Sample records for physiological monitoring protocol

  1. An intelligent health monitoring system using radio-frequency identification technology.

    PubMed

    Lai, Yeong-Lin; Chen, Chin-Ling; Chang, Ching-Hisang; Hsu, Chih-Yu; Lai, Yeong-Kang; Tseng, Kuo-Kun; Chen, Chih-Cheng; Zheng, Chun-Yi

    2015-01-01

    Long-term care (LTC) for the elderly has become extremely important in recent years. It is necessary for the different physiological monitoring systems to be integrated on the same interface to help oversee and manage the elderly's needs. This paper presents a novel health monitoring system for LTC services using radio-frequency identification (RFID) technology. Dual-band RFID protocols were included in the system, in which the high-frequency (HF) band of 13.56 MHz was used to identify individuals and the microwave band of 2.45 GHz was used to monitor physiological information. Distinct physiological data, including oxyhemoglobin saturation by pulse oximetry (SpO2), blood pressure, blood sugar, electrocardiogram (ECG) readings, body temperature, and respiration rate, were monitored by various biosensors. The intelligent RFID health monitoring system provided the features of the real-time acquisition of biomedical signals and the identification of personal information pertaining to the elderly and patients in nursing homes.

  2. Physiological response of rats to delivery of helium and xenon: implications for hyperpolarized noble gas imaging

    NASA Technical Reports Server (NTRS)

    Ramirez, M. P.; Sigaloff, K. C.; Kubatina, L. V.; Donahue, M. A.; Venkatesh, A. K.; Albert, M. S.; ALbert, M. S. (Principal Investigator)

    2000-01-01

    The physiological effects of various hyperpolarized helium and xenon MRI-compatible breathing protocols were investigated in 17 Sprague-Dawley rats, by continuous monitoring of blood oxygen saturation, heart rate, EKG, temperature and endotracheal pressure. The protocols included alternating breaths of pure noble gas and oxygen, continuous breaths of pure noble gas, breath-holds of pure noble gas for varying durations, and helium breath-holds preceded by two helium rinses. Alternate-breath protocols up to 128 breaths caused a decrease in oxygen saturation level of less than 5% for either helium or xenon, whereas 16 continuous-breaths caused a 31.5% +/- 2.3% decrease in oxygen saturation for helium and a 30.7% +/- 1. 3% decrease for xenon. Breath-hold protocols up to 25 s did not cause the oxygen saturation to fall below 90% for either of the noble gases. Oxygen saturation values below 90% are considered pathological. At 30 s of breath-hold, the blood oxygen saturation dropped precipitously to 82% +/- 0.6% for helium, and to 76.5% +/- 7. 4% for xenon. Breath-holds longer than 10 s preceded by pre-rinses caused oxygen saturation to drop below 90%. These findings demonstrate the need for standardized noble gas inhalation procedures that have been carefully tested, and for continuous physiological monitoring to ensure the safety of the subject. We find short breath-hold and alternate-breath protocols to be safe procedures for use in hyperpolarized noble gas MRI experiments. Copyright 2000 John Wiley & Sons, Ltd.

  3. A novel Smart Routing Protocol for remote health monitoring in Medical Wireless Networks.

    PubMed

    Sundararajan, T V P; Sumithra, M G; Maheswar, R

    2014-01-01

    In a Medical Wireless Network (MWN), sensors constantly monitor patient's physiological condition and movement. Inter-MWN communications are set up between the Patient Server and one or more Centralized Coordinators. However, MWNs require protocols with little energy consumption and the self-organizing attribute perceived in ad-hoc networks. The proposed Smart Routing Protocol (SRP) selects only the nodes with a higher residual energy and lower traffic density for routing. This approach enhances cooperation among the nodes of a Mobile Ad Hoc Network. Consequently, SRP produces better results than the existing protocols, namely Conditional Min-Max Battery Cost Routing, Min-Max Battery Cost Routing and AdHoc On-demand Distance Vector in terms of network parameters. The performance of the erstwhile schemes for routing protocols is evaluated using the network simulator Qualnet v 4.5.

  4. Vasomotor Symptoms Monitoring with a Commercial Activity Tracking Watch

    DTIC Science & Technology

    2017-12-31

    volunteers wearing physiological monitors. The study protocol and written consent form were...available, but similar devices with EDA/GSR sensors are available. Vasomotor symptoms started disrupting the sleep of a woman volunteer on...November 23, 2015, calling attention to their occurrence. After November 23, 2015, the volunteer started personally logging the occurrence of

  5. Comparing the effects of minimal handling protocols on the physiological parameters of preterm infants receiving exogenous surfactant therapy

    PubMed Central

    Cabral, Laura A.; Velloso, Marcelo

    2014-01-01

    Background The practice of minimal handling is recommended for preterm infants (PTIs). However, few studies have investigated the effects of this practice among these infants or the time needed to ensure greater physiological stability, especially after exogenous surfactant treatments. Objective The current study compared the effects of two protocols of minimal handling on the physiological variables of PTIs after surfactant therapy. Method An exploratory prospective observational study was performed with 40 PTIs weighing less than 1,500 g. The infants were divided into two groups and monitored for 72 hours. One group received the standard minimal handling procedure during the first 12 hours after surfactant therapy; the other group (i.e., the modified group) received minimal handling within 72 hours after surfactant therapy. Infant heart rate (HR), oxygen saturation, body temperature, and the adverse events associated with changes to these variables were monitored every 10 minutes. Results Significant between-group differences were not found with regard to the occurrence of the adverse events associated with physiological changes (p>0.05). Conclusion The practice of minimal handling among very low birth weight infants did not alter their physiological stability when performed either 12 or 72 hours after surfactant therapy. PMID:24839044

  6. The promise of wearable sensors and ecological momentary assessment measures for dynamical systems modeling in adolescents: a feasibility and acceptability study.

    PubMed

    Brannon, Erin E; Cushing, Christopher C; Crick, Christopher J; Mitchell, Tarrah B

    2016-12-01

    Intervention development can be accelerated by using wearable sensors and ecological momentary assessment (EMA) to study how behaviors change within a person. The purpose of this study was to determine the feasibility and acceptability of a novel, intensive EMA method for assessing physiology, behavior, and psychosocial variables utilizing two objective sensors and a mobile application (app). Adolescents (n = 20) enrolled in a 20-day EMA protocol. Participants wore a physiological monitor and an accelerometer that measured sleep and physical activity and completed four surveys per day on an app. Participants provided approximately 81 % of the expected survey data. Participants were compliant to the wrist-worn accelerometer (75.3 %), which is a feasible measurement of physical activity/sleep (74.1 % complete data). The data capture (47.8 %) and compliance (70.28 %) with the physiological monitor were lower than other study variables. The findings support the use of an intensive assessment protocol to study real-time relationships between biopsychosocial variables and health behaviors.

  7. Detection of essential hypertension with physiological signals from wearable devices.

    PubMed

    Ghosh, Arindam; Torres, Juan Manuel Mayor; Danieli, Morena; Riccardi, Giuseppe

    2015-08-01

    Early detection of essential hypertension can support the prevention of cardiovascular disease, a leading cause of death. The traditional method of identification of hypertension involves periodic blood pressure measurement using brachial cuff-based measurement devices. While these devices are non-invasive, they require manual setup for each measurement and they are not suitable for continuous monitoring. Research has shown that physiological signals such as Heart Rate Variability, which is a measure of the cardiac autonomic activity, is correlated with blood pressure. Wearable devices capable of measuring physiological signals such as Heart Rate, Galvanic Skin Response, Skin Temperature have recently become ubiquitous. However, these signals are not accurate and are prone to noise due to different artifacts. In this paper a) we present a data collection protocol for continuous non-invasive monitoring of physiological signals from wearable devices; b) we implement signal processing techniques for signal estimation; c) we explore how the continuous monitoring of these physiological signals can be used to identify hypertensive patients; d) We conduct a pilot study with a group of normotensive and hypertensive patients to test our techniques. We show that physiological signals extracted from wearable devices can distinguish between these two groups with high accuracy.

  8. Ultra Low Power Signal Oriented Approach for Wireless Health Monitoring

    PubMed Central

    Marinkovic, Stevan; Popovici, Emanuel

    2012-01-01

    In recent years there is growing pressure on the medical sector to reduce costs while maintaining or even improving the quality of care. A potential solution to this problem is real time and/or remote patient monitoring by using mobile devices. To achieve this, medical sensors with wireless communication, computational and energy harvesting capabilities are networked on, or in, the human body forming what is commonly called a Wireless Body Area Network (WBAN). We present the implementation of a novel Wake Up Receiver (WUR) in the context of standardised wireless protocols, in a signal-oriented WBAN environment and present a novel protocol intended for wireless health monitoring (WhMAC). WhMAC is a TDMA-based protocol with very low power consumption. It utilises WBAN-specific features and a novel ultra low power wake up receiver technology, to achieve flexible and at the same time very low power wireless data transfer of physiological signals. As the main application is in the medical domain, or personal health monitoring, the protocol caters for different types of medical sensors. We define four sensor modes, in which the sensors can transmit data, depending on the sensor type and emergency level. A full power dissipation model is provided for the protocol, with individual hardware and application parameters. Finally, an example application shows the reduction in the power consumption for different data monitoring scenarios. PMID:22969379

  9. Ultra low power signal oriented approach for wireless health monitoring.

    PubMed

    Marinkovic, Stevan; Popovici, Emanuel

    2012-01-01

    In recent years there is growing pressure on the medical sector to reduce costs while maintaining or even improving the quality of care. A potential solution to this problem is real time and/or remote patient monitoring by using mobile devices. To achieve this, medical sensors with wireless communication, computational and energy harvesting capabilities are networked on, or in, the human body forming what is commonly called a Wireless Body Area Network (WBAN). We present the implementation of a novel Wake Up Receiver (WUR) in the context of standardised wireless protocols, in a signal-oriented WBAN environment and present a novel protocol intended for wireless health monitoring (WhMAC). WhMAC is a TDMA-based protocol with very low power consumption. It utilises WBAN-specific features and a novel ultra low power wake up receiver technology, to achieve flexible and at the same time very low power wireless data transfer of physiological signals. As the main application is in the medical domain, or personal health monitoring, the protocol caters for different types of medical sensors. We define four sensor modes, in which the sensors can transmit data, depending on the sensor type and emergency level. A full power dissipation model is provided for the protocol, with individual hardware and application parameters. Finally, an example application shows the reduction in the power consumption for different data monitoring scenarios.

  10. Representativeness comparisons of nurse and computer charting of heart rate across nursing-intensity protocols.

    PubMed

    Luna, Jorge M; Yip, Natalie; Pivovarov, Rimma; Vawdrey, David K

    2016-08-01

    Clinical teams in acute inpatient settings can greatly benefit from automated charting technologies that continuously monitor patient vital status. NewYork-Presbyterian has designed and developed a real-time patient monitoring system that integrates vital signs sensors, networking, and electronic health records, to allow for automatic charting of patient status. We evaluate the representativeness (a combination of agreement, safety and timing) of a core vital sign across nursing intensity care protocols for preliminary feasibility assessment. Our findings suggest an automated way of summarizing heart rate provides representation of true heart rate status and can facilitate alternatives approaches to burdensome manual nurse charting of physiological parameters.

  11. A Survey on Wireless Body Area Networks for eHealthcare Systems in Residential Environments

    PubMed Central

    Ghamari, Mohammad; Janko, Balazs; Sherratt, R. Simon; Harwin, William; Piechockic, Robert; Soltanpur, Cinna

    2016-01-01

    Current progress in wearable and implanted health monitoring technologies has strong potential to alter the future of healthcare services by enabling ubiquitous monitoring of patients. A typical health monitoring system consists of a network of wearable or implanted sensors that constantly monitor physiological parameters. Collected data are relayed using existing wireless communication protocols to a base station for additional processing. This article provides researchers with information to compare the existing low-power communication technologies that can potentially support the rapid development and deployment of WBAN systems, and mainly focuses on remote monitoring of elderly or chronically ill patients in residential environments. PMID:27338377

  12. A Survey on Wireless Body Area Networks for eHealthcare Systems in Residential Environments.

    PubMed

    Ghamari, Mohammad; Janko, Balazs; Sherratt, R Simon; Harwin, William; Piechockic, Robert; Soltanpur, Cinna

    2016-06-07

    Current progress in wearable and implanted health monitoring technologies has strong potential to alter the future of healthcare services by enabling ubiquitous monitoring of patients. A typical health monitoring system consists of a network of wearable or implanted sensors that constantly monitor physiological parameters. Collected data are relayed using existing wireless communication protocols to a base station for additional processing. This article provides researchers with information to compare the existing low-power communication technologies that can potentially support the rapid development and deployment of WBAN systems, and mainly focuses on remote monitoring of elderly or chronically ill patients in residential environments.

  13. Effects of physiological and/or disease status on the response of postpartum dairy cows to synchronization of estrus using an intravaginal progesterone device.

    PubMed

    McNally, Julie C; Crowe, Mark A; Roche, James F; Beltman, Marijke E

    2014-12-01

    Progesterone treatments are used to increase submission rates in postpartum dairy cows; however, in many cases the protocol is used as a blanket therapy for all cows without regard for physiological or disease state. The objective of this study was to identify the physiological or disease classes of cows that respond well (or not) to synchronization of estrus via progesterone. Dairy cows (n = 402) were monitored peri and postpartum to establish their physiological or disease status. Animals were classified as having negative energy balance, clinical lameness, uterine infection (UI), anovulatory anestrus, high somatic cell counts, and healthy (H). Blood samples were collected at five different time points and analyzed for metabolites. All animals received an 8-day controlled internal drug release protocol, which included GnRH at insertion and PGF2α the day before removal. Response to the protocol was determined by visual observation of estrus synchronization. Conception rate was determined by ultrasonography between Days 32 and 35 after artificial insemination. Animals without UI were 1.9 times more likely to respond and two times more likely to be confirmed pregnant than those with UI. There was no relationship between negative energy balance and clinical lameness in the visual estrous response, but both conditions were associated with reduced conception rates. Dairy cows in anovulatory anestrus responded successfully to the protocol in both estrous response and conception rates. High glutathione peroxidase concentrations had a positive effect on conception rates, whereas high non-esterified fatty acids and beta-hydroxybutyrate had a negative effect on the estrous response. In conclusion, disease and physiological states of dairy cows determined the response to progesterone-based synchronization. The more disease or physiological problems the cows had, the lower the estrous response and conception rates; cows with these problems were not ideal candidates for synchronization. Both anestrus and healthy dairy cows were good responders to progesterone-based synchronization. Copyright © 2014 Elsevier Inc. All rights reserved.

  14. The Role of Multimodal Invasive Monitoring in Acute Traumatic Brain Injury.

    PubMed

    Lazaridis, Christos; Robertson, Claudia S

    2016-10-01

    This article reviews the role of modalities that directly monitor brain parenchyma in patients with severe traumatic brain injury. The physiology monitored involves compartmental and perfusion pressures, tissue oxygenation and metabolism, quantitative blood flow, pressure autoregulation, and electrophysiology. There are several proposed roles for this multimodality monitoring, such as to track, prevent, and treat the cascade of secondary brain injury; monitor the neurologically injured patient; integrate various data into a composite, patient-specific, and dynamic picture; apply protocolized, pathophysiology-driven intensive care; use as a prognostic marker; and understand pathophysiologic mechanisms involved in secondary brain injury to develop preventive and abortive therapies, and to inform future clinical trials. Copyright © 2016 Elsevier Inc. All rights reserved.

  15. Performance assessment of a glucose control protocol in septic patients with an automated intermittent plasma glucose monitoring device.

    PubMed

    Umbrello, M; Salice, V; Spanu, P; Formenti, P; Barassi, A; Melzi d'Eril, G V; Iapichino, G

    2014-10-01

    The optimal level and modality of glucose control in critically ill patients is still debated. A protocolized approach and the use of nearly-continuous technologies are recommended to manage hyperglycemia, hypoglycemia and glycemic variability. We recently proposed a pato-physiology-based glucose control protocol which takes into account patient glucose/carbohydrate intake and insulin resistance. Aim of the present investigation was to assess the performance of our protocol with an automated intermittent plasma glucose monitoring device (OptiScanner™ 5000). OptiScanner™ was used in 6 septic patients, providing glucose measurement every 15' from a side-port of an indwelling central venous catheter. Target level of glucose was 80-150 mg/dL. Insulin infusion and kcal with nutritional support were also recorded. 6 septic patients were studied for 319 h (1277 measurements); 58 [45-65] hours for each patient (measurements/patient: 231 [172-265]). Blood glucose was at target for 93 [90-98]% of study time. Mean plasma glucose was 126 ± 11 mg/dL. Only 3 hypoglycemic episodes (78, 78, 69 mg/dL) were recorded. Glucose variability was limited: plasma glucose coefficient of variation was 11.7 ± 4.0% and plasma glucose standard deviation was 14.3 ± 5.5 mg/dL. The local glucose control protocol achieved satisfactory glucose control in septic patients along with a high degree of safeness. Automated intermittent plasma glucose monitoring seemed useful to assess the performance of the protocol. Copyright © 2013 Elsevier Ltd and European Society for Clinical Nutrition and Metabolism. All rights reserved.

  16. Physiological complexity of acute traumatic brain injury in patients treated with a brain oxygen protocol: utility of symbolic regression in predictive modeling of a dynamical system.

    PubMed

    Narotam, Pradeep K; Morrison, John F; Schmidt, Michael D; Nathoo, Narendra

    2014-04-01

    Predictive modeling of emergent behavior, inherent to complex physiological systems, requires the analysis of large complex clinical data streams currently being generated in the intensive care unit. Brain tissue oxygen protocols have yielded outcome benefits in traumatic brain injury (TBI), but the critical physiological thresholds for low brain oxygen have not been established for a dynamical patho-physiological system. High frequency, multi-modal clinical data sets from 29 patients with severe TBI who underwent multi-modality neuro-clinical care monitoring and treatment with a brain oxygen protocol were analyzed. The inter-relationship between acute physiological parameters was determined using symbolic regression (SR) as the computational framework. The mean patient age was 44.4±15 with a mean admission GCS of 6.6±3.9. Sixty-three percent sustained motor vehicle accidents and the most common pathology was intra-cerebral hemorrhage (50%). Hospital discharge mortality was 21%, poor outcome occurred in 24% of patients, and good outcome occurred in 56% of patients. Criticality for low brain oxygen was intracranial pressure (ICP) ≥22.8 mm Hg, for mortality at ICP≥37.1 mm Hg. The upper therapeutic threshold for cerebral perfusion pressure (CPP) was 75 mm Hg. Eubaric hyperoxia significantly impacted partial pressure of oxygen in brain tissue (PbtO2) at all ICP levels. Optimal brain temperature (Tbr) was 34-35°C, with an adverse effect when Tbr≥38°C. Survivors clustered at [Formula: see text] Hg vs. non-survivors [Formula: see text] 18 mm Hg. There were two mortality clusters for ICP: High ICP/low PbtO2 and low ICP/low PbtO2. Survivors maintained PbtO2 at all ranges of mean arterial pressure in contrast to non-survivors. The final SR equation for cerebral oxygenation is: [Formula: see text]. The SR-model of acute TBI advances new physiological thresholds or boundary conditions for acute TBI management: PbtO2≥25 mmHg; ICP≤22 mmHg; CPP≈60-75 mmHg; and Tbr≈34-37°C. SR is congruous with the emerging field of complexity science in the modeling of dynamical physiological systems, especially during pathophysiological states. The SR model of TBI is generalizable to known physical laws. This increase in entropy reduces uncertainty and improves predictive capacity. SR is an appropriate computational framework to enable future smart monitoring devices.

  17. A new wireless system for decentralised measurement of physiological parameters from shake flasks

    PubMed Central

    Vasala, Antti; Panula, Johanna; Bollók, Monika; Illmann, Lutz; Hälsig, Christian; Neubauer, Peter

    2006-01-01

    Background Shake flasks are widely used because of their low price and simple handling. Many researcher are, however, not aware of the physiological consequences of oxygen limitation and substrate overflow metabolism that occur in shake flasks. Availability of a wireless measuring system brings the possibilities for quality control and design of cultivation conditions. Results Here we present a new wireless solution for the measurement of pH and oxygen from shake flasks with standard sensors, which allows data transmission over a distance of more than 100 metres in laboratory environments. This new system was applied to monitoring of cultivation conditions in shake flasks. The at-time monitoring of the growth conditions became possible by simple means. Here we demonstrate that with typical protocols E. coli shake flask cultures run into severe oxygen limitation and the medium is strongly acidified. Additionally the strength of the new system is demonstrated by continuous monitoring of the oxygen level in methanol-fed Pichia pastoris shake flask cultures, which allows the optimisation of substrate feeding for preventing starvation or methanol overfeed. 40 % higher cell density was obtained by preventing starvation phases which occur in standard shake flask protocols by adding methanol when the respiration activity decreased in the cultures. Conclusion The here introduced wireless system can read parallel sensor data over long distances from shake flasks that are under vigorous shaking in cultivation rooms or closed incubators. The presented technology allows centralised monitoring of decentralised targets. It is useful for the monitoring of pH and dissolved oxygen in shake flask cultures. It is not limited to standard sensors, but can be easily adopted to new types of sensors and measurement places (e.g., new sensor points in large-scale bioreactors). PMID:16504107

  18. The Development of Real-Time Physiological Monitoring and Training Software for Remote Applications

    NASA Technical Reports Server (NTRS)

    2005-01-01

    Autogenic Feedback Training Exercise (AFTE) is an protocol and technology developed by Dr. Patricia Cowings and her associates at NASA Ames Research Center as a means to facilitate astronaut adaptation to space and exposure to the microgravity. AFTE is a training method which involves teaching subjects to voluntarily control several of their own physiological responses to environmental stressors. As the procedures matured, the training program was expanded to determine if technology developed to facilitate astronaut adaptation to space would be valuable in treating patients suffering from autonomic and vestibular pathologies and symptomatic relief from nausea and/or blood pressure control anomalies such as hypo- or hypertension. The present study, performed in conjunction with Morehouse School of Medicine, Biomedical Engineering at The University of Akron and NASA Ames Research Center has demonstrated that this technology can be successfully applied over vast distances. The specific purpose of this research was to develop a PC based system which could handle processing of twenty channels of acquired physiological data in addition to the necessary duplex communication protocols that would, for example, permit a patient in Atlanta, GA to be trained by a clinician stationed in San Jose, CA. Sixteen channels of physiological data and 20 channels of processed data are included.

  19. Physiology in conservation translocations.

    PubMed

    Tarszisz, Esther; Dickman, Christopher R; Munn, Adam J

    2014-01-01

    Conservation translocations aim to restore species to their indigenous ranges, protect populations from threats and/or reinstate ecosystem functions. They are particularly important for the conservation and management of rare and threatened species. Despite tremendous efforts and advancement in recent years, animal conservation translocations generally have variable success, and the reasons for this are often uncertain. We suggest that when little is known about the physiology and wellbeing of individuals either before or after release, it will be difficult to determine their likelihood of survival, and this could limit advancements in the science of translocations for conservation. In this regard, we argue that physiology offers novel approaches that could substantially improve translocations and associated practices. As a discipline, it is apparent that physiology may be undervalued, perhaps because of the invasive nature of some physiological measurement techniques (e.g. sampling body fluids, surgical implantation). We examined 232 publications that dealt with translocations of terrestrial vertebrates and aquatic mammals and, defining 'success' as high or low, determined how many of these studies explicitly incorporated physiological aspects into their protocols and monitoring. From this review, it is apparent that physiological evaluation before and after animal releases could progress and improve translocation/reintroduction successes. We propose a suite of physiological measures, in addition to animal health indices, for assisting conservation translocations over the short term and also for longer term post-release monitoring. Perhaps most importantly, we argue that the incorporation of physiological assessments of animals at all stages of translocation can have important welfare implications by helping to reduce the total number of animals used. Physiological indicators can also help to refine conservation translocation methods. These approaches fall under a new paradigm that we term 'translocation physiology' and represent an important sub-discipline within conservation physiology generally.

  20. A mobile system for assessment of physiological response to posture transitions.

    PubMed

    Jovanov, Emil; Milosevic, Mladen; Milenković, Aleksandar

    2013-01-01

    Posture changes initiate a dynamic physiological response that can be used as an indicator of the overall health status. We introduce an inconspicuous mobile wellness monitoring system (imWell) that continuously assesses the dynamic physiological response to posture transitions during activities of daily living. imWell utilizes a Zephyr BioHarness 3 physiological monitor that continually reports heart activity and physical activity via Bluetooth to a personal device (e.g. smartphone). The personal device processes the reported activity data in real-time to recognize posture transitions from the accelerometer data and to characterize dynamic heart response to posture changes. It annotates, logs, and uploads the heart activity data to our mHealth server. In this paper we present algorithms for detection of posture transitions and heart activity characterization during a sit-to-stand transition. The proposed system was tested on seven healthy subjects performing a predefined protocol. The total average and standard deviation for sit-to-stand transition time is 2.7 ± 0.69 s, resulting in the change of heart rate of 27.36 ± 9.30 bpm (from 63.3 ± 9.02 bpm to 90.66 ± 10.09 bpm).

  1. Development of the Aviation Stress Protocol--Simulation and Performance, Physiological, and Biochemical Monitoring Systems: Phase I. Assessment of Cardiovascular Function after Exposure to the Aviation Stress Protocol- Simulation. The Relationship between Stress-Related Metabolites and Disqualifying Pathology in Air Traffic Control Personnel

    DTIC Science & Technology

    1978-02-01

    Category Diai2osis Occurrence Gastrointestinal Gastric Ulcer 15.4 Duodenal Ulcer 15.4 Peptic Ulcer 15.4 Gastritis 15.4 Gall Bladder 7.7 Other 30.7...session, subjects were given a cardiovascular evaluation. During each 3-h test session, the subjects perfor -med four different combinations of tasks of...related" disease. As shown in Table 1, the principal subcategories of that disease relate to ulceration of the stomach and duodenum. Ulcers have long

  2. Treating Panic Disorder Hypnotically.

    PubMed

    Reid, David B

    2017-10-01

    A hypnosis protocol for treating panic disorder is provided. The implementation of this protocol is demonstrated through a case example involving the successful treatment of a 28-year-old firefighter presenting with a 4-month history of near-daily panic attacks. Core principles associated with this protocol include: (1) Elementary education about the physiology of panic; (2) A review of primary factors contributing to the evolution and manifestation of panic; (3) Encouragement of physical activity; (4) Utilization of hypnosis applications; and (5) Monitoring and measuring progress evidenced by a reduction in the frequency and intensity of panic attacks. Six years after his last hypnosis session, "Jason," the once panicked firefighter returned to my office for concerns unrelated to panic, and reported that he remained panic-free, retained his job, and was twice promoted.

  3. On-Line Analysis of Physiologic and Neurobehavioral Variables During Long-Duration Space Missions

    NASA Technical Reports Server (NTRS)

    Brown, Emery N.

    1999-01-01

    The goal of this project is to develop reliable statistical algorithms for on-line analysis of physiologic and neurobehavioral variables monitored during long-duration space missions. Maintenance of physiologic and neurobehavioral homeostasis during long-duration space missions is crucial for ensuring optimal crew performance. If countermeasures are not applied, alterations in homeostasis will occur in nearly all-physiologic systems. During such missions data from most of these systems will be either continually and/or continuously monitored. Therefore, if these data can be analyzed as they are acquired and the status of these systems can be continually assessed, then once alterations are detected, appropriate countermeasures can be applied to correct them. One of the most important physiologic systems in which to maintain homeostasis during long-duration missions is the circadian system. To detect and treat alterations in circadian physiology during long duration space missions requires development of: 1) a ground-based protocol to assess the status of the circadian system under the light-dark environment in which crews in space will typically work; and 2) appropriate statistical methods to make this assessment. The protocol in Project 1, Circadian Entrainment, Sleep-Wake Regulation and Neurobehavioral will study human volunteers under the simulated light-dark environment of long-duration space missions. Therefore, we propose to develop statistical models to characterize in near real time circadian and neurobehavioral physiology under these conditions. The specific aims of this project are to test the hypotheses that: 1) Dynamic statistical methods based on the Kronauer model of the human circadian system can be developed to estimate circadian phase, period, amplitude from core-temperature data collected under simulated light- dark conditions of long-duration space missions. 2) Analytic formulae and numerical algorithms can be developed to compute the error in the estimates of circadian phase, period and amplitude determined from the data in Specific Aim 1. 3) Statistical models can detect reliably in near real- time (daily) significant alternations in the circadian physiology of individual subjects by analyzing the circadian and neurobehavioral data collected in Project 1. 4) Criteria can be developed using the Kronauer model and the recently developed Jewett model of cognitive -performance and subjective alertness to define altered circadian and neurobehavioral physiology and to set conditions for immediate administration of countermeasures.

  4. Physiology in conservation translocations

    PubMed Central

    Tarszisz, Esther; Dickman, Christopher R.; Munn, Adam J.

    2014-01-01

    Conservation translocations aim to restore species to their indigenous ranges, protect populations from threats and/or reinstate ecosystem functions. They are particularly important for the conservation and management of rare and threatened species. Despite tremendous efforts and advancement in recent years, animal conservation translocations generally have variable success, and the reasons for this are often uncertain. We suggest that when little is known about the physiology and wellbeing of individuals either before or after release, it will be difficult to determine their likelihood of survival, and this could limit advancements in the science of translocations for conservation. In this regard, we argue that physiology offers novel approaches that could substantially improve translocations and associated practices. As a discipline, it is apparent that physiology may be undervalued, perhaps because of the invasive nature of some physiological measurement techniques (e.g. sampling body fluids, surgical implantation). We examined 232 publications that dealt with translocations of terrestrial vertebrates and aquatic mammals and, defining ‘success’ as high or low, determined how many of these studies explicitly incorporated physiological aspects into their protocols and monitoring. From this review, it is apparent that physiological evaluation before and after animal releases could progress and improve translocation/reintroduction successes. We propose a suite of physiological measures, in addition to animal health indices, for assisting conservation translocations over the short term and also for longer term post-release monitoring. Perhaps most importantly, we argue that the incorporation of physiological assessments of animals at all stages of translocation can have important welfare implications by helping to reduce the total number of animals used. Physiological indicators can also help to refine conservation translocation methods. These approaches fall under a new paradigm that we term ‘translocation physiology’ and represent an important sub-discipline within conservation physiology generally. PMID:27293675

  5. Wearable Performance Devices in Sports Medicine.

    PubMed

    Li, Ryan T; Kling, Scott R; Salata, Michael J; Cupp, Sean A; Sheehan, Joseph; Voos, James E

    2016-01-01

    Wearable performance devices and sensors are becoming more readily available to the general population and athletic teams. Advances in technology have allowed individual endurance athletes, sports teams, and physicians to monitor functional movements, workloads, and biometric markers to maximize performance and minimize injury. Movement sensors include pedometers, accelerometers/gyroscopes, and global positioning satellite (GPS) devices. Physiologic sensors include heart rate monitors, sleep monitors, temperature sensors, and integrated sensors. The purpose of this review is to familiarize health care professionals and team physicians with the various available types of wearable sensors, discuss their current utilization, and present future applications in sports medicine. Data were obtained from peer-reviewed literature through a search of the PubMed database. Included studies searched development, outcomes, and validation of wearable performance devices such as GPS, accelerometers, and physiologic monitors in sports. Clinical review. Level 4. Wearable sensors provide a method of monitoring real-time physiologic and movement parameters during training and competitive sports. These parameters can be used to detect position-specific patterns in movement, design more efficient sports-specific training programs for performance optimization, and screen for potential causes of injury. More recent advances in movement sensors have improved accuracy in detecting high-acceleration movements during competitive sports. Wearable devices are valuable instruments for the improvement of sports performance. Evidence for use of these devices in professional sports is still limited. Future developments are needed to establish training protocols using data from wearable devices. © 2015 The Author(s).

  6. Wearable Performance Devices in Sports Medicine

    PubMed Central

    Li, Ryan T.; Kling, Scott R.; Salata, Michael J.; Cupp, Sean A.; Sheehan, Joseph; Voos, James E.

    2016-01-01

    Context: Wearable performance devices and sensors are becoming more readily available to the general population and athletic teams. Advances in technology have allowed individual endurance athletes, sports teams, and physicians to monitor functional movements, workloads, and biometric markers to maximize performance and minimize injury. Movement sensors include pedometers, accelerometers/gyroscopes, and global positioning satellite (GPS) devices. Physiologic sensors include heart rate monitors, sleep monitors, temperature sensors, and integrated sensors. The purpose of this review is to familiarize health care professionals and team physicians with the various available types of wearable sensors, discuss their current utilization, and present future applications in sports medicine. Evidence Acquisition: Data were obtained from peer-reviewed literature through a search of the PubMed database. Included studies searched development, outcomes, and validation of wearable performance devices such as GPS, accelerometers, and physiologic monitors in sports. Study Design: Clinical review. Level of Evidence: Level 4. Results: Wearable sensors provide a method of monitoring real-time physiologic and movement parameters during training and competitive sports. These parameters can be used to detect position-specific patterns in movement, design more efficient sports-specific training programs for performance optimization, and screen for potential causes of injury. More recent advances in movement sensors have improved accuracy in detecting high-acceleration movements during competitive sports. Conclusion: Wearable devices are valuable instruments for the improvement of sports performance. Evidence for use of these devices in professional sports is still limited. Future developments are needed to establish training protocols using data from wearable devices. PMID:26733594

  7. Physiology, intervention, and outcome: three critical questions about cerebral tissue oxygen saturation monitoring.

    PubMed

    Meng, Lingzhong; Gruenbaum, Shaun E; Dai, Feng; Wang, Tianlong

    2018-05-01

    The balance between cerebral tissue oxygen consumption and supply can be continuously assessed by cerebral tissue oxygen saturation (SctO2) monitor. A construct consisting of three sequential questions, targeting the physiology monitored, the intervention implemented, and the outcomes affected, is proposed to critically appraise this monitor. The impact of the SctO2-guided care on patient outcome was examined through a systematic literature search and meta-analysis. We concluded that the physiology monitored by SctO2 is robust and dynamic, fragile (prone to derangement), and adversely consequential when deranged. The inter-individual variability of SctO2 measurement advocates for an intervention threshold based on a relative, not absolute, change. The intra-individual variability has multiple determinants which is the foundation of intervention. A variety of therapeutic options are available; however, none are 100% efficacious in treating cerebral dys-oxygenation. The therapeutic efficacy likely depends on both an appropriate differential diagnosis and the functional status of the regulatory mechanisms of cerebral blood flow. Meta-analysis based on five randomized controlled trials suggested a reduced incidence of early postoperative cognitive decline after major surgeries (RR= 0.53; 95% CI: 0.33-0.87; I2 =82%; P=0.01). However, its effects on other neurocognitive outcomes remain unclear. These results need to be interpreted with caution due to the high risks of bias. Quality RCTs based on improved intervention protocols and standardized outcome assessment are warranted in the future.

  8. Efficient security mechanisms for mHealth applications using wireless body sensor networks.

    PubMed

    Sahoo, Prasan Kumar

    2012-01-01

    Recent technological advances in wireless communications and physiological sensing allow miniature, lightweight, ultra-low power, intelligent monitoring devices, which can be integrated into a Wireless Body Sensor Network (WBSN) for health monitoring. Physiological signals of humans such as heartbeats, temperature and pulse can be monitored from a distant location using tiny biomedical wireless sensors. Hence, it is highly essential to combine the ubiquitous computing with mobile health technology using wireless sensors and smart phones to monitor the well-being of chronic patients such as cardiac, Parkinson and epilepsy patients. Since physiological data of a patient are highly sensitive, maintaining its confidentiality is highly essential. Hence, security is a vital research issue in mobile health (mHealth) applications, especially if a patient has an embarrassing disease. In this paper a three tier security architecture for the mHealth application is proposed, in which light weight data confidentiality and authentication protocols are proposed to maintain the privacy of a patient. Moreover, considering the energy and hardware constraints of the wireless body sensors, low complexity data confidential and authentication schemes are designed. Performance evaluation of the proposed architecture shows that they can satisfy the energy and hardware limitations of the sensors and still can maintain the secure fabrics of the wireless body sensor networks. Besides, the proposed schemes can outperform in terms of energy consumption, memory usage and computation time over standard key establishment security scheme.

  9. Efficient Security Mechanisms for mHealth Applications Using Wireless Body Sensor Networks

    PubMed Central

    Sahoo, Prasan Kumar

    2012-01-01

    Recent technological advances in wireless communications and physiological sensing allow miniature, lightweight, ultra-low power, intelligent monitoring devices, which can be integrated into a Wireless Body Sensor Network (WBSN) for health monitoring. Physiological signals of humans such as heartbeats, temperature and pulse can be monitored from a distant location using tiny biomedical wireless sensors. Hence, it is highly essential to combine the ubiquitous computing with mobile health technology using wireless sensors and smart phones to monitor the well-being of chronic patients such as cardiac, Parkinson and epilepsy patients. Since physiological data of a patient are highly sensitive, maintaining its confidentiality is highly essential. Hence, security is a vital research issue in mobile health (mHealth) applications, especially if a patient has an embarrassing disease. In this paper a three tier security architecture for the mHealth application is proposed, in which light weight data confidentiality and authentication protocols are proposed to maintain the privacy of a patient. Moreover, considering the energy and hardware constraints of the wireless body sensors, low complexity data confidential and authentication schemes are designed. Performance evaluation of the proposed architecture shows that they can satisfy the energy and hardware limitations of the sensors and still can maintain the secure fabrics of the wireless body sensor networks. Besides, the proposed schemes can outperform in terms of energy consumption, memory usage and computation time over standard key establishment security scheme. PMID:23112734

  10. A Review of Protocol Implementations and Energy Efficient Cross-Layer Design for Wireless Body Area Networks

    PubMed Central

    Hughes, Laurie; Wang, Xinheng; Chen, Tao

    2012-01-01

    The issues inherent in caring for an ever-increasing aged population has been the subject of endless debate and continues to be a hot topic for political discussion. The use of hospital-based facilities for the monitoring of chronic physiological conditions is expensive and ties up key healthcare professionals. The introduction of wireless sensor devices as part of a Wireless Body Area Network (WBAN) integrated within an overall eHealth solution could bring a step change in the remote management of patient healthcare. Sensor devices small enough to be placed either inside or on the human body can form a vital part of an overall health monitoring network. An effectively designed energy efficient WBAN should have a minimal impact on the mobility and lifestyle of the patient. WBAN technology can be deployed within a hospital, care home environment or in the patient's own home. This study is a review of the existing research in the area of WBAN technology and in particular protocol adaptation and energy efficient cross-layer design. The research reviews the work carried out across various layers of the protocol stack and highlights how the latest research proposes to resolve the various challenges inherent in remote continual healthcare monitoring. PMID:23202185

  11. A WBAN System for Ambulatory Monitoring of Physical Activity and Health Status: Applications and Challenges.

    PubMed

    Jovanov, E; Milenkovic, A; Otto, C; De Groen, P; Johnson, B; Warren, S; Taibi, G

    2005-01-01

    Recent technological advances in sensors, low-power integrated circuits, and wireless communications have enabled the design of low-cost, miniature, lightweight, intelligent physiological sensor platforms that can be seamlessly integrated into a body area network for health monitoring. Wireless body area networks (WBANs) promise unobtrusive ambulatory health monitoring for extended periods of time and near real-time updates of patients' medical records through the Internet. A number of innovative systems for health monitoring have recently been proposed. However, they typically rely on custom communication protocols and hardware designs, lacking generality and flexibility. The lack of standard platforms, system software support, and standards makes these systems expensive. Bulky sensors, high price, and frequent battery changes are all likely to limit user compliance. To address some of these challenges, we prototyped a WBAN utilizing a common off-the-shelf wireless sensor platform with a ZigBee-compliant radio interface and an ultra low-power microcontroller. The standard platform interfaces to custom sensor boards that are equipped with accelerometers for motion monitoring and a bioamplifier for electrocardiogram or electromyogram monitoring. Software modules for on-board processing, communication, and network synchronization have been developed using the TinyOS operating system. Although the initial WBAN prototype targets ambulatory monitoring of user activity, the developed sensors can easily be adapted to monitor other physiological parameters. In this paper, we discuss initial results, implementation challenges, and the need for standardization in this dynamic and promising research field.

  12. An introduction to the Emergency Department Adult Clinical Escalation protocol: ED-ACE.

    PubMed

    Coughlan, Eoin; Geary, Una; Wakai, Abel; O'Sullivan, Ronan; Browne, John; McAuliffe, Eilish; Ward, Marie; McDaid, Fiona; Deasy, Conor

    2017-09-01

    This study demonstrates how a participatory action research approach was used to address the challenge of the early and effective detection of the deteriorating patient in the ED setting. The approach enabled a systematic approach to patient monitoring and escalation of care to be developed to address the wide-ranging spectrum of undifferentiated presentations and the phases of ED care from triage to patient admission. This paper presents a longitudinal patient monitoring system, which aims to provide monitoring and escalation of care, where necessary, of adult patients from triage to admission to hospital in a manner that is feasible in the unique ED environment. An action research approach was taken to designing a longitudinal patient monitoring system appropriate for the ED. While the first draft protocol for post-triage monitoring and escalation was designed by a core research group, six clinical sites were included in iterative cycles of planning, action, reviewing and further planning. Reasons for refining the system at each site were collated and the protocol was adjusted accordingly before commencing the process at the next site. The ED Adult Clinical Escalation longitudinal patient monitoring system (ED-ACE) evolved through iterative cycles of design and testing to include: (1) a monitoring chart for adult patients; (2) a standardised approach to the monitoring and reassessment of patients after triage until they are assessed by a clinician; (3) the ISBAR (I=Identify, S=Situation, B=Background, A=Assessment, R=Recommendation) tool for interprofessional communication relating to clinical escalation; (4) a template for prescribing a patient-specific monitoring plan to be used by treating clinicians to guide patient monitoring from the time the patient is assessed until when they leave the ED and (5) a protocol for clinical escalation prompted by single physiological triggers and clinical concern. This tool offers a link in the 'Chain of Prevention' between the Manchester Triage System and ward-based early warning scores taking account of the importance of standardisation, while being sufficiently adaptable for the unique working environment and patient population in the ED. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  13. Neuronal nitric oxide synthase control mechanisms in the cutaneous vasculature of humans in vivo

    PubMed Central

    Kellogg, Dean L; Zhao, Joan L; Wu, Yubo

    2008-01-01

    The physiological roles of constituitively expressed nitric oxide synthase (NOS) isoforms in humans, in vivo, are unknown. Cutaneous vasodilatation during both central nervous system-mediated, thermoregulatory reflex responses to whole-body heat stress and during peripheral axon reflex-mediated, local responses to skin warming in humans depend on nitric oxide (NO) generation by constituitively expressed NOS of uncertain isoform. We hypothesized that neuronal NOS (nNOS, NOS I) effects cutaneous vasodilatation during whole-body heat stress, but not during local skin warming. We examined the effects of the nNOS inhibitor 7-nitroindazole (7-NI) administered by intradermal microdialysis on vasodilatation induced by whole-body heat stress or local skin warming. Skin blood flow (SkBF) was monitored by laser–Doppler flowmetry (LDF). Blood pressure (MAP) was monitored and cutaneous vascular conductance calculated (CVC = LDF/MAP). In protocol 1, whole-body heat stress was induced with water-perfused suits. In protocol 2, local skin warming was induced through local warming units at LDF sites. At the end of each protocol, 56 mm sodium nitroprusside was perfused at microdialysis sites to raise SkBF to maximal levels for data normalization. 7-NI significantly attenuated CVC increases during whole-body heat stress (P < 0.05), but had no effect on CVC increases induced by local skin warming (P > 0.05). These diametrically opposite effects of 7-NI on two NO-dependent processes verify selective nNOS antagonism, thus proving that the nNOS isoform affects NO increases and hence vasodilatation during centrally mediated, reflex responses to whole-body heat stress, but not during locally mediated, axon reflex responses to local skin warming. We conclude that the constituitively expressed nNOS isoform has distinct physiological roles in cardiovascular control mechanisms in humans, in vivo. PMID:18048451

  14. Measuring Cardiac Autonomic Nervous System (ANS) Activity in Toddlers - Resting and Developmental Challenges.

    PubMed

    Bush, Nicole R; Caron, Zoe K; Blackburn, Katherine S; Alkon, Abbey

    2016-02-25

    The autonomic nervous system (ANS) consists of two branches, the parasympathetic and sympathetic nervous systems, and controls the function of internal organs (e.g., heart rate, respiration, digestion) and responds to everyday and adverse experiences (1). ANS measures in children have been found to be related to behavior problems, emotion regulation, and health (2-7). Therefore, understanding the factors that affect ANS development during early childhood is important. Both branches of the ANS affect young children's cardiovascular responses to stimuli and have been measured noninvasively, via external monitoring equipment, using valid and reliable measures of physiological change (8-11). However, there are few studies of very young children with simultaneous measures of the parasympathetic and sympathetic nervous systems, which limits understanding of the integrated functioning of the two systems. In addition, the majority of existing studies of young children report on infants' resting ANS measures or their reactivity to commonly used mother-child interaction paradigms, and less is known about ANS reactivity to other challenging conditions. We present a study design and standardized protocol for a non-invasive and rapid assessment of cardiac autonomic control in 18 month old children. We describe methods for continuous monitoring of the parasympathetic and sympathetic branches of the ANS under resting and challenge conditions during a home or laboratory visit and provide descriptive findings from our sample of 140 ethnically diverse toddlers using validated equipment and scoring software. Results revealed that this protocol can produce a range of physiological responses to both resting and developmentally challenging conditions, as indicated by changes in heart rate and indices of parasympathetic and sympathetic activity. Individuals demonstrated variability in resting levels, responses to challenges, and challenge reactivity, which provides additional evidence that this protocol is useful for the examination of ANS individual differences for toddlers.

  15. Lightweight and confidential data discovery and dissemination for wireless body area networks.

    PubMed

    He, Daojing; Chan, Sammy; Zhang, Yan; Yang, Haomiao

    2014-03-01

    As a special sensor network, a wireless body area network (WBAN) provides an economical solution to real-time monitoring and reporting of patients' physiological data. After a WBAN is deployed, it is sometimes necessary to disseminate data into the network through wireless links to adjust configuration parameters of body sensors or distribute management commands and queries to sensors. A number of such protocols have been proposed recently, but they all focus on how to ensure reliability and overlook security vulnerabilities. Taking into account the unique features and application requirements of a WBAN, this paper presents the design, implementation, and evaluation of a secure, lightweight, confidential, and denial-of-service-resistant data discovery and dissemination protocol for WBANs to ensure the data items disseminated are not altered or tampered. Based on multiple one-way key hash chains, our protocol provides instantaneous authentication and can tolerate node compromise. Besides the theoretical analysis that demonstrates the security and performance of the proposed protocol, this paper also reports the experimental evaluation of our protocol in a network of resource-limited sensor nodes, which shows its efficiency in practice. In particular, extensive security analysis shows that our protocol is provably secure.

  16. Noninvasive in vivo glucose sensing using an iris based technique

    NASA Astrophysics Data System (ADS)

    Webb, Anthony J.; Cameron, Brent D.

    2011-03-01

    Physiological glucose monitoring is important aspect in the treatment of individuals afflicted with diabetes mellitus. Although invasive techniques for glucose monitoring are widely available, it would be very beneficial to make such measurements in a noninvasive manner. In this study, a New Zealand White (NZW) rabbit animal model was utilized to evaluate a developed iris-based imaging technique for the in vivo measurement of physiological glucose concentration. The animals were anesthetized with isoflurane and an insulin/dextrose protocol was used to control blood glucose concentration. To further help restrict eye movement, a developed ocular fixation device was used. During the experimental time frame, near infrared illuminated iris images were acquired along with corresponding discrete blood glucose measurements taken with a handheld glucometer. Calibration was performed using an image based Partial Least Squares (PLS) technique. Independent validation was also performed to assess model performance along with Clarke Error Grid Analysis (CEGA). Initial validation results were promising and show that a high percentage of the predicted glucose concentrations are within 20% of the reference values.

  17. Physiological and Medical Monitoring for En Route Care of Combat Casualties

    DTIC Science & Technology

    2008-04-01

    Houston, TX 78234-6315; email: victor.convertino@amedd.army.mil. DOI: 10.1097/TA.0b013e31816c82f4 The Journal of TRAUMA Injury, Infection , and...device (A) and the LBNP protocol (B). The Journal of TRAUMA Injury, Infection , and Critical Care S344 April Supplement 2008 negative pressure induces...saturation ( SpO2 ; pulse oximetry), and tissue (muscle) PO2 and pH (near-infrared spectroscopy) in con- scious human subjects exposed to progressive

  18. Pulse oximeter for cyclists in smartphone

    NASA Astrophysics Data System (ADS)

    Martins, L.; Gaidos, O.; dos Santos, I.

    2015-01-01

    The monitoring of cyclists during physical activity is an important factor to improve their performance. We discuss a new approaches based on smartphone for monitoring physiological signal wirelessly for cyclists, using a pulse oximeter sensor attached to the rider's forehead. This paper presents a wireless pulse Oximeter that was developed with a Nellcor's module, which uses the Standard Host Interface Protocol (SHIP) for communication with the Bluetooth module and sends data for a Smartphone with Android O.S. Then these data are shown in the screen: the heartbeat and saturation percentage. The application was created with App Inventor and the data are sent to Google Maps via Twitter. The results demonstrate the possibility of developing a successful prototype.

  19. Intensive care window: real-time monitoring and analysis in the intensive care environment.

    PubMed

    Stylianides, Nikolas; Dikaiakos, Marios D; Gjermundrød, Harald; Panayi, George; Kyprianou, Theodoros

    2011-01-01

    This paper introduces a novel, open-source middleware framework for communication with medical devices and an application using the middleware named intensive care window (ICW). The middleware enables communication with intensive care unit bedside-installed medical devices over standard and proprietary communication protocol stacks. The ICW application facilitates the acquisition of vital signs and physiological parameters exported from patient-attached medical devices and sensors. Moreover, ICW provides runtime and post-analysis procedures for data annotation, data visualization, data query, and analysis. The ICW application can be deployed as a stand-alone solution or in conjunction with existing clinical information systems providing a holistic solution to inpatient medical condition monitoring, early diagnosis, and prognosis.

  20. Analysis of Circadian Leaf Movements.

    PubMed

    Müller, Niels A; Jiménez-Gómez, José M

    2016-01-01

    The circadian clock is a molecular timekeeper that controls a wide variety of biological processes. In plants, clock outputs range from the molecular level, with rhythmic gene expression and metabolite content, to physiological processes such as stomatal conductance or leaf movements. Any of these outputs can be used as markers to monitor the state of the circadian clock. In the model plant Arabidopsis thaliana, much of the current knowledge about the clock has been gained from time course experiments profiling expression of endogenous genes or reporter constructs regulated by the circadian clock. Since these methods require labor-intensive sample preparation or transformation, monitoring leaf movements is an interesting alternative, especially in non-model species and for natural variation studies. Technological improvements both in digital photography and image analysis allow cheap and easy monitoring of circadian leaf movements. In this chapter we present a protocol that uses an autonomous point and shoot camera and free software to monitor circadian leaf movements in tomato.

  1. A Mutual Authentication Framework for Wireless Medical Sensor Networks.

    PubMed

    Srinivas, Jangirala; Mishra, Dheerendra; Mukhopadhyay, Sourav

    2017-05-01

    Wireless medical sensor networks (WMSN) comprise of distributed sensors, which can sense human physiological signs and monitor the health condition of the patient. It is observed that providing privacy to the patient's data is an important issue and can be challenging. The information passing is done via the public channel in WMSN. Thus, the patient, sensitive information can be obtained by eavesdropping or by unauthorized use of handheld devices which the health professionals use in monitoring the patient. Therefore, there is an essential need of restricting the unauthorized access to the patient's medical information. Hence, the efficient authentication scheme for the healthcare applications is needed to preserve the privacy of the patients' vital signs. To ensure secure and authorized communication in WMSN, we design a symmetric key based authentication protocol for WMSN environment. The proposed protocol uses only computationally efficient operations to achieve lightweight attribute. We analyze the security of the proposed protocol. We use a formal security proof algorithm to show the scheme security against known attacks. We also use the Automated Validation of Internet Security Protocols and Applications (AVISPA) simulator to show protocol secure against man-in-the-middle attack and replay attack. Additionally, we adopt an informal analysis to discuss the key attributes of the proposed scheme. From the formal proof of security, we can see that an attacker has a negligible probability of breaking the protocol security. AVISPA simulator also demonstrates the proposed scheme security against active attacks, namely, man-in-the-middle attack and replay attack. Additionally, through the comparison of computational efficiency and security attributes with several recent results, proposed scheme seems to be battered.

  2. Absolute counting of neutrophils in whole blood using flow cytometry.

    PubMed

    Brunck, Marion E G; Andersen, Stacey B; Timmins, Nicholas E; Osborne, Geoffrey W; Nielsen, Lars K

    2014-12-01

    Absolute neutrophil count (ANC) is used clinically to monitor physiological dysfunctions such as myelosuppression or infection. In the research laboratory, ANC is a valuable measure to monitor the evolution of a wide range of disease states in disease models. Flow cytometry (FCM) is a fast, widely used approach to confidently identify thousands of cells within minutes. FCM can be optimised for absolute counting using spiked-in beads or by measuring the sample volume analysed. Here we combine the 1A8 antibody, specific for the mouse granulocyte protein Ly6G, with flow cytometric counting in straightforward FCM assays for mouse ANC, easily implementable in the research laboratory. Volumetric and Trucount™ bead assays were optimized for mouse neutrophils, and ANC values obtained with these protocols were compared to ANC measured by a dual-platform assay using the Orphee Mythic 18 veterinary haematology analyser. The single platform assays were more precise with decreased intra-assay variability compared with ANC obtained using the dual protocol. Defining ANC based on Ly6G expression produces a 15% higher estimate than the dual protocol. Allowing for this difference in ANC definition, the flow cytometry counting assays using Ly6G can be used reliably in the research laboratory to quantify mouse ANC from a small volume of blood. We demonstrate the utility of the volumetric protocol in a time-course study of chemotherapy induced neutropenia using four drug regimens. © 2014 International Society for Advancement of Cytometry.

  3. Aerospace physiology.

    DOT National Transportation Integrated Search

    2004-01-01

    This document defines the protocol standards for the Internet Protocol Suite (IPS), which is commonly referred to as Transmission Control Protocol/Internet Protocol (TCP/IP) protocols used for data communications within the National Airspace System (...

  4. Human performance and physiological function during a 24-hr exposure to 1% bromotrifluoromethane (Halon 1301)

    NASA Technical Reports Server (NTRS)

    Calkins, D. S.; Degioanni, J. J.; Tan, M. N.; Davis, J. R.; Pierson, D. L.

    1993-01-01

    Performance and physiological measurements were obtained from four pairs of men exposed for 24 hr to 1% (10,000 ppm) Halon 1301 (bromotrifluoromethane, CBrF3) and to air with order counterbalanced using a double-blind protocol. Cognitive and motor performance was assessed before, during, and after the exposures using seven scales of the Automated Portable Testing System, which produced 13 measures of performance. Halon inhalation induced decrements in 2 of the 13 measures, but actual and estimated magnitudes of the decrements were no greater than 5% of baseline values. Physiological data were obtained before, during, and after the exposures from clinical chemistry analyses of blood and urine samples, pulmonary function tests, and monitoring of vital signs. Significant change during Halon inhalation was observed for 6 of the 52 variables assessed; however, all physiological values remained within clinically acceptable limits. No cardiovascular effects were noted. This study demonstrated that exposure to 1% Halon 1301 for 24 hr can produce minor disturbance of central nervous system function as assessed by cognitive tasks.

  5. A multi-channel opto-electronic sensor to accurately monitor heart rate against motion artefact during exercise.

    PubMed

    Alzahrani, Abdullah; Hu, Sijung; Azorin-Peris, Vicente; Barrett, Laura; Esliger, Dale; Hayes, Matthew; Akbare, Shafique; Achart, Jérôme; Kuoch, Sylvain

    2015-10-12

    This study presents the use of a multi-channel opto-electronic sensor (OEPS) to effectively monitor critical physiological parameters whilst preventing motion artefact as increasingly demanded by personal healthcare. The aim of this work was to study how to capture the heart rate (HR) efficiently through a well-constructed OEPS and a 3-axis accelerometer with wireless communication. A protocol was designed to incorporate sitting, standing, walking, running and cycling. The datasets collected from these activities were processed to elaborate sport physiological effects. t-test, Bland-Altman Agreement (BAA), and correlation to evaluate the performance of the OEPS were used against Polar and Mio-Alpha HR monitors. No differences in the HR were found between OEPS, and either Polar or Mio-Alpha (both p > 0.05); a strong correlation was found between Polar and OEPS (r: 0.96, p < 0.001); the bias of BAA 0.85 bpm, the standard deviation (SD) 9.20 bpm, and the limits of agreement (LOA) from -17.18 bpm to +18.88 bpm. For the Mio-Alpha and OEPS, a strong correlation was found (r: 0.96, p < 0.001); the bias of BAA 1.63 bpm, SD 8.62 bpm, LOA from -15.27 bpm to +18.58 bpm. These results demonstrate the OEPS to be capable of carrying out real time and remote monitoring of heart rate.

  6. Effects of routine handling and tagging procedures on physiological stress responses in juvenile chinook salmon

    USGS Publications Warehouse

    Sharpe, C.S.; Thompson, D.A.; Blankenship, H.L.; Schreck, C.B.

    1998-01-01

    Juvenile chinook salmon Oncorhynchus tshawytscha were subjected to handling and tagging protocols typical of normal hatchery operations and monitored for their physiological response to stress. Treatments included coded-wire-tagging, counting, ventral fin clipping, adipose fin clipping, and a procedure simulating a pond split. Treatment fish were also subjected to a standardized stress challenge (1 h confinement) to evaluate their ability to deal with disturbances subsequent to a handling or tagging procedure. Circulating levels of cortisol and glucose were used as indicators of stress. Each of the treatments elicited very similar responses among treatment groups. Cortisol increased from resting levels of about 20 ng/mL to about 90 ng/mL by 1 h poststress and returned to near resting levels by 8 h poststress. Glucose levels increased from 50 mg/dL to about 80 mg/dL by 1 h poststress and remained elevated for much of the experiment. The cortisol and glucose responses to the confinement stress did not differ over time or among treatments. However, the confinement stress results do suggest a small but significant cumulative response, indicating small residual effects of the original handling protocols. No deaths were noted among treatment groups.

  7. A Method of High Throughput Monitoring Crop Physiology Using Chlorophyll Fluorescence and Multispectral Imaging.

    PubMed

    Wang, Heng; Qian, Xiangjie; Zhang, Lan; Xu, Sailong; Li, Haifeng; Xia, Xiaojian; Dai, Liankui; Xu, Liang; Yu, Jingquan; Liu, Xu

    2018-01-01

    We present a high throughput crop physiology condition monitoring system and corresponding monitoring method. The monitoring system can perform large-area chlorophyll fluorescence imaging and multispectral imaging. The monitoring method can determine the crop current condition continuously and non-destructively. We choose chlorophyll fluorescence parameters and relative reflectance of multispectral as the indicators of crop physiological status. Using tomato as experiment subject, the typical crop physiological stress, such as drought, nutrition deficiency and plant disease can be distinguished by the monitoring method. Furthermore, we have studied the correlation between the physiological indicators and the degree of stress. Besides realizing the continuous monitoring of crop physiology, the monitoring system and method provide the possibility of machine automatic diagnosis of the plant physiology. Highlights: A newly designed high throughput crop physiology monitoring system and the corresponding monitoring method are described in this study. Different types of stress can induce distinct fluorescence and spectral characteristics, which can be used to evaluate the physiological status of plants.

  8. Hospital protocols for targeted glycemic control: Development, implementation, and models for cost justification.

    PubMed

    Magee, Michelle F

    2007-05-15

    Evolving elements of best practices for providing targeted glycemic control in the hospital setting, clinical performance measurement, basal-bolus plus correction-dose insulin regimens, components of standardized subcutaneous (s.c.) insulin order sets, and strategies for implementation and cost justification of glycemic control initiatives are discussed. Best practices for targeted glycemic control should address accurate documentation of hyperglycemia, initial patient assessment, management plan, target blood glucose range, blood glucose monitoring frequency, maintenance of glycemic control, criteria for glucose management consultations, and standardized insulin order sets and protocols. Establishing clinical performance measures, including desirable processes and outcomes, can help ensure the success of targeted hospital glycemic control initiatives. The basal-bolus plus correction-dose regimen for insulin administration will be used to mimic the normal physiologic pattern of endogenous insulin secretion. Standardized insulin order sets and protocols are being used to minimize the risk of error in insulin therapy. Components of standardized s.c. insulin order sets include specification of the hyperglycemia diagnosis, finger stick blood glucose monitoring frequency and timing, target blood glucose concentration range, cutoff values for excessively high or low blood glucose concentrations that warrant alerting the physician, basal and prandial or nutritional (i.e., bolus) insulin, correction doses, hypoglycemia treatment, and perioperative or procedural dosage adjustments. The endorsement of hospital administrators and key physician and nursing leaders is needed for glycemic control initiatives. Initiatives may be cost justified on the basis of the billings for clinical diabetes management services and/or the return- on-investment accrued to reductions in hospital length of stay, readmissions, and accurate documentation and coding of unrecognized or uncontrolled diabetes, and diabetes complications. Standardized insulin order sets and protocols may minimize risk of insulin errors. The endorsement of these protocols by administrators, physicians, nurses, and pharmacists is also needed for success.

  9. Physiological response of wild dugongs (Dugong dugon) to out-of-water sampling for health assessment

    USGS Publications Warehouse

    Lanyon, Janet M.; Sneath, Helen L.; Long, Trevor; Bonde, Robert K.

    2010-01-01

    The dugong (Dugong dugon) is a vulnerable marine mammal with large populations living in urban Queensland waters. A mark-recapture program for wild dugongs has been ongoing in southern Queensland since 2001. This program has involved capture and in-water sampling of more than 700 dugongs where animals have been held at the water surface for 5 min to be gene-tagged, measured, and biopsied. In 2008, this program expanded to examine more comprehensively body condition, reproductive status, and the health of wild dugongs in Moreton Bay. Using Sea World's research vessel, captured dugongs were lifted onto a boat and sampled out-of-water to obtain accurate body weights and morphometrics, collect blood and urine samples for baseline health parameters and hormone profiles, and ultrasound females for pregnancy status. In all, 30 dugongs, including two pregnant females, were sampled over 10 d and restrained on deck for up to 55 min each while biological data were collected. Each of the dugongs had their basic temperature-heart rate-respiration (THR) monitored throughout their period of handling, following protocols developed for the West Indian manatee (Trichechus manatus). This paper reports on the physiological response of captured dugongs during this out-of-water operation as indicated by their vital signs and the suitability of the manatee monitoring protocols to this related sirenian species. A recommendation is made that the range of vital signs of these wild dugongs be used as benchmark criteria of normal parameters for other studies that intend to sample dugongs out-of-water.

  10. Smart Vest: wearable multi-parameter remote physiological monitoring system.

    PubMed

    Pandian, P S; Mohanavelu, K; Safeer, K P; Kotresh, T M; Shakunthala, D T; Gopal, Parvati; Padaki, V C

    2008-05-01

    The wearable physiological monitoring system is a washable shirt, which uses an array of sensors connected to a central processing unit with firmware for continuously monitoring physiological signals. The data collected can be correlated to produce an overall picture of the wearer's health. In this paper, we discuss the wearable physiological monitoring system called 'Smart Vest'. The Smart Vest consists of a comfortable to wear vest with sensors integrated for monitoring physiological parameters, wearable data acquisition and processing hardware and remote monitoring station. The wearable data acquisition system is designed using microcontroller and interfaced with wireless communication and global positioning system (GPS) modules. The physiological signals monitored are electrocardiogram (ECG), photoplethysmogram (PPG), body temperature, blood pressure, galvanic skin response (GSR) and heart rate. The acquired physiological signals are sampled at 250samples/s, digitized at 12-bit resolution and transmitted wireless to a remote physiological monitoring station along with the geo-location of the wearer. The paper describes a prototype Smart Vest system used for remote monitoring of physiological parameters and the clinical validation of the data are also presented.

  11. Monitoring activities of daily living based on wearable wireless body sensor network.

    PubMed

    Kańtoch, E; Augustyniak, P; Markiewicz, M; Prusak, D

    2014-01-01

    With recent advances in microprocessor chip technology, wireless communication, and biomedical engineering it is possible to develop miniaturized ubiquitous health monitoring devices that are capable of recording physiological and movement signals during daily life activities. The aim of the research is to implement and test the prototype of health monitoring system. The system consists of the body central unit with Bluetooth module and wearable sensors: the custom-designed ECG sensor, the temperature sensor, the skin humidity sensor and accelerometers placed on the human body or integrated with clothes and a network gateway to forward data to a remote medical server. The system includes custom-designed transmission protocol and remote web-based graphical user interface for remote real time data analysis. Experimental results for a group of humans who performed various activities (eg. working, running, etc.) showed maximum 5% absolute error compared to certified medical devices. The results are promising and indicate that developed wireless wearable monitoring system faces challenges of multi-sensor human health monitoring during performing daily activities and opens new opportunities in developing novel healthcare services.

  12. An Individualized, Perception-Based Protocol to Investigate Human Physiological Responses to Cooling

    PubMed Central

    Coolbaugh, Crystal L.; Bush, Emily C.; Galenti, Elizabeth S.; Welch, E. Brian; Towse, Theodore F.

    2018-01-01

    Cold exposure, a known stimulant of the thermogenic effects of brown adipose tissue (BAT), is the most widely used method to study BAT physiology in adult humans. Recently, individualized cooling has been recommended to standardize the physiological cold stress applied across participants, but critical experimental details remain unclear. The purpose of this work was to develop a detailed methodology for an individualized, perception-based protocol to investigate human physiological responses to cooling. Participants were wrapped in two water-circulating blankets and fitted with skin temperature probes to estimate BAT activity and peripheral vasoconstriction. We created a thermoesthesia graphical user interface (tGUI) to continuously record the subject's perception of cooling and shivering status during the cooling protocol. The protocol began with a 15 min thermoneutral phase followed by a series of 10 min cooling phases and concluded when sustained shivering (>1 min duration) occurred. Researchers used perception of cooling feedback (tGUI ratings) to manually adjust and personalize the water temperature at each cooling phase. Blanket water temperatures were recorded continuously during the protocol. Twelve volunteers (ages: 26.2 ± 1.4 years; 25% female) completed a feasibility study to evaluate the proposed protocol. Water temperature, perception of cooling, and shivering varied considerably across participants in response to cooling. Mean clavicle skin temperature, a surrogate measure of BAT activity, decreased (−0.99°C, 95% CI: −1.7 to −0.25°C, P = 0.16) after the cooling protocol, but an increase in supraclavicular skin temperature was observed in 4 participants. A strong positive correlation was also found between thermoesthesia and peripheral vasoconstriction (ρ = 0.84, P < 0.001). The proposed individualized, perception-based protocol therefore has potential to investigate the physiological responses to cold stress applied across populations with varying age, sex, body composition, and cold sensitivity characteristics. PMID:29593558

  13. A Server-Based Mobile Coaching System

    PubMed Central

    Baca, Arnold; Kornfeind, Philipp; Preuschl, Emanuel; Bichler, Sebastian; Tampier, Martin; Novatchkov, Hristo

    2010-01-01

    A prototype system for monitoring, transmitting and processing performance data in sports for the purpose of providing feedback has been developed. During training, athletes are equipped with a mobile device and wireless sensors using the ANT protocol in order to acquire biomechanical, physiological and other sports specific parameters. The measured data is buffered locally and forwarded via the Internet to a server. The server provides experts (coaches, biomechanists, sports medicine specialists etc.) with remote data access, analysis and (partly automated) feedback routines. In this way, experts are able to analyze the athlete’s performance and return individual feedback messages from remote locations. PMID:22163490

  14. Phytoplankton IF-FISH: Species-specific labeling of cellular proteins by immunofluorescence (IF) with simultaneous species identification by fluorescence immunohybridization (FISH).

    PubMed

    Meek, Megan E; Van Dolah, Frances M

    2016-05-01

    Phytoplankton rarely occur as unialgal populations. Therefore, to study species-specific protein expression, indicative of physiological status in natural populations, methods are needed that will both assay for a protein of interest and identify the species expressing it. Here we describe a protocol for IF-FISH, a dual labeling procedure using immunofluorescence (IF) labeling of a protein of interest followed by fluorescence in situ hybridization (FISH) to identify the species expressing that protein. The protocol was developed to monitor expression of the cell cycle marker proliferating cell nuclear antigen (PCNA) in the red tide dinoflagellate, Karenia brevis, using a large subunit (LSU) rRNA probe to identify K. brevis in a mixed population of morphologically similar Karenia species. We present this protocol as proof of concept that IF-FISH can be successfully applied to phytoplankton cells. This method is widely applicable for the analysis of single-cell protein expression of any protein of interest within phytoplankton communities. Copyright © 2016 Elsevier B.V. All rights reserved.

  15. Comparison of Physiological and Perceptual Responses Between Continuous and Intermittent Cycling

    PubMed Central

    Brasil, Roxana M.; Barreto, Ana C.; Nogueira, Leandro; Santos, Edil; Novaes, Jefferson S.; Reis, Victor M.

    2011-01-01

    The present study tested the hypothesis that the exercise protocol (continuous vs. intermittent) would affect the physiological response and the perception of effort during aquatic cycling. Each protocol was divided on four stages. Heart rate, arterial blood pressure, blood lactate concentration, central and peripheral rate of perceived exertion were collected in both protocols in aquatic cycling in 10 women (values are mean ± SD): age=32.8 ± 4.8 years; height=1.62 ± 0.05 cm; body mass=61.60 ± 5.19 kg; estimated body fat=27.13 ± 4.92%. Protocols were compared through two way ANOVA with Scheffé’s post-hoc test and the test of Mann- Whitney for rate of perceived exertion with α=0.05. No systematic and consistent differences in heart rate, arterial blood pressure, double product and blood lactate concentration were found between protocols. On the other hand, central rate of perceived exertion was significantly higher at stage four during continuous protocol compared with intermittent protocol (p=0.01), while the peripheral rate of perceived exertion presented higher values at stages three (p=0.02) and four (p=0.00) in the continuous protocol when compared to the results found in intermittent protocol. These findings suggest that although the aquatic cycling induces similar physiologic demands in both protocols, the rate of perceived exertion may vary according to the continuous vs. intermittent nature of the exercise. PMID:23487483

  16. Physiological responses to simulated firefighter exercise protocols in varying environments.

    PubMed

    Horn, Gavin P; Kesler, Richard M; Motl, Robert W; Hsiao-Wecksler, Elizabeth T; Klaren, Rachel E; Ensari, Ipek; Petrucci, Matthew N; Fernhall, Bo; Rosengren, Karl S

    2015-01-01

    For decades, research to quantify the effects of firefighting activities and personal protective equipment on physiology and biomechanics has been conducted in a variety of testing environments. It is unknown if these different environments provide similar information and comparable responses. A novel Firefighting Activities Station, which simulates four common fireground tasks, is presented for use with an environmental chamber in a controlled laboratory setting. Nineteen firefighters completed three different exercise protocols following common research practices. Simulated firefighting activities conducted in an environmental chamber or live-fire structures elicited similar physiological responses (max heart rate: 190.1 vs 188.0 bpm, core temperature response: 0.047°C/min vs 0.043°C/min) and accelerometry counts. However, the response to a treadmill protocol commonly used in laboratory settings resulted in significantly lower heart rate (178.4 vs 188.0 bpm), core temperature response (0.037°C/min vs 0.043°C/min) and physical activity counts compared with firefighting activities in the burn building. Practitioner Summary: We introduce a new approach for simulating realistic firefighting activities in a controlled laboratory environment for ergonomics assessment of fire service equipment and personnel. Physiological responses to this proposed protocol more closely replicate those from live-fire activities than a traditional treadmill protocol and are simple to replicate and standardise.

  17. NASA Space Technology Can Improve Soldier Health, Performance and Safety

    NASA Technical Reports Server (NTRS)

    Cowings, Patricia S.; Toscano, William B.

    2000-01-01

    One of the primary goals of NASA Life Sciences research is '... to enable a permanent human presence in space.' To meet this goal, NASA is creating alternative protocols designed to evaluate and test countermeasures that will account for and correct the environmental effects of space flight on crewmembers health, safety, and operational performance. NASA investigators have previously evaluated the effects of long-duration space flight on physiology and performance of cosmonauts aboard the MIR space station. They also initiated tests of a countermeasure, Autogenic-Feedback Training Exercise (AFTE) designed to prevent and/or correct adverse effects, i.e., facilitate adaptation to space and re-adaptation to Earth. AFTE is a six-hour physiological training program that has proven to be a highly efficient and effective method for enabling people to monitor and voluntarily control a range of their own physiological responses, thereby minimizing adverse reactions to environmental stress. However, because of limited opportunities to test this technology with space flight crews, it is essential to find operational or 'real world' environments in which to validate the efficacy of this approach.

  18. Dynamic whole-body PET parametric imaging: I. Concept, acquisition protocol optimization and clinical application.

    PubMed

    Karakatsanis, Nicolas A; Lodge, Martin A; Tahari, Abdel K; Zhou, Y; Wahl, Richard L; Rahmim, Arman

    2013-10-21

    Static whole-body PET/CT, employing the standardized uptake value (SUV), is considered the standard clinical approach to diagnosis and treatment response monitoring for a wide range of oncologic malignancies. Alternative PET protocols involving dynamic acquisition of temporal images have been implemented in the research setting, allowing quantification of tracer dynamics, an important capability for tumor characterization and treatment response monitoring. Nonetheless, dynamic protocols have been confined to single-bed-coverage limiting the axial field-of-view to ~15-20 cm, and have not been translated to the routine clinical context of whole-body PET imaging for the inspection of disseminated disease. Here, we pursue a transition to dynamic whole-body PET parametric imaging, by presenting, within a unified framework, clinically feasible multi-bed dynamic PET acquisition protocols and parametric imaging methods. We investigate solutions to address the challenges of: (i) long acquisitions, (ii) small number of dynamic frames per bed, and (iii) non-invasive quantification of kinetics in the plasma. In the present study, a novel dynamic (4D) whole-body PET acquisition protocol of ~45 min total length is presented, composed of (i) an initial 6 min dynamic PET scan (24 frames) over the heart, followed by (ii) a sequence of multi-pass multi-bed PET scans (six passes × seven bed positions, each scanned for 45 s). Standard Patlak linear graphical analysis modeling was employed, coupled with image-derived plasma input function measurements. Ordinary least squares Patlak estimation was used as the baseline regression method to quantify the physiological parameters of tracer uptake rate Ki and total blood distribution volume V on an individual voxel basis. Extensive Monte Carlo simulation studies, using a wide set of published kinetic FDG parameters and GATE and XCAT platforms, were conducted to optimize the acquisition protocol from a range of ten different clinically acceptable sampling schedules examined. The framework was also applied to six FDG PET patient studies, demonstrating clinical feasibility. Both simulated and clinical results indicated enhanced contrast-to-noise ratios (CNRs) for Ki images in tumor regions with notable background FDG concentration, such as the liver, where SUV performed relatively poorly. Overall, the proposed framework enables enhanced quantification of physiological parameters across the whole body. In addition, the total acquisition length can be reduced from 45 to ~35 min and still achieve improved or equivalent CNR compared to SUV, provided the true Ki contrast is sufficiently high. In the follow-up companion paper, a set of advanced linear regression schemes is presented to particularly address the presence of noise, and attempt to achieve a better trade-off between the mean-squared error and the CNR metrics, resulting in enhanced task-based imaging.

  19. Dynamic whole body PET parametric imaging: I. Concept, acquisition protocol optimization and clinical application

    PubMed Central

    Karakatsanis, Nicolas A.; Lodge, Martin A.; Tahari, Abdel K.; Zhou, Y.; Wahl, Richard L.; Rahmim, Arman

    2013-01-01

    Static whole body PET/CT, employing the standardized uptake value (SUV), is considered the standard clinical approach to diagnosis and treatment response monitoring for a wide range of oncologic malignancies. Alternative PET protocols involving dynamic acquisition of temporal images have been implemented in the research setting, allowing quantification of tracer dynamics, an important capability for tumor characterization and treatment response monitoring. Nonetheless, dynamic protocols have been confined to single bed-coverage limiting the axial field-of-view to ~15–20 cm, and have not been translated to the routine clinical context of whole-body PET imaging for the inspection of disseminated disease. Here, we pursue a transition to dynamic whole body PET parametric imaging, by presenting, within a unified framework, clinically feasible multi-bed dynamic PET acquisition protocols and parametric imaging methods. We investigate solutions to address the challenges of: (i) long acquisitions, (ii) small number of dynamic frames per bed, and (iii) non-invasive quantification of kinetics in the plasma. In the present study, a novel dynamic (4D) whole body PET acquisition protocol of ~45min total length is presented, composed of (i) an initial 6-min dynamic PET scan (24 frames) over the heart, followed by (ii) a sequence of multi-pass multi-bed PET scans (6 passes x 7 bed positions, each scanned for 45sec). Standard Patlak linear graphical analysis modeling was employed, coupled with image-derived plasma input function measurements. Ordinary least squares (OLS) Patlak estimation was used as the baseline regression method to quantify the physiological parameters of tracer uptake rate Ki and total blood distribution volume V on an individual voxel basis. Extensive Monte Carlo simulation studies, using a wide set of published kinetic FDG parameters and GATE and XCAT platforms, were conducted to optimize the acquisition protocol from a range of 10 different clinically acceptable sampling schedules examined. The framework was also applied to six FDG PET patient studies, demonstrating clinical feasibility. Both simulated and clinical results indicated enhanced contrast-to-noise ratios (CNRs) for Ki images in tumor regions with notable background FDG concentration, such as the liver, where SUV performed relatively poorly. Overall, the proposed framework enables enhanced quantification of physiological parameters across the whole-body. In addition, the total acquisition length can be reduced from 45min to ~35min and still achieve improved or equivalent CNR compared to SUV, provided the true Ki contrast is sufficiently high. In the follow-up companion paper, a set of advanced linear regression schemes is presented to particularly address the presence of noise, and attempt to achieve a better trade-off between the mean-squared error (MSE) and the CNR metrics, resulting in enhanced task-based imaging. PMID:24080962

  20. Dynamic whole-body PET parametric imaging: I. Concept, acquisition protocol optimization and clinical application

    NASA Astrophysics Data System (ADS)

    Karakatsanis, Nicolas A.; Lodge, Martin A.; Tahari, Abdel K.; Zhou, Y.; Wahl, Richard L.; Rahmim, Arman

    2013-10-01

    Static whole-body PET/CT, employing the standardized uptake value (SUV), is considered the standard clinical approach to diagnosis and treatment response monitoring for a wide range of oncologic malignancies. Alternative PET protocols involving dynamic acquisition of temporal images have been implemented in the research setting, allowing quantification of tracer dynamics, an important capability for tumor characterization and treatment response monitoring. Nonetheless, dynamic protocols have been confined to single-bed-coverage limiting the axial field-of-view to ˜15-20 cm, and have not been translated to the routine clinical context of whole-body PET imaging for the inspection of disseminated disease. Here, we pursue a transition to dynamic whole-body PET parametric imaging, by presenting, within a unified framework, clinically feasible multi-bed dynamic PET acquisition protocols and parametric imaging methods. We investigate solutions to address the challenges of: (i) long acquisitions, (ii) small number of dynamic frames per bed, and (iii) non-invasive quantification of kinetics in the plasma. In the present study, a novel dynamic (4D) whole-body PET acquisition protocol of ˜45 min total length is presented, composed of (i) an initial 6 min dynamic PET scan (24 frames) over the heart, followed by (ii) a sequence of multi-pass multi-bed PET scans (six passes × seven bed positions, each scanned for 45 s). Standard Patlak linear graphical analysis modeling was employed, coupled with image-derived plasma input function measurements. Ordinary least squares Patlak estimation was used as the baseline regression method to quantify the physiological parameters of tracer uptake rate Ki and total blood distribution volume V on an individual voxel basis. Extensive Monte Carlo simulation studies, using a wide set of published kinetic FDG parameters and GATE and XCAT platforms, were conducted to optimize the acquisition protocol from a range of ten different clinically acceptable sampling schedules examined. The framework was also applied to six FDG PET patient studies, demonstrating clinical feasibility. Both simulated and clinical results indicated enhanced contrast-to-noise ratios (CNRs) for Ki images in tumor regions with notable background FDG concentration, such as the liver, where SUV performed relatively poorly. Overall, the proposed framework enables enhanced quantification of physiological parameters across the whole body. In addition, the total acquisition length can be reduced from 45 to ˜35 min and still achieve improved or equivalent CNR compared to SUV, provided the true Ki contrast is sufficiently high. In the follow-up companion paper, a set of advanced linear regression schemes is presented to particularly address the presence of noise, and attempt to achieve a better trade-off between the mean-squared error and the CNR metrics, resulting in enhanced task-based imaging.

  1. A comparison of single and multiple stressor protocols to assess acute stress in a coastal shark species, Rhizoprionodon terraenovae.

    PubMed

    Hoffmayer, Eric R; Hendon, Jill M; Parsons, Glenn R; Driggers, William B; Campbell, Matthew D

    2015-10-01

    Elasmobranch stress responses are traditionally measured in the field by either singly or serially sampling an animal after a physiologically stressful event. Although capture and handling techniques are effective at inducing a stress response, differences in protocols could affect the degree of stress experienced by an individual, making meaningful comparisons between the protocols difficult, if not impossible. This study acutely stressed Atlantic sharpnose sharks, Rhizoprionodon terraenovae, by standardized capture (rod and reel) and handling methods and implemented either a single or serial blood sampling protocol to monitor four indicators of the secondary stress response. Single-sampled sharks were hooked and allowed to swim around the boat until retrieved for a blood sample at either 0, 15, 30, 45, or 60 min post-hooking. Serially sampled sharks were retrieved, phlebotomized, released while still hooked, and subsequently resampled at 15, 30, 45, and 60 min intervals post-hooking. Blood was analyzed for hematocrit, and plasma glucose, lactate, and osmolality levels. Although both single and serial sampling protocols resulted in an increase in glucose, no significant difference in glucose level was found between protocols. Serially sampled sharks exhibited cumulatively heightened levels for lactate and osmolality at all time intervals when compared to single-sampled animals at the same time. Maximal concentration differences of 217.5, 9.8, and 41.6 % were reported for lactate, osmolality, and glucose levels, respectively. Hematocrit increased significantly over time for the single sampling protocol but did not change significantly during the serial sampling protocol. The differences in resultant blood chemistry levels between implemented stress protocols and durations are significant and need to be considered when assessing stress in elasmobranchs.

  2. Oral dosing of chemical indicators for in vivo monitoring of Ca2+ dynamics in insect muscle.

    PubMed

    Ferdinandus; Arai, Satoshi; Ishiwata, Shin'ichi; Suzuki, Madoka; Sato, Hirotaka

    2015-01-01

    This paper proposes a remarkably facile staining protocol to visually investigate dynamic physiological events in insect tissues. We attempted to monitor Ca2+ dynamics during contraction of electrically stimulated living muscle. Advances in circuit miniaturization and insect neuromuscular physiology have enabled the hybridization of living insects and man-made electronic components, such as microcomputers, the result of which has been often referred as a Living Machine, Biohybrid, or Cyborg Insect. In order for Cyborg Insects to be of practical use, electrical stimulation parameters need to be optimized to induce desired muscle response (motor action) and minimize the damage in the muscle due to the electrical stimuli. Staining tissues and organs as well as measuring the dynamics of chemicals of interest in muscle should be conducted to quantitatively and systematically evaluate the effect of various stimulation parameters on the muscle response. However, existing staining processes require invasive surgery and/or arduous procedures using genetically encoded sensors. In this study, we developed a non-invasive and remarkably facile method for staining, in which chemical indicators can be orally administered (oral dosing). A chemical Ca2+ indicator was orally introduced into an insect of interest via food containing the chemical indicator and the indicator diffused from the insect digestion system to the target muscle tissue. We found that there was a positive relationship between the fluorescence intensity of the indicator and the frequency of electrical stimulation which indicates the orally dosed indicator successfully monitored Ca2+ dynamics in the muscle tissue. This oral dosing method has a potential to globally stain tissues including neurons, and investigating various physiological events in insects.

  3. Oral Dosing of Chemical Indicators for In Vivo Monitoring of Ca2+ Dynamics in Insect Muscle

    PubMed Central

    Ferdinandus; Arai, Satoshi; Ishiwata, Shin’ichi; Suzuki, Madoka; Sato, Hirotaka

    2015-01-01

    This paper proposes a remarkably facile staining protocol to visually investigate dynamic physiological events in insect tissues. We attempted to monitor Ca2+ dynamics during contraction of electrically stimulated living muscle. Advances in circuit miniaturization and insect neuromuscular physiology have enabled the hybridization of living insects and man-made electronic components, such as microcomputers, the result of which has been often referred as a Living Machine, Biohybrid, or Cyborg Insect. In order for Cyborg Insects to be of practical use, electrical stimulation parameters need to be optimized to induce desired muscle response (motor action) and minimize the damage in the muscle due to the electrical stimuli. Staining tissues and organs as well as measuring the dynamics of chemicals of interest in muscle should be conducted to quantitatively and systematically evaluate the effect of various stimulation parameters on the muscle response. However, existing staining processes require invasive surgery and/or arduous procedures using genetically encoded sensors. In this study, we developed a non-invasive and remarkably facile method for staining, in which chemical indicators can be orally administered (oral dosing). A chemical Ca2+ indicator was orally introduced into an insect of interest via food containing the chemical indicator and the indicator diffused from the insect digestion system to the target muscle tissue. We found that there was a positive relationship between the fluorescence intensity of the indicator and the frequency of electrical stimulation which indicates the orally dosed indicator successfully monitored Ca2+ dynamics in the muscle tissue. This oral dosing method has a potential to globally stain tissues including neurons, and investigating various physiological events in insects. PMID:25590329

  4. Enhancement of absorption and resistance of motion utilizing a multi-channel opto-electronic sensor to effectively monitor physiological signs during sport exercise

    NASA Astrophysics Data System (ADS)

    Alzahrani, Abdullah; Hu, Sijung; Azorin-Peris, Vicente; Barrett, Laura; Esliger, Dale; Hayes, Matthew; Akbare, Shafique; Achart, Jérôme; Kuoch, Sylvain

    2015-03-01

    This study presents an effective engineering approach for human vital signs monitoring as increasingly demanded by personal healthcare. The aim of this work is to study how to capture critical physiological parameters efficiently through a well-constructed electronic system and a robust multi-channel opto-electronic patch sensor (OEPS), together with a wireless communication. A unique design comprising multi-wavelength illumination sources and a rapid response photo sensor with a 3-axis accelerometer enables to recover pulsatile features, compensate motion and increase signal-to-noise ratio. An approved protocol with designated tests was implemented at Loughborough University a UK leader in sport and exercise assessment. The results of sport physiological effects were extracted from the datasets of physical movements, i.e. sitting, standing, waking, running and cycling. t-test, Bland-Altman and correlation analysis were applied to evaluate the performance of the OEPS system against Acti-Graph and Mio-Alpha.There was no difference in heart rate measured using OEPS and both Acti-Graph and Mio-Alpha (both p<0.05). Strong correlations were observed between HR measured from the OEPS and both the Acti-graph and Mio-Alpha (r = 0.96, p<0.001). Bland-Altman analysis for the Acti-Graph and OEPS found the bias 0.85 bpm, the standard deviation 9.20 bpm, and the limits of agreement (LOA) -17.18 bpm to +18.88 bpm for lower and upper limits of agreement respectively, for the Mio-Alpha and OEPS the bias is 1.63 bpm, standard deviation SD8.62 bpm, lower and upper limits of agreement, - 15.27 bpm and +18.58 bpm respectively. The OEPS demonstrates a real time, robust and remote monitoring of cardiovascular function.

  5. 8A.03: CONTINUOUS MONITORING OF HEMODYNAMICS IN THE SHORT ARM HUMAN CENTRIFUGE: A FEASIBILITY STUDY.

    PubMed

    Londono, F; Uytterhaegen, B; Kassel, R; Vanraemdonck, R; Beck, A; Comet, B; Runge, A; Segers, P

    2015-06-01

    The aim was to test the technical feasibility of a set up combining tonometry and ultrasound, designated as Continuous Physiological and Medical Monitoring (CPMM), for cardiovascular assessment on humans and to evaluate the ability to assess physiological changes induced by artificial gravity in the short arm human centrifuge (SAHC, Verhaert, Belgium) for detecting and preventing potential disorders induced by weightlessness. The project was developed under an European Space Agency (ESA) contract (4000101988/10/NL/EM) and with its support, by the company Verhaert in consortium with the Institute for Space Medicine and Physiology (MEDES) and Ghent University. Measurements were performed at MEDES facilities in 4 young (presumably) healthy volunteers (3 males). For two volunteers, the protocol was divided in three periods: acceleration, steady rotation velocity and deceleration, obtaining carotid pulsed wave (PW)-Mode ultrasound sequences. For another volunteer (female), carotid PW-Mode ultrasound images and brachial and radial tonometry signals were acquired at baseline and during steady rotation. For the fourth volunteer, carotid and femoral PW-Mode ultrasound images and brachial, radial and carotid tonometry signals were acquired at baseline and during an initial (velocity1) and a following faster (velocity2) rotation velocity (see figure on the following page). Carotid PW-Mode ultrasound imaging was obtained in all 4 volunteers during different steps of the protocol. Femoral ultrasound imaging presented more difficulties related mainly to the placement of the probe after baseline, even if in one case results were feasible. Tonometry was, generally, a bigger challenge due to the intrinsic sensitivity of the method. Overall, radial artery tonometry provided the best results, while brachial artery results were acceptable only in one occasion. Carotid tonometry was measured only for one subject with suitable results for processing. Tonometry measurements were feasible under a spin velocity limit, while PW-Mode ultrasound images were more robust and stable. Although general conclusions must be supported by a larger sample, suitable signals and locations were identified and a user friendly and mobile set-up was tested successfully and it is available for further research to identified and assess mechanisms and reflexes acting in physiological adaptation to various gravity conditions.(Figure is included in full-text article.).

  6. Strain - The Heart of the Matter

    NASA Technical Reports Server (NTRS)

    Gapinski, Wendy R.

    2013-01-01

    Objective: Identify how much exercise is needed to maintain pre-bedrest / pre-spaceflight strength, minimize any flight complications and reduce time required to reacclimate to Earth's gravity. Subjects volunteered to participate in a 70 day 6deg head down tilt (HDT) study at UTMB hospital in Galveston. HDT are used to study microgravity for several reasons: 1. Allows subjects to experience atrophy of lower extremities from disuse. 2. Allows scientist to study the fluid shifts and the subject's cardiovascular and physiological effects. 3. Allows several studies to be measured and conducted simultaneously in a safe and monitored environment. Throughout those 10 weeks, subjects were either in an exercise or control group. Never before has cardiac strain been monitored at set time points throughout spaceflight or bed rest study. Once we clearly understand this technique, protocols can be formulated for astronauts to use on the ISS as both a diagnostic and monitoring tool. Echoes could have the possibility to predict & monitor heart health, cardiac strength, endurance, and overall rate of muscle degradation. Also, echoes can act as an additional factor in determining exercise prescriptions and effectiveness.

  7. Positive Bioluminescence Imaging of MicroRNA Expression in Small Animal Models Using an Engineered Genetic-Switch Expression System, RILES.

    PubMed

    Baril, Patrick; Pichon, Chantal

    2016-01-01

    MicroRNAs (miRNAs) are a class of small, noncoding RNAs which regulate gene expression by directing their target mRNA for degradation or translational repression. Since their discovery in the early 1990s, miRNAs have emerged as key components in the posttranscriptional regulation of gene networks, shaping many biological processes from development, morphogenesis, differentiation, proliferation and apoptosis. Although understanding of the molecular basis of miRNA biology is improving, methods to monitor the dynamic and the spatiotemporal aspects of miRNA expression under physiopathological conditions are required. However, monitoring of miRNAs is difficult due to their small size, low abundance, high degree of sequence similarity, and their dynamic expression pattern which is subjected to tight transcriptional and post-transcriptional controls. Recently, we developed a miRNA monitoring system called RILES, standing for RNAi-inducible expression system, which relies on an engineered regulatable expression system, to switch on the expression of the luciferase gene when the targeted miRNA is expressed in cells. We demonstrated that RILES is a specific, sensitive, and robust method to determine the fine-tuning of miRNA expression during the development of an experimental pathological process in mice. Because RILES offers the possibility for longitudinal studies on individual subjects, sharper insights into miRNA regulation can be generated, with applications in physiology, pathophysiology and development of RNAi-based therapies. This chapter describes methods and protocols to monitor the expression of myomiR-206, -1, and -133 in the tibialis anterior muscle of mice. These protocols can be used and adapted to monitor the expression of other miRNAs in other biological processes.

  8. CARDIORESPIRATORY EFFECTS OF DEXMEDETOMIDINE-BUTORPHANOL-MIDAZOLAM (DBM): A FULLY REVERSIBLE ANESTHETIC PROTOCOL IN CAPTIVE AND SEMI-FREE-RANGING CHEETAHS (ACINONYX JUBATUS).

    PubMed

    Woc Colburn, A Margarita; Murray, Suzan; Hayek, Lee-Ann C; Marker, Laurie; Sanchez, Carlos R

    2017-03-01

    Multiple anesthesia protocols have been used in the cheetah ( Acinonyx jubatus ). Twenty healthy, captive cheetahs were immobilized with dexmedetomidine (15.8 ± 1.9 μg/kg), butorphanol (0.22 ± 0.03 mg/kg), and midazolam (0.18 ± 0.03 mg/kg) by intramuscular injection. Induction, recumbency, and recovery times were recorded, and physiologic parameters were monitored. Anesthesia was antagonized with atipamezole (0.125 ± 0.02 mg/kg) and naltrexone (0.1 ± 0.014 mg/kg) intramuscularly. All cheetahs were safely anesthetized with this protocol. Cheetahs were laterally recumbent by 8 ± 3.5 min. Cardiorespiratory values were stable throughout the length of anesthesia. Moderate hypertension, with systolic blood pressure ranging from 178 ± 19.8 mm Hg, was initially observed but decreased over time. There was a statistical decreasing trend in temperature; SpO2; and systolic, mean, and diastolic blood pressure, but not in heart rate and end-tidal CO 2 . Recoveries were rapid, with cheetahs standing by 11.3 ± 5.7 min postreversal administration. This is the first report of a dexmedetomidine-butorphanol-midazolam anesthetic combination in cheetahs. Overall, this anesthetic protocol proved to be safe and effective.

  9. Single-cell time-lapse imaging of intracellular O2 in response to metabolic inhibition and mitochondrial cytochrome-c release.

    PubMed

    Düssmann, Heiko; Perez-Alvarez, Sergio; Anilkumar, Ujval; Papkovsky, Dmitri B; Prehn, Jochen Hm

    2017-06-01

    The detection of intracellular molecular oxygen (O 2 ) levels is important for understanding cell physiology, cell death, and drug effects, and has recently been improved with the development of oxygen-sensitive probes that are compatible with live cell time-lapse microscopy. We here provide a protocol for the use of the nanoparticle probe MitoImage-MM2 to monitor intracellular oxygen levels by confocal microscopy under baseline conditions, in response to mitochondrial toxins, and following mitochondrial cytochrome-c release. We demonstrate that the MitoImage-MM2 probe, which embeds Pt(II)-5,10,15,20-tetrakis-(2,3,4,5,6-pentafluorophenyl)-porphyrin as oxygen sensor and poly(9,9-dioctylfluorene) as an O 2 -independent component, enables quantitative, ratiometric time-lapse imaging of intracellular O 2 . Multiplexing with tetra-methyl-rhodamine-methyl ester in HeLa cervical cancer cells showed significant increases in intracellular O 2 accompanied by strong mitochondrial depolarization when respiratory chain complexes III or IV were inhibited by Antimycin A or sodium azide, respectively, and when cells were maintained at 'physiological' tissue O 2 levels (5% O 2 ). Multiplexing also allowed us to monitor intracellular O 2 during the apoptotic signaling process of mitochondrial outer membrane permeabilization in HeLa expressing cytochrome-c-eGFP, and demonstrated that mitochondria post cytochrome-c release are able to retain their capacity to respire at physiological O 2 despite a decrease in mitochondrial membrane potential.

  10. Comparison of Two Methods for Noninvasive Determination of Stroke Volume During Orthostatic Challenge

    NASA Technical Reports Server (NTRS)

    Doerr, Donald F.; Ratliff, Duane A.; Sithole, Joseph; Convertino, Victor A.

    2005-01-01

    Background: The real time, beat-by-beat, non-invasive determination of stroke volume (SV) is an important parameter in many aerospace related physiologic protocols. In this study, we compared simultaneous estimates of SV calculated from peripheral pulse waveforms with a more conventional non-invasive technique. Methods: Using a prospective, randomized blinded protocol, ten males and nine females completed 12-mm tilt table protocols. The relative change (%(Delta)) in beat-to-beat SV was estimated non-invasively from changes in pulse waveforms measured by application of infrared finger photoplethysmography (IFP) with a Portapres(Registered TradeMark) blood pressure monitoring device and by thoracic impedance cardiography (TIC). The %(Delta) SV values were calculated from continuous SV measurements in the supine posture and over the first 10 s (T1), second 10 s (T2), and 3.5 minutes (T3) of 80deg head-up tilt (HUT). Results: The average %(Delta) SV measured by IFP at T1 (-11.7 +/- 3.7 %) was statistically less (P <0.02) than the average %(Delta) SV measured by TIC at T1 (-21.7 +/- 3.1 %), while the average %(Delta) SV measured by 1FF at T2 (-16.2 +/- 3.9 %) and T3 (-19.1 +/- 3.8 %) were not statistically distinguishable (P > or = 0.322) than the average %(Delta) SV measured by TIC at T2 (-21.8 +/- 2.5 %), and T3 (-22.6 +/- 2.9 %). Correlation coefficients (r(sup 2)) between IFP and TIC were 0.117 (T1), 0.387 (T2), and 0.7 18 (T3). Conclusion: IFP provides beat-to-beat (real time) assessment of %(Delta) SV after 20 sec of transition to an orthostatic challenge that is comparable to the commonly accepted TIC. Our data support the notion that IFP technology which has flown during space missions can be used to accurately assess physiological status and countermeasure effectiveness for orth static problems that may arise in astronauts after space flight. While the peripherally measured IFP response is slightly delayed, the ease of implementing this monitor in the field is advantageous.

  11. Physiologic monitoring. A guide to networking your monitoring systems.

    PubMed

    2011-10-01

    There are many factors to consider when choosing a physiologic monitoring system. not only should these systems perform well clinically, but they should also be able to exchange data with other information systems. We discuss some of the ins and outs of physiologic monitoring system networking and highlight eight product lines from seven suppliers.

  12. An Integrated Approach for the Monitoring of Brain and Autonomic Response of Children with Autism Spectrum Disorders during Treatment by Wearable Technologies

    PubMed Central

    Billeci, Lucia; Tonacci, Alessandro; Tartarisco, Gennaro; Narzisi, Antonio; Di Palma, Simone; Corda, Daniele; Baldus, Giovanni; Cruciani, Federico; Anzalone, Salvatore M.; Calderoni, Sara; Pioggia, Giovanni; Muratori, Filippo

    2016-01-01

    Autism Spectrum Disorders (ASD) are associated with physiological abnormalities, which are likely to contribute to the core symptoms of the condition. Wearable technologies can provide data in a semi-naturalistic setting, overcoming the limitations given by the constrained situations in which physiological signals are usually acquired. In this study an integrated system based on wearable technologies for the acquisition and analysis of neurophysiological and autonomic parameters during treatment is proposed and an application on five children with ASD is presented. Signals were acquired during a therapeutic session based on an imitation protocol in ASD children. Data were analyzed with the aim of extracting quantitative EEG (QEEG) features from EEG signals as well as heart rate and heart rate variability (HRV) from ECG. The system allowed evidencing changes in neurophysiological and autonomic response from the state of disengagement to the state of engagement of the children, evidencing a cognitive involvement in the children in the tasks proposed. The high grade of acceptability of the monitoring platform is promising for further development and implementation of the tool. In particular if the results of this feasibility study would be confirmed in a larger sample of subjects, the system proposed could be adopted in more naturalistic paradigms that allow real world stimuli to be incorporated into EEG/psychophysiological studies for the monitoring of the effect of the treatment and for the implementation of more individualized therapeutic programs. PMID:27445652

  13. Automation of a Nile red staining assay enables high throughput quantification of microalgal lipid production.

    PubMed

    Morschett, Holger; Wiechert, Wolfgang; Oldiges, Marco

    2016-02-09

    Within the context of microalgal lipid production for biofuels and bulk chemical applications, specialized higher throughput devices for small scale parallelized cultivation are expected to boost the time efficiency of phototrophic bioprocess development. However, the increasing number of possible experiments is directly coupled to the demand for lipid quantification protocols that enable reliably measuring large sets of samples within short time and that can deal with the reduced sample volume typically generated at screening scale. To meet these demands, a dye based assay was established using a liquid handling robot to provide reproducible high throughput quantification of lipids with minimized hands-on-time. Lipid production was monitored using the fluorescent dye Nile red with dimethyl sulfoxide as solvent facilitating dye permeation. The staining kinetics of cells at different concentrations and physiological states were investigated to successfully down-scale the assay to 96 well microtiter plates. Gravimetric calibration against a well-established extractive protocol enabled absolute quantification of intracellular lipids improving precision from ±8 to ±2 % on average. Implementation into an automated liquid handling platform allows for measuring up to 48 samples within 6.5 h, reducing hands-on-time to a third compared to manual operation. Moreover, it was shown that automation enhances accuracy and precision compared to manual preparation. It was revealed that established protocols relying on optical density or cell number for biomass adjustion prior to staining may suffer from errors due to significant changes of the cells' optical and physiological properties during cultivation. Alternatively, the biovolume was used as a measure for biomass concentration so that errors from morphological changes can be excluded. The newly established assay proved to be applicable for absolute quantification of algal lipids avoiding limitations of currently established protocols, namely biomass adjustment and limited throughput. Automation was shown to improve data reliability, as well as experimental throughput simultaneously minimizing the needed hands-on-time to a third. Thereby, the presented protocol meets the demands for the analysis of samples generated by the upcoming generation of devices for higher throughput phototrophic cultivation and thereby contributes to boosting the time efficiency for setting up algae lipid production processes.

  14. Combining accuracy assessment of land-cover maps with environmental monitoring programs

    USGS Publications Warehouse

    Stehman, S.V.; Czaplewski, R.L.; Nusser, S.M.; Yang, L.; Zhu, Z.

    2000-01-01

    A scientifically valid accuracy assessment of a large-area, land-cover map is expensive. Environmental monitoring programs offer a potential source of data to partially defray the cost of accuracy assessment while still maintaining the statistical validity. In this article, three general strategies for combining accuracy assessment and environmental monitoring protocols are described. These strategies range from a fully integrated accuracy assessment and environmental monitoring protocol, to one in which the protocols operate nearly independently. For all three strategies, features critical to using monitoring data for accuracy assessment include compatibility of the land-cover classification schemes, precisely co-registered sample data, and spatial and temporal compatibility of the map and reference data. Two monitoring programs, the National Resources Inventory (NRI) and the Forest Inventory and Monitoring (FIM), are used to illustrate important features for implementing a combined protocol.

  15. In Situ Target Engagement Studies in Adherent Cells.

    PubMed

    Axelsson, Hanna; Almqvist, Helena; Otrocka, Magdalena; Vallin, Michaela; Lundqvist, Sara; Hansson, Pia; Karlsson, Ulla; Lundbäck, Thomas; Seashore-Ludlow, Brinton

    2018-04-20

    A prerequisite for successful drugs is effective binding of the desired target protein in the complex environment of a living system. Drug-target engagement has typically been difficult to monitor in physiologically relevant models, and with current methods, especially, while maintaining spatial information. One recent technique for quantifying drug-target engagement is the cellular thermal shift assay (CETSA), in which ligand-induced protein stabilization is measured after a heat challenge. Here, we describe a CETSA protocol in live A431 cells for p38α (MAPK14), where remaining soluble protein is detected in situ, using high-content imaging in 384-well, microtiter plates. We validate this assay concept using a number of known p38α inhibitors and further demonstrate the potential of this technology for chemical probe and drug discovery purposes by performing a small pilot screen for novel p38α binders. Importantly, this protocol creates a workflow that is amenable to adherent cells in their native state and yields spatially resolved target engagement information measurable at the single-cell level.

  16. Laboratory testing protocol for the impact of dispersed petrochemicals on seagrass.

    PubMed

    Wilson, K G; Ralph, P J

    2012-11-01

    To improve the effectiveness of oil spill mitigation, we developed a rapid, logistically simple protocol to detect petrochemical stress on seagrass. Sections of leaf blades from Zostera muelleri subsp. capricorni were exposed to the water accommodated fraction (WAF) of non-dispersed and dispersed Tapis crude oil and fuel oil (IFO-380) for 5h. Photosynthetic health was monitored by assessing changes in effective quantum yield of photosystem II (ΔF/F(m)(')) and chlorophyll a pigment concentrations. Loss of total petroleum hydrocarbons (TPH) was measured using an oil-in-water fluorometer, whilst GC-MS analyses quantified the hydrocarbon components within each treatment. Few significant differences were detected in the chlorophyll a pigment analyses; however, ΔF/F(m)(') appeared sensitive to petrochemical exposure. Dispersing both types of oil resulted in a substantial increase in the TPH of the WAF and was generally correlated with a greater physiological impact to the seagrass health, compared with the oil alone. Copyright © 2012 Elsevier Ltd. All rights reserved.

  17. RNA Imaging with Dimeric Broccoli in Live Bacterial and Mammalian Cells

    PubMed Central

    Filonov, Grigory S.

    2016-01-01

    RNA spatial dynamics play a crucial role in cell physiology and thus the ability to monitor RNA localization in live cells can provide insight into important biological problems. This article focuses on imaging RNAs using an “RNA mimic of GFP”. This approach relies on a RNA aptamer, called dimeric Broccoli, which binds to and switches on the fluorescence of DFHBI, a small molecule mimicking the fluorophore in GFP. Dimeric Broccoli is tagged to heterologously expressed RNAs and upon DFHBI binding the fluorescent signal of dimeric Broccoli reports the transcript’s localization in cells. This protocol describes the process of validating the fluorescence of dimeric Broccoli-labeled transcripts in vitro and in cells, flow cytometry analysis to determine overall fluorescence levels in cells, and fluorescence imaging in bacterial and mammalian cells. Overall, the current protocol should be useful for researchers seeking to image high abundance RNAs, such as transcribed off the T7 promoter in bacteria or off Pol III-dependent promoters in mammalian cells. PMID:26995352

  18. Recommended features of protocols for long-term ecological monitoring

    USGS Publications Warehouse

    Oakley, Karen L.; Boudreau, Susan L.; Humphrey, Sioux-Z

    2001-01-01

    In 1991, the National Park Service (NPS) selected seven parks to serve as prototypes for development of a long-term ecological monitoring program. Denali National Park and Preserve was one of the prototype parks selected. The principal focus of this national program was to detect and document resource changes and to understand the forces driving those changes. One of the major tasks of each prototype park was to develop monitoring protocols. In this paper, we discuss some lessons learned and what we believe to be the most important features of protocols.One of the many lessons we have learned is that monitoring protocols vary greatly in content and format. This variation leads to confusion about what information protocols should contain and how they should be formatted. Problems we have observed in existing protocols include (1) not providing enough detail, (2) omitting critical topics (such as data management), and (3) mixing explanation with instructions. Once written, protocols often sit on the shelf to collect dust, allowing methods changes to occur without being adequately considered, tested, or documented. Because a lengthy and costly research effort is often needed to develop protocols, a vision of what the final product should look like is helpful. Based on our involvement with the prototype monitoring program for Denali (Oakley and Boudreau 2000), we recommend key features of protocols, including a scheme for linking protocols to data in the data management system and for tracking protocol revisions. A protocol system is crucial for producing long-term data sets of known quality that meet program objectives.

  19. Subcellular evidences of redox imbalance in well-established populations of an endangered limpet. Reasons for alarm?

    PubMed

    Espinosa, Free; Rivera-Ingraham, Georgina A

    2016-08-15

    Intertidal species are more vulnerable to anthropogenic disturbances than others inhabiting subtidal and offshore habitats. Coastal development frequently results in trace-metal pollution. For endangered species such as Patella ferruginea it can be a high risk that leads local populations to extinction. Three localities were surveyed, one within a natural and unpolluted area and the other two within the harbor of Ceuta (Strait of Gibraltar), on breakwaters outside and inside. The specimens collected inside the harbor reached 3-fold higher Hg content than for those incoming from the natural area. PERMANOVA test indicated that metal composition of the specimens from inside the harbor was different from the rest. In addition, evidence of cell damage was detected in the specimens from the harbor area. This highlights the urgency of undertaking a physiological evaluation of some of the most vulnerable populations, establishing eco-physiological protocols for monitoring and managing populations settled on artificial substrata. Copyright © 2016 Elsevier Ltd. All rights reserved.

  20. Molecular clocks and the human condition: approaching their characterization in human physiology and disease.

    PubMed

    Fitzgerald, G A; Yang, G; Paschos, G K; Liang, X; Skarke, C

    2015-09-01

    Molecular clockworks knit together diverse biological networks and compelling evidence from model systems infers their importance in metabolism, immunological and cardiovascular function. Despite this and the diurnal variation in many aspects of human physiology and the phenotypic expression of disease, our understanding of the role and importance of clock function and dysfunction in humans is modest. There are tantalizing hints of connection across the translational divide and some correlative evidence of gene variation and human disease but most of what we know derives from forced desynchrony protocols in controlled environments. We now have the ability to monitor quantitatively ex vivo or in vivo the genome, metabolome, proteome and microbiome of humans in the wild. Combining this capability, with the power of mobile telephony and the evolution of remote sensing, affords a new opportunity for deep phenotyping, including the characterization of diurnal behaviour and the assessment of the impact of the clock on approved drug function. © 2015 John Wiley & Sons Ltd.

  1. Automated monitoring of medical protocols: a secure and distributed architecture.

    PubMed

    Alsinet, T; Ansótegui, C; Béjar, R; Fernández, C; Manyà, F

    2003-03-01

    The control of the right application of medical protocols is a key issue in hospital environments. For the automated monitoring of medical protocols, we need a domain-independent language for their representation and a fully, or semi, autonomous system that understands the protocols and supervises their application. In this paper we describe a specification language and a multi-agent system architecture for monitoring medical protocols. We model medical services in hospital environments as specialized domain agents and interpret a medical protocol as a negotiation process between agents. A medical service can be involved in multiple medical protocols, and so specialized domain agents are independent of negotiation processes and autonomous system agents perform monitoring tasks. We present the detailed architecture of the system agents and of an important domain agent, the database broker agent, that is responsible of obtaining relevant information about the clinical history of patients. We also describe how we tackle the problems of privacy, integrity and authentication during the process of exchanging information between agents.

  2. Using broadband spatially resolved NIRS to assess muscle oxygenation during altered running protocols

    NASA Astrophysics Data System (ADS)

    Koukourakis, Georg; Vafiadou, Maria; Steimers, André; Geraskin, Dmitri; Neary, Patrick; Kohl-Bareis, Matthias

    2009-07-01

    We used spatially resolved near-infrared spectroscopy (SRS-NIRS) to assess calf and thigh muscle oxygenation during running on a motor-driven treadmill. Two protocols were used: An incremental speed protocol (velocity = 6 - 12 km/h, ▵v = 2 km/h) was performed in 3 minute stages, while a pacing paradigm modulated step frequency alternatively (2.3 Hz [SLow]; 3.3 Hz [SHigh]) during a constant velocity for 2 minutes each. A SRS-NIRS broadband system (600 - 1000 nm) was used to measure total haemoglobin concentration and oxygen saturation (SO2). An accelerometer was placed on the hip joints to measure limb acceleration through the experiment. The data showed that the calf (SO2 58 to 42%) desaturated to a significantly lower level than the thigh (61 to 54%). During the pacing protocol, SO2 was significantly different between the SLow vs. SHigh trials. Additionally, physiological data as measured by spirometry were different between the SLow vs. SHigh pacing trials (VO2 (2563+/- 586 vs. 2503 +/- 605 mL/min). Significant differences in VO2 at the same workload (speed) indicate alterations in mechanical efficiency. These data suggest that SRS broadband NIRS can be used to discern small changes in muscle oxygenation, making this device useful for metabolic exercise studies in addition to spirometry and movement monitoring by accelerometers.

  3. The development of a tele-monitoring system for physiological parameters based on the B/S model.

    PubMed

    Shuicai, Wu; Peijie, Jiang; Chunlan, Yang; Haomin, Li; Yanping, Bai

    2010-01-01

    The development of a new physiological multi-parameter remote monitoring system is based on the B/S model. The system consists of a server monitoring center, Internet network and PC-based multi-parameter monitors. Using the B/S model, the clients can browse web pages via the server monitoring center and download and install ActiveX controls. The physiological multi-parameters are collected, displayed and remotely transmitted. The experimental results show that the system is stable, reliable and operates in real time. The system is suitable for use in physiological multi-parameter remote monitoring for family and community healthcare. Copyright © 2010 Elsevier Ltd. All rights reserved.

  4. EPA Traceability Protocol for Assay and Certification of Gaseous Calibration Standards

    EPA Pesticide Factsheets

    EPA's air monitoring regulations require the use of Protocol Gases to set air pollution monitors. This protocol balances the government's need for accuracy with the producers' need for flexibility, low cost, and minimum external oversight.

  5. Personal health records: mobile biosensors and smartphones for developing countries.

    PubMed

    Simon, Sternly K; Seldon, H Lee

    2012-01-01

    A target of telehealth is to maintain or improve the health of people outside the normal healthcare infrastructure. A modern paradigm in healthcare, and one which fits perfectly with telehealth, is "person self-monitoring", and this fits with the concept of "personal health record" (PHR). One factor in maintaining health is to monitor physiological parameters; this is of course especially important in people with chronic maladies such as diabetes or heart disease. Parameters to be monitored include blood pressure, pulse rate, temperature, weight, blood glucose, oxygen saturation, electrocardiogram (ECG), etc. So one task within telehealth would be to help monitor an individual's physiological parameters outside of healthcare institutions and store the results in a PHR in a way which is available, comprehensible and beneficial to the individual concerned and to healthcare providers. To date many approaches to this problem have been fragmented - emphasizing only part of the problem - or proprietary and not freely verifiable. We describe a framework to approach this task; it emphasizes the implementation of standards for data acquisition, storage and transmission in order to maximize the compatibility among disparate components, e.g. various PHR systems. Data from mobile biosensors is collected on a smartphone using the IEEE 11073 standard where possible; the data can be stored in a PHR on the phone (using standard formats) or can be converted in real-time into more useful information in the PHR, which is based on the International Classification for Primary Care (ICPC2e). The phone PHR data or information can be uploaded to a central online PHR using either the Wi-Fi or GSM transmission protocol together with the Continuity of Care Record message format (CCR, ASTM E2369).

  6. Cognitive Imagery and Physiological Feedback Relaxation Protocols Applied to Clinically Tense Young Adults: A Comparison of State, Trait, and Physiological Effects.

    ERIC Educational Resources Information Center

    Schandler, Steven L.; Dana, Edward R.

    1983-01-01

    Examined changes in tension behaviors and reductions in physiological tension associated with cognitive imagery and electromyographic biofeedback relaxation procedures in 45 college students. Results showed: imagery significantly reduced state anxiety. Self-rest was less effective; biofeedback greatly reduced physiological tension, but not state…

  7. Adherence to Diurnal Cortisol Sampling Among Mother-Child Dyads From Maltreating and Nonmaltreating Families.

    PubMed

    Valentino, Kristin; De Alba, Ashley; Hibel, Leah C; Fondren, Kaitlin; McDonnell, Christina G

    2017-11-01

    There has been increasing interest in evaluating whether interventions for child maltreatment can improve and/or prevent child physiological dysregulation via measurement of diurnal cortisol. The assessment of diurnal cortisol typically involves the home-based collection of saliva multiple times per day, bringing forth important methodological considerations regarding adherence to collection instructions. To date, there has been no data regarding adherence to home collection of diurnal cortisol among maltreating families. The current study provides data on adherence to in-home sampling of salivary cortisol among 166 maltreating and demographically similar nonmaltreating mother-child dyads using electronic monitoring devices (Medication Event Monitoring System caps). Mothers collected saliva samples on themselves and their children 3 times per day (waking, midday, and evening) for 2 consecutive days. Analyses reveal that although maltreating families were more likely to be nonadherent to the collection protocol on their initial attempt, with additional support and resampling, maltreating and nonmaltreating families were comparable on most measures of adherence. Suggestions for best practices, including the use of electronic monitoring devices, for diurnal cortisol collection with maltreating families are provided.

  8. Application of Acceleration Sensors in Physiological Experiments

    NASA Astrophysics Data System (ADS)

    Vavrinský, Erik; Moskal'vá, Daniela; Darříček, Martin; Donoval, Martin; Horínek, František; Popovič, Marían; Miklovič, Peter

    2014-09-01

    This paper illustrates a promising application of an accelerometer sensor in physiological research, we demonstrated use of accelerometers for monitoring the standard proband physical activity (PA) and also in special applications like respiration and mechanical heart activity, the so-called seismocardiography (SCG) monitoring, physiological activation monitoring and mechanomyography (MMG)

  9. Linking Landscape-Scale Disturbances to Stress and Condition of Fish: Implications for Restoration and Conservation.

    PubMed

    Jeffrey, Jennifer D; Hasler, Caleb T; Chapman, Jacqueline M; Cooke, Steven J; Suski, Cory D

    2015-10-01

    Humans have dramatically altered landscapes as a result of urban and agricultural development, which has led to decreases in the quality and quantity of habitats for animals. This is particularly the case for freshwater fish that reside in fluvial systems, given that changes to adjacent lands have direct impacts on the structure and function of watersheds. Because choices of habitat have physiological consequences for organisms, animals that occupy sub-optimal habitats may experience increased expenditure of energy or homeostatic overload that can cause negative outcomes for individuals and populations. With the imperiled and threatened status of many freshwater fish, there is a critical need to define relationships between land use, quality of the habitat, and physiological performance for resident fish as an aid to restoration and management. Here, we synthesize existing literature to relate variation in land use at the scale of watersheds to the physiological status of resident fish. This examination revealed that landscape-level disturbances can influence a host of physiological properties of resident fishes, ranging from cellular and genomic levels to the hormonal and whole-animal levels. More importantly, these physiological responses have been integrated into traditional field-based monitoring protocols to provide a mechanistic understanding of how organisms interact with their environment, and to enhance restoration. We also generated a conceptual model that provides a basis for relating landscape-level changes to physiological responses in fish. We conclude that physiological sampling of resident fish has the potential to assess the effects of landscape-scale disturbances on freshwater fish and to enhance restoration and conservation. © The Author 2015. Published by Oxford University Press on behalf of the Society for Integrative and Comparative Biology. All rights reserved. For permissions please email: journals.permissions@oup.com.

  10. Monitoring Physiological Variables with Membrane Probes

    NASA Technical Reports Server (NTRS)

    Janle, Elsa M.

    1997-01-01

    This project has demonstrated the possibility of using membrane probes in rodents to monitor physiological variables for extended periods of time. The utility of these probes in physiological studies of microgravity has been demonstrated. The feasibility of developing on-line sensors has also been demonstrated and allows for the possibility of developing real-time automated monitoring systems which can be used in ground-base physiological research as well as in research and medical monitoring in space. In addition to space applications these techniques can be extended to medical monitoring in critical care situations on earth as well as facilitating research in many human and animal diseases.

  11. Comparing Phytophthora ramorum diagnostic protocols for the national Sudden Oak death stream monitoring program

    Treesearch

    W. Sutton; E.M. Hansen; P. Reeser; A. Kanaskie

    2008-01-01

    Oregon was a participant in the pilot test of the national stream monitoring protocol for SOD. We routinely and continuously monitor about 50 streams in and near the SOD quarantine area in southwest Oregon using foliage baits. For the national protocol, we added six additional streams beyond the area of known infestation, and compared results from different diagnostic...

  12. Intra-individual psychological and physiological responses to acute laboratory stressors of different intensity.

    PubMed

    Skoluda, Nadine; Strahler, Jana; Schlotz, Wolff; Niederberger, Larissa; Marques, Sofia; Fischer, Susanne; Thoma, Myriam V; Spoerri, Corinne; Ehlert, Ulrike; Nater, Urs M

    2015-01-01

    The phenomenon of stress is understood as a multidimensional concept which can be captured by psychological and physiological measures. There are various laboratory stress protocols which enable stress to be investigated under controlled conditions. However, little is known about whether these protocols differ with regard to the induced psycho-physiological stress response pattern. In a within-subjects design, 20 healthy young men underwent four of the most common stress protocols (Stroop test [Stroop], cold pressor test [CPT], Trier Social Stress Test [TSST], and bicycle ergometer test [Ergometer]) and a no-stress control condition (rest) in a randomized order. For the multidimensional assessment of the stress response, perceived stress, endocrine and autonomic biomarkers (salivary cortisol, salivary alpha-amylase, and heart rate) were obtained during the experiments. All stress protocols evoked increases in perceived stress levels, with the highest levels in the TSST, followed by Ergometer, Stroop, and CPT. The highest HPA axis response was found in the TSST, followed by Ergometer, CPT, and Stroop, whilst the highest autonomic response was found in the Ergometer, followed by TSST, Stroop, and CPT. These findings suggest that different stress protocols differentially stimulate various aspects of the stress response. Physically demanding stress protocols such as the Ergometer test appear to be particularly suitable for evoking autonomic stress responses, whereas uncontrollable and social-evaluative threatening stressors (such as the TSST) are most likely to elicit HPA axis stress responses. The results of this study may help researchers in deciding which stress protocol to use, depending on the individual research question. Copyright © 2014 Elsevier Ltd. All rights reserved.

  13. The effects of traditional, superset, and tri-set resistance training structures on perceived intensity and physiological responses.

    PubMed

    Weakley, Jonathon J S; Till, Kevin; Read, Dale B; Roe, Gregory A B; Darrall-Jones, Joshua; Phibbs, Padraic J; Jones, Ben

    2017-09-01

    Investigate the acute and short-term (i.e., 24 h) effects of traditional (TRAD), superset (SS), and tri-set (TRI) resistance training protocols on perceptions of intensity and physiological responses. Fourteen male participants completed a familiarisation session and three resistance training protocols (i.e., TRAD, SS, and TRI) in a randomised-crossover design. Rating of perceived exertion, lactate concentration ([Lac]), creatine kinase concentration ([CK]), countermovement jump (CMJ), testosterone, and cortisol concentrations was measured pre, immediately, and 24-h post the resistance training sessions with magnitude-based inferences assessing changes/differences within/between protocols. TRI reported possible to almost certainly greater efficiency and rate of perceived exertion, although session perceived load was very likely lower. SS and TRI had very likely to almost certainly greater lactate responses during the protocols, with changes in [CK] being very likely and likely increased at 24 h, respectively. At 24-h post-training, CMJ variables in the TRAD protocol had returned to baseline; however, SS and TRI were still possibly to likely reduced. Possible increases in testosterone immediately post SS and TRI protocols were reported, with SS showing possible increases at 24-h post-training. TRAD and SS showed almost certain and likely decreases in cortisol immediately post, respectively, with TRAD reporting likely decreases at 24-h post-training. SS and TRI can enhance training efficiency and reduce training time. However, acute and short-term physiological responses differ between protocols. Athletes can utilise SS and TRI resistance training, but may require additional recovery post-training to minimise effects of fatigue.

  14. Forest Soil Disturbance Monitoring Protocol: Volume I: Rapid assessment

    Treesearch

    Deborah S. Page-Dumroese; Ann M. Abbott; Thomas M. Rice

    2009-01-01

    This volume of the Forest Soil Disturbance Monitoring Protocol (FSDMP) describes how to monitor forest sites before and after ground disturbing management activities for physical attributes that could influence site resilience and long-term sustainability. The attributes describe surface conditions that affect site sustainability and hydrologic function. Monitoring the...

  15. National protocol framework for the inventory and monitoring of bees

    USGS Publications Warehouse

    Droege, Sam; Engler, Joseph D.; Sellers, Elizabeth A.; Lee O'Brien,

    2016-01-01

    This national protocol framework is a standardized tool for the inventory and monitoring of the approximately 4,200 species of native and non-native bee species that may be found within the National Wildlife Refuge System (NWRS) administered by the U.S. Fish and Wildlife Service (USFWS). However, this protocol framework may also be used by other organizations and individuals to monitor bees in any given habitat or location. Our goal is to provide USFWS stations within the NWRS (NWRS stations are land units managed by the USFWS such as national wildlife refuges, national fish hatcheries, wetland management districts, conservation areas, leased lands, etc.) with techniques for developing an initial baseline inventory of what bee species are present on their lands and to provide an inexpensive, simple technique for monitoring bees continuously and for monitoring and evaluating long-term population trends and management impacts. The latter long-term monitoring technique requires a minimal time burden for the individual station, yet can provide a good statistical sample of changing populations that can be investigated at the station, regional, and national levels within the USFWS’ jurisdiction, and compared to other sites within the United States and Canada. This protocol framework was developed in cooperation with the United States Geological Survey (USGS), the USFWS, and a worldwide network of bee researchers who have investigated the techniques and methods for capturing bees and tracking population changes. The protocol framework evolved from field and lab-based investigations at the USGS Bee Inventory and Monitoring Laboratory at the Patuxent Wildlife Research Center in Beltsville, Maryland starting in 2002 and was refined by a large number of USFWS, academic, and state groups. It includes a Protocol Introduction and a set of 8 Standard Operating Procedures or SOPs and adheres to national standards of protocol content and organization. The Protocol Narrative describes the history and need for the protocol framework and summarizes the basic elements of objectives, sampling design, field methods, training, data management, analysis, and reporting. The SOPs provide more detail and specific instructions for implementing the protocol framework. A central database, for managing all the resulting data is under development. We welcome use of this protocol framework by our partners, as appropriate for their bee inventory and monitoring objectives.

  16. Validation of Procedures for Monitoring Crewmember Immune Function

    NASA Technical Reports Server (NTRS)

    Crucian, Brian; Stowe, Raymond; Mehta, Satish; Uchakin, Peter; Quiriarte, Heather; Pierson, Duane; Sams, Clarence

    2008-01-01

    There is ample evidence to suggest that space flight leads to immune system dysregulation. This may be a result of microgravity, confinement, physiological stress, radiation, environment or other mission-associated factors. The clinical risk (if any) from prolonged immune dysregulation during exploration-class space flight has not yet been determined, but may include increased incidence of infection, allergy, hypersensitivity, hematological malignancy or altered wound healing. Each of the clinical events resulting from immune dysfunction has the potential to impact mission critical objectives during exploration-class missions. To date, precious little in-flight immune data has been generated to assess this phenomenon. The majority of recent flight immune studies have been post-flight assessments, which may not accurately reflect the in-flight status of immunity as it resolves over prolonged flight. There are no procedures currently in place to monitor immune function or its effect on crew health. The objective of this Supplemental Medical Objective (SMO) is to develop and validate an immune monitoring strategy consistent with operational flight requirements and constraints. This SMO will assess immunity, latent viral reactivation and physiological stress during both short and long duration flights. Upon completion, it is expected that any clinical risks resulting from the adverse effects of space flight on the human immune system will have been determined. In addition, a flight-compatible immune monitoring strategy will have been developed with which countermeasures validation could be performed. This study will determine, to the best level allowed by current technology, the in-flight status of crewmembers' immune systems. The in-flight samples will allow a distinction between legitimate in-flight alterations and the physiological stresses of landing and readaptation which are believed to alter R+0 assessments. The overall status of the immune system during flight (activation, deficiency, dysregulation) and the response of the immune system to specific latent virus reactivation (known to occur during space flight) will be thoroughly assessed. The first in-flight activity for integrated immunity very recently occurred during the STS-120 Space Shuttle mission. The protocols functioned well from a technical perspective, and accurate in-flight data was obtained from 1 Shuttle and 2 ISS crewmembers. Crew participation rates for the study continue to be robust.

  17. Maternal-Fetal Monitoring of Opioid-Exposed Pregnancies: Analysis of a Pilot Community-Based Protocol and Review of the Literature.

    PubMed

    Ryan, Gareth; Dooley, Joe; Windrim, Rory; Bollinger, Megan; Gerber Finn, Lianne; Kelly, Len

    2017-06-01

    To describe/analyse a novel, community-based prenatal monitoring protocol for opioid-exposed pregnancies developed by our centre in 2014 to optimize prenatal care for this population. A literature review of published monitoring protocols for this population is also presented. Retrospective comparison of pre-protocol (n = 215) and post-protocol (n = 251) cohorts. Medline and Embase were searched between 2000-2016 using MeSH terms: [fetal monitoring OR prenatal care] AND [opioid-related disorders OR substance-related disorders] in Medline and [fetal monitoring OR prenatal care] AND [opiate addiction OR substance abuse] in Embase, producing 518 results. Thirteen studies included protocols for monitoring opioid-exposed pregnancies. No comprehensive monitoring protocols with high-quality supporting evidence were found. We evaluated 466 opioid-exposed pregnancies, 215 before and 251 after introduction of the protocol. Since implementation, there was a significant increase in the number of opioid-exposed patients who have underwent urine drug screening (72.6% to 89.2%, P < 0.0001); a significant reduction in the number of urine drug screenings positive for illicit opioids (50.2% to 29.1%, P < 0.0001); and a significant increase in the number of patients who discontinued illicit opioid use by the time of delivery (24.7% to 39.4%, P < 0.01). There was no difference in the CS rate (27.4% vs. 26.3%, P > 0.05). There were no observed differences in the rate of preterm birth, birth weight <2500 g, or Apgar score <7 (P > 0.05). Care of women with increased opioid use during pregnancy is an important but under-studied health issue. A novel protocol for focused antenatal care provision for women with opioid-exposed pregnancies improves standard of care and maternal/fetal outcomes. Copyright © 2017. Published by Elsevier Inc.

  18. Pregnancy Research on Osteopathic Manipulation Optimizing Treatment Effects: The PROMOTE Study Protocol.

    PubMed

    Hensel, Kendi L; Carnes, Michael S; Stoll, Scott T

    2016-11-01

    The structural and physiologic changes in a woman's body during pregnancy can predispose pregnant women to low back pain and its associated disability, as well as to complications of pregnancy, labor, and delivery. Anecdotal and empirical evidence has indicated that osteopathic manipulative treatment (OMT) may be efficacious in improving pain and functionality in women who are pregnant. Based on that premise, the Pregnancy Research on Osteopathic Manipulation Optimizing Treatment Effects (PROMOTE) study was designed as a prospective, randomized, placebo-controlled, and blinded clinical trial to evaluate the efficacy of an OMT protocol for pain during third-trimester pregnancy. The OMT protocol developed for the PROMOTE study was based on physiologic theory and the concept of the interrelationship of structure and function. The 12 well-defined, standardized OMT techniques used in the protocol are commonly taught at osteopathic medical schools in the United States. These techniques can be easily replicated as a 20-minute protocol applied in conjunction with usual prenatal care, thus making it feasible to implement into clinical practice. This article presents an overview of the study design and treatment protocols used in the PROMOTE study.

  19. Automated, Quantitative Cognitive/Behavioral Screening of Mice: For Genetics, Pharmacology, Animal Cognition and Undergraduate Instruction

    PubMed Central

    Gallistel, C. R.; Balci, Fuat; Freestone, David; Kheifets, Aaron; King, Adam

    2014-01-01

    We describe a high-throughput, high-volume, fully automated, live-in 24/7 behavioral testing system for assessing the effects of genetic and pharmacological manipulations on basic mechanisms of cognition and learning in mice. A standard polypropylene mouse housing tub is connected through an acrylic tube to a standard commercial mouse test box. The test box has 3 hoppers, 2 of which are connected to pellet feeders. All are internally illuminable with an LED and monitored for head entries by infrared (IR) beams. Mice live in the environment, which eliminates handling during screening. They obtain their food during two or more daily feeding periods by performing in operant (instrumental) and Pavlovian (classical) protocols, for which we have written protocol-control software and quasi-real-time data analysis and graphing software. The data analysis and graphing routines are written in a MATLAB-based language created to simplify greatly the analysis of large time-stamped behavioral and physiological event records and to preserve a full data trail from raw data through all intermediate analyses to the published graphs and statistics within a single data structure. The data-analysis code harvests the data several times a day and subjects it to statistical and graphical analyses, which are automatically stored in the "cloud" and on in-lab computers. Thus, the progress of individual mice is visualized and quantified daily. The data-analysis code talks to the protocol-control code, permitting the automated advance from protocol to protocol of individual subjects. The behavioral protocols implemented are matching, autoshaping, timed hopper-switching, risk assessment in timed hopper-switching, impulsivity measurement, and the circadian anticipation of food availability. Open-source protocol-control and data-analysis code makes the addition of new protocols simple. Eight test environments fit in a 48 in x 24 in x 78 in cabinet; two such cabinets (16 environments) may be controlled by one computer. PMID:24637442

  20. Automated, quantitative cognitive/behavioral screening of mice: for genetics, pharmacology, animal cognition and undergraduate instruction.

    PubMed

    Gallistel, C R; Balci, Fuat; Freestone, David; Kheifets, Aaron; King, Adam

    2014-02-26

    We describe a high-throughput, high-volume, fully automated, live-in 24/7 behavioral testing system for assessing the effects of genetic and pharmacological manipulations on basic mechanisms of cognition and learning in mice. A standard polypropylene mouse housing tub is connected through an acrylic tube to a standard commercial mouse test box. The test box has 3 hoppers, 2 of which are connected to pellet feeders. All are internally illuminable with an LED and monitored for head entries by infrared (IR) beams. Mice live in the environment, which eliminates handling during screening. They obtain their food during two or more daily feeding periods by performing in operant (instrumental) and Pavlovian (classical) protocols, for which we have written protocol-control software and quasi-real-time data analysis and graphing software. The data analysis and graphing routines are written in a MATLAB-based language created to simplify greatly the analysis of large time-stamped behavioral and physiological event records and to preserve a full data trail from raw data through all intermediate analyses to the published graphs and statistics within a single data structure. The data-analysis code harvests the data several times a day and subjects it to statistical and graphical analyses, which are automatically stored in the "cloud" and on in-lab computers. Thus, the progress of individual mice is visualized and quantified daily. The data-analysis code talks to the protocol-control code, permitting the automated advance from protocol to protocol of individual subjects. The behavioral protocols implemented are matching, autoshaping, timed hopper-switching, risk assessment in timed hopper-switching, impulsivity measurement, and the circadian anticipation of food availability. Open-source protocol-control and data-analysis code makes the addition of new protocols simple. Eight test environments fit in a 48 in x 24 in x 78 in cabinet; two such cabinets (16 environments) may be controlled by one computer.

  1. Analysis of the proteolysis of bioactive peptides using a peptidomics approach

    PubMed Central

    Kim, Yun-Gon; Lone, Anna Mari; Saghatelian, Alan

    2014-01-01

    Identifying the peptidases that inactivate bioactive peptides (e.g. peptide hormones and neuropeptides) in mammals is an important unmet challenge. This protocol describes a recent approach that combines liquid chromatography-mass spectrometry peptidomics to identify endogenous cleavage sites of a bioactive peptide, the subsequent biochemical purification of a candidate peptidase based on these cleavage sites, and validation of the candidate peptidase’s role in the physiological regulation of the bioactive peptide by examining a peptidase knockout mouse. We highlight successful application of this protocol to discover that insulin-degrading enzyme (IDE) regulates physiological calcitonin gene-related peptide (CGRP) levels and detail the key stages and steps in this approach. This protocol requires 7 days of work; however, the total time for this protocol is highly variable because of its dependence on the availability of biological reagents, namely purified enzymes and knockout mice. The protocol is valuable because it expedites the characterization of mammalian peptidases, such as IDE, which in certain instances can be used to develop novel therapeutics. PMID:23949379

  2. Development of protocols to inventory or monitor wildlife, fish, or rare plants

    Treesearch

    David Vesely; Brenda C. McComb; Christina D. Vojta; Lowell H. Suring; Jurai Halaj; Richard S. Holthausen; Benjamin Zuckerberg; Patricia M. Manley

    2006-01-01

    The purpose of this technical guide (hereafter referred to as the Species Protocol Technical Guide) is to provide guidelines for developing inventory and monitoring (I&M) protocols for wildlife, fish, and rare plants (WFRP) using the U.S. Department of Agriculture (USDA) Forest Service technical guide format.

  3. An efficacious oral health care protocol for immunocompromised patients.

    PubMed

    Solomon, C S; Shaikh, A B; Arendorf, T M

    1995-01-01

    A twice-weekly oral and perioral examination was provided to 120 patients receiving antineoplastic therapy. Sixty patients were monitored while following the traditional hospital oral care protocol (chlorhexidine, hydrogen peroxide, sodium bicarbonate, thymol glycol, benzocaine mouthrinse, and nystatin). The mouth care protocol was then changed (experimental protocol = chlorhexidine, benzocaine lozenges, amphotericin B lozenges), and patients were monitored until the sample size matched that of the hospital mouth care regime. There was a statistically significant reduction in oral complications upon introduction and maintenance of the experimental protocol.

  4. Development of an Arm Phantom for Testing Non-Invasive Blood Pressure Monitors

    NASA Astrophysics Data System (ADS)

    Anderson-Jackson, LaTecia D.

    Approximately one in every three adults age 20 older are diagnosed with high blood pressure or hypertension. It is estimated that hypertension affects 78 million people in the United States, is equally prevalent in both men and woman (Crabtree, Stuart-Shor, & McAllister, 2013). In the United States, around 78% of people suffering from hypertension are aware of their condition, with only 68% using hypertensive medications to control their blood pressure (Writing Group et al., 2010). Clinically, blood pressure measurements may lack accuracy, which can be attributed to various factors, including device limitations, cuff mis-sizing and misplacement, white-coat effect, masked hypertension, and lifestyle factors. The development of an arm phantom to simulate physiologic properties of a human arm and arterial BP waveforms may allow us to better assess the accuracy of non-invasive blood pressure (NIBP) monitors. The objective of this study are to: (1) Develop an arm phantom to replicate physiological properties of the human arm, and (2) Incorporate the arm phantom into a mock circulatory flow loop to simulate different physiological blood pressure readings on the bench. A tissue mimicking material, styrene-ethylene-butylene-styrene (SEBS), a co-block polymer was used to develop the arm phantom for in-vitro testing. To determine the optimal mechanical properties for the arm phantom, individual arm components were isolated and tested. A protocol was developed to evaluate various components for optimal arm phantom development. Mechanical testing was conducted on 10%, 15%, and 20% SEBS gel samples for modulus of elasticity measurements in order to simulate physiological properties of the human arm. As a result of the SEBS polymer being a new material for this application, this investigation will contribute to resolving the limitations that occurred during experimentation. In this study, we demonstrated that although SEBS polymer may be an ideal material to use for simulating tissue, further research on the material properties should be conducted.

  5. Standardization of a Videofluoroscopic Swallow Study Protocol to Investigate Dysphagia in Dogs.

    PubMed

    Harris, R A; Grobman, M E; Allen, M J; Schachtel, J; Rawson, N E; Bennett, B; Ledyayev, J; Hopewell, B; Coates, J R; Reinero, C R; Lever, T E

    2017-03-01

    Videofluoroscopic swallow study (VFSS) is the gold standard for diagnosis of dysphagia in veterinary medicine but lacks standardized protocols that emulate physiologic feeding practices. Age impacts swallow function in humans but has not been evaluated by VFSS in dogs. To develop a protocol with custom kennels designed to allow free-feeding of 3 optimized formulations of contrast media and diets that address limitations of current VFSS protocols. We hypothesized that dogs evaluated by a free-feeding VFSS protocol would show differences in objective swallow metrics based on age. Healthy juvenile, adult, and geriatric dogs (n = 24). Prospective, experimental study. Custom kennels were developed to maintain natural feeding behaviors during VFSS. Three food consistencies (thin liquid, pureed food, and dry kibble) were formulated with either iohexol or barium to maximize palatability and voluntary prehension. Dogs were evaluated by 16 swallow metrics and compared across age groups. Development of a standardized VFSS protocol resulted in successful collection of swallow data in healthy dogs. No significant differences in swallow metrics were observed among age groups. Substantial variability was observed in healthy dogs when evaluated under these physiologic conditions. Features typically attributed to pathologic states, such as gastric reflux, were seen in healthy dogs. Development of a VFSS protocol that reflects natural feeding practices may allow emulation of physiology resulting in clinical signs of dysphagia. Age did not result in significant changes in swallow metrics, but additional studies are needed, particularly in light of substantial normal variation. Copyright © 2017 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.

  6. Long-term seafloor monitoring at an open ocean aquaculture site in the western Gulf of Maine, USA: development of an adaptive protocol.

    PubMed

    Grizzle, R E; Ward, L G; Fredriksson, D W; Irish, J D; Langan, R; Heinig, C S; Greene, J K; Abeels, H A; Peter, C R; Eberhardt, A L

    2014-11-15

    The seafloor at an open ocean finfish aquaculture facility in the western Gulf of Maine, USA was monitored from 1999 to 2008 by sampling sites inside a predicted impact area modeled by oceanographic conditions and fecal and food settling characteristics, and nearby reference sites. Univariate and multivariate analyses of benthic community measures from box core samples indicated minimal or no significant differences between impact and reference areas. These findings resulted in development of an adaptive monitoring protocol involving initial low-cost methods that required more intensive and costly efforts only when negative impacts were initially indicated. The continued growth of marine aquaculture is dependent on further development of farming methods that minimize negative environmental impacts, as well as effective monitoring protocols. Adaptive monitoring protocols, such as the one described herein, coupled with mathematical modeling approaches, have the potential to provide effective protection of the environment while minimize monitoring effort and costs. Copyright © 2014 Elsevier Ltd. All rights reserved.

  7. Standardized quality-assessment system to evaluate pressure ulcer care in the nursing home.

    PubMed

    Bates-Jensen, Barbara M; Cadogan, Mary; Jorge, Jennifer; Schnelle, John F

    2003-09-01

    To demonstrate reliability and feasibility of a standardized protocol to assess and score quality indicators relevant to pressure ulcer (PU) care processes in nursing homes (NHs). Descriptive. Eight NHs. One hundred ninety-one NH residents for whom the PU Resident Assessment Protocol of the Minimum Data Set was initiated. Nine quality indicators (two related to screening and prevention of PU, two focused on assessment, and five addressing management) were scored using medical record data, direct human observation, and wireless thigh monitor observation data. Feasibility and reliability of medical record, observation, and thigh monitor protocols were determined. The percentage of participants who passed each of the indicators, indicating care consistent with practice guidelines, ranged from 0% to 98% across all indicators. In general, participants in NHs passed fewer indicators and had more problems with medical record accuracy before a PU was detected (screening/prevention indicators) than they did once an ulcer was documented (assessment and management indicators). Reliability of the medical record protocol showed kappa statistics ranging from 0.689 to 1.00 and percentage agreement from 80% to 100%. Direct observation protocols yielded kappa statistics of 0.979 and 0.928. Thigh monitor protocols showed kappa statistics ranging from 0.609 to 0.842. Training was variable, with the observation protocol requiring 1 to 2 hours, medical records requiring joint review of 20 charts with average time to complete the review of 20 minutes, and the thigh monitor data requiring 1 week for training in data preparation and interpretation. The standardized quality assessment system generated scores for nine PU quality indicators with good reliability and provided explicit scoring rules that permit reproducible conclusions about PU care. The focus of the indicators on care processes that are under the control of NH staff made the protocol useful for external survey and internal quality improvement purposes, and the thigh monitor observational technology provided a method for monitoring repositioning care processes that were otherwise difficult to monitor and manage.

  8. NASA Exercise Physiology and Countermeasures Project Overview

    NASA Technical Reports Server (NTRS)

    Loerch, Linda; Ploutz-Snyder, Lori

    2009-01-01

    Efficient exercise countermeasures are necessary to offset or minimize spaceflight-induced deconditioning and to maximize crew performance of mission tasks. These countermeasure protocols should use the fewest crew and vehicle resources. NASA s Exercise Physiology and Countermeasures (ExPC) Project works to identify, collect, interpret, and summarize evidence that results in effective exercise countermeasure protocols which protect crew health and performance during International Space Station (ISS) and future exploration-class missions. The ExPC and NASA s Human Research Program are sponsoring multiple studies to evaluate and improve the efficacy of spaceflight exercise countermeasures. First, the Project will measure maximal aerobic capacity (VO2max) during cycle ergometry before, during, and after ISS missions. Second, the Project is sponsoring an evaluation of a new prototype harness that offers improved comfort and increased loading during treadmill operations. Third, the Functional Tasks Test protocol will map performance of anticipated lunar mission tasks with physiologic systems before and after short and long-duration spaceflight, to target system contributions and the tailoring of exercise protocols to maximize performance. In addition to these studies that are actively enrolling crewmember participants, the ExPC is planning new studies that include an evaluation of a higher-intensity/lower-volume exercise countermeasure protocol aboard the ISS using the Advanced Resistive Exercise Device and second-generation treadmill, studies that evaluate bone loading during spaceflight exercise, and ground-based studies that focus on fitness for duty standards required to complete lunar mission tasks and for which exercise protocols need to protect. Summaries of these current and future studies and strategies will be provided to international colleagues for knowledge sharing and possible collaboration.

  9. Status and trends monitoring of riparian and aquatic habitat in the Olympic Experimental State Forest: Monitoring protocols

    Treesearch

    Teodora Minkova; Alex D. Foster

    2017-01-01

    Presented here are the monitoring protocols for the Status and Trends Monitoring of Riparian and Aquatic Habitats project in the Olympic Experimental State Forest (OESF). The procedures yield the empirical data needed to address key uncertainties regarding the integration of timber production and habitat conservation across landscapes and assess progress toward...

  10. A Method of Managing Severe Traumatic Brain Injury in the Absence of Intracranial Pressure Monitoring: The Imaging and Clinical Examination Protocol.

    PubMed

    Chesnut, Randall M; Temkin, Nancy; Dikmen, Sureyya; Rondina, Carlos; Videtta, Walter; Petroni, Gustavo; Lujan, Silvia; Alanis, Victor; Falcao, Antonio; de la Fuenta, Gustavo; Gonzalez, Luis; Jibaja, Manuel; Lavarden, Arturo; Sandi, Freddy; Mérida, Roberto; Romero, Ricardo; Pridgeon, Jim; Barber, Jason; Machamer, Joan; Chaddock, Kelley

    2018-01-01

    The imaging and clinical examination (ICE) algorithm used in the Benchmark Evidence from South American Trials: Treatment of Intracranial Pressure (BEST TRIP) randomized controlled trial is the only prospectively investigated clinical protocol for traumatic brain injury management without intracranial pressure (ICP) monitoring. As the default literature standard, it warrants careful evaluation. We present the ICE protocol in detail and analyze the demographics, outcome, treatment intensity, frequency of intervention usage, and related adverse events in the ICE-protocol cohort. The 167 ICE protocol patients were young (median 29 years) with a median Glasgow Coma Scale motor score of 4 but with anisocoria or abnormal pupillary reactivity in 40%. This protocol produced outcomes not significantly different from those randomized to the monitor-based protocol (favorable 6-month extended Glasgow Outcome Score in 39%; 41% mortality rate). Agents commonly employed to treat suspected intracranial hypertension included low-/moderate-dose hypertonic saline (72%) and mannitol (57%), mild hyperventilation (adjusted partial pressure of carbon dioxide 30-35 mm Hg in 73%), and pressors to maintain cerebral perfusion (62%). High-dose hyperosmotics or barbiturates were uncommonly used. Adverse event incidence was low and comparable to the BEST TRIP monitored group. Although this protocol should produce similar/acceptable results under circumstances comparable to those in the trial, influences such as longer pre-hospital times and non-specialist transport personnel, plus an intensive care unit model of aggressive physician-intensive care by small groups of neurotrauma-focused intensivists, which differs from most high-resource models, support caution in expecting the same results in dissimilar settings. Finally, this protocol's ICP-titration approach to suspected intracranial hypertension (vs. crisis management for monitored ICP) warrants further study.

  11. Methods for Monitoring Fish Communities of Buffalo National River and Ozark National Scenic Riverways in the Ozark Plateaus of Arkansas and Missouri: Version 1.0

    USGS Publications Warehouse

    Petersen, James C.; Justus, B.G.; Dodd, H.R.; Bowles, D.E.; Morrison, L.W.; Williams, M.H.; Rowell, G.A.

    2008-01-01

    Buffalo National River located in north-central Arkansas, and Ozark National Scenic Riverways, located in southeastern Missouri, are the two largest units of the National Park Service in the Ozark Plateaus physiographic province. The purpose of this report is to provide a protocol that will be used by the National Park Service to sample fish communities and collect related water-quality, habitat, and stream discharge data of Buffalo National River and Ozark National Scenic Riverways to meet inventory and long-term monitoring objectives. The protocol includes (1) a protocol narrative, (2) several standard operating procedures, and (3) supplemental information helpful for implementation of the protocol. The protocol narrative provides background information about the protocol such as the rationale of why a particular resource or resource issue was selected for monitoring, information concerning the resource or resource issue of interest, a description of how monitoring results will inform management decisions, and a discussion of the linkages between this and other monitoring projects. The standard operating procedures cover preparation, training, reach selection, water-quality sampling, fish community sampling, physical habitat collection, measuring stream discharge, equipment maintenance and storage, data management and analysis, reporting, and protocol revision procedures. Much of the information in the standard operating procedures was gathered from existing protocols of the U.S. Geological Survey National Water Quality Assessment program or other sources. Supplemental information that would be helpful for implementing the protocol is included. This information includes information on fish species known or suspected to occur in the parks, sample sites, sample design, fish species traits, index of biotic integrity metrics, sampling equipment, and field forms.

  12. Challenges of physiological monitoring in a Navy operational setting

    NASA Technical Reports Server (NTRS)

    Banta, Guy R.

    1988-01-01

    Challenges to physiological monitoring in the Navy include environmental extremes, acceptance of use by test subjects, data transfer, data interpretation, and capability of relating collected data to valid operational relevant criterion measures. These problems are discussed with respect to diving, electrophysiological monitoring, in-flight monitoring, aircrew fatigue, in-flight cardiac stress, and in-flight monitoring devices.

  13. Learning temporal rules to forecast instability in continuously monitored patients

    PubMed Central

    Dubrawski, Artur; Wang, Donghan; Hravnak, Marilyn; Clermont, Gilles; Pinsky, Michael R

    2017-01-01

    Inductive machine learning, and in particular extraction of association rules from data, has been successfully used in multiple application domains, such as market basket analysis, disease prognosis, fraud detection, and protein sequencing. The appeal of rule extraction techniques stems from their ability to handle intricate problems yet produce models based on rules that can be comprehended by humans, and are therefore more transparent. Human comprehension is a factor that may improve adoption and use of data-driven decision support systems clinically via face validity. In this work, we explore whether we can reliably and informatively forecast cardiorespiratory instability (CRI) in step-down unit (SDU) patients utilizing data from continuous monitoring of physiologic vital sign (VS) measurements. We use a temporal association rule extraction technique in conjunction with a rule fusion protocol to learn how to forecast CRI in continuously monitored patients. We detail our approach and present and discuss encouraging empirical results obtained using continuous multivariate VS data from the bedside monitors of 297 SDU patients spanning 29 346 hours (3.35 patient-years) of observation. We present example rules that have been learned from data to illustrate potential benefits of comprehensibility of the extracted models, and we analyze the empirical utility of each VS as a potential leading indicator of an impending CRI event. PMID:27274020

  14. Monitoring fish distributions along electrofishing segments

    USGS Publications Warehouse

    Miranda, Leandro E.

    2014-01-01

    Electrofishing is widely used to monitor fish species composition and relative abundance in streams and lakes. According to standard protocols, multiple segments are selected in a body of water to monitor population relative abundance as the ratio of total catch to total sampling effort. The standard protocol provides an assessment of fish distribution at a macrohabitat scale among segments, but not within segments. An ancillary protocol was developed for assessing fish distribution at a finer scale within electrofishing segments. The ancillary protocol was used to estimate spacing, dispersion, and association of two species along shore segments in two local reservoirs. The added information provided by the ancillary protocol may be useful for assessing fish distribution relative to fish of the same species, to fish of different species, and to environmental or habitat characteristics.

  15. A wearable physiological sensor suite for unobtrusive monitoring of physiological and cognitive state.

    PubMed

    Matthews, Robert; McDonald, Neil J; Hervieux, Paul; Turner, Peter J; Steindorf, Martin A

    2007-01-01

    This paper describes an integrated Physiological Sensor Suite (PSS) based upon QUASAR's innovative non-invasive bioelectric sensor technologies that will provide, for the first time, a fully integrated, noninvasive methodology for physiological sensing. The PSS currently under development at QUASAR is a state-of-the-art multimodal array of sensors that, along with an ultra-low power personal area wireless network, form a comprehensive body-worn system for real-time monitoring of subject physiology and cognitive status. Applications of the PSS extend from monitoring of military personnel to long-term monitoring of patients diagnosed with cardiac or neurological conditions. Results for side-by-side comparisons between QUASAR's biosensor technology and conventional wet electrodes are presented. The signal fidelity for bioelectric measurements using QUASAR's biosensors is comparable to that for wet electrodes.

  16. Optoacoustic Monitoring of Physiologic Variables

    PubMed Central

    Esenaliev, Rinat O.

    2017-01-01

    Optoacoustic (photoacoustic) technique is a novel diagnostic platform that can be used for noninvasive measurements of physiologic variables, functional imaging, and hemodynamic monitoring. This technique is based on generation and time-resolved detection of optoacoustic (thermoelastic) waves generated in tissue by short optical pulses. This provides probing of tissues and individual blood vessels with high optical contrast and ultrasound spatial resolution. Because the optoacoustic waves carry information on tissue optical and thermophysical properties, detection, and analysis of the optoacoustic waves allow for measurements of physiologic variables with high accuracy and specificity. We proposed to use the optoacoustic technique for monitoring of a number of important physiologic variables including temperature, thermal coagulation, freezing, concentration of molecular dyes, nanoparticles, oxygenation, and hemoglobin concentration. In this review we present origin of contrast and high spatial resolution in these measurements performed with optoacoustic systems developed and built by our group. We summarize data obtained in vitro, in experimental animals, and in humans on monitoring of these physiologic variables. Our data indicate that the optoacoustic technology may be used for monitoring of cerebral blood oxygenation in patients with traumatic brain injury and in neonatal patients, central venous oxygenation monitoring, total hemoglobin concentration monitoring, hematoma detection and characterization, monitoring of temperature, and coagulation and freezing boundaries during thermotherapy. PMID:29311964

  17. Optoacoustic Monitoring of Physiologic Variables.

    PubMed

    Esenaliev, Rinat O

    2017-01-01

    Optoacoustic (photoacoustic) technique is a novel diagnostic platform that can be used for noninvasive measurements of physiologic variables, functional imaging, and hemodynamic monitoring. This technique is based on generation and time-resolved detection of optoacoustic (thermoelastic) waves generated in tissue by short optical pulses. This provides probing of tissues and individual blood vessels with high optical contrast and ultrasound spatial resolution. Because the optoacoustic waves carry information on tissue optical and thermophysical properties, detection, and analysis of the optoacoustic waves allow for measurements of physiologic variables with high accuracy and specificity. We proposed to use the optoacoustic technique for monitoring of a number of important physiologic variables including temperature, thermal coagulation, freezing, concentration of molecular dyes, nanoparticles, oxygenation, and hemoglobin concentration. In this review we present origin of contrast and high spatial resolution in these measurements performed with optoacoustic systems developed and built by our group. We summarize data obtained in vitro , in experimental animals, and in humans on monitoring of these physiologic variables. Our data indicate that the optoacoustic technology may be used for monitoring of cerebral blood oxygenation in patients with traumatic brain injury and in neonatal patients, central venous oxygenation monitoring, total hemoglobin concentration monitoring, hematoma detection and characterization, monitoring of temperature, and coagulation and freezing boundaries during thermotherapy.

  18. Emerging technologies for pediatric and adult trauma care.

    PubMed

    Moulton, Steven L; Haley-Andrews, Stephanie; Mulligan, Jane

    2010-06-01

    Current Emergency Medical Service protocols rely on provider-directed care for evaluation, management and triage of injured patients from the field to a trauma center. New methods to quickly diagnose, support and coordinate the movement of trauma patients from the field to the most appropriate trauma center are in development. These methods will enhance trauma care and promote trauma system development. Recent advances in machine learning, statistical methods, device integration and wireless communication are giving rise to new methods for vital sign data analysis and a new generation of transport monitors. These monitors will collect and synchronize exponentially growing amounts of vital sign data with electronic patient care information. The application of advanced statistical methods to these complex clinical data sets has the potential to reveal many important physiological relationships and treatment effects. Several emerging technologies are converging to yield a new generation of smart sensors and tightly integrated transport monitors. These technologies will assist prehospital providers in quickly identifying and triaging the most severely injured children and adults to the most appropriate trauma centers. They will enable the development of real-time clinical support systems of increasing complexity, able to provide timelier, more cost-effective, autonomous care.

  19. Ubiquitous computing in sports: A review and analysis.

    PubMed

    Baca, Arnold; Dabnichki, Peter; Heller, Mario; Kornfeind, Philipp

    2009-10-01

    Ubiquitous (pervasive) computing is a term for a synergetic use of sensing, communication and computing. Pervasive use of computing has seen a rapid increase in the current decade. This development has propagated in applied sport science and everyday life. The work presents a survey of recent developments in sport and leisure with emphasis on technology and computational techniques. A detailed analysis on new technological developments is performed. Sensors for position and motion detection, and such for equipment and physiological monitoring are discussed. Aspects of novel trends in communication technologies and data processing are outlined. Computational advancements have started a new trend - development of smart and intelligent systems for a wide range of applications - from model-based posture recognition to context awareness algorithms for nutrition monitoring. Examples particular to coaching and training are discussed. Selected tools for monitoring rules' compliance and automatic decision-making are outlined. Finally, applications in leisure and entertainment are presented, from systems supporting physical activity to systems providing motivation. It is concluded that the emphasis in future will shift from technologies to intelligent systems that allow for enhanced social interaction as efforts need to be made to improve user-friendliness and standardisation of measurement and transmission protocols.

  20. Hypnosis for hot flashes among postmenopausal women study: A study protocol of an ongoing randomized clinical trial

    PubMed Central

    2011-01-01

    Background Hot flashes are a highly prevalent problem associated with menopause and breast cancer treatments. The recent findings from the Women's Health Initiative have important implications for the significance of a non-hormonal, mind-body intervention for hot flashes in breast cancer survivors. Women who take hormone therapy long-term may have a 1.2 to 2.0 fold increased risk of developing breast cancer. In addition, it is now known that hormone therapy with estrogen and progestin is associated with increased risk of cardiovascular disease and stroke. Currently there are limited options to hormone replacement therapy as non-hormonal pharmacological agents are associated with only modest activity and many adverse side effects. Because of this there is a need for more alternative, non-hormonal therapies. Hypnosis is a mind-body intervention that has been shown to reduce self-reported hot flashes by up to 68% among breast cancer survivors, however, the use of hypnosis for hot flashes among post-menopausal women has not been adequately explored and the efficacy of hypnosis in reducing physiologically measured hot flashes has not yet been determined. Methods/design A sample of 180 post-menopausal women will be randomly assigned to either a 5-session Hypnosis Intervention or 5-session structured-attention control with 12 week follow-up. The present study will compare hypnosis to a structured-attention control in reducing hot flashes (perceived and physiologically monitored) in post-menopausal women in a randomized clinical trial. Outcomes will be hot flashes (self-report daily diaries; physiological monitoring; Hot Flash Related Daily Interference Scale), anxiety (State-Trait Anxiety Inventory; Hospital Anxiety and Depression Scale (HADS); anxiety visual analog scale (VAS rating); depression (Center for Epidemiologic Studies Depression Scale), sexual functioning (Sexual Activity Questionnaire), sleep quality (Pittsburgh Sleep Quality Index) and cortisol. Discussion This study will be the first full scale test of hypnosis for hot flashes; one of the first studies to examine both perceived impact and physiologically measured impact of a mind-body intervention for hot flashes using state-of-the-art 24 hour ambulatory physiological monitoring; the first study to examine the effect of hypnosis for hot flashes on cortisol; and the first investigation of the role of cognitive expectancies in treatment of hot flashes in comparison to a Structured-Attention Control. Trial Registration This clinical trial has been registered with ClinicalTrials.gov, a service of the U.S. National Institutes of Health, ClinicalTrials.gov Identifier: NCT01293695. PMID:21989181

  1. A network monitor for HTTPS protocol based on proxy

    NASA Astrophysics Data System (ADS)

    Liu, Yangxin; Zhang, Lingcui; Zhou, Shuguang; Li, Fenghua

    2016-10-01

    With the explosive growth of harmful Internet information such as pornography, violence, and hate messages, network monitoring is essential. Traditional network monitors is based mainly on bypass monitoring. However, we can't filter network traffic using bypass monitoring. Meanwhile, only few studies focus on the network monitoring for HTTPS protocol. That is because HTTPS data is in the encrypted traffic, which makes it difficult to monitor. This paper proposes a network monitor for HTTPS protocol based on proxy. We adopt OpenSSL to establish TLS secure tunes between clients and servers. Epoll is used to handle a large number of concurrent client connections. We also adopt Knuth- Morris-Pratt string searching algorithm (or KMP algorithm) to speed up the search process. Besides, we modify request packets to reduce the risk of errors and modify response packets to improve security. Experiments show that our proxy can monitor the content of all tested HTTPS websites efficiently with little loss of network performance.

  2. An Efficient and Reproducible Protocol for Distraction Osteogenesis in a Rat Model Leading to a Functional Regenerated Femur.

    PubMed

    Pithioux, Martine; Roseren, Flavy; Jalain, Christian; Launay, Franck; Charpiot, Philippe; Chabrand, Patrick; Roffino, Sandrine; Lamy, Edouard

    2017-10-23

    This protocol describes the use of a newly developed external fixator for distraction osteogenesis in a rat femoral model. Distraction osteogenesis (DO) is a surgical technique leading to bone regeneration after an osteotomy. The osteotomized extremities are moved away from each other by gradual distraction to reach the desired elongation. This procedure is widely used in humans for lower and upper limb lengthening, treatment after a bone nonunion, or the regeneration of a bone defect following surgery for bone tumor excision, as well as in maxillofacial reconstruction. Only a few studies clearly demonstrate the efficiency of their protocol in obtaining a functional regenerated bone, i.e., bone that will support physiological weight-bearing without fracture after removal of the external fixator. Moreover, protocols for DO vary and reproducibility is limited by lack of information, making comparison between studies difficult. The aim of this study was to develop a reproducible protocol comprising an appropriate external fixator design for rat limb lengthening, with a detailed surgical technique that permits physiological weight-bearing by the animal after removal of the external fixator.

  3. Forest Soil Disturbance Monitoring Protocol: Volume II: Supplementary methods, statistics, and data collection

    Treesearch

    Deborah S. Page-Dumroese; Ann M. Abbott; Thomas M. Rice

    2009-01-01

    Volume I and volume II of the Forest Soil Disturbance Monitoring Protocol (FSDMP) provide information for a wide range of users, including technicians, field crew leaders, private landowners, land managers, forest professionals, and researchers. Volume I: Rapid Assessment includes the basic methods for establishing forest soil monitoring transects and consistently...

  4. A field protocol to monitor cavity-nesting birds

    Treesearch

    J. Dudley; V. Saab

    2003-01-01

    We developed a field protocol to monitor populations of cavity-nesting birds in burned and unburned coniferous forests of western North America. Standardized field methods are described for implementing long-term monitoring strategies and for conducting field research to evaluate the effects of habitat change on cavity-nesting birds. Key references (but not...

  5. Monitoring wilderness stream ecosystems

    Treesearch

    Jeffrey C. Davis; G. Wayne Minshall; Christopher T. Robinson; Peter Landres

    2001-01-01

    A protocol and methods for monitoring the major physical, chemical, and biological components of stream ecosystems are presented. The monitoring protocol is organized into four stages. At stage 1 information is obtained on a basic set of parameters that describe stream ecosystems. Each following stage builds upon stage 1 by increasing the number of parameters and the...

  6. SU-F-R-11: Designing Quality and Safety Informatics Through Implementation of a CT Radiation Dose Monitoring Program

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wilson, JM; Samei, E; Departments of Physics, Electrical and Computer Engineering, and Biomedical Engineering, and Medical Physics Graduate Program, Duke University, Durham, NC

    2016-06-15

    Purpose: Recent legislative and accreditation requirements have driven rapid development and implementation of CT radiation dose monitoring solutions. Institutions must determine how to improve quality, safety, and consistency of their clinical performance. The purpose of this work was to design a strategy and meaningful characterization of results from an in-house, clinically-deployed dose monitoring solution. Methods: A dose monitoring platform was designed by our imaging physics group that focused on extracting protocol parameters, dose metrics, and patient demographics and size. Compared to most commercial solutions, which focus on individual exam alerts and global thresholds, the program sought to characterize overall consistencymore » and targeted thresholds based on eight analytic interrogations. Those were based on explicit questions related to protocol application, national benchmarks, protocol and size-specific dose targets, operational consistency, outliers, temporal trends, intra-system variability, and consistent use of electronic protocols. Using historical data since the start of 2013, 95% and 99% intervals were used to establish yellow and amber parameterized dose alert thresholds, respectively, as a function of protocol, scanner, and size. Results: Quarterly reports have been generated for three hospitals for 3 quarters of 2015 totaling 27880, 28502, 30631 exams, respectively. Four adult and two pediatric protocols were higher than external institutional benchmarks. Four protocol dose levels were being inconsistently applied as a function of patient size. For the three hospitals, the minimum and maximum amber outlier percentages were [1.53%,2.28%], [0.76%,1.8%], [0.94%,1.17%], respectively. Compared with the electronic protocols, 10 protocols were found to be used with some inconsistency. Conclusion: Dose monitoring can satisfy requirements with global alert thresholds and patient dose records, but the real value is in optimizing patient-specific protocols, balancing image quality trade-offs that dose-reduction strategies promise, and improving the performance and consistency of a clinical operation. Data plots that capture patient demographics and scanner performance demonstrate that value.« less

  7. EPA Protocol Gas Verification Program

    EPA Science Inventory

    Accurate compressed gas calibration standards are needed to calibrate continuous emission monitors (CEMs) and ambient air quality monitors that are being used for regulatory purposes. US Environmental Protection Agency (EPA) established its traceability protocol to ensure that co...

  8. MyAirCoach: the use of home-monitoring and mHealth systems to predict deterioration in asthma control and the occurrence of asthma exacerbations; study protocol of an observational study

    PubMed Central

    Honkoop, Persijn J; Simpson, Andrew; Bonini, Matteo; Snoeck-Stroband, Jiska B; Meah, Sally; Fan Chung, Kian; Usmani, Omar S; Fowler, Stephen; Sont, Jacob K

    2017-01-01

    Introduction Asthma is a variable lung condition whereby patients experience periods of controlled and uncontrolled asthma symptoms. Patients who experience prolonged periods of uncontrolled asthma have a higher incidence of exacerbations and increased morbidity and mortality rates. The ability to determine and to predict levels of asthma control and the occurrence of exacerbations is crucial in asthma management. Therefore, we aimed to determine to what extent physiological, behavioural and environmental data, obtained by mobile healthcare (mHealth) and home-monitoring sensors, as well as patient characteristics, can be used to predict episodes of uncontrolled asthma and the onset of asthma exacerbations. Methods and analysis In an 1-year observational study, patients will be provided with mHealth and home-monitoring systems to record daily measurements for the first-month (phase I) and weekly measurements during a follow-up period of 11 months (phase II). Our study population consists of 150 patients, aged ≥18 years, with a clinician's diagnosis of asthma, currently on controller medication, with uncontrolled asthma and/or minimally one exacerbation in the past 12 months. They will be enrolled over three participating centres, including Leiden, London and Manchester. Our main outcomes are the association between physiological, behavioural and environmental data and (1) the loss of asthma control and (2) the occurrence of asthma exacerbations. Ethics This study was approved by the Medical Ethics Committee of the Leiden University Medical Center in the Netherlands and by the NHS ethics service in the UK. Trial registration number NCT02774772. PMID:28119390

  9. MyAirCoach: the use of home-monitoring and mHealth systems to predict deterioration in asthma control and the occurrence of asthma exacerbations; study protocol of an observational study.

    PubMed

    Honkoop, Persijn J; Simpson, Andrew; Bonini, Matteo; Snoeck-Stroband, Jiska B; Meah, Sally; Fan Chung, Kian; Usmani, Omar S; Fowler, Stephen; Sont, Jacob K

    2017-01-24

    Asthma is a variable lung condition whereby patients experience periods of controlled and uncontrolled asthma symptoms. Patients who experience prolonged periods of uncontrolled asthma have a higher incidence of exacerbations and increased morbidity and mortality rates. The ability to determine and to predict levels of asthma control and the occurrence of exacerbations is crucial in asthma management. Therefore, we aimed to determine to what extent physiological, behavioural and environmental data, obtained by mobile healthcare (mHealth) and home-monitoring sensors, as well as patient characteristics, can be used to predict episodes of uncontrolled asthma and the onset of asthma exacerbations. In an 1-year observational study, patients will be provided with mHealth and home-monitoring systems to record daily measurements for the first-month (phase I) and weekly measurements during a follow-up period of 11 months (phase II). Our study population consists of 150 patients, aged ≥18 years, with a clinician's diagnosis of asthma, currently on controller medication, with uncontrolled asthma and/or minimally one exacerbation in the past 12 months. They will be enrolled over three participating centres, including Leiden, London and Manchester. Our main outcomes are the association between physiological, behavioural and environmental data and (1) the loss of asthma control and (2) the occurrence of asthma exacerbations. This study was approved by the Medical Ethics Committee of the Leiden University Medical Center in the Netherlands and by the NHS ethics service in the UK. NCT02774772. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  10. Automated acquisition system for routine, noninvasive monitoring of physiological data.

    PubMed

    Ogawa, M; Tamura, T; Togawa, T

    1998-01-01

    A fully automated, noninvasive data-acquisition system was developed to permit long-term measurement of physiological functions at home, without disturbing subjects' normal routines. The system consists of unconstrained monitors built into furnishings and structures in a home environment. An electrocardiographic (ECG) monitor in the bathtub measures heart function during bathing, a temperature monitor in the bed measures body temperature, and a weight monitor built into the toilet serves as a scale to record weight. All three monitors are connected to one computer and function with data-acquisition programs and a data format rule. The unconstrained physiological parameter monitors and fully automated measurement procedures collect data noninvasively without the subject's awareness. The system was tested for 1 week by a healthy male subject, aged 28, in laboratory-based facilities.

  11. Role of Large Clinical Datasets From Physiologic Monitors in Improving the Safety of Clinical Alarm Systems and Methodological Considerations: A Case From Philips Monitors.

    PubMed

    Sowan, Azizeh Khaled; Reed, Charles Calhoun; Staggers, Nancy

    2016-09-30

    Large datasets of the audit log of modern physiologic monitoring devices have rarely been used for predictive modeling, capturing unsafe practices, or guiding initiatives on alarm systems safety. This paper (1) describes a large clinical dataset using the audit log of the physiologic monitors, (2) discusses benefits and challenges of using the audit log in identifying the most important alarm signals and improving the safety of clinical alarm systems, and (3) provides suggestions for presenting alarm data and improving the audit log of the physiologic monitors. At a 20-bed transplant cardiac intensive care unit, alarm data recorded via the audit log of bedside monitors were retrieved from the server of the central station monitor. Benefits of the audit log are many. They include easily retrievable data at no cost, complete alarm records, easy capture of inconsistent and unsafe practices, and easy identification of bedside monitors missed from a unit change of alarm settings adjustments. Challenges in analyzing the audit log are related to the time-consuming processes of data cleaning and analysis, and limited storage and retrieval capabilities of the monitors. The audit log is a function of current capabilities of the physiologic monitoring systems, monitor's configuration, and alarm management practices by clinicians. Despite current challenges in data retrieval and analysis, large digitalized clinical datasets hold great promise in performance, safety, and quality improvement. Vendors, clinicians, researchers, and professional organizations should work closely to identify the most useful format and type of clinical data to expand medical devices' log capacity.

  12. Terrestrial vegetation monitoring protocol for the Mediterranean Coast Network—Cabrillo National Monument, Channel Islands National Park, and Santa Monica Mountains National Recreation Area: Standard Operating Procedures, Version 1.0

    USGS Publications Warehouse

    Tiszler, John; Rodriguez, Dirk; Lombardo, Keith; Sagar, Tarja; Aguilar, Luis; Lee, Lena; Handley, Timothy; McEachern, A. Kathryn; Harrod Starcevich, Leigh Ann; Witter, Marti; Philippi, Tom; Ostermann-Kelm, Stacey

    2016-01-01

    These Standard Operating Procedures are one part of a two-part protocol for monitoring terrestrial vegetation in the Mediterranean Coast Network. The second part of the protocol is the narrative:Tiszler, J., D. Rodriguez, K. Lombardo, T. Sagar, L. Aguilar, L. Lee, T. Handley, K. McEachern, L. Starcevich, M. Witter, T. Philippi, and S. Ostermann-Kelm. 2016. Terrestrial vegetation monitoring protocol for the Mediterranean Coast Network—Cabrillo National Monument, Channel Islands National Park, and Santa Monica Mountains National Recreation Area: Narrative, version 1.0. Natural Resource Report NPS/MEDN/NRR—2016/1296. National Park Service, Fort Collins, Colorado.National parks in the Mediterranean Inventory and Monitoring Network:Cabrillo National Monument (CABR)Channel Islands National Park (CHIS)Santa Monica Mountains National Recreation Area (SAMO)

  13. IoT real time data acquisition using MQTT protocol

    NASA Astrophysics Data System (ADS)

    Atmoko, R. A.; Riantini, R.; Hasin, M. K.

    2017-05-01

    The Internet of Things (IoT) provides ease to monitor and to gain sensor data through the Internet [1]. The need of high quality data is increasing to the extent that data monitoring and acquisition system in real time is required, such as smart city or telediagnostic in medical areas [2]. Therefore, an appropriate communication protocol is required to resolve these problems. Lately, researchers have developed a lot of communication protocols for IoT, of which each has advantages and disadvantages. This study proposes the utilization of MQTT as a communication protocol, which is one of data communication protocols for IoT. This study used temperature and humidity sensors because the physical parameters are often needed as parameters of environment condition [3]. Data acquisition was done in real-time and stored in MySQL database. This study is also completed by interface web-based and mobile for online monitoring. This result of this study is the enhancement of data quality and reliability using MQTT protocol.

  14. Evidence supporting the need for a common soil monitoring protocol

    Treesearch

    Derrick A. Reeves; Mark D. Coleman; Deborah S. Page-Dumroese

    2013-01-01

    Many public land management agencies monitor forest soils for levels of disturbance related to management activities. Although several soil disturbance monitoring protocols based on visual observation have been developed to assess the amount and types of disturbance caused by forest management, no common method is currently used on National Forest lands in the United...

  15. An inventory and monitoring plan for a Sonoran Desert ecosystem; Barry M. Goldwater Range-West

    USGS Publications Warehouse

    Villarreal, Miguel L.; van Riper, Charles; Lovich, Robert E.; Palmer, Robert L.; Nauman, Travis; Studd, Sarah E.; Drake, Sam; Rosenberg, Abigail S.; Malusa, Jim; Pearce, Ronald L.

    2011-01-01

    Marine Corps Air Station Yuma manages the Barry M. Goldwater Range-West, which encompasses approximately 2,800 square kilometers of Sonoran Desert habitat in southwestern Arizona. The Barry M. Goldwater Range is a major U.S. military installation designed as an air combat training location for the U.S. Marine Corps and U.S. Air Force, but it also includes some of the most pristine desert habitat in the United States. In an effort to ensure the long-term viability of this unique natural resource, the U.S. Geological Survey (USGS) has developed an Integrated Natural Resources Management Plan and Inventory and Monitoring Plan to guide natural resource management of the Barry M. Goldwater Range-West. This Inventory and Monitoring Plan provides a framework for long-term ecosystem monitoring on Barry M. Goldwater Range-West lands by identifying existing and potential threats to ecosystem function, prioritizing resources for monitoring, and providing information and protocols necessary to initiate a long-term ecosystem monitoring program. The Inventory and Monitoring Plan and related protocols were developed through extensive review of existing Sonoran Desert monitoring programs and monitoring literature and through a 2-day workshop with resource managers, monitoring experts, and other stakeholders. The Barry M. Goldwater Range-West Inventory and Monitoring Plan stresses the importance of regional monitoring partnerships and protocol standardization for understanding landscape-scale ecosystem changes in the Sonoran Desert; information and protocols contained within the plan may also be of interest to land managers engaged in large-scale ecosystem monitoring and adaptive management of other arid regions.

  16. Sedation in the neurologic intensive care unit.

    PubMed

    Keegan, Mark T

    2008-03-01

    Providing adequate sedation in the neurologic intensive care unit (ICU) depends on determination of proper goals for sedation, adequate assessment of the level of sedation, and appropriate choice of drug based on the patient's physiology. The management of sedation in the ICU will influence long-term outcome. Delirium, anxiety, and pain must be identified and treated separately. The use of protocols can improve compliance with published evidence-based recommendations. Propofol and dexmedetomidine may be used for rapidly titratable sedation, benzodiazepines for anxiolysis, neuroleptics for treatment of delirium, and opiates for analgesia. Unique aspects of patients with acute brain disease, such as elevated intracranial pressure or status epilepticus, require adaptation of sedative regimens. Processed EEG monitoring and volatile anesthetic agents have not yet proven beneficial or practical for use in the ICU.

  17. A review of current timed-AI (TAI) programs for beef and dairy cattle

    PubMed Central

    Colazo, Marcos G.; Mapletoft, Reuben J.

    2014-01-01

    This is a review of the physiology and endocrinology of the estrous cycle and how ovarian physiology can be manipulated and controlled for timed artificial insemination (TAI) in beef and dairy cattle. Estrus detection is required for artificial insemination (AI), but it is done poorly in dairy cattle and it is difficult in beef cattle. Protocols that synchronize follicle growth, corpus luteum regression and ovulation, allowing for TAI, result in improved reproductive performance, because all animals are inseminated whether they show estrus or not. As result, TAI programs have become an integral part of reproductive management in many dairy herds and offer beef producers the opportunity to incorporate AI into their herds. Gonadotropin-releasing hormone-based protocols are commonly used in North America for estrus synchronization as part of a TAI program. Protocols that increase pregnancy rates in lactating dairy cows and suckling beef cows have been developed. Protocols that improve pregnancy rates in heifers, acyclic beef cows, and resynchronized lactating dairy cows are also discussed. PMID:25082993

  18. A review of current timed-AI (TAI) programs for beef and dairy cattle.

    PubMed

    Colazo, Marcos G; Mapletoft, Reuben J

    2014-08-01

    This is a review of the physiology and endocrinology of the estrous cycle and how ovarian physiology can be manipulated and controlled for timed artificial insemination (TAI) in beef and dairy cattle. Estrus detection is required for artificial insemination (AI), but it is done poorly in dairy cattle and it is difficult in beef cattle. Protocols that synchronize follicle growth, corpus luteum regression and ovulation, allowing for TAI, result in improved reproductive performance, because all animals are inseminated whether they show estrus or not. As result, TAI programs have become an integral part of reproductive management in many dairy herds and offer beef producers the opportunity to incorporate AI into their herds. Gonadotropin-releasing hormone-based protocols are commonly used in North America for estrus synchronization as part of a TAI program. Protocols that increase pregnancy rates in lactating dairy cows and suckling beef cows have been developed. Protocols that improve pregnancy rates in heifers, acyclic beef cows, and resynchronized lactating dairy cows are also discussed.

  19. The Functional Task Test (FTT): An Interdisciplinary Testing Protocol to Investigate the Factors Underlying Changes in Astronaut Functional Performance

    NASA Technical Reports Server (NTRS)

    Bloomberg, J. J.; Lawrence, E. L.; Arzeno, N. M.; Buxton, R. E.; Feiveson, A. H.; Kofman, I. S.; Lee, S. M. C.; Mulavara, A. P.; Peters, B. T.; Platts. S. H.; hide

    2011-01-01

    Exposure to space flight causes adaptations in multiple physiological systems including changes in sensorimotor, cardiovascular, and neuromuscular systems. These changes may affect a crewmember s ability to perform critical mission tasks immediately after landing on a planetary surface. The overall goal of this project is to determine the effects of space flight on functional tests that are representative of high priority exploration mission tasks and to identify the key underlying physiological factors that contribute to decrements in performance. To achieve this goal we developed an interdisciplinary testing protocol (Functional Task Test, FTT) that evaluates both astronaut functional performance and related physiological changes. Functional tests include ladder climbing, hatch opening, jump down, manual manipulation of objects and tool use, seat egress and obstacle avoidance, recovery from a fall and object translation tasks. Physiological measures include assessments of postural and gait control, dynamic visual acuity, fine motor control, plasma volume, orthostatic intolerance, upper- and lower-body muscle strength, power, endurance, control, and neuromuscular drive. Crewmembers perform this integrated test protocol before and after short (Shuttle) and long-duration (ISS) space flight. Data are collected on two sessions before flight, on landing day (Shuttle only) and 1, 6 and 30 days after landing. Preliminary results from both Shuttle and ISS crewmembers indicate decrement in performance of the functional tasks after both short and long-duration space flight. On-going data collection continues to improve the statistical power required to map changes in functional task performance to alterations in physiological systems. The information obtained from this study will be used to design and implement countermeasures that specifically target the physiological systems most responsible for the altered functional performance associated with space flight.

  20. Improvement of burn pain management through routine pain monitoring and pain management protocol.

    PubMed

    Yang, Hyeong Tae; Hur, Giyeun; Kwak, In-Suk; Yim, Haejun; Cho, Yong Suk; Kim, Dohern; Hur, Jun; Kim, Jong Hyun; Lee, Boung Chul; Seo, Cheong Hoon; Chun, Wook

    2013-06-01

    Pain management is an important aspect of burn management. We developed a routine pain monitoring system and pain management protocol for burn patients. The purpose of this study is to evaluate the effectiveness of our new pain management system. From May 2011 to November 2011, the prospective study was performed with 107 burn patients. We performed control group (n=58) data analysis and then developed the pain management protocol and monitoring system. Next, we applied our protocol to patients and performed protocol group (n=49) data analysis, and compared this to control group data. Data analysis was performed using the Numeric Rating Scale (NRS) of background pain and procedural pain, Clinician-Administered PTSD Scale (CAPS), Hamilton Depression Rating Scale (HDRS), State-Trait Anxiety Inventory Scale (STAIS), and Holmes and Rahe Stress Scale (HRSS). The NRS of background pain for the protocol group was significantly decreased compared to the control group (2.8±2.0 versus 3.9±1.9), and the NRS of procedural pain of the protocol group was significantly decreased compared to the control group (4.8±2.8 versus 3.7±2.5). CAPS and HDRS were decreased in the protocol group, but did not have statistical significance. STAIS and HRSS were decreased in the protocol group, but only the STAIS had statistical significance. Our new pain management system was effective in burn pain management. However, adequate pain management can only be accomplished by a continuous and thorough effort. Therefore, pain control protocol and pain monitoring systems need to be under constant revision and improvement using creative ideas and approaches. Copyright © 2012 Elsevier Ltd and ISBI. All rights reserved.

  1. A protocol using coho salmon to monitor Tongass National Forest Land and Resource Management Plan standards and guidelines for fish habitat.

    Treesearch

    M.D. Bryant; Trent McDonald; R. Aho; B.E. Wright; Michelle Bourassa Stahl

    2008-01-01

    We describe a protocol to monitor the effectiveness of the Tongass Land Management Plan (TLMP) management standards for maintaining fish habitat. The protocol uses juvenile coho salmon (Oncorhynchus kisutch) in small tributary streams in forested watersheds. We used a 3-year pilot study to develop detailed methods to estimate juvenile salmonid...

  2. Supervised versus unsupervised technology-based levodopa monitoring in Parkinson's disease: an intrasubject comparison.

    PubMed

    Lopane, Giovanna; Mellone, Sabato; Corzani, Mattia; Chiari, Lorenzo; Cortelli, Pietro; Calandra-Buonaura, Giovanna; Contin, Manuela

    2018-06-01

    We aimed to assess the intrasubject reproducibility of a technology-based levodopa (LD) therapeutic monitoring protocol administered in supervised versus unsupervised conditions in patients with Parkinson's disease (PD). The study design was pilot, intrasubject, single center, open and prospective. Twenty patients were recruited. Patients performed a standardized monitoring protocol instrumented by an ad hoc embedded platform after their usual first morning LD dose in two different randomized ambulatory sessions: one under a physician's supervision, the other self-administered. The protocol is made up of serial motor and non-motor tests, including alternate finger tapping, Timed Up and Go test, and measurement of blood pressure. Primary motor outcomes included comparisons of intrasubject LD subacute motor response patterns over the 3-h test in the two experimental conditions. Secondary outcomes were the number of intrasession serial test repetitions due to technical or handling errors and patients' satisfaction with the unsupervised LD monitoring protocol. Intrasubject LD motor response patterns were concordant between the two study sessions in all patients but one. Platform handling problems averaged 4% of total planned serial tests for both sessions. Ninety-five percent of patients were satisfied with the self-administered LD monitoring protocol. To our knowledge, this study is the first to explore the potential of unsupervised technology-based objective motor and non-motor tasks to monitor subacute LD dosing effects in PD patients. The results are promising for future telemedicine applications.

  3. Single-cell time-lapse imaging of intracellular O2 in response to metabolic inhibition and mitochondrial cytochrome-c release

    PubMed Central

    Düssmann, Heiko; Perez-Alvarez, Sergio; Anilkumar, Ujval; Papkovsky, Dmitri B; Prehn, Jochen HM

    2017-01-01

    The detection of intracellular molecular oxygen (O2) levels is important for understanding cell physiology, cell death, and drug effects, and has recently been improved with the development of oxygen-sensitive probes that are compatible with live cell time-lapse microscopy. We here provide a protocol for the use of the nanoparticle probe MitoImage-MM2 to monitor intracellular oxygen levels by confocal microscopy under baseline conditions, in response to mitochondrial toxins, and following mitochondrial cytochrome-c release. We demonstrate that the MitoImage-MM2 probe, which embeds Pt(II)-5,10,15,20-tetrakis-(2,3,4,5,6–pentafluorophenyl)-porphyrin as oxygen sensor and poly(9,9-dioctylfluorene) as an O2-independent component, enables quantitative, ratiometric time-lapse imaging of intracellular O2. Multiplexing with tetra-methyl-rhodamine-methyl ester in HeLa cervical cancer cells showed significant increases in intracellular O2 accompanied by strong mitochondrial depolarization when respiratory chain complexes III or IV were inhibited by Antimycin A or sodium azide, respectively, and when cells were maintained at ‘physiological’ tissue O2 levels (5% O2). Multiplexing also allowed us to monitor intracellular O2 during the apoptotic signaling process of mitochondrial outer membrane permeabilization in HeLa expressing cytochrome-c-eGFP, and demonstrated that mitochondria post cytochrome-c release are able to retain their capacity to respire at physiological O2 despite a decrease in mitochondrial membrane potential. PMID:28569778

  4. Hormonal, metabolic and physiological effects of laparoscopic surgery using a detomidine-buprenorphine combination in standing horses.

    PubMed

    van Dijk, P; Lankveld, D P K; Rijkenhuizen, A B M; Jonker, F H

    2003-04-01

    To assess the hormonal, metabolic and physiological effects of laparascopic surgery performed under a sedative analgesic combination of detomidine and buprenorphine in standing horses. Prospective study. Eight healthy adult Dutch Warmblood horses and five healthy adult ponies undergoing laparoscopy were studied. Five healthy adult horses not undergoing laparoscopy were used as a control group. The sedative effect of an initial detomidine and buprenorphine injection was maintained using a continuous infusion of detomidine alone. The heart and respiratory rate, arterial blood pH and arterial oxygen and carbon dioxide tensions were monitored, while blood samples were taken for the measurement of glucose, lactate, cortisol, insulin and nonesterified fatty acids (NEFA). The same variables were monitored in a control group of horses which were sedated, but which did not undergo surgery. At the end of the sedation period the effects of detomidine were antagonized using atipamezole. The protocol provided suitable conditions for standing laparoscopy in horses. Laparoscopy induced obvious metabolic and endocrine responses which, with the exception of NEFA values, were not significantly different from changes found in the control group. While atipamezole did not produce detectable adverse effects, it is possible that anatagonism may not be essential. The technique described reliably produces adequate sedation and analgesia for laparoscopic procedures. The level of sedation/analgesia was controlled by decreasing or increasing the infusion rate. Antagonism of the effects of detomidine may not be necessary in all cases.

  5. 2018 EPA Protocol Gas Verification Program Participants

    EPA Pesticide Factsheets

    A list of participants for 2016 EPA's Protocol Gas Verification Program (PGVP) for stationary source monitoring. The list also has vendor IDs, which are production site-specific, and are the same ones used in the PGVP for ambient air monitoring.

  6. Current Status of EPA Protocol Gas Verification Program

    EPA Science Inventory

    Accurate compressed gas reference standards are needed to calibrate and audit continuous emission monitors (CEMs) and ambient air quality monitors that are being used for regulatory purposes. US Environmental Protection Agency (EPA) established its traceability protocol to ensur...

  7. An Internet of Things based physiological signal monitoring and receiving system for virtual enhanced health care network.

    PubMed

    Rajan, J Pandia; Rajan, S Edward

    2018-01-01

    Wireless physiological signal monitoring system designing with secured data communication in the health care system is an important and dynamic process. We propose a signal monitoring system using NI myRIO connected with the wireless body sensor network through multi-channel signal acquisition method. Based on the server side validation of the signal, the data connected to the local server is updated in the cloud. The Internet of Things (IoT) architecture is used to get the mobility and fast access of patient data to healthcare service providers. This research work proposes a novel architecture for wireless physiological signal monitoring system using ubiquitous healthcare services by virtual Internet of Things. We showed an improvement in method of access and real time dynamic monitoring of physiological signal of this remote monitoring system using virtual Internet of thing approach. This remote monitoring and access system is evaluated in conventional value. This proposed system is envisioned to modern smart health care system by high utility and user friendly in clinical applications. We claim that the proposed scheme significantly improves the accuracy of the remote monitoring system compared to the other wireless communication methods in clinical system.

  8. A review of protocols for monitoring streams and juvenile fish in forested regions of the Pacific Northwest.

    Treesearch

    Scott A. Stolnack; Mason D. Bryant; Robert C. Wissmar

    2005-01-01

    This document reviews existing and proposed protocols used to monitor stream ecosystem conditions and responses to land management activities in the Pacific Northwest. Because of recent work aimed at improving the utility of habitat survey and fish abundance assessment methods, this review focuses on current (since 1993) monitoring efforts that assess stream habitat...

  9. A habitat-based point-count protocol for terrestrial birds, emphasizing Washington and Oregon.

    Treesearch

    Mark H. Huff; Kelly A. Bettinger; Howard L. Ferguson; Martin J. Brown; Bob. Altman

    2000-01-01

    We describe a protocol and provide a summary for point-count monitoring of landbirds that is designed for habitat-based objectives. Presentation is in four steps: preparation and planning, selecting monitoring sites, establishing monitoring stations, and conducting point counts. We describe the basis for doing habitat-based point counts, how they are organized, and how...

  10. CURRENT STATUS OF THE EPA PROTOCOL GAS PROGRAM

    EPA Science Inventory

    Accurate compressed gas calibration standards are needed to calibrate continuous emission monitors (CEMs) and ambient air quality monitors that are being used for regulatory purposes. EPA has published a protocol to establish the traceability of these standards to national refer...

  11. Current Status of EPA Verification Program for EPA Protocol Gases

    EPA Science Inventory

    Accurate compressed gas calibration standards are needed to calibrate continuous emission monitors (CEMs) and ambient air quality monitors that are being used for regulatory purposes. US Environmental Protection Agency (EPA) established its traceability protocol to ensure that c...

  12. EPA Protocol Gas Verification Program - Presented at NIST Gas Panel Meeting

    EPA Science Inventory

    Accurate compressed gas calibration standards are needed to calibrate continuous emission monitors (CEMs) and ambient air quality monitors that are being used for regulatory purposes. US Environmental Protection Agency (EPA) established its traceability protocol to ensure that c...

  13. Draft Plan to Develop Non-Intrusive Load Monitoring Test Protocols

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mayhorn, Ebony T.; Sullivan, Greg P.; Petersen, Joseph M.

    2015-09-29

    This document presents a Draft Plan proposed to develop a common test protocol that can be used to evaluate the performance requirements of Non-Intrusive Load Monitoring. Development on the test protocol will be focused on providing a consistent method that can be used to quantify and compare the performance characteristics of NILM products. Elements of the protocols include specifications for appliances to be used, metrics, instrumentation, and a procedure to simulate appliance behavior during tests. In addition, three priority use cases for NILM will be identified and their performance requirements will specified.

  14. Preparation of Single-cohort Colonies and Hormone Treatment of Worker Honeybees to Analyze Physiology Associated with Role and/or Endocrine System.

    PubMed

    Ueno, Takayuki; Kawasaki, Kiyoshi; Kubo, Takeo

    2016-09-06

    Honeybee workers are engaged in various tasks related to maintaining colony activity. The tasks of the workers change according to their age (age-related division of labor). Young workers are engaged in nursing the brood (nurse bees), while older workers are engaged in foraging for nectar and pollen (foragers). The physiology of the workers changes in association with this role shift. For example, the main function of the hypopharyngeal glands (HPGs) changes from the secretion of major royal jelly proteins (MRJPs) to the secretion of carbohydrate-metabolizing enzymes. Because worker tasks change as the workers age in typical colonies, it is difficult to discriminate the physiological changes that occur with aging from those that occur with the role shift. To study the physiological changes in worker tissues, including the HPGs, in association with the role shift, it would be useful to manipulate the honeybee colony population by preparing single-cohort colonies in which workers of almost the same age perform different tasks. Here we describe a detailed protocol for preparing single-cohort colonies for this analysis. Six to eight days after single-cohort colony preparation, precocious foragers that perform foraging tasks earlier than usual appear in the colony. Representative results indicated role-associated changes in HPG gene expression, suggesting role-associated HPG function. In addition to manipulating the colony population, analysis of the endocrine system is important for investigating role-associated physiology. Here, we also describe a detailed protocol for treating workers with 20-hydroxyecdysone (20E), an active form of ecdysone, and methoprene, a juvenile hormone analogue. The survival rate of treated bees was sufficient to examine gene expression in the HPGs. Gene expression changes were observed in response to 20E- and/or methoprene-treatment, suggesting that hormone treatments induce physiological changes of the HPGs. The protocol for hormone treatment described here is appropriate for examining hormonal effects on worker physiology.

  15. A Collaborative Protocol for Encopresis Management in School-Aged Children.

    ERIC Educational Resources Information Center

    Chaney, Carol A.

    1995-01-01

    Encopresis affects a small percentage of children, but most parents are unaware of the condition and react punitively. The lengthy, complex management program usually includes physiological and behavioral approaches. The collaborative management protocol focuses on medical clinicians, families, children, school nurses, and teachers, and can help…

  16. Robowell: An automated process for monitoring ground water quality using established sampling protocols

    USGS Publications Warehouse

    Granato, G.E.; Smith, K.P.

    1999-01-01

    Robowell is an automated process for monitoring selected ground water quality properties and constituents by pumping a well or multilevel sampler. Robowell was developed and tested to provide a cost-effective monitoring system that meets protocols expected for manual sampling. The process uses commercially available electronics, instrumentation, and hardware, so it can be configured to monitor ground water quality using the equipment, purge protocol, and monitoring well design most appropriate for the monitoring site and the contaminants of interest. A Robowell prototype was installed on a sewage treatment plant infiltration bed that overlies a well-studied unconfined sand and gravel aquifer at the Massachusetts Military Reservation, Cape Cod, Massachusetts, during a time when two distinct plumes of constituents were released. The prototype was operated from May 10 to November 13, 1996, and quality-assurance/quality-control measurements demonstrated that the data obtained by the automated method was equivalent to data obtained by manual sampling methods using the same sampling protocols. Water level, specific conductance, pH, water temperature, dissolved oxygen, and dissolved ammonium were monitored by the prototype as the wells were purged according to U.S Geological Survey (USGS) ground water sampling protocols. Remote access to the data record, via phone modem communications, indicated the arrival of each plume over a few days and the subsequent geochemical reactions over the following weeks. Real-time availability of the monitoring record provided the information needed to initiate manual sampling efforts in response to changes in measured ground water quality, which proved the method and characterized the screened portion of the plume in detail through time. The methods and the case study described are presented to document the process for future use.

  17. Forest bird monitoring protocol for strategic habitat conservation and endangered species management on O'ahu Forest National Wildlife Refuge, Island of O'ahu, Hawai'i

    USGS Publications Warehouse

    Camp, Richard J.; Gorresen, P. Marcos; Banko, Paul C.

    2011-01-01

    This report describes the results of a pilot forest bird survey and a consequent forest bird monitoring protocol that was developed for the O'ahu Forest National Wildlife Refuge, O'ahu Island, Hawai'i. The pilot survey was conducted to inform aspects of the monitoring protocol and to provide a baseline with which to compare future surveys on the Refuge. The protocol was developed in an adaptive management framework to track bird distribution and abundance and to meet the strategic habitat conservation requirements of the Refuge. Funding for this research was provided through a Science Support Partnership grant sponsored jointly by the U.S. Geological Survey (USGS) and the U.S. Fish and Wildlife Service (USFWS).

  18. TH-E-209-00: Radiation Dose Monitoring and Protocol Management

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    Radiation dose monitoring solutions have opened up new opportunities for medical physicists to be more involved in modern clinical radiology practices. In particular, with the help of comprehensive radiation dose data, data-driven protocol management and informed case follow up are now feasible. Significant challenges remain however and the problems faced by medical physicists are highly heterogeneous. Imaging systems from multiple vendors and a wide range of vintages co-exist in the same department and employ data communication protocols that are not fully standardized or implemented making harmonization complex. Many different solutions for radiation dose monitoring have been implemented by imaging facilitiesmore » over the past few years. Such systems are based on commercial software, home-grown IT solutions, manual PACS data dumping, etc., and diverse pathways can be used to bring the data to impact clinical practice. The speakers will share their experiences with creating or tailoring radiation dose monitoring/management systems and procedures over the past few years, which vary significantly in design and scope. Topics to cover: (1) fluoroscopic dose monitoring and high radiation event handling from a large academic hospital; (2) dose monitoring and protocol optimization in pediatric radiology; and (3) development of a home-grown IT solution and dose data analysis framework. Learning Objectives: Describe the scope and range of radiation dose monitoring and protocol management in a modern radiology practice Review examples of data available from a variety of systems and how it managed and conveyed. Reflect on the role of the physicist in radiation dose awareness.« less

  19. TH-E-209-02: Dose Monitoring and Protocol Optimization: The Pediatric Perspective

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    MacDougall, R.

    Radiation dose monitoring solutions have opened up new opportunities for medical physicists to be more involved in modern clinical radiology practices. In particular, with the help of comprehensive radiation dose data, data-driven protocol management and informed case follow up are now feasible. Significant challenges remain however and the problems faced by medical physicists are highly heterogeneous. Imaging systems from multiple vendors and a wide range of vintages co-exist in the same department and employ data communication protocols that are not fully standardized or implemented making harmonization complex. Many different solutions for radiation dose monitoring have been implemented by imaging facilitiesmore » over the past few years. Such systems are based on commercial software, home-grown IT solutions, manual PACS data dumping, etc., and diverse pathways can be used to bring the data to impact clinical practice. The speakers will share their experiences with creating or tailoring radiation dose monitoring/management systems and procedures over the past few years, which vary significantly in design and scope. Topics to cover: (1) fluoroscopic dose monitoring and high radiation event handling from a large academic hospital; (2) dose monitoring and protocol optimization in pediatric radiology; and (3) development of a home-grown IT solution and dose data analysis framework. Learning Objectives: Describe the scope and range of radiation dose monitoring and protocol management in a modern radiology practice Review examples of data available from a variety of systems and how it managed and conveyed. Reflect on the role of the physicist in radiation dose awareness.« less

  20. Simultaneous validation of the Grandway MD2301 digital automatic blood pressure monitor by the British Hypertension Society and the Association for the Advancement of Medical Instrumentation/the International Organization for Standardization protocols.

    PubMed

    Huang, Jinhua; Wang, Yun; Liu, Zhaoying; Wang, Yuling

    2017-02-01

    The aim of this study was to determine the accuracy of the Grandway MD2301 digital automatic blood pressure monitor by the British Hypertension Society (BHS) and the Association for the Advancement of Medical Instrumentation (AAMI)/the International Organization for Standardization (ISO) protocols. A total of 85 participants were included for evaluation based on the requirements of the BHS and the AAMI/ISO protocols. The validation procedure and data analysis followed the protocols precisely. The device achieved A/A grading for the BHS protocol and maintained A/A grading throughout the low, medium and high blood pressure ranges. The device also fulfilled the requirement of the AAMI/ISO protocol with device-observer differences of -0.9±5.6 and 0.8±5.2 mmHg for systolic and diastolic blood pressure, respectively, for criterion 1, and -0.9±4.7 and 0.8±4.2 mmHg, respectively, for criterion 2. The Grandway MD2301 digital automatic blood pressure monitor achieved A/A grade of the BHS protocol and passed the requirements of the AAMI/ISO protocol in adults.

  1. Nursing stress and patient care: real-time investigation of the effect of nursing tasks and demands on psychological stress, physiological stress, and job performance: study protocol.

    PubMed

    Farquharson, Barbara; Bell, Cheryl; Johnston, Derek; Jones, Martyn; Schofield, Pat; Allan, Julia; Ricketts, Ian; Morrison, Kenny; Johnston, Marie

    2013-10-01

    To examine the effects of nursing tasks (including their physiological and psychological demands, and the moderating effects of reward and control) on distress and job performance in real time. Nurses working in hospital settings report high levels of occupational stress. Stress in nurses has been linked to reduced physical and psychological health, reduced job satisfaction, increased sickness absence, increased staff turnover, and poorer job performance. In this study, we will investigate theoretical models of stress and use multiple methods, including real-time data collection, to assess the relationship between stress and different nursing tasks in general medical and surgical ward nurses. A real-time, repeated measures design. During 2011/2012, 100 nurses from a large general teaching hospital in Scotland will: (a) complete self-reports of mood; (b) have their heart rate and activity monitored over two shifts to obtain physiological indices of stress and energy expenditure; (c) provide perceptions of the determinants of stress in complex ward environments; and (d) describe their main activities. All measures will be taken repeatedly in real time over two working shifts. Data obtained in this study will be analysed to examine the relationships between nursing tasks, self-reported and physiological measures of stress and to assess the effect of occupational stress on multiple work outcomes. The results will inform theoretical understanding of nurse stress and its determinants and suggest possible targets for intervention to reduce stress and associated harmful consequences. © 2013 Blackwell Publishing Ltd.

  2. Physiological Reactivity, Social Support, and Memory in Early Childhood

    ERIC Educational Resources Information Center

    Quas, Jodi A.; Bauer, Amy; Boyce, W. Thomas

    2004-01-01

    The interactive effects of physiological reactivity and social support on children's memory were examined. Four- to 6-year-olds completed a laboratory protocol during which autonomic responses and salivary cortisol were measured. Memory was assessed shortly afterward and 2 weeks later. During the second interview, children were questioned by a…

  3. Smartphone-Based Monitoring of Objective and Subjective Data in Affective Disorders: Where Are We and Where Are We Going? Systematic Review

    PubMed Central

    Dogan, Ezgi; Wagner, Xenija; Hegerl, Ulrich; Kohls, Elisabeth

    2017-01-01

    Background Electronic mental health interventions for mood disorders have increased rapidly over the past decade, most recently in the form of various systems and apps that are delivered via smartphones. Objective We aim to provide an overview of studies on smartphone-based systems that combine subjective ratings with objectively measured data for longitudinal monitoring of patients with affective disorders. Specifically, we aim to examine current knowledge on: (1) the feasibility of, and adherence to, such systems; (2) the association of monitored data with mood status; and (3) the effects of monitoring on clinical outcomes. Methods We systematically searched PubMed, Web of Science, PsycINFO, and the Cochrane Central Register of Controlled Trials for relevant articles published in the last ten years (2007-2017) by applying Boolean search operators with an iterative combination of search terms, which was conducted in February 2017. Additional articles were identified via pearling, author correspondence, selected reference lists, and trial protocols. Results A total of 3463 unique records were identified. Twenty-nine studies met the inclusion criteria and were included in the review. The majority of articles represented feasibility studies (n=27); two articles reported results from one randomized controlled trial (RCT). In total, six different self-monitoring systems for affective disorders that used subjective mood ratings and objective measurements were included. These objective parameters included physiological data (heart rate variability), behavioral data (phone usage, physical activity, voice features), and context/environmental information (light exposure and location). The included articles contained results regarding feasibility of such systems in affective disorders, showed reasonable accuracy in predicting mood status and mood fluctuations based on the objectively monitored data, and reported observations about the impact of monitoring on clinical state and adherence of patients to the system usage. Conclusions The included observational studies and RCT substantiate the value of smartphone-based approaches for gathering long-term objective data (aside from self-ratings to monitor clinical symptoms) to predict changes in clinical states, and to investigate causal inferences about state changes in patients with affective disorders. Although promising, a much larger evidence-base is necessary to fully assess the potential and the risks of these approaches. Methodological limitations of the available studies (eg, small sample sizes, variations in the number of observations or monitoring duration, lack of RCT, and heterogeneity of methods) restrict the interpretability of the results. However, a number of study protocols stated ambitions to expand and intensify research in this emerging and promising field. PMID:28739561

  4. Mutual-Information-Based Incremental Relaying Communications for Wireless Biomedical Implant Systems

    PubMed Central

    Liao, Yangzhe; Cai, Qing; Ai, Qingsong; Liu, Quan

    2018-01-01

    Network lifetime maximization of wireless biomedical implant systems is one of the major research challenges of wireless body area networks (WBANs). In this paper, a mutual information (MI)-based incremental relaying communication protocol is presented where several on-body relay nodes and one coordinator are attached to the clothes of a patient. Firstly, a comprehensive analysis of a system model is investigated in terms of channel path loss, energy consumption, and the outage probability from the network perspective. Secondly, only when the MI value becomes smaller than the predetermined threshold is data transmission allowed. The communication path selection can be either from the implanted sensor to the on-body relay then forwards to the coordinator or from the implanted sensor to the coordinator directly, depending on the communication distance. Moreover, mathematical models of quality of service (QoS) metrics are derived along with the related subjective functions. The results show that the MI-based incremental relaying technique achieves better performance in comparison to our previous proposed protocol techniques regarding several selected performance metrics. The outcome of this paper can be applied to intra-body continuous physiological signal monitoring, artificial biofeedback-oriented WBANs, and telemedicine system design. PMID:29419784

  5. Mutual-Information-Based Incremental Relaying Communications for Wireless Biomedical Implant Systems.

    PubMed

    Liao, Yangzhe; Leeson, Mark S; Cai, Qing; Ai, Qingsong; Liu, Quan

    2018-02-08

    Network lifetime maximization of wireless biomedical implant systems is one of the major research challenges of wireless body area networks (WBANs). In this paper, a mutual information (MI)-based incremental relaying communication protocol is presented where several on-body relay nodes and one coordinator are attached to the clothes of a patient. Firstly, a comprehensive analysis of a system model is investigated in terms of channel path loss, energy consumption, and the outage probability from the network perspective. Secondly, only when the MI value becomes smaller than the predetermined threshold is data transmission allowed. The communication path selection can be either from the implanted sensor to the on-body relay then forwards to the coordinator or from the implanted sensor to the coordinator directly, depending on the communication distance. Moreover, mathematical models of quality of service (QoS) metrics are derived along with the related subjective functions. The results show that the MI-based incremental relaying technique achieves better performance in comparison to our previous proposed protocol techniques regarding several selected performance metrics. The outcome of this paper can be applied to intra-body continuous physiological signal monitoring, artificial biofeedback-oriented WBANs, and telemedicine system design.

  6. Locomotor, cardiocirculatory and metabolic adaptations to training in Andalusian and Anglo-Arabian horses.

    PubMed

    Muñoz, A; Santisteban, R; Rubio, M D; Agüera, E I; Escribano, B M; Castejón, F M

    1999-02-01

    The effects of two training programmes in 20 Andalusian and 12 Anglo-Arabian horses were evaluated by an increasing intensity work test at velocities of 4, 5, 6, 7 and 8 m sec(-1). Heart rate was monitored and blood samples were drawn at rest and after each velocity to analyse packed cell volume, haemoglobin concentration, plasma lactate and potassium levels. Furthermore, the programmes were video-taped and stride length, duration and frequency, stance (restraint and propulsion), swing phase durations and stride vertical component were measured. The training protocol of the Andalusian horses produced significant decreases in the cardiovascular, haematological and metabolic responses to exercise. Locomotory training adaptation consisted of an increased stride frequency and a reduced stride length and vertical stride component. The last variable was the limiting factor of stride length both before and after training in the Andalusian horses. A different training protocol for show-jumping competition in Anglo-Arabian horses failed to show significant differences in the studied parameters to the work test, although an increase in stride length at velocities of over 6 m sec(-1) was observed. Stride vertical component did not have an effect on the physiological response to exercise, either before or after training.

  7. Mercury Assessment and Monitoring Protocol for the Bear Creek Watershed, Colusa County, California

    USGS Publications Warehouse

    Suchanek, Thomas H.; Hothem, Roger L.; Rytuba, James J.; Yee, Julie L.

    2010-01-01

    This report summarizes the known information on the occurrence and distribution of mercury (Hg) in physical/chemical and biological matrices within the Bear Creek watershed. Based on these data, a matrix-specific monitoring protocol for the evaluation of the effectiveness of activities designed to remediate Hg contamination in the Bear Creek watershed is presented. The monitoring protocol documents procedures for collecting and processing water, sediment, and biota for estimation of total Hg (TotHg) and monomethyl mercury (MMeHg) in the Bear Creek watershed. The concurrent sampling of TotHg and MMeHg in biota as well as water and sediment from 10 monitoring sites is designed to assess the relative bioavailability of Hg released from Hg sources in the watershed and identify environments conducive to Hg methylation. These protocols are designed to assist landowners, land managers, water quality regulators, and scientists in determining whether specific restoration/mitigation actions lead to significant progress toward achieving water quality goals to reduce Hg in Bear and Sulphur Creeks.

  8. Indicators and protocols for monitoring impacts of formal and informal trails in protected areas

    USGS Publications Warehouse

    Marion, Jeffrey L.; Leung, Yu-Fai

    2011-01-01

    Trails are a common recreation infrastructure in protected areas and their conditions affect the quality of natural resources and visitor experiences. Various trail impact indicators and assessment protocols have been developed in support of monitoring programs, which are often used for management decision-making or as part of visitor capacity management frameworks. This paper reviews common indicators and assessment protocols for three types of trails, surfaced formal trails, unsurfaced formal trails, and informal (visitor-created) trails. Monitoring methods and selected data from three U.S. National Park Service units are presented to illustrate some common trail impact indicators and assessment options.

  9. Remote Sensing and the Kyoto Protocol: A Review of Available and Future Technology for Monitoring Treaty Compliance

    NASA Technical Reports Server (NTRS)

    Imhoff, Marc L.; Rosenquist, A.; Milne, A. K.; Dobson, M. C.; Qi, J.

    2000-01-01

    An International workshop was held to address how remote sensing technology could be used to support the environmental monitoring requirements of the Kyoto Protocol. An overview of the issues addressed and the findings of the workshop are discussed.

  10. Lightweight UDP Pervasive Protocol in Smart Home Environment Based on Labview

    NASA Astrophysics Data System (ADS)

    Kurniawan, Wijaya; Hannats Hanafi Ichsan, Mochammad; Rizqika Akbar, Sabriansyah; Arwani, Issa

    2017-04-01

    TCP (Transmission Control Protocol) technology in a reliable environment was not a problem, but not in an environment where the entire Smart Home network connected locally. Currently employing pervasive protocols using TCP technology, when data transmission is sent, it would be slower because they have to perform handshaking process in advance and could not broadcast the data. On smart home environment, it does not need large size and complex data transmission between monitoring site and monitoring center required in Smart home strain monitoring system. UDP (User Datagram Protocol) technology is quick and simple on data transmission process. UDP can broadcast messages because the UDP did not require handshaking and with more efficient memory usage. LabVIEW is a programming language software for processing and visualization of data in the field of data acquisition. This paper proposes to examine Pervasive UDP protocol implementations in smart home environment based on LabVIEW. UDP coded in LabVIEW and experiments were performed on a PC and can work properly.

  11. Assessing interactions among multiple physiological systems during walking outside a laboratory: An Android based gait monitor

    PubMed Central

    Sejdić, E.; Millecamps, A.; Teoli, J.; Rothfuss, M. A.; Franconi, N. G.; Perera, S.; Jones, A. K.; Brach, J. S.; Mickle, M. H.

    2015-01-01

    Gait function is traditionally assessed using well-lit, unobstructed walkways with minimal distractions. In patients with subclinical physiological abnormalities, these conditions may not provide enough stress on their ability to adapt to walking. The introduction of challenging walking conditions in gait can induce responses in physiological systems in addition to the locomotor system. There is a need for a device that is capable of monitoring multiple physiological systems in various walking conditions. To address this need, an Android-based gait-monitoring device was developed that enabled the recording of a patient's physiological systems during walking. The gait-monitoring device was tested during self-regulated overground walking sessions of fifteen healthy subjects that included 6 females and 9 males aged 18 to 35 years. The gait-monitoring device measures the patient's stride interval, acceleration, electrocardiogram, skin conductance and respiratory rate. The data is stored on an Android phone and is analyzed offline through the extraction of features in the time, frequency and time-frequency domains. The analysis of the data depicted multisystem physiological interactions during overground walking in healthy subjects. These interactions included locomotion-electrodermal, locomotion-respiratory and cardiolocomotion couplings. The current results depicting strong interactions between the locomotion system and the other considered systems (i.e., electrodermal, respiratory and cardivascular systems) warrant further investigation into multisystem interactions during walking, particularly in challenging walking conditions with older adults. PMID:26390946

  12. Motion-compensated noncontact imaging photoplethysmography to monitor cardiorespiratory status during exercise

    NASA Astrophysics Data System (ADS)

    Sun, Yu; Hu, Sijung; Azorin-Peris, Vicente; Greenwald, Stephen; Chambers, Jonathon; Zhu, Yisheng

    2011-07-01

    With the advance of computer and photonics technology, imaging photoplethysmography [(PPG), iPPG] can provide comfortable and comprehensive assessment over a wide range of anatomical locations. However, motion artifact is a major drawback in current iPPG systems, particularly in the context of clinical assessment. To overcome this issue, a new artifact-reduction method consisting of planar motion compensation and blind source separation is introduced in this study. The performance of the iPPG system was evaluated through the measurement of cardiac pulse in the hand from 12 subjects before and after 5 min of cycling exercise. Also, a 12-min continuous recording protocol consisting of repeated exercises was taken from a single volunteer. The physiological parameters (i.e., heart rate, respiration rate), derived from the images captured by the iPPG system, exhibit functional characteristics comparable to conventional contact PPG sensors. Continuous recordings from the iPPG system reveal that heart and respiration rates can be successfully tracked with the artifact reduction method even in high-intensity physical exercise situations. The outcome from this study thereby leads to a new avenue for noncontact sensing of vital signs and remote physiological assessment, with clear applications in triage and sports training.

  13. Use of portable blood physiology point-of-care devices for basic and applied research on vertebrates: a review

    PubMed Central

    Stoot, Lauren J.; Cairns, Nicholas A.; Cull, Felicia; Taylor, Jessica J.; Jeffrey, Jennifer D.; Morin, Félix; Mandelman, John W.; Clark, Timothy D.; Cooke, Steven J.

    2014-01-01

    Non-human vertebrate blood is commonly collected and assayed for a variety of applications, including veterinary diagnostics and physiological research. Small, often non-lethal samples enable the assessment and monitoring of the physiological state and health of the individual. Traditionally, studies that rely on blood physiology have focused on captive animals or, in studies conducted in remote settings, have required the preservation and transport of samples for later analysis. In either situation, large, laboratory-bound equipment and traditional assays and analytical protocols are required. The use of point-of-care (POC) devices to measure various secondary blood physiological parameters, such as metabolites, blood gases and ions, has become increasingly popular recently, due to immediate results and their portability, which allows the freedom to study organisms in the wild. Here, we review the current uses of POC devices and their applicability to basic and applied studies on a variety of non-domesticated species. We located 79 individual studies that focused on non-domesticated vertebrates, including validation and application of POC tools. Studies focused on a wide spectrum of taxa, including mammals, birds and herptiles, although the majority of studies focused on fish, and typical variables measured included blood glucose, lactate and pH. We found that calibrations for species-specific blood physiology values are necessary, because ranges can vary within and among taxa and are sometimes outside the measurable range of the devices. In addition, although POC devices are portable and robust, most require durable cases, they are seldom waterproof/water-resistant, and factors such as humidity and temperature can affect the performance of the device. Overall, most studies concluded that POC devices are suitable alternatives to traditional laboratory devices and eliminate the need for transport of samples; however, there is a need for greater emphasis on rigorous calibration and validation of these units and appreciation of their limitations. PMID:27293632

  14. Improving metabolic monitoring in patients maintained on antipsychotics in Penang, Malaysia.

    PubMed

    Hor, Esther Sl; Subramaniam, Sivasangari; Koay, Jun Min; Bharathy, Arokiamary; Vasudevan, Umadevi; Panickulam, Joseph J; Ng, InnTiong; Arif, Nor Hayati; Russell, Vincent

    2016-02-01

    To evaluate the monitoring of metabolic parameters among outpatients maintained on antipsychotic medications in a general hospital setting in Malaysia and to assess the impact of a local monitoring protocol. By performing a baseline audit of files from a random sample of 300 patients prescribed antipsychotic medications for at least 1 year; we determined the frequency of metabolic monitoring. The findings informed the design of a new local protocol, on which clinical staff was briefed. We re-evaluated metabolic monitoring immediately after implementation, in a small sample of new referrals and current patients. We explored staff perceptions of the initiative with a follow-up focus group, 6 months post-implementation. The baseline audit revealed a sub-optimal frequency of metabolic parameter recording. Re-audit, following implementation of the new protocol, revealed improved monitoring but persisting deficits. Dialogue with the clinical staff led to further protocol modification, clearer definition of staff roles and use of a standard recording template. Focus group findings revealed positive perceptions of the initiative, but persisting implementation barriers, including cultural issues surrounding waist circumference measurement. Responding to challenges in achieving improved routine metabolic monitoring of patients maintained on antipsychotics required on-going dialogue with the clinical staff, in order to address both service pressures and cultural concerns. © The Royal Australian and New Zealand College of Psychiatrists 2015.

  15. Protocol for culturing low density pure rat hippocampal neurons supported by mature mixed neuron cultures.

    PubMed

    Yang, Qian; Ke, Yini; Luo, Jianhong; Tang, Yang

    2017-02-01

    primary hippocampal neuron cultures allow for subcellular morphological dissection, easy access to drug treatment and electrophysiology analysis of individual neurons, and is therefore an ideal model for the study of neuron physiology. While neuron and glia mixed cultures are relatively easy to prepare, pure neurons are particular hard to culture at low densities which are suitable for morphology studies. This may be due to a lack of neurotrophic factors such as brain derived neurotrophic factor (BDNF), neurotrophin-3 (NT3) and Glial cell line-derived neurotrophic factor (GDNF). In this study we used a two step protocol in which neuron-glia mixed cultures were initially prepared for maturation to support the growth of young neurons plated at very low densities. Our protocol showed that neurotrophic support resulted in physiologically functional hippocampal neurons with larger cell body, increased neurite length and decreased branching and complexity compared to cultures prepared using a conventional method. Our protocol provides a novel way to culture highly uniformed hippocampal neurons for acquiring high quality, neuron based data. Copyright © 2016 Elsevier B.V. All rights reserved.

  16. Genetic manipulation and monitoring of autophagy in Drosophila.

    PubMed

    Neufeld, Thomas P

    2008-01-01

    Drosophila melanogaster provides a model system useful for many aspects of the study of autophagy in vivo. These include testing and validation of genes potentially involved in autophagy, discovery of novel genes through genetic screening for mutations that affect autophagy, and analysis of potential roles of autophagy in specific developmental or physiological processes. In recent years, a number of techniques and transgenic and mutant fly strains have been developed to facilitate autophagy analysis in this system. Here, protocols are described for activating or inhibiting autophagy in Drosophila, and for examining the progression of autophagy in vivo through imaging-based assays. The goal of this chapter is to provide a resource both for autophagy investigators with limited familiarity with fly genetics, as well as for experienced Drosophila biologists who wish to test for connections between autophagy and a given gene, pathway or process.

  17. LC3- and p62-based biochemical methods for the analysis of autophagy progression in mammalian cells.

    PubMed

    Jiang, Peidu; Mizushima, Noboru

    2015-03-01

    Autophagy is an intracellular degradation system that delivers cytoplasmic materials to the lysosome or vacuole. This system plays a crucial role in various physiological and pathological processes in living organisms ranging from yeast to mammals. Thus, an accurate and reliable measure of autophagic activity is necessary. However, autophagy involves dynamic and complicated processes that make it difficult to analyze. The term "autophagic flux" is used to denote overall autophagic degradation (i.e., delivery of autophagic cargo to the lysosome) rather than autophagosome formation. Immunoblot analysis of LC3 and p62/SQSTM1, among other proteins, has been widely used to monitor autophagic flux. Here, we describe basic protocols to measure the levels of endogenous LC3 and p62 by immunoblotting in cultured mammalian cells. Copyright © 2014 Elsevier Inc. All rights reserved.

  18. A cooled CCD camera-based protocol provides an effective solution for in vitro monitoring of luciferase.

    PubMed

    Afshari, Amirali; Uhde-Stone, Claudia; Lu, Biao

    2015-03-13

    Luciferase assay has become an increasingly important technique to monitor a wide range of biological processes. However, the mainstay protocols require a luminometer to acquire and process the data, therefore limiting its application to specialized research labs. To overcome this limitation, we have developed an alternative protocol that utilizes a commonly available cooled charge-coupled device (CCCD), instead of a luminometer for data acquiring and processing. By measuring activities of different luciferases, we characterized their substrate specificity, assay linearity, signal-to-noise levels, and fold-changes via CCCD. Next, we defined the assay parameters that are critical for appropriate use of CCCD for different luciferases. To demonstrate the usefulness in cultured mammalian cells, we conducted a case study to examine NFκB gene activation in response to inflammatory signals in human embryonic kidney cells (HEK293 cells). We found that data collected by CCCD camera was equivalent to those acquired by luminometer, thus validating the assay protocol. In comparison, The CCCD-based protocol is readily amenable to live-cell and high-throughput applications, offering fast simultaneous data acquisition and visual and quantitative data presentation. In conclusion, the CCCD-based protocol provides a useful alternative for monitoring luciferase reporters. The wide availability of CCCD will enable more researchers to use luciferases to monitor and quantify biological processes. Copyright © 2015 Elsevier Inc. All rights reserved.

  19. Estuarine water quality in parks of the Northeast Coastal and Barrier Network: Development and early implementation of vital signs estuarine nutrient-enrichment monitoring, 2003-06

    USGS Publications Warehouse

    Kopp, Blaine S.; Nielsen, Martha; Glisic, Dejan; Neckles, Hilary A.

    2009-01-01

    This report documents results of pilot tests of a protocol for monitoring estuarine nutrient enrichment for the Vital Signs Monitoring Program of the National Park Service Northeast Coastal and Barrier Network. Data collected from four parks during protocol development in 2003-06 are presented: Gateway National Recreation Area, Colonial National Historic Park, Fire Island National Seashore, and Assateague Island National Seashore. The monitoring approach incorporates several spatial and temporal designs to address questions at a hierarchy of scales. Indicators of estuarine response to nutrient enrichment were sampled using a probability design within park estuaries during a late-summer index period. Monitoring variables consisted of dissolved-oxygen concentration, chlorophyll a concentration, water temperature, salinity, attenuation of downwelling photosynthetically available radiation (PAR), and turbidity. The statistical sampling design allowed the condition of unsampled locations to be inferred from the distribution of data from a set of randomly positioned "probability" stations. A subset of sampling stations was sampled repeatedly during the index period, and stations were not rerandomized in subsequent years. These "trend stations" allowed us to examine temporal variability within the index period, and to improve the sensitivity of the monitoring protocol to detecting change through time. Additionally, one index site in each park was equipped for continuous monitoring throughout the index period. Thus, the protocol includes elements of probabilistic and targeted spatial sampling, and the temporal intensity ranges from snapshot assessments to continuous monitoring.

  20. Building Capacity for a Long-Term, in-Situ, National-Scale Phenology Monitoring Network: Successes, Challenges and Lessons Learned

    NASA Astrophysics Data System (ADS)

    Weltzin, J. F.; Browning, D. M.

    2014-12-01

    The USA National Phenology Network (USA-NPN; www.usanpn.org) is a national-scale science and monitoring initiative focused on phenology - the study of seasonal life-cycle events such as leafing, flowering, reproduction, and migration - as a tool to understand the response of biodiversity to environmental variation and change. USA-NPN provides a hierarchical, national monitoring framework that enables other organizations to leverage the capacity of the Network for their own applications - minimizing investment and duplication of effort - while promoting interoperability. Network participants can leverage: (1) Standardized monitoring protocols that have been broadly vetted, tested and published; (2) A centralized National Phenology Database (NPDb) for maintaining, archiving and replicating data, with standard metadata, terms-of-use, web-services, and documentation of QA/QC, plus tools for discovery, visualization and download of raw data and derived data products; and/or (3) A national in-situ, multi-taxa phenological monitoring system, Nature's Notebook, which enables participants to observe and record phenology of plants and animals - based on the protocols and information management system (IMS) described above - via either web or mobile applications. The protocols, NPDb and IMS, and Nature's Notebook represent a hierarchy of opportunities for involvement by a broad range of interested stakeholders, from individuals to agencies. For example, some organizations have adopted (e.g., the National Ecological Observatory Network or NEON) -- or are considering adopting (e.g., the Long-Term Agroecosystems Network or LTAR) -- the USA-NPN standardized protocols, but will develop their own database and IMS with web services to promote sharing of data with the NPDb. Other organizations (e.g., the Inventory and Monitoring Programs of the National Wildlife Refuge System and the National Park Service) have elected to use Nature's Notebook to support their phenological monitoring programs. We highlight the challenges and benefits of integrating phenology monitoring within existing and emerging national monitoring networks, and showcase opportunities that exist when standardized protocols are adopted and implemented to promote data interoperability and sharing.

  1. A guide to processing bat acoustic data for the North American Bat Monitoring Program (NABat)

    USGS Publications Warehouse

    Reichert, Brian; Lausen, Cori; Loeb, Susan; Weller, Ted; Allen, Ryan; Britzke, Eric; Hohoff, Tara; Siemers, Jeremy; Burkholder, Braden; Herzog, Carl; Verant, Michelle

    2018-06-14

    The North American Bat Monitoring Program (NABat) aims to improve the state of conservation science for all species of bats shared by the United States, Canada, and Mexico. To accomplish this goal, NABat offers guidance and standardized protocols for acoustic monitoring of bats. In this document, “A Guide to Processing Bat Acoustic Data for the North American Bat Monitoring Program (NABat),” we provide general recommendations and specific workflows for the process of identifying bat species from acoustic files recorded using the NABat stationary point and mobile transect acoustic monitoring protocols.

  2. The Lactate Minimum Test: Concept, Methodological Aspects and Insights for Future Investigations in Human and Animal Models

    PubMed Central

    Messias, Leonardo H. D.; Gobatto, Claudio A.; Beck, Wladimir R.; Manchado-Gobatto, Fúlvia B.

    2017-01-01

    In 1993, Uwe Tegtbur proposed a useful physiological protocol named the lactate minimum test (LMT). This test consists of three distinct phases. Firstly, subjects must perform high intensity efforts to induce hyperlactatemia (phase 1). Subsequently, 8 min of recovery are allowed for transposition of lactate from myocytes (for instance) to the bloodstream (phase 2). Right after the recovery, subjects are submitted to an incremental test until exhaustion (phase 3). The blood lactate concentration is expected to fall during the first stages of the incremental test and as the intensity increases in subsequent stages, to rise again forming a “U” shaped blood lactate kinetic. The minimum point of this curve, named the lactate minimum intensity (LMI), provides an estimation of the intensity that represents the balance between the appearance and clearance of arterial blood lactate, known as the maximal lactate steady state intensity (iMLSS). Furthermore, in addition to the iMLSS estimation, studies have also determined anaerobic parameters (e.g., peak, mean, and minimum force/power) during phase 1 and also the maximum oxygen consumption in phase 3; therefore, the LMT is considered a robust physiological protocol. Although, encouraging reports have been published in both human and animal models, there are still some controversies regarding three main factors: (1) the influence of methodological aspects on the LMT parameters; (2) LMT effectiveness for monitoring training effects; and (3) the LMI as a valid iMLSS estimator. Therefore, the aim of this review is to provide a balanced discussion between scientific evidence of the aforementioned issues, and insights for future investigations are suggested. In summary, further analyses is necessary to determine whether these factors are worthy, since the LMT is relevant in several contexts of health sciences. PMID:28642717

  3. Metaplasticity in human primary somatosensory cortex: effects on physiology and tactile perception.

    PubMed

    Jones, Christina B; Lulic, Tea; Bailey, Aaron Z; Mackenzie, Tanner N; Mi, Yi Qun; Tommerdahl, Mark; Nelson, Aimee J

    2016-05-01

    Theta-burst stimulation (TBS) over human primary motor cortex evokes plasticity and metaplasticity, the latter contributing to the homeostatic balance of excitation and inhibition. Our knowledge of TBS-induced effects on primary somatosensory cortex (SI) is limited, and it is unknown whether TBS induces metaplasticity within human SI. Sixteen right-handed participants (6 females, mean age 23 yr) received two TBS protocols [continuous TBS (cTBS) and intermittent TBS (iTBS)] delivered in six different combinations over SI in separate sessions. TBS protocols were delivered at 30 Hz and were as follows: a single cTBS protocol, a single iTBS protocol, cTBS followed by cTBS, iTBS followed by iTBS, cTBS followed by iTBS, and iTBS followed by cTBS. Measures included the amplitudes of the first and second somatosensory evoked potentials (SEPs) via median nerve stimulation, their paired-pulse ratio (PPR), and temporal order judgment (TOJ). Dependent measures were obtained before TBS and at 5, 25, 50, and 90 min following stimulation. Results indicate similar effects following cTBS and iTBS; increased amplitudes of the second SEP and PPR without amplitude changes to SEP 1, and impairments in TOJ. Metaplasticity was observed such that TOJ impairments following a single cTBS protocol were abolished following consecutive cTBS protocols. Additionally, consecutive iTBS protocols altered the time course of effects when compared with a single iTBS protocol. In conclusion, 30-Hz cTBS and iTBS protocols delivered in isolation induce effects consistent with a TBS-induced reduction in intracortical inhibition within SI. Furthermore, cTBS- and iTBS-induced metaplasticity appear to follow homeostatic and nonhomeostatic rules, respectively. Copyright © 2016 the American Physiological Society.

  4. Brain Monitoring with Electroencephalography and the Electroencephalogram-Derived Bispectral Index During Cardiac Surgery

    PubMed Central

    Kertai, Miklos D.; Whitlock, Elizabeth L.; Avidan, Michael S.

    2011-01-01

    Cardiac surgery presents particular challenges for the anesthesiologist. In addition to standard and advanced monitors typically used during cardiac surgery, anesthesiologists may consider monitoring the brain with raw or processed electroencephalography (EEG). There is strong evidence that a protocol incorporating the processed EEG Bispectral Index (BIS) decreases the incidence intraoperative awareness compared with standard practice. However there is conflicting evidence that incorporating the BIS into cardiac anesthesia practice improves “fast-tracking,” decreases anesthetic drug use, or detects cerebral ischemia. Recent research, including many cardiac surgical patients, shows that a protocol based on BIS monitoring is not superior to a protocol based on end tidal anesthetic concentration monitoring in preventing awareness. There has been a resurgence of interest in the anesthesia literature in limited montage EEG monitoring, including nonproprietary processed indices. This has been accompanied by research showing that with structured training, anesthesiologists can glean useful information from the raw EEG trace. In this review, we discuss both the hypothesized benefits and limitations of BIS and frontal channel EEG monitoring in the cardiac surgical population. PMID:22253267

  5. Inter-device differences in monitoring for goal-directed fluid therapy.

    PubMed

    Thiele, Robert H; Bartels, Karsten; Gan, Tong-Joo

    2015-02-01

    Goal-directed fluid therapy is an integral component of many Enhanced Recovery After Surgery (ERAS) protocols currently in use. The perioperative clinician is faced with a myriad of devices promising to deliver relevant physiologic data to better guide fluid therapy. The goal of this review is to provide concise information to enable the clinician to make an informed decision when choosing a device to guide goal-directed fluid therapy. The focus of many devices used for advanced hemodynamic monitoring is on providing measurements of cardiac output, while other, more recent, devices include estimates of fluid responsiveness based on dynamic indices that better predict an individual's response to a fluid bolus. Currently available technologies include the pulmonary artery catheter, esophageal Doppler, arterial waveform analysis, photoplethysmography, venous oxygen saturation, as well as bioimpedance and bioreactance. The underlying mechanistic principles for each device are presented as well as their performance in clinical trials relevant for goal-directed therapy in ERAS. The ERAS protocols typically involve a multipronged regimen to facilitate early recovery after surgery. Optimizing perioperative fluid therapy is a key component of these efforts. While no technology is without limitations, the majority of the currently available literature suggests esophageal Doppler and arterial waveform analysis to be the most desirable choices to guide fluid administration. Their performance is dependent, in part, on the interpretation of dynamic changes resulting from intrathoracic pressure fluctuations encountered during mechanical ventilation. Evolving practice patterns, such as low tidal volume ventilation as well as the necessity to guide fluid therapy in spontaneously breathing patients, will require further investigation.

  6. [Construction and analysis of a monitoring system with remote real-time multiple physiological parameters based on cloud computing].

    PubMed

    Zhu, Lingyun; Li, Lianjie; Meng, Chunyan

    2014-12-01

    There have been problems in the existing multiple physiological parameter real-time monitoring system, such as insufficient server capacity for physiological data storage and analysis so that data consistency can not be guaranteed, poor performance in real-time, and other issues caused by the growing scale of data. We therefore pro posed a new solution which was with multiple physiological parameters and could calculate clustered background data storage and processing based on cloud computing. Through our studies, a batch processing for longitudinal analysis of patients' historical data was introduced. The process included the resource virtualization of IaaS layer for cloud platform, the construction of real-time computing platform of PaaS layer, the reception and analysis of data stream of SaaS layer, and the bottleneck problem of multi-parameter data transmission, etc. The results were to achieve in real-time physiological information transmission, storage and analysis of a large amount of data. The simulation test results showed that the remote multiple physiological parameter monitoring system based on cloud platform had obvious advantages in processing time and load balancing over the traditional server model. This architecture solved the problems including long turnaround time, poor performance of real-time analysis, lack of extensibility and other issues, which exist in the traditional remote medical services. Technical support was provided in order to facilitate a "wearable wireless sensor plus mobile wireless transmission plus cloud computing service" mode moving towards home health monitoring for multiple physiological parameter wireless monitoring.

  7. Implementation and Validation of a Real-Time Wireless Non-Invasive Physiological Monitoring System in a High-G Environment

    DTIC Science & Technology

    2003-03-01

    51 Figure 30. SpO2 vs G Profile...and physiological monitoring. The system will be composed of a shirt having non- invasive physiological sensors , Global Positioning System (GPS...Positioning System (GPS)), and other sensor technology. It is now possible to transmit large amounts of data at a high rate in real-time. These

  8. Validity of Wearable Activity Monitors during Cycling and Resistance Exercise.

    PubMed

    Boudreaux, Benjamin D; Hebert, Edward P; Hollander, Daniel B; Williams, Brian M; Cormier, Corinne L; Naquin, Mildred R; Gillan, Wynn W; Gusew, Emily E; Kraemer, Robert R

    2018-03-01

    The use of wearable activity monitors has seen rapid growth; however, the mode and intensity of exercise could affect the validity of heart rate (HR) and caloric (energy) expenditure (EE) readings. There is a lack of data regarding the validity of wearable activity monitors during graded cycling regimen and a standard resistance exercise. The present study determined the validity of eight monitors for HR compared with an ECG and seven monitors for EE compared with a metabolic analyzer during graded cycling and resistance exercise. Fifty subjects (28 women, 22 men) completed separate trials of graded cycling and three sets of four resistance exercises at a 10-repetition-maximum load. Monitors included the following: Apple Watch Series 2, Fitbit Blaze, Fitbit Charge 2, Polar H7, Polar A360, Garmin Vivosmart HR, TomTom Touch, and Bose SoundSport Pulse (BSP) headphones. HR was recorded after each cycling intensity and after each resistance exercise set. EE was recorded after both protocols. Validity was established as having a mean absolute percent error (MAPE) value of ≤10%. The Polar H7 and BSP were valid during both exercise modes (cycling: MAPE = 6.87%, R = 0.79; resistance exercise: MAPE = 6.31%, R = 0.83). During cycling, the Apple Watch Series 2 revealed the greatest HR validity (MAPE = 4.14%, R = 0.80). The BSP revealed the greatest HR accuracy during resistance exercise (MAPE = 6.24%, R = 0.86). Across all devices, as exercise intensity increased, there was greater underestimation of HR. No device was valid for EE during cycling or resistance exercise. HR from wearable devices differed at different exercise intensities; EE estimates from wearable devices were inaccurate. Wearable devices are not medical devices, and users should be cautious when using these devices for monitoring physiological responses to exercise.

  9. Towards 24/7 continuous heart rate monitoring.

    PubMed

    Tarniceriu, Adrian; Parak, Jakub; Renevey, Philippe; Nurmi, Marko; Bertschi, Mattia; Delgado-Gonzalo, Ricard; Korhonen, Ilkka

    2016-08-01

    Heart rate (HR) and HR variability (HRV) carry rich information about physical activity, mental and physical load, physiological status, and health of an individual. When combined with activity monitoring and personalized physiological modelling, HR/HRV monitoring may be used for monitoring of complex behaviors and impact of behaviors and external factors on the current physiological status of an individual. Optical HR monitoring (OHR) from wrist provides a comfortable and unobtrusive method for HR/HRV monitoring and is better adhered by users than traditional ECG electrodes or chest straps. However, OHR power consumption is significantly higher than that for ECG based methods due to the measurement principle based on optical illumination of the tissue. We developed an algorithmic approach to reduce power consumption of the OHR in 24/7 HR trending. We use continuous activity monitoring and a fast converging frequency domain algorithm to derive a reliable HR estimate in 7.1s (during outdoor sports, in average) to 10.0s (during daily life). The method allows >80% reduction in power consumption in 24/7 OHR monitoring when average HR monitoring is targeted, without significant reduction in tracking accuracy.

  10. Lentiviral Vectors and Protocols for Creation of Stable hESC Lines for Fluorescent Tracking and Drug Resistance Selection of Cardiomyocytes

    PubMed Central

    Kita-Matsuo, Hiroko; Barcova, Maria; Prigozhina, Natalie; Salomonis, Nathan; Wei, Karen; Jacot, Jeffrey G.; Nelson, Brandon; Spiering, Sean; Haverslag, René; Kim, Changsung; Talantova, Maria; Bajpai, Ruchi; Calzolari, Diego; Terskikh, Alexey; McCulloch, Andrew D.; Price, Jeffrey H.; Conklin, Bruce R.; Chen, H. S. Vincent; Mercola, Mark

    2009-01-01

    Background Developmental, physiological and tissue engineering studies critical to the development of successful myocardial regeneration therapies require new ways to effectively visualize and isolate large numbers of fluorescently labeled, functional cardiomyocytes. Methodology/Principal Findings Here we describe methods for the clonal expansion of engineered hESCs and make available a suite of lentiviral vectors for that combine Blasticidin, Neomycin and Puromycin resistance based drug selection of pure populations of stem cells and cardiomyocytes with ubiquitous or lineage-specific promoters that direct expression of fluorescent proteins to visualize and track cardiomyocytes and their progenitors. The phospho-glycerate kinase (PGK) promoter was used to ubiquitously direct expression of histone-2B fused eGFP and mCherry proteins to the nucleus to monitor DNA content and enable tracking of cell migration and lineage. Vectors with T/Brachyury and α-myosin heavy chain (αMHC) promoters targeted fluorescent or drug-resistance proteins to early mesoderm and cardiomyocytes. The drug selection protocol yielded 96% pure cardiomyocytes that could be cultured for over 4 months. Puromycin-selected cardiomyocytes exhibited a gene expression profile similar to that of adult human cardiomyocytes and generated force and action potentials consistent with normal fetal cardiomyocytes, documenting these parameters in hESC-derived cardiomyocytes and validating that the selected cells retained normal differentiation and function. Conclusion/Significance The protocols, vectors and gene expression data comprise tools to enhance cardiomyocyte production for large-scale applications. PMID:19352491

  11. Cardiovascular Deconditioning in Humans: Human Studies Core

    NASA Technical Reports Server (NTRS)

    Williams, Gordon

    1999-01-01

    Major cardiovascular problems, secondary to cardiovascular deconditioning, may occur on extended space missions. While it is generally assumed that the microgravity state is the primary cause of cardiovascular deconditioning, sleep deprivation and disruption of diurnal rhythms may also play an important role. Factors that could be modified by either or both of these perturbations include: autonomic function and short-term cardiovascular reflexes, vasoreactivity, circadian rhythm of cardiovascular hormones (specifically the renin-angiotensin system) and renal sodium handling and hormonal influences on that process, venous compliance, cardiac mass, and cardiac conduction processes. The purpose of the Human Studies Core is to provide the infrastructure to conduct human experiments which will allow for the assessment of the likely role of such factors in the space travel associated cardiovascular deconditioning process and to develop appropriate countermeasures. The Core takes advantage of a newly-created Intensive Physiologic Monitoring (IPM) Unit at the Brigham and Women's Hospital, Boston, MA, to perform these studies. The Core includes two general experimental protocols. The first protocol involves a head down tilt bed-rest study to simulate microgravity. The second protocol includes the addition of a disruption of circadian rhythms to the simulated microgravity environment. Before and after each of these environmental manipulations, the subjects will undergo acute stressors simulating changes in volume and/or stress, which could occur in space and on return to Earth. The subjects are maintained in a rigidly controlled environment with fixed light/dark cycles, activity pattern, and dietary intake of nutrients, fluids, ions and calories.

  12. In Vivo MRI Quantification of Individual Muscle and Organ Volumes for Assessment of Anabolic Steroid Growth Effects

    PubMed Central

    Wu, Ed X.; Tang, Haiying; Tong, Christopher; Heymsfield, Steve B.; Vasselli, Joseph R.

    2015-01-01

    This study aimed to develop a quantitative and in vivo magnetic resonance imaging (MRI) approach to investigate the muscle growth effects of anabolic steroids. A protocol of MRI acquisition on a standard clinical 1.5 Tesla scanner and quantitative image analysis was established and employed to measure the individual muscle and organ volumes in the intact and castrated guinea pigs undergoing a 16-week treatment protocol by two well-documented anabolic steroids, testosterone and nandrolone, via implanted silastic capsules. High correlations between the in vivo MRI and postmortem dissection measurements were observed for shoulder muscle complex (R = 0.86), masseter (R=0.79), temporalis (R=0.95), neck muscle complex (R=0.58), prostate gland and seminal vesicles (R=0.98), and testis (R=0.96). Furthermore, the longitudinal MRI measurements yielded adequate sensitivity to detect the restoration of growth to or towards normal in castrated guinea pigs by replacing circulating steroid levels to physiological or slightly higher levels, as expected. These results demonstrated that quantitative MRI using a standard clinical scanner provides accurate and sensitive measurement of individual muscles and organs, and this in vivo MRI protocol in conjunction with the castrated guinea pig model constitutes an effective platform to investigate the longitudinal and cross-sectional growth effects of other potential anabolic steroids. The quantitative MRI protocol developed can also be readily adapted for human studies on most clinical MRI scanner to investigate the anabolic steroid growth effects, or monitor the changes in individual muscle and organ volume and geometry following injury, strength training, neuromuscular disorders, and pharmacological or surgical interventions. PMID:18241900

  13. Design of MPPT Controller Monitoring Software Based on QT Framework

    NASA Astrophysics Data System (ADS)

    Meng, X. Z.; Lu, P. G.

    2017-10-01

    The MPPT controller was a hardware device for tracking the maximum power point of solar photovoltaic array. Multiple controllers could be working as networking mode by specific communicating protocol. In this article, based on C++ GUI programming with Qt frame, we designed one sort of desktop application for monitoring and analyzing operational parameter of MPPT controller. The type of communicating protocol for building network was Modbus protocol which using Remote Terminal Unit mode and The desktop application of host computer was connected with all the controllers in the network through RS485 communication or ZigBee wireless communication. Using this application, user could monitor the parameter of controller wherever they were by internet.

  14. Hormonal, metabolic and physiological effects of laparoscopic surgery using a detomidine-buprenorphine combination in standing horses.

    PubMed

    Van Dijk, P; Lankveld, Dpk; Rijkenhuizen, Abm; Jonker, F H

    2003-04-01

    To assess the hormonal, metabolic and physiological effects of laparascopic surgery performed under a sedative analgesic combination of detomidine and buprenorphine in standing horses. Prospective study. Eight healthy adult Dutch Warmblood horses and five healthy adult ponies undergoing laparoscopy were studied. Five healthy adult horses not undergoing laparoscopy were used as a control group. The sedative effect of an initial detomidine and buprenorphine injection was maintained using a continuous infusion of detomidine alone. The heart and respiratory rate, arterial blood pH and arterial oxygen and carbon dioxide tensions were monitored, while blood samples were taken for the measurement of glucose, lactate, cortisol, insulin and nonesterified fatty acids (NEFA). The same variables were monitored in a control group of horses which were sedated, but which did not undergo surgery. At the end of the sedation period the effects of detomidine were antagonized using atipamezole. The protocol provided suitable conditions for standing laparoscopy in horses. Laparoscopy induced obvious metabolic and endocrine responses which, with the exception of NEFA values, were not significantly different from changes found in the control group. While atipamezole did not produce detectable adverse effects, it is possible that anatagonism may not be essential. The technique described reliably produces adequate sedation and analgesia for laparoscopic procedures. The level of sedation/analgesia was controlled by decreasing or increasing the infusion rate. Antagonism of the effects of detomidine may not be necessary in all cases. Copyright © 2003 Association of Veterinary Anaesthetists and American College of Veterinary Anesthesia and Analgesia. Published by Elsevier Ltd. All rights reserved.

  15. Prediction of human core body temperature using non-invasive measurement methods.

    PubMed

    Niedermann, Reto; Wyss, Eva; Annaheim, Simon; Psikuta, Agnes; Davey, Sarah; Rossi, René Michel

    2014-01-01

    The measurement of core body temperature is an efficient method for monitoring heat stress amongst workers in hot conditions. However, invasive measurement of core body temperature (e.g. rectal, intestinal, oesophageal temperature) is impractical for such applications. Therefore, the aim of this study was to define relevant non-invasive measures to predict core body temperature under various conditions. We conducted two human subject studies with different experimental protocols, different environmental temperatures (10 °C, 30 °C) and different subjects. In both studies the same non-invasive measurement methods (skin temperature, skin heat flux, heart rate) were applied. A principle component analysis was conducted to extract independent factors, which were then used in a linear regression model. We identified six parameters (three skin temperatures, two skin heat fluxes and heart rate), which were included for the calculation of two factors. The predictive value of these factors for core body temperature was evaluated by a multiple regression analysis. The calculated root mean square deviation (rmsd) was in the range from 0.28 °C to 0.34 °C for all environmental conditions. These errors are similar to previous models using non-invasive measures to predict core body temperature. The results from this study illustrate that multiple physiological parameters (e.g. skin temperature and skin heat fluxes) are needed to predict core body temperature. In addition, the physiological measurements chosen in this study and the algorithm defined in this work are potentially applicable as real-time core body temperature monitoring to assess health risk in broad range of working conditions.

  16. The Hawaii protocol for scientific monitoring of coffee berry borer: a model for coffee agroecosystems worldwide

    USDA-ARS?s Scientific Manuscript database

    Coffee Berry Borer (CBB) is the most devastating insect pest for coffee crops worldwide. We developed a scientific monitoring protocol aimed at capturing and quantifying the dynamics and impact of this invasive insect pest as well as the development of its host plant across a heterogeneous landscape...

  17. Remote in vivo stress assessment of aquatic animals with microencapsulated biomarkers for environmental monitoring

    NASA Astrophysics Data System (ADS)

    Gurkov, Anton; Shchapova, Ekaterina; Bedulina, Daria; Baduev, Boris; Borvinskaya, Ekaterina; Meglinski, Igor; Timofeyev, Maxim

    2016-11-01

    Remote in vivo scanning of physiological parameters is a major trend in the development of new tools for the fields of medicine and animal physiology. For this purpose, a variety of implantable optical micro- and nanosensors have been designed for potential medical applications. At the same time, the important area of environmental sciences has been neglected in the development of techniques for remote physiological measurements. In the field of environmental monitoring and related research, there is a constant demand for new effective and quick techniques for the stress assessment of aquatic animals, and the development of proper methods for remote physiological measurements in vivo may significantly increase the precision and throughput of analyses in this field. In the present study, we apply pH-sensitive microencapsulated biomarkers to remotely monitor the pH of haemolymph in vivo in endemic amphipods from Lake Baikal, and we compare the suitability of this technique for stress assessment with that of common biochemical methods. For the first time, we demonstrate the possibility of remotely detecting a change in a physiological parameter in an aquatic organism under ecologically relevant stressful conditions and show the applicability of techniques using microencapsulated biomarkers for remote physiological measurements in environmental monitoring.

  18. The Deep Impact Network Experiment Operations Center Monitor and Control System

    NASA Technical Reports Server (NTRS)

    Wang, Shin-Ywan (Cindy); Torgerson, J. Leigh; Schoolcraft, Joshua; Brenman, Yan

    2009-01-01

    The Interplanetary Overlay Network (ION) software at JPL is an implementation of Delay/Disruption Tolerant Networking (DTN) which has been proposed as an interplanetary protocol to support space communication. The JPL Deep Impact Network (DINET) is a technology development experiment intended to increase the technical readiness of the JPL implemented ION suite. The DINET Experiment Operations Center (EOC) developed by JPL's Protocol Technology Lab (PTL) was critical in accomplishing the experiment. EOC, containing all end nodes of simulated spaces and one administrative node, exercised publish and subscribe functions for payload data among all end nodes to verify the effectiveness of data exchange over ION protocol stacks. A Monitor and Control System was created and installed on the administrative node as a multi-tiered internet-based Web application to support the Deep Impact Network Experiment by allowing monitoring and analysis of the data delivery and statistics from ION. This Monitor and Control System includes the capability of receiving protocol status messages, classifying and storing status messages into a database from the ION simulation network, and providing web interfaces for viewing the live results in addition to interactive database queries.

  19. Serial Interface through Stream Protocol on EPICS Platform for Distributed Control and Monitoring

    NASA Astrophysics Data System (ADS)

    Das Gupta, Arnab; Srivastava, Amit K.; Sunil, S.; Khan, Ziauddin

    2017-04-01

    Remote operation of any equipment or device is implemented in distributed systems in order to control and proper monitoring of process values. For such remote operations, Experimental Physics and Industrial Control System (EPICS) is used as one of the important software tool for control and monitoring of a wide range of scientific parameters. A hardware interface is developed for implementation of EPICS software so that different equipment such as data converters, power supplies, pump controllers etc. could be remotely operated through stream protocol. EPICS base was setup on windows as well as Linux operating system for control and monitoring while EPICS modules such as asyn and stream device were used to interface the equipment with standard RS-232/RS-485 protocol. Stream Device protocol communicates with the serial line with an interface to asyn drivers. Graphical user interface and alarm handling were implemented with Motif Editor and Display Manager (MEDM) and Alarm Handler (ALH) command line channel access utility tools. This paper will describe the developed application which was tested with different equipment and devices serially interfaced to the PCs on a distributed network.

  20. A comparison of methods to assess long-term changes in Sonoran Desert vegetation

    USGS Publications Warehouse

    Munson, S.M.; Webb, R.H.; Hubbard, J.A.

    2011-01-01

    Knowledge about the condition of vegetation cover and composition is critical for assessing the structure and function of ecosystems. To effectively quantify the impacts of a rapidly changing environment, methods to track long-term trends of vegetation must be precise, repeatable, and time- and cost-efficient. Measuring vegetation cover and composition in arid and semiarid regions is especially challenging because vegetation is typically sparse, discontinuous, and individual plants are widely spaced. To meet the goal of long-term vegetation monitoring in the Sonoran Desert and other arid and semiarid regions, we determined how estimates of plant species, total vegetation, and soil cover obtained using a widely-implemented monitoring protocol compared to a more time- and resource-intensive plant census. We also assessed how well this protocol tracked changes in cover through 82 years compared to the plant census. Results from the monitoring protocol were comparable to those from the plant census, despite low and variable plant species cover. Importantly, this monitoring protocol could be used as a rapid, "off-the shelf" tool for assessing land degradation (or desertification) in arid and semiarid ecosystems.

  1. A biomedical sensor system for real-time monitoring of astronauts' physiological parameters during extra-vehicular activities.

    PubMed

    Fei, Ding-Yu; Zhao, Xiaoming; Boanca, Cosmin; Hughes, Esther; Bai, Ou; Merrell, Ronald; Rafiq, Azhar

    2010-07-01

    To design and test an embedded biomedical sensor system that can monitor astronauts' comprehensive physiological parameters, and provide real-time data display during extra-vehicle activities (EVA) in the space exploration. An embedded system was developed with an array of biomedical sensors that can be integrated into the spacesuit. Wired communications were tested for physiological data acquisition and data transmission to a computer mounted on the spacesuit during task performances simulating EVA sessions. The sensor integration, data collection and communication, and the real-time data monitoring were successfully validated in the NASA field tests. The developed system may work as an embedded system for monitoring health status during long-term space mission. Copyright 2010 Elsevier Ltd. All rights reserved.

  2. Influence of prior hyperventilation duration on respiratory chemosensitivity and cerebrovascular reactivity during modified hyperoxic rebreathing.

    PubMed

    Boulet, Lindsey M; Tymko, Michael M; Jamieson, Alenna N; Ainslie, Philip N; Skow, Rachel J; Day, Trevor A

    2016-07-01

    What is the central question of this study? We characterized and compared the cardiorespiratory and cerebrovascular responses to the 'Duffin' modified hyperoxic CO2 rebreathing test by randomly altering the prior hyperventilation duration. What is the main finding and its importance? Our main finding was that prior hyperventilation duration (1, 3 or 5 min) had no effect on cardiorespiratory and cerebrovascular responses to the hyperoxic rebreathing test, within individuals. These findings suggest that the standard 5 min prior hyperventilation duration used to clear body CO2 stores is unnecessary and can reasonably be shortened to 1 min, reducing protocol times and improving participant comfort. The 'Duffin' modified hyperoxic rebreathing test allows investigators to characterize and quantify the ventilatory and cerebrovascular responses to CO2 across a large physiological range, allowing quantification of basal ventilation and the ventilatory recruitment threshold (VRT). Although the standard protocol includes 5 min of prior hyperventilation to clear body CO2 stores, there is no experimental evidence that a full 5 min is required. We hypothesized that there would be no within-individual differences in the cardiorespiratory or cerebrovascular responses to rebreathing with shortened hyperventilation duration prior to hyperoxic rebreathing. Using a rebreathing apparatus, transcranial Doppler ultrasound and beat-to-beat blood pressure monitoring, we tested 19 participants in the supine position using three randomly assigned hyperoxic rebreathing tests with 1, 3 or 5 min of prior hyperventilation. We measured VRT (in Torr CO2 ), time to VRT (in seconds), central respiratory chemoreflex (breathing frequency, tidal volume and minute ventilation), cerebrovascular (middle and posterior cerebral artery velocity) and cardiovascular (heart rate and mean arterial pressure) responses to CO2 during hyperoxic rebreathing. Using linear regression and repeated-measures ANOVAs, we found no differences in any of the cardiorespiratory or cerebrovascular response magnitudes between trials (P > 0.05). The only difference observed was in the time to VRT (in seconds), whereby 1 min prior hyperventilation duration was shorter (135.4 ± 19.7 s) than with 3 or 5 min prior hyperventilation (176.3 ± 15.1 and 187.2 ± 11.6 s, respectively; P < 0.001). Our findings indicate that 5 min of prior hyperventilation is unnecessary during modified rebreathing when using it to quantify respiratory or cerebrovascular responses and can be reasonably shortened to 1 min, reducing protocol times and improving participant comfort. © 2016 The Authors. Experimental Physiology © 2016 The Physiological Society.

  3. Cardiovascular Deconditioning in Humans: Alteration in Cardiovascular Regulation and Function During Simulated Microgravity

    NASA Technical Reports Server (NTRS)

    Cohen, Richard

    1999-01-01

    Alterations in cardiovascular regulation and function that occur during and after space flight have been reported. These alterations are manifested, for example, by reduced orthostatic tolerance upon reentry to the earth's gravity from space. However, the precise physiologic mechanisms responsible for these alterations remain to be fully elucidated. Perhaps, as a result, effective countermeasures have yet to be developed. In this project we apply a powerful, new method - cardiovascular system identification (CSI) - for the study of the effects of space flight on the cardiovascular system so that effective countermeasures can be developed. CSI involves the mathematical analysis of second-to-second fluctuations in non-invasively measured heart rate, arterial blood pressure (ABP), and instantaneous lung volume (ILV - respiratory activity) in order to characterize quantitatively the physiologic mechanisms responsible for the couplings between these signals. Through the characterization of all the physiologic mechanisms coupling these signals, CSI provides a model of the closed-loop cardiovascular regulatory state in an individual subject. The model includes quantitative descriptions of the heart rate baroreflex, autonomic function, as well as other important physiologic mechanisms. We are in the process of incorporating beat-to-beat fluctuations of stroke volume into the CSI technique in order to quantify additional physiologic mechanisms such as those involved in control of peripheral vascular resistance and alterations in cardiac contractility. We apply CSI in conjunction with the two general protocols of the Human Studies Core project. The first protocol involves ground-based, human head down tilt bed rest to simulate microgravity and acute stressors - upright tilt, standing and bicycle exercise - to provide orthostatic and exercise challenges. The second protocol is intended to be the same as the first but with the addition of sleep deprivation to determine whether this contributes to cardiovascular alterations. In these studies, we focus on the basic physiologic mechanisms responsible for the alterations in cardiovascular regulation and function during the simulated microgravity in order to formulate hypotheses regarding what countermeasures are likely to be most effective. Compared to our original proposal, the protocol we are using has been slightly modified to lengthen the bed rest period to 16 days and streamline the data collection. These modifications provide us data on a longer bed rest period and have enabled us to increase our subject throughput. Based on review of our preliminary data we have decided to test a countermeasure which is applied the very end of the bed rest period. We will use the same bed rest protocol to test this countermeasure. We anticipate completing the baseline data collection in our first protocol plus testing of the countermeasure in an additional eight subjects, at which time we plan to initiate the second protocol which includes sleep deprivation. In future studies, we plan to apply CSI to test other potential countermeasures in conjunction with the same bed rest, sleep deprivation and acute stressor models. We also anticipate applying CSI for studying astronauts before and after space flight and ultimately, during space flight. The application of CSI is providing information relevant to the development and evaluation of effective countermeasures allowing humans to adapt appropriately upon re-exposure to a gravity field, and to live and work for longer periods of time in microgravity.

  4. Landbird Monitoring Protocol for National Parks in the North Coast and Cascades Network

    USGS Publications Warehouse

    Siegel, Rodney B.; Wilkerson, Robert L.; Jenkins, Kurt J.; Kuntz, Robert C.; Boetsch, John R.; Schaberl, James P.; Happe, Patricia J.

    2007-01-01

    This protocol narrative outlines the rationale, sampling design and methods for monitoring landbirds in the North Coast and Cascades Network (NCCN) during the breeding season. The NCCN, one of 32 networks of parks in the National Park System, comprises seven national park units in the Pacific Northwest, including three large, mountainous, natural area parks (Mount Rainier [MORA] and Olympic [OLYM] National Parks, North Cascades National Park Service Complex [NOCA]), and four small historic cultural parks (Ebey's Landing National Historical Reserve [EBLA], Lewis and Clark National Historical Park [LEWI], Fort Vancouver National Historical Park [FOVA], and San Juan Island National Historical Park [SAJH]). The protocol reflects decisions made by the NCCN avian monitoring group, which includes NPS representatives from each of the large parks in the Network as well as personnel from the U.S. Geological Survey Forest and Rangeland Ecosystem Science Center (USGS-FRESC) Olympic Field Station, and The Institute for Bird Populations, at meetings held between 2000 (Siegel and Kuntz, 2000) and 2005. The protocol narrative describes the monitoring program in relatively broad terms, and its structure and content adhere to the outline and recommendations developed by Oakley and others (2003) and adopted by NPS. Finer details of the methodology are addressed in a set of standard operating procedures (SOPs) that accompany the protocol narrative. We also provide appendixes containing additional supporting materials that do not clearly belong in either the protocol narrative or the standard operating procedures.

  5. Informal trail monitoring protocols: Denali National Park and Preserve. Final Report, October 2011

    USGS Publications Warehouse

    Marion, Jeffrey L.; Wimpey, Jeremy F.

    2011-01-01

    Managers at Alaska?s Denali National Park and Preserve (DENA) sponsored this research to assess and monitor visitor-created informal trails (ITs). DENA is located in south-central Alaska and managed as a six million acre wilderness park. This program of research was guided by the following objectives: (1) Investigate alternative methods for monitoring the spatial distribution, aggregate lineal extent, and tread conditions of informal (visitor-created) trails within the park. (2) In consultation with park staff, develop, pilot test, and refine cost-effective and scientifically defensible trail monitoring procedures that are fully integrated with the park?s Geographic Information System. (3) Prepare a technical report that compiles and presents research results and their management implications. This report presents the protocol development and field testing process, illustrates the types of data produced by their application, and provides guidance for their application and use. The protocols described provide managers with an efficient means to document and monitor IT conditions in settings ranging from pristine to intensively visited.

  6. Monitoring well utility in a heterogeneous DNAPL source zone area: Insights from proximal multilevel sampler wells and sampling capture-zone modelling

    NASA Astrophysics Data System (ADS)

    McMillan, Lindsay A.; Rivett, Michael O.; Wealthall, Gary P.; Zeeb, Peter; Dumble, Peter

    2018-03-01

    Groundwater-quality assessment at contaminated sites often involves the use of short-screen (1.5 to 3 m) monitoring wells. However, even over these intervals considerable variation may occur in contaminant concentrations in groundwater adjacent to the well screen. This is especially true in heterogeneous dense non-aqueous phase liquid (DNAPL) source zones, where cm-scale contamination variability may call into question the effectiveness of monitoring wells to deliver representative data. The utility of monitoring wells in such settings is evaluated by reference to high-resolution multilevel sampler (MLS) wells located proximally to short-screen wells, together with sampling capture-zone modelling to explore controls upon well sample provenance and sensitivity to monitoring protocols. Field data are analysed from the highly instrumented SABRE research site that contained an old trichloroethene source zone within a shallow alluvial aquifer at a UK industrial facility. With increased purging, monitoring-well samples tend to a flow-weighted average concentration but may exhibit sensitivity to the implemented protocol and degree of purging. Formation heterogeneity adjacent to the well-screen particularly, alongside pump-intake position and water level, influence this sensitivity. Purging of low volumes is vulnerable to poor reproducibility arising from concentration variability predicted over the initial 1 to 2 screen volumes purged. Marked heterogeneity may also result in limited long-term sample concentration stabilization. Development of bespoke monitoring protocols, that consider screen volumes purged, alongside water-quality indicator parameter stabilization, is recommended to validate and reduce uncertainty when interpreting monitoring-well data within source zone areas. Generalised recommendations on monitoring well based protocols are also developed. A key monitoring well utility is their proportionately greater sample draw from permeable horizons constituting a significant contaminant flux pathway and hence representative fraction of source mass flux. Acquisition of complementary, high-resolution, site monitoring data, however, vitally underpins optimal interpretation of monitoring-well datasets and appropriate advancement of a site conceptual model and remedial implementation.

  7. Which indicators for measuring the daily physical activity? An overview on the challenges and technology limits for Telehealth applications.

    PubMed

    Tagliente, Irene; Solvoll, Terje; Trieste, Leopoldo; De Cecco, Carlo N; Murgia, Fabrizio; Bella, Sergio

    2016-09-14

    Obesity is one of the biggest drivers of preventable chronic diseases and healthcare costs in Worldwide. Different prevention activities are suggested. By monitoring daily energy expenditure (EE) could be possible make personalized diets and programming physical activity. In this, physical inactivity is one of the most important public health problems. Some studies refer the effort of the international community in promoting physical activities. Physical activity can be promoted only by increasing citizens' empowerment on taking care of their health, and it passes from the improving of individual information. Technology can offer solutions and metrics for monitoring and measuring daily activity by interacting with individuals, sharing information and feedbacks. In this study we review indicators of total energy expenditure and weaknesses of available devices in assessing these parameters. Literature review and technology testing EuNetHta core model. For the clinical aspects, it is fundamental to take into account all the factor that can influence the personal energy expenditure as: heart rate, blood pressure and thermoregulation (influenced by the body temperature). In this study we focused the attention on the importance of tools to encourage the physical activity. We made an analysis of the factor that can influence the right analysis of energy expenditure and at the same time the energy regime. A punctual monitoring of the exercise regime could be helpful in Telemedicine application as Telemonitorig. More study are needed to value the impact of physical activity tracker in Telemonitorig protocols. On the assessment of the energy expenditure, critical issues are related to the physiological data acquisition. Sensors connected with mobile devices could be important tools for disease prevention and interventions affecting health behaviors. New devices applications are potential useful for telemedicine assistance, but security of data and the related communication protocol limits should be taking into account.

  8. Physiological and psychological effects of testosterone during severe energy deficit and recovery: A study protocol for a randomized, placebo-controlled trial for Optimizing Performance for Soldiers (OPS).

    PubMed

    Pasiakos, Stefan M; Berryman, Claire E; Karl, J Philip; Lieberman, Harris R; Orr, Jeb S; Margolis, Lee M; Caldwell, John A; Young, Andrew J; Montano, Monty A; Evans, William J; Vartanian, Oshin; Carmichael, Owen T; Gadde, Kishore M; Harris, Melissa; Rood, Jennifer C

    2017-07-01

    The physiological consequences of severe energy deficit include hypogonadism and the loss of fat-free mass. Prolonged energy deficit also impacts physical performance, mood, attentiveness, and decision-making capabilities. This study will determine whether maintaining a eugonadal state during severe, sustained energy deficit attenuates physiological decrements and maintains mental performance. This study will also assess the effects of normalizing testosterone levels during severe energy deficit and recovery on gut health and appetite regulation. Fifty physically active men will participate in a 3-phase, randomized, placebo-controlled study. After completing a 14-d, energy-adequate, diet acclimation phase (protein: 1.6g∙kg -1 ∙d -1 ; fat: 30% total energy intake), participants will be randomized to undergo a 28-d, 55% energy deficit phase with (DEF+TEST: 200mg testosterone enanthate per week) or without (DEF) exogenous testosterone. Diet and physical activity will be rigorously controlled. Recovery from the energy deficit (ad libitum diet, no testosterone) will be assessed until body mass has been recovered within ±2.5% of initial body mass. Body composition, stable isotope methodologies, proteomics, muscle biopsies, whole-room calorimetry, molecular biology, activity/sleep monitoring, personality and cognitive function assessments, functional MRI, and comprehensive biochemistries will be used to assess physiological and psychological responses to energy restriction and recovery feeding while volunteers are in an expected hypogonadal versus eugonadal state. The Optimizing Performance for Soldiers (OPS) study aims to determine whether preventing hypogonadism will mitigate declines in physical and mental function that typically occur during prolonged energy deficit, and the efficacy of testosterone replacement on recovery from severe underfeeding. NCT02734238. Copyright © 2017. Published by Elsevier Inc.

  9. The Effectiveness of Hands-on Health Informatics Skills Exercises in the Multidisciplinary Smart Home Healthcare and Health Informatics Training Laboratories.

    PubMed

    Sapci, A H; Sapci, H A

    2017-10-01

    This article aimed to evaluate the effectiveness of newly established innovative smart home healthcare and health informatics laboratories, and a novel laboratory course that focuses on experiential health informatics training, and determine students' self-confidence to operate wireless home health monitoring devices before and after the hands-on laboratory course. Two web-based pretraining and posttraining questionnaires were sent to 64 students who received hands-on training with wireless remote patient monitoring devices in smart home healthcare and health informatics laboratories. All 64 students completed the pretraining survey (100% response rate), and 49 students completed the posttraining survey (76% response rate). The quantitative data analysis showed that 95% of students had an interest in taking more hands-on laboratory courses. Sixty-seven percent of students had no prior experience with medical image, physiological data acquisition, storage, and transmission protocols. After the hands-on training session, 75.51% of students expressed improved confidence about training patients to measure blood pressure monitor using wireless devices. Ninety percent of students preferred to use a similar experiential approach in their future learning experience. Additionally, the qualitative data analysis demonstrated that students were expecting to have more courses with hands-on exercises and integration of technology-enabled delivery and patient monitoring concepts into the curriculum. This study demonstrated that the multidisciplinary smart home healthcare and health informatics training laboratories and the hands-on exercises improved students' technology adoption rates and their self-confidence in using wireless patient monitoring devices. Schattauer GmbH Stuttgart.

  10. Middle infrared optoelectronic absorption systems for monitoring physiological glucose solutions

    NASA Astrophysics Data System (ADS)

    Martin, W. Blake

    Tight monitoring of the glucose levels for diabetic individuals is essential to control long-term complications. A definitive diabetes management system has yet to be developed for the diabetic. This research investigates the application of middle infrared absorption frequencies for monitoring glucose levels in biological solutions. Three frequencies were identified using a Fourier transform infrared spectrometer and correlated to changes in glucose concentrations. The 1035 +/- 1 cm-1 frequency was determined to be the best representative frequency. Other biological molecules contributed no significant interference to monitoring glucose absorption. A second frequency at 1193 cm-1 was suggested as a representative background absorption frequency, which could be used for more accurate glucose absorption values. Next, a quantum cascade laser optoelectronic absorption system was designed and developed to monitor glucose. After careful alignment and design, the system was used to monitor physiological glucose concentrations. Correlation at 1036 cm-1 with glucose changes was comparable to the previous results. The use of the background absorption frequency was verified. This frequency essentially acts as a calibrating frequency to adjust in real-time to any changes in the background absorption that may alter the accuracy of the predicted glucose value. An evanescent wave cavity ring-down spectroscopy technique was explored to monitor molecules in a biological solution. Visible light at 425 nm was used to monitor hemoglobin in control urine samples. An adsorption isotherm for hemoglobin was detectable to limit of 5.8 nM. Evanescent wave cavity ring-down spectroscopy would be useful for a glucose solution. Given an equivalent system designed for the middle infrared, the molar extinction coefficient of glucose allows for a detectable limit of 45 mg/dl for a free-floating glucose solution, which is below normal physiological concentrations. The future use of a hydrophobic coating could limit the adsorption of glucose to the surface but still allow physiological monitoring. Three middle infrared optoelectronic absorption systems have been designed for monitoring glucose in a physiological solution. The systems are applicable for the monitoring of glucose. These systems may lead to a useful monitoring device for the diabetic so that the universal complications associated with the disease may be limited.

  11. Lichen elements as pollution indicators: evaluation of methods for large monitoring programmes

    Treesearch

    Susan Will-Wolf; Sarah Jovan; Michael C. Amacher

    2017-01-01

    Lichen element content is a reliable indicator for relative air pollution load in research and monitoring programmes requiring both efficiency and representation of many sites. We tested the value of costly rigorous field and handling protocols for sample element analysis using five lichen species. No relaxation of rigour was supported; four relaxed protocols generated...

  12. Learning temporal rules to forecast instability in continuously monitored patients.

    PubMed

    Guillame-Bert, Mathieu; Dubrawski, Artur; Wang, Donghan; Hravnak, Marilyn; Clermont, Gilles; Pinsky, Michael R

    2017-01-01

    Inductive machine learning, and in particular extraction of association rules from data, has been successfully used in multiple application domains, such as market basket analysis, disease prognosis, fraud detection, and protein sequencing. The appeal of rule extraction techniques stems from their ability to handle intricate problems yet produce models based on rules that can be comprehended by humans, and are therefore more transparent. Human comprehension is a factor that may improve adoption and use of data-driven decision support systems clinically via face validity. In this work, we explore whether we can reliably and informatively forecast cardiorespiratory instability (CRI) in step-down unit (SDU) patients utilizing data from continuous monitoring of physiologic vital sign (VS) measurements. We use a temporal association rule extraction technique in conjunction with a rule fusion protocol to learn how to forecast CRI in continuously monitored patients. We detail our approach and present and discuss encouraging empirical results obtained using continuous multivariate VS data from the bedside monitors of 297 SDU patients spanning 29 346 hours (3.35 patient-years) of observation. We present example rules that have been learned from data to illustrate potential benefits of comprehensibility of the extracted models, and we analyze the empirical utility of each VS as a potential leading indicator of an impending CRI event. © The Author 2016. Published by Oxford University Press on behalf of the American Medical Informatics Association. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  13. Validation of the G.LAB MD2200 wrist blood pressure monitor according to the European Society of Hypertension, the British Hypertension Society, and the International Organization for Standardization Protocols.

    PubMed

    Liu, Ze-Yu; Zhang, Qing-Han; Ye, Xiao-Lei; Liu, Da-Peng; Cheng, Kang; Zhang, Chun-Hai; Wan, Yi

    2017-04-01

    To validate the G.LAB MD2200 automated wrist blood pressure (BP) monitors according to the European Society of Hypertension International Protocol (ESH-IP) revision 2010, the British Hypertension Society (BHS), and the International Organization for Standardization (ISO) 81060-2:2013 protocols. The device was assessed on 33 participants according to the ESH requirements and was then tested on 85 participants according to the BHS and ISO 81060-2:2013 criteria. The validation procedures and data analysis followed the protocols precisely. The G.LAB MD2200 devices passed all parts of ESH-IP revision 2010 for both systolic and diastolic BP, with a device-observer difference of 2.15±5.51 and 1.51±5.16 mmHg, respectively. The device achieved A/A grading for the BHS protocol and it also fulfilled the criteria of ISO 81060-2:2013, with mean differences of systolic and diastolic BP between the device and the observer of 2.19±5.21 and 2.11±4.70 mmHg, respectively. The G.LAB MD2200 automated wrist BP monitor passed the ESH-IP revision 2010 and the ISO 81060-2:2013 protocol, and achieved the A/A grade of the BHS protocol, which can be recommended for self-measurement in the general population.

  14. Protocol for Landsat-Based Monitoring of Landscape Dynamics at North Coast and Cascades Network Parks

    USGS Publications Warehouse

    Kennedy, Robert E.; Cohen, Warren B.; Kirschbaum, Alan A.; Haunreiter, Erik

    2007-01-01

    Background and Objectives As part of the National Park Service's larger goal of developing long-term monitoring programs in response to the Natural Resource Challenge of 2000, the parks of the North Coast and Cascades Network (NCCN) have determined that monitoring of landscape dynamics is necessary to track ecosystem health (Weber and others, 2005). Landscape dynamics refer to a broad suite of ecological, geomorphological, and anthropogenic processes occurring across broad spatial scales. The NCCN has sought protocols that would leverage remote-sensing technologies to aid in monitoring landscape dynamics.

  15. Flexible Sensing Electronics for Wearable/Attachable Health Monitoring.

    PubMed

    Wang, Xuewen; Liu, Zheng; Zhang, Ting

    2017-07-01

    Wearable or attachable health monitoring smart systems are considered to be the next generation of personal portable devices for remote medicine practices. Smart flexible sensing electronics are components crucial in endowing health monitoring systems with the capability of real-time tracking of physiological signals. These signals are closely associated with body conditions, such as heart rate, wrist pulse, body temperature, blood/intraocular pressure and blood/sweat bio-information. Monitoring such physiological signals provides a convenient and non-invasive way for disease diagnoses and health assessments. This Review summarizes the recent progress of flexible sensing electronics for their use in wearable/attachable health monitoring systems. Meanwhile, we present an overview of different materials and configurations for flexible sensors, including piezo-resistive, piezo-electrical, capacitive, and field effect transistor based devices, and analyze the working principles in monitoring physiological signals. In addition, the future perspectives of wearable healthcare systems and the technical demands on their commercialization are briefly discussed. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  16. Stress hormone concentration in Rocky Mountain populations of the American pika (Ochotona princeps)

    PubMed Central

    Wilkening, Jennifer L.; Ray, Chris; Sweazea, Karen L.

    2013-01-01

    The American pika (Ochotona princeps) is considered a sentinel species for detecting ecological effects of climate change. Pikas are declining within a large portion of their range, but previous studies have focused only on local pika extinction as a metric of change. We designed a procedure which can provide an earlier warning signal, based on non-invasive sampling and analysis of physiological stress in living pikas. Pikas were sampled at several locations in the Rocky Mountains for the measurement of glucocorticoid metabolites (GCMs) in faeces. Using a time series of faecal pellets from 12 individuals, we detected a significant increase in faecal GCM level in response to capture, thus biologically validating the use of a corticosterone enzyme immunoassay. We also established baseline, peak, and post-peak GCM concentrations for pikas in the Rocky Mountains, which varied according to gender and individual. This is the first study to measure stress hormone metabolites in any species of pika. The methods developed and validated in this study can be used to add non-invasive measurements of physiological stress to pika monitoring programmes and other research designed to assess pika vulnerability to predicted changes in climate. Pika monitoring programmes currently in place use a protocol that relates current site use by pikas with data on local habitat characteristics, such as elevation, to infer potential effects of climate change. Data generated by these monitoring studies can be used to identify the trends in site use by pikas in relationship to habitat covariates. However, this approach does not take into account the role of behavioural thermoregulation and the pika's use of microhabitats to ameliorate variations in climate. Incorporating a stress metric, such as GCM concentration, will provide relatively direct evidence for or against the hypothesis that pikas can be stressed by climate regardless of behavioural adaptations. PMID:27293611

  17. Pulse Power--A Heart Physiology Program for Children.

    ERIC Educational Resources Information Center

    Hinson, Curt

    1994-01-01

    Primary grade students at a Delaware elementary school currently participate in the Pulse Power heart physiology program. Students receive mastery instruction and use heart monitors to exercise performance throughout the 6-phase program. Data from homework and from the heart monitors identify student progress, knowledge, and cardiovascular…

  18. Comprehensive multilevel in vivo and in vitro analysis of heart rate fluctuations in mice by ECG telemetry and electrophysiology.

    PubMed

    Fenske, Stefanie; Pröbstle, Rasmus; Auer, Franziska; Hassan, Sami; Marks, Vanessa; Pauza, Danius H; Biel, Martin; Wahl-Schott, Christian

    2016-01-01

    The normal heartbeat slightly fluctuates around a mean value; this phenomenon is called physiological heart rate variability (HRV). It is well known that altered HRV is a risk factor for sudden cardiac death. The availability of genetic mouse models makes it possible to experimentally dissect the mechanism of pathological changes in HRV and its relation to sudden cardiac death. Here we provide a protocol that allows for a comprehensive multilevel analysis of heart rate (HR) fluctuations. The protocol comprises a set of techniques that include in vivo telemetry and in vitro electrophysiology of intact sinoatrial network preparations or isolated single sinoatrial node (SAN) cells. In vitro preparations can be completed within a few hours, with data acquisition within 1 d. In vivo telemetric ECG requires 1 h for surgery and several weeks for data acquisition and analysis. This protocol is of interest to researchers investigating cardiovascular physiology and the pathophysiology of sudden cardiac death.

  19. Real time monitoring to the odour of excrement for health of infants and elderly completely bedridden

    NASA Astrophysics Data System (ADS)

    Ye, Jiancheng; Huang, Guoliang

    2017-01-01

    In the domain of biomedical signals measurements, monitoring human physiological parameters is an important issue. With the rapid development of wireless body area network, it makes monitor, transmit and record physiological parameters faster and more convenient. Infants and the elderly completely bedridden are two special groups of the society who need more medical care. According to researches investigating current frontier domains and the market products, the detection of physiological parameters from the excrement is rare. However, urine and faeces contain a large number of physiological information, which are high relative to health. The mainly distributed odour from urine is NH4 and the distributed odour from feces is mainly H2S, which are both could be detected by the sensors. In this paper, we introduce the design and implementation of a portable wireless device based on body area network for real time monitoring to the odour of excrement for health of infants and the elderly completely bedridden. The device not only could monitor in real time the emitted odour of faeces and urine for health analysis, but also measures the body temperature and environment humidity, and send data to the mobile phone of paramedics to alarm or the server for storage and process, which has prospect to monitoring infants and the paralysis elderly.

  20. Atomic force microscopy of model lipid membranes.

    PubMed

    Morandat, Sandrine; Azouzi, Slim; Beauvais, Estelle; Mastouri, Amira; El Kirat, Karim

    2013-02-01

    Supported lipid bilayers (SLBs) are biomimetic model systems that are now widely used to address the biophysical and biochemical properties of biological membranes. Two main methods are usually employed to form SLBs: the transfer of two successive monolayers by Langmuir-Blodgett or Langmuir-Schaefer techniques, and the fusion of preformed lipid vesicles. The transfer of lipid films on flat solid substrates offers the possibility to apply a wide range of surface analytical techniques that are very sensitive. Among them, atomic force microscopy (AFM) has opened new opportunities for determining the nanoscale organization of SLBs under physiological conditions. In this review, we first focus on the different protocols generally employed to prepare SLBs. Then, we describe AFM studies on the nanoscale lateral organization and mechanical properties of SLBs. Lastly, we survey recent developments in the AFM monitoring of bilayer alteration, remodeling, or digestion, by incubation with exogenous agents such as drugs, proteins, peptides, and nanoparticles.

  1. Nutritional support of children in the intensive care unit.

    PubMed Central

    Seashore, J. H.

    1984-01-01

    Nutritional support is an integral and essential part of the management of 5-10 percent of hospitalized children. Children in the intensive care unit are particularly likely to develop malnutrition because of the nature and duration of their illness, and their inability to eat by mouth. This article reviews the physiology of starvation and the development of malnutrition in children. A method of estimating the nutritional requirements of children is presented. The techniques of nutritional support, including enteral, peripheral, and central parenteral nutrition are discussed in detail. Appropriate formulas are given for different age groups. Electrolyte, vitamin, and mineral supplements are discussed. Guidelines are provided for choosing between peripheral and central total parenteral nutrition. A monitoring protocol is suggested and complications of nutritional therapy are reviewed. Safe and effective nutritional support requires considerable investment of time and effort by members of the nutrition team. PMID:6433586

  2. Preclinical experimental stress studies: protocols, assessment and comparison.

    PubMed

    Bali, Anjana; Jaggi, Amteshwar Singh

    2015-01-05

    Stress is a state of threatened homeostasis during which a variety of adaptive processes are activated to produce physiological and behavioral changes. Preclinical models are pivotal for understanding these physiological or pathophysiological changes in the body in response to stress. Furthermore, these models are also important for the development of novel pharmacological agents for stress management. The well described preclinical stress models include immobilization, restraint, electric foot shock and social isolation stress. Stress assessment in animals is done at the behavioral level using open field, social interaction, hole board test; at the biochemical level by measuring plasma corticosterone and ACTH; at the physiological level by measuring food intake, body weight, adrenal gland weight and gastric ulceration. Furthermore the comparison between different stressors including electric foot shock, immobilization and cold stressor is described in terms of intensity, hormonal release, protein changes in brain, adaptation and sleep pattern. This present review describes these preclinical stress protocols, and stress assessment at different levels. Copyright © 2014 Elsevier B.V. All rights reserved.

  3. Smartphone-Based Monitoring of Objective and Subjective Data in Affective Disorders: Where Are We and Where Are We Going? Systematic Review.

    PubMed

    Dogan, Ezgi; Sander, Christian; Wagner, Xenija; Hegerl, Ulrich; Kohls, Elisabeth

    2017-07-24

    Electronic mental health interventions for mood disorders have increased rapidly over the past decade, most recently in the form of various systems and apps that are delivered via smartphones. We aim to provide an overview of studies on smartphone-based systems that combine subjective ratings with objectively measured data for longitudinal monitoring of patients with affective disorders. Specifically, we aim to examine current knowledge on: (1) the feasibility of, and adherence to, such systems; (2) the association of monitored data with mood status; and (3) the effects of monitoring on clinical outcomes. We systematically searched PubMed, Web of Science, PsycINFO, and the Cochrane Central Register of Controlled Trials for relevant articles published in the last ten years (2007-2017) by applying Boolean search operators with an iterative combination of search terms, which was conducted in February 2017. Additional articles were identified via pearling, author correspondence, selected reference lists, and trial protocols. A total of 3463 unique records were identified. Twenty-nine studies met the inclusion criteria and were included in the review. The majority of articles represented feasibility studies (n=27); two articles reported results from one randomized controlled trial (RCT). In total, six different self-monitoring systems for affective disorders that used subjective mood ratings and objective measurements were included. These objective parameters included physiological data (heart rate variability), behavioral data (phone usage, physical activity, voice features), and context/environmental information (light exposure and location). The included articles contained results regarding feasibility of such systems in affective disorders, showed reasonable accuracy in predicting mood status and mood fluctuations based on the objectively monitored data, and reported observations about the impact of monitoring on clinical state and adherence of patients to the system usage. The included observational studies and RCT substantiate the value of smartphone-based approaches for gathering long-term objective data (aside from self-ratings to monitor clinical symptoms) to predict changes in clinical states, and to investigate causal inferences about state changes in patients with affective disorders. Although promising, a much larger evidence-base is necessary to fully assess the potential and the risks of these approaches. Methodological limitations of the available studies (eg, small sample sizes, variations in the number of observations or monitoring duration, lack of RCT, and heterogeneity of methods) restrict the interpretability of the results. However, a number of study protocols stated ambitions to expand and intensify research in this emerging and promising field. ©Ezgi Dogan, Christian Sander, Xenija Wagner, Ulrich Hegerl, Elisabeth Kohls. Originally published in the Journal of Medical Internet Research (http://www.jmir.org), 24.07.2017.

  4. Detailed analysis of routing protocols with different network limitations

    NASA Astrophysics Data System (ADS)

    Masood, Mohsin; Abuhelala, Mohamed; Glesk, Ivan

    2016-12-01

    In network communication field, routing protocols have got a significant role which are not only used in networks to handle the user data but also to monitor the different network environments. Dynamic routing protocols such as OSPF, EIGRP and RIP are used for forwarding user data to its destination by instantly detecting the dynamic changes across the network. The dynamic changes in the network can be in the form of topological changes, congestions, links failure etc. Therefore, it becomes a challenge to develop and implement dynamic routing protocols that fulfills the network requirements. Hence, each routing protocol has its own characteristics such as convergence activity, routing metric, routing table etc. and will perform differently in various network environments. This paper presents a comprehensive study of static and dynamic routing, along with dynamic routing protocols. Experiments that are conducted under various network limitations are presented using the OPNET tool. The performance of each of dynamic routing protocols are monitored and explained in the form of simulated results using network parameters. The results are analyzed, in order to provide a clear understanding of each protocol performance for the selection of the proper protocol for a given network environment.

  5. Direct data access protocols benchmarking on DPM

    NASA Astrophysics Data System (ADS)

    Furano, Fabrizio; Devresse, Adrien; Keeble, Oliver; Mancinelli, Valentina

    2015-12-01

    The Disk Pool Manager is an example of a multi-protocol, multi-VO system for data access on the Grid that went though a considerable technical evolution in the last years. Among other features, its architecture offers the opportunity of testing its different data access frontends under exactly the same conditions, including hardware and backend software. This characteristic inspired the idea of collecting monitoring information from various testbeds in order to benchmark the behaviour of the HTTP and Xrootd protocols for the use case of data analysis, batch or interactive. A source of information is the set of continuous tests that are run towards the worldwide endpoints belonging to the DPM Collaboration, which accumulated relevant statistics in its first year of activity. On top of that, the DPM releases are based on multiple levels of automated testing that include performance benchmarks of various kinds, executed regularly every day. At the same time, the recent releases of DPM can report monitoring information about any data access protocol to the same monitoring infrastructure that is used to monitor the Xrootd deployments. Our goal is to evaluate under which circumstances the HTTP-based protocols can be good enough for batch or interactive data access. In this contribution we show and discuss the results that our test systems have collected under the circumstances that include ROOT analyses using TTreeCache and stress tests on the metadata performance.

  6. High-resolution Mass Spectrometry of Skin Mucus for Monitoring Physiological Impacts in Fish Exposed to Wastewater Effluent at a Great Lakes AOC

    EPA Science Inventory

    High-resolution mass spectrometry is advantageous for monitoring physiological impacts and contaminant biotransformation products in fish exposed to complex wastewater effluent. We evaluated this technique using skin mucus from male and female fathead minnows (Pimephales promela...

  7. High‐resolution mass spectrometry of skin mucus for monitoring physiological impacts and contaminant biotransformation products in fathead minnows exposed to wastewater effluent

    EPA Science Inventory

    High‐resolution mass spectrometry is advantageous for monitoring physiological impacts and contaminant biotransformation products in fish exposed to complex wastewater effluent. We evaluated this technique using skin mucus from male and female fathead minnows (Pimephales pr...

  8. Stress Hormones and their Regulation in a Captive Dolphin Population

    DTIC Science & Technology

    2013-09-30

    multiple environmental stressors, many of which are anthropogenic. The resulting stress response is mounted to manage immediate physiological needs. When...variability in stress hormones and 2) evaluating physiological and metabolic alterations that occur during stress in bottlenose dolphin. The...specific research objectives of this effort are to (1) establish protocols for improved sensitivity of low-level corticosteroids ( aldosterone and

  9. Stress Hormones and their Regulation in a Captive Dolphin Population

    DTIC Science & Technology

    2015-09-30

    dorian.houser@nmmf.org Award Number: N000141310770 http://www.nmmf.org/ physiology --ecology.html LONG-TERM GOALS The Navy requires an understanding...establish protocols for improved sensitivity of low-level corticosteroids (cortisol and aldosterone ) frequenctly observed in cetaceans; (2) determine the...assessing baseline variability in stress hormones and 2) evaluating physiological and metabolic alterations that occur during stress. This grant

  10. Development of the Diabetes Technology Society Blood Glucose Monitor System Surveillance Protocol

    PubMed Central

    Klonoff, David C.; Lias, Courtney; Beck, Stayce; Parkes, Joan Lee; Kovatchev, Boris; Vigersky, Robert A.; Arreaza-Rubin, Guillermo; Burk, Robert D.; Kowalski, Aaron; Little, Randie; Nichols, James; Petersen, Matt; Rawlings, Kelly; Sacks, David B.; Sampson, Eric; Scott, Steve; Seley, Jane Jeffrie; Slingerland, Robbert; Vesper, Hubert W.

    2015-01-01

    Background: Inaccurate blood glucsoe monitoring systems (BGMSs) can lead to adverse health effects. The Diabetes Technology Society (DTS) Surveillance Program for cleared BGMSs is intended to protect people with diabetes from inaccurate, unreliable BGMS products that are currently on the market in the United States. The Surveillance Program will provide an independent assessment of the analytical performance of cleared BGMSs. Methods: The DTS BGMS Surveillance Program Steering Committee included experts in glucose monitoring, surveillance testing, and regulatory science. Over one year, the committee engaged in meetings and teleconferences aiming to describe how to conduct BGMS surveillance studies in a scientifically sound manner that is in compliance with good clinical practice and all relevant regulations. Results: A clinical surveillance protocol was created that contains performance targets and analytical accuracy-testing studies with marketed BGMS products conducted by qualified clinical and laboratory sites. This protocol entitled “Protocol for the Diabetes Technology Society Blood Glucose Monitor System Surveillance Program” is attached as supplementary material. Conclusion: This program is needed because currently once a BGMS product has been cleared for use by the FDA, no systematic postmarket Surveillance Program exists that can monitor analytical performance and detect potential problems. This protocol will allow identification of inaccurate and unreliable BGMSs currently available on the US market. The DTS Surveillance Program will provide BGMS manufacturers a benchmark to understand the postmarket analytical performance of their products. Furthermore, patients, health care professionals, payers, and regulatory agencies will be able to use the results of the study to make informed decisions to, respectively, select, prescribe, finance, and regulate BGMSs on the market. PMID:26481642

  11. Development of the Diabetes Technology Society Blood Glucose Monitor System Surveillance Protocol.

    PubMed

    Klonoff, David C; Lias, Courtney; Beck, Stayce; Parkes, Joan Lee; Kovatchev, Boris; Vigersky, Robert A; Arreaza-Rubin, Guillermo; Burk, Robert D; Kowalski, Aaron; Little, Randie; Nichols, James; Petersen, Matt; Rawlings, Kelly; Sacks, David B; Sampson, Eric; Scott, Steve; Seley, Jane Jeffrie; Slingerland, Robbert; Vesper, Hubert W

    2016-05-01

    Inaccurate blood glucsoe monitoring systems (BGMSs) can lead to adverse health effects. The Diabetes Technology Society (DTS) Surveillance Program for cleared BGMSs is intended to protect people with diabetes from inaccurate, unreliable BGMS products that are currently on the market in the United States. The Surveillance Program will provide an independent assessment of the analytical performance of cleared BGMSs. The DTS BGMS Surveillance Program Steering Committee included experts in glucose monitoring, surveillance testing, and regulatory science. Over one year, the committee engaged in meetings and teleconferences aiming to describe how to conduct BGMS surveillance studies in a scientifically sound manner that is in compliance with good clinical practice and all relevant regulations. A clinical surveillance protocol was created that contains performance targets and analytical accuracy-testing studies with marketed BGMS products conducted by qualified clinical and laboratory sites. This protocol entitled "Protocol for the Diabetes Technology Society Blood Glucose Monitor System Surveillance Program" is attached as supplementary material. This program is needed because currently once a BGMS product has been cleared for use by the FDA, no systematic postmarket Surveillance Program exists that can monitor analytical performance and detect potential problems. This protocol will allow identification of inaccurate and unreliable BGMSs currently available on the US market. The DTS Surveillance Program will provide BGMS manufacturers a benchmark to understand the postmarket analytical performance of their products. Furthermore, patients, health care professionals, payers, and regulatory agencies will be able to use the results of the study to make informed decisions to, respectively, select, prescribe, finance, and regulate BGMSs on the market. © 2015 Diabetes Technology Society.

  12. TH-E-209-01: Fluoroscopic Dose Monitoring and Patient Follow-Up Program at Massachusetts General Hospital

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liu, B.

    2016-06-15

    Radiation dose monitoring solutions have opened up new opportunities for medical physicists to be more involved in modern clinical radiology practices. In particular, with the help of comprehensive radiation dose data, data-driven protocol management and informed case follow up are now feasible. Significant challenges remain however and the problems faced by medical physicists are highly heterogeneous. Imaging systems from multiple vendors and a wide range of vintages co-exist in the same department and employ data communication protocols that are not fully standardized or implemented making harmonization complex. Many different solutions for radiation dose monitoring have been implemented by imaging facilitiesmore » over the past few years. Such systems are based on commercial software, home-grown IT solutions, manual PACS data dumping, etc., and diverse pathways can be used to bring the data to impact clinical practice. The speakers will share their experiences with creating or tailoring radiation dose monitoring/management systems and procedures over the past few years, which vary significantly in design and scope. Topics to cover: (1) fluoroscopic dose monitoring and high radiation event handling from a large academic hospital; (2) dose monitoring and protocol optimization in pediatric radiology; and (3) development of a home-grown IT solution and dose data analysis framework. Learning Objectives: Describe the scope and range of radiation dose monitoring and protocol management in a modern radiology practice Review examples of data available from a variety of systems and how it managed and conveyed. Reflect on the role of the physicist in radiation dose awareness.« less

  13. Telemetry methods for monitoring physiological parameters

    NASA Technical Reports Server (NTRS)

    Fryer, T. B.; Sandler, H.

    1982-01-01

    The use of telemetry to monitor various physiological functions is discussed. The advantages of the technique and the parameters that it can monitor are assessed, and the main telemetry systems, including pressure telemetry, flow telemetry, and multichannel telemetry, are detailed. Human applications of implanted flow transducers, total implant versus backpack telemetry, the use of power sources and integrated circuits in telemetry, and the future prospects of the technique in hypertension treatment and research are discussed.

  14. Activity monitoring reflects cardiovascular and metabolic variations in COPD patients across GOLD stages II to IV.

    PubMed

    Kortianou, E A; Louvaris, Z; Vasilopoulou, M; Nasis, I; Kaltsakas, G; Koulouris, N G; Vogiatzis, I

    2013-12-01

    We investigated whether activity monitoring reliably reflects variations in oxygen transport and utilization during walking in COPD patients. Forty-two patients (14 in each GOLD stage II, III and IV) performed an incremental treadmill protocol to the limit of tolerance. Breath-by-breath gas exchange, central hemodynamic variables and activity monitoring were simultaneously recorded. Physiological variables and accelerometer outputs rose linearly with walking speeds. Strong correlations (r[interquartile range, IQR]) were found between treadmill walking intensity (WI: range 0.8-2.0 ms(-2)) and oxygen consumption (0.95 [IQR 0.87-0.97]), (range 7.6-15.5 ml kg(-1)min(-1)); minute ventilation (0.95 [IQR 0.86-0.98]), (range 20-37 l min(-1)); cardiac output (0.89 [IQR 0.73-0.94]), (range 6.8-11.5 l min(-1)) and arteriovenous oxygen concentration difference (0.84 [IQR 0.76-0.90]), (range 7.7-12.1 ml O2100 ml(-1)). Correlations between WI and gas exchange or central hemodynamic parameters were not different across GOLD stages. In conclusion, central hemodynamic, respiratory and muscle metabolic variations during incremental treadmill exercise are tightly associated to changes in walking intensity as recorded by accelerometry across GOLD stages II to IV. Interestingly, the magnitude of these associations is not different across GOLD stages. Copyright © 2013 Elsevier B.V. All rights reserved.

  15. Estimation of network path segment delays

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nichols, Kathleen Marie

    A method for estimation of a network path segment delay includes determining a scaled time stamp for each packet of a plurality of packets by scaling a time stamp for each respective packet to minimize a difference of at least one of a frequency and a frequency drift between a transport protocol clock of a host and a monitoring point. The time stamp for each packet is provided by the transport protocol clock of the host. A corrected time stamp for each packet is determined by removing from the scaled time stamp for each respective packet, a temporal offset betweenmore » the transport protocol clock and the monitoring clock by minimizing a temporal delay variation of the plurality of packets traversing a segment between the host and the monitoring point.« less

  16. Performance Analysis of Surfing: A Review.

    PubMed

    Farley, Oliver R L; Abbiss, Chris R; Sheppard, Jeremy M

    2017-01-01

    Farley, ORL, Abbiss, CR, and Sheppard, JM. Performance Analysis of Surfing: A Review. J Strength Cond Res 31(1): 260-271, 2017-Despite the increased professionalism and substantial growth of surfing worldwide, there is limited information available to practitioners and coaches in terms of key performance analytics that are common in other field-based sports. Indeed, research analyzing surfing performance is limited to a few studies examining male surfers' heart rates, surfing activities through time-motion analysis (TMA) using video recordings and Global Positioning Satellite (GPS) data during competition and recreational surfing. These studies have indicated that specific activities undertaken during surfing are unique with a variety of activities (i.e., paddling, resting, wave riding, breath holding, and recovery of surfboard in the surf). Furthermore, environmental and wave conditions also seem to influence the physical demands of competition surfing. It is due to these demands that surfers are required to have a high cardiorespiratory fitness, high muscular endurance, and considerable strength and anaerobic power, particular within the upper torso. By exploring various methods of performance analysis used within other sports, it is possible to improve our understanding of surfing demands. In so doing this will assist in the development of protocols and strategies to assess physiological characteristics of surfers, monitor athlete performance, improve training prescription, and identify talent. Therefore, this review explores the current literature to provide insights into methodological protocols, delimitations of research into athlete analysis and an overview of surfing dynamics. Specifically, this review will describe and review the use of TMA, GPS, and other technologies (i.e., HR) that are used in external and internal load monitoring as they pertain to surfing.

  17. Treatment of antipsychotic-associated obesity with a GLP-1 receptor agonist--protocol for an investigator-initiated prospective, randomised, placebo-controlled, double-blinded intervention study: the TAO study protocol.

    PubMed

    Ishøy, Pelle L; Knop, Filip K; Broberg, Brian V; Baandrup, Lone; Fagerlund, Birgitte; Jørgensen, Niklas R; Andersen, Ulrik B; Rostrup, Egill; Glenthøj, Birte Y; Ebdrup, Bjørn H

    2014-01-08

    Antipsychotic medication is widely associated with dysmetabolism including obesity and type 2 diabetes, cardiovascular-related diseases and early death. Obesity is considered the single most important risk factor for cardiovascular morbidity and mortality. Interventions against antipsychotic-associated obesity are limited and insufficient. Glucagon-like peptide-1 (GLP-1) receptor agonists are approved for the treatment of type 2 diabetes, but their bodyweight-lowering effects have also been recognised in patients with non-diabetes. The primary endpoint of this trial is weight loss after 3 months of treatment with a GLP-1 receptor agonist (exenatide once weekly) in patients with non-diabetic schizophrenia with antipsychotic-associated obesity. Secondary endpoints include physiological and metabolic measurements, various psychopathological and cognitive measures, and structural and functional brain MRI. 40 obese patients with schizophrenia or schizoaffective disorder treated with antipsychotic drugs will be randomised to subcutaneous injection of exenatide once weekly (2 mg) or placebo for 3 months, adjunctive to their antipsychotic treatment. The trial has been approved by the Danish Health and Medicines Authority, the National Committee on Health Research Ethics and the Danish Data Protection Agency. Trial participation presupposes theoral and written patient informed consent. An external, independent monitoring committee (Good Clinical Practice Unit at Copenhagen University Hospital) will monitor the study according to the GCP Guidelines. Trial data, including positive, negative and inconclusive results, will be presented at national and international scientific meetings and conferences. Papers will be submitted to peer-reviewed journals. ClinicalTrials.gov identifier: NCT01794429; National Committee on Health Research Ethics project number: 36378; EudraCT nr: 2012-005404-17; The Danish Data Protection Agency project number: RHP-2012-027.

  18. Specifications Physiological Monitoring System

    NASA Technical Reports Server (NTRS)

    1985-01-01

    The operation of a physiological monitoring system (PMS) is described. Specifications were established for performance, design, interface, and test requirements. The PMS is a compact, microprocessor-based system, which can be worn in a pack on the body or may be mounted on a Spacelab rack or other appropriate structure. It consists of two modules, the Data Control Unit (DCU) and the Remote Control/Display Unit (RCDU). Its purpose is to collect and distribute data from physiological experiments in the Spacelab and in the Orbiter.

  19. Novel use of a noninvasive hemodynamic monitor in a personalized, active learning simulation.

    PubMed

    Zoller, Jonathan K; He, Jianghua; Ballew, Angela T; Orr, Walter N; Flynn, Brigid C

    2017-06-01

    The present study furthered the concept of simulation-based medical education by applying a personalized active learning component. We tested this novel approach utilizing a noninvasive hemodynamic monitor with the capability to measure and display in real time numerous hemodynamic parameters in the exercising participant. Changes in medical knowledge concerning physiology were examined with a pre-and posttest. Simply by observation of one's own hemodynamic variables, the understanding of complex physiological concepts was significantly enhanced. Copyright © 2017 the American Physiological Society.

  20. Theoretical analysis of the mechanisms of a gender differentiation in the propensity for orthostatic intolerance after spaceflight

    PubMed Central

    2010-01-01

    Background A tendency to develop reentry orthostasis after a prolonged exposure to microgravity is a common problem among astronauts. The problem is 5 times more prevalent in female astronauts as compared to their male counterparts. The mechanisms responsible for this gender differentiation are poorly understood despite many detailed and complex investigations directed toward an analysis of the physiologic control systems involved. Methods In this study, a series of computer simulation studies using a mathematical model of cardiovascular functioning were performed to examine the proposed hypothesis that this phenomenon could be explained by basic physical forces acting through the simple common anatomic differences between men and women. In the computer simulations, the circulatory components and hydrostatic gradients of the model were allowed to adapt to the physical constraints of microgravity. After a simulated period of one month, the model was returned to the conditions of earth's gravity and the standard postflight tilt test protocol was performed while the model output depicting the typical vital signs was monitored. Conclusions The analysis demonstrated that a 15% lowering of the longitudinal center of gravity in the anatomic structure of the model was all that was necessary to prevent the physiologic compensatory mechanisms from overcoming the propensity for reentry orthostasis leading to syncope. PMID:20298577

  1. Validation of the fully automated A&D TM-2656 blood pressure monitor according to the British Hypertension Society Protocol.

    PubMed

    Zeng, Wei-Fang; Liu, Ming; Kang, Yuan-Yuan; Li, Yan; Wang, Ji-Guang

    2013-08-01

    The present study aimed to evaluate the accuracy of the fully automated oscillometric upper-arm blood pressure monitor TM-2656 according to the British Hypertension Society (BHS) Protocol 1993. We recruited individuals until there were 85 eligible participants and their blood pressure could meet the blood pressure distribution requirements specified by the BHS Protocol. For each individual, we sequentially measured the systolic and diastolic blood pressures using a mercury sphygmomanometer (two observers) and the TM-2656 device (one supervisor). Data analysis was carried out according to the BHS Protocol. The device achieved grade A. The percentage of blood pressure differences within 5, 10, and 15 mmHg was 62, 85, and 96%, respectively, for systolic blood pressure, and 71, 93, and 99%, respectively, for diastolic blood pressure. The average (±SD) of the device-observer differences was -2.1±7.8 mmHg (P<0.0001) and -1.1±5.8 mmHg (P<0.0001) for systolic and diastolic blood pressures, respectively. The A&D upper-arm blood pressure monitor TM-2656 has passed the requirements of the BHS Protocol, and can thus be recommended for blood pressure measurement.

  2. HomeADL for adaptive ADL monitoring within smart homes.

    PubMed

    Hong, Xin; Nugent, Chris D; Finlay, Dewar D; Mulvenna, Maurice

    2008-01-01

    In this paper we present homeADL: a representation standard for an inference hierarchy of activities of daily living which may be monitored in a sensor equipped smart home. The approach allows a free exchange of ADL monitoring structures between different communities who share the same concern of providing high quality healthcare to the elderly. Its ability of matching different ADL protocols enables a mapping between an ADL protocol to a suitable smart home which makes an effective management of smart homes within a community hence, not only being able to satisfy an individual's healthcare requirements but also efficiently using monitoring resources at hand.

  3. Optimal Adenosine Stress for Maximum Stress Perfusion, Coronary Flow Reserve, and Pixel Distribution of Coronary Flow Capacity by Kolmogorov-Smirnov Analysis.

    PubMed

    Kitkungvan, Danai; Lai, Dejian; Zhu, Hongjian; Roby, Amanda E; Johnson, Nils P; Steptoe, Derek D; Patel, Monica B; Kirkeeide, Richard; Gould, K Lance

    2017-02-01

    Different adenosine stress imaging protocols have not been systemically validated for absolute myocardial perfusion and coronary flow reserve (CFR) by positron emission tomography, where submaximal stress precludes assessing physiological severity of coronary artery disease. In 127 volunteers, serial rest-stress positron emission tomography scans using rubidium-82 with various adenosine infusion protocols identified (1) the protocol with maximum stress perfusion and CFR, (2) test-retest precision in same subject, (3) stress perfusion and CFR after adenosine compared with dipyridamole, (4) heterogeneity of coronary flow capacity combining stress perfusion and CFR, and (5) potential relevance for patients with risk factors or coronary artery disease. The adenosine 6-minute infusion with rubidium-82 injection at 3 minutes caused CFR that was significantly 15.7% higher than the 4-minute adenosine infusion with rubidium-82 injection at 2 minutes and significantly more homogeneous by Kolmogorov-Smirnov analysis for histograms of 1344 pixel range of perfusion in paired positron emission tomographies. In a coronary artery disease cohort separate from volunteers of this study, compared with the 3/6-minute protocol, the 2/4-minute adenosine protocol would potentially have changed 332 of 1732 (19%) positron emission tomographies at low-risk physiological severity CFR ≥2.3 to CFR <2.0, thereby implying high-risk quantitative severity potentially appropriate for interventions but because of suboptimal stress of the 2/4 protocol in some patients. The 6-minute adenosine infusion with rubidium-82 activation at 3 minutes produced CFR that averaged 15.7% higher than that in the 2/4-minute protocol, thereby potentially providing essential information for personalized management in some patients. © 2017 American Heart Association, Inc.

  4. Extracting aerobic system dynamics during unsupervised activities of daily living using wearable sensor machine learning models.

    PubMed

    Beltrame, Thomas; Amelard, Robert; Wong, Alexander; Hughson, Richard L

    2018-02-01

    Physical activity levels are related through algorithms to the energetic demand, with no information regarding the integrity of the multiple physiological systems involved in the energetic supply. Longitudinal analysis of the oxygen uptake (V̇o 2 ) by wearable sensors in realistic settings might permit development of a practical tool for the study of the longitudinal aerobic system dynamics (i.e., V̇o 2 kinetics). This study evaluated aerobic system dynamics based on predicted V̇o 2 data obtained from wearable sensors during unsupervised activities of daily living (μADL). Thirteen healthy men performed a laboratory-controlled moderate exercise protocol and were monitored for ≈6 h/day for 4 days (μADL data). Variables derived from hip accelerometer (ACC HIP ), heart rate monitor, and respiratory bands during μADL were extracted and processed by a validated random forest regression model to predict V̇o 2 . The aerobic system analysis was based on the frequency-domain analysis of ACC HIP and predicted V̇o 2 data obtained during μADL. Optimal samples for frequency domain analysis (constrained to ≤0.01 Hz) were selected when ACC HIP was higher than 0.05 g at a given frequency (i.e., participants were active). The temporal characteristics of predicted V̇o 2 data during μADL correlated with the temporal characteristics of measured V̇o 2 data during laboratory-controlled protocol ([Formula: see text] = 0.82, P < 0.001, n = 13). In conclusion, aerobic system dynamics can be investigated during unsupervised activities of daily living by wearable sensors. Although speculative, these algorithms have the potential to be incorporated into wearable systems for early detection of changes in health status in realistic environments by detecting changes in aerobic response dynamics. NEW & NOTEWORTHY The early detection of subclinical aerobic system impairments might be indicative of impaired physiological reserves that impact the capacity for physical activity. This study is the first to use wearable sensors in unsupervised activities of daily living in combination with novel machine learning algorithms to investigate the aerobic system dynamics with the potential to contribute to models of functional health status and guide future individualized health care in the normal population.

  5. A design of wireless sensor networks for a power quality monitoring system.

    PubMed

    Lim, Yujin; Kim, Hak-Man; Kang, Sanggil

    2010-01-01

    Power grids deal with the business of generation, transmission, and distribution of electric power. Recently, interest in power quality in electrical distribution systems has increased rapidly. In Korea, the communication network to deliver voltage, current, and temperature measurements gathered from pole transformers to remote monitoring centers employs cellular mobile technology. Due to high cost of the cellular mobile technology, power quality monitoring measurements are limited and data gathering intervals are large. This causes difficulties in providing the power quality monitoring service. To alleviate the problems, in this paper we present a communication infrastructure to provide low cost, reliable data delivery. The communication infrastructure consists of wired connections between substations and monitoring centers, and wireless connections between pole transformers and substations. For the wireless connection, we employ a wireless sensor network and design its corresponding data forwarding protocol to improve the quality of data delivery. For the design, we adopt a tree-based data forwarding protocol in order to customize the distribution pattern of the power quality information. We verify the performance of the proposed data forwarding protocol quantitatively using the NS-2 network simulator.

  6. Ebola virus disease in a humanitarian aid worker - New York City, October 2014.

    PubMed

    Yacisin, Kari; Balter, Sharon; Fine, Annie; Weiss, Don; Ackelsberg, Joel; Prezant, David; Wilson, Ross; Starr, David; Rakeman, Jennifer; Raphael, Marisa; Quinn, Celia; Toprani, Amita; Clark, Nancy; Link, Nathan; Daskalakis, Demetre; Maybank, Aletha; Layton, Marcelle; Varma, Jay K

    2015-04-03

    In late October 2014, Ebola virus disease (Ebola) was diagnosed in a humanitarian aid worker who recently returned from West Africa to New York City (NYC). The NYC Department of Health and Mental Hygiene (DOHMH) actively monitored three close contacts of the patient and 114 health care personnel. No secondary cases of Ebola were detected. In collaboration with local and state partners, DOHMH had developed protocols to respond to such an event beginning in July 2014. These protocols included safely transporting a person at the first report of symptoms to a local hospital prepared to treat a patient with Ebola, laboratory testing for Ebola, and monitoring of contacts. In response to this single case of Ebola, initial health care worker active monitoring protocols needed modification to improve clarity about what types of exposure should be monitored. The response costs were high in both human resources and money: DOHMH alone spent $4.3 million. However, preparedness activities that include planning and practice in effectively monitoring the health of workers involved in Ebola patient care can help prevent transmission of Ebola.

  7. Network Monitor and Control of Disruption-Tolerant Networks

    NASA Technical Reports Server (NTRS)

    Torgerson, J. Leigh

    2014-01-01

    For nearly a decade, NASA and many researchers in the international community have been developing Internet-like protocols that allow for automated network operations in networks where the individual links between nodes are only sporadically connected. A family of Disruption-Tolerant Networking (DTN) protocols has been developed, and many are reaching CCSDS Blue Book status. A NASA version of DTN known as the Interplanetary Overlay Network (ION) has been flight-tested on the EPOXI spacecraft and ION is currently being tested on the International Space Station. Experience has shown that in order for a DTN service-provider to set up a large scale multi-node network, a number of network monitor and control technologies need to be fielded as well as the basic DTN protocols. The NASA DTN program is developing a standardized means of querying a DTN node to ascertain its operational status, known as the DTN Management Protocol (DTNMP), and the program has developed some prototypes of DTNMP software. While DTNMP is a necessary component, it is not sufficient to accomplish Network Monitor and Control of a DTN network. JPL is developing a suite of tools that provide for network visualization, performance monitoring and ION node control software. This suite of network monitor and control tools complements the GSFC and APL-developed DTN MP software, and the combined package can form the basis for flight operations using DTN.

  8. The effect of functional electrical stimulation on the physiological cost of gait in people with multiple sclerosis.

    PubMed

    Paul, L; Rafferty, D; Young, S; Miller, L; Mattison, P; McFadyen, A

    2008-08-01

    Functional electrical stimulation (FES) is used clinically in the management of drop foot in people suffering from neurological conditions. The aim of the study was to investigate the effects of FES, in terms of speed and physiological cost of gait, in people with multiple sclerosis (pwMS). Twelve pwMS and 12 healthy matched controls walked at their own preferred walking speed (PWS) for 5 min around a 10 m elliptical course. Subjects with MS completed the protocol with and without using their FES. In addition, control subjects completed the protocol twice more walking at the same PWS of the pwMS to which they were matched. Wearing FES lead to a significant improvement in walking speed (0.49 ms(-1) and 0.43 ms(-1) with and without their FES respectively; P<0.001) and a significant reduction in the physiological cost of gait (0.41 mL min(-1) kg(-1) m(-1) and 0.46 mL min(-1) kg(-1) m(-1) with and without FES respectively; P=0.017) in pwMS. The speed of walking, oxygen uptake, and physiological cost were significantly different between pwMS and controls both at preferred and matched speeds. Although pwMS exhibit a higher physiological cost of walking, FES offers an orthotic benefit to pwMS and should be considered as a possible treatment option.

  9. Validation of the Pangao PG-800B26 upper arm blood pressure monitor in the general population according to the European Society of Hypertension and the British Hypertension Society protocols.

    PubMed

    Chen, Liang; Li, Jiyu; Wen, Jing; Guo, Changfeng; Zhang, Jingying; Yu, Zhen

    2018-02-01

    This study aimed to evaluate the accuracy of the automated oscillometric upper arm blood pressure monitor Pangao PG-800B26 for home blood pressure monitoring according to the European Society of Hypertension International Protocol (ESH-IP) revision 2010 and the British Hypertension Society (BHS) protocols. Systolic and diastolic blood pressures were measured sequentially in 33 and 85 adults, respectively, on the basis of the ESH-IP and BHS protocols using a mercury sphygmomanometer (two observers) and the device (one supervisor). The procedures and analysis methods of the protocols were followed precisely. The device fulfilled the criteria of the ESH-IP, with device-observer differences of 1.01±5.16 and -0.58±4.17 mmHg for systolic and diastolic blood pressure, respectively. Furthermore, the A/A grade of the BHS protocol was also achieved for overall grading and for the three pressure levels, with average differences of 0.85±6.35 and -0.15±5.65 mmHg for systolic and diastolic blood pressure, respectively, which also fulfilled the requirements of the Association for the Advancement of Medical Instrumentation. The Pangao PG-800B26 fulfilled the criteria of the ESH-IP 2010 and achieved the A/A grade of the BHS protocol, and hence can be recommended for home use in adults.

  10. Recent advancement in biosensors technology for animal and livestock health management.

    PubMed

    Neethirajan, Suresh; Tuteja, Satish K; Huang, Sheng-Tung; Kelton, David

    2017-12-15

    The term biosensors encompasses devices that have the potential to quantify physiological, immunological and behavioural responses of livestock and multiple animal species. Novel biosensing methodologies offer highly specialised monitoring devices for the specific measurement of individual and multiple parameters covering an animal's physiology as well as monitoring of an animal's environment. These devices are not only highly specific and sensitive for the parameters being analysed, but they are also reliable and easy to use, and can accelerate the monitoring process. Novel biosensors in livestock management provide significant benefits and applications in disease detection and isolation, health monitoring and detection of reproductive cycles, as well as monitoring physiological wellbeing of the animal via analysis of the animal's environment. With the development of integrated systems and the Internet of Things, the continuously monitoring devices are expected to become affordable. The data generated from integrated livestock monitoring is anticipated to assist farmers and the agricultural industry to improve animal productivity in the future. The data is expected to reduce the impact of the livestock industry on the environment, while at the same time driving the new wave towards the improvements of viable farming techniques. This review focusses on the emerging technological advancements in monitoring of livestock health for detailed, precise information on productivity, as well as physiology and well-being. Biosensors will contribute to the 4th revolution in agriculture by incorporating innovative technologies into cost-effective diagnostic methods that can mitigate the potentially catastrophic effects of infectious outbreaks in farmed animals. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. The singer's voice range profile: female professional opera soloists.

    PubMed

    Lamarche, Anick; Ternström, Sten; Pabon, Peter

    2010-07-01

    This work concerns the collection of 30 voice range profiles (VRPs) of female operatic voice. We address the questions: Is there a need for a singer's protocol in VRP acquisition? Are physiological measurements sufficient or should the measurement of performance capabilities also be included? Can we address the female singing voice in general or is there a case for categorizing voices when studying phonetographic data? Subjects performed a series of structured tasks involving both standard speech voice protocols and additional singing tasks. Singers also completed an extensive questionnaire. Physiological VRPs differ from performance VRPs. Two new VRP metrics, the voice area above a defined level threshold and the dynamic range independent from the fundamental frequency (F(0)), were found to be useful in the analysis of singer VRPs. Task design had no effect on performance VRP outcomes. Voice category differences were mainly attributable to phonation frequency-based information. Results support the clinical importance of addressing the vocal instrument as it is used in performance. Equally important is the elaboration of a protocol suitable for the singing voice. The given context and instructions can be more important than task design for performance VRPs. Yet, for physiological VRP recordings, task design remains critical. Both types of VRPs are suggested for a singer's voice evaluation. Copyright (c) 2010 The Voice Foundation. Published by Mosby, Inc. All rights reserved.

  12. A survey on temperature-aware routing protocols in wireless body sensor networks.

    PubMed

    Oey, Christian Henry Wijaya; Moh, Sangman

    2013-08-02

    The rapid growth of the elderly population in the world and the rising cost of healthcare impose big issues for healthcare and medical monitoring. A Wireless Body Sensor Network (WBSN) is comprised of small sensor nodes attached inside, on or around a human body, the main purpose of which is to monitor the functions and surroundings of the human body. However, the heat generated by the node's circuitry and antenna could cause damage to the human tissue. Therefore, in designing a routing protocol for WBSNs, it is important to reduce the heat by incorporating temperature into the routing metric. The main contribution of this paper is to survey existing temperature-aware routing protocols that have been proposed for WBSNs. In this paper, we present a brief overview of WBSNs, review the existing routing protocols comparatively and discuss challenging open issues in the design of routing protocols.

  13. A Survey on Temperature-Aware Routing Protocols in Wireless Body Sensor Networks

    PubMed Central

    Oey, Christian Henry Wijaya; Moh, Sangman

    2013-01-01

    The rapid growth of the elderly population in the world and the rising cost of healthcare impose big issues for healthcare and medical monitoring. A Wireless Body Sensor Network (WBSN) is comprised of small sensor nodes attached inside, on or around a human body, the main purpose of which is to monitor the functions and surroundings of the human body. However, the heat generated by the node's circuitry and antenna could cause damage to the human tissue. Therefore, in designing a routing protocol for WBSNs, it is important to reduce the heat by incorporating temperature into the routing metric. The main contribution of this paper is to survey existing temperature-aware routing protocols that have been proposed for WBSNs. In this paper, we present a brief overview of WBSNs, review the existing routing protocols comparatively and discuss challenging open issues in the design of routing protocols. PMID:23917259

  14. Menopausal Hot Flashes and White Matter Hyperintensities

    PubMed Central

    Thurston, Rebecca C.; Aizenstein, Howard J.; Derby, Carol A.; Sejdić, Ervin; Maki, Pauline M.

    2015-01-01

    Objective Hot flashes are the classic menopausal symptom. Emerging data links hot flashes to cardiovascular disease (CVD) risk, yet how hot flashes are related to brain health is poorly understood. We examined the relationship between hot flashes - measured via physiologic monitor and self-report - and white matter hyperintensities (WMH) among midlife women. Methods Twenty midlife women ages 40-60 without clinical CVD, with their uterus and both ovaries, and not taking hormone therapy were recruited. Women underwent 24 hours of ambulatory physiologic and diary hot flash monitoring to quantify hot flashes; magnetic resonance imaging to assess WMH burden; 72 hours of actigraphy and questionnaires to quantify sleep; and a blood draw, questionnaires, and physical measures to quantify demographics and CVD risk factors. Test of a priori hypotheses regarding relations between physiologically-monitored and self-reported wake and sleep hot flashes and WMH were conducted in linear regression models. Results More physiologically-monitored hot flashes during sleep were associated with greater WMH, controlling for age, race, and body mass index [beta(standard error)=.0002 (.0001), p=.03]. Findings persisted controlling for sleep characteristics and additional CVD risk factors. No relations were observed for self-reported hot flashes. Conclusions More physiologically-monitored hot flashes during sleep were associated with greater WMH burden among midlife women free of clinical CVD. Results suggest that relations between hot flashes and CVD risk observed in the periphery may extend to the brain. Future work should consider the unique role of sleep hot flashes in brain health. PMID:26057822

  15. Protocol and Demonstrations of Probabilistic Reliability Assessment for Structural Health Monitoring Systems (Preprint)

    DTIC Science & Technology

    2011-11-01

    assessment to quality of localization/characterization estimates. This protocol includes four critical components: (1) a procedure to identify the...critical factors impacting SHM system performance; (2) a multistage or hierarchical approach to SHM system validation; (3) a model -assisted evaluation...Lindgren, E. A ., Buynak, C. F., Steffes, G., Derriso, M., “ Model -assisted Probabilistic Reliability Assessment for Structural Health Monitoring

  16. Best Management Practices (BMP) Monitoring Manual Field Guide: Implementation and Effectiveness for Protection of Water Resources

    Treesearch

    David Welsch; Roger Ryder; Tim Post

    2006-01-01

    The specific purpose of the BMP protocol is to create an economical, standardized, and repeatable BMP monitoring process that is completely automated, from data gathering through report generation, in order to provide measured data, ease of use, and compatibility with State BMP programs.The protocol was developed to meet the following needs:? Document the use and...

  17. The Functional Task Test: Results from the One-Year Mission

    NASA Technical Reports Server (NTRS)

    Bloomberg, J. J; Batson, C. D.; Buxton, R. E.; Feiveson, A. H.; Kofman, I. S.; Laurie, S.; Lee, S. M. C.; Miller, C. A.; Mulavara, A. P.; Peters, B. T.; hide

    2017-01-01

    Exposure to the microgravity conditions of spaceflight causes astronauts to experience alterations in multiple physiological systems including sensorimotor disturbances, cardiovascular deconditioning, and loss of muscle mass and strength. Some or all of these changes might affect the ability of crewmembers to perform critical mission tasks immediately after landing on a planetary surface. The goal of our recently completed Functional Task Test (FTT) study was to determine the effects of spaceflight on functional tests that are representative of high priority exploration mission tasks and to identify the key underlying physiological factors that contribute to decrements in performance. The FTT is comprised of seven functional tests and a corresponding set of interdisciplinary physiological measures specifically targeting the sensorimotor, cardiovascular and muscular changes associated with exposure to spaceflight. Both Shuttle and International Space Station (ISS) astronauts were tested before and after spaceflight. Additionally, we conducted a supporting study in which subjects performed the FTT protocol before and after 70 days of 6 deg head-down bed rest, an analog for spaceflight. Two groups of bed rest subjects were studied: one group who performed aerobic and resistive exercise during bed rest using protocols similar to astronauts and one group who served as non-exercise controls. The bed rest analog allowed us to isolate the impact of body unloading without other spaceflight environmental factors on both functional tasks and on the underlying physiological factors that lead to decrements in performance, and then to compare those results with the results obtained in our spaceflight study. As an extension to the FTT study we collected data from one ISS crewmember who experienced 340 days in space using the same FTT protocol used previously to test spaceflight and bed rest subjects. Data were collected three times preflight and 1.7, 7.5 and 36.5 days after landing. The FTT one-year results will be presented at the meeting, and a comparison will be made with data previously obtained using the same protocol on astronauts tested before and after 6 months in space. Future work will focus on collecting data from additional subjects from one-year flights to gain a better assessment of extreme long-duration exposure to spaceflight on both functional measure of performance and physiological metrics.

  18. Monitoring well utility in a heterogeneous DNAPL source zone area: Insights from proximal multilevel sampler wells and sampling capture-zone modelling.

    PubMed

    McMillan, Lindsay A; Rivett, Michael O; Wealthall, Gary P; Zeeb, Peter; Dumble, Peter

    2018-03-01

    Groundwater-quality assessment at contaminated sites often involves the use of short-screen (1.5 to 3 m) monitoring wells. However, even over these intervals considerable variation may occur in contaminant concentrations in groundwater adjacent to the well screen. This is especially true in heterogeneous dense non-aqueous phase liquid (DNAPL) source zones, where cm-scale contamination variability may call into question the effectiveness of monitoring wells to deliver representative data. The utility of monitoring wells in such settings is evaluated by reference to high-resolution multilevel sampler (MLS) wells located proximally to short-screen wells, together with sampling capture-zone modelling to explore controls upon well sample provenance and sensitivity to monitoring protocols. Field data are analysed from the highly instrumented SABRE research site that contained an old trichloroethene source zone within a shallow alluvial aquifer at a UK industrial facility. With increased purging, monitoring-well samples tend to a flow-weighted average concentration but may exhibit sensitivity to the implemented protocol and degree of purging. Formation heterogeneity adjacent to the well-screen particularly, alongside pump-intake position and water level, influence this sensitivity. Purging of low volumes is vulnerable to poor reproducibility arising from concentration variability predicted over the initial 1 to 2 screen volumes purged. Marked heterogeneity may also result in limited long-term sample concentration stabilization. Development of bespoke monitoring protocols, that consider screen volumes purged, alongside water-quality indicator parameter stabilization, is recommended to validate and reduce uncertainty when interpreting monitoring-well data within source zone areas. Generalised recommendations on monitoring well based protocols are also developed. A key monitoring well utility is their proportionately greater sample draw from permeable horizons constituting a significant contaminant flux pathway and hence representative fraction of source mass flux. Acquisition of complementary, high-resolution, site monitoring data, however, vitally underpins optimal interpretation of monitoring-well datasets and appropriate advancement of a site conceptual model and remedial implementation. Copyright © 2018 The Authors. Published by Elsevier B.V. All rights reserved.

  19. Development of a new clot formation protocol for standardized in vitro investigations of sonothrombolysis.

    PubMed

    Roessler, Florian C; Teichert, Andrea; Ohlrich, Marcus; Marxsen, Jan H; Stellmacher, Florian; Tanislav, Christian; Seidel, Günter

    2014-11-30

    Agreement about the most suitable clot formation protocol for sonothrombolysis investigations is lacking. Lysis rates vary strongly owing to different test conditions and, thus, cannot be compared. We aim to establish a simple but physiologically grounded protocol for in vitro coagulation to enable standardized sonothrombolysis investigations. Clots were generated from platelet-rich plasma (PRP) obtained by centrifugation (10 min, 180 × g) of human venous blood (VB). PRP was mixed with the boundary layer formed between the supernatant and the erythrocyte layer. To achieve clots with different platelet counts, PRP was gradually substituted with platelet-free plasma (PFP), harvested from the supernatant of VB after centrifugation (10 min, 2570 × g). Clot types were examined for histological appearance, hydrodynamic resistance under physiological flows, and lysis rate measured by weight loss after a 2-h treatment with recombinant tissue plasminogen activator (rt-PA) (60 kU/ml). Lysis rates of the most suitable clot were measured after a 1-h treatment with rt-PA (60 kU/ml), and combined treatment with rt-PA and 2-MHz transcranial color-coded sonography (TCCS) (0.179 W/cm(2)) or 2-MHz transcranial Doppler (TCD) (0.457 W/cm(2)). With increased platelet count, the hydrodynamic resistance of the artificial clots increased, their histological appearance became more physiological, and lysis rates decreased. The most suitable clots consisted of 1.5-ml PRP, 2.0-ml PFP, and 0.5-ml boundary layer. Their lysis rates were 36.7 ± 7.8% (rt-PA), 40.8 ± 8.6% (rt-PA+TCCS), and 40.4 ± 8.3% (rt-PA+TCD). These systemic investigations were conducted for the first time. This protocol should be used for standardized sonothrombolysis investigations. Copyright © 2014 Elsevier B.V. All rights reserved.

  20. Application and analysis of geodetic protocols for monitoring subsidence phenomena along on-shore hydrocarbon reservoirs

    NASA Astrophysics Data System (ADS)

    Montuori, Antonio; Anderlini, Letizia; Palano, Mimmo; Albano, Matteo; Pezzo, Giuseppe; Antoncecchi, Ilaria; Chiarabba, Claudio; Serpelloni, Enrico; Stramondo, Salvatore

    2018-07-01

    In this study, we tested the "land-subsidence monitoring guidelines" proposed by the Italian Ministry of Economic Development (MISE), to study ground deformations along on-shore hydrocarbon reservoirs. We propose protocols that include the joint use of Global Positioning System (GPS) and multi-temporal Differential Interferometric Synthetic Aperture Radar (DInSAR) techniques, for a twofold purpose: a) monitoring land subsidence phenomena along selected areas after defining the background of ground deformations; b) analyzing possible relationships between hydrocarbon exploitation and anomalous deformation patterns. Experimental results, gathered along the Ravenna coastline (northern Italy) and in the southeastern Sicily (southern Italy), show wide areas of subsidence mainly related to natural and anthropogenic processes. Moreover, ground deformations retrieved through multi-temporal DInSAR time series exhibit low sensitivity as well as poor spatial and temporal correlation with hydrocarbon exploitation activities. Results allow evaluating the advantages and limitations of proposed protocols, to improve the techniques and security standards established by MISE guidelines for monitoring on-shore hydrocarbon reservoirs.

  1. Data Sharing to Improve Close Approach Monitoring and Safety of Flight

    NASA Astrophysics Data System (ADS)

    Chan, Joseph; DalBello, Richard; Hope, Dean; Wauthier, Pascal; Douglas, Tim; Inghram, Travis

    2009-03-01

    Individual satellite operators have done a good job of developing the internal protocols and procedures to ensure the safe operation of their fleets. However, data sharing among operators for close approach monitoring is conducted in an ad-hoc manner during relocations, and there is currently no standardized agreement among operators on the content, format, and distribution protocol for data sharing. Crowding in geostationary orbit, participation by new commercial actors, government interest in satellite constellations, and highly maneuverable spacecraft all suggest that satellite operators will need to begin a dialogue on standard communication protocols and procedure to improve situation awareness. We will give an overview of the current best practices among different operators for close approach monitoring and discuss the concept of an active data center to improve data sharing, conjunction monitoring, and avoidance among satellite operators. We will also report on the progress and lessons learned from a Data Center prototype conducted by several operators over a one year period.

  2. TH-E-209-03: Development of An In-House CT Dose Monitoring and Management System Based On Open-Source Software Resources -- Pearls and Pitfalls

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang, D.

    Radiation dose monitoring solutions have opened up new opportunities for medical physicists to be more involved in modern clinical radiology practices. In particular, with the help of comprehensive radiation dose data, data-driven protocol management and informed case follow up are now feasible. Significant challenges remain however and the problems faced by medical physicists are highly heterogeneous. Imaging systems from multiple vendors and a wide range of vintages co-exist in the same department and employ data communication protocols that are not fully standardized or implemented making harmonization complex. Many different solutions for radiation dose monitoring have been implemented by imaging facilitiesmore » over the past few years. Such systems are based on commercial software, home-grown IT solutions, manual PACS data dumping, etc., and diverse pathways can be used to bring the data to impact clinical practice. The speakers will share their experiences with creating or tailoring radiation dose monitoring/management systems and procedures over the past few years, which vary significantly in design and scope. Topics to cover: (1) fluoroscopic dose monitoring and high radiation event handling from a large academic hospital; (2) dose monitoring and protocol optimization in pediatric radiology; and (3) development of a home-grown IT solution and dose data analysis framework. Learning Objectives: Describe the scope and range of radiation dose monitoring and protocol management in a modern radiology practice Review examples of data available from a variety of systems and how it managed and conveyed. Reflect on the role of the physicist in radiation dose awareness.« less

  3. The importance of within-year repeated counts and the influence of scale on long-term monitoring of sage-grouse

    USGS Publications Warehouse

    Fedy, B.C.; Aldridge, Cameron L.

    2011-01-01

    Long-term population monitoring is the cornerstone of animal conservation and management. The accuracy and precision of models developed using monitoring data can be influenced by the protocols guiding data collection. The greater sage-grouse (Centrocercus urophasianus) is a species of concern that has been monitored over decades, primarily, by counting the number of males that attend lek (breeding) sites. These lek count data have been used to assess long-term population trends and for multiple mechanistic studies. However, some studies have questioned the efficacy of lek counts to accurately identify population trends. In response, monitoring protocols were changed to have a goal of counting lek sites multiple times within a season. We assessed the influence of this change in monitoring protocols on model accuracy and precision applying generalized additive models to describe trends over time. We found that at large spatial scales including >50 leks, the absence of repeated counts within a year did not significantly alter population trend estimates or interpretation. Increasing sample size decreased the model confidence intervals. We developed a population trend model for Wyoming greater sage-grouse from 1965 to 2008, identifying significant changes in the population indices and capturing the cyclic nature of this species. Most sage-grouse declines in Wyoming occurred between 1965 and the 1990s and lek count numbers generally increased from the mid-1990s to 2008. Our results validate the combination of monitoring data collected under different protocols in past and future studies-provided those studies are addressing large-scale questions. We suggest that a larger sample of individual leks is preferable to multiple counts of a smaller sample of leks. ?? 2011 The Wildlife Society.

  4. Protocol to monitor trade agreement food-related aspects: the Fiji case study.

    PubMed

    Ravuvu, Amerita; Friel, Sharon; Thow, Anne Marie; Snowdon, Wendy; Wate, Jillian

    2017-04-26

    Despite the growing rates of obesity and diet-related non-communicable diseases, globally, public health attention has only relatively recently turned to the links between trade agreements and the nutritional risks associated with it. Specific trade agreements appear to have played an influential role in the volume and types of foods entering different countries, yet there is currently no systematic and objective monitoring of trade agreements for their impacts on food environments. Recently, INFORMAS was set up to monitor and benchmark food environments, government policies and private sector actions within countries and globally. One of its projects/modules focuses on trade policy and in particular the food-related aspects of trade agreements. This paper describes the INFORMAS trade protocol, an approach to collecting food-related information about four domains of trade: trade in goods; trade in services and foreign direct investment; domestic supports, and policy space. Specifically, the protocol is tested in Fiji. The development and testing of this protocol in Fiji represents the first effort to set out a framework and process for objectively monitoring trade agreements and their impacts on national food supply and the wider food environment. It has shown that entry into WTO trade agreements contributed to the nutrition transition in Fiji through the increased availability of imported foods with varying nutritional quality. We observed an increase in imports of both healthy and less healthy foods. The application of the monitoring protocol also highlights challenges for data collection associated with each trade domain that should be considered for future data collection and analysis in other low and middle income countries. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  5. Validation of the Pangao PG-800A11 wrist device assessed according to the European Society of Hypertension and the British Hypertension Society protocols.

    PubMed

    Xie, Peigen; Wang, Yanling; Xu, Xiaoying; Huang, Fei; Pan, Jingru

    2015-04-01

    The objective of this study was to determine the accuracy of the Pangao PG-800A11 wrist blood pressure monitor according to the European Society of Hypertension International Protocol (ESH-IP) revision 2010 and the protocol of the British Hypertension Society (BHS). The device evaluations were performed in 85 participants, 33 of whom were included according to the ESH-IP revision 2010 and 52 of whom were included on the basis of the requirements of the BHS protocol. The validation procedure and data analysis followed the protocols precisely. The device achieved an A/A grading for the BHS protocol and passed all phases of the ESH-IP revision 2010 protocol. The mean difference ±SD for the ESH and BHS protocols, respectively, was -0.6±4.5 and -0.8±6.2 mmHg for systolic pressure and 1.2±4.6 and -0.5±5.1 mmHg for diastolic pressure. The device maintained its A/A grading throughout the low, medium, and high-pressure ranges. The Pangao PG-800A11 wrist blood pressure monitor passed all requirements of the ESH-IP revision 2010 and achieved A/A grade of the BHS protocol in an adult population.

  6. Fast Virtual Fractional Flow Reserve Based Upon Steady-State Computational Fluid Dynamics Analysis: Results From the VIRTU-Fast Study.

    PubMed

    Morris, Paul D; Silva Soto, Daniel Alejandro; Feher, Jeroen F A; Rafiroiu, Dan; Lungu, Angela; Varma, Susheel; Lawford, Patricia V; Hose, D Rodney; Gunn, Julian P

    2017-08-01

    Fractional flow reserve (FFR)-guided percutaneous intervention is superior to standard assessment but remains underused. The authors have developed a novel "pseudotransient" analysis protocol for computing virtual fractional flow reserve (vFFR) based upon angiographic images and steady-state computational fluid dynamics. This protocol generates vFFR results in 189 s (cf >24 h for transient analysis) using a desktop PC, with <1% error relative to that of full-transient computational fluid dynamics analysis. Sensitivity analysis demonstrated that physiological lesion significance was influenced less by coronary or lesion anatomy (33%) and more by microvascular physiology (59%). If coronary microvascular resistance can be estimated, vFFR can be accurately computed in less time than it takes to make invasive measurements.

  7. Improving the accuracy of blood pressure measurement: the influence of the European Society of Hypertension International Protocol (ESH-IP) for the validation of blood pressure measuring devices and future perspectives.

    PubMed

    Stergiou, George S; Asmar, Roland; Myers, Martin; Palatini, Paolo; Parati, Gianfranco; Shennan, Andrew; Wang, Jiguang; O'Brien, Eoin

    2018-03-01

    The European Society of Hypertension (ESH) International Protocol (ESH-IP) for the validation of blood pressure (BP) measuring devices was published in 2002, with the main objective of simplifying the validation procedures, so that more BP monitors would be subjected to independent validation. This article provides an overview of the international impact of the ESH-IP and of the lessons learned from its use, to be able to justify further developments in validation protocols. A review of published (PubMed) validation studies from 2002 to 2017 was performed. One hundred and seventy-seven validation studies using the ESH-IP, 59 using the British Hypertension Society protocol, 46 using the Association for the Advancement of Medical Instrumentation (AAMI) standard and 23 using the International Organization for Standardization (ISO) standard were identified. Lists of validated office-clinic, home and ambulatory BP monitors are provided. Of the ESH-IP studies, 93% tested oscillometric devices, 80% upper arm, 71% home, 25% office and 7% ambulatory monitors (some had more than one function). The original goal of the ESH-IP has been fulfilled in that in the last decade the number of published validation studies has more than doubled. It is now recognized that the provision of accurate devices would be best served by having a universal protocol. An international initiative has been put in place by AAMI, ESH and ISO experts aiming to reach consensus for a universal validation protocol to be accepted worldwide, which will allow a more thorough evaluation of the accuracy and performance of future BP monitors.

  8. Report from the NOAA workshops to standardize protocols for monitoring toxic Pfiesteria species and associated environmental conditions.

    PubMed

    Luttenberg, D; Turgeon, D; Higgins, J

    2001-10-01

    Long-term monitoring of water quality, fish health, and plankton communities in susceptible bodies of water is crucial to identify the environmental factors that contribute to outbreaks of toxic Pfiesteria complex (TPC) species. In the aftermath of the 1997 toxic Pfiesteria outbreaks in North Carolina and Maryland, federal and several state agencies agreed that there was a need to standardize monitoring protocols. The National Oceanic & Atmospheric Administration convened two workshops that brought together state, federal, and academic resource managers and scientific experts to a) seek consensus on responding to and monitoring potential toxic Pfiesteria outbreaks; b) recommend standard parameters and protocols to characterize water quality, fish health, and plankton at historical event sites and potentially susceptible sites; and c) discuss options for integrating monitoring data sets from different states into regional and national assessments. Workshop recommendations included the development of a three-tiered TPC monitoring strategy: Tier 1, rapid event response; Tier 2, comprehensive assessment; and Tier 3, routine monitoring. These tiers correspond to varying levels of water quality, fish health, and plankton monitoring frequency and intensity. Under the strategy, sites are prioritized, depending upon their history and susceptibility to TPC events, and assigned an appropriate level of monitoring activity. Participants also agreed upon a suite of water quality parameters that should be monitored. These recommendations provide guidance to state and federal agencies conducting rapid-response and assessment activities at sites of suspected toxic Pfiesteria outbreaks, as well as to states that are developing such monitoring programs for the first time.

  9. Functionality of empirical model-based predictive analytics for the early detection of hemodynamic instabilty.

    PubMed

    Summers, Richard L; Pipke, Matt; Wegerich, Stephan; Conkright, Gary; Isom, Kristen C

    2014-01-01

    Background. Monitoring cardiovascular hemodynamics in the modern clinical setting is a major challenge. Increasing amounts of physiologic data must be analyzed and interpreted in the context of the individual patient’s pathology and inherent biologic variability. Certain data-driven analytical methods are currently being explored for smart monitoring of data streams from patients as a first tier automated detection system for clinical deterioration. As a prelude to human clinical trials, an empirical multivariate machine learning method called Similarity-Based Modeling (“SBM”), was tested in an In Silico experiment using data generated with the aid of a detailed computer simulator of human physiology (Quantitative Circulatory Physiology or “QCP”) which contains complex control systems with realistic integrated feedback loops. Methods. SBM is a kernel-based, multivariate machine learning method that that uses monitored clinical information to generate an empirical model of a patient’s physiologic state. This platform allows for the use of predictive analytic techniques to identify early changes in a patient’s condition that are indicative of a state of deterioration or instability. The integrity of the technique was tested through an In Silico experiment using QCP in which the output of computer simulations of a slowly evolving cardiac tamponade resulted in progressive state of cardiovascular decompensation. Simulator outputs for the variables under consideration were generated at a 2-min data rate (0.083Hz) with the tamponade introduced at a point 420 minutes into the simulation sequence. The functionality of the SBM predictive analytics methodology to identify clinical deterioration was compared to the thresholds used by conventional monitoring methods. Results. The SBM modeling method was found to closely track the normal physiologic variation as simulated by QCP. With the slow development of the tamponade, the SBM model are seen to disagree while the simulated biosignals in the early stages of physiologic deterioration and while the variables are still within normal ranges. Thus, the SBM system was found to identify pathophysiologic conditions in a timeframe that would not have been detected in a usual clinical monitoring scenario. Conclusion. In this study the functionality of a multivariate machine learning predictive methodology that that incorporates commonly monitored clinical information was tested using a computer model of human physiology. SBM and predictive analytics were able to differentiate a state of decompensation while the monitored variables were still within normal clinical ranges. This finding suggests that the SBM could provide for early identification of a clinical deterioration using predictive analytic techniques. predictive analytics, hemodynamic, monitoring.

  10. RFID Technology for Continuous Monitoring of Physiological Signals in Small Animals.

    PubMed

    Volk, Tobias; Gorbey, Stefan; Bhattacharyya, Mayukh; Gruenwald, Waldemar; Lemmer, Björn; Reindl, Leonhard M; Stieglitz, Thomas; Jansen, Dirk

    2015-02-01

    Telemetry systems enable researchers to continuously monitor physiological signals in unrestrained, freely moving small rodents. Drawbacks of common systems are limited operation time, the need to house the animals separately, and the necessity of a stable communication link. Furthermore, the costs of the typically proprietary telemetry systems reduce the acceptance. The aim of this paper is to introduce a low-cost telemetry system based on common radio frequency identification technology optimized for battery-independent operational time, good reusability, and flexibility. The presented implant is equipped with sensors to measure electrocardiogram, arterial blood pressure, and body temperature. The biological signals are transmitted as digital data streams. The device is able of monitoring several freely moving animals housed in groups with a single reader station. The modular concept of the system significantly reduces the costs to monitor multiple physiological functions and refining procedures in preclinical research.

  11. A multiparameter wearable physiologic monitoring system for space and terrestrial applications

    NASA Technical Reports Server (NTRS)

    Mundt, Carsten W.; Montgomery, Kevin N.; Udoh, Usen E.; Barker, Valerie N.; Thonier, Guillaume C.; Tellier, Arnaud M.; Ricks, Robert D.; Darling, Robert B.; Cagle, Yvonne D.; Cabrol, Nathalie A.; hide

    2005-01-01

    A novel, unobtrusive and wearable, multiparameter ambulatory physiologic monitoring system for space and terrestrial applications, termed LifeGuard, is presented. The core element is a wearable monitor, the crew physiologic observation device (CPOD), that provides the capability to continuously record two standard electrocardiogram leads, respiration rate via impedance plethysmography, heart rate, hemoglobin oxygen saturation, ambient or body temperature, three axes of acceleration, and blood pressure. These parameters can be digitally recorded with high fidelity over a 9-h period with precise time stamps and user-defined event markers. Data can be continuously streamed to a base station using a built-in Bluetooth RF link or stored in 32 MB of on-board flash memory and downloaded to a personal computer using a serial port. The device is powered by two AAA batteries. The design, laboratory, and field testing of the wearable monitors are described.

  12. Non-contact physiological signal detection using continuous wave Doppler radar.

    PubMed

    Qiao, Dengyu; He, Tan; Hu, Boping; Li, Ye

    2014-01-01

    The aim of this work is to show non-contact physiological signal monitoring system based on continuous-wave (CW) Doppler radar, which is becoming highly attractive in the field of health care monitoring of elderly people. Two radar signal processing methods were introduced in this paper: one to extract respiration and heart rates of a single person and the other to separate mixed respiration signals. To verify the validity of the methods, physiological signal is obtained from stationary human subjects using a CW Doppler radar unit. The sensor operating at 24 GHz is located 0.5 meter away from the subject. The simulation results show that the respiration and heart rates are clearly extracted, and the mixed respiration signals are successfully separated. Finally, reference respiration and heart rate signals are measured by an ECG monitor and compared with the results tracked by the CW Doppler radar monitoring system.

  13. Real-Time Management of Multimodal Streaming Data for Monitoring of Epileptic Patients.

    PubMed

    Triantafyllopoulos, Dimitrios; Korvesis, Panagiotis; Mporas, Iosif; Megalooikonomou, Vasileios

    2016-03-01

    New generation of healthcare is represented by wearable health monitoring systems, which provide real-time monitoring of patient's physiological parameters. It is expected that continuous ambulatory monitoring of vital signals will improve treatment of patients and enable proactive personal health management. In this paper, we present the implementation of a multimodal real-time system for epilepsy management. The proposed methodology is based on a data streaming architecture and efficient management of a big flow of physiological parameters. The performance of this architecture is examined for varying spatial resolution of the recorded data.

  14. Heart rate variability and implication for sport concussion.

    PubMed

    Bishop, Scott A; Dech, Ryan T; Guzik, Przemyslaw; Neary, J Patrick

    2017-11-16

    Finding sensitive and specific markers for sports-related concussion is both challenging and clinically important. Such biomarkers might be helpful in the management of patients with concussion (i.e. diagnosis, monitoring and risk prediction). Among many parameters, blood flow-pressure metrics and heart rate variability (HRV) have been used to gauge concussion outcomes. Reports on the relation between HRV and both acute and prolonged concussion recovery are conflicting. While some authors report on differences in the low-frequency (LF) component of HRV during postural manipulations and postexercise conditions, others observe no significant differences in various HRV measures. Despite the early success of using the HRV LF for concussion recovery, the interpretation of the LF is debated. Recent research suggests the LF power is a net effect of several intrinsic modulatory factors from both sympathetic and parasympathetic branches of the autonomic nervous system, vagally mediated baroreflex and even some respiratory influences at lower respiratory rate. There are only a few well-controlled concussion studies that specifically examine the contribution of the autonomic nervous system branches with HRV for concussion management. This study reviews the most recent HRV- concussion literature and the underlying HRV physiology. It also highlights cerebral blood flow studies related to concussion and the importance of multimodal assessment of various biological signals. It is hoped that a better understanding of the physiology behind HRV might generate cost-effective, repeatable and reliable protocols, all of which will improve the interpretation of HRV throughout concussion recovery. © 2017 Scandinavian Society of Clinical Physiology and Nuclear Medicine. Published by John Wiley & Sons Ltd.

  15. Water quality monitoring protocol for wadeable streams and rivers in the Northern Great Plains Network

    USGS Publications Warehouse

    Wilson, Marcia H.; Rowe, Barbara L.; Gitzen, Robert A.; Wilson, Stephen K.; Paintner-Green, Kara J.

    2014-01-01

    As recommended by Oakley et al. (2003), this protocol provides a narrative and the rationale for selection of streams and rivers within the NGPN that will be measured for water quality, including dissolved oxygen, pH, specific conductivity, and temperature. Standard operating procedures (SOPs) that detail the steps to collect, manage, and disseminate the NGPN water quality data are in an accompanying document. The sampling design documented in this protocol may be updated as monitoring information is collected and interpreted, and as refinement of methodologies develop through time. In addition, evaluation of data and refinement of the program may necessitate potential changes of program objectives. Changes to the NGPN water quality protocols and SOPs will be carefully documented in a revision history log.

  16. Sensing interstitial glucose to nudge active lifestyles (SIGNAL): feasibility of combining novel self-monitoring technologies for persuasive behaviour change

    PubMed Central

    Kingsnorth, Andrew P; Orme, Mark W; Sherar, Lauren B; Esliger, Dale W

    2017-01-01

    Introduction Increasing physical activity (PA) reduces the risk of developing diabetes, highlighting the role of preventive medicine approaches. Changing lifestyle behaviours is difficult and is often predicated on the assumption that individuals are willing to change their lifestyles today to reduce the risk of developing disease years or even decades later. The self-monitoring technologies tested in this study will present PA feedback in real time, parallel with acute physiological data. Presenting the immediate health benefits of being more physically active may help enact change by observing the immediate consequences of that behaviour. The present study aims to assess user engagement with the self-monitoring technologies in individuals at moderate-to-high risk of developing type 2 diabetes. Methods and analysis 45 individuals with a moderate-to-high risk, aged ≥40 years old and using a compatible smartphone, will be invited to take part in a 7-week protocol. Following 1 week of baseline measurements, participants will be randomised into one of three groups: group 1— glucose feedback followed by biobehavioural feedback (glucose plus PA); group 2—PA feedback followed by biobehavioural feedback; group 3—biobehavioural feedback. A PA monitor and a flash glucose monitor will be deployed during the intervention. Participants will wear both devices throughout the intervention but blinded to feedback depending on group allocation. The primary outcome is the level of participant engagement and will be assessed by device use and smartphone usage. Feasibility will be assessed by the practicality of the technology and screening for diabetes risk. Semistructured interviews will be conducted to explore participant experiences using the technologies. Trial registration number ISRCTN17545949. Registered on 15/05/2017. PMID:28993396

  17. Metabolic products as biomarkers

    USGS Publications Warehouse

    Melancon, M.J.; Alscher, R.; Benson, W.; Kruzynski, G.; Lee, R.F.; Sikka, H.C.; Spies, R.B.; Huggett, Robert J.; Kimerle, Richard A.; Mehrle, Paul M.=; Bergman, Harold L.

    1992-01-01

    Ideally, endogenous biomarkers would indicate both exposure and environmental effects of toxic chemicals; however, such comprehensive biochemical and physiological indices are currently being developed and, at the present time, are unavailable for use in environmental monitoring programs. Continued work is required to validate the use of biochemical and physiological stress indices as useful components of monitoring programs. Of the compounds discussed only phytochelatins and porphyrins are currently in biomarkers in a useful state; however, glutathione,metallothioneins, stress ethylene, and polyamines are promising as biomarkers in environmental monitoring.

  18. Assessing very high resolution UAV imagery for monitoring forest health during a simulated disease outbreak

    NASA Astrophysics Data System (ADS)

    Dash, Jonathan P.; Watt, Michael S.; Pearse, Grant D.; Heaphy, Marie; Dungey, Heidi S.

    2017-09-01

    Research into remote sensing tools for monitoring physiological stress caused by biotic and abiotic factors is critical for maintaining healthy and highly-productive plantation forests. Significant research has focussed on assessing forest health using remotely sensed data from satellites and manned aircraft. Unmanned aerial vehicles (UAVs) may provide new tools for improved forest health monitoring by providing data with very high temporal and spatial resolutions. These platforms also pose unique challenges and methods for health assessments must be validated before use. In this research, we simulated a disease outbreak in mature Pinus radiata D. Don trees using targeted application of herbicide. The objective was to acquire a time-series simulated disease expression dataset to develop methods for monitoring physiological stress from a UAV platform. Time-series multi-spectral imagery was acquired using a UAV flown over a trial at regular intervals. Traditional field-based health assessments of crown health (density) and needle health (discolouration) were carried out simultaneously by experienced forest health experts. Our results showed that multi-spectral imagery collected from a UAV is useful for identifying physiological stress in mature plantation trees even during the early stages of tree stress. We found that physiological stress could be detected earliest in data from the red edge and near infra-red bands. In contrast to previous findings, red edge data did not offer earlier detection of physiological stress than the near infra-red data. A non-parametric approach was used to model physiological stress based on spectral indices and was found to provide good classification accuracy (weighted kappa = 0.694). This model can be used to map physiological stress based on high-resolution multi-spectral data.

  19. Sensitive Quantitative Assessment of Balance Disorders

    NASA Technical Reports Server (NTRS)

    Paloski, Willilam H.

    2007-01-01

    Computerized dynamic posturography (CDP) has become a standard technique for objectively quantifying balance control performance, diagnosing the nature of functional impairments underlying balance disorders, and monitoring clinical treatment outcomes. We have long used CDP protocols to assess recovery of sensory-motor function in astronauts following space flight. The most reliable indicators of post-flight crew performance are the sensory organization tests (SOTs), particularly SOTs 5 and 6, which are sensitive to changes in availability and/or utilization of vestibular cues. We have noted, however, that some astronauts exhibiting obvious signs of balance impairment after flight are able to score within clinical norms on these tests, perhaps as a result of adopting competitive strategies or by their natural skills at substituting alternate sensory information sources. This insensitivity of the CDP protocol could underestimate of the degree of impairment and, perhaps, lead to premature release of those crewmembers to normal duties. To improve the sensitivity of the CDP protocol we have introduced static and dynamic head tilt SOT trials into our protocol. The pattern of postflight recovery quantified by the enhanced CDP protocol appears to more aptly track the re-integration of sensory-motor function, with recovery time increasing as the complexity of sensory-motor/biomechanical task increases. The new CDP protocol therefore seems more suitable for monitoring post-flight sensory-motor recovery and for indicating to crewmembers and flight surgeons fitness for return to duty and/or activities of daily living. There may be classes of patients (e.g., athletes, pilots) having motivation and/or performance characteristics similar to astronauts whose sensory-motor treatment outcomes would also be more accurately monitored using the enhanced CDP protocol. Furthermore, the enhanced protocol may be useful in early detection of age-related balance disorders.

  20. Monitoring intervention fidelity of a lifestyle behavioral intervention delivered through telehealth

    PubMed Central

    Sineath, Ashley; Lambert, Lauren; Verga, Catherine; Wagstaff, Miranda

    2017-01-01

    Background Technology-based lifestyle behavioral interventions (i.e., telehealth, mHealth, eHealth, and/or digital health) are becoming an alternative standard of care and possess several advantages over traditional clinical settings such as convenience, cost, and the ability to tailor plans and feedback to a participant’s individual needs. These technology-based interventions also present unique challenges to intervention fidelity due to extra elements involved in executing the intervention. Intervention fidelity monitoring is essential to ensure internal and external validity, yet the development and utilization of fidelity protocols is under-reported in the literature. The purpose of this paper is to describe the intervention fidelity protocol for the 24-START study, a behavior change intervention delivered through telephone and internet. This paper also discusses the results of a pilot audit conducted to determine the feasibility of monitoring adherence to the fidelity protocol. Methods The 24-START fidelity protocol was developed in accordance with the five fidelity areas outlined by the NIH Behavior Change Consortium (NIH BCC) including: design of study, provider training, delivery of treatment, receipt of treatment, and enactment of treatment. The fidelity strategies provided by the NIH BCC in each area were tailored to fit the specific design of the 24-START study. Twenty-six total fidelity strategies were developed in accordance with the five areas and a corresponding fidelity monitoring plan was created. Because these strategies are only beneficial if implemented, the fidelity monitoring plan was developed to ensure the fidelity strategies are consistently implemented over the course of the intervention. Results A pilot audit of nine participant files was conducted to test the feasibility of the fidelity protocol developed. Out of the nine participant files reviewed, 89% of scheduled phone calls between a telehealth coach and participant were successfully completed. Of the completed calls, telehealth coaches delivered the intervention as intended 85.3% of the time, and 74% of planned secondary contacts made through the internet were delivered successfully. Additionally, between treatment group dosing was found to be equal. Several weak areas in the fidelity protocol were identified for improvement. The results were satisfactory and the audit was deemed feasible for ongoing use. Conclusions The NIH BCC provides a valuable framework for telehealth interventions to develop fidelity protocols ultimately contributing to improved internal and external validity, better translation of results, increased transparency, and increased opportunities for replication within the field. The 24-START pilot audit found the fidelity protocol efficacious and feasible while also identifying areas of weakness in need of revision. The refined protocol will continue to be utilized throughout the data collection phase. Future telehealth interventions should develop and disclose fidelity protocols to improve the overall quality and standard of telehealth interventions. PMID:28894745

  1. Monitoring intervention fidelity of a lifestyle behavioral intervention delivered through telehealth.

    PubMed

    Sineath, Ashley; Lambert, Lauren; Verga, Catherine; Wagstaff, Miranda; Wingo, Brooks C

    2017-01-01

    Technology-based lifestyle behavioral interventions (i.e., telehealth, mHealth, eHealth, and/or digital health) are becoming an alternative standard of care and possess several advantages over traditional clinical settings such as convenience, cost, and the ability to tailor plans and feedback to a participant's individual needs. These technology-based interventions also present unique challenges to intervention fidelity due to extra elements involved in executing the intervention. Intervention fidelity monitoring is essential to ensure internal and external validity, yet the development and utilization of fidelity protocols is under-reported in the literature. The purpose of this paper is to describe the intervention fidelity protocol for the 24-START study, a behavior change intervention delivered through telephone and internet. This paper also discusses the results of a pilot audit conducted to determine the feasibility of monitoring adherence to the fidelity protocol. The 24-START fidelity protocol was developed in accordance with the five fidelity areas outlined by the NIH Behavior Change Consortium (NIH BCC) including: design of study, provider training, delivery of treatment, receipt of treatment, and enactment of treatment. The fidelity strategies provided by the NIH BCC in each area were tailored to fit the specific design of the 24-START study. Twenty-six total fidelity strategies were developed in accordance with the five areas and a corresponding fidelity monitoring plan was created. Because these strategies are only beneficial if implemented, the fidelity monitoring plan was developed to ensure the fidelity strategies are consistently implemented over the course of the intervention. A pilot audit of nine participant files was conducted to test the feasibility of the fidelity protocol developed. Out of the nine participant files reviewed, 89% of scheduled phone calls between a telehealth coach and participant were successfully completed. Of the completed calls, telehealth coaches delivered the intervention as intended 85.3% of the time, and 74% of planned secondary contacts made through the internet were delivered successfully. Additionally, between treatment group dosing was found to be equal. Several weak areas in the fidelity protocol were identified for improvement. The results were satisfactory and the audit was deemed feasible for ongoing use. The NIH BCC provides a valuable framework for telehealth interventions to develop fidelity protocols ultimately contributing to improved internal and external validity, better translation of results, increased transparency, and increased opportunities for replication within the field. The 24-START pilot audit found the fidelity protocol efficacious and feasible while also identifying areas of weakness in need of revision. The refined protocol will continue to be utilized throughout the data collection phase. Future telehealth interventions should develop and disclose fidelity protocols to improve the overall quality and standard of telehealth interventions.

  2. AN AUTOMATED MONITORING SYSTEM FOR FISH PHYSIOLOGY AND TOXICOLOGY

    EPA Science Inventory

    This report describes a data acquisition and control (DAC) system that was constructed to manage selected physiological measurements and sample control for aquatic physiology and toxicology. Automated DAC was accomplished with a microcomputer running menu-driven software develope...

  3. SU-F-P-04: Implementation of Dose Monitoring Software: Successes and Pitfalls

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Och, J

    2016-06-15

    Purpose: to successfully install a dose monitoring software (DMS) application to assist in CT protocol and dose management. Methods: Upon selecting the DMS, we began our implementation of the application. A working group composed of Medical Physics, Radiology Administration, Information Technology, and CT technologists was formed. On-site training in the application was supplied by the vendor. The decision was made to apply the process for all the CT protocols on all platforms at all facilities. Protocols were painstakingly mapped to the correct masters, and the system went ‘live’. Results: We are routinely using DMS as a tool in our Clinicalmore » Performance CT QA program. It is useful in determining the effectiveness of revisions to existing protocols, and establishing performance baselines for new units. However, the implementation was not without difficulty. We identified several pitfalls and obstacles which frustrated progress. Including: Training deficiencies, Nomenclature problems, Communication, DICOM variability. Conclusion: Dose monitoring software can be a potent tool for QA. However, implementation of the program can be problematic and requires planning, organization and commitment.« less

  4. Social defeat protocol and relevant biomarkers, implications for stress response physiology, drug abuse, mood disorders and individual stress vulnerability: a systematic review of the last decade.

    PubMed

    Vasconcelos, Mailton; Stein, Dirson João; de Almeida, Rosa Maria M

    2015-01-01

    Social defeat (SD) in rats, which results from male intraspecific confrontations, is ethologically relevant and useful to understand stress effects on physiology and behavior. A systematic review of studies about biomarkers induced by the SD protocol and published from 2002 to 2013 was carried out in the electronic databases PubMed, Web of Knowledge and ScienceDirect. The search terms were: social defeat, rat, neurotrophins, neuroinflammatory markers, and transcriptional factors. Classical and recently discovered biomarkers were found to be relevant in stress-induced states. Findings were summarized in accordance to the length of exposure to stress: single, repeated, intermittent and continuous SD. This review found that the brain-derived neurotrophic factor (BDNF) is a distinct marker of stress adaptation. Along with glucocorticoids and catecholamines, BDNF seems to be important in understanding stress physiology. The SD model provides a relevant tool to study stress response features, development of addictive behaviors, clinic depression and anxiety, as well as individual differences in vulnerability and resilience to stress.

  5. Cardiorespiratory physiology in the safe passage study: protocol, methods and normative values in unexposed infants.

    PubMed

    Myers, Michael M; Elliott, Amy J; Odendaal, Hein J; Burd, Larry; Angal, Jyoti; Groenewald, Coen; Nugent, James David; Yang, Joel S; Isler, Joseph R; Dukes, Kim A; Robinson, Fay; Fifer, William P

    2017-08-01

    The Safe Passage Study, conducted by the Prenatal Alcohol in SIDS and Stillbirth Network, is investigating contributions of prenatal alcohol exposure to foetal and infant demise. This current report presents physiological data from full-term infants with no prenatal exposure to alcohol or maternal smoking. Data are from 666 infants from the Northern Plains (North and South Dakota) and South Africa. A standardised protocol assessed cardiorespiratory function during baseline and head-up tilts shortly after birth and at one month of age. Analyses revealed significant increases in heart rate and decreases in BP from the newborn to one-month time period as well as diminished heart rate responses to head-up tilt in one-month-old infants. The Safe Passage Study was successful in characterising physiology in a large number of infants at sites known to have elevated risks for SIDS. Results demonstrate that even with low prenatal adverse exposures, there are significant changes in cardiorespiratory function as infants enter the window of increased risk for SIDS. ©2017 Foundation Acta Paediatrica. Published by John Wiley & Sons Ltd.

  6. Development of environmental impact monitoring protocol for offshore carbon capture and storage (CCS): A biological perspective

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kim, Hyewon, E-mail: hyewon@ldeo.columbia.edu; Kim, Yong Hoon, E-mail: Yong.Kim@rpsgroup.com; Kang, Seong-Gil, E-mail: kangsg@kriso.re.kr

    Offshore geologic storage of carbon dioxide (CO{sub 2}), known as offshore carbon capture and sequestration (CCS), has been under active investigation as a safe, effective mitigation option for reducing CO{sub 2} levels from anthropogenic fossil fuel burning and climate change. Along with increasing trends in implementation plans and related logistics on offshore CCS, thorough risk assessment (i.e. environmental impact monitoring) needs to be conducted to evaluate potential risks, such as CO{sub 2} gas leakage at injection sites. Gas leaks from offshore CCS may affect the physiology of marine organisms and disrupt certain ecosystem functions, thereby posing an environmental risk. Here,more » we synthesize current knowledge on environmental impact monitoring of offshore CCS with an emphasis on biological aspects and provide suggestions for better practice. Based on our critical review of preexisting literatures, this paper: 1) discusses key variables sensitive to or indicative of gas leakage by summarizing physico-chemical and ecological variables measured from previous monitoring cruises on offshore CCS; 2) lists ecosystem and organism responses to a similar environmental condition to CO{sub 2} leakage and associated impacts, such as ocean acidification and hypercapnia, to predict how they serve as responsive indicators of short- and long-term gas exposure, and 3) discusses the designs of the artificial gas release experiments in fields and the best model simulation to produce realistic leakage scenarios in marine ecosystems. Based on our analysis, we suggest that proper incorporation of biological aspects will provide successful and robust long-term monitoring strategies with earlier detection of gas leakage, thus reducing the risks associated with offshore CCS. - Highlights: • This paper synthesizes the current knowledge on environmental impact monitoring of offshore Carbon Capture and Sequestration (CCS). • Impacts of CO{sub 2} leakage (ocean acidification, hypercapnia) on marine organisms and ecosystems are discussed. • Insights and recommendations on EIA monitoring for CCS operations are proposed specifically in marine ecosystem perspective.« less

  7. Remote physiological monitoring in an austere environment: a future for battlefield care provision?

    PubMed

    Smyth, Matthew J; Round, J A; Mellor, A J

    2018-05-14

    Wearable technologies are making considerable advances into the mainstream as they become smaller and more user friendly. The global market for such devices is forecasted to be worth over US$5 billion in 2018, with one in six people owning a device. Many professional sporting teams use self-monitoring to assess physiological parameters and work rate on the pitch, highlighting the potential utility for military command chains. As size of device reduces and sensitivity improves, coupled with remote connectivity technology, integration into the military environment could be relatively seamless. Remote monitoring of personnel on the ground, giving live updates on their physiological status, would allow commanders or medical officers the ability to manage their soldiers appropriately and improve combat effectiveness. This paper explores a proof of concept for the use of a self-monitoring system in the austere high altitude environment of the Nepalese Himalayas, akin to those experienced by modern militaries fighting in remote locations. It also reviews, in part, the historical development of remote monitoring technologies. The system allowed for physiological recordings, plotted against GPS position, to be remotely monitored in Italy. Examples of the data recorded are given and the performance of the system is discussed, including limitations, potential areas of development and how systems like this one could be integrated into the military environment. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  8. Validation of the Medisana MTP Plus upper arm blood pressure monitor, for self-measurement, according to the European Society of Hypertension International Protocol revision 2010.

    PubMed

    Erdem, Emre; Aydogdu, Türkan; Akpolat, Tekin

    2011-02-01

    Standard validation protocols are objective guides for healthcare providers, physicians, and patients. The purpose of this study was to test validation of the Medisana MTP Plus upper arm blood pressure (BP) measuring monitor for self-measurement according to the European Society of Hypertension International Protocol (ESH-IP2) in adults. The Medisana MTP Plus monitor is an automated and oscillometric upper arm device for home BP monitoring. Nine consecutive measurements were made according to the ESH-IP2. Overseen by an independent supervisor, measurements were recorded by two observers blinded from both each other's readings and from the device readings. The Medisana MTP Plus device fulfills the validation criteria of the ESH-IP2 for the general population. The mean (standard deviation) of the difference between the observers and the device measurements was 0.6 mmHg (5.1 mmHg) for systolic and 2.7 mmHg (3.4 mmHg) for diastolic pressures, respectively. As the Medisana MTP Plus device has achieved the required standards, it is recommended for home BP monitoring in an adult population.

  9. Validation of the SEJOY BP-1307 upper-arm blood pressure monitor for home blood pressure monitoring according to the European Society of Hypertension International Protocol revision 2010.

    PubMed

    Lei, Lei; Chen, Yi; Chen, Qi; Li, Yan; Wang, Ji-Guang

    2017-12-01

    The present study aimed to evaluate the accuracy of the automated oscillometric upper-arm blood pressure monitor SEJOY BP-1307 (also called JOYTECH DBP-1307) for home blood pressure monitoring according to the International Protocol of the European Society of Hypertension revision 2010. Systolic and diastolic blood pressures were sequentially measured in 33 adult Chinese individuals (13 women, 45.1 years of mean age) using a mercury sphygmomanometer (two observers) and the SEJOY BP-1307 device (one supervisor). Ninety-nine pairs of comparisons were obtained from 33 participants for judgments in two parts with three grading phases. The average±SD of the device-observer differences was 0.2±4.1 and -1.7±4.7 mmHg for systolic and diastolic blood pressure, respectively. The SEJOY BP-1307 device achieved the criteria in both part 1 and part 2 of the validation study. The SEJOY upper-arm blood pressure monitor BP-1307 has passed the requirements of the International Protocol revision 2010, and hence can be recommended for home use in adults.

  10. Reproductive performance of lactating dairy cows managed for first service using timed artificial insemination with or without detection of estrus using an activity-monitoring system.

    PubMed

    Fricke, P M; Giordano, J O; Valenza, A; Lopes, G; Amundson, M C; Carvalho, P D

    2014-05-01

    Lactating dairy cows (n=1,025) on a commercial dairy farm were randomly assigned at 10 ± 3 d in milk (DIM) to 1 of 3 treatments for submitting cows to first artificial insemination (AI) and were fitted with activity-monitoring tags (Heatime; SCR Engineers Ltd., Netanya, Israel) at 24 ± 3 DIM. Cows (n=339) in treatment 1 were inseminated based on increased activity from the end of the voluntary waiting period (50 DIM) until submission to an Ovsynch protocol; cows without increased activity from 21 to 65 DIM began an Ovsynch protocol at 65 ± 3 DIM, whereas cows without increased activity from 21 to 50 DIM but not from 51 to 79 DIM began an Ovsynch protocol at 79 ± 3 DIM. Cows (n=340) in treatment 2 were inseminated based on activity after the second PGF2α injection of a Presynch-Ovsynch protocol at 50 DIM, and cows without increased activity began an Ovsynch protocol at 65 ± 3 DIM. Cows (n=346) in treatment 3 were monitored for activity after the second PGF2α injection of a Presynch-Ovsynch protocol, but all cows received timed AI (TAI) at 75 ± 3 DIM after completing the Presynch-Ovsynch protocol. The activity-monitoring system detected increased activity in 56, 69, and 70% of cows in treatments 1, 2, and 3, respectively. Treatment-2 cows had the fewest average days to first AI (62.5), treatment-3 cows had the most average days to first AI (74.9), and treatment-1 cows had intermediate average days to first AI (67.4). Treatment-1 and -2 cows in which inseminations occurred as a combination between increased activity and TAI had fewer overall pregnancies per AI (P/AI) 35 d after AI (32% for both treatments) compared with treatment-3 cows, all of which received TAI after completing the Presynch-Ovsynch protocol (40%). Based on survival analysis, although the rate at which cows were inseminated differed among treatments, treatment did not affect the proportion of cows pregnant by 300 DIM. Thus, use of an activity-monitoring system to inseminate cows based on activity reduced days to first AI, whereas cows receiving 100% TAI after completing a Presynch-Ovsynch protocol had more P/AI. The trade-off between AI service rate and P/AI in the rate at which cows became pregnant was supported by an economic analysis in which the net present value ($/cow per year) differed by only $4 to $8 among treatments. We conclude that a variety of strategies using a combination of AI based on increased activity using an activity-monitoring system and synchronization of ovulation and TAI can be used to submit cows for first AI. Copyright © 2014 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  11. Quality assurance of research protocols conducted in the community: the National Institute on Drug Abuse Clinical Trials Network experience.

    PubMed

    Rosa, Carmen; Campbell, Aimee; Kleppinger, Cynthia; Sampson, Royce; Tyson, Clare; Mamay-Gentilin, Stephanie

    2009-04-01

    Quality assurance (QA) of clinical trials is essential to protect the welfare of trial participants and the integrity of the data collected. However, there is little detailed information available on specific procedures and outcomes of QA monitoring for clinical trials. This article describes the experience of the National Institute on Drug Abuse's (NIDA) National Drug Abuse Treatment Clinical Trials Network (CTN) in devising and implementing a three-tiered QA model for rigorous multi-site randomized clinical trials implemented in community-based substance abuse treatment programs. The CTN QA model combined local and national resources and was developed to address the unique needs of clinical trial sites with limited research experience. The authors reviewed internal records maintained by the sponsor, a coordinating site (Lead Nodes), and a local site detailing procedural development, training sessions, protocol violation monitoring, and site visit reporting. Between January 2001 and September 2005, the CTN implemented 21 protocols, of which 18 were randomized clinical trials, one was a quality improvement study and two were surveys. Approximately 160 community-based treatment programs participated in the 19 studies that were monitored, with a total of 6560 participants randomized across the sites. During this time 1937 QA site visits were reported across the three tiers of monitoring and the cost depended on the location of the sites and the salaries of the staff involved. One study reported 109 protocol violations (M = 15.6). Examples are presented to highlight training, protocol violation monitoring, site visit frequency and intensity and cost considerations. : QA data from the entire network were not easily available for review as much of the data were not electronically accessible. The authors reviewed and discussed a representative sample of internal data from the studies and participating sites. The lessons learned from the CTN's experience include the need for balancing thoroughness with efficiency, monitoring early, assessing research staff abilities in order to judge the need for proactive, focused attention, providing targeted training sessions, and developing flexible tools. The CTN model can work for sponsors overseeing studies at sites with limited research experience that require more frequent, in-depth monitoring. We recommend that sponsors not develop a rigid monitoring approach, but work with the study principal investigators to determine the intensity of monitoring needed depending on trial complexity, the risks of the intervention(s), and the experience of the staff with clinical research. After careful evaluation, sponsors should then determine the best approach to site monitoring and what resources will be needed.

  12. Quality assurance of research protocols conducted in the community: The National Institute on Drug Abuse Clinical Trials Network Experience

    PubMed Central

    Rosa, Carmen; Campbell, Aimee; Kleppinger, Cynthia; Sampson, Royce; Tyson, Clare; Mamay-Gentilin, Stephanie

    2009-01-01

    Background: Quality assurance (QA) of clinical trials is essential to protect the welfare of trial participants and the integrity of the data collected. However, there is little detailed information available on specific procedures and outcomes of QA monitoring for clinical trials. Purpose: This article describes the experience of the National Institute on Drug Abuse's (NIDA) National Drug Abuse Treatment Clinical Trials Network (CTN) in devising and implementing a three-tiered QA model for rigorous multi-site randomized clinical trials implemented in community-based substance abuse treatment programs. The CTN QA model combined local and national resources and was developed to address the unique needs of clinical trial sites with limited research experience. Methods: The authors reviewed internal records maintained by the sponsor, a coordinating site (Lead Nodes), and a local site detailing procedural development, training sessions, protocol violation monitoring, and site visit reporting. Results: Between January 2001 and September 2005, the CTN implemented 21 protocols, of which 18 were randomized clinical trials, one was a quality improvement study and two were surveys. Approximately 160 community-based treatment programs participated in the 19 studies that were monitored, with a total of 6560 participants randomized across the sites. During this time 1937 QA site visits were reported across the three tiers of monitoring and the cost depended on the location of the sites and the salaries of the staff involved. One study reported 109 protocol violations (M = 15.6). Examples are presented to highlight training, protocol violation monitoring, site visit frequency and intensity and cost considerations. Limitations: QA data from the entire network were not easily available for review as much of the data were not electronically accessible. The authors reviewed and discussed a representative sample of internal data from the studies and participating sites. Conclusions: The lessons learned from the CTN's experience include the need for balancing thoroughness with efficiency, monitoring early, assessing research staff abilities in order to judge the need for proactive, focused attention, providing targeted training sessions, and developing flexible tools. The CTN model can work for sponsors overseeing studies at sites with limited research experience that require more frequent, in-depth monitoring. We recommend that sponsors not develop a rigid monitoring approach, but work with the study principal investigators to determine the intensity of monitoring needed depending on trial complexity, the risks of the intervention(s), and the experience of the staff with clinical research. After careful evaluation, sponsors should then determine the best approach to site monitoring and what resources will be needed. PMID:19342468

  13. The acute effects of graded physiological strain on soccer kicking performance: a randomized, controlled cross-over study.

    PubMed

    Radman, Ivan; Wessner, Barbara; Bachl, Norbert; Ruzic, Lana; Hackl, Markus; Prpic, Tomislav; Markovic, Goran

    2016-02-01

    The aim of the present study was to examine the acute effects of graded physiological strain on soccer kicking performance. Twenty-eight semi-professional soccer players completed both experimental and control procedure. The experimental protocol incorporated repeated shooting trials combined with a progressive discontinuous maximal shuttle-run intervention. The initial running velocity was 8 km/h and increasing for 1 km/h every 3 min until exhaustion. The control protocol comprised only eight subsequent shooting trials. The soccer-specific kicking accuracy (KA; average distance from the ball-entry point to the goal center), kicking velocity (KV), and kicking quality (KQ; kicking accuracy divided by the time elapsed from hitting the ball to the point of entry) were evaluated via reproducible and valid test over five individually determined exercise intensity zones. Compared with baseline or exercise at intensities below the second lactate threshold (LT2), physiological exertion above the LT2 (blood lactate > 4 mmol/L) resulted in meaningful decrease in KA (11-13%; p < 0.05), KV (3-4%; p < 0.05), and overall KQ (13-15%; p < 0.01). The light and moderate-intensity exercise below the LT2 had no significant effect on soccer kicking performance. The results suggest that high-intensity physiological exertion above the player's LT2 impairs soccer kicking performance. In contrast, light to moderate physiological stress appears to be neither harmful nor beneficial for kicking performance.

  14. Guidance Protocol: Application of Nucleic Acid-Based Tools for Monitoring Monitored Natural Attenuation (MNA), Biostimulation, and Bioaugmentation at Chlorinated Solvent Sites

    DTIC Science & Technology

    2011-02-01

    Reductive dechlorination is a promising process for biodegradation of chlorinated solvents. The successful field evaluation and implementation of the...population. These specialized bacteria use the chlorinated ethenes as electron acceptors and gain energy for growth from the reductive...This guidance protocol addresses the use of MBTs to quantitatively assess the Dhc population at chlorinated ethene sites and aims at providing

  15. Wildlife feeding in parks: methods for monitoring the effectiveness of educational interventions and wildlife food attraction behaviors

    USGS Publications Warehouse

    Marion, Jeffrey L.; Dvorak, Robert G.; Manning, Robert E.

    2008-01-01

    Opportunities to view and interact with wildlife are often an important part of high quality recreational experiences. Such interactions frequently include wildlife feeding, resulting in food-conditioned behaviors that may cause harm to both wildlife and visitors. This study developed and applied efficient protocols for simultaneously evaluating wildlife feeding-related behaviors of visitors and related foraging behaviors of chipmunks along a trail in Zion National Park. Unobtrusive observation protocols permitted an evaluation of educational messages delivered, and documentation of wildlife success in obtaining human food and the strength of their food attraction behavior. Significant improvements were documented for some targeted visitor behaviors and human food available to chipmunks, with minor differences between treatments. Replication of these protocols as part of a long-term monitoring program can help protected area managers evaluate and improve the efficacy of their interventions and monitor the strength of food attraction behavior in wildlife.

  16. Postdoctoral Fellowship for Dr. Lindholm, Underwater Physiology and Medicine

    DTIC Science & Technology

    2008-05-01

    St Croix 2000) and/or an increased reliance on fast twitch muscle fibers that are dependent on glycogen and produce La. The changes in muscle and...resistance protocol ( isometric ) increases respiratory muscle strength but not endurance, while, a protocol designed to increase respiratory muscle endurance... muscles (RMT). RMT minimized respiratory muscle fatigue and normalized the ventilatory response to increasing C02 (C02 sensitivity) and blood C02 in C02

  17. Monitoring protocols: options, approaches, implementation, benefits

    USDA-ARS?s Scientific Manuscript database

    Monitoring and adaptive management are fundamental concepts to rangeland management across land management agencies and embodied as best management practices for private landowners. Historically, rangeland monitoring was limited to determining impacts or maximizing the potential of specific land use...

  18. Recreation Embedded State Tuning for Optimal Readiness and Effectiveness (RESTORE)

    NASA Technical Reports Server (NTRS)

    Pope, Alan T.; Prinzel, Lawrence J., III

    2005-01-01

    Physiological self-regulation training is a behavioral medicine intervention that has demonstrated capability to improve psychophysiological coping responses to stressful experiences and to foster optimal behavioral and cognitive performance. Once developed, these psychophysiological skills require regular practice for maintenance. A concomitant benefit of these physiologically monitored practice sessions is the opportunity to track crew psychophysiological responses to the challenges of the practice task in order to detect shifts in adaptability that may foretell performance degradation. Long-duration missions will include crew recreation periods that will afford physiological self-regulation training opportunities. However, to promote adherence to the regimen, the practice experience that occupies their recreation time must be perceived by the crew as engaging and entertaining throughout repeated reinforcement sessions on long-duration missions. NASA biocybernetic technologies and publications have developed a closed-loop concept that involves adjusting or modulating (cybernetic, for governing) a person's task environment based upon a comparison of that person's physiological responses (bio-) with a training or performance criterion. This approach affords the opportunity to deliver physiological self-regulation training in an entertaining and motivating fashion and can also be employed to create a conditioned association between effective performance state and task execution behaviors, while enabling tracking of individuals psychophysiological status over time in the context of an interactive task challenge. This paper describes the aerospace spin-off technologies in this training application area as well as the current spin-back application of the technologies to long-duration missions - the Recreation Embedded State Tuning for Optimal Readiness and Effectiveness (RESTORE) concept. The RESTORE technology is designed to provide a physiological self-regulation training countermeasure for maintaining and reinforcing cognitive readiness, resilience under psychological stress, and effective mood states in long-duration crews. The technology consists of a system for delivering physiological self-regulation training and for tracking crew central and autonomic nervous system function; the system interface is designed to be experienced as engaging and entertaining throughout repeated training sessions on long-duration missions. Consequently, this self-management technology has threefold capability for recreation, behavioral health problem prophylaxis and remediation, and psychophysiological assay. The RESTORE concept aims to reduce the risk of future manned exploration missions by enhancing the capability of individual crewmembers to self-regulate cognitive states through recreation-embedded training protocols to effectively deal with the psychological toll of long-duration space flight.

  19. Bluetooth-based sensor networks for remotely monitoring the physiological signals of a patient.

    PubMed

    Zhang, Ying; Xiao, Hannan

    2009-11-01

    Integrating intelligent medical microsensors into a wireless communication network makes it possible to remotely collect physiological signals of a patient, release the patient from being tethered to monitoring medical instrumentations, and facilitate the patient's early hospital discharge. This can further improve life quality by providing continuous observation without the need of disrupting the patient's normal life, thus reducing the risk of infection significantly, and decreasing the cost of the hospital and the patient. This paper discusses the implementation issues, and describes the overall system architecture of our developed Bluetooth sensor network for patient monitoring and the corresponding heart activity sensors. It also presents our approach to developing the intelligent physiological sensor nodes involving integration of Bluetooth radio technology, hardware and software organization, and our solutions for onboard signal processing.

  20. EPMOSt: An Energy-Efficient Passive Monitoring System for Wireless Sensor Networks

    PubMed Central

    Garcia, Fernando P.; Andrade, Rossana M. C.; Oliveira, Carina T.; de Souza, José Neuman

    2014-01-01

    Monitoring systems are important for debugging and analyzing Wireless Sensor Networks (WSN). In passive monitoring, a monitoring network needs to be deployed in addition to the network to be monitored, named the target network. The monitoring network captures and analyzes packets transmitted by the target network. An energy-efficient passive monitoring system is necessary when we need to monitor a WSN in a real scenario because the lifetime of the monitoring network is extended and, consequently, the target network benefits from the monitoring for a longer time. In this work, we have identified, analyzed and compared the main passive monitoring systems proposed for WSN. During our research, we did not identify any passive monitoring system for WSN that aims to reduce the energy consumption of the monitoring network. Therefore, we propose an Energy-efficient Passive MOnitoring SysTem for WSN named EPMOSt that provides monitoring information using a Simple Network Management Protocol (SNMP) agent. Thus, any management tool that supports the SNMP protocol can be integrated with this monitoring system. Experiments with real sensors were performed in several scenarios. The results obtained show the energy efficiency of the proposed monitoring system and the viability of using it to monitor WSN in real scenarios. PMID:24949639

  1. Validation of the Microlife BP A200 Comfort and W2 Slim automated blood pressure monitors in a general adult population according to the European Society of Hypertension and the ANSI/AAMI/ISO 81060-2: 2013 protocols.

    PubMed

    Bing, Sen; Chen, Kang; Hou, Hong; Zhang, Weijuan; Li, Linyi; Wei, Jiao; Shu, Chang; Wan, Yi

    2016-04-01

    This study aimed to determine the accuracy of the Microlife BP A200 Comfort and W2 Slim automated blood pressure monitors according to the European Society of Hypertension International Protocol revision 2010 and the ANSI/AAMI/ISO 81060-2:2013 protocols. The devices were assessed on 33 participants according to the European Society of Hypertension requirements and were then tested on 85 participants according to the ANSI/AAMI/ISO 81060-2:2013 criteria. Procedures and data analysis were carried out following protocol guidelines precisely. The Microlife BP A200 Comfort and W2 Slim devices passed the criteria of the European Society of Hypertension International Protocol revision 2010 for both systolic blood pressure and diastolic blood pressure. The devices also fulfilled the ANSI/AAMI/ISO 81060-2:2013 criteria, with mean differences of SBP and DPB between the devices and observers of 0.38±5.12 and 0.28±4.29 mmHg for the BP A200 Comfort and 1.01±6.80 and 0.34±5.62 mmHg for the W2 Slim, respectively. The Microlife BP A200 Comfort and W2 Slim automated blood pressure monitors fulfilled the European Society of Hypertension revision 2010 and the ANSI/AAMI/ISO 81060-2:2013 protocols, and can be recommended for self-measurement in the general population.

  2. Space Biosensor Systems: Implications for Technology Transfer

    NASA Technical Reports Server (NTRS)

    Hines, J. W.; Somps, C. J.; Madou, M.; Imprescia, Clifford C. (Technical Monitor)

    1997-01-01

    To meet the need for continuous, automated monitoring of animal subjects, including; humans, during space flight, NASA is developing advanced physiologic sensor and biotelemetry system technologies. The ability to continuously track basic physiological parameters, such as heart rate, blood pH, and body temperature, in untethered subjects in space is a challenging task. At NASA's Ames Research Center, where a key focus is gravitational biology research, engineers have teamed with life scientists to develop wireless sensor systems for automated physiologic monitoring of animal models as small as the rat. This technology is also being adapted, in collaboration with medical professionals, to meet human clinical monitoring needs both in space and on the ground. Thus, these advanced monitoring technologies have important dual-use functions; they meet space flight data collection requirements and constraints, while concurrently addressing a number of monitoring and data acquisition challenges on the ground in areas of clinical monitoring and biomedical research. Additional applications for these and related technologies are being sought and additional partnerships established that enhance development efforts, reduce costs and facilitate technology infusion between the public and private sectors. This paper describes technology transfer and co-development projects that have evolved out of NASA's miniaturized, implantable chemical sensor development efforts.

  3. How consumer physical activity monitors could transform human physiology research.

    PubMed

    Wright, Stephen P; Hall Brown, Tyish S; Collier, Scott R; Sandberg, Kathryn

    2017-03-01

    A sedentary lifestyle and lack of physical activity are well-established risk factors for chronic disease and adverse health outcomes. Thus, there is enormous interest in measuring physical activity in biomedical research. Many consumer physical activity monitors, including Basis Health Tracker, BodyMedia Fit, DirectLife, Fitbit Flex, Fitbit One, Fitbit Zip, Garmin Vivofit, Jawbone UP, MisFit Shine, Nike FuelBand, Polar Loop, Withings Pulse O 2 , and others have accuracies similar to that of research-grade physical activity monitors for measuring steps. This review focuses on the unprecedented opportunities that consumer physical activity monitors offer for human physiology and pathophysiology research because of their ability to measure activity continuously under real-life conditions and because they are already widely used by consumers. We examine current and potential uses of consumer physical activity monitors as a measuring or monitoring device, or as an intervention in strategies to change behavior and predict health outcomes. The accuracy, reliability, reproducibility, and validity of consumer physical activity monitors are reviewed, as are limitations and challenges associated with using these devices in research. Other topics covered include how smartphone apps and platforms, such as the Apple ResearchKit, can be used in conjunction with consumer physical activity monitors for research. Lastly, the future of consumer physical activity monitors and related technology is considered: pattern recognition, integration of sleep monitors, and other biosensors in combination with new forms of information processing. Copyright © 2017 the American Physiological Society.

  4. 21 CFR 868.2377 - Apnea monitor.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... breath. The apnea monitor also includes indirect methods of apnea detection such as monitoring of heart rate and other physiological parameters linked to the presence or absence of adequate respiration. (b...

  5. 21 CFR 868.2377 - Apnea monitor.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... breath. The apnea monitor also includes indirect methods of apnea detection such as monitoring of heart rate and other physiological parameters linked to the presence or absence of adequate respiration. (b...

  6. 21 CFR 868.2377 - Apnea monitor.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... breath. The apnea monitor also includes indirect methods of apnea detection such as monitoring of heart rate and other physiological parameters linked to the presence or absence of adequate respiration. (b...

  7. 21 CFR 868.2377 - Apnea monitor.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... breath. The apnea monitor also includes indirect methods of apnea detection such as monitoring of heart rate and other physiological parameters linked to the presence or absence of adequate respiration. (b...

  8. 21 CFR 868.2377 - Apnea monitor.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... breath. The apnea monitor also includes indirect methods of apnea detection such as monitoring of heart rate and other physiological parameters linked to the presence or absence of adequate respiration. (b...

  9. Glucose Sensing for Diabetes Monitoring: Recent Developments

    PubMed Central

    Bruen, Danielle; Delaney, Colm; Florea, Larisa

    2017-01-01

    This review highlights recent advances towards non-invasive and continuous glucose monitoring devices, with a particular focus placed on monitoring glucose concentrations in alternative physiological fluids to blood. PMID:28805693

  10. Review of Quantitative Monitoring Methodologies for Emissions Verification and Accounting for Carbon Dioxide Capture and Storage for California’s Greenhouse Gas Cap-and-Trade and Low-Carbon Fuel Standard Programs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Oldenburg, Curtis M.; Birkholzer, Jens T.

    The Cap-and-Trade and Low Carbon Fuel Standard (LCFS) programs being administered by the California Air Resources Board (CARB) include Carbon Dioxide Capture and Storage (CCS) as a potential means to reduce greenhouse gas (GHG) emissions. However, there is currently no universal standard approach that quantifies GHG emissions reductions for CCS and that is suitable for the quantitative needs of the Cap-and-Trade and LCFS programs. CCS involves emissions related to the capture (e.g., arising from increased energy needed to separate carbon dioxide (CO 2) from a flue gas and compress it for transport), transport (e.g., by pipeline), and storage of COmore » 2 (e.g., due to leakage to the atmosphere from geologic CO 2 storage sites). In this project, we reviewed and compared monitoring, verification, and accounting (MVA) protocols for CCS from around the world by focusing on protocols specific to the geologic storage part of CCS. In addition to presenting the review of these protocols, we highlight in this report those storage-related MVA protocols that we believe are particularly appropriate for CCS in California. We find that none of the existing protocols is completely appropriate for California, but various elements of all of them could be adopted and/or augmented to develop a rigorous, defensible, and practical surface leakage MVA protocol for California. The key features of a suitable surface leakage MVA plan for California are that it: (1) informs and validates the leakage risk assessment, (2) specifies use of the most effective monitoring strategies while still being flexible enough to accommodate special or site-specific conditions, (3) quantifies stored CO 2, and (4) offers defensible estimates of uncertainty in monitored properties. California’s surface leakage MVA protocol needs to be applicable to the main CO 2 storage opportunities (in California and in other states with entities participating in California’s Cap-and-Trade or LCFS programs), specifically CO 2-enhanced oil recovery (CO 2-EOR), CO 2 injection into depleted gas reservoirs (with or without CO 2-enhanced gas recovery (CO 2-EGR)), as well as deep saline storage. Regarding the elements of an effective surface leakage MVA protocol, our recommendations for California are that: (1) both CO 2 and methane (CH 4) surface leakage should be monitored, especially for enhanced recovery scenarios, (2) emissions from all sources not directly related to injection and geologic storage (e.g., from capture, or pipeline transport) should be monitored and reported under a plan separate from the surface leakage MVA plan that is included as another component of the quantification methodology (QM), (3) the primary objective of the surface leakage MVA plan should be to quantify surface leakage of CO 2 and CH 4 and its uncertainty, with consideration of best-practices and state-of-the-art approaches to monitoring including attribution assessment, (4) effort should be made to monitor CO 2 storage and migration in the subsurface to anticipate future surface leakage monitoring needs, (5) detailed descriptions of specific monitoring technologies and approaches should be provided in the MVA plan, (6) the main purpose of the CO 2 injection project (CO 2-EOR, CO 2-EGR, or pure geologic carbon sequestration (GCS)) needs to be stated up front, (7) approaches to dealing with missing data and quantifying uncertainty need to be described, and (8) post-injection monitoring should go on for a period consistent with or longer than that prescribed by the U.S. EPA.« less

  11. Vital Recorder-a free research tool for automatic recording of high-resolution time-synchronised physiological data from multiple anaesthesia devices.

    PubMed

    Lee, Hyung-Chul; Jung, Chul-Woo

    2018-01-24

    The current anaesthesia information management system (AIMS) has limited capability for the acquisition of high-quality vital signs data. We have developed a Vital Recorder program to overcome the disadvantages of AIMS and to support research. Physiological data of surgical patients were collected from 10 operating rooms using the Vital Recorder. The basic equipment used were a patient monitor, the anaesthesia machine, and the bispectral index (BIS) monitor. Infusion pumps, cardiac output monitors, regional oximeter, and rapid infusion device were added as required. The automatic recording option was used exclusively and the status of recording was frequently checked through web monitoring. Automatic recording was successful in 98.5% (4,272/4,335) cases during eight months of operation. The total recorded time was 13,489 h (3.2 ± 1.9 h/case). The Vital Recorder's automatic recording and remote monitoring capabilities enabled us to record physiological big data with minimal effort. The Vital Recorder also provided time-synchronised data captured from a variety of devices to facilitate an integrated analysis of vital signs data. The free distribution of the Vital Recorder is expected to improve data access for researchers attempting physiological data studies and to eliminate inequalities in research opportunities due to differences in data collection capabilities.

  12. A Practical and Time-Efficient High-Intensity Interval Training Program Modifies Cardio-Metabolic Risk Factors in Adults with Risk Factors for Type II Diabetes.

    PubMed

    Phillips, Bethan E; Kelly, Benjamin M; Lilja, Mats; Ponce-González, Jesús Gustavo; Brogan, Robert J; Morris, David L; Gustafsson, Thomas; Kraus, William E; Atherton, Philip J; Vollaard, Niels B J; Rooyackers, Olav; Timmons, James A

    2017-01-01

    Regular physical activity (PA) can reduce the risk of developing type 2 diabetes, but adherence to time-orientated (150 min week -1 or more) PA guidelines is very poor. A practical and time-efficient PA regime that was equally efficacious at controlling risk factors for cardio-metabolic disease is one solution to this problem. Herein, we evaluate a new time-efficient and genuinely practical high-intensity interval training (HIT) protocol in men and women with pre-existing risk factors for type 2 diabetes. One hundred eighty-nine sedentary women ( n  = 101) and men ( n  = 88) with impaired glucose tolerance and/or a body mass index >27 kg m -2 [mean (range) age: 36 (18-53) years] participated in this multi-center study. Each completed a fully supervised 6-week HIT protocol at work-loads equivalent to ~100 or ~125% [Formula: see text]. Change in [Formula: see text] was used to monitor protocol efficacy, while Actiheart™ monitors were used to determine PA during four, weeklong, periods. Mean arterial (blood) pressure (MAP) and fasting insulin resistance [homeostatic model assessment (HOMA)-IR] represent key health biomarker outcomes. The higher intensity bouts (~125% [Formula: see text]) used during a 5-by-1 min HIT protocol resulted in a robust increase in [Formula: see text] (136 participants, +10.0%, p  < 0.001; large size effect). 5-by-1 HIT reduced MAP (~3%; p  < 0.001) and HOMA-IR (~16%; p  < 0.01). Physiological responses were similar in men and women while a sizeable proportion of the training-induced changes in [Formula: see text], MAP, and HOMA-IR was retained 3 weeks after cessation of training. The supervised HIT sessions accounted for the entire quantifiable increase in PA, and this equated to 400 metabolic equivalent (MET) min week -1 . Meta-analysis indicated that 5-by-1 HIT matched the efficacy and variability of a time-consuming 30-week PA program on [Formula: see text], MAP, and HOMA-IR. With a total time-commitment of <15 min per session and reliance on a practical ergometer protocol, 5-by-1 HIT offers a new solution to modulate cardio-metabolic risk factors in adults with pre-existing risk factors for type 2 diabetes while approximately meeting the MET min week -1 PA guidelines. Long-term randomized controlled studies will be required to quantify the ability for 5-by-1 HIT to reduce the incidence of type 2 diabetes, while strategies are required to harmonize the adaptations to exercise across individuals.

  13. A Wireless Physiological Signal Monitoring System with Integrated Bluetooth and WiFi Technologies.

    PubMed

    Yu, Sung-Nien; Cheng, Jen-Chieh

    2005-01-01

    This paper proposes a wireless patient monitoring system which integrates Bluetooth and WiFi wireless technologies. A wireless portable multi-parameter device was designated to acquire physiological signals and transmit them to a local server via Bluetooth wireless technology. Four kinds of monitor units were designed to communicate via the WiFi wireless technology, including a local monitor unit, a control center, mobile devices (personal digital assistant; PDA), and a web page. The use of various monitor units is intending to meet different medical requirements for different medical personnel. This system was demonstrated to promote the mobility and flexibility for both the patients and the medical personnel, which further improves the quality of health care.

  14. Quantifiable long-term monitoring on parks and nature preserves

    USGS Publications Warehouse

    Beck, Scott; Moorman, Christopher; DePerno, Christopher S.; Simons, Theodore R.

    2013-01-01

    Herpetofauna have declined globally, and monitoring is a useful approach to document local and long-term changes. However, monitoring efforts often fail to account for detectability or follow standardized protocols. We performed a case study at Hemlock Bluffs Nature Preserve in Cary, NC to model occupancy of focal species and demonstrate a replicable long-term protocol useful to parks and nature preserves. From March 2010 to 2011, we documented occupancy of Ambystoma opacum(Marbled Salamander), Plethodon cinereus (Red-backed Salamander), Carphophis amoenus (Eastern Worm Snake), and Diadophis punctatus (Ringneck Snake) at coverboard sites and estimated breeding female Ambystoma maculatum (Spotted Salamander) abundance via dependent double-observer egg-mass counts in ephemeral pools. Temperature influenced detection of both Marbled and Red-backed Salamanders. Based on egg-mass data, we estimated Spotted Salamander abundance to be between 21 and 44 breeding females. We detected 43 of 53 previously documented herpetofauna species. Our approach demonstrates a monitoring protocol that accounts for factors that influence species detection and is replicable by parks or nature preserves with limited resources.

  15. Three-dimensional quantitative T1 and T2 mapping of the carotid artery: Sequence design and in vivo feasibility.

    PubMed

    Coolen, Bram F; Poot, Dirk H J; Liem, Madieke I; Smits, Loek P; Gao, Shan; Kotek, Gyula; Klein, Stefan; Nederveen, Aart J

    2016-03-01

    A novel three-dimensional (3D) T1 and T2 mapping protocol for the carotid artery is presented. A 3D black-blood imaging sequence was adapted allowing carotid T1 and T2 mapping using multiple flip angles and echo time (TE) preparation times. B1 mapping was performed to correct for spatially varying deviations from the nominal flip angle. The protocol was optimized using simulations and phantom experiments. In vivo scans were performed on six healthy volunteers in two sessions, and in a patient with advanced atherosclerosis. Compensation for patient motion was achieved by 3D registration of the inter/intrasession scans. Subsequently, T1 and T2 maps were obtained by maximum likelihood estimation. Simulations and phantom experiments showed that the bias in T1 and T2 estimation was < 10% within the range of physiological values. In vivo T1 and T2 values for carotid vessel wall were 844 ± 96 and 39 ± 5 ms, with good repeatability across scans. Patient data revealed altered T1 and T2 values in regions of atherosclerotic plaque. The 3D T1 and T2 mapping of the carotid artery is feasible using variable flip angle and variable TE preparation acquisitions. We foresee application of this technique for plaque characterization and monitoring plaque progression in atherosclerotic patients. © 2015 Wiley Periodicals, Inc.

  16. Modulation of Total Sleep Time by Transcranial Direct Current Stimulation (tDCS).

    PubMed

    Frase, Lukas; Piosczyk, Hannah; Zittel, Sulamith; Jahn, Friederike; Selhausen, Peter; Krone, Lukas; Feige, Bernd; Mainberger, Florian; Maier, Jonathan G; Kuhn, Marion; Klöppel, Stefan; Normann, Claus; Sterr, Annette; Spiegelhalder, Kai; Riemann, Dieter; Nitsche, Michael A; Nissen, Christoph

    2016-09-01

    Arousal and sleep are fundamental physiological processes, and their modulation is of high clinical significance. This study tested the hypothesis that total sleep time (TST) in humans can be modulated by the non-invasive brain stimulation technique transcranial direct current stimulation (tDCS) targeting a 'top-down' cortico-thalamic pathway of sleep-wake regulation. Nineteen healthy participants underwent a within-subject, repeated-measures protocol across five nights in the sleep laboratory with polysomnographic monitoring (adaptation, baseline, three experimental nights). tDCS was delivered via bi-frontal target electrodes and bi-parietal return electrodes before sleep (anodal 'activation', cathodal 'deactivation', and sham stimulation). Bi-frontal anodal stimulation significantly decreased TST, compared with cathodal and sham stimulation. This effect was location specific. Bi-frontal cathodal stimulation did not significantly increase TST, potentially due to ceiling effects in good sleepers. Exploratory resting-state EEG analyses before and after the tDCS protocols were consistent with the notion of increased cortical arousal after anodal stimulation and decreased cortical arousal after cathodal stimulation. The study provides proof-of-concept that TST can be decreased by non-invasive bi-frontal anodal tDCS in healthy humans. Further elucidating the 'top-down' pathway of sleep-wake regulation is expected to increase knowledge on the fundamentals of sleep-wake regulation and to contribute to the development of novel treatments for clinical conditions of disturbed arousal and sleep.

  17. Modulation of Total Sleep Time by Transcranial Direct Current Stimulation (tDCS)

    PubMed Central

    Frase, Lukas; Piosczyk, Hannah; Zittel, Sulamith; Jahn, Friederike; Selhausen, Peter; Krone, Lukas; Feige, Bernd; Mainberger, Florian; Maier, Jonathan G; Kuhn, Marion; Klöppel, Stefan; Normann, Claus; Sterr, Annette; Spiegelhalder, Kai; Riemann, Dieter; Nitsche, Michael A; Nissen, Christoph

    2016-01-01

    Arousal and sleep are fundamental physiological processes, and their modulation is of high clinical significance. This study tested the hypothesis that total sleep time (TST) in humans can be modulated by the non-invasive brain stimulation technique transcranial direct current stimulation (tDCS) targeting a ‘top-down' cortico-thalamic pathway of sleep-wake regulation. Nineteen healthy participants underwent a within-subject, repeated-measures protocol across five nights in the sleep laboratory with polysomnographic monitoring (adaptation, baseline, three experimental nights). tDCS was delivered via bi-frontal target electrodes and bi-parietal return electrodes before sleep (anodal ‘activation', cathodal ‘deactivation', and sham stimulation). Bi-frontal anodal stimulation significantly decreased TST, compared with cathodal and sham stimulation. This effect was location specific. Bi-frontal cathodal stimulation did not significantly increase TST, potentially due to ceiling effects in good sleepers. Exploratory resting-state EEG analyses before and after the tDCS protocols were consistent with the notion of increased cortical arousal after anodal stimulation and decreased cortical arousal after cathodal stimulation. The study provides proof-of-concept that TST can be decreased by non-invasive bi-frontal anodal tDCS in healthy humans. Further elucidating the ‘top-down' pathway of sleep-wake regulation is expected to increase knowledge on the fundamentals of sleep-wake regulation and to contribute to the development of novel treatments for clinical conditions of disturbed arousal and sleep. PMID:27143601

  18. SPP: A data base processor data communications protocol

    NASA Technical Reports Server (NTRS)

    Fishwick, P. A.

    1983-01-01

    The design and implementation of a data communications protocol for the Intel Data Base Processor (DBP) is defined. The protocol is termed SPP (Service Port Protocol) since it enables data transfer between the host computer and the DBP service port. The protocol implementation is extensible in that it is explicitly layered and the protocol functionality is hierarchically organized. Extensive trace and performance capabilities have been supplied with the protocol software to permit optional efficient monitoring of the data transfer between the host and the Intel data base processor. Machine independence was considered to be an important attribute during the design and implementation of SPP. The protocol source is fully commented and is included in Appendix A of this report.

  19. Protocol Gas Verification Program Audit Reports

    EPA Pesticide Factsheets

    View the full reports from 2010 and 2013 of the PGVP audits, which tested the EPA Protocol gases that are used to calibrate continuous emission monitoring systems (CEMS), and the instruments used in EPA reference methods.

  20. PNNI Performance Validation Test Report

    NASA Technical Reports Server (NTRS)

    Dimond, Robert P.

    1999-01-01

    Two Private Network-Network Interface (PNNI) neighboring peers were monitored with a protocol analyzer to understand and document how PNNI works with regards to initialization and recovery processes. With the processes documented, pertinent events were found and measured to determine the protocols behavior in several environments, which consisted of congestion and/or delay. Subsequent testing of the protocol in these environments was conducted to determine the protocol's suitability for use in satellite-terrestrial network architectures.

  1. Hemodynamic and neuro-monitoring for neurocritically ill patients: An international survey of intensivists.

    PubMed

    Sivakumar, Sanjeev; Taccone, Fabio S; Rehman, Mohammed; Hinson, Holly; Naval, Neeraj; Lazaridis, Christos

    2017-06-01

    To investigate multimodality systemic and neuro-monitoring practices in acute brain injury (ABI) and to analyze differences among "neurointensivists" (NI; clinical practice comprised >1/3 by neurocritical care), and other intensivists (OI). Anonymous 22-question Web-based survey among physician members of SCCM and ESICM. Six hundred fifty-five responded (66% completion rate); 422 (65%) were OI, and 226 (35%) were NI. More NI follow hemodynamic protocols for TBI (44.5% vs 33%, P=.007) and SAH (38% vs 21%, P<.001). For CPP optimization, NI use more arterial-waveform-analysis (AWA) (45% vs 35%, P=.019), and ultrasound (37.5% vs 28%, P=.023); NI use more PbtO 2 (28% vs 10%, P<.001). In the case scenario of raised ICP/low PbtO 2 , most employ analgesia and/or sedation (47%) and osmotherapy (38%). More NI use pressure reactivity (vasopressor use OI 23% vs NI 34.5%, P=.014). For DCI, more NI target cardiac index (CI) (35% vs 21%, P<.001), and fluid responsiveness (62.5% vs 53%, P=.03). Also, NI use more angiography (57% vs 43.5%, P=.004), TCD (56.5% vs 38%, P<.001), CTP (32% vs16%, P<.001), and PbtO 2 (18% vs 7.5%, P=.001). Intensivists with exposure to ABI patients employ more neuro- and hemodynamic monitoring. We found large heterogeneity and low overall use of advanced brain-physiology parameters. Copyright © 2017 Elsevier Inc. All rights reserved.

  2. A comparative study of routing protocols of heterogeneous wireless sensor networks.

    PubMed

    Han, Guangjie; Jiang, Xu; Qian, Aihua; Rodrigues, Joel J P C; Cheng, Long

    2014-01-01

    Recently, heterogeneous wireless sensor network (HWSN) routing protocols have drawn more and more attention. Various HWSN routing protocols have been proposed to improve the performance of HWSNs. Among these protocols, hierarchical HWSN routing protocols can improve the performance of the network significantly. In this paper, we will evaluate three hierarchical HWSN protocols proposed recently--EDFCM, MCR, and EEPCA--together with two previous classical routing protocols--LEACH and SEP. We mainly focus on the round of the first node dies (also called the stable period) and the number of packets sent to sink, which is an important aspect to evaluate the monitoring ability of a protocol. We conduct a lot of experiments and simulations on Matlab to analyze the performance of the five routing protocols.

  3. Design and modelling of a link monitoring mechanism for the Common Data Link (CDL)

    NASA Astrophysics Data System (ADS)

    Eichelberger, John W., III

    1994-09-01

    The Common Data Link (CDL) is a full duplex, point-to-point microwave communications system used in imagery and signals intelligence collection systems. It provides a link between two remote Local Area Networks (LAN's) aboard collection and surface platforms. In a hostile environment, there is an overwhelming need to dynamically monitor the link and thus, limit the impact of jamming. This work describes steps taken to design, model, and evaluate a link monitoring system suitable for the CDL. The monitoring system is based on features and monitoring constructs of the Link Control Protocol (LCP) in the Point-to-Point Protocol (PPP) suite. The CDL model is based on a system of two remote Fiber Distributed Data Interface (FDDI) LAN's. In particular, the policies and mechanisms associated with monitoring are described in detail. An implementation of the required mechanisms using the OPNET network engineering tool is described. Performance data related to monitoring parameters is reported. Finally, integration of the FDDI-CDL model with the OPNET Internet model is described.

  4. The management of Convulsive Refractory Status Epilepticus in adults in the UK: No consistency in practice and little access to continuous EEG monitoring.

    PubMed

    Patel, Mitesh; Bagary, Manny; McCorry, Dougall

    2015-01-01

    Convulsive Status Epilepticus (CSE) is a common neurological emergency with patients presenting with prolonged epileptic activity. Sub-optimal management is coupled with high morbidity and mortality. Continuous electroencephalogram (EEG) monitoring is considered essential by the National Institute for Health and Care Excellence (NICE) in the management of Convulsive Refractory Status Epilepticus (CRSE). The aim of this research was to determine current clinical practice in the management of CRSE amongst adults in intensive care units (ICU) in the UK and establish if the use of a standardised protocol requires re-enforcement within trusts. 75 randomly selected UK NHS Trusts were contacted and asked to complete a questionnaire in addition to providing their protocol for CRSE management in ICU. 55 (73%) trusts responded. While 31 (56% of responders) had a protocol available in ICU for early stages of CSE, just 21 (38%) trusts had specific guidelines if CRSE occurred. Only 23 (42%) trusts involved neurologists at any stage of management and just 18 (33%) have access to continuous EEG monitoring. This study identifies significant inconsistency in the management of CSE in ICU's across the UK. A minority of ICU units have a protocol for CRSE or access to continuous EEG monitoring despite it being considered fundamental for management and supported by NICE guidance. Copyright © 2014 British Epilepsy Association. Published by Elsevier Ltd. All rights reserved.

  5. MultiSense: A Multimodal Sensor Tool Enabling the High-Throughput Analysis of Respiration.

    PubMed

    Keil, Peter; Liebsch, Gregor; Borisjuk, Ljudmilla; Rolletschek, Hardy

    2017-01-01

    The high-throughput analysis of respiratory activity has become an important component of many biological investigations. Here, a technological platform, denoted the "MultiSense tool," is described. The tool enables the parallel monitoring of respiration in 100 samples over an extended time period, by dynamically tracking the concentrations of oxygen (O 2 ) and/or carbon dioxide (CO 2 ) and/or pH within an airtight vial. Its flexible design supports the quantification of respiration based on either oxygen consumption or carbon dioxide release, thereby allowing for the determination of the physiologically significant respiratory quotient (the ratio between the quantities of CO 2 released and the O 2 consumed). It requires an LED light source to be mounted above the sample, together with a CCD camera system, adjusted to enable the capture of analyte-specific wavelengths, and fluorescent sensor spots inserted into the sample vial. Here, a demonstration is given of the use of the MultiSense tool to quantify respiration in imbibing plant seeds, for which an appropriate step-by-step protocol is provided. The technology can be easily adapted for a wide range of applications, including the monitoring of gas exchange in any kind of liquid culture system (algae, embryo and tissue culture, cell suspensions, microbial cultures).

  6. Sinusoidal voltage protocols for rapid characterisation of ion channel kinetics.

    PubMed

    Beattie, Kylie A; Hill, Adam P; Bardenet, Rémi; Cui, Yi; Vandenberg, Jamie I; Gavaghan, David J; de Boer, Teun P; Mirams, Gary R

    2018-03-24

    Ion current kinetics are commonly represented by current-voltage relationships, time constant-voltage relationships and subsequently mathematical models fitted to these. These experiments take substantial time, which means they are rarely performed in the same cell. Rather than traditional square-wave voltage clamps, we fitted a model to the current evoked by a novel sum-of-sinusoids voltage clamp that was only 8 s long. Short protocols that can be performed multiple times within a single cell will offer many new opportunities to measure how ion current kinetics are affected by changing conditions. The new model predicts the current under traditional square-wave protocols well, with better predictions of underlying currents than literature models. The current under a novel physiologically relevant series of action potential clamps is predicted extremely well. The short sinusoidal protocols allow a model to be fully fitted to individual cells, allowing us to examine cell-cell variability in current kinetics for the first time. Understanding the roles of ion currents is crucial to predict the action of pharmaceuticals and mutations in different scenarios, and thereby to guide clinical interventions in the heart, brain and other electrophysiological systems. Our ability to predict how ion currents contribute to cellular electrophysiology is in turn critically dependent on our characterisation of ion channel kinetics - the voltage-dependent rates of transition between open, closed and inactivated channel states. We present a new method for rapidly exploring and characterising ion channel kinetics, applying it to the hERG potassium channel as an example, with the aim of generating a quantitatively predictive representation of the ion current. We fitted a mathematical model to currents evoked by a novel 8 second sinusoidal voltage clamp in CHO cells overexpressing hERG1a. The model was then used to predict over 5 minutes of recordings in the same cell in response to further protocols: a series of traditional square step voltage clamps, and also a novel voltage clamp comprising a collection of physiologically relevant action potentials. We demonstrate that we can make predictive cell-specific models that outperform the use of averaged data from a number of different cells, and thereby examine which changes in gating are responsible for cell-cell variability in current kinetics. Our technique allows rapid collection of consistent and high quality data, from single cells, and produces more predictive mathematical ion channel models than traditional approaches. © 2018 The Authors. The Journal of Physiology published by John Wiley & Sons Ltd on behalf of The Physiological Society.

  7. Ultrasound Imaging of Spine: State of the Art and Utility for Space Flight

    NASA Technical Reports Server (NTRS)

    Sargsyan, Ashot E.; Bouffard, Antonio J.; Garcia, Kathleen; Hamilton, Douglas R.; Van Holsbeeck, Marnix; Ebert, Douglas J. W.; Dulchavsky, Scott A.

    2010-01-01

    Introduction: Ultrasound imaging (sonography) has been increasingly used for both primary diagnosis and monitoring of musculoskeletal injury, including fractures. In certain injuries, sonography has been shown to equal or surpass Magnetic Resonance Imaging in accuracy. Long-term exposure to reduced gravity may be expected to cause physiological and anatomical changes of the musculoskeletal system, which are not fully described or understood. In a limited-resource environment like space flight, sonography will likely remain the only imaging modality; therefore, further attention to its potential is warranted, including its ability to image anatomical deviations as well as irregularities of vertebrae and the spinal column. Methods: A thorough review of literature was conducted on the subject. A multipurpose ultrasound system was used to identify specific vertebrae, intervertebral disks, and other structures of the cervical spine in healthy volunteers, selected to represent various age, gender, and Body Mass Index (BMI) groups. Sonographic views were sought that would parallel radiographic views and signs used in the diagnosis of cervical spine injuries. Results: While using widely accepted radiographic signs of cervical spine injury, this sonographic protocol development effort resulted in successful identification of scanning planes and imaging protocols that could serve as alternatives for radiography. Some of these views are also applicable to diagnosing degenerative disk and bone disease, and other non-traumatic spine pathology. Strong, preliminary correlation has been demonstrated in a number of clinical cases between sonography and other imaging modalities. Conclusion: In the absence of radiography, sonography can be used to diagnose or rule out certain common types of cervical spine conditions including injury. Clinical validation of the findings appears to be realistic and would facilitate establishment of new sonographic protocols for special environments with lacking radiographic capability, such as human space flight.

  8. A Murine Model of Robotic Training to Evaluate Skeletal Muscle Recovery after Injury.

    PubMed

    Lai, Stefano; Panarese, Alessandro; Lawrence, Ross; Boninger, Michael L; Micera, Silvestro; Ambrosio, Fabrisia

    2017-04-01

    In vivo studies have suggested that motor exercise can improve muscle regeneration after injury. Nevertheless, preclinical investigations still lack reliable tools to monitor motor performance over time and to deliver optimal training protocols to maximize force recovery. Here, we evaluated the utility of a murine robotic platform (i) to detect early impairment and longitudinal recovery after acute skeletal muscle injury and (ii) to administer varying intensity training protocols to enhance forelimb motor performance. A custom-designed robotic platform was used to train mice to perform a forelimb retraction task. After an acute injury to bilateral biceps brachii muscles, animals performed a daily training protocol in the platform at high (HL) or low (LL) loading levels over the course of 3 wk. Control animals were not trained (NT). Motor performance was assessed by quantifying force, time, submovement count, and number of movement attempts to accomplish the task. Myofiber number and cross-sectional area at the injury site were quantified histologically. Two days after injury, significant differences in the time, submovement count, number of movement attempts, and exerted force were observed in all mice, as compared with baseline values. Interestingly, the recovery time of muscle force production differed significantly between intervention groups, with HL group showing a significantly accelerated recovery. Three weeks after injury, all groups showed motor performance comparable with baseline values. Accordingly, there were no differences in the number of myofibers or average cross-sectional area among groups after 3 wk. Our findings demonstrate the utility of our custom-designed robotic device for the quantitative assessment of skeletal muscle function in preclinical murine studies. Moreover, we demonstrate that this device may be used to apply varying levels of resistance longitudinally as a means manipulate physiological muscle responses.

  9. Physiological Reactivity in a Community Sample of Sexually Aggressive Young Men: A Test of Competing Hypotheses

    PubMed Central

    Peterson, Zoë D.; Janssen, Erick; Goodrich, David; Heiman, Julia R.

    2015-01-01

    Men’s sexually aggressive behavior potentially could relate to either physiological hyporeactivity or hyperreactivity, and these two different physiological profiles could be associated with different underlying causes of sexual aggression. Thus, measurement of physiological reactivity could provide insight into mechanisms relevant to the etiology of sexual aggression. The relationship between sexual aggression and physiological reactivity was investigated in 78 community men (38 sexually aggressive and 40 non-aggressive men). In a laboratory protocol, the men were exposed to neutral, negative-affect-inducing, and positive-affect-inducing stimuli. Men’s salivary cortisol concentrations and electrodermal activity (EDA) were measured throughout the laboratory procedure. Sexually aggressive men demonstrated (1) lower overall cortisol levels and (2) lower EDA reactivity in some conditions as compared to non-aggressive men. Results of this study were consistent with the idea that men’s sexual aggression is associated with physiological hyporeactivity, a physiological profile that has been found to be associated with externalizing behaviors and psychopathic traits. PMID:24310818

  10. Physiological reactivity in a community sample of sexually aggressive young men: a test of competing hypotheses.

    PubMed

    Peterson, Zoë D; Janssen, Erick; Goodrich, David; Heiman, Julia R

    2014-01-01

    Men's sexually aggressive behavior potentially could relate to either physiological hyporeactivity or hyperreactivity, and these two different physiological profiles could be associated with different underlying causes of sexual aggression. Thus, measurement of physiological reactivity could provide insight into mechanisms relevant to the etiology of sexual aggression. The relationship between sexual aggression and physiological reactivity was investigated in 78 community men (38 sexually aggressive and 40 non-aggressive men). In a laboratory protocol, the men were exposed to neutral, negative-affect-inducing, and positive-affect-inducing stimuli. Men's salivary cortisol concentrations and electrodermal activity (EDA) were measured throughout the laboratory procedure. Sexually aggressive men demonstrated (1) lower overall cortisol levels and (2) lower EDA reactivity in some conditions as compared to non-aggressive men. Results of this study were consistent with the idea that men's sexual aggression is associated with physiological hyporeactivity, a physiological profile that has been found to be associated with externalizing behaviors and psychopathic traits. © 2013 Wiley Periodicals, Inc.

  11. Understanding fetal physiology and second line monitoring during labor.

    PubMed

    Garabedian, C; De Jonckheere, J; Butruille, L; Deruelle, P; Storme, L; Houfflin-Debarge, V

    2017-02-01

    Cardiotocography (CTG) is a technique used to monitor intrapartum fetal condition and is one of the most common obstetric procedures. Second line methods of fetal monitoring have been developed in an attempt to reduce unnecessary interventions due to continuous cardiotocography and to better identify fetuses at risk of intrapartum asphyxia. The acid-base balance of the fetus is evaluated by fetal blood scalp samples, the modification of the myocardial oxygenation by the fetal ECG ST-segment analysis (STAN) and the autonomic nervous system by the power spectral analysis of the fetal heart variability. To correctly interpret the features observed on CTG traces or second line methods, it seems important to understand normal physiology during labor and the compensatory mechanisms of the fetus in case of hypoxemia. Therefore, the aim of this review is first to describe fetal physiology during labor and then to explain the modification of the second line monitoring during labor. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  12. Repetitive Supra-Physiological Shear Stress Impairs Red Blood Cell Deformability and Induces Hemolysis.

    PubMed

    Horobin, Jarod T; Sabapathy, Surendran; Simmonds, Michael J

    2017-11-01

    The supra-physiological shear stress that blood is exposed to while traversing mechanical circulatory assist devices affects the physical properties of red blood cells (RBCs), impairs RBC deformability, and may induce hemolysis. Previous studies exploring RBC damage following exposure to supra-physiological shear stress have employed durations exceeding clinical instrumentation, thus we explored changes in RBC deformability following exposure to shear stress below the reported "hemolytic threshold" using shear exposure durations per minute (i.e., duty-cycles) reflective of that employed by circulatory assist devices. Blood collected from 20 male donors, aged 18-38 years, was suspended in a viscous medium and exposed to an intermittent shear stress protocol of 1 s at 100 Pa, every 60 s for 60 duty-cycles. During the remaining 59 s/min, the cells were left at stasis until the subsequent duty-cycle commenced. At discrete time points (15/30/45/60 duty-cycles), an ektacytometer measured RBC deformability immediately after shear exposure at 100 Pa. Plasma-free hemoglobin, a measurement of hemolysis, was quantified via spectrophotometry. Supra-physiological shear stress impaired RBC properties, as indicated by: (1) decreased maximal elongation of RBCs at infinite shear stress following 15 duty-cycles (P <0.05); (2) increased real-time RBC deformability during application of the supra-physiological shear stress protocol (100 Pa) following exposure to 1 duty-cycle (F (1.891, 32.15) = 12.21, P = 0.0001); and (3) increased plasma-free hemoglobin following 60 duty-cycles (P < 0.01). The present study indicates that exposure of RBCs to short-term, repeated supra-physiological shear stress, impairs RBC deformability, with the extent of impairment exacerbated with each duty-cycle, and ultimately precipitates hemolysis. © 2017 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  13. Regulatory Physiology

    NASA Technical Reports Server (NTRS)

    Lane, Helen W.; Whitson, Peggy A.; Putcha, Lakshmi; Baker, Ellen; Smith, Scott M.; Stewart, Karen; Gretebeck, Randall; Nimmagudda, R. R.; Schoeller, Dale A.; Davis-Street, Janis

    1999-01-01

    As noted elsewhere in this report, a central goal of the Extended Duration Orbiter Medical Project (EDOMP) was to ensure that cardiovascular and muscle function were adequate to perform an emergency egress after 16 days of spaceflight. The goals of the Regulatory Physiology component of the EDOMP were to identify and subsequently ameliorate those biochemical and nutritional factors that deplete physiological reserves or increase risk for disease, and to facilitate the development of effective muscle, exercise, and cardiovascular countermeasures. The component investigations designed to meet these goals focused on biochemical and physiological aspects of nutrition and metabolism, the risk of renal (kidney) stone formation, gastrointestinal function, and sleep in space. Investigations involved both ground-based protocols to validate proposed methods and flight studies to test those methods. Two hardware tests were also completed.

  14. Implementation of an Intensive Care Unit-Specific Alcohol Withdrawal Syndrome Management Protocol Reduces the Need for Mechanical Ventilation.

    PubMed

    Heavner, Jason J; Akgün, Kathleen M; Heavner, Mojdeh S; Eng, Claire C; Drew, Matthew; Jackson, Peter; Pritchard, David; Honiden, Shyoko

    2018-05-25

    Alcohol use disorders are prevalent and put patients at risk for developing alcohol withdrawal syndrome (AWS). Treatment of AWS with a symptom-triggered protocol standardizes management and may avoid AWS-related complications. The objective of this study was to evaluate whether implementation of an intensive care unit (ICU)-specific, symptom-triggered protocol for management of AWS was associated with improved clinical outcomes and, in particular, would reduce the risk of patients with AWS requiring mechanical ventilation. Retrospective pre-post-protocol implementation study. Thirty-six-bed, closed medical ICU (MICU) at a large, tertiary care, teaching hospital in an urban setting. A total of 233 adults admitted to the MICU with any diagnosis of alcohol use disorders based on International Classification of Diseases, Ninth Revision codes and who received at least one dose of any benzodiazepine; of these patients, 139 were in the pre-protocol era (August 2009-January 2010 and August 2010-January 2011), and 94 were in the post-protocol era (August 2012-January 2013), after implementation of the Yale Alcohol Withdrawal Protocol (YAWP) in April 2012. The YAWP pairs a modified Minnesota Detoxification Scale with an order set that includes benzodiazepine dosing regimens and suggests adjuvant therapies. AWS was the primary reason for ICU admission (107/233 patients [45.9%]) and did not significantly vary between eras (P=0.2). Of the 233 patients included, 81.1% were male and 67.0% were white, which did not significantly differ by study era. Severity of illness at MICU admission did not significantly differ between patients in the pre-protocol and post-protocol eras (median [interquartile range] Acute Physiology and Chronic Health Evaluation [APACHE] II scores of 12 [9-17] and 12.5 [7-16], respectively, p=0.4). Median lorazepam-equivalent dose per MICU day, duration of benzodiazepine infusion, and use of adjuvant therapy were not significantly different between eras. MICU intubation was less common in the post-protocol era (36/139 patients [25.9%] pre-protocol vs 8/94 patients [8.5%] post-protocol, p=0.0009). ICU-related pneumonia was also decreased in the post-protocol era (30/139 patients [21.6%] pre-protocol vs 10/94 patients [10.6%] post-protocol, p=0.03). After adjusting for demographics, adjuvant therapies, and Acute Physiology and Chronic Health Evaluation II scores, protocol implementation was associated with a decreased odds of MICU intubation (odds ratio 0.13; 95% confidence interval 0.04-0.39). Implementation of YAWP was associated with a decreased risk of MICU intubation in patients at risk for AWS. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  15. Evaluation of pollutant source strengths and control strategies in an innovative residential high-rise building

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1998-12-31

    Describes a study undertaken to assess the indoor air quality in the Clos St-Andre, a 78-unit residential complex in downtown Montreal, through the implementation of a monitoring protocol in three of the building`s suites; and to examine the relationships between mechanical ventilation, material emissions, occupant lifestyle, and indoor air pollutant concentrations. The monitoring protocol consisted of tracer gas, air exchange testing, material emission testing, airtightness testing, and the monitoring of air temperature, relative humidity, carbon dioxide, carbon monoxide, formaldehyde, and total volatile organic carbon in the suites. Trends in pollutant concentrations over time in the post-construction period are noted.

  16. Validation of the BPLab(®) 24-hour blood pressure monitoring system according to the European standard BS EN 1060-4:2004 and British Hypertension Society protocol.

    PubMed

    Koudryavtcev, Sergey A; Lazarev, Vyacheslav M

    2011-01-01

    Automatic blood pressure (BP) measuring devices are more and more often used in BP self-checks and in 24-hour BP monitoring. Nowadays, 24-hour BP monitoring is a necessary procedure in arterial hypertension treatment. The aim of this study was to validate the BPLab(®) ambulatory blood pressure monitor according to the European standard BS EN 1060-4:2004 and the British Hypertension Society (BHS) protocol, as well as to work out solutions regarding the suitability of using this device in clinical practice. A group of 85 patients of both sexes and different ages, who voluntarily agreed to take part in the tests and were given detailed instructions on the measurement technique were recruited for this study. The results of the BP measurement obtained by a qualified operator using the BPLab(®) device were compared with the BP values measured using the Korotkov auscultatory method. Data were obtained simultaneously by two experts with experience of over 10 years and had completed a noninvasive BP measurement standardization training course. Discrepancies in the systolic and diastolic BP measurements (N = 510; 255 for each expert) were analyzed according to the criteria specified in the BHS-93 protocol. The device passed the requirements of the European Standard BS EN 1060-4:2004 and was graded 'A' according to the criteria of the BHS protocol for both systolic BP and diastolic BP. The BPLab(®) 24-hour ambulatory blood pressure monitoring device may be recommended for extensive clinical use.

  17. Patient Characterization Protocols for Psychophysiological Studies of Traumatic Brain Injury and Post-TBI Psychiatric Disorders

    PubMed Central

    Rapp, Paul E.; Rosenberg, Brenna M.; Keyser, David O.; Nathan, Dominic; Toruno, Kevin M.; Cellucci, Christopher J.; Albano, Alfonso M.; Wylie, Scott A.; Gibson, Douglas; Gilpin, Adele M. K.; Bashore, Theodore R.

    2013-01-01

    Psychophysiological investigations of traumatic brain injury (TBI) are being conducted for several reasons, including the objective of learning more about the underlying physiological mechanisms of the pathological processes that can be initiated by a head injury. Additional goals include the development of objective physiologically based measures that can be used to monitor the response to treatment and to identify minimally symptomatic individuals who are at risk of delayed-onset neuropsychiatric disorders following injury. Research programs studying TBI search for relationships between psychophysiological measures, particularly ERP (event-related potential) component properties (e.g., timing, amplitude, scalp distribution), and a participant’s clinical condition. Moreover, the complex relationships between brain injury and psychiatric disorders are receiving increased research attention, and ERP technologies are making contributions to this effort. This review has two objectives supporting such research efforts. The first is to review evidence indicating that TBI is a significant risk factor for post-injury neuropsychiatric disorders. The second objective is to introduce ERP researchers who are not familiar with neuropsychiatric assessment to the instruments that are available for characterizing TBI, post-concussion syndrome, and psychiatric disorders. Specific recommendations within this very large literature are made. We have proceeded on the assumption that, as is typically the case in an ERP laboratory, the investigators are not clinically qualified and that they will not have access to participant medical records. PMID:23885250

  18. Methodology for quantitative rapid multi-tracer PET tumor characterizations.

    PubMed

    Kadrmas, Dan J; Hoffman, John M

    2013-10-04

    Positron emission tomography (PET) can image a wide variety of functional and physiological parameters in vivo using different radiotracers. As more is learned about the molecular basis for disease and treatment, the potential value of molecular imaging for characterizing and monitoring disease status has increased. Characterizing multiple aspects of tumor physiology by imaging multiple PET tracers in a single patient provides additional complementary information, and there is a significant body of literature supporting the potential value of multi-tracer PET imaging in oncology. However, imaging multiple PET tracers in a single patient presents a number of challenges. A number of techniques are under development for rapidly imaging multiple PET tracers in a single scan, where signal-recovery processing algorithms are employed to recover various imaging endpoints for each tracer. Dynamic imaging is generally used with tracer injections staggered in time, and kinetic constraints are utilized to estimate each tracers' contribution to the multi-tracer imaging signal. This article summarizes past and ongoing work in multi-tracer PET tumor imaging, and then organizes and describes the main algorithmic approaches for achieving multi-tracer PET signal-recovery. While significant advances have been made, the complexity of the approach necessitates protocol design, optimization, and testing for each particular tracer combination and application. Rapid multi-tracer PET techniques have great potential for both research and clinical cancer imaging applications, and continued research in this area is warranted.

  19. Methodology for Quantitative Rapid Multi-Tracer PET Tumor Characterizations

    PubMed Central

    Kadrmas, Dan J.; Hoffman, John M.

    2013-01-01

    Positron emission tomography (PET) can image a wide variety of functional and physiological parameters in vivo using different radiotracers. As more is learned about the molecular basis for disease and treatment, the potential value of molecular imaging for characterizing and monitoring disease status has increased. Characterizing multiple aspects of tumor physiology by imaging multiple PET tracers in a single patient provides additional complementary information, and there is a significant body of literature supporting the potential value of multi-tracer PET imaging in oncology. However, imaging multiple PET tracers in a single patient presents a number of challenges. A number of techniques are under development for rapidly imaging multiple PET tracers in a single scan, where signal-recovery processing algorithms are employed to recover various imaging endpoints for each tracer. Dynamic imaging is generally used with tracer injections staggered in time, and kinetic constraints are utilized to estimate each tracers' contribution to the multi-tracer imaging signal. This article summarizes past and ongoing work in multi-tracer PET tumor imaging, and then organizes and describes the main algorithmic approaches for achieving multi-tracer PET signal-recovery. While significant advances have been made, the complexity of the approach necessitates protocol design, optimization, and testing for each particular tracer combination and application. Rapid multi-tracer PET techniques have great potential for both research and clinical cancer imaging applications, and continued research in this area is warranted. PMID:24312149

  20. The use of real-time optical feedback to improve outcomes

    NASA Astrophysics Data System (ADS)

    Magaña, Isidro B.; Adhikari, Pratik; Yendluri, Raghuvara B.; Goodrich, Glenn P.; Schwartz, Jon A.; O'Neal, D. P.

    2014-03-01

    More than a decade into the development of gold nanoparticles for cancer therapies, with multiple clinical trials underway, ongoing pre-clinical research continues towards better understanding in vivo interactions with the goal of treatment optimization through improved best practices. In an effort to collect information for healthcare providers, enabling informed decisions in a relevant time frame, instrumentation for real-time plasma concentration (multi-wavelength pulse photometry) and protocols for rapid elemental analysis (energy dispersive X-Ray fluorescence) of biopsied tumor tissue have been developed in a murine model. An initial analysis, designed to demonstrate the robust nature and utility of the techniques, revealed that area under the bioavailability curve (AUC) alone does not currently inform tumor accumulation with a high degree of accuracy (R2=0.32), This finding suggests that the control of additional experimental and physiological variables may yield more predictable tumor accumulation. Subject core temperature are blood pressure were monitored, but did not demonstrate clear trends. An effort to modulate AUC has produced an adjuvant therapy which is employed to enhance circulation parameters, including the AUC, of nanorods and gold nanoshells. Preliminary studies demonstrated a greater than 300% increase in average AUC through the use of a reticuloendothelial blockade agent versus control groups. Given a better understanding of the relative importance of the physiological factors which impact rates of tumor accumulation, a proposed set of experimental best practices is presented.

  1. Cardiovascular studies using the chimpanzee (Pan troglodytes)

    NASA Technical Reports Server (NTRS)

    Hinds, J. E.; Cothran, L. N.; Hawthorne, E. W.

    1977-01-01

    Despite the phylogenetic similarities between chimpanzees and man, there exists a paucity of reliable data on normal cardiovascular function and the physiological responses of the system to standard interventions. Totally implanted biotelemetry systems or hardwire analog techniques were used to examine the maximum number of cardiovascular variables which could be simultaneously monitored without significantly altering the system's performance. This was performed in order to acquire base-line data not previously obtained in this species, to determine cardiovascular response to specific forcing functions such as ventricular pacing, drug infusions, and lower body negative pressure. A cardiovascular function profile protocol was developed in order to adjust independently the three major factors which modify ventricular performance, namely, left ventricular performance, left ventricular preload, afterload, and contractility. Cardiac pacing at three levels above the ambient rate was used to adjust end diastolic volume (preload). Three concentrations of angiotensin were infused continuously to evaluate afterload in a stepwide fashion. A continuous infusion of dobutamine was administered to raise the manifest contractile state of the heart.

  2. Behavioral Phenotyping of Murine Disease Models with the Integrated Behavioral Station (INBEST).

    PubMed

    Sakic, Boris; Cooper, Marcella P A; Taylor, Sarah E; Stojanovic, Milica; Zagorac, Bosa; Kapadia, Minesh

    2015-04-23

    Due to rapid advances in genetic engineering, small rodents have become the preferred subjects in many disciplines of biomedical research. In studies of chronic CNS disorders, there is an increasing demand for murine models with high validity at the behavioral level. However, multiple pathogenic mechanisms and complex functional deficits often impose challenges to reliably measure and interpret behavior of chronically sick mice. Therefore, the assessment of peripheral pathology and a behavioral profile at several time points using a battery of tests are required. Video-tracking, behavioral spectroscopy, and remote acquisition of physiological measures are emerging technologies that allow for comprehensive, accurate, and unbiased behavioral analysis in a home-base-like setting. This report describes a refined phenotyping protocol, which includes a custom-made monitoring apparatus (Integrated Behavioral Station, INBEST) that focuses on prolonged measurements of basic functional outputs, such as spontaneous activity, food/water intake and motivated behavior in a relatively stress-free environment. Technical and conceptual improvements in INBEST design may further promote reproducibility and standardization of behavioral studies.

  3. Proposal for study on IR light and glucose phantom interaction for human glucose quantification applications

    NASA Astrophysics Data System (ADS)

    Romo-Cárdenas, Gerardo S.; Sanchez-Lopez, Juan D.; Nieto-Hipolito, Juan I.; Cosio-León, María.; Luque-Morales, Priscy; Vazquez-Briseno, Mabel

    2016-09-01

    It has been established the importance of a constant glucose monitoring in order to keep a regular control for diabetes patients. Several medical studies accept the necessity of exploring alternatives for the traditional digital glucometer, given the pain and discomfort related to this technique, which can lead to a compromised control of the disease. Several efforts based on the application of IR spectroscopy had been done with favorable, yet not conclusive results. Therefore it's necessary to apply a comprehensive and interdisciplinary study based on the biochemical and optical properties of the glucose in the human body, in order to understand the interaction between this substance, its surroundings and IR light. These study propose a comprehensive approach of the glucose and IR light interaction, considering and combining important biochemical, physiological and optical properties, as well as some machine learning techniques for the data analysis. The results of this work would help to define the right parameters aiming to obtain an optical glucose quantification system and protocol.

  4. Generation of Regionally Specific Neural Progenitor Cells (NPCs) and Neurons from Human Pluripotent Stem Cells (hPSCs).

    PubMed

    Cutts, Josh; Brookhouser, Nicholas; Brafman, David A

    2016-01-01

    Neural progenitor cells (NPCs) derived from human pluripotent stem cells (hPSCs) are a multipotent cell population capable of long-term expansion and differentiation into a variety of neuronal subtypes. As such, NPCs have tremendous potential for disease modeling, drug screening, and regenerative medicine. Current methods for the generation of NPCs results in cell populations homogenous for pan-neural markers such as SOX1 and SOX2 but heterogeneous with respect to regional identity. In order to use NPCs and their neuronal derivatives to investigate mechanisms of neurological disorders and develop more physiologically relevant disease models, methods for generation of regionally specific NPCs and neurons are needed. Here, we describe a protocol in which exogenous manipulation of WNT signaling, through either activation or inhibition, during neural differentiation of hPSCs, promotes the formation of regionally homogenous NPCs and neuronal cultures. In addition, we provide methods to monitor and characterize the efficiency of hPSC differentiation to these regionally specific cell identities.

  5. Provably Secure Heterogeneous Access Control Scheme for Wireless Body Area Network.

    PubMed

    Omala, Anyembe Andrew; Mbandu, Angolo Shem; Mutiria, Kamenyi Domenic; Jin, Chunhua; Li, Fagen

    2018-04-28

    Wireless body area network (WBAN) provides a medium through which physiological information could be harvested and transmitted to application provider (AP) in real time. Integrating WBAN in a heterogeneous Internet of Things (IoT) ecosystem would enable an AP to monitor patients from anywhere and at anytime. However, the IoT roadmap of interconnected 'Things' is still faced with many challenges. One of the challenges in healthcare is security and privacy of streamed medical data from heterogeneously networked devices. In this paper, we first propose a heterogeneous signcryption scheme where a sender is in a certificateless cryptographic (CLC) environment while a receiver is in identity-based cryptographic (IBC) environment. We then use this scheme to design a heterogeneous access control protocol. Formal security proof for indistinguishability against adaptive chosen ciphertext attack and unforgeability against adaptive chosen message attack in random oracle model is presented. In comparison with some of the existing access control schemes, our scheme has lower computation and communication cost.

  6. Wearable medical systems for p-Health.

    PubMed

    Teng, Xiao-Fei; Zhang, Yuan-Ting; Poon, Carmen C Y; Bonato, Paolo

    2008-01-01

    Driven by the growing aging population, prevalence of chronic diseases, and continuously rising healthcare costs, the healthcare system is undergoing a fundamental transformation, from the conventional hospital-centered system to an individual-centered system. Current and emerging developments in wearable medical systems will have a radical impact on this paradigm shift. Advances in wearable medical systems will enable the accessibility and affordability of healthcare, so that physiological conditions can be monitored not only at sporadic snapshots but also continuously for extended periods of time, making early disease detection and timely response to health threats possible. This paper reviews recent developments in the area of wearable medical systems for p-Health. Enabling technologies for continuous and noninvasive measurements of vital signs and biochemical variables, advances in intelligent biomedical clothing and body area networks, approaches for motion artifact reduction, strategies for wearable energy harvesting, and the establishment of standard protocols for the evaluation of wearable medical devices are presented in this paper with examples of clinical applications of these technologies.

  7. Interdisciplinary approach to neurocritical care in the intensive care nursery.

    PubMed

    Glass, Hannah C; Rogers, Elizabeth E; Peloquin, Susan; Bonifacio, Sonia L

    2014-12-01

    Neurocritical care is a multidisciplinary subspecialty that combines expertise in critical care medicine, neurology, and neurosurgery, and has led to improved outcomes in adults who have critical illnesses. Advances in resuscitation and critical care have led to high rates of survival among neonates with life-threatening conditions such as perinatal asphyxia, extreme prematurity, and congenital malformations. The sequelae of neurologic conditions arising in the neonatal period include lifelong disabilities such as cerebral palsy and epilepsy, as well as intellectual and behavioral disabilities. Centers of excellence have adapted the principles of neurocritical care to reflect the needs of the developing newborn brain, including early involvement of a neurologist for recognition and treatment of neurologic conditions, attention to physiology to help prevent secondary brain injury, a protocol-driven approach for common conditions like seizures and hypoxic-ischemic encephalopathy, and education of specialized teams that use brain monitoring and imaging to evaluate the effect of critical illness on brain function and development. Copyright © 2014. Published by Elsevier Inc.

  8. Wireless body sensor networks for health-monitoring applications.

    PubMed

    Hao, Yang; Foster, Robert

    2008-11-01

    Current wireless technologies, such as wireless body area networks and wireless personal area networks, provide promising applications in medical monitoring systems to measure specified physiological data and also provide location-based information, if required. With the increasing sophistication of wearable and implantable medical devices and their integration with wireless sensors, an ever-expanding range of therapeutic and diagnostic applications is being pursued by research and commercial organizations. This paper aims to provide a comprehensive review of recent developments in wireless sensor technology for monitoring behaviour related to human physiological responses. It presents background information on the use of wireless technology and sensors to develop a wireless physiological measurement system. A generic miniature platform and other available technologies for wireless sensors have been studied in terms of hardware and software structural requirements for a low-cost, low-power, non-invasive and unobtrusive system.

  9. A MAC Protocol for Medical Monitoring Applications of Wireless Body Area Networks

    PubMed Central

    Shu, Minglei; Yuan, Dongfeng; Zhang, Chongqing; Wang, Yinglong; Chen, Changfang

    2015-01-01

    Targeting the medical monitoring applications of wireless body area networks (WBANs), a hybrid medium access control protocol using an interrupt mechanism (I-MAC) is proposed to improve the energy and time slot utilization efficiency and to meet the data delivery delay requirement at the same time. Unlike existing hybrid MAC protocols, a superframe structure with a longer length is adopted to avoid unnecessary beacons. The time slots are mostly allocated to nodes with periodic data sources. Short interruption slots are inserted into the superframe to convey the urgent data and to guarantee the real-time requirements of these data. During these interruption slots, the coordinator can break the running superframe and start a new superframe. A contention access period (CAP) is only activated when there are more data that need to be delivered. Experimental results show the effectiveness of the proposed MAC protocol in WBANs with low urgent traffic. PMID:26046596

  10. Network, system, and status software enhancements for the autonomously managed electrical power system breadboard. Volume 2: Protocol specification

    NASA Technical Reports Server (NTRS)

    Mckee, James W.

    1990-01-01

    This volume (2 of 4) contains the specification, structured flow charts, and code listing for the protocol. The purpose of an autonomous power system on a spacecraft is to relieve humans from having to continuously monitor and control the generation, storage, and distribution of power in the craft. This implies that algorithms will have been developed to monitor and control the power system. The power system will contain computers on which the algorithms run. There should be one control computer system that makes the high level decisions and sends commands to and receive data from the other distributed computers. This will require a communications network and an efficient protocol by which the computers will communicate. One of the major requirements on the protocol is that it be real time because of the need to control the power elements.

  11. A low power medium access control protocol for wireless medical sensor networks.

    PubMed

    Lamprinos, I; Prentza, A; Sakka, E; Koutsouris, D

    2004-01-01

    The concept of a wireless integrated network of sensors, already applied in several sectors of our everyday life, such as security, transportation and environment monitoring, can as well provide an advanced monitor and control resource for healthcare services. By networking medical sensors wirelessly, attaching them in patient's body, we create the appropriate infrastructure for continuous and real-time monitoring of patient without discomforting him. This infrastructure can improve healthcare by providing the means for flexible acquisition of vital signs, while at the same time it provides more convenience to the patient. Given the type of wireless network, traditional medium access control (MAC) protocols cannot take advantage of the application specific requirements and information characteristics occurring in medical sensor networks, such as the demand for low power consumption and the rather limited and asymmetric data traffic. In this paper, we present the architecture of a low power MAC protocol, designated to support wireless networks of medical sensors. This protocol aims to improve energy efficiency by exploiting the inherent application features and requirements. It is oriented towards the avoidance of main energy wastage sources, such as idle listening, collision and power outspending.

  12. Evaluation of a new chest tube removal protocol using digital air leak monitoring after lobectomy: a prospective randomised trial.

    PubMed

    Brunelli, Alessandro; Salati, Michele; Refai, Majed; Di Nunzio, Luca; Xiumé, Francesco; Sabbatini, Armando

    2010-01-01

    The objective of this randomised trial was to assess the effectiveness of a new fast-track chest tube removal protocol taking advantage of digital monitoring of air leak compared to a traditional protocol using visual and subjective assessment of air leak (bubbles). One hundred and sixty-six patients submitted to pulmonary lobectomy for lung cancer were randomised in two groups with different chest tube removal protocols: (1) in the new protocol, chest tube was removed based on digitally recorded measurements of air leak flow; (2) in the traditional protocol, the chest tube removal was based on an instantaneous assessment of air leak during daily rounds. The two groups were compared in terms of chest tube duration, hospital stay and costs. The two groups were well matched for several preoperative and operative variables. Compared to the traditional protocol, the new digital recording protocol showed mean reductions in chest tube duration (p=0.0007), hospital stay (p=0.007) of 0.9 day, and a mean cost saving of euro 476 per patient (p=0.008). In the new chest tube removal protocol, 51% of patients had their chest tube removed by the second postoperative day versus only 12% of those in the traditional protocol. The application of a chest tube removal protocol using a digital drainage unit featuring a continuous recording of air leak was safe and cost effective. Although future studies are warranted to confirm these results in other settings, the use of this new protocol is now routinely applied in our practice. Copyright 2009 European Association for Cardio-Thoracic Surgery. Published by Elsevier B.V. All rights reserved.

  13. A New Cellular Architecture for Information Retrieval from Sensor Networks through Embedded Service and Security Protocols

    PubMed Central

    Shahzad, Aamir; Landry, René; Lee, Malrey; Xiong, Naixue; Lee, Jongho; Lee, Changhoon

    2016-01-01

    Substantial changes have occurred in the Information Technology (IT) sectors and with these changes, the demand for remote access to field sensor information has increased. This allows visualization, monitoring, and control through various electronic devices, such as laptops, tablets, i-Pads, PCs, and cellular phones. The smart phone is considered as a more reliable, faster and efficient device to access and monitor industrial systems and their corresponding information interfaces anywhere and anytime. This study describes the deployment of a protocol whereby industrial system information can be securely accessed by cellular phones via a Supervisory Control And Data Acquisition (SCADA) server. To achieve the study goals, proprietary protocol interconnectivity with non-proprietary protocols and the usage of interconnectivity services are considered in detail. They support the visualization of the SCADA system information, and the related operations through smart phones. The intelligent sensors are configured and designated to process real information via cellular phones by employing information exchange services between the proprietary protocol and non-proprietary protocols. SCADA cellular access raises the issue of security flaws. For these challenges, a cryptography-based security method is considered and deployed, and it could be considered as a part of a proprietary protocol. Subsequently, transmission flows from the smart phones through a cellular network. PMID:27314351

  14. A New Cellular Architecture for Information Retrieval from Sensor Networks through Embedded Service and Security Protocols.

    PubMed

    Shahzad, Aamir; Landry, René; Lee, Malrey; Xiong, Naixue; Lee, Jongho; Lee, Changhoon

    2016-06-14

    Substantial changes have occurred in the Information Technology (IT) sectors and with these changes, the demand for remote access to field sensor information has increased. This allows visualization, monitoring, and control through various electronic devices, such as laptops, tablets, i-Pads, PCs, and cellular phones. The smart phone is considered as a more reliable, faster and efficient device to access and monitor industrial systems and their corresponding information interfaces anywhere and anytime. This study describes the deployment of a protocol whereby industrial system information can be securely accessed by cellular phones via a Supervisory Control And Data Acquisition (SCADA) server. To achieve the study goals, proprietary protocol interconnectivity with non-proprietary protocols and the usage of interconnectivity services are considered in detail. They support the visualization of the SCADA system information, and the related operations through smart phones. The intelligent sensors are configured and designated to process real information via cellular phones by employing information exchange services between the proprietary protocol and non-proprietary protocols. SCADA cellular access raises the issue of security flaws. For these challenges, a cryptography-based security method is considered and deployed, and it could be considered as a part of a proprietary protocol. Subsequently, transmission flows from the smart phones through a cellular network.

  15. A comparison of protocols and observer precision for measuring physical stream attributes

    USGS Publications Warehouse

    Whitacre, H.W.; Roper, B.B.; Kershner, J.L.

    2007-01-01

    Stream monitoring programs commonly measure physical attributes to assess the effect of land management on stream habitat. Variability associated with the measurement of these attributes has been linked to a number of factors, but few studies have evaluated variability due to differences in protocols. We compared six protocols, five used by the U.S. Department of Agriculture Forest Service and one by the U.S. Environmental Protection Agency, on six streams in Oregon and Idaho to determine whether differences in protocol affect values for 10 physical stream attributes. Results from Oregon and Idaho were combined for groups participating in both states, with significant differences in attribute means for 9 out of the 10 stream attributes. Significant differences occurred in 5 of 10 in Idaho, and 10 of 10 in Oregon. Coefficients of variation, signal-to-noise ratio, and root mean square error were used to evaluate measurement precision. There were differences among protocols for all attributes when states were analyzed separately and as a combined dataset. Measurement differences were influenced by choice of instruments, measurement method, measurement location, attribute definitions, and training approach. Comparison of data gathered by observers using different protocols will be difficult unless a core set of protocols for commonly measured stream attributes can be standardized among monitoring programs.

  16. Skylab hardware report operational bioinstrumentation system

    NASA Technical Reports Server (NTRS)

    Luczkowski, S.

    1977-01-01

    The Skylab Operational Bioinstrumentation System is a personal, individually adjustable biomedical system designed to monitor the basic physiological functions of each suited crewman during specified periods of a manned space mission. The basic physiological functions of this system include electrocardiogram, respiration by impedance pneumogram, body temperature, cardiotachometer, and subject identification. The Operational Bioinstrumentation System was scheduled to monitor each crewman during launch, extravehicular activities, suited intravehicular experiments, and undocking and return.

  17. Wireless telemedicine systems for diagnosing sleep disorders with Zigbee star network topology

    NASA Astrophysics Data System (ADS)

    Oh, Sechang; Kwon, Hyeokjun; Varadan, Vijay K.

    2012-10-01

    Good sleep is critical for one's overall physical and mental health but more than 50 million Americans have experienced or are suffering from sleep disorders. Nevertheless, 85% of them remain undiagnosed or untreated. They can lead to chronic diseases. Sleep disorders are diagnosed through polysomnography, also known as sleep study, performed in a sleep laboratory overnight. This perturbs his/her daily sleep routine, and consequently, an accurate diagnosis cannot be made. Many companies have been developing home sleep test systems to reduce the cost of sleep studies and provide a more convenience solution to patients. The category of the system varies as type II, type III and type IV according to the type of sleep study. Current systems cannot be easily extended from one type to include a higher type. A patient who has a type III system to diagnose sleep apnea should additionally purchase a type II system which has functions that overlap with a type III system, to evaluate sleep stages. In this paper, we propose a wireless telemedicine system for easy extension of channels using the start network topology of the Zigbee protocol. The HST system consists of two wireless HST devices with a Zigbee module, a wireless HST receiver with both a Zigbee and a Wi-Fi module, and a sever which monitors/saves the physiological signals. One transmitter provides 5 channels for 2x EOG, 2x EEG and EMG to evaluate sleep stages. The other transmitter provides 5 additional channels for ECG, nasal air flow, body position, abdominal/chest efforts and oxygen saturation to diagnose sleep apnea. These two transmitters, acting as routers, and the receiver as a coordinator form a Zigbee star network. The data from each transmitter in the receiver are retransmitted to the monitoring unit through Wi-Fi. By building a star network with Zigbee, channels can be easily extended so that low level systems can be upgraded to higher level systems by simply adding the necessary channels. In addition, the proposed system provides real time monitoring of physiological signals at remote locations using Wi-Fi.

  18. Mobile Monitoring and Embedded Control System for Factory Environment

    PubMed Central

    Lian, Kuang-Yow; Hsiao, Sung-Jung; Sung, Wen-Tsai

    2013-01-01

    This paper proposes a real-time method to carry out the monitoring of factory zone temperatures, humidity and air quality using smart phones. At the same time, the system detects possible flames, and analyzes and monitors electrical load. The monitoring also includes detecting the vibrations of operating machinery in the factory area. The research proposes using ZigBee and Wi-Fi protocol intelligent monitoring system integration within the entire plant framework. The sensors on the factory site deliver messages and real-time sensing data to an integrated embedded systems via the ZigBee protocol. The integrated embedded system is built by the open-source 32-bit ARM (Advanced RISC Machine) core Arduino Due module, where the network control codes are built in for the ARM chipset integrated controller. The intelligent integrated controller is able to instantly provide numerical analysis results according to the received data from the ZigBee sensors. The Android APP and web-based platform are used to show measurement results. The built-up system will transfer these results to a specified cloud device using the TCP/IP protocol. Finally, the Fast Fourier Transform (FFT) approach is used to analyze the power loads in the factory zones. Moreover, Near Field Communication (NFC) technology is used to carry out the actual electricity load experiments using smart phones. PMID:24351642

  19. Mobile monitoring and embedded control system for factory environment.

    PubMed

    Lian, Kuang-Yow; Hsiao, Sung-Jung; Sung, Wen-Tsai

    2013-12-17

    This paper proposes a real-time method to carry out the monitoring of factory zone temperatures, humidity and air quality using smart phones. At the same time, the system detects possible flames, and analyzes and monitors electrical load. The monitoring also includes detecting the vibrations of operating machinery in the factory area. The research proposes using ZigBee and Wi-Fi protocol intelligent monitoring system integration within the entire plant framework. The sensors on the factory site deliver messages and real-time sensing data to an integrated embedded systems via the ZigBee protocol. The integrated embedded system is built by the open-source 32-bit ARM (Advanced RISC Machine) core Arduino Due module, where the network control codes are built in for the ARM chipset integrated controller. The intelligent integrated controller is able to instantly provide numerical analysis results according to the received data from the ZigBee sensors. The Android APP and web-based platform are used to show measurement results. The built-up system will transfer these results to a specified cloud device using the TCP/IP protocol. Finally, the Fast Fourier Transform (FFT) approach is used to analyze the power loads in the factory zones. Moreover, Near Field Communication (NFC) technology is used to carry out the actual electricity load experiments using smart phones.

  20. Signatures of subacute potentially catastrophic illness in the intensive care unit: model development and validation

    PubMed Central

    Moss, Travis J.; Lake, Douglas E.; Forrest Calland, J; Enfield, Kyle B; Delos, John B.; Fairchild, Karen D.; Randall Moorman, J.

    2016-01-01

    Objective Patients in intensive care units are susceptible to subacute, potentially catastrophic illnesses such as respiratory failure, sepsis, and hemorrhage that present as severe derangements of vital signs. More subtle physiologic signatures may be present before clinical deterioration, when treatment might be more effective. We performed multivariate statistical analyses of bedside physiologic monitoring data to identify such early, subclinical signatures of incipient life-threatening illness. Design We report a study of model development and validation of a retrospective observational cohort using resampling (TRIPOD Type 1b internal validation), and a study of model validation using separate data (Type 2b internal/external validation). Setting University of Virginia Health System (Charlottesville), a tertiary-care, academic medical center. Patients Critically ill patients consecutively admitted between January 2009 and June 2015 to either the neonatal, surgical/trauma/burn, or medical intensive care units with available physiologic monitoring data. Interventions None. Measurements and Main Results We analyzed 146 patient-years of vital sign and electrocardiography waveform time series from the bedside monitors of 9,232 ICU admissions. Calculations from 30-minute windows of the physiologic monitoring data were made every 15 minutes. Clinicians identified 1,206 episodes of respiratory failure leading to urgent, unplanned intubation, sepsis, or hemorrhage leading to multi-unit transfusions from systematic, individual chart reviews. Multivariate models to predict events up to 24 hours prior had internally-validated C-statistics of 0.61 to 0.88. In adults, physiologic signatures of respiratory failure and hemorrhage were distinct from each other but externally consistent across ICUs. Sepsis, on the other hand, demonstrated less distinct and inconsistent signatures. Physiologic signatures of all neonatal illnesses were similar. Conclusions Subacute, potentially catastrophic illnesses in 3 diverse ICU populations have physiologic signatures that are detectable in the hours preceding clinical detection and intervention. Detection of such signatures can draw attention to patients at highest risk, potentially enabling earlier intervention and better outcomes. PMID:27452809

  1. Signatures of Subacute Potentially Catastrophic Illness in the ICU: Model Development and Validation.

    PubMed

    Moss, Travis J; Lake, Douglas E; Calland, J Forrest; Enfield, Kyle B; Delos, John B; Fairchild, Karen D; Moorman, J Randall

    2016-09-01

    Patients in ICUs are susceptible to subacute potentially catastrophic illnesses such as respiratory failure, sepsis, and hemorrhage that present as severe derangements of vital signs. More subtle physiologic signatures may be present before clinical deterioration, when treatment might be more effective. We performed multivariate statistical analyses of bedside physiologic monitoring data to identify such early subclinical signatures of incipient life-threatening illness. We report a study of model development and validation of a retrospective observational cohort using resampling (Transparent Reporting of a multivariable prediction model for Individual Prognosis Or Diagnosis type 1b internal validation) and a study of model validation using separate data (type 2b internal/external validation). University of Virginia Health System (Charlottesville), a tertiary-care, academic medical center. Critically ill patients consecutively admitted between January 2009 and June 2015 to either the neonatal, surgical/trauma/burn, or medical ICUs with available physiologic monitoring data. None. We analyzed 146 patient-years of vital sign and electrocardiography waveform time series from the bedside monitors of 9,232 ICU admissions. Calculations from 30-minute windows of the physiologic monitoring data were made every 15 minutes. Clinicians identified 1,206 episodes of respiratory failure leading to urgent unplanned intubation, sepsis, or hemorrhage leading to multi-unit transfusions from systematic individual chart reviews. Multivariate models to predict events up to 24 hours prior had internally validated C-statistics of 0.61-0.88. In adults, physiologic signatures of respiratory failure and hemorrhage were distinct from each other but externally consistent across ICUs. Sepsis, on the other hand, demonstrated less distinct and inconsistent signatures. Physiologic signatures of all neonatal illnesses were similar. Subacute potentially catastrophic illnesses in three diverse ICU populations have physiologic signatures that are detectable in the hours preceding clinical detection and intervention. Detection of such signatures can draw attention to patients at highest risk, potentially enabling earlier intervention and better outcomes.

  2. Informal and formal trail monitoring protocols and baseline conditions: Acadia National Park

    USGS Publications Warehouse

    Marion, Jeffrey L.; Wimpey, Jeremy F.; Park, L.

    2011-01-01

    At Acadia National Park, changing visitor use levels and patterns have contributed to an increasing degree of visitor use impacts to natural and cultural resources. To better understand the extent and severity of these resource impacts and identify effective management techniques, the park sponsored this research to develop monitoring protocols, collect baseline data, and identify suggestions for management strategies. Formal and informal trails were surveyed and their resource conditions were assessed and characterized to support park planning and management decision-making.

  3. The National Riparian Core Protocol: A riparian vegetation monitoring protocol for wadeable streams of the conterminous United States

    Treesearch

    David M. Merritt; Mary E. Manning; Nate Hough-Snee

    2017-01-01

    Riparian areas are hotspots of biological diversity that may serve as high quality habitat for fish and wildlife. The National Riparian Core Protocol (NRCP) provides tools and methods to assist natural resource professionals in sampling riparian vegetation and physical characteristics along wadeable streams. Guidance is provided for collecting basic information on...

  4. Protocols for long-term monitoring of seabird ecology in the Gulf of Alaska

    USGS Publications Warehouse

    Piatt, John F.; Byrd, G. Vernon; Harding, Ann M.A.; Kettle, Arthur B.; Kitaysky, Sasha; Litzow, Michael A.; Roseneau, David G.; Shultz, Michael T.; van Pelt, Thomas I.

    2003-01-01

    Seabird populations will need to be monitored for many years to assess both recovery and ecological conditions affecting recovery. Detailed studies of individual seabird colonies and marine ecosystems in the Gulf of Alaska have been conducted by the U.S. Geological Survey and U.S. Fish and Wildlife Service under the auspices of damage assessment and restoration programs of the Trustee Council. Much has been learned about factors influencing seabird populations and their capacity to recover from the spill in the Gulf of Alaska. As the restoration program moves toward long-term monitoring of populations, however, protocols and long-term monitoring strategies that focus on key parameters of interest and that are inexpensive, practical, and applicable over a large geographic area need to be developed.

  5. Effects of acclimation on poststocking dispersal and physiological condition of age-1 pallid sturgeon

    USGS Publications Warehouse

    Oldenburg, E.W.; Guy, C.S.; Cureton, E.S.; Webb, M.A.H.; Gardner, W.M.

    2011-01-01

    The objective of this study was to evaluate the effects of acclimation to flow and site-specific physicochemical water conditions on poststocking dispersal and physiological condition of age-1 hatchery-reared pallid sturgeon. Fish from three acclimation treatments were radio-tagged, released at two locations (Missouri River and Marias River), and monitored using passive telemetry stations. Marias treatment was acclimated to flow and site-specific physicochemical conditions, Bozeman treatment was acclimated to flow only, and controls had no acclimation (reared under traditional conservation propagation protocol). During both years, fish released in the Missouri River dispersed less than fish released in the Marias River. In 2005, Marias treatment dispersed less and nearly twice as many fish remained in the Missouri River reach as compared to control fish. In 2006, pallid sturgeon dispersed similarly among treatments and the number of fish remaining in the Missouri River reach was similar among all treatments. Differences in poststocking dispersal between years were related to fin curl which was present in all fish in 2005 and only 26% in 2006. Pallid sturgeon from all treatments in both years had a greater affinity for the lower reaches of the Missouri River than the upper reaches. Thus, release site influenced poststocking dispersal more than acclimation treatment. No difference was observed in relative growth rate among treatments. However, acclimation to flow (i.e., exercise conditioning) prevented fat accumulation from rupturing hepatocytes. Acclimation conditions used in this study did not benefit pallid sturgeon unless physiological maladies were present. Overriding all treatment effects was stocking location; thus, natural resource agencies need to consider stocking location carefully to reduce poststocking dispersal. ?? 2011 Blackwell Verlag, Berlin.

  6. The British Services Dhaulagiri Medical Research Expedition 2016: a unique military and civilian research collaboration.

    PubMed

    Mellor, Adrian; Bakker-Dyos, J; Howard, M; Boos, C; Cooke, M; Vincent, E; Scott, P; O'Hara, J; Clarke, S B; Barlow, M; Matu, J; Deighton, K; Hill, N; Newman, C; Cruttenden, R; Holdsworth, D; Woods, D

    2017-12-01

    High-altitude environments lead to a significant physiological challenge and disease processes which can be life threatening; operational effectiveness at high altitude can be severely compromised. The UK military research is investigating ways of mitigating the physiological effects of high altitude. The British Service Dhaulagiri Research Expedition took place from March to May 2016, and the military personnel were invited to consent to a variety of study protocols investigating adaptation to high altitudes and diagnosis of high-altitude illness. The studies took place in remote and austere environments at altitudes of up to 7500 m. This paper gives an overview of the individual research protocols investigated, the execution of the expedition and the challenges involved. 129 servicemen and women were involved at altitudes of up to 7500 m; 8 research protocols were investigated. The outputs from these studies will help to individualise the acclimatisation process and inform strategies for pre-acclimatisation should troops ever need to deploy at high altitude at short notice. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  7. Muscle recruitment variations during wrist flexion exercise: MR evaluation

    NASA Technical Reports Server (NTRS)

    Fleckenstein, J. L.; Watumull, D.; Bertocci, L. A.; Nurenberg, P.; Peshock, R. M.; Payne, J. A.; Haller, R. G.; Blomqvist, C. G. (Principal Investigator)

    1994-01-01

    OBJECTIVE: Many exercise protocols used in physiological studies assume homogeneous and diffuse muscle recruitment. To test this assumption during a "standard" wrist flexion protocol, variations in muscle recruitment were assessed using MRI in eight healthy subjects. MATERIALS AND METHODS: Variations were assessed by comparing the right to the left forearms and the effect of slight (15 degrees) pronation or supination at the wrist. RESULTS: Postexercise imaging showed focal regions of increased signal intensity (SI), indicating relatively strong recruitment, most often in entire muscles, although occasionally only in subvolumes of muscles. In 15 of 26 studies, flexor carpi radialis (FCR) showed more SI than flexor carpi ulnaris, while in 11 studies SI in these muscles increased equivalently. Relatively greater FCR recruitment was seen during pronation and/or use of the nondominant side. Palmaris longus, a wrist flexor, did not appear recruited in 4 of 11 forearms in which it was present. A portion of the superficial finger flexor became hyperintense in 89% of studies, while recruitment of the deep finger flexor was seen only in 43%. CONCLUSION: Inter- and intraindividual variations in forearm muscle recruitment should be anticipated in physiological studies of standard wrist flexion exercise protocols.

  8. A Consensus-Based Interpretation of the Benchmark Evidence from South American Trials: Treatment of Intracranial Pressure Trial.

    PubMed

    Chesnut, Randall M; Bleck, Thomas P; Citerio, Giuseppe; Classen, Jan; Cooper, D James; Coplin, William M; Diringer, Michael N; Grände, Per-Olof; Hemphill, J Claude; Hutchinson, Peter J; Le Roux, Peter; Mayer, Stephan A; Menon, David K; Myburgh, John A; Okonkwo, David O; Robertson, Claudia S; Sahuquillo, Juan; Stocchetti, Nino; Sung, Gene; Temkin, Nancy; Vespa, Paul M; Videtta, Walter; Yonas, Howard

    2015-11-15

    Widely-varying published and presented analyses of the Benchmark Evidence From South American Trials: Treatment of Intracranial Pressure (BEST TRIP) randomized controlled trial of intracranial pressure (ICP) monitoring have suggested denying trial generalizability, questioning the need for ICP monitoring in severe traumatic brain injury (sTBI), re-assessing current clinical approaches to monitored ICP, and initiating a general ICP-monitoring moratorium. In response to this dissonance, 23 clinically-active, international opinion leaders in acute-care sTBI management met to draft a consensus statement to interpret this study. A Delphi method-based approach employed iterative pre-meeting polling to codify the group's general opinions, followed by an in-person meeting wherein individual statements were refined. Statements required an agreement threshold of more than 70% by blinded voting for approval. Seven precisely-worded statements resulted, with agreement levels of 83% to 100%. These statements, which should be read in toto to properly reflect the group's consensus positions, conclude that the BEST TRIP trial: 1) studied protocols, not ICP-monitoring per se; 2) applies only to those protocols and specific study groups and should not be generalized to other treatment approaches or patient groups; 3) strongly calls for further research on ICP interpretation and use; 4) should be applied cautiously to regions with much different treatment milieu; 5) did not investigate the utility of treating monitored ICP in the specific patient group with established intracranial hypertension; 6) should not change the practice of those currently monitoring ICP; and 7) provided a protocol, used in non-monitored study patients, that should be considered when treating without ICP monitoring. Consideration of these statements can clarify study interpretation.

  9. The Robinson Protocol: a treadmill anaerobic performance test.

    PubMed

    Robinson, Ellyn M; Graham, Louise B; Headley, Samuel A

    2004-08-01

    The current investigation was designed to further examine the reliability of the Robinson protocol, which is a run-to-exhaustion treadmill test. Robinson (10) originally examined this protocol with 5 subjects. The significance of the initial exploratory study was the impetus for expanding the study to examine the reliability of the protocol with a larger sample. Fifteen male subjects participated in 3 trial runs on the treadmill. The first trial was a modified McConnell (7) test to determine the aerobic capacity of each subject. The second and third trials were identical Robinson protocols (10). The first trial run mean, in seconds (262.04 +/- 74.50), was not significantly different from the second trial run mean (257.30 +/- 72.65), p = 0.526 (2 tailed). As expected, trial 1 and trial 2 were highly correlated (intraclass) (r = 0.927, p < 0.001). These results provide additional support for the hypothesis that the Robinson protocol with a greater subject pool is a reliable protocol that can be used in research studies interested in examining various physiological interventions or anaerobic training.

  10. COMPARISON OF USEPA FIELD SAMPLING METHODS FOR BENTHIC MACROINVERTEBRATE STUDIES

    EPA Science Inventory

    Two U.S. Environmental Protection Agency (USEPA) macroinvertebrate sampling protocols were compared in the Mid-Atlantic Highlands region. The Environmental Monitoring and Assessment Program (EMAP) wadeable streams protocol results in a single composite sample from nine transects...

  11. A knowledge authoring tool for clinical decision support.

    PubMed

    Dunsmuir, Dustin; Daniels, Jeremy; Brouse, Christopher; Ford, Simon; Ansermino, J Mark

    2008-06-01

    Anesthesiologists in the operating room are unable to constantly monitor all data generated by physiological monitors. They are further distracted by clinical and educational tasks. An expert system would ideally provide assistance to the anesthesiologist in this data-rich environment. Clinical monitoring expert systems have not been widely adopted, as traditional methods of knowledge encoding require both expert medical and programming skills, making knowledge acquisition difficult. A software application was developed for use as a knowledge authoring tool for physiological monitoring. This application enables clinicians to create knowledge rules without the need of a knowledge engineer or programmer. These rules are designed to provide clinical diagnosis, explanations and treatment advice for optimal patient care to the clinician in real time. By intelligently combining data from physiological monitors and demographical data sources the expert system can use these rules to assist in monitoring the patient. The knowledge authoring process is simplified by limiting connective relationships between rules. The application is designed to allow open collaboration between communities of clinicians to build a library of rules for clinical use. This design provides clinicians with a system for parameter surveillance and expert advice with a transparent pathway of reasoning. A usability evaluation demonstrated that anesthesiologists can rapidly develop useful rules for use in a predefined clinical scenario.

  12. Medical smart textiles based on fiber optic technology: an overview.

    PubMed

    Massaroni, Carlo; Saccomandi, Paola; Schena, Emiliano

    2015-04-13

    The growing interest in the development of smart textiles for medical applications is driven by the aim to increase the mobility of patients who need a continuous monitoring of such physiological parameters. At the same time, the use of fiber optic sensors (FOSs) is gaining large acceptance as an alternative to traditional electrical and mechanical sensors for the monitoring of thermal and mechanical parameters. The potential impact of FOSs is related to their good metrological properties, their small size and their flexibility, as well as to their immunity from electromagnetic field. Their main advantage is the possibility to use textile based on fiber optic in a magnetic resonance imaging environment, where standard electronic sensors cannot be employed. This last feature makes FOSs suitable for monitoring biological parameters (e.g., respiratory and heartbeat monitoring) during magnetic resonance procedures. Research interest in combining FOSs and textiles into a single structure to develop wearable sensors is rapidly growing. In this review we provide an overview of the state-of-the-art of textiles, which use FOSs for monitoring of mechanical parameters of physiological interest. In particular we briefly describe the working principle of FOSs employed in this field and their relevant advantages and disadvantages. Also reviewed are their applications for the monitoring of mechanical parameters of physiological interest.

  13. Medical Smart Textiles Based on Fiber Optic Technology: An Overview

    PubMed Central

    Massaroni, Carlo; Saccomandi, Paola; Schena, Emiliano

    2015-01-01

    The growing interest in the development of smart textiles for medical applications is driven by the aim to increase the mobility of patients who need a continuous monitoring of such physiological parameters. At the same time, the use of fiber optic sensors (FOSs) is gaining large acceptance as an alternative to traditional electrical and mechanical sensors for the monitoring of thermal and mechanical parameters. The potential impact of FOSs is related to their good metrological properties, their small size and their flexibility, as well as to their immunity from electromagnetic field. Their main advantage is the possibility to use textile based on fiber optic in a magnetic resonance imaging environment, where standard electronic sensors cannot be employed. This last feature makes FOSs suitable for monitoring biological parameters (e.g., respiratory and heartbeat monitoring) during magnetic resonance procedures. Research interest in combining FOSs and textiles into a single structure to develop wearable sensors is rapidly growing. In this review we provide an overview of the state-of-the-art of textiles, which use FOSs for monitoring of mechanical parameters of physiological interest. In particular we briefly describe the working principle of FOSs employed in this field and their relevant advantages and disadvantages. Also reviewed are their applications for the monitoring of mechanical parameters of physiological interest. PMID:25871010

  14. Perceptions of seniors with heart failure regarding autonomous zero-effort monitoring of physiological parameters in the smart-home environment.

    PubMed

    Grace, Sherry L; Taherzadeh, Golnoush; Jae Chang, Isaac Sung; Boger, Jennifer; Arcelus, Amaya; Mak, Susanna; Chessex, Caroline; Mihailidis, Alex

    Technological advances are leading to the ability to autonomously monitor patient's health status in their own homes, to enable aging-in-place. To understand the perceptions of seniors with heart failure (HF) regarding smart-home systems to monitor their physiological parameters. In this qualitative study, HF outpatients were invited to a smart-home lab, where they completed a sequence of activities, during which the capacity of 5 autonomous sensing modalities was compared to gold standard measures. Afterwards, a semi-structured interview was undertaken. These were transcribed and analyzed using an interpretive-descriptive approach. Five themes emerged from the 26 interviews: (1) perceptions of technology, (2) perceived benefits of autonomous health monitoring, (3) disadvantages of autonomous monitoring, (4) lack of perceived need for continuous health monitoring, and (5) preferences for autonomous monitoring. Patient perception towards autonomous monitoring devices was positive, lending credence to zero-effort technology as a viable and promising approach. Copyright © 2017 Elsevier Inc. All rights reserved.

  15. Acute Physiological Responses to Strongman Training Compared to Traditional Strength Training.

    PubMed

    Harris, Nigel K; Woulfe, Colm J; Wood, Matthew R; Dulson, Deborah K; Gluchowski, Ashley K; Keogh, Justin B

    2016-05-01

    Strongman training (ST) has become an increasingly popular modality, but data on physiological responses are limited. This study sought to determine physiological responses to an ST session compared to a traditional strength exercise training (RST) session. Ten healthy men (23.6 ± 27.5 years, 85.8 ± 10.3 kg) volunteered in a crossover design, where all participants performed an ST session, an RST session, and a resting session within 7 days apart. The ST consisted of sled drag, farmer's walk, 1 arm dumbbell clean and press, and tire flip at loads eliciting approximately 30 seconds of near maximal effort per set. The RST consisted of squat, deadlift, bench press, and power clean, progressing to 75% of 1 repetition maximum. Sessions were equated for approximate total set duration. Blood lactate and salivary testosterone were recorded immediately before and after training sessions. Heart rate, caloric expenditure, and substrate utilization were measured throughout the resting session, both training protocols and for 80 minutes after training sessions. Analyses were conducted to determine differences in physiological responses within and between protocols. No significant changes in testosterone occurred at any time point for either session. Lactate increased significantly immediately after both sessions. Heart rate, caloric expenditure, and substrate utilization were all elevated significantly during ST and RST. Heart rate and fat expenditure were significantly elevated compared to resting in both sessions' recovery periods; calorie and carbohydrate expenditures were not. Compared to RST, ST represents an equivalent physiological stimulus on key parameters indicative of potential training-induced adaptive responses. Such adaptations could conceivably include cardiovascular conditioning.

  16. Autonomic physiological data associated with simulator discomfort

    NASA Technical Reports Server (NTRS)

    Miller, James C.; Sharkey, Thomas J.; Graham, Glenna A.; Mccauley, Michael E.

    1993-01-01

    The development of a physiological monitoring capability for the Army's advanced helicopter simulator facility is reported. Additionally, preliminary physiological data is presented. Our objective was to demonstrate the sensitivity of physiological measures in this simulator to self-reported simulator sickness. The data suggested that heart period, hypergastria, and skin conductance level were more sensitive to simulator sickness than were vagal tone and normal electrogastric activity.

  17. Flight physiology training experiences and perspectives: survey of 117 pilots.

    PubMed

    Patrão, Luís; Zorro, Sara; Silva, Jorge; Castelo-Branco, Miguel; Ribeiro, João

    2013-06-01

    Human factors and awareness of flight physiology play a crucial role in flight safety. Even so, international legislation is vague relative to training requirements in hypoxia and altitude physiology. Based on a previously developed survey, an adapted questionnaire was formulated and released online for Portuguese pilots. Specific questions regarding the need for pilot attention monitoring systems were added to the original survey. There were 117 pilots, 2 of whom were women, who completed the survey. Most of the pilots had a light aviation license and flew in unpressurized cabins at a maximum ceiling of 10,000 ft (3048 m). The majority of the respondents never experienced hypoxic symptoms. In general, most of the individuals agreed with the importance of an introductory hypoxia course without altitude chamber training (ACT) for all pilot populations, and with a pilot monitoring system in order to increase flight safety. Generally, most of the pilots felt that hypoxia education and training for unpressurized aircraft is not extensive enough. However, almost all the respondents were willing to use a flight physiology monitoring system in order to improve flight safety.

  18. Monitoring of patients treated with lithium for bipolar disorder: an international survey.

    PubMed

    Nederlof, M; Heerdink, E R; Egberts, A C G; Wilting, I; Stoker, L J; Hoekstra, R; Kupka, R W

    2018-04-14

    Adequate monitoring of patients using lithium is needed for optimal dosing and for early identification of patients with (potential) ADEs. The objective was to internationally assess how health care professionals monitor patients treated with lithium for bipolar disorder. Using networks of various professional organizations, an anonymous online survey was conducted among health care professionals prescribing lithium. Target lithium serum levels and frequency of monitoring was assessed together with monitoring of physical and laboratory parameters. Reasons to and not to monitor and use of guidelines and institutional protocols, and local monitoring systems were investigated. The survey was completed by 117 health care professionals incorporating responses from twenty-four countries. All prescribers reported to monitor lithium serum levels on a regular basis, with varying target ranges. Almost all (> 97%) monitored thyroid and renal function before start and during maintenance treatment. Reported monitoring of other laboratory and physical parameters was variable. The majority of respondents (74%) used guidelines or institutional protocols for monitoring. In general, the prescriber was responsible for monitoring, had to request every monitoring parameter separately and only a minority of patients was automatically invited. Lithium serum levels, renal and thyroid function were monitored by (almost) all physicians. However, there was considerable variation in other monitoring parameters. Our results help to understand why prescribers of lithium monitor patients and what their main reasons are not to monitor patients using lithium.

  19. Intrinsic optical signal imaging of glucose-stimulated physiological responses in the insulin secreting INS-1 β-cell line

    NASA Astrophysics Data System (ADS)

    Li, Yi-Chao; Cui, Wan-Xing; Wang, Xu-Jing; Amthor, Franklin; Yao, Xin-Cheng

    2011-03-01

    Intrinsic optical signal (IOS) imaging has been established for noninvasive monitoring of stimulus-evoked physiological responses in the retina and other neural tissues. Recently, we extended the IOS imaging technology for functional evaluation of insulin secreting INS-1 cells. INS-1 cells provide a popular model for investigating β-cell dysfunction and diabetes. Our experiments indicate that IOS imaging allows simultaneous monitoring of glucose-stimulated physiological responses in multiple cells with high spatial (sub-cellular) and temporal (sub-second) resolution. Rapid image sequences reveal transient optical responses that have time courses comparable to glucose-evoked β-cell electrical activities.

  20. Cerebrospinal fluid volume measurements in hydrocephalic rats.

    PubMed

    Basati, Sukhraaj; Desai, Bhargav; Alaraj, Ali; Charbel, Fady; Linninger, Andreas

    2012-10-01

    Object Experimental data about the evolution of intracranial volume and pressure in cases of hydrocephalus are limited due to the lack of available monitoring techniques. In this study, the authors validate intracranial CSF volume measurements within the lateral ventricle, while simultaneously using impedance sensors and pressure transducers in hydrocephalic animals. Methods A volume sensor was fabricated and connected to a catheter that was used as a shunt to withdraw CSF. In vitro bench-top calibration experiments were created to provide data for the animal experiments and to validate the sensors. To validate the measurement technique in a physiological system, hydrocephalus was induced in weanling rats by kaolin injection into the cisterna magna. At 28 days after induction, the sensor was implanted into the lateral ventricles. After sealing the skull using dental cement, an acute CSF drainage/infusion protocol consisting of 4 sequential phases was performed with a pump. Implant location was confirmed via radiography using intraventricular iohexol contrast administration. Results Controlled CSF shunting in vivo with hydrocephalic rats resulted in precise and accurate sensor measurements (r = 0.98). Shunting resulted in a 17.3% maximum measurement error between measured volume and actual volume as assessed by a Bland-Altman plot. A secondary outcome confirmed that both ventricular volume and intracranial pressure decreased during CSF shunting and increased during infusion. Ventricular enlargement consistent with successful hydrocephalus induction was confirmed using imaging, as well as postmortem. These results indicate that volume monitoring is feasible for clinical cases of hydrocephalus. Conclusions This work marks a departure from traditional shunting systems currently used to treat hydrocephalus. The overall clinical application is to provide alternative monitoring and treatment options for patients. Future work includes development and testing of a chronic (long-term) volume monitoring system.

  1. Biomechanical regulation of in vitro cardiogenesis for tissue-engineered heart repair.

    PubMed

    Zimmermann, Wolfram-Hubertus

    2013-01-01

    The heart is a continuously pumping organ with an average lifespan of eight decades. It develops from the onset of embryonic cardiogenesis under biomechanical load, performs optimally within a defined range of hemodynamic load, and fails if acutely or chronically overloaded. Unloading of the heart leads to defective cardiogenesis in utero, but can also lead to a desired therapeutic outcome (for example, in patients with heart failure under left ventricular assist device therapy). In light of the well-documented relevance of mechanical loading for cardiac physiology and pathology, it is plausible that tissue engineers have integrated mechanical stimulation regimens into protocols for heart muscle construction. To achieve optimal results, physiological principles of beat-to-beat myocardial loading and unloading should be simulated. In addition, heart muscle engineering, in particular if based on pluripotent stem cell-derived cardiomyocytes, may benefit from staggered tonic loading protocols to simulate viscoelastic properties of the prenatal and postnatal myocardial stroma. This review will provide an overview of heart muscle mechanics, summarize observations on the role of mechanical loading for heart development and postnatal performance, and discuss how physiological loading regimens can be exploited to advance myocardial tissue engineering towards a therapeutic application.

  2. Biomechanical regulation of in vitro cardiogenesis for tissue-engineered heart repair

    PubMed Central

    2013-01-01

    The heart is a continuously pumping organ with an average lifespan of eight decades. It develops from the onset of embryonic cardiogenesis under biomechanical load, performs optimally within a defined range of hemodynamic load, and fails if acutely or chronically overloaded. Unloading of the heart leads to defective cardiogenesis in utero, but can also lead to a desired therapeutic outcome (for example, in patients with heart failure under left ventricular assist device therapy). In light of the well-documented relevance of mechanical loading for cardiac physiology and pathology, it is plausible that tissue engineers have integrated mechanical stimulation regimens into protocols for heart muscle construction. To achieve optimal results, physiological principles of beat-to-beat myocardial loading and unloading should be simulated. In addition, heart muscle engineering, in particular if based on pluripotent stem cell-derived cardiomyocytes, may benefit from staggered tonic loading protocols to simulate viscoelastic properties of the prenatal and postnatal myocardial stroma. This review will provide an overview of heart muscle mechanics, summarize observations on the role of mechanical loading for heart development and postnatal performance, and discuss how physiological loading regimens can be exploited to advance myocardial tissue engineering towards a therapeutic application. PMID:24229468

  3. Investigating the application of motion accelerometers as a sleep monitoring technique and the clinical burden of the intensive care environment on sleep quality: study protocol for a prospective observational study in Australia

    PubMed Central

    Currie, Marian J; Huang, Hsin-Chia Carol; Litton, Edward; Wibrow, Bradley; Lopez, Violeta; Haren, Frank Van

    2018-01-01

    Introduction Sleep is a state of quiescence that facilitates the significant restorative processes that enhance individuals’ physiological and psychological well-being. Patients admitted to the intensive care unit (ICU) experience substantial sleep disturbance. Despite the biological importance of sleep, sleep monitoring does not form part of standard clinical care for critically ill patients. There exists an unmet need to assess the feasibility and accuracy of a range of sleep assessment techniques that have the potential to allow widespread implementation of sleep monitoring in the ICU. Key measures The coprimary outcome measures of this study are to: determine the accuracy and feasibility of motion accelerometer monitoring (ie, actigraphy) and subjective assessments of sleep (nursing-based observations and patient self-reports) to the gold standard of sleep monitoring (ie, polysomnography) in evaluating sleep continuity and disturbance. The secondary outcome measures of the study will include: (1) the association between sleep disturbance and environmental factors (eg, noise, light and clinical interactions) and (2) to describe the sleep architecture of intensive care patients. Methods and analysis A prospective, single centre observational design with a within subjects’ assessment of sleep monitoring techniques. The sample will comprise 80 adults (aged 18 years or more) inclusive of ventilated and non-ventilated patients, admitted to a tertiary ICU with a Richmond Agitation-Sedation Scale score between +2 (agitated) and −3 (moderate sedation) and an anticipated length of stay >24 hours. Patients’ sleep quality, total sleep time and sleep fragmentations will be continuously monitored for 24 hours using polysomnography and actigraphy. Behavioural assessments (nursing observations) and patients’ self-reports of sleep quality will be assessed during the 24-hour period using the Richards-Campbell Sleep Questionnaire, subjective sleepiness evaluated via the Karolinska Sleepiness Scale, along with a prehospital discharge survey regarding patients’ perception of sleep quality and disturbing factors using the Little Sleep Questionnaire will be undertaken. Associations between sleep disturbance, noise and light levels, and the frequency of clinical interactions will also be investigated. Sound and luminance levels will be recorded at 1 s epochs via Extech SDL600 and SDL400 monitoring devices. Clinical interactions will be logged via the electronic patient record system Metavision which documents patient monitoring and clinical care. Ethics and dissemination The relevant institutions have approved the study protocol and consent procedures. The findings of the study will contribute to the understanding of sleep disturbance, and the ability to implement sleep monitoring methods within ICUs. Understanding the contribution of a clinical environment on sleep disturbance may provide insight into the need to address clinical environmental issues that may positively influence patient outcomes, and could dispel notions that the environment is a primary factor in sleep disturbance. The research findings will be disseminated via presentations at national and international conferences, proceedings and published articles in peer-reviewed journals. Trial registration number ACTRN12615000945527; Pre-results. PMID:29358448

  4. Investigating the application of motion accelerometers as a sleep monitoring technique and the clinical burden of the intensive care environment on sleep quality: study protocol for a prospective observational study in Australia.

    PubMed

    Delaney, Lori J; Currie, Marian J; Huang, Hsin-Chia Carol; Litton, Edward; Wibrow, Bradley; Lopez, Violeta; Haren, Frank Van

    2018-01-21

    Sleep is a state of quiescence that facilitates the significant restorative processes that enhance individuals' physiological and psychological well-being. Patients admitted to the intensive care unit (ICU) experience substantial sleep disturbance. Despite the biological importance of sleep, sleep monitoring does not form part of standard clinical care for critically ill patients. There exists an unmet need to assess the feasibility and accuracy of a range of sleep assessment techniques that have the potential to allow widespread implementation of sleep monitoring in the ICU. The coprimary outcome measures of this study are to: determine the accuracy and feasibility of motion accelerometer monitoring (ie, actigraphy) and subjective assessments of sleep (nursing-based observations and patient self-reports) to the gold standard of sleep monitoring (ie, polysomnography) in evaluating sleep continuity and disturbance. The secondary outcome measures of the study will include: (1) the association between sleep disturbance and environmental factors (eg, noise, light and clinical interactions) and (2) to describe the sleep architecture of intensive care patients. A prospective, single centre observational design with a within subjects' assessment of sleep monitoring techniques. The sample will comprise 80 adults (aged 18 years or more) inclusive of ventilated and non-ventilated patients, admitted to a tertiary ICU with a Richmond Agitation-Sedation Scale score between +2 (agitated) and -3 (moderate sedation) and an anticipated length of stay >24 hours. Patients' sleep quality, total sleep time and sleep fragmentations will be continuously monitored for 24 hours using polysomnography and actigraphy. Behavioural assessments (nursing observations) and patients' self-reports of sleep quality will be assessed during the 24-hour period using the Richards-Campbell Sleep Questionnaire, subjective sleepiness evaluated via the Karolinska Sleepiness Scale, along with a prehospital discharge survey regarding patients' perception of sleep quality and disturbing factors using the Little Sleep Questionnaire will be undertaken. Associations between sleep disturbance, noise and light levels, and the frequency of clinical interactions will also be investigated. Sound and luminance levels will be recorded at 1 s epochs via Extech SDL600 and SDL400 monitoring devices. Clinical interactions will be logged via the electronic patient record system Metavision which documents patient monitoring and clinical care. The relevant institutions have approved the study protocol and consent procedures. The findings of the study will contribute to the understanding of sleep disturbance, and the ability to implement sleep monitoring methods within ICUs. Understanding the contribution of a clinical environment on sleep disturbance may provide insight into the need to address clinical environmental issues that may positively influence patient outcomes, and could dispel notions that the environment is a primary factor in sleep disturbance. The research findings will be disseminated via presentations at national and international conferences, proceedings and published articles in peer-reviewed journals. ACTRN12615000945527; Pre-results. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  5. Neuromuscular Fatigue and Physiological Responses After Five Dynamic Squat Exercise Protocols.

    PubMed

    Raeder, Christian; Wiewelhove, Thimo; Westphal-Martinez, Marc P; Fernandez-Fernandez, Jaime; de Paula Simola, Rauno A; Kellmann, Michael; Meyer, Tim; Pfeiffer, Mark; Ferrauti, Alexander

    2016-04-01

    This aimed to analyze neuromuscular, physiological and perceptual responses to a single bout of 5 different dynamic squat exercise protocols. In a randomized and counterbalanced order, 15 male resistance-trained athletes (mean ± SD; age: 23.1 ± 1.9 years, body mass: 77.4 ± 8.0 kg) completed traditional multiple sets (MS: 4 × 6, 85% 1 repetition maximum [RM]), drop sets (DS: 1 × 6, 85% 1RM + 3 drop sets), eccentric overload (EO: 4 × 6, 70% 1RM concentric, 100% 1RM eccentric), flywheel YoYo squat (FW: 4 × 6, all-out), and a plyometric jump protocol (PJ: 4 × 15, all-out). Blood lactate (La), ratings of perceived exertion (RPE), counter movement jump height (CMJ), multiple rebound jump (MRJ) performance, maximal voluntary isometric contraction force, serum creatine kinase (CK) and delayed onset muscle soreness were measured. Immediately post exercise, La was significantly (p < 0.001) higher in FW (mean ± 95% confidence limit; 12.2 ± 0.9 mmol·L) and lower in PJ (3.0 ± 0.8 mmol·L) compared with MS (7.7 ± 1.5 mmol·L), DS (8.5 ± 0.6 mmol·L), and EO (8.2 ± 1.6 mmol·L), accompanied by similar RPE responses. Neuromuscular performance (CMJ, MRJ) significantly remained decreased (p < 0.001) from 0.5 to 48 hours post exercise in all protocols. There was a significant time × protocol interaction (p ≤ 0.05) in MRJ with a significant lower performance in DS, EO, and FW compared with PJ (0.5 hours post exercise), and in EO compared with all other protocols (24 hours post exercise). A significant main time effect with peak values 24 hours post exercise was observed in CK serum concentrations (p < 0.001), but there was no time × protocol interaction. In conclusion, (a) metabolic and perceptual demands were higher in FW and EO compared with MS, DS and PJ, (b) neuromuscular fatigue was consistent up to 48 hours post exercise in all protocols, and (c) EO induced the greatest neuromuscular fatigue.

  6. How often are thoughts metacognitive? Findings from research on self-regulated learning, think-aloud protocols, and mind-wandering.

    PubMed

    Jordano, Megan L; Touron, Dayna R

    2018-05-31

    Metacognitive monitoring refers to how people evaluate their cognitive performance. An extensive literature examines how accurately individuals engage in monitoring. The question of how often individuals engage in metacognitive monitoring has been largely neglected, although one might expect situational, group, and individual variability in monitoring frequency. We argue that this is a critical omission, given that the frequency of metacognitive monitoring might have important implications for monitoring accuracy and task performance. Within this review, we highlight findings from three literatures, that each provide insight into how often individuals engage in monitoring. To clarify the important links and potential overlaps between these separate bodies of research, we begin by summarizing the metacognitive monitoring literature, including age-related patterns in monitoring accuracy. We then connect these questions regarding spontaneous monitoring, including age-related patterns in spontaneous monitoring, to targeted reviews of the self-regulated learning, think-aloud protocol, and mind-wandering literatures. We discuss situational and dispositional factors believed to influence monitoring accuracy, and propose that the same factors could potentially influence the frequency of spontaneous monitoring. Additionally, we propose that age-related increases in spontaneous monitoring (as suggested by age-related increases in TRI) may contribute to older adults' intact monitoring abilities. It is our hope that this review will encourage increased attention and research on the topic of spontaneous monitoring.

  7. Protocol for monitoring metals in Ozark National Scenic Riverways, Missouri: Version 1.0

    USGS Publications Warehouse

    Schmitt, Christopher J.; Brumbaugh, William G.; Besser, John M.; Hinck, Jo Ellen; Bowles, David E.; Morrison, Lloyd W.; Williams, Michael H.

    2008-01-01

    The National Park Service is developing a monitoring plan for the Ozark National Scenic Riverways in southeastern Missouri. Because of concerns about the release of lead, zinc, and other metals from lead-zinc mining to streams, the monitoring plan will include mining-related metals. After considering a variety of alternatives, the plan will consist of measuring the concentrations of cadmium, cobalt, lead, nickel, and zinc in composite samples of crayfish (Orconectes luteus or alternate species) and Asian clam (Corbicula fluminea) collected periodically from selected sites. This document, which comprises a protocol narrative and supporting standard operating procedures, describes the methods to be employed prior to, during, and after collection of the organisms, along with procedures for their chemical analysis and quality assurance; statistical analysis, interpretation, and reporting of the data; and for modifying the protocol narrative and supporting standard operating procedures. A list of supplies and equipment, data forms, and sample labels are also included. An example based on data from a pilot study is presented.

  8. Early Ambulation After Microsurgical Reconstruction of the Lower Extremity.

    PubMed

    Orseck, Michael J; Smith, Christopher Robert; Kirby, Sean; Trujillo, Manuel

    2018-06-01

    Successful outcomes after microsurgical reconstruction of the lower extremity include timely return to ambulation. Some combination of physical examination, ViOptix tissue oxygen saturation monitoring, and the implantable venous Doppler have shown promise in increasing sensitivity of current flap monitoring. We have incorporated this system into our postoperative monitoring protocol in an effort to initiate earlier dependency protocols. A prospective analysis of 36 anterolateral thigh free flap and radial forearm flaps for lower extremity reconstruction was performed. Indications for reconstruction were acute and chronic wounds, as well as oncologic resection. Twenty-three patients were able to ambulate and 3 were able to dangle their leg on the first postoperative day. One flap showed early mottling that improved immediately after elevation. After reelevation and return to baseline, the dependency protocol was successfully implemented on postoperative day 3. All flaps went on to successful healing. Physical examination, implantable venous Doppler, and ViOptix can be used reliably as an adjunct to increase the sensitivity of detecting poorly performing flaps during the postoperative progression of dependency.

  9. Design, rationale and feasibility of a multidimensional experimental protocol to study early life stress.

    PubMed

    Bartholomeusz, M Dillwyn; Bolton, Philip S; Callister, Robin; Skinner, Virginia; Hodgson, Deborah

    2017-09-01

    There is a rapidly accumulating body of evidence regarding the influential role of early life stress (ELS) upon medical and psychiatric conditions. While self-report instruments, with their intrinsic limitations of recall, remain the primary means of detecting ELS in humans, biological measures are generally limited to a single biological system. This paper describes the design, rationale and feasibility of a study to simultaneously measure neuroendocrine, immune and autonomic nervous system (ANS) responses to psychological and physiological stressors in relation to ELS. Five healthy university students were recruited by advertisement. Exclusion criteria included chronic medical conditions, psychotic disorders, needle phobia, inability to tolerate pain, and those using anti-inflammatory medications. They were clinically interviewed and physiological recordings made over a two-hour period pre, during and post two acute stressors: the cold pressor test and recalling a distressing memory. The Childhood Trauma Questionnaire and the Parental Bonding Index were utilised to measure ELS. Other psychological measures of mood and personality were also administered. Measurements of heart rate, blood pressure, respiratory rate, skin conductance, skin blood flow and temporal plasma samples were successfully obtained before, during and after acute stress. Participants reported the extensive psychological and multisystem physiological data collection and stress provocations were tolerable. Most (4/5) participants indicated a willingness to return to repeat the protocol, indicating acceptability. Our protocol is viable and safe in young physically healthy adults and allows us to assess simultaneously neuroendocrine, immune and autonomic nervous system responses to stressors in persons assessed for ELS.

  10. Living high training low induces physiological cardiac hypertrophy accompanied by down-regulation and redistribution of the renin-angiotensin system

    PubMed Central

    Shi, Wei; Meszaros, J Gary; Zeng, Shao-ju; Sun, Ying-yu; Zuo, Ming-xue

    2013-01-01

    Aim: Living high training low” (LHTL) is an exercise-training protocol that refers living in hypoxia stress and training at normal level of O2. In this study, we investigated whether LHTL caused physiological heart hypertrophy accompanied by changes of biomarkers in renin-angiotensin system in rats. Methods: Adult male SD rats were randomly assigned into 4 groups, and trained on living low-sedentary (LLS, control), living low-training low (LLTL), living high-sedentary (LHS) and living high-training low (LHTL) protocols, respectively, for 4 weeks. Hematological parameters, hemodynamic measurement, heart hypertrophy and plasma angiotensin II (Ang II) level of the rats were measured. The gene and protein expression of angiotensin-converting enzyme (ACE), angiotensinogen (AGT) and angiotensin II receptor I (AT1) in heart tissue was assessed using RT-PCR and immunohistochemistry, respectively. Results: LLTL, LHS and LHTL significantly improved cardiac function, increased hemoglobin concentration and RBC. At the molecular level, LLTL, LHS and LHTL significantly decreased the expression of ACE, AGT and AT1 genes, but increased the expression of ACE and AT1 proteins in heart tissue. Moreover, ACE and AT1 protein expression was significantly increased in the endocardium, but unchanged in the epicardium. Conclusion: LHTL training protocol suppresses ACE, AGT and AT1 gene expression in heart tissue, but increases ACE and AT1 protein expression specifically in the endocardium, suggesting that the physiological heart hypertrophy induced by LHTL is regulated by region-specific expression of renin-angiotensin system components. PMID:23377552

  11. [A security protocol for the exchange of personal medical data via Internet: monitoring treatment and drug effects].

    PubMed

    Viviani, R; Fischer, J; Spitzer, M; Freudenmann, R W

    2004-04-01

    We present a security protocol for the exchange of medical data via the Internet, based on the type/domain model. We discuss two applications of the protocol: in a system for the exchange of data for quality assurance, and in an on-line database of adverse reactions to drug use. We state that a type/domain security protocol can successfully comply with the complex requirements for data privacy and accessibility typical of such applications.

  12. Non-Intrusive Load Monitoring Assessment: Literature Review and Laboratory Protocol

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Butner, R. Scott; Reid, Douglas J.; Hoffman, Michael G.

    2013-07-01

    To evaluate the accuracy of NILM technologies, a literature review was conducted to identify any test protocols or standardized testing approaches currently in use. The literature review indicated that no consistent conventions were currently in place for measuring the accuracy of these technologies. Consequently, PNNL developed a testing protocol and metrics to provide the basis for quantifying and analyzing the accuracy of commercially available NILM technologies. This report discusses the results of the literature review and the proposed test protocol and metrics in more detail.

  13. Form Factor Evaluation of Open Body Area Network (OBAN) Physiological Status Monitoring (PSM) System Prototype Designs

    DTIC Science & Technology

    2018-05-11

    SYSTEM PROTOTYPE DESIGNS DISCLAIMERS The opinions or assertions contained herein are the private views of the author(s) and are not to be construed as...FORM FACTOR EVALUATION OF OPEN BODY AREA NETWORK (OBAN) PHYSIOLOGICAL STATUS MONITORING (PSM) SYSTEM PROTOTYPE DESIGNS William J...security; and is designed to function for 72 hours or more. The test described in this report assesses proposed form-factor designs . Feedback using

  14. Bioresorbable silicon electronics for transient spatiotemporal mapping of electrical activity from the cerebral cortex.

    PubMed

    Yu, Ki Jun; Kuzum, Duygu; Hwang, Suk-Won; Kim, Bong Hoon; Juul, Halvor; Kim, Nam Heon; Won, Sang Min; Chiang, Ken; Trumpis, Michael; Richardson, Andrew G; Cheng, Huanyu; Fang, Hui; Thomson, Marissa; Bink, Hank; Talos, Delia; Seo, Kyung Jin; Lee, Hee Nam; Kang, Seung-Kyun; Kim, Jae-Hwan; Lee, Jung Yup; Huang, Younggang; Jensen, Frances E; Dichter, Marc A; Lucas, Timothy H; Viventi, Jonathan; Litt, Brian; Rogers, John A

    2016-07-01

    Bioresorbable silicon electronics technology offers unprecedented opportunities to deploy advanced implantable monitoring systems that eliminate risks, cost and discomfort associated with surgical extraction. Applications include postoperative monitoring and transient physiologic recording after percutaneous or minimally invasive placement of vascular, cardiac, orthopaedic, neural or other devices. We present an embodiment of these materials in both passive and actively addressed arrays of bioresorbable silicon electrodes with multiplexing capabilities, which record in vivo electrophysiological signals from the cortical surface and the subgaleal space. The devices detect normal physiologic and epileptiform activity, both in acute and chronic recordings. Comparative studies show sensor performance comparable to standard clinical systems and reduced tissue reactivity relative to conventional clinical electrocorticography (ECoG) electrodes. This technology offers general applicability in neural interfaces, with additional potential utility in treatment of disorders where transient monitoring and modulation of physiologic function, implant integrity and tissue recovery or regeneration are required.

  15. Nonintrusive biological signal monitoring in a car to evaluate a driver's stress and health state.

    PubMed

    Baek, Hyun Jae; Lee, Haet Bit; Kim, Jung Soo; Choi, Jong Min; Kim, Ko Keun; Park, Kwang Suk

    2009-03-01

    Nonintrusive monitoring of a driver's physiological signals was introduced and evaluated in a car as a test of extending the concept of ubiquitous healthcare to vehicles. Electrocardiogram, photoplethysmogram, galvanic skin response, and respiration were measured in the ubiquitous healthcare car (U-car) using nonintrusively installed sensors on the steering wheel, driver's seat, and seat belt. Measured signals were transmitted to the embedded computer via Bluetooth(R) communication and processed. We collected and analyzed physiological signals during driving in order to estimate a driver's stress state while using this system. In order to compare the effect of stress on physical and mental conditions, two categories of stresses were defined. Experimental results show that a driver's physiological signals were measured with acceptable quality for analysis without interrupting driving, and they were changed meaningfully due to elicited stress. This nonintrusive monitoring can be used to evaluate a driver's state of health and stress.

  16. EVA Physiology, Systems and Performance [EPSP] Project

    NASA Technical Reports Server (NTRS)

    Gernhardt, Michael L.

    2010-01-01

    This viewgraph presentation gives a general overview of the biomedical and technological challenges of Extravehicular Activity (EVA). The topics covered include: 1) Prebreathe Protocols; 2) Lunar Suit Testing and Development; and 3) Lunar Electric Rover and Exploration Operations Concepts.

  17. Impact of a monitored program of care on incidence of ventilator-associated pneumonia: results of a longterm performance-improvement project.

    PubMed

    Weireter, Leonard J; Collins, J N; Britt, Rebecca C; Reed, Scott F; Novosel, T J; Britt, L D

    2009-05-01

    Ventilator-associated pneumonia (VAP) remains a major source of morbidity, mortality, and expense in the ICU despite therapies directed against it. A retrospective review of a prospectively developed performance-improvement project monitoring the incidence of VAP in two adjacent ICUs was conducted. In response to an excessive VAP rate, weekly multidisciplinary team meetings were instituted to review data, develop care protocols, and modify care routines. Protocol compliance was monitored daily and feedback provided weekly to the care teams. VAP rates were determined by the institutional Infection Control Committee and reviewed monthly with the ICU multidisciplinary team. Duration of the investigational period was 10 years. A standardized ventilator-weaning protocol was instituted with confirmed 95% use. Additional modifications of care, such as patient positioning, use of specific endotracheal tubes to minimize aspiration of supraglottic secretions, an oral-care regimen, and aggressive antibiotic stewardship were standardized, with a compliance rate >90%. VAP rates dropped from 12.8 per 1,000 patient-days in 1998 to 1.1 in 2007 in the burn trauma ICU and from 21.2 to <1 in the neurotrauma ICU in the same time frame. Also, mean ventilator length of stay decreased from 6 days to 4.2 and from 5.8 days to 4.75 simultaneously in the respective ICUs. Such performance improvement has been sustained since implementation of the program. A systematic, monitored program of standardized care protocols can markedly reduce VAP rate in the ICU.

  18. Secure Authentication for Remote Patient Monitoring with Wireless Medical Sensor Networks †

    PubMed Central

    Hayajneh, Thaier; Mohd, Bassam J; Imran, Muhammad; Almashaqbeh, Ghada; Vasilakos, Athanasios V.

    2016-01-01

    There is broad consensus that remote health monitoring will benefit all stakeholders in the healthcare system and that it has the potential to save billions of dollars. Among the major concerns that are preventing the patients from widely adopting this technology are data privacy and security. Wireless Medical Sensor Networks (MSNs) are the building blocks for remote health monitoring systems. This paper helps to identify the most challenging security issues in the existing authentication protocols for remote patient monitoring and presents a lightweight public-key-based authentication protocol for MSNs. In MSNs, the nodes are classified into sensors that report measurements about the human body and actuators that receive commands from the medical staff and perform actions. Authenticating these commands is a critical security issue, as any alteration may lead to serious consequences. The proposed protocol is based on the Rabin authentication algorithm, which is modified in this paper to improve its signature signing process, making it suitable for delay-sensitive MSN applications. To prove the efficiency of the Rabin algorithm, we implemented the algorithm with different hardware settings using Tmote Sky motes and also programmed the algorithm on an FPGA to evaluate its design and performance. Furthermore, the proposed protocol is implemented and tested using the MIRACL (Multiprecision Integer and Rational Arithmetic C/C++) library. The results show that secure, direct, instant and authenticated commands can be delivered from the medical staff to the MSN nodes. PMID:27023540

  19. Secure Authentication for Remote Patient Monitoring with Wireless Medical Sensor Networks.

    PubMed

    Hayajneh, Thaier; Mohd, Bassam J; Imran, Muhammad; Almashaqbeh, Ghada; Vasilakos, Athanasios V

    2016-03-24

    There is broad consensus that remote health monitoring will benefit all stakeholders in the healthcare system and that it has the potential to save billions of dollars. Among the major concerns that are preventing the patients from widely adopting this technology are data privacy and security. Wireless Medical Sensor Networks (MSNs) are the building blocks for remote health monitoring systems. This paper helps to identify the most challenging security issues in the existing authentication protocols for remote patient monitoring and presents a lightweight public-key-based authentication protocol for MSNs. In MSNs, the nodes are classified into sensors that report measurements about the human body and actuators that receive commands from the medical staff and perform actions. Authenticating these commands is a critical security issue, as any alteration may lead to serious consequences. The proposed protocol is based on the Rabin authentication algorithm, which is modified in this paper to improve its signature signing process, making it suitable for delay-sensitive MSN applications. To prove the efficiency of the Rabin algorithm, we implemented the algorithm with different hardware settings using Tmote Sky motes and also programmed the algorithm on an FPGA to evaluate its design and performance. Furthermore, the proposed protocol is implemented and tested using the MIRACL (Multiprecision Integer and Rational Arithmetic C/C++) library. The results show that secure, direct, instant and authenticated commands can be delivered from the medical staff to the MSN nodes.

  20. Research on a Banknote Printing Wastewater Monitoring System based on Wireless Sensor Network

    NASA Astrophysics Data System (ADS)

    Li, B. B.; Yuan, Z. F.

    2006-10-01

    In this paper, a banknote printing wastewater monitoring system based on WSN is presented in line with the system demands and actual condition of the worksite for a banknote printing factory. In Physical Layer, the network node is a nRF9e5-centric embedded instrument, which can realize the multi-function such as data collecting, status monitoring, wireless data transmission and so on. Limited by the computing capability, memory capability, communicating energy and others factors, it is impossible for the node to get every detail information of the network, so the communication protocol on WSN couldn't be very complicated. The competitive-based MACA (Multiple Access with Collision Avoidance) Protocol is introduced in MAC, which can decide the communication process and working mode of the nodes, avoid the collision of data transmission, hidden and exposed station problem of nodes. On networks layer, the routing protocol in charge of the transmitting path of the data, the networks topology structure is arranged based on address assignation. Accompanied with some redundant nodes, the network performances stabile and expandable. The wastewater monitoring system is a tentative practice of WSN theory in engineering. Now, the system has passed test and proved efficiently.

  1. The Hawaii Protocol for Scientific Monitoring of Coffee Berry Borer: a Model for Coffee Agroecosystems Worldwide

    PubMed Central

    Johnson, Melissa Anne; Hollingsworth, Robert; Fortna, Samuel; Aristizábal, Luis F.; Manoukis, Nicholas C.

    2018-01-01

    Coffee berry borer (CBB) is the most devastating insect pest for coffee crops worldwide. We developed a scientific monitoring protocol that is aimed at capturing and quantifying the dynamics and impact of this invasive insect pest as well as the development of its host plant across a heterogeneous landscape. The cornerstone of this comprehensive monitoring system is timely georeferenced data collection on CBB movement, coffee berry infestation, mortality by the fungus Beauveria bassiana, and coffee plant phenology via a mobile electronic data recording application. This electronic data collection system allows field records to be georeferenced through built-in global positioning systems, and is backed by a network of weather stations and records of farm management practices. Comprehensive monitoring of CBB and host plant dynamics is an essential part of an area-wide project in Hawaii to aggregate landscape-level data for research to improve management practices. Coffee agroecosystems in other parts of the world that experience highly variable environmental and socioeconomic factors will also benefit from implementing this protocol, in that it will drive the development of customized integrated pest management (IPM) to manage CBB populations. PMID:29608152

  2. The Hawaii Protocol for Scientific Monitoring of Coffee Berry Borer: a Model for Coffee Agroecosystems Worldwide.

    PubMed

    Johnson, Melissa Anne; Hollingsworth, Robert; Fortna, Samuel; Aristizábal, Luis F; Manoukis, Nicholas C

    2018-03-19

    Coffee berry borer (CBB) is the most devastating insect pest for coffee crops worldwide. We developed a scientific monitoring protocol that is aimed at capturing and quantifying the dynamics and impact of this invasive insect pest as well as the development of its host plant across a heterogeneous landscape. The cornerstone of this comprehensive monitoring system is timely georeferenced data collection on CBB movement, coffee berry infestation, mortality by the fungus Beauveria bassiana, and coffee plant phenology via a mobile electronic data recording application. This electronic data collection system allows field records to be georeferenced through built-in global positioning systems, and is backed by a network of weather stations and records of farm management practices. Comprehensive monitoring of CBB and host plant dynamics is an essential part of an area-wide project in Hawaii to aggregate landscape-level data for research to improve management practices. Coffee agroecosystems in other parts of the world that experience highly variable environmental and socioeconomic factors will also benefit from implementing this protocol, in that it will drive the development of customized integrated pest management (IPM) to manage CBB populations.

  3. Effects of work-related sleep restriction on acute physiological and psychological stress responses and their interactions: A review among emergency service personnel.

    PubMed

    Wolkow, Alexander; Ferguson, Sally; Aisbett, Brad; Main, Luana

    2015-01-01

    Emergency work can expose personnel to sleep restriction. Inadequate amounts of sleep can negatively affect physiological and psychological stress responses. This review critiqued the emergency service literature (e.g., firefighting, police/law enforcement, defense forces, ambulance/paramedic personnel) that has investigated the effect of sleep restriction on hormonal, inflammatory and psychological responses. Furthermore, it investigated if a psycho-physiological approach can help contextualize the significance of such responses to assist emergency service agencies monitor the health of their personnel. The available literature suggests that sleep restriction across multiple work days can disrupt cytokine and cortisol levels, deteriorate mood and elicit simultaneous physiological and psychological responses. However, research concerning the interaction between such responses is limited and inconclusive. Therefore, it is unknown if a psycho-physiological relationship exists and as a result, it is currently not feasible for agencies to monitor sleep restriction related stress based on psycho- physiological interactions. Sleep restriction does however, appear to be a major stressor contributing to physiological and psychological responses and thus, warrants further investigation. This work is available in Open Access model and licensed under a CC BY-NC 3.0 PL license.

  4. Specialized physiological studies in support of manned space flight

    NASA Technical Reports Server (NTRS)

    Luft, U. C.

    1973-01-01

    The areas of physiological research reported include: (1) evaluation of the single-breath method for determining cardiac output, (2) optimum protocol for the assessment of cardio-pulmonary competence, (3) body fluids and electrolytes under conditions of single and combined stress, (4) re-evaluation of the open-circuit method for measuring metabolic rate with regard to the alleged metabolic production of gaseous nitrogen, and (5) the use of the forced-oscillation method to determine total respiratory conductance in healthy subjects and pulmonary patients.

  5. Chemostat Culture for Yeast Physiology.

    PubMed

    Kerr, Emily O; Dunham, Maitreya J

    2017-07-05

    The use of chemostat culture facilitates the careful comparison of different yeast strains growing in well-defined conditions. Variations in physiology can be measured by examining gene expression, metabolite levels, protein content, and cell morphology. In this protocol, we show how a combination of sample types can be collected during harvest from a single 20-mL chemostat in a ministat array, with special attention to coordinating the handling of the most time-sensitive sample types. © 2017 Cold Spring Harbor Laboratory Press.

  6. Nondestructive Methods for Monitoring Cell Removal During Rat Liver Decellularization.

    PubMed

    Geerts, Sharon; Ozer, Sinan; Jaramillo, Maria; Yarmush, Martin L; Uygun, Basak E

    2016-07-01

    Whole liver engineering holds the promise to create transplantable liver grafts that may serve as substitutes for donor organs, addressing the donor shortage in liver transplantation. While decellularization and recellularization of livers in animal models have been successfully achieved, scale up to human livers has been slow. There are a number of donor human livers that are discarded because they are not found suitable for transplantation, but are available for engineering liver grafts. These livers are rejected due to a variety of reasons, which in turn may affect the decellularization outcome. Hence, a one-size-fit-for all decellularization protocol may not result in scaffolds with consistent matrix quality, subsequently influencing downstream recellularization and transplantation outcomes. There is a need for a noninvasive monitoring method to evaluate the extent of cell removal, while ensuring preservation of matrix components during decellularization. In this study, we decellularized rat livers using a protocol previously established by our group, and we monitored decellularization through traditional destructive techniques, including evaluation of DNA, collagen, and glycosaminoglycan (GAG) content in decellularized scaffolds, as well as histology. In addition, we used computed tomography and perfusate analysis as alternative nondestructive decellularization monitoring methods. We found that DNA removal correlates well with the Hounsfield unit of the liver, and perfusate analysis revealed that significant amount of GAG is removed during perfusion with 0.1% sodium dodecyl sulfate. This allowed for optimization of our decellularization protocol leading to scaffolds that have significantly higher GAG content, while maintaining appropriate removal of cellular contents. The significance of this is the creation of a nondestructive monitoring strategy that can be used for optimization of decellularization protocols for individual human livers available for liver engineering.

  7. Nondestructive Methods for Monitoring Cell Removal During Rat Liver Decellularization

    PubMed Central

    Geerts, Sharon; Ozer, Sinan; Jaramillo, Maria; Yarmush, Martin L.

    2016-01-01

    Whole liver engineering holds the promise to create transplantable liver grafts that may serve as substitutes for donor organs, addressing the donor shortage in liver transplantation. While decellularization and recellularization of livers in animal models have been successfully achieved, scale up to human livers has been slow. There are a number of donor human livers that are discarded because they are not found suitable for transplantation, but are available for engineering liver grafts. These livers are rejected due to a variety of reasons, which in turn may affect the decellularization outcome. Hence, a one-size-fit-for all decellularization protocol may not result in scaffolds with consistent matrix quality, subsequently influencing downstream recellularization and transplantation outcomes. There is a need for a noninvasive monitoring method to evaluate the extent of cell removal, while ensuring preservation of matrix components during decellularization. In this study, we decellularized rat livers using a protocol previously established by our group, and we monitored decellularization through traditional destructive techniques, including evaluation of DNA, collagen, and glycosaminoglycan (GAG) content in decellularized scaffolds, as well as histology. In addition, we used computed tomography and perfusate analysis as alternative nondestructive decellularization monitoring methods. We found that DNA removal correlates well with the Hounsfield unit of the liver, and perfusate analysis revealed that significant amount of GAG is removed during perfusion with 0.1% sodium dodecyl sulfate. This allowed for optimization of our decellularization protocol leading to scaffolds that have significantly higher GAG content, while maintaining appropriate removal of cellular contents. The significance of this is the creation of a nondestructive monitoring strategy that can be used for optimization of decellularization protocols for individual human livers available for liver engineering. PMID:27169332

  8. Operational Implementation of a 2-Hour Prebreathe Protocol for International Space Station

    NASA Technical Reports Server (NTRS)

    Waligora, James M.; Conkin, J.; Foster, P. P.; Schneider, S.; Loftin, Karin C.; Gernhardt, Michael L.; Vann, R.

    2000-01-01

    Procedures, equipment, and analytical techniques were developed to implement the ground tested 2-hour protocol in-flight operations. The methods are: 1) The flight protocol incorporates additional safety margin over the ground tested protocol. This includes up to 20 min of additional time on enriched O2 during suit purge and pressure check, increased duration of extravehicular activity (EVA) preparation exercise during O2 prebreathing (up to 90 min vs; the tested 24 min), and reduced rates of depressurization. The ground test observations were combined with model projections of the conservative measures (using statistical models from Duke University and NASA JSQ to bound the risk of Type I and Type II decompression sickness (DCS). 2) An inflight exercise device using the in-flight ergometer and elastic tubes for upper body exercise was developed to replicate the dual cycle exercise in the ground trials. 3) A new in-flight breathing system was developed and man-tested. 4) A process to monitor inflight experience with the protocol, including the use of an in-suit Doppler bubble monitor when available, was developed. The results are: 1) The model projections of the conservative factors of the operational protocol were shown to reduce the risk of DCS to levels consistent with the observations of no DCS to date in the shuttle program. 2) Cross over trials of the dual cycle ergometer used in ground tests and the in-flight exercise system verified that02consumption and the % division of work between upper and lower body was not significantly different at the p= 0.05 level. 3) The in-flight breathing system was demonstrated to support work rates generating 75% O2(max) in 95 percentile subjects. 4) An in-flight monitoring plan with acceptance criteria was put in place for the 2-hour prebreathe protocol. And the conclusions are: The 2-hour protocol has been approved for flight, and all implementation efforts are in place to allow use of the protocol as early as flight ISS 7A, now scheduled in November of 2000.

  9. A new engineering approach to reveal correlation of physiological change and spontaneous expression from video images

    NASA Astrophysics Data System (ADS)

    Yang, Fenglei; Hu, Sijung; Ma, Xiaoyun; Hassan, Harnani; Wei, Dongqing

    2015-03-01

    Spontaneous expression is associated with physiological states, i.e., heart rate, respiration, oxygen saturation (SpO2%), and heart rate variability (HRV). There have yet not sufficient efforts to explore correlation of physiological change and spontaneous expression. This study aims to study how spontaneous expression is associated with physiological changes with an approved protocol or through the videos provided from Denver Intensity of Spontaneous Facial Action Database. Not like a posed expression, motion artefact in spontaneous expression is one of evitable challenges to be overcome in the study. To obtain a physiological signs from a region of interest (ROI), a new engineering approach is being developed with an artefact-reduction method consolidated 3D active appearance model (AAM) based track, affine transformation based alignment with opto-physiological mode based imaging photoplethysmography. Also, a statistical association spaces is being used to interpret correlation of spontaneous expressions and physiological states including their probability densities by means of Gaussian Mixture Model. The present work is revealing a new avenue of study associations of spontaneous expressions and physiological states with its prospect of applications on physiological and psychological assessment.

  10. Development and Application of a Virtual Screening Protocol for the Identification of Multitarget Fragments.

    PubMed

    Bottegoni, Giovanni; Veronesi, Marina; Bisignano, Paola; Kacker, Puneet; Favia, Angelo D; Cavalli, Andrea

    2016-06-20

    In this study, we report on a virtual ligand screening protocol optimized to identify fragments endowed with activity at multiple targets. Thanks to this protocol, we were able to identify a fragment that displays activity in the low-micromolar range at both β-secretase 1 (BACE-1) and glycogen synthase kinase 3β (GSK-3β). These two structurally and physiologically unrelated enzymes likely contribute, through different pathways, to the onset of Alzheimer's disease (AD). Therefore, their simultaneous inhibition holds great potential in exerting a profound effect on AD. In perspective, the strategy outlined herein can be adapted to other target combinations. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  11. Biomedical Monitoring By A Novel Noncontact Radio Frequency Technology Project

    NASA Technical Reports Server (NTRS)

    Oliva-Buisson, Yvette J. (Compiler)

    2014-01-01

    The area of Space Health and Medicine is one of the NASA's Space Technology Grand Challenges. Space is an extreme environment which is not conducive to human life. The extraterrestrial environment can result in the deconditioning of various human physiological systems and thus require easy to use physiological monitoring technologies in order to better monitor space crews for appropriate health management and successful space missions and space operations. Furthermore, the Space Technology Roadmap's Technology Area Breakdown Structure calls for improvements in research to support human health and performance (Technology Area 06). To address these needs, this project investigated a potential noncontact and noninvasive radio frequency-based technique of monitoring central hemodynamic function in human research subjects in response to orthostatic stress.

  12. Daily Physical Activity and Hot Flashes in the Study of Women's Health Across the Nation FLASHES Study

    PubMed Central

    Gibson, Carolyn; Matthews, Karen; Thurston, Rebecca

    2014-01-01

    Objective To examine the role of physical activity in menopausal hot flashes. Competing models conceptualize physical activity as a risk or protective factor for hot flashes. Few studies have examined this relationship prospectively using physiologic measures of hot flashes and physical activity. Design Over two 48 hour-periods, 51 participants wore a physiologic hot flash monitor and activity monitor, and reported their hot flashes in an electronic diary. Physiologic hot flashes, reported hot flashes and reported hot flashes without physiological corroboration were related to activity changes using hierarchical generalized linear modeling, adjusting for potential confounders. Setting Community. Patients Midlife women. Interventions None. Main Outcome Measures Physiologically-detected hot flashes and reported hot flashes with and without physiologic corroboration. Results Hot flash reports without physiologic corroboration were more likely after activity increases (OR 1.04, 95% CI: 1.00-1.10, p=.01), particularly among women with higher levels of depressive symptoms (interaction p=.02). No other types of hot flashes were related to physical activity. Conclusion Acute increases in physical activity were associated with increased reporting of hot flashes lacking physiologic corroboration, particularly among women with depressive symptoms. Clinicians should consider the role of symptom perception and reporting in relations between physical activity and hot flashes. PMID:24491454

  13. The role of the Data and Safety Monitoring Board in a clinical trial: the CRISIS study.

    PubMed

    Holubkov, Richard; Casper, T Charles; Dean, J Michael; Anand, K J S; Zimmerman, Jerry; Meert, Kathleen L; Newth, Christopher J L; Berger, John; Harrison, Rick; Willson, Douglas F; Nicholson, Carol

    2013-05-01

    Randomized clinical trials are commonly overseen by a Data and Safety Monitoring Board comprised of experts in medicine, ethics, and biostatistics. Data and Safety Monitoring Board responsibilities include protocol approval, interim review of study enrollment, protocol compliance, safety, and efficacy data. Data and Safety Monitoring Board decisions can affect study design and conduct, as well as reported findings. Researchers must incorporate Data and Safety Monitoring Board oversight into the design, monitoring, and reporting of randomized trials. Case study, narrative review. The Data and Safety Monitoring Board's role during the comparative pediatric Critical Illness Stress-Induced Immune Suppression (CRISIS) Prevention Trial is described. The National Institutes of Health-appointed CRISIS Data and Safety Monitoring Board was charged with monitoring sample size adequacy and feasibility, safety with respect to adverse events and 28-day mortality, and efficacy with respect to the primary nosocomial infection/sepsis outcome. The Federal Drug Administration also requested Data and Safety Monitoring Board interim review before opening CRISIS to children below 1 yr of age. The first interim analysis found higher 28-day mortality in one treatment arm. The Data and Safety Monitoring Board maintained trial closure to younger children and requested a second interim data review 6 months later. At this second meeting, mortality was no longer of concern, whereas a weak efficacy trend of lower infection/sepsis rates in one study arm emerged. As over 40% of total patients had been enrolled, the Data and Safety Monitoring Board elected to examine conditional power and unmask treatment arm identities. On finding somewhat greater efficacy in the placebo arm, the Data and Safety Monitoring Board recommended stopping CRISIS due to futility. The design and operating procedures of a multicenter randomized trial must consider a pivotal Data and Safety Monitoring Board role. Maximum study design flexibility must be allowed, and investigators must be prepared for protocol modifications due to interim findings. The Data and Safety Monitoring Board must have sufficient clinical and statistical expertise to assess potential importance of interim treatment differences in the setting of multiple looks at accumulating data with numerous outcomes and subgroups.

  14. Electrophysiology of Intuition: Pre-stimulus Responses in Group and Individual Participants Using a Roulette Paradigm

    PubMed Central

    Atkinson, Mike

    2014-01-01

    This study used electrophysiological measures of pre-stimulus effects that can occur prior to an unknown future event as an indicator of nonlocal intuition. Intuition in this context is considered as a process by which information normally outside the range of conscious awareness is detected at the cellular level by the heart, the brain, and the autonomic nervous system. This study extends the findings of previous experiments demonstrating that aspects of our physiology can respond to an emotionally engaging stimulus before it is actually experienced. The study evaluated a revised version of a roulette protocol, which included two pre-stimulus segments and included an analysis of the individual participant's data over eight separate trials in addition to a group-level analysis. We also assessed the potential effects of the moon phase on the pre-stimulus response outcomes and participant winning and amount won ratios. Data were collected under controlled laboratory conditions from 13 participants in 8 separate sessions using a modified version of a gambling paradigm protocol based on roulette. Half of the experimental sessions were conducted during the full moon phase and half during the new moon phase. Within each trial a total of three segments of physiological data were assessed. There were two separate pre-stimulus periods, pre-bet (4 sec) and postbet (12 sec), and a post-result period (6 sec). Participants were told that they were participating in a gambling experiment and were given an initial starting kitty and told they could keep any winnings over the course of 26 trials for each of the eight sessions. The physiological measures included the electrocardiogram (ECG), from which cardiac inter-beat-intervals (heart rate variability, HRV) were derived, and skin conductance. Before the participants participated in the first session, they completed the Cognitive Styles Index questionnaire, which assesses analytical vs intuitive styles. Overall, the results indicate that the revised protocol provides an effective objective measure for detecting a pre-stimulus response, which reflects a type of nonlocal intuition. We found significant differences between the win and loss responses in the aggregated physiological waveform data during both pre-stimulus segments, which provides important information about nonlocal intuition. On average, we detected a significant pre-stimulus response starting around 18 seconds prior to participants knowing the future outcome. Interestingly, there was not a strong overall relationship between the pre-stimulus responses and the amount of money the participants won or lost. We also found a significant difference in both pre-stimulus periods during the full moon phase but not in the new moon phase. The results suggest that the protocol is a reliable means of prompting physiological detection of pre-stimulus effects and can be used in future studies investigating aspects of nonlocal intuition. The findings also suggest that if participants had been able to become more attuned to their internal physiological responses, they would have performed much better on the betting choices they made. PMID:24808978

  15. Micro-patterned graphene-based sensing skins for human physiological monitoring

    NASA Astrophysics Data System (ADS)

    Wang, Long; Loh, Kenneth J.; Chiang, Wei-Hung; Manna, Kausik

    2018-03-01

    Ultrathin, flexible, conformal, and skin-like electronic transducers are emerging as promising candidates for noninvasive and nonintrusive human health monitoring. In this work, a wearable sensing membrane is developed by patterning a graphene-based solution onto ultrathin medical tape, which can then be attached to the skin for monitoring human physiological parameters and physical activity. Here, the sensor is validated for monitoring finger bending/movements and for recognizing hand motion patterns, thereby demonstrating its future potential for evaluating athletic performance, physical therapy, and designing next-generation human-machine interfaces. Furthermore, this study also quantifies the sensor’s ability to monitor eye blinking and radial pulse in real-time, which can find broader applications for the healthcare sector. Overall, the printed graphene-based sensing skin is highly conformable, flexible, lightweight, nonintrusive, mechanically robust, and is characterized by high strain sensitivity.

  16. An efficient and secure certificateless authentication protocol for healthcare system on wireless medical sensor networks.

    PubMed

    Guo, Rui; Wen, Qiaoyan; Jin, Zhengping; Zhang, Hua

    2013-01-01

    Sensor networks have opened up new opportunities in healthcare systems, which can transmit patient's condition to health professional's hand-held devices in time. The patient's physiological signals are very sensitive and the networks are extremely vulnerable to many attacks. It must be ensured that patient's privacy is not exposed to unauthorized entities. Therefore, the control of access to healthcare systems has become a crucial challenge. An efficient and secure authentication protocol will thus be needed in wireless medical sensor networks. In this paper, we propose a certificateless authentication scheme without bilinear pairing while providing patient anonymity. Compared with other related protocols, the proposed scheme needs less computation and communication cost and preserves stronger security. Our performance evaluations show that this protocol is more practical for healthcare system in wireless medical sensor networks.

  17. An Efficient and Secure Certificateless Authentication Protocol for Healthcare System on Wireless Medical Sensor Networks

    PubMed Central

    Guo, Rui; Wen, Qiaoyan; Jin, Zhengping; Zhang, Hua

    2013-01-01

    Sensor networks have opened up new opportunities in healthcare systems, which can transmit patient's condition to health professional's hand-held devices in time. The patient's physiological signals are very sensitive and the networks are extremely vulnerable to many attacks. It must be ensured that patient's privacy is not exposed to unauthorized entities. Therefore, the control of access to healthcare systems has become a crucial challenge. An efficient and secure authentication protocol will thus be needed in wireless medical sensor networks. In this paper, we propose a certificateless authentication scheme without bilinear pairing while providing patient anonymity. Compared with other related protocols, the proposed scheme needs less computation and communication cost and preserves stronger security. Our performance evaluations show that this protocol is more practical for healthcare system in wireless medical sensor networks. PMID:23710147

  18. Bio-integrated electronics and sensor systems

    NASA Astrophysics Data System (ADS)

    Yeo, Woon-Hong; Webb, R. Chad; Lee, Woosik; Jung, Sungyoung; Rogers, John A.

    2013-05-01

    Skin-mounted epidermal electronics, a strategy for bio-integrated electronics, provide an avenue to non-invasive monitoring of clinically relevant physiological signals for healthcare applications. Current conventional systems consist of single-point sensors fastened to the skin with adhesives, and sometimes with conducting gels, which limits their use outside of clinical settings due to loss of adhesion and irritation to the user. In order to facilitate extended use of skin-mounted healthcare sensors without disrupting everyday life, we envision electronic monitoring systems that integrate seamlessly with the skin below the notice of the user. This manuscript reviews recent significant results towards our goal of wearable electronic sensor systems for long-term monitoring of physiological signals. Ultra-thin epidermal electronic systems (EES) are demonstrated for extended use on the skin, in a conformal manner, including during everyday bathing and sleeping activities. We describe the assessment of clinically relevant physiological parameters, such as electrocardiograms (ECG), electromyograms (EMG), electroencephalograms (EEG), temperature, mechanical strain and thermal conductivity, using examples of multifunctional EES devices. Additionally, we demonstrate capability for real life application of EES by monitoring the system functionality, which has no discernible change, during cyclic fatigue testing.

  19. Phenology monitoring protocol: Northeast Temperate Network

    USGS Publications Warehouse

    Tierney, Geri; Mitchell, Brian; Miller-Rushing, Abraham J.; Katz, Jonathan; Denny, Ellen; Brauer, Corinne; Donovan, Therese; Richardson, Andrew D.; Toomey, Michael; Kozlowski, Adam; Weltzin, Jake F.; Gerst, Kathy; Sharron, Ed; Sonnentag, Oliver; Dieffenbach, Fred

    2013-01-01

    historical parks and national historic sites in the northeastern US. This protocol was developed in collaboration with and relies upon the procedures and infrastructure of the USA National Phenology Network (USA-NPN), including Nature’s Notebook, USA-NPN’s online plant and animal phenology observation program (www.nn.usanpn.org). Organized in 2007, USA-NPN is a nation-wide partnership among federal agencies, schools and universities, citizen volunteers, and others to monitor and understand the influence of seasonal cycles on the nation’s biological resources. The overall goal of NETN’s phenology monitoring program is to determine trends in the phenology of key species in order to assist park managers with the detection and mitigation of the effects of climate change on park resources. An additional programmatic goal is to interest and educate park visitors and staff, as well as a cadre of volunteer monitors.

  20. Research on human physiological parameters intelligent clothing based on distributed Fiber Bragg Grating

    NASA Astrophysics Data System (ADS)

    Miao, Changyun; Shi, Boya; Li, Hongqiang

    2008-12-01

    A human physiological parameters intelligent clothing is researched with FBG sensor technology. In this paper, the principles and methods of measuring human physiological parameters including body temperature and heart rate in intelligent clothing with distributed FBG are studied, the mathematical models of human physiological parameters measurement are built; the processing method of body temperature and heart rate detection signals is presented; human physiological parameters detection module is designed, the interference signals are filtered out, and the measurement accuracy is improved; the integration of the intelligent clothing is given. The intelligent clothing can implement real-time measurement, processing, storage and output of body temperature and heart rate. It has accurate measurement, portability, low cost, real-time monitoring, and other advantages. The intelligent clothing can realize the non-contact monitoring between doctors and patients, timely find the diseases such as cancer and infectious diseases, and make patients get timely treatment. It has great significance and value for ensuring the health of the elders and the children with language dysfunction.

  1. TH-C-18A-08: A Management Tool for CT Dose Monitoring, Analysis, and Protocol Review

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, J; Chan, F; Newman, B

    2014-06-15

    Purpose: To develop a customizable tool for enterprise-wide managing of CT protocols and analyzing radiation dose information of CT exams for a variety of quality control applications Methods: All clinical CT protocols implemented on the 11 CT scanners at our institution were extracted in digital format. The original protocols had been preset by our CT management team. A commercial CT dose tracking software (DoseWatch,GE healthcare,WI) was used to collect exam information (exam date, patient age etc.), scanning parameters, and radiation doses for all CT exams. We developed a Matlab-based program (MathWorks,MA) with graphic user interface which allows to analyze themore » scanning protocols with the actual dose estimates, and compare the data to national (ACR,AAPM) and internal reference values for CT quality control. Results: The CT protocol review portion of our tool allows the user to look up the scanning and image reconstruction parameters of any protocol on any of the installed CT systems among about 120 protocols per scanner. In the dose analysis tool, dose information of all CT exams (from 05/2013 to 02/2014) was stratified on a protocol level, and within a protocol down to series level, i.e. each individual exposure event. This allows numerical and graphical review of dose information of any combination of scanner models, protocols and series. The key functions of the tool include: statistics of CTDI, DLP and SSDE, dose monitoring using user-set CTDI/DLP/SSDE thresholds, look-up of any CT exam dose data, and CT protocol review. Conclusion: our inhouse CT management tool provides radiologists, technologists and administration a first-hand near real-time enterprise-wide knowledge on CT dose levels of different exam types. Medical physicists use this tool to manage CT protocols, compare and optimize dose levels across different scanner models. It provides technologists feedback on CT scanning operation, and knowledge on important dose baselines and thresholds.« less

  2. VO2max Testing in Trail Runners: Is There a Specific Exercise Test Protocol?

    PubMed

    Scheer, Volker; Ramme, Katharina; Reinsberger, Claus; Heitkamp, Hans-Christian

    2018-06-01

    Trail running places specific physiological demands on the human body due to its uphill and downhill running sections. We developed and investigated a more sport-specific trail exercise test protocol (inclination and speed incremental protocol), and compared it to two standard exercise test protocols (horizontal step and ramp protocol) in thirteen highly trained trail runners (age 31±6 years, height 179±6.4 cm, weight 69.2±7.9 kg, BMI 21.6±2.1 kg/m 2 ). The maximum oxygen uptake (VO 2 max) measured during the trail test (62.5±5.9 ml·kg -1 ·min -1 , [95% CI: 59.0-66.1]) was significantly higher compared to both the step test (60.1±5.3 ml·kg -1 ·min -1 , [95% CI: 56.8-63.3], p=0.024) and the ramp test (59.7±5.5 ml·kg -1 ·min -1 , [95% CI: 56.4-63.0], p=0.028). Time to task failure was significantly shorter in the trail test (557±73 s, [95% CI: 512-601]) compared to both the step test (1378±152 s, [95% CI: 1286-1470], p<0.001) and the ramp test (605±95, [95% CI: 547-662], p<0.001). Other physiological measurements obtained were similar. The trail test was the preferred choice in our group of trail runners. This study supports the implementation of the trail test in practice, and recommends that its validity be evaluated further. © Georg Thieme Verlag KG Stuttgart · New York.

  3. Treatment of antipsychotic-associated obesity with a GLP-1 receptor agonist—protocol for an investigator-initiated prospective, randomised, placebo-controlled, double-blinded intervention study: the TAO study protocol

    PubMed Central

    Ishøy, Pelle L; Knop, Filip K; Broberg, Brian V; Baandrup, Lone; Fagerlund, Birgitte; Jørgensen, Niklas R; Andersen, Ulrik B; Rostrup, Egill; Glenthøj, Birte Y; Ebdrup, Bjørn H

    2014-01-01

    Introduction Antipsychotic medication is widely associated with dysmetabolism including obesity and type 2 diabetes, cardiovascular-related diseases and early death. Obesity is considered the single most important risk factor for cardiovascular morbidity and mortality. Interventions against antipsychotic-associated obesity are limited and insufficient. Glucagon-like peptide-1 (GLP-1) receptor agonists are approved for the treatment of type 2 diabetes, but their bodyweight-lowering effects have also been recognised in patients with non-diabetes. The primary endpoint of this trial is weight loss after 3 months of treatment with a GLP-1 receptor agonist (exenatide once weekly) in patients with non-diabetic schizophrenia with antipsychotic-associated obesity. Secondary endpoints include physiological and metabolic measurements, various psychopathological and cognitive measures, and structural and functional brain MRI. Methods and analysis 40 obese patients with schizophrenia or schizoaffective disorder treated with antipsychotic drugs will be randomised to subcutaneous injection of exenatide once weekly (2 mg) or placebo for 3 months, adjunctive to their antipsychotic treatment. Ethics and dissemination The trial has been approved by the Danish Health and Medicines Authority, the National Committee on Health Research Ethics and the Danish Data Protection Agency. Trial participation presupposes theoral and written patient informed consent. An external, independent monitoring committee (Good Clinical Practice Unit at Copenhagen University Hospital) will monitor the study according to the GCP Guidelines. Trial data, including positive, negative and inconclusive results, will be presented at national and international scientific meetings and conferences. Papers will be submitted to peer-reviewed journals. Trial registration ClinicalTrials.gov identifier: NCT01794429; National Committee on Health Research Ethics project number: 36378; EudraCT nr: 2012-005404-17; The Danish Data Protection Agency project number: RHP-2012-027. PMID:24401727

  4. Enhanced Characterization of Microorganisms in the Spacecraft Environment

    NASA Technical Reports Server (NTRS)

    Cruz, Patricia; Stetzenbach, Linda D.

    2004-01-01

    Spacecraft such as the International Space Station (ISS) and the space shuttles are enclosed environments where crewmembers may spend long periods of time. Currently, crewmembers spend approximately a period of 6 months in the ISS. It is known that these prolonged stays in space may result in weakening of the immune system. Therefore, exposure to opportunistic pathogens or high concentrations of environmental microorganisms may compromise the health of the crew. The detection of biocontaminants in spacecraft environments utilizes culture-based methodology, omitting greater than 90% of all microorganisms including pathogens such as Legionella and Cryptosporidium. Culturable bacteria and fungi have been the only allergens studied; the more potent allergens, such as those from dust mites, have never been tested for in spacecraft environments. In addition, no attempts have been made to monitor microbial toxins in spacecrafts. The present study utilized quantitative polymerase chain reaction (QPCR) as a novel approach for monitoring microorganisms in the spacecraft environment. QPCR is a molecular biology technique that does not rely on the physiological state of the organisms for identification, thereby enabling detection of both culturable and non-culturable organisms. In this project, specific molecular primers and probes were utilized for the detection and quantitation of two fungi of concern in indoor environments, Aspergillus fumigatus and Stachybotrys chartarum. These organisms were selected because of the availability of PCR primers and probes, and to establish the sample processing and analysis methodology that may be employed with additional organisms. Purification methods and QPCR assays were optimized for the detection of these organisms in air, surface, and water; and sample processing and analysis protocols were developed. Preliminary validation of these protocols was conducted in the laboratory with air, surface, and water samples seeded with known concentrations of the target organisms. Additional studies were conducted with bulk materials (HEPA filter pleats and particulate found on the filter screen) obtained from the ISS.

  5. Mental Fatigue and Physical and Cognitive Performance During a 2-Bout Exercise Test.

    PubMed

    Vrijkotte, Susan; Meeusen, Romain; Vandervaeren, Cloe; Buyse, Luk; Cutsem, Jeroen van; Pattyn, Nathalie; Roelands, Bart

    2018-04-01

    The 2-bout exercise protocol has been developed to diagnose nonfunctional overreaching and the "overtraining syndrome." It consists of 2 maximal exercise bouts separated by 4 hours. Mental fatigue negatively influences performance, but the effects of its occurrence during the 2-bout exercise protocol have never been investigated. The aim of this study was to examine whether mental fatigue (induced during the rest period) influences physical and cognitive performance during/after the second exercise bout of the 2-bout exercise protocol. Nine healthy, well-trained male cyclists participated in a single-blind, randomized, placebo-controlled crossover study. The intervention consisted of either 1.5-hour rest (control) or performing a computer-based Stroop task to induce mental fatigue. Cognitive (Eriksen Flanker task), physiological (lactate, maximum heart rate, and maximum wattage), and subjective data (mental fatigue-visual analog scale, Profile of Mood States, and rating of perceived exertion) were gathered. Ratings of fatigue, tension, and mental fatigue were affected in the mental fatigue condition (P < .05). Neither physiological nor cognitive differences were found between conditions. Ratings of mental fatigue were already affected after the first maximum exercise test (P < .05). Neither physical nor cognitive performance was affected by mental fatigue, but subjective ratings did reveal significant differences. It is recommended to exclude mentally challenging tasks during the 2-bout exercise protocol rest period to ascertain unaffected subjective test results. This study should be repeated in athletes diagnosed with nonfunctional overreaching/overtraining syndrome.

  6. Soil quality monitoring: Examples of existing protocols

    Treesearch

    Daniel G. Neary; Carl C. Trettin; Deborah Page-Dumroese

    2010-01-01

    Many forestry and agricultural agencies and organizations worldwide have developed soil monitoring and quality standards and guidelines to ensure future sustainability of land management. These soil monitoring standards are typically developed in response to international initiatives such as the Montreal Process, the Helsinki Ministerial Conference,or in support of...

  7. Soil quality monitoring: examples of existing protocols

    Treesearch

    Daniel G. Neary; Carl C. Trettin; Deborah Page-Dumroese

    2010-01-01

    Many forestry and agricultural agencies and organizations worldwide have developed soil monitoring and quality standards and guidelines to ensure future sustainability of land management. These soil monitoring standards are typically developed in response to international initiatives such as the Montreal Process, the Helsinki Ministerial Conference, or in support of...

  8. Watching what widlife want and need

    Treesearch

    Natasha Vizcarra; Mary Rowland; Christina Vojta

    2016-01-01

    National forests and grasslands are home to a diverse array of wildlife. To keep tabs on the general viability and wellbeing of these inhabitants, land managers need practical, defensible monitoring protocols. Population monitoring is one method. Another is habitat monitoring, which provides critical information about the quantity and quality of key habitat attributes...

  9. 300 area TEDF NPDES Permit Compliance Monitoring Plan

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Loll, C.M.

    1995-09-05

    This document presents the 300 Area Treated Effluent Disposal Facility (TEDF) National Pollutant Discharge Elimination System (NPDES) Permit Compliance Monitoring Plan (MP). The MP describes how ongoing monitoring of the TEDF effluent stream for compliance with the NPDES permit will occur. The MP also includes Quality Assurance protocols to be followed.

  10. Adolescent pedometer protocols: examining reactivity, tampering and participants' perceptions.

    PubMed

    Scott, Joseph John; Morgan, Philip James; Plotnikoff, Ronald Cyril; Trost, Stewart Graeme; Lubans, David Revalds

    2014-01-01

    The aim of this study was to investigate adolescents' potential reactivity and tampering while wearing pedometers by comparing different monitoring protocols to accelerometer output. The sample included adolescents (N = 123, age range = 14-15 years) from three secondary schools in New South Wales, Australia. Schools were randomised to one of the three pedometer monitoring protocols: (i) daily sealed (DS) pedometer group, (ii) unsealed (US) pedometer group or (iii) weekly sealed (WS) pedometer group. Participants wore pedometers (Yamax Digi-Walker CW700, Yamax Corporation, Kumamoto City, Japan) and accelerometers (Actigraph GT3X+, Pensacola, USA) simultaneously for seven days. Repeated measures analysis of variance was used to examine potential reactivity. Bivariate correlations between step counts and accelerometer output were calculated to explore potential tampering. The correlation between accelerometer output and pedometer steps/day was strongest among participants in the WS group (r = 0.82, P ≤ 0.001), compared to the US (r = 0.63, P ≤ 0.001) and DS (r = 0.16, P = 0.324) groups. The DS (P ≤ 0.001) and US (P = 0.003), but not the WS (P = 0.891), groups showed evidence of reactivity. The results suggest that reactivity and tampering does occur in adolescents and contrary to existing research, pedometer monitoring protocols may influence participant behaviour.

  11. Attacks exploiting deviation of mean photon number in quantum key distribution and coin tossing

    NASA Astrophysics Data System (ADS)

    Sajeed, Shihan; Radchenko, Igor; Kaiser, Sarah; Bourgoin, Jean-Philippe; Pappa, Anna; Monat, Laurent; Legré, Matthieu; Makarov, Vadim

    2015-03-01

    The security of quantum communication using a weak coherent source requires an accurate knowledge of the source's mean photon number. Finite calibration precision or an active manipulation by an attacker may cause the actual emitted photon number to deviate from the known value. We model effects of this deviation on the security of three quantum communication protocols: the Bennett-Brassard 1984 (BB84) quantum key distribution (QKD) protocol without decoy states, Scarani-Acín-Ribordy-Gisin 2004 (SARG04) QKD protocol, and a coin-tossing protocol. For QKD we model both a strong attack using technology possible in principle and a realistic attack bounded by today's technology. To maintain the mean photon number in two-way systems, such as plug-and-play and relativistic quantum cryptography schemes, bright pulse energy incoming from the communication channel must be monitored. Implementation of a monitoring detector has largely been ignored so far, except for ID Quantique's commercial QKD system Clavis2. We scrutinize this implementation for security problems and show that designing a hack-proof pulse-energy-measuring detector is far from trivial. Indeed, the first implementation has three serious flaws confirmed experimentally, each of which may be exploited in a cleverly constructed Trojan-horse attack. We discuss requirements for a loophole-free implementation of the monitoring detector.

  12. [A wireless mobile monitoring system based on bluetooth technology].

    PubMed

    Sun, Shou-jun; Wu, Kai; Wu, Xiao-Ming

    2006-09-01

    This paper presents a wireless mobile monitoring system based on Bluetooth technology. This system realizes the remote mobile monitoring of multiple physiological parameters, and has the characters of easy use, low cost, good reliability and strong capability of anti-jamming.

  13. A low-power multi-modal body sensor network with application to epileptic seizure monitoring.

    PubMed

    Altini, Marco; Del Din, Silvia; Patel, Shyamal; Schachter, Steven; Penders, Julien; Bonato, Paolo

    2011-01-01

    Monitoring patients' physiological signals during their daily activities in the home environment is one of the challenge of the health care. New ultra-low-power wireless technologies could help to achieve this goal. In this paper we present a low-power, multi-modal, wearable sensor platform for the simultaneous recording of activity and physiological data. First we provide a description of the wearable sensor platform, and its characteristics with respect to power consumption. Second we present the preliminary results of the comparison between our sensors and a reference system, on healthy subjects, to test the reliability of the detected physiological (electrocardiogram and respiration) and electromyography signals.

  14. Human Cognitive Limitations. Broad, Consistent, Clinical Application of Physiological Principles Will Require Decision Support.

    PubMed

    Morris, Alan H

    2018-02-01

    Our education system seems to fail to enable clinicians to broadly understand core physiological principles. The emphasis on reductionist science, including "omics" branches of research, has likely contributed to this decrease in understanding. Consequently, clinicians cannot be expected to consistently make clinical decisions linked to best physiological evidence. This is a large-scale problem with multiple determinants, within an even larger clinical decision problem: the failure of clinicians to consistently link their decisions to best evidence. Clinicians, like all human decision-makers, suffer from significant cognitive limitations. Detailed context-sensitive computer protocols can generate personalized medicine instructions that are well matched to individual patient needs over time and can partially resolve this problem.

  15. Wearable physiological systems and technologies for metabolic monitoring.

    PubMed

    Gao, Wei; Brooks, George A; Klonoff, David C

    2018-03-01

    Wearable sensors allow continuous monitoring of metabolites for diabetes, sports medicine, exercise science, and physiology research. These sensors can continuously detect target analytes in skin interstitial fluid (ISF), tears, saliva, and sweat. In this review, we will summarize developments on wearable devices and their potential applications in research, clinical practice, and recreational and sporting activities. Sampling skin ISF can require insertion of a needle into the skin, whereas sweat, tears, and saliva can be sampled by devices worn outside the body. The most widely sampled metabolite from a wearable device is glucose in skin ISF for monitoring diabetes patients. Continuous ISF glucose monitoring allows estimation of the glucose concentration in blood without the pain, inconvenience, and blood waste of fingerstick capillary blood glucose testing. This tool is currently used by diabetes patients to provide information for dosing insulin and determining a diet and exercise plan. Similar technologies for measuring concentrations of other analytes in skin ISF could be used to monitor athletes, emergency responders, warfighters, and others in states of extreme physiological stress. Sweat is a potentially useful substrate for sampling analytes for metabolic monitoring during exercise. Lactate, sodium, potassium, and hydrogen ions can be measured in sweat. Tools for converting the concentrations of these analytes sampled from sweat, tears, and saliva into blood concentrations are being developed. As an understanding of the relationships between the concentrations of analytes in blood and easily sampled body fluid increases, then the benefits of new wearable devices for metabolic monitoring will also increase.

  16. Lateralization of spatial information processing in response monitoring

    PubMed Central

    Stock, Ann-Kathrin; Beste, Christian

    2014-01-01

    The current study aims at identifying how lateralized multisensory spatial information processing affects response monitoring and action control. In a previous study, we investigated multimodal sensory integration in response monitoring processes using a Simon task. Behavioral and neurophysiologic results suggested that different aspects of response monitoring are asymmetrically and independently allocated to the hemispheres: while efference-copy-based information on the motor execution of the task is further processed in the hemisphere that originally generated the motor command, proprioception-based spatial information is processed in the hemisphere contralateral to the effector. Hence, crossing hands (entering a “foreign” spatial hemifield) yielded an augmented bilateral activation during response monitoring since these two kinds of information were processed in opposing hemispheres. Because the traditional Simon task does not provide the possibility to investigate which aspect of the spatial configuration leads to the observed hemispheric allocation, we introduced a new “double crossed” condition that allows for the dissociation of internal/physiological and external/physical influences on response monitoring processes. Comparing behavioral and neurophysiologic measures of this new condition to those of the traditional Simon task setup, we could demonstrate that the egocentric representation of the physiological effector's spatial location accounts for the observed lateralization of spatial information in action control. The finding that the location of the physical effector had a very small influence on response monitoring measures suggests that this aspect is either less important and/or processed in different brain areas than egocentric physiological information. PMID:24550855

  17. Protocol for Microplastics Sampling on the Sea Surface and Sample Analysis

    PubMed Central

    Kovač Viršek, Manca; Palatinus, Andreja; Koren, Špela; Peterlin, Monika; Horvat, Petra; Kržan, Andrej

    2016-01-01

    Microplastic pollution in the marine environment is a scientific topic that has received increasing attention over the last decade. The majority of scientific publications address microplastic pollution of the sea surface. The protocol below describes the methodology for sampling, sample preparation, separation and chemical identification of microplastic particles. A manta net fixed on an »A frame« attached to the side of the vessel was used for sampling. Microplastic particles caught in the cod end of the net were separated from samples by visual identification and use of stereomicroscopes. Particles were analyzed for their size using an image analysis program and for their chemical structure using ATR-FTIR and micro FTIR spectroscopy. The described protocol is in line with recommendations for microplastics monitoring published by the Marine Strategy Framework Directive (MSFD) Technical Subgroup on Marine Litter. This written protocol with video guide will support the work of researchers that deal with microplastics monitoring all over the world. PMID:28060297

  18. Protocol for Microplastics Sampling on the Sea Surface and Sample Analysis.

    PubMed

    Kovač Viršek, Manca; Palatinus, Andreja; Koren, Špela; Peterlin, Monika; Horvat, Petra; Kržan, Andrej

    2016-12-16

    Microplastic pollution in the marine environment is a scientific topic that has received increasing attention over the last decade. The majority of scientific publications address microplastic pollution of the sea surface. The protocol below describes the methodology for sampling, sample preparation, separation and chemical identification of microplastic particles. A manta net fixed on an »A frame« attached to the side of the vessel was used for sampling. Microplastic particles caught in the cod end of the net were separated from samples by visual identification and use of stereomicroscopes. Particles were analyzed for their size using an image analysis program and for their chemical structure using ATR-FTIR and micro FTIR spectroscopy. The described protocol is in line with recommendations for microplastics monitoring published by the Marine Strategy Framework Directive (MSFD) Technical Subgroup on Marine Litter. This written protocol with video guide will support the work of researchers that deal with microplastics monitoring all over the world.

  19. I-MAC: an incorporation MAC for wireless sensor networks

    NASA Astrophysics Data System (ADS)

    Zhao, Jumin; Li, Yikun; Li, Dengao; Lin, Xiaojie

    2017-11-01

    This paper proposes an innovative MAC protocol called I-MAC. Protocol for wireless sensor networks, which combines the advantages of collision tolerance and collision cancellation. The protocol increases the number of antenna in wireless sensor nodes. The purpose is to monitor the occurrence of packet collisions by increasing the number of antenna in real time. The built-in identity structure is used in the frame structure in order to help the sending node to identify the location of the receiving node after a data packet collision is detected. Packets can be recovered from where the conflict occurred. In this way, we can monitor the conflict for a fixed period of time. It can improve the channel utilisation through changing the transmission probability of collision nodes and solve the problem of hidden terminal through collision feedback mechanism. We have evaluated our protocol. Our results show that the throughput of I-MAC is 5 percentage points higher than that of carrier sense multiple access/collision notification. The network utilisation of I-MAC is more than 92%.

  20. (31)P cardiac magnetic resonance spectroscopy during leg exercise at 3 Tesla.

    PubMed

    Hudsmith, Lucy E; Tyler, Damian J; Emmanuel, Yaso; Petersen, Steffen E; Francis, Jane M; Watkins, Hugh; Clarke, Kieran; Robson, Matthew D; Neubauer, Stefan

    2009-12-01

    Investigation of phosphorus ((31)P) magnetic resonance spectroscopy under stress conditions provides a non-invasive tool to examine alterations in cardiac high-energy phosphate metabolism that may not be evident at rest. Our aim was to establish cardiac (31)P MR spectroscopy during leg exercise at 3T. The increased field strength should provide a higher signal to noise ratio than at lower field strengths. Furthermore, relatively high temporal resolution at a sufficiently fine spatial resolution should be feasible. (31)P MR spectra were obtained with a 3D acquisition weighted chemical shift imaging sequence in 20 healthy volunteers at rest, during dynamic physiological leg exercise and after recovery at 3T. Haemodynamic measurements were made throughout and the rate pressure product calculated. With exercise, the mean heart rate increased by 73%, achieving a mean increase in rate pressure product of 115%. The corrected PCr/ATP ratio for subjects at rest was 2.02 +/- 0.43, exercise 2.14 +/- 0.67 (P = 0.54 vs. rest) and at recovery 2.03 +/- 0.52 (P = 0.91 vs. rest, P = 0.62 vs. exercise). A cardiac (31)P MR spectroscopy physiological exercise-recovery protocol is feasible at 3T. There was no significant change in high-energy cardiac phosphate metabolite concentrations in healthy volunteers at rest, during physiological leg exercise or during recovery. When applied to patients with heart disease, this protocol should provide insights into physiological and pathological cardiac metabolism.

  1. Prebreathe Protocol for Extravehicular Activity Technical Consultation Report

    NASA Technical Reports Server (NTRS)

    Ross, Jerry; Duncan, Michael

    2008-01-01

    In the performance of EVA by that National Aeronautics and Space Administration (NASA) astronauts, there exists a risk of DCS as the suit pressure is reduced to 4.3 pounds per square inch, absolute (psia) from the International Space Station (ISS) pressure of 14.7 psia. Several DCS-preventive procedures have been developed and implemented. Each of these procedures involve the use of oxygen (O2) prebreathe to effectively washout tissue nitrogen (N2).The management of the ISS Programs convened an expert independent peer review Team to conduct a review of the Decompression Sickness (DCS) risks associated with the Extra Vehicular Activity (EVA) Campout Prebreathe (PB) protocol for its consideration for use on future missions. The major findings and recommendations of the expert panel are: There is no direct experimental data to confirm the potential DCS risks of the Campout PB protocol. However, based on model data, statistical probability, physiology, and information derived from similar PB protocols, there is no compelling evidence to suggest that the Campout PB protocol is less safe than the other NASA approved PB protocols.

  2. The exploitation of inflammation in photodynamic therapy of pleural cancer (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Davis, Richard W.; Miller, Joann; Houser, Cassandra L.; Klampatsa, Astero; Jenkins, Tim; Cengel, Keith A.; Albelda, Steven M.; Busch, Theresa M.

    2017-02-01

    The onset of inflammation is a well-known physiology in tumors treated with photodynamic therapy (PDT). After PDT, the release of danger signals causes an influx of neutrophils, activation of dendritic cells, and an eventual initiation of the adaptive immune response. However, inflammation also lies at a crucial fulcrum for treatment outcome, as it can stimulate the expression of resistance factors. Therefore, effective treatment with PDT requires an understanding of the holistic contribution of inflammation. Within, we outline two means of studying tumor inflammation in the setting of PDT. Experiments are conducted in murine models of mesothelioma, including those that incorporate surgery prior to PDT or pleural propagation of the disease. First, we use a chemiluminescent agent, luminol, to detect the influx of neutrophils by in vivo molecular imaging. This longitudinal approach allows for the repeated non-invasive monitoring of PDT-induced neutrophil influx. Data clearly identify protocol-specific differences in tumor-associated neutrophil activity. Second, we describe the application of cone-beam CT to detect the fibrosis associated with murine orthotropic mesothelioma models. This approach incorporates novel methods in image segmentation to accurately identify diffuse disease in the thoracic cavity. These studies lay the foundation for future research to correlate long-term response with local PDT-induced inflammation. Such methods in monitoring of inflammation or tumor burden will enable characterization of the consequences of combinatorial therapy (e.g., intraoperative PDT). Resulting data will guide the selection of pharmacological agents or molecular imaging techniques that respectively exploit inflammation for therapeutic or monitoring purposes.

  3. Effect of venous stenting on intracranial pressure in idiopathic intracranial hypertension.

    PubMed

    Matloob, Samir A; Toma, Ahmed K; Thompson, Simon D; Gan, Chee L; Robertson, Fergus; Thorne, Lewis; Watkins, Laurence D

    2017-08-01

    Idiopathic intracranial hypertension (IIH) is characterised by an increased intracranial pressure (ICP) in the absence of any central nervous system disease or structural abnormality and by normal CSF composition. Management becomes complicated once surgical intervention is required. Venous sinus stenosis has been suggested as a possible aetiology for IIH. Venous sinus stenting has emerged as a possible interventional option. Evidence for venous sinus stenting is based on elimination of the venous pressure gradient and clinical response. There have been no studies demonstrating the immediate effect of venous stenting on ICP. Patients with a potential or already known diagnosis of IIH were investigated according to departmental protocol. ICP monitoring was performed for 24 h. When high pressures were confirmed, CT venogram and catheter venography were performed to look for venous stenosis to demonstrate a pressure gradient. If positive, venous stenting would be performed and ICP monitoring would continue for a further 24 h after deployment of the venous stent. Ten patients underwent venous sinus stenting with concomitant ICP monitoring. Nine out of ten patients displayed an immediate reduction in their ICP that was maintained at 24 h. The average reduction in mean ICP and pulsatility was significant (p = 0.003). Six out of ten patients reported a symptomatic improvement within the first 2 weeks. Venous sinus stenting results in an immediate reduction in ICP. This physiological response to venous stenting has not previously been reported. Venous stenting could offer an alternative treatment option in correctly selected patients with IIH.

  4. Acoustic monitoring of first responder's physiology for health and performance surveillance

    NASA Astrophysics Data System (ADS)

    Scanlon, Michael V.

    2002-08-01

    Acoustic sensors have been used to monitor firefighter and soldier physiology to assess health and performance. The Army Research Laboratory has developed a unique body-contacting acoustic sensor that can monitor the health and performance of firefighters and soldiers while they are doing their mission. A gel-coupled sensor has acoustic impedance properties similar to the skin that facilitate the transmission of body sounds into the sensor pad, yet significantly repel ambient airborne noises due to an impedance mismatch. This technology can monitor heartbeats, breaths, blood pressure, motion, voice, and other indicators that can provide vital feedback to the medics and unit commanders. Diverse physiological parameters can be continuously monitored with acoustic sensors and transmitted for remote surveillance of personnel status. Body-worn acoustic sensors located at the neck, breathing mask, and wrist do an excellent job at detecting heartbeats and activity. However, they have difficulty extracting physiology during rigorous exercise or movements due to the motion artifacts sensed. Rigorous activity often indicates that the person is healthy by virtue of being active, and injury often causes the subject to become less active or incapacitated making the detection of physiology easier. One important measure of performance, heart rate variability, is the measure of beat-to-beat timing fluctuations derived from the interval between two adjacent beats. The Lomb periodogram is optimized for non-uniformly sampled data, and can be applied to non-stationary acoustic heart rate features (such as 1st and 2nd heart sounds) to derive heart rate variability and help eliminate errors created by motion artifacts. Simple peak-detection above or below a certain threshold or waveform derivative parameters can produce the timing and amplitude features necessary for the Lomb periodogram and cross-correlation techniques. High-amplitude motion artifacts may contribute to a different frequency or baseline noise due to the timing differences between the noise artifacts and heartbeat features. Data from a firefighter experiment is presented.

  5. The physiology of ex vitro pineapple (Ananas comosus L. Merr. var MD-2) as CAM or C3 is regulated by the environmental conditions.

    PubMed

    Aragón, C; Carvalho, L; González, J; Escalona, M; Amancio, S

    2012-04-01

    Many plant species grown under in vitro controlled conditions can be used as models for the study of physiological processes. Adult pineapple can display CAM physiology while in vitro it functions as a C3 plant. Ex vitro Ananas comosus has plastic morphology and physiology, both easy to modify from C3 to CAM by changing the environmental conditions. The yield of survival for a rentable propagation protocol of pineapple is closely related with the C3/CAM shift and the associated physiological characteristics. In the present work, ex vitro pineapple plants were divided in two sets and subjected to C3 and CAM-inducing environmental conditions, determined by light intensity and relative humidity, respectively, 40 μmol m(-2) s(-1)/85% and 260 μmol m(-2) s(-1)/50%. The results demonstrated that the stress imposed by the environmental conditions switched pineapple plants from C3 to CAM behavior. Comparing to CAM induced, C3-induced pineapple plants showed substandard growth parameters and morphological leaf characteristics but a better rooting process and a higher ABA production, a phenotype closer to adult plants, which are expected to produce fruits in a normal production cycle. We conclude that the upholding of these characteristics is conditioned by low light intensity plus high relative humidity, especially during the first 8 weeks of ex vitro growth. It is expected that the better understanding of pineapple acclimatization will contribute to the design of a protocol to apply as a rentable tool in the pineapple agronomic industry. © Springer-Verlag 2011

  6. Establishing treatment protocols for clinical mastitis.

    PubMed

    Roberson, Jerry R

    2003-03-01

    Each farm has a unique mix of mastitis pathogens and management procedures that have evolved over time. The herd veterinarian should work with the manager/owner to systematically develop treatment protocols that meet the needs and management of the farm. To establish a mastitis treatment protocol, it is necessary to develop a system to routinely identify clinical mastitis cases, develop a herd-specific severity level assessment system, manage the clinical mastitis cases based on severity level and culture result (when available), avoid antibiotic residues, and monitor the success of the system and alter the protocol as necessary.

  7. The Circadian System Contributes to Apnea Lengthening across the Night in Obstructive Sleep Apnea.

    PubMed

    Butler, Matthew P; Smales, Carolina; Wu, Huijuan; Hussain, Mohammad V; Mohamed, Yusef A; Morimoto, Miki; Shea, Steven A

    2015-11-01

    To test the hypothesis that respiratory event duration exhibits an endogenous circadian rhythm. Within-subject and between-subjects. Inpatient intensive physiologic monitoring unit at the Brigham and Women's Hospital. Seven subjects with moderate/severe sleep apnea and four controls, age 48 (SD = 12) years, 7 males. Subjects completed a 5-day inpatient protocol in dim light. Polysomnography was recorded during an initial control 8-h night scheduled at the usual sleep time, then through 10 recurrent cycles of 2 h 40 min sleep and 2 h 40 min wake evenly distributed across all circadian phases, and finally during another 8-h control sleep period. Event durations, desaturations, and apnea-hypopnea index for each sleep opportunity were assessed according to circadian phase (derived from salivary melatonin), time into sleep, and sleep stage. Average respiratory event durations in NREM sleep significantly lengthened across both control nights (21.9 to 28.2 sec and 23.7 to 30.2 sec, respectively). During the circadian protocol, event duration in NREM increased across the circadian phases that corresponded to the usual sleep period, accounting for > 50% of the increase across normal 8-h control nights. AHI and desaturations were also rhythmic: AHI was highest in the biological day while desaturations were greatest in the biological night. The endogenous circadian system plays an important role in the prolongation of respiratory events across the night, and might provide a novel therapeutic target for modulating sleep apnea. © 2015 Associated Professional Sleep Societies, LLC.

  8. Lunar Health Monitor (LHM)

    NASA Technical Reports Server (NTRS)

    Lisy, Frederick J.

    2015-01-01

    Orbital Research, Inc., has developed a low-profile, wearable sensor suite for monitoring astronaut health in both intravehicular and extravehicular activities. The Lunar Health Monitor measures respiration, body temperature, electrocardiogram (EKG) heart rate, and other cardiac functions. Orbital Research's dry recording electrode is central to the innovation and can be incorporated into garments, eliminating the need for conductive pastes, adhesives, or gels. The patented dry recording electrode has been approved by the U.S. Food and Drug Administration. The LHM is easily worn under flight gear or with civilian clothing, making the system completely versatile for applications where continuous physiological monitoring is needed. During Phase II, Orbital Research developed a second-generation LHM that allows sensor customization for specific monitoring applications and anatomical constraints. Evaluations included graded exercise tests, lunar mission task simulations, functional battery tests, and resting measures. The LHM represents the successful integration of sensors into a wearable platform to capture long-duration and ambulatory physiological markers.

  9. Monitoring of brain oxygen saturation (INVOS) in a protocol to direct blood transfusions during cardiac surgery: a prospective randomized clinical trial.

    PubMed

    Vretzakis, George; Georgopoulou, Stavroula; Stamoulis, Konstantinos; Tassoudis, Vassilios; Mikroulis, Dimitrios; Giannoukas, Athanasios; Tsilimingas, Nikolaos; Karanikolas, Menelaos

    2013-06-07

    Blood transfusions are common in cardiac surgery, but have been associated with increased morbidity and long-term mortality. Efforts to reduce blood product use during cardiac surgery include fluid restriction to minimize hemodilution, and protocols to guide transfusion decisions. INVOS is a modality that monitors brain tissue oxygen saturation, and could be useful in guiding decisions to transfuse. However, the role of INVOS (brain tissue oxygen saturation) as part of an algorithm to direct blood transfusions during cardiac surgery has not been evaluated. This study was conducted to investigate the value of INVOS as part of a protocol for blood transfusions during cardiac surgery. Prospective, randomized, blinded clinical trial, on 150 (75 per group) elective cardiac surgery patients. The study was approved by the Institution Ethics committee and all patients gave written informed consent. Data were initially analyzed based on "intention to treat", but subsequently were also analyzed "per protocol". When protocol was strictly followed ("per protocol analysis"), compared to the control group, significantly fewer patients monitored with INVOS received any blood transfusions (46 of 70 patients in INVOS group vs. 55 of 67 patients in the control group, p = 0.029). Similarly, patients monitored with INVOS received significantly fewer units of red blood cell transfusions intraoperatively (0.20 ± 0.50 vs. 0.52 ± 0.88, p = 0.008) and overall during hospital stay (1.31 ± 1.20 vs. 1.82 ± 1.46, p = 0.024). When data from all patients (including patient with protocol violation) were analyzed together ("intention to treat analysis"), the observed reduction of blood transfusions in the INVOS group was still significant (51 of 75 patients transfused in the INVOS group vs. 63 of 75 patients transfused in the control group, p = 0.021), but the overall number of units transfused per patient did not differ significantly between the groups (1.55 ± 1.97 vs. 1.84 ± 1.41, p = 0.288). Our data suggest that INVOS could be a useful tool as part of an algorithm to guide decisions for blood transfusion in cardiac surgery. Additional data from rigorous, well designed studies are needed to further evaluate the role of INVOS in guiding blood transfusions in cardiac surgery, and circumvent the limitations of this study.

  10. Identifying Effective and Sustainable Measures for Community-Based Environmental Monitoring

    NASA Astrophysics Data System (ADS)

    McKay, Ariana J.; Johnson, Chris J.

    2017-09-01

    Resource development projects typically result in monitoring programs that fail to fully consider the values and participation of surrounding communities. Also, monitoring protocols for single environmental values can be insufficient for addressing the cumulative impacts of resource development. Community-based environmental monitoring (CBEM) has emerged as a way to meaningfully include local citizens in the decision-making process and assessment of the development of natural resources. Our research explored how to develop effective and sustainable CBEM. Interviews were conducted with staff from 15 CBEM programs established across Canada to identify criteria of what constitutes effective CBEM. Results demonstrate that CBEM offers an effective, locally adapted, and culturally applicable approach to facilitate community participation in natural resource management and to track environmental change. Benefits of CBEM include: locally relevant monitoring protocols, inclusion of cumulative impacts, better informed decision-making, and increased awareness and collaboration amongst community, governments, and proponents. Challenges associated with CBEM are cost, capacity, longevity, distribution of results, and establishing credibility. This research validates the use of CBEM for improving resource management.

  11. Sensing interstitial glucose to nudge active lifestyles (SIGNAL): feasibility of combining novel self-monitoring technologies for persuasive behaviour change.

    PubMed

    Whelan, Maxine E; Kingsnorth, Andrew P; Orme, Mark W; Sherar, Lauren B; Esliger, Dale W

    2017-10-08

    Increasing physical activity (PA) reduces the risk of developing diabetes, highlighting the role of preventive medicine approaches. Changing lifestyle behaviours is difficult and is often predicated on the assumption that individuals are willing to change their lifestyles today to reduce the risk of developing disease years or even decades later. The self-monitoring technologies tested in this study will present PA feedback in real time, parallel with acute physiological data. Presenting the immediate health benefits of being more physically active may help enact change by observing the immediate consequences of that behaviour. The present study aims to assess user engagement with the self-monitoring technologies in individuals at moderate-to-high risk of developing type 2 diabetes. 45 individuals with a moderate-to-high risk, aged ≥40 years old and using a compatible smartphone, will be invited to take part in a 7-week protocol. Following 1 week of baseline measurements, participants will be randomised into one of three groups: group 1- glucose feedback followed by biobehavioural feedback (glucose plus PA); group 2-PA feedback followed by biobehavioural feedback; group 3-biobehavioural feedback. A PA monitor and a flash glucose monitor will be deployed during the intervention. Participants will wear both devices throughout the intervention but blinded to feedback depending on group allocation. The primary outcome is the level of participant engagement and will be assessed by device use and smartphone usage. Feasibility will be assessed by the practicality of the technology and screening for diabetes risk. Semistructured interviews will be conducted to explore participant experiences using the technologies. ISRCTN17545949. Registered on 15/05/2017. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  12. Macroecology of Australian Tall Eucalypt Forests: Baseline Data from a Continental-Scale Permanent Plot Network

    PubMed Central

    Wood, Sam W.; Prior, Lynda D.; Stephens, Helen C.; Bowman, David M. J. S.

    2015-01-01

    Tracking the response of forest ecosystems to climate change demands large (≥1 ha) monitoring plots that are repeatedly measured over long time frames and arranged across macro-ecological gradients. Continental scale networks of permanent forest plots have identified links between climate and carbon fluxes by monitoring trends in tree growth, mortality and recruitment. The relationship between tree growth and climate in Australia has been recently articulated through analysis of data from smaller forest plots, but conclusions were limited by (a) absence of data on recruitment and mortality, (b) exclusion of non-eucalypt species, and (c) lack of knowledge of stand age or disturbance histories. To remedy these gaps we established the Ausplots Forest Monitoring Network: a continental scale network of 48 1 ha permanent plots in highly productive tall eucalypt forests in the mature growth stage. These plots are distributed across cool temperate, Mediterranean, subtropical and tropical climates (mean annual precipitation 850 to 1900 mm per year; mean annual temperature 6 to 21°C). Aboveground carbon stocks (AGC) in these forests are dominated by eucalypts (90% of AGC) whilst non-eucalypts in the understorey dominated species diversity and tree abundance (84% of species; 60% of stems). Aboveground carbon stocks were negatively related to mean annual temperature, with forests at the warm end of the temperature range storing approximately half the amount of carbon as forests at the cool end of the temperature range. This may reflect thermal constraints on tree growth detected through other plot networks and physiological studies. Through common protocols and careful sampling design, the Ausplots Forest Monitoring Network will facilitate the integration of tall eucalypt forests into established global forest monitoring initiatives. In the context of projections of rapidly warming and drying climates in Australia, this plot network will enable detection of links between climate and growth, mortality and carbon dynamics of eucalypt forests. PMID:26368919

  13. How to construct an optimal interim report: What the data monitoring committee does and doesn't need to know.

    PubMed

    Neaton, James D; Grund, Birgit; Wentworth, Deborah

    2018-03-01

    Data monitoring committees for randomized clinical trials have the responsibility of safeguarding interests of trial participants. To do so, the data monitoring committee must receive reports on safety and efficacy to assess risk/benefit and on trial conduct to ensure that the study can achieve its goals. This article outlines the key components of reports to the data monitoring committee and the important role of the unblinded statistician in preparing those reports. Most data monitoring committee meetings include open and closed sessions. For each session, there is a report of interim results. The open session is attended by the sponsor and lead investigators, including the statistician(s) responsible for the trial design. These investigators are blinded to the interim treatment comparisons. The closed session is attended by the data monitoring committee members and by the statistician(s) who prepared the closed report. These individuals are unblinded to interim treatment comparisons and therefore are not involved in study design changes. The optimal content of data monitoring committee reports and qualifications of the unblinded statistician(s) are discussed. Open reports should include responses to data monitoring committee recommendations, a synopsis of the protocol, a review of the protocol history and amendments, and information on enrollment, baseline characteristics, completeness of follow-up, and data quality. The open report is also a vehicle through which the sponsor and investigators should inform the data monitoring committee of relevant external information. Data in the open report are pooled over the treatment groups. The open report should not include data summaries by treatment group. The closed report should include a written summary with references to key tables and figures and methods used to prepare them. Tables and figures should summarize baseline characteristics, follow-up completeness, treatment adherence, and major safety and efficacy outcomes by treatment group. Text summaries should accompany the tables and figures. The data monitoring committee monitoring history (e.g. treatment differences at previous meetings) should be summarized. The unblinded statistician preparing the closed report should be familiar with the protocol and data collection plan and be capable of customizing the report to the current stage of the trial. This includes anticipating questions that may arise during the data monitoring committee review and pro-actively including data summaries to address these questions. There is considerable variation in the quality of open and closed data monitoring committee reports. Open and closed data monitoring committee reports should be concise, up to date, and informative. To achieve this, unblinded statisticians responsible for preparing closed data monitoring committee reports should be familiar with the statistical methods, the trial protocol, and the data collection plan. They should be capable of anticipating questions from the data monitoring committee and responding to requests for additional analyses.

  14. Novel Techniques for Retroperitoneal Implantation of Telemetry Transmitters for Physiologic Monitoring in Gottingen Minipigs (Sus scrofa domesticus)

    DTIC Science & Technology

    2014-12-01

    scrofa domesticus) Scott Willens,1,* David M Cox,3 Ernest H Braue,1 Todd M Myers,1 and Matthew D Wegner2 Telemetric monitoring of physiologic parameters...BMC Vet Res 4:51. 15. Hulet SW, Sommerville DR, Crosier RB, Dabisch PA, Miller DB, Benton BJ, Forster JS, Scotto JA, Jarvis JR , Krauthauser C...domestic white pig. Basic Clin Pharmacol Toxicol 97:35–38. 6. Crawshaw GJ, Mills KJ, Mosley C, Patterson BR. 2007. Field im- plantation of

  15. Human factors approach to evaluate the user interface of physiologic monitoring.

    PubMed

    Fidler, Richard; Bond, Raymond; Finlay, Dewar; Guldenring, Daniel; Gallagher, Anthony; Pelter, Michele; Drew, Barbara; Hu, Xiao

    2015-01-01

    As technology infiltrates more of our personal and professional lives, user expectations for intuitive design have driven many consumer products, while medical equipment continues to have high training requirements. Not much is known about the usability and user experience associated with hospital monitoring equipment. This pilot project aimed to better understand and describe the user interface interaction and user experience with physiologic monitoring technology. This was a prospective, descriptive, mixed-methods quality improvement project to analyze perceptions and task analyses of physiologic monitors. Following a survey of practice patterns and perceived abilities to accomplish key tasks, 10 voluntary experienced physician and nurse subjects were asked to perform a series of tasks in 7 domains of monitor operations on GE Monitoring equipment in a single institution. For each task analysis, data were collected on time to complete the task, the number of button pushes or clicks required to accomplish the task, economy of motion, and observed errors. Although 60% of the participants reported incorporating monitoring data into patient care, 80% of participants preferred to receive monitoring data at the point of care (bedside). Average perceived central station usability is 5.3 out of 10 (ten is easiest). High variability exists in monitoring station interaction performance among those participating in this project. Alarms were almost universally silenced without cognitive recognition of the alarm state. Education related to monitoring operations appeared largely absent in this sample. Most users perceived the interface to not be intuitive, complaining of multiple layers and steps for data retrieval. These clinicians report real-time monitoring helpful for abrupt changes in condition like arrhythmias; however, reviewing alarms is not prioritized as valuable due to frequent false alarms. Participants requested exporting monitoring data to electronic medical records. Much research is needed to develop best practices for display of real-time information, organization and filtering of meaningful data, and simplified ways to find information. Published by Elsevier Inc.

  16. STANDARDIZATION AND VALIDATION OF METHODS FOR ENUMERATION OF FECAL COLIFORM AND SALMONELLA IN BIOSOLIDS

    EPA Science Inventory

    Current federal regulations required monitoring for fecal coliforms or Salmonella in biosolids destined for land application. Methods used for analysis of fecal coliforms and Salmonella were reviewed and a standard protocol was developed. The protocols were then...

  17. STANDARDIZATION AND VALIDATION OF METHODS FOR ENUMERATION OF FECAL COLIFORM AND SALMONELLA IN BIOSOLIDS

    EPA Science Inventory

    Current federal regulations require monitoring for fecal coliforms or Salmonella in biosolids destined for land application. Methods used for analysis of fecal coliforms and Salmonella were reviewed and a standard protocol was developed. The protocols were then evaluated by testi...

  18. Establishment of integrated protocols for automated high throughput kinetic chlorophyll fluorescence analyses.

    PubMed

    Tschiersch, Henning; Junker, Astrid; Meyer, Rhonda C; Altmann, Thomas

    2017-01-01

    Automated plant phenotyping has been established as a powerful new tool in studying plant growth, development and response to various types of biotic or abiotic stressors. Respective facilities mainly apply non-invasive imaging based methods, which enable the continuous quantification of the dynamics of plant growth and physiology during developmental progression. However, especially for plants of larger size, integrative, automated and high throughput measurements of complex physiological parameters such as photosystem II efficiency determined through kinetic chlorophyll fluorescence analysis remain a challenge. We present the technical installations and the establishment of experimental procedures that allow the integrated high throughput imaging of all commonly determined PSII parameters for small and large plants using kinetic chlorophyll fluorescence imaging systems (FluorCam, PSI) integrated into automated phenotyping facilities (Scanalyzer, LemnaTec). Besides determination of the maximum PSII efficiency, we focused on implementation of high throughput amenable protocols recording PSII operating efficiency (Φ PSII ). Using the presented setup, this parameter is shown to be reproducibly measured in differently sized plants despite the corresponding variation in distance between plants and light source that caused small differences in incident light intensity. Values of Φ PSII obtained with the automated chlorophyll fluorescence imaging setup correlated very well with conventionally determined data using a spot-measuring chlorophyll fluorometer. The established high throughput operating protocols enable the screening of up to 1080 small and 184 large plants per hour, respectively. The application of the implemented high throughput protocols is demonstrated in screening experiments performed with large Arabidopsis and maize populations assessing natural variation in PSII efficiency. The incorporation of imaging systems suitable for kinetic chlorophyll fluorescence analysis leads to a substantial extension of the feature spectrum to be assessed in the presented high throughput automated plant phenotyping platforms, thus enabling the simultaneous assessment of plant architectural and biomass-related traits and their relations to physiological features such as PSII operating efficiency. The implemented high throughput protocols are applicable to a broad spectrum of model and crop plants of different sizes (up to 1.80 m height) and architectures. The deeper understanding of the relation of plant architecture, biomass formation and photosynthetic efficiency has a great potential with respect to crop and yield improvement strategies.

  19. What Do We Really Know About the Safety of Tai Chi?: A Systematic Review of Adverse Event Reports in Randomized Trials

    PubMed Central

    Wayne, Peter M.; Berkowitz, Danielle L.; Litrownik, Daniel E.; Buring, Julie E.; Yeh, Gloria Y.

    2014-01-01

    Objective Systematically review frequency and quality of adverse event (AE) reports in randomized clinical trials (RCTs) of Tai Chi (TC). Data Sources Electronic searches of PubMed/MEDLINE and additional databases from inception through March 2013 of English-language RCTs. Search terms were tai chi, taiji, tai chi chuan. Data were independently extracted by two investigators. Study Selection We included all available randomized controlled trials (RCTs) that were published in English and used Tai Chi as an intervention. Inclusion and exclusion of studies were reported in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. Data Extraction Eligible RCTs were categorized with respect to AE reporting: 1) No mention of protocols for monitoring AEs or reports of AEs; 2) Reports of AEs either with or without explicit protocols for monitoring AEs. Data Synthesis 153 eligible RCTs were identified, most targeting older adults. Only 50 eligible trials (33%) included reporting of AEs, and of these, only 18 trials (12% overall) also reported an explicit AE monitoring protocol. Protocols varied with respect to rigor of systematic monitoring in both Tai Chi and comparison groups. Reported AEs were typically minor and expected, and primarily musculoskeletal related (e.g., knee and back pain); no intervention-related serious AEs were reported. Conclusions Tai Chi is unlikely to result in serious adverse events, but may be associated with minor musculoskeletal aches and pains. However, poor and inconsistent reporting of AEs greatly limits the conclusions that can be drawn regarding the safety of Tai Chi. PMID:24878398

  20. Real-time in vivo uric acid biosensor system for biophysical monitoring of birds.

    PubMed

    Gumus, A; Lee, S; Karlsson, K; Gabrielson, R; Winkler, D W; Erickson, D

    2014-02-21

    Research on birds has long played an important role in ecological investigations, as birds are relatively easily observed, and their high metabolic rates and diurnal habits make them quite evidently responsive to changes in their environments. A mechanistic understanding of such avian responses requires a better understanding of how variation in physiological state conditions avian behavior and integrates the effects of recent environmental changes. There is a great need for sensor systems that will allow free-flying birds to interact with their environment and make unconstrained decisions about their spatial location at the same time that their physiological state is being monitored in real time. We have developed a miniature needle-based enzymatic sensor system suitable for continuous real-time amperometric monitoring of uric acid levels in unconstrained live birds. The sensor system was constructed with Pt/Ir wire and Ag/AgCl paste. Uricase enzyme was immobilized on a 0.7 mm sensing cavity of Nafion/cellulose inner membrane to minimize the influences of background interferents. The sensor response was linear from 0.05 to 0.6 mM uric acid, which spans the normal physiological range for most avian species. We developed a two-electrode potentiostat system that drives the biosensor, reads the output current, and wirelessly transmits the data. In addition to extensive characterization of the sensor and system, we also demonstrate autonomous operation of the system by collecting in vivo extracellular uric acid measurements on a domestic chicken. The results confirm our needle-type sensor system's potential for real-time monitoring of birds' physiological state. Successful application of the sensor in migratory birds could open up a new era of studying both the physiological preparation for migration and the consequences of sustained avian flight.

  1. Exercise-training protocols for astronauts in microgravity

    NASA Technical Reports Server (NTRS)

    Greenleaf, J. E.; Bulbulian, R.; Bernauer, E. M.; Haskell, W. L.; Moore, T.

    1989-01-01

    Based on physical working requirements for astronauts during intra- and extravehicular activity and on the findings from bed-rest studies that utilized exercise training as a countermeasure for the reduction of aerobic power, deterioration of muscular strength and endurance, decrements in mood and cognitive performance, and possibly for bone loss, two exercise protocols are proposed. One assumes that, during microgravity, astronaut exercise physiological functions should be maintained at 100 percent of ground-based levels. The other assumes that maximal aerobic power in flight can be reduced by 10 percent of the ground-based level.

  2. A watershed-scale monitoring protocol for bull trout

    Treesearch

    Dan Isaak; Bruce Rieman; Dona Horan

    2009-01-01

    Bull trout is a threatened species native to the Pacific Northwest that has been selected as Management Indicator Species on several national forests. Scientifically defensible procedures for monitoring bull trout populations are necessary that can be applied to the extensive and remote lands managed by the U.S. Forest Service. Distributional monitoring focuses...

  3. Noninvasive and cost-effective trapping method for monitoring sensitive mammal populations

    Treesearch

    Stephanie E. Trapp; Elizabeth A. Flaherty

    2017-01-01

    Noninvasive sampling methods provide a means to monitor endangered, threatened, or sensitive species or populations while increasing the efficacy of personnel effort and time. We developed a monitoring protocol that utilizes single-capture hair snares and analysis of morphological features of hair for evaluating populations. During 2015, we used the West Virginia...

  4. Keeping Scores: Audited Self-Monitoring of High-Stakes Testing Environments

    ERIC Educational Resources Information Center

    Padilla, Raymond; Richards, Michael

    2006-01-01

    To address a public relations problem faced by a large urban public school district in Texas, we conducted action research that resulted in an audited self-monitoring system for high-stakes testing environments. The system monitors violations of testing protocols while identifying and disseminating best practices to improve the education of…

  5. Bioaccessibility of As, Cd, Cu, Ni, Pb, and Sb in toys and low-cost jewelry.

    PubMed

    Guney, Mert; Zagury, Gerald J

    2014-01-21

    Children can be exposed to toxic elements in toys and jewelry following ingestion. As, Cd, Cu, Ni, Pb, and Sb bioavailability was assessed (n = 24) via the in vitro gastrointestinal protocol (IVG), the physiologically based extraction test (PBET), and the European Toy Safety Standard protocol (EN 71-3), and health risks were characterized. Cd, Cu, Ni, and Pb were mobilized from 19 metallic toys and jewelry (MJ) and one crayon set. Bioaccessible Cd, Ni, or Pb exceeded EU migratable concentration limits in four to six MJ, depending on the protocol. Using two-phase (gastric + intestinal) IVG or PBET might be preferable over EN 71-3 since they better represent gastrointestinal physiology. Bioaccessible and total metal concentrations were different and not always correlated, indicating that bioaccessibility measurement may provide more accurate risk characterization. More information on impacts of multiple factors affecting metals mobilization from toys and jewelry is needed before recommending specific tests. Hazard index (HI) for Cd, Ni, or Pb were >1 for all six MJ exceeding the EU limits. For infants (6-12 mo old), 10 MJ had HI > 1 for Cd, Cu, Ni, or Pb (up to 75 for Cd and 43 for Pb). Research on prolonged exposure to MJ and comprehensive risk characterization for toys and jewelry exposure is recommended.

  6. E-SAP: Efficient-Strong Authentication Protocol for Healthcare Applications Using Wireless Medical Sensor Networks

    PubMed Central

    Kumar, Pardeep; Lee, Sang-Gon; Lee, Hoon-Jae

    2012-01-01

    A wireless medical sensor network (WMSN) can sense humans’ physiological signs without sacrificing patient comfort and transmit patient vital signs to health professionals’ hand-held devices. The patient physiological data are highly sensitive and WMSNs are extremely vulnerable to many attacks. Therefore, it must be ensured that patients’ medical signs are not exposed to unauthorized users. Consequently, strong user authentication is the main concern for the success and large scale deployment of WMSNs. In this regard, this paper presents an efficient, strong authentication protocol, named E-SAP, for healthcare application using WMSNs. The proposed E-SAP includes: (1) a two-factor (i.e., password and smartcard) professional authentication; (2) mutual authentication between the professional and the medical sensor; (3) symmetric encryption/decryption for providing message confidentiality; (4) establishment of a secure session key at the end of authentication; and (5) professionals can change their password. Further, the proposed protocol requires three message exchanges between the professional, medical sensor node and gateway node, and achieves efficiency (i.e., low computation and communication cost). Through the formal analysis, security analysis and performance analysis, we demonstrate that E-SAP is more secure against many practical attacks, and allows a tradeoff between the security and the performance cost for healthcare application using WMSNs. PMID:22438729

  7. Design of Secure ECG-Based Biometric Authentication in Body Area Sensor Networks

    PubMed Central

    Peter, Steffen; Pratap Reddy, Bhanu; Momtaz, Farshad; Givargis, Tony

    2016-01-01

    Body area sensor networks (BANs) utilize wireless communicating sensor nodes attached to a human body for convenience, safety, and health applications. Physiological characteristics of the body, such as the heart rate or Electrocardiogram (ECG) signals, are promising means to simplify the setup process and to improve security of BANs. This paper describes the design and implementation steps required to realize an ECG-based authentication protocol to identify sensor nodes attached to the same human body. Therefore, the first part of the paper addresses the design of a body-area sensor system, including the hardware setup, analogue and digital signal processing, and required ECG feature detection techniques. A model-based design flow is applied, and strengths and limitations of each design step are discussed. Real-world measured data originating from the implemented sensor system are then used to set up and parametrize a novel physiological authentication protocol for BANs. The authentication protocol utilizes statistical properties of expected and detected deviations to limit the number of false positive and false negative authentication attempts. The result of the described holistic design effort is the first practical implementation of biometric authentication in BANs that reflects timing and data uncertainties in the physical and cyber parts of the system. PMID:27110785

  8. E-SAP: efficient-strong authentication protocol for healthcare applications using wireless medical sensor networks.

    PubMed

    Kumar, Pardeep; Lee, Sang-Gon; Lee, Hoon-Jae

    2012-01-01

    A wireless medical sensor network (WMSN) can sense humans' physiological signs without sacrificing patient comfort and transmit patient vital signs to health professionals' hand-held devices. The patient physiological data are highly sensitive and WMSNs are extremely vulnerable to many attacks. Therefore, it must be ensured that patients' medical signs are not exposed to unauthorized users. Consequently, strong user authentication is the main concern for the success and large scale deployment of WMSNs. In this regard, this paper presents an efficient, strong authentication protocol, named E-SAP, for healthcare application using WMSNs. The proposed E-SAP includes: (1) a two-factor (i.e., password and smartcard) professional authentication; (2) mutual authentication between the professional and the medical sensor; (3) symmetric encryption/decryption for providing message confidentiality; (4) establishment of a secure session key at the end of authentication; and (5) professionals can change their password. Further, the proposed protocol requires three message exchanges between the professional, medical sensor node and gateway node, and achieves efficiency (i.e., low computation and communication cost). Through the formal analysis, security analysis and performance analysis, we demonstrate that E-SAP is more secure against many practical attacks, and allows a tradeoff between the security and the performance cost for healthcare application using WMSNs.

  9. Design of Secure ECG-Based Biometric Authentication in Body Area Sensor Networks.

    PubMed

    Peter, Steffen; Reddy, Bhanu Pratap; Momtaz, Farshad; Givargis, Tony

    2016-04-22

    Body area sensor networks (BANs) utilize wireless communicating sensor nodes attached to a human body for convenience, safety, and health applications. Physiological characteristics of the body, such as the heart rate or Electrocardiogram (ECG) signals, are promising means to simplify the setup process and to improve security of BANs. This paper describes the design and implementation steps required to realize an ECG-based authentication protocol to identify sensor nodes attached to the same human body. Therefore, the first part of the paper addresses the design of a body-area sensor system, including the hardware setup, analogue and digital signal processing, and required ECG feature detection techniques. A model-based design flow is applied, and strengths and limitations of each design step are discussed. Real-world measured data originating from the implemented sensor system are then used to set up and parametrize a novel physiological authentication protocol for BANs. The authentication protocol utilizes statistical properties of expected and detected deviations to limit the number of false positive and false negative authentication attempts. The result of the described holistic design effort is the first practical implementation of biometric authentication in BANs that reflects timing and data uncertainties in the physical and cyber parts of the system.

  10. Sample size allocation for food item radiation monitoring and safety inspection.

    PubMed

    Seto, Mayumi; Uriu, Koichiro

    2015-03-01

    The objective of this study is to identify a procedure for determining sample size allocation for food radiation inspections of more than one food item to minimize the potential risk to consumers of internal radiation exposure. We consider a simplified case of food radiation monitoring and safety inspection in which a risk manager is required to monitor two food items, milk and spinach, in a contaminated area. Three protocols for food radiation monitoring with different sample size allocations were assessed by simulating random sampling and inspections of milk and spinach in a conceptual monitoring site. Distributions of (131)I and radiocesium concentrations were determined in reference to (131)I and radiocesium concentrations detected in Fukushima prefecture, Japan, for March and April 2011. The results of the simulations suggested that a protocol that allocates sample size to milk and spinach based on the estimation of (131)I and radiocesium concentrations using the apparent decay rate constants sequentially calculated from past monitoring data can most effectively minimize the potential risks of internal radiation exposure. © 2014 Society for Risk Analysis.

  11. Effects of Fatigue on Throwing Performance in Experienced Team Handball Players

    PubMed Central

    Nuño, Alberto; van den Tillaar, Roland; Guisado, Rafael; Martín, Ignacio; Martinez, Isidoro; Chirosa, Luis J.

    2016-01-01

    Abstract The purpose of this study was to investigate the effect of central and peripheral physiological fatigue on throwing accuracy and ball release velocity in team handball. Twenty male subjects (age 24.7 ± 3.9 yrs, body mass 88.5 ± 5.0 kg, body height 1.86 ± 0.05 m, training experience 12.7 ± 3.8 yrs) from one handball team participated in this study. The participants completed four sets of eight laps of a circuit that consisted of specific team handball drills/exercises, with decreasing recovery times between the laps in each set in order to induce physiological fatigue. Duration of the recovery intervals determined the description of the effort made in each set: “light" (80 s recovery between laps), “moderate" (40 s), “hard" (20 s) and “very hard" (10 s). A heart rate, concentration of lactate in blood and the rate of perceived exertion (RPE) were recorded. Ball velocity and accuracy were measured after each set and they both decreased during a fatigue protocol. However, accuracy only decreased significantly in the end of the protocol, while ball release was already affected after the first round of the protocol. The results substantiate the initial hypothesis and confirm that both throwing accuracy and ball release velocity decrease significantly as physiological fatigue increases. These variables began to decrease when the fatigue quantification values were high or very high. The findings can be used by coaches to develop training programs to teach players how to identify fatigue thresholds and combat the effects of fatigue through decision-making skills at critical game moments. PMID:28031762

  12. Validation protocols for blood pressure-measuring devices: status quo and development needs.

    PubMed

    Beime, Beate; Deutsch, Cornelia; Gomez, Timothy; Zwingers, Thomas; Mengden, Thomas; Bramlage, Peter

    2016-02-01

    Hypertension is a major risk factor for cardiovascular morbidity and mortality. Therefore, blood pressure self-measuring devices have emerged as valuable tools in patient care and the accuracy of these instruments is of fundamental importance. For this reason, several validation procedures for assessing the efficacy of blood pressure monitoring devices have been developed, including protocols by the Association for the Advancement of Medical Instrumentation, the British Hypertension Society, the German Hypertension League (Prüfsiegelprotokoll), and the International Protocol of the Working Group on Blood Pressure Monitoring of the European Society of Hypertension. In the past, most of the protocols have been reviewed and modified because of experiences gained during the validation studies carried out. However, each shows distinct differences, that is number and characteristics of patients required, blood pressure ranges, and the length of the validation procedure, which may result in unique advantages and/or limitations associated with their use. The continued standardization and evolution of these guidelines is essential to ensure the efficacy of blood pressure-measuring devices marketed for clinical and home use. Here, we aimed to compare four currently used validation protocols and to initiate a discussion on potential future improvements.

  13. On the use of wearable physiological monitors to assess heat strain during occupational heat stress.

    PubMed

    Notley, Sean R; Flouris, Andreas D; Kenny, Glen P

    2018-05-04

    Workers in many industries are required to perform arduous work in high heat stress conditions, which can lead to rapid increases in body temperature that elevate the risk of heat-related illness or even death. Traditionally, effort to mitigate work-related heat injury has been directed to the assessment of environmental heat stress (e.g., wet-bulb globe temperature), rather than the associated physiological strain responses (e.g., heart rate, skin and core temperatures). However, since a workers physiological response to a given heat stress is modified independently by inter-individual factors (e.g., age, sex, chronic disease, others) and intra-individual factors both within (e.g., medication use, fitness, acclimation and hydration state, others) and beyond a workers control (e.g., shift duration, illness, others), it becomes challenging to protect workers on an individual basis from heat-related injury without assessing those physiological responses. Recent advancements in wearable technology have made it possible to monitor one or more physiological indices of heat strain. Nonetheless, information on the utility of the wearable systems available for assessing occupational heat strain is unavailable. This communication is therefore directed at identifying the physiological indices of heat strain that may be quantified in the workplace and evaluating the wearable monitoring systems available for assessing those responses. Finally, emphasis is directed to the barriers associated with implementing these devices to assist in mitigating work-related heat injury. This information is fundamental for protecting worker health and could also be utilized to prevent heat illnesses in vulnerable people during leisure or athletic activities in the heat.

  14. Tissue viability monitoring: a multi-sensor wearable platform approach

    NASA Astrophysics Data System (ADS)

    Mathur, Neha; Davidson, Alan; Buis, Arjan; Glesk, Ivan

    2016-12-01

    Health services worldwide are seeking ways to improve patient care for amputees suffering from diabetes, and at the same time reduce costs. The monitoring of residual limb temperature, interface pressure and gait can be a useful indicator of tissue viability in lower limb amputees especially to predict the occurrence of pressure ulcers. This is further exacerbated by elevated temperatures and humid micro environment within the prosthesis which encourages the growth of bacteria and skin breakdown. Wearable systems for prosthetic users have to be designed such that the sensors are minimally obtrusive and reliable enough to faithfully record movement and physiological signals. A mobile sensor platform has been developed for use with the lower limb prosthetic users. This system uses an Arduino board that includes sensors for temperature, gait, orientation and pressure measurements. The platform transmits sensor data to a central health authority database server infrastructure through the Bluetooth protocol at a suitable sampling rate. The data-sets recorded using these systems are then processed using machine learning algorithms to extract clinically relevant information from the data. Where a sensor threshold is reached a warning signal can be sent wirelessly together with the relevant data to the patient and appropriate medical personnel. This knowledge is also useful in establishing biomarkers related to a possible deterioration in a patient's health or for assessing the impact of clinical interventions.

  15. Changes in ST, QT and RR ECG intervals during acute stress in firefighters: a pilot study.

    PubMed

    Paiva, Joana S; Rodrigues, Susana; Cunha, Joao Paulo Silva

    2016-08-01

    Firefighting is a stressful occupation. The monitoring of psychophysiological measures in those professionals can be a way to prevent and early detect cardiac diseases and other stress-related problems. The current study aimed to assess morphological changes in the ECG signal induced by acute stress. A laboratory protocol was conducted among 6 firefighters, including a laboratory stress-inducer task - the Trier Social Stress Task (TSST) - and a 2-choice reaction time task (CRTT) that was performed before (CRTT1) and after (CRTT2) the stress condition. ECG signals were continuously acquired using the VitalJacket®, a wearable t-shirt that acts as a medical certified ECG monitor. Results showed that ECG morphological features such as QT and ST intervals are able to differentiate stressful from non stressful events in first responders. Group mean Visual Analogue Scale (VAS) for stress assessment significantly increased after the stress task (TSST), relatively to the end of CRTT2 (after TSST: 4.67±1.63; after CRTT2: 3.17±0.75), a change that was accompanied by a significant increase in group mean QT and ST segments corrected for heart rate during TSST. These encouraging results will be followed by larger studies in order to explore those measures and its physiological impact under realistic environments in a higher scalability.

  16. Continuous wireless pressure monitoring and mapping with ultra-small passive sensors for health monitoring and critical care

    NASA Astrophysics Data System (ADS)

    Chen, Lisa Y.; Tee, Benjamin C.-K.; Chortos, Alex L.; Schwartz, Gregor; Tse, Victor; J. Lipomi, Darren; Wong, H.-S. Philip; McConnell, Michael V.; Bao, Zhenan

    2014-10-01

    Continuous monitoring of internal physiological parameters is essential for critical care patients, but currently can only be practically achieved via tethered solutions. Here we report a wireless, real-time pressure monitoring system with passive, flexible, millimetre-scale sensors, scaled down to unprecedented dimensions of 1 × 1 × 0.1 cubic millimeters. This level of dimensional scaling is enabled by novel sensor design and detection schemes, which overcome the operating frequency limits of traditional strategies and exhibit insensitivity to lossy tissue environments. We demonstrate the use of this system to capture human pulse waveforms wirelessly in real time as well as to monitor in vivo intracranial pressure continuously in proof-of-concept mice studies using sensors down to 2.5 × 2.5 × 0.1 cubic millimeters. We further introduce printable wireless sensor arrays and show their use in real-time spatial pressure mapping. Looking forward, this technology has broader applications in continuous wireless monitoring of multiple physiological parameters for biomedical research and patient care.

  17. Continuous wireless pressure monitoring and mapping with ultra-small passive sensors for health monitoring and critical care.

    PubMed

    Chen, Lisa Y; Tee, Benjamin C-K; Chortos, Alex L; Schwartz, Gregor; Tse, Victor; Lipomi, Darren J; Wong, H-S Philip; McConnell, Michael V; Bao, Zhenan

    2014-10-06

    Continuous monitoring of internal physiological parameters is essential for critical care patients, but currently can only be practically achieved via tethered solutions. Here we report a wireless, real-time pressure monitoring system with passive, flexible, millimetre-scale sensors, scaled down to unprecedented dimensions of 1 × 1 × 0.1 cubic millimeters. This level of dimensional scaling is enabled by novel sensor design and detection schemes, which overcome the operating frequency limits of traditional strategies and exhibit insensitivity to lossy tissue environments. We demonstrate the use of this system to capture human pulse waveforms wirelessly in real time as well as to monitor in vivo intracranial pressure continuously in proof-of-concept mice studies using sensors down to 2.5 × 2.5 × 0.1 cubic millimeters. We further introduce printable wireless sensor arrays and show their use in real-time spatial pressure mapping. Looking forward, this technology has broader applications in continuous wireless monitoring of multiple physiological parameters for biomedical research and patient care.

  18. A survey on signals and systems in ambulatory blood pressure monitoring using pulse transit time.

    PubMed

    Buxi, Dilpreet; Redouté, Jean-Michel; Yuce, Mehmet Rasit

    2015-03-01

    Blood pressure monitoring based on pulse transit or arrival time has been the focus of much research in order to design ambulatory blood pressure monitors. The accuracy of these monitors is limited by several challenges, such as acquisition and processing of physiological signals as well as changes in vascular tone and the pre-ejection period. In this work, a literature survey covering recent developments is presented in order to identify gaps in the literature. The findings of the literature are classified according to three aspects. These are the calibration of pulse transit/arrival times to blood pressure, acquisition and processing of physiological signals and finally, the design of fully integrated blood pressure measurement systems. Alternative technologies as well as locations for the measurement of the pulse wave signal should be investigated in order to improve the accuracy during calibration. Furthermore, the integration and validation of monitoring systems needs to be improved in current ambulatory blood pressure monitors.

  19. Molecular imaging of photodynamic therapy

    NASA Astrophysics Data System (ADS)

    Chang, Sung K.; Errabelli, Divya; Rizvi, Imran; Solban, Nicolas; O'Riordan, Katherine; Hasan, Tayyaba

    2006-02-01

    Recent advances in light sources, detectors and other optical imaging technologies coupled with the development of novel optical contrast agents have enabled real-time, high resolution, in vivo monitoring of molecular targets. Noninvasive monitoring of molecular targets is particularly relevant to photodynamic therapy (PDT), including the delivery of photosensitizer in the treatment site and monitoring of molecular and physiological changes following treatment. Our lab has developed optical imaging technologies to investigate these various aspects of photodynamic therapy (PDT). We used a laser scanning confocal microscope to monitor the pharmacokinetics of various photosensitizers in in vitro as well as ex vivo samples, and developed an intravital fluorescence microscope to monitor photosensitizer delivery in vivo in small animals. A molecular specific contrast agent that targets the vascular endothelial growth factor (VEGF) was developed to monitor the changes in the protein expression following PDT. We were then able to study the physiological changes due to post-treatment VEGF upregulation by quantifying vascular permeability with in vivo imaging.

  20. Digital Health: Tracking Physiomes and Activity Using Wearable Biosensors Reveals Useful Health-Related Information

    PubMed Central

    Zhou, Gao; Zhou, Wenyu; Schüssler-Fiorenza Rose, Sophia Miryam; Perelman, Dalia; Colbert, Elizabeth; Runge, Ryan; Rego, Shannon; Sonecha, Ria; Datta, Somalee; McLaughlin, Tracey; Snyder, Michael P.

    2017-01-01

    A new wave of portable biosensors allows frequent measurement of health-related physiology. We investigated the use of these devices to monitor human physiological changes during various activities and their role in managing health and diagnosing and analyzing disease. By recording over 250,000 daily measurements for up to 43 individuals, we found personalized circadian differences in physiological parameters, replicating previous physiological findings. Interestingly, we found striking changes in particular environments, such as airline flights (decreased peripheral capillary oxygen saturation [SpO2] and increased radiation exposure). These events are associated with physiological macro-phenotypes such as fatigue, providing a strong association between reduced pressure/oxygen and fatigue on high-altitude flights. Importantly, we combined biosensor information with frequent medical measurements and made two important observations: First, wearable devices were useful in identification of early signs of Lyme disease and inflammatory responses; we used this information to develop a personalized, activity-based normalization framework to identify abnormal physiological signals from longitudinal data for facile disease detection. Second, wearables distinguish physiological differences between insulin-sensitive and -resistant individuals. Overall, these results indicate that portable biosensors provide useful information for monitoring personal activities and physiology and are likely to play an important role in managing health and enabling affordable health care access to groups traditionally limited by socioeconomic class or remote geography. PMID:28081144

  1. The Electrooculogram and a New Blink Detection Algorithm

    DTIC Science & Technology

    2015-10-30

    applications, and physiological monitoring has proven quite helpful with this assessment. One such physiological signal , the electrooculogram ( EOG ...significantly improve performance. One such physiological signal , the electrooculogram ( EOG ), can provide blink rate and blink duration measures. Blink...that such variability substantiates the need for blink detection algorithms, using the EOG signal , that are robust to noise, artifacts, and intra- and

  2. Recommendations for standardizing validation procedures assessing physical activity of older persons by monitoring body postures and movements.

    PubMed

    Lindemann, Ulrich; Zijlstra, Wiebren; Aminian, Kamiar; Chastin, Sebastien F M; de Bruin, Eling D; Helbostad, Jorunn L; Bussmann, Johannes B J

    2014-01-10

    Physical activity is an important determinant of health and well-being in older persons and contributes to their social participation and quality of life. Hence, assessment tools are needed to study this physical activity in free-living conditions. Wearable motion sensing technology is used to assess physical activity. However, there is a lack of harmonisation of validation protocols and applied statistics, which make it hard to compare available and future studies. Therefore, the aim of this paper is to formulate recommendations for assessing the validity of sensor-based activity monitoring in older persons with focus on the measurement of body postures and movements. Validation studies of body-worn devices providing parameters on body postures and movements were identified and summarized and an extensive inter-active process between authors resulted in recommendations about: information on the assessed persons, the technical system, and the analysis of relevant parameters of physical activity, based on a standardized and semi-structured protocol. The recommended protocols can be regarded as a first attempt to standardize validity studies in the area of monitoring physical activity.

  3. Implementation of ICP-MS protocols for uranium urinary measurements in worker monitoring.

    PubMed

    Baglan, N; Cossonnet, C; Trompier, F; Ritt, J; Bérard, P

    1999-10-01

    The uranium concentration in human urine spiked with natural uranium and rat urine containing metabolized depleted uranium was determined by ICP-MS. The use of ICP-MS was investigated without any chemical treatment or after the different stages of a purification protocol currently carried out for routine monitoring. In the case of spiked urine, the measured uranium concentrations were consistent with those certified by an intercomparison network in radiotoxicological analysis (PROCORAD) and with those obtained by alpha spectrometry in the case of the urine containing metabolized uranium. The quantitative information which could be obtained in the different protocols investigated shows the extent to which ICP-MS provides greater flexibility for setting up appropriate monitoring approaches in radiation protection routines and accidental situations. This is due to the combination of high sensitivity and the accuracy with which traces of uranium in urine can be determined in a shorter time period. Moreover, it has been shown that ICP-MS measurement can be used to quantify the 235U isotope, which is useful for characterizing the nature of the uranium compound, but difficult to perform using alpha spectrometry.

  4. An Efficient User Authentication and User Anonymity Scheme with Provably Security for IoT-Based Medical Care System.

    PubMed

    Li, Chun-Ta; Wu, Tsu-Yang; Chen, Chin-Ling; Lee, Cheng-Chi; Chen, Chien-Ming

    2017-06-23

    In recent years, with the increase in degenerative diseases and the aging population in advanced countries, demands for medical care of older or solitary people have increased continually in hospitals and healthcare institutions. Applying wireless sensor networks for the IoT-based telemedicine system enables doctors, caregivers or families to monitor patients' physiological conditions at anytime and anyplace according to the acquired information. However, transmitting physiological data through the Internet concerns the personal privacy of patients. Therefore, before users can access medical care services in IoT-based medical care system, they must be authenticated. Typically, user authentication and data encryption are most critical for securing network communications over a public channel between two or more participants. In 2016, Liu and Chung proposed a bilinear pairing-based password authentication scheme for wireless healthcare sensor networks. They claimed their authentication scheme cannot only secure sensor data transmission, but also resist various well-known security attacks. In this paper, we demonstrate that Liu-Chung's scheme has some security weaknesses, and we further present an improved secure authentication and data encryption scheme for the IoT-based medical care system, which can provide user anonymity and prevent the security threats of replay and password/sensed data disclosure attacks. Moreover, we modify the authentication process to reduce redundancy in protocol design, and the proposed scheme is more efficient in performance compared with previous related schemes. Finally, the proposed scheme is provably secure in the random oracle model under ECDHP.

  5. Linking community-based monitoring to water policy: Perceptions of citizen scientists.

    PubMed

    Carlson, Tyler; Cohen, Alice

    2018-05-05

    This paper examines the relationships between Community-Based Water Monitoring (CBM) and government-led water initiatives. Drawing on a cross-Canada survey of over one hundred organizations, we explore the reasons why communities undertake CBM, the monitoring protocols they follow, and the extent to which CBM program members feel their findings are incorporated into formal (i.e., government-led) decision-making processes. Our results indicate that despite following standardized and credible monitoring protocols, fewer than half of CBM organizations report that their data is being used to inform water policy at any level of government. Moreover, respondents report higher rates of cooperation and data-sharing between CBM organizations themselves than between CBM organizations and their respective governments. These findings are significant, because many governments continue to express support for CBM. We explore the barriers between CBM data collection and government policy, and suggest that structural barriers include lack of multi-year funding, inconsistent protocols, and poor communication. More broadly, we argue that the distinction between formal and informal programming is unclear, and that addressing known CBM challenges will rely on a change in perception: CBM cannot simply be a less expensive alternative to government-driven data collection. Copyright © 2018 The Authors. Published by Elsevier Ltd.. All rights reserved.

  6. An Energy-Efficient MAC Protocol for Medical Emergency Monitoring Body Sensor Networks

    PubMed Central

    Zhang, Chongqing; Wang, Yinglong; Liang, Yongquan; Shu, Minglei; Chen, Changfang

    2016-01-01

    Medical emergency monitoring body sensor networks (BSNs) monitor the occurrence of medical emergencies and are helpful for the daily care of the elderly and chronically ill people. Such BSNs are characterized by rare traffic when there is no emergency occurring, high real-time and reliable requirements of emergency data and demand for a fast wake-up mechanism for waking up all nodes when an emergency happens. A beacon-enabled MAC protocol is specially designed to meet the demands of medical emergency monitoring BSNs. The rarity of traffic is exploited to improve energy efficiency. By adopting a long superframe structure to avoid unnecessary beacons and allocating most of the superframe to be inactive periods, the duty cycle is reduced to an extremely low level to save energy. Short active time slots are interposed into the superframe and shared by all of the nodes to deliver the emergency data in a low-delay and reliable way to meet the real-time and reliable requirements. The interposition slots can also be used by the coordinator to broadcast network demands to wake-up all nodes in a low-delay and energy-efficient way. Experiments display that the proposed MAC protocol works well in BSNs with low emergency data traffic. PMID:26999145

  7. Medical Electronics and Physiological Measurement.

    ERIC Educational Resources Information Center

    Cochrane, T.

    1989-01-01

    Described are developments in medical electronics and physiological measurement. Discussed are electrocardiology, audiology, and urology as mature applications; applied potential tomography, magnetic stimulation of nerves, and laser Doppler flowmetry as new techniques; and optical sensors, ambulatory monitoring, and biosensors as future…

  8. The ICT monitoring system of the ASTRI SST-2M prototype proposed for the Cherenkov Telescope Array

    NASA Astrophysics Data System (ADS)

    Gianotti, F.; Bruno, P.; Tacchini, A.; Conforti, V.; Fioretti, V.; Tanci, C.; Grillo, A.; Leto, G.; Malaguti, G.; Trifoglio, M.

    2016-08-01

    In the framework of the international Cherenkov Telescope Array (CTA) observatory, the Italian National Institute for Astrophysics (INAF) has developed a dual mirror, small sized, telescope prototype (ASTRI SST-2M), installed in Italy at the INAF observing station located at Serra La Nave, Mt. Etna. The ASTRI SST-2M prototype is the basis of the ASTRI telescopes that will form the mini-array proposed to be installed at the CTA southern site during its preproduction phase. This contribution presents the solutions implemented to realize the monitoring system for the Information and Communication Technology (ICT) infrastructure of the ASTRI SST-2M prototype. The ASTRI ICT monitoring system has been implemented by integrating traditional tools used in computer centers, with specific custom tools which interface via Open Platform Communication Unified Architecture (OPC UA) to the Alma Common Software (ACS) that is used to operate the ASTRI SST-2M prototype. The traditional monitoring tools are based on Simple Network Management Protocol (SNMP) and commercial solutions and features embedded in the devices themselves. They generate alerts by email and SMS. The specific custom tools convert the SNMP protocol into the OPC UA protocol and implement an OPC UA server. The server interacts with an OPC UA client implemented in an ACS component that, through the ACS Notification Channel, sends monitor data and alerts to the central console of the ASTRI SST-2M prototype. The same approach has been proposed also for the monitoring of the CTA onsite ICT infrastructures.

  9. A reliable transmission protocol for ZigBee-based wireless patient monitoring.

    PubMed

    Chen, Shyr-Kuen; Kao, Tsair; Chan, Chia-Tai; Huang, Chih-Ning; Chiang, Chih-Yen; Lai, Chin-Yu; Tung, Tse-Hua; Wang, Pi-Chung

    2012-01-01

    Patient monitoring systems are gaining their importance as the fast-growing global elderly population increases demands for caretaking. These systems use wireless technologies to transmit vital signs for medical evaluation. In a multihop ZigBee network, the existing systems usually use broadcast or multicast schemes to increase the reliability of signals transmission; however, both the schemes lead to significantly higher network traffic and end-to-end transmission delay. In this paper, we present a reliable transmission protocol based on anycast routing for wireless patient monitoring. Our scheme automatically selects the closest data receiver in an anycast group as a destination to reduce the transmission latency as well as the control overhead. The new protocol also shortens the latency of path recovery by initiating route recovery from the intermediate routers of the original path. On the basis of a reliable transmission scheme, we implement a ZigBee device for fall monitoring, which integrates fall detection, indoor positioning, and ECG monitoring. When the triaxial accelerometer of the device detects a fall, the current position of the patient is transmitted to an emergency center through a ZigBee network. In order to clarify the situation of the fallen patient, 4-s ECG signals are also transmitted. Our transmission scheme ensures the successful transmission of these critical messages. The experimental results show that our scheme is fast and reliable. We also demonstrate that our devices can seamlessly integrate with the next generation technology of wireless wide area network, worldwide interoperability for microwave access, to achieve real-time patient monitoring.

  10. Infection control in healthcare settings: perspectives for mfDNA analysis in monitoring sanitation procedures.

    PubMed

    Valeriani, Federica; Protano, Carmela; Gianfranceschi, Gianluca; Cozza, Paola; Campanella, Vincenzo; Liguori, Giorgio; Vitali, Matteo; Divizia, Maurizio; Romano Spica, Vincenzo

    2016-08-09

    Appropriate sanitation procedures and monitoring of their actual efficacy represent critical points for improving hygiene and reducing the risk of healthcare-associated infections. Presently, surveillance is based on traditional protocols and classical microbiology. Innovation in monitoring is required not only to enhance safety or speed up controls but also to prevent cross infections due to novel or uncultivable pathogens. In order to improve surveillance monitoring, we propose that biological fluid microflora (mf) on reprocessed devices is a potential indicator of sanitation failure, when tested by an mfDNA-based approach. The survey focused on oral microflora traces in dental care settings. Experimental tests (n = 48) and an "in field" trial (n = 83) were performed on dental instruments. Conventional microbiology and amplification of bacterial genes by multiple real-time PCR were applied to detect traces of salivary microflora. Six different sanitation protocols were considered. A monitoring protocol was developed and performance of the mfDNA assay was evaluated by sensitivity and specificity. Contaminated samples resulted positive for saliva traces by the proposed approach (CT < 35). In accordance with guidelines, only fully sanitized samples were considered negative (100 %). Culture-based tests confirmed disinfectant efficacy, but failed in detecting incomplete sanitation. The method provided sensitivity and specificity over 95 %. The principle of detecting biological fluids by mfDNA analysis seems promising for monitoring the effectiveness of instrument reprocessing. The molecular approach is simple, fast and can provide a valid support for surveillance in dental care or other hospital settings.

  11. Validation of the Pangao PG-800B11 blood pressure monitor according to the European Society of Hypertension and the British Hypertension Society protocols.

    PubMed

    Bing, Sen; Zhang, Cunhai; Wang, Liping; Li, Linyi; Wan, Yi

    2014-12-01

    The study aimed to determine the accuracy of the fully automated oscillometric upper-arm blood pressure (BP) monitor Pangao PG-800B11 according to the European Society of Hypertension-International Protocol (ESH-IP) revision 2010 and the British Hypertension Society (BHS) protocol 1993. Data from 33 participants were initially examined according to the ESH-IP revision 2010. Furthermore, 52 participants were then enrolled to fulfill the BHS protocol requirements. In all participants, sequential left arm measurements were performed by two trained observers using a mercury sphygmomanometer and one supervisor using the device. The protocols' requirements were followed precisely. The device passed all parts of the ESH protocol for systolic blood pressure (SBP) and diastolic blood pressure (DBP) and was graded A according to the criteria of the BHS protocol for both SBP and DBP. The A/A grade was achieved in low (<130/80 mmHg), medium (130-160/80-100 mmHg), and high (>160/100 mmHg) BP categories. The mean BP difference between PG-800B11 and observers in the 85 participants was -0.6±5.0 mmHg for SBP and -0.6±4.5 mmHg for DBP; thus, the device also fulfilled the requirements of the Association for the Advancement of Medical Instrumentation (AAMI). The Pangao PG-800B11 passed all requirements of the ESH-IP revision 2010 and achieved A/A grade of the BHS protocol across a wide range of BPs.

  12. A MORE COST-EFFECTIVE EMAP-ESTUARIES BENTHIC MACROFAUNAL SAMPLING PROTOCOL

    EPA Science Inventory

    The standard benthic macrofaunal sampling protocol in the U.S. Environmental Protection Agency's Pacific Coast Environmental Monitoring and Assessment Program (EMAP) is to collect a minimum of 30 random benthic samples per reporting unit (e.g., estuary) using a 0.1 m2 grab and to...

  13. A MORE COST-EFFECTIVE EMAP BENTHIC MACROFAUNAL SAMPLING PROTOCOL

    EPA Science Inventory

    Benthic macrofaunal sampling protocols in the U.S. Environmental Protection Agency's Environmental Monitoring and Assessment Program (EMAP) are to collect 30 to 50 random benthic macrofauna [defined as animals retained on a 0.5 mm (East and Gulf Coasts, USA) or a 1.0 mm mesh siev...

  14. SmartStuff: A case study of a smart water bottle.

    PubMed

    Jovanov, Emil; Nallathimmareddygari, Vindhya R; Pryor, Jonathan E

    2016-08-01

    The rapid growth of Internet of Things (IoT) and miniature wearable biosensors have generated new opportunities for personalized eHealth and mHealth services. Smart objects equipped with physiological sensors can provide robust monitoring of activities of daily living and context for wearable physiological sensors. We present a case study of an intelligent water bottle that can precisely measure the amount of liquid in the bottle, monitor activity using inertial sensors, and physiological parameters using a touch and photoplethysmographic sensor. We evaluate two system configurations: a smart water bottle integrated into a personal body sensor network and a cloud based device. This paper presents system organization and the results from preliminary field testing of the prototype device.

  15. Measurements, modeling, control and simulation - as applied to the human left ventricle for purposeful physiological monitoring.

    NASA Technical Reports Server (NTRS)

    Ghista, D. N.; Rasmussen, D. N.; Linebarger, R. N.; Sandler, H.

    1971-01-01

    Interdisciplinary engineering research effort in studying the intact human left ventricle has been employed to physiologically monitor the heart and to obtain its 'state-of-health' characteristics. The left ventricle was selected for this purpose because it plays a key role in supplying energy to the body cells. The techniques for measurement of the left ventricular geometry are described; the geometry is effectively displayed to bring out the abnormalities in cardiac function. Methods of mathematical modeling, which make it possible to determine the performance of the intact left ventricular muscle, are also described. Finally, features of a control system for the left ventricle for predicting the effect of certain physiological stress situations on the ventricle performance are discussed.

  16. Design of Plant Eco-physiology Monitoring System Based on Embedded Technology

    NASA Astrophysics Data System (ADS)

    Li, Yunbing; Wang, Cheng; Qiao, Xiaojun; Liu, Yanfei; Zhang, Xinlu

    A real time system has been developed to collect plant's growth information comprehensively. Plant eco-physiological signals can be collected and analyzed effectively. The system adopted embedded technology: wireless sensors network collect the eco-physiological information. Touch screen and ARM microprocessor make the system work independently without PC. The system is versatile and all parameters can be set by the touch screen. Sensors' intelligent compensation can be realized in this system. Information can be displayed by either graphically or in table mode. The ARM microprocessor provides the interface to connect with the internet, so the system support remote monitoring and controlling. The system has advantages of friendly interface, flexible construction and extension. It's a good tool for plant's management.

  17. Sheep (Ovis aries) as a Model for Cardiovascular Surgery and Management before, during, and after Cardiopulmonary Bypass

    PubMed Central

    DiVincenti, Louis; Westcott, Robin; Lee, Candice

    2014-01-01

    Because of its similarity to humans in important respects, sheep (Ovis aries) are a common animal model for translational research in cardiovascular surgery. However, some unique aspects of sheep anatomy and physiology present challenges to its use in these complicated experiments. In this review, we discuss relevant anatomy and physiology of sheep and discuss management before, during, and after procedures requiring cardiopulmonary bypass to provide a concise source of information for veterinarians, technicians, and researchers developing and implementing protocols with this model. PMID:25255065

  18. QoS and energy aware cooperative routing protocol for wildfire monitoring wireless sensor networks.

    PubMed

    Maalej, Mohamed; Cherif, Sofiane; Besbes, Hichem

    2013-01-01

    Wireless sensor networks (WSN) are presented as proper solution for wildfire monitoring. However, this application requires a design of WSN taking into account the network lifetime and the shadowing effect generated by the trees in the forest environment. Cooperative communication is a promising solution for WSN which uses, at each hop, the resources of multiple nodes to transmit its data. Thus, by sharing resources between nodes, the transmission quality is enhanced. In this paper, we use the technique of reinforcement learning by opponent modeling, optimizing a cooperative communication protocol based on RSSI and node energy consumption in a competitive context (RSSI/energy-CC), that is, an energy and quality-of-service aware-based cooperative communication routing protocol. Simulation results show that the proposed algorithm performs well in terms of network lifetime, packet delay, and energy consumption.

  19. Treat-to-target trials in diabetes.

    PubMed

    Wangnoo, Subhash K; Sethi, Bipin; Sahay, Rakesh K; John, Mathew; Ghosal, Samit; Sharma, Surendra K

    2014-03-01

    Treat-to-target is a therapeutic concept that considers well defined and specific physiologic targets as aims in controlling the pathophysiology of the disease. It has been widely used in diseases that pathophysiology includes, chronic metabolic and physiological disturbances, namely rheumatic conditions, vascular medicine and diabetes. In diabetes, the availability of "gold-standard" quantitative measures like fasting plasma glucose and glycated hemoglobin make the application of treat-to-target trials especially pertinent. Treatment modalities which have used single therapeutic agents or combinations or in combination with a variety of titration algorithms and implementation protocols have broadened our understanding of diabetes management with specific reference to insulin initiation and maintenance. Treat-to-target trials have been used to investigate a wide variety of questions including efficacy, safety, effect of treatment on comorbidities and patient satisfaction, ideal mechanisms to implement insulin initiation etc. A more generalized acceptance and implementation of treat-to-target trials may finally revolutionize diabetes management by combining aspects of individual care with standard treatment protocols.

  20. Data acquisition, detection and estimation for structural health monitoring.

    DOT National Transportation Integrated Search

    2014-05-01

    This project deals with using a wireless sensor network for structural health monitoring. It includes two objectives: (1) to develop : energy-efficient protocols for sensing and communication that are suitable for battery-powered sensor nodes; (2) to...

Top