Sample records for photometric titration procedure

  1. A Low-Cost Device for Automatic Photometric Titrations

    NASA Astrophysics Data System (ADS)

    Rocha, Fábio R. P.; Reis, Boaventura F.

    2000-02-01

    Electronics is an important topic in chemistry courses. However, the introduction of basic concepts is often difficult and the lab instruments are frequently seen as "black boxes". To address this problem, we propose the construction of a simple, low-cost (about $150 U.S.) automatic photometric titrator employing a light-emitting diode (LED) and a phototransistor. The electronic circuit can be assembled by the students themselves. The device was employed to implement a common procedure in chemical labs, making feasible the introduction of concepts related to electronics in undergraduate chemistry courses. The titrator is able to work automatically, since a feedback system permits stopping the addition of titrant solution when the end-point is achieved. With this demonstration, it can be stressed that automatic procedures can be implemented without expensive instruments. Additionally, a classical procedure becomes more attractive to the students and its importance to chemical analysis can be emphasized. The feasibility of the titrator was demonstrated by acid-base titrations of HCl solutions with NaOH in the presence of phenolphthalein and by iodimetric determination of ascorbic acid in vitamin C tablets and lemon juice. Precise results (0.7% relative standard deviation, n = 10) in agreement at the 95% confidence level with those attained by a conventional procedure were obtained.

  2. A Full Automatic Device for Sampling Small Solution Volumes in Photometric Titration Procedure Based on Multicommuted Flow System

    PubMed Central

    Borges, Sivanildo S.; Vieira, Gláucia P.; Reis, Boaventura F.

    2007-01-01

    In this work, an automatic device to deliver titrant solution into a titration chamber with the ability to determine the dispensed volume of solution, with good precision independent of both elapsed time and flow rate, is proposed. A glass tube maintained at the vertical position was employed as a container for the titrant solution. Electronic devices were coupled to the glass tube in order to control its filling with titrant solution, as well as the stepwise solution delivering into the titration chamber. The detection of the titration end point was performed employing a photometer designed using a green LED (λ=545 nm) and a phototransistor. The titration flow system comprised three-way solenoid valves, which were assembled to allow that the steps comprising the solution container loading and the titration run were carried out automatically. The device for the solution volume determination was designed employing an infrared LED (λ=930 nm) and a photodiode. When solution volume delivered from proposed device was within the range of 5 to 105 μl, a linear relationship (R = 0.999) between the delivered volumes and the generated potential difference was achieved. The usefulness of the proposed device was proved performing photometric titration of hydrochloric acid solution with a standardized sodium hydroxide solution and using phenolphthalein as an external indicator. The achieved results presented relative standard deviation of 1.5%. PMID:18317510

  3. Titrimetric and photometric methods for determination of hypochlorite in commercial bleaches.

    PubMed

    Jonnalagadda, Sreekanth B; Gengan, Prabhashini

    2010-01-01

    Two methods, simple titration and photometric methods for determination of hypochlorite are developed, based its reaction with hydrogen peroxide and titration of the residual peroxide by acidic permanganate. In the titration method, the residual hydrogen peroxide is estimated by titration with standard permanganate solution to estimate the hypochlorite concentration. The photometric method is devised to measure the concentration of remaining permanganate, after the reaction with residual hydrogen peroxide. It employs 4 ranges of calibration curves to enable the determination of hypochlorite accurately. The new photometric method measures hypochlorite in the range 1.90 x 10(-3) to 1.90 x 10(-2) M, with high accuracy and with low variance. The concentrations of hypochlorite in diverse commercial bleach samples and in seawater which is enriched with hypochlorite were estimated using the proposed method and compared with the arsenite method. The statistical analysis validates the superiority of the proposed method.

  4. GKI chloride in water, analysis method. GKI boron in water, analysis method

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Morriss, L.L.

    1979-05-01

    Procedures for the chemical analysis of chlorides and boron in water are presented. Chlorides can be titrated with mercuric nitrate to form mercuric chloride. At pH 2.3 to 2.8, diphenylcarbazone indicates the end point of this titration by formation of a purple complex with mercury ions. When a sample of water containing boron is acidified and evaporated in the presence of curcumin, a red colored product called rosocyanine is formed. This is dissolved and can be measured photometrically or visually. (DMC)

  5. Determination of polyhexamethylene biguanide hydrochloride using photometric colloidal titration with crystal violet as a color indicator.

    PubMed

    Masadome, Takashi; Miyanishi, Takaaki; Watanabe, Keita; Ueda, Hiroshi; Hattori, Toshiaki

    2011-01-01

    A solution of polyhexamethylene biguanide hydrochloride (PHMB-HCl) was titrated with a standard solution of potassium poly(vinyl sulfate) (PVSK) using crystal violet (CV) as an photometric indicator cation. The end point was detected by a sharp absorbance change due to an abrupt decrease in the concentration of CV. A linear relationship between the concentration of PHMB-HCl and the end-point volume of the titrant existed in the concentration range from 2 to 10 × 10(-6) eq mol L(-1). Back-titration was based on adding an excess amount of PVSK to a sample solution containing CV, which was titrated with a standard solution of poly(diallyldimethylammonium chloride) (PDADMAC). The calibration curve of the PHMB-HCl concentration to the end point volume of the titrant was also linear in the concentration range from 2 to 8 × 10(-6) eq mol L(-1). Both photometric titrations were applied to the determination of PHMB-HCl in a few contact-lens detergents. Back-titration showed a clear end point, but direct titration showed an unclear end point. The results of the back-titration of PHMB-HCl were compared with the content registered in its labels. 2011 © The Japan Society for Analytical Chemistry

  6. Determination of Titratable Acidity in Wine Using Potentiometric, Conductometric, and Photometric Methods

    ERIC Educational Resources Information Center

    Volmer, Dietrich A.; Curbani, Luana; Parker, Timothy A.; Garcia, Jennifer; Schultz, Linda D.; Borges, Endler Marcel

    2017-01-01

    This experiment describes a simple protocol for teaching acid-base titrations using potentiometry, conductivity, and/or photometry to determine end points without an added indicator. The chosen example examines the titratable acidity of a red wine with NaOH. Wines contain anthocyanins, the colors of which change with pH. Importantly, at the…

  7. Evaluation of the 5 and 8 pH point titration methods for monitoring anaerobic digesters treating solid waste.

    PubMed

    Vannecke, T P W; Lampens, D R A; Ekama, G A; Volcke, E I P

    2015-01-01

    Simple titration methods certainly deserve consideration for on-site routine monitoring of volatile fatty acid (VFA) concentration and alkalinity during anaerobic digestion (AD), because of their simplicity, speed and cost-effectiveness. In this study, the 5 and 8 pH point titration methods for measuring the VFA concentration and carbonate system alkalinity (H2CO3*-alkalinity) were assessed and compared. For this purpose, synthetic solutions with known H2CO3*-alkalinity and VFA concentration as well as samples from anaerobic digesters treating three different kind of solid wastes were analysed. The results of these two related titration methods were verified with photometric and high-pressure liquid chromatography measurements. It was shown that photometric measurements lead to overestimations of the VFA concentration in the case of coloured samples. In contrast, the 5 pH point titration method provides an accurate estimation of the VFA concentration, clearly corresponding with the true value. Concerning the H2CO3*-alkalinity, the most accurate and precise estimations, showing very similar results for repeated measurements, were obtained using the 8 pH point titration. Overall, it was concluded that the 5 pH point titration method is the preferred method for the practical monitoring of AD of solid wastes due to its robustness, cost efficiency and user-friendliness.

  8. Automatic photometric titrations of calcium and magnesium in carbonate rocks

    USGS Publications Warehouse

    Shapiro, L.; Brannock, W.W.

    1955-01-01

    Rapid nonsubjective methods have been developed for the determination of calcium and magnesium in carbonate rocks. From a single solution of the sample, calcium is titrated directly, and magnesium is titrated after a rapid removal of R2O3 and precipitation of calcium as the tungstate. A concentrated and a dilute solution of disodium ethylenediamine tetraacetate are used as titrants. The concentrated solution is added almost to the end point, then the weak solution is added in an automatic titrator to determine the end point precisely.

  9. [Photometric micro-titration model of DPPH radicals scavenging activity and its application].

    PubMed

    Gao, Yun-tao; Wei, Wei; Ye, Li-qing; Li, Xiao-fen; Liu, Ping; Zhang, Hong-jiao; Yang, Lu; Yu, Jiao-jiao; Cha, Jia-wei

    2015-02-01

    In the present paper, the stoichiometric ratio (R) for the interreaction of DPPH radicals with the antoxidant was employed as a evaluation index for DPPH radicals scavenging activity of antioxidants. This evaluation index was related only with the stoichiometric relationship between DPPH radicals and the antioxidant, not the relationship with the initial DPPH amount and the volume of sample, which could offer a solution for the problem of poor comparability of EC50 under different conditions. A novel photometric micro-titration method was proposed for the determination of the stoichiometric ratio (R) for the interreaction of DPPH radicals with the antoxidant. The titration equation was established based on the absorbance difference (deltaA) of DPPH radicals in the titration process and the added amount of antoxidant. The stoichiometric ratio (R) for the reaction of DPPH radicals with the addition amount of antoxidant was determined by the titration equation obtained, while, the DPPH median elimination concentration (EC50) of antoxidant can be calculated by the stoichiometric ratio (R). The above photometric micro-titration model was verified using rutin as DPPH radicals scavenger. As experiment results, the stoichiometric ratio (R) of DPPH radicals to rutin was determined to be in the range of 1.817-1.846. The calculated value of EC50 was 1.196 x 10(-3), 2.392 x 10(-3), 4.819 x 10(-3) and 7.292 x 10(-3) mg x mL(-1) for 1.12 x 10(-7), 2.24 x 10(-7), 4.48 x 10(-7) and 6.72 x 10(-7) mol of the additon amount of DPPH radicals, respectively. The proposed method has better precision and reliability with smaller amount of sample than conventional method. While, the obtained stoichiometric ratio value (R) of rutin was employed to calculate the rutin median elimination concentration for DPPH EC50) according to the conditions as reported in the literatures, and the calculated results were consistent with that reported in the literatures.

  10. Assembling and Using an LED-Based Detector to Monitor Absorbance Changes during Acid-Base Titrations

    ERIC Educational Resources Information Center

    Santos, Willy G.; Cavalheiro, E´der T. G.

    2015-01-01

    A simple photometric assembly based in an LED as a light source and a photodiode as a detector is proposed in order to follow the absorbance changes as a function of the titrant volume added during the course of acid-base titrations in the presence of a suitable visual indicator. The simplicity and low cost of the electronic device allow the…

  11. Developments in Titrimetry.

    ERIC Educational Resources Information Center

    Parry-Jones, R.

    1980-01-01

    Described are some new uses and procedures of titration procedures. Topics included are titration in non-aqueous solvents, thermometric titration and catalytic methods for end-point detection, titration finish in organic elemental analysis, and sub-micro analysis and automatic titration procedures. (CS)

  12. Comparison of VFA titration procedures used for monitoring the biogas process.

    PubMed

    Lützhøft, Hans-Christian Holten; Boe, Kanokwan; Fang, Cheng; Angelidaki, Irini

    2014-05-01

    Titrimetric determination of volatile fatty acids (VFAs) contents is a common way to monitor a biogas process. However, digested manure from co-digestion biogas plants has a complex matrix with high concentrations of interfering components, resulting in varying results when using different titration procedures. Currently, no standardized procedure is used and it is therefore difficult to compare the performance among plants. The aim of this study was to evaluate four titration procedures (for determination of VFA-levels of digested manure samples) and compare results with gas chromatographic (GC) analysis. Two of the procedures are commonly used in biogas plants and two are discussed in literature. The results showed that the optimal titration results were obtained when 40 mL of four times diluted digested manure was gently stirred (200 rpm). Results from samples with different VFA concentrations (1-11 g/L) showed linear correlation between titration results and GC measurements. However, determination of VFA by titration generally overestimated the VFA contents compared with GC measurements when samples had low VFA concentrations, i.e. around 1 g/L. The accuracy of titration increased when samples had high VFA concentrations, i.e. around 5 g/L. It was further found that the studied ionisable interfering components had lowest effect on titration when the sample had high VFA concentration. In contrast, bicarbonate, phosphate and lactate had significant effect on titration accuracy at low VFA concentration. An extended 5-point titration procedure with pH correction was best to handle interferences from bicarbonate, phosphate and lactate at low VFA concentrations. Contrary, the simplest titration procedure with only two pH end-points showed the highest accuracy among all titration procedures at high VFA concentrations. All in all, if the composition of the digested manure sample is not known, the procedure with only two pH end-points should be the procedure of choice, due to its simplicity and accuracy. Copyright © 2014 Elsevier Ltd. All rights reserved.

  13. Catalytic thermometric titrations in non-aqueous solvents by coulometrically generated titrant.

    PubMed

    Vajgand, V J; Gaál, F F; Brusin, S S

    1970-05-01

    Catalytic thermometric titrations have been developed for tertiary amines and salts of organic acids in acetic and propionic anhydride with titrant coulometrically generated at a mercury and/or platinum anode, hydroquinone being added to the solution titrated if the platinum anode is used. The results obtained are compared with those obtained by coulometric titration with the end-point detected either photometrically or potentiometrically. On a élaboré des titrages thermométriques catalytiques pour les amines tertiaires et les sels d'acides organiques en anhydrides aétique et propionique avec l'agent de titrage engendré coulométriquement sur une anode de mercure et/ou platine, de l'hydroquinone étant ajoutée à la solution titrée si l'on emploie l'anode de platine. Les résultats obtenus sont comparés avec ceux obtenus par titrage coulométrique avec le point de fin de réaction détecté soit photométriquement soit potentioétriquement.

  14. Scopolamine Effects Under a Titrating-Delayed-Nonmatching-to-Position Procedure

    ERIC Educational Resources Information Center

    Porritt, M.; Poling, A.

    2008-01-01

    In a study of working memory, the performance of rats under titrating-delayed-nonmatching- to-position (TDNMTP) procedures was examined. Overall accuracy and the number of trials completed were inversely related to titration value, whereas the highest delay attained was directly related to titration value. When given intraperitoneally,…

  15. [Determination of peracetic acid and hydrogen peroxide in a preparation].

    PubMed

    Bodiroga, Milanka; Ognjanović, Jasminka

    2002-01-01

    Iodometric and permanganometric titrations were used for determination of peracetic acid and hydrogen peroxide (H2O2) in the mixture. Two procedures were described and compared. Titrations could be done in only one vessel, in the same reaction mixture, when iodometric titration of peracetic acid was continued after the permanganometric titration of H2O2, (procedure A). Peracetic acid and H2O2, as oxidizing agents, reacted with potassium iodide in an acid medium, evolving iodine. This reaction was used for the quantitative iodometric determination of total peroxide in procedure B. H2O2 reacted with potassium permanganate in acid medium, but peracetic acid did not react under the same conditions. That made possible the selective permanganometric determination of H2O2 in the presence of peracetic acid. The procedure B was performed in two titration vessels (KV = 3.4% for peracetic acid, 0.6% for H2O2). The procedure A for iodometric determination of peracetic acid in one titration vessel after permanganometric titration of H2O2 was recommended (KV = 2.5% for peracetic acid, 0.45% for H2O2).

  16. Photometric method for determination of acidity constants through integral spectra analysis

    NASA Astrophysics Data System (ADS)

    Zevatskiy, Yuriy Eduardovich; Ruzanov, Daniil Olegovich; Samoylov, Denis Vladimirovich

    2015-04-01

    An express method for determination of acidity constants of organic acids, based on the analysis of the integral transmittance vs. pH dependence is developed. The integral value is registered as a photocurrent of photometric device simultaneously with potentiometric titration. The proposed method allows to obtain pKa using only simple and low-cost instrumentation. The optical part of the experimental setup has been optimized through the exclusion of the monochromator device. Thus it only takes 10-15 min to obtain one pKa value with the absolute error of less than 0.15 pH units. Application limitations and reliability of the method have been tested for a series of organic acids of various nature.

  17. Effects of Acute and Chronic Cocaine Administration on Titrating-Delay Matching-to-Sample Performance

    ERIC Educational Resources Information Center

    Kangas, Brian D.; Branch, Marc N.

    2012-01-01

    The effects of cocaine were examined under a titrating-delay matching-to-sample procedure. In this procedure, the delay between sample stimulus offset and comparison stimuli onset adjusts as a function of the subject's performance. Specifically, matches increase the delay and mismatches decrease the delay. Titrated delay values served as the…

  18. Homemade Equipment for the Teaching of Electrochemistry at Advanced Level: Part III.

    ERIC Educational Resources Information Center

    Chan, K. M.

    1985-01-01

    Describes: (1) thermometric titrations; (2) EM-5 equipment (consisting of a thermal sensor, calorimeter, and input-buffered amplifier); (3) acid-base titrations; (4) precipitation titrations; and (5) redox titrations. Detailed procedures are included. (JN)

  19. Photometric method for determination of acidity constants through integral spectra analysis.

    PubMed

    Zevatskiy, Yuriy Eduardovich; Ruzanov, Daniil Olegovich; Samoylov, Denis Vladimirovich

    2015-04-15

    An express method for determination of acidity constants of organic acids, based on the analysis of the integral transmittance vs. pH dependence is developed. The integral value is registered as a photocurrent of photometric device simultaneously with potentiometric titration. The proposed method allows to obtain pKa using only simple and low-cost instrumentation. The optical part of the experimental setup has been optimized through the exclusion of the monochromator device. Thus it only takes 10-15 min to obtain one pKa value with the absolute error of less than 0.15 pH units. Application limitations and reliability of the method have been tested for a series of organic acids of various nature. Copyright © 2015 Elsevier B.V. All rights reserved.

  20. Effects of ionic radius of redox-inactive bio-related metal ions on the radical-scavenging activity of flavonoids evaluated using photometric titration.

    PubMed

    Waki, Tsukasa; Kobayashi, Shigeki; Matsumoto, Ken-ichiro; Ozawa, Toshihiko; Kamada, Tadashi; Nakanishi, Ikuo

    2013-10-28

    Mg(2+) enhanced the scavenging activity of (+)-catechin and quercetin against the 2,2-diphenyl-1-picrylhydrazyl radical (DPPH˙), while Al(3+) decreased their activity. Such effects of Mg(2+) and Al(3+) were not observed for kaempferol. Na(+) and Ca(2+) with large ionic radii showed little effect on the DPPH˙-scavenging activity of these three flavonoids.

  1. Determination of quaternary ammonium compounds by potentiometric titration with an ionic surfactant electrode: single-laboratory validation.

    PubMed

    Price, Randi; Wan, Ping

    2010-01-01

    A potentiometric titration for determining the quaternary ammonium compounds (QAC) commonly found in antimicrobial products was validated by a single laboratory. Traditionally, QACs were determined by using a biphasic (chloroform and water) manual titration procedure. Because of safety considerations regarding chloroform, as well as the subjectivity of color indicator-based manual titration determinations, an automatic potentiometric titration procedure was tested with quaternary nitrogen product formulations. By using the Metrohm Titrando system coupled with an ionic surfactant electrode and an Ag/AgCl reference electrode, titrations were performed with various QAC-containing formulation products/matrixes; a standard sodium lauryl sulfate solution was used as the titrant. Results for the products tested are sufficiently reproducible and accurate for the purpose of regulatory product enforcement. The robustness of the method was measured by varying pH levels, as well as by comparing buffered versus unbuffered titration systems. A quantitation range of 1-1000 ppm quaternary nitrogen was established. Eight commercially available antimicrobial products covering a variety of matrixes were assayed; the results obtained were comparable to those obtained by the manual titration method. Recoveries of 94 to 104% were obtained for spiked samples.

  2. Asphalt compatibility testing using the automated Heithaus titration test

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pauli, A.T.

    1996-12-31

    The Heithaus titration test or variations of the test have been used for over 35 years to predict compatibilities of blends of asphalts from different crude sources. Asphalt compatibility is determined from three calculated parameters that measure the state of peptization of an asphalt or asphalt blend. The parameter p{sub a} is a measure of the peptizability of the asphaltenes. The parameter p{sub a} is a measure of the peptizing power of the maltenes, and the parameter P, derived from p{sub a} and p{sub o} values, is a measure of the overall state of peptization of the asphalt or asphaltmore » blend. In Heithaus original procedure, samples of asphalt were dissolved in toluene and titrated with n-heptane in order to initiate flocculation. The onset of flocculation was detected either by photography or by spotting a filter paper with a small amount of the titrated solution. Recently, an {open_quotes}automated{close_quotes} procedure, after Hotier and Robin, has been developed for use with asphalt. In the automated method UV-visible spectrophotometric detection measures the onset of flocculation as a peak with the percent transmittance plotted as a function of the volume of titrating solvent added to a solution of asphalt. The automated procedure has proven to be less operator dependent and much faster than the original Heithaus procedure. Results from the automated procedure show the data to be consistent with results from the original, {open_quotes}classical{close_quotes} Heithaus procedure.« less

  3. Spectrophotometric Titration of a Mixture of Calcium and Magnesium.

    ERIC Educational Resources Information Center

    Fulton, Robert; And Others

    1986-01-01

    Describes a spectrophotometric titration experiment which uses a manual titration spectrophotometer and manually operated buret, rather than special instrumentation. Identifies the equipment, materials, and procedures needed for the completion of the experiment. Recommends the use of this experiment in introductory quantitative analysis…

  4. pH Static Titration: A Quasistatic Approach

    ERIC Educational Resources Information Center

    Michalowski, Tadeusz; Toporek, Marcin; Rymanowski, Maciej

    2007-01-01

    The pH-static titration is applicable to those systems where at least two types of reactions occur in comparable intensities. The commonalities in titrimetric procedure realized according to pH-static titration, irrespective of the kind of chemical processes occurring are discussed.

  5. Acid-base properties of the alumina surface: influence of the titration procedures on the microcalorimetric results.

    PubMed

    Morel, Jean-Pierre; Marmier, Nicolas; Hurel, Charlotte; Morel-Desrosiers, Nicole

    2009-10-01

    The enthalpy changes associated with the protonation and deprotonation of an alumina surface have been determined on the basis of microcalorimetry experiments and acid-base potentiometric titrations at 25 degrees C. It has been shown that the results may vary significantly according to the experimental procedure. In order to do so, the potentiometric and microcalorimetric titrations have been carried out first from an acidic pH to basic pH and second from a pH near the pH(zpc) of alumina to acidic or basic pH. It has been demonstrated that the pK(a) values deduced from the potentiometric titrations are the same whatever the experimental protocol whereas the only way to obtain meaningful enthalpies of proton exchange is to carry out microcalorimetric titrations by starting around the point of zero charge.

  6. Ionization behavior of polyphosphoinositides determined via the preparation of pH titration curves using solid-state 31P NMR.

    PubMed

    Graber, Zachary T; Kooijman, Edgar E

    2013-01-01

    Detailed knowledge of the degree of ionization of lipid titratable groups is important for the evaluation of protein-lipid and lipid-lipid interactions. The degree of ionization is commonly evaluated by acid-base titration, but for lipids localized in a multicomponent membrane interface this is not a suitable technique. For phosphomonoester-containing lipids such as the polyphosphoinositides, phosphatidic acid, and ceramide-1-phosphate, this is more conveniently accomplished by (31)P NMR. Here, we describe a solid-state (31)P NMR procedure to construct pH titration curves to determine the degree of ionization of phosphomonoester groups in polyphosphoinositides. This procedure can also be used, with suitable sample preparation conditions, for other important signaling lipids. Access to a solid-state, i.e., magic angle spinning, capable NMR spectrometer is assumed. The procedures described here are valid for a Bruker instrument, but can be adapted for other spectrometers as needed.

  7. On the Photometric Calibration of FORS2 and the Sloan Digital Sky Survey

    NASA Astrophysics Data System (ADS)

    Bramich, D.; Moehler, S.; Coccato, L.; Freudling, W.; Garcia-Dabó, C. E.; Müller, P.; Saviane, I.

    2012-09-01

    An accurate absolute calibration of photometric data to place them on a standard magnitude scale is very important for many science goals. Absolute calibration requires the observation of photometric standard stars and analysis of the observations with an appropriate photometric model including all relevant effects. In the FORS Absolute Photometry (FAP) project, we have developed a standard star observing strategy and modelling procedure that enables calibration of science target photometry to better than 3% accuracy on photometrically stable nights given sufficient signal-to-noise. In the application of this photometric modelling to large photometric databases, we have investigated the Sloan Digital Sky Survey (SDSS) and found systematic trends in the published photometric data. The amplitudes of these trends are similar to the reported typical precision (˜1% and ˜2%) of the SDSS photometry in the griz- and u-bands, respectively.

  8. Estimation of uncertainty in pKa values determined by potentiometric titration.

    PubMed

    Koort, Eve; Herodes, Koit; Pihl, Viljar; Leito, Ivo

    2004-06-01

    A procedure is presented for estimation of uncertainty in measurement of the pK(a) of a weak acid by potentiometric titration. The procedure is based on the ISO GUM. The core of the procedure is a mathematical model that involves 40 input parameters. A novel approach is used for taking into account the purity of the acid, the impurities are not treated as inert compounds only, their possible acidic dissociation is also taken into account. Application to an example of practical pK(a) determination is presented. Altogether 67 different sources of uncertainty are identified and quantified within the example. The relative importance of different uncertainty sources is discussed. The most important source of uncertainty (with the experimental set-up of the example) is the uncertainty of pH measurement followed by the accuracy of the burette and the uncertainty of weighing. The procedure gives uncertainty separately for each point of the titration curve. The uncertainty depends on the amount of titrant added, being lowest in the central part of the titration curve. The possibilities of reducing the uncertainty and interpreting the drift of the pK(a) values obtained from the same curve are discussed.

  9. Going Beyond, Going Further: Knives, Forks, and Beer Cans as Potentiometric Sensors.

    ERIC Educational Resources Information Center

    Selig, Walter S.

    1985-01-01

    Background information, materials needed, and procedures used are provided for potentiometric fluoride, halide, orthophosphate, and sulfate titrations. Typical results obtained are also provided for each type of titration. (JN)

  10. Determination of nitrites in water by in-electrode coulometric titration in reticulated vitreous carbon electrode.

    PubMed

    Lenghartova, Katarina; Lauko, Lukas; Cachob, Frantisek; Beinrohr, Ernest

    2015-01-01

    Nitrite in water samples was determined by in-electrode coulometric titration in a reticulated vitreous carbon (RVC) electrode of 100 ppi porosity. The sample was mixed with dilute sulphuric acid and sodium sulphate, filled into a flow cell with the porous electrode and nitrite was oxidised to nitrate by constant current of 5 µA at which the potential of the electrode was monitored. The limits of detection and quantification were found to be 0.4 and 1.2 µg/L, respectively. The repeatability and reproducibility were 2.2 % and 2.6 %, respectively. The bias at 100 µg/L were found to be 0.3 %. The duration of the measurement is 2-3 min depending on the nitrite concentration. There were few interferences only, neutral and cationic surfactants decreased and increased slightly the signal, respectively. Humic acids above 30 mg/L increased the signal by 10 %. Drinking and surface water samples were analysed and the results matched well those from the photometric method.

  11. Determination of sulphite in wine by coulometric titration.

    PubMed

    Lowinsohn, D; Bertotti, M

    2001-09-01

    A method for the determination of both free and bound S(IV) in white wine samples by coulometric titration with electrogenerated iodine is described, the S(IV) speciation being performed by extracting SO2 from samples acidified wiith hydrochloric acid. Titrations of samples treated with NaOH led to the total S(IV) concentration, the results being in agreement with the ones obtained by the distillation procedure as well as by using the classical Monier-Williams method. An average recovery of 97% was obtained for samples spiked with S(IV) in the range 0.4-1.2 mM, which demonstrated the validity of the proposed procedure. The repeatability was 1.3% and the limit of detection was estimated as 0.01 mM. Results from direct titrations of wine added to the electrochemical cell are reported, which give indications of the stability of adducts towards the reaction with iodine.

  12. End-point detection in potentiometric titration by continuous wavelet transform.

    PubMed

    Jakubowska, Małgorzata; Baś, Bogusław; Kubiak, Władysław W

    2009-10-15

    The aim of this work was construction of the new wavelet function and verification that a continuous wavelet transform with a specially defined dedicated mother wavelet is a useful tool for precise detection of end-point in a potentiometric titration. The proposed algorithm does not require any initial information about the nature or the type of analyte and/or the shape of the titration curve. The signal imperfection, as well as random noise or spikes has no influence on the operation of the procedure. The optimization of the new algorithm was done using simulated curves and next experimental data were considered. In the case of well-shaped and noise-free titration data, the proposed method gives the same accuracy and precision as commonly used algorithms. But, in the case of noisy or badly shaped curves, the presented approach works good (relative error mainly below 2% and coefficients of variability below 5%) while traditional procedures fail. Therefore, the proposed algorithm may be useful in interpretation of the experimental data and also in automation of the typical titration analysis, specially in the case when random noise interfere with analytical signal.

  13. Spectroscopic studies on the interactions of 5-ethyl-6-phenyl-3,8-bis((3-aminoalkyl)propanamido)phenanthridin-5-ium derivatives with G-quadruplex DNA

    NASA Astrophysics Data System (ADS)

    Yalçın, Ergin; Duyar, Halil; Ihmels, Heiko; Seferoğlu, Zeynel

    2018-05-01

    An improved microwave-induced synthesis of five ethidium derivatives (Ethidium derivatives, 2a-d) is presented. As the derivatives 2a-d have been proposed previously to be telomerase inhibitors, the binding interactions of these ethidium derivatives with G-quadruplex DNA were evaluated by means of photometric and fluorimetric titration, thermal DNA denaturation, CD and 1H NMR spectroscopy. In particular, the compound bearing 3,8-bis(pyrrolidin-1-yl)propanamido substituent 2a exhibits high selectivity for G-quadruplex DNA relative to duplex DNA.

  14. Going Beyond, Going Further: The Preparation of Acid-Base Titration Curves.

    ERIC Educational Resources Information Center

    McClendon, Michael

    1984-01-01

    Background information, list of materials needed, and procedures used are provided for a simple technique for generating mechanically plotted acid-base titration curves. The method is suitable for second-year high school chemistry students. (JN)

  15. A new titration system of a novel split-type superconducting magnet NMR spectrometer.

    PubMed

    Kitagawa, Isao; Tanaka, Hideki; Okada, Michiya; Kitaguchi, Hitoshi; Kohzuma, Takamitsu

    2008-12-01

    A new titration system for studying protein-ligand interactions has been developed. In this system, the sample solution is circulated in the route formed by an access path in a split superconducting magnet to maintain a constant protein concentration during the titration experiments. A concentration-control procedure for the ligand/protein ratio is devised, and the ligand/protein ratio is well controlled by this apparatus.

  16. Four points function fitted and first derivative procedure for determining the end points in potentiometric titration curves: statistical analysis and method comparison.

    PubMed

    Kholeif, S A

    2001-06-01

    A new method that belongs to the differential category for determining the end points from potentiometric titration curves is presented. It uses a preprocess to find first derivative values by fitting four data points in and around the region of inflection to a non-linear function, and then locate the end point, usually as a maximum or minimum, using an inverse parabolic interpolation procedure that has an analytical solution. The behavior and accuracy of the sigmoid and cumulative non-linear functions used are investigated against three factors. A statistical evaluation of the new method using linear least-squares method validation and multifactor data analysis are covered. The new method is generally applied to symmetrical and unsymmetrical potentiometric titration curves, and the end point is calculated using numerical procedures only. It outperforms the "parent" regular differential method in almost all factors levels and gives accurate results comparable to the true or estimated true end points. Calculated end points from selected experimental titration curves compatible with the equivalence point category of methods, such as Gran or Fortuin, are also compared with the new method.

  17. Development and validation of a simplified titration method for monitoring volatile fatty acids in anaerobic digestion.

    PubMed

    Sun, Hao; Guo, Jianbin; Wu, Shubiao; Liu, Fang; Dong, Renjie

    2017-09-01

    The volatile fatty acids (VFAs) concentration has been considered as one of the most sensitive process performance indicators in anaerobic digestion (AD) process. However, the accurate determination of VFAs concentration in AD processes normally requires advanced equipment and complex pretreatment procedures. A simplified method with fewer sample pretreatment procedures and improved accuracy is greatly needed, particularly for on-site application. This report outlines improvements to the Nordmann method, one of the most popular titrations used for VFA monitoring. The influence of ion and solid interfering subsystems in titrated samples on results accuracy was discussed. The total solid content in titrated samples was the main factor affecting accuracy in VFA monitoring. Moreover, a high linear correlation was established between the total solids contents and VFA measurement differences between the traditional Nordmann equation and gas chromatography (GC). Accordingly, a simplified titration method was developed and validated using a semi-continuous experiment of chicken manure anaerobic digestion with various organic loading rates. The good fitting of the results obtained by this method in comparison with GC results strongly supported the potential application of this method to VFA monitoring. Copyright © 2017. Published by Elsevier Ltd.

  18. Acid Rain Analysis by Standard Addition Titration.

    ERIC Educational Resources Information Center

    Ophardt, Charles E.

    1985-01-01

    The standard addition titration is a precise and rapid method for the determination of the acidity in rain or snow samples. The method requires use of a standard buret, a pH meter, and Gran's plot to determine the equivalence point. Experimental procedures used and typical results obtained are presented. (JN)

  19. Determination of Acidity Constants by Gradient Flow-Injection Titration

    ERIC Educational Resources Information Center

    Conceicao, Antonio C. L.; Minas da Piedade, Manuel E.

    2006-01-01

    A three-hour laboratory experiment, designed for an advanced undergraduate course in instrumental analysis that illustrates the application of the gradient chamber flow-injection titration (GCFIT) method with spectrophotometric detection to determine acidity constants is presented. The procedure involves the use of an acid-base indicator to obtain…

  20. Coulometric Titration of Ethylenediaminetetraacetate (EDTA) with Spectrophotometric Endpoint Detection: An Experiment for the Instrumental Analysis Laboratory

    ERIC Educational Resources Information Center

    Williams, Kathryn R.; Young, Vaneica Y.; Killian, Benjamin J.

    2011-01-01

    Ethylenediaminetetraacetate (EDTA) is commonly used as an anticoagulant in blood-collection procedures. In this experiment for the instrumental analysis laboratory, students determine the quantity of EDTA in commercial collection tubes by coulometric titration with electrolytically generated Cu[superscript 2+]. The endpoint is detected…

  1. [Photometric determination of butyl "aeroflot" flotation agent (sodium dibutyl dithiophosphate) in the air of work zone and skin washings].

    PubMed

    Dorogova, V B; Kucheriavykh, E I; Sokolova, T V

    1989-01-01

    Photometric procedure of butyl "aeroflot" identification in the work zone air and in wash-out from workers' integument was developed, The procedure was based on the formation of yellow- and orange-dyed copper dibutyl dithiophosphate under butyl "aeroflot" interaction with copper sulphate with the subsequent photometry of dyed solutions for the wavelength of 420 nm in the 10-mm cell. Buffer solution with pH-9.2 was used as an absorbing solution for the workplace air sampling and integument wash-out.

  2. Tracer-monitored flow titrations.

    PubMed

    Sasaki, Milton K; Rocha, Diogo L; Rocha, Fábio R P; Zagatto, Elias A G

    2016-01-01

    The feasibility of implementing tracer-monitored titrations in a flow system is demonstrated. A dye tracer is used to estimate the instant sample and titrant volumetric fractions without the need for volume, mass or peak width measurements. The approach was applied to spectrophotometric flow titrations involving variations of sample and titrant flow-rates (i.e. triangle programmed technique) or concentration gradients established along the sample zone (i.e. flow injection system). Both strategies required simultaneous monitoring of two absorbing species, namely the titration indicator and the dye tracer. Mixing conditions were improved by placing a chamber with mechanical stirring in the analytical path aiming at to minimize diffusional effects. Unlike most of flow-based titrations, the innovation is considered as a true titration, as it does not require a calibration curve thus complying with IUPAC definition. As an application, acidity evaluation in vinegars involving titration with sodium hydroxide was selected. Phenolphthalein and brilliant blue FCF were used as indicator and dye tracer, respectively. Effects of sample volume, titrand/titrant concentrations and flow rates were investigated aiming at improved accuracy and precision. Results were reliable and in agreement with those obtained by a reference titration procedure. Copyright © 2015 Elsevier B.V. All rights reserved.

  3. Ion-selective electrodes in potentiometric titrations; a new method for processing and evaluating titration data.

    PubMed

    Granholm, Kim; Sokalski, Tomasz; Lewenstam, Andrzej; Ivaska, Ari

    2015-08-12

    A new method to convert the potential of an ion-selective electrode to concentration or activity in potentiometric titration is proposed. The advantage of this method is that the electrode standard potential and the slope of the calibration curve do not have to be known. Instead two activities on the titration curve have to be estimated e.g. the starting activity before the titration begins and the activity at the end of the titration in the presence of large excess of titrant. This new method is beneficial when the analyte is in a complexed matrix or in a harsh environment which affects the properties of the electrode and the traditional calibration procedure with standard solutions cannot be used. The new method was implemented both in a method of linearization based on the Grans's plot and in determination of the stability constant of a complex and the concentration of the complexing ligand in the sample. The new method gave accurate results when using titrations data from experiments with samples of known composition and with real industrial harsh black liquor sample. A complexometric titration model was also developed. Copyright © 2015 Elsevier B.V. All rights reserved.

  4. CALiPER Report 23: Photometric Testing of White Tunable LED Luminaires

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None, None

    2016-01-01

    This report documents an initial investigation of photometric testing procedures for white-tunable LED luminaires and summarizes the key features of those products. Goals of the study include understanding the amount of testing required to characterize a white-tunable product, and documenting the performance of available color-tunable luminaires that are intended for architectural lighting.

  5. Nutrigenomics, beta-cell function and type 2 diabetes.

    PubMed

    Nino-Fong, R; Collins, Tm; Chan, Cb

    2007-03-01

    The present investigation was designed to investigate the accuracy and precision of lactate measurement obtained with contemporary biosensors (Chiron Diagnostics, Nova Biomedical) and standard enzymatic photometric procedures (Sigma Diagnostics, Abbott Laboratories, Analyticon). Measurements were performed in vitro before and after the stepwise addition of 1 molar sodium lactate solution to samples of fresh frozen plasma to systematically achieve lactate concentrations of up to 20 mmol/l. Precision of the methods investigated varied between 1% and 7%, accuracy ranged between 2% and -33% with the variability being lowest in the Sigma photometric procedure (6%) and more than 13% in both biosensor methods. Biosensors for lactate measurement provide adequate accuracy in mean with the limitation of highly variable results. A true lactate value of 6 mmol/l was found to be presented between 4.4 and 7.6 mmol/l or even with higher difference. Biosensors and standard enzymatic photometric procedures are only limited comparable because the differences between paired determinations presented to be several mmol. The advantage of biosensors is the complete lack of preanalytical sample preparation which appeared to be the major limitation of standard photometry methods.

  6. The ASTRODEEP Frontier Fields catalogues. I. Multiwavelength photometry of Abell-2744 and MACS-J0416

    NASA Astrophysics Data System (ADS)

    Merlin, E.; Amorín, R.; Castellano, M.; Fontana, A.; Buitrago, F.; Dunlop, J. S.; Elbaz, D.; Boucaud, A.; Bourne, N.; Boutsia, K.; Brammer, G.; Bruce, V. A.; Capak, P.; Cappelluti, N.; Ciesla, L.; Comastri, A.; Cullen, F.; Derriere, S.; Faber, S. M.; Ferguson, H. C.; Giallongo, E.; Grazian, A.; Lotz, J.; Michałowski, M. J.; Paris, D.; Pentericci, L.; Pilo, S.; Santini, P.; Schreiber, C.; Shu, X.; Wang, T.

    2016-05-01

    Context. The Frontier Fields survey is a pioneering observational program aimed at collecting photometric data, both from space (Hubble Space Telescope and Spitzer Space Telescope) and from ground-based facilities (VLT Hawk-I), for six deep fields pointing at clusters of galaxies and six nearby deep parallel fields, in a wide range of passbands. The analysis of these data is a natural outcome of the Astrodeep project, an EU collaboration aimed at developing methods and tools for extragalactic photometry and creating valuable public photometric catalogues. Aims: We produce multiwavelength photometric catalogues (from B to 4.5 μm) for the first two of the Frontier Fields, Abell-2744 and MACS-J0416 (plus their parallel fields). Methods: To detect faint sources even in the central regions of the clusters, we develop a robust and repeatable procedure that uses the public codes Galapagos and Galfit to model and remove most of the light contribution from both the brightest cluster members, and the intra-cluster light. We perform the detection on the processed HST H160 image to obtain a pure H-selected sample, which is the primary catalogue that we publish. We also add a sample of sources which are undetected in the H160 image but appear on a stacked infrared image. Photometry on the other HST bands is obtained using SExtractor, again on processed images after the procedure for foreground light removal. Photometry on the Hawk-I and IRAC bands is obtained using our PSF-matching deconfusion code t-phot. A similar procedure, but without the need for the foreground light removal, is adopted for the Parallel fields. Results: The procedure of foreground light subtraction allows for the detection and the photometric measurements of ~2500 sources per field. We deliver and release complete photometric H-detected catalogues, with the addition of the complementary sample of infrared-detected sources. All objects have multiwavelength coverage including B to H HST bands, plus K-band from Hawk-I, and 3.6-4.5 μm from Spitzer. full and detailed treatment of photometric errors is included. We perform basic sanity checks on the reliability of our results. Conclusions: The multiwavelength photometric catalogues are available publicly and are ready to be used for scientific purposes. Our procedures allows for the detection of outshone objects near the bright galaxies, which, coupled with the magnification effect of the clusters, can reveal extremely faint high redshift sources. Full analysis on photometric redshifts is presented in Paper II. The catalogues, together with the final processed images for all HST bands (as well as some diagnostic data and images), are publicly available and can be downloaded from the Astrodeep website at http://www.astrodeep.eu/frontier-fields/ and from a dedicated CDS webpage (http://astrodeep.u-strasbg.fr/ff/index.html). The catalogues are also available at the CDS via anonymous ftp to http://cdsarc.u-strasbg.fr (http://130.79.128.5) or via http://cdsarc.u-strasbg.fr/viz-bin/qcat?J/A+A/590/A31

  7. Tested Demonstrations: Buffer Capacity of Various Acetic Acid-Sodium Acetate Systems: A Lecture Experiment.

    ERIC Educational Resources Information Center

    Donahue, Craig J.; Panek, Mary G.

    1985-01-01

    Background information and procedures are provided for a lecture experiment which uses indicators to illustrate the concept of differing buffer capacities by titrating acetic acid/sodium acetate buffers with 1.0 molar hydrochloric acid and 1.0 molar sodium hydroxide. A table with data used to plot the titration curve is included. (JN)

  8. Photometric microdetermination of malathion

    USGS Publications Warehouse

    Kallman, B.J.

    1962-01-01

    Carboxylic esters and lactones react with alkaline hydroxylamine to yield hydroxamates; these in acidic solution form colored iron(III) complexes. A photometric determination of such esters and lactones is thus permitted and has been extensively applied ( I-6). Hestrin ( 3) utilized this method for the microdetermination of acetylcholine and his procedure is much used for the in vitro study of cholinesterase activity and inhibition (4-6).

  9. Sensitivity of the acid-base properties of clays to the methods of preparation and measurement. 2. Evidence from continuous potentiometric titrations.

    PubMed

    Duc, Myriam; Gaboriaud, Fabien; Thomas, Fabien

    2005-09-01

    The effects of experimental procedures on the acid-base consumption titration curves of montmorillonite suspension were studied using continuous potentiometric titration. For that purpose, the hysteresis amplitudes between the acid and base branches were found to be useful to systematically evaluate the impacts of storage conditions (wet or dried), the atmosphere in titration reactor, the solid-liquid ratio, the time interval between successive increments, and the ionic strength. In the case of storage conditions, the increase of the hysteresis was significantly higher for longer storage of clay in suspension and drying procedures compared to "fresh" clay suspension. The titration carried out under air demonstrated carbonate contamination that could only be cancelled by performing experiments under inert gas. Interestingly, the increase of the time intervals between successive increments of titrant strongly emphasized the amplitude of hysteresis, which could be correlated with the slow kinetic process specifically observed for acid addition in acid media. Thus, such kinetic behavior is probably associated with dissolution processes of clay particles. However, the resulting curves recorded at different ionic strengths under optimized conditions did not show the common intersection point required to define point of zero charge. Nevertheless, the ionic strength dependence of the point of zero net proton charge suggested that the point of zero charge of sodic montmorillonite could be estimated as lower than 5.

  10. 3-D Surface Visualization of pH Titration "Topos": Equivalence Point Cliffs, Dilution Ramps, and Buffer Plateaus

    ERIC Educational Resources Information Center

    Smith, Garon C.; Hossain, Md Mainul; MacCarthy, Patrick

    2014-01-01

    3-D topographic surfaces ("topos") can be generated to visualize how pH behaves during titration and dilution procedures. The surfaces are constructed by plotting computed pH values above a composition grid with volume of base added in one direction and overall system dilution on the other. What emerge are surface features that…

  11. Correlation of surface enhanced Raman spectroscopy and nanoparticle aggregation with rhodamine 6G

    NASA Astrophysics Data System (ADS)

    Hoff, Christopher A.

    Surface enhanced Raman spectroscopy (SERS) has fascinated the analytical chemistry field for decades. The SERS phenomenon has progressively leveraged the inherently insensitive Raman phenomenon from a novelty vibrational spectroscopy method into one capable of single molecule detection, with attendant molecular level selectivity and information. Yet, even after 40 years since its discovery, the core mechanism behind this phenomenon is still debated. This thesis presents results from a series of photometric titrations wherein solutions of 30 nm Au@Ag nanoparticles (NPs) were titrated with rhodamine 6G (R6G), spanning five orders of magnitude in R6G concentration, and which elucidate the conditions required for the onset of SERS by R6G in this system. The experiments illustrated the correlation between the Raman response and the plasmonic (via UV-Vis spectroscopy) properties of the nanoparticle solutions. It was found that the onset of R6G SERS was related much more closely to the aggregation of the nanoparticles in solution than to their R6G adsorbed surface coverage. However, triggering aggregation with sodium chloride appeared to enhance SERS by an independent mechanism, which is operative only at low, i.e., [NaCl] > 100 mM concentration.

  12. 40 CFR 60.648 - Optional procedure for measuring hydrogen sulfide in acid gas-Tutwiler Procedure. 1

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... hydrogen sulfide in acid gas-Tutwiler Procedure. 1 60.648 Section 60.648 Protection of Environment... procedure for measuring hydrogen sulfide in acid gas—Tutwiler Procedure. 1 1 Gas Engineers Handbook, Fuel.... In principle, this method consists of titrating hydrogen sulfide in a gas sample directly with a...

  13. 40 CFR 60.648 - Optional procedure for measuring hydrogen sulfide in acid gas-Tutwiler Procedure. 1

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... hydrogen sulfide in acid gas-Tutwiler Procedure. 1 60.648 Section 60.648 Protection of Environment... procedure for measuring hydrogen sulfide in acid gas—Tutwiler Procedure. 1 1 Gas Engineers Handbook, Fuel.... In principle, this method consists of titrating hydrogen sulfide in a gas sample directly with a...

  14. 40 CFR 60.648 - Optional procedure for measuring hydrogen sulfide in acid gas-Tutwiler Procedure. 1

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... hydrogen sulfide in acid gas-Tutwiler Procedure. 1 60.648 Section 60.648 Protection of Environment..., 2011 § 60.648 Optional procedure for measuring hydrogen sulfide in acid gas—Tutwiler Procedure. 1 1 Gas... dilute solutions are used. In principle, this method consists of titrating hydrogen sulfide in a gas...

  15. 40 CFR 60.648 - Optional procedure for measuring hydrogen sulfide in acid gas-Tutwiler Procedure. 1

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... hydrogen sulfide in acid gas-Tutwiler Procedure. 1 60.648 Section 60.648 Protection of Environment... procedure for measuring hydrogen sulfide in acid gas—Tutwiler Procedure. 1 1 Gas Engineers Handbook, Fuel.... In principle, this method consists of titrating hydrogen sulfide in a gas sample directly with a...

  16. 40 CFR 60.5408 - What is an optional procedure for measuring hydrogen sulfide in acid gas-Tutwiler Procedure?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... measuring hydrogen sulfide in acid gas-Tutwiler Procedure? 60.5408 Section 60.5408 Protection of Environment... § 60.5408 What is an optional procedure for measuring hydrogen sulfide in acid gas—Tutwiler Procedure... of titrating hydrogen sulfide in a gas sample directly with a standard solution of iodine. (b...

  17. 40 CFR 60.5408 - What is an optional procedure for measuring hydrogen sulfide in acid gas-Tutwiler Procedure?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... measuring hydrogen sulfide in acid gas-Tutwiler Procedure? 60.5408 Section 60.5408 Protection of Environment... § 60.5408 What is an optional procedure for measuring hydrogen sulfide in acid gas—Tutwiler Procedure... of titrating hydrogen sulfide in a gas sample directly with a standard solution of iodine. (b...

  18. 40 CFR 60.648 - Optional procedure for measuring hydrogen sulfide in acid gas-Tutwiler Procedure. 1

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... hydrogen sulfide in acid gas-Tutwiler Procedure. 1 60.648 Section 60.648 Protection of Environment..., 2011 § 60.648 Optional procedure for measuring hydrogen sulfide in acid gas—Tutwiler Procedure. 1 1 Gas... dilute solutions are used. In principle, this method consists of titrating hydrogen sulfide in a gas...

  19. Cooperative photometric redshift estimation

    NASA Astrophysics Data System (ADS)

    Cavuoti, S.; Tortora, C.; Brescia, M.; Longo, G.; Radovich, M.; Napolitano, N. R.; Amaro, V.; Vellucci, C.

    2017-06-01

    In the modern galaxy surveys photometric redshifts play a central role in a broad range of studies, from gravitational lensing and dark matter distribution to galaxy evolution. Using a dataset of ~ 25,000 galaxies from the second data release of the Kilo Degree Survey (KiDS) we obtain photometric redshifts with five different methods: (i) Random forest, (ii) Multi Layer Perceptron with Quasi Newton Algorithm, (iii) Multi Layer Perceptron with an optimization network based on the Levenberg-Marquardt learning rule, (iv) the Bayesian Photometric Redshift model (or BPZ) and (v) a classical SED template fitting procedure (Le Phare). We show how SED fitting techniques could provide useful information on the galaxy spectral type which can be used to improve the capability of machine learning methods constraining systematic errors and reduce the occurrence of catastrophic outliers. We use such classification to train specialized regression estimators, by demonstrating that such hybrid approach, involving SED fitting and machine learning in a single collaborative framework, is capable to improve the overall prediction accuracy of photometric redshifts.

  20. Standardization and validation of a new atomic absorption spectroscopy technique for determination and quantitation of aluminium adjuvant in immunobiologicals.

    PubMed

    Mishra, Arti; Bhalla, Sumir Rai; Rawat, Sameera; Bansal, Vivek; Sehgal, Rakesh; Kumar, Sunil

    2007-10-01

    In the present study, Aluminium quantification in immunobiologicals has been described using atomic absorption spectroscopy (AAS) technique. The assay was found to be linear in 25-125 microg/ml Aluminium range. The procedure was found to be accurate for different vaccines with recoveries of external additions ranging between 93.26 and 103.41%. The mean Limit of Variation (L.V.) for both intra- and inter-assay precision was calculated to be 1.62 and 2.22%, respectively. Further the procedure was found to be robust in relation to digestion temperature, alteration in acid (HNO(3) and H(2)SO(4)) ratio used for sample digestion and storage of digested vaccine samples up to a period of 15 days. After validation, AAS method was compared for its equivalency with routinely used complexometric titration method. On simultaneously applying on seven different groups of both bacterial and viral vaccines, viz., DPT, DT, TT, Hepatitis-A and B, Antirabies vaccine (cell culture) and tetravalent DPT-Hib, a high degree of positive correlation (+0.85-0.998) among AAS and titration methods was observed. Further AAS method was found to have an edge over complexometric titration method that a group of vaccines, viz., ARV (cell culture, adsorbed) and Hepatitis-A, in which Aluminium estimation is not feasible by pharmacopoeial approved complexometric titration method (possibly due to some interference in the sample matrix), this newly described and validated AAS assay procedure delivered accurate and reproducible results.

  1. Improving Photometric Calibration of Meteor Video Camera Systems

    NASA Technical Reports Server (NTRS)

    Ehlert, Steven; Kingery, Aaron; Cooke, William

    2016-01-01

    Current optical observations of meteors are commonly limited by systematic uncertainties in photometric calibration at the level of approximately 0.5 mag or higher. Future improvements to meteor ablation models, luminous efficiency models, or emission spectra will hinge on new camera systems and techniques that significantly reduce calibration uncertainties and can reliably perform absolute photometric measurements of meteors. In this talk we discuss the algorithms and tests that NASA's Meteoroid Environment Office (MEO) has developed to better calibrate photometric measurements for the existing All-Sky and Wide-Field video camera networks as well as for a newly deployed four-camera system for measuring meteor colors in Johnson-Cousins BV RI filters. In particular we will emphasize how the MEO has been able to address two long-standing concerns with the traditional procedure, discussed in more detail below.

  2. Systemic errors in quantitative polymerase chain reaction titration of self-complementary adeno-associated viral vectors and improved alternative methods.

    PubMed

    Fagone, Paolo; Wright, J Fraser; Nathwani, Amit C; Nienhuis, Arthur W; Davidoff, Andrew M; Gray, John T

    2012-02-01

    Self-complementary AAV (scAAV) vector genomes contain a covalently closed hairpin derived from a mutated inverted terminal repeat that connects the two monomer single-stranded genomes into a head-to-head or tail-to-tail dimer. We found that during quantitative PCR (qPCR) this structure inhibits the amplification of proximal amplicons and causes the systemic underreporting of copy number by as much as 10-fold. We show that cleavage of scAAV vector genomes with restriction endonuclease to liberate amplicons from the covalently closed terminal hairpin restores quantitative amplification, and we implement this procedure in a simple, modified qPCR titration method for scAAV vectors. In addition, we developed and present an AAV genome titration procedure based on gel electrophoresis that requires minimal sample processing and has low interassay variability, and as such is well suited for the rigorous quality control demands of clinical vector production facilities.

  3. Comparative study of procedures for the analysis of chloride in hardened concrete.

    DOT National Transportation Integrated Search

    1976-01-01

    In the widely used potentiometric titration procedure for the analysis of chloride in powdered hardened concrete samples, difficulties have often been encountered when determining the endpoint. These difficulties have been eliminated through the use ...

  4. Initiation of Levodopa-Carbidopa Intestinal Gel Infusion Using Telemedicine (Video Communication System) Facilitates Efficient and Well-Accepted Home Titration in Patients with Advanced Parkinson's Disease.

    PubMed

    Willows, Thomas; Dizdar, Nil; Nyholm, Dag; Widner, Håkan; Grenholm, Peter; Schmiauke, Ursula; Urbom, Anna; Groth, Kristina; Larsson, Jörgen; Permert, Johan; Kjellander, Susanna

    2017-01-01

    Levodopa-carbidopa intestinal gel (LCIG; Duodopa®) is used for continuous infusion in advanced Parkinson's disease. To achieve optimal effect, the LCIG dose is individually titrated, traditionally conducted during hospitalization in Sweden. However, dose adjustment depends on surrounding conditions, physical activity, and emotional stress, which is why titration at home could be beneficial. Telemedicine (TM) using a video communication system offers alternative titration procedures, allowing LCIG initiation at home. Study objectives were to show the feasibility of TM for LCIG home titration, evaluate resource use, and assess patient, neurologist, and nurse satisfaction. Four clinics enrolled 15 patients to observe efficiency and feasibility of TM-based monitoring. Patient median (range) age was 67 (52-73) years and time since diagnosis was 10 (7-23) years. Median time between LCIG initiation and end of TM-assisted titration was 2.8 (2.0-13.8) days. Median time required for home titration by neurologists, nurses, and patients was (hours:minutes) 1 : 14 (0 : 29-1 : 52), 5 : 49 (2 : 46-10 : 3), and 8 : 53 (4 : 11-14 : 11), respectively. Neurologists and nurses considered this to be less time than required for hospital titration. TM allowed patients 92% free time from start to end of titration. Technical problems associated with TM contacts were rare, mostly related to digital link, and quickly resolved. Patients, neurologists, and nurses were satisfied using TM. No serious adverse events were reported; there was one device complaint (tube occlusion). In this study, TM-assisted LCIG titration at home was resource-efficient, technically feasible, well-accepted and was deemed satisfactory by patients, neurologists, and nurses.

  5. Analysis of Aircraft Fuels and Related Materials

    DTIC Science & Technology

    1982-09-01

    content by the Karl Fischer method . Each 2040 solvent sample represented a different step in a clean-up procedure conducted by Aero Propulsion...izes a potentiometric titration with alcoholic silver nitrate. This method has a minimum detectability of 1 ppm. It has a re- peatability of 0.1 ppm... Method 163-80, which util- izes a potentiometric titration with alcoholic silver nitrate. This method has a minimum detectability of 1 ppm and has a

  6. NICOLAU: compact unit for photometric characterization of automotive lighting from near-field measurements

    NASA Astrophysics Data System (ADS)

    Royo, Santiago; Arranz, Maria J.; Arasa, Josep; Cattoen, Michel; Bosch, Thierry

    2005-02-01

    The present works depicts a measurement technique intended to enhance the characterization procedures of the photometric emissions of automotive headlamps, with potential applications to any light source emission, either automotive or non-automotive. A CCD array with a precisely characterized optical system is used for sampling the luminance field of the headlamp just a few centimetres in front of it, by combining deflectometric techniques (yielding the direction of the light beams) and photometric techniques (yielding the energy travelling in each direction). The CCD array scans the measurement plane using a self-developed mechanical unit and electronics, and then image-processing techniques are used for obtaining the photometric behaviour of the headlamp in any given plane, in particular in the plane and positions required by current normative, but also on the road, on traffic signs, etc. An overview of the construction of the system, of the considered principle of measurement, and of the main calibrations performed on the unit is presented. First results concerning relative measurements are presented compared both to reference data from a photometric tunnel and from a plane placed 5m away from the source. Preliminary results for the absolute photometric calibration of the system are also presented for different illumination beams of different headlamps (driving and passing beam).

  7. Cross-correlation redshift calibration without spectroscopic calibration samples in DES Science Verification Data

    NASA Astrophysics Data System (ADS)

    Davis, C.; Rozo, E.; Roodman, A.; Alarcon, A.; Cawthon, R.; Gatti, M.; Lin, H.; Miquel, R.; Rykoff, E. S.; Troxel, M. A.; Vielzeuf, P.; Abbott, T. M. C.; Abdalla, F. B.; Allam, S.; Annis, J.; Bechtol, K.; Benoit-Lévy, A.; Bertin, E.; Brooks, D.; Buckley-Geer, E.; Burke, D. L.; Carnero Rosell, A.; Carrasco Kind, M.; Carretero, J.; Castander, F. J.; Crocce, M.; Cunha, C. E.; D'Andrea, C. B.; da Costa, L. N.; Desai, S.; Diehl, H. T.; Doel, P.; Drlica-Wagner, A.; Fausti Neto, A.; Flaugher, B.; Fosalba, P.; Frieman, J.; García-Bellido, J.; Gaztanaga, E.; Gerdes, D. W.; Giannantonio, T.; Gruen, D.; Gruendl, R. A.; Gutierrez, G.; Honscheid, K.; Jain, B.; James, D. J.; Jeltema, T.; Krause, E.; Kuehn, K.; Kuhlmann, S.; Kuropatkin, N.; Lahav, O.; Li, T. S.; Lima, M.; March, M.; Marshall, J. L.; Martini, P.; Melchior, P.; Ogando, R. L. C.; Plazas, A. A.; Romer, A. K.; Sanchez, E.; Scarpine, V.; Schindler, R.; Schubnell, M.; Sevilla-Noarbe, I.; Smith, M.; Soares-Santos, M.; Sobreira, F.; Suchyta, E.; Swanson, M. E. C.; Tarle, G.; Thomas, D.; Vikram, V.; Walker, A. R.; Wechsler, R. H.

    2018-06-01

    Galaxy cross-correlations with high-fidelity redshift samples hold the potential to precisely calibrate systematic photometric redshift uncertainties arising from the unavailability of complete and representative training and validation samples of galaxies. However, application of this technique in the Dark Energy Survey (DES) is hampered by the relatively low number density, small area, and modest redshift overlap between photometric and spectroscopic samples. We propose instead using photometric catalogues with reliable photometric redshifts for photo-z calibration via cross-correlations. We verify the viability of our proposal using redMaPPer clusters from the Sloan Digital Sky Survey (SDSS) to successfully recover the redshift distribution of SDSS spectroscopic galaxies. We demonstrate how to combine photo-z with cross-correlation data to calibrate photometric redshift biases while marginalizing over possible clustering bias evolution in either the calibration or unknown photometric samples. We apply our method to DES Science Verification (DES SV) data in order to constrain the photometric redshift distribution of a galaxy sample selected for weak lensing studies, constraining the mean of the tomographic redshift distributions to a statistical uncertainty of Δz ˜ ±0.01. We forecast that our proposal can, in principle, control photometric redshift uncertainties in DES weak lensing experiments at a level near the intrinsic statistical noise of the experiment over the range of redshifts where redMaPPer clusters are available. Our results provide strong motivation to launch a programme to fully characterize the systematic errors from bias evolution and photo-z shapes in our calibration procedure.

  8. Cross-correlation redshift calibration without spectroscopic calibration samples in DES Science Verification Data

    DOE PAGES

    Davis, C.; Rozo, E.; Roodman, A.; ...

    2018-03-26

    Galaxy cross-correlations with high-fidelity redshift samples hold the potential to precisely calibrate systematic photometric redshift uncertainties arising from the unavailability of complete and representative training and validation samples of galaxies. However, application of this technique in the Dark Energy Survey (DES) is hampered by the relatively low number density, small area, and modest redshift overlap between photometric and spectroscopic samples. We propose instead using photometric catalogs with reliable photometric redshifts for photo-z calibration via cross-correlations. We verify the viability of our proposal using redMaPPer clusters from the Sloan Digital Sky Survey (SDSS) to successfully recover the redshift distribution of SDSS spectroscopic galaxies. We demonstrate how to combine photo-z with cross-correlation data to calibrate photometric redshift biases while marginalizing over possible clustering bias evolution in either the calibration or unknown photometric samples. We apply our method to DES Science Verification (DES SV) data in order to constrain the photometric redshift distribution of a galaxy sample selected for weak lensing studies, constraining the mean of the tomographic redshift distributions to a statistical uncertainty ofmore » $$\\Delta z \\sim \\pm 0.01$$. We forecast that our proposal can in principle control photometric redshift uncertainties in DES weak lensing experiments at a level near the intrinsic statistical noise of the experiment over the range of redshifts where redMaPPer clusters are available. Here, our results provide strong motivation to launch a program to fully characterize the systematic errors from bias evolution and photo-z shapes in our calibration procedure.« less

  9. Cross-correlation redshift calibration without spectroscopic calibration samples in DES Science Verification Data

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Davis, C.; Rozo, E.; Roodman, A.

    Galaxy cross-correlations with high-fidelity redshift samples hold the potential to precisely calibrate systematic photometric redshift uncertainties arising from the unavailability of complete and representative training and validation samples of galaxies. However, application of this technique in the Dark Energy Survey (DES) is hampered by the relatively low number density, small area, and modest redshift overlap between photometric and spectroscopic samples. We propose instead using photometric catalogs with reliable photometric redshifts for photo-z calibration via cross-correlations. We verify the viability of our proposal using redMaPPer clusters from the Sloan Digital Sky Survey (SDSS) to successfully recover the redshift distribution of SDSS spectroscopic galaxies. We demonstrate how to combine photo-z with cross-correlation data to calibrate photometric redshift biases while marginalizing over possible clustering bias evolution in either the calibration or unknown photometric samples. We apply our method to DES Science Verification (DES SV) data in order to constrain the photometric redshift distribution of a galaxy sample selected for weak lensing studies, constraining the mean of the tomographic redshift distributions to a statistical uncertainty ofmore » $$\\Delta z \\sim \\pm 0.01$$. We forecast that our proposal can in principle control photometric redshift uncertainties in DES weak lensing experiments at a level near the intrinsic statistical noise of the experiment over the range of redshifts where redMaPPer clusters are available. Here, our results provide strong motivation to launch a program to fully characterize the systematic errors from bias evolution and photo-z shapes in our calibration procedure.« less

  10. Detoxification with titration and tapering in gamma-hydroxybutyrate (GHB) dependent patients: The Dutch GHB monitor project.

    PubMed

    Dijkstra, Boukje A G; Kamal, Rama; van Noorden, Martijn S; de Haan, Hein; Loonen, Anton J M; De Jong, Cor A J

    2017-01-01

    Gamma-hydroxybutyrate (GHB) detoxification procedures have been insufficiently studied for effectiveness and safety. Based on case reports, benzodiazepines are generally regarded as first-choice agents in GHB detoxification. Detoxification by titration and tapering (DeTiTap) with pharmaceutical GHB in an open-label consecutive case series of 23 GHB-dependent patients showed to be feasible, effective and safe. This study further explored the feasibility, effectiveness and safety of this detoxification procedure in a large group of patients. A large observational multicenter study was carried out in six addiction treatment centers in the Netherlands. GHB-dependent inpatients (229 unique patients, 274 admissions) were titrated on and tapered off with pharmaceutical GHB. Successful detoxification was achieved in 85% of cases. Detoxification was carried out in 12.5days in most patients. The DeTiTap procedure proved to be feasible and significantly reduced the experienced withdrawal symptoms and craving (p≤0.001). Several symptoms were found to influence the course of subjective withdrawal symptoms. During detoxification, psychological symptoms such as depression, anxiety, and stress decreased (p≤0.05). The main complications were hypertension and anxiety. Six patients were sent to the general hospital for observation, but all six were able to continue detoxification in the addiction treatment centers. Most patients (69%) relapsed within three months after detoxification. The DeTiTap procedure using pharmaceutical GHB seems a safe alternative to benzodiazepines as a GHB detoxification procedure. However, the high relapse rates warrant further investigation. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  11. ASSESSMENT OF ATTENTION THRESHOLD IN RATS BY TITRATION OF VISUAL CUE DURATION DURING THE FIVE CHOICE SERIAL REACTION TIME TASK

    PubMed Central

    Martin, Thomas J.; Grigg, Amanda; Kim, Susy A.; Ririe, Douglas G.; Eisenach, James C.

    2014-01-01

    Background The 5 choice serial reaction time task (5CSRTT) is commonly used to assess attention in rodents. We sought to develop a variant of the 5CSRTT that would speed training to objective success criteria, and to test whether this variant could determine attention capability in each subject. New Method Fisher 344 rats were trained to perform a variant of the 5CSRTT in which the duration of visual cue presentation (cue duration) was titrated between trials based upon performance. The cue duration was decreased when the subject made a correct response, or increased with incorrect responses or omissions. Additionally, test day challenges were provided consisting of lengthening the intertrial interval and inclusion of a visual distracting stimulus. Results Rats readily titrated the cue duration to less than 1 sec in 25 training sessions or less (mean ± SEM, 22.9 ± 0.7), and the median cue duration (MCD) was calculated as a measure of attention threshold. Increasing the intertrial interval increased premature responses, decreased the number of trials completed, and increased the MCD. Decreasing the intertrial interval and time allotted for consuming the food reward demonstrated that a minimum of 3.5 sec is required for rats to consume two food pellets and successfully attend to the next trial. Visual distraction in the form of a 3 Hz flashing light increased the MCD and both premature and time out responses. Comparison with existing method The titration variant of the 5CSRTT is a useful method that dynamically measures attention threshold across a wide range of subject performance, and significantly decreases the time required for training. Task challenges produce similar effects in the titration method as reported for the classical procedure. Conclusions The titration 5CSRTT method is an efficient training procedure for assessing attention and can be utilized to assess the limit in performance ability across subjects and various schedule manipulations. PMID:25528113

  12. Potentiometric/turbidometric titration of antiperspirant actives.

    PubMed

    Johnston, Clifford T; Hem, Stanley L; Guenin, Eric; Mattai, Jairajh; Afflito, John

    2003-01-01

    A titration procedure that simultaneously monitors the pH and turbidity of an antiperspirant solution during neutralization with sodium hydroxide was developed to characterize antiperspirant actives. Aluminum chloride, aluminum chlorohydrate (ACH), and aluminum zirconium glycine complex (AZG) gave distinctive pH/turbidity profiles. The activated forms of aluminum chlorohydrate (ACH') and aluminum zirconium glycine complex (AZG') produced more turbidity than the non-activated forms. On an equimolar basis, AZG' produced more turbidity than any of the antiperspirant actives tested.

  13. Novel approaches to analysis by flow injection gradient titration.

    PubMed

    Wójtowicz, Marzena; Kozak, Joanna; Kościelniak, Paweł

    2007-09-26

    Two novel procedures for flow injection gradient titration with the use of a single stock standard solution are proposed. In the multi-point single-line (MP-SL) method the calibration graph is constructed on the basis of a set of standard solutions, which are generated in a standard reservoir and subsequently injected into the titrant. According to the single-point multi-line (SP-ML) procedure the standard solution and a sample are injected into the titrant stream from four loops of different capacities, hence four calibration graphs are able to be constructed and the analytical result is calculated on the basis of a generalized slope of these graphs. Both approaches have been tested on the example of spectrophotometric acid-base titration of hydrochloric and acetic acids with using bromothymol blue and phenolphthalein as indicators, respectively, and sodium hydroxide as a titrant. Under optimized experimental conditions the analytical results of precision less than 1.8 and 2.5% (RSD) and of accuracy less than 3.0 and 5.4% (relative error (RE)) were obtained for MP-SL and SP-ML procedures, respectively, in ranges of 0.0031-0.0631 mol L(-1) for samples of hydrochloric acid and of 0.1680-1.7600 mol L(-1) for samples of acetic acid. The feasibility of both methods was illustrated by applying them to the total acidity determination in vinegar samples with precision lower than 0.5 and 2.9% (RSD) for MP-SL and SP-ML procedures, respectively.

  14. Evaluation on the use of cerium in the NBL Titrimetric Method

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zebrowski, J.P.; Orlowicz, G.J.; Johnson, K.D.

    An alternative to potassium dichromate as titrant in the New Brunswick Laboratory Titrimetric Method for uranium analysis was sought since chromium in the waste makes disposal difficult. Substitution of a ceric-based titrant was statistically evaluated. Analysis of the data indicated statistically equivalent precisions for the two methods, but a significant overall bias of +0.035% for the ceric titrant procedure. The cause of the bias was investigated, alterations to the procedure were made, and a second statistical study was performed. This second study revealed no statistically significant bias, nor any analyst-to-analyst variation in the ceric titration procedure. A statistically significant day-to-daymore » variation was detected, but this was physically small (0.01 5%) and was only detected because of the within-day precision of the method. The added mean and standard deviation of the %RD for a single measurement was found to be 0.031%. A comparison with quality control blind dichromate titration data again indicated similar overall precision. Effects of ten elements on the ceric titration`s performance was determined. Co, Ti, Cu, Ni, Na, Mg, Gd, Zn, Cd, and Cr in previous work at NBL these impurities did not interfere with the potassium dichromate titrant. This study indicated similar results for the ceric titrant, with the exception of Ti. All the elements (excluding Ti and Cr), caused no statistically significant bias in uranium measurements at levels of 10 mg impurity per 20-40 mg uranium. The presence of Ti was found to cause a bias of {minus}0.05%; this is attributed to the presence of sulfate ions, resulting in precipitation of titanium sulfate and occlusion of uranium. A negative bias of 0.012% was also statistically observed in the samples containing chromium impurities.« less

  15. Initiation of Levodopa-Carbidopa Intestinal Gel Infusion Using Telemedicine (Video Communication System) Facilitates Efficient and Well-Accepted Home Titration in Patients with Advanced Parkinson’s Disease

    PubMed Central

    Willows, Thomas; Dizdar, Nil; Nyholm, Dag; Widner, Håkan; Grenholm, Peter; Schmiauke, Ursula; Urbom, Anna; Groth, Kristina; Larsson, Jörgen; Permert, Johan; Kjellander, Susanna

    2017-01-01

    Background: Levodopa-carbidopa intestinal gel (LCIG; Duodopa®) is used for continuous infusion in advanced Parkinson’s disease. To achieve optimal effect, the LCIG dose is individually titrated, traditionally conducted during hospitalization in Sweden. However, dose adjustment depends on surrounding conditions, physical activity, and emotional stress, which is why titration at home could be beneficial. Telemedicine (TM) using a video communication system offers alternative titration procedures, allowing LCIG initiation at home. Objective: Study objectives were to show the feasibility of TM for LCIG home titration, evaluate resource use, and assess patient, neurologist, and nurse satisfaction. Methods: Four clinics enrolled 15 patients to observe efficiency and feasibility of TM-based monitoring. Results: Patient median (range) age was 67 (52–73) years and time since diagnosis was 10 (7–23) years. Median time between LCIG initiation and end of TM-assisted titration was 2.8 (2.0–13.8) days. Median time required for home titration by neurologists, nurses, and patients was (hours:minutes) 1 : 14 (0 : 29–1 : 52), 5 : 49 (2 : 46–10 : 3), and 8 : 53 (4 : 11–14 : 11), respectively. Neurologists and nurses considered this to be less time than required for hospital titration. TM allowed patients 92% free time from start to end of titration. Technical problems associated with TM contacts were rare, mostly related to digital link, and quickly resolved. Patients, neurologists, and nurses were satisfied using TM. No serious adverse events were reported; there was one device complaint (tube occlusion). Conclusions: In this study, TM-assisted LCIG titration at home was resource-efficient, technically feasible, well-accepted and was deemed satisfactory by patients, neurologists, and nurses. PMID:28984615

  16. Non-Aqueous Titration Method for Determining Suppressor Concentration in the MCU Next Generation Solvent (NGS)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Taylor-Pashow, Kathryn M. L.; Jones, Daniel H.

    A non-aqueous titration method has been used for quantifying the suppressor concentration in the MCU solvent hold tank (SHT) monthly samples since the Next Generation Solvent (NGS) was implemented in 2013. The titration method measures the concentration of the NGS suppressor (TiDG) as well as the residual tri-n-octylamine (TOA) that is a carryover from the previous solvent. As the TOA concentration has decreased over time, it has become difficult to resolve the TiDG equivalence point as the TOA equivalence point has moved closer. In recent samples, the TiDG equivalence point could not be resolved, and therefore, the TiDG concentration wasmore » determined by subtracting the TOA concentration as measured by semi-volatile organic analysis (SVOA) from the total base concentration as measured by titration. In order to improve the titration method so that the TiDG concentration can be measured directly, without the need for the SVOA data, a new method has been developed that involves spiking of the sample with additional TOA to further separate the two equivalence points in the titration. This method has been demonstrated on four recent SHT samples and comparison to results obtained using the SVOA TOA subtraction method shows good agreement. Therefore, it is recommended that the titration procedure be revised to include the TOA spike addition, and this to become the primary method for quantifying the TiDG.« less

  17. Chem Ed Compacts

    ERIC Educational Resources Information Center

    Wolf, Walter A., Ed.

    1978-01-01

    Presents four simple laboratory procedures for: preparation of organometallic compounds, a realistic qualitative organic analysis project, a computer program to plot potentiometric titration curves, and preparation of stereoscopic transparencies. (SL)

  18. New approach in the treatment of data from an acid-base potentiometric titrationI. Monocomponent systems of monofunctional acids and bases.

    PubMed

    Maslarska, Vania; Tencheva, Jasmina; Budevsky, Omortag

    2003-01-01

    Based on precise analysis of the acid-base equilibrium, a new approach in the treatment of experimental data from a potentiometric titration is proposed. A new general formula giving explicitly the relation V=f([H(+)]) is derived, valid for every acid-base titration, which includes mono- and polyfunctional protolytes and their mixtures. The present study is the first practical application of this formula for the simplest case, the analysis of one monofunctional protolyte. The collected mV data during the titration are converted into pH-values by means of an auto pH-calibration procedure, thus avoiding preliminary preparation of the measuring system. The mentioned pH-calibration method is applicable also in water-organic mixtures and allows the quantitative determination of sparingly soluble substances (particularly pharmaceuticals). The treatment of the data is performed by means of ready-to-use software products, which makes the proposed approach accessible for a wide range of applications.

  19. On the acid-base properties of humic acid in soil.

    PubMed

    Cooke, James D; Hamilton-Taylor, John; Tipping, Edward

    2007-01-15

    Humic acid was isolated from three contrasting organic-rich soils and acid-base titrations performed over a range of ionic strengths. Results obtained were unlike most humic acid data sets; they showed a greater ionic strength dependency at low pH than at high pH. Forward- and back-titrations with the base and acid revealed hysteresis, particularly at low pH. Previous authors attributed this type of hysteresis to humic acid aggregates-created during the isolation procedure-being redissolved during titration as the pH increased and regarded the results as artificial. However, forward- and back-titrations with organic-rich soils also demonstrated a similar hysteretic behavior. These observations indicate (i) that titrations of humic acid in aggregated form (as opposed to the more usual dissolved form) are more representative of the acid-base properties of humic acid in soil and (ii) that the ionic strength dependency of proton binding in humic acid is related to its degree of aggregation. Thus, the current use of models based on data from dissolved humic substances to predictthe acid-base properties of humic acid in soil under environmental conditions may be flawed and could substantially overestimate their acid buffering capacity.

  20. Developing a multipoint titration method with a variable dose implementation for anaerobic digestion monitoring.

    PubMed

    Salonen, K; Leisola, M; Eerikäinen, T

    2009-01-01

    Determination of metabolites from an anaerobic digester with an acid base titration is considered as superior method for many reasons. This paper describes a practical at line compatible multipoint titration method. The titration procedure was improved by speed and data quality. A simple and novel control algorithm for estimating a variable titrant dose was derived for this purpose. This non-linear PI-controller like algorithm does not require any preliminary information from sample. Performance of this controller is superior compared to traditional linear PI-controllers. In addition, simplification for presenting polyprotic acids as a sum of multiple monoprotic acids is introduced along with a mathematical error examination. A method for inclusion of the ionic strength effect with stepwise iteration is shown. The titration model is presented with matrix notations enabling simple computation of all concentration estimates. All methods and algorithms are illustrated in the experimental part. A linear correlation better than 0.999 was obtained for both acetate and phosphate used as model compounds with slopes of 0.98 and 1.00 and average standard deviations of 0.6% and 0.8%, respectively. Furthermore, insensitivity of the presented method for overlapping buffer capacity curves was shown.

  1. Real Time Intraoperative Monitoring of Blood Loss with a Novel Tablet Application.

    PubMed

    Sharareh, Behnam; Woolwine, Spencer; Satish, Siddarth; Abraham, Peter; Schwarzkopf, Ran

    2015-01-01

    Real-time monitoring of blood loss is critical in fluid management. Visual estimation remains the standard of care in estimating blood loss, yet is demonstrably inaccurate. Photometric analysis, which is the referenced "gold-standard" for measuring blood loss, is both time-consuming and costly. The purpose of this study was to evaluate the efficacy of a novel tablet-monitoring device for measurement of Hb loss during orthopaedic procedures. This is a prospective study of 50 patients in a consecutive series of joint arthroplasty cases. The novel System with Feature Extraction Technology was used to measure the amount of Hb contained within surgical sponges intra-operatively. The system's measures were then compared with those obtained via gravimetric method and photometric analysis. Accuracy was evaluated using linear regression and Bland-Altman analysis. Our results showed a significant positive correlation between Triton tablet system and photometric analysis with respect to intra-operative hemoglobin and blood loss at 0.92 and 0.91, respectively. This novel system can accurately determine Hb loss contained within surgical sponges. We believe that this user-friendly software can be used for measurement of total intraoperative blood loss and thus aid in a more accurate fluid management protocols during orthopaedic surgical procedures.

  2. BASIC Programming In Water And Wastewater Analysis

    NASA Technical Reports Server (NTRS)

    Dreschel, Thomas

    1988-01-01

    Collection of computer programs assembled for use in water-analysis laboratories. First program calculates quality-control parameters used in routine water analysis. Second calculates line of best fit for standard concentrations and absorbances entered. Third calculates specific conductance from conductivity measurement and temperature at which measurement taken. Fourth calculates any one of four types of residue measured in water. Fifth, sixth, and seventh calculate results of titrations commonly performed on water samples. Eighth converts measurements, to actual dissolved-oxygen concentration using oxygen-saturation values for fresh and salt water. Ninth and tenth perform calculations of two other common titrimetric analyses. Eleventh calculates oil and grease residue from water sample. Last two use spectro-photometric measurements of absorbance at different wavelengths and residue measurements. Programs included in collection written for Hewlett-Packard 2647F in H-P BASIC.

  3. Preparation and spectroscopic studies on charge-transfer complexes of 2,2'-bipyridine with picric and chloranilic acids

    NASA Astrophysics Data System (ADS)

    Teleb, Said M.; Gaballa, Akmal S.

    2005-11-01

    Charge-transfer (CT) complexes formed on the reaction of 2,2'-bipyridine with some acceptors such as picric acid (HPA) and chloranilic acid (H 2CA) have been studied in CHCl 3 and MeOH at room temperature. Based on elemental analysis and IR spectra of the solid CT complexes along with the photometric titration curves for the reactions, the data obtained indicate the formation of 1:1 charge-transfer complexes [(bpyH)(PA)] and [(bpyH 2)(CA)], respectively. The infrared and 1H NMR spectroscopic data indicate a charge-transfer interaction associated with a proton migration from the acceptor to the donor followed by intramolecular hydrogen bonding. The formation constants ( KC) for the complexes were shown to be dependent on the structure of the electron acceptors used.

  4. Preparation and spectroscopic studies on charge-transfer complexes of 2,2'-bipyridine with picric and chloranilic acids.

    PubMed

    Teleb, Said M; Gaballa, Akmal S

    2005-11-01

    Charge-transfer (CT) complexes formed on the reaction of 2,2'-bipyridine with some acceptors such as picric acid (HPA) and chloranilic acid (H(2)CA) have been studied in CHCl(3) and MeOH at room temperature. Based on elemental analysis and IR spectra of the solid CT complexes along with the photometric titration curves for the reactions, the data obtained indicate the formation of 1:1 charge-transfer complexes [(bpyH)(PA)] and [(bpyH(2))(CA)], respectively. The infrared and (1)H NMR spectroscopic data indicate a charge-transfer interaction associated with a proton migration from the acceptor to the donor followed by intramolecular hydrogen bonding. The formation constants (K(C)) for the complexes were shown to be dependent on the structure of the electron acceptors used.

  5. Thermodynamics study of the dimerization equilibria of rhodamine B and 6G in different ionic strengths by photometric titration and chemometrics method

    NASA Astrophysics Data System (ADS)

    Ghasemi, Jahanbakhsh; Niazi, Ali; Kubista, Mikael

    2005-11-01

    The dimerization constants of rhodamine B and 6G have been determined by studying the dependence of their absorption spectra on the temperature in the range 20-80 °C at different total concentrations of rhodamine B (5.89 × 10 -6 to 2.36 × 10 -4 M) and rhodamine 6G (2.34 × 10 -5 to 5.89 × 10 -4 M) and in different concentrations of LiCl, NaCl and KCl salts as supporting electrolytes. The monomer-dimer equilibrium of rhodamine B and 6G have been determined by chemometrics refinement of the absorption spectra obtained by thermometric titrations performed at different ionic strengths. The quantitative analysis of the data of undefined mixtures, was carried out by simultaneous resolution of the overlapping spectral bands in the whole set of absorption spectra. The dimerization constants are varied by changing the ionic strength and the degree of dimerization are decreased by increasing of the ionic strength of the medium. The enthalpy and entropy of the dimerization reactions were determined from the dependence of the equilibrium constants on the temperature (van't Hoff equation). From the thermodynamic results the TΔ S°-Δ H° plot was sketched. It shows a fairly good positive correlation which indicates the enthalpy-entropy compensation in the dimerization reactions (compensation effect).

  6. Thermodynamics study of the dimerization equilibria of rhodamine B and 6G in different ionic strengths by photometric titration and chemometrics method.

    PubMed

    Ghasemi, Jahanbakhsh; Niazi, Ali; Kubista, Mikael

    2005-11-01

    The dimerization constants of rhodamine B and 6G have been determined by studying the dependence of their absorption spectra on the temperature in the range 20-80 degrees C at different total concentrations of rhodamine B (5.89 x 10(-6) to 2.36 x 10(-4)M) and rhodamine 6G (2.34 x 10(-5) to 5.89 x 10(-4)M) and in different concentrations of LiCl, NaCl and KCl salts as supporting electrolytes. The monomer-dimer equilibrium of rhodamine B and 6G have been determined by chemometrics refinement of the absorption spectra obtained by thermometric titrations performed at different ionic strengths. The quantitative analysis of the data of undefined mixtures, was carried out by simultaneous resolution of the overlapping spectral bands in the whole set of absorption spectra. The dimerization constants are varied by changing the ionic strength and the degree of dimerization are decreased by increasing of the ionic strength of the medium. The enthalpy and entropy of the dimerization reactions were determined from the dependence of the equilibrium constants on the temperature (van't Hoff equation). From the thermodynamic results the TDeltaS degrees -DeltaH degrees plot was sketched. It shows a fairly good positive correlation which indicates the enthalpy-entropy compensation in the dimerization reactions (compensation effect).

  7. The CCD Photometric Calibration Cookbook

    NASA Astrophysics Data System (ADS)

    Palmer, J.; Davenhall, A. C.

    This cookbook presents simple recipes for the photometric calibration of CCD frames. Using these recipes you can calibrate the brightness of objects measured in CCD frames into magnitudes in standard photometric systems, such as the Johnson-Morgan UBV, system. The recipes use standard software available at all Starlink sites. The topics covered include: selecting standard stars, measuring instrumental magnitudes and calibrating instrumental magnitudes into a standard system. The recipes are appropriate for use with data acquired with optical CCDs and filters, operated in standard ways, and describe the usual calibration technique of observing standard stars. The software is robust and reliable, but the techniques are usually not suitable where very high accuracy is required. In addition to the recipes and scripts, sufficient background material is presented to explain the procedures and techniques used. The treatment is deliberately practical rather than theoretical, in keeping with the aim of providing advice on the actual calibration of observations. This cookbook is aimed firmly at people who are new to astronomical photometry. Typical readers might have a set of photometric observations to reduce (perhaps observed by a colleague) or be planning a programme of photometric observations, perhaps for the first time. No prior knowledge of astronomical photometry is assumed. The cookbook is not aimed at experts in astronomical photometry. Many finer points are omitted for clarity and brevity. Also, in order to make the most accurate possible calibration of high-precision photometry, it is usually necessary to use bespoke software tailored to the observing programme and photometric system you are using.

  8. Wet Labs, Computers, and Spreadsheets.

    ERIC Educational Resources Information Center

    Durham, Bill

    1990-01-01

    Described are some commonly encountered chemistry experiments that have been modified for computerized data acquisition. Included are exercises in radioactivity, titration, calorimetry, kinetics, and electrochemistry. Software considerations and laboratory procedures are discussed. (CW)

  9. Iron Analysis by Redox Titration. A General Chemistry Experiment.

    ERIC Educational Resources Information Center

    Kaufman, Samuel; DeVoe, Howard

    1988-01-01

    Describes a simplified redox method for total iron analysis suitable for execution in a three-hour laboratory period by general chemistry students. Discusses materials, procedures, analyses, and student performance. (CW)

  10. A potentiometric titration method for the crystallization of drug-like organic molecules.

    PubMed

    Du-Cuny, Lei; Huwyler, Jörg; Fischer, Holger; Kansy, Manfred

    2007-09-05

    It is generally accepted, that crystalline solids representing a low energy polymorph should be selected for development of oral dosage forms. As a consequence, efficient and robust procedures are needed at an early stage during drug discovery to prepare crystals from drug-like organic molecules. In contrast to the use of supersaturated solutions, we present a potentiometric crystallization procedure where saturated solutions are prepared in a controlled manner by pH-titration. Crystallization is carried out under defined conditions using the sample concentration and experimental pK(a) values as input parameters. Crystals of high quality were obtained for 11 drugs selected to demonstrate the efficiency and applicability of the new method. Technical improvements are suggested to overcome practical limitations and to enhance the possibility of obtaining crystals from molecules in their uncharged form.

  11. A semi-grand canonical Monte Carlo simulation model for ion binding to ionizable surfaces: proton binding of carboxylated latex particles as a case study.

    PubMed

    Madurga, Sergio; Rey-Castro, Carlos; Pastor, Isabel; Vilaseca, Eudald; David, Calin; Garcés, Josep Lluís; Puy, Jaume; Mas, Francesc

    2011-11-14

    In this paper, we present a computer simulation study of the ion binding process at an ionizable surface using a semi-grand canonical Monte Carlo method that models the surface as a discrete distribution of charged and neutral functional groups in equilibrium with explicit ions modelled in the context of the primitive model. The parameters of the simulation model were tuned and checked by comparison with experimental titrations of carboxylated latex particles in the presence of different ionic strengths of monovalent ions. The titration of these particles was analysed by calculating the degree of dissociation of the latex functional groups vs. pH curves at different background salt concentrations. As the charge of the titrated surface changes during the simulation, a procedure to keep the electroneutrality of the system is required. Here, two approaches are used with the choice depending on the ion selected to maintain electroneutrality: counterion or coion procedures. We compare and discuss the difference between the procedures. The simulations also provided a microscopic description of the electrostatic double layer (EDL) structure as a function of pH and ionic strength. The results allow us to quantify the effect of the size of the background salt ions and of the surface functional groups on the degree of dissociation. The non-homogeneous structure of the EDL was revealed by plotting the counterion density profiles around charged and neutral surface functional groups. © 2011 American Institute of Physics

  12. Automated potentiometric titrations in KCl/water-saturated octanol: method for quantifying factors influencing ion-pair partitioning.

    PubMed

    Scherrer, Robert A; Donovan, Stephen F

    2009-04-01

    The knowledge base of factors influencing ion pair partitioning is very sparse, primarily because of the difficulty in determining accurate log P(I) values of desirable low molecular weight (MW) reference compounds. We have developed a potentiometric titration procedure in KCl/water-saturated octanol that provides a link to log P(I) through the thermodynamic cycle of ionization and partitioning. These titrations have the advantage of being independent of the magnitude of log P, while maintaining a reproducibility of a few hundredths of a log P in the calculated difference between log P neutral and log P ion pair (diff (log P(N - I))). Simple model compounds can be used. The titration procedure is described in detail, along with a program for calculating pK(a)'' values incorporating the ionization of water in octanol. Hydrogen bonding and steric factors have a greater influence on ion pairs than they do on neutral species, yet these factors are missing from current programs used to calculate log P(I) and log D. In contrast to the common assumption that diff (log P(N - I)) is the same for all amines, they can actually vary more than 3 log units, as in our examples. A major factor affecting log P(I) is the ability of water and the counterion to approach the charge center. Bulky substituents near the charge center have a negative influence on log P(I). On the other hand, hydrogen bonding groups near the charge center have the opposite effect by lowering the free energy of the ion pair. The use of this titration method to determine substituent ion pair stabilization values (IPS) should bring about more accurate log D calculations and encourage species-specific QSAR involving log D(N) and log D(I). This work also brings attention to the fascinating world of nature's highly stabilized ion pairs.

  13. Automated Potentiometric Titrations in KCl/Water-Saturated Octanol: Method for Quantifying Factors Influencing Ion-Pair Partitioning

    PubMed Central

    2009-01-01

    The knowledge base of factors influencing ion pair partitioning is very sparse, primarily because of the difficulty in determining accurate log PI values of desirable low molecular weight (MW) reference compounds. We have developed a potentiometric titration procedure in KCl/water-saturated octanol that provides a link to log PI through the thermodynamic cycle of ionization and partitioning. These titrations have the advantage of being independent of the magnitude of log P, while maintaining a reproducibility of a few hundredths of a log P in the calculated difference between log P neutral and log P ion pair (diff (log PN − I)). Simple model compounds can be used. The titration procedure is described in detail, along with a program for calculating pKa′′ values incorporating the ionization of water in octanol. Hydrogen bonding and steric factors have a greater influence on ion pairs than they do on neutral species, yet these factors are missing from current programs used to calculate log PI and log D. In contrast to the common assumption that diff (log PN − I) is the same for all amines, they can actually vary more than 3 log units, as in our examples. A major factor affecting log PI is the ability of water and the counterion to approach the charge center. Bulky substituents near the charge center have a negative influence on log PI. On the other hand, hydrogen bonding groups near the charge center have the opposite effect by lowering the free energy of the ion pair. The use of this titration method to determine substituent ion pair stabilization values (IPS) should bring about more accurate log D calculations and encourage species-specific QSAR involving log DN and log DI. This work also brings attention to the fascinating world of nature’s highly stabilized ion pairs. PMID:19265385

  14. Isolating behavioral mechanisms of intertemporal choice: nicotine effects on delay discounting and amount sensitivity.

    PubMed

    Locey, Matthew L; Dallery, Jesse

    2009-03-01

    Many drugs of abuse produce changes in impulsive choice, that is, choice for a smaller-sooner reinforcer over a larger-later reinforcer. Because the alternatives differ in both delay and amount, it is not clear whether these drug effects are due to the differences in reinforcer delay or amount. To isolate the effects of delay, we used a titrating delay procedure. In phase 1, 9 rats made discrete choices between variable delays (1 or 19 s, equal probability of each) and a delay to a single food pellet. The computer titrated the delay to a single food pellet until the rats were indifferent between the two options. This indifference delay was used as the starting value for the titrating delay for all future sessions. We next evaluated the acute effects of nicotine (subcutaneous 1.0, 0.3, 0.1, and 0.03 mg/kg) on choice. If nicotine increases delay discounting, it should have increased preference for the variable delay. Instead, nicotine had very little effect on choice. In a second phase, the titrated delay alternative produced three food pellets instead of one, which was again produced by the variable delay (1 s or 19 s) alternative. Under this procedure, nicotine increased preference for the one pellet alternative. Nicotine-induced changes in impulsive choice are therefore likely due to differences in reinforcer amount rather than differences in reinforcer delay. In addition, it may be necessary to include an amount sensitivity parameter in any mathematical model of choice when the alternatives differ in reinforcer amount.

  15. Real Time Intraoperative Monitoring of Blood Loss with a Novel Tablet Application

    PubMed Central

    Sharareh, Behnam; Woolwine, Spencer; Satish, Siddarth; Abraham, Peter; Schwarzkopf, Ran

    2015-01-01

    Introduction : Real-time monitoring of blood loss is critical in fluid management. Visual estimation remains the standard of care in estimating blood loss, yet is demonstrably inaccurate. Photometric analysis, which is the referenced “gold-standard” for measuring blood loss, is both time-consuming and costly. The purpose of this study was to evaluate the efficacy of a novel tablet-monitoring device for measurement of Hb loss during orthopaedic procedures. Methods : This is a prospective study of 50 patients in a consecutive series of joint arthroplasty cases. The novel System with Feature Extraction Technology was used to measure the amount of Hb contained within surgical sponges intra-operatively. The system’s measures were then compared with those obtained via gravimetric method and photometric analysis. Accuracy was evaluated using linear regression and Bland-Altman analysis. Results : Our results showed a significant positive correlation between Triton tablet system and photometric analysis with respect to intra-operative hemoglobin and blood loss at 0.92 and 0.91, respectively. Discussion : This novel system can accurately determine Hb loss contained within surgical sponges. We believe that this user-friendly software can be used for measurement of total intraoperative blood loss and thus aid in a more accurate fluid management protocols during orthopaedic surgical procedures. PMID:26401167

  16. A photometric study of the Orion OB 1 association. 2: Photometric analysis

    NASA Technical Reports Server (NTRS)

    Warren, W. H., Jr.; Hesser, J. E.

    1976-01-01

    The procedures adopted for analysis of photometric data in terms of color excesses, intrinsic color indexes, absolute visual magnitudes, and rotational-velocity effects are discussed in detail for Orion association B-, intermediate (I)-, and AF-type stars. The effects of the nebular environment and a comparison of various calibrations of Balmer-line and four-color indexes are considered for the determination of individual absolute magnitudes for B-type stars. When absolute magnitudes of stars in the region of the Orion Nebula are determined from the beta index, emission mechanisms appear to spuriously brighten them. A detailed comparison of absolute magnitudes derived from Balmer-line indexes and MK spectral-type calibrations is presented. The data are also examined with regard to the effects of polarization and infrared excesses. The results suggest a complex combination of intracluster and circumstellar origins for these processes.

  17. Introducing PLIA: Planetary Laboratory for Image Analysis

    NASA Astrophysics Data System (ADS)

    Peralta, J.; Hueso, R.; Barrado, N.; Sánchez-Lavega, A.

    2005-08-01

    We present a graphical software tool developed under IDL software to navigate, process and analyze planetary images. The software has a complete Graphical User Interface and is cross-platform. It can also run under the IDL Virtual Machine without the need to own an IDL license. The set of tools included allow image navigation (orientation, centring and automatic limb determination), dynamical and photometric atmospheric measurements (winds and cloud albedos), cylindrical and polar projections, as well as image treatment under several procedures. Being written in IDL, it is modular and easy to modify and grow for adding new capabilities. We show several examples of the software capabilities with Galileo-Venus observations: Image navigation, photometrical corrections, wind profiles obtained by cloud tracking, cylindrical projections and cloud photometric measurements. Acknowledgements: This work has been funded by Spanish MCYT PNAYA2003-03216, fondos FEDER and Grupos UPV 15946/2004. R. Hueso acknowledges a post-doc fellowship from Gobierno Vasco.

  18. EPA Method 614: The Determination of Organophosphorus Pesticides in Municipal and Industrial Wastewater

    EPA Pesticide Factsheets

    Method 614 describes procedures for preparation and analysis of samples for determination of organophosphate pesticides in industrial and municipal discharges using a GC with a phosphorus-specific flame photometric detector (FPD).

  19. Spectroscopic and structural characterization of the charge-transfer interaction of N,N'-bis-alkyl derivatives of 1,4,6,8-naphthalenediimide with chloranilic and picric acids.

    PubMed

    Refat, Moamen S; Ahmed, Hamdy A; Grabchev, Ivo; El-Zayat, Lamia A

    2008-09-01

    Charge-transfer (CT) complexes formed from the reactions of two N,N'-bis-alkyl derivatives of 1,4,6,8-naphthalenediimide such as N,N'-bis[2-hydroxyethyl)]-1,4,6,8-naphthalenediimide (BHENDI) and N,N'-bis-[2-N,N-dimethylaminoethyl)]-1,4,6,8-naphthalenediimide (BDMAENDI) with chloranilic acid (CLA) and piciric acid (PA) as pi-acceptors, have been studied spectrophotometrically in methanol and chloroform, respectively at 25 degrees C. The photometric titration curves for the reactions indicated that the data obtained refer to 1:1 charge-transfer complexes of [(BHENDI)(CLA)], [(BDMAENDI)(CLA)], [(BHENDI)(PA)] and [(BDMAENDI)(PA)] were formed. Benesi-Hildebrand and its modification methods were applied to the determination of association constant (K), molar extinction coefficient (epsilon). The solid CT complexes have been synthesized and characterization by different spectral methods.

  20. Spectroscopic and structural characterization of the charge-transfer interaction of N,N'-bis-alkyl derivatives of 1,4,6,8-naphthalenediimide with chloranilic and picric acids

    NASA Astrophysics Data System (ADS)

    Refat, Moamen S.; Ahmed, Hamdy A.; Grabchev, Ivo; El-Zayat, Lamia A.

    2008-09-01

    Charge-transfer (CT) complexes formed from the reactions of two N,N'-bis-alkyl derivatives of 1,4,6,8-naphthalenediimide such as N, N'-bis[2-hydroxyethyl)]-1,4,6,8-naphthalenediimide (BHENDI) and N, N'-bis-[2- N, N-dimethylaminoethyl)]-1,4,6,8-naphthalenediimide (BDMAENDI) with chloranilic acid (CLA) and piciric acid (PA) as π-acceptors, have been studied spectrophotometrically in methanol and chloroform, respectively at 25 °C. The photometric titration curves for the reactions indicated that the data obtained refer to 1:1 charge-transfer complexes of [(BHENDI)(CLA)], [(BDMAENDI)(CLA)], [(BHENDI)(PA)] and [(BDMAENDI)(PA)] were formed. Benesi-Hildebrand and its modification methods were applied to the determination of association constant ( K), molar extinction coefficient ( ɛ). The solid CT complexes have been synthesized and characterization by different spectral methods.

  1. Combination of Continuous Dexmedetomidine Infusion with Titrated Ultra-Low-Dose Propofol-Fentanyl for an Awake Craniotomy

    PubMed Central

    Das, Samaresh; Al-Mashani, Ali; Suri, Neelam; Salhotra, Neeraj; Chatterjee, Nilay

    2016-01-01

    An awake craniotomy is a continuously evolving technique used for the resection of brain tumours from the eloquent cortex. We report a 29-year-old male patient who presented to the Khoula Hospital, Muscat, Oman, in 2016 with a two month history of headaches and convulsions due to a space-occupying brain lesion in close proximity with the left motor cortex. An awake craniotomy was conducted using a scalp block, continuous dexmedetomidine infusion and a titrated ultra-low-dose of propofolfentanyl. The patient remained comfortable throughout the procedure and the intraoperative neuropsychological tests, brain mapping and tumour resection were successful. This case report suggests that dexmedetomidine in combination with titrated ultra-low-dose propofolfentanyl are effective options during an awake craniotomy, ensuring optimum sedation, minimal disinhibition and a rapid recovery. To the best of the authors’ knowledge, this is the first awake craniotomy conducted successfully in Oman. PMID:27606116

  2. Rapid analytical determination of glutaraldehyde concentrations

    NASA Technical Reports Server (NTRS)

    Frigerio, N. A.; Shaw, M. H.

    1971-01-01

    Technique utilizes the iodimetric procedure which adds unknown excess of bisulfite to glutaraldehyde /GA/ then titrates unreacted bisulfite with standard iodine isotope to determine GA concentrations. Technique may interest microscopists, food researchers, biochemical or medical laboratories, and drug manufacturers.

  3. Dark Energy Survey Year 1 results: cross-correlation redshifts - methods and systematics characterization

    NASA Astrophysics Data System (ADS)

    Gatti, M.; Vielzeuf, P.; Davis, C.; Cawthon, R.; Rau, M. M.; DeRose, J.; De Vicente, J.; Alarcon, A.; Rozo, E.; Gaztanaga, E.; Hoyle, B.; Miquel, R.; Bernstein, G. M.; Bonnett, C.; Carnero Rosell, A.; Castander, F. J.; Chang, C.; da Costa, L. N.; Gruen, D.; Gschwend, J.; Hartley, W. G.; Lin, H.; MacCrann, N.; Maia, M. A. G.; Ogando, R. L. C.; Roodman, A.; Sevilla-Noarbe, I.; Troxel, M. A.; Wechsler, R. H.; Asorey, J.; Davis, T. M.; Glazebrook, K.; Hinton, S. R.; Lewis, G.; Lidman, C.; Macaulay, E.; Möller, A.; O'Neill, C. R.; Sommer, N. E.; Uddin, S. A.; Yuan, F.; Zhang, B.; Abbott, T. M. C.; Allam, S.; Annis, J.; Bechtol, K.; Brooks, D.; Burke, D. L.; Carollo, D.; Carrasco Kind, M.; Carretero, J.; Cunha, C. E.; D'Andrea, C. B.; DePoy, D. L.; Desai, S.; Eifler, T. F.; Evrard, A. E.; Flaugher, B.; Fosalba, P.; Frieman, J.; García-Bellido, J.; Gerdes, D. W.; Goldstein, D. A.; Gruendl, R. A.; Gutierrez, G.; Honscheid, K.; Hoormann, J. K.; Jain, B.; James, D. J.; Jarvis, M.; Jeltema, T.; Johnson, M. W. G.; Johnson, M. D.; Krause, E.; Kuehn, K.; Kuhlmann, S.; Kuropatkin, N.; Li, T. S.; Lima, M.; Marshall, J. L.; Melchior, P.; Menanteau, F.; Nichol, R. C.; Nord, B.; Plazas, A. A.; Reil, K.; Rykoff, E. S.; Sako, M.; Sanchez, E.; Scarpine, V.; Schubnell, M.; Sheldon, E.; Smith, M.; Smith, R. C.; Soares-Santos, M.; Sobreira, F.; Suchyta, E.; Swanson, M. E. C.; Tarle, G.; Thomas, D.; Tucker, B. E.; Tucker, D. L.; Vikram, V.; Walker, A. R.; Weller, J.; Wester, W.; Wolf, R. C.

    2018-06-01

    We use numerical simulations to characterize the performance of a clustering-based method to calibrate photometric redshift biases. In particular, we cross-correlate the weak lensing source galaxies from the Dark Energy Survey Year 1 sample with redMaGiC galaxies (luminous red galaxies with secure photometric redshifts) to estimate the redshift distribution of the former sample. The recovered redshift distributions are used to calibrate the photometric redshift bias of standard photo-z methods applied to the same source galaxy sample. We apply the method to two photo-z codes run in our simulated data: Bayesian Photometric Redshift and Directional Neighbourhood Fitting. We characterize the systematic uncertainties of our calibration procedure, and find that these systematic uncertainties dominate our error budget. The dominant systematics are due to our assumption of unevolving bias and clustering across each redshift bin, and to differences between the shapes of the redshift distributions derived by clustering versus photo-zs. The systematic uncertainty in the mean redshift bias of the source galaxy sample is Δz ≲ 0.02, though the precise value depends on the redshift bin under consideration. We discuss possible ways to mitigate the impact of our dominant systematics in future analyses.

  4. Titration of individual strains in trivalent live-attenuated influenza vaccine without neutralization.

    PubMed

    Sirinonthanawech, Naraporn; Surichan, Somchaiya; Namsai, Aphinya; Puthavathana, Pilaipan; Auewarakul, Prasert; Kongchanagul, Alita

    2016-11-01

    Formulation and quality control of trivalent live-attenuated influenza vaccine requires titration of infectivity of individual strains in the trivalent mix. This is usually performed by selective neutralization of two of the three strains and titration of the un-neutralized strain in cell culture or embryonated eggs. This procedure requires standard sera with high neutralizing titer against each of the three strains. Obtaining standard sera, which can specifically neutralize only the corresponding strain of influenza viruses and is able to completely neutralize high concentration of virus in the vaccine samples, can be a problem for many vaccine manufacturers as vaccine stocks usually have very high viral titers and complete neutralization may not be obtained. Here an alternative approach for titration of individual strain in trivalent vaccine without the selective neutralization is presented. This was done by detecting individual strains with specific antibodies in an end-point titration of a trivalent vaccine in cell culture. Similar titers were observed in monovalent and trivalent vaccines for influenza A H3N2 and influenza B strains, whereas the influenza A H1N1 strain did not grow well in cell culture. Viral interference among the vaccine strains was not observed. Therefore, providing that vaccine strains grow well in cell culture, this assay can reliably determine the potency of individual strains in trivalent live-attenuated influenza vaccines. Copyright © 2016 Elsevier B.V. All rights reserved.

  5. Surface acid-base behaviors of Chinese loess.

    PubMed

    Chu, Zhaosheng; Liu, Wenxin; Tang, Hongxiao; Qian, Tianwei; Li, Shushen; Li, Zhentang; Wu, Guibin

    2002-08-15

    Acid-base titration was applied to investigate the surface acid-base properties of a Chinese loess sample at different ionic strengths. The acidimetric supernatant was regarded as the system blank of titration to correct the influence of particle dissolution on the estimation of proton consumption. The titration behavior of the system blank could be described by the hydrolysis of Al3+ and Si(OH)4 in aqueous solution as well as the production of hydroxyaluminosilicates. The formation of Al-Si species on homogeneous surface sites by hydrous aluminum and silicic acid, released from solid substrate during the acidic titration, was considered in the model description of the back-titration procedure. A surface reaction model was suggested as follows: >SOH<-->SO(-)+H+, pK(a)(int)=3.48-3.98;>SOH+Al(3+)+H4SiO4<-->SOAl(OSi(OH)3(+)+2H+, pK(SC)=3.48-4.04. Two simple surface complexation models accounted for the interfacial structure, i.e., the constant capacitance model (CCM) and the diffuse layer model (DLM), and gave a satisfactory description of the experimental data. Considering the effect of ionic strength on the electrostatic profile at the solid-aqueous interface, the DLM was appropriate at the low concentrations (0.01 and 0.005 mol/L) of background electrolyte (NaNO3 in this study), while the CCM was preferable in the case of high ionic strength (0.1 mol/L).

  6. Ti(IV) and the Siderophore Desferrioxamine B: A Tight Complex Has Biological and Environmental Implications.

    PubMed

    Jones, Kayleigh E; Batchler, Kathleen L; Zalouk, Célia; Valentine, Ann M

    2017-02-06

    The siderophore desferrioxamine B (DFOB) binds Ti(IV) tightly and precludes its hydrolytic precipitation under biologically and environmentally relevant conditions. This interaction of DFOB with Ti(IV) is investigated by using spectro-potentiometric and spectro-photometric titrations, mass spectrometry, isothermal titration calorimetry (ITC), and computational modeling. The data from pH 2-10 suggest two one-proton equilibria among three species, with one species predominating below pH 3.5, a second from pH 3.5 to 8, and a third above pH 8. The latter species is prone to slow hydrolytic precipitation. Electrospray mass spectrometry allowed the detection of [Ti(IV) (HDFOB)] 2+ and [Ti(DFOB)] + ; these species were assigned as the pH < 3.5 and the 3.5 < pH < 8 species, respectively. The stability constant for Ti(IV)-DFOB was determined by using UV/vis-monitored competition with ethylenediaminetetraacetic acid (EDTA). Taking into consideration the available binding constant of Ti(IV) and EDTA, the data reveal values of log β 111 = 41.7, log β 110 = 38.1, and log β 11-1 = 30.1. The former value was supported by ITC, with the transfer of Ti(IV) from EDTA to DFOB determined to be both enthalpically and entropically favorable. Computational methods yielded a model of Ti-DFOB. The physiological and environmental implications of this tight interaction and the potential role of DFOB in solubilizing Ti(IV) are discussed.

  7. The Exchange.

    ERIC Educational Resources Information Center

    Blain, Mary P., Ed.; Pintavalle, Steven J., Ed.

    1985-01-01

    Presents 10 activities in biology, chemistry, physical science, and general science. Activities focus on: alfalfa sprouts; soap test; density; skating on cold ice; Kirlian photography; titration analysis (with program listing); radioactive decay; and others. Each activity includes suggested grade level(s) and procedures. (DH)

  8. An Empirical Formula From Ion Exchange Chromatography and Colorimetry.

    ERIC Educational Resources Information Center

    Johnson, Steven D.

    1996-01-01

    Presents a detailed procedure for finding an empirical formula from ion exchange chromatography and colorimetry. Introduces students to more varied techniques including volumetric manipulation, titration, ion-exchange, preparation of a calibration curve, and the use of colorimetry. (JRH)

  9. TESS Data Processing and Quick-look Pipeline

    NASA Astrophysics Data System (ADS)

    Fausnaugh, Michael; Huang, Xu; Glidden, Ana; Guerrero, Natalia; TESS Science Office

    2018-01-01

    We describe the data analysis procedures and pipelines for the Transiting Exoplanet Survey Satellite (TESS). We briefly review the processing pipeline developed and implemented by the Science Processing Operations Center (SPOC) at NASA Ames, including pixel/full-frame image calibration, photometric analysis, pre-search data conditioning, transiting planet search, and data validation. We also describe data-quality diagnostic analyses and photometric performance assessment tests. Finally, we detail a "quick-look pipeline" (QLP) that has been developed by the MIT branch of the TESS Science Office (TSO) to provide a fast and adaptable routine to search for planet candidates in the 30 minute full-frame images.

  10. The third data release of the Kilo-Degree Survey and associated data products

    NASA Astrophysics Data System (ADS)

    de Jong, Jelte T. A.; Verdois Kleijn, Gijs A.; Erben, Thomas; Hildebrandt, Hendrik; Kuijken, Konrad; Sikkema, Gert; Brescia, Massimo; Bilicki, Maciej; Napolitano, Nicola R.; Amaro, Valeria; Begeman, Kor G.; Boxhoorn, Danny R.; Buddelmeijer, Hugo; Cavuoti, Stefano; Getman, Fedor; Grado, Aniello; Helmich, Ewout; Huang, Zhuoyi; Irisarri, Nancy; La Barbera, Francesco; Longo, Giuseppe; McFarland, John P.; Nakajima, Reiko; Paolillo, Maurizio; Puddu, Emanuella; Radovich, Mario; Rifatto, Agatino; Tortora, Crescenzo; Valentijn, Edwin A.; Vellucci, Civita; Vriend, Willem-Jan; Amon, Alexandra; Blake, Chris; Choi, Ami; Conti, Ian Fenech; Gwyn, Stephen D. J.; Herbonnet, Ricardo; Heymans, Catherine; Hoekstra, Henk; Klaes, Dominik; Merten, Julian; Miller, Lance; Schneider, Peter; Viola, Massimo

    2017-08-01

    Context. The Kilo-Degree Survey (KiDS) is an ongoing optical wide-field imaging survey with the OmegaCAM camera at the VLT Survey Telescope. It aims to image 1500 square degrees in four filters (ugri). The core science driver is mapping the large-scale matter distribution in the Universe, using weak lensing shear and photometric redshift measurements. Further science cases include galaxy evolution, Milky Way structure, detection of high-redshift clusters, and finding rare sources such as strong lenses and quasars. Aims: Here we present the third public data release and several associated data products, adding further area, homogenized photometric calibration, photometric redshifts and weak lensing shear measurements to the first two releases. Methods: A dedicated pipeline embedded in the Astro-WISE information system is used for the production of the main release. Modifications with respect to earlier releases are described in detail. Photometric redshifts have been derived using both Bayesian template fitting, and machine-learning techniques. For the weak lensing measurements, optimized procedures based on the THELI data reduction and lensfit shear measurement packages are used. Results: In this third data release an additional 292 new survey tiles (≈300 deg2) stacked ugri images are made available, accompanied by weight maps, masks, and source lists. The multi-band catalogue, including homogenized photometry and photometric redshifts, covers the combined DR1, DR2 and DR3 footprint of 440 survey tiles (44 deg2). Limiting magnitudes are typically 24.3, 25.1, 24.9, 23.8 (5σ in a 2'' aperture) in ugri, respectively, and the typical r-band PSF size is less than 0.7''. The photometric homogenization scheme ensures accurate colours and an absolute calibration stable to ≈2% for gri and ≈3% in u. Separately released for the combined area of all KiDS releases to date are a weak lensing shear catalogue and photometric redshifts based on two different machine-learning techniques.

  11. Photometric properties of Mars soils analogs

    USGS Publications Warehouse

    Pommerol, A.; Thomas, N.; Jost, B.; Beck, P.; Okubo, C.; McEwen, A.S.

    2013-01-01

    We have measured the bidirectional reflectance of analogs of dry, wet, and frozen Martian soils over a wide range of phase angles in the visible spectral range. All samples were produced from two geologic samples: the standard JSC Mars-1 soil simulant and Hawaiian basaltic sand. In a first step, experiments were conducted with the dry samples to investigate the effects of surface texture. Comparisons with results independently obtained by different teams with similar samples showed a satisfying reproducibility of the photometric measurements as well as a noticeable influence of surface textures resulting from different sample preparation procedures. In a second step, water was introduced to produce wet and frozen samples and their photometry investigated. Optical microscope images of the samples provided information about their microtexture. Liquid water, even in relatively low amount, resulted in the disappearance of the backscattering peak and the appearance of a forward-scattering peak whose intensity increases with the amount of water. Specular reflections only appeared when water was present in an amount large enough to allow water to form a film at the surface of the sample. Icy samples showed a wide variability of photometric properties depending on the physical properties of the water ice. We discuss the implications of these measurements in terms of the expected photometric behavior of the Martian surface, from equatorial to circum-polar regions. In particular, we propose some simple photometric criteria to improve the identification of wet and/or icy soils from multiple observations under different geometries.

  12. Comparative study of titrated oral misoprostol solution and vaginal dinoprostone for labor induction at term pregnancy.

    PubMed

    Wang, Xiu; Yang, Aijun; Ma, Qingyong; Li, Xuelan; Qin, Li; He, Tongqiang

    2016-09-01

    To evaluate effectiveness and safety of titrated oral misoprostol solution (OMS) in comparison with vaginal dinoprostone for cervix ripening and labor induction in term pregnant women. A multicenter randomized controlled trial of women with term singleton pregnancy with indications for labor induction; 481 participants were allocated to receive titrated OMS with different doses by hourly administration according to the procedure or insert vaginal dinoprostone for cervix ripening and labor induction to compare maternal outcomes including indication of labor induction, mode of outcome of delivery, maternal morbidity, and neonatal outcomes between two groups for evaluating the efficacy and safety of titrated oral misoprostol induction. Proportion of delivery within 12 h of titrated oral misoprostol is significantly less than vaginal dinoprostone (p = 0.03), but no difference of total vaginal delivery rate (p = 0.93); the mean time of first treatment to vaginal delivery was longer in OMS group (21.3 ± 14.5 h) compared with the vaginal dinoprostone group (15.7 ± 9.6 h). Although the proportion of cesarean section between the two groups showed no statistically significant difference, OMS group showed significantly lower frequency of uterine hyperstimulation, hypertonus, partus precipitatus and non-reassuring fetal heart rate than dinoprostone group. Neonatal outcomes were similar evaluating from Apgar score and NICU admission. Our study also showed that labor induction of women with cervix Bishop score ≤3 needed increased dosage of misoprostol solution. Titrated OMS is as effective as vaginal dinoprostone in labor induction for term pregnant women, with safer effect for its lower rate of adverse effect for women.

  13. Aquaporin-4 antibody titration in NMO patients treated with rituximab: A retrospective study.

    PubMed

    Valentino, Paola; Marnetto, Fabiana; Granieri, Letizia; Capobianco, Marco; Bertolotto, Antonio

    2017-03-01

    We undertook an observational retrospective study to investigate the usefulness of aquaporin-4 (AQP4) antibodies (Ab) titration in the management of patients with neuromyelitis optica (NMO) treated with rituximab (RTX) by studying (1) the correlation between AQP4-Ab titer and disease activity, (2) the influence of RTX on antibody levels, and (3) the association between AQP4-Ab levels and responsiveness to RTX. A cell-based assay was used for AQP4-Ab titration in 322 serum samples from 7 patients with NMO treated with RTX (median follow-up 65 months), according to a treatment-to-target approach. Serum samples were collected every month following standardized procedures. (1) In group analysis, AQP4-Ab titers correlated with the disease activity, showing higher titers during and preceding relapses than during remission. However, in individual analysis, an increase in AQP4-Ab titers and CD19+ B cells did not always precede a relapse. (2) A reduction of AQP4-Ab titers in the short-term and long-term period was observed during RTX treatment. (3) Reduction of AQP4-Ab titers was observed in responder patients both 3 months after RTX infusion and in the long-term follow-up. In one nonresponder patient, AQP4-Ab levels never decreased during the treatment period. Titration of AQP4-Abs could be useful in the clinical management of patients with NMO treated with RTX: titration before each reinfusion and 3 months after each reinfusion may provide information about responsiveness to RTX. Although a relationship among AQP4-Ab levels, disease activity, and response to RTX was observed, the usefulness of AQP4-Ab titration to predict relapses is limited.

  14. Titrating Oxygen Requirements During Exercise: Evaluation of a Standardized Single Walk Test Protocol.

    PubMed

    Giovacchini, Coral X; Mathews, Anne M; Lawlor, Brian R; MacIntyre, Neil R

    2018-04-01

    Oxygen supplementation for exercise-induced hypoxemia is a common clinical practice that improves exercise tolerance. However, we know of no standardized exercise oxygen titration protocol using a single walk test. We report our experience with a protocol developed in our laboratory. Our protocol is based on the 6-min walk test (6MWT). Pulse oximetry readings (oxygen saturation [Spo 2 ]) are monitored, and supplemental oxygen is added in 2 L/min increments to keep Spo 2 > 88%. This continues for at least 6 min of walking with the Spo 2 remaining > 88% for at least 3 min. The records of consecutive patients over 4 months undergoing this procedure were reviewed for test performance, oxygen titration results, and adverse events. Two hundred twenty-two patients were tested; only two prematurely terminated the protocol because of intractable dyspnea. One hundred fifty-six patients (38%) required oxygen supplementation, with the first titration most commonly occurring between 1 and 2 min of walking. Nine of the patients had the first titration after 5 min of walking. The average test duration was 7 min (maximum, 15 min). The average number of titrations was 2.2 (maximum six). Sixteen patients could not maintain Spo 2 > 88% for 3 min despite administration of 15 L/min of supplemental oxygen (maximal dose). Our protocol was easily performed as a modification of a standard 6MWT with no serious adverse events. Because it is based on a widely accepted measurement of functional capabilities, and because it determined a stable final oxygen dose for ≥ 3 min of walking in most patients, we believe this protocol can be easily adapted for clinical use. Copyright © 2017 American College of Chest Physicians. Published by Elsevier Inc. All rights reserved.

  15. A clean photometric method for the determination of losartan potassium in pharmaceuticals exploiting light scattering effect and employing a multicommuted flow analysis approach.

    PubMed

    Lima, Manoel J A; Reis, Boaventura F

    2017-03-01

    This paper describes an environmentally friendly procedure for the determination of losartan potassium (Los-K) in pharmaceuticals. The photometric method was based on the light scattering effect due to particles suspension, which were formed by the reaction of Los-K with Cu (II) ions. The method was automated employing a multicommuted flow analysis approach, implemented using solenoid mini-pumps for fluid propelling and a homemade LED based photometer. Under the optimized experimental conditions, the procedure showed a linear relationship in the concentration range of 23.2-417.6mgL -1 (r=0.9997, n=6), a relative standard deviation of 1.61% (n=10), a limit of detection (3.3*σ) estimated to be 12.1mgL -1 , and a sampling rate of 140 determinations per hour. Each determination consumed 12µg of copper (II) acetate and generated 0.54mL of waste. Copyright © 2016 Elsevier B.V. All rights reserved.

  16. Assessment of two theoretical methods to estimate potentiometric titration curves of peptides: comparison with experiment.

    PubMed

    Makowska, Joanna; Bagiñska, Katarzyna; Makowski, Mariusz; Jagielska, Anna; Liwo, Adam; Kasprzykowski, Franciszek; Chmurzyñski, Lech; Scheraga, Harold A

    2006-03-09

    We compared the ability of two theoretical methods of pH-dependent conformational calculations to reproduce experimental potentiometric titration curves of two models of peptides: Ac-K5-NHMe in 95% methanol (MeOH)/5% water mixture and Ac-XX(A)7OO-NH2 (XAO) (where X is diaminobutyric acid, A is alanine, and O is ornithine) in water, methanol (MeOH), and dimethyl sulfoxide (DMSO), respectively. The titration curve of the former was taken from the literature, and the curve of the latter was determined in this work. The first theoretical method involves a conformational search using the electrostatically driven Monte Carlo (EDMC) method with a low-cost energy function (ECEPP/3 plus the SRFOPT surface-solvation model, assumming that all titratable groups are uncharged) and subsequent reevaluation of the free energy at a given pH with the Poisson-Boltzmann equation, considering variable protonation states. In the second procedure, molecular dynamics (MD) simulations are run with the AMBER force field and the generalized Born model of electrostatic solvation, and the protonation states are sampled during constant-pH MD runs. In all three solvents, the first pKa of XAO is strongly downshifted compared to the value for the reference compounds (ethylamine and propylamine, respectively); the water and methanol curves have one, and the DMSO curve has two jumps characteristic of remarkable differences in the dissociation constants of acidic groups. The predicted titration curves of Ac-K5-NHMe are in good agreement with the experimental ones; better agreement is achieved with the MD-based method. The titration curves of XAO in methanol and DMSO, calculated using the MD-based approach, trace the shape of the experimental curves, reproducing the pH jump, while those calculated with the EDMC-based approach and the titration curve in water calculated using the MD-based approach have smooth shapes characteristic of the titration of weak multifunctional acids with small differences between the dissociation constants. Nevertheless, quantitative agreement between theoretically predicted and experimental titration curves is not achieved in all three solvents even with the MD-based approach, which is manifested by a smaller pH range of the calculated titration curves with respect to the experimental curves. The poorer agreement obtained for water than for the nonaqueous solvents suggests a significant role of specific solvation in water, which cannot be accounted for by the mean-field solvation models.

  17. Determination of vanadium(V) by direct automatic potentiometric titration with EDTA using a chemically modified electrode as a potentiometric sensor.

    PubMed

    Quintar, S E; Santagata, J P; Cortinez, V A

    2005-10-15

    A chemically modified electrode (CME) was prepared and studied as a potentiometric sensor for the end-point detection in the automatic titration of vanadium(V) with EDTA. The CME was constructed with a paste prepared by mixing spectral-grade graphite powder, Nujol oil and N-2-naphthoyl-N-p-tolylhydroxamic acid (NTHA). Buffer systems, pH effects and the concentration range were studied. Interference ions were separated by applying a liquid-liquid extraction procedure. The CME did not require any special conditioning before using. The electrode was constructed with very inexpensive materials and was easily made. It could be continuously used, at least two months without removing the paste. Automatic potentiometric titration curves were obtained for V(V) within 5 x 10(-5) to 2 x 10(-3)M with acceptable accuracy and precision. The developed method was applied to V(V) determination in alloys for hip prosthesis.

  18. Electrophoretic separation of alginic sodium diester and sodium hexametaphosphate in chondroitin sulfate that interfere with the cetylpyridinium chloride titration assay.

    PubMed

    Weiguo, Zhang; Giancaspro, Gabriel; Adams, Kristie M; Neal-Kababick, James; Hildreth, Jana; Li, Aishan; Roman, Mark C; Betz, Joseph M

    2014-01-01

    The most commonly used chondroitin sulfate (CS) assay method is cetylpyridinium chloride (CPC) titration. Cellulose acetate membrane electrophoresis (CAME) is the technique used for detection of impurities in the U.S. Pharmacopeia's CS monograph. Because CPC titration is a relatively nonspecific quantitative technique, the apparent amount of CS as determined by CPC titration alone may not reflect the true amount of CS due to possible interference with the CPC assay by impurities that contain CPC titratable functional groups. When CAME is used in conjunction with CPC titration, certain non-CS and adulterants can be visualized and estimated, and a true value for CS can be assigned once the presence of these non-CS impurities has been ruled out. This study examines conjunct application of CPC and CAME in ascertaining CS assay and purity in the presence of certain adulterants. These include propylene glycol alginate sulfate sodium, known in commerce as alginic sodium diester (ASD), and Zero One (Z1), a water-soluble agent newly reported in the CS marketplace and subsequently identified as sodium hexametaphosphate. ASD, Z1, and CS are similar in physical appearance and solubility in water and ethanol. They are also titratable anions and form ionic pairs with CPC, therefore interfering with the CPC titration assay for CS CAME separates these adulterants from each other and from CS by differences in their electrophoretic mobility. CAME is able to detect these impurities in CS at levels as low as 0.66% by weight. Although it is recommended that a method for detecting impurities (e.g., CAME) be used in cormbination with relatively nonspecific assay methods such as CPC titration, this is seldom done in practice. Assay results for CS derived fromn CPC titration may, therefore, be misleading, leaving the CS supply chain vulnerable to adulteration. In this study, the authors investigated ASD and Z1 adulteration of CS and developed an electrophoretic separation of these adulterants in CS and procedures to isolate ASD from CS matrixes containing these adulterants. The authors describe in this paper utilization of an orthogonal approach to establish the identity of Z1 as sodium hexametaphosphate and to confirm the identity of ASD, including ethanol fractionation, FTIR spectroscopy, differential scanning calorimetry, and NMR spectroscopy. The authors suggest that CAME is a cost-effective and easy to use methodfor detecting certain impurities in CS raw ingredients and recommend that CPC and CAME be used in combination by QC laboratories as a means of effectively deterring the practice of adulterating CS raw materials with the known adulterants ASD and Z1 and/or other non-chondroitin substances that can be separated from CSby CAME and that exhibit CPC titration behavior similar to CS.

  19. Methods for collection and analysis of geopressured geothermal and oil field waters

    USGS Publications Warehouse

    Lico, Michael S.; Kharaka, Yousif K.; Carothers, William W.; Wright, Victoria A.

    1982-01-01

    Present methods are described for the collection, preservation, and chemical analysis of waters produced from geopressured geothermal and petroleum wells. Detailed procedures for collection include precautions and equipment necessary to ensure that the sample is representative of the water produced. Procedures for sample preservation include filtration, acidification, dilution for silica, methyl isobutyl ketone (MIBK) extraction of aluminum, addition of potassium permanganate to preserve mercury, and precipitation of carbonate species as strontium carbonate for stable carbon isotopes and total dissolved carbonate analysis. Characteristics determined at the well site are sulfide, pH, ammonia, and conductivity. Laboratory procedures are given for the analysis of lithium, sodium, potassium, rubidium, cesium, magnesium, calcium, strontium, barium, iron, manganese, zinc, lead, aluminum, .and mercury by atomic absorption and flame emission spectroscopy. Chloride is determined by silver nitrate titration and fluoride by ion-specific electrode. Bromide and iodide concentrations are determined by the hypochlorite oxidation method. Sulfate is analyzed by titration using barium chloride with thorin indicator after pretreatment with alumina. Boron and silica are determined colorimetrically by the carmine and molybdate-blue methods, respectively. Aliphatic acid anions (C2 through C5) are determined by gas chromatography after separation and concentration in a chloroform-butanol mixture.

  20. Concentration-related response potentiometric titrations to study the interaction of small molecules with large biomolecules.

    PubMed

    Hamidi-Asl, Ezat; Daems, Devin; De Wael, Karolien; Van Camp, Guy; Nagels, Luc J

    2014-12-16

    In the present paper, the utility of a special potentiometric titration approach for recognition and calculation of biomolecule/small-molecule interactions is reported. This approach is fast, sensitive, reproducible, and inexpensive in comparison to the other methods for the determination of the association constant values (Ka) and the interaction energies (ΔG). The potentiometric titration measurement is based on the use of a classical polymeric membrane indicator electrode in a solution of the small-molecule ligand. The biomolecule is used as a titrant. The potential is measured versus a reference electrode and transformed into a concentration-related signal over the entire concentration interval, also at low concentrations, where the millivolt (y-axis) versus log canalyte (x-axis) potentiometric calibration curve is not linear. In the procedure, Ka is calculated for the interaction of cocaine with a cocaine binding aptamer and with an anticocaine antibody. To study the selectivity and cross-reactivity, other oligonucleotides and aptamers are tested, as well as other small ligand molecules such as tetrakis(4-chlorophenyl)borate, metergoline, lidocaine, and bromhexine. The calculated Ka compared favorably to the value reported in the literature using surface plasmon resonance. The potentiometric titration approach called "concentration-related response potentiometry" is used to study molecular interaction for seven macromolecular target molecules and four small-molecule ligands.

  1. High-precision reflectivity measurements: improvements in the calibration procedure

    NASA Astrophysics Data System (ADS)

    Jupe, Marco; Grossmann, Florian; Starke, Kai; Ristau, Detlev

    2003-05-01

    The development of high quality optical components is heavily depending on precise characterization procedures. The reflectance and transmittance of laser components are the most important parameters for advanced laser applications. In the industrial fabrication of optical coatings, quality management is generally insured by spectral photometric methods according to ISO/DIS 15386 on a medium level of accuracy. Especially for high reflecting mirrors, a severe discrepancy in the determination of the absolute reflectivity can be found for spectral photometric procedures. In the first part of the CHOCLAB project, a method for measuring reflectance and transmittance with an enhanced precision was developed, which is described in ISO/WD 13697. In the second part of the CHOCLAB project, the evaluation and optimization for the presented method is scheduled. Within this framework international Round-Robin experiment is currently in progress. During this Round-Robin experiment, distinct deviations could be observed between the results of high precision measurement facilities of different partners. Based on the extended experiments, the inhomogeneity of the sample reflectivity was identified as one important origin for the deviation. Consequently, this inhomogeneity is also influencing the calibration procedure. Therefore, a method was developed that allows the calibration of the chopper blade using always the same position on the reference mirror. During the investigations, the homogeneity of several samples was characterized by a surface mapping procedure for 1064 nm. The measurement facility was extended to the additional wavelength 532 nm and a similar set-up was assembled at 10.6 μm. The high precision reflectivity procedure at the mentioned wavelengths is demonstrated for exemplary measurements.

  2. In situ synthesis, photometric and spectroscopic studies of chelating system during the 1,4,7,10,13,16-hexaoxacyclooctadecane charge transfer reaction with different acceptors

    NASA Astrophysics Data System (ADS)

    Hossan, Aisha S. M.; Abou-Melha, Hanaa M.; Refat, Moamen S.

    2011-08-01

    Electron donor acceptor complexes (EDA) of the 1,4,7,10,13,16-hexaoxacyclooctadecane (18-crown-6) as a rich donor were spectrophotometrically discussed and synthesized in solid form according the interactions with different nine of usual π-acceptors like 2,3,5,6-tetrachlorocyclohexa-2,5-diene-1,4-dione (p-chloranil; p-CHL), tetrachloro-1,2-benzoquinone (o-chloranil; o-CHL), 2,3-dichloro-5,6-dicyano-1,4-benzoquinone (DDQ), tetracyanoquinodimethane (TCNQ), 2,6-dichloroquinone-4-chloroimide (DCQ), 2,6-dibromoquinone-4-chloroimide (DBQ), 2,5-dichloro-3,6-dihydroxy-1,4-benzoquinone (chloranilic acid; CLA), N-bromosuccinimide (NBS), 2,4,6-trinitrophenol (picric acid; PA). Spectroscopic and physical data such as formation constant ( KCT), molar extinction coefficient ( ɛCT), standard free energy (Δ G°), oscillator strength ( f), transition dipole moment ( μ), resonance energy ( RN) and ionization potential ( Ip) were estimated in chloroform or methanol at 25 °C. Based on the elemental analysis and photometric titrations the CT-complexes were formed indicated the formation of 1:1 charge-transfer complexes for the o-CHL, TCNQ, DCQ, DBQ and NBS acceptors but 1:3 ratio for p-CHL, DDQ, CLA and PA, respectively. The charge-transfer interactions were interpretative according to the formation of dative ion pairs [18C6 rad +, A rad -], where A is acceptor. All of the resulting charge transfer complexes were isolated in amorphous form and the complexes formations on IR and 1H NMR spectra were discussed.

  3. Light Reflection from Packed Layers of Transparent Spheres: Is Hapke's Photometric Model Accurate Enough to Make Predictions?

    NASA Astrophysics Data System (ADS)

    Zhang, H.; Voss, K. J.

    2011-03-01

    We demonstrate that the diffraction removal procedure outlined by Hapke et al. [Icarus, 199, 210 (2009)] contains an error. By following their intended scheme we found that the Hapke model is not anisotropic enough to describe the reflectance patterns.

  4. Thermodynamic Insight into the Solvation and Complexation Behavior of U(VI) in Ionic Liquid: Binding of CMPO with U(VI) Studied by Optical Spectroscopy and Calorimetry.

    PubMed

    Wu, Qi; Sun, Taoxiang; Meng, Xianghai; Chen, Jing; Xu, Chao

    2017-03-06

    The complexation of U(VI) with octylphenyl-N,N-diisobutylcarbamoylmethylphosphine oxide (CMPO, denoted as L) in ionic liquid (IL) C 4 mimNTf 2 was investigated by UV-vis absorption spectrophotometry and isothermal titration calorimetry. Spectro-photometric titration suggests that three successive complexes, UO 2 L j 2+ (j = 1-3), formed both in "dry" (water content < 250 ppm) and "wet" (water content ≈ 12 500 ppm) ionic liquid. However, the thermodynamic parameters are distinctly different in the two ILs. In dry IL, the complexation strength between CMPO and U(VI) is much stronger, with stability constants of the respective complexes more than 1 order of magnitude higher than that in wet IL. Energetically, the complexation of U(VI) with CMPO in dry IL is mainly driven by negative enthalpies. In contrast, the complexation in wet IL is overwhelmingly driven by highly positive entropies as a result of the release of a large amount of water molecules from the solvation sphere of U(VI). Moreover, comparisons between the fitted absorption spectra of complexes in wet IL and that of extractive samples from solvent extraction have identified the speciation involved in the extraction of U(VI) by CMPO in ionic liquid. The results from this study not only offer a thermodynamic insight into the complexation behavior of U(VI) with CMPO in IL but also provide valuable information for understanding the extraction behavior in the corresponding solvent extraction system.

  5. Titrimetric Determination of Carbon Dioxide in a Heterogeneous Sample ("Pop Rocks")

    NASA Astrophysics Data System (ADS)

    Davis, Craig M.; Mauck, Matthew C.

    2003-05-01

    A traditional exercise in quantitative analysis is the titration of mixtures of sodium hydroxide, sodium carbonate, and sodium bicarbonate. Often, consumer products are studied. A procedure to analyze the total volume of carbon dioxide bubbles in the candy "Pop Rocks" is presented. The popularity of the sample and the simplicity of the procedure make this exercise suitable for a wide variety of students: from non-science majors to chemistry majors in a quantitative analysis course.

  6. Determination of Ammonia in Household Cleaners: An Instrumental Analysis Experiment.

    ERIC Educational Resources Information Center

    Graham, Richard C.; DePew, Steven

    1983-01-01

    Briefly discusses three techniques for assessing amount of ammonia present in household cleaners. Because of disadvantages with these methods, the thermometric titration technique is suggested in which students judge the best buy based on relative cost of ammonia present in samples. Laboratory procedures, typical results, and reactions involved…

  7. Risky Choice in Pigeons and Humans: A Cross-Species Comparison

    ERIC Educational Resources Information Center

    Lagorio, Carla H.; Hackenberg, Timothy D.

    2010-01-01

    Pigeon and human subjects were given repeated choices between variable and adjusting delays to token reinforcement that titrated in relation to a subject's recent choice patterns. Indifference curves were generated under two different procedures: "immediate exchange," in which a token earned during each trial was exchanged immediately for access…

  8. Oxygen from Hydrogen Peroxide. A Safe Molar Volume-Molar Mass Experiment.

    ERIC Educational Resources Information Center

    Bedenbaugh, John H.; And Others

    1988-01-01

    Describes a molar volume-molar mass experiment for use in general chemistry laboratories. Gives background technical information, procedures for the titration of aqueous hydrogen peroxide with standard potassium permanganate and catalytic decomposition of hydrogen peroxide to produce oxygen, and a discussion of the results obtained in three…

  9. 21 CFR 172.133 - Dimethyl dicarbonate.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ..., analytical-grade Solution of 1 N diisobutylamine in chlorobenzene, distilled 1 N Acetic Acid procedure... the 1 N diisobutylamine solution by pipette and allow to stand for 5 minutes. Subsequently, titrate...). calculation ER10MR99.023 Note: For adding the diisobutylamine solution, always use the same pipette and wait...

  10. 21 CFR 172.133 - Dimethyl dicarbonate.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ..., analytical-grade Solution of 1 N diisobutylamine in chlorobenzene, distilled 1 N Acetic Acid procedure... the 1 N diisobutylamine solution by pipette and allow to stand for 5 minutes. Subsequently, titrate...). calculation ER10MR99.023 Note: For adding the diisobutylamine solution, always use the same pipette and wait...

  11. Assessment of two theoretical methods to estimate potentiometrictitration curves of peptides: comparison with experiment

    PubMed Central

    Makowska, Joanna; Bagiñska, Katarzyna; Makowski, Mariusz; Jagielska, Anna; Liwo, Adam; Kasprzykowski, Franciszek; Chmurzyñski, Lech; Scheraga, Harold A.

    2008-01-01

    We compared the ability of two theoretical methods of pH-dependent conformational calculations to reproduce experimental potentiometric-titration curves of two models of peptides: Ac-K5-NHMe in 95% methanol (MeOH)/5% water mixture and Ac-XX(A)7OO-NH2 (XAO) (where X is diaminobutyric acid, A is alanine, and O is ornithine) in water, methanol (MeOH) and dimethylsulfoxide (DMSO), respectively. The titration curve of the former was taken from the literature, and the curve of the latter was determined in this work. The first theoretical method involves a conformational search using the Electrostatically Driven Monte Carlo (EDMC) method with a low-cost energy function (ECEPP/3 plus the SRFOPT surface-solvation model, assumming that all titratable groups are uncharged) and subsequent reevaluation of the free energy at a given pH with the Poisson-Boltzmann equation, considering variable protonation states. In the second procedure, MD simulations are run with the AMBER force field and the Generalized-Born model of electrostatic solvation, and the protonation states are sampled during constant-pH MD runs. In all three solvents, the first pKa of XAO is strongly downshifted compared to the value for the reference compounds (ethyl amine and propyl amine, respectively); the water and methanol curves have one, and the DMSO curve has two jumps characteristic of remarkable differences in the dissociation constants of acidic groups. The predicted titration curves of Ac-K5-NHMe are in good agreement with the experimental ones; better agreement is achieved with the MD-based method. The titration curves of XAO in methanol and DMSO, calculated using the MD-based approach, trace the shape of the experimental curves, reproducing the pH jump, while those calculated with the EDMC-based approach, and the titration curve in water calculated using the MD-based approach, have smooth shapes characteristic of the titration of weak multifunctional acids with small differences between the dissociation constants. Nevertheless, quantitative agreement between theoretically predicted and experimental titration curves is not achieved in all three solvents even with the MD-based approach which is manifested by a smaller pH range of the calculated titration curves with respect to the experimental curves. The poorer agreement obtained for water than for the non-aqueous solvents suggests a significant role of specific solvation in water, which cannot be accounted for by the mean-field solvation models. PMID:16509748

  12. Dark Energy Survey Year 1 Results: Cross-Correlation Redshifts - Methods and Systematics Characterization

    DOE PAGES

    Gatti, M.

    2018-02-22

    We use numerical simulations to characterize the performance of a clustering-based method to calibrate photometric redshift biases. In particular, we cross-correlate the weak lensing (WL) source galaxies from the Dark Energy Survey Year 1 (DES Y1) sample with redMaGiC galaxies (luminous red galaxies with secure photometric red- shifts) to estimate the redshift distribution of the former sample. The recovered redshift distributions are used to calibrate the photometric redshift bias of standard photo-z methods applied to the same source galaxy sample. We also apply the method to three photo-z codes run in our simulated data: Bayesian Photometric Redshift (BPZ), Directional Neighborhoodmore » Fitting (DNF), and Random Forest-based photo-z (RF). We characterize the systematic uncertainties of our calibration procedure, and find that these systematic uncertainties dominate our error budget. The dominant systematics are due to our assumption of unevolving bias and clustering across each redshift bin, and to differences between the shapes of the redshift distributions derived by clustering vs photo-z's. The systematic uncertainty in the mean redshift bias of the source galaxy sample is z ≲ 0.02, though the precise value depends on the redshift bin under consideration. Here, we discuss possible ways to mitigate the impact of our dominant systematics in future analyses.« less

  13. Dark Energy Survey Year 1 Results: Cross-Correlation Redshifts - Methods and Systematics Characterization

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gatti, M.

    We use numerical simulations to characterize the performance of a clustering-based method to calibrate photometric redshift biases. In particular, we cross-correlate the weak lensing (WL) source galaxies from the Dark Energy Survey Year 1 (DES Y1) sample with redMaGiC galaxies (luminous red galaxies with secure photometric red- shifts) to estimate the redshift distribution of the former sample. The recovered redshift distributions are used to calibrate the photometric redshift bias of standard photo-z methods applied to the same source galaxy sample. We also apply the method to three photo-z codes run in our simulated data: Bayesian Photometric Redshift (BPZ), Directional Neighborhoodmore » Fitting (DNF), and Random Forest-based photo-z (RF). We characterize the systematic uncertainties of our calibration procedure, and find that these systematic uncertainties dominate our error budget. The dominant systematics are due to our assumption of unevolving bias and clustering across each redshift bin, and to differences between the shapes of the redshift distributions derived by clustering vs photo-z's. The systematic uncertainty in the mean redshift bias of the source galaxy sample is z ≲ 0.02, though the precise value depends on the redshift bin under consideration. Here, we discuss possible ways to mitigate the impact of our dominant systematics in future analyses.« less

  14. Dark Energy Survey Year 1 Results: Calibration of redMaGiC Redshift Distributions in DES and SDSS from Cross-Correlations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cawthon, R.; et al.

    We present calibrations of the redshift distributions of redMaGiC galaxies in the Dark Energy Survey Year 1 (DES Y1) and Sloan Digital Sky Survey (SDSS) DR8 data. These results determine the priors of the redshift distribution of redMaGiC galaxies, which were used for galaxy clustering measurements and as lenses for galaxy-galaxy lensing measurements in DES Y1 cosmological analyses. We empirically determine the bias in redMaGiC photometric redshift estimates using angular cross-correlations with Baryon Oscillation Spectroscopic Survey (BOSS) galaxies. For DES, we calibrate a single parameter redshift bias in three photometric redshift bins:more » $$z \\in[0.15,0.3]$$, [0.3,0.45], and [0.45,0.6]. Our best fit results in each bin give photometric redshift biases of $$|\\Delta z|<0.01$$. To further test the redMaGiC algorithm, we apply our calibration procedure to SDSS redMaGiC galaxies, where the statistical precision of the cross-correlation measurement is much higher due to a greater overlap with BOSS galaxies. For SDSS, we also find best fit results of $$|\\Delta z|<0.01$$. We compare our results to other analyses of redMaGiC photometric redshifts.« less

  15. Photometric Characterization of the Dark Energy Camera

    DOE PAGES

    Bernstein, G. M.; Abbott, T. M. C.; Armstrong, R.; ...

    2018-04-02

    We characterize the variation in photometric response of the Dark Energy Camera (DECam) across its 520 Mpix science array during 4 years of operation. These variations are measured using high signal-to-noise aperture photometry of >10 7 stellar images in thousands of exposures of a few selected fields, with the telescope dithered to move the sources around the array. A calibration procedure based on these results brings the rms variation in aperture magnitudes of bright stars on cloudless nights down to 2–3 mmag, with <1 mmag of correlated photometric errors for stars separated by ≥20''. On cloudless nights, any departures ofmore » the exposure zeropoints from a secant airmass law exceeding 1 mmag are plausibly attributable to spatial/temporal variations in aperture corrections. These variations can be inferred and corrected by measuring the fraction of stellar light in an annulus between 6'' and 8'' diameter. Key elements of this calibration include: correction of amplifier nonlinearities; distinguishing pixel-area variations and stray light from quantum-efficiency variations in the flat fields; field-dependent color corrections; and the use of an aperture-correction proxy. The DECam response pattern across the 2° field drifts over months by up to ±9 mmag, in a nearly wavelength-independent low-order pattern. Here, we find no fundamental barriers to pushing global photometric calibrations toward mmag accuracy.« less

  16. An imaging-based photometric and colorimetric measurement method for characterizing OLED panels for lighting applications

    NASA Astrophysics Data System (ADS)

    Zhu, Yiting; Narendran, Nadarajah; Tan, Jianchuan; Mou, Xi

    2014-09-01

    The organic light-emitting diode (OLED) has demonstrated its novelty in displays and certain lighting applications. Similar to white light-emitting diode (LED) technology, it also holds the promise of saving energy. Even though the luminous efficacy values of OLED products have been steadily growing, their longevity is still not well understood. Furthermore, currently there is no industry standard for photometric and colorimetric testing, short and long term, of OLEDs. Each OLED manufacturer tests its OLED panels under different electrical and thermal conditions using different measurement methods. In this study, an imaging-based photometric and colorimetric measurement method for OLED panels was investigated. Unlike an LED that can be considered as a point source, the OLED is a large form area source. Therefore, for an area source to satisfy lighting application needs, it is important that it maintains uniform light level and color properties across the emitting surface of the panel over a long period. This study intended to develop a measurement procedure that can be used to test long-term photometric and colorimetric properties of OLED panels. The objective was to better understand how test parameters such as drive current or luminance and temperature affect the degradation rate. In addition, this study investigated whether data interpolation could allow for determination of degradation and lifetime, L70, at application conditions based on the degradation rates measured at different operating conditions.

  17. Photometric Characterization of the Dark Energy Camera

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bernstein, G. M.; Abbott, T. M. C.; Armstrong, R.

    We characterize the variation in photometric response of the Dark Energy Camera (DECam) across its 520 Mpix science array during 4 years of operation. These variations are measured using high signal-to-noise aperture photometry of >10 7 stellar images in thousands of exposures of a few selected fields, with the telescope dithered to move the sources around the array. A calibration procedure based on these results brings the rms variation in aperture magnitudes of bright stars on cloudless nights down to 2–3 mmag, with <1 mmag of correlated photometric errors for stars separated by ≥20''. On cloudless nights, any departures ofmore » the exposure zeropoints from a secant airmass law exceeding 1 mmag are plausibly attributable to spatial/temporal variations in aperture corrections. These variations can be inferred and corrected by measuring the fraction of stellar light in an annulus between 6'' and 8'' diameter. Key elements of this calibration include: correction of amplifier nonlinearities; distinguishing pixel-area variations and stray light from quantum-efficiency variations in the flat fields; field-dependent color corrections; and the use of an aperture-correction proxy. The DECam response pattern across the 2° field drifts over months by up to ±9 mmag, in a nearly wavelength-independent low-order pattern. Here, we find no fundamental barriers to pushing global photometric calibrations toward mmag accuracy.« less

  18. Photometric Characterization of the Dark Energy Camera

    NASA Astrophysics Data System (ADS)

    Bernstein, G. M.; Abbott, T. M. C.; Armstrong, R.; Burke, D. L.; Diehl, H. T.; Gruendl, R. A.; Johnson, M. D.; Li, T. S.; Rykoff, E. S.; Walker, A. R.; Wester, W.; Yanny, B.

    2018-05-01

    We characterize the variation in photometric response of the Dark Energy Camera (DECam) across its 520 Mpix science array during 4 years of operation. These variations are measured using high signal-to-noise aperture photometry of >107 stellar images in thousands of exposures of a few selected fields, with the telescope dithered to move the sources around the array. A calibration procedure based on these results brings the rms variation in aperture magnitudes of bright stars on cloudless nights down to 2–3 mmag, with <1 mmag of correlated photometric errors for stars separated by ≥20″. On cloudless nights, any departures of the exposure zeropoints from a secant airmass law exceeding 1 mmag are plausibly attributable to spatial/temporal variations in aperture corrections. These variations can be inferred and corrected by measuring the fraction of stellar light in an annulus between 6″ and 8″ diameter. Key elements of this calibration include: correction of amplifier nonlinearities; distinguishing pixel-area variations and stray light from quantum-efficiency variations in the flat fields; field-dependent color corrections; and the use of an aperture-correction proxy. The DECam response pattern across the 2° field drifts over months by up to ±9 mmag, in a nearly wavelength-independent low-order pattern. We find no fundamental barriers to pushing global photometric calibrations toward mmag accuracy.

  19. A cooperative approach among methods for photometric redshifts estimation: an application to KiDS data

    NASA Astrophysics Data System (ADS)

    Cavuoti, S.; Tortora, C.; Brescia, M.; Longo, G.; Radovich, M.; Napolitano, N. R.; Amaro, V.; Vellucci, C.; La Barbera, F.; Getman, F.; Grado, A.

    2017-04-01

    Photometric redshifts (photo-z) are fundamental in galaxy surveys to address different topics, from gravitational lensing and dark matter distribution to galaxy evolution. The Kilo Degree Survey (KiDS), I.e. the European Southern Observatory (ESO) public survey on the VLT Survey Telescope (VST), provides the unprecedented opportunity to exploit a large galaxy data set with an exceptional image quality and depth in the optical wavebands. Using a KiDS subset of about 25000 galaxies with measured spectroscopic redshifts, we have derived photo-z using (I) three different empirical methods based on supervised machine learning; (II) the Bayesian photometric redshift model (or BPZ); and (III) a classical spectral energy distribution (SED) template fitting procedure (LE PHARE). We confirm that, in the regions of the photometric parameter space properly sampled by the spectroscopic templates, machine learning methods provide better redshift estimates, with a lower scatter and a smaller fraction of outliers. SED fitting techniques, however, provide useful information on the galaxy spectral type, which can be effectively used to constrain systematic errors and to better characterize potential catastrophic outliers. Such classification is then used to specialize the training of regression machine learning models, by demonstrating that a hybrid approach, involving SED fitting and machine learning in a single collaborative framework, can be effectively used to improve the accuracy of photo-z estimates.

  20. The Gaia mission status

    NASA Astrophysics Data System (ADS)

    Prusti, T.

    2018-04-01

    Gaia is an ESA cornerstone mission conducting a full sky survey over its 5 year operational period. Gaia performs astrometric, photometric and spectroscopic measurements. The data processing is entrusted to scientists and engineers who have formed the Gaia Data Processing and Analysis Consortium (DPAC). The photometric science alerts started in 2014. The first intermediate data release (Gaia DR1) took place 14 September 2016 and it has been extensively used by the community. Gaia DR2 is scheduled for April 2018. Gaia is expected to be able to continue observations roughly for another 5 years after the nominal phase. The procedure to grant funding for the extension period has been initiated. In case funding is granted, the total operational time of Gaia may be 10 years.

  1. A photometric mode identification method, including an improved non-adiabatic treatment of the atmosphere

    NASA Astrophysics Data System (ADS)

    Dupret, M.-A.; De Ridder, J.; De Cat, P.; Aerts, C.; Scuflaire, R.; Noels, A.; Thoul, A.

    2003-02-01

    We present an improved version of the method of photometric mode identification of Heynderickx et al. (\\cite{hey}). Our new version is based on the inclusion of precise non-adiabatic eigenfunctions determined in the outer stellar atmosphere according to the formalism recently proposed by Dupret et al. (\\cite{dup}). Our improved photometric mode identification technique is therefore no longer dependent on ad hoc parameters for the non-adiabatic effects. It contains the complete physical conditions of the outer atmosphere of the star, provided that rotation does not play a key role. We apply our method to the two slowly pulsating B stars HD 74560 and HD 138764 and to the beta Cephei star EN (16) Lac. Besides identifying the degree l of the pulsating stars, our method is also a tool for improving the knowledge of stellar interiors and atmospheres, by imposing constraints on parameters such as the metallicity and the mixing-length parameter alpha (a procedure we label non-adiabatic asteroseismology). The non-adiabatic eigenfunctions needed for the mode identification are available upon request from the authors.

  2. 77 FR 21038 - Energy Conservation Program: Test Procedures for Light-Emitting Diode Lamps

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-04-09

    ... Photometric Measurements of Solid-State Lighting Products'' for determining lumen output, input power, and CCT.... Test Method 5. Test Calculations and Rounding C. Proposed Approach for Rated Lifetime Measurements 1... Test Method to Project Rated Lifetime 4. Test Conditions 5. Test Setup 6. Test Method and Measurements...

  3. A Device to Demonstrate the Principles of Photometry and Three Experiments for Its Use.

    ERIC Educational Resources Information Center

    Delumyea, R. Del

    1987-01-01

    Describes how to construct a simple photometer. Outlines experiments in which this device can be used to demonstrate basic electronic principles, the use of Beer's Law to determine the concentration of an analyte in solution, and the effect of molar absorptivity on the sensitivity of photometric procedures. (TW)

  4. A field method for the determination of calcium and magnesium in limestone and dolomite

    USGS Publications Warehouse

    Shapiro, Leonard; Brannock, Walter Wallace

    1957-01-01

    The method is an adaptation of a procedure described by Betz and Noll1 in 1950. Calcium and magnesium are determined by visual titration using Versene (disodium ethylenediamine tetraacetate) with Murexide (ammonium purpurate) as the indicator for calcium and Eriochrome Black T as the indicator for magnesium.

  5. A photometric method for the estimation of the oil yield of oil shale

    USGS Publications Warehouse

    Cuttitta, Frank

    1951-01-01

    A method is presented for the distillation and photometric estimation of the oil yield of oil-bearing shales. The oil shale is distilled in a closed test tube and the oil extracted with toluene. The optical density of the toluene extract is used in the estimation of oil content and is converted to percentage of oil by reference to a standard curve. This curve is obtained by relating the oil yields determined by the Fischer assay method to the optical density of the toluene extract of the oil evolved by the new procedure. The new method gives results similar to those obtained by the Fischer assay method in a much shorter time. The applicability of the new method to oil-bearing shale and phosphatic shale has been tested.

  6. Time-to-isolation guided titration of freeze duration in 3rd generation short-tip cryoballoon pulmonary vein isolation - Comparable clinical outcome and shorter procedure duration.

    PubMed

    Pott, Alexander; Kraft, Christoph; Stephan, Tilman; Petscher, Kerstin; Rottbauer, Wolfgang; Dahme, Tillman

    2018-03-15

    The optimal freeze duration in cryoballoon pulmonary vein isolation (PVI) is unknown. The 3rd generation cryoballoon facilitates observation of the time-to-isolation (TTI) and thereby enables individualized cryoenergy titration. To evaluate the efficacy of an individualized freeze duration we compared the clinical outcome of patients treated with a TTI-guided ablation protocol to the outcome of patients treated with a fixed ablation protocol. We compared 100 patients treated with the 3rd generation cryoballoon applying a TTI-based protocol (TTI group) to 100 patients treated by a fixed freeze protocol (fixed group). In the fixed group a 240s freeze cycle was followed by a 240s bonus freeze after acute PV isolation. In the TTI group freeze duration was 180s if TTI was ≥30s and reduced to only 120s, if TTI was <30s. In case of a TTI >60s a 180s bonus freeze was applied. Freedom from atrial arrhythmia recurrence off class I/III antiarrhythmic drugs after one year was not different between the TTI group (73.6%) and the fixed group (75.7%; p=0.75). Mean procedure duration was 85.8±27.3min in the TTI group compared to 115.7±27.1min in the fixed group (p<0.001). Mean fluoroscopy time was 17.5±6.6min in the TTI group and 22.5±9.8min in the fixed group (p<0.001). TTI-guided cryoenergy titration leads to reduced procedure duration and fluoroscopy time and appears to be as effective as a fixed ablation strategy. A single 2-minute freeze seems to be sufficient in case of short TTI. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.

  7. A Recommended Engineering Application of the Method for Evaluating the Visual Significance of Reflected Glare.

    ERIC Educational Resources Information Center

    Blackwell, H. Richard

    1963-01-01

    An application method for evaluating the visual significance of reflected glare is described, based upon a number of decisions with respect to the relative importance of various aspects of visual performance. A standardized procedure for evaluating the overall effectiveness of lighting from photometric data on materials or installations is needed…

  8. Balanced conscious sedation with intravenous induction and inhalational maintenance for patients requiring endoscopic and/or surgical procedures.

    PubMed

    Lahoud, G Y; Hopkins, P M

    2007-02-01

    The use of inhalation sedation with sub-anaesthetic concentrations of sevoflurane and nitrous oxide mixture is expected to reduce amounts of intravenous sedative drugs needed to produce a balanced sedation with the benefits of having reduced side-effects. Eighty-two patients requiring endoscopic and/or surgical procedures under conscious sedation and local anaesthesia were recruited for this pilot study. Conscious sedation was induced with a titrated dose of midazolam and propofol given intravenously until the clinical end-point of conscious sedation was achieved. Subsequently, during the procedure, the patient was asked to breathe sevoflurane 0.1-0.3% and a fixed ratio of 40% nitrous oxide in oxygen given through a face mask. In 78 patients (95.1%), the treatment was completed successfully. Patients were discharged back to the wards within 4-16 min (10.1) without significant side-effects. Treatment was satisfactorily accepted by 38 patients (48.7%) and considered excellent by 40 patients (51.3%). The use of titrated doses of intravenous sedative drugs for induction of conscious sedation followed by the use of low concentrations (0.1-0.3%) of sevoflurane combined with 40% nitrous oxide for maintenance of conscious sedation in patients requiring endoscopic and/or surgical procedures under local anaesthesia, has the potential advantages of reducing amounts of intravenous sedative drugs, less likelihood of problems from drug side-effects and fast recovery and discharge time. Further investigations to establish the technique are currently in progress.

  9. VizieR Online Data Catalog: GOODS-MUSIC catalog updated version (Santini+, 2009)

    NASA Astrophysics Data System (ADS)

    Santini, P.; Fontana, A.; Grazian, A.; Salimbeni, S.; Fiore, F.; Fontanot, F.; Boutsia, K.; Castelllano, M.; Cristiani, S.; de Santis, C.; Gallozzi, S.; Giallongo, E.; Nonino, M.; Menci, N.; Paris, D.; Pentericci, L.; Vanzella, E.

    2009-06-01

    The GOODS-MUSIC multiwavelength catalog provides photometric and spectroscopic information for galaxies in the GOODS Southern field. It includes two U images obtained with the ESO 2.2m telescope and one U band image from VLT-VIMOS, the ACS-HST images in four optical (B,V,i,z) bands, the VLT-ISAAC J, H, and Ks bands as well as the Spitzer images at 3.6, 4.5, 5.8, and 8 micron (IRAC) and 24 micron (MIPS). Most of these images have been made publicly available in the coadded version by the GOODS team, while the U band data were retrieved in raw format and reduced by our team. We also collected all the available spectroscopic information from public spectroscopic surveys and cross-correlated the spectroscopic redshifts with our photometric catalog. For the unobserved fraction of the objects, we applied our photometric redshift code to obtain well-calibrated photometric redshifts. The final catalog is made up of 15208 objects, with 209 known stars and 61 AGNs. The major new feature of this updated release is the inclusion of 24 micron photometry. Further improvements concern a revised photometry in the four IRAC bands (mainly based on the use of new PSF-matching kernerls and on a revised procedure for estimating the background), the enlargement of the sample of galaxies with spectroscopic redshifts, the addition of objects selected on the IRAC 4.5 micron image and a more careful selection of AGN sources. (1 data file).

  10. Reduction in in vivo testing at the National Veterinary Services Laboratories of the United States Department of Agriculture.

    PubMed

    Hyde, R L

    1986-01-01

    Efforts are being made at the National Veterinary Services Laboratories to reduce in vivo testing of USDA licensed veterinary vaccines. A hemagglutination test for determining potency of killed parvovirus vaccine is currently being used for canine and swine adjuvanted and nonadjuvanted products; a serum neutralization inhibition test (SNIT) is being developed for potency testing of killed adjuvanted infectious bovine rhinotracheitis (IBR), bovine virus diarrhea (BVD) and parainfluenza (PI3) vaccines: and a tissue culture titration method for live avian encephalomyelitis virus vaccine is being pursued as a replacement for the old hatch-out chick embryo titration method. Difficulties in separating the antigen from oil emulsion products are preventing significant advances in developing in vitro testing procedures for poultry killed-virus vaccines.

  11. OmegaWINGS: OmegaCAM-VST observations of WINGS galaxy clusters

    NASA Astrophysics Data System (ADS)

    Gullieuszik, M.; Poggianti, B.; Fasano, G.; Zaggia, S.; Paccagnella, A.; Moretti, A.; Bettoni, D.; D'Onofrio, M.; Couch, W. J.; Vulcani, B.; Fritz, J.; Omizzolo, A.; Baruffolo, A.; Schipani, P.; Capaccioli, M.; Varela, J.

    2015-09-01

    Context. Wide-field observations targeting galaxy clusters at low redshift are complementary to field surveys and provide the local benchmark for detailed studies of the most massive haloes in the local Universe. The Wide-field Nearby Galaxy-cluster Survey (WINGS) is a wide-field multi-wavelength survey of X-ray selected clusters at z = 0.04-0.07. The original 34' × 34' WINGS field of view has now been extended to cover a 1 deg2 field with both photometry and spectroscopy. Aims: We present the Johnson B- and V-band OmegaCAM at the VST observations of 46 WINGS clusters together with the data reduction, data quality, and Sextractor photometric catalogues. Methods: The data reduction was carried out with a modified version of the ESO-MVM (also known as ALAMBIC) reduction package, adding a cross-talk correction, the gain harmonisation, and a control procedure for problematic CCDs. The stray-light component was corrected for by employing our own observations of populated stellar fields. Results: With a median seeing of 1″ in both bands, our 25-min exposures in each band typically reach the 50% completeness level at V = 23.1 mag. The quality of the astrometric and photometric accuracy has been verified by comparison with the 2MASS and SDSS astrometry, and SDSS and previous WINGS imaging. Star-to-galaxy separation and sky-subtraction procedure were tested comparing them with previous WINGS data. Conclusions: The Sextractor photometric catalogues are publicly available at the CDS and will be included in the next release of the WINGS database on the Virtual Observatory together with the OmegaCAM reduced images. These data form the basis for a large ongoing spectroscopic campaign with AAOmega at the AAT and are being employed for a variety of studies. Based on observations made with VST at ESO Paranal Observatory under program ID 88.A-4005, 089.A-0023, 090.A-0074, 091.A-0059, and 093.A-0041.The photometric catalogue is only available at the CDS via anonymous ftp to http://cdsarc.u-strasbg.fr (ftp://130.79.128.5) or via http://cdsarc.u-strasbg.fr/viz-bin/qcat?J/A+A/581/A41

  12. SkZpipe: A Python3 module to produce efficiently PSF-fitting photometry with DAOPHOT, and much more

    NASA Astrophysics Data System (ADS)

    Mauro, F.

    2017-07-01

    In an era characterized by big sky surveys and the availability of large amount of photometric data, it is important for astronomers to have tools to process their data in an efficient, accurate and easy way, minimizing reduction time. We present SkZpipe, a Python3 module designed mainly to process generic data, performing point-spread function (PSF) fitting photometry with the DAOPHOT suite (Stetson 1987). The software has already demonstrated its accuracy and efficiency with the adaptation VVV-SkZ_pipeline (Mauro et al. 2013) for the "VISTA Variables in the Vía Láctea" ESO survey, showing how it can replace the users, avoiding repetitive interaction in all the operations, retaining all of the benefits of the power and accuracy of the DAOPHOT suite, detaching them from the burden of data precessing. This software provides not only a pipeline, but also all the tools to run easily each atomic step of the photometric procedure, to match the results, and to retrieve information from fits headers and the internal instrumental database. We plan to add the support to other photometric softwares in the future.

  13. The Plaque-Antiserum Method: an Assay of Virus Infectivity and an Experimental Model of Virus Infection

    PubMed Central

    De Flora, Silvio

    1974-01-01

    Areas of cytopathic effect can be circumscribed in cell monolayers by adding antiserum to the liquid nutrient medium after adsorption of virus. This procedure represents a simple and reliable tool for the titration of virus infectivity and provides an experimental model for studying some aspects of virus infection. Images PMID:4364462

  14. 7 CFR 58.810 - Temperature requirements.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 3 2012-01-01 2012-01-01 false Temperature requirements. 58.810 Section 58.810... Procedures § 58.810 Temperature requirements. (a) Unless processed within 2 hours, all whey or condensed whey, except acid type whey with a titratable acidity of 0.40 percent or above, or a pH of 4.6 or below, shall...

  15. 7 CFR 58.810 - Temperature requirements.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 3 2014-01-01 2014-01-01 false Temperature requirements. 58.810 Section 58.810... Procedures § 58.810 Temperature requirements. (a) Unless processed within 2 hours, all whey or condensed whey, except acid type whey with a titratable acidity of 0.40 percent or above, or a pH of 4.6 or below, shall...

  16. 7 CFR 58.810 - Temperature requirements.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 3 2011-01-01 2011-01-01 false Temperature requirements. 58.810 Section 58.810... Procedures § 58.810 Temperature requirements. (a) Unless processed within 2 hours, all whey or condensed whey, except acid type whey with a titratable acidity of 0.40 percent or above, or a pH of 4.6 or below, shall...

  17. 7 CFR 58.810 - Temperature requirements.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 3 2013-01-01 2013-01-01 false Temperature requirements. 58.810 Section 58.810... Procedures § 58.810 Temperature requirements. (a) Unless processed within 2 hours, all whey or condensed whey, except acid type whey with a titratable acidity of 0.40 percent or above, or a pH of 4.6 or below, shall...

  18. An Environmental Friendly Procedure for Photometric Determination of Hypochlorite in Tap Water Employing a Miniaturized Multicommuted Flow Analysis Setup

    PubMed Central

    Borges, Sivanildo S.; Reis, Boaventura F.

    2011-01-01

    A photometric procedure for the determination of ClO− in tap water employing a miniaturized multicommuted flow analysis setup and an LED-based photometer is described. The analytical procedure was implemented using leucocrystal violet (LCV; 4,4′,4′′-methylidynetris (N,N-dimethylaniline), C25H31N3) as a chromogenic reagent. Solenoid micropumps employed for solutions propelling were assembled together with the photometer in order to compose a compact unit of small dimensions. After control variables optimization, the system was applied for the determination of ClO− in samples of tap water, and aiming accuracy assessment samples were also analyzed using an independent method. Applying the paired t-test between results obtained using both methods, no significant difference at the 95% confidence level was observed. Other useful features include low reagent consumption, 2.4 μg of LCV per determination, a linear response ranging from 0.02 up to 2.0 mg L−1  ClO−, a relative standard deviation of 1.0% (n = 11) for samples containing 0.2 mg L−1  ClO−, a detection limit of 6.0 μg L−1  ClO−, a sampling throughput of 84 determinations per hour, and a waste generation of 432 μL per determination. PMID:21747732

  19. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Taylor-Pashow, K.; Fondeur, F.; White, T.

    Savannah River National Laboratory (SRNL) was tasked with identifying and developing at least one, but preferably two methods for quantifying the suppressor in the Next Generation Solvent (NGS) system. The suppressor is a guanidine derivative, N,N',N"-tris(3,7-dimethyloctyl)guanidine (TiDG). A list of 10 possible methods was generated, and screening experiments were performed for 8 of the 10 methods. After completion of the screening experiments, the non-aqueous acid-base titration was determined to be the most promising, and was selected for further development as the primary method. {sup 1}H NMR also showed promising results from the screening experiments, and this method was selected formore » further development as the secondary method. Other methods, including {sup 36}Cl radiocounting and ion chromatography, also showed promise; however, due to the similarity to the primary method (titration) and the inability to differentiate between TiDG and TOA (tri-n-ocytlamine) in the blended solvent, {sup 1}H NMR was selected over these methods. Analysis of radioactive samples obtained from real waste ESS (extraction, scrub, strip) testing using the titration method showed good results. Based on these results, the titration method was selected as the method of choice for TiDG measurement. {sup 1}H NMR has been selected as the secondary (back-up) method, and additional work is planned to further develop this method and to verify the method using radioactive samples. Procedures for analyzing radioactive samples of both pure NGS and blended solvent were developed and issued for the both methods.« less

  20. A Sensitive Photometric Procedure for Cobalt Determination in Water Employing a Compact Multicommuted Flow Analysis System.

    PubMed

    da Silva Magalhães, Ticiane; Reis, Boaventura F

    2017-09-01

    In this work, a multicommuted flow analysis procedure is proposed for the spectrophotometric determination of cobalt in fresh water, employing an instrument setup of downsized dimension and improved cost-effectiveness. The method is based on the catalytic effect of Co(II) on the Tiron oxidation by hydrogen peroxide in alkaline medium, forming a complex that absorbs radiation at 425 nm. The photometric detection was accomplished using a homemade light-emitting-diode (LED)-based photometer designed to use a flow cell with an optical path-length of 100 mm to improve sensitivity. After selecting adequate values for the flow system variables, adherence to the Beer-Lambert-Bouguer law was observed for standard solution concentrations in the range of 0.13-1.5 µg L -1 Co(II). Other useful features including a relative standard deviation of 2.0% (n = 11) for a sample with 0.49 µg L -1 Co(II), a detection limit of 0.06 µg L -1 Co(II) (n = 20), an analytical frequency of 42 sample determinations per hour, and waste generation of 1.5 mL per determination were achieved.

  1. iSEDfit: Bayesian spectral energy distribution modeling of galaxies

    NASA Astrophysics Data System (ADS)

    Moustakas, John

    2017-08-01

    iSEDfit uses Bayesian inference to extract the physical properties of galaxies from their observed broadband photometric spectral energy distribution (SED). In its default mode, the inputs to iSEDfit are the measured photometry (fluxes and corresponding inverse variances) and a measurement of the galaxy redshift. Alternatively, iSEDfit can be used to estimate photometric redshifts from the input photometry alone. After the priors have been specified, iSEDfit calculates the marginalized posterior probability distributions for the physical parameters of interest, including the stellar mass, star-formation rate, dust content, star formation history, and stellar metallicity. iSEDfit also optionally computes K-corrections and produces multiple "quality assurance" (QA) plots at each stage of the modeling procedure to aid in the interpretation of the prior parameter choices and subsequent fitting results. The software is distributed as part of the impro IDL suite.

  2. Utilization of charge-transfer complexation for the detection of carcinogenic substances in foods: Spectroscopic characterization of ethyl carbamate with some traditional π-acceptors

    NASA Astrophysics Data System (ADS)

    Adam, Abdel Majid A.; Refat, Moamen S.; Saad, Hosam A.

    2013-04-01

    The study of toxic and carcinogenic substances in foods represents one of the most demanding areas in food safety, due to their repercussions for public health. One potentially toxic compound for humans is ethyl carbamate (EC). EC is a multi-site genotoxic carcinogen of widespread occurrence in fermented foods and alcoholic beverages. Structural and thermal stability of charge-transfer complexes formed between EC as a donor with quinol (QL), picric acid (PA), chloranilic acid (CLA), p-chloranil (p-CHL) and 1,3-dinitrobenzene (DNB) as acceptors were reported. Elemental analysis (CHN), electronic absorption spectra, photometric titration, IR, and 1H NMR spectra show that the interaction between EC and acceptors was stabilized by hydrogen bonding, via a 1:1 stoichiometry. Thermogravimetric (TG) analysis indicates that the formation of molecular CT complexes was stable, exothermic and spontaneous. Finally, the CT complexes were screened for their antibacterial and antifungal activities. The results indicated that the [(EC)(QL)] complex exhibited strong antimicrobial activities against various bacterial and fungal strains compared with standard drugs.

  3. "Why not stoichiometry" versus "Stoichiometry--why not?" Part II: GATES in context with redox systems.

    PubMed

    Michałowska-Kaczmarczyk, Anna Maria; Asuero, Agustin G; Toporek, Marcin; Michałowski, Tadeusz

    2015-01-01

    Redox equilibria and titration play an important role in chemical analysis, and the formulation of an accurate mathematical description is a challenge. This article is devoted to static and (mainly) dynamic redox systems; the dynamic systems are represented by redox titrations. An overview addresses earlier approaches to static redox systems (redox diagram plots, including Pourbaix diagrams) and to titration redox systems, thereby covering a gap in the literature. After this short review, the generalized approach to electrolytic systems (GATES) is introduced, with generalized electron balance (GEB) as its inherent part within GATES/GEB. Computer simulation, performed according to GATES/GEB, enables following the changes in potential and pH of the solution, together with chemical speciation at each step of a titration, thus providing better insight into this procedure. The undeniable advantages of GATES/GEB over earlier approaches are indicated. Formulation of GEB according to two approaches (I and II) is presented on the respective examples. A general criterion distinguishing between non-redox and redox systems is presented. It is indicated that the formulation of GEB according to Approach II does not need the knowledge of oxidation degrees of particular elements; knowledge of the composition, expressed by chemical formula of the species and its charge, is sufficient for this purpose. Approach I to GEB, known also as the "short" version of GEB, is applicable if oxidation degrees for all elements of the system are known beforehand. The roles of oxidants and reductants are not ascribed to particular components forming a system and to the species thus formed. This is the complete opposite of earlier approaches to redox titrations, based on the stoichiometric redox reaction, formulated for this purpose. GEB, perceived as a law of matter conservation, is fully compatible with other (charge and concentration) balances related to the system in question. The applicability of GATES/GEB in optimization a priori of chemical analyses made with use of redox titration is indicated. The article is illustrated with many examples of static and dynamic redox systems. The related plots are obtained from calculations made according to iterative computer programs. This way, GATES/GEB enables seeing details invisible in real experiments.

  4. Standard Free Droplet Digital Polymerase Chain Reaction as a New Tool for the Quality Control of High-Capacity Adenoviral Vectors in Small-Scale Preparations

    PubMed Central

    Boehme, Philip; Stellberger, Thorsten; Solanki, Manish; Zhang, Wenli; Schulz, Eric; Bergmann, Thorsten; Liu, Jing; Doerner, Johannes; Baiker, Armin E.

    2015-01-01

    Abstract High-capacity adenoviral vectors (HCAdVs) are promising tools for gene therapy as well as for genetic engineering. However, one limitation of the HCAdV vector system is the complex, time-consuming, and labor-intensive production process and the following quality control procedure. Since HCAdVs are deleted for all viral coding sequences, a helper virus (HV) is needed in the production process to provide the sequences for all viral proteins in trans. For the purification procedure of HCAdV, cesium chloride density gradient centrifugation is usually performed followed by buffer exchange using dialysis or comparable methods. However, performing these steps is technically difficult, potentially error-prone, and not scalable. Here, we establish a new protocol for small-scale production of HCAdV based on commercially available adenovirus purification systems and a standard method for the quality control of final HCAdV preparations. For titration of final vector preparations, we established a droplet digital polymerase chain reaction (ddPCR) that uses a standard free-end-point PCR in small droplets of defined volume. By using different probes, this method is capable of detecting and quantifying HCAdV and HV in one reaction independent of reference material, rendering this method attractive for accurately comparing viral titers between different laboratories. In summary, we demonstrate that it is possible to produce HCAdV in a small scale of sufficient quality and quantity to perform experiments in cell culture, and we established a reliable protocol for vector titration based on ddPCR. Our method significantly reduces time and required equipment to perform HCAdV production. In the future the ddPCR technology could be advantageous for titration of other viral vectors commonly used in gene therapy. PMID:25640117

  5. Neural control of ventilation prevents both over-distension and de-recruitment of experimentally injured lungs.

    PubMed

    Brander, Lukas; Moerer, Onnen; Hedenstierna, Göran; Beck, Jennifer; Takala, Jukka; Slutsky, Arthur S; Sinderby, Christer

    2017-03-01

    Endogenous pulmonary reflexes may protect the lungs during mechanical ventilation. We aimed to assess integration of continuous neurally adjusted ventilatory assist (cNAVA), delivering assist in proportion to diaphragm's electrical activity during inspiration and expiration, and Hering-Breuer inflation and deflation reflexes on lung recruitment, distension, and aeration before and after acute lung injury (ALI). In 7 anesthetised rabbits with bilateral pneumothoraces, we identified adequate cNAVA level (cNAVA AL ) at the plateau in peak ventilator pressure during titration procedures before (healthy lungs with endotracheal tube, [HL ETT ]) and after ALI (endotracheal tube [ALI ETT ] and during non-invasive ventilation [ALI NIV ]). Following titration, cNAVA AL was maintained for 5min. In 2 rabbits, procedures were repeated after vagotomy (ALI ETT+VAG ). In 3 rabbits delivery of assist was temporarily modulated to provide assist on inspiration only. Computed tomography was performed before intubation, before ALI, during cNAVA titration, and after maintenance at cNAVA AL . During ALI ETT and ALI NIV , normally aerated lung-regions doubled and poorly aerated lung-regions decreased to less than a third (p<0.05) compared to HL ETT ; no over-distension was observed. Tidal volumes were<5ml/kg throughout. Removing assist during expiration resulted in lung de-recruitment during ALI ETT , but not during ALI NIV . During ALI ETT+VAG the expiratory portion of EAdi disappeared, resulting in cyclic lung collapse and recruitment. When using cNAVA in ALI, vagally mediated reflexes regulated lung recruitment preventing both lung over-distension and atelectasis. During non-invasive cNAVA the upper airway muscles play a role in preventing atelectasis. Future studies should be performed to compare these findings with conventional lung-protective approaches. Copyright © 2016 Elsevier B.V. All rights reserved.

  6. Analyzing Serendipitous Asteroid Observations in Imaging Data using PHOTOMETRYPIPELINE

    NASA Astrophysics Data System (ADS)

    Ard, Christopher; Mommert, Michael; Trilling, David E.

    2016-10-01

    Asteroids are nearly ubiquitous in the night sky, making them present in the majority of imaging data taken every night. Serendipitous asteroid observations represent a treasure trove to Solar System researchers: accurate positional measurements of asteroids provide important constraints on their sometimes highly uncertain orbits, whereas calibrated photometric measurements can be used to establish rotational periods, intrinsic colors, or photometric phase curves.We present an add-on to the PHOTOMETRYPIPELINE (PP, github.com/mommermi/photometrypipeline, see Poster presentation 123.42) that identifies asteroids that have been observed serendipitously and extracts astrometry and calibrated photometry for these objects. PP is an open-source Python 2.7 software suite that provides image registration, aperture photometry, photometric calibration, and target identification with only minimal human interaction.Asteroids are identified based on approximate positions that are pre-calculated for a range of dates. Using interpolated coordinates, we identify potential asteroids that might be in the observed field and query their exact positions and positional uncertainties from the JPL Horizons system. The method results in robust astrometry and calibrated photometry for all asteroids in the field as a function of time. Our measurements will supplement existing photometric databases of asteroids and improve their orbits.We present first results using this procedure based on imaging data from the Vatican Advanced Technology Telescope.This work was done in the framework of NAU's REU summer program that is supported by NSF grant AST-1461200. PP was developed in the framework of the "Mission Accessible Near-Earth Object Survey" (MANOS) and is supported by NASA SSO grants NNX15AE90G and NNX14AN82G.

  7. Understanding the bias between moisture content by oven drying and water content by Karl Fischer titration at moisture equilibrium

    USDA-ARS?s Scientific Manuscript database

    Multiple causes of the difference between equilibrium moisture and water content have been found. The errors or biases were traced to the oven drying procedure to determine moisture content. The present paper explains the nature of the biases in oven drying and how it is possible to suppress one ...

  8. 3-D Topo Surface Visualization of Acid-Base Species Distributions: Corner Buttes, Corner Pits, Curving Ridge Crests, and Dilution Plains

    ERIC Educational Resources Information Center

    Smith, Garon C.; Hossain, Md Mainul

    2017-01-01

    Species TOPOS is a free software package for generating three-dimensional (3-D) topographic surfaces ("topos") for acid-base equilibrium studies. This upgrade adds 3-D species distribution topos to earlier surfaces that showed pH and buffer capacity behavior during titration and dilution procedures. It constructs topos by plotting…

  9. A SIMPLE AND RAPID METHOD FOR THE SIMULTANEOUS DETERMINATION OF CALCIUM AND MAGNESIUM FROM THE SAME SAMPLE OF BLOOD SERUM

    PubMed Central

    Kovács, G. S.; Tárnoky, K. E.

    1960-01-01

    A simple and rapid procedure has been developed for the complexometric titration of serum calcium and magnesium using “plasmocorinth B” as indicator. Both determinations can be carried out from the same 0.5 ml. sample. The method is in good agreement with the established calcium and magnesium methods. PMID:14411396

  10. Thermometric studies on the Fe(III)-EDTA chelate.

    PubMed

    Dot, K

    1978-02-01

    A DeltaH of -11.5 +/- 0.5 kJ/mole has been determined for the formation of the Fe(III)-EDTA chelate at 25.0 degrees and mu = 0.1(= [HClO(4)] + [NaClO(4)]) by a direct thermometric titration procedure. The entropy change, DeltaS, has been calculated to be 440 J.mole(-1) .deg(-1) by combining the result of the heat measurements with the free energy change obtained from the stability constant previously determined. A relationship between the DeltaS values and the standard partial molal entropies of the tervalent metal ions is discussed. In addition, conditions for the thermometric titration of Fe(III) with NA(4)EDTA at room temperature have been investigated. Iron(III) can be determined in the presence of fairly large amounts of phosphate, Cr(III), Mn(II) and Al(III).

  11. Instrument Quality Control.

    PubMed

    Jayakody, Chatura; Hull-Ryde, Emily A

    2016-01-01

    Well-defined quality control (QC) processes are used to determine whether a certain procedure or action conforms to a widely accepted standard and/or set of guidelines, and are important components of any laboratory quality assurance program (Popa-Burke et al., J Biomol Screen 14: 1017-1030, 2009). In this chapter, we describe QC procedures useful for monitoring the accuracy and precision of laboratory instrumentation, most notably automated liquid dispensers. Two techniques, gravimetric QC and photometric QC, are highlighted in this chapter. When used together, these simple techniques provide a robust process for evaluating liquid handler accuracy and precision, and critically underpin high-quality research programs.

  12. Novel microscale approaches for easy, rapid determination of protein stability in academic and commercial settings

    PubMed Central

    Alexander, Crispin G.; Wanner, Randy; Johnson, Christopher M.; Breitsprecher, Dennis; Winter, Gerhard; Duhr, Stefan; Baaske, Philipp; Ferguson, Neil

    2014-01-01

    Chemical denaturant titrations can be used to accurately determine protein stability. However, data acquisition is typically labour intensive, has low throughput and is difficult to automate. These factors, combined with high protein consumption, have limited the adoption of chemical denaturant titrations in commercial settings. Thermal denaturation assays can be automated, sometimes with very high throughput. However, thermal denaturation assays are incompatible with proteins that aggregate at high temperatures and large extrapolation of stability parameters to physiological temperatures can introduce significant uncertainties. We used capillary-based instruments to measure chemical denaturant titrations by intrinsic fluorescence and microscale thermophoresis. This allowed higher throughput, consumed several hundred-fold less protein than conventional, cuvette-based methods yet maintained the high quality of the conventional approaches. We also established efficient strategies for automated, direct determination of protein stability at a range of temperatures via chemical denaturation, which has utility for characterising stability for proteins that are difficult to purify in high yield. This approach may also have merit for proteins that irreversibly denature or aggregate in classical thermal denaturation assays. We also developed procedures for affinity ranking of protein–ligand interactions from ligand-induced changes in chemical denaturation data, and proved the principle for this by correctly ranking the affinity of previously unreported peptide–PDZ domain interactions. The increased throughput, automation and low protein consumption of protein stability determinations afforded by using capillary-based methods to measure denaturant titrations, can help to revolutionise protein research. We believe that the strategies reported are likely to find wide applications in academia, biotherapeutic formulation and drug discovery programmes. PMID:25262836

  13. Boundaries of ERTS and aircraft data within which useful water quality information can be obtained

    NASA Technical Reports Server (NTRS)

    Egan, W. G.

    1974-01-01

    Calibration procedures have been devised and applied to ERTS-1, multispectral, true color, and false color imagery. The results indicate that the ERTS and multispectral imagery are correlated with optical in situ measurements of the harbor water. Correlation is extended to true and false color imagery through in situ optical measurements of the harbor water. The best photometric accuracy is achieved with multispectral aerial imagery and the use of bulk MSS tape. The aircraft green photographic and ERTS-1 MSS-4 bands have been found most suitable for monitoring the scattered light levels under the conditions of this investigation. The application of satellite or aircraft for optical remote sensing depends upon the physical scale and frequency of sensing since both sensor systems generally have sufficient photometric sensitivity. The chemical parameters of the harbor water were found to be correlated to the optical properties for two stations investigated in detail.

  14. Kepler Ground-Based Photometry Proof-of-Concept

    NASA Technical Reports Server (NTRS)

    Brown, Timothy M.; Latham, D.; Howell, S.; Everett, M.

    2004-01-01

    We report on our efforts to evaluate the feasibility of using the 4-Shooter CCD camera on the 48-inch reflector at the Whipple Observatory to carry out a multi-band photometric survey of the Kepler target region. We also include recommendations for future work. We were assigned 36 nights with the &hooter during 2003 for this feasibility study. Most of the time during the first two dozen nights was dedicated to the development of procedures, test exposures, and a reconnaissance across the Kepler field. The final 12 nights in September and October 2003 were used for "production" observing in the middle of the Kepler field using the full complement of seven filters (SDSS u, g, r, i, z, plus our special Gred and D51 intermediate-band filters). Nine of these 12 nights were clear and photometric, and production observations were obtained at 109 pointings, corresponding to 14.6 square degrees.

  15. Video Observations Encompassing the 2002 Leonid Storm: First Results and a Revised Photometric Procedure for Video Meteor Analysis

    NASA Technical Reports Server (NTRS)

    Cooke, William J.; Suggs, Robert; Swift, Wesley; Gural, Peter S.; Brown, Peter; Ellis, Jim (Technical Monitor)

    2002-01-01

    During the 2001 Leonid storm, Marshall Space Flight Center, with the cooperation of the University of Western Ontario and the United States Air Force, deployed 6 teams of observers equipped with intensified video systems to sites located in North America, the Pacific, and Mongolia. The campaign was extremely successful, with the entire period of enhanced Leonid activity (over 16 hours) captured on video tape in a consistent manner. We present the first results from the analysis of this unique, 2 terabyte data set and discuss the problems involved in reducing large amounts of video meteor data. In particular, the question of how to determine meteor masses though photometric analysis will be re-examined, and new techniques will be proposed that eliminate some of the deficiencies suffered by the techniques currently employed in video meteor analysis.

  16. Determination of the Effect of Various Modes of Cooking on the Vitamin C Content of a Common Food, Green Pepper: An Introductory Biochemistry Experiment.

    ERIC Educational Resources Information Center

    Johnson, Eric R.

    1988-01-01

    Describes a laboratory experiment that measures the amount of ascorbic acid destroyed by food preparation methods (boiling and steaming). Points out that aqueous extracts of cooked green pepper samples can be analyzed for ascorbic acid by a relatively simple redox titration. Lists experimental procedure for four methods of preparation. (MVL)

  17. DETERMINING SERUM BICARBONATE—A Simple Syringe Titrator and Colorimeter

    PubMed Central

    Boone, Charles W.; Field, John B.

    1953-01-01

    The use of a tuberculin syringe as a burette has made possible an easy bedside technique for the determination of serum bicarbonate. By combining it with the use of a simple colorimeter, a relatively untrained person can do numerous bicarbonate determinations with a high degree of accuracy. The same technique also lends itself to other colorimetric clinical procedures such as determination of gastric acidity. PMID:13106724

  18. Determining serum bicarbonate; a simple syringe titrator and colorimeter.

    PubMed

    BOONE, C W; FIELD, J B

    1953-12-01

    The use of a tuberculin syringe as a burette has made possible an easy bedside technique for the determination of serum bicarbonate. By combining it with the use of a simple colorimeter, a relatively untrained person can do numerous bicarbonate determinations with a high degree of accuracy. The same technique also lends itself to other colorimetric clinical procedures such as determination of gastric acidity.

  19. Visualization of Buffer Capacity with 3-D "Topo" Surfaces: Buffer Ridges, Equivalence Point Canyons and Dilution Ramps

    ERIC Educational Resources Information Center

    Smith, Garon C.; Hossain, Md Mainul

    2016-01-01

    BufCap TOPOS is free software that generates 3-D topographical surfaces ("topos") for acid-base equilibrium studies. It portrays pH and buffer capacity behavior during titration and dilution procedures. Topo surfaces are created by plotting computed pH and buffer capacity values above a composition grid with volume of NaOH as the x axis…

  20. Microscale Titration in Schools Titration Competition.

    ERIC Educational Resources Information Center

    Clark, Michael J.

    1998-01-01

    Reviews the requirements of the National Titration Competition and describes how a team in a local competition used the technique. Compares microscale titration to conventional titration. Outlines the benefits of employing microscale techniques. (DDR)

  1. Complications associated with intravenous midazolam and fentanyl sedation in patients undergoing minor oral surgery

    PubMed Central

    2017-01-01

    Background Anxiety control remains an important concern in dental practice. We evaluated the incidence, nature, and sequelae of complications during and after minor oral surgeries performed under intravenous midazolam and fentanyl sedation using the titration technique. Methods The medical records of patients who had undergone minor oral surgeries under moderate intravenous midazolam and fentanyl sedation at our institution between January 1, 2015 and December 31, 2015 were retrospectively evaluated. Age, sex, body mass index, medical history, American Society of Anesthesiologists (ASA) classification, indications for sedation, amount of sedative used, surgical duration, and recovery time were evaluated for all patients. Results In total, 107 patients aged 9–84 years were included. ASA class I and class II were observed for 56.1% and 43.9% patients, respectively. Complications associated with sedation occurred in 11 (10.2%) patients. There were no serious adverse events. Oxygen saturation reached 95% during the procedure in six patients; this was successfully managed by stimulating the patients to take a deep breath. Two patients exhibited deep sedation and one exhibited paradoxical excitement. After the procedure, one patient experienced nausea without vomiting and one exhibited a prolonged recovery time. The surgical procedures were completed in all patients. Obesity was found to be significantly associated with sedation-related complications. Conclusions Our results suggest that complications associated with intravenous midazolam and fentanyl sedation using the titration technique for minor oral surgeries are mostly minor and can be successfully managed with no prolonged sequelae. PMID:29090250

  2. Optimal level of continuous positive airway pressure: auto-adjusting titration versus titration with a predictive equation.

    PubMed

    Choi, Ji Ho; Jun, Young Joon; Oh, Jeong In; Jung, Jong Yoon; Hwang, Gyu Ho; Kwon, Soon Young; Lee, Heung Man; Kim, Tae Hoon; Lee, Sang Hag; Lee, Seung Hoon

    2013-05-01

    The aims of the present study were twofold. We sought to compare two methods of titrating the level of continuous positive airway pressure (CPAP) - auto-adjusting titration and titration using a predictive equation - with full-night manual titration used as the benchmark. We also investigated the reliability of the two methods in patients with obstructive sleep apnea syndrome (OSAS). Twenty consecutive adult patients with OSAS who had successful, full-night manual and auto-adjusting CPAP titration participated in this study. The titration pressure level was calculated with a previously developed predictive equation based on body mass index and apnea-hypopnea index. The mean titration pressure levels obtained with the manual, auto-adjusting, and predictive equation methods were 9.0 +/- 3.6, 9.4 +/- 3.0, and 8.1 +/- 1.6 cm H2O,respectively. There was a significant difference in the concordance within the range of +/- 2 cm H2O (p = 0.019) between both the auto-adjusting titration and the titration using the predictive equation compared to the full-night manual titration. However, there was no significant difference in the concordance within the range of +/- 1 cm H2O (p > 0.999). When compared to full-night manual titration as the standard method, auto-adjusting titration appears to be more reliable than using a predictive equation for determining the optimal CPAP level in patients with OSAS.

  3. Determination of Carbonyl Groups in Pyrolysis Bio-oils Using Potentiometric Titration: Review and Comparison of Methods

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Black, Stuart; Ferrell, Jack R.

    Carbonyl compounds present in bio-oils are known to be responsible for bio-oil property changes upon storage and during upgrading. As such, carbonyl content has previously been used as a method of tracking bio-oil aging and condensation reactions with less variability than viscosity measurements. Given the importance of carbonyls in bio-oils, accurate analytical methods for their quantification are very important for the bio-oil community. Potentiometric titration methods based on carbonyl oximation have long been used for the determination of carbonyl content in pyrolysis bio-oils. Here in this study, we present a modification of the traditional carbonyl oximation procedures that results inmore » less reaction time, smaller sample size, higher precision, and more accurate carbonyl determinations. Some compounds such as carbohydrates are not measured by the traditional method (modified Nicolaides method), resulting in low estimations of the carbonyl content. Furthermore, we have shown that reaction completion for the traditional method can take up to 300 hours. The new method presented here (the modified Faix method) reduces the reaction time to 2 hours, uses triethanolamine (TEA) in the place of pyridine, and requires a smaller sample size for the analysis. Carbonyl contents determined using this new method are consistently higher than when using the traditional titration methods.« less

  4. Determination of Carbonyl Groups in Pyrolysis Bio-oils Using Potentiometric Titration: Review and Comparison of Methods

    DOE PAGES

    Black, Stuart; Ferrell, Jack R.

    2016-01-06

    Carbonyl compounds present in bio-oils are known to be responsible for bio-oil property changes upon storage and during upgrading. As such, carbonyl content has previously been used as a method of tracking bio-oil aging and condensation reactions with less variability than viscosity measurements. Given the importance of carbonyls in bio-oils, accurate analytical methods for their quantification are very important for the bio-oil community. Potentiometric titration methods based on carbonyl oximation have long been used for the determination of carbonyl content in pyrolysis bio-oils. Here in this study, we present a modification of the traditional carbonyl oximation procedures that results inmore » less reaction time, smaller sample size, higher precision, and more accurate carbonyl determinations. Some compounds such as carbohydrates are not measured by the traditional method (modified Nicolaides method), resulting in low estimations of the carbonyl content. Furthermore, we have shown that reaction completion for the traditional method can take up to 300 hours. The new method presented here (the modified Faix method) reduces the reaction time to 2 hours, uses triethanolamine (TEA) in the place of pyridine, and requires a smaller sample size for the analysis. Carbonyl contents determined using this new method are consistently higher than when using the traditional titration methods.« less

  5. Determination of biguanide groups in polyhexamethylene biguanide hydrochloride by titrimetric methods.

    PubMed

    Hattori, Toshiaki; Nakata, Yasuko; Kato, Ryo

    2003-11-01

    The biguanide concentration of polyhexamethylene biguanide hydrochloride (PHMB-HCl) was measured by non-aqueous titration with HClO4, argentometric titration, the Kjeldhal method, and colloidal titration. The summation value of non-aqueous titration and argentometric titration corresponded to two titrable nitrogens in five nitrogens per one unit of PHMB-HCl, and consisted with the result of the Kjeldhal method to the five nitrogens. The colloidal titration of PHMB-HCl at pH 2.05 was equal to that with the two nitrogens. The relative standard deviations of non-aqueous titration, argentometric titration, the Kjeldhal method, and colloidal titration were 0.50% for 8 runs, 0.13% for 7 runs, 3.61% for 6 runs, and 0.69% for 6 runs, respectively.

  6. The Grism Lens-amplified Survey from Space (GLASS). IV. Mass Reconstruction of the Lensing Cluster Abell 2744 from Frontier Field Imaging and GLASS Spectroscopy

    NASA Astrophysics Data System (ADS)

    Wang, X.; Hoag, A.; Huang, K.-H.; Treu, T.; Bradač, M.; Schmidt, K. B.; Brammer, G. B.; Vulcani, B.; Jones, T. A.; Ryan, R. E., Jr.; Amorín, R.; Castellano, M.; Fontana, A.; Merlin, E.; Trenti, M.

    2015-09-01

    We present a strong and weak lensing reconstruction of the massive cluster Abell 2744, the first cluster for which deep Hubble Frontier Fields (HFF) images and spectroscopy from the Grism Lens-Amplified Survey from Space (GLASS) are available. By performing a targeted search for emission lines in multiply imaged sources using the GLASS spectra, we obtain five high-confidence spectroscopic redshifts and two tentative ones. We confirm one strongly lensed system by detecting the same emission lines in all three multiple images. We also search for additional line emitters blindly and use the full GLASS spectroscopic catalog to test reliability of photometric redshifts for faint line emitters. We see a reasonable agreement between our photometric and spectroscopic redshift measurements, when including nebular emission in photometric redshift estimations. We introduce a stringent procedure to identify only secure multiple image sets based on colors, morphology, and spectroscopy. By combining 7 multiple image systems with secure spectroscopic redshifts (at 5 distinct redshift planes) with 18 multiple image systems with secure photometric redshifts, we reconstruct the gravitational potential of the cluster pixellated on an adaptive grid, using a total of 72 images. The resulting mass map is compared with a stellar mass map obtained from the deep Spitzer Frontier Fields data to study the relative distribution of stars and dark matter in the cluster. We find that the stellar to total mass ratio varies substantially across the cluster field, suggesting that stars do not trace exactly the total mass in this interacting system. The maps of convergence, shear, and magnification are made available in the standard HFF format.

  7. Photometric Detection of Extra-Solar Planets

    NASA Technical Reports Server (NTRS)

    Hatzes, Artie P.; Cochran, William D.

    2004-01-01

    This NASA Origins Program grant supported the TEMPEST Texas McDonald Photometric Extrasolar Search for Transits) program at McDonald Observatory, which searches for transits of extrasolar planets across the disks of their parent stars. The basic approach is to use a wide-field ground-based telescope (in our case the McDonald Observatory 0.76m telescope and it s Prime Focus Corrector) to search for transits of short period (1-15 day orbits) of close-in hot-Jupiter planets in orbit around a large sample of field stars. The next task is to search these data streams for possible transit events. We collected our first set of test data for this program using the 0.76 m PFC in the summer of 1998. From those data, we developed the optimal observing procedures, including tailoring the stellar density, exposure times, and filters to best-suit the instrument and project. In the summer of 1999, we obtained the first partial season of data on a dedicated field in the constellation Cygnus. These data were used to develop and refine the reduction and analysis procedures to produce high-precision photometry and search for transits in the resulting light curves. The TeMPEST project subsequently obtained three full seasons of data on six different fields using the McDonald Observatory 0.76m PFC.

  8. Thermometric titration in investigation of the formation of polyanions of molybdenum(VI), tungsten(VI), vanadium(V), and chromium (VI)-I: comparison of thermometric and potentiometric titration curves.

    PubMed

    Kiba, N; Takeuchi, T

    1973-09-01

    A new twin-cell thermometric titrator has been devised and used for thermometric titration of solutions of sodium molybdate, sodium tungstate, sodium orthovanadate, ammonium metavanadate, and potassium chromate with perchloric acid. The thermometric titration curves were compared with corresponding pH-titration curves for elucidation of the reactions occurring in the titrations. Thermometric titrimetric methods have been developed for the determination of tungsten, vanadium and chromium.

  9. Calibrating photometric redshifts of luminous red galaxies

    DOE PAGES

    Padmanabhan, Nikhil; Budavari, Tamas; Schlegel, David J.; ...

    2005-05-01

    We discuss the construction of a photometric redshift catalogue of luminous red galaxies (LRGs) from the Sloan Digital Sky Survey (SDSS), emphasizing the principal steps necessary for constructing such a catalogue: (i) photometrically selecting the sample, (ii) measuring photometric redshifts and their error distributions, and (iii) estimating the true redshift distribution. We compare two photometric redshift algorithms for these data and find that they give comparable results. Calibrating against the SDSS and SDSS–2dF (Two Degree Field) spectroscopic surveys, we find that the photometric redshift accuracy is σ~ 0.03 for redshifts less than 0.55 and worsens at higher redshift (~ 0.06more » for z < 0.7). These errors are caused by photometric scatter, as well as systematic errors in the templates, filter curves and photometric zero-points. We also parametrize the photometric redshift error distribution with a sum of Gaussians and use this model to deconvolve the errors from the measured photometric redshift distribution to estimate the true redshift distribution. We pay special attention to the stability of this deconvolution, regularizing the method with a prior on the smoothness of the true redshift distribution. The methods that we develop are applicable to general photometric redshift surveys.« less

  10. Thermometric titration of sulphate.

    PubMed

    Williams, M B; Janata, J

    1970-06-01

    Direct thermometric titration of sulphate with a solution of barium perchlorate is proposed. The stoichiometry of the titration is shown to be critically dependent on the concentration of ethanol in the titration medium. The titration is rapid and suffers from only a few interferences.

  11. Titrimetric Analysis of Han-Based Liquid Propellants

    DTIC Science & Technology

    1988-03-01

    acid-base and Karl Fischer titrimetry, procedures that quantitatively determine the three major propellant components. The method developed converts...sodium hydroxide as titrant for both HAN and TEAN. Water is determined by Karl Fischer titration using the proprietary reagent "Hydranal". Each major...water, react with one or more of the components of the Karl Fischer reagent. One of the newer Karl Fischer titrants is "Hydranal", a proprietary reagent

  12. Interplay of charge distribution and conformation in peptides: comparison of theory and experiment.

    PubMed

    Makowska, Joanna; Bagińska, Katarzyna; Kasprzykowski, F; Vila, Jorge A; Jagielska, Anna; Liwo, Adam; Chmurzyński, Lech; Scheraga, Harold A

    2005-01-01

    We assessed the correlation between charge distribution and conformation of flexible peptides by comparing the theoretically calculated potentiometric-titration curves of two model peptides, Ac-Lys5-NHMe (a model of poly-L-lysine) and Ac-Lys-Ala11-Lys-Gly2-Tyr-NH2 (P1) in water and methanol, with the experimental curves. The calculation procedure consisted of three steps: (i) global conformational search of the peptide under study using the electrostatically driven Monte Carlo (EDMC) method with the empirical conformational energy program for peptides (ECEPP)/3 force field plus the surface-hydration (SRFOPT) or the generalized Born surface area (GBSA) solvation model as well as a molecular dynamics method with the assisted model building and energy refinement (AMBER)99/GBSA force field; (ii) reevaluation of the energy in the pH range considered by using the modified Poisson-Boltzmann approach and taking into account all possible protonation microstates of each conformation, and (iii) calculation of the average degree of protonation of the peptide at a given pH value by Boltzmann averaging over conformations. For Ac-Lys5-NHMe, the computed titration curve agrees qualitatively with the experimental curve of poly-L-lysine in 95% methanol. The experimental titration curves of peptide P1 in water and methanol indicate a remarkable downshift of the first pK(a) value compared to the values for reference compounds (n-butylamine and phenol, respectively), suggesting the presence of a hydrogen bond between the tyrosine hydroxyl oxygen and the H(epsilon) proton of a protonated lysine side chain. The theoretical titration curves agree well with the experimental curves, if conformations with such hydrogen bonds constitute a significant part of the ensemble; otherwise, the theory predicts too small a downward pH shift. Copyright 2005 Wiley Periodicals, Inc

  13. Production of first generation adenoviral vectors for preclinical protocols: amplification, purification and functional titration.

    PubMed

    Armendáriz-Borunda, Juan; Bastidas-Ramírez, Blanca Estela; Sandoval-Rodríguez, Ana; González-Cuevas, Jaime; Gómez-Meda, Belinda; García-Bañuelos, Jesús

    2011-11-01

    Gene therapy represents a promising approach in the treatment of several diseases. Currently, the ideal vector has yet to be designed; though, adenoviral vectors (Ad-v) have provided the most utilized tool for gene transfer due principally to their simple production, among other specific characteristics. Ad-v viability represents a critical variable that may be affected by storage or shipping conditions and therefore it is advisable to be assessed previously to protocol performance. The present work is unique in this matter, as the complete detailed process to obtain Ad-v of preclinical grade is explained. Amplification in permissive HEK-293 cells, purification in CsCl gradients in a period of 10 h, spectrophotometric titration of viral particles (VP) and titration of infectious units (IU), yielding batches of AdβGal, AdGFP, AdHuPA and AdMMP8, of approximately 10¹³-10¹⁴ VP and 10¹²-10¹³ IU were carried out. In vivo functionality of therapeutic AdHuPA and AdMMP8 was evidenced in rats presenting CCl₄-induced fibrosis, as more than 60% of fibrosis was eliminated in livers after systemic delivery through iliac vein in comparison with irrelevant AdβGal. Time required to accomplish the whole Ad-v production steps, including IU titration was 20 to 30 days. We conclude that production of Ad-v following standard operating procedures assuring vector functionality and the possibility to effectively evaluate experimental gene therapy results, leaving aside the use of high-cost commercial kits or sophisticated instrumentation, can be performed in a conventional laboratory of cell culture. Copyright © 2011 The Society for Biotechnology, Japan. Published by Elsevier B.V. All rights reserved.

  14. Robust photometric invariant features from the color tensor.

    PubMed

    van de Weijer, Joost; Gevers, Theo; Smeulders, Arnold W M

    2006-01-01

    Luminance-based features are widely used as low-level input for computer vision applications, even when color data is available. The extension of feature detection to the color domain prevents information loss due to isoluminance and allows us to exploit the photometric information. To fully exploit the extra information in the color data, the vector nature of color data has to be taken into account and a sound framework is needed to combine feature and photometric invariance theory. In this paper, we focus on the structure tensor, or color tensor, which adequately handles the vector nature of color images. Further, we combine the features based on the color tensor with photometric invariant derivatives to arrive at photometric invariant features. We circumvent the drawback of unstable photometric invariants by deriving an uncertainty measure to accompany the photometric invariant derivatives. The uncertainty is incorporated in the color tensor, hereby allowing the computation of robust photometric invariant features. The combination of the photometric invariance theory and tensor-based features allows for detection of a variety of features such as photometric invariant edges, corners, optical flow, and curvature. The proposed features are tested for noise characteristics and robustness to photometric changes. Experiments show that the proposed features are robust to scene incidental events and that the proposed uncertainty measure improves the applicability of full invariants.

  15. A novel approach for high precision rapid potentiometric titrations: application to hydrazine assay.

    PubMed

    Sahoo, P; Malathi, N; Ananthanarayanan, R; Praveen, K; Murali, N

    2011-11-01

    We propose a high precision rapid personal computer (PC) based potentiometric titration technique using a specially designed mini-cell to carry out redox titrations for assay of chemicals in quality control laboratories attached to industrial, R&D, and nuclear establishments. Using this technique a few microlitre of sample (50-100 μl) in a total volume of ~2 ml solution can be titrated and the waste generated after titration is extremely low comparing to that obtained from the conventional titration technique. The entire titration including online data acquisition followed by immediate offline analysis of data to get information about concentration of unknown sample is completed within a couple of minutes (about 2 min). This facility has been created using a new class of sensors, viz., pulsating sensors developed in-house. The basic concept in designing such instrument and the salient features of the titration device are presented in this paper. The performance of the titration facility was examined by conducting some of the high resolution redox titrations using dilute solutions--hydrazine against KIO(3) in HCl medium, Fe(II) against Ce(IV) and uranium using Davies-Gray method. The precision of titrations using this innovative approach lies between 0.048% and 1.0% relative standard deviation in different redox titrations. With the evolution of this rapid PC based titrator it was possible to develop a simple but high precision potentiometric titration technique for quick determination of hydrazine in nuclear fuel dissolver solution in the context of reprocessing of spent nuclear fuel in fast breeder reactors. © 2011 American Institute of Physics

  16. A novel approach for high precision rapid potentiometric titrations: Application to hydrazine assay

    NASA Astrophysics Data System (ADS)

    Sahoo, P.; Malathi, N.; Ananthanarayanan, R.; Praveen, K.; Murali, N.

    2011-11-01

    We propose a high precision rapid personal computer (PC) based potentiometric titration technique using a specially designed mini-cell to carry out redox titrations for assay of chemicals in quality control laboratories attached to industrial, R&D, and nuclear establishments. Using this technique a few microlitre of sample (50-100 μl) in a total volume of ˜2 ml solution can be titrated and the waste generated after titration is extremely low comparing to that obtained from the conventional titration technique. The entire titration including online data acquisition followed by immediate offline analysis of data to get information about concentration of unknown sample is completed within a couple of minutes (about 2 min). This facility has been created using a new class of sensors, viz., pulsating sensors developed in-house. The basic concept in designing such instrument and the salient features of the titration device are presented in this paper. The performance of the titration facility was examined by conducting some of the high resolution redox titrations using dilute solutions--hydrazine against KIO3 in HCl medium, Fe(II) against Ce(IV) and uranium using Davies-Gray method. The precision of titrations using this innovative approach lies between 0.048% and 1.0% relative standard deviation in different redox titrations. With the evolution of this rapid PC based titrator it was possible to develop a simple but high precision potentiometric titration technique for quick determination of hydrazine in nuclear fuel dissolver solution in the context of reprocessing of spent nuclear fuel in fast breeder reactors.

  17. Multi-complexity measures of heart rate variability and the effect of vasopressor titration: a prospective cohort study of patients with septic shock.

    PubMed

    Brown, Samuel M; Sorensen, Jeffrey; Lanspa, Michael J; Rondina, Matthew T; Grissom, Colin K; Shahul, Sajid; Mathews, V J

    2016-10-10

    Septic shock is a common and often devastating syndrome marked by severe cardiovascular dysfunction commonly managed with vasopressors. Whether markers of heart rate complexity before vasopressor up-titration could be used to predict success of the up-titration is not known. We studied patients with septic shock requiring vasopressor, newly admitted to the intensive care unit. We measured the complexity of heart rate variability (using the ratio of fractal exponents from detrended fluctuation analysis) in the 5 min before all vasopressor up-titrations in the first 24 h of an intensive care unit (ICU) admission. A successful up-titration was defined as one that did not require further up-titration (or decrease in mean arterial pressure) for 60 min. We studied 95 patients with septic shock, with a median APACHE II of 27 (IQR: 20-37). The median number of up-titrations, normalized to 24 h, was 12.2 (IQR: 8-17) with a maximum of 49. Of the up-titrations, the median proportion of successful interventions was 0.28 (IQR: 0.12-0.42). The median of mean arterial pressure (MAP) at the time of a vasopressor up-titration was 66 mmHg; the average infusion rate of norepinephrine at the time of an up-titration was 0.11 mcg/kg/min. The ratio of fractal exponents was not associated with successful up-titration on univariate or multivariate regression. On exploratory secondary analyses, however, the long-term fractal exponent was associated (p = 0.003) with success of up-titration. Independent of heart rate variability, MAP was associated (p < 0.001) with success of vasopressor up-titration, while neither Sequential Organ Failure Assessment (SOFA) nor Acute Physiology and Chronic Health Evaluation II (APACHE II) score was associated with vasopressor titration. Only a third of vasopressor up-titrations were successful among patients with septic shock. MAP and the long-term fractal exponent were associated with success of up-titration. These two, complementary variables may be important to the development of rational vasopressor titration protocols.

  18. Dark Energy Survey Year 1 Results: redshift distributions of the weak-lensing source galaxies

    NASA Astrophysics Data System (ADS)

    Hoyle, B.; Gruen, D.; Bernstein, G. M.; Rau, M. M.; De Vicente, J.; Hartley, W. G.; Gaztanaga, E.; DeRose, J.; Troxel, M. A.; Davis, C.; Alarcon, A.; MacCrann, N.; Prat, J.; Sánchez, C.; Sheldon, E.; Wechsler, R. H.; Asorey, J.; Becker, M. R.; Bonnett, C.; Carnero Rosell, A.; Carollo, D.; Carrasco Kind, M.; Castander, F. J.; Cawthon, R.; Chang, C.; Childress, M.; Davis, T. M.; Drlica-Wagner, A.; Gatti, M.; Glazebrook, K.; Gschwend, J.; Hinton, S. R.; Hoormann, J. K.; Kim, A. G.; King, A.; Kuehn, K.; Lewis, G.; Lidman, C.; Lin, H.; Macaulay, E.; Maia, M. A. G.; Martini, P.; Mudd, D.; Möller, A.; Nichol, R. C.; Ogando, R. L. C.; Rollins, R. P.; Roodman, A.; Ross, A. J.; Rozo, E.; Rykoff, E. S.; Samuroff, S.; Sevilla-Noarbe, I.; Sharp, R.; Sommer, N. E.; Tucker, B. E.; Uddin, S. A.; Varga, T. N.; Vielzeuf, P.; Yuan, F.; Zhang, B.; Abbott, T. M. C.; Abdalla, F. B.; Allam, S.; Annis, J.; Bechtol, K.; Benoit-Lévy, A.; Bertin, E.; Brooks, D.; Buckley-Geer, E.; Burke, D. L.; Busha, M. T.; Capozzi, D.; Carretero, J.; Crocce, M.; D'Andrea, C. B.; da Costa, L. N.; DePoy, D. L.; Desai, S.; Diehl, H. T.; Doel, P.; Eifler, T. F.; Estrada, J.; Evrard, A. E.; Fernandez, E.; Flaugher, B.; Fosalba, P.; Frieman, J.; García-Bellido, J.; Gerdes, D. W.; Giannantonio, T.; Goldstein, D. A.; Gruendl, R. A.; Gutierrez, G.; Honscheid, K.; James, D. J.; Jarvis, M.; Jeltema, T.; Johnson, M. W. G.; Johnson, M. D.; Kirk, D.; Krause, E.; Kuhlmann, S.; Kuropatkin, N.; Lahav, O.; Li, T. S.; Lima, M.; March, M.; Marshall, J. L.; Melchior, P.; Menanteau, F.; Miquel, R.; Nord, B.; O'Neill, C. R.; Plazas, A. A.; Romer, A. K.; Sako, M.; Sanchez, E.; Santiago, B.; Scarpine, V.; Schindler, R.; Schubnell, M.; Smith, M.; Smith, R. C.; Soares-Santos, M.; Sobreira, F.; Suchyta, E.; Swanson, M. E. C.; Tarle, G.; Thomas, D.; Tucker, D. L.; Vikram, V.; Walker, A. R.; Weller, J.; Wester, W.; Wolf, R. C.; Yanny, B.; Zuntz, J.

    2018-07-01

    We describe the derivation and validation of redshift distribution estimates and their uncertainties for the populations of galaxies used as weak-lensing sources in the Dark Energy Survey (DES) Year 1 cosmological analyses. The Bayesian Photometric Redshift (BPZ) code is used to assign galaxies to four redshift bins between z ≈ 0.2 and ≈1.3, and to produce initial estimates of the lensing-weighted redshift distributions n^i_PZ(z)∝ dn^i/dz for members of bin i. Accurate determination of cosmological parameters depends critically on knowledge of ni, but is insensitive to bin assignments or redshift errors for individual galaxies. The cosmological analyses allow for shifts n^i(z)=n^i_PZ(z-Δ z^i) to correct the mean redshift of ni(z) for biases in n^i_PZ. The Δzi are constrained by comparison of independently estimated 30-band photometric redshifts of galaxies in the Cosmic Evolution Survey (COSMOS) field to BPZ estimates made from the DES griz fluxes, for a sample matched in fluxes, pre-seeing size, and lensing weight to the DES weak-lensing sources. In companion papers, the Δzi of the three lowest redshift bins are further constrained by the angular clustering of the source galaxies around red galaxies with secure photometric redshifts at 0.15 < z < 0.9. This paper details the BPZ and COSMOS procedures, and demonstrates that the cosmological inference is insensitive to details of the ni(z) beyond the choice of Δzi. The clustering and COSMOS validation methods produce consistent estimates of Δzi in the bins where both can be applied, with combined uncertainties of σ_{Δ z^i}=0.015, 0.013, 0.011, and 0.022 in the four bins. Repeating the photo-z procedure instead using the Directional Neighbourhood Fitting algorithm, or using the ni(z) estimated from the matched sample in COSMOS, yields no discernible difference in cosmological inferences.

  19. Shedding light on the photostability of two intermolecular charge-transfer complexes between highly fluorescent bis-1,8-naphthalimide dyes and some π-acceptors: A spectroscopic study in solution and solid states

    NASA Astrophysics Data System (ADS)

    Refat, Moamen S.; Ismail, Lamia A.; Adam, Abdel Majid A.

    2015-01-01

    Given the great importance of the various uses of 1,8-naphthalimides in the trends of biology, medicine and industry, the current study focused on extending the scope of these dyes by introducing some of their charge-transfer (CT) complexes. For this purpose, two highly fluorescent bis-1,8-naphthalimide dyes and their complexes with some π-acceptors have been synthesized and characterized spectroscopically. The π-acceptors include picric acid (PA), chloranilic acid (CLA), tetracyanoquinodimethane (TCNQ) and dichlorodicyanobenzoquinone (DDQ). The molecular structure, spectroscopic and fluorescence properties as well as the binding modes were deduced from IR, UV-vis and 1H NMR spectral studies. The binding ratio of complexation was determined to be 1:1 according to the elemental analyses and photometric titrations. It has been found that the order of acceptance ability for the different acceptors is TCNQ > DDQ > CLA > PA. The photostability of 1,8-naphthalimide dye as a donor and its charge-transfer complex doped in polymethyl methacrylate/PMMA were exposed to UV-Vis radiation and the change in the absorption spectra was achieved at different times during irradiation period.

  20. Preparation, spectroscopic and antibacterial studies on charge-transfer complexes of 2-hydroxypyridine with picric acid and 7,7‧,8,8‧-tetracyano-p-quinodimethane

    NASA Astrophysics Data System (ADS)

    Gaballa, Akmal S.; Amin, Alaa S.

    2015-06-01

    The reactions of electron acceptors such as picric acid (HPA) and 7,7‧,8,8‧-tetracyano-p-quinodimethane (TCNQ) with 2-hydroxypyridine (HPyO) have been investigated in EtOH at room temperature. Based on elemental analysis and IR spectra of the solid CT-complexes along with the photometric titration curves for the reactions, the data obtained indicate the formation of 1:1 charge transfer complexes [(H2PyO)(PA)] and [(PyO)(HTCNQ)], respectively. The infrared and 1H NMR spectroscopic data indicate a charge transfer interaction associated with a proton migration from the acceptor to the donor followed by intramolecular hydrogen bonding in [(H2PyO)(PA)] complex. Another charge transfer interaction was observed in [(PyO)(HTCNQ)] complex. The formation constants (KCT) for the CT-complexes are shown to be strongly dependent on the type and structure of the electron acceptors. Factors affecting the CT-processes and the kinetics of thermal decomposition of the complexes have been studied. The CT complexes were screened for their antibacterial activities against selected bacterial strains.

  1. Intermolecular hydrogen bond complexes by in situ charge transfer complexation of o-tolidine with picric and chloranilic acids

    NASA Astrophysics Data System (ADS)

    Refat, Moamen S.; Saad, Hosam A.; Adam, Abdel Majid A.

    2011-08-01

    A two new charge transfer complexes formed from the interactions between o-tolidine (o-TOL) and picric (PA) or chloranilic (CA) acids, with the compositions, [(o-TOL)(PA) 2] and [(o-TOL)(CA) 2] have been prepared. The 13C NMR, 1H NMR, 1H-Cosy, and IR show that the charge-transfer chelation occurs via the formation of chain structures O-H⋯N intermolecular hydrogen bond between 2NH 2 groups of o-TOL molecule and OH group in each PA or CA units. Photometric titration measurements concerning the two reactions in methanol were performed and the measurements show that the donor-acceptor molar ratio was found to be 1:2 using the modified Benesi-Hildebrand equation. The spectroscopic data were discussed in terms of formation constant, molar extinction coefficient, oscillator strength, dipole moment, standard free energy, and ionization potential. Thermal behavior of both charge transfer complexes showed that the complexes were more stable than their parents. The thermodynamic parameters were estimated from the differential thermogravimetric curves. The results indicated that the formation of molecular charge transfer complexes is spontaneous and endothermic.

  2. Preparation, spectroscopic and antibacterial studies on charge-transfer complexes of 2-hydroxypyridine with picric acid and 7,7',8,8'-tetracyano-p-quinodimethane.

    PubMed

    Gaballa, Akmal S; Amin, Alaa S

    2015-06-15

    The reactions of electron acceptors such as picric acid (HPA) and 7,7',8,8'-tetracyano-p-quinodimethane (TCNQ) with 2-hydroxypyridine (HPyO) have been investigated in EtOH at room temperature. Based on elemental analysis and IR spectra of the solid CT-complexes along with the photometric titration curves for the reactions, the data obtained indicate the formation of 1:1 charge transfer complexes [(H2PyO)(PA)] and [(PyO)(HTCNQ)], respectively. The infrared and (1)H NMR spectroscopic data indicate a charge transfer interaction associated with a proton migration from the acceptor to the donor followed by intramolecular hydrogen bonding in [(H2PyO)(PA)] complex. Another charge transfer interaction was observed in [(PyO)(HTCNQ)] complex. The formation constants (KCT) for the CT-complexes are shown to be strongly dependent on the type and structure of the electron acceptors. Factors affecting the CT-processes and the kinetics of thermal decomposition of the complexes have been studied. The CT complexes were screened for their antibacterial activities against selected bacterial strains. Copyright © 2015 Elsevier B.V. All rights reserved.

  3. Intermolecular hydrogen bond complexes by in situ charge transfer complexation of o-tolidine with picric and chloranilic acids.

    PubMed

    Refat, Moamen S; Saad, Hosam A; Adam, Abdel Majid A

    2011-08-01

    A two new charge transfer complexes formed from the interactions between o-tolidine (o-TOL) and picric (PA) or chloranilic (CA) acids, with the compositions, [(o-TOL)(PA)(2)] and [(o-TOL)(CA)(2)] have been prepared. The (13)C NMR, (1)H NMR, (1)H-Cosy, and IR show that the charge-transfer chelation occurs via the formation of chain structures O-H⋯N intermolecular hydrogen bond between 2NH(2) groups of o-TOL molecule and OH group in each PA or CA units. Photometric titration measurements concerning the two reactions in methanol were performed and the measurements show that the donor-acceptor molar ratio was found to be 1:2 using the modified Benesi-Hildebrand equation. The spectroscopic data were discussed in terms of formation constant, molar extinction coefficient, oscillator strength, dipole moment, standard free energy, and ionization potential. Thermal behavior of both charge transfer complexes showed that the complexes were more stable than their parents. The thermodynamic parameters were estimated from the differential thermogravimetric curves. The results indicated that the formation of molecular charge transfer complexes is spontaneous and endothermic. Copyright © 2011 Elsevier B.V. All rights reserved.

  4. Astrometric Calibration and Performance of the Dark Energy Camera

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bernstein, G. M.; Armstrong, R.; Plazas, A. A.

    2017-05-30

    We characterize the variation in photometric response of the Dark Energy Camera (DECam) across its 520~Mpix science array during 4 years of operation. These variations are measured using high signal-to-noise aperture photometry ofmore » $>10^7$ stellar images in thousands of exposures of a few selected fields, with the telescope dithered to move the sources around the array. A calibration procedure based on these results brings the RMS variation in aperture magnitudes of bright stars on cloudless nights down to 2--3 mmag, with <1 mmag of correlated photometric errors for stars separated by $$\\ge20$$". On cloudless nights, any departures of the exposure zeropoints from a secant airmass law exceeding >1 mmag are plausibly attributable to spatial/temporal variations in aperture corrections. These variations can be inferred and corrected by measuring the fraction of stellar light in an annulus between 6" and 8" diameter. Key elements of this calibration include: correction of amplifier nonlinearities; distinguishing pixel-area variations and stray light from quantum-efficiency variations in the flat fields; field-dependent color corrections; and the use of an aperture-correction proxy. The DECam response pattern across the 2-degree field drifts over months by up to $$\\pm7$$ mmag, in a nearly-wavelength-independent low-order pattern. We find no fundamental barriers to pushing global photometric calibrations toward mmag accuracy.« less

  5. A Photometric Observing Program at the VATT: Setting Up a Calibration Field

    NASA Astrophysics Data System (ADS)

    Davis Philip, A. G.; Boyle, R. P.; Janusz, R.

    2009-05-01

    Philip and Boyle have been making Strömgren and then Strömvil photometric observations of open and globular clusters at the Vatican Advanced Technology Telescope located on Mt. Graham in Arizona. Our aim is to obtain CCD photometric indices good to 0.01 magnitude. Indices of this quality can later be analyzed to yield estimates of temperature, luminosity and metallicity. But we have found that the CCD chip does not yield photometry of this quality without further corrections. Our most observed cluster is the open cluster, M 67. This cluster is also very well observed in the literature. We took the best published values and created a set of "standard" stars for our field. Taking our CCD results we could calculate deltas, as a function of position on the chip, which we then applied to all the CCD frames that we obtained. With this procedure we were able to obtain the precision of 0.01 magnitudes in all the fields that we observed. When we started we were able to use the "A" two-inch square Strömgren four-color set from KPNO. Later the Vatican Observatory bought a set of 3.48 inch square Strömgren filters, The Vatican Observatory had a set of circular Vilnius filters There was also an X filter. These eight filters made our Strömvil set.

  6. Determining a Solubility Product Constant by Potentiometric Titration to Increase Students' Conceptual Understanding of Potentiometry and Titrations

    ERIC Educational Resources Information Center

    Grabowski, Lauren E.; Goode, Scott R.

    2017-01-01

    Potentiometric titrations are widely taught in first-year undergraduate courses to connect electrochemistry, stoichiometry, and equilibria and to reinforce acid-base titrations. Students perform a potentiometric titration that is then analyzed to determine analyte concentrations and the solubility product constant of the solid species.

  7. Theoretical problems associated with the use of acetic anhydride as a co-solvent for the non-aqueous titration of hydrohalides of organic bases and quaternary ammonium salts.

    PubMed

    Völgyi, Gergely; Béni, Szabolcs; Takács-Novák, Krisztina; Görög, Sándor

    2010-01-05

    A potentiometric titration study of organic base hydrohalides and quaternary ammonium salts using perchloric acid as the titrant and a mixture of acetic anhydride and acetic acid as the solvent was carried out and the titration mixture was analysed by NMR in order to clarify the chemistry of the reactions involved. It was found that in contrast to the general belief the formation of acetyl halides and titratable free acetate ion does not take place prior to the titration but NMR spectra proved the formation of acetyl halides in the course of the titration. This observation and the fact that the shape of the titration curves depends on the nature of the hydrohaloic acid bound to the base or of the anion in the quaternary ammonium salts led to the conclusion that the titrating agent is acetyl perchlorate formed in situ during the titration. Equations of the reactions involved in the titration process are shown in the paper.

  8. The wavelength dependence and an interpretation of the photometric parameters of Mars

    NASA Technical Reports Server (NTRS)

    Weaver, W. R.; Meador, W. E.

    1976-01-01

    The photometric function developed by Meador and Weaver has been used with photometric data from the bright desert areas of Mars to determine the wavelength dependence of the three photometric parameters of that function and to provide some predictions about the physical properties of the surface. Knowledge of the parameters permits the brightness of these areas of Mars to be determined for scattering geometry over the wavelength range of 0.45 to 0.70 micrometer. The changes in the photometric parameters with wavelength are shown to be consistent with qualitative theoretical predictions, and the predictions of surface properties are shown to be consistent with conditions that might exist in these regions of Mars. The photometric function is shown to have good potential as a diagnostic tool for the determination of surface properties, and the consistency of the behavior of the photometric parameters is shown to be good support for the validity of the photometric function.

  9. Droplet-counting Microtitration System for Precise On-site Analysis.

    PubMed

    Kawakubo, Susumu; Omori, Taichi; Suzuki, Yasutada; Ueta, Ikuo

    2018-01-01

    A new microtitration system based on the counting of titrant droplets has been developed for precise on-site analysis. The dropping rate was controlled by inserting a capillary tube as a flow resistance in a laboratory-made micropipette. The error of titration was 3% in a simulated titration with 20 droplets. The pre-addition of a titrant was proposed for precise titration within an error of 0.5%. The analytical performances were evaluated for chelate titration, redox titration and acid-base titration.

  10. Supernova Cosmology Inference with Probabilistic Photometric Redshifts (SCIPPR)

    NASA Astrophysics Data System (ADS)

    Peters, Christina; Malz, Alex; Hlozek, Renée

    2018-01-01

    The Bayesian Estimation Applied to Multiple Species (BEAMS) framework employs probabilistic supernova type classifications to do photometric SN cosmology. This work extends BEAMS to replace high-confidence spectroscopic redshifts with photometric redshift probability density functions, a capability that will be essential in the era the Large Synoptic Survey Telescope and other next-generation photometric surveys where it will not be possible to perform spectroscopic follow up on every SN. We present the Supernova Cosmology Inference with Probabilistic Photometric Redshifts (SCIPPR) Bayesian hierarchical model for constraining the cosmological parameters from photometric lightcurves and host galaxy photometry, which includes selection effects and is extensible to uncertainty in the redshift-dependent supernova type proportions. We create a pair of realistic mock catalogs of joint posteriors over supernova type, redshift, and distance modulus informed by photometric supernova lightcurves and over redshift from simulated host galaxy photometry. We perform inference under our model to obtain a joint posterior probability distribution over the cosmological parameters and compare our results with other methods, namely: a spectroscopic subset, a subset of high probability photometrically classified supernovae, and reducing the photometric redshift probability to a single measurement and error bar.

  11. Intravenous infusion of prostaglandin E2 for management of premature rupture of membranes.

    PubMed

    Thiery, M; Parewijck, W; Martens, G

    1982-01-01

    In term with premature rupture of the membranes (PROM) and an unripe cervix who have no contraindications for prostaglandin (PG) administration and vaginal delivery, intravenous (I.V.) infusion of titrated PGE2 is highly effective. In healthy gravidas with dito fetus this treatment appeared perinatally safe and was well tolerated by the mother. To enhance its safety margin and procedure must be conducted under toco-cardiographic control.

  12. [Comparison of different continuous positive airway pressure titration methods for obstructive sleep apnea hypopnea syndrome].

    PubMed

    Li, Jingjing; Ye, Jingying; Zhang, Peng; Kang, Dan; Cao, Xin; Zhang, Yuhuan; Ding, Xiu; Zheng, Li; Li, Hongguang; Bian, Qiuli

    2014-10-01

    To explore whether there were differences between the results of automatic titration and the results of manual titration for positive airway pressure treatment in patients with obstructive sleep apnea hypopnea syndrome (OSAHS) and its influencing factors, the results might provide a theoretical basis for the rational use of two pressure titration methods. Sixty one patients with OSAHS were included in this study. All patients underwent a manual titration and an automatic titration within one week. The clinical informations, polysomnography data, and the results of both two titration of all patients were obtained for analysis. The overall apnea/hypopnea index was (63.1 ± 17.7)/h, with a range of 14.9/h to 110.4/h. The treatment pressure of manual titration was (8.4 ± 2.1) cmH(2)O, which was significantly lower than the treatment pressure of automatic titration, (11.5 ± 2.7) cmH(2)O (t = -9.797, P < 0.001). After using a ΔP of 3 cmH(2)O for the cutoff value (ΔP was defined as the difference of automatic titration and manual titration), it was found that the pressure of automatic titration was significantly higher in patients with a ΔP > 3 cmH(2)O than in patients with a ΔP ≤ 3 cmH(2)O, which was (13.3 ± 2.3) cmH(2)O vs (10.0 ± 2.0) cmH(2)O (t = -6.159, P < 0.001). However, there were no differences for the pressure of manual titration between these two groups, which was (8.6 ± 2.4) cmH(2)O vs (8.3 ± 2.0)cmH(2)O (P > 0.05). There was no significant difference in age, body mass index, neck circumference, abdomen circumference, apnea hypopnea index, and arterial oxygen saturation between these two groups. The treatment pressure of automatic titration is usually higher than that of manual titration. For patients with a high treatment pressure which is derived from automatic titration, a suggestion about manual titration could be given to decrease the potential treatment pressure of continuous positive airway pressure, which may be helpful in improving the comfortableness and the compliance of this treatment.

  13. VizieR Online Data Catalog: WINGS: Deep optical phot. of 77 nearby clusters (Varela+, 2009)

    NASA Astrophysics Data System (ADS)

    Varela, J.; D'Onofrio, M.; Marmo, C.; Fasano, G.; Bettoni, D.; Cava, A.; Couch, J. W.; Dressler, A.; Kjaergaard, P.; Moles, M.; Pignatelli, E.; Poggianti, M. B.; Valentinuzzi, T.

    2009-05-01

    This is the second paper of a series devoted to the WIde Field Nearby Galaxy-cluster Survey (WINGS). WINGS is a long term project which is gathering wide-field, multi-band imaging and spectroscopy of galaxies in a complete sample of 77 X-ray selected, nearby clusters (0.04200deg). The main goal of this project is to establish a local reference for evolutionary studies of galaxies and galaxy clusters. This paper presents the optical (B,V) photometric catalogs of the WINGS sample and describes the procedures followed to construct them. We have paid special care to correctly treat the large extended galaxies (which includes the brightest cluster galaxies) and the reduction of the influence of the bright halos of very bright stars. We have constructed photometric catalogs based on wide-field images in B and V bands using SExtractor. Photometry has been performed on images in which large galaxies and halos of bright stars were removed after modeling them with elliptical isophotes. We publish deep optical photometric catalogs (90% complete at V21.7, which translates to ~ MV* + 6 at mean redshift), giving positions, geometrical parameters, and several total and aperture magnitudes for all the objects detected. For each field we have produced three catalogs containing galaxies, stars and objects of "unknown" classification (~16%). From simulations we found that the uncertainty of our photometry is quite dependent of the light profile of the objects with stars having the most robust photometry and de Vaucouleurs profiles showing higher uncertainties and also an additional bias of ~-0.2m. The star/galaxy classification of the bright objects (V<20) was checked visually making negligible the fraction of misclassified objects. For fainter objects, we found that simulations do not provide reliable estimates of the possible misclassification and therefore we have compared our data with that from deep counts of galaxies and star counts from models of our Galaxy. Both sets turned out to be consistent with our data within ~5% (in the ratio galaxies/total) up to V~24. Finally, we remark that the application of our special procedure to remove large halos improves the photometry of the large galaxies in our sample with respect to the use of blind automatic procedures and increases (~16%) the detection rate of objects projected onto them. (4 data files).

  14. Limitations of pH-potentiometric titration for the determination of the degree of deacetylation of chitosan.

    PubMed

    Balázs, Nándor; Sipos, Pál

    2007-01-15

    The degree of deacetylation (DDA) of chitosan determines the biopolymer's physico-chemical properties and technological applications. pH-Potentiometric titration seems to offer a simple and convenient means of determining DDA. However, to obtain accurate pH-potentiometric DDA values, several factors have to be taken into consideration. We found that the moisture content of the air-dry chitosan samples can be as high as 15%, and a reasonable fraction of this humidity cannot be removed by ordinary drying. Corrections have to be made for the ash content, as in some samples it can be as high as 1% by weight. The method of equivalence point determination was also found to cause systematic variations in the results and in some samples extra acid as high as 1 mol% of the free amino content was also identified. To compensate for the latter effect, the second equivalence point of the titration has to be determined separately and the analytical concentration of the acid be corrected for it. All the corrections listed here are necessary to obtain DDA values that are in reasonable agreement with those obtained from (1)H NMR and IR spectroscopic measurements. The need for these corrections severely limits the usefulness of pH-metry for determining accurate DDA values and thus potentiometry is hardly able to compete with other standard spectroscopic procedures, that is, (1)H NMR spectroscopy.

  15. Modified spectrophotometer for multi-dimensional circular dichroism/fluorescence data acquisition in titration experiments: application to the pH and guanidine-HCI induced unfolding of apomyoglobin.

    PubMed

    Ramsay, G; Ionescu, R; Eftink, M R

    1995-08-01

    In a previous paper (Ramsay and Eftink, Biophys. J. 66:516-523) we reported the development of a modified spectrophotometer that can make nearly simultaneous circular dichroism (CD) and fluorescence measurements. This arrangement allows multiple data sets to be collected during a single experiment, resulting in a saving of time and material, and improved correlation between the different types of measurements. The usefulness of the instrument was shown by thermal melting experiments on several different protein systems. This CD/fluorometer spectrophotometer has been further modified by interfacing with a syringe pump and a pH meter. This arrangement allows ligand, pH, and chemical denaturation titration experiments to be performed while monitoring changes in the sample's CD, absorbance, fluorescence, and light scattering properties. Our data acquisition program also has an ability to check whether the signals have approached equilibrium before the data is recorded. For performing pH titrations we have developed a procedure which uses the signal from a pH meter in a feedback circuit in order to collect data at evenly spaced pH intervals. We demonstrate the use of this instrument with studies of the unfolding of sperm whale apomyoglobin, as induced by acid pH and by the addition of guanidine-HCI.

  16. Modified spectrophotometer for multi-dimensional circular dichroism/fluorescence data acquisition in titration experiments: application to the pH and guanidine-HCI induced unfolding of apomyoglobin.

    PubMed Central

    Ramsay, G; Ionescu, R; Eftink, M R

    1995-01-01

    In a previous paper (Ramsay and Eftink, Biophys. J. 66:516-523) we reported the development of a modified spectrophotometer that can make nearly simultaneous circular dichroism (CD) and fluorescence measurements. This arrangement allows multiple data sets to be collected during a single experiment, resulting in a saving of time and material, and improved correlation between the different types of measurements. The usefulness of the instrument was shown by thermal melting experiments on several different protein systems. This CD/fluorometer spectrophotometer has been further modified by interfacing with a syringe pump and a pH meter. This arrangement allows ligand, pH, and chemical denaturation titration experiments to be performed while monitoring changes in the sample's CD, absorbance, fluorescence, and light scattering properties. Our data acquisition program also has an ability to check whether the signals have approached equilibrium before the data is recorded. For performing pH titrations we have developed a procedure which uses the signal from a pH meter in a feedback circuit in order to collect data at evenly spaced pH intervals. We demonstrate the use of this instrument with studies of the unfolding of sperm whale apomyoglobin, as induced by acid pH and by the addition of guanidine-HCI. Images FIGURE 2 PMID:8527683

  17. An Improved MUSIC Model for Gibbsite Surfaces

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mitchell, Scott C.; Bickmore, Barry R.; Tadanier, Christopher J.

    2004-06-01

    Here we use gibbsite as a model system with which to test a recently published, bond-valence method for predicting intrinsic pKa values for surface functional groups on oxides. At issue is whether the method is adequate when valence parameters for the functional groups are derived from ab initio structure optimization of surfaces terminated by vacuum. If not, ab initio molecular dynamics (AIMD) simulations of solvated surfaces (which are much more computationally expensive) will have to be used. To do this, we had to evaluate extant gibbsite potentiometric titration data that where some estimate of edge and basal surface area wasmore » available. Applying BET and recently developed atomic force microscopy methods, we found that most of these data sets were flawed, in that their surface area estimates were probably wrong. Similarly, there may have been problems with many of the titration procedures. However, one data set was adequate on both counts, and we applied our method of surface pKa int prediction to fitting a MUSIC model to this data with considerable success—several features of the titration data were predicted well. However, the model fit was certainly not perfect, and we experienced some difficulties optimizing highly charged, vacuum-terminated surfaces. Therefore, we conclude that we probably need to do AIMD simulations of solvated surfaces to adequately predict intrinsic pKa values for surface functional groups.« less

  18. Direct Measurement of Trace Elemental Mercury in Hydrocarbon Matrices by Gas Chromatography with Ultraviolet Photometric Detection.

    PubMed

    Gras, Ronda; Luong, Jim; Shellie, Robert A

    2015-11-17

    We introduce a technique for the direct measurement of elemental mercury in light hydrocarbons such as natural gas. We determined elemental mercury at the parts-per-trillion level with high precision [<3% RSD (n = 20 manual injection)] using gas chromatography with ultraviolet photometric detection (GC-UV) at 254 nm. Our approach requires a small sample volume (1 mL) and does not rely on any form of sample preconcentration. The GC-UV separation employs an inert divinylbenzene porous layer open tubular column set to separate mercury from other components in the sample matrix. We incorporated a 10-port gas-sampling valve in the GC-UV system, which enables automated sampling, as well as back flushing capability to enhance system cleanliness and sample throughput. Total analysis time is <2 min, and the procedure is linear over a range of 2-83 μg/m(3) [correlation coefficient of R(2) = 0.998] with a measured recovery of >98% over this range.

  19. Gas chromatography with flame photometric detection of 31 organophosphorus pesticide residues in Alpinia oxyphylla dried fruits.

    PubMed

    Zhao, Xiangsheng; Kong, Weijun; Wei, Jianhe; Yang, Meihua

    2014-11-01

    A simple, rapid and effective gas chromatography-flame photometric detection method was established for simultaneous multi-component determination of 31 organophosphorus pesticides (OPPs) residues in Alpinia oxyphylla, which is widely consumed as a traditional medicine and food in China. Sample preparation was completed in a single step without any clean-up procedure. All pesticides expressed good linear relationships between 0.004 and 1.0 μg/mL with correlation coefficients higher than 0.9973. The method gave satisfactory recoveries for most pesticides. The limits of detection varied from 1 to 10 ng/mL, and the limits of quantification (LOQs) were between 4 and 30 ng/mL. The proposed method was successfully applied to 55 commercial samples purchased from five different areas. Five pesticide residues were detected in four (7.27%) samples. The positive samples were confirmed by gas chromatography with tandem mass spectrometry (GC-MS/MS). Copyright © 2014 Elsevier Ltd. All rights reserved.

  20. The effect of photometric and geometric context on photometric and geometric lightness effects

    PubMed Central

    Lee, Thomas Y.; Brainard, David H.

    2014-01-01

    We measured the lightness of probe tabs embedded at different orientations in various contextual images presented on a computer-controlled stereo display. Two background context planes met along a horizontal roof-like ridge. Each plane was a graphic rendering of a set of achromatic surfaces with the simulated illumination for each plane controlled independently. Photometric context was varied by changing the difference in simulated illumination intensity between the two background planes. Geometric context was varied by changing the angle between them. We parsed the data into separate photometric effects and geometric effects. For fixed geometry, varying photometric context led to linear changes in both the photometric and geometric effects. Varying geometric context did not produce a statistically reliable change in either the photometric or geometric effects. PMID:24464163

  1. The effect of photometric and geometric context on photometric and geometric lightness effects.

    PubMed

    Lee, Thomas Y; Brainard, David H

    2014-01-24

    We measured the lightness of probe tabs embedded at different orientations in various contextual images presented on a computer-controlled stereo display. Two background context planes met along a horizontal roof-like ridge. Each plane was a graphic rendering of a set of achromatic surfaces with the simulated illumination for each plane controlled independently. Photometric context was varied by changing the difference in simulated illumination intensity between the two background planes. Geometric context was varied by changing the angle between them. We parsed the data into separate photometric effects and geometric effects. For fixed geometry, varying photometric context led to linear changes in both the photometric and geometric effects. Varying geometric context did not produce a statistically reliable change in either the photometric or geometric effects.

  2. A new approach to flow-batch titration. A monosegmented flow titrator with coulometric reagent generation and potentiometric or biamperometric detection.

    PubMed

    de Aquino, Emerson Vidal; Rohwedder, Jarbas José Rodrigues; Pasquini, Celio

    2006-11-01

    Monosegmented flow analysis (MSFA) has been used as a flow-batch system to produce a simple, robust, and mechanized titrator that enables true titrations to be performed without the use of standards. This paper also introduces the use of coulometry with monosegmented titration by proposing a versatile flow cell. Coulometric generation of the titrand is attractive for titrations performed in monosegmented systems, because the reagent can be added without increasing the volume of sample injected. Also, biamperomeric and potentiometric detection of titration end-points can increase the versatility of the monosegmented titrator. The cell integrates coulometric generation of the titrand with detection of end-point by potentiometry or biamperometry. The resulting titrator is a flow-batch system in which the liquid monosegment, constrained by the interfaces of the gaseous carrier stream, plays the role of a sample of known volume to be titrated. The system has been used for determination of ascorbic acid, by coulometric generation of I2 with biamperometric detection, and for determination of Fe(II), by coulometric generation of Ce(IV) with potentiometric detection of the end-point, both in feed supplements.

  3. Comparison of manual versus automatic continuous positive airway pressure titration and the development of a predictive equation for therapeutic continuous positive airway pressure in Chinese patients with obstructive sleep apnoea.

    PubMed

    Luo, Jiaying; Xiao, Sichang; Qiu, Zhihui; Song, Ning; Luo, Yuanming

    2013-04-01

    Whether the therapeutic nasal continuous positive airway pressure (CPAP) derived from manual titration is the same as derived from automatic titration is controversial. The purpose of this study was to compare the therapeutic pressure derived from manual titration with automatic titration. Fifty-one patients with obstructive sleep apnoea (OSA) (mean apnoea/hypopnoea index (AHI) = 50.6 ± 18.6 events/h) who were newly diagnosed after an overnight full polysomnography and who were willing to accept CPAP as a long-term treatment were recruited for the study. Manual titration during full polysomnography monitoring and unattended automatic titration with an automatic CPAP device (REMstar Auto) were performed. A separate cohort study of one hundred patients with OSA (AHI = 54.3 ± 18.9 events/h) was also performed by observing the efficacy of CPAP derived from manual titration. The treatment pressure derived from automatic titration (9.8 ± 2.2 cmH(2)O) was significantly higher than that derived from manual titration (7.3 ± 1.5 cmH(2)O; P < 0.001) in 51 patients. The cohort study of 100 patients showed that AHI was satisfactorily decreased after CPAP treatment using a pressure derived from manual titration (54.3 ± 18.9 events/h before treatment and 3.3 ± 1.7 events/h after treatment; P < 0.001). The results suggest that automatic titration pressure derived from REMstar Auto is usually higher than the pressure derived from manual titration. © 2013 The Authors. Respirology © 2013 Asian Pacific Society of Respirology.

  4. An interpretation of photometric parameters of bright desert regions of Mars and their dependence on wave length

    NASA Technical Reports Server (NTRS)

    Weaver, W. R.; Meador, W. E.

    1977-01-01

    Photometric data from the bright desert areas of Mars were used to determine the dependence of the three photometric parameters of the photometric function on wavelength and to provide qualitative predictions about the physical properties of the surface. Knowledge of the parameters allowed the brightness of these areas of Mars to be determined for any scattering geometry in the wavelength range of 0.45 to 0.70 micron. The changes that occur in the photometric parameters due to changes in wavelength were shown to be consistent with their physical interpretations, and the predictions of surface properties were shown to be consistent with conditions expected to exist in these regions of Mars. The photometric function was shown to have potential as a diagnostic tool for the qualitative determination of surface properties, and the consistency of the behavior of the photometric parameters was considered to be support for the validity of the photometric function.

  5. Searching for Extragalactic Sources in the VISTA Variables in the Vía Láctea Survey

    NASA Astrophysics Data System (ADS)

    Baravalle, Laura D.; Alonso, M. Victoria; Nilo Castellón, José Luis; Beamín, Juan Carlos; Minniti, Dante

    2018-01-01

    We search for extragalactic sources in the VISTA Variables in the Vía Láctea survey that are hidden by the Galaxy. Herein, we describe our photometric procedure to find and characterize extragalactic objects using a combination of SExtractor and PSFEx. It was applied in two tiles of the survey: d010 and d115, without previous extragalactic IR detections, in order to obtain photometric parameters of the detected sources. The adopted criteria to define extragalactic candidates include CLASSSTAR< 0.3; 1.0 < R1/2< 5.0 arcsec; 2.1 < C < 5 and Φ > 0.002 and the colors: 0.5 < (J–K s ) < 2.0 mag; 0.0 < (J–H) < 1.0 mag; 0.0 < (H–K s ) < 2.0 mag and (J–H) + 0.9 (H–K s ) > 0.44 mag. We detected 345 and 185 extragalactic candidates in the d010 and d115 tiles, respectively. All of them were visually inspected and confirmed to be galaxies. In general, they are small and more circular objects, due to the near-IR sensitivity to select more compact objects with higher surface brightness. The procedure will be used to identify extragalactic objects in other tiles of the VVV disk, which will allow us to study the distribution of galaxies and filaments hidden by the Milky Way.

  6. Reduction procedures for accurate analysis of MSX surveillance experiment data

    NASA Technical Reports Server (NTRS)

    Gaposchkin, E. Mike; Lane, Mark T.; Abbot, Rick I.

    1994-01-01

    Technical challenges of the Midcourse Space Experiment (MSX) science instruments require careful characterization and calibration of these sensors for analysis of surveillance experiment data. Procedures for reduction of Resident Space Object (RSO) detections will be presented which include refinement and calibration of the metric and radiometric (and photometric) data and calculation of a precise MSX ephemeris. Examples will be given which support the reduction, and these are taken from ground-test data similar in characteristics to the MSX sensors and from the IRAS satellite RSO detections. Examples to demonstrate the calculation of a precise ephemeris will be provided from satellites in similar orbits which are equipped with S-band transponders.

  7. Computer controlled titration with piston burette or peristaltic pump - a comparison.

    PubMed

    Hoffmann, W

    1996-09-01

    The advantages and problems of the use of piston burettes and peristaltic pumps for dosage of titrant solutions in automatic titrations are shown. For comparison, only the dosing devices were exchanged and all other components and conditions remained unchanged. The results of continuous acid base titration show good agreement and comparable reproducibility. Potentiometric sensors (glass electrodes) with different equilibration behaviour influence the results. The capability of such electrodes was tested. Conductometric measurements allow a much faster detection because there is no equilibration of electrodes. Piston burettes should be used for titration with very high precision, titration with organic solvents and slow titrations. Peristaltic pumps seem to be more suitable for continuous titrations and long time operation without service.

  8. 21 CFR 862.2160 - Discrete photometric chemistry analyzer for clinical use.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Discrete photometric chemistry analyzer for... Clinical Laboratory Instruments § 862.2160 Discrete photometric chemistry analyzer for clinical use. (a) Identification. A discrete photometric chemistry analyzer for clinical use is a device intended to duplicate...

  9. Sensitive methods for the titrimetric micro-determination of biological calcium and magnesium

    PubMed Central

    Beale, R. N.; Bostrom, J. O.

    1963-01-01

    New reagents containing high concentrations of urea are developed for micro-titration of calcium and magnesium, with ethylenediamine tetra-acetic acid (E.D.T.A.) as titrant and Corinth Ca (Plasmocorinth B) as indicator. Magnesium is determined as the difference between calcium plus magnesium and calcium. Quantitative aspects are studied, and accurate titration of untreated serum or urine is believed to be possible; precision is satisfactory. The methods are simple, robust, and suitable for routine use. Normal ranges are established for serum from blood donors of each sex. The mean serum calcium level for women is found to be lower than for men, while the mean magnesium contents are approximately the same. The latter appear to be somewhat lower than values found by flame emission spectrophotometry; in very good agreement with a mean value for plasma obtained by flame absorption spectrophotometry; and intermediate when compared with the values obtained by two other titrimetric procedures. PMID:13969919

  10. Determination of Carbonyl Functional Groups in Bio-oils by Potentiometric Titration: The Faix Method.

    PubMed

    Black, Stuart; Ferrell, Jack R

    2017-02-07

    Carbonyl compounds present in bio-oils are known to be responsible for bio-oil property changes upon storage and during upgrading. Specifically, carbonyls cause an increase in viscosity (often referred to as 'aging') during storage of bio-oils. As such, carbonyl content has previously been used as a method of tracking bio-oil aging and condensation reactions with less variability than viscosity measurements. Additionally, carbonyls are also responsible for coke formation in bio-oil upgrading processes. Given the importance of carbonyls in bio-oils, accurate analytical methods for their quantification are very important for the bio-oil community. Potentiometric titration methods based on carbonyl oximation have long been used for the determination of carbonyl content in pyrolysis bio-oils. Here, we present a modification of the traditional carbonyl oximation procedures that results in less reaction time, smaller sample size, higher precision, and more accurate carbonyl determinations. While traditional carbonyl oximation methods occur at room temperature, the Faix method presented here occurs at an elevated temperature of 80 °C.

  11. Protometric thermometric titrations of sparingly soluble compounds in water in the presence of n-octanol.

    PubMed

    Burgot, G; Burgot, J-L

    2002-10-15

    Thermometric titrimetry permits titration of acido-basic compounds in water in the presence of n-octanol. n-Octanol permits the solubilization of protolytes and moreover may also displace the equilibria of the titration reactions. Hydrochlorides of highly insoluble derivatives such as phenothiazine derivatives can be titrated with satisfactory accuracy and precision by sodium hydroxide despite their high pK(a) values. Likewise barbiturate salts can be titrated by hydrochloric acid. In the case of some salts, the methodology may permit the sequential titration of the ion and counter ion. Copyright 2002 Elsevier Science B.V.

  12. Risks and Benefits of Rapid Clozapine Titration.

    PubMed

    Lochhead, Jeannie D; Nelson, Michele A; Schneider, Alan L

    2016-05-18

    Clozapine is often considered the gold standard for the treatment of schizophrenia. Clinical guidelines suggest a gradual titration over 2 weeks to reduce the risks of adverse events such as seizures, hypotension, agranulocytosis, and myocarditis. The slow titration often delays time to therapeutic response. This raises the question of whether, in some patients, it may be safe to use a more rapid clozapine titration. The following case illustrates the potential risks associated with the use of multiple antipsychotics and rapid clozapine titration. We present the case of a young man with schizophrenia who developed life threatening neuroleptic malignant syndrome (NMS) during rapid clozapine titration and treatment with multiple antipsychotics. We were unable to find another case in the literature of NMS associated with rapid clozapine titration. This case is meant to urge clinicians to carefully evaluate the risks and benefits of rapid clozapine titration, and to encourage researchers to further evaluate the safety of rapid clozapine titration. Rapid clozapine titration has implications for decreasing health care costs associated with prolonged hospitalizations, and decreasing the emotional suffering associated with uncontrolled symptoms of psychosis. Clozapine is considered the most effective antipsychotic available thus efforts should focus on developing strategies that would allow for safest and most efficient use of clozapine to encourage its utilization for treatment resistance schizophrenia.

  13. Signal processing with a summing operational amplifier in multicomponent potentiometric titrations.

    PubMed

    Parczewski, A

    1987-06-01

    It has been proved that application of two indicator electrodes connected to the ordinary titration apparatus through an auxiliary electronic device (a summing operational amplifier) significantly extends the scope of multicomponent potentiometric titrations in which the analytes are determined simultaneously from a single titration curve. For each analyte there is a corresponding potential jump on the titration curve. By application of the proposed auxiliary device, the sum of the electrode potentials is measured. The device also enables the relative sizes of the potential jumps at the end-points on the titration curve to be varied. The advantages of the proposed signal processing are exemplified by complexometric potentiometric titrations of Fe(III) and Cu(II) in mixtures, with a platinum electrode and a copper ion-selective electrode as the indicator electrodes.

  14. Insights into optimal basal insulin titration in type 2 diabetes: Results of a quantitative survey.

    PubMed

    Berard, Lori; Bonnemaire, Mireille; Mical, Marie; Edelman, Steve

    2018-02-01

    Basal insulin (BI) treatment initiation and dose titration in type 2 diabetes (T2DM) are often delayed. Such "clinical inertia" results in poor glycaemic control and high risk of long-term complications. This survey aimed to determine healthcare professional (HCP) and patient attitudes to BI initiation and titration. An online survey (July-August 2015) including HCPs and patients with T2DM in the USA, France and Germany. Patients were ≥18 years old and had been on BI for 6 to 36 months, or discontinued BI within the previous 12 months. Participants comprised 386 HCPs and 318 people with T2DM. While >75% of HCPs reported discussing titration at the initiation visit, only 16% to 28% of patients remembered such discussions, many (32%-42%) were unaware of the need to titrate BI, and only 28% to 39% recalled mention of the time needed to reach glycaemic goals. Most HCPs and patients agreed that more effective support tools to assist BI initiation/titration are needed; patients indicated that provision of such tools would increase confidence in self-titration. HCPs identified fear of hypoglycaemia, failure to titrate in the absence of symptoms, and low patient motivation as important titration barriers. In contrast, patients identified weight gain, the perception that titration meant worsening disease, frustration over the time to reach HbA1c goals and fear of hypoglycaemia as major factors. A disconnect exists between HCP- and patient-perceived barriers to effective BI titration. To optimize titration, strategies should be targeted to improve HCP-patient communication, and provide support and educational tools. © 2017 The Authors. Diabetes, Obesity and Metabolism published by John Wiley & Sons Ltd.

  15. Insights into optimal basal insulin titration in type 2 diabetes: Results of a quantitative survey

    PubMed Central

    Bonnemaire, Mireille; Mical, Marie; Edelman, Steve

    2017-01-01

    Aims Basal insulin (BI) treatment initiation and dose titration in type 2 diabetes (T2DM) are often delayed. Such “clinical inertia” results in poor glycaemic control and high risk of long‐term complications. This survey aimed to determine healthcare professional (HCP) and patient attitudes to BI initiation and titration. Methods An online survey (July–August 2015) including HCPs and patients with T2DM in the USA, France and Germany. Patients were ≥18 years old and had been on BI for 6 to 36 months, or discontinued BI within the previous 12 months. Results Participants comprised 386 HCPs and 318 people with T2DM. While >75% of HCPs reported discussing titration at the initiation visit, only 16% to 28% of patients remembered such discussions, many (32%–42%) were unaware of the need to titrate BI, and only 28% to 39% recalled mention of the time needed to reach glycaemic goals. Most HCPs and patients agreed that more effective support tools to assist BI initiation/titration are needed; patients indicated that provision of such tools would increase confidence in self‐titration. HCPs identified fear of hypoglycaemia, failure to titrate in the absence of symptoms, and low patient motivation as important titration barriers. In contrast, patients identified weight gain, the perception that titration meant worsening disease, frustration over the time to reach HbA1c goals and fear of hypoglycaemia as major factors. Conclusion A disconnect exists between HCP‐ and patient‐perceived barriers to effective BI titration. To optimize titration, strategies should be targeted to improve HCP–patient communication, and provide support and educational tools. PMID:28719066

  16. Inactivation of the Hutchinson strain of non-A, non-B hepatitis virus by combined use of beta-propiolactone and ultraviolet irradiation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Prince, A.M.; Stephan, W.; Dichtelmueller, H.B.

    1985-06-01

    A beta-propiolactone/ultraviolet irradiation procedure (beta PL/UV) has been evaluated for its ability to inactivate 30,000 chimpanzee infectious doses of the Hutchinson strain of non-A, non-B (NANB) virus. The chimpanzees were inoculated with plasma to which this dose of the titrated virus had been added prior to application of the beta PL/UV process in accordance with a procedure used for licensed blood derivatives in Germany. Neither animal developed hepatitis. When subsequently challenged with the same contaminated plasma, which had not been sterilized, both animals promptly developed typical NANB hepatitis. This study extends the high (approximately 10(7)-fold) process efficiency of the betamore » PL/UV procedure previously reported for hepatitis B virus to a blood-borne NANB virus.« less

  17. Measurements of Physical Parameters of White Dwarfs: A Test of the Mass–Radius Relation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bédard, A.; Bergeron, P.; Fontaine, G., E-mail: bedard@astro.umontreal.ca, E-mail: bergeron@astro.umontreal.ca, E-mail: fontaine@astro.umontreal.ca

    We present a detailed spectroscopic and photometric analysis of 219 DA and DB white dwarfs for which trigonometric parallax measurements are available. Our aim is to compare the physical parameters derived from the spectroscopic and photometric techniques, and then to test the theoretical mass–radius relation for white dwarfs using these results. The agreement between spectroscopic and photometric parameters is found to be excellent, especially for effective temperatures, showing that our model atmospheres and fitting procedures provide an accurate, internally consistent analysis. The values of surface gravity and solid angle obtained, respectively, from spectroscopy and photometry, are combined with parallax measurementsmore » in various ways to study the validity of the mass–radius relation from an empirical point of view. After a thorough examination of our results, we find that 73% and 92% of the white dwarfs are consistent within 1 σ and 2 σ confidence levels, respectively, with the predictions of the mass–radius relation, thus providing strong support to the theory of stellar degeneracy. Our analysis also allows us to identify 15 stars that are better interpreted in terms of unresolved double degenerate binaries. Atmospheric parameters for both components in these binary systems are obtained using a novel approach. We further identify a few white dwarfs that are possibly composed of an iron core rather than a carbon/oxygen core, since they are consistent with Fe-core evolutionary models.« less

  18. Kinetics of bacterial potentiometric titrations: the effect of equilibration time on buffering capacity of Pantoea agglomerans suspensions.

    PubMed

    Kapetas, Leon; Ngwenya, Bryne T; Macdonald, Alan M; Elphick, Stephen C

    2011-07-15

    Several recent studies have made use of continuous acid-base titration data to describe the surface chemistry of bacterial cells as a basis for accurately modelling metal adsorption to bacteria and other biomaterials of potential industrial importance. These studies do not share a common protocol; rather they titrate in different pH ranges and they use different stability criteria to define equilibration time during titration. In the present study we investigate the kinetics of bacterial titrations and test the effect they have on the derivation of functional group concentrations and acidity constants. We titrated suspensions of Pantoea agglomerans by varying the equilibration time between successive titrant additions until stability of 0.1 or 0.001 mV s(-1) was attained. We show that under longer equilibration times, titration results are less reproducible and suspensions exhibit marginally higher buffering. Fluorescence images suggest that cell lysis is not responsible for these effects. Rather, high DOC values and titration reversibility hysterisis after long equilibration times suggest that variability in buffering is due to the presence of bacterial exudates, as demonstrated by titrating supernatants separated from suspensions of different equilibration times. It is recommended that an optimal equilibration time is always determined with variable stability control and preliminary reversibility titration experiments. Copyright © 2011 Elsevier Inc. All rights reserved.

  19. Rapid Clozapine Titration in Patients with Treatment Refractory Schizophrenia.

    PubMed

    Poyraz, Cana Aksoy; Özdemir, Armağan; Sağlam, Nazife Gamze Usta; Turan, Şenol; Poyraz, Burç Çağrı; Tomruk, Nesrin; Duran, Alaattin

    2016-06-01

    The aim of this study is to evaluate the safety and effectiveness of rapid clozapine titration in patients with schizophrenia in hospital settings. We conducted a retrospective two-center cohort study to compare the safety and effectiveness of clozapine with different titration rates in treatment-refractory patients with schizophrenia. In the first center, clozapine was started at 25-50 mg followed by 50-100 mg as needed every 6 h on day 1, followed by increases of 50-100 mg/day. In the second center, titration was slower; clozapine initiated with 12.5-50 mg on day 1 followed by increases of 25-50 mg/day. The number of days between starting of clozapine until discharge was shorter in the rapid titration group (22.4 ± 8.72 vs 27.0 ± 10.5, p = 0.1). Number of days of total hospital stay were significantly shorter in the rapid titration group (29.6 ± 10.6 vs 41.2 ± 14.8, p = 0.002). Hypotension was more common in the rapid titration group and one patient had suspected myocarditis. Rapid clozapine titration appeared safe and effective. The length of stay following initiation of clozapine was shorter in the rapid-titration group, although this was not statistically significant. However starting clozapine earlier together with rapid titration has significantly shortened the length of hospital stay in patients with treatment refractory schizophrenia.

  20. Reduction to Outside the Atmosphere and Statistical Tests Used in Geneva Photometry

    NASA Technical Reports Server (NTRS)

    Rufener, F.

    1984-01-01

    Conditions for creating a precise photometric system are investigated. The analytical and discriminatory potentials of a photometry obviously result from the localization of the passbands in the spectrum; they do, however, also depend critically on the precision attained. This precision is the result of two different types of precautions. Two procedures which contribute in an efficient manner to achieving greater precision are examined. These two methods are known as hardware related precision and software related precision.

  1. Safety and tolerability of different titration rates of retigabine (ezogabine) in patients with partial-onset seizures.

    PubMed

    Biton, Victor; Gil-Nagel, Antonio; Brodie, Martin J; Derossett, Sarah E; Nohria, Virinder

    2013-11-01

    Retigabine (RTG; international nonproprietary name)/ezogabine (EZG; US adopted name) is an antiepileptic drug (AED) that prolongs neuronal voltage-gated potassium-channel KCNQ2-5 (Kv 7.2-7.5) opening. This double-blind study evaluated different RTG/EZG dose-titration rates. Patients (N=73) with partial-onset seizures receiving concomitant AEDs were randomized to one of three titration groups, all of which were initiated at RTG/EZG 300mg/day divided into three equal doses. Fast-, medium-, and slow-titration groups received dose increments of 150mg/day every 2, 4, and 7 days, respectively, achieving the target dose of 1200mg/day after 13, 25, and 43 days, respectively. Safety assessments were performed throughout. Discontinuation rates due to treatment-emergent adverse events (TEAEs) were numerically higher in the fast- (10/23) and medium- (7/22) titration groups than in the slow-titration group (3/23) but statistical significance was achieved only for the high-titration group compared with the low-titration group (p=0.024). Stratified analysis, with concomitant AEDs divided into enzyme inducers (carbamazepine, phenytoin, oxcarbazepine) or noninducers, showed that the risk of discontinuation due primarily to TEAEs was significantly higher in the fast- (p=0.010) but not in the medium-titration group (p=0.078) when compared with the slow-titration group. Overall, the slow-titration rate appeared to be best tolerated and was used in further efficacy and safety studies with RTG/EZG. Copyright © 2013 Elsevier B.V. All rights reserved.

  2. 40 CFR Appendix A to Part 425 - Potassium Ferricyanide Titration Method

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 30 2014-07-01 2014-07-01 false Potassium Ferricyanide Titration..., App. A Appendix A to Part 425—Potassium Ferricyanide Titration Method Source The potassium... buffered sulfide solution is titrated with standard potassium ferricyanide solution in the presence of a...

  3. 40 CFR Appendix A to Part 425 - Potassium Ferricyanide Titration Method

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 31 2013-07-01 2013-07-01 false Potassium Ferricyanide Titration..., App. A Appendix A to Part 425—Potassium Ferricyanide Titration Method Source The potassium... buffered sulfide solution is titrated with standard potassium ferricyanide solution in the presence of a...

  4. Highly selective electrode for potentiometric analysis of methadone in biological fluids and pharmaceutical formulations.

    PubMed

    Ardeshiri, Moslem; Jalali, Fahimeh

    2016-06-01

    In order to develop a fast and simple procedure for methadone analysis in biological fluids, a graphite paste electrode (GPE) was modified with the ion-pair of methadone-phosphotungstic acid, and multiwalled carbon nanotubes (MWCNTs). Optimized composition of the electrode with respect to graphite powder:paraffin oil:MWCNTs:ion pair, was 58:30:8:4 (w/w%). The electrode showed a near-Nernstian slope of 58.9 ± 0.3 mV/decade for methadone in a wide linear range of 1.0 × 10(-8)-4.6 × 10(-3)M, with a detection limit of 1.0 × 10(-8)M. The electrode response was independent of pH in the range of 5-11, with a fast response time (~4s) at 25 °C. The sensor showed high selectivity and was successfully applied to the determination of sub-micromolar concentrations of methadone in human blood serum and urine samples, with recoveries in the range of 95-99.8%. The average recovery of methadone from tablets (5 mg/tablet) by using the proposed method was 98%. The life time of the modified electrode was more than 5 months, due to the characteristic of GPE which can be cut off and fresh electrode surface be available. A titration procedure was performed for methadone analysis by using phosphotungstic acid, as titrating agent, which showed an accurate end point and 1:1 stoichiometry for the ion-pair formed (methadone:phosphotungstic acid). The simple and rapid procedure as well as excellent detection limit and selectivity are some of the advantages of the proposed sensor for methadone. Copyright © 2016 Elsevier B.V. All rights reserved.

  5. Predictors of Arterial Blood Pressure Control During Deliberate Hypotension with Sodium Nitroprusside in Children

    PubMed Central

    Spielberg, David R; Barrett, Jeffrey S; Hammer, Gregory B; Drover, David R; Reece, Tammy; Cohane, Carol A; Schulman, Scott R

    2014-01-01

    Background Sodium nitroprusside (SNP) is used to decrease arterial blood pressure (BP) during certain surgical procedures. There are limited data regarding efficacy of BP control with SNP. There are no data on patient and clinician factors that affect BP control. We evaluated the dose-response relationship of SNP in infants and children undergoing major surgery and performed a quantitative assessment of BP control. Methods One hundred fifty-three subjects at 7 sites received a blinded infusion followed by open-label SNP during operative procedures requiring controlled hypotension. SNP was administered by continuous infusion and titrated to maintain BP control (mean arterial BP [MAP] within ±10% of clinician-defined target). BP was recorded using an arterial catheter. Statistical Process Control methodology was used to quantify BP control. A multivariable model assessed the effects of patient and procedural factors. Results BP was controlled an average 45.4% (SD 23.9%, 95% CI 41.5%-49.18%) of the time. Larger changes in infusion rate were associated with worse BP control (7.99% less control for 1 mcg•kg−•min− increase in average titration size, p=0.0009). A larger difference between a patient's baseline and target MAP predicted worse BP control (0.93% worse control per 1 mmHg increase in MAP difference, p=0.0013). Both effects persisted in multivariable models. Conclusions : SNP was effective in reducing BP. However, BP was within the target range less than half of the time. No clinician or patient factors were predictive of BP control, although two inverse relationships were identified. These relationships require additional study and may be best coupled with exposure-response modeling to propose improved dosing strategies when using SNP for controlled hypotension in the pediatric population. PMID:25099924

  6. Predictors of arterial blood pressure control during deliberate hypotension with sodium nitroprusside in children.

    PubMed

    Spielberg, David R; Barrett, Jeffrey S; Hammer, Gregory B; Drover, David R; Reece, Tammy; Cohane, Carol A; Schulman, Scott R

    2014-10-01

    Sodium nitroprusside (SNP) is used to decrease arterial blood pressure (BP) during certain surgical procedures. There are limited data regarding efficacy of BP control with SNP. There are no data on patient and clinician factors that affect BP control. We evaluated the dose-response relationship of SNP in infants and children undergoing major surgery and performed a quantitative assessment of BP control. One hundred fifty-three subjects at 7 sites received a blinded infusion followed by open-label SNP during operative procedures requiring controlled hypotension. SNP was administered by continuous infusion and titrated to maintain BP control (mean arterial BP [MAP] within ±10% of clinician-defined target). BP was recorded using an arterial catheter. Statistical process control methodology was used to quantify BP control. A multivariable model assessed the effects of patient and procedural factors. BP was controlled an average 45.4% (SD 23.9%; 95% CI, 41.5%-49.18%) of the time. Larger changes in infusion rate were associated with worse BP control (7.99% less control for 1 μg·kg·min increase in average titration size, P = 0.0009). A larger difference between a patient's baseline and target MAP predicted worse BP control (0.93% worse control per 1-mm Hg increase in MAP difference, P = 0.0013). Both effects persisted in multivariable models. SNP was effective in reducing BP. However, BP was within the target range less than half of the time. No clinician or patient factors were predictive of BP control, although 2 inverse relationships were identified. These relationships require additional study and may be best coupled with exposure-response modeling to propose improved dosing strategies when using SNP for controlled hypotension in the pediatric population.

  7. Data-driven, Interpretable Photometric Redshifts Trained on Heterogeneous and Unrepresentative Data

    NASA Astrophysics Data System (ADS)

    Leistedt, Boris; Hogg, David W.

    2017-03-01

    We present a new method for inferring photometric redshifts in deep galaxy and quasar surveys, based on a data-driven model of latent spectral energy distributions (SEDs) and a physical model of photometric fluxes as a function of redshift. This conceptually novel approach combines the advantages of both machine learning methods and template fitting methods by building template SEDs directly from the spectroscopic training data. This is made computationally tractable with Gaussian processes operating in flux-redshift space, encoding the physics of redshifts and the projection of galaxy SEDs onto photometric bandpasses. This method alleviates the need to acquire representative training data or to construct detailed galaxy SED models; it requires only that the photometric bandpasses and calibrations be known or have parameterized unknowns. The training data can consist of a combination of spectroscopic and deep many-band photometric data with reliable redshifts, which do not need to entirely spatially overlap with the target survey of interest or even involve the same photometric bands. We showcase the method on the I-magnitude-selected, spectroscopically confirmed galaxies in the COSMOS field. The model is trained on the deepest bands (from SUBARU and HST) and photometric redshifts are derived using the shallower SDSS optical bands only. We demonstrate that we obtain accurate redshift point estimates and probability distributions despite the training and target sets having very different redshift distributions, noise properties, and even photometric bands. Our model can also be used to predict missing photometric fluxes or to simulate populations of galaxies with realistic fluxes and redshifts, for example.

  8. Titration Curves: Fact and Fiction.

    ERIC Educational Resources Information Center

    Chamberlain, John

    1997-01-01

    Discusses ways in which datalogging equipment can enable titration curves to be measured accurately and how computing power can be used to predict the shape of curves. Highlights include sources of error, use of spreadsheets to generate titration curves, titration of a weak acid with a strong alkali, dibasic acids, weak acid and weak base, and…

  9. Simple and Automated Coulometric Titration of Acid Using Nonisolated Electrodes

    ERIC Educational Resources Information Center

    Kuntzleman, Thomas S.; Kenney, Joshua B.; Hasbrouck, Scott; Collins, Michael J.; Amend, John R.

    2011-01-01

    Coulometric titrations involve the quantification of analyte by measurements of current and time. In most coulometric titrations, the anode and cathode are placed in isolated cells that are connected by a salt bridge. By contrast, the experiments described here involve coulometric titrations (of acidic protons in solution) using a silver anode and…

  10. Natural monocrystalline pyrite as a sensor in non-aqueous solution Part I: Potentiometric titration of weak acids in, N,N-dimethylformamide, methylpyrrolidone and pyridine.

    PubMed

    Mihajlović, Lj V; Mihajlović, R P; Antonijević, M M; Vukanović, B V

    2004-11-15

    The possibility of applying natural monocrystaline pyrite as a sensor for the potentiometric titration of weak acids in N,N-dimethylformamide, methylpyrrolidone and pyridine was investigated. The potential of this electrode in N,N-dimethylformamide, methylpyrrolidone and pyridine exhibits a sub-Nernst dependence. In N,N-dimethylformamide the slope (mV/pH) is 39.0 and in methylpyrrolidone it is 45.0. The potential jumps at the titration end-point obtained in the titration of weak acids are higher than those obtained by the application of a glass electrode as the indicator electrode The potential in the course of the titration and at the titration end-point (TEP) are rapidly established. Sodium methylate, potassium hydroxide and tetrabutylammonium hydroxide (TBAH) proved to be very suitable titrating agents for these titrations. The results obtained in the determination of the investigated weak acids deviate by 0.1-0.35% with respect to those obtained by using a glass electrode as the indicator electrode.

  11. Corrosion Control Through a Better Understanding of the Metallic Substrate/Organic Coating/Interface.

    DTIC Science & Technology

    1981-11-01

    and the cyclohexane over molecular sieves, -79- pm NO pAalB hION fl i4a and then measuring the ppm of water in the cyclohexane using the Karl Fischer ... potentiometric titration using a method outlined by Bell [J. Polymer Sci. 8, 417-36 (1970)]. The procedure for epoxy groups involves the re- action with...with time, earliest stages of coating delamination, and secondary processes that occur was obtained by time lapse photography. Electrical methods are

  12. New insights on the accuracy of photometric redshift measurements

    NASA Astrophysics Data System (ADS)

    Massarotti, M.; Iovino, A.; Buzzoni, A.; Valls-Gabaud, D.

    2001-12-01

    We use the deepest and most complete redshift catalog currently available (the Hubble Deep Field (HDF) North supplemented by new HDF South redshift data) to minimize residuals between photometric and spectroscopic redshift estimates. The good agreement at zspec < 1.5 shows that model libraries provide a good description of the galaxy population. At zspec >= 2.0, the systematic shift between photometric and spectroscopic redshifts decreases when the modeling of the absorption by the interstellar and intergalactic media is refined. As a result, in the entire redshift range z in [0, 6], residuals between photometric and spectroscopic redshifts are roughly halved. For objects fainter than the spectroscopic limit, the main source of uncertainty in photometric redshifts is related to photometric errors, and can be assessed with Monte Carlo simulations.

  13. Potentiometric titration of metal ions in ethanol.

    PubMed

    Gibson, Graham T T; Mohamed, Mark F; Neverov, Alexei A; Brown, R S

    2006-09-18

    The potentiometric titrations of Zn2+, Cu2+ and 12 Ln3+ metal ions were obtained in ethanol to determine the titration constants (defined as the at which the [-OEt]/[Mx+]t ratios are 0.5, 1.5, and 2.5) and in two cases (La3+ and Zn2+) a complete speciation diagram. Several simple monobasic acids and aminium ions were also titrated to test the validity of experimental titration measurements and to establish new constants in this medium that will be useful for the preparation of buffers and standard solutions. The dependence of the titration constants on the concentration and type of metal ion and specific counterion effects is discussed. In selected cases, the titration profiles were analyzed using a commercially available fitting program to obtain information about the species present in solution, including La3+ for which a dimer model is proposed. The fitting provides the microscopic values for deprotonation of one to four metal-bound ethanol molecules. Kinetics for the La3+-catalyzed ethanolysis of paraoxon as a function of are presented and analyzed in terms of La3+ speciation as determined by the analysis of potentiometric titration curves. The stability constants for the formation of Zn2+ and Cu2+ complexes with 1,5,9-triazacyclododecane as determined by potentiometric titration are presented.

  14. Rapid Inpatient Titration of Intravenous Treprostinil for Pulmonary Arterial Hypertension: Safe and Tolerable.

    PubMed

    El-Kersh, Karim; Ruf, Kathryn M; Smith, J Shaun

    There is no standard protocol for intravenous treprostinil dose escalation. In most cases, slow up-titration is performed in the outpatient setting. However, rapid up-titration in an inpatient setting is an alternative that provides opportunity for aggressive treatment of common side effects experienced during dose escalation. In this study, we describe our experience with inpatient rapid up-titration of intravenous treprostinil. This was a single-center, retrospective study in which we reviewed the data of subjects with pulmonary arterial hypertension treated at our center who underwent inpatient rapid up-titration of intravenous treprostinil. Our treprostinil dose escalation protocol included initiation at 2 ng·kg·min with subsequent up-titration by 1 ng·kg·min every 6 to 8 hours as tolerated by side effects. A total of 16 subjects were identified. Thirteen subjects were treprostinil naive (naive group), and 3 subjects were receiving subcutaneous treprostinil but were hospitalized for further intravenous up-titration of treprostinil dose (nonnaive group). In the naive group, the median maximum dose achieved was 20 ng·kg·min with an interquartile range (IQR) of 20-23 ng·kg·min. The median up-titration interval was 6 days (IQR: 4-9). In the nonnaive group, the median maximum dose achieved was 20 ng·kg·min (range: 17-30). The median up-titration interval was 8.5 days (range: 1.5-11). Overall, the median maximum dose achieved was 20 ng·kg·min (IQR: 20-23.5), and the median up-titration interval was 6 days (IQR: 4.6-9.25), with no reported significant adverse hemodynamic events. In patients with pulmonary arterial hypertension, rapid inpatient titration of intravenous treprostinil is safe and tolerable.

  15. Dose titration of BAF312 attenuates the initial heart rate reducing effect in healthy subjects

    PubMed Central

    Legangneux, Eric; Gardin, Anne; Johns, Donald

    2013-01-01

    Aim Previous studies have shown transient decreases in heart rate (HR) following administration of sphingosine 1‐phosphate (S1P) receptor modulators including BAF312. This study was conducted to determine whether dose titration of BAF312 reduces or eliminates these effects. Methods Fifty‐six healthy subjects were randomized 1:1:1:1 to receive BAF312 in one of two dose titration (DT) regimens (DT1 and DT2: 0.25–10 mg over 9–10 days), no titration (10 mg starting dose) or placebo. Pharmacodynamic and pharmacokinetic parameters were assessed. Results Neither DT1 nor DT2 resulted in clinically significant bradycardia or atrioventricular conduction effects. Both titration regimens showed a favourable difference on each of days 1–12 vs. the non‐titration regimen on day 1 for HR effects (P < 0.0001). On day 1, the geometric mean ratio of the fraction from the previous day in minimum daily HR between DT1 and non‐titration was 1.18 (95% confidence interval [CI] 1.13, 1.23) and 1.14 (95% CI 1.09, 1.18) for DT2 (both P < 0.05) with significant differences noted through to day 12. Non‐titration HRs showed considerable separation from placebo throughout the study. There was no statistically significant reduction in HR vs. placebo on day 1 in either titration regimen. On days 3–7 subjects in DT1 and DT2 experienced minor reductions in HR vs. placebo (approximately 5 beats min−1; P ≤ 0.0001). From days 9–12, HRs in both titration regimens were comparable with placebo. Conclusion Both titration regimens effectively attenuated the initial bradyarrhythmia observed on day 1 of treatment with BAF312 10 mg. PMID:22845008

  16. Axitinib with or without dose titration for first-line metastatic renal-cell carcinoma: a randomised double-blind phase 2 trial.

    PubMed

    Rini, Brian I; Melichar, Bohuslav; Ueda, Takeshi; Grünwald, Viktor; Fishman, Mayer N; Arranz, José A; Bair, Angel H; Pithavala, Yazdi K; Andrews, Glen I; Pavlov, Dmitri; Kim, Sinil; Jonasch, Eric

    2013-11-01

    Population pharmacokinetic data suggest axitinib plasma exposure correlates with efficacy in metastatic renal-cell carcinoma. Axitinib dose titration might optimise exposure and improve outcomes. We prospectively assessed the efficacy and safety of axitinib dose titration in previously untreated patients with metastatic renal-cell carcinoma. In this randomised, double-blind, multicentre, phase 2 study, patients were enrolled from 49 hospitals and outpatient clinics in the Czech Republic, Germany, Japan, Russia, Spain, and USA. Patients with treatment-naive metastatic renal-cell carcinoma received axitinib 5 mg twice daily during a 4 week lead-in period. Those patients with blood pressure 150/90 mm Hg or lower, no grade 3 or 4 treatment-related toxic effects, no dose reductions, and no more than two antihypertensive drugs for 2 consecutive weeks were stratified by Eastern Cooperative Oncology Group performance status (0 vs 1), and then randomly assigned (1:1) to either masked titration with axitinib to total twice daily doses of 7 mg, and then 10 mg, if tolerated, or placebo titration. Patients who did not meet these criteria continued without titration. The primary objective was comparison of the proportion of patients achieving an objective response between randomised groups. Safety analyses were based on all patients who received at least one dose of axitinib. Between Sept 2, 2009, and Feb 28, 2011, we enrolled 213 patients, of whom 112 were randomly assigned to either the axitinib titration group (56 patients) or the placebo titration group (56 patients). 91 were not eligible for titration, and ten withdrew during the lead-in period. 30 patients (54%, 95% CI 40-67) in the axitinib titration group had an objective response, as did 19 patients (34%, 22-48]) in the placebo titration group (one-sided p=0·019). 54 (59%, 95% CI 49-70) of non-randomised patients achieved an objective response. Common grade 3 or worse, all-causality adverse events in treated patients were hypertension (ten [18%] of 56 in the axitinib titration group vs five [9%] of 56 in the placebo titration group vs 45 [49%] of 91 in the non-randomised group), diarrhoea (seven [13%] vs two [4%] vs eight [9%]), and decreased weight (four [7%] vs three [5%] vs six [7%]). One or more all-causality serious adverse events were reported in 15 (27%) patients in the axitinib titration group, 13 (23%) patients in the placebo titration group, and 35 (38%) non-randomised patients. The most common serious adverse events in all 213 patients were disease progression and dehydration (eight each [4%]), and diarrhoea, vomiting, pneumonia, and decreased appetite (four each [2%]). The greater proportion of patients in the axitinib titration group achieving an objective response supports the concept of individual axitinib dose titration in selected patients with metastatic renal-cell carcinoma. Axitinib shows clinical activity with a manageable safety profile in treatment-naive patients with this disease. Copyright © 2013 Elsevier Ltd. All rights reserved.

  17. DIFFERENTIAL THERMOMETRIC TITRATIONS AND THE DETERMINATION OF HEATS OF REACTION,

    DTIC Science & Technology

    TITRATION , THERMISTORS), (*HEAT OF REACTION, TITRATION ), SILVER COMPOUNDS, NITRATES, AMMONIA, PYRIDINES, ETHYLENEDIAMINE, AMINES, ALCOHOLS, BUTANOLS, PROPANOLS, SODIUM COMPOUNDS, HYDROXIDES, TEST METHODS

  18. Determination of carbonate carbon in geological materials by coulometric titration

    USGS Publications Warehouse

    Engleman, E.E.; Jackson, L.L.; Norton, D.R.

    1985-01-01

    A coulometric titration is used for the determination of carbonate carbon in geological materials. Carbon dioxide is evolved from the sample by the addition of 2 M perchloric acid, with heating, and is determined by automated coulometric titration. The coulometric titration showed improved speed and precision with comparable accuracy to gravimetric and gasometric techniques. ?? 1985.

  19. Simple Modification of Karl-Fischer Titration Method for Determination of Water Content in Colored Samples

    PubMed Central

    Tavčar, Eva; Turk, Erika; Kreft, Samo

    2012-01-01

    The most commonly used technique for water content determination is Karl-Fischer titration with electrometric detection, requiring specialized equipment. When appropriate equipment is not available, the method can be performed through visual detection of a titration endpoint, which does not enable an analysis of colored samples. Here, we developed a method with spectrophotometric detection of a titration endpoint, appropriate for moisture determination of colored samples. The reaction takes place in a sealed 4 ml cuvette. Detection is performed at 520 nm. Titration endpoint is determined from the graph of absorbance plotted against titration volume. The method has appropriate reproducibility (RSD = 4.3%), accuracy, and linearity (R 2 = 0.997). PMID:22567558

  20. Photometric requirements for portable changeable message signs.

    DOT National Transportation Integrated Search

    2001-09-01

    This project reviewed the performance of pchangeable message signs (PCMSs) and developed photometric standards to establish performance requirements. In addition, researchers developed photometric test methods and recommended them for use in evaluati...

  1. Positive end-expiratory pressure at minimal respiratory elastance represents the best compromise between mechanical stress and lung aeration in oleic acid induced lung injury.

    PubMed

    Carvalho, Alysson Roncally S; Jandre, Frederico C; Pino, Alexandre V; Bozza, Fernando A; Salluh, Jorge; Rodrigues, Rosana; Ascoli, Fabio O; Giannella-Neto, Antonio

    2007-01-01

    Protective ventilatory strategies have been applied to prevent ventilator-induced lung injury in patients with acute lung injury (ALI). However, adjustment of positive end-expiratory pressure (PEEP) to avoid alveolar de-recruitment and hyperinflation remains difficult. An alternative is to set the PEEP based on minimizing respiratory system elastance (Ers) by titrating PEEP. In the present study we evaluate the distribution of lung aeration (assessed using computed tomography scanning) and the behaviour of Ers in a porcine model of ALI, during a descending PEEP titration manoeuvre with a protective low tidal volume. PEEP titration (from 26 to 0 cmH2O, with a tidal volume of 6 to 7 ml/kg) was performed, following a recruitment manoeuvre. At each PEEP, helical computed tomography scans of juxta-diaphragmatic parts of the lower lobes were obtained during end-expiratory and end-inspiratory pauses in six piglets with ALI induced by oleic acid. The distribution of the lung compartments (hyperinflated, normally aerated, poorly aerated and non-aerated areas) was determined and the Ers was estimated on a breath-by-breath basis from the equation of motion of the respiratory system using the least-squares method. Progressive reduction in PEEP from 26 cmH2O to the PEEP at which the minimum Ers was observed improved poorly aerated areas, with a proportional reduction in hyperinflated areas. Also, the distribution of normally aerated areas remained steady over this interval, with no changes in non-aerated areas. The PEEP at which minimal Ers occurred corresponded to the greatest amount of normally aerated areas, with lesser hyperinflated, and poorly and non-aerated areas. Levels of PEEP below that at which minimal Ers was observed increased poorly and non-aerated areas, with concomitant reductions in normally inflated and hyperinflated areas. The PEEP at which minimal Ers occurred, obtained by descending PEEP titration with a protective low tidal volume, corresponded to the greatest amount of normally aerated areas, with lesser collapsed and hyperinflated areas. The institution of high levels of PEEP reduced poorly aerated areas but enlarged hyperinflated ones. Reduction in PEEP consistently enhanced poorly or non-aerated areas as well as tidal re-aeration. Hence, monitoring respiratory mechanics during a PEEP titration procedure may be a useful adjunct to optimize lung aeration.

  2. The impact of Narcotrend™ EEG-guided propofol administration on the speed of recovery from pediatric procedural sedation-A randomized controlled trial.

    PubMed

    Weber, Frank; Walhout, Laurence C; Escher, Johanna C

    2018-05-01

    Propofol is often used for procedural sedation in children undergoing gastrointestinal endoscopy. Reliable assessment of the depth of hypnosis during the endoscopic procedure is challenging. Processed electroencephalography using the Narcotrend Index can help titrating propofol to a predefined sedation level. The aim of this trial was to investigate the impact of Narcotrend Index-guided titration of propofol delivery on the speed of recovery. Children, aged 12-17 years, undergoing gastrointestinal endoscopy under procedural sedation, had propofol delivered via target controlled infusion either based on Narcotrend Index guidance (group NI) or standard clinical parameters (group C). Sedation was augmented with remifentanil in both study groups. The primary endpoint of this study was to compare the speed of fulfilling discharge criteria from the operating room between study groups. Major secondary endpoints were propofol consumption, discharge readiness from the recovery room, hypnotic depth as measured by the Narcotrend Index, and adverse events. Of the 40 children included, data were obtainable from 37. The time until discharge readiness from the operating room was shorter in group NI than in group C, with a difference between medians of 4.76 minutes [95%CI 2.6 to 7.4 minutes]. The same accounts for recovery room discharge times; difference between medians 4.03 minutes [95%CI 0.81 to 7.61 minutes]. Propofol consumption and the percentage of EEG traces indicating oversedation were higher in group C than in group NI. There were no significant adverse events in either study group. Narcotrend Index guidance of propofol delivery for deep sedation in children aged 12-17 years, underdoing gastrointestinal endoscopy results in faster recovery, less drug consumption, and fewer episodes of oversedation than dosing propofol according to clinical surrogate parameters of depth of hypnosis. The results of this study provide additional evidence in favor of the safety profile of propofol/remifentanil for procedural sedation in adequately selected pediatric patients. © 2018 The Authors. Pediatric Anesthesia Published by John Wiley & Sons Ltd.

  3. Gas chromatography with pulsed flame photometric detection multiresidue method for organophosphate pesticide and metabolite residues at the parts-per-billion level in representatives commodities of fruits and vegetable crop groups.

    PubMed

    Podhorniak, L V; Negron, J F; Griffith, F D

    2001-01-01

    A gas chromatographic method with a pulsed flame photometric detector (P-FPD) is presented for the analysis of 28 parent organophosphate (OP) pesticides and their OP metabolites. A total of 57 organophosphates were analyzed in 10 representative fruit and vegetable crop groups. The method is based on a judicious selection of known procedures from FDA sources such as the Pesticide Analytical Manual and Laboratory Information Bulletins, combined in a manner to recover the OPs and their metabolite(s) at the part-per-billion (ppb) level. The method uses an acetone extraction with either miniaturized Hydromatrix column partitioning or alternately a miniaturized methylene dichloride liquid-liquid partitioning, followed by solid-phase extraction (SPE) cleanup with graphitized carbon black (GCB) and PSA cartridges. Determination of residues is by programmed temperature capillary column gas chromatography fitted with a P-FPD set in the phosphorus mode. The method is designed so that a set of samples can be prepared in 1 working day for overnight instrumental analysis. The recovery data indicates that a daily column-cutting procedure used in combination with the SPE extract cleanup effectively reduces matrix enhancement at the ppb level for many organophosphates. The OPs most susceptible to elevated recoveries around or greater than 150%, based on peak area calculations, were trichlorfon, phosmet, and the metabolites of dimethoate, fenamiphos, fenthion, and phorate.

  4. Spectroscopic characterization of metal bound phytochelatin analogue (Glu-Cys)4-Gly.

    PubMed

    Cheng, Yongsheng; Yan, Yong-Bin; Liu, Jinyuan

    2005-10-01

    The metal ion binding properties of a phytochelatin (PC) analogue, (Glu-Cys)4-Gly (named as EC4), have been studied by a divalent metal ion binding assay monitored by UV-visible spectroscopy, circular dichroism and NMR spectroscopy. Spectro- photometric titration with different divalent metal ions have revealed that the stiochoimetry of metal-bound EC4 was 1:1, and its metal binding affinities with different divalent metal ions in the order of Cd(II)>Cu(II)>Zn(II)>Pb(II)>Ni(II)>Co(II). UV-visible spectroscopic analysis of metal complexes indicated that four sulfur atoms in cysteine residues are attributable to ligand-to-metal charge transfer (LMCT) between divalent metal ions and EC4, and further confirmed by 1D H1 NMR study and Circular Dichroism. In addition, Circular Dichroism spectra of both free and metal-bound forms of EC4 revealed that metal coordination drives the nonapeptide chain to fold into a turned conformation. The comprehensive analysis of spectroscopic properties of the nonapeptide complexed with metal ions not only provides a fundamental description of the metal ion binding properties of PC analogue, but also shows a correlation between metal binding affinity of PC analogue and the induction activity of metal ions.

  5. Structural and spectroscopic characterizations on the charge-transfer interactions of the second generation poly(propylene amine) dendrimers with iodine and picric acid acceptors

    NASA Astrophysics Data System (ADS)

    El-Sayed, Mohamed Y.; Refat, Moamen S.

    2015-02-01

    Herein, this study was focused to get a knowledge about the intermolecular charge transfer complexes between the second generation of poly(propylene amine) dendrimer (PPD2) with picric acid (PA) and iodine (I2) as π and σ-acceptors. The charge-transfer interaction of the PPD2 electron donor and the PA acceptor has been studied in CHCl3. The resulted data refereed to the formation of the new CT-complex with the general formula [(PPD2)(PA)4]. The 1:4 stoichiometry of the reaction was discussed upon the on elemental analysis and photometric titration. On the other hand, the 1:3½ iodine-PPD2 heptaiodide (I7-) charge-transfer complex has been studied spectrophotometrically in chloroform at room temperature with general formula [(PPD2)]+I7-. The electronic absorption bands of 2I2·I3- (I7-) are observed at 358 and 294 nm. Raman laser spectrum of the brown solid heptaiodide complex has two clearly vibration bands at 155 and 110 cm-1 due to symmetric stretching νs(Isbnd I) outer and inner bonds, respectively. The 1H NMR spectra and differential scanning calorimetry (DSC) data of PPD2 charge-transfer complexes were discussed.

  6. Synthesis, spectroscopic, thermal and antimicrobial investigations of charge-transfer complexes formed from the drug procaine hydrochloride with quinol, picric acid and TCNQ

    NASA Astrophysics Data System (ADS)

    Adam, Abdel Majid A.

    2012-12-01

    Intermolecular charge-transfer or proton-transfer complexes between the drug procaine hydrochloride (PC-HCl) as a donor and quinol (QL), picric acid (PA) or 7,7',8,8'-tetracyanoquinodimethane (TCNQ) as a π-acceptor have been synthesized and spectroscopically studied in methanol at room temperature. Based on elemental analyses and photometric titrations, the stoichiometry of the complexes (donor:acceptor molar ratios) was determined to be 1:1 for all three complexes. The formation constant (KCT), molar extinction coefficient (ɛCT) and other spectroscopic data have been determined using the Benesi-Hildebrand method and its modifications. The newly synthesized CT complexes have been characterized via elemental analysis, IR, Raman, 1H NMR, and electronic absorption spectroscopy. The morphological features of these complexes were investigated using scanning electron microscopy (SEM), and the sharp, well-defined Bragg reflections at specific 2θ angles have been identified from the powder X-ray diffraction patterns. Thermogravimetric analyses (TGAs) and kinetic thermodynamic parameters were also used to investigate the thermal stability of the synthesized solid CT complexes. Finally, the CT complexes were screened for their antibacterial and antifungal activities against various bacterial and fungal strains, and only the complex obtained using picric acid exhibited moderate antibacterial activity against all of the tested strains.

  7. Simulation analysis of photometric data for attitude estimation of unresolved space objects

    NASA Astrophysics Data System (ADS)

    Du, Xiaoping; Gou, Ruixin; Liu, Hao; Hu, Heng; Wang, Yang

    2017-10-01

    The attitude information acquisition of unresolved space objects, such as micro-nano satellites and GEO objects under the way of ground-based optical observations, is a challenge to space surveillance. In this paper, a useful method is proposed to estimate the SO attitude state according to the simulation analysis of photometric data in different attitude states. The object shape model was established and the parameters of the BRDF model were determined, then the space object photometric model was established. Furthermore, the photometric data of space objects in different states are analyzed by simulation and the regular characteristics of the photometric curves are summarized. The simulation results show that the photometric characteristics are useful for attitude inversion in a unique way. Thus, a new idea is provided for space object identification in this paper.

  8. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Leistedt, Boris; Hogg, David W., E-mail: boris.leistedt@nyu.edu, E-mail: david.hogg@nyu.edu

    We present a new method for inferring photometric redshifts in deep galaxy and quasar surveys, based on a data-driven model of latent spectral energy distributions (SEDs) and a physical model of photometric fluxes as a function of redshift. This conceptually novel approach combines the advantages of both machine learning methods and template fitting methods by building template SEDs directly from the spectroscopic training data. This is made computationally tractable with Gaussian processes operating in flux–redshift space, encoding the physics of redshifts and the projection of galaxy SEDs onto photometric bandpasses. This method alleviates the need to acquire representative training datamore » or to construct detailed galaxy SED models; it requires only that the photometric bandpasses and calibrations be known or have parameterized unknowns. The training data can consist of a combination of spectroscopic and deep many-band photometric data with reliable redshifts, which do not need to entirely spatially overlap with the target survey of interest or even involve the same photometric bands. We showcase the method on the i -magnitude-selected, spectroscopically confirmed galaxies in the COSMOS field. The model is trained on the deepest bands (from SUBARU and HST ) and photometric redshifts are derived using the shallower SDSS optical bands only. We demonstrate that we obtain accurate redshift point estimates and probability distributions despite the training and target sets having very different redshift distributions, noise properties, and even photometric bands. Our model can also be used to predict missing photometric fluxes or to simulate populations of galaxies with realistic fluxes and redshifts, for example.« less

  9. Passive haemagglutination test for antibodies against rabies virus*

    PubMed Central

    Gough, P. M.; Dierks, R. E.

    1971-01-01

    All the procedures now available for the measurement of rabies virus antibodies in serum have certain disadvantages. The serum neutralization test (SN), whether carried out by assay in mice or by the plaque-reduction technique, requires several days before the titrations are completed, necessitates special facilities for keeping large numbers of animals and tissue-culture plates, and is relatively expensive. A complement-fixation test is very insensitive, giving low titres in comparison with SN tests, and a haemagglutination-inhibition procedure is complicated by the presence of nonspecific reactions. A rabies passive haemagglutination technique (RPHA), developed to overcome many of these problems, is described. Titres obtained with human sera by the RPHA procedure correlated well with those obtained by SN tests. Both IgG and IgM classes of antibodies were measured by the RPHA procedure; however, it appeared to be more sensitive for detecting IgM than was the SN test and, therefore, gave higher titres for this class of immunoglobulins. PMID:5317009

  10. Dust in emission nebulae of the LMC derived from photometric reddening of stars

    NASA Astrophysics Data System (ADS)

    Greve, A.; van Genderen, A. M.; Laval, A.

    1990-10-01

    VBLUW photometric observations of stars in emission nebulae of the LMC are reported. The luminosities and extinctions of the stars are derived. Agreement is found between the average photometric extinctions of the nebulae and the extinctions derived from the Balmer line decrement measured by Caplan and Deharveng (1985 and 1986). The photometric extinctions are shown in the CO map of the LMC (Cohen et al., 1988).

  11. A Photometric redshift galaxy catalog from the Red-Sequence Cluster Survey

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hsieh, Bau-Ching; /Taiwan, Natl. Central U. /Taipei, Inst. Astron. Astrophys.; Yee, H.K.C.

    2005-02-01

    The Red-Sequence Cluster Survey (RCS) provides a large and deep photometric catalog of galaxies in the z' and R{sub c} bands for 90 square degrees of sky, and supplemental V and B data have been obtained for 33.6 deg{sup 2}. They compile a photometric redshift catalog from these 4-band data by utilizing the empirical quadratic polynomial photometric redshift fitting technique in combination with CNOC2 and GOODS/HDF-N redshift data. The training set includes 4924 spectral redshifts. The resulting catalog contains more than one million galaxies with photometric redshifts < 1.5 and R{sub c} < 24, giving an rms scatter {delta}({Delta}z)

  12. Implementation of a pharmacist-managed heart failure medication titration clinic.

    PubMed

    Martinez, Amanda S; Saef, Jerold; Paszczuk, Anna; Bhatt-Chugani, Hetal

    2013-06-15

    The development, implementation, and initial results of a pharmacist-managed heart failure (HF) medication titration clinic are described. In a quality-improvement initiative at a Veterans Affairs health care system, clinical pharmacists were incorporated into the hospital system's interprofessional outpatient HF clinic. In addition, a separate pharmacist-managed HF medication titration clinic was established, in which pharmacists were granted an advanced scope of practice and prescribing privileges, enabling them to initiate and adjust medication dosages under specific protocols jointly established by cardiology and pharmacy staff. Pharmacists involved in the titration clinic tracked patients' daily body weight, vital signs, and volume status using telephone-monitoring technology and via patient interviews. A retrospective chart review comparing achievement of target doses of angiotensin-converting enzyme inhibitor (ACEI), angiotensin-receptor blocker (ARB), and β-blocker therapies in a group of patients (n = 28) whose dosage titrations were carried out by nurses or physicians prior to implementation of the pharmacist-managed HF medication titration clinic and a group of patients (n = 27) enrolled in the medication titration clinic during its first six months of operation indicated that target ACEI and ARB doses were achieved in a significantly higher percentage of pharmacist-managed titration clinic enrollees (52.9% versus 31%, p = 0.007). Patients enrolled in the pharmacist-managed HF medication titration clinic also had a significantly higher rate of attainment of optimal β-blocker doses (49% versus 24.7%, p = 0.012). Implementation of a pharmacist-managed HF medication titration clinic increased the percentage of patients achieving optimal ACEI, ARB, and β-blocker dosages.

  13. Improved Photometry for the DASCH Pipeline

    NASA Astrophysics Data System (ADS)

    Tang, Sumin; Grindlay, Jonathan; Los, Edward; Servillat, Mathieu

    2013-07-01

    The Digital Access to a Sky Century@Harvard (DASCH) project is digitizing the ˜500,000 glass plate images obtained (full sky) by the Harvard College Observatory from 1885 to 1992. Astrometry and photometry for each resolved object are derived with photometric rms values of ˜0.15 mag for the initial photometry analysis pipeline. Here we describe new developments for DASCH photometry, applied to the Kepler field, that have yielded further improvements, including better identification of image blends and plate defects by measuring image profiles and astrometric deviations. A local calibration procedure using nearby stars in a similar magnitude range as the program star (similar to what has been done for visual photometry from the plates) yields additional improvement for a net photometric rms of ˜0.1 mag. We also describe statistical measures of light curves that are now used in the DASCH pipeline processing to identify new variables autonomously. The DASCH photometry methods described here are used in the pipeline processing for the data releases of DASCH data,5 as well as for a forthcoming paper on the long-term variables discovered by DASCH in the Kepler field.

  14. VVV Survey Search for Habitable Planets around M Dwarfs

    NASA Astrophysics Data System (ADS)

    Minniti, Dante

    2015-08-01

    VISTA Variables in the Vía Láctea (VVV) is a public ESO near- infrared (near-IR) variability survey aimed at scanning the Milky Way Bulge and an adjacent section of the mid-plane. The survey covers an area of 562 sqdeg in the Galactic bulge and the southern disk, containing a billion point sources. In this work we discuss the selection of nearby M-type dwarf stars using multicolor cuts. The ZYJHKs photometry allows an accurate estimation of the spectral types of the M-dwarf candidates. Our procedure is applied for fields located far from the Galactic center where the photometric quality is best. The results of this search covering 15 sqdeg allow us to estimate the total number of M-dwarfs that can be photometrically monitored in the VVV database. In addition, we analyze the light curves of the ~10000 best candidate M-dwarf stars searching for extrasolar planetary transits. In this poster we present the light curves of a hundred good transit candidates, and select those that lie in the HZ around their parent stars.

  15. Thermometric titration of cadmium with sodium diethyldithiocarbamate, with oxidation by hydrogen peroxide as indicator reaction.

    PubMed

    Hattori, T; Yoshida, H

    1987-08-01

    A new method of end-point indication is described for thermometric titration of cadmium with sodium diethyldithiocarbamate (DDTC). It is based on the redox reaction between hydrogen peroxide added to the system before titration, and the first excess of DDTC. Amounts of cadmium in the range 10-50 mumoles are titrated within 1% error.

  16. The Acid-Base Titration of a Very Weak Acid: Boric Acid

    ERIC Educational Resources Information Center

    Celeste, M.; Azevedo, C.; Cavaleiro, Ana M. V.

    2012-01-01

    A laboratory experiment based on the titration of boric acid with strong base in the presence of d-mannitol is described. Boric acid is a very weak acid and direct titration with NaOH is not possible. An auxiliary reagent that contributes to the release of protons in a known stoichiometry facilitates the acid-base titration. Students obtain the…

  17. Comparison of the clinical outcomes between unattended home APAP and polysomnography manual titration in obstructive sleep apnea patients.

    PubMed

    Wongsritrang, Krongthong; Fueangkamloon, Sumet

    2013-09-01

    To compare the clinical outcomes and determine the difference in therapeutic pressure between Automatic positive airway pressure (APAP) and polysomnography manual titration. Fifty patients of obstructive sleep apnea (OSA), moderate to severe cases, were randomized into two groups of intervention: 95-percentile pressure derived from APAP titration and an optimal pressure derived from manual titration. Clinical outcomes were assessed before and after four weeks. The average 95-percentile pressure derived from APAP titration was 11.7 +/- 0.3 cmH2O with median mask leak 1.3 L/min. The average optimal pressure derived from manual titration was 8.2 +/- 0.3 cmH2O. Pearson correlation analysis showed weak positive correlation (r = 0.336, p = 0.017). The Epworth Sleepiness Score (ESS), Quality of life tests: PSQI (Pittsburg Sleep Quality Index), and SF-36 (Medical Outcomes Study 36-Item Short-Form Health Survey) were improved significantly in both groups, but there were no statistical significant differences between groups. An APAP titration is an effective method of pressure determination for conventional CPAP therapy and shows no difference in clinical outcomes comparing the standard titration.

  18. Philosophy and updating of the asteroid photometric catalogue

    NASA Technical Reports Server (NTRS)

    Magnusson, Per; Barucci, M. Antonietta; Capria, M. T.; Dahlgren, Mats; Fulchignoni, Marcello; Lagerkvist, C. I.

    1992-01-01

    The Asteroid Photometric Catalogue now contains photometric lightcurves for 584 asteroids. We discuss some of the guiding principles behind it. This concerns both observers who offer input to it and users of the product.

  19. Charge characteristics of humic and fulvic acids: comparative analysis by colloid titration and potentiometric titration with continuous pK-distribution function model.

    PubMed

    Bratskaya, S; Golikov, A; Lutsenko, T; Nesterova, O; Dudarchik, V

    2008-09-01

    Charge characteristics of humic and fulvic acids of a different origin (inshore soils, peat, marine sediments, and soil (lysimetric) waters) were evaluated by means of two alternative methods - colloid titration and potentiometric titration. In order to elucidate possible limitations of the colloid titration as an express method of analysis of low content of humic substances we monitored changes in acid-base properties and charge densities of humic substances with soil depth, fractionation, and origin. We have shown that both factors - strength of acidic groups and molecular weight distribution in humic and fulvic acids - can affect the reliability of colloid titration. Due to deviations from 1:1 stoichiometry in interactions of humic substances with polymeric cationic titrant, the colloid titration can underestimate total acidity (charge density) of humic substances with domination of weak acidic functional groups (pK>6) and high content of the fractions with molecular weight below 1kDa.

  20. The photometric functions of Phobos and Deimos. II - Surface photometry of Deimos

    NASA Technical Reports Server (NTRS)

    Noland, M.; Veverka, J.

    1977-01-01

    Mariner 9 television pictures of Deimos are used to study the uniformity of a certain photometric scattering parameter over the surface of the satellite. It is shown that the photometric data considered satisfy the reciprocity principle and that the Hapke-Irvine scattering law is adequate for describing the surface. Phase functions for Deimos are obtained from scans along the photometric equator, and the photometric behavior of the brightest and darkest areas on the satellite's disk is examined. The results indicate that the surface of Deimos is covered uniformly by a dark and texturally complex material whose photometric behavior is well-represented by the Hapke-Irvine law, that the intrinsic phase coefficient of this material is about 0.017 mag/deg over the phase-angle range from 20 to 80 deg, and that slightly brighter material is present near some craters. Since enhanced brightening was not observed at the specular point of the photometric equator in any of the pictures studied, it is concluded that large exposures of solid rock are absent from the Mars-facing side of Deimos.

  1. Axitinib with or without dose titration for first-line metastatic renal-cell carcinoma: a randomised double-blind phase 2 trial

    PubMed Central

    Rini, Brian I; Melichar, Bohuslav; Ueda, Takeshi; GrÜnwald, Viktor; Fishman, Mayer N; Arranz, José A; Bair, Angel H; Pithavala, Yazdi K; Andrews, Glen I; Pavlov, Dmitri; Kim, Sinil; Jonasch, Eric

    2014-01-01

    Summary Background Population pharmacokinetic data suggest axitinib plasma exposure correlates with efficacy in metastatic renal-cell carcinoma. Axitinib dose titration might optimise exposure and improve outcomes. We prospectively assessed the efficacy and safety of axitinib dose titration in previously untreated patients with metastatic renal-cell carcinoma. Methods In this randomised, double-blind, multicentre, phase 2 study, patients were enrolled from 49 hospitals and outpatient clinics in the Czech Republic, Germany, Japan, Russia, Spain, and USA. Patients with treatment-naive metastatic renal-cell carcinoma received axitinib 5 mg twice daily during a 4 week lead-in period. Those patients with blood pressure 150/90 mm Hg or lower, no grade 3 or 4 treatment-related toxic effects, no dose reductions, and no more than two antihypertensive drugs for 2 consecutive weeks were stratified by Eastern Cooperative Oncology Group performance status (0 vs 1), and then randomly assigned (1:1) to either masked titration with axitinib to total twice daily doses of 7 mg, and then 10 mg, if tolerated, or placebo titration. Patients who did not meet these criteria continued without titration. The primary objective was comparison of the proportion of patients achieving an objective response between randomised groups. Safety analyses were based on all patients who received at least one dose of axitinib. This ongoing trial is registered with ClinicalTrials.gov, number NCT00835978. Findings Between Sept 2, 2009, and Feb 28, 2011, we enrolled 213 patients, of whom 112 were randomly assigned to either the axitinib titration group (56 patients) or the placebo titration group (56 patients). 91 were not eligible for titration, and ten withdrew during the lead-in period. 30 patients (54%, 95% CI 40–67) in the axitinib titration group had an objective response, as did 19 patients (34%, 22–48]) in the placebo titration group (one-sided p=0·019). 54 (59%, 95% CI 49–70) of non-randomised patients achieved an objective response. Common grade 3 or worse, all-causality adverse events in treated patients were hypertension (ten [18%] of 56 in the axitinib titration group vs five [9%] of 56 in the placebo titration group vs 45 [49%] of 91 in the non-randomised group), diarrhoea (seven [13%] vs two [4%] vs eight [9%]), and decreased weight (four [7%] vs three [5%] vs six [7%]). One or more all-causality serious adverse events were reported in 15 (27%) patients in the axitinib titration group, 13 (23%) patients in the placebo titration group, and 35 (38%) non-randomised patients. The most common serious adverse events in all 213 patients were disease progression and dehydration (eight each [4%]), and diarrhoea, vomiting, pneumonia, and decreased appetite (four each [2%]). Interpretation The greater proportion of patients in the axitinib titration group achieving an objective response supports the concept of individual axitinib dose titration in selected patients with metastatic renal-cell carcinoma. Axitinib shows clinical activity with a manageable safety profile in treatment-naive patients with this disease. Funding Pfizer Inc. PMID:24140184

  2. Titration Techniques

    NASA Astrophysics Data System (ADS)

    Jacobsen, Jerrold J.; Houston Jetzer, Kelly; Patani, Néha; Zimmerman, John; Zweerink, Gerald

    1995-07-01

    Significant attention is paid to the proper technique for reading a meniscus. Video shows meniscus-viewing techniques for colorless and dark liquids and the consequences of not reading a meniscus at eye level. Lessons are provided on approaching the end point, focusing on end point colors produced via different commonly used indicators. The concept of a titration curve is illustrated by means of a pH meter. Carefully recorded images of the entire range of meniscus values in a buret, pipet, and graduated cylinder are included so that you can show your students, in lecture or pre-lab discussion, any meniscus and discuss how to read the buret properly. These buret meniscus values are very carefully recorded at the rate of one video frame per hundredth of a milliliter, so that an image showing any given meniscus value can be obtained. These images can be easily incorporated into a computer-based multimedia environment for testing or meniscus-reading exercises. Two of the authors have used this technique and found the exercise to be very well received by their students. Video on side two shows nearly 100 "bloopers", demonstrating both the right way and wrong ways to do tasks associated with titration. This material can be used in a variety of situations: to show students the correct way to do something; to test students by asking them "What is this person doing wrong?"; or to develop multimedia, computer-based lessons. The contents of Titration Techniques are listed below: Side 1 Titration: what it is. A simple titration; Acid-base titration animation; A brief redox titration; Redox titration animation; A complete acid-base titration. Titration techniques. Hand technique variations; Stopcock; Using a buret to measure liquid volumes; Wait before reading meniscus; Dirty and clean burets; Read meniscus at eye level (see Fig. 1); Meniscus viewing techniques--light colored liquids; Meniscus viewing techniques--dark liquids; Using a magnetic stirrer; Rough titration; Significant figures; Approaching the end point; End point colors; Titration with a pH meter; Titration curves; Colors of indicators. Meniscus values. Buret meniscus values; Pipet meniscus values; Graduated cylinder meniscus values. Side 2"Bloopers". Introducing the people; Titration animation; Inspecting the buret; Rinsing the buret with water; Preparing a solid sample; Obtaining a liquid sample; Delivering a liquid sample with a Mohr pipet; Pipetting a liquid sample with a Mohr pipet; Rinsing the Mohr pipet with sample; Using the Mohr pipet to transfer sample; Delivering a liquid sample with a volumetric pipet; Pipetting a liquid sample with a volumetric pipet; Rinsing the volumetric pipet with sample; Using the volumetric pipet to transfer sample; Obtaining the titrant; Rinsing the buret with titrant; Filling the buret with titrant; Adding the indicator; The initial reading; Beginning the titration; Delivering titrant; The final reading. Figure 3. Near the end point a single drop of titrant can cause a lasting color change.

  3. Uncovering multiple populations in NGC 7099 (M 30) using Washington photometry

    NASA Astrophysics Data System (ADS)

    Frelijj, H.; Geisler, D.; Cummings, J.; Cohen, R. E.; Mauro, F.; Munoz, C.; Villanova, S.; Tang, B.

    2017-12-01

    Over the last decade, the classical definition of globular clusters (GCs) as simple stellar populations was revolutionized due to the discovery of 'multiple populations' (MPs). However, our knowledge of this phenomenon and its characteristics is still lacking greatly observationally, and there is currently no scenario which adequately explains its origin. It is therefore important to study as many GCs as possible to characterize whether or not they have MPs, and determine their detailed behaviour to enlighten formation scenarios, using a wide range of techniques. The Washington photometric system has proved to be useful to find MPs, thanks mainly to the ultraviolet (UV)-sensitivity and high efficiency of the C filter. We search for MPs in the Galactic GC NGC 7099 (M30), the second GC being searched for MPs using this system. We obtained photometric data using the Swope 1-m telescope at Las Campanas Observatory, as well as the 4-m SOAR facility. Our reduction procedure included Addstar experiments to properly assess photometric errors. We find a clear signal of MPs based on an intrinsically wide colour spread on the RGB, in particular due to a relatively small fraction of stars significantly bluer than the main RGB locus. These stars should correspond to so-called first-generation stars, which we estimate to be roughly 15 per cent of the total. However, we find these first-generation stars to be more spatially concentrated than their second-generation counterparts, which is the opposite to the general trend found in other clusters. We briefly discuss possible explanations for this phenomenon.

  4. The Montsec Observatory and the Gaia science alerts

    NASA Astrophysics Data System (ADS)

    Carrasco, J. M.; Burgaz, U.; Vilardell, F.; Jordi, C.

    2017-03-01

    The continuous and reiterative scan of the whole sky performed by Gaia ESA's mission during its (at least) 5 years of mission allows to detect transient events (e.g., supernovae, microlensing events, cataclysmic variables, etc) almost in real time among the daily millions of observations. The pipeline in charge to discover these alerts does a quick look analysis of the daily data stream, identify those sources increasing their brightness with respect to previous Gaia observations and also analyse their spectrophotometry to decide if those sources are good candidates to be published as a Gaia Photometric Science Alerts. These events are publicly announced for follow-up observations (both photometric and spectroscopic are needed). Observatories around the world confirm, classify and study them in detail. Observations are put in common and analysed together in a common interface in order to get a single analysis as detailed and precise as possible. Our team in Barcelona contributes to this Gaia science alerts follow-up programme with the 0.8 m robotic telescope Joan Oró (TJO), at the Montsec Observatory (OAdM), located at Sant Esteve de la Sarga (Lleida, Spain) performing photometric observations to derive the lightcurves of the most interesting alerts accessible from the observatory. Until now we have contributed with about 4500 images in multicolour Johnson-Cousins passbands obtained with TJO for a total of 38 Gaia science alerts, becoming the third most contributing observatory in the programme. Here we summarise the procedure to select new targets to be observed by TJO, submit follow-up observations and we explain the analysis we did for some interesting obtained lightcurves.

  5. Opening the Window on Galaxy Assembly: Ages and Structural Parameters of Globular Clusters Towards the Galactic Bulge

    NASA Astrophysics Data System (ADS)

    Cohen, Roger

    2015-10-01

    The primary aim of this program is to undertake a systematic investigation of highly reddened Galactic globular clusters (GGCs) located towards the Galactic bulge. These clusters have been excluded from deep space-based photometric surveys due to their severe total and differential extinction. We will exploit the photometric depth and homogeneity of two existing Treasury programs (the ACS GGC Treasury Survey and the WFC3 Bulge Treasury Program) along with the unique optical+IR parallel imaging capabilities of HST to finally place the bulge GGCs in the context of their optically well-studied counterparts. Specifically, by leveraging ACS/WFC together with WFC3/IR, we first exploit the reddening sensitivity at optical wavelengths to map severe, small-scale differential reddening in the cluster cores. Corrected two-color WFC3/IR photometry will then be used to measure cluster ages to better than 1 Gyr relative precision, finally completing the age-metallicity relation of the Milky Way GGC system. Ages are obtained using a demonstrated procedure which is strictly differential, and therefore insensitive to total distance, reddening, reddening law, or photometric calibration uncertainties. At the same time, deep archival Treasury survey imaging of the Galactic bulge will be used to decontaminate cluster luminosity functions, yielding measurements of bulge GGC mass functions and mass segregation on par with results from the ACS GGC Treasury survey. Finally, the imaging which we propose will be combined with existing wide-field near-IR PSF photometry, yielding complete radial number density profiles, structural and morphological parameters.

  6. Initial Evaluation of a Titration Appliance for Temporary Treatment of Obstructive Sleep Apnea.

    PubMed

    Levendowski, Daniel J; Morgan, Todd; Westbrook, Philip

    2012-01-01

    Custom oral appliances that adjustably advance the mandible provide superior outcomes when treating patients with moderate or severe sleep apnea. Custom appliances, however, are expensive, must be fitted by a dentist, and the likelihood of successful outcomes are difficult to predict. An inexpensive trial appliance, if proven efficacious, might be used to predict custom appliance outcomes or to provide temporary therapeutic benefit. The aim of this initial study was to assess the treatment efficacy of a novel titration oral appliance with that of an optimized custom appliance. Seventeen patients, treated with a custom oral appliance for at least one year, successfully completed a three-night home sleep test. The baseline obstructive sleep apnea severity was established on Night 1 with seven patients exhibiting severe, six moderate and four mild apnea/hypopnea indexes. Patients were randomly assigned to wear their custom appliance or the titration appliance on Nights 2 and 3. Significant reductions in the mean overall and supine apnea indexes (p < 0.05), and the overall (p < 0.01) and supine (p < 0.05) apnea/hypopnea indexes were observed for both the titration and custom appliances. The proportion of patients who exhibited at least a 50% reduction in the overall apnea index and supine apnea/hypopnea were similar for the titration and custom appliance (~60%). The custom appliance reduced the overall apnea/hypopnea index by 50% in a greater proportion of the patients compared to the titration appliance (77% vs. 53%). The titration appliance significantly reduced the degree of hypoxic exposure across sleep disordered breathing events overall (p < 0.05) and supine (p < 0.01). Patients found their custom appliance was more comfortable than the titration appliance, but preferred the titration appliance to no therapy. The titration appliance may be useful in assessing oral appliance treatment efficacy. When set to 70% of maximum protrusion, the titration appliance may provide immediate, temporary therapeutic benefit.

  7. Dose titration of BAF312 attenuates the initial heart rate reducing effect in healthy subjects.

    PubMed

    Legangneux, Eric; Gardin, Anne; Johns, Donald

    2013-03-01

    Previous studies have shown transient decreases in heart rate (HR) following administration of sphingosine 1-phosphate (S1P) receptor modulators including BAF312. This study was conducted to determine whether dose titration of BAF312 reduces or eliminates these effects. Fifty-six healthy subjects were randomized 1:1:1:1 to receive BAF312 in one of two dose titration (DT) regimens (DT1 and DT2: 0.25-10 mg over 9-10 days), no titration (10 mg starting dose) or placebo. Pharmacodynamic and pharmacokinetic parameters were assessed. Neither DT1 nor DT2 resulted in clinically significant bradycardia or atrioventricular conduction effects. Both titration regimens showed a favourable difference on each of days 1-12 vs. the non-titration regimen on day 1 for HR effects (P < 0.0001). On day 1, the geometric mean ratio of the fraction from the previous day in minimum daily HR between DT1 and non-titration was 1.18 (95% confidence interval [CI] 1.13, 1.23) and 1.14 (95% CI 1.09, 1.18) for DT2 (both P < 0.05) with significant differences noted through to day 12. Non-titration HRs showed considerable separation from placebo throughout the study. There was no statistically significant reduction in HR vs. placebo on day 1 in either titration regimen. On days 3-7 subjects in DT1 and DT2 experienced minor reductions in HR vs. placebo (approximately 5 beats min⁻¹; P ≤ 0.0001). From days 9-12, HRs in both titration regimens were comparable with placebo. Both titration regimens effectively attenuated the initial bradyarrhythmia observed on day 1 of treatment with BAF312 10 mg. © 2012 Novartis Institutes for BioMedical Research (NIBIR). British Journal of Clinical Pharmacology © 2012 The British Pharmacological Society.

  8. Initial Evaluation of a Titration Appliance for Temporary Treatment of Obstructive Sleep Apnea

    PubMed Central

    Levendowski, Daniel J.; Morgan, Todd; Westbrook, Philip

    2015-01-01

    Background Custom oral appliances that adjustably advance the mandible provide superior outcomes when treating patients with moderate or severe sleep apnea. Custom appliances, however, are expensive, must be fitted by a dentist, and the likelihood of successful outcomes are difficult to predict. An inexpensive trial appliance, if proven efficacious, might be used to predict custom appliance outcomes or to provide temporary therapeutic benefit. Objective The aim of this initial study was to assess the treatment efficacy of a novel titration oral appliance with that of an optimized custom appliance. Methods Seventeen patients, treated with a custom oral appliance for at least one year, successfully completed a three-night home sleep test. The baseline obstructive sleep apnea severity was established on Night 1 with seven patients exhibiting severe, six moderate and four mild apnea/hypopnea indexes. Patients were randomly assigned to wear their custom appliance or the titration appliance on Nights 2 and 3. Results Significant reductions in the mean overall and supine apnea indexes (p < 0.05), and the overall (p < 0.01) and supine (p < 0.05) apnea/hypopnea indexes were observed for both the titration and custom appliances. The proportion of patients who exhibited at least a 50% reduction in the overall apnea index and supine apnea/hypopnea were similar for the titration and custom appliance (~60%). The custom appliance reduced the overall apnea/hypopnea index by 50% in a greater proportion of the patients compared to the titration appliance (77% vs. 53%). The titration appliance significantly reduced the degree of hypoxic exposure across sleep disordered breathing events overall (p < 0.05) and supine (p < 0.01). Patients found their custom appliance was more comfortable than the titration appliance, but preferred the titration appliance to no therapy. Conclusion The titration appliance may be useful in assessing oral appliance treatment efficacy. When set to 70% of maximum protrusion, the titration appliance may provide immediate, temporary therapeutic benefit. PMID:26523244

  9. Control of OSA during automatic positive airway pressure titration in a clinical case series: predictors and accuracy of device download data.

    PubMed

    Huang, Hsin-Chia Carol; Hillman, David R; McArdle, Nigel

    2012-09-01

    To investigate the factors associated with physiologic control of obstructive sleep apnea (OSA) during automatic positive airway pressure (APAP) titration in a clinical series. To also assess the usefulness of apnea-hypopnea index (AHI) data downloaded from the APAP device (Dev AHI). Retrospective review of a consecutive series of patients with OSA who underwent APAP titration (Autoset Spirit, ResMed, Bella Vista, New South Wales, Australia ) with simultaneous polysomnographic (PSG) monitoring in the sleep laboratory. Tertiary sleep clinic. There were 190 consecutive patients with OSA referred for APAP titration. There were 58% of patients who achieved optimal or good control of OSA (titration PSG AHI < 10, or at least 50% reduction in AHI if diagnostic AHI < 15/hr) during APAP titration. The independent predictors of titration PSG AHI were a history of cardiac disease and elevated central apnea and arousal indices during the diagnostic study. Although the median and interquartile range (IQR) AHI from the device (7.0, 3.9-11.6 events/hr) was only slightly less than the PSG AHI (7.8, 3.9-14.4 events/hr, P = 0.04) during titration, case-by-case agreement between the two measures was poor (chi-square < 0.001). In a clinical sample control of OSA during APAP titration is often poor, and close clinical follow-up is particularly needed in patients with a history of cardiac disease or with high arousal or central apnea indices on the diagnostic study. Device AHI does not reliably assess control during APAP titration, and PSG assessment may be required if clinical response to treatment is poor. The findings relate to the ResMed AutoSet device and may not apply to other devices.

  10. An RCT Investigating Patient-Driven Versus Physician-Driven Titration of BIAsp 30 in Patients with Type 2 Diabetes Uncontrolled Using NPH Insulin.

    PubMed

    Chraibi, Abdelmjid; Al-Herz, Shoorook; Nguyen, Bich Dao; Soeatmadji, Djoko W; Shinde, Anil; Lakshmivenkataraman, Balasubramanian; Assaad-Khalil, Samir H

    2017-08-01

    The aim of this study was to confirm the efficacy of patient-driven titration of BIAsp 30 in terms of glycemic control, by comparing it to physician-driven titration of BIAsp 30, in patients with type 2 diabetes in North Africa, the Middle East, and Asia. A 20-week, open-label, randomized, two-armed, parallel-group, multicenter study in Egypt, Indonesia, Morocco, Saudi Arabia, and Vietnam. Patients (n = 155) with type 2 diabetes inadequately controlled using neutral protamine Hagedorn (NPH) insulin were randomized to either patient-driven or physician-driven BIAsp 30 titration. The noninferiority of patient-driven compared to physician-driven titration with respect to the reduction in HbA1c was confirmed. The estimated mean change in HbA1c from baseline to week 20 was -1.27% in the patient-driven arm and -1.04% in the physician-driven arm, with an estimated treatment difference of -0.23% (95% confidence interval: -0.54; 0.08). After 20 weeks of treatment, the proportions of patients achieving the target of HbA1c <7.5% were similar between titration arms; the proportions of patients achieving the target of ≤6.5% were also similar. Both titration algorithms were well tolerated, and hypoglycemic episode rates were similar in both arms. Patient-driven titration of BIAsp 30 can be as effective and safe as physician-driven titration in non-Western populations. Overall, the switch from NPH insulin to BIAsp 30 was well tolerated in both titration arms and led to improved glycemic control. A limitation of the study was the relatively small number of patients recruited in each country. ClinicalTrials.gov NCT01589653. Novo Nordisk A/S, Denmark.

  11. Persistent benefits of slow titration of paroxetine in a six-month follow-up.

    PubMed

    Olgiati, Paolo; Serretti, Alessandro

    2015-09-01

    Paroxetine titration may be difficult in older individuals as they are more sensitive to side effects. The current study extends to 6 months our previously published report in which paroxetine was started at 2.5 mg/day and slowly increased by 2.5 mg on alternate days (slow titration) or rapidly titrated to target dose from 10 mg/day (standard titration) in a naturalistic setting. Here, the follow-up period was extended to 26 weeks. We performed an intent-to-treat analysis of 47 subjects from the original sample (major depressive disorder and/or generalized anxiety disorder (GAD); >60 years of age). Missing evaluations were replaced by last observations carried forward. GAD was included as a stratification factor. Patients in whom paroxetine was slowly up-titrated were more likely to remit (84.0% vs 54.5%; p = 0.028) and had lower core depression (p = 0.0015) and psychic anxiety levels (p = 0.006) after 26 weeks. Dropout rate was 20% in the slow titration group compared with 77.3% in the standard titration arm (p < 0.001). Patients with GAD accounted for all significant associations. No substantial differences were reported between slow and standard titration groups in the subsample without GAD. Despite some limitations, these findings suggest that paroxetine treatment should be started at lower doses in older depressed patients and slowly up-titrated. This strategy would allow to increase antidepressant response and the likelihood of completing treatment cycle in patients with high anxiety levels and GAD comorbidity. Copyright © 2015 John Wiley & Sons, Ltd.

  12. Optimizing Glycemic Control Through Titration of Insulin Glargine 100 U/mL: A Review of Current and Future Approaches with a Focus on Asian Populations.

    PubMed

    Deerochanawong, Chaicharn; Bajpai, Shailendra; Dwipayana, I Made Pande; Hussein, Zanariah; Mabunay, Maria Aileen; Rosales, Reynaldo; Tsai, Shih-Tzer; Tsang, Man Wo

    2017-12-01

    Various data have demonstrated inadequate glycemic control amongst Asians with type 2 diabetes mellitus (T2DM), possibly on account of suboptimal titration of basal insulin-an issue which needs to be further examined. Here we review the available global and Asia-specific data on titration of basal insulin, with a focus on the use of insulin glargine 100 U/mL (Gla-100). We also discuss clinical evidence on the efficacy and safety of titrating Gla-100, different approaches to titration, including some of the latest technological advancements, and guidance on the titration of basal insulin from international and local Asian guidelines. The authors also provide their recommendations for the initiation and titration of basal insulin for Asian populations. Discussion of the data included in this review and in relation to the authors' clinical experience with treating T2DM in Asian patients is also included. Briefly, clinical studies demonstrate the achievement of adequate glycemic control in adults with T2DM through titration of Gla-100. However, studies investigating approaches to titration, specifically in Asian populations, are lacking and need to be conducted. Given that the management of insulin therapy is a multidisciplinary team effort involving endocrinologists, primary care physicians, nurse educators, and patients, greater resources and education targeted at these groups are needed regarding the optimal titration of basal insulin. Technological advancements in the form of mobile or web-based applications for automated dose adjustment can aid different stakeholders in optimizing the dose of basal insulin, enabling a larger number of patients in Asia to reach their target glycemic goals with improved outcomes.

  13. Up-titration of allopurinol in patients with gout.

    PubMed

    Jennings, Claudine G; Mackenzie, Isla S; Flynn, Rob; Ford, Ian; Nuki, George; De Caterina, Raffaele; Riches, Philip L; Ralston, Stuart H; MacDonald, Thomas M

    2014-08-01

    European League against Rheumatism (EULAR) gout management guidelines recommend achieving a target urate level <6.0 mg/dL (<357 µmol/L). Allopurinol is the most widely used urate-lowering therapy; however, many gout patients who are prescribed allopurinol do not have urate levels optimally controlled. The objective of this analysis was to review the efficacy and tolerability of allopurinol up-titration in achieving the EULAR target levels. The Febuxostat versus Allopurinol Streamlined Trial (FAST) is an ongoing multi-centre study comparing the cardiovascular safety of febuxostat and allopurinol (target recruitment: 5706 patients). Recruited patients were already taking allopurinol and the protocol required up-titration of daily allopurinol dose, in 100 mg increments, to achieve the EULAR urate target level prior to randomisation. We reviewed pre-randomisation data from the first 400 recruited and subsequently randomised FAST patients. Of 400 patients, 144 (36%) had urate levels ≥357 µmol/L at screening and required allopurinol up-titration. Higher urate levels were significantly associated with lower allopurinol dose, male sex, increased BMI, increased alcohol intake and diuretic use. Mean fall in urate levels after a single 100-mg dose increase was 71 µmol/L. The number of up-titrations required ranged from one to five (median = 1) with 65% of patients controlled after one 100-mg up-titration. Overall, 97% of up-titrated patients achieved target urate levels with median final allopurinol dose of 300 mg daily. Side effects and complications of up-titration were minimal. Overall, 36% of FAST patients were not at target urate levels and required up-titration. Allopurinol up-titration was effective in achieving urate target levels and was generally well tolerated by patients. Copyright © 2014 Elsevier Inc. All rights reserved.

  14. Parametric changes in response equilibrium during an intra-cranial self stimulation (ICSS) task: can reward value be assessed independently of absolute threshold?

    PubMed

    Easterling, K W; Holtzman, S G

    1997-01-01

    Traditional ICSS methodologies have attempted to evaluate changes in the rewarding value of brain stimulation by assessing the lowest value of the stimulation that will support responding. However, orderly changes in suprathreshold indicants of hedonic magnitude such as titration point have been shown. In the present experiments, rats were trained to respond on two ICSS autotitration schedules in which every response on one lever produced stimulation of the medial forebrain bundle, and every Xth response decreased either the stimulation current or the stimulation frequency. At any time, a response on a second "reset" lever restored the stimulation current or frequency available on the stimulation lever to its starting level and operationally defined changes in "reward value". In order to study this titration point measure, two response requirements (responses/stepdown; step size) and two stimulation parameters (initial stimulation level; train duration) were systematically varied. Under both current and frequency titration schedules, data indicated that response rate and titration point remained stable over repeated trials and multiple testing days--parameters being constant. Across all conditions, compared to the frequency titration schedule, subjects responding under the current titration schedule showed significantly higher titration points and lower rates of responding. Indicating the independence of rate and titration point data, parametric manipulations did not affect titration point and rate data concurrently. Results support the conclusion that titration point is a relative measure of "reward value" that is generally independent of response rate, but that is affected by manipulations that alter the amount of stimulation available between "resets". Additional work is needed in order to determine the relationship between the magnitude of stimulation needed to maintain minimal responding and that needed to maintain response equilibrium in an autotitration task.

  15. Viscoelastic Tamponade Applied to the Ocular Surface for Enhanced Control of Gaseous Egress From the Anterior Chamber During Final Bubble Titration in DMEK Surgery: The "Polite" Burp.

    PubMed

    Sales, Christopher S; Fernandez, Ana Alzaga; Anwar, Zane

    2018-07-01

    To present a novel technique for enhancing the surgeon's control over the volume of air or gas that is "burped" from the anterior chamber during final bubble and intraocular pressure (IOP) titration in Descemet membrane endothelial keratoplasty. After ascertaining that the intracameral bubble is either too large and/or has rendered IOP too high, a bead of ophthalmic viscoelastic is applied to the ocular surface over a paracentesis incision, which is then depressed in the usual fashion to burp gas from the anterior chamber. The weight and viscosity of the viscoelastic create a tamponade that slows the egress of gas from the anterior chamber, thereby making it more controllable. If the bubble size or IOP needs to be reduced at the conclusion of the Descemet membrane endothelial keratoplasty procedure, application of ophthalmic viscoelastic over the paracentesis can enhance the surgeon's control over the volume of gas burped from the anterior chamber, thereby reducing the tendency to swing between a bubble that is too large or too small.

  16. Structural changes in calcium-binding allergens: use of circular dichroism to study binding characteristics.

    PubMed

    Hebenstreit, D; Ferreira, F

    2005-09-01

    Several studies showed that calcium-binding proteins have a fixed place in the spectrum of allergenic substances. Often the binding of a calcium ion induces conformational changes and affects immunoglobulin E-binding to the allergen. Hence, the quantitative characterization of the binding to calcium is of importance to understand both the biologic and allergenic activity of these proteins. In the present study we describe a procedure for determining the stoichiometry and dissociation constant (K(D)) of calcium-binding allergens using circular dichroism (CD) techniques. For the experiments, we used recombinant Bet v 4, a two EF-hand allergen from birch pollen. Solutions of Bet v 4 were titrated with calcium and the change in molar ellipticity at 222 nm was monitored with a CD spectropolarimeter. The determination of the binding stoichiometry as well as of the K(D) for one EF-hand (4 microM) demonstrated the applicability of the method. CD-monitored calcium-titration of protein solutions represents a fast and easy method for determining the binding characteristics of calcium-binding allergens.

  17. Determination of Carbonyl Functional Groups in Bio-oils by Potentiometric Titration: The Faix Method

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Black, Stuart; Ferrell, Jack R.

    We know that carbonyl compounds, present in bio-oils, are responsible for bio-oil property changes upon storage and during upgrading. Specifically, carbonyls cause an increase in viscosity (often referred to as 'aging') during storage of bio-oils. As such, carbonyl content has previously been used as a method of tracking bio-oil aging and condensation reactions with less variability than viscosity measurements. In addition, carbonyls are also responsible for coke formation in bio-oil upgrading processes. Given the importance of carbonyls in bio-oils, accurate analytical methods for their quantification are very important for the bio-oil community. Potentiometric titration methods based on carbonyl oximation havemore » long been used for the determination of carbonyl content in pyrolysis bio-oils. Here, we present a modification of the traditional carbonyl oximation procedures that results in less reaction time, smaller sample size, higher precision, and more accurate carbonyl determinations. And while traditional carbonyl oximation methods occur at room temperature, the Faix method presented here occurs at an elevated temperature of 80 degrees C.« less

  18. [Determination of total protein content in soya-bean milk via visual moving reaction boundary titration].

    PubMed

    Guo, Chengye; Wang, Houyu; Zhang, Lei; Fan, Liuyin; Cao, Chengxi

    2013-11-01

    A visual, rapid and accurate moving reaction boundary titration (MRBT) method was used for the determination of the total protein in soya-bean milk. During the process, moving reaction boundary (MRB) was formed by hydroxyl ions in the catholyte and soya-bean milk proteins immobilized in polyacrylamide gel (PAG), and an acid-base indicator was used to denote the boundary motion. The velocity of MRB has a relationship with protein concentration, which was used to obtain a standard curve. By paired t-test, there was no significant difference of the protein content between MRBT and Kjeldahl method at 95% confidence interval. The procedure of MRBT method required about 10 min, and it had linearity in the range of 2.0-14.0 g/L, low limit of detection (0.05 g/L), good precision (RSD of intra-day < 1.90% and inter-day < 4.39%), and high recoveries (97.41%-99.91%). In addition, non-protein nitrogen (NPN) such as melamine added into the soya-bean milk had weak influence on MRBT results.

  19. Determination of Carbonyl Functional Groups in Bio-oils by Potentiometric Titration: The Faix Method

    DOE PAGES

    Black, Stuart; Ferrell, Jack R.

    2017-02-07

    We know that carbonyl compounds, present in bio-oils, are responsible for bio-oil property changes upon storage and during upgrading. Specifically, carbonyls cause an increase in viscosity (often referred to as 'aging') during storage of bio-oils. As such, carbonyl content has previously been used as a method of tracking bio-oil aging and condensation reactions with less variability than viscosity measurements. In addition, carbonyls are also responsible for coke formation in bio-oil upgrading processes. Given the importance of carbonyls in bio-oils, accurate analytical methods for their quantification are very important for the bio-oil community. Potentiometric titration methods based on carbonyl oximation havemore » long been used for the determination of carbonyl content in pyrolysis bio-oils. Here, we present a modification of the traditional carbonyl oximation procedures that results in less reaction time, smaller sample size, higher precision, and more accurate carbonyl determinations. And while traditional carbonyl oximation methods occur at room temperature, the Faix method presented here occurs at an elevated temperature of 80 degrees C.« less

  20. The predictive value of drug-induced sleep endoscopy for CPAP titration in OSA patients.

    PubMed

    Lan, Ming-Chin; Hsu, Yen-Bin; Lan, Ming-Ying; Huang, Yun-Chen; Kao, Ming-Chang; Huang, Tung-Tsun; Chiu, Tsan-Jen; Yang, Mei-Chen

    2017-12-15

    The aim of this study was to identify possible upper airway obstructions causing a higher continuous positive airway pressure (CPAP) titration level, utilizing drug-induced sleep endoscopy (DISE). A total of 76 patients with obstructive sleep apnea (OSA) underwent CPAP titration and DISE. DISE findings were recorded using the VOTE classification system. Polysomnographic (PSG) data, anthropometric variables, and patterns of airway collapse during DISE were analyzed with CPAP titration levels. A significant association was found between the CPAP titration level and BMI, oxygen desaturation index (ODI), apnea-hypopnea index (AHI), and neck circumference (NC) (P < 0.001, P < 0.001, P < 0.001, and P < 0.001, respectively, by Spearman correlation). Patients with concentric collapse of the velum or lateral oropharyngeal collapse were associated with a significantly higher CPAP titration level (P < 0.001 and P = 0.043, respectively, by nonparametric Mann-Whitney U test; P < 0.001 and P = 0.004, respectively, by Spearman correlation). No significant association was found between the CPAP titration level and any other collapse at the tongue base or epiglottis. By analyzing PSG data, anthropometric variables, and DISE results with CPAP titration levels, we can better understand possible mechanisms resulting in a higher CPAP titration level. We believe that the role of DISE can be expanded as a tool to identify the possible anatomical structures that may be corrected by oral appliance therapy or surgical intervention to improve CPAP compliance.

  1. Economic benefit of back titration in the treatment of hypertension in Jos, Nigeria.

    PubMed

    Okeahialam, Basil N; Adeniyi, Michael A

    2017-01-01

    Treatment of hypertension is expensive and cost is one of the reasons for inadequate blood pressure control. Where there are no social cost cushions, the burden is borne by patients. With pervasive poverty and inadequate control, complications are unchecked. Back titration in appropriate circumstances should, therefore, translate to economic benefit. This is an attempt to compute, in economic terms, the benefit of back titration. Thirty-nine patients who entered an antihypertensive back titration program for 12 months and who had been earlier reported on, form the subject of this study. A survey of the cost of antihypertensives in pharmacy outlets in Jos, Nigeria was undertaken. Regimens of antihypertensives that patients were on at the onset and end of the 12 months of back titration were costed in Nigerian currency and compared. Back titration translated to economic benefit in all patients with a cost reduction varying from 2.3% to 100%. This reflected in reduction in mean daily cost of treatment of N107.09-N54.61. The benefit of antihypertensive back titration apart from psychological relief of lower pill burden and side effect profile is in pharmacoeconomics. This permits greater adherence and prevents morbi-mortality consequences of hypertension. In this study, back titration over 12 months translated to average cost reduction of >50%, making treatment more affordable. In appropriate circumstances, back titration of antihypertensives results in economic relief for patients. This should improve adherence, reduce morbi-mortality and is recommended for wider application.

  2. Students' integration of multiple representations in a titration experiment

    NASA Astrophysics Data System (ADS)

    Kunze, Nicole M.

    A complete understanding of a chemical concept is dependent upon a student's ability to understand the microscopic or particulate nature of the phenomenon and integrate the microscopic, symbolic, and macroscopic representations of the phenomenon. Acid-base chemistry is a general chemistry topic requiring students to understand the topics of chemical reactions, solutions, and equilibrium presented earlier in the course. In this study, twenty-five student volunteers from a second semester general chemistry course completed two interviews. The first interview was completed prior to any classroom instruction on acids and bases. The second interview took place after classroom instruction, a prelab activity consisting of a titration calculation worksheet, a titration computer simulation, or a microscopic level animation of a titration, and two microcomputer-based laboratory (MBL) titration experiments. During the interviews, participants were asked to define and describe acid-base concepts and in the second interview they also drew the microscopic representations of four stages in an acid-base titration. An analysis of the data showed that participants had integrated the three representations of an acid-base titration to varying degrees. While some participants showed complete understanding of acids, bases, titrations, and solution chemistry, other participants showed several alternative conceptions concerning strong acid and base dissociation, the formation of titration products, and the dissociation of soluble salts. Before instruction, participants' definitions of acid, base, and pH were brief and consisted of descriptive terms. After instruction, the definitions were more scientific and reflected the definitions presented during classroom instruction.

  3. Differential Binding Models for Direct and Reverse Isothermal Titration Calorimetry.

    PubMed

    Herrera, Isaac; Winnik, Mitchell A

    2016-03-10

    Isothermal titration calorimetry (ITC) is a technique to measure the stoichiometry and thermodynamics from binding experiments. Identifying an appropriate mathematical model to evaluate titration curves of receptors with multiple sites is challenging, particularly when the stoichiometry or binding mechanism is not available. In a recent theoretical study, we presented a differential binding model (DBM) to study calorimetry titrations independently of the interaction among the binding sites (Herrera, I.; Winnik, M. A. J. Phys. Chem. B 2013, 117, 8659-8672). Here, we build upon our DBM and show its practical application to evaluate calorimetry titrations of receptors with multiple sites independently of the titration direction. Specifically, we present a set of ordinary differential equations (ODEs) with the general form d[S]/dV that can be integrated numerically to calculate the equilibrium concentrations of free and bound species S at every injection step and, subsequently, to evaluate the volume-normalized heat signal (δQ(V) = δq/dV) of direct and reverse calorimetry titrations. Additionally, we identify factors that influence the shape of the titration curve and can be used to optimize the initial concentrations of titrant and analyte. We demonstrate the flexibility of our updated DBM by applying these differentials and a global regression analysis to direct and reverse calorimetric titrations of gadolinium ions with multidentate ligands of increasing denticity, namely, diglycolic acid (DGA), citric acid (CIT), and nitrilotriacetic acid (NTA), and use statistical tests to validate the stoichiometries for the metal-ligand pairs studied.

  4. Documentation for the machine-readable version of photometric data for nearby stars

    NASA Technical Reports Server (NTRS)

    Warren, W. H., Jr.

    1982-01-01

    A computer list of all photometric systems (of those considered), in which each star was measured is provided. The file is a subset of a much larger and more comprehensive compilation, which lists all measured photoelectric photometric systems for any star that has been measured in at least one photoelectric system. In addition to the photometric system identifications, cross identifications to the Henry Draper and Durchmusterung catalogs and apparent visual magnitudes are included.

  5. Photo-z-SQL: Photometric redshift estimation framework

    NASA Astrophysics Data System (ADS)

    Beck, Róbert; Dobos, László; Budavári, Tamás; Szalay, Alexander S.; Csabai, István

    2017-04-01

    Photo-z-SQL is a flexible template-based photometric redshift estimation framework that can be seamlessly integrated into a SQL database (or DB) server and executed on demand in SQL. The DB integration eliminates the need to move large photometric datasets outside a database for redshift estimation, and uses the computational capabilities of DB hardware. Photo-z-SQL performs both maximum likelihood and Bayesian estimation and handles inputs of variable photometric filter sets and corresponding broad-band magnitudes.

  6. New aspects relating to the behaviour of composites and adhesives in space

    NASA Technical Reports Server (NTRS)

    Carpenter, A.

    1991-01-01

    Some of the specialized testing procedures performed at the JPL Molecular Contamination Investigation Facility for the WideField Planetary Camera II (WFPC II) program for the screening of polymeric materials for outgassing properties are described. For WFPC II, a science performance goal of 1-percent photometric accuracy at 1470 A over an extended time (at least 30 days) has been established. Utilization of the newest technology using CCD detectors poses even more stringent requirements. Test results are presented, and data reduction and modeling techniques are discussed.

  7. The determination of antipyrine elimination in saliva by liquid chromatography.

    PubMed

    Gartzke, J; Jäger, H

    1991-01-01

    A simple, fast and reliable liquid chromatographic method for the determination of antipyrine in saliva is described. The elimination of antipyrine is a good indicator for general evaluation of the liver function for dispositional purposes for example in occupational and environmental medicine. The described LC method was compared with a more extensive photometric procedure. The results obtained from both methods show very good correlation. Only one measurement is necessary to determine the antipyrine clearance. Furthermore the antipyrine dosage can be minimized, because of the sensitivity of the HPLC-method.

  8. Full toroidal imaging of non-axisymmetric plasma material interaction in the National Spherical Torus Experiment divertor.

    PubMed

    Scotti, Filippo; Roquemore, A L; Soukhanovskii, V A

    2012-10-01

    A pair of two dimensional fast cameras with a wide angle view (allowing a full radial and toroidal coverage of the lower divertor) was installed in the National Spherical Torus Experiment in order to monitor non-axisymmetric effects. A custom polar remapping procedure and an absolute photometric calibration enabled the easier visualization and quantitative analysis of non-axisymmetric plasma material interaction (e.g., strike point splitting due to application of 3D fields and effects of toroidally asymmetric plasma facing components).

  9. Concentration determination of methyl magnesium chloride and other Grignard reagents by potentiometric titration with in-line characterization of reaction species by FTIR spectroscopy.

    PubMed

    Chen, Yadan; Wang, Tao; Helmy, Roy; Zhou, George X; LoBrutto, Rosario

    2002-07-01

    A potentiometric titration method for methyl magnesium chloride and other Grignard reagents based on the reaction with 2-butanol in THF has been developed and validated. The method employs a commercially available platinum electrode, using an electrolyte compatible with non-aqueous solvents. Well-defined titration curves were obtained, along with excellent method precision. The endpoint was precisely determined based on the first derivative of the titration curve. Different solvents such as THF, diethyl ether and methylene chloride provided similar results with regard to sharpness of the endpoint and method precision. The method was applied to a wide array of Grignard reagents including methyl magnesium bromide, ethyl magnesium chloride, propyl magnesium chloride, vinyl magnesium chloride, phenyl magnesium chloride, and benzyl magnesium chloride with similar precision and accuracy. Application of in-line FTIR was demonstrated for in situ monitoring of the titration reaction, allowing characterization of the reaction species. An authentic spectrum of the MeMgCl-THF complex was obtained using spectral subtraction and the vibrational absorbance bands were identified. FTIR also provided an alternative for detecting the titration endpoint, and the titration results so obtained, provided a cross-validation of the accuracy of the potentiometric titration.

  10. Titration in the treatment of the more troubled patient.

    PubMed

    Winer, J A; Ornstein, E D

    2001-01-01

    This article defines and discusses a modification of technique recommended by the authors in the psychoanalytic treatment of more troubled patients--a modification they call titration. Titration is defined as a conscious decision by the analyst to increase or decrease assistance (or gratification) gradually, in order to facilitate the analytic process. The authors emphasize the complexity of decisions in treatment by focusing on the decision-making processes that titration requires. Guidelines and a case vignette are presented. The authors conclude by considering some of the politics involved in the introduction of technique modifications, the salience of the titration concept, and directions for further exploration.

  11. Leveraging 3D-HST Grism Redshifts to Quantify Photometric Redshift Performance

    NASA Astrophysics Data System (ADS)

    Bezanson, Rachel; Wake, David A.; Brammer, Gabriel B.; van Dokkum, Pieter G.; Franx, Marijn; Labbé, Ivo; Leja, Joel; Momcheva, Ivelina G.; Nelson, Erica J.; Quadri, Ryan F.; Skelton, Rosalind E.; Weiner, Benjamin J.; Whitaker, Katherine E.

    2016-05-01

    We present a study of photometric redshift accuracy in the 3D-HST photometric catalogs, using 3D-HST grism redshifts to quantify and dissect trends in redshift accuracy for galaxies brighter than JH IR > 24 with an unprecedented and representative high-redshift galaxy sample. We find an average scatter of 0.0197 ± 0.0003(1 + z) in the Skelton et al. photometric redshifts. Photometric redshift accuracy decreases with magnitude and redshift, but does not vary monotonically with color or stellar mass. The 1σ scatter lies between 0.01 and 0.03 (1 + z) for galaxies of all masses and colors below z < 2.5 (for JH IR < 24), with the exception of a population of very red (U - V > 2), dusty star-forming galaxies for which the scatter increases to ˜0.1 (1 + z). We find that photometric redshifts depend significantly on galaxy size; the largest galaxies at fixed magnitude have photo-zs with up to ˜30% more scatter and ˜5 times the outlier rate. Although the overall photometric redshift accuracy for quiescent galaxies is better than that for star-forming galaxies, scatter depends more strongly on magnitude and redshift than on galaxy type. We verify these trends using the redshift distributions of close pairs and extend the analysis to fainter objects, where photometric redshift errors further increase to ˜0.046 (1 + z) at {H}F160W=26. We demonstrate that photometric redshift accuracy is strongly filter dependent and quantify the contribution of multiple filter combinations. We evaluate the widths of redshift probability distribution functions and find that error estimates are underestimated by a factor of ˜1.1-1.6, but that uniformly broadening the distribution does not adequately account for fitting outliers. Finally, we suggest possible applications of these data in planning for current and future surveys and simulate photometric redshift performance in the Large Synoptic Survey Telescope, Dark Energy Survey (DES), and combined DES and Vista Hemisphere surveys.

  12. Process monitored spectrophotometric titration coupled with chemometrics for simultaneous determination of mixtures of weak acids.

    PubMed

    Liao, Lifu; Yang, Jing; Yuan, Jintao

    2007-05-15

    A new spectrophotometric titration method coupled with chemometrics for the simultaneous determination of mixtures of weak acids has been developed. In this method, the titrant is a mixture of sodium hydroxide and an acid-base indicator, and the indicator is used to monitor the titration process. In a process of titration, both the added volume of titrant and the solution acidity at each titration point can be obtained simultaneously from an absorption spectrum by least square algorithm, and then the concentration of each component in the mixture can be obtained from the titration curves by principal component regression. The method only needs the information of absorbance spectra to obtain the analytical results, and is free of volumetric measurements. The analyses are independent of titration end point and do not need the accurate values of dissociation constants of the indicator and the acids. The method has been applied to the simultaneous determination of the mixtures of benzoic acid and salicylic acid, and the mixtures of phenol, o-chlorophenol and p-chlorophenol with satisfactory results.

  13. The many flavours of photometric redshifts

    NASA Astrophysics Data System (ADS)

    Salvato, Mara; Ilbert, Olivier; Hoyle, Ben

    2018-06-01

    Since more than 70 years ago, the colours of galaxies derived from flux measurements at different wavelengths have been used to estimate their cosmological distances. Such distance measurements, called photometric redshifts, are necessary for many scientific projects, ranging from investigations of the formation and evolution of galaxies and active galactic nuclei to precision cosmology. The primary benefit of photometric redshifts is that distance estimates can be obtained relatively cheaply for all sources detected in photometric images. The drawback is that these cheap estimates have low precision compared with resource-expensive spectroscopic ones. The methodology for estimating redshifts has been through several revolutions in recent decades, triggered by increasingly stringent requirements on the photometric redshift accuracy. Here, we review the various techniques for obtaining photometric redshifts, from template-fitting to machine learning and hybrid schemes. We also describe state-of-the-art results on current extragalactic samples and explain how survey strategy choices affect redshift accuracy. We close with a description of the photometric redshift efforts planned for upcoming wide-field surveys, which will collect data on billions of galaxies, aiming to investigate, among other matters, the stellar mass assembly and the nature of dark energy.

  14. A Comparison of the OSHA Modified NIOSH Physical and Chemical Analytical Method (P and CAM) 304 and the Dust Trak Photometric Aerosol Sampler for 0-Chlorobenzylidine Malonitrile

    DTIC Science & Technology

    2013-04-02

    photometric particle counting instrument, DustTrak, to the established OSHA modified NIOSH P&CAM 304 method to determine correlation between the two...study compared the non-specific, rapid photometric particle counting instrument, DustTrak, to the established OSHA modified NIOSH P&CAM 304 method...mask confidence training (27) . This study will compare a direct reading, non-specific photometric particle count instrument (DustTrak TSI Model

  15. An Olfactory Indicator for Acid-Base Titrations.

    ERIC Educational Resources Information Center

    Flair, Mark N.; Setzer, William N.

    1990-01-01

    The use of an olfactory acid-base indicator in titrations for visually impaired students is discussed. Potential olfactory indicators include eugenol, thymol, vanillin, and thiophenol. Titrations performed with each indicator with eugenol proved to be successful. (KR)

  16. On-Board Monitoring of Engine Oil

    DTIC Science & Technology

    2011-04-01

    Viscosity of Transparent and Opaque Liquids at 40°C Infracal Soot Meter Karl Fischer Titration ASTM D 664 Standard Test Method for Acid Number of... methods involve potentiometric and colorimetric titrations, respectively. For both tests, a titration solvent is prepared and added to the oil. The...ASTM D 2896 and ASTM D 4739 [17]. Both methods involve potentiometric titrations. ASTM D 2896 uses a stronger acid and more polar solvent than ASTM D

  17. Integration and global analysis of isothermal titration calorimetry data for studying macromolecular interactions.

    PubMed

    Brautigam, Chad A; Zhao, Huaying; Vargas, Carolyn; Keller, Sandro; Schuck, Peter

    2016-05-01

    Isothermal titration calorimetry (ITC) is a powerful and widely used method to measure the energetics of macromolecular interactions by recording a thermogram of differential heating power during a titration. However, traditional ITC analysis is limited by stochastic thermogram noise and by the limited information content of a single titration experiment. Here we present a protocol for bias-free thermogram integration based on automated shape analysis of the injection peaks, followed by combination of isotherms from different calorimetric titration experiments into a global analysis, statistical analysis of binding parameters and graphical presentation of the results. This is performed using the integrated public-domain software packages NITPIC, SEDPHAT and GUSSI. The recently developed low-noise thermogram integration approach and global analysis allow for more precise parameter estimates and more reliable quantification of multisite and multicomponent cooperative and competitive interactions. Titration experiments typically take 1-2.5 h each, and global analysis usually takes 10-20 min.

  18. Efficacy and Tolerability of Two Different Kinds of Titration of Paroxetine Hydrocloride Solution: an Observational Study.

    PubMed

    Ielmini, Marta; Poloni, Nicola; Caselli, Ivano; Bianchi, Lucia; Diurni, Marcello; Vender, Simone; Callegari, Camilla

    2018-03-13

    Depressive disorders are expected to be the second highest cause of morbidity in the world until few years. Moreover, patients with depression frequently show many side effects and low compliance to therapy. To find a more tolerated and more efficacy therapy is a growing need. This observational study investigates the efficacy, safety and tolerability of paroxetine hydrochloride comparing slow versus standard titration in a population affected by Depressive Disoders (according to DSM 5). 186 outpatients were assessed throught the following scales: Hamilton Depression Rating Scale (HDRS) for depression and World Health Organization Quality of Life Scale Bref for the perceived quality of life (WHOQOL BREF). Treatment-emerged Adverse Events (TEAEs) were recorded throught self-reports. Statystical analysys was performed by GraphPad Prism Version 5.1. The efficacy of paroxetine was confirmed in both titrations by the number of clinical remitters (HDRS ≤ 7 at 12 weeks for 53% of the standard titration group and 58% of the slow titration group), without differences. About safety and tolerability there were more frequent TEAEs among the standard titration group (p < 0.01). Comparing WHOQOL BREF between the two groups at the recruitment and at the twelth week emerged a statistically significant difference (p = 0.003), with highest scores reached in slow titration group. Although the short observation period is an evident limit, this study is consistent to the literature about the efficacy of both titrations of paroxetine to improve depression and shows promising results about the increased tolerability of paroxetine slow titration.

  19. Interagency comparison of iodometric methods for ozone determination

    NASA Technical Reports Server (NTRS)

    Demore, W. B.; Romanovsky, J. C.; Feldstein, M.; Mueller, P. K.; Hamming, W. J.

    1976-01-01

    The California Air Resources Board appointed an Oxidant Calibration Committee for the purpose of evaluating the accuracy of the different agency calibration procedures. The committee chose UV absorption photometry as the reference method for ozone measurement. Interagency comparisons of the various iodometric methods were conducted relative to the ultraviolet standard. The tests included versions of the iodometric methods as employed by the Air Resources Board, the Los Angeles Air Pollution Control District, and the EPA. An alternative candidate reference method for ozone measurement, gas phase titration, was also included in the test series.

  20. Tunable diode laser measurements of HO2NO2 absorption coefficients near 12.5 microns

    NASA Technical Reports Server (NTRS)

    May, R. D.; Molina, L. T.; Webster, C. R.

    1988-01-01

    A tunable diode laser spectrometer has been used to measure absorption coefficients of peroxynitric acid (HO2NO2) near the 803/cm Q branch. HO2NO2 concentrations in a low-pressure flowing gas mixture were determined from chemical titration procedures and UV absorption spectroscopy. The diode laser measured absorption coefficients, at a spectral resolution of better than 0.001/cm, are about 10 percent larger than previous Fourier transform infrared measurements made at a spectral resolution of 0.06/cm.

  1. Synthesis of Side Chain Liquid Crystal Polymers by Living Ring Opening Metathesis Polymerization. 3. Influence of Molecular Weight, Interconnecting Unit and Substituent on the Mesomorphic behavior of Polymers with Laterally Attached Mesogens

    DTIC Science & Technology

    1992-04-08

    polymethylsiloxanes, 6 -7 polyacrylates ,2,4,5 polymethacrylates, 1 ,3 and polychloroacrylates, 5 exhibit only nematic mesophases regardless of the...corresponding carboxyl chloride. Potassium bicyclo[2.2.1]hept-2-ene-5- carboxylate was prepared by titrating a methanolic solution of the carboxylic acid...Esterification of the Corresponding Benzyl Bromides. Monomers 1I-n were prepared in 47-88% yield using the following procedure. A mixture of potassium bicyclo

  2. Sedation and analgesia in gastrointestinal endoscopy: What’s new?

    PubMed Central

    Fanti, Lorella; Testoni, Pier Alberto

    2010-01-01

    Various types of sedation and analgesia technique have been used during gastrointestinal endoscopy procedures. The best methods for analgesia and sedation during gastrointestinal endoscopy are still debated. Providing an adequate regimen of sedation/analgesia might be considered an art, influencing several aspects of endoscopic procedures: the quality of the examination, the patient’s cooperation and the patient’s and physician’s satisfaction with the sedation. The properties of a model sedative agent for endoscopy would include rapid onset and offset of action, analgesic and anxiolytic effects, ease of titration to desired level of sedation, rapid recovery and an excellent safety profile. Therefore there is an impulse for development of new approaches to endoscopic sedation. This article provides an update on the methods of sedation today available and future directions in endoscopic sedation. PMID:20503443

  3. Semi-supervised learning for photometric supernova classification

    NASA Astrophysics Data System (ADS)

    Richards, Joseph W.; Homrighausen, Darren; Freeman, Peter E.; Schafer, Chad M.; Poznanski, Dovi

    2012-01-01

    We present a semi-supervised method for photometric supernova typing. Our approach is to first use the non-linear dimension reduction technique diffusion map to detect structure in a data base of supernova light curves and subsequently employ random forest classification on a spectroscopically confirmed training set to learn a model that can predict the type of each newly observed supernova. We demonstrate that this is an effective method for supernova typing. As supernova numbers increase, our semi-supervised method efficiently utilizes this information to improve classification, a property not enjoyed by template-based methods. Applied to supernova data simulated by Kessler et al. to mimic those of the Dark Energy Survey, our methods achieve (cross-validated) 95 per cent Type Ia purity and 87 per cent Type Ia efficiency on the spectroscopic sample, but only 50 per cent Type Ia purity and 50 per cent efficiency on the photometric sample due to their spectroscopic follow-up strategy. To improve the performance on the photometric sample, we search for better spectroscopic follow-up procedures by studying the sensitivity of our machine-learned supernova classification on the specific strategy used to obtain training sets. With a fixed amount of spectroscopic follow-up time, we find that, despite collecting data on a smaller number of supernovae, deeper magnitude-limited spectroscopic surveys are better for producing training sets. For supernova Ia (II-P) typing, we obtain a 44 per cent (1 per cent) increase in purity to 72 per cent (87 per cent) and 30 per cent (162 per cent) increase in efficiency to 65 per cent (84 per cent) of the sample using a 25th (24.5th) magnitude-limited survey instead of the shallower spectroscopic sample used in the original simulations. When redshift information is available, we incorporate it into our analysis using a novel method of altering the diffusion map representation of the supernovae. Incorporating host redshifts leads to a 5 per cent improvement in Type Ia purity and 13 per cent improvement in Type Ia efficiency. A web service for the supernova classification method used in this paper can be found at .

  4. Titration Calorimetry Standards and the Precision of Isothermal Titration Calorimetry Data

    PubMed Central

    Baranauskienė, Lina; Petrikaitė, Vilma; Matulienė, Jurgita; Matulis, Daumantas

    2009-01-01

    Current Isothermal Titration Calorimetry (ITC) data in the literature have relatively high errors in the measured enthalpies of protein-ligand binding reactions. There is a need for universal validation standards for titration calorimeters. Several inorganic salt co-precipitation and buffer protonation reactions have been suggested as possible enthalpy standards. The performances of several commercial calorimeters, including the VP-ITC, ITC200, and Nano ITC-III, were validated using these suggested standard reactions. PMID:19582227

  5. Benefit of slow titration of paroxetine to treat depression in the elderly.

    PubMed

    Olgiati, Paolo; Bajo, Emanuele; Serretti, Alessandro

    2014-11-01

    Paroxetine is commonly used to treat depression in the elderly; however, titration issues have been raised. Rapid titration may lead to increased anxiety and early dropout. The aim of this cost-utility analysis was to compare the potential benefit of standard (10 mg the first day) versus slow titration (2.5 mg gradually increased). Clinical analysis was based on a naturalistic trial integrated with a decision-analytic model representing second treatments for those who initially did not respond and for dropout cases. Treatment setting was a public outpatient center for mental disorders in Italy. Service use data were estimated from best practice guidelines, whereas costs (Euros; 2012) were retrieved from Italian official sources. Slow titration approach produced 0.031 more quality-adjusted life years (remission rate: 57% vs 44% in standard titration group) at an incremental cost of €5.53 (generic paroxetine) and €54.54 (brand paroxetine syrup). Incremental cost-effectiveness ratio (ICER) values were €159 and €1768, respectively, in favor of slow titration approach. Cost-effectiveness threshold, defined as ICER < 1 GDP per capita according to World Health Organization criteria, is about €25 000 in Italy. Our results are consistent with a superiority of slow titration of paroxetine in older depressed patients. However, these findings, in part based on simulated data, need to be replicated in clinical trials. Copyright © 2014 John Wiley & Sons, Ltd.

  6. 21 CFR 862.2160 - Discrete photometric chemistry analyzer for clinical use.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Discrete photometric chemistry analyzer for... AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CLINICAL CHEMISTRY AND CLINICAL TOXICOLOGY DEVICES Clinical Laboratory Instruments § 862.2160 Discrete photometric chemistry analyzer for clinical use. (a...

  7. 21 CFR 862.2160 - Discrete photometric chemistry analyzer for clinical use.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Discrete photometric chemistry analyzer for... AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CLINICAL CHEMISTRY AND CLINICAL TOXICOLOGY DEVICES Clinical Laboratory Instruments § 862.2160 Discrete photometric chemistry analyzer for clinical use. (a...

  8. 21 CFR 862.2160 - Discrete photometric chemistry analyzer for clinical use.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Discrete photometric chemistry analyzer for... AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CLINICAL CHEMISTRY AND CLINICAL TOXICOLOGY DEVICES Clinical Laboratory Instruments § 862.2160 Discrete photometric chemistry analyzer for clinical use. (a...

  9. 21 CFR 862.2160 - Discrete photometric chemistry analyzer for clinical use.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Discrete photometric chemistry analyzer for... AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CLINICAL CHEMISTRY AND CLINICAL TOXICOLOGY DEVICES Clinical Laboratory Instruments § 862.2160 Discrete photometric chemistry analyzer for clinical use. (a...

  10. Control of OSA During Automatic Positive Airway Pressure Titration in a Clinical Case Series: Predictors and Accuracy of Device Download Data

    PubMed Central

    Huang, Hsin-Chia Carol; Hillman, David R.; McArdle, Nigel

    2012-01-01

    Study Objectives: To investigate the factors associated with physiologic control of obstructive sleep apnea (OSA) during automatic positive airway pressure (APAP) titration in a clinical series. To also assess the usefulness of apnea-hypopnea index (AHI) data downloaded from the APAP device (Dev AHI). Design: Retrospective review of a consecutive series of patients with OSA who underwent APAP titration (Autoset Spirit, ResMed, Bella Vista, New South Wales, Australia ) with simultaneous polysomnographic (PSG) monitoring in the sleep laboratory. Setting: Tertiary sleep clinic. Participants: There were 190 consecutive patients with OSA referred for APAP titration. Measurements and Results: There were 58% of patients who achieved optimal or good control of OSA (titration PSG AHI < 10, or at least 50% reduction in AHI if diagnostic AHI < 15/hr) during APAP titration. The independent predictors of titration PSG AHI were a history of cardiac disease and elevated central apnea and arousal indices during the diagnostic study. Although the median and interquartile range (IQR) AHI from the device (7.0, 3.9-11.6 events/hr) was only slightly less than the PSG AHI (7.8, 3.9-14.4 events/hr, P = 0.04) during titration, case-by-case agreement between the two measures was poor (chi-square < 0.001). Conclusion: In a clinical sample control of OSA during APAP titration is often poor, and close clinical follow-up is particularly needed in patients with a history of cardiac disease or with high arousal or central apnea indices on the diagnostic study. Device AHI does not reliably assess control during APAP titration, and PSG assessment may be required if clinical response to treatment is poor. The findings relate to the ResMed AutoSet device and may not apply to other devices. Citation: Huang HCC; Hillman DR; McArdle N. Control of OSA during automatic positive airway pressure titration in a clinical case series: predictors and accuracy of device download data. SLEEP 2012;35(9):1277–1283. PMID:22942506

  11. A model for oxygen conservation associated with titration during pediatric oxygen therapy.

    PubMed

    Wu, Grace; Wollen, Alec; Himley, Stephen; Austin, Glenn; Delarosa, Jaclyn; Izadnegahdar, Rasa; Ginsburg, Amy Sarah; Zehrung, Darin

    2017-01-01

    Continuous oxygen treatment is essential for managing children with hypoxemia, but access to oxygen in low-resource countries remains problematic. Given the high burden of pneumonia in these countries and the fact that flow can be gradually reduced as therapy progresses, oxygen conservation through routine titration warrants exploration. To determine the amount of oxygen saved via titration during oxygen therapy for children with hypoxemic pneumonia. Based on published clinical data, we developed a model of oxygen flow rates needed to manage hypoxemia, assuming recommended flow rate at start of therapy, and comparing total oxygen used with routine titration every 3 minutes or once every 24 hours versus no titration. Titration every 3 minutes or every 24 hours provided oxygen savings estimated at 11.7% ± 5.1% and 8.1% ± 5.1% (average ± standard error of the mean, n = 3), respectively. For every 100 patients, 44 or 30 kiloliters would be saved-equivalent to 733 or 500 hours at 1 liter per minute. Ongoing titration can conserve oxygen, even performed once-daily. While clinical validation is necessary, these findings could provide incentive for the routine use of pulse oximeters for patient management, as well as further development of automated systems.

  12. Home blood pressure monitoring and self-titration of antihypertensive medications: Proposed patient selection criteria.

    PubMed

    Hill, James R

    2016-05-01

    Recent studies have demonstrated that home blood pressure monitoring (HBPM), coupled with self-titration of medications is a viable intervention to control hypertension. There are currently no established criteria to evaluate patients for inclusion in such a program. The purpose of this discussion is to propose criteria for determining if a patient is appropriate to participate in a program of HBPM and self-titration. Inclusion criteria for two self-titration trials were examined, and additional factors in clinical practice were identified and discussed. Additional selection criteria were proposed to support the decision to enroll a patient in an antihypertensive self-titration program. Inclusion criteria from self-titration trials provide a reasonable starting point for choosing appropriate patients in clinical practice, but additional research is necessary. Adaptation of these criteria and consideration of the identified factors can be used to develop decision support instruments. Such instruments should be evaluated for effectiveness and reliability prior to use in clinical practice. HBPM combined with self-titration is an effective patient-centered approach for hypertension management. Decision support instruments to determine appropriate patients are necessary for safe and effective use in clinical practice. ©2015 American Association of Nurse Practitioners.

  13. Thermometric titrations of amines with nitrosyl perchlorate in acetonitrile solvent.

    PubMed

    Gündüz, T; Kiliç, E; Cakirer, O

    1996-05-01

    Thirteen aliphatic and four aromatic amines, namely diethylamine, triethylamine, n-propylamine, di-n-propylamine, tri-n-butylamine, isopropylamine, di-isopropylamine, n-butylamine, di-n-butylamine, tri-n-butylamine, isobutylamine, sec-butylamine, tert-butylamine, aniline, N,N-dimethylaniline, 2-nitroaniline and 4-nitroaniline were titrated thermometrically with nitrosyl perchlorate in acetonitrile solvent. All the aliphatic amines gave very well-shaped thermometric titration curves. The calculated recovery values of the amines were very good. In comparison, the aromatic amines, aniline and N,N-dimethylaniline gave rather well-shaped titration curves, but the recovery values were fairly low. 2-Nitro- and 4-nitro anilines gave no thermometric response at all. The heats of reaction of the amines with nitrosyl perchlorate are rather high. However, the average heat of reaction of the aromatic amines is approximately two-thirds that of the average heat of the aliphatic amines. To support this method all the amines were also titrated potentiometrically and very similar results to those obtained with the thermometric method are seen. The nitrosyl ion is a Lewis acid, strong enough to titrate quantitatively aliphatic amines in acetonitrile solvent, but not strong enough to titrate aromatic amines at the required level in the same solvent.

  14. Assessment of residual active chlorine in sodium hypochlorite solutions after dissolution of porcine incisor pulpal tissue.

    PubMed

    Clarkson, R M; Smith, T K; Kidd, B A; Evans, G E; Moule, A J

    2013-12-01

    In previous studies, surfactant-containing Hypochlor brands of sodium hypochlorite showed better tissue solubilizing abilities than Milton; differences not explained by original active chlorine content or presence of surfactant. It was postulated that exhaustion of active chlorine content could explain differences. This study aimed to assess whether Milton's poorer performance was due to exhaustion of active chlorine. Parallel experiments assessed the influence of titration methods, and the presence of chlorates, on active chlorine measurements. Time required to dissolve one or groups of 10 samples of porcine incisor pulp samples in Milton was determined. Residual active chlorine was assessed by thermometric titration. Iodometric and thermometric titration was carried out on samples of Milton. Chlorate content was also measured. Dissolution of single and 10 pulp samples caused a mean loss of 1% and 3% respectively of active chlorine, not being proportional to tissue dissolved. Thermometric ammonium ion titration resulted in 10% lower values than iodometric titration. Chlorate accounted for much of this difference. Depletion of active chlorine is not the reason for differences in tissue dissolving capabilities of Milton. Thermometric ammonium ion titration gives more accurate measurement of active chlorine content than iodometric titration. © 2013 Australian Dental Association.

  15. Photometric followup investigations on LAMOST survey target Ly And

    NASA Astrophysics Data System (ADS)

    Lu, Hong-peng; Zhang, Li-yun; Han, Xianming L.; Pi, Qing-feng; Wang, Dai-mei

    2017-02-01

    We present a low-dispersion spectrum and two sets of CCD photometric light curves of the eclipsing binary LY And for the first time. The spectrum of LY And was classified as G2. We derived an updated ephemeris based on all previously available and our newly acquired minimum light times. Our analyses of LY And light curve minimum times reveals that the differences between calculated and observed minimum times for LY And can be represented by an upward parabolic curve, which means its orbital period is increasing with a rate of 1.88 (± 0.13) × 10-7 days/year. This increase in orbital period may be interpreted as mass transfer from the primary component to the secondary component, with a rate of dM1/dt = -4.54 × 10-8M⊙/year. By analyzing our CCD photometric light curves obtained in 2015, we obtained its photometric solution with the Wilson-Devinney program. This photometric solution also fits very well our light curves obtained in 2014. Our photometric solution shows that LY And is a contact eclipsing binary and its contact factor is f = (17.8 ± 1.9)%. Furthermore, both our spectroscopic and photometric data show no obvious chromospheric activity of LY And.

  16. The Potentiometric Titration of Filtrates from the Bachmann Process

    DTIC Science & Technology

    1942-06-23

    SCIENTIFIC RESEARCH AND DEVELOP11ENT The Potentiometric Titration of Filtrates from the Bachmann Process (OD-12) by F. C. Whitmore OSRD No. 654... Potentiometric Titration of Synthetic Mixtures. A? Nitric Acid-Acetic Acid. A sample of 60 ml. glacial acetic acid war diluted to 200 ml. with distilled...i4flinflr?fj3 TADLE 1 CO) |S?lDBnTl» POTENTIOMETRIC TITRATION OF SYNTHETIC t’.IXTURES WITH CONCENTRATED AJKDNIUM HYDROXIDE A; unonium HNO-j- AcOfi Ky

  17. Quantitative Determination of NTA and Other Chelating Agents in Detergents by Potentiometric Titration with Copper Ion Selective Electrode.

    PubMed

    Ito, Sana; Morita, Masaki

    2016-01-01

    Quantitative analysis of nitrilotriacetate (NTA) in detergents by titration with Cu 2+ solution using a copper ion selective electrode was achieved. This method tolerates a wide range of pH and ingredients in detergents. In addition to NTA, other chelating agents, having relatively lower stability constants toward Cu 2+ , were also qualified with sufficient accuracy by this analytical method for model detergent formulations. The titration process was automated by automatic titrating systems available commercially.

  18. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pauli, Adam T; Robertson, Raymond E; Branthaver, Jan F

    A system for determining parameters and compatibility of a substance such as an asphalt or other petroleum substance uses titration to highly accurately determine one or more flocculation occurrences and is especially applicable to the determination or use of Heithaus parameters and optimal mixing of various asphalt stocks. In a preferred embodiment, automated titration in an oxygen gas exclusive system and further using spectrophotometric analysis (2-8) of solution turbidity is presented. A reversible titration technique enabling in-situ titration measurement of various solution concentrations is also presented.

  19. A Microscale Spectrophotometric Determination of Water Hardness

    NASA Astrophysics Data System (ADS)

    Gordon, James S.

    2001-08-01

    A spectrophotometric titration was performed to determine water hardness. The titration incorporated the traditional titration method employing EDTA as the titrant and calmagite as the indicator. The microscale experiment was carried out in a spectrometer cuvette and made use of a Texas Instruments (TI-83) calculator interfaced through a TI Calculator-Based Laboratory system to a Vernier colorimeter as the detector. Monitoring at 635 nm, one of the colorimeter's fixed wavelengths, was well suited for this analysis. Agreement was found with results from traditional titrations.

  20. Process for Assessing the Stability of HAN (Hydroxylamine)-Based Liquid Propellants.

    DTIC Science & Technology

    1987-07-29

    liquid propellants on the basis of HAN according to Fig. 1 can be determined directly by Fischer titration. This method requires a special unit, as the...Wasserreagenzien nach Eugen Scholz fUr die Karl - Fischer -Titration (Guidelines by Messrs. Riedel-de Haen for Titration according to the Karl Fischer ...Propellant components 2 2.2 Methods of determination 3 2.3 Acid/base titration and pK values 4 2.4 The Titroprozessor 636 8 2.5 Propellant analyses 10

  1. Value of routine investigations to predict loop diuretic down-titration success in stable heart failure.

    PubMed

    Martens, Pieter; Verbrugge, Frederik H; Boonen, Levinia; Nijst, Petra; Dupont, Matthias; Mullens, Wilfried

    2018-01-01

    Guidelines advocate down-titration of loop diuretics in chronic heart failure (CHF) when patients have no signs of volume overload. Limited data are available on the expected success rate of this practice or how routine diagnostic tests might help steering this process. Fifty ambulatory CHF-patients on stable neurohumoral blocker/diuretic therapy for at least 3months without any clinical sign of volume overload were prospectively included to undergo loop diuretic down-titration. All patients underwent a similar pre-down-titration evaluation consisting of a dyspnea scoring, physical examination, transthoracic echocardiography (diastolic function, right ventricular function, cardiac filling pressures and valvular disease), blood sample (serum creatinine, plasma NT-pro-BNP and neurohormones). Loop diuretic maintenance dose was subsequently reduced by 50% or stopped if dose was ≤40mg furosemide equivalents. Successful down-titration was defined as a persistent dose reduction after 30days without weight increase >1.5kg or new-onset symptoms of worsening heart failure. At 30-day follow-up, down-titration was successful in 62% (n=31). In 12/19 patients exhibiting down-titration failure, this occurred within the first week. Physical examination, transthoracic echocardiography and laboratory analysis had limited predictive capability to detect patients with down-titration success/failure (positive likelihood-ratios below 1.5, or area under the curve [AUC] non-statically different from AUC=0.5). Loop diuretic down-titration is feasible in a majority of stable CHF patients in which the treating clinician felt continuation of loops was unnecessary to sustain euvolemia. Importantly, routine diagnostics which suggest euvolemia, have limited diagnostic impact on the post-test probability. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. Immediate effect of CPAP titration on perceived health related quality of life: a prospective observational study.

    PubMed

    Iacono Isidoro, Serena; Salvaggio, Adriana; Lo Bue, Anna; Romano, Salvatore; Marrone, Oreste; Insalaco, Giuseppe

    2016-12-01

    Perceived Health Related Quality of Life (HRQoL) is impaired in obstructive sleep apnea (OSA). This study examines changes in HRQoL aspects occurring immediately after CPAP titration. Furthermore, we analyzed variations in each gender and in patients undergoing home or laboratory-based CPAP titration pathways. Twohundredfive outpatients (151 M) (56.7 ± 10.3 years) were evaluated, before first visit and nocturnal diagnostic examination (T0), and the morning after CPAP titration (T1). Two self-reported HRQoL questionnaires were administered: Psychological General Well-Being Index (PGWBI), composed by six subscales, and 12-Item Short-Form Health Survey (SF-12), including Physical (PCS) and Mental Component Summaries (MCS). CPAP titration was performed using auto-adjusting CPAP units at patients' home or in the sleep laboratory. PGWBI scores at T1 improved compared to T0 (p < 0.0001). A similar improvement was observed in SF-12 MCS (p = 0.0011), but not in SF-12 PCS. Changes were independent from anthropometric parameters, OSA severity and excessive daytime sleepiness. Gender comparisons showed better HRQoL in males at both times. At T0, patients who received home or laboratory CPAP titration pathways did not show any differences in PGWBI and SF-12 scores. At T1, PGWBI and SF-12 MCS improved in both home and laboratory groups. This study gives evidence that first time CPAP application for titration can lead to a general increase in perceived well-being. Gender comparisons showed better perceived HRQoL with more subscales improvements in males after CPAP titration. The improvement was similar with both home and laboratory CPAP titration pathways.

  3. Effects of positive end-expiratory pressure titration and recruitment maneuver on lung inflammation and hyperinflation in experimental acid aspiration-induced lung injury.

    PubMed

    Ambrosio, Aline M; Luo, Rubin; Fantoni, Denise T; Gutierres, Claudia; Lu, Qin; Gu, Wen-Jie; Otsuki, Denise A; Malbouisson, Luiz M S; Auler, Jose O C; Rouby, Jean-Jacques

    2012-12-01

    In acute lung injury positive end-expiratory pressure (PEEP) and recruitment maneuver are proposed to optimize arterial oxygenation. The aim of the study was to evaluate the impact of such a strategy on lung histological inflammation and hyperinflation in pigs with acid aspiration-induced lung injury. Forty-seven pigs were randomly allocated in seven groups: (1) controls spontaneously breathing; (2) without lung injury, PEEP 5 cm H2O; (3) without lung injury, PEEP titration; (4) without lung injury, PEEP titration + recruitment maneuver; (5) with lung injury, PEEP 5 cm H2O; (6) with lung injury, PEEP titration; and (7) with lung injury, PEEP titration + recruitment maneuver. Acute lung injury was induced by intratracheal instillation of hydrochloric acid. PEEP titration was performed by incremental and decremental PEEP from 5 to 20 cm H2O for optimizing arterial oxygenation. Three recruitment maneuvers (pressure of 40 cm H2O maintained for 20 s) were applied to the assigned groups at each PEEP level. Proportion of lung inflammation, hemorrhage, edema, and alveolar wall disruption were recorded on each histological field. Mean alveolar area was measured in the aerated lung regions. Acid aspiration increased mean alveolar area and produced alveolar wall disruption, lung edema, alveolar hemorrhage, and lung inflammation. PEEP titration significantly improved arterial oxygenation but simultaneously increased lung inflammation in juxta-diaphragmatic lung regions. Recruitment maneuver during PEEP titration did not induce additional increase in lung inflammation and alveolar hyperinflation. In a porcine model of acid aspiration-induced lung injury, PEEP titration aimed at optimizing arterial oxygenation, substantially increased lung inflammation. Recruitment maneuvers further improved arterial oxygenation without additional effects on inflammation and hyperinflation.

  4. Impact of hypoglycemic events and HbA1c level on sulfonylurea discontinuation and down-titration.

    PubMed

    Laires, Pedro A; Tang, Jackson; Fan, Chun Po Steve; Li, Zhiyi; Qiu, Ying; Iglay, Kristy

    2017-04-01

    A retrospective cohort study using GE Centricity electronic medical records assessed the association between post-index hypoglycemia and HbA1c with discontinuation and down-titration of sulfonylureas among patients with Type 2 diabetes mellitus. Adult patients with an index prescription for a sulfonylurea and ≥12 months' continuous records pre- and post-index were eligible. Sulfonylurea discontinuation and down-titration was assessed 1-year post-index. Discontinuation occurred if the date of a prescription was >90 days from the preceding prescription plus days of supply. Down-titration occurred when a subsequent prescription was lower than the index dose. Cox regression assessed the association between post-index hypoglycemia and HbA1c with time to sulfonylurea discontinuation and down-titration, as well as other factors. 28,371 participants were included in the study; 13,459 (47.4%) were discontinuers, 717 (2.5%) were down-titraters, and 14,195 (50.0%) were continuers. 0.6% of continuers experienced hypoglycemia 1-year post-index, compared with 3.1% of down-titraters and 0.8% of discontinuers (p < 0.0001). Patients with post-index hypoglycemia had a significantly higher rate of discontinuation (hazard ratio [HR] = 1.82, 95% CI: 1.47-2.23) and down-titration (HR = 4.25, 95% CI: 1.92-8.03). Patients with higher post-index HbA1c and use of 2 nd generation sulfonylureas had an increased rate of discontinuation (HR = 1.05, 95% CI: 1.04-1.06; HR = 1.19, 95% CI: 1.14-1.24, respectively). Approximately half of participants who initiated sulfonylureas discontinued or down-titrated therapy within one year. Both post-index hypoglycemia and higher HbA1c were significant risk factors for sulfonylurea treatment change.

  5. Highly accurate nephelometric titrimetry.

    PubMed

    Zhan, Xiancheng; Li, Chengrong; Li, Zhiyi; Yang, Xiucen; Zhong, Shuguang; Yi, Tao

    2004-02-01

    A method that accurately indicates the end-point of precipitation reactions by the measurement of the relative intensity of the scattered light in the titrate is presented. A new nephelometric titrator with an internal nephelometric sensor has been devised. The work of the titrator including the sensor and change in the turbidity of the titrate and intensity of the scattered light are described. The accuracy of the nephelometric titrimetry is discussed theoretically. The titration of NaCl with AgNO(3) serves as a model. A relative error as well as deviation is within 0.2% under the experimental conditions. The applicability of the titrimetry in pharmaceutical analyses, for example, phenytoin sodium and procaine hydrochloride, is generally illustrated. Copyright 2004 Wiley-Liss, Inc. and the American Pharmacists Association

  6. Microtitration of various anions with quaternary ammonium halides using solid-state electrodes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Selig, W.

    1980-01-01

    Many solid-state electrodes were found to respond as endpoint detectors in the potentiometric titration of large inorganic and organic anions with quaternary ammonium halides. The best response was obtained with the iodide and cyanide electrodes although practically any electrode can function as endpoint sensor. The titrants were hexadecylpyridinium chloride and hexadecyltrimethylammonium chloride; hexadecyltrimethylammonium bromide and Hyamine 1622 may also be used. Some inorganic anions thus titratable are perrhenate, persulfate, ferricyanide, hexafluorophosphate, and hexachloroplatinate. Examples of organic anions titratable are nitroform, tetraphenylborate, cyanotriphenylborate, picrate, long-chain sulfates and sulfonates, and some soaps. The reverse titration of quaternary ammonium halides vs dodecylsulfate ismore » also feasible. Some titrations are feasible in a partially nonaqueous medium.« less

  7. Photometric Modeling of Simulated Surace-Resolved Bennu Images

    NASA Astrophysics Data System (ADS)

    Golish, D.; DellaGiustina, D. N.; Clark, B.; Li, J. Y.; Zou, X. D.; Bennett, C. A.; Lauretta, D. S.

    2017-12-01

    The Origins, Spectral Interpretation, Resource Identification, Security, Regolith Explorer (OSIRIS-REx) is a NASA mission to study and return a sample of asteroid (101955) Bennu. Imaging data from the mission will be used to develop empirical surface-resolved photometric models of Bennu at a series of wavelengths. These models will be used to photometrically correct panchromatic and color base maps of Bennu, compensating for variations due to shadows and photometric angle differences, thereby minimizing seams in mosaicked images. Well-corrected mosaics are critical to the generation of a global hazard map and a global 1064-nm reflectance map which predicts LIDAR response. These data products directly feed into the selection of a site from which to safely acquire a sample. We also require photometric correction for the creation of color ratio maps of Bennu. Color ratios maps provide insight into the composition and geological history of the surface and allow for comparison to other Solar System small bodies. In advance of OSIRIS-REx's arrival at Bennu, we use simulated images to judge the efficacy of both the photometric modeling software and the mission observation plan. Our simulation software is based on USGS's Integrated Software for Imagers and Spectrometers (ISIS) and uses a synthetic shape model, a camera model, and an empirical photometric model to generate simulated images. This approach gives us the flexibility to create simulated images of Bennu based on analog surfaces from other small Solar System bodies and to test our modeling software under those conditions. Our photometric modeling software fits image data to several conventional empirical photometric models and produces the best fit model parameters. The process is largely automated, which is crucial to the efficient production of data products during proximity operations. The software also produces several metrics on the quality of the observations themselves, such as surface coverage and the completeness of the data set for evaluating the phase and disk functions of the surface. Application of this software to simulated mission data has revealed limitations in the initial mission design, which has fed back into the planning process. The entire photometric pipeline further serves as an exercise of planned activities for proximity operations.

  8. Symmetry Properties of Potentiometric Titration Curves.

    ERIC Educational Resources Information Center

    Macca, Carlo; Bombi, G. Giorgio

    1983-01-01

    Demonstrates how the symmetry properties of titration curves can be efficiently and rigorously treated by means of a simple method, assisted by the use of logarithmic diagrams. Discusses the symmetry properties of several typical titration curves, comparing the graphical approach and an explicit mathematical treatment. (Author/JM)

  9. A Tabular Approach to Titration Calculations

    ERIC Educational Resources Information Center

    Lim, Kieran F.

    2012-01-01

    Titrations are common laboratory exercises in high school and university chemistry courses, because they are easy, relatively inexpensive, and they illustrate a number of fundamental chemical principles. While students have little difficulty with calculations involving a single titration step, there is a significant leap in conceptual difficulty…

  10. LIGHT TITRATIONS

    PubMed Central

    Field, John; Baas-Becking, Lourens G. M.

    1926-01-01

    1. The usefulness of the radiomicrometer in titration work has been pointed out. The authors suggest that light titration may also be used where a reaction mixture changes its absorption in the (near) infra-red. 2. The applicability of this method to the starch-iodine reaction has been demonstrated. PMID:19872266

  11. A Closer Look at Acid-Base Olfactory Titrations

    ERIC Educational Resources Information Center

    Neppel, Kerry; Oliver-Hoyo, Maria T.; Queen, Connie; Reed, Nicole

    2005-01-01

    Olfactory titrations using raw onions and eugenol as acid-base indicators are reported. An in-depth investigation on olfactory titrations is presented to include requirements for potential olfactory indicators and protocols for using garlic, onions, and vanillin as acid-base olfactory indicators are tested.

  12. Switching From Age-Based Stimulus Dosing to Dose Titration Protocols in Electroconvulsive Therapy: Empirical Evidence for Better Patient Outcomes With Lower Peak and Cumulative Energy Doses.

    PubMed

    O'Neill-Kerr, Alex; Yassin, Anhar; Rogers, Stephen; Cornish, Janie

    2017-09-01

    The aim of this study was to test the proposition that adoption of a dose titration protocol may be associated with better patient outcomes, at lower treatment dose, and with comparable cumulative dose to that in patients treated using an age-based stimulus dosing protocol. This was an analysis of data assembled from archived records and based on cohorts of patients treated respectively on an age-based stimulus dosing protocol and on a dose titration protocol in the National Health Service in England. We demonstrated a significantly better response in the patient cohort treated with dose titration than with age-based stimulus dosing. Peak doses were less and the total cumulative dose was less in the dose titration group than in the age-based stimulus dosing group. Our findings are consistent with superior outcomes in patients treated using a dose titration protocol when compared with age-based stimulus dosing in a similar cohort of patients.

  13. Potentiometric titration and equivalent weight of humic acid

    USGS Publications Warehouse

    Pommer, A.M.; Breger, I.A.

    1960-01-01

    The "acid nature" of humic acid has been controversial for many years. Some investigators claim that humic acid is a true weak acid, while others feel that its behaviour during potentiometric titration can be accounted for by colloidal adsorption of hydrogen ions. The acid character of humic acid has been reinvestigated using newly-derived relationships for the titration of weak acids with strong base. Re-interpreting the potentiometric titration data published by Thiele and Kettner in 1953, it was found that Merck humic acid behaves as a weak polyelectrolytic acid having an equivalent weight of 150, a pKa of 6.8 to 7.0, and a titration exponent of about 4.8. Interdretation of similar data pertaining to the titration of phenol-formaldehyde and pyrogallol-formaldehyde resins, considered to be analogs for humic acid by Thiele and Kettner, leads to the conclusion that it is not possible to differentiate between adsorption and acid-base reaction for these substances. ?? 1960.

  14. Effects of different crystal faces on the surface charge of colloidal goethite (α-FeOOH) particles: an experimental and modeling study

    NASA Astrophysics Data System (ADS)

    Gaboriaud, Fabien; Ehrhardt, Jean-Jacques

    2003-03-01

    The surface charge of colloidal particles is usually determined by potentiometric titration. These acid-base titrations make it possible to measure the pH of point-of-zero charge (pzc) for oxide minerals. This macroscopic property is the most important parameter used in surface complexation modeling to reproduce experimental data. The pzc values of goethite reported in the literature vary between 7.0 and 9.5. Carbonate adsorption and/or surface morphology are thought to account for this wide range. We demonstrate a procedure for the removal of the carbonate ions that initially adsorb on goethite and strongly affect the titration curves and pzc determination. We also investigated the crystal-face-specific reactivity of two morphologically different goethites. The z-profiles obtained from atomic force microscopy (AFM) images showed that the goethite with the smallest specific surface area ( S = 49 m 2/g, denoted G49) exhibits 70% of the (001) face, whereas this value is only 30% for the goethite with largest specific surface area ( S = 95 m 2/g, denoted G95). This morphologic difference results in slightly different pzc values: 9.0 for G49 goethite and 9.1 for G95 geothite. These experimental pzc values have been correlated with multisite complexation calculations using both the full-site and the 1-pK approaches. We used the full-site approach to consider all of the configurations of hydrogen bond interactions with surface site. The resulting mean charges gave estimated pzc values of 8.9 and 9.2 for the (001) and (101) faces, respectively. Considering these theoretical pzc values for individual faces and the face distributions obtained from AFM analysis, the calculated pzc values are in full agreement with the experimental pzc values. However, this morphologic difference is more expressed in surface charge values than in the pzc values. Indeed, the surface charge of G49 goethite is much higher than that of G95 goethite, and the 1-pK calculations make it possible to fit the titration data satisfactorily.

  15. Rapid multi-wavelength optical assessment of circulating blood volume without a priori data

    NASA Astrophysics Data System (ADS)

    Loginova, Ekaterina V.; Zhidkova, Tatyana V.; Proskurnin, Mikhail A.; Zharov, Vladimir P.

    2016-03-01

    The measurement of circulating blood volume (CBV) is crucial in various medical conditions including surgery, iatrogenic problems, rapid fluid administration, transfusion of red blood cells, or trauma with extensive blood loss including battlefield injuries and other emergencies. Currently, available commercial techniques are invasive and time-consuming for trauma situations. Recently, we have proposed high-speed multi-wavelength photoacoustic/photothermal (PA/PT) flow cytometry for in vivo CBV assessment with multiple dyes as PA contrast agents (labels). As the first step, we have characterized the capability of this technique to monitor the clearance of three dyes (indocyanine green, methylene blue, and trypan blue) in an animal model. However, there are strong demands on improvements in PA/PT flow cytometry. As additional verification of our proof-of-concept of this technique, we performed optical photometric CBV measurements in vitro. Three label dyes—methylene blue, crystal violet and, partially, brilliant green—were selected for simultaneous photometric determination of the components of their two-dye mixtures in the circulating blood in vitro without any extra data (like hemoglobin absorption) known a priori. The tests of single dyes and their mixtures in a flow system simulating a blood transfusion system showed a negligible difference between the sensitivities of the determination of these dyes under batch and flow conditions. For individual dyes, the limits of detection of 3×10-6 M‒3×10-6 M in blood were achieved, which provided their continuous determination at a level of 10-5 M for the CBV assessment without a priori data on the matrix. The CBV assessment with errors no higher than 4% were obtained, and the possibility to apply the developed procedure for optical photometric (flow cytometry) with laser sources was shown.

  16. THE GRISM LENS-AMPLIFIED SURVEY FROM SPACE (GLASS). IV. MASS RECONSTRUCTION OF THE LENSING CLUSTER ABELL 2744 FROM FRONTIER FIELD IMAGING AND GLASS SPECTROSCOPY

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, X.; Schmidt, K. B.; Jones, T. A.

    2015-09-20

    We present a strong and weak lensing reconstruction of the massive cluster Abell 2744, the first cluster for which deep Hubble Frontier Fields (HFF) images and spectroscopy from the Grism Lens-Amplified Survey from Space (GLASS) are available. By performing a targeted search for emission lines in multiply imaged sources using the GLASS spectra, we obtain five high-confidence spectroscopic redshifts and two tentative ones. We confirm one strongly lensed system by detecting the same emission lines in all three multiple images. We also search for additional line emitters blindly and use the full GLASS spectroscopic catalog to test reliability of photometricmore » redshifts for faint line emitters. We see a reasonable agreement between our photometric and spectroscopic redshift measurements, when including nebular emission in photometric redshift estimations. We introduce a stringent procedure to identify only secure multiple image sets based on colors, morphology, and spectroscopy. By combining 7 multiple image systems with secure spectroscopic redshifts (at 5 distinct redshift planes) with 18 multiple image systems with secure photometric redshifts, we reconstruct the gravitational potential of the cluster pixellated on an adaptive grid, using a total of 72 images. The resulting mass map is compared with a stellar mass map obtained from the deep Spitzer Frontier Fields data to study the relative distribution of stars and dark matter in the cluster. We find that the stellar to total mass ratio varies substantially across the cluster field, suggesting that stars do not trace exactly the total mass in this interacting system. The maps of convergence, shear, and magnification are made available in the standard HFF format.« less

  17. A systematic review on the effectiveness of titratable over nontitratable mandibular advancement appliances for sleep apnea.

    PubMed

    Sivaramakrishnan, Gowri; Sridharan, Kannan

    2017-01-01

    Mandibular advancement appliances are being tested for use in patients with obstructive sleep apnea (OSA). However, the effectiveness of titration of these appliances does not have conclusive evidence. Systematic reviews help us to compile all available clinical evidence using statistical principles. Hence, the aim of this systematic review is to identify the effectiveness of titratable over nontitratable mandibular advancement appliances in patients with mild to moderate OSA. This review objective is to identify if titration of these appliances produce significant benefits over fixed appliances. Electronic databases were searched to identify eligible studies based on set inclusion criteria. Data extraction form was created and the data were extracted. The participants were mild to moderate OSA patients who received mandibular advancement appliances. Studies included a comparison between titratable and nontitratable mandibular advancement appliance. Of the five included studies, three were observational and two were a randomized trial. All these studies were conducted in adults. The outcome attributes were polysomnographic readings and apnea-hypopnea index (AHI). A significant heterogeneity was seen between the eligible studies and hence a meta-analysis could not be performed. The results from this systematic review did not show significant advantages of titratable appliances, although titratable appliances performed better from individual studies as regards to reduction in AHI and polysomnography. The reason is the lack of sufficient clinical trials on the same. More high quality randomized controlled trials comparing titratable and fixed appliances have to be initiated to get to conclusive evidence.

  18. SCAMP: Automatic Astrometric and Photometric Calibration

    NASA Astrophysics Data System (ADS)

    Bertin, Emmanuel

    2010-10-01

    Astrometric and photometric calibrations have remained the most tiresome step in the reduction of large imaging surveys. SCAMP has been written to address this problem. The program efficiently computes accurate astrometric and photometric solutions for any arbitrary sequence of FITS images in a completely automatic way. SCAMP is released under the GNU General Public License.

  19. Galaxy Tagging: photometric redshift refinement and group richness enhancement

    NASA Astrophysics Data System (ADS)

    Kafle, P. R.; Robotham, A. S. G.; Driver, S. P.; Deeley, S.; Norberg, P.; Drinkwater, M. J.; Davies, L. J.

    2018-06-01

    We present a new scheme, galtag, for refining the photometric redshift measurements of faint galaxies by probabilistically tagging them to observed galaxy groups constructed from a brighter, magnitude-limited spectroscopy survey. First, this method is tested on the DESI light-cone data constructed on the GALFORM galaxy formation model to tests its validity. We then apply it to the photometric observations of galaxies in the Kilo-Degree Imaging Survey (KiDS) over a 1 deg2 region centred at 15h. This region contains Galaxy and Mass Assembly (GAMA) deep spectroscopic observations (i-band<22) and an accompanying group catalogue to r-band<19.8. We demonstrate that even with some trade-off in sample size, an order of magnitude improvement on the accuracy of photometric redshifts is achievable when using galtag. This approach provides both refined photometric redshift measurements and group richness enhancement. In combination these products will hugely improve the scientific potential of both photometric and spectroscopic datasets. The galtag software will be made publicly available at https://github.com/pkaf/galtag.git.

  20. FAST: Fitting and Assessment of Synthetic Templates

    NASA Astrophysics Data System (ADS)

    Kriek, Mariska; van Dokkum, Pieter G.; Labbé, Ivo; Franx, Marijn; Illingworth, Garth D.; Marchesini, Danilo; Quadri, Ryan F.; Aird, James; Coil, Alison L.; Georgakakis, Antonis

    2018-03-01

    FAST (Fitting and Assessment of Synthetic Templates) fits stellar population synthesis templates to broadband photometry and/or spectra. FAST is compatible with the photometric redshift code EAzY (ascl:1010.052) when fitting broadband photometry; it uses the photometric redshifts derived by EAzY, and the input files (for examply, photometric catalog and master filter file) are the same. FAST fits spectra in combination with broadband photometric data points or simultaneously fits two components, allowing for an AGN contribution in addition to the host galaxy light. Depending on the input parameters, FAST outputs the best-fit redshift, age, dust content, star formation timescale, metallicity, stellar mass, star formation rate (SFR), and their confidence intervals. Though some of FAST's functions overlap with those of HYPERZ (ascl:1108.010), it differs by fitting fluxes instead of magnitudes, allows the user to completely define the grid of input stellar population parameters and easily input photometric redshifts and their confidence intervals, and calculates calibrated confidence intervals for all parameters. Note that FAST is not a photometric redshift code, though it can be used as one.

  1. Antiepileptic Drug Titration and Related Health Care Resource Use and Costs.

    PubMed

    Fishman, Jesse; Kalilani, Linda; Song, Yan; Swallow, Elyse; Wild, Imane

    2018-02-27

    Unexpected breakthrough seizures resulting from suboptimal antiepileptic drug (AED) dosing during the titration period, as well as adverse events resulting from rapid AED titration, may influence the titration schedule and significantly increase health care resource use (HRU) and health care costs. To assess the relationship between AEDs, HRU, and costs during AED titration and maintenance. Practicing neurologists were recruited from a nationwide panel to provide up to 3 patient records each for this retrospective medical chart review. Patients with epilepsy who were aged ≥ 18 years and had initiated an AED between January 1, 2014, and January 1, 2016, were followed for 6 months from AED initiation. Titration duration was the time from AED initiation to the beginning of treatment maintenance as determined by the physician. Outcomes were epilepsy-specific HRU (hospitalizations, emergency department visits, outpatient visits, physician referral, laboratory testing/diagnostic imaging, and phone calls) and related costs that occurred during the titration or maintenance treatment periods. Of 811 patients, 156, 128, 125, 120, 114, 107, and 61 initiated the following AEDs: levetiracetam, lamotrigine, lacosamide, valproate, topiramate, carbamazepine, and phenytoin, respectively. Most patients (619/803 [77.1%] with complete AED data) received monotherapy. Baseline characteristics were similar across AEDs (mean [SD] age, 36.6 [14.4] years; 59.0% male). Kaplan-Meier estimates of titration duration ranged from 3.3 weeks (phenytoin) to 8.1 weeks (lamotrigine). From titration to maintenance, the overall incidence of HRU per person-month decreased 54.5%-89.3% for each HRU measure except outpatient visits (24.6% decrease). Total epilepsy-related costs decreased from $80.48 to $42.77 per person-month, or 46.9% from titration to maintenance. AED titration periods had higher HRU rates and costs than AED maintenance, suggesting that use of AEDs with shorter titration requirements reduces health care costs, although disease severity may also factor into overall cost. UCB Pharma sponsored this study and reviewed the manuscript. Fishman and Kalilani are employees of UCB Pharma. Wild was an employee of UCB Pharma at the time this analysis was conducted. Song and Swallow are employees of Analysis Group, which received funding from UCB Pharma. Study concept and design were contributed by Fishman, Kalilani, and Wild, along with other authors. Data collection was performed by Song and Swallow. All authors contributed to data interpretation. Writing of the manuscript was led by Fishman, Song, and Swallow, with revisions by all authors.

  2. Broadband radiometric LED measurements

    NASA Astrophysics Data System (ADS)

    Eppeldauer, G. P.; Cooksey, C. C.; Yoon, H. W.; Hanssen, L. M.; Podobedov, V. B.; Vest, R. E.; Arp, U.; Miller, C. C.

    2016-09-01

    At present, broadband radiometric LED measurements with uniform and low-uncertainty results are not available. Currently, either complicated and expensive spectral radiometric measurements or broadband photometric LED measurements are used. The broadband photometric measurements are based on the CIE standardized V(λ) function, which cannot be used in the UV range and leads to large errors when blue or red LEDs are measured in its wings, where the realization is always poor. Reference irradiance meters with spectrally constant response and high-intensity LED irradiance sources were developed here to implement the previously suggested broadband radiometric LED measurement procedure [1, 2]. Using a detector with spectrally constant response, the broadband radiometric quantities of any LEDs or LED groups can be simply measured with low uncertainty without using any source standard. The spectral flatness of filtered-Si detectors and low-noise pyroelectric radiometers are compared. Examples are given for integrated irradiance measurement of UV and blue LED sources using the here introduced reference (standard) pyroelectric irradiance meters. For validation, the broadband measured integrated irradiance of several LED-365 sources were compared with the spectrally determined integrated irradiance derived from an FEL spectral irradiance lamp-standard. Integrated responsivity transfer from the reference irradiance meter to transfer standard and field UV irradiance meters is discussed.

  3. Probabilistic Photometric Redshifts in the Era of Petascale Astronomy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Carrasco Kind, Matias

    2014-01-01

    With the growth of large photometric surveys, accurately estimating photometric redshifts, preferably as a probability density function (PDF), and fully understanding the implicit systematic uncertainties in this process has become increasingly important. These surveys are expected to obtain images of billions of distinct galaxies. As a result, storing and analyzing all of these photometric redshift PDFs will be non-trivial, and this challenge becomes even more severe if a survey plans to compute and store multiple different PDFs. In this thesis, we have developed an end-to-end framework that will compute accurate and robust photometric redshift PDFs for massive data sets bymore » using two new, state-of-the-art machine learning techniques that are based on a random forest and a random atlas, respectively. By using data from several photometric surveys, we demonstrate the applicability of these new techniques, and we demonstrate that our new approach is among the best techniques currently available. We also show how different techniques can be combined by using novel Bayesian techniques to improve the photometric redshift precision to unprecedented levels while also presenting new approaches to better identify outliers. In addition, our framework provides supplementary information regarding the data being analyzed, including unbiased estimates of the accuracy of the technique without resorting to a validation data set, identification of poor photometric redshift areas within the parameter space occupied by the spectroscopic training data, and a quantification of the relative importance of the variables used during the estimation process. Furthermore, we present a new approach to represent and store photometric redshift PDFs by using a sparse representation with outstanding compression and reconstruction capabilities. We also demonstrate how this framework can also be directly incorporated into cosmological analyses. The new techniques presented in this thesis are crucial to enable the development of precision cosmology in the era of petascale astronomical surveys.« less

  4. VizieR Online Data Catalog: UV-excess quasar candidates (Moreau+, 1995)

    NASA Astrophysics Data System (ADS)

    Moreau, O.; Reboul, H.

    1995-01-01

    We have developed a procedure (so called PAPA) for measurement of magnitudes (about 0.1mag accurate) and positions (with accuracy better than 0.5arcsec) of all the objects present on photographic plates digitised with the MAMA machine. This homogeneous procedure was applied to four Schmidt plates - in U, B and twice V - covering the Palomar-Sky-Survey field PS +30deg 13h00m, a 40-square-degree zone at the North Galactic Pole. A general-interest exhaustive tricolour catalogue of 19542 star-like objects down to V=20.0 has been produced and we selected 1681 quasar candidates on the basis of ultraviolet excess and, when possible, absence of any measurable proper motion. The astrometric and photometric catalogue of the candidates is given in electronic form. (4 data files).

  5. Photometric theory for wide-angle phenomena

    NASA Technical Reports Server (NTRS)

    Usher, Peter D.

    1990-01-01

    An examination is made of the problem posed by wide-angle photographic photometry, in order to extract a photometric-morphological history of Comet P/Halley. Photometric solutions are presently achieved over wide angles through a generalization of an assumption-free moment-sum method. Standard stars in the field allow a complete solution to be obtained for extinction, sky brightness, and the characteristic curve. After formulating Newton's method for the solution of the general nonlinear least-square problem, an implementation is undertaken for a canonical data set. Attention is given to the problem of random and systematic photometric errors.

  6. Monosodium glutamate for simple photometric iron analysis

    NASA Astrophysics Data System (ADS)

    Prasetyo, E.

    2018-01-01

    Simple photometric method for iron analysis using monosodium glutamate (MSG) was proposed. The method could be used as an alternative method, which was technically simple, economic, quantitative, readily available, scientifically sound and environmental friendly. Rapid reaction of iron (III) with glutamate in sodium chloride-hydrochloric acid buffer (pH 2) to form red-brown complex was served as a basis in the photometric determination, which obeyed the range of iron (III) concentration 1.6 - 80 µg/ml. This method could be applied to determine iron concentration in soil with satisfactory results (accuracy and precision) compared to other photometric and atomic absorption spectrometry results.

  7. Application of Computers for Experiment Design, Data Acquisition, and Analysis in the Chemistry Laboratory

    DTIC Science & Technology

    1990-05-01

    Obtain Thermistor Operating Characteristics ................................. 82 25. Ag+/Ci" Thermometric Titration ........................... 85 26...Experiment Program for Thermometric Titrations ............... 85 27. Appearance of the Spreadsheet in the Analysis Mode ............ 86 28...rate experiments, carbon dioxide exhalation monitoring, stream turbidity measurement, photosynthesis monitoring, pendulum timing, thermometric titrations

  8. Comparison of methods for accurate end-point detection of potentiometric titrations

    NASA Astrophysics Data System (ADS)

    Villela, R. L. A.; Borges, P. P.; Vyskočil, L.

    2015-01-01

    Detection of the end point in potentiometric titrations has wide application on experiments that demand very low measurement uncertainties mainly for certifying reference materials. Simulations of experimental coulometric titration data and consequential error analysis of the end-point values were conducted using a programming code. These simulations revealed that the Levenberg-Marquardt method is in general more accurate than the traditional second derivative technique used currently as end-point detection for potentiometric titrations. Performance of the methods will be compared and presented in this paper.

  9. Determination of organic bases in non-aqueous solvents by catalytic thermometric titration.

    PubMed

    Vajgand, V J; Kiss, T A; Gaál, F F; Zsigrai, I J

    1968-07-01

    Catalytic thermometric titrations have been developed for bases (brucine, diethylaniline, potassium acetate and triethylamine) in acetic acid by continuous and discontinuous addition of the standard solution and automatic temperature recording. The determination of weak bases, e.g., antipyrine, unsuccessful in acetic acid by catalytic thermometric titration, has been achieved by using nitromethane or acetic anhydride as solvent. Catalytic thermometric titrations were also performed by coulometric generation of hydrogen ions for the determination of micro amounts of weak bases in a mixture of acetic anhyride and acetic acid.

  10. Linear Titration Curves of Acids and Bases.

    PubMed

    Joseph, N R

    1959-05-29

    The Henderson-Hasselbalch equation, by a simple transformation, becomes pH - pK = pA - pB, where pA and pB are the negative logarithms of acid and base concentrations. Sigmoid titration curves then reduce to straight lines; titration curves of polyelectrolytes, to families of straight lines. The method is applied to the titration of the dipeptide glycyl aminotricarballylic acid, with four titrable groups. Results are expressed as Cartesian and d'Ocagne nomograms. The latter is of a general form applicable to polyelectrolytes of any degree of complexity.

  11. Titration effectiveness of two autoadjustable continuous positive airway pressure devices driven by different algorithms in patients with obstructive sleep apnoea.

    PubMed

    Damiani, Mario Francesco; Quaranta, Vitaliano Nicola; Tedeschi, Ersilia; Drigo, Riccardo; Ranieri, Teresa; Carratù, Pierluigi; Resta, Onofrio

    2013-08-01

    Nocturnal application of continuous positive airway pressure (CPAP) is the standard treatment for patients with obstructive sleep apnoea (OSA). Determination of the therapeutic pressure (CPAP titration) is usually performed by a technician in the sleep laboratory during attended polysomnography. One possible alternative to manual titration is automated titration. Indeed, during the last 15 years, devices have been developed that deliver autoadjustable CPAP (A-CPAP). The aim of the present study was to compare the titration effectiveness of two A-CPAP devices using different flow-based algorithms in patients with OSA. This is a randomized study; 79 subjects underwent two consecutive unattended home A-CPAP titration nights with two different devices (Autoset Resmed; Remstar Auto Respironics); during the third and the fourth night, patients underwent portable monitoring in the sleep laboratory during fixed CPAP at the A-CPAP recommended pressure. Bland Altman plots showed good agreement between the recommended median and maximal pressure levels obtained with the two devices. A significant improvement was observed in all the sleep parameters by both A-CPAP machines to a similar degree. It was observed that the two A-CPAP devices using different algorithms are equally effective in initial titration of CPAP. © 2013 The Authors. Respirology © 2013 Asian Pacific Society of Respirology.

  12. Overall Survival Analysis From a Randomized Phase II Study of Axitinib With or Without Dose Titration in First-Line Metastatic Renal Cell Carcinoma.

    PubMed

    Rini, Brian I; Tomita, Yoshihiko; Melichar, Bohuslav; Ueda, Takeshi; Grünwald, Viktor; Fishman, Mayer N; Uemura, Hirotsugu; Oya, Mototsugu; Bair, Angel H; Andrews, Glen I; Rosbrook, Brad; Jonasch, Eric

    2016-12-01

    In a randomized phase II trial in metastatic renal cell carcinoma (mRCC), objective response rate was significantly higher with axitinib versus placebo titration (54% vs. 34%; 1-sided P = .019). Treatment-naive patients with mRCC (n = 213) received axitinib 5 mg twice per day (b.i.d.) for 4 weeks. Patients meeting dose titration criteria were randomized to receive axitinib 5 mg b.i.d. with axitinib or placebo titration (n = 56 each); 91 patients ineligible for randomization continued axitinib 5 mg b.i.d.; 10 discontinued before randomization. Median overall survival (95% confidence interval [CI]) was 42.7 months (24.7-not estimable) with axitinib titration versus 30.4 months (23.7-45.0) with placebo titration (stratified hazard ratio, 0.785; 95% CI, 0.485-1.272; 1-sided P = .162), and 41.6 months (95% CI, 33.0-not estimable) in nonrandomized patients. Safety data were consistent with previous reports. Median overall survival was numerically longer in patients with first-line mRCC who received axitinib versus placebo titration. No new safety signal was observed after long-term axitinib treatment in first-line mRCC. Copyright © 2016 Elsevier Inc. All rights reserved.

  13. A 24-Week, Randomized, Controlled Study to Evaluate the Tolerability, Safety and Efficacy of 2 Different Titration Schemes of the Rivastigmine Patch in Japanese Patients with Mild to Moderate Alzheimer's Disease.

    PubMed

    Nakamura, Yu; Strohmaier, Christine; Tamura, Kaoru; Kataoka, Naoko; Nakano, Masayuki; Oda, Shoichiro; Nishimura, Kazuma; Homma, Akira

    2015-01-01

    To investigate whether 1-step titration of the rivastigmine patch (initiated at 5 cm(2) and titrated to 10 cm(2) after 4 weeks) is well tolerated in Japanese patients with Alzheimer's disease (AD) as compared to 3-step titration (initiated at 2.5 cm(2) and titrated by 2.5 cm(2) every 4 weeks to 10 cm(2)). A 24-week, multicenter, randomized, double-blind study was conducted in Japan between July 2012 and May 2014. Patients with mild to moderate AD aged 50-85 years were randomized 1:1 to 1-step or 3-step titration of the rivastigmine once-daily patch. The primary endpoint was the proportion of patients with adverse events leading to discontinuation. Of 216 patients randomized, 215 (1-step, n = 107; 3-step, n = 108) were included in the safety analysis. The primary endpoint outcome was 15.0% in the 1-step group and 18.5% in the 3-step group. The observed treatment difference was -3.6% (95% confidence interval: -17.0, 9.6), falling within the prespecified acceptance range. The tolerability of two different titration schemes was similar in Japanese patients with AD.

  14. A 24-Week, Randomized, Controlled Study to Evaluate the Tolerability, Safety and Efficacy of 2 Different Titration Schemes of the Rivastigmine Patch in Japanese Patients with Mild to Moderate Alzheimer's Disease

    PubMed Central

    Nakamura, Yu; Strohmaier, Christine; Tamura, Kaoru; Kataoka, Naoko; Nakano, Masayuki; Oda, Shoichiro; Nishimura, Kazuma; Homma, Akira

    2015-01-01

    Aim To investigate whether 1-step titration of the rivastigmine patch (initiated at 5 cm2 and titrated to 10 cm2 after 4 weeks) is well tolerated in Japanese patients with Alzheimer's disease (AD) as compared to 3-step titration (initiated at 2.5 cm2 and titrated by 2.5 cm2 every 4 weeks to 10 cm2). Methods A 24-week, multicenter, randomized, double-blind study was conducted in Japan between July 2012 and May 2014. Patients with mild to moderate AD aged 50-85 years were randomized 1:1 to 1-step or 3-step titration of the rivastigmine once-daily patch. The primary endpoint was the proportion of patients with adverse events leading to discontinuation. Results Of 216 patients randomized, 215 (1-step, n = 107; 3-step, n = 108) were included in the safety analysis. The primary endpoint outcome was 15.0% in the 1-step group and 18.5% in the 3-step group. The observed treatment difference was −3.6% (95% confidence interval: −17.0, 9.6), falling within the prespecified acceptance range. Conclusion The tolerability of two different titration schemes was similar in Japanese patients with AD. PMID:26557135

  15. A model for oxygen conservation associated with titration during pediatric oxygen therapy

    PubMed Central

    Wu, Grace; Wollen, Alec; Himley, Stephen; Austin, Glenn; Delarosa, Jaclyn; Izadnegahdar, Rasa; Ginsburg, Amy Sarah; Zehrung, Darin

    2017-01-01

    Background Continuous oxygen treatment is essential for managing children with hypoxemia, but access to oxygen in low-resource countries remains problematic. Given the high burden of pneumonia in these countries and the fact that flow can be gradually reduced as therapy progresses, oxygen conservation through routine titration warrants exploration. Aim To determine the amount of oxygen saved via titration during oxygen therapy for children with hypoxemic pneumonia. Methods Based on published clinical data, we developed a model of oxygen flow rates needed to manage hypoxemia, assuming recommended flow rate at start of therapy, and comparing total oxygen used with routine titration every 3 minutes or once every 24 hours versus no titration. Results Titration every 3 minutes or every 24 hours provided oxygen savings estimated at 11.7% ± 5.1% and 8.1% ± 5.1% (average ± standard error of the mean, n = 3), respectively. For every 100 patients, 44 or 30 kiloliters would be saved—equivalent to 733 or 500 hours at 1 liter per minute. Conclusions Ongoing titration can conserve oxygen, even performed once-daily. While clinical validation is necessary, these findings could provide incentive for the routine use of pulse oximeters for patient management, as well as further development of automated systems. PMID:28234903

  16. Galactic and zodiacal light surface brightness measurements with the Atmosphere Explorer satellites

    NASA Technical Reports Server (NTRS)

    Abreu, V. J.; Hays, P. B.; Yee, J. H.

    1982-01-01

    Galactic and zodiacal light surface maps based on the Atmosphere Explorer-C, -D, and -E satellite data are presented at 7320, 6300, 5577, 5200, and 4278 A. A procedure used to generate these maps, which involves separation of the individual stars and diffuse starlight from the zodiacal light, is described in detail. The maps can be used in atmospheric emission studies to correct for galactic emissions which contaminate satellite as well as ground-based photometric observations. The zodiacal light maps show enhanced features which are important for understanding the nature of interplanetary dust.

  17. Techniques and Procedures Applied to Photometric Methods for the Analysis of Human Kinematic Responses to Impact Environments.

    DTIC Science & Technology

    1980-10-01

    t . " . . for ah ’ :i 2., :,. "-L ~ : . h for each fr se in’: the i,", -. .. :.t . ,-arameter TPA " he, :1: . . . I XL D(I = j a’ n i where index 3...are used to compute the reference angle R R=arctan (ZI/ Xl ) If - is less than zero, then 6 =R + 360.R R This is the reference angle between the range...similar anthropometry in pairs for comparative analysis. The data presented herein were derived from cinematographic recordings of the body segment

  18. Photometric Analysis and Transit Times of TRAPPIST-1 B and C

    NASA Astrophysics Data System (ADS)

    Morris, Brett M.; Agol, Eric; Hawley, Suzanne L.

    2018-01-01

    TRAPPIST-1 hosts seven Earth-sized planets transiting an M8 star. We observed mid-transit times of each of the inner two planets with the Astrophysical Research Consortium (ARC) 3.5 m Telescope at Apache Point Observatory (APO) to help constrain the planet masses with transit timing variations, and we outline a procedure for analyzing transit observations of late-M stars with APO. The transit times of TRAPPIST-1 b and c are $\\mathrm{BJD}_{\\mathrm{TDB}} = 2457580.87634^{+0.00034}_{-0.00034}$ and $2457558.89477^{+0.00080}_{-0.00085}$, respectively, which will help constrain the planet masses.

  19. Structural and spectroscopic characterizations on the charge-transfer interactions of the second generation poly(propylene amine) dendrimers with iodine and picric acid acceptors.

    PubMed

    El-Sayed, Mohamed Y; Refat, Moamen S

    2015-02-25

    Herein, this study was focused to get a knowledge about the intermolecular charge transfer complexes between the second generation of poly(propylene amine) dendrimer (PPD2) with picric acid (PA) and iodine (I2) as π and σ-acceptors. The charge-transfer interaction of the PPD2 electron donor and the PA acceptor has been studied in CHCl3. The resulted data refereed to the formation of the new CT-complex with the general formula [(PPD2)(PA)4]. The 1:4 stoichiometry of the reaction was discussed upon the on elemental analysis and photometric titration. On the other hand, the 1:3½ iodine-PPD2 heptaiodide (I7(-)) charge-transfer complex has been studied spectrophotometrically in chloroform at room temperature with general formula [(PPD2)](+)I7(-). The electronic absorption bands of 2I2·I3(-) (I7(-)) are observed at 358 and 294 nm. Raman laser spectrum of the brown solid heptaiodide complex has two clearly vibration bands at 155 and 110 cm(-1) due to symmetric stretching νs(II) outer and inner bonds, respectively. The (1)H NMR spectra and differential scanning calorimetry (DSC) data of PPD2 charge-transfer complexes were discussed. Copyright © 2014 Elsevier B.V. All rights reserved.

  20. Preparation, spectroscopic and structural studies on charge-transfer complexes of 2,9-dimethyl-1,10-phenanthroline with some electron acceptors

    NASA Astrophysics Data System (ADS)

    Gaballa, Akmal S.; Wagner, Christoph; Teleb, Said M.; Nour, El-Metwally; Elmosallamy, M. A. F.; Kaluđerović, Goran N.; Schmidt, Harry; Steinborn, Dirk

    2008-03-01

    Charge-transfer (CT) complexes formed in the reactions of 2,9-dimethyl-1,10-phenanthroline (Me 2phen) with some acceptors such as chloranil (Chl), picric acid (HPA) and chloranilic acid (H 2CA) have been studied in the defined solvent at room temperature. Based on elemental analysis and infrared spectra of the solid CT-complexes along with the photometric titration curves for the reactions, obtained data indicate the formation of 1:1 charge-transfer complexes [(Me 2phen)(Chl)] ( 1), [(Me 2phenH)(PA)] ( 2) and [(Me 2phenH)(HCA)] ( 3), respectively, was proposed. In the three complexes, infrared and 1H NMR spectroscopic data indicate a charge-transfer interaction and as far as complexes 2 and 3 are concerned this interaction is associated with a hydrogen bonding. The formation constants for the complexes ( KC) were shown to be dependent upon the nature of the electron acceptors used. The X-ray structure of complex 3 indicate the formation of dimeric units [Me 2phenH] 2[(HCA) 2] in which the two anions (HCA) - are connected by two O-H⋯O hydrogen bonds whereas the cations and anions are joined together by strong three-center (bifurcated) N-H⋯O hydrogen bonds. Furthermore, the cations are arranged in a π-π stacking.

  1. Spectrophotometric study on the proton transfer reaction between 2-amino-4-methylpyridine with 2,6-dichloro-4-nitrophenol in methanol, acetonitrile and the binary mixture 50% methanol + 50% acetonitrile

    NASA Astrophysics Data System (ADS)

    Al-Ahmary, Khairia M.; Habeeb, Moustafa M.; Al-Obidan, Areej H.

    2016-02-01

    Proton transfer reaction between 2-amino-4-methylpyridine (2AMP) as the proton acceptor with 2,6-dichloro-4-nitrophenol (DCNP) as the proton donor has been investigated spectrophotometrically in methanol (MeOH), acetonitrile (AN) and a binary mixture composed of 50% MeOH and 50% AN (AN-Me). The composition of the complex has been investigated utilizing Job's and photometric titration methods to be 1:1. Minimum-maximum absorbance equation has been applied to estimate the formation constant of the proton transfer reaction (KPT) where it reached high values in the investigated solvent confirming its high stability. The formation constant recorded higher value in AN compared with MeOH and mixture of AN-Me. Based on the formation of stable proton transfer complex, a sensitive spectrophotometric method was suggested for quantitative determination of 2AMP. The Lambert-Beer's law was obeyed in the concentration range 0.5-8 μg mL- 1 with small values of limits of detection and quantification. The solid complex between 2AMP with DCNP has been synthesized and characterized by elemental analysis to be 1:1 in concordant with the molecular stoichiometry in solution. Further analysis of the solid complex was carried out using infrared and 1H NMR spectroscopy.

  2. Improving Heart rate variability in sleep apnea patients: differences in treatment with auto-titrating positive airway pressure (APAP) versus conventional CPAP.

    PubMed

    Karasulu, Levent; Epöztürk, Pinar Ozkan; Sökücü, Sinem Nedime; Dalar, Levent; Altin, Sedat

    2010-08-01

    The effect of positive airway pressure treatments in different modalities on the cardiovascular consequences of the disease in sleep apnea patients is still unclear. We aimed to compare auto-titrating positive airway pressure (APAP) and conventional continuous positive airway pressure (CPAP) in terms of improving heart rate variability (HRV) in obstructive sleep apnea patients. This was a prospective study done in a tertiary research hospital. All patients underwent a manual CPAP titration procedure to determine the optimal pressure that abolishes abnormal respiratory events. Then patients underwent two treatment nights, one under APAP mode and one under conventional CPAP mode with a 1-week interval. Forty newly diagnosed obstructive sleep apnea patients were enrolled in the study. We compared heart rate variability analysis parameters between the APAP night and the CPAP night. This final analysis included the data of 28 patients (M/F: 22/6; mean age = 46 +/- 10 years). Sleep characteristics were comparable between the two treatment nights, whereas all-night time domains of HRV analysis such as HF, nuLF, and LF/HF were different between APAP and CPAP nights (2.93 +/- 0.31 vs. 3.01 +/- 0.31; P = 0.041; 0.75 +/- 0.13 vs. 0.71 +/- 0.14; P = 0.027; and 4.37 +/- 3.24 vs. 3.56 +/- 2.07; P = 0.023, respectively). HRV analysis for individual sleep stages showed that Stage 2 LF, nuLF, nuHF, LF/HF parameters entirely improved under CPAP treatment whereas APAP treatment resulted in nonsignificant changes. These results suggest that despite comparable improvement in abnormal respiratory events with APAP or CPAP treatments, CPAP may be superior to APAP in terms of correcting cardiovascular alterations in sleep apnea patients.

  3. Clozapine Titration for People in Early Psychosis: A Chart Review and Treatment Guideline.

    PubMed

    Ballon, Jacob S; Ashfaq, Hera; Noordsy, Douglas L

    2018-06-01

    The use of clozapine, particularly in young people, is often limited by early treatment-emergent adverse effects including drowsiness and lethargy. Concerns about adverse effects, medication adherence, and the need for blood monitoring often impede the use of clozapine in this population, leading to repeated trials of less effective medications. Current clozapine dosing recommendations are based on people further in the course of their illness and thus reflect different responsiveness and sensitivities to antipsychotic medication. As such, there is a need for evidence-based guidelines for titration and dosing of clozapine among people in early psychosis. We performed a chart review of 14 people treated with clozapine within our early psychosis team. Data regarding dose titration, response, time to discontinuation, symptom severity, weight gain, and other adverse effects were gathered at clozapine initiation, 3 months, and last available visit on clozapine. People treated with slow titration within their first year of psychosis onset achieved sustained response at very low maintenance doses (mean dose = 81 mg/d, mean duration of treatment = 200 weeks) compared with slow titration with longer duration of illness (mean dose = 350 mg/d, mean duration of treatment = 68 weeks) or standard dose titration in early psychosis (mean dose = 112 mg/d, mean duration of treatment = 38 weeks). The most common adverse effects in all groups were weight gain and sedation, with the groups requiring higher mean doses reporting a broader range of adverse effects. There was no apparent difference in the clinical global impression for severity or improvement between the slow titration and standard titration groups in people with early psychosis. These observations are synthesized into a proposed treatment guideline for use of clozapine among people in early psychosis. We describe development of a slow titration approach to initiating clozapine among people in early psychosis. This approach resulted in clinical response at remarkably low maintenance doses of clozapine among people within their first year of illness, but not in those with longer duration of symptoms. Slow titration also led to good tolerability and acceptance of clozapine treatment for some patients.

  4. Oxygen titration after resuscitation from out-of-hospital cardiac arrest: A multi-centre, randomised controlled pilot study (the EXACT pilot trial).

    PubMed

    Bray, Janet E; Hein, Cindy; Smith, Karen; Stephenson, Michael; Grantham, Hugh; Finn, Judith; Stub, Dion; Cameron, Peter; Bernard, Stephen

    2018-04-21

    Recent studies suggest the administration of 100% oxygen to hyperoxic levels following return-of-spontaneous-circulation (ROSC) post-cardiac arrest may be harmful. However, the feasibility and safety of oxygen titration in the prehospital setting is unknown. We conducted a multi-centre, phase-2 study testing whether prehospital titration of oxygen results in an equivalent number of patients arriving at hospital with oxygen saturations SpO2 ≥ 94%. We enrolled unconscious adults with: sustained ROSC; initial shockable rhythm; an advanced airway; and an SpO2 ≥ 95%. Initially (Sept 2015-March 2016) patients were randomised 1:1 to either 2 L/minute (L/min) oxygen (titrated) or >10 L/min oxygen (control) via a bag-valve reservoir. However, one site experienced a high number of desaturations (SpO2 < 94%) in the titrated arm and this arm was changed (April 2016) to an initial reduction of oxygen to 4 L/min then, if tolerated, to 2 L/min, and the desaturation limit was decreased to <90%. We randomised 61 patients to titrated (n = 37: 2L/min = 20 and 2-4 L/min = 17) oxygen or control (n = 24). Patients allocated to titrated oxygen were more likely to desaturate compared to controls ((SpO2 < 94%: 43% vs. 4%, p = 0.001; SpO2 < 90%: 19% vs. 4%, p = 0.09). The majority of desaturations (81%) occurred at 2L/min. On arrival at hospital the majority of patients had a SpO2 ≥ 94% (titrated: 90% vs. control: 100%) and all patients had a SpO2 ≥ 90%. One patient (control) re-arrested. Survival to hospital discharge was similar. Oxygen titration post-ROSC is feasible in the prehospital environment, but incremental titration commencing at 4L/min oxygen flow may be needed to maintain an oxygen saturation >90% (NCT02499042). Copyright © 2018 Elsevier B.V. All rights reserved.

  5. A Catalog of Photometric Redshift and the Distribution of Broad Galaxy Morphologies

    NASA Astrophysics Data System (ADS)

    Paul, Nicholas; Virag, Nicholas; Shamir, Lior

    2018-06-01

    We created a catalog of photometric redshift of ~3,000,000 SDSS galaxies annotated by their broad morphology. The photometric redshift was optimized by testing and comparing several pattern recognition algorithms and variable selection strategies, trained and tested on a subset of the galaxies in the catalog that had spectra. The galaxies in the catalog have i magnitude brighter than 18 and Petrosian radius greater than 5.5''. The majority of these objects are not included in previous SDSS photometric redshift catalogs such as the photoz table of SDSS DR12. Analysis of the catalog shows that the number of galaxies in the catalog that are visually spiral increases until redshift of ~0.085, where it peaks and starts to decrease. It also shows that the number of spiral galaxies compared to elliptical galaxies drops as the redshift increases. The catalog is publicly available at https://figshare.com/articles/Morphology_and_photometric_redshift_catalog/4833593

  6. Analysis for nickel (3 and 4) in positive plates from nickel-cadmium cells

    NASA Technical Reports Server (NTRS)

    Lewis, Harlan L.

    1994-01-01

    The NASA-Goddard procedure for destructive physical analysis (DPA) of nickel-cadmium cells contains a method for analysis of residual charged nickel as NiOOH in the positive plates at complete cell discharge, also known as nickel precharge. In the method, the Ni(III) is treated with an excess of an Fe(II) reducing agent and then back titrated with permanganate. The Ni(III) content is the difference between Fe(II) equivalents and permanganate equivalents. Problems have arisen in analysis at NAVSURFWARCENDIV, Crane because for many types of cells, particularly AA-size and some 'space-qualified' cells, zero or negative Ni(III) contents are recorded for which the manufacturer claims 3-5 percent precharge. Our approach to this problem was to reexamine the procedure for the source of error, and correct it or develop an alternative method.

  7. Misuse of thermodynamics in the interpretation of isothermal titration calorimetry data for ligand binding to proteins.

    PubMed

    Pethica, Brian A

    2015-03-01

    Isothermal titration calorimetry (ITC) has given a mass of data on the binding of small molecules to proteins and other biopolymers, with particular interest in drug binding to proteins chosen as therapeutic indicators. Interpretation of the enthalpy data usually follows an unsound protocol that uses thermodynamic relations in circumstances where they do not apply. Errors of interpretation include incomplete definitions of ligand binding and equilibrium constants and neglect of the non-ideality of the solutions under study, leading to unreliable estimates of standard free energies and entropies of binding. The mass of reported thermodynamic functions for ligand binding to proteins estimated from ITC enthalpies alone is consequently of uncertain thermodynamic significance and utility. ITC and related experiments to test the protocol assumptions are indicated. A thermodynamic procedure avoiding equilibrium constants or other reaction models and not requiring protein activities is given. The discussion draws attention to the fundamental but neglected relation between the thermodynamic activity and bioactivity of drugs and to the generally unknown thermodynamic status of ligand solutions, which for drugs relates directly to effective therapeutic dosimetry. Copyright © 2014 Elsevier Inc. All rights reserved.

  8. Development of new composite biosorbents from olive pomace wastes

    NASA Astrophysics Data System (ADS)

    Pagnanelli, Francesca; Viggi, Carolina Cruz; Toro, Luigi

    2010-06-01

    In this study olive pomace was used as a source of binding substances for the development of composite biosorbents to be used in heavy metal removal from aqueous solutions. The aim was to obtain biosorbent material with an increased concentration of binding sites. The effects of two different extraction procedures (one using only methanol and the other one hexane followed by methanol) on the binding properties of olive pomace were tested by potentiometric titrations and batch biosorption tests for copper and cadmium removal. Titration modelling evidenced that both kinds of extractions generated a solid with a reduced amount of protonatable sites. Biosorption tests were organized according to full factorial designs. Analysis of variance denoted that both kinds of extractions determined a statistically significant negative effect on metal biosorption. In the case of cadmium extractions also determined a significant decrease of selectivity with respect to olive pomace. When the acid-base and binding properties of the substances extracted were determined, they were adsorbed onto a synthetic resin (octadecylsilane) and calcium alginate beads. In this way two kinds of composite biosorbents have been obtained both having an increased concentration of binding substances with respect to native olive pomace, also working more efficiently in metal removal.

  9. 40 CFR Appendix A to Part 425 - Potassium Ferricyanide Titration Method

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Method A Appendix A to Part 425 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED... Appendix A to Part 425—Potassium Ferricyanide Titration Method Source The potassium ferricyanide titration method is based on method SLM 4/2 described in “Official Method of Analysis,” Society of Leather Trades...

  10. 40 CFR Appendix A to Part 425 - Potassium Ferricyanide Titration Method

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Method A Appendix A to Part 425 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED..., App. A Appendix A to Part 425—Potassium Ferricyanide Titration Method Source The potassium ferricyanide titration method is based on method SLM 4/2 described in “Official Method of Analysis,” Society of...

  11. 40 CFR Appendix A to Part 425 - Potassium Ferricyanide Titration Method

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Method A Appendix A to Part 425 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED... Appendix A to Part 425—Potassium Ferricyanide Titration Method Source The potassium ferricyanide titration method is based on method SLM 4/2 described in “Official Method of Analysis,” Society of Leather Trades...

  12. Ascorbic Acid as a Standard for Iodometric Titrations. An Analytical Experiment for General Chemistry

    NASA Astrophysics Data System (ADS)

    Silva, Cesar R.; Simoni, Jose A.; Collins, Carol H.; Volpe, Pedro L. O.

    1999-10-01

    Ascorbic acid is suggested as the weighable compound for the standardization of iodine solutions in an analytical experiment in general chemistry. The experiment involves an iodometric titration in which iodine reacts with ascorbic acid, oxidizing it to dehydroascorbic acid. The redox titration endpoint is determined by the first iodine excess that is complexed with starch, giving a deep blue-violet color. The results of the titration of iodine solution using ascorbic acid as a calibration standard were compared with the results acquired by the classic method using a standardized solution of sodium thiosulfate. The standardization of the iodine solution using ascorbic acid was accurate and precise, with the advantages of saving time and avoiding mistakes due to solution preparation. The colorless ascorbic acid solution gives a very clear and sharp titration end point with starch. It was shown by thermogravimetric analysis that ascorbic acid can be dried at 393 K for 2 h without decomposition. This experiment allows general chemistry students to perform an iodometric titration during a single laboratory period, determining with precision the content of vitamin C in pharmaceutical formulations.

  13. Test of CCD Precision Limits for Differential Photometry

    NASA Technical Reports Server (NTRS)

    Borucki, W. J.; Dunham, E. W.; Wei, M. Z.; Robinson, L. B.; Ford, C. H.; Granados, A. F.

    1995-01-01

    Results of tests to demonstrate the very high differential-photometric stability of CCD light sensors are presented. The measurements reported here demonstrate that in a controlled laboratory environment, a front-illuminated CCD can provide differential-photometric measurements with reproducible precision approaching one part in 105. Practical limitations to the precision of differential-photometric measurements with CCDs and implications for spaceborne applications are discussed.

  14. Modeling of Diffuse Photometric Signatures of Satellites for Space Object Identification.

    DTIC Science & Technology

    1982-12-01

    to provide the groundwork for devel- opment of a computer program which could serve as an aid to tactical space object identification and analysis ...I Photometric Analysis Capability at the ADIC. . . . . .. 2 Operational Limitations of the Photometric Data Analysis Module (PDA...7 PDAM Diffuse Analysis . . . . . . . . . . . . . . . . . 7 Real World SOI Requirements vs POAN Capabilities . . . . 16 Statement of the Problem

  15. Automatic Astrometric and Photometric Calibration with SCAMP

    NASA Astrophysics Data System (ADS)

    Bertin, E.

    2006-07-01

    Astrometric and photometric calibrations have remained the most tiresome step in the reduction of large imaging surveys. I present a new software package, SCAMP which has been written to address this problem. SCAMP efficiently computes accurate astrometric and photometric solutions for any arbitrary sequence of FITS images in a completely automatic way. SCAMP is released under the GNU General Public Licence.

  16. An Automated Analyzer System to Strengthen Teaching and Research Infrastructure at West Virginia State University

    DTIC Science & Technology

    2015-08-18

    SECURITY CLASSIFICATION OF: Arena 60 Discrete Photometric Analyzer System and ancillary instrumentation were acquired to increase our analytical...Infrastructure at West Virginia State University Report Title Arena 60 Discrete Photometric Analyzer System and ancillary instrumentation were acquired...Progress Principal Accomplishments: a. One Postdoctoral fellow was trained using the automated Arena 60 Discrete Photometric Analyzer and

  17. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Genest-Beaulieu, C.; Bergeron, P., E-mail: genest@astro.umontreal.ca, E-mail: bergeron@astro.umontreal.ca

    We present a comparative analysis of atmospheric parameters obtained with the so-called photometric and spectroscopic techniques. Photometric and spectroscopic data for 1360 DA white dwarfs from the Sloan Digital Sky Survey (SDSS) are used, as well as spectroscopic data from the Villanova White Dwarf Catalog. We first test the calibration of the ugriz photometric system by using model atmosphere fits to observed data. Our photometric analysis indicates that the ugriz photometry appears well calibrated when the SDSS to AB{sub 95} zeropoint corrections are applied. The spectroscopic analysis of the same data set reveals that the so-called high-log g problem canmore » be solved by applying published correction functions that take into account three-dimensional hydrodynamical effects. However, a comparison between the SDSS and the White Dwarf Catalog spectra also suggests that the SDSS spectra still suffer from a small calibration problem. We then compare the atmospheric parameters obtained from both fitting techniques and show that the photometric temperatures are systematically lower than those obtained from spectroscopic data. This systematic offset may be linked to the hydrogen line profiles used in the model atmospheres. We finally present the results of an analysis aimed at measuring surface gravities using photometric data only.« less

  18. Risk factors associated with treatment discontinuation and down-titration in type 2 diabetes patients treated with sulfonylureas.

    PubMed

    Iglay, Kristy; Qiu, Ying; Steve Fan, Chun-Po; Li, Zhiyi; Tang, Jackson; Laires, Pedro

    2016-09-01

    Sulfonylurea therapy among patients with type 2 diabetes mellitus (T2DM) can be disrupted due to adverse events, including hypoglycemia. A retrospective study using the MarketScan claims database quantified the frequency of sulfonylurea discontinuation or down-titration and identified associated risk factors. Adult patients with an index sulfonylurea prescription between 2008 and 2012 and 1 year continuous enrollment pre- and post-index were included. Therapy changes assessed over 1 year post-index included discontinuation and down-titration. Discontinuation occurred if the date of a fill was >90 days from the end date of the preceding fill. Down-titration occurred when a fill had a lower equivalent dose than the fill on the index date. Kaplan-Meier methods estimated the probability of either discontinuation or down-titration over 12 months, and Cox regression models identified associated risk factors. A total of 104,082 sulfonylurea users were included in the study and the probability of either discontinuation or down-titration at 3, 6 and 12 months was 23.2%, 38.9%, and 52.3%, respectively. Major risk factors associated with therapy changes included post-index hypoglycemia (discontinuation hazard ratio [HR] = 1.78 [1.68, 1.89]; down-titration HR =2.79 [2.40, 3.23]) and concomitant use of insulin (discontinuation HR =1.48 [1.40, 1.57]; down-titration HR =1.82 [1.56, 2.11]). Other risk factors included younger age, female gender, use of second generation sulfonylureas, prior cardiovascular comorbidity and liver disease. The study was not able to assess unreported, potentially mild cases of hypoglycemia, nor was it able to evaluate the association between changes in therapy and HbA1c levels or body weight. More than half of T2DM patients who initiated sulfonylurea therapy discontinued or down-titrated within 1 year. Insulin use and hypoglycemia were associated with sulfonylurea therapy change.

  19. Dose Titration of Pregabalin in Patients with Painful Diabetic Peripheral Neuropathy: Simulation Based on Observational Study Patients Enriched with Data from Randomized Studies.

    PubMed

    Alexander, Joe; Edwards, Roger A; Manca, Luigi; Grugni, Roberto; Bonfanti, Gianluca; Emir, Birol; Whalen, Edward; Watt, Stephen; Parsons, Bruce

    2018-03-01

    Achieving a therapeutic response to pregabalin in patients with painful diabetic peripheral neuropathy (pDPN) requires adequate upward dose titration. Our goal was to identify relationships between titration and response to pregabalin in patients with pDPN. Data were integrated from nine randomized, placebo-controlled clinical trials as well as one 6-week open-label observational study conducted by 5808 physicians (2642 patients with pDPN) in standard outpatient settings in Germany. These studies evaluated pregabalin for treatment of pDPN. Using these data, we examined "what if" scenarios using a microsimulation platform that integrates data from randomized and observational sources as well as autoregressive-moving-average with exogenous inputs models that predict pain outcomes, taking into account weekly changes in pain, sleep interference, dose, and other patient characteristics that were unchanging. Final pain levels were significantly different depending on dose changes (P < 0.0001), with greater proportions improving with upward titration regardless of baseline pain severity. Altogether, 78.5% of patients with pDPN had 0-1 dose change, and 15.2% had ≥ 2 dose changes. Simulation demonstrated that the 4.8% of inadequately titrated patients who did not improve/very much improve their pain levels would have benefited from ≥ 2 dose changes. Patient satisfaction with tolerability (range 90.3-96.2%) was similar, regardless of baseline pain severity, number of titrations, or extent of improvement, suggesting that tolerability did not influence treatment response patterns. Upward dose titration reduced pain in patients with pDPN who actually received it. Simulation also predicted pain reduction in an inadequately titrated nonresponder subgroup of patients had they actually received adequate titration. The decision not to uptitrate must have been driven by factors other than tolerability. Pfizer, Inc.

  20. Lacosamide and sodium channel-blocking antiepileptic drug cross-titration against levetiracetam background therapy.

    PubMed

    Baulac, M; Byrnes, W; Williams, P; Borghs, S; Webster, E; De Backer, M; Dedeken, P

    2017-04-01

    To assess prospectively the effectiveness of lacosamide (LCM) added to levetiracetam (LEV) after down-titration of a concomitant sodium channel blocker (SCB) among patients with focal epilepsy not adequately controlled on LEV and SCB. In this open-label trial, LCM was initiated at 100 mg/day and up-titrated to 200-600 mg/day over 9 weeks; SCB down-titration started when LCM dose reached 200 mg/day. Patients remained on stable LCM/LEV doses for 12 weeks' maintenance (21-week treatment period). The primary outcome was retention rate on LCM. Due to recruitment challenges, fewer than the planned 300 patients participated in the trial, resulting in the trial being underpowered. Overall, 120 patients (mean age 39.7 years) started and 93 completed the trial. The most frequently used SCBs were lamotrigine (39.2%), carbamazepine (30.8%) and oxcarbazepine (27.5%). Eighty-four patients adhered to protocol and discontinued their SCB after cross-titration, but there was insufficient evidence for 36 patients. Retention rate was 73.3% (88/120) for all patients and 83.3% (70/84) for those with evidence of SCB discontinuation. Seizure freedom for patients completing maintenance was 14.0% (13/93). Discontinuation due to adverse events (6.7%) and lack of efficacy (3.3%) occurred primarily during cross-titration. Most frequently reported adverse events during treatment were dizziness (23.3%), headache (15.0%) and fatigue (8.3%). In patients with uncontrolled seizures on LEV/SCB, the LCM/LEV combination appeared to be effective and well tolerated. A cross-titration schedule-flexible LCM up-titration, concomitant SCB down-titration and stable background LEV-could present a feasible and practical approach to initiating LCM while minimizing pharmacodynamic interactions with a SCB. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  1. Biological Evaluation of Methods for the Determination of Free Available Chlorine.

    DTIC Science & Technology

    1980-03-01

    tri • :., t at pH 6.0, 20’C. Lowest C1 level for false positive, mg/l Chloramine Species Test NH2CI NHC1 2 NCI1 DPDT 4.8 b 0.8 DPDTSF 4.8 b 0.6 DPDP 1.1...Available Chlorine Chlorine Membrane Electrode T )PD FACTS biofac Amperometric titration 20. ASIST’IACT C’ntAtmoe so &eJie .b f nerandm Idenwlry by block...methods tested yielded false positive determinations of free chlorine with one or more of the inorganic chloramines . The FACTS procedure was the most

  2. Radiocarbon tracer measurements of atmospheric hydroxyl radical concentrations

    NASA Technical Reports Server (NTRS)

    Campbell, M. J.; Farmer, J. C.; Fitzner, C. A.; Henry, M. N.; Sheppard, J. C.

    1986-01-01

    The usefulness of the C-14 tracer in measurements of atmospheric hydroxyl radical concentration is discussed. The apparatus and the experimental conditions of three variations of a radiochemical method of atmosphere analysis are described and analyzed: the Teflon bag static reactor, the flow reactor (used in the Wallops Island tests), and the aircraft OH titration reactor. The procedure for reduction of the aircraft reactor instrument data is outlined. The problems connected with the measurement of hydroxyl radicals are discussed. It is suggested that the gas-phase radioisotope methods have considerable potential in measuring tropospheric impurities present in very low concentrations.

  3. Insights into energy delivery to myocardial tissue during radiofrequency ablation through application of the first law of thermodynamics.

    PubMed

    Bunch, T Jared; Day, John D; Packer, Douglas L

    2009-04-01

    The approach to catheter-based radiofrequency ablation of atrial fibrillation has evolved, and as a consequence, more energy is delivered in the posterior left atrium, exposing neighboring tissue to untoward thermal injury. Simultaneously, catheter technology has advanced to allow more efficient energy delivery into the myocardium, which compounds the likelihood of collateral injury. This review focuses on the basic principles of thermodynamics as they apply to energy delivery during radiofrequency ablation. These principles can be used to titrate energy delivery and plan ablative approaches in an effort to minimize complications during the procedure.

  4. Pulsating potentiometric titration technique for assay of dissolved oxygen in water at trace level.

    PubMed

    Sahoo, P; Ananthanarayanan, R; Malathi, N; Rajiniganth, M P; Murali, N; Swaminathan, P

    2010-06-11

    A simple but high performance potentiometric titration technique using pulsating sensors has been developed for assay of dissolved oxygen (DO) in water samples down to 10.0 microg L(-1) levels. The technique involves Winkler titration chemistry, commonly used for determination of dissolved oxygen in water at mg L(-1) levels, with modification in methodology for accurate detection of end point even at 10.0 microg L(-1) levels DO present in the sample. An indigenously built sampling cum pretreatment vessel has been deployed for collection and chemical fixing of dissolved oxygen in water samples from flowing water line without exposure to air. A potentiometric titration facility using pulsating sensors developed in-house is used to carry out titration. The power of the titration technique has been realised in estimation of very dilute solution of iodine equivalent to 10 microg L(-1) O(2). Finally, several water samples containing dissolved oxygen from mg L(-1) to microg L(-1) levels were successfully analysed with excellent reproducibility using this new technique. The precision in measurement of DO in water at 10 microg L(-1) O(2) level is 0.14 (n=5), RSD: 1.4%. Probably for the first time a potentiometric titration technique has been successfully deployed for assay of dissolved oxygen in water samples at 10 microg L(-1) levels. Copyright 2010 Elsevier B.V. All rights reserved.

  5. Quantitative Analysis of Sulfate in Water by Indirect EDTA Titration

    ERIC Educational Resources Information Center

    Belle-Oudry, Deirdre

    2008-01-01

    The determination of sulfate concentration in water by indirect EDTA titration is an instructive experiment that is easily implemented in an analytical chemistry laboratory course. A water sample is treated with excess barium chloride to precipitate sulfate ions as BaSO[subscript 4](s). The unprecipitated barium ions are then titrated with EDTA.…

  6. The Quantitative Resolution of a Mixture of Group II Metal Ions by Thermometric Titration with EDTA. An Analytical Chemistry Experiment.

    ERIC Educational Resources Information Center

    Smith, Robert L.; Popham, Ronald E.

    1983-01-01

    Presents an experiment in thermometric titration used in an analytic chemistry-chemical instrumentation course, consisting of two titrations, one a mixture of calcium and magnesium, the other of calcium, magnesium, and barium ions. Provides equipment and solutions list/specifications, graphs, and discussion of results. (JM)

  7. Microscale pH Titrations Using an Automatic Pipet.

    ERIC Educational Resources Information Center

    Flint, Edward B.; Kortz, Carrie L.; Taylor, Max A.

    2002-01-01

    Presents a microscale pH titration technique that utilizes an automatic pipet. A small aliquot (1-5 mL) of the analyte solution is titrated with repeated additions of titrant, and the pH is determined after each delivery. The equivalence point is determined graphically by either the second derivative method or a Gran plot. The pipet can be…

  8. Acid-base titrations for polyacids: Significance of the pK sub a and parameters in the Kern equation

    NASA Technical Reports Server (NTRS)

    Meites, L.

    1978-01-01

    A new method is suggested for calculating the dissociation constants of polyvalent acids, especially polymeric acids. In qualitative form the most significant characteristics of the titration curves are demonstrated and identified which are obtained when titrating the solutions of such acids with a standard base potentiometrically.

  9. Test of CCD Precision Limits for Differential Photometry

    NASA Technical Reports Server (NTRS)

    Robinson, L. B.; Wei, M. Z.; Borucki, W. J.; Dunham, E. W.; Ford, C. H.; Granados, A. F.

    1995-01-01

    Results of tests to demonstrate the very high differential-photometric stability of CCD light sensors are presented. The measurements reported here demonstrate that in a controlled laboratory environment, a front-illuminated CCD can provide differential-photometric measurements with reproducible precision approaching one part in 10(exp 5). Practical limitations to the precision of differential-photometric measurements with CCDs and implications for spaceborne applications are discussed.

  10. Improving medication titration in heart failure by embedding a structured medication titration plan.

    PubMed

    Hickey, Annabel; Suna, Jessica; Marquart, Louise; Denaro, Charles; Javorsky, George; Munns, Andrew; Mudge, Alison; Atherton, John J

    2016-12-01

    To improve up-titration of medications to target dose in heart failure patients by improving communication from hospital to primary care. This quality improvement project was undertaken within three heart failure disease management (HFDM) services in Queensland, Australia. A structured medication plan was collaboratively designed and implemented in an iterative manner, using methods including awareness raising and education, audit and feedback, integration into existing work practice, and incentive payments. Evaluation was undertaken using sequential audits, and included process measures (use of the titration plan, assignment of responsibility) and outcome measures (proportion of patients achieving target dose) in HFDM service patients with reduced left ventricular ejection fraction. Comparison of the three patient cohorts (pre-intervention cohort A n=96, intervention cohort B n=95, intervention cohort C n=89) showed increase use of the titration plan, a shift to greater primary care responsibility for titration, and an increase in the proportion of patients achieving target doses of angiotensin converting enzyme inhibitors/angiotensin receptor blockers (ACEI/ARB) (A 37% vs B 48% vs C 55%, p=0.051) and beta-blockers (A 38% vs B 33% vs C 51%, p=0.045). Combining all three cohorts, patients not on target doses when discharged from hospital were more likely to achieve target doses of ACEI/ARB (p<0.0001) and beta blockers (p<0.0001) within six months if they received a medication titration plan. A medication titration plan was successfully implemented in three HFDM services and improved transitional communication and achievement of target doses of evidence-based therapies within six months of hospital discharge. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  11. Does a patient-managed insulin intensification strategy with insulin glargine and insulin glulisine provide similar glycemic control as a physician-managed strategy? Results of the START (Self-Titration With Apidra to Reach Target) Study: a randomized noninferiority trial.

    PubMed

    Harris, Stewart B; Yale, Jean-François; Berard, Lori; Stewart, John; Abbaszadeh, Babak; Webster-Bogaert, Susan; Gerstein, Hertzel C

    2014-01-01

    OBJECTIVE Diabetes self-management is universally regarded as a foundation of diabetes care. We determined whether comparable glycemic control could be achieved by self-titration versus physician titration of a once-daily bolus insulin dose in patients with type 2 diabetes who are unable to achieve optimal glycemia control with a basal insulin. RESEARCH DESIGN AND METHODS Patients with type 2 diabetes, an HbA1c level >7% (53 mmol/mol), and either nocturnal hypoglycemia episodes or an insufficient basal insulin glargine level (with or without oral agents) to achieve a fasting plasma glucose level ≤6 mmol/L (108 mg/dL) were studied. Participants all had bolus insulin glulisine added at breakfast and were allocated to either algorithm-guided patient self-titration or physician titration. The primary outcome was an HbA1c level ≤7% (53 mmol/mol) without severe hypoglycemia. RESULTS After a mean (SD) follow-up of 159.4 days (36.2 days), 28.4% of participants in the self-titration arm vs. 21.2% in the physician titration arm achieved an HbA1c level of ≤7% (53 mmol/mol) without severe hypoglycemia (between-group absolute difference 7.2%; 95% CI -3.2 to 17.7). The lower end of this 95% confidence interval was within the predetermined noninferiority boundary of -5% (P noninferiority = 0.011). CONCLUSIONS In stable patients with type 2 diabetes who are receiving doses of basal insulin glargine who require bolus insulin, a simple bolus insulin patient-managed titration algorithm is as effective as a physician-managed algorithm.

  12. Rapid clozapine titration in treatment-refractory bipolar disorder.

    PubMed

    Ifteni, Petru; Correll, Christoph U; Nielsen, Jimmi; Burtea, Victoria; Kane, John M; Manu, Peter

    2014-09-01

    Clozapine is effective in treatment-refractory bipolar disorder (BD). Guidelines recommend slow titration to prevent seizures, hypotension and myocarditis, but this stance is not supported by comparative data. To evaluate the safety and effectiveness of rapid clozapine titration in BD. Analysis of a consecutive cohort of treatment-refractory BD patients with mixed/manic episode admitted on alternate days to one of two units of a psychiatric hospital. On one unit, clozapine was started at 25mg followed by 25-50mg as needed every 6h (maximum=100mg/day) on day 1, followed by increases of 25-100mg/day. On the other unit, clozapine was initiated with 25mg in day 1, followed by increases of 25-50mg/day. The primary outcome was the number of days from starting clozapine until readiness for discharge, adjusted in logistic regression for the number of antipsychotics tried during the hospitalization, psychotropic co-treatments and presence of psychotic features. Patients subject to rapid (N=44) and standard (N=23) titration were similar in age, gender, smoking status, body mass index, illness severity at baseline and discharge, and highest clozapine dose. Clozapine was discontinued due to hypotension (N=1) and pneumonia (N=1) during rapid titration, and for excessive sedation (N=1) in each titration group. The number of hospital days from starting clozapine until readiness for discharge was 3.8 days shorter in the rapid titration group (12.7±6.3 vs. 16.5±5.8, p=0.0077). Rapid clozapine titration appeared safe and effective for treatment-refractory BD. The potential for shorter hospital stays justifies prospective trials of this method. Copyright © 2014 Elsevier B.V. All rights reserved.

  13. Clinical, polysomnographic, and CPAP titration features of obstructive sleep apnea: Mixed versus purely obstructive type.

    PubMed

    Lee, Sang-Ahm; Lee, Gha-Hyun; Chung, Yoo-Sam; Kim, Woo Sung

    2015-08-15

    To determine whether obstructive sleep apnea syndrome (OSAS) patients with mixed sleep apnea (MSA) have different clinical, polysomnographic, and continuous positive airway pressure (CPAP) titration findings compared to OSAS patients without MSA. We retrospectively reviewed the records of OSAS patients who had undergone CPAP titration and categorized them into pure-OSA and mixed-OSA groups. Demographic features, daytime sleepiness, and apnea severity were compared between the two groups using univariate and multivariate analyses. CPAP titration findings were also compared between the two groups. One hundred and ninety-five subjects (n=126 pure-OSA; n=69 mixed-OSA) were included in the analysis. Compared to the pure-OSA group, the mixed-OSA group had a higher percentage of males (p=0.003) and a higher body mass index (p=0.044), Epworth Sleepiness Scale score (p=0.028), and apnea-hypopnea index (AHI) (p<0.001). In logistic regression analysis, older age, male sex, and higher body mass index were independently associated with mixed-OSA before PSG study. When using AHI as a covariable, the higher AHI with older age, male sex, and daytime sleepiness was independently related to mixed-OSA. The mixed-OSA group had a higher percentage of patients with complex sleep apnea, a lower percentage of patients with optimal titration, and a higher titrated pressure than the pure-OSA group. Severe OSA, older age, male sex, obesity, and daytime sleepiness were related to mixed-OSA. Complex sleep apnea, less optimal titration, and a higher titrated CPAP were also associated with MSA in OSAS patients. Copyright © 2015 Elsevier B.V. All rights reserved.

  14. Fluorometric titration approach for calibration of quantity of binding site of purified monoclonal antibody recognizing epitope/hapten nonfluorescent at 340 nm.

    PubMed

    Yang, Xiaolan; Hu, Xiaolei; Xu, Bangtian; Wang, Xin; Qin, Jialin; He, Chenxiong; Xie, Yanling; Li, Yuanli; Liu, Lin; Liao, Fei

    2014-06-17

    A fluorometric titration approach was proposed for the calibration of the quantity of monoclonal antibody (mcAb) via the quench of fluorescence of tryptophan residues. It applied to purified mcAbs recognizing tryptophan-deficient epitopes, haptens nonfluorescent at 340 nm under the excitation at 280 nm, or fluorescent haptens bearing excitation valleys nearby 280 nm and excitation peaks nearby 340 nm to serve as Förster-resonance-energy-transfer (FRET) acceptors of tryptophan. Titration probes were epitopes/haptens themselves or conjugates of nonfluorescent haptens or tryptophan-deficient epitopes with FRET acceptors of tryptophan. Under the excitation at 280 nm, titration curves were recorded as fluorescence specific for the FRET acceptors or for mcAbs at 340 nm. To quantify the binding site of a mcAb, a universal model considering both static and dynamic quench by either type of probes was proposed for fitting to the titration curve. This was easy for fitting to fluorescence specific for the FRET acceptors but encountered nonconvergence for fitting to fluorescence of mcAbs at 340 nm. As a solution, (a) the maximum of the absolute values of first-order derivatives of a titration curve as fluorescence at 340 nm was estimated from the best-fit model for a probe level of zero, and (b) molar quantity of the binding site of the mcAb was estimated via consecutive fitting to the same titration curve by utilizing such a maximum as an approximate of the slope for linear response of fluorescence at 340 nm to quantities of the mcAb. This fluorometric titration approach was proved effective with one mcAb for six-histidine and another for penicillin G.

  15. Titration ELISA as a Method to Determine the Dissociation Constant of Receptor Ligand Interaction.

    PubMed

    Eble, Johannes A

    2018-02-15

    The dissociation constant describes the interaction between two partners in the binding equilibrium and is a measure of their affinity. It is a crucial parameter to compare different ligands, e.g., competitive inhibitors, protein isoforms and mutants, for their binding strength to a binding partner. Dissociation constants are determined by plotting concentrations of bound versus free ligand as binding curves. In contrast, titration curves, in which a signal that is proportional to the concentration of bound ligand is plotted against the total concentration of added ligand, are much easier to record. The signal can be detected spectroscopically and by enzyme-linked immunosorbent assay (ELISA). This is exemplified in a protocol for a titration ELISA that measures the binding of the snake venom-derived rhodocetin to its immobilized target domain of α2β1 integrin. Titration ELISAs are versatile and widely used. Any pair of interacting proteins can be used as immobilized receptor and soluble ligand, provided that both proteins are pure, and their concentrations are known. The difficulty so far has been to determine the dissociation constant from a titration curve. In this study, a mathematical function underlying titration curves is introduced. Without any error-prone graphical estimation of a saturation yield, this algorithm allows processing of the raw data (signal intensities at different concentrations of added ligand) directly by mathematical evaluation via non-linear regression. Thus, several titration curves can be recorded simultaneously and transformed into a set of characteristic parameters, among them the dissociation constant and the concentration of binding-active receptor, and they can be evaluated statistically. When combined with this algorithm, titration ELISAs gain the advantage of directly presenting the dissociation constant. Therefore, they may be used more efficiently in the future.

  16. Delay Discounting in Lewis and Fischer 344 Rats: Steady-state and Rapid-determination Adjusting-amount Procedures

    PubMed Central

    Stein, Jeffrey S; Pinkston, Jonathan W; Brewer, Adam T; Francisco, Monica T; Madden, Gregory J

    2012-01-01

    Lewis rats have been shown to make more impulsive choices than Fischer 344 rats in discrete-trial choice procedures that arrange fixed (i.e., nontitrating) reinforcement parameters. However, nontitrating procedures yield only gross estimates of preference, as choice measures in animal subjects are rarely graded at the level of the individual subject. The present study was designed to examine potential strain differences in delay discounting using an adjusting-amount procedure, in which distributed (rather than exclusive) choice is observed due to dynamic titration of reinforcer magnitude across trials. Using a steady-state version of the adjusting-amount procedure in which delay was manipulated between experimental conditions, steeper delay discounting was observed in Lewis rats compared to Fischer 344 rats; further, delay discounting in both strains was well described by the traditional hyperbolic discounting model. However, upon partial completion of the present study, a study published elsewhere (Wilhelm & Mitchell, 2009) demonstrated no difference in delay discounting between these strains with the use of a more rapid version of the adjusting-amount procedure (i.e., in which delay is manipulated daily). Thus, following completion of the steady-state assessment in the present study, all surviving Lewis and Fischer 344 rats completed an approximation of this rapid-determination procedure in which no strain difference in delay discounting was observed. PMID:22693360

  17. Delay discounting in Lewis and Fischer 344 rats: steady-state and rapid-determination adjusting-amount procedures.

    PubMed

    Stein, Jeffrey S; Pinkston, Jonathan W; Brewer, Adam T; Francisco, Monica T; Madden, Gregory J

    2012-05-01

    Lewis rats have been shown to make more impulsive choices than Fischer 344 rats in discrete-trial choice procedures that arrange fixed (i.e., nontitrating) reinforcement parameters. However, nontitrating procedures yield only gross estimates of preference, as choice measures in animal subjects are rarely graded at the level of the individual subject. The present study was designed to examine potential strain differences in delay discounting using an adjusting-amount procedure, in which distributed (rather than exclusive) choice is observed due to dynamic titration of reinforcer magnitude across trials. Using a steady-state version of the adjusting-amount procedure in which delay was manipulated between experimental conditions, steeper delay discounting was observed in Lewis rats compared to Fischer 344 rats; further, delay discounting in both strains was well described by the traditional hyperbolic discounting model. However, upon partial completion of the present study, a study published elsewhere (Wilhelm & Mitchell, 2009) demonstrated no difference in delay discounting between these strains with the use of a more rapid version of the adjusting-amount procedure (i.e., in which delay is manipulated daily). Thus, following completion of the steady-state assessment in the present study, all surviving Lewis and Fischer 344 rats completed an approximation of this rapid-determination procedure in which no strain difference in delay discounting was observed.

  18. Determination of the titratable acidity and the pH of wine based on potentiometric flow injection analysis.

    PubMed

    Vahl, Katja; Kahlert, Heike; von Mühlen, Lisandro; Albrecht, Anja; Meyer, Gabriele; Behnert, Jürgen

    2013-07-15

    A FIA system using a pH-sensitive detector based on a graphite/quinhydrone/silicone composite electrode was applied to determine sequentially the titratable acidity and the pH of wine, as well as the sum of calcium and magnesium ions. For all measurements the same FIA configuration was used employing different carrier solutions. The results for the determination of acidity and pH are in good agreement with those obtained by classical potentiometric titrations and by pH measurements using a conventional glass electrode. The standard deviation was less than 1.5% for both kinds of measurements and the sample volume was 150 μL. The method allows about 40 determinations of titratable acidity per hour and 30 pH measurements per hour. The titration method can be adjusted to the legal requirements in USA and Europe. Copyright © 2013 Elsevier B.V. All rights reserved.

  19. UBVRI PHOTOMETRIC STANDARD STARS AROUND THE CELESTIAL EQUATOR: UPDATES AND ADDITIONS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Landolt, Arlo U.

    2009-05-15

    New broadband UBVRI photoelectric observations on the Johnson-Kron-Cousins photometric system have been made of 202 stars around the sky, and centered at the celestial equator. These stars constitute both an update of and additions to a previously published list of equatorial photometric standard stars. The list is capable of providing, for both celestial hemispheres, an internally consistent homogeneous broadband standard photometric system around the sky. When these new measurements are included with those previously published by Landolt (1992), the entire list of standard stars in this paper encompasses the magnitude range 8.90 < V < 16.30, and the color indexmore » range -0.35 < (B - V) < +2.30.« less

  20. Systematic search for UV-excess quasar candidates in 40 square degrees at the North Galactic Pole.

    NASA Astrophysics Data System (ADS)

    Moreau, O.; Reboul, H.

    1995-05-01

    We have developed a procedure (so called PAPA) for measurement of magnitudes (about 0.1mag accurate) and positions (with accuracy better than 0.5arcsec) of all the objects present on photographic plates digitised with the MAMA machine. This homogeneous procedure was applied to four Schmidt plates - in U, B and twice V - covering the Palomar-Sky-Survey field PS +30deg 13h00m, a 40-square-degree zone at the North Galactic Pole. A general-interest exhaustive tricolour catalogue of 19542 star-like objects down to V=20.0 has been produced and we selected 1681 quasar candidates on the basis of ultraviolet excess and, when possible, absence of any measurable proper motion. The astrometric and photometric catalogue of the candidates is given in electronic form. A first multi-object spectroscopy of a few candidates confirms validity of the selection.

  1. A Laser-Pointer-Based Spectrometer for Endpoint Detection of EDTA Titrations

    ERIC Educational Resources Information Center

    Dahm, Christopher E.; Hall, James W.; Mattioni, Brian E.

    2004-01-01

    A laser spectrometer for the ethylenediaminetetra-acetic acid (EDTA) titration of magnesium or calcium ions that is designed around a handheld laser pointer as the source and a photoresistor as the detector is developed. Findings show that the use of the spectrometer reduces the degree of uncertainty and error in one part of the EDTA titrations,…

  2. Influence of kinetics on the determination of the surface reactivity of oxide suspensions by acid-base titration.

    PubMed

    Duc, M; Adekola, F; Lefèvre, G; Fédoroff, M

    2006-11-01

    The effect of acid-base titration protocol and speed on pH measurement and surface charge calculation was studied on suspensions of gamma-alumina, hematite, goethite, and silica, whose size and porosity have been well characterized. The titration protocol has an important effect on surface charge calculation as well as on acid-base constants obtained by fitting of the titration curves. Variations of pH versus time after addition of acid or base to the suspension were interpreted as diffusion processes. Resulting apparent diffusion coefficients depend on the nature of the oxide and on its porosity.

  3. Creation of a Unified Set of Core-Collapse Supernovae for Training of Photometric Classifiers

    NASA Astrophysics Data System (ADS)

    D'Arcy Kenworthy, William; Scolnic, Daniel; Kessler, Richard

    2017-01-01

    One of the key tasks for future supernova cosmology analyses is to photometrically distinguish type Ia supernovae (SNe) from their core collapse (CC) counterparts. In order to train programs for this purpose, it is necessary to train on a large number of core-collapse SNe. However, there are only a handful used for current programs. We plan to use the large amount of CC lightcurves available on the Open Supernova Catalog (OSC). Since this data is scraped from many different surveys, it is given in a number of photometric systems with different calibration and filters. We therefore created a program to fit smooth lightcurves (as a function of time) to photometric observations of arbitrary SNe. The Supercal method is then used to translate the smoothed lightcurves to a single photometric system. We can thus compile a training set of 782 supernovae, of which 127 are not type Ia. These smoothed lightcurves are also being contributed upstream to the OSC as derived data.

  4. Clustering redshift distributions for the Dark Energy Survey

    NASA Astrophysics Data System (ADS)

    Helsby, Jennifer

    Accurate determination of photometric redshifts and their errors is critical for large scale structure and weak lensing studies for constraining cosmology from deep, wide imaging surveys. Current photometric redshift methods suffer from bias and scatter due to incomplete training sets. Exploiting the clustering between a sample of galaxies for which we have spectroscopic redshifts and a sample of galaxies for which the redshifts are unknown can allow us to reconstruct the true redshift distribution of the unknown sample. Here we use this method in both simulations and early data from the Dark Energy Survey (DES) to determine the true redshift distributions of galaxies in photometric redshift bins. We find that cross-correlating with the spectroscopic samples currently used for training provides a useful test of photometric redshifts and provides reliable estimates of the true redshift distribution in a photometric redshift bin. We discuss the use of the cross-correlation method in validating template- or learning-based approaches to redshift estimation and its future use in Stage IV surveys.

  5. 3D-optical measurement system using a new vignetting aperture procedure

    NASA Astrophysics Data System (ADS)

    Hofbauer, Engelbert; Rascher, Rolf; Wühr, Konrad; Friedke, Felix; Stubenrauch, Thomas; Pastötter, Benjamin; Schleich, Sebastian; Zöcke, Christine

    2014-05-01

    A newly developed measuring procedure uses vignetting to evaluate angles and angle changes, independently from the measurement distance. Further on, the same procedure enables the transmission of a digital readout and therefore a better automation of the electronic signal evaluation, for use as an alignment telescope. The fully extended readout by a simple 3-D reflector will provide the user with a measurement result with six degrees of freedom. The vignetting field stop procedure will be described. Firstly, considering artificial vignetting, the theoretical basics from geometric-optical view are represented. Secondly, the natural vignetting with photometric effects will be considered. The distribution of intensity in the image plane light spot, the so-called V-SPOT, is analytically deduced as a function of differently measured variables. Intensity shifts within the V-Spot are examined independently from different effects by numeric simulation. On these basics, the theoretical research regarding accuracy, linearity as well as results in 2 dimensional surface reconstruction on precision optical mirrors and also three dimensional measurements in mechanical engineering are examined. Effects and deviations will be discussed. The project WiPoVi is sponsored by "Ingenieur Nachwuchs - Qualifizierung von Ingenieurnachwuchs an Fachhochschulen" by Bavarian State Ministry of Education, Science and the Arts.

  6. Simultaneous Photometric and Spectroscopic Solution for AW Cam

    NASA Astrophysics Data System (ADS)

    Frey, J. R.; Angione, R. J.; Sievers, J. R.

    2010-07-01

    We present the first four color Stromgren uvby photometric observations of the eclipsing binary system AW Cam along with the first simultaneous photometric and spectroscopic solution. This solution produced a detached system with a mass ratio of 0.45 consisting of an A1 primary and an F8 secondary, both in the main sequence band. The Hipparcos/Tycho Catalogue gives V = 8.24 and a parallax = 2.17 mas.

  7. Astronomical Research Institute Photometric Results

    NASA Astrophysics Data System (ADS)

    Linder, Tyler R.; Sampson, Ryan; Holmes, Robert

    2013-01-01

    The Astronomical Research Institute (ARI) conducts astrometric and photometric studies of asteroids with a concentration on near-Earth objects (NEOs). A 0.76-m autoscope was used for photometric studies of seven asteroids of which two were main-belt targets and five were NEOs, including one potentially hazardous asteroid (PHA). These objects are: 3122 Florence, 3960 Chaliubieju, 5143 Heracles, (6455) 1992 HE, (36284) 2000 DM8, (62128) 2000 SO1, and 2010 LF86.

  8. Light-emitting device test systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McCord, Mark; Brodie, Alan; George, James

    Light-emitting devices, such as LEDs, are tested using a photometric unit. The photometric unit, which may be an integrating sphere, can measure flux, color, or other properties of the devices. The photometric unit may have a single port or both an inlet and outlet. Light loss through the port, inlet, or outlet can be reduced or calibrated for. These testing systems can provide increased reliability, improved throughput, and/or improved measurement accuracy.

  9. Photometric Flux in EXONEST

    NASA Astrophysics Data System (ADS)

    Young, Steven K.

    As a planet orbits its parent star, the amount of light that reaches Earth from that system is dependent on the dynamics of that star system. Known as photometric variations, these slight changes in light flux are detectable by the Kepler Space Telescope and must be fully understood in order to properly model the system. There are four main factors that contribute to the photometric flux: reflected light from the planet, thermal emissions from the planet, doppler boosting in the light being emitted by the star, and ellipsoidal variations in the star. The total observed flux from each contribution then determines how much light will be seen from the star system to be used for analysis. Previous studies have normalized the photometric variation fluxes by the observed flux emitted from the star. However, normalizing data inherently and unphysically skews the result which must then be taken into account. Additionally, when the stellar flux is an unknown it is impossible to normalize the photometric variation fluxes with respect to it. This paper will preliminarily attempt to improve upon the existing studies by removing the source of the deviation for the flux results, i.e. the stellar flux. The fluxes found from each photometric variation factor will then be incorporated into EXONEST, an algorithm using Bayesian inference, that will be implemented for characterizing extrasolar systems.

  10. Weather on Other Worlds. IV. Hα Emission and Photometric Variability Are Not Correlated in L0–T8 Dwarfs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Miles-Páez, Paulo A.; Metchev, Stanimir A.; Heinze, Aren

    Recent photometric studies have revealed that surface spots that produce flux variations are present on virtually all L and T dwarfs. Their likely magnetic or dusty nature has been a much-debated problem, the resolution to which has been hindered by paucity of diagnostic multi-wavelength observations. To test for a correlation between magnetic activity and photometric variability, we searched for H α emission among eight L3–T2 ultra-cool dwarfs with extensive previous photometric monitoring, some of which are known to be variable at 3.6 μ m or 4.5 μ m. We detected H α only in the non-variable T2 dwarf 2MASS J12545393−0122474.more » The remaining seven objects do not show H α emission, even though six of them are known to vary photometrically. Combining our results with those for 86 other L and T dwarfs from the literature show that the detection rate of H α emission is very high (94%) for spectral types between L0 and L3.5 and much smaller (20%) for spectral types ≥L4, while the detection rate of photometric variability is approximately constant (30%–55%) from L0 to T8 dwarfs. We conclude that chromospheric activity, as evidenced by H α emission, and large-amplitude photometric variability are not correlated. Consequently, dust clouds are the dominant driver of the observed variability of ultra-cool dwarfs at spectral types, at least as early as L0.« less

  11. Photometric Redshifts with the LSST: Evaluating Survey Observing Strategies

    NASA Astrophysics Data System (ADS)

    Graham, Melissa L.; Connolly, Andrew J.; Ivezić, Željko; Schmidt, Samuel J.; Jones, R. Lynne; Jurić, Mario; Daniel, Scott F.; Yoachim, Peter

    2018-01-01

    In this paper we present and characterize a nearest-neighbors color-matching photometric redshift estimator that features a direct relationship between the precision and accuracy of the input magnitudes and the output photometric redshifts. This aspect makes our estimator an ideal tool for evaluating the impact of changes to LSST survey parameters that affect the measurement errors of the photometry, which is the main motivation of our work (i.e., it is not intended to provide the “best” photometric redshifts for LSST data). We show how the photometric redshifts will improve with time over the 10 year LSST survey and confirm that the nominal distribution of visits per filter provides the most accurate photo-z results. The LSST survey strategy naturally produces observations over a range of airmass, which offers the opportunity of using an SED- and z-dependent atmospheric affect on the observed photometry as a color-independent redshift indicator. We show that measuring this airmass effect and including it as a prior has the potential to improve the photometric redshifts and can ameliorate extreme outliers, but that it will only be adequately measured for the brightest galaxies, which limits its overall impact on LSST photometric redshifts. We furthermore demonstrate how this airmass effect can induce a bias in the photo-z results, and caution against survey strategies that prioritize high-airmass observations for the purpose of improving this prior. Ultimately, we intend for this work to serve as a guide for the expectations and preparations of the LSST science community with regard to the minimum quality of photo-z as the survey progresses.

  12. Determination of the intrinsic redox potentials of FeS centers of respiratory complex I from experimental titration curves

    PubMed Central

    Medvedev, Emile S.; Couch, Vernon A.

    2014-01-01

    Recently, Euro et al. [Biochem. 47, 3185 (2008)] have reported titration data for seven of nine FeS redox centers of complex I from E. coli. There is a significant uncertainty in the assignment of the titration data. Four of the titration curves were assigned to N1a, N1b, N6b, and N2 centers; one curve either to N3 or N7; one more either to N4 or N5; and the last one denoted Nx could not be assigned at all. In addition, the assignment of the titration data to N6b/N6a pair is also uncertain. In this paper, using our calculated interaction energies [Couch et al. BBA 1787, 1266 (2009)], we perform statistical analysis of these data, considering a variety of possible assignments, find the best fit, and determine the intrinsic redox potentials of the centers. The intrinsic potentials could be determined with uncertainty of less than ±10 mV at 95% confidence level for best fit assignments. We also find that the best agreement between theoretical and experimental titration curves is obtained with the N6b-N2 interaction equal to 71±14 or 96±26 mV depending on the N6b/N6a titration data assignment, which is stronger than was expected and may indicate a close distance of N2 center to the membrane surface. PMID:20513348

  13. Treatment discontinuation and tolerability as a function of dose and titration of duloxetine in the treatment of major depressive disorder.

    PubMed

    Harada, Eiji; Shirakawa, Osamu; Satoi, Yoichi; Marangell, Lauren B; Escobar, Rodrigo

    2016-01-01

    We sought to better understand how dose and titration with duloxetine treatment may impact tolerability and treatment discontinuation in patients with major depressive disorder. We investigated Phase III duloxetine trials. Group 1 was a single placebo-controlled study with a 20 mg initial dose and a slow titration to 40 and 60 mg. Group 2 was a single study with a 40 mg initial dose and final "active" doses of 40 and 60 mg (5 mg control group), with 1-week titration. Group 3 consisted of eight placebo-controlled studies with starting doses of 40, 60, and 80 mg/day with minimal titration (final dose 40-120 mg/day). Tolerability was measured by rate of discontinuation due to adverse events (DCAE). The DCAE in Group 1 were 3.6% in the 60 mg group, 3.3% in the 40 mg group, and 3.2% in the placebo group. In Group 2, the DCAE were 15.0% in the 60 mg group, 8.1% in the 40 mg group, and 4.9% in the 5 mg group. In Group 3, the DCAE were 9.7% and 4.2% in the duloxetine and placebo groups, respectively. This study suggests that starting dose and titration may have impacted tolerability and treatment discontinuation. A lower starting dose of duloxetine and slower titration may contribute to improving treatment tolerability for patients with major depressive disorder.

  14. Dose titration of repaglinide in patients with inadequately controlled type 2 diabetes.

    PubMed

    Kølendorf, Klaus; Eriksson, Johan; Birkeland, Kåre I; Kjellström, Thomas; Hreidarsson, Astradur B

    2004-04-01

    A total of 385 drug-therapy naïve patients, with inadequately controlled type 2 diabetes, were randomised into a multinational, parallel-group study to compare two strategies for dose titration of the oral hypoglycaemic agent repaglinide. Patients were allocated to either a fasting blood glucose (FBG) monitoring group with titration target 4.4-6.1 mmol/l or to a post-prandial blood glucose (PPBG) monitoring group with titration target 4.4-8.0 mmol/l. An initial titration period of up to 8 weeks was followed by a 12-week treatment period. Glycaemic control and hypoglycaemic outcomes were compared for the respective groups. HbA(1c) decreased significantly more in the FBG monitoring group by a mean of 1.38% compared to the PPBG group by a mean of 1.22% (P=0.03). The glycaemic control targets were met by fewer patients in the FBG group than in the PPBG group (57% versus 86% (P<0.001)) despite a higher mean dose of repaglinide in the FBG group. The within-patient blood glucose variability was significantly lower in the FBG group than in the PPBG group (P<0.001). In conclusion, repaglinide lowered the HbA(1c) effectively and safely in both groups and self-monitored FBG is a suitable parameter for titration of repaglinide. Whether a lower PPBG target might be as good a guide as FBG for titration of repaglinide should be addressed in a future study.

  15. Prescribing and up-titration in recently hospitalized heart failure patients attending a disease management program.

    PubMed

    Carroll, Robert; Mudge, Alison; Suna, Jessica; Denaro, Charles; Atherton, John

    2016-08-01

    Heart failure (HF) medications improve clinical outcomes, with optimal doses defined in clinical trials. Patient, provider and system barriers may limit achievement of optimal doses in real life settings, although disease management programs (HF-DMPs) can facilitate up-titration. Secondary analysis of a prospective cohort of 216 participants recently hospitalized with systolic HF, attending 5 HF-DMPs in Queensland, Australia. Medication history at baseline (6weeks after discharge) and 6months provided data to describe prescription rates, dosage and optimal titration of HF medications, and associations with patient and system factors were explored. At baseline, 94% were on an angiotensin converting enzyme inhibitor/angiotensin II receptor blocker (ACEI/ARB), 94% on a beta-blocker (BB) and 42% on a mineralocorticoid receptor antagonist (MRA). The proportion of participants on optimal doses of ACEI/ARB increased from 38% (baseline) to 52% (6months, p=0.001) and on optimal BB dose from 23% to 49% (p<0.001). Significant barriers to ACEI/ARB up-titration were body mass index (BMI)<25, female gender, polypharmacy, previously diagnosed HF, and tertiary hospital. Significant barriers for BB up-titration were BMI<25, previously diagnosed HF and non-cardiologist care. Effective up-titration in HF DMPs is influenced by patient, disease and service factors. Better understanding of barriers to effective up-titration in women, normal weight, and established HF patients may help provide targeted strategies for improving outcomes in these groups. Copyright © 2016 Elsevier Ltd. All rights reserved.

  16. When instructions fail. The effects of stimulus control training on brain injury survivors' attending and reporting during hearing screenings.

    PubMed

    Schlund, M W

    2000-10-01

    Bedside hearing screenings are routinely conducted by speech and language pathologists for brain injury survivors during rehabilitation. Cognitive deficits resulting from brain injury, however, may interfere with obtaining estimates of auditory thresholds. Poor comprehension or attention deficits often compromise patient abilities to follow procedural instructions. This article describes the effects of jointly applying behavioral methods and psychophysical methods to improve two severely brain-injured survivors' attending and reporting on auditory test stimuli presentation. Treatment consisted of stimulus control training that involved differentially reinforcing responding in the presence and absence of an auditory test tone. Subsequent hearing screenings were conducted with novel auditory test tones and a common titration procedure. Results showed that prior stimulus control training improved attending and reporting such that hearing screenings were conducted and estimates of auditory thresholds were obtained.

  17. Concurrent determination of total serum calcium and magnesium by thermometric titration with ethylenediaminetetraacetate.

    PubMed

    Callicott, R H; Carr, P W

    1976-07-01

    Total serum calcium and magnesium may be determined in one thermometric titration, with disodium ethylenediaminetetraacetate as the titrant. A 1-ml serum sample is diluted with 1 ml of tris(hydroxymethyl)aminomethane buffer (pH 8) and titrated at a constant rate with a motorized syringe buret. Results by the thermometric method compared well with those by atomic absorption spectroscopy.

  18. Randomized clinical trial of an intravenous hydromorphone titration protocol versus usual care for management of acute pain in older emergency department patients.

    PubMed

    Chang, Andrew K; Bijur, Polly E; Davitt, Michelle; Gallagher, E John

    2013-09-01

    Opioid titration is an effective strategy for treating pain; however, titration is generally impractical in the busy emergency department (ED) setting. Our objective was to test a rapid, two-step, hydromorphone titration protocol against usual care in older patients presenting to the ED with acute severe pain. This was a prospective, randomized clinical trial of patients 65 years of age and older presenting to an adult, urban, academic ED with acute severe pain. The study was registered at http://www.clinicaltrials.gov (NCT01429285). Patients randomized to the hydromorphone titration protocol initially received 0.5 mg intravenous hydromorphone. Patients randomized to usual care received any dose of any intravenous opioid. At 15 min, patients in both groups were asked, 'Do you want more pain medication?' Patients in the hydromorphone titration group who answered 'yes' received a second dose of 0.5 mg intravenous hydromorphone. Patients in the usual care group who answered 'yes' had their ED attending physician notified, who then could administer any (or no) additional medication. The primary efficacy outcome was satisfactory analgesia defined a priori as the patient declining additional analgesia at least once when asked at 15 or 60 min after administration of the initial opioid. Dose was calculated in morphine equivalent units (MEU: 1 mg hydromorphone = 7 mg morphine). The need for naloxone to reverse adverse opioid effects was the primary safety outcome. 83.0 % of 153 patients in the hydromorphone titration group achieved satisfactory analgesia compared with 82.5 % of 166 patients in the usual care group (p = 0.91). Patients in the hydromorphone titration group received lower mean initial doses of opioids at baseline than patients in the usual care group (3.5 MEU vs. 4.7 MEU, respectively; p ≤ 0.001) and lower total opioids through 60 min (5.3 MEU vs. 6.0 MEU; p = 0.03). No patient needed naloxone. Low-dose titration of intravenous hydromorphone in increments of 0.5 mg provides comparable analgesia to usual care with less opioid over 60 min.

  19. A randomised controlled trial evaluating IGF1 titration in contrast to current GH dosing strategies in children born small for gestational age: the North European Small-for-Gestational-Age Study.

    PubMed

    Jensen, Rikke Beck; Thankamony, Ajay; O'Connell, Susan M; Kirk, Jeremy; Donaldson, Malcolm; Ivarsson, Sten-A; Söder, Olle; Roche, Edna; Hoey, Hilary; Dunger, David B; Juul, Anders

    2014-10-01

    Short children born small for gestational age (SGA) are treated with a GH dose based on body size, but treatment may lead to high levels of IGF1. The objective was to evaluate IGF1 titration of GH dose in contrast to current dosing strategies. In the North European Small-for-Gestational-Age Study (NESGAS), 92 short pre-pubertal children born SGA were randomised after 1 year of high-dose GH treatment (67 μg/kg per day) to three different regimens: high dose (67 μg/kg per day), low dose (35 μg/kg per day) or IGF1 titration. The average dose during the second year of the randomised trial did not differ between the IGF1 titration group (38 μg/kg per day, s.d. 0.019) and the low-dose group (35 μg/kg per day, s.d. 0.002; P=0.46), but there was a wide variation in the IGF1 titration group (range 10-80 μg/kg per day). The IGF1 titration group had significantly lower height gain (0.17 SDS, s.d. 0.18) during the second year of the randomised trial compared with the high-dose group (0.46 SDS, s.d. 0.25), but not significantly lower than the low-dose group (0.23 SDS, s.d. 0.15; P=0.17). The IGF1 titration group had lower IGF1 levels after 2 years of the trial (mean 1.16, s.d. 1.24) compared with both the low-dose (mean 1.76, s.d. 1.48) and the high-dose (mean 2.97, s.d. 1.63) groups. IGF1 titration of GH dose in SGA children proved less effective than current dosing strategies. IGF1 titration resulted in physiological IGF1 levels with a wide range of GH dose and a poorer growth response, which indicates the role of IGF1 resistance and highlights the heterogeneity of short SGA children. © 2014 European Society of Endocrinology.

  20. Subject-driven titration of biphasic insulin aspart 30 twice daily is non-inferior to investigator-driven titration in Chinese patients with type 2 diabetes inadequately controlled with premixed human insulin: A randomized, open-label, parallel-group, multicenter trial.

    PubMed

    Yang, Wenying; Zhu, Lvyun; Meng, Bangzhu; Liu, Yu; Wang, Wenhui; Ye, Shandong; Sun, Li; Miao, Heng; Guo, Lian; Wang, Zhanjian; Lv, Xiaofeng; Li, Quanmin; Ji, Qiuhe; Zhao, Weigang; Yang, Gangyi

    2016-01-01

    The present study was to compare the efficacy and safety of subject-driven and investigator-driven titration of biphasic insulin aspart 30 (BIAsp 30) twice daily (BID). In this 20-week, randomized, open-label, two-group parallel, multicenter trial, Chinese patients with type 2 diabetes inadequately controlled by premixed/self-mixed human insulin were randomized 1:1 to subject-driven or investigator-driven titration of BIAsp 30 BID, in combination with metformin and/or α-glucosidase inhibitors. Dose adjustment was decided by patients in the subject-driven group after training, and by investigators in the investigator-driven group. Eligible adults (n = 344) were randomized in the study. The estimated glycated hemoglobin (HbA1c) reduction was 14.5 mmol/mol (1.33%) in the subject-driven group and 14.3 mmol/mol (1.31%) in the investigator-driven group. Non-inferiority of subject-titration vs investigator-titration in reducing HbA1c was confirmed, with estimated treatment difference -0.26 mmol/mol (95% confidence interval -2.05, 1.53) (-0.02%, 95% confidence interval -0.19, 0.14). Fasting plasma glucose, postprandial glucose increment and self-measured plasma glucose were improved in both groups without statistically significant differences. One severe hypoglycemic event was experienced by one subject in each group. A similar rate of nocturnal hypoglycemia (events/patient-year) was reported in the subject-driven (1.10) and investigator-driven (1.32) groups. There were 64.5 and 58.1% patients achieving HbA1c <53.0 mmol/mol (7.0%), and 51.2 and 45.9% patients achieving the HbA1c target without confirmed hypoglycemia throughout the trial in the subject-driven and investigator-driven groups, respectively. Subject-titration of BIAsp 30 BID was as efficacious and well-tolerated as investigator-titration. The present study supported patients to self-titrate BIAsp 30 BID under physicians' supervision.

  1. Sleep Quality, Short-Term and Long-Term CPAP Adherence

    PubMed Central

    Somiah, Manya; Taxin, Zachary; Keating, Joseph; Mooney, Anne M.; Norman, Robert G.; Rapoport, David M.; Ayappa, Indu

    2012-01-01

    Study Objectives: Adherence to CPAP therapy is low in patients with obstructive sleep apnea/hypopnea syndrome (OSAHS). The purpose of the present study was to evaluate the utility of measures of sleep architecture and sleep continuity on the CPAP titration study as predictors of both short- and long-term CPAP adherence. Methods: 93 patients with OSAHS (RDI 42.8 ± 34.3/h) underwent in-laboratory diagnostic polysomnography, CPAP titration, and follow-up polysomnography (NPSG) on CPAP. Adherence to CPAP was objectively monitored. Short-term (ST) CPAP adherence was averaged over 14 days immediately following the titration study. Long-term (LT) CPAP adherence was obtained in 56/93 patients after approximately 2 months of CPAP use. Patients were grouped into CPAP adherence groups for ST (< 2 h, 2-4 h, and > 4 h) and LT adherence (< 4 h, > 4 h). Sleep architecture, sleep disordered breathing (SDB) indices, and daytime outcome variables from the diagnostic and titration NPSGs were compared between CPAP adherence groups. Results: There was a significant relationship between ST and LT CPAP adherence (r = 0.81, p < 0.001). Neither ST nor LT adherence were related to demographic variables, baseline severity of untreated SDB, sleep architecture, or measures of daytime impairment. Good CPAP adherence groups had significantly lower %N2 and greater %REM on the titration NPSG. A model combining change in sleep efficiency and change in sleep continuity between the diagnostic and titration NPSGs predicted 17% of the variance in LT adherence (p = 0.006). Conclusions: These findings demonstrate that characteristics of sleep architecture, even on the titration NPSG, may predict some of the variance in CPAP adherence. Better sleep quality on the titration night was related to better CPAP adherence, suggesting that interventions to improve sleep on/prior to the CPAP titration study might be used as a therapeutic intervention to improve CPAP adherence. Citation: Somiah M; Taxin Z; Keating J; Mooney AM; Norman RG; Rapoport DM; Ayappa I. Sleep quality, short-term and long-term CPAP adherence. J Clin Sleep Med 2012;8(5):489-500. PMID:23066359

  2. Standardizing care and monitoring for anesthesia or procedural sedation delivered outside the operating room.

    PubMed

    Eichhorn, Volker; Henzler, Dietrich; Murphy, Michael F

    2010-08-01

    The purpose of this review is to summarize recommendations for the safe and efficient conductance of sedation and anesthesia at remote locations; and to define safety standards, monitoring techniques, quality of care and procedural eligibility. Anesthesia outside of the operating room is rapidly increasing in numbers, which has seen a growth of older and sicker patients. These circumstances have created a need for guidelines, for both specialist anesthesia providers and nonanesthesia-trained practitioners, that define patient selection, minimum monitoring (hemodynamics and respiration), facility design and equipment, policy framework, recovery facilities and policies. The patient's safety throughout all stages of sedation and/or anesthesia is the most pertinent goal. Recent data emphasize the importance of monitoring pulse oximetry and end-tidal carbon dioxide for any sedating or anesthetic procedure. Substandard monitoring combined with oversedation and subsequent respiratory depression are implicated as the main reasons for catastrophic sedation and anesthetic outcomes at remote locations. Patient selection, procedure appropriateness and location appropriateness are the key elements defining the provision of safe anesthesia care outside the operating room. Titratable, short-acting intravenous drugs are preferred such as propofol and remifentanil.

  3. Photometric Variations of Solar-type Stars: Results of the Cloudcroft Survey

    NASA Technical Reports Server (NTRS)

    Giampapa, M. S.

    1984-01-01

    The results of a synoptic program to search for the occurrence of photometric variability in solar type stars as seen in continuum band photometry are summarized. The survey disclosed the existence of photometric variability in solar type stars that is related to the presence of spots on the stellar surface. The observed variability detected in solar type stars is at enhanced levels compared to that observed for the Sun.

  4. METAPHOR: Probability density estimation for machine learning based photometric redshifts

    NASA Astrophysics Data System (ADS)

    Amaro, V.; Cavuoti, S.; Brescia, M.; Vellucci, C.; Tortora, C.; Longo, G.

    2017-06-01

    We present METAPHOR (Machine-learning Estimation Tool for Accurate PHOtometric Redshifts), a method able to provide a reliable PDF for photometric galaxy redshifts estimated through empirical techniques. METAPHOR is a modular workflow, mainly based on the MLPQNA neural network as internal engine to derive photometric galaxy redshifts, but giving the possibility to easily replace MLPQNA with any other method to predict photo-z's and their PDF. We present here the results about a validation test of the workflow on the galaxies from SDSS-DR9, showing also the universality of the method by replacing MLPQNA with KNN and Random Forest models. The validation test include also a comparison with the PDF's derived from a traditional SED template fitting method (Le Phare).

  5. Photometric imaging in particle size measurement and surface visualization.

    PubMed

    Sandler, Niklas

    2011-09-30

    The aim of this paper is to give an insight into photometric particle sizing approaches, which differ from the typical particle size measurement of dispersed particles. These approaches can often be advantageous especially for samples that are moist or cohesive, when dispersion of particles is difficult or sometimes impossible. The main focus of this paper is in the use of photometric stereo imaging. The technique allows the reconstruction of three-dimensional images of objects using multiple light sources in illumination. The use of photometric techniques is demonstrated in at-line measurement of granules and on-line measurement during granulation and dry milling. Also, surface visualization and roughness measurements are briefly discussed. Copyright © 2010 Elsevier B.V. All rights reserved.

  6. Photometry with FORS

    NASA Astrophysics Data System (ADS)

    Freudling, W.; Møller, P.; Patat, F.; Moehler, S.; Romaniello, M.; Jehin, E.; O'Brien, K.; Izzo, C.; Pompei, E.

    Photometric calibration observations are routinely carried out with all ESO imaging cameras in every clear night. The nightly zeropoints derived from these observations are accurate to about 10%. Recently, we have started the FORS Absolute Photometry Project (FAP) to investigate, if and how percent-level absolute photometric accuracy can be achieved with FORS1, and how such photometric calibration can be offered to observers. We found that there are significant differences between the sky-flats and the true photometric response of the instrument which partially depend on the rotator angle. A second order correction to the sky-flat significantly improves the relative photometry within the field. We demonstrate the feasibility of percent level photometry and describe the calibrations necessary to achieve that level of accuracy.

  7. Photometric calibration of NGS/POSS and ESO/SRC plates using the NOAO PDS measuring engine. I - Stellar photometry

    NASA Technical Reports Server (NTRS)

    Cutri, Roc M.; Low, Frank J.; Marvel, Kevin B.

    1992-01-01

    The PDS/Monet measuring engine at the National Optical Astronomy Observatory was used to obtain photometry of nearly 10,000 stars on the NGS/POSS and 2000 stars on the ESO/SRC Survey glass plates. These measurements have been used to show that global transformation functions exist that allow calibration of stellar photometry from any blue or red plate to equivalent Johnson B and Cousins R photoelectric magnitudes. The four transformation functions appropriate for the POSS O and E and ESO/SRC J and R plates were characterized, and it was found that, within the measurement uncertainties, they vary from plate to plate only by photometric zero-point offsets. A method is described to correct for the zero-point shifts and to obtain calibrated B and R photometry of stellar sources to an average accuracy of 0.3-0.4 mag within the range R between values of 8 and 19.5 for red plates in both surveys, B between values of 9 and 20.5 on POSS blue plates, and B between values of 10 and 20.5 on ESO/SRC blue plates. This calibration procedure makes it possible to obtain rapid photometry of very large numbers of stellar sources.

  8. Broadband Radiometric LED Measurements

    PubMed Central

    Eppeldauer, G. P.; Cooksey, C. C.; Yoon, H. W.; Hanssen, L. M.; Podobedov, V. B.; Vest, R. E.; Arp, U.; Miller, C. C.

    2017-01-01

    At present, broadband radiometric measurements of LEDs with uniform and low-uncertainty results are not available. Currently, either complicated and expensive spectral radiometric measurements or broadband photometric LED measurements are used. The broadband photometric measurements are based on the CIE standardized V(λ) function, which cannot be used in the UV range and leads to large errors when blue or red LEDs are measured in its wings, where the realization is always poor. Reference irradiance meters with spectrally constant response and high-intensity LED irradiance sources were developed here to implement the previously suggested broadband radiometric LED measurement procedure [1, 2]. Using a detector with spectrally constant response, the broadband radiometric quantities of any LEDs or LED groups can be simply measured with low uncertainty without using any source standard. The spectral flatness of filtered-Si detectors and low-noise pyroelectric radiometers are compared. Examples are given for integrated irradiance measurement of UV and blue LED sources using the here introduced reference (standard) pyroelectric irradiance meters. For validation, the broadband measured integrated irradiance of several LED-365 sources were compared with the spectrally determined integrated irradiance derived from an FEL spectral irradiance lamp-standard. Integrated responsivity transfer from the reference irradiance meter to transfer standard and field UV irradiance meters is discussed. PMID:28649167

  9. Broadband Radiometric LED Measurements.

    PubMed

    Eppeldauer, G P; Cooksey, C C; Yoon, H W; Hanssen, L M; Podobedov, V B; Vest, R E; Arp, U; Miller, C C

    2016-01-01

    At present, broadband radiometric measurements of LEDs with uniform and low-uncertainty results are not available. Currently, either complicated and expensive spectral radiometric measurements or broadband photometric LED measurements are used. The broadband photometric measurements are based on the CIE standardized V(λ) function, which cannot be used in the UV range and leads to large errors when blue or red LEDs are measured in its wings, where the realization is always poor. Reference irradiance meters with spectrally constant response and high-intensity LED irradiance sources were developed here to implement the previously suggested broadband radiometric LED measurement procedure [1, 2]. Using a detector with spectrally constant response, the broadband radiometric quantities of any LEDs or LED groups can be simply measured with low uncertainty without using any source standard. The spectral flatness of filtered-Si detectors and low-noise pyroelectric radiometers are compared. Examples are given for integrated irradiance measurement of UV and blue LED sources using the here introduced reference (standard) pyroelectric irradiance meters. For validation, the broadband measured integrated irradiance of several LED-365 sources were compared with the spectrally determined integrated irradiance derived from an FEL spectral irradiance lamp-standard. Integrated responsivity transfer from the reference irradiance meter to transfer standard and field UV irradiance meters is discussed.

  10. Extinction, seeing and sky transparency monitoring at the Observatorio Astrofísico de Javalambre for J-PAS and J-PLUS calibration and scheduling

    NASA Astrophysics Data System (ADS)

    Vázquez Ramió, H.; Díaz-Martín, M. C.; Varela, J.; Ederoclite, A.; Maícas, N. Lamadrid, J. L.; Abril, J.; Iglesias-Marzoa, R.; Rodríguez, S.; Tilve, V.; Cenarro, A. J.; Antón Bravo, J. L.; Bello Ferrer, R.; Cristóbal-Hornillos, D.; Guillén Civera, L.; Hernández-Fuertes, J.; Jiménez Mejías, D.; Lasso-Cabrera, N. M.; López Alegre, G.; López Sainz, A.; Luis-Simoes, R. M.; Marín-Franch, A.; Moles, M.; Rueda-Teruel, F.; Rueda-Teruel, S.; Suárez López, O.; Yanes-Díaz, A.

    2015-05-01

    The Javalambre-Physics of the Accelerating Universe Astrophysical Survey (J-PAS; see Benítez et al. 2014) and the Javalambre-Photometric Local Universe Survey (J-PLUS) will be conducted at the brand-new Observatorio Astrofísico de Javalambre (OAJ) in Teruel, Spain. J-PLUS is planned to start by the first half of 2015 while J-PAS first light is expected to happen along 2015. Besides the two main telescopes (with 2.5 m and 80 cm apertures), several smaller-sized facilities are present at the OAJ devoted to site characterization and supporting measurements to be used to calibrate the J-PAS and J-PLUS photometry and to feed up the OAJ's Sequencer with the integrated seeing and the sky transparency. These instruments are: i) an extinction monitor, an 11 " telescope estimating the atmospheric extinction to finally obtain the OAJ extinction curve, which is the initial step to J-PAS overall photometric calibration procedure; ii) an 8 " telescope implementing the Differential Image Motion Monitor (DIMM) technique to obtain the integrated seeing; and iii) an All-Sky Transmission MONitor (ASTMON), a roughly all-sky instrument providing the sky transparency as well as sky brightness and the atmospheric extinction too.

  11. Standardized Photometric Calibrations for Panchromatic SSA Sensors

    NASA Astrophysics Data System (ADS)

    Castro, P.; Payne, T.; Battle, A.; Cole, Z.; Moody, J.; Gregory, S.; Dao, P.

    2016-09-01

    Panchromatic sensors used for Space Situational Awareness (SSA) have no standardized method for transforming the net flux detected by a CCD without a spectral filter into an exo-atmospheric magnitude in a standard magnitude system. Each SSA data provider appears to have their own method for computing the visual magnitude based on panchromatic brightness making cross-comparisons impossible. We provide a procedure in order to standardize the calibration of panchromatic sensors for the purposes of SSA. A technique based on theoretical modeling is presented that derives standard panchromatic magnitudes from the Johnson-Cousins photometric system defined by Arlo Landolt. We verify this technique using observations of Landolt standard stars and a Vega-like star to determine empirical panchromatic magnitudes and compare these to synthetically derived panchromatic magnitudes. We also investigate color terms caused by differences in the quantum efficiency (QE) between the Landolt standard system and panchromatic systems. We evaluate calibrated panchromatic satellite photometry by observing several GEO satellites and standard stars using three different sensors. We explore the effect of satellite color terms by comparing the satellite signatures. In order to remove other variables affecting the satellite photometry, two of the sensors are at the same site using different CCDs. The third sensor is geographically separate from the first two allowing for a definitive test of calibrated panchromatic satellite photometry.

  12. THE MID-INFRARED TULLY-FISHER RELATION: SPITZER SURFACE PHOTOMETRY

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sorce, Jenny G.; Courtois, Helene M.; Tully, R. Brent, E-mail: j.sorce@ipnl.in2p3.fr

    2012-11-01

    The availability of photometric imaging of several thousand galaxies with the Spitzer Space Telescope enables a mid-infrared calibration of the correlation between luminosity and rotation in spiral galaxies. The most important advantage of the new calibration in the 3.6 {mu}m band, IRAC Channel 1, is photometric consistency across the entire sky. Additional advantages are minimal obscuration, observations of flux dominated by old stars, and sensitivity to low surface brightness levels due to favorable backgrounds. Roughly 3000 galaxies have been observed through Spitzer cycle 7 and images of these are available from the Spitzer archive. In cycle 8, a program calledmore » Cosmic Flows with Spitzer was initiated, which will increase the available sample of spiral galaxies with inclinations greater than 45 Degree-Sign from face-on that are suitable for distance measurements by 1274. This paper describes procedures, based on the photometry package Archangel, that are being employed to analyze both the archival and new data in a uniform way. We give results for 235 galaxies, our calibrator sample for the Tully-Fisher relation. Galaxy magnitudes are determined with uncertainties held below 0.05 mag for normal spiral systems. A subsequent paper will describe the calibration of the [3.6] luminosity-rotation relation.« less

  13. Estimating metallicities with isochrone fits to photometric data of open clusters

    NASA Astrophysics Data System (ADS)

    Monteiro, H.; Oliveira, A. F.; Dias, W. S.; Caetano, T. C.

    2014-10-01

    The metallicity is a critical parameter that affects the correct determination of stellar cluster's fundamental characteristics and has important implications in Galactic and Stellar evolution research. Fewer than 10% of the 2174 currently catalogued open clusters have their metallicity determined in the literature. In this work we present a method for estimating the metallicity of open clusters via non-subjective isochrone fitting using the cross-entropy global optimization algorithm applied to UBV photometric data. The free parameters distance, reddening, age, and metallicity are simultaneously determined by the fitting method. The fitting procedure uses weights for the observational data based on the estimation of membership likelihood for each star, which considers the observational magnitude limit, the density profile of stars as a function of radius from the center of the cluster, and the density of stars in multi-dimensional magnitude space. We present results of [Fe/H] for well-studied open clusters based on distinct UBV data sets. The [Fe/H] values obtained in the ten cases for which spectroscopic determinations were available in the literature agree, indicating that our method provides a good alternative to estimating [Fe/H] by using an objective isochrone fitting. Our results show that the typical precision is about 0.1 dex.

  14. Analysis of titanium content in titanium tetrachloride solution

    NASA Astrophysics Data System (ADS)

    Bi, Xiaoguo; Dong, Yingnan; Li, Shanshan; Guan, Duojiao; Wang, Jianyu; Tang, Meiling

    2018-03-01

    Strontium titanate, barium titan and lead titanate are new type of functional ceramic materials with good prospect, and titanium tetrachloride is a commonly in the production such products. Which excellent electrochemical performance of ferroelectric tempreature coefficient effect.In this article, three methods are used to calibrate the samples of titanium tetrachloride solution by back titration method, replacement titration method and gravimetric analysis method. The results show that the back titration method has many good points, for example, relatively simple operation, easy to judgment the titration end point, better accuracy and precision of analytical results, the relative standard deviation not less than 0.2%. So, it is the ideal of conventional analysis methods in the mass production.

  15. Correct titration of non-drugs and some other methodological issues.

    PubMed

    Beneke, M; Rasmus, W; Rød, I S; Fritze, J

    1994-01-01

    Doctors' prescription and dosing behaviour was investigated using data from 9 clinical trials in 550 patients treated with psychotropics. 7 trials were conducted under double- and 2 under single-blind conditions. In 3 of these trials, oral and i.m. preparations were used demanding a double-dummy design. All patients were evaluated on a weekly or 2-week basis using psychopathological rating scales (i.e. Hamilton Anxiety Scale, Hamilton Depression Scale, Clinical Global Impressions, Simpson and Angus EPS). It was found that (a) oral-medication titration was 3- to 4-fold more broad-ranging than i.m. medication titration, (b) oral placebo was titrated to the same extent as the oral investigational drugs, and (c) the titration schedule did not follow protocol requirements. Moreover, the average doses in all drug and placebo groups were the same. Concomitant medication like sleep inducers was found to be more closely related to doctors' habits than to actual medical need. Independent of trial and investigational drug, 10-33% of all patients received additional sleep inducers.

  16. Multiple Diphtheria Antigen-Antibody Systems Investigated by Passive Haemagglutination Techniques and Other Methods

    PubMed Central

    Fulthorpe, A. J.

    1962-01-01

    A fair degree of correlation has been found between the in vivo antitoxin content of sera from horses immunized with crude Corynebacterium diphtheriae culture filtrates and the direct agglutinin titre of the sera when tested with sheep cells sensitized with diphtheria toxoid. Haemagglutination inhibition tests at the LA level of test with the same sera showed some rather large discrepancies from the in vivo and further tests with special agglutinin inhibiting toxins suggested that specific antitoxin free from other accessory antibodies might be non-agglutinating, and therefore not titratable by haemagglutination inhibition. The phosphate-stable, pepsin-stable and trypsin-stable antigens isolated from culture filtrates of C. diphtheriae were found to contain extremely small quantities of specific toxoid, and cross titration of each of the three antigen preparations showed that there was very little contamination by other antigens within the group. Absorption of diphtheria antiserum with red cells sensitized with each of the three accessory antigens individually, showed that the antibodies were highly specific and distinct. Absorption of diphtheria antiserum with a mixture of red cells sensitized with the three different antigens removed all demonstrable accessory antibodies, and the absorbed serum would no longer agglutinate cells sensitized with complete diphtheria toxoid. The absorbed serum, however, retained a large proportion of its neutralizing capacity for diphtheria toxin, when titrated in vivo. Titration of each of the accessory antibodies in a number of horse sera by haemagglutination inhibition demonstrated a correlation between the values for the accessory antibodies to the phosphate-stable and pepsin-stable antigens, but no correlation with the values for the antibody to the trypsin-stable antigen, when compared with results of the flocculation test. The relative proportions of diphtheria toxin and of the phosphate-stable and pepsin-stable antigens remained constant at all stages of purification of a filtrate including several recrystallization procedures. However, the concentration of the trypsin-stable antigen declined steadily during the process. The relative proportions of toxin, phosphate-stable and pepsin-stable antigens in several crude culture filtrates were constant under reasonable conditions of storage and very varied where deterioration had occurred. These three antigens also maintained a constant ratio in growing culture, the trypsin-stable antigen did not. PMID:13895880

  17. Photometric diversity of terrains on Triton

    NASA Technical Reports Server (NTRS)

    Hillier, J.; Veverka, J.; Helfenstein, P.; Lee, P.

    1994-01-01

    Voyager disk-resolved images of Triton in the violet (0.41 micrometers) and green (0.56 micrometer wavelengths have been analyzed to derive the photometric characteristics of terrains on Triton. Similar conclusions are found using two distinct but related definitions of photometric units, one based on color ratio and albedo properties (A. S. McEwen, 1990), the other on albedo and brightness ratios at different phase angles (P. Lee et al., 1992). A significant diversity of photometric behavior, much broader than that discovered so far on any other icy satellite, occurs among Triton's terrains. Remarkably, differences in photometric behavior do not correlate well with geologic terrain boundaries defined on the basis of surface morphology. This suggests that in most cases photometric properties on Triton are controlled by thin deposits superposed on underlying geologic units. Single scattering albedos are 0.98 or higher and asymmetry factors range from -0.35 to -0.45 for most units. The most distinct scattering behavior is exhibited by the reddish northern units already identified as the Anomalously Scattering Region (ASR), which scatters light almost isotropically with g = -0.04. In part due to the effects of Triton's clouds and haze, it is difficult to constrain the value of bar-theta, Hapke's macroscopic roughness parameter, precisely for Triton or to map differences in bar-theta among the different photometric terrains. However, our study shows that Triton must be relatively smooth, with bar-theta less than 15-20 degs and suggests that a value of 14 degs is appropriate. The differences in photometric characteristics lead to significantly different phase angle behavior for the various terrains. For example, a terrain (e.g., the ASR) that appears dark relative to another at low phase angles will reverse its contrast (become relatively brighter) at larger phase angles. The photometric parameters have been used to calculate hemispherical albedos for the units and to infer likely surface temperatures. Based on these results, we determine that all but the most southerly regions (i.e., mostly south of the equator) of the reddish northern terrains are likely to have been covered with deposits of nitrogen frost at the time of the Voyager flyby, in agreement with the suggestion from the photometry that these units are overlain by a thin veneer of material.

  18. An Ion-Selective Electrode for the Determination of Phencyclidine (PCP).

    DTIC Science & Technology

    1980-08-06

    as an indicator_ ectrode in potentiometric titration of PCPA at concentrations DD 1473 EDITION or I Nov soIS OSSOOL TC SEPURqITY CLAWSFICATION Of...and ISE detection limits determined as described previous (25). The PCP electrode was used as the indicator electrode in potentiometric titrations of...was standardized by potentiometric titration with a dodecyltrimethyl- ammonium bromide (DoTAB) solution using a DoTA+ ISE (25) as the indicator

  19. [Not Available].

    PubMed

    Burgot, J L

    1978-04-01

    Maleic, fumaric, tartaric, glutaric and adipic acids are titrated directly with sodium hydroxide by means of an automatic thermometric titrimeter. The titration curves have two break-points, corresponding to the successive neutralization of the two acid groups. Previous standardization permits measurement of the heats of neutralization, from which the enthalpies of dissociation can be deduced. From 0.3 to 1 mmole of acid can be titrated with a relative standard deviation of about 3%.

  20. Use of vitreous carbon as a working electrode in coulometric titration of potassium hydrogen phthalate.

    PubMed

    Jennings, V J; Dodson, A; Tedds, G

    1973-07-01

    The use of a vitreous carbon electrode as a cathode in the amperostatic coulometric titration of aqueous potassium hydrogen phthalate solution is described. It is shown that 10 mg of the phthalate can be titrated with a precision better than 0.5%. Current-voltage curves for platinum and vitreous carbon cathodes show that there is an overpotential on the latter relative to the former.

  1. Reduction and determination of dixanthogens.

    PubMed

    Prasad, M S

    1971-06-01

    A convenient method for the reduction and determination of dixaathogen has been developed. It is based on the quantitative reaction of dixanthogen with zinc amalgam to form xanthate; the latter can be determined by iodine titration, potentiometric titration with silver nitrate or by spectrophotometry at 310 mmu. Dixanthogen can be determined in mixtures containing xanthate, by titration of aliquots with and without reduction. Higher dixanthogens can also be determined, and flotation liquors analysed.

  2. A stable and convenient protein electrophoresis titration device with bubble removing system.

    PubMed

    Zhang, Qiang; Fan, Liu-Yin; Li, Wen-Lin; Cong, Feng-Song; Zhong, Ran; Chen, Jing-Jing; He, Yu-Chen; Xiao, Hua; Cao, Cheng-Xi

    2017-07-01

    Moving reaction boundary titration (MRBT) has a potential application to immunoassay and protein content analysis with high selectivity. However, air bubbles often impair the accuracy of MRBT, and the leakage of electrolyte greatly decreases the safety and convenience of electrophoretic titration. Addressing these two issues a reliable MRBT device with modified electrolyte chamber of protein titration was designed. Multiphysics computer simulation was conducted for optimization according to two-phase flow. The single chamber was made of two perpendicular cylinders with different diameters. After placing electrophoretic tube, the resident air in the junction next to the gel could be eliminated by a simple fast electrolyte flow. Removing the electrophoretic tube automatically prevented electrolyte leakage at the junction due to the gravity-induced negative pressure within the chamber. Moreover, the numerical simulation and experiments showed that the improved MRBT device has following advantages: (i) easy and rapid setup of electrophoretic tube within 20 s; (ii) simple and quick bubble dissipates from the chamber of titration within 2 s; (iii) no electrolyte leakage from the two chambers: and (iv) accurate protein titration and safe instrumental operation. The developed technique and apparatus greatly improves the performance of the previous MRBT device, and providing a new route toward practical application. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. Comparison of a gel microcolumn assay with the conventional tube test for red blood cell alloantibody titration.

    PubMed

    Finck, Rachel; Lui-Deguzman, Carrie; Teng, Shih-Mao; Davis, Rebecca; Yuan, Shan

    2013-04-01

    Titration is a semiquantitative method used to estimate red blood cell (RBC) alloantibody reactivity. The conventional tube test (CTT) technique is the traditional method for performing titration studies. The gel microcolumn assay (GMA) is also a sensitive method to detect RBC alloantibodies. The aim of this study was to compare a GMA with the CTT technique in the performance of Rh and K alloantibody titration. Patient serum samples that contained an RBC alloantibody with a singular specificity were identified by routine blood bank workflow. Parallel titration studies were performed on these samples by both the CTT method and a GMA (ID-Micro Typing System anti-IgG gel card, Micro Typing Systems, Inc., an Ortho-Clinical Diagnostics Company). Forty-eight samples were included, including 11 anti-D, five anti-c, 13 anti-E, one anti-C, three anti-e, and 15 anti-K. Overall, the two methods generated identical results in 21 of 48 samples. For 42 samples (87.5%) the two methods generated results that were within one serial dilution, and for the remaining six samples, results were within two dilutions. GMA systems may perform comparably to the CTT in titrating alloantibodies to Rh and Kell antigens. © 2012 American Association of Blood Banks.

  4. Stellar variability and its implications for photometric planet detection with Kepler

    NASA Astrophysics Data System (ADS)

    Batalha, N. M.; Jenkins, J.; Basri, G. S.; Borucki, W. J.; Koch, D. G.

    2002-01-01

    Kepler is one of three candidates for the next NASA Discovery Mission and will survey the extended solar neighborhood to detect and characterize hundreds of terrestrial (and larger) planets in or near the habitable zone. Its strength lies in its ability to detect large numbers of Earth-sized planets - planets which produced a 10-4 change in relative stellar brightness during a transit across the disk of a sun-like parent star. Such a detection requires high instrumental relative precision and is facilitated by observing stars which are photometrically quiet on hourly timescales. Probing stellar variability across the HR diagram, one finds that many of the photometrically quietest stars are the F and G dwarfs. The Hipparcos photometric database shows the lowest photometric variances among stars of this spectral class. Our own Sun is a prime example with RMS variations over a few rotational cycles of typically (3 - 4)×10-4 (computed from VIRGO/DIARAD data taken Jan-Mar 2001). And variability on the hourly time scales crucial for planet detection is significantly smaller: just (2 - 5)×10-5. This bodes well for planet detection programs such as Kepler and Eddington. With significant numbers of photometrically quiet solar-type stars, Earth-sized planets should be readily identified provided they are abundant in the solar neighborhood. In support of the Kepler science objectives, we have initiated a study of stellar variability and its implications for planet detection. Herein, we summarize existing observational and theoretrical work with the objective of determining the percentage of stars in the Kepler field of view expected to be photometrically stable at a level which allows for Earth-sized planet detection.

  5. CFHTLenS and RCSLenS: testing photometric redshift distributions using angular cross-correlations with spectroscopic galaxy surveys

    NASA Astrophysics Data System (ADS)

    Choi, A.; Heymans, C.; Blake, C.; Hildebrandt, H.; Duncan, C. A. J.; Erben, T.; Nakajima, R.; Van Waerbeke, L.; Viola, M.

    2016-12-01

    We determine the accuracy of galaxy redshift distributions as estimated from photometric redshift probability distributions p(z). Our method utilizes measurements of the angular cross-correlation between photometric galaxies and an overlapping sample of galaxies with spectroscopic redshifts. We describe the redshift leakage from a galaxy photometric redshift bin j into a spectroscopic redshift bin I using the sum of the p(z) for the galaxies residing in bin j. We can then predict the angular cross-correlation between photometric and spectroscopic galaxies due to intrinsic galaxy clustering when I ≠ j as a function of the measured angular cross-correlation when I = j. We also account for enhanced clustering arising from lensing magnification using a halo model. The comparison of this prediction with the measured signal provides a consistency check on the validity of using the summed p(z) to determine galaxy redshift distributions in cosmological analyses, as advocated by the Canada-France-Hawaii Telescope Lensing Survey (CFHTLenS). We present an analysis of the photometric redshifts measured by CFHTLenS, which overlaps the Baryon Oscillation Spectroscopic Survey (BOSS). We also analyse the Red-sequence Cluster Lensing Survey, which overlaps both BOSS and the WiggleZ Dark Energy Survey. We find that the summed p(z) from both surveys are generally biased with respect to the true underlying distributions. If unaccounted for, this bias would lead to errors in cosmological parameter estimation from CFHTLenS by less than ˜4 per cent. For photometric redshift bins which spatially overlap in 3D with our spectroscopic sample, we determine redshift bias corrections which can be used in future cosmological analyses that rely on accurate galaxy redshift distributions.

  6. Effects of illumination differences on photometric stereo shape-and-albedo-from-shading for precision lunar surface reconstruction

    NASA Astrophysics Data System (ADS)

    Chung Liu, Wai; Wu, Bo; Wöhler, Christian

    2018-02-01

    Photoclinometric surface reconstruction techniques such as Shape-from-Shading (SfS) and Shape-and-Albedo-from-Shading (SAfS) retrieve topographic information of a surface on the basis of the reflectance information embedded in the image intensity of each pixel. SfS or SAfS techniques have been utilized to generate pixel-resolution digital elevation models (DEMs) of the Moon and other planetary bodies. Photometric stereo SAfS analyzes images under multiple illumination conditions to improve the robustness of reconstruction. In this case, the directional difference in illumination between the images is likely to affect the quality of the reconstruction result. In this study, we quantitatively investigate the effects of illumination differences on photometric stereo SAfS. Firstly, an algorithm for photometric stereo SAfS is developed, and then, an error model is derived to analyze the relationships between the azimuthal and zenith angles of illumination of the images and the reconstruction qualities. The developed algorithm and error model were verified with high-resolution images collected by the Narrow Angle Camera (NAC) of the Lunar Reconnaissance Orbiter Camera (LROC). Experimental analyses reveal that (1) the resulting error in photometric stereo SAfS depends on both the azimuthal and the zenith angles of illumination as well as the general intensity of the images and (2) the predictions from the proposed error model are consistent with the actual slope errors obtained by photometric stereo SAfS using the LROC NAC images. The proposed error model enriches the theory of photometric stereo SAfS and is of significance for optimized lunar surface reconstruction based on SAfS techniques.

  7. HFF-DeepSpace Photometric Catalogs of the 12 Hubble Frontier Fields, Clusters, and Parallels: Photometry, Photometric Redshifts, and Stellar Masses

    NASA Astrophysics Data System (ADS)

    Shipley, Heath V.; Lange-Vagle, Daniel; Marchesini, Danilo; Brammer, Gabriel B.; Ferrarese, Laura; Stefanon, Mauro; Kado-Fong, Erin; Whitaker, Katherine E.; Oesch, Pascal A.; Feinstein, Adina D.; Labbé, Ivo; Lundgren, Britt; Martis, Nicholas; Muzzin, Adam; Nedkova, Kalina; Skelton, Rosalind; van der Wel, Arjen

    2018-03-01

    We present Hubble multi-wavelength photometric catalogs, including (up to) 17 filters with the Advanced Camera for Surveys and Wide Field Camera 3 from the ultra-violet to near-infrared for the Hubble Frontier Fields and associated parallels. We have constructed homogeneous photometric catalogs for all six clusters and their parallels. To further expand these data catalogs, we have added ultra-deep K S -band imaging at 2.2 μm from the Very Large Telescope HAWK-I and Keck-I MOSFIRE instruments. We also add post-cryogenic Spitzer imaging at 3.6 and 4.5 μm with the Infrared Array Camera (IRAC), as well as archival IRAC 5.8 and 8.0 μm imaging when available. We introduce the public release of the multi-wavelength (0.2–8 μm) photometric catalogs, and we describe the unique steps applied for the construction of these catalogs. Particular emphasis is given to the source detection band, the contamination of light from the bright cluster galaxies (bCGs), and intra-cluster light (ICL). In addition to the photometric catalogs, we provide catalogs of photometric redshifts and stellar population properties. Furthermore, this includes all the images used in the construction of the catalogs, including the combined models of bCGs and ICL, the residual images, segmentation maps, and more. These catalogs are a robust data set of the Hubble Frontier Fields and will be an important aid in designing future surveys, as well as planning follow-up programs with current and future observatories to answer key questions remaining about first light, reionization, the assembly of galaxies, and many more topics, most notably by identifying high-redshift sources to target.

  8. Multiple Populations in NGC 1851: Abundance Variations and UV Photometric Synthesis in the Washington and HST /WFC3 Systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cummings, Jeffrey D.; Geisler, D.; Villanova, S.

    The analysis of multiple populations (MPs) in globular clusters (GCs), both spectroscopically and photometrically, is key in understanding their formation and evolution. The relatively narrow Johnson U, F336W, and Stromgren and Sloan u filters have been crucial in exhibiting these MPs photometrically, but in Paper I we showed that the broader Washington C filter can more efficiently detect MPs in the test case GC NGC 1851. Additionally, In Paper I we detected a double main sequence (MS) that has not been detected in previous observations of NGC 1851. We now match this photometry to NGC 1851's published RGB abundances andmore » find that the two RGB branches observed in C generally exhibit different abundance characteristics in a variety of elements (e.g., Ba, Na, and O) and in CN band strengths, but no single element can define the two RGB branches. However, simultaneously considering [Ba/Fe] or CN strength with either [Na/Fe], [O/Fe], or CN strength can separate the two photometric RGB branches into two distinct abundance groups. Matches of NGC 1851's published SGB and HB abundances to the Washington photometry shows consistent characterizations of the MPs, which can be defined as an O-rich/N-normal population and an O-poor/N-rich population. Photometric synthesis for both the Washington C filter and the F336W filter finds that these abundance characteristics, with appropriate variations in He, can reproduce for both filters the photometric observations in both the RGB and the MS. This photometric synthesis also confirms the throughput advantages that the C filter has in detecting MPs.« less

  9. Multiple Populations in NGC 1851: Abundance Variations and UV Photometric Synthesis in the Washington and HST/WFC3 Systems

    NASA Astrophysics Data System (ADS)

    Cummings, Jeffrey D.; Geisler, D.; Villanova, S.

    2017-04-01

    The analysis of multiple populations (MPs) in globular clusters (GCs), both spectroscopically and photometrically, is key in understanding their formation and evolution. The relatively narrow Johnson U, F336W, and Stromgren and Sloan u filters have been crucial in exhibiting these MPs photometrically, but in Paper I we showed that the broader Washington C filter can more efficiently detect MPs in the test case GC NGC 1851. Additionally, In Paper I we detected a double main sequence (MS) that has not been detected in previous observations of NGC 1851. We now match this photometry to NGC 1851's published RGB abundances and find that the two RGB branches observed in C generally exhibit different abundance characteristics in a variety of elements (e.g., Ba, Na, and O) and in CN band strengths, but no single element can define the two RGB branches. However, simultaneously considering [Ba/Fe] or CN strength with either [Na/Fe], [O/Fe], or CN strength can separate the two photometric RGB branches into two distinct abundance groups. Matches of NGC 1851's published SGB and HB abundances to the Washington photometry shows consistent characterizations of the MPs, which can be defined as an O-rich/N-normal population and an O-poor/N-rich population. Photometric synthesis for both the Washington C filter and the F336W filter finds that these abundance characteristics, with appropriate variations in He, can reproduce for both filters the photometric observations in both the RGB and the MS. This photometric synthesis also confirms the throughput advantages that the C filter has in detecting MPs.

  10. Down-titration of biologics for the treatment of rheumatoid arthritis: a systematic literature review.

    PubMed

    Lau, Chak Sing; Gibofsky, Allan; Damjanov, Nemanja; Lula, Sadiq; Marshall, Lisa; Jones, Heather; Emery, Paul

    2017-11-01

    Biologic therapies have improved the management of rheumatoid arthritis (RA) and the treat-to-target approach has resulted in many patients achieving remission. In the current treatment landscape, clinicians have begun considering dose reduction/tapering for their patients. Rheumatology guidelines in Asia, Europe, and the United States include down-titration of biologics but admit that the level of evidence is moderate. We conducted a systematic literature review to assess the published studies that evaluate down-titration of biologics in RA. The published literature was searched for studies that down-titrated the following biologics: abatacept, adalimumab, certolizumab, etanercept, golimumab, infliximab, rituximab, and tocilizumab. Eligible studies included randomized controlled trials (RCTs), non-RCTs, observational, and pharmacoeconomic studies. The outcomes of interest were (1) efficacy and health-related quality of life, (2) disease flares, and (3) impact on cost. Eleven full-text publications were identified; only three were RCTs. Study results suggest that dosing down may be an option in many patients who have achieved remission or low disease activity. However, some patients are likely to experience a disease flare. Across the studies, the definition of disease flare and the down-titration criteria were inconsistent, making it difficult to conclude which patients may be appropriate and when to attempt down-titration. Studies have evaluated the practice of dosing down biologic therapy in patients with RA; however, a relatively small number of RCTs have been published. Although down-titration may be an option for some patients in LDA or remission, additional RCTs are needed to provide guidance on this practice.

  11. Color Transformations for the 2MASS Second Incremental Data Release

    NASA Astrophysics Data System (ADS)

    Carpenter, John M.

    2001-05-01

    Transformation equations are presented to convert colors and magnitudes measured in the AAO, ARNICA, CIT, DENIS, ESO, LCO (Persson standards), MSSSO, SAAO, and UKIRT photometric systems to the photometric system inherent in the 2MASS Second Incremental Data Release. The transformations have been derived by comparing 2MASS photometry with published magnitudes and colors for stars observed in these systems. Transformation equations have also been derived indirectly for the Bessell & Brett and Koornneef homogenized photometric systems.

  12. Kepler Mission Design, Realized Photometric Performance, and Early Science

    DTIC Science & Technology

    2010-04-20

    USA 19 Institute for Astronomy, University of Hawaii, Honolulu, HI 96822, USA 20 Ball Aerospace and Technologies Corp., Boulder, CO 80306, USA 21...was to perform multi-band photometric observations using a filter set similar to the Sloan Survey (g, r, i, z ) with the addition of a filter for the...Dynamic range 7 Kp 17 Meets photometric precision Operating temperature −85 ◦C 10 mK stability Controller Ball Aerospace Design and manufacturer

  13. Photometric correction for an optical CCD-based system based on the sparsity of an eight-neighborhood gray gradient.

    PubMed

    Zhang, Yuzhong; Zhang, Yan

    2016-07-01

    In an optical measurement and analysis system based on a CCD, due to the existence of optical vignetting and natural vignetting, photometric distortion, in which the intensity falls off away from the image center, affects the subsequent processing and measuring precision severely. To deal with this problem, an easy and straightforward method used for photometric distortion correction is presented in this paper. This method introduces a simple polynomial fitting model of the photometric distortion function and employs a particle swarm optimization algorithm to get these model parameters by means of a minimizing eight-neighborhood gray gradient. Compared with conventional calibration methods, this method can obtain the profile information of photometric distortion from only a single common image captured by the optical CCD-based system, with no need for a uniform luminance area source used as a standard reference source and relevant optical and geometric parameters in advance. To illustrate the applicability of this method, numerical simulations and photometric distortions with different lens parameters are evaluated using this method in this paper. Moreover, the application example of temperature field correction for casting billets also demonstrates the effectiveness of this method. The experimental results show that the proposed method is able to achieve the maximum absolute error for vignetting estimation of 0.0765 and the relative error for vignetting estimation from different background images of 3.86%.

  14. A HUBBLE DIAGRAM FROM TYPE II SUPERNOVAE BASED SOLELY ON PHOTOMETRY: THE PHOTOMETRIC COLOR METHOD

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    De Jaeger, T.; González-Gaitán, S.; Galbany, L.

    2015-12-20

    We present a Hubble diagram of SNe II using corrected magnitudes derived only from photometry, with no input of spectral information. We use a data set from the Carnegie Supernovae Project I for which optical and near-infrared light curves were obtained. The apparent magnitude is corrected by two observables, one corresponding to the slope of the plateau in the V band and the second a color term. We obtain a dispersion of 0.44 mag using a combination of the (V − i) color and the r band and we are able to reduce the dispersion to 0.39 mag using our goldenmore » sample. A comparison of our photometric color method (PCM) with the standardized candle method (SCM) is also performed. The dispersion obtained for the SCM (which uses both photometric and spectroscopic information) is 0.29 mag, which compares with 0.43 mag from the PCM for the same SN sample. The construction of a photometric Hubble diagram is of high importance in the coming era of large photometric wide-field surveys, which will increase the detection rate of supernovae by orders of magnitude. Such numbers will prohibit spectroscopic follow up in the vast majority of cases, and hence methods must be deployed which can proceed using solely photometric data.« less

  15. Calculation of the acid-base equilibrium constants at the alumina/electrolyte interface from the ph dependence of the adsorption of singly charged ions (Na+, Cl-)

    NASA Astrophysics Data System (ADS)

    Gololobova, E. G.; Gorichev, I. G.; Lainer, Yu. A.; Skvortsova, I. V.

    2011-05-01

    A procedure was proposed for the calculation of the acid-base equilibrium constants at an alumina/electrolyte interface from experimental data on the adsorption of singly charged ions (Na+, Cl-) at various pH values. The calculated constants (p K {1/0}= 4.1, p K {2/0}= 11.9, p K {3/0}= 8.3, and p K {4/0}= 7.7) are shown to agree with the values obtained from an experimental pH dependence of the electrokinetic potential and the results of potentiometric titration of Al2O3 suspensions.

  16. Prophylactic Therapy for Hereditary Angioedema.

    PubMed

    Longhurst, Hilary; Zinser, Emily

    2017-08-01

    Long-term prophylaxis is needed in many patients with hereditary angioedema and poses many challenges. Attenuated androgens are effective in many but are limited by side effect profiles. There is less evidence for efficacy of tranexamic acid and progestagens; however, the small side effect profile makes tranexamic acid an option for prophylaxis in children and progestagens an option for women. C1 inhibitor is beneficial, but at present requires intravenous delivery and may need dose titration for maximum efficacy. Short-term prophylaxis should be considered for all procedures. New therapies are promising in overcoming many problems encountered with current options for long-term prophylaxis. Copyright © 2017 Elsevier Inc. All rights reserved.

  17. The Dynamic Photometric Stereo Method Using a Multi-Tap CMOS Image Sensor.

    PubMed

    Yoda, Takuya; Nagahara, Hajime; Taniguchi, Rin-Ichiro; Kagawa, Keiichiro; Yasutomi, Keita; Kawahito, Shoji

    2018-03-05

    The photometric stereo method enables estimation of surface normals from images that have been captured using different but known lighting directions. The classical photometric stereo method requires at least three images to determine the normals in a given scene. However, this method cannot be applied to dynamic scenes because it is assumed that the scene remains static while the required images are captured. In this work, we present a dynamic photometric stereo method for estimation of the surface normals in a dynamic scene. We use a multi-tap complementary metal-oxide-semiconductor (CMOS) image sensor to capture the input images required for the proposed photometric stereo method. This image sensor can divide the electrons from the photodiode from a single pixel into the different taps of the exposures and can thus capture multiple images under different lighting conditions with almost identical timing. We implemented a camera lighting system and created a software application to enable estimation of the normal map in real time. We also evaluated the accuracy of the estimated surface normals and demonstrated that our proposed method can estimate the surface normals of dynamic scenes.

  18. Photometric Study of Fourteen Low-mass Binaries

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Korda, D.; Zasche, P.; Wolf, M.

    2017-07-01

    New CCD photometric observations of fourteen short-period low-mass eclipsing binaries (LMBs) in the photometric filters I, R, and V were used for a light curve analysis. A discrepancy remains between observed radii and those derived from the theoretical modeling for LMBs, in general. Mass calibration of all observed LMBs was performed using only the photometric indices. The light curve modeling of these selected systems was completed, yielding the new derived masses and radii for both components. We compared these systems with the compilation of other known double-lined LMB systems with uncertainties of masses and radii less then 5%, which includesmore » 66 components of binaries where both spectroscopy and photometry were combined together. All of our systems are circular short-period binaries, and for some of them, the photospheric spots were also used. A purely photometric study of the light curves without spectroscopy seems unable to achieve high enough precision and accuracy in the masses and radii to act as meaningful test of the M–R relation for low-mass stars.« less

  19. GALAXY ZOO MORPHOLOGY AND PHOTOMETRIC REDSHIFTS IN THE SLOAN DIGITAL SKY SURVEY

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Way, M. J.

    It has recently been demonstrated that one can accurately derive galaxy morphology from particular primary and secondary isophotal shape estimates in the Sloan Digital Sky Survey (SDSS) imaging catalog. This was accomplished by applying Machine Learning techniques to the Galaxy Zoo morphology catalog. Using the broad bandpass photometry of the SDSS in combination with precise knowledge of galaxy morphology should help in estimating more accurate photometric redshifts for galaxies. Using the Galaxy Zoo separation for spirals and ellipticals in combination with SDSS photometry we attempt to calculate photometric redshifts. In the best case we find that the root-mean-square error formore » luminous red galaxies classified as ellipticals is as low as 0.0118. Given these promising results we believe better photometric redshift estimates for all galaxies in the SDSS ({approx}350 million) will be feasible if researchers can also leverage their derived morphologies via Machine Learning. These initial results look to be promising for those interested in estimating weak lensing, baryonic acoustic oscillation, and other fields dependent upon accurate photometric redshifts.« less

  20. WINGS: A WIde-field Nearby Galaxy-cluster Survey. II. Deep optical photometry of 77 nearby clusters

    NASA Astrophysics Data System (ADS)

    Varela, J.; D'Onofrio, M.; Marmo, C.; Fasano, G.; Bettoni, D.; Cava, A.; Couch, W. J.; Dressler, A.; Kjærgaard, P.; Moles, M.; Pignatelli, E.; Poggianti, B. M.; Valentinuzzi, T.

    2009-04-01

    Context: This is the second paper of a series devoted to the WIde Field Nearby Galaxy-cluster Survey (WINGS). WINGS is a long term project which is gathering wide-field, multi-band imaging and spectroscopy of galaxies in a complete sample of 77 X-ray selected, nearby clusters (0.04 < z < 0.07) located far from the galactic plane (|b|≥ 20°). The main goal of this project is to establish a local reference for evolutionary studies of galaxies and galaxy clusters. Aims: This paper presents the optical (B,V) photometric catalogs of the WINGS sample and describes the procedures followed to construct them. We have paid special care to correctly treat the large extended galaxies (which includes the brightest cluster galaxies) and the reduction of the influence of the bright halos of very bright stars. Methods: We have constructed photometric catalogs based on wide-field images in B and V bands using SExtractor. Photometry has been performed on images in which large galaxies and halos of bright stars were removed after modeling them with elliptical isophotes. Results: We publish deep optical photometric catalogs (90% complete at V ~ 21.7, which translates to ˜ M^*_V+6 at mean redshift), giving positions, geometrical parameters, and several total and aperture magnitudes for all the objects detected. For each field we have produced three catalogs containing galaxies, stars and objects of “unknown” classification (~6%). From simulations we found that the uncertainty of our photometry is quite dependent of the light profile of the objects with stars having the most robust photometry and de Vaucouleurs profiles showing higher uncertainties and also an additional bias of ~-0.2^m. The star/galaxy classification of the bright objects (V < 20) was checked visually making negligible the fraction of misclassified objects. For fainter objects, we found that simulations do not provide reliable estimates of the possible misclassification and therefore we have compared our data with that from deep counts of galaxies and star counts from models of our Galaxy. Both sets turned out to be consistent with our data within ~5% (in the ratio galaxies/total) up to V ~ 24. Finally, we remark that the application of our special procedure to remove large halos improves the photometry of the large galaxies in our sample with respect to the use of blind automatic procedures and increases (~16%) the detection rate of objects projected onto them. Based on observations taken at the Issac Newton Telescope (2.5 m-INT) sited at Roque de los Muchachos (La Palma, Spain), and the MPG/ESO-2.2 m Telescope sited at La Silla (Chile). Appendices are only available in electronic form at http://www.aanda.org Catalog is only available in electronic form at the CDS via anonymous ftp to cdsarc.u-strasbg.fr (130.79.128.5) or via http://cdsweb.u-strasbg.fr/cgi-bin/qcat?J/A+A/497/667

  1. Toward an efficient Photometric Supernova Classifier

    NASA Astrophysics Data System (ADS)

    McClain, Bradley

    2018-01-01

    The Sloan Digital Sky Survey Supernova Survey (SDSS) discovered more than 1,000 Type Ia Supernovae, yet less than half of these have spectroscopic measurements. As wide-field imaging telescopes such as The Dark Energy Survey (DES) and the Panoramic Survey Telescope and Rapid Response System (Pan-STARRS) discover more supernovae, the need for accurate and computationally cheap photometric classifiers increases. My goal is to use a photometric classification algorithm based on Sncosmo, a python library for supernova cosmology analysis, to reclassify previously identified Hubble SN and other non-spectroscopically confirmed surveys. My results will be compared to other photometric classifiers such as PSNID and STARDUST. In the near future, I expect to have the algorithm validated with simulated data, optimized for efficiency, and applied with high performance computing to real data.

  2. Cannabinoids concentration variability in cannabis olive oil galenic preparations.

    PubMed

    Carcieri, Chiara; Tomasello, Cristina; Simiele, Marco; De Nicolò, Amedeo; Avataneo, Valeria; Canzoneri, Luca; Cusato, Jessica; Di Perri, Giovanni; D'Avolio, Antonio

    2018-01-01

    Knowledge of the exact concentration of active compounds in galenic preparations is crucial to be able to ensure their quality and to properly administer the prescribed dose. Currently, the need for titration of extracts is still debated. Considering this, together with the absence of a standard preparation method, the aim of this study was to evaluate cannabinoids concentrations variability in galenic olive oil extracts, to evaluate the interlot and interlaboratory variability in the extraction yield and in the preparation composition. Two hundred and one extracts (123 (61.2%) from Bedrocan ® , 54 (26.9%) from Bediol ® , 11 (5.5%) from Bedrolite ® , and 13 (6.5%) from mixed preparations) were analysed by liquid chromatography coupled with tandem mass spectrometry, quantifying cannabinoids (THC, CBD, THCA, CBDA and CBN) concentrations. The RSD% of THC and CBD concentrations resulted higher than 50%. Specifically for Bedrocan ® , Bediol ® , Bedrolite ® (5 g/50 ml), these were THC 82%, THC 53% and CBD 91%, THC 58% and CBD 59%, respectively. The median extraction yields were greater than 75% for all preparations. Our results highlighted a wide variability in THC and CBD concentrations that justify the need for titration and opens further questions about other pharmaceutical preparations without regulatory indication for this procedure. © 2017 Royal Pharmaceutical Society.

  3. Mesoporous Carbons With Self-Assembled High-Activity Surfaces (PREPRINT)

    DTIC Science & Technology

    2006-07-07

    temperature-programmed desorption, and potentiometric titrations . Journal of Colloid and Interface Science 2001; 240: 252–258. [40] Rotkin SV, Gogotsi Y...selected carbon samples were treated with nitric acid and the total acid site density determined by base titration [32-34 Boehm 1994; Boehm 2002; 32...washed thoroughly using distilled/deionized water, and dried in the oven. For the titration , 50 mg of HNO3-treated carbon powder was added to 20 ml

  4. High-Molecular Compounds (Selected Articles).

    DTIC Science & Technology

    1987-10-15

    us ions The method of potentiometric titration in dimethylformamide was used to study the structure of macro molecular chain of copolymers based on...macromolecular chain we used the method of potential metric titration . The objects of the study uere alpha chloroacrylic acid (KO)K) in monomer...homopolymer, and copolymer (with methylmethacrylate) form 131. I e d* r. I%0 I 0 12 # z Curves of potential metric titration of solutions of copolymers of KjAK

  5. The Thermodynamics of the Carbonate System in Seawater,

    DTIC Science & Technology

    1979-03-08

    ionization of water at various water by potentiometric titration . Deep-Sea Res. 17, temperatures from molal volume data. J. Soln. Chem. 737-750. 1... titration alkalinity, AT, givcn by not available at low salinities and molal volume cal- A, = [HCO/] + 2[CO2-] + [B(OH-] culations (MILLERO et al...used to characterize obtained by a computer titration improves, pH the parameters of the carbonate system in seawater. measurements should be made. This

  6. The Velocity of Sound in Sea Water at Zero Depth

    DTIC Science & Technology

    1952-06-11

    the Woods Hole Oceanographic Institution. Toward the end of this investigation a potentiometric titration with the Beckman automatic titratcr and a...Interferon eter as soon as received, and at Intervals throughout the investigation. Ch!orlnitie3 were determined by the Mohr method of AgNOi titration ...chlorinity of each of the solutions was actually determined by Mohr titration in the sar.? manner as the chiorinities of the original samples. The

  7. Process for Assessing the Stability of HAN (Hydroxylammonium Nitrate)-Based Liquid Propellants

    DTIC Science & Technology

    1989-02-09

    Scholz, Guidelines by Messrs. Riedel - de Haen for Titration according to the Karl Fischer Method ), 3. Auflage/3rd Edition 1982 /22/ JANDER; G. and... Potentiometric determination of the equivalence point is the most suitable method /15/. Time is saved by using automatically recording titration 33...propellant. The water content of liquid propellants on the basis of HAN according to Fig. 6 can be determined directly by Karl Fischer titration. This

  8. Photometric measurements of solar irradiance variations due to sunspots

    NASA Technical Reports Server (NTRS)

    Chapman, G. A.; Herzog, A. D.; Laico, D. E.; Lawrence, J. K.; Templer, M. S.

    1989-01-01

    A photometric telescope constructed to obtain photometric sunspot areas and deficits on a daily basis is described. Data from this Cartesian full disk telescope (CFDT) are analyzed with attention given to the period between June 4 and June 17, 1985 because of the availability of overlapping sunspot area and irradiance deficit data from high-resolution digital spectroheliograms made with the San Fernando Observatory 28 cm vacuum solar telescope and spectroheliograph. The CFDT sunspot deficits suggest a substantial irradiance contribution from faculae and active region plage.

  9. Study of the Effects of Photometric Geometry on Spectral Reflectance Measurements

    NASA Technical Reports Server (NTRS)

    Helfenstein, Paul

    1998-01-01

    The objective of this research is to investigate how the spectrophotometric properties of planetary surface materials depend on photometric geometry by refining and applying radiative transfer theory to data obtained from spacecraft and telescope observations of planetary surfaces, studies of laboratory analogs, and computer simulations. The goal is to perfect the physical interpretation of photometric parameters in the context of planetary surface geological properties and processes. The purpose of this report is to document the research achievements associated with this study.

  10. Intensity measurement of automotive headlamps using a photometric vision system

    NASA Astrophysics Data System (ADS)

    Patel, Balvant; Cruz, Jose; Perry, David L.; Himebaugh, Frederic G.

    1996-01-01

    Requirements for automotive head lamp luminous intensity tests are introduced. The rationale for developing a non-goniometric photometric test system is discussed. The design of the Ford photometric vision system (FPVS) is presented, including hardware, software, calibration, and system use. Directional intensity plots and regulatory test results obtained from the system are compared to corresponding results obtained from a Ford goniometric test system. Sources of error for the vision system and goniometer are discussed. Directions for new work are identified.

  11. [Determination of aluminium in flour foods with photometric method].

    PubMed

    Ma, Lan; Zhao, Xin; Zhou, Shuang; Yang, Dajin

    2012-05-01

    To establish a determination method for aluminium in flour foods with photometric method. After samples being treated with microwave digestion and wet digestion, aluminium in staple flour foods was determined by photometric method. There was a good linearity of the result in the range of 0.25 - 5.0 microg/ml aluminium, r = 0.9998; limit of detection (LOD) : 2.3 ng/ml; limit of quantitation (LOQ) : 7 ng/ml. This method of determining aluminium in flour foods is simple, rapid and reliable.

  12. Biogeochemical conversion of sulfur species in saline lakes of Steppe Altai

    NASA Astrophysics Data System (ADS)

    Borzenko, Svetlana V.; Kolpakova, Marina N.; Shvartsev, Stepan L.; Isupov, Vitaly P.

    2017-08-01

    The aim of the present research is to identify the main mechanisms of sulfur behavior in saline lakes in the course of time and followed transformations in their chemical composition. The influence of water on chemical composition of biochemical processes involved in decomposition of organic matter was determined by the study of behavior of reduced forms of sulfur in lakes. The determination of reduced forms of sulfur was carried out by successive transfer of each form of sulfur to hydrogen sulfide followed by photometric measurements. The other chemical components were determined by standard methods (atomic absorption, potentiometric method, titration method and others). The salt lakes of the Altai steppe were studied in summer season 2013-2015. Analysis of the chemical composition of the saline lakes of Altai Krai has shown that carbonate-, hydrocarbonate- and chloride ions dominate among anions; sodium is main cation; sulfates are found in subordinate amounts. Reduced forms of sulfur occur everywhere: hydrogen and hydrosulfide sulfur S2- prevail in the bottom sediments; its derivative—elemental S0—prevails in the lakes water. The second important species in water of soda lakes is hydrosulfide sulfur S2-, and in chloride lakes is thiosulfate sulfur S2O3 2- . The lag in the accumulation of sulfates in soda lakes in comparison to chloride lakes can be explained by their bacterial reduction, followed by the formation and deposition of iron sulfides in sediments. In chloride lakes gypsum is a predominantly barrier for sulfates.

  13. Dark Energy Survey Year 1 Results: Redshift distributions of the weak lensing source galaxies

    NASA Astrophysics Data System (ADS)

    Hoyle, B.; Gruen, D.; Bernstein, G. M.; Rau, M. M.; De Vicente, J.; Hartley, W. G.; Gaztanaga, E.; DeRose, J.; Troxel, M. A.; Davis, C.; Alarcon, A.; MacCrann, N.; Prat, J.; Sánchez, C.; Sheldon, E.; Wechsler, R. H.; Asorey, J.; Becker, M. R.; Bonnett, C.; Carnero Rosell, A.; Carollo, D.; Carrasco Kind, M.; Castander, F. J.; Cawthon, R.; Chang, C.; Childress, M.; Davis, T. M.; Drlica-Wagner, A.; Gatti, M.; Glazebrook, K.; Gschwend, J.; Hinton, S. R.; Hoormann, J. K.; Kim, A. G.; King, A.; Kuehn, K.; Lewis, G.; Lidman, C.; Lin, H.; Macaulay, E.; Maia, M. A. G.; Martini, P.; Mudd, D.; Möller, A.; Nichol, R. C.; Ogando, R. L. C.; Rollins, R. P.; Roodman, A.; Ross, A. J.; Rozo, E.; Rykoff, E. S.; Samuroff, S.; Sevilla-Noarbe, I.; Sharp, R.; Sommer, N. E.; Tucker, B. E.; Uddin, S. A.; Varga, T. N.; Vielzeuf, P.; Yuan, F.; Zhang, B.; Abbott, T. M. C.; Abdalla, F. B.; Allam, S.; Annis, J.; Bechtol, K.; Benoit-Lévy, A.; Bertin, E.; Brooks, D.; Buckley-Geer, E.; Burke, D. L.; Busha, M. T.; Capozzi, D.; Carretero, J.; Crocce, M.; D'Andrea, C. B.; da Costa, L. N.; DePoy, D. L.; Desai, S.; Diehl, H. T.; Doel, P.; Eifler, T. F.; Estrada, J.; Evrard, A. E.; Fernandez, E.; Flaugher, B.; Fosalba, P.; Frieman, J.; García-Bellido, J.; Gerdes, D. W.; Giannantonio, T.; Goldstein, D. A.; Gruendl, R. A.; Gutierrez, G.; Honscheid, K.; James, D. J.; Jarvis, M.; Jeltema, T.; Johnson, M. W. G.; Johnson, M. D.; Kirk, D.; Krause, E.; Kuhlmann, S.; Kuropatkin, N.; Lahav, O.; Li, T. S.; Lima, M.; March, M.; Marshall, J. L.; Melchior, P.; Menanteau, F.; Miquel, R.; Nord, B.; O'Neill, C. R.; Plazas, A. A.; Romer, A. K.; Sako, M.; Sanchez, E.; Santiago, B.; Scarpine, V.; Schindler, R.; Schubnell, M.; Smith, M.; Smith, R. C.; Soares-Santos, M.; Sobreira, F.; Suchyta, E.; Swanson, M. E. C.; Tarle, G.; Thomas, D.; Tucker, D. L.; Vikram, V.; Walker, A. R.; Weller, J.; Wester, W.; Wolf, R. C.; Yanny, B.; Zuntz, J.; DES Collaboration

    2018-04-01

    We describe the derivation and validation of redshift distribution estimates and their uncertainties for the populations of galaxies used as weak lensing sources in the Dark Energy Survey (DES) Year 1 cosmological analyses. The Bayesian Photometric Redshift (BPZ) code is used to assign galaxies to four redshift bins between z ≈ 0.2 and ≈1.3, and to produce initial estimates of the lensing-weighted redshift distributions n^i_PZ(z)∝ dn^i/dz for members of bin i. Accurate determination of cosmological parameters depends critically on knowledge of ni but is insensitive to bin assignments or redshift errors for individual galaxies. The cosmological analyses allow for shifts n^i(z)=n^i_PZ(z-Δ z^i) to correct the mean redshift of ni(z) for biases in n^i_PZ. The Δzi are constrained by comparison of independently estimated 30-band photometric redshifts of galaxies in the COSMOS field to BPZ estimates made from the DES griz fluxes, for a sample matched in fluxes, pre-seeing size, and lensing weight to the DES weak-lensing sources. In companion papers, the Δzi of the three lowest redshift bins are further constrained by the angular clustering of the source galaxies around red galaxies with secure photometric redshifts at 0.15 < z < 0.9. This paper details the BPZ and COSMOS procedures, and demonstrates that the cosmological inference is insensitive to details of the ni(z) beyond the choice of Δzi. The clustering and COSMOS validation methods produce consistent estimates of Δzi in the bins where both can be applied, with combined uncertainties of σ _{Δ z^i}=0.015, 0.013, 0.011, and 0.022 in the four bins. Repeating the photo-z proceedure instead using the Directional Neighborhood Fitting (DNF) algorithm, or using the ni(z) estimated from the matched sample in COSMOS, yields no discernible difference in cosmological inferences.

  14. Galileo photometry of Apollo landing sites

    NASA Technical Reports Server (NTRS)

    Helfenstein, P.; Veverka, J.; Head, James W.; Pieters, C.; Pratt, S.; Mustard, J.; Klaasen, K.; Neukum, G.; Hoffmann, H.; Jaumann, R.

    1993-01-01

    As of December 1992, the Galileo spacecraft performed its second and final flyby (EM2), of the Earth-Moon system, during which it acquired Solid State Imaging (SSI) camera images of the lunar surface suitable for photometric analysis using Hapke's, photometric model. These images, together with those from the first flyby (EM1) in December 1989, provide observations of all of the Apollo landing sites over a wide range of photometric geometries and at eight broadband filter wavelengths ranging from 0.41 micron to 0.99 micron. We have completed a preliminary photometric analysis of Apollo landing sites visible in EM1 images and developed a new strategy for a more complete analysis of the combined EM1 and EM2 data sets in conjunction with telescopic observations and spectrogoniometric measurements of returned lunar samples. No existing single data set, whether from spacecraft flyby, telescopic observation, or laboratory analysis of returned samples, describes completely the light scattering behavior of a particular location on the Moon at all angles of incidence (i), emission (e), and phase angles (a). Earthbased telescopic observations of particular lunar sites provide good coverage of incidence nad phase angles, but their range in emission angle is limited to only a few degrees because of the Moon's synchronous rotation. Spacecraft flyby observations from Galileo are now available for specific lunar features at many photometric geometries unobtainable from Earth; however, this data set lacks coverage at very small phase angles (a less than 13 deg) important for distinguishing the well-known 'opposition effect'. Spectrogoniometric measurements from returned lunar samples can provide photometric coverage at almost any geometry; however, mechanical properties of prepared particulate laboratory samples, such as particle compaction and macroscopic roughness, likely differ from those on the lunar surface. In this study, we have developed methods for the simultaneous analysis of all three types of data: we combine Galileo and telescopic observations to obtain the most complete coverage with photometric geometry, and use spectrogoniometric observations of lunar soils to help distinguish the photometric effects of macroscopic roughness from those caused by particle phase function behavior (i.e., the directional scattering properties of regolith particles).

  15. Cost-effectiveness of ezetimibe coadministration in statin-treated patients not at cholesterol goal: application to Germany, Spain and Norway.

    PubMed

    Cook, John R; Yin, Don; Alemao, Evo; Davies, Glenn; Krobot, Karl J; Veltri, Enrico; Lipka, Leslie; Badia, Xavier

    2004-01-01

    Despite the growing use of statins, many hypercholesterolaemic patients fail to reach their lipid goal and remain at elevated risk of coronary heart disease (CHD). Alternative treatment strategies, such as ezetimibe coadministration and statin titration, can help patients achieve greater lipid control, and thereby lower their CHD risk. But is it cost effective to more aggressively lower cholesterol levels across a broad range of current statin users? Using a decision-analytic model based on epidemiological and clinical trials data, we project the lifetime benefit and cost of alternative lipid-lowering treatment strategies for CHD and non-CHD diabetic patients in Germany, Spain and Norway. It is projected that from 40% to 76% of these patients who have failed to reach their lipid goal with their current statin treatment will be able to reach their goal with ezetimibe coadministration; this represents a gain of up to an additional absolute 14% who will be able to reach their goal compared with a 'titrate to goal' strategy where patients are titrated in order to reach their lipid goal (up to the maximum approved dose). For CHD patients, the estimated incremental cost-effectiveness ratio for ezetimibe coadministration is under Euro 18 000 per life-year gained (Euro/LYG) and 26 000 Euro/LYG compared with strategies based on the observed titration rates and the aggressive 'titrate to goal' strategy, respectively; for non-CHD diabetic patients, these ratios are under 26 000 Euro/LYG and 48 000 Euro/LYG for ezetimibe coadministration compared with the two titration strategies. Compared with statin titration, ezetimibe coadministration is projected to be cost effective in the populations and countries studied.

  16. Evaluation of synergistic effects of resynchronization therapy and a β-blocker up-titration strategy based on a predefined patient-management program: the RESTORE study.

    PubMed

    Palmisano, Pietro; Ammendola, Ernesto; D'Onofrio, Antonio; Accogli, Michele; Calò, Leonardo; Ruocco, Antonio; Rapacciuolo, Antonio; Del Giorno, Giuseppe; Bianchi, Valter; Malacrida, Maurizio; Valsecchi, Sergio; Gronda, Edoardo

    2015-01-01

    Prior studies have suggested that a substantial number of eligible heart failure (HF) patients fail to receive β-blocker therapy, or receive it at a suboptimal dose. The aim of this study is to assess the benefit of a predefined management program designed for β-blocker up-titration, evaluating the synergistic effect of cardiac resynchronization therapy (CRT) and β-blockers in a HF population. The Resynchronization Therapy and β-Blocker Titration (RESTORE) study is a prospective, case-control, multicenter cohort study designed to test the hypothesis that a β-blocker up-titration strategy based on a predefined management program maximizes the beneficial effect of CRT, increasing the number of patients reaching the target dose of β-blockers and improving their clinical outcome. All study patients receive an implantable defibrillator for CRT delivery in accordance with current guidelines. Enrollments started in December 2011 and are scheduled to end in December 2014. Approximately 250 consecutive patients will be prospectively enrolled in 6 Italian centers and followed up for 24 months after implantation. The primary endpoint is to demonstrate that CRT may allow titration of β-blockers until the optimal dose, or at least to the effective dose, in patients with HF. This study might provide important information about the benefit of a predefined management program for β-blocker up-titration in patients receiving CRT. Moreover, assessment of health-care utilization and the consumption of resources will allow estimating the potential utility of remote monitoring by means of an automated telemedicine system in facilitating the titration of β-blockers in comparison with a standard in-hospital approach. © 2015 Wiley Periodicals, Inc.

  17. Clinical Outcomes of Continuation of Metformin Titration Instructions with Electronic Prescribing.

    PubMed

    Delate, Thomas; Rader, Nathan; Rawlings, Julia E; Smith, Karen; Herner, Sheryl J

    2015-06-01

    Anecdotal evidence suggests that metformin titration instructions are not being updated and refill requests are approved without modification of the titration instructions such that the titration instructions is continued for patients newly initiated on metformin. This was a retrospective cohort analysis of adult patients who received newly initiated metformin pharmacotherapy. Patients were followed from their initial metformin purchase through two subsequent metformin refill purchases. Outcomes, including the 3-year incidence rate of patients with at least one set of continued titration instructions and proportions of patients with at least one gastrointestinal adverse effect (AE) and those with an elevated glucose measurement at follow-up, were assessed during the time period between patients' second and third metformin purchases. Analyses were performed comparing the exposure (i.e., patients with continued instructions) group to the control (i.e., patients without continued instructions) group. The exposure group had a higher mean age and chronic disease score but lower metformin starting dose than the control group (all p < 0.05). The 3-year incidence rate of patients with at least one continuation of titration instructions was 60.3 % (95 % CI 58.3-62.3). Gastrointestinal AEs were rare with equivalent proportions of patients in each group experiencing an event (p > 0.05). Control patients (48.7 % of patients with a measurement) were more likely to have had poorly controlled glucose than exposure patients (35.7 % of patients with a measurement) (p < 0.001). A high rate of continuation of titration instructions for patients newly initiated on metformin was observed; however, such continuation did not negatively affect clinical outcomes.

  18. Barriers to Beta-Blocker Use and Up-Titration Among Patients with Heart Failure with Reduced Ejection Fraction.

    PubMed

    Levitan, Emily B; Van Dyke, Melissa K; Loop, Matthew Shane; O'Beirne, Ronan; Safford, Monika M

    2017-12-01

    For patients with heart failure with reduced ejection fraction (HFrEF), guidelines recommend use of beta-blockers with gradual up-titration. However, many patients with HFrEF do not use beta-blockers and up-titration is rare. Our purpose was to identify and rank barriers to beta-blocker use and up-titration from the perspective of primary care physicians. We conducted 4 moderated, structured group discussions among 19 primary care physicians using the nominal group technique; 16 participants also completed a survey. Participants generated lists of barriers to beta-blocker use and up-titration among patients with HFrEF. Each participant had six votes with three votes assigned to the item ranked most important, two to the second most important item, and one to the third most important item. Investigators characterized items into themes. The percentage of available votes was calculated for each theme. Fifteen of 16 participating primary care physicians who completed the survey reported that management of beta-blockers was their responsibility. Treatment/side effects, particularly hypotension, were identified as the most important barrier for beta-blocker use (72% of available votes) followed by polypharmacy (11%), healthcare system barriers (10%), and comorbidities (6%). Barriers to up-titration included treatment/side effects (49% of available votes), patient communication/buy-in (21%), polypharmacy (13%), and healthcare system barriers (8%). Many barriers to guideline concordant use of beta-blockers among patients with HFrEF identified by primary care providers are not readily modifiable. Addressing these barriers may require development, testing, and dissemination of protocols for beta-blocker initiation and up-titration that are safe and appropriate in primary care.

  19. Predicting prolonged dose titration in patients starting warfarin.

    PubMed

    Finkelman, Brian S; French, Benjamin; Bershaw, Luanne; Brensinger, Colleen M; Streiff, Michael B; Epstein, Andrew E; Kimmel, Stephen E

    2016-11-01

    Patients initiating warfarin therapy generally experience a dose-titration period of weeks to months, during which time they are at higher risk of both thromboembolic and bleeding events. Accurate prediction of prolonged dose titration could help clinicians determine which patients might be better treated by alternative anticoagulants that, while more costly, do not require dose titration. A prediction model was derived in a prospective cohort of patients starting warfarin (n = 390), using Cox regression, and validated in an external cohort (n = 663) from a later time period. Prolonged dose titration was defined as a dose-titration period >12 weeks. Predictor variables were selected using a modified best subsets algorithm, using leave-one-out cross-validation to reduce overfitting. The final model had five variables: warfarin indication, insurance status, number of doctor's visits in the previous year, smoking status, and heart failure. The area under the ROC curve (AUC) in the derivation cohort was 0.66 (95%CI 0.60, 0.74) using leave-one-out cross-validation, but only 0.59 (95%CI 0.54, 0.64) in the external validation cohort, and varied across clinics. Including genetic factors in the model did not improve the area under the ROC curve (0.59; 95%CI 0.54, 0.65). Relative utility curves indicated that the model was unlikely to provide a clinically meaningful benefit compared with no prediction. Our results suggest that prolonged dose titration cannot be accurately predicted in warfarin patients using traditional clinical, social, and genetic predictors, and that accurate prediction will need to accommodate heterogeneities across clinical sites and over time. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  20. Entire-Dataset Analysis of NMR Fast-Exchange Titration Spectra: A Mg2+ Titration Analysis for HIV-1 Ribonuclease H Domain.

    PubMed

    Karki, Ichhuk; Christen, Martin T; Spiriti, Justin; Slack, Ryan L; Oda, Masayuki; Kanaori, Kenji; Zuckerman, Daniel M; Ishima, Rieko

    2016-12-15

    This article communicates our study to elucidate the molecular determinants of weak Mg 2+ interaction with the ribonuclease H (RNH) domain of HIV-1 reverse transcriptase in solution. As the interaction is weak (a ligand-dissociation constant >1 mM), nonspecific Mg 2+ interaction with the protein or interaction of the protein with other solutes that are present in the buffer solution can confound the observed Mg 2+ -titration data. To investigate these indirect effects, we monitored changes in the chemical shifts of backbone amides of RNH by recording NMR 1 H- 15 N heteronuclear single-quantum coherence spectra upon titration of Mg 2+ into an RNH solution. We performed the titration under three different conditions: (1) in the absence of NaCl, (2) in the presence of 50 mM NaCl, and (3) at a constant 160 mM Cl - concentration. Careful analysis of these three sets of titration data, along with molecular dynamics simulation data of RNH with Na + and Cl - ions, demonstrates two characteristic phenomena distinct from the specific Mg 2+ interaction with the active site: (1) weak interaction of Mg 2+ , as a salt, with the substrate-handle region of the protein and (2) overall apparent lower Mg 2+ affinity in the absence of NaCl compared to that in the presence of 50 mM NaCl. A possible explanation may be that the titrated MgCl 2 is consumed as a salt and interacts with RNH in the absence of NaCl. In addition, our data suggest that Na + increases the kinetic rate of the specific Mg 2+ interaction at the active site of RNH. Taken together, our study provides biophysical insight into the mechanism of weak metal interaction on a protein.

Top