  1. Dual-Modality PET/Ultrasound imaging of the Prostate

    SciTech Connect

    Huber, Jennifer S.; Moses, William W.; Pouliot, Jean; Hsu, I.C.

    2005-11-11

    Functional imaging with positron emission tomography (PET)will detect malignant tumors in the prostate and/or prostate bed, as well as possibly help determine tumor ''aggressiveness''. However, the relative uptake in a prostate tumor can be so great that few other anatomical landmarks are visible in a PET image. Ultrasound imaging with a transrectal probe provides anatomical detail in the prostate region that can be co-registered with the sensitive functional information from the PET imaging. Imaging the prostate with both PET and transrectal ultrasound (TRUS) will help determine the location of any cancer within the prostate region. This dual-modality imaging should help provide better detection and treatment of prostate cancer. LBNL has built a high performance positron emission tomograph optimized to image the prostate.Compared to a standard whole-body PET camera, our prostate-optimized PET camera has the same sensitivity and resolution, less backgrounds and lower cost. We plan to develop the hardware and software tools needed for a validated dual PET/TRUS prostate imaging system. We also plan to develop dual prostate imaging with PET and external transabdominal ultrasound, in case the TRUS system is too uncomfortable for some patients. We present the design and intended clinical uses for these dual imaging systems.

  2. Dual-Modality Prostate Imaging with PET and Transrectal Ultrasound

    DTIC Science & Technology

    2011-09-01

    Emission Tomography–Transrectal Ultrasound (PET-TRUS) imaging of the prostate and validate the technology with phantom and “proof of principle” human...position a prostate near the PET-center, and this method was also used for phantom imaging in Years 2-5. The TRUS probe is rigidly attached to the TRUS...scanner table. This stabilizer arm moves to allow correct positioning of the TRUS probe in a human subject (or phantom ), then its position is fixed by

  3. Carbon-11 radiolabeling of iron-oxide nanoparticles for dual-modality PET/MR imaging

    NASA Astrophysics Data System (ADS)

    Sharma, Ramesh; Xu, Youwen; Kim, Sung Won; Schueller, Michael J.; Alexoff, David; Smith, S. David; Wang, Wei; Schlyer, David

    2013-07-01

    Dual-modality imaging, using Magnetic Resonance Imaging (MRI) and Positron Emission Tomography (PET) simultaneously, is a powerful tool to gain valuable information correlating structure with function in biomedicine. The advantage of this dual approach is that the strengths of one modality can balance the weaknesses of the other. However, success of this technique requires developing imaging probes suitable for both. Here, we report on the development of a nanoparticle labeling procedure via covalent bonding with carbon-11 PET isotope. Carbon-11 in the form of [11C]methyl iodide was used as a methylation agent to react with carboxylic acid (-COOH) and amine (-NH2) functional groups of ligands bound to the nanoparticles (NPs). The surface coating ligands present on superparamagnetic iron-oxide nanoparticles (SPIO NPs) were radiolabeled to achieve dual-modality PET/MR imaging capabilities. The proof-of-concept dual-modality PET/MR imaging using the radiolabeled SPIO NPs was demonstrated in an in vivo experiment.Dual-modality imaging, using Magnetic Resonance Imaging (MRI) and Positron Emission Tomography (PET) simultaneously, is a powerful tool to gain valuable information correlating structure with function in biomedicine. The advantage of this dual approach is that the strengths of one modality can balance the weaknesses of the other. However, success of this technique requires developing imaging probes suitable for both. Here, we report on the development of a nanoparticle labeling procedure via covalent bonding with carbon-11 PET isotope. Carbon-11 in the form of [11C]methyl iodide was used as a methylation agent to react with carboxylic acid (-COOH) and amine (-NH2) functional groups of ligands bound to the nanoparticles (NPs). The surface coating ligands present on superparamagnetic iron-oxide nanoparticles (SPIO NPs) were radiolabeled to achieve dual-modality PET/MR imaging capabilities. The proof-of-concept dual-modality PET/MR imaging using the radiolabeled

  4. Dual-modality brain PET-CT image segmentation based on adaptive use of functional and anatomical information.

    PubMed

    Xia, Yong; Eberl, Stefan; Wen, Lingfeng; Fulham, Michael; Feng, David Dagan

    2012-01-01

    Dual medical imaging modalities, such as PET-CT, are now a routine component of clinical practice. Medical image segmentation methods, however, have generally only been applied to single modality images. In this paper, we propose the dual-modality image segmentation model to segment brain PET-CT images into gray matter, white matter and cerebrospinal fluid. This model converts PET-CT image segmentation into an optimization process controlled simultaneously by PET and CT voxel values and spatial constraints. It is innovative in the creation and application of the modality discriminatory power (MDP) coefficient as a weighting scheme to adaptively combine the functional (PET) and anatomical (CT) information on a voxel-by-voxel basis. Our approach relies upon allowing the modality with higher discriminatory power to play a more important role in the segmentation process. We compared the proposed approach to three other image segmentation strategies, including PET-only based segmentation, combination of the results of independent PET image segmentation and CT image segmentation, and simultaneous segmentation of joint PET and CT images without an adaptive weighting scheme. Our results in 21 clinical studies showed that our approach provides the most accurate and reliable segmentation for brain PET-CT images.

  5. TU-AB-BRA-06: Texture Feature Reproducibility Between PET/CT and PET/MR Imaging Modalities

    SciTech Connect

    Galavis, P; Friedman, K; Chandarana, H; Jackson, K

    2015-06-15

    Purpose: Radiomics involves the extraction of texture features from different imaging modalities with the purpose of developing models to predict patient treatment outcomes. The purpose of this study is to investigate texture feature reproducibility across [18F]FDG PET/CT and [18F]FDG PET/MR imaging in patients with primary malignancies. Methods: Twenty five prospective patients with solid tumors underwent clinical [18F]FDG PET/CT scan followed by [18F]FDG PET/MR scans. In all patients the lesions were identified using nuclear medicine reports. The images were co-registered and segmented using an in-house auto-segmentation method. Fifty features, based on the intensity histogram, second and high order matrices, were extracted from the segmented regions from both image data sets. One-way random-effects ANOVA model of the intra-class correlation coefficient (ICC) was used to establish texture feature correlations between both data sets. Results: Fifty features were classified based on their ICC values, which were found in the range from 0.1 to 0.86, in three categories: high, intermediate, and low. Ten features extracted from second and high-order matrices showed large ICC ≥ 0.70. Seventeen features presented intermediate 0.5 ≤ ICC ≤ 0.65 and the remaining twenty three presented low ICC ≤ 0.45. Conclusion: Features with large ICC values could be reliable candidates for quantification as they lead to similar results from both imaging modalities. Features with small ICC indicates a lack of correlation. Therefore, the use of these features as a quantitative measure will lead to different assessments of the same lesion depending on the imaging modality from where they are extracted. This study shows the importance of the need for further investigation and standardization of features across multiple imaging modalities.

  6. Dual-Modality Prostate Imaging with PET and Transrectal Ultrasound

    DTIC Science & Technology

    2009-04-01

    concentrations than the “pelvis.” Both TMMs were hardened at room temperature. These PET- TRUS-CT-MRI phantoms are stored with a thin layer of safflower ...hardened at room temperature. Theses phantoms are stored with a thin layer of safflower oil on top to minimize dehydration and shrinkage. Fig. 2

  7. Novel Strategy for Preparing Dual-Modality Optical/PET Imaging Probes via Photo-Click Chemistry.

    PubMed

    Sun, Lingyi; Ding, Jiule; Xing, Wei; Gai, Yongkang; Sheng, Jing; Zeng, Dexing

    2016-05-18

    Preparation of small molecule based dual-modality probes remains a challenging task due to the complicated synthetic procedure. In this study, a novel concise and generic strategy for preparing dual-modality optical/PET imaging probes via photo-click chemistry was developed, in which the diazole photo-click linker functioned not only as a bridge between the targeting-ligand and the PET imaging moiety, but also as the fluorophore for optical imaging. A dual-modality AE105 peptidic probe was successfully generated via this strategy and subsequently applied in the fluorescent staining of U87MG cells and the (68)Ga based PET imaging of mice bearing U87MG xenograft. In addition, dual-modality monoclonal antibody cetuximab has also been generated via this strategy and labeled with (64)Cu for PET imaging studies, broadening the application of this strategy to include the preparation of macromolecule based imaging probes.

  8. Cerenkov Luminescence Imaging as a Modality to Evaluate Antibody-Based PET Radiotracers.

    PubMed

    D'Souza, Jimson W; Hensley, Harvey; Doss, Mohan; Beigarten, Charles; Torgov, Michael; Olafsen, Tove; Yu, Jian Q; Robinson, Matthew K

    2017-01-01

    Antibodies, and engineered antibody fragments, labeled with radioisotopes are being developed as radiotracers for the detection and phenotyping of diseases such as cancer. The development of antibody-based radiotracers requires extensive characterization of their in vitro and in vivo properties, including their ability to target tumors in an antigen-selective manner. In this study, we investigated the use of Cerenkov luminescence imaging (CLI) as compared with PET as a modality for evaluating the in vivo behavior of antibody-based radiotracers.

  9. Application of 18F-FDG PET and diffusion weighted imaging (DWI) in multiple myeloma: comparison of functional imaging modalities

    PubMed Central

    Sachpekidis, Christos; Mosebach, Jennifer; Freitag, Martin T; Wilhelm, Thomas; Mai, Elias K; Goldschmidt, Hartmut; Haberkorn, Uwe; Schlemmer, Heinz-Peter; Delorme, Stefan; Dimitrakopoulou-Strauss, Antonia

    2015-01-01

    Aim of this prospective study was to assess the sensitivity of positron emission tomography (PET) and diffusion-weighted imaging (DWI) in detecting multiple myeloma (MM) lesions, using the well-established morphologic modalities magnetic resonance imaging (MRI) and computed tomography (CT) as the standard of reference (RS). The study included 24 MM patients (15 newly diagnosed, 9 pre-treated). All underwent 18F-FDG PET/CT and wholebody DWI. The findings in PET and DWI were compared to matching imaging findings in combined non-enhanced T1w, fat-saturated T2w (TIRM)- MRI, and low-dose CT. Patient-based analysis revealed that 15/24 patients (10 primary MM, 5 pre-treated) had myeloma lesions according to our RS. PET was positive in 13/24 patients (11 primary MM, 2 pre-treated) and DWI in 18/24 patients (12 primary MM, 6 pre-treated). Lesion-based analysis demonstrated 128 MM lesions, of which PET depicted 60/128 lesions (sensitivity 47%), while DWI depicted 99/128 lesions (sensitivity 77%). Further analysis including only the 15 untreated MM patients revealed a sensitivity of 90% for both PET and DWI and an overall concordance of PET and DWI of 72%. In conclusion, DWI was more sensitive than 18F-FDG PET in detecting myeloma lesions in a mixed population of primary and pre-treated MM patients. However, 18F-FDG PET and DWI demonstrated equivalent sensitivities in the sub-population of primary, untreated MM patients. This higher sensitivity of DWI in pre-treated patients may be due to the fact that 18F-FDG PET becomes negative earlier in the course of treatment in contrary to MRI, in which already treated lesions can remain visible. PMID:26550539

  10. Intrinsically germanium-69-labeled iron oxide nanoparticles: synthesis and in-vivo dual-modality PET/MR imaging.

    PubMed

    Chakravarty, Rubel; Valdovinos, Hector F; Chen, Feng; Lewis, Christina M; Ellison, Paul A; Luo, Haiming; Meyerand, M Elizabeth; Nickles, Robert J; Cai, Weibo

    2014-08-13

    Intrinsically germanium-69-labeled super-paramagnetic iron oxide nanoparticles are synthesized via a newly developed, fast and highly specific chelator-free approach. The biodistribution pattern and the feasibility of (69) Ge-SPION@PEG for in vivo dual-modality positron emission tomography/magnetic resonance (PET/MR) imaging and lymph-node mapping are investigated, which represents the first example of the successful utilization of a (69) Ge-based agent for PET/MR imaging.

  11. Crossed Cerebellar Diaschisis: Three Case Reports Imaging Using a Tri-Modality PET/CT-MR System.

    PubMed

    Han, Shuguang; Wang, Xiaopeng; Xu, Kai; Hu, Chunfeng

    2016-01-01

    Crossed cerebellar diaschisis (CCD) describes a depression of oxidative metabolism glucose and blood flow in the cerebellum secondary to a supratentorial lesion in the contralateral cerebral hemisphere. PET/MR has the potential to become a powerful tool for demonstrating and imaging intracranial lesions .We herein report 3 cases of CCD imaging using a tri-modality PET/CT-MR set-up for investigating the value of adding MRI rather than CT to PET in clinical routine.We describe 3 patients with CCD and neurological symptoms in conjunction with abnormal cerebral fluorodeoxyglucose (FDG) positron emission tomography/computed tomography-magnetic resonance imaging (PET/CT-MR) manifestations including arterial spin-labeling (ASL) and T2-weighted images. In all, 18FDG-PET/CT detected positive FDG uptake in supratentorial lesions, and hypometabolism with atrophy in the contralateral cerebellum. More than that, hybrid PET/MRI provided a more accurate anatomic localization and ASL indicated disruption of the cortico-ponto-cerebellar pathway.Using pathology or long-term clinical follow-up to confirm the PET and ASL findings, the supratentorial lesions of the 3 patients were respectively diagnosed with cerebral infarction, recurrent glioma, and metastasis.The reports emphasize the significance of multimodality radiological examinations. Multimodality imaging contributes to proper diagnosis, management, and follow-up of supratentorial lesions with CCD.

  12. Performance evaluation of a compact PET/SPECT/CT tri-modality system for small animal imaging applications

    NASA Astrophysics Data System (ADS)

    Wei, Qingyang; Wang, Shi; Ma, Tianyu; Wu, Jing; Liu, Hui; Xu, Tianpeng; Xia, Yan; Fan, Peng; Lyu, Zhenlei; Liu, Yaqiang

    2015-06-01

    PET, SPECT and CT imaging techniques are widely used in preclinical small animal imaging applications. In this paper, we present a compact small animal PET/SPECT/CT tri-modality system. A dual-functional, shared detector design is implemented which enables PET and SPECT imaging with a same LYSO ring detector. A multi-pinhole collimator is mounted on the system and inserted into the detector ring in SPECT imaging mode. A cone-beam CT consisting of a micro focus X-ray tube and a CMOS detector is implemented. The detailed design and the performance evaluations are reported in this paper. In PET imaging mode, the measured NEMA based spatial resolution is 2.12 mm (FWHM), and the sensitivity at the central field of view (CFOV) is 3.2%. The FOV size is 50 mm (∅)×100 mm (L). The SPECT has a spatial resolution of 1.32 mm (FWHM) and an average sensitivity of 0.031% at the center axial, and a 30 mm (∅)×90 mm (L) FOV. The CT spatial resolution is 8.32 lp/mm @10%MTF, and the contrast discrimination function value is 2.06% with 1.5 mm size cubic box object. In conclusion, a compact, tri-modality PET/SPECT/CT system was successfully built with low cost and high performance.

  13. Real-time volume rendering visualization of dual-modality PET/CT images with interactive fuzzy thresholding segmentation.

    PubMed

    Kim, Jinman; Cai, Weidong; Eberl, Stefan; Feng, Dagan

    2007-03-01

    Three-dimensional (3-D) visualization has become an essential part for imaging applications, including image-guided surgery, radiotherapy planning, and computer-aided diagnosis. In the visualization of dual-modality positron emission tomography and computed tomography (PET/CT), 3-D volume rendering is often limited to rendering of a single image volume and by high computational demand. Furthermore, incorporation of segmentation in volume rendering is usually restricted to visualizing the presegmented volumes of interest. In this paper, we investigated the integration of interactive segmentation into real-time volume rendering of dual-modality PET/CT images. We present and validate a fuzzy thresholding segmentation technique based on fuzzy cluster analysis, which allows interactive and real-time optimization of the segmentation results. This technique is then incorporated into a real-time multi-volume rendering of PET/CT images. Our method allows a real-time fusion and interchangeability of segmentation volume with PET or CT volumes, as well as the usual fusion of PET/CT volumes. Volume manipulations such as window level adjustments and lookup table can be applied to individual volumes, which are then fused together in real time as adjustments are made. We demonstrate the benefit of our method in integrating segmentation with volume rendering in its application to PET/CT images. Responsive frame rates are achieved by utilizing a texture-based volume rendering algorithm and the rapid transfer capability of the high-memory bandwidth available in low-cost graphic hardware.

  14. Principles of nuclear medicine imaging: planar, SPECT, PET, multi-modality, and autoradiography systems.

    PubMed

    Zanzonico, Pat

    2012-04-01

    The underlying principles of nuclear medicine imaging involve the use of unsealed sources of radioactivity in the form of radiopharmaceuticals. The ionizing radiations that accompany the decay of the administered radioactivity can be quantitatively detected, measured, and imaged in vivo with instruments such as gamma cameras. This paper reviews the design and operating principles, as well as the capabilities and limitations, of instruments used clinically and preclinically for in vivo radionuclide imaging. These include gamma cameras, single-photon emission computed tomography (SPECT) scanners, and positron emission tomography (PET) scanners. The technical basis of autoradiography is reviewed as well.

  15. DEVELOPMENT OF A DUAL MODALITY TOMOGRAPHIC IMAGING SYSTEM FOR BIOLUMINESCENCE AND PET

    SciTech Connect

    CHATZIIOANNOU, ARION

    2011-12-21

    The goal of this proposal was to develop a new hybrid imaging modality capable to simultaneously image optical bioluminescence signals, as well as radionuclide emissions from the annihilation of positrons originating from molecular imaging probes in preclinical mouse models. This new technology enables the simultaneous in-vivo measurements of both emissions that could be produced from a single or a combination of two different biomarkers. It also facilitates establishing the physical limitations of bioluminescence imaging, its tomographic and spectral image reconstruction potential and the quantification of bioluminescence signals.

  16. Multi-modality PET-CT imaging of breast cancer in an animal model using nanoparticle x-ray contrast agent and 18F-FDG

    NASA Astrophysics Data System (ADS)

    Badea, C. T.; Ghaghada, K.; Espinosa, G.; Strong, L.; Annapragada, A.

    2011-03-01

    Multi-modality PET-CT imaging is playing an important role in the field of oncology. While PET imaging facilitates functional interrogation of tumor status, the use of CT imaging is primarily limited to anatomical reference. In an attempt to extract comprehensive information about tumor cells and its microenvironment, we used a nanoparticle xray contrast agent to image tumor vasculature and vessel 'leakiness' and 18F-FDG to investigate the metabolic status of tumor cells. In vivo PET/CT studies were performed in mice implanted with 4T1 mammary breast cancer cells.Early-phase micro-CT imaging enabled visualization 3D vascular architecture of the tumors whereas delayedphase micro-CT demonstrated highly permeable vessels as evident by nanoparticle accumulation within the tumor. Both imaging modalities demonstrated the presence of a necrotic core as indicated by a hypo-enhanced region in the center of the tumor. At early time-points, the CT-derived fractional blood volume did not correlate with 18F-FDG uptake. At delayed time-points, the tumor enhancement in 18F-FDG micro-PET images correlated with the delayed signal enhanced due to nanoparticle extravasation seen in CT images. The proposed hybrid imaging approach could be used to better understand tumor angiogenesis and to be the basis for monitoring and evaluating anti-angiogenic and nano-chemotherapies.

  17. PET in oncology: will it replace the other modalities?

    PubMed

    Hoh, C K; Schiepers, C; Seltzer, M A; Gambhir, S S; Silverman, D H; Czernin, J; Maddahi, J; Phelps, M E

    1997-04-01

    Medical imaging technology is rapidly expanding and the role of each modality is being redefined constantly. PET has been around since the early sixties and gained clinical acceptance in oncology only after an extreme number of scientific publications. Although PET has the unique ability to image biochemical processes in vivo, this ability is not fully used as a clinical imaging tool. In this overview, the role of PET in relation to other tumor imaging modalities will be discussed and the reported results in the literature will be reviewed. In predicting the future of PET, technical improvements of other imaging modalities need to be dealt with. The fundamental physical principles for image formation with computed tomography (CT), ultrasound (US), magnetic resonance imaging (MRI), photon-emission tomography (PET), and single photon emission CT (SPECT) will not change. The potential variety of radiopharmaceuticals which may be developed is unlimited, however, and this provides nuclear imaging techniques with a significant advantage and adaptive features for future biologic imaging. The current applications of PET in oncology have been in characterizing tumor lesions, differentiating recurrent disease from treatment effects, staging tumors, evaluating the extent of disease, and monitoring therapy. The future developments in medicine may use the unique capabilities of PET not only in diagnostic imaging but also in molecular medicine and genetics. The articles discussed in this review were selected from a literature search covering the last 3 years, and in which comparisons of PET with conventional imaging were addressed specifically. PET studies with the glucose analogue fluorine-18-labeled deoxyglucose (FDG) have shown the ability of detecting tumor foci in a variety of histological neoplasms such as thyroid cancer, breast cancer, lymphoma, lung cancer, head and neck carcinoma, colorectal cancer, ovarian carcinoma, and musculoskeletal tumors. Also, the contribution

  18. 68Ga-labeled superparamagnetic iron oxide nanoparticles (SPIONs) for multi-modality PET/MR/Cherenkov luminescence imaging of sentinel lymph nodes

    PubMed Central

    Madru, Renata; Tran, Thuy A; Axelsson, Johan; Ingvar, Christian; Bibic, Adnan; Ståhlberg, Freddy; Knutsson, Linda; Strand, Sven-Erik

    2014-01-01

    The aim of this study was to develop 68Ga-SPIONs for use as a single contrast agent for dynamic, quantitative and high resolution PET/MR imaging of Sentinel Lymph Node (SLN). In addition 68Ga enables Cherenkov light emission which can be used for optical guidance during resection of SLN. SPIONs were labeled with 68Ga in ammonium acetate buffer, pH 5.5. The labeling yield and stability in human serum were determined using instant thin layer chromatography. An amount of 0.07-0.1 mL (~5-10 MBq, 0.13 mg Fe) of 68Ga-SPIONs was subcutaneously injected in the hind paw of rats. The animals were imaged at 0-3 h and 25 h post injection with PET/CT, 9.4 T MR and CCDbased Cherenkov optical systems. A biodistribution study was performed by dissecting and measuring the radioactivity in lymph nodes, kidneys, spleen, liver and the injection site. The labeling yield was 97.3 ± 0.05% after 15 min and the 68Ga-SPIONs were stable in human serum. PET, MR and Cherenkov luminescence imaging clearly visualized the SLN. Biodistribution confirmed a high uptake of the 68Ga-SPIONs within the SLN. We conclude that generator produced 68Ga can be labeled to SPIONs. Subcutaneously injected 68Ga-SPIONs can enhance the identification of the SLNs by combining sensitive PET and high resolution MR imaging. Clinically, hybrid PET/MR cameras are already in use and 68Ga-SPIONs have a great potential as a single-dose, tri-modality agent for diagnostic imaging and potential Cherenkov luminescent guided resection of SLN. PMID:24380046

  19. Dual-modality PET/CT instrumentation-today and tomorrow.

    PubMed

    Lonsdale, Markus Nowak; Beyer, Thomas

    2010-03-01

    Positron emission tomography (PET) has proven to be a clinically valuable imaging modality, particularly for oncology staging and therapy follow-up. The introduction of combined PET/CT imaging has helped address challenging imaging situations when anatomical information on PET-only was inadequate for accurate lesion localization. After a decade of PET/CT these combined systems have matured technically. Today, whole-body oncology staging is available with PET/CT in 15 min, or less. This review details recent developments in combined PET/CT instrumentation and points to implications for major applications in clinical oncology.

  20. Aluminium hydroxide stabilised MnFe2O4 and Fe3O4 nanoparticles as dual-modality contrasts agent for MRI and PET imaging.

    PubMed

    Cui, Xianjin; Belo, Salome; Krüger, Dirk; Yan, Yong; de Rosales, Rafael T M; Jauregui-Osoro, Maite; Ye, Haitao; Su, Shi; Mathe, Domokos; Kovács, Noémi; Horváth, Ildikó; Semjeni, Mariann; Sunassee, Kavitha; Szigeti, Krisztian; Green, Mark A; Blower, Philip J

    2014-07-01

    Magnetic nanoparticles (NPs) MnFe2O4 and Fe3O4 were stabilised by depositing an Al(OH)3 layer via a hydrolysis process. The particles displayed excellent colloidal stability in water and a high affinity to [(18)F]-fluoride and bisphosphonate groups. A high radiolabeling efficiency, 97% for (18)F-fluoride and 100% for (64)Cu-bisphosphonate conjugate, was achieved by simply incubating NPs with radioactivity solution at room temperature for 5 min. The properties of particles were strongly dependant on the thickness and hardness of the Al(OH)3 layer which could in turn be controlled by the hydrolysis method. The application of these Al(OH)3 coated magnetic NPs in molecular imaging has been further explored. The results demonstrated that these NPs are potential candidates as dual modal probes for MR and PET. In vivo PET imaging showed a slow release of (18)F from NPs, but no sign of efflux of (64)Cu.

  1. MULTIMODALITY IMAGING: BEYOND PET/CT AND SPECT/CT

    PubMed Central

    Cherry, Simon R.

    2009-01-01

    Multimodality imaging with PET/CT and SPECT/CT has become commonplace in clinical practice and in preclinical and basic medical research. Do other combinations of imaging modalities have a similar potential to impact medical science and clinical medicine? The combination of PET or SPECT with MRI is an area of active research at the present time, while other, perhaps less obvious combinations, including CT/MR and PET/optical also are being studied. In addition to the integration of the instrumentation, there are parallel developments in synthesizing imaging agents that can be viewed by multiple imaging modalities. Is the fusion of PET and SPECT with CT the ultimate answer in multimodality imaging, or is it just the first example of a more general trend towards harnessing the complementary nature of the different modalities on integrated imaging platforms? PMID:19646559

  2. PET Imaging of Angiogenesis

    PubMed Central

    Niu, Gang; Chen, Xiaoyuan

    2009-01-01

    Synopsis Angiogenesis is a highly-controlled process that is dependent on the intricate balance of both promoting and inhibiting factors, involved in various physiological and pathological processes. A comprehensive understanding of the molecular mechanisms that regulate angiogenesis has resulted in the design of new and more effective therapeutic strategies. Due to insufficient sensitivity to detect therapeutic effects by using standard clinical endpoints or by looking for physiological improvement, a multitude of imaging techniques have been developed to assess tissue vasculature on the structural, functional and molecular level. Imaging is expected to provide a novel approach to noninvasively monitor angiogenesis, to optimize the dose of new antiangiogenic agents and to assess the efficacy of therapies directed at modulation of the angiogenic process. All these methods have been successfully used preclinically and will hopefully aid in antiangiogenic drug development in animal studies. In this review article, the application of PET in angiogenesis imaging at both functional and molecular level will be discussed. For PET imaging of angiogenesis related molecular markers, we emphasize integrin αvβ3, VEGF/VEGFR, and MMPs. PMID:20046926

  3. Small-Animal PET Imaging of Amyloid-Beta Plaques with [11C]PiB and Its Multi-Modal Validation in an APP/PS1 Mouse Model of Alzheimer's Disease

    PubMed Central

    Manook, André; Yousefi, Behrooz H.; Willuweit, Antje; Platzer, Stefan; Reder, Sybille; Voss, Andreas; Huisman, Marc; Settles, Markus; Neff, Frauke; Velden, Joachim; Schoor, Michael; von der Kammer, Heinz; Wester, Hans-Jürgen; Schwaiger, Markus

    2012-01-01

    In vivo imaging and quantification of amyloid-β plaque (Aβ) burden in small-animal models of Alzheimer's disease (AD) is a valuable tool for translational research such as developing specific imaging markers and monitoring new therapy approaches. Methodological constraints such as image resolution of positron emission tomography (PET) and lack of suitable AD models have limited the feasibility of PET in mice. In this study, we evaluated a feasible protocol for PET imaging of Aβ in mouse brain with [11C]PiB and specific activities commonly used in human studies. In vivo mouse brain MRI for anatomical reference was acquired with a clinical 1.5 T system. A recently characterized APP/PS1 mouse was employed to measure Aβ at different disease stages in homozygous and hemizygous animals. We performed multi-modal cross-validations for the PET results with ex vivo and in vitro methodologies, including regional brain biodistribution, multi-label digital autoradiography, protein quantification with ELISA, fluorescence microscopy, semi-automated histological quantification and radioligand binding assays. Specific [11C]PiB uptake in individual brain regions with Aβ deposition was demonstrated and validated in all animals of the study cohort including homozygous AD animals as young as nine months. Corresponding to the extent of Aβ pathology, old homozygous AD animals (21 months) showed the highest uptake followed by old hemizygous (23 months) and young homozygous mice (9 months). In all AD age groups the cerebellum was shown to be suitable as an intracerebral reference region. PET results were cross-validated and consistent with all applied ex vivo and in vitro methodologies. The results confirm that the experimental setup for non-invasive [11C]PiB imaging of Aβ in the APP/PS1 mice provides a feasible, reproducible and robust protocol for small-animal Aβ imaging. It allows longitudinal imaging studies with follow-up periods of approximately one and a half years and

  4. PET Imaging - from Physics to Clinical Molecular Imaging

    NASA Astrophysics Data System (ADS)

    Majewski, Stan

    2008-03-01

    From the beginnings many years ago in a few physics laboratories and first applications as a research brain function imager, PET became lately a leading molecular imaging modality used in diagnosis, staging and therapy monitoring of cancer, as well as has increased use in assessment of brain function (early diagnosis of Alzheimer's, etc) and in cardiac function. To assist with anatomic structure map and with absorption correction CT is often used with PET in a duo system. Growing interest in the last 5-10 years in dedicated organ specific PET imagers (breast, prostate, brain, etc) presents again an opportunity to the particle physics instrumentation community to contribute to the important field of medical imaging. In addition to the bulky standard ring structures, compact, economical and high performance mobile imagers are being proposed and build. The latest development in standard PET imaging is introduction of the well known TOF concept enabling clearer tomographic pictures of the patient organs. Development and availability of novel photodetectors such as Silicon PMT immune to magnetic fields offers an exciting opportunity to use PET in conjunction with MRI and fMRI. As before with avalanche photodiodes, particle physics community plays a leading role in developing these devices. The presentation will mostly focus on present and future opportunities for better PET designs based on new technologies and methods: new scintillators, photodetectors, readout, software.

  5. Development of PET/MRI with insertable PET for simultaneous PET and MR imaging of human brain

    SciTech Connect

    Jung, Jin Ho; Choi, Yong Jung, Jiwoong; Kim, Sangsu; Lim, Hyun Keong; Im, Ki Chun; Oh, Chang Hyun; Park, Hyun-wook; Kim, Kyung Min; Kim, Jong Guk

    2015-05-15

    Purpose: The purpose of this study was to develop a dual-modality positron emission tomography (PET)/magnetic resonance imaging (MRI) with insertable PET for simultaneous PET and MR imaging of the human brain. Methods: The PET detector block was composed of a 4 × 4 matrix of detector modules, each consisting of a 4 × 4 array LYSO coupled to a 4 × 4 Geiger-mode avalanche photodiode (GAPD) array. The PET insert consisted of 18 detector blocks, circularly mounted on a custom-made plastic base to form a ring with an inner diameter of 390 mm and axial length of 60 mm. The PET gantry was shielded with gold-plated conductive fabric tapes with a thickness of 0.1 mm. The charge signals of PET detector transferred via 4 m long flat cables were fed into the position decoder circuit. The flat cables were shielded with a mesh-type aluminum sheet with a thickness of 0.24 mm. The position decoder circuit and field programmable gate array-embedded DAQ modules were enclosed in an aluminum box with a thickness of 10 mm and located at the rear of the MR bore inside the MRI room. A 3-T human MRI system with a Larmor frequency of 123.7 MHz and inner bore diameter of 60 cm was used as the PET/MRI hybrid system. A custom-made radio frequency (RF) coil with an inner diameter of 25 cm was fabricated. The PET was positioned between gradient and the RF coils. PET performance was measured outside and inside the MRI scanner using echo planar imaging, spin echo, turbo spin echo, and gradient echo sequences. MRI performance was also evaluated with and without the PET insert. The stability of the newly developed PET insert was evaluated and simultaneous PET and MR images of a brain phantom were acquired. Results: No significant degradation of the PET performance caused by MR was observed when the PET was operated using various MR imaging sequences. The signal-to-noise ratio of MR images was slightly degraded due to the PET insert installed inside the MR bore while the homogeneity was

  6. Imaging modalities in spinal disorders

    SciTech Connect

    Kricun, M.E.

    1986-01-01

    This book provides an approach to the various imaging modalities used to view the spine. It discusses the indications, limitations and practical use of each in the diagnosis, work-up and staging of various spinal disorders, and compares each of them in various clinical settings. Topics covered include low back pain syndrome, disk disease, spinal cord lesions, congenital abnormalities, and trauma.

  7. Exercises in PET Image Reconstruction

    NASA Astrophysics Data System (ADS)

    Nix, Oliver

    These exercises are complementary to the theoretical lectures about positron emission tomography (PET) image reconstruction. They aim at providing some hands on experience in PET image reconstruction and focus on demonstrating the different data preprocessing steps and reconstruction algorithms needed to obtain high quality PET images. Normalisation, geometric-, attenuation- and scatter correction are introduced. To explain the necessity of those some basics about PET scanner hardware, data acquisition and organisation are reviewed. During the course the students use a software application based on the STIR (software for tomographic image reconstruction) library 1,2 which allows them to dynamically select or deselect corrections and reconstruction methods as well as to modify their most important parameters. Following the guided tutorial, the students get an impression on the effect the individual data precorrections have on image quality and what happens if they are forgotten. Several data sets in sinogram format are provided, such as line source data, Jaszczak phantom data sets with high and low statistics and NEMA whole body phantom data. The two most frequently used reconstruction algorithms in PET image reconstruction, filtered back projection (FBP) and the iterative OSEM (ordered subset expectation maximation) approach are used to reconstruct images. The exercise should help the students gaining an understanding what the reasons for inferior image quality and artefacts are and how to improve quality by a clever choice of reconstruction parameters.

  8. Development of a PET Scanner for Simultaneously Imaging Small Animals with MRI and PET

    PubMed Central

    Thompson, Christopher J; Goertzen, Andrew L; Thiessen, Jonathan D; Bishop, Daryl; Stortz, Greg; Kozlowski, Piotr; Retière, Fabrice; Zhang, Xuezhu; Sossi, Vesna

    2014-01-01

    Recently, positron emission tomography (PET) is playing an increasingly important role in the diagnosis and staging of cancer. Combined PET and X-ray computed tomography (PET-CT) scanners are now the modality of choice in cancer treatment planning. More recently, the combination of PET and magnetic resonance imaging (MRI) is being explored in many sites. Combining PET and MRI has presented many challenges since the photo-multiplier tubes (PMT) in PET do not function in high magnetic fields, and conventional PET detectors distort MRI images. Solid state light sensors like avalanche photo-diodes (APDs) and more recently silicon photo-multipliers (SiPMs) are much less sensitive to magnetic fields thus easing the compatibility issues. This paper presents the results of a group of Canadian scientists who are developing a PET detector ring which fits inside a high field small animal MRI scanner with the goal of providing simultaneous PET and MRI images of small rodents used in pre-clinical medical research. We discuss the evolution of both the crystal blocks (which detect annihilation photons from positron decay) and the SiPM array performance in the last four years which together combine to deliver significant system performance in terms of speed, energy and timing resolution. PMID:25120157

  9. Automated cardiac motion compensation in PET/CT for accurate reconstruction of PET myocardial perfusion images

    NASA Astrophysics Data System (ADS)

    Khurshid, Khawar; McGough, Robert J.; Berger, Kevin

    2008-10-01

    Error-free reconstruction of PET data with a registered CT attenuation map is essential for accurate quantification and interpretation of cardiac perfusion. Misalignment of the CT and PET data can produce an erroneous attenuation map that projects lung attenuation parameters onto the heart wall, thereby underestimating the attenuation and creating artifactual areas of hypoperfusion that can be misinterpreted as myocardial ischemia or infarction. The major causes of misregistration between CT and PET images are the respiratory motion, cardiac motion and gross physical motion of the patient. The misalignment artifact problem is overcome with automated cardiac registration software that minimizes the alignment error between the two modalities. Results show that the automated registration process works equally well for any respiratory phase in which the CT scan is acquired. Further evaluation of this procedure on 50 patients demonstrates that the automated registration software consistently aligns the two modalities, eliminating artifactual hypoperfusion in reconstructed PET images due to PET/CT misregistration. With this registration software, only one CT scan is required for PET/CT imaging, which reduces the radiation dose required for CT-based attenuation correction and improves the clinical workflow for PET/CT.

  10. Contrast Media in PET/Computed Tomography Imaging.

    PubMed

    Dhull, Varun Singh; Rana, Neelima; Nazar, Aftab Hasan

    2016-01-01

    Is there a need for the contrast-enhanced PET/computed tomography (CT) scan or is the low-dose, non-contrast-enhanced PET/CT scan sufficient? The topic has been debated time and again. Although low-dose noncontrast CT serves the purpose of simple anatomic correlation and attenuation correction of PET images, many times patients have to undergo additional contrast-enhanced diagnostic imaging modalities, which may lead to a delay in decision-making. In this review, the authors have addressed various such issues related to the use of contrast agents and special techniques of clinical interest based on their utility in dual-modality PET/CT.

  11. PET Imaging in Huntington's Disease.

    PubMed

    Roussakis, Andreas-Antonios; Piccini, Paola

    2015-01-01

    To date, little is known about how neurodegeneration and neuroinflammation propagate in Huntington's disease (HD). Unfortunately, no treatment is available to cure or reverse the progressive decline of function caused by the disease, thus considering HD a fatal disease. Mutation gene carriers typically remain asymptomatic for many years although alterations in the basal ganglia and cortex occur early on in mutant HD gene-carriers. Positron Emission Tomography (PET) is a functional imaging technique of nuclear medicine which enables in vivo visualization of numerous biological molecules expressed in several human tissues. Brain PET is most powerful to study in vivo neuronal and glial cells function as well as cerebral blood flow in a plethora of neurodegenerative disorders including Parkinson's disease, Alzheimer's and HD. In absence of HD-specific biomarkers for monitoring disease progression, previous PET studies in HD were merely focused on the study of dopaminergic terminals, cerebral blood flow and glucose metabolism in manifest and premanifest HD-gene carriers. More recently, research interest has been exploring novel PET targets in HD including the state of phosphodiesterse expression and the role of activated microglia. Hence, a better understanding of the HD pathogenesis mechanisms may lead to the development of targeted therapies. PET imaging follow-up studies with novel selective PET radiotracers such as 11C-IMA-107 and 11C-PBR28 may provide insight on disease progression and identify prognostic biomarkers, elucidate the underlying HD pathology and assess novel pharmaceutical agents and over time.

  12. Diagnosis of bone metastasis: recent comparative studies of imaging modalities.

    PubMed

    Talbot, J N; Paycha, F; Balogova, S

    2011-08-01

    Various imaging modalities are currently available to diagnose bone metastasis. The two main anatomical modalities are computed tomography (CT) and magnetic resonance imaging (MRI), with many variants proposed for the MRI procedure, including diffusion-weighted imaging. The two main functional modalities are scintigraphy and PET, also with many variants in the radiopharmaceutical, from the "all purpose" 99mTc labelled bisphosphonates to very selective radiopharmaceuticals for rare neoplasia. The diagnostic strategy will become more and more individually tailored according to the patient's clinical and biological data (primary cancer type, phase of the evolution, markers of aggressiveness, serum levels of biological tracers of bone metabolism, circulating or disseminating tumour cells …). If imaging is indicated, the diagnostic strategy will also depend on the availability and the diagnostic performance of the imaging modalities. Assessment of diagnostic performance requires comparative studies, performed with an adequate methodology. The main methodological weaknesses encountered in studies intending to compare imaging modalities for diagnosing bone metastasis are summarised. Comparative studies have been reviewed, which address the initial diagnosis of skeletal metastases in solid tumours except primary bone cancers. The results of more than 140 such comparative studies are then summarised and briefly commented, according to the type of the primary cancer, and according to the compared imaging modalities.

  13. Image reconstruction for PET/CT scanners: past achievements and future challenges

    PubMed Central

    Tong, Shan; Alessio, Adam M; Kinahan, Paul E

    2011-01-01

    PET is a medical imaging modality with proven clinical value for disease diagnosis and treatment monitoring. The integration of PET and CT on modern scanners provides a synergy of the two imaging modalities. Through different mathematical algorithms, PET data can be reconstructed into the spatial distribution of the injected radiotracer. With dynamic imaging, kinetic parameters of specific biological processes can also be determined. Numerous efforts have been devoted to the development of PET image reconstruction methods over the last four decades, encompassing analytic and iterative reconstruction methods. This article provides an overview of the commonly used methods. Current challenges in PET image reconstruction include more accurate quantitation, TOF imaging, system modeling, motion correction and dynamic reconstruction. Advances in these aspects could enhance the use of PET/CT imaging in patient care and in clinical research studies of pathophysiology and therapeutic interventions. PMID:21339831

  14. On the accuracy of a mutual information algorithm for PET-MR image registration

    NASA Astrophysics Data System (ADS)

    Karaiskos, P.; Malamitsi, J.; Andreou, J.; Prassopoulos, V.; Valotassiou, V.; Laspas, F.; Sandilos, P.; Torrens, M.

    2009-07-01

    Image registration has been increasingly used in radiation diagnosis and treatment planning as a means of information integration from different imaging modalities (e.g. MRI, PET, CT). Especially for brain lesions, accurate 3D registration and fusion of MR and PET images can provide comprehensive information about the patient under study by relating functional information from PET images to the detailed anatomical information available in MR images. However, direct PET-MR image fusion in soft tissue is complicated mainly due to the lack of conspicuous anatomical features in PET images. This study describes the implementation and validation of a mutual information registration algorithm for this purpose. Ten patients with brain lesions underwent MR and PET/CT scanning. MR-PET registration was performed a) based on the well validated MR-CT registration technique and copying the transformation to the PET images derived from the PET/CT scan (MR/PET/CT registration method) and b) directly from the MR and PET images without taking into account the CT images (MR/PET registration method). In order to check the registration accuracy of the MR/PET method, the lesion (target) was contoured in the PET images and it was transferred to the MR images using both the above methods. The MR/PET/CT method served as the gold standard for target contouring. Target contours derived by the MR/PET method were compared with the gold standard target contours for each patient and the deviation between the two contours was used to estimate the accuracy of the PET-MR registration method. This deviation was less than 3 mm (i.e. comparable to the imaging voxel of the PET/CT scanning) for 9/10 of the cases studied. Results show that the mutual information algorithm used is able to perform the PET-MR registration reliably and accurately.

  15. Morphology supporting function: attenuation correction for SPECT/CT, PET/CT, and PET/MR imaging

    PubMed Central

    Lee, Tzu C.; Alessio, Adam M.; Miyaoka, Robert M.; Kinahan, Paul E.

    2017-01-01

    Both SPECT, and in particular PET, are unique in medical imaging for their high sensitivity and direct link to a physical quantity, i.e. radiotracer concentration. This gives PET and SPECT imaging unique capabilities for accurately monitoring disease activity for the purposes of clinical management or therapy development. However, to achieve a direct quantitative connection between the underlying radiotracer concentration and the reconstructed image values several confounding physical effects have to be estimated, notably photon attenuation and scatter. With the advent of dual-modality SPECT/CT, PET/CT, and PET/MR scanners, the complementary CT or MR image data can enable these corrections, although there are unique challenges for each combination. This review covers the basic physics underlying photon attenuation and scatter and summarizes technical considerations for multimodal imaging with regard to PET and SPECT quantification and methods to address the challenges for each multimodal combination. PMID:26576737

  16. Simultaneous acquisition of magnetic resonance spectroscopy (MRS) data and positron emission tomography (PET) images with a prototype MR-compatible, small animal PET imager

    NASA Astrophysics Data System (ADS)

    Raylman, Raymond R.; Majewski, Stan; Velan, S. Sendhil; Lemieux, Susan; Kross, Brian; Popov, Vladimir; Smith, Mark F.; Weisenberger, Andrew G.

    2007-06-01

    Multi-modality imaging (such as PET-CT) is rapidly becoming a valuable tool in the diagnosis of disease and in the development of new drugs. Functional images produced with PET, fused with anatomical images created by MRI, allow the correlation of form with function. Perhaps more exciting than the combination of anatomical MRI with PET, is the melding of PET with MR spectroscopy (MRS). Thus, two aspects of physiology could be combined in novel ways to produce new insights into the physiology of normal and pathological processes. Our team is developing a system to acquire MRI images and MRS spectra, and PET images contemporaneously. The prototype MR-compatible PET system consists of two opposed detector heads (appropriate in size for small animal imaging), operating in coincidence mode with an active field-of-view of ˜14 cm in diameter. Each detector consists of an array of LSO detector elements coupled through a 2-m long fiber optic light guide to a single position-sensitive photomultiplier tube. The use of light guides allows these magnetic field-sensitive elements of the PET imager to be positioned outside the strong magnetic field of our 3T MRI scanner. The PET scanner imager was integrated with a 12-cm diameter, 12-leg custom, birdcage coil. Simultaneous MRS spectra and PET images were successfully acquired from a multi-modality phantom consisting of a sphere filled with 17 brain relevant substances and a positron-emitting radionuclide. There were no significant changes in MRI or PET scanner performance when both were present in the MRI magnet bore. This successful initial test demonstrates the potential for using such a multi-modality to obtain complementary MRS and PET data.

  17. Dual-modal whole eye photoacoustic imaging

    NASA Astrophysics Data System (ADS)

    Wu, Ning; Ren, Qiushi; Li, Changhui

    2014-09-01

    We developed a prototype dual-modal ocular imaging system integrating optical-resolution photoacoustic microscopy and high-frequency ultrasound imaging modalities. This system can perform high-resolution ocular imaging from the anterior region down to the fundus area. The novel system successfully imaged the murine eyes in vivo, including iris, lens, retina, and retinal pigment epithelium. Our results demonstrated that this system has a great potential in the diagnosis of ophthalmic diseases.

  18. Simultaneous MRI and PET imaging of a rat brain

    NASA Astrophysics Data System (ADS)

    Raylman, Raymond R.; Majewski, Stan; Lemieux, Susan K.; Sendhil Velan, S.; Kross, Brian; Popov, Vladimir; Smith, Mark F.; Weisenberger, Andrew G.; Zorn, Carl; Marano, Gary D.

    2006-12-01

    Multi-modality imaging is rapidly becoming a valuable tool in the diagnosis of disease and in the development of new drugs. Functional images produced with PET fused with anatomical structure images created by MRI will allow the correlation of form with function. Our group is developing a system to acquire MRI and PET images contemporaneously. The prototype device consists of two opposed detector heads, operating in coincidence mode. Each MRI-PET detector module consists of an array of LSO detector elements coupled through a long fibre optic light guide to a single Hamamatsu flat panel position-sensitive photomultiplier tube (PSPMT). The use of light guides allows the PSPMTs to be positioned outside the bore of a 3T MRI scanner where the magnetic field is relatively small. To test the device, simultaneous MRI and PET images of the brain of a male Sprague Dawley rat injected with FDG were successfully obtained. The images revealed no noticeable artefacts in either image set. Future work includes the construction of a full ring PET scanner, improved light guides and construction of a specialized MRI coil to permit higher quality MRI imaging.

  19. Development of a PET/Cerenkov-light hybrid imaging system

    SciTech Connect

    Yamamoto, Seiichi Hamamura, Fuka; Kato, Katsuhiko; Ogata, Yoshimune; Watabe, Tadashi; Ikeda, Hayato; Kanai, Yasukazu; Hatazawa, Jun; Watabe, Hiroshi

    2014-09-15

    Purpose: Cerenkov-light imaging is a new molecular imaging technology that detects visible photons from high-speed electrons using a high sensitivity optical camera. However, the merit of Cerenkov-light imaging remains unclear. If a PET/Cerenkov-light hybrid imaging system were developed, the merit of Cerenkov-light imaging would be clarified by directly comparing these two imaging modalities. Methods: The authors developed and tested a PET/Cerenkov-light hybrid imaging system that consists of a dual-head PET system, a reflection mirror located above the subject, and a high sensitivity charge coupled device (CCD) camera. The authors installed these systems inside a black box for imaging the Cerenkov-light. The dual-head PET system employed a 1.2 × 1.2 × 10 mm{sup 3} GSO arranged in a 33 × 33 matrix that was optically coupled to a position sensitive photomultiplier tube to form a GSO block detector. The authors arranged two GSO block detectors 10 cm apart and positioned the subject between them. The Cerenkov-light above the subject is reflected by the mirror and changes its direction to the side of the PET system and is imaged by the high sensitivity CCD camera. Results: The dual-head PET system had a spatial resolution of ∼1.2 mm FWHM and sensitivity of ∼0.31% at the center of the FOV. The Cerenkov-light imaging system's spatial resolution was ∼275μm for a {sup 22}Na point source. Using the combined PET/Cerenkov-light hybrid imaging system, the authors successfully obtained fused images from simultaneously acquired images. The image distributions are sometimes different due to the light transmission and absorption in the body of the subject in the Cerenkov-light images. In simultaneous imaging of rat, the authors found that {sup 18}F-FDG accumulation was observed mainly in the Harderian gland on the PET image, while the distribution of Cerenkov-light was observed in the eyes. Conclusions: The authors conclude that their developed PET/Cerenkov-light hybrid

  20. Clinical Utility of Positron Emission Tomography Magnetic Resonance Imaging (PET-MRI) in Gastrointestinal Cancers.

    PubMed

    Matthews, Robert; Choi, Minsig

    2016-09-09

    Anatomic imaging utilizing both CT (computed tomography) and MRI (magnetic resonance imaging) limits the assessment of cancer metastases in lymph nodes and distant organs while functional imaging like PET (positron emission tomography) scan has its limitation in spatial resolution capacity. Hybrid imaging utilizing PET-CT and PET-MRI are novel imaging modalities that are changing the current landscape in cancer diagnosis, staging, and treatment response. MRI has shown to have higher sensitivity in soft tissue, head and neck pathology, and pelvic disease, as well as, detecting small metastases in the liver and bone compared to CT. Combining MRI with PET allows for detection of metastases that may have been missed with current imaging modalities. In this review, we will examine the clinical utility of FDG PET-MRI in the diagnosis and staging of gastrointestinal cancers with focus on esophageal, stomach, colorectal, and pancreatic cancers. We will also explore its role in treatment response and future directions associated with it.

  1. Registration of parametric dynamic F-18-FDG PET/CT breast images with parametric dynamic Gd-DTPA breast images

    NASA Astrophysics Data System (ADS)

    Magri, Alphonso; Krol, Andrzej; Lipson, Edward; Mandel, James; McGraw, Wendy; Lee, Wei; Tillapaugh-Fay, Gwen; Feiglin, David

    2009-02-01

    This study was undertaken to register 3D parametric breast images derived from Gd-DTPA MR and F-18-FDG PET/CT dynamic image series. Nonlinear curve fitting (Levenburg-Marquardt algorithm) based on realistic two-compartment models was performed voxel-by-voxel separately for MR (Brix) and PET (Patlak). PET dynamic series consists of 50 frames of 1-minute duration. Each consecutive PET image was nonrigidly registered to the first frame using a finite element method and fiducial skin markers. The 12 post-contrast MR images were nonrigidly registered to the precontrast frame using a free-form deformation (FFD) method. Parametric MR images were registered to parametric PET images via CT using FFD because the first PET time frame was acquired immediately after the CT image on a PET/CT scanner and is considered registered to the CT image. We conclude that nonrigid registration of PET and MR parametric images using CT data acquired during PET/CT scan and the FFD method resulted in their improved spatial coregistration. The success of this procedure was limited due to relatively large target registration error, TRE = 15.1+/-7.7 mm, as compared to spatial resolution of PET (6-7 mm), and swirling image artifacts created in MR parametric images by the FFD. Further refinement of nonrigid registration of PET and MR parametric images is necessary to enhance visualization and integration of complex diagnostic information provided by both modalities that will lead to improved diagnostic performance.

  2. Multivariate Chemical Image Fusion of Vibrational Spectroscopic Imaging Modalities.

    PubMed

    Gowen, Aoife A; Dorrepaal, Ronan M

    2016-07-02

    Chemical image fusion refers to the combination of chemical images from different modalities for improved characterisation of a sample. Challenges associated with existing approaches include: difficulties with imaging the same sample area or having identical pixels across microscopic modalities, lack of prior knowledge of sample composition and lack of knowledge regarding correlation between modalities for a given sample. In addition, the multivariate structure of chemical images is often overlooked when fusion is carried out. We address these challenges by proposing a framework for multivariate chemical image fusion of vibrational spectroscopic imaging modalities, demonstrating the approach for image registration, fusion and resolution enhancement of chemical images obtained with IR and Raman microscopy.

  3. Monitoring proton radiation therapy with in-room PET imaging.

    PubMed

    Zhu, Xuping; España, Samuel; Daartz, Juliane; Liebsch, Norbert; Ouyang, Jinsong; Paganetti, Harald; Bortfeld, Thomas R; El Fakhri, Georges

    2011-07-07

    We used a mobile positron emission tomography (PET) scanner positioned within the proton therapy treatment room to study the feasibility of proton range verification with an in-room, stand-alone PET system, and compared with off-line equivalent studies. Two subjects with adenoid cystic carcinoma were enrolled into a pilot study in which in-room PET scans were acquired in list-mode after a routine fractionated treatment session. The list-mode PET data were reconstructed with different time schemes to generate in-room short, in-room long and off-line equivalent (by skipping coincidences from the first 15 min during the list-mode reconstruction) PET images for comparison in activity distribution patterns. A phantom study was followed to evaluate the accuracy of range verification for different reconstruction time schemes quantitatively. The in-room PET has a higher sensitivity compared to the off-line modality so that the PET acquisition time can be greatly reduced from 30 to <5 min. Features in deep-site, soft-tissue regions were better retained with in-room short PET acquisitions because of the collection of (15)O component and lower biological washout. For soft tissue-equivalent material, the distal fall-off edge of an in-room short acquisition is deeper compared to an off-line equivalent scan, indicating a better coverage of the high-dose end of the beam. In-room PET is a promising low cost, high sensitivity modality for the in vivo verification of proton therapy. Better accuracy in Monte Carlo predictions, especially for biological decay modeling, is necessary.

  4. PSMA-Targeted Nano-Conjugates as Dual-Modality (MRI/PET) Imaging Probes for the Non-Invasive Detection of Prostate Cancer

    DTIC Science & Technology

    2009-10-01

    include, bare AuNPs, polymer-coated AuNPs, gadolinium -coated AuNPs and polymer-coated Bi2S3. Molecular CT imaging of cancer using targeted AuNPs in cell...magnetically labeled cells with either gadolinium or iron oxide nanoparticle based agents.1–7 With the much larger ∗Author to whom correspondence...T2) than traditional gadolinium - based contrast agents (T1). However iron oxide based T2 agents also exhibit the inherent weakness of MRI contrast

  5. TU-C-BRD-01: Image Guided SBRT I: Multi-Modality 4D Imaging

    SciTech Connect

    Cai, J; Mageras, G; Pan, T

    2014-06-15

    Motion management is one of the critical technical challenges for radiation therapy. 4D imaging has been rapidly adopted as essential tool to assess organ motion associated with respiratory breathing. A variety of 4D imaging techniques have been developed and are currently under development based on different imaging modalities such as CT, MRI, PET, and CBCT. Each modality provides specific and complementary information about organ and tumor respiratory motion. Effective use of each different technique or combined use of different techniques can introduce a comprehensive management of tumor motion. Specifically, these techniques have afforded tremendous opportunities to better define and delineate tumor volumes, more accurately perform patient positioning, and effectively apply highly conformal therapy techniques such as IMRT and SBRT. Successful implementation requires good understanding of not only each technique, including unique features, limitations, artifacts, imaging acquisition and process, but also how to systematically apply the information obtained from different imaging modalities using proper tools such as deformable image registration. Furthermore, it is important to understand the differences in the effects of breathing variation between different imaging modalities. A comprehensive motion management strategy using multi-modality 4D imaging has shown promise in improving patient care, but at the same time faces significant challenges. This session will focuses on the current status and advances in imaging respiration-induced organ motion with different imaging modalities: 4D-CT, 4D-MRI, 4D-PET, and 4D-CBCT/DTS. Learning Objectives: Understand the need and role of multimodality 4D imaging in radiation therapy. Understand the underlying physics behind each 4D imaging technique. Recognize the advantages and limitations of each 4D imaging technique.

  6. Quantitative simultaneous PET-MR imaging

    NASA Astrophysics Data System (ADS)

    Ouyang, Jinsong; Petibon, Yoann; Huang, Chuan; Reese, Timothy G.; Kolnick, Aleksandra L.; El Fakhri, Georges

    2014-06-01

    Whole-body PET is currently limited by the degradation due to patient motion. Respiratory motion degrades imaging studies of the abdomen. Similarly, both respiratory and cardiac motions significantly hamper the assessment of myocardial ischemia and/or metabolism in perfusion and viability cardiac PET studies. Based on simultaneous PET-MR, we have developed robust and accurate MRI methods allowing the tracking and measurement of both respiratory and cardiac motions during abdominal or cardiac studies. Our list-mode iterative PET reconstruction framework incorporates the measured motion fields into PET emission system matrix as well as the time-dependent PET attenuation map and the position dependent point spread function. Our method significantly enhances the PET image quality as compared to conventional methods.

  7. Optimal Co-segmentation of Tumor in PET-CT Images with Context Information

    PubMed Central

    Song, Qi; Bai, Junjie; Han, Dongfeng; Bhatia, Sudershan; Sun, Wenqing; Rockey, William; Bayouth, John E.; Buatti, John M.

    2014-01-01

    PET-CT images have been widely used in clinical practice for radiotherapy treatment planning of the radiotherapy. Many existing segmentation approaches only work for a single imaging modality, which suffer from the low spatial resolution in PET or low contrast in CT. In this work we propose a novel method for the co-segmentation of the tumor in both PET and CT images, which makes use of advantages from each modality: the functionality information from PET and the anatomical structure information from CT. The approach formulates the segmentation problem as a minimization problem of a Markov Random Field (MRF) model, which encodes the information from both modalities. The optimization is solved using a graph-cut based method. Two sub-graphs are constructed for the segmentation of the PET and the CT images, respectively. To achieve consistent results in two modalities, an adaptive context cost is enforced by adding context arcs between the two subgraphs. An optimal solution can be obtained by solving a single maximum flow problem, which leads to simultaneous segmentation of the tumor volumes in both modalities. The proposed algorithm was validated in robust delineation of lung tumors on 23 PET-CT datasets and two head-and-neck cancer subjects. Both qualitative and quantitative results show significant improvement compared to the graph cut methods solely using PET or CT. PMID:23693127

  8. PET/CT imaging in lung cancer: indications and findings*

    PubMed Central

    Hochhegger, Bruno; Alves, Giordano Rafael Tronco; Irion, Klaus Loureiro; Fritscher, Carlos Cezar; Fritscher, Leandro Genehr; Concatto, Natália Henz; Marchiori, Edson

    2015-01-01

    The use of PET/CT imaging in the work-up and management of patients with lung cancer has greatly increased in recent decades. The ability to combine functional and anatomical information has equipped PET/CT to look into various aspects of lung cancer, allowing more precise disease staging and providing useful data during the characterization of indeterminate pulmonary nodules. In addition, the accuracy of PET/CT has been shown to be greater than is that of conventional modalities in some scenarios, making PET/CT a valuable noninvasive method for the investigation of lung cancer. However, the interpretation of PET/CT findings presents numerous pitfalls and potential confounders. Therefore, it is imperative for pulmonologists and radiologists to familiarize themselves with the most relevant indications for and limitations of PET/CT, seeking to protect their patients from unnecessary radiation exposure and inappropriate treatment. This review article aimed to summarize the basic principles, indications, cancer staging considerations, and future applications related to the use of PET/CT in lung cancer. PMID:26176525

  9. Segmentation of brain PET-CT images based on adaptive use of complementary information

    NASA Astrophysics Data System (ADS)

    Xia, Yong; Wen, Lingfeng; Eberl, Stefan; Fulham, Michael; Feng, Dagan

    2009-02-01

    Dual modality PET-CT imaging provides aligned anatomical (CT) and functional (PET) images in a single scanning session, which can potentially be used to improve image segmentation of PET-CT data. The ability to distinguish structures for segmentation is a function of structure and modality and varies across voxels. Thus optimal contribution of a particular modality to segmentation is spatially variant. Existing segmentation algorithms, however, seldom account for this characteristic of PET-CT data and the results using these algorithms are not optimal. In this study, we propose a relative discrimination index (RDI) to characterize the relative abilities of PET and CT to correctly classify each voxel into the correct structure for segmentation. The definition of RDI is based on the information entropy of the probability distribution of the voxel's class label. If the class label derived from CT data for a particular voxel has more certainty than that derived from PET data, the corresponding RDI will have a higher value. We applied the RDI matrix to balance adaptively the contributions of PET and CT data to segmentation of brain PET-CT images on a voxel-by-voxel basis, with the aim to give the modality with higher discriminatory power a larger weight. The resultant segmentation approach is distinguished from traditional approaches by its innovative and adaptive use of the dual-modality information. We compared our approach to the non-RDI version and two commonly used PET-only based segmentation algorithms for simulation and clinical data. Our results show that the RDI matrix markedly improved PET-CT image segmentation.

  10. Proton Therapy Verification with PET Imaging

    PubMed Central

    Zhu, Xuping; Fakhri, Georges El

    2013-01-01

    Proton therapy is very sensitive to uncertainties introduced during treatment planning and dose delivery. PET imaging of proton induced positron emitter distributions is the only practical approach for in vivo, in situ verification of proton therapy. This article reviews the current status of proton therapy verification with PET imaging. The different data detecting systems (in-beam, in-room and off-line PET), calculation methods for the prediction of proton induced PET activity distributions, and approaches for data evaluation are discussed. PMID:24312147

  11. Multi-modality imaging of small animals

    NASA Astrophysics Data System (ADS)

    Kastis, Georgios Anthony

    Over the last few years there has been a great demand for noninvasive, dedicated, small-animal imaging systems for biomedical research applications. In this dissertation we will discuss the development and performance of two gamma-ray systems and a dual modality CT/SPECT system. Initially we introduce FASTSPECT, a stationary, scintillator-based, single-photon emission computed tomography (SPECT) system that was originally built as a brain imager. We discuss its transformation into a small-animal imaging system and validate its performance by presenting high-resolution images of phantoms and animals. Furthermore, we discuss the development of an in vivo imaging protocol for rat myocardial models using FASTSPECT. The infarct size obtained from the images is quantified and compared with the myocardial infarct size measured from histology. Semiconductor detectors can exhibit good spatial and energy resolution, and therefore offer a promising alternative to scintillation technology. We discuss the performance of a semiconductor detector system, previously developed in our group, for planar and tomographic imaging of small animals. The same gamma-ray detector is used in a dual modality system for imaging mice. The system combines an anatomical imaging modality, x-ray CT, with a functional modality, SPECT. We present the development of the CT/SPECT system and illustrate its performance by presenting high-resolution images of phantoms and mice. Finally, we introduce a procedure for evaluating estimation methods without the use of a gold standard.

  12. New SPECT and PET Radiopharmaceuticals for Imaging Cardiovascular Disease

    PubMed Central

    Sogbein, Oyebola O.; Pelletier-Galarneau, Matthieu; Schindler, Thomas H.; Wei, Lihui; Wells, R. Glenn; Ruddy, Terrence D.

    2014-01-01

    Nuclear cardiology has experienced exponential growth within the past four decades with converging capacity to diagnose and influence management of a variety of cardiovascular diseases. Single photon emission computed tomography (SPECT) myocardial perfusion imaging (MPI) with technetium-99m radiotracers or thallium-201 has dominated the field; however new hardware and software designs that optimize image quality with reduced radiation exposure are fuelling a resurgence of interest at the preclinical and clinical levels to expand beyond MPI. Other imaging modalities including positron emission tomography (PET) and magnetic resonance imaging (MRI) continue to emerge as powerful players with an expanded capacity to diagnose a variety of cardiac conditions. At the forefront of this resurgence is the development of novel target vectors based on an enhanced understanding of the underlying pathophysiological process in the subcellular domain. Molecular imaging with novel radiopharmaceuticals engineered to target a specific subcellular process has the capacity to improve diagnostic accuracy and deliver enhanced prognostic information to alter management. This paper, while not comprehensive, will review the recent advancements in radiotracer development for SPECT and PET MPI, autonomic dysfunction, apoptosis, atherosclerotic plaques, metabolism, and viability. The relevant radiochemistry and preclinical and clinical development in addition to molecular imaging with emerging modalities such as cardiac MRI and PET-MR will be discussed. PMID:24901002

  13. MO-FG-207-00: Technological Advances in PET/MR Imaging

    SciTech Connect

    2015-06-15

    The use of integrated PET/MRI systems in clinical applications can best benefit from understanding their technological advances and limitations. The currently available clinical PET/MRI systems have their own characteristics. Thorough analyses of existing technical data and evaluation of necessary performance metrics for quality assurances could be conducted to optimize application-specific PET/MRI protocols. This Symposium will focus on technical advances and limitations of clinical PET/MRI systems, and how this exciting imaging modality can be utilized in applications that can benefit from both PET and MRI. Learning Objectives: To understand the technological advances of clinical PET/MRI systems To correctly identify clinical applications that can benefit from PET/MRI To understand ongoing work to further improve the current PET/MRI technology Floris Jansen is a GE Healthcare employee.

  14. Instrumentation challenges in multi-modality imaging

    NASA Astrophysics Data System (ADS)

    Brasse, D.; Boisson, F.

    2016-02-01

    Based on different physical principles, imaging procedures currently used in both clinical and preclinical applications present different performance that allow researchers to achieve a large number of studies. However, the relevance of obtaining a maximum of information relating to the same subject is undeniable. The last two decades have thus seen the advent of a full-fledged research axis, the multimodal in vivo imaging. Whether from an instrumentation point of view, for medical research or the development of new probes, all these research works illustrate the growing interest of the scientific community for multimodal imaging, which can be approached with different backgrounds and perspectives from engineers to end-users point of views. In the present review, we discuss the multimodal imaging concept, which focuses not only on PET/CT and PET/MRI instrumentation but also on recent investigations of what could become a possible future in the field.

  15. Quantitative PET imaging with the 3T MR-BrainPET

    NASA Astrophysics Data System (ADS)

    Weirich, C.; Scheins, J.; Lohmann, P.; Tellmann, L.; Byars, L.; Michel, C.; Rota Kops, E.; Brenner, D.; Herzog, H.; Shah, N. J.

    2013-02-01

    The new hybrid imaging technology of MR-PET allows for simultaneous acquisition of versatile MRI contrasts and the quantitative metabolic imaging with PET. In order to achieve the quantification of PET images with minimal residual error the application of several corrections is crucial. In this work we present our results on quantification with the 3T MR BrainPET scanner.

  16. PET Imaging of Skeletal Metastases and Its Role in Personalizing Further Management.

    PubMed

    Mahajan, Abhishek; Azad, Gurdip Kaur; Cook, Gary J

    2016-07-01

    In oncology, the skeleton is one of the most frequently encountered sites for metastatic disease and thus early detection not only has an impact on an individual patient's management but also on the overall outcome. Multiparametric and multimodal hybrid PET/computed tomography and PET/MR imaging have revolutionized imaging for bone metastases, but irrespective of tumor biology or morphology of the bone lesion it remains unclear which imaging modality is the most clinically relevant to guide individualized cancer care. In this review, we highlight the current clinical challenges of PET imaging in evaluation and quantification of skeletal tumor burden and its impact on personalized cancer management.

  17. Results from the commissioning of a multi-modal endoscope for ultrasound and time of flight PET

    SciTech Connect

    Bugalho, Ricardo

    2015-07-01

    The EndoTOFPET-US collaboration has developed a multi-modal imaging system combining Ultrasound with Time-of-Flight Positron Emission Tomography into an endoscopic imaging device. The objective of the project is to obtain a coincidence time resolution of about 200 ps FWHM and to achieve about 1 mm spatial resolution of the PET system, while integrating all the components in a very compact detector suitable for endoscopic use. This scanner aims to be exploited for diagnostic and surgical oncology, as well as being instrumental in the clinical test of new biomarkers especially targeted for prostate and pancreatic cancer. (authors)

  18. Gallium-68 EDTA PET/CT for Renal Imaging.

    PubMed

    Hofman, Michael S; Hicks, Rodney J

    2016-09-01

    Nuclear medicine renal imaging provides important functional data to assist in the diagnosis and management of patients with a variety of renal disorders. Physiologically stable metal chelates like ethylenediaminetetraacetic acid (EDTA) and diethylenetriamine penta-acetate (DTPA) are excreted by glomerular filtration and have been radiolabelled with a variety of isotopes for imaging glomerular filtration and quantitative assessment of glomerular filtration rate. Gallium-68 ((68)Ga) EDTA PET usage predates Technetium-99m ((99m)Tc) renal imaging, but virtually disappeared with the widespread adoption of gamma camera technology that was not optimal for imaging positron decay. There is now a reemergence of interest in (68)Ga owing to the greater availability of PET technology and use of (68)Ga to label other radiotracers. (68)Ga EDTA can be used a substitute for (99m)Tc DTPA for wide variety of clinical indications. A key advantage of PET for renal imaging over conventional scintigraphy is 3-dimensional dynamic imaging, which is particularly helpful in patients with complex anatomy in whom planar imaging may be nondiagnostic or difficult to interpret owing to overlying structures containing radioactive urine that cannot be differentiated. Other advantages include accurate and absolute (rather than relative) camera-based quantification, superior spatial and temporal resolution and integrated multislice CT providing anatomical correlation. Furthermore, the (68)Ga generator enables on-demand production at low cost, with no additional patient radiation exposure compared with conventional scintigraphy. Over the past decade, we have employed (68)Ga EDTA PET/CT primarily to answer difficult clinical questions in patients in whom other modalities have failed, particularly when it was envisaged that dynamic 3D imaging would be of assistance. We have also used it as a substitute for (99m)Tc DTPA if unavailable owing to supply issues, and have additionally examined the role of

  19. (18)F-NaF PET/CT: EANM procedure guidelines for bone imaging.

    PubMed

    Beheshti, M; Mottaghy, F M; Payche, F; Behrendt, F F F; Van den Wyngaert, T; Fogelman, I; Strobel, K; Celli, M; Fanti, S; Giammarile, F; Krause, B; Langsteger, W

    2015-10-01

    The aim of this guideline is to provide minimum standards for the performance and interpretation of (18)F-NaF PET/CT scans. Standard acquisition and interpretation of nuclear imaging modalities will help to provide consistent data acquisition and numeric values between different platforms and institutes and to promote the use of PET/CT modality as an established diagnostic modality in routine clinical practice. This will also improve the value of scientific work and its contribution to evidence-based medicine.

  20. PET and SPECT imaging in veterinary medicine.

    PubMed

    LeBlanc, Amy K; Peremans, Kathelijne

    2014-01-01

    Veterinarians have gained increasing access to positron emission tomography (PET and PET/CT) imaging facilities, allowing them to use this powerful molecular imaging technique for clinical and research applications. SPECT is currently being used more in Europe than in the United States and has been shown to be useful in veterinary oncology and in the evaluation of orthopedic diseases. SPECT brain perfusion and receptor imaging is used to investigate behavioral disorders in animals that have interesting similarities to human psychiatric disorders. This article provides an overview of the potential applications of PET and SPECT. The use of commercially available and investigational PET radiopharmaceuticals in the management of veterinary disease has been discussed. To date, most of the work in this field has utilized the commercially available PET tracer, (18)F-fluorodeoxyglucose for oncologic imaging. Normal biodistribution studies in several companion animal species (cats, dogs, and birds) have been published to assist in lesion detection and interpretation for veterinary radiologists and clinicians. Studies evaluating other (18)F-labeled tracers for research applications are underway at several institutions and companion animal models of human diseases are being increasingly recognized for their value in biomarker and therapy development. Although PET and SPECT technologies are in their infancy for clinical veterinary medicine, increasing access to and interest in these applications and other molecular imaging techniques has led to a greater knowledge and collective body of expertise for veterinarians worldwide. Initiation and fostering of physician-veterinarian collaborations are key components to the forward movement of this field.

  1. Initial tests of a prototype MRI-compatible PET imager

    NASA Astrophysics Data System (ADS)

    Raylman, Raymond R.; Majewski, Stan; Lemieux, Susan; Velan, S. Sendhil; Kross, Brain; Popov, Vladimir; Smith, Mark F.; Weisenberger, Andrew G.; Wojcik, Randy

    2006-12-01

    Multi-modality imaging is rapidly becoming a valuable tool in the diagnosis of disease and in the development of new drugs. Functional images produced with PET fused with anatomical structure images created by MRI, will allow the correlation of form with function. Our group (a collaboration of West Virginia University and Jefferson Lab) is developing a system to acquire MRI and PET images contemporaneously. The prototype device consists of two opposed detector heads, operating in coincidence mode with an active FOV of 5×5×4 cm 3. Each MRI-PET detector module consists of an array of LSO detector elements (2.5×2.5×15 mm 3) coupled through a long fiber optic light guide to a single Hamamatsu flat panel PSPMT. The fiber optic light guide is made of a glued assembly of 2 mm diameter acrylic fibers with a total length of 2.5 m. The use of a light guides allows the PSPMTs to be positioned outside the bore of the 3 T General Electric MRI scanner used in the tests. Photon attenuation in the light guides resulted in an energy resolution of ˜60% FWHM, interaction of the magnetic field with PSPMT further reduced energy resolution to ˜85% FWHM. Despite this effect, excellent multi-plane PET and MRI images of a simple disk phantom were acquired simultaneously. Future work includes improved light guides, optimized magnetic shielding for the PSPMTs, construction of specialized coils to permit high-resolution MRI imaging, and use of the system to perform simultaneous PET and MRI or MR-spectroscopy .

  2. LOR-interleaving image reconstruction for PET imaging with fractional-crystal collimation

    NASA Astrophysics Data System (ADS)

    Li, Yusheng; Matej, Samuel; Karp, Joel S.; Metzler, Scott D.

    2015-01-01

    Positron emission tomography (PET) has become an important modality in medical and molecular imaging. However, in most PET applications, the resolution is still mainly limited by the physical crystal sizes or the detector’s intrinsic spatial resolution. To achieve images with better spatial resolution in a central region of interest (ROI), we have previously proposed using collimation in PET scanners. The collimator is designed to partially mask detector crystals to detect lines of response (LORs) within fractional crystals. A sequence of collimator-encoded LORs is measured with different collimation configurations. This novel collimated scanner geometry makes the reconstruction problem challenging, as both detector and collimator effects need to be modeled to reconstruct high-resolution images from collimated LORs. In this paper, we present a LOR-interleaving (LORI) algorithm, which incorporates these effects and has the advantage of reusing existing reconstruction software, to reconstruct high-resolution images for PET with fractional-crystal collimation. We also develop a 3D ray-tracing model incorporating both the collimator and crystal penetration for simulations and reconstructions of the collimated PET. By registering the collimator-encoded LORs with the collimator configurations, high-resolution LORs are restored based on the modeled transfer matrices using the non-negative least-squares method and EM algorithm. The resolution-enhanced images are then reconstructed from the high-resolution LORs using the MLEM or OSEM algorithm. For validation, we applied the LORI method to a small-animal PET scanner, A-PET, with a specially designed collimator. We demonstrate through simulated reconstructions with a hot-rod phantom and MOBY phantom that the LORI reconstructions can substantially improve spatial resolution and quantification compared to the uncollimated reconstructions. The LORI algorithm is crucial to improve overall image quality of collimated PET, which

  3. LOR-interleaving image reconstruction for PET imaging with fractional-crystal collimation

    PubMed Central

    Li, Yusheng; Matej, Samuel; Karp, Joel S.; Metzler, Scott D.

    2015-01-01

    Positron emission tomography (PET) has become an important modality in medical and molecular imaging. However, in most PET applications, the resolution is still mainly limited by the physical crystal sizes or the detector’s intrinsic spatial resolution. To achieve images with better spatial resolution in a central region of interest (ROI), we have previously proposed using collimation in PET scanner. The collimator is designed to partially mask detector crystals to detect lines of response (LORs) within fractional crystals. A sequence of collimator-encoded LORs is measured with different collimation configurations. This novel collimated scanner geometry makes the reconstruction problem challenging, as both detector and collimator effects need to be modeled to reconstruct high-resolution images from collimated LORs. In this paper, we present an LOR-interleaving (LORI) algorithm, which incorporates these effects and has the advantage of reusing existing reconstruction software, to reconstruct high-resolution images for PET with fractional-crystal collimation. We also develop a 3-D ray-tracing model incorporating both the collimator and crystal penetration for simulations and reconstructions of the collimated PET. By registering the collimator-encoded LORs with the collimator configurations, high-resolution LORs are restored based on the modeled transfer matrices using the nonnegative least-squares method and EM algorithm. The resolution-enhanced images are then reconstructed from the high-resolution LORs using the MLEM or OSEM algorithm. For validation, we applied the LORI method to a small-animal PET scanner, A-PET, with a specially designed collimator. We demonstrate through simulated reconstructions with a hot-rod phantom and MOBY phantom that the LORI reconstructions can substantially improve spatial resolution and quantification compared to the uncollimated reconstructions. The LORI algorithm is crucial to improve overall image quality of collimated PET, which

  4. Novel Developments in Instrumentation for PET Imaging

    NASA Astrophysics Data System (ADS)

    Karp, Joel

    2013-04-01

    Advances in medical imaging, in particular positron emission tomography (PET), have been based on technical developments in physics and instrumentation that have common foundations with detection systems used in other fields of physics. New detector materials are used in PET systems that maximize efficiency, timing characteristics and robustness, and which lead to improved image quality and quantitative accuracy for clinical imaging. Time of flight (TOF) techniques are now routinely used in commercial PET scanners that combine physiological imaging with anatomical imaging provided by x-ray computed tomography. Using new solid-state photo-sensors instead of traditional photo-multiplier tubes makes it possible to combine PET with magnetic resonance imaging which is a significant technical challenge, but one that is creating new opportunities for both research and clinical applications. An overview of recent advances in instrumentation, such as TOF and PET/MR will be presented, along with examples of imaging studies to demonstrate the impact on patient care and basic research of diseases.

  5. PET Imaging of Skull Base Neoplasms.

    PubMed

    Mittra, Erik S; Iagaru, Andrei; Quon, Andrew; Fischbein, Nancy

    2007-10-01

    The utility of 18-F-fluorodeoxyglucose-positron emission tomography (PET) and PET/CT for the evaluation of skull base tumors is incompletely investigated, as a limited number of studies specifically focus on this region with regard to PET imaging. Several patterns can be ascertained, however, by synthesizing the data from various published reports and cases of primary skull base malignancies, as well as head and neck malignancies that extend secondarily to the skull base, including nasopharyngeal carcinoma, nasal cavity and paranasal sinus tumors, parotid cancers, and orbital tumors.

  6. Nanogels as imaging agents for modalities spanning the electromagnetic spectrum

    PubMed Central

    Chan, Minnie

    2016-01-01

    In the past few decades, advances in imaging equipment and protocols have expanded the role of imaging in in vivo diagnosis and disease management, especially in cancer. Traditional imaging agents have rapid clearance and low specificity for disease detection. To improve accuracy in disease identification, localization and assessment, novel nanomaterials are frequently explored as imaging agents to achieve high detection specificity and sensitivity. A promising material for this purpose are hydrogel nanoparticles, whose high hydrophilicity, biocompatibility, and tunable size in the nanometer range make them ideal for imaging. These nanogels (10 to 200 nm) can circumvent uptake by the reticuloendothelial system, allowing longer circulation times than small molecules. In addition, their size/surface properties can be further tailored to optimize their pharmacokinetics for imaging of a particular disease. Herein, we provide a comprehensive review of nanogels as imaging agents in various modalities with sources of signal spanning the electromagnetic spectrum, including MRI, NIR, UV-vis, and PET. Many materials and formulation methods will be reviewed to highlight the versatility of nanogels as imaging agents. PMID:27398218

  7. Nanogels as imaging agents for modalities spanning the electromagnetic spectrum.

    PubMed

    Chan, Minnie; Almutairi, Adah

    2016-01-21

    In the past few decades, advances in imaging equipment and protocols have expanded the role of imaging in in vivo diagnosis and disease management, especially in cancer. Traditional imaging agents have rapid clearance and low specificity for disease detection. To improve accuracy in disease identification, localization and assessment, novel nanomaterials are frequently explored as imaging agents to achieve high detection specificity and sensitivity. A promising material for this purpose are hydrogel nanoparticles, whose high hydrophilicity, biocompatibility, and tunable size in the nanometer range make them ideal for imaging. These nanogels (10 to 200 nm) can circumvent uptake by the reticuloendothelial system, allowing longer circulation times than small molecules. In addition, their size/surface properties can be further tailored to optimize their pharmacokinetics for imaging of a particular disease. Herein, we provide a comprehensive review of nanogels as imaging agents in various modalities with sources of signal spanning the electromagnetic spectrum, including MRI, NIR, UV-vis, and PET. Many materials and formulation methods will be reviewed to highlight the versatility of nanogels as imaging agents.

  8. Tri-modality small animal imaging system

    SciTech Connect

    Kundu, B.K.; Stolin, A.V.; Pole, J.; Baumgart, L.; Fontaine, M.; Wojcik, R.; Kross, B.; Zorn, C.; Majewski, S.; Williams, M.B.

    2006-02-01

    Our group is developing a scanner that combines x-ray, single gamma, and optical imaging on the same rotating gantry. Two functional modalities (SPECT and optical) are included because they have different strengths and weaknesses in terms of spatial and temporal decay lengths in the context of in vivo imaging, and because of the recent advent of multiple reporter gene constructs. The effect of attenuation by biological tissue on the detected intensity of the emitted signal was measured for both gamma and optical imaging. Attenuation by biological tissue was quantified for both the bioluminescent emission of luciferace and for the emission light of the near infrared fluorophore cyanine 5.5, using a fixed excitation light intensity. Experiments were performed to test the feasibility of using either single gamma or x-ray imaging to make depth-dependent corrections to the measured optical signal. Our results suggest that significant improvements in quantitation of optical emission are possible using straightforward correction techniques based on information from other modalities. Development of an integrated scanner in which data from each modality are obtained with the animal in a common configuration will greatly simplify this process.

  9. Modular Strategies for PET Imaging Agents

    PubMed Central

    Hooker, Jacob M

    2009-01-01

    Summary of Recent Advances In recent years, modular and simplified chemical and biological strategies have been developed for the synthesis and implementation of positron emission tomography (PET) radiotracers. New developments in bioconjugation and synthetic methodologies, in combination with advances in macromolecular delivery systems and gene-expression imaging, reflect a need to reduce radiosynthesis burden in order to accelerate imaging agent development. These new approaches, which are often mindful of existing infrastructure and available resources, are anticipated to provide a more approachable entry point for researchers interested in using PET to translate in vitro research to in vivo imaging. PMID:19880343

  10. Hybrid PET/MR Imaging and Brain Connectivity

    PubMed Central

    Aiello, Marco; Cavaliere, Carlo; Salvatore, Marco

    2016-01-01

    In recent years, brain connectivity is gaining ever-increasing interest from the interdisciplinary research community. The study of brain connectivity is characterized by a multifaceted approach providing both structural and functional evidence of the relationship between cerebral regions at different scales. Although magnetic resonance (MR) is the most established imaging modality for investigating connectivity in vivo, the recent advent of hybrid positron emission tomography (PET)/MR scanners paved the way for more comprehensive investigation of brain organization and physiology. Due to the high sensitivity and biochemical specificity of radiotracers, combining MR with PET imaging may enrich our ability to investigate connectivity by introducing the concept of metabolic connectivity and cometomics and promoting new insights on the physiological and molecular bases underlying high-level neural organization. This review aims to describe and summarize the main methods of analysis of brain connectivity employed in MR imaging and nuclear medicine. Moreover, it will discuss practical aspects and state-of-the-art techniques for exploiting hybrid PET/MR imaging to investigate the relationship of physiological processes and brain connectivity. PMID:26973446

  11. PET imaging of primary mediastinal tumours.

    PubMed Central

    Kubota, K.; Yamada, S.; Kondo, T.; Yamada, K.; Fukuda, H.; Fujiwara, T.; Ito, M.; Ido, T.

    1996-01-01

    Mediastinal masses include a wide variety of tumours and remain an interesting diagnostic challenge for radiologist. We performed positron emission tomography (PET) studies of primary mediastinal tumours in order to predict the malignancy of these tumours preoperatively. Twenty-two patients with primary mediastinal tumours were studied with PET using 2-deoxy-2-[18F]fluoro-D-glucose (FDG). The histological findings of surgical pathology or biopsy, or mediastinoscopy were compared with those of computerised tomography (CT) and PET. PET images were evaluated semiquantitatively using the differential uptake ratio (DUR). Increased FDG uptake was observed in nine of ten patients with malignant tumours, including thymic carcinomas, lymphomas, invasive thymomas and a case of sarcoidosis. A moderate level of FDG uptake was found in a myeloma, non-invasive thymomas, and a schwannoma, whereas a low uptake was observed in a teratoma and various benign cysts. The mean FDG uptake of malignant tumours was significantly higher than that of benign tumours. Both thymic cancer and invasive thymoma showed a high FDG uptake. CT examination resulted in three false-negative and two false-positive cases when used in predicting tumour invasion, while PET was associated with a false-positive and a false-negative case. In conclusion, the use of FDG with PET is clinically helpful in evaluating the malignant nature of primary mediastinal tumours. Our results also suggest that a high FDG uptake reflects the invasiveness of malignant nature of thymic tumours. Images Figure 1 Figure 2 PMID:8611400

  12. Monte Carlo simulations of medical imaging modalities

    SciTech Connect

    Estes, G.P.

    1998-09-01

    Because continuous-energy Monte Carlo radiation transport calculations can be nearly exact simulations of physical reality (within data limitations, geometric approximations, transport algorithms, etc.), it follows that one should be able to closely approximate the results of many experiments from first-principles computations. This line of reasoning has led to various MCNP studies that involve simulations of medical imaging modalities and other visualization methods such as radiography, Anger camera, computerized tomography (CT) scans, and SABRINA particle track visualization. It is the intent of this paper to summarize some of these imaging simulations in the hope of stimulating further work, especially as computer power increases. Improved interpretation and prediction of medical images should ultimately lead to enhanced medical treatments. It is also reasonable to assume that such computations could be used to design new or more effective imaging instruments.

  13. Respiration-Averaged CT for Attenuation Correction of PET Images – Impact on PET Texture Features in Non-Small Cell Lung Cancer Patients

    PubMed Central

    Cheng, Nai-Ming; Fang, Yu-Hua Dean; Tsan, Din-Li

    2016-01-01

    Purpose We compared attenuation correction of PET images with helical CT (PET/HCT) and respiration-averaged CT (PET/ACT) in patients with non-small-cell lung cancer (NSCLC) with the goal of investigating the impact of respiration-averaged CT on 18F FDG PET texture parameters. Materials and Methods A total of 56 patients were enrolled. Tumors were segmented on pretreatment PET images using the adaptive threshold. Twelve different texture parameters were computed: standard uptake value (SUV) entropy, uniformity, entropy, dissimilarity, homogeneity, coarseness, busyness, contrast, complexity, grey-level nonuniformity, zone-size nonuniformity, and high grey-level large zone emphasis. Comparisons of PET/HCT and PET/ACT were performed using Wilcoxon signed-rank tests, intraclass correlation coefficients, and Bland-Altman analysis. Receiver operating characteristic (ROC) curves as well as univariate and multivariate Cox regression analyses were used to identify the parameters significantly associated with disease-specific survival (DSS). A fixed threshold at 45% of the maximum SUV (T45) was used for validation. Results SUV maximum and total lesion glycolysis (TLG) were significantly higher in PET/ACT. However, texture parameters obtained with PET/ACT and PET/HCT showed a high degree of agreement. The lowest levels of variation between the two modalities were observed for SUV entropy (9.7%) and entropy (9.8%). SUV entropy, entropy, and coarseness from both PET/ACT and PET/HCT were significantly associated with DSS. Validation analyses using T45 confirmed the usefulness of SUV entropy and entropy in both PET/HCT and PET/ACT for the prediction of DSS, but only coarseness from PET/ACT achieved the statistical significance threshold. Conclusions Our results indicate that 1) texture parameters from PET/ACT are clinically useful in the prediction of survival in NSCLC patients and 2) SUV entropy and entropy are robust to attenuation correction methods. PMID:26930211

  14. Diagnosing cardiac disease during pregnancy: imaging modalities.

    PubMed

    Ntusi, Ntobeko A; Samuels, Petronella; Moosa, Sulaiman; Mocumbi, Ana O

    2016-01-01

    Pregnant women with known or suspected cardiovascular disease (CVD) often require cardiovascular imaging during pregnancy. The accepted maximum limit of ionising radiation exposure to the foetus during pregnancy is a cumulative dose of 5 rad. Concerns related to imaging modalities that involve ionising radiation include teratogenesis, mutagenesis and childhood malignancy. Importantly, no single imaging study approaches this cautionary dose of 5 rad (50 mSv or 50 mGy). Diagnostic imaging procedures that may be used in pregnancy include chest radiography, fluoroscopy, echocardiography, invasive angiography, cardiovascular computed tomography, computed tomographic pulmonary angiography, cardiovascular magnetic resonance (CMR) and nuclear techniques. Echocardiography and CMR appear to be completely safe in pregnancy and are not associated with any adverse foetal effects, provided there are no general contra-indications to MR imaging. Concerns related to safety of imaging tests must be balanced against the importance of accurate diagnosis and thorough assessment of the pathological condition. Decisions about imaging in pregnancy are premised on understanding the physiology of pregnancy, understanding basic concepts of ionising radiation, the clinical manifestations of existent CVD in pregnancy and features of new CVD. The cardiologist/physician must understand the indications for and limitations of, and the potential harmful effects of each test during pregnancy. Current evidence suggests that a single cardiovascular radiological study during pregnancy is safe and should be undertaken at all times when clinically justified. In this article, the different imaging modalities are reviewed in terms of how they work, how safe they are and what their clinical utility in pregnancy is. Furthermore, the safety of contrast agents in pregnancy is also reviewed.

  15. Advanced Imaging Modalities in the Detection of Cerebral Vasospasm

    PubMed Central

    Mills, Jena N.; Mehta, Vivek; Russin, Jonathan; Amar, Arun P.; Rajamohan, Anandh; Mack, William J.

    2013-01-01

    The pathophysiology of cerebral vasospasm following aneurysmal subarachnoid hemorrhage (SAH) is complex and is not entirely understood. Mechanistic insights have been gained through advances in the capabilities of diagnostic imaging. Core techniques have focused on the assessment of vessel caliber, tissue metabolism, and/or regional perfusion parameters. Advances in imaging have provided clinicians with a multifaceted approach to assist in the detection of cerebral vasospasm and the diagnosis of delayed ischemic neurologic deficits (DIND). However, a single test or algorithm with broad efficacy remains elusive. This paper examines both anatomical and physiological imaging modalities applicable to post-SAH vasospasm and offers a historical background. We consider cerebral blood flow velocities measured by Transcranial Doppler Ultrasonography (TCD). Structural imaging techniques, including catheter-based Digital Subtraction Angiography (DSA), CT Angiography (CTA), and MR Angiography (MRA), are reviewed. We examine physiologic assessment by PET, HMPAO SPECT, 133Xe Clearance, Xenon-Enhanced CT (Xe/CT), Perfusion CT (PCT), and Diffusion-Weighted/MR Perfusion Imaging. Comparative advantages and limitations are discussed. PMID:23476766

  16. PET-based molecular imaging in neuroscience.

    PubMed

    Jacobs, A H; Li, H; Winkeler, A; Hilker, R; Knoess, C; Rüger, A; Galldiks, N; Schaller, B; Sobesky, J; Kracht, L; Monfared, P; Klein, M; Vollmar, S; Bauer, B; Wagner, R; Graf, R; Wienhard, K; Herholz, K; Heiss, W D

    2003-07-01

    Positron emission tomography (PET) allows non-invasive assessment of physiological, metabolic and molecular processes in humans and animals in vivo. Advances in detector technology have led to a considerable improvement in the spatial resolution of PET (1-2 mm), enabling for the first time investigations in small experimental animals such as mice. With the developments in radiochemistry and tracer technology, a variety of endogenously expressed and exogenously introduced genes can be analysed by PET. This opens up the exciting and rapidly evolving field of molecular imaging, aiming at the non-invasive localisation of a biological process of interest in normal and diseased cells in animal models and humans in vivo. The main and most intriguing advantage of molecular imaging is the kinetic analysis of a given molecular event in the same experimental subject over time. This will allow non-invasive characterisation and "phenotyping" of animal models of human disease at various disease stages, under certain pathophysiological stimuli and after therapeutic intervention. The potential broad applications of imaging molecular events in vivo lie in the study of cell biology, biochemistry, gene/protein function and regulation, signal transduction, transcriptional regulation and characterisation of transgenic animals. Most importantly, molecular imaging will have great implications for the identification of potential molecular therapeutic targets, in the development of new treatment strategies, and in their successful implementation into clinical application. Here, the potential impact of molecular imaging by PET in applications in neuroscience research with a special focus on neurodegeneration and neuro-oncology is reviewed.

  17. Modality-Invariant Image Classification Based on Modality Uniqueness and Dictionary Learning.

    PubMed

    Kim, Seungryong; Cai, Rui; Park, Kihong; Kim, Sunok; Sohn, Kwanghoon

    2016-12-02

    We present a unified framework for image classification of image sets taken under varying modality conditions. Our method is motivated by a key observation that the image feature distribution is simultaneously influenced by the semantic-class and the modality category label, which limits the performance of conventional methods for that task. With this insight, we introduce modality uniqueness as a discriminative weight that divides each modality cluster from all other clusters. By leveraging the modality uniqueness, our framework is formulated as unsupervised modality clustering and classifier learning based on modality-invariant similarity kernel. Specifically, in the assignment step, each training image is first assigned to the most similar cluster according to its modality. In the update step, based on the current cluster hypothesis, the modality uniqueness and the sparse dictionary are updated. These two steps are formulated in an iterative manner. Based on the final clusters, a modalityinvariant marginalized kernel is then computed, where the similarities between the reconstructed features of each modality are aggregated across all clusters. Our framework enables the reliable inference of semantic-class category for an image, even across large photometric variations. Experimental results show that our method outperforms conventional methods on various benchmarks, such as landmark identification under severely varying weather conditions, domain-adapting image classification, and RGB and near-infrared (NIR) image classification.

  18. Imaging with hypertelescopes: a simple modal approach

    NASA Astrophysics Data System (ADS)

    Aime, C.

    2008-05-01

    Aims: We give a simple analysis of imaging with hypertelescopes, a technique proposed by Labeyrie to produce snapshot images using arrays of telescopes. The approach is modal: we describe the transformations induced by the densification onto a sinusoidal decomposition of the focal image instead of the usual point spread function approach. Methods: We first express the image formed at the focus of a diluted array of apertures as the product R_0(α) X_F(α) of the diffraction pattern of the elementary apertures R_0(α) by the object-dependent interference term X_F(α) between all apertures. The interference term, which can be written in the form of a Fourier Series for an extremely diluted array, produces replications of the object, which makes observing the image difficult. We express the focal image after the densification using the approach of Tallon and Tallon-Bosc. Results: The result is very simple for an extremely diluted array. We show that the focal image in a periscopic densification of the array can be written as R_0(α) X_F(α/γ), where γ is the factor of densification. There is a dilatation of the interference term while the diffraction term is unchanged. After de-zooming, the image can be written as γ2 X_F(α)R_0(γ α), an expression which clearly indicates that the final image corresponds to the center of the Fizeau image intensified by γ2. The imaging limitations of hypertelescopes are therefore those of the original configuration. The effect of the suppression of image replications is illustrated in a numerical simulation for a fully redundant configuration and a non-redundant one.

  19. Evaluation of registration strategies for multi-modality images of rat brain slices

    NASA Astrophysics Data System (ADS)

    Palm, Christoph; Vieten, Andrea; Salber, Dagmar; Pietrzyk, Uwe

    2009-05-01

    In neuroscience, small-animal studies frequently involve dealing with series of images from multiple modalities such as histology and autoradiography. The consistent and bias-free restacking of multi-modality image series is obligatory as a starting point for subsequent non-rigid registration procedures and for quantitative comparisons with positron emission tomography (PET) and other in vivo data. Up to now, consistency between 2D slices without cross validation using an inherent 3D modality is frequently presumed to be close to the true morphology due to the smooth appearance of the contours of anatomical structures. However, in multi-modality stacks consistency is difficult to assess. In this work, consistency is defined in terms of smoothness of neighboring slices within a single modality and between different modalities. Registration bias denotes the distortion of the registered stack in comparison to the true 3D morphology and shape. Based on these metrics, different restacking strategies of multi-modality rat brain slices are experimentally evaluated. Experiments based on MRI-simulated and real dual-tracer autoradiograms reveal a clear bias of the restacked volume despite quantitatively high consistency and qualitatively smooth brain structures. However, different registration strategies yield different inter-consistency metrics. If no genuine 3D modality is available, the use of the so-called SOP (slice-order preferred) or MOSOP (modality-and-slice-order preferred) strategy is recommended.

  20. Radiolabeling of Nanoparticles and Polymers for PET Imaging

    PubMed Central

    Stockhofe, Katharina; Postema, Johannes M.; Schieferstein, Hanno; Ross, Tobias L.

    2014-01-01

    Nanomedicine has become an emerging field in imaging and therapy of malignancies. Nanodimensional drug delivery systems have already been used in the clinic, as carriers for sensitive chemotherapeutics or highly toxic substances. In addition, those nanodimensional structures are further able to carry and deliver radionuclides. In the development process, non-invasive imaging by means of positron emission tomography (PET) represents an ideal tool for investigations of pharmacological profiles and to find the optimal nanodimensional architecture of the aimed-at drug delivery system. Furthermore, in a personalized therapy approach, molecular imaging modalities are essential for patient screening/selection and monitoring. Hence, labeling methods for potential drug delivery systems are an indispensable need to provide the radiolabeled analog. In this review, we describe and discuss various approaches and methods for the labeling of potential drug delivery systems using positron emitters. PMID:24699244

  1. Multi-modality molecular imaging for gastric cancer research

    NASA Astrophysics Data System (ADS)

    Liang, Jimin; Chen, Xueli; Liu, Junting; Hu, Hao; Qu, Xiaochao; Wang, Fu; Nie, Yongzhan

    2011-12-01

    Because of the ability of integrating the strengths of different modalities and providing fully integrated information, multi-modality molecular imaging techniques provide an excellent solution to detecting and diagnosing earlier cancer, which remains difficult to achieve by using the existing techniques. In this paper, we present an overview of our research efforts on the development of the optical imaging-centric multi-modality molecular imaging platform, including the development of the imaging system, reconstruction algorithms and preclinical biomedical applications. Primary biomedical results show that the developed optical imaging-centric multi-modality molecular imaging platform may provide great potential in the preclinical biomedical applications and future clinical translation.

  2. PET Imaging in Huntington’s Disease

    PubMed Central

    Roussakis, Andreas-Antonios; Piccini, Paola

    2015-01-01

    To date, little is known about how neurodegeneration and neuroinflammation propagate in Huntington’s disease (HD). Unfortunately, no treatment is available to cure or reverse the progressive decline of function caused by the disease, thus considering HD a fatal disease. Mutation gene carriers typically remain asymptomatic for many years although alterations in the basal ganglia and cortex occur early on in mutant HD gene–carriers. Positron Emission Tomography (PET) is a functional imaging technique of nuclear medicine which enables in vivo visualization of numerous biological molecules expressed in several human tissues. Brain PET is most powerful to study in vivo neuronal and glial cells function as well as cerebral blood flow in a plethora of neurodegenerative disorders including Parkinson’s disease, Alzheimer’s and HD. In absence of HD–specific biomarkers for monitoring disease progression, previous PET studies in HD were merely focused on the study of dopaminergic terminals, cerebral blood flow and glucose metabolism in manifest and premanifest HD–gene carriers. More recently, research interest has been exploring novel PET targets in HD including the state of phosphodiesterse expression and the role of activated microglia. Hence, a better understanding of the HD pathogenesis mechanisms may lead to the development of targeted therapies. PET imaging follow–up studies with novel selective PET radiotracers such as 11C-IMA–107 and 11C-PBR28 may provide insight on disease progression and identify prognostic biomarkers, elucidate the underlying HD pathology and assess novel pharmaceutical agents and over time. PMID:26683130

  3. Optimized PET imaging for 4D treatment planning in radiotherapy: the virtual 4D PET strategy.

    PubMed

    Gianoli, Chiara; Riboldi, Marco; Fontana, Giulia; Giri, Maria G; Grigolato, Daniela; Ferdeghini, Marco; Cavedon, Carlo; Baroni, Guido

    2015-02-01

    The purpose of the study is to evaluate the performance of a novel strategy, referred to as "virtual 4D PET", aiming at the optimization of hybrid 4D CT-PET scan for radiotherapy treatment planning. The virtual 4D PET strategy applies 4D CT motion modeling to avoid time-resolved PET image acquisition. This leads to a reduction of radioactive tracer administered to the patient and to a total acquisition time comparable to free-breathing PET studies. The proposed method exploits a motion model derived from 4D CT, which is applied to the free-breathing PET to recover respiratory motion and motion blur. The free-breathing PET is warped according to the motion model, in order to generate the virtual 4D PET. The virtual 4D PET strategy was tested on images obtained from a 4D computational anthropomorphic phantom. The performance was compared to conventional motion compensated 4D PET. Tests were also carried out on clinical 4D CT-PET scans coming from seven lung and liver cancer patients. The virtual 4D PET strategy was able to recover lesion motion, with comparable performance with respect to the motion compensated 4D PET. The compensation of the activity blurring due to motion was successfully achieved in terms of spill out removal. Specific limitations were highlighted in terms of partial volume compensation. Results on clinical 4D CT-PET scans confirmed the efficacy in 4D PET count statistics optimization, as equal to the free-breathing PET, and recovery of lesion motion. Compared to conventional motion compensation strategies that explicitly require 4D PET imaging, the virtual 4D PET strategy reduces clinical workload and computational costs, resulting in significant advantages for radiotherapy treatment planning.

  4. PET/CT imaging of abdominal aorta with intramural hematomas, penetrating ulcer, and saccular pseudoaneurysm.

    PubMed

    Nguyen, Vien X; Nguyen, Ba D

    2014-05-01

    Acute aortic syndromes, encompassing intramural hematoma, penetrating ulcer, and pseudoaneurysm, are best demonstrated by angiographic CT and magnetic resonance imaging. These imaging modalities provide an accurate evaluation and allow timely therapies of these frequently symptomatic lesions, thus reducing their morbidity and mortality. The inflammatory pathogenesis of these acute aortic syndromes may exhibit positive PET findings predictive of prognosis and outcomes of these vascular events. The authors present a case of PET/CT imaging showing asymptomatic intramural hematomas with penetrating ulcer and saccular pseudoaneurysm of the proximal abdominal aorta.

  5. Clinical Utility of Positron Emission Tomography Magnetic Resonance Imaging (PET-MRI) in Gastrointestinal Cancers

    PubMed Central

    Matthews, Robert; Choi, Minsig

    2016-01-01

    Anatomic imaging utilizing both CT (computed tomography) and MRI (magnetic resonance imaging) limits the assessment of cancer metastases in lymph nodes and distant organs while functional imaging like PET (positron emission tomography) scan has its limitation in spatial resolution capacity. Hybrid imaging utilizing PET-CT and PET-MRI are novel imaging modalities that are changing the current landscape in cancer diagnosis, staging, and treatment response. MRI has shown to have higher sensitivity in soft tissue, head and neck pathology, and pelvic disease, as well as, detecting small metastases in the liver and bone compared to CT. Combining MRI with PET allows for detection of metastases that may have been missed with current imaging modalities. In this review, we will examine the clinical utility of FDG PET-MRI in the diagnosis and staging of gastrointestinal cancers with focus on esophageal, stomach, colorectal, and pancreatic cancers. We will also explore its role in treatment response and future directions associated with it. PMID:27618106

  6. Current Status of Hybrid PET/MRI in Oncologic Imaging

    PubMed Central

    Rosenkrantz, Andrew B.; Friedman, Kent; Chandarana, Hersh; Melsaether, Amy; Moy, Linda; Ding, Yu-Shin; Jhaveri, Komal; Beltran, Luis; Jain, Rajan

    2016-01-01

    OBJECTIVE This review article explores recent advancements in PET/MRI for clinical oncologic imaging. CONCLUSION Radiologists should understand the technical considerations that have made PET/MRI feasible within clinical workflows, the role of PET tracers for imaging various molecular targets in oncology, and advantages of hybrid PET/MRI compared with PET/CT. To facilitate this understanding, we discuss clinical examples (including gliomas, breast cancer, bone metastases, prostate cancer, bladder cancer, gynecologic malignancy, and lymphoma) as well as future directions, challenges, and areas for continued technical optimization for PET/MRI. PMID:26491894

  7. Combined Modality Treatment for PET-Positive Non-Hodgkin Lymphoma: Favorable Outcomes of Combined Modality Treatment for Patients With Non-Hodgkin Lymphoma and Positive Interim or Postchemotherapy FDG-PET

    SciTech Connect

    Halasz, Lia M.; Jacene, Heather A.; Catalano, Paul J.; Van den Abbeele, Annick D.; LaCasce, Ann; Mauch, Peter M.; Ng, Andrea K.

    2012-08-01

    Purpose: To evaluate outcomes of patients treated for aggressive non-Hodgkin lymphoma (NHL) with combined modality therapy based on [{sup 18}F]fluoro-2-deoxy-2-D-glucose positron emission tomography (FDG-PET) response. Methods and Materials: We studied 59 patients with aggressive NHL, who received chemotherapy and radiation therapy (RT) from 2001 to 2008. Among them, 83% of patients had stage I/II disease. Patients with B-cell lymphoma received R-CHOP (rituximab, cyclophosphamide, doxorubicin, vincristine, and prednisone)-based chemotherapy, and 1 patient with anaplastic lymphoma kinase-negative anaplastic T-cell lymphoma received CHOP therapy. Interim and postchemotherapy FDG-PET or FDG-PET/computed tomography (CT) scans were performed for restaging. All patients received consolidated involved-field RT. Median RT dose was 36 Gy (range, 28.8-50 Gy). Progression-free survival (PFS) and local control (LC) rates were calculated with and without a negative interim or postchemotherapy FDG-PET scan. Results: Median follow-up was 46.5 months. Thirty-nine patients had negative FDG-PET results by the end of chemotherapy, including 12 patients who had a negative interim FDG-PET scan and no postchemotherapy PET. Twenty patients were FDG-PET-positive, including 7 patients with positive interim FDG-PET and no postchemotherapy FDG-PET scans. The 3-year actuarial PFS rates for patients with negative versus positive FDG-PET scans were 97% and 90%, respectively. The 3-year actuarial LC rates for patients with negative versus positive FDG-PET scans were 100% and 90%, respectively. Conclusions: Patients who had a positive interim or postchemotherapy FDG-PET had a PFS rate of 90% at 3 years after combined modality treatment, suggesting that a large proportion of these patients can be cured with consolidated RT.

  8. Joint Segmentation of Anatomical and Functional Images: Applications in Quantification of Lesions from PET, PET-CT, MRI-PET, and MRI-PET-CT Images

    PubMed Central

    Bagci, Ulas; Udupa, Jayaram K.; Mendhiratta, Neil; Foster, Brent; Xu, Ziyue; Yao, Jianhua; Chen, Xinjian; Mollura, Daniel J.

    2013-01-01

    We present a novel method for the joint segmentation of anatomical and functional images. Our proposed methodology unifies the domains of anatomical and functional images, represents them in a product lattice, and performs simultaneous delineation of regions based on random walk image segmentation. Furthermore, we also propose a simple yet effective object/background seed localization method to make the proposed segmentation process fully automatic. Our study uses PET, PET-CT, MRI-PET, and fused MRI-PET-CT scans (77 studies in all) from 56 patients who had various lesions in different body regions. We validated the effectiveness of the proposed method on different PET phantoms as well as on clinical images with respect to the ground truth segmentation provided by clinicians. Experimental results indicate that the presented method is superior to threshold and Bayesian methods commonly used in PET image segmentation, is more accurate and robust compared to the other PET-CT segmentation methods recently published in the literature, and also it is general in the sense of simultaneously segmenting multiple scans in real-time with high accuracy needed in routine clinical use. PMID:23837967

  9. [A non-local means approach for PET image denoising].

    PubMed

    Yin, Yong; Sun, Weifeng; Lu, Jie; Liu, Tonghai

    2010-04-01

    Denoising is an important issue for medical image processing. Based on the analysis of the Non-local means algorithm recently reported by Buades A, et al. in international journals we herein propose adapting it for PET image denoising. Experimental de-noising results for real clinical PET images show that Non-local means method is superior to median filtering and wiener filtering methods and it can suppress noise in PET images effectively and preserve important details of structure for diagnosis.

  10. Graph cut based co-segmentation of lung tumor in PET-CT images

    NASA Astrophysics Data System (ADS)

    Ju, Wei; Xiang, Dehui; Zhang, Bin; Chen, Xinjian

    2015-03-01

    Accurate segmentation of pulmonary tumor is important for clinicians to make appropriate diagnosis and treatment. Positron Emission Tomography (PET) and Computed Tomography (CT) are two commonly used imaging technologies for image-guided radiation therapy. In this study, we present a graph-based method to integrate the two modalities to segment the tumor simultaneously on PET and CT images. The co-segmentation problem is formulated as an energy minimization problem. Two weighted sub-graphs are constructed for PET and CT. The characteristic information of the two modalities is encoded on the edges of the graph. A context cost is enforced by adding context arcs to achieve consistent results between the two modalities. An optimal solution can be achieved by solving a maximum flow problem. The proposed segmentation method was validated on 18 sets of PET-CT images from different patients with non-small cell lung cancer (NSCLC). The quantitative results show significant improvement of our method with a mean DSC value 0.82.

  11. SPECT and PET Imaging of Meningiomas

    PubMed Central

    Valotassiou, Varvara; Leondi, Anastasia; Angelidis, George; Psimadas, Dimitrios; Georgoulias, Panagiotis

    2012-01-01

    Meningiomas arise from the meningothelial cells of the arachnoid membranes. They are the most common primary intracranial neoplasms and represent about 20% of all intracranial tumors. They are usually diagnosed after the third decade of life and they are more frequent in women than in men. According to the World Health Organization (WHO) criteria, meningiomas can be classified into grade I meningiomas, which are benign, grade II (atypical) and grade III (anaplastic) meningiomas, which have a much more aggressive clinical behaviour. Computed Tomography (CT) and Magnetic Resonance Imaging (MRI) are routinely used in the diagnostic workup of patients with meningiomas. Molecular Nuclear Medicine Imaging with Single Photon Emission Computed Tomography (SPECT) and Positron Emission Tomography (PET) could provide complementary information to CT and MRI. Various SPECT and PET tracers may provide information about cellular processes and biological characteristics of meningiomas. Therefore, SPECT and PET imaging could be used for the preoperative noninvasive diagnosis and differential diagnosis of meningiomas, prediction of tumor grade and tumor recurrence, response to treatment, target volume delineation for radiation therapy planning, and distinction between residual or recurrent tumour from scar tissue. PMID:22623896

  12. SPECT and PET imaging of meningiomas.

    PubMed

    Valotassiou, Varvara; Leondi, Anastasia; Angelidis, George; Psimadas, Dimitrios; Georgoulias, Panagiotis

    2012-01-01

    Meningiomas arise from the meningothelial cells of the arachnoid membranes. They are the most common primary intracranial neoplasms and represent about 20% of all intracranial tumors. They are usually diagnosed after the third decade of life and they are more frequent in women than in men. According to the World Health Organization (WHO) criteria, meningiomas can be classified into grade I meningiomas, which are benign, grade II (atypical) and grade III (anaplastic) meningiomas, which have a much more aggressive clinical behaviour. Computed Tomography (CT) and Magnetic Resonance Imaging (MRI) are routinely used in the diagnostic workup of patients with meningiomas. Molecular Nuclear Medicine Imaging with Single Photon Emission Computed Tomography (SPECT) and Positron Emission Tomography (PET) could provide complementary information to CT and MRI. Various SPECT and PET tracers may provide information about cellular processes and biological characteristics of meningiomas. Therefore, SPECT and PET imaging could be used for the preoperative noninvasive diagnosis and differential diagnosis of meningiomas, prediction of tumor grade and tumor recurrence, response to treatment, target volume delineation for radiation therapy planning, and distinction between residual or recurrent tumour from scar tissue.

  13. Positron emitting magnetic nanoconstructs for PET/MR imaging.

    PubMed

    Aryal, Santosh; Key, Jaehong; Stigliano, Cinzia; Landis, Melissa D; Lee, Daniel Y; Decuzzi, Paolo

    2014-07-09

    Hybrid PET/MRI scanners have the potential to provide fundamental molecular, cellular, and anatomic information essential for optimizing therapeutic and surgical interventions. However, their full utilization is currently limited by the lack of truly multi-modal contrast agents capable of exploiting the strengths of each modality. Here, we report on the development of long-circulating positron-emitting magnetic nanoconstructs (PEM) designed to image solid tumors for combined PET/MRI. PEMs are synthesized by a modified nano-precipitation method mixing poly(lactic-co-glycolic acid) (PLGA), lipids, and polyethylene glycol (PEG) chains with 5 nm iron oxide nanoparticles (USPIOs). PEM lipids are coupled with 1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetic acid (DOTA) and subsequently chelated to (64)Cu. PEMs show a diameter of 140 ± 7 nm and a transversal relaxivity r2 of 265.0 ± 10.0 (mM × s)(-1), with a r2/r1 ratio of 123. Using a murine xenograft model bearing human breast cancer cell line (MDA-MB-231), intravenously administered PEMs progressively accumulate in tumors reaching a maximum of 3.5 ± 0.25% ID/g tumor at 20 h post-injection. Correlation of PET and MRI signals revealed non-uniform intratumoral distribution of PEMs with focal areas of accumulation at the tumor periphery. These long-circulating PEMs with high transversal relaxivity and tumor accumulation may allow for detailed interrogation over multiple scales in a clinically relevant setting.

  14. Comparative effectiveness of imaging modalities to determine metastatic breast cancer treatment response.

    PubMed

    Lee, Christoph I; Gold, Laura S; Nelson, Heidi D; Chou, Roger; Ramsey, Scott D; Sullivan, Sean D

    2015-02-01

    We performed a systematic review to address the comparative effectiveness of different imaging modalities in evaluating treatment response among metastatic breast cancer patients. We searched seven multidisciplinary electronic databases for relevant publications (January 2003-December 2013) and performed dual abstraction of details and results for all clinical studies that involved stage IV breast cancer patients and evaluated imaging for detecting treatment response. Among 159 citations reviewed, 17 single-institution, non-randomized, observational studies met our inclusion criteria. Several studies demonstrate that changes in PET/CT standard uptake values are associated with changes in tumor volume as determined by bone scan, MRI, and/or CT. However, no studies evaluated comparative test performance between modalities or determined relationships between imaging findings and subsequent clinical decisions. Evidence for imaging's effectiveness in determining treatment response among metastatic breast cancer patients is limited. More rigorous research is needed to address imaging's value in this patient population.

  15. The Role of 18F-FDG PET/CT Integrated Imaging in Distinguishing Malignant from Benign Pleural Effusion

    PubMed Central

    Sun, Yajuan; Yu, Hongjuan; Ma, Jingquan

    2016-01-01

    18F-FDG PET/CT integrated imaging compared with 18F-FDG PET imaging (Kappa = 0.881 and Kappa = 0.240, respectively). Conclusion 18F-FDG PET/CT integrated imaging is a more reliable modality in distinguishing malignant from benign pleural effusion than 18F-FDG PET imaging and CT imaging alone. For image interpretation of 18F-FDG PET/CT integrated imaging, the PET and CT portions play a major diagnostic role in identifying metastatic effusion and benign effusion, respectively. PMID:27560933

  16. 18F-fluorothymidine-pet imaging of glioblastoma multiforme: effects of radiation therapy on radiotracer uptake and molecular biomarker patterns.

    PubMed

    Chandrasekaran, Sanjay; Hollander, Andrew; Xu, Xiangsheng; Benci, Joseph L; Davis, James J; Dorsey, Jay F; Kao, Gary

    2013-01-01

    Introduction. PET imaging is a useful clinical tool for studying tumor progression and treatment effects. Conventional (18)F-FDG-PET imaging is of limited usefulness for imaging Glioblastoma Multiforme (GBM) due to high levels of glucose uptake by normal brain and the resultant signal-to-noise intensity. (18)F-Fluorothymidine (FLT) in contrast has shown promise for imaging GBM, as thymidine is taken up preferentially by proliferating cells. These studies were undertaken to investigate the effectiveness of (18)F-FLT-PET in a GBM mouse model, especially after radiation therapy (RT), and its correlation with useful biomarkers, including proliferation and DNA damage. Methods. Nude/athymic mice with human GBM orthografts were assessed by microPET imaging with (18)F-FDG and (18)F-FLT. Patterns of tumor PET imaging were then compared to immunohistochemistry and immunofluorescence for markers of proliferation (Ki-67), DNA damage and repair (γH2AX), hypoxia (HIF-1α), and angiogenesis (VEGF). Results. We confirmed that (18)F-FLT-PET uptake is limited in healthy mice but enhanced in the intracranial tumors. Our data further demonstrate that (18)F-FLT-PET imaging usefully reflects the inhibition of tumor by RT and correlates with changes in biomarker expression. Conclusions. (18)F-FLT-PET imaging is a promising tumor imaging modality for GBM, including assessing RT effects and biologically relevant biomarkers.

  17. Impact of motion and partial volume effects correction on PET myocardial perfusion imaging using simultaneous PET-MR

    PubMed Central

    Petibon, Yoann; Guehl, Nicolas J.; Reese, Timothy G.; Ebrahimi, Behzad; Normandin, Marc D.; Shoup, Timothy M.; Alpert, Nathaniel M.; El Fakhri, Georges; Ouyang, Jinsong

    2017-01-01

    PET is an established modality for myocardial perfusion imaging (MPI) which enables quantification of absolute myocardial blood flow (MBF) using dynamic imaging and kinetic modeling. However, heart motion and Partial Volume Effects (PVE) significantly limit the spatial resolution and quantitative accuracy of PET MPI. Simultaneous PET-MR offers a solution to the motion problem in PET by enabling MR-based motion correction of PET data. The aim of this study was to develop a motion and PVE correction methodology for PET MPI using simultaneous PET-MR, and to assess its impact on both static and dynamic PET MPI using 18F-Flurpiridaz, a novel 18F-labeled perfusion tracer. Two dynamic 18F-Flurpiridaz MPI scans were performed on healthy pigs using a PET-MR scanner. Cardiac motion was tracked using a dedicated tagged-MRI (tMR) sequence. Motion fields were estimated using non-rigid registration of tMR images and used to calculate motion-dependent attenuation maps. Motion correction of PET data was achieved by incorporating tMR-based motion fields and motion-dependent attenuation coefficients into image reconstruction. Dynamic and static PET datasets were created for each scan. Each dataset was reconstructed as (i) Ungated, (ii) Gated (end-diastolic phase), and (iii) Motion-Corrected (MoCo), each without and with point spread function (PSF) modeling for PVE correction. Myocardium-to-blood concentration ratios (MBR) and apparent wall thickness were calculated to assess image quality for static MPI. For dynamic MPI, segment- and voxel-wise myocardial blood flow (MBF) values were estimated by non-linear fitting of a 2-tissue compartment model to tissue time-activity-curves. MoCo and Gating respectively decreased mean apparent wall thickness by 15.1% and 14.4% and increased MBR by 20.3% and 13.6% compared to Ungated images (P<0.01). Combined motion and PSF correction (MoCo-PSF) yielded 30.9% (15.7%) lower wall thickness and 82.2% (20.5%) higher MBR compared to Ungated data

  18. Impact of motion and partial volume effects correction on PET myocardial perfusion imaging using simultaneous PET-MR

    NASA Astrophysics Data System (ADS)

    Petibon, Yoann; Guehl, Nicolas J.; Reese, Timothy G.; Ebrahimi, Behzad; Normandin, Marc D.; Shoup, Timothy M.; Alpert, Nathaniel M.; El Fakhri, Georges; Ouyang, Jinsong

    2017-01-01

    PET is an established modality for myocardial perfusion imaging (MPI) which enables quantification of absolute myocardial blood flow (MBF) using dynamic imaging and kinetic modeling. However, heart motion and partial volume effects (PVE) significantly limit the spatial resolution and quantitative accuracy of PET MPI. Simultaneous PET-MR offers a solution to the motion problem in PET by enabling MR-based motion correction of PET data. The aim of this study was to develop a motion and PVE correction methodology for PET MPI using simultaneous PET-MR, and to assess its impact on both static and dynamic PET MPI using 18F-Flurpiridaz, a novel 18F-labeled perfusion tracer. Two dynamic 18F-Flurpiridaz MPI scans were performed on healthy pigs using a PET-MR scanner. Cardiac motion was tracked using a dedicated tagged-MRI (tMR) sequence. Motion fields were estimated using non-rigid registration of tMR images and used to calculate motion-dependent attenuation maps. Motion correction of PET data was achieved by incorporating tMR-based motion fields and motion-dependent attenuation coefficients into image reconstruction. Dynamic and static PET datasets were created for each scan. Each dataset was reconstructed as (i) Ungated, (ii) Gated (end-diastolic phase), and (iii) Motion-Corrected (MoCo), each without and with point spread function (PSF) modeling for PVE correction. Myocardium-to-blood concentration ratios (MBR) and apparent wall thickness were calculated to assess image quality for static MPI. For dynamic MPI, segment- and voxel-wise MBF values were estimated by non-linear fitting of a 2-tissue compartment model to tissue time-activity-curves. MoCo and Gating respectively decreased mean apparent wall thickness by 15.1% and 14.4% and increased MBR by 20.3% and 13.6% compared to Ungated images (P  <  0.01). Combined motion and PSF correction (MoCo-PSF) yielded 30.9% (15.7%) lower wall thickness and 82.2% (20.5%) higher MBR compared to Ungated data reconstructed

  19. Impact of medical therapy on atheroma volume measured by different cardiovascular imaging modalities.

    PubMed

    Sinno, Mohamad C N; Al-Mallah, Mouaz

    2010-01-01

    Atherosclerosis is a systemic disease that affects most vascular beds. The gold standard of atherosclerosis imaging has been invasive intravascular ultrasound (IVUS). Newer noninvasive imaging modalities like B-mode ultrasound, cardiac computed tomography (CT), positron emission tomography (PET), and magnetic resonance imaging (MRI) have been used to assess these vascular territories with high accuracy and reproducibility. These imaging modalities have lately been used for the assessment of the atherosclerotic plaque and the response of its volume to several medical therapies used in the treatment of patients with cardiovascular disease. To study the impact of these medications on atheroma volume progression or regression, imaging modalities have been used on a serial basis providing a unique opportunity to monitor the effect these antiatherosclerotic strategies exert on plaque burden. As a result, studies incorporating serial IVUS imaging, quantitative coronary angiography (QCA), B-mode ultrasound, electron beam computed tomography (EBCT), and dynamic contrast-enhanced magnetic resonance imaging have all been used to evaluate the impact of therapeutic strategies that modify cholesterol and blood pressure on the progression/regression of atherosclerotic plaque. In this review, we intend to summarize the impact of different therapies aimed at halting the progression or even result in regression of atherosclerotic cardiovascular disease evaluated by different imaging modalities.

  20. Positron emission tomography (PET) imaging with 18F-based radiotracers

    PubMed Central

    Alauddin, Mian M

    2012-01-01

    Positron Emission Tomography (PET) is a nuclear medicine imaging technique that is widely used in early detection and treatment follow up of many diseases, including cancer. This modality requires positron-emitting isotope labeled biomolecules, which are synthesized prior to perform imaging studies. Fluorine-18 is one of the several isotopes of fluorine that is routinely used in radiolabeling of biomolecules for PET; because of its positron emitting property and favorable half-life of 109.8 min. The biologically active molecule most commonly used for PET is 2-deoxy-2-18F-fluoro-β-D-glucose (18F-FDG), an analogue of glucose, for early detection of tumors. The concentrations of tracer accumulation (PET image) demonstrate the metabolic activity of tissues in terms of regional glucose metabolism and accumulation. Other tracers are also used in PET to image the tissue concentration. In this review, information on fluorination and radiofluorination reactions, radiofluorinating agents, and radiolabeling of various compounds and their application in PET imaging is presented. PMID:23133802

  1. The application of PET imaging in psychoneuroimmunology research.

    PubMed

    Hannestad, Jonas

    2012-01-01

    Positron emission tomography (PET) imaging is a research tool that allows in vivo measurements of brain metabolism and specific target molecules. PET imaging can be used to measure these brain variables in a variety of species, including human and non-human primates, and rodents. PET imaging can therefore be combined with various experimental and clinical model systems that are commonly used in psychoneuroimmunology research.

  2. PET/SPECT molecular imaging in clinical neuroscience: recent advances in the investigation of CNS diseases

    PubMed Central

    Lu, Feng-Mei

    2015-01-01

    Molecular imaging is an attractive technology widely used in clinical practice that greatly enhances our understanding of the pathophysiology and treatment in central nervous system (CNS) diseases. It is a novel multidisciplinary technique that can be defined as real-time visualization, in vivo characterization and qualification of biological processes at the molecular and cellular level. It involves the imaging modalities and the corresponding imaging agents. Nowadays, molecular imaging in neuroscience has provided tremendous insights into disturbed human brain function. Among all of the molecular imaging modalities, positron emission tomography (PET) and single photon emission computed tomography (SPECT) have occupied a particular position that visualize and measure the physiological processes using high-affinity and high-specificity molecular radioactive tracers as imaging probes in intact living brain. In this review, we will put emphasis on the PET/SPECT applications in Alzheimer’s disease (AD) and Parkinson’s disease (PD) as major CNS disorders. We will first give an overview of the main classical molecular neuroimaging modalities. Then, the major clinical applications of PET and SPECT along with molecular probes in the fields of psychiatry and neurology will be discussed. PMID:26029646

  3. Intraoperative Imaging-Guided Cancer Surgery: From Current Fluorescence Molecular Imaging Methods to Future Multi-Modality Imaging Technology

    PubMed Central

    Chi, Chongwei; Du, Yang; Ye, Jinzuo; Kou, Deqiang; Qiu, Jingdan; Wang, Jiandong; Tian, Jie; Chen, Xiaoyuan

    2014-01-01

    Cancer is a major threat to human health. Diagnosis and treatment using precision medicine is expected to be an effective method for preventing the initiation and progression of cancer. Although anatomical and functional imaging techniques such as radiography, computed tomography (CT), magnetic resonance imaging (MRI) and positron emission tomography (PET) have played an important role for accurate preoperative diagnostics, for the most part these techniques cannot be applied intraoperatively. Optical molecular imaging is a promising technique that provides a high degree of sensitivity and specificity in tumor margin detection. Furthermore, existing clinical applications have proven that optical molecular imaging is a powerful intraoperative tool for guiding surgeons performing precision procedures, thus enabling radical resection and improved survival rates. However, detection depth limitation exists in optical molecular imaging methods and further breakthroughs from optical to multi-modality intraoperative imaging methods are needed to develop more extensive and comprehensive intraoperative applications. Here, we review the current intraoperative optical molecular imaging technologies, focusing on contrast agents and surgical navigation systems, and then discuss the future prospects of multi-modality imaging technology for intraoperative imaging-guided cancer surgery. PMID:25250092

  4. Dedicated PET scanners for breast imaging.

    PubMed

    Freifelder, R; Karp, J S

    1997-12-01

    We have used computer simulations to compare two designs for a PET scanner dedicated to breast imaging with a whole-body PET scanner. The new designs combine high spatial resolution, high sensitivity, and good energy resolution to detect small, low-contrast masses. The detectors are position sensitive NaI(Tl) scintillators. The first design is a ring scanner surrounding the breast and the second consists of two planar detectors placed on opposite sides of the breast. We have employed standard performance measures to compare the different designs: contrast, percentage standard deviation of the background, and signal-to-noise ratios of reconstructed images. The results of the simulations show that both of the proposed designs have better lesion detectability than a whole-body scanner. The results also show that contrast is higher in the ring breast system but that the noise is lower in the planar breast system. Overall, the ring system yields images with the best signal-to-noise ratios, although the planar system offers practical advantages for imaging the breast and axilla.

  5. Dedicated PET scanners for breast imaging

    NASA Astrophysics Data System (ADS)

    Freifelder, Richard; Karp, Joel S.

    1997-12-01

    We have used computer simulations to compare two designs for a PET scanner dedicated to breast imaging with a whole-body PET scanner. The new designs combine high spatial resolution, high sensitivity, and good energy resolution to detect small, low-contrast masses. The detectors are position sensitive NaI(Tl) scintillators. The first design is a ring scanner surrounding the breast and the second consists of two planar detectors placed on opposite sides of the breast. We have employed standard performance measures to compare the different designs: contrast, percentage standard deviation of the background, and signal-to-noise ratios of reconstructed images. The results of the simulations show that both of the proposed designs have better lesion detectability than a whole-body scanner. The results also show that contrast is higher in the ring breast system but that the noise is lower in the planar breast system. Overall, the ring system yields images with the best signal-to-noise ratios, although the planar system offers practical advantages for imaging the breast and axilla.

  6. MR-guided PET motion correction in LOR space using generic projection data for image reconstruction with PRESTO

    NASA Astrophysics Data System (ADS)

    Scheins, J.; Ullisch, M.; Tellmann, L.; Weirich, C.; Rota Kops, E.; Herzog, H.; Shah, N. J.

    2013-02-01

    The BrainPET scanner from Siemens, designed as hybrid MR/PET system for simultaneous acquisition of both modalities, provides high-resolution PET images with an optimum resolution of 3 mm. However, significant head motion often compromises the achievable image quality, e.g. in neuroreceptor studies of human brain. This limitation can be omitted when tracking the head motion and accurately correcting measured Lines-of-Response (LORs). For this purpose, we present a novel method, which advantageously combines MR-guided motion tracking with the capabilities of the reconstruction software PRESTO (PET Reconstruction Software Toolkit) to convert motion-corrected LORs into highly accurate generic projection data. In this way, the high-resolution PET images achievable with PRESTO can also be obtained in presence of severe head motion.

  7. Automatic anatomy recognition in whole-body PET/CT images

    SciTech Connect

    Wang, Huiqian; Udupa, Jayaram K. Odhner, Dewey; Tong, Yubing; Torigian, Drew A.; Zhao, Liming

    2016-01-15

    Purpose: Whole-body positron emission tomography/computed tomography (PET/CT) has become a standard method of imaging patients with various disease conditions, especially cancer. Body-wide accurate quantification of disease burden in PET/CT images is important for characterizing lesions, staging disease, prognosticating patient outcome, planning treatment, and evaluating disease response to therapeutic interventions. However, body-wide anatomy recognition in PET/CT is a critical first step for accurately and automatically quantifying disease body-wide, body-region-wise, and organwise. This latter process, however, has remained a challenge due to the lower quality of the anatomic information portrayed in the CT component of this imaging modality and the paucity of anatomic details in the PET component. In this paper, the authors demonstrate the adaptation of a recently developed automatic anatomy recognition (AAR) methodology [Udupa et al., “Body-wide hierarchical fuzzy modeling, recognition, and delineation of anatomy in medical images,” Med. Image Anal. 18, 752–771 (2014)] to PET/CT images. Their goal was to test what level of object localization accuracy can be achieved on PET/CT compared to that achieved on diagnostic CT images. Methods: The authors advance the AAR approach in this work in three fronts: (i) from body-region-wise treatment in the work of Udupa et al. to whole body; (ii) from the use of image intensity in optimal object recognition in the work of Udupa et al. to intensity plus object-specific texture properties, and (iii) from the intramodality model-building-recognition strategy to the intermodality approach. The whole-body approach allows consideration of relationships among objects in different body regions, which was previously not possible. Consideration of object texture allows generalizing the previous optimal threshold-based fuzzy model recognition method from intensity images to any derived fuzzy membership image, and in the process

  8. Molecular Platform for Design and Synthesis of Targeted Dual-Modality Imaging Probes

    PubMed Central

    2015-01-01

    We report a versatile dendritic structure based platform for construction of targeted dual-modality imaging probes. The platform contains multiple copies of 1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetic acid (DOTA) branching out from a 1,4,7-triazacyclononane-N,N′,N″-triacetic acid (NOTA) core. The specific coordination chemistries of the NOTA and DOTA moieties offer specific loading of 68/67Ga3+ and Gd3+, respectively, into a common molecular scaffold. The platform also contains three amino groups which can potentiate targeted dual-modality imaging of PET/MRI or SPECT/MRI (PET: positron emission tomography; SPECT: single photon emission computed tomography; MRI: magnetic resonance imaging) when further functionalized by targeting vectors of interest. To validate this design concept, a bimetallic complex was synthesized with six peripheral Gd-DOTA units and one Ga-NOTA core at the center, whose ion T1 relaxivity per gadolinium atom was measured to be 15.99 mM–1 s–1 at 20 MHz. Further, the bimetallic agent demonstrated its anticipated in vivo stability, tissue distribution, and pharmacokinetic profile when labeled with 67Ga. When conjugated with a model targeting peptide sequence, the trivalent construct was able to visualize tumors in a mouse xenograft model by both PET and MRI via a single dose injection. PMID:25615011

  9. Multiscale Texture Analysis: From 18F-FDG PET Images to Histologic Images.

    PubMed

    Orlhac, Fanny; Thézé, Benoit; Soussan, Michaël; Boisgard, Raphaël; Buvat, Irène

    2016-11-01

    Characterizing tumor heterogeneity using texture indices derived from PET images has shown promise in predicting treatment response and patient survival in some types of cancer. Yet, the relationship between PET-derived texture indices, precise tracer distribution, and biologic heterogeneity needs to be clarified. We investigated this relationship using PET images, autoradiographic images, and histologic images.

  10. SiPM-PET with a short optical fiber bundle for simultaneous PET-MR imaging.

    PubMed

    Hong, Seong Jong; Kang, Han Gyoo; Ko, Guen Bae; Song, In Chan; Rhee, June-Tak; Lee, Jae Sung

    2012-06-21

    For positron emission tomography (PET) inserts to magnetic resonance imaging (MRI) applications, optical fibers have been used for some time to transfer scintillation photons to photomultiplier tubes positioned outside the fringe magnetic field. We previously proposed a novel utilization of an optical fiber for good radio frequency (RF) transmission from body coils to an imaging object. Optical fiber bundles between silicon photomultipliers (SiPM) and scintillation crystals provide an increased spacing between RF-shielded electronics boxes, facilitating RF passage from the body RF coils to imaging objects. In this paper, we present test results of a SiPM-PET system with a short optical fiber bundle for simultaneous PET-MR imaging. We built the SiPM-PET system which consisted of 12 SiPM-PET modules; each module was assembled with a lutetium yttrium oxyorthosilicatecrystal block, a 31 mm optical fiber bundle, a Hamamatsu multi-pixel photon counter S11064-050P and a signal processing box shielded with copper. The SiPM-PET system, with a face-to-face distance of 71 mm, was placed inside a 3 T MRI. A small surface coil placed inside the SiPM-PET system was used to receive the signal from phantoms while the body RF coil transmitted the RF pulses. The SiPM-PET system showed little performance degradation during the simultaneous PET-MR imaging and it caused no significant degradation of MR images with turbo spin echo (TSE), gradient echo or 3D spoiled gradient recalled sequences. Echo planar imaging MR images with and without the SiPM-PET inside the MR scanner were significantly worse than the images obtained with the TSE sequence.

  11. (68)Ga-PSMA PET/CT: Joint EANM and SNMMI procedure guideline for prostate cancer imaging: version 1.0.

    PubMed

    Fendler, Wolfgang P; Eiber, Matthias; Beheshti, Mohsen; Bomanji, Jamshed; Ceci, Francesco; Cho, Steven; Giesel, Frederik; Haberkorn, Uwe; Hope, Thomas A; Kopka, Klaus; Krause, Bernd J; Mottaghy, Felix M; Schöder, Heiko; Sunderland, John; Wan, Simon; Wester, Hans-Jürgen; Fanti, Stefano; Herrmann, Ken

    2017-03-10

    The aim of this guideline is to provide standards for the recommendation, performance, interpretation and reporting of (68)Ga-PSMA PET/CT for prostate cancer imaging. These recommendations will help to improve accuracy, precision, and repeatability of (68)Ga-PSMA PET/CT for prostate cancer essentially needed for implementation of this modality in science and routine clinical practice.

  12. Advanced Tracers in PET Imaging of Cardiovascular Disease

    PubMed Central

    Zhang, Wei; Wu, Hua; Liu, Gang

    2014-01-01

    Cardiovascular disease is the leading cause of death worldwide. Molecular imaging with targeted tracers by positron emission tomography (PET) allows for the noninvasive detection and characterization of biological changes at the molecular level, leading to earlier disease detection, objective monitoring of therapies, and better prognostication of cardiovascular diseases progression. Here we review, the current role of PET in cardiovascular disease, with emphasize on tracers developed for PET imaging of cardiovascular diseases. PMID:25389529

  13. A graph-based approach for the retrieval of multi-modality medical images.

    PubMed

    Kumar, Ashnil; Kim, Jinman; Wen, Lingfeng; Fulham, Michael; Feng, Dagan

    2014-02-01

    In this paper, we address the retrieval of multi-modality medical volumes, which consist of two different imaging modalities, acquired sequentially, from the same scanner. One such example, positron emission tomography and computed tomography (PET-CT), provides physicians with complementary functional and anatomical features as well as spatial relationships and has led to improved cancer diagnosis, localisation, and staging. The challenge of multi-modality volume retrieval for cancer patients lies in representing the complementary geometric and topologic attributes between tumours and organs. These attributes and relationships, which are used for tumour staging and classification, can be formulated as a graph. It has been demonstrated that graph-based methods have high accuracy for retrieval by spatial similarity. However, naïvely representing all relationships on a complete graph obscures the structure of the tumour-anatomy relationships. We propose a new graph structure derived from complete graphs that structurally constrains the edges connected to tumour vertices based upon the spatial proximity of tumours and organs. This enables retrieval on the basis of tumour localisation. We also present a similarity matching algorithm that accounts for different feature sets for graph elements from different imaging modalities. Our method emphasises the relationships between a tumour and related organs, while still modelling patient-specific anatomical variations. Constraining tumours to related anatomical structures improves the discrimination potential of graphs, making it easier to retrieve similar images based on tumour location. We evaluated our retrieval methodology on a dataset of clinical PET-CT volumes. Our results showed that our method enabled the retrieval of multi-modality images using spatial features. Our graph-based retrieval algorithm achieved a higher precision than several other retrieval techniques: gray-level histograms as well as state

  14. Automated image registration for FDOPA PET studies

    NASA Astrophysics Data System (ADS)

    Lin, Kang-Ping; Huang, Sung-Cheng; Yu, Dan-Chu; Melega, William; Barrio, Jorge R.; Phelps, Michael E.

    1996-12-01

    In this study, various image registration methods are investigated for their suitability for registration of L-6-[18F]-fluoro-DOPA (FDOPA) PET images. Five different optimization criteria including sum of absolute difference (SAD), mean square difference (MSD), cross-correlation coefficient (CC), standard deviation of pixel ratio (SDPR), and stochastic sign change (SSC) were implemented and Powell's algorithm was used to optimize the criteria. The optimization criteria were calculated either unidirectionally (i.e. only evaluating the criteria for comparing the resliced image 1 with the original image 2) or bidirectionally (i.e. averaging the criteria for comparing the resliced image 1 with the original image 2 and those for the sliced image 2 with the original image 1). Monkey FDOPA images taken at various known orientations were used to evaluate the accuracy of different methods. A set of human FDOPA dynamic images was used to investigate the ability of the methods for correcting subject movement. It was found that a large improvement in performance resulted when bidirectional rather than unidirectional criteria were used. Overall, the SAD, MSD and SDPR methods were found to be comparable in performance and were suitable for registering FDOPA images. The MSD method gave more adequate results for frame-to-frame image registration for correcting subject movement during a dynamic FDOPA study. The utility of the registration method is further demonstrated by registering FDOPA images in monkeys before and after amphetamine injection to reveal more clearly the changes in spatial distribution of FDOPA due to the drug intervention.

  15. Review: comparison of PET rubidium-82 with conventional SPECT myocardial perfusion imaging.

    PubMed

    Ghotbi, Adam A; Kjaer, Andreas; Hasbak, Philip

    2014-05-01

    Nuclear cardiology has for many years been focused on gamma camera technology. With ever improving cameras and software applications, this modality has developed into an important assessment tool for ischaemic heart disease. However, the development of new perfusion tracers has been scarce. While cardiac positron emission tomography (PET) so far largely has been limited to centres with on-site cyclotron, recent developments with generator produced perfusion tracers such as rubidium-82, as well as an increasing number of PET scanners installed, may enable a larger patient flow that may supersede that of gamma camera myocardial perfusion imaging.

  16. PET imaging of adoptive progenitor cell therapies.

    SciTech Connect

    Gelovani, Juri G.

    2008-05-13

    Objectives. The overall objective of this application is to develop novel technologies for non-invasive imaging of adoptive stem cell-based therapies with positron emission tomography (PET) that would be applicable to human patients. To achieve this objective, stem cells will be genetically labeled with a PET-reporter gene and repetitively imaged to assess their distribution, migration, differentiation, and persistence using a radiolabeled reporter probe. This new imaging technology will be tested in adoptive progenitor cell-based therapy models in animals, including: delivery pro-apoptotic genes to tumors, and T-cell reconstitution for immunostimulatory therapy during allogeneic bone marrow progenitor cell transplantation. Technical and Scientific Merits. Non-invasive whole body imaging would significantly aid in the development and clinical implementation of various adoptive progenitor cell-based therapies by providing the means for non-invasive monitoring of the fate of injected progenitor cells over a long period of observation. The proposed imaging approaches could help to address several questions related to stem cell migration and homing, their long-term viability, and their subsequent differentiation. The ability to image these processes non-invasively in 3D and repetitively over a long period of time is very important and will help the development and clinical application of various strategies to control and direct stem cell migration and differentiation. Approach to accomplish the work. Stem cells will be genetically with a reporter gene which will allow for repetitive non-invasive “tracking” of the migration and localization of genetically labeled stem cells and their progeny. This is a radically new approach that is being developed for future human applications and should allow for a long term (many years) repetitive imaging of the fate of tissues that develop from the transplanted stem cells. Why the approach is appropriate. The novel approach to

  17. Random Walk and Graph Cut for Co-Segmentation of Lung Tumor on PET-CT Images.

    PubMed

    Ju, Wei; Xiang, Dehui; Xiang, Deihui; Zhang, Bin; Wang, Lirong; Kopriva, Ivica; Chen, Xinjian

    2015-12-01

    Accurate lung tumor delineation plays an important role in radiotherapy treatment planning. Since the lung tumor has poor boundary in positron emission tomography (PET) images and low contrast in computed tomography (CT) images, segmentation of tumor in the PET and CT images is a challenging task. In this paper, we effectively integrate the two modalities by making fully use of the superior contrast of PET images and superior spatial resolution of CT images. Random walk and graph cut method is integrated to solve the segmentation problem, in which random walk is utilized as an initialization tool to provide object seeds for graph cut segmentation on the PET and CT images. The co-segmentation problem is formulated as an energy minimization problem which is solved by max-flow/min-cut method. A graph, including two sub-graphs and a special link, is constructed, in which one sub-graph is for the PET and another is for CT, and the special link encodes a context term which penalizes the difference of the tumor segmentation on the two modalities. To fully utilize the characteristics of PET and CT images, a novel energy representation is devised. For the PET, a downhill cost and a 3D derivative cost are proposed. For the CT, a shape penalty cost is integrated into the energy function which helps to constrain the tumor region during the segmentation. We validate our algorithm on a data set which consists of 18 PET-CT images. The experimental results indicate that the proposed method is superior to the graph cut method solely using the PET or CT is more accurate compared with the random walk method, random walk co-segmentation method, and non-improved graph cut method.

  18. Design of an Image Fusion Phantom for a Small Animal microPET/CT Scanner Prototype

    NASA Astrophysics Data System (ADS)

    Nava-García, Dante; Alva-Sánchez, Héctor; Murrieta-Rodríguez, Tirso; Martínez-Dávalos, Arnulfo; Rodríguez-Villafuerte, Mercedes

    2010-12-01

    Two separate microtomography systems recently developed at Instituto de Física, UNAM, produce anatomical (microCT) and physiological images (microPET) of small animals. In this work, the development and initial tests of an image fusion method based on fiducial markers for image registration between the two modalities are presented. A modular Helix/Line-Sources phantom was designed and constructed; this phantom contains fiducial markers that can be visualized in both imaging systems. The registration was carried out by solving the rigid body alignment problem of Procrustes to obtain rotation and translation matrices required to align the two sets of images. The microCT/microPET image fusion of the Helix/Line-Sources phantom shows excellent visual coincidence between different structures, showing a calculated target-registration-error of 0.32 mm.

  19. SU-E-J-222: Evaluation of Deformable Registration of PET/CT Images for Cervical Cancer Brachytherapy

    SciTech Connect

    Liao, Y; Turian, J; Templeton, A; Kiel, K; Chu, J; Kadir, T

    2014-06-01

    Purpose: PET/CT provides important functional information for radiotherapy targeting of cervical cancer. However, repeated PET/CT procedures for external beam and subsequent brachytherapy expose patients to additional radiation and are not cost effective. Our goal is to investigate the possibility of propagating PET-active volumes for brachytherapy procedures through deformable image registration (DIR) of earlier PET/CT and ultimately to minimize the number of PET/CT image sessions required. Methods: Nine cervical cancer patients each received their brachytherapy preplanning PET/CT at the end of EBRT with a Syed template in place. The planning PET/CT was acquired on the day of brachytherapy treatment with the actual applicator (Syed or Tandem and Ring) and rigidly registered. The PET/CT images were then deformably registered creating a third (deformed) image set for target prediction. Regions of interest with standardized uptake values (SUV) greater than 65% of maximum SUV were contoured as target volumes in all three sets of PET images. The predictive value of the registered images was evaluated by comparing the preplanning and deformed PET volumes with the planning PET volume using Dice's coefficient (DC) and center-of-mass (COM) displacement. Results: The average DCs were 0.12±0.14 and 0.19±0.16 for rigid and deformable predicted target volumes, respectively. The average COM displacements were 1.9±0.9 cm and 1.7±0.7 cm for rigid and deformable registration, respectively. The DCs were improved by deformable registration, however, both were lower than published data for DIR in other modalities and clinical sites. Anatomical changes caused by different brachytherapy applicators could have posed a challenge to the DIR algorithm. The physiological change from interstitial needle placement may also contribute to lower DC. Conclusion: The clinical use of DIR in PET/CT for cervical cancer brachytherapy appears to be limited by applicator choice and requires further

  20. Imaging corn plants with PhytoPET, a modular PET system for plant biology

    SciTech Connect

    Lee, S.; Kross, B.; McKisson, J.; McKisson, J. E.; Weisenberger, A. G.; Xi, W.; Zorn, C.; Bonito, G.; Howell, C. R.; Reid, C. D.; Crowell, A.; Cumberbatch, L. C.; Topp, C.; Smith, M. F.

    2013-11-01

    PhytoPET is a modular positron emission tomography (PET) system designed specifically for plant imaging. The PhytoPET design allows flexible arrangements of PET detectors based on individual standalone detector modules built from single Hamamatsu H8500 position sensitive photomultiplier tubes and pixelated LYSO arrays. We have used the PhytoPET system to perform preliminary corn plant imaging studies at the Duke University Biology Department Phytotron. Initial evaluation of the PhytoPET system to image the biodistribution of the positron emitting tracer {sup 11}C in corn plants is presented. {sup 11}CO{sub 2} is loaded into corn seedlings by a leaf-labeling cuvette and translocation of {sup 11}C-sugars is imaged by a flexible arrangement of PhytoPET modules on each side. The PhytoPET system successfully images {sup 11}C within corn plants and allows for the dynamic measurement of {sup 11}C-sugar translocation from the leaf to the roots.

  1. Potential of PET-MRI for imaging of non-oncologic musculoskeletal disease

    PubMed Central

    Fan, Audrey P.; Gold, Garry E.

    2016-01-01

    Early detection of musculoskeletal disease leads to improved therapies and patient outcomes, and would benefit greatly from imaging at the cellular and molecular level. As it becomes clear that assessment of multiple tissues and functional processes are often necessary to study the complex pathogenesis of musculoskeletal disorders, the role of multi-modality molecular imaging becomes increasingly important. New positron emission tomography-magnetic resonance imaging (PET-MRI) systems offer to combine high-resolution MRI with simultaneous molecular information from PET to study the multifaceted processes involved in numerous musculoskeletal disorders. In this article, we aim to outline the potential clinical utility of hybrid PET-MRI to these non-oncologic musculoskeletal diseases. We summarize current applications of PET molecular imaging in osteoarthritis (OA), rheumatoid arthritis (RA), metabolic bone diseases and neuropathic peripheral pain. Advanced MRI approaches that reveal biochemical and functional information offer complementary assessment in soft tissues. Additionally, we discuss technical considerations for hybrid PET-MR imaging including MR attenuation correction, workflow, radiation dose, and quantification. PMID:28090451

  2. Tumor Lysing Genetically Engineered T Cells Loaded with Multi-Modal Imaging Agents

    NASA Astrophysics Data System (ADS)

    Bhatnagar, Parijat; Alauddin, Mian; Bankson, James A.; Kirui, Dickson; Seifi, Payam; Huls, Helen; Lee, Dean A.; Babakhani, Aydin; Ferrari, Mauro; Li, King C.; Cooper, Laurence J. N.

    2014-03-01

    Genetically-modified T cells expressing chimeric antigen receptors (CAR) exert anti-tumor effect by identifying tumor-associated antigen (TAA), independent of major histocompatibility complex. For maximal efficacy and safety of adoptively transferred cells, imaging their biodistribution is critical. This will determine if cells home to the tumor and assist in moderating cell dose. Here, T cells are modified to express CAR. An efficient, non-toxic process with potential for cGMP compliance is developed for loading high cell number with multi-modal (PET-MRI) contrast agents (Super Paramagnetic Iron Oxide Nanoparticles - Copper-64; SPION-64Cu). This can now be potentially used for 64Cu-based whole-body PET to detect T cell accumulation region with high-sensitivity, followed by SPION-based MRI of these regions for high-resolution anatomically correlated images of T cells. CD19-specific-CAR+SPIONpos T cells effectively target in vitro CD19+ lymphoma.

  3. SU-E-J-86: Lobar Lung Function Quantification by PET Galligas and CT Ventilation Imaging in Lung Cancer Patients

    SciTech Connect

    Eslick, E; Kipritidis, J; Keall, P; Bailey, D; Bailey, E

    2014-06-01

    Purpose: The purpose of this study was to quantify the lobar lung function using the novel PET Galligas ([68Ga]-carbon nanoparticle) ventilation imaging and the investigational CT ventilation imaging in lung cancer patients pre-treatment. Methods: We present results on our first three lung cancer patients (2 male, mean age 78 years) as part of an ongoing ethics approved study. For each patient a PET Galligas ventilation (PET-V) image and a pair of breath hold CT images (end-exhale and end-inhale tidal volumes) were acquired using a Siemens Biograph PET CT. CT-ventilation (CT-V) images were created from the pair of CT images using deformable image registration (DIR) algorithms and the Hounsfield Unit (HU) ventilation metric. A comparison of ventilation quantification from each modality was done on the lobar level and the voxel level. A Bland-Altman plot was used to assess the difference in mean percentage contribution of each lobe to the total lung function between the two modalities. For each patient, a voxel-wise Spearmans correlation was calculated for the whole lungs between the two modalities. Results: The Bland-Altman plot demonstrated strong agreement between PET-V and CT-V for assessment of lobar function (r=0.99, p<0.001; range mean difference: −5.5 to 3.0). The correlation between PET-V and CT-V at the voxel level was moderate(r=0.60, p<0.001). Conclusion: This preliminary study on the three patients data sets demonstrated strong agreement between PET and CT ventilation imaging for the assessment of pre-treatment lung function at the lobar level. Agreement was only moderate at the level of voxel correlations. These results indicate that CT ventilation imaging has potential for assessing pre-treatment lobar lung function in lung cancer patients.

  4. State of the art imaging of multiple myeloma: comparative review of FDG PET/CT imaging in various clinical settings.

    PubMed

    Mesguich, Charles; Fardanesh, Reza; Tanenbaum, Lawrence; Chari, Ajai; Jagannath, Sundar; Kostakoglu, Lale

    2014-12-01

    18-Flurodeoxyglucose Positron Emission Tomography with computed tomography (FDG PET/CT) and Magnetic Resonance Imaging (MRI) have higher sensitivity and specificity than whole-body X-ray (WBXR) survey in evaluating disease extent in patients with multiple myeloma (MM). Both modalities are now recommended by the Durie-Salmon Plus classification although the emphasis is more on MRI than PET/CT. The presence of extra-medullary disease (EMD) as evaluated by PET/CT imaging, initial SUVmax and number of focal lesions (FL) are deemed to be strong prognostic parameters at staging. MRI remains the most sensitive technique for the detection of diffuse bone marrow involvement in both the pre and post-therapy setting. Compression fractures are best characterized with MRI signal changes, for determining vertebroplasty candidates. While PET/CT allows for earlier and more specific evaluation of therapeutic efficacy compared to MRI, when signal abnormalities persist years after treatment. PET/CT interpretation, however, can be challenging in the vertebral column and pelvis as well as in cases with post-therapy changes. Hence, a reading approach combining the high sensitivity of MRI and superior specificity of FDG PET/CT would be preferred to increase the diagnostic accuracy. In summary, the established management methods in MM, mainly relying on biological tumor parameters should be complemented with functional imaging data, both at staging and restaging for optimal management of MM.

  5. PET/MR Imaging in Cancers of the Gastrointestinal Tract.

    PubMed

    Paspulati, Raj Mohan; Gupta, Amit

    2016-10-01

    PET/computed tomography (PET/CT) is an established hybrid imaging technique for staging and follow-up of gastrointestinal (GI) tract malignancies, especially for colorectal carcinoma. Dedicated hybrid PET/MR imaging scanners are currently available for clinical use. Although they will not replace regular use of PET/CT, they may have utility in selected cases of GI tract malignancies. The superior soft tissue contrast resolution and depiction of anatomy and the functional information obtained from diffusion-weighted imaging (DWI) provided by MR imaging in PET/MR imaging are advantages over CT of PET/CT for T staging and follow-up of rectal carcinoma and for better characterization of liver lesions. Functional information from DWI and use of liver-specific MR imaging contrast agents are an added advantage in follow-up of liver metastases after systemic and locoregional treatment. New radiotracers will improve the utility of PET/MR imaging in staging and follow-up of tumors, which may not be [18F]-2-fluoro-2-deoxy-d-glucose avid, such as hepatocellular carcinoma and neuroendocrine tumors. PET/MR imaging also has application in selected cases of cholangiocarcinoma, gallbladder cancer, and pancreatic carcinoma for initial staging and follow-up assessment.

  6. High Resolution PET Imaging Probe for the Detection, Molecular Characterization and Treatment Monitoring of Prostate Cancer

    DTIC Science & Technology

    2012-07-01

    Compton camera in nuclear medical imaging. IEEE Trans Nucl Sci 2002; 49:812–16. [15] Linhart V, Burdette D, Chessi E, et al. Spectroscopy study of...applications can be recognized in both emission modalities, SPECT and PET. Compton camera is a subspecies of SPECT, where a silicon based scatter as a MR...Introducing a Compton camera also relaxes requirements of the radiotracers used, extending the range of conceivable photon energies beyond 140.5 keV of the

  7. Advances in PET imaging of P-glycoprotein function at the blood-brain barrier.

    PubMed

    Syvänen, Stina; Eriksson, Jonas

    2013-02-20

    Efflux transporter P-glycoprotein (P-gp) at the blood-brain barrier (BBB) restricts substrate compounds from entering the brain and may thus contribute to pharmacoresistance observed in patient groups with refractory epilepsy and HIV. Altered P-gp function has also been implicated in neurodegenerative diseases such as Alzheimer's and Parkinson's disease. Positron emission tomography (PET), a molecular imaging modality, has become a promising method to study the role of P-gp at the BBB. The first PET study of P-gp function was conducted in 1998, and during the past 15 years two main categories of P-gp PET tracers have been investigated: tracers that are substrates of P-gp efflux and tracers that are inhibitors of P-gp function. PET, as a noninvasive imaging technique, allows translational research. Examples of this are preclinical investigations of P-gp function before and after administering P-gp modulating drugs, investigations in various animal and disease models, and clinical investigations regarding disease and aging. The objective of the present review is to give an overview of available PET radiotracers for studies of P-gp and to discuss how such studies can be designed. Further, the review summarizes results from PET studies of P-gp function in different central nervous system disorders.

  8. 89Zr-Labeled Paramagnetic Octreotide-Liposomes for PET-MR Imaging of Cancer

    PubMed Central

    Abou, Diane S.; Thorek, Daniel L. J.; Ramos, Nicholas N.; Pinkse, Martijn W. H.; Wolterbeek, Hubert T.; Carlin, Sean D.; Beattie, Bradley J.

    2013-01-01

    Purpose Dual-modality PET/MR platforms add a new dimension to patient diagnosis with high resolution, functional, and anatomical imaging. The full potential of this emerging hybrid modality could be realized by using a corresponding dual-modality probe. Here, we report pegylated liposome (LP) formulations, housing a MR T1 contrast agent (Gd) and the positron-emitting 89Zr (half-life: 3.27 days), for simultaneous PET and MR tumor imaging capabilities. Methods 89Zr oxophilicity was unexpectedly found advantageous for direct radiolabeling of preformed paramagnetic LPs. LPs were conjugated with octreotide to selectively target neuroendocrine tumors via human somatostatin receptor subtype 2 (SSTr2). 89Zr-Gd-LPs and octreotide-conjugated homolog were physically, chemically and biologically characterized. Results 89Zr-LPs showed reasonable stability over serum proteins and chelator challenges for proof-of-concept in vitro and in vivo investigations. Nuclear and paramagnetic tracking quantified superior SSTr2-recognition of octreotide-LP compared to controls. Conclusions This study demonstrated SSTr2-targeting specificity along with direct chelator-free 89Zr-labeling of LPs and dual PET/MR imaging properties. PMID:23224977

  9. Current and Future Lymphatic Imaging Modalities for Tumor Staging

    PubMed Central

    Gao, Kuo; Liu, Tiegang; Tariq, Imran; Sajjad, Ashif; Niu, Meiying; Liu, Guokai; Mehmood, Zahid; Tian, Guihua

    2014-01-01

    Tumor progression is supported by the lymphatic system which should be scanned efficiently for tumor staging as well as the enhanced therapeutic outcomes. Poor resolution and low sensitivity is a limitation of traditional lymphatic imaging modalities; thus new noninvasive approaches like nanocarriers, magnetic resonance imaging, positron-emission tomography, and quantum dots are advantageous. Some newer modalities, which are under development, and their potential uses will also be discussed in this review. PMID:24757671

  10. CYBPET: a cylindrical PET system for breast imaging

    NASA Astrophysics Data System (ADS)

    Karimian, A.; Thompson, C. J.; Sarkar, S.; Raisali, G.; Pani, R.; Davilu, H.; Sardari, D.

    2005-06-01

    We propose a Cylindrical Breast PET (CYBPET) system for breast imaging with patients in the prone position. An individual pendulous breast is covered by thin plastic to provide reduced pressure fixation and surrounded by the crystals inside the CYBPET ring. Each breast is imaged separately. The rest of the body is shielded properly to minimize the contribution of scattered photons from the other breast and the rest of the body. To compare the CYBPET with whole-body PET (WB-PET) the simulations of CYBPET and a WB-PET (GE-Advance) for a 10 mm tumor inside the breast with a lesion to background (breast) activity concentration of 6 to 1 were made. The noise effective count rate (NECR) of CYBPET is about twice that of WB-PET at activity concentrations less than 3.1 μCi/cc. The spatial resolution of CYBPET is better by 25% than the WB-PET.

  11. A novel 3D graph cut based co-segmentation of lung tumor on PET-CT images with Gaussian mixture models

    NASA Astrophysics Data System (ADS)

    Yu, Kai; Chen, Xinjian; Shi, Fei; Zhu, Weifang; Zhang, Bin; Xiang, Dehui

    2016-03-01

    Positron Emission Tomography (PET) and Computed Tomography (CT) have been widely used in clinical practice for radiation therapy. Most existing methods only used one image modality, either PET or CT, which suffers from the low spatial resolution in PET or low contrast in CT. In this paper, a novel 3D graph cut method is proposed, which integrated Gaussian Mixture Models (GMMs) into the graph cut method. We also employed the random walk method as an initialization step to provide object seeds for the improvement of the graph cut based segmentation on PET and CT images. The constructed graph consists of two sub-graphs and a special link between the sub-graphs which penalize the difference segmentation between the two modalities. Finally, the segmentation problem is solved by the max-flow/min-cut method. The proposed method was tested on 20 patients' PET-CT images, and the experimental results demonstrated the accuracy and efficiency of the proposed algorithm.

  12. Body-wide anatomy recognition in PET/CT images

    NASA Astrophysics Data System (ADS)

    Wang, Huiqian; Udupa, Jayaram K.; Odhner, Dewey; Tong, Yubing; Zhao, Liming; Torigian, Drew A.

    2015-03-01

    With the rapid growth of positron emission tomography/computed tomography (PET/CT)-based medical applications, body-wide anatomy recognition on whole-body PET/CT images becomes crucial for quantifying body-wide disease burden. This, however, is a challenging problem and seldom studied due to unclear anatomy reference frame and low spatial resolution of PET images as well as low contrast and spatial resolution of the associated low-dose CT images. We previously developed an automatic anatomy recognition (AAR) system [15] whose applicability was demonstrated on diagnostic computed tomography (CT) and magnetic resonance (MR) images in different body regions on 35 objects. The aim of the present work is to investigate strategies for adapting the previous AAR system to low-dose CT and PET images toward automated body-wide disease quantification. Our adaptation of the previous AAR methodology to PET/CT images in this paper focuses on 16 objects in three body regions - thorax, abdomen, and pelvis - and consists of the following steps: collecting whole-body PET/CT images from existing patient image databases, delineating all objects in these images, modifying the previous hierarchical models built from diagnostic CT images to account for differences in appearance in low-dose CT and PET images, automatically locating objects in these images following object hierarchy, and evaluating performance. Our preliminary evaluations indicate that the performance of the AAR approach on low-dose CT images achieves object localization accuracy within about 2 voxels, which is comparable to the accuracies achieved on diagnostic contrast-enhanced CT images. Object recognition on low-dose CT images from PET/CT examinations without requiring diagnostic contrast-enhanced CT seems feasible.

  13. Site-specifically labeled CA19.9-targeted immunoconjugates for the PET, NIRF, and multimodal PET/NIRF imaging of pancreatic cancer

    PubMed Central

    Houghton, Jacob L.; Zeglis, Brian M.; Abdel-Atti, Dalya; Aggeler, Robert; Sawada, Ritsuko; Agnew, Brian J.; Scholz, Wolfgang W.; Lewis, Jason S.

    2015-01-01

    Molecular imaging agents for preoperative positron emission tomography (PET) and near-infrared fluorescent (NIRF)-guided delineation of surgical margins could greatly enhance the diagnosis, staging, and resection of pancreatic cancer. PET and NIRF optical imaging offer complementary clinical applications, enabling the noninvasive whole-body imaging to localize disease and identification of tumor margins during surgery, respectively. We report the development of PET, NIRF, and dual-modal (PET/NIRF) imaging agents, using 5B1, a fully human monoclonal antibody that targets CA19.9, a well-established pancreatic cancer biomarker. Desferrioxamine (DFO) and/or a NIRF dye (FL) were conjugated to the heavy-chain glycans of 5B1, using a robust and reproducible site-specific (ss) labeling methodology to generate three constructs (ssDFO-5B1, ssFL-5B1, and ssdual-5B1) in which the immunoreactivity was not affected by the conjugation of either label. Each construct was evaluated in a s.c. xenograft model, using CA19.9-positive (BxPC3) and -negative (MIAPaCa-2) human pancreatic cancer cell lines. Each construct showed exceptional uptake and contrast in antigen-positive tumors with negligible nonspecific uptake in antigen-negative tumors. Additionally, the dual-modal construct was evaluated in an orthotopic murine pancreatic cancer model, using the human pancreatic cancer cell line, Suit-2. The ssdual-5B1 demonstrated a remarkable capacity to delineate metastases and to map the sentinel lymph nodes via tandem PET-computed tomography (PET/CT) and NIRF imaging. Fluorescence microscopy, histopathology, and autoradiography were performed on representative sections of excised tumors to visualize the distribution of the constructs within the tumors. These imaging tools have tremendous potential for further preclinical research and for clinical translation. PMID:26668398

  14. Dual-modality imaging of function and physiology

    NASA Astrophysics Data System (ADS)

    Hasegawa, Bruce H.; Iwata, Koji; Wong, Kenneth H.; Wu, Max C.; Da Silva, Angela; Tang, Hamilton R.; Barber, William C.; Hwang, Andrew B.; Sakdinawat, Anne E.

    2002-04-01

    Dual-modality imaging is a technique where computed tomography or magnetic resonance imaging is combined with positron emission tomography or single-photon computed tomography to acquire structural and functional images with an integrated system. The data are acquired during a single procedure with the patient on a table viewed by both detectors to facilitate correlation between the structural and function images. The resulting data can be useful for localization for more specific diagnosis of disease. In addition, the anatomical information can be used to compensate the correlated radionuclide data for physical perturbations such as photon attenuation, scatter radiation, and partial volume errors. Thus, dual-modality imaging provides a priori information that can be used to improve both the visual quality and the quantitative accuracy of the radionuclide images. Dual-modality imaging systems also are being developed for biological research that involves small animals. The small-animal dual-modality systems offer advantages for measurements that currently are performed invasively using autoradiography and tissue sampling. By acquiring the required data noninvasively, dual-modality imaging has the potential to allow serial studies in a single animal, to perform measurements with fewer animals, and to improve the statistical quality of the data.

  15. Multi-Modal Imaging with a Toolbox of Influenza A Reporter Viruses.

    PubMed

    Tran, Vy; Poole, Daniel S; Jeffery, Justin J; Sheahan, Timothy P; Creech, Donald; Yevtodiyenko, Aleksey; Peat, Andrew J; Francis, Kevin P; You, Shihyun; Mehle, Andrew

    2015-10-13

    Reporter viruses are useful probes for studying multiple stages of the viral life cycle. Here we describe an expanded toolbox of fluorescent and bioluminescent influenza A reporter viruses. The enhanced utility of these tools enabled kinetic studies of viral attachment, infection, and co-infection. Multi-modal bioluminescence and positron emission tomography-computed tomography (PET/CT) imaging of infected animals revealed that antiviral treatment reduced viral load, dissemination, and inflammation. These new technologies and applications will dramatically accelerate in vitro and in vivo influenza virus studies.

  16. Sparsity-constrained PET image reconstruction with learned dictionaries

    NASA Astrophysics Data System (ADS)

    Tang, Jing; Yang, Bao; Wang, Yanhua; Ying, Leslie

    2016-09-01

    PET imaging plays an important role in scientific and clinical measurement of biochemical and physiological processes. Model-based PET image reconstruction such as the iterative expectation maximization algorithm seeking the maximum likelihood solution leads to increased noise. The maximum a posteriori (MAP) estimate removes divergence at higher iterations. However, a conventional smoothing prior or a total-variation (TV) prior in a MAP reconstruction algorithm causes over smoothing or blocky artifacts in the reconstructed images. We propose to use dictionary learning (DL) based sparse signal representation in the formation of the prior for MAP PET image reconstruction. The dictionary to sparsify the PET images in the reconstruction process is learned from various training images including the corresponding MR structural image and a self-created hollow sphere. Using simulated and patient brain PET data with corresponding MR images, we study the performance of the DL-MAP algorithm and compare it quantitatively with a conventional MAP algorithm, a TV-MAP algorithm, and a patch-based algorithm. The DL-MAP algorithm achieves improved bias and contrast (or regional mean values) at comparable noise to what the other MAP algorithms acquire. The dictionary learned from the hollow sphere leads to similar results as the dictionary learned from the corresponding MR image. Achieving robust performance in various noise-level simulation and patient studies, the DL-MAP algorithm with a general dictionary demonstrates its potential in quantitative PET imaging.

  17. Sparsity-constrained PET image reconstruction with learned dictionaries.

    PubMed

    Tang, Jing; Yang, Bao; Wang, Yanhua; Ying, Leslie

    2016-09-07

    PET imaging plays an important role in scientific and clinical measurement of biochemical and physiological processes. Model-based PET image reconstruction such as the iterative expectation maximization algorithm seeking the maximum likelihood solution leads to increased noise. The maximum a posteriori (MAP) estimate removes divergence at higher iterations. However, a conventional smoothing prior or a total-variation (TV) prior in a MAP reconstruction algorithm causes over smoothing or blocky artifacts in the reconstructed images. We propose to use dictionary learning (DL) based sparse signal representation in the formation of the prior for MAP PET image reconstruction. The dictionary to sparsify the PET images in the reconstruction process is learned from various training images including the corresponding MR structural image and a self-created hollow sphere. Using simulated and patient brain PET data with corresponding MR images, we study the performance of the DL-MAP algorithm and compare it quantitatively with a conventional MAP algorithm, a TV-MAP algorithm, and a patch-based algorithm. The DL-MAP algorithm achieves improved bias and contrast (or regional mean values) at comparable noise to what the other MAP algorithms acquire. The dictionary learned from the hollow sphere leads to similar results as the dictionary learned from the corresponding MR image. Achieving robust performance in various noise-level simulation and patient studies, the DL-MAP algorithm with a general dictionary demonstrates its potential in quantitative PET imaging.

  18. MR-Based Cardiac and Respiratory Motion-Compensation Techniques for PET-MR Imaging.

    PubMed

    Munoz, Camila; Kolbitsch, Christoph; Reader, Andrew J; Marsden, Paul; Schaeffter, Tobias; Prieto, Claudia

    2016-04-01

    Cardiac and respiratory motion cause image quality degradation in PET imaging, affecting diagnostic accuracy of the images. Whole-body simultaneous PET-MR scanners allow for using motion information estimated from MR images to correct PET data and produce motion-compensated PET images. This article reviews methods that have been proposed to estimate motion from MR images and different techniques to include this information in PET reconstruction, in order to overcome the problem of cardiac and respiratory motion in PET-MR imaging. MR-based motion correction techniques significantly increase lesion detectability and contrast, and also improve accuracy of uptake values in PET images.

  19. Motion based X-ray imaging modality.

    PubMed

    Szigeti, Krisztián; Máthé, Domokos; Osváth, Szabolcs

    2014-10-01

    A new X-ray imaging method (patent pending) was developed to visualize function-related motion information. We modify existing X-ray imaging methods to provide four images without increasing the necessary measurement time or radiation dose. The most important of these images is a new "kinetic" image that represents motions inside the object or living body. The motion-based contrast of the kinetic image can help visualize details that were not accessible before. The broad range of the movements and high sensitivity of the method are illustrated by imaging the mechanics of a working clock and the chest of a living African clawed frog (Xenopus laevis). The heart, valves, aorta, and lungs of the frog are clearly visualized in spite of the low soft tissue contrast of the animal. The new technology also reconstructs a "static" image similar to the existing conventional X-ray image. The static image shows practically the same information as the conventional image. The new technology presents two more images which show the point-wise errors of the static and kinetic images. This technique gives a better estimation of errors than present methods because it is based entirely on measured data. The new technology could be used in imaging cardiopulmonary movements, nondestructive testing, or port security screening.

  20. Whole-body FDG-PET imaging for staging of Hodgkin`s disease and lymphoma

    SciTech Connect

    Hoh, C.K.; Glaspy, J.; Rosen, P.

    1997-03-01

    Accurate staging of Hodgkin`s disease (HD) and non-Hodgkin`s lymphoma (NHL) is important for treatment management. In this study, the utility of 2-[{sup 18}F]fluoro-2-deoxy-D-glucose (FDG) wholebody PET was evaluated as an imaging modality for initial staging or restaging of 7 HD and 11 NHL patients. Whole-body PET-based staging results were compared to the patient`s clinical stage based on conventional staging studies, which included combinations of CT of the chest, abdomen and pelvis, MRI scans, gallium scans, lymphangiograms, staging laparatomies and bone scans. Accurate staging was performed in 17 of 18 patients using a whole-body PET-based staging algorithm compared to the conventional staging algorithm in 15 of 18 patients. In 5 of 18 patients, whole-body PET-based staging showed additional lesions not detected by conventional staging modalities, whereas conventional staging demonstrated additional lesions in 4 of 18 patients not detected by whole-body PET. The total cost of conventional staging was $66,292 for 16 CT chest scans, 16 CT abdominal/pelvis scans, three limited MRI scans, four bone scans, give gallium scans, two laparotomies and one lymphangiogram. In contrast, scans cost $36,250 for 18 whole-body PET studies and additional selected correlative studies: one plain film radiograph, one limited CT, one bone marrow san, one upper GI and one endoscopy. A whole-body FDG-PET-based staging algorithm may be an accurate and cost-effective method for staging or restaging HD and NHL. 10 refs., 7 figs., 2 tabs.

  1. Improving PET imaging for breast cancer using Virtual Pinhole PET half ring insert

    PubMed Central

    Mathews, Aswin John; Komarov, Sergey; Wu, Heyu; O’Sullivan, Joseph A.; Tai, Yuan-Chuan

    2013-01-01

    A PET insert with detector having smaller crystals and placed near a region of interest in a conventional PET scanner can improve image resolution locally due to the Virtual-Pinhole PET (VP-PET) effect. This improvement is from the higher spatial sampling of the imaging area near the detector. We have built a prototype half-ring PET insert for head-and-neck cancer imaging applications. In this paper, we extend the use of the insert to breast imaging and show that such a system provides high resolution images of breast and axillary lymph nodes while maintaining the full imaging field of view capability of a clinical PET scanner. We characterize the resolution and contrast recovery for tumors across the imaging field of view. First, we model the system using Monte Carlo methods to determine its theoretical limit of improvement. Simulations were conducted with hot spherical tumors embedded in background activity at tumor-to-background contrast ranging from 3:1 to 12:1. Tumors are arranged in a Derenzo-like pattern with their diameters ranging from 2 to 12 mm. Experimental studies were performed using a chest phantom with cylindrical breast attachment. Tumors of different sizes arranged in a Derenzo-like pattern with tumor-to- background ratio of 6:1 are inserted into the breast phantom. Imaging capability of mediastinum and axillary lymph nodes is explored. Both Monte Carlo simulations and experiment show clear improvement in image resolution and contrast recovery with VP-PET half ring insert. The degree of improvement in resolution and contrast recovery depends on location of the tumor. The full field of view imaging capability is shown to be maintained. Minor artifacts are introduced in certain regions. PMID:23999026

  2. Update on time-of-flight PET imaging

    PubMed Central

    Surti, Suleman

    2015-01-01

    Time-of-flight (TOF) PET was initially introduced in the early days of PET. TOF PET scanners developed in the 1980s had limited sensitivity and spatial resolution, operated in 2D mode with septa, and used analytic image reconstruction methods. Current generation of TOF PET scanners have the highest sensitivity and spatial resolution ever achieved in commercial whole-body PET, operate in fully-3D mode, and use iterative reconstruction with full system modeling. Previously, it was shown that TOF provides a gain in image signal-to-noise-ratio (SNR) that is proportional to the square root of the object size divided by the system timing resolution. With oncologic studies being the primary application of PET, more recent work has shown that in modern TOF PET scanners there is an improved trade-off between lesion contrast, image noise, and total imaging time, leading to a combination of improved lesion detectability, reduced scan time or injected dose, and more accurate and precise lesion uptake measurement. The benefit of TOF PET is also higher for heavier patients, which leads to a more uniform clinical performance over all patient sizes. PMID:25525181

  3. Thoracic cancer imaging with PET/CT in radiation oncology

    NASA Astrophysics Data System (ADS)

    Chi, Pai-Chun Melinda

    Significance. Respiratory motion has been shown to cause artifacts in PET/CT imaging. This breathing artifact can have a significant impact on PET quantification and it can lead to large uncertainties when using PET for radiation therapy planning. We have demonstrated a promising solution to resolve the breathing artifact by acquiring respiration-averaged CT (ACT) for PET/CT. The purpose of this work was to optimize the ACT acquisition for clinical implementation and to evaluate the impact of ACT on PET/CT quantification. The hypothesis was that ACT is an effective method in removing the breathing artifact when compared to our current clinical protocol. Methods. Phase and cine approaches for acquiring ACT were investigated and the results of these two approaches were compared to the ACT generated from clinical 4DCT data sets (abbreviated as ACT10phs ). In the phase approach, ACT was generated based on combinations of selected respiratory phases; in the cine approach, ACT was generated based on cine images acquired over a fixed cine duration. The phase combination and cine duration that best approximated the ACT10phs were determined to be the optimized scanning parameters. 216 thoracic PET/CT patients were scanned with both current clinical and the ACT protocols. The effects of ACT on PET/CT quantification were assessed by comparing clinical PET/CT and ACT PET/CT using 3 metrics: PET/CT image alignment, maximum standardized uptake value (SUVmax), and threshold segmented gross tumor volume (GTV). Results. ACT10phs can be best approximated to within 2% of SUV variation by phase averaging based on 4 representative phases, and to within 3% by cine image averaging based on >3s of cine duration. We implemented the cine approach on the PET/CT scanners and acquired 216 patient data sets. 68% of patients had breathing artifacts in their clinical PET/CT and the artifacts were removed/reduced in all corresponding ACT PET/CT. PET/CT quantification for lesions <50 cm3 and

  4. PET IMAGING STUDIES IN DRUG ABUSE RESEARCH.

    SciTech Connect

    Fowler, J.S.; Volkow, N.D.; Ding, Y.S.; Logan, J.; Wang, G.J.

    2001-01-29

    There is overwhelming evidence that addiction is a disease of the brain (Leshner, 1997). Yet public perception that addiction is a reflection of moral weakness or a lack of willpower persists. The insidious consequence of this perception is that we lose sight of the fact that there are enormous medical consequences of addiction including the fact that a large fraction of the total deaths from cancer and heart disease are caused by smoking addiction. Ironically the medical school that educates physicians in addiction medicine and the cancer hospital that has a smoking cessation clinic are vanishingly rare and efforts at harm reduction are frequently met with a public indignation. Meanwhile the number of people addicted to substances is enormous and increasing particularly the addictions to cigarettes and alcohol. It is particularly tragic that addiction usually begins in adolescence and becomes a chronic relapsing problem and there are basically no completely effective treatments. Clearly we need to understand how drugs of abuse affect the brain and we need to be creative in using this information to develop effective treatments. Imaging technologies have played a major role in the conceptualization of addiction as a disease of the brain (Fowler et al., 1998a; Fowler et al., 1999a). New knowledge has been driven by advances in radiotracer design and chemistry and positron emission tomography (PET) instrumentation and the integration of these scientific tools with the tools of biochemistry, pharmacology and medicine. This topic cuts across the medical specialties of neurology, psychiatry, cancer and heart disease because of the high medical, social and economic toll that drugs of abuse, including and especially the legal drugs, cigarettes and alcohol, take on society. In this chapter we will begin by highlighting the important role that chemistry has played in making it possible to quantitatively image the movement of drugs as well as their effects on the human brain

  5. A statistical method for lung tumor segmentation uncertainty in PET images based on user inference.

    PubMed

    Zheng, Chaojie; Wang, Xiuying; Feng, Dagan

    2015-01-01

    PET has been widely accepted as an effective imaging modality for lung tumor diagnosis and treatment. However, standard criteria for delineating tumor boundary from PET are yet to develop largely due to relatively low quality of PET images, uncertain tumor boundary definition, and variety of tumor characteristics. In this paper, we propose a statistical solution to segmentation uncertainty on the basis of user inference. We firstly define the uncertainty segmentation band on the basis of segmentation probability map constructed from Random Walks (RW) algorithm; and then based on the extracted features of the user inference, we use Principle Component Analysis (PCA) to formulate the statistical model for labeling the uncertainty band. We validated our method on 10 lung PET-CT phantom studies from the public RIDER collections [1] and 16 clinical PET studies where tumors were manually delineated by two experienced radiologists. The methods were validated using Dice similarity coefficient (DSC) to measure the spatial volume overlap. Our method achieved an average DSC of 0.878 ± 0.078 on phantom studies and 0.835 ± 0.039 on clinical studies.

  6. Denoising of PET images by context modelling using local neighbourhood correlation

    NASA Astrophysics Data System (ADS)

    Huerga, Carlos; Castro, Pablo; Corredoira, Eva; Coronado, Monica; Delgado, Victor; Guibelalde, Eduardo

    2017-01-01

    Positron emission tomography (PET) images are characterised by low signal-to-noise ratio and blurred edges when compared with other image modalities. It is therefore advisable to use noise reduction methods for qualitative and quantitative analyses. Given the importance of the maximum and mean uptake values, it is necessary to avoid signal loss, which could modify the clinical significance. This paper proposes a method of non-linear image denoising for PET. It is based on spatially adaptive wavelet-shrinkage and uses context modelling, which explicitly considers the correlation between neighbouring pixels. This context modelling is able to maintain the uptake values and preserve the edges in significant regions. The algorithm is proposed as an alternative to the usual filtering that is performed after reconstruction.

  7. A study of artefacts in simultaneous PET and MR imaging using a prototype MR compatible PET scanner.

    PubMed

    Slates, R B; Farahani, K; Shao, Y; Marsden, P K; Taylor, J; Summers, P E; Williams, S; Beech, J; Cherry, S R

    1999-08-01

    We have assessed the possibility of artefacts that can arise in attempting to perform simultaneous positron emission tomography (PET) and magnetic resonance imaging (MRI) using a small prototype MR compatible PET scanner (McPET). In these experiments, we examine MR images for any major artefacts or loss in image quality due to inhomogeneities in the magnetic field, radiofrequency interference or susceptibility effects caused by operation of the PET system inside the MR scanner. In addition, possible artefacts in the PET images caused by the static and time-varying magnetic fields or radiofrequency interference from the MR system were investigated. Biological tissue and a T2-weighted spin echo sequence were used to examine susceptibility artefacts due to components of the McPET scanner (scintillator, optical fibres) situated in the MR field of view. A range of commonly used MR pulse sequences was studied while acquiring PET data to look for possible artefacts in either the PET or MR images. Other than a small loss in signal-to-noise using gradient echo sequences, there was no significant interaction between the two imaging systems. Simultaneous PET and MR imaging of simple phantoms was also carried out in different MR systems with field strengths ranging from 0.2 to 4.7 T. The results of these studies demonstrate that it is possible to acquire PET and MR images simultaneously, without any significant artefacts or loss in image quality, using our prototype MR compatible PET scanner.

  8. Advances in image-guided radiation therapy-the role of PET-CT

    SciTech Connect

    Heron, Dwight E. . E-mail: heronD2@upmc.edu; Smith, Ryan P.; Andrade, Regiane S.

    2006-04-01

    In the era of image-guided radiation therapy (IGRT), the greatest challenge remains target delineation, as the opportunity to maximize cures while simultaneously decreasing radiation dose to the surrounding normal tissues is to be realized. Over the last 2 decades, technological advances in radiographic imaging, biochemistry, and molecular biology have played an increasing role in radiation treatment planning, delivery, and evaluation of response. Previously, fluoroscopy formed the basis of radiation treatment planning. Beginning in the late 1980s, computed tomography (CT) has become the basis for modern radiation treatment planning and delivery, coincident with the rise of 3-dimensional conformal radiation therapy (3DCRT). Additionally, multi-modality anatomic imaging registration was the solution pursued to augment delineation of tumors and surrounding structures on CT-based treatment planning. Although these imaging modalities provide the customary anatomic details necessary for radiation treatment planning, they have limitations, including difficulty with identification of small tumor deposits, tumor extension, and distinction from scar tissues. To overcome these limitations, PET and, more recently, PET-CT have been innovative regarding the extent of disease appraisal, target delineation in the treatment planning, and assessment of therapy response. We review the role of functional imaging in IGRT as it reassures transformations on the field of radiation oncology. As we move toward the era of IGRT, the use of multi-modality imaging fusion, and the introduction of more sensitive and specific PET-CT tracers may further assist target definition. Furthermore, the potential to predict early outcome or even detect early recurrence of tumor, may allow for the tailoring of intervention in cancer patients. The convergence of a biological target volume, and perhaps multi-tracer tumor, molecular, and genetic profile tumors will probably be vital in cancer treatment

  9. A web-based image viewer for multiple PET-CT follow-up studies.

    PubMed

    Haraguchi, Daiki; Kim, Jinman; Kumar, Ashnil; Constantinescu, Liviu; Wen, Lingfeng; Feng, David Dagan

    2011-01-01

    There exist many viewers for single-modal medical images that are efficient and are equipped with powerful analysis tools. However, there is a distinct lack of efficient image viewers for multi-modality images, particularly for displaying multiple follow-up studies that depict a patient's response to treatment over time. Such viewers would be required to display large amounts of image data. In this study, we present the TAGIGEN viewer--a web-based image viewer designed specifically for the visualisation of multi-modality follow-up studies. We innovate by defining a series of dynamically generated image grid layouts that display sets of related images together in order to improve the ability to compare and assimilate the myriad images. We adopted a web-based client-server image streaming technology, thus enabling interactive navigation of the images in a computationally efficient manner. Furthermore, our web-based approach is interoperable and requires no software installation. We evaluated the ability of our viewer in displaying and understanding a patient's follow-up images in a case study with combined positron emission tomography and computed tomography (PET-CT) follow-up scans. We conducted a usability survey on 10 participants to measure the usefulness of our viewer, used as an outpatient viewer e.g. viewer designed for use by the patients, in tracking a patient's disease state across four PET-CT studies. Our initial results suggest that our viewer was able to efficiently visualise the patient data over time, and that the web-based implementation was fast (loading on average within 5.6 seconds with real-time navigation) and easy to use (overall survey score higher than 4 / 5).

  10. SU-E-J-275: Review - Computerized PET/CT Image Analysis in the Evaluation of Tumor Response to Therapy

    SciTech Connect

    Lu, W; Wang, J; Zhang, H

    2015-06-15

    Purpose: To review the literature in using computerized PET/CT image analysis for the evaluation of tumor response to therapy. Methods: We reviewed and summarized more than 100 papers that used computerized image analysis techniques for the evaluation of tumor response with PET/CT. This review mainly covered four aspects: image registration, tumor segmentation, image feature extraction, and response evaluation. Results: Although rigid image registration is straightforward, it has been shown to achieve good alignment between baseline and evaluation scans. Deformable image registration has been shown to improve the alignment when complex deformable distortions occur due to tumor shrinkage, weight loss or gain, and motion. Many semi-automatic tumor segmentation methods have been developed on PET. A comparative study revealed benefits of high levels of user interaction with simultaneous visualization of CT images and PET gradients. On CT, semi-automatic methods have been developed for only tumors that show marked difference in CT attenuation between the tumor and the surrounding normal tissues. Quite a few multi-modality segmentation methods have been shown to improve accuracy compared to single-modality algorithms. Advanced PET image features considering spatial information, such as tumor volume, tumor shape, total glycolytic volume, histogram distance, and texture features have been found more informative than the traditional SUVmax for the prediction of tumor response. Advanced CT features, including volumetric, attenuation, morphologic, structure, and texture descriptors, have also been found advantage over the traditional RECIST and WHO criteria in certain tumor types. Predictive models based on machine learning technique have been constructed for correlating selected image features to response. These models showed improved performance compared to current methods using cutoff value of a single measurement for tumor response. Conclusion: This review showed that

  11. Quantitative imaging of (124)I with PET/ CT in pretherapy lesion dosimetry. Effects impairing image quantification and their corrections.

    PubMed

    Jentzen, W; Freudenberg, L; Bockisch, A

    2011-02-01

    Iodine-131-labelled agents are successfully used in cancer treatment. In the pretherapy dosimetry approach, positron emission tomography/computed tomography (PET/CT) using (124)I provides a modality to estimate absorbed dose to tumours and can be considered as the preferred imaging method for this purpose in (131)I radiopharmaceutical therapies. For accurate dosimetry, serial measurements of activity concentrations (ACs) over an appropriate time period are necessary. Consequently, accurate AC determination is of paramount importance in PET/CT-based lesion dosimetry using (124)I-labelled agents. After presenting an historical overview of (124)I clinical application, this review focuses on factors impairing PET image quantification accuracy and on methods of correcting for these effects. Specifically, the emission of prompt gamma photons in the (124)I decay process that are detected in coincidence with each other and with the annihilation photon, and the low (124)I positron branching ration of only 23% raise concerns regarding image quantification accuracy. This review discusses this prompt gamma effect, its impact and approaches to correct for this phenomenon. In (124)I lesion dosimetry, recovery coefficients (RCs) are commonly used to compensate primarily for partial-volume effect but also, in a simplistic way, for prompt gamma coincidence effect; the main methodological factors affecting the RC-corrected (124)I AC are described. Finally, special issues in image (124)I quantification are reviewed, including coadministration of high therapeutic activities of 131I, shine-through artefact, and transmission-contamination effect occurring in stand-alone PET systems.

  12. Quantifying hypoxia in human cancers using static PET imaging.

    PubMed

    Taylor, Edward; Yeung, Ivan; Keller, Harald; Wouters, Bradley G; Milosevic, Michael; Hedley, David W; Jaffray, David A

    2016-11-21

    Compared to FDG, the signal of (18)F-labelled hypoxia-sensitive tracers in tumours is low. This means that in addition to the presence of hypoxic cells, transport properties contribute significantly to the uptake signal in static PET images. This sensitivity to transport must be minimized in order for static PET to provide a reliable standard for hypoxia quantification. A dynamic compartmental model based on a reaction-diffusion formalism was developed to interpret tracer pharmacokinetics and applied to static images of FAZA in twenty patients with pancreatic cancer. We use our model to identify tumour properties-well-perfused without substantial necrosis or partitioning-for which static PET images can reliably quantify hypoxia. Normalizing the measured activity in a tumour voxel by the value in blood leads to a reduction in the sensitivity to variations in 'inter-corporal' transport properties-blood volume and clearance rate-as well as imaging study protocols. Normalization thus enhances the correlation between static PET images and the FAZA binding rate K 3, a quantity which quantifies hypoxia in a biologically significant way. The ratio of FAZA uptake in spinal muscle and blood can vary substantially across patients due to long muscle equilibration times. Normalized static PET images of hypoxia-sensitive tracers can reliably quantify hypoxia for homogeneously well-perfused tumours with minimal tissue partitioning. The ideal normalizing reference tissue is blood, either drawn from the patient before PET scanning or imaged using PET. If blood is not available, uniform, homogeneously well-perfused muscle can be used. For tumours that are not homogeneously well-perfused or for which partitioning is significant, only an analysis of dynamic PET scans can reliably quantify hypoxia.

  13. Quantifying hypoxia in human cancers using static PET imaging

    NASA Astrophysics Data System (ADS)

    Taylor, Edward; Yeung, Ivan; Keller, Harald; Wouters, Bradley G.; Milosevic, Michael; Hedley, David W.; Jaffray, David A.

    2016-11-01

    Compared to FDG, the signal of 18F-labelled hypoxia-sensitive tracers in tumours is low. This means that in addition to the presence of hypoxic cells, transport properties contribute significantly to the uptake signal in static PET images. This sensitivity to transport must be minimized in order for static PET to provide a reliable standard for hypoxia quantification. A dynamic compartmental model based on a reaction-diffusion formalism was developed to interpret tracer pharmacokinetics and applied to static images of FAZA in twenty patients with pancreatic cancer. We use our model to identify tumour properties—well-perfused without substantial necrosis or partitioning—for which static PET images can reliably quantify hypoxia. Normalizing the measured activity in a tumour voxel by the value in blood leads to a reduction in the sensitivity to variations in ‘inter-corporal’ transport properties—blood volume and clearance rate—as well as imaging study protocols. Normalization thus enhances the correlation between static PET images and the FAZA binding rate K 3, a quantity which quantifies hypoxia in a biologically significant way. The ratio of FAZA uptake in spinal muscle and blood can vary substantially across patients due to long muscle equilibration times. Normalized static PET images of hypoxia-sensitive tracers can reliably quantify hypoxia for homogeneously well-perfused tumours with minimal tissue partitioning. The ideal normalizing reference tissue is blood, either drawn from the patient before PET scanning or imaged using PET. If blood is not available, uniform, homogeneously well-perfused muscle can be used. For tumours that are not homogeneously well-perfused or for which partitioning is significant, only an analysis of dynamic PET scans can reliably quantify hypoxia.

  14. Counting Rate Characteristics and Image Distortion in Preclinical PET Imaging During Radiopharmaceutical Therapy.

    PubMed

    Mellhammar, Emma; Dahlbom, Magnus; Axelsson, Johan; Strand, Sven-Erik

    2016-12-01

    PET may provide important information on the response during radiopharmaceutical therapy (RPT). Emission of radiation from the RPT radionuclide may disturb coincidence detection and impair image resolution. In this study, we tested the feasibility of performing intratherapeutic PET on 3 preclinical PET systems.

  15. Three-dimensional imaging modalities in endodontics

    PubMed Central

    Mao, Teresa

    2014-01-01

    Recent research in endodontics has highlighted the need for three-dimensional imaging in the clinical arena as well as in research. Three-dimensional imaging using computed tomography (CT) has been used in endodontics over the past decade. Three types of CT scans have been studied in endodontics, namely cone-beam CT, spiral CT, and peripheral quantitative CT. Contemporary endodontics places an emphasis on the use of cone-beam CT for an accurate diagnosis of parameters that cannot be visualized on a two-dimensional image. This review discusses the role of CT in endodontics, pertaining to its importance in the diagnosis of root canal anatomy, detection of peri-radicular lesions, diagnosis of trauma and resorption, presurgical assessment, and evaluation of the treatment outcome. PMID:25279337

  16. Three-dimensional imaging modalities in endodontics.

    PubMed

    Mao, Teresa; Neelakantan, Prasanna

    2014-09-01

    Recent research in endodontics has highlighted the need for three-dimensional imaging in the clinical arena as well as in research. Three-dimensional imaging using computed tomography (CT) has been used in endodontics over the past decade. Three types of CT scans have been studied in endodontics, namely cone-beam CT, spiral CT, and peripheral quantitative CT. Contemporary endodontics places an emphasis on the use of cone-beam CT for an accurate diagnosis of parameters that cannot be visualized on a two-dimensional image. This review discusses the role of CT in endodontics, pertaining to its importance in the diagnosis of root canal anatomy, detection of peri-radicular lesions, diagnosis of trauma and resorption, presurgical assessment, and evaluation of the treatment outcome.

  17. PET/CT for radiotherapy: image acquisition and data processing.

    PubMed

    Bettinardi, V; Picchio, M; Di Muzio, N; Gianolli, L; Messa, C; Gilardi, M C

    2010-10-01

    This paper focuses on acquisition and processing methods in positron emission tomography/computed tomography (PET/CT) for radiotherapy (RT) applications. The recent technological evolutions of PET/CT systems are described. Particular emphasis is dedicated to the tools needed for the patient positioning and immobilization, to be used in PET/CT studies as well as during RT treatment sessions. The effect of organ and lesion motion due to patient's respiration on PET/CT imaging is discussed. Breathing protocols proposed to minimize PET/CT spatial mismatches in relation to respiratory movements are illustrated. The respiratory gated (RG) 4D-PET/CT techniques, developed to measure and compensate for organ and lesion motion, are then introduced. Finally a description is provided of different acquisition and data processing techniques, implemented with the aim at improving: i) image quality and quantitative accuracy of PET images, and ii) target volume definition and treatment planning in RT, by using specific and personalised motion information.

  18. Towards optimal imaging with PET: an in silico feasibility study.

    PubMed

    McNamara, A L; Toghyani, M; Gillam, J E; Wu, K; Kuncic, Z

    2014-12-21

    The efficacy of Positron Emission Tomography (PET) imaging relies fundamentally on the ability of the system to accurately identify true coincidence events. With existing systems, this is currently accomplished with an energy acceptance criterion followed by correction techniques to remove suspected false coincidence events. These corrections generally result in signal and contrast loss and thus limit the PET system's ability to achieve optimum image quality. A key property of annihilation radiation is that the photons are polarised with respect to each other. This polarisation correlation offers a potentially powerful discriminator, independent of energy, to accurately identify true events. In this proof of concept study, we investigate how photon polarisation information can be exploited in PET imaging by developing a method to discriminate true coincidences using the polarisation correlation of annihilation pairs. We implement this method using a Geant4 PET simulation of a GE Advance/Discovery LS system and demonstrate the potential advantages of the polarisation coincidence selection method over a standard energy criterion method. Current PET ring detectors are not capable of exploiting the polarisation correlation of the photon pairs. Compton PET systems, however are promising candidates for this application. We demonstrate the feasibility of a two-component Compton camera system in identifying true coincidences with Monte Carlo simulations. Our study demonstrates the potential of improving signal gain using polarisation, particularly for high photon emission rates. We also demonstrate the ability of the Compton camera at exploiting this polarisation correlation in PET.

  19. Towards optimal imaging with PET: an in silico feasibility study

    NASA Astrophysics Data System (ADS)

    McNamara, A. L.; Toghyani, M.; Gillam, J. E.; Wu, K.; Kuncic, Z.

    2014-12-01

    The efficacy of Positron Emission Tomography (PET) imaging relies fundamentally on the ability of the system to accurately identify true coincidence events. With existing systems, this is currently accomplished with an energy acceptance criterion followed by correction techniques to remove suspected false coincidence events. These corrections generally result in signal and contrast loss and thus limit the PET system’s ability to achieve optimum image quality. A key property of annihilation radiation is that the photons are polarised with respect to each other. This polarisation correlation offers a potentially powerful discriminator, independent of energy, to accurately identify true events. In this proof of concept study, we investigate how photon polarisation information can be exploited in PET imaging by developing a method to discriminate true coincidences using the polarisation correlation of annihilation pairs. We implement this method using a Geant4 PET simulation of a GE Advance/Discovery LS system and demonstrate the potential advantages of the polarisation coincidence selection method over a standard energy criterion method. Current PET ring detectors are not capable of exploiting the polarisation correlation of the photon pairs. Compton PET systems, however are promising candidates for this application. We demonstrate the feasibility of a two-component Compton camera system in identifying true coincidences with Monte Carlo simulations. Our study demonstrates the potential of improving signal gain using polarisation, particularly for high photon emission rates. We also demonstrate the ability of the Compton camera at exploiting this polarisation correlation in PET.

  20. Positron emission tomography (PET) for cholangiocarcinoma

    PubMed Central

    Breitenstein, S.; Apestegui, C.

    2008-01-01

    The combination of positron emission tomography (PET) with computed tomography (PET-CT) provides simultaneous metabolic and anatomic information on tumors in the same imaging session. Sensitivity of PET/PET-CT is higher for intrahepatic (>90%) than for extrahepatic cholangiocarcinoma (CCA) (about 60%). The detection rate of distant metastasis is 100%. PET, and particularly PET-CT, improves the results and impacts on the oncological management in CCA compared with other imaging modalities. Therefore, PET-CT is recommended in the preoperative staging of intrahepatic (strength of recommendation: moderate) and extrahepatic (strength of recommendation: low) CCA. PMID:18773069

  1. PET radiopharmaceuticals for imaging of tumor hypoxia: a review of the evidence

    PubMed Central

    Lopci, Egesta; Grassi, Ilaria; Chiti, Arturo; Nanni, Cristina; Cicoria, Gianfranco; Toschi, Luca; Fonti, Cristina; Lodi, Filippo; Mattioli, Sandro; Fanti, Stefano

    2014-01-01

    Hypoxia is a pathological condition arising in living tissues when oxygen supply does not adequately cover the cellular metabolic demand. Detection of this phenomenon in tumors is of the utmost clinical relevance because tumor aggressiveness, metastatic spread, failure to achieve tumor control, increased rate of recurrence, and ultimate poor outcome are all associated with hypoxia. Consequently, in recent decades there has been increasing interest in developing methods for measurement of oxygen levels in tumors. Among the image-based modalities for hypoxia assessment, positron emission tomography (PET) is one of the most extensively investigated based on the various advantages it offers, i.e., broad range of radiopharmaceuticals, good intrinsic resolution, three-dimensional tumor representation, possibility of semiquantification/quantification of the amount of hypoxic tumor burden, overall patient friendliness, and ease of repetition. Compared with the other non-invasive techniques, the biggest advantage of PET imaging is that it offers the highest specificity for detection of hypoxic tissue. Starting with the 2-nitroimidazole family of compounds in the early 1980s, a great number of PET tracers have been developed for the identification of hypoxia in living tissue and solid tumors. This paper provides an overview of the principal PET tracers applied in cancer imaging of hypoxia and discusses in detail their advantages and pitfalls. PMID:24982822

  2. Accelerating Image Reconstruction in Dual-Head PET System by GPU and Symmetry Properties

    PubMed Central

    Chou, Cheng-Ying; Kao, Yu-Jiun; Wang, Weichung; Kao, Chien-Min; Chen, Chin-Tu

    2012-01-01

    Positron emission tomography (PET) is an important imaging modality in both clinical usage and research studies. We have developed a compact high-sensitivity PET system that consisted of two large-area panel PET detector heads, which produce more than 224 million lines of response and thus request dramatic computational demands. In this work, we employed a state-of-the-art graphics processing unit (GPU), NVIDIA Tesla C2070, to yield an efficient reconstruction process. Our approaches ingeniously integrate the distinguished features of the symmetry properties of the imaging system and GPU architectures, including block/warp/thread assignments and effective memory usage, to accelerate the computations for ordered subset expectation maximization (OSEM) image reconstruction. The OSEM reconstruction algorithms were implemented employing both CPU-based and GPU-based codes, and their computational performance was quantitatively analyzed and compared. The results showed that the GPU-accelerated scheme can drastically reduce the reconstruction time and thus can largely expand the applicability of the dual-head PET system. PMID:23300527

  3. FDG PET Imaging in Pneumocystis Pneumonia.

    PubMed

    Kono, Masanori; Yamashita, Hiroyuki; Kubota, Kazuo; Kano, Toshikazu; Mimori, Akio

    2015-08-01

    A 69-year-old woman with rheumatoid arthritis and pleuritis presented with dyspnea. On admission, she was afebrile and had an oxygen saturation of 97% on ambient air. Chest radiography and CT revealed only subtle ground-glass opacities. However, FDG PET revealed pathological uptake in both lungs. A diagnosis of Pneumocystis pneumonia was made based on a positive β-D-glucan assay and polymerase chain reaction amplification of Pneumocystis jirovecii from the sputum. Posttreatment FDG PET revealed resolution of the previously noted uptake. This case illustrates that FDG PET can be used to diagnose Pneumocystis pneumonia when the CT findings are equivocal.

  4. Quantitative [18F]-FMISO- PET imaging shows reduction of hypoxia following trastuzumab in a murine model of HER2+ breast cancer

    PubMed Central

    Sorace, Anna G.; Syed, Anum K.; Barnes, Stephanie L.; Quarles, C. Chad; Sanchez, Violeta; Kang, Hakmook; Yankeelov, Thomas E.

    2016-01-01

    Purpose Evaluation of [18F]-FMISO-PET imaging as a metric for evaluating early response to trastuzumab therapy with histological validation in a murine model of HER2+ breast cancer. Procedures Mice with BT474, HER2+ tumors, were imaged with [18F]-FMISO-PET during trastuzumab therapy. Pimonidazole staining was used to confirm hypoxia from imaging. Results [18F]-FMISO-PET indicated significant decreases in hypoxia beginning on day 3 (P < 0.01) prior to changes in tumor size. These results were confirmed with pimonidazole staining on day 7 (P < 0.01); additionally, there was a significant positive linear correlation between histology and PET imaging (r2=0.85). Conclusions [18F]-FMISO-PET is a clinically relevant modality which provides the opportunity to 1) predict response to HER2+ therapy before changes in tumor size, and 2) identify decreases hypoxia which has the potential to guide subsequent therapy. PMID:27506906

  5. Implementation and applications of dual-modality imaging

    NASA Astrophysics Data System (ADS)

    Hasegawa, Bruce H.; Barber, William C.; Funk, Tobias; Hwang, Andrew B.; Taylor, Carmen; Sun, Mingshan; Seo, Youngho

    2004-06-01

    In medical diagnosis, functional or physiological data can be acquired using radionuclide imaging with positron emission tomography or with single-photon emission computed tomography. However, anatomical or structural data can be acquired using X-ray computed tomography. In dual-modality imaging, both radionuclide and X-ray detectors are incorporated in an imaging system to allow both functional and structural data to be acquired in a single procedure without removing the patient from the imaging system. In a clinical setting, dual-modality imaging systems commonly are used to localize radiopharmaceutical uptake with respect to the patient's anatomy. This helps the clinician to differentiate disease from regions of normal radiopharmaceutical accumulation, to improve diagnosis or cancer staging, or to facilitate planning for radiation therapy or surgery. While initial applications of dual-modality imaging were developed for clinical imaging on humans, it now is recognized that these systems have potentially important applications for imaging small animals involved in experimental studies including basic investigations of mammalian biology and development of new pharmaceuticals for diagnosis or treatment of disease.

  6. Evaluation of a silicon photomultiplier PET insert for simultaneous PET and MR imaging

    SciTech Connect

    Ko, Guen Bae; Kim, Kyeong Yun; Yoon, Hyun Suk; Son, Jeong-Whan; Lee, Min Sun; Im, Hyung-Jun; Lee, Jae Sung

    2016-01-15

    Purpose: In this study, the authors present a silicon photomultiplier (SiPM)-based positron emission tomography (PET) insert dedicated to small animal imaging with high system performance and robustness to temperature change. Methods: The insert consists of 64 LYSO-SiPM detector blocks arranged in 4 rings of 16 detector blocks to yield a ring diameter of 64 mm and axial field of view of 55 mm. Each detector block consists of a 9 × 9 array of LYSO crystals (1.2 × 1.2 × 10 mm{sup 3}) and a monolithic 4 × 4 SiPM array. The temperature of each monolithic SiPM is monitored, and the proper bias voltage is applied according to the temperature reading in real time to maintain uniform performance. The performance of this PET insert was characterized using National Electrical Manufacturers Association NU 4-2008 standards, and its feasibility was evaluated through in vivo mouse imaging studies. Results: The PET insert had a peak sensitivity of 3.4% and volumetric spatial resolutions of 1.92 (filtered back projection) and 0.53 (ordered subset expectation maximization) mm{sup 3} at center. The peak noise equivalent count rate and scatter fraction were 42.4 kcps at 15.08 MBq and 16.5%, respectively. By applying the real-time bias voltage adjustment, an energy resolution of 14.2% ± 0.3% was maintained and the count rate varied ≤1.2%, despite severe temperature changes (10–30 °C). The mouse imaging studies demonstrate that this PET insert can produce high-quality images useful for imaging studies on the small animals. Conclusions: The developed MR-compatible PET insert is designed for insertion into a narrow-bore magnetic resonance imaging scanner, and it provides excellent imaging performance for PET/MR preclinical studies.

  7. Dual PET and Near-Infrared Fluorescence Imaging Probes as Tools for Imaging in Oncology

    PubMed Central

    An, Fei-Fei; Chan, Mark; Kommidi, Harikrishna; Ting, Richard

    2016-01-01

    OBJECTIVE The purpose of this article is to summarize advances in PET fluorescence resolution, agent design, and preclinical imaging that make a growing case for clinical PET fluorescence imaging. CONCLUSION Existing SPECT, PET, fluorescence, and MRI contrast imaging techniques are already deeply integrated into the management of cancer, from initial diagnosis to the observation and management of metastases. Combined positron-emitting fluorescent contrast agents can convey new or substantial benefits that improve on these proven clinical contrast agents. PMID:27223168

  8. Thresholding in PET images of static and moving targets

    NASA Astrophysics Data System (ADS)

    Yaremko, Brian; Riauka, Terence; Robinson, Don; Murray, Brad; Alexander, Abraham; McEwan, Alexander; Roa, Wilson

    2005-12-01

    Continued therapeutic gain in the treatment of non-small-cell lung cancer (NSCLC) will depend upon our ability to escalate the dose to the primary tumour while minimizing normal tissue toxicity. Both these objectives are facilitated by the accurate definition of a target volume that is as small as possible. To this end, both tumour immobilizations via deep inspiratory breath-hold, along with positron emission tomography (PET), have emerged as two promising approaches. Though PET is an excellent means of defining the general location of a tumour focus, its ability to define exactly the geometric extent of such a focus strongly depends upon selection of an appropriate image threshold. However, in clinical practice, the image threshold is typically not chosen according to consistent, well-established criteria. This study explores the relationship between image threshold and the resultant PET-defined volume using a series of F-18 radiotracer-filled hollow spheres of known internal volumes, both static and under oscillatory motion. The effects of both image threshold and tumour motion on the resultant PET image are examined. Imaging data are further collected from a series of simulated gated PET acquisitions in order to test the feasibility of a patient-controlled gating mechanism during deep inspiratory breath-hold. This study illustrates quantitatively considerable variability in resultant PET-defined tumour volumes depending upon numerous factors, including image threshold, size of the lesion, the presence of tumour motion and the scanning protocol. In this regard, when using PET in treatment planning for NSCLC, the radiation oncologist must select the image threshold very carefully to avoid either under-dosing the tumour or overdosing normal tissues.

  9. Fusion Imaging: A Novel Staging Modality in Testis Cancer

    DTIC Science & Technology

    2010-01-01

    conducted. Patients underwent con- ventional imaging evaluation to include CT abdo - men/pelvis, CXR, as well as a full clinical evaluation to include...positron emission tomography (PET) has been utilized in con- junction with computed tomography ( CT ) and chest radiographs (CXR) to survey patients for...metastatic or recurrent disease. While CT is the standard of care for locating the presence of lymphadenopathy or retro- peritoneal masses, its

  10. Prediction of standard-dose brain PET image by using MRI and low-dose brain [{sup 18}F]FDG PET images

    SciTech Connect

    Kang, Jiayin; Gao, Yaozong; Shi, Feng; Lalush, David S.; Lin, Weili; Shen, Dinggang

    2015-09-15

    Purpose: Positron emission tomography (PET) is a nuclear medical imaging technology that produces 3D images reflecting tissue metabolic activity in human body. PET has been widely used in various clinical applications, such as in diagnosis of brain disorders. High-quality PET images play an essential role in diagnosing brain diseases/disorders. In practice, in order to obtain high-quality PET images, a standard-dose radionuclide (tracer) needs to be used and injected into a living body. As a result, it will inevitably increase the patient’s exposure to radiation. One solution to solve this problem is predicting standard-dose PET images using low-dose PET images. As yet, no previous studies with this approach have been reported. Accordingly, in this paper, the authors propose a regression forest based framework for predicting a standard-dose brain [{sup 18}F]FDG PET image by using a low-dose brain [{sup 18}F]FDG PET image and its corresponding magnetic resonance imaging (MRI) image. Methods: The authors employ a regression forest for predicting the standard-dose brain [{sup 18}F]FDG PET image by low-dose brain [{sup 18}F]FDG PET and MRI images. Specifically, the proposed method consists of two main steps. First, based on the segmented brain tissues (i.e., cerebrospinal fluid, gray matter, and white matter) in the MRI image, the authors extract features for each patch in the brain image from both low-dose PET and MRI images to build tissue-specific models that can be used to initially predict standard-dose brain [{sup 18}F]FDG PET images. Second, an iterative refinement strategy, via estimating the predicted image difference, is used to further improve the prediction accuracy. Results: The authors evaluated their algorithm on a brain dataset, consisting of 11 subjects with MRI, low-dose PET, and standard-dose PET images, using leave-one-out cross-validations. The proposed algorithm gives promising results with well-estimated standard-dose brain [{sup 18}F]FDG PET

  11. Current status of PET imaging of differentiated thyroid cancer with second generation radiopharmaceuticals.

    PubMed

    Lauri, C; Di Traglia, S; Galli, F; Pizzichini, P; Signore, A

    2015-03-01

    Although the prognosis of differentiated thyroid cancer (DTC) is favorable, some histotypes show worst clinical outcome and higher risk of recurrence. Serum thyroglobulin (Tg) levels and 131I-whole-body-scan (WBS), together with neck ultrasound (US), represent the golden standard for DTC follow-up. Nevertheless, the relatively high frequency of patients with high Tg levels and negative WBS requires further investigations by using new imaging modalities. The availability of whole body positron emission tomography (PET) methods, in parallel with the advances in radiochemistry, offer a wide substrate for many solutions. To this day ¹⁸F-fluoro-deoxy-glucose (¹⁸F-FDG) PET/CT still represents the imaging of choice in follow-up of patients with high serum Tg and negative ¹³¹I-WBS but in the last decades the research has focused on finding "second generation" radiopharmaceuticals for PET imaging, with both diagnostic and prognostic purposes, aiming to change the way to image thyroid cancer. Moreover, the use of various PET radiopharmaceuticals, that offer the possibility to explore different pathways involved in thyroid cancer, could find important applications in the near future for clinical decision making in order to program tailored treatments and follow-up. It would be desirable to use the same radiopharmaceutical for both imaging and dosimetric purpose to achieve a tailored therapy. Many efforts are focused in this direction and ¹²⁴I-PET/CT is now emerging as a valid tool in restaging and therapy management of DTC with promising results. Although the preliminary data available in literature require a confirmation in larger studies with longer follow-up, we think that in next future ¹²⁴I-PET/CT could gain an important role for management of DTC. The aim of this review was to perform a systematic analysis of literature describing the state of art of "second generation" PET-radiopharmaceuticals for imaging DTC. Discussion is focused on the utility of ¹²⁴I-PET

  12. [Knee imaging: what is the best modality].

    PubMed

    Tavernier, T; Dejour, D

    2001-03-01

    A wide range of exams are available for imaging the knee: standard radiography, ultrasound, bone scintigraphy, CT scan, arthroscan, MRI, arthro-MRI. The radiologist must be aware of the performance capacities of each technique in order to orient the clinician's choice towards the most appropriate exam in a given clinical situation. In the first part of this paper, we examine the performances, advantages and disadvantages of each technique: exam conditions (patient position, incidence, slice thickness, sequence.) are detailed as required. The second part is a practical guide for some typical clinical situations with decision trees for ordering necessary and sufficient explorations.

  13. Recent developments of imaging modalities of carotid artery stenting.

    PubMed

    Umemoto, Tomoyuki; Pacchioni, Andrea; Nikas, Dimitrios; Reimers, Bernhard

    2017-02-01

    Compared with conventional angiogram-guided procedure, intravascular imaging modalities give us a lot of useful information to make the procedure better. Intravascular imaging modalities give us the information about lesion characters, reference vessel diameter and the interaction between the stent strut and the plaque such as stent strut malapposition or plaque prolapse in real time during the procedure. We can change our strategy according to this information. Intravascular ultrasound (IVUS) is a most common intravascular imaging modality during carotid artery stenting (CAS) in these days. Its advantage is easy to use compared with optical coherence tomograpy (OCT) which has been reported recently in some case reports or case series. However, due to its high resolution, OCT provides more detailed information especially about plaque prolapse and strut malapposition. IVUS and OCT have a potential to improve acute result and reduce the procedural complication by providing the data of lesion character, reference vessel diameter and the interaction of stent strut and vessel wall. Interventionalists who perform CAS procedure should acquire proficiency in imaging modalities during CAS procedure.

  14. Role of imaging modalities in diagnosis and management of pyomyositis

    SciTech Connect

    Yousefzadeh, D.K.; Mulligan, G.M.; Young, C.S.; Schumann, E.M.; Bosworth, D.E.; Pringle, K.C.

    1982-08-01

    A case of tropical pyomyositis in a temperate climate is reported and 29 more cases are reviewed from the literature. Because of its rarity and deceiving clinical presentation, the disorder may go unrecognized for weeks in nontropical regions. The role of various imaging modalities in timely and accurate diagnosis and nonsurgical management of this disorder is discussed.

  15. Tau Positron Emission Tomography (PET) Imaging: Past, Present, and Future.

    PubMed

    Ariza, Manuela; Kolb, Hartmuth C; Moechars, Dieder; Rombouts, Frederik; Andrés, José Ignacio

    2015-06-11

    Alzheimer's disease (AD) is a chronic neurodegenerative disorder and the most common cause of dementia among the elderly population. The good correlation of the density and neocortical spread of neurofibrillary tangles (NFTs) with clinical AD disease progression offers an opportunity for the early diagnosis and staging using a noninvasive imaging technique such as positron emission tomography (PET). Thus, PET imaging of NFTs not only holds promise as a diagnostic tool but also may enable the development of disease modifying therapeutics for AD. In this review, we focus on the structural diversity of tau PET tracers, the challenges related to the identification of high affinity and highly selective NFT ligands, and recent progress in the clinical development of tau PET radioligands.

  16. Optical tomography: Development of a new medical imaging modality

    SciTech Connect

    Hebden, Jeremy C.

    1998-08-28

    The demonstrated success of near-infrared spectroscopy as a diagnostic tool in medicine has encouraged physicists to pursue the development of an imaging technique based on the transmittance of optical wavelengths through tissue. Potential clinical applications include a means of detecting breast disease, and a cerebral imaging modality for mapping oxygenation and haemodynamics in the brain of newborn infants. Imaging of tissues with light is severely restricted by the overwhelming scatter which occurs when optical radiation propagates through tissue. However, recent innovations in technology and the development of new tomographic reconstruction procedures suggest that a clinically viable imaging modality is achievable. In this paper the recent progress in this field of research is reviewed, and the prospects for ultimate success are discussed.

  17. PET/CT (and CT) instrumentation, image reconstruction and data transfer for radiotherapy planning.

    PubMed

    Sattler, Bernhard; Lee, John A; Lonsdale, Markus; Coche, Emmanuel

    2010-09-01

    The positron emission tomography in combination with CT in hybrid, cross-modality imaging systems (PET/CT) gains more and more importance as a part of the treatment-planning procedure in radiotherapy. Positron emission tomography (PET), as a integral part of nuclear medicine imaging and non-invasive imaging technique, offers the visualization and quantification of pre-selected tracer metabolism. In combination with the structural information from CT, this molecular imaging technique has great potential to support and improve the outcome of the treatment-planning procedure prior to radiotherapy. By the choice of the PET-Tracer, a variety of different metabolic processes can be visualized. First and foremost, this is the glucose metabolism of a tissue as well as for instance hypoxia or cell proliferation. This paper comprises the system characteristics of hybrid PET/CT systems. Acquisition and processing protocols are described in general and modifications to cope with the special needs in radiooncology. This starts with the different position of the patient on a special table top, continues with the use of the same fixation material as used for positioning of the patient in radiooncology while simulation and irradiation and leads to special processing protocols that include the delineation of the volumes that are subject to treatment planning and irradiation (PTV, GTV, CTV, etc.). General CT acquisition and processing parameters as well as the use of contrast enhancement of the CT are described. The possible risks and pitfalls the investigator could face during the hybrid-imaging procedure are explained and listed. The interdisciplinary use of different imaging modalities implies a increase of the volume of data created. These data need to be stored and communicated fast, safe and correct. Therefore, the DICOM-Standard provides objects and classes for this purpose (DICOM RT). Furthermore, the standard DICOM objects and classes for nuclear medicine (NM, PT) and

  18. 4D PET iterative deconvolution with spatiotemporal regularization for quantitative dynamic PET imaging.

    PubMed

    Reilhac, Anthonin; Charil, Arnaud; Wimberley, Catriona; Angelis, Georgios; Hamze, Hasar; Callaghan, Paul; Garcia, Marie-Paule; Boisson, Frederic; Ryder, Will; Meikle, Steven R; Gregoire, Marie-Claude

    2015-09-01

    Quantitative measurements in dynamic PET imaging are usually limited by the poor counting statistics particularly in short dynamic frames and by the low spatial resolution of the detection system, resulting in partial volume effects (PVEs). In this work, we present a fast and easy to implement method for the restoration of dynamic PET images that have suffered from both PVE and noise degradation. It is based on a weighted least squares iterative deconvolution approach of the dynamic PET image with spatial and temporal regularization. Using simulated dynamic [(11)C] Raclopride PET data with controlled biological variations in the striata between scans, we showed that the restoration method provides images which exhibit less noise and better contrast between emitting structures than the original images. In addition, the method is able to recover the true time activity curve in the striata region with an error below 3% while it was underestimated by more than 20% without correction. As a result, the method improves the accuracy and reduces the variability of the kinetic parameter estimates calculated from the corrected images. More importantly it increases the accuracy (from less than 66% to more than 95%) of measured biological variations as well as their statistical detectivity.

  19. Compact and mobile high resolution PET brain imager

    DOEpatents

    Majewski, Stanislaw [Yorktown, VA; Proffitt, James [Newport News, VA

    2011-02-08

    A brain imager includes a compact ring-like static PET imager mounted in a helmet-like structure. When attached to a patient's head, the helmet-like brain imager maintains the relative head-to-imager geometry fixed through the whole imaging procedure. The brain imaging helmet contains radiation sensors and minimal front-end electronics. A flexible mechanical suspension/harness system supports the weight of the helmet thereby allowing for patient to have limited movements of the head during imaging scans. The compact ring-like PET imager enables very high resolution imaging of neurological brain functions, cancer, and effects of trauma using a rather simple mobile scanner with limited space needs for use and storage.

  20. Imaging of congenital heart disease in adults: choice of modalities.

    PubMed

    Orwat, Stefan; Diller, Gerhard-Paul; Baumgartner, Helmut

    2014-01-01

    Major advances in noninvasive imaging of adult congenital heart disease have been accomplished. These tools play now a key role in comprehensive diagnostic work-up, decision for intervention, evaluation for the suitability of specific therapeutic options, monitoring of interventions and regular follow-up. Besides echocardiography, magnetic resonance (CMR) and computed tomography (CT) have gained particular importance. The choice of imaging modality has thus become a critical issue. This review summarizes strengths and limitations of the different imaging modalities and how they may be used in a complementary fashion. Echocardiography obviously remains the workhorse of imaging routinely used in all patients. However, in complex disease and after surgery echocardiography alone frequently remains insufficient. CMR is particularly useful in this setting and allows reproducible and accurate quantification of ventricular function and comprehensive assessment of cardiac anatomy, aorta, pulmonary arteries and venous return including complex flow measurements. CT is preferred when CMR is contraindicated, when superior spatial resolution is required or when "metallic" artefacts limit CMR imaging. In conclusion, the use of currently available imaging modalities in adult congenital heart disease needs to be complementary. Echocardiography remains the basis tool, CMR and CT should be added considering specific open questions and the ability to answer them, availability and economic issues.

  1. Development of a triple modality small animal planar imaging system

    SciTech Connect

    A. G. Weisenberger, Z. Lee, S. Majewski, B. Kross, V. Popov, B. Welch, R. Wojcik, C. Zorn

    2006-02-01

    Recently small animal research utilizing nuclear medicine based imaging has been combined with structural anatomical imaging from x-ray radiography providing a powerful tool for animal researchers. The addition of a third modality is the goal of our instrumentation development. Thomas Jefferson National Accelerator Facility and Case Western Reserve University have been collaborating on the development of a planar imaging system which in addition to radiopharmaceutical based functional imaging and x-ray radiography structural imaging also allows for the in vivo bioluminescence imaging thus providing another functional imaging modality. For the gamma camera we use is a Hamamatsu position sensitive photomultiplier tube coupled to a pixellated NaI(TI) scintillator array with individual crystal elements 1 mm × 1 mm × 5 mm in size and a 0.25 mm septum between each element. The gamma camera has a 10 cm diameter active area and can be used for 125I, 99mT and 111In radionuclide imaging. To acquire anatomical information we are using a Rad-Icon Shad-o-Box X-ray detector that provides a field of view of 5 cm × 10 cm. The x-ray source is a Source-Ray compact x-ray generator. We are using a Princeton Instruments cooled CCD based detector for the imaging of the bio-distribution of bioluminescence. All three imaging instruments will be integrated into a single light tight / x-ray tight enclosure.

  2. Model-based image reconstruction for four-dimensional PET

    SciTech Connect

    Li Tianfang; Thorndyke, Brian; Schreibmann, Eduard; Yang Yong; Xing Lei

    2006-05-15

    Positron emission tonography (PET) is useful in diagnosis and radiation treatment planning for a variety of cancers. For patients with cancers in thoracic or upper abdominal region, the respiratory motion produces large distortions in the tumor shape and size, affecting the accuracy in both diagnosis and treatment. Four-dimensional (4D) (gated) PET aims to reduce the motion artifacts and to provide accurate measurement of the tumor volume and the tracer concentration. A major issue in 4D PET is the lack of statistics. Since the collected photons are divided into several frames in the 4D PET scan, the quality of each reconstructed frame degrades as the number of frames increases. The increased noise in each frame heavily degrades the quantitative accuracy of the PET imaging. In this work, we propose a method to enhance the performance of 4D PET by developing a new technique of 4D PET reconstruction with incorporation of an organ motion model derived from 4D-CT images. The method is based on the well-known maximum-likelihood expectation-maximization (ML-EM) algorithm. During the processes of forward- and backward-projection in the ML-EM iterations, all projection data acquired at different phases are combined together to update the emission map with the aid of deformable model, the statistics is therefore greatly improved. The proposed algorithm was first evaluated with computer simulations using a mathematical dynamic phantom. Experiment with a moving physical phantom was then carried out to demonstrate the accuracy of the proposed method and the increase of signal-to-noise ratio over three-dimensional PET. Finally, the 4D PET reconstruction was applied to a patient case.

  3. Intraobserver and Interobserver Variability in GTV Delineation on FDG-PET-CT Images of Head and Neck Cancers

    SciTech Connect

    Breen, Stephen L. |. E-mail: Stephen.Breen@rmp.uhn.on.ca; Publicover, Julia; De Silva, Shiroma; Pond, Greg; Brock, Kristy |; O'Sullivan, Brian |; Cummings, Bernard; Dawson, Laura; Kim, John; Ringash, Jolie; Waldron, John |; Keller, Anne |; Yu, Eugene; Hendler, Aaron |

    2007-07-01

    Purpose: To determine if the addition of fluorodeoxyglucose positron emission tomography (FDG-PET) data changes primary site gross tumor volumes (GTVs) in head and neck cancers. Methods and Materials: Computed tomography (CT), contrast-enhanced CT, and FDG-PET-CT scans were obtained in 10 patients with head and neck cancers. Eight experienced observers (6 head and neck oncologists and 2 neuro-radiologists) with access to clinical and radiologic reports outlined primary site GTVs on each modality. Three cases were recontoured twice to assess intraobserver variability. The magnitudes of the GTVs were compared. Intra- and interobserver variability was assessed by a two-way repeated measures analysis of variance. Inter- and intraobserver reliability were calculated. Results: There were no significant differences in the GTVs across the image modalities when compared as ensemble averages; the Wilcoxon matched-pairs signed-rank test showed that CT volumes were larger than PET-CT. Observers demonstrated the greatest consistency and were most interchangeable on contrast-enhanced CT; they performed less reliably on PET-CT. Conclusions: The addition of PET-CT to primary site GTV delineation of head and neck cancers does not change the volume of the GTV defined by this group of expert observers in this patient sample. An FDG-PET may demonstrate differences in neck node delineation and in other disease sites.

  4. Fusion of PET and MRI for Hybrid Imaging

    NASA Astrophysics Data System (ADS)

    Cho, Zang-Hee; Son, Young-Don; Kim, Young-Bo; Yoo, Seung-Schik

    Recently, the development of the fusion PET-MRI system has been actively studied to meet the increasing demand for integrated molecular and anatomical imaging. MRI can provide detailed anatomical information on the brain, such as the locations of gray and white matter, blood vessels, axonal tracts with high resolution, while PET can measure molecular and genetic information, such as glucose metabolism, neurotransmitter-neuroreceptor binding and affinity, protein-protein interactions, and gene trafficking among biological tissues. State-of-the-art MRI systems, such as the 7.0 T whole-body MRI, now can visualize super-fine structures including neuronal bundles in the pons, fine blood vessels (such as lenticulostriate arteries) without invasive contrast agents, in vivo hippocampal substructures, and substantia nigra with excellent image contrast. High-resolution PET, known as High-Resolution Research Tomograph (HRRT), is a brain-dedicated system capable of imaging minute changes of chemicals, such as neurotransmitters and -receptors, with high spatial resolution and sensitivity. The synergistic power of the two, i.e., ultra high-resolution anatomical information offered by a 7.0 T MRI system combined with the high-sensitivity molecular information offered by HRRT-PET, will significantly elevate the level of our current understanding of the human brain, one of the most delicate, complex, and mysterious biological organs. This chapter introduces MRI, PET, and PET-MRI fusion system, and its algorithms are discussed in detail.

  5. Pixel-feature hybrid fusion for PET/CT images.

    PubMed

    Zhu, Yang-Ming; Nortmann, Charles A

    2011-02-01

    Color blending is a popular display method for functional and anatomic image fusion. The underlay image is typically displayed in grayscale, and the overlay image is displayed in pseudo colors. This pixel-level fusion provides too much information for reviewers to analyze quickly and effectively and clutters the display. To improve the fusion image reviewing speed and reduce the information clutter, a pixel-feature hybrid fusion method is proposed and tested for PET/CT images. Segments of the colormap are selectively masked to have a few discrete colors, and pixels displayed in the masked colors are made transparent. The colormap thus creates a false contouring effect on overlay images and allows the underlay to show through to give contours an anatomic context. The PET standardized uptake value (SUV) is used to control where colormap segments are masked. Examples show that SUV features can be extracted and blended with CT image instantaneously for viewing and diagnosis, and the non-feature part of the PET image is transparent. The proposed pixel-feature hybrid fusion highlights PET SUV features on CT images and reduces display clutters. It is easy to implement and can be used as complementarily to existing pixel-level fusion methods.

  6. Vision 20/20: Magnetic resonance imaging-guided attenuation correction in PET/MRI: Challenges, solutions, and opportunities

    SciTech Connect

    Mehranian, Abolfazl; Arabi, Hossein; Zaidi, Habib

    2016-03-15

    Attenuation correction is an essential component of the long chain of data correction techniques required to achieve the full potential of quantitative positron emission tomography (PET) imaging. The development of combined PET/magnetic resonance imaging (MRI) systems mandated the widespread interest in developing novel strategies for deriving accurate attenuation maps with the aim to improve the quantitative accuracy of these emerging hybrid imaging systems. The attenuation map in PET/MRI should ideally be derived from anatomical MR images; however, MRI intensities reflect proton density and relaxation time properties of biological tissues rather than their electron density and photon attenuation properties. Therefore, in contrast to PET/computed tomography, there is a lack of standardized global mapping between the intensities of MRI signal and linear attenuation coefficients at 511 keV. Moreover, in standard MRI sequences, bones and lung tissues do not produce measurable signals owing to their low proton density and short transverse relaxation times. MR images are also inevitably subject to artifacts that degrade their quality, thus compromising their applicability for the task of attenuation correction in PET/MRI. MRI-guided attenuation correction strategies can be classified in three broad categories: (i) segmentation-based approaches, (ii) atlas-registration and machine learning methods, and (iii) emission/transmission-based approaches. This paper summarizes past and current state-of-the-art developments and latest advances in PET/MRI attenuation correction. The advantages and drawbacks of each approach for addressing the challenges of MR-based attenuation correction are comprehensively described. The opportunities brought by both MRI and PET imaging modalities for deriving accurate attenuation maps and improving PET quantification will be elaborated. Future prospects and potential clinical applications of these techniques and their integration in commercial

  7. Vision 20/20: Magnetic resonance imaging-guided attenuation correction in PET/MRI: Challenges, solutions, and opportunities.

    PubMed

    Mehranian, Abolfazl; Arabi, Hossein; Zaidi, Habib

    2016-03-01

    Attenuation correction is an essential component of the long chain of data correction techniques required to achieve the full potential of quantitative positron emission tomography (PET) imaging. The development of combined PET/magnetic resonance imaging (MRI) systems mandated the widespread interest in developing novel strategies for deriving accurate attenuation maps with the aim to improve the quantitative accuracy of these emerging hybrid imaging systems. The attenuation map in PET/MRI should ideally be derived from anatomical MR images; however, MRI intensities reflect proton density and relaxation time properties of biological tissues rather than their electron density and photon attenuation properties. Therefore, in contrast to PET/computed tomography, there is a lack of standardized global mapping between the intensities of MRI signal and linear attenuation coefficients at 511 keV. Moreover, in standard MRI sequences, bones and lung tissues do not produce measurable signals owing to their low proton density and short transverse relaxation times. MR images are also inevitably subject to artifacts that degrade their quality, thus compromising their applicability for the task of attenuation correction in PET/MRI. MRI-guided attenuation correction strategies can be classified in three broad categories: (i) segmentation-based approaches, (ii) atlas-registration and machine learning methods, and (iii) emission/transmission-based approaches. This paper summarizes past and current state-of-the-art developments and latest advances in PET/MRI attenuation correction. The advantages and drawbacks of each approach for addressing the challenges of MR-based attenuation correction are comprehensively described. The opportunities brought by both MRI and PET imaging modalities for deriving accurate attenuation maps and improving PET quantification will be elaborated. Future prospects and potential clinical applications of these techniques and their integration in commercial

  8. The integration of quantitative multi-modality imaging data into mathematical models of tumors

    NASA Astrophysics Data System (ADS)

    Atuegwu, Nkiruka C.; Gore, John C.; Yankeelov, Thomas E.

    2010-05-01

    Quantitative imaging data obtained from multiple modalities may be integrated into mathematical models of tumor growth and treatment response to achieve additional insights of practical predictive value. We show how this approach can describe the development of tumors that appear realistic in terms of producing proliferating tumor rims and necrotic cores. Two established models (the logistic model with and without the effects of treatment) and one novel model built a priori from available imaging data have been studied. We modify the logistic model to predict the spatial expansion of a tumor driven by tumor cell migration after a voxel's carrying capacity has been reached. Depending on the efficacy of a simulated cytoxic treatment, we show that the tumor may either continue to expand, or contract. The novel model includes hypoxia as a driver of tumor cell movement. The starting conditions for these models are based on imaging data related to the tumor cell number (as estimated from diffusion-weighted MRI), apoptosis (from 99mTc-Annexin-V SPECT), cell proliferation and hypoxia (from PET). We conclude that integrating multi-modality imaging data into mathematical models of tumor growth is a promising combination that can capture the salient features of tumor growth and treatment response and this indicates the direction for additional research.

  9. Characterization of coronary atherosclerosis by intravascular imaging modalities

    PubMed Central

    Honda, Satoshi; Kanaya, Tomoaki; Noguchi, Teruo; Ogawa, Hisao; Yasuda, Satoshi

    2016-01-01

    Coronary artery disease (CAD) is highly prevalent in Western countries and is associated with morbidity, mortality, and a significant economic burden. Despite the development of anti-atherosclerotic medical therapies, many patients still continue to suffer from coronary events. This residual risk indicates the need for better risk stratification and additional therapies to achieve more reductions in cardiovascular risk. Recent advances in imaging modalities have contributed to visualizing atherosclerotic plaques and defining lesion characteristics in vivo. This innovation has been applied to refining revascularization procedure, assessment of anti-atherosclerotic drug efficacy and the detection of high-risk plaques. As such, intravascular imaging plays an important role in further improvement of cardiovascular outcomes in patients with CAD. The current article reviews available intravascular imaging modalities with regard to its method, advantage and disadvantage. PMID:27500094

  10. Combination of pet imaging with viral vectors for identification of cancer metastases.

    PubMed

    Brader, Peter; Wong, Richard J; Horowitz, Gilad; Gil, Ziv

    2012-06-01

    There are three main ways for dissemination of solid tumors: direct invasion, lymphatic spread and hematogenic spread. The presence of metastases is the most significant factor in predicting prognosis and therefore evidence of metastases will influence decision-making regarding treatment. Conventional imaging techniques are limited in the evaluation and localization of metastases due to their restricted ability to identify subcentimeter neoplastic disease. Hence, there is a need for an effective noninvasive modality that can accurately identify occult metastases in cancer patients. One such method is the combination of positron emission tomography (PET) with vectors designed for delivery of reporter genes into target cells. Vectors expressing the herpes simplex virus-1 thymidine kinase (HSV1-tk) reporter system have recently been shown to allow localization of micrometastases in animal models of cancer using non invasive imaging. Combination of HSV1-tk and PET imaging is based on the virtues of vectors which can carry and selectively express the HSV1-tk reporter gene in a variety of cancer cells but not in normal tissue. A radioactive tracer which is applied systemically is phosphorylated by the HSV1-tk enzyme, and as a consequence, the tracer accumulates in proportion to the level of HSV1-tk expression which can be imaged by PET. In this paper we review the recent developments in molecular imaging of micrometastases using replication-competent viral or nonviral vectors carrying the HSV1-tk gene using PET imaging. These diagnostic paradigms introduce an advantageous new concept in noninvasive molecular imaging with the potential benefits for improving patient care by providing guidance for therapy to patients with risk for metastases.

  11. Diagnosing, planning and evaluating osteochondral ankle defects with imaging modalities

    PubMed Central

    van Bergen, Christiaan JA; Gerards, Rogier M; Opdam, Kim TM; Terra, Maaike P; Kerkhoffs, Gino MMJ

    2015-01-01

    This current concepts review outlines the role of different imaging modalities in the diagnosis, preoperative planning, and follow-up of osteochondral ankle defects. An osteochondral ankle defect involves the articular cartilage and subchondral bone (usually of the talus) and is mostly caused by an ankle supination trauma. Conventional radiographs are useful as an initial imaging tool in the diagnostic process, but have only moderate sensitivity for the detection of osteochondral defects. Computed tomography (CT) and magnetic resonance imaging (MRI) are more accurate imaging modalities. Recently, ultrasonography and single photon emission CT have been described for the evaluation of osteochondral talar defects. CT is the most valuable modality for assessing the exact location and size of bony lesions. Cartilage and subchondral bone damage can be visualized using MRI, but the defect size tends to be overestimated due to bone edema. CT with the ankle in full plantar flexion has been shown a reliable tool for preoperative planning of the surgical approach. Postoperative imaging is useful for objective assessment of repair tissue or degenerative changes of the ankle joint. Plain radiography, CT and MRI have been used in outcome studies, and different scoring systems are available. PMID:26716090

  12. Adaptive conductance filtering for spatially varying noise in PET images

    NASA Astrophysics Data System (ADS)

    Padfield, Dirk R.; Manjeshwar, Ravindra

    2006-03-01

    PET images that have been reconstructed with unregularized algorithms are commonly smoothed with linear Gaussian filters to control noise. Since these filters are spatially invariant, they degrade feature contrast in the image, compromising lesion detectability. Edge-preserving smoothing filters can differentially preserve edges and features while smoothing noise. These filters assume spatially uniform noise models. However, the noise in PET images is spatially variant, approximately following a Poisson behavior. Therefore, different regions of a PET image need smoothing by different amounts. In this work, we introduce an adaptive filter, based on anisotropic diffusion, designed specifically to overcome this problem. In this algorithm, the diffusion is varied according to a local estimate of the noise using either the local median or the grayscale image opening to weight the conductance parameter. The algorithm is thus tailored to the task of smoothing PET images, or any image with Poisson-like noise characteristics, by adapting itself to varying noise while preserving significant features in the image. This filter was compared with Gaussian smoothing and a representative anisotropic diffusion method using three quantitative task-relevant metrics calculated on simulated PET images with lesions in the lung and liver. The contrast gain and noise ratio metrics were used to measure the ability to do accurate quantitation; the Channelized Hotelling Observer lesion detectability index was used to quantify lesion detectability. The adaptive filter improved the signal-to-noise ratio by more than 45% and lesion detectability by more than 55% over the Gaussian filter while producing "natural" looking images and consistent image quality across different anatomical regions.

  13. Adrenal masses of varied etiology: anatomical and molecular imaging features on PET-CT.

    PubMed

    Sharma, Punit; Singh, Harmandeep; Dhull, Varun Singh; Suman KC, Sudhir; Kumar, Abhishek; Bal, Chandrasekhar; Kumar, Rakesh

    2014-03-01

    A wide spectrum of benign and malignant diseases can present as an adrenal mass. Combined PET-CT is useful for evaluation of adrenocortical and adrenomedullary masses. F-FDG has been extensively used as PET radiotracer for this purpose. F-FDOPA PET, Ga-DOTA peptide (Ga-DOTANOC/TATE) PET, and C-HED PET have also been used for imaging of adrenal medullary lesions, whereas C-MTO PET has been used for adrenocortical imaging. We provide a review of imaging characteristics of adrenal gland pathologies on PET-CT using different tracers.

  14. Motion correction of PET brain images through deconvolution: II. Practical implementation and algorithm optimization

    NASA Astrophysics Data System (ADS)

    Raghunath, N.; Faber, T. L.; Suryanarayanan, S.; Votaw, J. R.

    2009-02-01

    Image quality is significantly degraded even by small amounts of patient motion in very high-resolution PET scanners. When patient motion is known, deconvolution methods can be used to correct the reconstructed image and reduce motion blur. This paper describes the implementation and optimization of an iterative deconvolution method that uses an ordered subset approach to make it practical and clinically viable. We performed ten separate FDG PET scans using the Hoffman brain phantom and simultaneously measured its motion using the Polaris Vicra tracking system (Northern Digital Inc., Ontario, Canada). The feasibility and effectiveness of the technique was studied by performing scans with different motion and deconvolution parameters. Deconvolution resulted in visually better images and significant improvement as quantified by the Universal Quality Index (UQI) and contrast measures. Finally, the technique was applied to human studies to demonstrate marked improvement. Thus, the deconvolution technique presented here appears promising as a valid alternative to existing motion correction methods for PET. It has the potential for deblurring an image from any modality if the causative motion is known and its effect can be represented in a system matrix.

  15. Optimally stabilized PET image denoising using trilateral filtering.

    PubMed

    Mansoor, Awais; Bagci, Ulas; Mollura, Daniel J

    2014-01-01

    Low-resolution and signal-dependent noise distribution in positron emission tomography (PET) images makes denoising process an inevitable step prior to qualitative and quantitative image analysis tasks. Conventional PET denoising methods either over-smooth small-sized structures due to resolution limitation or make incorrect assumptions about the noise characteristics. Therefore, clinically important quantitative information may be corrupted. To address these challenges, we introduced a novel approach to remove signal-dependent noise in the PET images where the noise distribution was considered as Poisson-Gaussian mixed. Meanwhile, the generalized Anscombe's transformation (GAT) was used to stabilize varying nature of the PET noise. Other than noise stabilization, it is also desirable for the noise removal filter to preserve the boundaries of the structures while smoothing the noisy regions. Indeed, it is important to avoid significant loss of quantitative information such as standard uptake value (SUV)-based metrics as well as metabolic lesion volume. To satisfy all these properties, we extended bilateral filtering method into trilateral filtering through multiscaling and optimal Gaussianization process. The proposed method was tested on more than 50 PET-CT images from various patients having different cancers and achieved the superior performance compared to the widely used denoising techniques in the literature.

  16. PET and NIR optical imaging using self-illuminating (64)Cu-doped chelator-free gold nanoclusters.

    PubMed

    Hu, Hao; Huang, Peng; Weiss, Orit Jacobson; Yan, Xuefeng; Yue, Xuyi; Zhang, Molly Gu; Tang, Yuxia; Nie, Liming; Ma, Ying; Niu, Gang; Wu, Kaichun; Chen, Xiaoyuan

    2014-12-01

    Self-illuminating fluorescence imaging without autofluorescence background interference has recently aroused more research interests in molecular imaging. Currently, only a few self-illuminating probes were developed, based mainly on toxic quantum dots such as CdSe, CdTe. Herein, we report a novel design of nontoxic self-illuminating gold nanocluster ((64)Cu-doped AuNCs) for dual-modality positron emission tomography (PET) and near-infrared (NIR) fluorescence imaging based on Cerenkov resonance energy transfer (CRET). PET radionuclide (64)Cu was introduced by a chelator-free doping method, which played dual roles as the energy donor and the PET imaging source. Meanwhile, AuNCs acted as the energy acceptor for NIR fluorescence imaging. (64)Cu-doped AuNCs exhibited efficient CRET-NIR and PET imaging both in vitro and in vivo. In a U87MG glioblastoma xenograft model, (64)Cu-doped AuNCs showed high tumor uptake (14.9 %ID/g at 18 h) and produced satisfactory tumor self-illuminating NIR images in the absence of external excitation. This self-illuminating nanocluster with non-toxicity and good biocompatibility can be employed as a novel imaging contrast agent for biomedical applications, especially for molecular imaging.

  17. PET and NIR Optical Imaging Using Self-Illuminating 64Cu-Doped Chelator-Free Gold Nanoclusters

    PubMed Central

    Hu, Hao; Huang, Peng; Weiss, Orit Jacobson; Yan, Xuefeng; Yue, Xuyi; Zhang, Molly Gu; Tang, Yuxia; Nie, Liming; Ma, Ying; Niu, Gang; Wu, Kaichun; Chen, Xiaoyuan

    2014-01-01

    Self-illuminating fluorescence imaging without autofluorescence background interference has recently aroused more research interests in molecular imaging. Currently, only a few self-illuminating probes were developed, based mainly on toxic quantum dots such as CdSe, CdTe. Herein, we report a novel design of nontoxic self-illuminating gold nanocluster (64Cu-doped AuNCs) for dual-modality positron emission tomography (PET) and near-infrared (NIR) fluorescence imaging based on Cerenkov resonance energy transfer (CRET). PET radionuclide 64Cu was introduced by a chelator-free doping method, which played dual roles as the energy donor and the PET imaging source. Meanwhile, AuNCs acted as the energy acceptor for NIR fluorescence imaging. 64Cu-doped AuNCs exhibited efficient CRET-NIR and PET imaging both in vitro and in vivo. In a U87MG glioblastoma xenograft model, 64Cu-doped AuNCs showed high tumor uptake (14.9%ID/g at 18 h) and produced satisfactory tumor self-illuminating NIR images in the absence of external excitation. This self-illuminating nanocluster with non-toxicity and good biocompatibility can be employed as a novel imaging contrast agent for biomedical applications, especially for molecular imaging. PMID:25224367

  18. Imaging Breast Density: Established and Emerging Modalities1

    PubMed Central

    Chen, Jeon-Hor; Gulsen, Gultekin; Su, Min-Ying

    2015-01-01

    Mammographic density has been proven as an independent risk factor for breast cancer. Women with dense breast tissue visible on a mammogram have a much higher cancer risk than women with little density. A great research effort has been devoted to incorporate breast density into risk prediction models to better estimate each individual’s cancer risk. In recent years, the passage of breast density notification legislation in many states in USA requires that every mammography report should provide information regarding the patient’s breast density. Accurate definition and measurement of breast density are thus important, which may allow all the potential clinical applications of breast density to be implemented. Because the two-dimensional mammography-based measurement is subject to tissue overlapping and thus not able to provide volumetric information, there is an urgent need to develop reliable quantitative measurements of breast density. Various new imaging technologies are being developed. Among these new modalities, volumetric mammographic density methods and three-dimensional magnetic resonance imaging are the most well studied. Besides, emerging modalities, including different x-ray–based, optical imaging, and ultrasound-based methods, have also been investigated. All these modalities may either overcome some fundamental problems related to mammographic density or provide additional density and/or compositional information. The present review article aimed to summarize the current established and emerging imaging techniques for the measurement of breast density and the evidence of the clinical use of these density methods from the literature. PMID:26692524

  19. Precision Medicine in Multiple Sclerosis: Future of PET Imaging of Inflammation and Reactive Astrocytes

    PubMed Central

    Poutiainen, Pekka; Jaronen, Merja; Quintana, Francisco J.; Brownell, Anna-Liisa

    2016-01-01

    Non-invasive molecular imaging techniques can enhance diagnosis to achieve successful treatment, as well as reveal underlying pathogenic mechanisms in disorders such as multiple sclerosis (MS). The cooperation of advanced multimodal imaging techniques and increased knowledge of the MS disease mechanism allows both monitoring of neuronal network and therapeutic outcome as well as the tools to discover novel therapeutic targets. Diverse imaging modalities provide reliable diagnostic and prognostic platforms to better achieve precision medicine. Traditionally, magnetic resonance imaging (MRI) has been considered the golden standard in MS research and diagnosis. However, positron emission tomography (PET) imaging can provide functional information of molecular biology in detail even prior to anatomic changes, allowing close follow up of disease progression and treatment response. The recent findings support three major neuroinflammation components in MS: astrogliosis, cytokine elevation, and significant changes in specific proteins, which offer a great variety of specific targets for imaging purposes. Regardless of the fact that imaging of astrocyte function is still a young field and in need for development of suitable imaging ligands, recent studies have shown that inflammation and astrocyte activation are related to progression of MS. MS is a complex disease, which requires understanding of disease mechanisms for successful treatment. PET is a precise non-invasive imaging method for biochemical functions and has potential to enhance early and accurate diagnosis for precision therapy of MS. In this review we focus on modulation of different receptor systems and inflammatory aspect of MS, especially on activation of glial cells, and summarize the recent findings of PET imaging in MS and present the most potent targets for new biomarkers with the main focus on experimental MS research. PMID:27695400

  20. Image and Dose Simulation in Support of New Mammography Modalities

    SciTech Connect

    Kuruvilla Verghese

    2002-04-05

    This report summarizes the highlights of the research performed under the 2-year NEER grant from the Department of Energy. The primary outcome of the work was a new Monte Carlo code, MCMIS-DS, for Monte Carlo for Mammography Image Simulation including Differential Sampling. The code was written to generate simulated images and dose distributions from two different new digital x-ray imaging modalities, namely, synchrotron imaging (SI) and a slot geometry digital mammography system called Fisher Senoscan. A differential sampling scheme was added to the code to generate multiple images that included variations in the parameters of the measurement system and the object in a single execution of the code. The code is to serve multiple purposes; (1) to answer questions regarding the contribution of scattered photons to images, (2) for use in design optimization studies, and (3) to do up to second-order perturbation studies to assess the effects of design parameter variations and/or physical parameters of the object (the breast) without having to re-run the code for each set of varied parameters. The accuracy and fidelity of the code were validated by a large variety of benchmark studies using published data and also using experimental results from mammography phantoms on both imaging modalities.

  1. Differential diagnosis of adrenal mass using imaging modality: special emphasis on f-18 fluoro-2-deoxy-d-glucose positron emission tomography/computed tomography.

    PubMed

    Lee, Hong Je; Lee, Jaetae

    2014-03-01

    Adrenal incidentalomas are adrenal masses serendipitously detected during an imaging study performed for reasons unrelated to suspicion of adrenal disease. The incidence of adrenal incidentalomas has increased because of the widespread use of various imaging modalities. In oncology patients with adrenal incidentalomas, the characterization of the adrenal masses is challenging because nearly 50% of incidental adrenal masses are metastatic lesions that need special medical attention. Although unenhanced computed tomography (CT) densitometry, chemical shift magnetic resonance imaging (MRI), delayed contrast-enhanced CT and CT histogram analysis have been used as sensitive and specific modalities for differentiating benign from malignant adrenal masses, F-18 fluoro-2-deoxy-D-glucose positron emission tomography (F-18 FDG PET)/CT is a highly accurate imaging modality compared to CT or MRI, especially when these two imaging modalities are combined. In addition, a semiquantitative analysis using standardized uptake value ratio further improves the diagnostic accuracy of F-18 FDG PET/CT in differentiating benign from malignant adrenal masses. Thus, F-18 FDG PET/CT is very helpful for determining the best therapeutic management, especially for assessing the need for surgery.

  2. Current Imaging Modalities for assessing Ocular Blood Flow in Glaucoma

    PubMed Central

    Mohindroo, Chirayu; Kumar, Suresh

    2016-01-01

    Glaucoma may be caused by an interplay of elevated intraocular pressure (IOP), vascular, genetic, anatomical, brain, and immune factors. The direct assessment of ocular hemodynam-ics offers promise for glaucoma detection, differentiation, and possibly new treatment modalities. All the methods currently in use to measure ocular blood flow have inherent limitations and measure different aspects of ocular blood flow. This review article attempts to provide detailed information on ocular perfu-sion pressure as well as an overview of the newly developed imaging technologies used to investigate ocular blood flow in glaucoma patients. How to cite this article Mohindroo C, Ichhpujani P, Kumar S. Current Imaging Modalities for assessing Ocular Blood Flow in Glaucoma. J Curr Glaucoma Pract 2016;10(3):104-112. PMID:27857490

  3. Influence of Iterative Reconstruction Algorithms on PET Image Resolution

    NASA Astrophysics Data System (ADS)

    Karpetas, G. E.; Michail, C. M.; Fountos, G. P.; Valais, I. G.; Nikolopoulos, D.; Kandarakis, I. S.; Panayiotakis, G. S.

    2015-09-01

    The aim of the present study was to assess image quality of PET scanners through a thin layer chromatography (TLC) plane source. The source was simulated using a previously validated Monte Carlo model. The model was developed by using the GATE MC package and reconstructed images obtained with the STIR software for tomographic image reconstruction. The simulated PET scanner was the GE DiscoveryST. A plane source consisted of a TLC plate, was simulated by a layer of silica gel on aluminum (Al) foil substrates, immersed in 18F-FDG bath solution (1MBq). Image quality was assessed in terms of the modulation transfer function (MTF). MTF curves were estimated from transverse reconstructed images of the plane source. Images were reconstructed by the maximum likelihood estimation (MLE)-OSMAPOSL, the ordered subsets separable paraboloidal surrogate (OSSPS), the median root prior (MRP) and OSMAPOSL with quadratic prior, algorithms. OSMAPOSL reconstruction was assessed by using fixed subsets and various iterations, as well as by using various beta (hyper) parameter values. MTF values were found to increase with increasing iterations. MTF also improves by using lower beta values. The simulated PET evaluation method, based on the TLC plane source, can be useful in the resolution assessment of PET scanners.

  4. Differential Receptor Tyrosine Kinase PET Imaging for Therapeutic Guidance

    PubMed Central

    Wehrenberg-Klee, Eric; Turker, N. Selcan; Heidari, Pedram; Larimer, Benjamin; Juric, Dejan; Baselga, José; Scaltriti, Maurizio

    2016-01-01

    Inhibitors of the phosphatidylinositol 3-kinase/protein kinase B/mammalian target of rapamycin (PI3K/AKT/mTOR) pathway hold promise for the treatment of breast cancer, but resistance to these treatments can arise via feedback loops that increase surface expression of the receptor tyrosine kinases (RTK) epidermal growth factor receptor 1 (EGFR) and human epidermal growth factor receptor 3 (HER3), leading to persistent growth pathway signaling. We developed PET probes that provide a method of imaging this response in vivo, determining which tumors may use this escape pathway while avoiding the need for repeated biopsies. Methods: Anti-EGFR-F(ab′)2 and anti-HER3-F(ab′)2 were generated from monoclonal antibodies by enzymatic digestion, conjugated to DOTA, and labeled with 64Cu. A panel of breast cancer cell lines was treated with increasing concentrations of the AKT inhibitor GDC-0068 or the PI3K inhibitor GDC-0941. Pre- and posttreatment expression of EGFR and HER3 was compared using Western blot and correlated to probe accumulation with binding studies. Nude mice xenografts of HCC-70 or MDA-MB-468 were treated with either AKT inhibitor or PI3K inhibitor and imaged with either EGFR or HER3 PET probe. Results: Changes in HER3 and EGFR PET probe accumulation correlate to RTK expression change as assessed by Western blot (R2 of 0.85–0.98). EGFR PET probe PET/CT imaging of HCC70 tumors shows an SUV of 0.32 ± 0.03 for vehicle-, 0.50 ± 0.01 for GDC-0941–, and 0.62 ± 0.01 for GDC-0068–treated tumors, respectively (P < 0.01 for both comparisons to vehicle). HER3 PET probe PET/CT imaging of MDAMB468 tumors shows an SUV of 0.35 ± 0.02 for vehicle- and 0.73 ± 0.05 for GDC-0068–treated tumors (P < 0.01). Conclusion: Our imaging studies, using PET probes specific to EGFR and HER3, show that changes in RTK expression indicative of resistance to PI3K and AKT inhibitors can be seen within days of therapy initiation and are of sufficient magnitude as to allow reliable

  5. Radiological Evaluation of Ambiguous Genitalia with Various Imaging Modalities

    NASA Astrophysics Data System (ADS)

    Ravi, N.; Bindushree, Kadakola

    2012-07-01

    Disorders of sex development (DSDs) are congenital conditions in which the development of chromosomal, gonadal, or anatomic sex is atypical. These can be classified broadly into four categories on the basis of gonadal histologic features: female pseudohermaphroditism (46,XX with two ovaries); male pseudohermaphroditism (46,XY with two testes); true hermaphroditism (ovotesticular DSD) (both ovarian and testicular tissues); and gonadal dysgenesis, either mixed (a testis and a streak gonad) or pure (bilateral streak gonads). Imaging plays an important role in demonstrating the anatomy and associated anomalies. Ultrasonography is the primary modality for demonstrating internal organs and magnetic resonance imaging is used as an adjunct modality to assess for internal gonads and genitalia. Early and appropriate gender assignment is necessary for healthy physical and psychologic development of children with ambiguous genitalia. Gender assignment can be facilitated with a team approach that involves a pediatric endocrinologist, geneticist, urologist, psychiatrist, social worker, neonatologist, nurse, and radiologist, allowing timely diagnosis and proper management. We describe case series on ambiguous genitalia presented to our department who were evaluated with multiple imaging modalities.

  6. HIGH-CONTRAST IMAGING VIA MODAL CONVERGENCE OF DEFORMABLE MIRROR

    SciTech Connect

    Wang Feiling

    2012-06-01

    For extremely high contrast imaging, such as direct observation of faint stellar companions, an adaptive optics system is required to produce low-halo and low-speckle regions in the focal plane. A method for deformable mirror control is proposed to achieve this goal. The method relies on a modal convergence of the deformable mirror driven by a focal-plane metric. The modal sets are derived from the Walsh functions. The Walsh-function modes serve two purposes: the expansion of the actuator displacements and the expansion of the phase functions. Taking advantage of the unique properties of the modal functions, a universal control algorithm is devised for the realization of high-contrast focal planes with and without the help of conventional coronagraphy. Numerical modeling is conducted to simulate complete imaging systems under various scenarios. It is shown that the proposed method reliably produces high-contrast focal planes using either a segmented or a membrane mirror. In the presence of random aberration the method is shown to be able to maintain high-contrast focal planes. Requiring neither retrieval of electric fields nor detailed knowledge of the deformable mirrors, this technique may allow high-contrast imaging in real time.

  7. Molecular PET imaging for biology-guided adaptive radiotherapy of head and neck cancer.

    PubMed

    Hoeben, Bianca A W; Bussink, Johan; Troost, Esther G C; Oyen, Wim J G; Kaanders, Johannes H A M

    2013-10-01

    Integration of molecular imaging PET techniques into therapy selection strategies and radiation treatment planning for head and neck squamous cell carcinoma (HNSCC) can serve several purposes. First, pre-treatment assessments can steer decisions about radiotherapy modifications or combinations with other modalities. Second, biology-based objective functions can be introduced to the radiation treatment planning process by co-registration of molecular imaging with planning computed tomography (CT) scans. Thus, customized heterogeneous dose distributions can be generated with escalated doses to tumor areas where radiotherapy resistance mechanisms are most prevalent. Third, monitoring of temporal and spatial variations in these radiotherapy resistance mechanisms early during the course of treatment can discriminate responders from non-responders. With such information available shortly after the start of treatment, modifications can be implemented or the radiation treatment plan can be adapted tailing the biological response pattern. Currently, these strategies are in various phases of clinical testing, mostly in single-center studies. Further validation in multicenter set-up is needed. Ultimately, this should result in availability for routine clinical practice requiring stable production and accessibility of tracers, reproducibility and standardization of imaging and analysis methods, as well as general availability of knowledge and expertise. Small studies employing adaptive radiotherapy based on functional dynamics and early response mechanisms demonstrate promising results. In this context, we focus this review on the widely used PET tracer (18)F-FDG and PET tracers depicting hypoxia and proliferation; two well-known radiation resistance mechanisms.

  8. Pulmonary imaging using respiratory motion compensated simultaneous PET/MR

    PubMed Central

    Dutta, Joyita; Huang, Chuan; Li, Quanzheng; El Fakhri, Georges

    2015-01-01

    Purpose: Pulmonary positron emission tomography (PET) imaging is confounded by blurring artifacts caused by respiratory motion. These artifacts degrade both image quality and quantitative accuracy. In this paper, the authors present a complete data acquisition and processing framework for respiratory motion compensated image reconstruction (MCIR) using simultaneous whole body PET/magnetic resonance (MR) and validate it through simulation and clinical patient studies. Methods: The authors have developed an MCIR framework based on maximum a posteriori or MAP estimation. For fast acquisition of high quality 4D MR images, the authors developed a novel Golden-angle RAdial Navigated Gradient Echo (GRANGE) pulse sequence and used it in conjunction with sparsity-enforcing k-t FOCUSS reconstruction. The authors use a 1D slice-projection navigator signal encapsulated within this pulse sequence along with a histogram-based gate assignment technique to retrospectively sort the MR and PET data into individual gates. The authors compute deformation fields for each gate via nonrigid registration. The deformation fields are incorporated into the PET data model as well as utilized for generating dynamic attenuation maps. The framework was validated using simulation studies on the 4D XCAT phantom and three clinical patient studies that were performed on the Biograph mMR, a simultaneous whole body PET/MR scanner. Results: The authors compared MCIR (MC) results with ungated (UG) and one-gate (OG) reconstruction results. The XCAT study revealed contrast-to-noise ratio (CNR) improvements for MC relative to UG in the range of 21%–107% for 14 mm diameter lung lesions and 39%–120% for 10 mm diameter lung lesions. A strategy for regularization parameter selection was proposed, validated using XCAT simulations, and applied to the clinical studies. The authors’ results show that the MC image yields 19%–190% increase in the CNR of high-intensity features of interest affected by

  9. The left bundle branch block revised with novel imaging modalities

    PubMed Central

    van Dijk, J.; Mannaerts, H.F.J.; Germans, T.; Hauer, H.A.; Knaapen, P.; Visser, C.A.; Kamp, O.

    2006-01-01

    Left bundle branch block (LBBB) is related to abnormal cardiac conduction and mechanical asynchrony and is associated with hypertension and coronary artery disease. Improved evaluation of left ventricular (LV) mechanical asynchrony is needed, because of the increasing number of patients with LBBB and heart failure. In this paper, we describe tissue Doppler imaging (TDI), strain (rate) imaging and tissue tracking in LBBB patients. A variety of patterns of mechanical activation can be observed in LBBB patients. A recent development, referred to as tissue synchronisation imaging, colour codes TDI time-to-peak systolic velocities of segments and displays mechanical asynchrony. Furthermore, real-time 3D echocardiography provides new regional information about mechanical asynchrony. Contained in an LV model and projected on a bull's eye plot, this modality helps to display the spatial distribution of mechanical asynchrony. Finally, segmental time-to-peak circumferential strain curves, produced by cardiac magnetic resonance imaging, provide additional quantification of LV mechanical asynchrony. Effects of LBBB on regional and global cardiac function are impressive, myocardial involvement seems to play a role and with the help of these novel imaging modalities, new insights continue to develop. ImagesFigure 1Figure 2Figure 3Figure 4Figure 5Figure 6Figure 7 PMID:25696572

  10. Localized Prostate Cancer Detection with 18F FACBC PET/CT: Comparison with MR Imaging and Histopathologic Analysis

    PubMed Central

    Mena, Esther; Shih, Joanna; Pinto, Peter A.; Merino, Maria J.; Lindenberg, Maria L.; Bernardo, Marcelino; McKinney, Yolanda L.; Adler, Stephen; Owenius, Rikard; Choyke, Peter L.; Kurdziel, Karen A.

    2014-01-01

    Purpose To characterize uptake of 1-amino-3-fluorine 18-fluorocyclobutane-1-carboxylic acid (18F FACBC) in patients with localized prostate cancer, benign prostatic hyperplasia (BPH), and normal prostate tissue and to evaluate its potential utility in delineation of intraprostatic cancers in histopathologically confirmed localized prostate cancer in comparison with magnetic resonance (MR) imaging. Materials and Methods Institutional review board approval and written informed consent were obtained for this HIPAA-compliant prospective study. Twenty-one men underwent dynamic and static abdominopelvic 18F FACBC combined positron emission tomography (PET) and computed tomography (CT) and multiparametric (MP) 3-T endorectal MR imaging before robotic-assisted prostatectomy. PET/CT and MR images were coregistered by using pelvic bones as fiducial markers; this was followed by manual adjustments. Whole-mount histopathologic specimens were sliced with an MR-based patient-specific mold. 18F FACBC PET standardized uptake values (SUVs) were compared with those at MR imaging and histopathologic analysis for lesion- and sector-based (20 sectors per patient) analysis. Positive and negative predictive values for each modality were estimated by using generalized estimating equations with logit link function and working independence correlation structure. Results 18F FACBC tumor uptake was rapid but reversible. It peaked 3.6 minutes after injection and reached a relative plateau at 15–20 minutes (SUVmax[15–20min]). Mean prostate tumor SUVmax(15–20min) was significantly higher than that of the normal prostate (4.5 ± 0.5 vs 2.7 ± 0.5) (P < .001); however, it was not significantly different from that of BPH (4.3 ± 0.6) (P = .27). Sector-based comparison with histopathologic analysis, including all tumors, revealed sensitivity and specificity of 67% and 66%, respectively, for 18F FACBC PET/CT and 73% and 79%, respectively, for T2-weighted MR imaging. 18F FACBC PET/CT and MP MR

  11. A dual-modal retinal imaging system with adaptive optics

    PubMed Central

    Meadway, Alexander; Girkin, Christopher A.; Zhang, Yuhua

    2013-01-01

    An adaptive optics scanning laser ophthalmoscope (AO-SLO) is adapted to provide optical coherence tomography (OCT) imaging. The AO-SLO function is unchanged. The system uses the same light source, scanning optics, and adaptive optics in both imaging modes. The result is a dual-modal system that can acquire retinal images in both en face and cross-section planes at the single cell level. A new spectral shaping method is developed to reduce the large sidelobes in the coherence profile of the OCT imaging when a non-ideal source is used with a minimal introduction of noise. The technique uses a combination of two existing digital techniques. The thickness and position of the traditionally named inner segment/outer segment junction are measured from individual photoreceptors. In-vivo images of healthy and diseased human retinas are demonstrated. PMID:24514529

  12. MRI and PET image fusion using fuzzy logic and image local features.

    PubMed

    Javed, Umer; Riaz, Muhammad Mohsin; Ghafoor, Abdul; Ali, Syed Sohaib; Cheema, Tanveer Ahmed

    2014-01-01

    An image fusion technique for magnetic resonance imaging (MRI) and positron emission tomography (PET) using local features and fuzzy logic is presented. The aim of proposed technique is to maximally combine useful information present in MRI and PET images. Image local features are extracted and combined with fuzzy logic to compute weights for each pixel. Simulation results show that the proposed scheme produces significantly better results compared to state-of-art schemes.

  13. Contemporary Diagnostic Imaging Modalities for the Staging and Surveillance of Melanoma Patients: a Meta-analysis

    PubMed Central

    Xing, Yan; Bronstein, Yulia; Ross, Merrick I.; Askew, Robert L.; Lee, Jeffrey E.; Gershenwald, Jeffrey E.; Royal, Richard

    2011-01-01

    Background Meta-analyses were performed to examine the utility of ultrasonography, computed tomography (CT), positron emission tomography (PET), and a combination of both (PET-CT) for the staging and surveillance of melanoma patients. Method Patient-level data from 74 studies containing 10 528 patients (between January 1, 1990, and June, 30, 2009) were used to derive characteristics of the diagnostic tests used. Meta-analyses were conducted by use of Bayesian bivariate binomial models to estimate sensitivity and specificity. Diagnostic odds ratios [ie, true-positive results/false-negative results)/(false-positive results/true-negative results)] and their 95% credible intervals (CrIs) and positive predictive values were used as indicators of test performance. Results Among the four imaging methods examined for the staging of regional lymph nodes, ultrasonography had the highest sensitivity (60%, 95% CrI = 33% to 83%), specificity (97%, 95% CrI = 88% to 99%), and diagnostic odds ratio (42, 95% CrI = 8.08 to 249.8). For staging of distant metastases, PET-CT had the highest sensitivity (80%, 95% CrI = 53% to 93%), specificity (87%, 95% CrI = 54% to 97%), and diagnostic odds ratio (25, 95% CrI = 3.58 to 198.7). Similar trends were observed for melanoma surveillance of lymph node involvement, with ultrasonography having the highest sensitivity (96%, 95% CrI = 85% to 99%), specificity (99%, 95% CrI = 95% to 100%), and diagnostic odds ratio (1675, 95% CrI = 226.6 to 15,920). For distant metastases, PET-CT had the highest sensitivity (86%, 95% CrI = 76% to 93%), specificity (91%, 95% CrI = 79% to 97%), and diagnostic odds ratio (67, 95% CrI = 20.42 to 229.7). Positive predictive values were likewise highest for ultrasonography in lymph node staging and for PET-CT in detecting distant metastases. Conclusion Among the compared modalities, ultrasonography was superior for detecting lymph node metastases, and PET-CT was superior for the detection of distant metastases in both

  14. PET image reconstruction: a robust state space approach.

    PubMed

    Liu, Huafeng; Tian, Yi; Shi, Pengcheng

    2005-01-01

    Statistical iterative reconstruction algorithms have shown improved image quality over conventional nonstatistical methods in PET by using accurate system response models and measurement noise models. Strictly speaking, however, PET measurements, pre-corrected for accidental coincidences, are neither Poisson nor Gaussian distributed and thus do not meet basic assumptions of these algorithms. In addition, the difficulty in determining the proper system response model also greatly affects the quality of the reconstructed images. In this paper, we explore the usage of state space principles for the estimation of activity map in tomographic PET imaging. The proposed strategy formulates the organ activity distribution through tracer kinetics models, and the photon-counting measurements through observation equations, thus makes it possible to unify the dynamic reconstruction problem and static reconstruction problem into a general framework. Further, it coherently treats the uncertainties of the statistical model of the imaging system and the noisy nature of measurement data. Since H(infinity) filter seeks minimummaximum-error estimates without any assumptions on the system and data noise statistics, it is particular suited for PET image reconstruction where the statistical properties of measurement data and the system model are very complicated. The performance of the proposed framework is evaluated using Shepp-Logan simulated phantom data and real phantom data with favorable results.

  15. Impact of FDG-PET/CT Imaging on Nodal Staging for Head-And-Neck Squamous Cell Carcinoma

    SciTech Connect

    Murakami, Ryuji . E-mail: murakami@kaiju.medic.kumamoto-u.ac.jp; Uozumi, Hideaki; Hirai, Toshinori; Nishimura, Ryuichi; Shiraishi, Shinya; Ota, Kazutoshi D.D.S.; Murakami, Daizo; Tomiguchi, Seiji; Oya, Natsuo; Katsuragawa, Shigehiko; Yamashita, Yasuyuki

    2007-06-01

    Purpose: To evaluate the impact of 18F-fluorodeoxyglucose positron emission tomography/computed tomography (FDG-PET/CT) imaging on nodal staging for head-and-neck squamous cell carcinoma (SCC). Methods and Materials: The study population consisted of 23 patients with head-and-neck SCC who were evaluated with FDG-PET/CT and went on to neck dissection. Two observers consensually determined the lesion size and maximum standardized uptake value (SUV{sub max}) and compared the results with pathologic findings on nodal-level involvement. Two different observers (A and B) independently performed three protocols for clinical nodal staging. Methods 1, 2, and 3 were based on conventional modalities, additional visual information from FDG-PET/CT images, and FDG-PET/CT imaging alone with SUV data, respectively. Results: All primary tumors were visualized with FDG-PET/CT. Pathologically, 19 positive and 93 negative nodal levels were identified. The SUV{sub max} overlapped in negative and positive nodes <15 mm in diameter. According to receiver operating characteristics analysis, the size-based SUV{sub max} cutoff values were 1.9, 2.5, and 3.0 for lymph nodes <10 mm, 10-15 mm, and >15 mm, respectively. These cutoff values yielded 79% sensitivity and 99% specificity for nodal-level staging. For Observer A, the sensitivity and specificity in Methods 1, 2, and 3 were 68% and 94%, 68% and 99%, and 84% and 99%, respectively, and Method 3 yielded significantly higher accuracy than Method 1 (p = 0.0269). For Observer B, Method 3 yielded the highest sensitivity (84%) and specificity (99%); however, the difference among the three protocols was not statistically significant. Conclusion: Imaging with FDG-PET/CT with size-based SUV{sub max} cutoff values is an important modality for radiation therapy planning.

  16. Multi-Modality Phantom Development

    SciTech Connect

    Huber, Jennifer S.; Peng, Qiyu; Moses, William W.

    2009-03-20

    Multi-modality imaging has an increasing role in the diagnosis and treatment of a large number of diseases, particularly if both functional and anatomical information are acquired and accurately co-registered. Hence, there is a resulting need for multi modality phantoms in order to validate image co-registration and calibrate the imaging systems. We present our PET-ultrasound phantom development, including PET and ultrasound images of a simple prostate phantom. We use agar and gelatin mixed with a radioactive solution. We also present our development of custom multi-modality phantoms that are compatible with PET, transrectal ultrasound (TRUS), MRI and CT imaging. We describe both our selection of tissue mimicking materials and phantom construction procedures. These custom PET-TRUS-CT-MRI prostate phantoms use agargelatin radioactive mixtures with additional contrast agents and preservatives. We show multi-modality images of these custom prostate phantoms, as well as discuss phantom construction alternatives. Although we are currently focused on prostate imaging, this phantom development is applicable to many multi-modality imaging applications.

  17. SU-E-QI-20: A Review of Advanced PET and CT Image Features for the Evaluation of Tumor Response

    SciTech Connect

    Lu, W

    2014-06-15

    Purpose: To review the literature in using quantitative PET and CT image features for the evaluation of tumor response. Methods: We reviewed and summarized more than fifty papers that use advanced, quantitative PET/CT image features for the evaluation of tumor response. We also discussed future works on extracting disease-specific features, combining multiple and complementary features in response modeling, delineating tumor in multimodality images, and exploring biological explanations of these advanced features. Results: Advanced PET image features considering spatial information, such as tumor volume, tumor shape, total glycolytic volume, histogram distance, and texture features (characterizing spatial distribution of FDG uptake) have been found more informative than the traditional SUVmax for the prediction of tumor response. Advanced CT features, including volumetric, attenuation, morphologic, structure, and texture descriptors, have also been found advantage over the traditional RECIST and WHO criteria in certain tumor types. Conclusions: Advanced, quantitative FDG PET/CT image features have been shown promising for the evaluation of tumor response. With the emerging multi-modality imaging performed at multiple time points for each patient, it becomes more important to analyze the serial images quantitatively, select and combine both complementary and contradictory information from various sources, for accurate and personalized evaluation of tumor response to therapy.

  18. Development of single-channel stereoscopic video imaging modality for real-time retinal imaging

    NASA Astrophysics Data System (ADS)

    Radfar, Edalat; Park, Jihoon; Lee, Sangyeob; Ha, Myungjin; Yu, Sungkon; Jang, Seulki; Jung, Byungjo

    2016-03-01

    Stereoscopic retinal image can effectively help doctors. Most of stereo imaging surgical microscopes are based on dual optical channels and benefit from dual cameras in which left and right cameras capture corresponding left and right eye views. This study developed a single-channel stereoscopic retinal imaging modality based on a transparent rotating deflector (TRD). Two different viewing angles are generated by imaging through the TRD which is mounted on a motor synchronized with a camera and is placed in single optical channel. Because of the function of objective lens in the imaging modality which generate stereo-image from an object at its focal point, and according to eye structure, the optical set up of the imaging modality can compatible for retinal imaging when the cornea and eye lens are engaged in objective lens.

  19. Inert fluorinated gas MRI: a new pulmonary imaging modality.

    PubMed

    Couch, Marcus J; Ball, Iain K; Li, Tao; Fox, Matthew S; Ouriadov, Alexei V; Biman, Birubi; Albert, Mitchell S

    2014-12-01

    Fluorine-19 ((19)F) MRI of the lungs using inhaled inert fluorinated gases can potentially provide high quality images of the lungs that are similar in quality to those from hyperpolarized (HP) noble gas MRI. Inert fluorinated gases have the advantages of being nontoxic, abundant, and inexpensive compared with HP gases. Due to the high gyromagnetic ratio of (19)F, there is sufficient thermally polarized signal for imaging, and averaging within a single breath-hold is possible due to short longitudinal relaxation times. Therefore, the gases do not need to be hyperpolarized prior to their use in MRI. This eliminates the need for an expensive polarizer and expensive isotopes. Inert fluorinated gas MRI of the lungs has been previously demonstrated in animals, and more recently in healthy volunteers and patients with lung diseases. The ongoing improvements in image quality demonstrate the potential of (19)F MRI for visualizing the distribution of ventilation in human lungs and detecting functional biomarkers. In this brief review, the development of inert fluorinated gas MRI, current progress, and future prospects are discussed. The current state of HP noble gas MRI is also briefly discussed in order to provide context to the development of this new imaging modality. Overall, this may be a viable clinical imaging modality that can provide useful information for the diagnosis and management of chronic respiratory diseases.

  20. Conspicuity of Malignant Lesions on PET/CT and Simultaneous Time-Of-Flight PET/MRI

    PubMed Central

    Minamimoto, Ryogo; Iagaru, Andrei; Jamali, Mehran; Holley, Dawn; Barkhodari, Amir; Vasanawala, Shreyas; Zaharchuk, Greg

    2017-01-01

    Purpose To compare the conspicuity of malignant lesions between FDG PET/CT and a new simultaneous, time-of-flight (TOF) enabled PET/MRI scanner. Methods All patients underwent a single-injection of FDG, followed by a dual imaging protocol consisting of PET/CT followed by TOF PET/MRI. PET/CT and PET/MRI images were evaluated by two readers independently for areas of FDG uptake compatible with malignancy, and then categorized into 5 groups (1: PET/MRI and PET/CT positive; 2: PET/MRI positive, PET/CT positive in retrospect; 3: PET/CT positive, PET/MRI positive in retrospect; 4: PET/MRI positive, PET/CT negative; 5: PET/MRI negative, PET/CT positive) by consensus. Patients with no lesions on either study or greater than 10 lesions based on either modality were excluded from the study. Results Fifty-two patients (mean±SD age: 58±14 years) underwent the dual imaging protocol; of these, 29 patients with a total of 93 FDG-avid lesions met the inclusion criteria. The majority of lesions (56%) were recorded prospectively in the same location on PET/CT and PET/MRI. About an equal small fraction of lesions were seen on PET/CT but only retrospectively on PET/MRI (9%) and vice versa (12%). More lesions were identified only on PET/MRI but not on PET/CT, even in retrospect (96% vs. 81%, respectively; p = 0.003). Discrepant lesions had lower maximum standardized uptake value (SUVmax) than concordant lesions on both modalities (p<0.001). Conclusions While most lesions were identified prospectively on both modalities, significantly more lesions were identified with PET/MRI than with PET/CT. PMID:28103230

  1. PET with radiolabeled aminoacid.

    PubMed

    Crippa, F; Alessi, A; Serafini, G L

    2012-04-01

    Since the clinical introduction of FDG, neuroimaging has been the first area of PET application in oncology. Later, while FDG-PET became progressively a key imaging modality in the management of the majority of malignancies outside the brain, its neuro-oncologic indications faced some limitations because of the unfavourable characteristics of FDG as brain tumor-seeking agent. PET applications in neuro-oncology have received new effectiveness by the advent of positron-emission labelled amino acids, so that it has been coined the term "Amino acid PET" to differentiate this imaging tool from FDG-PET. Radiolabeled amino acids are a very interesting class of PET tracers with great diagnostic potential in neuro-oncology because of their low uptake in normal brain and, conversely, high uptake in most brain tumors including low-grade gliomas. The present article surveys the results obtained using L-[methyl-11C]Methionine (MET), that has been the ancestor of PET amino acid tracers and is still the most popular amino acid imaging modality in oncology, and stresses the important role that this diagnostic modality can play in the evaluation of brain tumors. However, the use of MET is restricted to PET centers with an in-house cyclotron and radiochemistry facility, because of the short half-life (20 min) of 11C. The promising results of MET have stimulated the development of 18F-labelled aminoacid tracers, particularly O-(2-18F-fluoeoethyl1)-L-tyrosine (FET), that has the same properties of MET and, thanks to the longer half-life of 18F (about 110 min), allows a distribution strategy from a production tracer site to user satellite PET centers. Considering a more widespread use of Amino acid PET, together with the recent development of integrated PET-MRI imaging systems, and the oncoming clinical validation of other interesting PET tracers, i.e. FMISO or 18F-FAZA for hypoxia imaging and FLT for tumor proliferation imaging, it can be reasonably expected that metabolic imaging

  2. Improving PET spatial resolution and detectability for prostate cancer imaging

    NASA Astrophysics Data System (ADS)

    Bal, H.; Guerin, L.; Casey, M. E.; Conti, M.; Eriksson, L.; Michel, C.; Fanti, S.; Pettinato, C.; Adler, S.; Choyke, P.

    2014-08-01

    Prostate cancer, one of the most common forms of cancer among men, can benefit from recent improvements in positron emission tomography (PET) technology. In particular, better spatial resolution, lower noise and higher detectability of small lesions could be greatly beneficial for early diagnosis and could provide a strong support for guiding biopsy and surgery. In this article, the impact of improved PET instrumentation with superior spatial resolution and high sensitivity are discussed, together with the latest development in PET technology: resolution recovery and time-of-flight reconstruction. Using simulated cancer lesions, inserted in clinical PET images obtained with conventional protocols, we show that visual identification of the lesions and detectability via numerical observers can already be improved using state of the art PET reconstruction methods. This was achieved using both resolution recovery and time-of-flight reconstruction, and a high resolution image with 2 mm pixel size. Channelized Hotelling numerical observers showed an increase in the area under the LROC curve from 0.52 to 0.58. In addition, a relationship between the simulated input activity and the area under the LROC curve showed that the minimum detectable activity was reduced by more than 23%.

  3. Optical imaging modalities: From design to diagnosis of skin cancer

    NASA Astrophysics Data System (ADS)

    Korde, Vrushali Raj

    This study investigates three high resolution optical imaging modalities to better detect and diagnose skin cancer. The ideal high resolution optical imaging system can visualize pre-malignant tissue growth non-invasively with resolution comparable to histology. I examined 3 modalities which approached this goal. The first method examined was high magnification microscopy of thin stained tissue sections, together with a statistical analysis of nuclear chromatin patterns termed Karyometry. This method has subcellular resolution, but it necessitates taking a biopsy at the desired tissue site and imaging the tissue ex-vivo. My part of this study was to develop an automated nuclear segmentation algorithm to segment cell nuclei in skin histology images for karyometric analysis. The results of this algorithm were compared to hand segmented cell nuclei in the same images, and it was concluded that the automated segmentations can be used for karyometric analysis. The second optical imaging modality I investigated was Optical Coherence Tomography (OCT). OCT is analogous to ultrasound, in which sound waves are delivered into the body and the echo time and reflected signal magnitude are measured. Due to the fast speed of light and detector temporal integration times, low coherence interferometry is needed to gate the backscattered light. OCT acquires cross sectional images, and has an axial resolution of 1-15 mum (depending on the source bandwidth) and a lateral resolution of 10-20 mum (depending on the sample arm optics). While it is not capable of achieving subcellular resolution, it is a non-invasive imaging modality. OCT was used in this study to evaluate skin along a continuum from normal to sun damaged to precancer. I developed algorithms to detect statistically significant differences between images of sun protected and sun damaged skin, as well as between undiseased and precancerous skin. An Optical Coherence Microscopy (OCM) endoscope was developed in the third

  4. Polyaspartic acid coated iron oxide nanoprobes for PET/MRI imaging.

    PubMed

    Cowger, Taku; Xie, Jin

    2013-01-01

    Iron oxide nanoparticles, due to their exceptional magnetic property, biocompatibility, and biodegradability, have long been studied as contrast agents for magnetic resonance imaging (Xie et al., Curr Med Chem 16(10):1278-1294, 2009; Xie et al., Adv Drug deliv Rev 62(11):1064-1079, 2010). While previous applications mostly target reticuloendothelial system (RES) organs such as liver and lymph nodes, recent efforts have been made to impart targeting peptides or antibodies onto particle surface to enable site-specific targeting after systemic administration (Xie et al., Adv Drug Deliv Rev 62(11):1064-1079, 2010; Cai and Chen, Small 3(11):1840-1854, 2007; Corot et al., Adv Drug Deliv Rev 58 (14):1471-1504, 2006; Xie et al., Acc Chem Res 44(10):883-892). Moreover, other imaging functionalities can be loaded onto nanoparticles to achieve multimodality imaging probes (Cai and Chen, Small 3(11):1840-1854, 2007; Lee et al., J Nucl Med Soc Nucl Med 49(8):1371-1379, 2008). In this protocol, we describe the procedure of constructing an iron oxide nanoparticle (IONP)-based probe with high affinity towards integrin αvβ3 for positron emission tomography (PET) and magnetic resonance imaging (MRI) dual modality imaging. The related characterizations and validation experiments, including particle concentration determination, Prussian blue staining, animal model preparation, and in vivo PET/MRI imaging will also be discussed.

  5. Metabolic PET Imaging in Cancer Detection and Therapy Response

    PubMed Central

    Zhu, Aizhi; Lee, Daniel; Shim, Hyunsuk

    2010-01-01

    Positron emission tomography (PET) is a noninvasive imaging technique that provides a functional or metabolic assessment of normal tissue or disease conditions. 18F-fluorodeoxyglucose PET imaging (FDG-PET) is widely used clinically for tumor imaging due to increased glucose metabolism in most types of tumors, and has been shown to improve the diagnosis and subsequent treatment of cancers. In this chapter, we review its use in cancer diagnosis, staging, restaging, and assessment of response to treatment. In addition, other metabolic PET imaging agents in research or clinical trial stages are discussed, including amino acid analogs based on increased protein synthesis, and choline, which is based on increased membrane lipid synthesis. Amino acid analogs and choline are more specific to tumor cells than FDG, so they play an important role in differentiating cancers from benign conditions and in the diagnosis of cancers with low FDG uptake or high background FDG uptake. For decades, researchers have shown that tumors have altered metabolic profiles and display elevated uptake of glucose, amino acids, and lipids, which can be used for cancer diagnosis and monitoring of the therapeutic response with excellent signal-to-noise ratios. PMID:21362516

  6. Early Recognition of Chronic Traumatic Encephalopathy through FDDNP PET Imaging

    DTIC Science & Technology

    2014-10-01

    cumulative head trauma. All operational aspects of this study have been accomplished including local IRB approval, identification of potential... head injuries sustained in battle have been associated with the development of chronic traumatic encephalopathy (CTE). Pathological series have...will examine whether FDDNP PET imaging correlates with, and/or can predict, decline in cognitive function in those exposed to cumulative head trauma

  7. Imaging modalities in mild traumatic brain injury and sports concussion.

    PubMed

    Gonzalez, Peter G; Walker, Matthew T

    2011-10-01

    Mild traumatic brain injury is a significant public health issue that has been gaining considerable attention over the past few years. After injury, a large percentage of patients experience postconcussive symptoms that affect work and school performance and that carry significant medicolegal implications. Conventional imaging modalities (computed tomography and magnetic resonance imaging) are insensitive to microstructural changes and underestimate the degree of diffuse axonal injury and metabolic changes. Newer imaging techniques have attempted to better diagnose and characterize diffuse axonal injury and the metabolic and functional aspects of traumatic brain injury. The following review article summarizes the currently available imaging studies and describes the novel and more investigational techniques available for mild traumatic brain injury. A suggested algorithm is offered.

  8. Utility of noninvasive imaging modalities in a retina practice

    PubMed Central

    Jayadev, Chaitra; Jain, Nimesh; Sachdev, Sonia; Mohan, Ashwin; Yadav, Naresh Kumar

    2016-01-01

    Fluorescein angiography (FFA) has been the gold standard to understand, diagnose and treat retinal disorders. However, being an invasive procedure it has several limitations including adverse drug reactions. Hence, noninvasive tests that can be repeated during the course of the disease are the need of the hour. The aim of our study was to compare images of patients with retinal microvasculature pathology taken from three different imaging modalities (invasive vs. noninvasive). Lesions were detected more easily and with a greater resolution of morphology on retinal function imaging (RFI) and optical coherence tomography angiography (angio-OCT). Functional integrity of the vessels was better delineated on FFA. RFI and angio-OCT are noninvasive rapid and efficient methods to image vascular conditions with easy repeatability and negligible adverse effects. PMID:28112141

  9. Multi-modal automatic montaging of adaptive optics retinal images

    PubMed Central

    Chen, Min; Cooper, Robert F.; Han, Grace K.; Gee, James; Brainard, David H.; Morgan, Jessica I. W.

    2016-01-01

    We present a fully automated adaptive optics (AO) retinal image montaging algorithm using classic scale invariant feature transform with random sample consensus for outlier removal. Our approach is capable of using information from multiple AO modalities (confocal, split detection, and dark field) and can accurately detect discontinuities in the montage. The algorithm output is compared to manual montaging by evaluating the similarity of the overlapping regions after montaging, and calculating the detection rate of discontinuities in the montage. Our results show that the proposed algorithm has high alignment accuracy and a discontinuity detection rate that is comparable (and often superior) to manual montaging. In addition, we analyze and show the benefits of using multiple modalities in the montaging process. We provide the algorithm presented in this paper as open-source and freely available to download. PMID:28018714

  10. Multi-modal automatic montaging of adaptive optics retinal images.

    PubMed

    Chen, Min; Cooper, Robert F; Han, Grace K; Gee, James; Brainard, David H; Morgan, Jessica I W

    2016-12-01

    We present a fully automated adaptive optics (AO) retinal image montaging algorithm using classic scale invariant feature transform with random sample consensus for outlier removal. Our approach is capable of using information from multiple AO modalities (confocal, split detection, and dark field) and can accurately detect discontinuities in the montage. The algorithm output is compared to manual montaging by evaluating the similarity of the overlapping regions after montaging, and calculating the detection rate of discontinuities in the montage. Our results show that the proposed algorithm has high alignment accuracy and a discontinuity detection rate that is comparable (and often superior) to manual montaging. In addition, we analyze and show the benefits of using multiple modalities in the montaging process. We provide the algorithm presented in this paper as open-source and freely available to download.

  11. Enhancing image classification models with multi-modal biomarkers

    NASA Astrophysics Data System (ADS)

    Caban, Jesus J.; Liao, David; Yao, Jianhua; Mollura, Daniel J.; Gochuico, Bernadette; Yoo, Terry

    2011-03-01

    Currently, most computer-aided diagnosis (CAD) systems rely on image analysis and statistical models to diagnose, quantify, and monitor the progression of a particular disease. In general, CAD systems have proven to be effective at providing quantitative measurements and assisting physicians during the decision-making process. As the need for more flexible and effective CADs continues to grow, questions about how to enhance their accuracy have surged. In this paper, we show how statistical image models can be augmented with multi-modal physiological values to create more robust, stable, and accurate CAD systems. In particular, this paper demonstrates how highly correlated blood and EKG features can be treated as biomarkers and used to enhance image classification models designed to automatically score subjects with pulmonary fibrosis. In our results, a 3-5% improvement was observed when comparing the accuracy of CADs that use multi-modal biomarkers with those that only used image features. Our results show that lab values such as Erythrocyte Sedimentation Rate and Fibrinogen, as well as EKG measurements such as QRS and I:40, are statistically significant and can provide valuable insights about the severity of the pulmonary fibrosis disease.

  12. Innovative LuYAP:Ce array for PET imaging

    NASA Astrophysics Data System (ADS)

    Cinti, M. N.; Scafe, R.; Bennati, P.; Lo Meo, S.; Frantellizzi, V.; Pellegrini, R.; De Vincentis, G.; Sacco, D.; Fabbri, A.; Pani, R.

    2017-03-01

    We present an imaging characterization of a 10 × 10 LuYAP array (2 × 2 × 10 mm3 pixels) with an innovative dielectric coating insulation (0.015 mm thick), in view of its possible use in a gamma camera for imaging positron emission tomography (PET) or in similar applications, e.g. as γ -prompt detector in hadron therapy. The particular assembly of this array was realized in order to obtain a packing fraction of 98%, improving detection efficiency and light collection. For imaging purpose, the array has been coupled with a selected Hamamatsu H10966-100 Multi Anode Photomultiplier read out by a customized 64 independent channels electronics. This tube presents a superbialkali photocathode with 38% of quantum efficiency, permitting to enhance energy resolution and consequently image quality. A pixel identification of about 0.5 mm at 662 keV was obtained, highlighting the potentiality of this detector in PET applications.

  13. TU-G-303-02: Robust Radiomics Methods for PET and CT Imaging

    SciTech Connect

    Aerts, H.

    2015-06-15

    ‘Radiomics’ refers to studies that extract a large amount of quantitative information from medical imaging studies as a basis for characterizing a specific aspect of patient health. Radiomics models can be built to address a wide range of outcome predictions, clinical decisions, basic cancer biology, etc. For example, radiomics models can be built to predict the aggressiveness of an imaged cancer, cancer gene expression characteristics (radiogenomics), radiation therapy treatment response, etc. Technically, radiomics brings together quantitative imaging, computer vision/image processing, and machine learning. In this symposium, speakers will discuss approaches to radiomics investigations, including: longitudinal radiomics, radiomics combined with other biomarkers (‘pan-omics’), radiomics for various imaging modalities (CT, MRI, and PET), and the use of registered multi-modality imaging datasets as a basis for radiomics. There are many challenges to the eventual use of radiomics-derived methods in clinical practice, including: standardization and robustness of selected metrics, accruing the data required, building and validating the resulting models, registering longitudinal data that often involve significant patient changes, reliable automated cancer segmentation tools, etc. Despite the hurdles, results achieved so far indicate the tremendous potential of this general approach to quantifying and using data from medical images. Specific applications of radiomics to be presented in this symposium will include: the longitudinal analysis of patients with low-grade gliomas; automatic detection and assessment of patients with metastatic bone lesions; image-based monitoring of patients with growing lymph nodes; predicting radiotherapy outcomes using multi-modality radiomics; and studies relating radiomics with genomics in lung cancer and glioblastoma. Learning Objectives: Understanding the basic image features that are often used in radiomic models. Understanding

  14. PET Imaging for Initial Staging and Therapy Assessment in Multiple Myeloma Patients

    PubMed Central

    Bailly, Clément; Leforestier, Rodolphe; Jamet, Bastien; Carlier, Thomas; Bourgeois, Mickael; Guérard, François; Touzeau, Cyrille; Moreau, Philippe; Chérel, Michel; Kraeber-Bodéré, Françoise; Bodet-Milin, Caroline

    2017-01-01

    Multiple myeloma (MM) is a hematological neoplasm characterized by the clonal proliferation of malignant plasma cells in the bone marrow. MM results in diffuse or focal bone infiltration and extramedullary lesions. Over the past two decades, advances have been made with regard to the diagnosis, staging, treatment, and imaging of MM. Computed tomography (CT) and magnetic resonance imaging (MRI) are currently recommended as the most effective imaging modalities at diagnostic. Yet, recent data from the literature suggest that positron emission tomography combined with computed tomography (PET/CT) using 18F-deoxyglucose (FDG) is a promising technique for initial staging and therapeutic monitoring in this pathology. This paper reviews the recent advances as well as the potential place of a more specific radiopharmaceutical in MM. PMID:28218709

  15. Predicting standard-dose PET image from low-dose PET and multimodal MR images using mapping-based sparse representation

    NASA Astrophysics Data System (ADS)

    Wang, Yan; Zhang, Pei; An, Le; Ma, Guangkai; Kang, Jiayin; Shi, Feng; Wu, Xi; Zhou, Jiliu; Lalush, David S.; Lin, Weili; Shen, Dinggang

    2016-01-01

    Positron emission tomography (PET) has been widely used in clinical diagnosis for diseases and disorders. To obtain high-quality PET images requires a standard-dose radionuclide (tracer) injection into the human body, which inevitably increases risk of radiation exposure. One possible solution to this problem is to predict the standard-dose PET image from its low-dose counterpart and its corresponding multimodal magnetic resonance (MR) images. Inspired by the success of patch-based sparse representation (SR) in super-resolution image reconstruction, we propose a mapping-based SR (m-SR) framework for standard-dose PET image prediction. Compared with the conventional patch-based SR, our method uses a mapping strategy to ensure that the sparse coefficients, estimated from the multimodal MR images and low-dose PET image, can be applied directly to the prediction of standard-dose PET image. As the mapping between multimodal MR images (or low-dose PET image) and standard-dose PET images can be particularly complex, one step of mapping is often insufficient. To this end, an incremental refinement framework is therefore proposed. Specifically, the predicted standard-dose PET image is further mapped to the target standard-dose PET image, and then the SR is performed again to predict a new standard-dose PET image. This procedure can be repeated for prediction refinement of the iterations. Also, a patch selection based dictionary construction method is further used to speed up the prediction process. The proposed method is validated on a human brain dataset. The experimental results show that our method can outperform benchmark methods in both qualitative and quantitative measures.

  16. Parametric myocardial perfusion PET imaging using physiological clustering

    NASA Astrophysics Data System (ADS)

    Mohy-ud-Din, Hassan; Karakatsanis, Nikolaos A.; Lodge, Martin A.; Tang, Jing; Rahmim, Arman

    2014-03-01

    We propose a novel framework of robust kinetic parameter estimation applied to absolute ow quanti cation in dynamic PET imaging. Kinetic parameter estimation is formulated as a nonlinear least squares with spatial constraints problem (NLLS-SC) where the spatial constraints are computed from a physiologically driven clustering of dynamic images, and used to reduce noise contamination. An ideal clustering of dynamic images depends on the underlying physiology of functional regions, and in turn, physiological processes are quanti ed by kinetic parameter estimation. Physiologically driven clustering of dynamic images is performed using a clustering algorithm (e.g. K-means, Spectral Clustering etc) with Kinetic modeling in an iterative handshaking fashion. This gives a map of labels where each functionally homogenous cluster is represented by mean kinetics (cluster centroid). Parametric images are acquired by solving the NLLS-SC problem for each voxel which penalizes spatial variations from its mean kinetics. This substantially reduces noise in the estimation process for each voxel by utilizing kinetic information from physiologically similar voxels (cluster members). Resolution degradation is also substantially minimized as no spatial smoothing between heterogeneous functional regions is performed. The proposed framework is shown to improve the quantitative accuracy of Myocardial Perfusion (MP) PET imaging, and in turn, has the long-term potential to enhance capabilities of MP PET in the detection, staging and management of coronary artery disease.

  17. Lung tumor segmentation in PET images using graph cuts.

    PubMed

    Ballangan, Cherry; Wang, Xiuying; Fulham, Michael; Eberl, Stefan; Feng, David Dagan

    2013-03-01

    The aim of segmentation of tumor regions in positron emission tomography (PET) is to provide more accurate measurements of tumor size and extension into adjacent structures, than is possible with visual assessment alone and hence improve patient management decisions. We propose a segmentation energy function for the graph cuts technique to improve lung tumor segmentation with PET. Our segmentation energy is based on an analysis of the tumor voxels in PET images combined with a standardized uptake value (SUV) cost function and a monotonic downhill SUV feature. The monotonic downhill feature avoids segmentation leakage into surrounding tissues with similar or higher PET tracer uptake than the tumor and the SUV cost function improves the boundary definition and also addresses situations where the lung tumor is heterogeneous. We evaluated the method in 42 clinical PET volumes from patients with non-small cell lung cancer (NSCLC). Our method improves segmentation and performs better than region growing approaches, the watershed technique, fuzzy-c-means, region-based active contour and tumor customized downhill.

  18. Current Imaging Modalities for assessing Ocular Blood Flow in Glaucoma.

    PubMed

    Mohindroo, Chirayu; Ichhpujani, Parul; Kumar, Suresh

    2016-01-01

    Glaucoma may be caused by an interplay of elevated intraocular pressure (IOP), vascular, genetic, anatomical, brain, and immune factors. The direct assessment of ocular hemodynam-ics offers promise for glaucoma detection, differentiation, and possibly new treatment modalities. All the methods currently in use to measure ocular blood flow have inherent limitations and measure different aspects of ocular blood flow. This review article attempts to provide detailed information on ocular perfu-sion pressure as well as an overview of the newly developed imaging technologies used to investigate ocular blood flow in glaucoma patients.

  19. Automated Movement Correction for Dynamic PET/CT Images: Evaluation with Phantom and Patient Data

    PubMed Central

    Ye, Hu; Wong, Koon-Pong; Wardak, Mirwais; Dahlbom, Magnus; Kepe, Vladimir; Barrio, Jorge R.; Nelson, Linda D.; Small, Gary W.; Huang, Sung-Cheng

    2014-01-01

    Head movement during a dynamic brain PET/CT imaging results in mismatch between CT and dynamic PET images. It can cause artifacts in CT-based attenuation corrected PET images, thus affecting both the qualitative and quantitative aspects of the dynamic PET images and the derived parametric images. In this study, we developed an automated retrospective image-based movement correction (MC) procedure. The MC method first registered the CT image to each dynamic PET frames, then re-reconstructed the PET frames with CT-based attenuation correction, and finally re-aligned all the PET frames to the same position. We evaluated the MC method's performance on the Hoffman phantom and dynamic FDDNP and FDG PET/CT images of patients with neurodegenerative disease or with poor compliance. Dynamic FDDNP PET/CT images (65 min) were obtained from 12 patients and dynamic FDG PET/CT images (60 min) were obtained from 6 patients. Logan analysis with cerebellum as the reference region was used to generate regional distribution volume ratio (DVR) for FDDNP scan before and after MC. For FDG studies, the image derived input function was used to generate parametric image of FDG uptake constant (Ki) before and after MC. Phantom study showed high accuracy of registration between PET and CT and improved PET images after MC. In patient study, head movement was observed in all subjects, especially in late PET frames with an average displacement of 6.92 mm. The z-direction translation (average maximum = 5.32 mm) and x-axis rotation (average maximum = 5.19 degrees) occurred most frequently. Image artifacts were significantly diminished after MC. There were significant differences (P<0.05) in the FDDNP DVR and FDG Ki values in the parietal and temporal regions after MC. In conclusion, MC applied to dynamic brain FDDNP and FDG PET/CT scans could improve the qualitative and quantitative aspects of images of both tracers. PMID:25111700

  20. Automated movement correction for dynamic PET/CT images: evaluation with phantom and patient data.

    PubMed

    Ye, Hu; Wong, Koon-Pong; Wardak, Mirwais; Dahlbom, Magnus; Kepe, Vladimir; Barrio, Jorge R; Nelson, Linda D; Small, Gary W; Huang, Sung-Cheng

    2014-01-01

    Head movement during a dynamic brain PET/CT imaging results in mismatch between CT and dynamic PET images. It can cause artifacts in CT-based attenuation corrected PET images, thus affecting both the qualitative and quantitative aspects of the dynamic PET images and the derived parametric images. In this study, we developed an automated retrospective image-based movement correction (MC) procedure. The MC method first registered the CT image to each dynamic PET frames, then re-reconstructed the PET frames with CT-based attenuation correction, and finally re-aligned all the PET frames to the same position. We evaluated the MC method's performance on the Hoffman phantom and dynamic FDDNP and FDG PET/CT images of patients with neurodegenerative disease or with poor compliance. Dynamic FDDNP PET/CT images (65 min) were obtained from 12 patients and dynamic FDG PET/CT images (60 min) were obtained from 6 patients. Logan analysis with cerebellum as the reference region was used to generate regional distribution volume ratio (DVR) for FDDNP scan before and after MC. For FDG studies, the image derived input function was used to generate parametric image of FDG uptake constant (Ki) before and after MC. Phantom study showed high accuracy of registration between PET and CT and improved PET images after MC. In patient study, head movement was observed in all subjects, especially in late PET frames with an average displacement of 6.92 mm. The z-direction translation (average maximum = 5.32 mm) and x-axis rotation (average maximum = 5.19 degrees) occurred most frequently. Image artifacts were significantly diminished after MC. There were significant differences (P<0.05) in the FDDNP DVR and FDG Ki values in the parietal and temporal regions after MC. In conclusion, MC applied to dynamic brain FDDNP and FDG PET/CT scans could improve the qualitative and quantitative aspects of images of both tracers.

  1. Dual Modality Noncontact Photoacoustic and Spectral Domain OCT Imaging

    PubMed Central

    Leiss-Holzinger, Elisabeth; Bauer-Marschallinger, Johannes; Hochreiner, Armin; Hollinger, Philipp; Berer, Thomas

    2016-01-01

    We developed a multimodal imaging system, combining noncontact photoacoustic imaging and optical coherence tomography (OCT). Photoacoustic signals are recorded without contact to the specimens’ surface by using an interferometric technique. The interferometer is realized within a fiber-optic network using a fiber laser at 1550 nm as source. The fiber-optic network allows the integration of a fiber-based OCT system operating at a wavelength region around 1310 nm. Light from the fiber laser and the OCT source are multiplexed into one fiber using wavelength-division multiplexing. The same focusing optics is used for both modalities. Back-reflected light from the sample is demultiplexed and guided to the respective imaging systems. As the same optical components are used for OCT and photoacoustic imaging, the obtained images are co-registered intrinsically in lateral direction. Three-dimensional imaging is implemented by hybrid galvanometer and mechanical scanning. To allow fast B-scan measurements, scanning of the interrogation beam along one dimension is executed by a galvanometer scanner. Slow-axis scanning, perpendicular to the fast axis, is performed utilizing a linear translational stage. We demonstrate two-dimensional and three-dimensional imaging on agarose phantoms. PMID:25900968

  2. Photoacoustic and ultrasound dual-modality imaging for inflammatory arthritis

    NASA Astrophysics Data System (ADS)

    Xu, Guan; Chamberland, David; Girish, Gandikota; Wang, Xueding

    2014-03-01

    Arthritis is a leading cause of disability, affecting 46 million of the population in the U.S. Rendering new optical contrast in articular tissues at high spatial and temporal resolution, emerging photoacoustic imaging (PAI) combined with more established ultrasound (US) imaging technologies provides unique opportunities for diagnosis and treatment monitoring of inflammatory arthritis. In addition to capturing peripheral bone and soft tissue images, PAI has the capability to quantify hemodynamic properties including regional blood oxygenation and blood volume, both abnormal in synovial tissues affected by arthritis. Therefore, PAI, especially when performed together with US, should be of considerable help for further understanding the pathophysiology of arthritis as well as assisting in therapeutic decisions, including assessing the efficacy of new pharmacological therapies. In this paper, we will review our recent work on the development of PAI for application to the diagnostic imaging and therapeutic monitoring of inflammatory arthritis. We will present the imaging results from a home-built imaging system and another one based on a commercial US. The performance of PAI in evaluating pharmacological therapy on animal model of arthritis will be shown. Moreover, our resent work on PAI and US dual-modality imaging of human peripheral joints in vivo will also be presented.

  3. Dual Modality Noncontact Photoacoustic and Spectral Domain OCT Imaging.

    PubMed

    Leiss-Holzinger, Elisabeth; Bauer-Marschallinger, Johannes; Hochreiner, Armin; Hollinger, Philipp; Berer, Thomas

    2016-01-01

    We developed a multimodal imaging system, combining noncontact photoacoustic imaging and optical coherence tomography (OCT). Photoacoustic signals are recorded without contact to the specimens' surface by using an interferometric technique. The interferometer is realized within a fiber-optic network using a fiber laser at 1550 nm as source. The fiber-optic network allows the integration of a fiber-based OCT system operating at a wavelength region around 1310 nm. Light from the fiber laser and the OCT source are multiplexed into one fiber using wavelength-division multiplexing. The same focusing optics is used for both modalities. Back-reflected light from the sample is demultiplexed and guided to the respective imaging systems. As the same optical components are used for OCT and photoacoustic imaging, the obtained images are co-registered intrinsically in lateral direction. Three-dimensional imaging is implemented by hybrid galvanometer and mechanical scanning. To allow fast B-scan measurements, scanning of the interrogation beam along one dimension is executed by a galvanometer scanner. Slow-axis scanning, perpendicular to the fast axis, is performed utilizing a linear translational stage. We demonstrate two-dimensional and three-dimensional imaging on agarose phantoms.

  4. Data Acquisition and Image Reconstruction Systems from the miniPET Scanners to the CARDIOTOM Camera

    NASA Astrophysics Data System (ADS)

    Valastván, I.; Imrek, J.; Hegyesi, G.; Molnár, J.; Novák, D.; Bone, D.; Kerek, A.

    2007-11-01

    Nuclear imaging devices play an important role in medical diagnosis as well as drug research. The first and second generation data acquisition systems and the image reconstruction library developed provide a unified hardware and software platform for the miniPET-I, miniPET-II small animal PET scanners and for the CARDIOTOM™.

  5. A small animal PET based on GAPDs and charge signal transmission approach for hybrid PET-MR imaging

    NASA Astrophysics Data System (ADS)

    Kang, Jihoon; Choi, Yong; Hong, Key Jo; Hu, Wei; Jung, Jin Ho; Huh, Yoonsuk; Kim, Byung-Tae

    2011-08-01

    Positron emission tomography (PET) employing Geiger-mode avalanche photodiodes (GAPDs) and charge signal transmission approach was developed for small animal imaging. Animal PET contained 16 LYSO and GAPD detector modules that were arranged in a 70 mm diameter ring with an axial field of view of 13 mm. The GAPDs charge output signals were transmitted to a preamplifier located remotely using 300 cm flexible flat cables. The position decoder circuits (PDCs) were used to multiplex the PET signals from 256 to 4 channels. The outputs of the PDCs were digitized and further-processed in the data acquisition unit. The cross-compatibilities of the PET detectors and MRI were assessed outside and inside the MRI. Experimental studies of the developed full ring PET were performed to examine the spatial resolution and sensitivity. Phantom and mouse images were acquired to examine the imaging performance. The mean energy and time resolution of the PET detector were 17.6% and 1.5 ns, respectively. No obvious degradation on PET and MRI was observed during simultaneous PET-MRI data acquisition. The measured spatial resolution and sensitivity at the CFOV were 2.8 mm and 0.7%, respectively. In addition, a 3 mm diameter line source was clearly resolved in the hot-sphere phantom images. The reconstructed transaxial PET images of the mouse brain and tumor displaying the glucose metabolism patterns were imaged well. These results demonstrate GAPD and the charge signal transmission approach can allow the development of high performance small animal PET with improved MR compatibility.

  6. Gallium-68 Prostate-Specific Membrane Antigen PET Imaging.

    PubMed

    Hofman, Michael S; Iravani, Amir

    2017-04-01

    The role of gallium-68 ((68)Ga) prostate-specific membrane antigen (PSMA) PET imaging is evolving and finding its place in the imaging armamentarium for prostate cancer (PCa). Despite the progress of conventional imaging strategies, significant limitations remain, including identification of small-volume disease and assessment of bone. Clinical studies have demonstrated that (68)Ga-PSMA is a promising tracer for detection of PCa metastases, even in patients with low prostate-specific antigen. To provide an accurate interpretation of (68)Ga-PSMA PET/computed tomography, nuclear medicine specialists and radiologists should be familiar with physiologic (68)Ga-PSMA uptake, common variants, patterns of locoregional and distant spread of PCa, and inherent pitfalls.

  7. Energy dependence of scatter components in multispectral PET imaging.

    PubMed

    Bentourkia, M; Msaki, P; Cadorette, J; Lecomte, R

    1995-01-01

    High resolution images in PET based on small individual detectors are obtained at the cost of low sensitivity and increased detector scatter. These limitations can be partially overcome by enlarging discrimination windows to include more low-energy events and by developing more efficient energy-dependent methods to correct for scatter radiation from all sources. The feasibility of multispectral scatter correction was assessed by decomposing response functions acquired in multiple energy windows into four basic components: object, collimator and detector scatter, and trues. The shape and intensity of these components are different and energy-dependent. They are shown to contribute to image formation in three ways: useful (true), potentially useful (detector scatter), and undesirable (object and collimator scatter) information to the image over the entire energy range. With the Sherbrooke animal PET system, restoration of detector scatter in every energy window would allow nearly 90% of all detected events to participate in image formation. These observations suggest that multispectral acquisition is a promising solution for increasing sensitivity in high resolution PET. This can be achieved without loss of image quality if energy-dependent methods are made available to preserve useful events as potentially useful events are restored and undesirable events removed.

  8. PET image reconstruction: mean, variance, and optimal minimax criterion

    NASA Astrophysics Data System (ADS)

    Liu, Huafeng; Gao, Fei; Guo, Min; Xue, Liying; Nie, Jing; Shi, Pengcheng

    2015-04-01

    Given the noise nature of positron emission tomography (PET) measurements, it is critical to know the image quality and reliability as well as expected radioactivity map (mean image) for both qualitative interpretation and quantitative analysis. While existing efforts have often been devoted to providing only the reconstructed mean image, we present a unified framework for joint estimation of the mean and corresponding variance of the radioactivity map based on an efficient optimal min-max criterion. The proposed framework formulates the PET image reconstruction problem to be a transformation from system uncertainties to estimation errors, where the minimax criterion is adopted to minimize the estimation errors with possibly maximized system uncertainties. The estimation errors, in the form of a covariance matrix, express the measurement uncertainties in a complete way. The framework is then optimized by ∞-norm optimization and solved with the corresponding H∞ filter. Unlike conventional statistical reconstruction algorithms, that rely on the statistical modeling methods of the measurement data or noise, the proposed joint estimation stands from the point of view of signal energies and can handle from imperfect statistical assumptions to even no a priori statistical assumptions. The performance and accuracy of reconstructed mean and variance images are validated using Monte Carlo simulations. Experiments on phantom scans with a small animal PET scanner and real patient scans are also conducted for assessment of clinical potential.

  9. Multi-modality imaging of tumor phenotype and response to therapy

    NASA Astrophysics Data System (ADS)

    Nyflot, Matthew J.

    2011-12-01

    Imaging and radiation oncology have historically been closely linked. However, the vast majority of techniques used in the clinic involve anatomical imaging. Biological imaging offers the potential for innovation in the areas of cancer diagnosis and staging, radiotherapy target definition, and treatment response assessment. Some relevant imaging techniques are FDG PET (for imaging cellular metabolism), FLT PET (proliferation), CuATSM PET (hypoxia), and contrast-enhanced CT (vasculature and perfusion). Here, a technique for quantitative spatial correlation of tumor phenotype is presented for FDG PET, FLT PET, and CuATSM PET images. Additionally, multimodality imaging of treatment response with FLT PET, CuATSM, and dynamic contrast-enhanced CT is presented, in a trial of patients receiving an antiangiogenic agent (Avastin) combined with cisplatin and radiotherapy. Results are also presented for translational applications in animal models, including quantitative assessment of proliferative response to cetuximab with FLT PET and quantification of vascular volume with a blood-pool contrast agent (Fenestra). These techniques have clear applications to radiobiological research and optimized treatment strategies, and may eventually be used for personalized therapy for patients.

  10. PET-Computed Tomography in Veterinary Medicine.

    PubMed

    Randall, Elissa K

    2016-05-01

    PET/CT is an advanced imaging modality that is becoming more commonly used in veterinary medicine. It is most commonly used to image patients with cancer, and the most frequently used radiopharmaceutical is F-18 FDG. F-18 FDG is a glucose analog that highlights areas of increased glucose metabolism on the PET images. CT images provide excellent anatomic depiction and aid in interpretation of the PET data. Many types of cancer are hypermetabolic on PET/CT scans, but normal structures and areas of inflammation are also hypermetabolic, so knowledge of normal imaging and cytologic or histopathologic evaluation of lesions is essential.

  11. Novel Preparation Methods of 52Mn for ImmunoPET Imaging

    PubMed Central

    Graves, Stephen A.; Hernandez, Reinier; Fonslet, Jesper; England, Christopher G.; Valdovinos, Hector F.; Ellison, Paul A.; Barnhart, Todd E.; Elema, Dennis R.; Theuer, Charles P.; Cai, Weibo; Nickles, Robert J.; Severin, Gregory W.

    2015-01-01

    52Mn (t1/2 = 5.59 d, β+ = 29.6%, Eβave = 0.24 MeV) shows promise in positron emission tomography (PET) and in dual-modality manganese-enhanced magnetic resonance imaging (MEMRI) applications including neural tractography, stem cell tracking, and biological toxicity studies. The extension to bioconjugate application requires high-specific-activity 52Mn in a state suitable for macromolecule labeling. To that end a 52Mn production, purification, and labeling system is presented, and its applicability in preclinical, macromolecule PET is shown using the conjugate 52Mn-DOTA-TRC105. 52Mn is produced by 60 μA, 16 MeV proton irradiation of natural chromium metal pressed into a silver disc support. Radiochemical separation proceeds by strong anion exchange chromatography of the dissolved Cr target, employing a semiorganic mobile phase, 97:3 (v:v) ethanol:HCl (11 M, aqueous). The method is 62 ± 14% efficient (n = 7) in 52Mn recovery, leading to a separation factor from Cr of (1.6 ± 1.0) × 106 (n = 4), and an average effective specific activity of 0.8 GBq/μmol (n = 4) in titration against DOTA. 52Mn-DOTA-TRC105 conjugation and labeling demonstrate the potential for chelation applications. In vivo images acquired using PET/CT in mice bearing 4T1 xenograft tumors are presented. Peak tumor uptake is 18.7 ± 2.7%ID/g at 24 h post injection and ex vivo 52Mn biodistribution validates the in vivo PET data. Free 52Mn2+ (as chloride or acetate) is used as a control in additional mice to evaluate the nontargeted biodistribution in the tumor model. PMID:26317429

  12. Silicon detectors for combined MR-PET and MR-SPECT imaging

    NASA Astrophysics Data System (ADS)

    Studen, A.; Brzezinski, K.; Chesi, E.; Cindro, V.; Clinthorne, N. H.; Cochran, E.; Grošičar, B.; Grkovski, M.; Honscheid, K.; Kagan, H.; Lacasta, C.; Llosa, G.; Mikuž, M.; Stankova, V.; Weilhammer, P.; Žontar, D.

    2013-02-01

    Silicon based devices can extend PET-MR and SPECT-MR imaging to applications, where their advantages in performance outweigh benefits of high statistical counts. Silicon is in many ways an excellent detector material with numerous advantages, among others: excellent energy and spatial resolution, mature processing technology, large signal to noise ratio, relatively low price, availability, versatility and malleability. The signal in silicon is also immune to effects of magnetic field at the level normally used in MR devices. Tests in fields up to 7 T were performed in a study to determine effects of magnetic field on positron range in a silicon PET device. The curvature of positron tracks in direction perpendicular to the field's orientation shortens the distance between emission and annihilation point of the positron. The effect can be fully appreciated for a rotation of the sample for a fixed field direction, compressing range in all dimensions. A popular Ga-68 source was used showing a factor of 2 improvement in image noise compared to zero field operation. There was also a little increase in noise as the reconstructed resolution varied between 2.5 and 1.5 mm. A speculative applications can be recognized in both emission modalities, SPECT and PET. Compton camera is a subspecies of SPECT, where a silicon based scatter as a MR compatible part could inserted into the MR bore and the secondary detector could operate in less constrained environment away from the magnet. Introducing a Compton camera also relaxes requirements of the radiotracers used, extending the range of conceivable photon energies beyond 140.5 keV of the Tc-99m. In PET, one could exploit the compressed sub-millimeter range of positrons in the magnetic field. To exploit the advantage, detectors with spatial resolution commensurate to the effect must be used with silicon being an excellent candidate. Measurements performed outside of the MR achieving spatial resolution below 1 mm are reported.

  13. MR-DTI and PET multimodal imaging of dopamine release within subdivisions of basal ganglia

    NASA Astrophysics Data System (ADS)

    Tziortzi, A.; Searle, G.; Tsoumpas, C.; Long, C.; Shotbolt, P.; Rabiner, E.; Jenkinson, M.; Gunn, R. N.

    2011-09-01

    The basal ganglia is a group of anatomical nuclei, functionally organised into limbic, associative and sensorimotor regions, which plays a central role in dopamine related neurological and psychiatric disorders. In this study, we combine two imaging modalities to enable the measurement of dopamine release in functionally related subdivisions of the basal ganglia. [11C]-(+)-PHNO Positron Emission Tomography (PET) measurements in the living human brain pre- and post-administration of amphetamine allow for the estimation of regional dopamine release. Combined Magnetic Resonance Diffusion Tensor Imaging (MR-DTI) data allows for the definition of functional territories of the basal ganglia from connectivity information. The results suggest that there is a difference in dopamine release among the connectivity derived functional subdivisions. Dopamine release is highest in the limbic area followed by the sensorimotor and then the associative area with this pattern reflected in both striatum and pallidum.

  14. High resolution PET breast imager with improved detection efficiency

    DOEpatents

    Majewski, Stanislaw

    2010-06-08

    A highly efficient PET breast imager for detecting lesions in the entire breast including those located close to the patient's chest wall. The breast imager includes a ring of imaging modules surrounding the imaged breast. Each imaging module includes a slant imaging light guide inserted between a gamma radiation sensor and a photodetector. The slant light guide permits the gamma radiation sensors to be placed in close proximity to the skin of the chest wall thereby extending the sensitive region of the imager to the base of the breast. Several types of photodetectors are proposed for use in the detector modules, with compact silicon photomultipliers as the preferred choice, due to its high compactness. The geometry of the detector heads and the arrangement of the detector ring significantly reduce dead regions thereby improving detection efficiency for lesions located close to the chest wall.

  15. Improved proton computed tomography by dual modality image reconstruction

    SciTech Connect

    Hansen, David C. Bassler, Niels; Petersen, Jørgen Breede Baltzer; Sørensen, Thomas Sangild

    2014-03-15

    Purpose: Proton computed tomography (CT) is a promising image modality for improving the stopping power estimates and dose calculations for particle therapy. However, the finite range of about 33 cm of water of most commercial proton therapy systems limits the sites that can be scanned from a full 360° rotation. In this paper the authors propose a method to overcome the problem using a dual modality reconstruction (DMR) combining the proton data with a cone-beam x-ray prior. Methods: A Catphan 600 phantom was scanned using a cone beam x-ray CT scanner. A digital replica of the phantom was created in the Monte Carlo code Geant4 and a 360° proton CT scan was simulated, storing the entrance and exit position and momentum vector of every proton. Proton CT images were reconstructed using a varying number of angles from the scan. The proton CT images were reconstructed using a constrained nonlinear conjugate gradient algorithm, minimizing total variation and the x-ray CT prior while remaining consistent with the proton projection data. The proton histories were reconstructed along curved cubic-spline paths. Results: The spatial resolution of the cone beam CT prior was retained for the fully sampled case and the 90° interval case, with the MTF = 0.5 (modulation transfer function) ranging from 5.22 to 5.65 linepairs/cm. In the 45° interval case, the MTF = 0.5 dropped to 3.91 linepairs/cm For the fully sampled DMR, the maximal root mean square (RMS) error was 0.006 in units of relative stopping power. For the limited angle cases the maximal RMS error was 0.18, an almost five-fold improvement over the cone beam CT estimate. Conclusions: Dual modality reconstruction yields the high spatial resolution of cone beam x-ray CT while maintaining the improved stopping power estimation of proton CT. In the case of limited angles, the use of prior image proton CT greatly improves the resolution and stopping power estimate, but does not fully achieve the quality of a 360

  16. Imaging quality of (44)Sc in comparison with five other PET radionuclides using Derenzo phantoms and preclinical PET.

    PubMed

    Bunka, Maruta; Müller, Cristina; Vermeulen, Christiaan; Haller, Stephanie; Türler, Andreas; Schibli, Roger; van der Meulen, Nicholas P

    2016-04-01

    PET is the favored nuclear imaging technique because of the high sensitivity and resolution it provides, as well as the possibility for quantification of accumulated radioactivity. (44)Sc (T1/2=3.97h, Eβ(+)=632keV) was recently proposed as a potentially interesting radionuclide for PET. The aim of this study was to investigate the image quality, which can be obtained with (44)Sc, and compare it with five other, frequently employed PET nuclides using Derenzo phantoms and a small-animal PET scanner. The radionuclides were produced at the medical cyclotron at CRS, ETH Zurich ((11)C, (18)F), at the Injector II research cyclotron at CRS, PSI ((64)Cu, (89)Zr, (44)Sc), as well as via a generator system ((68)Ga). Derenzo phantoms, containing solutions of each of these radionuclides, were scanned using a GE Healthcare eXplore VISTA small-animal PET scanner. The image resolution was determined for each nuclide by analysis of the intensity signal using the reconstructed PET data of a hole diameter of 1.3mm. The image quality of (44)Sc was compared to five frequently-used PET radionuclides. In agreement with the positron range, an increasing relative resolution was determined in the sequence of (68)Ga<(44)Sc<(89)Zr<(11)C<(64)Cu<(18)F. The performance of (44)Sc was in agreement with the theoretical expectations based on the energy of the emitted positrons.

  17. Phosphoramidate-based Peptidomimetic Prostate Cancer PET Imaging Agents

    DTIC Science & Technology

    2013-07-01

    develop a PET imaging agent based on modifying the peptidomimetic PSMA inhibitor which will result in improved tumor uptake and clearance mechanism...Different fluorination approaches were attempted with PSMA module compounds such as direct labeling, cupper free chemistry and the use of...labeling approaches are established, and then the labeling of the modified PSMA inhibitor analogues will be investigated in vitro as well as in vivo. 15

  18. Phosphoramidate-based Peptidomimetic Prostate Cancer PET Imaging Agents

    DTIC Science & Technology

    2013-11-01

    goal is to develop a PET imaging agent based on modifying the peptidomimetic PSMA inhibitor which will result in improved tumor uptake and clearance...mechanism. Different fluorination approaches were attempted with PSMA module compounds such as direct labeling, cupper free chemistry and the use of...the labeling approaches are established, and then the labeling of the modified PSMA inhibitor analogues will be investigated in vitro as well as in

  19. Prediction of CT Substitutes from MR Images Based on Local Diffeomorphic Mapping for Brain PET Attenuation Correction.

    PubMed

    Wu, Yao; Yang, Wei; Lu, Lijun; Lu, Zhentai; Zhong, Liming; Huang, Meiyan; Feng, Yanqiu; Feng, Qianjin; Chen, Wufan

    2016-10-01

    Attenuation correction is important for PET reconstruction. In PET/MR, MR intensities are not directly related to attenuation coefficients that are needed in PET imaging. The attenuation coefficient map can be derived from CT images. Therefore, prediction of CT substitutes from MR images is desired for attenuation correction in PET/MR.

  20. A computational pipeline for quantification of pulmonary infections in small animal models using serial PET-CT imaging

    PubMed Central

    2013-01-01

    Background Infectious diseases are the second leading cause of death worldwide. In order to better understand and treat them, an accurate evaluation using multi-modal imaging techniques for anatomical and functional characterizations is needed. For non-invasive imaging techniques such as computed tomography (CT), magnetic resonance imaging (MRI), and positron emission tomography (PET), there have been many engineering improvements that have significantly enhanced the resolution and contrast of the images, but there are still insufficient computational algorithms available for researchers to use when accurately quantifying imaging data from anatomical structures and functional biological processes. Since the development of such tools may potentially translate basic research into the clinic, this study focuses on the development of a quantitative and qualitative image analysis platform that provides a computational radiology perspective for pulmonary infections in small animal models. Specifically, we designed (a) a fast and robust automated and semi-automated image analysis platform and a quantification tool that can facilitate accurate diagnostic measurements of pulmonary lesions as well as volumetric measurements of anatomical structures, and incorporated (b) an image registration pipeline to our proposed framework for volumetric comparison of serial scans. This is an important investigational tool for small animal infectious disease models that can help advance researchers’ understanding of infectious diseases. Methods We tested the utility of our proposed methodology by using sequentially acquired CT and PET images of rabbit, ferret, and mouse models with respiratory infections of Mycobacterium tuberculosis (TB), H1N1 flu virus, and an aerosolized respiratory pathogen (necrotic TB) for a total of 92, 44, and 24 scans for the respective studies with half of the scans from CT and the other half from PET. Institutional Administrative Panel on Laboratory Animal

  1. PET Imaging with 89Zr: From Radiochemistry to the Clinic

    PubMed Central

    Deri, Melissa A.; Zeglis, Brian M.; Francesconi, Lynn C.; Lewis, Jason S.

    2012-01-01

    The advent of antibody-based cancer therapeutics has led to the concomitant rise in the development of companion diagnostics for these therapies, particularly nuclear imaging agents. A number of radioisotopes have been employed for antibody-based PET and SPECT imaging, notably 64Cu, 124I, 111In, and 99mTc; in recent years, however, the field has increasingly focused on 89Zr, a radiometal with near ideal physical and chemical properties for immunoPET imaging. In the review at hand, we seek to provide a comprehensive portrait of the current state of 89Zr radiochemical and imaging research, including work into the production and purification of the isotope, the synthesis of new chelators, the development of new bioconjugation strategies, the creation of novel 89Zr-based agents for preclinical imaging studies, and the translation of 89Zr-labeled radiopharmaceuticals to the clinic. Particular attention will also be dedicated to emerging trends in the field, 89Zr-based imaging applications using vectors other than antibodies, the comparative advantages and limitations of 89Zr-based imaging compared to that with other isotopes, and areas that would benefit from more extensive investigation. At bottom, it is hoped that this review will provide both the experienced investigator and new scientist with a full and critical overview of this exciting and fast-developing field. PMID:22998840

  2. Quantification of Lung PET Images: Challenges and Opportunities.

    PubMed

    Chen, Delphine L; Cheriyan, Joseph; Chilvers, Edwin R; Choudhury, Gourab; Coello, Christopher; Connell, Martin; Fisk, Marie; Groves, Ashley M; Gunn, Roger N; Holman, Beverley F; Hutton, Brian F; Lee, Sarah; MacNee, William; Mohan, Divya; Parr, David; Subramanian, Deepak; Tal-Singer, Ruth; Thielemans, Kris; van Beek, Edwin J R; Vass, Laurence; Wellen, Jeremy W; Wilkinson, Ian; Wilson, Frederick J

    2017-02-01

    Millions of people are affected by respiratory diseases, leading to a significant health burden globally. Because of the current insufficient knowledge of the underlying mechanisms that lead to the development and progression of respiratory diseases, treatment options remain limited. To overcome this limitation and understand the associated molecular changes, noninvasive imaging techniques such as PET and SPECT have been explored for biomarker development, with (18)F-FDG PET imaging being the most studied. The quantification of pulmonary molecular imaging data remains challenging because of variations in tissue, air, blood, and water fractions within the lungs. The proportions of these components further differ depending on the lung disease. Therefore, different quantification approaches have been proposed to address these variabilities. However, no standardized approach has been developed to date. This article reviews the data evaluating (18)F-FDG PET quantification approaches in lung diseases, focusing on methods to account for variations in lung components and the interpretation of the derived parameters. The diseases reviewed include acute respiratory distress syndrome, chronic obstructive pulmonary disease, and interstitial lung diseases such as idiopathic pulmonary fibrosis. Based on review of prior literature, ongoing research, and discussions among the authors, suggested considerations are presented to assist with the interpretation of the derived parameters from these approaches and the design of future studies.

  3. Cumulative phase delay imaging - A new contrast enhanced ultrasound modality

    SciTech Connect

    Demi, Libertario Sloun, Ruud J. G. van; Mischi, Massimo; Wijkstra, Hessel

    2015-10-28

    Recently, a new acoustic marker for ultrasound contrast agents (UCAs) has been introduced. A cumulative phase delay (CPD) between the second harmonic and fundamental pressure wave field components is in fact observable for ultrasound propagating through UCAs. This phenomenon is absent in the case of tissue nonlinearity and is dependent on insonating pressure and frequency, UCA concentration, and propagation path length through UCAs. In this paper, ultrasound images based on this marker are presented. The ULA-OP research platform, in combination with a LA332 linear array probe (Esaote, Firenze Italy), were used to image a gelatin phantom containing a PVC plate (used as a reflector) and a cylindrical cavity measuring 7 mm in diameter (placed in between the observation point and the PVC plate). The cavity contained a 240 µL/L SonoVueO{sup ®} UCA concentration. Two insonating frequencies (3 MHz and 2.5 MHz) were used to scan the gelatine phantom. A mechanical index MI = 0.07, measured in water at the cavity location with a HGL-0400 hydrophone (Onda, Sunnyvale, CA), was utilized. Processing the ultrasound signals backscattered from the plate, ultrasound images were generated in a tomographic fashion using the filtered back-projection method. As already observed in previous studies, significantly higher CPD values are measured when imaging at a frequency of 2.5 MHz, as compared to imaging at 3 MHz. In conclusion, these results confirm the applicability of the discussed CPD as a marker for contrast imaging. Comparison with standard contrast-enhanced ultrasound imaging modalities will be the focus of future work.

  4. Cumulative phase delay imaging - A new contrast enhanced ultrasound modality

    NASA Astrophysics Data System (ADS)

    Demi, Libertario; van Sloun, Ruud J. G.; Wijkstra, Hessel; Mischi, Massimo

    2015-10-01

    Recently, a new acoustic marker for ultrasound contrast agents (UCAs) has been introduced. A cumulative phase delay (CPD) between the second harmonic and fundamental pressure wave field components is in fact observable for ultrasound propagating through UCAs. This phenomenon is absent in the case of tissue nonlinearity and is dependent on insonating pressure and frequency, UCA concentration, and propagation path length through UCAs. In this paper, ultrasound images based on this marker are presented. The ULA-OP research platform, in combination with a LA332 linear array probe (Esaote, Firenze Italy), were used to image a gelatin phantom containing a PVC plate (used as a reflector) and a cylindrical cavity measuring 7 mm in diameter (placed in between the observation point and the PVC plate). The cavity contained a 240 µL/L SonoVueO® UCA concentration. Two insonating frequencies (3 MHz and 2.5 MHz) were used to scan the gelatine phantom. A mechanical index MI = 0.07, measured in water at the cavity location with a HGL-0400 hydrophone (Onda, Sunnyvale, CA), was utilized. Processing the ultrasound signals backscattered from the plate, ultrasound images were generated in a tomographic fashion using the filtered back-projection method. As already observed in previous studies, significantly higher CPD values are measured when imaging at a frequency of 2.5 MHz, as compared to imaging at 3 MHz. In conclusion, these results confirm the applicability of the discussed CPD as a marker for contrast imaging. Comparison with standard contrast-enhanced ultrasound imaging modalities will be the focus of future work.

  5. Competitive advantage of PET/MRI.

    PubMed

    Jadvar, Hossein; Colletti, Patrick M

    2014-01-01

    Multimodality imaging has made great strides in the imaging evaluation of patients with a variety of diseases. Positron emission tomography/computed tomography (PET/CT) is now established as the imaging modality of choice in many clinical conditions, particularly in oncology. While the initial development of combined PET/magnetic resonance imaging (PET/MRI) was in the preclinical arena, hybrid PET/MR scanners are now available for clinical use. PET/MRI combines the unique features of MRI including excellent soft tissue contrast, diffusion-weighted imaging, dynamic contrast-enhanced imaging, fMRI and other specialized sequences as well as MR spectroscopy with the quantitative physiologic information that is provided by PET. Most evidence for the potential clinical utility of PET/MRI is based on studies performed with side-by-side comparison or software-fused MRI and PET images. Data on distinctive utility of hybrid PET/MRI are rapidly emerging. There are potential competitive advantages of PET/MRI over PET/CT. In general, PET/MRI may be preferred over PET/CT where the unique features of MRI provide more robust imaging evaluation in certain clinical settings. The exact role and potential utility of simultaneous data acquisition in specific research and clinical settings will need to be defined. It may be that simultaneous PET/MRI will be best suited for clinical situations that are disease-specific, organ-specific, related to diseases of the children or in those patients undergoing repeated imaging for whom cumulative radiation dose must be kept as low as reasonably achievable. PET/MRI also offers interesting opportunities for use of dual modality probes. Upon clear definition of clinical utility, other important and practical issues related to business operational model, clinical workflow and reimbursement will also be resolved.

  6. Framework for the construction of a Monte Carlo simulated brain PET-MR image database

    NASA Astrophysics Data System (ADS)

    Thomas, B. A.; Erlandsson, K.; Drobnjak, I.; Pedemonte, S.; Vunckx, K.; Bousse, A.; Reilhac-Laborde, A.; Ourselin, S.; Hutton, B. F.

    2014-01-01

    Simultaneous PET-MR acquisition reduces the possibility of registration mismatch between the two modalities. This facilitates the application of techniques, either during reconstruction or post-reconstruction, that aim to improve the PET resolution by utilising structural information provided by MR. However, in order to validate such methods for brain PET-MR studies it is desirable to evaluate the performance using data where the ground truth is known. In this work, we present a framework for the production of datasets where simulations of both the PET and MR, based on real data, are generated such that reconstruction and post-reconstruction approaches can be fairly compared.

  7. Early Detection of Bone Metastasis in Small Cell Neuroendocrine Carcinoma of the Cervix by 68Ga-DOTATATE PET/CT Imaging.

    PubMed

    Damian, Andres; Lago, Graciela; Rossi, Susana; Alonso, Omar; Engler, Henry

    2017-03-01

    The neuroendocrine small cell carcinoma of the cervix is a rare malignancy that has a poor prognosis due to early lymphatic and hematogenous spread. We herein report a case of a 27- year-old woman who was referred for initial staging of a neuroendocrine small cell carcinoma with previous unremarkable structural imaging. Ga-DOTATATE PET/CT revealed focal uptake at the primary tumor and in a solitary pelvic bone lesion suggestive of metastases that was further confirmed by CT-guided biopsy. Somatostatin receptor PET/CT may be a useful image modality for early detection of metastases to guide treatment in these patients.

  8. Performance evaluation of the microPET P4: a PET system dedicated to animal imaging

    NASA Astrophysics Data System (ADS)

    Tai, Y. C.; Chatziioannou, A.; Siegel, S.; Young, J.; Newport, D.; Goble, R. N.; Nutt, R. E.; Cherry, S. R.

    2001-07-01

    The microPET Primate 4-ring system (P4) is an animal PET tomograph with a 7.8 cm axial extent, a 19 cm diameter transaxial field of view (FOV) and a 22 cm animal port. The system is composed of 168 detector modules, each with an 8×8 array of 2.2×2.2×10 mm3 lutetium oxyorthosilicate crystals, arranged as 32 crystal rings 26 cm in diameter. The detector crystals are coupled to a Hamamatsu R5900-C8 PS-PMT via a 10 cm long optical fibre bundle. The detectors have a timing resolution of 3.2 ns, an average energy resolution of 26%, and an average intrinsic spatial resolution of 1.75 mm. The system operates in 3D mode without inter-plane septa, acquiring data in list mode. The reconstructed image spatial resolution ranges from 1.8 mm at the centre to 3 mm at 4 cm radial offset. The tomograph has a peak system sensitivity of 2.25% at the centre of the FOV with a 250-750 keV energy window. The noise equivalent count rate peaks at 100-290 kcps for representative object sizes. Images from two phantoms and three different types of laboratory animal demonstrate the advantage of the P4 system over the original prototype microPET, including its threefold improvement in sensitivity and a large axial FOV sufficient to image an entire mouse in a single bed position.

  9. Optimizing modelling in iterative image reconstruction for preclinical pinhole PET

    NASA Astrophysics Data System (ADS)

    Goorden, Marlies C.; van Roosmalen, Jarno; van der Have, Frans; Beekman, Freek J.

    2016-05-01

    The recently developed versatile emission computed tomography (VECTor) technology enables high-energy SPECT and simultaneous SPECT and PET of small animals at sub-mm resolutions. VECTor uses dedicated clustered pinhole collimators mounted in a scanner with three stationary large-area NaI(Tl) gamma detectors. Here, we develop and validate dedicated image reconstruction methods that compensate for image degradation by incorporating accurate models for the transport of high-energy annihilation gamma photons. Ray tracing software was used to calculate photon transport through the collimator structures and into the gamma detector. Input to this code are several geometric parameters estimated from system calibration with a scanning 99mTc point source. Effects on reconstructed images of (i) modelling variable depth-of-interaction (DOI) in the detector, (ii) incorporating photon paths that go through multiple pinholes (‘multiple-pinhole paths’ (MPP)), and (iii) including various amounts of point spread function (PSF) tail were evaluated. Imaging 18F in resolution and uniformity phantoms showed that including large parts of PSFs is essential to obtain good contrast-noise characteristics and that DOI modelling is highly effective in removing deformations of small structures, together leading to 0.75 mm resolution PET images of a hot-rod Derenzo phantom. Moreover, MPP modelling reduced the level of background noise. These improvements were also clearly visible in mouse images. Performance of VECTor can thus be significantly improved by accurately modelling annihilation gamma photon transport.

  10. Use of multiple imaging modalities to detect ovarian cancer

    NASA Astrophysics Data System (ADS)

    Kanter, Elizabeth; Walker, Ross; Marion, Sam; Hoyer, Patricia; Barton, Jennifer K.

    2005-04-01

    Ovarian cancer is not a common cancer-approximately 25,000 new cases in 2004-but it is the fifth leading cause of death from cancer in women (over 16,000 in 2004). Little is known about the precursors and early stages of ovarian cancer partially due to the lack of human samples at the early stages. A cohesive model that incorporates ovarian cancer induction into a menopausal rodent would be well suited for comprehensive studies of ovarian cancer. Non-destructive imaging would allow carcinogenesis to be followed. Optical Coherence Tomography (OCT), Optical Coherence Microscopy (OCM) and Light-Induced Fluorescence (LIF) are minimally invasive optical modalities that allow both structural and biochemical changes to be noted. Rat ovaries were exposed to 4-vinylcyclohexene diepoxide (VCD) for 20 days in order to destroy the primordial follicles. Plain sutures and sutures coated with 7,12-dimethylbenz(a)anthracene (DMBA) were implanted in the right ovary, in order to produce epithelial based ovarian cancers (a plain suture was inserted in the control). Rats were sacrificed at 4 weeks and ovaries were harvested and imaged with a combined OCT/LIF system and with the OCM. Histology was preformed on the harvested ovaries and any pathology determined. Two of the ovaries were visually abnormal; the OCT/LIF imaging confirmed these abnormalities. The normal ovary OCM and OCT images show the organized structure of the ovary, the follicles, bursa and corpus lutea are visible. The OCM images show the disorganized structure of one of the abnormal ovaries. Overall this pilot study demonstrated the feasibility of both the animal model and optical imaging.

  11. Simultaneous water activation and glucose metabolic rate imaging with PET

    NASA Astrophysics Data System (ADS)

    Verhaeghe, Jeroen; Reader, Andrew J.

    2013-02-01

    A novel imaging and signal separation strategy is proposed to be able to separate [18F]FDG and multiple [15O]H2O signals from a simultaneously acquired dynamic PET acquisition of the two tracers. The technique is based on the fact that the dynamics of the two tracers are very distinct. By adopting an appropriate bolus injection strategy and by defining tailored sets of basis functions that model either the FDG or water component, it is possible to separate the FDG and water signal. The basis functions are inspired from the spectral analysis description of dynamic PET studies and are defined as the convolution of estimated generating functions (GFs) with a set of decaying exponential functions. The GFs are estimated from the overall measured head curve, while the decaying exponential functions are pre-determined. In this work, the time activity curves (TACs) are modelled post-reconstruction but the model can be incorporated in a global 4D reconstruction strategy. Extensive PET simulation studies are performed considering single [18F]FDG and 6 [15O]H2O bolus injections for a total acquisition time of 75 min. The proposed method is evaluated at multiple noise levels and different parameters were estimated such as [18F]FDG uptake and blood flow estimated from the [15O]H2O component, requiring a full dynamic analysis of the two components, static images of [18F]FDG and the water components as well as [15O]H2O activation. It is shown that the resulting images and parametric values in ROIs are comparable to images obtained from separate imaging, illustrating the feasibility of simultaneous imaging of [18F]FDG and [15O]H2O components. For more information on this article, see medicalphysicsweb.org

  12. Imaging Modalities to Identity Inflammation in an Atherosclerotic Plaque

    PubMed Central

    Goel, Sunny; Miller, Avraham; Agarwal, Chirag; Zakin, Elina; Acholonu, Michael; Gidwani, Umesh; Sharma, Abhishek; Kulbak, Guy; Shani, Jacob; Chen, On

    2015-01-01

    Atherosclerosis is a chronic, progressive, multifocal arterial wall disease caused by local and systemic inflammation responsible for major cardiovascular complications such as myocardial infarction and stroke. With the recent understanding that vulnerable plaque erosion and rupture, with subsequent thrombosis, rather than luminal stenosis, is the underlying cause of acute ischemic events, there has been a shift of focus to understand the mechanisms that make an atherosclerotic plaque unstable or vulnerable to rupture. The presence of inflammation in the atherosclerotic plaque has been considered as one of the initial events which convert a stable plaque into an unstable and vulnerable plaque. This paper systemically reviews the noninvasive and invasive imaging modalities that are currently available to detect this inflammatory process, at least in the intermediate stages, and discusses the ongoing studies that will help us to better understand and identify it at the molecular level. PMID:26798515

  13. Using image synthesis for multi-channel registration of different image modalities.

    PubMed

    Chen, Min; Jog, Amod; Carass, Aaron; Prince, Jerry L

    2015-02-21

    This paper presents a multi-channel approach for performing registration between magnetic resonance (MR) images with different modalities. In general, a multi-channel registration cannot be used when the moving and target images do not have analogous modalities. In this work, we address this limitation by using a random forest regression technique to synthesize the missing modalities from the available ones. This allows a single channel registration between two different modalities to be converted into a multi-channel registration with two mono-modal channels. To validate our approach, two openly available registration algorithms and five cost functions were used to compare the label transfer accuracy of the registration with (and without) our multi-channel synthesis approach. Our results show that the proposed method produced statistically significant improvements in registration accuracy (at an α level of 0.001) for both algorithms and all cost functions when compared to a standard multi-modal registration using the same algorithms with mutual information.

  14. Novel "bi-modal" H2dedpa derivatives for radio- and fluorescence imaging.

    PubMed

    Ramogida, Caterina F; Murphy, Lisa; Cawthray, Jacqueline F; Ross, James D; Adam, Michael J; Orvig, Chris

    2016-09-01

    A novel pyridyl functionalized analog of the promising hexadentate (68)Ga(3+) chelate H2dedpa (N4O2, 1,2-[[6-carboxy-pyridin-2-yl]-methylamine]ethane) was successfully synthesized and characterized. This new bifunctional chelate (BFC) was used to prepare the first proof-of-principle bi-modal H2dedpa derivative for fluorescence and nuclear imaging. Two bi-modal H2dedpa derivatives were prepared: H2dedpa-propylpyr-FITC and H2dedpa-propylpyr-FITC-(N,N'-propyl-2-NI) (FITC=fluorescein, pyr=pyridyl functionalized, NI=nitroimidazole). The ligands possess the strong gallium-coordinating atoms contained within dedpa(2-) that are ideal for radiolabeling with (68)Ga(3+) for positron-emission tomography (PET) imaging, and two fluorophores for optical imaging. In addition, one analog contains two NI moieties for specific entrapment of the tracer in hypoxic cells. These new bi-modal analogs were compared to the native unfunctionalized H2dedpa scaffold to determine the extent to which the addition of pyridyl functionalization would affect metal coordination, and complex stability. The non-radioactive gallium complexes were tested in a 3D tumor spheroid model. The novel pyridyl bis-functionalized H2dedpa ligand, H2dedpa-propylpyr-NH2, was quantitatively radiolabeled with (67)Ga (RCY>99%) under reaction conditions commensurate with unfunctionalized H2dedpa (10min at room temperature) at ligand concentrations as low as 10(-5)M. The resultant (67)Ga-complex withstood transchelation to the in vivo metal-binding competitor apo-transferrin (2h at 37°C, 93% intact), signifying that [Ga(dedpa-propylpyr-NH2)](+) is a kinetically inert complex suitable for in vivo use, but exhibited slightly reduced stability compared to the native [(67)Ga(dedpa)] scaffold (>99% intact). Finally, bi-model fluorescent Ga-dedpa compounds were successfully imaged in a 3D tumor spheroid model. The Ga-dedpa-FITC-NI derivative was specifically localized in the central hypoxic core of the spheroid.

  15. PET/SPECT imaging agents for neurodegenerative diseases

    PubMed Central

    Zhu, Lin; Ploessl, Karl; Kung, Hank F.

    2014-01-01

    Single photon emission computed tomography (SPECT) or positron emission computed tomography (PET) imaging agents for neurodegenerative disease have a significant impact on clinical diagnosis and patient care. The examples of Parkinson’s Disease (PD) and Alzheimer’s Disease (AD) imaging agents described in this paper provide a general view on how imaging agents, ie radioactive drugs, are selected, chemically prepared and applied in humans. Imaging the living human brain can provide unique information on the pathology and progression of neurodegenerative diseases, such as AD and PD. The imaging method will also facilitate preclinical and clinical trials of new drugs offering specific information related to drug binding sites in the brain. In the future, chemists will continue to play important roles in identifying specific targets, synthesizing target-specific probes for screening and ultimately testing them by in vitro and in vivo assays. PMID:24676152

  16. An MR image-guided, voxel-based partial volume correction method for PET images

    PubMed Central

    Wang, Hesheng; Fei, Baowei

    2012-01-01

    Purpose: Partial volume effect in positron emission tomography (PET) can cause incorrect quantification of radiopharmaceutical uptake in functional imaging. A PET partial volume correction method is presented to attenuate partial volume blurring and to yield voxel-based corrected PET images. Methods: By modeling partial volume effect as a convolution of point spread function of the PET scanner, the reconstructed PET images are corrected by iterative deconvolution with an edge-preserving smoothness constraint. The constraint is constructed to restore discontinuities extracted from coregistered MR images but maintains the smoothness in radioactivity distribution. The correction is implemented in a Bayesian deconvolution framework and is solved by a conjugate gradient method. The performance of the method was compared with the geometric transfer matrix (GTM) method on a simulated dataset. The method was evaluated on synthesized brain FDG–PET data and phantom MRI–PET experiments. Results: The true PET activity of objects with a size of greater than the full-width at half maximum of the point spread function has been effectively restored in the simulated data. The partial volume correction method is quantitatively comparable to the GTM method. For synthesized FDG–PET with true activity 0 μci/cc for cerebrospinal fluid (CSF), 228 μci/cc for white matter (WM), and 621 μci/cc for gray matter (GM), the method has improved the radioactivity quantification from 186 ± 16 μci/cc to 30 ± 7 μci/cc in CSF, 317 ± 15 μci/cc to 236 ± 10 μci/cc for WM, 438 ± 4 μci/cc to 592 ± 5 μci/cc for GM. Both visual and quantitative assessments show improvement of partial volume correction in the synthesized and phantom experiments. Conclusions: The partial volume correction method improves the quantification of PET images. The method is comparable to the GTM method but does not need MR image segmentation or prior tracer distribution information. The

  17. Microfluidics for Positron Emission Tomography (PET) Imaging Probe Development

    PubMed Central

    Wang, Ming-Wei; Lin, Wei-Yu; Liu, Kan; Masterman-Smith, Michael; Shen, Clifton Kwang-Fu

    2012-01-01

    Due to increased needs for Positron Emission Tomography (PET) scanning, high demands for a wide variety of radiolabeled compounds will have to be met by exploiting novel radiochemistry and engineering technologies to improve the production and development of PET probes. The application of microfluidic reactors to perform radiosyntheses is currently attracting a great deal of interest because of their potential to deliver many advantages over conventional labeling systems. Microfluidic-based radiochemistry can lead to the use of smaller quantities of precursors, accelerated reaction rates and easier purification processes with greater yield and higher specific activity of desired probes. Several ‘proof-of-principle’ examples, along with basics of device architecture and operation, and potential limitations of each design are discussed here. Along with the concept of radioisotope distribution from centralized cyclotron facilities to individual imaging centers and laboratories (“decentralized model”), an easy-to-use, standalone, flexible, fully-automated radiochemical microfluidic platform can open up to simpler and more cost-effective procedures for molecular imaging using PET. PMID:20643021

  18. Recommendations of the Spanish Societies of Radiation Oncology (SEOR), Nuclear Medicine & Molecular Imaging (SEMNiM), and Medical Physics (SEFM) on 18F-FDG PET-CT for radiotherapy treatment planning

    PubMed Central

    Caballero Perea, Begoña; Villegas, Antonio Cabrera; Rodríguez, José Miguel Delgado; Velloso, María José García; Vicente, Ana María García; Cabrerizo, Carlos Huerga; López, Rosa Morera; Romasanta, Luis Alberto Pérez; Beltrán, Moisés Sáez

    2012-01-01

    Positron emission tomography (PET) with 18F-fluorodeoxyglucose (FDG) is a valuable tool for diagnosing and staging malignant lesions. The fusion of PET and computed tomography (CT) yields images that contain both metabolic and morphological information, which, taken together, have improved the diagnostic precision of PET in oncology. The main imaging modality for planning radiotherapy treatment is CT. However, PET-CT is an emerging modality for use in planning treatments because it allows for more accurate treatment volume definition. The use of PET-CT for treatment planning is highly complex, and protocols and standards for its use are still being developed. It seems probable that PET-CT will eventually replace current CT-based planning methods, but this will require a full understanding of the relevant technical aspects of PET-CT planning. The aim of the present document is to review these technical aspects and to provide recommendations for clinical use of this imaging modality in the radiotherapy planning process. PMID:24377032

  19. Recommendations of the Spanish Societies of Radiation Oncology (SEOR), Nuclear Medicine & Molecular Imaging (SEMNiM), and Medical Physics (SEFM) on (18)F-FDG PET-CT for radiotherapy treatment planning.

    PubMed

    Caballero Perea, Begoña; Villegas, Antonio Cabrera; Rodríguez, José Miguel Delgado; Velloso, María José García; Vicente, Ana María García; Cabrerizo, Carlos Huerga; López, Rosa Morera; Romasanta, Luis Alberto Pérez; Beltrán, Moisés Sáez

    2012-01-01

    Positron emission tomography (PET) with (18)F-fluorodeoxyglucose (FDG) is a valuable tool for diagnosing and staging malignant lesions. The fusion of PET and computed tomography (CT) yields images that contain both metabolic and morphological information, which, taken together, have improved the diagnostic precision of PET in oncology. The main imaging modality for planning radiotherapy treatment is CT. However, PET-CT is an emerging modality for use in planning treatments because it allows for more accurate treatment volume definition. The use of PET-CT for treatment planning is highly complex, and protocols and standards for its use are still being developed. It seems probable that PET-CT will eventually replace current CT-based planning methods, but this will require a full understanding of the relevant technical aspects of PET-CT planning. The aim of the present document is to review these technical aspects and to provide recommendations for clinical use of this imaging modality in the radiotherapy planning process.

  20. Monte Carlo simulation of PET and SPECT imaging of {sup 90}Y

    SciTech Connect

    Takahashi, Akihiko Sasaki, Masayuki; Himuro, Kazuhiko; Yamashita, Yasuo; Komiya, Isao; Baba, Shingo

    2015-04-15

    Purpose: Yittrium-90 ({sup 90}Y) is traditionally thought of as a pure beta emitter, and is used in targeted radionuclide therapy, with imaging performed using bremsstrahlung single-photon emission computed tomography (SPECT). However, because {sup 90}Y also emits positrons through internal pair production with a very small branching ratio, positron emission tomography (PET) imaging is also available. Because of the insufficient image quality of {sup 90}Y bremsstrahlung SPECT, PET imaging has been suggested as an alternative. In this paper, the authors present the Monte Carlo-based simulation–reconstruction framework for {sup 90}Y to comprehensively analyze the PET and SPECT imaging techniques and to quantitatively consider the disadvantages associated with them. Methods: Our PET and SPECT simulation modules were developed using Monte Carlo simulation of Electrons and Photons (MCEP), developed by Dr. S. Uehara. PET code (MCEP-PET) generates a sinogram, and reconstructs the tomography image using a time-of-flight ordered subset expectation maximization (TOF-OSEM) algorithm with attenuation compensation. To evaluate MCEP-PET, simulated results of {sup 18}F PET imaging were compared with the experimental results. The results confirmed that MCEP-PET can simulate the experimental results very well. The SPECT code (MCEP-SPECT) models the collimator and NaI detector system, and generates the projection images and projection data. To save the computational time, the authors adopt the prerecorded {sup 90}Y bremsstrahlung photon data calculated by MCEP. The projection data are also reconstructed using the OSEM algorithm. The authors simulated PET and SPECT images of a water phantom containing six hot spheres filled with different concentrations of {sup 90}Y without background activity. The amount of activity was 163 MBq, with an acquisition time of 40 min. Results: The simulated {sup 90}Y-PET image accurately simulated the experimental results. PET image is visually

  1. Pretargeted PET Imaging Using a Site-Specifically Labeled Immunoconjugate.

    PubMed

    Cook, Brendon E; Adumeau, Pierre; Membreno, Rosemery; Carnazza, Kathryn E; Brand, Christian; Reiner, Thomas; Agnew, Brian J; Lewis, Jason S; Zeglis, Brian M

    2016-08-17

    In recent years, both site-specific bioconjugation techniques and bioorthogonal pretargeting strategies have emerged as exciting technologies with the potential to improve the safety and efficacy of antibody-based nuclear imaging. In the work at hand, we have combined these two approaches to create a pretargeted PET imaging strategy based on the rapid and bioorthogonal inverse electron demand Diels-Alder reaction between a (64)Cu-labeled tetrazine radioligand ((64)Cu-Tz-SarAr) and a site-specifically modified huA33-trans-cyclooctene immunoconjugate ((ss)huA33-PEG12-TCO). A bioconjugation strategy that harnesses enzymatic transformations and strain-promoted azide-alkyne click chemistry was used to site-specifically append PEGylated TCO moieties to the heavy chain glycans of the colorectal cancer-targeting huA33 antibody. Preclinical in vivo validation studies were performed in athymic nude mice bearing A33 antigen-expressing SW1222 human colorectal carcinoma xenografts. To this end, mice were administered (ss)huA33-PEG12-TCO via tail vein injection and-following accumulation intervals of 24 or 48 h-(64)Cu-Tz-SarAr. PET imaging and biodistribution studies reveal that this strategy clearly delineates tumor tissue as early as 1 h post-injection (6.7 ± 1.7%ID/g at 1 h p.i.), producing images with excellent contrast and high tumor-to-background activity concentration ratios (tumor:muscle = 21.5 ± 5.6 at 24 h p.i.). Furthermore, dosimetric calculations illustrate that this pretargeting approach produces only a fraction of the overall effective dose (0.0214 mSv/MBq; 0.079 rem/mCi) of directly labeled radioimmunoconjugates. Ultimately, this method effectively facilitates the high contrast pretargeted PET imaging of colorectal carcinoma using a site-specifically modified immunoconjugate.

  2. Investigation of optimization-based reconstruction with an image-total-variation constraint in PET

    NASA Astrophysics Data System (ADS)

    Zhang, Zheng; Ye, Jinghan; Chen, Buxin; Perkins, Amy E.; Rose, Sean; Sidky, Emil Y.; Kao, Chien-Min; Xia, Dan; Tung, Chi-Hua; Pan, Xiaochuan

    2016-08-01

    Interest remains in reconstruction-algorithm research and development for possible improvement of image quality in current PET imaging and for enabling innovative PET systems to enhance existing, and facilitate new, preclinical and clinical applications. Optimization-based image reconstruction has been demonstrated in recent years of potential utility for CT imaging applications. In this work, we investigate tailoring the optimization-based techniques to image reconstruction for PET systems with standard and non-standard scan configurations. Specifically, given an image-total-variation (TV) constraint, we investigated how the selection of different data divergences and associated parameters impacts the optimization-based reconstruction of PET images. The reconstruction robustness was explored also with respect to different data conditions and activity up-takes of practical relevance. A study was conducted particularly for image reconstruction from data collected by use of a PET configuration with sparsely populated detectors. Overall, the study demonstrates the robustness of the TV-constrained, optimization-based reconstruction for considerably different data conditions in PET imaging, as well as its potential to enable PET configurations with reduced numbers of detectors. Insights gained in the study may be exploited for developing algorithms for PET-image reconstruction and for enabling PET-configuration design of practical usefulness in preclinical and clinical applications.

  3. Imaging of EGFR and EGFR Tyrosine Kinase Overexpression in Tumors by Nuclear Medicine Modalities

    PubMed Central

    Mishani, Eyal; Abourbeh, Galith; Eiblmaier, Martin; Anderson, Carolyn J

    2008-01-01

    Protein tyrosine kinases (PTKs) play a pivotal role in signal transduction pathways and in the development and maintenance of various cancers. They are involved in multiple processes such as transcription, cell cycle progression, proliferation, angiogenesis and inhibition of apoptosis. Among the PTKs, the EGFR is one of the most widely studied and has emerged as a promising key target for the treatment of cancer. Indeed, several drugs directed at this receptor are FDA-approved and many others are at various stages of development. However, thus far, the therapeutic outcome of EGFR-targeted therapy is suboptimal and needs to be refined. Quantitative PET molecular imaging coupled with selective labelled biomarkers may facilitate in vivo EGFR-targeted drug efficacy by noninvasively assessing the expression of EGFR in tumor, guiding dose and regime by measuring target drug binding and receptor occupancy as well as potentially detecting the existence of a primary or secondary mutation leading to either drug interaction or failure of EGFR recognition by the drug. This review describes the attempts to develop labelled EGFR molecular imaging agents that are based either on low molecular weight tyrosine kinase inhibitors or monoclonal antibodies directed to the extracellular binding domain of the receptor to be used in nuclear medicine modalities. PMID:18991714

  4. NEMA NU 4-2008 Comparison of Preclinical PET Imaging Systems

    PubMed Central

    Goertzen, Andrew L.; Bao, Qinan; Bergeron, Mélanie; Blankemeyer, Eric; Blinder, Stephan; Cañadas, Mario; Chatziioannou, Arion F.; Dinelle, Katherine; Elhami, Esmat; Jans, Hans-Sonke; Lage, Eduardo; Lecomte, Roger; Sossi, Vesna; Surti, Suleman; Tai, Yuan-Chuan; Vaquero, Juan José; Vicente, Esther; Williams, Darin A.; Laforest, Richard

    2014-01-01

    The National Electrical Manufacturers Association (NEMA) standard NU 4-2008 for performance measurements of small-animal tomographs was recently published. Before this standard, there were no standard testing procedures for preclinical PET systems, and manufacturers could not provide clear specifications similar to those available for clinical systems under NEMA NU 2-1994 and 2-2001. Consequently, performance evaluation papers used methods that were modified ad hoc from the clinical PET NEMA standard, thus making comparisons between systems difficult. Methods We acquired NEMA NU 4-2008 performance data for a collection of commercial animal PET systems manufactured since 2000: micro- PET P4, microPET R4, microPET Focus 120, microPET Focus 220, Inveon, ClearPET, Mosaic HP, Argus (formerly eXplore Vista), VrPET, LabPET 8, and LabPET 12. The data included spatial resolution, counting-rate performance, scatter fraction, sensitivity, and image quality and were acquired using settings for routine PET. Results The data showed a steady improvement in system performance for newer systems as compared with first-generation systems, with notable improvements in spatial resolution and sensitivity. Conclusion Variation in system design makes direct comparisons between systems from different vendors difficult. When considering the results from NEMA testing, one must also consider the suitability of the PET system for the specific imaging task at hand. PMID:22699999

  5. Precise diagnosis in different scenarios using photoacoustic and fluorescence imaging with dual-modality nanoparticles

    NASA Astrophysics Data System (ADS)

    Peng, Dong; Du, Yang; Shi, Yiwen; Mao, Duo; Jia, Xiaohua; Li, Hui; Zhu, Yukun; Wang, Kun; Tian, Jie

    2016-07-01

    Photoacoustic imaging and fluorescence molecular imaging are emerging as important research tools for biomedical studies. Photoacoustic imaging offers both strong optical absorption contrast and high ultrasonic resolution, and fluorescence molecular imaging provides excellent superficial resolution, high sensitivity, high throughput, and the ability for real-time imaging. Therefore, combining the imaging information of both modalities can provide comprehensive in vivo physiological and pathological information. However, currently there are limited probes available that can realize both fluorescence and photoacoustic imaging, and advanced biomedical applications for applying this dual-modality imaging approach remain underexplored. In this study, we developed a dual-modality photoacoustic-fluorescence imaging nanoprobe, ICG-loaded Au@SiO2, which was uniquely designed, consisting of gold nanorod cores and indocyanine green with silica shell spacer layers to overcome fluorophore quenching. This nanoprobe was examined by both PAI and FMI for in vivo imaging on tumor and ischemia mouse models. Our results demonstrated that the nanoparticles can specifically accumulate at the tumor and ischemic areas and be detected by both imaging modalities. Moreover, this dual-modality imaging strategy exhibited superior advantages for a precise diagnosis in different scenarios. The new nanoprobe with the dual-modality imaging approach holds great potential for diagnosis and stage classification of tumor and ischemia related diseases.Photoacoustic imaging and fluorescence molecular imaging are emerging as important research tools for biomedical studies. Photoacoustic imaging offers both strong optical absorption contrast and high ultrasonic resolution, and fluorescence molecular imaging provides excellent superficial resolution, high sensitivity, high throughput, and the ability for real-time imaging. Therefore, combining the imaging information of both modalities can provide

  6. Bimodal Thrombus Imaging: Simultaneous PET/MR Imaging with a Fibrin-targeted Dual PET/MR Probe—Feasibility Study in Rat Model

    PubMed Central

    Uppal, Ritika; Catana, Ciprian; Ay, Ilknur; Benner, Thomas; Sorensen, A. Gregory

    2011-01-01

    Purpose: To image thrombus by using magnetic resonance (MR) imaging and positron emission tomography (PET) simultaneously in a rat arterial thrombus model with a dual PET/MR probe. Materials and Methods: Animal studies were approved by the institutional animal use committee. A dual PET/MR probe was synthesized by means of partial exchange of gadolinium for copper 64 (64Cu) in the fibrin-targeted MR probe EP-2104R. A preformed 25-mm thrombus was injected into the right internal carotid artery of a rat. Imaging was performed with a clinical 3.0-T MR imager with an MR-compatible human PET imager. Rats (n = 5) were imaged prior to and after systemic administration of the dual probe by using simultaneous PET/MR. The organ distribution of 64Cu and gadolinium was determined ex vivo (n = 8), 2 hours after injection by using well counting and inductively coupled plasma mass spectrometry, respectively. Signal intensity ratios (SIRs) between the thrombus-containing and contralateral vessel were computed from PET images and MR data before and after probe administration. Results: The dual probe was synthesized with greater than 98% radiochemical purity. Thrombus enhancement was observed in all five animals at both MR (SIR[postprobe]/SIR[preprobe] = 1.71 ± 0.35, P = .0053) and PET (SIR = 1.85 ± 0.48, P = .0087) after injection of the dual PET/MR probe. Ex vivo analysis at 2 hours after injection showed the highest 64Cu and gadolinium concentrations, after the excretory organs (kidney and liver), to be in the thrombus. Conclusion: A fibrin-targeted dual PET/MR probe enables simultaneous, direct MR and PET imaging of thrombus. © RSNA, 2010 PMID:21177389

  7. PET imaging of dopamine receptors in MPTP-induced parkinsonism

    SciTech Connect

    Larson, S.M.; DiChiro, G.; Burns, R.S.; Dannals, R.F.; Kopin, I.J.; Brooks, R.A.; Kessler, R.M.; Wagner, R.F.; Eckelman, W.C.; Margolin, R.A.

    1984-01-01

    MPTP(N-methyl-4-phenyl-1,2,3,6-tetrahydropyridine) induces parkinsonism in animals and man by selectively destroying dopaminergic neurons in the pars compacta of the substantia nigra. The postsynaptic neurons (and presumably the dopamine receptors) are intact. The authors have imaged dopamine receptors in a patient with MPTP induced parkinsonism, using /sup 11/CMS (3-N(/sup 11/C) methylspiperone. Seven and 9 mCi's, respectively, were injected at one week intervals while the patient was first off, and then on, L-dopa. As measured by NeuroPET (NIH), putamen to cerebellum concentration ratios rose progressively to 5.5:1, by 90 min. after injection. At this time the concentration of /sup 11/CMS was 10 picomole/cc (off L-dopa), and 14 picomole/cc (on L-dopa). The Duvoisin scale was used to assess the severity of the patient's parkinsonism immediately prior and at the end of PET imaging. On both occasions, despite the small mass amount of /sup 11/CMS injected, (1.1 g/kg), a transient worsening of symptoms was seen. The effect of L-Dopa was almost completely reversed by the /sup 11/CMS. In contrast, off L-Dopa the patients severe basal state was worsened only slightly. The PET scans suggested that dopamine receptors are not reduced in MPTP-induced parkinsonism. The findings were consistent with the hypotheses that PET may identify patients who will benefit from L-Dopa, and that expression of parkinsonian symptoms reflects desaturation of dopamine receptors in striatum.

  8. MR-based motion correction for PET imaging using wired active MR microcoils in simultaneous PET-MR: Phantom study

    SciTech Connect

    Huang, Chuan; Brady, Thomas J.; El Fakhri, Georges; Ouyang, Jinsong; Ackerman, Jerome L.; Petibon, Yoann

    2014-04-15

    Purpose: Artifacts caused by head motion present a major challenge in brain positron emission tomography (PET) imaging. The authors investigated the feasibility of using wired active MR microcoils to track head motion and incorporate the measured rigid motion fields into iterative PET reconstruction. Methods: Several wired active MR microcoils and a dedicated MR coil-tracking sequence were developed. The microcoils were attached to the outer surface of an anthropomorphic{sup 18}F-filled Hoffman phantom to mimic a brain PET scan. Complex rotation/translation motion of the phantom was induced by a balloon, which was connected to a ventilator. PET list-mode and MR tracking data were acquired simultaneously on a PET-MR scanner. The acquired dynamic PET data were reconstructed iteratively with and without motion correction. Additionally, static phantom data were acquired and used as the gold standard. Results: Motion artifacts in PET images were effectively removed by wired active MR microcoil based motion correction. Motion correction yielded an activity concentration bias ranging from −0.6% to 3.4% as compared to a bias ranging from −25.0% to 16.6% if no motion correction was applied. The contrast recovery values were improved by 37%–156% with motion correction as compared to no motion correction. The image correlation (mean ± standard deviation) between the motion corrected (uncorrected) images of 20 independent noise realizations and static reference was R{sup 2} = 0.978 ± 0.007 (0.588 ± 0.010, respectively). Conclusions: Wired active MR microcoil based motion correction significantly improves brain PET quantitative accuracy and image contrast.

  9. Comparison between two super-resolution implementations in PET imaging.

    PubMed

    Chang, Guoping; Pan, Tinsu; Qiao, Feng; Clark, John W; Mawlawi, Osama R

    2009-04-01

    Super-resolution (SR) techniques are used in PET imaging to generate a high-resolution image by combining multiple low-resolution images that have been acquired from different points of view (POV). In this article, the authors propose a novel implementation of the SR technique whereby the required multiple low-resolution images are generated by shifting the reconstruction pixel grid during the image reconstruction process rather than being acquired from different POVs. The objective of this article is to compare the performances of the two SR implementations using theoretical and experimental studies. A mathematical framework is first provided to support the hypothesis that the two SR implementations have similar performance in current PET/CT scanners that use block detectors. Based on this framework, a simulation study, a point source study, and a NEMA/IEC phantom study were conducted to compare the performance of these two SR implementations with respect to contrast, resolution, noise, and SNR. For reference purposes, a comparison with a native reconstruction (NR) image using a high-resolution pixel grid was also performed. The mathematical framework showed that the two SR implementations are expected to achieve similar contrast and resolution but different noise contents. These results were confirmed by the simulation and experimental studies. The simulation study showed that the two SR implementations have an average contrast difference of 2.3%, while the point source study showed that their average differences in contrast and resolution were 0.5% and 1.2%, respectively. Comparisons between the SR and NR images for the point source study showed that the NR image exhibited averages of 30% and 8% lower contrast and resolution, respectively. The NEMA/IEC phantom study showed that the three images (two SR and NR) exhibited different noise structures. The SNR of the new SR implementation was, on average, 21.5% lower than the original implementation largely due to an

  10. Solitary sternal metastasis from hepatocellular carcinoma detected by F-18 FDG PET/CT.

    PubMed

    Kamaleshwaran, Koramadai Karuppusamy; Kashyap, Raghava; Bhattacharya, Anish; Mittal, Bhagwant Rai

    2013-01-01

    Fluorine-18 fluoro-deoxy-glucose positron emission tomography (F-18 FDG PET) is not sensitive modality for the diagnosis of primary hepatocellular carcinoma (HCC). However, FDG-PET imaging may be useful in the identification of extrahepatic metastases. We report an interesting image of HCC with solitary metastasis to sternum detected by F-18 FDG PET/CT.

  11. RGD-based PET tracers for imaging receptor integrin αv β3 expression.

    PubMed

    Cai, Hancheng; Conti, Peter S

    2013-05-15

    Positron emission tomography (PET) imaging of receptor integrin αv β3 expression may play a key role in the early detection of cancer and cardiovascular diseases, monitoring disease progression, evaluating therapeutic response, and aiding anti-angiogenic drugs discovery and development. The last decade has seen the development of new PET tracers for in vivo imaging of integrin αv β3 expression along with advances in PET chemistry. In this review, we will focus on the radiochemistry development of PET tracers based on arginine-glycine-aspartic acid (RGD) peptide, present an overview of general strategies for preparing RGD-based PET tracers, and review the recent advances in preparations of (18) F-labeled, (64) Cu-labeled, and (68) Ga-labeled RGD tracers, RGD-based PET multivalent probes, and RGD-based PET multimodality probes for imaging receptor integrin αv β3 expression.

  12. [Situation of supply and boom of PET imaging: what is the future for technetium-99m in nuclear medicine?].

    PubMed

    Maia, S; Ayachi Hatit, N; Paycha, F

    2011-05-01

    Molecular imaging has shown its interest in the diagnosis, staging and therapy monitoring of many diseases, especially in the field of cancer. This imaging modality can detect non-invasively early molecular changes specific to these diseases. Its expansion includes two aspects linked firstly with the advanced techniques of imaging modalities and secondly with the development of tracers as radio pharmaceuticals for imaging new molecular targets. Technetium-99m ((99m)Tc), because of its physical characteristics, its widespread availability and low cost, is the most used radionuclide in molecular imaging with the technique of single photon emission computed tomography (SPECT). Nevertheless, the current difficulty concerning the supply and the great interest of Positron Emission Tomography (PET), the "competitor" imaging modality-using molecules labelled with fluorine-18 ((18)F), legitimates the question about the future of (99m)Tc, its supremacy and the emergence of new tracer labelled with (99m)Tc. Focusing on the actual and future supply situation, the place of SPECT imaging in nuclear medicine, as well as the development of new molecules labelled with (99m)Tc is necessary to show that this radionuclide will remain essential for the speciality in the next years.

  13. Iodine-124 as a label for pharmacological PET imaging.

    PubMed

    Belov, Vasily V; Bonab, Ali A; Fischman, Alan J; Heartlein, Michael; Calias, Pericles; Papisov, Mikhail I

    2011-06-06

    With the growing number of biotechnology products and drug delivery systems entering preclinical and clinical studies, pharmacological imaging studies with PET play an increasingly significant role. Such studies often require investigation of slow and complex pharmacokinetics (PK). This suggests labeling of the drug candidate with radionuclides that have long physical half-lives. Among the currently available PET positron emitters, ¹²⁴I has the longest physical half-life (4.2 days). This, combined with the well-investigated behavior of iodine in vivo, makes ¹²⁴I very attractive for pharmacological studies. However, the high energy of the positrons emitted by ¹²⁴I and the presence of single photons in the ¹²⁴I emission can potentially introduce limitations in the quantitative analysis of the images. The objective of this research was to determine whether the use of ¹²⁴I as a PET label provides data quality suitable for PK studies. The study was carried out using MicroPET P4 scanner (Siemens/Concorde Microsystems). Spatial resolution, count-rate performance, sensitivity and scatter fraction were measured using a line source and a cylindrical phantom. Model animal studies in rats and cynomolgus monkeys were carried out using human recombinant proteins. The proteins were labeled with ¹²⁴I, up to 185 MBq/mg. The transaxial and axial spatial resolutions in the center of the camera were satisfactory and higher for OSEM3D/MAP than FORE-2DFBP (FWHM 2.52 vs 3.31 mm, and 3.10 vs 3.69 mm). Linearity of the true coincidence count-rate was observed up to 44 MBq. Animal studies demonstrated excellent delineation and resolution of even very small organs. At optimal doses, 2-10 MBq per animal for rodents and 4-10 MBq per kg of body weight for larger animals, the quality of numerical data was appropriate for PK analysis in all experimental timeframes from minutes (dynamic studies) to 10 days. Overall, the data suggest that ¹²⁴I is an excellent label for

  14. PET Radiotracers for Imaging the Proliferative Status of Solid Tumors

    PubMed Central

    Mach, Robert H.; Dehdashti, Farrokh; Wheeler, Kenneth T.

    2009-01-01

    Synopsis Two different strategies have been developed for imaging the proliferative status of solid tumors with the functional imaging technique, Positron Emission Tomography (PET). The first strategy uses carbon-11 labeled thymidine and/or, more recently, fluorine-18 labeled thymidine analogs. These agents are a substrate for the enzyme thymidine kinase-1 (TK-1) and provide a pulse label of the number of cells in S phase. The second method for imaging the proliferative status of a tumor uses radiolabeled ligands that bind to the sigma-2 receptor which has a 10-fold higher density in proliferating (P) tumor cells versus quiescent (Q) tumor cells. This article compares and contrasts the two different strategies for imaging the proliferative status of solid tumors, and describes the strengths and weaknesses of each approach. PMID:20046891

  15. Physiological imaging with PET and SPECT in Dementia

    SciTech Connect

    Jagust, W.J. . Dept. of Neurology Lawrence Berkeley Lab., CA )

    1989-10-01

    Dementia is a medical problem of increasingly obvious importance. The most common cause of dementia, Alzheimer's disease (AD) accounts for at least 50% of all cases of dementia, with multi-infarct dementia the next most common cause of the syndrome. While the accuracy of diagnosis of AD may range from 80 to 90%, there is currently no laboratory test to confirm the diagnosis. Functional imaging techniques such as positron emission tomography (PET) and single photon emission computed tomography (SPECT) offer diagnostic advantages since brain function is unequivocally disturbed in all dementing illnesses. Both PET and SPECT have been utilized in the study of dementia. While both techniques rely on principles of emission tomography to produce three dimensional maps of injected radiotracers, the differences between positron and single photon emission have important consequences for the practical applications of the two procedures. This briefly reviews the technical differences between PET and SPECT, and discusses how both techniques have been used in our laboratory to elucidate the pathophysiology of dementia. 32 refs., 2 figs.

  16. Detector Technologies for Sub-500um High-Sensitivity PET Imaging via a Novel PET Insert Approach

    SciTech Connect

    Tai, Yuan-Chuan

    2011-12-21

    The objective of this project was to develop detector technologies that would enable an ultrahigh resolution Virtual Pinhole (VP) PET insert device to provide sub-500 um resolution high-sensitivity PET imaging of a mouse in the future. To achieve this goal, we proposed to develop and characterize finely pixellated cadmium zinc telluride (CZT) detectors and the associated readout electronics with the following specific aims: 1. Develop pixellated CZT detectors with 350um pitches using 2-5 mm substrates; characterize their spatial, energy and timing performance through experiments; and optimize the anode design with steering grid if found necessary. 2. Develop a high-bandwidth readout system using a novel ASIC that can be directly bonded to CZT detectors with 2048 anodes of 350um pitches; optimize its overall performance for VP-PET applications considering the tradeoffs between spatial resolution (in 3D), count rate capability, timing and energy resolutions. 3. Evaluate the performance of a VP-PET insert based on the proposed detector technology through Monte Carlo simulation and experimental validation. Overall, we have completed all three specific aims and demonstrated that pixelated CZT detectors of 350um pitches, combined with VP-PET geometry, can provide PET image resolution of ~460 um FWHM for small animal imaging applications.

  17. Comparison of Imaging Characteristics of (124)I PET for Determination of Optimal Energy Window on the Siemens Inveon PET.

    PubMed

    Yu, A Ram; Kim, Hee-Joung; Lim, Sang Moo; Kim, Jin Su

    2016-01-01

    Purpose. (124)I has a half-life of 4.2 days, which makes it suitable for imaging over several days over its uptake and washout phases. However, it has a low positron branching ratio (23%), because of prompt gamma coincidence due to high-energy γ-photons (602 to 1,691 keV), which are emitted in cascade with positrons. Methods. In this study, we investigated the optimal PET energy window for (124)I PET based on image characteristics of reconstructed PET. Image characteristics such as nonuniformities, recovery coefficients (RCs), and the spillover ratios (SORs) of (124)I were measured as described in NEMA NU 4-2008 standards. Results. The maximum and minimum prompt gamma coincidence fraction (PGF) were 33% and 2% in 350~800 and 400~590 keV, respectively. The difference between best and worst uniformity in the various energy windows was less than 1%. The lowest SORs of (124)I were obtained at 350~750 keV in nonradioactive water compartment. Conclusion. Optimal energy window should be determined based on image characteristics. Our developed correction method would be useful for the correction of high-energy prompt gamma photon in (124)I PET. In terms of the image quality of (124)I PET, our findings indicate that an energy window of 350~750 keV would be optimal.

  18. Imaging performance of LabPET APD-based digital PET scanners for pre-clinical research

    NASA Astrophysics Data System (ADS)

    Bergeron, Mélanie; Cadorette, Jules; Tétrault, Marc-André; Beaudoin, Jean-François; Leroux, Jean-Daniel; Fontaine, Réjean; Lecomte, Roger

    2014-02-01

    The LabPET is an avalanche photodiode (APD) based digital PET scanner with quasi-individual detector read-out and highly parallel electronic architecture for high-performance in vivo molecular imaging of small animals. The scanner is based on LYSO and LGSO scintillation crystals (2×2×12/14 mm3), assembled side-by-side in phoswich pairs read out by an APD. High spatial resolution is achieved through the individual and independent read-out of an individual APD detector for recording impinging annihilation photons. The LabPET exists in three versions, LabPET4 (3.75 cm axial length), LabPET8 (7.5 cm axial length) and LabPET12 (11.4 cm axial length). This paper focuses on the systematic characterization of the three LabPET versions using two different energy window settings to implement a high-efficiency mode (250-650 keV) and a high-resolution mode (350-650 keV) in the most suitable operating conditions. Prior to measurements, a global timing alignment of the scanners and optimization of the APD operating bias have been carried out. Characteristics such as spatial resolution, absolute sensitivity, count rate performance and image quality have been thoroughly investigated following the NEMA NU 4-2008 protocol. Phantom and small animal images were acquired to assess the scanners' suitability for the most demanding imaging tasks in preclinical biomedical research. The three systems achieve the same radial FBP spatial resolution at 5 mm from the field-of-view center: 1.65/3.40 mm (FWHM/FWTM) for an energy threshold of 250 keV and 1.51/2.97 mm for an energy threshold of 350 keV. The absolute sensitivity for an energy window of 250-650 keV is 1.4%/2.6%/4.3% for LabPET4/8/12, respectively. The best count rate performance peaking at 362 kcps is achieved by the LabPET12 with an energy window of 250-650 keV and a mouse phantom (2.5 cm diameter) at an activity of 2.4 MBq ml-1. With the same phantom, the scatter fraction for all scanners is about 17% for an energy threshold of

  19. PET Imaging and Biodistribution of Silicon Quantum Dots in Mice

    PubMed Central

    2011-01-01

    Investigation of nanomaterial disposition and fate in the body is critical before such material can be translated into clinical application. Herein a new macrocyclic ligand−64Cu2+ complex was synthesized and used to label dextran-coated silicon quantum dots (QD), with an average hydrodynamic diameter of 15.1 ± 7.6 nm. The chelate showed exceptional stability, demonstrated by no loss radiolabel under a ligand competition reaction with EDTA. The QDs’ biodistribution in mice was quantitatively evaluated by in vivo positron emission tomography (PET) imaging and ex vivo gamma counting. Results showed that they were excreted via renal filtration shortly postinjection and also accumulated in the liver. PMID:21546997

  20. Segmentation of dynamic PET images with kinetic spectral clustering

    NASA Astrophysics Data System (ADS)

    Mouysset, S.; Zbib, H.; Stute, S.; Girault, J. M.; Charara, J.; Noailles, J.; Chalon, S.; Buvat, I.; Tauber, C.

    2013-10-01

    Segmentation is often required for the analysis of dynamic positron emission tomography (PET) images. However, noise and low spatial resolution make it a difficult task and several supervised and unsupervised methods have been proposed in the literature to perform the segmentation based on semi-automatic clustering of the time activity curves of voxels. In this paper we propose a new method based on spectral clustering that does not require any prior information on the shape of clusters in the space in which they are identified. In our approach, the p-dimensional data, where p is the number of time frames, is first mapped into a high dimensional space and then clustering is performed in a low-dimensional space of the Laplacian matrix. An estimation of the bounds for the scale parameter involved in the spectral clustering is derived. The method is assessed using dynamic brain PET images simulated with GATE and results on real images are presented. We demonstrate the usefulness of the method and its superior performance over three other clustering methods from the literature. The proposed approach appears as a promising pre-processing tool before parametric map calculation or ROI-based quantification tasks.

  1. Role of Artificial Intelligence Techniques (Automatic Classifiers) in Molecular Imaging Modalities in Neurodegenerative Diseases.

    PubMed

    Cascianelli, Silvia; Scialpi, Michele; Amici, Serena; Forini, Nevio; Minestrini, Matteo; Fravolini, Mario Luca; Sinzinger, Helmut; Schillaci, Orazio; Palumbo, Barbara

    2017-01-01

    Artificial Intelligence (AI) is a very active Computer Science research field aiming to develop systems that mimic human intelligence and is helpful in many human activities, including Medicine. In this review we presented some examples of the exploiting of AI techniques, in particular automatic classifiers such as Artificial Neural Network (ANN), Support Vector Machine (SVM), Classification Tree (ClT) and ensemble methods like Random Forest (RF), able to analyze findings obtained by positron emission tomography (PET) or single-photon emission tomography (SPECT) scans of patients with Neurodegenerative Diseases, in particular Alzheimer's Disease. We also focused our attention on techniques applied in order to preprocess data and reduce their dimensionality via feature selection or projection in a more representative domain (Principal Component Analysis - PCA - or Partial Least Squares - PLS - are examples of such methods); this is a crucial step while dealing with medical data, since it is necessary to compress patient information and retain only the most useful in order to discriminate subjects into normal and pathological classes. Main literature papers on the application of these techniques to classify patients with neurodegenerative disease extracting data from molecular imaging modalities are reported, showing that the increasing development of computer aided diagnosis systems is very promising to contribute to the diagnostic process.

  2. PET imaging of neurogenic activity in the adult brain: Toward in vivo imaging of human neurogenesis.

    PubMed

    Tamura, Yasuhisa; Kataoka, Yosky

    2017-01-01

    Neural stem cells are present in 2 neurogenic regions, the subventricular zone (SVZ) and the subgranular zone (SGZ) of the hippocampal dentate gyrus (DG), and continue to generate new neurons throughout life. Adult hippocampal neurogenesis is linked to a variety of psychiatric disorders such as depression and anxiety, and to the therapeutic effects of antidepressants, as well as learning and memory. In vivo imaging for hippocampal neurogenic activity may be used to diagnose psychiatric disorders and evaluate the therapeutic efficacy of antidepressants. However, these imaging techniques remain to be established until now. Recently, we established a quantitative positron emission tomography (PET) imaging technique for neurogenic activity in the adult brain with 3'-deoxy-3'-[(18)F]fluoro-L-thymidine ([(18)F]FLT) and probenecid, a drug transporter inhibitor in blood-brain barrier. Moreover, we showed that this PET imaging technique can monitor alterations in neurogenic activity in the hippocampus of adult rats with depression and following treatment with an antidepressant. This PET imaging method may assist in diagnosing depression and in monitoring the therapeutic efficacy of antidepressants. In this commentary, we discuss the possibility of in vivo PET imaging for neurogenic activity in adult non-human primates and humans.

  3. Development of PET imaging-based dose-painting prescriptions

    NASA Astrophysics Data System (ADS)

    Bowen, Stephen R.

    Historically, prescriptions in radiation therapy are based on physician experience drawn from the results of extensive clinical trials in order to establish standard-of-care guidelines. The doses of radiation are generally uniform across target volumes to reflect a fixed level of local neoplastic disease control of the population mean. However, inter-patient and intra-tumor variation in response to uniform doses can result in diminished tumor control and poor clinical outcome for certain patients. Recent research endeavors are emphasizing the need to individualize prescriptions by incorporating patient-specific biological markers with prognostic and predictive value. Quantitative imaging with positron emission tomography (PET) of tumor glucose metabolism, cell proliferation, and hypoxia has been suggested as a sensitive and specific technique to tailor patient prescriptions in a manner that may significantly improve clinical outcome. The concept of prescribing and delivering non-uniform dose based on molecular imaging, termed dose painting, hinges on the establishment of a dose-response relationship at the image voxel scale that optimizes a particular clinical endpoint. This doctoral thesis presented two methods of defining dose-painting prescriptions based on PET imaging: the first was a heuristic model derivation of hypoxia dose-painting prescriptions in head-and-neck cancer patients; the second was an empirical imaging surrogate endpoint derivation of prescriptions in veterinary sinonasal cancer patients. The clinical implementation of these dose painting prescriptions was investigated, which emphasized treatment planning and delivery solutions. Lastly, a summary and discussion of the future of dose painting to forge links between tumor biology and clinical outcome was presented. The compelling dose painting concept is fast becoming a clinical reality that may positively impact cancer patient lives.

  4. (68)Ga-labeled 3PRGD2 for dual PET and Cerenkov luminescence imaging of orthotopic human glioblastoma.

    PubMed

    Fan, Di; Zhang, Xin; Zhong, Lijun; Liu, Xujie; Sun, Yi; Zhao, Huiyun; Jia, Bing; Liu, Zhaofei; Zhu, Zhaohui; Shi, Jiyun; Wang, Fan

    2015-06-17

    β-Emitters can produce Cerenkov radiation that is detectable by Cerenkov luminescence imaging (CLI), allowing the combination of PET and CLI with one radiotracer for both tumor diagnosis and visual guidance during surgery. Recently, the clinical feasibility of CLI with the established therapeutic reagent Na(131)I and the PET tracer (18)F-FDG was demonstrated. (68)Ga possesses a higher Cerenkov light output than (18)F and (131)I, which would result in higher sensitivity for CLI and improve the outcome of CLI in clinical applications. However, the research on (68)Ga-based tumor-specific tracers for CLI is limited. In this study, we examined the use of (68)Ga-radiolabeled DOTA-3PRGD2 ((68)Ga-3PRGD2) for dual PET and CLI of orthotopic U87MG human glioblastoma. For this purpose, the Cerenkov efficiencies of (68)Ga and (18)F were measured with the IVIS Spectrum system (PerkinElmer, USA). The CLI signal intensity of (68)Ga was 15 times stronger than that of (18)F. PET and CLI of (68)Ga-3PRGD2 were performed in U87MG human glioblastoma xenografts. Both PET and CLI revealed a remarkable accumulation of (68)Ga-3PRGD2 in the U87MG human glioblastoma xenografts at 1 h p.i. with an extremely low background in the brain when compared with (18)F-FDG. Furthermore, (68)Ga-3PRGD2 was used for dual PET and CLI of orthotopic human glioblastoma. The orthotopic human glioblastoma was clearly visualized by both imaging modalities. In addition, the biodistribution of (68)Ga-3PRGD2 was assessed in normal mice to estimate the radiation dosimetry. The whole-body effective dose is 20.1 ± 3.3 μSv/MBq, which is equal to 3.7 mSv per whole-body PET scan with a 5 mCi injection dose. Thus, (68)Ga-3PRGD2 involves less radiation exposure in patients when compared with (18)F-FDG (7.0 mSv). The use of (68)Ga-3PRGD2 in dual PET and CLI shows great promise for tumor diagnosis and image-guided surgery.

  5. Gastrin-releasing Peptide Receptor Imaging in Breast Cancer Using the Receptor Antagonist 68Ga-RM2 And PET

    PubMed Central

    Stoykow, Christian; Erbes, Thalia; Maecke, Helmut R; Bulla, Stefan; Bartholomä, Mark; Mayer, Sebastian; Drendel, Vanessa; Bronsert, Peter; Werner, Martin; Gitsch, Gerald; Weber, Wolfgang A; Stickeler, Elmar; Meyer, Philipp T

    2016-01-01

    Introduction: The gastrin-releasing peptide receptor (GRPR) is overexpressed in breast cancer. The present study evaluates GRPR imaging as a novel imaging modality in breast cancer by employing positron emission tomography (PET) and the GRPR antagonist 68Ga-RM2. Methods: Fifteen female patients with biopsy confirmed primary breast carcinoma (3 bilateral tumors; median clinical stage IIB) underwent 68Ga-RM2-PET/CT for pretreatment staging. In vivo tumor uptake of 68Ga-RM2 was correlated with estrogen (ER) and progesterone (PR) receptor expression, HER2/neu status and MIB-1 proliferation index in breast core biopsy specimens. Results: 13/18 tumors demonstrated strongly increased 68Ga-RM2 uptake compared to normal breast tissue (defined as PET-positive). All PET-positive primary tumors were ER- and PR-positive (13/13) in contrast to only 1/5 PET-negative tumors. Mean SUVMAX of ER-positive tumors was 10.6±6.0 compared to 2.3±1.0 in ER-negative tumors (p=0.016). In a multivariate analysis including ER, PR, HER2/neu and MIB-1, only ER expression predicted 68Ga-RM2 uptake (model: r2=0.55, p=0.025). Normal breast tissue showed inter- and intraindividually variable, moderate GRPR binding (SUVMAX 2.3±1.0), while physiological uptake of other organs was considerably less except pancreas. Of note, 68Ga-RM2-PET/CT detected internal mammary lymph nodes with high 68Ga-RM2 uptake (n=8), a contralateral axillary lymph node metastasis (verified by biopsy) and bone metastases (n=1; not detected by bone scan and CT). Conclusion: Our study demonstrates that 68Ga-RM2-PET/CT is a promising imaging method in ER-positive breast cancer. In vivo GRPR binding assessed by 68Ga-RM2-PET/CT correlated with ER expression in primary tumors of untreated patients. PMID:27446498

  6. PET imaging predicts future body weight and cocaine preference

    SciTech Connect

    Michaelides M.; Wang G.; Michaelides M.; Thanos P.K. Kim R.; Cho J.; Ananth M.; Wang G.-J.; Volkow N.D.

    2011-08-28

    Deficits in dopamine D2/D3 receptor (D2R/D3R) binding availability using PET imaging have been reported in obese humans and rodents. Similar deficits have been reported in cocaine-addicts and cocaine-exposed primates. We found that D2R/D3R binding availability negatively correlated with measures of body weight at the time of scan (ventral striatum), at 1 (ventral striatum) and 2 months (dorsal and ventral striatum) post scan in rats. Cocaine preference was negatively correlated with D2R/D3R binding availability 2 months (ventral striatum) post scan. Our findings suggest that inherent deficits in striatal D2R/D3R signaling are related to obesity and drug addiction susceptibility and that ventral and dorsal striatum serve dissociable roles in maintaining weight gain and cocaine preference. Measuring D2R/D3R binding availability provides a way for assessing susceptibility to weight gain and cocaine abuse in rodents and given the translational nature of PET imaging, potentially primates and humans.

  7. How Can New Imaging Modalities Help in the Practice of Radiology?

    PubMed Central

    Pirimoglu, Berhan; Sade, Recep; Ogul, Hayri; Kantarci, Mecit; Eren, Suat; Levent, Akın

    2016-01-01

    The purpose of this article was to provide an up-to-date review on the spectrum of new imaging applications in the practice of radiology. New imaging techniques have been developed with the objective of obtaining structural and functional analyses of different body systems. Recently, new imaging modalities have aroused the interest of many researchers who are studying the applicability of these modalities in the evaluation of different organs and diseases. In this review article, we present the efficiency and utilization of current imaging modalities in daily radiological practice. PMID:28149149

  8. How Can New Imaging Modalities Help in the Practice of Radiology?

    PubMed

    Pirimoglu, Berhan; Sade, Recep; Ogul, Hayri; Kantarci, Mecit; Eren, Suat; Levent, Akın

    2016-10-01

    The purpose of this article was to provide an up-to-date review on the spectrum of new imaging applications in the practice of radiology. New imaging techniques have been developed with the objective of obtaining structural and functional analyses of different body systems. Recently, new imaging modalities have aroused the interest of many researchers who are studying the applicability of these modalities in the evaluation of different organs and diseases. In this review article, we present the efficiency and utilization of current imaging modalities in daily radiological practice.

  9. Stereotactic PET atlas of the human brain: Aid for visual interpretation of functional brain images

    SciTech Connect

    Minoshima, S.; Koeppe, R.A.; Frey, A.; Ishihara, M.; Kuhl, D.E.

    1994-06-01

    In the routine analysis of functional brain images obtained by PET, subjective visual interpretation is often used for anatomic localization. To enhance the accuracy and consistency of the anatomic interpretation, a PET stereotactic atlas and localization approach was designed for functional brain images. The PET atlas was constructed from a high-resolution [{sup 18}F]fluorodeoxyglucose (FDG) image set of a normal volunteer (a 41-yr-ld woman). The image set was reoriented stereotactically, according to the intercommissural (anterior and posterior commissures) line and transformed to the standard stereotactic atlas coordinates. Cerebral structures were annotated on the transaxial planes using a proportional grid system and surface-rendered images. The stereotactic localization technique was applied to image sets from patients with Alzheimer`s disease, and areas of functional alteration were localized visually by referring to the PET atlas. Major brain structures were identified on both transaxial planes and surface-rendered images. In the stereotactic system, anatomic correspondence between the PET atlas and stereotactically reoriented individual image sets of patients with Alzheimer`s disease facilitated both indirect and direct localization of the cerebral structures. Because rapid stereotactic alignment methods for PET images are now available for routine use, the PET atlas will serve as an aid for visual interpretation of functional brain images in the stereotactic system. Widespread application of stereotactic localization may be used in functional brain images, not only in the research setting, but also in routine clinical situations. 41 refs., 3 figs.

  10. EVolution: an edge-based variational method for non-rigid multi-modal image registration

    NASA Astrophysics Data System (ADS)

    de Senneville, B. Denis; Zachiu, C.; Ries, M.; Moonen, C.

    2016-10-01

    Image registration is part of a large variety of medical applications including diagnosis, monitoring disease progression and/or treatment effectiveness and, more recently, therapy guidance. Such applications usually involve several imaging modalities such as ultrasound, computed tomography, positron emission tomography, x-ray or magnetic resonance imaging, either separately or combined. In the current work, we propose a non-rigid multi-modal registration method (namely EVolution: an edge-based variational method for non-rigid multi-modal image registration) that aims at maximizing edge alignment between the images being registered. The proposed algorithm requires only contrasts between physiological tissues, preferably present in both image modalities, and assumes deformable/elastic tissues. Given both is shown to be well suitable for non-rigid co-registration across different image types/contrasts (T1/T2) as well as different modalities (CT/MRI). This is achieved using a variational scheme that provides a fast algorithm with a low number of control parameters. Results obtained on an annotated CT data set were comparable to the ones provided by state-of-the-art multi-modal image registration algorithms, for all tested experimental conditions (image pre-filtering, image intensity variation, noise perturbation). Moreover, we demonstrate that, compared to existing approaches, our method possesses increased robustness to transient structures (i.e. that are only present in some of the images).

  11. Neurosarcoidosis on FET and FDG PET/CT.

    PubMed

    Chan, Mico; Hsiao, Edward

    2017-03-01

    O-(2-fluoroethyl)-L-tyrosine (FET) PET/CT is a promising imaging modality for brain tumor imaging because of its reported high sensitivity for biologically active tumor tissue. We present a case of biopsy-proven neurosarcoidosis showing FET uptake. It is an important cause of false-positive uptake on FET PET/CT.

  12. Polyglucose nanoparticles with renal elimination and macrophage avidity facilitate PET imaging in ischaemic heart disease

    PubMed Central

    Keliher, Edmund J.; Ye, Yu-Xiang; Wojtkiewicz, Gregory R.; Aguirre, Aaron D.; Tricot, Benoit; Senders, Max L.; Groenen, Hannah; Fay, Francois; Perez-Medina, Carlos; Calcagno, Claudia; Carlucci, Giuseppe; Reiner, Thomas; Sun, Yuan; Courties, Gabriel; Iwamoto, Yoshiko; Kim, Hye-Yeong; Wang, Cuihua; Chen, John W.; Swirski, Filip K.; Wey, Hsiao-Ying; Hooker, Jacob; Fayad, Zahi A.; Mulder, Willem J. M.; Weissleder, Ralph; Nahrendorf, Matthias

    2017-01-01

    Tissue macrophage numbers vary during health versus disease. Abundant inflammatory macrophages destruct tissues, leading to atherosclerosis, myocardial infarction and heart failure. Emerging therapeutic options create interest in monitoring macrophages in patients. Here we describe positron emission tomography (PET) imaging with 18F-Macroflor, a modified polyglucose nanoparticle with high avidity for macrophages. Due to its small size, Macroflor is excreted renally, a prerequisite for imaging with the isotope flourine-18. The particle's short blood half-life, measured in three species, including a primate, enables macrophage imaging in inflamed cardiovascular tissues. Macroflor enriches in cardiac and plaque macrophages, thereby increasing PET signal in murine infarcts and both mouse and rabbit atherosclerotic plaques. In PET/magnetic resonance imaging (MRI) experiments, Macroflor PET imaging detects changes in macrophage population size while molecular MRI reports on increasing or resolving inflammation. These data suggest that Macroflor PET/MRI could be a clinical tool to non-invasively monitor macrophage biology. PMID:28091604

  13. single-channel stereoscopic video imaging modality based on a transparent rotating deflector

    NASA Astrophysics Data System (ADS)

    Radfar, Edalat; Park, Jihoon; Jun, Eunkwon; Ha, Myungjin; Lee, Sangyeob; Yu, SungKon; Jang, Seul G.; Jung, Byungjo

    2015-03-01

    This paper introduces a stereoscopic video imaging modality based on a transparent rotating deflector (TRD). Sequential two-dimensional (2D) left and right images were obtained by rotating the TRD on a stepping motor synchronized with a complementary metal-oxide semiconductor camera, and the components of the imaging modality were controlled through general purpose input/output ports using a microcontroller unit. In this research, live stereoscopic videos were visualized on a personal computer by both active shutter 3D and passive polarization 3D methods. The imaging modality was characterized by evaluating the stereoscopic video image generation, rotation characteristics of the TRD. The level of 3D conception was estimated in terms of simplified human stereovision. The results show that singlechannel stereoscopic video imaging modality has the potential to become an economical compact stereoscopic device as the system components are amenable to miniaturization; and could be applied in a wide variety of fields.

  14. Radiation dose reduction and new image modalities development for interventional C-arm imaging system

    NASA Astrophysics Data System (ADS)

    Niu, Kai

    Cardiovascular disease and stroke are the leading health problems and causes of death in the US. Due to the minimally invasive nature of the evolution of image guided techniques, interventional radiological procedures are becoming more common and are preferred in treating many cardiovascular diseases and strokes. In addition, with the recent advances in hardware and device technology, the speed and efficacy of interventional treatment has significantly improved. This implies that more image modalities can be developed based on the current C-arm system and patients treated in interventional suites can potentially experience better health outcomes. However, during the treatment patients are irradiated with substantial amounts of ionizing radiation with a high dose rate (digital subtraction angiography (DSA) with 3muGy/frame and 3D cone beam CT image with 0.36muGy/frame for a Siemens Artis Zee biplane system) and/or a long irradiation time (a roadmapping image sequence can be as long as one hour during aneurysm embolization). As a result, the patient entrance dose is extremely high. Despite the fact that the radiation dose is already substantial, image quality is not always satisfactory. By default a temporal average is used in roadmapping images to overcome poor image quality, but this technique can result in motion blurred images. Therefore, reducing radiation dose while maintaining or even improving the image quality is an important area for continued research. This thesis is focused on improving the clinical applications of C-arm cone beam CT systems in two ways: (1) Improve the performance of current image modalities on the C-arm system. (2) Develop new image modalities based on the current system. To be more specific, the objectives are to reduce radiation dose for current modalities (e.g., DSA, fluoroscopy, roadmapping, and cone beam CT) and enable cone beam CT perfusion and time resolved cone beam CT angiography that can be used to diagnose and triage acute

  15. Quantitative image reconstruction for total-body PET imaging using the 2-meter long EXPLORER scanner.

    PubMed

    Zhang, Xuezhu; Zhou, Jian; Cherry, Simon R; Badawi, Ramsey D; Qi, Jinyi

    2017-03-21

    The EXPLORER project aims to build a 2 meter long total-body PET scanner, which will provide extremely high sensitivity for imaging the entire human body. It will possess a range of capabilities currently unavailable to state-of-the-art clinical PET scanners with a limited axial field-of-view. The huge number of lines-of-response (LORs) of the EXPLORER poses a challenge to the data handling and image reconstruction. The objective of this study is to develop a quantitative image reconstruction method for the EXPLORER and compare its performance with current whole-body scanners. Fully 3D image reconstruction was performed using time-of-flight list-mode data with parallel computation. To recover the resolution loss caused by the parallax error between crystal pairs at a large axial ring difference or transaxial radial offset, we applied an image domain resolution model estimated from point source data. To evaluate the image quality, we conducted computer simulations using the SimSET Monte-Carlo toolkit and XCAT 2.0 anthropomorphic phantom to mimic a 20 min whole-body PET scan with an injection of 25 MBq (18)F-FDG. We compare the performance of the EXPLORER with a current clinical scanner that has an axial FOV of 22 cm. The comparison results demonstrated superior image quality from the EXPLORER with a 6.9-fold reduction in noise standard deviation comparing with multi-bed imaging using the clinical scanner.

  16. Quantitative image reconstruction for total-body PET imaging using the 2-meter long EXPLORER scanner

    NASA Astrophysics Data System (ADS)

    Zhang, Xuezhu; Zhou, Jian; Cherry, Simon R.; Badawi, Ramsey D.; Qi, Jinyi

    2017-03-01

    The EXPLORER project aims to build a 2 meter long total-body PET scanner, which will provide extremely high sensitivity for imaging the entire human body. It will possess a range of capabilities currently unavailable to state-of-the-art clinical PET scanners with a limited axial field-of-view. The huge number of lines-of-response (LORs) of the EXPLORER poses a challenge to the data handling and image reconstruction. The objective of this study is to develop a quantitative image reconstruction method for the EXPLORER and compare its performance with current whole-body scanners. Fully 3D image reconstruction was performed using time-of-flight list-mode data with parallel computation. To recover the resolution loss caused by the parallax error between crystal pairs at a large axial ring difference or transaxial radial offset, we applied an image domain resolution model estimated from point source data. To evaluate the image quality, we conducted computer simulations using the SimSET Monte–Carlo toolkit and XCAT 2.0 anthropomorphic phantom to mimic a 20 min whole-body PET scan with an injection of 25 MBq 18F-FDG. We compare the performance of the EXPLORER with a current clinical scanner that has an axial FOV of 22 cm. The comparison results demonstrated superior image quality from the EXPLORER with a 6.9-fold reduction in noise standard deviation comparing with multi-bed imaging using the clinical scanner.

  17. In Vivo Imaging of GLP-1R with a Targeted Bimodal PET/Fluorescence Imaging Agent

    PubMed Central

    2015-01-01

    Accurate visualization and quantification of β-cell mass is critical for the improved understanding, diagnosis, and treatment of both type 1 diabetes (T1D) and insulinoma. Here, we describe the synthesis of a bimodal imaging probe (PET/fluorescence) for imaging GLP-1R expression in the pancreas and in pancreatic islet cell tumors. The conjugation of a bimodal imaging tag containing a near-infrared fluorescent dye, and the copper chelator sarcophagine to the GLP-1R targeting peptide exendin-4 provided the basis for the bimodal imaging probe. Conjugation was performed via a novel sequential one-pot synthetic procedure including 64Cu radiolabeling and copper-catalyzed click-conjugation. The bimodal imaging agent 64Cu-E4-Fl was synthesized in good radiochemical yield and specific activity (RCY = 36%, specific activity: 141 μCi/μg, >98% radiochemical purity). The agent showed good performance in vivo and ex vivo, visualizing small xenografts (<2 mm) with PET and pancreatic β-cell mass by phosphor autoradiography. Using the fluorescent properties of the probe, we were able to detect individual pancreatic islets, confirming specific binding to GLP-1R and surpassing the sensitivity of the radioactive label. The use of bimodal PET/fluorescent imaging probes is promising for preoperative imaging and fluorescence-assisted analysis of patient tissues. We believe that our procedure could become relevant as a protocol for the development of bimodal imaging agents. PMID:24856928

  18. PSMA-Based [18F]DCFPyL PET/CT Is Superior to Conventional Imaging for Lesion Detection in Patients with Metastatic Prostate Cancer

    PubMed Central

    Rowe, Steven P.; Macura, Katarzyna J.; Mena, Esther; Blackford, Amanda L.; Nadal, Rosa; Antonarakis, Emmanuel S.; Eisenberger, Mario; Carducci, Michael; Fan, Hong; Dannals, Robert F.; Chen, Ying; Mease, Ronnie C.; Szabo, Zsolt; Pomper, Martin G.; Cho, Steve Y.

    2017-01-01

    Purpose Current standard of care conventional imaging modalities (CIM) such as X-ray computed tomography (CT) and bone scan can be limited for detection of metastatic prostate cancer and therefore improved imaging methods are an unmet clinical need. We evaluated the utility of a novel second-generation low molecular weight radiofluorinated prostate-specific membrane antigen (PSMA)-targeted positron emission tomography (PET) radiotracer, [18F]DCFPyL, in patients with metastatic prostate cancer. Procedures Nine patients with suspected prostate cancer recurrence, eight with CIM evidence of metastatic prostate cancer and one with biochemical recurrence, were imaged with [18F]DCFPyL PET/CT. Eight of the patients had contemporaneous CIM for comparison. A lesion-by-lesion comparison of the detection of suspected sites of metastatic prostate cancer was carried out between PET and CIM. Statistical analysis for estimated proportions of inter-modality agreement for detection of metastatic disease was calculated accounting for intra-patient correlation using general estimating equation (GEE) intercept-only regression models. Results One hundred thirty-nine sites of PET positive [18F]DCFPyL uptake (138 definite, 1 equivocal) for metastatic disease were detected in the eight patients with available comparison CIM. By contrast, only 45 lesions were identified on CIM (30 definite, 15 equivocal). When lesions were negative or equivocal on CIM, it was estimated that a large portion of these lesions or 0.72 (95 % confidence interval (CI) 0.55–0.84) would be positive on [18F]DCFPyL PET. Conversely, of those lesions negative or equivocal on [18F]DCFPyL PET, it was estimated that only a very small proportion or 0.03 (95 % CI 0.01–0.07) would be positive on CIM. Delayed 2-h-post-injection time point PET yielded higher tumor radiotracer uptake and higher tumor-to-background ratios than an earlier 1-h-post-injection time point. Conclusions A novel PSMA-targeted PET radiotracer, [18F

  19. Nonrigid Image Registration for Head and Neck Cancer Radiotherapy Treatment Planning With PET/CT

    SciTech Connect

    Ireland, Rob H. . E-mail: r.ireland@sheffield.ac.uk; Dyker, Karen E.; Barber, David C.; Wood, Steven M.; Hanney, Michael B.; Tindale, Wendy B.; Woodhouse, Neil; Hoggard, Nigel; Conway, John; Robinson, Martin H.

    2007-07-01

    Purpose: Head and neck radiotherapy planning with positron emission tomography/computed tomography (PET/CT) requires the images to be reliably registered with treatment planning CT. Acquiring PET/CT in treatment position is problematic, and in practice for some patients it may be beneficial to use diagnostic PET/CT for radiotherapy planning. Therefore, the aim of this study was first to quantify the image registration accuracy of PET/CT to radiotherapy CT and, second, to assess whether PET/CT acquired in diagnostic position can be registered to planning CT. Methods and Materials: Positron emission tomography/CT acquired in diagnostic and treatment position for five patients with head and neck cancer was registered to radiotherapy planning CT using both rigid and nonrigid image registration. The root mean squared error for each method was calculated from a set of anatomic landmarks marked by four independent observers. Results: Nonrigid and rigid registration errors for treatment position PET/CT to planning CT were 2.77 {+-} 0.80 mm and 4.96 {+-} 2.38 mm, respectively, p = 0.001. Applying the nonrigid registration to diagnostic position PET/CT produced a more accurate match to the planning CT than rigid registration of treatment position PET/CT (3.20 {+-} 1.22 mm and 4.96 {+-} 2.38 mm, respectively, p = 0.012). Conclusions: Nonrigid registration provides a more accurate registration of head and neck PET/CT to treatment planning CT than rigid registration. In addition, nonrigid registration of PET/CT acquired with patients in a standardized, diagnostic position can provide images registered to planning CT with greater accuracy than a rigid registration of PET/CT images acquired in treatment position. This may allow greater flexibility in the timing of PET/CT for head and neck cancer patients due to undergo radiotherapy.

  20. Radiolabeled Peptide Scaffolds for PET/SPECT - Optical in Vivo Imaging of Carbohydrate-Lectin Interactions

    SciTech Connect

    Deutscher, Susan

    2014-09-30

    The objective of this research is to develop phage display-selected peptides into radio- and fluoresecently- labeled scaffolds for the multimodal imaging of carbohydrate-lectin interactions. While numerous protein and receptor systems are being explored for the development of targeted imaging agents, the targeting and analysis of carbohydrate-lectin complexes in vivo remains relatively unexplored. Antibodies, nanoparticles, and peptides are being developed that target carbohydrate-lectin complexes in living systems. However, antibodies and nanoparticles often suffer from slow clearance and toxicity problems. Peptides are attractive alternative vehicles for the specific delivery of radionuclides or fluorophores to sites of interest in vivo, although, because of their size, uptake and retention may be less than antibodies. We have selected high affinity peptides that bind a specific carbohydrate-lectin complex involved in cell-cell adhesion and cross-linking using bacteriophage (phage) display technologies (1,2). These peptides have allowed us to probe the role of these antigens in cell adhesion. Fluorescent versions of the peptides have been developed for optical imaging and radiolabeled versions have been used in single photon emission computed tomography (SPECT) and positron emission tomography (PET) in vivo imaging (3-6). A benefit in employing the radiolabeled peptides in SPECT and PET is that these imaging modalities are widely used in living systems and offer deep tissue sensitivity. Radiolabeled peptides, however, often exhibit poor stability and high kidney uptake in vivo. Conversely, optical imaging is sensitive and offers good spatial resolution, but is not useful for deep tissue penetration and is semi-quantitative. Thus, multimodality imaging that relies on the strengths of both radio- and optical- imaging is a current focus for development of new in vivo imaging agents. We propose a novel means to improve the efficacy of radiolabeled and fluorescently

  1. Multiscale segmentation of the skull in MR images for MRI-based attenuation correction of combined MR/PET

    PubMed Central

    Yang, Xiaofeng; Fei, Baowei

    2013-01-01

    Background and objective Combined magnetic resonance/positron emission tomography (MR/PET) is a relatively new, hybrid imaging modality. MR-based attenuation correction often requires segmentation of the bone on MR images. In this study, we present an automatic segmentation method for the skull on MR images for attenuation correction in brain MR/PET applications. Materials and methods Our method transforms T1-weighted MR images to the Radon domain and then detects the features of the skull image. In the Radon domain we use a bilateral filter to construct a multiscale image series. For the repeated convolution we increase the spatial smoothing in each scale and make the width of the spatial and range Gaussian function doubled in each scale. Two filters with different kernels along the vertical direction are applied along the scales from the coarse to fine levels. The results from a coarse scale give a mask for the next fine scale and supervise the segmentation in the next fine scale. The use of the multiscale bilateral filtering scheme is to improve the robustness of the method for noise MR images. After combining the two filtered sinograms, the reciprocal binary sinogram of the skull is obtained for the reconstruction of the skull image. Results This method has been tested with brain phantom data, simulated brain data, and real MRI data. For real MRI data the Dice overlap ratios are 92.2%±1.9% between our segmentation and manual segmentation. Conclusions The multiscale segmentation method is robust and accurate and can be used for MRI-based attenuation correction in combined MR/PET. PMID:23761683

  2. Optimising rigid motion compensation for small animal brain PET imaging

    NASA Astrophysics Data System (ADS)

    Spangler-Bickell, Matthew G.; Zhou, Lin; Kyme, Andre Z.; De Laat, Bart; Fulton, Roger R.; Nuyts, Johan

    2016-10-01

    Motion compensation (MC) in PET brain imaging of awake small animals is attracting increased attention in preclinical studies since it avoids the confounding effects of anaesthesia and enables behavioural tests during the scan. A popular MC technique is to use multiple external cameras to track the motion of the animal’s head, which is assumed to be represented by the motion of a marker attached to its forehead. In this study we have explored several methods to improve the experimental setup and the reconstruction procedures of this method: optimising the camera-marker separation; improving the temporal synchronisation between the motion tracker measurements and the list-mode stream; post-acquisition smoothing and interpolation of the motion data; and list-mode reconstruction with appropriately selected subsets. These techniques have been tested and verified on measurements of a moving resolution phantom and brain scans of an awake rat. The proposed techniques improved the reconstructed spatial resolution of the phantom by 27% and of the rat brain by 14%. We suggest a set of optimal parameter values to use for awake animal PET studies and discuss the relative significance of each parameter choice.

  3. Brain tissue segmentation in PET-CT images using probabilistic atlas and variational Bayes inference.

    PubMed

    Xia, Yong; Wang, Jiabin; Eberl, Stefan; Fulham, Michael; Feng, David Dagan

    2011-01-01

    PET-CT provides aligned anatomical (CT) and functional (PET) images in a single scan, and has the potential to improve brain PET image segmentation, which can in turn improve quantitative clinical analyses. We propose a statistical segmentation algorithm that incorporates the prior anatomical knowledge represented by probabilistic brain atlas into the variational Bayes inference to delineate gray matter (GM), white matter (WM) and cerebrospinal fluid (CSF) in brain PET-CT images. Our approach adds an additional novel aspect by allowing voxels to have variable and adaptive prior probabilities of belonging to each class. We compared our algorithm to the segmentation approaches implemented in the expectation maximization segmentation (EMS) and statistical parametric mapping (SPM8) packages in 26 clinical cases. The results show that our algorithm improves the accuracy of brain PET-CT image segmentation.

  4. Effects of injected dose, BMI and scanner type on NECR and image noise in PET imaging.

    PubMed

    Chang, Tingting; Chang, Guoping; Kohlmyer, Steve; Clark, John W; Rohren, Eric; Mawlawi, Osama R

    2011-08-21

    Noise equivalent count rate (NECR) and image noise are two different but related metrics that have been used to predict and assess image quality, respectively. The aim of this study is to investigate, using patient studies, the relationships between injected dose (ID), body mass index (BMI) and scanner type on NECR and image noise measurements in PET imaging. Two groups of 90 patients each were imaged on a GE DSTE and a DRX PET/CT scanner, respectively. The patients in each group were divided into nine subgroups according to three BMI (20-24.9, 25-29.9, 30-45 kg m(-2)) and three ID (296-444, 444-555, 555-740 MBq) ranges, resulting in ten patients/subgroup. All PET data were acquired in 3D mode and reconstructed using the VuePoint HD® fully 3D OSEM algorithm (2 iterations, 21(DRX) or 20 (DSTE) subsets). NECR and image noise measurements for bed positions covering the liver were calculated for each patient. NECR was calculated from the trues, randoms and scatter events recorded in the DICOM header of each patient study, while image noise was determined as the standard deviation of 50 non-neighboring voxels in the liver of each patient. A t-test compared the NECR and image noise for different scanners but with the same BMI and ID. An ANOVA test on the other hand was used to compare the results of patients with different BMI but the same ID and scanner type as well as different ID but the same BMI and scanner type. As expected the t-test showed a significant difference in NECR between the two scanners for all BMI and ID subgroups. However, contrary to what is expected no such findings were observed for image noise measurement. The ANOVA results showed a statistically significant difference in both NECR and image noise among the different BMI for each ID and scanner subgroup. However, there was no statistically significant difference in NECR and image noise across different ID for each BMI and scanner subgroup. Although the GE DRX PET/CT scanner has better count rate

  5. Heterogeneity in stabilization phenomena in FLT PET images of canines

    PubMed Central

    Simoncic, Urban; Jeraj, Robert

    2014-01-01

    3′-(18F)fluoro-3′-deoxy-L-thymidine (FLT) is a PET marker of cellular proliferation. Its tissue uptake rate is often quantified with a Standardized Uptake Value (SUV), although kinetic analysis provides a more accurate quantification. The purpose of this study is to investigate the heterogeneity in FLT stabilization phenomena. The study was done on 15 canines with spontaneously occurring sinonasal tumours. They were imaged dynamically for 90 min with FLT PET/CT twice; before and during the radiotherapy. Images were analyzed for kinetics on a voxel basis through compartmental analysis. Stabilization curves were calculated as a time-dependant correlation between the time-dependant SUV and the kinetic parameters (voxel values within the tumour were correlated). Stabilization curves were analyzed for stabilization speed, maximal correlation and correlation decrease following the maximal correlation. These stabilization parameters were correlated with the region-averaged kinetic parameters. The FLT SUV was highly correlated with vasculature fraction immediately post-injection, followed by maximum in correlation with the perfusion/permeability. At later times post-injection the FLT SUV was highly correlated (Pearson correlation coefficient above 0.95) with the FLT influx parameter for cases with tumour-averaged SUV30–50min above 2, while others were indeterminate (correlation coefficients from 0.1 to 0.97). All cases with highly correlated SUV and FLT influx parameter had correlation coefficient within 0.5% of its maximum in the period of 30–50 min post-injection. Stabilization time was inversely proportional to the FLT influx rate. Correlation between the FLT SUV and FLT influx parameter dropped at later times post-injection with drop being proportional to the dephosphorylation rate. The FLT was found to be metabolically stable in canines. FLT PET imaging protocol should define minimal and maximal FLT uptake period, which would be 30–50 min for our patients

  6. ImmunoPET and Near-Infrared Fluorescence Imaging of Pancreatic Cancer with a Dual-Labeled Bispecific Antibody Fragment.

    PubMed

    Luo, Haiming; England, Christopher G; Goel, Shreya; Graves, Stephen A; Ai, Fanrong; Liu, Bai; Theuer, Charles P; Wong, Hing C; Nickles, Robert J; Cai, Weibo

    2017-03-24

    Dual-targeted imaging agents have shown improved targeting efficiencies in comparison to single-targeted entities. The purpose of this study was to quantitatively assess the tumor accumulation of a dual-labeled heterobifunctional imaging agent, targeting two overexpressed biomarkers in pancreatic cancer, using positron emission tomography (PET) and near-infrared fluorescence (NIRF) imaging modalities. A bispecific immunoconjugate (heterodimer) of CD105 and tissue factor (TF) Fab' antibody fragments was developed using click chemistry. The heterodimer was dual-labeled with a radionuclide ((64)Cu) and fluorescent dye. PET/NIRF imaging and biodistribution studies were performed in four-to-five week old nude athymic mice bearing BxPC-3 (CD105/TF(+/+)) or PANC-1 (CD105/TF(-/-)) tumor xenografts. A blocking study was conducted to investigate the specificity of the tracer. Ex vivo tissue staining was performed to compare TF/CD105 expression in tissues with PET tracer uptake to validate in vivo results. PET imaging of (64)Cu-NOTA-heterodimer-ZW800 in BxPC-3 tumor xenografts revealed enhanced tumor uptake (21.0 ± 3.4%ID/g; n = 4) compared to the homodimer of TRC-105 (9.6 ± 2.0%ID/g; n = 4; p < 0.01) and ALT-836 (7.6 ± 3.7%ID/g; n = 4; p < 0.01) at 24 h postinjection. Blocking studies revealed that tracer uptake in BxPC-3 tumors could be decreased by 4-fold with TF blocking and 2-fold with CD105 blocking. In the negative model (PANC-1), heterodimer uptake was significantly lower than that found in the BxPC-3 model (3.5 ± 1.1%ID/g; n = 4; p < 0.01). The specificity was confirmed by the successful blocking of CD105 or TF, which demonstrated that the dual targeting with (64)Cu-NOTA-heterodimer-ZW800 provided an improvement in overall tumor accumulation. Also, fluorescence imaging validated the PET imaging, allowing for clear delineation of the xenograft tumors. Dual-labeled heterodimeric imaging agents, like (64)Cu-NOTA-heterodimer-ZW800, may increase the overall tumor

  7. Towards integration of PET/MR hybrid imaging into radiation therapy treatment planning

    SciTech Connect

    Paulus, Daniel H.; Thorwath, Daniela; Schmidt, Holger; Quick, Harald H.

    2014-07-15

    Purpose: Multimodality imaging has become an important adjunct of state-of-the-art radiation therapy (RT) treatment planning. Recently, simultaneous PET/MR hybrid imaging has become clinically available and may also contribute to target volume delineation and biological individualization in RT planning. For integration of PET/MR hybrid imaging into RT treatment planning, compatible dedicated RT devices are required for accurate patient positioning. In this study, prototype RT positioning devices intended for PET/MR hybrid imaging are introduced and tested toward PET/MR compatibility and image quality. Methods: A prototype flat RT table overlay and two radiofrequency (RF) coil holders that each fix one flexible body matrix RF coil for RT head/neck imaging have been evaluated within this study. MR image quality with the RT head setup was compared to the actual PET/MR setup with a dedicated head RF coil. PET photon attenuation and CT-based attenuation correction (AC) of the hardware components has been quantitatively evaluated by phantom scans. Clinical application of the new RT setup in PET/MR imaging was evaluated in anin vivo study. Results: The RT table overlay and RF coil holders are fully PET/MR compatible. MR phantom and volunteer imaging with the RT head setup revealed high image quality, comparable to images acquired with the dedicated PET/MR head RF coil, albeit with 25% reduced SNR. Repositioning accuracy of the RF coil holders was below 1 mm. PET photon attenuation of the RT table overlay was calculated to be 3.8% and 13.8% for the RF coil holders. With CT-based AC of the devices, the underestimation error was reduced to 0.6% and 0.8%, respectively. Comparable results were found within the patient study. Conclusions: The newly designed RT devices for hybrid PET/MR imaging are PET and MR compatible. The mechanically rigid design and the reproducible positioning allow for straightforward CT-based AC. The systematic evaluation within this study provides the

  8. EXPLORER: Changing the molecular imaging paradigm with total-body PET/CT (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Cherry, Simon R.; Badawi, Ramsey D.; Jones, Terry

    2016-04-01

    Positron emission tomography (PET) is the highest sensitivity technique for human whole-body imaging studies. However, current clinical PET scanners do not make full use of the available signal, as they only permit imaging of a 15-25 cm segment of the body at one time. Given the limited sensitive region, whole-body imaging with clinical PET scanners requires relatively long scan times and subjects the patient to higher than necessary radiation doses. The EXPLORER initiative aims to build a 2-meter axial length PET scanner to allow imaging the entire subject at once, capturing nearly the entire available PET signal. EXPLORER will acquire data with ~40-fold greater sensitivity leading to a six-fold increase in reconstructed signal-to-noise ratio for imaging the total body. Alternatively, total-body images with the EXPLORER scanner will be able to be acquired in ~30 seconds or with ~0.15 mSv injected dose, while maintaining current PET image quality. The superior sensitivity will open many new avenues for biomedical research. Specifically for cancer applications, high sensitivity PET will enable detection of smaller lesions. Additionally, greater sensitivity will allow imaging out to 10 half-lives of positron emitting radiotracers. This will enable 1) metabolic ultra-staging with FDG by extending the uptake and clearance time to 3-5 hours to significantly improve contrast and 2) improved kinetic imaging with short-lived radioisotopes such as C-11, crucial for drug development studies. Frequent imaging studies of the same subject to study disease progression or to track response to therapy will be possible with the low dose capabilities of the EXPLORER scanner. The low dose capabilities will also open up new imaging possibilities in pediatrics and adolescents to better study developmental disorders. This talk will review the basis for developing total-body PET, potential applications, and review progress to date in developing EXPLORER, the first total-body PET scanner.

  9. Automatic co-segmentation of lung tumor based on random forest in PET-CT images

    NASA Astrophysics Data System (ADS)

    Jiang, Xueqing; Xiang, Dehui; Zhang, Bin; Zhu, Weifang; Shi, Fei; Chen, Xinjian

    2016-03-01

    In this paper, a fully automatic method is proposed to segment the lung tumor in clinical 3D PET-CT images. The proposed method effectively combines PET and CT information to make full use of the high contrast of PET images and superior spatial resolution of CT images. Our approach consists of three main parts: (1) initial segmentation, in which spines are removed in CT images and initial connected regions achieved by thresholding based segmentation in PET images; (2) coarse segmentation, in which monotonic downhill function is applied to rule out structures which have similar standardized uptake values (SUV) to the lung tumor but do not satisfy a monotonic property in PET images; (3) fine segmentation, random forests method is applied to accurately segment the lung tumor by extracting effective features from PET and CT images simultaneously. We validated our algorithm on a dataset which consists of 24 3D PET-CT images from different patients with non-small cell lung cancer (NSCLC). The average TPVF, FPVF and accuracy rate (ACC) were 83.65%, 0.05% and 99.93%, respectively. The correlation analysis shows our segmented lung tumor volumes has strong correlation ( average 0.985) with the ground truth 1 and ground truth 2 labeled by a clinical expert.

  10. Performance of three-photon PET imaging: Monte Carlo simulations.

    PubMed

    Kacperski, Krzysztof; Spyrou, Nicholas M

    2005-12-07

    We have recently introduced the idea of making use of three-photon positron annihilations in positron emission tomography. In this paper, the basic characteristics of the three-gamma imaging in PET are studied by means of Monte Carlo simulations and analytical computations. Two typical configurations of human and small animal scanners are considered. Three-photon imaging requires high-energy resolution detectors. Parameters currently attainable by CdZnTe semiconductor detectors, the technology of choice for the future development of radiation imaging, are assumed. Spatial resolution is calculated as a function of detector energy resolution and size, position in the field of view, scanner size and the energies of the three-gamma annihilation photons. Possible ways to improve the spatial resolution obtained for nominal parameters, 1.5 cm and 3.2 mm FWHM for human and small animal scanners, respectively, are indicated. Counting rates of true and random three-photon events for typical human and small animal scanning configurations are assessed. A simple formula for minimum size of lesions detectable in the three-gamma based images is derived. Depending on the contrast and total number of registered counts, lesions of a few mm size for human and sub mm for small animal scanners can be detected.

  11. Development of [F-18]-Labeled Amyloid Imaging Agents for PET

    SciTech Connect

    Mathis, CA

    2007-05-09

    The applicant proposes to design and synthesize a series of fluorine-18-labeled radiopharmaceuticals to be used as amyloid imaging agents for positron emission tomography (PET). The investigators will conduct comprehensive iterative in vitro and in vivo studies based upon well defined acceptance criteria in order to identify lead agents suitable for human studies. The long term goals are to apply the selected radiotracers as potential diagnostic agents of Alzheimer's disease (AD), as surrogate markers of amyloid in the brain to determine the efficacy of anti-amyloid therapeutic drugs, and as tools to help address basic scientific questions regarding the progression of the neuropathology of AD, such as testing the "amyloid cascade hypothesis" which holds that amyloid accumulation is the primary cause of AD.

  12. Clinical use of quantitative cardiac perfusion PET: rationale, modalities and possible indications. Position paper of the Cardiovascular Committee of the European Association of Nuclear Medicine (EANM).

    PubMed

    Sciagrà, Roberto; Passeri, Alessandro; Bucerius, Jan; Verberne, Hein J; Slart, Riemer H J A; Lindner, Oliver; Gimelli, Alessia; Hyafil, Fabien; Agostini, Denis; Übleis, Christopher; Hacker, Marcus

    2016-07-01

    Until recently, PET was regarded as a luxurious way of performing myocardial perfusion scintigraphy, with excellent image quality and diagnostic capabilities that hardly justified the additional cost and procedural effort. Quantitative perfusion PET was considered a major improvement over standard qualitative imaging, because it allows the measurement of parameters not otherwise available, but for many years its use was confined to academic and research settings. In recent years, however, several factors have contributed to the renewal of interest in quantitative perfusion PET, which has become a much more readily accessible technique due to progress in hardware and the availability of dedicated and user-friendly platforms and programs. In spite of this evolution and of the growing evidence that quantitative perfusion PET can play a role in the clinical setting, there are not yet clear indications for its clinical use. Therefore, the Cardiovascular Committee of the European Association of Nuclear Medicine, starting from the experience of its members, decided to examine the current literature on quantitative perfusion PET to (1) evaluate the rationale for its clinical use, (2) identify the main methodological requirements, (3) identify the remaining technical difficulties, (4) define the most reliable interpretation criteria, and finally (5) tentatively delineate currently acceptable and possibly appropriate clinical indications. The present position paper must be considered as a starting point aiming to promote a wider use of quantitative perfusion PET and to encourage the conception and execution of the studies needed to definitely establish its role in clinical practice.

  13. Comparison of bootstrap resampling methods for 3-D PET imaging.

    PubMed

    Lartizien, C; Aubin, J-B; Buvat, I

    2010-07-01

    Two groups of bootstrap methods have been proposed to estimate the statistical properties of positron emission tomography (PET) images by generating multiple statistically equivalent data sets from few data samples. The first group generates resampled data based on a parametric approach assuming that data from which resampling is performed follows a Poisson distribution while the second group consists of nonparametric approaches. These methods either require a unique original sample or a series of statistically equivalent data that can be list-mode files or sinograms. Previous reports regarding these bootstrap approaches suggest different results. This work compares the accuracy of three of these bootstrap methods for 3-D PET imaging based on simulated data. Two methods are based on a unique file, namely a list-mode based nonparametric (LMNP) method and a sinogram based parametric (SP) method. The third method is a sinogram-based nonparametric (SNP) method. Another original method (extended LMNP) was also investigated, which is an extension of the LMNP methods based on deriving a resampled list-mode file by drawings events from multiple original list-mode files. Our comparison is based on the analysis of the statistical moments estimated on the repeated and resampled data. This includes the probability density function and the moments of order 1 and 2. Results show that the two methods based on multiple original data (SNP and extended LMNP) are the only methods that correctly estimate the statistical parameters. Performances of the LMNP and SP methods are variable. Simulated data used in this study were characterized by a high noise level. Differences among the tested strategies might be reduced with clinical data sets with lower noise.

  14. Combined SPECT/CT and PET/CT for breast imaging

    NASA Astrophysics Data System (ADS)

    Russo, Paolo; Larobina, Michele; Di Lillo, Francesca; Del Vecchio, Silvana; Mettivier, Giovanni

    2016-02-01

    In the field of nuclear medicine imaging, breast imaging for cancer diagnosis is still mainly based on 2D imaging techniques. Three-dimensional tomographic imaging with whole-body PET or SPECT scanners, when used for imaging the breast, has performance limits in terms of spatial resolution and sensitivity, which can be overcome only with a dedicated instrumentation. However, only few hybrid imaging systems for PET/CT or SPECT/CT dedicated to the breast have been developed in the last decade, providing complementary functional and anatomical information on normal breast tissue and lesions. These systems are still under development and clinical trials on just few patients have been reported; no commercial dedicated breast PET/CT or SPECT/CT is available. This paper reviews combined dedicated breast PET/CT and SPECT/CT scanners described in the recent literature, with focus on their technological aspects.

  15. In Vivo ¹⁸F-FDG-PET Imaging in Mouse Atherosclerosis.

    PubMed

    Mateo, Jesús; Bilbao, Izaskun; Vaquero, Juan José; Ruiz-Cabello, Jesús; España, Samuel

    2015-01-01

    Positron emission tomography (PET) is an important technique in cardiovascular research. Vascular inflammation detected by fluorodeoxyglucose (FDG)-PET has been shown to predict cardiovascular (CV) events independent of traditional risk factors and is also highly associated with overall burden of atherosclerosis. The use of PET imaging in mouse models of atherosclerosis is challenged by the reduced size of the scanned organs. However, the last generation of dedicated PET scanners has an improved spatial resolution (<1 mm) and increased sensitivity allowing those studies to be performed. Here, we describe a procedure to perform FDG-PET experiments in atherosclerosis mouse models, the required equipment for animal handling and imaging, and the tools and procedures for image analysis and validation of the results.

  16. Antibody-based PET imaging of amyloid beta in mouse models of Alzheimer's disease

    PubMed Central

    Sehlin, Dag; Fang, Xiaotian T.; Cato, Linda; Antoni, Gunnar; Lannfelt, Lars; Syvänen, Stina

    2016-01-01

    Owing to their specificity and high-affinity binding, monoclonal antibodies have potential as positron emission tomography (PET) radioligands and are currently used to image various targets in peripheral organs. However, in the central nervous system, antibody uptake is limited by the blood–brain barrier (BBB). Here we present a PET ligand to be used for diagnosis and evaluation of treatment effects in Alzheimer's disease. The amyloid β (Aβ) antibody mAb158 is radiolabelled and conjugated to a transferrin receptor antibody to enable receptor-mediated transcytosis across the BBB. PET imaging of two different mouse models with Aβ pathology clearly visualize Aβ in the brain. The PET signal increases with age and correlates closely with brain Aβ levels. Thus, we demonstrate that antibody-based PET ligands can be successfully used for brain imaging. PMID:26892305

  17. MR/PET or PET/MRI: does it matter?

    PubMed

    Beyer, Thomas; Moser, Ewald

    2013-02-01

    After the very successful clinical introduction of combined PET/CT imaging a decade ago, a hardware combination of PET and MR is following suit. Today, three different approaches towards integrated PET/MR have been proposed: (1) a triple-modality system with a 3T MRI and a time-of-flight PET/CT installed in adjacent rooms, (2) a tandem system with a 3T MRI and a time-of-flight PET/CT in a co-planar installation with a joint patient handling system, and (3) a fully-integrated system with a whole-body PET system mounted inside a 3T MRI system. This special issue of MAGMA brings together contributions from key experts in the field of PET/MR, PET/CT and CT. The various papers share the author's perspectives on the state-of-the-art PET/MR imaging with any of the three approaches mentioned above. In addition to several reviews discussing advantages and challenges of combining PET and MRI for clinical diagnostics, first clinical data are also presented. We expect this special issue to nurture future improvements in hardware, clinical protocols, and efficient post-processing strategies to further assess the diagnostic value of combined PET/MR imaging. It remains to be seen whether a so-called "killer application" for PET/MRI will surface. In that case PET/MR is likely to excel in pre-clinical and selected research applications for now. This special issue helps the readers to stay on track of this exciting development.

  18. Gold nanoclusters as contrast agents for fluorescent and X-ray dual-modality imaging.

    PubMed

    Zhang, Aili; Tu, Yu; Qin, Songbing; Li, Yan; Zhou, Juying; Chen, Na; Lu, Qiang; Zhang, Bingbo

    2012-04-15

    Multimodal imaging technique is an alternative approach to improve sensitivity of early cancer diagnosis. In this study, highly fluorescent and strong X-ray absorption coefficient gold nanoclusters (Au NCs) are synthesized as dual-modality imaging contrast agents (CAs) for fluorescent and X-ray dual-modality imaging. The experimental results show that the as-prepared Au NCs are well constructed with ultrasmall sizes, reliable fluorescent emission, high computed tomography (CT) value and fine biocompatibility. In vivo imaging results indicate that the obtained Au NCs are capable of fluorescent and X-ray enhanced imaging.

  19. Hierarchical Multi-modal Image Registration by Learning Common Feature Representations

    PubMed Central

    Ge, Hongkun; Wu, Guorong; Wang, Li; Gao, Yaozong

    2016-01-01

    Mutual information (MI) has been widely used for registering images with different modalities. Since most inter-modality registration methods simply estimate deformations in a local scale, but optimizing MI from the entire image, the estimated deformations for certain structures could be dominated by the surrounding unrelated structures. Also, since there often exist multiple structures in each image, the intensity correlation between two images could be complex and highly nonlinear, which makes global MI unable to precisely guide local image deformation. To solve these issues, we propose a hierarchical inter-modality registration method by robust feature matching. Specifically, we first select a small set of key points at salient image locations to drive the entire image registration. Since the original image features computed from different modalities are often difficult for direct comparison, we propose to learn their common feature representations by projecting them from their native feature spaces to a common space, where the correlations between corresponding features are maximized. Due to the large heterogeneity between two high-dimension feature distributions, we employ Kernel CCA (Canonical Correlation Analysis) to reveal such non-linear feature mappings. Then, our registration method can take advantage of the learned common features to reliably establish correspondences for key points from different modality images by robust feature matching. As more and more key points take part in the registration, our hierarchical feature-based image registration method can efficiently estimate the deformation pathway between two inter-modality images in a global to local manner. We have applied our proposed registration method to prostate CT and MR images, as well as the infant MR brain images in the first year of life. Experimental results show that our method can achieve more accurate registration results, compared to other state-of-the-art image registration

  20. Multi-Modal Curriculum Learning for Semi-Supervised Image Classification.

    PubMed

    Gong, Chen; Tao, Dacheng; Maybank, Stephen J; Liu, Wei; Kang, Guoliang; Yang, Jie

    2016-07-01

    Semi-supervised image classification aims to classify a large quantity of unlabeled images by typically harnessing scarce labeled images. Existing semi-supervised methods often suffer from inadequate classification accuracy when encountering difficult yet critical images, such as outliers, because they treat all unlabeled images equally and conduct classifications in an imperfectly ordered sequence. In this paper, we employ the curriculum learning methodology by investigating the difficulty of classifying every unlabeled image. The reliability and the discriminability of these unlabeled images are particularly investigated for evaluating their difficulty. As a result, an optimized image sequence is generated during the iterative propagations, and the unlabeled images are logically classified from simple to difficult. Furthermore, since images are usually characterized by multiple visual feature descriptors, we associate each kind of features with a teacher, and design a multi-modal curriculum learning (MMCL) strategy to integrate the information from different feature modalities. In each propagation, each teacher analyzes the difficulties of the currently unlabeled images from its own modality viewpoint. A consensus is subsequently reached among all the teachers, determining the currently simplest images (i.e., a curriculum), which are to be reliably classified by the multi-modal learner. This well-organized propagation process leveraging multiple teachers and one learner enables our MMCL to outperform five state-of-the-art methods on eight popular image data sets.

  1. Molecular Imaging and Precision Medicine: PET/Computed Tomography and Therapy Response Assessment in Oncology.

    PubMed

    Sheikhbahaei, Sara; Mena, Esther; Pattanayak, Puskar; Taghipour, Mehdi; Solnes, Lilja B; Subramaniam, Rathan M

    2017-01-01

    A variety of methods have been developed to assess tumor response to therapy. Standardized qualitative criteria based on 18F-fluoro-deoxyglucose PET/computed tomography have been proposed to evaluate the treatment effectiveness in specific cancers and these allow more accurate therapy response assessment and survival prognostication. Multiple studies have addressed the utility of the volumetric PET biomarkers as prognostic indicators but there is no consensus about the preferred segmentation methodology for these metrics. Heterogeneous intratumoral uptake was proposed as a novel PET metric for therapy response assessment. PET imaging techniques will be used to study the biological behavior of cancers during therapy.

  2. 123I-Mibg scintigraphy and 18F-Fdg-Pet imaging for diagnosing neuroblastoma

    PubMed Central

    Bleeker, Gitta; Tytgat, Godelieve Am; Adam, Judit A; Caron, Huib N; Kremer, Leontien Cm; Hooft, Lotty; van Dalen, Elvira C

    2015-01-01

    eligible patients included in the 11 studies, varied from 67% to 100%. One study, that reported on a lesion level, provided data to calculate the specificity: 68% in 115 lesions in 22 patients. The sensitivity of 123I-MIBG scintigraphy for detecting metastases separately from the primary tumour in patients with all neuroblastoma stages ranged from 79% to 100% in three studies and the specificity ranged from 33% to 89% for two of these studies. One study reported on the diagnostic accuracy of 18F-FDG-PET(-CT) imaging (add-on test) in patients with negative 123I-MIBG scintigraphy (objective 1.2). Two of the 24 eligible patients with proven neuroblastoma had a negative 123I-MIBG scan and a positive 18F-FDG-PET(-CT) scan. The sensitivity of 18F-FDG-PET(-CT) imaging as a single diagnostic test (objective 2.1) and compared to 123I-MIBG (SPECT-CT) (objective 2.2) was only reported in one study. The sensitivity of 18F-FDG-PET(-CT) imaging was 100% versus 92% of 123I-MIBG (SPECT-CT) scintigraphy. We could not calculate the specificity for both modalities. Authors' conclusions The reported sensitivities of 123-I MIBG scintigraphy for the detection of neuroblastoma and its metastases ranged from 67 to 100% in patients with histologically proven neuroblastoma. Only one study in this review reported on false positive findings. It is important to keep in mind that false positive findings can occur. For example, physiological uptake should be ruled out, by using SPECT-CT scans, although more research is needed before definitive conclusions can be made. As described both in the literature and in this review, in about 10% of the patients with histologically proven neuroblastoma the tumour does not accumulate 123I-MIBG (false negative results). For these patients, it is advisable to perform an additional test for staging and assess response to therapy. Additional tests might for example be 18F-FDG-PET(-CT), but to be certain of its clinical value, more evidence is needed. The diagnostic

  3. [68Ga]Pentixafor-PET/CT for imaging of chemokine receptor CXCR4 expression in multiple myeloma - Comparison to [18F]FDG and laboratory values

    PubMed Central

    Lapa, Constantin; Schreder, Martin; Schirbel, Andreas; Samnick, Samuel; Kortüm, Klaus Martin; Herrmann, Ken; Kropf, Saskia; Einsele, Herrmann; Buck, Andreas K.; Wester, Hans-Jürgen; Knop, Stefan; Lückerath, Katharina

    2017-01-01

    Chemokine (C-X-C motif) receptor 4 (CXCR4) is a key factor for tumor growth and metastasis in several types of human cancer including multiple myeloma (MM). Proof-of-concept of CXCR4-directed radionuclide therapy in MM has recently been reported. This study assessed the diagnostic performance of the CXCR4-directed radiotracer [68Ga]Pentixafor in MM and a potential role for stratifying patients to CXCR4-directed therapies. Thirty-five patients with MM underwent [68Ga]Pentixafor-PET/CT for evaluation of eligibility for endoradiotherapy. In 19/35 cases, [18F]FDG-PET/CT for correlation was available. Scans were compared on a patient and on a lesion basis. Tracer uptake was correlated with standard clinical parameters of disease activity. [68Ga]Pentixafor-PET detected CXCR4-positive disease in 23/35 subjects (66%). CXCR4-positivity at PET was independent from myeloma subtypes, cytogenetics or any serological parameters and turned out as a negative prognostic factor. In the 19 patients in whom a comparison to [18F]FDG was available, [68Ga]Pentixafor-PET detected more lesions in 4/19 (21%) subjects, [18F]FDG proved superior in 7/19 (37%). In the remaining 8/19 (42%) patients, both tracers detected an equal number of lesions. [18F]FDG-PET positivity correlated with [68Ga]Pentixafor-PET positivity (p=0.018). [68Ga]Pentixafor-PET provides further evidence that CXCR4 expression frequently occurs in advanced multiple myeloma, representing a negative prognostic factor and a potential target for myeloma specific treatment. However, selecting patients for CXCR4 directed therapies and prognostic stratification seem to be more relevant clinical applications for this novel imaging modality, rather than diagnostic imaging of myeloma. PMID:28042328

  4. Impact of metal artefacts due to EEG electrodes in brain PET/CT imaging

    NASA Astrophysics Data System (ADS)

    Lemmens, Catherine; Montandon, Marie-Louise; Nuyts, Johan; Ratib, Osman; Dupont, Patrick; Zaidi, Habib

    2008-08-01

    The goal of this study is to investigate the impact of electroencephalogram (EEG) electrodes on the visual quality and quantification of 18F-FDG PET images in neurological PET/CT examinations. For this purpose, the scans of 20 epilepsy patients with EEG monitoring were used. The CT data were reconstructed with filtered backprojection (FBP) and with a metal artefact reduction (MAR) algorithm. Both data sets were used for CT-based attenuation correction (AC) of the PET data. Also, a calculated AC (CALC) technique was considered. A volume of interest (VOI)-based analysis and a voxel-based quantitative analysis were performed to compare the different AC methods. Images were also evaluated visually by two observers. It was shown with simulations and phantom measurements that from the considered AC methods, the MAR-AC can be used as the reference in this setting. The visual assessment of PET images showed local hot spots outside the brain corresponding to the locations of the electrodes when using FBP-AC. In the brain, no abnormalities were observed. The quantitative analysis showed a very good correlation between PET-FBP-AC and PET-MAR-AC, with a statistically significant positive bias in the PET-FBP-AC images of about 5-7% in most brain voxels. There was also good correlation between PET-CALC-AC and PET-MAR-AC, but in the PET-CALC-AC images, regions with both a significant positive and negative bias were observed. EEG electrodes give rise to local hot spots outside the brain and a positive quantification bias in the brain. However, when diagnosis is made by mere visual assessment, the presence of EEG electrodes does not seem to alter the diagnosis. When quantification is performed, the bias becomes an issue especially when comparing brain images with and without EEG monitoring.

  5. New targets for the development of PET tracers for imaging neurodegeneration in Alzheimer disease.

    PubMed

    Mach, Robert H

    2014-08-01

    The field of molecular imaging has experienced significant advances in the area of Alzheimer disease (AD), the most significant being the development of PET radiotracers for imaging β-amyloid burden in the brain of individuals at risk for or in the early stages of AD. More recent advances include the development of PET radiotracers for imaging aggregates of hyperphosphorylated tau protein in neurofibrillary tangles, a process that occurs late in the disease process. This article highlights advances in the neurobiology of AD and describes how PET can be used to study the mechanisms of neurodegeneration in AD.

  6. Transmission imaging for integrated PET-MR systems

    NASA Astrophysics Data System (ADS)

    Bowen, Spencer L.; Fuin, Niccolò; Levine, Michael A.; Catana, Ciprian

    2016-08-01

    Attenuation correction for PET-MR systems continues to be a challenging problem, particularly for body regions outside the head. The simultaneous acquisition of transmission scan based μ-maps and MR images on integrated PET-MR systems may significantly increase the performance of and offer validation for new MR-based μ-map algorithms. For the Biograph mMR (Siemens Healthcare), however, use of conventional transmission schemes is not practical as the patient table and relatively small diameter scanner bore significantly restrict radioactive source motion and limit source placement. We propose a method for emission-free coincidence transmission imaging on the Biograph mMR. The intended application is not for routine subject imaging, but rather to improve and validate MR-based μ-map algorithms; particularly for patient implant and scanner hardware attenuation correction. In this study we optimized source geometry and assessed the method’s performance with Monte Carlo simulations and phantom scans. We utilized a Bayesian reconstruction algorithm, which directly generates μ-map estimates from multiple bed positions, combined with a robust scatter correction method. For simulations with a pelvis phantom a single torus produced peak noise equivalent count rates (34.8 kcps) dramatically larger than a full axial length ring (11.32 kcps) and conventional rotating source configurations. Bias in reconstructed μ-maps for head and pelvis simulations was  ⩽4% for soft tissue and  ⩽11% for bone ROIs. An implementation of the single torus source was filled with 18F-fluorodeoxyglucose and the proposed method quantified for several test cases alone or in comparison with CT-derived μ-maps. A volume average of 0.095 cm-1 was recorded for an experimental uniform cylinder phantom scan, while a bias of  <2% was measured for the cortical bone equivalent insert of the multi-compartment phantom. Single torus μ-maps of a hip implant phantom showed significantly less

  7. Transmission imaging for integrated PET-MR systems.

    PubMed

    Bowen, Spencer L; Fuin, Niccolò; Levine, Michael A; Catana, Ciprian

    2016-08-07

    Attenuation correction for PET-MR systems continues to be a challenging problem, particularly for body regions outside the head. The simultaneous acquisition of transmission scan based μ-maps and MR images on integrated PET-MR systems may significantly increase the performance of and offer validation for new MR-based μ-map algorithms. For the Biograph mMR (Siemens Healthcare), however, use of conventional transmission schemes is not practical as the patient table and relatively small diameter scanner bore significantly restrict radioactive source motion and limit source placement. We propose a method for emission-free coincidence transmission imaging on the Biograph mMR. The intended application is not for routine subject imaging, but rather to improve and validate MR-based μ-map algorithms; particularly for patient implant and scanner hardware attenuation correction. In this study we optimized source geometry and assessed the method's performance with Monte Carlo simulations and phantom scans. We utilized a Bayesian reconstruction algorithm, which directly generates μ-map estimates from multiple bed positions, combined with a robust scatter correction method. For simulations with a pelvis phantom a single torus produced peak noise equivalent count rates (34.8 kcps) dramatically larger than a full axial length ring (11.32 kcps) and conventional rotating source configurations. Bias in reconstructed μ-maps for head and pelvis simulations was  ⩽4% for soft tissue and  ⩽11% for bone ROIs. An implementation of the single torus source was filled with (18)F-fluorodeoxyglucose and the proposed method quantified for several test cases alone or in comparison with CT-derived μ-maps. A volume average of 0.095 cm(-1) was recorded for an experimental uniform cylinder phantom scan, while a bias of  <2% was measured for the cortical bone equivalent insert of the multi-compartment phantom. Single torus μ-maps of a hip implant phantom showed significantly

  8. What Does PET Imaging Add to Conventional Staging of Head and Neck Cancer Patients?

    SciTech Connect

    Pohar, Surjeet . E-mail: poharss@evms.edu; Brown, Robert B.S.; Newman, Nancy; Koniarczyk, Michael; Hsu, Jack; Feiglin, David

    2007-06-01

    Purpose: To determine the value of PET scans in the staging of patients with head and neck carcinoma. Methods and Materials: The charts of 25 patients who underwent neck dissection, computed tomography (CT) scan, and F-18-fluorodeoxyglucose positron emission tomography (FDG-PET) imaging as part of their initial work-up for a head and neck squamous cell cancer between 2000-2003 were reviewed. All patients underwent clinical examination, triple endoscopy, and chest radiograph as part of their clinical staging, adhering to American Joint Commission for Cancer criteria. In addition to the clinical nodal (N) stage, PET findings were incorporated to determine a second type of N staging: clinical N + PET stage. The number of neck sides and nodal levels involved on CT or PET and on pathologic examination were recorded. Results: The sensitivity and specificity for detection of nodal disease were similar for CT and FDG-PET. Positive and negative likelihood ratios were similar for both diagnostic tests. None of our 25 patients had unsuspected distant disease detected by PET. Conclusion: The addition of PET imaging did not improve diagnostic accuracy in our patients compared with CT. PET scanning did not alter clinical management in any of the patients.

  9. 11C-Acetate PET/CT Imaging in Localized Prostate Cancer: A study with MRI and Histopathologic Correlation

    PubMed Central

    Mena, Esther; Turkbey, Baris; Mani, Haresh; Adler, Stephen; Valera, Vladimir A.; Bernardo, Marcelino; Shah, Vijay; Pohida, Thomas; McKinney, Yolanda; Kwarteng, Gideon; Daar, Dagane; Lindenberg, Maria L.; Eclarinal, Philip; Wade, Revia; Linehan, W. Marston; Merino, Maria J.; Pinto, Peter A.; Choyke, Peter L.; Kurdziel, Karen A.

    2012-01-01

    This work characterizes the uptake of 11C-Acetate in prostate cancer (PCa), benign prostate hyperplasia (BPH) and normal prostate tissue in comparison with multi-parametric MRI, whole mount histopathology and clinical markers, to evaluate its potential utility for delineating intra-prostatic tumors in a population of patients with localized PCa. METHODS 39 men with presumed localized PCa underwent dynamic/static abdomen-pelvic 11C-Acetate PET/CT for 30-minutes and 3T multi-parametric (MP) MRI prior to prostatectomy. PET/CT images were registered to MRI using pelvic bones for initial rotation-translation, followed by manual adjustments to account for prostate motion and deformation from the MRI endorectal coil. Whole-mount pathology specimens were sectioned using an MRI-based patient specific mold resulting in improved registration between the MRI, PET and pathology. 11C-Acetate PET standardized uptake values were compared with MP-MRI and pathology. RESULTS 11C-Acetate uptake was rapid but reversible, peaking at 3–5 minutes post-injection and reaching a relative plateau at ~10 minutes. The average SUVmax(10–12min) of tumors was significantly higher than that of normal prostate tissue (4.4±2.05, range 1.8–9.2 vs. 2.1±0.94, range 0.7–3.4; p<0.001); however it was not significantly different from benign prostatic hyperplasia (4.8±2.01; range 1.8–8.8). A sector-based comparison with histopathology, including all tumors > 0.5 cm, revealed a sensitivity and specificity of 61.6 % and 80.0 % for 11C-Acetate PET/CT, and 82.3% and 95.1% for MRI, respectively. Considering only tumors >0.9 cm the 11C-Acetate accuracy was comparable to that of MRI. In a small cohort (n=9), 11C-Acetate uptake was independent of fatty acid synthase expression based on immunohistochemistry. CONCLUSION 11C-Acetate PET/CT demonstrates higher uptake in tumor foci than normal prostate tissue; however 11C-Acetate uptake in tumors is similar to BPH nodules. While 11C-Acetate PET/CT is not

  10. Multimodal imaging: Simultaneous EEG in a 3T Hybrid MR-PET system

    NASA Astrophysics Data System (ADS)

    Neuner, I.; Warbrick, T.; Tellmann, L.; Rota Kops, E.; Arrubla, J.; Boers, F.; Herzog, H.; Shah, N. J.

    2013-02-01

    The new generation of integrated MR-PET systems allows the simultaneous acquisition of MR and PET data. While MR delivers structural data with an excellent spatial resolution, the advantage of PET is its information on a molecular level. However, both modalities have a low temporal resolution. Thus, for pharmacological studies or patients who suffer from treatment resistant epilepsy the combination of yet another modality such as EEG could be desirable. We tested the feasibility of evoked visual potentials in a 3T Hybrid MR-PET system (Siemens Germany) in comparison to a standalone 3T Trio System (Siemens Germany). A T2*-weighted EPI sequence was used: TR: 2.2 s, TE: 30 ms, FOV: 200 mm, slice thickness 3, 36 slices in a healthy volunteer (male, 27 years old) using an MR-compatible 32-channel EEG system (Brainproducts, Munich, Germany). We applied 200 trials of visual stimulation from a white and black checkerboard. Visual evoked potentials were analyzed using Brain Vision Analyzer (Brainproducts, Munich, Germany). Gradient correction and cardioballistic artefact correction were performed as implemented in Vision Analyzer. Visual event related potentials were successfully recorded at the 3T Hybrid MR-PET system. Both curves differ slightly in shape and latency due to the following factors: the distance from the screen varies slightly and the size of the field of view of the subjects is smaller in the 3T MR-PET system in comparison to the 3T stand alone system. Extending the 3T MR-PET Hybrid system to 3T Hybrid MR-PET-EEG is feasible and adds another tool to clinical neuroimaging and research.

  11. Positron Emission Tomography (PET)

    DOE R&D Accomplishments Database

    Welch, M. J.

    1990-01-01

    Positron emission tomography (PET) assesses biochemical processes in the living subject, producing images of function rather than form. Using PET, physicians are able to obtain not the anatomical information provided by other medical imaging techniques, but pictures of physiological activity. In metaphoric terms, traditional imaging methods supply a map of the body's roadways, its, anatomy; PET shows the traffic along those paths, its biochemistry. This document discusses the principles of PET, the radiopharmaceuticals in PET, PET research, clinical applications of PET, the cost of PET, training of individuals for PET, the role of the United States Department of Energy in PET, and the futures of PET.

  12. Positron Emission Tomography (PET)

    SciTech Connect

    Welch, M.J.

    1990-01-01

    Positron emission tomography (PET) assesses biochemical processes in the living subject, producing images of function rather than form. Using PET, physicians are able to obtain not the anatomical information provided by other medical imaging techniques, but pictures of physiological activity. In metaphoric terms, traditional imaging methods supply a map of the body's roadways, its, anatomy; PET shows the traffic along those paths, its biochemistry. This document discusses the principles of PET, the radiopharmaceuticals in PET, PET research, clinical applications of PET, the cost of PET, training of individuals for PET, the role of the United States Department of Energy in PET, and the futures of PET. 22 figs.

  13. MR-PET image coregistration for quantitation of striatal dopamine D{sub 2} receptors

    SciTech Connect

    Wang, G.J.; Volkow, N.D.; Levy, A.V.

    1996-05-01

    Our goal was to assess the utility of MR-PET image coregistration to quantify dopamine D{sub 2} receptors in striatum. Twenty-nine normal subjects were investigated with PET and [{sup 11}C]raclopride and with MRI. D{sub 2} receptors were quantified using the ratio of the distribution volume in striatum to that in cerebellum. Measures obtained using regions selected directly from the PET images were compared with those obtained from MR images and then projected to coregistered PET images. There were no differences between measures selected from the PET images (3.9 {+-} 0.5) and those from the MR images (3.9 {+-} 0.65). The values for these two measures were significantly correlated and corresponded to r = 0.9, P < 0.0001. Regions of interest selected directly from PET images, where there is a large contrast between the region of interest and background, as for the case of dopamine D{sub 2} ligands, are almost identical to those obtained from coregistered MR images. 24 refs., 4 figs., 1 tab.

  14. Respiratory motion correction in 4D-PET by simultaneous motion estimation and image reconstruction (SMEIR)

    NASA Astrophysics Data System (ADS)

    Kalantari, Faraz; Li, Tianfang; Jin, Mingwu; Wang, Jing

    2016-08-01

    In conventional 4D positron emission tomography (4D-PET), images from different frames are reconstructed individually and aligned by registration methods. Two issues that arise with this approach are as follows: (1) the reconstruction algorithms do not make full use of projection statistics; and (2) the registration between noisy images can result in poor alignment. In this study, we investigated the use of simultaneous motion estimation and image reconstruction (SMEIR) methods for motion estimation/correction in 4D-PET. A modified ordered-subset expectation maximization algorithm coupled with total variation minimization (OSEM-TV) was used to obtain a primary motion-compensated PET (pmc-PET) from all projection data, using Demons derived deformation vector fields (DVFs) as initial motion vectors. A motion model update was performed to obtain an optimal set of DVFs in the pmc-PET and other phases, by matching the forward projection of the deformed pmc-PET with measured projections from other phases. The OSEM-TV image reconstruction was repeated using updated DVFs, and new DVFs were estimated based on updated images. A 4D-XCAT phantom with typical FDG biodistribution was generated to evaluate the performance of the SMEIR algorithm in lung and liver tumors with different contrasts and different diameters (10-40 mm). The image quality of the 4D-PET was greatly improved by the SMEIR algorithm. When all projections were used to reconstruct 3D-PET without motion compensation, motion blurring artifacts were present, leading up to 150% tumor size overestimation and significant quantitative errors, including 50% underestimation of tumor contrast and 59% underestimation of tumor uptake. Errors were reduced to less than 10% in most images by using the SMEIR algorithm, showing its potential in motion estimation/correction in 4D-PET.

  15. TH-E-202-01: Pitfalls and Remedies in PET/CT Imaging for RT Planning.

    PubMed

    Pan, T

    2016-06-01

    PET/CT is a very important imaging tool in the management of oncology patients. PET/CT has been applied for treatment planning and response evaluation in radiation therapy. This educational session will discuss: 1. Pitfalls and remedies in PET/CT imaging for RT planning 2. The use of hypoxia PET imaging for radiotherapy 3. PET for tumor response evaluation The first presentation will address the issue of mis-registration between the CT and PET images in the thorax and the abdomen. We will discuss the challenges of respiratory gating and introduce an average CT technique to improve the registration for dose calculation and image-guidance in radiation therapy. The second presentation will discuss the use of hypoxia PET Imaging for radiation therapy. We will discuss various hypoxia radiotracers, the choice of clinical acquisition protocol (in particular a single late static acquisition versus a dynamic acquisition), and the compartmental modeling with different transfer rate constants explained. We will demonstrate applications of hypoxia imaging for dose escalation/de-escalation in clinical trials. The last presentation will discuss the use of PET/CT for tumor response evaluation. We will discuss anatomic response assessment vs. metabolic response assessment, visual evaluation and semi-quantitative evaluation, and limitations of current PET/CT assessment. We will summarize clinical trials using PET response in guiding adaptive radiotherapy. Finally, we will summarize recent advancements in PET/CT radiomics and non-FDG PET tracers for response assessment.

  16. A Survey of FDG- and Amyloid-PET Imaging in Dementia and GRADE Analysis

    PubMed Central

    Daniela, Perani; Orazio, Schillaci; Alessandro, Padovani; Mariano, Nobili Flavio; Leonardo, Iaccarino; Pasquale Anthony, Della Rosa; Giovanni, Frisoni; Carlo, Caltagirone

    2014-01-01

    PET based tools can improve the early diagnosis of Alzheimer's disease (AD) and differential diagnosis of dementia. The importance of identifying individuals at risk of developing dementia among people with subjective cognitive complaints or mild cognitive impairment has clinical, social, and therapeutic implications. Within the two major classes of AD biomarkers currently identified, that is, markers of pathology and neurodegeneration, amyloid- and FDG-PET imaging represent decisive tools for their measurement. As a consequence, the PET tools have been recognized to be of crucial value in the recent guidelines for the early diagnosis of AD and other dementia conditions. The references based recommendations, however, include large PET imaging literature based on visual methods that greatly reduces sensitivity and specificity and lacks a clear cut-off between normal and pathological findings. PET imaging can be assessed using parametric or voxel-wise analyses by comparing the subject's scan with a normative data set, significantly increasing the diagnostic accuracy. This paper is a survey of the relevant literature on FDG and amyloid-PET imaging aimed at providing the value of quantification for the early and differential diagnosis of AD. This allowed a meta-analysis and GRADE analysis revealing high values for PET imaging that might be useful in considering recommendations. PMID:24772437

  17. A survey of FDG- and amyloid-PET imaging in dementia and GRADE analysis.

    PubMed

    Perani, Daniela; Daniela, Perani; Schillaci, Orazio; Orazio, Schillaci; Padovani, Alessandro; Alessandro, Padovani; Nobili, Flavio Mariano; Mariano, Nobili Flavio; Iaccarino, Leonardo; Leonardo, Iaccarino; Della Rosa, Pasquale Anthony; Pasquale Anthony, Della Rosa; Frisoni, Giovanni; Giovanni, Frisoni; Caltagirone, Carlo; Carlo, Caltagirone

    2014-01-01

    PET based tools can improve the early diagnosis of Alzheimer's disease (AD) and differential diagnosis of dementia. The importance of identifying individuals at risk of developing dementia among people with subjective cognitive complaints or mild cognitive impairment has clinical, social, and therapeutic implications. Within the two major classes of AD biomarkers currently identified, that is, markers of pathology and neurodegeneration, amyloid- and FDG-PET imaging represent decisive tools for their measurement. As a consequence, the PET tools have been recognized to be of crucial value in the recent guidelines for the early diagnosis of AD and other dementia conditions. The references based recommendations, however, include large PET imaging literature based on visual methods that greatly reduces sensitivity and specificity and lacks a clear cut-off between normal and pathological findings. PET imaging can be assessed using parametric or voxel-wise analyses by comparing the subject's scan with a normative data set, significantly increasing the diagnostic accuracy. This paper is a survey of the relevant literature on FDG and amyloid-PET imaging aimed at providing the value of quantification for the early and differential diagnosis of AD. This allowed a meta-analysis and GRADE analysis revealing high values for PET imaging that might be useful in considering recommendations.

  18. (68)Ga-PSMA PET/MR with multimodality image analysis for primary prostate cancer.

    PubMed

    Eiber, Matthias; Nekolla, Stephan G; Maurer, Tobias; Weirich, Gregor; Wester, Hans-Jürgen; Schwaiger, Markus

    2015-08-01

    Current imaging procedures for prostate cancer including positron emission tomography (PET) exhibit considerable limitations and are not always able to meet the diagnostic needs. Recently, a (68)Gallium-labeled ligand of the prostate-specific membrane antigen ((68)Ga-PSMA) has been introduced in PET-imaging of prostate cancer with first promising results. Due to relatively exclusive expression of PSMA in prostatic tissue as well as increased expression in prostate cancer, 68 Ga-PSMA was reported to exhibit a favorable lesion to background ratio. Together with the novel development of combined PET/MRI, the combination of excellent morphological detail, multiparametric functional information, and molecular PET data might lead to a significant improvement in detection of prostate cancer. We present an exemplarily case of primary staging using multiparametric (68)Ga-PSMA PET/MR by combining molecular and structural information.

  19. The use of PET imaging in studying cognition, genetics and pharmacotherapeutic interventions in schizophrenia.

    PubMed

    Vyas, Nora S; Patel, Neva H; Nijran, Kuldip S; Al-Nahhas, Adil; Puri, Basant K

    2011-01-01

    Positron emission tomography (PET) offers a strategic imaging platform to provide a map of functional neural correlates associated with the underlying cognitive deficits in schizophrenia. It enables regional cerebral glucose metabolism and dopaminergic and serotonergic receptor function to be studied. PET neuroimaging can therefore be used in drug development and to study putative treatments. Recent PET studies of the first-generation antipsychotics flupentixol and haloperidol, and of the second-generation antipsychotics risperidone, aripiprazole, quetiapine, sertindole, ziprasidone, paliperidone and olanzapine, have been carried out; modulation of limbic circuitry has been found to be a predictor of treatment response. PET can also be used to predict and monitor likely extrapyramidal side effects from antipsychotic treatment. PET and neuropsychological testing can together also allow the study of putative molecular genetic changes associated with schizophrenia. Advances in the imaging, cognition and molecular genetics are likely to lead to the development of future diagnostics, treatments and novel pharmacological agents.

  20. Embryonic Stem Cell Grafting in Normal and Infarcted Myocardium: Serial Assessment with MR Imaging and PET Dual Detection

    PubMed Central

    Qiao, Hui; Zhang, Hualei; Zheng, Yuanjie; Ponde, Datta E.; Shen, Dinggang; Gao, Fabao; Bakken, Ashley B.; Schmitz, Alexander; Kung, Hank F.; Ferrari, Victor A.; Zhou, Rong

    2009-01-01

    Purpose: To use magnetic resonance (MR) imaging and positron emission tomography (PET) dual detection of cardiac-grafted embryonic stem cells (ESCs) to examine (a) survival and proliferation of ESCs in normal and infarcted myocardium, (b) host macrophage versus grafted ESC contribution to serial MR imaging signal over time, and (c) cardiac function associated with the formation of grafts and whether improvement in cardiac function is related to cardiac differentiation of ESCs. Materials and Methods: All animal procedures were approved by the institutional animal care and use committee. Murine ESCs were stably transfected with a mutant version of herpes simplex virus type 1 thymidine kinase, HSV1-sr39tk, and also were labeled with superparamagnetic iron oxide (SPIO) particles. Cells were injected directly in the border zone of the infarcted heart or in corresponding regions of normal hearts in athymic rats. PET and MR imaging were performed longitudinally for 4 weeks in the same animals. Results: ESCs survived and underwent proliferation in the infarcted and normal hearts, as demonstrated by serial increases in 9-(4-[18F]fluoro-3-hydroxymethylbutyl) guanine PET signals. In parallel, the hypointense areas on MR images at the injection sites decreased over time. Double staining for host macrophages and SPIO particles revealed that the majority of SPIO-containing cells were macrophages at week 4 after injection. Left ventricular ejection fraction increased in the ESC-treated rats but decreased in culture media–treated rats, and border-zone function was preserved in ESC-treated animals; however, cardiac differentiation of ESCs was less than 0.5%. Conclusion: Dual-modality imaging permits complementary information in regard to cell survival and proliferation, graft formation, and effects on cardiac function. © RSNA, 2009 PMID:19244049

  1. Quantitative Evaluation of Atlas-based Attenuation Correction for Brain PET in an Integrated Time-of-Flight PET/MR Imaging System.

    PubMed

    Yang, Jaewon; Jian, Yiqiang; Jenkins, Nathaniel; Behr, Spencer C; Hope, Thomas A; Larson, Peder E Z; Vigneron, Daniel; Seo, Youngho

    2017-02-23

    Purpose To assess the patient-dependent accuracy of atlas-based attenuation correction (ATAC) for brain positron emission tomography (PET) in an integrated time-of-flight (TOF) PET/magnetic resonance (MR) imaging system. Materials and Methods Thirty recruited patients provided informed consent in this institutional review board-approved study. All patients underwent whole-body fluorodeoxyglucose PET/computed tomography (CT) followed by TOF PET/MR imaging. With use of TOF PET data, PET images were reconstructed with four different attenuation correction (AC) methods: PET with patient CT-based AC (CTAC), PET with ATAC (air and bone from an atlas), PET with ATACpatientBone (air and tissue from the atlas with patient bone), and PET with ATACboneless (air and tissue from the atlas without bone). For quantitative evaluation, PET mean activity concentration values were measured in 14 1-mL volumes of interest (VOIs) distributed throughout the brain and statistical significance was tested with a paired t test. Results The mean overall difference (±standard deviation) of PET with ATAC compared with PET with CTAC was -0.69 kBq/mL ± 0.60 (-4.0% ± 3.2) (P < .001). The results were patient dependent (range, -9.3% to 0.57%) and VOI dependent (range, -5.9 to -2.2). In addition, when bone was not included for AC, the overall difference of PET with ATACboneless (-9.4% ± 3.7) was significantly worse than that of PET with ATAC (-4.0% ± 3.2) (P < .001). Finally, when patient bone was used for AC instead of atlas bone, the overall difference of PET with ATACpatientBone (-1.5% ± 1.5) improved over that of PET with ATAC (-4.0% ± 3.2) (P < .001). Conclusion ATAC in PET/MR imaging achieves similar quantification accuracy to that from CTAC by means of atlas-based bone compensation. However, patient-specific anatomic differences from the atlas causes bone attenuation differences and misclassified sinuses, which result in patient-dependent performance variation of ATAC. (©) RSNA, 2017

  2. Characterization of a PET Camera Optimized for ProstateImaging

    SciTech Connect

    Huber, Jennifer S.; Choong, Woon-Seng; Moses, William W.; Qi,Jinyi; Hu, Jicun; Wang, G.C.; Wilson, David; Oh, Sang; Huesman, RonaldH.; Derenzo, Stephen E.

    2005-11-11

    We present the characterization of a positron emission tomograph for prostate imaging that centers a patient between a pair of external curved detector banks (ellipse: 45 cm minor, 70 cm major axis). The distance between detector banks adjusts to allow patient access and to position the detectors as closely as possible for maximum sensitivity with patients of various sizes. Each bank is composed of two axial rows of 20 HR+ block detectors for a total of 80 detectors in the camera. The individual detectors are angled in the transaxial plane to point towards the prostate to reduce resolution degradation in that region. The detectors are read out by modified HRRT data acquisition electronics. Compared to a standard whole-body PET camera, our dedicated-prostate camera has the same sensitivity and resolution, less background (less randoms and lower scatter fraction) and a lower cost. We have completed construction of the camera. Characterization data and reconstructed images of several phantoms are shown. Sensitivity of a point source in the center is 946 cps/mu Ci. Spatial resolution is 4 mm FWHM in the central region.

  3. A pretargeting system for tumor PET imaging and radioimmunotherapy

    PubMed Central

    Kraeber-Bodéré, Françoise; Rousseau, Caroline; Bodet-Milin, Caroline; Frampas, Eric; Faivre-Chauvet, Alain; Rauscher, Aurore; Sharkey, Robert M.; Goldenberg, David M.; Chatal, Jean-François; Barbet, Jacques

    2015-01-01

    Labeled antibodies, as well as their fragments and antibody-derived recombinant constructs, have long been proposed as general vectors to target radionuclides to tumor lesions for imaging and therapy. They have indeed shown promise in both imaging and therapeutic applications, but they have not fulfilled the original expectations of achieving sufficient image contrast for tumor detection or sufficient radiation dose delivered to tumors for therapy. Pretargeting was originally developed for tumor immunoscintigraphy. It was assumed that directly-radiolabled antibodies could be replaced by an unlabeled immunoconjugate capable of binding both a tumor-specific antigen and a small molecular weight molecule. The small molecular weight molecule would carry the radioactive payload and would be injected after the bispecific immunoconjugate. It has been demonstrated that this approach does allow for both antibody-specific recognition and fast clearance of the radioactive molecule, thus resulting in improved tumor-to-normal tissue contrast ratios. It was subsequently shown that pretargeting also held promise for tumor therapy, translating improved tumor-to-normal tissue contrast ratios into more specific delivery of absorbed radiation doses. Many technical approaches have been proposed to implement pretargeting, and two have been extensively documented. One is based on the avidin-biotin system, and the other on bispecific antibodies binding a tumor-specific antigen and a hapten. Both have been studied in preclinical models, as well as in several clinical studies, and have shown improved targeting efficiency. This article reviews the historical and recent preclinical and clinical advances in the use of bispecific-antibody-based pretargeting for radioimmunodetection and radioimmunotherapy of cancer. The results of recent evaluation of pretargeting in PET imaging also are discussed. PMID:25873896

  4. Triple-Modal Imaging of Magnetically-Targeted Nanocapsules in Solid Tumours In Vivo

    PubMed Central

    Bai, Jie; Wang, Julie T.-W.; Rubio, Noelia; Protti, Andrea; Heidari, Hamed; Elgogary, Riham; Southern, Paul; Al-Jamal, Wafa' T.; Sosabowski, Jane; Shah, Ajay M.; Bals, Sara; Pankhurst, Quentin A.; Al-Jamal, Khuloud T.

    2016-01-01

    Triple-modal imaging magnetic nanocapsules, encapsulating hydrophobic superparamagnetic iron oxide nanoparticles, are formulated and used to magnetically target solid tumours after intravenous administration in tumour-bearing mice. The engineered magnetic polymeric nanocapsules m-NCs are ~200 nm in size with negative Zeta potential and shown to be spherical in shape. The loading efficiency of superparamagnetic iron oxide nanoparticles in the m-NC was ~100%. Up to ~3- and ~2.2-fold increase in tumour uptake at 1 and 24 h was achieved, when a static magnetic field was applied to the tumour for 1 hour. m-NCs, with multiple imaging probes (e.g. indocyanine green, superparamagnetic iron oxide nanoparticles and indium-111), were capable of triple-modal imaging (fluorescence/magnetic resonance/nuclear imaging) in vivo. Using triple-modal imaging is to overcome the intrinsic limitations of single modality imaging and provides complementary information on the spatial distribution of the nanocarrier within the tumour. The significant findings of this study could open up new research perspectives in using novel magnetically-responsive nanomaterials in magnetic-drug targeting combined with multi-modal imaging. PMID:26909110

  5. Metal artifact reduction strategies for improved attenuation correction in hybrid PET/CT imaging

    SciTech Connect

    Abdoli, Mehrsima; Dierckx, Rudi A. J. O.; Zaidi, Habib

    2012-06-15

    Metallic implants are known to generate bright and dark streaking artifacts in x-ray computed tomography (CT) images, which in turn propagate to corresponding functional positron emission tomography (PET) images during the CT-based attenuation correction procedure commonly used on hybrid clinical PET/CT scanners. Therefore, visual artifacts and overestimation and/or underestimation of the tracer uptake in regions adjacent to metallic implants are likely to occur and as such, inaccurate quantification of the tracer uptake and potential erroneous clinical interpretation of PET images is expected. Accurate quantification of PET data requires metal artifact reduction (MAR) of the CT images prior to the application of the CT-based attenuation correction procedure. In this review, the origins of metallic artifacts and their impact on clinical PET/CT imaging are discussed. Moreover, a brief overview of proposed MAR methods and their advantages and drawbacks is presented. Although most of the presented MAR methods are mainly developed for diagnostic CT imaging, their potential application in PET/CT imaging is highlighted. The challenges associated with comparative evaluation of these methods in a clinical environment in the absence of a gold standard are also discussed.

  6. Validating and improving CT ventilation imaging by correlating with ventilation 4D-PET/CT using {sup 68}Ga-labeled nanoparticles

    SciTech Connect

    Kipritidis, John Keall, Paul J.; Siva, Shankar; Hofman, Michael S.; Callahan, Jason; Hicks, Rodney J.

    2014-01-15

    Purpose: CT ventilation imaging is a novel functional lung imaging modality based on deformable image registration. The authors present the first validation study of CT ventilation using positron emission tomography with{sup 68}Ga-labeled nanoparticles (PET-Galligas). The authors quantify this agreement for different CT ventilation metrics and PET reconstruction parameters. Methods: PET-Galligas ventilation scans were acquired for 12 lung cancer patients using a four-dimensional (4D) PET/CT scanner. CT ventilation images were then produced by applying B-spline deformable image registration between the respiratory correlated phases of the 4D-CT. The authors test four ventilation metrics, two existing and two modified. The two existing metrics model mechanical ventilation (alveolar air-flow) based on Hounsfield unit (HU) change (V{sub HU}) or Jacobian determinant of deformation (V{sub Jac}). The two modified metrics incorporate a voxel-wise tissue-density scaling (ρV{sub HU} and ρV{sub Jac}) and were hypothesized to better model the physiological ventilation. In order to assess the impact of PET image quality, comparisons were performed using both standard and respiratory-gated PET images with the former exhibiting better signal. Different median filtering kernels (σ{sub m} = 0 or 3 mm) were also applied to all images. As in previous studies, similarity metrics included the Spearman correlation coefficient r within the segmented lung volumes, and Dice coefficient d{sub 20} for the (0 − 20)th functional percentile volumes. Results: The best agreement between CT and PET ventilation was obtained comparing standard PET images to the density-scaled HU metric (ρV{sub HU}) with σ{sub m} = 3 mm. This leads to correlation values in the ranges 0.22 ⩽ r ⩽ 0.76 and 0.38 ⩽ d{sub 20} ⩽ 0.68, with r{sup ¯}=0.42±0.16 and d{sup ¯}{sub 20}=0.52±0.09 averaged over the 12 patients. Compared to Jacobian-based metrics, HU-based metrics lead to statistically significant

  7. Initial Characterization of a Dedicated Breast PET/CT Scanner During Human Imaging

    PubMed Central

    Bowen, Spencer L.; Wu, Yibao; Chaudhari, Abhijit J.; Fu, Lin; Packard, Nathan J.; Burkett, George W.; Yang, Kai; Lindfors, Karen K.; Shelton, David K.; Hagge, Rosalie; Borowsky, Alexander D.; Martinez, Steve R.; Qi, Jinyi; Boone, John M.; Cherry, Simon R.; Badawi, Ramsey D.

    2010-01-01

    We have constructed a dedicated breast PET/CT scanner capable of high-resolution functional and anatomic imaging. Here, we present an initial characterization of scanner performance during patient imaging. Methods The system consisted of a lutetium oxyorthosilicate–based dual–planar head PET camera (crystal size, 3 × 3 × 20 mm) and 768-slice cone-beam CT. The position of the PET heads (separation and height) could be adjusted for varying breast dimensions. For scanning, the patient lay prone on a specialized bed and inserted a single pendent breast through an aperture in the table top. Compression of the breast as used in mammography is not required. PET and CT systems rotate in the coronal plane underneath the patient sequentially to collect fully tomographic datasets. PET images were reconstructed with the fully 3-dimensional maximum a posteriori method, and CT images were reconstructed with the Feldkamp algorithm, then spatially registered and fused for display. Phantom scans were obtained to assess the registration accuracy between PET and CT images and the influence of PET electronics and activity on CT image quality. We imaged 4 women with mammographic findings highly suggestive of breast cancer (breast imaging reporting and data system, category 5) in an ongoing clinical trial. Patients were injected with 18F-FDG and imaged for 12.5 min per breast. From patient data, noise-equivalent counting rates and the singles-to-trues ratio (a surrogate for the randoms fraction) were calculated. Results The average registration error between PET and CT images was 0.18 mm. PET electronics and activity did not significantly affect CT image quality. For the patient trial, biopsy-confirmed cancers were visualized on dedicated breast PET/CT on all patient scans, including the detection of ductal carcinoma in situ in 1 case. The singles-to-trues ratio was found to be inversely correlated with breast volume in the field of view, suggesting that larger breasts trend

  8. DigiPET: sub-millimeter spatial resolution small-animal PET imaging using thin monolithic scintillators

    NASA Astrophysics Data System (ADS)

    España, Samuel; Marcinkowski, Radoslaw; Keereman, Vincent; Vandenberghe, Stefaan; Van Holen, Roel

    2014-07-01

    A new preclinical PET system based on dSiPMs, called DigiPET, is presented. The system is based on thin monolithic scintillation crystals and exhibits superior spatial resolution at low-cost compared to systems based on pixelated crystals. Current dedicated small-rodent PET scanners have a spatial resolution in the order of 1 mm. Most of them have a large footprint, requiring considerable laboratory space. For rodent brain imaging, a PET scanner with sub-millimeter resolution is desired. To achieve this, crystals with a pixel pitch down to 0.5 mm have been used. However, fine pixels are difficult to produce and will render systems expensive. In this work, we present the first results with a high-resolution preclinical PET scanner based on thin monolithic scintillators and a large solid angle. The design is dedicated to rat-brain imaging and therefore has a very compact geometry. Four detectors were placed in a square arrangement with a distance of 34.5 mm between two opposing detector modules, defining a field of view (FOV) of 32 × 32 × 32 mm3. Each detector consists of a thin monolithic LYSO crystal of 32 × 32 × 2 mm3 optically coupled to a digital silicon photomultiplier (dSiPM). Event positioning within each detector was obtained using the maximum likelihood estimation (MLE) method. To evaluate the system performance, we measured the energy resolution, coincidence resolving time (CRT), sensitivity and spatial resolution. The image quality was evaluated by acquiring a hot-rod phantom filled with 18F-FDG and a rat head one hour after an 18F-FDG injection. The MLE yielded an average intrinsic spatial resolution on the detector of 0.54 mm FWHM. We obtained a CRT of 680 ps and an energy resolution of 18% FWHM at 511 keV. The sensitivity and spatial resolution obtained at the center of the FOV were 6.0 cps kBq-1 and 0.7 mm, respectively. In the reconstructed images of the hot-rod phantom, hot rods down to 0.7 mm can be discriminated. In conclusion, a compact PET

  9. Feasibility study of small animal imaging using clinical PET/CT scanner

    NASA Astrophysics Data System (ADS)

    Hsu, Wen-Lin; Chen, Chia-Lin; Wang, Ze-Jing; Wu, Tung-Hsin; Liu, Dai-Wei; Lee, Jason J. S.

    2007-02-01

    The feasibility of small animal imaging using a clinical positron emission tomography/computed tomography (PET/CT) scanner with [F-18]-fluoro-2-deoxy- D-glucose (FDG) was evaluated. Two protocols in PET/CT system, single-mouse high-resolution mode (SHR) and multi-mouse high throughput mode (MHT) protocol were employed to investigate the ability of the scanner and also explored the performance differences between microPET and clinical PET/CT. In this study, we have found that even the clinical PET/CT scanner could not compete with the microPET scanner, especially in spatial resolution; the high-resolution CT image could advance the anatomical information to sub-millimeter level. Besides, CT-based attenuation correction can improve the image uniformity characteristics and quantification accuracy, and the large bore of a human whole-body scanner broadens the possibility of high throughput studies. Considering all the benefits, clinical PET/CT imaging might be a potential alternative for small animal study.

  10. Evolution of bombesin conjugates for targeted PET imaging of tumors.

    PubMed

    Zhang, Hanwen; Abiraj, Keelara; Thorek, Daniel L J; Waser, Beatrice; Smith-Jones, Peter M; Honer, Michael; Reubi, Jean Claude; Maecke, Helmut R

    2012-01-01

    Bombesin receptors are under intense investigation as molecular targets since they are overexpressed in several prevalent solid tumors. We rationally designed and synthesized a series of modified bombesin (BN) peptide analogs to study the influence of charge and spacers at the N-terminus, as well as amino acid substitutions, on both receptor binding affinity and pharmacokinetics. This enabled development of a novel (64/67)Cu-labeled BN peptide for PET imaging and targeted radiotherapy of BN receptor-positive tumors. Our results show that N-terminally positively charged peptide ligands had significantly higher affinity to human gastrin releasing peptide receptor (GRPr) than negatively charged or uncharged ligands (IC(50): 3.2±0.5 vs 26.3±3.5 vs 41.5±2.5 nM). The replacement of Nle(14) by Met, and deletion of D-Tyr(6), further resulted in 8-fold higher affinity. Contrary to significant changes to human GRPr binding, modifications at the N-terminal and at the 6(th), 11(th), and 14(th) position of BN induced only slight influences on affinity to mouse GRPr. [Cu(II)]-CPTA-[βAla(11)] BN(7-14) ([Cu(II)]-BZH7) showed the highest internalization rate into PC-3 cells with relatively slow efflux because of its subnanomolar affinity to GRPr. Interestingly, [(64/67)Cu]-BZH7 also displayed similar affinities to the other 2 human BN receptor subtypes. In vivo studies showed that [(64/67)Cu]-BZH7 had a high accumulation in PC-3 xenografts and allowed for clear-cut visualization of the tumor in PET imaging. In addition, a CPTA-glycine derivative, forming a hippurane-type spacer, enhanced kidney clearance of the radiotracer. These data indicate that the species variation of BN receptor plays an important role in screening radiolabeled BN. As well, the positive charge from the metallated complex at the N-terminal significantly increases affinity to human GRPr. Application of these observations enabled the novel ligand [(64/67)Cu]-BZH7 to clearly visualize PC-3 tumors in vivo

  11. MRI-guided brain PET image filtering and partial volume correction.

    PubMed

    Yan, Jianhua; Lim, Jason Chu-Shern; Townsend, David W

    2015-02-07

    Positron emission tomography (PET) image quantification is a challenging problem due to limited spatial resolution of acquired data and the resulting partial volume effects (PVE), which depend on the size of the structure studied in relation to the spatial resolution and which may lead to over or underestimation of the true tissue tracer concentration. In addition, it is usually necessary to perform image smoothing either during image reconstruction or afterwards to achieve a reasonable signal-to-noise ratio. Typically, an isotropic Gaussian filtering (GF) is used for this purpose. However, the noise suppression is at the cost of deteriorating spatial resolution. As hybrid imaging devices such as PET/MRI have become available, the complementary information derived from high definition morphologic images could be used to improve the quality of PET images. In this study, first of all, we propose an MRI-guided PET filtering method by adapting a recently proposed local linear model and then incorporate PVE into the model to get a new partial volume correction (PVC) method without parcellation of MRI. In addition, both the new filtering and PVC are voxel-wise non-iterative methods. The performance of the proposed methods were investigated with simulated dynamic FDG brain dataset and (18)F-FDG brain data of a cervical cancer patient acquired with a simultaneous hybrid PET/MR scanner. The initial simulation results demonstrated that MRI-guided PET image filtering can produce less noisy images than traditional GF and bias and coefficient of variation can be further reduced by MRI-guided PET PVC. Moreover, structures can be much better delineated in MRI-guided PET PVC for real brain data.

  12. MRI-guided brain PET image filtering and partial volume correction

    NASA Astrophysics Data System (ADS)

    Yan, Jianhua; Chu-Shern Lim, Jason; Townsend, David W.

    2015-02-01

    Positron emission tomography (PET) image quantification is a challenging problem due to limited spatial resolution of acquired data and the resulting partial volume effects (PVE), which depend on the size of the structure studied in relation to the spatial resolution and which may lead to over or underestimation of the true tissue tracer concentration. In addition, it is usually necessary to perform image smoothing either during image reconstruction or afterwards to achieve a reasonable signal-to-noise ratio. Typically, an isotropic Gaussian filtering (GF) is used for this purpose. However, the noise suppression is at the cost of deteriorating spatial resolution. As hybrid imaging devices such as PET/MRI have become available, the complementary information derived from high definition morphologic images could be used to improve the quality of PET images. In this study, first of all, we propose an MRI-guided PET filtering method by adapting a recently proposed local linear model and then incorporate PVE into the model to get a new partial volume correction (PVC) method without parcellation of MRI. In addition, both the new filtering and PVC are voxel-wise non-iterative methods. The performance of the proposed methods were investigated with simulated dynamic FDG brain dataset and 18F-FDG brain data of a cervical cancer patient acquired with a simultaneous hybrid PET/MR scanner. The initial simulation results demonstrated that MRI-guided PET image filtering can produce less noisy images than traditional GF and bias and coefficient of variation can be further reduced by MRI-guided PET PVC. Moreover, structures can be much better delineated in MRI-guided PET PVC for real brain data.

  13. 68Ga-PSMA PET/CT Imaging in Multiple Myeloma.

    PubMed

    Sasikumar, Arun; Joy, Ajith; Pillai, M R A; Nanabala, Raviteja; Thomas, Boben

    2017-02-01

    The potential applications of Ga-labeled prostate-specific membrane antigen (PSMA) PET/CT in the imaging of prostate cancer are now well established. A few case reports regarding the potential use of Ga-PSMA PET/CT in nonprostate cancer malignancies are also published. Apparently, the tumor neoangiogenesis is the mechanism attributed to increased Ga-PSMA uptake in the tumor sites in nonprostatic malignancies. We describe the use of Ga-PSMA PET/CT in imaging multiple myeloma. The intense Ga-PSMA avidity of the lesions also opens up the possibility of theranostics with Lu-PSMA.

  14. Simultaneous reconstruction of the activity image and registration of the CT image in TOF-PET

    NASA Astrophysics Data System (ADS)

    Rezaei, Ahmadreza; Michel, Christian; Casey, Michael E.; Nuyts, Johan

    2016-02-01

    Previously, maximum-likelihood methods have been proposed to jointly estimate the activity image and the attenuation image or the attenuation sinogram from time-of-flight (TOF) positron emission tomography (PET) data. In this contribution, we propose a method that addresses the possible alignment problem of the TOF-PET emission data and the computed tomography (CT) attenuation data, by combining reconstruction and registration. The method, called MLRR, iteratively reconstructs the activity image while registering the available CT-based attenuation image, so that the pair of activity and attenuation images maximise the likelihood of the TOF emission sinogram. The algorithm is slow to converge, but some acceleration could be achieved by using Nesterov’s momentum method and by applying a multi-resolution scheme for the non-rigid displacement estimation. The latter also helps to avoid local optima, although convergence to the global optimum cannot be guaranteed. The results are evaluated on 2D and 3D simulations as well as a respiratory gated clinical scan. Our experiments indicate that the proposed method is able to correct for possible misalignment of the CT-based attenuation image, and is therefore a very promising approach to suppressing attenuation artefacts in clinical PET/CT. When applied to respiratory gated data of a patient scan, it produced deformations that are compatible with breathing motion and which reduced the well known attenuation artefact near the dome of the liver. Since the method makes use of the energy-converted CT attenuation image, the scale problem of joint reconstruction is automatically solved.

  15. Thermophotonic lock-in imaging: a novel early caries detection and imaging modality

    NASA Astrophysics Data System (ADS)

    Tabatabaei, Nima; Mandelis, Andreas; Amaechi, Bennett T.

    2011-03-01

    Using photothermal wave principles and as an extension to the frequency-domain photothermal radiometry, a novel dental imaging modality, thermophotonic lock-in imaging (TPLI), is introduced. In order to assess the capabilities of the proposed methodology samples with natural and artificially-generated caries were examined and the results were compared with the destructive transverse microradiography density profiles. It was found that the increased light scattering and absorption within early carious lesions increases the thermal-wave amplitude and shifts the thermal-wave centroid, producing contrast between the carious lesion and the intact enamel in both amplitude and phase images. Phase images are emissivity normalized and therefore insensitive to the presence of stain. Amplitude images provide integrated information from deeper enamel regions. It was concluded that the results of our non-invasive, non-contacting imaging methodology exhibit significantly higher sensitivity to very early demineralization than dental radiographs and are in agreement with the destructive transverse microradiography mineral density profiles.

  16. Algorithm for lung cancer detection based on PET/CT images

    NASA Astrophysics Data System (ADS)

    Saita, Shinsuke; Ishimatsu, Keita; Kubo, Mitsuru; Kawata, Yoshiki; Niki, Noboru; Ohtsuka, Hideki; Nishitani, Hiromu; Ohmatsu, Hironobu; Eguchi, Kenji; Kaneko, Masahiro; Moriyama, Noriyuki

    2009-02-01

    The five year survival rate of the lung cancer is low with about twenty-five percent. In addition it is an obstinate lung cancer wherein three out of four people die within five years. Then, the early stage detection and treatment of the lung cancer are important. Recently, we can obtain CT and PET image at the same time because PET/CT device has been developed. PET/CT is possible for a highly accurate cancer diagnosis because it analyzes quantitative shape information from CT image and FDG distribution from PET image. However, neither benign-malignant classification nor staging intended for lung cancer have been established still enough by using PET/CT images. In this study, we detect lung nodules based on internal organs extracted from CT image, and we also develop algorithm which classifies benignmalignant and metastatic or non metastatic lung cancer using lung structure and FDG distribution(one and two hour after administering FDG). We apply the algorithm to 59 PET/CT images (malignant 43 cases [Ad:31, Sq:9, sm:3], benign 16 cases) and show the effectiveness of this algorithm.

  17. Contribution of nonattenuation-corrected images on FDG-PET/CT in the assessment of solitary pulmonary nodules.

    PubMed

    Şahin, Ertan; Kara, Ahmet; Elboğa, Umut

    2016-12-01

    In this study, we aim to determine the diagnostic performance of nonattenuation-corrected (NAC) and attenuation-corrected (AC) FDG-PET/CT images in the assessment of solitary pulmonary nodule (SPN). We reviewed the images of 41 patients who underwent FDG-PET/CT to diagnose SPNs. The visual analysis of FDG uptake intensity in SPN on AC and NAC PET images was made using a four-point score from 1 to 4 on both AC and NAC PET images. The cutoff value of SUVmax and visual uptake scores for malignancy were defined as ≥2.5 and ≥3, respectively. The significant visual uptake (≥2 visual point score) on AC and NAC PET images was considered to be positive 18F-FDG PET findings for lesion detectability. The sensitivity, specificity and diagnostic accuracy were calculated for AC and NAC PET images. Based on the histopathology and imaging data, 22 of the SPNs (54 %) were malignant and 19 of them (46 %) were benign. The sensitivity and NPV were found to be 100 % in the detection of SPNs for AC and NAC PET images. For all SPNs and SPNs ≤2 cm, NAC PET image had a higher diagnostic performance for the SPN characterization as malignant or benign, when compared with AC PET image. The success rates of AC and NAC PET images were found to be similar for the detection of SPNs. NAC PET image had a higher diagnostic performance for the SPN characterization. It is thought that NAC PET image may provide additional contributions for characterization of SPNs.

  18. Comparison of Ductoscopy, Galactography, and Imaging Modalities for the Evaluation of Intraductal Lesions: A Critical Review

    PubMed Central

    Sarica, Ozgur; Ozturk, Enis; Demirkurek, Huseyin C.; Uluc, Fatih

    2013-01-01

    Summary Background Today, in cases of nipple discharge of unclear origin, the abundance of diagnostic procedures – a, diagnostic dilemma’ – becomes apparent, because unequivocal indications and a current, standardized examination sequence are presently not available. The diagnostic workup of patients with nipple discharge usually includes the clinical history, physical examination, mammography, ultrasonography, galactography, and nipple discharge cytology, but not ductoscopy. Methods In this review we analyze and discuss the possible role of ductoscopy in evaluating intraductal pathologies and its combined use with diagnostic imaging modalities. For this purpose, we reviewed and compared the results of the radiological, pathological, and surgical studies independently. Conclusions Currently, there is no solitary accurate modality to reach our definitive purpose. Being aware of the capability of each diagnostic modality may take us closer to our target. Therefore, adjunct and appropriate use of multiple imaging modalities and ductoscopy is necessary to evaluate patients with nipple discharge. PMID:24415988

  19. Image Quality Performance Measurement of the microPET Focus 120

    NASA Astrophysics Data System (ADS)

    Ballado, Fernando Trejo; López, Nayelli Ortega; Flores, Rafael Ojeda; Ávila-Rodríguez, Miguel A.

    2010-12-01

    The aim of this work is to evaluate the characteristics involved in the image reconstruction of the microPET Focus 120. For this evaluation were used two different phantoms; a miniature hot-rod Derenzo phantom and a National Electrical Manufacturers Association (NEMA) NU4-2008 image quality (IQ) phantom. The best image quality was obtained when using OSEM3D as the reconstruction method reaching a spatial resolution of 1.5 mm with the Derenzo phantom filled with 18F. Image quality test results indicate a superior image quality for the Focus 120 when compared to previous microPET models.

  20. PET imaging with the non-pure positron emitters: 55Co, 86Y and 124I

    NASA Astrophysics Data System (ADS)

    Braad, P. E. N.; Hansen, S. B.; Thisgaard, H.; Høilund-Carlsen, P. F.

    2015-05-01

    PET/CT with non-pure positron emitters is a highly valuable tool in immuno-PET and for pretherapeutic dosimetry. However, imaging is complicated by prompt gamma coincidences (PGCs) that add an undesired background activity to the images. Time-of-flight (TOF) reconstruction improves lesion detectability in 18F-PET and can potentially also improve the signal-to-noise ratio in images acquired with non-pure positron emitters. Using the GE Discovery 690 PET/CT system, we evaluated the image quality with 55Co, 86Y and 124I, and the effect of PGC-correction and TOF-reconstruction on image quality and quantitation in a series of phantom studies. PET image quality and quantitation for all isotopes were significantly affected by PGCs. The effect was most severe with 86Y, and less, but comparable, with 55Co and 124I. PGC-correction improved the image quality and the quantitation accuracy dramatically for all isotopes, especially when the activity was limited to a few hot lesions in a warm background. In imaging situations, where high levels of activity were present in the background, activity concentrations were overestimated. TOF-reconstruction improved image quality in isolated lesions but worsened the accuracy of quantitation and uniformity in homogeneous activity distributions. Better modelling of PGCs in the scatter correction can potentially improve the situation.

  1. OpenPET: A Flexible Electronics System for Radiotracer Imaging

    PubMed Central

    Moses, W. W.; Buckley, S.; Vu, C.; Peng, Q.; Pavlov, N.; Choong, W.-S.; Wu, J.; Jackson, C.

    2011-01-01

    We present the design for OpenPET, an electronics readout system designed for prototype radiotracer imaging instruments. The critical requirements are that it has sufficient performance, channel count, channel density, and power consumption to service a complete camera, and yet be simple, flexible, and customizable enough to be used with almost any detector or camera design. An important feature of this system is that each analog input is processed independently. Each input can be configured to accept signals of either polarity as well as either differential or ground referenced signals. Each signal is digitized by a continuously sampled ADC, which is processed by an FPGA to extract pulse height information. A leading edge discriminator creates a timing edge that is “time stamped” by a TDC implemented inside the FPGA. This digital information from each channel is sent to an FPGA that services 16 analog channels, and information from multiple channels is processed by this FPGA to perform logic for crystal lookup, DOI calculation, calibration, etc. As all of this processing is controlled by firmware and software, it can be modified / customized easily. The system is open source, meaning that all technical data (specifications, schematics and board layout files, source code, and instructions) will be publicly available. PMID:21297894

  2. Imaging Modalities Relevant to Intracranial Pressure Assessment in Astronauts: A Case-Based Discussion

    NASA Technical Reports Server (NTRS)

    Sargsyan, Ashot E.; Kramer, Larry A.; Hamilton, Douglas R.; Hamilton, Douglas R.; Fogarty, Jennifer; Polk, J. D.

    2010-01-01

    Introduction: Intracranial pressure (ICP) elevation has been inferred or documented in a number of space crewmembers. Recent advances in noninvasive imaging technology offer new possibilities for ICP assessment. Most International Space Station (ISS) partner agencies have adopted a battery of occupational health monitoring tests including magnetic resonance imaging (MRI) pre- and postflight, and high-resolution sonography of the orbital structures in all mission phases including during flight. We hypothesize that joint consideration of data from the two techniques has the potential to improve quality and continuity of crewmember monitoring and care. Methods: Specially designed MRI and sonographic protocols were used to image eyes and optic nerves (ON) including the meningeal sheaths. Specific crewmembers multi-modality imaging data were analyzed to identify points of mutual validation as well as unique features of complementary nature. Results and Conclusion: Magnetic resonance imaging (MRI) and high-resolution sonography are both tomographic methods, however images obtained by the two modalities are based on different physical phenomena and use different acquisition principles. Consideration of the images acquired by these two modalities allows cross-validating findings related to the volume and fluid content of the ON subarachnoid space, shape of the globe, and other anatomical features of the orbit. Each of the imaging modalities also has unique advantages, making them complementary techniques.

  3. Current status of PET in breast cancer imaging, staging, and therapy.

    PubMed

    Wahl, R L

    2001-07-01

    The exact roles of PET in the imaging management of patients with known or suspected breast cancer are still in evolution. For assessing primary lesions, it is sometimes possible with PET to detect cancers occult on standard methods. This could be useful in high-risk patient populations, but in dense breasts, background FDG uptake is often higher than in women with fatty breasts, making identification of lesions < 1 cm in size improbable with current technologies. Distinguishing malignant from benign primary breast disease would seem better addressed by biopsy. With a positive predictive value of FDG PET for cancer over 96%, any FDG-avid breast lesion is highly suspicious and merits biopsy. Although PET in theory should be useful for depicting multifocal disease before surgery, the limitations in detecting small lesions in the breast limit the contribution of PET at present. It is most likely that PET will have a greater role in depicting primary breast lesions as dedicated PET imaging devices for the breast evolve. For axillary and internal mammary nodal staging, results with FDG PET are variable. Small nodal metastases < or = 5 mm will be missed by PET, whereas larger ones are more likely to be detected. PET can depict internal mammary nodes, but the accuracy of the method in this setting is not known, nor is there consensus on how identifying internal mammary node metastases will change treatment. Based on the available data, for pT1 breast lesions, PET, if negative, is not an adequate replacement for sentinel node surgery or axillary dissection. Results from the multicenter trial will be of great interest. Clearly PET can stage metastatic disease well. Bone scans with 18F- are exquisitely sensitive for metastases, and FDG is also very good. However, FDG PET can miss some blastic metastases to bone so at present FDG is not capable of excluding the presence of bone metastases. PET seems very well suited to detecting recurrences in soft tissues and the brachial

  4. Molecular imaging of late somatostatin receptor-positive metastases of renal cell carcinoma in the pancreas by 68Ga DOTATOC PET/CT: a rare differential diagnosis to multiple primary pancreatic neuroendocrine tumors.

    PubMed

    Peter, Luisa; Sänger, Jörg; Hommann, Merten; Baum, Richard Paul; Kaemmerer, Daniel

    2014-08-01

    Ga somatostatin receptor PET/CT, currently the most sensitive imaging modality for well-differentiated neuroendocrine tumors, is based on the molecular imaging of somatostatin receptors (SSTRs) that are expressed in different tumor entities such as neuroendocrine neoplasms, lymphomas, meningiomas, or renal cell cancer (RCC). Most neuroendocrine neoplasms show a high expression of SSTR subtypes 2A and 5, whereas the overexpression of SSTR2A in RCC is mainly seen in peritumoral vessels. Here we report a case with strongly SSTR-positive pancreatic lesions detected by Ga DOTATOC PET/CT, which histologically turned out to be ultralate metastases of a RCC.

  5. Fully integrated optical coherence tomography, ultrasound, and indocyanine green-based fluorescence tri-modality system for intravascular imaging

    PubMed Central

    Li, Yan; Jing, Joseph; Qu, Yueqiao; Miao, Yusi; Zhang, Buyun; Ma, Teng; Yu, Mingyue; Zhou, Qifa; Chen, Zhongping

    2017-01-01

    We present a tri-modality imaging system and fully integrated tri-modality probe for intravascular imaging. The tri-modality imaging system is able to simultaneously acquire optical coherence tomography (OCT), ultrasound (US), and fluorescence imaging. Moreover, for fluorescence imaging, we used the FDA-approved indocyanine green (ICG) dye as the contrast agent to target lipid-loaded macrophages. We conducted imaging from a male New Zealand white rabbit to evaluate the performance of the tri-modality system. In addition, tri-modality images of rabbit aortas were correlated with hematoxylin and eosin (H&E) histology to check the measurement accuracy. The fully integrated miniature tri-modality probe, together with the use of ICG dye suggest that the system is of great potential for providing a more accurate assessment of vulnerable plaques in clinical applications. PMID:28271001

  6. Safe storage and multi-modal search for medical images.

    PubMed

    Kommeri, Jukka; Niinimäki, Marko; Müller, Henning

    2011-01-01

    Modern hospitals produce enormous amounts of data in all departments, from images, to lab results, medication use, and release letters. Since several years these data are most often produced in digital form, making them accessible for researchers to optimize the outcome of care process and analyze all available data across patients. The Geneva University Hospitals (HUG) are no exception with its daily radiology department's output of over 140'000 images in 2010, with a majority of them being tomographic slices. In this paper we introduce tools for uploading and accessing DICOM images and associated metadata in a secure Grid storage. These data are made available for authorized persons using a Grid security framework, as security is a main problem in secondary use of image data, where images are to be stored outside of the clinical image archive. Our tool combines the security and metadata access of a Grid middleware with the visual search that uses GIFT.

  7. Programmable aperture microscopy: A computational method for multi-modal phase contrast and light field imaging

    NASA Astrophysics Data System (ADS)

    Zuo, Chao; Sun, Jiasong; Feng, Shijie; Zhang, Minliang; Chen, Qian

    2016-05-01

    We demonstrate a simple and cost-effective programmable aperture microscope to realize multi-modal computational imaging by integrating a programmable liquid crystal display (LCD) into a conventional wide-field microscope. The LCD selectively modulates the light distribution at the rear aperture of the microscope objective, allowing numerous imaging modalities, such as bright field, dark field, differential phase contrast, quantitative phase imaging, multi-perspective imaging, and full resolution light field imaging to be achieved and switched rapidly in the same setup, without requiring specialized hardwares and any moving parts. We experimentally demonstrate the success of our method by imaging unstained cheek cells, profiling microlens array, and changing perspective views of thick biological specimens. The post-exposure refocusing of a butterfly mouthpart and RFP-labeled dicot stem cross-section is also presented to demonstrate the full resolution light field imaging capability of our system for both translucent and fluorescent specimens.

  8. Thermographic Assessment of a Vascular Malformation of the Hand: A New Imaging Modality

    PubMed Central

    Hardwicke, Joseph T.; Titley, O. Garth

    2016-01-01

    Vascular malformations of the hand are rare. Angiography is the current Gold Standard imaging modality. Thermal imaging is an emerging noninvasive, noncontact technology that does not require intravenous contrast agents. We present the case of a patient with an arteriovenous malformation affecting the hand in which thermal imaging has been used as an adjunct to capture baseline images to allow monitoring of progression. We suggest that thermal imaging provides an adjunct that can be used in addition to clinical examination and/or angiography for the diagnosis and routine follow-up of conservatively managed arteriovenous malformations, to monitor progression or vascular steal, and also for recording recurrence after surgical excision for which there is known to be a significant incidence. With the benefit of being a noninvasive imaging modality that does not require intravenous contrast, or ionizing radiation exposure, office-based thermal imaging may become commonplace. PMID:27195175

  9. Twelve automated thresholding methods for segmentation of PET images: a phantom study

    NASA Astrophysics Data System (ADS)

    Prieto, Elena; Lecumberri, Pablo; Pagola, Miguel; Gómez, Marisol; Bilbao, Izaskun; Ecay, Margarita; Peñuelas, Iván; Martí-Climent, Josep M.

    2012-06-01

    Tumor volume delineation over positron emission tomography (PET) images is of great interest for proper diagnosis and therapy planning. However, standard segmentation techniques (manual or semi-automated) are operator dependent and time consuming while fully automated procedures are cumbersome or require complex mathematical development. The aim of this study was to segment PET images in a fully automated way by implementing a set of 12 automated thresholding algorithms, classical in the fields of optical character recognition, tissue engineering or non-destructive testing images in high-tech structures. Automated thresholding algorithms select a specific threshold for each image without any a priori spatial information of the segmented object or any special calibration of the tomograph, as opposed to usual thresholding methods for PET. Spherical 18F-filled objects of different volumes were acquired on clinical PET/CT and on a small animal PET scanner, with three different signal-to-background ratios. Images were segmented with 12 automatic thresholding algorithms and results were compared with the standard segmentation reference, a threshold at 42% of the maximum uptake. Ridler and Ramesh thresholding algorithms based on clustering and histogram-shape information, respectively, provided better results that the classical 42%-based threshold (p < 0.05). We have herein demonstrated that fully automated thresholding algorithms can provide better results than classical PET segmentation tools.

  10. Twelve automated thresholding methods for segmentation of PET images: a phantom study.

    PubMed

    Prieto, Elena; Lecumberri, Pablo; Pagola, Miguel; Gómez, Marisol; Bilbao, Izaskun; Ecay, Margarita; Peñuelas, Iván; Martí-Climent, Josep M

    2012-06-21

    Tumor volume delineation over positron emission tomography (PET) images is of great interest for proper diagnosis and therapy planning. However, standard segmentation techniques (manual or semi-automated) are operator dependent and time consuming while fully automated procedures are cumbersome or require complex mathematical development. The aim of this study was to segment PET images in a fully automated way by implementing a set of 12 automated thresholding algorithms, classical in the fields of optical character recognition, tissue engineering or non-destructive testing images in high-tech structures. Automated thresholding algorithms select a specific threshold for each image without any a priori spatial information of the segmented object or any special calibration of the tomograph, as opposed to usual thresholding methods for PET. Spherical (18)F-filled objects of different volumes were acquired on clinical PET/CT and on a small animal PET scanner, with three different signal-to-background ratios. Images were segmented with 12 automatic thresholding algorithms and results were compared with the standard segmentation reference, a threshold at 42% of the maximum uptake. Ridler and Ramesh thresholding algorithms based on clustering and histogram-shape information, respectively, provided better results that the classical 42%-based threshold (p < 0.05). We have herein demonstrated that fully automated thresholding algorithms can provide better results than classical PET segmentation tools.

  11. A comparison of noninvasive imaging modalities in the melanoma patient

    SciTech Connect

    Doiron, M.J.; Bernardino, M.E.

    1981-06-01

    The results of radionuclide (RN) liver scans, computed tomography (CT), and ultrasonography (US) were compared in 163 patients. Thirty-eight patients had all three studies, while ten were examined by CT and RN liver scans. One hundred fifteen patients had only US and RN studies. Radionuclide liver scanning demonstrated more false positive and negative studies than CT or US. Also, CT and US demonstrated more areas of metastasis during a single examination than RN liver scans. Ultrasonography displayed roughly the same accuracy of CT when a technically adequate examination was obtained. However, US was hampered by technically inadequate studies in 19% of 153 patients because of interfering intestinal gas. Computed tomography proved the most accurate and reliable modality in 48 patients.

  12. Hybrid registration of PET/CT in thoracic region with pre-filtering PET sinogram

    NASA Astrophysics Data System (ADS)

    Mokri, S. S.; Saripan, M. I.; Marhaban, M. H.; Nordin, A. J.; Hashim, S.

    2015-11-01

    The integration of physiological (PET) and anatomical (CT) images in cancer delineation requires an accurate spatial registration technique. Although hybrid PET/CT scanner is used to co-register these images, significant misregistrations exist due to patient and respiratory/cardiac motions. This paper proposes a hybrid feature-intensity based registration technique for hybrid PET/CT scanner. First, simulated PET sinogram was filtered with a 3D hybrid mean-median before reconstructing the image. The features were then derived from the segmented structures (lung, heart and tumor) from both images. The registration was performed based on modified multi-modality demon registration with multiresolution scheme. Apart from visual observations improvements, the proposed registration technique increased the normalized mutual information index (NMI) between the PET/CT images after registration. All nine tested datasets show marked improvements in mutual information (MI) index than free form deformation (FFD) registration technique with the highest MI increase is 25%.

  13. Insights into dendritic cell function using advanced imaging modalities.

    PubMed

    Vyas, Jatin M

    2012-11-15

    The application of advanced imaging techniques to fundamental questions in immunology has provided insight into dendritic cell function and has challenged dogma created using static imaging of lymphoid tissue. The history of dendritic cell biology has a storied past and is tightly linked to imaging. The development of imaging techniques that emphasize live cell imaging in situ has provided not only breath-taking movies, but also novel insights into the importance of spatiotemporal relationships between antigen presenting cells and T cells. This review serves to provide a primer on two-photon microscopy, TIRF microscopy, spinning disk confocal microscopy and optical trapping and provides selective examples of insights gained from these tools on dendritic cell biology.

  14. PET/MR in children. Initial clinical experience in paediatric oncology using an integrated PET/MR scanner.

    PubMed

    Hirsch, Franz Wolfgang; Sattler, Bernhard; Sorge, Ina; Kurch, Lars; Viehweger, Adrian; Ritter, Lutz; Werner, Peter; Jochimsen, Thies; Barthel, Henryk; Bierbach, Uta; Till, Holger; Sabri, Osama; Kluge, Regine

    2013-07-01

    Use of PET/MR in children has not previously been reported, to the best of our knowledge. Children with systemic malignancies may benefit from the reduced radiation exposure offered by PET/MR. We report our initial experience with PET/MR hybrid imaging and our current established sequence protocol after 21 PET/MR studies in 15 children with multifocal malignant diseases. The effective dose of a PET/MR scan was only about 20% that of the equivalent PET/CT examination. Simultaneous acquisition of PET and MR data combines the advantages of the two previously separate modalities. Furthermore, the technique also enables whole-body diffusion-weighted imaging (DWI) and statements to be made about the biological cellularity and nuclear/cytoplasmic ratio of tumours. Combined PET/MR saves time and resources. One disadvantage of PET/MR is that in order to have an effect, a significantly longer examination time is needed than with PET/CT. In our initial experience, PET/MR has turned out to be an unexpectedly stable and reliable hybrid imaging modality, which generates a complementary diagnostic study of great additional value.

  15. Growing applications of FDG PET-CT imaging in non-oncologic conditions

    PubMed Central

    Zhuang, Hongming; Codreanu, Ion

    2015-01-01

    Abstract As the number of clinical applications of 2-[fluorine 18]fluoro-2-deoxy-D-glucose (FDG) positron emission tomography/computed tomography (PET-CT) grows, familiarity with the conditions that can be diagnosed by this modality and when relevant pieces of additional information can be obtained becomes increasingly important for both requesting physicians and nuclear medicine physicians or radiologists who interpret the findings. Apart from its heavy use in clinical oncology, FDG PET-CT is widely used in a variety of non-oncologic conditions interconnecting to such disciplines as general internal medicine, infectious diseases, cardiology, neurology, surgery, traumatology, orthopedics, pediatrics, endocrinology, rheumatology, psychiatry, neuropsychology, and cognitive neuroscience. The aim of this review was to summarize the current evidence of FDG PET-CT applications in evaluating non-oncologic pathologies and the relevant information it can add to achieve a final diagnosis. PMID:26060443

  16. Approaches using molecular imaging technology -- use of PET in clinical microdose studies.

    PubMed

    Wagner, Claudia C; Langer, Oliver

    2011-06-19

    Positron emission tomography (PET) imaging uses minute amounts of radiolabeled drug tracers and thereby meets the criteria for clinical microdose studies. The advantage of PET, when compared to other analytical methods used in microdose studies, is that the pharmacokinetics (PK) of a drug can be determined in the tissue targeted for drug treatment. PET microdosing already offers interesting applications in clinical oncology and in the development of central nervous system pharmaceuticals and is extending its range of application to many other fields of pharmaceutical medicine. Although requirements for preclinical safety testing for microdose studies have been cut down by regulatory authorities, radiopharmaceuticals increasingly need to be produced under good manufacturing practice (GMP) conditions, which increases the costs of PET microdosing studies. Further challenges in PET microdosing include combining PET with other ultrasensitive analytical methods, such as accelerator mass spectrometry (AMS), to gain plasma PK data of drugs, beyond the short PET examination periods. Finally, conducting clinical PET studies with radiolabeled drugs both at micro- and therapeutic doses is encouraged to answer the question of dose linearity in clinical microdosing.

  17. Approaches using molecular imaging technology - use of PET in clinical microdose studies§

    PubMed Central

    Wagner, Claudia C; Langer, Oliver

    2013-01-01

    Positron emission tomography (PET) imaging uses minute amounts of radiolabeled drug tracers and thereby meets the criteria for clinical microdose studies. The advantage of PET, when compared to other analytical methods used in microdose studies, is that the pharmacokinetics (PK) of a drug can be determined in the tissue targeted for drug treatment. PET microdosing already offers interesting applications in clinical oncology and in the development of central nervous system pharmaceuticals and is extending its range of application to many other fields of pharmaceutical medicine. Although requirements for preclinical safety testing for microdose studies have been cut down by regulatory authorities, radiopharmaceuticals increasingly need to be produced under good manufacturing practice (GMP) conditions, which increases the costs of PET microdosing studies. Further challenges in PET microdosing include combining PET with other ultrasensitive analytical methods, such as accelerator mass spectrometry (AMS), to gain plasma PK data of drugs, beyond the short PET examination periods. Finally, conducting clinical PET studies with radiolabeled drugs both at micro- and therapeutic doses is encouraged to answer the question of dose linearity in clinical microdosing. PMID:20887762

  18. High Resolution PET Imaging Probe for the Detection, Molecular Characterization and Treatment Monitoring of Prostate Cancer

    DTIC Science & Technology

    2012-07-01

    recognized in both emission modalities, SPECT and PET. Compton camera is a subspecies of SPECT, where a silicon based scatter as a MR compatible part...exploit their advantages while compensat- ing for their drawbacks. Two specific arrangements are presented, a Compton camera with silicon detectors [4...direction of the field due to circular motion of the positrons. A brief summary of the study will be presented. 2. Compton camera Compton camera is a

  19. New magnetic resonance imaging modalities for Crohn disease.

    PubMed

    Yacoub, Joseph H; Oto, Aytekin

    2014-02-01

    Magnetic resonance (MR) enterography has an increasing role in the evaluation of the small bowel in patients with Crohn disease. MR enterography is accurate for disease assessment and can influence the choice of therapy. Functional sequences may increase the role of MR enterography in Crohn disease. Techniques such as high-resolution MR enterography, diffusion-weighted imaging, dynamic contrast-enhanced MR imaging, magnetization transfer, and MR motility imaging may allow better assessment of disease extent, activity, and severity. Quantitative analysis using these advanced techniques as well as the standard techniques may provide methods for evaluating and following the disease in the future.

  20. Imaging Modality of Choice for Pre-Operative Cochlear Imaging: HRCT vs. MRI Temporal Bone

    PubMed Central

    Solanki, Rajendra N.; Shah, Dipali C.; Vishwakarma, Rajesh; Kumar, Sandeep

    2016-01-01

    Introduction Congenital inner ear malformations occur as a result of the arrest or aberrance of inner ear development due to the heredity, gene mutation or other factors. Ever since the availability of cochlear implants, pre-operative evaluation by imaging of temporal bone has gained much attention. Precise selection of the candidate for cochlear implant dependent on preoperative radiological investigations. Only CT (Computed Tomography) and MRI (Magnetic Resonance Imaging) can provide a better picture of anatomy and pathology. Aim To compare pre-operative imaging findings of both MRI and High Resolution Computed Tomography (HRCT) temporal bone and to find the best modality of choice in patients with bilateral profound Sensorineural Hearing Loss (SNHL). Materials and Methods This was a prospective, longitudinal, observational study conducted between June 2010 to November 2012. A total of 144 temporal bones were evaluated in 72 children with bilateral profound SNHL with congenital inner ear malformations. Each temporal bone was considered as a single case (144 cases). All the patients underwent HRCT and high field MRI study. MRI study included T2 W axial 3D FIESTA (Fast Imaging Employing Steady-state Acquisition) sequence. Anatomic abnormalities in each temporal bone were described and noted. For complete and better evaluation of Vestibulo-Cochlear Nerve (VCN) additional 3D oblique parasagittal view was taken perpendicular to the internal auditory canal with a small Field Of View (FOV). Results HRCT and MRI allowed accurate detection of inner ear malformations in children with bilateral SNHL. Majority of the patients presented with multiple structural abnormalities of inner ear. The common pathologies detected in the study were semicircular canal abnormality (89/144) followed by cochlear abnormalities (39/144). Most common cochlear abnormality was Mondini’s deformity (14/144). MRI demonstrated absent of vestibulo-cochlear nerve in 15 cases. Conclusion Few

  1. Comparison of Whole-Body 18F FDG PET/MR Imaging and Whole-Body 18F FDG PET/CT in Terms of Lesion Detection and Radiation Dose in Patients with Breast Cancer

    PubMed Central

    Melsaether, Amy N.; Raad, Roy A.; Pujara, Akshat C.; Ponzo, Fabio D.; Pysarenko, Kristine M.; Jhaveri, Komal; Babb, James S.; Sigmund, Eric E.; Kim, Sungheon G.; Moy, Linda A.

    2016-01-01

    Purpose To compare fluorine 18 (18F) fluorodeoxyglucose (FDG) combined positron emission tomography (PET) and magnetic resonance (MR) imaging with 18F FDG combined PET and computed tomography (CT) in terms of organ-specific metastatic lesion detection and radiation dose in patients with breast cancer. Materials and Methods From July 2012 to October 2013, this institutional review board–approved HIPAA-compliant prospective study included 51 patients with breast cancer (50 women; mean age, 56 years; range, 32–76 years; one man; aged 70 years) who completed PET/MR imaging with diffusion-weighted and contrast material–enhanced sequences after unenhanced PET/CT. Written informed consent for study participation was obtained. Two independent readers for each modality recorded site and number of lesions. Imaging and clinical follow-up, with consensus in two cases, served as the reference standard. Results There were 242 distant metastatic lesions in 30 patients, 18 breast cancers in 17 patients, and 19 positive axillary nodes in eight patients. On a per-patient basis, PET/MR imaging with diffusion-weighted and contrast-enhanced sequences depicted distant (30 of 30 [100%] for readers 1 and 2) and axillary (eight of eight [100%] for reader 1, seven of eight [88%] for reader 2) metastatic disease at rates similar to those of unenhanced PET/CT (distant metastatic disease: 28 of 29 [96%] for readers 3 and 4, P = .50; axillary metastatic disease: seven of eight [88%] for readers 3 and 4, P > .99) and outperformed PET/CT in the detection of breast cancer (17 of 17 [100%] for readers 1 and 2 vs 11 of 17 [65%] for reader 3 and 10 of 17 [59%] for reader 4; P < .001). PET/MR imaging showed increased sensitivity for liver (40 of 40 [100%] for reader 1 and 32 of 40 [80%] for reader 2 vs 30 of 40 [75%] for reader 3 and 28 of 40 [70%] for reader 4; P < .001) and bone (105 of 107 [98%] for reader 1 and 102 of 107 [95%] for reader 2 vs 106 of 107 [99%] for reader 3 and 93 of 107 [87

  2. Robotic 3D scanner as an alternative to standard modalities of medical imaging.

    PubMed

    Chromy, Adam; Zalud, Ludek

    2014-01-01

    There are special medical cases, where standard medical imaging modalities are able to offer sufficient results, but not in the optimal way. It means, that desired results are produced with unnecessarily high expenses, with redundant informations or with needless demands on patient. This paper deals with one special case, where information useful for examination is the body surface only, inner sight into the body is needless. New specialized medical imaging device is developed for this situation. In the Introduction section, analysis of presently used medical imaging modalities is presented, which declares, that no available imaging device is best fitting for mentioned purposes. In the next section, development of the new specialized medical imaging device is presented, and its principles and functions are described. Then, the parameters of new device are compared with present ones. It brings significant advantages comparing to present imaging systems.

  3. Imaging Modalities Relevant to Intracranial Pressure Assessment in Astronauts

    NASA Technical Reports Server (NTRS)

    Sargsyan, Ashot E.; Kramer, Larry A.; Hamilton, Douglas R.; Fogarty, Jennifer; Polk, J. D.

    2011-01-01

    Learning Objectives of this slide presentation are: 1: To review the morphological changes in orbit structures caused by elevated Intracranial Pressure (ICP), and their imaging representation. 2: To learn about the similarities and differences between MRI and sonographic imaging of the eye and orbit. 3: To learn about the role of MRI and sonography in the noninvasive assessment of intracranial pressure in aerospace medicine, and the added benefits from their combined interpretation.

  4. SU-C-9A-06: The Impact of CT Image Used for Attenuation Correction in 4D-PET

    SciTech Connect

    Cui, Y; Bowsher, J; Yan, S; Cai, J; Das, S; Yin, F

    2014-06-01

    Purpose: To evaluate the appropriateness of using 3D non-gated CT image for attenuation correction (AC) in a 4D-PET (gated PET) imaging protocol used in radiotherapy treatment planning simulation. Methods: The 4D-PET imaging protocol in a Siemens PET/CT simulator (Biograph mCT, Siemens Medical Solutions, Hoffman Estates, IL) was evaluated. CIRS Dynamic Thorax Phantom (CIRS Inc., Norfolk, VA) with a moving glass sphere (8 mL) in the middle of its thorax portion was used in the experiments. The glass was filled with {sup 18}F-FDG and was in a longitudinal motion derived from a real patient breathing pattern. Varian RPM system (Varian Medical Systems, Palo Alto, CA) was used for respiratory gating. Both phase-gating and amplitude-gating methods were tested. The clinical imaging protocol was modified to use three different CT images for AC in 4D-PET reconstruction: first is to use a single-phase CT image to mimic actual clinical protocol (single-CT-PET); second is to use the average intensity projection CT (AveIP-CT) derived from 4D-CT scanning (AveIP-CT-PET); third is to use 4D-CT image to do the phase-matched AC (phase-matching- PET). Maximum SUV (SUVmax) and volume of the moving target (glass sphere) with threshold of 40% SUVmax were calculated for comparison between 4D-PET images derived with different AC methods. Results: The SUVmax varied 7.3%±6.9% over the breathing cycle in single-CT-PET, compared to 2.5%±2.8% in AveIP-CT-PET and 1.3%±1.2% in phasematching PET. The SUVmax in single-CT-PET differed by up to 15% from those in phase-matching-PET. The target volumes measured from single- CT-PET images also presented variations up to 10% among different phases of 4D PET in both phase-gating and amplitude-gating experiments. Conclusion: Attenuation correction using non-gated CT in 4D-PET imaging is not optimal process for quantitative analysis. Clinical 4D-PET imaging protocols should consider phase-matched 4D-CT image if available to achieve better accuracy.

  5. PET-MRI: a review of challenges and solutions in the development of integrated multimodality imaging

    NASA Astrophysics Data System (ADS)

    Vandenberghe, Stefaan; Marsden, Paul K.

    2015-02-01

    The integration of positron emission tomography (PET) and magnetic resonance imaging (MRI) has been an ongoing research topic for the last 20 years. This paper gives an overview of the different developments and the technical problems associated with combining PET and MRI in one system. After explaining the different detector concepts for integrating PET-MRI and minimising interference the limitations and advantages of different solutions for the detector and system are described for preclinical and clinical imaging systems. The different integrated PET-MRI systems are described in detail. Besides detector concepts and system integration the challenges and proposed solutions for attenuation correction and the potential for motion correction and resolution recovery are also discussed in this topical review.

  6. PET/MRI – Technical Review

    PubMed Central

    Muzic, Raymond F.; DiFilippo, Frank P.

    2015-01-01

    PET/MR is a hybrid imaging technology with the potential to combine the molecular and functional information of PET with the soft-tissue contrast of MR. Herein we review the technical features and challenges of putting these different technologies together. We emphasize the conceptual to make the material accessible to a wide audience. We begin by reviewing PET/CT, a more mature multi-modality imaging technology, to provide a basis for comparison to the history of PET/MR development. We discuss the motivation and challenges of PET/MR and different approaches that have been used to meet the challenges. We conclude with a speculation about the future of this exciting imaging method. PMID:25497909

  7. Multiphoton microscopy as a diagnostic imaging modality for lung cancer

    NASA Astrophysics Data System (ADS)

    Pavlova, Ina; Hume, Kelly R.; Yazinski, Stephanie A.; Peters, Rachel M.; Weiss, Robert S.; Webb, Watt W.

    2010-02-01

    Lung cancer is the leading killer among all cancers for both men and women in the US, and is associated with one of the lowest 5-year survival rates. Current diagnostic techniques, such as histopathological assessment of tissue obtained by computed tomography guided biopsies, have limited accuracy, especially for small lesions. Early diagnosis of lung cancer can be improved by introducing a real-time, optical guidance method based on the in vivo application of multiphoton microscopy (MPM). In particular, we hypothesize that MPM imaging of living lung tissue based on twophoton excited intrinsic fluorescence and second harmonic generation can provide sufficient morphologic and spectroscopic information to distinguish between normal and diseased lung tissue. Here, we used an experimental approach based on MPM with multichannel fluorescence detection for initial discovery that MPM spectral imaging could differentiate between normal and neoplastic lung in ex vivo samples from a murine model of lung cancer. Current results indicate that MPM imaging can directly distinguish normal and neoplastic lung tissues based on their distinct morphologies and fluorescence emission properties in non-processed lung tissue. Moreover, we found initial indication that MPM imaging differentiates between normal alveolar tissue, inflammatory foci, and lung neoplasms. Our long-term goal is to apply results from ex vivo lung specimens to aid in the development of multiphoton endoscopy for in vivo imaging of lung abnormalities in various animal models, and ultimately for the diagnosis of human lung cancer.

  8. Quality control for quantitative multicenter whole-body PET/MR studies: A NEMA image quality phantom study with three current PET/MR systems

    SciTech Connect

    Boellaard, Ronald; Rausch, Ivo; Beyer, Thomas; Delso, Gaspar; Yaqub, Maqsood; Quick, Harald H.; Sattler, Bernhard

    2015-10-15

    Purpose: Integrated positron emission tomography/magnetic resonance (PET/MR) systems derive the PET attenuation correction (AC) from dedicated MR sequences. While MR-AC performs reasonably well in clinical patient imaging, it may fail for phantom-based quality control (QC). The authors assess the applicability of different protocols for PET QC in multicenter PET/MR imaging. Methods: The National Electrical Manufacturers Association NU 2 2007 image quality phantom was imaged on three combined PET/MR systems: a Philips Ingenuity TF PET/MR, a Siemens Biograph mMR, and a GE SIGNA PET/MR (prototype) system. The phantom was filled according to the EANM FDG-PET/CT guideline 1.0 and scanned for 5 min over 1 bed. Two MR-AC imaging protocols were tested: standard clinical procedures and a dedicated protocol for phantom tests. Depending on the system, the dedicated phantom protocol employs a two-class (water and air) segmentation of the MR data or a CT-based template. Differences in attenuation- and SUV recovery coefficients (RC) are reported. PET/CT-based simulations were performed to simulate the various artifacts seen in the AC maps (μ-map) and their impact on the accuracy of phantom-based QC. Results: Clinical MR-AC protocols caused substantial errors and artifacts in the AC maps, resulting in underestimations of the reconstructed PET activity of up to 27%, depending on the PET/MR system. Using dedicated phantom MR-AC protocols, PET bias was reduced to −8%. Mean and max SUV RC met EARL multicenter PET performance specifications for most contrast objects, but only when using the dedicated phantom protocol. Simulations confirmed the bias in experimental data to be caused by incorrect AC maps resulting from the use of clinical MR-AC protocols. Conclusions: Phantom-based quality control of PET/MR systems in a multicenter, multivendor setting may be performed with sufficient accuracy, but only when dedicated phantom acquisition and processing protocols are used for

  9. [Optic disc drusen in children: Advantages of various imaging modalities].

    PubMed

    Naoum, S; Bouacha, I; Drumare, I; Marks, C; Defoort-Delemmes, S

    2016-04-01

    In children, optic disc drusen pose a diagnostic problem with papilledema when they are buried. The goal of our study is to retrospectively compare the results of examinations performed in 34 children with optic disc drusen. In children who underwent ultrasonography and autofluorescence imaging, the results were conclusive in both examinations in 44.7% of cases, and in neither of the two examinations in 27.6% of cases. Ultrasonography alone demonstrated superiority in diagnosing 27.6% of eyes, whereas autofluorescence imaging was inconclusive. Since diagnostic confusion with papilledema persisted in seven children, angiography was performed. B-mode ultrasonography constitutes a relevant examination in the diagnosis of buried optic disc drusen in children and shows superiority in our study compared to autofluorescence imaging.

  10. ImmunoPET Imaging of Insulin-Like Growth Factor 1 Receptor in a Subcutaneous Mouse Model of Pancreatic Cancer

    DTIC Science & Technology

    2016-06-30

    imaging, tumor- bearing mice were injected intravenously with ∼200 μCi of 89Zr-Df-1A2G11. PET scans were performed using an Inveon microPET/microCT rodent...Serial PET imaging was performed at 12, 24, 48, 72, and 120 h after 89Zr-Df-1A2G11 was injected into MIA PaCa-2, BxPC-3, and AsPC-1 tumor- bearing mice...displayed low expression. Figure 3. PET imaging of IGF-1R expression in three pancreatic cancer tumor- bearing mice. Maximum intensity projection images

  11. Netupitant PET imaging and ADME studies in humans

    PubMed Central

    Spinelli, Tulla; Calcagnile, Selma; Giuliano, Claudio; Rossi, Giorgia; Lanzarotti, Corinna; Mair, Stuart; Stevens, Lloyd; Nisbet, Ian

    2014-01-01

    Netupitant is a new, selective NK1 receptor antagonist under development for the prevention of chemotherapy-induced nausea and vomiting. Two studies were conducted to evaluate the brain receptor occupancy (RO) and disposition (ADME) of netupitant in humans. Positron emission tomography (PET) imaging with the NK1 receptor-binding–selective tracer [11C]-GR205171 was used to evaluate the brain penetration of different doses of netupitant (100, 300, and 450 mg) and to determine the NK1-RO duration. A NK1-RO of 90% or higher was achieved with all doses in the majority of the tested brain regions at Cmax, with a long duration of RO. The netupitant minimal plasma concentration predicted to achieve a NK1-RO of 90%, C90%, in the striatum was 225 ng/mL; after administration of netupitant 300 mg, concentrations exceeded the C90%. In the ADME study, a single nominal dose of [14C]-netupitant 300 mg was used to assess its disposition. Absorption was rapid and netupitant was extensively metabolized via Phase I and II hepatic metabolism. Elimination of >90% was predicted at day 29 and was principally via hepatic/biliary route (>85%) with a minor contribution of the renal route (<5%). In conclusion, these studies demonstrate that netupitant is a potent agent targeting NK1 receptors with long lasting RO. In addition, netupitant is extensively metabolized and is mainly eliminated through the hepatic/biliary route and to a lesser extent via the kidneys. PMID:24122871

  12. Automatic lung tumor segmentation on PET/CT images using fuzzy Markov random field model.

    PubMed

    Guo, Yu; Feng, Yuanming; Sun, Jian; Zhang, Ning; Lin, Wang; Sa, Yu; Wang, Ping

    2014-01-01

    The combination of positron emission tomography (PET) and CT images provides complementary functional and anatomical information of human tissues and it has been used for better tumor volume definition of lung cancer. This paper proposed a robust method for automatic lung tumor segmentation on PET/CT images. The new method is based on fuzzy Markov random field (MRF) model. The combination of PET and CT image information is achieved by using a proper joint posterior probability distribution of observed features in the fuzzy MRF model which performs better than the commonly used Gaussian joint distribution. In this study, the PET and CT simulation images of 7 non-small cell lung cancer (NSCLC) patients were used to evaluate the proposed method. Tumor segmentations with the proposed method and manual method by an experienced radiation oncologist on the fused images were performed, respectively. Segmentation results obtained with the two methods were similar and Dice's similarity coefficient (DSC) was 0.85 ± 0.013. It has been shown that effective and automatic segmentations can be achieved with this method for lung tumors which locate near other organs with similar intensities in PET and CT images, such as when the tumors extend into chest wall or mediastinum.

  13. Automatic Lung Tumor Segmentation on PET/CT Images Using Fuzzy Markov Random Field Model

    PubMed Central

    Guo, Yu; Feng, Yuanming; Sun, Jian; Lin, Wang; Sa, Yu; Wang, Ping

    2014-01-01

    The combination of positron emission tomography (PET) and CT images provides complementary functional and anatomical information of human tissues and it has been used for better tumor volume definition of lung cancer. This paper proposed a robust method for automatic lung tumor segmentation on PET/CT images. The new method is based on fuzzy Markov random field (MRF) model. The combination of PET and CT image information is achieved by using a proper joint posterior probability distribution of observed features in the fuzzy MRF model which performs better than the commonly used Gaussian joint distribution. In this study, the PET and CT simulation images of 7 non-small cell lung cancer (NSCLC) patients were used to evaluate the proposed method. Tumor segmentations with the proposed method and manual method by an experienced radiation oncologist on the fused images were performed, respectively. Segmentation results obtained with the two methods were similar and Dice's similarity coefficient (DSC) was 0.85 ± 0.013. It has been shown that effective and automatic segmentations can be achieved with this method for lung tumors which locate near other organs with similar intensities in PET and CT images, such as when the tumors extend into chest wall or mediastinum. PMID:24987451

  14. Construction of specific magnetic resonance imaging/optical dual-modality molecular probe used for imaging angiogenesis of gastric cancer.

    PubMed

    Yan, Xuejie; Song, Xiaoyan; Wang, Zhenbo

    2017-05-01

    The purpose of the study was to construct specific magnetic resonance imaging (MRI)/optical dual-modality molecular probe. Tumor-bearing animal models were established. MRI/optical dual-modality molecular probe was construed by coupling polyethylene glycol (PEG)-modified nano-Fe3O4 with specific targeted cyclopeptide GX1 and near-infrared fluorescent dyes Cy5.5. MRI/optical imaging effects of the probe were observed and the feasibility of in vivo double-modality imaging was discussed. It was found that, the double-modality probe was of high stability; tumor signal of the experimental group tended to be weak after injection of the probe, but rose to a level which was close to the previous level after 18 h (p > 0.05). We successively completed the construction of an ideal MRI/optical dual-modality molecular probe. MRI/optical dual-modality molecular probe which can selectively gather in gastric cancer is expected to be a novel probe used for diagnosing gastric cancer in the early stage.

  15. MO-FG-303-08: PET-Detectable Bimetallic (Zn@Au) Nanoparticles for Radiotherapy and Molecular Imaging Applications

    SciTech Connect

    Cho, J; Cho, S; Wang, M; Zubarev, E; Gonzalez-Lepera, C

    2015-06-15

    Purpose: A technical challenge in clinical translation of GNP-mediated radiotherapy is lack of in-vivo imaging tools for monitoring biodistribution of GNPs. While several modalities (x-ray fluorescence, photoacoustic, etc.) are investigated, we propose a potentially more effective technique based on PET imaging. We developed Zn@Au NPs whose Zn core acts as positron emitters when activated by protons, while the Au shell plays the original role for GNP-mediated radiosensitization. Methods: Spherical Zn NPs (∼7nm diameter) were synthesized and then coated with ∼7nm thick Au layer to make Zn@Au NPs (∼20nm diameter). A water slurry containing 29mg of Zn@Au NPs was deposited (<10µm thickness) on a thin cellulose target and subsequently baked to remove the water. The cellulose matrix was placed in an aluminum target holder and irradiated with 14.5MeV protons from a GE PETtrace cyclotron with 4µA for 5min. After irradiation the cellulose matrix with the NPs was placed in a dose calibrator to assay radioactivity. Gamma spectroscopy using a HPGe detector was conducted on a very small fraction (<1mg) of the irradiated NPs. Results: We measured 158µCi of activity 32min after end of bombardment (EOB) using 66Ga setting on the dose calibrator (contribution from the cellulose matrix is negligible) which decreased to 2µCi over a 24hrs period. A gamma spectrum started one hour after EOB on the small fraction and acquired for 700sec showed a strong peak at 511keV (∼40,000 counts) with several other peaks (highest peak <1200 counts) of smaller magnitude. Conclusion: Strong 511keV gamma emission from proton-activated Zn cores can potentially be utilized to image the biodistribution of Zn@Au NPs using a PET scanner. The developed Zn@Au NPs are expected to retain radiosensitizing capability similar to solid GNPs, while observable through PET imaging for human-sized objects. Moreover, bioconjugated PET-detectable GNPs would allow a new option to perform molecular imaging.

  16. Potential medical applications of the plasma focus in the radioisotope production for PET imaging

    NASA Astrophysics Data System (ADS)

    Roshan, M. V.; Razaghi, S.; Asghari, F.; Rawat, R. S.; Springham, S. V.; Lee, P.; Lee, S.; Tan, T. L.

    2014-06-01

    Devices other than the accelerators are desired to be investigated for generating high energy particles to induce nuclear reaction and positron emission tomography (PET) producing radioisotopes. The experimental data of plasma focus devices (PF) are studied and the activity scaling law for External Solid Target (EST) activation is established. Based on the scaling law and the techniques to enhance the radioisotopes production, the feasibility of generating the required activity for PET imaging is studied.

  17. Noninvasive diagnosis of cirrhosis: A review of different imaging modalities

    PubMed Central

    De Robertis, Riccardo; D’Onofrio, Mirko; Demozzi, Emanuele; Crosara, Stefano; Canestrini, Stefano; Pozzi Mucelli, Roberto

    2014-01-01

    Progressive hepatic fibrosis can lead to cirrhosis, so its early detection is fundamental. Staging fibrosis is also critical for prognosis and management. The gold standard for these aims is liver biopsy, but it has several drawbacks, as it is invasive, expensive, has poor acceptance, is prone to inter observer variability and sampling errors, has poor repeatability, and has a risk of complications and mortality. Therefore, non-invasive imaging tests have been developed. This review mainly focuses on the role of transient elastography, acoustic radiation force impulse imaging, and magnetic resonance-based methods for the noninvasive diagnosis of cirrhosis. PMID:24966594

  18. Whole body 18F-FDG PET/CT is superior to CT as first line diagnostic imaging in patients referred with serious non-specific symptoms or signs of cancer: a randomized prospective study of 200 patients.

    PubMed

    Lebech, Anne-Mette; Gaardsting, Anne; Loft, Annika; Graff, Jesper; Markova, Elena; Berthelsen, Anne Kiil; Madsen, Jan Lysgaard; Helms, Morten; Mathiesen, Lars R; David, Kim P; Kronborg, Gitte; Kjaer, Andreas

    2017-01-12

    A fast-track pathway has been established in Denmark to investigate patients with serious non-specific symptoms and signs of cancer (NSSC), which are not eligible to enter an organ-specific cancer program. The prevalence of cancer in this cohort is approximately 20%. The optimal screening strategy in patients with NSSC remains unknown. The aim was to investigate if (18)F-FDG-positron emission tomography/computed tomography (PET/CT) was superior to CT as initial imaging modality in patients with NSSC. In a randomized prospective trial the imaging modalities were compared with regard to diagnostic performance.

  19. Diffusion-weighted and PET/MR Imaging after Radiation Therapy for Malignant Head and Neck Tumors.

    PubMed

    Varoquaux, Arthur; Rager, Olivier; Dulguerov, Pavel; Burkhardt, Karim; Ailianou, Angeliki; Becker, Minerva

    2015-01-01

    Interpreting imaging studies of the irradiated neck constitutes a challenge because of radiation therapy-induced tissue alterations, the variable appearances of recurrent tumors, and functional and metabolic phenomena that mimic disease. Therefore, morphologic magnetic resonance (MR) imaging, diffusion-weighted (DW) imaging, positron emission tomography with computed tomography (PET/CT), and software fusion of PET and MR imaging data sets are increasingly used to facilitate diagnosis in clinical practice. Because MR imaging and PET often yield complementary information, PET/MR imaging holds promise to facilitate differentiation of tumor recurrence from radiation therapy-induced changes and complications. This review focuses on clinical applications of DW and PET/MR imaging in the irradiated neck and discusses the added value of multiparametric imaging to solve diagnostic dilemmas. Radiologists should understand key features of radiation therapy-induced tissue alterations and potential complications seen at DW and PET/MR imaging, including edema, fibrosis, scar tissue, soft-tissue necrosis, bone and cartilage necrosis, cranial nerve palsy, and radiation therapy-induced arteriosclerosis, brain necrosis, and thyroid disorders. DW and PET/MR imaging also play a complementary role in detection of residual and recurrent disease. Interpretation pitfalls due to technical, functional, and metabolic phenomena should be recognized and avoided. Familiarity with DW and PET/MR imaging features of expected findings, potential complications, and treatment failure after radiation therapy increases diagnostic confidence when interpreting images of the irradiated neck. Online supplemental material is available for this article.

  20. Pulmonary nodule detection in PET/CT images: improved approach using combined nodule detection and hybrid FP reduction

    NASA Astrophysics Data System (ADS)

    Teramoto, Atsushi; Fujita, Hiroshi; Tomita, Yoya; Takahashi, Katsuaki; Yamamuro, Osamu; Tamaki, Tsuneo

    2012-03-01

    In this study, an automated scheme for detecting pulmonary nodules in PET/CT images has been proposed using combined detection and hybrid false-positive (FP) reduction techniques. The initial nodule candidates were detected separately from CT and PET images. FPs were then eliminated in the initial candidates by using support vector machine with characteristic values obtained from CT and PET images. In the experiment, we evaluated proposed method using 105 cases of PET/CT images that were obtained in the cancer-screening program. We evaluated true positive fraction (TPF) and FP / case. As a result, TPFs of CT and PET detections were 0.76 and 0.44, respectively. However, by integrating the both results, TPF was reached to 0.82 with 5.14 FPs/case. These results indicate that our method may be of practical use for the detection of pulmonary nodules using PET/CT images.

  1. Role of MR Imaging and FDG PET/CT in Selection and Follow-up of Patients Treated with Pelvic Exenteration for Gynecologic Malignancies

    PubMed Central

    Nougaret, Stephanie; Miccò, Maura; Scelzo, Chiara; Vargas, Hebert A.; Sosa, Ramon E.; Sutton, Elizabeth J.; Chi, Dennis S.; Hricak, Hedvig; Sala, Evis

    2015-01-01

    Pelvic exenteration (PE) is a radical surgical procedure used for the past 6 decades to treat locally advanced malignant diseases confined to the pelvis, particularly persistent or recurrent gynecologic cancers in the irradiated pelvis. The traditional surgical technique known as total PE consists of resection of all pelvic viscera followed by reconstruction. Depending on the tumor extent, the procedure can be tailored to remove only anterior or posterior structures, including the bladder (anterior exenteration) or rectum (posterior exenteration). Conversely, more extended pelvic resection can be performed if the pelvic sidewall is invaded by cancer. Preoperative imaging evaluation with magnetic resonance (MR) imaging and fluorine 18 fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT) is central to establishing tumor resectability and therefore patient eligibility for the procedure. These imaging modalities complement each other in diagnosis of tumor recurrence and differentiation of persistent disease from posttreatment changes. MR imaging can accurately demonstrate local tumor extent and show adjacent organ invasion. FDG PET/CT is useful in excluding nodal and distant metastases. In addition, FDG PET/CT metrics may serve as predictive biomarkers for overall and disease-free survival. This pictorial review describes different types of exenterative surgical procedures and illustrates the central role of imaging in accurate patient selection, treatment planning, and postsurgical surveillance. ©RSNA, 2015 PMID:26172364

  2. Dedicated mobile high resolution prostate PET imager with an insertable transrectal probe

    DOEpatents

    Majewski, Stanislaw; Proffitt, James

    2010-12-28

    A dedicated mobile PET imaging system to image the prostate and surrounding organs. The imaging system includes an outside high resolution PET imager placed close to the patient's torso and an insertable and compact transrectal probe that is placed in close proximity to the prostate and operates in conjunction with the outside imager. The two detector systems are spatially co-registered to each other. The outside imager is mounted on an open rotating gantry to provide torso-wide 3D images of the prostate and surrounding tissue and organs. The insertable probe provides closer imaging, high sensitivity, and very high resolution predominately 2D view of the prostate and immediate surroundings. The probe is operated in conjunction with the outside imager and a fast data acquisition system to provide very high resolution reconstruction of the prostate and surrounding tissue and organs.

  3. [Image-guided radiotherapy: rational, modalities and results].

    PubMed

    de Crevoisier, R; Louvel, G; Cazoulat, G; Leseur, J; Lafond, C; Lahbabi, K; Chira, C; Lagrange, J-L

    2009-01-01

    The objective of Image-Guided Radiotherapy (IGRT) is to take in account the inter- or/and intrafraction anatomic variations (organ motion and deformations) in order to improve treatment accuracy. The IGRT should therefore translate in a clinical benefit the recent advances in both tumor definition thanks to functional imaging, and dose distribution thanks to intensity modulated radiotherapy. The IGRT enables direct or indirect tumor visualization during radiation delivery. If the tumor position does not correspond with the theoretical location of target derived from planning system, the table is moved. In case of important uncertainties related to target deformation, a new planning can be discussed. IGRT is realized by different types of devices which can vary in principle and as well as in their implementation: from LINAC-integrated-kV (or MV)-Cone Beam CTs to helicoidal tomotherapy, Cyberknife and Novalis low-energy stereoscopic imaging system. These techniques led to a more rational choice of Planning Target Volume. Being recently introduced in practice, the clinical results of this technique are still limited. Nevertheless, until so far, IGRT has showed promising results with reports of minimal acute toxicity. This review describes IGRT for various tumor localizations. The dose delivered by on board imaging should be taken in account. A strong quality control is required for safety and proper prospective evaluation of the clinical benefit of IGRT.

  4. Simultaneous dual modality optical and MR imaging of mouse dorsal skin-fold window chamber

    NASA Astrophysics Data System (ADS)

    Salek, Mir Farrokh; Pagel, Mark D.; Gmitro, Arthur F.

    2011-02-01

    Optical imaging and MRI have both been used extensively to study tumor microenvironment. The two imaging modalities are complementary and can be used to cross-validate one another for specific measurements. We have developed a modular platform that is capable of doing optical microscopy inside an MRI instrument. To do this, an optical relay system transfers the image to outside of the MR bore to a commercial grade CCD camera. This enables simultaneous optical and MR imaging of the same tissue and thus creates the ideal situation for comparative or complementary studies using both modalities. Initial experiments have been done using GFP labeled prostate cancer cells implanted in mouse dorsal skin fold window chamber. Vascular hemodynamics and vascular permeability were studied using our imaging system. Towards this goal, we developed a dual MR-Optical contrast agent by labeling BSA with both Gd-DTPA and Alexa Fluor. Overall system design and results of these preliminary vascular studies are presented.

  5. Three-dimensional Intraoperative Imaging Modalities in Orthopaedic Surgery: A Narrative Review.

    PubMed

    Qureshi, Sheeraz; Lu, Young; McAnany, Steven; Baird, Evan

    2014-12-01

    Intraoperative imaging and navigation systems have revolutionized orthopaedic surgery for the spine, joints, and orthopaedic trauma. Imaging modalities such as the isocentric C-arm, O-arm imaging, and intraoperative MRI or navigation systems allow the visualization of surgical instruments and implants relative to a three-dimensional CT image or MRI. Studies show that these technologies lower the rates of implant misplacement and inadequate fracture reduction, thereby improving surgical outcomes and reducing reoperation rates. An additional benefit is reduced radiation exposure compared with that for conventional fluoroscopy. Concerns surrounding adoption of these technologies include cost and increased operating times, but improvements in design and protocol may improve the integration of these imaging modalities into the operating room.

  6. Synergistic role of simultaneous PET/MRI-MRS in soft tissue sarcoma metabolism imaging.

    PubMed

    Zhang, Xiaomeng; Chen, Yen-Lin E; Lim, Ruth; Huang, Chuan; Chebib, Ivan A; El Fakhri, Georges

    2016-04-01

    The primary objective of this study was to develop and validate simultaneous PET/MRI-MRS as a novel biological image-guided approach to neoadjuvant radiotherapy (RT) and/or chemoradiation (chemoRT) in soft tissue sarcomas (STS). A patient with sarcoma of the right thigh underwent PET/MRI scan before and after neoadjuvant (preoperative) radiotherapy. The magnetic resonance imaging (MRI) and 2-deoxy-2-[fluorine-18]-fluoro-D-glucose-Positron Emission Tomography ((18)F-FDG-PET) scans were performed simultaneously. In the post-radiation scan, magnetic resonance spectroscopy (MRS) was subsequently acquired with volume of interest positioned in a residual hyper-metabolic region detected by PET. Post-radiation PET/MRI showed a residual T2-hyperintense mass with significantly reduced (18)F-FDG-uptake, compatible with near complete response to radiotherapy. However, a small region of residual high (18)F-FDG uptake was detected at the tumor margin. MRS of this region had similar metabolite profile as normal tissue, and was thus considered false positive on PET scan. Pathology results were obtained after surgery for confirmation of imaging findings.

  7. PET guidance in prostate cancer radiotherapy: Quantitative imaging to predict response and guide treatment.

    PubMed

    Cattaneo, G M; Bettinardi, V; Mapelli, P; Picchio, M

    2016-03-01

    Positron emission tomography (PET) allows a monitoring and recording of the spatial and temporal distribution of molecular/cellular processes for diagnostic and therapeutic applications. The aim of this review is to describe the current applications and to explore the role of PET in prostate cancer management, mainly in the radiation therapy (RT) scenario. The state-of-the art of PET for prostate cancer will be presented together with the impact of new specific PET tracers and technological developments aiming at obtaining better imaging quality, increased tumor detectability and more accurate volume delineation. An increased number of studies have been focusing on PET quantification methods as predictive biomarkers capable of guiding individualized treatment and improving patient outcome; the sophisticated advanced intensity modulated and imaged guided radiation therapy techniques (IMRT/IGRT) are capable of boosting more radioresistant tumor (sub)volumes. The use of advanced feature analyses of PET images is an approach that holds great promise with regard to several oncological diseases, but needs further validation in managing prostate diseases.

  8. Relative role of motion and PSF compensation in whole-body oncologic PET-MR imaging

    SciTech Connect

    Petibon, Yoann; Syrkina, Aleksandra; Huang, Chuan; Ouyang, Jinsong; Li, Quanzheng; El Fakhri, Georges; Reese, Timothy G.; Chen, Yen-Lin

    2014-04-15

    Purpose: Respiratory motion and partial-volume effects are the two main sources of image degradation in whole-body PET imaging. Simultaneous PET-MR allows measurement of respiratory motion using MRI while collecting PET events. Improved PET images may be obtained by modeling respiratory motion and point spread function (PSF) within the PET iterative reconstruction process. In this study, the authors assessed the relative impact of PSF modeling and MR-based respiratory motion correction in phantoms and patient studies using a whole-body PET-MR scanner. Methods: An asymmetric exponential PSF model accounting for radially varying and axial detector blurring effects was obtained from point source acquisitions performed in the PET-MR scanner. A dedicated MRI acquisition protocol using single-slice steady state free-precession MR acquisitions interleaved with pencil-beam navigator echoes was developed to track respiratory motion during PET-MR studies. An iterative ordinary Poisson fully 3D OSEM PET reconstruction algorithm modeling all the physical effects of the acquisition (attenuation, scatters, random events, detectors efficiencies, PSF), as well as MR-based nonrigid respiratory deformations of tissues (in both emission and attenuation maps) was developed. Phantom and{sup 18}F-FDG PET-MR patient studies were performed to evaluate the proposed quantitative PET-MR methods. Results: The phantom experiment results showed that PSF modeling significantly improved contrast recovery while limiting noise propagation in the reconstruction process. In patients with soft-tissue static lesions, PSF modeling improved lesion contrast by 19.7%–109%, enhancing the detectability and assessment of small tumor foci. In a patient study with small moving hepatic lesions, the proposed reconstruction technique improved lesion contrast by 54.4%–98.1% and reduced apparent lesion size by 21.8%–34.2%. Improvements were particularly important for the smallest lesion undergoing large motion

  9. Optimization of super-resolution processing using incomplete image sets in PET imaging.

    PubMed

    Chang, Guoping; Pan, Tinsu; Clark, John W; Mawlawi, Osama R

    2008-12-01

    Super-resolution (SR) techniques are used in PET imaging to generate a high-resolution image by combining multiple low-resolution images that have been acquired from different points of view (POVs). The number of low-resolution images used defines the processing time and memory storage necessary to generate the SR image. In this paper, the authors propose two optimized SR implementations (ISR-1 and ISR-2) that require only a subset of the low-resolution images (two sides and diagonal of the image matrix, respectively), thereby reducing the overall processing time and memory storage. In an N x N matrix of low-resolution images, ISR-1 would be generated using images from the two sides of the N x N matrix, while ISR-2 would be generated from images across the diagonal of the image matrix. The objective of this paper is to investigate whether the two proposed SR methods can achieve similar performance in contrast and signal-to-noise ratio (SNR) as the SR image generated from a complete set of low-resolution images (CSR) using simulation and experimental studies. A simulation, a point source, and a NEMA/IEC phantom study were conducted for this investigation. In each study, 4 (2 x 2) or 16 (4 x 4) low-resolution images were reconstructed from the same acquired data set while shifting the reconstruction grid to generate images from different POVs. SR processing was then applied in each study to combine all as well as two different subsets of the low-resolution images to generate the CSR, ISR-1, and ISR-2 images, respectively. For reference purpose, a native reconstruction (NR) image using the same matrix size as the three SR images was also generated. The resultant images (CSR, ISR-1, ISR-2, and NR) were then analyzed using visual inspection, line profiles, SNR plots, and background noise spectra. The simulation study showed that the contrast and the SNR difference between the two ISR images and the CSR image were on average 0.4% and 0.3%, respectively. Line profiles of

  10. FULLY CONVOLUTIONAL NETWORKS FOR MULTI-MODALITY ISOINTENSE INFANT BRAIN IMAGE SEGMENTATION.

    PubMed

    Nie, Dong; Wang, Li; Gao, Yaozong; Shen, Dinggang

    The segmentation of infant brain tissue images into white matter (WM), gray matter (GM), and cerebrospinal fluid (CSF) plays an important role in studying early brain development. In the isointense phase (approximately 6-8 months of age), WM and GM exhibit similar levels of intensity in both T1 and T2 MR images, resulting in extremely low tissue contrast and thus making the tissue segmentation very challenging. The existing methods for tissue segmentation in this isointense phase usually employ patch-based sparse labeling on single T1, T2 or fractional anisotropy (FA) modality or their simply-stacked combinations without fully exploring the multi-modality information. To address the challenge, in this paper, we propose to use fully convolutional networks (FCNs) for the segmentation of isointense phase brain MR images. Instead of simply stacking the three modalities, we train one network for each modality image, and then fuse their high-layer features together for final segmentation. Specifically, we conduct a convolution-pooling stream for multimodality information from T1, T2, and FA images separately, and then combine them in high-layer for finally generating the segmentation maps as the outputs. We compared the performance of our approach with that of the commonly used segmentation methods on a set of manually segmented isointense phase brain images. Results showed that our proposed model significantly outperformed previous methods in terms of accuracy. In addition, our results also indicated a better way of integrating multi-modality images, which leads to performance improvement.

  11. FULLY CONVOLUTIONAL NETWORKS FOR MULTI-MODALITY ISOINTENSE INFANT BRAIN IMAGE SEGMENTATION

    PubMed Central

    Nie, Dong; Wang, Li; Gao, Yaozong; Shen, Dinggang

    2016-01-01

    The segmentation of infant brain tissue images into white matter (WM), gray matter (GM), and cerebrospinal fluid (CSF) plays an important role in studying early brain development. In the isointense phase (approximately 6–8 months of age), WM and GM exhibit similar levels of intensity in both T1 and T2 MR images, resulting in extremely low tissue contrast and thus making the tissue segmentation very challenging. The existing methods for tissue segmentation in this isointense phase usually employ patch-based sparse labeling on single T1, T2 or fractional anisotropy (FA) modality or their simply-stacked combinations without fully exploring the multi-modality information. To address the challenge, in this paper, we propose to use fully convolutional networks (FCNs) for the segmentation of isointense phase brain MR images. Instead of simply stacking the three modalities, we train one network for each modality image, and then fuse their high-layer features together for final segmentation. Specifically, we conduct a convolution-pooling stream for multimodality information from T1, T2, and FA images separately, and then combine them in high-layer for finally generating the segmentation maps as the outputs. We compared the performance of our approach with that of the commonly used segmentation methods on a set of manually segmented isointense phase brain images. Results showed that our proposed model significantly outperformed previous methods in terms of accuracy. In addition, our results also indicated a better way of integrating multi-modality images, which leads to performance improvement. PMID:27668065

  12. Multi-modal Color Medical Image Fusion Using Quaternion Discrete Fourier Transform

    NASA Astrophysics Data System (ADS)

    Nawaz, Qamar; Xiao, Bin; Hamid, Isma; Jiao, Du

    2016-12-01

    Multimodal image fusion is a process of combining multiple images, generated by identical or diverse imaging modalities, to get precise inside information about the same body organ. In recent years, various multimodal image fusion algorithms have been proposed to fuse medical image. However, most of them focus on fusing grayscale images. This paper proposes a novel algorithm for the fusion of multimodal color medical images. The proposed algorithm divides source images into blocks, converts each RGB block into quaternion representation and transforms them from special domain to frequency domain by applying quaternion discrete Fourier transform. The fused coefficients are obtained by calculating and comparing contrast values of corresponding coefficients in transformed blocks. The resultant fused image is reconstructed by merging all the blocks after applying inverse quaternion discrete Fourier transform on each block. Experimental evaluation demonstrates that the proposed algorithm qualitatively outperforms many existing state-of-the-art multimodal image fusion algorithms.

  13. Structured light 3D tracking system for measuring motions in PET brain imaging

    NASA Astrophysics Data System (ADS)

    Olesen, Oline V.; Jørgensen, Morten R.; Paulsen, Rasmus R.; Højgaard, Liselotte; Roed, Bjarne; Larsen, Rasmus

    2010-02-01

    Patient motion during scanning deteriorates image quality, especially for high resolution PET scanners. A new proposal for a 3D head tracking system for motion correction in high resolution PET brain imaging is set up and demonstrated. A prototype tracking system based on structured light with a DLP projector and a CCD camera is set up on a model of the High Resolution Research Tomograph (HRRT). Methods to reconstruct 3D point clouds of simple surfaces based on phase-shifting interferometry (PSI) are demonstrated. The projector and camera are calibrated using a simple stereo vision procedure where the projector is treated as a camera. Additionally, the surface reconstructions are corrected for the non-linear projector output prior to image capture. The results are convincing and a first step toward a fully automated tracking system for measuring head motions in PET imaging.

  14. Variability of Image Features Computed from Conventional and Respiratory-Gated PET/CT Images of Lung Cancer

    PubMed Central

    Oliver, Jasmine A.; Budzevich, Mikalai; Zhang, Geoffrey G.; Dilling, Thomas J.; Latifi, Kujtim; Moros, Eduardo G.

    2015-01-01

    Radiomics is being explored for potential applications in radiation therapy. How various imaging protocols affect quantitative image features is currently a highly active area of research. To assess the variability of image features derived from conventional [three-dimensional (3D)] and respiratory-gated (RG) positron emission tomography (PET)/computed tomography (CT) images of lung cancer patients, image features were computed from 23 lung cancer patients. Both protocols for each patient were acquired during the same imaging session. PET tumor volumes were segmented using an adaptive technique which accounted for background. CT tumor volumes were delineated with a commercial segmentation tool. Using RG PET images, the tumor center of mass motion, length, and rotation were calculated. Fifty-six image features were extracted from all images consisting of shape descriptors, first-order features, and second-order texture features. Overall, 26.6% and 26.2% of total features demonstrated less than 5% difference between 3D and RG protocols for CT and PET, respectively. Between 10 RG phases in PET, 53.4% of features demonstrated percent differences less than 5%. The features with least variability for PET were sphericity, spherical disproportion, entropy (first and second order), sum entropy, information measure of correlation 2, Short Run Emphasis (SRE), Long Run Emphasis (LRE), and Run Percentage (RPC); and those for CT were minimum intensity, mean intensity, Root Mean Square (RMS), Short Run Emphasis (SRE), and RPC. Quantitative analysis using a 3D acquisition versus RG acquisition (to reduce the effects of motion) provided notably different image feature values. This study suggests that the variability between 3D and RG features is mainly due to the impact of respiratory motion. PMID:26692535

  15. Telepathology and imaging spectroscopy as a new modality in histopathology.

    PubMed

    Vari, S G; Müller, G; Lerner, J M; Naber, R D

    1999-01-01

    Telemedicine started in the late 1950's by transmitting data on patients' pulse and heart rates. In the 1980's it expanded to radiology and orthopedics. The technology is now expanding to other specialties that can digitally gather patient data. Telepathology comprises the transmission of microscopic images via telecommunication network. Image compression and multiplexing technologies enabled high-resolution telepathology as well as real-time video consultations over international telephone lines. Organ transplantation has become a viable treatment and offers new life to an increasing number of patients suffering from chronic end stage diseases and from irreversible organ failure. Rejection is still a major problem in kidney, liver, and heart transplantation. To gain further insight into the complex interactions within the components of the immune system, it has become increasingly necessary to develop rapid and simple methods to monitor the status of the immune system in patients. Clinical signs suggest organ rejection and abnormal laboratory test results, but only histological signs on biopsy specimens are adequately specific. The financial cost of organ transplant makes it imperative to develop tools for the early identification and treatment of organ rejection. An increasingly sensitive and accurate way of localizing key structures and abnormalities is through spectroscopy of either H&E stained samples or with a fluorescent tag (fluorophore) or by relying on natural fluorescence. The system is based on a unique Prism and Mirror Imaging Spectroscopy System ("PARISS), spectrometer originally designed and implemented for remote Earth monitoring from space and aircraft and astronomical imaging spectroscopy. Compact and lightweight both the mirror and prism are presently constructed in inexpensive glass but can also be injection molded in plastic. Any number of vendors anywhere in the world can produce all parts of the assembly. This greatly enhances the chances of

  16. [Metabolically active volumes automatic delineation methodologies in PET imaging: review and perspectives].

    PubMed

    Hatt, M; Boussion, N; Cheze-Le Rest, C; Visvikis, D; Pradier, O

    2012-02-01

    PET imaging is now considered a gold standard tool in clinical oncology, especially for diagnosis purposes. More recent applications such as therapy follow-up or tumor targeting in radiotherapy require a fast, accurate and robust metabolically active tumor volumes delineation on emission images, which cannot be obtained through manual contouring. This clinical need has sprung a large number of methodological developments regarding automatic methods to define tumor volumes on PET images. This paper reviews most of the methodologies that have been recently proposed and discusses their framework and methodological and/or clinical validation. Perspectives regarding the future work to be done are also suggested.

  17. Urolithoscintigraphy: preliminary report of a new imaging modality for urolithiasis.

    PubMed

    Wolf, J S; Irby, P B; Shields, A; Yuen-Green, M S; Hattner, R S; Stoller, M L

    1994-04-01

    We investigated the use of bisphosphonates, analogs of pyrophosphate that bind to mineralized tissue, to image renal calculi in vivo. Twenty stone-bearing kidneys in 15 patients without urinary obstruction were studied. 99mTechnetium-methylene diphosphonate was injected intravenously followed by 20 mg of furosemide 4 hours later, and images were obtained by gamma counter for 30 minutes. Areas of increased uptake corresponded with the sites of calculi, and even small or radiolucent calculi were easily seen. Counts in the region of each kidney, the L4 vertebral body, and a background area were combined to calculate a scintigram index (SI) for each kidney. The mean SI of the stone-bearing kidneys was 4.8 +/- 3.5 v 1.3 +/- 0.4 for the normal kidneys. There was correlation of the SI with stone composition and size but not with radiographic density. After correction for size, the SI of stone-bearing kidneys remained significantly higher than the SI of normal kidneys, but the differences between calculi of different compositions were diminished. Nonetheless, high SI values were associated with soft types of calculi and low values with hard types. Future investigations will reveal if this association is constant and if there is any relation between bisphosphonate uptake and response to lithotripsy. The sensit