Yang, Yanqin; Chu, Guohai; Zhou, Guojun; Jiang, Jian; Yuan, Kailong; Pan, Yuanjiang; Song, Zhiyu; Li, Zuguang; Xia, Qian; Lu, Xinbo; Xiao, Weiqiang
2016-03-01
An ultrasound-microwave synergistic extraction coupled to headspace solid-phase microextraction was first employed to determine the volatile components in tobacco samples. The method combined the advantages of ultrasound, microwave, and headspace solid-phase microextraction. The extraction, separation, and enrichment were performed in a single step, which could greatly simplify the operation and reduce the whole pretreatment time. In the developed method, several experimental parameters, such as fiber type, ultrasound power, and irradiation time, were optimized to improve sampling efficiency. Under the optimal conditions, there were 37, 36, 34, and 36 components identified in tobacco from Guizhou, Hunan, Yunnan, and Zimbabwe, respectively, including esters, heterocycles, alkanes, ketones, terpenoids, acids, phenols, and alcohols. The compound types were roughly the same while the contents were varied from different origins due to the disparity of their growing conditions, such as soil, water, and climate. In addition, the ultrasound-microwave synergistic extraction coupled to headspace solid-phase microextraction method was compared with the microwave-assisted extraction coupled to headspace solid-phase microextraction and headspace solid-phase microextraction methods. More types of volatile components were obtained by using the ultrasound-microwave synergistic extraction coupled to headspace solid-phase microextraction method, moreover, the contents were high. The results indicated that the ultrasound-microwave synergistic extraction coupled to headspace solid-phase microextraction technique was a simple, time-saving and highly efficient approach, which was especially suitable for analysis of the volatile components in tobacco. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
A rapid method for estimating polychlorinated biphenyl (PCB) concentrations in contaminated soils and sediments has been developed by coupling static subcritical water extraction with solid-phase microextraction (SPME). Soil, water, and internal standards are placed in a seale...
Furukawa, Makoto; Takagai, Yoshitaka
2016-10-04
Online solid-phase extraction (SPE) coupled with inductively coupled plasma mass spectrometry (ICPMS) is a useful tool in automatic sequential analysis. However, it cannot simultaneously quantify the analytical targets and their recovery percentages (R%) in one-shot samples. We propose a system that simultaneously acquires both data in a single sample injection. The main flowline of the online solid-phase extraction is divided into main and split flows. The split flow line (i.e., bypass line), which circumvents the SPE column, was placed on the main flow line. Under program-controlled switching of the automatic valve, the ICPMS sequentially measures the targets in a sample before and after column preconcentration and determines the target concentrations and the R% on the SPE column. This paper describes the system development and two demonstrations to exhibit the analytical significance, i.e., the ultratrace amounts of radioactive strontium ( 90 Sr) using commercial Sr-trap resin and multielement adsorbability on the SPE column. This system is applicable to other flow analyses and detectors in online solid phase extraction.
Yang, Yanqin; Pan, Yuanjiang; Zhou, Guojun; Chu, Guohai; Jiang, Jian; Yuan, Kailong; Xia, Qian; Cheng, Changhe
2016-11-01
A novel infrared-assisted extraction coupled to headspace solid-phase microextraction followed by gas chromatography with mass spectrometry method has been developed for the rapid determination of the volatile components in tobacco. The optimal extraction conditions for maximizing the extraction efficiency were as follows: 65 μm polydimethylsiloxane-divinylbenzene fiber, extraction time of 20 min, infrared power of 175 W, and distance between the infrared lamp and the headspace vial of 2 cm. Under the optimum conditions, 50 components were found to exist in all ten tobacco samples from different geographical origins. Compared with conventional water-bath heating and nonheating extraction methods, the extraction efficiency of infrared-assisted extraction was greatly improved. Furthermore, multivariate analysis including principal component analysis, hierarchical cluster analysis, and similarity analysis were performed to evaluate the chemical information of these samples and divided them into three classifications, including rich, moderate, and fresh flavors. The above-mentioned classification results were consistent with the sensory evaluation, which was pivotal and meaningful for tobacco discrimination. As a simple, fast, cost-effective, and highly efficient method, the infrared-assisted extraction coupled to headspace solid-phase microextraction technique is powerful and promising for distinguishing the geographical origins of the tobacco samples coupled to suitable chemometrics. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Continuous extraction of organic materials from water
Goldberg, M.C.; DeLong, L.; Kahn, L.
1971-01-01
A continuous liquid solvent extractor, designed to utilize organic solvents that are heavier than water, is described. The extractor is capable of handling input rates up to 2 liters per hour and has a 500-ml. extractant capacity. Extraction efficiency is dependent upon the p-value, the two solvent ratios, rate of flow of the aqueous phase, and rate of reflux of the organic phase. Extractors can be serially coupled to increase extraction efficiency and, when coupled with a lighter-than-water extractor, the system will allow the use of any immiscible solvent.
Ensafi, Ali A; Khoddami, Elaheh; Rezaei, Behzad
2013-01-01
In this paper, we describe a new combination method based on polytetrafluorethylene (PTFE) film-based liquid three-phase micro extraction coupled with differential pulse voltammetry (DPV) for the micro extraction and quantification of atorvastatin calcium (ATC) at the ultra-trace level. Different factors affecting the liquid-three phases micro extraction of atorvastatin calcium, including organic solvent, pH of the donor and acceptor phases, concentration of salt, extraction time, stirring rate and electrochemical factors, were investigated, and the optimal extraction conditions were established. The final stable signal was achieved after a 50 min extraction time, which was used for analytical applications. An enrichment factor of 21 was achieved, and the relative standard deviation (RSD) of the method was 4.5% (n = 4). Differential pulse voltammetry exhibited two wide linear dynamic ranges of 20.0-1000.0 pmol L(-1) and 0.001-11.0 µmol L(-1) of ATC. The detection limit was found to be 8.1 pmol L(-1) ATC. Finally, the proposed method was used as a new combination method for the determination of atorvastatin calcium in real samples, such as human urine and plasma.
An analytical method has been developed to determine the chloroethene series, tetrachloroethene (PCE), trichloroethene (TCE),cisdichloroethene (cis-DCE) andtransdichloroethene (trans-DCE) in environmental biotreatment studies using gas chromatography coupled with a solid phase mi...
Zhang, Yuchi; Liu, Chunming; Li, Jing; Qi, Yanjuan; Li, Yuchun; Li, Sainan
2015-09-01
A new method for the extraction of medicinal herbs termed ultrasonic-assisted dynamic extraction (UADE) was designed and evaluated. This technique was coupled with counter-current chromatography (CCC) and centrifugal partition chromatography (CPC) and then applied to the continuous extraction and online isolation of chemical constituents from Paeonia lactiflora Pall (white peony) roots. The mechanical parameters, including the pitch and diameter of the shaft, were optimized by means of mathematical modeling. Furthermore, the configuration and mechanism of online UADE coupled with CCC and CPC were elaborated. The stationary phases of the two-phase solvent systems from CCC and CPC were utilized as the UADE solution. The extraction solution was pumped into the sample loop and then introduced into the CCC column; the target compounds were eluted with the lower aqueous phase of the two-phase solvent system. During the CCC separation, the extraction solution was continuously fed in the sample loop by turning the ten-port valve; the extraction solution was then pumped into the CPC column and eluted by the mobile phase of the two-phase solvent system mentioned above. When the first cycle of the UADE/CCC/CPC was completed, the second cycle experiment could be carried out, and so on. Four target compounds (albiflorin, benzoylpaeoniflorin, paeoniflorin, and galloylpaeoniflorin) with purities above 94.96% were successfully extracted and isolated online using the two-phase solvent system comprising ethyl acetate-n-butanol-ethanol-water (1:3.5:2:4.5, v/v/v/v). Compared with conventional extraction methods, the instrumental setup of the present method offers the advantages of automation and systematic extraction and isolation of natural products. Crown Copyright © 2015. Published by Elsevier B.V. All rights reserved.
Sugaring-out extraction of acetoin from fermentation broth by coupling with fermentation.
Dai, Jian-Ying; Ma, Lin-Hui; Wang, Zhuang-Fei; Guan, Wen-Tian; Xiu, Zhi-Long
2017-03-01
Acetoin is a natural flavor and an important bio-based chemical which could be separated from fermentation broth by solvent extraction, salting-out extraction or recovered in the form of derivatives. In this work, a novel method named as sugaring-out extraction coupled with fermentation was tried in the acetoin production by Bacillus subtilis DL01. The effects of six solvents on bacterial growth and the distribution of acetoin and glucose in different solvent-glucose systems were explored. The operation parameters such as standing time, glucose concentration, and volume ratio of ethyl acetate to fermentation broth were determined. In a system composed of fermentation broth, glucose (100%, m/v) and two-fold volume of ethyl acetate, nearly 100% glucose was distributed into bottom phase, and 61.2% acetoin into top phase without coloring matters and organic acids. The top phase was treated by vacuum distillation to remove solvent and purify acetoin, while the bottom phase was used as carbon source to produce acetoin in the next batch of fermentation.
Inferring cardiac phase response curve in vivo
NASA Astrophysics Data System (ADS)
Pikovsky, Arkady; Kralemann, Bjoern; Fruehwirth, Matthias; Rosenblum, Michael; Kenner, Thomas; Schaefer, Jochen; Moser, Maximilian
2014-03-01
Characterizing properties of biological oscillators with phase response cirves (PRC) is one of main theoretical tools in neuroscience, cardio-respiratory physiology, and chronobiology. We present a technique that allows the extraction of the PRC from a non-invasive observation of a system consisting of two interacting oscillators, in this case heartbeat and respiration, in its natural environment and under free-running conditions. We use this method to obtain the phase coupling functions describing cardio-respiratory interactions and the phase response curve of 17 healthy humans. We show at which phase the cardiac beat is susceptible to respiratory drive and extract the respiratory-related component of heart rate variability. This non-invasive method of bivariate data analysis for the determination of phase response curves of coupled oscillators may find application in other biological and physical systems.
Review of online coupling of sample preparation techniques with liquid chromatography.
Pan, Jialiang; Zhang, Chengjiang; Zhang, Zhuomin; Li, Gongke
2014-03-07
Sample preparation is still considered as the bottleneck of the whole analytical procedure, and efforts has been conducted towards the automation, improvement of sensitivity and accuracy, and low comsuption of organic solvents. Development of online sample preparation techniques (SP) coupled with liquid chromatography (LC) is a promising way to achieve these goals, which has attracted great attention. This article reviews the recent advances on the online SP-LC techniques. Various online SP techniques have been described and summarized, including solid-phase-based extraction, liquid-phase-based extraction assisted with membrane, microwave assisted extraction, ultrasonic assisted extraction, accelerated solvent extraction and supercritical fluids extraction. Specially, the coupling approaches of online SP-LC systems and the corresponding interfaces have been discussed and reviewed in detail, such as online injector, autosampler combined with transport unit, desorption chamber and column switching. Typical applications of the online SP-LC techniques have been summarized. Then the problems and expected trends in this field are attempted to be discussed and proposed in order to encourage the further development of online SP-LC techniques. Copyright © 2014 Elsevier B.V. All rights reserved.
Phase coupling in the cardiorespiratory interaction.
Bahraminasab, A; Kenwright, D; Stefanovska, A; Ghasemi, F; McClintock, P V E
2008-01-01
Markovian analysis is applied to derive nonlinear stochastic equations for the reconstruction of heart rate and respiration rate variability data. A model of their 'phase' interactions is obtained for the first time, thereby gaining new insights into the strength and direction of the cardiorespiratory phase coupling. The reconstructed model can reproduce synchronisation phenomena between the cardiac and the respiratory systems, including switches in synchronisation ratio. The technique is equally applicable to the extraction of the multi-dimensional couplings between many interacting subsystems.
González-Fuenzalida, R. A.; Moliner-Martínez, Y.; Prima-Garcia, Helena; Ribera, Antonio; Campins-Falcó, P.; Zaragozá, Ramon J.
2014-01-01
The use of magnetic nanomaterials for analytical applications has increased in the recent years. In particular, magnetic nanomaterials have shown great potential as adsorbent phase in several extraction procedures due to the significant advantages over the conventional methods. In the present work, the influence of magnetic forces over the extraction efficiency of triazines using superparamagnetic silica nanoparticles (NPs) in magnetic in tube solid phase microextraction (Magnetic-IT-SPME) coupled to CapLC has been evaluated. Atrazine, terbutylazine and simazine has been selected as target analytes. The superparamagnetic silica nanomaterial (SiO2-Fe3O4) deposited onto the surface of a capillary column gave rise to a magnetic extraction phase for IT-SPME that provided a enhancemment of the extraction efficiency for triazines. This improvement is based on two phenomena, the superparamegnetic behavior of Fe3O4 NPs and the diamagnetic repulsions that take place in a microfluidic device such a capillary column. A systematic study of analytes adsorption and desorption was conducted as function of the magnetic field and the relationship with triazines magnetic susceptibility. The positive influence of magnetism on the extraction procedure was demonstrated. The analytical characteristics of the optimized procedure were established and the method was applied to the determination of the target analytes in water samples with satisfactory results. When coupling Magnetic-IT-SPME with CapLC, improved adsorption efficiencies (60%–63%) were achieved compared with conventional adsorption materials (0.8%–3%). PMID:28344221
Gadzała-Kopciuch, Renata; Cendrowski, Krzysztof; Cesarz, Anna; Kiełbasa, Paweł; Buszewski, Bogusław
2011-10-01
This study presents a selective method of isolation of zearalenone (ZON) and its metabolite, α-zearalenol (α-ZOL), in neoplastically changed human tissue by accelerated solvent and ultrasonic extractions using a mixture of acetonitrile/water (84/16% v/v) as the extraction solvent. Extraction effectiveness was determined through the selection of parameters (composition of the solvent mixture, temperature, pressure, number of cycles) with tissue contamination at the level of nanograms per gram. The produced acetonitrile/water extracts were purified, and analytes were enriched in columns packed with homemade molecularly imprinted polymers. Purified extracts were determined by liquid chromatography (LC) coupled with different detection systems (diode array detection--DAD and mass spectrometry--MS) involving the Ascentis RP-Amide as a stationary phase and gradient elution. The combination of UE-MISPE-LC (ultrasonic extraction--molecularly imprinted solid-phase extraction--liquid chromatography) produced high (R≈95-98%) and repeatable (RSD<3%) recovery values for ZON and α-ZOL. © The Author(s) 2011. This article is published with open access at Springerlink.com
Local phase method for designing and optimizing metasurface devices.
Hsu, Liyi; Dupré, Matthieu; Ndao, Abdoulaye; Yellowhair, Julius; Kanté, Boubacar
2017-10-16
Metasurfaces have attracted significant attention due to their novel designs for flat optics. However, the approach usually used to engineer metasurface devices assumes that neighboring elements are identical, by extracting the phase information from simulations with periodic boundaries, or that near-field coupling between particles is negligible, by extracting the phase from single particle simulations. This is not the case most of the time and the approach thus prevents the optimization of devices that operate away from their optimum. Here, we propose a versatile numerical method to obtain the phase of each element within the metasurface (meta-atoms) while accounting for near-field coupling. Quantifying the phase error of each element of the metasurfaces with the proposed local phase method paves the way to the design of highly efficient metasurface devices including, but not limited to, deflectors, high numerical aperture metasurface concentrators, lenses, cloaks, and modulators.
Sun, Hui; Lai, Jia-Ping; Fung, Ying Sing
2014-09-05
A novel method coupling molecular imprinting solid-phase extraction (MISPE) and micellar electrokinetic capillary chromatography (MEKC) was developed to enable the hourly determination of low level of ambient carbonyls, and study their partition between gaseous phase and particulate phase. With 2,4-dinitroaniline (DNAN) as dummy imprinting template, the unreacted 2,4-Dinitrophenylhydrazine (DNPH) in sampling solution could be removed effectively using MISPE, and an average recovery of 97±5.3% (n=5) for the carbonyl-DNPH derivatives was achieved. Owing to the high enrichment due to sample clean-up, and the improvement of MEKC separation efficiency, many low abundant carbonyls could be detected by hourly in the field study. Copyright © 2014 Elsevier B.V. All rights reserved.
Peña-Alvarez, Araceli; Díaz, Laura; Medina, Alejandra; Labastida, Carmen; Capella, Santiago; Vera, Luz Elena
2004-02-20
Steam distillation (SD) extraction-solid-phase microextraction coupled to GC-MS was developed for the determination of terpenes and Bligh-Dyer extraction-derivatization coupled with GC for the determination of fatty acids such as ethyl esters were used. It was found that the three different Agave species have the same profile of fatty acids; the quantity of these compounds is different in each Agave variety. On the other hand, different terpenes were identified in the three Agave plants studied: nine in A. salmiana, eight in A. angustifolia and 32 in A. tequilana Weber var. azul.
Jiao, Lijin; Tao, Yanduo; Wang, Weidong; Shao, Yun; Mei, Lijuan; Wang, Qilan; Dang, Jun
2017-10-01
An offline preparative two-dimensional reversed-phase liquid chromatography/hydrophilic interaction liquid chromatography coupled with hydrophilic interaction solid-phase extraction method was developed for the preparative isolation of flavonoid glycosides from a crude sample of Sphaerophysa salsula. First, the non-flavonoids were removed using an XAmide solid-phase extraction cartridge. Based on the separation results of three different chromatographic stationary phases, the first-dimensional preparation was performed on an XAqua C18 prep column, and 15 fractions were obtained from the 5.2 g target sample. Then, three representative fractions were selected for additional purification on an XAmide preparative column to further isolate the flavonoid glycosides. In all, eight flavonoid glycosides were isolated in purities over 97%. The results demonstrated that the two-dimensional liquid chromatography method used in this study was effective for the preparative separation of flavonoid glycosides from Sphaerophysa salsula. Additionally, this method showed great potential for the separation of flavonoid glycosides from other plant materials. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Loconto, Paul R; Isenga, David; O'Keefe, Michael; Knottnerus, Mark
2008-01-01
Polybrominated diphenyl ethers (PBDEs) are isolated and recovered with acceptable percent recoveries from human serum via liquid-liquid extraction and column chromatographic cleanup and fractionation with quantitation using capillary gas chromatography-mass spectrometry with electron capture negative ion and selected ion monitoring. PBDEs are found in unspiked serum. An alternative sample preparation approach is developed using sheep serum that utilizes a formic acid pre-treatment followed by reversed-phase solid-phase disk extraction and normal-phase solid-phase cleanup using acidified silica gel that yields>50% recoveries. When these percent recoveries are combined with a minimized phase ratio for human serum and very low instrument detection limits, method detection limits below 500 parts-per-trillion are realized.
USDA-ARS?s Scientific Manuscript database
Fusaric acid is a phytotoxin and mycotoxin occasionally found in maize contaminated with Fusarium fungi. A selective sample clean-up procedure was developed to detect fusaric acid in maize using molecularly imprinted solid phase extraction (MISPE) clean-up coupled with ion-pair liquid chromatography...
Isolation and characterization of antimicrobial food components.
Papetti, Adele
2012-04-01
Nowadays there is an evident growing interest in natural antimicrobial compounds isolated from food matrices. According to the type of matrix, different isolation and purification steps are needed and as these active compounds belong to different chemical classes, also different chromatographic and electrophoretic methods coupled with various detectors (the most used diode array detector and mass spectrometer) have to be performed. This review covers recent steps made in the fundamental understanding of sample preparation methods as well as of analytical tools useful for the complete characterization of bioactive food compounds. The most commonly used methods for extraction of natural antimicrobial compounds are the conventional liquid-liquid or solid-liquid extraction and the modern techniques such as pressurized liquid extraction, microwave-assisted extraction, ultrasound-assisted extraction, solid-phase micro-extraction, supercritical fluid extraction, and matrix solid phase dispersion. The complete characterization of the compounds is achieved using both monodimensional chromatographic processes (LC, nano-LC, GC, and CE coupled with different type of detectors) and, recently, using comprehensive two-dimensional systems (LC×LC and GC×GC). Copyright © 2011 Elsevier Ltd. All rights reserved.
Chen, Zhi; Zhang, Wei; Wang, Liping; Fan, Huajun; Wan, Qiang; Wu, Xuehao; Tang, Xunyou; Tang, James Z
2015-09-01
A novel method for chiral separation of flurbiprofen enantiomers was developed using aqueous two-phase extraction (ATPE) coupled with biphasic recognition chiral extraction (BRCE). An aqueous two-phase system (ATPS) was used as an extracting solvent which was composed of ethanol (35.0% w/w) and ammonium sulfate (18.0% w/w). The chiral selectors in ATPS for BRCE consideration were L-dioctyl tartrate and L-tryptophan, which were screened from amino acids, β-cyclodextrin derivatives, and L-tartrate esters. Factors such as the amounts of L-dioctyl tartrate and L-tryptophan, pH, flurbiprofen concentration, and the operation temperature were investigated in terms of chiral separation of flurbiprofen enantiomers. The optimum conditions were as follows: L-dioctyl tartrate, 80 mg; L-tryptophan, 40 mg; pH, 4.0; flurbiprofen concentration, 0.10 mmol/L; and temperature, 25 °C. The maximum separation factor α for flurbiprofen enantiomers could reach 2.34. The mechanism of chiral separation of flurbiprofen enantiomers is discussed and studied. The results showed that synergistic extraction has been established by L-dioctyl tartrate and L-tryptophan, which enantioselectively recognized R- and S-enantiomers in top and bottom phases, respectively. Compared to conventional liquid-liquid extraction, ATPE coupled with BRCE possessed higher separation efficiency and enantioselectivity without the use of any other organic solvents. The proposed method is a potential and powerful alternative to conventional extraction for separation of various enantiomers. © 2015 Wiley Periodicals, Inc.
Fluidics platform and method for sample preparation
Benner, Henry W.; Dzenitis, John M.
2016-06-21
Provided herein are fluidics platforms and related methods for performing integrated sample collection and solid-phase extraction of a target component of the sample all in one tube. The fluidics platform comprises a pump, particles for solid-phase extraction and a particle-holding means. The method comprises contacting the sample with one or more reagents in a pump, coupling a particle-holding means to the pump and expelling the waste out of the pump while the particle-holding means retains the particles inside the pump. The fluidics platform and methods herein described allow solid-phase extraction without pipetting and centrifugation.
Data is presented on the development of a new automated system combining solid phase extraction (SPE) with GC/MS spectrometry for the single-run analysis of water samples containing a broad range of organic compounds. The system uses commercially available automated in-line 10-m...
Wang, Z; Hennion, B; Urruty, L; Montury, M
2000-11-01
Solid-phase microextraction coupled with high performance liquid chromatography has been studied for the analysis of methiocarb, napropamide, fenoxycarb and bupirimate in strawberries. The strawberries were blended and centrifuged. Then, an aliquot of the resulting extracting solution was subjected to solid-phase microextraction (SPME) on a 60 microns polydimethylsiloxane/divinylbenzene (PDMS/DVB) fibre for 45 min at room temperature. The extracted pesticides on the SPME fibre were desorbed into SPME/high performance liquid chromatography (HPLC) interface for HPLC analysis with diode-array detection (DAD). The method is organic solvent-free for the whole extraction process and is simple and easy to manipulate. The detection limits were shown to be at low microgram kg-1 level and the linear response covered the range from 0.05 to 2 mg kg-1 of pesticides in strawberries with a regression coefficient larger than 0.99. A good repeatability with RSDs between 2.92 and 9.25% was obtained, depending on compounds.
Huang, Juan; Chen, Guosong; Zhang, Xiaoyan; Shen, Chongyu; Lü, Chen; Wu, Bin; Liu, Yan; Chen, Huilan; Ding, Tao
2012-11-01
A method was established for the determination of deoxynivalenol (vomitoxin) in grain and its products based on solid-phase extraction coupled with high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS). The sample was firstly extracted by acetonitrile-water (84:16, v/v). The extract was then cleaned-up by an HLB solid phase extraction cartridge. The separation was carried out on a Phenomenex Kinetex C18 column (100 mm x4. 6 mm, 2.6 microm) with a gradient elution using 0.3% per hundred ammonia solution-acetonitrile as mobile phases. The analysis of deoxynivalenol was performed under electrospray negative ionization mode. The limit of detection (LOD, S/N= 3) and the limit of quantification (LOQ, S/N = 10) were 20 microg/kg and 50 microg/kg, respectively. A good linearity (r > 0.99) was achieved for the target compound over the range of 20-1000 pg/L. The recoveries at the three spiked levels (50, 100, 500 microg/kg) in the blank matrices such as flour, barley, soybean, rice, cornmeal, cassava and wheat, were varied from 75.6% to 111.0% with the relative standard deviations no more than 13. 0%. The method is accurate, efficient, sensitive and practical. The cost of pretreatment is obviously reduced by replacing immunoaffinity columns and Mycosep columns with HLB columns which have the same purification effect.
Data is presented showing the progress made towards the development of a new automated system combining solid phase extraction (SPE) with gas chromatography/mass spectrometry for the single run analysis of water samples containing a broad range of acid, base and neutral compounds...
Ma, Yan; Xie, Jiawen; Jin, Jing; Wang, Wei; Yao, Zhijian; Zhou, Qing; Li, Aimin; Liang, Ying
2015-07-01
A novel magnetic solid phase extraction coupled with high-performance liquid chromatography method was established to analyze polyaromatic hydrocarbons in environmental water samples. The extraction conditions, including the amount of extraction agent, extraction time, pH and the surface structure of the magnetic extraction agent, were optimized. The results showed that the amount of extraction agent and extraction time significantly influenced the extraction performance. The increase in the specific surface area, the enlargement of pore size, and the reduction of particle size could enhance the extraction performance of the magnetic microsphere. The optimized magnetic extraction agent possessed a high surface area of 1311 m(2) /g, a large pore size of 6-9 nm, and a small particle size of 6-9 μm. The limit of detection for phenanthrene and benzo[g,h,i]perylene in the developed analysis method was 3.2 and 10.5 ng/L, respectively. When applied to river water samples, the spiked recovery of phenanthrene and benzo[g,h,i]perylene ranged from 89.5-98.6% and 82.9-89.1%, respectively. Phenanthrene was detected over a concentration range of 89-117 ng/L in three water samples withdrawn from the midstream of the Huai River, and benzo[g,h,i]perylene was below the detection limit. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Narukawa, Tomohiro; Chiba, Koichi; Sinaviwat, Savarin; Feldmann, Jörg
2017-01-06
A new rapid monitoring method by means of high performance liquid chromatography-inductively coupled plasma mass spectrometry (HPLC-ICP-MS) following the heat-assisted extraction was developed for measurement of total inorganic arsenic species in rice flour. As(III) and As(V) eluted at the same retention time and completely separated from organoarsenic species by an isocratic elution program on a reversed phase column. Therefore, neither ambiguous oxidation of arsenite to arsenate nor the integration of two peaks were necessary to determine directly the target analyte inorganic arsenic. Rapid injection allowed measuring 3 replicates within 6min and this combined with a quantitative extraction of all arsenic species from rice flour by a 15min HNO 3 -H 2 O 2 extraction makes this the fastest laboratory based method for inorganic arsenic in rice flour. Copyright © 2016 Elsevier B.V. All rights reserved.
Yang, Liu; Han, Qiang; Cao, Shuya; Yang, Jie; Yang, Junchao; Ding, Mingyu
2014-01-01
On-site analysis is an efficient approach to facilitate analysis at the location of the system under investigation as it can result in more accurate, more precise and quickly available analytical data. In our work, a novel self-made thermal desorption based interface was fabricated to couple solid-phase microextraction with ion mobility spectrometry for on-site water analysis. The portable interface can be connected with the front-end of an ion mobility spectrometer directly without other modifications. The analytical performance was evaluated via the extraction of chemical warfare agents and simulants in water samples. Several parameters including ionic strength and extraction time have been investigated in detail. The application of the developed method afforded satisfactory recoveries ranging from 72.9% to 114.4% when applied to the analysis of real water samples. PMID:25384006
Han, Juan; Wang, Yun; Liu, Yan; Li, Yanfang; Lu, Yang; Yan, Yongsheng; Ni, Liang
2013-02-01
Ionic liquid-salt aqueous two-phase extraction coupled with high-performance liquid chromatography with ultraviolet detection was developed for the determination of sulfonamides in water and food samples. In the procedure, the analytes were extracted from the aqueous samples into the ionic liquid top phase in one step. Three sulfonamides, sulfamerazine, sulfamethoxazole, and sulfamethizole were selected here as model compounds for developing and evaluating the method. The effects of various experimental parameters in extraction step were studied using two optimization methods, one variable at a time and Box-Behnken design. The results showed that the amount of sulfonamides did not have effect on the extraction efficiency. Therefore, a three-level Box-Behnken experimental design with three factors, which combined the response surface modeling, was used to optimize sulfonamides extraction. Under the most favorable extraction parameters, the detection limits (S/N = 3) and quantification limits (S/N = 10) of the proposed method for the target compounds were achieved within the range of 0.15-0.3 ng/mL and 0.5-1.0 ng/mL from spiked samples, respectively, which are lower than or comparable with other reported approaches applied to the determination of the same compounds. Finally, the proposed method was successfully applied to the determination of sulfonamide compounds in different water and food samples and satisfactory recoveries of spiked target compounds in real samples were obtained.
Sanagi, Mohd Marsin; Miskam, Mazidatulakmam; Wan Ibrahim, Wan Aini; Hermawan, Dadan; Aboul-Enein, Hassan Y
2010-07-01
A three-phase hollow fiber liquid-phase microextraction method coupled with CE was developed and used for the determination of partition coefficients and analysis of selected nitrophenols in water samples. The selected nitrophenols were extracted from 14 mL of aqueous solution (donor solution) with the pH adjusted to pH 3 into an organic phase (1-octanol) immobilized in the pores of the hollow fiber and finally backextracted into 40.0 microL of the acceptor phase (NaOH) at pH 12.0 located inside the lumen of the hollow fiber. The extractions were carried out under the following optimum conditions: donor solution, 0.05 M H(3)PO(4), pH 3.0; organic solvent, 1-octanol; acceptor solution, 40 microL of 0.1 M NaOH, pH 12.0; agitation rate, 1050 rpm; extraction time, 15 min. Under optimized conditions, the calibration curves for the analytes were linear in the range of 0.05-0.30 mg/L with r(2)>0.9900 and LODs were in the range of 0.01-0.04 mg/L with RSDs of 1.25-2.32%. Excellent enrichment factors of up to 398-folds were obtained. It was found that the partition coefficient (K(a/d)) values were high for 2-nitrophenol, 3-nitrophenol, 4-nitrophenol, 2,4-dinitrophenol and 2,6-dinitrophenol and that the individual partition coefficients (K(org/d) and K(a/org)) promoted efficient simultaneous extraction from the donor through the organic phase and further into the acceptor phase. The developed method was successfully applied for the analysis of water samples.
Torres Padrón, M E; Sosa Ferrera, Z; Santana Rodríguez, J J
2006-09-01
A solid-phase microextraction (SPME) procedure using two commercial fibers coupled with high-performance liquid chromatography (HPLC) is presented for the extraction and determination of organochlorine pesticides in water samples. We have evaluated the extraction efficiency of this kind of compound using two different fibers: 60-mum polydimethylsiloxane-divinylbenzene (PDMS-DVB) and Carbowax/TPR-100 (CW/TPR). Parameters involved in the extraction and desorption procedures (e.g. extraction time, ionic strength, extraction temperature, desorption and soaking time) were studied and optimized to achieve the maximum efficiency. Results indicate that both PDMS-DVB and CW/TPR fibers are suitable for the extraction of this type of compound, and a simple calibration curve method based on simple aqueous standards can be used. All the correlation coefficients were better than 0.9950, and the RSDs ranged from 7% to 13% for 60-mum PDMS-DVB fiber and from 3% to 10% for CW/TPR fiber. Optimized procedures were applied to the determination of a mixture of six organochlorine pesticides in environmental liquid samples (sea, sewage and ground waters), employing HPLC with UV-diode array detector.
Tsai, Wen-Hsien; Huang, Tzou-Chi; Chen, Ho-Hsien; Wu, Yuh-Wern; Huang, Joh-Jong; Chuang, Hung-Yi
2010-01-15
A salting-out assisted liquid extraction coupled with back-extraction by a water/acetonitrile/dichloromethane ternary component system combined with high-performance liquid chromatography with diode-array detection (HPLC-DAD) was developed for the extraction and determination of sulfonamides in solid tissue samples. After the homogenization of the swine muscle with acetonitrile and salt-promoted partitioning, an aliquot of 1 mL of the acetonitrile extract containing a small amount of dichloromethane (250-400 microL) was alkalinized with diethylamine. The clear organic extract obtained by centrifugation was used as a donor phase and then a small amount of water (40-55 microL) could be used as an acceptor phase to back-extract the analytes in the water/acetonitrile/dichloromethane ternary component system. In the back-extraction procedure, after mixing and centrifuging, the sedimented phase would be water and could be withdrawn easily into a microsyringe and directly injected into the HPLC system. Under the optimal conditions, recoveries were determined for swine muscle fortified at 10 ng/g and quantification was achieved by matrix-matched calibration. The calibration curves of five sulfonamides showed linearity with the coefficient of estimation above 0.998. Relative recoveries for the analytes were all from 96.5 to 109.2% with relative standard deviation of 2.7-4.0%. Preconcentration factors ranged from 16.8 to 30.6 for 1 mL of the acetonitrile extract. Limits of detection ranged from 0.2 to 1.0 ng/g. 2009 Elsevier B.V. All rights reserved.
Yang, Rui; Liu, Yuxin; Yan, Xiangyang; Liu, Shaomin
2016-12-01
A rapid, sensitive and accurate method for the simultaneous extraction and determination of five types of trace phthalate esters (PAEs) in environmental water and beverage samples using magnetic molecularly imprinted solid-phase extraction (MMIP-SPE) coupled with gas chromatography-mass spectrometry (GC-MS) was developed. A novel type of molecularly imprinted polymers on the surface of yolk-shell magnetic mesoporous carbon (Fe 3 O 4 @void@C-MIPs) was used as an efficient adsorbent for selective adsorption of phthalate esters based on magnetic solid-phase extraction (MSPE). The real samples were first preconcentrated by Fe 3 O 4 @void@C-MIPs, subsequently extracted by eluent and finally determined by GC-MS after magnetic separation. Several variables affecting the extraction efficiency of the analytes, including the type and volume of the elution solvent, amount of adsorbent, extraction time, desorption time and pH of the sample solution, were investigated and optimized. Validation experiments indicated that the developed method presented good linearity (R 2 >0.9961), satisfactory precision (RSD<6.7%), and high recovery (86.1-103.1%). The limits of detection ranged from 1.6ng/L to 5.2ng/L and the enrichment factor was in the range of 822-1423. The results indicated that the novel method had the advantages of convenience, good sensitivity, and high efficiency, and it could also be successfully applied to the analysis of PAEs in real samples. Copyright © 2016. Published by Elsevier B.V.
Li, Lan-Jie; Jin, Yong-Ri; Wang, Xiao-Zhong; Liu, Ying; Wu, Qian; Shi, Xiao-Lei; Li, Xu-Wen
2015-09-01
A method of ionic liquid salt aqueous two-phase extraction coupled with high-performance liquid chromatography has been developed for the analysis of seven rare ginsenosides including Rg6 , F4 , 20(S)-Rg3 , 20(R)-Rg3 , Rk3 , Rk1 , and Rg5 in Xue-Sai-Tong injection. The injection was mixed with ionic liquid 1-butyl-3-methylimidazolium bromide aqueous solution, and a mixture was obtained. With the addition of sodium dodecyl sulfate and dipotassium phosphate into the mixture, the aqueous two-phase mixture was formed after ultrasonic treatment and centrifuged. Rare ginsenosides were extracted into the upper phase. To obtain a high extraction factors, various influences were considered systematically, such as the volume of ionic liquid, the category and amount of salts, the amount of sodium dodecyl sulfate, the pH value of system, and the time of ultrasonic treatment. Under the optimal condition, rare ginsenosides in Xue-Sai-Tong injection were enriched and detected, the recoveries of seven rare ginsenosides ranged from 90.05 to 112.55%, while relative standard deviations were lower than 2.50%. The developed method was reliable, rapid and sensitive for the determination of seven rare ginsenosides in the injections. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Behrens, Beate; Engelen, Jeannine; Tiso, Till; Blank, Lars Mathias; Hayen, Heiko
2016-04-01
Rhamnolipids are surface-active agents with a broad application potential that are produced in complex mixtures by bacteria of the genus Pseudomonas. Analysis from fermentation broth is often characterized by laborious sample preparation and requires hyphenated analytical techniques like liquid chromatography coupled to mass spectrometry (LC-MS) to obtain detailed information about sample composition. In this study, an analytical procedure based on chromatographic method development and characterization of rhamnolipid sample material by LC-MS as well as a comparison of two sample preparation methods, i.e., liquid-liquid extraction and solid-phase extraction, is presented. Efficient separation was achieved under reversed-phase conditions using a mixed propylphenyl and octadecylsilyl-modified silica gel stationary phase. LC-MS/MS analysis of a supernatant from Pseudomonas putida strain KT2440 pVLT33_rhlABC grown on glucose as sole carbon source and purified by solid-phase extraction revealed a total of 20 congeners of di-rhamnolipids, mono-rhamnolipids, and their biosynthetic precursors 3-(3-hydroxyalkanoyloxy)alkanoic acids (HAAs) with different carbon chain lengths from C8 to C14, including three rhamnolipids with uncommon C9 and C11 fatty acid residues. LC-MS and the orcinol assay were used to evaluate the developed solid-phase extraction method in comparison with the established liquid-liquid extraction. Solid-phase extraction exhibited higher yields and reproducibility as well as lower experimental effort.
Rosero-Moreano, Milton; Canellas, Elena; Nerín, Cristina
2014-02-01
The present study deals with the development of a liquid microextraction procedure for enhancing the sensitivity of the determination of 2-methyl-4-isothiazolin-3-one and 5-chloro-2-methyl-4-isothiazolin-3-one in adhesives. The procedure involves a three-phase hollow-fiber liquid-phase microextraction using a semipermeable polypropylene membrane, which contained 1-octanol as the organic phase in the pores of the membrane. The donor and acceptor phases are aqueous acidic and alkaline media, respectively, and the final liquid phase (acceptor) is analyzed by HPLC coupled with diode array detection. The most appropriate conditions were extraction time 20 min, stirring speed 1400 rpm, extraction temperature 50°C. The quantification limits of the method were 0.123 and 0.490 μg/g for 2-methyl-4-isothiazolin-3-one and 5-chloro-2-methyl-4-isothiazolin-3-one, respectively. Three different adhesive samples were successfully analyzed. The procedure was compared to direct analysis using ultra high pressure liquid chromatography coupled with TOF-MS, where the identification of the compounds and the quantification values were confirmed. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Chen, LiQin; Wang, Hui; Xu, Zhen; Zhang, QiuYue; Liu, Jia; Shen, Jun; Zhang, WanQi
2018-08-03
In the present study, we developed a simple and high-throughput solid phase extraction (SPE) procedure for selective extraction of catecholamines (CAs) in urine samples. The SPE adsorbents were electrospun composite fibers functionalized with 4-carboxybenzo-18-crown-6 ether modified XAD resin and polystyrene, which were packed into 96-well columns and used for high-throughput selective extraction of CAs in healthy human urine samples. Moreover, the extraction efficiency of packed-fiber SPE (PFSPE) was examined by high performance liquid chromatography coupled with fluorescence detector. The parameters affecting the extraction efficiency and impurity removal efficiency were optimized, and good linearity ranging from 0.5 to 400 ng/mL was obtained with a low limit of detection (LOD, 0.2-0.5 ng/mL) and a good repeatability (2.7%-3.7%, n = 6). The extraction recoveries of three CAs ranged from 70.5% to 119.5%. Furthermore, stable and reliable results obtained by the fluorescence detector were superior to those obtained by the electrochemical detector. Collectively, PFSPE coupled with 96-well columns was a simple, rapid, selective, high-throughput and cost-efficient method, and the proposed method could be applied in clinical chemistry. Copyright © 2018 Elsevier B.V. All rights reserved.
Chen, Songqing; Qin, Xingxiu; Gu, Weixi; Zhu, Xiashi
2016-12-01
Ionic liquids-β-cyclodextrin polymer (ILs-β-CDCP) was attached on Fe 3 O 4 nanoparticles to prepare magnetic solid phase extraction agent (Fe 3 O 4 @ILs-β-CDCP). The properties and morphology of Fe 3 O 4 @ILs-β-CDCP were characterized by Fourier transform infrared spectroscopy (FTIR), scanning electron microscopy (SEM), transmission electron microscopy (TEM), X-ray diffraction(XRD), size distribution and magnetic analysis. A new method of magnetic solid phase extraction (MSPE) coupled to ICP-OES for the speciation of Mn(II)/Mn(VII) in water samples was established. The results showed that Mn(VII) and total manganese [Mn(II)+Mn(VII)] were quantitatively extracted after adjusting aqueous sample solution to pH 6.0 and 10.0, respectively. Mn(II) was calculated by subtraction of Mn(VII) from total manganese. Fe 3 O 4 @ILs-β-CDCP showed a higher adsorption capacity toward Mn(II) and Mn(VII). Several factors, such as the pH value, extraction temperature and sample volume, were optimized to achieve the best extraction efficiency. Moreover, the adsorption ability of Fe 3 O 4 @ILs-β-CDCP would not be significantly lower after reusing of 10 times. The accuracy of the developed method was confirmed by analyzing certified reference materials (GSB 07-1189-2000), and by spiking spring water, city water and lake water samples. Copyright © 2016 Elsevier B.V. All rights reserved.
Developments in coupled solid-phase extraction-capillary electrophoresis 2013-2015.
Ramautar, Rawi; Somsen, Govert W; de Jong, Gerhardus J
2016-01-01
An overview of the design and application of coupled solid-phase extraction-capillary electrophoresis (SPE-CE) systems reported in the literature between July 2013 and June 2015 is provided in this paper. The present article is a continuation of our previous review papers on this topic which covered the time period 2000-2013 (Electrophoresis 2008, 29, 108-128; Electrophoresis 2010, 31, 44-54; Electrophoresis 2012, 33, 243-250; Electrophoresis 2014, 35, 128-137). The use of in-line and on-line SPE-CE approaches is treated and outlined in this review. Recent advancements, such as, for example, the use of aptamers as affinity material for in-line SPE-CE, the use of a bead string design for in-line fritless SPE-CE, and new interfacing techniques for the on-line coupling of SPE to CE, are outlined. Selected examples demonstrate the applicability of the coupled SPE-CE systems for biomedical, pharmaceutical, environmental, and food studies. A complete overview of the recent SPE-CE studies is given in table format, providing information on sample type, SPE sorbent, coupling mode, detection mode, and LOD. Finally, some general conclusions and perspectives are provided. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Chu, Chu; Wei, Mengmeng; Wang, Shan; Zheng, Liqiong; He, Zheng; Cao, Jun; Yan, Jizhong
2017-09-15
A simple and effective method was developed for determining lignans in Schisandrae Chinensis Fructus by using a micro-matrix solid phase dispersion (MSPD) technique coupled with microemulsion electrokinetic chromatography (MEEKC). Molecular sieve, TS-1, was applied as a solid supporting material in micro MSPD extraction for the first time. Parameters that affect extraction efficiency, such as type of dispersant, mass ratio of the sample to the dispersant, grinding time, elution solvent and volume were optimized. The optimal extraction conditions involve dispersing 25mg of powdered Schisandrae samples with 50mg of TS-1 by a mortar and pestle. A grinding time of 150s was adopted. The blend was then transferred to a solid-phase extraction cartridge and the target analytes were eluted with 500μL of methanol. Moreover, several parameters affecting MEEKC separation were studied, including the type of oil, SDS concentration, type and concentration of cosurfactant, and concentration of organic modifier. A satisfactory linearity (R>0.9998) was obtained, and the calculated limits of quantitation were less than 2.77μg/mL. Finally, the micro MSPD-MEEKC method was successfully applied to the analysis of lignans in complex Schisandrae fructus samples. Copyright © 2017 Elsevier B.V. All rights reserved.
Zhang, Zhen; Liu, Fang; He, Caian; Yu, Yueli; Wang, Min
2017-12-01
Application of an aqueous two-phase system (ATPS) coupled with ultrasonic technology for the extraction of phloridzin from Malus micromalus Makino was evaluated and optimized by response surface methodology (RSM). The ethanol/ammonium sulfate ATPS was selected for detailed investigation, including the phase diagram, effect of phase composition and extract conditions on the partition of phloridzin, and the recycling of ammonium sulfate. In addition, the evaluation of extraction efficiency and the identification of phloridzin were investigated. The optimal partition coefficient (6.55) and recovery (92.86%) of phloridzin were obtained in a system composed of 35% ethanol (w/w) and 16% (NH 4 ) 2 SO 4 (w/w), 51:1 liquid-to-solid ratio, and extraction temperature of 36 °C. Comparing with the traditional solvent extraction with respective 35% and 80% ethanol, ultrasonic-assisted aqueous two-phase extraction (UAATPE) strategy had significant advantages with lower ethanol consumption, less impurity of sugar and protein, and higher extracting efficiency of phloridzin. Our result indicated that UAATPE was a valuable method for the extraction and preliminary purification of phloridzin from the fruit of Malus micromalus Makino, which has great potential in the deep processing of Malus micromalus Makino industry to increase these fruits' additional value and drive the local economic development. © 2017 Institute of Food Technologists®.
Sun, Ting; Li, Xuwen; Yang, Jie; Li, Lanjie; Jin, Yongri; Shi, Xiaolei
2015-06-01
In this study, graphene-encapsulated silica was synthesized by a hydrothermal reduction strategy. The presence of silica in graphene was identified by Fourier-transform infrared spectrometry, X-ray diffraction and scanning electron microscopy. The graphene-encapsulated silica subsequently was used as adsorbent for matrix solid-phase dispersion extraction of poly-methoxylated flavonoids from the dried leaves of Murraya panaculata (L.) Jack. Compared with the other adsorbents (graphene, silica gel, C18 silica, neutral alumina, diatomaceous earth) and without any adsorbents, better results were obtained. Then a method for analysis of poly-methoxylated flavonoids was established by coupling matrix solid-phase dispersion extraction with ultra high performance liquid chromatography and UV detection. Compared with reflux extraction and ultrasonic extraction, the proposed method is quicker, more efficient and more environmental protection. Less than 10 min is needed from extraction to detection. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Qiao, Jindong; Wang, Mingyu; Yan, Hongyuan; Yang, Gengliang
2014-04-02
A new magnetic dummy molecularly imprinted dispersive solid-phase extraction (MAG-MIM-dSPE) coupled with gas chromatography-FID was developed for selective determination of phthalates in plastic bottled beverages. The new magnetic dummy molecularly imprinted microspheres (MAG-MIM) using diisononyl phthalate as a template mimic were synthesized by coprecipitation coupled with aqueous suspension polymerization and were successfully applied as the adsorbents for MAG-MIM-dSPE to extract and isolate five phthalates from plastic bottled beverages. Validation experiments showed that the MAG-MIM-dSPE method had good linearity at 0.0040-0.40 μg/mL (0.9991-0.9998), good precision (3.1-6.9%), and high recovery (89.5-101.3%), and limits of detection were obtained in a range of 0.53-1.2 μg/L. The presented MAG-MIM-dSPE method combines the quick separation of magnetic particles, special selectivity of MIM, and high extraction efficiency of dSPE, which could potentially be applied to selective screening of phthalates in beverage products.
Zheng, Zhenjia; Zhao, Xian-En; Zhu, Shuyun; Dang, Jun; Qiao, Xuguang; Qiu, Zhichang; Tao, Yanduo
2018-04-18
Simultaneous detection of oleanolic acid and ursolic acid in rat blood by in vivo microdialysis can provide important pharmacokinetics information. Microwave-assisted derivatization coupled with magnetic dispersive solid phase extraction was established for the determination of oleanolic acid and ursolic acid by liquid chromatography tandem mass spectrometry. 2'-Carbonyl-piperazine rhodamine B was first designed and synthesized as the derivatization reagent, which was easily adsorbed onto the surface of Fe 3 O 4 /graphene oxide. Simultaneous derivatization and extraction of oleanolic acid and ursolic acid were performed on Fe 3 O 4 /graphene oxide. The permanent positive charge of the derivatization reagent significantly improved the ionization efficiencies. The limits of detection were 0.025 and 0.020 ng/mL for oleanolic acid and ursolic acid, respectively. The validated method was shown to be promising for sensitive, accurate, and simultaneous determination of oleanolic acid and ursolic acid. It was used for their pharmacokinetics study in rat blood after oral administration of Arctiumlappa L. root extract.
Farajzadeh, Mir Ali; Bamorowat, Mahdi; Mogaddam, Mohammad Reza Afshar
2016-11-01
An efficient, reliable, sensitive, rapid, and green analytical method for the extraction and determination of neonicotinoid insecticides in aqueous samples has been developed using ionic liquid phase microextraction coupled with high performance liquid chromatography-diode array detector. In this method, a few microliters of 1-hexyl-3-methylimidazolium hexafluorophosphate (as an extractant) is added onto a ringer tablet and it is transferred into a conical test tube containing aqueous phase of the analytes. By manually shaking, the ringer tablet is dissolved and the extractant is released into the aqueous phase as very tiny droplets to provide a cloudy solution. After centrifuging the extracted analytes into ionic liquid are collected at the bottom of a conical test tube. Under the optimum extraction conditions, the method showed low limits of detection and quantification between 0.12 and 0.33 and 0.41 and 1.11ngmL(-1), respectively. Extraction recoveries and enrichment factors were from 66% to 84% and 655% to 843%, respectively. Finally different aqueous samples were successfully analyzed using the proposed method. Copyright © 2016 Elsevier B.V. All rights reserved.
Hinsmann, P; Arce, L; Ríos, A; Valcárcel, M
2000-01-07
The separation of seven pesticides by micellar electrokinetic capillary chromatography in spiked water samples is described, allowing the analysis of pesticides mixtures down to a concentration of 50 microg l(-1) in less than 13 min. Calibration, pre-concentration, elution and injection into the sample vial was carried out automatically by a continuous flow system (CFS) coupled to a capillary electrophoresis system via a programmable arm. The whole system was electronically coupled by a micro-processor and completely controlled by a computer. A C18 solid-phase mini-column was used for the pre-concentration, allowing a 12-fold enrichment (as an average value) of the pesticides from fortified water samples. Under the optimal extraction conditions, recoveries between 90 and 114% for most of the pesticides were obtained.
Kress, Daniel; Egelhaaf, Martin
2014-01-01
During locomotion animals rely heavily on visual cues gained from the environment to guide their behavior. Examples are basic behaviors like collision avoidance or the approach to a goal. The saccadic gaze strategy of flying flies, which separates translational from rotational phases of locomotion, has been suggested to facilitate the extraction of environmental information, because only image flow evoked by translational self-motion contains relevant distance information about the surrounding world. In contrast to the translational phases of flight during which gaze direction is kept largely constant, walking flies experience continuous rotational image flow that is coupled to their stride-cycle. The consequences of these self-produced image shifts for the extraction of environmental information are still unclear. To assess the impact of stride-coupled image shifts on visual information processing, we performed electrophysiological recordings from the HSE cell, a motion sensitive wide-field neuron in the blowfly visual system. This cell has been concluded to play a key role in mediating optomotor behavior, self-motion estimation and spatial information processing. We used visual stimuli that were based on the visual input experienced by walking blowflies while approaching a black vertical bar. The response of HSE to these stimuli was dominated by periodic membrane potential fluctuations evoked by stride-coupled image shifts. Nevertheless, during the approach the cell’s response contained information about the bar and its background. The response components evoked by the bar were larger than the responses to its background, especially during the last phase of the approach. However, as revealed by targeted modifications of the visual input during walking, the extraction of distance information on the basis of HSE responses is much impaired by stride-coupled retinal image shifts. Possible mechanisms that may cope with these stride-coupled responses are discussed. PMID:25309362
Chen, Zhi; Zhang, Wei; Tang, Xunyou; Fan, Huajun; Xie, Xiujuan; Wan, Qiang; Wu, Xuehao; Tang, James Z
2016-06-25
A novel and rapid method for simultaneous extraction and separation of the different polysaccharides from Semen Cassiae (SC) was developed by microwave-assisted aqueous two-phase extraction (MAATPE) in a one-step procedure. Using ethanol/ammonium sulfate system as a multiphase solvent, the effects of MAATPE on the extraction of polysaccharides from SC such as the composition of the ATPS, extraction time, temperature and solvent-to-material ratio were investigated by UV-vis analysis. Under the optimum conditions, the yields of polysaccharides were 4.49% for the top phase, 8.80% for the bottom phase and 13.29% for total polysaccharides, respectively. Compared with heating solvent extraction and ultrasonic assisted extraction, MAATPE exhibited the higher extraction yields in shorter time. Fourier-transform infrared spectra showed that two polysaccharides extracted from SC to the top and bottom phases by MAATPE were different from each other in their chemical structures. Through acid hydrolysis and PMP derivatization prior to HPLC, analytical results by indicated that a polysaccharide of the top phases was a relatively homogeneous homepolysaccharide composed of dominant gucose glucose while that of the bottom phase was a water-soluble heteropolysaccharide with multiple components of glucose, xylose, arabinose, galactose, mannose and glucuronic acid. Molar ratios of monosaccharides were 95.13:4.27:0.60 of glucose: arabinose: galactose for the polysaccharide from the top phase and 62.96:14.07:6.67: 6.67:5.19:4.44 of glucose: xylose: arabinose: galactose: mannose: glucuronic acid for that from the bottom phase, respectively. The mechanism for MAATPE process was also discussed in detail. MAATPE with the aid of microwave and the selectivity of the ATPS not only improved yields of the extraction, but also obtained a variety of polysaccharides. Hence, it was proved as a green, efficient and promising alternative to simultaneous extraction of polysaccharides from SC. Copyright © 2016 Elsevier Ltd. All rights reserved.
Vavrouš, Adam; Pavloušková, Jana; Ševčík, Václav; Vrbík, Karel; Čabala, Radomír
2016-07-22
Worldwide production of phthalates has led to their undesirable presence in the food chain. Particularly edible oils have become an area of growing concern owing to numerous reported occurrences of phthalates. The analytical methods used in this field face difficulties associated mainly with matrix complexity or phthalate contamination which this study has aimed to describe and resolve. The proposed procedure consisting of liquid-liquid extraction, solid phase extraction and high performance liquid chromatography coupled with tandem mass spectrometry allowed us to analyze simultaneously 6 individual phthalates and 2 phthalate isomeric mixtures. DSC-18 SPE phase was selected for cleanup owing to the most efficient co-extract removal (assessed using high resolution mass spectrometry). Several sources of phthalate contamination were identified, however, the mobile phase was the most serious. The key improvement was achieved by equipping a contamination trap, a 50-mm reverse phase HPLC column, generating a delay between target and mobile phase peaks of the same compounds. RSDs ranging between 2.4 and 16 % confirm good precision and LOQs between 5.5 and 110μgkg(-1) reflect satisfactory blank management. With up to 19 occurrences in 25 analyzed edible oil samples and levels up to 33mgkg(-1), bis(2-ethylhexyl), diisononyl and diisodecyl phthalates were the most important contaminants. Copyright © 2016 Elsevier B.V. All rights reserved.
Li, Jian; Chen, Tian; Wang, Yuwei; Shi, Zhixiong; Zhou, Xianqing; Sun, Zhiwei; Wang, Dejun; Wu, Yongning
2017-02-01
Two simplified sample preparation procedures for simultaneous extraction and clean-up of tetrabromobisphenol A, α-, β-, and γ-hexabromocyclododecane and polybrominated diphenyl ethers in human serum were developed and validated. The first procedure was based on solid-phase extraction. Sample extraction, purification, and lipid removal were carried out directly on an Oasis HLB cartridge. The second procedure was a quick, easy, cheap, effective, rugged, and safe-based approach using octadecyl-modified silica particles as a sorbent. After sample extraction and cleanup, tetrabromobisphenol A/hexabromocyclododecane was separated from polybrominated diphenyl ethers by using a Si-based cartridge. Tetrabromobisphenol A and hexabromocyclododecane were then detected by high-performance liquid chromatography coupled to tandem mass spectrometry, while polybrominated diphenyl ethers were detected by gas chromatography coupled to tandem mass spectrometry. The results of the spike recovery test using fetal bovine serum showed that the average recoveries of the analytes ranged from 87.3 to 115.3% with relative standard deviations equal to or lower than 13.4 %. Limits of detection of the analytes were in the range of 0.4-19 pg/mL except for decabromodiphenyl ether. The developed method was successfully applied to routine analysis of human serum samples from occupational workers and the general population. Extremely high serum polybrominated diphenyl ethers levels up to 3.32 × 10 4 ng/g lipid weight were found in occupational workers. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Using nonequilibrium dynamics to probe competing orders in a Mott-Peierls system
Wang, Y.; Moritz, B.; Chen, C. -C.; ...
2016-02-24
Competition between ordered phases, and their associated phase transitions, are significant in the study of strongly correlated systems. Here, we examine one aspect, the nonequilibrium dynamics of a photoexcited Mott-Peierls system, using an effective Peierls-Hubbard model and exact diagonalization. Near a transition where spin and charge become strongly intertwined, we observe antiphase dynamics and a coupling-strength-dependent suppression or enhancement in the static structure factors. The renormalized bosonic excitations coupled to a particular photoexcited electron can be extracted, which provides an approach for characterizing the underlying bosonic modes. The results from this analysis for different electronic momenta show an uneven softeningmore » due to a stronger coupling near k F. As a result, this behavior reflects the strong link between the fermionic momenta, the coupling vertices, and ultimately, the bosonic susceptibilities when multiple phases compete for the ground state of the system.« less
Phase locking of vortex cores in two coupled magnetic nanopillars
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhu, Qiyuan; Liu, Xianyin; Zheng, Qi
2014-11-15
Phase locking dynamics of the coupled vortex cores in two identical magnetic spin valves induced by spin-polarized current are studied by means of micromagnetic simulations. Our results show that the available current range of phase locking can be expanded significantly by the use of constrained polarizer, and the vortices undergo large orbit motions outside the polarization areas. The effects of polarization areas and dipolar interaction on the phase locking dynamics are studied systematically. Phase locking parameters extracted from simulations are discussed by theoreticians. The dynamics of vortices influenced by spin valve geometry and vortex chirality are discussed at last. Thismore » work provides deeper insights into the dynamics of phase locking and the results are important for the design of spin-torque nano-oscillators.« less
Romarís-Hortas, Vanessa; Bermejo-Barrera, Pilar; Moreda-Piñeiro, Antonio
2013-09-27
The combination of reverse phase high performance liquid chromatography (RP-HPLC) with inductively coupled plasma mass spectrometry (ICP-MS) was used for the determination of monoiodotyrosine (MIT) and diiodotyrosine (DIT) in edible seaweed. A sample pre-treatment based on ultrasound assisted enzymatic hydrolysis was optimized for the extraction of these iodinated amino acids. Pancreatin was selected as the most adequate type of enzyme, and parameters affecting the extraction efficiency (pH, temperature, mass of enzyme and extraction time) were evaluated by univariate approaches. In addition, extractable inorganic iodine (iodide) was also quantified by anion exchange high performance liquid chromatography (AE-HPLC) coupled with ICP-MS. The proposed procedure offered limits of detection of 1.1 and 4.3ngg(-1) for MIT and DIT, respectively. Total iodine contents in seaweed, as well as total iodine in enzymatic digests were measured by ICP-MS after microwave assisted alkaline digestion with tetramethylamonium hydroxide (TMAH) for total iodine assessment, and also by treating the pancreatin extracts (extractable total iodine assessment). The optimized procedure was successfully applied to five different types of edible seaweed. The highest total iodine content, and also the highest iodide levels, was found in the brown seaweed Kombu (6646±45μgg(-1)). Regarding iodinated amino acids, Nori (a red seaweed) was by far the one with the highest amount of both species (42±3 and 0.41±0.024μgg(-1) for MIT and DIT, respectively). In general, MIT concentrations were much higher than the amounts of DIT, which suggests that iodine from iodinated proteins in seaweed is most likely bound in the form of MIT residues. Copyright © 2013 Elsevier B.V. All rights reserved.
Lattuati-Derieux, Agnès; Bonnassies-Termes, Sylvette; Lavédrine, Bertrand
2004-02-13
Solid-phase microextraction (SPME) coupled to gas chromatography/mass spectrometry (GC/MS) has been applied to the analysis of volatile organic compounds emitted from a naturally aged groundwood pulp paper originating from an old book in order to access the products produced through the decomposition reactions occurring in paper upon ageing. Two different extraction methods were developed and compared: headspace SPME and contact SPME. The influence of few extraction parameters were tested in order to define the best extraction conditions. An optimised non-destructive contact SPME method was elaborated and allowed the characterisation of more than 50 individual constituents.
Olkowska, Ewa; Polkowska, Żaneta; Namieśnik, Jacek
2013-11-15
A new analytical procedure for the simultaneous determination of individual cationic surfactants (alkyl benzyl dimethyl ammonium chlorides) in surface water samples has been developed. We describe this methodology for the first time: it involves the application of solid phase extraction (SPE-for sample preparation) coupled with ion chromatography-conductivity detection (IC-CD-for the final determination). Mean recoveries of analytes between 79% and 93%, and overall method quantification limits in the range from 0.0018 to 0.038 μg/mL for surface water and CRM samples were achieved. The methodology was applied to the determination of individual alkyl benzyl quaternary ammonium compounds in environmental samples (reservoir water) and enables their presence in such types of waters to be confirmed. In addition, it is a simpler, less time-consuming, labour-intensive, avoiding use of toxic chloroform and significantly less expensive methodology than previously described approaches (liquid-liquid extraction coupled with liquid chromatography-mass spectrometry). Copyright © 2013 Elsevier B.V. All rights reserved.
Multielement extraction system for the determination of 18 trace elements in geochemical samples
Clark, J.R.; Viets, J.G.
1981-01-01
A Methyl isobutyl ketone-Amine synerGistic Iodide Complex (MAGIC) extraction system has been developed for use in geochemical exploration which separates a maximum number of trace elements from interfering matrices. Extraction curves for 18 of these trace elements are presented: Pd, Pt, Cu, Ag, Au, Zn, Cd, Hg, Ga, In, Tl, Sa, Pb, As, Sb, Bi, Se, and Te. The acid normality of the aqueous phase controls the extraction into the organic phase, and each of these 18 elements has a broad range of HCl normality over which H is quantitatively extracted, making H possible to determine all 18 trace elements from a single sample digestion or leach solution. The extract can be analyzed directly by flame atomic absorption or inductively coupled plasma emission spectroscopy. Most of these 18 elements can be determined by Nameless atomic absorption after special treatment of the organic extract.
Hyperpolarized xenon NMR and MRI signal amplification by gas extraction
Zhou, Xin; Graziani, Dominic; Pines, Alexander
2009-01-01
A method is reported for enhancing the sensitivity of NMR of dissolved xenon by detecting the signal after extraction to the gas phase. We demonstrate hyperpolarized xenon signal amplification by gas extraction (Hyper-SAGE) in both NMR spectra and magnetic resonance images with time-of-flight information. Hyper-SAGE takes advantage of a change in physical phase to increase the density of polarized gas in the detection coil. At equilibrium, the concentration of gas-phase xenon is ≈10 times higher than that of the dissolved-phase gas. After extraction the xenon density can be further increased by several orders of magnitude by compression and/or liquefaction. Additionally, being a remote detection technique, the Hyper-SAGE effect is further enhanced in situations where the sample of interest would occupy only a small proportion of the traditional NMR receiver. Coupled with targeted xenon biosensors, Hyper-SAGE offers another path to highly sensitive molecular imaging of specific cell markers by detection of exhaled xenon gas. PMID:19805177
He, Jinxing; Wang, Shuo; Fang, Guozhen; Zhu, Huaping; Zhang, Yan
2008-05-14
A selective imprinted amino-functionalized silica gel sorbent was prepared by combining a surface molecular imprinting technique with a sol-gel process for online solid-phase extraction-HPLC determination of three trace sulfonamides in pork and chicken muscle. The imprinted functionalized silica gel sorbent exhibited selectivity and fast kinetics for the adsorption and desorption of sulfonamides. With a sample loading flow rate of 4 mL min (-1) for 12.5 min, enhancement factors and detection limits for three sulfonamides ( S/ N = 3) were achieved. The precision (RSD) for nine replicate online sorbent extractions of 5 microg L (-1) sulfonamides was less than 4.5%. The sorbent also offered good linearity ( r (2) > 0.99) for online solid-phase extraction of trace levels of sulfonamides. The method was applied to the determination of sulfonamides in pork and chicken muscle samples. The prepared polymer sorbent shows promise for online solid-phase extraction for HPLC determination of trace levels of sulfonamides in pork and chicken samples.
Stravs, Michael A; Mechelke, Jonas; Ferguson, P Lee; Singer, Heinz; Hollender, Juliane
2016-03-01
Online solid-phase extraction was combined with nano-liquid chromatography coupled to high-resolution mass spectrometry (HRMS) for the analysis of micropollutants in environmental samples from small volumes. The method was validated in surface water, Microcystis aeruginosa cell lysate, and spent Microcystis growth medium. For 41 analytes, quantification limits of 0.1-28 ng/L (surface water) and 0.1-32 ng/L (growth medium) were obtained from only 88 μL of sample. In cell lysate, quantification limits ranged from 0.1-143 ng/L or 0.33-476 ng/g dry weight from a sample of 88 μL, or 26 μg dry weight, respectively. The method matches the sensitivity of established online and offline solid-phase extraction-liquid chromatography-mass spectrometry methods but requires only a fraction of the sample used by those techniques, and is among the first applications of nano-LC-MS for environmental analysis. The method was applied to the determination of bioconcentration in Microcystis aeruginosa in a laboratory experiment, and the benefit of coupling to HRMS was demonstrated in a transformation product screening.
Bellon, L; Maloney, L; Zinnen, S P; Sandberg, J A; Johnson, K E
2000-08-01
Versatile bioanalytical assays to detect chemically stabilized hammerhead ribozyme and putative ribozyme metabolites from plasma are described. The extraction protocols presented are based on serial solid-phase extractions performed on a 96-well plate format and are compatible with either IEX-HPLC or CGE back-end analysis. A validation of both assays confirmed that both the HPLC and the CGE methods possess the required linearity, accuracy, and precision to accurately measure concentrations of hammerhead ribozyme extracted from plasma. These methods should be of general use to detect and quantitate ribozymes from other biological fluids such as serum and urine. Copyright 2000 Academic Press.
Schulz, H; Albroscheit, G
1988-06-17
Rapid and reliable methods are presented for the characterization of biologically active and/or characteristic constituents in aqueous extracts of Hamamelis virginiana, Matricaria chamomilla, Achillea millefolium, Thymus vulgaris, Althaea officinalis and Cinchonia spp. Prior to high-performance liquid chromatographic (HPLC) separation a clean-up step was performed using a solid-phase extraction system. The purified extracts were analysed by HPLC coupled with a diode-array detector and a fluorescence detector. In some instances, previously unreported components of the aqueous plant extracts were found.
Organic compounds in radiation fogs in Davis (California)
NASA Astrophysics Data System (ADS)
Herckes, Pierre; Hannigan, Michael P.; Trenary, Laurie; Lee, Taehyoung; Collett, Jeffrey L.
New stainless steel active fogwater collectors were designed and used in Davis (CA, USA) to collect fogwater for the speciation of organic matter. Organic compounds in fog samples were extracted by liquid-liquid extraction and analyzed by gas chromatography coupled to mass spectrometry. Numerous organic compounds, including various alkanes, polycyclic aromatic hydrocarbons (PAH) and alkanoic acids, have been identified in the fogwater samples. Higher molecular weight (MW) compounds are preferentially associated with an insoluble phase inside the fog drops, whereas lower molecular weight and more polar compounds are found predominantly in the dissolved phase. Concentrations in the dissolved phase were sometimes much higher than estimated by the compounds' aqueous solubilities.
Moloney, M; Tuck, S; Ramkumar, A; Furey, A; Danaher, M
2018-03-01
A method was developed for the confirmatory and quantitative analysis of one pyrethrin and 18 pyrethroid residues in animal fat. Fat was extracted was collected from adipose tissue melted in an oven at 65 °C for 2 h. Fat samples (1 g) were dispersed with deactivated Florisil ® sorbent and extracted with MeCN. Sample extracts were purified by cold temperature precipitation at -30 °C for 4 h and further purified using dispersive solid-phase extraction (d-SPE) clean-up in tubes containing 500 mg of Z-SEP+ and 125 mg of PSA bonded silica. Purified samples were analysed by ultra-high performance liquid chromatography coupled to tandem mass spectrometry (UHPLC-MS/MS) detection. Chromatographic separation was carried out on a Acquity C 8 BEH column, using a binary gradient separation comprising of mobile phase A, 5 mM ammonium formate in water:MeOH (80:20, v/v,) and mobile phase B, 5 mM ammonium formate in MeOH. The mass spectrometer was operated in the positive electrospray ionisation mode (ESI(+)). Validation was performed following the 2002/657/EC guidelines. Trueness ranged between 84% and 143% and precision ranged between 3.9% and 29%. The developed method is particularly advantageous because the sample preparation procedure does not require complex sample extraction equipment and uses less solvent compared to other sample preparation protocols. Copyright © 2017 Elsevier B.V. All rights reserved.
Jiang, Yuehuang; Tang, Tingting; Cao, Zhen; Shi, Guoyue; Zhou, Tianshu
2015-06-01
A hydroxyl-functionalized ionic liquid, 1-hydroxyethyl-3-methylimidazolium bis(trifluoromethanesulfonyl)imide, was employed in an improved dispersive liquid-phase microextraction method coupled with ultra high performance liquid chromatography for the enrichment and determination of three estrogens and bisphenol A in environmental water samples. The introduced hydroxyl group acted as the H-bond acceptor that dispersed the ionic liquid effectively in the aqueous phase without dispersive solvent or external force. Fourier transform infrared spectroscopy indicated that the hydroxyl group of the cation of the ionic liquid enhanced the combination of extractant and analytes through the formation of hydrogen bonds. The improvement of the extraction efficiency compared with that with the use of alkyl ionic liquid was proved by a comparison study. The main parameters including volume of extractant, temperature, pH, and extraction time were investigated. The calibration curves were linear in the range of 5.0-1000 μg/L for estrone, estradiol, and bisphenol A, and 10.0-1000 μg/L for estriol. The detection limits were in the range of 1.7-3.4 μg/L. The extraction efficiency was evaluated by enrichment factor that were between 85 and 129. The proposed method was proved to be simple, low cost, and environmentally friendly for the determination of the four endocrine disruptors in environmental water samples. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Rahman, Md Musfiqur; Abd El-Aty, A M; Kim, Sung-Woo; Shin, Sung Chul; Shin, Ho-Chul; Shim, Jae-Han
2017-01-01
In pesticide residue analysis, relatively low-sensitivity traditional detectors, such as UV, diode array, electron-capture, flame photometric, and nitrogen-phosphorus detectors, have been used following classical sample preparation (liquid-liquid extraction and open glass column cleanup); however, the extraction method is laborious, time-consuming, and requires large volumes of toxic organic solvents. A quick, easy, cheap, effective, rugged, and safe method was introduced in 2003 and coupled with selective and sensitive mass detectors to overcome the aforementioned drawbacks. Compared to traditional detectors, mass spectrometers are still far more expensive and not available in most modestly equipped laboratories, owing to maintenance and cost-related issues. Even available, traditional detectors are still being used for analysis of residues in agricultural commodities. It is widely known that the quick, easy, cheap, effective, rugged, and safe method is incompatible with conventional detectors owing to matrix complexity and low sensitivity. Therefore, modifications using column/cartridge-based solid-phase extraction instead of dispersive solid-phase extraction for cleanup have been applied in most cases to compensate and enable the adaptation of the extraction method to conventional detectors. In gas chromatography, the matrix enhancement effect of some analytes has been observed, which lowers the limit of detection and, therefore, enables gas chromatography to be compatible with the quick, easy, cheap, effective, rugged, and safe extraction method. For liquid chromatography with a UV detector, a combination of column/cartridge-based solid-phase extraction and dispersive solid-phase extraction was found to reduce the matrix interference and increase the sensitivity. A suitable double-layer column/cartridge-based solid-phase extraction might be the perfect solution, instead of a time-consuming combination of column/cartridge-based solid-phase extraction and dispersive solid-phase extraction. Therefore, replacing dispersive solid-phase extraction with column/cartridge-based solid-phase extraction in the cleanup step can make the quick, easy, cheap, effective, rugged, and safe extraction method compatible with traditional detectors for more sensitive, effective, and green analysis. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Serra-Mora, P; Jornet-Martinez, N; Moliner-Martinez, Y; Campíns-Falcó, P
2017-09-01
In-tube solid-phase microextraction (IT-SPME) coupled to miniaturized liquid chromatography (LC) techniques are attractive mainly due to the column efficiency improvement, sensitivity enhancement and reduction of solvent consumption. In addition, the nanomaterials based sorbents can play a key role in the improvement of the extraction efficiency taking into account their interesting physical and chemical properties. Thus, in this work the performance of IT-SPME coupled to nano LC (NanoLC) has been compared with the performance of IT-SPME coupled to capillary LC (CapLC) with similar configurations for the determination of polar triazines including their degradation products. In both cases, a DAD detector was used. Different extractive phases such as TRB-5, TRB-5/c-SWNTs, TRB-5/c-MWNTs capillary columns have been tested. The dimensions of the capillary columns were 0.32mm id×40cm length and 0.1 or 0.075mm i.d.×15cm length for the couplings with CapLC and NanoLC, respectively. The processed volume was 4mL for CapLC and 0.5mL for NanoLC. The elution was carried out with ACN:H 2 O (30:70, v/v). IT-SPME-NanoLC has shown a higher performance than IT-SPME-CapLC for the target analytes demonstrating the enhancement of the extraction efficiency with the former configuration. A new phase TEOS-MTEOS-SiO 2 NPs has been also proposed for IT-SPME-NanoLC, which improves the retention of polar compounds. Compared with previously published works, improved LODs were achieved (0.025-0.5μgL -1 ). The practical application of the proposed procedure has been demonstrated for the analysis of water samples and recovered struvite samples from wastewater treatment plants. Therefore, the proposed procedure can be an alternative method for regulatory purposes. Copyright © 2017 Elsevier B.V. All rights reserved.
López Monzón, A; Vega Moreno, D; Torres Padrón, M E; Sosa Ferrera, Z; Santana Rodríguez, J J
2007-03-01
Solid-phase microextraction (SPME) coupled with high-performance liquid chromatography (HPLC) with fluorescence detection was optimized for extraction and determination of four benzimidazole fungicides (benomyl, carbendazim, thiabendazole, and fuberidazole) in water. We studied extraction and desorption conditions, for example fiber type, extraction time, ionic strength, extraction temperature, and desorption time to achieve the maximum efficiency in the extraction. Results indicate that SPME using a Carboxen-polydimethylsiloxane 75 microm (CAR-PDMS) fiber is suitable for extraction of these types of compound. Final analysis of benzimidazole fungicides was performed by HPLC with fluorescence detection. Recoveries ranged from 80.6 to 119.6 with RSDs below 9% and limits of detection between 0.03 and 1.30 ng mL-1 for the different analytes. The optimized procedure was applied successfully to the determination of benzimidazole fungicides mixtures in environmental water samples (sea, sewage, and ground water).
Coupled intertwiner dynamics: A toy model for coupling matter to spin foam models
NASA Astrophysics Data System (ADS)
Steinhaus, Sebastian
2015-09-01
The universal coupling of matter and gravity is one of the most important features of general relativity. In quantum gravity, in particular spin foams, matter couplings have been defined in the past, yet the mutual dynamics, in particular if matter and gravity are strongly coupled, are hardly explored, which is related to the definition of both matter and gravitational degrees of freedom on the discretization. However, extracting these mutual dynamics is crucial in testing the viability of the spin foam approach and also establishing connections to other discrete approaches such as lattice gauge theories. Therefore, we introduce a simple two-dimensional toy model for Yang-Mills coupled to spin foams, namely an Ising model coupled to so-called intertwiner models defined for SU (2 )k. The two systems are coupled by choosing the Ising coupling constant to depend on spin labels of the background, as these are interpreted as the edge lengths of the discretization. We coarse grain this toy model via tensor network renormalization and uncover an interesting dynamics: the Ising phase transition temperature turns out to be sensitive to the background configurations and conversely, the Ising model can induce phase transitions in the background. Moreover, we observe a strong coupling of both systems if close to both phase transitions.
Kertesz, Vilmos; Van Berkel, Gary J
2010-07-15
In this work, a commercially available autosampler was adapted to perform direct liquid microjunction (LMJ) surface sampling followed by a high-pressure liquid chromatography (HPLC) separation of the extract components and detection with electrospray ionization mass spectrometry (ESI-MS). To illustrate the utility of coupling a separation with this direct liquid extraction based surface sampling approach, four different organs (brain, lung, kidney, and liver) from whole-body thin tissue sections of propranolol dosed and control mice were examined. The parent drug was observed in the chromatograms of the surface sampling extracts from all the organs of the dosed mouse examined. In addition, two isomeric phase II metabolites of propranolol (an aliphatic and an aromatic hydroxypropranolol glucuronide) were observed in the chromatograms of the extracts from lung, kidney, and liver. Confirming the presence of one or the other or both of these glucuronides in the extract from the various organs was not possible without the separation. These drug and metabolite data obtained using the LMJ surface sampling/HPLC-MS method and the results achieved by analyzing similar samples by conventional extraction of the tissues and subsequent HPLC-MS analysis were consistent. The ability to directly and efficiently sample from thin tissue sections via a liquid extraction and then perform a subsequent liquid phase separation increases the utility of this liquid extraction surface sampling approach.
Peng, Xiaojun; Pang, Jinshan; Deng, Aihua
2011-12-01
A novel method for the simultaneous determination of seven phenoxyacid herbicides such as dicamba, fluroxypyr, 4-chlorophenoxyacetic acid (4-CPA), 2-methyl-4-chlorophenoxyacetic acid (MCPA), 2, 4-dichlorophenoxyacetic acid (2,4-D), 2,4-dichlorophenoxybutyric acid (2,4-DB) and 4-(2-methyl-4-chlorophenoxy) butyric acid (MCPB) in environmental water by three phase hollow fiber liquid phase microextraction (HF-LPME) coupled with high performance liquid chromatography (HPLC) was developed. In order to optimize the experimental conditions, the orthogonal test has been used. The effects of extraction solvent, pH of the donor phase and acceptor phase, extraction time, stirring speed and salt concentration on the detection were investigated. The optimal experimental conditions were as follows: octanol as organic solvent, pH 3 of donor phase, pH 12 of acceptor phase, extraction time of 30 min, stirring speed of 400 r/min. The results showed that the proposed method provided a wide linear range for 7 phenoxyacid herbicides with correlation coefficients of 0.995 3 - 0.998 8. The detection limits ranged from 0.2 to 1.0 microg/L. The enrichment factors were in the range of 76.7 - 121. The recoveries were in the range of 68% - 104% and the relative standard deviations (RSDs) were less than 8.1% for the environmental water samples. The method has the advantages of sensitivity, simplicity, fastness and the use of very small amounts of organic solvent. The method can meet the requirements of the determination of trace phenoxyacid herbicides in the environmental water samples, and the study provided a useful method for the analysis of trace substances in water samples.
Háková, Martina; Chocholoušová Havlíková, Lucie; Chvojka, Jiří; Solich, Petr; Šatínský, Dalibor
2018-02-01
Polyamide 6 nanofiber polymers were used as modern sorbents for on-line solid phase extraction (SPE) coupled with liquid chromatography. The on-line SPE system was tested for the determination of bisphenol A in river water samples. Polyamide nanofibers were prepared using needleless electrospinning, inserted into a mini-column cartridge (5 × 4.6mm) and coupled with HPLC. The effect of column packing and the amount of polyamide 6 on extraction efficiency was tested and the packing process was optimized. The proposed method was performed using a 50-µL sample injection followed by an on-line nanofibrous extraction procedure. The influence of the washing mobile phase on the retention of bisphenol A during the extraction procedure was evaluated. Ascentis ® Express C18 (10cm × 4.6mm) core-shell column was used as an analytical column. Fluorescence detection wavelengths (λ ex = 225nm and λ em = 320nm) were used for identification and quantification of Bisphenol A in river waters. The linearity was tested in the range from 2 to 500µgL -1 (using nine calibration points). The limits of detection and quantification were 0.6 and 2µgL -1 , respectively. The developed method was successfully used for the determination of bisphenol A in various samples of river waters in the Czech Republic (The Ohře, Labe, Nisa, Úpa, and Opava Rivers). Copyright © 2017 Elsevier B.V. All rights reserved.
Ye, Diru; Wu, Susu; Xu, Jianqiao; Jiang, Ruifen; Zhu, Fang; Ouyang, Gangfeng
2016-02-01
Direct immersion solid-phase microextraction (DI-SPME) coupled with gas chromatography-mass spectrometry (GC-MS) was developed for rapid analysis of clenbuterol in pork for the first time. In this work, a low-cost homemade 44 µm polydimethylsiloxane (PDMS) SPME fiber was employed to extract clenbuterol in pork. After extraction, derivatization was performed by suspending the fiber in the headspace of the 2 mL sample vial saturated with a vapor of 100 µL hexamethyldisilazane. Lastly, the fiber was directly introduced to GC-MS for analysis. All parameters that influenced absorption (extraction time), derivatization (derivatization reagent, time and temperature) and desorption (desorption time) were optimized. Under optimized conditions, the method offered a wide linear range (10-1000 ng g(-1)) and a low detection limit (3.6 ng g(-1)). Finally, the method was successfully applied in the analysis of pork from the market, and recoveries of the method for spiked pork were 97.4-105.7%. Compared with the traditional solvent extraction method, the proposed method was much cheaper and fast. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Zhong, Zhixiong; Li, Gongke; Wu, Rong; Zhu, Binghui; Luo, Zhibin
2014-08-01
A simple and reliable ultrasound-assisted solid-phase dispersion extraction coupled with ion chromatography was developed for the determination of aminophenols and phenol. The highly viscous hair colorant was dispersed in solvents using anhydrous sodium sulfite having dual functions of dispersant and antioxidant. The use of anhydrous sodium sulfite did not change the sample volume because it could completely dissolve in solution after matrix dispersion. The extraction and cleanup were combined in one single step for simplifying operation. The extraction process could be rapidly accomplished within 9 min with high sample throughput under the synergistic effects of vibration, ultrasound, and heating. Satisfactory linearity was observed with correlation coefficients higher than 0.9992, and the limits of detection varied from 0.02 to 0.09 mg/L. The applicability of the proposed method was demonstrated by measuring the concentrations of aminophenols and phenol in 32 different commercial hair color products. The recoveries ranged from 86.4-101.2% with the relative standard deviations in the range of 0.52-4.3%. The method offers an attractive alternative for the analysis of trace phenols in complex matrices. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Hu, Xiaogang; Hu, Yuling; Li, Gongke
2007-04-13
A novel molecularly imprinted polymer (MIP) coated solid-phase microextraction (SPME) fiber that could be coupled directly to high-performance liquid chromatography (HPLC) was prepared with prometryn as the template molecule. The characteristics and application of this fiber were investigated. Electron microscope photographs indicated that the MIP coating with average thickness of 25.0 microm was homogeneous and porous. The extraction yield of prometryn with the MIP-coated fibers was 10 times as much as that with the non-imprinted polymer (NIP) coated fibers. And special selectivity to other triazines which have similar structure to prometryn was discovered with the MIP-coated fibers. A method for the determination of triazines by the MIP-coated SPME coupled with HPLC was developed. The optimized extraction conditions were studied. Detection limits for the triazines studied were within the range of 0.012-0.090 microg/L. The method was applied to five triazines determination in the spiked soybean, corn, lettuce, and soil samples with the recoveries of 78.0-103.5%, 82.4-113.4%, 75.5-83.4%, and 81.0-106.1%, respectively. The MIP-coated fibers are suitable for the selective extraction of trace triazines in complicated samples.
1988-10-26
concentrated into this off- axis peak is then considered. Estimates of the source brightness ( extraction ion diode source current density divided by the square...radioactive contamination of the accelerator. One possible scheme for avoiding this problem is to use extraction geometry ion diodes to focus the ion beams...annular region. These results will be coupled to two simple models of extraction ion diodes to determihe the ion source brightness requirements. These
Borrás Linares, I; Arráez-Román, D; Herrero, M; Ibáñez, E; Segura-Carretero, A; Fernández-Gutiérrez, A
2011-10-21
In the present work, a comparative study between two environmentally friendly and selective extraction techniques, such as supercritical fluid extraction (SFE) and pressurized liquid extraction (PLE) have been carried out focusing in the bioactive phenolic compounds present in Rosmarinus officinalis. For the analysis of the SFE and PLE extracts, a new methodology for qualitative characterization has been developed, based on the use of reversed-phase high-performance liquid chromatography (RP-HPLC), equipped with two different detection systems coupled in series: diode array detector (DAD) and time of flight mass spectrometry (TOF-MS) detector connected via an electrospray ionization interface (ESI). The use of a small particle size C(18) column (1.8 μm) provided a great resolution and made possible the separation of several isomers. Moreover, UV-visible spectrophotometry is a valuable tool for identifying the class of phenolic compounds, whereas MS data enabled to structurally characterize the compounds present in the extracts. The applied methodology was useful for the determination of many well-known phenolic compounds present in R. officinalis, such as carnosol, carnosic acid, rosmadial, rosmanol, genkwanin, homoplantaginin, scutellarein, cirsimaritin and rosmarinic acid, as well as other phenolic compounds present in other species belonging to Lamiaceae family. Copyright © 2011 Elsevier B.V. All rights reserved.
Ruan, Can-Jun; Guo, Wei; Zhou, Miao; Guo, Gui-Xin; Wang, Chuan-Yue; Li, Wen-Biao; de Leon, Jose
2018-07-01
A recent guideline recommends therapeutic drug monitoring for risperidone, paliperidone and olanzapine, which are frequently used second-generation antipsychotics. We developed a simple high-performance liquid chromatography-tandem mass spectrometry coupled with an online solid-phase extraction method that can be used to measure risperidone, paliperidone and olanzapine using small (40 μL) samples. The analytes were extracted from serum samples automatically pre-concentrated and purified by C 8 (5 μm, 2.1 × 30 mm) solid-phase extraction cartridges, then chromatographed on an Xbidge™ C 18 column (3.5 μm, 100 × 2.1 mm) thermostatted at 30°C with a mobile phase consisting of 70% acetonitrile and 30% ammonium hydroxide 1% solution at an isocratic flow rate of 0.3 mL/min, and detected with tandem mass spectrometry. The assay was validated in the concentration range from 2.5 to 160 ng/mL. Intra- and inter-day precision for all analytes was between 1.1 and 8.2%; method accuracy was between 6.6 and 7.6%. The risperidone and paliperidone assay was compared with a high-performance liquid chromatography-ultraviolet assay currently used in our hospital for risperidone and paliperidone therapeutic drug monitoring, and the results of weighted Deming regression analysis showed good agreement. For the olanzapine assay, we compared 20 samples in separate re-assays on different days; all the relative errors were within the 20% recommended limit. Copyright © 2018 John Wiley & Sons, Ltd.
Leite, Tonny Cley Campos; de Sena, Amanda Reges; Dos Santos Silva, Tânia Regina; Dos Santos, Andrea Karla Almeida; Uetanabaro, Ana Paula Trovatti; Branco, Alexsandro
2012-07-01
Marcetia genera currently comprises 29 species, with approximately 90% inhabiting Bahia (Brazil), and most are endemic to the highlands of the Chapada Diamantina (Bahia). Among the species, only M. taxifolia (A.St.-Hil.) DC. populates Brazil (state of Roraima to Paraná) and also Venezuela, Colombia, and Guyana. This work evaluated the antimicrobial activity of hexane, ethyl acetate, and methanol extracts of three species of Marcetia (Marcetia canescens Naud., M. macrophylla Wurdack, and M. taxifolia A.StHil) against several microorganism. In addition, the flavonoids were analyzed in extracts by HPLC-DAD. The tests were made using Gram-positive (three strains of Staphylococcus aureus) and Gram-negative (two strains of Escherichia coli, a strain of Pseudomonas aeruginosa and another of Salmonella choleraesius) bacteria resistant and nonresistant to antibiotics and yeasts (two strains of Candida albicans and one of C. parapsilosis) by the disk diffusion method. Solid-phase extraction (SPE) was performed on the above extracts to isolate flavonoids, which were subsequently analyzed by high performance liquid chromatography coupled diode array detector (HPLC-DAD). Results showed that extracts inhibited the Gram-positive bacteria and yeast. The hexane extracts possessed the lowest activity, while the ethyl acetate and methanolic extracts were more active. Marcetia taxifolia was more effective (active against 10 microorganisms studied), and only its methanol extract inhibited Gram-negative bacteria (P. aeruginosa and S. choleraesius). SPE and HPLC-DAD analysis showed that M. canescens and M. macrophylla contain glycosylated flavonoids, while the majority of extracts from M. taxifolia were aglycone flavonoids.
Felhofer, Jessica L.; Scida, Karen; Penick, Mark; Willis, Peter A.; Garcia, Carlos D.
2013-01-01
To overcome the problem of poor sensitivity of capillary electrophoresis-UV absorbance for the detection of aliphatic amines, a solid phase extraction and derivatization scheme was developed. This work demonstrates successful coupling of amines to a chromophore immobilized on a solid phase and subsequent cleavage and analysis. Although the analysis of many types of amines is relevant for myriad applications, this paper focuses on the derivatization and separation of amines with environmental relevance. This work aims to provide the foundations for future developments of an integrated sample preparation microreactor capable of performing simultaneous derivatization, preconcentration, and sample cleanup for sensitive analysis of primary amines. PMID:24054648
Sha, Ou; Zhu, Xiashi; Feng, Yanli; Ma, Weixing
2015-05-01
A rapid and effective method of aqueous two-phase systems based on ionic liquid microextraction for the simultaneous determination of five synthetic food colourants (tartrazine, sunset yellow, amaranth, ponceau 4R and brilliant blue) in food samples was established. High-performance liquid chromatography coupled with an ultraviolet detector of variable wavelength was used for the determinations. 1-alkyl-3-methylimidazolium bromide was selected as the extraction reagent. The extraction efficiency of the five colourants in the proposed system is influenced by the types of salts, concentrations of salt and [CnMIM]Br, as well as the extracting time. Under the optimal conditions, the extraction efficiencies for these five colourants were above 95%. The phase behaviours of aqueous two-phase system and extraction mechanism were investigated by UV-vis spectroscopy. This method was applied to the analysis of the five colourants in real food samples with the detection limit of 0.051-0.074 ng/mL. Good spiked recoveries from 93.2% to 98.9% were obtained. Copyright © 2014 Elsevier Ltd. All rights reserved.
Chen, Hsin-Chang; Ding, Wang-Hsien
2006-03-10
A comprehensive method for the determination of four stilbene-type disulfonate and one distyrylbiphenyl-type fluorescent whitening agents (FWAs) in paper materials (napkin and paper tissue) and infant clothes was developed. FWAs were extracted from paper material and cloth samples using a hot-water extraction, and the aqueous extracts were then preconcentrated with the newly developed Oasis WAX (mixed-mode of weak anion exchange and reversed-phase sorbent) solid-phase extraction cartridge. The analytes were unequivocal determined by ion pair chromatography coupled with negative electrospray ionization-tandem mass spectrometry (HPLC-ESI-MS-MS), applying a di-n-hexyl-ammonium acetate (DHAA) as the ion-pairing reagent in mobile phase. Limits of quantitation (LOQ) were established between 0.2 and 0.9 ng/g in 2 g of samples. Recovery of five FWAs in spiked commercial samples was between 42 and 95% and RSD (n = 3) ranging from 2 to 11%. The method was finally applied to commercial samples, showing that two stilbene-type disulfonates were predominant FWAs detected in napkin and infant cloth samples.
Zhou, Caihong; Tong, Shanshan; Chang, Yunxia; Jia, Qiong; Zhou, Weihong
2012-04-01
Ionic liquid (IL) based dispersive liquid-liquid microextraction (DLLME) with back-extraction coupled with capillary electrophoresis ultraviolet detection was developed to determine four phenolic compounds (bisphenol-A, β-naphthol, α-naphthol, 2, 4-dichlorophenol) in aqueous cosmetics. The developed method was used to preconcentrate and clean up the four phenolic compounds including two steps. The analytes were transferred into room temperature ionic liquid (1-octyl-3-methylimidazolium hexafluorophosphate, [C(8) MIM][PF(6) ]) rich-phase in the first step. In the second step, the analytes were back-extracted into the alkaline aqueous phase. The effects of extraction parameters, such as type and volume of extraction solvent, type and volume of disperser, extraction and centrifugal time, sample pH, salt addition, and concentration and volume of NaOH in back-extraction were investigated. Under the optimal experimental conditions, the preconcentration factors were 60.1 for bisphenol-A, 52.7 for β-naphthol, 49.2 for α-naphthol, and 18.0 for 2, 4-dichlorophenol. The limits of detection for bisphenol-A, β-naphthol, α-naphthol and 2, 4-dichlorophenol were 5, 5, 8, and 100 ng mL(-1), respectively. Four kinds of aqueous cosmetics including toner, soften lotion, make-up remover, and perfume were analyzed and yielded recoveries ranging from 81.6% to 119.4%. The main advantages of the proposed method are quick, easy, cheap, and effective. © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Lhotská, Ivona; Holznerová, Anežka; Solich, Petr; Šatínský, Dalibor
2017-12-01
Reaching trace amounts of mycotoxin contamination requires sensitive and selective analytical tools for their determination. Improving the selectivity of sample pretreatment steps covering new and modern extraction techniques is one way to achieve it. Molecularly imprinted polymers as selective sorbent for extraction undoubtedly meet these criteria. The presented work is focused on the hyphenation of on-line molecularly imprinted solid-phase extraction with a chromatography system using a column-switching approach. Making a critical comparison with a simultaneously developed off-line extraction procedure, evaluation of pros and cons of each method, and determining the reliability of both methods on a real sample analysis were carried out. Both high-performance liquid chromatography methods, using off-line extraction on molecularly imprinted polymer and an on-line column-switching approach, were validated, and the validation results were compared against each other. Although automation leads to significant time savings, fewer human errors, and required no handling of toxic solvents, it reached worse detection limits (15 versus 6 μg/L), worse recovery values (68.3-123.5 versus 81.2-109.9%), and worse efficiency throughout the entire clean-up process in comparison with the off-line extraction method. The difficulties encountered, the compromises made during the optimization of on-line coupling and their critical evaluation are presented in detail. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Burkhardt, M.R.; ReVello, R.C.; Smith, S.G.; Zaugg, S.D.
2005-01-01
A broad range of organic compounds is recognized as environmentally relevant for their potential adverse effects on human and ecosystem health. This method was developed to better determine the distribution of 61 compounds that are typically associated with industrial and household waste as well as some that are toxic and known (or suspected) for endocrine-disrupting potential extracted from environmental sediment samples. Pressurized liquid extraction (PLE) coupled with solid-phase extraction (SPE) was used to reduce sample preparation time, reduce solvent consumption to one-fifth of that required using dichloromethane-based Soxhlet extraction, and to minimize background interferences for full scan GC/MS analysis. Recoveries from spiked Ottawa sand, commercially available topsoil, and environmental stream sediment, fortified at 4-720 ??g per compound, averaged 76 ?? 13%. Initial method detection limits for single-component compounds ranged from 12.5 to 520 ??g/kg, based on 25 g samples. Results from 103 environmental sediment samples show that 36 out of 61 compounds (59%) were detected in at least one sample with concentrations ranging from 20 to 100,000 ??g/kg. The most frequently detected compound, beta-sitosterol, a plant sterol, was detected in 87 of the 103 (84.5%) environmental samples with a concentration range 360-100,000 ??g/kg. Results for a standard reference material using dichloromethane Soxhlet-based extraction are also compared. ?? 2004 Published by Elsevier B.V.
Xie, Juan-ping; Xiang, Ji-ming; Zhu, Zhong-liang
2016-01-01
A simple, accurate and reproducible method which is based on the capillary electrophoresis, coupled with solid-phase extraction, has been developed for simultaneous determination of multiple 8-prenylflavones from Chinese Herba Epimedii. In this study, the author has mainly illustrated the experimental process and research results of five major components including epimedin C, icariin, diphylloside A, epimedoside A and icarisoside A that have been extracted and identified from Herba Epimedii for the first time. Experimental conditions have been optimized to achieve the best separation efficiency for the following factors: the buffer pH, buffer concentration and applied voltage. The experiment can be conducted through two separable stages: the first stage is to obtain the crude extracts through the solid-phase extraction; and the second stage is to further separate five major components by using the capillary electrophoresis. The separation of the five components and the analysis of the experiment are relatively fast and can be completed within 20 min. The concentration ranges of the construction of standard curves of five major 8-prenylflavones are 32.0–395.0, 23.4–292.0, 42.1–526.0, 18.8–233.5 and 29.7–371.0 µg mL−1 respectively, which have showed acceptable linearity with a correlation coefficient, r ≥ 0.999. The coefficient varies within 2.0% for both intra- and inter-days tests. The recoveries of five components range from 92.3 to 104.1%. The relative standard deviations of recoveries of five components range from 1.2 and 2.8%. This new method will facilitate the extraction and expedite the determination of medical components from Herba Epimedii. PMID:26865656
Zeng, Qiong; Liu, Yi-Ming; Jia, Yan-Wei; Wan, Li-Hong; Liao, Xun
2017-02-01
Carbon nanotubes (CNTs) possess large potential as extraction absorbents in solid phase extraction. They have been widely applied in biomedicine research, while very rare application in natural product chemistry has been reported. In this work, methoxypolyethylene glycol amine (mPEG-NH 2 ) is covalently coupled to CNTs-magnetic nanoparticles (CNTs-MNP) to prepare a novel magnetic nanocomposite (PEG-CNTs-MNP) for use as dispersive solid-phase extraction (DSPE) absorbent. The average particle size was 86nm, and the saturation magnetization was 52.30emu/g. This nanocomposite exhibits excellent dispersibility in aqueous systems, high selectivity and fast binding kinetics when used for extraction of Z-ligustilide, the characteristic bioactive compound from two popular Asian herbal plants, R. chuanxiong and R. ligusticum. HPLC quantification of Z-ligustilide extracted from the standard sample solution showed a high recovery of 98.9%, and the extraction rate from the extracts of the above two herbs are both around 70.0%. To our knowledge, this is the first report on using PEG-CNTs-MNP as DSPE nanosorbents for selective extraction of natural products. This nano-material has promising application in isolation and enrichment of targeted components from complex matrices. Copyright © 2016 Elsevier B.V. All rights reserved.
Li, Na; Wu, Lijie; Nian, Li; Song, Ying; Lei, Lei; Yang, Xiao; Wang, Kun; Wang, Zhibing; Zhang, Liyuan; Zhang, Hanqi; Yu, Aimin; Zhang, Ziwei
2015-09-01
Non-polar solvent dynamic microwave assisted extraction was firstly applied to the treatment of high-fat soybean samples. In the dispersive micro-solid-phase extraction (D-µ-SPE), the herbicides in the high-fat extract were directly adsorbed on metal-organic frameworks MIL-101(Cr). The effects of several experimental parameters, including extraction solvent, microwave absorption medium, microwave power, volume and flow rate of extraction solvent, amount of MIL-101(Cr), and D-µ-SPE time, were investigated. At the optimal conditions, the limits of detection for the herbicides ranged from 1.56 to 2.00 μg kg(-1). The relative recoveries of the herbicides were in the range of 91.1-106.7%, and relative standard deviations were equal to or lower than 6.7%. The present method was simple, rapid and effective. A large amount of fat was also removed. This method was demonstrated to be suitable for treatment of high-fat samples. Copyright © 2015 Elsevier B.V. All rights reserved.
Sheu, Hong-Li; Sung, Yu-Hsiang; Melwanki, Mahaveer B; Huang, Shang-Da
2006-11-01
Solid-phase microextraction (SPME) coupled to LC for the analysis of five diphenylether herbicides (aclonifen, bifenox, fluoroglycofen-ethyl, oxyfluorfen, and lactofen) is described. Various parameters of extraction of analytes onto the fiber (such as type of fiber, extraction time and temperature, pH, impact of salt and organic solute) and desorption from the fiber in the desorption chamber prior to separation (such as type and composition of desorption solvent, desorption mode, soaking time, and flush-out time) were studied and optimized. Four commercially available SPME fibers were studied. PDMS/divinylbenzene (PDMS/DVB, 60 microm) and carbowax/ templated resin (CW/TPR, 50 microm) fibers were selected due to better extraction efficiencies. Repeatability (RSD, < 7%), correlation coefficient (> 0.994), and detection limit (0.33-1.74 and 0.22-1.94 ng/mL, respectively, for PDMS/DVB and CW/TPR) were investigated. Relative recovery (81-104% for PDMS/DVB and 83-100% for CW/TPR fiber) values have also been calculated. The developed method was successfully applied to the analysis of river water and water collected from a vegetable garden.
Constraints on the phase gamma and new physics from B --> kpi decays
He; Hsueh; Shi
2000-01-03
Recent results from CLEO on B-->Kpi indicate that the phase gamma may be substantially different from that obtained from other fit to the KM matrix elements in the standard model. We show that gamma extracted using B-->Kpi,pipi is sensitive to new physics occurring at loop level. It provides a powerful method to probe new physics in electroweak penguin interactions. Using effects due to anomalous gauge couplings as an example, we show that within the allowed ranges for these couplings information about gamma obtained from B-->Kpi,pipi can be very different from the standard model prediction.
Two-phase electromembrane extraction followed by gas chromatography-mass spectrometry analysis.
Davarani, Saied Saeed Hosseiny; Morteza-Najarian, Amin; Nojavan, Saeed; Pourahadi, Ahmad; Abbassi, Mojtaba Beigzadeh
2013-02-01
A two-phase electromembrane extraction (EME) was developed and directly coupled with gas chromatography mass spectrometry (GC-MS) analysis. The proposed method was successfully applied to the simultaneous determination of imipramine, desipramine, citalopram and sertraline. The model compounds were extracted from neutral aqueous sample solutions into the organic phase filled in the lumen of the hollow fiber. This method was accomplished with 1-heptanol as organic phase, by means of 60 V applied voltage and with the extraction time of 15 min. Experiments reported recoveries in the range of 69-87% from 1.2 mL neutral sample solution. The compounds were quantified by GC-MS instrument, with acceptable linearity ranging from 1 to 500 ng mL(-1) (R(2) in the range of 0.989 to 0.998), and repeatability (RSD) ranging between 7.5 and 11.5% (n = 5). The estimated detection limits (S/N ratio of 3:1) were less than 0.25 ng mL(-1). This novel approach based on two-phase EME brought advantages such as simplicity, low-costing, low detection limit and fast extraction with a total analysis time less than 25 min. These experimental findings were highly interesting and demonstrated the possibility of solving ionic species in the organic phase at the presence of electrical potential. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Campone, Luca; Piccinelli, Anna Lisa; Celano, Rita; Pagano, Imma; Russo, Mariateresa; Rastrelli, Luca
2016-01-08
This study reports a fast and automated analytical procedure for the analysis of aflatoxin M1 (AFM1) in milk and dairy products. The method is based on the simultaneous protein precipitation and AFM1 extraction, by salt-induced liquid-liquid extraction (SI-LLE), followed by an online solid-phase extraction (online SPE) coupled to ultra-high-pressure-liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) analysis to the automatic pre-concentration, clean up and sensitive and selective determination of AFM1. The main parameters affecting the extraction efficiency and accuracy of the analytical method were studied in detail. In the optimal conditions, acetonitrile and NaCl were used as extraction/denaturant solvent and salting-out agent in SI-LLE, respectively. After centrifugation, the organic phase (acetonitrile) was diluted with water (1:9 v/v) and purified (1mL) by online C18 cartridge coupled with an UHPLC column. Finally, selected reaction monitoring (SRM) acquisition mode was applied to the detection of AFM1. Validation studies were carried out on different dairy products (whole and skimmed cow milk, yogurt, goat milk, and powder infant formula), providing method quantification limits about 25 times lower than AFM1 maximum levels permitted by EU regulation 1881/2006 in milk and dairy products for direct human consumption. Recoveries (86-102%) and repeatability (RSD<3, n=6) meet the performance criteria required by EU regulation N. 401/2006 for the determination of the levels of mycotoxins in foodstuffs. Moreover, no matrix effects were observed in the different milk and dairy products studied. The proposed method improves the performance of AFM1 analysis in milk samples as AFM1 determination is performed with a degree of accuracy higher than the conventional methods. Other advantages are the reduction of sample preparation procedure, time and cost of the analysis, enabling high sample throughput that meet the current concerns of food safety and the public health protection. Copyright © 2015 Elsevier B.V. All rights reserved.
Inferring phase equations from multivariate time series.
Tokuda, Isao T; Jain, Swati; Kiss, István Z; Hudson, John L
2007-08-10
An approach is presented for extracting phase equations from multivariate time series data recorded from a network of weakly coupled limit cycle oscillators. Our aim is to estimate important properties of the phase equations including natural frequencies and interaction functions between the oscillators. Our approach requires the measurement of an experimental observable of the oscillators; in contrast with previous methods it does not require measurements in isolated single or two-oscillator setups. This noninvasive technique can be advantageous in biological systems, where extraction of few oscillators may be a difficult task. The method is most efficient when data are taken from the nonsynchronized regime. Applicability to experimental systems is demonstrated by using a network of electrochemical oscillators; the obtained phase model is utilized to predict the synchronization diagram of the system.
Tang, Chen; Lu, Wenjing; Chen, Song; Zhang, Zhen; Li, Botao; Wang, Wenping; Han, Lin
2007-10-20
We extend and refine previous work [Appl. Opt. 46, 2907 (2007)]. Combining the coupled nonlinear partial differential equations (PDEs) denoising model with the ordinary differential equations enhancement method, we propose the new denoising and enhancing model for electronic speckle pattern interferometry (ESPI) fringe patterns. Meanwhile, we propose the backpropagation neural networks (BPNN) method to obtain unwrapped phase values based on a skeleton map instead of traditional interpolations. We test the introduced methods on the computer-simulated speckle ESPI fringe patterns and experimentally obtained fringe pattern, respectively. The experimental results show that the coupled nonlinear PDEs denoising model is capable of effectively removing noise, and the unwrapped phase values obtained by the BPNN method are much more accurate than those obtained by the well-known traditional interpolation. In addition, the accuracy of the BPNN method is adjustable by changing the parameters of networks such as the number of neurons.
Albishri, Hassan M; El-Hady, Deia Abd
2014-01-01
Acrylamide in food has drawn worldwide attention since 2002 due to its neurotoxic and carcinogenic effects. These influences brought out the dual polar and non-polar characters of acrylamide as they enabled it to dissolve in aqueous blood medium or penetrate the non-polar plasma membrane. In the current work, a simple HPLC/UV system was used to reveal that the penetration of acrylamide in non-polar phase was stronger than its dissolution in polar phase. The presence of phosphate salts in the polar phase reduced the acrylamide interaction with the non-polar phase. Furthermore, an eco-friendly and costless coupling of the HPLC/UV with ionic liquid based ultrasonic assisted extraction (ILUAE) was developed to determine the acrylamide content in food samples. ILUAE was proposed for the efficient extraction of acrylamide from bread and potato chips samples. The extracts were obtained by soaking of potato chips and bread samples in 1.5 mol L(-1) 1-butyl-3-methylimmidazolium bromide (BMIMBr) for 30.0 and 60.0 min, respectively and subsequent chromatographic separation within 12.0 min using Luna C18 column and 100% water mobile phase with 0.5 mL min(-1) under 25 °C column temperature at 250 nm. The extraction and analysis of acrylamide could be achieved within 2h. The mean extraction efficiency of acrylamide showed adequate repeatability with relative standard deviation (RSD) of 4.5%. The limit of detection and limit of quantitation were 25.0 and 80.0 ng mL(-1), respectively. The accuracy of the proposed method was tested by recovery in seven food samples giving values ranged between 90.6% and 109.8%. Therefore, the methodology was successfully validated by official guidelines, indicating its reliability to be applied to analysis of real samples, proven to be useful for its intended purpose. Moreover, it served as a simple, eco-friendly and costless alternative method over hitherto reported ones. © 2013 Elsevier B.V. All rights reserved.
Cao, Jianmin; Sun, Na; Yu, Weisong; Pang, Xueli; Lin, Yingnan; Kong, Fanyu; Qiu, Jun
2016-12-01
A sensitive and robust multiresidue method for the simultaneous analysis of 114 pesticides in tobacco was developed based on solid-phase extraction coupled with gas chromatography and tandem mass spectrometry. In this strategy, tobacco samples were extracted with acetonitrile and cleaned up with a multilayer solid-phase extraction cartridge Cleanert TPT using acetonitrile/toluene (3:1) as the elution solvent. Two internal standards of different polarity were used to meet simultaneous pesticides quantification demands in the tobacco matrix. Satisfactory linearity in the range of 10-500 ng/mL was obtained for all 114 pesticides with linear regression coefficients higher than 0.994. The limit of detection and limit of quantification values were 0.02-5.27 and 0.06-17.6 ng/g, respectively. For most of the pesticides, acceptable recoveries in the range of 70-120% and repeatabilities (relative standard deviation) of <11% were achieved at spiking levels of 20, 100, and 400 ng/g. Compared with the reported multiresidue analytical method, the proposed method provided a cleaner test solution with smaller amounts of pigments, fatty acids as well as other undesirable interferences. The development and validation of the high sensitivity, high selectivity, easy automation, and high-throughput analytical method meant that it could be successfully used for the determination of pesticides in tobacco samples. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Wang, Xianli; Kang, Haiyan; Wu, Junfeng
2016-05-01
Given the potential risks of chlorinated polycyclic aromatic hydrocarbons, the analysis of their presence in water is very urgent. We have developed a novel procedure for determining chlorinated polycyclic aromatic hydrocarbons in water based on solid-phase extraction coupled with gas chromatography and mass spectrometry. The extraction parameters of solid-phase extraction were optimized in detail. Under the optimal conditions, the proposed method showed wide linear ranges (1.0-1000 ng/L) with correlation coefficients ranging from 0.9952 to 0.9998. The limits of detection and the limits of quantification were in the range of 0.015-0.591 and 0.045-1.502 ng/L, respectively. Recoveries ranged from 82.5 to 102.6% with relative standard deviations below 9.2%. The obtained method was applied successfully to the determination of chlorinated polycyclic aromatic hydrocarbons in real water samples. Most of the chlorinated polycyclic aromatic hydrocarbons were detected and 1-monochloropyrene was predominant in the studied water samples. This is the first report of chlorinated polycyclic aromatic hydrocarbons in water samples in China. The toxic equivalency quotients of chlorinated polycyclic aromatic hydrocarbons in the studied tap water were 9.95 ng the toxic equivalency quotient m(-3) . 9,10-Dichloroanthracene and 1-monochloropyrene accounted for the majority of the total toxic equivalency quotients of chlorinated polycyclic aromatic hydrocarbons in tap water. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Dong, Maofeng; Si, Wenshuai; Wang, Weimin; Bai, Bing; Nie, Dongxia; Song, Weiguo; Zhao, Zhihui; Guo, Yirong; Han, Zheng
2016-09-01
Magnetic solid-phase extraction (m-SPE) is a promising sample preparation approach due to its convenience, speed, and simplicity. For the first time, a rapid and reliable m-SPE approach using magnetic multi-walled carbon nanotubes (m-MWCNTs) as the adsorbent was proposed for purification of type A trichothecenes including T-2 toxins (T2), HT-2 toxins (HT-2), diacetoxyscirpenol (DAS), and neosolaniol (NEO) in coix seed. The m-MWCNTs were synthesized by assembling the magnetic nanoparticles (Fe3O4) with MWCNTs by sonication through an aggregation wrap mechanism, and characterized by transmission electron microscope. Several key parameters affecting the performance of the procedure were extensively investigated including extraction solutions, desorption solvents, and m-MWCNT amounts. Under the optimal sample preparation conditions followed by analysis with ultra-high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS), high sensitivity (limit of quantification in the range of 0.3-1.5 μg kg(-1)), good linearity (R (2) > 0.99), satisfactory recovery (73.6-90.6 %), and acceptable precision (≤2.5 %) were obtained. The analytical performance of the developed method has also been successfully evaluated in real coix seed samples. Graphical Abstract Flow chart of determination of type A trichothecenes in coix seed by magnetic solid-phase extraction coupled with ultra-high performance liquid chromatography-tandem mass spectrometry.
Lawal, Abubakar; Wong, Richard Chee Seng; Tan, Guan Huat; Abdulra'uf, Lukman Bola; Alsharif, Ali Mohamed Ali
2018-04-21
Fruits and vegetables constitute a major type of food consumed daily apart from whole grains. Unfortunately, the residual deposits of pesticides in these products are becoming a major health concern for human consumption. Consequently, the outcome of the long-term accumulation of pesticide residues has posed many health issues to both humans and animals in the environment. However, the residues have previously been determined using conventionally known techniques, which include liquid-liquid extraction, solid-phase extraction (SPE) and the recently used liquid-phase microextraction techniques. Despite the positive technological effects of these methods, their limitations include; time-consuming, operational difficulty, use of toxic organic solvents, low selective property and expensive extraction setups, with shorter lifespan of instrumental performances. Thus, the potential and maximum use of these methods for pesticides residue determination has resulted in the urgent need for better techniques that will overcome the highlighted drawbacks. Alternatively, attention has been drawn recently towards the use of quick, easy, cheap, effective, rugged and safe technique (QuEChERS) coupled with dispersive solid-phase extraction (dSPE) to overcome the setback challenges experienced by the previous technologies. Conclusively, the reviewed QuEChERS-dSPE techniques and the recent cleanup modifications justifiably prove to be reliable for routine determination and monitoring the concentration levels of pesticide residues using advanced instruments such as high-performance liquid chromatography, liquid chromatography-mass spectrometry and gas chromatography-mass spectrometry.
Ares, Ana M; Valverde, Silvia; Bernal, José L; Toribio, Laura; Nozal, María J; Bernal, José
2017-10-01
In this study, a new method has been developed to determine flubendiamide in honey using liquid chromatography coupled to a selective mass spectrometry detector (quadrupole-time-of-flight). An efficient sample treatment involving a solid phase extraction with a C 18 sorbent was proposed (average analyte recoveries were between 94 and 104%). Chromatographic analysis (9min) was performed on a C 18 column (Gemini C 18 , 50×2.0mm, 3µm, 110Å). The mobile phase consisted of water and acetonitrile, with a flow rate of 0.5mL/min in gradient elution mode. The method was fully validated in terms of selectivity, limits of detection and quantification, matrix effect, linearity, trueness and precision. Low limits of detection and quantification were obtained, ranging from 0.1 to 0.2µg/kg and 0.4 to 0.6µg/kg, respectively. The method was applied to analyze flubendiamide in honey from different botanic origins (multifloral, rosemary and heather). Copyright © 2017 Elsevier Ltd. All rights reserved.
A novel hybrid metal-organic framework-polymeric monolith for solid-phase microextraction.
Lin, Chen-Lan; Lirio, Stephen; Chen, Ya-Ting; Lin, Chia-Her; Huang, Hsi-Ya
2014-03-17
This study describes the fabrication of a novel hybrid metal-organic framework- organic polymer (MOF-polymer) for use as a stationary phase in fritless solid-phase microextraction (SPME) for validating analytical methods. The MOF-polymer was prepared by using ethylene dimethacrylate (EDMA), butyl methacrylate (BMA), and an imidazolium-based ionic liquid as porogenic solvent followed by microwave-assisted polymerization with the addition of 25 % MOF. This novel hybrid MOF-polymer was used to extract penicillin (penicillin G, penicillin V, oxacillin, cloxacillin, nafcillin, dicloxacillin) under different conditions. Quantitative analysis of the extracted penicillin samples using the MOF-organic polymer for SPME was conducted by using capillary electrochromatography (CEC) coupled with UV analysis. The penicillin recovery was 63-96.2 % with high reproducibility, sensitivity, and reusability. The extraction time with the proposed fabricated SPME was only 34 min. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Solid-phase extraction NMR studies of chromatographic fractions of saponins from Quillaja saponaria.
Nyberg, Nils T; Baumann, Herbert; Kenne, Lennart
2003-01-15
The saponin mixture QH-B from the tree Quillaja saponaria var. Molina was fractionated by RP-HPLC in several steps. The fractions were analyzed by solid-phase extraction NMR (SPE-NMR), a technique combining the workup by solid-phase extraction with on-line coupling to an NMR flow probe. Together with MALDI-TOF mass spectrometry and comparison with chemical shifts of similar saponins, the structures of both major and minor components in QH-B could be obtained. The procedure described is a simple method to determine the structure of components in a complex mixture. The two major fractions of the mixture were found to contain at least 28 saponins, differing in the carbohydrate substructures. Eight of these have not previously been determined. The 28 saponins formed 14 equilibrium pairs by the migration of an O-acyl group between two adjacent positions on a fucosyl residue.
Wang, Huilin; Jiang, Yan; Ding, Mingya; Li, Jin; Hao, Jia; He, Jun; Wang, Hui; Gao, Xiu-Mei; Chang, Yan-Xu
2018-02-03
A simple and effective sample preparation process based on miniaturized matrix solid-phase dispersion was developed for simultaneous determination of phenolic acids (gallic acid, chlorogenic acid, ferulic acid, 3,5-dicaffeoylqunic acid, 1,5-dicaffeoylqunic acid, rosmarinic acid, lithospermic acid, and salvianolic acid B), flavonoids (kaempferol-3-O-rutinoside, calycosin, and formononetin), lactones (ligustilide and butyllidephthalide), monoterpenoids (paeoniflorin), phenanthraquinones (cryptotanshinone), and furans (5-hydroxymethylfurfural) in Naoxintong capsule by ultra high-performance liquid chromatography. The optimized condition was that 25 mg Naoxintong powder was blended homogeneously with 100 mg Florisil PR for 4 min. One milliliter of methanol/water (75:25, v/v) acidified by 0.05% formic acid was selected to elute all components. It was found that the recoveries of the six types of components ranged from 61.36 to 96.94%. The proposed miniaturized matrix solid-phase dispersion coupled with ultra high-performance liquid chromatography was successfully applied to simultaneous determination of the six types of components in Naoxintong capsules. The results demonstrated that the proposed miniaturized matrix solid-phase dispersion coupled with ultra high-performance liquid chromatography could be used as an environmentally friendly tool for the extraction and determination of multiple bioactive components in natural products. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Yuan, Su-Fen; Liu, Ze-Hua; Lian, Hai-Xian; Yang, Chuang-Tao; Lin, Qing; Yin, Hua; Lin, Zhang; Dang, Zhi
2018-02-01
A fast and reliable method was developed for simultaneous trace determination of nine odorous and estrogenic chloro- and bromo-phenolic compounds (CPs and BPs) in water samples using solid-phase extraction (SPE) coupled with liquid chromatography tandem mass spectrometry (LC-MS/MS). For sample preparation, the extraction efficiencies of two widely applied cartridges Oasis HLB and Sep-Pak C18 were compared, and the Oasis HLB cartridge showed much better extraction performance; pH of water sample also plays important role on extraction, and pH = 2-3 was found to be most appropriate. For separation of the target compounds, small addition of ammonium hydroxide can obviously improve the detection sensitivity, and the optimized addition concentration was determined as 0.2%. The developed efficient method was validated and showed excellent linearity (R 2 > 0.995), low limit of detection (LOD, 1.9-6.2 ng/L), and good recovery efficiencies of 57-95% in surface and tap water with low relative standard deviation (RSD, 1.3-17.4%). The developed method was finally applied to one tap and one surface water samples and most of these nine targets were detected, but all of them were below their odor thresholds, and their estrogen equivalent (EEQ) were also very low.
Ma, Jiping; Lu, Xi; Xia, Yan; Yan, Fengli
2015-02-01
A solid-phase extraction (SPE) method using multi-walled carbon nanotubes as adsorbent coupled with high-performance liquid chromatography was developed for the determination of four pyrazole and pyrrole pesticides (fenpyroximate, chlorfenapyr, fipronil and flusilazole) in environmental water samples. Several parameters, such as extraction adsorbent, elution solvent and volume and sample loading flow rate were optimized to obtain high SPE recoveries and extraction efficiency. The calibration curves for the pesticides extracted were linear in the range of 0.05-10 μg L(-1) for chlorfenapyr and fenpyroximate and 0.05-20 μg L(-1) for fipronil and flusilazole, with the correlation coefficients (r(2)) between 0.9966 and 0.9990. The method gave good precisions (relative standard deviation %) from 2.9 to 10.1% for real spiked samples from reservoir water and seawater; method recoveries ranged 92.2-105.9 and 98.5-103.9% for real spiked samples from reservoir water and seawater, respectively. Limits of detection (S/N = 3) for the method were determined to be 8-19 ng L(-1). The optimized method was successfully applied to the determination of four pesticides of pyrazoles and pyrroles in real environmental water samples. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Li, Longfei; Su, Min; Shi, Xiaolei; Wang, Yana; Wang, Minmin; He, Jinxing
2014-02-01
A method for the determination of diethylstilbestrol (DES), hexestrol (HEX) and dienestrol (DS) residues in drinking water was established by on-line solid phase extraction (SPE) coupled with high performance liquid chromatography (HPLC). The material synthesized on the base of sol-gel technology was employed as adsorbent. This material was prepared using 3-aminopropyltriethoxysilane (APTES) as the functional monomer, tetraethoxysilane (TEOS) as the crosslinking agent, and acetic acid as the initiator. The synthesized adsorbent showed outstanding property for the estrogen extraction. The estrogen can be caught effectively from water samples and the extraction can be achieved rapidly. Some important parameters, such as pH of sample solution, eluent solvents, loading flow rate, which might influence extraction efficiency, were optimized. The results indicated that the limit of detection (S/N = 3) of the developed method could reach 0.07-0.13 microg/L under the conditions of pH 7.0 of sample solution, methanol and 1% (v/v) acetic acid aqueous solution as the eluent solvent and the loading flow rate of 2 mL/min. The recoveries of the three estrogens from the water samples at three spiked levels ranged from 82.31% to 99.43% with RSD of 1.61%-7.15%. The method was simple, rapid, and suitable to detect the trace residues of estrogens in drinking water.
Ji, Shuai; He, Dan-Dan; Wang, Tian-Yun; Han, Jie; Li, Zheng; Du, Yan; Zou, Jia-Hui; Guo, Meng-Zhe; Tang, Dao-Quan
2017-11-30
Ginkgo biloba extract (GBE), derived from the leaves of Ginkgo biloba L., is one of the most widely used traditional Chinese medicines worldwide. Due to high structural diversity and low abundance of chemical constituents in GBE, conventional reversed-phase liquid chromatography has limited power to meet the needs of its quality control. In this study, an off-line hydrophilic interaction×reversed-phase two-dimensional liquid chromatography (HILIC×RP 2D-LC) system coupled with diode array detection (DAD) and quadrupole time-of-flight mass spectrometry (qTOF-MS) was established to comprehensively analyze the chemical constituents of GBE. After optimizing the chromatographic columns and mobile phase of 2D-LC, a Waters XBridge Amide column using acetonitrile/water/formic acid as the mobile phase was selected as the first dimension to fractionate GBE, and the obtained fractions were further separated on an Agilent Zorbax XDB-C18 column with methanol/water/formic acid as the mobile phase. As a result, a total of 125 compounds were detected in GBE. The orthogonality of the 2D-LC system was 69.5%, and the practical peak capacity was 3864 and 2994, respectively, calculated by two different methods. The structures of 104 compounds were tentatively characterized by qTOF-MS analysis, and 21 of them were further confirmed by comparing with reference standards. This established HILIC×RP 2D-LC-qTOF/MS system can greatly improve the separation and characterization of natural products in GBE or other complicated herbal extracts. Copyright © 2017 Elsevier B.V. All rights reserved.
Jian, Wenjuan; Chen, Minyou; McFarland, Dennis J
2017-11-01
Phase-locking value (PLV) is a potentially useful feature in sensorimotor rhythm-based brain-computer interface (BCI). However, volume conduction may cause spurious zero-phase coupling between two EEG signals and it is not clear whether PLV effects are independent of spectral amplitude. Volume conduction might be reduced by spatial filtering, but it is uncertain what impact this might have on PLV. Therefore, the goal of this study was to explore whether zero-phase PLV is meaningful and how it is affected by spatial filtering. Both amplitude and PLV feature were extracted in the frequency band of 10-15 Hz by classical methods using archival EEG data of 18 subjects trained on a two-target BCI task. The results show that with right ear-referenced data, there is meaningful long-range zero-phase synchronization likely involving the primary motor area and the supplementary motor area that cannot be explained by volume conduction. Another novel finding is that the large Laplacian spatial filter enhances the amplitude feature but eliminates most of the phase information seen in ear-referenced data. A bipolar channel using phase-coupled areas also includes both phase and amplitude information and has a significant practical advantage since fewer channels required.
Sun, Min; Feng, Juanjuan; Bu, Yanan; Luo, Chuannan
2015-08-21
A fiber-in-tube solid-phase microextraction (SPME) device was developed with copper wire and copper tube, which was served as both the substrate and sorbent with high physical strength and good flexibility. Its morphology and surface properties were characterized by scanning electron microscopy and energy dispersive X-ray spectrometry. It was coupled with high performance liquid chromatography (HPLC) equipment by replacing the sample loop of six-port injection valve, building the online SPME-HPLC system conveniently. Using ten polycyclic aromatic hydrocarbons (PAHs) as model analytes, extraction conditions including sampling rate, extraction time, organic content and desorption time were investigated and optimized. The copper fiber-in-tube exhibits excellent extraction efficiency toward PAHs, with enrichment factors from 268 to 2497. The established online SPME-HPLC method provides good linearity (0.05-100μgL(-1)) and low detection limits (0.001-0.01μgL(-1)) for PAHs. It has been used to determine PAHs in water samples, with recoveries in the range of 86.2-115%. Repeatability on the same extraction tube is in the range of 0.6-3.6%, and repeatability among three tubes is in the range of 5.6-20.1%. Compared with phthalates, anilines and phenols, the copper fiber-in-tube possesses good extraction selectivity for PAHs. The extraction mechanism is probably related to hydrophobic interaction and π-electron-metal interaction. Copyright © 2015 Elsevier B.V. All rights reserved.
Tang, Sheng; Lee, Hian Kee
2016-05-15
A novel syringe needle-based sampling approach coupled with liquid-phase extraction (NBS-LPE) was developed and applied to the extraction of l-ascorbic acid (AsA) in apple. In NBS-LPE, only a small amount of apple flesh (ca. 10mg) was sampled directly using a syringe needle and placed in a glass insert for liquid extraction of AsA by 80 μL oxalic acid-acetic acid. The extract was then directly analyzed by liquid chromatography. This new procedure is simple, convenient, almost organic solvent free, and causes far less damage to the fruit. To demonstrate the applicability of NBS-LPE, AsA levels at different sampling points in a single apple were determined to reveal the spatial distribution of the analyte in a three-dimensional model. The results also showed that this method had good sensitivity (limit of detection of 0.0097 mg/100g; limit of quantification of 0.0323 mg/100g), acceptable reproducibility (relative standard deviation of 5.01% (n=6)), a wide linear range of between 0.05 and 50mg/100g, and good linearity (r(2)=0.9921). This interesting extraction technique and modeling approach can be used to measure and monitor a wide range of compounds in various parts of different soft-matrix fruits and vegetables, including single specimens. Copyright © 2015 Elsevier Ltd. All rights reserved.
Leite, Tonny Cley Campos; de Sena, Amanda Reges; dos Santos Silva, Tânia Regina; dos Santos, Andrea Karla Almeida; Uetanabaro, Ana Paula Trovatti; Branco, Alexsandro
2012-01-01
Background: Marcetia genera currently comprises 29 species, with approximately 90% inhabiting Bahia (Brazil), and most are endemic to the highlands of the Chapada Diamantina (Bahia). Among the species, only M. taxifolia (A.St.-Hil.) DC. populates Brazil (state of Roraima to Paraná) and also Venezuela, Colombia, and Guyana. Objective: This work evaluated the antimicrobial activity of hexane, ethyl acetate, and methanol extracts of three species of Marcetia (Marcetia canescens Naud., M. macrophylla Wurdack, and M. taxifolia A.StHil) against several microorganism. In addition, the flavonoids were analyzed in extracts by HPLC-DAD. Materials and methods: The tests were made using Gram-positive (three strains of Staphylococcus aureus) and Gram-negative (two strains of Escherichia coli, a strain of Pseudomonas aeruginosa and another of Salmonella choleraesius) bacteria resistant and nonresistant to antibiotics and yeasts (two strains of Candida albicans and one of C. parapsilosis) by the disk diffusion method. Solid-phase extraction (SPE) was performed on the above extracts to isolate flavonoids, which were subsequently analyzed by high performance liquid chromatography coupled diode array detector (HPLC-DAD). Results: Results showed that extracts inhibited the Gram-positive bacteria and yeast. The hexane extracts possessed the lowest activity, while the ethyl acetate and methanolic extracts were more active. Conclusion: Marcetia taxifolia was more effective (active against 10 microorganisms studied), and only its methanol extract inhibited Gram-negative bacteria (P. aeruginosa and S. choleraesius). SPE and HPLC-DAD analysis showed that M. canescens and M. macrophylla contain glycosylated flavonoids, while the majority of extracts from M. taxifolia were aglycone flavonoids. PMID:23060695
Wang, Lingling; Zhang, Zhenzhen; Xu, Xu; Zhang, Danfeng; Wang, Fang; Zhang, Lei
2015-09-01
A simple, rapid, sensitive and effective method for the simultaneous determination of four endocrine disrupting compounds (EDCs) (bisphenol A (BPA), bisphenol F (BPF), bisphenol AF (BPAF) and bisphenol AP (BPAP)) in environment water samples based on solid-phase microextraction (SPME) coupled with high performance liquid chromatography (HPLC) was developed. Multi-wall carbon nanotubes (MWCNTs) adsorbents showed a good affinity to the target analytes. These compounds were rapidly extracted within 10 min. Various experimental parameters that could affect the extraction efficiencies had been investigated in detail. Under the optimum conditions, the enrichment factors of the method for the target EDCs were found to be 500. Satisfactory precision and accuracy of the method were obtained in a low concentration range of 2.0-500.0 ng mL(-1). The method detection limits were in the range of 0.10-0.30 ng mL(-1). The high pre-concentration rate and efficiency of the method ensure its successful application in extraction of trace EDCs from large volumes of environmental water samples. The extraction recoveries in real samples ranged from 85.3% to 102.5% with the relative standard deviations (n=5) less than 3.74%. Copyright © 2015 Elsevier B.V. All rights reserved.
Xie, Xintong; Wang, Junhui; Zheng, Juan; Huang, Junlong; Ni, Chuyi; Cheng, Jie; Hao, Zhengping; Ouyang, Gangfeng
2018-10-31
A cost-effective microporous polymer was synthesized using cheap monomer and catalyst via one-step Scholl-coupling reaction, and its chemical, morphological characteristics and pore structure were investigated. The as-synthesized polymer with large surface area and narrow pore distribution (centered in 1.2 nm) was prepared as a fiber coating for solid-phase microextraction (SPME). Headspace SPME was used for the extraction of the light aromatic compounds, e.g. benzene, toluene, ethylbenzene, m-xylene, naphthalene and acenaphthene. The parameters influencing the extraction and desorption efficiencies, such as extraction temperature and time, salt concentration, desorption temperature and time were investigated and optimized. The results showed that the home-made fiber had superior extraction efficiencies compared with the commercial PDMS fiber. Under the optimized conditions, low detection limits (0.01-1.3 ng/L), wide linear ranges (from 50 to 20000 ng/L to 1-20000 ng/L), good repeatability (4.2-9.3%, n = 6) and reproducibility (0.30-11%, n = 3) were achieved. Moreover, the practical applicability of the coating and proposed method was evaluated by determining the target light aromatic compounds in environmental water samples with satisfied recoveries (83.2%-116%). Copyright © 2018 Elsevier B.V. All rights reserved.
Moein, Mohammad Mahdi; Javanbakht, Mehran; Akbari-Adergani, Behrouz
2011-04-01
In this paper, a novel method is described for automated determination of dextromethorphan in biological fluids using molecularly imprinted solid-phase extraction (MISPE) as a sample clean-up technique combined with high performance liquid chromatography (HPLC). The water-compatible molecularly imprinted polymers (MIPs) were prepared using methacrylic acid as functional monomer, ethylene glycol dimethacrylate as cross-linker, chloroform as porogen and dextromethorphan as template molecule. These imprinted polymers were used as solid-phase extraction sorbent for the extraction of dextromethorphan from human plasma samples. Various parameters affecting the extraction efficiency of the MIP cartridges were evaluated. The high selectivity of the sorbent coupled to the high performance liquid chromatographic system permitted a simple and rapid analysis of this drug in plasma samples with limits of detection (LOD) and quantification (LOQ) of 0.12 ng/mL and 0.35 ng/mL, respectively. The MIP selectivity was evaluated by analyzing of the dextromethorphan in presence of several substances with similar molecular structures and properties. Results from the HPLC analyses showed that the recoveries of dextromethorphan using MIP cartridges from human plasma samples in the range of 1-50 ng/mL were higher than 87%. Copyright © 2011 Elsevier B.V. All rights reserved.
Sun, Shi-Hao; Xie, Jian-Ping; Xie, Fu-Wei; Zong, Yong-Li
2008-02-01
A method coupling needle-based derivatization headspace liquid-phase microextraction with gas chromatography-mass spectrometry (HS-LPME/GC-MS) was developed to determine volatile organic acids in tobacco. The mixture of N,O-bis(trimethylsilyl)trifluoroacetamide and decane was utilized as the solvent for HS-LPME, resulting that extraction and derivatization were simultaneously completed in one step. The solvent served two purposes. First, it pre-concentrated volatile organic acids in the headspace of tobacco sample. Second, the volatile organic acids extracted were derivatized to form silyl derivatives in the drop. The main parameters affecting needle-based derivatization HS-LPME procedure such as extraction and derivatization reagent, microdrop volume, extraction and derivatization time, and preheating temperature and preheating time were optimized. The standard addition approach was essential to obtain accurate measurements by minimizing matrix effects. Good linearity (R(2)> or =0.9804) and good repeatability (RSDs< or =15.3%, n=5) for 16 analytes in spiked standard analytes sample were achieved. The method has the additional advantages that at the same time it is simple, fast, effective, sensitive, selective, and provides an overall profile of volatile organic acids in the oriental tobacco. This paper does offer an alternative approach to determine volatile organic acids in tobacco.
Zeng, Honglian; Liu, Zhenli; Zhao, Siyu; Shu, Yisong; Song, Zhiqian; Wang, Chun; Dong, Yunzhuo; Ning, Zhangchi; He, Dan; Wang, Menglei; Lu, Cheng; Liu, Yuanyan; Lu, Aiping
2016-10-01
Citrus fruit is an important health-promoting food that is rich in dietary phenolic metabolites. Traditional Chinese medicines, such as Zhishi and Zhiqiao, come from young and immature fruits of Citrus cultivars. The preparation of diversified bioactive phenolic products and establishment of the corresponding quality control methodology are challenging and necessary. In the current study, four types of solid-phase extraction sorbents for the enrichment and clean-up of the phenolic matrix were evaluated. A solid-phase extraction column coated with Strata-X was finally used in the procedure. Twenty phenolic compounds were selected to evaluate the extraction performances of the sorbents using high-performance liquid chromatography analysis. Under the optimized conditions, good linearities were obtained with R 2 more than 0.9996 for all analytes with LODs of 0.04-1.012 μg/g. Intra- and interday relative standard deviation values were less than 3%, and the recovery was equal to or higher than 90.02%. Compared to non-solid-phase extraction process, the content of total phenolic products was elevated 35.55-68.48% with solid-phase extraction. Finally, the developed and validated method was successfully applied to the discrimination of Zhishi samples from different species as well as Zhishi and Zhiqiao samples in different development stages. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Gao, Li; Wei, Yinmao
2016-08-01
A novel mixed-mode adsorbent was prepared by functionalizing silica with tris(2-aminoethyl)amine and 3-phenoxybenzaldehyde as the main mixed-mode scaffold due to the presence of the plentiful amino groups and benzene rings in their molecules. The adsorption mechanism was probed with acidic, natural and basic compounds, and the mixed hydrophobic and ion-exchange interactions were found to be responsible for the adsorption of analytes. The suitability of dispersive solid-phase extraction was demonstrated in the determination of chlorophenols in environmental water. Several parameters, including sample pH, desorption solvent, ionic strength, adsorbent dose, and extraction time were optimized. Under the optimal extraction conditions, the proposed dispersive solid-phase extraction coupled with high-performance liquid chromatography showed good linearity range and acceptable limits of detection (0.22∽0.54 ng/mL) for five chlorophenols. Notably, the higher extraction recoveries (88.7∽109.7%) for five chlorophenols were obtained with smaller adsorbent dose (10 mg) and shorter extraction time (15 min) compared with the reported methods. The proposed method might be potentially applied in the determination of trace chlorophenols in real water samples. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Composition and Molecular Weight Distribution of Carob Germ Proteins Fractions
USDA-ARS?s Scientific Manuscript database
Biochemical properties of carob germ proteins were analyzed using a combination of selective extraction, reversed-phase high performance liquid chromatography (RP-HPLC), size exclusion chromatography coupled with multi-angle laser light scattering (SEC-MALS) and electrophoretic analysis. Using a mo...
Molecular imprinting solid phase extraction for selective detection of methidathion in olive oil.
Bakas, Idriss; Oujji, Najwa Ben; Moczko, Ewa; Istamboulie, Georges; Piletsky, Sergey; Piletska, Elena; Ait-Ichou, Ihya; Ait-Addi, Elhabib; Noguer, Thierry; Rouillon, Régis
2012-07-13
A specific adsorbent for extraction of methidathion from olive oil was developed. The design of the molecularly imprinted polymer (MIP) was based on the results of the computational screening of the library of polymerisable functional monomers. MIP was prepared by thermal polymerisation using N,N'-methylene bisacrylamide (MBAA) as a functional monomer and ethylene glycol dimethacrylate (EGDMA) as a cross-linker. The polymers based on the itaconic acid (IA), methacrylic acid (MAA) and 2-(trifluoromethyl)acryl acid (TFMAA) functional monomers and one control polymer which was made without functional monomers with cross-linker EGDMA were also synthesised and tested. The performance of each polymer was compared using corresponding imprinting factor. As it was predicted by molecular modelling the best results were obtained for the MIP prepared with MBAA. The obtained MIP was optimised in solid-phase extraction coupled with high performance liquid chromatography (MISPE-HPLC-UV) and tested for the rapid screening of methidathion in olive oil. The proposed method allowed the efficient extraction of methidathion for concentrations ranging from 0.1 to 9 mg L(-1) (r(2)=0.996). The limits of detection (LOD) and quantification (LOQ) in olive oil were 0.02 mg L(-1) and 0.1 mg L(-1), respectively. MIPs extraction was much more effective than traditional C18 reverse-phase solid phase extraction. Copyright © 2012 Elsevier B.V. All rights reserved.
Wang, Jincheng; Xiong, Li; Zhang, Haijun; Chen, Jiping
2011-12-01
A simple method based on solid phase extraction (SPE) coupled with high performance liquid chromatography-mass spectrometry (HPLC-MS) was developed for the determination of octylphenol (OP), nonylphenol (NP), octylphenol ethoxylates (OPEOs) and nonylphenol ethoxylates (NPEOs) in brine. The extraction and cleanup of brine samples were performed on C18 solid-phase extraction cartridges. The complete separation among OP, NP, OPEOs and NPEOs was achieved on a Hypersil GOLD analytical column with methanol-water as the mobile phase. The determination was achieved using HPLC-MS with electrospray ionization (ESI) in selected ion monitoring mode. The results showed that the average recoveries of target compounds were 59.6% - 104.4% and the corresponding relative standard deviations (RSDs, n = 3) were 1.0% - 13.5%. The instrumental limits of detection for the compounds were 0.08 - 3 microg/L. This method was applied to the analysis of the samples of seawater near Dalian coast. The results showed that both NP and NPEOs were detected in all samples and their concentrations in seaport and oil port were much higher than those in other sampling sites.
Zhou, Xuan; Chen, Cen; Ye, Xiaolan; Song, Fenyun; Fan, Guorong; Wu, Fuhai
2016-04-01
In this study, a method coupling turbulent flow chromatography with online solid-phase extraction and high-performance liquid chromatography with tandem mass spectrometry was developed for analyzing the lignans in Magnoliae Flos. By the online pretreatment of turbulent flow chromatography solid-phase extraction, the impurities removal and analytes concentration were automatically processed, and the lignans were separated rapidly and well. Seven lignans of Magnoliae Flos including epieudesmin, magnolin, 1-irioresinol-B-dimethyl ether, epi-magnolin, fargesin aschantin, and demethoxyaschantin were identified by comparing their retention behavior, UV spectra, and mass spectra with those of reference substances or literature data. The developed method was validated, and the good results showed that the method was not only automatic and rapid, but also accurate and reliable. The turbulent flow chromatography with online solid-phase extraction and high-performance liquid chromatography with tandem mass spectrometry method holds a high potential to become an effective method for the quality control of lignans in Magnoliae Flos and a useful tool for the analysis of other complex mixtures. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Yu, Li; Ma, Fei; Ding, Xiaoxia; Wang, Hengling; Li, Peiwu
2018-04-15
Graphene oxide wrapped silica nanocomposites were synthesized and selected as solid phase extraction adsorbents for high performance liquid chromatography analysis of aflatoxins. The major parameters affecting extraction efficiency were optimized, including the amount of adsorbents, extraction time and desorption conditions. The limit of detections and the limit of quantifications were from 0.1 to 0.3 µg/kg and from 0.3 to 1.0 µg/kg, respectively. The recoveries of aflatoxins in the spiked maize and rice samples were in the range of 76.8-104.7% and 81.1-106.9%, respectively, and with the RSDs less than 12.4%. The proposed method was proven to be simple, rapid and reliable for routine analysis of aflatoxins in crops. Copyright © 2017 Elsevier Ltd. All rights reserved.
Yu, Jianxin; Wu, Caiying; Xing, Jun
2004-05-21
Allyloxy bisbenzo 16-crown-5 trimethoxysilane was first used as precursor to prepare the sol-gel-derived bisbenzo crown ether/hydroxyl-terminated silicone oil (OH-TSO) SPME coating. The coating procedure involving sol solution composition and conditioning process was presented. Compared with commercial SPME stationary phases, the new coatings showed higher extraction efficiency and therefore could provide higher sensitivity for organphosphorous pesticides (OPs). Limits of detection (LODs) were in the range of 0.003-1.0 ng/g for these OPs in food samples (honey, juice, orange and pakchoi). The optimal extraction conditions of the new coatings to OPs in these samples were investigated by adjusting extraction time, salt addition, extraction temperature, and dilution ratios of samples with distilled water by using SPME coupled with gas chromatography (GC)-flame photometric detection (FPD). The method was applied to determine the concentrations of OPs in real samples.
Taghani, Abdollah; Goudarzi, Nasser; Bagherian, Ghadamali; Chamjangali, Mansour Arab
2017-01-01
A rapid, simple, and sensitive technique is proposed based on a miniaturized solid-phase extraction method named mictroextraction in a packed syringe coupled with gas chromatography-mass spectrometry for the preconcentration and determination of three organochlorine pesticides. These include hexachlorobenzene, heptachlor and aldrine in aqueous samples. For the first time, the natural nano diatomite is used a sorbent. Based on this technique, 6.0 mg of the nano sorbent is inserted in a syringe between two polypropylene frits. The analytes would be adsorbed on the solid phase, and would subsequently be eluted using organic solvents. The influence of some important parameters, such as the solution pH, type and volume of the organic desorption solvent, and amount of sorbent on the extraction efficiency of the selected pesticides, is investigated. The proposed method shows good linearity in the range of 0.1 - 40.0 μg L -1 , and at low limits of detection in the range of 0.02 - 0.13 μg L -1 using the selected ion-monitoring mode. The reproducibility of this method was found to be in the range of 3.5 - 11.1% for the understudied pesticides. In order to evaluate the matrix effect, the developed method is also applied to the preconcentration and determination of the selected pesticides in different water samples.
Shi, Ao
2016-02-01
A method has been developed for the simultaneous determination of 23 antibiotics (four categories) and 3 β-agonists in livestock drinking water using solid-phase extraction and ultra performance liquid chromatography coupled with electrospray ionization tandem mass spectrometry (UPLC-ESI MS/MS). The samples were adjusted pH to 5. 0, added Na2EDTA, enriched and cleaned-up by an HLB solid-phase extraction cartridge. The target compounds were confirmed and quantified by UPLC-ESI MS/MS with external standard method for the anti- biotics and internal standard method for the β-agonists. The recoveries were assessed by using lab tap water as matrix. The average recoveries of the 23 antibiotics and the 3 β-agonists were in the range of 50. 7%-104. 6% and the relative standard deviations (RSDs) were 2. 6%-8. 8% (n= 3). Under the optimal conditions, the calibration curves of the 23 antibiotics and the 3 β-agonists showed good linearity with the correlation coefficients better than 0. 994. The limits of detection (LODs, S/N≥3) ranged from 0. 01-0. 20 ng/L. The developed method was applied to analyze the livestock drinking waters in 36 Beijing intensive livestock farms. The results showed that some antibiotics were detected.
Zhang, Weiya; Wan, Xin; Li, Lixia; Wang, Chengyun; Jin, Shupei; Xing, Jun
2014-10-01
The short chain chlorinated paraffins (SCCPs) are the additives frequently used in the leather production in China, but they have been put into the list of forbidden chemicals issued by European Union recently. In fact, there is not a commonly recognized method for the determination of the SCCPs in the leather products due to the serious matrix interferences from the leather products and the complex chemical structures of the SCCPs. A method of solid phase extraction coupled with gas chromatography-mass spectrometry (SPE-GC-MS) was established for the determination of the SCCPs in the leather products after the optimization of the SPE conditions. It was found that the interferences from the leather products were thor- oughly separated from the analyte of the SCCPs on a home-made solid phase extraction (SPE) column filled with silica packing while eluted with a mixed solvent of n-hexane-methylene chloride (2:1, v/v). With this method, the recoveries for the SCCPs spiked in the real leather samples varied from 90.47% to 99.00% with the relative standard deviations (RSDs) less than 6.7%, and the limits of detection (LODs) were between 0.069 and 0.110 mg/kg. This method is suitable for qualitative and quantitative analysis of SCCPs in the leather products.
Li, Jinhua; Liu, Junying; Lu, Wenhui; Gao, Fangfang; Wang, Liyan; Ma, Jiping; Liu, Huitao; Liao, Chunyang; Chen, Lingxin
2018-04-23
A pretreatment method of dispersive solid-phase extraction (DSPE) along with back-extraction followed by CE-UV detector was developed for the determination of mercury species in water samples. Sulfhydryl-functionalized SiO 2 microspheres (SiO 2 -SH) were synthesized and used as DSPE adsorbents for selective extraction and enrichment of three organic mercury species namely ethylmercury (EtHg), methylmercury (MeHg), and phenylmercury (PhHg), along with L-cysteine (L-cys) containing hydrochloric acid as back-extraction solvent. Several main extraction parameters were systematically investigated including sample pH, amount of adsorbent, extraction and back-extraction time, volume of eluent, and concentration of hydrochloric acid. Under optimal conditions, good linearity was achieved with correlation coefficients over 0.9990, in the range of 4-200 μg/L for EtHg, and 2-200 μg/L for MeHg and PhHg. The LODs were obtained of 1.07, 0.34, and 0.24 μg/L for EtHg, MeHg, and PhHg, respectively, as well as the LOQs were 3.57, 1.13, and 0.79 μg/L, respectively, with enrichment factors ranging from 109 to 184. Recoveries were attained with tap and lake water samples in a range of 62.3-107.2%, with relative standard deviations of 3.5-10.1%. The results proved that the method of SiO 2 -SH based DSPE coupled with CE-UV was a simple, rapid, cost-effective, and eco-friendly alternative for the determination of mercury species in water samples. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Bartosiak, Magdalena; Jankowski, Krzysztof; Giersz, Jacek
2018-06-05
Cobalt content (as vitamin B 12 and inorganic cobalt) in two nutritional supplements, namely Spirulina platensis and Saccharomyces cerevisiae known as a "superfood", has been determined using inductively coupled plasma optical emission spectrometry (ICP-OES). Several sample pre-treatment protocols have been applied and compared. Microwave-assisted acid digestion efficiently decomposed all cobalt-containing compounds, thus allowed obtaining total cobalt content in supplements examined. Vitamin B 12 was extracted from the samples with acetate buffer and potassium cyanide solution exposed to mild microwave radiation for 30 min, and cyanocobalamin was separated from the extract by on-column solid phase extraction using C-18 modified silica bed. About 100% of cobalt species was extracted using the triple microwave-assisted extraction procedure. Total cobalt content was 20-fold greater in Spirulina tablets than the declared cobalamin content (as Co). The ICP-OES method precision was about 3% and detection limit was 1.9 and 2.7 ng Co mL -1 for inorganic cobalt or cyanocobalamin, respectively. Copyright © 2018 Elsevier B.V. All rights reserved.
Ren, Xiulian; Wei, Qifeng; Chen, Yongxing; Guo, Jingjing; Wei, Sijie; Wang, Xiaofei
2015-12-15
The pollution risk of dilute acidic sulfate effluent (DASE),which is discharged from titanium dioxide factories heavily every year, has sparked the recycling of sulfuric acid, iron and water. In this study, a new green recovery process for the DASE is proposed based on coupling solventextraction-oxidation-hydrolysis. Compared to the conventional ways, this innovative method allows the effective extraction of sulfuric acid and the precipitation of FexOy·nH2O in onestep without adding inorganic neutralizer or precipitant. Trioctylamine (TOA) in kerosene (20-50%) was used as an organic phase for solvent extraction. The hydrolytic productions and the raffinate purified by a cation exchange were evaluated using XRD and ICP-OES, respectively. The initial pH of 0.63 and Fe(II) concentration of 0.1 mol/L in the DASE, the volume ratio of organic toaqueous phase (O/A) of 3/1, and reaction temperature of 25 °C were determined as the optimal conditions. Under this conditions, Fe(II) was transformed as yellow precipitation which was characterized as α-FeOOH, and pH of raffinate was in the range of 3.6-3.8. Copyright © 2015 Elsevier B.V. All rights reserved.
Cao, Wan; Ye, Li-Hong; Cao, Jun; Xu, Jing-Jing; Peng, Li-Qing; Zhu, Qiong-Yao; Zhang, Qian-Yun; Hu, Shuai-Shuai
2015-08-07
An analytical procedure based on miniaturized solid phase extraction (SPE) and ultrahigh-performance liquid chromatography coupled with quadrupole time-of-flight tandem mass spectrometry was developed and validated for determination of six flavanones in Citrus fruits. The mesoporous molecular sieve SBA-15 as a solid sorbent was characterised by Fourier transform-infrared spectroscopy and scanning electron microscopy. Additionally, compared with reported extraction techniques, the mesoporous SBA-15 based SPE method possessed the advantages of shorter analysis time and higher sensitivity. Furthermore, considering the different nature of the tested compounds, all of the parameters, including the SBA-15 amount, solution pH, elution solvent, and the sorbent type, were investigated in detail. Under the optimum condition, the instrumental detection and quantitation limits calculated were less than 4.26 and 14.29ngmL(-1), respectively. The recoveries obtained for all the analytes were ranging from 89.22% to 103.46%. The experimental results suggested that SBA-15 was a promising material for the purification and enrichment of target flavanones from complex citrus fruit samples. Copyright © 2015 Elsevier B.V. All rights reserved.
Vichapong, Jitlada; Burakham, Rodjana; Srijaranai, Supalax
2015-07-01
A simple and fast method namely in-coupled syringe assisted octanol-water partition microextraction combined with high performance liquid chromatography (HPLC) has been developed for the extraction, preconcentration and determination of neonicotinoid insecticide residues (e.g. imidacloprid, acetamiprid, clothianidin, thiacloprid, thiamethoxam, dinotefuran, and nitenpyram) in honey. The experimental parameters affected the extraction efficiency, including kind and concentration of salt, kind of disperser solvent and its volume, kind of extraction solvent and its volume, shooting times and extraction time were investigated. The extraction process was carried out by rapid shooting of two syringes. Therefore, rapid dispersion and mass transfer processes was created between phases, and thus affects the extraction efficiency of the proposed method. The optimum extraction conditions were 10.00 mL of aqueous sample, 10% (w/v) Na2SO4, 1-octanol (100µL) as an extraction solvent, shooting 4 times and extraction time 2min. No disperser solvent and centrifugation step was necessary. Linearity was obtained within the range of 0.1-3000 ngmL(-1), with the correlation coefficients greater than 0.99. The high enrichment factor of the target analytes was 100 fold and low limit of detection (0.25-0.50 ngmL(-1)) could be obtained. This proposed method has been successfully applied in the analysis of neonicotinoid residues in honey, and good recoveries in the range of 96.93-107.70% were obtained. Copyright © 2015 Elsevier B.V. All rights reserved.
Shi, Zhihong; Li, Zhimin; Zhang, Shulan; Fu, Hongna; Zhang, Hongyi
2015-09-01
Based on the phase separation phenomenon of acetonitrile-water system at subzero temperature, a subzero-temperature liquid-liquid extraction coupled with ultra-performance liquid chromatography tandem quadrupole mass spectrometry : UPLC-MS-MS) method was developed for the simultaneous determination of 12 bioactive components in Gegen-Qinlian decoction. After optimization, the extraction conditions were set as follows: 3.0 mL of aqueous sample solution (pH 5.86) was extracted with 2 mL of acetonitrile at -35°C for 35 min. The separated acetonitrile phase was diluted 10-fold with water before UPLC-MS-MS analysis. Separation was performed on a Waters ACQUITY UPLC(®)BEH C18 column (2.1 × 100 mm i.d., 1.7 µm) with ammonium formate buffer solution (20 mmol L(-1), pH 3.2, adjusted by formic acid) and acetonitrile as mobile phase with gradient elution. Twelve target components could be separated within 10 min and quantified in multiple reaction monitoring mode, both positive and negative ionization modes were employed. Limits of detection were in the range of 0.0003-0.0451 μg mL(-1). Relative standard deviation values for intra- and interday precision were <2.71 and 8.94%, respectively. The established method provides a simple and effective framework for the quality control of Gegen-Qinlian decoction and related traditional Chinese medicinal preparations. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Zhao, Lingling; Zhong, Shuxian; Fang, Keming; Qian, Zhaosheng; Chen, Jianrong
2012-11-15
A dual-cloud point extraction (d-CPE) procedure has been developed for simultaneous pre-concentration and separation of heavy metal ions (Cd2+, Co2+, Ni2+, Pb2+, Zn2+, and Cu2+ ion) in water samples by inductively coupled plasma optical emission spectrometry (ICP-OES). The procedure is based on forming complexes of metal ion with 8-hydroxyquinoline (8-HQ) into the as-formed Triton X-114 surfactant rich phase. Instead of direct injection or analysis, the surfactant rich phase containing the complexes was treated by nitric acid, and the detected ions were back extracted again into aqueous phase at the second cloud point extraction stage, and finally determined by ICP-OES. Under the optimum conditions (pH=7.0, Triton X-114=0.05% (w/v), 8-HQ=2.0×10(-4) mol L(-1), HNO3=0.8 mol L(-1)), the detection limits for Cd2+, Co2+, Ni2+, Pb2+, Zn2+, and Cu2+ ions were 0.01, 0.04, 0.01, 0.34, 0.05, and 0.04 μg L(-1), respectively. Relative standard deviation (RSD) values for 10 replicates at 100 μg L(-1) were lower than 6.0%. The proposed method could be successfully applied to the determination of Cd2+, Co2+, Ni2+, Pb2+, Zn2+, and Cu2+ ion in water samples. Copyright © 2012 Elsevier B.V. All rights reserved.
Cerkowniak, Magdalena; Boguś, Mieczysława I; Włóka, Emilia; Stepnowski, Piotr; Gołębiowski, Marek
2018-02-01
A constant problem in veterinary medicine, human healthcare, agriculture, forestry and horticulture is the large number of pests, and the lack of effective methods to combat them which cause no harm to the rest of the environment. It is recommended and desired to reduce the use of chemicals and increase the use of agents based on knowledge acquired in the fields of biology, chemistry and agrochemicals. To learn the defense mechanisms of insects we should consider not only the site of their physiological ability to protect against external factors (cuticle), but also the possibility of chemical protection, formed by all compounds on the surface and in the body of insects. In this study, a procedure was developed to determine the esters of carboxylic acids in insect lipids. Headspace solid-phase microextraction was followed by gas chromatography coupled with gas spectrometry. First, the best conditions were selected for the analysis to obtain the best chromatographic separation. An RTx-5 column was used for this purpose. Polydimethylsiloxane/divinylbenzene (PDMS/DVB) and polyacrylate fibers were used to isolate acid esters. PDMS/DVB fiber achieved the best conditions for the extraction; the extraction time was 50 min, the extraction temperature was 105°C and the desorption time was 10 min at 230°C. These solid-phase microextraction conditions were used to analyze volatile compounds extracted from insects belonging to the Dermestidae family. Copyright © 2017 John Wiley & Sons, Ltd.
Baker, David R; Kasprzyk-Hordern, Barbara
2011-11-04
Presented is the first comprehensive study of drugs of abuse on suspended particulate matter (SPM) in wastewater. Analysis of SPM is crucial to prevent the under-reporting of the levels of analyte that may be present in wastewater. Analytical methods to date analyse the aqueous part of wastewater samples only, removing SPM through the use of filtration or centrifugation. The development of an analytical method to determine 60 compounds on SPM using a combination of pressurised liquid extraction, solid phase extraction and liquid chromatography coupled with tandem mass spectrometry (PLE-SPE-LC-MS/MS) is reported. The range of compounds monitored included stimulants, opioid and morphine derivatives, benzodiazepines, antidepressants, dissociative anaesthetics, drug precursors, and their metabolites. The method was successfully validated (parameters studied: linearity and range, recovery, accuracy, reproducibility, repeatability, matrix effects, and limits of detection and quantification). The developed methodology was applied to SPM samples collected at three wastewater treatment plants in the UK. The average proportion of analyte on SPM as opposed to in the aqueous phase was <5% for several compounds including cocaine, benzoylecgonine, MDMA, and ketamine; whereas the proportion was >10% with regard to methadone, EDDP, EMDP, BZP, fentanyl, nortramadol, norpropoxyphene, sildenafil and all antidepressants (dosulepin, amitriptyline, nortriptyline, fluoxetine and norfluoxetine). Consequently, the lack of SPM analysis in wastewater sampling protocol could lead to the under-reporting of the measured concentration of some compounds. Copyright © 2011 Elsevier B.V. All rights reserved.
Shang, Xiaohong; Zhao, Yunfeng; Zhang, Lei; Li, Xiaowei; Wu, Yongning
2011-07-01
The improvement method was developed for methylmercury determination using liquid chromatography online coupled with cold vapor atomic fluorescence spectrometry (LC-CV-AFS). Cysteine was used as complexing agent in mobile phase instead of mercaptoethanol. Under the optimized conditions, baseline separation of mercury species could be achieved within 8 min on a C18 column with a mobile phase of 5% (v/v) acetonitrile-1 g/L L-cysteine-50 mmol/L ammonium acetate aqueous solution. The linear range of calibration curve of methylmercury was 1-50 microg/L and the limit of detection (S/N = 3) for methylmercury was 0.3 microg/L. Ultrasonication assisted hydrochloric acid extraction was used to extract methylmercury from seafood samples. The sample extract was cleaned up by a C18 solid phase extraction (SPE) cartridge. For validation of the method, certified reference materials and spiked seafood samples were analyzed. The determined methylmercury contents of certified reference materials NIST1566b, BCR464 and GBW10029 agreed well with the certified values. The determined methylmercury values for Food Analysis Performance Assessment Scheme (FAPAS) sample 07115 were satisfied. The recoveries of methylmercury in seafood samples at three spiked levels (10, 50 and 500 microg/kg) ranged from 89% to 112%, including cooked seafood food. The precision of the method based on relative standard deviation (RSD) was not more than 7%. The present method of LC-CV-AFS is accurate, sensitive, simple, and can meet the demand of methylmercury determination in seafood.
Gutiérrez Valencia, Tania M; García de Llasera, Martha P
2011-09-28
A miniaturized method based on matrix solid-phase dispersion coupled to solid phase extraction and high performance liquid chromatography with diode array detection (MSPD-SPE-HPLC/DAD) was developed for the trace simultaneous determination of the following organophosphorus pesticides (OPPs) in bovine tissue: parathion-methyl, fenitrothion, parathion, chlorfenvinphos, diazinon, ethion, fenchlorphos, chlorpyrifos and carbophenothion. To perform the coupling between MSPD and SPE, 0.05 g of sample was dispersed with 0.2 g of C(18) silica sorbent and packed into a stainless steel cartridge containing 0.05 g of silica gel in the bottom. After a clean-up of high and medium polarity interferences with water and an acetonitrile:water mixture, the OPPs were desorbed from the MSPD cartridge with pure acetonitrile and directly transferred to a dynamic mixing chamber for dilution with water and preconcentration into an SPE 20 mm × 2.0 mm I.D. C(18) silica column. Subsequently, the OPPs were eluted on-line with the chromatographic mobile phase to the analytical column and the diode array detector for their separation and detection, respectively. The method was validated and yielded recovery values between 91% and 101% and precision values, expressed as relative standard deviations (RSD), which were less than or equal to 12%. Linearity was good and ranged from 0.5 to 10 μg g(-1), and the limits of detection of the OPPs were in the range of 0.04-0.25 μg g(-1). The method was satisfactorily applied to the analysis of real samples and is recommended for food control, research efforts when sample amounts are limited, and laboratories that have ordinary chromatographic instrumentation. Copyright © 2011 Elsevier B.V. All rights reserved.
Lian, Ziru; Wang, Jiangtao
2017-09-15
Gonyautoxins 1,4 (GTX1,4) from Alexandrium minutum samples were isolated selectively and recognized specifically by an innovative and effective extraction procedure based on molecular imprinting technology. Novel molecularly imprinted polymer microspheres (MIPMs) were prepared by double-templated imprinting strategy using caffeine and pentoxifylline as dummy templates. The synthesized polymers displayed good affinity to GTX1,4 and were applied as sorbents. Further, an off-line molecularly imprinted solid-phase extraction (MISPE) protocol was optimized and an effective approach based on the MISPE coupled with HPLC-FLD was developed for selective isolation of GTX1,4 from the cultured A. minutum samples. The separation method showed good extraction efficiency (73.2-81.5%) for GTX1,4 and efficient removal of interferences matrices was also achieved after the MISPE process for the microalgal samples. The outcome demonstrated the superiority and great potential of the MISPE procedure for direct separation of GTX1,4 from marine microalgal extracts. Copyright © 2017. Published by Elsevier Ltd.
Song, Xuqin; Zhou, Tong; Liu, Qingying; Zhang, Meiyu; Meng, Chenying; Li, Jiufeng; He, Limin
2016-10-01
A simple and sensitive method based on molecularly imprinted solid-phase extraction coupled with liquid chromatography-tandem mass spectrometry was developed for the determination of the residues of ten macrolide drugs in swine, cattle and chicken muscles samples. The molecularly imprinted polymers (MIPs) were synthesized using tylosin as a template and methacrylic acid as a functional monomer. Samples were extracted with sodium borate buffer solution and ethyl acetate, and purified by the MIP cartridge. The results showed that the cartridge exhibited good recognition performance for macrolides, and better purification effect than the traditional solid-phase extraction cartridges. Recoveries of analytes at three spiking levels 1, 5 and 20μgkg(-1) ranged from 60.7% to 100.3% with the relative standard deviations less than 14%. The limits of detection of the method were between 0.1 and 0.4μgkg(-1). The method is useful for the routine monitoring of the residues of macrolide drugs in animal muscles. Copyright © 2016 Elsevier Ltd. All rights reserved.
Han, Yehong; Yang, Chunliu; Zhou, Yang; Han, Dandan; Yan, Hongyuan
2017-03-01
A new method involving ionic liquid-hybrid molecularly imprinted material-filter solid-phase extraction coupled to high-performance liquid chromatography (IL-HIM-FSPE-HPLC) was developed for the simultaneous isolation and determination of 6-benzyladenine (6-BA) and 4-chlorophenoxyacetic acid (4-CPA) in bean sprouts. Sample preconcentration was performed using a modified filter, with the new IL-HIM as the adsorbent, which shows double adsorption. The first adsorption involves special recognition of molecular imprinting, and the second involves ion exchange and electrostatic attraction caused by the ionic liquid. This method combines the advantages of ionic liquids, hybrid materials, and molecularly imprinted polymers and was successfully applied to determine 6-BA and 4-CPA in bean sprouts. The adsorption of 6-BA to IL-HIM is based on selective imprinted recognition, whereas the adsorption of 4-CPA is mainly dependent on ion-exchange interactions.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zheng, Xueyun; Wojcik, Roza; Zhang, Xing
Ion mobility spectrometry (IMS) is a widely used analytical technique for rapid molecular separations in the gas phase. IMS alone is useful, but its coupling with mass spectrometry (MS) and front-end separations has been extremely beneficial for increasing measurement sensitivity, peak capacity of complex mixtures, and the scope of molecular information in biological and environmental sample analyses. Multiple studies in disease screening and environmental evaluations have even shown these IMS-based multidimensional separations extract information not possible with each technique individually. This review highlights 3-dimensional separations using IMS-MS in conjunction with a range of front-end techniques, such as gas chromatography (GC),more » supercritical fluid chromatography (SFC), liquid chromatography (LC), solid phase extractions (SPE), capillary electrophoresis (CE), field asymmetric ion mobility spectrometry (FAIMS), and microfluidic devices. The origination, current state, various applications, and future capabilities for these multidimensional approaches are described to provide insight into the utility and potential of each technique.« less
Zheng, Xueyun; Wojcik, Roza; Zhang, Xing; Ibrahim, Yehia M.; Burnum-Johnson, Kristin E.; Orton, Daniel J.; Monroe, Matthew E.; Moore, Ronald J.; Smith, Richard D.; Baker, Erin S.
2017-01-01
Ion mobility spectrometry (IMS) is a widely used analytical technique for rapid molecular separations in the gas phase. Though IMS alone is useful, its coupling with mass spectrometry (MS) and front-end separations is extremely beneficial for increasing measurement sensitivity, peak capacity of complex mixtures, and the scope of molecular information available from biological and environmental sample analyses. In fact, multiple disease screening and environmental evaluations have illustrated that the IMS-based multidimensional separations extract information that cannot be acquired with each technique individually. This review highlights three-dimensional separations using IMS-MS in conjunction with a range of front-end techniques, such as gas chromatography, supercritical fluid chromatography, liquid chromatography, solid-phase extractions, capillary electrophoresis, field asymmetric ion mobility spectrometry, and microfluidic devices. The origination, current state, various applications, and future capabilities of these multidimensional approaches are described in detail to provide insight into their uses and benefits. PMID:28301728
Savareear, Benjamin; Lizak, Radoslaw; Brokl, Michał; Wright, Chris; Liu, Chuan; Focant, Jean-Francois
2017-10-20
A method involving headspace solid-phase microextraction (HS-SPME) and comprehensive two-dimensional gas chromatography coupled to time-of-flight mass spectrometry (GC×GC-TOFMS) was developed and optimised to elucidate the volatile composition of the particulate phase fraction of aerosol produced by tobacco heating products (THPs). Three SPME fiber types were studied in terms of extraction capacity and precision measurements. Divinylbenzene polydimethylsiloxane appeared as the most efficient coating for these measurements. A central composite design of experiment was utilised for the optimization of the extraction conditions. Qualitative and semi-quantitative analysis of the headspace above THP aerosol condensate was carried out using optimised extraction conditions. Semi-quantitative analyses of detected constituents were performed by assuming that their relative response factors to the closest internal standard ( i t R ) were equal to 1. Using deconvoluted mass spectral data (library similarity and reverse match >750) and linear retention indices (match window of ±15 index units), 205 peaks were assigned to individual compounds, 82 of which (including 43 substances previously reported to be present in tobacco) have not been reported previously in tobacco aerosol. The major volatile fraction of the headspace contained ketones, alcohols, aldehydes, alicyclic hydrocarbons alkenes, and alkanes. The method was further applied to compare the volatiles from the particulate phase of aerosol composition of THP with that of reference cigarette smoke and showed that the THP produced a less complex chemical mixture. This new method showed good efficiency and precision for the peak areas and peak numbers from the volatile fraction of aerosol particulate phase for both THP and reference cigarettes. Copyright © 2017 Elsevier B.V. All rights reserved.
Yin, Yuli; Yan, Liang; Zhang, Zhaohui; Wang, Jing; Luo, Ningjing
2016-04-01
We describe novel cinnamic acid polydopamine-coated magnetic imprinted polymers for the simultaneous selective extraction of cinnamic acid, ferulic acid and caffeic acid from radix scrophulariae sample. The novel magnetic imprinted polymers were synthesized by surface imprinting polymerization using magnetic multi-walled carbon nanotubes as the support material, cinnamic acid as the template and dopamine as the functional monomer. The magnetic imprinted polymers were characterized by transmission electron microscopy, scanning electron microscopy, Fourier transform infrared spectroscopy and vibrating sample magnetometry. The results revealed that the magnetic imprinted polymers had outstanding magnetic properties, high adsorption capacity, selectivity and fast kinetic binding toward cinnamic acid, ferulic acid and caffeic acid. Coupled with high-performance liquid chromatography, the extraction conditions of the magnetic imprinted polymers as a magnetic solid-phase extraction sorbent were investigated in detail. The proposed imprinted magnetic solid phase extraction procedure has been used for the purification and enrichment of cinnamic acid, ferulic acid and caffeic acid successfully from radix scrophulariae extraction sample with recoveries of 92.4-115.0% for cinnamic acid, 89.4-103.0% for ferulic acid and 86.6-96.0% for caffeic acid. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
He, Kang-Hao; Zou, Xiao-Li; Liu, Xiang; Zeng, Hong-Yan
2012-01-01
A method using reversed phase high performance liquid chromatography (RP-HPLC) coupled with diode array detector (DAD) was developed for the simultaneous determination of canthaxanthin and astaxanthin in egg yolks. Samples were extracted with acetonitrile in ultrasonic bath for 20 minutes and then purified by freezing-lipid filtration and solid phase extraction (SPE). After being vaporized to dryness by nitrogen blowing and made up to volume with methanol, the extract solution was chromatographically separated in C18 column with a unitary mobile phase consisting of acetonitrile. The proposed method was validated in terms of linearity, precision, accuracy, and limit of detection (LOD). Regression analysis revealed a good linearity between peak area of each analyte and its concentration (r > or = 0.998). The intra- and inter-day relative standard deviations (RSDs) were less than 3.6% and 5.2%, respectively. LODs of canthaxanthin and astaxanthin were 0.035 and 0.027 microg/mL (S/N = 3). The average recoveries of canthaxanthin and astaxanthin were 91.5% and 88.7%. The proposed method is simple, fast and easy to apply.
Fang, Yong; Pan, Yushi; Li, Peng; Xue, Mei; Pei, Fei; Yang, Wenjian; Ma, Ning; Hu, Qiuhui
2016-12-15
An analytical method using reversed phase chromatography-inductively coupled plasma mass spectrometry for arsenic and mercury speciation analysis was described. The effect of ion-pairing reagent on simultaneous separation of four arsenic (arsenite, arsenate, monomethlyarsonate and dimethylarsinate) and three mercury species (inorganic mercury (Hg(II)), methylmecury and ethylmercury) was investigated. Parameters including concentrations and pH of the mobile phase were optimized. The separation and re-equilibration time was attained within 20min. Meanwhile, a sequential extraction method for arsenic and mercury in rice was tested. Subsequently, 1% HNO3 microwave-assisted extraction was chosen. Calibration curves based on peak area measurements were linear with correlation coefficient greater than 0.9958 for each species in the range studied. The detection limits of the species were in the range of 0.84-2.41μg/L for arsenic and 0.01-0.04μg/L for mercury, respectively. The proposed method was then successfully applied for the simultaneous determination of arsenic and mercury species in rice flour standard material and two kinds of rice from local markets. Copyright © 2016 Elsevier Ltd. All rights reserved.
Lintelmann, Jutta; Wu, Xiao; Kuhn, Evelyn; Ritter, Sebastian; Schmidt, Claudia; Zimmermann, Ralf
2018-05-01
A high-performance liquid chromatographic (HPLC) method with integrated solid-phase extraction for the determination of 1-hydroxypyrene and 1-, 2-, 3-, 4- and 9-hydroxyphenanthrene in urine was developed and validated. After enzymatic treatment and centrifugation of 500 μL urine, 100 μL of the sample was directly injected into the HPLC system. Integrated solid-phase extraction was performed on a selective, copper phthalocyanine modified packing material. Subsequent chromatographic separation was achieved on a pentafluorophenyl core-shell column using a methanol gradient. For quantification, time-programmed fluorescence detection was used. Matrix-dependent recoveries were between 94.8 and 102.4%, repeatability and reproducibility ranged from 2.2 to 17.9% and detection limits lay between 2.6 and 13.6 ng/L urine. A set of 16 samples from normally exposed adults was analyzed using this HPLC-fluorescence detection method. Results were comparable with those reported in other studies. The chromatographic separation of the method was transferred to an ultra-high-performance liquid chromatography pentafluorophenyl core-shell column and coupled to a high-resolution time-of-flight mass spectrometer (HR-TOF-MS). The resulting method was used to demonstrate the applicability of LC-HR-TOF-MS for simultaneous target and suspect screening of monohydroxylated polycyclic aromatic hydrocarbons in extracts of urine and particulate matter. Copyright © 2018 John Wiley & Sons, Ltd.
Viñas, Pilar; Campillo, Natalia; Hernández-Pérez, Mónica; Hernández-Córdoba, Manuel
2008-03-17
A comparison of direct immersion solid-phase microextraction (DI-SPME) and stir bar sorptive extraction (SBSE) coupled to liquid chromatography (HPLC) with fluorimetric detection for the rapid analysis of resveratrol isomers is described. For DI-SPME, a polar Carbowax-template resin (CW/TPR) 50mum fiber was the most efficient and optimum extraction conditions were 40 degrees C and an extraction time of 30min, stirring in the presence of 5% (m/v) sodium chloride and 0.07M acetate/acetic acid buffer (pH 6). Desorption was carried out using the static mode for 10min. Linearity was obtained in the 5-150 and 2-150ngmL(-1) ranges for trans- and cis-resveratrol, with detection limits of 2 and 0.5ngmL(-1), respectively. When using SBSE, a polydimethylsiloxane (PDMS) twister provided best extraction by means of a derivatization reaction in the presence of acetic anhydride and potassium carbonate. The same time and temperature were used for the extraction step in the presence of 2.5% (m/v) sodium chloride, and liquid desorption was performed with 150microL of a 50/50 (v/v) acetonitrile/1% (v/v) acetic acid solution in a desorption time of 15min. Linearity was now between 0.5 and 50ngmL(-1) for trans-resveratrol with a detection limit of 0.1ngmL(-1), while cis-resveratrol could not be extracted. The proposed methods were successfully applied to determining the resveratrol isomer content of wine, must and fruit juices.
Yuan, Zhiquan; Xiao, Xiaohua; Li, Gongke
2013-11-22
A simple and efficient dynamic pH junction high-speed counter-current chromatography method was developed and further applied to the online extraction, separation and purification of alkaloids from Stephania cepharantha by coupling with microwave-assisted extraction. Mineral acid and organic base were added into the mobile phase and the sample solution, respectively, leading to the formation of a dynamic pH junction in the column and causing focus of alkaloids. Selective focus of analytes can be achieved on the basis of velocity changes of the pH junction through appropriate selection of solvent systems and optimization of additive concentrations. The extract can be directly introduced into the HSCCC for the online extraction, separation and purification of alkaloids from S. cepharantha. Continuous separation can be easily achieved with the same solvent system. Under the optimum conditions, 6.0 g original sample was extracted with 60 mL of the upper phase of hexane-ethyl acetate-methanol-water (1:1:1:1, v/v/v/v) containing 10% triethylamine under 50 °C and 400 W irradiation power for 10 min, the extracts were directly separated and purified by high-speed counter-current chromatography. A total of 5.7 mg sinomenine, 8.3mg 6,7-di-O-acetylsinococuline, 17.9 mg berbamine, 12.7 mg isotetrandrine and 14.6 mg cepharanthine were obtained with purities of 96.7%, 93.7%, 98.7%, 97.3% and 99.3%, respectively. The online method provides good selectivity to ionizable compounds and improves the separation and purification efficiency of the high-speed counter-current chromatography technique. It has good potential for separation and purification of effective compounds from natural products. Copyright © 2013 Elsevier B.V. All rights reserved.
Rao, Wei; Cai, Rong; Yin, Yuli; Long, Fang; Zhang, Zhaohui
2014-10-01
In this paper, a highly selective sample clean-up procedure combining magnetic dummy molecular imprinting with solid-phase extraction was developed for rapid separation and determination of 4-nonylphenol (NP) in the environmental water samples. The magnetic dummy molecularly imprinted polymers (mag-DMIPs) based on multi-walled carbon nanotubes were successfully synthesized with a surface molecular imprinting technique using 4-tert-octylphenol as the dummy template and tetraethylorthosilicate as the cross-linker. The maximum adsorption capacity of the mag-DMIPs for NP was 52.4 mg g(-1) and it took about 20 min to achieve the adsorption equilibrium. The mag-DMIPs exhibited the specific selective adsorption toward NP. Coupled with high performance liquid chromatography analysis, the mag-DMIPs were used to extract solid-phase and detect NP in real water samples successfully with the recoveries of 88.6-98.1%. Copyright © 2014 Elsevier B.V. All rights reserved.
Pan, Ru; Shao, Dejia; Qi, Xueyong; Wu, Yun; Fu, Wenyan; Ge, Yanru; Fu, Haizhen
2013-01-01
The effective method of ionic liquid-based aqueous two-phase extraction, which involves ionic liquid (IL) (1-butyl-3-methyllimidazolium chloride, [C4mim]Cl) and inorganic salt (K2HPO4) coupled with high-performance liquid chromatography (HPLC), has been used to extract trace tilmicosin in real water samples which were passed through a 0.45 μm filter. The effects of the different types of salts, the concentration of K2HPO4 and of ILs, the pH value and temperature of the systems on the extraction efficiencies have all been investigated. Under the optimum conditions, the average extraction efficiency is up to 95.8%. This method was feasible when applied to the analysis of tilmicosin in real water samples within the range 0.5-40 μg mL(-1). The limit of detection was found to be 0.05 μg mL(-1). The recovery rate of tilmicosin was 92.0-99.0% from the real water samples by the proposed method. This process is suggested to have important applications for the extraction of tilmicosin.
Ding, Linlin; Wang, Yanji; Wu, Zhaoliang; Liu, Wei; Li, Rui; Wang, Yanyan
2016-10-02
A novel technology coupling extraction and foam fractionation was developed for separating the total saponins from Achyranthes bidentata. In the developed technology, the powder of A. bidentata was loaded in a nylon filter cloth pocket with bore diameter of 180 µm. The pocket was fixed in the bulk liquid phase for continuously releasing saponins. Under the optimal conditions, the concentration and the extraction rate of the total saponins in the foamate by the developed technology were 73.5% and 416.2% higher than those by the traditional technology, respectively. The foamates obtained by the traditional technology and the developed technology were analyzed by ultraperformance liquid chromatography-mass spectrometry to determine their ingredients, and the results appeared that the developed technology exhibited a better performance for separating saponins than the traditional technology. The study is expected to develop a novel technology for cost effectively separating plant-derived materials with surface activity.
Tess, D A; Cole, R O; Toler, S M
1995-12-15
A simple and highly sensitive reversed-phase fluorimetric HPLC method for the quantitation of droloxifene from rat, monkey, and human plasma as well as human serum is described. This assay employs solid-phase extraction and has a dynamic range of 25 to 10,000 pg/ml. Sample extraction (efficiencies > 86%) was accomplished using a benzenesulfonic acid (SCX) column with water and methanol rinses. Droloxifene and internal standard were eluted with 1 ml of 3.5% (v/v) ammonium hydroxide (30%) in methanol. Samples were quantitated using post-column UV-photochemical cyclization coupled with fluorimetric detection with excitation and emission wavelengths of 260 nm and 375 nm, respectively. Relative ease of sample extraction and short run times allow for the analysis of approximately 100 samples per day.
Liu, He; Zhang, Yupu; Sun, Yantao; Wang, Xue; Zhai, Yujuan; Sun, Ye; Sun, Shuo; Yu, Aimin; Zhang, Hanqi; Wang, Yinghua
2010-10-15
The arctiin and arctigenin in the fruit of Arctium lappa L. were extracted by matrix solid-phase dispersion (MSPD) and determined by high-performance liquid chromatography (HPLC) with fluorescence detection. The experimental conditions for the MSPD were optimized. Silica gel was selected as dispersion adsorbent and methanol as elution solvent. The calibration curve showed good relationship (r>0.9998) in the concentration range of 0.010-5.0μgmL(-1) for arctiin and 0.025-7.5μgmL(-1) for arctigenin. The recoveries were between 74.4% and 100%. The proposed method consumed less sample, time and solvent compared with conventional methods, including ultrasonic and Soxhlet extraction. Copyright © 2010 Elsevier B.V. All rights reserved.
Investigation of High Linearity DFB Lasers for Analog Communications
1998-02-01
personal communication systems (PCS) service and phased array radar. In this thesis, we examine the dynamic range and distortion for a Fujitsu DFB laser. We...PCS) service and phased array radar. In this thesis, we examine the dynamic range and distortion for a Fujitsu DFB laser. We extract parameters from...is dependent upon the coupling coefficient, as discussed in Chapter 3. Spatial hole burning is more important at lower frequencies (owing to finite
Jiang, Wenhui; Shan, Hu; Song, Jiying; Lü, Haitao
2017-01-01
A rapid and efficient method for the separation and purification of ombuoside from Gynostemma pentaphyllum by microwave-assisted extraction coupled with high-speed counter-current chromatography (HSCCC) was successfully developed. Using an orthogonal array design L 9 (3 4 ), the extraction conditions, including microwave power, irradiation time, solid-to-liquid ratio and extraction times, were optimized. Ombuoside was isolated and purified from the crude extraction by HSCCC with two-phase solvent system composed of n-hexane:ethyl acetate:ethanol:water (5:6:5:5, v/v) in a single run. A 210 mg quantity of the crude extract containing 2.16% ombuoside was loaded, yielding 3.9 mg of ombuoside at 96.7% purity. The chemical structure of ombuoside was determined by comparison with the high-performance liquid chromatography retention time of standard substance as well as UV, FT-IR, ESI-MS, 1 H NMR and 13 C NMR spectra. The purified ombuoside had strong 1,1-diphenyl-2-picrylhydrazyl and hydroxyl free radical scavenging activities. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Sarafraz-Yazdi, A; Mofazzeli, F; Es'haghi, Z
2009-07-15
A new and fast hollow fiber based liquid phase microextraction (HF-LPME) method using volatile organic solvents coupled with high-performance liquid chromatography (HPLC) was developed for determination of aromatic amines in the environmental water samples. Analytes including 3-nitroaniline, 3-chloroaniline and 4-bromoaniline were extracted from 6 mL basic aqueous sample solution (donor phase, NaOH 1 mol L(-1)) into the thin film of organic solvent that surrounded and impregnated the pores of the polypropylene hollow fiber wall (toluene, 20 microL), then back-extracted into the 6 mL acidified aqueous solution (acceptor phase, HCl 0.5 mol L(-1)) in the lumen of the two-end sealed hollow fiber. After the extraction, 5 microL of the acceptor phase was withdrawn into the syringe and injected directly into the HPLC system for the analysis. The parameters influencing the extraction efficiency including the kind of organic solvent and its volume, composition of donor and acceptor phases and the volume ratio between them, extraction time, stirring rate, salt addition and the effect of the analyte complexation with 18-crown-6 ether were investigated and optimized. Under the optimal conditions (donor phase: 6 mL of 1 mol L(-1) NaOH with 10% NaCl; organic phase: 20 microL of toluene; acceptor phase: 6 microL of 0.5 mol L(-1) HCl and 600 mmol L(-1) 18-crown-6 ether; pre-extraction and back-extraction times: 75 s and 10 min, respectively; stirring rate: 800 rpm), the obtained EFs were between 259 and 674, dynamic linear ranges were 0.1-1000 microg L(-1) (R>0.9991), and also the limits of detection were in the range of 0.01-0.1 micro gL(-1). The proposed procedure worked very well for real environmental water samples with microgram per liter level of the analytes, and good relative recoveries (91-102%) were obtained for the spiked sample solutions.
Development of Electrospun Nanomaterials and their Applications in Separation Science
NASA Astrophysics Data System (ADS)
Newsome, Toni Elwell
In separations, efficiency is inversely related to the diameter of the sorbent particles of the stationary phase. Thus, materials research in separation science has primarily been directed towards reducing the diameter of the sorbent particle used in the stationary phase. In this dissertation, innovative methods designed for the fabrication and application of electrospun sorbent nanomaterials for separation science are described. Electrospinning is a facile, cost-effective technique that relies on repulsive electrostatic forces to produce nanofibers from a viscoelastic solution. Here, electrospinning is used to generate polymer, carbon, and silica-based nanofibers which are employed as sorbent nanomaterials in extractions and separations. Electrospun carbon nanofibers have proven to be ideal extractive phases for solid-phase microextraction (SPME) when coupled to gas chromatography (GC) for headspace sampling of volatile analytes. Herein, these carbon nanofibers were employed in the direct extraction of nonvolatile analytes and coupled to liquid chromatography (LC) for the first time. The high surface area of the coatings led to enhanced extraction efficiencies; they offered a 3-33 fold increase in efficiency relative to a commercial SPME phase. Carbon nanofibers proved to be stable when immersed in liquids common to LC demonstrating the enhanced stability of these coatings in SPME coupled to LC relative to conventional SPME fibers. The enhanced chemical and mechanical stability of the carbon SPME coatings considerably expanded the range of compounds applicable to SPME and extended the lifetimes of the fibers. Electrospun nanofibers have also proven to be ideal stationary phases in ultra-thin layer chromatography (UTLC). Nanofibers provide faster separations and enhanced separation efficiencies compared to commercial particle-based stationary phases in a relatively short distance. Here, the electrospun-UTLC technology was extended for the first time to nanofibers composed of silica, the most commonly used surface for TLC. An electrospinning method was optimized to produce silica-based nanofibers with the smallest diameter possible (300-380 nm) while maintaining homogenous nanofiber morphology. Highly efficient separations were performed in 15 mm with observed plate heights as low as 8.6 mum. Silica-based nanofibers proved to be chemically stable with a wide variety of TLC reagents demonstrating the enhanced compatibility of these phases with common TLC methods relative to polymer and carbon nanofiber UTLC plates. The extension of electrospun UTLC to silica-based nanofibers vastly expanded the range of analytes and TLC methods which can be used with this technology. The main disadvantage of conventional TLC development methods is that the mobile phase velocity decreases with increasing separation distance. Here, the chromatographic performance of electrospun polymer stationary phases was further improved by using a forced-flow mobile phase in planar electrochromatography (PEC) in which mobile phase velocity does not diminish with increasing distance. Separations were performed on polymer nanofiber UTLC plates in 1-2 min. Compared to UTLC, PEC offered unique selectivity, decreased analysis times (> 4 times faster), and enhanced efficiency (2-3 times lower plate height). In addition, two-dimensional (2D) separations of a complex analyte mixture using UTLC followed by PEC required only 11 min and exhibited a significant increase in separation number (70-77).
Praveen, Prashant; Loh, Kai-Chee
2015-12-01
A two-phase partitioning membrane bioreactor (TPPMB) was designed and operated for treatment of high strength phenolic wastewater through extraction/stripping and concomitant biodegradation. Tributyl phosphate dissolved in kerosene was used as the organic phase, sodium hydroxide as the stripping phase and Pseudomonas putida for biodegradation. In a semi-dispersive approach, organic phase dispersed in the stripping solution was contacted with wastewater through semi-permeable membranes for removal of phenol from wastewater, while the microorganisms were inoculated directly into the wastewater for biodegradation. The TPPMB exhibited high phenol removal rates, and phenol concentrations of 1000-3000mg/L were reduced to undetected amounts within 2-4h. Up to 80% phenol was recovered through extraction, while the remaining was metabolized by the microorganisms. Phenol recovery in the TPPMB was enhanced by increasing the mass transfer rate of phenol through the membranes, and it was also estimated that phenol diffusion through the aqueous boundary layer on the tube side was the rate limiting step. The flexibility in adjusting inoculation time in the TPPMB prevented microorganisms from adverse effects of substrate inhibition, which facilitated complete removal of phenol from the wastewater. TPPMB retained the advantages of both solvent extraction and biodegradation, and it can be highly promising for the treatment of toxic industrial wastewater. Copyright © 2015 Elsevier Ltd. All rights reserved.
Davarani, Saied Saeed Hosseiny; Nojavan, Saeed; Asadi, Roghayeh; Banitaba, Mohammad Hossein
2013-07-01
In this study, a platinum wire coated with poly(3,4-ethylenedioxythiophen) was used as an electro-assisted solid-phase microextraction fiber for the quantification of tricyclic antidepressant drugs in biological samples by coupling to GC employing a flame ionization detector. In this study, an electric field increased the extraction rate and recovery. The fiber used as a solid phase was synthesized by the electropolymerization of 3,4-ethylenedioxythiophen monomers onto a platinum wire. The ability of this fiber to extract imipramine, desipramine, and clomipramine by using the electro-assisted solid-phase microextraction technique was evaluated. The effect of various parameters that influence the extraction efficiency, which include solution temperature, extraction time, stirring rate, ionic strength, time and temperature of desorption, and thickness of the fiber, was optimized. Under optimized conditions, the linear ranges and regression coefficients of calibration curves were in the range of 0.5-250 and 0.990-0.998 ng/mL, respectively. Detection limits were in the range of 0.15-0.45 ng/mL. Finally, this method was applied to the determination of drugs in urine and wastewater samples and recoveries were 4.8-108.9%. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Oliveira, Éder Costa; Echegoyen, Yolanda; Cruz, Sandra Andrea; Nerin, Cristina
2014-09-01
Hollow fiber liquid phase microextraction (HFLPME) and solid phase microextraction (SPME) methods for pre-concentration of contaminants (toluene, benzophenone, tetracosane and chloroform) in food simulants were investigated. For HFLPME 1-heptanol, 2-octanone and dibutyl-ether were studied as extracting solvents. Analysis by gas chromatography coupled to mass spectrometry (GC-MS), flame ionization (GC-FID) and electron capture detectors (GC-ECD) were carried out. In addition, the methods were employed to evaluate the safety in use of a PET material after the recycling process (comprising washing, extrusion and solid state polymerization (SSP)) through extractability studies of the contaminants using 10% (v/v) ethanol in deionized water and 3% (w/v) acetic acid in deionized water as food simulants in different conditions: 10 days at 40°C and 2h at 70°C. The HFLPME preconcentration method provided increased sensitivity when compared to the SPME method and allowed to analyze concentration levels below 10 µg surrogate per kg food simulant. The results of the extractability studies showed considerable reductions after the extrusion and SSP processes and indicated the compliance with regulations for using recycled PET in contact with food. Copyright © 2014 Elsevier B.V. All rights reserved.
Zhen, Qi; Zhang, Min; Song, Wenlan; Wang, Huiju; Wang, Xuemei; Du, Xinzhen
2016-10-01
An oriented titanium-nickel oxide composite nanotubes coating was in situ grown on a nitinol wire by direct electrochemical anodization in ethylene glycol with ammonium fluoride and water for the first time. The morphology and composition of the resulting coating showed that the anodized nitinol wire provided a titania-rich coating. The titanium-nickel oxide composite nanotubes coated fiber was used for solid-phase microextraction of different aromatic compounds coupled to high-performance liquid chromatography with UV detection. The titanium-nickel oxide composite nanotubes coating exhibited high extraction capability, good selectivity, and rapid mass transfer for weakly polar UV filters. Thereafter the important parameters affecting extraction efficiency were investigated for solid-phase microextraction of UV filters. Under the optimized conditions, the calibration curves were linear in the range of 0.1-300 μg/L for target UV filters with limits of detection of 0.019-0.082 μg/L. The intraday and interday precision of the proposed method with the single fiber were 5.3-7.2 and 5.9-7.9%, respectively, and the fiber-to-fiber reproducibility ranged from 6.3 to 8.9% for four fibers fabricated in different batches. Finally, its applicability was evaluated by the extraction and determination of target UV filters in environmental water samples. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Romarís-Hortas, Vanessa; Bermejo-Barrera, Pilar; Moreda-Piñeiro, Antonio
2012-05-04
Anion exchange high performance liquid chromatography hyphenated with inductively coupled plasma-mass spectrometry has been novelly applied to assess inorganic (iodide and iodate) and organic (3-iodotyrosine - MIT, and 3,5-diiodotyrosine - DIT) iodine species in a single chromatographic run. The optimized operating conditions (Dionex IonPac AS7, gradient elution with 175 mM ammonium nitrate plus 15% (v/v) methanol, pH 3.8, as a mobile phase and flow rates within the 0.5-1.5 mL min(-1) range) have also been used to perform inorganic bromine speciation analysis (bromide and bromate). The developed method has been applied for determining the bio-available contents of iodine and bromine species in dialyzates from edible seaweed. Reverse phase high performance liquid chromatography (Zorbax Eclipse XDB-C8, gradient elution with 0.2% (m/m) acetic acid, and 0.2% (m/m) acetic acid in methanol, as mobile phases, and a constant flow rate of 0.75 mL min(-1)) also hyphenated with inductively coupled plasma-mass spectrometry was used to confirm the presence of organic iodine species (MIT and DIT) in the dialyzates. The verification of the presence of iodinated amino acids (MIT and DIT) in the extracts was also performed by reverse phase high performance liquid chromatography-electrospray ionization-mass spectrometry (LTQ Orbitrap). The developed methods have provided good repeatability (RSD values lower than 10% for both anion exchange and reverse phase separations) and analytical recoveries within the 90-105% range for all cases. The in vitro bio-availability method consisted of a simulated gastric and an intestinal digestion/dialysis (10 kDa molecular weight cut-off - MWCO) two-stage procedure. Iodide and MIT were the main bio-available species quantified, whereas bromide was the major bromine species found in the extracts. Copyright © 2012 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Chen, Shizhong; Zhu, Shengping; Lu, Dengbo
2018-01-01
A method was developed for speciation analysis of antimony by electrothermal vaporization inductively coupled plasma mass spectrometry (ETV-ICP-MS) after preconcentration/separation using dispersive micro-solid phase extraction (DMSPE) and dispersive liquid-liquid micro-extraction (DLLME). In DMSPE, titanium dioxide nanofibers were used for preconcentration and separation of analytes. The upper aqueous phase and elution solution from DMSPE were used for further preconcentration and separation of Sb(III) and Sb(V) by DLLME without any pre-oxidation or pre-reduction operation, respectively. The extracts from DLLME were used for ETV-ICP-MS determination with APDC as a chemical modifier. Under optimal conditions, the detection limits of this method were 0.019 and 0.025 pg mL- 1 with relative standard deviations of 5.7% and 6.9% for Sb(III) and Sb(V) (c = 1.0 ng mL- 1, n = 9), respectively. This method was applied for speciation analysis of Sb and its distribution in the tea leaves and the tea infusion, including total, suspended, soluble, organic and inorganic Sb as well as Sb(III) and Sb(V). The results showed that the contents of Sb are 62.7, 12.9 and 47.3 ng g- 1 in the tea leaves, tea residue and tea soup, respectively; those of soluble, organic, inorganic, Sb(III) and Sb(V) are 0.41, 0.11, 0.29, 0.21 and 0.07 ng mL- 1 in the tea soup, respectively. A certified reference material of tea leaves (GBW 07605) was analyzed by this method with satisfactory results.
Aga, D.S.; Thurman, E.M.
1993-01-01
Solid-phase extraction (SPE) and enzyme-linked immunosorbent assay (ELISA) were coupled for automated trace analysis of pristine water samples containing 2-chloro-4-ethylamino-6-isopropylamine-s-triazine (atrazine) and 2-chloro-2???,6???-diethyl-N-(methoxymethyl)acetanilide (alachlor). The isolation of the two herbicides on a C18-resin involved the selection of an elution solvent that both removes interfering substances and is compatible with ELISA. Ethyl acetate was selected as the elution solvent followed by a solvent exchange with methanol/water (20/80, % v/v). The SPE-ELISA method has a detection limit of 5.0 ng/L (5 ppt), >90% recovery, and a relative standard deviation of ??10%. The performance of a microtiter plate-based ELISA and a magnetic particle-based ELISA coupled to SPE was also evaluated. Although the sensitivity of the two ELISA methods was comparable, the precision using magnetic particles was improved considerably (??10% versus ??20%) because of the faster reaction kinetics provided by the magnetic particles. Finally, SPE-ELISA and isotope dilution gas chromatography/ mass spectrometry correlated well (correlation coefficient of 0.96) for lake-water samples. The SPE-ELISA method is simple and may have broader applications for the inexpensive automated analysis of other contaminants in water at trace levels.
A robust approach for ECG-based analysis of cardiopulmonary coupling.
Zheng, Jiewen; Wang, Weidong; Zhang, Zhengbo; Wu, Dalei; Wu, Hao; Peng, Chung-Kang
2016-07-01
Deriving respiratory signal from a surface electrocardiogram (ECG) measurement has advantage of simultaneously monitoring of cardiac and respiratory activities. ECG-based cardiopulmonary coupling (CPC) analysis estimated by heart period variability and ECG-derived respiration (EDR) shows promising applications in medical field. The aim of this paper is to provide a quantitative analysis of the ECG-based CPC, and further improve its performance. Two conventional strategies were tested to obtain EDR signal: R-S wave amplitude and area of the QRS complex. An adaptive filter was utilized to extract the common component of inter-beat interval (RRI) and EDR, generating enhanced versions of EDR signal. CPC is assessed through probing the nonlinear phase interactions between RRI series and respiratory signal. Respiratory oscillations presented in both RRI series and respiratory signals were extracted by ensemble empirical mode decomposition for coupling analysis via phase synchronization index. The results demonstrated that CPC estimated from conventional EDR series exhibits constant and proportional biases, while that estimated from enhanced EDR series is more reliable. Adaptive filtering can improve the accuracy of the ECG-based CPC estimation significantly and achieve robust CPC analysis. The improved ECG-based CPC estimation may provide additional prognostic information for both sleep medicine and autonomic function analysis. Copyright © 2016 IPEM. Published by Elsevier Ltd. All rights reserved.
Baharfar, Mahroo; Yamini, Yadollah; Seidi, Shahram; Arain, Muhammad Balal
2018-05-30
A new design of electromembrane extraction (EME) as a lab on-a-chip device was proposed for the extraction and determination of phenazopyridine as the model analyte. The extraction procedure was accomplished by coupling of EME and the packing of a sorbent. The analyte was extracted under the applied electrical field across a membrane sheet impregnated by nitrophenyl octylether (NPOE) into an acceptor phase. It was followed by the absorption of the analyte on strong cation exchanger as a sorbent. The designed chip contained separate spiral channels for donor and acceptor phases featuring embedded platinum electrodes to enhance extraction efficiency. The selected donor and acceptor phases were 0 mM HCl and 100 mM HCl, respectively. The on-chip electromembrane extraction was carried out under the voltage level of 70 V for 50 min. The analysis was carried out by two modes of a simple Red-Green-Blue (RGB) image analysis tool and a conventional HPLC-UV system. After the absorption of the analyte on the solid phase, its color changed and a digital picture of the sorbent was taken for the RGB analysis. The effective parameters on the performance of the chip device, comprising the EME and solid phase microextraction steps, were distinguished and optimized. The accumulation of the analyte on the solid phase showed excellent sensitivity and a limit of detection (LOD) lower than 1.0 μg L-1 achieved by an image analysis using a smartphone. This device also offered acceptable intra- and inter-assay RSD% (<10%). The calibration curves were linear within the range of 10-1000 μg L-1 and 30-1000 μg L-1 (r2 > 0.9969) for HPLC-UV and RGB analysis, respectively. To investigate the applicability of the method in complicated matrices, urine samples of patients being treated with phenazopyridine were analyzed.
NASA Astrophysics Data System (ADS)
Gutiérrez-Solís, M. C.; Muñoz-Rodríguez, D.; Medina-Peralta, S.; Carrera-Figueiras, C.; Ávila-Ortega, A.
2013-06-01
A sorbent material based on silica particles modified with poly(N-vinylimidazole) (SiO2-PVI) has been evaluated for the treatment of samples by matrix solid-phase dispersion (MSPD). The extraction of four organophosphorus pesticides was done from a spiked tomato and the extracts were analyzed by gas chromatography coupled to mass spectrometry. Six elution solvents were evaluated and acetone was selected due to better recovery of the four pesticides and low background signal in the chromatograms. A factorial design 24 was used for selection of extraction conditions. The factors were contact time, acetone volume, treatment (with or without freeze-drying) and adsorbent (SiO2 or SiO2-PVI). The best recoveries were obtained using 15 minutes of contact, 2 mL of solvent and sorbent without freeze-drying. The recoveries were between 60 and 83% for SiO2-PVI in spiked tomato with 0.2 and 0.8μg/g.
Hu, Yanxue; Yang, Xiumin; Wang, Zhi; Wang, Chun; Zhao, Jin
2005-11-01
A novel method for the determination of carbendazim (MBC) and thiabendazole (TBZ) in tomatoes by solid-phase microextraction (SPME) coupled with high performance liquid chromatography (HPLC) and fluorescence detection was developed. The experimental conditions of SPME, including extraction fiber, extraction time, extraction temperature, desorption time, desorption solvent, desorption mode, pH value, organic solvent and ionic strength, and HPLC conditions were optimized. The SPME for MBC and TBZ was performed on a 65 microm polydimethylsiloxane/divinylbenzene (PDMS/DVB) fibre for 50 min at room temperature with the solution being stirred at 1 100 r/min. The florescence detection was made at 315 nm with excitation wavelength at 280 nm. The method is linear for MBC and TBZ over the range assayed from 0.01 to 1.0 mg/kg tomatoes with the detection limits of 0.003 mg/kg and 0. 001 mg/kg and the correlation coefficients of 0.995 8 and 0.996 7, respectively. The average recoveries for MBC and TBZ were 83.5% and 85.6% with the relative standard deviations (RSDs) of 6.5% and 3.8%, respectively. The method is fast, simple, sensitive, solvent-free and suitable for the determination of MBC and TBZ in tomatoes.
Molecular Analyzer for Complex Refractory Organic-Rich Surfaces (MACROS)
NASA Technical Reports Server (NTRS)
Getty, Stephanie A.; Cook, Jamie E.; Balvin, Manuel; Brinckerhoff, William B.; Li, Xiang; Grubisic, Andrej; Cornish, Timothy; Ferrance, Jerome; Southard, Adrian
2017-01-01
The Molecular Analyzer for Complex Refractory Organic-rich Surfaces, MACROS, is a novel instrument package being developed at NASA Goddard Space Flight Center. MACROS enables the in situ characterization of a sample's composition by coupling two powerful techniques into one compact instrument package: (1) laser desorption/ionization time-of-flight mass spectrometry (LDMS) for broad detection of inorganic mineral composition and non-volatile organics, and (2) liquid-phase extraction methods to gently isolate the soluble organic and inorganic fraction of a planetary powder for enrichment and detailed analysis by liquid chromatographic separation coupled to LDMS. The LDMS is capable of positive and negative ion detection, precision mass selection, and fragment analysis. Two modes are included for LDMS: single laser LDMS as the broad survey mode and two step laser mass spectrometry (L2MS). The liquid-phase extraction will be done in a newly designed extraction module (EM) prototype, providing selectivity in the analysis of a complex sample. For the sample collection, a diamond drill front end will be used to collect rock/icy powder. With all these components and capabilities together, MACROS offers a versatile analytical instrument for a mission targeting an icy moon, carbonaceous asteroid, or comet, to fully characterize the surface composition and advance our understanding of the chemical inventory present on that body.
Ma, Hanna; Zhu, Mengya; Wang, Yalin; Sun, Tonghua; Jia, Jinping
2009-05-01
A gas chromatography (GC) coupled with solid-phase micro-extraction using a special activated carbon fiber (ACF) was developed for the analysis of 6 nitroaromatics and cyclic ketones, nitrobenzene (NB), 1,3-dinitrobenzene (1,3-DNB), 2,4-dinitrotoluene (2,4-DNT), 2,6-dinitrotoluene (2,6-DNT), isophorone, 1,4-naphthaquinone (1,4-NPQ), in sea water samples. The sample was extracted for 30 min under saturation of NaCl at 1,500 r/min and 60 degrees C in head space. The desorption was performance at 280 degrees C for 2 min. The linear ranges were from 0.01 to 400 microg/L. The limits of detection (LODs) were 1.4 - 3.2 ng/L. This method has been successfully applied to the determination of nitroaromatics and cyclic ketones in the sea water samples obtained from East China Sea. The concentrations of nitrobenzene, 1,3-dinitrobenzene and 2,6-dinitrotoluene in the sea water sample were 0.756, 0.944, 0.890 microg/L, respectively. The recoveries were 86.3% - 101.8% with the relative standard deviations (RSDs) of 3.7% -7.8%. The method is suitable for analyzing nitroaromatics and cyclic ketones at low concentration levels in sea water samples.
Shih, Tsung-Ting; Hsieh, Cheng-Chuan; Luo, Yu-Ting; Su, Yi-An; Chen, Ping-Hung; Chuang, Yu-Chen; Sun, Yuh-Chang
2016-04-15
Herein, a hyphenated system combining a high-throughput solid-phase extraction (htSPE) microchip with inductively coupled plasma-mass spectrometry (ICP-MS) for rapid determination of trace heavy metals was developed. Rather than performing multiple analyses in parallel for the enhancement of analytical throughput, we improved the processing speed for individual samples by increasing the operation flow rate during SPE procedures. To this end, an innovative device combining a micromixer and a multi-channeled extraction unit was designed. Furthermore, a programmable valve manifold was used to interface the developed microchip and ICP-MS instrumentation in order to fully automate the system, leading to a dramatic reduction in operation time and human error. Under the optimized operation conditions for the established system, detection limits of 1.64-42.54 ng L(-1) for the analyte ions were achieved. Validation procedures demonstrated that the developed method could be satisfactorily applied to the determination of trace heavy metals in natural water. Each analysis could be readily accomplished within just 186 s using the established system. This represents, to the best of our knowledge, an unprecedented speed for the analysis of trace heavy metal ions. Copyright © 2016 Elsevier B.V. All rights reserved.
Song, Xingliang; Li, Jinhua; Xu, Shoufang; Ying, Rongjian; Ma, Jiping; Liao, Chunyang; Liu, Dongyan; Yu, Junbao; Chen, Lingxin
2012-09-15
A method of solid-phase extraction (SPE) using molecularly imprinted polymers (MIPs) as adsorbent coupled with gas chromatography-mass spectrometry (GC-MS) was developed for the determination of 16 types of polycyclic aromatic hydrocarbons (PAHs) in seawater samples. The MIPs were prepared through non-covalent polymerization by using the 16 PAHs mixture as a template based on sol-gel surface imprinting. Compared with the non-imprinted polymers (NIPs), the MIPs exhibited excellent affinity towards 16 PAHs with binding capacity of 111.0-195.0 μg g(-1), and imprinting factor of 1.50-3.12. The significant binding specificity towards PAHs even in the presence of environmental parameters such as dissolved organic matter and various metal ions, suggested that this new imprinting material was capable of removing 93.2% PAHs in natural seawater. High sensitivity was attained, with the low limits of detection for 16 PAHs in natural seawater ranging from 5.2-12.6 ng L(-1). The application of MIPs with high affinity and excellent stereo-selectivity toward PAHs in SPE might offer a more attractive alternative to conventional sorbents for extraction and abatement of PAH-contaminated seawater. Copyright © 2012 Elsevier B.V. All rights reserved.
He, Maofang; Wang, Chaozhan; Wei, Yinmao
2016-01-15
In this paper, iminodiacetic acid-Cu(II) functionalized Fe3O4@SiO2 magnetic nanoparticles were prepared and used as new adsorbents for magnetic solid phase extraction (MSPE) of six monoamine neurotransmitters (MNTs) from rabbit plasma. The selective enrichment of MNTs at pH 5.0 was motivated by the specific coordination interaction between amino groups of MNTs and the immobilized Cu(II). The employed weak acidic extraction condition avoided the oxidation of MNTs, and thus facilitated operation and ensured higher recoveries. Under optimal conditions, the recoveries of six MNTs from rabbit plasma were in the range of 83.9-109.4%, with RSD of 2.0-10.0%. When coupled the Cu(II) immobilized MSPE with high-performance liquid chromatography-fluorescence detection, the method exhibited relatively lower detection limits than the previously reported methods, and the method was successfully used to determine the endogenous MNTs in rabbit plasma. The proposed method has potential application for the determination of MNTs in biological samples. Also, the utilization of coordination interaction to improve the selectivity might open another way to selectively enrich small alkaloids from complex samples. Copyright © 2015 Elsevier B.V. All rights reserved.
Tomková, Jana; Ondra, Peter; Válka, Ivo
2015-06-01
This paper presents a method for the simultaneous determination of α-amanitin, β-amanitin and muscarine in human urine by solid-phase extraction (SPE) and ultra-high-performance liquid chromatography coupled with ultra-high-resolution TOF mass spectrometry. The method can be used for a diagnostics of mushroom poisonings. Different SPE cartridges were tested for sample preparation, namely hydrophilic modified reversed-phase (Oasis HLB) and polymeric weak cation phase (Strata X-CW). The latter gave better results and therefore it was chosen for the subsequent method optimization and partial validation. In the course of validation, limits of detection, linearity, intraday and interday precisions and recoveries were evaluated. The obtained LOD values of α-amanitin and β-amanitin were 1ng/mL and of muscarine 0.09ng/mL. The intraday and interday precisions of human urine spiked with α-amanitin (10ng/mL), β-amanitin (10ng/mL) and muscarine (1ng/mL) ranged from 6% to 10% and from 7% to 13%, respectively. The developed method was proved to be a relevant tool for the simultaneous determination of the studied mushroom toxins in human urine after mushroom poisoning. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Li, Danping; Ma, Xiaoguo; Wang, Rui; Yu, Yumian
2017-02-01
Bisphenol A (BPA), an endocrine-disrupting chemical, has received much attention from researchers and the general public. In this paper, a novel method of determining BPA at trace levels was developed, using magnetic reduced graphene oxide (rGO-Fe 3 O 4 )-based solid-phase extraction coupled with dispersive liquid-liquid microextraction (DLLME), followed by high-performance liquid chromatographic determination. The rGO-Fe 3 O 4 was prepared and then characterized by Fourier transform infrared spectroscopy, transmission electron microscopy, and vibrating sample magnetometry. The greatest saturation magnetization of rGO-Fe 3 O 4 was up to 43.8 emu g -1 , which allowed rapid isolation of the rGO-Fe 3 O 4 from solutions upon applying an appropriate magnetic field. The effects of solution pH, adsorbent amount, type and volume of eluent and extraction solvent, extraction time, and salt concentration on the extraction efficiency of BPA were examined and optimized. Under the optimum conditions, an enrichment factor of 5217 and an LOD of 0.01 μg L -1 for BPA were obtained. The reusability of rGO-Fe 3 O 4 for at least 12 repeated cycles without any significant decrease in the extraction recovery of BPA was demonstrated. The proposed method was applied to the determination of BPA in different real water samples, with relative recoveries of 84.8-104.9 % and RSDs of 0.8-8.3 % in the spiked concentration range 1-10 μg L -1 .
Luo, Xialin; Li, Gongke; Hu, Yufei
2017-04-01
In this work, a novel NH 2 -MIL-53(Al) incorporated poly(styrene-divinylbenzene-methacrylic acid) (poly(St-DVB-MAA)) monolith was prepared via chemical fabrication. Moreover, it has been efficiently applied to the in-tube solid-phase microextraction (SPME) for online coupling with high-performance liquid chromatography (HPLC) to the direct determination of five estrogens in human urine samples. The NH 2 -MIL-53(Al)-polymer monolith was suitable for in-tube SPME owing to its good permeability, high extraction efficiency, chemical stability, good reproducibility and long lifetime. The extraction conditions including extraction solvent, pH of sample solution, flow rate of extraction and desorption, and desorption volume were investigated. Under the optimum conditions, the enrichment factors were 180-304 and saturated amounts of extraction were 2326-21393 pmol for estriol, 17β-estradiol, estrone, ethinyl estradiol and progesterone, respectively. The adsorption mechanism was also explored which contributed to its strong extraction to target compounds. The proposed method had low limit of detection (2.0-40ng/L) and good linearity (with R 2 between 0.9908 and 0.9978). Four endogenous estrogens were detected in urine samples and the recoveries of all five analytes were ranged from 75.1-120% with relative standard deviations (RSDs) less than 8.7%. The results showed that the proposed online SPME-HPLC method based on NH 2 -MIL-53(Al)-polymer monolithic column was highly sensitive for directly monitoring trace amount of estrogens in human urine sample. Copyright © 2016 Elsevier B.V. All rights reserved.
Separation techniques for the clean-up of radioactive mixed waste for ICP-AES/ICP-MS analysis
DOE Office of Scientific and Technical Information (OSTI.GOV)
Swafford, A.M.; Keller, J.M.
1993-03-17
Two separation techniques were investigated for the clean-up of typical radioactive mixed waste samples requiring elemental analysis by Inductively Coupled Plasma-Atomic Emission Spectroscopy (ICP-AES) or Inductively Coupled Plasma-Mass Spectrometry (ICP-MS). These measurements frequently involve regulatory or compliance criteria which include the determination of elements on the EPA Target Analyte List (TAL). These samples usually consist of both an aqueous phase and a solid phase which is mostly an inorganic sludge. Frequently, samples taken from the waste tanks contain high levels of uranium and thorium which can cause spectral interferences in ICP-AES or ICP-MS analysis. The removal of these interferences ismore » necessary to determine the presence of the EPA TAL elements in the sample. Two clean-up methods were studied on simulated aqueous waste samples containing the EPA TAL elements. The first method studied was a classical procedure based upon liquid-liquid extraction using tri-n- octylphosphine oxide (TOPO) dissolved in cyclohexane. The second method investigated was based on more recently developed techniques using extraction chromatography; specifically the use of a commercially available Eichrom TRU[center dot]Spec[trademark] column. Literature on these two methods indicates the efficient removal of uranium and thorium from properly prepared samples and provides considerable qualitative information on the extraction behavior of many other elements. However, there is a lack of quantitative data on the extraction behavior of elements on the EPA Target Analyte List. Experimental studies on these two methods consisted of determining whether any of the analytes were extracted by these methods and the recoveries obtained. Both methods produced similar results; the EPA target analytes were only slightly or not extracted. Advantages and disadvantages of each method were evaluated and found to be comparable.« less
Yan, Hongyuan; Qiao, Jindong; Pei, Yuning; Long, Tao; Ding, Wen; Xie, Kun
2012-05-01
New molecularly imprinted microspheres synthesized by suspension polymerisation using phenylamine and naphthol as mimic template were successfully applied as selective sorbents for the solid-phase extraction used for the simultaneous determination of four Sudan dyes from preserved beancurd products. The obtained imprinted microspheres showed good recognition and selectivity to the four Sudan dyes in aqueous solution and the affinity could be easily controlled by adjusting the property of the solution. Under the selected experimental condition, the recoveries of the Sudan dyes in preserved beancurds at three spiked levels were ranged between 90.2-104.5% with the relative standard deviation of less than 6.8%. The limit of detection (LOD) and limit of quantification (LOQ) based on a signal-to-noise of 3 and 10 were in the range of 0.005-0.009μgg(-1) and 0.015-0.030μgg(-1), respectively. Comparing with alumina and C18-based extraction, the selectivity and repeatability of molecularly imprinted solid-phase extraction (MISPE) were obviously improved. This method could be potentially applied for the determination of Sudan dyes in complicated food samples. Copyright © 2011 Elsevier Ltd. All rights reserved.
Wang, Hui; Wang, Ruiling; Han, Yehong
2014-02-15
An inorganic-organic co-functional monomer, methacrylic acid-vinyltriethoxysilan (MAA-VTES) was designed for the synthesis of molecularly imprinted microspheres (MIMs). By virtue of the aqueous suspension polymerization and dummy template (pazufloxacin), the obtained MAA-VTES based MIMs exhibited good recognition and selectivity to fluoroquinolones (FQs), and were successfully applied as selective sorbents of a miniaturized home-made solid phase extraction device for the determination of ofloxacin (OFL), lomefloxacin (LOM) and ciprofloxacin (CIP) in milk samples. Under the optimum conditions of the miniaturized molecularly imprinted solid phase extraction (mini-MISPE) coupled with liquid chromatography-ultraviolet detector (LC-UV), good linearities were obtained for three FQs in a range of 0.2-20.0μgmL(-1) and the average recoveries at three spiked levels were ranged from 87.2% to 106.1% with the relative standard deviation (RSD) less than 5.4%. The presented co-functional monomer based mini-MISPE-LC-UV protocol introduced the rigidity and flexibility of inorganic silicon materials, exhibited excellent extraction performance towards targets, and could be potentially applied to the determination of FQs in milk samples. Copyright © 2013 Elsevier B.V. All rights reserved.
Pastor-Belda, Marta; Viñas, Pilar; Campillo, Natalia; Hernández-Córdoba, Manuel
2017-04-15
Magnetic solid phase extraction (MSPE) with cobalt ferrite nanoparticles coated with oleic acid is described for the determination of alkylphenols (APs), 4-tert-butylphenol (TBP), 4-pentylphenol (PP), 4-hexylphenol (HP), 4-tert-octylphenol (TOP), 4-n-octylphenol (OP) and 4-nonylphenol (NP) in baby foods using gas chromatography with mass spectrometry (GC-MS). Prior to MSPE, the sample was treated with trichloroacetic acid, and the APs derivatized with acetic anhydride. Parameters affecting the extraction efficiency: amount of magnetic nanoparticles, extraction time and desorption conditions, were optimized. The enriched phase obtained was evaporated to dryness and the residue reconstituted in 50μL of methanol, 1μL of which was injected into the GC-MS. Samples were quantified applying matrix-matched calibration and using 2-chloro-5-bromoanisole as surrogate standard. The analysis of 0.5g of sample provided detection limits in the 0.4-1.7ngg -1 range. Some samples contained APs at levels of between 3ngg -1 for HP and 122ngg -1 for TOP. Copyright © 2016 Elsevier Ltd. All rights reserved.
Gao, Zhanqi; Deng, Yuehua; Yuan, Wenting; He, Huan; Yang, Shaogui; Sun, Cheng
2014-10-31
A novel method was developed for the determination of organophosphorus flame retardants (PFRs) in fish. The method consists of a combination of pressurized liquid extraction (PLE) using aqueous solutions and solid-phase microextraction (SPME), followed by gas chromatography-flame photometric detector (GC-FPD). The experimental parameters that influenced extraction efficiency were systematically evaluated. The optimal responses were observed by extracting 1g of fish meat with the solution of water:acetonitrile (90:10, v/v) at 150°C for 5min and acid-washed silica gel used as lipid sorbent. The obtained extract was then analyzed by SPME coupled with GC-FPD without any additional clean-up steps. Under the optimal conditions, the proposed procedure showed a wide linear range (0.90-5000ngg(-1)) obtained by analyzing the spiked fish samples with increasing concentrations of PFRs and correlation coefficient (R) ranged from 0.9900 to 0.9992. The detection limits (S/N=3) were in the range of 0.010-0.208ngg(-1) with standard deviations (RSDs) ranging from 2.0% to 9.0%. The intra-day and inter-day variations were less than 9.0% and 7.8%, respectively. The proposed method was successfully applied to the determination of PFRs in real fish samples with recoveries varying from 79.8% to 107.3%. The results demonstrate that the proposed method is highly effective for analyzing PFRs in fish samples. Copyright © 2014 Elsevier B.V. All rights reserved.
Zhang, Yuchi; Guo, Liping; Liu, Chunming; Fu, Zi' ao; Cong, Lei; Qi, Yanjuan; Li, Dongping; Li, Sainan; Wang, Jing
2013-09-15
Pressurized liquid extraction (PLE) coupled with high-speed countercurrent chromatography (HSCCC) via an automated procedure was firstly developed to extract and isolate ginsenosides from Panax quinquefolium. The experiments were designed under the guidance of mathematical model. The partition coefficient (K) values of the target compounds and resolutions of peak profiles were employed as the research indicators, and exponential function and binomial formulas were used to optimizing the solvent systems and flow rates of the mobile phases in a three-stage separation. In the first stage, ethyl acetate, n-butanol, and water were simultaneously pumped into the solvent separator at the flow rates 11.0, 10.0, and 23.0mL/min, respectively. The upper phase of the solvent system in the solvent separator was used as both the PLE solvent and the HSCCC stationary phase, followed by elution with the lower phase of the corresponding solvent system to separate the common ginsenosides. In the second and third stages, rare ginsenosides were first separated by elution with ethyl acetate, n-butanol, methanol, and water (flow rates: 20.0, 3.0, 5.0, and 11.0mL/min, respectively), then with n-heptane, n-butanol, methanol, and water (flow rates: 17.5, 6.0, 5.0, and 22.5mL/min, respectively). Nine target compounds, with purities exceeding 95.0%, and three non-target compounds, with purities above 84.48%, were successfully separated at the semipreparative scale in 450min. The separation results prove that the PLE/HSCCC parameters calculated via mathematical model and formulas were accurately and scientifically. This research has opened up great prospects for industrial automation application. Copyright © 2013 Elsevier B.V. All rights reserved.
Huang, Fangzhi; Berton, Paula; Lu, Chengfei; Siraj, Noureen; Wang, Chun; Magut, Paul K S; Warner, Isiah M
2014-09-01
A rapid liquid phase extraction employing a novel hydrophobic surfactant-based room temperature ionic liquid (RTIL), tetrabutylphosphonium dioctyl sulfosuccinate ([4C4 P][AOT]), coupled with capillary electrophoretic-UV (CE-UV) detection is developed for removal and determination of phenolic compounds. The long-carbon-chain RTIL used is sparingly soluble in most solvents and can be used to replace volatile organic solvents. This fact, in combination with functional-surfactant-anions, is proposed to reduce the interfacial energy of the two immiscible liquid phases, resulting in highly efficient extraction of analytes. Several parameters that influence the extraction efficiencies, such as extraction time, RTIL type, pH value, and ionic strength of aqueous solutions, were investigated. It was found that, under acidic conditions, most of the investigated phenols were extracted from aqueous solution into the RTIL phase within 12 min. Good linearity was observed over the concentration range of 0.1-80.0 μg/mL for all phenols investigated. The precision of this method, expressed as RSD, was determined to be within 3.4-5.3% range. The LODs (S/N = 3) of the method were in the range of 0.047-0.257 μg/mL. The proposed methodology was successfully applied to determination of phenols in real water samples. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Criado-García, Laura; Arce, Lourdes
2016-09-01
A new sample extraction procedure based on micro-solid-phase extraction (μSPE) using a mixture of sorbents of different polarities (polymeric reversed-phase sorbent HLB, silica-based sorbent C18, and multiwalled carbon nanotubes) was applied to extract benzene, toluene, butyraldehyde, benzaldehyde, and tolualdehyde present in saliva to avoid interference from moisture and matrix components and enhance sensitivity and selectivity of the ion mobility spectrometry (IMS) methodology proposed. The extraction of target analytes from saliva samples by using μSPE were followed by the desorption step carried out in the headspace vials placed in the autosampler of the IMS device. Then, 200 μL of headspace was injected into the GC column coupled to the IMS for its analysis. The method was fully validated in terms of sensitivity, precision, and recovery. The LODs and LOQs obtained, when analytes were dissolved in saliva samples to consider the matrix effect, were within the range of 0.38-0.49 and 1.26-1.66 μg mL(-1), respectively. The relative standard deviations were <3.5 % for retention time and drift time values, which indicate that the method proposed can be applied to determine toxic compounds in saliva samples. Graphical abstract Summary of steps followed in the experimental set up of this work.
Kataoka, H; Narimatsu, S; Lord, H L; Pawliszyn, J
1999-10-01
The technique of automated in-tube solid-phase microextraction (SPME) coupled with liquid chromatography/electrospray ionization mass spectrometry (LC/ESI-MS) was evaluated for the determination of beta-blockers in urine and serum samples. In-tube SPME is an extraction technique for organic compounds in aqueous samples, in which analytes are extracted from the sample directly into an open tubular capillary by repeated draw/eject cycles of sample solution. LC/MS analyses of beta-blockers were initially performed by liquid injection onto a LC column. Nine beta-blockers tested in this study gave very simple ESI mass spectra, and strong signals corresponding to [M + H]+ were observed for all beta-blockers. The beta-blockers were separated with a Hypersil BDS C18 column using acetonitrile/methanol/water/acetic acid (15:15:70:1) as a mobile phase. To optimize the extraction of beta-blockers, several in-tube SPME parameters were examined. The optimum extraction conditions were 15 draw/eject cycles of 30 microL of sample in 100 mM Tris-HCl (pH 8.5) at a flow rate of 100 microL/min using an Omegawax 250 capillary (Supelco, Bellefonte, PA). The beta-blockers extracted by the capillary were easily desorbed by mobile-phase flow, and carryover of beta-blockers was not observed. Using in-tube SPME/LC/ESI-MS with selected ion monitoring, the calibration curves of beta-blockers were linear in the range from 2 to 100 ng/mL with correlation coefficients above 0.9982 (n = 18) and detection limits (S/N = 3) of 0.1-1.2 ng/mL. This method was successfully applied to the analysis of biological samples without interference peaks. The recoveries of beta-blockers spiked into human urine and serum samples were above 84 and 71%, respectively. A serum sample from a patient administrated propranolol was analyzed using this method and both propranolol and its metabolites were detected.
Casado, Natalia; Morante-Zarcero, Sonia; Pérez-Quintanilla, Damián; Sierra, Isabel
2016-08-12
A quick, sensitive and selective analytical reversed-phase multi-residue method using ultra-high performance liquid chromatography coupled to an ion-trap mass spectrometry detector (UHPLC-IT-MS/MS) operating in both positive and negative ion mode was developed for the simultaneous determination of 23 veterinary drug residues (β-blockers, β-agonists and Non-Steroidal Anti-inflammatory Drugs (NSAIDs)) in meat samples. The sample treatment involved a liquid-solid extraction followed by a solid-phase extraction (SPE) procedure. SBA-15 type mesoporous silica was synthetized and modified with octadecylsilane, and the resulting hybrid material (denoted as SBA-15-C18) was applied and evaluated as SPE sorbent in the purification of samples. The materials were comprehensively characterized, and they showed a high surface area, high pore volume and a homogeneous distribution of the pores. Chromatographic conditions and extraction procedure were optimized, and the method was validated according to the Commission Decision 2002/657/EC. The method detection limits (MDLs) and the method quantification limits (MQLs) were determined for all the analytes in meat samples and found to range between 0.01-18.75μg/kg and 0.02-62.50μg/kg, respectively. Recoveries for 15 of the target analytes ranged from 71 to 98%. In addition, for comparative purpose SBA-15-C18 was evaluated towards commercial C18 amorphous silica. Results revealed that SBA-15-C18 was clearly more successful in the multi-residue extraction of the 23 mentioned analytes with higher recovery values. The method was successfully tested to analyze prepacked preparations of mince bovine meat. Traces of propranolol, ketoprofen and diclofenac were detected in some samples. Copyright © 2016 Elsevier B.V. All rights reserved.
Liao, Wenta; Ghabour, Miriam; Draper, William M; Chandrasena, Esala
2016-09-01
Purge and trap sample introduction (PTI) has been the premier sampling and preconcentration technique for gas chromatographic determination of volatile organic compounds (VOCs) in drinking water for almost 50 years. PTI affords sub parts-per-billion (ppb) detection limits for purgeable VOCs including fixed gases and higher boiling hydrocarbons and halocarbons. In this study the coupling of solid phase extraction (SPE) to PTI was investigated as a means to substantially increase enrichment and lower detection limits for the emerging contaminant, 1,2,3-trichloropropane (TCP). Water samples (500 mL) were dechlorinated, preserved with a biocide, and spiked with the isotope labeled internal standard, d5-TCP. The entire 500 mL sample was extracted with activated carbon or carbon molecular sieve SPE cartridges, and then eluted with dichloromethane -- excess solvent was removed in a nitrogen evaporator and diethylene glycol "keeper" remaining was dispersed in 5 mL of water for PTI GC-MS analysis. The experimental Method Detection Limit (MDL) for TCP was 0.11 ng/L (ppt) and accuracy was 95-103% in sub-ppt determinations. Groundwater samples including impaired California sources and treated water (n = 21) were analyzed with results ranging from below the method reporting limit (0.30 ng/L) to > 250 ng/L. Coupling of SPE with PTI may provide similar reductions in detection limits for other VOCs with appropriate physical-chemical properties. Copyright © 2016 Elsevier Ltd. All rights reserved.
USDA-ARS?s Scientific Manuscript database
The objectives of this study were to characterize volatile compounds and to determine the characteristic aromas associated with impact compounds in 4 fish sauces using solid-phase micro-extraction, gas chromatography-mass spectrometry, Osme, and gas chromatography olfactometry (SPME-Osme-GCO) couple...
Quinn, Casey W; Cate, David M; Miller-Lionberg, Daniel D; Reilly, Thomas; Volckens, John; Henry, Charles S
2018-03-20
Metal contamination of natural and drinking water systems poses hazards to public and environmental health. Quantifying metal concentrations in water typically requires sample collection in the field followed by expensive laboratory analysis that can take days to weeks to obtain results. The objective of this work was to develop a low-cost, field-deployable method to quantify trace levels of copper in drinking water by coupling solid-phase extraction/preconcentration with a microfluidic paper-based analytical device. This method has the advantages of being hand-powered (instrument-free) and using a simple "read by eye" quantification motif (based on color distance). Tap water samples collected across Fort Collins, CO, were tested with this method and validated against ICP-MS. We demonstrate the ability to quantify the copper content of tap water within 30% of a reference technique at levels ranging from 20 to 500 000 ppb. The application of this technology, which should be sufficient as a rapid screening tool, can lead to faster, more cost-effective detection of soluble metals in water systems.
NASA Technical Reports Server (NTRS)
Kleinman, Leonid S.; Red, X. B., Jr.
1995-01-01
An algorithm has been developed for time-dependent forced convective diffusion-reaction having convection by a recirculating flow field within the drop that is hydrodynamically coupled at the interface with a convective external flow field that at infinity becomes a uniform free-streaming flow. The concentration field inside the droplet is likewise coupled with that outside by boundary conditions at the interface. A chemical reaction can take place either inside or outside the droplet, or reactions can take place in both phases. The algorithm has been implemented, and for comparison results are shown here for the case of no reaction in either phase and for the case of an external first order reaction, both for unsteady behavior. For pure interphase mass transfer, concentration isocontours, local and average Sherwood numbers, and average droplet concentrations have been obtained as a function of the physical properties and external flow field. For mass transfer enhanced by an external reaction, in addition to the above forms of results, we present the enhancement factor, with the results now also depending upon the (dimensionless) rate of reaction.
ACCELERATED SOLVENT EXTRACTION COMBINED WITH ...
A research project was initiated to address a recurring problem of elevated detection limits above required risk-based concentrations for the determination of semivolatile organic compounds in high moisture content solid samples. This project was initiated, in cooperation with the EPA Region 1 Laboratory, under the Regional Methods Program administered through the ORD Office of Science Policy. The aim of the project was to develop an approach for the rapid removal of water in high moisture content solids (e.g., wetland sediments) in preparation for analysis via Method 8270. Alternative methods for water removal have been investigated to enhance compound solid concentrations and improve extraction efficiency, with the use of pressure filtration providing a high-throughput alternative for removal of the majority of free water in sediments and sludges. In order to eliminate problems with phase separation during extraction of solids using Accelerated Solvent Extraction, a variation of a water-isopropanol extraction method developed at the USGS National Water Quality Laboratory in Denver, CO is being employed. The concentrations of target compounds in water-isopropanol extraction fluids are subsequently analyzed using an automated Solid Phase Extraction (SPE)-GC/MS method developed in our laboratory. The coupled approaches for dewatering, extraction, and target compound identification-quantitation provide a useful alternative to enhance sample throughput for Me
DOE Office of Scientific and Technical Information (OSTI.GOV)
Walworth, Matthew J; ElNaggar, Mariam S; Stankovich, Joseph J
Direct liquid extraction based surface sampling, a technique previously demonstrated with continuous flow and autonomous pipette liquid microjunction surface sampling probes, has recently been implemented as the Liquid Extraction Surface Analysis (LESA) mode on the commercially available Advion NanoMate chip-based infusion nanoelectrospray ionization system. In the present paper, the LESA mode was applied to the analysis of 96-well format custom solid phase extraction (SPE) cards, with each well consisting of either a 1 or 2 mm diameter monolithic hydrophobic stationary phase. These substrate wells were conditioned, loaded with either single or multi-component aqueous mixtures, and read out using the LESAmore » mode of a TriVersa NanoMate or a Nanomate 100 coupled to an ABI/Sciex 4000QTRAPTM hybrid triple quadrupole/linear ion trap mass spectrometer and a Thermo LTQ XL linear ion trap mass spectrometer. Extraction conditions, including extraction/nanoESI solvent composition, volume, and dwell times, were optimized in the analysis of targeted compounds. Limit of detection and quantitation as well as analysis reproducibility figures of merit were measured. Calibration data was obtained for propranolol using a deuterated internal standard which demonstrated linearity and reproducibility. A 10x increase in signal and cleanup of micromolar Angiotensin II from a concentrated salt solution was demonstrated. Additionally, a multicomponent herbicide mixture at ppb concentration levels was analyzed using MS3 spectra for compound identification in the presence of isobaric interferences.« less
Chen, Bo; Huang, Yuming
2014-06-25
Dispersive liquid-phase microextraction with solidification of floating organic drop (SFO-DLPME) is one of the most interesting sample preparation techniques developed in recent years. In this paper, a new, rapid, and efficient SFO-DLPME coupled with high-performance liquid chromatography (HPLC) was established for the extraction and sensitive detection of banned Sudan dyes, namely, Sudan I, Sudan II, Sudan III, and Sudan IV, in foodstuff and water samples. Various factors, such as the type and volume of extractants and dispersants, pH and volume of sample solution, extraction time and temperature, ion strength, and humic acid concentration, were investigated and optimized to achieve optimal extraction of Sudan dyes in one single step. After optimization of extraction conditions using 1-dodecanol as an extractant and ethanol as a dispersant, the developed procedure was applied for extraction of the target Sudan dyes from 2 g of food samples and 10 mL of the spiked water samples. Under the optimized conditions, all Sudan dyes could be easily extracted by the proposed SFO-DLPME method. Limits of detection of the four Sudan dyes obtained were 0.10-0.20 ng g(-1) and 0.03 μg L(-1) when 2 g of foodstuff samples and 10 mL of water samples were adopted, respectively. The inter- and intraday reproducibilities were below 4.8% for analysis of Sudan dyes in foodstuffs. The method was satisfactorily used for the detection of Sudan dyes, and the recoveries of the target for the spiked foodstuff and water samples ranged from 92.6 to 106.6% and from 91.1 to 108.6%, respectively. These results indicated that the proposed method is simple, rapid, sensitive, and suitable for the pre-concentration and detection of the target dyes in foodstuff samples.
Yuan, Su-Fen; Liu, Ze-Hua; Lian, Hai-Xian; Yang, Chuangtao; Lin, Qing; Yin, Hua; Dang, Zhi
2016-10-01
A simple online headspace solid-phase microextraction (HS-SPME) coupled with the gas chromatography-mass spectrometry (GC-MS) method was developed for simultaneous determination of trace amounts of nine estrogenic odorant alkylphenols and chlorophenols and their derivatives in water samples. The extraction conditions of HS-SPME were optimized including fiber selection, extraction temperature, extraction time, and salt concentration. Results showed that divinylbenzene/Carboxen/polydimethylsiloxane (DVB/CAR/PDMS) fiber was the most appropriate one among the three selected commercial fibers, and the optimal extraction temperature, time, and salt concentration were 70 °C, 30 min, and 0.25 g/mL, respectively. The developed method was validated and showed good linearity (R (2) > 0.989), low limit of detection (LOD, 0.002-0.5 μg/L), and excellent recoveries (76-126 %) with low relative standard deviation (RSD, 0.7-12.9 %). The developed method was finally applied to two surface water samples and some of these target compounds were detected. All these detected compounds were below their odor thresholds, except for 2,4,6-TCAS and 2,4,6-TBAS wherein their concentrations were near their odor thresholds. However, in the two surface water samples, these detected compounds contributed to a certain amount of estrogenicity, which seemed to suggest that more attention should be paid to the issue of estrogenicity rather than to the odor problem.
SAW parameters on Y-cut langasite structured materials.
Puccio, Derek; Malocha, Donald C; Saldanha, Nancy; da Cunha, Mauricio Pereira
2007-09-01
This paper presents results and investigations of several new, man-made piezoelectric single crystal, Czochralski-grown substrate materials for surface acoustic waves (SAW) applications. These materials, langanite (LGN), langatate (LGT), Sr3TaGa3Si2O14 (STGS), Sr3NbGa3Si2O14 (SNGS), Ca3TaGa3Si2O14 (CTGS), and Ca3NbGa3Si2O14 (CNGS), have the same structure as langasite (LGS) and are of the same crystal class as quartz. These compounds are denser than quartz, resulting in lower phase velocities. They also have higher coupling. Unlike quartz and lithium niobate, there is no degradation of material properties below the material melting points resulting in the possibility of extreme high-temperature operation (> 1000 degrees C). This paper gives a summary of extracted SAW material parameters for various propagation angles on Y-cut substrates of the six materials. Parameters included are electromechanical coupling, phase velocity, transducer capacitance, metal strip reflectivity, and temperature coefficient of frequency. Using previously published fundamental material constants, extracted parameters are compared with predictions for LGT and LGN. In addition, power flow angle and fractional frequency curvature data are reported for propagation angles on CTGS and CNGS Y-cut substrates that exhibit temperature compensation near room temperature. Detailed descriptions of the SAW parameter extraction techniques are given. A discussion of the results is provided, including a comparison of extracted parameters and an overview of possible SAW applications.
Ma, Chunhua; Ji, Jiaojiao; Tan, Connieal; Chen, Dongmei; Luo, Feng; Wang, Yiru; Chen, Xi
2014-03-01
Oxidation has important effects on the quality of edible oils. In particular, the generation of aldehydes produced by the oxidation of oils is one of the deteriorative factors to their quality. The aim of this study was to develop a method to determine the aldehydes as lipid oxidation markers in edible oils. Seven aldehydes generated from lipid oxidation were studied using headspace solid-phase microextraction coupled to gas chromatography with a flame ionization detector. The extraction efficiency of five commercial fibers was investigated and the influence of extraction temperature, extraction time, desorption temperature, and desorption time were optimized. The best result was obtained with 85 μm carboxen/polydimethylsiloxane, extraction at 50 °C for 15 min and desorption in the gas chromatography injector at 250 °C for 2 min. Under the optimized conditions, the content of hexanal was the highest of the seven aldehydes in all edible oils. The limits of detection for hexanal in the three oils were found to range from 4.6 to 10.2 ng L(-1). The reproducibility of the method was evaluated and the relative standard deviations were less than 8.9%. This developed approach was successfully applied to analyze hexanal in peanut oil, soy oil, and olive oil samples, and these results were compared with those obtained using the thiobarbituric acid-reactive substances (TBARs) method. © 2013 The Authors. Published by Elsevier B.V. All rights reserved.
Njobeh, Patrick B.; Gbashi, Sefater; Adegoke, Gabriel O.; Dubery, Ian A.
2018-01-01
Volatile organic compounds (VOCs) derived from plants have been used in the fragrance industry since time immemorial. Herein we report on the rapid screening of VOCs from seeds of ripe Aframomum danielli (family, Zingiberaceae) using a polydimethylsiloxane fibre headspace solid phase microextraction coupled to a gas chromatography mass spectrometry (SPME-GC/MS) instrument. Portions of 0.25, 0.35, and 0.50 g of ground sample were weighed and extraction of volatile organic compounds (VOCs) was achieved using a 100 μm polydimethylsiloxane solid phase microextraction (PDMS SPME) fibre, with the equilibrium time of 40 minutes and extraction temperature of 50°C; the following compounds with their respective relative abundances were obtained as the top ten most abundant and annotated ones using NIST, Wiley, and Fragrances Libraries: eucalyptol (58%); β-pinene (22%); α-pinene (7.5%); α-terpineol (4%), α-terpinyl acetate (2%); α-bergamotene (1%); pinocarveol (0.39%); α-copaene (0.35%); caryophyllene (0.34); and β-bisabolene (0.31%). These compounds have been reported elsewhere in the literature and listed in the Fragrances Library, incorporated into the Saturn QP2020 GCMS Solution® software used for their analysis. PMID:29849643
NASA Astrophysics Data System (ADS)
Andrle, C. M.; Jakubowski, N.; Broekaert, J. A. C.
1997-02-01
Speciation of Cr(III) and Cr(VI) based on the formation of different complexes with ammonium-pyrrolidinedithioate (APDC) in a continuous flow technique and their preconcentration using solid phase extraction (SPE) have been elaborated and applied to the analysis of waste waters from the galvanic industry. The Cr complexes were separated and determined using reversed phase-high performance liquid chromatography (RP-HPLC) coupled to different detection methods, namely UV-detection, graphite furnace-atomic absorption spectrometry (GF-AAS) and inductively coupled plasma mass spectrometry with hydraulic high pressure nebulization (HHPN/ICP-MS). After optimization the detection limits for Cr(III) and Cr(VI) of all methods are at the μg 1 -1 level and the precision in terms of RSD is 5% ( cCr = 100 μg 1 -1, N = 10). The procedure was applied to the determination of Cr(III) and Cr(VI) at the μg 1 -1 level in galvanic waste waters, and its accuracy was approved by comparing the results with those of independent methods.
NASA Astrophysics Data System (ADS)
Donner, Tobias
2015-03-01
A Bose-Einstein condensate whose motional degrees of freedom are coupled to a high-finesse optical cavity via a transverse pump beam constitutes a dissipative quantum many-body system with long range interactions. These interactions can induce a structural phase transition from a flat to a density-modulated state. The transverse pump field simultaneously represents a probe of the atomic density via cavity- enhanced Bragg scattering. By spectrally analyzing the light field leaking out of the cavity, we measure non-destructively the dynamic structure factor of the fluctuating atomic density while the system undergoes the phase transition. An observed asymmetry in the dynamic structure factor is attributed to the coupling to dissipative baths. Critical exponents for both sides of the phase transition can be extracted from the data. We further discuss our progress in adding strong short-range interactions to this system, in order to explore Bose-Hubbard physics with cavity-mediated long-range interactions and self-organization in lower dimensions.
Zhao, Jiao; Zhu, Yan; Jiao, Yang; Ning, Jinyan; Yang, Yaling
2016-10-01
A novel two-step extraction technique combining ionic-liquid-based dispersive liquid-liquid microextraction with magnetic solid-phase extraction was developed for the preconcentration and separation of aflatoxins in animal feedstuffs before high-performance liquid chromatography coupled with fluorescence detection. In this work, ionic liquid 1-octyl-3-methylimidazolium hexafluorophosphate was used as the extractant in dispersive liquid-liquid microextraction, and hydrophobic pelargonic acid modified Fe 3 O 4 magnetic nanoparticles as an efficient adsorbent were applied to retrieve the aflatoxins-containing ionic liquid. Notably, the target of magnetic nanoparticles was the ionic liquid rather than the aflatoxins. Because of the rapid mass transfer associated with the dispersive liquid-liquid microextraction and magnetic solid phase steps, fast extraction could be achieved. The main parameters affecting the extraction recoveries of aflatoxins were investigated and optimized. Under the optimum conditions, vortexing at 2500 rpm for 1 min in the dispersive liquid-liquid microextraction and magnetic solid-phase extraction and then desorption by sonication for 2 min with acetonitrile as eluent. The recoveries were 90.3-103.7% with relative standard deviations of 3.2-6.4%. Good linearity was observed with correlation coefficients ranged from 0.9986 to 0.9995. The detection limits were 0.632, 0.087, 0.422 and 0.146 ng/mL for aflatoxins B 1 , B2, G1, and G2, respectively. The results were also compared with the pretreatment method carried out by conventional immunoaffinity columns. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Wang, Na; Liao, Yuan; Wang, Jiamin; Tang, Sheng; Shao, Shijun
2015-12-01
A novel bis(indolyl)methane-modified silica reinforced with multiwalled carbon nanotubes sorbent for solid-phase extraction was designed and synthesized by chemical immobilization of nitro-substituted 3,3'-bis(indolyl)methane on silica modified with multiwalled carbon nanotubes. Coupled with high-performance liquid chromatography analysis, the extraction properties of the sorbent were evaluated for flavonoids and aromatic organic acid compounds. Under optimum conditions, the sorbent can simultaneously extract five flavonoids and two aromatic organic acid preservatives in aqueous solutions in a single-step solid-phase extraction procedure. Wide linear ranges were obtained with correlation coefficients (R(2) ) ranging from 0.9843 to 0.9976, and the limits of detection were in the range of 0.5-5 μg/L for the compounds tested. Compared with the silica modified with multiwalled carbon nanotubes sorbent and the nitro-substituted 3,3'-bis(indolyl)methane-modified silica sorbent, the developed sorbent exhibited higher extraction efficiency toward the selected analytes. The synergistic effect of nitro-substituted 3,3'-bis(indolyl)methane and multiwalled carbon nanotubes not only improved the surface-to-volume ratio but also enhanced multiple intermolecular interactions, such as hydrogen bonds, π-π, and hydrophobic interactions, between the new sorbent and the selected analytes. The as-established solid-phase extraction with high-performance liquid chromatography and diode array detection method was successfully applied to the simultaneous determination of flavonoids and aromatic organic acid preservatives in grape juices with recoveries ranging from 83.9 to 112% for all the selected analytes. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Li, Peng; Li, Li-Min; Xia, Jing; Cao, Shuai; Hu, Xin; Lian, Hong-Zhen; Ji, Shen
2015-12-01
An analytical method that combined high-performance liquid chromatography with inductively coupled plasma mass spectrometry has been developed for the determination of hexavalent chromium in traditional Chinese medicines. Hexavalent chromium was extracted using the alkaline solution. The parameters such as the concentration of alkaline and the extraction temperature have been optimized to minimize the interconversion between trivalent chromium and hexavalent chromium. The extracted hexavalent chromium was separated on a weak anion exchange column in isocratic mode, followed by inductively coupled plasma mass spectrometry determination. To obtain a better chromatographic resolution and sensitivity, 75 mM NH4 NO3 at pH 7 was selected as the mobile phase. The linearity of the proposed method was investigated in the range of 0.2-5.0 μg L(-1) (r(2) = 0.9999) for hexavalent chromium. The limits of detection and quantitation are 0.1 and 0.3 μg L(-1) , respectively. The developed method was successfully applied to the determination of hexavalent chromium in Chloriti lapis and Lumbricus with satisfactory recoveries of 95.8-112.8%. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Rajabi, Maryam; Sabzalian, Sedigheh; Barfi, Behruz; Arghavani-Beydokhti, Somayeh; Asghari, Alireza
2015-12-18
A novel, simple, fast, and miniaturized method, termed in-line micro-matrix solid-phase dispersion (in-line MMSPD), coupled with high performance liquid chromatography (HPLC) was developed for the simultaneous extraction and determination of Sudan dyes (i.e. Sudan I-IV, Sudan orange G, Sudan black B, and Sudan red G) with the aid of an experimental design strategy. In this method, a matrix solid-phase dispersion (MSPD) column including a suitable mixture of polar sorbents was inserted in the mobile phase pathway, and while the interfering compounds were retained, the analytes were eluted and entered into the analytical column. In this way, the extraction, elution, and separation of the analytes were performed sequentially. Under the optimal experimental conditions (including the amount of sample, 0.0426g; amount of dispersant phase, 0.0216g of florisil, 0.0227g of silica, 0.0141g of alumina; and blending time, 112s), the limits of detection (LODs), limits of quantification, linear dynamic ranges, and recoveries were obtained to be 0.3-15.3μgkg(-1), 1-50μgkg(-1), 50-28,000μgkg(-1), and 94.5-99.1%, respectively. The results obtained showed that determination of the selected Sudan dyes in food samples using an enough sensitive and a simple analytically validated method like in-line MMSPD may offer a suitable screening method, which could be useful for food analysis and adulteration. Copyright © 2015 Elsevier B.V. All rights reserved.
Superfluid phase stiffness in electron doped superconducting Gd-123
NASA Astrophysics Data System (ADS)
Das, P.; Ghosh, Ajay Kumar
2018-05-01
Current-voltage characteristics of Ce substituted Gd-123 superconductor exhibits nonlinearity below a certain temperature below the critical temperature. An exponent is extracted using the nonlinearity of current-voltage relation. Superfluid phase stiffness has been studied as a function of temperature following the Ambegaokar-Halperin-Nelson-Siggia (AHNS) theory. Phase stiffness of the superfluid below the superconducting transition is found to be sensitive to the change in the carrier concentration in superconducting system. There may be a crucial electron density which affects superfluid stiffness strongly. Electron doping is found to be effective even if the coupling of the superconducting planes is changed.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kertesz, Vilmos; Van Berkel, Gary J
2010-01-01
In this work, a commercially available autosampler was adapted to perform direct liquid microjunction (LMJ) surface sampling followed by a high-pressure liquid chromatography (HPLC) separation of the extract components and detection with electrospray ionization mass spectrometry (ESI-MS). To illustrate the utility of coupling a separation with this direct liquid extraction based surface sampling approach, four different organs (brain, lung, kidney, and liver) from whole-body thin tissue sections of propranolol dosed and control mice were examined. The parent drug was observed in the chromatograms of the surface sampling extracts from all the organs of the dosed mouse examined. In addition, twomore » isomeric phase II metabolites of propranolol (an aliphatic and an aromatic hydroxypropranolol glucuronide) were observed in the chromatograms of the extracts from lung, kidney, and liver. Confirming the presence of one or the other or both of these glucuronides in the extract from the various organs was not possible without the separation. These drug and metabolite data obtained using the LMJ surface sampling/HPLC-MS method and the results achieved by analyzing similar samples by conventional extraction of the tissues and subsequent HPLC-MS analysis were consistent.« less
Ternon, Eva; Tolosa, Imma
2015-07-24
Solid-phase extraction of both aliphatic (AHs) and aromatic polycyclic hydrocarbons (PAHs) from seawater samples was evaluated using a GFF filter stacked upon an octadecyl bonded silica (C18) disk. Stable-isotope measurements were developed on hydrocarbons extracted from both GFF and C18-disks in order to characterize the source of hydrocarbons. A clear partition of hydrocarbon compounds between the dissolved and the particulate phase was highlighted. PAHs showed a higher affinity with the dissolved phase (recoveries efficiency of 48-71%) whereas AHs presented strong affinity with the particulate phase (up to 76% of extraction efficiency). Medium volumes of seawater samples were tested and no breakthrough was observed for a 5L sample. Isotopic fractionation was investigated within all analytical steps but none was evidenced. This method has been applied to harbor seawater samples and very low AH and PAH concentrations were achieved. Due to the low concentration levels of hydrocarbons in the samples, the source of hydrocarbons was determined by molecular indices rather than isotopic measurements and a pyrolytic origin was evidenced. The aliphatic profile also revealed the presence of long-chain linear alkylbenzenes (LABs). The methodology presented here would better fit to polluted coastal environments affected by recent oil spills. Copyright © 2015 Elsevier B.V. All rights reserved.
Xie, Jin; Xie, Jie; Deng, Jian; Fang, Xiangfang; Zhao, Haiqing; Qian, Duo; Wang, Hongjuan
2016-06-01
A novel core-shell magnetic nano-adsorbent with surface molecularly imprinted polymer coating was fabricated and then applied to dispersive micro-solid-phase extraction followed by determination of rhodamine 6G using high-performance liquid chromatography. The molecularly imprinted polymer coating was prepared by copolymerization of dopamine and m-aminophenylboronic acid (functional monomers), in the presence of rhodamine 6G (template). The selection of the suitable functional monomers was based on the interaction between different monomers and the template using the density functional theory. The ratios of the monomers to template were further optimized by an OA9 (3(4) ) orthogonal array design. The binding performances of the adsorbent were evaluated by static, kinetic, and selective adsorption experiments. The results reveal that the adsorbent possesses remarkable affinity and binding specificity for rhodamine 6G because of the enhanced Lewis acid-base interaction between the B(Ш) embedded in the imprinted cavities and the template. The nano-adsorbent was successfully applied to dispersive micro-solid-phase extraction coupled to high-performance liquid chromatography for the trace determination of rhodamine 6G in samples with a detection limit of 2.7 nmol/L. Spiked recoveries ranged from 93.0-99.1, 89.5-92.7, and 86.9-105% in river water, matrimony vine and paprika samples, respectively, with relative standard deviations of less than 4.3%. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
NASA Astrophysics Data System (ADS)
Guo, Yugao; Zhao, He; Han, Yelin; Liu, Xia; Guan, Shan; Zhang, Qingyin; Bian, Xihui
2017-02-01
A simultaneous spectrophotometric determination method for trace heavy metal ions based on solid-phase extraction coupled with partial least squares approaches was developed. In the proposed method, trace metal ions in aqueous samples were adsorbed by cation exchange fibers and desorbed by acidic solution from the fibers. After the ion preconcentration process, the enriched solution was detected by ultraviolet and visible spectrophotometer (UV-Vis). Then, the concentration of heavy metal ions were quantified by analyzing ultraviolet and visible spectrum with the help of partial least squares (PLS) approaches. Under the optimal conditions of operation time, flow rate and detection parameters, the overlapped absorption peaks of mixed ions were obtained. The experimental data showed that the concentration, which can be calculated through chemometrics method, of each metal ion increased significantly. The heavy metal ions can be enriched more than 80-fold. The limits of detection (LOD) for the target analytes of copper ions (Cu2 +), cobalt ions (Co2 +) and nickel ions (Ni2 +) mixture was 0.10 μg L- 1, 0.15 μg L- 1 and 0.13 μg L- 1, respectively. The relative standard deviations (RSD) were less than 5%. The performance of the solid-phase extraction can enrich the ions efficiently and the combined method of spectrophotometric detection and PLS can evaluate the ions concentration accurately. The work proposed here is an interesting and promising attempt for the trace ions determination in water samples and will have much more applied field.
Saber, Amr L
2009-04-15
An instrumental setup including on-line solid phased extraction coupled to capillary liquid chromatography-electrospray ionization-mass spectrometry (SPE-capLC-ESI-MS) has been constructed to improve the sensitivity for quantification of fluoxetine hydrochloride in human plasma. Prior to injection, 0.5 mL of plasma spiked with metronidazole (internal standard) was mixed with ammonium formate buffer for effective chloroform liquid-liquid extraction. The method was validated in the range 5-60 ng mL(-1) fluoxetine, yielding a correlation coefficient of 0.999 (r(2)). The within-assay and between-assay precisions were between (8.5 and 11%) and (6.6 and 7.5%), respectively. The method was used to determine the amount of fluoxetine in a healthy male 14 h after an intake of one capsule of the antidepressant and anorectic Flutin, which contains 20mg fluoxetine per each capsule. Fluoxetine was detected, and the concentration was calculated to 9.0 ng mL(-1) plasma. In the preliminary experiments, conventional LC-UV instrumentation was employed. However, it was found that employing a capillary column with an inner diameter of (0.3mm I.D. x 50 mm, Zorbax C(18)) increased the sensitivity by a factor of approximately 100, when injecting the same mass of analyte. Incorporating an easily automated C(18) reversed phase column switching system with SPE (1.0mm I.D. x 5.0mm, 5 microm) made it possible to inject up to 100 microL of solution, and the total analysis time was 5.5 min.
Guo, Yugao; Zhao, He; Han, Yelin; Liu, Xia; Guan, Shan; Zhang, Qingyin; Bian, Xihui
2017-02-15
A simultaneous spectrophotometric determination method for trace heavy metal ions based on solid-phase extraction coupled with partial least squares approaches was developed. In the proposed method, trace metal ions in aqueous samples were adsorbed by cation exchange fibers and desorbed by acidic solution from the fibers. After the ion preconcentration process, the enriched solution was detected by ultraviolet and visible spectrophotometer (UV-Vis). Then, the concentration of heavy metal ions were quantified by analyzing ultraviolet and visible spectrum with the help of partial least squares (PLS) approaches. Under the optimal conditions of operation time, flow rate and detection parameters, the overlapped absorption peaks of mixed ions were obtained. The experimental data showed that the concentration, which can be calculated through chemometrics method, of each metal ion increased significantly. The heavy metal ions can be enriched more than 80-fold. The limits of detection (LOD) for the target analytes of copper ions (Cu 2+ ), cobalt ions (Co 2+ ) and nickel ions (Ni 2+ ) mixture was 0.10μgL -1 , 0.15μgL -1 and 0.13μgL -1 , respectively. The relative standard deviations (RSD) were less than 5%. The performance of the solid-phase extraction can enrich the ions efficiently and the combined method of spectrophotometric detection and PLS can evaluate the ions concentration accurately. The work proposed here is an interesting and promising attempt for the trace ions determination in water samples and will have much more applied field. Copyright © 2016 Elsevier B.V. All rights reserved.
Chávez-Moreno, C A; Guzmán-Mar, J L; Hinojosa-Reyes, L; Hernández-Ramírez, A; Ferrer, L; Cerdà, V
2012-07-01
Simultaneous determination of three herbicides (dicamba, 2,4-D, and atrazine) has been achieved by on-line solid-phase extraction (SPE) coupled to multisyringe chromatography (MSC) with UV detection. The preconcentration conditions were optimized; a preconcentration flow rate of 0.5 mL min(-1) and elution at 0.8 mL min(-1) were the optimum conditions. A C(18) (8 mm i.d.) membrane extraction disk conditioned with 0.3 mol L(-1) HCl in 0.5% MeOH was used. A 3-mL sample was preconcentrated, then eluted with 0.43 mL 40:60 water-MeOH. A C(18) monolithic column (25 mm × 4.6 mm) was used for chromatographic separation. Separation of the three compounds was achieved in 10 min by use of 0.01% aqueous acetic acid-MeOH (60:40) as mobile phase at a flow rate of 0.8 mL min(-1). The limits of detection (LOD) were 13, 57, and 22 μg L(-1) for dicamba, 2,4-D, and atrazine, respectively. The sampling frequency was three analyses per hour, and each analysis consumed only 7.3 mL solvent. The method was applied to spiked water samples, and recovery between 85 and 112% was obtained. Recovery was significantly better than in the conventional HPLC-UV method. These results indicated the reliability and accuracy of this flow-based method. This is the first time this family of herbicides has been simultaneously analyzed by on-line SPE-MSC using a monolithic column.
Bandforuzi, Samereh Ranjbar; Hadjmohammadi, Mohammad Reza
2018-08-03
The extraction of phthalate esters (PEs) from aqueous matrices using two-phase solvent bar microextraction by organic micellar phase was investigated. A short hollow fiber immobilized with reverse micelles of Brij 35 surfactant in 1-octanol was served as the solvent bar for microextraction. Experimental results show that the extraction efficiency were much higher using two-phase solvent bar microextraction based on non-ionic surfactant than conventional two-phase solvent bar microextraction because of a positive effect of surfactant-containing extraction phase in promoting the partition process by non-ionic intermolecular forces such as polar and hydrophobicity interactions. The nature of the extraction solvent, type and concentration of non-ionic surfactant, extraction time, sample pH, temperature, stirring rate and ionic strength were the effecting parameters which optimized to obtain the highest extraction recovery. Analysis of recovered analytes was carried out with high performance liquid chromatography coupled with ultraviolet detection (HPLC-UV). Under the optimum conditions, linearity was observed in the range of 1-800 ng mL -1 for dimethylphthalate (DMP) and 0.5-800 ng mL -1 for diethylphthalate (DEP) and di-n-butyl phthalate (DBP) with correlation determination values above 0.99 for them. The limits of detection and quantification were ranged from 0.012 to 0.03 ng mL -1 and 0.04-0.1 ng mL -1 , respectively. The ranges of intra-day and inter-day RSD (n = 3) at 20 ng mL -1 of PEs were 1.8-2.1% and 2.1-2.6%, respectively. Results showed that developed method can be a very powerful, innovative and promising sample preparation technique in PEs analysis from environmental and drinking water samples. Copyright © 2018. Published by Elsevier B.V.
Shamsipur, Mojtaba; Yazdanfar, Najmeh; Ghambarian, Mahnaz
2016-08-01
In this work, an effective preconcentration method for the extraction and determination of traces of multi-residue pesticides was developed using solid-phase extraction (SPE) coupled with dispersive liquid-liquid microextraction and gas chromatography-mass spectrometry (GC-MS). Variables affecting the performance of both extraction steps such as type and volume of elution and extraction solvents, breakthrough volume, salt addition, extraction time were thoroughly investigated. The proposed method resulted in good linearities (R(2)>0.9915) over the ranges of 1-10,000ngkg(-1), limits of detection (LODs) in the range of 0.5-1.0ngkg(-1) at S/N=3, and precision of RSD% of ⩽11.8. Under optimal conditions, the preconcentration factors were obtained in the range of 2362-10,593 for 100mL sample solutions. Comparison of the proposed method with other ones demonstrated that SPE-DLLME method provides higher extraction efficiency and larger preconcentration factor for determination of pesticides residues. Further, it is simple, inexpensive, highly sensitive, and can be successfully applied to separation, preconcentration and determination of the pesticides (and other noxious materials) in different real food samples. Copyright © 2016 Elsevier Ltd. All rights reserved.
System and method for cooling a superconducting rotary machine
Ackermann, Robert Adolf [Schenectady, NY; Laskaris, Evangelos Trifon [Schenectady, NY; Huang, Xianrui [Clifton Park, NY; Bray, James William [Niskayuna, NY
2011-08-09
A system for cooling a superconducting rotary machine includes a plurality of sealed siphon tubes disposed in balanced locations around a rotor adjacent to a superconducting coil. Each of the sealed siphon tubes includes a tubular body and a heat transfer medium disposed in the tubular body that undergoes a phase change during operation of the machine to extract heat from the superconducting coil. A siphon heat exchanger is thermally coupled to the siphon tubes for extracting heat from the siphon tubes during operation of the machine.
Development of green extraction processes for Nannochloropsis gaditana biomass valorization.
Sánchez-Camargo, Andrea Del Pilar; Pleite, Natalia; Mendiola, José Antonio; Cifuentes, Alejandro; Herrero, Miguel; Gilbert-López, Bienvenida; Ibáñez, Elena
2018-04-23
In the present work, the valorization of Nannochloropsis gaditana biomass is proposed within the concept of biorefinery. To this aim, high-pressure homogenization (HPH) was used to break down the strong cell wall and supercritical fluid extraction (SFE) with pure CO 2 was applied as a first step to extract valuable compounds (such as non-polar lipids and pigments). Extraction of the remaining residue for the recovery of bioactive compounds was studied by means of an experimental design based on response surface methodology (RSM) employing pressurized liquid extraction (PLE) with green solvents such as water and ethanol. Optimum extract was achieved with pure ethanol at 170°C for 20 min, providing an important antioxidant capacity (0.72 ± 0.03 mmol trolox eq g -1 extract). Complete chemical characterization of the optimum extract was carried out by using different chromatographic methods such as reverse-phase high-performance liquid chromatography with diode array detection (RP-HPLC-DAD), normal-phase HPLC with evaporative light scattering detection (NP-HPLC-ELSD) and gas chromatography coupled to mass spectrometry detection (GC-MS); carotenoids (e.g. violaxanthin), chlorophylls and polar lipids were the main compounds observed while palmitoleic, palmitic, myristic acids and the polyunsaturated eicosapentanoic (EPA) acid were the predominant fatty acids in all PLE extracts. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Hsieh, Fushing; Hsueh, Chih-Hsin; Heitkamp, Constantin; Matthews, Mark
2016-01-01
Multiple datasets of two consecutive vintages of replicated grape and wines from six different deficit irrigation regimes are characterized and compared. The process consists of four temporal-ordered signature phases: harvest field data, juice composition, wine composition before bottling and bottled wine. A new computing paradigm and an integrative inferential platform are developed for discovering phase-to-phase pattern geometries for such characterization and comparison purposes. Each phase is manifested by a distinct set of features, which are measurable upon phase-specific entities subject to the common set of irrigation regimes. Throughout the four phases, this compilation of data from irrigation regimes with subsamples is termed a space of media-nodes, on which measurements of phase-specific features were recoded. All of these collectively constitute a bipartite network of data, which is then normalized and binary coded. For these serial bipartite networks, we first quantify patterns that characterize individual phases by means of a new computing paradigm called "Data Mechanics". This computational technique extracts a coupling geometry which captures and reveals interacting dependence among and between media-nodes and feature-nodes in forms of hierarchical block sub-matrices. As one of the principal discoveries, the holistic year-factor persistently surfaces as the most inferential factor in classifying all media-nodes throughout all phases. This could be deemed either surprising in its over-arching dominance or obvious based on popular belief. We formulate and test pattern-based hypotheses that confirm such fundamental patterns. We also attempt to elucidate the driving force underlying the phase-evolution in winemaking via a newly developed partial coupling geometry, which is designed to integrate two coupling geometries. Such partial coupling geometries are confirmed to bear causal and predictive implications. All pattern inferences are performed with respect to a profile of energy distributions sampled from network bootstrapping ensembles conforming to block-structures specified by corresponding hypotheses.
Hsieh, Fushing; Hsueh, Chih-Hsin; Heitkamp, Constantin; Matthews, Mark
2016-01-01
Multiple datasets of two consecutive vintages of replicated grape and wines from six different deficit irrigation regimes are characterized and compared. The process consists of four temporal-ordered signature phases: harvest field data, juice composition, wine composition before bottling and bottled wine. A new computing paradigm and an integrative inferential platform are developed for discovering phase-to-phase pattern geometries for such characterization and comparison purposes. Each phase is manifested by a distinct set of features, which are measurable upon phase-specific entities subject to the common set of irrigation regimes. Throughout the four phases, this compilation of data from irrigation regimes with subsamples is termed a space of media-nodes, on which measurements of phase-specific features were recoded. All of these collectively constitute a bipartite network of data, which is then normalized and binary coded. For these serial bipartite networks, we first quantify patterns that characterize individual phases by means of a new computing paradigm called “Data Mechanics”. This computational technique extracts a coupling geometry which captures and reveals interacting dependence among and between media-nodes and feature-nodes in forms of hierarchical block sub-matrices. As one of the principal discoveries, the holistic year-factor persistently surfaces as the most inferential factor in classifying all media-nodes throughout all phases. This could be deemed either surprising in its over-arching dominance or obvious based on popular belief. We formulate and test pattern-based hypotheses that confirm such fundamental patterns. We also attempt to elucidate the driving force underlying the phase-evolution in winemaking via a newly developed partial coupling geometry, which is designed to integrate two coupling geometries. Such partial coupling geometries are confirmed to bear causal and predictive implications. All pattern inferences are performed with respect to a profile of energy distributions sampled from network bootstrapping ensembles conforming to block-structures specified by corresponding hypotheses. PMID:27508416
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gevorkyan, S. R.; Sissakian, A. N.; Tarasov, A. V.
The Fermi-Watson theorem is generalized to the case of two coupled channels with different masses and applied to final-state interaction inK{sub e4} decays. The impact of the considered effect on the phase of {pi}{pi} scattering is estimated and it is shown that it can be crucial for the scattering length extraction from experimental data on K{sub e4} decays.
Yao, Tian; Yao, Shun
2017-01-20
A novel organic magnetic ionic liquid based on guanidinium cation was synthesized and characterized. A new method of magnetic ionic liquid aqueous two-phase system (MILATPs) coupled with high-performance liquid chromatography (HPLC) was established to preconcentrate and determine trace amount of chloramphenicol (CAP) in water environment for the first time. In the absence of volatile organic solvents, MILATPs not only has the excellent properties of rapid extraction, but also exhibits a response to an external magnetic field which can be applied to assist phase separation. The phase behavior of MILATPs was investigated and phase equilibrium data were correlated by Merchuk equation. Various influencing factors on CAP recovery were systematically investigated and optimized. Under the optimal conditions, the preconcentration factor was 147.2 with the precision values (RSD%) of 2.42% and 4.45% for intra-day (n=6) and inter-day (n=6), respectively. The limit of detection (LOD) and limit of quantitation (LOQ) were 0.14ngmL -1 and 0.42ngmL -1 , respectively. Fine linear range of 12.25ngmL -1 -2200ngmL -1 was obtained. Finally, the validated method was successfully applied for the analysis of CAP in some environmental waters with the recoveries for the spiked samples in the acceptable range of 94.6%-99.72%. Hopefully, MILATPs is showing great potential to promote new development in the field of extraction, separation and pretreatment of various biochemical samples. Copyright © 2016 Elsevier B.V. All rights reserved.
Sun, Guangying; Liu, Yanfang; Ahat, Hasanjan; Shen, Aijin; Liang, Xinmiao; Xue, Xingya; Luo, Yuqin; Yang, Jian; Liu, Zhao-Sheng; Aisa, Haji Akber
2017-07-07
In this study, "two dimensional" molecularly imprinted solid-phase extraction (2D-MIP-SPE) of semi-preparative grade was constructed to fast purify ellagitannins in pomegranate husk extract with the help of crystallization and reverse-phase liquid chromatgoraphy (RPLC). Ellagic acid and punicalagin imprinted polymers were synthesized in batch mode and two semi-preparative MIP-SPE columns were individually packed. After investigaing "functional complementation", 2D-MIP-SPE was constructed using ellagic acid MIP and punicalagin MIP-SPE as the first and second dimension, respectively. Then, pomegranate husk extract was fast divided into four fractions individually enriching in ellagic acid, granatin A, punicalagin and ellagic acid glucoside by 2D-MIP-SPE. With the aid of crystallization and RPLC, ellagic acid (13.5mg) and punicalagin (53.4mg) were fast obtained in 30min. Ellagic acid glucoside was purified to the purity near 100% with a recovery of 86.1%. Granatin A (92%) was directly obtained by 2D-MIP-SPE with the recovery of 81.8%. All above indicated that 2D-MIP-SPE was highly efficient in natural product purification. The concept of "functional complementation" was expected to be a useful tool in the construction of 2D-MIP-SPE. Copyright © 2017 Elsevier B.V. All rights reserved.
Aleksa, Katarina; Walasek, Paula; Fulga, Netta; Kapur, Bhushan; Gareri, Joey; Koren, Gideon
2012-05-10
The analysis of pediatric and adult hair is a useful non-invasive biomarker to effectively detect long term exposure to various xenobiotics, specifically drugs of abuse such as cocaine, opiates and amphetamines. Very often individuals are using, or are exposed to multiple drugs simultaneously and therefore it is important to be able to detect them in the same analysis. We have developed a sensitive and specific solid phase micro extraction (SPME) coupled with gas chromatography mass spectrometry (GC/MS) to detect 17 different analytes in hair using a single extraction method. Five milligrams of hair is extracted overnight, subjected to solid phase extraction (SPE) and then to SPME-GC/MS. The aimed analytes include amphetamine, methamphetamine, MDA, MDMA, cocaine, benzoylecognine, norcocaine, cocaethylene, methadone, codeine, morphine, 6-AM, oxycodone, oxymorphone, hydrocodone, hydromorphone and meperidone. The following are the LOD of the various drugs: 0.2ng/mg hair for amphetamine, methamphetamine, MDA, MDMA, morphine, codeine, 6-AM, oxycodone, oxymorphone, hydromorphone, hydrocodone, meperidine and 0.13ng/mg hair for cocaine, benzoylecognine, cocaethylene, norcocaine and methadone. This GC/MS method is sensitive and specific to detect the presence of these 17 analytes in as little as 5mg of hair and is especially useful for newborn and child hair analysis where the amount of hair is often very limited. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.
Determination of volatile organic hydrocarbons in water samples by solid-phase dynamic extraction.
Jochmann, Maik A; Yuan, Xue; Schmidt, Torsten C
2007-03-01
In the present study a headspace solid-phase dynamic extraction method coupled to gas chromatography-mass spectrometry (HS-SPDE-GC/MS) for the trace determination of volatile halogenated hydrocarbons and benzene from groundwater samples was developed and evaluated. As target compounds, benzene as well as 11 chlorinated and brominated hydrocarbons (vinyl chloride, dichloromethane, cis-1,2-dichloroethylene, trans-1,2-dichloroethylene, carbon tetrachloride, chloroform, trichloroethylene, tetrachloroethylene, bromoform) of environmental and toxicological concern were included in this study. The analytes were extracted using a SPDE needle device, coated with a poly(dimethylsiloxane) with 10% embedded activated carbon phase (50-microm film thickness and 56-mm film length) and were analyzed by GC/MS in full-scan mode. Parameters that affect the extraction yield such as extraction and desorption temperature, salting-out, extraction and desorption flow rate, extraction volume and desorption volume, the number of extraction cycles, and the pre-desorption time have been evaluated and optimized. The linearity of the HS-SPDE-GC/MS method was established over several orders of magnitude. Method detection limits (MDLs) for the compounds investigated ranged between 12 ng/L for cis-dichloroethylene and trans-dichloroethylene and 870 ng/L for vinyl chloride. The method was thoroughly validated, and the precision at two concentration levels (0.1 mg/L and a concentration 5 times above the MDL) was between 3.1 and 16% for the analytes investigated. SPDE provides high sensitivity, short sample preparation and extraction times and a high sample throughput because of full automation. Finally, the applicability to real environmental samples is shown exemplarily for various groundwater samples from a former waste-oil recycling facility. Groundwater from the site showed a complex contamination with chlorinated volatile organic compounds and aromatic hydrocarbons.
Amoli-Diva, Mitra; Taherimaslak, Zohreh; Allahyari, Mehdi; Pourghazi, Kamyar; Manafi, Mohammad Hanif
2015-03-01
An efficient, simple and fast low-density solvent based dispersive liquid-liquid microextraction (LDS-DLLME) followed by vortex-assisted dispersive solid phase extraction (VA-D-SPE) has been developed as a new approach for extraction and preconcentration of aflatoxin M1 in milk samples prior to its micelle enhanced spectrofluorimetic determination. In this LDS-DLLME coupled VA-D-SPE method, milk samples were first treated with methanol/water (80:20, v/v) after removing the fat layer. This solvent was directly used as the dispersing solvent in DLLME along with using 1-heptanol (as a low-density solvent with respect to water) as the extracting solvent. In VA-D-SPE approach, hydrophobic oleic acid modified Fe3O4 nanoparticles were used to retrieve the analyte from the DLLME step. It is considerably that the target of VA-D-SPE was 1-heptanol rather than the aflatoxin M1 directly. The main parameters affecting the efficiency of LDS-DLLME and VA-D-SPE procedures and signal enhancement of aflatoxin M1 were investigated and optimized. Under the optimum conditions, the method was linear in the range from 0.02 to 200 µg L(-1) with the correlation coefficient (R(2)) of 0.9989 and detection limit of 13 ng L(-1). The intra-day precision was 2.9 and 4.3% and the inter-day precision was 2.1 and 3.3% for concentration of 2 and 50 µg L(-1) respectively. The developed method was applied for extraction and preconcentration of AFM1 in three commercially available milk samples and the results were compared with the official AOAC method. Copyright © 2014 Elsevier B.V. All rights reserved.
Li, Zhongping; Wang, Xibin; Li, Liwu; Zhang, Mingjie; Tao, Mingxin; Xing, Lantian; Cao, Chunhui; Xia, Yanqing
2014-11-01
Compound specific isotope analysis (CSIA) of normal-level hydrocarbons (C 1 -C 4 ) in natural gas is often successfully used in natural gas origin identification and classification, but little progress so far has been made for trace level hydrocarbons (C 5 -C 14 ) in natural gas. In this study, we developed a method for rapid analysis of carbon isotopic ratios for trace hydrocarbons in natural gas samples. This method can be described as a combined approach characterized by solid phase micro-extraction (SPME) technique coupled to gas chromatography isotope ratio mass spectrometry (GC/IRMS). In this study, the CAR-PDMS fiber was chosen as the SPME adsorptive material after comparative experiments with other four fibers, and the parameters, including equilibration time, extraction temperature and desorption time, for efficient extraction of trace hydrocarbons were systematically optimized. The results showed the carbon isotopic fractionation was not observed as a function of equilibration time and extraction temperature. And the δ 13 C signatures determined by SPME-GC/IRMS were in good agreement with the known δ 13 C values of C 5 -C 14 measured by GC-IRMS, and the accuracy is generally within ±0.5‰. Five natural gas samples were analyzed using this method, and the δ 13 C values for C 5 -C 14 components were obtained with satisfied repeatability. The SPME-GC/IRMS approach fitted with CAR-PDMS fiber is well suited for the preconcentration of trace hydrocarbons and provides so far the most reliable carbon isotopic analysis for trace compounds in natural gas. Published by Elsevier B.V.
NASA Astrophysics Data System (ADS)
Cao, Yupin; Yan, Lizhen; Huang, Hongli; Deng, Biyang
2016-08-01
A new method for determination of selenium species in radix puerariae was described. The method consists of sample enrichment with 5-sulfosalicylic acid (SSA)-functionalized silica-coated magnetic nanoparticles (SMNPs), high performance liquid chromatography (HPLC) separation, and online detection using inductively coupled plasma mass spectrometry (ICP-MS). The selenium species were extracted using ultrasonic extraction system with a mixture of protease K and lipase. The SSA-SMNPs were used to enrich trace amounts of selenite [Se(IV)], selenate [Se(VI)], selenomethionine (SeMet), and selenocystine (SeCys2) from lower selenium containing samples. Under the optimal conditions, the limits of detection (3σ) for SeCys2, Se(IV), SeMet and Se(VI) were observed as 0.0023, 0.0015, 0.0043, and 0.0016 ng mL- 1, respectively. The RSD values (n = 6) of method for intraday were observed between 0.5% and 0.9%. The RSD values of method for interday were less than 1.3%. The linear concentration ranges for SeCys2, Se(IV), SeMet and Se(VI) were 0.008-1000, 0.005-200, 0.015-500 and 0.006-200 ng mL- 1, respectively. The detection limits of this method were improved by 10 times due to the enrichment with the SSA-SMNP extraction. The contents of SeCys2, Se(IV), SeMet, and Se(VI) in radix puerariae were determined as 0.0140, 0.171, 0.0178, and 0.0344 μg g- 1, respectively. The recoveries were in the range of 95.6%-99.4% and the RSDs (n = 6) of recoveries were less than 1.5%.
Murakami, Tomonori; Kawasaki, Takao; Takemura, Akira; Fukutsu, Naoto; Kishi, Naoyuki; Kusu, Fumiyo
2008-10-24
Rapid and unambiguous identification of three degradation products (DP-1, DP-2 and DP-3) found in heat-stressed loxoprofen sodium adhesive tapes (Loxonin tapes) was achieved by LC-MS and dynamic pressurized liquid extraction (PLE)-solid-phase extraction (SPE) coupled to LC-NMR without complicated isolation or purification processes. The molecular formulae of the degradation products were determined by accurate mass measurements and product ion analyses and on-line hydrogen/deuterium (H/D) exchange experiments provided information about changes in the degradation of loxoprofen. To compensate for the low sensitivity of NMR, on-line dynamic PLE-SPE was employed and higher concentrations of degradation products trapped on the SPE column were afforded in a shorter time than they would be in such time-consuming sample preparations as pre-concentration after extraction. The loop-storage procedure was used in the LC-NMR analysis to allow the acquisition of the (1)H spectra of the three degradation products in one chromatographic run without affecting the peak separation and to avoid the carry-over of previously eluted DP-1 of high concentration by washing the NMR detection cell prior to the measurement of the DP-2 spectrum. Based on the resulting (1)H NMR spectra in combination with the MS results, DP-1 was successfully identified as an oxidation product having an oxodicarboxylic acid structure formed by the cleavage of the cyclopentanone ring of loxoprofen, DP-2 as a cyclopentanone ring-hydroxylated loxoprofen and DP-3 as a loxoprofen l-menthol ester.
Burkhardt, M.R.; Zaugg, S.D.; Burbank, T.L.; Olson, M.C.; Iverson, J.L.
2005-01-01
Polycyclic aromatic hydrocarbons (PAH) are recognized as environmentally relevant for their potential adverse effects on human and ecosystem health. This paper describes a method to determine the distribution of PAH and alkylated homolog groups in sediment samples. Pressurized liquid extraction (PLE), coupled with solid-phase extraction (SPE) cleanup, was developed to decrease sample preparation time, to reduce solvent consumption, and to minimize background interferences for full-scan GC-MS analysis. Recoveries from spiked Ottawa sand, environmental stream sediment, and commercially available topsoil, fortified at 1.5-15 ??g per compound, averaged 94.6 ?? 7.8%, 90.7 ?? 5.8% and 92.8 ?? 12.8%, respectively. Initial method detection limits for single-component compounds ranged from 20 to 302 ??g/kg, based on 25 g samples. Results from 28 environmental sediment samples, excluding homologs, show 35 of 41 compounds (85.4%) were detected in at least one sample with concentrations ranging from 20 to 100,000 ??g/kg. The most frequently detected compound, 2,6-dimethylnaphthalene, was detected in 23 of the 28 (82%) environmental samples with a concentration ranging from 15 to 907 ??g/kg. The results from the 28 environmental sediment samples for the homolog series showed that 27 of 28 (96%) samples had at least one homolog series present at concentrations ranging from 20 to 89,000 ??g/kg. The most frequently detected homolog series, C2-alkylated naphthalene, was detected in 26 of the 28 (93%) environmental samples with a concentration ranging from 25 to 3900 ??g/kg. Results for a standard reference material using dichloromethane Soxhlet-based extraction also are compared. ?? 2005 Elsevier B.V. All rights reserved.
Rahimi, Marzieh; Hashemi, Payman; Nazari, Fariba
2014-05-15
A cold column trapping-cloud point extraction (CCT-CPE) method coupled to high performance liquid chromatography (HPLC) was developed for preconcentration and determination of curcumin in human urine. A nonionic surfactant, Triton X-100, was used as the extraction medium. In the proposed method, a low surfactant concentration of 0.4% v/v and a short heating time of only 2min at 70°C were sufficient for quantitative extraction of the analyte. For the separation of the extraction phase, the resulted cloudy solution was passed through a packed trapping column that was cooled to 0 °C. The temperature of the CCT column was then increased to 25°C and the surfactant rich phase was desorbed with 400μL ethanol to be directly injected into HPLC for the analysis. The effects of different variables such as pH, surfactant concentration, cloud point temperature and time were investigated and optimum conditions were established by a central composite design (response surface) method. A limit of detection of 0.066mgL(-1) curcumin and a linear range of 0.22-100mgL(-1) with a determination coefficient of 0.9998 were obtained for the method. The average recovery and relative standard deviation for six replicated analysis were 101.0% and 2.77%, respectively. The CCT-CPE technique was faster than a conventional CPE method requiring a lower concentration of the surfactant and lower temperatures with no need for the centrifugation. The proposed method was successfully applied to the analysis of curcumin in human urine samples. Copyright © 2014 Elsevier B.V. All rights reserved.
Evolution of cardiorespiratory interactions with age
Iatsenko, D.; Bernjak, A.; Stankovski, T.; Shiogai, Y.; Owen-Lynch, P. J.; Clarkson, P. B. M.; McClintock, P. V. E.; Stefanovska, A.
2013-01-01
We describe an analysis of cardiac and respiratory time series recorded from 189 subjects of both genders aged 16–90. By application of the synchrosqueezed wavelet transform, we extract the respiratory and cardiac frequencies and phases with better time resolution than is possible with the marked events procedure. By treating the heart and respiration as coupled oscillators, we then apply a method based on Bayesian inference to find the underlying coupling parameters and their time dependence, deriving from them measures such as synchronization, coupling directionality and the relative contributions of different mechanisms. We report a detailed analysis of the reconstructed cardiorespiratory coupling function, its time evolution and age dependence. We show that the direct and indirect respiratory modulations of the heart rate both decrease with age, and that the cardiorespiratory coupling becomes less stable and more time-variable. PMID:23858485
Evolution of cardiorespiratory interactions with age.
Iatsenko, D; Bernjak, A; Stankovski, T; Shiogai, Y; Owen-Lynch, P J; Clarkson, P B M; McClintock, P V E; Stefanovska, A
2013-08-28
We describe an analysis of cardiac and respiratory time series recorded from 189 subjects of both genders aged 16-90. By application of the synchrosqueezed wavelet transform, we extract the respiratory and cardiac frequencies and phases with better time resolution than is possible with the marked events procedure. By treating the heart and respiration as coupled oscillators, we then apply a method based on Bayesian inference to find the underlying coupling parameters and their time dependence, deriving from them measures such as synchronization, coupling directionality and the relative contributions of different mechanisms. We report a detailed analysis of the reconstructed cardiorespiratory coupling function, its time evolution and age dependence. We show that the direct and indirect respiratory modulations of the heart rate both decrease with age, and that the cardiorespiratory coupling becomes less stable and more time-variable.
Wang, Zhibing; He, Mengyu; Jiang, Chunzhu; Zhang, Fengqing; Du, Shanshan; Feng, Wennan; Zhang, Hanqi
2015-12-01
Matrix solid-phase dispersion coupled with homogeneous ionic liquid microextraction was developed and applied to the extraction of some sulfonamides, including sulfamerazine, sulfamethazine, sulfathiazole, sulfachloropyridazine, sulfadoxine, sulfisoxazole, and sulfaphenazole, in animal tissues. High-performance liquid chromatography was applied to the separation and determination of the target analytes. The solid sample was directly treated by matrix solid-phase dispersion and the eluate obtained was treated by homogeneous ionic liquid microextraction. The ionic liquid was used as the extraction solvent in this method, which may result in the improvement of the recoveries of the target analytes. To avoid using organic solvent and reduce environmental pollution, water was used as the elution solvent of matrix solid-phase dispersion. The effects of the experimental parameters on recoveries, including the type and volume of ionic liquid, type of dispersant, ratio of sample to dispersant, pH value of elution solvent, volume of elution solvent, amount of salt in eluate, amount of ion-pairing agent (NH4 PF6 ), and centrifuging time, were evaluated. When the present method was applied to the analysis of animal tissues, the recoveries of the analytes ranged from 85.4 to 118.0%, and the relative standard deviations were lower than 9.30%. The detection limits for the analytes were 4.3-13.4 μg/kg. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
A novel method to measure isotopic labeled gas-phase nitrous acid (HO15NO) in biogeochemical studies
NASA Astrophysics Data System (ADS)
Wu, Dianming; Kampf, Christopher; Pöschl, Ulrich; Oswald, Robert; Cui, Junfang; Ermel, Michael; Hu, Chunsheng; Trebs, Ivonne; Sörgel, Matthias
2014-05-01
We developed a new method (gas-phase stripping-derivatization coupled to LC-MS) to measure the 15N atom percent excess (APE) of HONO in the gas-phase. Gaseous HONO is quantitatively collected and transferred to an azo dye by the well-known Griess reaction in the Long Path Absorption Photometer (LOPAP). The reaction solutions containing the dye are collected at the outflow of the LOPAP, purified by solid-phase extraction and analyzed using high performance liquid chromatography coupled to mass spectrometry (HPLC-MS). The unlabeled azo dye (C18H19O2N5S) with a monoisotopic molecular mass of 369.41 g mol-1 can be detected as its protonated molecular ion ([M+H+], M) by HPLC-MS at a retention time of 2.8 min. Due to the natural isotope distribution M + 0, M + 1, M + 2, and M + 3 ions were considered for the calculation of the 15N APE. The optimal working range was found to be between 20 and 50% for the 15N/14N ratio. The optimum pH and solvents for extraction by SPE and potential interferences are discussed. The method has been applied for the measurement of HO15NO emissions from soil in a dynamic chamber with and without spiking 15N labeled urea. Our results confirm biogenic HONO emissions from soil as HO15NO was measured after addition of 15N urea.
Amvrazi, Elpiniki G; Albanis, Triantafyllos A
2008-07-23
The processing factors (pesticide concentration found in olive oil/pesticide concentration found in olives) of azinphos methyl, chlorpyrifos, lambda-cyhalothrin, deltamethrin, diazinon, dimethoate, endosulfan, and fenthion were determined in olive oil production process in various laboratory-scale olive oil extractions based on three- or two-phase centrifugation systems in comparison with samples collected during olive oil extractions in conventional olive mills located at different olive oil production areas in Greece. Pesticide analyses were performed using a multiresidue method developed in our laboratory for the determination of different insecticides and herbicides in olive oil by solid-phase extraction techniques coupled to gas chromatography detection (electron capture detection and nitrogen phosphorus detection), optimized, and validated for olive fruits sample preparation. Processing factors were found to vary among the different pesticides studied. Water addition in the oil extraction procedure (as in a three-phase centrifugation system) was found to decrease the processing factors of dimethoate, alpha-endosulfan, diazinon, and chlorpyrifos, whereas those of fenthion, azinphos methyl, beta-endosulfan, lambda-cyhalothrin, and deltamethrin residues were not affected. The water content of olives processed was found to proportionally affect pesticide processing factors. Fenthion sulfoxide and endosulfan sulfate were the major metabolites of fenthion and endosulfan, respectively, that were detected in laboratory-produced olive oils, but only the concentration of fenthion sulfoxide was found to increase with the increase of water addition in the olive oil extraction process.
Qi, Xue; Gao, Shuang; Ding, Guosheng; Tang, An-Na
2017-01-01
A facile, rapid and selective magnetic dispersed solid-phase extraction (dSPE) method for the extraction and enrichment of Cr (VI) prior to flame atomic absorption spectrometry (AAS) was introduced. For highly selective and efficient extraction, magnetic Cr (VI)-imprinted nanoparticles (Fe 3 O 4 @ Cr (VI) IIPs) were prepared by hyphenating surface ion-imprinted with sol-gel techniques. In the preparation process, chromate (Cr(VI)) was used as the template ion; vinylimidazole and 3-aminopropyltriethoxysilane were selected as organic functional monomer and co-monomer respectively. Another reagent, methacryloxypropyltrimethoxysilane was adopted as coupling agent to form the stable covalent bonding between organic and inorganic phases. The effects of various parameters on the extraction efficiency, such as pH of sample solution, the amount of adsorbent, extraction time, the type and concentration of eluent were systematically investigated. Furthermore, the thermodynamic and kinetic properties of the adsorption process were studied to explore the internal adsorption mechanism. Under optimized conditions, the preconcentration factor, limit of detection and linear range of the established dSPE-AAS method for Cr (VI) were found to be 98, 0.29μgL -1 and 4-140μgL -1 , respectively. The developed method was also successfully applied to the analysis of Cr (VI) in different water samples with satisfactory results, proving its reliability and feasibility in real sample analysis. Copyright © 2016 Elsevier B.V. All rights reserved.
Jiménez-Díaz, I; Vela-Soria, F; Rodríguez-Gómez, R; Zafra-Gómez, A; Ballesteros, O; Navalón, A
2015-09-10
In the present work, a review of the analytical methods developed in the last 15 years for the determination of endocrine disrupting chemicals (EDCs) in human samples related with children, including placenta, cord blood, amniotic fluid, maternal blood, maternal urine and breast milk, is proposed. Children are highly vulnerable to toxic chemicals in the environment. Among these environmental contaminants to which children are at risk of exposure are EDCs -substances able to alter the normal hormone function of wildlife and humans-. The work focuses mainly on sample preparation and instrumental techniques used for the detection and quantification of the analytes. The sample preparation techniques include, not only liquid-liquid extraction (LLE) and solid-phase extraction (SPE), but also modern microextraction techniques such as extraction with molecular imprinted polymers (MIPs), stir-bar sorptive extraction (SBSE), hollow-fiber liquid-phase microextraction (HF-LPME), dispersive liquid-liquid microextraction (DLLME), matrix solid phase dispersion (MSPD) or ultrasound-assisted extraction (UAE), which are becoming alternatives in the analysis of human samples. Most studies focus on minimizing the number of steps and using the lowest solvent amounts in the sample treatment. The usual instrumental techniques employed include liquid chromatography (LC), gas chromatography (GC) mainly coupled to tandem mass spectrometry. Multiresidue methods are being developed for the determination of several families of EDCs with one extraction step and limited sample preparation. Copyright © 2015 Elsevier B.V. All rights reserved.
González, Natalia; Grünhut, Marcos; Šrámková, Ivana; Lista, Adriana G; Horstkotte, Burkhard; Solich, Petr; Sklenářová, Hana; Acebal, Carolina C
2018-02-01
A fully automated spectrophotometric method based on flow-batch analysis has been developed for the determination of clenbuterol including an on-line solid phase extraction using a molecularly imprinted polymer (MIP) as the sorbent. The molecularly imprinted solid phase extraction (MISPE) procedure allowed analyte extraction from complex matrices at low concentration levels and with high selectivity towards the analyte. The MISPE procedure was performed using a commercial MIP cartridge that was introduced into a guard column holder and integrated in the analyzer system. Optimized parameters included the volume of the sample, the type and volume of the conditioning and washing solutions, and the type and volume of the eluent. Quantification of clenbuterol was carried out by spectrophotometry after in-system post-elution analyte derivatization based on azo-coupling using N- (1-Naphthyl) ethylenediamine as the coupling agent to yield a red-colored compound with maximum absorbance at 500nm. Both the chromogenic reaction and spectrophotometric detection were performed in a lab-made flow-batch mixing chamber that replaced the cuvette holder of the spectrophotometer. The calibration curve was linear in the 0.075-0.500mgL -1 range with a correlation coefficient of 0.998. The precision of the proposed method was evaluated in terms of the relative standard deviation obtaining 1.1% and 3.0% for intra-day precision and inter-day precision, respectively. The detection limit was 0.021mgL -1 and the sample throughput for the entire process was 3.4h -1 . The proposed method was applied for the determination of CLB in human urine and milk substitute samples obtaining recoveries values within a range of 94.0-100.0%. Copyright © 2017 Elsevier B.V. All rights reserved.
Lu, Yang; Yao, Hui; Li, Chuang; Han, Juan; Tan, Zhenjiang; Yan, Yongsheng
2016-02-01
Polyoxyethylene lauryl ether (POELE10)-NaH2PO4 aqueous two-phase extraction system (ATPES) is coupled with HPLC to analyze chloramphenicol (CAP) in aquatic product. Response surface methodology (RSM) was adopted in the multi-factor experiment to determine the optimized conditions. The extraction efficiency of CAP (E%) is up to 99.42% under the optimal conditions, namely, the concentration of NaH2PO4, the concentration of POELE10, pH and temperature were 0.186 g · mL(-1), 0.033 g · mL(-1), 3.8 and 25 °C respectively. The optimal value of enrichment factor of CAP (F) was 22.56 when the concentration of NaH2PO4 was 0.192 g · mL(-1), the concentration of POELE10 was 0.024 g/ml, pH was 4.2 and temperature was 30 °C. The limit of detection (LOD) and limit of quantification (LOQ) of this method are 0.8 μg · kg(-1) and 1 μg · kg(-1), which meet the needs of determining trace or ultratrace CAP in food. The E% and F of this technique are much better than other extraction methods. Copyright © 2015 Elsevier Ltd. All rights reserved.
De Toffoli, Ana L; Fumes, Bruno H; Lanças, Fernando M
2018-02-22
On-line in-tube solid phase microextraction (in-tube SPME) coupled to high performance liquid chromatography and tandem mass spectrometry (HPLC-MS/MS) was successfully applied to the determination of selected triazines in water samples. The method based on the employment of a packed column containing graphene oxide (GO) supported on aminopropyl silica (Si) showed that the extraction phase has a high potential for triazines extraction aiming to its physical-chemical properties including ultrahigh specific surface area, good mechanical and thermal stability and high fracture strength. Injection volume and loading time were both investigated and optimized. The method validation using Si-GO to extract and concentrate the analytes showed satisfactory results, good sensitivity, good linearity (0.2-4.0 µg L -1 ) and low detection limits (1.1-2.9 ng L -1 ). The high extraction efficiency was determined with enrichment factors ranging from 1.2-2.9 for the lowest level, 1.3-4.9 intermediate level and 1.2-3.0 highest level (n = 3). Although the analytes were not detected in the real samples evaluated, the method has demonstrated to be efficient through its application in the analysis of spiked triazines in ground and mineral water samples.
Boisvert, Michel; Fayad, Paul B; Sauvé, Sébastien
2012-11-19
A new solid phase extraction (SPE) method coupled to a high throughput sample analysis technique was developed for the simultaneous determination of nine selected emerging contaminants in wastewater (atrazine, desethylatrazine, 17β-estradiol, ethynylestradiol, norethindrone, caffeine, carbamazepine, diclofenac and sulfamethoxazole). We specifically included pharmaceutical compounds from multiple therapeutic classes, as well as pesticides. Sample pre-concentration and clean-up was performed using a mixed-mode SPE cartridge (Strata ABW) having both cation and anion exchange properties, followed by analysis by laser diode thermal desorption atmospheric pressure chemical ionization coupled to tandem mass spectrometry (LDTD-APCI-MS/MS). The LDTD interface is a new high-throughput sample introduction method, which reduces total analysis time to less than 15s per sample as compared to minutes with traditional liquid-chromatography coupled to tandem mass spectrometry (LC-MS/MS). Several SPE parameters were evaluated in order to optimize recovery efficiencies when extracting analytes from wastewater, such as the nature of the stationary phase, the loading flow rate, the extraction pH, the volume and composition of the washing solution and the initial sample volume. The method was successfully applied to real wastewater samples from the primary sedimentation tank of a municipal wastewater treatment plant. Recoveries of target compounds from wastewater ranged from 78% to 106%, the limit of detection ranged from 30 to 122ng L(-1) while the limit of quantification ranged from 90 to 370ng L(-1). Calibration curves in the wastewater matrix showed good linearity (R(2)≥0.991) for all target analytes and the intraday and interday coefficient of variation was below 15%, reflecting a good precision. Copyright © 2012 Elsevier B.V. All rights reserved.
Beretta, Giangiacomo; Caneva, Enrico; Regazzoni, Luca; Bakhtyari, Nazanin Golbamaki; Maffei Facino, Roberto
2008-07-14
The aim of this work was to establish an analytical method for identifying the botanical origin of honey, as an alternative to conventional melissopalynological, organoleptic and instrumental methods (gas-chromatography coupled to mass spectrometry (GC-MS), high-performance liquid chromatography HPLC). The procedure is based on the (1)H nuclear magnetic resonance (NMR) profile coupled, when necessary, with electrospray ionisation-mass spectrometry (ESI-MS) and two-dimensional NMR analyses of solid-phase extraction (SPE)-purified honey samples, followed by chemometric analyses. Extracts of 44 commercial Italian honeys from 20 different botanical sources were analyzed. Honeydew, chestnut and linden honeys showed constant, specific, well-resolved resonances, suitable for use as markers of origin. Honeydew honey contained the typical resonances of an aliphatic component, very likely deriving from the plant phloem sap or excreted into it by sap-sucking aphids. Chestnut honey contained the typical signals of kynurenic acid and some structurally related metabolite. In linden honey the (1)H NMR profile gave strong signals attributable to the mono-terpene derivative cyclohexa-1,3-diene-1-carboxylic acid (CDCA) and to its 1-O-beta-gentiobiosyl ester (CDCA-GBE). These markers were not detectable in the other honeys, except for the less common nectar honey from rosa mosqueta. We compared and analyzed the data by multivariate techniques. Principal component analysis found different clusters of honeys based on the presence of these specific markers. The results, although obviously only preliminary, suggest that the (1)H NMR profile (with HPLC-MS analysis when necessary) can be used as a reference framework for identifying the botanical origin of honey.
Mariani, Maurizio Boccacci; Giannetti, Vanessa; Testani, Elena; Ceccarelli, Valentina
2013-01-01
The use of pesticides in agriculture has grown dramatically over the last decades. Environmental exposure of humans to agrochemicals is common and results in both acute and chronic health effects. In this study, direct immersion-solid phase microextraction (SPME) was coupled with electron capture detection for trace determination of 19 chlorinated pesticides in tomato samples, using a 100 pm polydimethylsiloxane fiber. The experimental parameters extraction time, extraction temperature, stirring, and salting out were evaluated and optimized. The LODs ranged from 0.5 to 8 microg/kg, and the LOQs from 5 to 30 microg/kg. A linear response was confirmed by correlation coefficients ranging from 0.97 to 0.9985. The developed method was tested by analyzing real samples purchased within the network of Italian distribution. The samples were found to be free from detectable residues of the studied pesticides. SPME has been shown to be a fast extraction technique that has several advantages such as solvent-free extraction, simplicity, and compatibility with the chromatographic analytical system.
Deng, Dong-Li; Zhang, Ji-You; Chen, Chen; Hou, Xiao-Ling; Su, Ying-Ying; Wu, Lan
2012-01-06
A novel capillary electrophoresis (CE) method coupled with monolithic molecular imprinted polymer (MIP) fiber based solid phase microextraction (SPME) was developed for selective and sensitive determination of ephedrine (E) and pseudoephedrine (PE). With in situ polymerization in a silica capillary mold and E as template, the MIP fibers could be produced in batch reproducibly and each fiber was available for 50 extraction cycles without significant decrease in extraction ability. Using the MIP fiber under optimized extraction conditions, CE detection limits of E and PE were greatly lowered from 0.20 to 0.00096 μg/mL and 0.12 to 0.0011 μg/mL, respectively. Analysis of urine and serum samples by the MIP-SPME-CE method was also performed, with results indicating that E and PE could be selectively extracted. The recoveries and relative standard deviations (RSDs) for sample analysis were found in the range of 91-104% and 3.8-9.1%, respectively. Copyright © 2011 Elsevier B.V. All rights reserved.
Luo, Xu-Biao; Chen, Bo; Yao, Shou-Zhuo
2006-01-01
An isocratic high-performance liquid chromatographic method coupled with electrospray mass spectrometry was developed to determine protopine, allocryptopine, sanguinarine and chelerythrine in fruits of Macleaya cordata. The sample was extracted with hydrochloric acid aqueous solution using microwave-assisted extraction method. The extracts were separated on a C8 reversed-phase HPLC column with acetonitrile:acetate buffer as mobile phase, and full elution of all analytes was realized isocratically within 10 min. The abundance of pseudomolecule ions was recorded using selected ion recording at m/z 354.4, 370.1, 332.5, 348.5 and 338.5 for protopine, allocryptopine, sanguinarine, chelerythrine and the internal standard, jatrorrhizine, respectively. Internal standard curves were used for the quantification of protopine, allocryptopine, sanguinarine and chelerythrine, which showed a linear range of 0.745-74.5, 0.610-61.0, 0.525-105 and 0.375-75 microg/mL, respectively, with correlation coefficients of 0.9995, 0.9992, 0.9993 and 0.9989, and limits of detection of 3.73, 3.05, 1.60 and 1.11 ng/mL, respectively.
Liu, Yaxi; Gao, Zongjun; Wu, Ri; Wang, Zhenhua; Chen, Xiangfeng; Chan, T-W Dominic
2017-01-06
In this work, magnetic porous carbon material derived from a bimetallic metal-organic framework was explored as an adsorbent for magnetic solid-phase extraction of organochlorine pesticides (OCPs). The synthesized porous carbon possessed a high specific surface area and magnetization saturation. The OCPs in the samples were quantified using gas chromatography coupled with a triple quadrupole mass spectrometer. The experimental parameters, including the desorption solvent and conditions, amount of adsorbent, extraction time, extraction temperature, and ionic strength of the solution, were optimized. Under optimal conditions, the developed method displayed good linearity (r>0.99) within the concentration range of 2-500ngL -1 . Low limits of detection (0.39-0.70ngL -1 , signal-to-noise ratio=3:1) and limits of quantification (1.45-2.0ngL -1 , signal-to-noise ratio=10:1) as well as good precision (relative standard deviation<10%) were also obtained. The developed method was applied in the analysis of OCPs in drinking and environmental water samples. Copyright © 2016 Elsevier B.V. All rights reserved.
Zhang, Hongmei; Wang, Yuzhi; Zhou, Yigang; Xu, Kaijia; Li, Na; Wen, Qian; Yang, Qin
2017-08-01
In this work, 16 kinds of novel deep eutectic solvents (DESs) composed of polyethylene glycol (PEG) and quaternary ammonium salts, were coupled with Aqueous Biphasic Systems (ABSs) to extract RNA. The phase forming ability of ABSs were comprehensively evaluated, involving the effects of various proportions of DESs' components, carbon chain length and anions species of quaternary ammonium salts, average molecular weights of PEG and inorganic salts nature. Then the systems were applied in RNA extraction, and the results revealed that the extraction efficiency values were distinctly enhanced by relatively lower PEG content in DESs, smaller PEG molecular weights, longer carbon chain of quaternary ammonium salts and more hydrophobic inorganic salts. Then the systems composed of [TBAB][PEG600] and Na 2 SO 4 were utilized in the influence factor experiments, proving that the electrostatic interaction was the dominant force for RNA extraction. Therefore, back-extraction efficiency values ranging between 85.19% and 90.78% were obtained by adjusting the ionic strength. Besides, the selective separation of RNA and tryptophane (Trp) was successfully accomplished. It was found that 86.19% RNA was distributed in the bottom phase, while 72.02% Trp was enriched in the top phase in the novel ABSs. Finally, dynamic light scattering (DLS) and transmission electron microscope (TEM) were used to further investigate the extraction mechanism. The proposed method reveals the outstanding feasibility of the newly developed ABSs formed by PEG-based DESs and inorganic salts for the green extraction of RNA. Copyright © 2017 Elsevier B.V. All rights reserved.
Cloud point extraction of Δ9-tetrahydrocannabinol from cannabis resin.
Ameur, S; Haddou, B; Derriche, Z; Canselier, J P; Gourdon, C
2013-04-01
A cloud point extraction coupled with high performance liquid chromatography (HPLC/UV) method was developed for the determination of Δ(9)-tetrahydrocannabinol (THC) in micellar phase. The nonionic surfactant "Dowfax 20B102" was used to extract and pre-concentrate THC from cannabis resin, prior to its determination with a HPLC-UV system (diode array detector) with isocratic elution. The parameters and variables affecting the extraction were investigated. Under optimum conditions (1 wt.% Dowfax 20B102, 1 wt.% Na2SO4, T = 318 K, t = 30 min), this method yielded a quite satisfactory recovery rate (~81 %). The limit of detection was 0.04 μg mL(-1), and the relative standard deviation was less than 2 %. Compared with conventional solid-liquid extraction, this new method avoids the use of volatile organic solvents, therefore is environmentally safer.
Cai, Ying; Yan, Zhihong; Wang, Lijia; NguyenVan, Manh; Cai, Qingyun
2016-01-15
A magnetic solid phase extraction (MSPE) protocol combining a static headspace gas chromatography coupled to mass spectrometry (HS-GC-MS) method has been developed for extraction, and determination of 16 polycyclic aromatic hydrocarbons (PAHs) in drinking water samples. Magnetic nanoparticles (MNPs) were coated with 3-aminopropyltriethoxysilane and modified by cholesterol chloroformate. Transmission electron microscope, vibrating sample magnetometer, Fourier transform infrared spectrometry and X-ray photoelectron spectroscopy were used to characterize the cholesterol-functionalized sorbents, and the main parameters affecting the extraction as well as HS sampling, such as sorbent amount, extraction time, oven temperature and equilibration time have been investigated and established. Combination with HS sampling, the MSPE procedure was simple, fast and environmentally friendly, without need of any organic solvent. Method validation proved the feasibility of the developed sorbents for the quantitation of the investigated analytes at trace levels obtaining the limit of detection (S/N=3) ranging from 0.20 to 7.8 ng/L. Good values for intra and inter-day precision were obtained (RSDs ≤ 9.9%). The proposed method was successfully applied to drinking water samples. Copyright © 2015 Elsevier B.V. All rights reserved.
Feng, Juanjuan; Sun, Min; Bu, Yanan; Luo, Chuannan
2015-01-01
A novel nanostructured copper-based solid-phase microextraction fiber was developed and applied for determining the two most common types of phthalate environmental estrogens (dibutyl phthalate and diethylhexyl phthalate) in aqueous samples, coupled to gas chromatography with flame ionization detection. The copper film was coated onto a stainless-steel wire via an electroless plating process, which involved a surface activation process to improve the surface properties of the fiber. Several parameters affecting extraction efficiency such as extraction time, extraction temperature, ionic strength, desorption temperature, and desorption time were optimized by a factor-by-factor procedure to obtain the highest extraction efficiency. The as-established method showed wide linear ranges (0.05-250 μg/L). Precision of single fiber repeatability was <7.0%, and fiber-to-fiber repeatability was <10%. Limits of detection were 0.01 μg/L. The proposed method exhibited better or comparable extraction performance compared with commercial and other lab-made fibers, and excellent thermal stability and durability. The proposed method was applied successfully for the determination of model analytes in plastic soaking water. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Wu, Xiaoling; Yang, Miyi; Zeng, Haozhe; Xi, Xuefei; Zhang, Sanbing; Lu, Runhua; Gao, Haixiang; Zhou, Wenfeng
2016-11-01
In this study, a simple effervescence-assisted dispersive solid-phase extraction method was developed to detect fungicides in honey and juice. Most significantly, an innovative ionic-liquid-modified magnetic β-cyclodextrin/attapulgite sorbent was used because its large specific surface area enhanced the extraction capacity and also led to facile separation. A one-factor-at-a-time approach and orthogonal design were employed to optimize the experimental parameters. Under the optimized conditions, the entire extraction procedure was completed within 3 min. In addition, the calibration curves exhibited good linearity, and high enrichment factors were achieved for pure water and honey samples. For the honey samples, the extraction efficiencies for the target fungicides ranged from 77.0 to 94.3% with relative standard deviations of 2.3-5.44%. The detection and quantitation limits were in the ranges of 0.07-0.38 and 0.23-1.27 μg/L, respectively. Finally, the developed technique was successfully applied to real samples, and satisfactory results were achieved. This analytical technique is cost-effective, environmentally friendly, and time-saving. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Khajeh, Mostafa; Sarafraz-Yazdi, Ali; Natavan, Zahra Bameri
2016-03-01
The aim of this research was to develop a low price and environmentally friendly adsorbent with abundant of source to remove methylene blue (MB) from water samples. Sawdust solid-phase extraction coupled with high-performance liquid chromatography was used for the extraction and determination of MB. In this study, an experimental data-based artificial neural network model is constructed to describe the performance of sawdust solid-phase extraction method for various operating conditions. The pH, time, amount of sawdust, and temperature were the input variables, while the percentage of extraction of MB was the output. The optimum operating condition was then determined by genetic algorithm method. The optimized conditions were obtained as follows: 11.5, 22.0 min, 0.3 g, and 26.0°C for pH of the solution, extraction time, amount of adsorbent, and temperature, respectively. Under these optimum conditions, the detection limit and relative standard deviation were 0.067 μg L(-1) and <2.4%, respectively. The Langmuir and Freundlich adsorption models were applied to describe the isotherm constant and for the removal and determination of MB from water samples. © The Author(s) 2013.
Brede, C; Skjevrak, I; Herikstad, H; Anensen, E; Austvoll, R; Hemmingsen, T
2002-05-01
A straightforward method was established for the determination of migration contaminants in olive oil with a special focus on the two can-coating migration compounds bisphenol A diglycidyl ether (BADGE) and bisphenol F diglycidyl ether (BFDGE). The preferred sample preparation was a single liquid-liquid extraction of compounds from the oil into 20% (v/v) methanol in acetonitrile, followed by clean-up with solid-phase extraction on aminopropyl bonded to silica. This purification procedure selectively removed all free fatty acids from the extracts without removing phenolic compounds of interest. The solid-phase extraction columns were used many times by implementing a procedure of washing out the strongly retained fatty acids with 2% acetic acid in methanol. Gas chromatography coupled with full scan (m/z 33-700) electron ionization mass spectrometry was used for the determination of several model compounds in olive oil samples. BADGE and BFDGE could be determined in the 0.05-2 mg kg(-1) range in oil samples with a relative SD of <6% (six replicates). The method was used in an enforcement campaign for the Norwegian Food Control Authority to analyse vegetable oil samples from canned fish-in-oil.
Akbarzade, Samaneh; Chamsaz, Mahmoud; Rounaghi, Gholam Hossein; Ghorbani, Mahdi
2018-01-01
A selective and sensitive magnetic dispersive solid-phase microextraction (MDSPME) coupled with gas chromatography-mass spectrometry was developed for extraction and determination of organophosphorus pesticides (Sevin, Fenitrothion, Malathion, Parathion, and Diazinon) in fruit juice and real water samples. Zero valent Fe-reduced graphene oxide quantum dots (rGOQDs@ Fe) as a new and effective sorbent were prepared and applied for extraction of organophosphorus pesticides using MDSPME method. In order to study the performance of this new sorbent, the ability of rGOQDs@ Fe was compared with graphene oxide and magnetic graphene oxide nanocomposite by recovery experiments of the organophosphorus pesticides. Several affecting parameters in the microextraction procedure, including pH of donor phase, donor phase volume, stirring rate, extraction time, and desorption conditions such as the type and volume of solvents and desorption time were thoroughly investigated and optimized. Under the optimal conditions, the method showed a wide linear dynamic range with R-square between 0.9959 and 0.9991. The limit of detections, the intraday and interday relative standard deviations (n = 5) were less than 0.07 ngmL -1 , 4.7, and 8.6%, respectively. The method was successfully applied for extraction and determination of organophosphorus pesticides in real water samples (well, river and tap water) and fruit juice samples (apple and grape juice). The obtained relative recoveries were in the range of 82.9%-113.2% with RSD percentages of less than 5.8% for all the real samples.
Taghvimi, Arezou; Hamishehkar, Hamed; Ebrahimi, Mahmoud
2016-01-15
This paper reports on a method based on magnetic solid phase extraction (MSPE) for the determination of pseudoephedrine. Magnetic nanographene oxide (MNGO) was applied as a new adsorbent for the extraction of pseudoephedrine from urine samples. Synthesis of MNGO was characterized by Fourier transform infrared (FT-IR) spectroscopy, scanning electron microscopy (SEM), powder X-ray diffraction (XRD), and vibrating sample magnetometer (VSM). The main factors influencing extraction efficiency, including the amounts of sample volume, amount of adsorbent, type and amount of extraction organic solvent, time of extraction and desorption, pH, ionic strength of extraction medium, and agitation rate, were investigated and optimized. Under optimized extraction conditions, a good linearity was observed in the range of 100-2000ng/mL with a correlation coefficient of 0.9908 (r(2)). Limit of detection (LOD) and limit of quantification (LOQ) were 25 and 82.7ng/mL, respectively. Inter-day and intra-day precision and accuracy were 6.01 and 0.34 (%), and 8.70 and 0.29 (%), respectively. The method was applied for the determination of pseudoephedrine in urine samples of volunteers receiving pseudoephedrine with the recovery of 96.42. It was concluded that the proposed method can be applied in diagnostic clinics. Copyright © 2015 Elsevier B.V. All rights reserved.
Phase-lock-loop application for fiber optic receiver
NASA Astrophysics Data System (ADS)
Ruggles, Stephen L.; Wills, Robert W.
1991-02-01
Phase-locked loop circuits are frequently employed in communication systems. In recent years, digital phase-locked loop circuits were utilized in optical communications systems. In an optical transceiver system, the digital phase-locked loop circuit is connected to the output of the receiver to extract a clock signal from the received coded data (NRZ, Bi-Phase, or Manchester). The clock signal is then used to reconstruct or recover the original data from the coded data. A theoretical approach to the design of a digital phase-locked loop circuit operation at 1 and 50 MHz is described. Hardware implementation of a breadboard design to function at 1 MHz and a printed-circuit board designed to function at 50 MHz were assembled using emitter coupled logic (ECL) to verify experimentally the theoretical design.
Phase-lock-loop application for fiber optic receiver
NASA Technical Reports Server (NTRS)
Ruggles, Stephen L.; Wills, Robert W.
1991-01-01
Phase-locked loop circuits are frequently employed in communication systems. In recent years, digital phase-locked loop circuits were utilized in optical communications systems. In an optical transceiver system, the digital phase-locked loop circuit is connected to the output of the receiver to extract a clock signal from the received coded data (NRZ, Bi-Phase, or Manchester). The clock signal is then used to reconstruct or recover the original data from the coded data. A theoretical approach to the design of a digital phase-locked loop circuit operation at 1 and 50 MHz is described. Hardware implementation of a breadboard design to function at 1 MHz and a printed-circuit board designed to function at 50 MHz were assembled using emitter coupled logic (ECL) to verify experimentally the theoretical design.
Du, Kunze; Li, Jin; Tian, Fei; Chang, Yan-Xu
2018-02-20
A simple nonionic detergent - based vortex- synchronized matrix solid-phase dispersion (ND-VSMSPD) method was developed to extract bioactive compounds in Forsythiae Fructus coupled with ultra high-performance liquid chromatography (UHPLC). Nonionic detergent Triton 114 was firstly used as a green elution reagent in vortex- synchronized MSPD procedure. The optimum parameters were investigated to attain the best results, including Florisil as sorbent, 2mL 10% (v/v) nonionic detergent Triton X-114 as the elution reagent, 1:1 of sample/sorbent ratio, grinding for 3min, and whirling for 2min. The recoveries of the six compounds in Forsythiae Fructus were in the range of 95-104% (RSD <4.6%) and the method displayed a good linearity within the range of 0.08-20μgmL -1 for caffeic acid, 0.6-150μgmL -1 for forsythoside A, 0.4-100μgmL -1 phillyrin, 0.2-50μgmL -1 for quercetin, isorhamnetin and arctigenin (r≥0.999). It was proved that the extraction yields of almost all compounds attained by the established vortex- synchronized MSPD, which required lower sample, reagent and time, were higher than the normal MSPD and the traditional ultrasonic-assisted extraction. Consequently, this developed vortex- synchronized MSPD coupled with simple UHPLC method could be efficiently applies to extract and analyze the target compounds in real Forsythiae Fructus samples. Copyright © 2017 Elsevier B.V. All rights reserved.
Ma, Jiping; Wu, Gege; Li, Shuang; Tan, Weiqiang; Wang, Xiaoyan; Li, Jinhua; Chen, Lingxin
2018-06-08
A simple method of magnetic solid-phase extraction (MSPE) coupled to high performance liquid chromatography (HPLC) was developed for the simultaneous extraction and determination of four kinds of heterocyclic pesticides (carbendazim, triadimefon, chlorfenapyr and fenpyroximate) in environmental water samples. Magnetic metal-organic frameworks (MOFs) of type MOF-5 were prepared and used as adsorbents of MSPE. Several main parameters influencing MSPE efficiency were investigated, including amount of magnetic MOF-5, sample solution pH, extraction time, salt concentration, type and volume of desorption solvents and desorption time. Under optimal conditions, the MSPE-HPLC method presented fast simple separation and analysis, and excellent linearity in the range of 0.3-500.0 μg/L for carbendazim and triadimefon, and 0.1-500.0 μg/L for chlorfenapyr and fenpyroximate, with correlation coefficients (r) higher than 0.9992. High sensitivity with limits of detection and quantification ranging from 0.04-0.11 μg/L and 0.13-0.35 μg/L, respectively, were achieved, as well as good precision with relative standard deviations of 2.98-7.11% (intra-day) and 3.31-7.12% (inter-day). Furthermore, the method was successfully applied to reservoir and Yellow River water samples, and satisfactory recoveries at three spiked concentration levels were between 80.20% and 108.33%.The magnetic MOF-5 composites based MSPE followed by HPLC proved promising for convenient and efficient determination of heterocyclic pesticides in environmental water samples. Copyright © 2018 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Errayess, Sophia Ait; Lahcen, Abdellatif Ait; Idrissi, Laila; Marcoaldi, Caterina; Chiavarini, Salvatore; Amine, Aziz
2017-06-01
The authors have developed a sensitive spectrophotometric method for determination of sulfonamide derivatives such as sulfanilamide (SAA), sulfadiazine (SDZ), sulfacetamide (SCT) sulfamethoxazole (SMX), sulfamerazine (SMR), sulfadimethoxine (SDX), sulfamethiazole (SMT) and Sulfathiazole (STZ). This method is based on the Bratton-Marshall reaction, which involves the diazotization of sulfonamides with sodium nitrite under acidic conditions, followed by coupling with N-(1-naphtyl) ethylenediamine dihydrochloride (NED) to form a pink colored compound. Therefore, the Bratton-Marshall method was modified by optimizing the reaction conditions, which allows us to determine a low concentration range of sulfonamides compared to the reported methods. The limits of detection and quantification obtained were 0.019-0.05 and 0.06-0.16 μg mL- 1, respectively. In comparison with other reported methods using different coupling agents, the proposed method was found to be the most simple and sensitive for sulfonamides determination. In this paper, the modified method was successfully employed for the determination of sulfonamides in drinking water, seawater and pharmaceutical and veterinary formulations. The purpose of this work is to optimize and develop a simple method for extraction and concentration of sulfonamides present as residues in seawater and their quantification with the recommended spectrophotometric method. Solid phase extraction (SPE) of sulfonamides from seawater samples was evaluated using Oasis HLB cartridges (3 mL, 540 mg). The recovery efficiency was investigated in the sulfonamides concentration range comprised between 0.19 and 126 ng mL- 1. The ease of use of this extraction method makes it very useful for routine laboratory work.
Wang, Yu-Qing; Tang, Xu; Li, Jia-Fu; Wu, Yun-Long; Sun, Yu-Ying; Fang, Mei-Juan; Wu, Zhen; Wang, Xiu-Min; Qiu, Ying-Kun
2017-10-13
A novel on-line comprehensive two-dimensional liquid chromatography (2D-LC) method by coupling mixed-mode gel liquid chromatography (MMG-LC) with reversed phase liquid chromatography (RPLC) was developed. A mixture of 17 reference compounds was used to study the separation mechanism. A crude water extract of Flos Carthami was applied to evaluate the performance of the novel 2D-LC system. In the first dimension, the extract was eluted with a gradient of water/methanol over a cross-linked dextran gel Sephadex LH-20 column. Meanwhile, the advantages of size exclusion, reversed phase partition and adsorption separation mechanism were exploited before further on-line reversed phase purification on the second dimension. This novel on-line mixed-mode Sephadex LH-20×RPLC method provided higher peak resolution, sample processing ability (2.5mg) and better orthogonality (72.9%) versus RPLC×RPLC and hydrophilic interaction liquid chromatography (HILIC)×RPLC. To the best of our knowledge, this is the first report of a mixed-mode Sephadex LH-20×RPLC separation method with successful applications in on-line mode, which might be beneficial for harvesting targets from complicated medicinal plants. Copyright © 2017 Elsevier B.V. All rights reserved.
Saito, Samuel Takashi; Trentin, Danielle da Silva; Macedo, Alexandre José; Pungartnik, Cristina; Gosmann, Grace; Silveira, Jaqueline de Deos; Guecheva, Temenouga Nikolova; Henriques, João Antonio Pêgas; Brendel, Martin
2012-01-01
Plant extracts have a long history to be used in folk medicine. Cassia alata extracts are known to exert antibacterial activity but details on compounds and mechanism of action remain poorly explored. We purified and concentrated the aqueous leaf extract of C. alata by reverse phase-solid phase extraction and screened the resulting CaRP extract for antimicrobial activity. CaRP extract exhibited antimicrobial activity for Pseudomonas aeruginosa, Staphylococcus epidermidis, S. aureus, and Bacillus subtilis. CaRP also inhibited biofilm formation of S. epidermidis and P. aeruginosa. Several bacterial growth-inhibiting compounds were detected when CaRP extract was fractionated by TLC chromatography coupled to bioautography agar overlay technique. HPLC chromatography of CaRP extract yielded 20 subfractions that were tested by bioautography for antimicrobial activity against S. aureus and S. epidermidis. Five bioactive fractions were detected and chemically characterized, using high-resolution mass spectrometry (qTOF-MS/MS). Six compounds from four fractions could be characterized as kaempferol, kaempferol-O-diglucoside, kaempferol-O-glucoside, quercetin-O-glucoside, rhein, and danthron. In the Salmonella/microsome assay CaRP showed weak mutagenicity (MI < 3) only in strain TA98, pointing to a frameshift mutation activity. These results indicate that C. alata leaf extract contains a minimum of 7 compounds with antimicrobial activity and that these together or as single substance are active in preventing formation of bacterial biofilm, indicating potential for therapeutic applications. PMID:22548121
Saito, Samuel Takashi; Trentin, Danielle da Silva; Macedo, Alexandre José; Pungartnik, Cristina; Gosmann, Grace; Silveira, Jaqueline de Deos; Guecheva, Temenouga Nikolova; Henriques, João Antonio Pêgas; Brendel, Martin
2012-01-01
Plant extracts have a long history to be used in folk medicine. Cassia alata extracts are known to exert antibacterial activity but details on compounds and mechanism of action remain poorly explored. We purified and concentrated the aqueous leaf extract of C. alata by reverse phase-solid phase extraction and screened the resulting CaRP extract for antimicrobial activity. CaRP extract exhibited antimicrobial activity for Pseudomonas aeruginosa, Staphylococcus epidermidis, S. aureus, and Bacillus subtilis. CaRP also inhibited biofilm formation of S. epidermidis and P. aeruginosa. Several bacterial growth-inhibiting compounds were detected when CaRP extract was fractionated by TLC chromatography coupled to bioautography agar overlay technique. HPLC chromatography of CaRP extract yielded 20 subfractions that were tested by bioautography for antimicrobial activity against S. aureus and S. epidermidis. Five bioactive fractions were detected and chemically characterized, using high-resolution mass spectrometry (qTOF-MS/MS). Six compounds from four fractions could be characterized as kaempferol, kaempferol-O-diglucoside, kaempferol-O-glucoside, quercetin-O-glucoside, rhein, and danthron. In the Salmonella/microsome assay CaRP showed weak mutagenicity (MI < 3) only in strain TA98, pointing to a frameshift mutation activity. These results indicate that C. alata leaf extract contains a minimum of 7 compounds with antimicrobial activity and that these together or as single substance are active in preventing formation of bacterial biofilm, indicating potential for therapeutic applications.
Ponce-Robles, Laura; Rivas, Gracia; Esteban, Belen; Oller, Isabel; Malato, Sixto; Agüera, Ana
2017-10-01
An analytical method was developed and validated for the determination of ten pesticides in sewage sludge coming from an agro-food industry. The method was based on the application of Quick, Easy, Cheap, Effective, Rugged, and Safe (QuEChERS) extraction for solid sewage sludge and SPE extraction for sludge aqueous phase, followed by liquid chromatography (LC) coupled to hybrid quadrupole/linear ion trap mass spectrometry (QqLIT-MS). The QuEChERS method was reported 14 years ago and nowadays is mainly applied to the analysis of pesticides in food. More recent applications have been reported in other matrices as sewage sludge, but the complexity of the matrix makes necessary the optimization of the cleanup step to improve the efficiency of the analysis. With this aim, several dispersive solid-phase extraction cleanup sorbents were tested, choosing C18 + PSA as a d-SPE sorbent. The proposed method was satisfactorily validated for most compounds investigated, showing recoveries higher than 80% in most cases, with the only exception of prochloraz (71%) at low concentration level. Limits of quantification were lower than 40 ng l -1 in the aqueous phase and below 40 ng g -1 in the solid phase for the majority of the analytes. The method was applied to solid sludge and the sludge aqueous phase coming from an agro-food industry which processes fruits and vegetables. Graphical abstract Application of LC/MS/MS advanced analytical techniques for determination of pesticides contained in sewage sludge.
Louveau, B; Fernandez, C; Zahr, N; Sauvageon-Martre, H; Maslanka, P; Faure, P; Mourah, S; Goldwirt, L
2016-12-01
A precise and accurate high-performance liquid chromatography (HPLC) quantification method of rifampicin in human plasma was developed and validated using ultraviolet detection after an automatized solid-phase extraction. The method was validated with respect to selectivity, extraction recovery, linearity, intra- and inter-day precision, accuracy, lower limit of quantification and stability. Chromatographic separation was performed on a Chromolith RP 8 column using a mixture of 0.05 m acetate buffer pH 5.7-acetonitrile (35:65, v/v) as mobile phase. The compounds were detected at a wavelength of 335 nm with a lower limit of quantification of 0.05 mg/L in human plasma. Retention times for rifampicin and 6,7-dimethyl-2,3-di(2-pyridyl) quinoxaline used as internal standard were respectively 3.77 and 4.81 min. This robust and exact method was successfully applied in routine for therapeutic drug monitoring in patients treated with rifampicin. Copyright © 2016 John Wiley & Sons, Ltd.
Chen, Ping-Hung; Chen, Shun-Niang; Tseng, Sheng-Hao; Deng, Ming-Jay; Lin, Yang-Wei; Sun, Yuh-Chang
2016-01-01
This paper describes a fabrication protocol for a dipole-assisted solid phase extraction (SPE) microchip available for trace metal analysis in water samples. A brief overview of the evolution of chip-based SPE techniques is provided. This is followed by an introduction to specific polymeric materials and their role in SPE. To develop an innovative dipole-assisted SPE technique, a chlorine (Cl)-containing SPE functionality was implanted into a poly(methyl methacrylate) (PMMA) microchip. Herein, diverse analytical techniques including contact angle analysis, Raman spectroscopic analysis, and laser ablation-inductively coupled plasma-mass spectrometry (LA-ICP-MS) analysis were employed to validate the utility of the implantation protocol of the C-Cl moieties on the PMMA. The analytical results of the X-ray absorption near-edge structure (XANES) analysis also demonstrated the feasibility of the Cl-containing PMMA used as an extraction medium by virtue of the dipole-ion interactions between the highly electronegative C-Cl moieties and the positively charged metal ions. PMID:27584954
Aydin, Funda Armagan; Soylak, Mustafa
2010-01-15
A simple and effective method is presented for the separation and preconcentration of Th(IV), Ti(IV), Fe(III), Pb(II) and Cr(III) by solid phase extraction on 2-nitroso-1-naphthol impregnated MCI GEL CHP20P resin prior to their inductively coupled plasma-mass spectrometric determinations. The influence of analytical parameters including pH of the aqueous solution, flow rates of sample and eluent solutions and sample volume on the quantitative recoveries of analyte ions was investigated. Matrix effects caused by the presence of alkali, earth alkali and some metal ions in the analyzed solutions were investigated. The presented solid phase extraction method was applied to BCR-144R Sewage Sludge (domestic origin), BCR-141R Calcareous Loam Soil, NIST 1568a Rice Flour and NIST 1577b Bovine Liver certified reference materials (CRMs) for the determination of analyte ions and the results were in good agreement with the certified values. The separation procedure presented was also applied to the various natural water samples collected from Turkey with satisfactory results.
Analytical strategies for organic food packaging contaminants.
Sanchis, Yovana; Yusà, Vicent; Coscollà, Clara
2017-03-24
In this review, we present current approaches in the analysis of food-packaging contaminants. Gas and liquid chromatography coupled to mass spectrometry detection have been widely used in the analysis of some relevant families of these compounds such as primary aromatic amines, bisphenol A, bisphenol A diglycidyl ether and related compounds, UV-ink photoinitiators, perfluorinated compounds, phthalates and non-intentionally added substances. Main applications for sample treatment and different types of food-contact material migration studies have been also discussed. Pressurized Liquid Extraction, Solid-Phase Microextraction, Focused Ultrasound Solid-Liquid Extraction and Quechers have been mainly used in the extraction of food contact material (FCM) contaminants, due to the trend of minimising solvent consumption, automatization of sample preparation and integration of extraction and clean-up steps. Recent advances in analytical methodologies have allowed unequivocal identification and confirmation of these contaminants using Liquid Chromatography coupled to High Resolution Mass Spectrometry (LC-HRMS) through mass accuracy and isotopic pattern applying. LC-HRMS has been used in the target analysis of primary aromatic amines in different plastic materials, but few studies have been carried out applying this technique in post-target and non-target analysis of FCM contaminants. Copyright © 2017 Elsevier B.V. All rights reserved.
Hogendoorn, E A; Westhuis, K; Dijkman, E; Heusinkveld, H A; den Boer, A C; Evers, E A; Baumann, R A
1999-10-08
The coupled-column (LC-LC) configuration consisting of a 3 microm C18 column (50 x 4.6 mm I.D.) as the first column and a 5 microm C18 semi-permeable-surface (SPS) column (150 x 4.6 mm I.D.) as the second column appeared to be successful for the screening of acidic pesticides in surface water samples. In comparison to LC-LC employing two C18 columns, the combination of C18/SPS-C18 significantly decreased the baseline deviation caused by the hump of the co-extracted humic substances when using UV detection (217 nm). The developed LC-LC procedure allowed the simultaneous determination of the target analytes bentazone and bromoxynil in uncleaned extracts of surface water samples to a level of 0.05 microg/l in less than 15 min. In combination with a simple solid-phase extraction step (200 ml of water on a 500 mg C18-bonded silica) the analytical procedure provides a high sample throughput. During a period of about five months more than 200 ditch-water samples originating from agricultural locations were analyzed with the developed procedure. Validation of the method was performed by randomly analyzing recoveries of water samples spiked at levels of 0.1 microg/l (n=10), 0.5 microg/l (n=7) and 2.5 microg/l (n=4). Weighted regression of the recovery data showed that the method provides overall recoveries of 95 and 100% for bentazone and bromoxynil, respectively, with corresponding intra-laboratory reproducibilities of 10 and 11%, respectively. Confirmation of the analytes in part of the samples extracts was carried out with GC-negative ion chemical ionization MS involving a derivatization step with bis(trifluoromethyl)benzyl bromide. No false negatives or positives were observed.
Lou, Chaoyan; Wu, Can; Zhang, Kai; Guo, Dandan; Jiang, Lei; Lu, Yang; Zhu, Yan
2018-05-18
Allergenic disperse dyes are a group of environmental contaminants, which are toxic and mutagenic to human beings. In this work, a method of dispersive solid-phase extraction (d-SPE) using graphene-coated polystyrene-divinylbenzene (G@PS-DVB) microspheres coupled with supercritical fluid chromatography (SFC) was proposed for the rapid determination of 10 allergenic disperse dyes in industrial wastewater samples. G@PS-DVB microspheres were synthesized by coating graphene (G) sheets onto polystyrene-divinylbenzene (PS-DVB) polymers. Such novel sorbents were employed in d-SPE for the purification and concentration of allergenic disperse dyes in wastewater samples prior to the determination by SFC with UV detection. To achieve the maximum extraction efficiency for the target dyes, several parameters influencing d-SPE process such as sorbent dosage, extraction time, desorption conditions were investigated. SFC conditions including stationary phase, modifier composition and percentage, column temperature, backpressure and flow rate were optimized to well separate the allergenic disperse dyes. Under the optimum conditions, satisfactory linear relationship (R ≥ 0.9989) was observed with the concentration of dyes ranging from 0.02 to 10.0 μg/mL. The limits of detection (LOD, S/N = 3) for the ten dyes were in the range of 1.1-15.6 ng/mL. Recoveries for the spiked samples were between 89.1% and 99.7% with relative standard deviations (RSD) lower than 10.5% in all cases. The proposed method is time-saving, green, precise and repeatable for the analysis of the target dyes. Furthermore, the application of G@PS-DVB based d-SPE process can be potentially expanded to isolate and concentrate other aromatic compounds in various matrices and supercritical fluid chromatography methodology featuring rapidity, accuracy and green will be an ideal candidate for the analysis of these compounds. Copyright © 2018 Elsevier B.V. All rights reserved.
Xie, Li; Chen, Liqin; Gu, Pan; Wei, Lanlan; Kang, Xuejun
2018-03-01
The extraction and analysis of catecholamine neurotransmitters in biological fluids is of great importance in assessing nervous system function and related diseases, but their precise measurement is still a challenge. Many protocols have been described for neurotransmitter measurement by a variety of instruments, including high-pressure liquid chromatography (HPLC). However, there are shortcomings, such as complicated operation or hard-to-detect multiple targets, which cannot be avoided, and presently, the dominant analysis technique is still HPLC coupled with sensitive electrochemical or fluorimetric detection, due to its high sensitivity and good selectivity. Here, a detailed protocol is described for the pretreatment and detection of catecholamines with high pressure liquid chromatography with electrochemical detection (HPLC-ECD) in real urine samples of infants, using electrospun composite nanofibers composed of polymeric crown ether with polystyrene as adsorbent, also known as the packed-fiber solid phase extraction (PFSPE) method. We show how urine samples can be easily precleaned by a nanofiber-packed solid phase column, and how the analytes in the sample can be rapidly enriched, desorbed, and detected on an ECD system. PFSPE greatly simplifies the pretreatment procedures for biological samples, allowing for decreased time, expense, and reduction of the loss of targets. Overall, this work illustrates a simple and convenient protocol for solid-phase extraction coupled to an HPLC-ECD system for simultaneous determination of three monoamine neurotransmitters (norepinephrine (NE), epinephrine (E), dopamine (DA)) and two of their metabolites (3-methoxy-4-hydroxyphenylglycol (MHPG) and 3,4-dihydroxy-phenylacetic acid (DOPAC)) in infants' urine. The established protocol was applied to assess the differences of urinary catecholamines and their metabolites between high-risk infants with perinatal brain damage and healthy controls. Comparative analysis revealed a significant difference in urinary MHPG between the two groups, indicating that the catecholamine metabolites may be an important candidate marker for early diagnosis of cases at risk for brain damage in infants.
Liu, Yue; Hu, Jia; Li, Yan; Li, Xiao-Shuang; Wang, Zhong-Liang
2016-10-01
A novel method with high sensitivity for the rapid determination of chrysin, apigenin and luteolin in environment water samples was developed by double-pumps controlled on-line solid-phase extraction (SPE) coupled with high-performance liquid chromatography (HPLC). In the developed technique, metal organic framework MIL-101 was synthesized and applied as a sorbent for SPE. The as-synthesized MIL-101 was characterized by scanning electron microscope, X-ray diffraction spectrometry, thermal gravimetric analysis and micropore physisorption analysis. The MIL-101 behaved as a fast kinetics in the adsorption of chrysin, apigenin and luteolin. On-line SPE of chrysin, apigenin and luteolin was processed by loading a sample solution at a flow rate of 1.0 mL/min for 10 min. The extracted analytes were subsequently eluted into a ZORBAX Bonus-RP analytical column (25 cm long × 4.6 mm i.d.) for HPLC separation under isocratic condition with a mobile phase (MeOH: ACN: 0.02 M H 3 PO 4 = 35:35:30) at a flow rate of 1.0 mL/min. Experimental conditions, including ionic strength, sample pH, sample loading rates, sample loading time and desorption analytes time, were further optimized to obtain efficient preconcentration and high-precision determination of the analytes mentioned above. The method achieved the merits of simplicity, rapidity, sensitivity, wide linear range and high sample throughput. The possible mechanism for the adsorption of flavonoids on MIL-101 was proposed. The developed method has been applied to determine trace chrysin, apigenin and luteolin in a variety of environmental water samples. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Souza, Lais A; Rosende, María; Korn, Maria Graças A; Miró, Manuel
2018-10-05
An automatic flow-through dynamic extraction method is proposed for the first time for in vitro exploration, with high temporal resolution, of the transit of the chyme from the gastric to the duodenal compartment using the Versantvoort's fed-state physiologically relevant extraction test. The flow manifold was coupled on-line to an inductively coupled plasma optical emission spectrometer (ICP OES) for real-time elucidation of the bioaccessible elemental fraction of micronutrients (viz., Cu, Fe and Mn) in food commodities across the gastrointestinal tract. The simulated intestinal and bile biofluid (added to the gastric phase) was successively pumped at 1.0 mL min -1 through a large-bore column (maintained at 37.0 ± 2.0 °C) initially loaded with a weighed amount of linseed (250 mg) using a PVDF filter membrane (5.0 μm pore size) for retaining of the solid sample and in-line filtration of the extracts. The lack of bias (trueness) of the on-line gastrointestinal extraction method coupled to ICP OES was confirmed using mass balance validation following microwave assisted digestion of the residual (non-bioaccessible) elemental fraction. Mass balance validation yielded absolute recoveries spanning from 79 to 121% for the overall analytes and samples. On-line dynamic extraction was critically appraised against batch counterparts for both gastric and gastrointestinal compartments. Due to the lack of consensus in the literature regarding the agitation method for batch oral bioaccessibility testing, several extraction approaches (viz., magnetic stirring, end-over-end rotation and orbital shaking) were evaluated. Improved gastric extractability of Fe along with bioaccessible data comparable to the dynamic counterpart based on the continuous displacement of the extraction equilibrium was obtained with batchwise magnetic stirring, which is deemed most appropriate for ascertaining worst-case/maximum bioaccessibility scenarios. Copyright © 2018 Elsevier B.V. All rights reserved.
Electron—phonon Coupling and the Superconducting Phase Diagram of the LaAlO3—SrTiO3 Interface
Boschker, Hans; Richter, Christoph; Fillis-Tsirakis, Evangelos; Schneider, Christof W.; Mannhart, Jochen
2015-01-01
The superconductor at the LaAlO3—SrTiO3 interface provides a model system for the study of two-dimensional superconductivity in the dilute carrier density limit. Here we experimentally address the pairing mechanism in this superconductor. We extract the electron—phonon spectral function from tunneling spectra and conclude, without ruling out contributions of further pairing channels, that electron—phonon mediated pairing is strong enough to account for the superconducting critical temperatures. Furthermore, we discuss the electron—phonon coupling in relation to the superconducting phase diagram. The electron—phonon spectral function is independent of the carrier density, except for a small part of the phase diagram in the underdoped region. The tunneling measurements reveal that the increase of the chemical potential with increasing carrier density levels off and is zero in the overdoped region of the phase diagram. This indicates that the additionally induced carriers do not populate the band that hosts the superconducting state and that the superconducting order parameter therefore is weakened by the presence of charge carriers in another band. PMID:26169351
Abd Wahib, Siti Munirah; Wan Ibrahim, Wan Aini; Sanagi, Mohd Marsin; Kamboh, Muhammad Afzal; Abdul Keyon, Aemi S
2018-01-12
A facile dispersive-micro-solid phase extraction (D-μ-SPE) method coupled with HPLC for the analysis of selected non-steroidal anti-inflammatory drugs (NSAIDs) in water samples was developed using a newly prepared magnetic sporopollenin-cyanopropyltriethoxysilane (MS-CNPrTEOS) sorbent. Sporopollenin homogenous microparticles of Lycopodium clavatum spores possessed accessible functional groups that facilitated surface modification. Simple modification was performed by functionalization with 3-cyanopropyltriethoxysilane (CNPrTEOS) and magnetite was introduced onto the biopolymer to simplify the extraction process. MS-CNPrTEOS was identified by infrared spectrometrywhile the morphology and the magnetic property were confirmed by scanning electron microscopy (SEM) and vibrating sample magnetometer (VSM), respectively. To maximize the extraction performance of ketoprofen, ibuprofen, diclofenac and mefenamic acid using the proposed MS-CNPrTEOS, important D-μ-SPE parameters were comprehensively optimized. The optimum extraction conditions were sorbent amount, 40 mg; extraction time, 5 min; desorption time; 5 min; sample volume, 15 mL; sample pH 2.0; and salt addition, 2.5% (w/v). The feasibility of the developed method was evaluated using spiked tap water, lake water, river water and waste water samples. Results showed that ketoprofen and ibuprofen were linear in the range of 1.0-1000 μg L -1 whilst diclofenac and mefenamic acid were linear in the range 0.8-500 μg L -1 . The results also showed good detection limits for the studied NSAIDs in the range of 0.21-0.51 μg L -1 and good recoveries for spiked water samples in the range of 85.1-106.4%. The MS-CNPrTEOS proved a promising dispersive sorbent and applicable to facile and rapid assay of NSAIDs in water samples. Copyright © 2017 Elsevier B.V. All rights reserved.
Santana-Viera, Sergio; Guedes-Alonso, Rayco; Sosa-Ferrera, Zoraida; Santana-Rodríguez, José Juan; Kabir, Abuzar; Furton, Kenneth G
2017-12-22
Every year, hundreds of tons of organic pollutants reach the environment through effluents released from wastewater treatment plants worldwide, and many of these compounds have harmful effects on the aquatic ecosystem. A new class of emerging pollutants of high concern is cytostatic drugs, which are designed to treat different types of cancers by attacking cells. Environmental concentrations of cytostatic drugs are known to be in the range of ngL -1 , and for this reason, it is imperative to develop analytical methods of extraction and preconcentration to allow for subsequent instrumental analysis of these drugs. In this work, a rapid, simple and green method for the analysis of seven cytostatic drug compounds that are commonly used in anti-cancer therapies was developed using a novel extraction process based on a powerful miniaturized technique, fabric phase sorptive extraction (FPSE) coupled to ultra-high performance liquid chromatography tandem mass spectrometry (UHPLC-MS/MS). The major parameters that affect the extraction process were optimized. The new method shows good linearity, with a relative standard deviation (RSD) of less than 12%. Relative recoveries higher than 40% were obtained for the studied compounds, and the detection limit of the method was within the values at which these compounds are usually found in environmental water (0.20ngL -1 to 80ngL -1 ). The Limit of Quantification ranged from 0.68 to 267ngL -1 . Significant suppression of the signal due to the matrix effect, a common shortcoming attributed to interference from the extraction process as well as the use of ionization mode, was not observed. Subsequently, the method was applied to real wastewater samples from an effluent obtained from a hospital area and three wastewater treatment plants located in Gran Canaria Island, Spain. Copyright © 2017 Elsevier B.V. All rights reserved.
Gao, Guihua; Li, Sijia; Li, Shuo; Wang, Yudan; Zhao, Pan; Zhang, Xiangyu; Hou, Xiaohong
2018-04-01
In this work, computational and experimental methods were used to study the adsorption of estrogens and glucocorticoids on metal-organic frameworks (MOFs). Computer-aided molecular simulation was applied to predict the adsorption of eight analytes on four MOFs (MIL-101(Cr), MIL-100(Fe), MIL-53(Al), and UiO-66(Zr)) by examining molecular interactions and calculating free binding energies. Subsequently, the four water-stable MOFs were synthesized and evaluated as adsorbents for the target hormones in aqueous solution. As the MOF exhibiting the highest adsorption capacity in both computations and experiments, MIL-53(Al) was chosen as a sorbent to develop a dispersive micro-solid-phase extraction procedure coupled to ultra-performance liquid chromatography tandem mass spectrometry for simultaneous determination of the target analytes in water and human urine samples. Experimental parameters affecting the extraction recoveries, including pH, ionic strength, MIL-53(Al) amount, extraction time, desorption time, and desorption solvent, were optimized. The optimized method provided a linear range of 0.005025-368.6μg/L with good correlation coefficients (0.9982 ≤ r 2 ≤ 0.9992), and limits of detection (S/N = 3) and quantification (S/N = 10) of 0.0015-1.0μg/L and 0.005-1.8μg/L, respectively. The analyte recoveries were in the range of 80.6-98.4% in water samples and 88.4-93.2% in urine samples. Furthermore, MIL-53(Al) showed good stability over 10 extraction cycles (RSD < 10.0%). Good agreement between experimental measurements and computational results showed the potential of this approach for elucidating adsorption mechanisms and predicating extraction efficiencies for MOFs and targets, providing new directions for the development and utilization of MOFs. Copyright © 2017 Elsevier B.V. All rights reserved.
Yan, Hongyuan; Wang, Fang; Han, Dandan; Yang, Gengliang
2012-06-21
A highly selective molecularly imprinted solid-phase extraction (MISPE) combined with liquid chromatography-ultraviolet detection was developed for the simultaneous isolation and determination of four plant hormones including indole-3-acetic acid (IAA), indole-3-propionic acid (IPA), indole-3-butyric acid (IBA) and 1-naphthaleneacetic acid (NAA) in banana samples. The new molecularly imprinted microspheres (MIMs) prepared by aqueous suspension polymerization using 3-hydroxy-2-naphthoic acid and 1-methylpiperazine as mimic templates performed with high selectivity and affinity for the four plant hormones, and applied as selective sorbents of solid-phase extraction could effectively eliminate the interferences of the banana matrix. Good linearity was obtained in a range of 0.04-4.00 μg g(-1) and the recoveries of the four plant hormones at three spiked levels ranged from 78.5 to 107.7% with the relative standard deviations (RSD) of less than 4.6%. The developed MISPE-HPLC protocol obviously improved the selectivity and eliminated the effect of template leakage on quantitative analysis, and could be applied for the determination of plant hormones in complicated biological samples.
Ma, Jie; Chen, Qianliang; Lai, Daowan; Sun, Wenji; Zhang, Tianyou; Ito, Yoichiro
2009-01-01
Coupled with evaporative light scattering detection, high-speed countercurrent chromatography was successfully applied for the first time to separation and purification of four triterpene saponins including esculentoside A, B, C and D from roots of Radix Phytolaccae. The separation was performed with an optimized two-phase solvent system composed of chloroform-methanol-water (4:4:2, v/v) using the lower phase as the mobile phase at a flow rate of 1.5 ml/min,. From 150 mg of crude extract 46.3 mg of esculentoside A, 21.8 mg of esculentoside B, 7.3 mg of esculentoside C, and 13.6 mg of esculentoside D were obtained at purities of 96.7%, 99.2%, 96.5% and 97.8%, respectively, as determined by HPLC analysis. The structures of the four triterpene saponins were identified by ESI-MS,1H NMR and 13C NMR. PMID:20454595
Wu, Lijie; Hu, Mingzhu; Li, Zhanchao; Song, Ying; Yu, Cui; Zhang, Yupu; Zhang, Hanqi; Yu, Aimin; Ma, Qiang; Wang, Ziming
2015-02-01
A novel extraction method, dynamic microwave-assisted extraction coupled with homogeneous ionic liquid microextraction, was developed for the determination of triazine herbicides, including desmetryn, terbumeton, propazine, terbuthylazine, dimethametryn, and dipropetryn in fresh vegetable samples by high performance liquid chromatography (HPLC). In the developed method, 120 μL of 1-butyl-3-methylimidazolium tetrafluoroborate ([C4MIM][BF4]) was added to 10 mL of aqueous solution containing 0.3 g of NaCl to obtained the extraction solvent. Six triazines could be extracted completely within 4 min by the present method. Then, [NH4][PF6] was added into the extract to form a water-insoluble ionic liquid [C4MIM][PF6] via a simple metathesis reaction, and the analytes were enriched into the ionic liquid phase. After centrifugation and dilution with acetonitrile, the resulting solution was analyzed directly by HPLC. The effects of some experimental parameters, including type and volume of ionic liquid, volume of extraction solvent, amount of ion-pairing agent [NH4][PF6], salt concentration, microwave power, and flow rate of extraction solvent on the extraction efficiency were investigated and optimized. Under the optimum experimental conditions, the linearity for determining the analytes was in the range of 2.50-250.00 μg kg(-1), with the correlation coefficients ranging from 0.9989 to 0.9999. When the present method was applied to the analysis of vegetable samples, satisfactory recoveries were obtained in the range of 76.8%-106.9%, and relative standard deviations were lower than 9.8%.
Hogendoom, E A; Huls, R; Dijkman, E; Hoogerbrugge, R
2001-12-14
A screening method has been developed for the determination of acidic pesticides in various types of soils. Methodology is based on the use of microwave assisted solvent extraction (MASE) for fast and efficient extraction of the analytes from the soils and coupled-column reversed-phase liquid chromatography (LC-LC) with UV detection at 228 nm for the instrumental analysis of uncleaned extracts. Four types of soils, including sand, clay and peat, with a range in organic matter content of 0.3-13% and ten acidic pesticides of different chemical families (bentazone, bromoxynil, metsulfuron-methyl, 2,4-D, MCPA, MCPP, 2,4-DP, 2,4,5-T, 2,4-DB and MCPB) were selected as matrices and analytes, respectively. The method developed included the selection of suitable MASE and LC-LC conditions. The latter consisted of the selection of a 5-microm GFF-II internal surface reversed-phase (ISRP, Pinkerton) analytical column (50 x 4.6 mm, I.D.) as the first column in the RAM-C18 configuration in combination with an optimised linear gradient elution including on-line cleanup of sample extracts and reconditioning of the columns. The method was validated with the analysis of freshly spiked samples and samples with aged residues (120 days). The four types of soils were spiked with the ten acidic pesticides at levels between 20 and 200 microg/kg. Weighted regression of the recovery data showed for most analyte-matrix combinations, including freshly spiked samples and aged residues, that the method provides overall recoveries between 60 and 90% with relative standard deviations of the intra-laboratory reproducibility's between 5 and 25%; LODs were obtained between 5 and 50 microg/kg. Evaluation of the data set with principal component analysis revealed that the parameters (i) increase of organic matter content of the soil samples and (ii) aged residues negatively effect the recovery of the analytes.
Boix, C; Ibáñez, M; Fabregat-Safont, D; Morales, E; Pastor, L; Sancho, J V; Sánchez-Ramírez, J E; Hernández, F
2016-01-01
In this work, two analytical methodologies based on liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS) were developed for quantification of emerging pollutants identified in sewage sludge after a previous wide-scope screening. The target list included 13 emerging contaminants (EC): thiabendazole, acesulfame, fenofibric acid, valsartan, irbesartan, salicylic acid, diclofenac, carbamazepine, 4-aminoantipyrine (4-AA), 4-acetyl aminoantipyrine (4-AAA), 4-formyl aminoantipyrine (4-FAA), venlafaxine and benzoylecgonine. The aqueous and solid phases of the sewage sludge were analyzed making use of Solid-Phase Extraction (SPE) and UltraSonic Extraction (USE) for sample treatment, respectively. The methods were validated at three concentration levels: 0.2, 2 and 20 μg L(-1) for the aqueous phase, and 50, 500 and 2000 μg kg(-1) for the solid phase of the sludge. In general, the method was satisfactorily validated, showing good recoveries (70-120%) and precision (RSD < 20%). Regarding the limit of quantification (LOQ), it was below 0.1 μg L(-1) in the aqueous phase and below 50 μg kg(-1) in the solid phase for the majority of the analytes. The method applicability was tested by analysis of samples from a wider study on degradation of emerging pollutants in sewage sludge under anaerobic digestion. The key benefits of these methodologies are: • SPE and USE are appropriate sample procedures to extract selected emerging contaminants from the aqueous phase of the sewage sludge and the solid residue. • LC-MS/MS is highly suitable for determining emerging contaminants in both sludge phases. • Up to our knowledge, the main metabolites of dipyrone had not been studied before in sewage sludge.
Tomková, Jana; Ondra, Peter; Kocianová, Eva; Václavík, Jan
2017-07-01
This paper presents a method for the determination of acebutolol, betaxolol, bisoprolol, metoprolol, nebivolol and sotalol in human serum by liquid-liquid extraction and ultra-high-performance liquid chromatography coupled with ultra-high-resolution TOF mass spectrometry. After liquid-liquid extraction, beta blockers were separated on a reverse-phase analytical column (Acclaim RS 120; 100 × 2.1 mm, 2.2 μm). The total run time was 6 min for each sample. Linearity, limit of detection, limit of quantification, matrix effects, specificity, precision, accuracy, recovery and sample stability were evaluated. The method was successfully applied to the therapeutic drug monitoring of 108 patients with hypertension. This method was also used for determination of beta blockers in 33 intoxicated patients. Copyright © 2016 John Wiley & Sons, Ltd.
Laboureur, Laurent; Bonneau, Natacha; Champy, Pierre; Brunelle, Alain; Touboul, David
2017-11-01
Acetogenins are plant polyketides known to be cytotoxic and proposed as antitumor candidates. They are also suspected to be alimentary neurotoxins. Their occurrence as complex mixtures renders their dereplication and structural identification difficult using liquid chromatography coupled to tandem mass spectrometry and efforts are required to improve the methodology. To develop a supercritical fluid chromatography (SFC) high-resolution tandem mass spectrometry method, involving lithium post-column cationisation, for the structural characterisation of Annonaceous acetogenins in crude extracts. The seeds of Annona muricata L. were extracted with methanol. Supercritical fluid chromatography of the extract, using a 2-ethylpyridine stationary phase column, was monitored using a high-resolution quadrupole time-of-flight mass spectrometer. Lithium iodide was added post-column in the make-up solvent. For comparison, the same extract was analysed using high-pressure liquid chromatography coupled to the same mass spectrometer, with a column based on solid core particles. Sensitivity was similar for both HPLC and SFC approaches. Retention behaviour and fragmentation pathways of three different isomer groups are described. A previously unknown group of acetogenins was also evidenced for the first time. The use of SFC-MS/MS allows the reduction of the time of analysis, of environmental impact and an increase in the chromatographic resolution, compared to liquid chromatography. This new methodology enlightened a new group of acetogenins, isomers of montanacin-D. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.
Rodrigues, C; Portugal, F C M; Nogueira, J M F
2012-01-30
Static headspace sorptive extraction using polyurethane foams (HSSE(PU)) followed by gas chromatography coupled to mass spectrometry is proposed for volatile analysis. The application of this novel analytical approach to characterize the volatiles profile from roasted coffee samples, selected as model system, revealed remarkable advantages under convenient experimental conditions. The comparison of HSSE(PU) with other well-established procedures, such as headspace sorptive extraction using polydimethylsiloxane (HSSE(PDMS)) and headspace solid phase microextraction using carboxen/polydimethylsiloxane fibers (HS-SPME(CAR/PDMS)), showed that the former presented much higher capacity, sensitivity and even selectivity, where larger abundance and number of roasted coffee volatile compounds (e.g. furans, pyrazines, ketones, acids and pyrroles) could be achieved, under similar experimental conditions. The data presented herein proved, for the first time, that PU foams present great performance for static headspace sorption-based procedures, showing to be an alternative polymeric phase for volatile analysis. Copyright © 2011 Elsevier B.V. All rights reserved.
Wei, Z; Sandron, S; Townsend, A T; Nesterenko, P N; Paull, B
2015-04-01
Cobalt magnetic nanoparticles surface functionalised with iminodiacetic acid were evaluated as a nano-particulate solid phase extraction absorbent for copper ions (Cu(2+)) from environmental water samples. Using an external magnetic field, the collector nanoparticles could be separated from the aqueous phase, and adsorbed ions simply decomplexed using dilute HNO3. Effects of pH, buffer concentration, sample and sorbent volume, extraction equilibrium time, and interfering ion concentration on extraction efficiency were investigated. Optimal conditions were then applied to the extraction of Cu(2+) ions from natural water samples, prior to their quantitation using high-performance chelation ion chromatography. The limits of detection (LOD) of the combined extraction and chromatographic method were ~0.1 ng ml(-1), based upon a 100-fold preconcentration factor (chromatographic performance; LOD=9.2 ng ml(-1) Cu(2+)), analytical linear range from 20 to 5000 ng mL(-1), and relative standard deviations=4.9% (c=1000 ng ml(-1), n=7). Accuracy and precision of the combined approach was verified using a certified reference standard estuarine water sample (SLEW-2) and comparison of sample determinations with sector field inductively coupled plasma mass spectrometry. Recoveries from the addition of Cu(2+) to impacted estuarine and rain water samples were 103.5% and 108.5%, respectively. Coastal seawater samples, both with and without prior UV irradiation and dissolved organic matter removal were also investigated using the new methodology. The effect of DOM concentration on copper availability was demonstrated. Copyright © 2015. Published by Elsevier B.V.
Li, FuKai; Gong, AiJun; Qiu, LiNa; Zhang, WeiWei; Li, JingRui; Liu, Yu; Liu, YuNing; Yuan, HuiTing
2017-01-01
The determination of trace rare-earth elements (REEs) can be used for the assessment of environmental pollution, and is of great significance to the study of toxicity and toxicology in animals and plants. N, N, N', N'-tetraoctyl diglycolamide (TODGA) is an environmental friendly extractant that is highly selective to REEs. In this study, an analytical method was developed for the simultaneous determination of 16 trace REEs in simulated water samples by inductively coupled plasma optical emission spectroscopy (ICP-OES). With this method, TODGA was used as the extractant to perform the liquid-liquid extraction (LLE) sample pretreatment procedure. All 16 REEs were extracted from a 3 M nitric acid medium into an organic phase by a 0.025 M TODGA petroleum ether solution. A 0.03 M ethylenediaminetetraacetic acid disodium salt (EDTA) solution was used for back-extraction to strip the REEs from the organic phase into the aqueous phase. The aqueous phase was concentrated using a vacuum rotary evaporator and the concentration of the 16 REEs was detected by ICP-OES. Under the optimum experimental conditions, the limits of detection (3σ, n = 7) for the REEs ranged from 0.0405 ng mL-1 (Nd) to 0.5038 ng mL-1 (Ho). The relative standard deviations (c = 100 ng mL-1, n = 7) were from 0.5% (Eu) to 4.0% (Tm) with a linear range of 4-1000 ng mL-1 (R2 > 0.999). The recoveries of 16 REEs ranged from 95% to 106%. The LLE-ICP-OES method established in this study has the advantages of simple operation, low detection limits, fast analysis speed and the ability to simultaneously determine 16 REEs, thereby acting as a viable alternative for the simultaneous detection of trace amounts of REEs in water samples.
Li, FuKai; Qiu, LiNa; Zhang, WeiWei; Li, JingRui; Liu, Yu; Liu, YuNing; Yuan, HuiTing
2017-01-01
The determination of trace rare-earth elements (REEs) can be used for the assessment of environmental pollution, and is of great significance to the study of toxicity and toxicology in animals and plants. N, N, N′, N′-tetraoctyl diglycolamide (TODGA) is an environmental friendly extractant that is highly selective to REEs. In this study, an analytical method was developed for the simultaneous determination of 16 trace REEs in simulated water samples by inductively coupled plasma optical emission spectroscopy (ICP-OES). With this method, TODGA was used as the extractant to perform the liquid-liquid extraction (LLE) sample pretreatment procedure. All 16 REEs were extracted from a 3 M nitric acid medium into an organic phase by a 0.025 M TODGA petroleum ether solution. A 0.03 M ethylenediaminetetraacetic acid disodium salt (EDTA) solution was used for back-extraction to strip the REEs from the organic phase into the aqueous phase. The aqueous phase was concentrated using a vacuum rotary evaporator and the concentration of the 16 REEs was detected by ICP-OES. Under the optimum experimental conditions, the limits of detection (3σ, n = 7) for the REEs ranged from 0.0405 ng mL-1 (Nd) to 0.5038 ng mL-1 (Ho). The relative standard deviations (c = 100 ng mL-1, n = 7) were from 0.5% (Eu) to 4.0% (Tm) with a linear range of 4–1000 ng mL-1 (R2 > 0.999). The recoveries of 16 REEs ranged from 95% to 106%. The LLE-ICP-OES method established in this study has the advantages of simple operation, low detection limits, fast analysis speed and the ability to simultaneously determine 16 REEs, thereby acting as a viable alternative for the simultaneous detection of trace amounts of REEs in water samples. PMID:28945788
Guedes-Alonso, Rayco; Sosa-Ferrera, Zoraida; Santana-Rodríguez, José Juan
2017-12-15
Steroid hormones produce adverse effects on biota as well as bioaccumulation in fish and seafood, making it necessary to develop methodologies to evaluate these compounds in samples related to the food chain. This work presents an analytical method for evaluating 15 steroid hormones in fish tissue. It is based on microwave-assisted extraction and solid-phase extraction coupled to ultra-high-performance liquid chromatography tandem mass spectrometry (MAE-SPE-UHPLC-MS/MS). The proposed method shows appropriate detection limits (0.14-49.0ngg -1 ), recoveries in the range of 50% and good repeatability. After optimization, the method was applied to different tissues from two small fishes of the Canary Islands that constitute an important level of the food web (Boops boops and Sphoeroides marmoratus) and were exposed to the outfall of the Las Palmas de Gran Canaria wastewater treatment plant. The concentrations of eight detected compounds ranged from below the quantification limits to 3.95μgg -1 . Copyright © 2017 Elsevier Ltd. All rights reserved.
Wang, He-xing; Wang, Bin; Zhou, Ying; Jiang, Qing-wu
2013-05-01
Steroid hormone levels in human urine are convenient and sensitive indicators for the impact of phthalates and/or bisphenol A (BPA) exposure on the human steroid hormone endocrine system. In this study, a rapid and sensitive method for determination of 14 phthalate metabolites, BPA, and ten endogenous steroid hormones in urine was developed and validated on the basis of ultra-performance liquid chromatography coupled with electrospray ionization triple quadrupole mass spectrometry. The optimized mixed-mode solid phase-extraction separated the weakly acidic or neutral BPA and steroid hormones from acidic phthalate metabolites in urine: the former were determined in positive ion mode with a methanol/water mobile phase containing 10 mM ammonium formate; the latter were determined in negative ion mode with a acetonitrile/water mobile phase containing 0.1 % acetic acid, which significantly alleviated matrix effects for the analysis of BPA and steroid hormones. Dansylation of estrogens and BPA realized simultaneous and sensitive analysis of the endogenous steroid hormones and BPA in a single chromatographic run. The limits of detection were less than 0.84 ng/mL for phthalate metabolites and less than 0.22 ng/mL for endogenous steroid hormones and BPA. This proposed method had satisfactory precision and accuracy, and was successfully applied to the analyses of human urine samples. This method could be valuable when investigating the associations among endocrine-disrupting chemicals, endogenous steroid hormones, and relevant adverse outcomes in epidemiological studies.
NASA Astrophysics Data System (ADS)
Alliot, Fabrice; Moreau-Guigon, Elodie; Bourges, Catherine; Desportes, Annie; Teil, Marie-Jeanne; Blanchard, Martine; Chevreuil, Marc
2014-08-01
A number of semi-volatile compounds occur in indoor air most of them being considered as potent endocrine disruptors and thus, exerting a possible impact upon health. To assess their concentration levels in indoor air, we developed and validated a method for sampling and multi-residue analysis of 58 compounds including phthalates, polycyclic aromatic hydrocarbons (PAHs), polybromodiphenylethers (PBDEs), polychlorobiphenyls (PCBs), parabens, bisphenol A (BPA) and tetrabromobisphenol A (TBBPA) in gaseous and particulate phases of air. We validated each step of procedures from extraction until analysis. Matrice spiking were performed at extraction, fractionation and purification stages. The more volatile compounds were analyzed with a gas chromatography system coupled with a mass spectrometer (GC/MS) or with a tandem mass spectrometer (GC/MS/MS). The less volatile compounds were analyzed with a liquid chromatography system coupled with a tandem mass spectrometer (LC/MS/MS). Labeled internal standard method was used ensuring high quantification accuracy. The instrumental detection limits were under 1 pg for all compounds and therefore, a limit of quantification averaging 1 pg m-3 for the gaseous and the particulate phases and a volume of 150 m3, except for phthalates, phenol compounds and BDE-209. Satisfactory recoveries were found except for phenol compounds. That method was successfully applied to several indoor air samples (office, apartment and day nursery) and most of the targeted compounds were quantified, mainly occurring in the gaseous phase. The most abundant were phthalates (up to 918 ng m-3 in total air), followed by PCBs > parabens > BPA > PAHs > PBDEs.
Kamaruzaman, Sazlinda; Sanagi, Mohd Marsin; Yahaya, Noorfatimah; Wan Ibrahim, Wan Aini; Endud, Salasiah; Wan Ibrahim, Wan Nazihah
2017-11-01
A new facile magnetic micro-solid-phase extraction coupled to gas chromatography and mass spectrometry detection was developed for the extraction and determination of selected antidepressant drugs in biological fluids using magnetite-MCM-41 as adsorbent. The synthesized sorbent was characterized by several spectroscopic techniques. The maximum extraction efficiency for extraction of 500 μg/L antidepressant drugs from aqueous solution was obtained with 15 mg of magnetite-MCM-41 at pH 12. The analyte was desorbed using 100 μL of acetonitrile prior to gas chromatography determination. This method was rapid in which the adsorption procedure was completed in 60 s. Under the optimized conditions using 15 mL of antidepressant drugs sample, the calibration curve showed good linearity in the range of 0.05-500 μg/L (r 2 = 0.996-0.999). Good limits of detection (0.008-0.010 μg/L) were obtained for the analytes with good relative standard deviations of <8.0% (n = 5) for the determination of 0.1, 5.0, and 500.0 μg/L of antidepressant drugs. This method was successfully applied to the determination of amitriptyline and chlorpromazine in plasma and urine samples. The recoveries of spiked plasma and urine samples were in the range of 86.1-115.4%. Results indicate that magnetite micro-solid-phase extraction with gas chromatography and mass spectrometry is a convenient, fast, and economical method for the extraction and determination of amitriptyline and chlorpromazine in biological samples. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Taylor, L.T.
Because it has been our goal to interface the supercritical fluid chromatograph with a Fourier transform infrared spectrometer we have initially chosen packed columns due to their increased sample capacities, and supercritical CO/sub 2/ because of its infrared transparency. This paper compares two sampling techniques that can be utilized in packed column supercritical fluid Chromatography (SFC). Traditional sample introduction is accomplished using an injector with a sample loop. The loop is filled with the appropriate amount of material, and subsequently inserted into the mobile phase path. In most cases the sample must be either dissolved or extracted into an appropriatemore » solvent for such sample introduction. Note that unlike HPLC, where the solvent can be the same as the mobile phase, traditional sampling with SFC must use a solvent that is very different from the mobile phase. As a result, solvent peaks are almost always present, especially with universal detectors like FTIR. An alternative method is described here whereby both extraction of the sample and introduction of the extract onto the column is accomplished on-line using only the supercritical fluid mobile phase. This sampling technique is made possible by a simple valving scheme which ties directly the extraction vessel, the injector, the packed column and the detector. This technique has several advantages over the traditional methods, not the least of which is the absence of a large amount of foreign solvent introduced on the column. 11 refs., 7 figs.« less
Wang, Xinran; Yang, Shupeng; Li, Yi; Zhang, Jinzhen; Jin, Yue; Zhao, Wen; Zhang, Yongxin; Huang, Jingping; Wang, Peng; Wu, Cuiling; Zhou, Jinhui
2018-03-23
A robust and sensitive method of solid-phase extraction followed by liquid chromatography-tandem mass spectrometry (LC-MS/MS) was established and performed for the simultaneous determination of eleven aminoglycosides (AGs) in royal jelly and honey. After sample extraction by a phosphate buffer containing trichloroacetic acid (TCA) and ethylenediaminetetracetic acid disodium salt (Na 2 EDTA), the extraction solution was subjected to a parallel solid-phase extraction for clean-up prior to the LC-MS/MS analysis. The same method was applied to analyze two completely different matrices, honey and royal jelly. Good sensitivity, repeatability, and recovery were obtained by using the mobile phase without an ion-pairing reagent such as heptafluorobutyric acid (HFBA) or sodium heptanesulfonate. The calibration curves of the honey and royal jelly samples exhibited a good linear response (R 2 > 0.99) at six concentrations in the range of 10-1000 μg/mL. The limit of quantification (LOQ) of the AGs ranged from 10 to 25 μg/kg in the honey and from 12.5 to 25 μg/kg in the royal jelly. The recoveries of the AGs for the honey and royal jelly samples were in the range of 79.48% to 108.95% and 74.61% to 113.70% respectively and the relative standard deviations (RSDs) were between 1.23% and 9.59%, and between 1.51% and 9.98%, respectively. The proposed approach has been allowed in China as a reference method for the simultaneous determination of eleven AGs in honey and royal jelly. Copyright © 2018 Elsevier B.V. All rights reserved.
Alexovič, Michal; Horstkotte, Burkhard; Solich, Petr; Sabo, Ján
2016-02-11
A critical overview on automation of modern liquid phase microextraction (LPME) approaches based on the liquid impregnation of porous sorbents and membranes is presented. It is the continuation of part 1, in which non-dispersive LPME techniques based on the use of the extraction phase (EP) in the form of drop, plug, film, or microflow have been surveyed. Compared to the approaches described in part 1, porous materials provide an improved support for the EP. Simultaneously they allow to enlarge its contact surface and to reduce the risk of loss by incident flow or by components of surrounding matrix. Solvent-impregnated membranes or hollow fibres are further ideally suited for analyte extraction with simultaneous or subsequent back-extraction. Their use can therefore improve the procedure robustness and reproducibility as well as it "opens the door" to the new operation modes and fields of application. However, additional work and time are required for membrane replacement and renewed impregnation. Automation of porous support-based and membrane-based approaches plays an important role in the achievement of better reliability, rapidness, and reproducibility compared to manual assays. Automated renewal of the extraction solvent and coupling of sample pretreatment with the detection instrumentation can be named as examples. The different LPME methodologies using impregnated membranes and porous supports for the extraction phase and the different strategies of their automation, and their analytical applications are comprehensively described and discussed in this part. Finally, an outlook on future demands and perspectives of LPME techniques from both parts as a promising area in the field of sample pretreatment is given. Copyright © 2015 Elsevier B.V. All rights reserved.
Wang, Zhaokun; Zhang, Xue; Jiang, Shenmeng; Guo, Xingjie
2018-04-01
In this work, the magnetic multiwalled carbon nanotubes (Mag-MWCNTs) were prepared by self-assembly method and characterized by scanning electron microscopy, X-ray powder diffraction, energy dispersive X-ray and vibrating sample magnetometer. Then, these synthetic Mag-MWCNTs were used as sorbents to extract five β-blockers (atenolol, metoprolol, esmolol, pindolol and arotinolol) by magnetic solid-phase extraction. The target analytes adsorbed on Mag-MWCNTs were eluted and determined on a chiral α-acid glycoprotein column coupled with a triple quadrupole mass spectrometry. Eventually, the proposed method was applied to the analysis of the enantiomeric composition of the studied β-blockers in three environmental samples, including river water, influent wastewater and effluent wastewater. Method detection and quantification limits for all enantiomers were in the range of 0.50-1.45 and 1.63-3.75ng/L, respectively. Satisfactory recovery (82.9-95.6%), good intra-day precision (RSD 0.4-10.4%) and inter-day precision (RSD 2.9-7.4%) were also obtained. With numerous advantages such as simplicity of operation, rapidity and high enrichment factor, the newly developed method has potential to assess the enantioselectivity of chiral drugs in ecotoxicity and biodegradation processes, which is also a new expanded application of Mag-MWCNTs in the environmental analysis. Copyright © 2017 Elsevier B.V. All rights reserved.
Liaud, Céline; Brucher, Michel; Schummer, Claude; Coscollà, Clara; Wolff, Hélène; Schwartz, Jean-Jacques; Yusà, Vicent; Millet, Maurice
2016-10-02
Atmospheric samples have been collected between 14 March and 12 September 2012 on a 2-week basis (15 days of sampling and exchange of traps each 7 days) in Strasbourg (east of France) for the analysis of 43 pesticides. Samples (particle and gas phases) were separately extracted using Accelerated Solvent Extraction (ASE) and pre-concentrated by Solid Phase Micro-Extraction (SPME) before analysis by gas chromatography coupled to tandem mass spectrometry (GC-MS/MS). Four SPME consecutive injections at distinct temperatures were made in order to increase the sensitivity of detection for the all monitored pesticides. Currently used detected pesticides can be grouped in four classes; those used in maize crops (acetochlor, benoxacor, dicamba, s-metolachlor, pendimethalin, and bromoxynil), in cereal crops (benoxacor, chlorothalonil, fenpropimorph, and propiconazole), in vineyards (tebuconazole), and as herbicides for orchards, meadows of green spaces (2,4-MCPA, trichlopyr). This is in accordance with the diversity of crops found in the Alsace region and trends observed are in accordance with the period of application of these pesticides. Variations observed permit also to demonstrate that the long time sampling duration used in this study is efficient to visualize temporal variations of airborne pesticides concentrations. Then, long time high-volume sampling could be a simple method permitting atmospheric survey of atmospheric contamination without any long analysis time and consequently low cost.
Ma, Jiping; Jiang, Lianhua; Wu, Gege; Xia, Yan; Lu, Wenhui; Li, Jinhua; Chen, Lingxin
2016-09-30
Magnetic solid-phase extraction (MSPE) using magnetic multi-walled carbon nanotubes (mag-MWCNTs) as adsorbents, coupled with high-performance liquid chromatography-diode-array detector (HPLC-DAD), was developed for the simultaneous separation and determination of six types of sulfonylurea herbicides (SUs) in environmental water samples. Several variables affecting MSPE efficiency were systematically investigated, including the type and volume of desorption solvent, sample solution pH, salt concentration, amount of mag-MWCNTs, and extraction and desorption time. Response surface was employed to assist in the MSPE optimization. Under optimized conditions, excellent linearity was achieved in the range of 0.05-5.0μg/L for all six SUs, with coefficients of correlation r>0.9994, and preconcentration factors ranging from 178 to 210. Limits of detection and quantification were 0.01-0.04μg/L and 0.03-0.13μg/L, respectively. The intra-day and inter-day precision (relative standard deviations, n=6, %) at three spiked levels were 2.0-11.0% and 2.1-12.9% in terms of peak area, respectively. The method recoveries at three fortified concentrations were obtained within 76.7-106.9% for reservoir water samples and 78.2-105.4% for tap water samples. The developed MSPE-HPLC method demonstrated high sensitivity, repeatability, simplicity, rapidity, and excellent practical applicability. Copyright © 2016 Elsevier B.V. All rights reserved.
Pschenitza, Michael; Hackenberg, Rudolf; Niessner, Reinhard; Knopp, Dietmar
2014-01-01
This paper describes the development of a molecularly imprinted polymer-based solid phase extraction (MISPE) method coupled with enzyme-linked immunosorbent assay (ELISA) for determination of the PAH benzo[a]pyrene (B[a]P) in vegetable oils. Different molecularly imprinted polymers (MIPs) were prepared using non-covalent 4-vinylpyridine/divinylbenzene co-polymerization at different ratios and dichloromethane as porogen. Imprinting was done with a template mixture of phenanthrene and pyrene yielding a broad-specific polymer for PAHs with a maximum binding capacity (Q) of ∼32 μg B[a]P per 50 mg of polymer. The vegetable oil/n-hexane mixture (1:1, (v/v)) was pre-extracted with acetonitrile, the solvent evaporated, the residue reconstituted in n-hexane and subjected to MISPE. The successive washing with n-hexane and isopropanol revealed most suitable to remove lipid matrix constituents. After elution of bound PAHs from MISPE column with dichloromethane, the solvent was evaporated, the residue reconstituted with dimethyl sulfoxide and diluted 100-fold with methanol/water (10:90, (v/v)) for analysis of B[a]P equivalents with an ELISA. The B[a]P recovery rates in spiked vegetable oil samples of different fatty acid composition were determined between 63% and 114%. The presence of multiple PAHs in the oil sample, because of MIP selectivity and cross-reactivity of the ELISA, could yield overestimated B[a]P values. PMID:24887045
Analysis of psilocin, bufotenine and LSD in hair.
Martin, Rafaela; Schürenkamp, Jennifer; Gasse, Angela; Pfeiffer, Heidi; Köhler, Helga
2015-03-01
A method for the simultaneous extraction of the hallucinogens psilocin, bufotenine, lysergic acid diethylamide (LSD) as well as iso-LSD, nor-LSD and O-H-LSD from hair with hydrochloride acid and methanol is presented. Clean-up of the hair extracts is performed with solid phase extraction using a mixed-mode cation exchanger. Extracts are measured with liquid chromatography coupled with electrospray tandem mass spectrometry. The method was successfully validated according to the guidelines of the 'Society of Toxicological and Forensic Chemistry' (GTFCh). To obtain reference material hair was soaked in a solution of the analytes in dimethyl sulfoxide/methanol to allow incorporation into the hair. These fortified hair samples were used for method development and can be employed as quality controls. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Yang, Qin; Wang, Yuzhi; Zhang, Hongmei; Xu, Kaijia; Wei, Xiaoxiao; Xu, Panli; Zhou, Yigang
2017-11-01
A novel magnetic extractant, PEG 4000 modified Fe 3 O 4 nanomaterial that coated with dianionic amino acid ionic liquid (Fe 3 O 4 @PEG@DAAAIL), was successfully synthesized and characterized. X-ray diffraction (XRD), transmission electron microscope (TEM), vibrating sample magnetometer (VSM), fourier transform infrared spectrometry (FT-IR), thermal gravimetric analysis (TGA) and zeta potentials were used to confirm that the novel nanocomposite was successfully synthesized. Subsequently, the prepared Fe 3 O 4 @PEG@DAAAIL nanocomposite was used as the extractant for trypsin coupled with magnetic solid-phase extraction (MSPE). The concentrations of trypsin in the supernatant were detected by UV-vis spectrophotometer at 278nm. The extraction ability turned out to be better than the other four kinds of extractants prepared in this work. Furthermore, the influence of a series of factors, such as extraction time and temperature, initial trypsin concentration, the value of pH and ionic strength, was systematically investigated. Under the optimal extraction condition, the extraction capacity for trypsin could reach up to 718.73mg/g, absolutely higher than that of other adsorbents reported. This satisfactory extraction capacity could be maintained unchangeable after at least eight days, and kept over 90% of initial extraction capacity after eight recycles. What's more, the activity of trypsin after extraction retained 92.29% of initial activity, verifying the biocompatibility of the prepared extractant. Finally, the developed Fe 3 O 4 @PEG@DAAAIL-MSPE method was successfully applied to the real sample analysis with satisfactory results. All of above proves the potential value of Fe 3 O 4 @PEG@DAAAIL-MSPE in the analysis of biomass. Copyright © 2017 Elsevier B.V. All rights reserved.
Cazorla-Reyes, Rocío; Fernández-Moreno, José Luis; Romero-González, Roberto; Frenich, Antonia Garrido; Vidal, José Luis Martínez
2011-07-15
A new multiresidue method has been developed and validated for the simultaneous extraction of more than two hundred pesticides, including non-polar and polar pesticides (carbamates, organochlorine, organophosphorous, pyrethroids, herbicides and insecticides) in urine at trace levels by gas and ultra high pressure liquid chromatography coupled to ion trap and triple quadrupole mass spectrometry, respectively (GC-IT-MS/MS, UHPLC-QqQ-MS/MS). Non-polar and polar pesticides were simultaneously extracted from urine samples by a simple and fast solid phase extraction (SPE) procedure using C(18) cartridges as sorbent, and dichloromethane as elution solvent. Recovery was in the range of 60-120%. Precision values expressed as relative standard deviation (RSD) were lower than 25%. Identification and confirmation of the compounds were performed by the use of retention time windows, comparison of spectra (GC-amenable compounds) or the estimation of the ion ratio (LC-amenable compounds). For GC-amenable pesticides, limits of detection (LODs) ranged from 0.001 to 0.436 μg L(-1) and limits of quantification (LOQs) from 0.003 to 1.452 μg L(-1). For LC-amenable pesticides, LODs ranged from 0.003 to 1.048 μg L(-1) and LOQs ranged from 0.011 to 3.494 μg L(-1). Finally, the optimized method was applied to the analysis of fourteen real samples of infants from agricultural population. Some pesticides such as methoxyfenozide, tebufenozide, piperonyl butoxide and propoxur were found at concentrations ranged from 1.61 to 24.4 μg L(-1), whereas methiocarb sulfoxide was detected at trace levels in two samples. Copyright © 2011 Elsevier B.V. All rights reserved.
Bie, Zhenying; Lu, Wei; Zhu, You; Chen, Yusong; Ren, Hubo; Ji, Lishun
2017-01-27
A fully automated, rapid, and reliable method for simultaneous determination of six carcinogenic primary aromatic amines (AAs), including o-toluidine (o-TOL), 2, 6-dimethylaniline (2, 6-DMA), o-anisidine (o-ASD), 1-naphthylamine (1-ANP), 2-naphthylamine (2-ANP), and 4-aminobiphenyl (4-ABP), in mainstream cigarette smoke was established. The proposed method was based on two-dimensional online solid phase extraction combined with liquid chromatography tandem mass spectrometry (SPE/LC-MS/MS). The particulate phase of the mainstream cigarette smoke was collected on a Cambridge filter pad and pretreated via ultrasonic extraction with 2% formic acid (FA), while the gas phase was trapped by 2% FA without pretreatment for determination. The two-dimensional online SPE comprised of two cartridges with different absorption characteristics was applied for sample pretreatment. Analysis was performed by liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS) under multiple reaction monitoring mode. Each sample required about 0.5h for solid phase extraction and analysis. The limit of detections (LODs) for six AAs ranged from 0.04 to 0.58ng/cig and recoveries were within 84.5%-122.9%. The relative standard deviations of intra- and inter-day tests for 3R4F reference cigarette were less than 6% and 7%, respectively, while no more than 7% and 8% separately for a type of Virginia cigarette. The proposed method enabled minimum sample pretreatment, full automation, and high throughput with high selectivity, sensitivity, and accuracy. As a part of the validation procedure, fifteen brands of cigarettes were tested by the designed method. Copyright © 2016 Elsevier B.V. All rights reserved.
Coupling geodynamic with thermodynamic modelling for reconstructions of magmatic systems
NASA Astrophysics Data System (ADS)
Rummel, Lisa; Kaus, Boris J. P.; White, Richard
2016-04-01
Coupling geodynamic with petrological models is fundamental for understanding magmatic systems from the melting source in the mantle to the point of magma crystallisation in the upper crust. Most geodynamic codes use very simplified petrological models consisting of a single, fixed, chemistry. Here, we develop a method to better track the petrological evolution of the source rock and corresponding volcanic and plutonic rocks by combining a geodynamic code with a thermodynamic model for magma generation and evolution. For the geodynamic modelling a finite element code (MVEP2) solves the conservation of mass, momentum and energy equations. The thermodynamic modelling of phase equilibria in magmatic systems is performed with pMELTS for mantle-like bulk compositions. The thermodynamic dependent properties calculated by pMELTS are density, melt fraction and the composition of the liquid and solid phase in the chemical system: SiO2-TiO2-Al2O3-Fe2O3-Cr2O3-FeO-MgO-CaO-Na2O-K2O-P2O5-H2O. In order to take into account the chemical depletion of the source rock with increasing melt extraction events, calculation of phase diagrams is performed in two steps: 1) With an initial rock composition density, melt fraction as well as liquid and solid composition are computed over the full upper mantle P-T range. 2) Once the residual rock composition (equivalent to the solid composition after melt extraction) is significantly different from the initial rock composition and the melt fraction is lower than a critical value, the residual composition is used for next calculations with pMELTS. The implementation of several melt extraction events take the change in chemistry into account until the solidus is shifted to such high temperatures that the rock cannot be molten anymore under upper mantle conditions. An advantage of this approach is that we can track the change of melt chemistry with time, which can be compared with natural constraints. In the thermo-mechanical code the thermodynamic dependent properties from pre-computed phase diagrams are carried by each particle using marker-in-cell method . Thus the physical and chemical properties can change locally as a function of previous melt extraction events, pressure and temperature conditions. After each melt extraction event, the residual rock composition is compared with the bulk composition of previous computed phase diagrams, so that the used phase diagram is replaced by the phase diagram with the closest bulk chemistry. In the thermo-mechanical code, the melt is extracted directly to the surface as volcanites and within the crust as plutonites. The density of the crust and new generated crust is calculated with the thermodynamic modelling tool Perple_X. We have investigated the influence of several input parameters on the magma composition to compare it with real rock samples from Eifel (West-Germany). In order to take the very inhomogeneous chemistry of European mantle into account, we include not only primitive mantle but also metasomatised mantle fragments in the melting source of a plume (Eifel plume).
Zhang, Ming-Yue; Wang, Man-Man; Hao, Yu-Lan; Shi, Xin-Ran; Wang, Xue-Sheng
2016-05-01
A simple, effective, and robust magnetic solid-phase extraction method was developed using magnetite/reduced graphene oxide nanoparticles as the adsorbent for the simultaneous determination of Sudan dyes (I, II, III, and IV) in foodstuffs. The magnetite/reduced graphene oxide nanoparticles were characterized by X-ray diffraction, scanning electron microscopy, and vibrating sample magnetometry. The extraction parameters including extraction time, elution solution, and elution time and volume were investigated in detail. Such magnetite/reduced graphene oxide nanoparticles based magnetic solid-phase extraction in combination with high-performance liquid chromatography and variable wavelength detection gave the detection limits of 3-6 μg/kg for Sudan I-IV in chili sauce, tomato sauce, chili powder, and chili flake samples. The recoveries were 79.6-108% at three spiked levels with the intra- and inter-day relative standard deviations of 1.2-8.6 and 4.5-9.6%, respectively. The feasibility was further performed by a comparison with commercial alumina-N. This method is suitable for the routine analysis of Sudan dyes due to its sensitivity, simplicity, and low cost. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
NASA Technical Reports Server (NTRS)
Cross, James H., II
1990-01-01
The study, formulation, and generation of structures for Ada (GRASP/Ada) are discussed in this second phase report of a three phase effort. Various graphical representations that can be extracted or generated from source code are described and categorized with focus on reverse engineering. The overall goal is to provide the foundation for a CASE (computer-aided software design) environment in which reverse engineering and forward engineering (development) are tightly coupled. Emphasis is on a subset of architectural diagrams that can be generated automatically from source code with the control structure diagram (CSD) included for completeness.
van Ede, Freek; Maris, Eric
2016-01-01
Oscillatory neuronal activity is implicated in many cognitive functions, and its phase coupling between sensors may reflect networks of communicating neuronal populations. Oscillatory activity is often studied using extracranial recordings and compared between experimental conditions. This is challenging, because there is overlap between sensor-level activity generated by different sources, and this can obscure differential experimental modulations of these sources. Additionally, in extracranial data, sensor-level phase coupling not only reflects communicating populations, but can also be generated by a current dipole, whose sensor-level phase coupling does not reflect source-level interactions. We present a novel method, which is capable of separating and characterizing sources on the basis of their phase coupling patterns as a function of space, frequency and time (trials). Importantly, this method depends on a plausible model of a neurobiological rhythm. We present this model and an accompanying analysis pipeline. Next, we demonstrate our approach, using magnetoencephalographic (MEG) recordings during a cued tactile detection task as a case study. We show that the extracted components have overlapping spatial maps and frequency content, which are difficult to resolve using conventional pairwise measures. Because our decomposition also provides trial loadings, components can be readily contrasted between experimental conditions. Strikingly, we observed heterogeneity in alpha and beta sources with respect to whether their activity was suppressed or enhanced as a function of attention and performance, and this happened both in task relevant and irrelevant regions. This heterogeneity contrasts with the common view that alpha and beta amplitude over sensory areas are always negatively related to attention and performance. PMID:27336159
Bagheri, Hasan; Zavareh, Alireza Fakhari; Koruni, Mohammad Hossein
2016-03-01
In the present study, graphene oxide reinforced two-phase electromembrane extraction (EME) coupled with gas chromatography was applied for the determination of methamphetamine as a model analyte in biological samples. The presence of graphene oxide in the hollow fiber wall can increase the effective surface area, interactions with analyte and polarity of support liquid membrane that leads to an enhancement in the analyte migration. To investigate the influence of the presence of graphene oxide in the support liquid membrane on the extraction efficiency, a comparative study was performed between graphene oxide and graphene oxide/EME methods. The extraction parameters such as type of organic solvent, pH of the donor phase, stirring speed, time, voltage, salt addition and the concentration of graphene oxide were optimized. Under the optimum conditions, the proposed microextraction technique provided low limit of detection (2.4 ng/mL), high preconcentration factor (195-198) and high relative recovery (95-98.5%). Finally, the method was successfully employed for the determination of methamphetamine in urine and hair samples. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Teixeira, Roseane Andrade; Flores, Diego Hernando Ângulo; da Silva, Ricky Cássio Santos; Dutra, Flávia Viana Avelar; Borges, Keyller Bastos
2018-10-01
A simple HPLC method was developed for the determination of abamectin (ABA), eprinomectin (EPR), and moxidectin (MOX). Pipette-tip molecularly imprinted polymer solid-phase extraction (PT-MIP-SPE) using poly(1-vinylimidazole-co-trimethylolpropane trimethacrylate) as a selective adsorbent material was studied in detail, including the washing solvent, type and volume of eluent, pH, quantity of adsorbent material and sample volume. The performance criteria for linearity, sensitivity, precision, accuracy, recovery, robustness and stability have been assessed and were within the recommended guidelines. The mean extraction recoveries/relative standard deviation for ABA 1b, EPR, ABA 1a and MOX were 98.77 ± 3.82%, 88.19 ± 2.57%, 110.54 ± 1.52% and 100.42 ± 0.59%, respectively. Finally, the results proved that PT-MIP-SPE coupled to HPLC-UV is an economical, simple and easy-to-perform technique, and presented a high potential for extraction of macrocyclic lactones in mineral water and grape and juice samples. Copyright © 2018 Elsevier Ltd. All rights reserved.
Xin, Guobin; Tan, Jiayi; Yao, Lijuan; Zhu, Yu; Jiang, Zhaolin; Song, Hui
2008-01-01
A method for the determination of three phenoxyalkanoic acid herbicides, 2,4-dichlorophenoxyacetic acid (2,4-D), 2-(2,4-dichlorophenoxy)-propanoic acid (2,4-DP), and 4-chloro-2-methylphenoxy-acetic acid (MCPA), in blood was developed. The blood sample was diluted with 0.1 mol/L hydrochloric acid, and extracted by solid-phase extraction using porous resin GDX401 as adsorbent and ethyl ether as eluent. The extract was esterified with dichloropropanol in the presence of sulfuric acid as catalyst. The derivatives were analysed by gas chromatography with electron-capture detection. The detection limits of 2,4-D, 2,4-DP and MCPA were 20, 8 and 40 ng/mL, respectively. In quantitative analysis, 2,4-dichlorophenylacetic acid was used as an internal standard. The linear relationships and recoveries were satisfactory. The derivatization of the three herbicides with methanol, ethanol, n-propanol, n-butanol, and trifluoroethanol were also studied, and the analytical methods of these derivatization were compared with that of dichloropropanol as esterifying agent. The method is sensitive enough for the examination of the poison samples in actual.
Zhang, Rui; Li, Na; Wang, Chuanliu; Bai, Yuping; Ren, Ruibing; Gao, Shiqian; Yu, Wenzhi; Zhao, Tianqi; Zhang, Hanqi
2011-10-17
The foaming property of ionic liquids (ILs) was found and the factors that can influence foamability of the ILs were investigated. Based on the property of the ILs, the foam floatation-solid phase extraction (FF-SPE) was developed. The IL-based FF-SPE was applied to the extraction and concentration of steroid hormones, including corticosterone, 17-β-estadiol, 17-α-estradiol, 19-nortestosterone, estrone, testosterone, 17-α-hydroxyprogesterone, medroxyprogesterone, chloromadinon 17-acetate, norethisterone acetate, medroxyprogesterone-17-acetate, progesterone, 17-β-estradiol 3-benzoate and testosteron 17-propionate in water samples and then the steroid hormones were determined by high-performance liquid chromatography. The extraction and concentration were performed synchronously in 10 min. Some experimental conditions were examined and optimized. The recoveries ranged from 50.6% to 95.2% for lake water sample and from 53.4% to 98.7% for rain water sample. The precision ranged from 2.43% to 7.43% for the lake water sample and 2.07-7.01% for rain water sample. Based on the foaming property of ILs, the application of foam floatation should be widened. Copyright © 2011 Elsevier B.V. All rights reserved.
Zhang, Ming; Tang, Fangliang; Yu, Yayun; Chen, Feng; Xu, Jianfen; Ye, Yonggen
2014-05-01
A high-throughput detection method has been developed for the determination of sixteen perfluorinated organic compounds (PFCs) in surface water by solid phase extraction-ultra performance liquid chromatography coupled with electrospray ionization tandem mass spectrometry (SPE-UPLC-ESI-MS/MS). The water samples were concentrated and purified through WAX solid phase extraction cartridges. The UPLC separation was performed on an ACQUITY UPLC BEH C18 column utilizing a gradient elution program of methanol (containing 2 mmol/L ammonium acetate) and water (containing 2 mmol/L ammonium acetate) as the mobile phases at a flow rate of 0.4 mL/min. The MS/MS detection was performed under negative electrospray ionization ( ESI ) in multiple reaction monitoring (MRM) mode. Good linearities were observed in the range of 0.5-100 gg/L or 1.0 - 100 microg/L with correlation coefficients from 0.998 7 to 0.999 9. The limits of detection (LODs) for the sixteen perfluorinated organic compounds were in the range of 0.06-0.46 ng/L. The recoveries ranged from 67.6% to 103% with the relative standard deviations between 2.94% and 12.0%. This method was characterized by high sensitivity and precision, extensive range and high speed, and can be applied for the analysis of PFC contaminants in surface water.
Lei, Meikang; Peng, Fang; Ding, Tao; Zhu, Zitong; Xu, Jiawen; Wu, Xiaoqin
2015-01-01
A method based on solid phase extraction and ultra performance liquid chromatography coupled with tandem mass spectrometry (SPE-UPLC-MS/MS) has been proposed for the determination of wilforine residue in honey. After the sample was dissolved with water, concentrated and purified by an HLB solid phase extraction cartridge, the UPLC separation was performed on a Hypersil GOLD C18 column (50 mm x 2.1 mm, 1.9 microm) utilizing a gradient elution program of methanol (containing 0.15% formic acid) and water as mobile phases at a flow rate of 0. 25 mL/min. The determination was carried out with electrospray ion source in the positive mode (ESI) and multiple reaction monitoring (MRM) mode. The mass concentration of wilforine in the range of 0.01-2 microg/L was linearly correlated with the peak area, and the correlation coefficients was greater than 0.998. The limit of quantification (S/N>10) for wilforine was 0.01 microg/kg. The recoveries were 76.1% to 96.2% in the spiked levels of 0.01, 0.05 and 0.5 microg/kg with the relative standard deviations (RSD, n=6) lower than 10%. The results indicate that the method is rapid, sensitive and accurate, and can be applied for the qualitative and quantitative analysis of wilforine in honey.
Zhang, Ming; Tang, Fangliang; Xu, Jianfen; Yu, Bo; Zhang, Wei; Yao, Jianliang; Hu, Minhua
2017-10-08
A high-throughput detection method has been developed for the determination of nine perfluorinated compound precursors (PFCPs) in atmospheric precipitation by solid phase extraction-ultra performance liquid chromatography coupled with electrospray ionization tandem mass spectrometry (SPE-UPLC-ESI-MS/MS). The atmospheric precipitation samples were concentrated and purified with HLB solid phase extraction cartridges. The UPLC separation was performed on an HSS T 3 column (100 mm×2.1 mm, 1.7 μm) utilizing a gradient elution program of methanol and water as the mobile phases at a flow rate of 0.2 mL/min. The MS/MS detection was performed under negative electrospray ionization (ESI - ) in multiple reaction monitoring (MRM) mode. Good linearity was observed in the range of 0.05-5.00 μg/L, 0.50-50.0 μg/L or 5.00-500 μg/L with correlation coefficients from 0.9921 to 0.9995. The limits of detection (LODs) for the nine perfluorinated compound precursors were in the ranges of 0.05-7.9 ng/L. The recoveries ranged from 76.0% to 106% with the relative standard deviations between 0.72% and 13.7%. This method is characterized by high sensitivity and precision, extensive analytical range and quick analytical rate, and can be applied for the analysis of perfluorinated compound precursors in atmospheric precipitation.
Medina, Giselle S; Reta, Mario
2016-11-01
A dispersive liquid-liquid microextraction method using a lighter-than-water phosphonium-based ionic liquid for the extraction of 16 polycyclic aromatic hydrocarbons from water samples has been developed. The extracted compounds were analyzed by liquid chromatography coupled to fluorescence/diode array detectors. The effects of several experimental parameters on the extraction efficiency, such as type and volume of ionic liquid and disperser solvent, type and concentration of salt in the aqueous phase and extraction time, were investigated and optimized. Three phosphonium-based ionic liquids were assayed, obtaining larger extraction efficiencies when trihexyl-(tetradecyl)phosphonium bromide was used. The optimized methodology requires a few microliters of a lighter-than-water phosphonium-based ionic liquid, which allows an easy separation of the extraction solvent phase. The obtained limits of detection were between 0.02 and 0.56 μg/L, enrichment factors between 109 and 228, recoveries between 60 and 108%, trueness between 0.4 and 9.9% and reproducibility values between 3 and 12% were obtained. These figures of merit combined with the simplicity, rapidity and low cost of the analytical methodology indicate that this is a viable and convenient alternative to the methods reported in the literature. The developed method was used to analyze polycyclic aromatic hydrocarbons in river water samples. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Wang, Yudan; Dai, Xinpeng; He, Xi; Chen, Lin; Hou, Xiaohong
2017-10-25
In this work, MIL-101(Cr)@GO (Graphite Oxide) was synthesized using a hydrothermal synthesis method and was applied as a dispersive micro-solid-phase extraction (D-μ-SPE) sorbent for the efficient concentration of four residual drugs (metronidazole, MNZ; tinidazole, TNZ; chloramphenicol, CAP; sulfamethoxazole, SMX). Meanwhile, the extraction process was optimized by combining it with microwave-assisted extraction. Factors affecting the D-μ-SPE efficiency, such as selection of sorbent materials, pH of the sample solution, salting-out effect, amount of used material, extraction time, desorption solvent and desorption time, were studied. Under the optimal extraction conditions, the linearity ranged from 10 to 1000ngkg -1 and 1-100ngkg -1 (r 2 ≥0.9928) for the target analytes. The limits of detection were between 0.08 and 1.02ngkg -1 , and the limits of quantitation were between 0.26 and 3.40ngkg -1 . Additionally, the developed method also exhibited good precision (RSD≤2.5%), repeatability (RSD≤4.3%), high recoveries (88.9%-102.3%) and low matrix effects (78.2%-95.1%). The proposed method proved to be an efficient and reliable approach for the determination of the analytes. Finally, we successfully detected the four drugs in chicken breast. Copyright © 2017 Elsevier B.V. All rights reserved.
Pizarro, C; Pérez-del-Notario, N; González-Sáiz, J M
2010-09-24
A simple, accurate and sensitive method based on headspace solid-phase microextraction (HS-SPME) coupled to gas chromatography-tandem mass spectrometry (GC-MS/MS) was developed for the analysis of 4-ethylguaiacol, 4-ethylphenol, 4-vinylguaiacol and 4-vinylphenol in beer. The effect of the presence of CO2 in the sample on the extraction of analytes was examined. The influence on extraction efficiency of different fibre coatings, of salt addition and stirring was also evaluated. Divinylbenzene/carboxen/polydimethylsiloxane was selected as extraction fibre and was used to evaluate the influence of exposure time, extraction temperature and sample volume/total volume ratio (Vs/Vt) by means of a central composite design (CCD). The optimal conditions identified were 80 degrees C for extraction temperature, 55 min for extraction time and 6 mL of beer (Vs/Vt 0.30). Under optimal conditions, the proposed method showed satisfactory linearity (correlation coefficients between 0.993 and 0.999), precision (between 6.3% and 9.7%) and detection limits (lower than those previously reported for volatile phenols in beers). The method was applied successfully to the analysis of beer samples. To our knowledge, this is the first time that a HS-SPME based method has been developed to determine simultaneously these four volatile phenols in beers. Copyright 2010 Elsevier B.V. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chen Hong
The {pi}{pi} S-wave phase shifts below 0.6 GeV are extracted out from the published data of the decay {psi}(2S){yields}{pi}{sup +}{pi}{sup -}J/{psi}. In fitting to the m{sub {pi}}{sub {pi}} distribution, several {pi}{pi} production mechanisms are modeled in the amplitude. The fit results show that the amplitude including the {pi}{pi} rescattering process with the minimal coupling g{sub 1}{epsilon}{sup '}{center_dot}{epsilon}* plus the direct nonresonant three-body decay process yields phase shifts consistent with those measured in scattering experiments and K{sub e4} decays. This result agrees with the expectation of the Watson theorem.
Siu, S O; Lam, Maggie P Y; Lau, Edward; Yeung, William S B; Cox, David M; Chu, Ivan K
2010-01-01
Although reverse-phase liquid chromatography (RP-LC) is a common technique for peptide separation in shotgun proteomics and glycoproteomics, it often provides unsatisfactory results for the analysis of glycopeptides and glycans. This bias against glycopeptides makes it difficult to study glycoproteins. By coupling mass spectrometry (MS) with a combination of RP-LC and normal-phase (NP)-LC as an integrated front-end separation system, we demonstrate that effective identification and characterization of both peptides and glycopeptides mixtures, and their constituent glycan structures, can be achieved from a single sample injection event.
Yu, Fangjun; Qian, Hao; Zhang, Jiayu; Sun, Jie; Ma, Zhiguo
2018-04-01
We aim to determine the chemical constituents of Yinchen extract and Yinchen herbs using high-performance liquid chromatography coupled with diode array detection and high-resolution mass spectrometry. The method was developed to analyze of eight organic acid components of Yinchen extract (including neochlorogenic acid, chlorogenic acid, cryptochlorogenic acid, caffeic acid, 1,3-dicaffeoylquinic acid, 3,4-dicaffeoylquinic acid, 3,5-dicaffeoylquinic acid and 4,5-dicaffeoylquinic acid). The separation was conducted using an Agilent TC-C18 column with acetonitrile - 0.2% formic acid solution as the mobile phases under gradient elution. The analytical method was fully validated in terms of linearity, sensitivity, precision, repeatability as well as recovery, and subsequently the method was performed for the quantitative assessment of Yinchen extracts and Yinchen herbs. In addition, the changes of selected markers were studied when Yinchen herbs decocting in water and isomerization occurred between the chlorogenic acids. The proposed method enables both qualitative and quantitative analyses and could be developed as a new tool for the quality evaluation of Yinchen extract and Yinchen herbs. The changes of selected markers in water decoction process could give us some novel idea when studying the link between substances and drug efficacy. Copyright © 2017. Published by Elsevier B.V.
Rodríguez-Sánchez, S; García-Sarrió, M J; Quintanilla-López, J E; Soria, A C; Sanz, M L
2015-12-04
A method by hydrophilic interaction liquid chromatography coupled to tandem mass spectrometry (HILIC-MS(2)) has been successfully developed for the simultaneous analysis of bioactive iminosugars and other low molecular weight carbohydrates in Aglaonema leaf extracts. Among other experimental chromatographic conditions, mobile phase eluents, additives and column temperature were evaluated in terms of retention time, resolution, peak width and symmetry provided for target carbohydrates. In general, narrow peaks (wh: 0.2-0.6min) with good symmetry (As: 0.9-1.3) and excellent resolution (Rs>1.8) were obtained for iminosugars using an acetonitrile:water gradient with 5mM ammonium acetate in both eluents at 55°C. Tandem mass spectra were used to confirm the presence of previously detected iminosugars in Aglaonema extracts and to tentatively identify for the first time others such as miglitol isomer, glycosyl-miglitol isomers and glycosyl-DMDP isomers. Concentration of total iminosugars varied from 1.35 to 2.84mgg(-1) in the extracts of the different Aglaonema samples analyzed. To the best of our knowledge, this is the first time that a HILIC-MS(2) method has been proposed for the simultaneous analysis of iminosugars and other low molecular weight carbohydrates of Aglaonema sp. extracts. Copyright © 2015 Elsevier B.V. All rights reserved.
Lin, Hsin-Hang; Sung, Yu-Hsiang; Huang, Shang-Da
2003-09-12
Solid-phase microextraction coupled with high-performance liquid chromatography was successfully applied to the analysis of nine phenylurea herbicides (metoxuron, monuron, chlorotoluron, isoproturon, monolinuron, metobromuron, buturon, linuron, and chlorbromuron). Polydimethylsiloxane-divinylbenzene (PDMS-DVB, 60 microm) and Carbowax-templated resin (CW-TPR, 50 microm) fibers were selected from four commercial fibers for further study because of their better extraction efficiencies. The parameters of the desorption procedure were studied and optimized. The effects of the properties of analytes and fiber coatings, carryover, duration and temperature of absorption, pH, organic solvent and ionic strength of samples were also investigated. External calibration with an aqueous standard can be used for the analysis of environmental samples (lake water) using either PDMS-DVB or CW-TPR fibers. Good precisions (1.0-5.9%) are achieved for this method, and the detection limits are at the level of 0.5-5.1 ng/ml.
Millán, S; Sampedro, M C; Unceta, N; Goicolea, M A; Rodríguez, E; Barrio, R J
2003-05-02
A solid-phase microextraction (SPME) method coupled to high-performance liquid chromatography with diode array detection (HPLC-DAD) for the analysis of six organochlorine fungicides (nuarimol, triadimenol, triadimefon, folpet, vinclozolin and penconazole) in wine was developed. For this purpose, polydimethylsiloxane-divinylbenzene-coated fibers were utilized and all factors affecting throughput, precision, and accuracy of the SPME method were investigated and optimized. These factors include: matrix influence, extraction and desorption time, percentage of ethanol, pH, salt effect and desorption mode. The performed analytical procedure showed detectability ranging from 4 to 27 microg l(-1) and precision from 2.4 to 14.2% (as intra-day relative standard deviation, RSD) and 4.7-25.7% (as inter-day RSD) depending on the fungicide. The results demonstrate the suitability of the SPME-HPLC-DAD method to analyze these organochlorine fungicides in red wine.
Yang, Xiu-Min; Wang, Ou; Wang, Ming-Zhao; Hu, Yan-Xue; Li, Wei-Ning; Wang, Zhi
2008-09-01
A method for the determination of metolcarb and diethofencarb in apples and apple juice is developed using solid-phase microextraction (SPME) coupled with high-performance liquid chromatography (HPLC). The experimental conditions of SPME, such as the kind of extraction fiber, extraction time, stirring rate, pH of the extracting solution, and desorption conditions are optimized. The SPME is performed on a 60 microm polydimethylsiloxane/divinylbenzene fiber for 40 min at room temperature with the solution being stirred at 1100 rpm. The extracted pesticides on the SPME fiber are desorbed in the mobile phase into SPME-HPLC interface for HPLC analysis. Separations are carried out on a Baseline C18 column (4.6 i.d. x 250 mm, 5.0 microm) with acetonitrile-water (55/45, v/v) as the mobile phase at a flow rate of 1.0 mL/min, and photodiode-array detection at 210 nm. For apple samples, the method is linear for both metolcarb and diethofencarb in the range of 0.05-1.0 mg/kg (r > 0.99), with a detection limit (S/N = 3 ) of 15 and 5 microg/kg, respectively. For apple juice, the method is linear for both metholcarb and diethofencarb over the range of 0.05-1.0 mg/L (r > 0.99) with the detection limit (S/N = 3 ) of 15 and 3 microg/L, respectively. Excellent recovery and reproducibility values are achieved. The proposed method is shown to be simple, sensitive, and organic solvent-free, and is suitable for the determination of the two pesticides in apples and apple juice.
Huang, Ke; Xu, Kailai; Zhu, Wei; Yang, Lu; Hou, Xiandeng; Zheng, Chengbin
2016-01-05
A low-cost, simple, and highly selective analytical method was developed for sensitive visual detection of selenium in human urine both outdoors and at home, by coupling hydride generation with headspace solid-phase extraction using quantum dots (QDs) immobilized on paper. The visible fluorescence from the CdTe QDs immobilized on paper was quenched by H2Se from hydride generation reaction and headspace solid-phase extraction. The potential mechanism was investigated by using X-ray diffraction (XRD) and X-ray photoelectron spectroscopy (XPS) as well as Density Functional Theory (DFT). Potential interferences from coexisting ions, particularly Ag(+), Cu(2+), and Zn(2+), were eliminated. The selectivity was significantly increased because the selenium hydride was effectively separated from sample matrices by hydride generation. Moreover, due to the high sampling efficiency of hydride generation and headspace solid phase extraction, the sensitivity and the limit of detection (LOD) were significantly improved compared to conventional methods. A LOD of 0.1 μg L(-1) and a relative standard deviation (RSD, n = 7) of 2.4% at a concentration of 20 μg L(-1) were obtained when using a commercial spectrofluorometer as the detector. Furthermore, a visual assay based on the proposed method was developed for the detection of Se, 5 μg L(-1) of selenium in urine can be discriminated from the blank solution with the naked eye. The proposed method was validated by analysis of certified reference materials and human urine samples with satisfactory results.
Florez, Diego Hernando Ângulo; Teixeira, Roseane Andrade; da Silva, Ricky Cássio Santos; Pires, Bruna Carneiro; Dutra, Flávia Viana Avelar; Borges, Keyller Bastos
2018-05-01
In this work, we developed a HPLC method for the multidetermination of avermectins (AVM) (abamectin-ABA 1b and ABA 1a, eprinomectin-EPR, and ivermectin-IVM) and milbemycins (moxidectin-MOX) in milk samples using polypyrrole (PPy) as adsorbent material in pipette-tip solid-phase extraction (PT-PPy-SPE). PPy was characterized by scanning electron microscopy, thermogravimetric analysis, Fourier transform infrared spectroscopy, and X-ray diffraction and the data agreed with the literature. The sample preparation included the clean-up of the milk by protein precipitation (PP) with acetonitrile and extraction of the analytes by PT-PPy-SPE. The chromatographic method was developed in reverse phase and isocratic mode with flow rate at 1.2 mL min -1 and ultraviolet detection at 250 nm. The mobile phase composition was acetonitrile:methanol:water (55:25:20, v/v/v). The studied parameters and the optimized conditions for the sample preparation were washing solvent (300 μL water), volume and type of eluent (500 μL methanol), volume and pH of sample (1 mL and pH 10), amount of adsorbent material (50 mg PPy), and without addition of salt (NaCl). The method was linear over the concentration range from 20 to 3000 ng mL -1 with coefficients of correlation (r) ≥ 0.99 for all analytes and recoveries around 100%. The method developed and validated was used for the analyses of real milk samples from cow treated with Ivomec ® (IVM 3.5%), in which were found 21.51 ± 2.94 ng mL -1 of IVM. Finally, the results proved that PT-PPy-SPE coupled to HPLC-UV was economical, simple, and easy-to-perform technique. Graphical abstract Pipette-tip solid phase extraction using polypirrole as adsorbent material for determination of avermectins and milbemycins in milk.
Muniraj, Sarangapani; Yan, Cheing-Tong; Shih, Hou-Kung; Ponnusamy, Vinoth Kumar; Jen, Jen-Fon
2012-11-19
A new simultaneous derivatization and extraction method for the preconcentration of ammonia using new one-step headspace dynamic in-syringe liquid-phase microextraction with in situ derivatization was developed for the trace determination of ammonium in aqueous samples by liquid chromatography with fluorescence detection (LC-FLD). The acceptor phase (as derivatization reagent) containing o-phthaldehyde and sodium sulfite was held within a syringe barrel and immersed in the headspace of sample container. The gaseous ammonia from the alkalized aqueous sample formed a stable isoindole derivative with the acceptor phase inside the syringe barrel through the reciprocated movements of plunger. After derivatization-cum-extraction, the acceptor phase was directly injected into LC-FLD for analysis. Parameters affecting the ammonia evolution and the extraction/derivatization efficiency such as sample matrix, pH, temperature, sampling time, and the composition of derivatization reagent, reaction temperature, and frequency of reciprocated plunger, were studied thoroughly. Results indicated that the maximum extraction efficiency was obtained by using 100μL derivatization reagent in a 1-mL gastight syringe under 8 reciprocated movements of plunger per min to extract ammonia evolved from a 20mL alkalized aqueous solution at 70°C (preheated 4min) with 380rpm stirring for 8min. The detection was linear in the concentration range of 0.625-10μM with the correlation coefficient of 0.9967 and detection limit of 0.33μM (5.6ng mL(-1)) based on SN(-1)=3. The method was applied successfully to determine ammonium in real water samples without any prior cleanup of the samples, and has been proved to be a simple, sensitive, efficient and cost-effective procedure for trace ammonium determination in aqueous samples. Copyright © 2012 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Yang, Z.; Juanes, R.
2015-12-01
The geomechanical processes associated with subsurface fluid injection/extraction is of central importance for many industrial operations related to energy and water resources. However, the mechanisms controlling the stability and slip motion of a preexisting geologic fault remain poorly understood and are critical for the assessment of seismic risk. In this work, we develop a coupled hydro-geomechanical model to investigate the effect of fluid injection induced pressure perturbation on the slip behavior of a sealing fault. The model couples single-phase flow in the pores and mechanics of the solid phase. Granular packs (see example in Fig. 1a) are numerically generated where the grains can be either bonded or not, depending on the degree of cementation. A pore network is extracted for each granular pack with pore body volumes and pore throat conductivities calculated rigorously based on geometry of the local pore space. The pore fluid pressure is solved via an explicit scheme, taking into account the effect of deformation of the solid matrix. The mechanics part of the model is solved using the discrete element method (DEM). We first test the validity of the model with regard to the classical one-dimensional consolidation problem where an analytical solution exists. We then demonstrate the ability of the coupled model to reproduce rock deformation behavior measured in triaxial laboratory tests under the influence of pore pressure. We proceed to study the fault stability in presence of a pressure discontinuity across the impermeable fault which is implemented as a plane with its intersected pore throats being deactivated and thus obstructing fluid flow (Fig. 1b, c). We focus on the onset of shear failure along preexisting faults. We discuss the fault stability criterion in light of the numerical results obtained from the DEM simulations coupled with pore fluid flow. The implication on how should faults be treated in a large-scale continuum model is also presented.
Breil, Cassandra; Abert Vian, Maryline; Zemb, Thomas; Kunz, Werner; Chemat, Farid
2017-03-27
Bligh and Dyer (B & D) or Folch procedures for the extraction and separation of lipids from microorganisms and biological tissues using chloroform/methanol/water have been used tens of thousands of times and are "gold standards" for the analysis of extracted lipids. Based on the Conductor-like Screening MOdel for realistic Solvatation (COSMO-RS), we select ethanol and ethyl acetate as being potentially suitable for the substitution of methanol and chloroform. We confirm this by performing solid-liquid extraction of yeast ( Yarrowia lipolytica IFP29 ) and subsequent liquid-liquid partition-the two steps of routine extraction. For this purpose, we consider similar points in the ternary phase diagrams of water/methanol/chloroform and water/ethanol/ethyl acetate, both in the monophasic mixtures and in the liquid-liquid miscibility gap. Based on high performance thin-layer chromatography (HPTLC) to obtain the distribution of lipids classes, and gas chromatography coupled with a flame ionisation detector (GC/FID) to obtain fatty acid profiles, this greener solvents pair is found to be almost as effective as the classic methanol-chloroform couple in terms of efficiency and selectivity of lipids and non-lipid material. Moreover, using these bio-sourced solvents as an alternative system is shown to be as effective as the classical system in terms of the yield of lipids extracted from microorganism tissues, independently of their apparent hydrophilicity.
Zou, Nan; Yuan, Chunhao; Liu, Shaowen; Han, Yongtao; Li, Yanjie; Zhang, Jialei; Xu, Xiang; Li, Xuesheng; Pan, Canping
2016-07-29
An analytical method based on stir bar sorptive extraction (SBSE) coupled with pulse glow discharge-ion mobility spectrometry (PGD-IMS) was developed for analysis of three triazine pesticide residues in water and soil samples. An injection port with sealing device and stir bars hold device were designed and constructed to directly position the SBSE fiber including the extracted samples into the heating device, making desorption and detection of analytes proceeded simultaneously. The extraction conditions such as SBSE solid phase material, extraction time, extraction temperature, pH value and salt concentration were optimized. Mixture of MWCNTs-COOH and PDMS were shown to be effective in enriching the triazines. The LODs and LOQs of three triazines were found to be 0.006-0.015μgkg(-1) and 0.02-0.05μgkg(-1), and the linear range was 0.05-10μgL(-1) with determination coefficients from 0.9987 to 0.9993. The SBSE-PGD-IMS method was environmentally friendly without organic solvent consumption in the entire experimental procedures, and it was demonstrated to be a commendable rapid analysis technique for analysis of triazine pesticide residues in environmental samples on site. The proposed method was applied for the analysis of real ground water, surface water and soil samples. Copyright © 2016 Elsevier B.V. All rights reserved.
Breil, Cassandra; Abert Vian, Maryline; Zemb, Thomas; Kunz, Werner; Chemat, Farid
2017-01-01
Bligh and Dyer (B & D) or Folch procedures for the extraction and separation of lipids from microorganisms and biological tissues using chloroform/methanol/water have been used tens of thousands of times and are “gold standards” for the analysis of extracted lipids. Based on the Conductor-like Screening MOdel for realistic Solvatation (COSMO-RS), we select ethanol and ethyl acetate as being potentially suitable for the substitution of methanol and chloroform. We confirm this by performing solid–liquid extraction of yeast (Yarrowia lipolytica IFP29) and subsequent liquid–liquid partition—the two steps of routine extraction. For this purpose, we consider similar points in the ternary phase diagrams of water/methanol/chloroform and water/ethanol/ethyl acetate, both in the monophasic mixtures and in the liquid–liquid miscibility gap. Based on high performance thin-layer chromatography (HPTLC) to obtain the distribution of lipids classes, and gas chromatography coupled with a flame ionisation detector (GC/FID) to obtain fatty acid profiles, this greener solvents pair is found to be almost as effective as the classic methanol–chloroform couple in terms of efficiency and selectivity of lipids and non-lipid material. Moreover, using these bio-sourced solvents as an alternative system is shown to be as effective as the classical system in terms of the yield of lipids extracted from microorganism tissues, independently of their apparent hydrophilicity. PMID:28346372
Shao, P; Zhang, J F; Chen, X X; Sun, P L
2015-08-01
An efficient method for the rapid extraction, separation and purification of chlorogenic acid (CGA) from by-products of Eucommia Ulmoides Oliver (E. ulmoides) by microwave-assisted extraction (MAE) coupled with high-speed counter-current chromatography (HSCCC) was developed. The optimal MAE parameters were evaluated by response surface methodology (RSM), and they were extraction time of 12 min, microwave power of 420 W, ethanol concentration of 75 %, solvent/sample ratio of 30:1 (mL/g), yield of CGA reached 3.59 %. The crude extract was separated and purified directly by HSCCC using ethyl acetate-butyl alcohol-water (3:1:4, v/v) as the two-phase solvent system. The 14.5 mg of CGA with the purity of 98.7 % was obtained in one-step separation from 400 mg of crude extract. The chemical structure of CGA was verified with IR, ESI-MS analysis. Meanwhile, the purified CGA extract was evaluated by MTT assay and results indicate that CGA extract exhibited potential anti-tumor activity for AGS gastric cancer cell.
Klejdus, Bořivoj; Plaza, Merichel; Šnóblová, Marie; Lojková, Lea
2017-02-20
The extraction of phenolic compounds from 4 different sea algae samples, three brown algae (Cystoseira abies-marina, C. abies-marina grinded under cryogenic conditions with liquid nitrogen, Undaria pinnatifida and Sargassum muticum) and one red algae (Chondrus crispus) via solid phase extraction using micro-elution solid-phase extraction (μ-SPE) plate method was studied. Prior to μ-SPE, 50mg of algae with 80% methanol mixture was extracted in hyphenated series by various extraction techniques, such as pressurized liquid extraction and Ika Ultra-Turrax ® Tube Drive, in combination with ultrasound assisted extraction. The μ-SPE plate technique reduced the time of sample pre-treatment thanks to higher sensitivity and pre-concentration effect. Selected groups of benzoic acid derivatives (p-hydroxybenzoic, protocatechuic, gallic, vanillic, and syringic acids), hydroxybenzaldehydes (4-hydroxybenzaldehyde, and 3,4-dihydroxybenzaldehyde), and cinnamic acid derivatives (p-coumaric, caffeic, ferulic, sinapic, and chlorogenic acids) were determined using rapid resolution liquid chromatography coupled to mass spectrometry detection with negative ion electrospray ionization (RRLC-ESI-MS) using multiple reactions monitoring. LOQs of measured samples varied in the range 0.23-1.68ng/mL and LODs in the range 0.07-0.52ng/mL. The applied method allowed a simultaneous determination of phenolics (i.e. free, esters soluble in methanol, glycosides, and esters insoluble in methanol) in less than 5min (including alkaline or acidic hydrolysis of raw extracts) from sea algae extracts. Copyright © 2016 Elsevier B.V. All rights reserved.
Global Phase Diagram of a Three-Dimensional Dirty Topological Superconductor
NASA Astrophysics Data System (ADS)
Roy, Bitan; Alavirad, Yahya; Sau, Jay D.
2017-06-01
We investigate the phase diagram of a three-dimensional, time-reversal symmetric topological superconductor in the presence of charge impurities and random s -wave pairing. Combining complimentary field theoretic and numerical methods, we show that the quantum phase transition between two topologically distinct paired states (or thermal insulators), described by thermal Dirac semimetal, remains unaffected in the presence of sufficiently weak generic randomness. At stronger disorder, however, these two phases are separated by an intervening thermal metallic phase of diffusive Majorana fermions. We show that across the insulator-insulator and metal-insulator transitions, normalized thermal conductance displays single parameter scaling, allowing us to numerically extract the critical exponents across them. The pertinence of our study in strong spin-orbit coupled, three-dimensional doped narrow gap semiconductors, such as CuxBi2Se3 , is discussed.
Cagliero, Cecilia; Ho, Tien D; Zhang, Cheng; Bicchi, Carlo; Anderson, Jared L
2016-06-03
This study describes a simple and rapid sampling method employing a polymeric ionic liquid (PIL) sorbent coating in direct immersion solid-phase microextraction (SPME) for the trace-level analysis of acrylamide in brewed coffee and coffee powder. The crosslinked PIL sorbent coating demonstrated superior sensitivity in the extraction of acrylamide compared to all commercially available SPME coatings. A spin coating method was developed to evenly distribute the PIL coating on the SPME support and reproducibly produce fibers with a large film thickness. Ninhydrin was employed as a quenching reagent during extraction to inhibit the production of interfering acrylamide. The PIL fiber produced a limit of quantitation for acrylamide of 10μgL(-1) and achieved comparable results to the ISO method in the analysis of six coffee powder samples. Copyright © 2016 Elsevier B.V. All rights reserved.
Uranium decay daughters from isolated mines: Accumulation and sources.
Cuvier, A; Panza, F; Pourcelot, L; Foissard, B; Cagnat, X; Prunier, J; van Beek, P; Souhaut, M; Le Roux, G
2015-11-01
This study combines in situ gamma spectrometry performed at different scales, in order to accurately locate the contamination pools, to identify the concerned radionuclides and to determine the distribution of the contaminants from soil to bearing phase scale. The potential mobility of several radionuclides is also evaluated using sequential extraction. Using this procedure, an accumulation area located downstream of a former French uranium mine and concentrating a significant fraction of radioactivity is highlighted. We report disequilibria in the U-decay chains, which are likely related to the processes implemented on the mining area. Coupling of mineralogical analyzes with sequential extraction allow us to highlight the presence of barium sulfate, which may be the carrier of the Ra-226 activities found in the residual phase (Ba(Ra)SO4). In contrast, uranium is essentially in the reducible fraction and potentially trapped in clay-iron coatings located on the surface of minerals. Copyright © 2015 Elsevier Ltd. All rights reserved.
Sergi, Manuel; Compagnone, Dario; Curini, Roberta; D'Ascenzo, Giuseppe; Del Carlo, Michele; Napoletano, Sabino; Risoluti, Roberta
2010-08-24
A confirmatory method for the determination of illicit drugs based on micro-solid phase extraction with modified tips, made of a functionalized fiberglass with apolar chains of octadecylsilane into monolithic structure, has been developed in this study. Drugs belonging to different chemical classes, such as amphetamine, methamphetamine, methylenedioxyamphetamine, methylenedioxyethylamphetamine, methylenedioxymethylamphetamine, cocaine, benzoylecgonine, ketamine, mescaline, phencyclidine and psilocybine were analyzed. The quantitation was performed by liquid chromatography-tandem mass spectrometry and the analytes were detected in positive ionization by means of an electrospray source. The limits of quantification ranged between 0.3 ng mL(-1) for cocaine and 4.9 ng mL(-1) for psilocybine, with coefficients of determination (r(2)) >0.99 for all the analytes as recommended in the guidelines of Society of Forensic Toxicologists-American Association Forensic Sciences. 2010 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Rimskaya-Korsakova, M. N.; Berezhnaya, E. D.; Dubinin, A. V.
2017-07-01
An analytical technique is proposed to determine ultratrace concentrations of Mo, V, and W found in seawater using mass spectrometry with inductively coupled plasma (ICP MS) after preliminary concentration by solid-phase extraction of metal complexes with 8-hydroxyquinoline (8-HQ) on C18 octadecyl silica. The technique utilizes 150 mL of a water sample. A preconcentration factor 50 is obtained. The detection limits are 0.25 nmol/kg, 0.041 nmol/kg, and 5 pmol/kg for Mo, V, and W, respectively. Dissolved Mo, V, and Wconcentrations in surface seawater from Atlantic Ocean transect were determined. The concentrations ranges along the transect were: 91-108 nmol/kg for Mo, 28-35 nmol/kg for V, and 55-75 pmol/kg for W. The Mo/W ratio varied from 1300 to 1800.
Sterckx, Femke L; Saison, Daan; Delvaux, Freddy R
2010-08-31
Monophenols are widely spread compounds contributing to the flavour of many foods and beverages. They are most likely present in beer, but so far, little is known about their influence on beer flavour. To quantify these monophenols in beer, we optimised a headspace solid-phase microextraction method coupled to gas chromatography-mass spectrometry. To improve their isolation from the beer matrix and their chromatographic properties, the monophenols were acetylated using acetic anhydride and KHCO(3) as derivatising agent and base catalyst, respectively. Derivatisation conditions were optimised with attention for the pH of the reaction medium. Additionally, different parameters affecting extraction efficiency were optimised, including fibre coating, extraction time and temperature and salt addition. Afterwards, we calibrated and validated the method successfully and applied it for the analysis of monophenols in beer samples. 2010 Elsevier B.V. All rights reserved.
Zhang, Liyuan; Wang, Changyuan; Li, Zuotong; Zhao, Changjiang; Zhang, Hanqi; Zhang, Dongjie
2018-04-15
Ionic liquid-based matrix solid phase dispersion-solvent flotation coupled with high performance liquid chromatography was developed for the determination of the acetanilide herbicides, including metazachlor, propanil, alachlor, propisochlor, pretilachlor, and butachlor in rice samples. Some experimental parameters, including the type of dispersant, the mass ratio of dispersant to sample, pH of sample solution, the type of extraction solvent, the type of ionic liquid, flotation time, and flow rate of N 2 were optimized. The average recoveries of the acetanilide herbicides at spiked concentrations of 50, 125, and 250 µg/kg ranged from 89.4% to 108.7%, and relative standard deviations were equal to or lower than 7.1%, the limits of quantification were in the range of 38.0 to 84.7 µg/kg. Copyright © 2017 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Xia, Qinghai; Yang, Yaling; Liu, Mousheng
2012-10-01
An aluminium sensitized spectrofluorimetric method coupled with salting-out assisted liquid-liquid ultrasonic extraction for the determination of four widely used fluoroquinolones (FQs) namely norfloxacin (NOR), ofloxacin (OFL), ciprofloxacin (CIP) and gatifloxacin (GAT) in bovine raw milk was described. The analytical procedure involves the fluorescence sensitization of aluminium (Al3+) by complexation with FQs, salting-out assisted liquid-liquid ultrasonic extraction (SALLUE), followed by spectrofluorometry. The influence of several parameters on the extraction (the salt species, the amount of salt, pH, temperature and phase volume ratio) was investigated. Under optimized experimental conditions, the detection limits of the method in milk varied from 0.009 μg/mL for NOR to 0.016 μg/mL for GAT (signal-to-noise ratio (S/N) = 3). The relative standard deviations (RSD) values were found to be relatively low (0.54-2.48% for four compounds). The calibration graph was linear from 0.015 to 2.25 μg/mL with coefficient of determinations not less than 0.9974. The methodology developed was applied to the determination of FQs in bovine raw milk samples. The main advantage of this method is simple, accurate and green. The method showed promising applications for analyzing polar analytes especially polar drugs in various sample matrices.
NASA Astrophysics Data System (ADS)
Liu, Yang; Wang, Jiang; Cai, Lihui; Chen, Yingyuan; Qin, Yingmei
2018-03-01
As a pattern of cross-frequency coupling (CFC), phase-amplitude coupling (PAC) depicts the interaction between the phase and amplitude of distinct frequency bands from the same signal, and has been proved to be closely related to the brain’s cognitive and memory activities. This work utilized PAC and support vector machine (SVM) classifier to identify the epileptic seizures from electroencephalogram (EEG) data. The entropy-based modulation index (MI) matrixes are used to express the strength of PAC, from which we extracted features as the input for classifier. Based on the Bonn database, which contains five datasets of EEG segments obtained from healthy volunteers and epileptic subjects, a 100% classification accuracy is achieved for identifying seizure ictal from healthy data, and an accuracy of 97.67% is reached in the classification of ictal EEG signals from inter-ictal EEGs. Based on the CHB-MIT database which is a group of continuously recorded epileptic EEGs by scalp electrodes, a 97.50% classification accuracy is obtained and a raising sign of MI value is found at 6s before seizure onset. The classification performance in this work is effective, and PAC can be considered as a useful tool for detecting and predicting the epileptic seizures and providing reference for clinical diagnosis.
Guan, Wenna; Zhu, Tao; Wang, Yuejie; Zhang, Zhongyi; Jin, Zhao; Wang, Cong; Bai, Fali
2016-09-01
Hydrocarbons are widespread in cyanobacteria, and the biochemical synthetic pathways were recently identified. Intracellular fatty alka(e)nes of cyanobacteria have been detected by liquid-liquid extraction (LLE) coupled to gas chromatography-mass spectrometry (GC/MS). However, whether fatty alka(e)nes can be released to cyanobacterial culture media remains to be clarified. This work develops a sensitive method for analyzing the trace level of extracellular hydrocarbons in cyanobacterial culture media by head space solid-phase microextraction (HS-SPME) coupled to GC/MS. Headspace (HS) extraction mode using polydimethylsiloxane fiber to extract for 30min at 50°C was employed as the optimal extraction conditions. Five cyanobacterial fatty alka(e)nes analogs including pentadecene (C15:1), pentadecane (C15:0), heptadecene (C17:1), heptadecane (C17:0), nonadecane (C19:0) were analyzed, and the data obtained from HS-SPME-GC/MS method were quantified using internal standard peak area comparisons. Limits of detection (LOD), limits of quantitation (LOQ), linear dynamic range, precisions (RSD) and recovery for the analysis of extracellular fatty alka(e)nes of cyanobacteria by HS-SPME-GC/MS were evaluated. The LODs limits of detection (S/N = 3) varied from 10 to 21 ng L-1. The correlation coefficients (r) of the calibration curves ranged from 0.9873 to 0.9977 with a linearity from 0.1 to 50 μg L-1. The RSD values were ranging from 7.8 to 14.0% and from 4.0 to 8.8% at 1.0 μg L-1 and 10.0 μg L-1 standard solutions, respectively. Comparative analysis of extracellular fatty alka(e)nes in the culture media of model cyanobacteria Synechocystis sp. PCC 6803 demonstrated that sensitivity of HS-SPME-GC/MS method was significantly higher than LLE method. Finally, we found that heptadecane can be released into the culture media of Synechocystis sp. PCC 6803 at the later growth period. Copyright © 2016 Elsevier B.V. All rights reserved.
Coupled π π , K K ¯ scattering in P -wave and the ρ resonance from lattice QCD
Wilson, David J.; Briceño, Raúl A.; Dudek, Jozef J.; ...
2015-11-02
In this study, we determine elastic and coupled-channel amplitudes for isospin-1 meson-meson scattering inmore » $P$-wave, by calculating correlation functions using lattice QCD with light quark masses such that $$m_\\pi = 236$$ MeV in a cubic volume of $$\\sim (4 \\,\\mathrm{fm})^3$$. Variational analyses of large matrices of correlation functions computed using operator constructions resembling $$\\pi\\pi$$, $$K\\overline{K}$$ and $$q\\bar{q}$$, in several moving frames and several lattice irreducible representations, leads to discrete energy spectra from which scattering amplitudes are extracted. In the elastic $$\\pi\\pi$$ scattering region we obtain a detailed energy-dependence for the phase-shift, corresponding to a $$\\rho$$ resonance, and we extend the analysis into the coupled-channel $$K\\overline{K}$$ region for the first time, finding a small coupling between the channels.« less
Repeating coupled earthquakes at Shishaldin Volcano, Alaska
Caplan-Auerbach, J.; Petersen, T.
2005-01-01
Since it last erupted in 1999, Shishaldin Volcano, Aleutian Islands, Alaska, has produced hundreds to thousands of long-period (1-2 Hz; LP) earthquakes every day with no other sign of volcanic unrest. In 2002, the earthquakes also exhibited a short-period (4-7 Hz; SP) signal occurring between 3 and 15 s before the LP phase. Although the SP phase contains higher frequencies than the LP phase, its spectral content is still well below that expected of brittle failure events. The SP phase was never observed without the LP phase, although LP events continued to occur in the absence of the precursory signal. The two-phased events are termed "coupled events", reflecting a triggered relationship between two discrete event types. Both phases are highly repetitive in time series, suggestive of stable, non-destructive sources. Waveform cross-correlation and spectral coherence are used to extract waveforms from the continuous record and determine precise P-wave arrivals for the SP phase. Although depths are poorly constrained, the SP phase is believed to lie at shallow (<4 km) depths just west of Shishaldin's summit. The variable timing between the SP and LP arrivals indicates that the trigger mechanism between the phases itself moves at variable speeds. A model is proposed in which the SP phase results from fluid moving within the conduit, possibly around an obstruction and the LP phase results from the coalescence of a shallow gas bubble. The variable timing is attributed to changes in gas content within the conduit. The destruction of the conduit obstacle on November 21, 2002 resulted in the abrupt disappearance of the SP phase.
Christou, Chrysoula K; Anthemidis, Aristidis N
2009-04-15
A novel flow injection (FI) on-line displacement solid phase extraction preconcentration and/or separation method coupled with FAAS in order to minimize interference from other metals was developed for trace silver determination. The proposed method involved the on-line formation and subsequently pre-sorption of lead diethyldithiocarbamate (Pb-DDTC) into a column packed with PTFE-turnings. The preconcentration and/or separation of the Ag(I) took place through a displacement reaction between Ag(I) and Pb(II) of the pre-sorbed Pb-DDTC. Finally, the retained analyte was eluted with isobutyl methyl ketone (IBMK) and delivered directly to nebulizer for measuring. Interference from co-existing ions with lower DDTC complex stability in comparison with Pb-DDTC, was eliminated without need for any masking reagent. With 120 s of preconcentration time at a sample flow rate of 7.6 mL min(-1), an enhancement factor of 110 and a detection limit (3s) of 0.2 microg L(-1) were obtained. The precision (RSD, n=10) was 3.1% at the 10 mug L(-1) level. The developed method was successfully applied to trace silver determination in a variety of environmental water samples and certified reference material.
Zhang, Ying; Li, Yan; Zhu, Xiao-Juan; Li, Min; Chen, Hao-Yu; Lv, Xiao-Ling; Zhang, Jian
2017-07-01
A reliable and accurate method for the determination of seven biogenic amines (BAs) was developed and validated with Chinese rice wine samples. The BAs were derivatised with dansyl chloride, cleaned up using solid-phase extraction (SPE) and separated by high-performance liquid chromatography (HPLC) coupled with ultraviolet (UV) detection. The optimised derivatisation reaction, conducted at pH 9.6 and 60°C for 30 min, ensured baseline separation and peak symmetry for each BA. SPE clean-up using Oasis MCX cartridges yielded good recovery rates for all BAs and effectively reduced matrix effects. The developed method shows good linearity with determination coefficients of more than 0.9989 over a concentration range of 0.1-100 mg l -1 . The limits of detection (LODs) for the investigated BAs ranged from 2.07 to 5.56 µg l -1 . The intra- and inter-day relative standard deviations (RSDs) ranged from 0.86% to 3.81% and from 2.13% to 3.82%, respectively. Spiking experiments showed that the overall recovery rates ranged from 85% to 113%. Thus, the proposed method was demonstrated as being suitable for simultaneous detection, with accurate and precise quantification, of BAs in Chinese rice wine.
Brächer, T.; Heussner, F.; Pirro, P.; Meyer, T.; Fischer, T.; Geilen, M.; Heinz, B.; Lägel, B.; Serga, A. A.; Hillebrands, B.
2016-01-01
Magnonic spin currents in the form of spin waves and their quanta, magnons, are a promising candidate for a new generation of wave-based logic devices beyond CMOS, where information is encoded in the phase of travelling spin-wave packets. The direct readout of this phase on a chip is of vital importance to couple magnonic circuits to conventional CMOS electronics. Here, we present the conversion of the spin-wave phase into a spin-wave intensity by local non-adiabatic parallel pumping in a microstructure. This conversion takes place within the spin-wave system itself and the resulting spin-wave intensity can be conveniently transformed into a DC voltage. We also demonstrate how the phase-to-intensity conversion can be used to extract the majority information from an all-magnonic majority gate. This conversion method promises a convenient readout of the magnon phase in future magnon-based devices. PMID:27905539
He, Huan; Yuan, Danhua; Gao, Zhanqi; Xiao, Deli; He, Hua; Dai, Hao; Peng, Jun; Li, Nan
2014-01-10
A novel magnetic solid-phase extraction (MSPE) method based on mixed hemimicelles of room temperature ionic liquids (RTILs) coated Fe3O4/SiO2 nanoparticles (NPs) was developed for simultaneous extraction of trace amounts of flavonoids in bio-matrix samples. A comparative study on the use of RTILs (C16mimBr) and CTAB-coated Fe3O4/SiO2 NPs as sorbents was presented. Owing to bigger adsorption amounts for analytes, RTILs-coated Fe3O4/SiO2 NPs was selected as MSPE materials and three analytes luteolin, quercetin and kaempferol can be quantitatively extracted and simultaneously determined coupled with high performance liquid chromatography (HPLC) in urine samples. No interferences were caused by proteins or endogenous compounds. Good linearity (R(2)>0.9993) for all calibration curves was obtained, and the limits of detection (LOD) for luteolin, quercetin and kaempferol were 0.10 ng/mL, 0.50 ng/mL and 0.20 ng/mL in urine samples, respectively. Satisfactory recoveries (93.5-97.6%, 90.1-95.4% and 93.3-96.6% for luteolin, quercetin and kaempferol) in biological matrices were achieved. It was notable that while using a small amount of Fe3O4/SiO2 NPs (4.0 mg) and C16mimBr (1.0 mg), satisfactory preconcentration factors and extraction recoveries for the three flavonoids were obtained. To the best of our knowledge, this is the first time a mixed hemimicelles MSPE method based on RTILs and Fe3O4/SiO2 NPs magnetic separation has ever been used for pretreatment of complex biological samples. Copyright © 2013 Elsevier B.V. All rights reserved.
Time-varying coupling functions: Dynamical inference and cause of synchronization transitions
NASA Astrophysics Data System (ADS)
Stankovski, Tomislav
2017-02-01
Interactions in nature can be described by their coupling strength, direction of coupling, and coupling function. The coupling strength and directionality are relatively well understood and studied, at least for two interacting systems; however, there can be a complexity in the interactions uniquely dependent on the coupling functions. Such a special case is studied here: synchronization transition occurs only due to the time variability of the coupling functions, while the net coupling strength is constant throughout the observation time. To motivate the investigation, an example is used to present an analysis of cross-frequency coupling functions between delta and alpha brain waves extracted from the electroencephalography recording of a healthy human subject in a free-running resting state. The results indicate that time-varying coupling functions are a reality for biological interactions. A model of phase oscillators is used to demonstrate and detect the synchronization transition caused by the varying coupling functions during an invariant coupling strength. The ability to detect this phenomenon is discussed with the method of dynamical Bayesian inference, which was able to infer the time-varying coupling functions. The form of the coupling function acts as an additional dimension for the interactions, and it should be taken into account when detecting biological or other interactions from data.
Mirnaghi, Fatemeh S; Pawliszyn, Janusz
2012-10-26
This work presents the development and evaluation of biocompatible polyacrylonitrile-polystyrene-divinylbenzene (PAN-PS-DVB) and polyacrylonitrile-phenylboronic acid (PAN-PBA) coatings for automated 96-blades (thin-film) solid phase microextraction (SPME) system, using high performance liquid chromatography (HPLC) coupled with tandem mass spectrometry (MS/MS). The SPME condition was optimized for 60 min equilibrium extraction and 40 min desorption for PAN-PS-DVB, and 120 min equilibrium extraction and 60 min desorption for PAN-PBA for parallel sample preparation of up to 96 samples. The thin film geometry of the SPME blades provided good extraction efficiency due to the larger surface area of the coating, and simultaneous sample preparation provided fast and accurate analysis. The PAN-PS-DVB and PAN-PBA 96-blade SPME coatings were evaluated for extraction of analytes in a wide range of polarity (log P=2.8 to -3.7), and they demonstrated efficient extraction recovery (3.5-98.9% for PAN-PS-DVB and 4.0-74.1% for PAN-PBA) for both polar and non-polar groups of compounds. Reusability, reproducibility, and reliability of the system were evaluated. The results demonstrated that both coatings presented chemical and mechanical stability and long-lasting extraction efficiency for more than 100 usages in phosphate-buffered saline (PBS) and human plasma. Copyright © 2012 Elsevier B.V. All rights reserved.
Duan, Yan-Ping; Dai, Chao-Meng; Zhang, Ya-Lei; Ling-Chen
2013-01-03
A novel multi-templates molecularly imprinted polymer (MIP), using acidic pharmaceuticals mixture (ibuprofen (IBP), naproxen (NPX), ketoprofen (KEP), diclofenac (DFC), and clofibric acid (CA)) as the template, was prepared as solid-phase extraction (SPE) material for the quantitative enrichment of acidic pharmaceuticals in environmental samples and off-line coupled with liquid chromatography-mass spectrometry (LC/MS/MS). Washing solvent was optimized in terms of kind and volume for removing the matrix constituents nonspecifically adsorbed on the MIP. When 1L of water sample spiked at 1μg/L was loaded onto the cartridge, the binding capacity of the MIP cartridge were 48.7μg/g for KEP, 60.7μg/g for NPX, 52μg/g for CA, 61.3μg/g for DFC and 60.7μg/g for IBP, respectively, which are higher than those of the commercial single template MIP in organic medium (e.g. toluene) reported in the literature. Recoveries of the five acidic pharmaceuticals extracted from 1L of real water samples such as lake water and wastewater spiked at 1μg/L were more than 95%. The recoveries of acidic pharmaceuticals extracted from 10-g sediment sample spiked at the 10ng/g level were in the range of 77.4-90.6%. To demonstrate the potential of the MIP obtained, a comparison with commercial C18 SPE cartridge was performed. Molecularly imprinted solid-phase extraction (MISPE) cartridge showed higher recoveries than commercial C18 SPE cartridge for acidic pharmaceuticals. These results showed the suitability of the MISPE method for the selective extraction of a group of structurally related compounds such as acidic pharmaceuticals. Copyright © 2012 Elsevier B.V. All rights reserved.
Rico-Yuste, A; Walravens, J; Urraca, J L; Abou-Hany, R A G; Descalzo, A B; Orellana, G; Rychlik, M; De Saeger, S; Moreno-Bondi, M C
2018-03-15
Molecularly imprinted porous polymer microspheres selective to Alternaria mycotoxins, alternariol (AOH) and alternariol monomethyl ether (AME), were synthesized and applied to the extraction of both mycotoxins in food samples. The polymer was prepared using 4-vinylpiridine (VIPY) and methacrylamide (MAM) as functional monomers, ethylene glycol dimethacrylate (EDMA) as cross-linker and 3,8,9-trihydroxy-6H-dibenzo[b,d]pyran-6-one (S2) as AOH surrogate template. A molecularly imprinted solid phase extraction (MISPE) method has been optimized for the selective isolation of the mycotoxins from aqueous samples coupled to HPLC with fluorescence (λ ex =258nm; λ em =440nm) or MS/MS analysis. The MISPE method was validated by UPLC-MS/MS for the determination of AOH and AME in tomato juice and sesame oil based on the European Commission Decision 2002/657/EC. Method performance was satisfactory with recoveries from 92.5% to 106.2% and limits of quantification within the 1.1-2.8µgkg -1 range in both samples. Copyright © 2017 Elsevier Ltd. All rights reserved.
Lian, Ziru; Wang, Jiangtao
2012-12-01
In this paper, a highly selective sample cleanup procedure combining molecular imprinting technique (MIT) and solid-phase extraction (SPE) was developed for the isolation of malachite green in seawater and seafood samples. The molecularly imprinted polymer (MIP) was prepared using malachite green as the template molecule, methacrylic acid as the functional monomer and ethylene glycol dimethacrylate as the cross-linking monomer. The imprinted polymer and non-imprinted polymer were characterized by scanning electron microscope and static adsorption experiments. The MIP showed a high adsorption capacity and was used as selective sorbent for the SPE of malachite green. An off-line molecularly imprinted solid-phase extraction (MISPE) method followed by high-performance liquid chromatography with diodearray detection for the analysis of malachite green in seawater and seafood samples was also established. Finally, five samples were determined. The results showed that malachite green concentration in one seawater sample was at 1.30 μg L⁻¹ and the RSD (n=3) was 4.15%. Crown Copyright © 2012. Published by Elsevier Ltd. All rights reserved.
Zhou, Qingxiang; Fang, Zhi; Liao, Xiangkun
2015-07-01
We describe a highly sensitive micro-solid-phase extraction method for the pre-concentration of six phthalate esters utilizing a TiO2 nanotube array coupled to high-performance liquid chromatography with a variable-wavelength ultraviolet visible detector. The selected phthalate esters included dimethyl phthalate, diethyl phthalate, dibutyl phthalate, butyl benzyl phthalate, bis(2-ethylhexyl)phthalate and dioctyl phthalate. The factors that would affect the enrichment, such as desorption solvent, sample pH, salting-out effect, extraction time and desorption time, were optimized. Under the optimum conditions, the linear range of the proposed method was 0.3-200 μg/L. The limits of detection were 0.04-0.2 μg/L (S/N = 3). The proposed method was successfully applied to the determination of six phthalate esters in water samples and satisfied spiked recoveries were achieved. These results indicated that the proposed method was appropriate for the determination of trace phthalate esters in environmental water samples. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Makkliang, Fonthip; Kanatharana, Proespichaya; Thavarungkul, Panote; Thammakhet, Chongdee
2015-01-01
A novel, simple and low cost magnetic multi-walled carbon nanotubes-poly (vinyl alcohol) cryogel-micro-solid phase extraction (magnetic-MWCNTs-PVA cryogel-μ-SPE) sorbent was synthesized by incorporating magnetic particles and MWCNTs into a PVA cryogel. The magnetic-MWCNTs-PVA cryogel-μ-SPE sorbent developed, with a large surface area and macro-porous structure, provided good sorbent-to-sorbent reproducibility (%RSD<8) and each sorbent could be used up to 30 times (%RSD<6). This sorbent was applied for the extraction of dibutyl phthalate (DBP) and di-2-(ethylhexyl) phthalate (DEHP) in packaged food prior to analysis by gas chromatograph coupled with flame ionisation detector (GC-FID). The concentration of DBP and DEHP in hot-water samples from plastic bags were found in the range 0.04-0.15 μg mL(-1) and 0.03-0.20 μg mL(-1), respectively, but only DEHP was found in clear chicken soup samples in the range 0.02-0.07 μg mL(-1). Copyright © 2014 Elsevier Ltd. All rights reserved.
Liu, Na; Shi, Yue-e; Li, Mengyan; Zhang, Ting-di; Gao, Song
2015-10-01
A simple and selective high-performance liquid chromatography method coupled with fluorescence detection was developed for the simultaneous measurement of trace levels of four estrogens (estrone, estradiol, estriol and 17α-ethynyl estradiol) in environmental matrices. For feces samples, solid-liquid extraction was applied with a 1:1 v/v mixture of acetonitrile and ethyl acetate as the extraction solvent. For liquid samples (e.g., leachate and groundwater), hydrophobic/lipophilic balanced automated solid-phase extraction disks were selected due to their high recoveries compared to conventional C18 disks. Chromatographic separations were performed on a reversed-phase C18 column gradient-eluted with a 45:55 v/v mixture of acetonitrile and water. The detection limits were down to 1.1 × 10(-2) (estrone), 4.11 × 10(-4) (estradiol), 5.2 × 10(-3) (estriol) and 7.18 × 10(-3) μg/L (17α-ethynyl estradiol) at excitation/emission wavelengths of 288/310 nm, with recoveries in the range of 96.9 ± 3.2-105.4 ± 3.2% (n = 3). The method was successfully applied to determine estrogens in feces and water samples collected at livestock farms and a major river in Northeast China. We observed relatively high abundance and widespread distribution of all four estrogens in our sample collections, implying the urgency for a comprehensive and intricate investigation of estrogenic fate and contamination in our researched area. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Qiao, Xue; Liu, Chun-Fang; Ji, Shuai; Lin, Xiong-Hao; Guo, De-An; Ye, Min
2014-02-01
Minor phenolic compounds in licorice (Glycyrrhiza uralensis) have recently been proved for diverse bioactivities and favorable bioavailability, indicating that they may play an important role in the therapeutic effects or herb-drug interactions of licorice. However, so far, their abundance in licorice remains unknown. In this study, a reliable solid-phase extraction coupled with a high-performance liquid chromatography and diode array detection method was established to determine the minor phenolic compounds in licorice. The analytes were enriched by a three-step solid-phase extraction method, and then separated on a YMC ODS-A column by gradient elution. Five coumarins and flavonoids were identified by electrospray ionization tandem mass spectrometry, and then quantified using high-performance liquid chromatography and diode array detection. The amounts of glycycoumarin, dehydroglyasperin C, glycyrol, licoflavonol, and glycyrin in G. uralensis were 0.81 ± 0.28, 1.25 ± 0.59, 0.20 ± 0.08, 0.12 ± 0.04, and 0.17 ± 0.08 mg/g, respectively. Abundances of these compounds in other Glycyrrhiza species (G. glabra, G. inflata, and G. yunnanesis) were remarkably lower than G. uralensis. Georg Thieme Verlag KG Stuttgart · New York.
NASA Astrophysics Data System (ADS)
Kassem, Mohammed A.; Amin, Alaa S.
2015-02-01
A new method to estimate rhodium in different samples at trace levels had been developed. Rhodium was complexed with 5-(4‧-nitro-2‧,6‧-dichlorophenylazo)-6-hydroxypyrimidine-2,4-dione (NDPHPD) as a complexing agent in an aqueous medium and concentrated by using Triton X-114 as a surfactant. The investigated rhodium complex was preconcentrated with cloud point extraction process using the nonionic surfactant Triton X-114 to extract rhodium complex from aqueous solutions at pH 4.75. After the phase separation at 50 °C, the surfactant-rich phase was heated again at 100 °C to remove water after decantation and the remaining phase was dissolved using 0.5 mL of acetonitrile. Under optimum conditions, the calibration curve was linear for the concentration range of 0.5-75 ng mL-1 and the detection limit was 0.15 ng mL-1 of the original solution. The enhancement factor of 500 was achieved for 250 mL samples containing the analyte and relative standard deviations were ⩽1.50%. The method was found to be highly selective, fairly sensitive, simple, rapid and economical and safely applied for rhodium determination in different complex materials such as synthetic mixture of alloys and environmental water samples.
Wang, Licheng; Hou, Xiudan; Li, Jubai; Liu, Shujuan; Guo, Yong
2015-07-01
A novel graphene oxide decorated with silver nanoparticles coating on a stainless-steel fiber for solid-phase microextraction was prepared. Scanning electron microscopy and X-ray photoelectron spectroscopy were used to characterize the coating surface and showed that silver nanoparticles were dispersed on the wrinkled graphene oxide surface. Coupled to gas chromatography with flame ionization detection, the extraction abilities of the fiber for polycyclic aromatic hydrocarbons were examined in the headspace solid-phase microextraction mode. The extraction parameters including adsorption time, adsorption temperature, salt concentration, desorption time and desorption temperature were investigated. Under the optimized condition, wide linearity with low limits of detection from 2 to 10 ng/L was obtained. The relative standard deviations for single-fiber repeatability and fiber-to-fiber reproducibility were less than 10.6 and 17.5%, respectively. The enrichment factors were from 1712.5 to 4503.7, showing the fiber has good extraction abilities. Moreover, the fiber exhibited a good stability and could be reused for more than 120 times. The established method was also applied for determination of polycyclic aromatic hydrocarbons in two real water samples and the recoveries of analytes ranged from 84.4-116.3% with relative standard deviations less than 16.2%. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Song, Xuqin; Zhou, Tong; Li, Jiufeng; Zhang, Meiyu; Xie, Jingmeng; He, Limin
2018-05-14
With the extensive application of antibiotics in livestock, their contamination of the aquatic environment has received more attention. Molecularly imprinted polymer (MIP), as an eco-friendly and durable solid-phase extraction material, has shown great potential for the separation and enrichment of antibiotics in water. This study aims at developing a practical and economical method based on molecularly imprinted solid phase extraction (MISPE) combined with liquid chromatography-tandem mass spectrometry (LC-MS/MS) for simultaneously detecting ten macrolide drugs in different sources of water samples. The MIP was synthesized by bulk polymerization using tylosin as the template and methacrylic acid as the functional monomer. The MIP exhibited a favorable load-bearing capacity for water (>90 mL), which is more than triple that of non-molecularly imprinted polymers (NIP). The mean recoveries of macrolides at four spiked concentration levels (limit of quantification, 40, 100, and 400 ng/L) were 62.6⁻100.9%, with intra-day and inter-day relative standard deviations below 12.6%. The limit of detection and limit of quantification were 1.0⁻15.0 ng/L and 3.0⁻40.0 ng/L, respectively. Finally, the proposed method was successfully applied to the analysis of real water samples.
NASA Astrophysics Data System (ADS)
Chen, Suming; Zhang, Zhujun
2008-06-01
The method of synthesis and evaluation of molecularly imprinted polymers was reported. As a selective solid-phase extraction sorbent, the polymers were coupled with electrochemical fluorimetry detection for the efficient determination of methotrexate in serum and urine. Methotrexate was preconcentrated in the molecularly imprinted solid-phase extraction microcolumn packed with molecularly imprinted polymers, and then eluted. The eluate was detected by fluorescence spectrophotometer after electrochemical oxidation. The conditions of preconcentration, elution, electrochemical oxidation and determination were carefully studied. Under the selected experimental conditions, the calibration graph of the fluorescence intensity versus methotrexate concentration was linear from 4 × 10 -9 g mL -1 to 5 × 10 -7 g mL -1, and the detection limit was 8.2 × 10 -10 g mL -1 (3 σ). The relative standard deviation was 3.92% ( n = 7) for 1 × 10 -7 g mL -1 methotrexate. The experiments showed that the selectivity and sensitivity of fluorimetry could be greatly improved by the proposed method. This method has been successfully applied to the determination of methotrexate. At the same time, the binding characteristics of the polymers to the methotrexate were evaluated by batch and dynamic methods.
Autonomous stabilizer for incompressible photon fluids and solids
NASA Astrophysics Data System (ADS)
Ma, Ruichao; Owens, Clai; Houck, Andrew; Schuster, David I.; Simon, Jonathan
2017-04-01
We suggest a simple approach to populate photonic quantum materials at nonzero chemical potential and near-zero temperature. Taking inspiration from forced evaporation in cold-atom experiments, the essential ingredients for our low-entropy thermal reservoir are (a) interparticle interactions and (b) energy-dependent loss. The resulting thermal reservoir may then be coupled to a broad class of Hamiltonian systems to produce low-entropy quantum phases. We present an idealized picture of such a reservoir, deriving the scaling of reservoir entropy with system parameters, and then propose several practical implementations using only standard circuit quantum electrodynamics tools, and extract the fundamental performance limits. Finally, we explore, both analytically and numerically, the coupling of such a thermalizer to the paradigmatic Bose-Hubbard chain, where we employ it to stabilize an n =1 Mott phase. In this case, the performance is limited by the interplay of dynamically arrested thermalization of the Mott insulator and finite heat capacity of the thermalizer, characterized by its repumping rate. This work explores an approach to preparation of quantum phases of strongly interacting photons, and provides a potential route to topologically protected phases that are difficult to reach through adiabatic evolution.
Paramasivam, M; Banerjee, Hemanta
2011-10-01
A sensitive and simple method for simultaneous analysis of flubendiamide and its metabolite desiodo flubendiamide in cabbage, tomato and pigeon pea has been developed. The residues were extracted with QuEChERS method followed by dispersive solid-phase extraction with primary secondary amine sorbent to remove co extractives, prior to analysis by HPLC coupled with UV-Vis detector. The recoveries of flubendiamide and desiodo flubendiamide were ranged from 85.1 to 98.5% and 85.9 to 97.1% respectively with relative standard deviations (RSD) less than 5% and sensitivity of 0.01 μg g(-1). The method offers a less expensive and safer alternative to the existing residue analysis methods for vegetables. © Springer Science+Business Media, LLC 2011
Hu, Chaofan; Jia, Li; Liu, Qingqing; Zhang, Sheng
2010-07-01
A sensitive, fast and simple method based on magnetic octadecylsilane particles was developed for the extraction of three fat-soluble vitamins followed by capillary LC (CLC) analysis with UV detection. Magnetic octadecylsilane particles were prepared based on three-step reactions including co-precipitation, sol-gel polymerization and alkylation. The characterization of the prepared product was studied by scanning electron microscope and Fourier-transform infrared spectrometry. The particles were used as magnetic SPE adsorbent for the extraction of fat-soluble vitamins in fruit juice-milk beverage. The extraction condition and efficiency of the particles for fat-soluble vitamins were investigated. By coupling magnetic SPE with capillary LC with UV detection, low concentrations of fat-soluble vitamins in fruit juice-milk beverage can be detected without the interference from other substances in the sample matrix.
Goryński, Krzysztof; Kiedrowicz, Alicja; Bojko, Barbara
2016-08-05
The current work describes the development and validation of a simple, efficient, and fast method using solid phase microextraction coupled to liquid chromatography-tandem mass spectrometry (SPME-LC-MS/MS) for the concomitant measurement of eight beta-blockers and bronchodilators in plasma and urine. The presented assay enables quantitative determination of acebutolol, atenolol, fenoterol, nadolol, pindolol, procaterol, sotalol, and timolol. In this work, samples were prepared on a high-throughput platform using the 96-well plate format of the thin film solid phase microextraction (TFME) system, and a biocompatible extraction phase made of hydrophilic-lipophilic balance particles. Analytes were separated on a pentafluorophenyl column (100mm×2.1mm, 3μm) by gradient elution using an UPLC Nexera coupled with an LCMS-8060 mass spectrometer. The mobile phase consisted of water-acetonitrile (0.1% formic acid) at a flow rate of 0.4mLmin(-1). The linearity of the method was checked within therapeutic blood-plasma concentrations, and shown to adequately reflect typically expected concentrations of future study samples. Post-extraction addition experiments showed that the matrix effect ranged in plasma from 98% for procaterol to 115% for nadolol, and in urine, from 85% for nadolol and pindolol to 119% for atenolol. The method was successfully validated using Food and Drug Administration (FDA) guidelines, and met all acceptance criteria for bioanalytical assays at five concentration levels for all selected drugs. The final protocol can be successfully applied for monitoring concentrations of the selected drugs in both plasma and urine matrices obtained from patients or athletes. Copyright © 2016 Elsevier B.V. All rights reserved.
Mokbel, Haifaa; Al Dine, Enaam Jamal; Elmoll, Ahmad; Liaud, Céline; Millet, Maurice
2016-04-01
An analytical method associating accelerated solvent extraction (ASE) and solid-phase micro-extraction (SPME) in immersion mode combined with gas chromatography dual electrons capture detectors (SPME-GC-2ECD) has been developed and studied for the simultaneous determination of 19 organochlorine pesticides (OCPs) and 22 polychlorinated biphenyls (PCBs) in air samples (active and XAD-2 passive samplers). Samples were extracted with ASE with acetonitrile using the following conditions: temperature, 150 °C; pressure, 1500 psi; static, 15 min; cycles, 3; purge, 300 s; flush, 100 %. Extracts were reduced to 1 mL, and 500 μL of this extract, filled with deionised water, was subject to SPME extraction. Experimental results indicated that the proposed method attained the best extraction efficiency under the optimised conditions: extraction of PCB-OCP mixture using 100-μm PDMS fibre at 80 °C for 40 min with no addition of salt. The performance of the proposed ASE-SPME-GC-2ECD methodology with respect to linearity, limit of quantification and detection was evaluated by spiking of XAD-2 resin with target compounds. The regression coefficient (R (2)) of most compounds was found to be high of 0.99. limits of detection (LODs) are between 0.02 and 4.90 ng m(-3), and limits of quantification (LOQs) are between 0.05 and 9.12 ng m(-3) and between 0.2 and 49 ng/sampler and 0.52 and 91 ng/sampler, respectively, for XAD-2 passive samplers. Finally, a developed procedure was applied to determine selected PCBs and OCPs in the atmosphere.
Lee, Cholho; Han, Kyung-Hoon; Kim, Kwon-Hyeon; Kim, Jang-Joo
2016-03-21
We have demonstrated a simple and efficient method to fabricate OLEDs with enhanced out-coupling efficiencies and with low pixel blurring by inserting nano-pillar arrays prepared through the lateral phase separation of two immiscible polymers in a blend film. By selecting a proper solvent for the polymer and controlling the composition of the polymer blend, the nano-pillar arrays were formed directly after spin-coating of the polymer blend and selective removal of one phase, needing no complicated processes such as nano-imprint lithography. Pattern size and distribution were easily controlled by changing the composition and thickness of the polymer blend film. Phosphorescent OLEDs using the internal light extraction layer containing the nano-pillar arrays showed a 30% enhancement of the power efficiency, no spectral variation with the viewing angle, and only a small increment in pixel blurring. With these advantages, this newly developed method can be adopted for the commercial fabrication process of OLEDs for lighting and display applications.
Extraction of ochratoxin A in red wine with dopamine-coated magnetic multi-walled carbon nanotubes.
Wan, Hong; Zhang, Bo; Bai, Xiao-Lin; Zhao, Yan; Xiao, Meng-Wei; Liao, Xun
2017-10-01
A new, rapid, green, and cost-effective magnetic solid-phase extraction of ochratoxin A from red wine samples was developed using polydopamine-coated magnetic multi-walled carbon nanotubes as the absorbent. The polydopamine-coated magnetic multi-walled carbon nanotubes were fabricated with magnetic multi-walled carbon nanotubes and dopamine by an in situ oxidative self-polymerization approach. Transmission electron microscopy, dynamic light scattering, X-ray photoelectron spectroscopy and vibrating sample magnetometry were used to characterize the absorbents. Ochratoxin A was quantified with high-performance liquid chromatography coupled with fluorescence detection, with excitation and emission wavelengths of 338 and 455 nm, respectively. The conditions affecting the magnetic solid-phase extraction procedure, such as pH, extraction solution, extraction time, absorbent amount, desorption solution and desorption time were investigated to obtain the optimal extraction conditions. Under the optimized conditions, the extraction recovery was 91.8-104.5% for ochratoxin A. A linear calibration curve was obtained in the range of 0.1-2.0 ng/mL. The limit of detection was 0.07 ng/mL, and the limit of quantitation was 0.21 ng/mL. The recoveries of ochratoxin A for spiked red wine sample ranged from 95.65 to 100.65% with relative standard deviation less than 8%. The polydopamine-coated magnetic multi-walled carbon nanotubes showed a high affinity toward ochratoxin A, allowing selective extraction and quantification of ochratoxin A from complex sample matrixes. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Solliec, Morgan; Massé, Daniel; Sauvé, Sébastien
2014-10-01
A new extraction method coupled to a high throughput sample analysis technique was developed for the determination of four veterinary antibiotics. The analytes belong to different groups of antibiotics such as chemotherapeutics, sulfonamides, lincosamides and macrolides. Trimethoprim (TMP), sulfadoxin (SFX), lincomycin (LCM) and tylosin (TYL) were extracted from lyophilized manure using a sonication extraction. McIlvaine buffer and methanol (MeOH) were used as extraction buffers, followed by cation-exchange solid phase extraction (SPE) for clean-up. Analysis was performed by laser diode thermal desorption-atmospheric pressure chemical-ionization (LDTD-APCI) tandem mass spectrometry (MS/MS) with selected reaction monitoring (SRM) detection. The LDTD is a high throughput sample introduction method that reduces total analysis time to less than 15s per sample, compared to minutes when using traditional liquid chromatography (LC). Various SPE parameters were optimized after sample extraction: the stationary phase, the extraction solvent composition, the quantity of sample extracted and sample pH. LDTD parameters were also optimized: solvent deposition, carrier gas, laser power and corona discharge. The method limit of detection (MLD) ranged from 2.5 to 8.3 µg kg(-1) while the method limit of quantification (MLQ) ranged from 8.3 to 28µgkg(-1). Calibration curves in the manure matrix showed good linearity (R(2)≥ 0.996) for all analytes and the interday and intraday coefficients of variation were below 14%. Recoveries of analytes from manure ranged from 53% to 69%. The method was successfully applied to real manure samples. Copyright © 2014 Elsevier B.V. All rights reserved.
Agrawal, Kavita; Wu, Hui-Fen
2007-01-01
A simple and rapid method based on drop-to-drop solvent microextraction (DDSME) coupled with gas chromatography/mass spectrometry (GC/MS) has been successfully applied for the pharmacokinetic studies of trimeprazine in 8 microL of urine and blood samples of rats. Several factors that influenced the extraction efficiency of DDSME, such as selection of organic solvent, extraction time, exposure volume of organic phase, addition of salt and pH, were optimized. Linearity was obtained over the concentration ranges of 0.2-10, 0.25-7.0 and 0.5-6.0 microg/mL with correlation coefficients of 0.998, 0.996 and 0.993 in deionized water, urine and blood samples of rats, respectively. The limits of detection (LODs) of trimeprazine were 0.05, 0.06 and 0.1 microg/mL in deionized water, urine and blood samples. The concentrations of trimeprazine obtained in urine and blood samples of rats were 0.21-1.25 and 2.72-0.22 microg/mL, respectively, after a single intravenous administration of this drug. The enrichment factors and LOD values obtained by DDSME coupled to GC/MS were compared with those of hollow fiber liquid-phase microextraction (HF-LPME) combined with GC/MS. We believe that this novel approach can be very useful in clinical application since only one microdrop of biological samples was required to perform the pharmacokinetic studies from rats, so the sample pretreatments for animal experiments can be very easy too. Copyright (c) 2007 John Wiley & Sons, Ltd.
Quantitative analysis of three-dimensional biological cells using interferometric microscopy
NASA Astrophysics Data System (ADS)
Shaked, Natan T.; Wax, Adam
2011-06-01
Live biological cells are three-dimensional microscopic objects that constantly adjust their sizes, shapes and other biophysical features. Wide-field digital interferometry (WFDI) is a holographic technique that is able to record the complex wavefront of the light which has interacted with in-vitro cells in a single camera exposure, where no exogenous contrast agents are required. However, simple quasi-three-dimensional holographic visualization of the cell phase profiles need not be the end of the process. Quantitative analysis should permit extraction of numerical parameters which are useful for cytology or medical diagnosis. Using a transmission-mode setup, the phase profile represents the multiplication between the integral refractive index and the thickness of the sample. These coupled variables may not be distinct when acquiring the phase profiles of dynamic cells. Many morphological parameters which are useful for cell biologists are based on the cell thickness profile rather than on its phase profile. We first overview methods to decouple the cell thickness and its refractive index using the WFDI-based phase profile. Then, we present a whole-cell-imaging approach which is able to extract useful numerical parameters on the cells even in cases where decoupling of cell thickness and refractive index is not possible or desired.
Cai, Qizhi; Yang, Zaiyue; Chen, Ning; Zhou, Xuemin; Hong, Junli
2016-07-15
In the present work, an advanced pretreatment method magnetic molecular imprinted polymers-dispersive solid phase extraction (MMIPs-DSPE) combined with the high sensitivity LTQ-Orbitrap mass spectrometry was applied to the complicated metabolites analysis of Traditional Chinese Medicines (TCMs) in complex matrices. The ginsenoside Rb1 magnetic molecular imprinted polymers (Rb1-MMIPs) were successfully synthesized for specific recognition and selective enrichment of Panax notoginseng saponin metabolites in rat faeces. The polymers were prepared by using Fe3O4@SiO2 as the supporting material, APTES as the functional monomer and TEOS as the cross-linker. The Rb1-MMIPs showed quick separation (10.8 emu/g), large adsorption capacity (636μmol/g), high selectivity and fast binding kinetics (25min). Dispersion solid-phase extraction using Rb1-MMIPs (Rb1-MMIPs-DSPE) integrated with LTQ-Orbitrap MS was applied to fish out and identify saponin metabolites from rat faeces, and totally 58 related compounds were detected within 20min, including 26 PPD-group and 32 PPT-group notoginsenoside metabolites. Parallel tests showed that Rb1-MMIPs-DSPE obtained the lowest matrix effects of 0.98-14.84% and captured the largest number of structural analogues compared with traditional pretreatment methods organic solvent extraction (OSE) and solid phase extraction (SPE). Copyright © 2016 Elsevier B.V. All rights reserved.
NASA Technical Reports Server (NTRS)
Gehrke, Charles W.; Ponnamperuma, Cyril; Kuo, Kenneth C.; Stalling, David L.; Zumwalt, Robert W.
1989-01-01
An investigation of the returned Mars samples for biologically important organic compounds, with emphasis on amino acid, the puring and pyrimidine bases, and nucleosides is proposed. These studies would be conducted on subsurface samples obtained by drilling past the surface oxidizing layer with emphasis on samples containing the larges quantities of organic carbon as determined by the rover gas chromatographic mass spectrometer (GCMS). Extraction of these molecules from the returned samples will be performed using the hydrothermal extraction technique described by Cheng and Ponnamperuma. More rigorous extraction methods will be developed and evaluated. For analysis of the extract for free amino acids or amino acids present in a bound or peptidic form, aliquots will be analyzed by capillary GCMS both before and after hydrolysis with 6N hydrochloric acid. Establishment of the presence of amino acids would then lead to the next logical step which would be the use of chiral stationary gas chromatography phases to determine the enatiomeic composition of the amino acids present, and thus potentially establish their biotic or abiotic origin. Confirmational analyses for amino acids would include ion-exchange and reversed-phase liquid chromatographic analysis. For analyses of the returned Mars samples for nucleobases and nucleosides, affinity and reversed-phase liquid chromatography would be utilized. This technology coupled with scanning UV detection for identification, presents a powerful tool for nucleobase and nucleoside analysis. Mass spectrometric analysis of these compounds would confirm their presence in samples returned form Mars.
Zhou, Qingxiang; Lei, Man; Liu, Yongli; Wu, Yalin; Yuan, Yongyong
2017-12-01
Pollution resulted from heavy metal ions have absorbed much attention, and it is of great importance to develop sensitive and simultaneous determination method for them with common technologies without highly sensitive instruments. We prepared a new and functional core-shell magnetic nano-material, Fe@Ag@dimercaptobenzene (Fe@Ag@DMB), by a one-step method with sodium borohydride as the reducing agent and transmission electron microscopy (TEM) and energy dispersive spectrometer (EDS) were used for characterisation. The mercapto functional groups on the newly synthesised magnetic nanoparticles could interact with Cd 2+ , Pb 2+ , and Hg 2+ ions in water samples and then efficient extraction for Cd 2+ , Pb 2+ , and Hg 2+ ions was achieved. DDTC-Na solution was a good elutent for elution of these ions from Fe@Ag@DMB nanoparticles. Based on these, a sensitive method was developed for simultaneous preconcentration and determination of the aforementioned ions using magnetic Fe@Ag@DMB nanoparticles as the magnetic solid phase extraction adsorbent prior to high performance liquid chromatography coupled with variable wavelength detection. Under the optimal conditions, the detection limits of the three metal ions were in the range of 0.011-0.031μgL -1 , and precisions were below 2.37% (n=6). The proposed method was evaluated with real water samples, and excellent spiked recoveries achieved indicated that the developed method would be a promising tool for monitoring these heavy metal ions in water samples. Copyright © 2017 Elsevier B.V. All rights reserved.
Verplanken, Kaat; Wauters, Jella; Van Durme, Jim; Claus, Dirk; Vercammen, Joeri; De Saeger, Sarah; Vanhaecke, Lynn
2016-09-02
Because of animal welfare issues, the voluntary ban on surgical castration of male piglets, starting January 2018 was announced in a European Treaty. One viable alternative is the fattening of entire male pigs. However, this can cause negative consumer reactions due to the occurrence of boar taint and possibly lead to severe economic losses in pig husbandry. In this study, headspace solid phase microextraction (HS-SPME) coupled to GC-MS was used in the development and optimization of a candidate method for fast and accurate detection of the boar taint compounds. Remarkably fast extraction (45s) of the boar taint compounds from adipose tissue was achieved by singeing the fat with a soldering iron while released volatiles were extracted in-situ using HS-SPME. The obtained method showed good performance characteristics after validation according to CD 2002/657/EC and ISO/IEC 17025 guidelines. Moreover, cross-validation with an in-house UHPLC-HR-Orbitrap-MS method showed good agreement between an in-laboratory method and the new candidate method for the fast extraction and detection of skatole and androstenone, which emphasizes the accuracy of this new SPME-GC-MS method. Threshold detection of the boar taint compounds on a portable GC-MS could not be achieved. However, despite the lack of sensitivity obtained on the latter instrument, a very fast method with run-to-run time of 3.5min for the detection of the boar taint compounds was developed. Copyright © 2016 Elsevier B.V. All rights reserved.
Al-Alam, Josephine; Fajloun, Ziad; Chbani, Asma; Millet, Maurice
2017-02-01
The continuous emission of polluting chemicals into the atmosphere requires the implementation of monitoring of ambient air quality. The use of vegetation for environmental monitoring can be considered as a simple monitoring technique by providing a cheap and accessible matrix. In this study, needles of two conifers (Pinus nigra and Cedrus atlantica), were used for the consecutive biomonitoring of multipollutants such as pesticides, polychlorinated biphenyls, and polyaromatic hydrocarbons (PAHs) in an urban area in Strasbourg (France). The extraction was performed by accelerated solvent extraction, solid-phase extraction, and solid-phase microextraction and was followed by gas chromatography coupled to tandem mass spectrometry and liquid chromatography coupled to tandem mass spectrometry analyses. The results obtained for conifer samples collected in 5 successive weeks (April 09-May 07, 2015) show a similar variation of the different types of pollutants. A pollution peak was observed during the second week of analysis, and the concentration of all pollutants then decreased to complete disappearance at the end of the sampling period. PAHs were the most concentrated with a total concentration of about 35.87 ng g -1 , and naphthalene was, among these pollutants, the most concentrated with a total concentration of about 15.1 ng g -1 . The analysis of meteorological data during this period suggests that the results correlated with climatic conditions that widely vary during this period of the year. The results show that the concentration peak was obtained when no precipitation was detected. Copyright © 2016 Elsevier Ltd. All rights reserved.
Adutwum, Lawrence Asamoah; Kishikawa, Naoya; Ohyama, Kaname; Harada, Shiro; Nakashima, Kenichiro; Kuroda, Naotaka
2010-09-01
A sensitive and selective high performance liquid chromatography-peroxyoxalate chemiluminescence (PO-CL) method has been developed for the simultaneous determination of chlorpheniramine (CPA) and monodesmethyl chlorpheniramine (MDCPA) in human serum. The method combines fluorescent labeling with 4-(4,5-diphenyl-1H-imidazole-2-yl)phenyl boronic acid using Suzuki coupling reaction with PO-CL detection. CPA and MDCPA were extracted from human serum by liquid-liquid extraction with n-hexane. Excess labeling reagent, which interfered with trace level determination of analytes, was removed by solid-phase extraction using a C18 cartridge. Separation of derivatives of both analytes was achieved isocratically on a silica column with a mixture of acetonitrile and 60 mM imidazole-HNO(3) buffer (pH 7.2; 85:15, v/v) containing 0.015% triethylamine. The proposed method exhibited a good linearity with a correlation coefficient of 0.999 for CPA and MDCPA within the concentration range of 0.5-100 ng/mL. The limits of detection (S/N = 3) were 0.14 and 0.16 ng/mL for CPA and MDCPA, respectively. Using the proposed method, CPA could be selectively determined in human serum after oral administration.
Tong, Ting; Zhang, Wanfeng; Dai, Wei; He, Sheng; Chang, Zhenyang; Gao, Xuanbo
2014-01-01
A simple and efficient method to analyze the volatile and semivolatile organic compounds in crude oils has been developed based on direct immersion solid-phase microextraction coupled to comprehensive two-dimensional gas chromatography/time-of-flight mass spectrometry (DI-SPME-GC × GC/TOFMS). A novel fiber, multiwalled carbon nanotubes/hydroxyl-terminated silicone oil (MWNTs-TSO-OH), was prepared by sol-gel technology. Using standard solutions, the extraction conditions were optimized such as extraction mode, extraction temperature, extraction time, and salts effect. With the optimized conditions, a real crude oil sample was extracted and then analyzed in detail. It shows that the proposed method is very effective in simultaneously analyzing the normal and branched alkanes, cycloalkanes, aromatic hydrocarbons, and biomarkers of crude oil such as steranes and terpanes. Furthermore, the method showed good linearity (r > 0.999), precision (RSD < 8%), and detection limits ranging from 0.2 to 1.6 ng/L. PMID:24578659
Romera-Torres, Ana; Romero-González, Roberto; Martínez Vidal, José Luis; Garrido Frenich, Antonia
2018-05-01
A new method has been developed for the simultaneous determination of 13 tropane alkaloids in tea and herbal teas using high-performance liquid chromatography coupled to an Exactive-Orbitrap analyzer. A mixture of methanol, water, and formic acid was used for the extraction of the target compounds followed by a solid-phase extraction step. The validated method provided recoveries from 75 to 128% with intra- and interday precision lower than or equal to 24% (except for apoatropine). Limits of quantification ranged from 5 to 20 μg/kg. Eleven tea and herbal tea samples and two contaminated samples with Datura stramonium seeds were analyzed. Tropane alkaloids were detected in six samples with concentrations from 5 (apoatropine) to 4340 μg/kg (sum of physoperuvine, pseudotropine, and tropine), whereas concentrations from 5 (apoatropine) to 1725 μg/kg (sum of physoperuvine, pseudotropine, and tropine) were found in the contaminated samples. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
New phenolic grape skin products from Vitis vinifera cv. Pinot Noir.
Kneknopoulos, Petros; Skouroumounis, George K; Hayasaka, Yoji; Taylor, Dennis K
2011-02-09
Anthocyanins and their related compounds were extracted from grape skins of Pinot noir, using 50% aqueous methanol, and purified by solid phase extraction chromatography using XAD-7 resin to obtain a pigment-rich fraction. This fraction was subjected to multilayer coil countercurrent chromatography (MLCCC) using a quaternary solvent system consisting of tert-butyl methyl ether/n-butanol/acetonitrile/water acidified with 0.01% trifluoroacetic acid (2:2:0.1-1.8:5) (v/v/v/v) in a step gradient elution to separate anthocyanin oligomers from grape anthocyanins. In the process of the characterization of the MLCCC fractions by electrospray mass spectrometry, two noncolored anthocyanin derivatives were found and characterized on the basis of their mass spectral data. As a result, these compounds have been tentatively identified as coupling products between both hydrated malvidin-3-glucoside and peonidin-3-glucoside, with 2-S-glutathionyl caffeoyl tartaric acid (GRP). It is therefore proposed that grape skins contain this new class of coupling product, and a possible chemical pathway for their formation is suggested.
Cao, Jun; Peng, Li-Qing; Du, Li-Jing; Zhang, Qi-Dong; Xu, Jing-Jing
2017-04-22
An ionic liquid-(IL) based micellar extraction combined with microcrystalline cellulose- (MCC) assisted dispersive micro solid-phase extraction method was developed to extract phenolic compounds from propolis. A total of 20 target compounds were identified by ultra-high- performance liquid chromatography coupled with quadrupole time-of-flight tandem mass spectrometry. The main extraction parameters were optimized and included the ultrasonic power, ultrasonic time, sample pH, type of IL, the concentration of [C12mim]Br, extraction time, concentration of MCC, type of sorbent and type of elution solvents. Under the optimum conditions, the proposed method exhibited good linearities (r 2 ≥ 0.999) for all plant phenolic compounds with the lower limits of detection in the range of 0.21-0.41 ng/mL. The recoveries ranged from 82.74% to 97.88% for pinocembrin, chrysin and galangin. Compared with conventional solvent extraction, the present method was simpler and more efficient and required less organic solvent and a shorter extraction time. Finally, the methodology was successfully used for the extraction and enrichment of phenolic compounds in propolis. Copyright © 2017 Elsevier B.V. All rights reserved.
The purpose of this SOP is to describe the acid digestion of soil, house dust, air filter, and surface or dermal wipe samples for analysis using inductively coupled plasma atomic emissions spectrometry (ICP-AES) and/or graphite furnace atomic absorption spectrometry (GFAAS) or fl...
Optical phase locked loop for transparent inter-satellite communications.
Herzog, F; Kudielka, K; Erni, D; Bächtold, W
2005-05-16
A novel type of optical phase locked loop (OPLL), optimized for homodyne inter-satellite communication, is presented. The loop employs a conventional 180? 3 dB optical hybrid and an AC-coupled balanced front end. No residual carrier transmission is required for phase locking. The loop accepts analog as well as digital data and various modulation formats. The only requirement to the transmitted user signal is a constant envelope. Phase error extraction occurs through applying a small sinusoidal local oscillator (LO) phase disturbance, while measuring its impact on the power of the baseband output signal. First experimental results indicate a receiver sensitivity of 36 photons/bit (-55.7 dBm) for a BER of 10 ;-9, when transmitting a PRBS-31 signal at a data rate of 400 Mbit/s. The system setup employs diode-pumped Nd:YAG lasers at a wavelength of 1.06 mum.
Optical phase locked loop for transparent inter-satellite communications
NASA Astrophysics Data System (ADS)
Herzog, F.; Kudielka, K.; Erni, D.; Bächtold, W.
2005-05-01
A novel type of optical phase locked loop (OPLL), optimized for homodyne inter-satellite communication, is presented. The loop employs a conventional 180◦ 3 dB optical hybrid and an AC-coupled balanced front end. No residual carrier transmission is required for phase locking. The loop accepts analog as well as digital data and various modulation formats. The only requirement to the transmitted user signal is a constant envelope. Phase error extraction occurs through applying a small sinusoidal local oscillator (LO) phase disturbance, while measuring its impact on the power of the baseband output signal. First experimental results indicate a receiver sensitivity of 36 photons/bit (-55.7 dBm) for a BER of 10 ^-9, when transmitting a PRBS-31 signal at a data rate of 400 Mbit/s. The system setup employs diode-pumped Nd:YAG lasers at a wavelength of 1.06 μm.
Du, Li-Jing; Huang, Jian-Ping; Wang, Bin; Wang, Chen-Hui; Wang, Qiu-Yan; Hu, Yu-Han; Yi, Ling; Cao, Jun; Peng, Li-Qing; Chen, Yu-Bo; Zhang, Qi-Dong
2018-06-04
A rapid, simple and efficient sample extraction method based on micro-matrix-solid-phase dispersion (micro-MSPD) was applied to the extraction of polyphenols from pomegranate peel. Five target analytes were determined by ultra-high-performance liquid chromatography coupled with quadrupole-time-of-flight mass spectrometry. Carbon molecular sieve (CMS) was firstly used as dispersant to improve extraction efficiency in micro-MSPD. The major micro-MSPD parameters, such as type of dispersant, amount of dispersant, grinding time and the type and the volume of elution solvents, were studied and optimized. Under optimized conditions, 26 mg of pomegranate peel was dispersed with 32.5 mg of CMS, the grinding time was selected as 90 s, the dispersed sample was eluted with 100 μL of methanol. Results showed that the proposed method was of good linearity for concentrations of analytes against their peak areas (coefficient of determination r 2 >0.990), the limit of the detection was as low as 3.2 ng/mL, and the spiking recoveries were between 88.1% and 106%. Satisfactory results were obtained for the extraction of gallic acid, punicalagin A, punicalagin B, catechin and ellagic acid from pomegranate peel sample, which demonstrated nice reliability and high sensitivity of this approach. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.
Li, Wenjing; Lin, Yu; Wang, Yuchun; Hong, Bo
2017-09-11
A method based on a simplified extraction by matrix solid phase dispersion (MSPD) followed by ultra-performance liquid chromatography coupled with the quadrupole time-of-flight tandem mass spectrometry (UPLC/Q-TOF-MS) determination is validated for analysis of two phenolics and three terpenoids in Euphorbia fischeriana . The optimized experimental parameters of MSPD including dispersing sorbent (silica gel), ratio of sample to dispersing sorbent (1:2), elution solvent (water-ethanol: 30-70) and volume of the elution solvent (10 mL) were examined and set down. The highest extraction yields of chromatogram information and the five compounds were obtained under the optimized conditions. A total of 25 constituents have been identified and five components have been quantified from Euphorbia fischeriana . A linear relationship (r² ≥ 0.9964) between the concentrations and the peak areas of the mixed standard substances were revealed. The average recovery was between 92.4% and 103.2% with RSD values less than 3.45% ( n = 5). The extraction yields of two phenolics and three terpenoids obtained by the MSPD were higher than those of traditional reflux and sonication extraction with reduced requirement on sample, solvent and time. In addition, the optimized method will be applied for analyzing terpenoids in other Chinese herbal medicine samples.
Ji, Wenhua; Zhang, Mingming; Yan, Huijiao; Zhao, Hengqiang; Mu, Yan; Guo, Lanping; Wang, Xiao
2017-12-01
We describe a solid-phase extraction adsorbent based on molecularly imprinted polymers (MIPs), prepared with use of a mimic template. The MIPs were used for the selective extraction and determination of three chlorogenic acids as combined quality markers for Lonicera japonica and Lianhua qingwen granules. The morphologies and surface groups of the MIPs were assessed by scanning electron microscopy, Brunauer-Emmett-Teller surface area analysis, and Fourier transform infrared spectroscopy. The adsorption isotherms, kinetics, and selectivity of the MIPs were systematically compared with those of non-molecularly imprinted polymers. The MIPs showed high selectivity toward three structurally similar chlorogenic acids (chlorogenic acid, cryptochlorogenic acid, and neochlorogenic acid). A procedure using molecularly imprinted solid-phase extraction coupled with high-performance liquid chromatography was established for the determination of three chlorogenic acids from Lonicera japonica and Lianhua qingwen granules. The recoveries of the chlorogenic acids ranged from 93.1% to 101.4%. The limits of detection and limits of quantification for the three chlorogenic acids were 0.003 mg g -1 and 0.01 mg g -1 , respectively. The newly developed method is thus a promising technique for the enrichment and determination of chlorogenic acids from herbal medicines. Graphical Abstract Mimic molecularly imprinted polymers for the selective extraction of chlorogenic acids.
NASA Astrophysics Data System (ADS)
Arain, Salma Aslam; Kazi, Tasneem G.; Afridi, Hassan Imran; Abbasi, Abdul Rasool; Panhwar, Abdul Haleem; Naeemullah; Shanker, Bhawani; Arain, Mohammad Balal
2014-12-01
An efficient, innovative preconcentration method, dual-cloud point extraction (d-CPE) has been developed for the extraction and preconcentration of copper (Cu2+) in serum samples of different viral hepatitis patients prior to couple with flame atomic absorption spectrometry (FAAS). The d-CPE procedure was based on forming complexes of elemental ions with complexing reagent 1-(2-pyridylazo)-2-naphthol (PAN), and subsequent entrapping the complexes in nonionic surfactant (Triton X-114). Then the surfactant rich phase containing the metal complexes was treated with aqueous nitric acid solution, and metal ions were back extracted into the aqueous phase, as second cloud point extraction stage, and finally determined by flame atomic absorption spectrometry using conventional nebulization. The multivariate strategy was applied to estimate the optimum values of experimental variables for the recovery of Cu2+ using d-CPE. In optimum experimental conditions, the limit of detection and the enrichment factor were 0.046 μg L-1 and 78, respectively. The validity and accuracy of proposed method were checked by analysis of Cu2+ in certified sample of serum (CRM) by d-CPE and conventional CPE procedure on same CRM. The proposed method was successfully applied to the determination of Cu2+ in serum samples of different viral hepatitis patients and healthy controls.
Neurotransmitters in the Gas Phase: La-Mb Studies
NASA Astrophysics Data System (ADS)
Cabezas, C.; Mata, S.; López, J. C.; Alonso, J. L.
2011-06-01
LA-MB-FTMW spectroscopy combines laser ablation with Fourier transform microwave spectroscopy in supersonic jets overcoming the problems of thermal decomposition associated with conventional heating methods. We present here the results on LA-MB-FTMW studies of some neurotransmitters. Six conformers of dopamine, four of adrenaline, five of noradrenaline and three conformers of serotonin have been characterized in the gas phase. The rotational and nuclear quadrupole coupling constants extracted from the analysis of the rotational spectrum are directly compared with those predicted by ab initio methods to achieve the conclusive identification of different conformers and the experimental characterization of the intramolecular forces at play which control conformational preferences.
Xie, Fuwei; Yu, Jingjing; Wang, Sheng; Zhao, Ge; Xia, Qiaoling; Zhang, Xiaobing; Zhang, Shusheng
2013-10-15
Ten primary aromatic amines (AAs) in mainstream cigarette smoke under both ISO and "Health Canada intensive" machine smoking regimens were determined in this work, which were suspected to be carcinogenic compounds. The measured AAs included aniline, ortho-toluidine, meta-toluidine, para-toluidine, 1-naphthylamine, 2-naphthylamine, 3-aminobiphenyl, 4-aminobiphenyl, meta-phenylenediamine and meta-anisidine. For rapidly and sensitively analyzing these AAs, a liquid chromatography-electrospray ionization tandem mass spectrometric (LC-MS/MS) method coupled with solid phase extraction (SPE) was developed. The particulate phase of mainstream cigarette smoke was collected on a Cambridge filter pads, while the gas phase was trapped by 25 mL 5% HCl solution. Then, the pad was extracted in an ultrasonic bath with the impinger HCl solution. After being neutralized with NaOH, the extract was purified with a HLB solid phase extraction column, and then was analyzed with LC-MS/MS using isotope-labeled internal standard. The overall sample pretreatment and analysis time was less than 1.5h. The limits of detection for all targets ranged from 0.05 ng cig(-1) to 0.96 ng cig(-1) with the recoveries in the range of 75.0-131.8%. And the intra-day and inter-day precisions were less than 10% and 16%, respectively. Under HCI machine smoking regimen, the AAs yields in mainstream cigarette smoke were much higher and the average increases were greater than 100% compared with those under ISO smoking condition. Copyright © 2013 Elsevier B.V. All rights reserved.
Arias, Jean Lucas de Oliveira; Rombaldi, Caroline; Caldas, Sergiane Souza; Primel, Ednei Gilberto
2014-09-19
The clean-up step is essential to reduce interferences, improve quantification and help to maintain the integrity of the chromatographic system when working with complex matrices. In this study, alternative materials were evaluated as sorbents in the dispersive solid-phase extraction (D-SPE) for the determination and extraction of seventeen pesticides from rice paddy soil samples by the quick, easy, cheap, effective, rugged and safe (QuEChERS) method coupled with liquid chromatography-tandem mass spectrometry (LC-MS/MS). Chitin, chitosan, diatomaceous earth and PSA were compared in terms of extraction efficiency and matrix effect. The best results were achieved when chitosan was used. Quantification limits ranged from 0.1 to 100μgkg(-1). Calibration curves showed correlation coefficient values higher than 0.98. Results of accuracy and precision in the spiked soil samples between 60% and 120%, with a relative standard deviation lower than 20%, were reached for 15 out of 17 pesticides. The matrix effect was evaluated and only one compound was influenced by the matrix components, showing medium effect. Results showed that alternative materials are more effective and less expensive than traditional sorbents which have been usually employed, i.e., they may be used in the D-SPE step during the extraction of pesticides from rice paddy soils. Copyright © 2014 Elsevier B.V. All rights reserved.
Liu, Xiaoxing; Xie, Shuyu; Ni, Tengteng; Chen, Dongmei; Wang, Xu; Pan, Yuanhu; Wang, Yulian; Huang, Lingli; Cheng, Guyue; Qu, Wei; Liu, Zhenli; Tao, Yanfei; Yuan, Zonghui
2017-06-01
Carbon nanotubes-magnetic nanoparticles, comprising ferroferric oxide nanoparticles and carbon nanotubes, were prepared through a simple one-step synthesis method and subsequently applied to magnetic solid-phase extraction for the determination of polyether antibiotic and s-triazine drug residues in animal food coupled with liquid chromatography with tandem mass spectrometry. The nanocomposites were characterized by transmission electron microscopy, X-ray diffraction, and vibrating sample magnetometry. The components within the nanocomposites endowed the material with high extraction performance and manipulative convenience. Compared with carbon nanotubes, the as-prepared carbon nanotubes-magnetic nanoparticles showed better extraction and separation efficiencies for polyether antibiotics and s-triazine drugs thanks to the contribution of the iron-containing magnetic nanoparticles. Various experimental parameters affecting the extraction efficiency had been investigated in detail. Under the optimal conditions, the good linearity ranging from 1 to 200 μg/kg for diclazuril, toltrazuril, toltrazuril sulfone, lasalocid, monensin, salinomycin, narasin, nanchangmycin, and maduramicin, low limits of detection ranging from 1 to 5 μg/kg, and satisfactory spiked recoveries (77.1-91.2%, with the inter relative standard deviation values from 4.0 to 12.2%) were shown. It was confirmed that this novel method was an efficient pretreatment and enrichment procedure and could be successfully applied for extraction and determination of polyether and s-triazine drug residues in complex matrices. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Jia, Yuqian; Zhao, Yanfang; Zhao, Mei; Wang, Zhenhua; Chen, Xiangfeng; Wang, Minglin
2018-05-25
A core-shell discoid shaped indium (III) sulfide@metal-organic framework (MIL-125(Ti)) nanocomposite was synthesized by a solvothermal method and explored as an adsorbent material for dispersive solid-phase extraction (d-SPE). The as-synthesized sorbent was characterized by scanning electron microscopy, energy-dispersive spectroscopy, transmission electron microscopy, powder X-ray diffraction, N 2 adsorption-desorption analysis, and Fourier transform infrared spectroscopy. The extraction performance was evaluated by the d-SPE of 16 nitro-polycyclic aromatic hydrocarbons (NPAHs) from water samples. The analysis was carried out by gas chromatography (GC) coupled with triple quadruple mass spectrometer in negative chemical ionization (NCI) mode. The selected ion monitoring (SIM) was used in the quantification of the target NPAHs. Extraction factors affecting the d-SPE, including the ionic strength, extraction temperature, and extraction time were optimized by the response surface methodology. The developed d-SPE method showed good linear correlations from 10 to 1000 ng L -1 (r > 0.99), low detection limits (2.9-83.0 ng L -1 ), satisfactory repeatability (relative standard deviation of <10%, n = 6), and acceptable recoveries (71.3%-112.2%) for water samples. The developed method was used for the food and environmental sample analysis. The results demonstrated that the method could be used for sample preparation of trace NPAHs in real samples. Copyright © 2018. Published by Elsevier B.V.
Socas-Rodríguez, Bárbara; Hernández-Borges, Javier; Herrera-Herrera, Antonio V; Rodríguez-Delgado, Miguel Ángel
2018-03-01
In this work, the suitability of Fe 3 O 4 nanoparticles coated with polydopamine was evaluated as sorbent for the extraction of a group of 21 compounds with oestrogenic activity including seven phytoestrogens, six mycotoxins as well as four synthetic and four natural oestrogens from different types of milk, including sheep milk, in which the evaluation of oestrogenic compounds have never been developed before. Extraction was carried out using magnetic micro-dispersive solid-phase extraction after a previous deproteinisation step. Separation, determination and quantification of the target analytes were achieved by ultra-high-performance liquid chromatography coupled to triple quadrupole-tandem mass spectrometry. The methodology was validated for five milk samples using 17β-estradiol-2,4,16,16,17-d 5 as internal standard for natural and synthetic oestrogens, β-zearalanol-10,10,11,12,12-d 5 for mycotoxins and prunetin for phytoestrogens. Recovery values ranged from 70 to 120% for the five types of matrices with relative standard deviation values lower than 18%. Limits of quantification of the method were in the range 0.55-11.8 μg L -1 for all samples. Graphical abstract General scheme of the multiresidue analysis of oestrogenic compounds in milk using core-shell polydopamine coated magnetic nanoparticles as extraction sorbent in μ-dSPE.
Li, Pingjing; He, Man; Chen, Beibei; Hu, Bin
2015-10-09
A simple home-made automatic dynamic hollow fiber based liquid-liquid-liquid microextraction (AD-HF-LLLME) device was designed and constructed for the simultaneous extraction of organomercury and inorganic mercury species with the assistant of a programmable flow injection analyzer. With 18-crown-6 as the complexing reagent, mercury species including methyl-, ethyl-, phenyl- and inorganic mercury were extracted into the organic phase (chlorobenzene), and then back-extracted into the acceptor phase of 0.1% (m/v) 3-mercapto-1-propanesulfonic acid (MPS) aqueous solution. Compared with automatic static (AS)-HF-LLLME system, the extraction equilibrium of target mercury species was obtained in shorter time with higher extraction efficiency in AD-HF-LLLME system. Based on it, a new method of AD-HF-LLLME coupled with large volume sample stacking (LVSS)-capillary electrophoresis (CE)/UV detection was developed for the simultaneous analysis of methyl-, phenyl- and inorganic mercury species in biological samples and environmental water. Under the optimized conditions, AD-HF-LLLME provided high enrichment factors (EFs) of 149-253-fold within relatively short extraction equilibrium time (25min) and good precision with RSD between 3.8 and 8.1%. By combining AD-HF-LLLME with LVSS-CE/UV, EFs were magnified up to 2195-fold and the limits of detection (at S/N=3) for target mercury species were improved to be sub ppb level. Copyright © 2015 Elsevier B.V. All rights reserved.
Universal Scaling and Critical Exponents of the Anisotropic Quantum Rabi Model.
Liu, Maoxin; Chesi, Stefano; Ying, Zu-Jian; Chen, Xiaosong; Luo, Hong-Gang; Lin, Hai-Qing
2017-12-01
We investigate the quantum phase transition of the anisotropic quantum Rabi model, in which the rotating and counterrotating terms are allowed to have different coupling strengths. The model interpolates between two known limits with distinct universal properties. Through a combination of analytic and numerical approaches, we extract the phase diagram, scaling functions, and critical exponents, which determine the universality class at finite anisotropy (identical to the isotropic limit). We also reveal other interesting features, including a superradiance-induced freezing of the effective mass and discontinuous scaling functions in the Jaynes-Cummings limit. Our findings are extended to the few-body quantum phase transitions with N>1 spins, where we expose the same effective parameters, scaling properties, and phase diagram. Thus, a stronger form of universality is established, valid from N=1 up to the thermodynamic limit.
Universal Scaling and Critical Exponents of the Anisotropic Quantum Rabi Model
NASA Astrophysics Data System (ADS)
Liu, Maoxin; Chesi, Stefano; Ying, Zu-Jian; Chen, Xiaosong; Luo, Hong-Gang; Lin, Hai-Qing
2017-12-01
We investigate the quantum phase transition of the anisotropic quantum Rabi model, in which the rotating and counterrotating terms are allowed to have different coupling strengths. The model interpolates between two known limits with distinct universal properties. Through a combination of analytic and numerical approaches, we extract the phase diagram, scaling functions, and critical exponents, which determine the universality class at finite anisotropy (identical to the isotropic limit). We also reveal other interesting features, including a superradiance-induced freezing of the effective mass and discontinuous scaling functions in the Jaynes-Cummings limit. Our findings are extended to the few-body quantum phase transitions with N >1 spins, where we expose the same effective parameters, scaling properties, and phase diagram. Thus, a stronger form of universality is established, valid from N =1 up to the thermodynamic limit.
Precise determination of lattice phase shifts and mixing angles
Lu, Bing -Nan; Lähde, Timo A.; Lee, Dean; ...
2016-07-09
Here, we introduce a general and accurate method for determining lattice phase shifts and mixing angles, which is applicable to arbitrary, non-cubic lattices. Our method combines angular momentum projection, spherical wall boundaries and an adjustable auxiliary potential. This allows us to construct radial lattice wave functions and to determine phase shifts at arbitrary energies. For coupled partial waves, we use a complex-valued auxiliary potential that breaks time-reversal invariance. We benchmark our method using a system of two spin-1/2 particles interacting through a finite-range potential with a strong tensor component. We are able to extract phase shifts and mixing angles formore » all angular momenta and energies, with precision greater than that of extant methods. We discuss a wide range of applications from nuclear lattice simulations to optical lattice experiments.« less
One-Way Deficit and Quantum Phase Transitions in XX Model
NASA Astrophysics Data System (ADS)
Wang, Yao-Kun; Zhang, Yu-Ran
2018-02-01
Quantum correlations including entanglement and quantum discord have drawn much attention in characterizing quantum phase transitions. Quantum deficit originates in questions regarding work extraction from quantum systems coupled to a heat bath (Oppenheim et al. Phys. Rev. Lett. 89, 180402, 2002). It links quantum thermodynamics with quantum correlations and provides a new standpoint for understanding quantum non-locality. In this paper, we evaluate the one-way deficit of two adjacent spins in the bulk for the XX model. In the thermodynamic limit, the XX model undergoes a first order transition from fully polarized to a critical phase with quasi-long-range order with decrease of quantum parameter. We find that the one-way deficit becomes nonzero after the critical point. Therefore, the one-way deficit characterizes the quantum phase transition in the XX model.
Inukai, Takehito; Kaji, Sanae; Kataoka, Hiroyuki
2018-07-15
Smoking not only increases the risk of lung cancer but is strongly related to the onset of cardiovascular disease. Particularly, passive smoking due to sidestream smoke is a critical public health problem. To assess active and passive exposure to tobacco smoke, we developed a simple and sensitive method, consisting of on-line in-tube solid phase microextraction (SPME) coupled with liquid chromatography-tandem mass spectrometry (LC-MS/MS), to determine nicotine and its metabolite cotinine in hair samples. These compounds were separated within 5 min using a Polar-RP80A column and detected in the positive ion mode by multiple reaction monitoring. The optimum in-tube SPME conditions were 25 draw/eject cycles of 40 μL of sample at a flow rate of 200 μL/min using a Carboxen 1006 capillary column as an extraction device. The extracted compounds in the stationary phase on the inner wall of the capillary could be dissolved easily into the mobile phase and transferred to an LC column. Using the in-tube SPME LC-MS/MS method, the calibration curves were linear in the 5-1000 pg/mL ranges for nicotine and cotinine, and the detection limits (signal to noise ratio of 3) were 0.45 and 0.13 pg/mL, respectively. The intra-day and inter-day precisions were below 3.4% and 6.0% (n = 5), respectively. This method was utilized successfully to analyze pg/mg levels of nicotine and cotinine in 1 mg of hairs without interference peaks, and good recoveries were obtained. The concentration of cotinine in hair was two orders of magnitude lower than that of nicotine, but a good positive correlation was found between the concentrations of these compounds. This method can automate the extraction, concentration and analysis of samples, and is useful for the assessment of long-term exposure to tobacco smoke. Copyright © 2018 Elsevier B.V. All rights reserved.
Soares, Karina Lotz; Cerqueira, Maristela Barnes Rodrigues; Caldas, Sergiane Souza; Primel, Ednei Gilberto
2017-09-01
This study describes the development, optimization and validation of a method for the extraction of 15 pesticides of different chemical classes in drinking water treatment sludge (DWTS) by vortex-assisted Matrix Solid Phase Dispersion (MSPD) with determination by gas chromatography coupled to mass spectrometry. It focused on the application of alternative and different solid supports to the extraction step of the MSPD. The main parameters that influenced the extraction were studied in order to obtain better recovery responses. Recoveries ranged from 70 to 120% with RSD below 20% for all analytes. Limits of quantification (LOQ) of the method ranged from 5 to 500 μg kg -1 whereas the analytical curves showed correlation coefficients above 0.997. The method under investigation used low volume of solvent (5 mL), low sample mass (1.5 g) and low mass of chitin (0.5 g), an environmentally friendly support. It has advantages, such as speed, simplicity and low cost material, over other methods. When the method was applied, 4 out of 15 pesticides were detected in the DWTS samples in concentrations below the LOQ. Copyright © 2017 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Kotrebai, Mihály; Bird, Susan M.; Tyson, Julian F.; Block, Eric; Uden, Peter C.
1999-11-01
Selenium is an essential nutrient for humans; selenium compounds catalyze intermediate metabolism reactions and inhibit the toxic effects of heavy metals such as arsenic, cadmium and mercury. Some extracts of selenium-enriched biological materials show cancer preventive effects, tentatively attributable to the biological functions of selenoamino acids. An improved ion pair chromatographic method with methodological enhancements for the separation, qualitative and quantitative determination of non-volatile selenium compounds extracted from different samples has been developed using ICP-MS as an element-selective detector. Separation power early in the chromatogram was increased to baseline separation in the standard mixture as a result of decreasing spray chamber size from 97 to 14 ml, and increasing trifluoracetic acid (TFA) concentration in the mobile phase from 0.1 to 0.6%. The former pH was restored by the addition of ammonia to the mobile phase, which also served to increase the column recovery of inorganic anions. Calibration curves for different selenoamino acids showed statistically different behavior. Biological sample extracts were characterized using HPLC-ICP-MS. Mass spectral behavior of selenoamino acids, using electrospray and ion trap technology with direct infusion and liquid chromatographic sample introduction, is also reported.
Romero-González, R; Frenich, A Garrido; Vidal, J L Martínez; Aguilera-Luiz, M M
2010-06-30
A new method for the determination of ochratoxin A and T-2 toxin in alcoholic beverages (wine and beer) by hollow fiber liquid microextraction was optimized. The extraction step was followed by ultra high-pressure liquid chromatography coupled to tandem mass spectrometry (UHPLC-MS/MS). The extraction procedure was based on the extraction of mycotoxins from the sample to the organic solvent (1-octanol) immobilized in the fiber, and afterwards, they were desorbed in a mixture of acetonitrile/water (80:20, v/v) at pH 7 prior to chromatographic determination. Different variables affecting the extraction process such as organic solvent, salt content, extraction time and desorption solution were studied. The developed method was validated in wine and beer, using white wine and alcoholic beer as representative matrices for both types of samples. Relative recoveries higher than 70% were obtained for the selected mycotoxins. Good linearity (R(2)>0.993) was obtained and quantification limits (0.02-0.09 microg L(-1)) below European regulatory levels were achieved. Repeatability, expressed as relative standard deviation, was always lower than 12%, whereas interday precision was lower than 21%. The proposed method was applied to the analysis of several types of wines and beers and ochratoxin A was detected in a rosé wine at 1.1 microg L(-1). Copyright 2010 Elsevier B.V. All rights reserved.
Kori, Shivpoojan; Parmar, Ankush; Goyal, Jony; Sharma, Shweta
2018-02-01
A procedure for the determination of Eszopiclone (ESZ) from complex matrices i.e. in vitro (spiked matrices), as well as in vivo (mice model) was developed using cloud point extraction coupled with microwave-assisted back-extraction (CPE-MABE). Analytical measurements have been carried using UV-Visible, HPLC and MS techniques. The proposed method has been validated according to ICH guidelines and legitimate reproducible and reliability of protocol is assessed through intraday and inter-day precision <3.61% and <4.70%, respectively. Limit of detection has been obtained as 0.083μg/mL and 0.472μg/mL respectively, for HPLC and UV-Visible techniques, corresponding to assessed linearity range. The coaservate phase in CPE was back extracted under microwaves exposure, with isooctane at pre-concentration factor ~50 when 5mL of sample solution was pre-concentrated to 0.1mL. Under optimized conditions i.e. Aqueous-Triton X-114 4% (w/v), pH4.0, NaCl 4% (w/v) and equilibrium temperature of 45°C for 20min, average extraction recovery has been obtained between 89.8 and 99.2% and 84.0-99.2% from UV-Visible and HPLC analysis, respectively. The method has been successfully applied to the pharmacokinetic estimation (post intraperitoneal administration) of ESZ in mice. MS analysis precisely depicted the presence of active N‑desmethyl zopiclone in impales as well as in mice plasma. Copyright © 2018 Elsevier B.V. All rights reserved.
Zhang, Caixiang; Eganhouse, Robert P.; Pontolillo, James; Cozzarelli, Isabelle M.; Wang, Yanxin
2012-01-01
4-Nonylphenols (4-NPs) are known endocrine disruptors and by-products of the microbial degradation of nonylphenol polyethoxylate surfactants. One of the challenges to understanding the toxic effects of nonylphenols is the large number of isomers that may exist in environmental samples. In order to attribute toxic effects to specific compounds, a method is needed for the separation and quantitation of individual nonylphenol isomers. The pre-concentration methods of solvent sublimation, solid-phase extraction or liquid–liquid extraction prior to chromatographic analysis can be problematic because of co-extraction of thousands of compounds typically found in complex matrices such as municipal wastewater or landfill leachate. In the present study, steam distillation extraction (SDE) was found to be an effective pre-concentration method for extraction of 4-NPs from leachate and wastewater, and comprehensive two-dimensional gas chromatography (GC × GC) coupled with fast mass spectral data acquisition by time-of-flight mass spectrometry (ToFMS) enhanced the resolution and identification of 4-NP isomers. Concentrations of eight 4-NP isomers were determined in leachate from landfill cells of different age and wastewater influent and effluent samples. 4-NP isomers were about 3 times more abundant in leachate from the younger cell than the older one, whereas concentrations in wastewater effluent were either below detection limits or <1% of influent concentrations. 4-NP isomer distribution patterns were found to have been altered following release to the environment. This is believed to reflect isomer-specific degradation and accumulation of 4-NPs in the aquatic environment.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yang, Xi; Huang, Xiaobiao
2016-05-13
Here, we propose a method to simultaneously correct linear optics errors and linear coupling for storage rings using turn-by-turn (TbT) beam position monitor (BPM) data. The independent component analysis (ICA) method is used to isolate the betatron normal modes from the measured TbT BPM data. The betatron amplitudes and phase advances of the projections of the normal modes on the horizontal and vertical planes are then extracted, which, combined with dispersion measurement, are used to fit the lattice model. The fitting results are used for lattice correction. Finally, the method has been successfully demonstrated on the NSLS-II storage ring.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yang, Xi; Huang, Xiaobiao
2016-08-01
We propose a method to simultaneously correct linear optics errors and linear coupling for storage rings using turn-by-turn (TbT) beam position monitor (BPM) data. The independent component analysis (ICA) method is used to isolate the betatron normal modes from the measured TbT BPM data. The betatron amplitudes and phase advances of the projections of the normal modes on the horizontal and vertical planes are then extracted, which, combined with dispersion measurement, are used to fit the lattice model. Furthermore, the fitting results are used for lattice correction. Our method has been successfully demonstrated on the NSLS-II storage ring.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yang, Xi; Huang, Xiaobiao
2016-08-01
We propose a method to simultaneously correct linear optics errors and linear coupling for storage rings using turn-by-turn (TbT) beam position monitor (BPM) data. The independent component analysis (ICA) method is used to isolate the betatron normal modes from the measured TbT BPM data. The betatron amplitudes and phase advances of the projections of the normal modes on the horizontal and vertical planes are then extracted, which, combined with dispersion measurement, are used to fit the lattice model. The fitting results are used for lattice correction. The method has been successfully demonstrated on the NSLS-II storage ring.
Bach, Benoit; Cleroux, Marilyn; Saillen, Mayra; Schönenberger, Patrik; Burgos, Stephane; Ducruet, Julien; Vallat, Armelle
2016-12-15
The concentrations of α/β-thujone and the bitter components of Artemisia absinthium were quantified from alcoholic wormwood extracts during four phenological stages of their harvest period. A solid-phase micro-extraction method coupled to gas chromatography-mass spectrometry was used to determine the concentration of the two isomeric forms of thujone. In parallel, the combination of ultra-high pressure liquid chromatography and high resolution mass spectrometry allowed to quantify the compounds absinthin, artemisetin and dihydro-epi-deoxyarteannuin B. This present study aimed at helping absinthe producers to determine the best harvesting period. Copyright © 2016 Elsevier Ltd. All rights reserved.
Manaf, Normaliza Abdul; Saad, Bahruddin; Mohamed, Mohamed H; Wilson, Lee D; Latiff, Aishah A
2018-03-30
Sorbents were prepared by cross-linking β-cyclodextrin (β-CD) using two different types of cross-linker units at variable reactant mole ratios. The resulting polymers containing β-CD were evaluated as sorbents in micro-solid phase extraction (μ-SPE) format for the extraction of the endogenous steroids testosterone (T), epitestosterone (E), androsterone (A), etiocholanolone (Etio), 5α-androstane-3α,17β-diol (5αAdiol) and 5β-androstane-3α,17β-diol (5βAdiol). The best sorbent (C1; cyclodextrin polymer) showed superior extraction characteristics compared with commercial sorbents (C18 and Bond Elut Plexa). Parameters influencing the extraction efficiency of the C1 sorbent such as extraction and desorption times, desorption solvent and volume of sample were investigated. The extracts were separated using a Hypersil Gold column (50 × 2.1 mm, 1.9 μm) under gradient elution coupled to a LC-MS/MS. The compounds were successfully separated within 8 min. The method offers good repeatability (RSD < 10%) and linearity (r 2 > 0.995) were within the range of 1-200 ng mL -1 for T and E, 250-4000 ng mL -1 for A and Etio and 25-500 ng mL -1 for 5αAdiol and 5βAdiol, respectively. The method was applied for the determination of steroid profile of urine from volunteers. Copyright © 2018 Elsevier B.V. All rights reserved.
Alonso-Salces, Rosa M; Barranco, Alejandro; Corta, Edurne; Berrueta, Luis A; Gallo, Blanca; Vicente, Francisca
2005-02-15
A solid-liquid extraction procedure followed by reversed-phase high-performance liquid chromatography (RP-HPLC) coupled with a photodiode array detector (DAD) for the determination of polyphenols in freeze-dried apple peel and pulp is reported. The extraction step consists in sonicating 0.5g of freeze-dried apple tissue with 30mL of methanol-water-acetic acid (30:69:1, v/v/v) containing 2g of ascorbic acid/L, for 10min in an ultrasonic bath. The whole method was validated, concluding that it is a robust method that presents high extraction efficiencies (peel: >91%, pulp: >95%) and appropriate precisions (within day: R.S.D. (n = 5) <5%, and between days: R.S.D. (n = 5) <7%) at the different concentration levels of polyphenols that can be found in apple samples. The method was compared with one previously published, consisting in a pressurized liquid extraction (PLE) followed by RP-HPLC-DAD determination. The advantages and disadvantages of both methods are discussed.
Orčić, Dejan; Francišković, Marina; Bekvalac, Kristina; Svirčev, Emilija; Beara, Ivana; Lesjak, Marija; Mimica-Dukić, Neda
2014-01-15
A method for quantification of 45 plant phenolics (including benzoic acids, cinnamic acids, flavonoid aglycones, C- and O-glycosides, coumarins, and lignans) in plant extracts was developed, based on reversed phase HPLC separation of extract components, followed by tandem mass spectrometric detection. The phenolic profile of 80% MeOH extracts of the stinging nettle (Urtica dioica L.) herb, root, stem, leaf and inflorescence was obtained by using this method. Twenty-one of the investigated compounds were present at levels above the reliable quantification limit, with 5-O-caffeoylquinic acid, rutin and isoquercitrin as the most abundant. The inflorescence extracts were by far the richest in phenolics, with the investigated compounds amounting 2.5-5.1% by weight. As opposed to this, the root extracts were poor in phenolics, with only several acids and derivatives being present in significant amounts. The results obtained by the developed method represent the most detailed U. dioica chemical profile so far. Copyright © 2013 Elsevier Ltd. All rights reserved.
Rivoira, Luca; Studzińska, Sylwia; Szultka-Młyńska, Malgorzata; Bruzzoniti, Maria Concetta; Buszewski, Bogusław
2017-08-01
Betaine is one of most studied biologically active compounds, due its role in the main biological processes. Although it may be found in several plants and roots, such as the Beta vulgaris family, present in typical diets, just a few analytical methods have been developed for its extraction from roots. A new, quick and effective procedure for the isolation and determination of betaine from two different varieties of B. vulgaris (red and gold) is presented. For betaine extraction, an accelerated solvent extraction (ASE) was coupled with solid-phase extraction. For betaine determination, a separation method based on hydrophilic interaction chromatography coupled with tandem mass spectrometry was optimized for a sensible detection of betaine by means of experimental design. Recoveries were about 93%, with RSD <5%, for both the matrices, without evidence of interfering species. The total content of betaine in extracts of various parts of plants (juice, peel, root) have been determined, obtaining concentrations in the range 3000-4000 mg/L for the juice and in the range 2-5 mg/g for the pulp and for the peel. The B. vulgaris gold species exhibited a higher concentration of betaine, compared to the red variety. Additionally, a micro extraction by packed sorbent technique and a modified quick, easy, cheap, rugged and safe (QuEChERS) procedure, were also tested and compared. Despite the lower recoveries of the latter, with respect to the ASE/SPE procedure (75-89%, RSD <1.5%), the ease of the method, which can be applied without the SPE purification procedure, can represent a positive improvement. Graphical abstract Determination of betaine from Beta vulgaris samples.
Zhang, Xiao-Mei; Chen, Yi-Long; Yao, Yuan-Yuan; Li, Na; Liu, You-Ping; Liang, Xu-Ming
2016-03-01
Using six kinds of ionic liquids as extractants, ultrasonic-assisted extraction coupled with HPLC method was developed for the simultaneous determination of wilforgine, wiforizine, triptophenolide, wilforine and triptoquinone A in Tripterygium hypoglaucum. The separation was performed on an Inertsil ODS-4 column with the mobile phase of acetonitrile-0.1% phosphoric acid in gradient elution at a flow rate of 0.75 mL•min⁻¹. Detection wavelength was 220 nm and the column temperature was 30℃. Under the optimal extractions, the results showed that triptophenolide and triptoquinone A had the highest extraction yield by using 0.6 mol•L⁻¹ [BMIm]PF6 methanol solution as extraction solvent with the solid-liquid ratio of 1∶10. The calibration curves of triptophenolide and triptoquinone A showed a good linearity in the range of 0.000 65-0.026, 0.066 55-2.662 μg (r=0.999 9)respectively. The average recovery was 102.4% and 97.90% with RSD of 2.5% and 1.5%, respectively. Wilforgine, wiforizine and wilforine had the highest extraction yield when using 0.6 mol• L⁻¹ [BMIm]PF6absolute ethanol solution as extraction solvent with the solid-liquid ratio of 1∶10. The content of wilforgine, wiforizine and wilforine from 0.023 9-0.956, 0.002 7-0.108, 0.006 4-0.256 μg showed a good linearity (r=0.999 9), and the average recovery was 100.6%,99.50% and 98.70% with RSD of 2.1%,1.9% and 2.7%, respectively. The results indicated that this method is convenient, reliable and green, and can be used as a reliableanalytical method for the quality control of T.hypoglaucum. Copyright© by the Chinese Pharmaceutical Association.
Segro, Scott S; Cabezas, Yaniel; Malik, Abdul
2009-05-15
A sol-gel titania poly(tetrahydrofuran) (poly-THF) coating was developed for capillary microextraction hyphenated on-line with high-performance liquid chromatography (HPLC). Poly-THF was covalently bonded to the sol-gel titania network which, in turn, became chemically anchored to the inner surface of a 0.25mm I.D. fused silica capillary. For sample preconcentration, a 38-cm segment of the sol-gel titania poly-THF coated capillary was installed on an HPLC injection port as a sampling loop. Aqueous samples containing a variety of analytes were passed through the capillary and, during this process, the analytes were extracted by the sol-gel titania poly-THF coating on the inner surface of the capillary. Using isocratic and gradient elution with acetonitrile/water mobile phases, the extracted analytes were desorbed into the on-line coupled HPLC column for separation and UV detection. The sol-gel titania poly-THF coating was especially efficient in extracting polar analytes, such as underivatized phenols, alcohols, amines, and aromatic carboxylic acids. In addition, this coating was capable of extracting moderately polar and nonpolar analytes, such as ketones and polycyclic aromatic hydrocarbons. The sol-gel titania poly-THF coated capillary was also able to extract polypeptides at pH values near their respective isoelectric points. Extraction of these compounds can be important for environmental and biomedical applications. The observed extraction behavior can be attributed to the polar and nonpolar moieties in the poly-THF structure. This coating was found to be stable under extremely low and high pH conditions-even after 18h of exposure to 1M HCl (pH approximately 0.0) and 1M NaOH (pH approximately 14.0).
The setup of an extraction system coupled to a hydrogen isotopes distillation column
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zamfirache, M.; Bornea, A.; Stefanescu, I.
2008-07-15
Among the most difficult problems of cryogenic distillation one stands apart: the extraction of the heavy fraction. By an optimal design of the cycle scheme, this problem could be avoided. A 'worst case scenario' is usually occurring when the extracted fraction consists of one prevalent isotope such as hydrogen and small amounts of the other two hydrogen isotopes (deuterium and/or tritium). This situation is further complicated by two parameters of the distillation column: the extraction flow rate and the hold-up. The present work proposes the conceptual design of an extraction system associated to the cryogenic distillation column used in hydrogenmore » separation processes. During this process, the heavy fraction (DT, T{sub 2}) is separated, its concentration being the highest at the bottom of the distillation column. From this place the extraction of the gaseous phase can now begin. Being filled with adsorbent, the extraction system is used to temporarily store the heavy fraction. Also the extraction system provides samples for the gas Chromatograph. The research work is focused on the existent pilot plant for tritium and deuterium separation from our institute to validate the experiments carried out until now. (authors)« less
Casado, Natalia; Pérez-Quintanilla, Damián; Morante-Zarcero, Sonia; Sierra, Isabel
2017-04-01
A SBA-15 type mesoporous silica was synthesized and bi-functionalized with octadecylsilane (C18) or octylsilane (C8), and sulfonic acid (SO 3 - ) groups in order to obtain materials with reversed-phase/strong cation-exchange mixed-mode retention mechanism. The resulting hybrid materials (SBA-15-C18-SO 3 - and SBA-15-C8-SO 3 - ) were comprehensively characterized. They showed high surface area, high pore volume and controlled porous size. Elemental analysis of the materials revealed differences in the amount of C18 and C8. SBA-15-C18-SO 3 - contained 0.19mmol/g of C18, while SBA-15-C8-SO 3 - presented 0.54mmol/g of C8. The SO 3 - groups anchored to the silica surface of the pore walls were 0.20 and 0.09mmol/g, respectively. The bi-functionalized materials were evaluated as SPE sorbents for the multi-residue extraction of 26 veterinary drug residues in meat samples using ultra-high-performance liquid chromatography coupled to mass spectrometry detector (UHPLC-MS/MS). Different sorbent amounts (100 and 200mg) and organic solvents were tested to optimize the extraction procedure. Both silicas showed big extraction potential and were successful in the extraction of the target analytes. The mixed-mode retention mechanism was confirmed by comparing both silicas with SBA-15 mesoporous silica mono-functionalized with C18 and C8. Best results were achieved with 200mg of SBA-15-C18-SO 3 - obtaining recoveries higher than 70% for the majority of analytes. Copyright © 2016 Elsevier B.V. All rights reserved.
Medvedovici, Andrei; Albu, Florin; Naşcu-Briciu, Rodica Domnica; Sârbu, Costel
2014-02-01
Discrimination power evaluation of UV-Vis and (±) electrospray ionization/mass spectrometric techniques, (ESI-MS) individually considered or coupled as detectors to reversed phase liquid chromatography (RPLC) in the characterization of Ginkgo Biloba standardized extracts, is used in herbal medicines and/or dietary supplements with the help of Fuzzy hierarchical clustering (FHC). Seventeen batches of Ginkgo Biloba commercially available standardized extracts from seven manufacturers were measured during experiments. All extracts were within the criteria of the official monograph dedicated to dried refined and quantified Ginkgo extracts, in the European Pharmacopoeia. UV-Vis and (±) ESI-MS spectra of the bulk standardized extracts in methanol were acquired. Additionally, an RPLC separation based on a simple gradient elution profile was applied to the standardized extracts. Detection was made through monitoring UV absorption at 220 nm wavelength or the total ion current (TIC) produced through (±) ESI-MS analysis. FHC was applied to raw, centered and scaled data sets, for evaluating the discrimination power of the method with respect to the origins of the extracts and to the batch to batch variability. The discrimination power increases with the increase of the intrinsic selectivity of the spectral technique being used: UV-Vis
Chao, Yu-Ying; Jian, Zhi-Xuan; Tu, Yi-Ming; Wang, Hsaio-Wen; Huang, Yeou-Lih
2013-06-07
In this study, we employed a novel on-line method, push/pull perfusion hollow-fiber liquid-phase microextraction (PPP-HF-LPME), to extract 4-tert-butylphenol, 2,4-di-tert-butylphenol, 4-n-nonylphenol, and 4-n-octylphenol from river and tap water samples; we then separated and quantified the extracted analytes through high-performance liquid chromatography (HPLC). Using this approach, we overcame the problem of fluid loss across the porous HF membrane to the donor phase, permitting on-line coupling of HF-LPME to HPLC. In our PPP-HF-LPME system, we used a push/pull syringe pump as the driving source to perfuse the acceptor phase, while employing a heating mantle and an ultrasonic probe to accelerate mass transfer. We optimized the experimental conditions such as the nature of the HF supported intermediary phase and the acceptor phase, the composition of the donor and acceptor phases, the sample temperature, and the sonication conditions. Our proposed method provided relative standard deviations of 3.1-6.2%, coefficients of determination (r(2)) of 0.9989-0.9998, and limits of detection of 0.03-0.2 ng mL(-1) for the analytes under the optimized conditions. When we applied this method to analyses of river and tap water samples, our results confirmed that this microextraction technique allows reliable monitoring of alkylphenols in water samples.
NASA Astrophysics Data System (ADS)
Menegário, Amauri A.; Silva, Ariovaldo José; Pozzi, Eloísa; Durrant, Steven F.; Abreu, Cassio H.
2006-09-01
The yeast Saccharomyces cerevisiae was immobilized in cubes of polyurethane foam and the ability of this immobilized material to separate Sb(III) and Sb(V) was investigated. A method based on sequential determination of total Sb (after on-line reduction of Sb(V) to Sb(III) with thiourea) and Sb(III) (after on-line solid-liquid phase extraction) by hydride generation inductively coupled plasma optical emission spectrometry is proposed. A flow system assembled with solenoid valves was used to manage all stages of the process. The effects of pH, sample loading and elution flow rates on solid-liquid phase extraction of Sb(III) were evaluated. Also, the parameters related to on-line pre-reduction (reaction coil and flow rates) were optimized. Detection limits of 0.8 and 0.15 μg L - 1 were obtained for total Sb and Sb(III), respectively. The proposed method was applied to the analysis of river water and effluent samples. The results obtained for the determination of total Sb were in agreement with expected values, including the river water Standard Reference Material 1640 certified by the National Institute of Standards and Technology (NIST). Recoveries of Sb(III) and Sb(V) in spiked samples were between 81 ± 19 and 111 ±15% when 120 s of sample loading were used.
Yin, Yong-guang; Chen, Ming; Peng, Jin-feng; Liu, Jing-fu; Jiang, Gui-bin
2010-06-15
A novel and simple solid phase extraction (SPE)-high performance liquid chromatography (HPLC)-inductively coupled plasma mass spectrometry (ICP-MS) method was developed for determination of inorganic mercury (IHg), methylmercury MeHg and ethylmercury (EtHg) in water samples in the present work. The procedure involves pre-functionalization of the commercially available C18 SPE column with dithizone, loading water sample, displacement elution of mercury species by Na(2)S(2)O(3) solution, followed by HPLC-ICP-MS determination. Characterization and optimization of operation parameters of this new SPE procedure were discussed, including eluting reagent selection, concentration of eluting reagent, volume of eluting reagent, effect of NaCl and humic acid in sample matrix. At optimized conditions, the detection limits of mercury species for 100mL water sample were about 3ngL(-1) and the average recoveries were 93.7, 83.4, and 71.7% for MeHg, IHg and EtHg, respectively, by spiking 0.2microgL(-1) mercury species into de-ion water. Stability experiment reveals that both the dithizone-functionalized SPE cartridge and the mercury species incorporated were stable in the storage procedure. These results obtained demonstrate that SPE-HPLC-ICP-MS is a simple and sensitive technique for the determination of mercury species at trace level in water samples with high reproducibility and accuracy.
Vissers, Anne; Kiskini, Alexandra; Hilgers, Roelant; Marinea, Marina; Wierenga, Peter Alexander; Gruppen, Harry; Vincken, Jean-Paul
2017-06-21
Sugar beet (Beta vulgaris L.) leaves of 8 month (8 m ) plants showed more enzymatic browning than those of 3 month (3 m ). Total phenolic content increased from 4.6 to 9.4 mg/g FW in 3 m and 8 m , respectively, quantitated by reverse-phase-ultrahigh-performance liquid chromatography-ultraviolet-mass spectrometry (RP-UHPLC-UV-MS). The PPO activity was 6.7 times higher in extracts from 8 m than from 3 m leaves. Substrate content increased from 0.53 to 2.45 mg/g FW in 3 m and 8 m , respectively, of which caffeic acid glycosyl esters were most important, increasing 10-fold with age. Caffeic acid glycosides and vitexin derivatives were no substrates. In 3 m and 8 m, nonsubstrate-to-substrate ratios were 8:1 and 3:1, respectively. A model system showed browning at 3:1 ratio due to formation of products with extensive conjugated systems through oxidative coupling and coupled oxidation. The 8:1 ratio did not turn brown as oxidative coupling occurred without much coupled oxidation. We postulate that differences in nonsubstrate-to-substrate ratio and therewith extent of coupled oxidation explain browning.
2017-01-01
Sugar beet (Beta vulgaris L.) leaves of 8 month (8m) plants showed more enzymatic browning than those of 3 month (3m). Total phenolic content increased from 4.6 to 9.4 mg/g FW in 3m and 8m, respectively, quantitated by reverse-phase-ultrahigh-performance liquid chromatography–ultraviolet-mass spectrometry (RP-UHPLC–UV-MS). The PPO activity was 6.7 times higher in extracts from 8m than from 3m leaves. Substrate content increased from 0.53 to 2.45 mg/g FW in 3m and 8m, respectively, of which caffeic acid glycosyl esters were most important, increasing 10-fold with age. Caffeic acid glycosides and vitexin derivatives were no substrates. In 3m and 8m, nonsubstrate-to-substrate ratios were 8:1 and 3:1, respectively. A model system showed browning at 3:1 ratio due to formation of products with extensive conjugated systems through oxidative coupling and coupled oxidation. The 8:1 ratio did not turn brown as oxidative coupling occurred without much coupled oxidation. We postulate that differences in nonsubstrate-to-substrate ratio and therewith extent of coupled oxidation explain browning. PMID:28570816
Karimi, Shima; Talebpour, Zahra; Adib, Noushin
2016-06-14
A poly acrylate-ethylene glycol (PA-EG) thin film is introduced for the first time as a novel polar sorbent for sorptive extraction method coupled directly to solid-state spectrofluorimetry without the necessity of a desorption step. The structure, polarity, fluorescence property and extraction performance of the developed thin film were investigated systematically. Carvedilol was used as the model analyte to evaluate the proposed method. The entire procedure involved one-step extraction of carvedilol from plasma using PA-EG thin film sorptive phase without protein precipitation. Extraction variables were studied in order to establish the best experimental conditions. Optimum extraction conditions were the followings: stirring speed of 1000 rpm, pH of 6.8, extraction temperature of 60 °C, and extraction time of 60 min. Under optimal conditions, extraction of carvedilol was carried out in spiked human plasma; and the linear range of calibration curve was 15-300 ng mL(-1) with regression coefficient of 0.998. Limit of detection (LOD) for the method was 4.5 ng mL(-1). The intra- and inter-day accuracy and precision of the proposed method were evaluated in plasma sample spiked with three concentration levels of carvedilol; yielding a recovery of 91-112% and relative standard deviation of less than 8%, respectively. The established procedure was successfully applied for quantification of carvedilol in plasma sample of a volunteer patient. The developed PA-EG thin film sorptive phase followed by solid-state spectrofluorimetric method provides a simple, rapid and sensitive approach for the analysis of carvedilol in human plasma. Copyright © 2016 Elsevier B.V. All rights reserved.
Lucci, Paolo; Moret, Sabrina; Bettin, Sara; Conte, Lanfranco
2017-01-01
The aim of this work was to evaluate the use of a molecularly imprinted polymer as a selective solid-phase extraction sorbent for the clean-up and pre-concentration of patulin from apple-based food products. Ultra high pressure liquid chromatography coupled to ultraviolet absorbance detection was used for the analysis of patulin. The molecularly imprinted polymer was applied, for the first time, to the determination of patulin in apple juice, puree and jam samples spiked within the maximum levels specified by the European Commission No. 1881/2006. High recoveries (>77%) were obtained. The method was validated and found to be linear in the range 2-100 μg/kg with correlation coefficients greater than 0.965 and repeatability relative standard deviation below 11% in all cases. Compared with dispersive solid-phase extraction (QuEChERS method) and octadecyl sorbent, the molecularly imprinted polymer showed higher recoveries and selectivity for patulin. The application of Affinisep molecularly imprinted polymer as a selective sorbent material for detection of patulin fulfilled the method performance criteria required by the Commission Regulation No. 401/2006, demonstrating the suitability of the technique for the control of patulin at low ppb levels in different apple-based foods such as juice, puree and jam samples. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Complexation-induced supramolecular assembly drives metal-ion extraction.
Ellis, Ross J; Meridiano, Yannick; Muller, Julie; Berthon, Laurence; Guilbaud, Philippe; Zorz, Nicole; Antonio, Mark R; Demars, Thomas; Zemb, Thomas
2014-09-26
Combining experiment with theory reveals the role of self-assembly and complexation in metal-ion transfer through the water-oil interface. The coordinating metal salt Eu(NO3)3 was extracted from water into oil by a lipophilic neutral amphiphile. Molecular dynamics simulations were coupled to experimental spectroscopic and X-ray scattering techniques to investigate how local coordination interactions between the metal ion and ligands in the organic phase combine with long-range interactions to produce spontaneous changes in the solvent microstructure. Extraction of the Eu(3+)-3(NO3(-)) ion pairs involves incorporation of the "hard" metal complex into the core of "soft" aggregates. This seeds the formation of reverse micelles that draw the water and "free" amphiphile into nanoscale hydrophilic domains. The reverse micelles interact through attractive van der Waals interactions and coalesce into rod-shaped polynuclear Eu(III) -containing aggregates with metal centers bridged by nitrate. These preorganized hydrophilic domains, containing high densities of O-donor ligands and anions, provide improved Eu(III) solvation environments that help drive interfacial transfer, as is reflected by the increasing Eu(III) partitioning ratios (oil/aqueous) despite the organic phase approaching saturation. For the first time, this multiscale approach links metal-ion coordination with nanoscale structure to reveal the free-energy balance that drives the phase transfer of neutral metal salts. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Kassem, Mohammed A; Amin, Alaa S
2015-02-05
A new method to estimate rhodium in different samples at trace levels had been developed. Rhodium was complexed with 5-(4'-nitro-2',6'-dichlorophenylazo)-6-hydroxypyrimidine-2,4-dione (NDPHPD) as a complexing agent in an aqueous medium and concentrated by using Triton X-114 as a surfactant. The investigated rhodium complex was preconcentrated with cloud point extraction process using the nonionic surfactant Triton X-114 to extract rhodium complex from aqueous solutions at pH 4.75. After the phase separation at 50°C, the surfactant-rich phase was heated again at 100°C to remove water after decantation and the remaining phase was dissolved using 0.5mL of acetonitrile. Under optimum conditions, the calibration curve was linear for the concentration range of 0.5-75ngmL(-1) and the detection limit was 0.15ngmL(-1) of the original solution. The enhancement factor of 500 was achieved for 250mL samples containing the analyte and relative standard deviations were ⩽1.50%. The method was found to be highly selective, fairly sensitive, simple, rapid and economical and safely applied for rhodium determination in different complex materials such as synthetic mixture of alloys and environmental water samples. Copyright © 2014 Elsevier B.V. All rights reserved.
Xiao, Qin; Hu, Bin; Duan, Jiankun; He, Man; Zu, Wanqing
2007-10-01
A novel method for the analysis of four polybrominated diphenyl ethers (PBDEs) in environmental and human serum samples based on hollow fiber-liquid phase microextraction (HF-LPME) followed by gas chromatography-inductively coupled plasma mass spectrometric (GC-ICP-MS) detection has been developed. The organic solvent in the porous hollow fiber was first dipped into the sample for extraction at a given time, and the retracted organic phase was introduced into the GC-ICP-MS for analysis. The addition of methanol has a strong effect on the HF-LPME extraction efficiency. Other significant parameters affecting the extraction efficiency of HF-LPME were also studied. HF-LPME was effective to isolate the analytes from the complex matrix. Under the optimized conditions, the detection limits of the proposed method varied from 15.2 to 40.5 ng/L. In general, the relative standard deviations (RSDs) were less than 10%. Good linearity was obtained with the correlation coefficients all better than 0.999. The proposed method is simple, quick, few microliters of organic solvent required, and is especially suitable for the analysis of the real sample with small amount available. The overall process of HF-LPME with GC-ICP-MS was applied successfully for the determination of polybrominated diphenyl ethers (PBDEs) in environmental and spiked human serum samples, and the results were satisfactory.
Sonker, Mukul; Knob, Radim; Sahore, Vishal; Woolley, Adam T
2017-07-01
Integration in microfluidics is important for achieving automation. Sample preconcentration integrated with separation in a microfluidic setup can have a substantial impact on rapid analysis of low-abundance disease biomarkers. Here, we have developed a microfluidic device that uses pH-mediated solid-phase extraction (SPE) for the enrichment and elution of preterm birth (PTB) biomarkers. Furthermore, this SPE module was integrated with microchip electrophoresis for combined enrichment and separation of multiple analytes, including a PTB peptide biomarker (P1). A reversed-phase octyl methacrylate monolith was polymerized as the SPE medium in polyethylene glycol diacrylate modified cyclic olefin copolymer microfluidic channels. Eluent for pH-mediated SPE of PTB biomarkers on the monolith was optimized using different pH values and ionic concentrations. Nearly 50-fold enrichment was observed in single channel SPE devices for a low nanomolar solution of P1, with great elution time reproducibility (<7% RSD). The monolith binding capacity was determined to be 400 pg (0.2 pmol). A mixture of a model peptide (FA) and a PTB biomarker (P1) was extracted, eluted, injected, and then separated by microchip electrophoresis in our integrated device with ∼15-fold enrichment. This device shows important progress towards an integrated electrokinetically operated platform for preconcentration and separation of biomarkers. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
NASA Astrophysics Data System (ADS)
Jimenez-Martinez, J.; Porter, M. L.; Hyman, J.; Carey, J. W.; Viswanathan, H. S.
2015-12-01
Although the mixing of fluids within a porous media is a common process in natural and industrial systems, how the degree of mixing depends on the miscibility of multiple phases is poorly characterized. Often, the direct consequence of miscible mixing is the modification of the resident fluid (brine and hydrocarbons) rheological properties. We investigate supercritical (sc)CO2 displacement and mixing processes in a three-phase system (scCO2, oil, and H2O) using a microfluidics experimental system that accommodates the high pressures and temperatures encountered in fossil fuel extraction operations. The miscibility of scCO2 with the resident fluids, low with aqueous solutions and high with hydrocarbons, impacts the mixing processes that control sweep efficiency in enhanced oil recovery (EOR) and the unlocking of the system in unconventional oil and gas extraction. Using standard volume-averaging techniques we upscale the aqueous phase saturation to the field-scale (i.e., Darcy scale) and interpret the results as a simpler two-phase system. This process allows us to perform a statistical analysis to quantify i) the degree of heterogeneity in the system resulting from the immiscible H2O and ii) how that heterogeneity impacts mixing between scCO2 and oil and their displacement. Our results show that when scCO2 is used for miscible displacement, the presence of an aqueous solution, which is common in secondary and tertiary EOR and unconventional oil and gas extraction, strongly impacts the mixing of scCO2 with the hydrocarbons due to low scCO2-H2O miscibility. H2O, which must be displaced advectively by the injected scCO2, introduces spatio-temporal variability into the system that acts as a barrier between the two miscibile fluids. This coupled with the effect of viscosity contrast, i.e., viscous fingering, has an impact on the mixing of the more miscible pair.
Damm, Markus; Kappe, C Oliver
2011-11-30
A high-throughput platform for performing parallel solvent extractions in sealed HPLC/GC vials inside a microwave reactor is described. The system consist of a strongly microwave-absorbing silicon carbide plate with 20 cylindrical wells of appropriate dimensions to be fitted with standard HPLC/GC autosampler vials serving as extraction vessels. Due to the possibility of heating up to four heating platforms simultaneously (80 vials), efficient parallel analytical-scale solvent extractions can be performed using volumes of 0.5-1.5 mL at a maximum temperature/pressure limit of 200°C/20 bar. Since the extraction and subsequent analysis by either gas chromatography or liquid chromatography coupled with mass detection (GC-MS or LC-MS) is performed directly from the autosampler vial, errors caused by sample transfer can be minimized. The platform was evaluated for the extraction and quantification of caffeine from commercial coffee powders assessing different solvent types, extraction temperatures and times. For example, 141±11 μg caffeine (5 mg coffee powder) were extracted during a single extraction cycle using methanol as extraction solvent, whereas only 90±11 were obtained performing the extraction in methylene chloride, applying the same reaction conditions (90°C, 10 min). In multiple extraction experiments a total of ~150 μg caffeine was extracted from 5 mg commercial coffee powder. In addition to the quantitative caffeine determination, a comparative qualitative analysis of the liquid phase coffee extracts and the headspace volatiles was performed, placing special emphasis on headspace analysis using solid-phase microextraction (SPME) techniques. The miniaturized parallel extraction technique introduced herein allows solvent extractions to be performed at significantly expanded temperature/pressure limits and shortened extraction times, using standard HPLC autosampler vials as reaction vessels. Remarkable differences regarding peak pattern and main peaks were observed when low-temperature extraction (60°C) and high-temperature extraction (160°C) are compared prior to headspace-SPME-GC-MS performed in the same HPLC/GC vials. Copyright © 2011 Elsevier B.V. All rights reserved.
Pérez-Olivero, S. J.; Pérez-Pont, M. L.; Conde, J. E.; Pérez-Trujillo, J. P.
2014-01-01
Application of headspace solid-phase microextraction (HS-SPME) coupled with high-resolution gas chromatographic (HRGC) analysis was studied for determining lactones in wines. Six different SPME fibers were tested, and the influence of different factors such as temperature and time of desorption, ionic strength, time of extraction, content of sugar, ethanol, tannins and anthocyanins, and pH and influence of SO2 were studied. The proposed HS-SPME-GC method is an appropriate technique for the quantitative analysis of γ-butyrolactone, γ-hexalactone, trans-whiskey lactone, γ-octalactone, cis-whiskey lactone, γ-nonalactone, γ-decalactone, δ-decalactone, and γ-undecalactone in wines. Method reproducibility and repeatability ranged between 0.6 and 5.2% for all compounds. Detection limit for γ-butyrolactone was 0.17 mg/L and a few μg/L for the rest of the compounds. The optimized method has been applied to several wine samples. PMID:24782943
Sun, Tonghua; Jia, Jinping; Zhong, Dengjie; Wang, Yalin
2006-02-01
Activated carbon fiber (ACF) as extraction fiber for solid-phase microextraction (SPME) and its application for the analysis of banned organochlorine pesticides (OCPs) were investigated. Firstly, ACF was activated by different concentration of zinc chloride, which indicated that ACF activated by 60% zinc chloride had a reasonable specific surface area, pore volume and pore distribution. Secondly, the parameters for the ACF-SPME procedure, the adsorption and desorption conditions, were also optimized when coupled with gas chromatography-mass spectrometry (GC-MS). Thirdly, the ACF-SPME was used to analyze 17 kinds of OCPs in water. The linearity of most pesticides was found to be between 0.2 and 50 microg/l with GC-MS under the selected ion monitoring (SIM) acquisition mode. The limits of detection (LOD) at the sub microg/l were obtained. The work demonstrated here shows that ACF is a promising alternative for the SPME procedure.
He, Jiao; Zhang, Yongmin; Ito, Yoichiro; Sun, Wenji
2011-01-01
Coupled with evaporative light scattering detection, a high-speed counter-current chromatography (HSCCC) method was applied to the separation and purification of three tauro-conjugated cholic acids of taurochenodeoxycholic acid (TCDCA), taurohyodeoxycholic acid (THDCA) and taurohyocholic acid (THCA) from Pulvis Fellis Suis (Pig gallbladder bile) for the first time. The two-phase solvent system composed of chloroform-methanol-water-acetic acid (4:4:2:0.3, v/v/v/v) was selected for the one-step separation where the lower phase was used as the mobile phase in the head to tail elution mode. The revolution speed of the separation column, flow rate of the mobile phase and separation temperature were 800 rpm, 1.5 ml/min and 25°C respectively. From 100 mg of the crude extract, 10.2 mg of TCDCA, 11.8 mg of THDCA and 5.3 mg of THCA were obtained with the purity of 94.6%, 96.5% and 95.4%, respectively. in one step separation The HSCCC fractions were analyzed by high-performance liquid chromatography (HPLC) and the structures of the three tauro-conjugated cholic acids were identified by ESI-MS, (1)H NMR and (13)C NMR.
Zheng, Hao-Bo; Ding, Jun; Zheng, Shu-Jian; Zhu, Gang-Tian; Yuan, Bi-Feng; Feng, Yu-Qi
2016-01-01
In this study, we proposed a method to fabricate magnetic carbon nitride (CN) nanosheets by simple physical blending. Low-cost CN nanosheets prepared by urea possessed a highly π-conjugated structure; therefore the obtained composites were employed as magnetic solid-phase extraction (MSPE) sorbent for extraction of polycyclic aromatic hydrocarbons (PAHs) in edible oil samples. Moreover, sample pre-treatment time could be carried out within 10 min. Thus, a simple and cheap method for the analysis of PAHs in edible oil samples was established by coupling magnetic CN nanosheets-based MSPE with gas chromatography-mass spectrometry (GC/MS) analysis. Limits of quantitation (LOQs) for eight PAHs ranged from 0.4 to 0.9 ng/g. The intra- and inter-day relative standard deviations (RSDs) were less than 15.0%. The recoveries of PAHs for spiked soybean oil samples ranged from 91.0% to 124.1%, with RSDs of less than 10.2%. Taken together, the proposed method offers a simple and cost-effective option for the convenient analysis of PAHs in oil samples. Copyright © 2015 Elsevier B.V. All rights reserved.
Salisaeng, Pawina; Arnnok, Prapha; Patdhanagul, Nopbhasinthu; Burakham, Rodjana
2016-03-16
A vortex-assisted dispersive micro-solid phase extraction (VA-D-μ-SPE) based on cetyltrimethylammonium bromide (CTAB)-modified zeolite NaY was developed for preconcentration of carbamate pesticides in fruits, vegetables, and natural surface water prior to analysis by high performance liquid chromatography with photodiode array detection. The small amounts of solid sorbent were dispersed in a sample solution, and extraction occurred by adsorption in a short time, which was accelerated by vortex agitation. Finally, the sorbents were filtered from the solution, and the analytes were subsequently desorbed using an appropriate solvent. Parameters affecting the VA-D-μ-SPE performance including sorbent amount, sample volume, desorption solvent ,and vortex time were optimized. Under the optimum condition, linear dynamic ranges were achieved between 0.004-24.000 mg kg(-1) (R(2) > 0.9946). The limits of detection (LODs) ranged from 0.004-4.000 mg kg(-1). The applicability of the developed procedure was successfully evaluated by the determination of the carbamate residues in fruits (dragon fruit, rambutan, and watermelon), vegetables (cabbage, cauliflower, and cucumber), and natural surface water.
Li, Xiujuan; Zeng, Zhaorui; Zeng, Yi
2007-06-15
This paper investigates the detection of 2,3-dimethyl-2,3-dinitrobutane (DMNB), a marking agent in explosives, by gas chromatography (GC) with electron capture detection using solid-phase microextraction (SPME) as a sample preparation technique. The 25,27-dihydroxy-26,28-oxy (2',7'-dioxo-3',6'-diazaoctyl) oxy-p-tert-butylcalix[4]arene/hydroxy-terminated silicone oil coated fiber was highly sensitive to trap DMNB from ammonium nitrate matrix. The analysis was performed by extracting 2g of explosives for 30s at room temperature and then immediately introducing into the heated GC injector for 1min of thermal desorption. The method showed good linearity in the range from 0.01 to 1.0mug/g. The relative standard deviations for these extractions were <8%. The calculated limit of detection for DMNB (S/N=3) was 4.43x10(-4)mug/g, which illustrates that the proposed systems are suitable for explosive detection at trace level. This is the first report of an SPME-GC system shown to extract marking agent in explosives for subsequent detection in a simple, rapid, sensitive, and inexpensive manner.
He, Huan; Zhuang, Yuan; Peng, Ying; Gao, Zhanqi; Yang, Shaogui; Sun, Cheng
2014-02-01
A porous and highly efficient polyaniline-based solid-phase microextraction (SPME) coating was successfully prepared by the electrochemical deposition method. A method based on headspace SPME followed by HPLC was established to rapidly determine trace chlorophenols in water samples. Influential parameters for the SPME, including extraction mode, extraction temperature and time, pH and ionic strength procedures, were investigated intensively. Under the optimized conditions, the proposed method was linear in the range of 0.5-200 μg/L for 4-chlorophenol and 2,4,6-trichlorophenol, 0.2-200 μg/L for 2,4-dichlorophenol and 2-200 μg/L for 2,3,4,6-tetrachlorophenol and pentachlorophenol, with satisfactory correlation coefficients (>0.99). RSDs were <15% (n = 5) and LODs were relatively low (0.10-0.50 μg/L). Compared to commercial 85 μm polyacrylate and 60 μm polydimethylsiloxane/divinylbenzene fibers, the homemade polyaniline fiber showed a higher extraction efficiency. The proposed method has been successfully applied to the determination of chlorophenols in water samples with satisfactory recoveries. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Zheng, Yaqiu; Liu, Yahong; Guo, Hongbin; He, Limin; Fang, Binghu; Zeng, Zhenling
2011-04-01
A simple, sensitive and reproducible molecularly imprinted solid-phase extraction (MISPE) coupled with high performance liquid chromatographic method was developed for monitoring tilmicosin in feeds. The polymers were prepared using tylosin as mimic template molecule, methacrylic acid as functional monomer and ethylene glycol dimethacrylate as cross-linking monomer, and chloroform as a solvent by bulk polymerization. Under the optimum MISPE conditions, the novel polymer sorbent can selectively extract and enrich tilmicosin from variety of feeds. The MISPE cartridge was better than non-imprinted, C(18) and HLB cartridges in terms of both recovery and precision. Mean recoveries of tilmicosin from five kinds of feeds spiked at 1, 10 and 50 mg kg(-1) ranged from 76.9% to 95.6%, with intra-day and inter-day relative standard deviation less than 7.6%. The linearity was ranged from 1.0 to 100 mg L(-1) for matrix standard solution (r=0.9990). The limit of detection was approximately 0.35 mg kg(-1) and the limit of quantification was approximately 0.98 mg kg(-1). There was cleaner chromatogram by using MISPE than C(18) and HLB SPE. Copyright © 2011 Elsevier B.V. All rights reserved.
Letseka, Thabiso
2017-01-01
We report the application of the dispersive liquid-liquid microextraction coupled to hollow-fibre membrane-assisted liquid-phase microextraction and its application for extraction of atrazine and triclosan. Under optimum conditions, namely, 25 μL of a 1 : 4 chlorobenzene : ethyl acetate mixture dispersed in 1 mL of aqueous sample, 10% (m/v) NaCl, a magnetic stirrer speed at 600 rpm, and 10 minutes' extraction time with toluene-filled fibre as the acceptor phase, the method demonstrates sufficient figures of merit. These include linearity (R2 ≥ 0.9975), intravial precision (%RSD ≤ 7.6), enrichment factors (127 and 142), limits of detection (0.0081 and 0.0169 µg/mL), and recovery from river water and sewerage (96–101%). The relatively high detection limits are attributed to the flame ionization detector which is less preferred than a mass spectrometer in trace analyses. This is the first report of a homogenous mixture of the dispersed organic solvent in aqueous solutions and its employment in extraction of organic compounds from aqueous solutions. It therefore adds yet another candidate in the pool of miniaturised solvent microextraction techniques. PMID:29158736
NASA Astrophysics Data System (ADS)
Zhang, Li; Chang, Xijun; Li, Zhenhua; He, Qun
2010-02-01
A new selective solid-phase extractant using activated carbon as matrix which was purified, oxidized and modified by triethylenetetramine (AC-TETA) was prepared and characterized by FT-IR spectroscopy. At pH 4, quantitative extraction of trace Cr(III), Fe(III) and Pb(II) was obtained and determined by inductively coupled plasma optical emission spectrometry (ICP-OES). Complete elution of the adsorbed metal ions from the sorbent surface was carried out using 0.5 mol L -1 HCl. The maximum static adsorption capacity of sorbent for Cr(III), Fe(III) and Pb(II) was 34.6, 36.5 and 51.9 mg g -1, respectively. The time of quantitative adsorption was less than 2 min. The detection limits of the method was found to be 0.71, 0.35 and 0.45 ng mL -1 for Cr(III), Fe(III) and Pb(II), and the relative standard deviation (RSD) was 3.7%, 2.2% and 2.5%, respectively. Moreover, the method was free from interference with common coexiting ions. The method was also successfully applied to the preconcentration of trace Cr(III), Fe(III) and Pb(II) in synthetic samples and a real sample with satisfactory results.
Xu, Lili; Feng, Juanjuan; Li, Jubai; Liu, Xia; Jiang, Shengxiang
2012-01-01
A novel chemically bonded graphene oxide/fused-silica fiber was prepared and applied in solid-phase microextraction of six polycyclic aromatic hydrocarbons from water samples coupled with gas chromatography. It exhibited high extraction efficiency and excellent stability. Effects of extraction time, extraction temperature, ionic strength, stirring rate and desorption conditions were investigated and optimized in our work. Detection limits to the six polycyclic aromatic hydrocarbons were less than 0.08 μg/L, and their calibration curves were all linear (R(2)≥0.9954) in the range from 0.05 to 200 μg/L. Single fiber repeatability and fiber-to-fiber reproducibility were less than 6.13 and 15.87%, respectively. This novel fiber was then utilized to analyze two real water samples from the Yellow River and local waterworks, and the recoveries of samples spiked at 1 and 10 μg/L ranged from 84.48 to 118.24%. Compared with other coating materials, this graphene oxide-coated fiber showed many advantages: wide linear range, low detection limit, and good stability in acid, alkali, organic solutions and at high temperature. Copyright © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
NASA Astrophysics Data System (ADS)
Trottier, H. D.; Shakespeare, N. H.; Lepage, G. P.; MacKenzie, P. B.
2002-05-01
Perturbative coefficients for Wilson loops and the static-quark self-energy are extracted from Monte Carlo simulations at weak coupling. The lattice volumes and couplings are chosen to ensure that the lattice momenta are all perturbative. Twisted boundary conditions are used to eliminate the effects of lattice zero modes and to suppress nonperturbative finite-volume effects due to Z(3) phases. Simulations of the Wilson gluon action are done with both periodic and twisted boundary conditions, and over a wide range of lattice volumes (from 34 to 164) and couplings (from β~9 to β~60). A high precision comparison is made between the simulation data and results from finite-volume lattice perturbation theory. The Monte Carlo results are shown to be in excellent agreement with perturbation theory through second order. New results for third-order coefficients for a number of Wilson loops and the static-quark self-energy are reported.
Evans, Sian E; Davies, Paul; Lubben, Anneke; Kasprzyk-Hordern, Barbara
2015-07-02
This is the first study presenting a multi-residue method allowing for comprehensive analysis of several chiral pharmacologically active compounds (cPACs) including beta-blockers, antidepressants and amphetamines in wastewater and digested sludge at the enantiomeric level. Analysis of both the liquid and solid matrices within wastewater treatment is crucial to being able to carry out mass balance within these systems. The method developed comprises filtration, microwave assisted extraction and solid phase extraction followed by chiral liquid chromatography coupled with tandem mass spectrometry to analyse the enantiomers of 18 compounds within all three matrices. The method was successfully validated for 10 compounds within all three matrices (amphetamine, methamphetamine, MDMA, MDA, venlafaxine, desmethylvenlafaxine, citalopram, metoprolol, propranolol and sotalol), 7 compounds validated for the liquid matrices only (mirtazapine, salbutamol, fluoxetine, desmethylcitalopram, atenolol, ephedrine and pseudoephedrine) and 1 compound (alprenolol) passing the criteria for solid samples only. The method was then applied to wastewater samples; cPACs were found at concentration ranges in liquid matrices of: 1.7 ng L(-1) (metoprolol) - 1321 ng L(-1) (tramadol) in influent,
Chen, Di; Zheng, Hao-Bo; Huang, Yun-Qing; Hu, Yu-Ning; Yu, Qiong-Wei; Yuan, Bi-Feng; Feng, Yu-Qi
2015-08-21
Ambient ionization techniques show good potential in rapid analysis of target compounds. However, a direct application of these ambient ionization techniques for the determination of analytes in a complex matrix is difficult due to the matrix interference and ion suppression. To resolve this problem, here we developed a strategy by coupling magnetic solid phase extraction (MSPE) with desorption corona beam ionization (DCBI)-mass spectrometry (MS). As a proof of concept, the pyrrole-coated Fe3O4 magnetic nanoparticles (Fe3O4@Ppy) were prepared and used for the extraction of antidepressants. After extraction, the Fe3O4@Ppy with trapped antidepressants was then directly subjected to DCBI-MS analysis with the aid of a homemade magnetic glass capillary. As the MSPE process is rapid and the direct DCBI-MS analysis does not need solvent desorption or chromatographic separation processes, the overall analysis can be completed within 3 min. The proposed MSPE-DCBI-MS method was then successfully used to determine antidepressants in human urine and plasma. The calibration curves were obtained in the range of 0.005-0.5 μg mL(-1) for urine and 0.02-1 μg mL(-1) for plasma with reasonable linearity (R(2) > 0.951). The limits of detection of three antidepressants were in the range of 0.2-1 ng mL(-1) for urine and 2-5 ng mL(-1) for plasma. Acceptable reproducibility for rapid analysis was achieved with relative standard deviations less than 19.1% and the relative recoveries were 85.2-118.7%. Taken together, the developed MSPE-DCBI-MS strategy offers a powerful capacity for rapid analysis of target compounds in a complex matrix, which would greatly expand the applications of ambient ionization techniques with plentiful magnetic sorbents.
Verplaetse, Ruth; Henion, Jack
2016-07-05
A workflow overcoming microsample collection issues and hematocrit (HCT)-related bias would facilitate more widespread use of dried blood spots (DBS). This report describes comparative results between the use of a pipet and a microfluidic-based sampling device for the creation of volumetric DBS. Both approaches were successfully coupled to HCT-independent, fully automated sample preparation and online liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS) analysis allowing detection of five stimulants in finger prick blood. Reproducible, selective, accurate, and precise responses meeting generally accepted regulated bioanalysis guidelines were observed over the range of 5-1000 ng/mL whole blood. The applied heated flow-through solvent desorption of the entire spot and online solid phase extraction (SPE) procedure were unaffected by the blood's HCT value within the tested range of 28.0-61.5% HCT. Enhanced stability for mephedrone on DBS compared to liquid whole blood was observed. Finger prick blood samples were collected using both volumetric sampling approaches over a time course of 25 h after intake of a single oral dose of phentermine. A pharmacokinetic curve for the incurred phentermine was successfully produced using the described validated method. These results suggest that either volumetric sample collection method may be amenable to field-use followed by fully automated, HCT-independent DBS-SPE-LC-MS/MS bioanalysis for the quantitation of these representative controlled substances. Analytical data from DBS prepared with a pipet and microfluidic-based sampling devices were comparable, but the latter is easier to operate, making this approach more suitable for sample collection by unskilled persons.
Miniature flowing atmospheric-pressure afterglow ion source for facile interfacing of CE with MS.
Jecklin, Matthias C; Schmid, Stefan; Urban, Pawel L; Amantonico, Andrea; Zenobi, Renato
2010-10-01
Here, we present a miniaturized version of the flowing atmospheric-pressure afterglow (miniFAPA) ion source and use it for sheathless coupling of CE with MS. The simple design of the CE-miniFAPA-MS interface makes it easy to separate the electric potentials used for CE and for ionization. A pneumatically assisted nebulization of the CE effluent transfers the analytes from the liquid phase into the gas phase before they are ionized by interacting with reactive species produced by the FAPA. An important advantage of this interface is its high stability during operation: optimization of five different parameters indicated that the interface is not sensitive to minor deviations from the optimum values. Other advantages include ease of construction and maintenance, as well as relatively low cost. Samples with complex matrices, such as yeast extract, soil extract and urine, spiked with the test compounds, were successfully analyzed using the CE-miniFAPA-MS setup.
Xu, Hui; Jia, Li
2009-01-01
A capillary liquid chromatography (CLC) system with UV/vis detection was coupled with an in-tube solid-phase microextraction (SPME) device for the analysis of fat-soluble vitamins and beta-carotene. A monolithic silica-ODS column was used as the extraction medium. An optical-fiber flow cell with a long light path in the UV/vis detector was utilized to further enhance the detection sensitivity. In the in-tube SPME/CLC system, the pre-condition of the extraction column and the effect of the injection volume were investigated. The detection limits (LOD) for the fat-soluble vitamins and beta-carotene were in the range from 1.9 to 173 ng/mL based on the signal-to-noise ratio of 3 (S/N=3). The relative standard deviations of migration time and peak area for each analyte were less than 5.0%. The method was applied to the analysis of fat-soluble vitamins and beta-carotene contents in corns.
Solid Phase Microextraction and Related Techniques for Drugs in Biological Samples
Moein, Mohammad Mahdi; Said, Rana; Bassyouni, Fatma
2014-01-01
In drug discovery and development, the quantification of drugs in biological samples is an important task for the determination of the physiological performance of the investigated drugs. After sampling, the next step in the analytical process is sample preparation. Because of the low concentration levels of drug in plasma and the variety of the metabolites, the selected extraction technique should be virtually exhaustive. Recent developments of sample handling techniques are directed, from one side, toward automatization and online coupling of sample preparation units. The primary objective of this review is to present the recent developments in microextraction sample preparation methods for analysis of drugs in biological fluids. Microextraction techniques allow for less consumption of solvent, reagents, and packing materials, and small sample volumes can be used. In this review the use of solid phase microextraction (SPME), microextraction in packed sorbent (MEPS), and stir-bar sorbtive extraction (SBSE) in drug analysis will be discussed. In addition, the use of new sorbents such as monoliths and molecularly imprinted polymers will be presented. PMID:24688797
Schultz, M.M.; Furlong, E.T.
2008-01-01
Treated wastewater effluent is a potential environmental point source for antidepressant pharmaceuticals. A quantitative method was developed for the determination of trace levels of antidepressants in environmental aquatic matrixes using solid-phase extraction coupled with liquid chromatography- electrospray ionization tandem mass spectrometry. Recoveries of parent antidepressants from matrix spiking experiments for the individual antidepressants ranged from 72 to 118% at low concentrations (0.5 ng/L) and 70 to 118% at high concentrations (100 ng/L) for the solid-phase extraction method. Method detection limits for the individual antidepressant compounds ranged from 0.19 to 0.45 ng/L. The method was applied to wastewater effluent and samples collected from a wastewater-dominated stream. Venlafaxine was the predominant antidepressant observed in wastewater and river water samples. Individual antidepressant concentrations found in the wastewater effluent ranged from 3 (duloxetine) to 2190 ng/L (venlafaxine), whereas individual concentrations in the waste-dominated stream ranged from 0.72 (norfluoxetine) to 1310 ng/L (venlafaxine). ?? 2008 American Chemical Society.
Zhao, Haixiang; Liu, Haiping; Yan, Zaoying
2014-03-01
A multi-residue analytical method based on solid-phase extraction (SPE) with multiwalled carbon nanotubes (MWCNTs) as sorbent was developed. The determination of the sulfonamides (SAs) in pork and chicken was carried out by high performance liquid chromatography-ultraviolet detection (HPLC-UV). The clean-up conditions were optimized. The analytes were extracted by acetonitril and cleaned-up by MWCNTs SPE cartridge. The extract was redissolved with the Na2HPO4 buffer (pH 5.5-6.0) for loading, and was washed with acetone-hexane (5:95, v/v), then eluted with acetone-dichloromethane (1:1, v/v) from the column. The mobile phase used in the chromatographic separation consisted of a binary mixture of acetonitrile and 50 mmol/L NaH2PO4 with the volume ratio of 7:3. A wide linear range was 0.01-1.00 mg/L with the correlation coefficients above 0.998. The limits of detection (S/N = 3) were 0.003 mg/L, and the limits of quantification (S/N = 10) were 0.01 mg/L. The average recoveries were over 70% for the nine SAs in the spiked range of 0.02-0.2 mg/kg, with the relative standard deviations (RSDs) lower than 8%. This study indicated that the MWCNTs SPE cartridge is efficient for the clean-up of the SAs in animal tissues or products, and the method is simple, accurate and suitable for the quantification of the SAs residues.
Yang, Xueyu; Liu, Mingren; Wang, Zhongpeng; Li, Qian; Zhang, Zhaoliang
2013-08-01
Octylphenols, considered as xenoestrogens, mainly exist as 4-tert-octylphenol (OP) in aquatic environments. The high stability and accumulation of OP in aquatic systems have caused endocrine disruption. The OP in surface water in Jinan, China was analyzed by gas chromatography-mass spectrometry (GC-MS) coupled with solid phase extraction (SPE). Water samples were extracted by SPE on a cartridge system containing C-18 as sorbent. To increase sensitivity and selectivity, OP was derivatized to 4-tert-octyl-phenoxy silane. With the use of phenanthrene-d10 as internal standard, the detection limit based on signal-to-noise ratio (S/N = 3) was 0.06 ng/mL. The average recovery was from 84.67% to 109.7%. The precision of the method given as the relative standard deviations (RSD) was within the range 6.24%-12.96%. In the target water samples, the concentrations of OP were as follows: 15.88-71.24 ng/L for Jinxiuchuan Reservoir, 3.850-26.68 ng/L for the city moat, 6.930-41.56 ng/L for Daming Lake, 66.03-474.2 ng/L for Xiaoqing River, 14.66-17.72 ng/L for the Yellow River, and 10.60-26.43 ng/L for Queshan Reservoir. The Xiaoqing River was seriously polluted due to the discharge of wastewater from Jinan. Jinxiuchuan Reservoir had a higher concentration of OP compared with the Yellow River and Queshan Reservoir, which is ascribed to the surrounding human activities. These data are reported for the first time, providing strong support for the control of OP pollution in Jinan.
Inferring the phase of the moon from the color of sunset
NASA Astrophysics Data System (ADS)
Thiermann, Ryan; Sweeney, Alison; Murugan, Arvind
We use information theory to investigate whether patterns in the spectral progression of twilight are informative of the lunar phase. Such optical cues have been sought to explain the synchronized spawning of corals and other biological processes that are coupled to the lunar cycle. We first quantify the maximum available information about lunar phase in twilight by combining measurements of twilight spectrum and models of spectral variations due to weather and atmospheric changes. We then quantify the biophysically accessible information by accounting for the spectral resolution of opsin proteins and the temporal resolution with which organisms can track spectral changes. We find that in most climates, relative spectral variation is a more reliable indicator of lunar phase than intensity variation alone since the former is less affected by cloud cover. We also find that organisms can extract most available information with three distinct opsins and reasonable integration times.
Surprises in low-dimensional correlated systems
NASA Astrophysics Data System (ADS)
Lin, Hsiu-Hau
In this thesis, correlation effects in low-dimensional systems were studied. In particular, we focus on two systems: a point-contact in the quantum-Hall regime under the influence of ac drive and quasi-one-dimensional ladder materials with generic interactions in weak coupling. Powerful techniques, including renormalization group, quantum field theory, operator product expansions, bosonization,...etc., were employed to extract surprising physics out of these strongly fluctuating systems. We first study the effect of an ac drive on the current-voltage (I-V) characteristics of a tunnel junction between two fractional Quantum Hall fluids at filling nu-1 an odd integer. In a semi-classical limit, the tunneling current exhibits mode-locking, which corresponds to plateaus in the I-V curve at integer multiples of I = ef , with f the ac drive frequency. However, the full quantum model exhibits rounded plateaus centered around the quantized current values due to quantum fluctuations. The locations of these plateaus can serve as an indirect hint of fractional charges. Switching attentions to quasi-one-dimensional coupled-chain systems, we present a systematic weak-coupling renormalization group (RG) technique and find that generally broad regions of the phase space of the ladder materials are unstable to pairing, usually with approximate d-wave symmetry. The dimensional crossovers from 1D to 2D were also discussed. Carbon nanotubes as possible candidates that display such unconventional pairing and interesting physics in weak coupling were discussed. Quite surprisingly, a hidden symmetry was found in the weakly-coupled two-leg ladder. A perturbative renormalization group analysis reveals that at half-filling the model scales onto an exactly soluble SO(8) symmetric Gross-Neveu model. Integrability of the Gross-Neveu model is employed to extract the exact energies, degeneracies and quantum numbers of all the low energy excited states, which fall into degenerate SO(8) multiplets. For generic physical interactions, there are four robust phases which have different SO(8) symmetries but share a common SO(5) symmetry. The effects of marginal chiral interactions were discussed at the end. Finally, we summarize our main results and discuss related open questions for future study.
Bomba, Francis Desire Tatsinkou; Wandji, Bibiane Aimee; Piegang, Basile Nganmegne; Awouafack, Maurice Ducret; Sriram, Dharmarajan; Yogeeswari, Perumal; Kamanyi, Albert; Nguelefack, Telesphore Benoit
2015-11-04
Aqueous maceration from the stem barks of Petersianthus macrocarpus (P. Beauv.) Liben (Lecythidaceae) is taken orally in the central Africa for the management of various ailments, including pain. This work was carried out to evaluate in mice, the antinociceptive effects of the aqueous and methanol extracts of the stem bark of P. macrocarpus. The chemical composition of the aqueous and methanol extracts prepared as cold macerations was determined by high performance liquid chromatography coupled with mass spectrometry (LCMS). The antinociceptive effects of these extracts administered orally at the doses of 100, 200 and 400 mg/kg were evaluated using behavioral pain model induced by acetic acid, formalin, hot-plate, capsaicin and glutamate. The rotarod test was also performed at the same doses. The oral acute toxicity of both extracts was studied at the doses of 800, 1600, 3200 and 6400 mg/kg in mice. The LCMS analysis revealed the presence of ellagic acid as the major constituent in the methanol extract. Both extracts of P. macrocarpus significantly and dose dependently reduced the time and number of writhing induced by acetic acid. They also significantly inhibited the two phases of formalin-induced pain. These effects were significantly inhibited by a pretreatment with naloxone, except for the analgesic activity of the methanol extract at the earlier phase. In addition, nociception induced by hot plate, intraplantar injection of capsaicin or glutamate was significantly inhibited by both extracts. Acute toxicity test showed no sign of toxicity. These results demonstrate that aqueous and methanol extracts of P. macrocarpus are none toxic substances with good central and peripheral antinociceptive effects that are at least partially due to the presence of ellagic acid. These extracts may induce their antinociceptive effect by interfering with opioid, capsaicin and excitatory amino acid pathways. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Interaction of charge carriers with lattice and molecular phonons in crystalline pentacene
NASA Astrophysics Data System (ADS)
Girlando, Alberto; Grisanti, Luca; Masino, Matteo; Brillante, Aldo; Della Valle, Raffaele G.; Venuti, Elisabetta
2011-08-01
The computational protocol we have developed for the calculation of local (Holstein) and non-local (Peierls) carrier-phonon coupling in molecular organic semiconductors is applied to both the low temperature and high temperature bulk crystalline phases of pentacene. The electronic structure is calculated by the semimpirical INDO/S (Intermediate Neglect of Differential Overlap with Spectroscopic parametrization) method. In the phonon description, the rigid molecule approximation is removed, allowing mixing of low-frequency intra-molecular modes with inter-molecular (lattice) phonons. A clear distinction remains between the low-frequency phonons, which essentially modulate the transfer integral from a molecule to another (Peierls coupling), and the high-frequency intra-molecular phonons, which modulate the on-site energy (Holstein coupling). The results of calculation agree well with the values extracted from experiment. The comparison with similar calculations made for rubrene allows us to discuss the implications for the current models of mobility.
Jones, Michael D; Avula, Bharathi; Wang, Yan-Hong; Lu, Lu; Zhao, Jianping; Avonto, Cristina; Isaac, Giorgis; Meeker, Larry; Yu, Kate; Legido-Quigley, Cristina; Smith, Norman; Khan, Ikhlas A
2014-10-17
Roman and German chamomile are widely used throughout the world. Chamomiles contain a wide variety of active constituents including sesquiterpene lactones. Various extraction techniques were performed on these two types of chamomile. A packed-column supercritical fluid chromatography-mass spectrometry method was designed for the identification of sesquiterpenes and other constituents from chamomile extracts with no derivatization step prior to analysis. Mass spectrometry detection was achieved by using electrospray ionization. All of the compounds of interest were separated within 15 min. The chamomile extracts were analyzed and compared for similarities and distinct differences. Multivariate statistical analysis including principal component analysis and orthogonal partial least squares-discriminant analysis (OPLS-DA) were used to differentiate between the chamomile samples. German chamomile samples confirmed the presence of cis- and trans-tonghaosu, chrysosplenols, apigenin diglucoside whereas Roman chamomile samples confirmed the presence of apigenin, nobilin, 1,10-epioxynobilin, and hydroxyisonobilin. Copyright © 2014 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Zhang, Benfeng; Han, Tao; Li, Xinyi; Huang, Yulin; Omori, Tatsuya; Hashimoto, Ken-ya
2018-07-01
This paper investigates how lateral propagation of Rayleigh and shear horizontal (SH) surface acoustic waves (SAWs) changes with rotation angle θ and SiO2 and electrode thicknesses, h SiO2 and h Cu, respectively. The extended thin plate model is used for purpose. First, the extraction method is presented for determining parameters appearing in the extended thin plate model. Then, the model parameters are expressed in polynomials in terms of h SiO2, h Cu, and θ. Finally, a piston mode structure without phase shifters is designed using the extracted parameters. The possible piston mode structures can be searched automatically by use of the polynomial expression. The resonance characteristics are analyzed by both the extended thin plate model and three-dimensional (3D) finite element method (FEM). Agreement between the results of both methods confirms validity and effectiveness of the parameter extraction process and the design technique.
Li, Yingguo; Chen, Yiqiang; Li, Zhengguo; Zhang, Lei; Li, Xianliang; Xi, Cunxian; Wang, Guomin; Wang, Xiong; Guo, Qi; Li, Na
2012-03-01
This paper describes the preparation of a novel mixed-bed immunoaffinity chromatography (IAC) column by coupling four monoclonal antibodies against different sulfonamides (SAs) to Sepharose 4B. The IAC column can be used to simultaneously extract and purify 16 SAs in pork muscle. The dynamic column capacities for all SAs in mixed standard solution were between 312 and 479 ng/mL gel. After simple extraction and IAC cleanup, the sample solution can be directly injected for liquid chromatography-ultraviolet analysis. The recoveries of SAs from spiked samples at levels of 25, 50 and 100 µg/kg ranged from 83.3 to 103.1% with variation coefficient less than 8.6%. The comparison of IAC with liquid-liquid extraction and solid phase extraction indicated that IAC has better purification effect and needs less organic solution than conventional methods, thus it would be an ideal method for selective purification of SAs in pork muscle.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Maddi, Balakrishna; Panisko, Ellen; Albrecht, Karl
Two-dimensional gas chromatography coupled with time of flight mass spectrometry is a powerful tool for identifying and quantifying components in complex mixtures. It has been used to analyze gasoline, jet fuel, diesel, bio-diesel and organic fraction of bio-crude/bio-oil. In these experiments, the first dimension of separation was non-polar, followed by a polar separation. Aqueous fractions of bio-crude and other aqueous samples have been examined with similar column combinations. However, sample preparation techniques such as derivatization, solvent extraction, and solid-phase extraction were necessary prior to analysis. In this study, aqueous fraction obtained from hydrothermal liquefaction of algae was characterized by two-dimensionalmore » gas chromatography coupled with time of flight mass spectrometry without prior sample preparation techniques using a polar separation in the first dimension followed by a non-polar separation. Two-dimensional plots from this analysis were compared with those obtained from the more traditional column combination. Results from qualitative characterization aqueous fractions of algal bio-crude are discussed in detail. The advantages of using a polar separation followed by a non-polar separation for characterization of organics in aqueous samples by two-dimensional gas chromatography coupled with time of flight mass spectrometry are highlighted.« less
Lamb wave extraction of dispersion curves in micro/nano-plates using couple stress theories
NASA Astrophysics Data System (ADS)
Ghodrati, Behnam; Yaghootian, Amin; Ghanbar Zadeh, Afshin; Mohammad-Sedighi, Hamid
2018-01-01
In this paper, Lamb wave propagation in a homogeneous and isotropic non-classical micro/nano-plates is investigated. To consider the effect of material microstructure on the wave propagation, three size-dependent models namely indeterminate-, modified- and consistent couple stress theories are used to extract the dispersion equations. In the mentioned theories, a parameter called 'characteristic length' is used to consider the size of material microstructure in the governing equations. To generalize the parametric studies and examine the effect of thickness, propagation wavelength, and characteristic length on the behavior of miniature plate structures, the governing equations are nondimensionalized by defining appropriate dimensionless parameters. Then the dispersion curves for phase and group velocities are plotted in terms of a wide frequency-thickness range to study the lamb waves propagation considering microstructure effects in very high frequencies. According to the illustrated results, it was observed that the couple stress theories in the Cosserat type material predict more rigidity than the classical theory; so that in a plate with constant thickness, by increasing the thickness to characteristic length ratio, the results approach to the classical theory, and by reducing this ratio, wave propagation speed in the plate is significantly increased. In addition, it is demonstrated that for high-frequency Lamb waves, it converges to dispersive Rayleigh wave velocity.
He, Jiao; Li, Jing; Sun, Wenji; Zhang, Tianyou; Ito, Yoichiro
2012-01-01
Coupled with evaporative light scattering detection, a high-speed counter-current chromatography (HSCCC) method was developed for preparative isolation and purification of three glycine-conjugated cholic acids, glycochenodeoxycholic acid (GCDCA), glycohyodeoxycholic acid (GHDCA) and glycohyocholic acid (GHCA) from Pulvis Fellis Suis (Pig gallbladder bile) for the first time. The separation was performed with a two-phase solvent system consisted of chloroform-methanol-water-acetic acid (65:30:10:1.5, v/v/v/v) by eluting the lower phase in the head-to-tail elution mode. The revolution speed of the separation column, flow rate of the mobile phase and separation temperature were 800 rpm, 2 ml/min and 25 °C, respectively. In a single operation, 33 mg of GCDCA, 38 mg of GHDCA and 23 mg of GHCA were obtained from 200 mg of crude extract with the purity of 95.65%, 96.72% and 96.63%, respectively, in one step separation. The HSCCC fractions were analyzed by high-performance liquid chromatography (HPLC) and the structures of the three glycine-conjugated cholic acids were identified by ESI-MS, (1)H NMR and (13)C NMR.
He, Jiao; Li, Jing; Sun, Wenji; Zhang, Tianyou; Ito, Yoichiro
2011-01-01
Coupled with evaporative light scattering detection, a high-speed counter-current chromatography (HSCCC) method was developed for preparative isolation and purification of three glycine-conjugated cholic acids, glycochenodeoxycholic acid (GCDCA), glycohyodeoxycholic acid (GHDCA) and glycohyocholic acid (GHCA) from Pulvis Fellis Suis (Pig gallbladder bile) for the first time. The separation was performed with a two-phase solvent system consisted of chloroform-methanol-water-acetic acid (65:30:10:1.5, v/v/v/v) by eluting the lower phase in the head-to-tail elution mode. The revolution speed of the separation column, flow rate of the mobile phase and separation temperature were 800 rpm, 2 ml/min and 25 °C, respectively. In a single operation, 33 mg of GCDCA, 38 mg of GHDCA and 23 mg of GHCA were obtained from 200 mg of crude extract with the purity of 95.65%, 96.72% and 96.63%, respectively, in one step separation. The HSCCC fractions were analyzed by high-performance liquid chromatography (HPLC) and the structures of the three glycine-conjugated cholic acids were identified by ESI-MS, 1H NMR and 13C NMR. PMID:23008527
Arain, Salma Aslam; Kazi, Tasneem G; Afridi, Hassan Imran; Abbasi, Abdul Rasool; Panhwar, Abdul Haleem; Naeemullah; Shanker, Bhawani; Arain, Mohammad Balal
2014-12-10
An efficient, innovative preconcentration method, dual-cloud point extraction (d-CPE) has been developed for the extraction and preconcentration of copper (Cu(2+)) in serum samples of different viral hepatitis patients prior to couple with flame atomic absorption spectrometry (FAAS). The d-CPE procedure was based on forming complexes of elemental ions with complexing reagent 1-(2-pyridylazo)-2-naphthol (PAN), and subsequent entrapping the complexes in nonionic surfactant (Triton X-114). Then the surfactant rich phase containing the metal complexes was treated with aqueous nitric acid solution, and metal ions were back extracted into the aqueous phase, as second cloud point extraction stage, and finally determined by flame atomic absorption spectrometry using conventional nebulization. The multivariate strategy was applied to estimate the optimum values of experimental variables for the recovery of Cu(2+) using d-CPE. In optimum experimental conditions, the limit of detection and the enrichment factor were 0.046μgL(-1) and 78, respectively. The validity and accuracy of proposed method were checked by analysis of Cu(2+) in certified sample of serum (CRM) by d-CPE and conventional CPE procedure on same CRM. The proposed method was successfully applied to the determination of Cu(2+) in serum samples of different viral hepatitis patients and healthy controls. Copyright © 2014 Elsevier B.V. All rights reserved.
Wang, Qiang; Zhu, Lingyan; Chen, Meng; Ma, Xinxin; Wang, Xiaolei; Xia, Junchao
2017-02-01
Bisphenol analogues are a group of chemicals which are being widely applied in industrial and household products owing to regulations on bisphenol A (BPA) in many countries. In this study, an analytical method, including extraction from complex environmental matrices, clean-up using solid phase extraction (SPE) and following-up derivatization prior to gas chromatography coupled with mass spectrometry (GC-MS), was developed to analyze seven commonly used bisphenols in sediment. Five kinds of extraction solvents, four kinds of SPE cartridges, and four kinds of SPE eluting solvents were individually tested for their performances; and the conditions for derivatizing were also optimized. Finally, C 18 cartridge was determined as the SPE cartridge and methanol was selected as extracting and eluting solvent. Acetic anhydride (AA) was used as derivatizing agent and reaction took 20 min at room temperature. The method was used successfully to measure the seven bisphenol compounds in sediment samples from Taihu Lake, China. BPA, bisphenol F and bisphenol S were detected in all sediment samples, with concentrations in the range of 3.94-33.2; 0.503-3.28 and 0.323-27.3 ng g -1 dw. Other compounds were detected at low frequencies or not detected. We provided a convenient, reliable, and sensitive method to analyze bisphenol compounds in complex environmental samples. Copyright © 2016 Elsevier Ltd. All rights reserved.
Campone, Luca; Piccinelli, Anna Lisa; Celano, Rita; Russo, Mariateresa; Valdés, Alberto; Ibáñez, Clara; Rastrelli, Luca
2015-04-01
According to current demands and future perspectives in food safety, this study reports a fast and fully automated analytical method for the simultaneous analysis of the mycotoxins with high toxicity and wide spread, aflatoxins (AFs) and ochratoxin A (OTA) in dried fruits, a high-risk foodstuff. The method is based on pressurized liquid extraction (PLE), with aqueous methanol (30%) at 110 °C, of the slurried dried fruit and online solid-phase extraction (online SPE) cleanup of the PLE extracts with a C18 cartridge. The purified sample was directly analysed by ultra-high-pressure liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) for sensitive and selective determination of AFs and OTA. The proposed analytical procedure was validated for different dried fruits (vine fruit, fig and apricot), providing method detection and quantification limits much lower than the AFs and OTA maximum levels imposed by EU regulation in dried fruit for direct human consumption. Also, recoveries (83-103%) and repeatability (RSD < 8, n = 3) meet the performance criteria required by EU regulation for the determination of the levels of mycotoxins in foodstuffs. The main advantage of the proposed method is full automation of the whole analytical procedure that reduces the time and cost of the analysis, sample manipulation and solvent consumption, enabling high-throughput analysis and highly accurate and precise results.
Pei, Miao; Huang, Xiaojia
2017-09-29
To extract tetracycline antibiotics (TAs) effectively, a new adsorbent based on poly (muconic acid-co-divinylbenzene/ethylenedimethacrylate) monolith was fabricated and used as the extraction medium of multiple monolithic fiber solid-phase microextraction (MD/MF-SPME). The effect of the fabrication parameters on extraction efficiency was studied thoroughly. Elemental analysis, infrared spectroscopy, scanning electron microscopy and mercury intrusion porosimetry were used to check the physicochemical properties of the adsorbent. Some key parameters that affect the extraction performance of MD/MF-SPME for TAs were investigated systematically. Under the optimized experimental conditions, the prepared adsorbent could effectively extract the TAs through multiple interactions. At the same time, a simple and sensitive method for monitoring trace TAs in honey samples was developed by coupling MD/MF-SPME with high-performance liquid chromatography tandem mass spectrometry detection (MD/MF-SPME-HPLC-MS/MS). The limits of detection (S/N=3) for target compounds were in the range of 7.3-17.1ng/kg. The intra-day and inter-day precision (relative standard deviations, n=4, %) at 0.5μg/kg and 20.0μg/kg spiking concentrations were 5.0-9.5% and 3.6-10.0%, respectively. The mean recoveries of the target TAs in the real honey samples were between 70.5-111.0%. Copyright © 2017 Elsevier B.V. All rights reserved.
Lambropoulou, Dimitra A; Konstantinou, Ioannis K; Albanis, Triantafyllos A
2006-07-28
In the present study a combined analytical method involving ultrasonic extraction (USE), sulfuric acid clean-up and headspace solid-phase microextraction (HS-SPME) was developed for the determination of chlorinated pesticides (CPs) in bird livers. Extraction of CPs from 1g of liver was performed by ultrasonication for 30 min using 20 mL of solvent mixture (n-hexane:acetone (4:1, v/v)). The extract was subsequently subjected to a clean-up step for lipid removal. A comparative study on several clean-up procedures prior to the HS-SPME enrichment step was performed in order to achieve maximum recovery and optimal clean-up efficiency, which would provide suitable limits of detection in the gas chromatographic analysis. For this purpose, destructive (sulfuric acid or sodium hydroxide treatment) and non-destructive (alumina column) clean-up procedures has been assayed. The treatment of the extract with 40% (v/v) H2SO4 prior to HS-SPME process showed the best performance since lower detection limits and higher extraction efficiencies were obtained. The method detection limit ranged from 0.5 to 1.0 ng g(-1) wet weight and peak areas were proportional to analyte concentrations (r2>0.990) in the range of 5-500 ng g(-1) wet wt. The method was found to be reproducible (R.S.D.<10%) and effective under the operational conditions proposed and was applied successfully to the analysis of CPs in liver tissues of various bird species from Greece.
Domingos Alves, Renata; Romero-González, Roberto; López-Ruiz, Rosalía; Jiménez-Medina, M L; Garrido Frenich, Antonia
2016-11-01
An analytical method based on a modified QuPPe (quick polar pesticide) extraction procedure coupled with liquid chromatography-tandem mass spectrometry (LC-MS/MS) was evaluated for the determination of four polar compounds (chlorate, fosetyl-Al, maleic hydrazide, and perchlorate) in nutraceutical products obtained from soy. Experimental conditions including extraction such as solvent, acidification, time, and clean-up sorbents were varied. Acidified acetonitrile (1 % formic acid, v/v) was used as extraction solvent instead of methanol (conventional QuPPe), which provides a doughy mixture which cannot be injected into the LC. Clean-up or derivatization steps were avoided. For analysis, several stationary phases were evaluated and Hypercarb (porous graphitic carbon) provided the best results. The optimized method was validated and recoveries ranged between 46 and 119 %, and correction factors can be used for quantification purposes bearing in mind that inter-day precision was equal to or lower than 17 %. Limits of quantification (LOQs) ranged from 4 to 100 μg kg -1 . Soy-based nutraceutical products were analyzed and chlorate was detected in five samples at concentrations between 63 and 1642 μg kg -1 . Graphical Abstract Analysis of polar compounds in soy-based nutraceutical products.
He, Xiaoqin; Xi, Cunxian; Tang, Bobin; Wang, Guomin; Chen, Dongdong; Peng, Tao; Mu, Zhaode
2014-01-01
A novel analytical method employing solid-phase extraction (SPE) coupled with ultra-high-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) was developed for the simultaneous determination of 30 hormones in anti-ageing functional foods (capsules, powders and tablets). The analytes were extracted with acetic acid-acetonitrile (1-99 v/v), methanol and acetone, respectively. The extract was purified using a combined column, followed by analyte detection with electrospray ionisation in positive- or negative-ion modes. The results indicated that the 30 compounds had good linear correlations in the range of 1-1000 μg kg⁻¹, and the correlation coefficients were above 0.99. The limits of detection (LOD) and limits of quantification (LOQ) were 0.03-2 and 0.1-5 μg kg⁻¹, respectively. The average recovery of 30 compounds at the three spiked levels varied from 74.7% to 124.1%, and the relative standard deviation (RSD) was 2.4-15.0%. This method was applied to the analysis of hormones in 14 real samples of which seven hormones (such as estrone, dienestrol) were detected in four samples, but the remainder of the hormones were not detected. The developed method is sensitive, efficient, reliable and applicable to real samples.
Lenkei, Z; Beaudet, A; Chartrel, N; De Mota, N; Irinopoulou, T; Braun, B; Vaudry, H; Llorens-Cortes, C
2000-11-01
Because G-protein-coupled receptors (GPCRs) constitute excellent putative therapeutic targets, functional characterization of orphan GPCRs through identification of their endogenous ligands has great potential for drug discovery. We propose here a novel single cell-based assay for identification of these ligands. This assay involves (a) fluorescent tagging of the GPCR, (b) expression of the tagged receptor in a heterologous expression system, (c) incubation of the transfected cells with fractions purified from tissue extracts, and (d) imaging of ligand-induced receptor internalization by confocal microscopy coupled to digital image quantification. We tested this approach in CHO cells stably expressing the NT1 neurotensin receptor fused to EGFP (enhanced green fluorescent protein), in which neurotensin promoted internalization of the NT1-EGFP receptor in a dose-dependent fashion (EC(50) = 0.98 nM). Similarly, four of 120 consecutive reversed-phase HPLC fractions of frog brain extracts promoted internalization of the NT1-EGFP receptor. The same four fractions selectively contained neurotensin, an endogenous ligand of the NT1 receptor, as detected by radioimmunoassay and inositol phosphate production. The present internalization assay provides a highly specific quantitative cytosensor technique with sensitivity in the nanomolar range that should prove useful for the identification of putative natural and synthetic ligands for GPCRs.
Guo, Y X; Han, J; Zhang, D Y; Wang, L H; Zhou, L L
2012-07-01
We studied the effect of ultrasonication extraction technology combined with ammonium sulfate/ethanol aqueous two-phase system (ATPS) for the separation of lithospermic acid B (LAB) from Salvia miltiorrhiza Bunge. According to the literature and preliminary studies, ammonium sulfate concentration, ethanol concentration, pH, ultrasonication power, ultrasonication time and the ratio of solvent-to-solid were investigated using a single factor design to identify the factors affecting separation. Taking into consideration a simultaneous increase in LAB recovery (R (%)) and partition coefficient (K), the best performance of the ATPS was obtained at 25°C and pH 2 using ammonium sulfate 22% (w/w) and ethanol 30% (w/w). To keep the solvent-to-solid ratio at 10, response surface methodology was used to find the optimal ultrasonication power and ultrasonication time. Quadratic models were predicted for LAB yield in the upper phase. Optimal conditions of 572.1 W ultrasonication power and 42.2 min produced a maximum yield of LAB of 42.16 mg g(-1) sample. There was no obvious degradation of LAB with ultrasound under the applied conditions, and the experimental yield of LAB was 42.49 mg g(-1) sample and the purity was 55.28% (w/w), which was much higher than that obtained using conventional extraction. The present study demonstrated that ultrasound coupled with aqueous two-phase systems is very efficient tool for the extraction and purification of LAB from Salvia miltiorrhiza Bunge. Copyright © 2011 Elsevier B.V. All rights reserved.
Mi, Jianing; Zhang, Min; Zhang, Hongyang; Wang, Yuerong; Wu, Shikun; Hu, Ping
2013-02-01
A high-efficient and environmental-friendly method for the preparation of ginsenosides from Radix Ginseng using the method of coupling of ultrasound-assisted extraction with expanded bed adsorption is described. Based on the optimal extraction conditions screened by surface response methodology, ginsenosides were extracted and adsorbed, then eluted by the two-step elution protocol. The comparison results between the coupling of ultrasound-assisted extraction with expanded bed adsorption method and conventional method showed that the former was better than the latter in both process efficiency and greenness. The process efficiency and energy efficiency of the coupling of ultrasound-assisted extraction with expanded bed adsorption method rapidly increased by 1.4-fold and 18.5-fold of the conventional method, while the environmental cost and CO(2) emission of the conventional method were 12.9-fold and 17.0-fold of the new method. Furthermore, the theoretical model for the extraction of targets was derived. The results revealed that the theoretical model suitably described the process of preparing ginsenosides by the coupling of ultrasound-assisted extraction with expanded bed adsorption system. © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Ding, X; Morrison, G; Dean, B; Hop, C E C A; Tobler, L; Percey, S; Meng, M; Reuschel, S; West, D A; Holden, S; Ware, J A
2012-03-05
A solid phase extraction (SPE) liquid chromatographic-tandem mass spectrometry (LC-MS/MS) method for the determination of GDC-0941 concentrations in human plasma has been developed and validated to support clinical development. An Oasis MCX 10mg 96-well SPE plate was used to extract plasma samples (50 μL) and the resulting extracts were analyzed using reverse-phase chromatography and mass spectrometer coupled with a turbo-ionspray interface. The method was validated over the calibration curve range 0.500-500 ng/mL with linear regression and 1/x(2) weighting. Within-run relative standard deviation (%RSD) ranged from 1.5 to 11.5%, while the between-run %RSD varied from 0.0 to 4.4%. The accuracy ranged from 96.0% to 110.0% of nominal for within-run and 98.0% to 108.0% of nominal for between-run at all concentrations including the LLOQ quality control at 0.500 ng/mL. Extraction recovery of GDC-0941 was between 79.0% and 86.2%. Stability of GDC-0941 was established in human plasma for 602 days at -70 °C and 598 days at -20°C, respectively, and established in reconstituted sample extracts for 167 h when stored at room temperature. Internal standard normalized matrix factor was 1.1, demonstrating that the use of the stable-labeled internal standard GDC-0941-d(8) effectively compensated observed matrix effect and resulting in no adverse impact on the quality of the data produced. This assay was used for the determination of GDC-0941 human plasma concentrations over a sufficient time period to determine pharmacokinetic parameters at relevant clinical doses. Copyright © 2011 Elsevier B.V. All rights reserved.
Feng, Shouai; Wei, Kang; Tian, Zhaofu; Li, Xiaolan; Meng, Dongling; Liao, Wenlong; Miao, Mingming; Yang, Yaling
2016-07-29
In this work, a simple and effective method based on magnetic solid-phase extraction combined with high-performance liquid chromatography was developed for the determination of benzo[α]pyrene (BaP) in cigarette smoke. Oleic acid coated Fe 3 O 4 (Fe 3 O 4 -OA) was synthesized and directly used as an efficient sorbent for the first time in magnetic solid-phase extraction (MSPE) procedure for the clean-up of BaP in cigarette smoke extracts. The synthesized Fe 3 O 4 -OA was characterized by transmission electron microscopy, X-ray diffraction and Fourier transformed infrared spectroscopy. The extraction via Fe 3 O 4 -OA was dispersed in the extracts of cigarette smoke followed by the magnetic isolation, acetonitrile-tetrahydrofuran (ACN-THF; v/v = 9:1) was used for desorption of the analyte. The effects of important parameters such as the amount of adsorbent, solution pH, the content of acetonitrile, temperature and sorption time were investigated. The method showed good linearity for the determination of BaP in the concentration range of 0.5-50 ng mL -1 with a regression coefficient (R 2 ) of 0.9987. The limit of detection and limit of quantification for BaP were obtained to be 0.12 and 0.41 ng mL -1 , respectively. The mean recoveries were in the range from 81.0% to 97.6% at low, medium, high spiked levels, and the relative standard deviations were in the range of 2.7-6.8%. Combined with high-performance liquid chromatography and fluorescence detection, a simple and effective method was developed for the analysis of BaP in cigarette smoke. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Ahmed, Trifa M; Lim, Hwanmi; Bergvall, Christoffer; Westerholm, Roger
2013-10-01
A multidimensional, on-line coupled liquid chromatographic/gas chromatographic system was developed for the quantification of polycyclic aromatic hydrocarbons (PAHs). A two-dimensional liquid chromatographic system (2D-liquid chromatography (LC)), with three columns having different selectivities, was connected on-line to a two-dimensional gas chromatographic system (2D-gas chromatography (GC)). Samples were cleaned up by combining normal elution and column back-flush of the LC columns to selectively remove matrix constituents and isolate well-defined, PAH enriched fractions. Using this system, the sequential removal of polar, mono/diaromatic, olefinic and alkane compounds from crude extracts was achieved. The LC/GC coupling was performed using a fused silica transfer line into a programmable temperature vaporizer (PTV) GC injector. Using the PTV in the solvent vent mode, excess solvent was removed and the enriched PAH sample extract was injected into the GC. The 2D-GC setup consisted of two capillary columns with different stationary phase selectivities. Heart-cutting of selected PAH compounds in the first GC column (first dimension) and transfer of these to the second GC column (second dimension) increased the baseline resolutions of closely eluting PAHs. The on-line system was validated using the standard reference materials SRM 1649a (urban dust) and SRM 1975 (diesel particulate extract). The PAH concentrations measured were comparable to the certified values and the fully automated LC/GC system performed the clean-up, separation and detection of PAHs in 16 extracts in less than 24 h. The multidimensional, on-line 2D-LC/2D-GC system eliminated manual handling of the sample extracts and minimised the risk of sample loss and contamination, while increasing accuracy and precision.
Lou, Chaoyan; Guo, Dandan; Zhang, Kai; Wu, Can; Zhang, Peimin; Zhu, Yan
2018-05-12
Phthalate esters (PAEs) are a group of serious environmental pollutants, which lead to carcinogenicity or tumorigenicity in human body. In this study, a rapid, sensitive and green method by graphene oxide coated hollow fiber membrane extraction (GO-HFME) coupled with supercritical fluid chromatography (SFC) was proposed for the determination of 11 phthalate esters in bottled beverages. Graphene oxide (GO) was prepared and coated onto a porous hollow fiber membrane (HFM) to reinforce the efficiency of membrane extraction. The modified hollow fiber membrane was employed for the extraction of phthalate esters from bottled beverages prior to the determination by the supercritical fluid chromatography with UV detection. To achieve the maximum extraction efficiency, several parameters were investigated including GO concentration, extraction time, desorption solution and desorption time. SFC variables including stationary phase, modifier composition and percentage, column temperature, flow rate and backpressure were studied to improve the separation conditions. Under these optimized conditions, all the studied 11 phthalate esters were well separated and simultaneously determined in 7 min by SFC. The performance of the developed method was evaluated. Good linearity was observed (R ≥ 0.999) in the range of 0.02-10.0 μg/mL with limit of detection (LOD, S/N = 3) ranging from 1.5 to 3.0 ng/mL. Recoveries of all the PAEs for the spiked samples were between 92.1% and 99.3% with satisfactory relative standard deviations (RSD) less than 5.9%. The proposed method is time-saving, green, simple and robust, which will be an alternative way to the analysis of PAEs in real samples. Copyright © 2018 Elsevier B.V. All rights reserved.
Zhang, Caixiang; Eganhouse, Robert P; Pontolillo, James; Cozzarelli, Isabelle M; Wang, Yanxin
2012-03-23
4-Nonylphenols (4-NPs) are known endocrine disruptors and by-products of the microbial degradation of nonylphenol polyethoxylate surfactants. One of the challenges to understanding the toxic effects of nonylphenols is the large number of isomers that may exist in environmental samples. In order to attribute toxic effects to specific compounds, a method is needed for the separation and quantitation of individual nonylphenol isomers. The pre-concentration methods of solvent sublimation, solid-phase extraction or liquid-liquid extraction prior to chromatographic analysis can be problematic because of co-extraction of thousands of compounds typically found in complex matrices such as municipal wastewater or landfill leachate. In the present study, steam distillation extraction (SDE) was found to be an effective pre-concentration method for extraction of 4-NPs from leachate and wastewater, and comprehensive two-dimensional gas chromatography (GC×GC) coupled with fast mass spectral data acquisition by time-of-flight mass spectrometry (ToFMS) enhanced the resolution and identification of 4-NP isomers. Concentrations of eight 4-NP isomers were determined in leachate from landfill cells of different age and wastewater influent and effluent samples. 4-NP isomers were about 3 times more abundant in leachate from the younger cell than the older one, whereas concentrations in wastewater effluent were either below detection limits or <1% of influent concentrations. 4-NP isomer distribution patterns were found to have been altered following release to the environment. This is believed to reflect isomer-specific degradation and accumulation of 4-NPs in the aquatic environment. Copyright © 2012 Elsevier B.V. All rights reserved.
Finding Major Patterns of Aging Process by Data Synchronization
NASA Astrophysics Data System (ADS)
Miyano, Takaya; Tsutsui, Takako
We developed a method for extracting feature patterns from multivariate data using a network of coupled phase oscillators subject to an analogue of the Kuramoto model for collective synchronization. Our method may be called data synchronization. We applied data synchronization to the care-needs-certification data, provided by Otsu City as a historical old city near Kyoto City, in the Japanese public long-term care insurance program to find the trend of the major patterns of the aging process for elderly people needing nursing care.
Abdulra'uf, Lukman Bola; Tan, Guan Huat
2013-12-15
Solid-phase microextraction (SPME) is a solvent-less sample preparation method which combines sample preparation, isolation, concentration and enrichment into one step. In this study, multivariate strategy was used to determine the significance of the factors affecting the solid phase microextraction of pesticide residues (fenobucarb, diazinon, chlorothalonil and chlorpyrifos) using a randomised factorial design. The interactions and effects of temperature, time and salt addition on the efficiency of the extraction of the pesticide residues were evaluated using 2(3) factorial designs. The analytes were extracted with 100 μm PDMS fibres according to the factorial design matrix and desorbed into a gas chromatography-mass spectrometry detector. The developed method was applied for the analysis of apple samples and the limits of detection were between 0.01 and 0.2 μg kg(-)(1), which were lower than the MRLs for apples. The relative standard deviations (RSD) were between 0.1% and 13.37% with average recovery of 80-105%. The linearity ranges from 0.5-50 μg kg(-)(1) with correlation coefficient greater than 0.99. Copyright © 2013 Elsevier Ltd. All rights reserved.
Fully 3D-Printed Preconcentrator for Selective Extraction of Trace Elements in Seawater.
Su, Cheng-Kuan; Peng, Pei-Jin; Sun, Yuh-Chang
2015-07-07
In this study, we used a stereolithographic 3D printing technique and polyacrylate polymers to manufacture a solid phase extraction preconcentrator for the selective extraction of trace elements and the removal of unwanted salt matrices, enabling accurate and rapid analyses of trace elements in seawater samples when combined with a quadrupole-based inductively coupled plasma mass spectrometer. To maximize the extraction efficiency, we evaluated the effect of filling the extraction channel with ordered cuboids to improve liquid mixing. Upon automation of the system and optimization of the method, the device allowed highly sensitive and interference-free determination of Mn, Ni, Zn, Cu, Cd, and Pb, with detection limits comparable with those of most conventional methods. The system's analytical reliability was further confirmed through analyses of reference materials and spike analyses of real seawater samples. This study suggests that 3D printing can be a powerful tool for building multilayer fluidic manipulation devices, simplifying the construction of complex experimental components, and facilitating the operation of sophisticated analytical procedures for most sample pretreatment applications.
Selective aqueous extraction of organics coupled with trapping by membrane separation
van Eikeren, Paul; Brose, Daniel J.; Ray, Roderick J.
1991-01-01
An improvement to processes for the selective extractation of organic solutes from organic solvents by water-based extractants is disclosed, the improvement comprising coupling various membrane separation processes with the organic extraction process, the membrane separation process being utilized to continuously recycle the water-based extractant and at the same time selectively remove or concentrate organic solute from the water-based extractant.
An Automated High-Throughput System to Fractionate Plant Natural Products for Drug Discovery
Tu, Ying; Jeffries, Cynthia; Ruan, Hong; Nelson, Cynthia; Smithson, David; Shelat, Anang A.; Brown, Kristin M.; Li, Xing-Cong; Hester, John P.; Smillie, Troy; Khan, Ikhlas A.; Walker, Larry; Guy, Kip; Yan, Bing
2010-01-01
The development of an automated, high-throughput fractionation procedure to prepare and analyze natural product libraries for drug discovery screening is described. Natural products obtained from plant materials worldwide were extracted and first prefractionated on polyamide solid-phase extraction cartridges to remove polyphenols, followed by high-throughput automated fractionation, drying, weighing, and reformatting for screening and storage. The analysis of fractions with UPLC coupled with MS, PDA and ELSD detectors provides information that facilitates characterization of compounds in active fractions. Screening of a portion of fractions yielded multiple assay-specific hits in several high-throughput cellular screening assays. This procedure modernizes the traditional natural product fractionation paradigm by seamlessly integrating automation, informatics, and multimodal analytical interrogation capabilities. PMID:20232897
Identifying and Quantifying Chemical Forms of Sediment-Bound Ferrous Iron.
NASA Astrophysics Data System (ADS)
Kohler, M.; Kent, D. B.; Bekins, B. A.; Cozzarelli, I.; Ng, G. H. C.
2015-12-01
Aqueous Fe(II) produced by dissimilatory iron reduction comprises only a small fraction of total biogenic Fe(II) within an aquifer. Most biogenic Fe(II) is bound to sediments on ion exchange sites; as surface complexes and, possibly, surface precipitates; or incorporated into solid phases (e.g., siderite, magnetite). Different chemical forms of sediment-bound Fe(II) have different reactivities (e.g., with dissolved oxygen) and their formation or destruction by sorption/desorption and precipitation/dissolution is coupled to different solutes (e.g., major cations, H+, carbonate). We are quantifying chemical forms of sediment-bound Fe(II) using previously published extractions, novel extractions, and experimental studies (e.g., Fe isotopic exchange). Sediments are from Bemidji, Minnesota, where biodegradation of hydrocarbons from a burst oil pipeline has driven extensive dissimilatory Fe(III) reduction, and sites potentially impacted by unconventional oil and gas development. Generally, minimal Fe(II) was mobilized from ion exchange sites (batch desorption with MgCl2 and repeated desorption with NH4Cl). A < 2mm sediment fraction from the iron-reducing zone at Bemidji had 1.8umol/g Fe(II) as surface complexes or carbonate phases (sodium acetate at pH 5) of which ca. 13% was present as surface complexes (FerroZine extractions). Total bioavailable Fe(III) and biogenic Fe(II) (HCl extractions) was 40-50 umole/g on both background and iron-reducing zone sediments . Approximately half of the HCl-extractable Fe from Fe-reducing zone sediments was Fe(II) whereas 12 - 15% of Fe extracted from background sediments was present as Fe(II). One-third to one-half of the total biogenic Fe(II) extracted from sediments collected from a Montana prairie pothole located downgradient from a produced-water disposal pit was present as surface-complexed Fe(II).
Wen, Qian; Wang, Yuzhi; Xu, Kaijia; Li, Na; Zhang, Hongmei; Yang, Qin
2016-10-05
A novel magnetic adsorbent, benzyl groups functionalized imidazolium-based polymeric ionic liquid (PIL)-coated magnetic multiwalled carbon nanotubes (MWCNTs) (m-MWCNTs@PIL), has been successfully synthesized and applied for the extraction of Cu, Zn-superoxide dismutase (Cu, Zn-SOD). The m-MWCNTs@PIL were characterized by X-ray diffraction (XRD), Fourier transform infrared spectrometry (FT-IR), thermal gravimetric analysis (TGA), field emission scanning electron microscopy (FESEM), vibrating sample magnetometer (VSM) and zeta-potential nanoparticles. In this method, the m-MWCNTs@PIL could interact with Cu, Zn-SOD through hydrogen bonding, π-π and electrostatic interactions. The extraction performance of the m-MWCNTs@PIL in the magnetic solid-phase extraction (MSPE) procedure was investigated, coupled with the determination by UV-vis spectrophotometer. Compared with m-MWCNTs@IL and m-MWCNTs, the m-MWCNTs@PIL exhibited the highest extraction capacity of 29.1 mg/g for Cu, Zn-SOD. The adsorbed Cu, Zn-SOD remained high specific activity after being eluted from m-MWCNTs@PIL by 1 moL/L NaCl solution. Besides, the m-MWCNTs@PIL could be easily recycled and successfully employed in the extraction of Cu, Zn-SOD from real samples. Under the optimal conditions, the precision, repeatability and stability of the proposed method were investigated and the RSDs were 0.29%, 1.68% and 0.54%, respectively. Recoveries were in the range of 82.7-102.3%, with the RSD between 3.47% and 5.35%. On the basis of these results, the developed method has great potential in the extraction of Cu, Zn-SOD or other analytes from biological samples. Copyright © 2016 Elsevier B.V. All rights reserved.
Zhang, Rong-Rong; Lu, Dan-Yi; Yang, Zhen-Ya; Zhao, Wen; But, Paul Pui-Hay; Shaw, Pang-Chui; Jiang, Ren-Wang; Ma, Zhi-Guo
2015-01-01
Background: Stemonae radix has been applied in traditional Chinese medicine for centuries. Alkaloids are the main active ingredient in stemonae radix, so their composition and concentration levels are directly linked to clinic effects. Objective: The objective was to develop an analytical method with multiple markers for quality survey of commercial stemonae radix. Materials and Methods: A method for simultaneous determination of six compounds in commercial stemonae radix was performed using solid-phase extraction and high-performance liquid chromatography coupled with evaporative light scattering detector. The separation was carried out on an Agilent TC-C18 column with 0.1% acetonitrile solution of triethylamine aqueous solution and acetonitrile as the mobile phase under gradient elution within 70 min. The hierarchical clustering analysis (HCA) was successfully used to classify the samples in accordance with their chemical constituents. Results: Linearity (R2 > 0.9990), intra- and inter-day precision (relative standard deviations <4%), limit of detection (0.011–0.086 μg/mL), limit of quantification (0.033–0.259 μg/mL) of the six alkaloids were determined, and the recoveries were between 96.6% and 103.7%. The method was successfully applied to analysis 36 batches of commercial stemonae radix. All the samples could be classified into five clusters by HCA. Conclusion: This article provides an accurate and simple analytical method for quality survey of commercial stemonae radix. Because of the significant chemical variations, careful selection of Stemona sources with obvious antitussive value but devoid of croomine followed by good agricultural practice and good manufacturing practice process is suggested. PMID:25829776
Bosch-Orea, Cristina; Sanchís, Josep; Farré, Marinella; Barceló, Damià
2017-09-01
Marine biotoxins regularly occur along the coast, with several consequences for the environment as well as the food industry. Monitoring of these compounds in seawater is required to assure the safety of marine resources for human consumption, providing a means for forecasting shellfish contamination events. In this study, an analytical method was developed for the detection of ten lipophilic marine biotoxins in seawater: azaspiracids 1, 2, 3, 4 and 5, classified as azaspiracid shellfish poisoning toxins, and pectenotoxin 2, okadaic acid and the related dinophysistoxin 1, yessotoxin and homoyessotoxin, classified as diarrheic shellfish poisoning toxins. The method is based on the application of solid-liquid ultrasound-assisted extraction and solid-phase extraction, followed by high-performance liquid chromatography coupled with high-resolution mass spectrometry. The limits of detection of this method are in the range of nanograms per litre and picograms per litre for most of the compounds, and recoveries range from 20.5% to 97.2%. To validate the effectiveness of this method, 36 samples of surface water from open coastal areas and marinas located along the Catalan coast on the Mediterranean Sea were collected and analysed. Eighty-eight per cent of these samples exhibited okadaic acid in particulate and aqueous phases in concentrations ranging from 0.11 to 560 μg/g and from 2.1 to 1780 ng/L respectively. Samples from open coastal areas exhibited higher concentrations of okadaic acid in particulate material, whereas in samples collected in sportive ports, the particulate material exhibited lower levels than the aqueous phase. Graphical Abstract Biotoxins investigated in seawater of the Catalan coast.
Lin, Yao; Yang, Yuan; Li, Yuxuan; Yang, Lu; Hou, Xiandeng; Feng, Xinbin; Zheng, Chengbin
2016-03-01
Rice consumption is a primary pathway for human methylmercury (MeHg) exposure in inland mercury mining areas of Asia. In addition, the use of iodomethane, a common fumigant that significantly accelerates the methylation of mercury in soil under sunlight, could increase the MeHg exposure from rice. Conventional hyphenated techniques used for mercury speciation analysis are usually too costly for most developing countries. Consequently, there is an increased interest in the development of sensitive and inexpensive methods for the speciation of mercury in rice. In this work, gas chromatography (GC) coupled to dielectric barrier discharge optical emission spectrometry (DBD-OES) was developed for the speciation analysis of mercury in rice. Prior to GC-DBD-OES analysis, mercury species were derivatized to their volatile species with NaBPh4 and preconcentrated by headspace solid phase microextraction using porous carbons. Limits of detection of 0.5 μg kg(-1) (0.16 ng), 0.75 μg kg(-1) (0.24 ng), and 1.0 μg kg(-1) (0.34 ng) were obtained for Hg(2+), CH3Hg(+), and CH3CH2Hg(+), respectively, with relative standard deviations (RSDs) better than 5.2% and 6.8% for one fiber or fiber-to-fiber mode, respectively. Recoveries of 90-105% were obtained for the rice samples, demonstrating the applicability of the proposed technique. Owing to the small size, low power, and low gas consumption of DBD-OES as well as efficient extraction of mercury species by porous carbons headspace solid phase micro-extraction, the proposed technique provides several advantages including compactness, cost-effectiveness, and potential to couple with miniature GC to accomplish the field speciation of mercury in rice compared to conventional hyphenated techniques.
Zhou, Jiezhao; Chen, Meiling; Li, Ying; Yu, Fanglin; Cheng, Xiaohui; Yang, Yang; Liu, Yan; Xie, Xiangyang; Li, Zhiping; Zhang, Hui; Mei, Xingguo
2017-10-01
Combination of metolazone (0.5 mg) and valsartan (80 mg) has been verified as a promising therapy treatment for hypertension. In order to facilitate to pharmacokinetic research, it needs a method for the simultaneously determination of metolazone and valsartan in biological samples. However, there are no relative reports so far. In order to facilitate to pharmacokinetic research, an on-line solid phase extraction coupled with liquid chromatography-tandem mass spectrometry method for the simultaneous determination of metolazone and valsartan in beagle dog plasma was developed and validated in this study. An on-line solid phase extraction column Retain PEP Javelin (10 mm × 2.1 mm) was used to remove impurities in plasma samples. The metolazone, valsartan and internal standard (losartan) were separated on a Poroshell 120 SB-C18 column (4.6 mm × 50 mm × 2.7 µm) with a gradient elution procedure. Acidified acetonitrile/water mixture was used as a mobile phase. The selected multiple-reaction monitoring mode in positive ion was performed and the parent to the product transitions m/z 366/259, m/z 436.2/291 and m/z 423.4/207 were used to measure the metolazone, valsartan and losartan. The method was linear over the range of 0.1-100 ng/mL and 1-1000 ng/mL for metolazone and valsartan, respectively. This method was validated in terms of specificity, linearity, sensitivity, precision, accuracy, matrix effect, and stability and then successfully applied to pharmacokinetic studies of the metolazone and valsartan combination tablets in beagle dogs.
Chen, YiQuan; Cheng, Xian; Mo, Fan; Huang, LiMei; Wu, Zujian; Wu, Yongning; Xu, LiangJun; Fu, FengFu
2016-04-01
A simple dispersive solid-phase extraction (DSPE) used to extract and preconcentrate ultra-trace MeHg, EtHg and Hg(2+) from water sample, and a sensitive method for the simultaneous analysis of MeHg, EtHg and Hg(2+) by using capillary electrophoresis-inductively coupled plasma mass spectrometry (CE-ICP-MS) with field-amplified sample stacking injection (FASI) were first reported in this study. The DSPE used thiol cotton particles as adsorbent, and is simple and effective. It can be used to extract and preconcentrate ultra-trace mercury compounds in water samples within 30 min with a satisfied recovery and no mercury species alteration during the process. The FASI enhanced the sensitivity of CE-ICP-MS with 25-fold, 29-fold and 27-fold for MeHg, EtHg and Hg(2+) , respectively. Using FASI-CE-ICP-MS together with DSPE, we have successfully determined ultra-trace MeHg, EtHg and Hg(2+) in tap water with a limits of quantification (LOQs) of 0.26-0.45 pg/mL, an RSD (n = 3) < 6% and a recovery of 92-108%. Ultra-high sensitivity, as well as much less sample and reagent consumption and low operating cost, make our method a valuable technique to the speciation analysis of ultra-trace mercury. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Zhou, Xiao-Xia; Lai, Yu-Jian; Liu, Rui; Li, Sha-Sha; Xu, Jing-Wen; Liu, Jing-Fu
2017-12-05
Efficient separation and preconcentration of trace nanoparticulate silver (NAg) from large-volume environmental waters is a prerequisite for reliable analysis and therefore understanding the environmental processes of silver nanoparticles (AgNPs). Herein, we report the novel use of polyvinylidene fluoride (PVDF) filter membrane for disk-based solid phase extraction (SPE) of NAg in 1 L of water samples with the disk-based SPE system, which consists of a syringe pump and a syringe filter holder to embed the filter membrane. While the PVDF membrane can selectively adsorb NAg in the presence of Ag + , aqueous solution of 2% (m/v) FL-70 is found to efficiently elute NAg. Analysis of NAg is performed following optimization of filter membrane and elution conditions with an enrichment factor of 1000. Additionally, transmission electron microscopy (TEM), UV-vis spectroscopy, and size-exclusion chromatography coupled with ICP-MS (SEC-ICP-MS) analysis showed that the extraction gives rise to no change in NAg size or shape, making this method attractive for practical applications. Furthermore, feasibility of the protocol is verified by applying it to extract NAg in four real waters with recoveries of 62.2-80.2% at 0.056-0.58 μg/L spiked levels. This work will facilitate robust studies of trace NAg transformation and their hazard assessments in the environment.
Lamas, J Pablo; Salgado-Petinal, Carmen; García-Jares, Carmen; Llompart, María; Cela, Rafael; Gómez, Mariano
2004-08-13
The continuous contamination of surface waters by pharmaceuticals is of most environmental concern. Selective serotonin reuptake inhibitors (SSRIs) are drugs currently prescribed for the treatment of depressions and other psychiatric disorders and then, they are among the pharmaceuticals that can occur in environmental waters. Solid-phase microextraction (SPME) coupled to gas chromatography-mass spectrometry has been applied to the extraction of five SSRIs--venlafaxine, fluvoxamine, fluoxetine, citalopram and sertraline--from water samples. Some of the analytes were not efficiently extracted as underivatized compounds and so, an in situ acetylation step was introduced in the sample preparation procedure. Different parameters affecting extraction efficiency such as extraction mode, fiber coating and temperature were studied. A mixed-level fractional factorial design was also performed to simultaneously study the influence of other five experimental factors. Finally, a method based on direct SPME at 100 degrees C using polydimethylsiloxane-divinylbenzene fibers is proposed. The performance of the method was evaluated, showing good linearity and precision. The detection limits were in the sub-ng/mL level. Practical applicability was demonstrated through the analysis of real samples. Recoveries obtained for river water and wastewater samples were satisfactory in all cases. An important aspect of the proposed method is that no matrix effects were observed. Two of the target compounds, venlafaxine and citalopram, were detected and quantified in a sewage water sample.
Yang, Yunjia; Yu, Jianlong; Yin, Jie; Shao, Bing; Zhang, Jing
2014-11-19
This study aimed to develop a selective analytical method for the simultaneous determination of seven bisphenol analogues in beverage and canned food samples by using a new molecularly imprinted polymer (MIP) as a sorbent for solid-phase extraction (SPE). Liquid chromatography coupled to triple-quadruple tandem mass spectrometry (LC-MS/MS) was used to identify and quantify the target analytes. The MIP-SPE method exhibited a higher level of selectivity and purification than the traditional SPE method. The developed procedures were further validated in terms of accuracy, precision, and sensitivity. The obtained recoveries varied from 50% to 103% at three fortification levels and yielded a relative standard deviation (RSD, %) of less than 15% for all of the analytes. The limits of quantification (LOQ) for the seven analytes varied from 0.002 to 0.15 ng/mL for beverage samples and from 0.03 to 1.5 ng/g for canned food samples. This method was used to analyze real samples that were collected from a supermarket in Beijing. Overall, the results revealed that bisphenol A and bisphenol F were the most frequently detected bisphenols in the beverage and canned food samples and that their concentrations were closely associated with the type of packaging material. This study provides an alternative method of traditional SPE extraction for screening bisphenol analogues in food matrices.
Experimental determination of the effective strong coupling constant
DOE Office of Scientific and Technical Information (OSTI.GOV)
Alexandre Deur; Volker Burkert; Jian-Ping Chen
2007-07-01
We extract an effective strong coupling constant from low Q{sup 2} data on the Bjorken sum. Using sum rules, we establish its Q{sup 2}-behavior over the complete Q{sup 2}-range. The result is compared to effective coupling constants extracted from different processes and to calculations based on Schwinger-Dyson equations, hadron spectroscopy or lattice QCD. Although the connection between the experimentally extracted effective coupling constant and the calculations is not clear, the results agree surprisingly well.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Agustsson, Ronald
In this project, RadiaBeam Technologies was tasked with developing a novel solution for a cost effective quench protection based on fast expansion of the normal zone. By inductively coupling a strong electromagnetic pulse via a resonant LC circuit, we attempted to demonstrate accelerated normal zone propagation. The AC field induces currents in the superconducting layer with the current density exceeding that of the critical current density, J c. This creates a large normal zone, uniformly distributing the dissipation through the magnet body. The method does not rely on thermal heating of the conductor, thus enabling nearly instantaneous protection. Through themore » course of the Phase II project, RadiaBeam Technologies continued extensive numerical modeling of the inductive quench system, re-designed and built several iterations of the POC system for testing and observed evidence of a transient partial quench being induced. However the final device was not fabricated. This was a consequence of the fundamentally complex nature of the energy extraction process and the challenges associated even with demonstrating the proof of concept in a bench top device.« less
NASA Technical Reports Server (NTRS)
Kleinman, Leonid S.; Reed, X. B., Jr.
1995-01-01
An algorithm has been developed for the forced convective diffusion-reaction problem for convection inside and outside a droplet by a recirculating flow field hydrodynamically coupled at the droplet interface with an external flow field that at infinity becomes a uniform streaming flow. The concentration field inside the droplet is likewise coupled with that outside by boundary conditions at the interface. A chemical reaction can take place either inside or outside the droplet or reactions can take place in both phases. The algorithm has been implemented and results are shown here for the case of no reaction and for the case of an external first order reaction, both for unsteady behavior. For pure interphase mass transfer, concentration isocontours, local and average Sherwood numbers, and average droplet concentrations have been obtained as a function of the physical properties and external flow field. For mass transfer enhanced by an external reaction, in addition to the above forms of results, we present the enhancement factor, with the results now also depending upon the (dimensionless) rate of reaction.
Su, Cheng-Kuan; Chen, Wei-Cheng
2018-04-25
To extend the applicability of solid phase extraction devices manufactured using 3D printing technologies, a stereolithographic 3D printer and resins incorporating titanium dioxide nanoparticles (TiO 2 NPs) were employed to fabricate a demountable minicolumn with TiO 2 NP-incorporated packing as a sample pretreatment device for the selective extraction of inorganic As and Se species from high-salt-content samples, and to facilitate their analyses when coupled to an inductively coupled plasma mass spectrometer. After optimization, the automatic system enabled highly sensitive determinations of As and Se species with detection limits as low as 0.004-0.033 μg L -1 for As and 0.061-0.128 μg L -1 for Se. Reliability was confirmed through analyses of the reference materials 1643f, SLEW-3, CASS-4, and 2670a, as well as spike analyses of samples of water and human urine. These 3D-printed minicolumns appear to be very useful for multi-elemental speciation of these elements from high-salt-content samples. Thus, the incorporation of active nanomaterials into raw printing resins can enable 3D printing technologies-not only to fabricate functionalized devices for diverse sample pretreatment applications but also to encourage the future development of multifunctional devices for analytical science. Graphical abstract Schematic presentation of a demountable minicolumn fabricated using a stereolithographic 3D printer and the resins incorporating with TiO 2 NPs. They were used to selectively extract As and Se species through controlling the sample acidities.
Hjelmeland, Anna K; Wylie, Philip L; Ebeler, Susan E
2016-02-01
Methoxypyrazines are volatile compounds found in plants, microbes, and insects that have potent vegetal and earthy aromas. With sensory detection thresholds in the low ng L(-1) range, modest concentrations of these compounds can profoundly impact the aroma quality of foods and beverages, and high levels can lead to consumer rejection. The wine industry routinely analyzes the most prevalent methoxypyrazine, 2-isobutyl-3-methoxypyrazine (IBMP), to aid in harvest decisions, since concentrations decrease during berry ripening. In addition to IBMP, three other methoxypyrazines IPMP (2-isopropyl-3-methoxypyrazine), SBMP (2-sec-butyl-3-methoxypyrazine), and EMP (2-ethyl-3-methoxypyrazine) have been identified in grapes and/or wine and can impact aroma quality. Despite their routine analysis in the wine industry (mostly IBMP), accurate methoxypyrazine quantitation is hindered by two major challenges: sensitivity and resolution. With extremely low sensory detection thresholds (~8-15 ng L(-1) in wine for IBMP), highly sensitive analytical methods to quantify methoxypyrazines at trace levels are necessary. Here we were able to achieve resolution of IBMP as well as IPMP, EMP, and SBMP from co-eluting compounds using one-dimensional chromatography coupled to positive chemical ionization tandem mass spectrometry. Three extraction techniques HS-SPME (headspace-solid phase microextraction), SBSE (stirbar sorptive extraction), and HSSE (headspace sorptive extraction) were validated and compared. A 30 min extraction time was used for HS-SPME and SBSE extraction techniques, while 120 min was necessary to achieve sufficient sensitivity for HSSE extractions. All extraction methods have limits of quantitation (LOQ) at or below 1 ng L(-1) for all four methoxypyrazines analyzed, i.e., LOQ's at or below reported sensory detection limits in wine. The method is high throughput, with resolution of all compounds possible with a relatively rapid 27 min GC oven program. Copyright © 2015 Elsevier B.V. All rights reserved.
Bellido-Martín, A; Gómez-Ariza, J L; Smichowsky, P; Sánchez-Rodas, D
2009-09-07
A fast extraction procedure has been developed for Sb(III) and Sb(V) oxoanions speciation in airborne particulate matter samples. Different extraction media (diammonium tartrate, hidroxilammonium clorhidrate, citric acid+ascorbic acid, phosphoric acid and citrate solutions) were tried, with assistance of an ultrasonic probe. The operation power and time of extraction were also optimized. The higher extraction recoveries were obtained with a 100 mmol L(-1) hidroxilammonium clorhidrate aqueous solution assisted by the ultrasound probe operated at 50 W during 3 min. The extracts were analyzed by HPLC-HG-AFS. The chromatographic separation of Sb(III) and Sb(V) was also optimized using diammonium tartrate and phthalic acid as mobile phases. The separation of both Sb species was performed in less than 3 min under isocratic conditions, using a 200 mmol L(-1) diammonium tartrate solution. The proposed extraction procedure and the HPLC-HG-AFS instrumental coupling have been successfully applied to airborne particulate matter samples, with high Sb content, collected in heavy traffic streets from Buenos Aires (Argentina). The results showed the presence of both Sb species at similar concentrations in the ng m(-3) level. The extraction yield was higher than 90% for all the analyzed samples.