Preliminary Tests For Development Of A Non-Pertechnetate Analysis Method
DOE Office of Scientific and Technical Information (OSTI.GOV)
Diprete, D.; McCabe, D.
2016-09-28
The objective of this task was to develop a non-pertechnetate analysis method that 222-S lab could easily implement. The initial scope involved working with 222-S laboratory personnel to adapt the existing Tc analytical method to fractionate the non-pertechnetate and pertechnetate. SRNL then developed and tested a method using commercial sorbents containing Aliquat ® 336 to extract the pertechnetate (thereby separating it from non-pertechnetate), followed by oxidation, extraction, and stripping steps, and finally analysis by beta counting and Mass Spectroscopy. Several additional items were partially investigated, including impacts of a 137Cs removal step. The method was initially tested on SRS tankmore » waste samples to determine its viability. Although SRS tank waste does not contain non-pertechnetate, testing with it was useful to investigate the compatibility, separation efficiency, interference removal efficacy, and method sensitivity.« less
Harden, R. McG.; Alexander, W. D.; Shimmins, J.; Chisholm, D.
1969-01-01
The concentration of iodide (I−) and pertechnetate (TcO4−) and bromide (Br−) has been measured simultaneously in gastric juice and parotid saliva. The combined gastric and salivary clearance for iodide and pertechnetate is more than twice the clearance of these ions by the thyroid gland. The concentration of the ions was in the order I−>TcO4−>Br− in both gastric juice and saliva. Differences exist between the secretion of iodide, pertechnetate, and bromide. Bromide, in contrast to iodide and pertechnetate, was found to be more concentrated in gastric juice than in saliva. The ratio of the iodide to pertechnetate clearance was greater in gastric juice than in saliva. PMID:5358585
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kenneth R. Ashely; Norman Schroeder; Jose A. Olivares
2004-12-10
This proposal had three major goals: (1) develop capillary electrophoresis mass spectrometry as a characterization technique, (2) separate a non-pertechnetate fraction from a waste sample and identify the non-pertechnetate species in it by CEMS, and (3) synthesize and characterize bulk quantities of the identified non-pertechnetate species and study their ligand substitution and redox chemistry.
Uchida, Toyoyoshi; Suzuki, Ruriko; Kasai, Takatoshi; Onose, Hiroyuki; Komiya, Koji; Goto, Hiromasa; Takeno, Kageumi; Ishii, Shinya; Sato, Junko; Honda, Akira; Kawano, Yui; Himuro, Miwa; Yamada, Emiko; Yamada, Tetsu; Watada, Hirotaka
2016-01-01
Thyroid uptake of (99m)Tc-pertechnetate is a useful way to determine the cause of thyrotoxicosis. In daily clinical practice, (99m)Tc-pertechnetate uptake is used to discriminate between Graves' disease and painless thyroiditis when clinical information is not enough to make the distinction. However, since the optimal cutoff value of (99m)Tc-pertechnetate uptake has not yet been elucidated, our aim was to determine this value. We recruited patients with thyrotoxicosis in whom (99m)Tc-pertechnetate uptake was measured in clinical settings between 2009 and 2013. Three experienced endocrinologists (who were blinded to the value of (99m)Tc-pertechnetate uptake and initial treatment) diagnosed the cause of thyrotoxicosis based on thyrotropin, free triiodothyronine, free thyroxine, and thyrotropin receptor antibody levels, and by ultrasound findings and using images of thyroid uptake of (99m)Tc-pertechnetate without the actual values. Ninety-four patients diagnosed as having Graves' disease or painless thyroiditis were finally included. According to the diagnosis, the optimal cutoff value of (99m)Tc-pertechnetate uptake was determined by receiver operating characteristics analysis. A cutoff value of 1.0% provided optimal sensitivity and specificity of 96.6% and 97.1%, respectively. Then, its validity was confirmed in 78 patients with confirmed Graves' disease or painless thyroiditis diagnosed at another institute. Applying this cutoff value to the patients with thyrotoxicosis revealed positive and negative predictive values for Graves' disease of 100% and 88.9%, respectively. In conclusion, a cutoff value for (99m)Tc-pertechnetate uptake of 1.0% was useful to discriminate between Graves' disease and painless thyroiditis.
Mammary gland uptake of sodium Tc-pertechnetate in a cat with a drug-induced gynecomastia.
Patricelli, A J; Lappin, M R; Steyn, P F
1999-01-01
Sodium Tc-pertechnetate accumulated in the mammary glands of a male cat. It was determined that the uptake was attributable to gynecomastia induced by medroxyprogesterone acetate injections. Gynecomastia and pertechnetate uptake resolved following cessation of medroxyprogesterone acetate treatment.
Incidental Warthin Tumor on Pertechnetate Scintigraphy.
Kulkarni, Mukta; Shetkar, Shubhangi; Joshi, Prathamesh; Kasaliwal, Sanket; Chaudhari, Shrikant
2016-09-01
A 30-year-old woman underwent Tc-pertechnetate scintigraphy for evaluation of thyrotoxicosis. The scintigraphy revealed hypervascular thyroid gland with markedly increased trapping function in both the lobes suggesting diagnosis of Graves disease. Incidentally, a hypervascular and pertechnetate avid focus was seen along the lateral margin of the right parotid gland. Pertechnetate avidity and site of uptake suggested possibility of Warthin tumor. Clinical examination and ultrasonography revealed a well-defined lesion in the superficial lobe of the right parotid gland favoring diagnosis of benign lesion. Postsurgery specimen confirmed diagnosis of Warthin tumor.
Motoori, Ken; Ueda, Takuya; Uchida, Yoshitaka; Chazono, Hideaki; Suzuki, Homare; Ito, Hisao
2005-01-01
The aim of this study was to evaluate the accuracy of technetium-99m (Tc-99m) pertechnetate scintigraphy and magnetic resonance (MR) imaging in the diagnosis of Warthin tumor. Sixteen cases of Warthin tumor and 17 cases of non-Warthin tumor were examined by Tc-99m pertechnetate scintigraphy with lemon juice stimulation and MR imaging, including T1-weighted, T2-weighted, short inversion time inversion recovery, diffusion-weighted, and contrast-enhanced dynamic images. We used the receiver operating characteristic (ROC) curve to evaluate diagnostic accuracy. The mean area under the ROC curves of MR imaging in the diagnosis of Warthin tumor (0.97) was higher than that of Tc-99m pertechnetate scintigraphy (0.88). Magnetic resonance imaging is more useful in the evaluation of Warthin tumor than Tc-99m pertechnetate scintigraphy.
Ozdemir, Didem; Cuhaci, Fatma N; Ozdemir, Elif; Aydin, Cevdet; Ersoy, Reyhan; Turkolmez, Seyda; Cakir, Bekir
2016-06-01
Surgery and radioactive iodine (RAI) ablation constitute the mainstay of the treatment of differentiated thyroid carcinoma (DTC). In this study, we aimed to evaluate the diagnostic value of postoperative early Tc-99m pertechnetate scanning to detect remnant thyroid tissue and predict ablation success. DTC patients evaluated with postoperative Tc-99m pertechnetate scintigraphy and treated with RAI between January 2007 and December 2014 were recruited. The results of Tc-99m pertechnetate scanning were compared with therapeutic I-131 whole-body scanning (TxWBS) and diagnostic I-131 whole-body scanning (DxWBS) performed 6-9 months after RAI. There were 154 (21.5%) male and 563 (78.5%) female patients, with a mean age of 49.11±12.35 years. Postoperative Tc-99m pertechnetate scanning was positive in 499 patients (69.6%) and negative in 218 (30.4%) patients. There were 673 (93.9%) patients with a positive TxWBS scan and 44 (6.1%) patients with negative TxWBS scan. Considering TxWBS as the standard test, sensitivity, specificity, positive predictive value, and negative predictive value of Tc-99m pertechnetate scanning were 72.2, 70.5, 97.4, and 14.2%, respectively. DxWBS was positive in 57 (9.0%) and negative in 564 (91%) patients. Ablation dose was higher and preablation thyroglobulin was lower in patients with negative DxWBS (P=0.001 and 0.04, respectively). Overall, 171 (92.9%) of 184 patients with negative Tc-99m pertechnetate had negative DxWBS. Postoperative Tc-99m pertechnetate scintigraphy has a high positive predictive value to detect remnant tissue in patients with DTC. Although negative Tc-99m pertechnetate scanning does not indicate removal of all thyroid tissue, it is related to successful ablation in more than 90% of patients.
Speciation and Oxidative Stability of Alkaline Soluble, Non-Pertechnetate Technetium
DOE Office of Scientific and Technical Information (OSTI.GOV)
Levitskaia, Tatiana G.; Rapko, Brian M.; Anderson, Amity
2014-09-30
The long half-life, complex chemical behavior in tank waste, limited incorporation in mid- to high-temperature immobilization processes, and high mobility in subsurface environments make technetium (Tc) one of the most difficult contaminants to dispose of and/or remediate. Technetium exists predominantly in the liquid tank waste phase as the relatively mobile form of pertechnetate, TcO 4 -. However, based on experimentation to date a significant fraction of the soluble Tc cannot be effectively separated from the wastes and may be present as a non- pertechnetate species. The presence of a non-pertechnetate species significantly complicates disposition of low-activity waste (LAW), and themore » development of methods to either convert them to pertechnetate or to separate directly is needed. The challenge is the uncertainty regarding the chemical form of the alkaline-soluble low-valent non-pertechnetate species in the liquid tank waste. This report summarizes work done in fiscal year (FY) 2014 exploring the chemistry of a low-valence technetium(I) species, [(CO) 3Tc(H 2O) 3] +, a compound of interest due to its implication in the speciation of alkaline-soluble technetium in several Hanford tank waste supernatants.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
James, A.E. Jr.; Strecker, E.P.; Miller, F.J. Jr.
1975-07-01
Recent communications have related the diagnosis of small bowel intussusceptions to abnormal accumulations of the radiopharmaceutical /sup 99m/Tc pertechnetate on abdominal scans. Considering the pathophysiological alterations attendant to intussusceptions, we have attempted an experimental model to examine these changes in temporal sequence. This study was initiated to understand the etiology better and to characterize the abnormalities noted on the /sup 99m/Tc pertechnetate abdominal scans.
Oxidative Stability of Tc(I) Tricarbonyl Species Relevant to the Hanford Tank Waste
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chatterjee, Sayandev; Hall, Gabriel B.; Levitskaia, Tatiana G.
Technetium (Tc), which exists predominately in the liquid supernatant and salt cake fractions of the nuclear tank waste stored at the U.S. DOE Hanford Site, is one of the most difficult contaminants to dispose of and/or remediate. In the strongly alkaline environments prevalent in the tank waste, its dominant chemical form is pertechnetate (TcO 4 -, oxidation state +7). However, based on experimentation to-date, a significant fraction of the soluble Tc cannot be effectively separated from the wastes and may be present as a non-pertechnetate species. The presence of a non pertechnetate species significantly complicates disposition of low-activity waste (LAW),more » and the development of methods to either convert them to pertechnetate or to separate the non-pertechnetate species directly is needed. The challenge is the uncertainty regarding the nature and stability of the alkaline-soluble, low-valence, non pertechnetate species in the liquid tank waste. One objective of the Tc management project is to address this knowledge gap. This fiscal year (FY) 2015 report summarizes experimental work exploring the oxidative stability of model low-valence Tc(I) tricarbonyl species, derived from the [Tc(CO) 3] + moiety. These compounds are of interest due to their implied presence in several Hanford tank waste supernatants. Work in part was initiated in FY 2014, and a series of samples containing non-pertechnetate Tc generated ex situ or in situ in pseudo-Hanford tank supernatant simulant solutions was prepared and monitored for oxidation to Tc(VII) (Levitskaia et al. 2014). This experimentation continued in FY 2015, and new series of samples containing Tc(I) as [Tc(CO) 3] +•Ligand was tested. The monitoring method used for these studies was a combination of 99Tc NMR and EPR spectroscopies.« less
Gao, Rui; Gao, Shan; Feng, Jinteng; Wang, Yuanbo; Zhang, Guangjian
2017-09-01
Possible thyroiditis was suspected in a 56-year-old man who initially presented sore throat because laboratory examinations revealed decreased serum thyroid hormone and the Tc-pertechnetate scintigraphy showed no tracer uptake by the thyroid gland. However, subsequent examination demonstrated that the absence of pertechnetate activity in the thyroid was due to complete replacement of thyroid gland by the metastasis from lung adenocarcinoma, which was unknown at the initial presentation.
Vattimo, A; Bertelli, P; Burroni, L
1992-01-01
Baseline 99mTc-MIBI thyroid scintigraphy was compared with 99mTc-pertechnetate scintigraphy after TSH stimulation in seven patients with suppressed thyroid tissue due to an autonomously functioning thyroid nodule (AFTN). In all patients the suppressed thyroid tissue was visualized by means of both baseline 99mTc-MIBI and post-TSH 99mTc-pertechnetate scintigraphy, and in some cases the former technique provided better visualization. In one patient presenting a "warm" nodule T3-suppression did not affect the nodular/extranodular uptake ratio of 99mTc-MIBI, whereas the 99mTc-pertechnetate uptake ratio increased significantly. This leads us to hypothesize that the thyroid uptake of 99mTc-MIBI is not related to TSH control, but rather to other mechanisms such as the blood flow. Since exogenous TSH is no longer available, 99mTc-MIBI scintigraphy can be successfully used in the place of repeated 99mTc-pertechnetate scintigraphy after TSH stimulation in the assessment of AFTN.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Banerjee, Debasis; Elsaidi, Sameh K.; Aguila, Briana
2016-10-20
Efficient and cost-effective removal of radioactive pertechnetate anions from nuclear waste is a key challenge to mitigate long-term nuclear waste storage issues. Traditional materials such as resins and layered double hydroxides (LDHs) were evaluated for their pertechnetate or perrhenate (the non-radioactive surrogate) removal capacity, but there is room for improvement in terms of capacity, selectivity and kinetics. A series of functionalized hierarchical porous frameworks were evaluated for their perrhenate removal capacity in the presence of other competing anions.
Spectroscopic Properties of Tc(I) Tricarbonyl Species Relevant to the Hanford Tank Waste
DOE Office of Scientific and Technical Information (OSTI.GOV)
Levitskaia, Tatiana G.; Andersen, Amity; Chatterjee, Sayandev
2015-12-04
Technetium-99 (Tc) exists predominately in soluble forms in the liquid supernatant and salt cake fractions of the nuclear tank waste stored at the U.S. DOE Hanford Site. In the strongly alkaline environments prevalent in the tank waste, its dominant chemical form is pertechnetate (TcO4-, oxidation state +7). However, attempts to remove Tc from the Hanford tank waste using ion-exchange processes specific to TcO 4 - only met with limited success, particularly processing tank waste samples containing elevated concentrations of organic complexants. This suggests that a significant fraction of the soluble Tc can be present as non-pertechnetate low-valent Tc (oxidation statemore » < +7) (non-pertechnetate). The chemical identities of these non-pertechnetate species are poorly understood. Previous analysis of the SY-101 and SY-103 tank waste samples provided strong evidence that non-pertechnetate can be comprised of [Tc(CO) 3] + complexes containing Tc in oxidation state +1 (Lukens et al. 2004). During the last two years, our team has expanded this work and demonstrated that high-ionic-strength solutions typifying tank waste supernatants promote oxidative stability of the [Tc(CO) 3] + species (Rapko et al. 2013; Levitskaia et al. 2014). It also was observed that high-ionic-strength alkaline matrices stabilize Tc(VI) and potentially Tc(IV) oxidation states, particularly in presence organic chelators, suggesting that the relevant Tc compounds can serve as important redox intermediates facilitating the reduction of Tc(VII) to Tc(I). Designing strategies for effective Tc processing, including separation and immobilization, necessitates understanding the molecular structure of these non-pertechnetate species and their identification in the actual tank waste samples. To-date, only limited information exists regarding the nature and characterization of the Tc(I), Tc(IV), and Tc(VI) species. One objective of this project is to identify the form of non-pertechnetate in the Hanford waste. To do this, we are developing a spectral library of reference non-pertechnetate compounds that can be compared against actual waste samples. The emphasis of the fiscal year 2015 work was Tc(I) tricarbonyl [Tc(CO) 3] + compounds. The key findings are summarized below.« less
Sarkar, S K; Saraswathy, P; Arjun, G; Ramamoorthy, N
2004-06-01
Newer applications of radiopharmaceuticals in nuclear medicine require pertechnetate of moderate to high radioactive concentration. Hence there is a need to develop simple procedures for the concentration of pertechnetate, and such a procedure is given in this paper. Ten to 20 ml of sodium [Tc]pertechnetate eluted in de-ionized water from a zirconium [Mo]molybdate (ZrMo) gel column generator was passed through 2 g of an acidic alumina bed (35 x 8 mm) in order to remove the co-eluted traces of Mo and to retain the pertechnetate. The retained pertechnetate was then re-eluted, quantitatively, in 3 ml of normal saline, from the alumina column. About a 4-fold increase in radioactive concentration of Tc was obtained (cf. approximately 10-12 ml normal saline is required for the elution of Tc from the gel column). Generators containing up to 22.2 GBq (600 mCi) Mo in 6-7 g ZrMo gel column (35 x 13 mm) were prepared and a radioactive concentration of Tc up to 4 GBq x ml (110 mCi x ml) was obtained on the first day of use. The overall recovery of Tc was >90%, Mo breakthrough was 10 to 10% and the duration of concentration was 3-5 min. The chemical impurity in terms of Al, Mo and Zr was <10 ppm each. The same procedure for the concentration of pertechnetate was applied to generators with 12-15 g ZrMo gel beds to obtain a higher capacity Tc gel generator, with similar findings.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Berquist, T.H.; Nolan, N.G.; Stephens, D.H.
1976-06-01
Numerous reports in the recent literature have questioned the value of abdominal scanning with pertechnetate in the diagnosis of Meckel's diverticulum. In an attempt to evaluate further the specificity of pertechnetate in this condition, the clinical data and scintigrams of 100 patients with suspected Meckel's diverticulum were reviewed. The scintigram correctly identified Meckel's diverticulum before operation in seven of eight patients. One false-negative study occurred in 33 patients who underwent laparotomy. Conditions suggested as possible causes of false-positive studies (hydronephrosis, arteriovenous malformations, and intussusception) were found to give negative scans. (auth)
van Hoek, Ingrid M; Peremans, Kathelijne; Vandermeulen, Eva; Duchateau, Luc; Gommeren, Kris; Daminet, Sylvie
2009-04-01
This study investigated the thyroidal response to administration of recombinant human thyroid stimulating hormone (rhTSH) by means of serum total thyroxine (TT(4)) concentration and pertechnetate uptake by the thyroid gland in six healthy euthyroid spayed female cats. A pertechnetate scan was performed on day 1 to calculate thyroid/salivary gland (T/S) uptake ratio. On day 3, 25 microg rhTSH was injected intravenously. Six hours later the thyroid scan was repeated as on day 1. Blood was drawn for serum TT(4) measurement prior to injection of rhTSH and performance of the pertechnetate scan. Statistically significant differences in mean serum TT(4) concentration, T/S uptake ratio before and 6h after rhTSH administration and T/S uptake ratio between left and right lobes were noted. We can conclude that 25 microg rhTSH increases pertechnetate uptake in the thyroid glands of cats, this should be taken into account when thyroid scintigraphy after rhTSH administration is interpreted.
Drout, Riki J.; Otake, Kenichi; Howarth, Ashlee J.; ...
2018-01-10
At the Hanford Site in southeastern Washington state, the U.S. Department of Energy intends to treat 56 million gallons of legacy nuclear waste by encasing it in borosilicate glass via vitrification. This process ineffectively captures radioactive pertechnetate (TcO 4–) because of the ion’s volatility, thereby requiring a different remediation method for this long-lived (t 1/2 = 2.1 × 10 5 years), environmentally mobile species. Currently available sorbents lack the desired combination of high uptake capacity, fast kinetics, and selectivity. Here, we evaluate the ability of the chemically and thermally robust Zr 6-based metal–organic framework (MOF), NU-1000, to capture perrhenate (ReOmore » 4–), a pertechnetate simulant, and pertechnetate. Our material exhibits an excellent perrhenate uptake capacity of 210 mg/g, reaches saturation within 5 min, and maintains perrhenate uptake in the presence of competing anions. Additionally, experiments with pertechnetate confirm perrhenate is a suitable surrogate. Single-crystal X-ray diffraction indicates both chelating and nonchelating perrhenate binding motifs are present in both the small pore and the mesopore of NU-1000. Postadsorption diffuse reflectance infrared Fourier transform spectroscopy (DRIFTS) further elucidates the uptake mechanism and powder X-ray diffraction (PXRD) and Brunauer–Emmett–Teller (BET) surface area analysis confirm the retention of crystallinity and porosity of NU-1000 throughout adsorption.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hall, Gabriel B.; Chatterjee, Sayandev; Levitskaia, Tatiana G.
Among long-lived radioactive constituents in the Hanford tank waste, Tc presents a unique challenge in that it exists predominantly in the liquid phase, generally in the anionic form of pertechnetate, TcO 4 -, which is highly volatile at low-activity waste (LAW) vitrification melter temperatures and mobile in the Hanford site’s subsurface environment. The complex behavior of Tc under storage, treatment, and immobilization conditions significantly affects its management options, which to-date remain uncertain. In strongly alkaline environments, Tc exists as pertechnetate, TcO 4 - (oxidation state +7), and in the reduced forms (oxidation state < +7) collectively known as non-pertechnetate species.more » Pertechnetate is a well-characterized, anionic Tc species that can be removed from LAW by anion exchange or solvent extraction methods. There is no definitive information on the origin of the non-pertechnetate Tc species, nor is there a comprehensive description of their composition and behavior. It has been recently proposed that the non-pertechnetate species can comprise Tc(I) metal center and carbonyl or mixed carbonyl nitrosyl ligands stabilizing low-valent Tc. Recent work by our group has significantly expanded this previous work, generating a series of Tc(I) carbonyl compounds and demonstrating that they can be generated from reduction of TcO 4 - in the simulated Hanford tank waste in presence of CO at elevated temperature (Levitskaia et al. 2014). These results are consistent with the previous proposal that [Tc(CO) 3] + species can be present in the Hanford tank waste and suggest that the low Tc(I) oxidation state is stabilized by the π-accepting ability of the CO ligands. The continuation work has been initiated to develop model Tc carbonyl nitrosyl compounds and investigate their potential presence in the Hanford tank wastes. This report summarizes our to-date results.« less
Andersson, J D; Wilson, J S; Romaniuk, J A; McEwan, A J B; Abrams, D N; McQuarrie, S A; Gagnon, K
2016-04-01
Hydrophobic adsorbents such as C18 and C30 were coated with PEG and subsequently used for the separation of Mo/Tc. The most effective resin for adsorbing PEG was the C18-U resin, which demonstrated a coating capacity of 97.6±2.8mg PEG per g of resin. The ability to adsorb pertechnetate was proportional to the amount of PEG coated on the hydrophobic resin. The [(99m)Tc]pertechnetate recovery during the separation of cyclotron produced (99m)Tc from (100)Mo was 91.8±0.3% (n=2). The resultant product met relevant USP monograph specifications. Copyright © 2016 Elsevier Ltd. All rights reserved.
Non-pertechnetate Technetium Sensor Research and Development
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bryan, Samuel A.; Rapko, Brian M.; Branch, Shirmir D.
Several significant uncertainties remain regarding the understanding and modeling of the fate and speciation of technicium-99 ( 99Tc) in Hanford waste tanks, glass, and low-temperature waste forms. A significant (2% to 25%) fraction of the 99Tc in the water-soluble portion of the tank waste may be present as one or more non pertechnetate species that have not been identified and to date, cannot be effectively separated from the wastes. This task will provide a sensor specifically tuned to detect the Tc(I)-carbonyl species believed to constitute the main fraction of the non-pertechnetate form of technetium. By direct measurement of the non-pertechnetatemore » species, such a sensor will help reduce the uncertainties in the modeling of the fate and speciation of 99Tc in Hanford tanks and waste forms. This report summarizes work performed in FY2016 that was sponsored by the Department of Energy’s Office of Environmental Management and demonstrates the protocol for using fluorescent Tc(I)-tricarbonyl complex as a means to detect the non-pertechnetate species within tank waste solutions. The protocol was optimized with respect to ligand concentration, solvent choice, reaction temperature and time. This work culminated in the quantitation of Tc(I)-tricarbonyl within a waste simulant, using a standard addition method for measurement. This report also summarizes the synthesis and high-yield preparation of the low-valence technetium species, [Tc(CO) 3(H 2O) 3] +, which will be used as the technetium standard material for the demonstration of the non-pertechnetate species in actual wastes.« less
dell'Erba, L; Gerundini, P; Caputo, M; Bagnasco, M
2003-11-01
Rarely may a non-hyperfunctioning thyroid nodule present as "hot" at Technetium-99m pertechnetate (99mTcO4-) and "cold" at radioiodine scintigraphy at late acquisitions. We report the case of a hyperthyroid female patient whose 99mTcO4- scintigraphy showed two "hot" nodules, whereas Iodide-131 (131I-) revealed a lack of indicator uptake by the larger, and intense uptake by the smaller nodule. The patient underwent surgery: histology demonstrated that the larger nodule, mismatched at pertechnetate vs iodine scintigraphy, was a papillary carcinoma. Our suggestion is to perform thyroid scintigraphy with radioiodine in hyperthyroid patients with more than one nodule concentrating pertechnetate, especially when an ultrasonographic pattern possibly suspect for malignancy is present.
Synthesis and Characterization of 5- and 6- Coordinated Alkali Pertechnetates
DOE Office of Scientific and Technical Information (OSTI.GOV)
Weaver, Jamie; Soderquist, Chuck; Gassman, Paul
ABSTRACT The local chemistry of technetium-99 ( 99Tc) in oxide glasses is important for understanding the incorporation and long-term release of Tc from nuclear waste glasses, both those for legacy defense wastes and fuel reprocessing wastes. Tc preferably forms Tc(VII), Tc(IV), or Tc(0) in glass, depending on the level of reduction of the melt. Tc(VII) in oxide glasses is normally assumed to be isolated pertechnetate TcO 4 -anions surrounded by alkali, but can occasionally precipitate as alkali pertechnetate salts such as KTcO 4and NaTcO 4when Tc concentration is high. In these cases, Tc(VII) is 4-coordinated by oxygen. A reinvestigation ofmore » the chemistry of alkali-technetium-oxides formed under oxidizing conditions and at temperatures used to prepare nuclear waste glasses showed that higher coordinated alkali Tc(VII) oxide species had been reported, including those with the TcO 5 -and TcO 6 -anions. The chemistry of alkali Tc(VII) and other alkali-Tc-oxides is reviewed, along with relevant synthesis conditions. Additionally, we report attempts to make 5- and 6-coordinate pertechnetate compounds of K, Na, and Li, i.e. TcO 5 -and TcO 6 -. It was found that higher coordinated species are very sensitive to water, and easily decompose into their respective pertechnetates. It was difficult to obtain pure compounds, but mixtures of the pertechnetate and other phase(s) were frequently found, as evidenced by x-ray absorption spectroscopy (XAS), neutron diffraction (ND), and Raman spectroscopy. Low temperature electron paramagnetic resonance (EPR) measurements showed the possibility of Tc(IV) and Tc(VI) in Na 3TcO 5and Na 5TcO 6compounds. It was hypothesized that the smaller counter cation would result in more stable pertechnetates. To confirm the synthesis method, LiReO 4and Li 5ReO 6were prepared, and their Raman spectra match those in the literature. Subsequently, the Tc versions LiTcO 4and Li 5TcO 6were synthesized and characterized by ND, Raman spectroscopy, XANES, and EXAFS. The Li 5TcO 6was a marginally stable compound that appears to have the same structure as that known for Li 5ReO 6. Implications of the experimental work on stability of alkali technetate compounds and possible role in the volatilization of Tc are discussed.« less
Characterization of Non-pertechnetate Species Relevant to the Hanford Tank Waste
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chatterjee, Sayandev; Andersen, Amity; Du, Yingge
Among radioactive constituents present in the tank waste stored at the U.S. DOE Hanford Site, technetium-99 (Tc), which is generated from the fission of 235U and 239Pu in high yields, presents a unique challenge in that it has a long half-life ( = 292 keV; T1/2 = 2.11105 y) and exists predominately in soluble forms in the liquid supernatant and salt cake fractions of the waste. In the strongly alkaline environments prevalent in most of the tank waste, its dominant chemical form is pertechnetate (TcO 4 -, oxidation state +7). However, attempts to remove Tc from the Hanford tank wastemore » using ion-exchange processes specific to TcO 4 - only met with limited success, particularly when processing tank waste samples containing elevated concentrations of organic complexants. This suggests that a significant fraction of the soluble Tc can be present as low-valent Tc (oxidation state < +7) (non-pertechnetate). The chemical identities of these non-pertechnetate species are poorly understood. Previous analysis of the SY-101 and SY-103 tank waste samples provided strong evidence that non-pertechnetate can be comprised of [fac-Tc(CO) 3] + complexes containing Tc in oxidation state +1 (Lukens et al. 2004). During the last three years, our team has expanded this work and demonstrated that high-ionic-strength solutions typifying tank waste supernatants promote oxidative stability of the [fac-Tc(CO) 3] + species (Rapko et al. 2013a; 2013b; Levitskaia et al. 2014; Chatterjee et al. 2015). Obtained results also suggest possible stabilization of Tc(VI) and potentially Tc(IV) oxidation states in the high-ionic-strength alkaline matrices particularly in the presence of organic chelators, so that Tc(IV, VI) can serve as important redox intermediates facilitating the reduction of Tc(VII) to Tc(I). Designing strategies for effective Tc management, including separation and immobilization, necessitates understanding the molecular structure of the non-pertechnetate species and their identification in the actual tank waste samples, which would facilitate development of new treatment technologies effective for dissimilar Tc species. The key FY 2016 results are summarized below.« less
In Situ Bioremediation of Perchlorate in Vadose Zone Soil Using Gaseous Electron Donors
2009-11-01
National Aeronautics and Space Administration ND Non-detect NDMA N-Nitrosodimethylamine No. Number NO3- Nitrate OD Outside diameter O&M...Nitrite xv • Selenate • Arsenate • Chromate and dichromate (i.e., hexavalent chromium) • Uranylate • Pertechnetate • N-Nitrosodimethylamine ( NDMA ...Arsenate • Chromate and dichromate (i.e., hexavalent chromium) • Uranylate • Pertechnetate • N-Nitrosodimethylamine ( NDMA ) • Trichloroethene (TCE
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bunker, S.R.; Kolina, J.S.; Kaplan, K.A.
1983-05-01
Scintigraphy with RBCs labeled with technetium Tc 99m sodium pertechnetate effectively located the source of hemorrhage in a patient receiving long-term anticoagulant therapy. (The patient was initially seen with a large hematoma on the flank.) More important, the procedure was used to monitor activity in this otherwise-occult bleeding site. Scintigraphic studies may be useful in the management of these difficult clinical problems.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Weaver, Jamie; Soderquist, Chuck; Gassman, Paul
The local chemistry of technetium-99 ( 99Tc) in oxide glasses is important for understanding the incorporation and long-term release of Tc from nuclear waste glasses, both those for legacy defense wastes and fuel reprocessing wastes. Tc preferably forms Tc(VII), Tc(IV), or Tc(0) in glass, depending on the level of reduction of the melt. Tc(VII) in oxide glasses is normally assumed to be isolated pertechnetate TcO 4 -anions surrounded by alkali, but can occasionally precipitate as alkali pertechnetate salts such as KTcO 4and NaTcO 4when Tc concentration is high. In these cases, Tc(VII) is 4-coordinated by oxygen. A reinvestigation of themore » chemistry of alkali-technetium-oxides formed under oxidizing conditions and at temperatures used to prepare nuclear waste glasses showed that higher coordinated alkali Tc(VII) oxide species had been reported, including those with the TcO 5 -and TcO 6 -anions. The chemistry of alkali Tc(VII) and other alkali-Tc-oxides is reviewed, along with relevant synthesis conditions. Additionally, we report attempts to make 5- and 6-coordinate pertechnetate compounds of K, Na, and Li, i.e. TcO 5 -and TcO 6 -. It was found that higher coordinated species are very sensitive to water, and easily decompose into their respective pertechnetates. It was difficult to obtain pure compounds, but mixtures of the pertechnetate and other phase(s) were frequently found, as evidenced by x-ray absorption spectroscopy (XAS), neutron diffraction (ND), and Raman spectroscopy. Low temperature electron paramagnetic resonance (EPR) measurements showed the possibility of Tc(IV) and Tc(VI) in Na 3TcO 5and Na 5TcO 6compounds. It was hypothesized that the smaller counter cation would result in more stable pertechnetates. To confirm the synthesis method, LiReO 4and Li 5ReO 6were prepared, and their Raman spectra match those in the literature. Subsequently, the Tc versions LiTcO 4and Li 5TcO 6were synthesized and characterized by ND, Raman spectroscopy, XANES, and EXAFS. The Li 5TcO 6was a marginally stable compound that appears to have the same structure as that known for Li 5ReO 6. Implications of the experimental work on stability of alkali technetate compounds and possible role in the volatilization of Tc are discussed.« less
Gallium scanning in cerebral and cranial infections. [/sup 67/Ga, /sup 99m/Tc tracer techniques
DOE Office of Scientific and Technical Information (OSTI.GOV)
Waxman, A.D.; Siemsen, J.K.
1976-08-01
Eighteen patients with cranial or intracranial infections were studied with technetium and gallium brain scans. Seven of 18 lesions were noted with gallium and not with pertechnetate, while the reverse pattern was not seen. Brain abscesses were visualized with gallium but not with pertechnetate in two of five cases. Osteomyelitis of the skull and mastoiditis showed intense gallium uptake in all cases, while meningitis or cerebritis gave inconsistent results.
Detection of intestinal obstruction by radionuclide scan: case report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chaudhuri, T.K.
1976-11-01
The value of /sup 99m/Technetium-pertechnetate abdomen scan has recently been established in the diagnosis of Meckel's diverticulum, intussusception, and inflamed appendix. The purpose of this paper is to report a case with small intestinal obstruction secondary to fibrous adhesions which resulted from a previous surgery, in whom a /sup 99m/Technetium-pertechnetate abdomen scan showed increased radionuclide concentration in the area of dilated loop of bowel proximal to the site of obstruction.
Technetium 99m pertechnetate scans in congenital hypothyroidism
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bauman, R.A.; Bode, H.H.; Hayek, A.
1976-08-01
Goiters are rarely palpable in infants with congenital hypothyroidism except in the case of maternal ingestion of iodide. The presence or absence of glandular tissue is, however, important for genetic and prognostic counseling and for acceleration of diagnosis in other affected siblings. The detection of thyroid tissue by /sup 99m/Tc pertechnetate scans in a significant number of our patients heretofore considered athyreotic establishes that physical findings and traditional laboratory data are not adequate to determine whether or not thyroid tissue is present.
Selivanova, Svetlana V; Lavallée, Éric; Senta, Helena; Caouette, Lyne; Sader, Jayden A; van Lier, Erik J; Zyuzin, Alexander; van Lier, Johan E; Guérin, Brigitte; Turcotte, Éric; Lecomte, Roger
2015-10-01
Cyclotron production of 99mTc is a promising route to supply 99mTc radiopharmaceuticals. Higher 99mTc yields can be obtained with medium-energy cyclotrons in comparison to those dedicated to PET isotope production. To take advantage of this capability, evaluation of the radioisotopic purity of 99mTc produced at medium energy (20-24 MeV) and its impact on image quality and dosimetry was required. Thick 100Mo (99.03% and 99.815%) targets were irradiated with incident energies of 20, 22, and 24 MeV for 2 or 6 h. The targets were processed to recover an effective thickness corresponding to approximately 5-MeV energy loss, and the resulting sodium pertechnetate 99mTc was assayed for chemical, radiochemical, and radionuclidic purity. Radioisotopic content in final formulation was quantified using γ-ray spectrometry. The internal radiation dose for 99mTc-pertechnetate was calculated on the basis of experimentally measured values and biokinetic data in humans. Planar and SPECT imaging were performed using thin capillary and water-filled Jaszczak phantoms. Extracted sodium pertechnetate 99mTc met all provisional quality standards. The formulated solution for injection had a pH of 5.0-5.5, contained greater than 98% of radioactivity in the form of pertechnetate ion, and was stable for at least 24 h after formulation. Radioisotopic purity of 99mTc produced with 99.03% enriched 100Mo was greater than 99.0% decay corrected to the end of bombardment (EOB). The radioisotopic purity of 99mTc produced with 99.815% enriched 100Mo was 99.98% or greater (decay corrected to the EOB). The estimated dose increase relative to 99mTc without any radionuclidic impurities was below 10% for sodium pertechnetate 99mTc produced from 99.03% 100Mo if injected up to 6 h after the EOB. For 99.815% 100Mo, the increase in effective dose was less than 2% at 6 h after the EOB and less than 4% at 15 h after the EOB when the target was irradiated at an incident energy of 24 MeV. Image spatial resolution and contrast with cyclotron-produced 99mTc were equivalent to those obtained with 99mTc eluted from a conventional generator. Clinical-grade sodium pertechnetate 99mTc was produced with a cyclotron at medium energies. Quality control procedures and release specifications were drafted as part of a clinical trial application that received approval from Health Canada. The results of this work are intended to contribute to establishing a regulatory framework for using cyclotron-produced 99mTc in routine clinical practice. © 2015 by the Society of Nuclear Medicine and Molecular Imaging, Inc.
In vitro stabilization of a low-tin bone-imaging agent (99mTc-Sn-HEDP) by ascorbic acid.
Tofe, A J; Francis, M D
1976-09-01
The presence of oxidants in the 99mTc-pertechnetate and of oxygen in diagnostic kits containing low concentrations of Sn(II) has a detrimental effect upon in vitro and in vivo stability. Maintaining a nitrogen atmosphere or increasing the Sn(II) concentration inhibits the formation of 99mTcO4-. However, the latter remedy is likely to cause uptake in the reticuloendothelial system and has been associated with false positive or negative brain scans. We used ascorbic acid (an antioxidant) to ensure the in vitro stability with the low-Sn(II) bone agent disodium etidronate. In vitro stability studies by instant thin-layer chromatography, using high-acitivity generators and "instant pertechnetate," yielded less than 2% free pertechnetate at 24 hr after preparation. Distribution studies in guinea pigs show neither altered distribution of the bone agent nor abnormal distribution of ascorbic acid, suggesting its sole function as a noncomplexing stabilizer.
Chemical Trends in Solid Alkali Pertechnetates.
Weaver, Jamie; Soderquist, Chuck Z; Washton, Nancy M; Lipton, Andrew S; Gassman, Paul L; Lukens, Wayne W; Kruger, Albert A; Wall, Nathalie A; McCloy, John S
2017-03-06
Insight into the solid-state chemistry of pure technetium-99 ( 99 Tc) oxides is required in the development of a robust immobilization and disposal system for nuclear waste stemming from the radiopharmaceutical industry, from the production of nuclear weapons, and from spent nuclear fuel. However, because of its radiotoxicity and the subsequent requirement of special facilities and handling procedures for research, only a few studies have been completed, many of which are over 20 years old. In this study, we report the synthesis of pure alkali pertechnetates (sodium, potassium, rubidium, and cesium) and analysis of these compounds by Raman spectroscopy, X-ray absorption spectroscopy (XANES and EXAFS), solid-state nuclear magnetic resonance (static and magic angle spinning), and neutron diffraction. The structures and spectral signatures of these compounds will aid in refining the understanding of 99 Tc incorporation into and release from nuclear waste glasses. NaTcO 4 shows aspects of the relatively higher electronegativity of the Na atom, resulting in large distortions of the pertechnetate tetrahedron and deshielding of the 99 Tc nucleus relative to the aqueous TcO 4 - . At the other extreme, the large Cs and Rb atoms interact only weakly with the pertechnetate, have closer to perfect tetrahedral symmetry at the Tc atom, and have very similar vibrational spectra, even though the crystal structure of CsTcO 4 is orthorhombic while that of RbTcO 4 is tetragonal. Further trends are observed in the cell volume and quadrupolar coupling constant.
Chemical Trends in Solid Alkali Pertechnetates
Weaver, Jamie; Soderquist, Chuck Z.; Washton, Nancy M.; ...
2017-02-21
Insight into the solid-state chemistry of pure technetium-99 ( 99Tc) oxides is required in the development of a robust immobilization and disposal system for nuclear waste stemming from the radiopharmaceutical industry, from the production of nuclear weapons, and from spent nuclear fuel. However, because of its radiotoxicity and the subsequent requirement of special facilities and handling procedures for research, only a few studies have been completed, many of which are over 20 years old. In this study, we report the synthesis of pure alkali pertechnetates (sodium, potassium, rubidium, and cesium) and analysis of these compounds by Raman spectroscopy, X-ray absorptionmore » spectroscopy (XANES and EXAFS), solid-state nuclear magnetic resonance (static and magic angle spinning), and neutron diffraction. The structures and spectral signatures of these compounds will aid in refining the understanding of 99Tc incorporation into and release from nuclear waste glasses. NaTcO 4 shows aspects of the relatively higher electronegativity of the Na atom, resulting in large distortions of the pertechnetate tetrahedron and deshielding of the 99Tc nucleus relative to the aqueous TcO 4 –. At the other extreme, the large Cs and Rb atoms interact only weakly with the pertechnetate, have closer to perfect tetrahedral symmetry at the Tc atom, and have very similar vibrational spectra, even though the crystal structure of CsTcO 4 is orthorhombic while that of RbTcO 4 is tetragonal. Further trends are observed in the cell volume and quadrupolar coupling constant.« less
Page, Richard B; Scrivani, Peter V; Dykes, Nathan L; Erb, Hollis N; Hobbs, Jeff M
2006-01-01
Our purpose was to determine the accuracy of increased thyroid activity for diagnosing hyperthyroidism in cats suspected of having that disease during pertechnetate scintigraphy using subcutaneous rather than intravenous radioisotope administration. Increased thyroid activity was determined by two methods: the thyroid:salivary ratio (T:S) and visual inspection. These assessments were made on the ventral scintigram of the head and neck. Scintigraphy was performed by injecting sodium pertechnetate (111 MBq, SQ) in the right-dorsal-lumbar region; static-acquisition images were obtained 20 min after injection. We used 49 cats; 34 (69%) had hyperthyroidism based on serum-chemistry analysis. Using a Wilcoxon's rank-sum test, a significant difference (P < 0.0001) was detected in the T:S between cats with and without hyperthyroidism. Using a decision criterion of 2.0 for the T:S, the test accurately predicted hyperthyroidism in 32/34 cats (sensitivity, 94%; 95% confidence interval (CI), 85-100%) and correctly predicted that hyperthyroidism was absent in 15/15 cats (specificity, 100%; CI, 97-100%). Using visual inspection, the test accurately predicted hyperthyroidism in 34/34 cats (sensitivity, 100%; CI, 99-100%) and correctly predicted that hyperthyroidism was absent in 12/15 cats (specificity, 80%; CI, 56-100%). The positive and negative predictive values were high for a wide range of prevalence of hyperthyroidism. And, the test had excellent agreement within and between examiners. Therefore, detecting increased thyroid activity during pertechnetate scintigraphy by subcutaneous injection is an accurate and reproducible test for feline hyperthyroidism.
Pierce, Eric M.; Lilova, Kristina; Missimer, David M.; ...
2016-12-05
Here we report that treatment and immobilization of technetium-99 ( 99Tc) contained in reprocessed nuclear waste and present in contaminated subsurface systems represents a major environmental challenge. One potential approach to managing this highly mobile and long-lived radionuclide is immobilization into micro- and meso-porous crystalline solids, specifically sodalite. We synthesized and characterized the structure of perrhenate sodalite, Na 8[AlSiO 4]6(ReO 4) 2, and the structure of a mixed guest perrhenate/pertechnetate sodalite, Na 8[AlSiO 4] 6(ReO 4) 2-x(TcO 4) x. Perrhenate was used as a chemical analogue for pertechnetate. Bulk analyses of each solid confirm a cubic sodalite-type structure (Pmore » $$\\overline{43}$$n, No. 218 space group) with rhenium and technetium in the 7+ oxidation state. High-resolution nanometer scale characterization measurements provide first-of-a-kind evidence that the ReO 4 – anions are distributed in a periodic array in the sample, nanoscale clustering is not observed, and the ReO 4 – anion occupies the center of the sodalite β-cage in Na8[AlSiO4]6(ReO4)2. We also demonstrate, for the first time, that the TcO4– anion can be incorporated into the sodalite structure. Lastly, thermochemistry measurements for the perrhenate sodalite were used to estimate the thermochemistry of pertechnetate sodalite based on a relationship between ionic potential and the enthalpy and Gibbs free energy of formation for previously measured oxyanion-bearing feldspathoid phases. The results collected in this study suggest that micro- and mesoporous crystalline solids maybe viable candidates for the treatment and immobilization of 99Tc present in reprocessed nuclear waste streams and contaminated subsurface environments.« less
The effect of sodium pertechnetate human carbonic anhydrase I and II
NASA Astrophysics Data System (ADS)
Sahin, Ali; Senturk, Murat
2017-04-01
The inhibitory effects of Na99mTcO4 (Sodium pertechnetate) on human erythrocyte carbonic anhydrase I and II activity were investigated. For this purpose, hCA I was initially purified 114,29-fold at a yield of 69,19 % and hCA II was initially purified 710,82-fold at a yield of 71,72 % using sepharose 4B-tyrosine-sulfanilamide affinity gel chromatography. The in vitro effect of this compound on hCA I and II isoenzyme were studied. It was detected in in vitro studies that the hCA I and II enzymes are inhibited due to Na99mTcO4.
Volatile species of technetium and rhenium during waste vitrification
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kim, Dongsang; Kruger, Albert A.
Volatile loss of technetium (Tc) during vitrification of low-activity wastes is a technical challenge for treating and immobilizing the large volumes of radioactive and hazardous wastes stored at the U.S. Department of Energy's Hanford Site. There are various research efforts being pursued to develop technologies that can be implemented for cost effective management of Tc, including studies to understand the behavior of Tc during vitrification, with the goal of eventually increasing Tc retention in glass. Furthermore, one of these studies has focused on identifying the form or species of Tc and Re (surrogate for Tc) that evolve during the waste-to-glassmore » conversion process. This information is important for understanding the mechanism of Tc volatilization. In this paper, available information collected from the literature is critically evaluated to clarify the volatile species of Tc and Re and, more specifically, whether they volatilize as alkali pertechnetate and perrhenate or as technetium and rhenium oxides after decomposition of alkali pertechnetate and perrhenate. The evaluated data ranged from mass spectrometric identification of species volatilized from pure and binary alkali pertechnetate and perrhenate salts to structural and chemical analyses of volatilized materials during crucible melting and scaled melter processing of simulated wastes.« less
Calculation and usage of the thyroid to background ratio on the pertechnetate thyroid scan.
Wallack, Seth; Metcalf, Michelle; Skidmore, Angela; Lamb, Christopher R
2010-01-01
Feline hyperthyroidism is a common endocrine disorder. A single dose of 148MBq (4mCi) 131I is 95-98% effective for the treatment of hyperthyroidism in cats; however, the cause for treatment failures has not been determined. In a series of 113 hyperthyroid cats having pertechnetate thyroid scintigraphy before treatment using a standard 148MBq (4mCi) 131I dose, the thyroid to salivary gland (T:S) ratio and the thyroid to background (T:B) ratio were calculated. Results in 107 (95%) cats successfully treated were compared with results in six (5%) cats that remained hyperthyroid after treatment. T:B ratio was significantly higher for cats that had treatment failure (median 13.0, range 3.6-73.0) than for cats successfully treated (median 4.4, range 1.2-69.0) (P = 0.02), whereas there was no significant difference in their T:S ratios (P = 0.2). The T:B ratio is a new approach to evaluating the thyroid pertechnetate scan with the intent of identifying which hyperthyroid cats may fail treatment using a standard 148 MBq (4 mCi) 131 dose and which, therefore, require a higher dose.
Volatile species of technetium and rhenium during waste vitrification
Kim, Dongsang; Kruger, Albert A.
2017-10-26
Volatile loss of technetium (Tc) during vitrification of low-activity wastes is a technical challenge for treating and immobilizing the large volumes of radioactive and hazardous wastes stored at the U.S. Department of Energy's Hanford Site. There are various research efforts being pursued to develop technologies that can be implemented for cost effective management of Tc, including studies to understand the behavior of Tc during vitrification, with the goal of eventually increasing Tc retention in glass. Furthermore, one of these studies has focused on identifying the form or species of Tc and Re (surrogate for Tc) that evolve during the waste-to-glassmore » conversion process. This information is important for understanding the mechanism of Tc volatilization. In this paper, available information collected from the literature is critically evaluated to clarify the volatile species of Tc and Re and, more specifically, whether they volatilize as alkali pertechnetate and perrhenate or as technetium and rhenium oxides after decomposition of alkali pertechnetate and perrhenate. The evaluated data ranged from mass spectrometric identification of species volatilized from pure and binary alkali pertechnetate and perrhenate salts to structural and chemical analyses of volatilized materials during crucible melting and scaled melter processing of simulated wastes.« less
Sarkar, Sishir Kumar; Kothalkar, Chetan; Naskar, Prabhakar; Joshi, Sangeeta; Saraswathy, Padmanabhan; Dey, Arun Chandra; Vispute, Gunvant Leeladhar; Murhekar, Vishwas Vinayak; Pilkhwal, Neelam
2013-01-01
Purpose of the Study: The indigenous design and technology development for processing large scale zirconium molybdate-Mo-99 (ZrMo-99) Geltech generator was successfully commissioned in Board of Radiation and Isotope Technology (BRIT), India, in 2006. The generator production facility comprises of four shielded plant facilities equipped with tongs and special process gadgets amenable for remote operations for radiochemical processing of ZrMo-99 gel. Results: Over 2800 Geltech generators have been processed and supplied to user hospitals during the period 2006-2013. Geltech generator supplied by BRIT was initially not sterile. Simple elution of Tc-99m is performed by a sterile evacuated vial with sterile and pyrogen free 0.9% NaCl solution to obtain sodium (Tc-99m) pertechnetate solution. A special type online 0.22 μm membrane filter has been identified and adapted in Geltech generator. Conclusions: The online filtration of Tc-99m from Geltech generator; thus, provided sterile Tc-99m sodium pertechnetate solution. Generators assembled with modified filter assembly were supplied to local hospital in Mumbai Radiation Medicine Centre (RMC) and S.G.S. Medical College and KEM Hospital) and excellent performances were reported by users. PMID:24163509
Quality of 99mTcO4- from 99Mo Produced by 100Mo(n,2n)99Mo
NASA Astrophysics Data System (ADS)
Nagai, Yasuki; Nakahara, Yuto; Kawabata, Masako; Hatsukawa, Yuichi; Hashimoto, Kazuyuki; Saeki, Hideya; Motoishi, Shoji; Ohta, Akio; Shiina, Takayuki; Kawauchi, Yukimasa
2017-05-01
The pharmaceutical quality of 99mTc pertechnetate solution obtained from 99Mo, the 100Mo(n,2n) reaction product, was investigated for the first time with an emphasis on the nonradioactive Mo content and endotoxin concentration. They were less than the tolerance dose given in international guidelines and the established upper limit in an international pharmacopoeia, respectively. Four other quality control tests commonly used for a commercially available 99mTc pertechnetate solution also demonstrated to meet the United States Pharmacopeia requirements. The results strongly support that the thermochromatographic separation method used to separate 99mTc from 99Mo can be a promising substitute for the fission product 99Mo.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Weaver, Jamie; Soderquist, Chuck Z.; Washton, Nancy M.
Insight into the solid-state chemistry of pure technetium-99 ( 99Tc) oxides is required in the development of a robust immobilization and disposal system for nuclear waste stemming from the radiopharmaceutical industry, from the production of nuclear weapons, and from spent nuclear fuel. However, because of its radiotoxicity and the subsequent requirement of special facilities and handling procedures for research, only a few studies have been completed, many of which are over 20 years old. In this study, we report the synthesis of pure alkali pertechnetates (sodium, potassium, rubidium, and cesium) and analysis of these compounds by Raman spectroscopy, X-ray absorptionmore » spectroscopy (XANES and EXAFS), solid-state nuclear magnetic resonance (static and magic angle spinning), and neutron diffraction. The structures and spectral signatures of these compounds will aid in refining the understanding of 99Tc incorporation into and release from nuclear waste glasses. NaTcO 4 shows aspects of the relatively higher electronegativity of the Na atom, resulting in large distortions of the pertechnetate tetrahedron and deshielding of the 99Tc nucleus relative to the aqueous TcO 4 –. At the other extreme, the large Cs and Rb atoms interact only weakly with the pertechnetate, have closer to perfect tetrahedral symmetry at the Tc atom, and have very similar vibrational spectra, even though the crystal structure of CsTcO 4 is orthorhombic while that of RbTcO 4 is tetragonal. Further trends are observed in the cell volume and quadrupolar coupling constant.« less
Walker, Darrel D.; Ebra, Martha A.
1987-01-01
High efficiency removal of technetium values from a nuclear waste stream is achieved by addition to the waste stream of a precipitant contributing tetraphenylphosphonium cation, such that a substantial portion of the technetium values are precipitated as an insoluble pertechnetate salt.
Volckaert, Veerle; Vandermeulen, Eva; Duchateau, Luc; Saunders, Jimmy H; Peremans, Kathelijne
2016-04-01
The aim of this study was to assess inter- and intraobserver variability of commonly used semi-quantitative and quantitative parameters in feline thyroid scintigraphy: thyroid to salivary gland ratio (T/S), thyroid to background ratio (T/B) and the percentage technetium pertechnetate uptake for the thyroid glands (%TcUT). These parameters are being used to diagnose thyroid disease and to assess its severity, but may be influenced by operator related factors when processing the images. Additionally, inter- and intraobserver variability of the percentage technetium pertechnetate uptake for the salivary glands was determined (%TcUSG). The study included technetium pertechnetate scans of 100 hyperthyroid cats. Variability within and between three observers was determined using a random effects model and variance components were estimated by the restricted maximum likelihood procedure. The %TcU for the thyroid and salivary glands, as well as the T/S ratio, showed little to no difference in inter- and intraobserver variability, whereas this was clearly present for the T/B ratio. Overall, the T/S ratio and %TcUSG showed a good repeatability and reproducibility with low inter- and intraobserver variabilities. Inter- and intraobserver variability was higher for the %TcUT, however variations were still considered to be acceptable. On the contrary, inter- and intraobserver variability was clearly larger for the T/B ratio. These findings suggest the preferential use of the T/S ratio or %TcU, especially in facilities with a less experienced staff. Crown Copyright © 2016. Published by Elsevier Ltd. All rights reserved.
Deutsch, E; Elder, R C; Lange, B A; Vaal, M J; Lay, D G
1976-01-01
Reduction of pertechnetate by tin(II) in the presence of dimethylglyoxime is shown, by single crystal x-ray analysis, to yield a technetium-tin-dimethylglyoxime complex in which tin and technetium are intimately connected by a triple bridging arrangement. One bridge consists of a single oxygen atom and it is hypothesized that this bridge arises from the inner sphere reduction of technetium by tin(II), the electrons being transferred through a technetium "yl" oxygen which eventually becomes the bridging atom. Two additional bridges arise from two dimethylglyoxime ligands that function as bidentate nitrogen donors towards Tc and monodentate oxygen donors towards Sn. The tin atom can thus be viewed as providing a three-pronged "cap" on one end of the Tc-dimethylglyoxime complex. The additional coordination sites around Tc are occupied by the two nitrogens of a third dimethylglyoxime ligand, making the Tc seven-coordinate. The additional coordination sites around Sn are occupied by three chloride anions, giving the Sn a fac octahedral coordination environment. From indirect evidence the oxidation states of tin and technetium are tentatively assigned to be IV and V, respectively. Since most 99mTc-radiopharmaceuticals are synthesized by the tin(II) reduction of pertechnetate, it is likely that the Sn-O-Tc linkage described in this work is an important feature of the chemistry of these species. This linkage also provides a ready rationale for the close association of tin and technetium observed in many 99mTc-radiopharmaceuticals. PMID:1069984
Intraoperative gamma probe guidance with 99mTc-pertechnetate in the completion thyroidectomy.
Aras, Gülseren; Gültekin, Salih Sinan; Küçük, Nuriye Ozlem; Demirer, Seher; Tuğ, Tuğbay
2009-07-01
Intraoperative gamma probe (GP) guidance with (99m)Tc-pertechnetate in the completion total thyroidectomy after a first thyroidectomy was investigated in this prospective study. The study group comprises of fourteen consecutive patients (14 females, age mean 50.2 +/- 12.0 years, age range 29-73 years). All patients underwent a second thyroidectomy due to inadequate (5/14 patients) and complementary (9/14 patients) interventions. Serum-free three iodothyronine, free thyroxin and thyroid stimulating hormone measurements, a neck ultrasonography (USG) and thyroid scintigraphy (TS) were performed in the preoperative and postoperative period. After a 185 MBq (5 mCi) injection of (99m)Tc-pertechnetate, background (BG), left thyroid lobe (LTL), right thyroid lobe (RTL) and pyramidal tyroid lobe (PTL) regions were counted in time before and after resection of thyroid remnants by intraoperative GP. All resection materials were evaluated by histopathologic examination. Preoperative TSH was less than 30 mIU/mL (mean 21 +/- 7) in all patients. Functioning thyroid remnants were shown in 13/14 patients on the preoperative TS and USG, which were diagnosed by USG in one but by TS in other one. We calculated that percentage median (minimum-maximum) values were 220.90% (56.00-411.11%) in LTL, 80.43% (11.54-471.05%) in RTL and 66.60% (-3.33 to 158.33%) in PTL for counts before resection, on the other hand, 15.96% (-20.55 to 47.62%) in LTL, 17.59% (-15.07 to 38.46%) in RTL and 17.59% (-1.96 to 57.14%) in PTL regions for counts after resection. There were statistically significant differences between these values belonging to before and after resection for LTL (p = 0.001), RTL (p = 0.001) and PTL (p = 0.008). Bilateral small foci in a patient and unilateral focus in other patient were observed in postoperative TS. Unilateral focus was detected on the RTL by GP, but not bilateral foci. Postoperative TSH levels increased to 30 mIU/mL (mean 69 +/- 26) at least. There was a statistically significant difference between preoperative and postoperative TSH values (p < 0.001). Histopathologic confirmation revealed that all removed materials were the thyroid tissues. Gamma probe guidance with (99m)Tc-pertechnetate seemed to be a good option and easy available method in patients undergoing the completion total thyroidectomy.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tratnyek, Paul G.; Tebo, Bradley M.; Fan, Dimin
One way to minimize the mobility of the Tc VII oxyanion pertechnetate (TcO 4 -) is to effect reduction under sulfidogenic conditions (generated abiotically by Fe 0 or biotically) to form TcS x, which is significantly slower to oxidize than Tc IVO 2. In sediment systems, TcS x and other precipitates may oxidize more slowly due to oxygen diffusion limitations to these low permeability precipitate zones. In addition, the TcO 4 - reduction rate may be more rapid in the presence of sediment because of additional reductive surface phases. This project aims to provide a fundamental understanding of the feasibilitymore » of immobilization of TcO 4 - as TcS x in the vadose zone or groundwater by application nano zero-valent iron (nZVI), and sulfide or sulfate. Biotic batch experiments have used the sulfate-reducing bacterium (SRB) Desulfotomaculum reducens. The iron sulfide mineral mackinawite was generated under these conditions, while vivianite was formed in nZVI only controls. The sulfide/bacteria-containing system consistently reduced aqueous pertechnetate rapidly (> 95% in the first hour), a rate similar to that for the sulfide-free, nZVI only system. Reduced Tc (aged for 3 months) generated in both SRB/nZVI systems was highly resistant to reoxidation. In reduced samples, Tc was found associated with solid phases containing Fe and S (D. reducens/nZVI) or Fe (nZVI only). Experiments using D. reducens without nZVI provided some additional insights. Firstly, stationary phase cultures were able to slowly reduce pertechnetate. Secondly, addition of pertechnetate at the beginning of cell growth (lag phase) resulted in a faster rate of Tc reduction, possibly indicating a direct (e.g. enzymatic) role for D. reducens in Tc reduction. Abiotic batch experiments were conducted with Na 2S as the sulfide source. Pertechnetate reduction was rapid in the presence of sulfide and nZVI, although the rate was suppressed at the higher S/Fe ratios tested. This suppression appeared to be due to the formation of Tc-containing colloids. As with the biotic experiments, pertechnetate reduced under sulfidic conditions was highly resistant to reoxidation. The microscopic morphology of abiotically-transformed nZVI particles varied significantly with those in the biotic experiment, although mackinawite was formed in both systems (as indicated by μXRD and Mössbauer spectroscopy). Preliminary XAS analysis pointed to a mixture of Tc-O and Tc-S binding in the abiotic sulfide/nZVI system, while the major reduced solids under non-sulfidic conditions were TcO 2•nH 2O. The presence of sediment and advective flow to the TcO 4 -/nZVI/sulfide system results in additional processes occurring. Although the natural Hanford sediment used has sufficient available ferrous iron to slowly reduce TcO 4 -, under anaerobic conditions, that rate is orders of magnitude slower than reduction by nZVI/sulfide. Batch and 1-D column experiments showed that the TcO 4 - reduction rate increased with the sediment surface area (with the same nZVI mass). As in batch systems, column studies showed that the presence of sulfide with TcO 4 - at low (2-5 mM) concentrations increased the TcO 4 - reduction rate and high (10-30 mM) sulfide decreased the rate. This change is attributed to the formation of sulfide precipitates on the nZVI and sediment surfaces. Injection of low and high sulfide (i.e. pretreatment) prior to TcO 4 -/sulfide injection also greatly decreased the TcO 4 - reduction rate, likely decreasing the generation of ferrous iron from the nZVI. Although the high sulfide systems have slower Tc reduction rates, 190 times more Tc mass precipitated than in the low sulfide systems and the highest fraction of Tc mass remained immobilized.« less
Congenital hypothyroidism: diagnostic scintigraphic evaluation of an organification defect
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cone, L.; Oates, E.; Vazquez, R.
1988-06-01
Quantitative Tc-99m pertechnetate thyroid imaging was performed on a hypothyroid neonate. The image revealed markedly increased trapping in an enlarged, bilobed, eutopic gland. A perchlorate washout test using quantitative imaging with I-123 confirmed an organification problem.
Establishment of an Effective Radioiodide Thyroid Ablation Protocol in Mice.
Schmohl, Kathrin A; Müller, Andrea M; Schwenk, Nathalie; Knoop, Kerstin; Rijntjes, Eddy; Köhrle, Josef; Heuer, Heike; Bartenstein, Peter; Göke, Burkhard; Nelson, Peter J; Spitzweg, Christine
2015-09-01
Due to the high variance in available protocols on iodide-131 ((131)I) ablation in rodents, we set out to establish an effective method to generate a thyroid-ablated mouse model that allows the application of the sodium iodide symporter (NIS) as a reporter gene without interference with thyroidal NIS. We tested a range of (131)I doses with and without prestimulation of thyroidal radioiodide uptake by a low-iodine diet and thyroid-stimulating hormone (TSH) application. Efficacy of induction of hypothyroidism was tested by measurement of serum T4 concentrations, pituitary TSHβ and liver deiodinase type 1 (DIO1) mRNA expression, body weight analysis, and (99m)Tc-pertechnetate scintigraphy. While 200 µCi (7.4 MBq) (131)I alone was not sufficient to abolish thyroidal T4 production, 500 µCi (18.5 MBq) (131)I combined with 1 week of a low-iodine diet decreased serum concentrations below the detection limit. However, the high (131)I dose resulted in severe side effects. A combination of 1 week of a low-iodine diet followed by injection of bovine TSH before the application of 150 µCi (5.5 MBq) (131)I decreased serum T4 concentrations below the detection limit and significantly increased pituitary TSHβ concentrations. The systemic effects of induced hypothyroidism were shown by growth arrest and a decrease in liver DIO1 expression below the detection limit. (99m)Tc-pertechnetate scintigraphy revealed absence of thyroidal (99m)Tc-pertechnetate uptake in ablated mice. In summary, we report a revised protocol for radioiodide ablation of the thyroid gland in the mouse to generate an in vivo model that allows the study of thyroid hormone action using NIS as a reporter gene.
Establishment of an Effective Radioiodide Thyroid Ablation Protocol in Mice
Schmohl, Kathrin A.; Müller, Andrea M.; Schwenk, Nathalie; Knoop, Kerstin; Rijntjes, Eddy; Köhrle, Josef; Heuer, Heike; Bartenstein, Peter; Göke, Burkhard; Nelson, Peter J.; Spitzweg, Christine
2015-01-01
Due to the high variance in available protocols on iodide-131 (131I) ablation in rodents, we set out to establish an effective method to generate a thyroid-ablated mouse model that allows the application of the sodium iodide symporter (NIS) as a reporter gene without interference with thyroidal NIS. We tested a range of 131I doses with and without prestimulation of thyroidal radioiodide uptake by a low-iodine diet and thyroid-stimulating hormone (TSH) application. Efficacy of induction of hypothyroidism was tested by measurement of serum T4 concentrations, pituitary TSHβ and liver deiodinase type 1 (DIO1) mRNA expression, body weight analysis, and 99mTc-pertechnetate scintigraphy. While 200 µCi (7.4 MBq) 131I alone was not sufficient to abolish thyroidal T4 production, 500 µCi (18.5 MBq) 131I combined with 1 week of a low-iodine diet decreased serum concentrations below the detection limit. However, the high 131I dose resulted in severe side effects. A combination of 1 week of a low-iodine diet followed by injection of bovine TSH before the application of 150 µCi (5.5 MBq) 131I decreased serum T4 concentrations below the detection limit and significantly increased pituitary TSHβ concentrations. The systemic effects of induced hypothyroidism were shown by growth arrest and a decrease in liver DIO1 expression below the detection limit. 99mTc-pertechnetate scintigraphy revealed absence of thyroidal 99mTc-pertechnetate uptake in ablated mice. In summary, we report a revised protocol for radioiodide ablation of the thyroid gland in the mouse to generate an in vivo model that allows the study of thyroid hormone action using NIS as a reporter gene. PMID:26601076
The continuing importance of thyroid scintigraphy in the era of high-resolution ultrasound.
Meller, J; Becker, W
2002-08-01
At the molecular level, the uptake of radioiodine and pertechnetate is proportional to the expression of the thyroidal sodium/iodine symporter (NIS). Qualitative and quantitative scintigraphic evaluation of the thyroid is performed with a gamma camera fitted with an on-line computer system and enables determination of the iodine uptake or the technetium uptake (TCTU) as an iodine clearance equivalent. Despite new molecular genetic insights into congenital hypothyroidism, the iodine-123 or pertechnetate scan remains the most accurate test for the detection of ectopic thyroid tissue. Following the identification of specific mutations of the genes coding for the NIS, thyroid peroxidase and pendrin, the discharge test has lost its role in establishing the diagnosis of inherited dyshormonogenesis, but it is still of value in the assessment of defect severity. In PDS mutations the test can be used to establish the diagnosis of syndromic disease. Quantitative pertechnetate scintigraphy is the most sensitive and specific technique for the diagnosis and quantification of thyroid autonomy. The method has proved to be valuable in risk stratification of spontaneous or iodine-induced hyperthyroidism, in the estimation of the target volume prior to radioiodine therapy and in the evaluation of therapeutic success after definitive treatment. In iodine deficiency areas the thyroid scan remains indispensable for the functional characterisation of a thyroid nodule and is still a first-line diagnostic procedure in cases of suspected thyroid malignancy. This is especially of importance in patients with Graves' disease, among whom a relatively high prevalence of cancer has been found in cold thyroid nodules. While determination of the TCTU is without any value in the differentiation between autoimmune thyroiditis and Graves' disease in most cases, it is of substantial importance in the differentiation between hyperthyroid autoimmune thyroiditis and Graves' disease.
Precipitation process for the removal of technetium values from nuclear waste solutions
Walker, D.D.; Ebra, M.A.
1985-11-21
High efficiency removal of techetium values from a nuclear waste stream is achieved by addition to the waste stream of a precipitant contributing tetraphenylphosphonium cation, such that a substantial portion of the technetium values are precipitated as an insoluble pertechnetate salt.
Process for preparing radiopharmaceuticals
Barak, Morton; Winchell, Harry S.
1977-01-04
A process for the preparation of technetium-99m labeled pharmaceuticals is disclosed. The process comprises initially isolating technetium-99m pertechnetate by adsorption upon an adsorbent packing in a chromatographic column. The technetium-99m is then eluted from the packing with a biological compound to form a radiopharmaceutical.
LABORATORY REPORT ON THE REMOVAL OF PERTECHNETATE FROM TANK 241-AN-105 SIMULANT USING PUROLITE A530E
DOE Office of Scientific and Technical Information (OSTI.GOV)
DUNCAN JB; HAGERTY KJ, MOORE WP; JOHNSON JM
2012-04-17
This report documents the laboratory testing and analyses as directed under the test plan, LAB-PLN-11-00010, Evaluation of Technetium Ion Exchange Material against Hanford Double Shell Tank Supernate Simulate with Pertechnetate. Technetium (Tc-99) is a major fission product from nuclear reactors, and because it has few applications outside of scientific research, most of the technetium will ultimately be disposed of as nuclear waste. The radioactive decay of Tc-99 to ruthenium 99 (Ru-99) produces a low energy {beta}{sup -} particle (0.1 MeV max). However, due to its fairly long half-life (t{sub 1/2} = 2.13E05 years), Tc-99 is a major source of radiationmore » in low-level waste (UCRL-JRNL-212334, Current Status of the Thermodynamic Data for Technetium and its Compounds and Aqueous Species). Technetium forms the soluble oxy anion, TcO{sub 4}{sup -} under aerobic conditions. This anion is very mobile in groundwater and poses a health risk (ANL, Radiological and Chemical Fact Sheets to Support Health Risk Analyses for Contaminated Areas). It has been demonstrated that Purolite{reg_sign} A530E is highly effective in removing TcO{sub 4}{sup -} from a water matrix (RPP-RPT-23199, The Removal of Technetium-99 from the Effluent Treatment Facility Basin 44 Waste Using Purolite A-530E, Reillex HPQ, and Sybron IONAC SR-7 Ion Exchange Resins). Purolite{reg_sign} A530E is the commercial product of the Oak Ridge National Laboratory's Biquat{trademark} resin (Gu, B. et. ai, Development of Novel Bifunctional Anion-Exchange Resins with Improved Selectivity for Pertechnetate Sorption from Contaminated Groundwater). Further work has demonstrated that technetium-loaded A530E achieves a leachability index in Cast Stone of 12.5 (ANSI/ASN-16.1-2003, Measurement of the Leachability of Solidified Low-Level Radioactive Wastes by a Short-term Test Procedure) as reported in RPP-RPT-39195, Assessment of Technetium Leachability in Cement-Stabilized Basin 43 Groundwater Brine. This effort falls under the technetium management initiative and will provide data for those who will make decisions on the handling and disposition of technetium. To that end, the objective of this effort was to challenge Purolite{reg_sign} A530E against a double-shell tank (DST) simulant (tank 241-AN-105 or AN-105) spiked with pertechnetate (TcO{sub 4}{sup -}) to determine breakthrough of the lead column.« less
Corrosion Behavior of Nuclear Waste Storage Canister Materials
NASA Astrophysics Data System (ADS)
Grant, John
The nature of interaction of mild steel nuclear waste storage containers with technetium ions is not fully known. Technetium is formed during nuclear processing and some of this technetium has leaked at the Hanford nuclear waste storage site in Washington State. It is often found as highly oxidized pertechnetate (TeO4-) anions at these storage sites which also happen to be highly alkaline and contain a significant amount of nitrate. Theoretically, pertechnetate anions can act as electron acceptors and interact with the mild steel containers and accelerate the oxidation (corrosion) of steel. It is of interest to identify if pertechnetate anions pose a corrosion hazard to the mild steel nuclear waste storage tanks, under the conditions of the storage sites, as that can accelerate the degradation of the tanks and lead to further contamination. In this thesis, the interaction of two relevant container materials, namely, steel alloys A285 and A537 with a technetium surrogate, rhenium was studied. Perrhenate was used as an analog for pertechnetate. As all isotopes of technetium are radioactive, rhenium was chosen as the experimental surrogate due to its chemical similarity to technetium. Electrochemical behavior was evaluated using potentiodynamic polarization tests, and the surface morphology was studied using optical microscopy and scanning electron microscopy. Potentiodynamic polarization tests were conducted in 1.0M NaNO3 + 0.1M NaOH and 1.0M NaNO3 + 0.1M NaOH + 0.02M NaReO4. Tests were performed at three different temperatures, namely, (i) room temperature, (ii) 50°C and (iii) 80°C to study the effect of higher temperatures found in the storage sites. Corrosion current, corrosion potential, anodic and cathodic Tafel slopes, polarization resistance and corrosion rates were obtained from electrochemical testing and evaluated. Increasing temperatures was found to lead to increasing corrosion rates for all samples. The data also revealed increased corrosion from sodium perrhenate on the mild steel A285 samples. The perrhenate anion (ReO4-) formed a redox couple with iron in the mild steel and accelerated metal dissolution that increased with temperature. Pitting and uniform corrosion was observed in the A285 and A537 mild steel samples. The A537 mild steel, however, displayed lower corrosion rates in the presence of perrhenate compared in the absence of perrhenate. A hypothesis has been proposed to explain the differences between the two alloys.
2010-08-01
maximum contaminant level mg-N/kg milligrams of nitrogen per kilogram N2 nitrogen NA not applicable ND non-detect NDMA n-nitrosodimethylamine...Pertechnetate N-Nitrosodimethylamine ( NDMA ) Chlorinated VOCs such as trichloroethene (TCE) Highly energetic compounds including nitro
Effect of Dietary Intake of Stable Iodine on Dose-per-unit-intake Factors for 99Tc
DOE Office of Scientific and Technical Information (OSTI.GOV)
Strom, Daniel J.
It is well-known that the human thyroid concentrates iodine more than 100 times the concentration in plasma. Also well-known is the fact that large amounts of stable iodine in the diet can limit thyroid uptake of total iodine; this is the basis for administering potassium iodide following a release of radioiodine from a nuclear reactor accident or nuclear weapon detonation. Many researchers have shown enhanced concentrations of both organic and inorganic iodine in saliva and breast milk. Technetium-99 is a long-lived (231,000 year half-life) radionuclide of concern in the management of high-level radioactive waste. There is no doubt that 99Tc,more » if it is in groundwater, will be found in the chemical form of pertechnetate, 99TcO4?. Pertechnetate is a large anion, almost identical in size to iodide, I?. The nuclear medicine literature shows that pertechnetate concentrates in the thyroid, salivary glands, and lactating breast in addition to the stomach, liver, and alimentary tract as currently recognized by the International Commission on Radiological Protection (ICRP). The fact that large intakes of stable iodine (127I) in the diet limit uptake of iodine by the thyroid leads one to generalize that stable iodine in the diet may also limit thyroid uptake of pertechnetate. While there is at least one report that iodine in the diet blocks uptake of 99mTcO4? by the thyroid and salivary glands (which have the same Na/I symporter, the biochemical concentration mechanism), the level of protective effect seen for blocking radioactive iodine is not expected for 99TcO4? because pertechnetate does not become organically bound in the thyroid and thus is not retained for months the way iodide is. While it does account for Tc concentration in the thyroid, the existing ICRP biokinetic model for technetium does not take enhanced concentrations in salivary gland and breast tissue into account. From the survey of the nuclear medicine literature, it is not possible to compute the effect of stable iodine in the diet on the dose per unit intake factors for 99Tc without developing an improved biokinetic model for technetium. Specific experiments should be designed to quantitatively evaluate 99TcO4? metabolism, excretion, and secretion, as well as to evaluate its chemical toxicity It is recommended that the ICRP reexamine its biokinetics models for Tc based on nuclear medicine data that have accumulated over the years. In particular, the ICRP ignores the lactation pathway, the enhanced concentration of Tc in breast and breast milk, and enhanced concentration of Tc (and I) in the salivary glands as well as in the thyroid. The ICRP should also explicitly incorporate the effect of stable iodine in the diet into both its models for iodine and technetium. The effect of concentration of Tc in breast milk needs further study for dosimetric implications to nursing infants whose mothers may ingest 99TcO4? from groundwater sources. The ICRP should also investigate the possibility of enhanced concentration of both I and Tc in the non-lactating female breast. To do these re-evaluations of biokinetic models, new experiments designed specifically to evaluate these questions concerning the biokinetics of Tc and I are needed.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Holmes, K.A.; Ponto, J.A.
1981-09-01
Increased thyroid activity was incidentally observed during an in vivo labeled Tc-99m blood pool scan and subsequent evaluation resulted in a diagnosis of hypothyroidism. Alternate explanations of abnormal thyroid uptake on in vivo labeled blood pool scans were considered and are discussed briefly.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tavormina, A.; Mousavi, A.; Gordon, D.H.
A case of vascular ectasia of the cecum is presented. The isotopic pattern did not differ from that of Meckel's diverticulum. The authors suggest that studies with /sup 99m/Tc may be helpful in screening for areas of pathology in cases of lower gastrointestinal bleeding.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hamm, L.; Smith, F.; Aleman, S.
2013-05-16
This report documents the development and application of computer models to describe the sorption of pertechnetate [TcO₄⁻], and its surrogate perrhenate [ReO₄⁻], on SuperLig® 639 resin. Two models have been developed: 1) A thermodynamic isotherm model, based on experimental data, that predicts [TcO₄⁻] and [ReO₄⁻] sorption as a function of solution composition and temperature and 2) A column model that uses the isotherm calculated by the first model to simulate the performance of a full-scale sorption process. The isotherm model provides a synthesis of experimental data collected from many different sources to give a best estimate prediction of the behaviormore » of the pertechnetate-SuperLig® 639 system and an estimate of the uncertainty in this prediction. The column model provides a prediction of the expected performance of the plant process by determining the volume of waste solution that can be processed based on process design parameters such as column size, flow rate and resin physical properties.« less
Akchata, Suman; Lavanya, K; Shivanand, Bhushan
2017-01-01
Decontamination of various working surfaces with sodium pertechnetate minor spillage is essential for maintaining good radiation safety practices as well as for regulatory compliance. To observe the influences of decontaminating agents and swipe materials on different type of surfaces used in nuclear medicine laboratory work area wet spilled with 99m-technetium (99mTc) sodium pertechnetate. Lab-simulated working surface materials. Experimental study design. Direct decontamination method on dust-free lab simulated new working surfaces [stainless steel, polyvinyl chloride (PVC), Perspex, resin] using four decontaminating agents [tap water, soap water (SW), Radiacwash, and spirit] with four different swipe material [cotton, tissue paper (TP), Whatman paper (WP), adsorbent sheet (AS)] was taken 10 samples (n = 10) for each group. Parametric test two-way analysis of variance is used with significance level of 0.005, was used to evaluate statistical differences between different group of decontaminating agent and swipe material, and the results are expressed in mean ± SD. Decontamination factor is calculated after five cleaning for each group. A total of 160 samples result calculated using four decontaminating agent (tap water, SW, Radiacwash, and spirit), four swipe material (cotton, TP, WP, and AS) for commonly used surface (stainless steel, PVC, Perspex, resin) using direct method by 10 samples (n = 10) for each group. Tap water is the best decontaminating agent compared with SW, Radiac wash and spirit for the laboratory simulated stainless steel, PVC, and Perspex surface material, whereas in case of resin surface material, SW decontaminating agent is showing better effectiveness. Cotton is the best swipe material compared to WP-1, AS and TP for the stainless steel, PVC, Perspex, and resin laboratory simulated surface materials. Perspex and stainless steel are the most suitable and recommended laboratory surface material compared to PVC and resin in nuclear medicine. Radiacwash may show better result for 99mTc labelled product and other radionuclide contamination on the laboratory working surface area.
Akchata, Suman; Lavanya, K; Shivanand, Bhushan
2017-01-01
Context: Decontamination of various working surfaces with sodium pertechnetate minor spillage is essential for maintaining good radiation safety practices as well as for regulatory compliance. Aim: To observe the influences of decontaminating agents and swipe materials on different type of surfaces used in nuclear medicine laboratory work area wet spilled with 99m-technetium (99mTc) sodium pertechnetate. Settings and Design: Lab-simulated working surface materials. Experimental study design. Materials and Methods: Direct decontamination method on dust-free lab simulated new working surfaces [stainless steel, polyvinyl chloride (PVC), Perspex, resin] using four decontaminating agents [tap water, soap water (SW), Radiacwash, and spirit] with four different swipe material [cotton, tissue paper (TP), Whatman paper (WP), adsorbent sheet (AS)] was taken 10 samples (n = 10) for each group. Statistical Analysis: Parametric test two-way analysis of variance is used with significance level of 0.005, was used to evaluate statistical differences between different group of decontaminating agent and swipe material, and the results are expressed in mean ± SD. Results: Decontamination factor is calculated after five cleaning for each group. A total of 160 samples result calculated using four decontaminating agent (tap water, SW, Radiacwash, and spirit), four swipe material (cotton, TP, WP, and AS) for commonly used surface (stainless steel, PVC, Perspex, resin) using direct method by 10 samples (n = 10) for each group. Conclusions: Tap water is the best decontaminating agent compared with SW, Radiac wash and spirit for the laboratory simulated stainless steel, PVC, and Perspex surface material, whereas in case of resin surface material, SW decontaminating agent is showing better effectiveness. Cotton is the best swipe material compared to WP-1, AS and TP for the stainless steel, PVC, Perspex, and resin laboratory simulated surface materials. Perspex and stainless steel are the most suitable and recommended laboratory surface material compared to PVC and resin in nuclear medicine. Radiacwash may show better result for 99mTc labelled product and other radionuclide contamination on the laboratory working surface area. PMID:28680198
Góes, Vanessa Coelho; Neves, Renata Heisler; Arnóbio, Adriano; Bernardo-Filho, Mario; Machado-Silva, José Roberto
2016-09-01
Technetium-99m ((99m)Tc) is a radionuclide commonly used in nuclear medicine to obtain (99m)Tc-radiopharmaceuticals, which can be used to evaluate either physiological processes or changes related to diseases. It is also used in some experimental studies. Streptozotocin (STZ) administration to rodents causes lesions in very early stages and induces severe and permanent diabetes. Most morbidity of schistosomiasis mansoni is attributed to a granulomatous inflammatory response and associated liver fibrosis. This study was designed to investigate whether STZ administration and schistosomiasis modify the biodistribution of the radiopharmaceutical sodium (99m)Tc-pertechnetate. Adult female mice were infected by exposure to 100Schistosoma mansoni cercariae (BH strain, Belo Horizonte, Brazil) and euthanized after nine weeks. STZ was administered by a single intraperitoneal injection of 100mg/kg body weight, 3 or 15days before euthanasia. Each animal received 100μl of sodium (Na) (99m)Tc-pertechnetate ((99m)TcO4(-)) (740kBq). The animals were divided into four groups: A, uninfected; B, infected; C, uninfected + STZ; and D, infected + STZ. Blood, brain, thyroid, heart, lungs, liver, spleen, pancreas and kidneys were removed. The radioactivity was counted and the percentage of the injected dose of Na(99m)TcO4 per gram of the organ (% ID/g) was determined. Three days after the STZ injection, there was a decrease of Na(99m)TcO4 uptake by the liver, lungs, pancreas and kidneys (p<0.05) in group D when compared with group A. After 15days, the decrease of Na(99m)TcO4 uptake occurred also in the brain, thyroid, heart, spleen and blood (p<0.05) in group D. We demonstrated modifications on the biodistribution of Na(99m)TcO4 due to STZ administration and schistosomiasis, possibly due to physiological alterations in some organs. The biodistribution of radiopharmaceutical Na(99m)TcO4 should be carefully evaluated in subjects with diabetes and/or schistosomiasis infection. Copyright © 2016 Elsevier Inc. All rights reserved.
Darr, Andreas M; Opfermann, Thomas; Niksch, Tobias; Driesch, Dominik; Marlowe, Robert J; Freesmeyer, Martin
2013-10-01
The standard thyroid functional imaging method, 99mTc-pertechnetate (99mTc-PT) planar scintigraphy, has technical drawbacks decreasing its sensitivity in detecting nodules or anatomical pathology. 124I-PET, lacking these disadvantages and allowing simultaneous CT, may have greater sensitivity for these purposes. We performed a blinded pilot comparison of 124I-PET(/CT) versus 99mTc-PT planar scintigraphy or its cross-sectional enhancement, 99mTc-PT single-photon emission CT (SPECT), in characterizing the thyroid gland with benign disease. Twenty-one consecutive adults with goiter underwent low-activity (1 MBq/0.027 mCi) 124I-PET/low-dose (30 mAs) CT, 99mTc-PT planar scintigraphy, and 99mTc-PT-SPECT. Endpoints included the numbers of “hot spots” with/without central photopenia and “cold spots” detected, the proportion of these lesions with morphological correlates, the mean volume and diameter of visualized nodules, and the number of cases of lobus pyramidalis or retrosternal thyroid tissue identified. 124I-PET detected significantly more “hot spots” with/without central photopenia (P < 0.001), significantly more nodules (P < 0.001), and more “cold spots” than did 99mTc-PT planar scintigraphy or 99mTc-PT-SPECT, including all lesions seen on the 99mTc-PT modalities. Ultrasonographic correlates were found for all nodules visualized on all 3 modalities and 92.5% of nodules seen only on 124I-PET. Nodules discernible only on 124I-PET had significantly smaller mean volume or diameter (P < 0.001) than did those visualized on 99mTc-PT planar scintigraphy or 99mTc-PT-SPECT. 124I-PET(/CT) identified significantly more patients with a lobus pyramidalis (P < 0.001) or retrosternal thyroid tissue (P < 0.05). 124I-PET(/CT) may provide superior imaging of benign thyroid disease compared to planar or cross-sectional 99mTc-PT scintigraphy.
The uterine blush. A potential false-positive in Meckel's scan interpretation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fink-Bennett, D.
To determine the presence, prevalence, and clinical importance of /sup 99m/Tc pertechnetate uterine uptake, this retrospective analysis of 71 Meckel's scans was undertaken. Specifically, each study was evaluated for the presence of a focal accumulation of radiotracer cephalad to the bladder. Patients received an intravenous dose of 150 microCi/kg of /sup 99m/Tc pertechnetate. Each study consisted of 15 one minute anterior serial gamma camera images, and a 15, 30, and 60 minute anterior, right lateral and posterior scintiscan. Menstrual histories were obtained from all patients except two. No males (33/33), nor premenstrual (13/13), menopausal (4/4) or posthysterectomy (2/2) patients revealedmore » a uterine blush. Eleven of 15 patients (73%) with regular menses demonstrated a uterine blush. They were in the menstrual or secretory phases of their cycle. Four demonstrated no uterine uptake, had regular periods, but were in the proliferative phase of their cycle. Two with irregular periods, and one with no recorded menstrual history, manifested the blush. Radiotracer should be expected in the uterus during the menstrual and secretory phases of the menstrual cycle. It is a manifestation of a normal physiologic phenomenon, and must be recognized to prevent false-positive Meckel's scan interpretations.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ding, Mei; Tang, Ming; Rim, Jung Ho
Alternative treatment and disposition options may exist for technetium-99 (99Tc) in secondary liquid waste from the Hanford Direct-Feed Low-Activity Waste (DFLAW) process. One approach includes development of an alternate glass waste form that is suitable for on-site disposition of technetium, including salts and other species recovered by ion exchange or precipitation from the EMF evaporator concentrate. By recovering the Tc content from the stream, and not recycling the treated concentrate, the DFLAW process can potentially be operated in a more efficient manner that lowers the cost to the Department of Energy. This report provides a survey of candidate glass formulationsmore » and glass-making processes that can potentially incorporate technetium at temperatures <700 °C to avoid volatilization. Three candidate technetium feed streams are considered: (1) dilute sodium pertechnetate loaded on a non-elutable ion exchange resin; (2) dilute sodium-bearing aqueous eluent from ion exchange recovery of pertechnetate, or (3) technetium(IV) oxide precipitate containing Sn and Cr solids in an aqueous slurry. From the technical literature, promising candidate glasses are identified based on their processing temperatures and chemical durability data. The suitability and technical risk of three low-temperature glass processing routes (vitrification, encapsulation by sintering into a glass composite material, and sol-gel chemical condensation) for the three waste streams was assessed, based on available low-temperature glass data. For a subset of candidate glasses, their long-term thermodynamic behavior with exposure to water and oxygen was modeled using Geochemist’s Workbench, with and without addition of reducing stannous ion. For further evaluation and development, encapsulation of precipitated TcO2/Sn/Cr in a glass composite material based on lead-free sealing glasses is recommended as a high priority. Vitrification of pertechnetate in aqueous anion exchange eluent solution using a high lead content borate glass, or other low melting glass is also recommended for further evaluation and development. Additional laboratory studies of phase behavior and chemical durability of low-temperature glasses is also recommended to provide risk mitigation if one of the primary development paths proves infeasible. This report is a deliverable for the task “Candidate Low-T Glass Waste Forms for EMF Bottoms On-Site Disposition Alternative Option.”« less
Ion Exchange Column Tests Supporting Technetium Removal Resin Maturation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nash, C.; McCabe, D.; Hamm, L.
2013-12-20
The primary treatment of the tank waste at the DOE Hanford site will be done in the Waste Treatment and Immobilization Plant, currently under construction. The baseline plan for this facility is to treat the waste, splitting it into High Level Waste (HLW) and Low Activity Waste (LAW). Both waste streams are then separately vitrified as glass and sealed in canisters. The LAW glass will be disposed on site. There are currently no plans to treat the waste to remove technetium, so its disposition path is the LAW glass. Due to the soluble properties of pertechnetate and long half-life ofmore » 99Tc, effective management of 99Tc is important. Options are being explored to immobilize the supplemental LAW portion of the tank waste, as well as to examine the volatility of 99Tc during the vitrification process. Removal of 99Tc, followed by off-site disposal has potential to reduce treatment and disposal costs. A conceptual flow sheets for supplemental LAW treatment and disposal that could benefit from technetium removal will specifically examine removing 99Tc from the LAW feed stream to supplemental immobilization. SuperLig® 639 is an elutable ion exchange resin. In the tank waste, 99Tc is predominantly found in the tank supernate as pertechnetate (TcO 4 -). Perrhenate (ReO 4 -) has been shown to be a good non-radioactive surrogate for pertechnetate in laboratory testing for this ion exchange resin. This report contains results of experimental ion exchange distribution coefficient and column resin maturation kinetics testing using the resin SuperLig® 639a to selectively remove perrhenate from simulated LAW. This revision includes results from testing to determine effective resin operating temperature range. Loading tests were performed at 45°C, and the computer modeling was updated to include the temperature effects. Equilibrium contact testing indicated that this batch of SuperLig® 639 resin has good performance, with an average perrhenate distribution coefficient of 291 mL/g at a 100:1 phase ratio. This slightly exceeds the computer-modeled equilibrium distribution. The modeling agreed well with the experimental data for perrhenate removal with minor adjustments. Predicted breakthrough performance was on average within about 20% of measured values.« less
Sorption of99mTc radiopharmaceutical compounds by soils
Jurisson, S.; Gawenis, J.; Landa, E.R.
2004-01-01
Study of the sorption of 99mTc radiopharmaceutical compounds by soils has assessed the fate of these compounds in the event of a surface spill and examined the potential of these compounds as hydrologic tracers. Sorption from deionized water, filtered Missouri River water, and artificial seawater by five surface soils was investigated. For all water types, the Tc radiopharmaceutical compounds showed greater sorption than the uncomplexed pertechnetate. The most lipophilic complexes showed the highest sorption on soils.
DOE Office of Scientific and Technical Information (OSTI.GOV)
1Harry Reid Center for Environmental Studies, Nuclear Science and Technology Division, University of Nevada, Las Vegas, Las Vegas, NV, 89154-4006; Gong, Cynthia-May S; Poineau, Frederic
2008-02-26
Reductive nitrosylation and complexation of ammonium pertechnetate by acetohydroxamic acid has been achieved in aqueous nitric and perchloric acid solutions. The kinetics of the reaction depend on the relative concentrations of the reaction components and are accelerated at higher temperatures. The reaction does not occur unless conditions are acidic. Analysis of the x-ray absorption fine structure spectroscopic data is consistent with a pseudo-octahedral geometry with the linear Tc-N-O bond typical of technetium nitrosyl compounds, and electron spin resonance spectroscopy is consistent with a the d{sup 5} Tc(II) nitrosyl complex. The nitrosyl source is generally AHA, but may be augmented bymore » products of reaction with nitric acid. The resulting low-valency trans-aquonitrosyl(diacetohydroxamic)-technetium(II) complex (1) is highly soluble in water, extremely hydrophilic, and is not extracted by tri-n-butylphosphate in a dodecane diluent. Its extraction properties are not pH-dependent; titration studies indicate a single species from pH 4.5 down to -0.6 (calculated). This molecule is resistant to oxidation by H{sub 2}O{sub 2}, even at high pH, and can undergo substitution to form other technetium nitrosyl complexes. The formation of 1 may strongly impact the fate of technetium in the nuclear fuel cycle.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Egorov, Oleg; O'Hara, Matthew J.; Grate, Jay W.
An automated fluidic instrument is described that rapidly determines the total 99Tc content of aged nuclear waste samples, where the matrix is chemically and radiologically complex and the existing speciation of the 99Tc is variable. The monitor links microwave-assisted sample preparation with an automated anion exchange column separation and detection using a flow-through solid scintillator detector. The sample preparation steps acidify the sample, decompose organics, and convert all Tc species to the pertechnetate anion. The column-based anion exchange procedure separates the pertechnetate from the complex sample matrix, so that radiometric detection can provide accurate measurement of 99Tc. We developed amore » preprogrammed spike addition procedure to automatically determine matrix-matched calibration. The overall measurement efficiency that is determined simultaneously provides a self-diagnostic parameter for the radiochemical separation and overall instrument function. Continuous, automated operation was demonstrated over the course of 54 h, which resulted in the analysis of 215 samples plus 54 hly spike-addition samples, with consistent overall measurement efficiency for the operation of the monitor. A sample can be processed and measured automatically in just 12.5 min with a detection limit of 23.5 Bq/mL of 99Tc in low activity waste (0.495 mL sample volume), with better than 10% RSD precision at concentrations above the quantification limit. This rapid automated analysis method was developed to support nuclear waste processing operations planned for the Hanford nuclear site.« less
Method of tagging excipients with /sup 99m/Tc
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bardy, A.; Beydon, J.; Gobin, R.
1977-11-08
A method of using /sup 99m/technetium for tagging excipients in medical diagnosis by scintigraphy comprises mixing, in an aqueous solution of alkali-metal pertechnetate, an excipient and a reducing agent in the form of a complex, which complex is such that the association constant of the anion with reduced techetium is less than the association constant of the excipient with reduced technetium, thereby forming a radio-pharmaceutical substance which is a complex between the excipient and /sup 99m/technetium.
Nuclear medicine and esophageal surgery
DOE Office of Scientific and Technical Information (OSTI.GOV)
Taillefer, R.; Beauchamp, G.; Duranceau, A.C.
1986-06-01
The principal radionuclide procedures involved in the evaluation of esophageal disorders that are amenable to surgery are illustrated and briefly described. The role of the radionuclide esophagogram (RE) in the diagnosis and management of achalasia, oculopharyngeal muscular dystrophy and its complications, tracheoesophageal fistulae, pharyngeal and esophageal diverticulae, gastric transposition, and fundoplication is discussed. Detection of columnar-lined esophagus by Tc-99m pertechnetate imaging and of esophageal carcinoma by Ga-67 citrate and Tc-99m glucoheptonate studies also is presented. 37 references.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gong, C.-M.S.; Lukens, W.W.; Poineau, F.
2009-05-18
Reductive nitrosylation and complexation of ammonium pertechnetate by acetohydroxamic acid has been achieved in aqueous nitric and perchloric acid solutions. The kinetics of the reaction depend on the relative concentrations of the reaction components and are accelerated at higher temperatures. The reaction does not occur unless conditions are acidic. Analysis of the X-ray absorption fine structure spectroscopic data is consistent with a pseudo-octahedral geometry and the linear Tc-N-O bond typical of technetium nitrosyl compounds, and electron spin resonance spectroscopy is consistent with a d{sup 5} Tc(II) nitrosyl complex. The nitrosyl source is generally AHA, but it may be augmented bymore » some products of the reaction with nitric acid. The resulting low-valency trans-aquonitrosyl(diacetohydroxamic)-technetium(II) complex ([Tc{sup II}(NO)(AHA){sub 2}H{sub 2}O]{sup +}, 1) is highly soluble in water, extremely hydrophilic, and is not extracted by tri-n-butylphosphate in a dodecane diluent. Its extraction properties are not pH-dependent: potentiometric-spectrophotometric titration studies indicate a single species from pH 4 down to -0.6 (calculated). This molecule is resistant to oxidation by H{sub 2}O{sub 2}, even at high pH, and can undergo substitution to form other technetium nitrosyl complexes. The potential formation of 1 during reprocessing may strongly impact the fate of technetium in the nuclear fuel cycle.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
DI Kaplan; KE Parker; RD Orr
1998-10-14
As part of the Immobilized Low-Activity Waste-Performance Assessment three experiments were conducted to evaluate the effect of the expected near-field chemistry on the sorption of iodide, selenate, and pertechnetate onto a sediment obtained from the Hanford Site. These experiments were performed in fiscal year 1998 at the Pacific Northwest National Laboratory.' During these experiments, attention was directed at the identification of the chemical mechanisms controlling the sorption processes to provide technical defensibility for the selection of the distribution coefficients (IQ to be used in the remainder of the performance assessment. It was found, during the conduct of the experiments, thatmore » selenium and technetium I&s increased as ionic strength increased. The cause for this is most likely to be that the higher ionic strength caused the double layer around the particles to decrease, thereby permitting greater interaction with the mineral surfaces. Further, the pH level had an effect on the sorption of these anions. These are the first-ever experiments conducted with Hanford Site sediment in which the IQ were measured as a function of ionic strength and pH. Overall, the observed trends were consistent with more generalized geochemical principles. One of the most important contributions of these experiments was that they quantified the & changes induced by variations in ionic strength and pH that are expected to exist in the near field.« less
2008-01-01
CT contrast agent, four 6.0mm nylon balls (Small Parts, Inc. Miami Lakes, FL) soaked in aqueous 99mTc-pertechnetate were used as markers and taped ...Inc, Miramar, Fl) were soaked in concentrated aqueous 99mTc and taped to the exterior surface of the breast phantom to act as fiducial markers for...vol. 21, pp. 48-55, 2006. [16] H. Erdogan and J. A. Fessler, "Ordered subsets algorithms for transmission tomography," Phys Med Biol, vol. 44, pp
Bifunctional anion-exchange resins with improved selectivity and exchange kinetics
Alexandratos, Spiro D.; Brown, Gilbert M.; Bonnesen, Peter V.; Moyer, Bruce A.
2000-01-01
Disclosed herein are a class of anion exchange resins containing two different exchange sites with improved selectivity and sorptive capability for chemical species in solution, such as heptavalent technetium (as pertechnetate anion, TcO.sub.4.sup.-). The resins are prepared by first reacting haloalkylated crosslinked copolymer beads with a large tertiary amine in a solvent in which the resin beads can swell, followed by reaction with a second, smaller, tertiary amine to more fully complete the functionalization of the resin. The resins have enhanced selectivity, capacity, and exchange kinetics.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nash, Charles A.; McCabe, Daniel J.
This document presents a literature study of the impact of glycolate on technetium chemistry in the Savannah River Site (SRS) waste system and specifically Saltstone. A predominant portion of the Tc at SRS will be sent to the Saltstone Facility where it will be immobilized. The Tc in the tank waste is in the highly soluble chemical form of pertechnetate ion (TcO 4 -) which is reduced by blast furnace slag (BFS) in Saltstone, rendering it highly insoluble and resistant to leaching.
Role of color Doppler in differentiation of Graves' disease and thyroiditis in thyrotoxicosis
Donkol, Ragab Hani; Nada, Aml Mohamed; Boughattas, Sami
2013-01-01
AIM: To evaluate the role of thyroid blood flow assessment by color-flow Doppler ultrasonography in the differential diagnosis of thyrotoxicosis and compare it to technetium pertechnetate thyroid scanning. METHODS: Twenty-six patients with thyrotoxicosis were included in the study. Clinical history was taken and physical examination and thyroid function tests were performed for all patients. Thyroid autoantibodies were measured. The thyroid glands of all patients were evaluated by gray scale ultrasonography for size, shape and echotexture. Color-flow Doppler ultrasonography of the thyroid tissue was performed and spectral flow analysis of both inferior thyroid arteries was assessed. Technetium99 pertechnetate scanning of the thyroid gland was done for all patients. According to thyroid scintigraphy, the patients were divided into two groups: 18 cases with Graves’ disease and 8 cases with Hashimoto’s thyroiditis. All patients had suppressed thyrotropin. The diagnosis of Graves’ disease and Hashimoto’s thyroiditis was supported by the clinical picture and follow up of patients. RESULTS: Peak systolic velocities of the inferior thyroid arteries were significantly higher in patients with Graves’ disease than in patients with thyroiditis (P = 0.004 in the right inferior thyroid artery and P = 0.001 in left inferior thyroid artery). Color-flow Doppler ultrasonography parameters demonstrated a sensitivity of 88.9% and a specificity of 87.5% in the differential diagnosis of thyrotoxicosis. CONCLUSION: Color Doppler flow of the inferior thyroid artery can be used in the differential diagnosis of thyrotoxicosis, especially when there is a contraindication of thyroid scintigraphy by radioactive material in some patients. PMID:23671754
Schwartz, Frederik; Bergmann, Natasha; Zerahn, Bo; Faber, Jens
2013-04-01
Painless thyroiditis (PT) is a transient kind of thyrotoxicosis, with lack of uptake on a thyroid scintigraphy in a non-tender thyroid gland, elevated anti-TPO antibodies, no fever, no history of increased iodine intake, and a normal sedimentation rate. The prevalence of PT varies hugely in the literature. To establish the incidence rate of PT in Denmark as well as to describe the phenotype of PT in more detail. Tc-99m pertechnetate scintigraphies were performed over a period of 9.75 years on 6022 consecutive patients (2349 had a thyrotoxic episode), and were divided into high or normal (5528), reduced (300) or lack of uptake (194). Patient records were evaluated: 292 with reduced, and 186 with lack of uptake. As a control measure, 230 consecutive thyrotoxic patients were also analyzed. Based on scintigraphies, 12 patients had PT, 10 with lack of uptake and two with reduced, corresponding to an incidence rate of 0.49/100,000 person years. It was predicted, that only one patient among the newly diagnosed consecutive thyrotoxic cohort had PT. This patient was identified. The prevalence of PT among thyrotoxic patients was 0.51% as evaluated by scintigraphy, and 0.43% among the biochemically thyrotoxic patient cohort. Twenty-five percent had more than one thyrotoxic episode, 75% had at least one subsequent hypothyroid episode, and 33% developed permanent hypothyroidism. PT presenting with symptomatic thyrotoxicosis is an extremely rare disease in Denmark. Symptomatic PT presents most often with no uptake on a Tc-99m pertechnetate scintigraphy. Clinical follow-up is essential.
Rapid diagnosis of occult abscesses using sup 99m Tc-labeled monoclonal antibodies
DOE Office of Scientific and Technical Information (OSTI.GOV)
Coons, T.A.; Rhodes, B.A.; Thakur, M.L.
1991-01-01
Acute infections, such as appendicitis and occult infections in AIDS patients, can be diagnosed within two hours by gamma scintigraphy after i.v. administration of {sup 99m}Tc labeled antibodies reactive with human granulocytes. The antibody, murine IgM anti-SSEA-1, is partially reduced using Sn(II) to expose and protect reactive sulfide groups. The antibody is then purified, stannous tartrate and stabilizers are added, and the mixture is lyophilized. To label, sodium pertechnetate is added. After a 15 minute incubation the tracer drug is injected. The rate of accumulation and degree of concentration at the site of infection is presumptively determinative of the severitymore » of the infection. Acceptance criteria and tests for the {sup 99m}Tc labeled antibody product have been established and validated. Greater than 93% of the {sup 99m}Tc is firmly bound to the protein as determined by quantitative HPLC. Radiochemical impurities, colloidal {sup 99m}Tc and free pertechnetate are together less than 4% as determined by thin layer chromatography. The immunoreactive fraction, measured by binding to solid phase antigen, and affinity measured be ELISA, are unchanged by the {sup 99m}Tc-direct labeling process. Two hour blood clearance in rats is within 90% of the value of the {sup 125}I labeled analog. The immunoreactive fraction decreases less than 10% when incubated in human plasma for 24 hours. This method has been compared to other direct labeling methods, and found to give higher radiochemical yields. 5 figs.« less
Brain pertechnetate SPECT in perinatal asphyxia
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sfakianakis, G.; Curless, R.; Goldberg, R.
1984-01-01
Single photon emission computed tomography of the brain was performed in 6 patients with perinatal asphyxis aged 8-26 days. A single-head (LFOV) commercial SPECT system (Picker) was used and data were acquired 2-3 hr after an IV injection of 1-2 mCi Tc-99m-pertechnetate (360/sup 0/ rotation, 60 views, 64 x 64 matrix, 50K cts/view). Reconstruction in three planes was performed using MDS software (Hanning medium resolution filter, with or without attenuation correction using Sorenson's technique). For each clinical study, a ring type phantom source was used to identify the level of reconstruction noise in the tomographic planes. Abnormalities were found inmore » all patients studied, 3 central (moderate intensity), 2 peripheral (1 severe, 1 moderate) and 1 diffuse (mild intensity). Despite use of oral perchlorate (50 mg) in one patient the choroid plexus was visible. Since attenuation correction tended to amplify noise, the clinical studies were interpreted both with and without this correction. All 3 patients with central lesions were found abnormal on early (1-4 mo) neurologic follow-up examination, whereas the others were normal. No correlation was found between SPECT and 24 hr blood levels of CPK, ammonia, base excess, or the Apgar scores. Ct scans were reported abnormal (3 diffuse, 1 peripheral, 1 central and 1 questionable). Planar scintigrams obtained immediately after SPECT were normal (2), questionable (2) and abnormal (2). Follow-up SPECT brain scintigrams in two of the patients showed partial resolution. SPECT of the brain appears promising in perinatal asphyxia but long-term correlation with patient development is necessary.« less
Ghiyas Ud Din; Imran Rafiq Chughtai; Hameed Inayat, Mansoor; Hussain Khan, Iqbal
2009-01-01
Axial mixing, holdup and slip velocity of dispersed phase which are parameters of fundamental importance in the design and operation of liquid-liquid extraction pulsed sieve plate columns have been investigated. Experiments for residence time distribution (RTD) analysis have been carried out for a range of pulsation frequency and amplitude in a liquid-liquid extraction pulsed sieve plate column with water as dispersed and kerosene as continuous phase using radiotracer technique. The column was operated in emulsion region and (99m)Tc in the form of sodium pertechnetate eluted from a (99)Mo/(99m)Tc generator was used to trace the dispersed phase. Axial dispersed plug flow model with open-open boundary condition and two points measurement method was used to simulate the hydrodynamics of dispersed phase. It has been observed that the axial mixing and holdup of dispersed phase increases with increase in pulsation frequency and amplitude until a maximum value is achieved while slip velocity decreases with increase in pulsation frequency and amplitude until it approaches a minimum value. Short lived and low energy radiotracer (99m)Tc in the form of sodium pertechnetate was found to be a good water tracer to study the hydrodynamics of a liquid-liquid extraction pulsed sieve plate column operating with two immiscible liquids, water and kerosene. Axial dispersed plug flow model with open-open boundary condition was found to be a suitable model to describe the hydrodynamics of dispersed phase in the pulsed sieve plate extraction column.
Thyrotoxicosis: a rare presenting symptom of Hurthle cell carcinoma of the thyroid.
Wong, C P; AuYong, T K; Tong, C M
2003-10-01
Hurthle cell carcinoma of the thyroid is a rare type of thyroid neoplasm. The most common clinical presentation is a single palpable thyroid nodule. The neoplasm typically presents as a nonfunctioning or cold nodule on a Tc-99m sodium pertechnetate or radioiodine thyroid scan. We report a case of Hurthle cell carcinoma of the thyroid in a woman presenting with thyrotoxicosis. The Tc-99m thyroid scan was also interesting in that the nodule was a hot or hyperfunctioning area, resulting in a rare scintigraphic finding in a rare tumor. Clinicopathologic aspects and related issues are further discussed.
Transient thyrotoxicosis from thyroiditis induced by sibutramine overdose: a case report.
Kim, S K; Lee, S M; Yoo, S S; Hahm, J R; Jung, J H; Kim, H S; Kim, S; Chung, S I; Jung, T S
2013-08-01
Sibutramine is an antiobesity drug that inhibits the reuptake of serotonin and noradrenalin in the hypothalamus. A 37-year-old Korean man presented to the emergency room for the oral intake of 280 mg of sibutramine. The patient was in thyrotoxic state. The (99m)Technetium-pertechnetate thyroid scan showed irregular uptake of radioisotope and thyroid-stimulating hormone receptor antibody and thyroperoxidase antibody were negative. Thyroid function normalized after that. The patient had transient thyrotoxicosis with thyroiditis. We report a case of thyrotoxicosis accompanied by thyroiditis resulting from the intentional overdose of sibutramine.
Miftari, Ramë; Fejza, Ferki; Bicaj, Xhavit; Nura, Adem; Topciu, Valdete; Bajrami, Ismet
2014-01-01
Purpose: In cases of thyroid toxic autonomous nodule, anterior projection of Tc-99m pertechnetate image shows a hot nodule that occupies most, or the entire thyroid lobe with near-total or total suppression of the contra lateral lobe. In this case is very difficult to distinguish toxic nodule from lobe agenesis. Our interest was to estimate and determinate the rate of radioactivity when the source with high activity can make total suppression of the second source with low activity in same conditions with thyroid scintigraphy procedures. Material and methodology: Thyroid scintigraphy was performed with Technetium 99 meta stable pertechnetate. A parallel high resolution low energy collimator was used as an energy setting of 140 KeV photo peak for T-99m. Images are acquired at 200 Kilo Counts in the anterior projection with the collimator positioned as close as the patient’s extended neck (approximately in distance of 18 cm). The scintigraphy of thyroid gland was performed 15 minutes after intravenous administration of 1.5 mCi Tc-99m pertechnetate. Technetium 99 meta stable radioactive sources with different activity were used for two scintigraphies studies, performed in same thyroid scintigraphy acquisition procedures. In the first study, were compared the standard source with high activity A=11.2 mCi with sources with variable activities B=1.33 mCi; 1.03 mCi; 0.7 mCi; 0.36 mCi; and 0.16mCi) in distance of 1.5cm from each other sources, which is approximately same with distance between two thyroid lobes. In the second study were compared the sources with low activity in proportion 70:1(source A = 1.5 mCi and source B=0.021mCi). As clinical studies we preferred two different patents with different thyroid disorders. There were one patient with thyroid toxic nodule in the right lobe, therefore the second patient was with left thyroid nodule agenesis. Results: During our examination, we accurately determined that two radioactive sources in proportion 70:1 will be displayed as only one source with complete suppression of other source with low radioactivity. Also we found that covering of toxic nodules with lead cover (plaque), can allow visualization of activity in suppressed lobe. Conclusion: Our study concluded that total lobe suppression, in cases of patients with thyroid toxic nodule, will happened for sure, if toxic nodule had accumulated seventy times more radioactivity than normal lobe. Also we concluded that covering of the toxic nodule with lead plaque, may permit the presentation of radioactivity in suppressed nodule. PMID:24825932
DOE Office of Scientific and Technical Information (OSTI.GOV)
DL Blanchard; DE Kurath; BM Rapko
The current BNFL Inc. flow sheet for pretreating Hanford High-Level tank wastes includes the use of Superlig(reg.sign)639 (SL-639) in a dual column system for removing technetium-99 ({sup 99}Tc) from the aqueous fraction of the waste. This sorbent material has been developed and supplied by IBC Advanced Technologies, Inc., American Fork, UT. This report documents the results of testing the SL-639 sorbent with diluted waste [Na{sup +}] {approx} 5 M from Tank 241-AN-107 (an Envelope C waste, abbreviated AN-107) at Battelle Northwest Laboratories (BNW). The equilibrium behavior was assessed with batch contacts between the sorbent and the waste. Two AN-107 samplesmore » were used: (1) an archived sample from previous testing and (2) a more recent sample collected specifically for BNFL. A portion of the archive sample and all of the BNFL sample were treated to remove Sr-90 and transuranic elements (TRU). All samples had also been Cs decontaminated by ion exchange (IX), and were spiked with a technetium-95m ({sup 95m}Tc) pertechnetate tracer, {sup 95m}TcO{sub 4}{sup -}.The TcO{sub 4}{sup -} and total Tc K{sub d} values, assumed equal to the {sup 95m}Tc and {sup 99}Tc K{sub d}'s, respectively, are shown in Table S1. Values are averages of duplicates, which showed significant scatter. The total Tc K{sub d} for the BNFL sample is much lower than the TcO{sub 4}{sup -}, indicating that a large fraction of the {sup 99}Tc is not pertechnetate.« less
Lee, Hyunjong; Kim, Ji Hyun; Kang, Yeon-koo; Moon, Jae Hoon; So, Young; Lee, Won Woo
2016-01-01
Abstract Objectives: Technetium pertechnetate (99mTcO4) is a radioactive tracer used to assess thyroid function by thyroid uptake system (TUS). However, the TUS often fails to deliver accurate measurements of the percent of thyroid uptake (%thyroid uptake) of 99mTcO4. Here, we investigated the usefulness of quantitative single-photon emission computed tomography/computed tomography (SPECT/CT) after injection of 99mTcO4 in detecting thyroid function abnormalities. Materials and methods: We retrospectively reviewed data from 50 patients (male:female = 15:35; age, 46.2 ± 16.3 years; 17 Graves disease, 13 thyroiditis, and 20 euthyroid). All patients underwent 99mTcO4 quantitative SPECT/CT (185 MBq = 5 mCi), which yielded %thyroid uptake and standardized uptake value (SUV). Twenty-one (10 Graves disease and 11 thyroiditis) of the 50 patients also underwent conventional %thyroid uptake measurements using a TUS. Results: Quantitative SPECT/CT parameters (%thyroid uptake, SUVmean, and SUVmax) were the highest in Graves disease, second highest in euthyroid, and lowest in thyroiditis (P < 0.0001, Kruskal–Wallis test). TUS significantly overestimated the %thyroid uptake compared with SPECT/CT (P < 0.0001, paired t test) because other 99mTcO4 sources in addition to thyroid, such as salivary glands and saliva, contributed to the %thyroid uptake result by TUS, whereas %thyroid uptake, SUVmean and SUVmax from the SPECT/CT were associated with the functional status of thyroid. Conclusions: Quantitative SPECT/CT is more accurate than conventional TUS for measuring 99mTcO4 %thyroid uptake. Quantitative measurements using SPECT/CT may facilitate more accurate assessment of thyroid tracer uptake. PMID:27399139
Lautenschlaeger, Ines E; Hartmann, Antje; Sicken, Julia; Mohrs, Sabrina; Scholz, Volkher B; Neiger, Reto; Kramer, Martin
2013-01-01
Scintigraphy is currently the reference standard for diagnosing feline hyperthyroidism; however, computed tomography (CT) is more widely available in veterinary practice. The purposes of this prospective study were to describe the CT appearance of thyroid glands in cats with hyperthyroidism and compare CT findings with findings from (99m) Tc-pertechnetate scintigraphy. Twenty-five adult hyperthyroid cats were included. Plain CT images were acquired for each cat and the following characteristics recorded for each thyroid lobe: visibility, delineation, position, attenuation, shape, and subjective size. Scintigraphic images were also acquired and the following characteristics recorded: radiopharmaceutical uptake, delineation, ectopic foci, shape, and subjective size. In CT images, thyroid lobes were most commonly found between the second and fourth cervical vertebrae, dorsolateral to the trachea. Affected thyroid lobes (based on scintigraphy reference standard) were most commonly oval and moderately enlarged in CT images. A heterogeneous attenuation pattern (isoattenuating to adjacent soft tissues with hypo- and hyperattenuating foci) was most commonly found in affected thyroid lobes. A positive correlation (P < 0.01) was identified between CT and scintigraphy for left-to-right thyroid lobe size relationship and subjective size of the larger thyroid lobe. The CT estimated mass was significantly higher (median = 148.8; range = [0;357.6]) for the more active thyroid lobe compared to the less active thyroid lobe (median = 84.6; range = [0;312.3]); (W = 154; P < 0.01). Findings indicated that CT may not reliably differentiate unilateral vs. bilateral hyperthyroidism in cats; however, CT may be a reliable alternative test for correctly identifying the more active thyroid lobe. © 2013 Veterinary Radiology & Ultrasound.
Garcia-Pinto, Angélica B.; Santos-Filho, Sebastião D.; Carvalho, Jorge J.; Pereira, Mário J. S.; Fonseca, Adenilson S.; Bernardo-Filho, Mário
2013-01-01
Background: Natural products might alter the labeling of blood constituents with technetium-99m (99mTc) and these results may be correlated with modifications of the shape of the red blood cells (RBC). The biodistribution of radiopharmaceuticals can be also altered. Objective: This investigation aimed to determine biological effects of an aqueous extract of chamomile (CE). Materials and Methods: To study the effect of the CE on the labeling of blood constituents with 99mTc, in vitro and in vivo assays were performed. The effect of the CE on the morphology of RBC was observed under light microscope. The images were acquired, processed, and the perimeter/area ratio of the RBC determined. To analyze the effect of the CE on biodistribution of the sodium pertechnetate (Na99mTcO4) in Wistar rats, these animals were treated or not with a CE. Na99mTcO4 was injected, the rats were sacrificed, the organs were removed, weighted and percentage of radioactivity/gram calculated. Result: In the in vitro experiment, the radioactivity on blood cells compartment and on insoluble fractions of plasma was diminished. The shape and the perimeter/area ratio of the RBC were altered in in vitro assays. An increase of the percentage of radioactivity of Na99mTcO4 was observed in stomach after in vivo treatment. Conclusion: These results could be due to substances of the CE or by the products of the metabolism of this extract in the animal organism. These findings are examples of drug interaction with a radiopharmaceutical, which could lead to misdiagnosis in clinical practice with unexpected consequences. PMID:24143045
Influence of chronic exposure to cold environment on thyroid gland function in rabbits.
Mustafa, S; Elgazzar, A
2014-07-01
Chronic exposure to cold can affect the thyroid gland. However, the effect on thyroid gland perfusion images and the ratio between thyroid hormones secretion were not addressed in any previous study. The present study investigates the effects of chronic cold exposure on thyroid gland function using radionuclide tracer and thyroid hormones secretion concentration. New Zealand white rabbits weighing approximately 1.8-2 kg were kept in a cold room (4°C) for 7 weeks. Thyroid scintigraphy was performed for cold exposed rabbits and a control rabbit group. Each rabbit was injected with 115 MBq (3.1 mCi) technetium-99m pertechnetate (99mTc pertechnetate). Studies were performed using Gamma camera equipped with a low energy, high resolution, pinhole collimator interfaced with a computer. Static images were acquired 20 min after administration of the radiotracer. Rabbits chronically exposed to cold had less body weights than control. Thyroid gland uptake is higher in rabbits chronically exposed to cold than controls using radionuclide perfusion study. The increase was proportional to the time period, so the increase after 7 weeks was greater than 5 weeks. There is also an increase in free triiodothyronine (FT3) and a decrease in free thyroxine (FT4) values. Our results indicate that thyroid gland uptake is higher in rabbits chronically exposed to cold than control and the increase was proportional to the duration. The decrease in rabbit body weights may be related to the increase in metabolism due to the increase of thyroid hormones. Chronic cold exposure also increased the conversion of T4 to T3, which is more potent in thermogenic effect. © Georg Thieme Verlag KG Stuttgart · New York.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Serne, R. Jeffrey; Westsik, Joseph H.; Williams, Benjamin D.
This report describes the results from long-term laboratory leach tests performed at Pacific Northwest National Laboratory (PNNL) for Washington River Protection Solutions (WRPS) to evaluate the release of key constituents from monoliths of Cast Stone prepared with four simulated low-activity waste (LAW) liquid waste streams. Specific objectives of the Cast Stone long-term leach tests described in this report focused on four activities: 1. Extending the leaching times for selected ongoing EPA-1315 tests on monoliths made with LAW simulants beyond the conventional 63-day time period up to 609 days reported herein (with some tests continuing that will be documented later) inmore » an effort to evaluate long-term leaching properties of Cast Stone to support future performance assessment activities. 2. Starting new EPA-1315 leach tests on archived Cast Stone monoliths made with four LAW simulants using two leachants (deionized water [DIW] and simulated Hanford Integrated Disposal Facility (IDF) Site vadose zone pore water [VZP]). 3. Evaluating the impacts of varying the iodide loading (starting iodide concentrations) in one LAW simulant (7.8 M Na Hanford Tank Waste Operations Simulator (HTWOS) Average) by manufacturing new Cast Stone monoliths and repeating the EPA-1315 leach tests using DIW and the VZP leachants. 4. Evaluating the impacts of using a non-pertechnetate form of Tc that is present in some Hanford tanks. In this activity one LAW simulant (7.8 M Na HTWOS Average) was spiked with a Tc(I)-tricarbonyl gluconate species and then solidified into Cast Stone monoliths. Cured monoliths were leached using the EPA-1315 leach protocol with DIW and VZP. The leach results for the Tc-Gluconate Cast Stone monoliths were compared to Cast Stone monoliths pertechnetate.« less
Erdoğan, Alihan; Günay, Emel Ceylan; Gündoğdu, Gökhan; Avlan, Dincer
2011-01-01
A 8 month old boy suffering from inconsolable cry and tenderness presented to our hospital. Ten hours had passed from the onset of his symptoms. Physical examination showed a tender mass on the left groin. Patient was evaluated with Doppler ultrasound and Technetium-99m pertechnetate testicular scintigraphy Differential diagnosis of torsion and inflammatory disease could not be made by adjunctive tests. The patient underwent surgery based on clinical findings and necrotic inguinal left gonad was shown. In this study, we discussed the scintigraphic pattern in a patient with torsion in undescended inguinal testicle Conflict of interest:None declared. PMID:23486731
Process for recovering pertechnetate ions from an aqueous solution also containing other ions
Rogers, Robin; Horwitz, E. Philip; Bond, Andrew H.
1997-01-01
A solid/liquid process for the separation and recovery of TcO.sub.4.sup.-1 ions from an aqueous solution is disclosed. The solid support comprises separation particles having surface-bonded poly(ethylene glycol) groups; whereas the aqueous solution from which the TcO.sub.4.sup.-1 ions are separated contains a poly(ethylene glycol) liquid/liquid biphase-forming amount of a dissolved salt. A solid/liquid phase admixture of separation particles containing bound TcO.sub.4.sup.-1 ions in such an aqueous solution that is free from MoO.sub.4.sup.-2 ions is also contemplated, as is a chromatography apparatus containing that solid/liquid phase admixture.
Laparoscopic approach to Meckel's diverticulum.
Papparella, Alfonso; Nino, Fabiano; Noviello, Carmine; Marte, Antonio; Parmeggiani, Pio; Martino, Ascanio; Cobellis, Giovanni
2014-07-07
To retrospective review the laparoscopic management of Meckel Diverticulum (MD) in two Italian Pediatric Surgery Centers. Between January 2002 and December 2012, 19 trans-umbilical laparoscopic-assisted (TULA) procedures were performed for suspected MD. The children were hospitalized for gastrointestinal bleeding and/or recurrent abdominal pain. Median age at diagnosis was 5.4 years (range 6 mo-15 years). The study included 15 boys and 4 girls. All patients underwent clinical examination, routine laboratory tests, abdominal ultrasound and technetium-99m pertechnetate scan, and patients with bleeding underwent gastrointestinal endoscopy. The abdominal exploration was performed with a 10 mm operative laparoscope. Pneumoperitoneum was established based on the body weight. Systematic overview of the peritoneal cavity allowed the ileum to be grasped with an atraumatic instrument. The complete exploration and surgical treatment of MD were performed extracorporeally, after intestinal exteriorization through the umbilicus. All patients' demographics, main clinical features, diagnostic investigations, operative time, histopathology reports, conversion rate, hospital stay and complications were registered and analyzed. MD was identified in 17 patients, while 1 had an ileal duplication and 1 a jejunal hemangioma. Fifteen patients had painless intestinal bleeding, while 4 had recurrent abdominal pain and exhibited cyst like structures in an ultrasound study. Eleven patients had a positive technetium-99m pertechnetate scan. In the patients with bleeding, gastrointestinal endoscopy did not name the source of hemorrhage. All patients were subjected to a TULA surgical procedure. An intestinal resection/anastomosis was performed in 14 patients, while 4 had a wedge resection of the diverticulum and 1 underwent stapling diverticulectomy. All surgical procedures were performed without conversion to open laparotomy. Mean operative time was 75 min (range 40-115 min). No major surgical complications were recorded. The median hospital stay was 5-7 d (range 4-13 d). All patients are asymptomatic at a median follow up of 4, 5 years (range 10 mo-10 years). Trans-umbilical laparoscopic-assisted Meckel's diverticulectomy is safe and effective in the treatment of MD, with excellent results.
Kim, Ji-Young; Kim, Ji Hyun; Moon, Jae Hoon; Kim, Kyoung Min; Oh, Tae Jung; Lee, Dong-Hwa; So, Young; Lee, Won Woo
2018-01-01
Quantitative parameters from Tc-99m pertechnetate single-photon emission computed tomography/computed tomography (SPECT/CT) are emerging as novel diagnostic markers for functional thyroid diseases. We intended to assess the utility of SPECT/CT parameters in patients with destructive thyroiditis. Thirty-five destructive thyroiditis patients (7 males and 28 females; mean age, 47.3 ± 13.0 years) and 20 euthyroid patients (6 males and 14 females; mean age, 45.0 ± 14.8 years) who underwent Tc-99m pertechnetate quantitative SPECT/CT were retrospectively enrolled. Quantitative parameters from the SPECT/CT (%uptake, standardized uptake value [SUV], thyroid volume, and functional thyroid mass [SUVmean × thyroid volume]) and thyroid hormone levels were investigated to assess correlations and predict the prognosis for destructive thyroiditis. The occurrence of hypothyroidism was the outcome for prognosis. All the SPECT/CT quantitative parameters were significantly lower in the 35 destructive thyroiditis patients compared to the 20 euthyroid patients using the same SPECT/CT scanner and protocol ( p < 0.001 for all parameters). T3 and free T4 did not correlate with any SPECT/CT parameters, but thyroid-stimulating hormone (TSH) significantly correlated with %uptake ( p = 0.004), SUVmean ( p < 0.001), SUVmax ( p = 0.002), and functional thyroid mass ( p < 0.001). Of the 35 destructive thyroiditis patients, 16 progressed to hypothyroidism. On univariate and multivariate analyses, only T3 levels were associated with the later occurrence of hypothyroidism ( p = 0.002, exp(β) = 1.022, 95% confidence interval: 1.008 - 1.035). Novel quantitative SPECT/CT parameters could discriminate patients with destructive thyroiditis from euthyroid patients, suggesting the robustness of the quantitative SPECT/CT approach. However, disease progression of destructive thyroiditis could not be predicted using the parameters, as these only correlated with TSH, but not with T3, the sole predictor of the later occurrence of hypothyroidism.
Kim, Ji-Young; Kim, Ji Hyun; Moon, Jae Hoon; Kim, Kyoung Min; Oh, Tae Jung; Lee, Dong-Hwa; So, Young
2018-01-01
Objective Quantitative parameters from Tc-99m pertechnetate single-photon emission computed tomography/computed tomography (SPECT/CT) are emerging as novel diagnostic markers for functional thyroid diseases. We intended to assess the utility of SPECT/CT parameters in patients with destructive thyroiditis. Materials and Methods Thirty-five destructive thyroiditis patients (7 males and 28 females; mean age, 47.3 ± 13.0 years) and 20 euthyroid patients (6 males and 14 females; mean age, 45.0 ± 14.8 years) who underwent Tc-99m pertechnetate quantitative SPECT/CT were retrospectively enrolled. Quantitative parameters from the SPECT/CT (%uptake, standardized uptake value [SUV], thyroid volume, and functional thyroid mass [SUVmean × thyroid volume]) and thyroid hormone levels were investigated to assess correlations and predict the prognosis for destructive thyroiditis. The occurrence of hypothyroidism was the outcome for prognosis. Results All the SPECT/CT quantitative parameters were significantly lower in the 35 destructive thyroiditis patients compared to the 20 euthyroid patients using the same SPECT/CT scanner and protocol (p < 0.001 for all parameters). T3 and free T4 did not correlate with any SPECT/CT parameters, but thyroid-stimulating hormone (TSH) significantly correlated with %uptake (p = 0.004), SUVmean (p < 0.001), SUVmax (p = 0.002), and functional thyroid mass (p < 0.001). Of the 35 destructive thyroiditis patients, 16 progressed to hypothyroidism. On univariate and multivariate analyses, only T3 levels were associated with the later occurrence of hypothyroidism (p = 0.002, exp(β) = 1.022, 95% confidence interval: 1.008 – 1.035). Conclusion Novel quantitative SPECT/CT parameters could discriminate patients with destructive thyroiditis from euthyroid patients, suggesting the robustness of the quantitative SPECT/CT approach. However, disease progression of destructive thyroiditis could not be predicted using the parameters, as these only correlated with TSH, but not with T3, the sole predictor of the later occurrence of hypothyroidism. PMID:29713225
TIRADS for sonographic assessment of hypofunctioning and indifferent thyroid nodules.
Schenke, Simone; Rink, T; Zimny, M
2015-01-01
To test the feasibility of the Thyroid Imaging Reporting And Data System (TIRADS) according to Horvath and Kwak for the assessment of thyroid nodules. Retrospective analysis of patients with thyroid nodules applying the following inclusion criteria: B-mode-ultrasound, surgery and histological results. Thyroid nodules were classified as TIRADS 2, 3, 4A, 4B, 4C, 5 and 6. A total of 172 patients were included (133 women, 48 ± 13 years, 39 men, 49 ± 11 years) with 222 thyroid nodules (24.9 ± 11.5 mm). Final histological diagnosis revealed 203 benign nodules (91%) and 19 malignant nodules (9%; 18 papillary thyroid carcinoma, PTC, and one medullary thyroid carcinoma, MTC). One hundred and sixty thyroid nodules were hypofunctioning in 99mTc-pertechnetate-scintigraphy, 14 nodules were hyperfunctioning and 46 nodules were classified as indifferent. In two cases with small carcinoma < 1 cm 99mTc-pertechnetate-scintigraphy was not performed. According to Horvath, the prevalence of malignancy was 6.7% in TIRADS 2, 0% in 3, 1.9% in 4A, 33% in 4B, 12.5% in 5 and 100% in 6; 73 nodules (39%) were not clearly classifiable, including 3 carcinoma (4.1%). According to Kwak, the prevalence of malignancy was 6.9% in TIRADS 2, 0% in 3, 2% in 4A, 4.1% in 4B, 23.1% in 4C, and 100% in 5 and 6, respectively. Notably, in the subgroup of hot nodules, 11 (79%) were graded as TIRADS 4A or higher, and thus advisable for fine-needle aspiration biopsy in both TIRADS. The TIRADS described by Horvath is not practicable due to numerous unclassifiable nodules. The revised TIRADS published by Kwak is feasible and suitable to assess the prevalence of malignancy, but it cannot replace scintigraphic imaging. Fine-needle-biopsy is not necessary in nodules categorized as (K)TIRADS 3, 4A and 5.
Senna-Fernandes, Vasco; França, Daisy L. M.; de Souza, Deise; Santos, Kelly C. M.; Sousa, Rafael S.; Manoel, Cristiano V.; Santos-Filho, Sebastião D.; Cortez, Célia M.; Bernardo-Filho, Mario; Guimarães, Marco Antonio M.
2011-01-01
The objective of this study is to investigate the differences of acupuncture effect between the Zusanli (St.36) and Sanyinjiao (SP.6) points on the gastrointestinal-tract (GIT) segment performed by the bioavailability of 99mTc-sodium-pertechnetate (Na99mTcO4) in rats. Male Wistar rats (n = 21) were allocated into three groups of seven each. Group 1 was treated by acupuncture bilaterally at St.36; Group 2 at SP.6; and Group 3 was untreated (control). After 10 min of needle insertion in anesthetized rats, 0.3 mL of Na99mTcO4 (7.4 MBq) was injected via ocular-plexus. After 20 min, the exitus of animals was induced by cervical-dislocation and GIT organs isolated. However, immediately before the exitus procedure, blood was collected by cardiac-puncture for blood radio-labeling (BRL). The radioactivity uptake of the blood constituents was calculated together with the GIT organs by a well gamma counter. The percentage of injected dose per gram of tissue (%ID/g) of Na99mTcO4 was calculated for each GIT organs, while BRL was calculated in %ID. According to the one-way ANOVA, the stomach, jejunum, ileum from the treated groups (Group 1 and Group 2) had significant differences compared to the controls (Group 3). However, between the treated groups (Group 1 and Group 2), there were significant differences (P < .05) in the stomach, jejunum, ileum, cecum, transverse and rectum. In BRL analysis, Group 2 showed significant increase and decrease of the insoluble and soluble fractions of the blood cells, respectively (P < .0001). The authors suggest that St.36 may have a tendency of up-regulation effect on GIT, whereas SP.6, down-regulation effect. However, further rigorous experimental studies to examine the effectiveness of acupuncture in either acupuncture points need to be carried out. PMID:19213853
Process for recovering pertechnetate ions from an aqueous solution also containing other ions
Rogers, R.; Horwitz, E.P.; Bond, A.H.
1997-02-18
A solid/liquid process for the separation and recovery of TcO{sub 4}{sup {minus}1} ions from an aqueous solution is disclosed. The solid support comprises separation particles having surface-bonded poly(ethylene glycol) groups; whereas the aqueous solution from which the TcO{sub 4}{sup {minus}1} ions are separated contains a poly(ethylene glycol) liquid/liquid biphase-forming amount of a dissolved salt. A solid/liquid phase admixture of separation particles containing bound TcO{sub 4}{sup {minus}1} ions in such an aqueous solution that is free from MoO{sub 4}{sup {minus}2} ions is also contemplated, as is a chromatography apparatus containing that solid/liquid phase admixture. 15 figs.
Laparoscopic approach to Meckel's diverticulum
Papparella, Alfonso; Nino, Fabiano; Noviello, Carmine; Marte, Antonio; Parmeggiani, Pio; Martino, Ascanio; Cobellis, Giovanni
2014-01-01
AIM: To retrospective review the laparoscopic management of Meckel Diverticulum (MD) in two Italian Pediatric Surgery Centers. METHODS: Between January 2002 and December 2012, 19 trans-umbilical laparoscopic-assisted (TULA) procedures were performed for suspected MD. The children were hospitalized for gastrointestinal bleeding and/or recurrent abdominal pain. Median age at diagnosis was 5.4 years (range 6 mo-15 years). The study included 15 boys and 4 girls. All patients underwent clinical examination, routine laboratory tests, abdominal ultrasound and technetium-99m pertechnetate scan, and patients with bleeding underwent gastrointestinal endoscopy. The abdominal exploration was performed with a 10 mm operative laparoscope. Pneumoperitoneum was established based on the body weight. Systematic overview of the peritoneal cavity allowed the ileum to be grasped with an atraumatic instrument. The complete exploration and surgical treatment of MD were performed extracorporeally, after intestinal exteriorization through the umbilicus. All patients’ demographics, main clinical features, diagnostic investigations, operative time, histopathology reports, conversion rate, hospital stay and complications were registered and analyzed. RESULTS: MD was identified in 17 patients, while 1 had an ileal duplication and 1 a jejunal hemangioma. Fifteen patients had painless intestinal bleeding, while 4 had recurrent abdominal pain and exhibited cyst like structures in an ultrasound study. Eleven patients had a positive technetium-99m pertechnetate scan. In the patients with bleeding, gastrointestinal endoscopy did not name the source of hemorrhage. All patients were subjected to a TULA surgical procedure. An intestinal resection/anastomosis was performed in 14 patients, while 4 had a wedge resection of the diverticulum and 1 underwent stapling diverticulectomy. All surgical procedures were performed without conversion to open laparotomy. Mean operative time was 75 min (range 40-115 min). No major surgical complications were recorded. The median hospital stay was 5-7 d (range 4-13 d). All patients are asymptomatic at a median follow up of 4, 5 years (range 10 mo-10 years). CONCLUSION: Trans-umbilical laparoscopic-assisted Meckel’s diverticulectomy is safe and effective in the treatment of MD, with excellent results. PMID:25009390
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wiersinga, W.M.; Touber, J.L.; Trip, M.D.
1986-08-01
Iodine excess is associated with a low thyroidal radioiodine uptake due to dilution of the radioisotope by the increased stable iodide pool. We studied thyroidal uptake of radioisotopes in cardiac patients with iodine excess due to amiodarone treatment. /sup 99m/Tc-pertechnetate scintigraphy was performed in 13 patients receiving long term amiodarone therapy. Five patients had a clearly visible thyroid gland, and 8 patients had no or a very faint thyroid image. All patients with positive scans had an increased plasma TSH level, whereas all patients with negative scans had a normal or absent TSH response to TRH. Thyroidal uptake and dischargemore » of 123I were studied in 30 other patients. Group I (n = 11) had normal plasma TSH responses to TRH and no iodine excess, group II (n = 7) had normal TSH responses to TRH and excess iodine from metrizoate angiography in the previous month, group III (n = 7) had normal or decreased TSH responses to TRH while receiving long term amiodarone therapy, and group IV (n = 5) had increased TSH responses to TRH while receiving long term amiodarone therapy. The mean radioiodine uptake value in group I (5.4 +/- 0.8% (+/- SE) at 60 min) was higher than those in group II (2.3 +/- 0.7%; P = 0.009) and group III (0.8 +/- 0.3%; P = 0.0005), but not different from that in group IV (5.3 +/- 1.2%; P = NS). Radioiodine discharge after perchlorate (expressed as a percentage of the 60 min uptake) in group I (10.1 +/- 2.2%) was lower than those in group II (24.9 +/- 10.6%; P = 0.05) and group III (28.8 +/- 5.3%; P less than 0.005), whereas discharge in group IV (58.0 +/- 6.1%) was greater than those in group II (P less than 0.05) and group III (P less than 0.01). In conclusion, 1) thyroid visualization by /sup 99m/Tc-pertechnetate and thyroid radioiodine uptake during iodine excess are decreased in euthyroid and hyperthyroid patients, but preserved in hypothyroid patients.« less
Concentration of perrhenate and pertechnetate solutions
Knapp, F.F.; Beets, A.L.; Mirzadeh, S.; Guhlke, S.
1998-03-17
A method is described for preparing a concentrated solution of a carrier-free radioisotope which includes the steps of: (a) providing a generator column loaded with a composition containing a parent radioisotope; (b) eluting the generator column with an eluent solution which includes a salt of a weak acid to elute a target daughter radioisotope from the generator column in a first eluate; (c) eluting a cation-exchange column with the first eluate to exchange cations of the salt for hydrogen ions and to elute the target daughter radioisotope and a weak acid in a second eluate; (d) eluting an anion-exchange column with the second eluate to trap and concentrate the target daughter radioisotope and to elute the weak acid solution therefrom; and (e) eluting the concentrated target daughter radioisotope from the anion-exchange column with a saline solution. 1 fig.
Concentration of perrhenate and pertechnetate solutions
Knapp, Furn F.; Beets, Arnold L.; Mirzadeh, Saed; Guhlke, Stefan
1998-01-01
A method of preparing a concentrated solution of a carrier-free radioisotope which includes the steps of: a. providing a generator column loaded with a composition containing a parent radioisotope; b. eluting the generator column with an eluent solution which includes a salt of a weak acid to elute a target daughter radioisotope from the generator column in a first eluate. c. eluting a cation-exchange column with the first eluate to exchange cations of the salt for hydrogen ions and to elute the target daughter radioisotope and a weak acid in a second eluate; d. eluting an anion-exchange column with the second eluate to trap and concentrate the target daughter radioisotope and to elute the weak acid solution therefrom; and e. eluting the concentrated target daughter radioisotope from the anion-exchange column with a saline solution.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rapko, Brian M.
2015-09-30
This report examines the need for actual Hanford tank waste solutions to support tasks in the Technetium Management Program in fiscal year (FY) 2016. One key need is to identify both samples where a majority of the soluble technetium is present as pertechnetate and samples where it is not. The total amount of tank supernatant needed from any given tank waste supernatant was determined by polling the tasks leaders for their technology testing needs in FY16 and then arbitrarily ascribing a 10% process loss associated with consolidation and the Cs-137 removal needed to reduce the dose to a level suitablemore » for testing in radiological fumehoods. These polling results identified a need for approximately 2.1 to 3.6 kg of any particular targeted Hanford tank waste supernatant.« less
Effect of Technetium-99 sources on its retention in low activity waste glass
NASA Astrophysics Data System (ADS)
Luksic, Steven A.; Kim, Dong-Sang; Um, Wooyong; Wang, Guohui; Schweiger, Michael J.; Soderquist, Chuck Z.; Lukens, Wayne; Kruger, Albert A.
2018-05-01
Small-scale crucible melting tests on simulated waste glass were performed with technetium-99 (Tc-99) introduced as different species in a representative low activity waste simulant. The glass saw an increase in Tc-99 retention when TcO2•2H2O and various Tc-minerals containing reduced tetravalent Tc were used compared to tests in which pertechnetate with heptavalent Tc was used. We postulate that the increase of Tc retention is likely caused by different reaction paths for Tc incorporation into glass during early stages of melting, rather than the low volatility of reduced tetravalent Tc compounds, which has been a generally accepted idea. Additional studies are needed to clarify the exact mechanisms relevant to the effect of reduced Tc compounds on Tc incorporation into or volatilization from the glass melt.
Hyperfunctioning solid/trabecular follicular carcinoma of the thyroid gland.
Giovanella, Luca; Fasolini, Fabrizio; Suriano, Sergio; Mazzucchelli, Luca
2010-01-01
A 68-year-old woman with solid/trabecular follicular thyroid carcinoma inside of an autonomously functioning thyroid nodule is described in this paper. The patient was referred to our clinic for swelling of the neck and an increased pulse rate. Ultrasonography showed a slightly hypoechoic nodule in the right lobe of the thyroid. Despite suppressed TSH levels, the (99m)Tc-pertechnetate scan showed a hot area corresponding to the nodule with a suppressed uptake in the remaining thyroid tissue. Histopathological examination of the nodule revealed a solid/trabecular follicular thyroid carcinoma. To the best of our knowledge, this is the first case of hyperfunctioning follicular solid/trabecular carcinoma reported in the literature. Even if a hyperfunctioning thyroid carcinoma is an extremely rare malignancy, careful management is recommended so that a malignancy will not be overlooked in the hot thyroid nodules.
Steroid-Responsive Recurrent Encephalopathy Associated with Subacute Thyroiditis
Chung, Yun Jae; Ahn, Jihyun; Ha, Sam-Yeol; Youn, Young Chul
2008-01-01
Background Steroid-responsive encephalopathy associated with subacute thyroiditis has, to our knowledge, not been reported previously. Case Report A 49-year-old woman was found collapsed and brought to our institution with decreased mentality, dysarthria, and gait disturbance. Brain magnetic resonance imaging and angiography were normal but blood tests revealed thyroid-autoantibody-negative thyrotoxicosis. Results of a 99mtechnetium-pertechnetate scan were compatible with the thyrotoxic phase of subacute thyroiditis. 14-3-3 proteins were detected in cerebrospinal fluid. Her mental status began to improve from the day following steroid administration. Recurrent encephalopathy was found 2 months after the initial admission, which was also effectively treated with steroid. Conclusions We speculate that steroid-responsive recurrent encephalopathy associated with subacute thyroiditis is a subtype of Hashimoto's encephalopathy, and consider that steroid treatment should not be delayed in suspected patients. PMID:19513293
Joint imaging in polymyalgia rheumatica
DOE Office of Scientific and Technical Information (OSTI.GOV)
O'Duffy, J.D.; Wahner, H.W.; Hunder, G.G.
1976-08-01
Technetium pertechnetate joint scintigrams were abnormal in 24 of 25 patients with polymyalgia rheumatica, in all 16 with rheumatoid arthritis, in 4 of 13 with nonarticular rheumatism, but in none of 26 control patients. Abnormal uptake in polymyalgia patients was commonest in shoulders and was less likely to be symmetric than in patients with rheumatoid arthritis, in whom distal joint abnormalities predominated. The pattern of abnormal uptake in polymyalgia rheumatica was not different in those with biopsy-proved giant cell arteritis. Correlation between symptoms and abnormal scintigrams was 72%, and abnormal uptake was present in 81% of joints of patients havingmore » physical abnormalities. Biopsy showed lymphocytic synovitis in the knee of one patient. After treatment the number of abnormal joints declined. These findings suggest that synovitis is common in polymyalgia rheumatica, and that it may account for some or most of the symptoms in this condition.« less
Gastric emptying of enteric-coated tablets
DOE Office of Scientific and Technical Information (OSTI.GOV)
Park, H.M.; Chernish, S.M.; Rosenek, B.D.
1984-03-01
To evaluate the gastric emptying time of pharmaceutical dosage forms in a clinical setting, a relatively simple dual-radionuclide technique was developed. Placebo tablets of six different combinations of shape and size were labeled with indium-111 DTPA and enteric coated. Six volunteers participated in a single-blind and crossover study. Tablets were given in the morning of a fasting stomach with 6 oz of water containing /sup 99m/Tc pertechnetate and continuously observed with a gamma camera. A scintigraph was obtained each minute. The results suggested that the size, shape, or volume of the tablet used in this study had no significant effectmore » in the rate of gastric emptying. The tablets emptied erratically and unpredictably, depending upon their time of arrival in the stomach in relation to the occurrence of interdigestive myoelectric contractions. The method described is a relatively simple and accurate technique to allow one to follow the gastric emptying of tablets.« less
Effect of Technetium-99 sources on its retention in low activity waste glass
Luksic, Steven A.; Kim, Dong Sang; Um, Wooyong; ...
2018-03-02
Small-scale crucible melting tests on simulated waste glass were performed with technetium-99 (Tc-99) introduced as different species in a representative low activity waste simulant. The glass saw an increase in Tc-99 retention when TcO 2∙2H 2O and various Tc-minerals containing reduced tetravalent Tc were used compared to tests in which pertechnetate with heptavalent Tc was used. Here, we postulate that the increase of Tc retention is likely caused by different reaction paths for Tc incorporation into glass during early stages of melting, rather than the low volatility of reduced tetravalent Tc compounds, which has been a generally accepted idea. Finally,more » additional studies are needed to clarify the exact mechanisms relevant to the effect of reduced Tc compounds on Tc incorporation into or volatilization from the glass melt.« less
Effect of Technetium-99 sources on its retention in low activity waste glass
DOE Office of Scientific and Technical Information (OSTI.GOV)
Luksic, Steven A.; Kim, Dong-Sang; Um, Wooyong
Small-scale crucible melting tests on simulated waste glass were performed with technetium-99 (Tc-99) introduced as different species in a representative low activity waste simulant. The glass saw an increase in Tc-99 retention when TcO2∙2H2O and various Tc-minerals containing reduced tetravalent Tc were used compared to tests in which pertechnetate with hexavalent Tc was used. We postulate that the increase of Tc retention is likely caused by different reaction paths for Tc incorporation into glass during early stages of melting, rather than the low volatility of reduced tetravalent Tc compounds, which has been a generally accepted idea. Additional studies are neededmore » to clarify the exact mechanisms relevant to the effect of reduced Tc compounds on Tc incorporation into or volatilization from glass melt.« less
Effect of Technetium-99 sources on its retention in low activity waste glass
DOE Office of Scientific and Technical Information (OSTI.GOV)
Luksic, Steven A.; Kim, Dong Sang; Um, Wooyong
Small-scale crucible melting tests on simulated waste glass were performed with technetium-99 (Tc-99) introduced as different species in a representative low activity waste simulant. The glass saw an increase in Tc-99 retention when TcO 2∙2H 2O and various Tc-minerals containing reduced tetravalent Tc were used compared to tests in which pertechnetate with heptavalent Tc was used. Here, we postulate that the increase of Tc retention is likely caused by different reaction paths for Tc incorporation into glass during early stages of melting, rather than the low volatility of reduced tetravalent Tc compounds, which has been a generally accepted idea. Finally,more » additional studies are needed to clarify the exact mechanisms relevant to the effect of reduced Tc compounds on Tc incorporation into or volatilization from the glass melt.« less
Effect of Technetium-99 sources on its retention in low activity waste glass
DOE Office of Scientific and Technical Information (OSTI.GOV)
Luksic, Steven A.; Kim, Dong-Sang; Um, Wooyong
© 2018 Small-scale crucible melting tests on simulated waste glass were performed with technetium-99 (Tc-99) introduced as different species in a representative low activity waste simulant. The glass saw an increase in Tc-99 retention when TcO 2 ∙2H 2 O and various Tc-minerals containing reduced tetravalent Tc were used compared to tests in which pertechnetate with heptavalent Tc was used. We postulate that the increase of Tc retention is likely caused by different reaction paths for Tc incorporation into glass during early stages of melting, rather than the low volatility of reduced tetravalent Tc compounds, which has been a generallymore » accepted idea. Additional studies are needed to clarify the exact mechanisms relevant to the effect of reduced Tc compounds on Tc incorporation into or volatilization from the glass melt.« less
A Case of Painful Hashimoto Thyroiditis that Mimicked Subacute Thyroiditis
Seo, Hye Mi; Kim, Miyeon; Bae, Jaeseok; Kim, Jo-Heon; Lee, Jeong Won; Lee, Sang Ah; Koh, Gwanpyo
2012-01-01
Hashimoto thyroiditis (HT) is an autoimmune thyroid disorder that usually presents as a diffuse, nontender goiter, whereas subacute thyroiditis (SAT) is an uncommon disease that is characterized by tender thyroid enlargement, transient thyrotoxicosis, and an elevated erythrocyte sedimentation rate (ESR). Very rarely, patients with HT can present with painful, tender goiter or fever, a mimic of SAT. We report a case of painful HT in a 68-year-old woman who presented with pain and tenderness in a chronic goiter. Her ESR was definitely elevated and her thyroid laboratory tests suggested subclinical hypothyroidism of autoimmune origin. 99mTc pertechnetate uptake was markedly decreased. Fine needle aspiration biopsy revealed reactive and polymorphous lymphoid cells and occasional epithelial cells with Hürthle cell changes. Her clinical symptoms showed a dramatic response to glucocorticoid treatment. She became hypothyroid finally and is now on levothyroxine therapy. PMID:22570820
Hyperfunctioning Solid/Trabecular Follicular Carcinoma of the Thyroid Gland
Giovanella, Luca; Fasolini, Fabrizio; Suriano, Sergio; Mazzucchelli, Luca
2010-01-01
A 68-year-old woman with solid/trabecular follicular thyroid carcinoma inside of an autonomously functioning thyroid nodule is described in this paper. The patient was referred to our clinic for swelling of the neck and an increased pulse rate. Ultrasonography showed a slightly hypoechoic nodule in the right lobe of the thyroid. Despite suppressed TSH levels, the 99mTc-pertechnetate scan showed a hot area corresponding to the nodule with a suppressed uptake in the remaining thyroid tissue. Histopathological examination of the nodule revealed a solid/trabecular follicular thyroid carcinoma. To the best of our knowledge, this is the first case of hyperfunctioning follicular solid/trabecular carcinoma reported in the literature. Even if a hyperfunctioning thyroid carcinoma is an extremely rare malignancy, careful management is recommended so that a malignancy will not be overlooked in the hot thyroid nodules. PMID:20847957
Effect of Technetium-99 sources on its retention in low activity waste glass
Luksic, Steven A.; Kim, Dong-Sang; Um, Wooyong; ...
2018-05-01
© 2018 Small-scale crucible melting tests on simulated waste glass were performed with technetium-99 (Tc-99) introduced as different species in a representative low activity waste simulant. The glass saw an increase in Tc-99 retention when TcO 2 ∙2H 2 O and various Tc-minerals containing reduced tetravalent Tc were used compared to tests in which pertechnetate with heptavalent Tc was used. We postulate that the increase of Tc retention is likely caused by different reaction paths for Tc incorporation into glass during early stages of melting, rather than the low volatility of reduced tetravalent Tc compounds, which has been a generallymore » accepted idea. Additional studies are needed to clarify the exact mechanisms relevant to the effect of reduced Tc compounds on Tc incorporation into or volatilization from the glass melt.« less
Hürthle cell carcinoma of the thyroid presenting as thyrotoxicosis.
Karanchi, Harsha; Hamilton, Dale J; Robbins, Richard J
2012-01-01
To report a case of hyperthyroidism associated with Hürthle cell carcinoma and to review the literature regarding this relationship. We describe the clinical, biochemical, radiologic, and pathologic data of a patient with Hürthle cell carcinoma associated with thyrotoxicosis and reversible heart failure. We discuss the mechanistic aspects and review previously reported cases of functional Hürthle cell carcinomas. A 43-year-old woman presented with thyrotoxicosis and nonischemic cardiomyopathy. She had a "hot" nodule in the left lobe of the thyroid on sodium pertechnetate scan. She underwent a left hemithyroidectomy and isthmusectomy. Pathologic findings revealed a minimally invasive Hürthle cell carcinoma. On follow-up, the dilated cardiomyopathy had resolved. The association of thyroid carcinoma with thyrotoxicosis is rare. Some Hürthle cell carcinomas can be functional and lead to thyrotoxicosis. To our knowledge, we present the first case of reversible dilated cardiomyopathy due to thyrotoxicosis originating from Hürthle cell carcinoma.
Bonta, Dacian V; Halkar, Raghuveer K; Alazraki, Naomi
2011-09-01
After the extravasation of a therapeutic dose of (131)I-metaiodobenzylguanidine that produced a radiation burn to a patient's forearm, we instituted a catheter placement verification protocol. Before therapy infusion, proper placement is verified by administering 37 MBq of (99m)Tc-pertechnetate through the catheter, and monitoring activity at the administration site and on the contralateral extremity. A dosimetric model describing both high-rate and low-rate dose components was developed and predicted that the basal epidermal layer received a radiation dose consistent with the observed moist desquamation radiation skin toxicity. No extravasation incidents have occurred since the verification procedure was instituted. To protect against radiation injury from extravasation of therapeutic radionuclides, test administration of a small (99m)Tc dose with probe monitoring of comparable sites in both upper extremities appears to be an effective preventive measure.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kuhl, D.E.; Phelps, M.E.; Engel, J. Jr.
1980-01-01
The ECAT Positron Tomograph was used to scan normal control subjects, stroke patients at various times during recovery, and patients with partial epilepsy during EEG monitoring. /sup 18/F-fluorodeoxyglucose (/sup 18/FDG) and /sup 13/N-Ammonia (/sup 13/NH/sub 3/) were used as indicators of abnormalities in local cerebral glucose utilization (LCMR/sub glc/) and relative perfusion, respectively. Hypometabolism, due to deactivation or minimal damage, was demonstrated with the /sup 18/FDG scan in deep structures and broad zones of cerebral cortex which appeared normal on x-ray CT (XCT) and /sup 99m/Tc pertechnetate scans. In patients with partial epilepsy, who had unilateral or focal electrical abnormalities,more » interictal /sup 18/FDG scan patterns clearly showed localized regions of decreased (20 to 50%) LCMR/sub glc/, which correlated anatomically with the eventual EEG localization.« less
Sodalite as a vehicle to increase Re retention in waste glass simulant during vitrification
DOE Office of Scientific and Technical Information (OSTI.GOV)
Luksic, Steven A.; Riley, Brian J.; Parker, Kent E.
Technetium retention during Hanford waste vitrification can be increased by inhibiting technetium volatility from the waste glass melter. Incorporating technetium into a mineral phase, such as sodalite, is one way to achieve this. Rhenium-bearing sodalite was tested as a vehicle to transport perrhenate (ReO4-), a nonradioactive surrogate for pertechnetate (TcO4-), into high-level (HLW) and low-activity waste (LAW) glasses. After melting feeds of these two glasses, the retention of rhenium was measured and compared with the rhenium retention in glass prepared from a feed containing Re2O7 as a standard. The rhenium retention was 21% higher for HLW glass and 85% highermore » for LAW glass when added to samples in the form of sodalite as opposed to when it was added as Re2O7, demonstrating the efficacy of this type of an approach.« less
Selivanova, Svetlana V; Lavallée, Éric; Senta, Helena; Caouette, Lyne; McEwan, Alexander J B; Guérin, Brigitte; Lecomte, Roger; Turcotte, Éric
2017-05-01
A single-site prospective open-label clinical study with cyclotron-produced sodium 99m Tc-pertechnetate ( 99m Tc-NaTcO 4 ) was performed in patients with indications for a thyroid scan to demonstrate the clinical safety and diagnostic efficacy of the drug and to confirm its equivalence with conventional 99m Tc-NaTcO 4 eluted from a generator. Methods: 99m Tc-NaTcO 4 was produced from enriched 100 Mo (99.815%) with a cyclotron (24 MeV; 2 h of irradiation) or supplied by a commercial manufacturer (bulk vial eluted from a generator). Eleven patients received 325 ± 29 (mean ± SD) MBq of the cyclotron-produced 99m Tc-NaTcO 4 , whereas the age- and sex-matched controls received a comparable amount of the generator-derived tracer. Whole-body and thyroid planar images were obtained for each participant. In addition to the standard-energy window (140.5 keV ± 7.5%), data were acquired in lower-energy (117 keV ± 10%) and higher-energy (170 keV ± 10%) windows. Vital signs and hematologic and biochemical parameters were monitored before and after tracer administration. Results: Cyclotron-produced 99m Tc-NaTcO 4 showed organ and whole-body distributions identical to those of conventional 99m Tc-NaTcO 4 and was well tolerated. All images led to a clear final diagnosis. The fact that the number of counts in the higher-energy window was significantly higher for cyclotron-produced 99m Tc-NaTcO 4 did not influence image quality in the standard-energy window. Image definition in the standard-energy window with cyclotron-produced 99m Tc was equivalent to that with generator-eluted 99m Tc and had no particular features allowing discrimination between the 99m Tc production methods. Conclusion: The systemic distribution, clinical safety, and imaging efficacy of cyclotron-produced 99m Tc-NaTcO 4 in humans provide supporting evidence for the use of this tracer as an equivalent for generator-eluted 99m Tc-NaTcO 4 in routine clinical practice. © 2017 by the Society of Nuclear Medicine and Molecular Imaging.
Development of a remote spectroelectrochemical sensor for technetium as pertechnetate
NASA Astrophysics Data System (ADS)
Monk, David James
Subsurface contamination by technetium (Tc) is of particular concern in the monitoring, characterization, and remediation of underground nuclear waste storage tanks, processing areas, and associated surroundings at the Hanford Site and other U.S. DOE sites nationwide. The concern over this radioactive element arises for two reasons. First, its most common isotope, 99Tc, has an extremely long lifetime of 2.15 x 105 years. Second, it's most common chemical form in environmental conditions, pertechnetate (TcO4-), exhibits very fast migration through soils and readily presents itself to any nearby aquifer. Standard procedures of sampling and analysis in a laboratory prove to be slow and costly in the case of subsurface contamination by radioactive materials. It is highly desirable to develop sensors for these materials that possess the capability of either in-situ or on-site placement for continuous monitoring or immediate analysis of collected samples. These sensors need to possess adequate detection limit and selectivity, rapid response, reversibility (many measurements with one sensor), the ability to perform remotely, and ruggedness. This dissertation describes several areas of the continued work toward a sensor for 99Tc as TcO4-. Research initially focused on developing spectroelectrochemical instrumentation and a disposable sensing element, engineered to address the need to perform remote measurements. The instrument was then tested using samples containing 99Tc, resulting in the development of ancillary equipment and techniques to address concerns associated with performing experiments on radioactive materials. In these tests, the electrochemistry of TcO4 - was demonstrated to be irreversible. Electrochemical reduction of TcO4- on a bare or polymer modified electrode resulted in the continuous build up of technetium oxide (TcO2) on the electrode surface. This TcO2 formed in visual quantities in these films during electrochemistry, and proved to be non-ideal for spectroelectrochemical sensing. In the most recent work described, the development of metal templating techniques using complexes synthesized with rhenium (Re) was investigated as one means to circumvent this irreversibility. In an extension of the metal templating research, custom ligands were being designed which will impart structural rigidity and fluorescence to the template complexes, to facilitate selectivity and sensitivity at levels previously unprecedented for optical techniques.
Skin decontamination cream for radiological contaminants: Formulation development and evaluation
Khan, Abdul Wadood; Kotta, Sabna; Rana, Sudha; Ansari, Shahid Husain; Sharma, Rakesh Kumar; Ali, Javed
2013-01-01
Background: Increased use of the radioactive materials in the field of research, medical, nuclear power plant, and industry has increased the risk of accidental exposure. Intentional use of the radioisotopes by terrorist organizations could cause exposure/contamination of a number of the population. In view of the accidental contamination, there is a need to develop self-usable decontamination formulations that could be used immediately after contamination is suspected. Materials and Methods: Present work was planned to optimize and develop self-usable radiation decontamination cream formulation. Various pharmaceutical parameters were characterized. 99mTc-sodium pertechnetate was used as radiocontaminant. Static counts were recorded before and after decontamination using single photon emission computed tomography. Results: Decontamination efficacy of the cream was found to be 42% ± 3% at 0-0.5 h after the exposure. Primary skin irritancy test was satisfactory as no erythema or edema was observed visually after 2 weeks of the formulation application. Conclusion: The decontamination studies proved the potential of EDTA to remove the radiological contaminants effectively. PMID:23799206
Sodalite as a vehicle to increase Re retention in waste glass simulant during vitrification
NASA Astrophysics Data System (ADS)
Luksic, Steven A.; Riley, Brian J.; Parker, Kent E.; Hrma, Pavel
2016-10-01
Technetium (Tc) retention during Hanford waste vitrification can be increased if the volatility can be controlled. Incorporating Tc into a thermally stable mineral phase, such as sodalite, is one way to achieve increased retention. Here, rhenium (Re)-bearing sodalite was tested as a vehicle to transport perrhenate (ReO4-), a nonradioactive surrogate for pertechnetate (TcO4-), into high-level (HLW) and low-activity waste (LAW) glass simulants. After melting HLW and LAW simulant feeds, the retention of Re in the glass was measured and compared with the Re retention in glass prepared from a feed containing Re2O7. Phase analysis of sodalite in both these glasses across a profile of temperatures describes the durability of Re-sodalite during the feed-to-glass transition. The use of Re sodalite improved the Re retention by 21% for HLW glass and 85% for LAW glass, demonstrating the potential improvement in Tc-retention if TcO4- were to be encapsulated in a Tc-sodalite prior to vitrification.
The function of Sn(II)-apatite as a Tc immobilizing agent
NASA Astrophysics Data System (ADS)
Asmussen, R. Matthew; Neeway, James J.; Lawter, Amanda R.; Levitskaia, Tatiana G.; Lukens, Wayne W.; Qafoku, Nikolla P.
2016-11-01
At the U.S. Department of Energy Hanford Site, Tc-99 is a component of low-activity waste (LAW) fractions of the nuclear tank waste and removal of Tc from LAW streams would greatly benefit the site remediation process. In this study, we investigated the removal of Tc(VII), as pertechnetate, from deionized water (DIW) and a LAW simulant through batch sorption testing and solid phase characterization using tin (II) apatite (Sn-A) and SnCl2. Sn-A showed higher levels of Tc removal from both DIW and LAW simulant. Scanning electron microscopy/energy dispersive X-ray spectroscopy (SEM/XEDS) and X-ray absorption spectroscopy (XAS) of reacted Sn-A in DIW showed that TcO4- is reduced to Tc(IV) on the Sn-A surface. The performance of Sn-A in the LAW simulant was lowered due to a combined effect of the high alkalinity, which lead to an increased dissolution of Sn from the Sn-A, and a preference for the reduction of Cr(VI).
Impeding 99Tc(IV) mobility in novel waste forms
Lee, Mal-Soon; Um, Wooyong; Wang, Guohui; Kruger, Albert A.; Lukens, Wayne W.; Rousseau, Roger; Glezakou, Vassiliki-Alexandra
2016-01-01
Technetium (99Tc) is an abundant, long-lived radioactive fission product whose mobility in the subsurface is largely governed by its oxidation state. Tc immobilization is crucial for radioactive waste management and environmental remediation. Tc(IV) incorporation in spinels has been proposed as a novel method to increase Tc retention in glass waste forms during vitrification. However, experiments under high-temperature and oxic conditions show reoxidation of Tc(IV) to volatile pertechnetate, Tc(VII). Here we examine this problem with ab initio molecular dynamics simulations and propose that, at elevated temperatures, doping with first row transition metal can significantly enhance Tc retention in magnetite in the order Co>Zn>Ni. Experiments with doped spinels at 700 °C provide quantitative confirmation of the theoretical predictions in the same order. This work highlights the power of modern, state-of-the-art simulations to provide essential insights and generate theory-inspired design criteria of complex materials at elevated temperatures. PMID:27357121
Nuclear medicine in clinical neurology: an update
DOE Office of Scientific and Technical Information (OSTI.GOV)
Oldendorf, W.H.
1981-01-01
Isotope scanning using technetium 99m pertechnetate has fallen into disuse since the advent of x-ray computerized tomography. Regional brain blood flow studies have been pursued on a research basis. Increased regional blood flow during focal seizure activity has been demonstrated and is of use in localizing such foci. Cisternography as a predictive tool in normal pressure hydrocephalus is falling into disuse. Positron tomographic scanning is a potent research tool that can demonstrate both regional glycolysis and blood flow. Unfortunately, it is extremely expensive and complex to apply in a clinical setting. With support from the National Institutes of Health, sevenmore » extramural centers have been funded to develop positron tomographic capabilities, and they will greatly advance our knowledge of stroke pathophysiology, seizure disorders, brain tumors, and various degenerative diseases. Nuclear magnetic resonance imaging is a potentially valuable tool since it creates tomographic images representing the distribution of brain water. No tissue ionization is produced, and images comparable to second-generation computerized tomographic scans are already being produced in humans.« less
Removal of Sb-125 and Tc-99 from Liquid Radwaste by Novel Adsorbents
DOE Office of Scientific and Technical Information (OSTI.GOV)
Harjula, R.O.; Koivula, R.; Paajanen, A.
2006-07-01
Novel proprietary metal oxide materials (MOM) have been tested for the removal of Sb-125 from simulated Floor Drain Waters of BWR. Antimony was present in the solutions as oxidized anionic form. Long term column experiment with simulated liquid that showed high Sb-125 removal at least up to 8000 bed volumes. One column experiments was carried out using nonradioactive Sb to exhaust the column. Leaching tests with 1000 ppm boric acid showed that 100 % of absorbed Sb remains in the sorbent material. Column experiments with real Fuel Pond Water from Olkiluoto NPP (BWR) showed reduction of Sb-125 (feed level 400more » Bq/L, 1.10{sup -5} {mu}Ci/mL) below detection limit (MDA = 1.7 Bq/L, 5.10{sup -8},{mu}Ci/mL). Additional experiments have also been carried out with pertechnetate (Tc-99) ions. Results indicate that MOM materials are efficient also for the removal of Tc-99 from concentrated NaNO{sub 3} solution. (authors)« less
A rare cause of hyperthyroidism: functioning thyroid metastases.
Gardner, Daphne; Ho, Su Chin
2014-10-09
Hyperthyroidism is a common medical problem that is readily treated with antithyroid medications. However, attributing the correct aetiology of hyperthyroidism alters management and outcome. We present a case of a 66-year-old woman with a seemingly common problem of hyperthyroidism associated with a goitre, which was initially attributed to a toxic nodule. However, Tc-99m pertechnetate uptake scan and thyroid-stimulating hormone receptor antibody were negative, inconsistent with a toxic nodule or Grave's disease. Her thyroid function tests proved difficult to control over the next few months. She eventually proceeded to a total thyroidectomy and histology revealed follicular variant papillary thyroid carcinoma. She was started on levothyroxine postoperatively but developed severe hyperthyroidism, revealing the cause of hyperthyroidism to be autonomously functioning thyroid metastases. Although functioning thyroid metastases are very rare, they need to be considered among the differential diagnoses of hyperthyroidism, as there are nuances in management that could alter the eventual outcome. 2014 BMJ Publishing Group Ltd.
A solvent-extraction module for cyclotron production of high-purity technetium-99m.
Martini, Petra; Boschi, Alessandra; Cicoria, Gianfranco; Uccelli, Licia; Pasquali, Micòl; Duatti, Adriano; Pupillo, Gaia; Marengo, Mario; Loriggiola, Massimo; Esposito, Juan
2016-12-01
The design and fabrication of a fully-automated, remotely controlled module for the extraction and purification of technetium-99m (Tc-99m), produced by proton bombardment of enriched Mo-100 molybdenum metallic targets in a low-energy medical cyclotron, is here described. After dissolution of the irradiated solid target in hydrogen peroxide, Tc-99m was obtained under the chemical form of 99m TcO 4 - , in high radionuclidic and radiochemical purity, by solvent extraction with methyl ethyl ketone (MEK). The extraction process was accomplished inside a glass column-shaped vial especially designed to allow for an easy automation of the whole procedure. Recovery yields were always >90% of the loaded activity. The final pertechnetate saline solution Na 99m TcO 4 , purified using the automated module here described, is within the Pharmacopoeia quality control parameters and is therefore a valid alternative to generator-produced 99m Tc. The resulting automated module is cost-effective and easily replicable for in-house production of high-purity Tc-99m by cyclotrons. Copyright © 2016 Elsevier Ltd. All rights reserved.
van Hoek, Ingrid M; Vandermeulen, Eva; Peremans, Kathelijne; Daminet, Sylvie
2010-02-01
This study investigated the recombinant human thyrotropin (rhTSH) stimulation test in healthy cats (group 1), cats with non-thyroidal illness (group 2) and cats with low serum total T(4) (TT(4)) and azotaemia after (131)I treatment (group 3). Serum TT(4) responses and thyroidal pertechnetate uptake after administration of 25 microg rhTSH IV were assessed. Baseline serum TT(4) was significantly lower in group 3 compared with group 1, but not between other group pairs. Serum TT(4) increased significantly in groups 1 and 2 but not in group 3 after rhTSH administration. Post-rhTSH serum TT(4) concentrations differed significantly between groups 1 and 3 and groups 2 and 3, but not between groups 1 and 2. Thyroid/salivary gland uptake ratio (T/S uptake ratio) differed only significantly between groups 1 and 3. Stimulation with rhTSH is valuable to differentiate euthyroidism from iatrogenic hypothyroidism in cats. Copyright 2009 ESFM and AAFP. Published by Elsevier Ltd. All rights reserved.
Redox-dependent solubility of technetium in low activity waste glass
NASA Astrophysics Data System (ADS)
Soderquist, Chuck Z.; Schweiger, Michael J.; Kim, Dong-Sang; Lukens, Wayne W.; McCloy, John S.
2014-06-01
The solubility of technetium was measured in a Hanford low activity waste (LAW) glass simulant, to investigate the extent that technetium solubility controls the incorporation of technetium into LAW glass. A series of LAW glass samples, spiked with 500-6000 ppm of Tc as potassium pertechnetate, were melted at 1000 °C in sealed fused quartz ampoules. Technetium solubility was determined in the quenched bulk glass to be 2000-2800 ppm, with slightly reducing conditions due to choice of milling media resulting in reductant contamination and higher solubility. The chemical form of technetium obtained by X-ray absorption near edge spectroscopy is mainly isolated, octahedrally-coordinated Tc(IV), with a minority of Tc(VII) in some glasses and TcO2 in two glasses. The concentration and speciation of technetium depends on glass redox and amount of technetium added. Salts formed at the top of higher technetium loaded glasses during the melt. The results of this study show that technetium solubility should not be a factor in technetium retention during melting of Hanford LAW glass.
Zirconium-Based Metal–Organic Framework for Removal of Perrhenate from Water
DOE Office of Scientific and Technical Information (OSTI.GOV)
Banerjee, Debasis; Xu, Wenqian; Nie, Zimin
2016-09-06
Efficient removal of pertechnetate (TcO4-) anions from liquid waste or melter off-gas solution for alternative treatment is one of the promising options to manage 99Tc in legacy nuclear waste. Safe immobilization of 99Tc is of major importance due to its long half-life (t1/2= 2.13 × 105 yrs) and environmental mobility. Different types of inorganic and solid state ion-exchange materials such as layered double hydroxides have been shown to absorb TcO4- anions from water. However, both high capacity and selectivity have yet to be achieved in a single material. Herein, we show that a protonated version of an ultra-stable zirconium basedmore » metal-organic framework can adsorb perrhenate (ReO4-) anions, a non-radioactive sur-rogate for TcO4-, from water even in the presence of other common anions. Synchrotron based powder X-ray diffraction and molecular simulations were used to identify the position of the adsorbed ReO4- (surrogate for TcO4-) molecule within the framework.« less
Çeliker, Metin; Beyazal Çeliker, Fatma; Turan, Arzu; Beyazal, Mehmet; Beyazal Polat, Hatice
2015-01-01
Ectopic thyroid can be encountered anywhere between the base of tongue and pretracheal region. The most common form is euthyroid neck mass. Herein, we aimed to present the findings of a female case with ectopic thyroid tissue localized in the left submandibular region. A 44-year-old female patient, who underwent bilateral subtotal thyroidectomy four years ago with the diagnosis of multinodular goiter, was admitted to our hospital due to a mass localized in the left submandibular area that gradually increased in the last six months. Neck ultrasonography, contrast-enhanced computed tomography, and scintigraphic examination were performed on the patient. On thyroid scintigraphy with Tc-99m pertechnetate, thyroid tissue activity uptake showing massive radioactivity was observed in the normal localization of the thyroid gland and in the submandibular localization. The focus in the submandibular region was excised. Pathological examination of the specimen showed normal thyroid follicle cells with no signs of malignancy. The submandibular mass is a rarely encountered lateral ectopic thyroid tissue. Accordingly, ectopic thyroid tissue should also be considered in the differential diagnosis of masses in the submandibular region. PMID:26634164
Impeding 99Tc(IV) mobility in novel waste forms
Lee, Mal-Soon; Um, Wooyong; Wang, Guohui; ...
2016-06-30
Technetium ( 99Tc) is a long-lived radioactive fission product whose mobility in the subsurface is largely governed by its oxidation state1. Immobilization of Tc in mineral substrates is crucial for radioactive waste management and environmental remediation. Tc(IV) incorporation in spinels2, 3 has been proposed as a novel method to increase Tc retention in glass waste forms. However, experiments with Tc-magnetite under high temperature and oxic conditions showed re-oxidation of Tc(IV) to volatile pertechnetate Tc(VII)O4-.4, 5 Here we address this problem with large-scale ab initio molecular dynamics simulations and propose that elevated temperatures, 1st row transition metal dopants can significantly enhancemore » Tc retention in the order Co > Zn > Ni. Experiments with doped spinels at T=700 ºC provided quantitative confirmation of increased Tc retention in the same order predicted by theory. This work highlights the power of modern state-of-the-art simulations to provide essential insights and generate bottom-up design criteria of complex oxide materials at elevated temperatures.« less
Development Of ABEC Column For Separation Of Tc-99 From Northstar Dissolved Target Solution
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stepinski, Dominique C.; Bennett, Megan E.; Naik, Seema R.
Batch and column breakthrough experiments were performed to determine isotherms and mass-transfer parameters for adsorption of Tc on aqueous biphasic extraction chromatographic (ABEC) sorbent in two solutions: 200 g/L Mo, 5.1 M K +, 1 M OH -, and 0.1 M NO 3 - (Solution A) and 200 g/L Mo, 9.3 M K +, 5 M OH -, and 0.1 M NO 3 - (Solution B). Good agreement was found between the isotherm values obtained by batch and column breakthrough studies for both Solutions A and B. Potassium-pertechnetate intra-particle diffusivity on ABEC resin was estimated by VERSE simulations, and goodmore » agreement was found among a series of column-breakthrough experiments at varying flow velocities, column sizes, and technetium concentrations. However, testing of 10 cc cartridges provided by NorthStar with Solutions A and B did not give satisfactory results, as significant Tc breakthrough was observed and ABEC cartridge performance varied widely among experiments. These different experimental results are believed to be due to inconsistent preparation of the ABEC resin prior to packing and/or inconsistent packing.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Burton-Pye, Benjamin P.; Radivojevic, Ivana; McGregor, Donna
2011-11-23
Technetium-99 ( 99Tc)(β - max: 293.7 keV; t 1/2: 2.1 x 10 5 years) is a byproduct of uranium-235 fission and comprises a large component of radioactive waste. Under aerobic conditions and in a neutral- basic environment, the pertechnetate anion ( 99TcO 4 -) is stable. 99TcO 4 - is very soluble, migrates easily through the environment and does not sorb well onto mineral surfaces, soils or sediments. This study moves forward a new strategy for the reduction of TcO 4 - and chemical incorporation of the reduced 99Tc into a metal oxide material. This strategy employs a single material,more » a polyoxometalate (POM), α 2-[P 2W 17O 61] 10-, that can be photoactivated in the presence of 2-propanol to transfer electrons to TcO 4 - and incorporate the reduced 99Tc covalently into the α 2 - framework to form the Tc VO species, Tc VO(α 2-P 2W 17O 61) 7-. This occurs via the formation of an intermediate species that slowly converts to Tc VO(α 2-P 2W 17O 61) 7-. EXAFS and XANES analysis and preliminary EPR analysis, suggests that the intermediate consists of a Tc(IV) α 2- species where the 99Tc is likely bound to only 2 of the 4 W-O oxygen atoms in the α 2-[P 2W 17O 61] 10- defect. This intermediate then oxidizes and converts to the 99Tc VO(α 2-P 2W 17O 61) 7- product. The reduction and incorporation of 99TcO 4- was accomplished in a ''one pot'' reaction using both sunlight and UV irradiation, and monitored as a function of time using multinuclear NMR and radio TLC. The process was further probed by the ''step-wise'' generation of reduced α 2-P 2W 17O 61 12- through bulk electrolysis followed by the addition of TcO 4 -. The reduction and incorporation of ReO 4 -, as a non-radioactive surrogate for 99Tc, does not proceed through the intermediate species, and Re VO is incorporated quickly into the α 2-[P 2W 17O 61] 10- defect. These observations are consistent with the periodic trends of 99Tc and Re. Specifically, 99Tc is more easily reduced compared to Re. In addition to serving as models for metal oxides, POMs may also provide a suitable platform to study the molecular level dynamics and mechanisms of the reduction and incorporation of Tc into a material.« less
Gomes, Guilherme Francisco; Bonin, Eduardo Aimore; Noda, Rafael William; Cavazzola, Leandro Totti; Bartholomei, Thiago Ferreira
2016-01-01
Meckel’s diverticulum (MD) is estimated to affect 1%-2% of the general population, and it represents a clinically silent finding of a congenital anomaly in up to 85% of the cases. In adults, MD may cause symptoms, such as overt occult lower gastrointestinal bleeding. The diagnostic imaging workup includes computed tomography scan, magnetic resonance imaging enterography, technetium 99m scintigraphy (99mTc) using either labeled red blood cells or pertechnetate (known as the Meckel’s scan) and angiography. The preoperative detection rate of MD in adults is low, and many patients ultimately undergo exploratory laparoscopy. More recently, however, endoscopic identification of MD has been possible with the use of balloon-assisted enteroscopy via direct luminal access, which also provides visualization of the diverticular ostium. The aim of this study was to review the diagnosis by double-balloon enteroscopy of 4 adults with symptomatic MD but who had negative diagnostic imaging workups. These cases indicate that balloon-assisted enteroscopy is a valuable diagnostic method and should be considered in adult patients who have suspected MD and indefinite findings on diagnostic imaging workup, including negative Meckel’s scan. PMID:27803776
Measurement of Absorbed Dose from Radionuclide Solutions Mixed Intimately with the Fbx Dosimeter.
NASA Astrophysics Data System (ADS)
Benedetto, Anthony Richard
Chemical dosimeters are used widely for accurate measurement of large radiation doses due to external beam irradiation from radioisotope sources and from particle accelerators. Their use for measurement of absorbed doses from radioactive solutions mixed in the dosimeter solution was reported as early as 1952, but the large activities needed to produce suitable absorbance values in the relatively insensitive dosimeters of that time discouraged further work. This manuscript reports the results of an investigation into the suitability of the ferrous sulfate-benzoic acid -xylenol orange (FBX) dosimeter for measurement of small absorbed doses caused by radionuclide solutions dissolved in the dosimeter solution. The FBX dosimeter exhibited a linear dose response as a function of activity for two common radiopharmaceuticals, technetium-99m sodium pertechnetate and iodine-131 sodium iodide. Conditions under which the FBX dosimeter may be used with radionuclide solutions were studied and were found to be amenable to routine use by laboratories possessing relatively unsophisticated instrumentation. It appears likely that any radionuclide could be studied using this dosimeter. Finally, potential applications and future research work are suggested, including measurement of absorbed dose from radiopharmaceuticals using realistic human-like phantoms to assess the risk from clinical nuclear medicine studies.
Konopka, Allan; Plymale, Andrew E; Carvajal, Denny A; Lin, Xueju; McKinley, James P
2013-11-01
Aquifer microbes in the 300 Area of the Hanford Site in southeastern Washington State, USA, are located in an oligotrophic environment and are periodically exposed to U(VI) concentrations that can range up to 10 μM in small sediment fractures. Assays of (3)H-leucine incorporation indicated that both sediment-associated and planktonic microbes were metabolically active, and that organic C was growth-limiting in the sediments. Although bacteria suspended in native groundwater retained high activity when exposed to 100 μM U(VI), they were inhibited by U(VI) <1 μM in synthetic groundwater that lacked added bicarbonate. Chemical speciation modeling suggested that positively charged species and particularly (UO2)3(OH)5 (+) rose in concentration as more U(VI) was added to synthetic groundwater, but that carbonate complexes dominated U(VI) speciation in natural groundwater. U toxicity was relieved when increasing amounts of bicarbonate were added to synthetic groundwater containing 4.5 μM U(VI). Pertechnetate, an oxyanion that is another contaminant of concern at the Hanford Site, was not toxic to groundwater microbes at concentrations up to 125 μM.
Molecular Imaging of Conscious, Unrestrained Mice with AwakeSPECT
DOE Office of Scientific and Technical Information (OSTI.GOV)
Baba, Justin S; Endres, Christopher; Foss, Catherine
2013-01-01
We have developed a SPECT imaging system, AwakeSPECT, to enable molecular brain imaging of untrained mice that are conscious, unanesthetized, and unrestrained. We accomplished this with head tracking and motion correction techniques. Methods: The capability of the system for motion-corrected imaging was demonstrated with a 99mTc-pertechnetate phantom, 99mTcmethylene diphosphonate bone imaging, and measurement of the binding potential of the dopamine transporter radioligand 123I-ioflupane in mouse brain in the awake and anesthetized (isoflurane) states. Stress induced by imaging in the awake state was assessed through measurement of plasma corticosterone levels. Results: AwakeSPECT provided high-resolution bone images reminiscent of those obtained frommore » CT. The binding potential of 123I-ioflupane in the awake state was on the order of 50% of that obtained with the animal under anesthesia, consistent with previous studies in nonhuman primates. Levels of stress induced were on the order of those seen in other behavioral tasks and imaging studies of awake animals. Conclusion: These results demonstrate the feasibility of SPECT molecular brain imaging of mice in the conscious, unrestrained state and demonstrate the effects of isoflurane anesthesia on radiotracer uptake.« less
Molecular Imaging of Conscious, Unrestrained Mice with AwakeSPECT
DOE Office of Scientific and Technical Information (OSTI.GOV)
Baba, Justin S.; Endres, Christopher J.; Foss, Catherine A.
2013-06-01
We have developed a SPECT imaging system, AwakeSPECT, to enable molecular brain imaging of untrained mice that are conscious, unanesthetized, and unrestrained. We accomplished this with head tracking and motion correction techniques. Methods: The capability of the system for motion-corrected imaging was demonstrated with a ^99mTc-pertechnetate phantom, ^99mTc-methylene diphosphonate bone imaging, and measurement of the binding potential of the dopamine transporter radioligand ^123I-ioflupane in mouse brain in the awake and anesthetized (isoflurane) states. Stress induced by imaging in the awake state was assessed through measurement of plasma corticosterone levels. Results: AwakeSPECT provided high-resolution bone images reminiscent of those obtained frommore » CT. The binding potential of ^123I-ioflupane in the awake state was on the order of 50% of that obtained with the animal under anesthesia, consistent with previous studies in nonhuman primates. Levels of stress induced were on the order of those seen in other behavioral tasks and imaging studies of awake animals. Conclusion: These results demonstrate the feasibility of SPECT molecular brain imaging of mice in the conscious, unrestrained state and demonstrate the effects of isoflurane anesthesia on radiotracer uptake.« less
Radioactive excretion in human milk following administration of /sup 99m/Tc macroaggregated albumin
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pittard, W.B.; Merkatz, R.; Fletcher, B.D.
Albumin-tagged sodium pertechnetate (technetium) is routinely used in nuclear medicine for scanning procedures of the lung. The rate of excretion of this radionuclide into breast milk and the resultant potential radiation hazard to the nursing infant have received little attention. Therefore the milk from a nursing mother who required a lung scan because of suspected pulmonary emboli using an intravenous injection of 4 mCi of /sup 99m/Tc macroaggregated human serum albumin was monitored. Albumin tagging severely limited the entrance of technetium into her milk and the radioactivity of the milk returned to base line by 24 hours. A total ofmore » 2.02 muCi of technetium was measured in the 24-hour milk collection after technetium injection and 94% of this amount was excreted by 15.5 hours. This amount of technetium administered orally to a newborn would deliver a total body radiation dose of .3 mrad. Therefore, an infant would receive trivial doses of radiation if breast-feeding were resumed 15.5 hours after administration of the radionuclide to the mother and nursing can clearly be resumed safely 24 hours after injection.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nash, Charles A.; Hamm, L. Larry; Smith, Frank G.
2014-12-19
The primary treatment of the tank waste at the DOE Hanford site will be done in the Waste Treatment and Immobilization Plant (WTP) that is currently under construction. The baseline plan for this facility is to treat the waste, splitting it into High Level Waste (HLW) and Low Activity Waste (LAW). Both waste streams are then separately vitrified as glass and poured into canisters for disposition. The LAW glass will be disposed onsite in the Integrated Disposal Facility (IDF). There are currently no plans to treat the waste to remove technetium, so its disposition path is the LAW glass. Duemore » to the water solubility properties of pertechnetate and long half-life of 99Tc, effective management of 99Tc is important to the overall success of the Hanford River Protection Project mission. To achieve the full target WTP throughput, additional LAW immobilization capacity is needed, and options are being explored to immobilize the supplemental LAW portion of the tank waste. Removal of 99Tc, followed by off-site disposal, would eliminate a key risk contributor for the IDF Performance Assessment (PA) for supplemental waste forms, and has potential to reduce treatment and disposal costs. Washington River Protection Solutions (WRPS) is developing some conceptual flow sheets for supplemental LAW treatment and disposal that could benefit from technetium removal. One of these flowsheets will specifically examine removing 99Tc from the LAW feed stream to supplemental immobilization. To enable an informed decision regarding the viability of technetium removal, further maturation of available technologies is being performed. This report contains results of experimental ion exchange distribution coefficient testing and computer modeling using the resin SuperLig ® 639 a to selectively remove perrhenate from high ionic strength simulated LAW. It is advantageous to operate at higher concentration in order to treat the waste stream without dilution and to minimize the volume of the final wasteform. This work examined the impact of high ionic strength, high density, and high viscosity if higher concentration LAW feed solution is used. Perrhenate (ReO 4 -) has been shown to be a good nonradioactive surrogate for pertechnetate in laboratory testing for this ion exchange resin, and the performance bias is well established. Equilibrium contact testing with 7.8 M [Na +] average simulant concentrations indicated that the SuperLig ® 639 resin average perrhenate distribution coefficient was 368 mL/g at a 100:1 phase ratio. Although this indicates good performance at high ionic strength, an equilibrium test cannot examine the impact of liquid viscosity, which impacts the diffusivity of ions and therefore the loading kinetics. To get an understanding of the effect of diffusivity, modeling was performed, which will be followed up with column tests in the future.« less
Pulmonary deposition and disappearance of aerosolised secretory leucocyte protease inhibitor.
Stolk, J.; Camps, J.; Feitsma, H. I.; Hermans, J.; Dijkman, J. H.; Pauwels, E. K.
1995-01-01
BACKGROUND--The neutrophil elastase inhibitor, secretory leucocyte protease inhibitor (SLPI), is a potential therapeutic tool in inflammatory lung diseases such as cystic fibrosis and pulmonary emphysema. The distribution and disappearance in the lung of aerosolised recombinant SLPI (rSLPI) was investigated in healthy humans and in patients with cystic fibrosis or alpha 1-antitrypsin-associated emphysema. METHODS--To distinguish aerosolised rSLPI from endogenous SLPI the recombinant inhibitor was radiolabelled with 99m-technetium (99mTc) pertechnetate. Distribution and disappearance of aerosolised 99mTc-rSLPI in the lungs were studied by gamma radiation imaging. RESULTS--The deposition of 99mTc-rSLPI in normal volunteers was homogeneous in all lung lobes, while in patients with cystic fibrosis or emphysema only well ventilated areas showed deposition of the aerosol. The disappearance rate of 99mTc-rSLPI was biexponential. The half life of the rapid phase was 0.2-2.8 hours, while that of the slow phase was more than 24 hours. CONCLUSIONS--Future aerosol therapy with rSLPI will be most beneficial for well ventilated lung tissue that needs protection against neutrophil derived elastase. It may be more difficult to neutralise the burden of elastase in poorly ventilated, highly inflamed areas as are seen in cystic fibrosis. Images PMID:7638807
Automation of ⁹⁹Tc extraction by LOV prior ICP-MS detection: application to environmental samples.
Rodríguez, Rogelio; Leal, Luz; Miranda, Silvia; Ferrer, Laura; Avivar, Jessica; García, Ariel; Cerdà, Víctor
2015-02-01
A new, fast, automated and inexpensive sample pre-treatment method for (99)Tc determination by inductively coupled plasma-mass spectrometry (ICP-MS) detection is presented. The miniaturized approach is based on a lab-on-valve (LOV) system, allowing automatic separation and preconcentration of (99)Tc. Selectivity is provided by the solid phase extraction system used (TEVA resin) which retains selectively pertechnetate ion in diluted nitric acid solution. The proposed system has some advantages such as minimization of sample handling, reduction of reagents volume, improvement of intermediate precision and sample throughput, offering a significant decrease of both time and cost per analysis in comparison to other flow techniques and batch methods. The proposed LOV system has been successfully applied to different samples of environmental interest (water and soil) with satisfactory recoveries, between 94% and 98%. The detection limit (LOD) of the developed method is 0.005 ng. The high durability of the resin and its low amount (32 mg), its good intermediate precision (RSD 3.8%) and repeatability (RSD 2%) and its high extraction frequency (up to 5 h(-1)) makes this method an inexpensive, high precision and fast tool for monitoring (99)Tc in environmental samples. Copyright © 2014 Elsevier B.V. All rights reserved.
Immobilization of 99-Technetium (VII) by Fe(II)-Goethite and Limited Reoxidation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Um, Wooyong; Chang, Hyun-Shik; Icenhower, Jonathan P.
2011-05-04
Synthesized goethite was successfully used with addition of Fe(II) to sequester Tc present in both deionized water and simulated off-gas scrubber waste solutions. Pertechnetate concentration in solution decreased immediately when the pH was raised above 7 by addition of sodium hydroxide. Removal of Tc(VII) from solution occurred most likely as a result of heterogeneous surface-catalyzed reduction to Tc(IV) and subsequent co-precipitation onto the goethite. The final Tc-bearing solid was identified as goethite-dominated Fe(III)-(oxy)hydroxide based on XRD analysis, confirming the widespread observation of its characteristic acicular habit by TEM/SEM images. Analysis of the solid precipitate by XAFS showed that the dominantmore » oxidation state of Tc was Tc(IV) and was in octahedral coordination with Tc-O, Fe-O, and Tc-Fe bond distances that are consistent with direct substitution of Tc for Fe in the goethite structure. In some experiments the final Tc-goethite product was subsequently armored with additional layers of freshly precipitated goethite. Successful incorporation of Tc(IV) within the goethite mineral lattice and subsequent goethite armoring can limit re-oxidation of Tc(IV) and its subsequent release from Tc-goethite waste forms, even when the final product is placed in oxidizing environments that typify shallow waste burial facilities.« less
Effects of epinephrine on lidocaine pharmacokinetics and blood volume in the dental pulp.
Hashimoto, Shuichi; Yamashiro, Mikiko; Fujita, Kyohei; Yasuda, Asako; Sunada, Katsuhisa
2014-09-01
Epinephrine potentiates and prolongs the efficacy of local anesthetics by reducing blood flow. We investigated the effect of epinephrine on the pharmacokinetics of lidocaine and the pulpal blood volume after maxillary infiltration anesthesia in rats. We measured the (14)C-radioactivity and (14)C-distribution in the maxilla and the dental pulp after the injection of 2% (14)C-lidocaine with or without 10 μg/mL epinephrine (n = 7) into the palatine mucosa proximal to the first molar. The blood volume in the pulp was measured using (99m)Tc-pertechnetate (n = 5). When lidocaine was injected together with epinephrine, the lidocaine became widely distributed throughout the maxilla and was observed mainly in the first molar pulp. The lidocaine amount in the dental pulp at 10-60 minutes was more than 2 times higher than that after the injection of lidocaine alone. The relative pulpal blood volume after 20 minutes decreased to 63.1% of the value after the injection of lidocaine alone. We found that lidocaine had infiltrated into the molar pulp after infiltration anesthesia. Furthermore, our results suggested that epinephrine augmented the retention of lidocaine in the pulp. Copyright © 2014 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Namey, T.C.; Rosenthall, L.
1976-01-01
The periarticular uptake of /sup 99m/technetium-labeled diphosphonate (/sup 99m/TcDP) was compared in 12 patients hospitalized for psoriasis and in 12 hospitalized for other dermatoses not associated with arthropathy. The 12 patients with psoriasis had recent onset disease of less than 5 years duration; neither group had historical or clinical evidence of arthritis. All psoriatics had markedly abnormal scans with symmetrically increased periarticular uptake about the imaged joints. None of the controls had similar findings. In 4 patients scanned with /sup 99m/technetium-pertechnetate within 24 hours of their /sup 99m/TcDP scan, no evidence of inflammatory synovitis was found. Three of these patientsmore » were serially imaged with /sup 99m/TcDP at intervals of 2 weeks to 3 months after their initial study, when obvious clinical improvement in their psoriasis was apparent. Improvement in the radionuclide joint images was demonstrated in some of the patients, but none reverted to normal during the study period. In light of recent evidence for the preferential binding of /sup 99m/TcDP to immature collagen, it is suggested that psoriasis may represent a generalized, but uncharacterized, collagen disorder present in bone as well as skin, linking the cutaneous disease with the potential for arthropathy.« less
Subclinical thyrotoxicosis in an outpatient population - predictors of outcome.
Schouten, Belinda J; Brownlie, Bevan E W; Frampton, Chris M; Turner, John G
2011-02-01
Individuals with endogenous subclinical thyrotoxicosis (SCT) may subsequently require treatment for overt disease. We aimed to evaluate the frequency of progression to hyperthyroidism and factors influencing this outcome. This is a retrospective analysis of outcome in 96 consecutive patients (aged 16-91 years) diagnosed with SCT over a 6-year period. Individuals with secondary causes of TSH suppression were excluded. Mean follow-up was 3·8 years. The significance of age, gender, family history of thyrotoxicosis, symptoms at presentation, thyroid nodule(s) on clinical examination, entry TSH level, antithyroid antibody status and (99m) Tc pertechnetate thyroid imaging results on subsequent development of overt thyrotoxicosis was assessed. Progression to overt thyrotoxicosis was seen in 8% at 1 year, 16% at 2 years, 21% at 3 years and 26% at 5 years. Multivariate analysis determined that diagnosis as determined by scintiscan to be the only independent predictor of outcome (P = 0·003) with the cumulative percentage requiring therapy at 5 years being 9% for subclinical Graves' disease, 21% for multinodular goitre and 61% for the autonomous nodule subgroup. Progression of SCT to overt hyperthyroidism occurred at a rate of 5-8% per year with disease aetiology, as determined by thyroid scintigraphy, significantly influencing risk of progression. © 2011 Blackwell Publishing Ltd.
Oliver, D W; Balan, K K; Burrows, N P; Hall, P N
2000-06-01
Ehlers-Danlos syndrome (EDS) is the commonest inherited disorder of connective tissue, affecting around 10 000 patients in the UK. Patients with EDS have reported that local anaesthetic is often ineffective. Patients with less severe skin laxity often have the most problems. We have postulated that this resistance to local anaesthetics is not due to the lax connective tissues as is often assumed. This study used radioactively labelled solution ((99m)Tc-pertechnetate) administered as a deep dermal injection in the forearm. The rate of dispersal of isotope was measured over 60 min and found to be identical between six patients with EDS and three controls. The effects of local anaesthetics are complex and depend on the individual chemical properties of the agent and a number of tissue factors. This study would suggest that the lack of effectiveness of local anaesthetic solutions is not due to rapid dispersal of solution. It is unlikely therefore that its lack of effect can be compensated for by simply increasing the amount used. The diagnosis of EDS should be considered in any patient who complains unexpectedly of pain during their procedure, particularly when the surgeon knows that an adequate volume of local anaesthetic has been used. Copyright 2000 The British Association of Plastic Surgeons.
SPECT/CT analysis of splenic function in genistein-treated malaria-infected mice.
Ha, Young Ran; Kang, Sung-A; Ryu, Jeongeun; Yeom, Eunseop; Kim, Mun Ki; Lee, Sang Joon
2016-11-01
Spleen traps malaria-infected red blood cells, thereby leading to splenomegaly. Splenomegaly induces impairment in splenic function, i.e., rupture. Therefore, splenomegaly inhibition is required to protect the spleen. In our previous study, genistein was found to have an influence on malaria-induced splenomegaly. However, the effect of genistein in malaria-induced splenomegaly, especially on the function of spleen, has not been fully investigated. In this study, hematoxylin and eosin (H&E) staining images show that genistein partially prevents malaria-induced architectural disruption of spleen. In addition, genistein decreases transgenic Plasmodium parasites accumulation in the spleen. Genistein treatment can protect splenic function from impairment caused by malaria infection. To examine the functions of malaria-infected spleen, we employed single-photon emission computed tomography/computed tomography (SPECT/CT) technology. Red blood cells are specifically radiolabeled with Technetium-99m pertechnetate ( 99m TcO 4 - ) and trapped inside the spleen. The standardized uptake values (SUVs) in the spleen of infected mice are higher than those of naive and genistein-treated mice. However, genistein reduces the malaria-induced trapping capacity of spleen for heat-damaged radiolabeled RBCs, while exhibiting a protective effect against malaria. Considering these results, we suggested that genistein could be effectively used in combination therapy for malaria-induced splenic impairment. Copyright © 2016 Elsevier Inc. All rights reserved.
Development of Alternative Technetium Waste Forms
DOE Office of Scientific and Technical Information (OSTI.GOV)
Czerwinski, Kenneth
2013-09-13
The UREX+1 process is under consideration for the separation of transuranic elements from spent nuclear fuel. The first steps of this process extract the fission product technicium-99 ({sup 99}Tc) into an organic phase containing tributylphosphate together with uranium. Treatment of this stream requires the separation of Tc from U and placement into a suitable waste storage form. A potential candidate waste form involves immobilizing the Tc as an alloy with either excess metallic zirconium or stainless steel. Although Tc-Zr alloys seem to be promising waste forms, alternative materials must be investigated. Innovative studies related to the synthesis and behavior ofmore » a different class of Tc materials will increase the scientific knowledge related to development of Tc waste forms. These studies will also provide a better understanding of the behavior of {sup 99}Tc in repository conditions. A literature survey has selected promising alternative waste forms for further study: technetium metallic alloys, nitrides, oxides, sulfides, and pertechnetate salts. The goals of this project are to 1) synthesize and structurally characterize relevant technetium materials that may be considered as waste forms, 2) investigate material behavior in solution under different conditions of temperature, electrochemical potential, and radiation, and 3) predict the long-term behavior of these materials.« less
(99)Tc(VII) Retardation, Reduction, and Redox Rate Scaling in Naturally Reduced Sediments.
Liu, Yuanyuan; Liu, Chongxuan; Kukkadapu, Ravi K; McKinley, James P; Zachara, John; Plymale, Andrew E; Miller, Micah D; Varga, Tamas; Resch, Charles T
2015-11-17
An experimental and modeling study was conducted to investigate pertechnetate (Tc(VII)O4(-)) retardation, reduction, and rate scaling in three sediments from Ringold formation at U.S. Department of Energy's Hanford site, where (99)Tc is a major contaminant in groundwater. Tc(VII) was reduced in all the sediments in both batch reactors and diffusion columns, with a faster rate in a sediment containing a higher concentration of HCl-extractable Fe(II). Tc(VII) migration in the diffusion columns was reductively retarded with retardation degrees correlated with Tc(VII) reduction rates. The reduction rates were faster in the diffusion columns than those in the batch reactors, apparently influenced by the spatial distribution of redox-reactive minerals along transport paths that supplied Tc(VII). X-ray computed tomography and autoradiography were performed to identify the spatial locations of Tc(VII) reduction and transport paths in the sediments, and results generally confirmed the newly found behavior of reaction rate changes from batch to column. The results from this study implied that Tc(VII) migration can be reductively retarded at Hanford site with a retardation degree dependent on reactive Fe(II) content and its distribution in sediments. This study also demonstrated that an effective reaction rate may be faster in transport systems than that in well-mixed reactors.
High incidence of vesicoureteric reflux in asymptomatic siblings of children with known reflux
DOE Office of Scientific and Technical Information (OSTI.GOV)
Treves, S.T.; Van den Abbeele, A.D.; Davis, R.T.
1985-05-01
A significant occurrence of vesicoureteric reflux in siblings of children with reflux has been previously suggested. The purpose of this study was to evaluate the incidence of vesicoureteric reflux in asymptomatic siblings of children with vesicoureteric reflux using radionuclide voiding cystography (RNC). A random group of 52 siblings was studied. Their ages were from 2 mos. to 13 yrs. (mean 4 yrs.). Seventy-one percent were female and 29% male, RNC was performed with the patients supine, and Tc-99m pertechnetate (2mCi/1) was infused into the bladder by catheter. A computerized gamma camera recorded the filling and voiding phase of the studymore » at 1 frame/5 sec. Reflux was detected in 40% of the patients. It was bilateral in 17% and unilateral in 23% of the patients. Reflux was identified to the renal pelves in half of the patients. In two of these patients Tc-99m DMSA scans were obtained which revealed significant renal scarring. This study demonstrates the high incidence of reflux of various degrees in these asymptomatic siblings on high risk of developing significant renal disease. Identification and proper treatment of asymptomatic children with vesicoureteric reflux may help prevent the development of renal damage.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Taylor, T.A.; Short, R.J.; Gribble, N.R.
2013-07-01
The Waste Vitrification Plant (WVP) converts Highly Active Liquor (HAL) from spent nuclear fuel reprocessing into a stable vitrified product. Recently WVP have been experiencing accumulation of solids in their primary off gas (POG) system leading to potential blockages. Chemical analysis of the blockage material via Laser Induced Breakdown Spectroscopy (LIBS) has shown it to exclusively consist of caesium, technetium and oxygen. The solids are understood to be caesium pertechnetate (CsTcO{sub 4}), resulting from the volatilisation of caesium and technetium from the high level waste glass melt. Using rhenium as a chemical surrogate for technetium, a series of full scalemore » experiments have been performed in order to understand the mechanism of rhenium volatilisation as caesium perrhenate (CsReO{sub 4}), and therefore technetium volatilisation as CsTcO{sub 4}. These experiments explored the factors governing volatilisation rates from the melt, potential methods of minimising the amount of volatilisation, and various strategies for mitigating the deleterious effects of the volatile material on the POG. This paper presents the results from those experiments, and discusses potential methods to minimise blockages that can be implemented on WVP, so that the frequency of the CsTcO{sub 4} blockages can be reduced or even eradicated altogether. (authors)« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lee, Ji-Hoon; Fredrickson, James K.; Plymale, Andrew E.
2015-04-08
Increasing concentrations of H 2 with depth were observed across a geologic unconformity and associated redox transition zone in the subsurface at the Hanford Site in south-central Washington, USA. An opposing gradient characterized by decreasing O 2 and nitrate concentrations was consistent with microbial-catalyzed biogeochemical processes. Sterile sand was incubated in situ within a multi-level sampler placed across the redox transition zone to evaluate the potential for Tc(VII) reduction and for enrichment of H 2-oxidizing denitrifiers capable of reducing Tc(VII). H 2-driven TcO 4- reduction was detected in sand incubated at all depths but was strongest in material from amore » depth of 17.1 m. Acidovorax spp. were isolated from H 2-nitrate enrichments from colonized sand from 15.1 m, with one representative, strain JHL-9, subsequently characterized. JHL-9 grew on acetate with either O 2 or nitrate as electron acceptor (data not shown) and on medium with bicarbonate, H 2 and nitrate. JHL-9 also reduced pertechnetate (TcO 4-) under denitrifying conditions with H 2 as the electron donor. H 2-oxidizing Acidovorax spp. in the subsurface at Hanford and other locations may contribute to the maintenance of subsurface redox gradients and offer the potential for Tc(VII) reduction.« less
A new hypothesis for fluidification of vocal-fold mucus: scintigraphic study.
Costa, Milton Melciades Barbosa; Maliska, Carmelindo
2012-05-01
Our aim was to establish a new hypothesis for the fluidification of the mucus of the vocal folds, by using a scintigraphic method to analyze the relationship of the saliva from the oral and pharyngeal cavities to the mucosa of the laryngeal vestibule. We theorized that the saliva that is adsorbed on the oral and pharyngeal mucosa enters the larynx and is also adsorbed on its mucosa, as a natural layer, fluidizing the mucus of the vestibule wall. A saline solution of sodium pertechnetate (Na(99m)TcO(4)) with radioactivity of 1.0 mCi was sprayed in the oral cavity of seven healthy volunteers, who were instructed to chew a piece of apple for as long as possible without swallowing. The migration of the radioactive saliva was recorded by a gamma-chamber apparatus. We observed radioactivity in the laryngeal mucosa in six of the seven volunteers, who developed no complaints and no respiratory-defense reactions. The results for frequency were statistically significant (Mann-Whitney test, P=0.05). The results indicate that an increased volume of saliva enters the larynx and is adsorbed in its mucosa, producing mucus fluidification. This supports our alternative hypothesis to the unlikely concept that hydration by water ingestion is the factor responsible for reduction of the mucus viscosity of the vocal folds. Copyright © 2012 The Voice Foundation. Published by Mosby, Inc. All rights reserved.
Dual ectopic thyroid associated with thyroid hemiagenesis.
Nakamura, Shigenori; Masuda, Teruyuki; Ishimori, Masatoshi
2018-01-01
We report a case of a 15-year-old girl with a midline neck mass that was first noted 2 or 3 years previously. She had been treated with levothyroxine (L-T4) for congenital hypothyroidism until 11 years of age. Ultrasonography revealed an atrophic right thyroid (1.0 × 1.6 × 2.6 cm in size) and a mass (2.3 × 1.0 × 3.5 cm in size) in the upper part of the neck. No left lobe of the thyroid was detected. On further evaluation, Tc-99m pertechnetate thyroid scintigraphy and CT showed ectopic thyroid tissue in the lingual region and infrahyoid region. Thus, she was diagnosed as having dual ectopic thyroid and thyroid hemiagenesis. The atrophic right thyroid was thought be non-functional. Treatment with L-T4 was started to reduce the size of the dual ectopic thyroid tissue. This may be the first reported case of dual ectopic thyroid associated with hemiagenesis detected only by ultrasonography. Ultrasonography can confirm the presence or absence of orthotopic thyroid tissue in patients with ectopic thyroid.The cause of congenital hypothyroidism should be examined.Clinical manifestation of ectopic thyroid may appear when the treatment with L-T4 is discontinued.Annual follow-up is needed in all children when their thyroid hormone replacement is stopped.
Ferrandino, Giuseppe; Kaspari, Rachel R; Reyna-Neyra, Andrea; Boutagy, Nabil E; Sinusas, Albert J; Carrasco, Nancy
2017-07-13
The sodium/iodide symporter (NIS) mediates active iodide (I - ) accumulation in the thyroid, the first step in thyroid hormone (TH) biosynthesis. Mutations in the SLC5A5 gene encoding NIS that result in a non-functional protein lead to congenital hypothyroidism due to I - transport defect (ITD). ITD is a rare autosomal disorder that, if not treated promptly in infancy, can cause mental retardation, as the TH decrease results in improper development of the nervous system. However, in some patients, hypothyroidism has been ameliorated by unusually large amounts of dietary I - . Here we report the first NIS knockout (KO) mouse model, obtained by targeting exons 6 and 7 of the Slc5a5 gene. In NIS KO mice, in the thyroid, stomach, and salivary gland, NIS is absent, and hence there is no active accumulation of the NIS substrate pertechnetate ( 99m TcO 4 - ). NIS KO mice showed undetectable serum T 4 and very low serum T 3 levels when fed a diet supplying the minimum I - requirement for rodents. These hypothyroid mice displayed oxidative stress in the thyroid, but not in the brown adipose tissue or liver. Feeding the mice a high-I - diet partially rescued TH biosynthesis, demonstrating that, at high I - concentrations, I - enters the thyroid through routes other than NIS.
Sharma, Braj Gaurav; Khanna, Kushagra; Kumar, Neeraj; Nishad, Dhruv K; Basu, Mitra; Bhatnagar, Aseem
2017-11-01
Calcium chloride is an essential calcium channel agonist which plays an important role in the contraction of muscles by triggering calcium channel. First time hypothesized about its role in the treatment of GER (gastro-esophageal reflux) and vomiting disorder due to its local action. There are two objectives covered in this study as first, the development and optimization of floating formulation of calcium chloride and another objective was to evaluate optimized formulation through gamma scintigraphy in human subjects. Gastro retentive formulation of calcium chloride was prepared by direct compression method. Thirteen tablet formulations were designed with the help of sodium chloride, HPMC-K4M, and carbopol-934 along with effervescing agent sodium bicarbonate and citric acid. Formulation (F8) fitted best for Korsmeyer-Peppas equation with an R 2 value of 0.993. The optimized formulation was radiolabelled with 99m Tc-99 m pertechnetate for its evaluation by gamma scintigraphy. Gastric retention (6 h) was evaluated by gamma scintigraphy in healthy human subjects and efficacy of present formulation confirmed in GER positive human subjects. Gamma scintigraphy results indicated its usefulness in order to manage GERD. Stability studies of the developed formulation were carried out as per ICH guidelines for region IV and found out to be stable for 24 months.
Evaluation of salivary function in patients with burning mouth syndrome.
Lee, Y C; Hong, I K; Na, S Y; Eun, Y G
2015-04-01
To investigate salivary function in patients with primary burning mouth syndrome (BMS) compared with control and to evaluate salivary hypofunction using salivary gland scintigraphy (SGS). A total of 33 patients with primary BMS and 30 control subjects were enrolled in our study. The severity of the pain and the burning sensation on a 10-cm visual analog scale (VAS) and the Oral Health Impact Profile-14 (OHIP-14) were assessed. Unstimulated and stimulated salivary flow rates (SFRs) were measured. (99m) Tc pertechnetate SGS was used to evaluate salivary gland function. Unstimulated SFR in patients with BMS was significantly lower than that in the control group (0.11 ± 0.15 vs 0.21 ± 0.16 ml min(-1) , P = 0.014). There was no significant difference in stimulated SFR between the two groups. The VAS scores for oral pain and burning sensation, the total OHIP-14 score, and salivary gland function by salivary scintigraphy were not significantly different between BMS patients with normal flow rate and hyposalivation. Patients with primary BMS exhibited a significant decrease in unstimulated SFR compared with control group. In addition, we could not find any difference in salivary gland function between BMS patients with or without hyposalivation. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Residence time effects on technetium reduction in slag-based cementitious materials.
Arai, Yuji; Powell, Brian A; Kaplan, D I
2018-01-15
A long-term disposal of technetium-99 ( 99 Tc) has been considered in a type of cementitious formulation, slag-based grout, at the U.S. Department of Energy, Savannah River Site, Aiken SC, U.S.A. Blast furnace slag, which contains S and Fe electron donors, has been used in a mixture with fly ash, and Portland cement to immobilize 99 Tc(VII)O 4 - (aq) in low level radioactive waste via reductive precipitation reaction. However the long-term stability of Tc(IV) species is not clearly understood as oxygen gradually diffuses into the solid structure. In this study, aging effects of Tc speciation were investigated as a function of depth (<2.5cm) in slag-based grout using X-ray absorption spectroscopy. All of Fe(II) in solids was oxidized to Fe(III) after 117d. However, elemental S, sulfide, and sulfoxide persists at the 0-8mm depths even after 485d, suggesting the presence of a reduced zone below the surface few millimeters. Pertechnetate was successfully reduced to Tc(IV) after 29d. Distorted hydrolyzed Tc(IV) octahedral molecules were partially sulfidized and or polymerized at all depths (0-8mm) and were stable in 485d aged sample. The results of this study suggest that variable S species contribute to stabilize the partially sulfidized Tc(IV) species in aged slag-based grout. Copyright © 2017 Elsevier B.V. All rights reserved.
The function of Sn(II)-apatite as a Tc immobilizing agent
DOE Office of Scientific and Technical Information (OSTI.GOV)
Asmussen, R. Matthew; Neeway, James J.; Lawter, Amanda R.
2016-11-01
Technetium-99 is a radioactive contaminant of high concern at many nuclear waste storage sites. At the U.S. Department of Energy Hanford Site, 99Tc is a component of low-activity waste (LAW) fractions of the nuclear tank waste, which are highly caustic, high ionic strength and have high concentrations of chromate. Removal of 99Tc from LAW streams would greatly benefit the site remediation process. In this study, we investigated the removal of 99Tc(VII), as pertechnetate, from deionized water (DIW) and a LAW simulant using two solid sorbents, tin (II) apatite (Sn-A) and SnCl2 through batch sorption testing and solid phase characterization. Sn-Amore » showed higher levels of removal of Tc from both DIW and LAW simulant compared with the SnCl2. Scanning electron microscopy/energy dispersive X-ray spectroscopy (SEM/XEDS) and X-ray adsorption spectroscopy (XAS) of Sn-A following batch experiments in DIW showed that TcO4- is reduced to Tc(IV) on the Sn-A surface with no incorporation into the lattice structure of Sn-A. The performance of Sn-A in the LAW simulant was lowered due to a combined effect of the high alkalinity, which lead to an increased dissolution of Sn from the Sn-A, and a preference for the reduction of Cr(VI) over Tc(VII).« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lukens, Wayne W.; Saslow, Sarah A.
Technetium-99 (Tc) is a problematic fission product that complicates the long-term disposal of nuclear waste due to its long half-life, high fission yield, and the environmental mobility of pertechnetate, its stable form in aerobic environments. One approach to preventing Tc contamination is through incorporation into durable waste forms based on weathering-resistant minerals such as rutile (titanium dioxide). Here, the incorporation of technetium into titanium dioxide by means of simple, aqueous chemistry is presented. X-ray absorption fine structure spectroscopy and diffuse reflectance spectroscopy indicate that Tc(IV) replaces Ti(IV) within the structure. Rather than being incorporated as isolated Tc(IV) ions, Tc ismore » present as pairs of edge-sharing Tc(IV) octahedra similar to molecular Tc(IV) complexes such as [(H2EDTA)TcIV](u-O)2. Technetium-doped TiO2 was suspended in deionized water under aerobic conditions, and the Tc leached under these conditions was followed for 8 months. The normalized release rate of Tc (LRTc) from the TiO2 particles is low (3×10-6 g m-2 d-1), which illustrates the potential utility of TiO2 as waste form. However, the small size of the as-prepared TiO2 nanoparticles results in estimated retention of Tc for 104 years, which is only a fraction of the half-life of Tc (2×10-5 years).« less
Effect Of Oxidation On Chromium Leaching And Redox Capacity Of Slag-Containing Waste Forms
DOE Office of Scientific and Technical Information (OSTI.GOV)
Almond, P. M.; Stefanko, D. B.; Langton, C. A.
2013-03-01
The rate of oxidation is important to the long-term performance of reducing salt waste forms because the solubility of some contaminants, e.g., technetium, is a function of oxidation state. TcO 4 - in the salt solution is reduced to Tc(IV) and has been shown to react with ingredients in the waste form to precipitate low solubility sulfide and/or oxide phases [Shuh, et al., 1994, Shuh, et al., 2000, Shuh, et al., 2003]. Upon exposure to oxygen, the compounds containing Tc(IV) oxidize to the pertechnetate ion, Tc(VII)O 4 -, which is very soluble. Consequently the rate of technetium oxidation front advancementmore » into a monolith and the technetium leaching profile as a function of depth from an exposed surface are important to waste form performance and ground water concentration predictions. An approach for measuring contaminant oxidation rate (effective contaminant specific oxidation rate) based on leaching of select contaminants of concern is described in this report. In addition, the relationship between reduction capacity and contaminant oxidation is addressed. Chromate was used as a non-radioactive surrogate for pertechnetate in simulated waste form samples. Depth discrete subsamples were cut from material exposed to Savannah River Site (SRS) field cured conditions. The subsamples were prepared and analyzed for both reduction capacity and chromium leachability. Results from field-cured samples indicate that the depth at which leachable chromium was detected advanced further into the sample exposed for 302 days compared to the sample exposed to air for 118 days (at least 50 mm compared to at least 20 mm). Data for only two exposure time intervals is currently available. Data for additional exposure times are required to develop an equation for the oxidation front progression. Reduction capacity measurements (per the Angus-Glasser method, which is a measurement of the ability of a material to chemically reduce Ce(IV) to Ce(III) in solution) performed on depth discrete samples could not be correlated with the amount of chromium leached from the depth discrete subsamples or with the oxidation front inferred from soluble chromium (i.e., effective Cr oxidation front). Exposure to oxygen (air or oxygen dissolved in water) results in the release of chromium through oxidation of Cr(III) to highly soluble chromate, Cr(VI). Residual reduction capacity in the oxidized region of the test samples indicates that the remaining reduction capacity is not effective in re-reducing Cr(VI) in the presence of oxygen. Consequently, this method for determining reduction capacity may not be a good indicator of the effective contaminant oxidation rate in a relatively porous solid (40 to 60 volume percent porosity). The chromium extracted in depth discrete samples ranged from a maximum of about 5.8 % at about 5 mm (118 day exposure) to about 4 % at about 10 mm (302 day exposure). The use of reduction capacity as an indicator of long-term performance requires further investigation. The carbonation front was also estimated to have advanced to at least 28 mm in 302 days based on visual observation of gas evolution during acid addition during the reduction capacity measurements. Depth discrete sampling of materials exposed to realistic conditions in combination with short term leaching of crushed samples has potential for advancing the understanding of factors influencing performance and will support conceptual model development.« less
Goethite Bench-scale and Large-scale Preparation Tests
DOE Office of Scientific and Technical Information (OSTI.GOV)
Josephson, Gary B.; Westsik, Joseph H.
2011-10-23
The Hanford Waste Treatment and Immobilization Plant (WTP) is the keystone for cleanup of high-level radioactive waste from our nation's nuclear defense program. The WTP will process high-level waste from the Hanford tanks and produce immobilized high-level waste glass for disposal at a national repository, low activity waste (LAW) glass, and liquid effluent from the vitrification off-gas scrubbers. The liquid effluent will be stabilized into a secondary waste form (e.g. grout-like material) and disposed on the Hanford site in the Integrated Disposal Facility (IDF) along with the low-activity waste glass. The major long-term environmental impact at Hanford results from technetiummore » that volatilizes from the WTP melters and finally resides in the secondary waste. Laboratory studies have indicated that pertechnetate ({sup 99}TcO{sub 4}{sup -}) can be reduced and captured into a solid solution of {alpha}-FeOOH, goethite (Um 2010). Goethite is a stable mineral and can significantly retard the release of technetium to the environment from the IDF. The laboratory studies were conducted using reaction times of many days, which is typical of environmental subsurface reactions that were the genesis of this new process. This study was the first step in considering adaptation of the slow laboratory steps to a larger-scale and faster process that could be conducted either within the WTP or within the effluent treatment facility (ETF). Two levels of scale-up tests were conducted (25x and 400x). The largest scale-up produced slurries of Fe-rich precipitates that contained rhenium as a nonradioactive surrogate for {sup 99}Tc. The slurries were used in melter tests at Vitreous State Laboratory (VSL) to determine whether captured rhenium was less volatile in the vitrification process than rhenium in an unmodified feed. A critical step in the technetium immobilization process is to chemically reduce Tc(VII) in the pertechnetate (TcO{sub 4}{sup -}) to Tc(Iv)by reaction with the ferrous ion, Fe{sup 2+}-Fe{sup 2+} is oxidized to Fe{sup 3+} - in the presence of goethite seed particles. Rhenium does not mimic that process; it is not a strong enough reducing agent to duplicate the TcO{sub 4}{sup -}/Fe{sup 2+} redox reactions. Laboratory tests conducted in parallel with these scaled tests identified modifications to the liquid chemistry necessary to reduce ReO{sub 4}{sup -} and capture rhenium in the solids at levels similar to those achieved by Um (2010) for inclusion of Tc into goethite. By implementing these changes, Re was incorporated into Fe-rich solids for testing at VSL. The changes also changed the phase of iron that was in the slurry product: rather than forming goethite ({alpha}-FeOOH), the process produced magnetite (Fe{sub 3}O{sub 4}). Magnetite was considered by Pacific Northwest National Laboratory (PNNL) and VSL to probably be a better product to improve Re retention in the melter because it decomposes at a higher temperature than goethite (1538 C vs. 136 C). The feasibility tests at VSL were conducted using Re-rich magnetite. The tests did not indicate an improved retention of Re in the glass during vitrification, but they did indicate an improved melting rate (+60%), which could have significant impact on HLW processing. It is still to be shown whether the Re is a solid solution in the magnetite as {sup 99}Tc was determined to be in goethite.« less
Cast Stone Oxidation Front Evaluation: Preliminary Results For Samples Exposed To Moist Air
DOE Office of Scientific and Technical Information (OSTI.GOV)
Langton, C. A.; Almond, P. M.
The rate of oxidation is important to the long-term performance of reducing salt waste forms because the solubility of some contaminants, e.g., technetium, is a function of oxidation state. TcO{sub 4}{sup -} in the salt solution is reduced to Tc(IV) and has been shown to react with ingredients in the waste form to precipitate low solubility sulfide and/or oxide phases. Upon exposure to oxygen, the compounds containing Tc(IV) oxidize to the pertechnetate ion, Tc(VII)O{sub 4}{sup -}, which is very soluble. Consequently the rate of technetium oxidation front advancement into a monolith and the technetium leaching profile as a function ofmore » depth from an exposed surface are important to waste form performance and ground water concentration predictions. An approach for measuring contaminant oxidation rate (effective contaminant specific oxidation rate) based on leaching of select contaminants of concern is described in this report. In addition, the relationship between reduction capacity and contaminant oxidation is addressed. Chromate (Cr(VI) was used as a non-radioactive surrogate for pertechnetate, Tc(VII), in Cast Stone samples prepared with 5 M Simulant. Cast Stone spiked with pertechnetate was also prepared and tested. Depth discrete subsamples spiked with Cr were cut from Cast Stone exposed to Savannah River Site (SRS) outdoor ambient temperature fluctuations and moist air. Depth discrete subsamples spiked with Tc-99 were cut from Cast Stone exposed to laboratory ambient temperature fluctuations and moist air. Similar conditions are expected to be encountered in the Cast Stone curing container. The leachability of Cr and Tc-99 and the reduction capacities, measured by the Angus-Glasser method, were determined for each subsample as a function of depth from the exposed surface. The results obtained to date were focused on continued method development and are preliminary and apply to the sample composition and curing / exposure conditions described in this report. The Cr oxidation front (depth to which soluble Cr was detected) for the Cast Stone sample exposed for 68 days to ambient outdoor temperatures and humid air (total age of sample was 131 days) was determined to be about 35 mm below the top sample surface exposed. The Tc oxidation front, depth at which Tc was insoluble, was not determined. Interpretation of the results indicates that the oxidation front is at least 38 mm below the exposed surface. The sample used for this measurement was exposed to ambient laboratory conditions and humid air for 50 days. The total age of the sample was 98 days. Technetium appears to be more easily oxidized than Cr in the Cast Stone matrix. The oxidized forms of Tc and Cr are soluble and therefore leachable. Longer exposure times are required for both the Cr and Tc spiked samples to better interpret the rate of oxidation. Tc spiked subsamples need to be taken further from the exposed surface to better define and interpret the leachable Tc profile. Finally Tc(VII) reduction to Tc(IV) appears to occur relatively fast. Results demonstrated that about 95 percent of the Tc(VII) was reduced to Tc(IV) during the setting and very early stage setting for a Cast Stone sample cured 10 days. Additional testing at longer curing times is required to determine whether additional time is required to reduce 100 % of the Tc(VII) in Cast Stone or whether the Tc loading exceeded the ability of the waste form to reduce 100 % of the Tc(VII). Additional testing is required for samples cured for longer times. Depth discrete subsampling in a nitrogen glove box is also required to determine whether the 5 percent Tc extracted from the subsamples was the result of the sampling process which took place in air. Reduction capacity measurements (per the Angus-Glasser method) performed on depth discrete samples could not be correlated with the amount of chromium or technetium leached from the depth discrete subsamples or with the oxidation front inferred from soluble chromium and technetium (i.e., effective Cr and Tc oxidation fronts). Residual reduction capacity in the oxidized region of the test samples indicates that the remaining reduction capacity is not effective in re-reducing Cr(VI) or Tc(VII) in the presence of oxygen. Depth discrete sampling and leaching is a useful for evaluating Cast Stone and other chemically reducing waste forms containing ground granulated blast furnace slag (GGBFS) or other reduction / sequestration reagents to control redox sensitive contaminant chemistry and leachability in the near surface disposal environment. Based on results presented in this report, reduction capacity measured by the Angus-Glasser Ce(IV) method is not an appropriate or meaningful parameter for determining or predicting Tc and Cr oxidation / retentions, speciation, or solubilities in cementitious materials such as Cast Stone. A model for predicting Tc(IV) oxidation to soluble Tc(VII) should consider the waste form porosity (pathway for oxygen ingress), oxygen source, and the contaminant specific oxidation rates and oxidation fronts. Depth discrete sampling of materials exposed to realistic conditions in combination with short term leaching of crushed samples has potential for advancing the understanding of factors influencing performance. This information can be used to support conceptual model development.« less
Souza, Deise Elizabeth; Pereira, Marcia Oliveira; Bernardo, Luciana Camargo; Carmo, Fernanda Santos; Fonseca, Adenilson de Souza da; Bernardo-Filho, Mario
2011-01-01
Cassia angustifolia Vahl (senna) is a natural product that contains sennosides, which are active components that affect the intestinal tract and induce diarrhea. Authors have shown that senna produces DNA (deoxyribonucleic acid) lesions in Escherichia coli cultures and can act as an antifungal agent. Natural drugs can alter the labeling of blood constituents with technetium-⁹⁹m (⁹⁹mTc) and can affect the biodistribution of radiopharmaceuticals. In this work, we have evaluated the influence of a senna extract on the radiolabeling of blood constituents and on the biodistribution of the radiopharmaceutical sodium pertechnetate (Na⁹⁹mTcO₄)in Wistar rats. Twelve animals were treated with senna extract for 7 days. Blood samples were withdrawn from the animals and the radiolabeling procedure was carried out. The senna extract did not modify the radiolabeling of the blood constituents. A biodistributional assay was performed by administering Na⁹⁹mTcO₄ and determining its activity in different organs and in blood. The senna extract altered the biodistribution of Na⁹⁹mTcO₄ in the thyroid, liver, pancreas, lungs and blood. These results are associated with properties of the chemical substances present in the aqueous senna extract. Although these assays were performed in animals, our findings suggest that caution should be exercised when nuclear medicine examinations using Na⁹⁹mTcO₄ are conducted in patients who are using senna extract.
Souza, Deise Elizabeth; Pereira, Marcia Oliveira; Bernardo, Luciana Camargo; Carmo, Fernanda Santos; de Souza da Fonseca, Adenilson; Bernardo-Filho, Mario
2011-01-01
ABSTRACT Cassia angustifolia Vahl (senna) is a natural product that contains sennosides, which are active components that affect the intestinal tract and induce diarrhea. Authors have shown that senna produces DNA (deoxyribonucleic acid) lesions in Escherichia coli cultures and can act as an antifungal agent. Natural drugs can alter the labeling of blood constituents with technetium-99m (99mTc) and can affect the biodistribution of radiopharmaceuticals. In this work, we have evaluated the influence of a senna extract on the radiolabeling of blood constituents and on the biodistribution of the radiopharmaceutical sodium pertechnetate (Na99mTcO4) in Wistar rats. Twelve animals were treated with senna extract for 7 days. Blood samples were withdrawn from the animals and the radiolabeling procedure was carried out. The senna extract did not modify the radiolabeling of the blood constituents. A biodistributional assay was performed by administering Na99mTcO4 and determining its activity in different organs and in blood. The senna extract altered the biodistribution of Na99mTcO4 in the thyroid, liver, pancreas, lungs and blood. These results are associated with properties of the chemical substances present in the aqueous senna extract. Although these assays were performed in animals, our findings suggest that caution should be exercised when nuclear medicine examinations using Na99mTcO4 are conducted in patients who are using senna extract. PMID:21552677
Direct Imaging of Radionuclide-Produced Electrons and Positrons with an Ultrathin Phosphor
Chen, Liying; Gobar, Lisa S.; Knowles, Negar G.; Liu, Zhonglin; Gmitro, Arthur F.; Barrett, Harrison H.
2008-01-01
Current electron detectors are either unable to image in vivo or lack sufficient spatial resolution because of electron scattering in thick detector materials. This study was aimed at developing a sensitive high-resolution system capable of detecting electron-emitting isotopes in vivo. Methods The system uses a lens-coupled charge-coupled-device camera to capture the scintillation light excited by an electron-emitting object near an ultrathin phosphor. The spatial resolution and sensitivity of the system were measured with a 3.7-kBq 90Y/90Sr β-source and a 70-µm resin bead labeled with 99mTc. Finally, we imaged the 99mTc-pertechnetate concentration in the mandibular gland of a mouse in vivo. Results Useful images were obtained with only a few hundred emitted β particles from the 90Y/90Sr source or conversion electrons from the 99mTc bead source. The in vivo image showed a clear profile of the mandibular gland and many fine details with exposures of as low as 30 s. All measurements were consistent with a spatial resolution of about 50 µm, corresponding to 2.5 detector pixels with the current camera. Conclusion Our new electron-imaging system can image electron-emitting isotope distributions at high resolution and sensitivity. The system is useful for in vivo imaging of small animals and small, exposed regions on humans. The ability to image β particles, positrons, and conversion electrons makes the system applicable to most isotopes. PMID:18552136
Taniyama, Matsuo; Otsuka, Fumiko; Tozaki, Teruaki; Ban, Yoshiyuki
2013-07-01
Thyrotoxic disease can be difficult to recognize in patients with resistance to thyroid hormone (RTH) because the clinical symptoms of thyrotoxicosis cannot be observed, and thyrotropin (TSH) may not be suppressed because of hormone resistance. Painless thyroiditis is a relatively common cause of thyrotoxicosis, but its occurrence in RTH has not been reported. We assessed the thyroid profile in a patient with RTH and episodes of thyrotoxicosis who experienced repeated painless thyroiditis. A 44-year-old Japanese woman with RTH, which was confirmed by the presence of a P453A mutation in the thyroid hormone receptor β (TRβ) gene, showed a slight elevation of the basal levels of thyroid hormones, which indicated that her pituitary RTH was mild. She experienced a slight exacerbation of hyperthyroxinemia concomitant with TSH suppression. A diagnosis of painless thyroiditis was made because of the absence of TSH receptor antibodies, low Tc-99m pertechnetate uptake by the thyroid gland, and transient suppression followed by a slight elevation of TSH following the elevation of thyroid hormones. The patient's complaints of general malaise and occasional palpitations did not change throughout the course of painless thyroiditis. Three years later, painless thyroiditis occurred again without any deterioration of the clinical manifestations. Mild pituitary RTH can be overcome by slight exacerbation of hyperthyroxinemia during mild thyrotoxicosis. When pituitary resistance is severe and TSH is not suppressed, thyrotoxicosis may be overlooked.
Oliveira, J. F.; Braga, A. C.; Avila, A. S.; Fonseca, L. M.; Gutfilen, B.; Bernardo-Filho, M.
1996-01-01
Thuya occidentalis is used in popular medicine in the treatment of condyloma and has antibacterial action. Red blood cells (RBC) labeled with technetium-99m (99mTc) are used for several evaluations in nuclear medicine. This labeling depends on a reducing agent, usually stannous ion. Any drug which alters the labeling of the tracer could be expected to modify the disposition of the radiopharmaceutical. We have evaluated the influence of T. occidentalis extract on the labeling of RBC and plasma proteins with 99mTc. Blood was withdrawn and incubated with T. occidentalis (0.25; 2.5; 20.5; and 34.1 percent v/v). Stannous chloride (1.2 micrograms/ml) was added and then 99mTc was added. Plasma (P) and blood cells (BC) were isolated, also precipitated with trichloroacetic acid and soluble (SF) and insoluble fractions (IF) separated. The analysis of the results shows that there is a decrease in radioactivity (from 97.64 to 75.89 percent) in BC with 34.1 percent of the drug. In the labeling process of RBC with 99mTc, the stannous and pertechnetate ions pass through the membrane, so we suggest that the T. occidentalis effect can be explained (i) by an inhibition of the transport of these ions, (ii) by damage in membrane, (iii) by competition with the cited ions for the same binding sites, or (iv) by possible generation of reactive oxygen species that could oxidize the stannous ion. PMID:9436292
Oliveira, J F; Braga, A C; Avila, A S; Fonseca, L M; Gutfilen, B; Bernardo-Filho, M
1996-01-01
Thuya occidentalis is used in popular medicine in the treatment of condyloma and has antibacterial action. Red blood cells (RBC) labeled with technetium-99m (99mTc) are used for several evaluations in nuclear medicine. This labeling depends on a reducing agent, usually stannous ion. Any drug which alters the labeling of the tracer could be expected to modify the disposition of the radiopharmaceutical. We have evaluated the influence of T. occidentalis extract on the labeling of RBC and plasma proteins with 99mTc. Blood was withdrawn and incubated with T. occidentalis (0.25; 2.5; 20.5; and 34.1 percent v/v). Stannous chloride (1.2 micrograms/ml) was added and then 99mTc was added. Plasma (P) and blood cells (BC) were isolated, also precipitated with trichloroacetic acid and soluble (SF) and insoluble fractions (IF) separated. The analysis of the results shows that there is a decrease in radioactivity (from 97.64 to 75.89 percent) in BC with 34.1 percent of the drug. In the labeling process of RBC with 99mTc, the stannous and pertechnetate ions pass through the membrane, so we suggest that the T. occidentalis effect can be explained (i) by an inhibition of the transport of these ions, (ii) by damage in membrane, (iii) by competition with the cited ions for the same binding sites, or (iv) by possible generation of reactive oxygen species that could oxidize the stannous ion.
Radionuclide Retention Mechanisms in Secondary Waste-Form Testing: Phase II
DOE Office of Scientific and Technical Information (OSTI.GOV)
Um, Wooyong; Valenta, Michelle M.; Chung, Chul-Woo
2011-09-26
This report describes the results from laboratory tests performed at Pacific Northwest National Laboratory (PNNL) for Washington River Protection Solutions (WRPS) to evaluate candidate stabilization technologies that have the potential to successfully treat liquid secondary waste stream effluents produced by the Hanford Tank Waste Treatment and Immobilization Plant (WTP). WRPS is considering the design and construction of a Solidification Treatment Unit (STU) for the Effluent Treatment Facility (ETF) at Hanford. The ETF, a multi-waste, treatment-and-storage unit that has been permitted under the Resource Conservation and Recovery Act (RCRA), can accept dangerous, low-level, and mixed wastewaters for treatment. The STU needsmore » to be operational by 2018 to receive secondary liquid waste generated during operation of the WTP. The STU will provide the additional capacity needed for ETF to process the increased volume of secondary waste expected to be produced by WTP. This report on radionuclide retention mechanisms describes the testing and characterization results that improve understanding of radionuclide retention mechanisms, especially for pertechnetate, {sup 99}TcO{sub 4}{sup -} in four different waste forms: Cast Stone, DuraLith alkali aluminosilicate geopolymer, encapsulated fluidized bed steam reforming (FBSR) product, and Ceramicrete phosphate bonded ceramic. These data and results will be used to fill existing data gaps on the candidate technologies to support a decision-making process that will identify a subset of the candidate waste forms that are most promising and should undergo further performance testing.« less
Tsai, Chi-Jung; Cheng, Cheng-Yi; Shen, Daniel Hueng-Yuan; Kuo, Shou Jen; Wang, Lien-Yen; Lee, Chiang-Hsuan; Wang, Jhi-Joung; Chang, Ming-Che; Huang, Wen-Sheng
2016-02-01
The aim of this study was to evaluate the clinical role of technetium-99m pertechnetate (Tc-99m) imaging in thyroidectomized differentiated thyroid cancer patients immediately before radioiodine-131 (I-131) treatment (Tx). Eighty-six consecutive post-total-thyroidectomy patients (15 men, 71 women; mean age: 46.8 years) with pathologically diagnosed differentiated thyroid cancer were retrospectively studied. Tc-99m imaging immediately before I-131 Tx using both patient-based and lesion-based measurements were analyzed and were further compared with those of post-Tx I-131 whole-body scans. For patients with unequivocally positive Tc-99m uptake, the sensitivity was 77% (patient-based) and 59% (site-based). The positive predictive value (PPV) was 100% for both patient-based and site-based measurements. If equivocal Tc-99m uptake was counted as positive, the sensitivity was 83 and 67%, and the PPV was 100 and 99% for patient-based and site-based measurements, respectively. (a) To increase sensitivity yet maintaining high PPV, equivocal Tc-99m uptake should be considered a positive finding. (b) The nearly 100% PPV of Tc-99m imaging immediately before I-131 Tx for remnant detection suggests that Tc-99m imaging not only serves as an alternative to low-dose I-131 scanning in the low-risk post-thyroidectomy patients but also provides a clue for the subsequent I-131 therapeutic dosage and even for the outcome prediction.
In situ Spectroscopic Analysis and Quantification of [Tc(CO)3]+ in Hanford Tank Waste.
Branch, Shirmir D; French, Amanda D; Lines, Amanda M; Soderquist, Chuck Z; Rapko, Brian M; Heineman, William R; Bryan, Samuel A
2018-06-12
The quantitative conversion of non-pertechnetate [Tc(CO)3]+ species in nuclear waste storage tank 241-AN-102 at the Hanford Site is demonstrated. A waste sample containing the [Tc(CO)3]+ species is added to a developer solution that rapidly converts the non-emissive species into a luminescent complex, which is detected spectroscopically. This method was first demonstrated using a [Tc(CO)3]+ sample non-waste containing matrix to determine a detection limit (LOD), resulting in a [Tc(CO)3]+ LOD of 2.20 × 10-7 M, very near the LOD of the independently synthesized standard (2.10 × 10-7 M). The method was then used to detect [Tc(CO)3]+ in a simulated waste using the standard addition method, resulting in a [Tc(CO)3]+ concentration of 1.89 × 10-5 M (within 27.7% of the concentration determined by β- liquid scintillation counting). Three samples from 241-AN-102 were tested by the standard addition method: (1) a 5 M Na adjusted fraction, (2) a fraction depleted of 137Cs, (3) and an acid-stripped eluate. The concentrations of [Tc(CO)3]+ in these fractions were determined to be 9.90 × 10-6 M (1), 0 M (2), and 2.46 × 10-6 M (3), respectively. The concentration of [Tc(CO)3]+ in the as-received AN-102 tank waste supernatant was determined to be 1.84 × 10-5 M.
Radionuclide thyroid imaging in the newborn with suspected hypothyroidism
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yoosufani, Z.; Karimeddini, M.K.; Spencer, R.P.
1985-05-01
The authors reviewed their experience with thyroid imaging in newborns with suspected congenital hypothyroidism. The infants were selected through a hypothyroidism screening program. There were 19 infants (14 females, 5 males) from 2 to 8 weeks of age with a blood T4 <6 ..mu..g/dl. Thyroid imaging was performed with either IV or IM injection of 0.5 to 1 mCi of Tc 99m pertechnetate using a gamma camera with a pinhole collimator. Salivary glands and stomach were also imaged for assessing the presence of the transport system. In 6 infants (32%) no thyroid tissue was visualized (thyroid hypoplasia). Four infants (21%)more » showed ectopic thyroid tissue in the lingual or sublingual area. Two infants (10%) had evidence of goiter. The remaining 7 infants (37%) had normal appearing glands in size and position. TSH values were markedly elevated (> 100 ..mu mu../ml) in all 10 patients with hypoplastic or ectopic thyroid. Two patients were subsequently found to have normal thyroid function (one with TBG deficiency and one with transient hypothyroidism). Thyroidal as well as salivary gland trapping of the radiotracer in these two infants was clearly less than that of adults suggesting immaturity of the transport/trapping mechanism. All 4 patients with ectopic thyroid had markedly increased uptake of the radiotracer. All other patients with elevated TSH levels had increased uptake of the radiotracer as compared to the normals. They conclude that thyroid scanning is an important tool in delineating the etiology of congenital hypothyroidism.« less
Quantitative thyroid scintigraphy in greyhounds suspected of primary hypothyroidism.
Pinilla, Manuel; Shiel, Robert E; Brennan, Sheila F; McAllister, Hester; Mooney, Carmel T
2009-01-01
The existence of hypothyroidism in greyhounds remains controversial and its investigation is complicated by the low circulating thyroid hormone concentrations typically found in healthy dogs of this breed. Quantitative measurement of thyroidal technetium-99m pertechnetate ((99m)TcO4-) uptake is known to be useful in assessing thyroid function in other breeds. The aim of this study was to evaluate thyroid scintigraphy as a method of assessing thyroid function in greyhounds suspected of primary hypothyroidism. Twenty greyhounds (eight females, 12 males) were studied. Thirteen had bald thigh syndrome and seven poor performance and low total T4. Total T4 concentrations were decreased in 18 (90%), and free T4 in two (10%) dogs. All canine thyroid stimulating hormone concentrations were within the reference interval. Thyroidal (99m)TcO4- uptake values (mean +/- SD, 0.76 +/- 0.26%) were within the reference limits published for euthyroid dogs (0.39-1.86%) making hypothyroidism highly unlikely. There were no significant differences (P < 0.05) when comparing data between dogs with bald thigh syndrome (13 dogs) and the remaining dogs (seven dogs). Seventeen (85%) dogs had higher uptake in the left thyroid gland than in the right that might reflect an anatomic feature of the greyhound breed. Calculation of percent thyroidal uptake of (99m)TcO4- is more accurate than thyroid: salivary gland ratios because of high variability in salivary gland uptake. Percent thyroidal uptake of (99m)TcO4- should be used when assessing thyroid function scintigraphically in the greyhound breed.
Bailey, J J; Dewaraja, Y; Hubers, D; Srinivasa, R N; Frey, K A
2017-10-01
To evaluate the frequency of 99mTc-MAA uptake in extrahepatic organs during 90Y radioembolization therapy planning. This retrospective case series of 70 subjects who underwent 99mTc-MAA hepatic artery perfusion studies between January 2014 and July 2016 for 90Y radioembolization therapy planning at our institution involved direct image review for all subjects, with endpoints recorded: lung shunt fraction, extrahepatic radiotracer uptake, time from MAA injection to imaging. Combined planar and SPECT/CT imaging findings in the 70 subjects demonstrated lung shunt fraction measurements of less than 10% in 53 (76%) subjects and greater than 10% in 17 (24%) subjects. All patients demonstrated renal cortical uptake, 23 (33%) demonstrated salivary gland uptake, 23 (33%) demonstrated thyroid uptake, and 32 (46%) demonstrated gastric mucosal uptake, with significant overlap between these groups. The range of elapsed times between MAA injection and initial imaging was 41-138 min, with a mean of 92 min. There was no correlation between time to imaging and the presence of extrahepatic radiotracer uptake at any site. During hepatic artery perfusion scanning for 90Y radioembolization therapy planning, extrahepatic uptake is common, particularly in the kidney, salivary gland, thyroid and gastric mucosa, and is hypothesized to result from breakdown of 99mTc-MAA over time. Given the breakdown to smaller aggregates and ultimately pertechnetate, this should not be a contraindication to actual Y-90 microsphere therapy. Although we found no correlation between time to imaging and extrahepatic uptake, most of our injection to imaging times were relatively short.
Corkhill, Claire L; Bridge, Jonathan W; Chen, Xiaohui C; Hillel, Phil; Thornton, Steve F; Romero-Gonzalez, Maria E; Banwart, Steven A; Hyatt, Neil C
2013-12-03
We present a novel methodology for determining the transport of technetium-99m, a γ-emitting metastable isomer of (99)Tc, through quartz sand and porous media relevant to the disposal of nuclear waste in a geological disposal facility (GDF). Quartz sand is utilized as a model medium, and the applicability of the methodology to determine radionuclide transport in engineered backfill cement is explored using the UK GDF candidate backfill cement, Nirex Reference Vault Backfill (NRVB), in a model system. Two-dimensional distributions in (99m)Tc activity were collected at millimeter-resolution using decay-corrected gamma camera images. Pulse-inputs of ~20 MBq (99m)Tc were introduced into short (<10 cm) water-saturated columns at a constant flow of 0.33 mL min(-1). Changes in calibrated mass distribution of (99m)Tc at 30 s intervals, over a period of several hours, were quantified by spatial moments analysis. Transport parameters were fitted to the experimental data using a one-dimensional convection-dispersion equation, yielding transport properties for this radionuclide in a model GDF environment. These data demonstrate that (99)Tc in the pertechnetate form (Tc(VII)O4(-)) does not sorb to cement backfill during transport under model conditions, resulting in closely conservative transport behavior. This methodology represents a quantitative development of radiotracer imaging and offers the opportunity to conveniently and rapidly characterize transport of gamma-emitting isotopes in opaque media, relevant to the geological disposal of nuclear waste and potentially to a wide variety of other subsurface environments.
2013-01-01
We present a novel methodology for determining the transport of technetium-99m, a γ-emitting metastable isomer of 99Tc, through quartz sand and porous media relevant to the disposal of nuclear waste in a geological disposal facility (GDF). Quartz sand is utilized as a model medium, and the applicability of the methodology to determine radionuclide transport in engineered backfill cement is explored using the UK GDF candidate backfill cement, Nirex Reference Vault Backfill (NRVB), in a model system. Two-dimensional distributions in 99mTc activity were collected at millimeter-resolution using decay-corrected gamma camera images. Pulse-inputs of ∼20 MBq 99mTc were introduced into short (<10 cm) water-saturated columns at a constant flow of 0.33 mL min–1. Changes in calibrated mass distribution of 99mTc at 30 s intervals, over a period of several hours, were quantified by spatial moments analysis. Transport parameters were fitted to the experimental data using a one-dimensional convection–dispersion equation, yielding transport properties for this radionuclide in a model GDF environment. These data demonstrate that 99Tc in the pertechnetate form (Tc(VII)O4–) does not sorb to cement backfill during transport under model conditions, resulting in closely conservative transport behavior. This methodology represents a quantitative development of radiotracer imaging and offers the opportunity to conveniently and rapidly characterize transport of gamma-emitting isotopes in opaque media, relevant to the geological disposal of nuclear waste and potentially to a wide variety of other subsurface environments. PMID:24147650
DOE Office of Scientific and Technical Information (OSTI.GOV)
Amber Wright; Edward Mausolf; Keri Campbell
2010-05-01
Acetohydroxamic acid (AHA) is an organic ligand planned for use in the Uranium Extraction (UREX) process. It reduces neptunium and plutonium, and the resultant hydrophilic complexes are separated from uranium by extraction with tributyl phosphate (TBP) in a hydrocarbon diluent. AHA undergoes hydrolysis to acetic acid which will impede the recycling of nitric acid. During recent discussions of the UREX process, it has been proposed to replace AHA by formohydroxamic acid (FHA). FHA will undergo hydrolysis to formic acid which is volatile, thus allowing the recycling of nitric acid. The reported reduction potentials of AHA and pertechnetate (TcO{sub 4}{sup -})more » indicated that it may be possible for AHA to reduce technetium, altering its fate in the fuel cycle. At UNLV, it has been demonstrated that TcO{sub 4}{sup -} undergoes reductive nitrosylation by AHA under a variety of conditions. The resulting divalent technetium is complexed by AHA to form the pseudo-octahedral trans-aquonitrosyl (diacetohydroxamic)-technetium(II) complex ([Tc{sup II}(NO)(AHA){sub 2}H{sub 2}O]{sup +}). In this paper, we are reporting the synthesis of FHA and its complex formation with technetium along with the characterization of FHA crystals achieved by NMR and IR spectroscopy. Two experiments were conducted to investigate the complexation of FHA with Tc and the results were compared with previous data on AHA. The first experiment involved the elution of Tc from a Reillex HP anion exchange resin, and the second one monitored the complexation of technetium with FHA by UV-visible spectrophotometry.« less
Bombesin receptors and transplanted stem cells in rat brain: High-resolution scan with 99mTc BN1.1
NASA Astrophysics Data System (ADS)
Scopinaro, F.; Paschali, E.; Di Santo, G.; Antonellis, T.; Massari, R.; Trotta, C.; Gourni, H.; Bouziotis, P.; David, V.; Soluri, A.; Varvarigou, A. D.
2006-12-01
The aim of this work is to detect the presence of transplanted stem cells (TSC) in rat brain with high-resolution (HR) scintigraphy and labelled bombesin (BN). BN is a morphogen for Central Nervous System (CNS) as well as for other organs: CNS-oriented TSC over-express BN Receptors (BNR). BN is also a neurotransmitter and modulates several functions of CNS. 99mTc labelled BN-like peptide scan of CNS is the ideal method to detect growing TSC once knowing normal distribution of BNRs in CNS. HR Planar and single photon emission computerized tomography (SPECT) images of rat brain were performed with new HR detectors (Li-tech, Italy). Pertechnetate, 99mTc HMPAO and the new 99mTc BN1.1 (patented) were i.v. administered in five rats. HR SPECT of 99mTc BN1.1 detected olfactory tract, fronto-lateral cortex, cerebellum, basal ganglia and amygdale. Results of SPECT were confirmed by bio-distribution study performed after autopsy of three of the five rats. The remaining two rats underwent cerebral lesions followed by transplant of TSC. Three months later, HR scintigraphy was repeated and showed images completely different from previous basal study, with hot spot of 99mTc BN1.1 corresponding to the site of TSC transplant. Immuno-histochemistry confirmed the presence of viable TSC. Not only 99mTc BN1.1 HR scan showed viability of transplanted TSC but also the "background brain" was the still now unknown map of BNR in mammalian brain.
Development of a Radiolabeled Amlodipine Analog for L-type Calcium Channel Imaging.
Firouzyar, Tahereh; Jalilian, Amir Reza; Aboudzadeh, Mohammad Reza; Sadeghpour, Hossein; Pooladi, Mehrban; Shafiee-Ardestani, Mahdi; Khalaj, Ali
2017-01-01
The non-invasive imaging and quantification of L-type calcium channels (also known as dihydropyridine channels) in living tissues is of great interest in diagnosis of congestive heart failure, myocardial hypertrophy, irritable bowel syndrome etc. Technetium-99m labeled amlodipine conjugate ([99mTc]-DTPA-AMLO) was prepared starting freshly eluted (<1 h) 99mTechnetium pertechnetate (86.5 MBq) and conjugated DTPAAMLO at pH 5 in 30 min at room temperature in high radiochemical purity (>99%, RTLC; specific activity: 55-60 GBq/mmol). The calcium channel blockade activity (CCBA) and apoptosis/necrosis assay of DTPA-amlodipine conjugate evaluations were performed for the conjugate. Log P, stability, bio-distribution and imaging studies were performed for the tracer followed by biodistribution studies as well as imaging. The conjugate demonstrated low toxicity on MCF-7 cells and CCBA (at µm level) compared to the amlodipine. The tracer was stable up to 4 h in final production and presence of human serum and log P (-0.49) was consistent with a water soluble complex. The tracer was excreted through kidneys and liver as expected for dihydropyridines; excluding excretory organs, calcium channel rich smooth muscle cells; including colon, intestine and lungs which demonstrated significant uptake. SPECT images supported the bio-distribution data up to 4 h. significant uptake of [99mTc]-DTPA-AMLO was obtained in calcium channel rich organs. The complex can be a candidate for further SPECT imaging for L-type calcium channels. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.
Spectroelectrochemical Sensors: New Polymer Films for Improved Sensitivity
DOE Office of Scientific and Technical Information (OSTI.GOV)
Morris, Laura K.; Seliskar, Carl J.; Bryan, Samuel A.
2014-10-31
The selectivity of an optical sensor can be improved by combining optical detection with electrochemical oxidation or reduction of the target analyte to change its spectral properties. The changing signal can distinguish the analyte from interferences with similar spectral properties that would otherwise interfere. The analyte is detected by measuring the intensity of the electrochemically modulated signal. In one form this spectroelectrochemical sensor consists of an optically transparent electrode (OTE) coated with a film that preconcentrates the target analyte. The OTE functions as an optical waveguide for attenuated total reflectance (ATR) spectroscopy, which detects the analyte by absorption. Sensitivity reliesmore » in part on a large change in molar absorptivity between the two oxidation states used for electrochemical modulation of the optical signal. A critical part of the sensor is the ion selective film. It should preconcentrate the analyte and exclude some interferences. At the same time the film must not interfere with the electrochemistry or the optical detection. Therefore, since the debut of the sensor’s concept one major focus of our group has been developing appropriate films for different analytes. Here we report the development of a series of quaternized poly(vinylpyridine)-co-styrene (QPVP-co-S) anion exchange films for use in spectroelectrochemical sensors to enable sensitive detection of target anionic analytes in complex samples. The films were either 10% or 20% styrene and were prepared with varying degrees of quaternized pyridine groups, up to 70%. Films were characterized with respect to thickness with spectroscopic ellipsometry, degree of quaternization with FTIR, and electrochemically and spectroelectrochemically using the anions ferrocyanide and pertechnetate.« less
Peştean, Claudiu; Bărbuş, Elena; Piciu, Andra; Larg, Maria Iulia; Sabo, Alexandrina; Moisescu-Goia, Cristina; Piciu, Doina
2016-01-01
Melanoma is a disease that has an increasing incidence worldwide. Sentinel lymph node scintigraphy is a diagnostic tool that offers important information regarding the localization of the sentinel lymph nodes offering important input data to establish a pertinent and personalized therapeutic strategy. The golden standard in body contouring for sentinel lymph node scintigraphy is to use a planar flood source of Cobalt-57 (Co-57) placed behind the patients, against the gamma camera. The purpose of the study was to determine the performance of the procedure using a flood calibration planar phantom filled with aqueous solution of Technetion-99m (Tc-99m) in comparison with the published data in literature where the gold standard was used. The study was conducted in the Department of Nuclear Medicine of Oncology Institute "Prof. Dr. Ion Chiricuţă" Cluj-Napoca in 95 patients, 31 males and 64 females. The localization of the lesions was grouped by anatomical regions as follows: 23 on lower limbs, 17 on upper limbs, 45 on thorax and 10 on abdomen. The calibration flood phantom containing aqueous solution of Tc-99m pertechnetate was used as planar source to visualize the body contour of the patients for a proper anatomic localization of detected sentinel lymph nodes. The radiopharmaceutical uptake in sentinel lymph nodes has been recorded in serial images following peritumoral injection of 1 ml solution of Tc-99m albumin nanocolloids with an activity of 1 mCi (37 MBq). The used protocol consisted in early acquired planar images within 15 minutes post-injection and delayed images at 2-3 hours and when necessary, additional images at 6-7 hours. The acquisition matrix used was 128×128 pixels for an acquisition time of 5 - 7 minutes. The skin projection of the sentinel lymph nodes was marked on the skin and surgical removal of detected sentinel lymph nodes was performed the next day using a gamma probe for detection and measurements. The sentinel lymph nodes were detected in 92 cases and confirmed with the gamma probe during the surgical procedure. The localization of the lymph nodes was as follows: for the tumors localized on lower limb 23 lymph nodes were localized in inguinal region, for the tumors localized on upper limb, 17 lymph nodes were localized in axilla, for the tumors localized on the thorax, 40 lymph nodes were localized in axilla and 3 were localized in the inguinal region; for the tumors localized on the abdomen, 1 lymph node was localized in axilla and 8 lymph nodes was localized in inguinal region. Regarding the negative sentinel lymph node cases, 2 cases were registered for primarily lesions localized on thorax and 1 for a lesion localized on abdomen. According to histology, 26 cases revealed lymphatic metastatic invasion. Dose rates measured at 1m from the calibrator phantom had an average value of 3.46 μSv/h (SD 0.19) and at 1.4m, the value was 2.57 μSv/h (SD 0.22). Dose rates measured at the same distances from the Co-57 planar flood source had a average values of 32.5μSv/h (SD 0.11) respectively 24.1 μSv/h (SD 0.14). The planar calibration flood phantom is an effective tool for body contouring in sentinel lymph node scintigraphy and offers accurate anatomical information to efficiently localize the detected sentinel lymph nodes in melanoma, being for the first time used and mentioned as a pertinent alternative in our department.
Lenoir, Laurence; Edeline, Julien; Rolland, Yann; Pracht, Marc; Raoul, Jean-Luc; Ardisson, Valérie; Bourguet, Patrick; Clément, Bruno; Boucher, Eveline; Garin, Etienne
2012-05-01
Identifying gastroduodenal uptake of (99m)Tc-macroaggregated albumin (MAA), which is associated with an increased risk of ulcer disease, is a crucial part of the therapeutic management of patients undergoing radioembolization for liver tumours. Given this context, the use of MAA single photon emission computed tomography (SPECT)/CT may be essential, but the procedure has still not been thoroughly evaluated. The aim of this retrospective study was to determine the effectiveness of MAA SPECT/CT in identifying digestive extrahepatic uptake, while determining potential diagnostic pitfalls. Overall, 139 MAA SPECT/CT scans were performed on 103 patients with different hepatic tumour types. Patients were followed up for at least 6 months according to standard requirements. Digestive, or digestive-like, uptake other than free pertechnetate was identified in 5.7% of cases using planar imaging and in 36.6% of cases using SPECT/CT. Uptake sites identified by SPECT/CT included the gastroduodenal region (3.6%), gall bladder (12.2%), portal vein thrombosis (6.5%), hepatic artery (6.5%), coil embolization site (2.1%) as well as falciform artery (5.0%). For 2.1% of explorations, a coregistration error between SPECT and CT imaging could have led to a false diagnosis by erroneously attributing an uptake site to the stomach or gall bladder, when the uptake actually occurred in the liver. SPECT/CT is more efficacious than planar imaging in identifying digestive extrahepatic uptake sites, with extrahepatic uptake observed in one third of scans using the former procedure. However, more than half of the uptake sites in our study were vascular in nature, without therapeutic implications. The risk of coregistration errors must also be kept in mind.
UK audit of quantitative thyroid uptake imaging.
Taylor, Jonathan C; Murray, Anthony W; Hall, David O; Barnfield, Mark C; O'Shaugnessy, Emma R; Carson, Kathryn J; Cullis, James; Towey, David J; Kenny, Bob
2017-07-01
A national audit of quantitative thyroid uptake imaging was conducted by the Nuclear Medicine Software Quality Group of the Institute of Physics and Engineering in Medicine in 2014/2015. The aims of the audit were to measure and assess the variability in thyroid uptake results across the UK and to compare local protocols with British Nuclear Medicine Society (BNMS) guidelines. Participants were invited through a combination of emails on a public mailbase and targeted invitations from regional co-ordinators. All participants were given a set of images from which to calculate quantitative measures and a spreadsheet for capturing results. The image data consisted of two sets of 10 anterior thyroid images, half of which were acquired after administration of Tc-pertechnetate and the other half after administration of I-iodide. Images of the administration syringes or thyroid phantoms were also included. In total, 54 participants responded to the audit. The median number of scans conducted per year was 50. A majority of centres had at least one noncompliance in comparison with BNMS guidelines. Of most concern was the widespread lack of injection-site imaging. Quantitative results showed that both intersite and intrasite variability were low for the Tc dataset. The coefficient of quartile deviation was between 0.03 and 0.13 for measurements of overall percentage uptake. Although the number of returns for the I dataset was smaller, the level of variability between participants was greater (the coefficient of quartile deviation was between 0.17 and 0.25). A UK-wide audit showed that thyroid uptake imaging is still a common test in the UK. It was found that most centres do not adhere to all aspects of the BNMS practice guidelines but that quantitative results are reasonably consistent for Tc-based scans.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fan, Dimin; Anitori, Roberto; Tebo, Bradley M.
2013-04-24
Under anoxic conditions, soluble 99TcO4– can be reduced to less soluble TcO2•nH2O, but the oxide is highly susceptible to reoxidation. Here we investigate an alternative strategy for remediation of Tc-contaminated groundwater whereby sequestration as Tc sulfide is favored by sulfidic conditions stimulated by nano zero-valent iron (nZVI). nZVI was pre-exposed to increasing concentrations of sulfide in simulated Hanford groundwater for 24 hrs to mimic the stages of aquifer sulfate reduction and onset of biotic sulfidogenesis. Solid-phase characterizations of the sulfidated nZVI confirmed the formation of nanocrystalline FeS phases, but higher S/Fe ratios (>0.112) did not result in the formation ofmore » significantly more FeS. The kinetics of Tc sequestration by these materials showed faster Tc removal rates with increasing S/Fe between S/Fe = 0–0.056, but decreasing Tc removal rates with S/Fe > 0.224. The more favorable Tc removal kinetics at low S/Fe could be due to a higher affinity of TcO4– for FeS (over iron oxides), and electron microscopy confirmed that the majority of the Tc was associated with FeS phases. The inhibition of Tc removal at high S/Fe appears to have been caused by excess HS–. X-ray absorption spectroscopy revealed that as S/Fe increased, Tc speciation shifted from TcO2•nH2O to TcS2. The most substantial change of Tc speciation occurred at low S/Fe, coinciding with the rapid increase of Tc removal rate. This agreement further confirms the importance of FeS in Tc sequestration.« less
Huang, Yang Yang; Maurel, Amelie; Hamza, Saud; Jackson, Lee; Al-Ogaili, Zeyad
2018-06-01
To assess the impact of delayed vs immediate pre-operative lymphoscintigraphy (LSG) for sentinel lymph node biopsy in a single Australian tertiary breast cancer centre. Retrospective cohort study analysing patients with breast cancer or DCIS who underwent lumpectomy or mastectomy with pre-operative LSG and intra-operative sentinel lymph node biopsy from January 2015 to June 2016. A total of 182 LSG were performed. Group A patients had day before pre-operative LSG mapping (n = 79) and Group B had LSG mapping on the day of surgery (n = 103). The overall LSG localisation rate was 97.3% and no statistical difference was detected between the two groups. The overall sentinel lymph node biopsies (SLN) were identified in 99.6% of patients. The number of nodes excised was slightly higher in Group A (1.90 vs 1.72); however, this was not statistically significant. In addition, the number of nodes on histopathology and the incidence of second echelon nodal detection were also similar between the two groups without statistical significance. In conclusion, the 2-day LSG protocol had no impact on overall SLNB and LSG detection rates although slightly higher second tier nodes but this did not translate to any difference between the number of harvest nodes between the two groups. The 2-day LSG allows for greater flexibility in theatre planning and more efficient use of theatre time. We recommend a dose of 40 Mbq of Tc99 m pertechnetate-labelled colloid be given day prior to surgery within a 24-hour timeframe. © 2017 The Royal Australian and New Zealand College of Radiologists.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Strand, S.E.; Grafstroem, G.; Kontestabile, E.
In all injection procedures exists a risk for extravasation. For radiopharmaceuticals, the absorbed dose at the injection site can be high because of high activity concentrations. In radionuclide therapy (RNT), this can cause deterministic effects such as tissue necrosis. To estimate the risk for extravasation, we studied various injection techniques at two nuclear medicine clinics. The frequency and magnitude of extravasations was studied in randomly selected patients. Clinic A used peripheral venous cathethers (PVC), and clinic B used direct injections with injection needles (IN). At clinic A 203 patients were investigated and at clinic B 90. All of these patientsmore » were injected with either 99mTc-DTPA, 99mTc-MAA, 99mTc-MDP or pertechnetate. Both arms were imaged with a scintillation camera as soon as possible after the injection. In the case of an extravasation, the retention time at the injection site was determined with multiple imaging, together with volume estimates. The results for PVC injected patients showed one complete extravasation. We also found that in 8% of these patients the remaining activity at the injection site was up to 2%. For the IN injected patients there was none with complete extravasation. However, in 33% of these patients the remaining activity was up to 18%. The locally absorbed doses in these diagnostically investigated patients were estimated with the MIRD formalism to be up to 0.1 Sv (10 rem). Transforming these results to the RNT, the absorbed doses can be up to 1000 times higher. In addition to the calculated absorbed doses, radionuclides localizing to the cell nucleus could enhance the effects.« less
Frederico, Éric H F F; Cardoso, André L B D; Guimarães, Carlos A S; Almeida, Lívia P; Neves, Rosane F; Sá-Caputo, Danúbia C; Moreira-Marconi, Eloá; Dionello, Carla F; Morel, Danielle S; Paineiras-Domingos, Laisa L; Costa-Cavalcanti, Rebeca G; Sousa-Gonçalves, Cintia R; Arnóbio, Adriano; Asad, Nasser R; Bernardo-Filho, Mario
2017-06-30
The aim of the present study was to evaluate the effect of the association of whole body vibration (WBV) exercise with an aqueous extract of coriander on the biodistribution of the radiopharmaceutical sodium pertechnetate, on the concentration of some plasma biomarker, on the feed intake, on the body mass, and on the stool consistency in rats. Rats were divided in four groups and submitted to different treatments for 40 days. The control group (CON) received deionized water. The group treated with coriander (COR) received the extract of coriander. The rats that were exposed to WBV exercises (WBV-E) also received deionized water. A group of animals received coriander and was exposed to WBV (COR + WBV-E). We found in testis a decrease (0.13 ± 0.01 to 0.06 ± 0.03) of the percentages of injected radioactivity per gram (%ATI/g) in the WBV-E in comparison with the COR. There is no significant alteration on the concentrations of the plasma biomarkers. The feed intake showed a statistically significant increase in WBV-E. No significant difference on the body mass was found. The stool analysis showed a statistical difference on the consistency between COR (hard and dry, darker) and all the other groups (normal). In conclusion, it was verified that possible modifications in some biochemical/physiological parameters of the rats submitted to WBV exercise would be capable to increase the feed intake without changing the body mass, and normalizing the stool consistency altered by the coriander supplementation. Further studies are needed to try to understand better the biological effects involving the association of WBV exercise and coriander. © 2017 The Author(s).
Thyrotoxicosis induced by excessive 3,5,3'-triiodothyronine in a dog.
Morré, Wendy A; Panciera, David L; Daniel, Gregory B; Refsal, Kent R; Rick, Markus; Arrington, Kathy
2017-06-15
CASE DESCRIPTION A 7-year-old castrated male Havanese was evaluated at a veterinary teaching hospital because of a 12-week history of hyperactivity, aggression, and progressive weight loss despite a healthy appetite. CLINICAL FINDINGS Tachycardia was the only remarkable finding during physical examination. Serum 3,5,3'-triiodothyronine (T3) and free T3 concentrations were markedly increased, and thyroxine (T4), free T4, and thyroid-stimulating hormone concentrations were at or decreased from the respective reference ranges. Thyroid scintigraphy revealed suppressed uptake of sodium pertechnetate Tc 99m by the thyroid gland but no ectopic thyroid tissue, which was indicative of thyrotoxicosis induced by an exogenous source of T3. TREATMENT AND OUTCOME The dog was hospitalized for 24 hours, and its diet was changed, after which the clinical signs rapidly resolved and serum T3 and free T3 concentrations returned to within the respective reference ranges. This raised suspicion of an exogenous source of T3 in the dog's home environment. Analysis of the commercial beef-based canned food the dog was being fed revealed a high concentration of T3 (1.39 μg/g) and an iodine (82.44 μg/g) concentration that exceeded industry recommendations. No other source of T3 was identified in the dog's environment. CLINICAL RELEVANCE To our knowledge, this is the first report of clinical thyrotoxicosis in a dog induced by exogenous T3, although the source of exogenous T3 was not identified. This case highlights the importance of measuring serum T3 and thyroid-stimulating hormone concentrations in addition to T4 and free T4 concentrations when there is incongruity between clinical findings and thyroid function test results.
Angusti, Tiziana; Pilati, Emanuela; Parente, Antonella; Carignola, Renato; Manfredi, Matteo; Cauda, Simona; Pizzigati, Elena; Dubreuil, Julien; Giammarile, Francesco; Podio, Valerio; Skanjeti, Andrea
2017-09-01
The aim of this study was the assessment of semi-quantified salivary gland dynamic scintigraphy (SGdS) parameters independently and in an integrated way in order to predict primary Sjögren's syndrome (pSS). Forty-six consecutive patients (41 females; age 61 ± 11 years) with sicca syndrome were studied by SGdS after injection of 200 MBq of pertechnetate. In sixteen patients, pSS was diagnosed, according to American-European Consensus Group criteria (AECGc). Semi-quantitative parameters (uptake (UP) and excretion fraction (EF)) were obtained for each gland. ROC curves were used to determine the best cut-off value. The area under the curve (AUC) was used to estimate the accuracy of each semi-quantitative analysis. To assess the correlation between scintigraphic results and disease severity, semi-quantitative parameters were plotted versus Sjögren's syndrome disease activity index (ESSDAI). A nomogram was built to perform an integrated evaluation of all the scintigraphic semi-quantitative data. Both UP and EF of salivary glands were significantly lower in pSS patients compared to those in non-pSS (p < 0.001). ROC curve showed significantly large AUC for both the parameters (p < 0.05). Parotid UP and submandibular EF, assessed by univariated and multivariate logistic regression, showed a significant and independent correlation with pSS diagnosis (p value <0.05). No correlation was found between SGdS semi-quantitative parameters and ESSDAI. The proposed nomogram accuracy was 87%. SGdS is an accurate and reproducible tool for the diagnosis of pSS. ESSDAI was not shown to be correlated with SGdS data. SGdS should be the first-line imaging technique in patients with suspected pSS.
Freudenberg, Robert; Wendisch, Maria; Runge, Roswitha; Wunderlich, Gerd; Kotzerke, Jörg
2012-12-01
Cellular radionuclide uptake increases the heterogeneity of absorbed dose to biological structures. Dose increase depends on uptake yield and emission characteristics of radioisotopes. We used an in vitro model to compare the impact of cellular uptake of (188)Re-perrhenate and (99m)Tc-pertechnetate on cellular survival. Rat thyroid PC Cl3 cells in culture were incubated with (188)Re or (99m)Tc in the presence or absence of perchlorate for 1 hour. Clonogenic cell survival was measured by colony formation. In addition, intracellular radionuclide uptake was quantified. Dose effect curves were established for (188)Re and (99m)Tc for various extra- and intracellular distributions of the radioactivity. In the presence of perchlorate, no uptake of radionuclides was detected and (188)Re reduced cell survival more efficiently than (99m)Tc. A(37), the activity that is necessary to yield 37% cell survival was 14 MBq/ml for (188)Re and 480 MBq/ml for (99m)Tc. In the absence of perchlorate, both radionuclides showed similar uptakes; however, A(37) was reduced by 30% for the beta-emitter and by 95% for (99m)Tc. The dose D(37) that yields 37% cell survival was between 2.3 and 2.8 Gy for both radionuclides. Uptake of (188)Re and (99m)Tc decreased cell survival. Intracellular (99m)Tc yielded a dose increase that was higher compared to (188)Re due to emitted Auger and internal conversion-electrons. Up to 5 Gy there was no difference in radiotoxicity of (188)Re and (99m)Tc. At doses higher than 5 Gy intracellular (99m)Tc became less radiotoxic than (188)Re, probably due to a non-uniform lognormal radionuclide uptake.
Wong, Ka-Kit; Gandhi, Arpit; Viglianti, Benjamin L; Fig, Lorraine M; Rubello, Domenico; Gross, Milton D
2016-01-01
AIM: To review the benefits of single photon emission computed tomography (SPECT)/computed tomography (CT) hybrid imaging for diagnosis of various endocrine disorders. METHODS: We performed MEDLINE and PubMed searches using the terms: “SPECT/CT”; “functional anatomic mapping”; “transmission emission tomography”; “parathyroid adenoma”; “thyroid cancer”; “neuroendocrine tumor”; “adrenal”; “pheochromocytoma”; “paraganglioma”; in order to identify relevant articles published in English during the years 2003 to 2015. Reference lists from the articles were reviewed to identify additional pertinent articles. Retrieved manuscripts (case reports, reviews, meta-analyses and abstracts) concerning the application of SPECT/CT to endocrine imaging were analyzed to provide a descriptive synthesis of the utility of this technology. RESULTS: The emergence of hybrid SPECT/CT camera technology now allows simultaneous acquisition of combined multi-modality imaging, with seamless fusion of three-dimensional volume datasets. The usefulness of combining functional information to depict the bio-distribution of radiotracers that map cellular processes of the endocrine system and tumors of endocrine origin, with anatomy derived from CT, has improved the diagnostic capability of scintigraphy for a range of disorders of endocrine gland function. The literature describes benefits of SPECT/CT for 99mTc-sestamibi parathyroid scintigraphy and 99mTc-pertechnetate thyroid scintigraphy, 123I- or 131I-radioiodine for staging of differentiated thyroid carcinoma, 111In- and 99mTc- labeled somatostatin receptor analogues for detection of neuroendocrine tumors, 131I-norcholesterol (NP-59) scans for assessment of adrenal cortical hyperfunction, and 123I- or 131I-metaiodobenzylguanidine imaging for evaluation of pheochromocytoma and paraganglioma. CONCLUSION: SPECT/CT exploits the synergism between the functional information from radiopharmaceutical imaging and anatomy from CT, translating to improved diagnostic accuracy and meaningful impact on patient care. PMID:27358692
Beaumont, Hanneke; Bennink, Roelof J; de Jong, Jan; Boeckxstaens, Guy E
2010-04-01
Gastro-oesophageal reflux occurs twice as much during transient lower oesophageal sphincter relaxations (TLOSRs) in patients with gastro-oesophageal reflux disease (GORD) compared to healthy volunteers (HVs). Our aim was to assess whether the localisation of the postprandial acid pocket and its interaction with a hiatal hernia (HH) play a role in the occurrence of acidic reflux during TLOSRs. Ten HVs and 22 patients with GORD (12 with HH<3 cm (s-HH), 10 with HH > or =3 cm (l-HH)) were studied. The squamocolumnar junction and diaphragmatic impression were marked with a radioactively labelled clip. To visualise the acid pocket, (99m)Tc-pertechnetate was injected intravenously and images were acquired up to 2 h postprandial. Concurrently, combined manometry/impedance and four-channel pH-metry were performed, with pH pull-through at multiple time-points. The rate of TLOSRs and the per cent associated with reflux was comparable between all groups. However, acidic reflux was significantly increased in patients, especially in patients with l-HH. Acid pocket length was significantly enlarged in patients. Moreover, immediately before a TLOSR, the acid pocket was more frequently located within the hiatus or above the diaphragm in patients with GORD (s-HH, 54%; l-HH, 77%) compared to HVs (22% of TLOSRs). Acidic reflux was significantly increased when the acid pocket was located above the diaphragm in all groups compared to a sub-diaphragmatic localisation. The position of the acid pocket is largely determined by the presence of a HH. Entrapment of the pocket above the diaphragm, especially in patients with l-HH, is a major risk factor underlying the increased occurrence of acidic reflux during a TLOSR in patients with GORD.
99 Tc NMR determination of the oxygen isotope content in 18 O-enriched water.
Tarasov, Valerii P; Kirakosyan, Gayana А; German, Konstantin E
2018-03-01
99 Tc NMR has been suggested as an original method of evaluating the content of oxygen isotopes in oxygen-18-enriched water, a precursor for the production of radioisotope fluorine-18 used in positron emission tomography. To this end, solutions of NH 4 TcO 4 or NaTcO 4 (up to 0.28 mol/L) with natural abundance of oxygen isotopes in virgin or recycled 18 O-enriched water have been studied by 99 Tc NMR. The method is based on 16 O/ 17 O/ 18 O intrinsic isotope effects in the 99 Tc NMR chemical shifts, and the statistical distribution of oxygen isotopes in the coordination sphere of TcO 4 - and makes it possible to quantify the composition of enriched water by measuring the relative intensities of the 99 Tc NMR signals of the Tc 16 O 4-n 18 O n - isotopologues. Because the oxygen exchange between TcO 4 - and enriched water in neutral and alkaline solutions is characterized by slow kinetics, gaseous HCl was bubbled through a solution for a few seconds to achieve the equilibrium distribution of oxygen isotopes in the Tc coordination sphere without distortion of the oxygen composition of the water. Pertechnetate ion was selected as a probe due to its high stability in solutions and the significant 99 Tc NMR shift induced by a single 16 O→ 18 O substitution (-0.43 ± 0.01 ppm) in TcO 4 - and spin coupling constant 1 J( 99 Tc- 17 O) (131.46 Hz) favourable for the observation of individual signals of Tc 16 O 4-n 18 O n - isotopologues. Copyright © 2017 John Wiley & Sons, Ltd.
[Combined internal-external radiotherapy (CIERT) in a cell model].
Oehme, Liane; Bartzsch, Thomas; Maucksch, Ute; Freudenberg, Robert; Wunderlich, Gerd; Kotzerke, Jörg
2018-06-01
Combined internal-external radiotherapy (CIERT) requires a unified assessment of biologic radiation effects in addition to the total dose. The concept of biological effective dose (BED) was evaluated in a cell model. The thyroid NIS-positive cell line FRTL-5 was irradiated with X-ray and the radiotracer Tc-99m pertechnetate either alone or in combination. The cellular uptake of the radionuclide during the incubation time of 24 h was controlled by the presence or absence of perchlorate. Dose calculation was performed based on measured uptake values. Cell specific radiobiologic parameters were derived from dose effect curves using the colony forming assay as biological endpoint. For the combination of the radiation qualities the sequence and time difference were varied. Cell survival was compared with the prediction of the BED model. The radiobiologic parameters from X-ray dose response were α = (0.22 ± 0.02) Gy -1 and β = (0.021 ± 0.001) Gy -2 . The half life for repair was (1.51 ± 0.21) h. These values could also explain the dose response curves for Tc-99m-irradiation with exponential decreasing dose rate. CIERT experiments showed no significant differences in cell survival regarding sequence and irradiation break. When the radionuclide uptake was not prevented the cell survival for the combination of X-ray and Tc-99m was lower than the prediction by BED calculations. The validity of the BED formalism for different dose rates and radiation qualities was verified. Supraaddive effects measured in the combination of X-ray and intracellular Tc-99m might be caused by Auger and conversion electrons, however further experiments are necessary. Schattauer GmbH.
Effect of nitrate on uptake of pertechnetate by tomato plants
DOE Office of Scientific and Technical Information (OSTI.GOV)
Krijger, G.C.; Kolloeffel, C.; Wolterbeek, H.T.
Nitrate has been shown to affect the acquisition of the nuclear waste product technetium (Tc) by plants. The mechanism responsible for this phenomenon is unknown. The uptake of [{sup 99m}Tc]TcO{sub 4}{sup {minus}},[{sup 35}S] SO{sub 4}{sup 2{minus}} and H{sub 2}[{sup 32P}]PO{sub 4}{sup {minus}} was studied in tomato plants (Lycopersicon esculentum Mill., cv. Tiny Tim) with different growth rates due to culture at 0.5, 4.0, or 30 mM NO{sub 3}{sup {minus}}. In experiments lasting 24 h, net TcO{sub 4}{sup {minus}} uptake decreased at higher NO{sub 3}{sup {minus}} supplies. The inhibitory effect of NO{sub 3}{sup {minus}} on TcO{sub 4}{sup {minus}} uptake also wasmore » shown in TcO{sub 4}{sup {minus}} influx experiments (K{sub i} = 3.3 mM), although about 30% of the TcO{sub 4}{sup {minus}} influx is suggested to be insensitive to NO{sub 3}{sup {minus}}. In contrast, H{sub 2}PO{sub 4}{sup {minus}} (30 mM) did not inhibit TcO{sub 4}{sup {minus}} influx, whereas SO{sub 4}{sup 2{minus}} (30 mM) tended to increase TcO{sub 4}{sup {minus}} influx, probably due to the ionic strength of the uptake solution. Significant effects of the NO{sub 3}{sup {minus}} supply on Tc efflux were not found. Overall, this leads to the conclusion that TcO{sub 4}{sup {minus}} and NO{sub 3}{sup {minus}} share at least one transporter.« less
Guggenberg, Elisabeth Von; Mikolajczak, Renata; Janota, Barbara; Riccabona, Georg; Decristoforo, Clemens
2004-10-01
[(99m)Tc-EDDA-HYNIC-D-Phe(1),Tyr(3)]-Octreotide ((99m)Tc-EDDA/HYNIC-TOC) is a promising new radiopharmaceutical with the potential to replace [(111)In-DTPA-D-Phe(1)]-Octreotide ((111)In-DTPA-OCT) as the radiopharmaceutical for somatostatin receptor scintigraphy due to the advantage of improved image quality, lower radiation dose for the patient, and daily availability. Here we describe the development of a freeze-dried kit formulation based on the Tricine/EDDA exchange labeling approach for the preparation of this radiopharmaceutical in a clinical setting. Three parameters were of major importance to achieve a suitable formulation with a radiochemical purity (RCP) >90%: addition of bulking agent, the pH of the freeze-drying solution, and the content of stannous chloride. The final formulation consisted of 20 mg Tricine, 10 mg EDDA, 50 mg Mannitol, 20 microg SnCl(2). 2H(2)O, and 20 microg [HYNIC-D-Phe(1), Tyr(3)]-Octreotide (HYNIC-TOC). Radiolabeling was performed by addition of 0.2 M Na(2)HPO(4) to adjust the pH to 6-7, followed by 0.5-2 GBq (99m)Tc sodium pertechnetate, in a total volume of 2 mL and incubation for 10 min in a boiling water bath. Mean RCP values of 10 batches showed values >90% over a storage period of up to 1 year, a high stability up to 24 h of the final preparation, and retained biological activity. The developed kit formulation forms the basis for further clinical evaluation of this promising new radiopharmaceutical. Copyright 2004 Wiley-Liss, Inc. and the American Pharmacists Association
Ferro-Flores, Guillermina; Arteaga de Murphy, Consuelo; Rodriguez-Cortés, Jeanette; Pedraza-López, Martha; Ramírez-Iglesias, María Teresa
2006-04-01
Bombesin is a peptide that was initially isolated from frog skin and which belongs to a large group of neuropeptides with many biological functions. The human equivalent is gastrin-releasing peptide (GRP), whose receptors are over-expressed in a variety of malignant tumours. To prepare a HYNIC-[Lys 3]-bombesin analogue that could be easily labelled with 99mTc from lyophilized kit formulations and to evaluate its potential as an imaging agent for GRP receptor-positive tumours. HYNIC was conjugated to the epsilon-amino group of Lys 3 residue at the N-terminal region of bombesin via succinimidyl-N-Boc-HYNIC at pH 9.0. 99mTc labelling was performed by addition of sodium pertechnetate solution and 0.2 M phosphate buffer pH 7.0 to a lyophilized formulation. Stability studies were carried out by reversed phase HPLC and ITLC-SG analyses in serum and cysteine solutions. In-vitro internalization was tested using human prostate cancer PC-3 cells with blocked and non-blocked receptors. Biodistribution and tumour uptake were determined in PC-3 tumour-bearing nude mice. 99mTc-EDDA/HYNIC-[Lys 3]-bombesin was obtained with radiochemical purities >93% and high specific activity ( approximately 0.1 GBq.nmol). Results of in-vitro studies demonstrated a high stability in serum and cysteine solutions, specific cell receptor binding and rapid internalization. Biodistribution data showed a rapid blood clearance, with predominantly renal excretion and specific binding towards GRP receptor-positive tissues such as pancreas and PC-3 tumours. 99mTc-EDDA/HYNIC-[Lys 3]-bombesin obtained from lyophilized kit formulations has promising characteristics for the diagnosis of malignant tumours that over-express the GRP receptor.
Cardoso, André L.B.D.; Guimarães, Carlos A.S.; Almeida, Lívia P.; Neves, Rosane F.; Sá-Caputo, Danúbia C.; Moreira-Marconi, Eloá; Dionello, Carla F.; Morel, Danielle S.; Paineiras-Domingos, Laisa L.; Costa-Cavalcanti, Rebeca G.; Sousa-Gonçalves, Cintia R.; Arnóbio, Adriano; Asad, Nasser R.; Bernardo-Filho, Mario
2017-01-01
The aim of the present study was to evaluate the effect of the association of whole body vibration (WBV) exercise with an aqueous extract of coriander on the biodistribution of the radiopharmaceutical sodium pertechnetate, on the concentration of some plasma biomarker, on the feed intake, on the body mass, and on the stool consistency in rats. Rats were divided in four groups and submitted to different treatments for 40 days. The control group (CON) received deionized water. The group treated with coriander (COR) received the extract of coriander. The rats that were exposed to WBV exercises (WBV-E) also received deionized water. A group of animals received coriander and was exposed to WBV (COR + WBV-E). We found in testis a decrease (0.13 ± 0.01 to 0.06 ± 0.03) of the percentages of injected radioactivity per gram (%ATI/g) in the WBV-E in comparison with the COR. There is no significant alteration on the concentrations of the plasma biomarkers. The feed intake showed a statistically significant increase in WBV-E. No significant difference on the body mass was found. The stool analysis showed a statistical difference on the consistency between COR (hard and dry, darker) and all the other groups (normal). In conclusion, it was verified that possible modifications in some biochemical/physiological parameters of the rats submitted to WBV exercise would be capable to increase the feed intake without changing the body mass, and normalizing the stool consistency altered by the coriander supplementation. Further studies are needed to try to understand better the biological effects involving the association of WBV exercise and coriander. PMID:28507199
Wildung, R. E.; Gorby, Y. A.; Krupka, K. M.; Hess, N. J.; Li, S. W.; Plymale, A. E.; McKinley, J. P.; Fredrickson, J. K.
2000-01-01
To help provide a fundamental basis for use of microbial dissimilatory reduction processes in separating or immobilizing 99Tc in waste or groundwaters, the effects of electron donor and the presence of the bicarbonate ion on the rate and extent of pertechnetate ion [Tc(VII)O4−] enzymatic reduction by the subsurface metal-reducing bacterium Shewanella putrefaciens CN32 were determined, and the forms of aqueous and solid-phase reduction products were evaluated through a combination of high-resolution transmission electron microscopy, X-ray absorption spectroscopy, and thermodynamic calculations. When H2 served as the electron donor, dissolved Tc(VII) was rapidly reduced to amorphous Tc(IV) hydrous oxide, which was largely associated with the cell in unbuffered 0.85% NaCl and with extracellular particulates (0.2 to 0.001 μm) in bicarbonate buffer. Cell-associated Tc was present principally in the periplasm and outside the outer membrane. The reduction rate was much lower when lactate was the electron donor, with extracellular Tc(IV) hydrous oxide the dominant solid-phase reduction product, but in bicarbonate systems much less Tc(IV) was associated directly with the cell and solid-phase Tc(IV) carbonate may have been present. In the presence of carbonate, soluble (<0.001 μm) electronegative, Tc(IV) carbonate complexes were also formed that exceeded Tc(VII)O4− in electrophoretic mobility. Thermodynamic calculations indicate that the dominant reduced Tc species identified in the experiments would be stable over a range of Eh and pH conditions typical of natural waters. Thus, carbonate complexes may represent an important pathway for Tc transport in anaerobic subsurface environments, where it has generally been assumed that Tc mobility is controlled by low-solubility Tc(IV) hydrous oxide and adsorptive, aqueous Tc(IV) hydrolysis products. PMID:10831424
Price, Dominique N; McBride, Amber A; Anton, Martina; Kusewitt, Donna F; Norenberg, Jeffrey P; MacKenzie, Debra A; Thompson, Todd A; Muttil, Pavan
2016-01-01
Lung cancer has the highest mortality rate of any tissue-specific cancer in both men and women. Research continues to investigate novel drugs and therapies to mitigate poor treatment efficacy, but the lack of a good descriptive lung cancer animal model for preclinical drug evaluation remains an obstacle. Here we describe the development of an orthotopic lung cancer animal model which utilizes the human sodium iodide symporter gene (hNIS; SLC5A5) as an imaging reporter gene for the purpose of non-invasive, longitudinal tumor quantification. hNIS is a glycoprotein that naturally transports iodide (I-) into thyroid cells and has the ability to symport the radiotracer 99mTc-pertechnetate (99mTcO4-). A549 lung adenocarcinoma cells were genetically modified with plasmid or lentiviral vectors to express hNIS. Modified cells were implanted into athymic nude mice to develop two tumor models: a subcutaneous and an orthotopic xenograft tumor model. Tumor progression was longitudinally imaged using SPECT/CT and quantified by SPECT voxel analysis. hNIS expression in lung tumors was analyzed by quantitative real-time PCR. Additionally, hematoxylin and eosin staining and visual inspection of pulmonary tumors was performed. We observed that lentiviral transduction provided enhanced and stable hNIS expression in A549 cells. Furthermore, 99mTcO4- uptake and accumulation was observed within lung tumors allowing for imaging and quantification of tumor mass at two-time points. This study illustrates the development of an orthotopic lung cancer model that can be longitudinally imaged throughout the experimental timeline thus avoiding inter-animal variability and leading to a reduction in total animal numbers. Furthermore, our orthotopic lung cancer animal model is clinically relevant and the genetic modification of cells for SPECT/CT imaging can be translated to other tissue-specific tumor animal models.
Anton, Martina; Kusewitt, Donna F.; Norenberg, Jeffrey P.; MacKenzie, Debra A.; Thompson, Todd A.; Muttil, Pavan
2016-01-01
Lung cancer has the highest mortality rate of any tissue-specific cancer in both men and women. Research continues to investigate novel drugs and therapies to mitigate poor treatment efficacy, but the lack of a good descriptive lung cancer animal model for preclinical drug evaluation remains an obstacle. Here we describe the development of an orthotopic lung cancer animal model which utilizes the human sodium iodide symporter gene (hNIS; SLC5A5) as an imaging reporter gene for the purpose of non-invasive, longitudinal tumor quantification. hNIS is a glycoprotein that naturally transports iodide (I-) into thyroid cells and has the ability to symport the radiotracer 99mTc-pertechnetate (99mTcO4-). A549 lung adenocarcinoma cells were genetically modified with plasmid or lentiviral vectors to express hNIS. Modified cells were implanted into athymic nude mice to develop two tumor models: a subcutaneous and an orthotopic xenograft tumor model. Tumor progression was longitudinally imaged using SPECT/CT and quantified by SPECT voxel analysis. hNIS expression in lung tumors was analyzed by quantitative real-time PCR. Additionally, hematoxylin and eosin staining and visual inspection of pulmonary tumors was performed. We observed that lentiviral transduction provided enhanced and stable hNIS expression in A549 cells. Furthermore, 99mTcO4- uptake and accumulation was observed within lung tumors allowing for imaging and quantification of tumor mass at two-time points. This study illustrates the development of an orthotopic lung cancer model that can be longitudinally imaged throughout the experimental timeline thus avoiding inter-animal variability and leading to a reduction in total animal numbers. Furthermore, our orthotopic lung cancer animal model is clinically relevant and the genetic modification of cells for SPECT/CT imaging can be translated to other tissue-specific tumor animal models. PMID:28036366
Chen, Jinlong; Pang, Wensheng; Shi, Wentao; Yang, Bin; Kan, Yongjun; He, Zhaodong; Hu, Juan
2016-09-14
The semi-refined polysaccharide of Pseudostellaria heterophylla is a complex polysaccharide that exhibits significantly hypoglycemic activities. A novel homogeneous polysaccharide, named as H-1-2, was isolated from the semi-refined polysaccharide. The mean molecular weight of H-1-2 was 1.4 × 10⁴ Da and it was only composed of d-glucose monosaccharide. Structure elucidation indicated that H-1-2 contains pyranride, and has the characteristics of the α-iso-head configuration, a non-reducing end (T-), 4-, 1,6-, and 1,4,6-connection, in all four ways to connect glucose. H-1-2 was a type of glucan, where chemical combination exists in the main chain between 1→4 linked glucose, and contains a small amount of 1,6-linked glucose, which was in the branched chain. In vitro HepG2, 3T3-L1, and L6 cells were used to assess cellular glucose consumption and cellular glucose uptake by glucose oxidase, and the transport of 2-NBDG fluorescence probe results showed that H-1-2 could clearly increase glucose uptake and utilization in muscle and adipose cells, which is beneficial to screen for in the discovery of anti-diabetes lead compounds. H-1-2 was labeled with radioisotopes ((99m)Tc-pertechnetate). (99m)Tc-labeled-H-1-2 was performed by SPECT/CT analysis images after oral administration in rats. At 4 h post ingestion, about 50% of the radioactivity was observed in the intestine. No significant radioactivity was found in the heart, liver, and kidney, conjecturing that absorption of (99m)Tc-labeled H-1-2 might, via intestinal mucosa, be absorbed into systemic circulation. This problem, as to whether the polysaccharide is absorbed orally, will need further examination.
Lumachi, F; Marzola, M C; Zucchetta, P; Tregnaghi, A; Cecchin, D; Bui, F
2003-09-01
A series of 112 consecutive patients with primary hyperparathyroidism who underwent both high-resolution neck ultrasonography (US) and 99mTc-sestamibi/99mTc-pertechnetate subtraction scintigraphy (SS) prior to successful parathyroidectomy was reviewed. There were 29 (25.9%) men and 83 (74.1%) women, with a median age of 58 years (range 13-78 years). Patients were divided into two groups, according to the preoperative US findings: group A (87 patients, 77.7%) without thyroid diseases, and group B (25 patients, 22.3%) with either multinodular goitre or a solitary nontoxic thyroid nodule. In group B patients partial or total thyroidectomy was also performed, according to the intraoperative findings and frozen-section examination results. Final histopathology showed 99 (88.4%) solitary parathyroid (PT) adenomas and 3 (2.7%) PT carcinomas, while 10 (8.9%) patients had a multiglandular disease. The sensitivity and positive predictive value (PPV) were (group A vs group B) 79.8% vs 70.8% (P=0.25) and 95.7% vs 94.4% (P=0.58) for US, and 83.3% vs 87.0% (P=0.47) and 95.9% vs 90.9% (P=0.32) for SS respectively. Better but similar (P=not significant) results were obtained in patients with solitary PT tumours: 81.5% vs 77.8% (US) and 85.0 vs 94.1% (SS) sensitivity; 97.1% vs 93.3% (US) and 95.8% vs 88.9% (SS) PPV. Overall, the combination of US and SS was 92.9% sensitive (group A=93.1%, group B=92.0%; P=0.55), and the PPV reached 100% in each group. In conclusion, in patients with primary hyperparathyroidism the results of both US and SS are independent of coexistent thyroid disease, especially in patients with solitary PT tumours.
Peterson, Mark E; Guterl, Jade N; Rishniw, Mark; Broome, Michael R
2016-07-01
Thyroid scintigraphy is commonly used for evaluation of cats with hyperthyroidism, with the thyroid-to-salivary ratio (T/S) being the most common method to quantify the degree of thyroid activity and disease. Calculation of thyroid-to-background ratios (T/B) or percent thyroidal uptake of (99m) TcO(-) 4 (TcTU) has only been reported in a few studies. The purpose of this prospective, cross-sectional study was to evaluate a number of quantitative scintigraphic indices as diagnostic tests for hyperthyroidism, including the T/S, three different T/B, TcTU, and estimated thyroid volume. Of 524 cats referred to our clinic for evaluation of suspected hyperthyroidism, the diagnosis was confirmed (n = 504) or excluded (n = 20) based on results of a serum thyroid panel consisting of thyroxine (T4 ), triiodothyronine (T3 ), free T4 (fT4 ), and thyroid-stimulating hormone (TSH) concentrations. In the hyperthyroid cats, median values for TcTU, T/S, and three T/B ratios were all significantly higher (P < 0.001) than values in euthyroid suspect cats or clinically normal cats. All scintigraphic parameters were relatively sensitive and specific as diagnostic tests for hyperthyroidism, but the T/S ratio had the highest test accuracy. The T/S ratio correlated strongly with the TcTU (r = 0.85). However, the TcTU had a higher and more significant correlation (P < 0.01) with serum T4 (r = 0.76 vs. 0.64), T3 (r = 0.77 vs. 0.64), and estimated thyroid volume (r = 0.62 vs. 0.38). Overall, calculation of TcTU is an accurate diagnostic test, but also appears to be the best parameter to predict the functional volume and metabolic activity of the feline adenomatous thyroid gland. © 2016 American College of Veterinary Radiology.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Antipov, B.G.; Kryuchkov, S.V.; Grigor`ev, M.S.
1995-09-01
New technetium and rhenium compounds with ferricenium cations - [Fe(C{sub 5}H{sub 5}){sub 2}]{sub 3}[Tc{sub 6}I{sub 14}], [Fe(C{sub 5}H{sub 5}){sub 2}]{sub 3}[Tc{sub 6}Cl{sub 14}], [Fe(C{sub 5}H{sub 5}){sub 2}]{sub 2}[Tc{sub 8}Br{sub 14}], and [Fe(C{sub 5}H{sub 5}){sub 2}]{sub 2}[Re{sub 2}Br{sub 8}] - are synthesized and identified. The compounds are characterized by the methods of static magnetic susceptibility and differential scanning calorimetry; solid-state conductivity measurements; and IR, EPR, {sup 57}Fe Moessbauer, and X-ray photoelectron spectroscopic data. These data are compared with the physicochemical characteristics of ferricenium pertechnetate and hexachlorotechnetate, as well as of a number of reference technetium and rhenium compounds containing the samemore » anions but different cations. The structure of [Fe(C{sub 5}H{sub 5}){sub 2}]{sub 3}[Tc{sub 6}I{sub 14}] is determined by X-ray diffraction analysis of a single crystal [space group P6/m, a = 15.34(2), c = 12.70(1) {angstrom}]. The structures of the remaining compounds were confirmed by comparing their spectroscopic properties with corresponding properties of compounds with known composition and structure. None of the compounds with ferricenium cations exhibit covalent or other localized bonds between anions and cations. However, the physicochemical properties of these compounds indicate the occurrence of a fast dynamic electron transfer along infinite anion-cation chains. Compounds [Fe(C{sub 5}H{sub 5}){sub 2}]{sub 3}[Tc{sub 6}Cl{sub 14}] and [Fe(C{sub 5}H{sub 5}){sub 2}]{sub 2}[Tc{sub 8}Br{sub 14}] were found to exhibit a new phenomenon of X-ray-induced low-temper ature high-energy electron emission.« less
Kim, Hyun Joo; Bang, Ji-In; Kim, Ji-Young; Moon, Jae Hoon; So, Young
2017-01-01
Objective Since Graves' disease (GD) is resistant to antithyroid drugs (ATDs), an accurate quantitative thyroid function measurement is required for the prediction of early responses to ATD. Quantitative parameters derived from the novel technology, single-photon emission computed tomography/computed tomography (SPECT/CT), were investigated for the prediction of achievement of euthyroidism after methimazole (MMI) treatment in GD. Materials and Methods A total of 36 GD patients (10 males, 26 females; mean age, 45.3 ± 13.8 years) were enrolled for this study, from April 2015 to January 2016. They underwent quantitative thyroid SPECT/CT 20 minutes post-injection of 99mTc-pertechnetate (5 mCi). Association between the time to biochemical euthyroidism after MMI treatment and %uptake, standardized uptake value (SUV), functional thyroid mass (SUVmean × thyroid volume) from the SPECT/CT, and clinical/biochemical variables, were investigated. Results GD patients had a significantly greater %uptake (6.9 ± 6.4%) than historical control euthyroid patients (n = 20, 0.8 ± 0.5%, p < 0.001) from the same quantitative SPECT/CT protocol. Euthyroidism was achieved in 14 patients at 156 ± 62 days post-MMI treatment, but 22 patients had still not achieved euthyroidism by the last follow-up time-point (208 ± 80 days). In the univariate Cox regression analysis, the initial MMI dose (p = 0.014), %uptake (p = 0.015), and functional thyroid mass (p = 0.016) were significant predictors of euthyroidism in response to MMI treatment. However, only %uptake remained significant in a multivariate Cox regression analysis (p = 0.034). A %uptake cutoff of 5.0% dichotomized the faster responding versus the slower responding GD patients (p = 0.006). Conclusion A novel parameter of thyroid %uptake from quantitative SPECT/CT is a predictive indicator of an early response to MMI in GD patients. PMID:28458607
DOE Office of Scientific and Technical Information (OSTI.GOV)
Negus, Ian S.; Holmes, Robin B.; Thorne, Gareth C.
Purpose: To make an adaptable, head shaped radionuclide phantom to simulate molecular imaging of the brain using clinical acquisition and reconstruction protocols. This will allow the characterization and correction of scanner characteristics, and improve the accuracy of clinical image analysis, including the application of databases of normal subjects. Methods: A fused deposition modeling 3D printer was used to create a head shaped phantom made up of transaxial slabs, derived from a simulated MRI dataset. The attenuation of the printed polylactide (PLA), measured by means of the Hounsfield unit on CT scanning, was set to match that of the brain bymore » adjusting the proportion of plastic filament and air (fill ratio). Transmission measurements were made to verify the attenuation of the printed slabs. The radionuclide distribution within the phantom was created by adding {sup 99m}Tc pertechnetate to the ink cartridge of a paper printer and printing images of gray and white matter anatomy, segmented from the same MRI data. The complete subresolution sandwich phantom was assembled from alternate 3D printed slabs and radioactive paper sheets, and then imaged on a dual headed gamma camera to simulate an HMPAO SPECT scan. Results: Reconstructions of phantom scans successfully used automated ellipse fitting to apply attenuation correction. This removed the variability inherent in manual application of attenuation correction and registration inherent in existing cylindrical phantom designs. The resulting images were assessed visually and by count profiles and found to be similar to those from an existing elliptical PMMA phantom. Conclusions: The authors have demonstrated the ability to create physically realistic HMPAO SPECT simulations using a novel head-shaped 3D printed subresolution sandwich method phantom. The phantom can be used to validate all neurological SPECT imaging applications. A simple modification of the phantom design to use thinner slabs would make it suitable for use in PET.« less
Dolezal, Jiri; Vizda, Jaroslav; Kopacova, Marcela
2011-01-01
To present our experience with the detection of bleeding in the small intestine by means of scintigraphy with in vivo-labelled red blood cells (RBCs) in the period of 1998-2009. A 12-year prospective study was accomplished with 40 patients (23 men, 17 women, aged 12-91, mean 56 years) who had lower gastrointestinal bleeding (obscure-overt bleeding) and underwent scintigraphy with in vivo-labelled RBCs by means of technetium 99m. The scintigraphy was usually performed after other diagnostic tests had failed to locate the bleeding. A total of 26 patients had a positive scintigraphy with in vivo-labelled RBCs and 14 patients had negative scintigraphy. The final diagnosis was confirmed in 20 of 26 patients with a positive scintigraphy by push enteroscopy (6/20), intraoperative enteroscopy (7/20), surgery (4/20), duodenoscopy (1/20), double-balloon enteroscopy (1/20) and X-ray angiography (1/20). The correct location of the bleeding site was identified by RBC scintigraphy in 15 of 20 (75%) patients with the confirmed source. The locations of the bleeding site identified by scintigraphy and enteroscopy (push, intraoperative) and surgical investigations were highly correlated in patients with a positive scintigraphy within the first 3 h. Eleven of the 20 correctly localized studies and none of the incorrectly localized studies were positive in the dynamic phase of imaging. In 5 patients (all erroneously localized), scintigraphy was positive only at a period longer than 18 h. RBC scintigraphy is an effective imaging modality in localizing lower gastrointestinal bleeding in patients for whom other diagnostic tests have failed to locate the bleeding. RBC scintigraphy can be successful in the detection of bleeding sites in the small intestine. Copyright © 2011 S. Karger AG, Basel.
Nakhjavani, Manouchehr; Abdollahi, Soraya; Farzanefar, Saeed; Abousaidi, Mohammadtagi; Esteghamati, Alireza; Naseri, Maryam; Eftekhari, Mohamad; Abbasi, Mehrshad
2017-04-02
Technetium thyroid uptake (TTU) is not inhibited by antithyroid drugs (ATD) and reflects the degree of thyroid stimulation. We intended to predict the relapse rate from hyperthyroidism based on TTU measurement. Out of 44 initially enrolled subjects, 38 patients aged 41.6 ± 14.6 with Graves disease (duration: 84 ± 78 months) completed the study. TTU was performed with 40-second imaging of the neck and mediastinum 20 minutes after injection of 1 mCi technetium-99m pertechnetate. TTU was measured as the percentage of the count of activity accumulated in the thyroidal region minus the mediastinal background uptake to the count of 1 mCi technetium-99m under the same acquisition conditions. Then methimazole was stopped and patients were followed. The optimal TTU cutoff value for Graves relapse prediction was calculated using Youden's J statistic. Hyperthyroidism relapsed in 11 (28.9%) patients 122 ± 96 (range: 15-290) days post-ATD withdrawal. The subjects in remission were followed for 209 ± 81 days (range: 88-390). TTU was significantly higher in patients with forthcoming relapse (12.0 ± 8.0 vs. 3.9 ± 2.0, P = .007). The difference was significant after adjustment for age, sex, history of previous relapse, disease duration, and thyroid-stimulating hormone (TSH) levels before withdrawal. The area under the receiver operative characteristic (ROC) curve was 0.87. The optimal TTU cutoff value for classification of subjects with relapse and remission was 8.7 with sensitivity, specificity, and positive and negative predictive value of 73%, 100%, 100%, and 90%, respectively (odds ratio [OR] = 10.0; 95% confidence interval [CI]: 3.4-29.3). TTU evaluation in hyperthyroid patients receiving antithyroid medication is an accurate and practical method for predicting relapse after ATD withdrawal. ATD = antithyroid drugs RIU = radio-iodine uptake TSH = thyroid-stimulating hormone TSI = thyroid-stimulating immunoglobulin TTU = technetium thyroid uptake.
Competitive Incorporation of Perrhenate and Nitrate into Sodalite
Dickson, Johnbull O.; Harsh, James B.; Flury, Markus; ...
2014-10-03
Nuclear waste storage tanks at the Hanford site in southeastern Washington have released highly alkaline solutions, containing radioactive and other contaminants, into subsurface sediments. When this waste reacts with subsurface sediments, feldspathoid minerals (sodalite, cancrinite) can form, sequestering pertechnetate ( 99TcO 4 –) and other ions. This study investigates the potential for incorporation of perrhenate (ReO 4 –), a chemical surrogate for 99TcO 4 –, into mixed perrhenate/nitrate (ReO 4 –/NO 3 –) sodalite. Mixed-anion sodalites were hydrothermally synthesized in the laboratory from zeolite A in sodium hydroxide, nitrate, and perrhenate solutions at 90 °C for 24 h. The resultingmore » solids were characterized by bulk chemical analysis, X-ray diffraction, scanning electron microscopy, and X-ray absorption near edge structure spectroscopy (XANES) to determine the products’ chemical composition, structure, morphology, and Re oxidation state. The XANES data indicated that nearly all rhenium (Re) was incorporated as Re(VII)O 4 –. The nonlinear increase of the unit cell parameter with ReO 4 –/NO 3 – ratios suggests formation of two separate sodalite phases in lieu of a mixed-anion sodalite. The results reveal that the sodalite cage is highly selective toward NO 3 – over ReO 4 –. Calculated enthalpy and Gibbs free energy of formation at 298 K for NO 3 - and ReO 4 -sodalite suggest that NO 3 – incorporation into the cage is favored over the incorporation of the larger ReO 4 –, due to the smaller ionic radius of NO 3 –. In conclusion, based on these results, it is expected that NO 3 –, which is present at significantly higher concentrations in alkaline waste solutions than 99TcO 4 –, will be strongly preferred for incorporation into the sodalite cage.« less
Proton pump inhibitors reduce the size and acidity of the acid pocket in the stomach.
Rohof, Wout O; Bennink, Roelof J; Boeckxstaens, Guy E
2014-07-01
The gastric acid pocket is believed to be the reservoir from which acid reflux events originate. Little is known about how changes in position, size, and acidity of the acid pocket contribute to the therapeutic effect of proton pump inhibitors (PPIs) in patients with gastroesophageal reflux disease (GERD). Thirty-six patients with GERD (18 not taking PPIs, 18 taking PPIs; 19 men; age, 55 ± 2.1 y) were analyzed by concurrent high-resolution manometry and pH-impedance monitoring after a standardized meal. The acid pocket was visualized using scintigraphy after intravenous administration of (99m)technetium-pertechnetate. The size of the acid pocket was measured and its position was determined, relative to the diaphragm, using radionuclide markers on a high-resolution manometry catheter. At the end of the study, the acid pocket was aspirated, and its pH level was measured. The number of reflux episodes was comparable between patients on and off PPIs, but the number of acid reflux episodes was reduced significantly in patients on PPIs. In patients on PPIs, the acid pocket was smaller and more frequently located below the diaphragm. The mean pH of the acid pocket was significantly lower in patients not taking PPIs (n = 6) than in those who were (n = 16) (0.9; range, 0.7-1.2 vs 4.0; range, 1.6-5.9; P < .001). The pH of acid pockets correlated significantly with the lowest pH values measured for refluxate (r = 0.72; P < .01). Based on analyses of acid pockets in patients with GERD, the acid pocket appears to be a reservoir from which reflux occurs when patients are receiving PPIs. PPIs might affect the size, acidity, or position of the acid pocket, which contributes to the efficacy in patients with GERD. Copyright © 2014 AGA Institute. Published by Elsevier Inc. All rights reserved.
Malhotra, Anshoo; Kumar, Pardeep; Sharma, Sarika; Dhawan, Davinder K
2010-01-01
The present study was designed to develop stable and economically competitive radioactive technetium-99m macro-aggregates of albumin ((99m)Tc-MAA) which could be used for imaging of lungs. Macro-aggregates were freshly prepared and labeled with (99m)Tc pertechnetate by following the standard protocol which included incubation of formulation at 80(o) C for 10 min. We studied 7 rats in every experiment. The rats were injected intravenously with (99m)Tc MAA and were sacrificed after 10 min to study its distribution in the lungs and other non target tissues using gamma ray spectrometer. This standard protocol was further experimented upon in order to achieve high target to non target ratio. Different formulations were prepared by incubating them at 80 degrees for different incubation times of 5, 10, 15, 20, 25 and 30 min. Formulation of MAA prepared by incubating at 80 degrees for 20 min labeled with (99m)Tc showed the highest target to non target ratio. Another group of rats that received the above formulation were sacrificed after two additional time intervals of 5 and 15 min. The target to non target ratio was high in animals sacrificed after 5 min of injecting them with (99m)Tc the MAA formulation prepared by heating at 80 degrees for 20 min as compared to animals sacrificed after 10 and 15 min. Formulations of MAA following storage at room temperatures which varied from 5(o)C to 18(o)C, for different time durations 1, 2 and 9 days were also evaluated for their ability to be reused after reheating and labeling with (99m)Tc. The formulation of MAA kept for 9 days showed the best target to non-target ratio. The present study suggests that MAA once prepared can be reused following labeling with (99m)Tc even after 9 days of storage with better target to non target ratio as compared to storage timer period of 1 and 2 days.
Iwata, Masahiro; Kasagi, Kanji; Hatabu, Hiroto; Misaki, Takashi; Iida, Yasuhiro; Fujita, Toru; Konishi, Junji
2002-06-01
This study was done retrospectively to analyze the ultrasonographic (US) findings in thyroid scintigraphic hot areas (HA). Three-thousand, eight-hundred and thirty-nine consecutive patients who underwent 99mTc-pertechnetate (n = 3435) or 123I (n = 457) scintigraphy were analyzed. HA were regarded as present when the tracer concentration was greater than the remaining thyroid tissue, or when hemilobar uptake was observed. High-resolution US examinations were performed with a real-time electronic linear scanner with a 7.5 or 10 MHz transducer. One hundred and four (2.7%) were found to be scintigraphic HA (n = 120). US revealed a nodular lesion or well-demarcated thyroid tissue corresponding to the HA in 94 areas (78.4%, Category 1), an ill-defined region with different echogenicity in 13 areas (10.8%, Category 2), and no correlating lesion in 13 areas (10.8%, Category 3). These 104 patients included 43 with adenomatous goiter (59 areas), 33 with adenoma, 11 with Hashimoto's thyroiditis, 5 with primary thyroid cancer, 4 with euthyroid ophthalmic Graves' disease (EOG), 3 with hemilobar atrophy or hypogenesis, 2 with hemilobar agenesis, 2 with hypothyroidism with blocking-type TSH-receptor antibodies (TSHRAb), I with acute suppurative thyroiditis. Among the 59 adenomatous nodules and 33 adenomas, 51 (86.4%) and 32 (97.0%), respectively, belonged to Category 1. A solitary toxic nodule was significantly larger and occurs more often in older patients than in younger patients. On the other hand, all 17 patients with known autoimmune thyroid diseases including Hashimoto's thyroiditis, EOG and hypothyroidism with blocking TSHRAb belonged to Category 2 or 3. Possible underlying mechanisms are 1) hyperfunctioning tumors or nodules, 2) localized functioning thyroid tissue freed from autoimmune destruction, inflammation or tumor invasion, 3) congenital abnormality, 4) clusters of hyperactive follicular cells caused by long-term TSH and/or TSHRAb stimulation, 5) asymmetry, etc. Scintigraphic HA are observed in patients with various thyroid diseases and high-resolution US appears to be helpful clinically for the differential diagnosis of the above mentioned disorders.
Son, Hye-Youn; Jeon, Yong-Hyun; Chung, June-Key; Kim, Chul-Woo
2016-12-01
In assessing the effectiveness of DNA vaccines, it is important to monitor: (1) the kinetics of target gene expression in vivo; and (2) the movement of cells that become transfected with the plasmid DNA used in the immunization of a subject. In this study, we used, as a visual imaging marker, expression of the transfected human sodium/iodide symporter (hNIS) gene, which enhances intracellular radio-pertechnetate (TcO4-) accumulation. After intradermal (i.d.) and systemic injection of mice with pcDNA-hNIS and radioactive Technetium-99m (Tc-99m), respectively, whole-body images were obtained by nuclear scintigraphy. The migration of mice cells transfected with the hNIS gene was monitored over a 2-week period by gamma-radioactivity counting of isolated cell populations and was demonstrated in peripheral lymphoid tissues, especially in the draining lymph nodes (dLNs). Beginning at 24 h after DNA inoculation and continuing for the 2-week monitoring period, hNIS-expressing cells were observed specifically in the T-cell-rich zones of the paracortical area of the dLNs. Over the same time period, high levels of INF-γ-secreting CD8 T-cells were found in the dLNs of the pcDNA-hNIS immunized mice. Tumor growth was also significantly retarded in the mice that received hNIS DNA immunization followed by inoculation with CT26 colorectal adenocarcinoma cells that had been transfected with the rat NIS gene (rNIS), which is 93% homologous to the hNIS gene. In conclusion, mouse cells transfected with hNIS DNA after i.d. immunization were found to traffic to the dLNs, and hNIS gene expression in these cells continued for at least 2 weeks post immunization. Furthermore, sequential presentation of NIS DNA to T-cells by migratory antigen presenting cells could induce NIS DNA-specific Th1 immune responses and thus retard the growth of NIS-expressing tumors. © The Author(s) 2016.
Adedapo, K S; Fadiji, I O; Orunmuyi, A T; Onimode, Y; Osifo, B O A
2012-12-01
Graves' disease is an autoimmune disorder characterized by hyperthyroidism and associated features. Management of this disease condition for many decades has been largely by surgical and medical intervention. Usage of anti thyroid medication ameliorates the symptoms and effects of excessive production of thyroid hormones. Recently in Nigeria, Nuclear medicine facility became available with the option radioiodine ablative therapy for the management of Graves disease. This study highlights the benefits of radioiodine therapy against the background of equally viable medical and surgical practice. PATIENTS MATERIAL AND METHOD: All the 36 patients seen from the inception of Nuclear Medicine facility at the University College Hospital from June 2006 to May 2010 were included in this study. Sources of referral were compiled. All the patients were on anti thyroid medication at presentation. Thyroid scan was performed by Siemens E- cam gamma camera 20 minutes after intravenous injection of 3-5 mCi of Tc-99m-Pertechnetate. The patients with "diffuse toxic goiter" on thyroid scan were given 10 mCi of Iodine-131 orally and discharged home with radiosafety precautions. Most of the patients were treated 5 days post discontinuation of antithyroid medication. The patients were followed-up monthly with thyroid function tests to determine commencement of replacement therapy. Peak incidence of Graves' disease was at 6th decade (38.9%) of all patients studied. This disease was commoner in women with a ratio of 8 to 1. Ten (27.8%) patients became hypothyroid at the 3rd month post radioactive iodine-131 treatment, while the remaining 20 (55.6%) patients became hypothyroid at the 5th month. Six patients were lost to follow up. There was no recurrence of hyperthyroidism in all patients treated. Twenty eight (93.3%) patients were maintained on 100 mcg of levo-thyroxine daily, while 2 (6.7%) patients had more than 100 mcg of levo- thyroxine daily as maintenance dose. Radioactive iodine therapy presents a safe and effective alternative to the older conventional mode of management of Graves' disease
NASA Astrophysics Data System (ADS)
Lee, Ji-Hoon; Zachara, John M.; Fredrickson, James K.; Heald, Steve M.; McKinley, James P.; Plymale, Andrew E.; Resch, Charles T.; Moore, Dean A.
2014-07-01
Redox-reactive, biogeochemical phases generated by reductive microbial activity in hyporheic zone sediments from a dynamic groundwater-river interaction zone were evaluated for their ability to reduce soluble pertechnetate [99Tc(VII)O4-] to less soluble Tc(IV). The sediments were bioreduced by indigenous microorganisms that were stimulated by organic substrate addition in synthetic groundwater with or without sulfate. In most treatments, 20 μmol L-1 initial aqueous Tc(VII) was reduced to near or below detection (3.82 × 10-9 mol L-1) over periods of days to months in suspensions of variable solids concentrations. Native sediments containing significant lithogenic Fe(II) in various phases were, in contrast, unreactive with Tc(VII). The reduction rates in the bioreduced sediments increased with increases in sediment mass, in proportion to weak acid-extractable Fe(II) and sediment-associated sulfide (AVS). The rate of Tc(VII) reduction was first order with respect to both aqueous Tc(VII) concentration and sediment mass, but correlations between specific reductant concentrations and reaction rate were not found. X-ray microprobe measurements revealed a strong correlation between Tc hot spots and Fe-containing mineral particles in the sediment. However, only a portion of Fe-containing particles were Tc-hosts. The Tc-hot spots displayed a chemical signature (by EDXRF) similar to pyroxene. The application of autoradiography and electron microprobe allowed further isolation of Tc-containing particles that were invariably found to be ca 100 μm aggregates of primary mineral material embedded within a fine-grained phyllosilicate matrix. EXAFS spectroscopy revealed that the Tc(IV) within these were a combination of a Tc(IV)O2-like phase and Tc(IV)-Fe surface clusters, with a significant fraction of a TcSx-like phase in sediments incubated with SO42-. AVS was implicated as a more selective reductant at low solids concentration even though its concentration was below that required for stoichiometric reduction of Tc(VII). These results demonstrate that composite mineral aggregates may be redox reaction centers in coarse-textured hyporheic zone sediments regardless of the dominant anoxic biogeochemical processes.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Muenter, Marc W.; Hoffner, Simone; Department of Nuclear Medicine, University of Heidelberg, Heidelberg
2007-03-01
Purpose: The aim of this study was to compare changes in salivary gland function after intensity-modulated radiotherapy (IMRT) and conventional radiotherapy (RT), with or without Amifostine, for tumors of the head-and-neck region using quantitative salivary gland scintigraphy (QSGS). Methods and Materials: A total of 75 patients received pre- and post-therapeutic QSGS to quantify the salivary gland function. In all, 251 salivary glands were independently evaluated. Changes in the maximum uptake ({delta}U) and relative excretion rate ({delta}F) both pre- and post-RT were determined to characterize radiation-induced changes in the salivary gland function. In addition, dose-response curves were calculated. Results: In allmore » groups, maximum uptake and relative excretion rate were reduced after RT ({delta}U {<=}0 and {delta}F {<=}0). The reduction was significantly lower for IMRT than for conventional RT. For the parotid glands, the reduction was smaller for the IMRT-low than for the IMRT-high group. For the Amifostine-high and the conventional group the difference was significant only for one parameter ({delta}U, parotid and submandibular glands, p < 0.05). In contrast to this, the difference between the Amifostine-low and the conventional group was always significant or at least showed a clear trend for both changes in U and F. In regard to the endpoint 'reduction of the salivary gland excretion rate of more than 50%,' the dose-response curves yielded D{sub 50}-values of 34.2 {+-} 12.2 Gy for the conventionally treated group and 36.8 {+-} 2.9 Gy for the IMRT group. For the Amifostine group, an increased D{sub 50}-values of 46.3 {+-} 2.3 Gy was obtained. Conclusion: Intensity-modulated RT can significantly reduce the loss of parotid gland function when respecting a certain dose threshold. Conventional RT plus Amifostine prevents reduced salivary gland function only in the patient group treated with <40.6 Gy.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lee, Ji-Hoon; Zachara, John M.; Fredrickson, Jim K.
Redox-reactive, biogeochemical phases generated by reductive microbial activity in hyporheic zone sediments from a dynamic groundwater-river interaction zone were evaluated for their ability to reduce soluble pertechnetate [99Tc(VII)O4-] to less soluble Tc(IV). The sediments were bioreduced by indigenous microorganisms that were stimulated by organic substrate addition in synthetic groundwater with or without sulfate. In most treatments, 20 µmol L-1 initial aqueous Tc(VII) was reduced to near or below detection (3.82×10-9 mol L-1) over periods of days to months in suspensions of variable solids concentrations. Native sediments containing significant lithogenic Fe(II) in various phases were, in contrast, unreactive with Tc(VII). Themore » reduction rates in the bioreduced sediments increased with increases in sediment mass, in proportion to weak acid-extractable Fe(II) and sediment-associated sulfide (AVS). The rate of Tc(VII) reduction was first order with respect to both aqueous Tc(VII) concentration and sediment mass, but correlations between specific reductant concentrations and reaction rate were not found. X-ray microprobe measurements revealed a strong correlation between Tc hot spots and Fe-containing mineral particles in the sediment. However, only a portion of Fe-containing particles were Tc-hosts. The Tc-hot spots displayed a chemical signature (by EDXRF) similar to pyroxene. The application of autoradiography and electron microprobe allowed further isolation of Tc-containing particles that were invariably found to be ca 100 µm aggregates of primary mineral material embedded within a fine-grained phyllosilicate matrix. EXAFS spectroscopy revealed that the Tc(IV) within these were a combination of a Tc(IV)O2-like phase and Tc(IV)-Fe surface clusters, with a significant fraction of a TcSx-like phase in sediments incubated with SO42-. AVS was implicated as a more selective reductant at low solids concentration even though its concentration was below that required for stoichiometric reduction of Tc(VII). These results demonstrate that composite mineral aggregates may be redox reaction centers in coarse-textured hyporheic zone sediments regardless of the dominant anoxic biogeochemical processes.« less
Vandehey, Nicholas T; O'Neil, James P; Slowey, Aaron J; Boutchko, Rostyslav; Druhan, Jennifer L; Moses, William W; Nico, Peter S
2012-11-20
We demonstrate the utility of nuclear medical imaging technologies and a readily available radiotracer, [(99m)Tc]TcO(4)(-), for the noninvasive monitoring of Fe(II) production in acetate-stimulated sediments from Old Rifle, CO, USA. Microcosms consisting of sediment in artificial groundwater media amended with acetate were probed by repeated injection of radiotracer over three weeks. Gamma camera imaging was used to noninvasively quantify the rate and extent of [(99m)Tc]TcO(4)(-) partitioning from solution to sediment. Aqueous Fe(II) and sediment-associated Fe(II) were also measured and correlated with the observed tracer behavior. For each injection of tracer, curves of (99m)Tc concentration in solution vs time were fitted to an analytic function that accounts for both the observed rate of sedimentation as well as the rate of (99m)Tc association with the sediment. The rate and extent of (99m)Tc association with the biostimulated sediment correlated well with the production of Fe(II), and a mechanism of [(99m)Tc]TcO(4)(-) reduction via reaction with surface-bound Fe(II) to form an immobile Tc(IV) species was inferred. After three weeks of bioreduction, a subset of microcosms was aerated in order to reoxidize the Fe(II) to Fe(III), which also destroyed the affinity of the [(99m)Tc]TcO(4)(-) for the sediments. However, within 3 days postoxidation, the rate of Tc(VII) reduction was faster than immediately before oxidation implying a rapid return to more extensive bioreduction. Furthermore, aeration soon after a tracer injection showed that sediment-bound Tc(IV) is rapidly resolubilized to Tc(VII). In contrast to the [(99m)Tc]TcO(4)(-), a second commercially available tracer, (99m)Tc-DTPA (diethylenetriaminepentaacetic acid), had minimal association with sediment in both controls and biostimulated sediments. These experiments show the promise of [(99m)Tc]TcO(4)(-) and (99m)Tc-DTPA as noninvasive imaging probes for a redox-sensitive radiotracer and a conservative flow tracer, respectively.
Senthilkumar, B; Sathasivasubramanian, S
2013-09-01
The aim of the present study was to evaluate the salivary gland dysfunction in patients with uncontrolled type II diabetes using salivary gland scintigraphy and then to compare these ratios with quantitative whole salivary secretion rates. Using a gamma camera (siemens-diacam) equipped with a low energy all-purpose collimator, 32 uncontrolled type II diabetic patients and 30 normal healthy patients were studied by injecting a radio isotope (technetium 99m pertechnetate) about 5 mCi was injected intravenously in to anticubital vein and the activity was measured for the 1(st), 20(th) and 40(th) min. At 20 min after injection, vitamin C chewable tablet was given to stimulate the secretion and continued until the end of the study period (40 min). Before scintigraphy, salivary sampling was carried out in both diabetic and normal individuals in a quiet room, saliva was allowed to accumulate and was expectorated into the collecting vessel approximately once a minute for 15 min and the volume was recorded as Unstimulated salivary flow rate and after 5 min break vitamin C chewable tablet was given to stimulate the secretion and the patient was asked to expectorate the saliva in the collecting vessel for 5 min. The expectorated volume was recorded as stimulated salivary flow rate. The mean of the measurements of scintigraphic ratio and salivary secretion rates were compared using the paired Student's t-test. The scintigraphic mean uptake and excretory ratio (ER) and the salivary flow rates were correlated. The result shows that there was a significant correlation between salivary flow rate and scintigraphic uptake and ER. However, statistically significant result could not be derived as it may be due to smaller sample size and marginal difference in the scintigraphic values between the groups. Salivary gland scintigraphy plays a significant role in the evaluation of salivary gland dysfunction. However, its role as an independent investigative procedure in the evaluation of salivary gland dysfunction requires a study with a larger sample size, may yield a statistical significant result and it can also act as an adjunct along with salivary flow rate procedure.
Sabah, Khandker Mohammad Nurus; Chowdhury, Abdul Wadud; Islam, Mohammad Shahidul; Cader, Fathima Aaysha; Kawser, Shamima; Hosen, Md Imam; Saleh, Mohammed Abaye Deen; Alam, Md Shariful; Chowdhury, Mohammad Monjurul Kader; Tabassum, Humayara
2014-11-18
Graves' disease, a well-known cause of hyperthyroidism, is an autoimmune disease with multi-system involvement. More prevalent among young women, it appears as an uncommon cardiovascular complication during pregnancy, posing a diagnostic challenge, largely owing to difficulty in detecting the complication, as a result of a low index of suspicion of Graves' disease presenting during pregnancy. Globally, cardiovascular disease is an important factor for pregnancy-related morbidity and mortality. Here, we report a case of Graves' disease detected for the first time in pregnancy, in a patient presenting with bi- ventricular heart failure, severe pulmonary hypertension and pre- eclampsia. Emphasis is placed on the spectrum of clinical presentations of Graves' disease, and the importance of considering this thyroid disorder as a possible aetiological factor for such a presentation in pregnancy. A 30-year-old Bangladeshi-Bengali woman, in her 28th week of pregnancy presented with severe systemic hypertension, bi-ventricular heart failure and severe pulmonary hypertension with a moderately enlarged thyroid gland. She improved following the administration of high dose intravenous diuretics, and delivered a premature female baby of low birth weight per vaginally, twenty four hours later. Pre-eclampsia was diagnosed on the basis of hypertension first detected in the third trimester, 3+ oedema and mild proteinuria. Electrocardiography revealed sinus tachycardia with incomplete right bundle branch block and echocardiography showed severe pulmonary hypertension with an estimated pulmonary arterial systolic pressure of 73 mm Hg, septal and anterior wall hypokinesia with an ejection fraction of 51%, grade I mitral and tricuspid regurgitation. Thyroid function tests revealed a biochemically hyperthyroid state and positive anti- thyroid peroxidase antibodies was found. (99m)Technetium pertechnetate thyroid scans demonstrated diffuse toxic goiter as evidenced by an enlarged thyroid gland with intense radiotracer concentration all over the gland. The clinical and biochemical findings confirmed the diagnosis of Graves' disease. Graves' disease is an uncommon cause of bi-ventricular heart failure and severe pulmonary hypertension in pregnancy, and a high index of clinical suspicion is paramount to its effective diagnosis and treatment.
[⁹⁹mTc]O₂-AMD3100 as a SPECT tracer for CXCR4 receptor imaging.
Hartimath, Siddesh V; Domanska, Urszula M; Walenkamp, Annemiek M E; Rudi A J O, Dierckx; de Vries, Erik F J
2013-05-01
CXCR4 plays an important role in HIV infection, tumor progression, neurogenesis, and inflammation. In-vivo imaging of CXCR4 could provide more insight in the role of this receptor in health and disease. The aim of this study was to investigate [(99m)Tc]O₂-AMD3100 as a potential SPECT tracer for imaging of CXCR4. AMD3100 was labelled with [(99m)Tc]pertechnetate. A cysteine challenge assay was performed to test the tracer stability. Heterologous and homologous receptor binding assay and internalization assay were performed in CXCR4 expressing Jurkat-T cells. Ex vivo biodistribution was studied in healthy mice at 30, 60, and 120 min after tracer injection. Tumor uptake of the tracer was determined by microSPECT imaging in nude mice xenografted with human PC-3 prostate tumor. Specificity of tracer uptake was determined by blocking studies using an excess of unlabelled AMD3100. AMD3100 was labelled with technetium-99m with a radiochemical yield of >98%. The tracer was stable in PBS and mouse plasma for at least 6h at 37 °C. Heterologous and homologous binding assays with AMD3100 showed IC50 values of 240 ± 10 μM, and 92 ± 5 μM for [(125)I]SDF-1α and [(99m)Tc]O₂-AMD3100 respectively, with negligible receptor internalisation. The tracer showed high uptake in liver, lungs, spleen, thymus, intestine and bone. Blocking dose of AMD3100.8HCl (20mg/kg) decreased the uptake in these organs (p<0.05). [(99m)Tc]O2-AMD3100 showed specific tumor accumulation in mice bearing PC-3 xenografts model. Time activity curves (TAC) in AMD3100 pre-treated animals tracer showed 1.7 times less tumor uptake as compared to control animals (p<0.05). [(99m)Tc]O2-AMD3100 is readily labelled, is stable in plasma and displays a favourable binding affinity for the CXCR4 receptors. [(99m)Tc O₂-AMD3100 shows specific binding in organs with high CXCR4 expression and in CXCR4 positive tumors. These results justify further evaluation of this radiopharmaceutical as a potential biomarker for the non-invasive imaging of CXCR4 receptors. Copyright © 2013 Elsevier Inc. All rights reserved.
Boschi, Alessandra; Massi, Alessandro; Uccelli, Licia; Pasquali, Micol; Duatti, Adriano
2010-11-01
A novel nitrido nitrogen atom donor for the preparation of (99m)Tc and (188)Re radiopharmaceuticals containing a metal-nitrogen multiple bond is presented. HO(2)C-PEG(600)-DTCZ was obtained by conjugation of N-methyl-S-methyl dithiocarbazate [H(2)N-N(CH(3))-C(S)SCH(3), HDTCZ] with polyethylene glycol 600 (PEG(600)). Asymmetrical heterocomplexes of the type [M(N)(PNP)(B)](0/+) (M=(99m)Tc, (188)Re; PNP=diphosphine ligands, B=DBODC, DEDC, NSH, H(2)OS, CysNAc, HDTCZ) and symmetrical nitride compounds of the type [M(N)(L)(2)] (L=DEDC, DPDC) have been prepared in high yield by using the newly designed nitride nitrogen atom donor HO(2)C-PEG(600)-DTCZ. A two-step procedure was applied for preparing the above symmetrical and asymmetrical complexes. The first step involved the preliminary formation of a mixture of nitride Tc-99m or Re-188 precursors, which contained the [M≡N](2+) core, through reduction of generator-eluted (99m)Tc-pertechnetate or (188)Re-perrhenate with thin (II) chloride in the presence of HO(2)C-PEG(600)-DTCZ. In the second step, the intermediate mixture was converted either in the final mixed asymmetrical complex by the simultaneous addition of diphosphine ligand and the suitable bidentate ligand B, or in the final symmetrical complex by the only addition of the bidentate ligand L. It was also demonstrated that the novel water-soluble nitride nitrogen atom donor HO(2)C-PEG(600)-DTCZ did not show coordinating properties toward the M≡N ((99m)Tc, (188)Re) core. Biodistribution studies in rats of the hitherto unreported [(99m)Tc(N)(PNP(3))DTCZ](+) and [(99m)Tc(N)(PNP(5))DTCZ](+) complexes showed that they selectively localize in the myocardium of rats with a favourable heart-to-lung and heart-to-liver uptake ratios. In particular, the heart-to-lung and heart-to-liver uptake ratios dramatically increased in the interval between 60 and 120 min postinjection. Hence, the combination of the favourable chemical and biological properties of HO(2)C-PEG(600)-DTCZ might confer to this novel compound an important role for the development of new (99m)Tc and (188)Re-nitrido radiopharmaceuticals. Copyright © 2010 Elsevier Inc. All rights reserved.
Radiation dose to technologists per nuclear medicine examination and estimation of annual dose.
Bayram, Tuncay; Yilmaz, A Hakan; Demir, Mustafa; Sonmez, Bircan
2011-03-01
Conventional diagnostic nuclear medicine applications have been continuously increasing in most nuclear medicine departments in Turkey, but to our knowledge no one has studied the doses to technologists who perform nuclear medicine procedures. Most nuclear medicine laboratories do not have separate control rooms for technologists, who are quite close to the patient during data acquisition. Technologists must therefore stay behind lead shields while performing their task if they are to reduce the radiation dose received. The aim of this study was to determine external radiation doses to technologists during nuclear medicine procedures with and without a lead shield. Another aim was to investigate the occupational annual external radiation doses to Turkish technologists. This study used a Geiger-Müller detector to measure dose rates to technologists at various distances from patients (0.25, 0.50, 1, and 2 m and behind a lead shield) and determined the average time spent by technologists at these distances. Deep-dose equivalents to technologists were obtained. The following conventional nuclear medicine procedures were considered: thyroid scintigraphy performed using (99m)Tc pertechnetate, whole-body bone scanning performed using (99m)Tc-methylene diphosphonate, myocardial perfusion scanning performed using (99m)Tc-methoxyisobutyl isonitrile, and (201)Tl (thallous chloride) and renal scanning performed using (99m)Tc-dimercaptosuccinic acid. The measured deep-dose equivalent to technologists per procedure was within the range of 0.13 ± 0.05 to 0.43 ± 0.17 μSv using a lead shield and 0.21 ± 0.07 to 1.01 ± 0.46 μSv without a lead shield. Also, the annual individual dose to a technologist performing only a particular scintigraphic procedure throughout a year was estimated. For a total of 95 clinical cases (71 patients), effective external radiation doses to technologists were found to be within the permissible levels. This study showed that a 2-mm lead shield markedly reduced the external dose to technologists. The doses to technologists varied significantly for different diagnostic applications. Consequently, the estimated annual dose to a technologist performing only a particular scintigraphic procedure is very different from one type of procedure to another. The results of this study should help in determining the rotation time of technologists in different procedures and differences in their individual techniques.
Laube, Beth L; Sharpless, Gail; Vikani, Ami R; Harrand, Vincent; Zinreich, Simeon J; Sedberry, Keith; Knaus, Darin; Barry, James; Papania, Mark
2015-10-01
To our knowledge, quantification of intranasal deposition of aerosol generated by Accuspray(™) (AS) in children has never been published. We hypothesized that deposition would vary significantly with age and with placement of the device within, or outside, of the nostril. We tested these hypotheses in anatomically-correct physical models based on CT scans of 2-, 5-, and 12-year-old children with normal, intranasal airways. Models included a removable anterior nose (AN) with exterior facial features and interior nasal vestibule and nasal valve area and a main nasal airway (MNA), subdivided into upper (superior turbinates and olfactory area), middle (middle turbinates), and lower (inferior turbinates and nasopharynx) thirds. Aerosol was generated from distilled water admixed with (99m)technetium pertechnetate and administered during static airflow by AS inserted inside the right nostril (eight runs/model), or outside the right nostril (six runs/model). Mean aerosol Dv(50) ± standard deviation was 67.8 ± 24.7 μm. Deposition was quantified by 2D gamma scintigraphy and expressed as percentage of the emitted dose. When placed inside the nostril, mean (± standard deviation) deposition within the MNA was significantly less in the 2-year-old, compared to the 5- and 12-year-old, averaging 46.8 ± 33.8% (AN:55.4 ± 29.9%), 75.4 ± 26.7% (AN:23.3 ± 13.6%), and 72.1 ± 18.5% (AN:25.8 ± 18.5%), respectively (p<0.05). When placed outside the nostril, MNA was significantly less in the 2- and 5-year-old compared to the 12-year-old, with 1.4 ± 2.5% (AN:69.7 ± 40.7%), 7.4 ± 9.0% (AN:77.8 ± 32.8%), and 21.1 ± 29.1% (AN:29.2 ± 19.3%), respectively (p<0.05). Deposition in the MNA of all age models was highest when AS was placed inside the nostril (p<0.05). Deposition in the lower third was significantly increased for the 5- and 12-year-old and in the middle third of the 5-year-old when AS was placed inside the nostril. These results indicate that age and device placement play important roles in terms of intranasal deposition, when administering aerosol with Accuspray(™) to children.
New software for raw data mask processing increases diagnostic ability of myocardial SPECT imaging.
Tanaka, Ryo; Yoshioka, Katsunori; Seino, Kazue; Ohba, Muneo; Nakamura, Tomoharu; Shimada, Katsuhiko
2011-05-01
Increased activity of myocardial perfusion tracer technetium-99m in liver and hepatobiliary system causes streak artifacts, which may affect clinical diagnosis. We developed a mask-processing tool for raw data generated using technetium-99m as a myocardial perfusion tracer. Here, we describe improvements in image quality under the influence of artifacts caused by high accumulation in other organs. A heart phantom (RH-2) containing 15 MBq of pertechnetate was defined as model A. Model B was designed in the same phantom containing ten times of cardiac radioactivity overlapping with other organs. Variance in the vertical profile count in the lower part of the myocardial inferior wall and in the myocardial circumferential profile curve were investigated in a phantom and clinical cases using our raw data masking (RDM) software. The profile variances at lower parts of myocardial inferior walls were 965.43 in model A, 1390.11 in model B and 815.85 in B-RDM. The mean ± SD of myocardial circumferential profile curves were 83.91 ± 7.39 in model A, 69.61 ± 11.45 in model B and 82.68 ± 9.71 in model B-RDM. For 11 clinical images with streak artifacts, the average of the variance significantly differed between with and without RDM (3.95 vs. 21.05; P < 0.05). For 50 clinical images with hepatic accumulation artifacts, the average of the variance on vertical profiles on images with and without RDM significantly differed (5.99 vs. 15.59; P < 0.01). Furthermore, when a segment with <60% uptake in polar maps was defined as abnormal, the average extent score of 1 h (Tc-1h), 5 min of RDM (Tc-0h-RDM) and 5 min of non-RDM (Tc-0h-non-RDM) were 2.25 ± 3.12, 2.35 ± 3.16, and 1.37 ± 2.41, respectively. Differences were significant between Tc-1h and Tc-0h-non-RDM (P < 0.005) but not between Tc-1h and Tc-0h-RDM. Batch processing was enabled in all frames by shifting the myocardium to the center of rotation using this software. The waiting time between infusion and image acquisition should be decreased, thus reducing patient burden and improving the diagnostic ability of the procedure.
Brandt, Michael P.; Kloos, Richard T.; Shen, Daniel H.; Zhang, Xiaoli; Liu, Yu-Yu
2012-01-01
Background Micro–single-photon emission computed tomography (SPECT) provides a noninvasive way to evaluate the effects of genetic and/or pharmacological modulation on sodium-iodide symporter (NIS)–mediated radionuclide accumulation in mouse thyroid and salivary glands. However, parameters affecting image acquisition and analysis of mouse thyroids and salivary glands have not been thoroughly investigated. In this study, we investigated the effects of region-of-interest (ROI) selection, collimation, scan time, and imaging orbit on image acquisition and quantification of thyroidal and salivary radionuclide accumulation in mice. Methods The effects of data window minima and maxima on thyroidal and salivary ROI selection using a visual boundary method were examined in SPECT images acquired from mice injected with 123I NaI. The effects of collimation, scan time, and imaging orbit on counting linearity and signal intensity were investigated using phantoms filled with various activities of 123I NaI or Tc-99m pertechnetate. Spatial resolution of target organs in whole-animal images was compared between circular orbit with parallel-hole collimation and spiral orbit with five-pinhole collimation. Lastly, the inter-experimental variability of the same mouse scanned multiple times was compared with the intra-experimental variability among different mice scanned at the same time. Results Thyroid ROI was separated from salivary glands by empirically increasing the data window maxima. Counting linearity within the range of 0.5–14.2 μCi was validated by phantom imaging using single- or multiple-pinhole collimators with circular or spiral imaging orbit. Scanning time could be shortened to 15 minutes per mouse without compromising counting linearity despite proportionally decreased signal intensity. Whole-animal imaging using a spiral orbit with five-pinhole collimators achieved a high spatial resolution and counting linearity. Finally, the extent of inter-experimental variability of NIS-mediated radionuclide accumulation in the thyroid and salivary glands by SPECT imaging in the same mouse was less than the magnitude of variability among the littermates. Conclusions The impacts of multiple variables and experimental designs on micro-SPECT imaging and quantification of radionuclide accumulation in mouse thyroid and salivary glands can be minimized. This platform will serve as an invaluable tool to screen for pharmacologic reagents that differentially modulate thyroidal and salivary radioiodine accumulation in preclinical mouse models. PMID:22540327
Clinical translation of a PSMA inhibitor for 99mTc-based SPECT.
Ferro-Flores, Guillermina; Luna-Gutiérrez, Myrna; Ocampo-García, Blanca; Santos-Cuevas, Clara; Azorín-Vega, Erika; Jiménez-Mancilla, Nallely; Orocio-Rodríguez, Emmanuel; Davanzo, Jenny; García-Pérez, Francisco O
2017-05-01
Prostate-specific membrane antigen (PSMA) is highly over-expressed in advanced prostate cancers. 68 Ga-labeled PSMA inhibitors (iPSMA) are currently used for prostate cancer detection by PET imaging. The availability of simple, efficient and reproducible radiolabeling procedures is essential for developing new SPECT radiopharmaceuticals for clinical translation. The aim of this research was to prepare 99m Tc-EDDA/HYNIC-Lys(Nal)-Urea-Glu ( 99m Tc-EDDA/HYNIC-iPSMA) obtained from lyophilized kit formulations and evaluate the in vitro and in vivo radiopharmaceutical binding to prostate cancer cells over-expressing PSMA, as well as the 99m Tc-EDDA/HYNIC-iPSMA normal biodistribution in humans and the preliminary uptake in patients with prostate cancer. 99m Tc labeling was performed by adding sodium pertechnetate solution and a 0.2M phosphate buffer (pH 7.0) to a lyophilized formulation containing HYNIC-iPSMA, EDDA, tricine, mannitol and stannous chloride. The radiochemical purity was evaluated by reversed-phase HPLC and ITLC-SG analyses. Stability studies in human serum were performed by size-exclusion HPLC. In vitro cell uptake was tested using prostate cancer cells (LNCaP) with blocked and non-blocked receptors. Biodistribution and tumor uptake were determined in LNCaP tumor-bearing nude mice with blocked and non-blocked receptors, and images were obtained using a micro-SPECT/CT. Whole-body images from three healthy men and two patients with histologically-confirmed prostate cancer (one of them with a previous 68 Ga-PSMA-617scan) were acquired at 1h and 3h after 99m Tc-EDDA/HYNIC-iPSMA administration with radiochemical purities of >98%. In vitro and in vivo studies showed high radiopharmaceutical stability in human serum, specific recognition for PSMA, high tumor uptake (10.22±2.96% ID/g at 1h) with rapid blood clearance and mainly kidney elimination. Preliminary images in patients demonstrated the ability of 99m Tc-EDDA/HYNIC-iPSMA to detect tumors and metastases of prostate cancer as well as 68 Ga-PSMA-617 does. The results obtained in this study warrant further dosimetry and clinical studies to determine the specificity and sensitivity of 99m Tc-EDDA/HYNIC-iPSMA. Copyright © 2017 Elsevier Inc. All rights reserved.
Technetium-99 cycling in maple trees: characterization of changes in chemical form.
Garten, C T; Lomax, R D
1989-08-01
Prior field studies near an old radioactive waste disposal site at Oak Ridge, TN, indicated that following root uptake, metabolism by deciduous trees rendered 99Tc less biogeochemically mobile than expected, based on chemistry of the pertechnetate (TcO-4) anion. Subsequently, the form of technetium (Tc) in maple tree (Acer sp.) sap, leaves, wood and forest leaf litter was characterized using one or more of the following methods: dialysis, physical fractionation, chemical extraction, gel permeation chromatography, enzymatic extraction, or thin layer chromatography (TLC) on silica gel. Chromatography (Sephadex G-25) of TcO-4 incubated in vitro with tree sap showed it to behave similar to TcO-4 anion. When labeled wood and leaf tissues were processed using a tissue homogenizer, 15% and 40%, respectively, of the Tc was solubilized into phosphate buffer. Most (65% to 80%) of the solubilized Tc passing a 0.45-micron filter also passed through an ultrafiltration membrane with a nominal molecular weight cutoff of 10,000 atomic mass units (amu). A majority (72% to 80%) of the Tc in wood could be chemically removed by successive extractions with ethanol, water and weak mineral acid. These same extractants removed only 23% to 31% of the Tc from maple leaves or forest floor leaf litter. Most of the Tc in leaves and leaf litter was removed only by strongly alkaline reagents typically used to release structural polysaccharides (hemicelluloses) from plant tissues. Chromatography (Sephadex G-25) of the ethanol-water extract from wood and the alkaline extract from leaves demonstrated that Tc in these extracts was not principally TcO-4 but was complexed with molecules greater than 1000 amu. Incubations of leaf and wood homogenates with protease approximately doubled the amount of Tc released from contaminated tissues. Ultrafiltration of protease-solubilized Tc from leaves and wood showed that 40% and 93%, respectively, of the Tc was less than 10,000 amu. TLC of the less than 10,000 amu fraction indicated the presence of TcO-4 in wood but not in leaves. In the leaf, TcO-4 is converted to less soluble forms apparently associated with structural components of leaf cell walls. This conversion explains why 99Tc is not easily leached by rainfall from tree foliage and why 99Tc appears to accumulate in forest floor leaf litter layers at the Oak Ridge study site.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pierce, Eric M.; Lukens, Wayne W.; Fitts, Jeff. P.
2013-12-01
A key component to closing the nuclear fuel cycle is the storage and disposition of nuclear waste in geologic systems. Multiphase ceramic waste forms have been studied extensively as a potential host matrix for nuclear waste. Understanding the speciation, partitioning, and release behavior of radionuclides immobilized in multiphase ceramic waste forms is a critical aspect of developing the scientific and technical basis for nuclear waste management. In this study, we evaluated a sodalite-bearing multiphase ceramic waste form (i.e., fluidized-bed steam reform sodium aluminosilicate [FBSR NAS] product) as a potential host matrix for long-lived radionuclides, such as technetium (99Tc). The FBSRmore » NAS material consists primarily of nepheline (ideally NaAlSiO4), anion-bearing sodalites (ideally M8[Al6Si6O24]X2, where M refers to alkali and alkaline earth cations and X refers to monovalent anions), and nosean (ideally Na8[AlSiO4]6SO4). Bulk X-ray absorption fine structure analysis of the multiphase ceramic waste form, suggest rhenium (Re) is in the Re(VII) oxidation state and has partitioned to a Re-bearing sodalite phase (most likely a perrhenate sodalite Na8[Al6Si6O24](ReO4)2). Rhenium was added as a chemical surrogate for 99Tc during the FBSR NAS synthesis process. The weathering behavior of the FBSR NAS material was evaluated under hydraulically unsaturated conditions with deionized water at 90 ?C. The steady-state Al, Na, and Si concentrations suggests the weathering mechanisms are consistent with what has been observed for other aluminosilicate minerals and include a combination of ion exchange, network hydrolysis, and the formation of an enriched-silica surface layer or phase. The steady-state S and Re concentrations are within an order of magnitude of the nosean and perrhenate sodalite solubility, respectively. The order of magnitude difference between the observed and predicted concentration for Re and S may be associated with the fact that the anion-bearing sodalites contained in the multiphase ceramic matrix are present as mixed-anion sodalite phases. These results suggest the multiphase FBSR NAS material may be a viable host matrix for long-lived, highly mobilie radionuclides which is a critical aspect in the management of nuclear waste.« less
Imaging of the thyroid in benign and malignant disease.
Intenzo, Charles M; Dam, Hung Q; Manzone, Timothy A; Kim, Sung M
2012-01-01
The thyroid gland was one of the first organs imaged in nuclear medicine, beginning in the 1940s. Thyroid scintigraphy is based on a specific phase or prelude to thyroid hormone synthesis, namely trapping of iodide or iodide analogues (ie, Tc99m pertechnetate), and in the case of radioactive iodine, eventual incorporation into thyroid hormone synthesis within the thyroid follicle. Moreover, thyroid scintigraphy is a reflection of the functional state of the gland, as well as the physiological state of any structure (ie, nodule) within the gland. Scintigraphy, therefore, provides information that anatomical imaging (ie, ultrasound, computed tomography [CT], magnetic resonance imaging) lacks. Thyroid scintigraphy plays an essential role in the management of patients with benign or malignant thyroid disease. In the former, the structure or architecture of the gland is best demonstrated by anatomical or cross-sectional imaging, such as ultrasound, CT, or even magnetic resonance imaging. The role of scintigraphy, however, is to display the functional state of the thyroid gland or that of a clinically palpable nodule within the gland. Such information is most useful in (1) patients with thyrotoxicosis, and (2) those patients whose thyroid nodules would not require tissue sampling if their nodules are hyperfunctioning. In neoplastic thyroid disease, thyroid scintigraphy is often standard of care for postthyroidectomy remnant evaluation and in subsequent thyroid cancer surveillance. Planar radioiodine imaging, in the form of the whole-body scan (WBS) and posttherapy scan (PTS), is a fundamental tool in differentiated thyroid cancer management. Continued controversy remains over the utility of WBS in a variety of patient risk groups and clinical scenarios. Proponents on both sides of the arguments compare WBS with PTS, thyroglobulin, and other imaging modalities with differing results. The paucity of large, randomized, prospective studies results in dependence on consensus expert opinion and retrospective analysis with inherent bias. With a growing trend not to ablate low-risk patients, so that a PTS cannot be performed, some thyroid carcinoma patients may never have radioiodine imaging. In routine clinical practice, however, imaging plays a critical role in patient management both before and after treatment. Moreover, as evidenced by the robust flow of publications concerning WBS and PTS, planar imaging of thyroid carcinoma remains a topic of great interest in this modern age of rapidly advancing cross sectional and hybrid imaging with single-photon emission computed tomography, single-photon emission computed tomography/CT, and positron emission tomography/CT. Copyright © 2012. Published by Elsevier Inc.
Performance of 3DOSEM and MAP algorithms for reconstructing low count SPECT acquisitions.
Grootjans, Willem; Meeuwis, Antoi P W; Slump, Cornelis H; de Geus-Oei, Lioe-Fee; Gotthardt, Martin; Visser, Eric P
2016-12-01
Low count single photon emission computed tomography (SPECT) is becoming more important in view of whole body SPECT and reduction of radiation dose. In this study, we investigated the performance of several 3D ordered subset expectation maximization (3DOSEM) and maximum a posteriori (MAP) algorithms for reconstructing low count SPECT images. Phantom experiments were conducted using the National Electrical Manufacturers Association (NEMA) NU2 image quality (IQ) phantom. The background compartment of the phantom was filled with varying concentrations of pertechnetate and indiumchloride, simulating various clinical imaging conditions. Images were acquired using a hybrid SPECT/CT scanner and reconstructed with 3DOSEM and MAP reconstruction algorithms implemented in Siemens Syngo MI.SPECT (Flash3D) and Hermes Hybrid Recon Oncology (Hyrid Recon 3DOSEM and MAP). Image analysis was performed by calculating the contrast recovery coefficient (CRC),percentage background variability (N%), and contrast-to-noise ratio (CNR), defined as the ratio between CRC and N%. Furthermore, image distortion is characterized by calculating the aspect ratio (AR) of ellipses fitted to the hot spheres. Additionally, the performance of these algorithms to reconstruct clinical images was investigated. Images reconstructed with 3DOSEM algorithms demonstrated superior image quality in terms of contrast and resolution recovery when compared to images reconstructed with filtered-back-projection (FBP), OSEM and 2DOSEM. However, occurrence of correlated noise patterns and image distortions significantly deteriorated the quality of 3DOSEM reconstructed images. The mean AR for the 37, 28, 22, and 17mm spheres was 1.3, 1.3, 1.6, and 1.7 respectively. The mean N% increase in high and low count Flash3D and Hybrid Recon 3DOSEM from 5.9% and 4.0% to 11.1% and 9.0%, respectively. Similarly, the mean CNR decreased in high and low count Flash3D and Hybrid Recon 3DOSEM from 8.7 and 8.8 to 3.6 and 4.2, respectively. Regularization with smoothing priors could suppress these noise patterns at the cost of reduced image contrast. The mean N% was 6.4% and 6.8% for low count QSP and MRP MAP reconstructed images. Alternatively, regularization with an anatomical Bowhser prior resulted in sharp images with high contrast, limited image distortion, and low N% of 8.3% in low count images, although some image artifacts did occur. Analysis of clinical images suggested that the same effects occur in clinical imaging. Image quality of low count SPECT acquisitions reconstructed with modern 3DOSEM algorithms is deteriorated by the occurrence of correlated noise patterns and image distortions. The artifacts observed in the phantom experiments can also occur in clinical imaging. Copyright © 2015. Published by Elsevier GmbH.
Technetium Incorporation in Glass for the Hanford Tank Waste Treatment and Immobilization Plant
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kruger, Albert A.; Kim, Dong Sang
2015-01-14
A priority of the United States Department of Energy (U.S. DOE) is to dispose of nuclear wastes accumulated in 177 underground tanks at the Hanford Nuclear Reservation in eastern Washington State. These nuclear wastes date from the Manhattan Project of World War II and from plutonium production during the Cold War. The DOE plans to separate high-level radioactive wastes from low activity wastes and to treat each of the waste streams by vitrification (immobilization of the nuclides in glass) for disposal. The immobilized low-activity waste will be disposed of here at Hanford and the immobilized high-level waste at the nationalmore » geologic repository. Included in the inventory of highly radioactive wastes is large volumes of 99Tc (~9 × 10E2 TBq or ~2.5 × 104 Ci or ~1500 kg). A problem facing safe disposal of Tc-bearing wastes is the processing of waste feed into in a chemically durable waste form. Technetium incorporates poorly into silicate glass in traditional glass melting. It readily evaporates during melting of glass feeds and out of the molten glass, leading to a spectrum of high-to-low retention (ca. 20 to 80%) in the cooled glass product. DOE-ORP currently has a program at Pacific Northwest National Laboratory (PNNL), in the Department of Materials Science and Engineering at Rutgers University and in the School of Mechanical and Materials Engineering at Washington State University that seeks to understand aspects of Tc retention by means of studying Tc partitioning, molten salt formation, volatilization pathways, and cold cap chemistry. Another problem involves the stability of Tc in glass in both the national geologic repository and on-site disposal after it has been immobilized. The major environmental concern with 99Tc is its high mobility in addition to a long half-life (2.1×105 yrs). The pertechnetate ion (TcO4-) is highly soluble in water and does not adsorb well onto the surface of minerals and so migrates nearly at the same velocity as groundwater. Long-term corrosion of glass waste forms is an area of current interest to the DOE, but attention to the release of Tc from glass has been little explored. It is expected that the release of Tc from glass should be highly dependent on the local glass structure as well as the chemistry of the surrounding environment, including groundwater pH. Though the speciation of Tc in glass has been previously studied, and the Tc species present in waste glass have been previously reported, environmental Tc release mechanisms are poorly understood. The recent advances in Tc chemistry that have given rise to an understanding of incorporation in the glass giving rise to significantly higher single-pass retention during vitrification are presented. Additionally, possible changes to the baseline flowsheet that allow for relatively minor volumes of Tc reporting to secondary waste treatment will be discussed.« less
NASA Astrophysics Data System (ADS)
Soares, Scheila F.; Brito, Lavínia C.; Souza, Deise E.; Bernardo, Luciana C.; Oliveira, Joelma F.; Bernardo-Filho, Mario
2006-12-01
Single photon emission computed tomography (SPECT) allows studies of physiological or pathological processes. Red blood cells labeled with technetium-99m ( 99mTc-RBC) are used as a radiopharmaceutical in several evaluations. The radiolabeling efficiency and bioavailability of radiopharmaceuticals can be altered by natural/synthetic drugs and may induce pitfalls in the analysis of the nuclear medicine imaging. The labeling with 99mTc requires a reducing agent and stannous chloride (SnCl 2) is widely utilized. However, SnCl 2 presents a citotoxic and/or genotoxic potential in Escherichia coli ( E. coli) strains. The aim of this work was to evaluate the influence of aqueous extracts of Baccharis genistelloides (BG), Terminalia chebula (TC), Maytenus ilicifolia (MI), Cassia angustifolia (CA) and Equisetum arvense (EA) on (i) radiolabeling of blood constituents, (ii) bioavailability of sodium pertechnetate(Na 99mTcO 4) radiopharmaceutical, (iii) survival of E. coli. In vitro labeling of RBC was performed with blood ( Wistar rats) incubated with each extract, SnCl 2 and Na 99mTcO 4. Plasma (P) and blood cells (BC) were isolated, another aliquots precipitated and soluble (SF) and insoluble (IF) fractions isolated and counted. In the bioavailability of Na 99mTcO 4, Wistar rats were treated (7 days) with aqueous extract or with 0.9%NaCl, the radiopharmaceutical was administered, the animals sacrificed, the organs isolated, weighted and radioactivity counted. To evaluate the effect on the bacterial survival, E. coli was treated with: (a) SnCl 2; (b) 0.9% NaCl; (c) vegetal extract; or (d) SnCl 2 and vegetal extract. Radiolabeling efficiency showed a significantly decrease (ANOVA/Tukey post-test, p<0.05) after treatment with BG, TC, MI and CA extracts. The bioavailability results showed that the uptake of Na 99mTcO 4 was altered significantly (unpaired t-student test, p<0.05) in blood, lungs (CA/TC extracts), bone, heart, ovary (EA /TC), spleen, kidney (TC) , pancreas, thyroid (CA) and liver (all the extracts). The alterations promoted by TC extract could be related to cardiotonic, antidiabetes and renal toxicity. The alteration in liver in EA and CA extracts could be related to its hepatoprotective activities. The extracts (EA, MI, BG) were not capable to interfere in the survival of E. coli. Moreover, these extracts have protected the E. coli against the SnCl 2 action and this fact can be related to the free radical scavenging properties of the chemical compounds of the extracts. In conclusion these findings could be worthwhile to try to understand and to avoid some pitfalls in the nuclear medicine.
SPECT Imaging for in vivo tracking of NIS containing stem cells
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lee, Zhenghong
2013-04-02
The proposed study contains two groups of imaging experiments: 1) human mesenchymal stem cells supporting in vivo survival of unrelated donor hematopoietic stem cells; 2) gene transduction and selection of mutant MGMT genes on human hematopoietic stem cells conferring resistance to BC+BCNU. There is increasing evidence that adult human tissues harbor stem and progenitor cells that can be used for therapeutic purposes. We had focused on the Mesenchymal Stem Cells (MSCs) found in human bone marrow and investigated these cells in the context of autologous and allogeneic hematopoietic stem cell transplantation to a) facilitate rapid hematopoietic engraftment in cancer patientsmore » receiving high dose chemotherapy and b) to modulate the graft-versus-host disease (GVHD). We have demonstrated that culture-expanded autologous and allogeneic MSCs can be safely infused into humans and the preliminary results showed that MSCs facilitate hematopoietic engraftment and reduce GVHD. On the other hand, studies of gene transfer with drug resistant selection suggest major perturbations to the process of hematopoietic reconstitution and the confounding issue of organ toxicity and recovery that takes place in the host. We have found that limiting numbers of hematopoietic stem cells transduced with MGMT repopulate the bone marrow of primary and secondary recipient mice. We are also particularly interested in the dynamics of engraftment and selection in regions of bones, liver, spleen and lung, where we have previously seen marked evidence of engraftment. All the measurements have required animal sacrifice and single point determinations of engraftment in individual and cohorts of mice. Heretofore it has not been possible to study the dynamics of engraftment and enrichment. In the upcoming application, we propose to develop an imaging method to track intravenously infused stem cells in vivo at preset time points to understand their homing and proliferation. Specifically, we propose to use Na+/I- symporter (NIS) gene as a reporter gene (imagene) for non-invasive imaging of infused stem cells distribution and persistence in vivo on small animal models. NIS is an intrinsic membrane glycoprotein that mediates active iodide (I-) uptake into normal thyroid follicular cells and other cells. The advantages of using NIS for non-invasive and repeated scintigraphic imaging in this application are: a) NIS is not a foreign gene and thus eliminate the immunoresponse problem; b) radiotracer or substrate for NIS is simply radioiodide (I-125, I- 123, I-124, and I-124) or [Tc-99m]-pertechnetate, no radiosynthesis is needed. It has been shown that NIS gene transfer can induce radioactive iodide uptake in a variety of cells and that xenografts expressing exogenous NIS could be imaged by non-invasive scintigraphic imaging. The specific aims are: 1.Determine the feasibility, stability and physiological effects of human NIS gene expression on human HSCs and MSCs in vitro. 2.Determine the engraftment of human HSC and MSC co-infused in NOD-SCID mice. 3.Transduce both a drug resistance gene and an imagene into bone marrow stem cells, and follow the dynamics of engraftment after selection in real time.« less
Bioreduction of Fe-bearing clay minerals and their reactivity toward pertechnetate (Tc-99)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bishop, Michael E.; Dong, Hailiang; Kukkadapu, Ravi K.
2011-07-01
99Technetium (99Tc) is a fission product of uranium-235 and plutonium-239 and poses a high environmental hazard due to its long half-life (t1/2 = 2.13 x 105 y), abundance in nuclear wastes, and environmental mobility under oxidizing conditions [i.e., Tc(VII)]. Under reducing conditions, Tc(VII) can be reduced to insoluble Tc(IV). Ferrous iron [Fe(II)], either in aqueous form or in mineral form, has been used to reduce Tc(VII) to Tc(IV). However, the reactivity of Fe(II) from clay minerals, other than nontronite, toward immobilization of Tc(VII) and its role in retention of reduced Tc(IV) have not been investigated. In this study the reactivitymore » of a suite of clay minerals toward Tc(VII) reduction and immobilization was evaluated. The clay minerals chosen for this study included five members in the smectite-illite (S-I) series, (montmorillonite, nontronite, rectorite, mixed layered I-S, and illite), chlorite, and palygorskite. Fe-oxides were removed from these minerals with a modified dithionite-citrate-bicarbonate (DCB) procedure. The total Fe content of these clay minerals, after Fe-oxide removal, ranged from 0.7 to 30.4% by weight, and the Fe(III)/Fe(total) ratio ranged from 44.9 to 98.5%. X-ray diffraction (XRD) and Mössbauer spectroscopy results showed that after Fe oxide removal the clay minerals were free of Fe-oxides. Scanning electron microscopy (SEM) revealed that little dissolution occurred during the DCB treatment. Bioreduction experiments were performed in bicarbonate buffer (pH-7) with Fe(III) in the clay minerals as the sole electron acceptor, lactate as the sole electron donor, and Shewanella Putrifaciens CN32 cells as mediators. In select tubes, anthraquinone-2,6-disulfate (AQDS) was added as electron shuttle to facilitate electron transfer. The extent of Fe(III) bioreduction was the highest for chlorite (~43 wt%) and the lowest for palygorskite (~4.17 wt%). In the S-I series, NAu-2 was the most reducible (~31 %) and illite the least (~0.4 %). The extent and initial rate of bioreduction were positively correlated with the percent smectite in the S-I series (i.e., layer expandability). Fe(II) in the bioreduced clay minerals subsequently was used to reduce Tc(VII) to Tc(IV) in PIPES buffer. Similar to the trend of bioreduction, in the S-I series, reduced smectite showed the highest reactivity toward Tc(VII), and reduced illite exhibited the least. The initial rate of Tc(VII) reduction, after normalization to clay and Fe(II) concentrations, was positively correlated with the percent smectite in the S-I series. Fe(II) in chlorite and palygorskite was also reactive toward Tc(VII) reduction. These data demonstrate that crystal chemical parameters (layer expandability, Fe and Fe(II) contents, and surface area etc.) play important roles in controlling the extent and rate of bioreduction and the reactivity toward Tc(VII) reduction. Reduced Tc(IV) resides within clay mineral matrix, and this association could minimize any potential of reoxidation over long term.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Taylor-Pashow, K.; Nash, C.; McCabe, D.
2014-09-29
The Hanford Waste Treatment and Immobilization Plant (WTP) Low Activity Waste (LAW) vitrification facility will generate an aqueous condensate recycle stream (LAW Off-Gas Condensate) from the off-gas system. The baseline plan for disposition of this stream is to send it to the WTP Pretreatment Facility, where it will be blended with LAW, concentrated by evaporation and recycled to the LAW vitrification facility again. Alternate disposition of this stream would eliminate recycling of problematic components, and would enable de-coupled operation of the LAW melter and the Pretreatment Facilities. Eliminating this stream from recycling within WTP would also decrease the LAW vitrificationmore » mission duration and quantity of glass waste. This LAW Off-Gas Condensate stream contains components that are volatile at melter temperatures and are problematic for the glass waste form. Because this stream recycles within WTP, these components accumulate in the Condensate stream, exacerbating their impact on the number of LAW glass containers that must be produced. Approximately 32% of the sodium in Supplemental LAW comes from glass formers used to make the extra glass to dilute the halides to acceptable concentrations in the LAW glass, and diverting the stream reduces the halides in the recycled Condensate and is a key outcome of this work. Additionally, under possible scenarios where the LAW vitrification facility commences operation prior to the WTP Pretreatment facility, identifying a disposition path becomes vitally important. This task examines the potential treatment of this stream to remove radionuclides and subsequently disposition the decontaminated stream elsewhere, such as the Effluent Treatment Facility (ETF), for example. The treatment process envisioned is very similar to that used for the Actinide Removal Process (ARP) that has been operating for years at the Savannah River Site (SRS), and focuses on using mature radionuclide removal technologies that are also compatible with longterm tank storage and immobilization methods. For this new application, testing is needed to demonstrate acceptable treatment sorbents and precipitating agents and measure decontamination factors for additional radionuclides in this unique waste stream. The origin of this LAW Off-Gas Condensate stream will be the liquids from the Submerged Bed Scrubber (SBS) and the Wet Electrostatic Precipitator (WESP) from the LAW melter off-gas system. The stream is expected to be a dilute salt solution with near neutral pH, and will likely contain some insoluble solids from melter carryover. The soluble components are expected to be mostly sodium and ammonium salts of nitrate, chloride, and fluoride. This stream has not been generated yet and will not be available until the WTP begins operation, but a simulant has been produced based on models, calculations, and comparison with pilot-scale tests. One of the radionuclides that is volatile and expected to be in greatest abundance in this LAW Off-Gas Condensate stream is Technetium-99 ({sup 99}Tc). Technetium will not be removed from the aqueous waste in the Hanford WTP, and will primarily end up immobilized in the LAW glass by repeated recycle of the off-gas condensate into the LAW melter. Other radionuclides that are low but are also expected to be in measurable concentration in the LAW Off-Gas Condensate are {sup 129}I, {sup 90}Sr, {sup 137}Cs, {sup 241}Pu, and {sup 241}Am. These are present due to their partial volatility and some entrainment in the off-gas system. This report discusses results of optimized {sup 99}Tc decontamination testing of the simulant. Testing examined use of inorganic reducing agents for {sup 99}Tc. Testing focused on minimizing the quantity of sorbents/reactants added, and minimizing mixing time to reach the decontamination targets in this simulant formulation. Stannous chloride and ferrous sulfate were tested as reducing agents to determine the minimum needed to convert soluble pertechnetate to the insoluble technetium dioxide. The reducing agents were tried with and without sorbents. The sorbents, hydroxyapatite and sodium oxalate, were expected to sorb the precipitated technetium dioxide and facilitate removal. The Phase 1 tests examined a broad range of conditions and used the initial baseline simulant. The Phase 2 tests narrowed the conditions based on Phase 1 results, and used a slightly modified simulant. Test results indicate that excellent removal of {sup 99}Tc was achieved using SnCl{sub 2} as a reductant, and was effective with or without sorption onto hydroxyapatite. This reaction worked even in the presence of air (which could oxidize the stannous ion) and at room temperature. This process was very effective at neutral pH, with a Decontamination Factor (DF) >199 in one hour with only 1 g/L of SnCl{sub 2}. Prior work had shown that it was much less effective at alkaline pH. The only deleterious effect observed was that the chromium co-precipitates with the {sup 99}c during the SnCl{sub 2} reduction. This effect was anticipated, and would have to be considered when managing disposition paths of this stream. Reduction using FeSO{sub 4} was not effective at removing {sup 99}Tc, but did remove the Cr. Chromium is present due to partial volatility and entrainment in the off-gas, and is highly oxidizing, so would be expected to react with reducing agents more quickly than pertechnetate. Testing showed that sufficient reducing agent must be added to completely reduce the chromium before the technetium is reduced and removed. Other radionuclides are also present in this off-gas condensate stream. To enable sending this stream to the Hanford ETF, and thereby divert it from the recycle where it impacts the LAW glass volume, several of these also need to be removed. Samples from optimized conditions were also measured for actinide removal in order to examine the effect of the Tc-removal process on the actinides. Plutonium was also removed by the SnCl{sub 2} precipitation process. Results of this separation testing indicate that sorption/precipitation is a viable concept and has the potential to decontaminate the {sup 99}Tc from the stream, allowing it to be diverted away from WTP and thus eliminating the impact of the recycled halides and sulfate on the LAW glass volume. Based on the results, a possible treatment scenario could involve the use of a reductive precipitation agent (SnCl{sub 2}) with or without sorbent at neutral pH to remove the Tc. Although hydroxyapatite was not necessary to effect the {sup 99}Tc removal, it may be beneficial in solid-liquid separations. Other testing will examine removal of the other radionuclides. This testing was the second phase of testing, which aimed at optimizing the process by examining the minimum amount of reductant needed and the minimum reaction time. Although results indicated that SnCl{sub 2} was effective, further work on a pH-adjusted Fe(SO{sub 4}) mixture are needed. Additional tasks are needed to examine removal of the other radionuclides, solid-liquid separation technologies, slurry rheology measurements, composition variability impacts, corrosion and erosion, and slurry storage and immobilization.« less
NASA Astrophysics Data System (ADS)
Albrecht, A.; Leone, L.; Charlet, L.
2009-04-01
Micro-organisms are ubiquitous and display remarkable capabilities to adapt and survive in the most extreme environmental conditions. It has been recognized that microorganisms can survive in nuclear waste disposal facilities if the required major (P, N, K) and trace elements, a carbon and energy source as well as water are present. The space constraint is of particular interest as it has been shown that bacteria do not prosper in compacted clay. An evaluation of the different types of French medium and high level waste, in a clay-rich host rock storage environment at a depth between 500 and 600 m, has shown that the bituminous waste is the most likely candidate to accommodate significant microbial activity. The waste consists of a mixture of bitumen (source of bio-available organic matter and H2 as a consequence of its degradation and radiolysis) and nitrates and sulphates kept in a stainless steel container. The assumption, that microbes only have an impact on reaction kinetics needs to be reassessed in the case where nitrates and sulphates are present since both are known not to react at low temperatures without bacterial catalysis. The additional impact of both oxy-anions and their reduced species on redox conditions, radionuclide speciation and mobility gives this evaluation their particular relevance. Storage architecture proposes four primary waste containers positioned into armoured cement over packs and placed with others into the waste storage cell itself composed of a cement mantle enforcing the argillite host rock, the latter being characterized by an excavation damaged zone constricted both in space and in time and a pristine part of 60 m thickness. Bacterial activity within the waste and within the pristine argillite is disregarded because of the low water activity (< 0.7) and the lack of space, respectively. The most probable zones of microbial activity, those likely to develop sustainable biofilms are within the interface zones. A major restriction for the initial development of microbial colonies is the high pH controlled by the cement solution. Archea are able to survive at high pH, when hydrogen gas is available as an energy sources; they are therefore likely candidates for an initial biofilm formation. It can not be excluded that other micro-organisms such as fungi may develop as well in such conditions. It also needs to be evaluated how conditions change with time and how this affects microbial ecology. The following is known about the impact of microbes on the waste cell biogeochemistry: • enhancement of redox reaction kinetics (particularly involving nitrates, sulphate, selenate, pertechnetate, organic matter and H2), thus a faster move towards reducing conditions, important to guarantee the low mobility of critical RN, • increased retardation of mobile RN in biofilms (i.e. adsorption on microbial cell surfaces and products of possible biomineralization); complexation by embedded extracellular polymeric substances, • secretion of organic substances (i.e siderophores) known to complex RN and to enhance their mobility, • biodegradation of dissolved organic substances, such as those released form the waste (organic acids) or generated by microbes, • production of CO2 or other gases that may affect cement integrity. Quantification of microbial activity has been implemented into biogeochemical models but the important parameters describing their evolution and metabolism in the real system (ecology, mass, energy sources, metabolites) need to be obtained via specific empirical studies. Such studies require a particular trans-disciplinary approach that brings together the competence of chemical and environmental engineers, microbiologists and system modellers.
CHEMICAL DIFFERENCES BETWEEN SLUDGE SOLIDS AT THE F AND H AREA TANK FARMS
DOE Office of Scientific and Technical Information (OSTI.GOV)
Reboul, S.
2012-08-29
The primary source of waste solids received into the F Area Tank Farm (FTF) was from PUREX processing performed to recover uranium and plutonium from irradiated depleted uranium targets. In contrast, two primary sources of waste solids were received into the H Area Tank Farm (HTF): a) waste from PUREX processing; and b) waste from H-modified (HM) processing performed to recover uranium and neptunium from burned enriched uranium fuel. Due to the differences between the irradiated depleted uranium targets and the burned enriched uranium fuel, the average compositions of the F and H Area wastes are markedly different from onemore » another. Both F and H Area wastes contain significant amounts of iron and aluminum compounds. However, because the iron content of PUREX waste is higher than that of HM waste, and the aluminum content of PUREX waste is lower than that of HM waste, the iron to aluminum ratios of typical FTF waste solids are appreciably higher than those of typical HTF waste solids. Other constituents present at significantly higher concentrations in the typical FTF waste solids include uranium, nickel, ruthenium, zinc, silver, cobalt and copper. In contrast, constituents present at significantly higher concentrations in the typical HTF waste solids include mercury, thorium, oxalate, and radionuclides U-233, U-234, U-235, U-236, Pu-238, Pu-242, Cm-244, and Cm-245. Because of the higher concentrations of Pu-238 in HTF, the long-term concentrations of Th-230 and Ra-226 (from Pu-238 decay) will also be higher in HTF. The uranium and plutonium distributions of the average FTF waste were found to be consistent with depleted uranium and weapons grade plutonium, respectively (U-235 comprised 0.3 wt% of the FTF uranium, and Pu-240 comprised 6 wt% of the FTF plutonium). In contrast, at HTF, U-235 comprised 5 wt% of the uranium, and Pu-240 comprised 17 wt% of the plutonium, consistent with enriched uranium and high burn-up plutonium. X-ray diffraction analyses of various FTF and HTF samples indicated that the primary crystalline compounds of iron in sludge solids are Fe{sub 2}O{sub 3}, Fe{sub 3}O{sub 4}, and FeO(OH), and the primary crystalline compounds of aluminum are Al(OH){sub 3} and AlO(OH). Also identified were carbonate compounds of calcium, magnesium, and sodium; a nitrated sodium aluminosilicate; and various uranium compounds. Consistent with expectations, oxalate compounds were identified in solids associated with oxalic acid cleaning operations. The most likely oxidation states and chemical forms of technetium are assessed in the context of solubility, since technetium-99 is a key risk driver from an environmental fate and transport perspective. The primary oxidation state of technetium in SRS sludge solids is expected to be Tc(IV). In salt waste, the primary oxidation state is expected to be Tc(VII). The primary form of technetium in sludge is expected to be a hydrated technetium dioxide, TcO{sub 2} {center_dot} xH{sub 2}O, which is relatively insoluble and likely co-precipitated with iron. In salt waste solutions, the primary form of technetium is expected to be the very soluble pertechnetate anion, TcO{sub 4}{sup -}. The relative differences between the F and H Tank Farm waste provide a basis for anticipating differences that will occur as constituents of FTF and HTF waste residue enter the environment over the long-term future. If a constituent is significantly more dominant in one of the Tank Farms, its long-term environmental contribution will likely be commensurately higher, assuming the environmental transport conditions of the two Tank Farms share some commonality. It is in this vein that the information cited in this document is provided - for use during the generation, assessment, and validation of Performance Assessment modeling results.« less
Matovic, Milovan; Jankovic, Milica; Barjaktarovic, Marko; Jeremic, Marija
2017-01-01
After radioiodine therapy of differentiated thyroid cancer (DTC) patients, whole body scintigraphy (WBS) is standard procedure before releasing the patient from the hospital. A common problem is the precise localization of regions where the iod-avide tissue is located. Sometimes is practically impossible to perform precise topographic localization of such regions. In order to face this problem, we have developed a low-cost Vision-Fusion system for web-camera image acquisition simultaneously with routine scintigraphic whole body acquisition including the algorithm for fusion of images given from both cameras. For image acquisition in the gamma part of the spectra we used e.cam dual head gamma camera (Siemens, Erlangen, Germany) in WBS modality, with matrix size of 256×1024 pixels and bed speed of 6cm/min, equipped with high energy collimator. For optical image acquisition in visible part of spectra we have used web-camera model C905 (Logitech, USA) with Carl Zeiss® optics, native resolution 1600×1200 pixels, 34 o field of view, 30g weight, with autofocus option turned "off" and auto white balance turned "on". Web camera is connected to upper head of gamma camera (GC) by a holder of lightweight aluminum rod and a plexiglas adapter. Our own Vision-Fusion software for image acquisition and coregistration was developed using NI LabVIEW programming environment 2015 (National Instruments, Texas, USA) and two additional LabVIEW modules: NI Vision Acquisition Software (VAS) and NI Vision Development Module (VDM). Vision acquisition software enables communication and control between laptop computer and web-camera. Vision development module is image processing library used for image preprocessing and fusion. Software starts the web-camera image acquisition before starting image acquisition on GC and stops it when GC completes the acquisition. Web-camera is in continuous acquisition mode with frame rate f depending on speed of patient bed movement v (f=v/∆ cm , where ∆ cm is a displacement step that can be changed in Settings option of Vision-Fusion software; by default, ∆ cm is set to 1cm corresponding to ∆ p =15 pixels). All images captured while patient's bed is moving are processed. Movement of patient's bed is checked using cross-correlation of two successive images. After each image capturing, algorithm extracts the central region of interest (ROI) of the image, with the same width as captured image (1600 pixels) and the height that is equal to the ∆ p displacement in pixels. All extracted central ROI are placed next to each other in the overall whole-body image. Stacking of narrow central ROI introduces negligible distortion in the overall whole-body image. The first step for fusion of the scintigram and the optical image was determination of spatial transformation between them. We have made an experiment with two markers (point radioactivity sources of 99m Tc pertechnetate 1MBq) visible in both images (WBS and optical) to find transformation of coordinates between images. The distance between point markers is used for spatial coregistration of the gamma and optical images. At the end of coregistration process, gamma image is rescaled in spatial domain and added to the optical image (green or red channel, amplification changeable from user interface). We tested our system for 10 patients with DTC who received radioiodine therapy (8 women and two men, with average age of 50.10±12.26 years). Five patients received 5.55Gbq, three 3.70GBq and two 1.85GBq. Whole-body scintigraphy and optical image acquisition were performed 72 hours after application of radioiodine therapy. Based on our first results during clinical testing of our system, we can conclude that our system can improve diagnostic possibility of whole body scintigraphy to detect thyroid remnant tissue in patients with DTC after radioiodine therapy.
Ortiz-Arzate, Zareth; Santos-Cuevas, Clara L; Ocampo-García, Blanca E; Ferro-Flores, Guillermina; García-Becerra, Rocío; Estrada, Gisela; Gómez-Argumosa, Edgar; Izquierdo-Sánchez, Vanessa
2014-04-01
In breast cancer, α(ν)β(3) and/or α(ν)β(5) integrins are overexpressed in both endothelial and tumour cells. Radiolabelled peptides based on the Arg-Gly-Asp (RGD) sequence are radiopharmaceuticals with high affinity and selectivity for these integrins. The RGD-dimer peptide (E-[c(RGDfK)]2) radiolabelled with (99m)Tc has been reported as a radiopharmaceutical with a 10-fold higher affinity for the α(ν)β(3) integrin compared with the RGD-monomer. Ethylenediamine-N,N'-diacetic acid (EDDA) is a hydrophilic molecule that may favour renal excretion when used as coligand in the (99m)Tc labelling of hydrazinonicotinamide (HYNIC) peptides and can easily be formulated in a lyophilized kit. The aim of this study was to establish a biokinetic model for (99m)Tc-EDDA/HYNIC-E-[c(RGDfK)]2 prepared from lyophilized kits and evaluate its dosimetry as a tumour-imaging agent in seven healthy women and three breast cancer patients. (99m)Tc labelling was performed by adding sodium pertechnetate solution and 0.2 mol/l phosphate buffer (pH 7.0) to a lyophilized formulation containing E-[c(RGDfK)]2, EDDA, tricine, mannitol and stannous chloride. The radiochemical purity was evaluated using reverse-phase high-performance liquid chromatography and instant thin-layer chromatography on silica gel analyses. Stability studies in human serum were carried out using size-exclusion high-performance liquid chromatography. In-vitro cell uptake was tested using breast cancer cells (MCF7, T47D and MDA-MB-231) with blocked and nonblocked receptors. Biodistribution and tumour uptake were determined in MCF7 tumour-bearing nude mice with blocked and nonblocked receptors, and images were obtained using a micro-SPECT/PET/CT. Whole-body images from seven healthy women were acquired at 0.5, 1, 3, 6 and 24 h after (99m)Tc-EDDA/HYNIC-E-[c(RGDfK)]2 administration with radiochemical purities greater than 94%. Regions of interest were drawn around the source organs at each time frame. Each region of interest was converted to activity using the conjugate view counting method. The image sequence was used to extrapolate the (99m)Tc-EDDA/HYNIC-E-[c(RGDfK)]2 time-activity curves of each organ to adjust the biokinetic model and calculate the total number of disintegrations (N) that occurred in the source regions. N data were the input for the OLINDA/EXM code to calculate internal radiation dose estimates. In three breast cancer patients with histologically confirmed cancer, static images were obtained at 1 h in the supine position with hands placed behind the head. (99m)Tc-EDDA/HYNIC-E-[c(RGDfK)]2 obtained from lyophilized kits demonstrated high stability in human serum and specific cell receptor binding. The biodistribution data from mice showed rapid blood clearance, with both renal and hepatobiliary excretion, and specific binding towards α(ν)β(3) integrins in the MCF7 tumours. In women, the blood activity showed a half-life value of 1.60 min for the fast component (T1/2α = ln2/26.01) and half-life values of 1.0 h for the first slow component (T1/2β = ln2/0.69) and 4.03 h for the second slow component (T1/2γ = ln2/0.16). Images from patients showed an average tumour/heart (blood) ratio of 3.61 ± 0.62 at 1 h. The average equivalent doses calculated for a study using 740 MBq were 4.9, 6.2, 20.7, 34.5 and 57.0 mSv for the liver, intestines, spleen, kidneys and thyroid, respectively, and the effective dose was 6.1 mSv. All absorbed doses were comparable to those known from most of the (99m)Tc studies. (99m)Tc-EDDA/HYNIC-E-[c(RGDfK)]2 obtained from kit formulations showed high tumour uptake in patients with malignant lesions, making it a promising imaging radiopharmaceutical for targeting site-specific breast cancer. The results obtained in this study warrant further clinical studies to determine the specificity and sensitivity of (99m)Tc-EDDA/HYNIC-E-[c(RGDfK)]2.