Evans, Adam R; Robinson, Renã A S
2013-11-01
Recently, we reported a novel proteomics quantitation scheme termed "combined precursor isotopic labeling and isobaric tagging (cPILOT)" that allows for the identification and quantitation of nitrated peptides in as many as 12-16 samples in a single experiment. cPILOT offers enhanced multiplexing and posttranslational modification specificity, however excludes global quantitation for all peptides present in a mixture and underestimates reporter ion ratios similar to other isobaric tagging methods due to precursor co-isolation. Here, we present a novel chemical workflow for cPILOT that can be used for global tagging of all peptides in a mixture. Specifically, through low pH precursor dimethylation of tryptic or LysC peptides followed by high pH tandem mass tags, the same reporter ion can be used twice in a single experiment. Also, to improve triple-stage mass spectrometry (MS(3) ) data acquisition, a selective MS(3) method that focuses on product selection of the y1 fragment of lysine-terminated peptides is incorporated into the workflow. This novel cPILOT workflow has potential for global peptide quantitation that could lead to enhanced sample multiplexing and increase the number of quantifiable spectra obtained from MS(3) acquisition methods. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Hu, Kang; Fiedler, Thorsten; Blanco, Laura; Geissen, Sven-Uwe; Zander, Simon; Prieto, David; Blanco, Angeles; Negro, Carlos; Swinnen, Nathalie
2017-11-10
A pilot-scale reverse osmosis (RO) followed behind a membrane bioreactor (MBR) was developed for the desalination to reuse wastewater in a PVC production site. The solution-diffusion-film model (SDFM) based on the solution-diffusion model (SDM) and the film theory was proposed to describe rejections of electrolyte mixtures in the MBR effluent which consists of dominant ions (Na + and Cl - ) and several trace ions (Ca 2+ , Mg 2+ , K + and SO 4 2- ). The universal global optimisation method was used to estimate the ion permeability coefficients (B) and mass transfer coefficients (K) in SDFM. Then, the membrane performance was evaluated based on the estimated parameters which demonstrated that the theoretical simulations were in line with the experimental results for the dominant ions. Moreover, an energy analysis model with the consideration of limitation imposed by the thermodynamic restriction was proposed to analyse the specific energy consumption of the pilot-scale RO system in various scenarios.
Pilot applications of electrochemical chloride extraction on concrete piers in Virginia.
DOT National Transportation Integrated Search
1996-01-01
Applying a temporary electric field between the concrete surface and the rebars can expel or remove chloride ions from salt-contaminated reinforced concrete, which will mitigate rebar corrosion. A new method for the permanent rehabilitation of concre...
2008-08-01
Administration NDBA N-nitrosodi-n-butylamine NDEA N-nitrosodiethylamine NDMA N-nitrosodimethylamine NDPA N-nitrosodi-n-propylamine v ACRONYMS...spectrometry (IC-MS/MS). Nitrosamines were analyzed using EPA Method 521. N-nitrosodimethylamine ( NDMA ) was 2.6 parts per trillion (ppt) with a detection...and metals (Ca, Cu, Fe, Mg, Mn, K, Na , and Zn). Specific methods are listed in Table 5. ** N-nitrosodimethylamine ( NDMA ), N-nitrosodiethylamine
Li, Xiaobing; Shi, Fuguo; Gu, Pan; Liu, Lingye; He, Hua; Ding, Li
2014-04-01
A simple and sensitive HPLC-MS/MS method was developed and fully validated for the simultaneous determination of amygdalin (AD) and paeoniflorin (PF) in human plasma. For both analytes, the method exhibited high sensitivity (LLOQs of 0.6ng/mL) by selecting the ammonium adduct ions ([M+NH4](+)) as the precursor ions and good linearity over the concentration range of 0.6-2000ng/mL with the correlation coefficients>0.9972. The intra- and inter-day precision was lower than 10% in relation to relative standard deviation, while accuracy was within ±2.3% in terms of relative error for both analytes. The developed method was successfully applied to a pilot pharmacokinetic study of AD and PF in healthy volunteers after intravenous infusion administration of Huoxue-Tongluo lyophilized powder for injection. Copyright © 2014 Elsevier B.V. All rights reserved.
Nuclear electric propulsion options for piloted Mars missions
NASA Technical Reports Server (NTRS)
George, Jeffrey A.
1993-01-01
Three nuclear electric propulsion (NEP) systems are discussed. The three systems are as follows: a system based on current SP-100 technology; a potassium Rankine-cycle based power conversion system, and an argon ion thruster system. The system will be researched for implementation in several possible vehicle configurations. The following are among the possible Mars vehicle configurations: a piloted 15 MWe multi-reactor vehicle; a piloted 10 MWe vehicle with ECCV; a piloted 10 MWe modular vehicle; piloted 10 and 15 MWe vehicles with ECCV and MEV; a piloted 5 MWe vehicle with ECCV; a 5 MWe cargo vehicle with 2 MEV's; and a 2.5 MWe vehicle with MEV.
Hu, Yue; Boyer, Treavor H
2017-05-15
The application of bicarbonate-form anion exchange resin and sodium bicarbonate salt for resin regeneration was investigated in this research is to reduce chloride ion release during treatment and the disposal burden of sodium chloride regeneration solution when using traditional chloride-form ion exchange (IX). The target contaminant in this research was dissolved organic carbon (DOC). The performance evaluation was conducted in a completely mixed flow reactor (CMFR) IX configuration. A process model that integrated treatment and regeneration was investigated based on the characteristics of configuration. The kinetic and equilibrium experiments were performed to obtain required parameters for the process model. The pilot plant tests were conducted to validate the model as well as provide practical understanding on operation. The DOC concentration predicted by the process model responded to the change of salt concentration in the solution, and showed a good agreement with pilot plant data with less than 10% difference in terms of percentage removal. Both model predictions and pilot plant tests showed over 60% DOC removal by bicarbonate-form resin for treatment and sodium bicarbonate for regeneration, which was comparable to chloride-form resin for treatment and sodium chloride for regeneration. Lastly, the DOC removal was improved by using higher salt concentration for regeneration. Copyright © 2017 Elsevier Ltd. All rights reserved.
Ion Torrent sequencing as a tool for mutation discovery in the flax (Linum usitatissimum L.) genome.
Galindo-González, Leonardo; Pinzón-Latorre, David; Bergen, Erik A; Jensen, Dustin C; Deyholos, Michael K
2015-01-01
Detection of induced mutations is valuable for inferring gene function and for developing novel germplasm for crop improvement. Many reverse genetics approaches have been developed to identify mutations in genes of interest within a mutagenized population, including some approaches that rely on next-generation sequencing (e.g. exome capture, whole genome resequencing). As an alternative to these genome or exome-scale methods, we sought to develop a scalable and efficient method for detection of induced mutations that could be applied to a small number of target genes, using Ion Torrent technology. We developed this method in flax (Linum usitatissimum), to demonstrate its utility in a crop species. We used an amplicon-based approach in which DNA samples from an ethyl methanesulfonate (EMS)-mutagenized population were pooled and used as template in PCR reactions to amplify a region of each gene of interest. Barcodes were incorporated during PCR, and the pooled amplicons were sequenced using an Ion Torrent PGM. A pilot experiment with known SNPs showed that they could be detected at a frequency > 0.3% within the pools. We then selected eight genes for which we wanted to discover novel mutations, and applied our approach to screen 768 individuals from the EMS population, using either the Ion 314 or Ion 316 chips. Out of 29 potential mutations identified after processing the NGS reads, 16 mutations were confirmed using Sanger sequencing. The methodology presented here demonstrates the utility of Ion Torrent technology in detecting mutation variants in specific genome regions for large populations of a species such as flax. The methodology could be scaled-up to test >100 genes using the higher capacity chips now available from Ion Torrent.
On the effectiveness of ion range determination from in-beam PET data
NASA Astrophysics Data System (ADS)
Fiedler, Fine; Shakirin, Georgy; Skowron, Judith; Braess, Henning; Crespo, Paulo; Kunath, Daniela; Pawelke, Jörg; Pönisch, Falk; Enghardt, Wolfgang
2010-04-01
At present, in-beam positron emission tomography (PET) is the only method for in vivo and in situ range verification in ion therapy. At the GSI Helmholtzzentrum für Schwerionenforschung GmbH (GSI) Darmstadt, Germany, a unique in-beam PET installation has been operated from 1997 until the shut down of the carbon ion therapy facility in 2008. Therapeutic irradiation by means of 12C ion beams of more than 400 patients have been monitored. In this paper a first quantitative study on the accuracy of the in-beam PET method to detect range deviations between planned and applied treatment in clinically relevant situations using simulations based on clinical data is presented. Patient treatment plans were used for performing simulations of positron emitter distributions. For each patient a range difference of ± 6 mm in water was applied and compared to simulations without any changes. The comparisons were performed manually by six experienced evaluators for data of 81 patients. The number of patients required for the study was calculated using the outcome of a pilot study. The results indicate a sensitivity of (91 ± 3)% and a specificity of (96 ± 2)% for detecting an overrange, a reduced range is recognized with a sensitivity of (92 ± 3)% and a specificity of (96 ± 2)%. The positive and the negative predictive value of this method are 94% and 87%, respectively. The interobserver coefficient of variation is between 3 and 8%. The in-beam PET method demonstrated a high sensitivity and specificity for the detection of range deviations. As the range is a most indicative factor of deviations in the dose delivery, the promising results shown in this paper confirm the in-beam PET method as an appropriate tool for monitoring ion therapy.
EVALUATING ION EXCHANGE FOR REMOVING RADIUM FROM GROUNDWATER
This article, the second in a series, focuses on the results of bench- and pilot-scale studies of ion exchange processes for radium removal from groundwater in Lemont, Ill. Batch and column studies indicated a very high resin selectivity for radium compared with common cations. E...
Li, Fuqiang; Li, Guangyu; Zhao, Jinsong; Xiao, Jun; Liu, Zaoxia; Su, Guanfang
2016-06-01
A simple, specific, and sensitive liquid chromatography-mass spectrometry (LC-MS) method for determination of cyasterone in rat plasma was developed in our laboratory. Cucurbitacin B was used as an internal standard (IS). After protein precipitation with twofold volume of acetonitrile, the analyte and IS were separated on a Luna C18 column (100 × 4.6 mm, i.d., 3.0 µm; Phenomenex) by isocratic elution with acetonitrile-water (80:20, v/v) as the mobile phase at a flow rate of 0.4 mL/min. An electrospray ionization source was applied and operated in the positive ion mode; selected ion monitoring scan mode was used for quantification, and the target ions m/z 543.3 for cyasterone and m/z 581.3 for IS were chosen. Good linearity was observed in the concentration range of 0.40-400 ng/mL for cyasterone in rat plasma. Intra-day and inter-day precision were both <7.4%. This method was proved to be suitable for pharmacokinetic studies after oral (5.0 mg/kg) or intravenous (0.5 mg/kg) administration of cyasterone in rats. Copyright © 2015 John Wiley & Sons, Ltd. Copyright © 2015 John Wiley & Sons, Ltd.
Advanced material and approach for metal ions removal from aqueous solutions
Turhanen, Petri A.; Vepsäläinen, Jouko J.; Peräniemi, Sirpa
2015-01-01
A Novel approach to remove metals from aqueous solutions has been developed. The method is based on a resin free, solid, non-toxic, microcrystalline bisphosphonate material, which has very low solubility in water (59 mg/l to ion free Milli-Q water and 13 mg/l to 3.5% NaCl solution). The material has been produced almost quantitatively on a 1 kg scale (it has been prepared also on a pilot scale, ca. 7 kg) and tested successfully for its ability to collect metal cations from different sources, such as ground water and mining process waters. Not only was this material highly efficient at collecting several metal ions out of solution it also proved to be regenerable and reusable over a number of adsorption/desorption, which is crucial for environmental friendliness. This material has several advantages compared to the currently used approaches, such as no need for any precipitation step. PMID:25758924
Injection method of barrier bucket supported by off-aligned electron cooling for CRing of HIAF
NASA Astrophysics Data System (ADS)
Shen, Guo-Dong; Yang, Jian-Cheng; Xia, Jia-Wen; Mao, Li-Jun; Yin, Da-Yu; Chai, Wei-Ping; Shi, Jian; Sheng, Li-Na; Smirnov, A.; Wu, Bo; Zhao, He
2016-08-01
A new accelerator complex, HIAF (the High Intensity Heavy Ion Accelerator Facility), has been approved in China. It is designed to provide intense primary and radioactive ion beams for research in high energy density physics, nuclear physics, atomic physics as well as other applications. In order to achieve a high intensity of up to 5×1011 ppp 238U34+, the Compression Ring (CRing) needs to stack more than 5 bunches transferred from the Booster Ring (BRing). However, the normal bucket to bucket injection scheme can only achieve an intensity gain of 2, so an injection method, fixed barrier bucket (BB) supported by electron cooling, is proposed. To suppress the severe space charge effect during the stacking process, off-alignment is adopted in the cooler to control the transverse emittance. In this paper, simulation and optimization with the BETACOOL program are presented. Supported by New Interdisciplinary and Advanced Pilot Fund of Chinese Academy of Sciences
Electrochemical process for electrode material of spent lithium ion batteries.
Prabaharan, G; Barik, S P; Kumar, N; Kumar, L
2017-10-01
Electrochemical method for recovering cobalt and manganese from electrode materials of spent lithium ion batteries was studied. Electrochemical leaching of cobalt and manganese from electrode material was optimized by varying different process parameters such as time, acid concentration and current density. Both cobalt and manganese could effectively be leached out at a current density of 400A/m 2 in 3h using 2M sulphuric acid. In the subsequent study, the metallic cobalt and electrolytic manganese dioxides was recovered from the leach liquor at 200A/m 2 , pH 2-2.5 and 90°C after removing aluminum. The commercial feasibility of the study was tested in pilot scale. Overall recovery of Co, Cu and Mn was above 96%, 97% and 99%, respectively. Copyright © 2017 Elsevier Ltd. All rights reserved.
Slowey, Aaron J.; Marvin-DiPasquale, Mark
2012-01-01
Conclusions - Despite their intrinsic variability, Hg/Au electrodes fabricated by hand can be used to quantify O2, S(−II), Fe(II), and Mn(II) without calibrating every electrode for every constituent of interest. The pilot ion method can achieve accuracies to within 20% or less, provided that the underlying principle—the independence of slope ratios—is demonstrated for all voltammetric techniques used, and effects of the physicochemical properties of the system on voltammetric signals are addressed through baseline subtraction.
Sullivan, Daniel J.; Blanchard, Stephen F.
1994-01-01
This report describes and presents the sampling design, methods, quality assurance methods and results, and information on how to obtain data collected at eight fixed stations in the upper Illinois River Basin as part of the pilot phase of the National Water-Quality Assessment program. Data were collected monthly from April 1987-August l990; these data were supplemented with data collected during special events, including high and low flows. Each fixed station represents a cross section at which the transport of selected dissolved and suspended materials can be computed. Samples collected monthly and during special events were analyzed for concentrations of major ions, nutrients, trace elements, organic carbon, chlorophyll-a, suspended sediment, and other constituents. Field measurements of water temperature, pH, dissolved oxygen, specific conductance, and indicator bacteria also were made at each site. Samples of suspended sediment were analyzed for concentrations of major ions and trace elements. In addition, samples were analyzed seasonally for concentrations of antimony, bromide, molybdenum, and the radionuclides gross alpha and gross beta.
The Shock and Vibration Bulletin. Part 3. Aerospace Vehicles, Vibro-acoustics
1975-06-01
Corporation, San Diego, California .ANALYSIS AND FLIGHIT TEST CORRELATION OF VIBROACOUS’IIC ENVIRONMENTS ON A REMOTELY PILOTED VEHIICLE... piloted aircraft shown in tic set of specifications calls for extensive flight Figure 1. It is powered by a single, fuselage- test data encompassing the...Company, Hamptnn Virginia c1 DETERMINAf ION OF PROPELLATNT EFFECTIVE MASS PROPERTIES USING MODAL TEST DATAj 15 J. C. Chen and J,. A Garba, Jet Propulsion
Regeneration of pilot-scale ion exchange columns for hexavalent chromium removal.
Korak, Julie A; Huggins, Richard; Arias-Paic, Miguel
2017-07-01
Due to stricter regulations, some drinking water utilities must implement additional treatment processes to meet potable water standards for hexavalent chromium (Cr(VI)), such as the California limit of 10 μg/L. Strong base anion exchange is effective for Cr(VI) removal, but efficient resin regeneration and waste minimization are important for operational, economic and environmental considerations. This study compared multiple regeneration methods on pilot-scale columns on the basis of regeneration efficiency, waste production and salt usage. A conventional 1-Stage regeneration using 2 N sodium chloride (NaCl) was compared to 1) a 2-Stage process with 0.2 N NaCl followed by 2 N NaCl and 2) a mixed regenerant solution with 2 N NaCl and 0.2 N sodium bicarbonate. All methods eluted similar cumulative amounts of chromium with 2 N NaCl. The 2-Stage process eluted an additional 20-30% of chromium in the 0.2 N fraction, but total resin capacity is unaffected if this fraction is recycled to the ion exchange headworks. The 2-Stage approach selectively eluted bicarbonate and sulfate with 0.2 N NaCl before regeneration using 2 N NaCl. Regeneration approach impacted the elution efficiency of both uranium and vanadium. Regeneration without co-eluting sulfate and bicarbonate led to incomplete uranium elution and potential formation of insoluble uranium hydroxides that could lead to long-term resin fouling, decreased capacity and render the resin a low-level radioactive solid waste. Partial vanadium elution occurred during regeneration due to co-eluting sulfate suppressing vanadium release. Waste production and salt usage were comparable for the 1- and 2-Stage regeneration processes with similar operational setpoints with respect to chromium or nitrate elution. Published by Elsevier Ltd.
Paper Spray Mass Spectrometry for the Forensic Analysis of Black Ballpoint Pen Inks
NASA Astrophysics Data System (ADS)
Amador, Victoria Silva; Pereira, Hebert Vinicius; Sena, Marcelo Martins; Augusti, Rodinei; Piccin, Evandro
2017-09-01
This article describes the use of paper spray mass spectrometry (PS-MS) for the direct analysis of black ink writings made with ballpoint pens. The novel approach was developed in a forensic context by first performing the classification of commercially available ballpoint pens according to their brands. Six of the most commonly worldwide utilized brands (Bic, Paper Mate, Faber Castell, Pentel, Compactor, and Pilot) were differentiated according to their characteristic chemical patterns obtained by PS-MS. MS on the negative ion mode at a mass range of m/ z 100-1000 allowed prompt discrimination just by visual inspection. On the other hand, the concept of relative ion intensity (RII) and the analysis at other mass ranges were necessary for the differentiation using the positive ion mode. PS-MS combined with partial least squares (PLS) was utilized to monitor changes on the ink chemical composition after light exposure (artificial aging studies). The PLS model was optimized by variable selection, which allowed the identification of the most influencing ions on the degradation process. The feasibility of the method on forensic investigations was also demonstrated in three different applications: (1) analysis of overlapped fresh ink lines, (2) analysis of old inks from archived documents, and (3) detection of alterations (simulated forgeries) performed on archived documents. [Figure not available: see fulltext.
CCQM Pilot Study CCQM-P140: Quantitative surface analysis of multi-element alloy films
NASA Astrophysics Data System (ADS)
Kim, Kyung Joong; Jang, Jong Shik; Kim, An Soon; Suh, Jung Ki; Chung, Yong-Duck; Hodoroaba, Vasile-Dan; Wirth, Thomas; Unger, Wolfgang; Kang, Hee Jae; Popov, Oleg; Popov, Inna; Kuselman, Ilya; Lee, Yeon Hee; Sykes, David E.; Wang, Meiling; Wang, Hai; Ogiwara, Toshiya; Nishio, Mitsuaki; Tanuma, Shigeo; Simons, David; Szakal, Christopher; Osborn, William; Terauchi, Shinya; Ito, Mika; Kurokawa, Akira; Fujimoto, Toshiyuki; Jordaan, Werner; Jeong, Chil Seong; Havelund, Rasmus; Spencer, Steve; Shard, Alex; Streeck, Cornelia; Beckhoff, Burkhard; Eicke, Axel; Terborg, Ralf
2015-01-01
A pilot study for a quantitative surface analysis of multi-element alloy films has been performed by the Surface Analysis Working Group (SAWG) of the Consultative Committee for Amount of Substance (CCQM). The aim of this pilot study is to evaluate a protocol for a key comparison to demonstrate the equivalence of measures by National Metrology Institutes (NMIs) and Designated Institutes (DI) for the mole fractions of multi-element alloy films. A Cu(In,Ga)Se2 (CIGS) film with non-uniform depth distribution was chosen as a representative multi-element alloy film. The mole fractions of the reference and the test CIGS films were certified by isotope dilution—inductively coupled plasma/mass spectrometry. A total number counting (TNC) method was used as a method to determine the signal intensities of the constituent elements acquired in SIMS, XPS and AES depth profiling. TNC method is comparable with the certification process because the certified mole fractions are the average values of the films. The mole fractions of the CIGS films were measured by Secondary Ion Mass Spectrometry (SIMS), Auger Electron Spectroscopy (AES), X-ray Photoelectron Spectroscopy (XPS), X-Ray Fluorescence (XRF) Analysis and Electron Probe Micro Analysis (EPMA) with Energy Dispersive X-ray Spectrometry (EDX). Fifteen laboratories from eight NMIs, one DI, and six non-NMIs participated in this pilot study. The average mole fractions of the reported data showed relative standard deviations from 5.5 % to 6.8 % and average relative expanded uncertainties in the range from 4.52 % to 4.86 % for the four test CIGS specimens. These values are smaller than those in the key comparison CCQM-K67 for the measurement of mole fractions of Fe-Ni alloy films. As one result it can be stated that SIMS, XPS and AES protocols relying on the quantification of CIGS films using the TNC method are mature to be used in a CCQM key comparison. Main text. To reach the main text of this paper, click on Final Report. The final report has been peer-reviewed and approved for publication by CCQM.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Steinstraeter, Olaf, E-mail: o.steinstraeter@gsi.de; Gruen, Rebecca; Institut fuer Medizinische Physik und Strahlenschutz, TH-Mittelhessen, Giessen
2012-11-01
Purpose: A method was developed to convert clinically prescribed RBE (Relative Biological Effectiveness)-weighted doses from the approach used at the Heavy-Ion Medical Accelerator (HIMAC) at the National Institute of Radiological Science, Chiba, Japan, to the LEM (Local Effect Model)-based TReatment planning for Particles (TRiP98) approach used in the pilot project at the GSI Helmholtzzentrum, Darmstadt, and the Heidelberg Ion-Beam Therapy Center (HIT). Methods and Materials: The proposed conversion method is based on a simulation of the fixed spread-out Bragg peak (SOBP) depth dose profiles as used for the irradiation at HIMAC by LEM/TRiP98 and a recalculation of the resulting RBE-weightedmore » dose distribution. We present data according to the clinical studies conducted at GSI in the past decade (LEM I), as well as data used in current studies (refined LEM version: LEM IV). Results: We found conversion factors (RBE-weighted dose LEM/RBE-weighted dose HIMAC) reaching from 0.4 to 2.0 for prescribed carbon ion doses from 1 to 60 Gy (RBE) for SOBP extensions ranging from 20 to 120 mm according to the HIMAC approach. A conversion factor of 1.0 was found for approximately 5 Gy (RBE). The conversion factor decreases with increasing prescribed dose. Slightly smaller values for the LEM IV-based data set compared with LEM I were found. A significant dependence of the conversion factor from the SOBP width could be observed in particular for LEM IV, whereas the depth dependence was found to be small. Conclusions: For the interpretation and comparison of clinical trials performed at HIMAC and GSI/HIT, it is of extreme importance to consider these conversion factors because according to the various methods to determine the RBE-weighted dose, similar dose values might not necessarily be related to similar clinical outcomes.« less
Prospects for spinel-stabilized, high-capacity lithium-ion battery cathodes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Croy, Jason R.; Park, Joong Sun; Shin, Youngho
Herein we report early results on efforts to optimize the electrochemical performance of a cathode composed of a lithium- and manganese-rich “layered-layered-spinel” material for lithium-ion battery applications. Pre-pilot scale synthesis leads to improved particle properties compared with lab-scale efforts, resulting in high capacities (≳200 mAh/g) and good energy densities (>700 Wh/kg) in tests with lithium-ion cells. Subsequent surface modifications give further improvements in rate capabilities and high-voltage stability. These results bode well for advances in the performance of this class of lithium- and manganese-rich cathode materials.
Prospects for spinel-stabilized, high-capacity lithium-ion battery cathodes
Croy, Jason R.; Park, Joong Sun; Shin, Youngho; ...
2016-10-13
Herein we report early results on efforts to optimize the electrochemical performance of a cathode composed of a lithium- and manganese-rich “layered-layered-spinel” material for lithium-ion battery applications. Pre-pilot scale synthesis leads to improved particle properties compared with lab-scale efforts, resulting in high capacities (≳200 mAh/g) and good energy densities (>700 Wh/kg) in tests with lithium-ion cells. Subsequent surface modifications give further improvements in rate capabilities and high-voltage stability. These results bode well for advances in the performance of this class of lithium- and manganese-rich cathode materials.
Ion beams in radiotherapy - from tracks to treatment planning
NASA Astrophysics Data System (ADS)
Krämer, M.; Scifoni, E.; Wälzlein, C.; Durante, M.
2012-07-01
Several dozen clinical sites around the world apply beams of fast light ions for radiotherapeutical purposes. Thus there is a vested interest in the various physical and radiobiological processes governing the interaction of ion beams with matter, specifically living systems. We discuss the various modelling steps which lead from basic interactions to the application in actual patient treatment planning. The nano- and microscopic scale is covered by sample calculations with our TRAX code. On the macroscopic scale we feature the TRiP98 treatment planning system, which was clinically used in GSI's radiotherapy pilot project.
High-throughput electrophysiological assays for voltage gated ion channels using SyncroPatch 768PE.
Li, Tianbo; Lu, Gang; Chiang, Eugene Y; Chernov-Rogan, Tania; Grogan, Jane L; Chen, Jun
2017-01-01
Ion channels regulate a variety of physiological processes and represent an important class of drug target. Among the many methods of studying ion channel function, patch clamp electrophysiology is considered the gold standard by providing the ultimate precision and flexibility. However, its utility in ion channel drug discovery is impeded by low throughput. Additionally, characterization of endogenous ion channels in primary cells remains technical challenging. In recent years, many automated patch clamp (APC) platforms have been developed to overcome these challenges, albeit with varying throughput, data quality and success rate. In this study, we utilized SyncroPatch 768PE, one of the latest generation APC platforms which conducts parallel recording from two-384 modules with giga-seal data quality, to push these 2 boundaries. By optimizing various cell patching parameters and a two-step voltage protocol, we developed a high throughput APC assay for the voltage-gated sodium channel Nav1.7. By testing a group of Nav1.7 reference compounds' IC50, this assay was proved to be highly consistent with manual patch clamp (R > 0.9). In a pilot screening of 10,000 compounds, the success rate, defined by > 500 MΩ seal resistance and >500 pA peak current, was 79%. The assay was robust with daily throughput ~ 6,000 data points and Z' factor 0.72. Using the same platform, we also successfully recorded endogenous voltage-gated potassium channel Kv1.3 in primary T cells. Together, our data suggest that SyncroPatch 768PE provides a powerful platform for ion channel research and drug discovery.
Effect of iron(III) ion on moso bamboo pyrolysis under microwave irradiation.
Dong, Qing; Li, Xiangqian; Wang, Zhaoyu; Bi, Yanhong; Yang, Rongling; Zhang, Jinfeng; Luo, Hongzhen; Niu, Miaomiao; Qi, Bo; Lu, Chen
2017-11-01
The effect of iron(III) ion on microwave pyrolysis of moso bamboo was investigated. Hydrofluoric acid washing was used as a pilot process to demineralize moso bamboo in order to eliminate the influences of the other inorganics contained in moso bamboo itself. The results indicated that the addition of iron(III) ion increased the maximal reaction temperatures under microwave condition dependent on the amount of the added iron(III) ion. The production of the non-condensable gases was promoted by the addition of iron(III) ion mainly at the expense of liquid products. Iron(III) ion exhibited the positive effect for syngas production and inhibited the formation of CO 2 and CH 4 . The formation of Fe 2 O 3 and Fe 3 O 4 was found during microwave pyrolysis and the mechanism of the two metallic oxides formation was described in this work. Copyright © 2017 Elsevier Ltd. All rights reserved.
Hadron Cancer Therapy - relative merits of X-ray, proton and carbon beams
NASA Astrophysics Data System (ADS)
Jakel, Oliver
2014-03-01
-Heidelberg University has a long experience in radiotherapy with carbon ions, starting with a pilot project at GSI in 1997. This project was jointly run by the Dep. for Radiation Oncology of Heidelberg University, GSI and the German Cancer Research Center (DKFZ). A hospital based heavy ion center at Heidelberg University, the Heidelberg Ion Beam Therapy Center (HIT) was proposed by the same group in 1998 and started clinical operation in late 2009. Since then nearly 2000 patients were treated with beams of carbon ions and protons. Just recently the operation of the world's first and only gantry for heavy ions also started at HIT. Patient treatments are performed in three rooms. Besides that, a lot of research projects are run in the field of Medical Physics and Radiobiology using a dedicated experimental area and the possibility to use beams of protons, carbon, helium and oxygen ions being delivered with the raster scanning technique.
A Pilot Study of Ion - Molecule Reactions at Temperatures Relevant to the Atmosphere of Titan.
Zymak, Illia; Žabka, Ján; Polášek, Miroslav; Španěl, Patrik; Smith, David
2016-11-01
Reliable theoretical models of the chemical kinetics of the ionosphere of Saturn's moon, Titan, is highly dependent on the precision of the rates of the reactions of ambient ions with hydrocarbon molecules at relevant temperatures. A Variable Temperature Selected Ions Flow Tube technique, which has been developed primarily to study these reactions at temperatures within the range of 200-330 K, is briefly described. The flow tube temperature regulation system and the thermalisation of ions are also discussed. Preliminary studies of two reactions have been carried out to check the reliability and efficacy of kinetics measurements: (i) Rate constants of the reaction of CH 3 + ions with molecular oxygen were measured at different temperatures, which indicate values in agreement with previous ion cyclotron resonance measurements ostensibly made at 300 K. (ii) Formation of CH 3 + ions in the reaction of N 2 + ions with CH 4 molecules were studied at temperatures within the range 240-310 K which showed a small but statistically significant decrease of the ratio of product CH 3 + ions to reactant N 2 + ions with reaction temperature.
Petruzzelli, D; De Florio, L; Dell'Erba, A; Liberti, L; Notarnicola, M; Sengupta, A K
2003-01-01
P-control technologies for municipal wastewater are essentially based on "destructive" methods, that lead to formation of concentrated solid-phases (sludge), usually disposed-off in controlled landfills. Ion exchange, as a "non-destructive" technology, allows for selective removal and simultaneous recovery of pollutants, which can be recycled to the same and/or related productive lines. In this context, the REM NUT process removes nutrient species (HPO4 = , NH4+, K+) present in biologically oxidised municipal effluents and recovers them in the form of struvites (MgNH4PO4; MgKPO4), premium quality slow release fertilisers. The main limitation to the extensive application of this ion exchange based process is the non-availability of selective exchangers for specific removal of nutrient species. This paper illustrates laboratory investigation and pilot scale development of a so-called "P-driven" modified REM NUT scheme based on a new phosphate-selective sorbent developed at Lehigh University, PA, USA.
Rott, Eduard; Kuch, Bertram; Lange, Claudia; Richter, Philipp; Minke, Ralf
2018-06-16
This work investigates the influence of ammonium ions and the organic load (chemical oxygen demand (COD)) on the UV/chlorine AOP regarding the maintenance of free available chlorine (FAC) and elimination of 16 emerging contaminants (ECs) from wastewater treatment plant effluent (WWTE) at pilot scale (UV chamber at 0.4 kW). COD inhibited the FAC maintenance in the UV chamber influent at a ratio of 0.16 mg FAC per mg COD ( k HOCl⁻COD = 182 M −1 s −1 ). An increase in ammonium ion concentration led to a stoichiometric decrease of the FAC concentration in the UV chamber influent. Especially in cold seasons due to insufficient nitrification, the ammonium ion concentration in WWTE can become so high that it becomes impossible to achieve sufficiently high FAC concentrations in the UV chamber influent. For all ECs, the elimination effect by the UV/combined Cl₂ AOP (UV/CC) was not significantly higher than that by sole UV treatment. Accordingly, the UV/chlorine AOP is very sensitive and loses its effectiveness drastically as soon as there is no FAC but only CC in the UV chamber influent. Therefore, within the electrical energy consumption range tested (0.13⁻1 kWh/m³), a stable EC elimination performance of the UV/chlorine AOP cannot be maintained throughout the year.
Multimegawatt electric propulsion system design considerations
NASA Technical Reports Server (NTRS)
Gilland, J. H.; Myers, Roger M.; Patterson, Michael J.
1991-01-01
Piloted Mars Mission Requirements of relatively short trip times and low initial mass in Earth orbit as identified by the NASA Space Exploration Initiative, indicate the need for multimegawatt electric propulsion systems. The design considerations and results for two thruster types, the argon ion, and hydrogen magnetoplasmadynamic thrusters, are addressed in terms of configuration, performance, and mass projections. Preliminary estimates of power management and distribution for these systems are given. Some assessment of these systems' performance in a reference Space Exploration Initiative piloted mission are discussed. Research and development requirements of these systems are also described.
Zou, Xue; Zhou, Wenzhao; Lu, Yan; Shen, Chengyin; Hu, Zongtao; Wang, Hongzhi; Jiang, Haihe; Chu, Yannan
2016-11-01
Esophageal cancer is a prevalent malignancy. There is a considerable demand for developing a fast and noninvasive method to screen out the suspect esophageal cancer patients who may undergo further clinical diagnosis. The exhaled breathes from 29 esophageal cancer patients and 57 healthy people were directly measured using our home-made proton transfer reaction mass spectrometer (PTR-MS). Mann-Whitney U test and stepwise discriminant analysis were applied to identify the ions in the breath mass spectral data which can distinguish cancer cohort from healthy group. Receiver operating characteristics (ROC) analysis was also performed. Seven kinds of ions in the breath mass spectrum, viz., m/z 136, m/z 34, m/z 63, m/z 27, m/z 95, m/z 107 and m/z 45, have been found to distinguish between the esophageal cancer patients and healthy people with a sensitivity of 86.2% and a specificity of 89.5%, respectively. Compared with that from the healthy people, the breath mass spectra from esophageal cancer patients show that the mediant intensities of five kinds of ions were decrease and the rest two kinds of ions were increase. ROC analysis gave the area under the curve (AUC) of 0.943. This pilot study shows that the ionic characteristics of exhaled VOCs detected by PTR-MS may be used to differentiate between the esophageal cancer patients and the healthy people. Although the breath tests for more patients are needed to confirm such results, the present work indicates that the PTR-MS may be a promising method in the esophageal cancer screening. © 2016 Journal of Gastroenterology and Hepatology Foundation and John Wiley & Sons Australia, Ltd.
Test and Evaluation of a Pilot System for Ion Exchange Treatment of Cadmium Cyanide Wastes
1993-09-01
rate, metal concentration and solution chemistry , and temperature. These factors affect the diffusion rate of metal ions from the bulk solution to the...Changes in Cd2+ or CN- resin capacity and removal efficiency after a number of regeneration cycles; • Discharge leakage levels of Cd2+ and CN- after...a filter to remove any suspended solids, an activated-carbon column to remove any organic matter (this step was not utilized since organic levels
2H Stable Isotope Analysis of Tooth Enamel: A Pilot Study
NASA Astrophysics Data System (ADS)
Holobinko, Anastasia; Kemp, Helen; Meier-Augenstein, Wolfram; Prowse, Tracy; Ford, Susan
2010-05-01
Stable isotope analysis of biogenic tissues such as tooth enamel and bone mineral has become a well recognized and increasingly important method for determining provenance of human remains, and has been used successfully in bioarchaeological studies as well as forensic investigations (Lee-Thorp, 2008; Meier-Augenstein and Fraser, 2008). Particularly, 18O and 2H stable isotopes are well established proxies as environmental indicators of climate (temperature) and source water and are therefore considered as indicators of geographic life trajectories of animals and humans (Hobson et al., 2004; Schwarcz and Walker, 2006). While methodology for 2H analysis of human hair, fingernails, and bone collagen is currently used to determine geographic origin and identify possible migration patterns, studies involving the analysis of 2H in tooth enamel appear to be nonexistent in the scientific literature. The apparent lack of research in this area is believed to have two main reasons. (1) Compared to the mineral calcium hydroxylapatite Ca10(PO4)6(OH)2, in tooth enamel forming bio-apatite carbonate ions replace some of the hydroxyl ions at a rate of one CO32 replacing two OH, yet published figures for the degree of substitution vary (Wopenka and Pasteris, 2005). (2) Most probably due to the aforementioned no published protocols exist for sample preparation and analytical method to obtain δ2H-values from the hydroxyl fraction of tooth enamel. This dilemma has been addressed through a pilot study to establish feasibility of 2H stable isotope analysis of ground tooth enamel by continuous-flow isotope ratio mass spectrometry (IRMS) coupled on-line to a high-temperature conversion elemental analyzer (TC/EA). An array of archaeological and modern teeth has been analyzed under different experimental conditions, and results from this pilot study are being presented. References: Lee-Thorp, J.A. (2008) Archaeometry, 50, 925-950 Meier-Augenstein, W. and Fraser, I. (2008) Science & Justice, 48, 153-159 Hobson, K.A., Bowen, G.J., Wassenaar, L.I., Ferrand, Y. and Lormee, H. (2004) Oecologia, 141, 477-488 Schwarcz, H.P. and Walker, P.L. (2006) American Journal of Physical Anthropology, 129, 160 Wopenka, B. and Pasteris, J.D. (2005) Materials Science and Engineering C, 25, 131-143
Role of Ca++ Influx via Epidermal TRP Ion Channels
2014-10-01
determine the epidermis’ response to activation of TRP channels. 2 Keywords Amputation stump, irritant dermatitis , epidermis, skin barrier function, TRP...the personnel who is in contact with subjects. All these requirements were addressed satisfactorily. Impact We view the pilot finding that
Estimation of Time-Varying Pilot Model Parameters
NASA Technical Reports Server (NTRS)
Zaal, Peter M. T.; Sweet, Barbara T.
2011-01-01
Human control behavior is rarely completely stationary over time due to fatigue or loss of attention. In addition, there are many control tasks for which human operators need to adapt their control strategy to vehicle dynamics that vary in time. In previous studies on the identification of time-varying pilot control behavior wavelets were used to estimate the time-varying frequency response functions. However, the estimation of time-varying pilot model parameters was not considered. Estimating these parameters can be a valuable tool for the quantification of different aspects of human time-varying manual control. This paper presents two methods for the estimation of time-varying pilot model parameters, a two-step method using wavelets and a windowed maximum likelihood estimation method. The methods are evaluated using simulations of a closed-loop control task with time-varying pilot equalization and vehicle dynamics. Simulations are performed with and without remnant. Both methods give accurate results when no pilot remnant is present. The wavelet transform is very sensitive to measurement noise, resulting in inaccurate parameter estimates when considerable pilot remnant is present. Maximum likelihood estimation is less sensitive to pilot remnant, but cannot detect fast changes in pilot control behavior.
Spectroscopic determination of photospheric parameters and chemical abundances of 6 K-type stars^
NASA Astrophysics Data System (ADS)
Affer, L.; Micela, G.; Morel, T.; Sanz-Forcada, J.; Favata, F.
2005-04-01
High resolution, high -S/N- ratio optical spectra have been obtained for a sample of 6 K-type dwarf and subgiant stars, and have been analysed with three different LTE methods in order to derive detailed photospheric parameters and abundances and to compare the characteristics of analysis techniques. The results have been compared with the aim of determining the most robust method to perform complete spectroscopic analyses of K-type stars, and in this perspective the present work must be considered as a pilot study. In this context we have determined the abundance ratios with respect to iron of several elements. In the first method the photospheric parameters (T_eff, log g, and ξ) and metal abundances are derived using measured equivalent widths and Kurucz LTE model atmospheres as input for the MOOG software code. The analysis proceeds in an iterative way, and relies on the excitation equilibrium of the ion{Fe}{i} lines for determining the effective temperature and microturbulence, and on the ionization equilibrium of the ion{Fe}{i} and ion{Fe}{ii} lines for determining the surface gravity and the metallicity. The second method follows a similar approach, but discards the ion{Fe}{i} low excitation potential transitions (which are potentially affected by non-LTE effects) from the initial line list, and relies on the B-V colour index to determine the temperature. The third method relies on the detailed fitting of the 6162 Å ion{Ca}{i} line to derive the surface gravity, using the same restricted line list as the second method. Methods 1 and 3 give consistent results for the program stars; in particular the comparison between the results obtained shows that the ion{Fe}{i} low-excitation potential transitions do not appear significantly affected by non-LTE effects (at least for the subgiant stars), as suggested by the good agreement of the atmospheric parameters and chemical abundances derived. The second method leads to systematically lower T_eff and log g values with respect to the first one, and a similar trend is shown by the chemical abundances (with the exception of the oxygen abundance). These differences, apart from residual non-LTE effects, may be a consequence of the colour-T_eff scale used. The α-elements have abundance ratios consistent with the solar values for all the program stars, as expected for “normal” disk stars. The first method appears to be the most reliable one, as it is self-consistent, it always leads to convergent solutions and the results obtained are in good agreement with previous determinations in the literature. Based on observations made with the Nordic Optical Telescope, operated on the island of La Palma jointly by Denmark, Finland, Iceland, Norway, and Sweden, in the Spanish Observatorio del Roche de los Muchachos of the Instituto de Astrofisica de Canarias. Table 6 is only available in electronic form at http://www.edpsciences.org
Oxidation of As(III) to As(V) using ozone microbubbles.
Khuntia, Snigdha; Majumder, Subrata Kumar; Ghosh, Pallab
2014-02-01
The use of ozone in the treatment of water and wastewater is rapidly increasing due to its high oxidizing power. Arsenic is one the most toxic elements found in water. As(III) and As(V) are the major sources of arsenic poisoning. It is known that As(V) can be more easily removed from water by adsorptive methods than As(III). In this work, oxidation of more toxic As(III) to less toxic As(V) was studied in a pilot-plant by using ozone microbubbles. The microbubbles were effective in dissolving ozone in water. The oxidation was fast over a wide range of pH (e.g., 4-9). The role of hydroxyl radical in the oxidation of As(III) under acidic conditions was investigated by using 2-propanol as the hydroxyl radical scavenger. Under acidic conditions, the addition of 2-propanol slowed down the oxidation, which proves that hydroxyl radicals were involved in the oxidation process. The effect of carbonate ions on the rate of oxidation was investigated. It was found that the generation of carbonate ion radical from the carbonate ion accelerated the oxidation of As(III). The kinetics of oxidation of As(III) by ozone was studied. Copyright © 2013 Elsevier Ltd. All rights reserved.
Early stage sustainability evaluation of new, nanoscale cathode materials for Li-ion batteries.
Hischier, Roland; Kwon, Nam Hee; Brog, Jean-Pierre; Fromm, Katharina M
2018-05-07
We present results of early stage sustainability evaluation of two development strategies for new, nano-scale cathode materials for Li-ion batteries: (i) a new production pathway of existing material (LiCoO2), and (ii) a new nanomaterial (LiMnPO4). Nano-LiCoO2 was synthesized via a single source precursor route at lower temperature with a shorter reaction time, resulting in a smaller grain size and, thereby, a better diffusivity for Li-ions. Nano-LiMnPO4 was synthesized via a wet chemical method. The sustainability potential of these materials has then been investigated (at the laboratory and pilot production scales). The results show that the environmental impact of nano-LiMnPO4 is lower compared to the other examined nanomaterial by several factors, and this regardless of the indicator for the comparison. In contrast to commercial cathode materials, this new material shows, particularly on an energy and capacity basis, results in the same order of magnitude as those of lithium manganese oxide (LiMn2O4), and only slightly higher values than those for lithium iron phosphate (LiFePO4); values that are clearly lower than those for high-temperature LiCoO2. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Pilot applications of electrochemical chloride extraction on concrete bridge decks in Virginia.
DOT National Transportation Integrated Search
1996-01-01
A recent SHRP study confirmed that applying an electrical field between the surface of a concrete structure and the rebars (like cathodic protection, except with 50 to 500 times more current) can expel the chloride ions from salt-contaminated reinfor...
ETV REPORT: AND STATEMENT: HYDROMATIX 786E ION EXCHANGE RINSEWATER RECYCLING SYSTEM
RPA's ETV Program, through the NRMRL, has partnered with the California Dept. of Toxic Substances Contol (DTSCO) under an ETV Pilot to verify pollution prevention, recycling, and waste treatment technologies. This report provides a verification of performance results for the Hydr...
STS-31 MS Sullivan and Pilot Bolden monitor SE 82-16 Ion Arc on OV-103 middeck
NASA Technical Reports Server (NTRS)
1990-01-01
STS-31 Mission Specialist (MS) Kathryn D. Sullivan monitors and advises ground controllers of the activity inside the Student Experiment (SE) 82-16, Ion arc - studies of the effects of microgravity and a magnetic field on an electric arc, mounted in front of the middeck lockers aboard Discovery, Orbiter Vehicle (OV) 103. Pilot Charles F. Bolden uses a video camera and an ARRIFLEX motion picture camera to record the activity inside the special chamber. A sign in front of the experiment reads 'SSIP 82-16 Greg's Experiment Happy Graduation from STS-31.' SSIP stands for Shuttle Student Involvement Program. Gregory S. Peterson who developed the experiment (Greg's Experiment) is a student at Utah State University and monitored the experiment's operation from JSC's Mission Control Center (MCC) during the flight. Decals displayed in the background on the orbiter galley represent the Hubble Space Telescope (HST), the United States (U.S.) Naval Reserve, Navy Oceanographers, U.S. Navy, and Univer
Single-crystal and polycrystalline diamond erosion studies in Pilot-PSI
NASA Astrophysics Data System (ADS)
Kogut, D.; Aussems, D.; Ning, N.; Bystrov, K.; Gicquel, A.; Achard, J.; Brinza, O.; Addab, Y.; Martin, C.; Pardanaud, C.; Khrapak, S.; Cartry, G.
2018-03-01
Diamond is a promising candidate for enhancing the negative-ion surface production in the ion sources for neutral injection in fusion reactors; hence evaluation of its reactivity towards hydrogen plasma is of high importance. Single crystal and polycrystalline diamond samples were exposed in Pilot-PSI with the D+ flux of (4‒7)·1024 m-2s-1 and the impact energy of 7-9 eV per deuteron at different surface temperatures; under such conditions physical sputtering is negligible, however chemical sputtering is important. Net chemical sputtering yield Y = 9.7·10-3 at/ion at 800 °C was precisely measured ex-situ using a protective platinum mask (5 × 10 × 2 μm) deposited beforehand on a single crystal followed by the post-mortem analysis using Transmission Electron Microscopy (TEM). The structural properties of the exposed diamond surface were analyzed by Raman spectroscopy and X-ray Photoelectron Spectroscopy (XPS). Gross chemical sputtering yields were determined in-situ by means of optical emission spectroscopy of the molecular CH A-X band for several surface temperatures. A bell-shaped dependence of the erosion yield versus temperature between 400 °C and 1200 °C was observed, with a maximum yield of ∼1.5·10-2 at/ion attained at 900 °C. The yields obtained for diamond are relatively high (0.5-1.5)·10-2 at/ion, comparable with those of graphite. XPS analysis shows amorphization of diamond surface within 1 nm depth, in a good agreement with molecular dynamics (MD) simulation. MD was also applied to study the hydrogen impact energy threshold for erosion of [100] diamond surface at different temperatures.
Bench-Scale and Pilot-Scale Treatment Technologies for the ...
Coal mine water (CMW) is typically treated to remove suspended solids, acidity, and soluble metals, but high concentrations of total dissolved solids (TDS) have been reported to impact the environment at several CMW discharge points. Consequently, various states have established TDS wastewater regulations and the US EPA has proposed a benchmark conductivity limit to reduce TDS impacts in streams near mining sites. Traditional CMW treatment effectively removes some TDS components, but is not effective in removing major salt ions due to their higher solubility. This paper describes the basic principles, effectiveness, advantages and disadvantages of various TDS removal technologies (adsorption, bioremediation, capacitive deionization, desalination, electro-chemical ion exchange, electrocoagulation, electrodialysis, ion exchange, membrane filtration, precipitation, and reverse osmosis) that have at least been tested in bench- and pilot-scale experiments. Recent discussions about new regulations to include total dissolved solids TDS) limits would propel interest in the TDS removal technologies focused on coal mine water. TDS removal is not a new concept and has been developed using different technologies for a number of applications, but coal mine water has unique characteristics (depending on the site, mining process, and solid-water-oxygen interactions), which make it unlikely to have a single technology predominating over others. What are some novel technolog
[Information value of "additional tasks" method to evaluate pilot's work load].
Gorbunov, V V
2005-01-01
"Additional task" method was used to evaluate pilot's work load in prolonged flight. Calculated through durations of latent periods of motor responses, quantitative criterion of work load is more informative for objective evaluation of pilot's involvement in his piloting functions rather than of other registered parameters.
NASA Astrophysics Data System (ADS)
Lapierre, A.; Bollen, G.; Crisp, D.; Krause, S. W.; Linhardt, L. E.; Lund, K.; Nash, S.; Rencsok, R.; Ringle, R.; Schwarz, S.; Steiner, M.; Sumithrarachchi, C.; Summers, T.; Villari, A. C. C.; Williams, S. J.; Zhao, Q.
2018-05-01
The electron-beam ion trap (EBIT) charge breeder of the ReA post-accelerator, located at the National Superconducting Cyclotron Laboratory (Michigan State University), started on-line operation in September 2015. Since then, the EBIT has delivered many pilot beams of stable isotopes and several rare-isotope beams. An operating aspect of the ReA EBIT is the breeding of high charge states to reach high reaccelerated beam energies. Efficiencies in single charge states of more than 20% were measured with
Objective Versus Subjective Military Pilot Selection Methods in the United States of America
2015-12-14
a computerized test designed to assess pilot skills by measuring spatial orientation and psychomotor skills and multitasking . The second is the...AFRL-SA-WP-SR-2015-0028 Objective Versus Subjective Military Pilot Selection Methods in the United States of America Joe...September 2014 4. TITLE AND SUBTITLE Objective Versus Subjective Military Pilot Selection Methods in the United States of America 5a. CONTRACT
SITE - EMERGING TECHNOLOGY: REMOVAL AND RECOVERY OF METAL IONS FROM GROUNDWATER - APPENDICES
A series of laboratory tests and an on-site pilot scale demonstration of Bio-Recovery Systems' AlgaSORB technology for the removal and recovery of mercury-contaminated groundwater were conducted under the SITE program. ptimum conditions were determined for mercury binding to Alga...
Covariance Matrix Estimation for Massive MIMO
NASA Astrophysics Data System (ADS)
Upadhya, Karthik; Vorobyov, Sergiy A.
2018-04-01
We propose a novel pilot structure for covariance matrix estimation in massive multiple-input multiple-output (MIMO) systems in which each user transmits two pilot sequences, with the second pilot sequence multiplied by a random phase-shift. The covariance matrix of a particular user is obtained by computing the sample cross-correlation of the channel estimates obtained from the two pilot sequences. This approach relaxes the requirement that all the users transmit their uplink pilots over the same set of symbols. We derive expressions for the achievable rate and the mean-squared error of the covariance matrix estimate when the proposed method is used with staggered pilots. The performance of the proposed method is compared with existing methods through simulations.
Evaluation of Piloted Inputs for Onboard Frequency Response Estimation
NASA Technical Reports Server (NTRS)
Grauer, Jared A.; Martos, Borja
2013-01-01
Frequency response estimation results are presented using piloted inputs and a real-time estimation method recently developed for multisine inputs. A nonlinear simulation of the F-16 and a Piper Saratoga research aircraft were subjected to different piloted test inputs while the short period stabilator/elevator to pitch rate frequency response was estimated. Results show that the method can produce accurate results using wide-band piloted inputs instead of multisines. A new metric is introduced for evaluating which data points to include in the analysis and recommendations are provided for applying this method with piloted inputs.
Extraction of Structural Extracellular Polymeric Substances from Aerobic Granular Sludge
Felz, Simon; Al-Zuhairy, Salah; Aarstad, Olav Andreas; van Loosdrecht, Mark C.M.; Lin, Yue Mei
2016-01-01
To evaluate and develop methodologies for the extraction of gel-forming extracellular polymeric substances (EPS), EPS from aerobic granular sludge (AGS) was extracted using six different methods (centrifugation, sonication, ethylenediaminetetraacetic acid (EDTA), formamide with sodium hydroxide (NaOH), formaldehyde with NaOH and sodium carbonate (Na2CO3) with heat and constant mixing). AGS was collected from a pilot wastewater treatment reactor. The ionic gel-forming property of the extracted EPS of the six different extraction methods was tested with calcium ions (Ca2+). From the six extraction methods used, only the Na2CO3 extraction could solubilize the hydrogel matrix of AGS. The alginate-like extracellular polymers (ALE) recovered with this method formed ionic gel beads with Ca2+. The Ca2+-ALE beads were stable in EDTA, formamide with NaOH and formaldehyde with NaOH, indicating that ALE are one part of the structural polymers in EPS. It is recommended to use an extraction method that combines physical and chemical treatment to solubilize AGS and extract structural EPS. PMID:27768085
LEACHING OF METALS FROM HOUSEHOLD PLUMBING MATERIALS: IMPACT OF HOME WATER SOFTENERS
A pilot plant study was conducted to evaluate the effects of household ion exchange softening on the leaching of metals from home plumbing materials. The study was conducted in two phases on two different water qualities. Phase I was conducted using a finished tap water having a...
EMERGING TECHNOLOGY SUMMARY: REMOVAL AND RECOVERY OF METAL IONS FROM GROUNDWATER
A series of bench-scale tests and an onsite pilot scale demonstration of Bio-Recovery Systems' AlgaSORB® technology for the removal and recovery of mercury-contaminated groundwaters were conducted under the SITE program. The AlgaSORB® process is based on the natural, very st...
Jones, K.; Kim, K.; Patel, B.; Kelsen, S.; Braverman, A.; Swinton, D.; Gafken, P.; Jones, L.; Lane, W.; Neveu, J.; Leung, H.; Shaffer, S.; Leszyk, J.; Stanley, B.; Fox, T.; Stanley, A.; Yeung, Anthony
2013-01-01
Proteomic research can benefit from simultaneous access to multiple cutting-edge mass spectrometers. 18 core facilities responded to our investigators seeking service through the ABRF Discussion Forum. Five of the facilities selected completed four plasma proteomics experiments as routine fee-for-service. Each biological experiment entailed an iTRAQ 4-plex proteome comparison of immunodepleted plasma provided as 30 labeled-peptide fractions. Identical samples were analyzed by two AB SCIEX TripleTOF 5600 and three Thermo Orbitrap (Elite/Velos Pro/Q Exactive) instruments. 480 LC-MS/MS runs delivered >250 GB of data over two months. We compare herein routine service analyses of three peptide fractions of different peptide abundance. Data files from each instrument were studied to develop optimal analysis parameters to compare with default parameters in Mascot Distiller 2.4, ProteinPilot 4.5 beta, AB Sciex MS Data Converter 1.3 beta, and Proteome Discover 1.3. Peak-picking for TripleTOFs was best by ProteinPilot 4.5 beta while Mascot Distiller and Proteome Discoverer were comparable for the Orbitraps. We compared protein identification and quantitation in SwissProt 2012_07 database by Mascot Server 2.4.01 versus ProteinPilot. By all search methods, more proteins, up to two fold, were identified using the Q Exactive than others. Q Exactive excelled also at the number of unique significant peptide ion sequences. However, software-dependent impact on subsequent interpretation, due to peptide modifications, can be critical. These findings may have special implications for iTRAQ plasma proteomics. For the low abundance peptide ions, the slope of the dynamic range drop-off in the plasma proteome is uniquely sharp compared with cell lysates. Our study provides data for testable improvements in the operation of these mass spectrometers. More importantly, we have demonstrated a new affordable expedient workflow for investigators to perform proteomic experiments through the ABRF infrastructure. (We acknowledge John Cottrell for optimizing the peak-picking parameters for Mascot Distiller).
Saran, Sarangapany; Arunkumar, Patchaiyappan; Manjari, Gangarapu; Devipriya, Suja P
2018-05-05
Application of pilot-scale slurry-type tubular photocatalytic reactor was tested for the decentralized treatment of actual grey water. The reactors were fabricated by reusing the locally available materials at low cost, operated in batch recycle mode with 25 L of grey water. The influence of operational parameters such as catalysts' concentration, initial slurry pH and addition of H 2 O 2 on COD abatement were optimized. The results show that Ag-decorated TiO 2 showed a two-fold increase in COD abatement than did pure TiO 2 . Better COD abatement was observed under acidic conditions, and addition of H 2 O 2 significantly increases the rate of COD abatement. Within 2 h, 99% COD abatement was observed when the reactor was operated with optimum operational conditions. Silver ion lixiviate was also monitored during the experiment and is five times less than the permissible limits. The catalyst shows good stability even after five cycles without much loss in its photocatalytic activity. The results clearly reveal that pilot-scale slurry tubular solar photocatalytic reactors could be used as a cost-effective method to treat grey water and the resulting clean water could be reused for various non-potable purposes, thus conserving precious water resource. This study favours decentralized grey water treatment and possible scaling up of solar photocatalytic reactor using locally available materials for the potential reuse of treated water.
Patel, N; Alkhouri, N; Eng, K; Cikach, F; Mahajan, L; Yan, C; Grove, D; Rome, E S; Lopez, R; Dweik, R A
2014-09-01
Breath testing is becoming an important diagnostic method to evaluate many disease states. In the light of rising healthcare costs, is important to develop a simple non-invasive tool to potentially identify paediatric patients who need endoscopy for suspected inflammatory bowel disease (IBD). To analyse exhaled volatile organic compounds (VOCs) and investigate the presence of a unique breath patterns to differentiate paediatric patients with (IBD) from healthy controls. A cross-sectional, single-centre study included paediatric IBD patients and healthy controls (age range, 5-21 years). The diagnosis of IBD was confirmed by endoscopic, histological and radiographic data. Exhaled breath was collected and analysed using a selective ion flow tube mass spectroscopy (SIFT-MS) to identify new markers or patterns of IBD. One hundred and seventeen patients (62 with IBD and 55 healthy controls) were included in the study. Linear discriminant analysis and principle component analysis of mass scanning ion peak data demonstrated 21 pre-selected VOCs correctly classify patients with IBD or as healthy controls; P < 0.0001. Multivariable logistic regression analysis further showed three specific VOCs (1-octene, 1-decene, (E)-2-nonene) had excellent accuracy for predicting the presence of IBD with an area under the curve (AUC) of 0.96 (95% CI: 0.93-0.99). No significant difference in VOCs was found between patients with Crohn's disease or ulcerative colitis, and no significant correlation was seen with disease activity. These pilot data support the hypothesis that a unique breathprint potentially exists for paediatric IBD in the exhaled metabolome. © 2014 John Wiley & Sons Ltd.
Tippkötter, Nils; Roikaew, Wipa; Ulber, Roland; Hoffmann, Alexander; Denzler, Hans-Jörg; Buchholz, Heinrich
2010-01-01
Nitrate is an undesirable component of several foods. A typical case of contamination with high nitrate contents is whey concentrate, containing nitrate in concentrations up to 25 l. The microbiological removal of nitrate by Paracoccus denitrificans under formation of harmless nitrogen in combination with a cell retention reactor is described here. Focus lies on the resource-conserving design of a microbal denitrification process. Two methods are compared. The application of polyvinyl alcohol-immobilized cells, which can be applied several times in whey feed, is compared with the implementation of a two step denitrification system. First, the whey concentrate's nitrate is removed by ion exchange and subsequently the eluent regenerated by microorganisms under their retention by crossflow filtration. Nitrite and nitrate concentrations were determined by reflectometric color measurement with a commercially available Reflectoquant device. Correction factors for these media had to be determined. During the pilot development, bioreactors from 4 to 250 mg x L(-1) and crossflow units with membrane areas from 0.02 to 0.80 m(2) were examined. Based on the results of the pilot plants, a scaling for the exemplary process of denitrifying 1,000 tons per day is discussed. Copyright 2010 American Institute of Chemical Engineers
NASA Astrophysics Data System (ADS)
Klaas, Dua K. S. Y.; Imteaz, Monzur Alam
2017-09-01
A robust configuration of pilot points in the parameterisation step of a model is crucial to accurately obtain a satisfactory model performance. However, the recommendations provided by the majority of recent researchers on pilot-point use are considered somewhat impractical. In this study, a practical approach is proposed for using pilot-point properties (i.e. number, distance and distribution method) in the calibration step of a groundwater model. For the first time, the relative distance-area ratio ( d/ A) and head-zonation-based (HZB) method are introduced, to assign pilot points into the model domain by incorporating a user-friendly zone ratio. This study provides some insights into the trade-off between maximising and restricting the number of pilot points, and offers a relative basis for selecting the pilot-point properties and distribution method in the development of a physically based groundwater model. The grid-based (GB) method is found to perform comparably better than the HZB method in terms of model performance and computational time. When using the GB method, this study recommends a distance-area ratio of 0.05, a distance-x-grid length ratio ( d/ X grid) of 0.10, and a distance-y-grid length ratio ( d/ Y grid) of 0.20.
Many recent pilot tests have demonstrated the benefits and cost effectiveness of point-of-use treatment technologies as opposed to centralized wastewater treatment for all sizes of plating facilities. A 9-month case study at a small plating facility in Cincinnati, OH utilizing po...
EXPOSURE ASSESSMENT METHODS DEVELOPMENT PILOTS FOR THE NATIONAL CHILDREN'S STUDY
Accurate exposure classification tools are needed to link exposure with health effects. EPA began methods development pilot studies in 2000 to address general questions about exposures and outcome measures. Selected pilot studies are highlighted in this poster. The “Literature Re...
Pillai, Suja; Gopalan, Vinod; Lo, Chung Y; Liew, Victor; Smith, Robert A; Lam, Alfred King Y
2017-02-01
The goal of this pilot study was to develop a customized, cost-effective amplicon panel (Ampliseq) for target sequencing in a cohort of patients with sporadic phaeochromocytoma/paraganglioma. Phaeochromocytoma/paragangliomas from 25 patients were analysed by targeted next-generation sequencing approach using an Ion Torrent PGM instrument. Primers for 15 target genes (NF1, RET, VHL, SDHA, SDHB, SDHC, SDHD, SDHAF2, TMEM127, MAX, MEN1, KIF1Bβ, EPAS1, CDKN2 & PHD2) were designed using ion ampliseq designer. Ion Reporter software and Ingenuity® Variant Analysis™ software (www.ingenuity.com/variants) from Ingenuity Systems were used to analysis these results. Overall, 713 variants were identified. The variants identified from the Ion Reporter ranged from 64 to 161 per patient. Single nucleotide variants (SNV) were the most common. Further annotation with the help of Ingenuity variant analysis revealed 29 of these 713variants were deletions. Of these, six variants were non-pathogenic and four were likely to be pathogenic. The remaining 19 variants were of uncertain significance. The most frequently altered gene in the cohort was KIF1B followed by NF1. Novel KIF1B pathogenic variant c.3375+1G>A was identified. The mutation was noted in a patient with clinically confirmed neurofibromatosis. Chromosome 1 showed the presence of maximum number of variants. Use of targeted next-generation sequencing is a sensitive method for the detecting genetic changes in patients with phaeochromocytoma/paraganglioma. The precise detection of these genetic changes helps in understanding the pathogenesis of these tumours. Copyright © 2016 Elsevier Inc. All rights reserved.
Piloting a Process Maturity Model as an e-Learning Benchmarking Method
ERIC Educational Resources Information Center
Petch, Jim; Calverley, Gayle; Dexter, Hilary; Cappelli, Tim
2007-01-01
As part of a national e-learning benchmarking initiative of the UK Higher Education Academy, the University of Manchester is carrying out a pilot study of a method to benchmark e-learning in an institution. The pilot was designed to evaluate the operational viability of a method based on the e-Learning Maturity Model developed at the University of…
Dale, Sachie; Markovski, Jasmina; Hristovski, Kiril D
2016-09-01
This study explores the possibility of employing the Pore Surface Diffusion Model (PSDM) to predict the arsenic breakthrough curve of a packed bed system operated under continuous flow conditions with realistic groundwater, and consequently minimize the need to conduct pilot scale tests. To provide the nano-metal (hydr)oxide hybrid ion exchange media's performance in realistic water matrices without engaging in taxing pilot scale testing, the multi-point equilibrium batch sorption tests under pseudo-equilibrium conditions were performed; arsenate breakthrough curve of short bed column (SBC) was predicted by the PSDM in the continuous flow experiments; SBC tests were conducted under the same conditions to validate the model. The overlapping Freundlich isotherms suggested that the water matrix and competing ions did not have any denoting effect on sorption capacity of the media when the matrix was changed from arsenic-only model water to real groundwater. As expected, the PSDM provided a relatively good prediction of the breakthrough profile for arsenic-only model water limited by intraparticle mass transports. In contrast, the groundwater breakthrough curve demonstrated significantly faster intraparticle mass transport suggesting to a surface diffusion process, which occurs in parallel to the pore diffusion. A simple selection of DS=1/2 DP appears to be sufficient when describing the facilitated surface diffusion of arsenate inside metal (hydr)oxide nano-enabled hybrid ion-exchange media in presence of sulfate, however, quantification of the factors determining the surface diffusion coefficient's magnitude under different treatment scenarios remained unexplored. Copyright © 2015 Elsevier B.V. All rights reserved.
The application of the pilot points in groundwater numerical inversion model
NASA Astrophysics Data System (ADS)
Hu, Bin; Teng, Yanguo; Cheng, Lirong
2015-04-01
Numerical inversion simulation of groundwater has been widely applied in groundwater. Compared to traditional forward modeling, inversion model has more space to study. Zones and inversing modeling cell by cell are conventional methods. Pilot points is a method between them. The traditional inverse modeling method often uses software dividing the model into several zones with a few parameters needed to be inversed. However, distribution is usually too simple for modeler and result of simulation deviation. Inverse cell by cell will get the most actual parameter distribution in theory, but it need computational complexity greatly and quantity of survey data for geological statistical simulation areas. Compared to those methods, pilot points distribute a set of points throughout the different model domains for parameter estimation. Property values are assigned to model cells by Kriging to ensure geological units within the parameters of heterogeneity. It will reduce requirements of simulation area geological statistics and offset the gap between above methods. Pilot points can not only save calculation time, increase fitting degree, but also reduce instability of numerical model caused by numbers of parameters and other advantages. In this paper, we use pilot point in a field which structure formation heterogeneity and hydraulics parameter was unknown. We compare inversion modeling results of zones and pilot point methods. With the method of comparative analysis, we explore the characteristic of pilot point in groundwater inversion model. First, modeler generates an initial spatially correlated field given a geostatistical model by the description of the case site with the software named Groundwater Vistas 6. Defining Kriging to obtain the value of the field functions over the model domain on the basis of their values at measurement and pilot point locations (hydraulic conductivity), then we assign pilot points to the interpolated field which have been divided into 4 zones. And add range of disturbance values to inversion targets to calculate the value of hydraulic conductivity. Third, after inversion calculation (PEST), the interpolated field will minimize an objective function measuring the misfit between calculated and measured data. It's an optimization problem to find the optimum value of parameters. After the inversion modeling, the following major conclusion can be found out: (1) In a field structure formation is heterogeneity, the results of pilot point method is more real: better fitting result of parameters, more stable calculation of numerical simulation (stable residual distribution). Compared to zones, it is better of reflecting the heterogeneity of study field. (2) Pilot point method ensures that each parameter is sensitive and not entirely dependent on other parameters. Thus it guarantees the relative independence and authenticity of parameters evaluation results. However, it costs more time to calculate than zones. Key words: groundwater; pilot point; inverse model; heterogeneity; hydraulic conductivity
System and Method for Providing Model-Based Alerting of Spatial Disorientation to a Pilot
NASA Technical Reports Server (NTRS)
Johnson, Steve (Inventor); Conner, Kevin J (Inventor); Mathan, Santosh (Inventor)
2015-01-01
A system and method monitor aircraft state parameters, for example, aircraft movement and flight parameters, applies those inputs to a spatial disorientation model, and makes a prediction of when pilot may become spatially disoriented. Once the system predicts a potentially disoriented pilot, the sensitivity for alerting the pilot to conditions exceeding a threshold can be increased and allow for an earlier alert to mitigate the possibility of an incorrect control input.
Kovarikova, Petra; Pasakova-Vrbatova, Ivana; Vavrova, Anna; Stariat, Jan; Klimes, Jiri; Simunek, Tomas
2013-03-25
Dexrazoxane (DEX) is the only clinically used drug effective against anthracycline-induced cardiotoxicity and extravasation injury. However, the mechanism of its cardioprotective action still remains elusive. This paucity of comprehensive data is at least partially caused by the analytical difficulties associated with selective and sensitive simultaneous determination of the parent drug and its putative active metabolite ADR-925 in the relevant biological material. The aim of this study was to develop and validate the first LC-MS/MS method for simultaneous determination of DEX and ADR-925 in the isolated rat neonatal ventricular cardiomyocytes (NVCMs) and the cell culture medium. The analysis was performed on a Synergi Polar-RP column using the gradient profile of the mobile phase composed of 2mM ammonium formate and methanol. Electrospray ionization and ion trap mass analyzer were used as ionization and detection techniques, respectively. NVCMs were precipitated with methanol and the cell culture medium samples were diluted with the same solvent prior the LC-MS/MS analysis. The method was validated within the range of 4-80pmol/10(6) NVCMs and 7-70pmol/10(6) NVCMs for DEX and ADR-925, respectively, and at the concentrations of 8-100μM for both compounds in the culture cell medium. The practical applicability of this method was confirmed by the pilot analysis of NVCMs and the corresponding cell medium samples from relevant in vitro experiment. Hence, the LC-MS/MS method developed in this study represents a modern analytical tool suitable for investigation of DEX bioactivation inside the cardiomyocytes. In addition, the basic utility of the method for the analysis of DEX and ADR-925 in plasma samples was proved in a pilot experiment. Copyright © 2013 Elsevier B.V. All rights reserved.
Ion Implantation with in-situ Patterning for IBC Solar Cells
DOE Office of Scientific and Technical Information (OSTI.GOV)
Graff, John W.
2014-10-24
Interdigitated back-side Contact (IBC) solar cells are the highest efficiency silicon solar cells currently on the market. Unfortunately the cost to produce these solar cells is also very high, due to the large number of processing steps required. Varian believes that only the combination of high efficiency and low cost can meet the stated goal of $1/Wp. The core of this program has been to develop an in-situ patterning capability for an ion implantation system capable of producing patterned doped regions for IBC solar cells. Such a patterning capable ion implanter can reduce the number of process steps required tomore » manufacture IBC cells, and therefore significantly reduce the cost. The present program was organized into three phases. Phase I was to select a patterning approach and determine the patterning requirements for IBC cells. Phase II consists of construction of a Beta ion implantation system containing in-situ patterning capability. Phase III consists of shipping and installation of the ion implant system in a customer factory where it will be tested and proven in a pilot production line.« less
Flight directors for STOl aircraft
NASA Technical Reports Server (NTRS)
Rabin, U. H.
1983-01-01
Flight director logic for flight path and airspeed control of a powered-lift STOL aircraft in the approach, transition, and landing configurations are developed. The methods for flight director design are investigated. The first method is based on the Optimal Control Model (OCM) of the pilot. The second method, proposed here, uses a fixed dynamic model of the pilot in a state space formulation similar to that of the OCM, and includes a pilot work-load metric. Several design examples are presented with various aircraft, sensor, and control configurations. These examples show the strong impact of throttle effectiveness on the performance and pilot work-load associated with manual control of powered-lift aircraft during approach. Improved performed and reduced pilot work-load can be achieved by using direct-lift-control to increase throttle effectiveness.
NASA Technical Reports Server (NTRS)
Trujillo, Anna C.; Gregory, Irene M.
2014-01-01
Control-theoretic modeling of human operator's dynamic behavior in manual control tasks has a long, rich history. There has been significant work on techniques used to identify the pilot model of a given structure. This research attempts to go beyond pilot identification based on experimental data to develop a predictor of pilot behavior. Two methods for pre-dicting pilot stick input during changing aircraft dynamics and deducing changes in pilot behavior are presented This approach may also have the capability to detect a change in a subject due to workload, engagement, etc., or the effects of changes in vehicle dynamics on the pilot. With this ability to detect changes in piloting behavior, the possibility now exists to mediate human adverse behaviors, hardware failures, and software anomalies with autono-my that may ameliorate these undesirable effects. However, appropriate timing of when au-tonomy should assume control is dependent on criticality of actions to safety, sensitivity of methods to accurately detect these adverse changes, and effects of changes in levels of auto-mation of the system as a whole.
Effectiveness of methods for reducing acrylamide in bakery products.
Sadd, Peter A; Hamlet, Colin G; Liang, Li
2008-08-13
Pilot-scale bread, biscuit, and cracker doughs have been baked to assess how well recipe changes could reduce acrylamide in commercial bakery products. Removing ammonium-based raising agents was beneficial in biscuits. In doughs, long yeast fermentations were an effective way of reducing asparagine levels and hence acrylamide. At moderate fermentation times fructose levels increased, but the yeast later absorbed this, so the net effect on acrylamide was beneficial. Metal ions such as calcium reduced acrylamide when added as the carbonate or chloride. Hence, the fortification of flour with calcium carbonate, over and above its natural mineral content, has an additional benefit. However, some other possible methods of adding calcium to bakery doughs, for example, via the permitted preservative calcium propionate, were not beneficial. Amino acid addition to doughs gave modest reductions in acrylamide. Lowering the dough pH reduced acrylamide, but at the expense of higher levels of other process contaminants such as 3-monochloropropane-1,2-diol (3-MCPD).
Watkinson, D; Rimmer, M; Kasztovszky, Z; Kis, Z; Maróti, B; Szentmiklósi, L
2014-01-01
Chloride (Cl) ions diffuse into iron objects during burial and drive corrosion after excavation. Located under corrosion layers, Cl is inaccessible to many analytical techniques. Neutron analysis offers non-destructive avenues for determining Cl content and distribution in objects. A pilot study used prompt gamma activation analysis (PGAA) and prompt gamma activation imaging (PGAI) to analyse the bulk concentration and longitudinal distribution of Cl in archaeological iron objects. This correlated with the object corrosion rate measured by oxygen consumption, and compared well with Cl measurement using a specific ion meter. High-Cl areas were linked with visible damage to the corrosion layers and attack of the iron core. Neutron techniques have significant advantages in the analysis of archaeological metals, including penetration depth and low detection limits. PMID:26028670
Laboratory evaluation of a pilot cell battery protection system for photovoltaic applications
NASA Technical Reports Server (NTRS)
Cataldo, R. L.; Thomas, R. D.
1981-01-01
An energy storage method for the 3.5 kW battery power system was investigated. The Pilot Cell Battery Protection System was tested for use in photovoltaic power systems and results show that this is a viable method of storage battery control. The method of limiting battery depth of discharge has the following advantages: (1) temperature sensitivity; (2) rate sensitivity; and (3) state of charge indication. The pilot cell concept is of interest in remote stand alone photovoltaic power systems. The battery can be protected from damaging overdischarge by using the proper ratio of pilot cell capacities to main battery capacity.
Kim, Jae-Hyun; Kim, Song-Bae; Lee, Sang-Hyup; Choi, Jae-Woo
2018-03-01
The aim of this study was to apply iron oxide nanoparticle-chitosan (ION-chitosan) composites to phosphate removal from natural water collected from the Seoho Stream in Suwon, Republic of Korea. Laboratory batch experiments showed that phosphate removal by the ION-chitosan composites was not sensitive to pH changes between pH values of 5.0 and 9.0. During six cycles of adsorption-desorption, the composites could be successfully regenerated with 5 mM NaOH solution and reused for phosphate removal. Laboratory fixed-bed column experiments (column height = 10 and 20 cm, inner diameter = 2.5 cm, flow rate = 8.18 and 16.36 mL/min) demonstrated that the composites could be successfully applied for phosphate removal under dynamic flow conditions. A pilot-scale field experiment was performed in a pilot plant, which was mainly composed of chemical reactor/dissolved air flotation and an adsorption tower, built nearby the Seoho Stream. The natural water was pumped from the Seoho Stream into the pilot plant, passed through the chemical reactor/dissolved air flotation process, and then introduced into the adsorption tower (height = 100 cm, inner diameter = 45 cm, flow rate = 7.05 ± 0.18 L/min) for phosphate removal via the composites (composite volume = 80 L, composite weight = 85.74 kg). During monitoring of the adsorption tower (33 days), the influent total phosphorus (T-P) concentration was in the range of 0.020-0.046 mgP/L, whereas the effluent T-P concentration was in the range of 0.010-0.028 mgP/L. The percent removal of T-P in the adsorption tower was 52.3% with a phosphate removal capacity of 0.059 mgP/g.
NASA Astrophysics Data System (ADS)
Kachalin, G. V.; Mednikov, A. F.; Tkhabisimov, A. B.; Arkad'ev, D. A.; Temkin, S. G.; Senina, N. A.
2016-12-01
Fatigue test results of the rotating steel blades of the fourth stage of the K-25-0.6 low pressure cylinder Geo steam turbine manufactured in the Kaluga Turbine Plant (hereinafter, KTP) with the ion-plasma coating were presented. Coating formation was carried out at the National Research University (MPEI) on the Gefest vacuum pilot plant by the magnetron sputtering method. Characteristics of the obtained coating were analyzed with the use of the scientific-research equipment of the National Research University (MPEI). Fatigue tests of the rotating blades and determination of the fatigue strength of the material with the ion-plasma coating were carried out on the electrodynamic vibration machines VEDS-400A in the KTP structural laboratory. The following characteristics were obtained after tests: Ti-TiN composition, 10-11 μm thickness, 1200 HV 0.05 microhardness. Fatigue tests showed that destruction, regardless of availability or nonavailability of the coating, took place by cross-section in the root zone both on the leading and trailing edges of the blade, i.e., in the most stressed zones. It was found out that the maximum stresses during tests were revealed in the root section along the trailing edge on the blade pressure side, and the less stresses were on the leading edge. Fatigue strength of the working blades after coating formation increased by 12% minimum. Results of the fatigue tests prove the previously obtained data concerning 10-12% increase of the fatigue strength of the blade steel with the ion-plasma coating and allow claiming that the process of their formation exerts the positive influence on the fatigue characteristics of the blade materials.
75 FR 57275 - Information Collection; Supplier Greenhouse Gas Emissions Inventory Pilot
Federal Register 2010, 2011, 2012, 2013, 2014
2010-09-20
...] Information Collection; Supplier Greenhouse Gas Emissions Inventory Pilot AGENCY: Federal Acquisition Service... Greenhouse Gas (GHG) Emissions Inventory pilot. Public comments are particularly invited on: Whether this... 3090- 00XX; Supplier Greenhouse Gas Emissions Inventory Pilot, by any of the following methods...
Extraction of mercury from groundwater using immobilized algae.
Barkley, N P
1991-10-01
Bio-Recovery Systems, Inc. conducted a project under the Emerging Technology portion of the United States Environmental Protection Agency's (EPAs) Superfund Innovative Technology Evaluation (SITE) Program to evaluate the ability of immobilized algae to adsorb mercury from contaminated groundwater in laboratory studies and pilot-scale field tests. Algal biomass was incorporated in a permeable polymeric matrix. The product, AlgaSORB, packed into adsorption columns, exhibited excellent flow characteristics, and functioned as a "biological" ion exchange resin. A sequence of eleven laboratory tests demonstrated the ability of this product to adsorb mercury from groundwater that contained high levels of total dissolved solids and hard water components. However, use of a single AlgaSORB preparation yielded nonrepeatable results with samples collected at different times of the year. The strategy of sequentially extracting the groundwater through two columns containing different preparations of AlgaSORB was developed and proved successful in laboratory and pilot-scale field tests. Field test results indicate that AlgaSORB could be economically competitive with ion exchange resins for removal of mercury, with the advantage that hardness and other dissolved solids do not appear to compete with heavy metals for binding capacity.
Pilot-in-the-Loop CFD Method Development
2015-10-31
Contract # N00014-14-C-0020 Pilot-in-the-Loop CFD Method Development Progress Report (CDRL A001) Progress Report for Period: Aug 1, 2015 to...30-10-2015 4. TITLE AND SUBTITLE Pilot-in-the-Loop CFD Method Development 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6...environment. For example, ship airwake are calculated using CFD solutions without the presence of the helicopter main rotor. The gusts from the turbulent
NASA Astrophysics Data System (ADS)
Johnson, Ian D.; Blagovidova, Ekaterina; Dingwall, Paul A.; Brett, Dan J. L.; Shearing, Paul R.; Darr, Jawwad A.
2016-09-01
High power, phase-pure Nb-doped LiFePO4 (LFP) nanoparticles are synthesised using a pilot-scale continuous hydrothermal flow synthesis process (production rate of 6 kg per day) in the range 0.01-2.00 at% Nb with respect to total transition metal content. EDS analysis suggests that Nb is homogeneously distributed throughout the structure. The addition of fructose as a reagent in the hydrothermal flow process, followed by a post synthesis heat-treatment, affords a continuous graphitic carbon coating on the particle surfaces. Electrochemical testing reveals that cycling performance improves with increasing dopant concentration, up to a maximum of 1.0 at% Nb, for which point a specific capacity of 110 mAh g-1 is obtained at 10 C (6 min for the charge or discharge). This is an excellent result for a high power cathode LFP based material, particularly when considering the synthesis was performed on a large pilot-scale apparatus.
Pilot points method for conditioning multiple-point statistical facies simulation on flow data
NASA Astrophysics Data System (ADS)
Ma, Wei; Jafarpour, Behnam
2018-05-01
We propose a new pilot points method for conditioning discrete multiple-point statistical (MPS) facies simulation on dynamic flow data. While conditioning MPS simulation on static hard data is straightforward, their calibration against nonlinear flow data is nontrivial. The proposed method generates conditional models from a conceptual model of geologic connectivity, known as a training image (TI), by strategically placing and estimating pilot points. To place pilot points, a score map is generated based on three sources of information: (i) the uncertainty in facies distribution, (ii) the model response sensitivity information, and (iii) the observed flow data. Once the pilot points are placed, the facies values at these points are inferred from production data and then are used, along with available hard data at well locations, to simulate a new set of conditional facies realizations. While facies estimation at the pilot points can be performed using different inversion algorithms, in this study the ensemble smoother (ES) is adopted to update permeability maps from production data, which are then used to statistically infer facies types at the pilot point locations. The developed method combines the information in the flow data and the TI by using the former to infer facies values at selected locations away from the wells and the latter to ensure consistent facies structure and connectivity where away from measurement locations. Several numerical experiments are used to evaluate the performance of the developed method and to discuss its important properties.
NASA Astrophysics Data System (ADS)
Ma, W.; Jafarpour, B.
2017-12-01
We develop a new pilot points method for conditioning discrete multiple-point statistical (MPS) facies simulation on dynamic flow data. While conditioning MPS simulation on static hard data is straightforward, their calibration against nonlinear flow data is nontrivial. The proposed method generates conditional models from a conceptual model of geologic connectivity, known as a training image (TI), by strategically placing and estimating pilot points. To place pilot points, a score map is generated based on three sources of information:: (i) the uncertainty in facies distribution, (ii) the model response sensitivity information, and (iii) the observed flow data. Once the pilot points are placed, the facies values at these points are inferred from production data and are used, along with available hard data at well locations, to simulate a new set of conditional facies realizations. While facies estimation at the pilot points can be performed using different inversion algorithms, in this study the ensemble smoother (ES) and its multiple data assimilation variant (ES-MDA) are adopted to update permeability maps from production data, which are then used to statistically infer facies types at the pilot point locations. The developed method combines the information in the flow data and the TI by using the former to infer facies values at select locations away from the wells and the latter to ensure consistent facies structure and connectivity where away from measurement locations. Several numerical experiments are used to evaluate the performance of the developed method and to discuss its important properties.
27 CFR 19.31 - Pilot operations.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 27 Alcohol, Tobacco Products and Firearms 1 2011-04-01 2011-04-01 false Pilot operations. 19.31... Alternate Methods Or Procedures and Experimental Operations § 19.31 Pilot operations. Except for the filing... regulatory provision in this part for temporary pilot or experimental operations for the purpose of...
Handling qualities of large flexible control-configured aircraft
NASA Technical Reports Server (NTRS)
Swaim, R. L.
1979-01-01
The approach to an analytical study of flexible airplane longitudinal handling qualities was to parametrically vary the natural frequencies of two symmetric elastic modes to induce mode interactions with the rigid body dynamics. Since the structure of the pilot model was unknown for such dynamic interactions, the optimal control pilot modeling method is being applied and used in conjunction with pilot rating method.
NASA Astrophysics Data System (ADS)
Caloz, Misael; Kafrouni, Marilyne; Leturgie, Quentin; Corde, Stéphanie; Downes, Simon; Lehmann, Joerg; Thwaites, David
2015-01-01
There are few reported intercomparisons or audits of combinations of advanced radiotherapy methods, particularly for 4D treatments. As part of an evaluation of the implementation of advanced radiotherapy technology, a phantom and associated methods, initially developed for in-house commissioning and QA of 4D lung treatments, has been developed further with the aim of using it for end-to-end dose intercomparison of 4D treatment planning and delivery. The respiratory thorax phantom can house moving inserts with variable speed (breathing rate) and motion amplitude. In one set-up mode it contains a small ion chamber for point dose measurements, or alternatively it can hold strips of radiochromic film to measure dose distributions. Initial pilot and feasibility measurements have been carried out in one hospital to thoroughly test the methods and procedures before using it more widely across a range of hospitals and treatment systems. Overall, the results show good agreement between measured and calculated doses and distributions, supporting the use of the phantom and methodology for multi-centre intercomparisons. However, before wider use, refinements of the method and analysis are currently underway particularly for the film measurements.
Reviewing and piloting methods for decreasing discount rates; someone, somewhere in time.
Parouty, Mehraj B Y; Krooshof, Daan G M; Westra, Tjalke A; Pechlivanoglou, Petros; Postma, Maarten J
2013-08-01
There has been substantial debate on the need for decreasing discounting for monetary and health gains in economic evaluations. Next to the discussion on differential discounting, a way to identify the need for such discounting strategies is through eliciting the time preferences for monetary and health outcomes. In this article, the authors investigate the perceived time preference for money and health gains through a pilot survey on Dutch university students using methods on functional forms previously suggested. Formal objectives of the study were to review such existing methods and to pilot them on a convenience sample using a questionnaire designed for this specific purpose. Indeed, a negative relation between the time of delay and the variance of the discounting rate for all models was observed. This study was intended as a pilot for a large-scale population-based investigation using the findings from this pilot on wording of the questionnaire, interpretation, scope and analytic framework.
Preliminary Exploration of Adaptive State Predictor Based Human Operator Modeling
NASA Technical Reports Server (NTRS)
Trujillo, Anna C.; Gregory, Irene M.
2012-01-01
Control-theoretic modeling of the human operator dynamic behavior in manual control tasks has a long and rich history. In the last two decades, there has been a renewed interest in modeling the human operator. There has also been significant work on techniques used to identify the pilot model of a given structure. The purpose of this research is to attempt to go beyond pilot identification based on collected experimental data and to develop a predictor of pilot behavior. An experiment was conducted to quantify the effects of changing aircraft dynamics on an operator s ability to track a signal in order to eventually model a pilot adapting to changing aircraft dynamics. A gradient descent estimator and a least squares estimator with exponential forgetting used these data to predict pilot stick input. The results indicate that individual pilot characteristics and vehicle dynamics did not affect the accuracy of either estimator method to estimate pilot stick input. These methods also were able to predict pilot stick input during changing aircraft dynamics and they may have the capability to detect a change in a subject due to workload, engagement, etc., or the effects of changes in vehicle dynamics on the pilot.
Removal of copper ions from aqueous solutions by means of micellar-enhanced ultrafiltration
NASA Astrophysics Data System (ADS)
Kowalska, Izabela; Klimonda, Aleksandra
2017-11-01
The aim of the study was to assess the usefulness of micellar-enhanced ultrafiltration (MEUF) for removal of copper ions from water solutions in comparison with classic ultrafiltration process. The tests were conducted in a semi-pilot membrane installation with the use of ultrafiltration module KOCH/ROMICON® at a transmembrane pressure of 0.05 MPa. The effect of concentration of copper ions on ultrafiltration process efficiency was investigated. The second part of the tests concerned the removal of copper ions by MEUF under wide range of anionic surfactant concentration (0.25, 1, and 5 CMC (critical micelle concentration)). Concentration of copper ions in model solutions was equal to 5, 20, and 50 mg Cu/L. Furthermore, the effect of surfactant leakage to the permeate side during filtration was evaluated. Conducted experiments confirmed effectiveness of MEUF in copper ions removal. For the highest copper concentration in the feed (i.e. 50 mg/L), the average concentration of copper ions in the permeate ranged from 1.2-4.7 mg Cu/L depending on surfactant concentration. During filtration experiments, UF module exhibited stable transport properties for model solutions containing copper. For the highest concentration of metal, the decrease of permeate flux did not exceed 11% after 60 minutes of filtration. In the presence of the surfactant, a slight deterioration of transport properties was observed.
Extraction of steroidal glucosiduronic acids from aqueous solutions by anionic liquid ion-exchangers
Mattox, Vernon R.; Litwiller, Robert D.; Goodrich, June E.
1972-01-01
A pilot study on the extraction of three steroidal glucosiduronic acids from water into organic solutions of liquid ion-exchangers is reported. A single extraction of a 0.5mm aqueous solution of either 11-deoxycorticosterone 21-glucosiduronic acid or cortisone 21-glucosiduronic acid with 0.1m-tetraheptylammonium chloride in chloroform took more than 99% of the conjugate into the organic phase; under the same conditions, the very polar conjugate, β-cortol 3-glucosiduronic acid, was extracted to the extent of 43%. The presence of a small amount of chloride, acetate, or sulphate ion in the aqueous phase inhibited extraction, but making the aqueous phase 4.0m with ammonium sulphate promoted extraction strongly. An increase in the concentration of ion-exchanger in the organic phase also promoted extraction. The amount of cortisone 21-glucosiduronic acid extracted by tetraheptylammonium chloride over the pH range of 3.9 to 10.7 was essentially constant. Chloroform solutions of a tertiary, a secondary, or a primary amine hydrochloride also will extract cortisone 21-glucosiduronic acid from water. The various liquid ion exchangers will extract steroidal glucosiduronic acid methyl esters from water into chloroform, although less completely than the corresponding free acids. The extraction of the glucosiduronic acids from water by tetraheptylammonium chloride occurs by an ion-exchange process; extraction of the esters does not involve ion exchange. PMID:5075264
NASA Astrophysics Data System (ADS)
Lv, ZhuoKai; Yang, Tiejun; Zhu, Chunhua
2018-03-01
Through utilizing the technology of compressive sensing (CS), the channel estimation methods can achieve the purpose of reducing pilots and improving spectrum efficiency. The channel estimation and pilot design scheme are explored during the correspondence under the help of block-structured CS in massive MIMO systems. The block coherence property of the aggregate system matrix can be minimized so that the pilot design scheme based on stochastic search is proposed. Moreover, the block sparsity adaptive matching pursuit (BSAMP) algorithm under the common sparsity model is proposed so that the channel estimation can be caught precisely. Simulation results are to be proved the proposed design algorithm with superimposed pilots design and the BSAMP algorithm can provide better channel estimation than existing methods.
Pilot-optimal augmentation synthesis
NASA Technical Reports Server (NTRS)
Schmidt, D. K.
1978-01-01
An augmentation synthesis method usable in the absence of quantitative handling qualities specifications, and yet explicitly including design objectives based on pilot-rating concepts, is presented. The algorithm involves the unique approach of simultaneously solving for the stability augmentation system (SAS) gains, pilot equalization and pilot rating prediction via optimal control techniques. Simultaneous solution is required in this case since the pilot model (gains, etc.) depends upon the augmented plant dynamics, and the augmentation is obviously not a priori known. Another special feature is the use of the pilot's objective function (from which the pilot model evolves) to design the SAS.
Method for reduction of selected ion intensities in confined ion beams
Eiden, Gregory C.; Barinaga, Charles J.; Koppenaal, David W.
1998-01-01
A method for producing an ion beam having an increased proportion of analyte ions compared to carrier gas ions is disclosed. Specifically, the method has the step of addition of a charge transfer gas to the carrier analyte combination that accepts charge from the carrier gas ions yet minimally accepts charge from the analyte ions thereby selectively neutralizing the carrier gas ions. Also disclosed is the method as employed in various analytical instruments including an inductively coupled plasma mass spectrometer.
Method for reduction of selected ion intensities in confined ion beams
Eiden, G.C.; Barinaga, C.J.; Koppenaal, D.W.
1998-06-16
A method for producing an ion beam having an increased proportion of analyte ions compared to carrier gas ions is disclosed. Specifically, the method has the step of addition of a charge transfer gas to the carrier analyte combination that accepts charge from the carrier gas ions yet minimally accepts charge from the analyte ions thereby selectively neutralizing the carrier gas ions. Also disclosed is the method as employed in various analytical instruments including an inductively coupled plasma mass spectrometer. 7 figs.
FMP study of pilot workload. Qualification of workload via instrument scan
NASA Technical Reports Server (NTRS)
Tolel, J. R.; Vivaudou, M.; Harris, R. L., Sr.; Ephrath, A.
1982-01-01
Various methods of measuring a pilot's mental workload are discussed. Scanning the various flight instruments with good scan pattern and other verbal tasks during instrument landings is given special attention for measuring pilot workload.
Humbert, H; Machinal, C; Labaye, Ivan; Schrotter, J C
2011-01-01
The determination of the virus retention capabilities of UF units during operation is essential for the operators of drinking water treatment facilities in order to guarantee an efficient and stable removal of viruses through time. In previous studies, an effective method (MS2-phage challenge tests) was developed by the Water Research Center of Veolia Environnement for the measurement of the virus retention rates (Log Removal Rate, LRV) of commercially available hollow fiber membranes at lab scale. In the present work, the protocol for monitoring membrane performance was transferred from lab scale to pilot scale. Membrane performances were evaluated during pilot trial and compared to the results obtained at lab scale with fibers taken from the pilot plant modules. PFU culture method was compared to RT-PCR method for the calculation of LRV in both cases. Preliminary tests at lab scale showed that both methods can be used interchangeably. For tests conducted on virgin membrane, a good consistency was observed between lab and pilot scale results with the two analytical methods used. This work intends to show that a reliable determination of the membranes performances based on RT-PCR analytical method can be achieved during the operation of the UF units.
Adaptive State Predictor Based Human Operator Modeling on Longitudinal and Lateral Control
NASA Technical Reports Server (NTRS)
Trujillo, Anna C.; Gregory, Irene M.; Hempley, Lucas E.
2015-01-01
Control-theoretic modeling of the human operator dynamic behavior in manual control tasks has a long and rich history. In the last two decades, there has been a renewed interest in modeling the human operator. There has also been significant work on techniques used to identify the pilot model of a given structure. The purpose of this research is to attempt to go beyond pilot identification based on collected experimental data and to develop a predictor of pilot behavior. An experiment was conducted to categorize these interactions of the pilot with an adaptive controller compensating during control surface failures. A general linear in-parameter model structure is used to represent a pilot. Three different estimation methods are explored. A gradient descent estimator (GDE), a least squares estimator with exponential forgetting (LSEEF), and a least squares estimator with bounded gain forgetting (LSEBGF) used the experiment data to predict pilot stick input. Previous results have found that the GDE and LSEEF methods are fairly accurate in predicting longitudinal stick input from commanded pitch. This paper discusses the accuracy of each of the three methods - GDE, LSEEF, and LSEBGF - to predict both pilot longitudinal and lateral stick input from the flight director's commanded pitch and bank attitudes.
Variably Transmittive, Electronically-Controlled Eyewear
NASA Technical Reports Server (NTRS)
Chapman, John J. (Inventor); Glaab, Louis J. (Inventor); Schott, Timothy D. (Inventor); Howell, Charles T. (Inventor); Fleck, Vincent J. (Inventor)
2013-01-01
A system and method for flight training and evaluation of pilots comprises electronically activated vision restriction glasses that detect the pilot's head position and automatically darken and restrict the pilot's ability to see through the front and side windscreens when the pilot-in-training attempts to see out the windscreen. Thus, the pilot-in-training sees only within the aircraft cockpit, forcing him or her to fly by instruments in the most restricted operational mode.
HI and Low Metal Ions at the Intersection of Galaxies and the CGM
NASA Astrophysics Data System (ADS)
Oppenheimer, Benjamin
2017-08-01
Over 1000 COS orbits have revealed a surprisingly complex picture of circumgalactic gas flows surrounding the diversity of galaxies in the evolved Universe. Cosmological hydrodynamic simulations have only begun to confront the vast amount of galaxy formation physics, chemistry, and dynamics revealed in the multi-ion CGM datasets. We propose the next generation of EAGLE zoom simulations, called EAGLE Cosmic Origins, to model HI and low metal ions (C II, Mg II, & Si II) throughout not just the CGM but also within the galaxies themselves. We will employ a novel, new chemistry solver, CHIMES, to follow time-dependent ionization, chemistry, and cooling of 157 ionic and molecular species, and include multiple ionization sources from the extra-galactic background, episodic AGN, and star formation. Our aim is to understand the complete baryon cycle of inflows, outflows, and gas recycling traced over 10 decades of HI column densities as well as the complex kinematic information encoded low ion absorption spectroscopy. This simulation project represents a pilot program for a larger suite of zoom simulations, which will be publicly released and lead to additional publications.
Novel Estimation of Pilot Performance Characteristics
NASA Technical Reports Server (NTRS)
Bachelder, Edward N.; Aponso, Bimal
2017-01-01
Two mechanisms internal to the pilot that affect performance during a tracking task are: 1) Pilot equalization (i.e. lead/lag); and 2) Pilot gain (i.e. sensitivity to the error signal). For some applications McRuer's Crossover Model can be used to anticipate what equalization will be employed to control a vehicle's dynamics. McRuer also established approximate time delays associated with different types of equalization - the more cognitive processing that is required due to equalization difficulty, the larger the time delay. However, the Crossover Model does not predict what the pilot gain will be. A nonlinear pilot control technique, observed and coined by the authors as 'amplitude clipping', is shown to improve stability, performance, and reduce workload when employed with vehicle dynamics that require high lead compensation by the pilot. Combining linear and nonlinear methods a novel approach is used to measure the pilot control parameters when amplitude clipping is present, allowing precise measurement in real time of key pilot control parameters. Based on the results of an experiment which was designed to probe workload primary drivers, a method is developed that estimates pilot spare capacity from readily observable measures and is tested for generality using multi-axis flight data. This paper documents the initial steps to developing a novel, simple objective metric for assessing pilot workload and its variation over time across a wide variety of tasks. Additionally, it offers a tangible, easily implementable methodology for anticipating a pilot's operating parameters and workload, and an effective design tool. The model shows promise in being able to precisely predict the actual pilot settings and workload, and observed tolerance of pilot parameter variation over the course of operation. Finally, an approach is proposed for generating Cooper-Harper ratings based on the workload and parameter estimation methodology.
75 FR 1591 - Green Technology Pilot Program
Federal Register 2010, 2011, 2012, 2013, 2014
2010-01-12
... DEPARTMENT OF COMMERCE Patent and Trademark Office Green Technology Pilot Program ACTION: Proposed... methods: E-mail: [email protected] . Include A0651-0062 Green Technology Pilot Program [email protected] in... green technologies, including greenhouse gas reduction. [[Page 1592
Ajaero, Chukwuemeka; Peru, Kerry M; Simair, Monique; Friesen, Vanessa; O'Sullivan, Gwen; Hughes, Sarah A; McMartin, Dena W; Headley, John V
2018-08-01
Large volumes of oil sands process-affected water (OSPW) are generated during the extraction of bitumen from oil sands in the Athabasca region of northeastern Alberta, Canada. As part of the development of treatment technologies, molecular characterization of naphthenic acids (NAs) and naphthenic acid fraction compounds (NAFC) in wetlands is a topic of research to better understand their fate and behavior in aquatic environments. Reported here is the application of high-resolution negative-ion electrospray Orbitrap-mass spectrometry for molecular characterization of NAs and NAFCs in a non-aerated constructed treatment wetland. The effectiveness of the wetlands to remove OSPW-NAs and NAFCs was evaluated by monitoring the changes in distributions of NAFC compounds in the untreated sample and non-aerated treatment system. After correction for measured evapotranspiration, the removal rate of the classical NAs followed approximately first-order kinetics, with higher rates observed for structures with relatively higher number of carbon atoms. These findings indicate that constructed wetland treatment is a viable method for removal of classical NAs in OSPW. Work is underway to evaluate the effects of wetland design on water quality improvement, preferential removal of different NAFC species, and reduction in toxicity. Copyright © 2018. Published by Elsevier B.V.
Distributed ignition method and apparatus for a combustion engine
Willi, Martin L.; Bailey, Brett M.; Fiveland, Scott B.; Gong, Weidong
2006-03-07
A method and apparatus for operating an internal combustion engine is provided. The method comprises the steps of introducing a primary fuel into a main combustion chamber of the engine, introducing a pilot fuel into the main combustion chamber of the engine, determining an operating load of the engine, determining a desired spark plug ignition timing based on the engine operating load, and igniting the primary fuel and pilot fuel with a spark plug at the desired spark plug ignition timing. The method is characterized in that the octane number of the pilot fuel is lower than the octane number of the primary fuel.
Talaeipour, M; Nouri, J; Hassani, A H; Mahvi, A H
2017-01-01
As an appropriate tool, membrane process is used for desalination of brackish water, in the production of drinking water. The present study aims to investigate desalination processes of brackish water of Qom Province in Iran. This study was carried out at the central laboratory of Water and Wastewater Company of the studied area. To this aim, membrane processes, including nanofiltration (NF) and reverse osmosis (RO), separately and also their hybrid process were applied. Moreover, water physical and chemical parameters, including salinity, total dissolved solids (TDS), electric conductivity (EC), Na +1 and Cl -1 were also measured. Afterward, the rejection percent of each parameter was investigated and compared using nanofiltration and reverse osmosis separately and also by their hybrid process. The treatment process was performed by Luna domestic desalination device, which its membrane was replaced by two NF90 and TW30 membranes for nanofiltration and reverse osmosis processes, respectively. All collected brackish water samples were fed through membranes NF90-2540, TW30-1821-100(RO) and Hybrid (NF/RO) which were installed on desalination household scale pilot (Luna water 100GPD). Then, to study the effects of pressure on permeable quality of membranes, the simulation software model ROSA was applied. Results showed that percent of the salinity rejection was recorded as 50.21%; 72.82 and 78.56% in NF, RO and hybrid processes, respectively. During the study, in order to simulate the performance of nanofiltartion, reverse osmosis and hybrid by pressure drive, reverse osmosis system analysis (ROSA) model was applied. The experiments were conducted at performance three methods of desalination to remove physic-chemical parameters as percentage of rejections in the pilot plant are: in the NF system the salinity 50.21, TDS 43.41, EC 43.62, Cl 21.1, Na 36.15, and in the RO membrane the salinity 72.02, TDS 60.26, EC 60.33, Cl 43.08, Na 54.41. Also in case of the rejection in hybrid system of those parameters and ions included salinity 78.65, TDS 76.52, EC 76.42, Cl 63.95, and Na 70.91. Comparing rejection percent in three above-mentioned methods, it could be concluded that, in reverse osmosis process, ions and non-ion parameters rejection ability were rather better than nanofiltration process, and also better in hybrid compared to reverse osmosis process. The results reported in this paper indicate that the integration of membrane nanofiltration with reverse osmosis (hybrid NF/RO) can be completed by each other probably to remove salinity, TDS, EC, Cl, and Na.
Evaluation of Control Inputs on the Spin Recovery of the 8KCAB Super Decathlon
2015-09-17
limited exposure to spins and variations of spin recovery methods. Aircraft spins have become taboo and avoided by all but the most experienced...knowledge of every pilot, some areas have become taboo and avoided all but the most experienced pilots and researchers. This leads to much...recovery methods. Aircraft spins have become taboo and avoided by all but the most experienced pilots and researchers. The research here is focused
2013-09-09
multivariate correction method (Lawley, 1943) was used for all scores except the MAB FSIQ which used the univariate ( Thorndike , 1949) method. FSIQ... Thorndike , R. L. (1949). Personnel selection. NY: Wiley. Tupes, E. C., & Christal, R. C. (1961). Recurrent personality factors based on trait ratings... Thorndike , 1949). aThe correlations for 1995 were not corrected due to the small sample size (N = 17). *p< .05 Consistency of Pilot Attributes
Reconstructing Cell Lineages from Single-Cell Gene Expression Data: A Pilot Study
2016-08-30
Reconstructing cell lineages from single- cell gene expression data: a pilot study The goal of this pilot study is to develop novel mathematical...methods, by leveraging tools developed in the bifurcation theory, to infer the underlying cell -state dynamics from single- cell gene expression data. Our...proposed method contains two steps. The first step is to reconstruct the temporal order of the cells from gene expression data, whereas the second
Effects of alcohol on pilot performance in simulated flight
NASA Technical Reports Server (NTRS)
Billings, C. E.; Demosthenes, T.; White, T. R.; O'Hara, D. B.
1991-01-01
Ethyl alcohol's known ability to produce reliable decrements in pilot performance was used in a study designed to evaluate objective methods for assessing pilot performance. Four air carrier pilot volunteers were studied during eight simulated flights in a B727 simulator. Total errors increased linearly and significantly with increasing blood alcohol. Planning and performance errors, procedural errors and failures of vigilance each increased significantly in one or more pilots and in the group as a whole.
Verification of Production Hole Quality. Volume 2
1977-11-01
Angular Position Axial Posi t ion Bottom #1 n_ gji #5 0° 7>0 LL± ^5° 90° -2,0 2,0 2X 180° 4jl_ MJ2- 225" ML iJ2 270° a*. 311 £.0...2 CenterdrMI; igM in. pilot drill; Group 1, Omark Drill Reamer (TLD20’»OARl-5) Spindle, rpm .^ gJI Feed: MAA/D - C.S
Pilot-Scale Test of Counter-Current Ion Exchange (CCIX) Using UOP IONSIV IE-911
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wester, Dennis W; Leugemors, Robert K; Taylor, Paul W
2001-09-24
A pilot-scale test of a moving-bed configuration of a UOP IONSIV? IE-911 ion-exchange column was performed over 17 days at Severn Trent Services facilities. The objectives of the test, in order of priority, were to determine if aluminosilicate precipitation caused clumping of IE-911 particles in the column, to observe the effect on aluminum-hydroxide precipitation of water added to a simulant-filled column, to evaluate the extent of particle attrition, and to measure the expansion of the mass-transfer zone under the influence of column pulsing. The IE-911 moved through the column with no apparent clumping during the test, although analytical results indicatemore » that little if any aluminosilicate precipitated onto the particles. A precipitate of aluminum hydroxide was not produced when water was added to the simulant-filled column, indicating that this upset scenario is probably of little concern. Particle-size distributions remained relatively constant with time and position in the column, indicating that particle attrition was not significant. The expansion of the mass-transfer zone could not be accurately measured because of the slow loading kinetics of the IE-911 and the short duration of the test; however, the information obtained indicates that back-mixing of sorbent is not extensive.« less
Covington, James A.; Wedlake, Linda; Andreyev, Jervoise; Ouaret, Nathalie; Thomas, Matthew G.; Nwokolo, Chuka U.; Bardhan, Karna D.; Arasaradnam, Ramesh P.
2012-01-01
It is well known that the electronic nose can be used to identify differences between human health and disease for a range of disorders. We present a pilot study to investigate if the electronic nose and a newer technology, FAIMS (Field Asymmetric Ion Mobility Spectrometry), can be used to identify and help inform the treatment pathway for patients receiving pelvic radiotherapy, which frequently causes gastrointestinal side-effects, severe in some. From a larger group, 23 radiotherapy patients were selected where half had the highest levels of toxicity and the others the lowest. Stool samples were obtained before and four weeks after radiotherapy and the volatiles and gases emitted analysed by both methods; these chemicals are products of fermentation caused by gut microflora. Principal component analysis of the electronic nose data and wavelet transform followed by Fisher discriminant analysis of FAIMS data indicated that it was possible to separate patients after treatment by their toxicity levels. More interestingly, differences were also identified in their pre-treatment samples. We believe these patterns arise from differences in gut microflora where some combinations of bacteria result to give this olfactory signature. In the future our approach may result in a technique that will help identify patients at “high risk” even before radiation treatment is started. PMID:23201982
Method and apparatus for efficient photodetachment and purification of negative ion beams
Beene, James R [Oak Ridge, TN; Liu, Yuan [Knoxville, TN; Havener, Charles C [Knoxville, TN
2008-02-26
Methods and apparatus are described for efficient photodetachment and purification of negative ion beams. A method of purifying an ion beam includes: inputting the ion beam into a gas-filled multipole ion guide, the ion beam including a plurality of ions; increasing a laser-ion interaction time by collisional cooling the plurality of ions using the gas-filled multipole ion guide, the plurality of ions including at least one contaminant; and suppressing the at least one contaminant by selectively removing the at least one contaminant from the ion beam by electron photodetaching at least a portion of the at least one contaminant using a laser beam.
Swendeman, Dallas; Jana, Smarajit; Ray, Protim; Mindry, Deborah; Das, Madhushree; Bhakta, Bhumi
2015-01-01
This two-phase pilot study aimed to design, pilot, and refine an automated Interactive Voice Response (IVR) intervention to support antiretroviral adherence for people living with HIV (PLH), in Kolkata, India. Mixed-methods formative research included a community advisory board (CAB) for IVR message development, one-month pre-post pilot, post-pilot focus groups, and further message development. Two IVR calls are made daily, timed to patients’ dosing schedules, with brief messages (<1-minute) on strategies for self-management of three domains: medical (adherence, symptoms, co-infections), mental health (social support, stress, positive cognitions), and nutrition and hygiene (per PLH preferences). Three ART appointment reminders are also sent each month. One-month pilot results (n=46, 80% women, 60% sex workers) found significant increases in self-reported ART adherence, both within past three days (p=0.05) and time since missed last dose (p=0.015). Depression was common. Messaging content and assessment domains were expanded for testing in a randomized trial is currently underway. PMID:25638037
Swendeman, Dallas; Jana, Smarajit; Ray, Protim; Mindry, Deborah; Das, Madhushree; Bhakta, Bhumi
2015-06-01
This two-phase pilot study aimed to design, pilot, and refine an automated interactive voice response (IVR) intervention to support antiretroviral adherence for people living with HIV (PLH), in Kolkata, India. Mixed-methods formative research included a community advisory board for IVR message development, 1-month pre-post pilot, post-pilot focus groups, and further message development. Two IVR calls are made daily, timed to patients' dosing schedules, with brief messages (<1-min) on strategies for self-management of three domains: medical (adherence, symptoms, co-infections), mental health (social support, stress, positive cognitions), and nutrition and hygiene (per PLH preferences). Three ART appointment reminders are also sent each month. One-month pilot results (n = 46, 80 % women, 60 % sex workers) found significant increases in self-reported ART adherence, both within past three days (p = 0.05) and time since missed last dose (p = 0.015). Depression was common. Messaging content and assessment domains were expanded for testing in a randomized trial currently underway.
Impact parameter sensitive study of inner-shell atomic processes in the experimental storage ring
NASA Astrophysics Data System (ADS)
Gumberidze, A.; Kozhuharov, C.; Zhang, R. T.; Trotsenko, S.; Kozhedub, Y. S.; DuBois, R. D.; Beyer, H. F.; Blumenhagen, K.-H.; Brandau, C.; Bräuning-Demian, A.; Chen, W.; Forstner, O.; Gao, B.; Gassner, T.; Grisenti, R. E.; Hagmann, S.; Hillenbrand, P.-M.; Indelicato, P.; Kumar, A.; Lestinsky, M.; Litvinov, Yu. A.; Petridis, N.; Schury, D.; Spillmann, U.; Trageser, C.; Trassinelli, M.; Tu, X.; Stöhlker, Th.
2017-10-01
In this work, we present a pilot experiment in the experimental storage ring (ESR) at GSI devoted to impact parameter sensitive studies of inner shell atomic processes for low-energy (heavy-) ion-atom collisions. The experiment was performed with bare and He-like xenon ions (Xe54+, Xe52+) colliding with neutral xenon gas atoms, resulting in a symmetric collision system. This choice of the projectile charge states was made in order to compare the effect of a filled K-shell with the empty one. The projectile and target X-rays have been measured at different observation angles for all impact parameters as well as for the impact parameter range of ∼35-70 fm.
Berberidou, Chrysanthi; Kitsiou, Vasiliki; Lambropoulou, Dimitra A; Antoniadis, Αpostolos; Ntonou, Eleftheria; Zalidis, George C; Poulios, Ioannis
2017-06-15
The present study proposes an integrated system based on the synergetic action of solar photocatalytic oxidation with surface flow constructed wetlands for the purification of wastewater contaminated with pesticides. Experiments were conducted at pilot scale using simulated wastewater containing the herbicide clopyralid. Three photocatalytic methods under solar light were investigated: the photo-Fenton and the ferrioxalate reagent as well as the combination of photo-Fenton with TiO 2 P25, which all led to similar mineralization rates. The subsequent treatment in constructed wetlands resulted in further decrease of DOC and inorganic ions concentrations, especially of NO 3 - . Clopyralid was absent in the outlet of the wetlands, while the concentration of the detected intermediates was remarkably low. These findings are in good agreement with the results of phytotoxicity of the wastewater, after treatment with the ferrioxalate/wetlands process, which was significantly reduced. Thus, this integrated system based on solar photocatalysis and constructed wetlands has the potential to effectively detoxify wastewater containing pesticides, producing a purified effluent which could be exploited for reuse applications. Copyright © 2016 Elsevier Ltd. All rights reserved.
Models of Pilot Behavior and Their Use to Evaluate the State of Pilot Training
NASA Astrophysics Data System (ADS)
Jirgl, Miroslav; Jalovecky, Rudolf; Bradac, Zdenek
2016-07-01
This article discusses the possibilities of obtaining new information related to human behavior, namely the changes or progressive development of pilots' abilities during training. The main assumption is that a pilot's ability can be evaluated based on a corresponding behavioral model whose parameters are estimated using mathematical identification procedures. The mean values of the identified parameters are obtained via statistical methods. These parameters are then monitored and their changes evaluated. In this context, the paper introduces and examines relevant mathematical models of human (pilot) behavior, the pilot-aircraft interaction, and an example of the mathematical analysis.
Instrumental Landing Using Audio Indication
NASA Astrophysics Data System (ADS)
Burlak, E. A.; Nabatchikov, A. M.; Korsun, O. N.
2018-02-01
The paper proposes an audio indication method for presenting to a pilot the information regarding the relative positions of an aircraft in the tasks of precision piloting. The implementation of the method is presented, the use of such parameters of audio signal as loudness, frequency and modulation are discussed. To confirm the operability of the audio indication channel the experiments using modern aircraft simulation facility were carried out. The simulated performed the instrument landing using the proposed audio method to indicate the aircraft deviations in relation to the slide path. The results proved compatible with the simulated instrumental landings using the traditional glidescope pointers. It inspires to develop the method in order to solve other precision piloting tasks.
NASA Astrophysics Data System (ADS)
Kammel, H.; Haase, H.
An experimental psycho-physiological method is presented for the evaluation of visual-cognitive performance preconditions and operational reliability of pilots and cosmonauts. As visual-cognitive stress are used tachistoscopically presented instrument symbols under conditions of individual speed of work and time pressure. The results of the compared extreme groups consisting of pilots with good and insufficient flight performance showed that the pilots with impairments to the quality of flight activity differ already before the test in their individual habitual characteristics and actual motivation, during the stress in their operational parameters, in the dimensions of their cardiorespiratory activation as well as in their efficiency and after the stress in their subjective experience of the stress. Conclusions are drawn for the evaluation of the aptitude of pilots and cosmonauts.
PILOT STUDY: THE TAMPA ASTHMATIC CHILDREN'S STUDY (TACS)
The Tampa Asthmatic Children's Study (TACS) was a pilot research study that focused on developing and evaluating air pollution exposure assessment methods and participant recruiting tools for children in the age range of 1-5 years old. The pilot study focused on (a) simple, cost-...
[ROLE OF THE SYMPATHOADRENOMEDULLARY SYSTEM IN FORMATION OF PILOT'S ADAPTATION TO FLIGHT LOADS].
Sukhoterin, A F; Pashchenko, P S; Plakhov, N N; Zhuravlev, A G
2015-01-01
Purpose of the work was to evaluate the sympathoadrenomedullary functions and associated psychophysiological reactions of pilots as a function of flight hours on highly maneuverable aircraft. Volunteers to the investigation were 78 pilots (41 pilots of maneuverable aircraft and 37 pilots of bombers and transporters). Selected methods were to enable comprehensive evaluation of the body functioning against flight loads. Our results evidence that piloting of high maneuverable aircraft but not of bombing and transporting aircrafts activates the sympathoadrenomedullary system significantly. This is particularly common to young pilots with the total flying time less than 1000 hours. Adaptive changes to flight factors were noted to develop with age and experience.
Recent developments on ion-exchange membranes and electro-membrane processes.
Nagarale, R K; Gohil, G S; Shahi, Vinod K
2006-02-28
Rapid growth of chemical and biotechnology in diversified areas fuels the demand for the need of reliable green technologies for the down stream processes, which include separation, purification and isolation of the molecules. Ion-exchange membrane technologies are non-hazardous in nature and being widely used not only for separation and purification but their application also extended towards energy conversion devices, storage batteries and sensors etc. Now there is a quite demand for the ion-exchange membrane with better selectivities, less electrical resistance, high chemical, mechanical and thermal stability as well as good durability. A lot of work has been done for the development of these types of ion-exchange membranes during the past twenty-five years. Herein we have reviewed the preparation of various types of ion-exchange membranes, their characterization and applications for different electro-membrane processes. Primary attention has been given to the chemical route used for the membrane preparation. Several general reactions used for the preparation of ion-exchange membranes were described. Methodologies used for the characterization of these membranes and their applications were also reviewed for the benefit of readers, so that they can get all information about the ion-exchange membranes at one platform. Although there are large number of reports available regarding preparations and applications of ion-exchange membranes more emphasis were predicted for the usefulness of these membranes or processes for solving certain type of industrial or social problems. More efforts are needed to bring many products or processes to pilot scale and extent their applications.
Jones, R.; Pearson, J.; Cawsey, A.; Barrett, A.
1996-01-01
Although there are a number of groups working on the provision of personalized patient information there has been little evaluation. We have developed and piloted a method of giving patients on-line access to their own medical records with associated explanations. We are comparing, in a randomised trial, personalized with general computer based information for patients undergoing radiotherapy for cancer. We present results from the pilot study and the evaluation methods to be employed. PMID:8947701
The psychophysiological assessment method for pilot's professional reliability.
Zhang, L M; Yu, L S; Wang, K N; Jing, B S; Fang, C
1997-05-01
Previous research has shown that a pilot's professional reliability depends on two relative factors: the pilot's functional state and the demands of task workload. The Psychophysiological Reserve Capacity (PRC) is defined as a pilot's ability to accomplish additive tasks without reducing the performance of the primary task (flight task). We hypothesized that the PRC was a mirror of the pilot's functional state. The purpose of this study was to probe the psychophysiological method for evaluating a pilot's professional reliability on a simulator. The PRC Comprehensive Evaluating System (PRCCES) which was used in the experiment included four subsystems: a) quantitative evaluation system for pilot's performance on simulator; b) secondary task display and quantitative estimating system; c) multiphysiological data monitoring and statistical system; and d) comprehensive evaluation system for pilot PRC. Two studies were performed. In study one, 63 healthy and 13 hospitalized pilots participated. Each pilot performed a double 180 degrees circuit flight program with and without secondary task (three digit operation). The operator performance, score of secondary task and cost of physiological effort were measured and compared by PRCCES in the two conditions. Then, each pilot's flight skill in training was subjectively scored by instructor pilot ratings. In study two, 7 healthy pilots volunteered to take part in the experiment on the effects of sleep deprivation on pilot's PRC. Each participant had PRC tested pre- and post-8 h sleep deprivation. The results show that the PRC values of a healthy pilot was positively correlated with abilities of flexibility, operating and correcting deviation, attention distribution, and accuracy of instrument flight in the air (r = 0.27-0.40, p < 0.05), and negatively correlated with emotional anxiety in flight (r = -0.40, p < 0.05). The values of PRC in healthy pilots (0.61 +/- 0.17) were significantly higher than that of hospitalized pilots (0.43 +/- 0.15) (p < 0.05). The PRC value after 8 h sleep loss (0.50 +/- 0.17) was significantly lower than those before sleep loss (0.70 +/- 0.15) (p < 0.05). We conclude that a pilot's PRC, which was closely related to flight ability and functional state, could partly represent the pilot's professional reliability. It is worthwhile to further research using a pilot's PRC as a predictor of mental workload in aircraft design.
Brief report: Bereaved parents informing research design: The place of a pilot study.
Donovan, L A; Wakefield, C E; Russell, V; Hetherington, Kate; Cohn, R J
2018-02-23
Risk minimization in research with bereaved parents is important. However, little is known about which research methods balance the sensitivity required for bereaved research participants and the need for generalizable results. To explore parental experiences of participating in mixed method bereavement research via a pilot study. A convergent parallel mixed method design assessing bereaved parents' experience of research participation. Eleven parents whose child was treated for cancer at The Royal Children's Hospital, Brisbane completed the questionnaire/interview being piloted (n = 8 mothers; n = 3 fathers; >6 months and <6 years bereaved). Of these, eight parents completed the pilot study evaluation questionnaire, providing feedback on their experience of participation. Participants acknowledged the importance of bereaved parents being central to research design and the development of bereavement programs. Sixty-three per cent (n = 5/8) of parents described completion of the questionnaire as 'not at all/a little bit' of a burden. Seventy-five per cent (n = 6/8) of parents opting into the telephone interview described participation as 'not at all/a little bit' of a burden. When considering the latest timeframes for participation in bereavement research 63% (n = 5/8) of parents indicated 'no endpoint.' Findings from the pilot study enabled important adjustments to be made to a large-scale future study. As a research method, pilot studies may be utilized to minimize harm and maximize the potential benefits for vulnerable research participants. A mixed method approach allows researchers to generalize findings to a broader population while also drawing on the depth of the lived experience.
Quality of reporting of pilot and feasibility cluster randomised trials: a systematic review
Chan, Claire L; Leyrat, Clémence; Eldridge, Sandra M
2017-01-01
Objectives To systematically review the quality of reporting of pilot and feasibility of cluster randomised trials (CRTs). In particular, to assess (1) the number of pilot CRTs conducted between 1 January 2011 and 31 December 2014, (2) whether objectives and methods are appropriate and (3) reporting quality. Methods We searched PubMed (2011–2014) for CRTs with ‘pilot’ or ‘feasibility’ in the title or abstract; that were assessing some element of feasibility and showing evidence the study was in preparation for a main effectiveness/efficacy trial. Quality assessment criteria were based on the Consolidated Standards of Reporting Trials (CONSORT) extensions for pilot trials and CRTs. Results Eighteen pilot CRTs were identified. Forty-four per cent did not have feasibility as their primary objective, and many (50%) performed formal hypothesis testing for effectiveness/efficacy despite being underpowered. Most (83%) included ‘pilot’ or ‘feasibility’ in the title, and discussed implications for progression from the pilot to the future definitive trial (89%), but fewer reported reasons for the randomised pilot trial (39%), sample size rationale (44%) or progression criteria (17%). Most defined the cluster (100%), and number of clusters randomised (94%), but few reported how the cluster design affected sample size (17%), whether consent was sought from clusters (11%), or who enrolled clusters (17%). Conclusions That only 18 pilot CRTs were identified necessitates increased awareness of the importance of conducting and publishing pilot CRTs and improved reporting. Pilot CRTs should primarily be assessing feasibility, avoiding formal hypothesis testing for effectiveness/efficacy and reporting reasons for the pilot, sample size rationale and progression criteria, as well as enrolment of clusters, and how the cluster design affects design aspects. We recommend adherence to the CONSORT extensions for pilot trials and CRTs. PMID:29122791
Learning About Cockpit Automation: From Piston Trainer to Jet Transport
NASA Technical Reports Server (NTRS)
Casner, Stephen M.
2003-01-01
Two experiments explored the idea of providing cockpit automation training to airline-bound student pilots using cockpit automation equipment commonly found in small training airplanes. In a first experiment, pilots mastered a set of tasks and maneuvers using a GPS navigation computer, autopilot, and flight director system installed in a small training airplane Students were then tested on their ability to complete a similar set of tasks using the cockpit automation system found in a popular jet transport aircraft. Pilot were able to successfully complete 77% of all tasks in the jet transport on their first attempt. An analysis of a control group suggests that the pilot's success was attributable to the application of automation principles they had learned in the small airplane. A second experiment looked at two different ways of delivering small-aeroplane cockpit automation training: a self-study method, and a dual instruction method. The results showed a slight advantage for the self-study method. Overall, the results of the two studies cast a strong vote for the incorporation of cockpit automation training in curricula designed for pilot who will later transition to the jet fleet.
Membrane technology applied to acid mine drainage from copper mining.
Ambiado, K; Bustos, C; Schwarz, A; Bórquez, R
2017-02-01
The objective of this study is to evaluate the treatment of high-strength acid mine drainage (AMD) from copper mining by nanofiltration (NF) and reverse osmosis (RO) at pilot scale. The performances of two commercial spiral-wound membranes - NF99 and RO98pHt, both from Alfa Laval - were compared. The effects of pressure and feed flow on ion rejection and permeate flux were evaluated. The results showed high ion removal under optimum pressure conditions, which reached 92% for the NF99 membrane and 98% for the RO98pHt membrane. Sulfate removal reached 97% and 99% for NF99 and RO98pHt, respectively. In the case of copper, aluminum, iron and manganese, the removal percentage surpassed 95% in both membranes. Although concentration polarization limited NF performance at higher pressures, permeate fluxes observed in NF were five times greater than those obtained by RO, with only slightly lower divalent ion rejection rates, making it a promising option for the treatment of AMD.
Corbellini, Ezio; Corbellini, Monica; Licciardello, Orazio; Marotta, Francesco
2014-04-01
The QUEC PHISIS(™) technology, based on the theory of coherence domains of water, is the most advanced application of quantum electrodynamics coherence suitable for transferring highly targeted and personalized electromagnetic signals to the living cells. Several experimental studies in aged rats confirm its beneficial action on vital cellular parameters while also optimizing the bioavailability and absorption of fundamental elements in cellular metabolism. Clinical observations have followed and have strengthened its applicability in healthy volunteers and in patients with complex diseases such as cardiovascular, neuromuscular, and metabolic disorders. Our pilot study on severely compromised, frail subjects corroborates its relevance. The delivery of correct frequencies has the potential to become a safe, very affordable, and effective therapeutic modality that is amenable to being integrated with pharmacological drugs, thus representing a substantial innovation in medical practice.
1969-11-19
AS12-47-6918 (19 Nov. 1969) --- Astronaut Alan L. Bean, lunar module pilot, took this photograph of three of the components of the Apollo Lunar Surface Experiments Package (ALSEP) which was deployed on the moon during the first Apollo 12 extravehicular activity (EVA). The Passive Seismic Experiment (PSE) is in the center foreground. The largest object is the Central Station; and the white object on legs is the Suprathermal Ion Detector Experiment (SIDE). A portion of the shadow of astronaut Charles Conrad Jr., commander, can be seen at the left center edge of the picture. Astronaut Richard F. Gordon Jr., command module pilot, remained with the Apollo 12 Command and Service Modules (CSM) in lunar orbit while Conrad and Bean descended in the Lunar Module (LM) to explore the moon.
ERIC Educational Resources Information Center
Nicklas, Theresa A.; O'Neil, Carol E.; Stuff, Janice; Goodell, Lora Suzanne; Liu, Yan; Martin, Corby K.
2012-01-01
Objective: The goal of the study was to assess the validity and feasibility of a digital diet estimation method for use with preschool children in "Head Start." Methods: Preschool children and their caregivers participated in validation (n = 22) and feasibility (n = 24) pilot studies. Validity was determined in the metabolic research unit using…
Apparatus and method of dissociating ions in a multipole ion guide
Webb, Ian K.; Tang, Keqi; Smith, Richard D.; Ibrahim, Yehia M.; Anderson, Gordon A.
2014-07-08
A method of dissociating ions in a multipole ion guide is disclosed. A stream of charged ions is supplied to the ion guide. A main RF field is applied to the ion guide to confine the ions through the ion guide. An excitation RF field is applied to one pair of rods of the ion guide. The ions undergo dissociation when the applied excitation RF field is resonant with a secular frequency of the ions. The multipole ion guide is, but not limited to, a quadrupole, a hexapole, and an octopole.
Akter, Fouzia; Saito, Shingo; Tasaki-Handa, Yuiko; Shibukawa, Masami
2018-01-01
A new analytical methodology for a simple and efficient on-line preconcentration of trace inorganic anions in water and salt samples prior to ion chromatographic determination is proposed. The preconcentration method is based on partition/ion-exclusion chromatographic ion stacking (PIEC ion stacking) with a hydrophilic polymer gel column containing a small amount of fixed anionic charges. The developed on-line PIEC ion stacking-ion chromatography method was validated by recovery experiments for the determination of nitrate in tap water in terms of both accuracy and precision, and the results showed the reliability of the method. The method proposed was also successfully applied to the determination of trace impurity nitrite and nitrate in reagent-grade salts of sodium sulfate. A low background level can be achieved since pure water is used as the eluant for the PIEC ion stacking. It is possible to reach sensitive detection at sub-μg L -1 levels by on-line PIEC ion stacking-ion chromatography.
NASA Astrophysics Data System (ADS)
Šantić, Branko; Gracin, Davor
2017-12-01
A new simple Monte Carlo method is introduced for the study of electrostatic screening by surrounding ions. The proposed method is not based on the generally used Markov chain method for sample generation. Each sample is pristine and there is no correlation with other samples. As the main novelty, the pairs of ions are gradually added to a sample provided that the energy of each ion is within the boundaries determined by the temperature and the size of ions. The proposed method provides reliable results, as demonstrated by the screening of ion in plasma and in water.
Pilot-aided feedforward data recovery in optical coherent communications
DOE Office of Scientific and Technical Information (OSTI.GOV)
Qi, Bing
2017-09-19
A method and a system for pilot-aided feedforward data recovery are provided. The method and system include a receiver including a strong local oscillator operating in a free running mode independent of a signal light source. The phase relation between the signal light source and the local oscillator source is determined based on quadrature measurements on pilot pulses from the signal light source. Using the above phase relation, information encoded in an incoming signal can be recovered, optionally for use in communication with classical coherent communication protocols and quantum communication protocols.
Study of occupational stress among railway engine pilots
Kumar, Devesh; Singh, Jai Vir; Kharwar, Poonam S.
2011-01-01
Background: Traffic volume and speed is going to be increased in Indian Railways successively, leading to higher stress in staff connected with train operations. The jobs of railway engine pilots come under the category of high-strain jobs, necessitating a need to conduct multicentric study to unfold the factors associated with occupational stress and organizational strategies. Materials and Methods: Present study covered 185 railway engine pilots and office clerks working in various railway zones by incidental method. Occupational Stress Index (OSI) test developed by Srivastva and Singh, questionnaire of specific stressors constructed by authors and laboratory test battery for psychological screening of high-speed train pilots were used as tools. Results: Means of OSI and all the 12 occupational stressors of railway engine pilots were found significantly higher to that of office clerks. Means of OSI and occupational stressors of goods train pilots were significantly higher in comparison to high-speed train pilots and passenger train pilots. Study revealed positive correlation of speed perception and complex reaction time tests and negative correlation of other constituent tests of laboratory test battery to OSI test. Highest subgroup of stressor observedwas role overload followed by role conflict. Conclusions: These findings provide a prima facie evidence of higher occupational stress among railway engine pilots because of identified specific stressors prevalent in their job and explore the possible intervention strategies for its reduction. Significant correlation is noticed between OSI and laboratory test results, indicating its relevant utility in preliminary psychological screening. PMID:21808497
Monitoring of pre-frontal oxygen status in helicopter pilots using near-infrared spectrophotometers
Kikukawa, Azusa; Kobayashi, Asao; Miyamoto, Yoshinori
2008-01-01
Background There are few in-flight studies of cognition-related cerebral oxygen status in helicopter pilots. Methods Four male helicopter pilots volunteered for nine sorties during visual flight in a BK117 and UH-60J. The pilots' pre-frontal oxy-hemoglobin (O2Hb) and deoxy-hemoglobin (HHb) concentration were continuously monitored from the right/left sections of the forehead using near-infrared spectrophotometers with a consideration of motion artifacts. Results The concentration of O2Hb progressively increased (13.98 μmol•L-1 as a maximum increased concentration) in both the right/left sections of the forehead from the basal level during the heightened cognitive demand of helicopter flight. There was comparatively little change (4.32 μmol•L-1 as a maximum increased concentration) in HHb concentration during measurement of helicopter flight. HHb changes were apparently not affected by a heightened cognitive demand of helicopter pilots. Conclusion These results demonstrate that near-infrared spectroscopy, especially O2Hb measurements, provides a sensitive method for the monitoring of cognitive demand (maneuvers) in helicopter pilots. PMID:18616829
Grajewski, Barbara; Waters, Martha A.; Yong, Lee C.; Tseng, Chih-Yu; Zivkovich, Zachary; Cassinelli II, Rick T.
2011-01-01
Objectives: US commercial airline pilots, like all flight crew, are at increased risk for specific cancers, but the relation of these outcomes to specific air cabin exposures is unclear. Flight time or block (airborne plus taxi) time often substitutes for assessment of exposure to cosmic radiation. Our objectives were to develop methods to estimate exposures to cosmic radiation and circadian disruption for a study of chromosome aberrations in pilots and to describe workplace exposures for these pilots. Methods: Exposures were estimated for cosmic ionizing radiation and circadian disruption between August 1963 and March 2003 for 83 male pilots from a major US airline. Estimates were based on 523 387 individual flight segments in company records and pilot logbooks as well as summary records of hours flown from other sources. Exposure was estimated by calculation or imputation for all but 0.02% of the individual flight segments’ block time. Exposures were estimated from questionnaire data for a comparison group of 51 male university faculty. Results: Pilots flew a median of 7126 flight segments and 14 959 block hours for 27.8 years. In the final study year, a hypothetical pilot incurred an estimated median effective dose of 1.92 mSv (absorbed dose, 0.85 mGy) from cosmic radiation and crossed 362 time zones. This study pilot was possibly exposed to a moderate or large solar particle event a median of 6 times or once every 3.7 years of work. Work at the study airline and military flying were the two highest sources of pilot exposure for all metrics. An index of work during the standard sleep interval (SSI travel) also suggested potential chronic sleep disturbance in some pilots. For study airline flights, median segment radiation doses, time zones crossed, and SSI travel increased markedly from the 1990s to 2003 (Ptrend < 0.0001). Dose metrics were moderately correlated with records-based duration metrics (Spearman’s r = 0.61–0.69). Conclusions: The methods developed provided an exposure profile of this group of US airline pilots, many of whom have been exposed to increasing cosmic radiation and circadian disruption from the 1990s through 2003. This assessment is likely to decrease exposure misclassification in health studies. PMID:21610083
Calibrating ion density profile measurements in ion thruster beam plasma
NASA Astrophysics Data System (ADS)
Zhang, Zun; Tang, Haibin; Ren, Junxue; Zhang, Zhe; Wang, Joseph
2016-11-01
The ion thruster beam plasma is characterized by high directed ion velocity (104 m/s) and low plasma density (1015 m-3). Interpretation of measurements of such a plasma based on classical Langmuir probe theory can yield a large experimental error. This paper presents an indirect method to calibrate ion density determination in an ion thruster beam plasma using a Faraday probe, a retarding potential analyzer, and a Langmuir probe. This new method is applied to determine the plasma emitted from a 20-cm-diameter Kaufman ion thruster. The results show that the ion density calibrated by the new method can be as much as 40% less than that without any ion current density and ion velocity calibration.
Method for Continuous Monitoring of Electrospray Ion Formation
NASA Astrophysics Data System (ADS)
Metzler, Guille; Crathern, Susan; Bachmann, Lorin; Fernández-Metzler, Carmen; King, Richard
2017-10-01
A method for continuously monitoring the performance of electrospray ionization without the addition of hardware or chemistry to the system is demonstrated. In the method, which we refer to as SprayDx, cluster ions with solvent vapor natively formed by electrospray are followed throughout the collection of liquid chromatography-selected reaction monitoring data. The cluster ion extracted ion chromatograms report on the consistency of the ion formation and detection system. The data collected by the SprayDx method resemble the data collected for postcolumn infusion of analyte. The response of the cluster ions monitored reports on changes in the physical parameters of the ion source such as voltage and gas flow. SprayDx is also observed to report on ion suppression in a fashion very similar to a postcolumn infusion of analyte. We anticipate the method finding utility as a continuous readout on the performance of electrospray and other atmospheric pressure ionization processes. [Figure not available: see fulltext.
Anthropometry. A Bibliography with Abstracts
1975-08-01
nces fro signific e shirt- (Author) o US per ach ions wea ed. angu obta m t ant slee AF pilots sonal p en velone : d) s ring com...side measured bility. s of the human neck which may influence a person’s • whiplash ’ injury during lateral impact have oeen mal subjects. Subjects...group of lb subjects Deing n average stature close to the both ptrcentile tor data include: measures of head , neck and body anding and normal
McLuckey, Scott A.; Mentinova, Marija
2011-01-01
A range of strategies and tools has been developed to facilitate the determination of primary structures of analyte molecules of interest via tandem mass spectrometry (MS/MS). The two main factors that determine the primary structural information present in an MS/MS spectrum are the type of ion generated from the analyte molecule and the dissociation method. The ion-type subjected to dissociation is determined by the ionization method/conditions and ion transformation processes that might take place after initial gas-phase ion formation. Furthermore, the range of analyte-related ion types can be expanded via derivatization reactions prior to mass spectrometry. Dissociation methods include those that simply alter the population of internal states of the mass-selected ion (i.e., activation methods like collision-induced dissociation) as well as processes that rely on transformation of the ion-type prior to dissociation (e.g., electron capture dissociation). A variety of ionic interactions has been studied for the purpose of ion dissociation and ion transformation that include ion/neutral, ion/photon, ion/electron, and ion/ion interactions. A wide range of phenomena has been observed, many of which have been explored/developed as means for structural analysis. The techniques arising from these phenomena are discussed within the context of the elements of structure determination in tandem mass spectrometry, viz., ion-type definition and dissociation. Unique aspects of the various ion interactions are emphasized along with any barriers to widespread implementation. PMID:21472539
Direct Method for Continuous Determination of Iron Oxidation by Autotrophic Bacteria
Steiner, Michael; Lazaroff, Norman
1974-01-01
A method for direct, continuous determination of ferric ions produced in autotrophic iron oxidation, which depends upon the measurement of ferric ion absorbance at 304 nm, is described. The use of initial rates is shown to compensate for such changes in extinction during oxidation, which are due to dependence of the extinction coefficient on the ratio of complexing anions to ferric ions. A graphical method and a computer method are given for determination of absolute ferric ion concentration, at any time interval, in reaction mixtures containing Thiobacillus ferrooxidans and ferrous ions at known levels of SO42+ and hydrogen ion concentrations. Some examples are discussed of the applicability of these methods to study of the rates of ferrous ion oxidation related to sulfate concentration. PMID:4441066
Systems and Methods for Ejection of Ions from an Ion Trap
NASA Technical Reports Server (NTRS)
Cooks, Robert Graham (Inventor); Snyder, Dalton (Inventor)
2018-01-01
The invention generally relates to systems and methods for ejection of ions from an ion trap. In certain embodiments, systems and methods of the invention sum two different frequency signals into a single summed signal that is applied to an ion trap. In other embodiments, an amplitude of a single frequency signal is modulated as the single frequency signal is being applied to the ion trap. In other embodiments, a first alternating current (AC) signal is applied to an ion trap that varies as a function of time, while a constant radio frequency (RF) signal is applied to the ion trap.
Closed cycle ion exchange method for regenerating acids, bases and salts
Dreyfuss, Robert M.
1976-01-01
A method for conducting a chemical reaction in acidic, basic, or neutral solution as required and then regenerating the acid, base, or salt by means of ion exchange in a closed cycle reaction sequence which comprises contacting the spent acid, base, or salt with an ion exchanger, preferably a synthetic organic ion-exchange resin, so selected that the counter ions thereof are ions also produced as a by-product in the closed reaction cycle, and then regenerating the spent ion exchanger by contact with the by-product counter ions. The method is particularly applicable to closed cycle processes for the thermochemical production of hydrogen.
Flight Deck Interval Management Avionics: Eye-Tracking Analysis
NASA Technical Reports Server (NTRS)
Latorella, Kara; Harden, John W.
2015-01-01
Interval Management (IM) is one NexGen method for achieving airspace efficiencies. In order to initiate IM procedures, Air Traffic Control provides an IM clearance to the IM aircraft's pilots that indicates an intended spacing from another aircraft (the target to follow - or TTF) and the point at which this should be achieved. Pilots enter the clearance in the flight deck IM (FIM) system; and once the TTF's Automatic Dependent Surveillance-Broadcast signal is available, the FIM algorithm generates target speeds to meet that IM goal. This study examined four Avionics Conditions (defined by the instrumentation and location presenting FIM information) and three Notification Methods (defined by the visual and aural alerts that notified pilots to IM-related events). Current commercial pilots flew descents into Dallas/Fort-Worth in a high-fidelity commercial flight deck simulation environment with realistic traffic and communications. All 12 crews experienced each Avionics Condition, where order was counterbalanced over crews. Each crew used only one of the three Notification Methods. This paper presents results from eye tracking data collected from both pilots, including: normalized number of samples falling within FIM displays, normalized heads-up time, noticing time, dwell time on first FIM display look after a new speed, a workload-related metric, and a measure comparing the scan paths of pilot flying and pilot monitoring; and discusses these in the context of other objective (vertical and speed profile deviations, response time to dial in commanded speeds, out-of-speed-conformance and reminder indications) and subjective measures (workload, situation awareness, usability, and operational acceptability).
Monteiro, Márcia; Carvalho, Márcia; Henrique, Rui; Jerónimo, Carmen; Moreira, Nathalie; de Lourdes Bastos, Maria; de Pinho, Paula Guedes
2014-07-01
A new and simple analytical approach consisting of headspace-solid phase microextraction (HS-SPME) sampling coupled with gas chromatography-ion trap/mass spectrometry (GC-IT/MS) was developed to study the volatile human urinary metabolome. A central composite design (CCD) was used in the optimisation of extraction conditions. Fibre selection and evaluation of pH influence were performed using an univariate mode and the influence of other parameters, such as the time and temperature of extraction, time of incubation and salt addition, that affect the efficiency of the SPME sampling, was carried out using a CCD. With a sample volume of 2 mL, the optimal conditions in terms of total response values and reproducibility were achieved by performing analyses with a divinylbenzene/polydimethylsiloxane (DVB/PDMS) fibre, in an acidic pH (pH 2) with the addition of 0.59 g of NaCl, allowing the sample to equilibrate for 9 min and extracting at 68 °C for 24 min. The applicability of the optimised method was then tested in a pilot non-target analysis of urine samples obtained from patients with renal cell carcinoma (RCC) and healthy individuals. Chemometric unsupervised analyses performed on the volatile pattern acquired for these samples clearly showed the potential of volatile urinary metabolome to discriminate between RCC and control patients. Copyright © 2014 Elsevier Ltd. All rights reserved.
Zhang, Hong-Jia; Fan, Xiao-Guang; Qiu, Xue-Liang; Zhang, Qiu-Xiang; Wang, Wen-Ya; Li, Shuang-Xi; Deng, Li-Hong; Koffas, Mattheos A G; Wei, Dong-Sheng; Yuan, Qi-Peng
2014-12-01
Steam explosion is the most promising technology to replace conventional acid hydrolysis of lignocellulose for biomass pretreatment. In this paper, a new screw-steam-explosive extruder was designed and explored for xylose production and lignocellulose biorefinery at the pilot scale. We investigated the effect of different chemicals on xylose yield in the screw-steam-explosive extrusion process, and the xylose production process was optimized as followings: After pre-impregnation with sulfuric acid at 80 °C for 3 h, corncob was treated at 1.55 MPa with 9 mg sulfuric acid/g dry corncob (DC) for 5.5 min, followed by countercurrent extraction (3 recycles), decoloration (activated carbon dosage 0.07 g/g sugar, 75 °C for 40 min), and ion exchange (2 batches). Using this process, 3.575 kg of crystal xylose was produced from 22 kg corncob, almost 90 % of hemicellulose was released as monomeric sugar, and only a small amount of by-products was released (formic acid, acetic acid, fural, 5-hydroxymethylfurfural, and phenolic compounds were 0.17, 1.14, 0.53, 0.19, and 1.75 g/100 g DC, respectively). All results indicated that the screw-steam-explosive extrusion provides a more effective way to convert hemicellulose into xylose and could be an alternative method to traditional sulfuric acid hydrolysis process for lignocellulose biorefinery.
Identification of Time-Varying Pilot Control Behavior in Multi-Axis Control Tasks
NASA Technical Reports Server (NTRS)
Zaal, Peter M. T.; Sweet, Barbara T.
2012-01-01
Recent developments in fly-by-wire control architectures for rotorcraft have introduced new interest in the identification of time-varying pilot control behavior in multi-axis control tasks. In this paper a maximum likelihood estimation method is used to estimate the parameters of a pilot model with time-dependent sigmoid functions to characterize time-varying human control behavior. An experiment was performed by 9 general aviation pilots who had to perform a simultaneous roll and pitch control task with time-varying aircraft dynamics. In 8 different conditions, the axis containing the time-varying dynamics and the growth factor of the dynamics were varied, allowing for an analysis of the performance of the estimation method when estimating time-dependent parameter functions. In addition, a detailed analysis of pilots adaptation to the time-varying aircraft dynamics in both the roll and pitch axes could be performed. Pilot control behavior in both axes was significantly affected by the time-varying aircraft dynamics in roll and pitch, and by the growth factor. The main effect was found in the axis that contained the time-varying dynamics. However, pilot control behavior also changed over time in the axis not containing the time-varying aircraft dynamics. This indicates that some cross coupling exists in the perception and control processes between the roll and pitch axes.
ERIC Educational Resources Information Center
Stergiopoulos, Vicky; Maggi, Julie; Sockalingam, Sanjeev
2009-01-01
Objective: The authors describe a pilot physician-manager curriculum designed to address the learning needs of psychiatric residents in administrative psychiatry and health systems. Methods: The pilot curriculum includes a junior and a senior toolkit of four workshops each. The junior toolkit introduces postgraduate-year two (PGY-2) residents to…
An Exploration of the Importance of Piloting and Access as Action Research
ERIC Educational Resources Information Center
Gudmundsdottir, Greta Bjork; Brock-Utne, Birgit
2010-01-01
In this article we illustrate how the piloting process has influenced two widely different studies within the educational sciences. These studies differ in design but have as a common denominator that they used piloting methods in their preparatory process. They are also similar in the intention of the main researchers of conducting research with…
NASA Technical Reports Server (NTRS)
Jones, Denise R.; Abbott, Terence S.; Burley, James R., II
1993-01-01
A piloted simulation study has been conducted to evaluate two methods of presenting attitude information in a helmet-mounted display (HMD) for spatial awareness in a fighter airplane. One method, the body-axis concept, displayed the information relative to the body axis of the airplane. The quantitative results of this study favored the body-axis concept. Although no statistically significant differences were noted for either the pilots' understanding of roll attitude or target position, the pilots made pitch judgment errors three times more often with the conformal display. The subjective results showed the body-axis display did not cause attitude confusion, a prior concern with this display. In the posttest comments, the pilots overwhelmingly selected the body-axis display as the display of choice.
ERIC Educational Resources Information Center
Akinde, Oluwatoyin Adenike
2015-01-01
This work is a pilot study on the learning outcomes of students, who were taught a research course for seven weeks, using didactic and Socratic instruction methods. The course was taught in two sessions concurrently. The students were divided into two groups (A and B) and both groups were taught either with Socratic instruction method or didactic…
ERIC Educational Resources Information Center
Crisp, Victoria; Novakovic, Nadezda
2009-01-01
Maintaining standards over time is a much debated topic in the context of national examinations in the UK. This study used a pilot method to compare the demands, over time, of two examination units testing administration. The method involved 15 experts revising a framework of demand types and making paired comparisons of examinations from…
Cross-sectional study of neck pain and cervical sagittal alignment in air force pilots.
Moon, Bong Ju; Choi, Kyong Ho; Yun, Chul; Ha, Yoon
2015-05-01
There is a high prevalence of neck pain in air force pilots; however, the causes are not clear and are considered work-related. Kyphotic changes in the cervical spine have been known to cause neck pain. In this study, we investigated the association between neck pain and cervical kyphosis in air force pilots. This is a cross-sectional study of 63 Republic of South Korea Air Force pilots. We examined the C2-7 absolute rotation angle (ARA) using the posterior tangent method and other radiologic parameters on whole spine lateral radiographs. We divided the participants into a neck pain group (N = 32) and no neck pain group (N = 31), and subsequently analyzed the difference in radiographic parameters and clinical data between the two groups. There were no significant differences found in age, body mass index, total flight time, or aerobic or anaerobic exercise between the neck pain and control groups. The fighter pilots had higher 1-yr prevalence of neck pain than nonfighter pilots (84.4% vs. 15.6%). The lower C2-7 ARA (OR = 0.91, 95% CI 0.846, 0.979) and fighter type aircrafts (OR = 3.93, 95% CI 1.104, 13.989) were associated with neck pain. Fighter pilots experienced neck pain more frequently than the nonfighter pilots. Those fighter pilots suffering from neck pain were shown to have more kyphotic changes in the cervical spine than control pilots through evaluation of whole spine lateral radiographs using the posterior tangent method. These key findings suggest that the forces involved in flying a fighter type aircraft may affect cervical alignment and neck pain.
Intelligent Pilot Aids for Flight Re-Planning in Emergencies
NASA Technical Reports Server (NTRS)
Pritchett, Amy R.; Ockerman, Jennifer
2005-01-01
Effective and safe control of an aircraft may be difficult or nearly impossible for a pilot following an unexpected system failure. Without prior training, the pilot must ascertain on the fly those changes in both manual control technique and procedures that will lead to a safe landing of the aircraft. Sophisticated techniques for determining the required control techniques are now available. Likewise, a body of literature on pilot decision making provides formalisms for examining how pilots approach discrete decisions framed as the selection between options. However, other aspects of behavior, such as the task of route planning and guidance, are not as well studied. Not only is the pilot faced with possible performance changes to the aircraft dynamics, but he or she is also tasked to create a plan of actions that will effectively take the aircraft down to a safe landing. In this plan, the many actions that the pilot can perform are closely intertwined with the trajectory of the aircraft, making it difficult to accurately predict the final outcome. Coupled with the vast number of potential actions to be taken, this problem may seem intractable. This is reflected in the lack of a pre-specified procedure capable of giving pilots the ability to find a resolution for this task. This report summarizes a multi-year effort to examine methods to aid pilots in planning an approach and arrival to an airport following an aircraft systems failure. Ultimately, we hypothesize that automatic assistance to pilots can be provided in real-time in the form of improving pilot control of a damaged aircraft and providing pilots with procedural directives suitable for critical flight conditions; such systems may also benefit pilot training and procedure design. To achieve this result, a systematic, comprehensive research program was followed, building on prior research. This approach included a pencil-and-paper study with airline pilots examining methods of representing a flight route in an immediately understandable manner, and in a manner that would allow the pilot to modify an automatically-generated route and/or detect any inappropriate elements in an automatically-generated route. Likewise, a flight simulator study examined different cockpit systems for the relative merits of providing pilots with any of a variety of automated functions for emergency flight planning. The results provide specific guidance for the design of such systems.
NASA Astrophysics Data System (ADS)
Sun, M. L.; Peng, H. B.; Duan, B. H.; Liu, F. F.; Du, X.; Yuan, W.; Zhang, B. T.; Zhang, X. Y.; Wang, T. S.
2018-03-01
Borosilicate glass has potential application for vitrification of high-level radioactive waste, which attracts extensive interest in studying its radiation durability. In this study, sodium borosilicate glass samples were irradiated with 4 MeV Kr17+ ion, 5 MeV Xe26+ ion and 0.3 MeV P+ ion, respectively. The hardness of irradiated borosilicate glass samples was measured with nanoindentation in continuous stiffness mode and quasi continuous stiffness mode, separately. Extrapolation method, mean value method, squared extrapolation method and selected point method are used to obtain hardness of irradiated glass and a comparison among these four methods is conducted. The extrapolation method is suggested to analyze the hardness of ion irradiated glass. With increasing irradiation dose, the values of hardness for samples irradiated with Kr, Xe and P ions dropped and then saturated at 0.02 dpa. Besides, both the maximum variations and decay constants for three kinds of ions with different energies are similar indicates the similarity behind the hardness variation in glasses after irradiation. Furthermore, the hardness variation of low energy P ion irradiated samples whose range is much smaller than those of high energy Kr and Xe ions, has the same trend as that of Kr and Xe ions. It suggested that electronic energy loss did not play a significant role in hardness decrease for irradiation of low energy ions.
NASA Astrophysics Data System (ADS)
Han, Jin; Kim, Jong-Wook; Lee, Hiwon; Min, Byung-Kwon; Lee, Sang Jo
2009-02-01
A new microfabrication method that combines localized ion implantation and magnetorheological finishing is proposed. The proposed technique involves two steps. First, selected regions of a silicon wafer are irradiated with gallium ions by using a focused ion beam system. The mechanical properties of the irradiated regions are altered as a result of the ion implantation. Second, the wafer is processed by using a magnetorheological finishing method. During the finishing process, the regions not implanted with ion are preferentially removed. The material removal rate difference is utilized for microfabrication. The mechanisms of the proposed method are discussed, and applications are presented.
Loganathan, Kavithaa; Chelme-Ayala, Pamela; El-Din, Mohamed Gamal
2015-03-15
Membrane filtration is an effective treatment method for oil sands tailings pond recycle water (RCW); however, membrane fouling and rapid decrease in permeate flux caused by colloids, organic matter, and bitumen residues present in the RCW hinder its successful application. This pilot-scale study investigated the impact of different pretreatment steps on the performance of a ceramic ultrafiltration (CUF) membrane used for the treatment of RCW. Two treatment trains were examined: treatment train 1 consisted of coagulant followed by a CUF system, while treatment train 2 included softening (Multiflo™ system) and coagulant addition, followed by a CUF system. The results indicated that minimum pretreatment (train 1) was required for almost complete solids removal. The addition of a softening step (train 2) provided an additional barrier to membrane fouling by reducing hardness-causing ions to negligible levels. More than 99% removal of turbidity and less than 20% removal of total organic carbon were achieved regardless of the treatment train used. Permeate fluxes normalized at 20 °C of 127-130 L/m(2) h and 111-118 L/m(2) h, with permeate recoveries of 90-93% and 90-94% were observed for the treatment trains 1 and 2, respectively. It was also found that materials deposited onto the membrane surface had an impact on trans-membrane pressure and influenced the required frequencies of chemically enhanced backwashes (CEBs) and clean-in-place (CIP) procedures. The CIP performed was successful in removing fouling and scaling materials such that the CUF performance was restored to baseline levels. The results also demonstrated that due to their low turbidity and silt density index values, permeates produced in this pilot study were suitable for further treatment by high pressure membrane processes. Copyright © 2015 Elsevier Ltd. All rights reserved.
Non-destructive ion trap mass spectrometer and method
Frankevich, Vladimir E.; Soni, Manish H.; Nappi, Mario; Santini, Robert E.; Amy, Jonathan W.; Cooks, Robert G.
1997-01-01
The invention relates to an ion trap mass spectrometer of the type having an ion trapping volume defined by spaced end caps and a ring electrode. The ion trap includes a small sensing electrode which senses characteristic motion of ions trapped in said trapping volume and provides an image current. Ions are excited into characteristic motion by application of an excitation pulse to the trapped ions. The invention also relates to a method of operating such an ion trap.
NASA Technical Reports Server (NTRS)
Bortolussi, Michael R.; Hart, Sandra G.; Shively, Robert J.
1987-01-01
A simulation was conducted to determine whether the sensitivity of secondary task measures of pilot workload could be improved by synchronizing their presentation to the occurrence of specific events or pilot actions. This synchronous method of presentation was compared to the more typical asynchronous method, where secondary task presentations are independent of pilot's flight-related activities. Twelve pilots flew low- and high-difficulty scenarios in a motion-base trainer with and without concurrent secondary tasks (e.g., choice reaction time and time production). The difficulty of each scenario was manipulated by the addition of 21 flight-related tasks superimposed on a standard approach and landing sequence. The insertion of the secondary tasks did not affect primary flight performance. However, secondary task performance did reflect workload differences between scenarios and among flight segments within scenarios, replicating the results of an earlier study in which the secondary tasks were presented asynchronously (Bortolussi et al., 1986).
Shamir, Lior; Yerby, Carol; Simpson, Robert; von Benda-Beckmann, Alexander M; Tyack, Peter; Samarra, Filipa; Miller, Patrick; Wallin, John
2014-02-01
Vocal communication is a primary communication method of killer and pilot whales, and is used for transmitting a broad range of messages and information for short and long distance. The large variation in call types of these species makes it challenging to categorize them. In this study, sounds recorded by audio sensors carried by ten killer whales and eight pilot whales close to the coasts of Norway, Iceland, and the Bahamas were analyzed using computer methods and citizen scientists as part of the Whale FM project. Results show that the computer analysis automatically separated the killer whales into Icelandic and Norwegian whales, and the pilot whales were separated into Norwegian long-finned and Bahamas short-finned pilot whales, showing that at least some whales from these two locations have different acoustic repertoires that can be sensed by the computer analysis. The citizen science analysis was also able to separate the whales to locations by their sounds, but the separation was somewhat less accurate compared to the computer method.
NASA Astrophysics Data System (ADS)
Meot-Ner (Mautner), Michael; Somogyi, Árpád
2007-11-01
The internal energies of dissociating ions, activated chemically or collisionally, can be estimated using the kinetics of thermal dissociation. The thermal Arrhenius parameters can be combined with the observed dissociation rate of the activated ions using kdiss = Athermalexp(-Ea,thermal/RTeff). This Arrhenius-type relation yields the effective temperature, Teff, at which the ions would dissociate thermally at the same rate, or yield the same product distributions, as the activated ions. In turn, Teff is used to calculate the internal energy of the ions and the energy deposited by the activation process. The method yields an energy deposition efficiency of 10% for a chemical ionization proton transfer reaction and 8-26% for the surface collisions of various peptide ions. Internal energies of ions activated by chemical ionization or by gas phase collisions, and of ions produced by desorption methods such as fast atom bombardment, can be also evaluated. Thermal extrapolation is especially useful for ion-molecule reaction products and for biological ions, where other methods to evaluate internal energies are laborious or unavailable.
A novel method to estimate safety factor of capture by a fetal micropacemaker.
Vest, Adriana Nicholson; Zhou, Li; Bar-Cohen, Yaniv; Eli Loeb, Gerald
2016-07-01
We have developed a rechargeable fetal micropacemaker in order to treat severe fetal bradycardia with comorbid hydrops fetalis, a life-threatening condition in pre-term non-viable fetuses for which there are no effective treatment options. The small size and minimally invasive form factor of our design limit the volume available for circuitry and a power source. The device employs a fixed-rate and fixed-amplitude relaxation oscillator and a tiny, rechargeable lithium ion power cell. For both research and clinical applications, it is valuable to monitor the electrode-myocardium interface in order to determine that adequate pacemaker output is being provided. This is typically accomplished by observing the minimal stimulus strength that achieves threshold for pacing capture. The output of our simple micropacemaker cannot be programmatically altered to determine this minimal capture threshold, but a safety factor can be inferred by determining the refractory period for ventricular capture at a given stimulus strength. This is done by measuring the minimal timing between naturally occurring QRS complexes and pacing stimuli that successfully generate a premature ventricular contraction. The method was tested in a pilot study in four fetal sheep and the data demonstrate that a relative measure of threshold is obtainable. This method provides valuable real-time information about the electrode-tissue interface.
A novel method to estimate safety factor of capture by a fetal micropacemaker
Vest, Adriana Nicholson; Zhou, Li; Bar-Cohen, Yaniv; Loeb, Gerald Eli
2016-01-01
We have developed a rechargeable fetal micropacemaker in order to treat severe fetal bradycardia with comorbid hydrops fetalis, a life-threatening condition in pre-term non-viable fetuses for which there are no effective treatment options. The small size and minimally invasive form factor of our design limit the volume available for circuitry and a power source. The device employs a fixed-rate and fixed-amplitude relaxation oscillator and a tiny, rechargeable lithium ion power cell. For both research and clinical applications, it is valuable to monitor the electrode-myocardium interface in order to determine that adequate pacemaker output is being provided. This is typically accomplished by observing the minimal stimulus strength that achieves threshold for pacing capture. The output of our simple micropacemaker cannot be programmatically altered to determine this minimal capture threshold, but a safety factor can be inferred by determining the refractory period for ventricular capture at a given stimulus strength. This is done by measuring the minimal timing between naturally occurring QRS complexes and pacing stimuli that successfully generate a premature ventricular contraction. The method was tested in a pilot study in 4 fetal sheep and the data demonstrate that a relative measure of threshold is obtainable. This method provides valuable real-time information about the electrode-tissue interface. PMID:27340134
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cooks, Robert Graham; Li, Anyin; Luo, Qingjie
The invention generally relates to systems and methods for producing metal clusters; functionalized surfaces; and droplets including solvated metal ions. In certain aspects, the invention provides methods that involve providing a metal and a solvent. The methods additionally involve applying voltage to the solvated metal to thereby produce solvent droplets including ions of the metal containing compound, and directing the solvent droplets including the metal ions to a target. In certain embodiments, once at the target, the metal ions can react directly or catalyze reactions.
Cooks, Robert Graham; Li, Anyin; Luo, Qingjie
2017-01-24
The invention generally relates to systems and methods for producing metal clusters; functionalized surfaces; and droplets including solvated metal ions. In certain aspects, the invention provides methods that involve providing a metal and a solvent. The methods additionally involve applying voltage to the solvated metal to thereby produce solvent droplets including ions of the metal containing compound, and directing the solvent droplets including the metal ions to a target. In certain embodiments, once at the target, the metal ions can react directly or catalyze reactions.
ANALYSIS OF FERRIC AND FERROUS IONS IN SOIL EXTRACTS BY ION CHROMATOGRAPHY
A method using ion chromatography (IC) for the analysis of ferrous (Fe 2+) and ferric (Fe 3+) ions in soil extracts has been developed. This method uses an ion exchange column with detection at 520 nm after post-column derivatization. Selectivity is achieved by using an anionic...
ERIC Educational Resources Information Center
Connelly, Edward A.; And Others
A new approach to deriving human performance measures and criteria for use in automatically evaluating trainee performance is documented in this report. The ultimate application of the research is to provide methods for automatically measuring pilot performance in a flight simulator or from recorded in-flight data. An efficient method of…
A pilot study was conducted to evaluate methods of assessment of exposure of infants and toddlers to pesticide residues around the household. ine homes with children aged six months to five years were selected on the basis of pesticide indoor and outdoor use. ouse dust was collec...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-09-16
... airman and medical certificates to be requested online, or by any other method acceptable to the... number FAA-2013- 0780 using any of the following methods: Federal eRulemaking Portal: Go to http://www... (g) is an exception regarding a student pilot and remains as it was previously written. In a recent...
ERIC Educational Resources Information Center
Thebaud, Schiller
This report examines four UNESCO pilot projects undertaken in 1972 in Brazil, Colombia, Peru, and Uruguay to study the methods used for national statistical surveys of science and technology. The projects specifically addressed the problems of comparing statistics gathered by different methods in different countries. Surveys carried out in Latin…
Research Teaching Pedagogy: Lessons Learned from an Arabic Language Intervention Pilot Study
ERIC Educational Resources Information Center
Christ, Thomas W.; Elmetaher, Hosam
2012-01-01
Teaching mixed methods and action research to graduate students has great advantages but also poses interesting challenges. The purpose of this article is to make transparent the process by which a mixed methods research instructor helped inform a student-researcher of the limitations in a pilot study that was compromised by methodology, including…
Remediation of DNAPL through Sequential In Situ Chemical Oxidation and Bioaugmentation
2009-04-01
Specific Electrode Field Field-filtered, ICP - PSC 0.05 mg/L 125 mL plastic nitric acid to pHɚ 28 days cool to 4oC Ion Chromatography 25310 C PSC 0.2...oxidized by MnO2 at a significant rate; however, MnO2 reacted rapidly with oxalic acid ; • Complete dechlorination occurred only in microcosms...controller PLFA phospholipid fatty acid ppb parts per billion PTA pilot test area PVC polyvinyl chloride QAPP quality assurance project plan QA
Development of a universal solvent for the decontamination of acidic liquid radioactive wastes
NASA Astrophysics Data System (ADS)
Todd, T. A.; Brewer, K. N.; Law, J. D.; Wood, D. J.; Herbest, R. S.; Romanovskiy, V. N.; Esimantovskiy, V. M.; Smirnov, I. V.; Babain, V. A.
1999-01-01
A teritiary solvent containing chlorinated cobalt dicarbollide, polyethylene glycol and diphenylcarbamoylmethylphosphine oxide was evaluated in different non-nitroaromatic diluents for the separation of cesium, strontium, actinides and rare earth elements from acidic liquid radioactive waste. Decontamination factors of >95% for Cs, 99.7% for Sr, and 99.99% for actinides were achieved in four successive batch contacts using actual radioactive waste. Pilot plant testing in centrifugal contactors using simulated wastes, has demonstrated removal of >99% of all targeted ions.
Symptoms of fatigue and coping strategies in maritime pilotage.
Chambers, Timothy P; Main, Luana C
2015-01-01
Little is known regarding the symptoms of fatigue that maritime pilots experience during shift work. Moreover, the strategies these individuals use to cope with the onset of fatigue are also unknown. The current study explored the symptoms of fatigue and coping strategies experienced by maritime pilots when on-shift. Fifty maritime pilots were recruited via an advertisement in the national association's quarterly newsletter (Mage = 51.42; SD = 9.81). Participants responded to a modified version of the questionnaire used with aviation pilots that assessed overall fatigue, and the symptoms pilots associated with fatigue on duty. Methods pilots used to cope with fatigue before shift and when on the bridge were also assessed. There were significant effects for pilot vitality on 4 categories of fatigue: cognitive dysfunction; emotional disturbance; mean physical effects; and sleepiness. There were no significant effects for vitality on any of the self-reported coping strategy factors. The findings indicated that maritime pilots experience a variety of physical, behavioural, and cognitive fatigue symptoms when on shift. Some of these symptoms are similar to those reported by aviation pilots. However, unlike aviation pilots, maritime pilots reported utilising self-sufficient coping strategies to deal with the experience of fatigue.
Description of Audio-Visual Recording Equipment and Method of Installation for Pilot Training.
ERIC Educational Resources Information Center
Neese, James A.
The Audio-Video Recorder System was developed to evaluate the effectiveness of in-flight audio/video recording as a pilot training technique for the U.S. Air Force Pilot Training Program. It will be used to gather background and performance data for an experimental program. A detailed description of the system is presented and construction and…
Impact on Seniors of the Patient-Centered Medical Home: Evidence from a Pilot Study
ERIC Educational Resources Information Center
Fishman, Paul A.; Johnson, Eric A.; Coleman, Kathryn; Larson, Eric B.; Hsu, Clarissa; Ross, Tyler R.; Liss, David; Tufano, James; Reid, Robert J.
2012-01-01
Purpose: To assess the impact on health care cost and quality among seniors of a patient-centered medical home (PCMH) pilot at Group Health Cooperative, an integrated health care system in Washington State. Design and Methods: A prospective before-and-after evaluation of the experience of seniors receiving primary care services at 1 pilot clinic…
"This Is My Best": The Report of Vermont's Writing Assessment Program, Pilot Year 1990-91.
ERIC Educational Resources Information Center
Vermont State Dept. of Education, Montpelier.
A study examined the background, methods, and results of the pilot year of Vermont's Writing Assessment program. Students and teachers from 46 Vermont schools were invited to participate in the 1990-91 pilot year of portfolio assessment. Students in grades 4 and 8 chose samples of their best writing from the school year. Each portfolio was…
Methods and apparatus for altering material using ion beams
Bloomquist, Douglas D.; Buchheit, Rudy; Greenly, John B.; McIntyre, Dale C.; Neau, Eugene L.; Stinnett, Regan W.
1996-01-01
A method and apparatus for treating material surfaces using a repetitively pulsed ion beam. In particular, a method of treating magnetic material surfaces in order to reduce surface defects, and produce amorphous fine grained magnetic material with properties that can be tailored by adjusting treatment parameters of a pulsed ion beam. In addition to a method of surface treating materials for wear and corrosion resistance using pulsed particle ion beams.
Solid lithium ion conducting electrolytes and methods of preparation
Narula, Chaitanya K; Daniel, Claus
2013-05-28
A composition comprised of nanoparticles of lithium ion conducting solid oxide material, wherein the solid oxide material is comprised of lithium ions, and at least one type of metal ion selected from pentavalent metal ions and trivalent lanthanide metal ions. Solution methods useful for synthesizing these solid oxide materials, as well as precursor solutions and components thereof, are also described. The solid oxide materials are incorporated as electrolytes into lithium ion batteries.
Solid lithium ion conducting electrolytes and methods of preparation
Narula, Chaitanya K.; Daniel, Claus
2015-11-19
A composition comprised of nanoparticles of lithium ion conducting solid oxide material, wherein the solid oxide material is comprised of lithium ions, and at least one type of metal ion selected from pentavalent metal ions and trivalent lanthanide metal ions. Solution methods useful for synthesizing these solid oxide materials, as well as precursor solutions and components thereof, are also described. The solid oxide materials are incorporated as electrolytes into lithium ion batteries.
Johnson, Ian D; Loveridge, Melanie; Bhagat, Rohit; Darr, Jawwad A
2016-11-14
A series of LiMn 1-x-y Fe x V y PO 4 (LMFVP) nanomaterials have been synthesized using a pilot-scale continuous hydrothermal synthesis process (CHFS) and evaluated as high voltage cathodes in Li-ion batteries at a production rate of 0.25 kg h -1 . The rapid synthesis and screening approach has allowed the specific capacity of the high Mn content olivines to be optimized, particularly at high discharge rates. Consistent and gradual changes in the structure and performance are observed across the compositional region under investigation; the doping of Fe at 20 at% (with respect to Mn) into lithium manganese phosphate, rather than V or indeed codoping of Fe and V, gives the best balance of high capacity and high rate performance.
Ewing, Robert G.; Atkinson, David A.; Clowers, Brian H.
2015-09-01
A method for selective detection of volatile and non-volatile explosives in a mass spectrometer or ion mobility spectrometer at a parts-per-quadrillion level without preconcentration is disclosed. The method comprises the steps of ionizing a carrier gas with an ionization source to form reactant ions or reactant adduct ions comprising nitrate ions (NO.sub.3.sup.-); selectively reacting the reactant ions or reactant adduct ions with at least one volatile or non-volatile explosive analyte at a carrier gas pressure of at least about 100 Ton in a reaction region disposed between the ionization source and an ion detector, the reaction region having a length which provides a residence time (tr) for reactant ions therein of at least about 0.10 seconds, wherein the selective reaction yields product ions comprising reactant ions or reactant adduct ions that are selectively bound to the at least one explosive analyte when present therein; and detecting product ions with the ion detector to determine presence or absence of the at least one explosive analyte.
Rydberg Molecules for Ion-Atom Scattering in the Ultracold Regime
NASA Astrophysics Data System (ADS)
Schmid, T.; Veit, C.; Zuber, N.; Löw, R.; Pfau, T.; Tarana, M.; Tomza, M.
2018-04-01
We propose a novel experimental method to extend the investigation of ion-atom collisions from the so far studied cold, essentially classical regime to the ultracold, quantum regime. The key aspect of this method is the use of Rydberg molecules to initialize the ultracold ion-atom scattering event. We exemplify the proposed method with the lithium ion-atom system, for which we present simulations of how the initial Rydberg molecule wave function, freed by photoionization, evolves in the presence of the ion-atom scattering potential. We predict bounds for the ion-atom scattering length from ab initio calculations of the interaction potential. We demonstrate that, in the predicted bounds, the scattering length can be experimentally determined from the velocity of the scattered wave packet in the case of 6Li+ = 6Li and from the molecular ion fraction in the case of 7Li+ - 7Li. The proposed method to utilize Rydberg molecules for ultracold ion-atom scattering, here particularized for the lithium ion-atom system, is readily applicable to other ion-atom systems as well.
Rydberg Molecules for Ion-Atom Scattering in the Ultracold Regime.
Schmid, T; Veit, C; Zuber, N; Löw, R; Pfau, T; Tarana, M; Tomza, M
2018-04-13
We propose a novel experimental method to extend the investigation of ion-atom collisions from the so far studied cold, essentially classical regime to the ultracold, quantum regime. The key aspect of this method is the use of Rydberg molecules to initialize the ultracold ion-atom scattering event. We exemplify the proposed method with the lithium ion-atom system, for which we present simulations of how the initial Rydberg molecule wave function, freed by photoionization, evolves in the presence of the ion-atom scattering potential. We predict bounds for the ion-atom scattering length from ab initio calculations of the interaction potential. We demonstrate that, in the predicted bounds, the scattering length can be experimentally determined from the velocity of the scattered wave packet in the case of ^{6}Li^{+}-^{6}Li and from the molecular ion fraction in the case of ^{7}Li^{+}-^{7}Li. The proposed method to utilize Rydberg molecules for ultracold ion-atom scattering, here particularized for the lithium ion-atom system, is readily applicable to other ion-atom systems as well.
Metcalfe, David; Rockey, Chris; Jefferson, Bruce; Judd, Simon; Jarvis, Peter
2015-12-15
This investigation aimed to compare the disinfection by-product formation potentials (DBPFPs) of three UK surface waters (1 upland reservoir and 2 lowland rivers) with differing characteristics treated by (a) a full scale conventional process and (b) pilot scale processes using a novel suspended ion exchange (SIX) process and inline coagulation (ILCA) followed by ceramic membrane filtration (CMF). Liquid chromatography-organic carbon detection analysis highlighted clear differences between the organic fractions removed by coagulation and suspended ion exchange. Pretreatments which combined SIX and coagulation resulted in significant reductions in dissolved organic carbon (DOC), UV absorbance (UVA), trihalomethane and haloacetic acid formation potential (THMFP, HAAFP), in comparison with the SIX or coagulation process alone. Further experiments showed that in addition to greater overall DOC removal, the processes also reduced the concentration of brominated DBPs and selectively removed organic compounds with high DBPFP. The SIX/ILCA/CMF process resulted in additional removals of DOC, UVA, THMFP, HAAFP and brominated DBPs of 50, 62, 62, 62% and 47% respectively compared with conventional treatment. Copyright © 2015. Published by Elsevier Ltd.
Single pilot IFR operating problems determined from accidental data analysis
NASA Technical Reports Server (NTRS)
Forsyth, D. L.; Shaughnessy, J. D.
1978-01-01
The accident reports examined were restricted to instrument rated pilots flying in IFR weather. A brief examination was made of accidents which occurred during all phases of flight and which were due to all causes. A detailed examination was made of those accidents which involved a single pilot which occurred during the landing phases of flight, and were due to pilot error. Problem areas found include: (1) landing phase operations especially final approach, (2) pilot weather briefings, (3) night approaches in low IFR weather, (4) below minimum approaches, (5) aircraft icing, (6) imprecise navigation, (7) descending below minimum IFR altitudes, (8) fuel mismanagement, (9) pilot overconfidence, and (10) high pilot workload especially in twins. Some suggested areas of research included: (1) low cost deicing systems, (2) standardized navigation displays, (3) low cost low-altitude warning systems, (4) improved fuel management systems, (5) improved ATC communications, (6) more effective pilot training and experience acquisition methods, and (7) better weather data dissemination techniques.
Brain biomarkers based assessment of cognitive workload in pilots under various task demands.
Gentili, Rodolphe J; Rietschel, Jeremy C; Jaquess, Kyle J; Lo, Li-Chuan; Prevost, Michael; Miller, Matt W; Mohler, Jessica M; Oh, Hyuk; Tan, Ying Ying; Hatfield, Bradley D
2014-01-01
Cognitive workload is an important element of cognitive-motor performance such as that exhibited during the piloting of an aircraft. Namely, an increase in task demands on the pilot can elevate cognitive information processing and, thus, the risk of human error. As such, there is a need to develop methods that reliably assess mental workload in pilots within operational settings. The present study contributes to this research goal by identifying physiological and brain biomarkers of cognitive workload and attentional reserve during a simulated aircraft piloting task under three progressive levels of challenge. A newly developed experimental method was employed by which electroencephalography (EEG) was acquired via a dry (i.e., gel-free sensors) system using few scalp sites. Self-reported responses to surveys and piloting performance indicators were analyzed. The findings revealed that as the challenge (task demands) increased, the perceived mental load increased, attentional reserve was attenuated, and task performance decreased. Such an increase in task demands was also reflected by changes in heart rate variability (HRV), as well as in the amplitude of the P300 component of event-related potentials to auditory probes, and in the spectral power of specific EEG frequency bands. This work provides a first step towards a long-term goal to develop a composite system of biomarkers for real-time cognitive workload assessment and state assessment of pilots in operational settings.
Careers of Professional Staff in Australian and UK Universities: A Mixed Methods Pilot Study
ERIC Educational Resources Information Center
Gander, Michelle
2017-01-01
This article confirms the reliability of a protean and boundaryless career attitudes scale, tested in a pilot study. Additionally, it summarises the results of this study into the career attitudes of professional staff in Australian and UK universities. A mixed methods approach was taken using a survey consisting of both closed questions on a…
Validation of an Instrument to Measure High School Students' Attitudes toward Fitness Testing
ERIC Educational Resources Information Center
Mercier, Kevin; Silverman, Stephen
2014-01-01
Purpose: The purpose of this investigation was to develop an instrument that has scores that are valid and reliable for measuring students' attitudes toward fitness testing. Method: The method involved the following steps: (a) an elicitation study, (b) item development, (c) a pilot study, and (d) a validation study. The pilot study included 427…
NASA Astrophysics Data System (ADS)
Farmanfarmaei, B.; Yousefi, H. R.; Salem, M. K.; Sari, A. H.
2018-04-01
The results of an experimental study of pre-ionization and heavy gas introduced into driven gas in a plasma focus device are reported. To achieve this purpose, we made use of two methods: first, the pre-ionization method by applying the shunt resistor and second, the admixture of heavy ions. We applied the different shunt resistors and found the optimum amount to be 200 MΩ at an optimum pressure of 0.5 Torr. Ion yield that was measured by array of Faraday cups and the energy of fast ions that was calculated by using the time-of-flight method were raised up to 22% and 45%, and the impurity caused by anode's erosion was reduced approximately by 67% in comparison to when there was no pre-ionization. Also, we have used the admixture of 5% argon ions with nitrogen (working gas) to improve the ion yield up to 45% in comparison with pure nitrogen. Finally, for the first time, we have utilized the combination of these methods together and have, consequently, reached the maximum ion yield and fusion yield. With this new method, ion yield raised up to 70% greater than that of the previous condition, i.e., without pre-ionization and heavy ion admixture.
Electrochemical ion separation in molten salts
Spoerke, Erik David; Ihlefeld, Jon; Waldrip, Karen; Wheeler, Jill S.; Brown-Shaklee, Harlan James; Small, Leo J.; Wheeler, David R.
2017-12-19
A purification method that uses ion-selective ceramics to electrochemically filter waste products from a molten salt. The electrochemical method uses ion-conducting ceramics that are selective for the molten salt cations desired in the final purified melt, and selective against any contaminant ions. The method can be integrated into a slightly modified version of the electrochemical framework currently used in pyroprocessing of nuclear wastes.
Liang, Longwei; Sun, Xuan; Wu, Chen; Hou, Linrui; Sun, Jinfeng; Zhang, Xiaogang; Yuan, Changzhou
2018-02-14
Surface modifications are established well as efficient methodologies to enhance comprehensive Li-storage behaviors of the cathodes and play a significant role in cutting edge innovations toward lithium-ion batteries (LIBs). Herein, we first logically devised a pilot-scale coating strategy to integrate solid-state electrolyte NaTi 2 (PO 4 ) 3 (NTP) and layered LiNi 0.5 Mn 0.3 Co 0.2 O 2 (NMC) for smart construction of core-shell NMC@NTP cathodes. The Nasicon-type NTP nanoshell with exceptional ion conductivity effectively suppressed gradual encroachment and/or loss of electroactive NMC, guaranteed stable phase interfaces, and meanwhile rendered small sur-/interfacial electron/ion-diffusion resistance. By benefiting from immanently promoting contributions of the nano-NTP coating, the as-fabricated core-shell NMC@NTP architectures were competitively endowed with superior high-voltage cyclic stabilities and rate capacities within larger electrochemical window from 3.0 to 4.6 V when utilized as advanced cathodes for advanced LIBs. More meaningfully, the appealing electrode design concept proposed here will exert significant impact upon further constructing other high-voltage Ni-based cathodes for high-energy/power LIBs.
ERIC Educational Resources Information Center
Rafferty, Karen; Zipay, Diane; Patey, Camellia; Meyer, Jennifer
2009-01-01
Purpose/Objectives: The objective of the School Milk Pilot Test and the Westside School Milk Pilot Study was to test the effect of a milk enhancement initiative to make milk more appealing and attractive to elementary and secondary school students and to improve milk consumption. Methods: 146 schools participated in the national School Milk Pilot…
NASA Astrophysics Data System (ADS)
Harper, Conner C.; Elliott, Andrew G.; Lin, Haw-Wei; Williams, Evan R.
2018-06-01
A general method for in situ measurements of the energy of individual ions trapped and weighed using charge detection mass spectrometry (CDMS) is described. Highly charged (> 300 e), individual polyethylene glycol (PEG) ions are trapped and oscillate within an electrostatic trap, producing a time domain signal. A segmented Fourier transform (FT) of this signal yields the temporal evolution of the fundamental and harmonic frequencies of ion motion throughout the 500-ms trap time. The ratio of the fundamental frequency and second harmonic (HAR) depends on the ion energy, which is an essential parameter for measuring ion mass in CDMS. This relationship is calibrated using simulated ion signals, and the calibration is compared to the HAR values measured for PEG ion signals where the ion energy was also determined using an independent method that requires that the ions be highly charged (> 300 e). The mean error of 0.6% between the two measurements indicates that the HAR method is an accurate means of ion energy determination that does not depend on ion size or charge. The HAR is determined dynamically over the entire trapping period, making it possible to observe the change in ion energy that takes place as solvent evaporates from the ion and collisions with background gas occur. This method makes it possible to measure mass changes, either from solvent evaporation or from molecular fragmentation (MSn), as well as the cross sections of ions measured using CDMS.
Infrared Ion Spectroscopy at Felix: Applications in Peptide Dissociation and Analytical Chemistry
NASA Astrophysics Data System (ADS)
Oomens, Jos
2016-06-01
Infrared free electron lasers such as those in Paris, Berlin and Nijmegen have been at the forefront of the development of infrared ion spectroscopy. In this contribution, I will give an overview of new developments in IR spectroscopy of stored ions at the FELIX Laboratory. In particular, I will focus on recent developments made possible by the coupling of a new commercial ion trap mass spectrometer to the FELIX beamline. The possibility to record IR spectra of mass-selected molecular ions and their reaction products has in recent years shed new light on our understanding of collision induced dissociation (CID) reactions of protonated peptides in mass spectrometry (MS). We now show that it is possible to record IR spectra for the products of electron transfer dissociation (ETD) reactions [M + nH]n+ + A- → [M + nH](n-1)+ + A → {dissociation of analyte} These reactions are now widely used in novel MS-based protein sequencing strategies, but involve complex radical chemistry. The spectroscopic results allow stringent verification of computationally predicted product structures and hence reaction mechanisms and H-atom migration. The sensitivity and high dynamic range of a commercial mass spectrometer also allows us to apply infrared ion spectroscopy to analytes in complex "real-life" mixtures. The ability to record IR spectra with the sensitivity of mass-spectrometric detection is unrivalled in analytical sciences and is particularly useful in the identification of small (biological) molecules, such as in metabolomics. We report preliminary results of a pilot study on the spectroscopic identification of small metabolites in urine and plasma samples.
Model-Based Systems Engineering Pilot Program at NASA Langley
NASA Technical Reports Server (NTRS)
Vipavetz, Kevin G.; Murphy, Douglas G.; Infeld, Samatha I.
2012-01-01
NASA Langley Research Center conducted a pilot program to evaluate the benefits of using a Model-Based Systems Engineering (MBSE) approach during the early phase of the Materials International Space Station Experiment-X (MISSE-X) project. The goal of the pilot was to leverage MBSE tools and methods, including the Systems Modeling Language (SysML), to understand the net gain of utilizing this approach on a moderate size flight project. The System Requirements Review (SRR) success criteria were used to guide the work products desired from the pilot. This paper discusses the pilot project implementation, provides SysML model examples, identifies lessons learned, and describes plans for further use on MBSE on MISSE-X.
NASA Astrophysics Data System (ADS)
Thomas, M. A.
2016-12-01
The Waste Isolation Pilot Plant (WIPP) is the only deep geological repository for transuranic waste in the United States. As the Science Advisor for the WIPP, Sandia National Laboratories annually evaluates site data against trigger values (TVs), metrics whose violation is indicative of conditions that may impact long-term repository performance. This study focuses on a groundwater-quality dataset used to redesign a TV for the Culebra Dolomite Member (Culebra) of the Permian-age Rustler Formation. Prior to this study, a TV violation occurred if the concentration of a major ion fell outside a range defined as the mean +/- two standard deviations. The ranges were thought to denote conditions that 95% of future values would fall within. Groundwater-quality data used in evaluating compliance, however, are rarely normally distributed. To create a more robust Culebra groundwater-quality TV, this study employed the randomization test, a non-parametric permutation method. Recent groundwater compositions considered TV violations under the original ion concentration ranges are now interpreted as false positives in light of the insignificant p-values calculated with the randomization test. This work highlights that the normality assumption can weaken as the size of a groundwater-quality dataset grows over time. Non-parametric permutation methods are an attractive option because no assumption about the statistical distribution is required and calculating all combinations of the data is an increasingly tractable problem with modern workstations. Sandia National Laboratories is a multi-program laboratory managed and operated by Sandia Corporation, a wholly owned subsidiary of Lockheed Martin Corporation, for the U.S. Department of Energy's National Nuclear Security Administration under contract DE-AC04-94AL85000. This research is funded by WIPP programs administered by the Office of Environmental Management (EM) of the U.S. Department of Energy. SAND2016-7306A
Ion-ion dynamic structure factor of warm dense mixtures
Gill, N. M.; Heinonen, R. A.; Starrett, C. E.; ...
2015-06-25
In this study, the ion-ion dynamic structure factor of warm dense matter is determined using the recently developed pseudoatom molecular dynamics method [Starrett et al., Phys. Rev. E 91, 013104 (2015)]. The method uses density functional theory to determine ion-ion pair interaction potentials that have no free parameters. These potentials are used in classical molecular dynamics simulations. This constitutes a computationally efficient and realistic model of dense plasmas. Comparison with recently published simulations of the ion-ion dynamic structure factor and sound speed of warm dense aluminum finds good to reasonable agreement. Using this method, we make predictions of the ion-ionmore » dynamical structure factor and sound speed of a warm dense mixture—equimolar carbon-hydrogen. This material is commonly used as an ablator in inertial confinement fusion capsules, and our results are amenable to direct experimental measurement.« less
Context-Aware Intelligent Assistant Approach to Improving Pilot's Situational Awareness
NASA Technical Reports Server (NTRS)
Spirkovska, Lilly; Lodha, Suresh K.
2004-01-01
Faulty decision making due to inaccurate or incomplete awareness of the situation tends to be the prevailing cause of fatal general aviation accidents. Of these accidents, loss of weather situational awareness accounts for the largest number of fatalities. We describe a method for improving weather situational awareness through the support of a contextaware,domain and task knowledgeable, personalized and adaptive assistant. The assistant automatically monitors weather reports for the pilot's route of flight and warns her of detected anomalies. When and how warnings are issued is determined by phase of flight, the pilot s definition of acceptable weather conditions, and the pilot's preferences for automatic notification. In addition to automatic warnings, the pilot is able to verbally query for weather and airport information. By noting the requests she makes during the approach phase of flight, our system learns to provide the information without explicit requests on subsequent flights with similar conditions. We show that our weather assistant decreases the effort required to maintain situational awareness by more than 5.5 times when compared to the conventional method of in-flight weather briefings.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Muto, Hideshi; Ohshiro, Yukimitsu; Kawasaki, Katsunori
2013-04-19
In the past decade, we have developed extremely long-lived carbon stripper foils of 1-50 {mu}g/cm{sup 2} thickness prepared by a heavy ion beam sputtering method. These foils were mainly used for low energy heavy ion beams. Recently, high energy negative Hydrogen and heavy ion accelerators have started to use carbon stripper foils of over 100 {mu}g/cm{sup 2} in thickness. However, the heavy ion beam sputtering method was unsuccessful in production of foils thicker than about 50 {mu}g/cm{sup 2} because of the collapse of carbon particle build-up from substrates during the sputtering process. The reproduction probability of the foils was lessmore » than 25%, and most of them had surface defects. However, these defects were successfully eliminated by introducing higher beam energies of sputtering ions and a substrate heater during the sputtering process. In this report we describe a highly reproducible method for making thick carbon stripper foils by a heavy ion beam sputtering with a Krypton ion beam.« less
User's manual: Subsonic/supersonic advanced panel pilot code
NASA Technical Reports Server (NTRS)
Moran, J.; Tinoco, E. N.; Johnson, F. T.
1978-01-01
Sufficient instructions for running the subsonic/supersonic advanced panel pilot code were developed. This software was developed as a vehicle for numerical experimentation and it should not be construed to represent a finished production program. The pilot code is based on a higher order panel method using linearly varying source and quadratically varying doublet distributions for computing both linearized supersonic and subsonic flow over arbitrary wings and bodies. This user's manual contains complete input and output descriptions. A brief description of the method is given as well as practical instructions for proper configurations modeling. Computed results are also included to demonstrate some of the capabilities of the pilot code. The computer program is written in FORTRAN IV for the SCOPE 3.4.4 operations system of the Ames CDC 7600 computer. The program uses overlay structure and thirteen disk files, and it requires approximately 132000 (Octal) central memory words.
Enhanced DOC removal using anion and cation ion exchange resins.
Arias-Paic, Miguel; Cawley, Kaelin M; Byg, Steve; Rosario-Ortiz, Fernando L
2016-01-01
Hardness and DOC removal in a single ion exchange unit operation allows for less infrastructure, is advantageous for process operation and depending on the water source, could enhance anion exchange resin removal of dissolved organic carbon (DOC). Simultaneous application of cationic (Plus) and anionic (MIEX) ion exchange resin in a single contact vessel was tested at pilot and bench scales, under multiple regeneration cycles. Hardness removal correlated with theoretical predictions; where measured hardness was between 88 and 98% of the predicted value. Comparing bench scale DOC removal of solely treating water with MIEX compared to Plus and MIEX treated water showed an enhanced DOC removal, where removal was increased from 0.5 to 1.25 mg/L for the simultaneous resin application compared to solely applying MIEX resin. A full scale MIEX treatment plant (14.5 MGD) reduced raw water DOC from 13.7 mg/L to 4.90 mg/L in the treated effluent at a bed volume (BV) treatment rate of 800, where a parallel operation of a simultaneous MIEX and Plus resin pilot (10 gpm) measured effluent DOC concentrations of no greater than 3.4 mg/L, even at bed volumes of treatment 37.5% greater than the full scale plant. MIEX effluent compared to simultaneous Plus and MIEX effluent resulted in differences in fluorescence intensity that correlated to decreases in DOC concentration. The simultaneous treatment of Plus and MIEX resin produced water with predominantly microbial character, indicating the enhanced DOC removal was principally due to increased removal of terrestrially derived organic matter. The addition of Plus resin to a process train with MIEX resin allows for one treatment process to remove both DOC and hardness, where a single brine waste stream can be sent to sewer at a full-scale plant, completely removing lime chemical addition and sludge waste disposal for precipitative softening processes. Published by Elsevier Ltd.
Ion source for high-precision mass spectrometry
Todd, Peter J.; McKown, Henry S.; Smith, David H.
1984-01-01
The invention is directed to a method for increasing the precision of positive-ion relative abundance measurements conducted in a sector mass spectrometer having an ion source for directing a beam of positive ions onto a collimating slit. The method comprises incorporating in the source an electrostatic lens assembly for providing a positive-ion beam of circular cross section for collimation by the slit.
Streaming potentials in gramicidin channels measured with ion-selective microelectrodes.
Tripathi, S; Hladky, S B
1998-01-01
Streaming potentials have been measured for gramicidin channels with a new method employing ion-selective microelectrodes. It is shown that ideally ion-selective electrodes placed at the membrane surface record the true streaming potential. Using this method for ion concentrations below 100 mM, approximately seven water molecules are transported whenever a sodium, potassium, or cesium ion, passes through the channel. This new method confirms earlier measurements (Rosenberg, P.A., and A. Finkelstein. 1978. Interaction of ions and water in gramicidin A channels. J. Gen. Physiol. 72:327-340) in which the streaming potentials were calculated as the difference between electrical potentials measured in the presence of gramicidin and in the presence of the ion carriers valinomycin and nonactin. PMID:9635745
ERIC Educational Resources Information Center
Senra, Hugo
2013-01-01
The current pilot study aims to explore whether different adults' experiences of lower-limb amputation could be associated with different levels of depression. To achieve these study objectives, a convergent parallel mixed methods design was used in a convenience sample of 42 adult amputees (mean age of 61 years; SD = 13.5). All of them had…
ERIC Educational Resources Information Center
Humphries, Kathleen; Traci, Meg Ann; Seekins, Tom
2008-01-01
Background: Adults with intellectual or developmental disabilities need dietary monitoring but are not likely to be able to provide accurate dietary intake data via traditional methods. Pilot study efforts to meet their support needs with a novel and practical approach to dietary intake data collection are described in this brief report. Materials…
A Pilot Study on the Potential Use of Tomatis Method to Improve L2 Reading Fluency
ERIC Educational Resources Information Center
Chou, Peter Tze-Ming
2012-01-01
This was a pilot study that used the Tomatis Method to see the effects it had on L2 reading fluency in a group of Taiwanese learners. Eight volunteers participated in this study undertaking 40-hours of before-and-after-experimental treatments. The results from the analysis showed that the participants had significant improvements in the areas of…
ERIC Educational Resources Information Center
Mackay, Bethany A.; Shochet, Ian M.; Orr, Jayne A.
2017-01-01
Despite increased depression in adolescents with Autism Spectrum Disorder (ASD), effective prevention approaches for this population are limited. A mixed methods pilot randomised controlled trial (N = 29) of the evidence-based Resourceful Adolescent Program-Autism Spectrum Disorder (RAP-A-ASD) designed to prevent depression was conducted in…
Sim, Julius; Lewis, Martyn
2012-03-01
To investigate methods to determine the size of a pilot study to inform a power calculation for a randomized controlled trial (RCT) using an interval/ratio outcome measure. Calculations based on confidence intervals (CIs) for the sample standard deviation (SD). Based on CIs for the sample SD, methods are demonstrated whereby (1) the observed SD can be adjusted to secure the desired level of statistical power in the main study with a specified level of confidence; (2) the sample for the main study, if calculated using the observed SD, can be adjusted, again to obtain the desired level of statistical power in the main study; (3) the power of the main study can be calculated for the situation in which the SD in the pilot study proves to be an underestimate of the true SD; and (4) an "efficient" pilot size can be determined to minimize the combined size of the pilot and main RCT. Trialists should calculate the appropriate size of a pilot study, just as they should the size of the main RCT, taking into account the twin needs to demonstrate efficiency in terms of recruitment and to produce precise estimates of treatment effect. Copyright © 2012 Elsevier Inc. All rights reserved.
MIVOC method with temperature controla)
NASA Astrophysics Data System (ADS)
Takasugi, W.; Wakaisami, M.; Sasaki, N.; Sakuma, T.; Yamamoto, M.; Kitagawa, A.; Muramatsu, M.
2010-02-01
The Heavy Ion Medical Accelerator in Chiba at the National Institute of Radiological Sciences has been used for cancer therapy, physics, and biology experiments since 1994. Its ion sources produce carbon ion for cancer therapy. They also produce various ions (H+-Xe21+) for physics and biology experiments. Most ion species are produced from gases by an 18 GHz electron cyclotron resonance ion source. However, some of ion species is difficult to produce from stable and secure gases. Such ion species are produced by the sputtering method. However, it is necessary to reduce material consumption rate as much as possible in the case of rare and expensive stable isotopes. We have selected "metal ions from volatile compounds method" as a means to solve this problem. We tested a variety of compounds. Since each compound has a suitable temperature to obtain the optimum vapor pressure, we have developed an accurate temperature control system. We have produced ions such as F58e9+, Co9+, Mg5+, Ti10+, Si5+, and Ge12+ with the temperature control.
Harper, Conner C; Elliott, Andrew G; Lin, Haw-Wei; Williams, Evan R
2018-06-02
A general method for in situ measurements of the energy of individual ions trapped and weighed using charge detection mass spectrometry (CDMS) is described. Highly charged (> 300 e), individual polyethylene glycol (PEG) ions are trapped and oscillate within an electrostatic trap, producing a time domain signal. A segmented Fourier transform (FT) of this signal yields the temporal evolution of the fundamental and harmonic frequencies of ion motion throughout the 500-ms trap time. The ratio of the fundamental frequency and second harmonic (HAR) depends on the ion energy, which is an essential parameter for measuring ion mass in CDMS. This relationship is calibrated using simulated ion signals, and the calibration is compared to the HAR values measured for PEG ion signals where the ion energy was also determined using an independent method that requires that the ions be highly charged (> 300 e). The mean error of 0.6% between the two measurements indicates that the HAR method is an accurate means of ion energy determination that does not depend on ion size or charge. The HAR is determined dynamically over the entire trapping period, making it possible to observe the change in ion energy that takes place as solvent evaporates from the ion and collisions with background gas occur. This method makes it possible to measure mass changes, either from solvent evaporation or from molecular fragmentation (MS n ), as well as the cross sections of ions measured using CDMS. Graphical Abstract.
Ion Move Brownian Dynamics (IMBD)--simulations of ion transport.
Kurczynska, Monika; Kotulska, Malgorzata
2014-01-01
Comparison of the computed characteristics and physiological measurement of ion transport through transmembrane proteins could be a useful method to assess the quality of protein structures. Simulations of ion transport should be detailed but also timeefficient. The most accurate method could be Molecular Dynamics (MD), which is very time-consuming, hence is not used for this purpose. The model which includes ion-ion interactions and reduces the simulation time by excluding water, protein and lipid molecules is Brownian Dynamics (BD). In this paper a new computer program for BD simulation of the ion transport is presented. We evaluate two methods for calculating the pore accessibility (round and irregular shape) and two representations of ion sizes (van der Waals diameter and one voxel). Ion Move Brownian Dynamics (IMBD) was tested with two nanopores: alpha-hemolysin and potassium channel KcsA. In both cases during the simulation an ion passed through the pore in less than 32 ns. Although two types of ions were in solution (potassium and chloride), only ions which agreed with the selectivity properties of the channels passed through the pores. IMBD is a new tool for the ion transport modelling, which can be used in the simulations of wide and narrow pores.
Reactive ion etched substrates and methods of making and using
Rucker, Victor C [San Francisco, CA; Shediac, Rene [Oakland, CA; Simmons, Blake A [San Francisco, CA; Havenstrite, Karen L [New York, NY
2007-08-07
Disclosed herein are substrates comprising reactive ion etched surfaces and specific binding agents immobilized thereon. The substrates may be used in methods and devices for assaying or isolating analytes in a sample. Also disclosed are methods of making the reactive ion etched surfaces.
Pace, Romina; Pluye, Pierre; Bartlett, Gillian; Macaulay, Ann C; Salsberg, Jon; Jagosh, Justin; Seller, Robbyn
2012-01-01
Systematic literature reviews identify, select, appraise, and synthesize relevant literature on a particular topic. Typically, these reviews examine primary studies based on similar methods, e.g., experimental trials. In contrast, interest in a new form of review, known as mixed studies review (MSR), which includes qualitative, quantitative, and mixed methods studies, is growing. In MSRs, reviewers appraise studies that use different methods allowing them to obtain in-depth answers to complex research questions. However, appraising the quality of studies with different methods remains challenging. To facilitate systematic MSRs, a pilot Mixed Methods Appraisal Tool (MMAT) has been developed at McGill University (a checklist and a tutorial), which can be used to concurrently appraise the methodological quality of qualitative, quantitative, and mixed methods studies. The purpose of the present study is to test the reliability and efficiency of a pilot version of the MMAT. The Center for Participatory Research at McGill conducted a systematic MSR on the benefits of Participatory Research (PR). Thirty-two PR evaluation studies were appraised by two independent reviewers using the pilot MMAT. Among these, 11 (34%) involved nurses as researchers or research partners. Appraisal time was measured to assess efficiency. Inter-rater reliability was assessed by calculating a kappa statistic based on dichotomized responses for each criterion. An appraisal score was determined for each study, which allowed the calculation of an overall intra-class correlation. On average, it took 14 min to appraise a study (excluding the initial reading of articles). Agreement between reviewers was moderate to perfect with regards to MMAT criteria, and substantial with respect to the overall quality score of appraised studies. The MMAT is unique, thus the reliability of the pilot MMAT is promising, and encourages further development. Copyright © 2011 Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Arinbasarov, M.U.; Murygina, V.P.; Mats, A.A.
1995-12-31
The pilot area of the Vyngapour oil field allotted for MIOR tests contains three injection and three producing wells. These wells were treated in summer 1993 and 1994. Before, during, and after MIOR treatments on the pilot area the chemical compounds of injected and formation waters were studied, as well as the amount and species of microorganisms entering the stratum with the injected water and indigenous bacteria presented in bottomhole zones of the wells. The results of monitoring showed that the bottomhole zone of the injection well already had biocenosis of heterotrophic, hydrocarbon-oxidizing, methanogenic, and sulfate-reducing bacteria, which were besidesmore » permanently introduced into the reservoir during the usual waterflooding. The nutritious composition activated vital functions of all bacterial species presented in the bottomhole zone of the injection well. The formation waters from producing wells showed the increase of the content of nitrate, sulfate, phosphate, and bicarbonate ions by the end of MIOR. The amount of hydrocarbon-oxidizing bacteria in formation waters of producing wells increased by one order. The chemical and biological monitoring revealed the activation of the formation microorganisms, but no transport of food industry waste bacteria through the formation from injection to producing wells was found.« less
Crew workload-management strategies - A critical factor in system performance
NASA Technical Reports Server (NTRS)
Hart, Sandra G.
1989-01-01
This paper reviews the philosophy and goals of the NASA/USAF Strategic Behavior/Workload Management Program. The philosophical foundation of the program is based on the assumption that an improved understanding of pilot strategies will clarify the complex and inconsistent relationships observed among objective task demands and measures of system performance and pilot workload. The goals are to: (1) develop operationally relevant figures of merit for performance, (2) quantify the effects of strategic behaviors on system performance and pilot workload, (3) identify evaluation criteria for workload measures, and (4) develop methods of improving pilots' abilities to manage workload extremes.
Method and apparatus for time dispersive spectroscopy
Tarver, III, Edward E.; Siems, William F.
2003-06-17
Methods and apparatus are described for time dispersive spectroscopy. In particular, a modulated flow of ionized molecules of a sample are introduced into a drift region of an ion spectrometer. The ions are subsequently detected by an ion detector to produce an ion detection signal. The ion detection signal can be modulated to obtain a signal useful in assaying the chemical constituents of the sample.
Ion source for high-precision mass spectrometry
Todd, P.J.; McKown, H.S.; Smith, D.H.
1982-04-26
The invention is directed to a method for increasing the precision of positive-ion relative abundance measurements conducted in a sector mass spectrometer having an ion source for directing a beam of positive ions onto a collimating slit. The method comprises incorporating in the source an electrostatic lens assembly for providing a positive-ion beam of circular cross section for collimation by the slit. 2 figures, 3 tables.
Mass spectrometer and methods of increasing dispersion between ion beams
Appelhans, Anthony D.; Olson, John E.; Delmore, James E.
2006-01-10
A mass spectrometer includes a magnetic sector configured to separate a plurality of ion beams, and an electrostatic sector configured to receive the plurality of ion beams from the magnetic sector and increase separation between the ion beams, the electrostatic sector being used as a dispersive element following magnetic separation of the plurality of ion beams. Other apparatus and methods are provided.
Ryu, Shoraku; Hayashi, Mitsuhiro; Aikawa, Hiroaki; Okamoto, Isamu; Fujiwara, Yasuhiro; Hamada, Akinobu
2018-01-01
The penetration of the anaplastic lymphoma kinase (ALK) inhibitor alectinib in neuroblastomas and the relationship between alectinib and ALK expression are unknown. The aim of this study was to perform a quantitative investigation of the inter- and intra-tumoural distribution of alectinib in different neuroblastoma xenograft models using matrix-assisted laser desorption ionization MS imaging (MALDI-MSI). The distribution of alectinib in NB1 (ALK amplification) and SK-N-FI (ALK wild-type) xenograft tissues was analysed using MALDI-MSI. The abundance of alectinib in tumours and intra-tumoural areas was quantified using ion signal intensities from MALDI-MSI after normalization by correlation with LC-MS/MS. The distribution of alectinib was heterogeneous in neuroblastomas. The penetration of alectinib was not significantly different between ALK amplification and ALK wide-type tissues using both LC-MS/MS concentrations and MSI intensities. Normalization with an internal standard increased the quantitative property of MSI by adjusting for the ion suppression effect. The distribution of alectinib in different intra-tumoural areas can alternatively be quantified from MS images by correlation with LC-MS/MS. The penetration of alectinib into tumour tissues may not be homogenous or influenced by ALK expression in the early period after single-dose administration. MALDI-MSI may prove to be a valuable pharmaceutical method for elucidating the mechanism of action of drugs by clarifying their microscopic distribution in heterogeneous tissues. © 2017 The British Pharmacological Society.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ma, L.; Zhao, H.W.; Cao, Y.
2005-03-15
Two new space charge compensation methods developed in IMP are discussed in this paper. There are negative high voltage electrode method (NHVEM) and electronegative charge gas method (EGM). Some valuable experimental data have been achieved, especially using electronegative gas method in O6+ and O7+ dramatic and stable increasing of ion current was observed.
Stall Recovery Guidance Algorithms Based on Constrained Control Approaches
NASA Technical Reports Server (NTRS)
Stepanyan, Vahram; Krishnakumar, Kalmanje; Kaneshige, John; Acosta, Diana
2016-01-01
Aircraft loss-of-control, in particular approach to stall or fully developed stall, is a major factor contributing to aircraft safety risks, which emphasizes the need to develop algorithms that are capable of assisting the pilots to identify the problem and providing guidance to recover the aircraft. In this paper we present several stall recovery guidance algorithms, which are implemented in the background without interfering with flight control system and altering the pilot's actions. They are using input and state constrained control methods to generate guidance signals, which are provided to the pilot in the form of visual cues. It is the pilot's decision to follow these signals. The algorithms are validated in the pilot-in-the loop medium fidelity simulation experiment.
A flight test method for pilot/aircraft analysis
NASA Technical Reports Server (NTRS)
Koehler, R.; Buchacker, E.
1986-01-01
In high precision flight maneuvres a pilot is a part of a closed loop pilot/aircraft system. The assessment of the flying qualities is highly dependent on the closed loop characteristics related to precision maneuvres like approach, landing, air-to-air tracking, air-to-ground tracking, close formation flying and air-to air refueling of the receiver. The object of a research program at DFVLR is the final flight phase of an air to ground mission. In this flight phase the pilot has to align the aircraft with the target, correct small deviations from the target direction and keep the target in his sights for a specific time period. To investigate the dynamic behavior of the pilot-aircraft system a special ground attack flight test technique with a prolonged tracking maneuvres was developed. By changing the targets during the attack the pilot is forced to react continously on aiming errors in his sights. Thus the closed loop pilot/aircraft system is excited over a wide frequency range of interest, the pilot gets more information about mission oriented aircraft dynamics and suitable flight test data for a pilot/aircraft analysis can be generated.
Shorey, Ryan C.; Brasfield, Hope; Anderson, Scott; Stuart, Gregory L.
2014-01-01
Background Recent research has begun to examine the early maladaptive schemas of substance abusers, as it is believed that targeting these core beliefs in treatment may result in improved substance use outcomes. One special population that has received scant attention in the research literature, despite high levels of substance use, is airline pilots. Aims The current study examined the early maladaptive schemas of a sample of airline pilots (n = 64) who were seeking residential treatment for alcohol dependence and whether they differed in early maladaptive schemas from non-pilot substance abusers who were also seeking residential treatment for alcohol dependence (n = 45). Method Pre-existing medical records from patients of a residential substance abuse treatment facility were reviewed for the current study. Results Of the 18 early maladaptive schemas, results demonstrated that pilots scored higher than non-pilots on the early maladaptive schema of unrelenting standards (high internalized standards of behavior), whereas non-pilots scored higher on insufficient self-control (low frustration tolerance and self-control). Conclusions Early maladaptive schemas may be a relevant treatment target for substance abuse treatment seeking pilots and non-pilots. PMID:24701252
METHOD AND APPARATUS FOR TRAPPING IONS IN A MAGNETIC FIELD
Luce, J.S.
1962-04-17
A method and apparatus are described for trapping ions within an evacuated container and within a magnetic field utilizing dissociation and/or ionization of molecular ions to form atomic ions and energetic neutral particles. The atomic ions are magnetically trapped as a result of a change of charge-to- mass ratio. The molecular ions are injected into the container and into the path of an energetic carbon arc discharge which dissociates and/or ionizes a portion of the molecular ions into atomic ions and energetic neutrals. The resulting atomic ions are trapped by the magnetic field to form a circulating beam of atomic ions, and the energetic neutrals pass out of the system and may be utilized in a particle accelerator. (AEC)
Ion mobility spectrometer using frequency-domain separation
Martin, Stephen J.; Butler, Michael A.; Frye, Gregory C.; Schubert, W. Kent
1998-01-01
An apparatus and method is provided for separating and analyzing chemical species in an ion mobility spectrometer using a frequency-domain technique wherein the ions generated from the chemical species are selectively transported through an ion flow channel having a moving electrical potential therein. The moving electrical potential allows the ions to be selected according to ion mobility, with certain of the ions being transported to an ion detector and other of the ions being effectively discriminated against. The apparatus and method have applications for sensitive chemical detection and analysis for monitoring of exhaust gases, hazardous waste sites, industrial processes, aerospace systems, non-proliferation, and treaty verification. The apparatus can be formed as a microelectromechanical device (i.e. a micromachine).
Developing a fatigue questionnaire for Chinese civil aviation pilots.
Dai, Jing; Luo, Min; Hu, Wendong; Ma, Jin; Wen, Zhihong
2018-03-23
To assess the fatigue risk is an important challenge in improving flight safety in aviation industry. The aim of this study was to develop a comprehensive fatigue risk management indicators system and a fatigue questionnaire for Chinese civil aviation pilots. Participants included 74 (all males) civil aviation pilots. They finished the questionnaire in 20 minutes before a flight mission. The estimation of internal consistency with Cronbach's α and Student's t test as well as Pearson's correlation analysis were the main statistical methods. The results revealed that the fatigue questionnaire had acceptable internal consistency reliability and construct validity; there were significant differences on fatigue scores between international and domestic flight pilots. And some international flight pilots, who had taken medications as a sleep aid, had worse sleep quality than those had not. The long-endurance flight across time zones caused significant differences in circadian rhythm. The fatigue questionnaire can be used to measure Chinese civil aviation pilots' fatigue, which provided a reference for fatigue risk management system to civil aviation pilots.
NASA Astrophysics Data System (ADS)
Guo, Yugao; Zhao, He; Han, Yelin; Liu, Xia; Guan, Shan; Zhang, Qingyin; Bian, Xihui
2017-02-01
A simultaneous spectrophotometric determination method for trace heavy metal ions based on solid-phase extraction coupled with partial least squares approaches was developed. In the proposed method, trace metal ions in aqueous samples were adsorbed by cation exchange fibers and desorbed by acidic solution from the fibers. After the ion preconcentration process, the enriched solution was detected by ultraviolet and visible spectrophotometer (UV-Vis). Then, the concentration of heavy metal ions were quantified by analyzing ultraviolet and visible spectrum with the help of partial least squares (PLS) approaches. Under the optimal conditions of operation time, flow rate and detection parameters, the overlapped absorption peaks of mixed ions were obtained. The experimental data showed that the concentration, which can be calculated through chemometrics method, of each metal ion increased significantly. The heavy metal ions can be enriched more than 80-fold. The limits of detection (LOD) for the target analytes of copper ions (Cu2 +), cobalt ions (Co2 +) and nickel ions (Ni2 +) mixture was 0.10 μg L- 1, 0.15 μg L- 1 and 0.13 μg L- 1, respectively. The relative standard deviations (RSD) were less than 5%. The performance of the solid-phase extraction can enrich the ions efficiently and the combined method of spectrophotometric detection and PLS can evaluate the ions concentration accurately. The work proposed here is an interesting and promising attempt for the trace ions determination in water samples and will have much more applied field.
Guo, Yugao; Zhao, He; Han, Yelin; Liu, Xia; Guan, Shan; Zhang, Qingyin; Bian, Xihui
2017-02-15
A simultaneous spectrophotometric determination method for trace heavy metal ions based on solid-phase extraction coupled with partial least squares approaches was developed. In the proposed method, trace metal ions in aqueous samples were adsorbed by cation exchange fibers and desorbed by acidic solution from the fibers. After the ion preconcentration process, the enriched solution was detected by ultraviolet and visible spectrophotometer (UV-Vis). Then, the concentration of heavy metal ions were quantified by analyzing ultraviolet and visible spectrum with the help of partial least squares (PLS) approaches. Under the optimal conditions of operation time, flow rate and detection parameters, the overlapped absorption peaks of mixed ions were obtained. The experimental data showed that the concentration, which can be calculated through chemometrics method, of each metal ion increased significantly. The heavy metal ions can be enriched more than 80-fold. The limits of detection (LOD) for the target analytes of copper ions (Cu 2+ ), cobalt ions (Co 2+ ) and nickel ions (Ni 2+ ) mixture was 0.10μgL -1 , 0.15μgL -1 and 0.13μgL -1 , respectively. The relative standard deviations (RSD) were less than 5%. The performance of the solid-phase extraction can enrich the ions efficiently and the combined method of spectrophotometric detection and PLS can evaluate the ions concentration accurately. The work proposed here is an interesting and promising attempt for the trace ions determination in water samples and will have much more applied field. Copyright © 2016 Elsevier B.V. All rights reserved.
Pilot age and expertise predict flight simulator performance
Kennedy, Quinn; Noda, Art; Yesavage, Jerome A.
2010-01-01
Background Expert knowledge may compensate for age-related declines in basic cognitive and sensory-motor abilities in some skill domains. We investigated the influence of age and aviation expertise (indexed by Federal Aviation Administration pilot ratings) on longitudinal flight simulator performance. Methods Over a 3-year period, 118 general aviation pilots aged 40 to 69 years were tested annually, in which their flight performance was scored in terms of 1) executing air-traffic controller communications; 2) traffic avoidance; 3) scanning cockpit instruments; 4) executing an approach to landing; and 5) a flight summary score. Results More expert pilots had better flight summary scores at baseline and showed less decline over time. Secondary analyses revealed that expertise effects were most evident in the accuracy of executing aviation communications, the measure on which performance declined most sharply over time. Regarding age, even though older pilots initially performed worse than younger pilots, over time older pilots showed less decline in flight summary scores than younger pilots. Secondary analyses revealed that the oldest pilots did well over time because their traffic avoidance performance improved more vs younger pilots. Conclusions These longitudinal findings support previous cross-sectional studies in aviation as well as non-aviation domains, which demonstrated the advantageous effect of prior experience and specialized expertise on older adults’ skilled cognitive performances. PMID:17325270
Carbon ion pump for removal of carbon dioxide from combustion gas and other gas mixtures
Aines, Roger D.; Bourcier, William L.
2014-08-19
A novel method and system of separating carbon dioxide from flue gas is introduced. Instead of relying on large temperature or pressure changes to remove carbon dioxide from a solvent used to absorb it from flue gas, the ion pump method, as disclosed herein, dramatically increases the concentration of dissolved carbonate ion in solution. This increases the overlying vapor pressure of carbon dioxide gas, permitting carbon dioxide to be removed from the downstream side of the ion pump as a pure gas. The ion pumping may be obtained from reverse osmosis, electrodialysis, thermal desalination methods, or an ion pump system having an oscillating flow in synchronization with an induced electric field.
Carbon ion pump for removal of carbon dioxide from combustion gas and other gas mixtures
Aines, Roger D.; Bourcier, William L.
2010-11-09
A novel method and system of separating carbon dioxide from flue gas is introduced. Instead of relying on large temperature or pressure changes to remove carbon dioxide from a solvent used to absorb it from flue gas, the ion pump method, as disclosed herein, dramatically increases the concentration of dissolved carbonate ion in solution. This increases the overlying vapor pressure of carbon dioxide gas, permitting carbon dioxide to be removed from the downstream side of the ion pump as a pure gas. The ion pumping may be obtained from reverse osmosis, electrodialysis, thermal desalination methods, or an ion pump system having an oscillating flow in synchronization with an induced electric field.
Method and apparatus for ion mobility spectrometry with alignment of dipole direction (IMS-ADD)
Shvartsburg, Alexandre A [Richland, WA; Tang, Keqi [Richland, WA; Smith, Richard D [Richland, WA
2007-01-30
Techniques and instrumentation are described for analyses of substances, including complex samples/mixtures that require separation prior to characterization of individual components. A method is disclosed for separation of ion mixtures and identification of ions, including protein and other macromolecular ions and their different structural isomers. Analyte ions are not free to rotate during the separation, but are substantially oriented with respect to the drift direction. Alignment is achieved by applying, at a particular angle to the drift field, a much stronger alternating electric field that "locks" the ion dipoles with moments exceeding a certain value. That value depends on the buffer gas composition, pressure, and temperature, but may be as low as .about.3 Debye under certain conditions. The presently disclosed method measures the direction-specific cross-sections that provide the structural information complementing that obtained from known methods, and, when coupled to those methods, increases the total peak capacity and specificity of gas-phase separations. Simultaneous 2-D separations by direction-specific cross sections along and orthogonally to the ion dipole direction are also possible.
This compilation of field collection standard operating procedures (SOPs) was assembled for the U.S. Environmental Protection Agency’s (EPA) Pilot Study add-on to the Green Housing Study (GHS). A detailed description of this add-on study can be found in the peer reviewed research...
Process for measuring degradation of sulfur hexafluoride in high voltage systems
Sauers, Isidor
1986-01-01
This invention is a method of detecting the presence of toxic and corrosive by-products in high voltage systems produced by electrically induced degradation of SF.sub.6 insulating gas in the presence of certain impurities. It is an improvement over previous methods because it is extremely sensitive, detecting by-products present in parts per billion concentrations, and because the device employed is of a simple design and takes advantage of the by-products natural affinity for fluoride ions. The method employs an ion-molecule reaction cell in which negative ions of the by-products are produced by fluorine attachment. These ions are admitted to a negative ion mass spectrometer and identified by their spectra. This spectrometry technique is an improvement over conventional techniques because the negative ion peaks are strong and not obscured by a major ion spectra of the SF.sub.6 component as is the case in positive ion mass spectrometry.
Process for measuring degradation of sulfur hexafluoride in high voltage systems
Sauers, I.
1985-04-23
This invention is a method of detecting the presence of toxic and corrosive by-products in high voltage systems produced by electrically induced degradation of SF/sub 6/ insulating gas in the presence of certain impurities. It is an improvement over previous methods because it is extremely sensitive, detecting by-products present in parts per billion concentrations, and because the device employed is of a simple design and takes advantage of the by-products natural affinity for fluoride ions. The method employs an ion-molecule reaction cell in which negative ions of the by-products are produced by fluorine attachment. These ions are admitted to a negative ion mass spectrometer and identified by their spectra. This spectrometry technique is an improvement over conventional techniques because the negative ion peaks are strong and not obscured by a major ion spectra of the SF/sub 6/ component as is the case in positive ion mass spectrometry.
About the mechanism of ERP-system pilot test
NASA Astrophysics Data System (ADS)
Mitkov, V. V.; Zimin, V. V.
2018-05-01
In the paper the mathematical problem of defining the scope of pilot test is stated, which is a task of quadratic programming. The procedure of the problem solving includes the method of network programming based on the structurally similar network representation of the criterion and constraints and which reduces the original problem to a sequence of simpler evaluation tasks. The evaluation tasks are solved by the method of dichotomous programming.
Pilot-in-the-Loop CFD Method Development
2016-02-01
Contract # N00014-14-C-0020 Pilot-in-the-Loop CFD Method Development Progress Report (CDRL A001) Progress Report for Period: October 21...of the aircraft from the rest of its external environment. For example, ship airwake are calculated using CFD solutions without the presence of the...approaches with the goal of real time, fully coupled CFD for virtual dynamic interface modeling & simulation. Penn State is supporting the project
Pilot-in-the Loop CFD Method Development
2016-04-27
Contract # N00014-14-C-0020 Pilot-in-the-Loop CFD Method Development Progress Report (CDRL A001) Progress Report for Period: January 21...aerodynamics of the aircraft from the rest of its external environment. For example, ship airwake are calculated using CFD solutions without the presence of...hardware approaches with the goal of real time, fully coupled CFD for virtual dynamic interface modeling & simulation. Penn State is supporting the project
Pilot-in-the-Loop CFD Method Development
2017-04-20
the methods on the NAVAIR Manned Flight Simulator. Activities this period During this report period, we implemented the CRAFT CFD code on the...Penn State VLRCROE Flight simulator and performed the first Pilot-in-the-Loop PILCFD tests at Penn State using the COCOA5 clusters. The initial tests...integration of the flight simulator and Penn State computing infrastructure. Initial tests showed slower performance than real-time (3x slower than real
Whitehead, Amy; Pottrill, Edward; Julious, Steven A; Walters, Stephen J
2018-01-01
Background/aims: External pilot trials are recommended for testing the feasibility of main or confirmatory trials. However, there is little evidence that progress in external pilot trials actually predicts randomisation and attrition rates in the main trial. To assess the use of external pilot trials in trial design, we compared randomisation and attrition rates in publicly funded randomised controlled trials with rates in their pilots. Methods: Randomised controlled trials for which there was an external pilot trial were identified from reports published between 2004 and 2013 in the Health Technology Assessment Journal. Data were extracted from published papers, protocols and reports. Bland–Altman plots and descriptive statistics were used to investigate the agreement of randomisation and attrition rates between the full and external pilot trials. Results: Of 561 reports, 41 were randomised controlled trials with pilot trials and 16 met criteria for a pilot trial with sufficient data. Mean attrition and randomisation rates were 21.1% and 50.4%, respectively, in the pilot trials and 16.8% and 65.2% in the main. There was minimal bias in the pilot trial when predicting the main trial attrition and randomisation rate. However, the variation was large: the mean difference in the attrition rate between the pilot and main trial was −4.4% with limits of agreement of −37.1% to 28.2%. Limits of agreement for randomisation rates were −47.8% to 77.5%. Conclusion: Results from external pilot trials to estimate randomisation and attrition rates should be used with caution as comparison of the difference in the rates between pilots and their associated full trial demonstrates high variability. We suggest using internal pilot trials wherever appropriate. PMID:29361833
Objective methods for developing indices of pilot workload.
DOT National Transportation Integrated Search
1977-07-01
This paper discusses the various types of objective methodologies that either have been or have the potential of being applied to the general problem of the measurement of pilot workload as it occurs on relatively short missions or mission phases. Se...
Alternatives to Piloting Textbooks.
ERIC Educational Resources Information Center
Muther, Connie
1985-01-01
Using short-term pilot programs to evaluate textbooks can lead to unreliable results and interfere with effective education. Alternative methods for evaluating textbook-based programs include obtaining documented analyses of competitors' products from sales agents, visiting districts using programs being considered, and examining publishers' own…
Wells, David B; Bhattacharya, Swati; Carr, Rogan; Maffeo, Christopher; Ho, Anthony; Comer, Jeffrey; Aksimentiev, Aleksei
2012-01-01
Molecular dynamics (MD) simulations have become a standard method for the rational design and interpretation of experimental studies of DNA translocation through nanopores. The MD method, however, offers a multitude of algorithms, parameters, and other protocol choices that can affect the accuracy of the resulting data as well as computational efficiency. In this chapter, we examine the most popular choices offered by the MD method, seeking an optimal set of parameters that enable the most computationally efficient and accurate simulations of DNA and ion transport through biological nanopores. In particular, we examine the influence of short-range cutoff, integration timestep and force field parameters on the temperature and concentration dependence of bulk ion conductivity, ion pairing, ion solvation energy, DNA structure, DNA-ion interactions, and the ionic current through a nanopore.
Ion exchange materials, method of forming ion exchange materials, and methods of treating liquids
Wertsching, Alan K.; Peterson, Eric S.; Wey, John E.
2007-12-25
The invention includes an ion affinity material having an organic component which is sulfonated and which is chemically bonded to an inorganic substrate component. The invention includes a method of forming a metal binding material. A solid support material comprising surface oxide groups is provided and an organic component having at least one alkyl halide is covalently linked to at least some of the surface oxide groups to form a modified support material. The at least one alkyl halide is subsequently converted into an alkyl sulfonate. The invention further includes a method and system for extracting ions from a liquid. An ion exchange material having a sulfonated alkyl silane component covalently bonded to a metal oxide support material is provided and a liquid is exposed to the ion exchange material.
Connick, R.E.; McVey, Wm.H.
1958-07-15
A process is described for separating plutonyl ions from the acetate ions with which they are associated in certaln carrier precipitation methods of concentrating plutonium. The method consists in adding alkaline earth metal ions and subsequently alkalizing the solution, causing formation of an alkaltne earth plutonate precipitate. Barium hydroxide is used in a preferred embodiment since it provides alkaline earth metal ion and alkalizes the solution in one step forming insoluble barium platonate.
The Military Family: A Selective Bibliography.
1981-09-01
1975 K8 iittle. Roger W ., ed. Handbook of Military Instituit ions. Beve rly 1iII s , CA: Sage, 1971. 607 1. UA 10 .1123 l.ittle, Roger W., ed. A...Program Management ." Commanh r.; Digest 18: entire issue, September 11, 1975 "CHAMPUS Complexitis Explained by ROA Sui-gt.n." CO),. Ialrrv G. Becker...lluaiv 1973 ’Missing Pilots’ Chi ldren Rece iv,, VA Schl Aid." Air Iorce ’lit:; l’ 1I, 1971 ’Mission: Financial Planning." (apt. Lvle R. Me tzlor and 2d
A Green's function method for high charge and energy ion transport.
Chun, S Y; Khandelwal, G S; Wilson, J W
1996-02-01
A heavy-ion transport code using Green's function methods is developed. The low-order perturbation terms exhibiting the greatest energy variation are used as dominant energy-dependent terms, and the higher order collision terms are evaluated using nonperturbative methods. The recently revised NUCFRG database is used to evaluate the solution for comparison with experimental data for 625A MeV 20Ne and 517A MeV 40Ar ion beams. Improved agreements with the attenuation characteristics for neon ions are found, and reasonable agreement is obtained for the transport of argon ions in water.
Colorimetric Detection of Mercury(II) Ion in Aqueous Solution Using Silver Nanoparticles.
Firdaus, M Lutfi; Fitriani, Ikka; Wyantuti, Santhy; Hartati, Yeni W; Khaydarov, Renat; McAlister, Jason A; Obata, Hajime; Gamo, Toshitaka
2017-01-01
Novel green-chemistry synthesis of silver nanoparticles (AgNPs) is introduced as a low-cost, rapid and easy-to-use analytical method for mercury ion detection. Aqueous fruit extract of water apple (Syzygium aqueum) was used for the first time as bioreductant to synthesize stable AgNPs. The prepared AgNPs have a yellowish-brown color with a surface plasmon resonance peak at 420 nm. The addition of Hg(II) ions then changes the AgNPs color to colorless. The color change was in proportion to the concentration of Hg(II) ions. The presence of other metal ions in the system was also evaluated. The proposed method shows good selectivity and sensitivity towards Hg(II) ions. Using UV-visible spectrophotometry, the detection limit of the developed method was 8.5 × 10 -7 M. The proposed method has been successfully applied for determination of Hg(II) ions in tap and lake water samples with precision better than 5%.
Current status and challenges for automotive battery production technologies
NASA Astrophysics Data System (ADS)
Kwade, Arno; Haselrieder, Wolfgang; Leithoff, Ruben; Modlinger, Armin; Dietrich, Franz; Droeder, Klaus
2018-04-01
Production technology for automotive lithium-ion battery (LIB) cells and packs has improved considerably in the past five years. However, the transfer of developments in materials, cell design and processes from lab scale to production scale remains a challenge due to the large number of consecutive process steps and the significant impact of material properties, electrode compositions and cell designs on processes. This requires an in-depth understanding of the individual production processes and their interactions, and pilot-scale investigations into process parameter selection and prototype cell production. Furthermore, emerging process concepts must be developed at lab and pilot scale that reduce production costs and improve cell performance. Here, we present an introductory summary of the state-of-the-art production technologies for automotive LIBs. We then discuss the key relationships between process, quality and performance, as well as explore the impact of materials and processes on scale and cost. Finally, future developments and innovations that aim to overcome the main challenges are presented.
Vladimirov, Gleb; Kostyukevich, Yury; Kharybin, Oleg; Nikolaev, Eugene
2017-08-01
Particle-in-cell-based realistic simulation of Fourier transform ion cyclotron resonance experiments could be used to generate ion trajectories and a signal induced on the detection electrodes. It has been shown recently that there is a modulation of "reduced" cyclotron frequencies in ion cyclotron resonance signal caused by Coulomb interaction of ion clouds. In this work it was proposed to use this modulation in order to determine frequency difference between an ion of known m/z and all other ions generating signal in ion cyclotron resonance cell. It is shown that with an increase of number of ions in ion cyclotron resonance trap, the modulation index increases, which lead to a decrease in the accuracy of determination of peak intensities by super Fourier transform resolution methods such as filter diagonalization method.
Pilot Age and Error in Air-Taxi Crashes
Rebok, George W.; Qiang, Yandong; Baker, Susan P.; Li, Guohua
2010-01-01
Introduction The associations of pilot error with the type of flight operations and basic weather conditions are well documented. The correlation between pilot characteristics and error is less clear. This study aims to examine whether pilot age is associated with the prevalence and patterns of pilot error in air-taxi crashes. Methods Investigation reports from the National Transportation Safety Board for crashes involving non-scheduled Part 135 operations (i.e., air taxis) in the United States between 1983 and 2002 were reviewed to identify pilot error and other contributing factors. Crash circumstances and the presence and type of pilot error were analyzed in relation to pilot age using Chi-square tests. Results Of the 1751 air-taxi crashes studied, 28% resulted from mechanical failure, 25% from loss of control at landing or takeoff, 7% from visual flight rule conditions into instrument meteorological conditions, 7% from fuel starvation, 5% from taxiing, and 28% from other causes. Crashes among older pilots were more likely to occur during the daytime rather than at night and off airport than on airport. The patterns of pilot error in air-taxi crashes were similar across age groups. Of the errors identified, 27% were flawed decisions, 26% were inattentiveness, 23% mishandled aircraft kinetics, 15% mishandled wind and/or runway conditions, and 11% were others. Conclusions Pilot age is associated with crash circumstances but not with the prevalence and patterns of pilot error in air-taxi crashes. Lack of age-related differences in pilot error may be attributable to the “safe worker effect.” PMID:19601508
Communications skills for CRM training
NASA Technical Reports Server (NTRS)
Shearer, M.
1984-01-01
A pilot training program in communication skills, listening, conflict solving, and task orientation, for a small but growing commuter airline is discussed. The interactions between pilots and management, and communication among crew members are examined. Methods for improvement of cockpit behavior management personnel relations are investigated.
Travel behavior of blind individuals before and after receiving orientation and mobility training.
DOT National Transportation Integrated Search
2016-09-08
In this pilot study, we devised, tested, and refined a protocol for evaluating the travel behavior of blind individuals. Preliminary analyses of our pilot study data suggest that our new method involving Global Positioning Systems (GPS), acceleromete...
Ion mobility spectrometer using frequency-domain separation
Martin, S.J.; Butler, M.A.; Frye, G.C.; Schubert, W.K.
1998-08-04
An apparatus and method are provided for separating and analyzing chemical species in an ion mobility spectrometer using a frequency-domain technique wherein the ions generated from the chemical species are selectively transported through an ion flow channel having a moving electrical potential therein. The moving electrical potential allows the ions to be selected according to ion mobility, with certain of the ions being transported to an ion detector and other of the ions being effectively discriminated against. The apparatus and method have applications for sensitive chemical detection and analysis for monitoring of exhaust gases, hazardous waste sites, industrial processes, aerospace systems, non-proliferation, and treaty verification. The apparatus can be formed as a microelectromechanical device (i.e. a micromachine). 6 figs.
Grajewski, Barbara; Waters, Martha A; Yong, Lee C; Tseng, Chih-Yu; Zivkovich, Zachary; Cassinelli, Rick T
2011-06-01
US commercial airline pilots, like all flight crew, are at increased risk for specific cancers, but the relation of these outcomes to specific air cabin exposures is unclear. Flight time or block (airborne plus taxi) time often substitutes for assessment of exposure to cosmic radiation. Our objectives were to develop methods to estimate exposures to cosmic radiation and circadian disruption for a study of chromosome aberrations in pilots and to describe workplace exposures for these pilots. Exposures were estimated for cosmic ionizing radiation and circadian disruption between August 1963 and March 2003 for 83 male pilots from a major US airline. Estimates were based on 523 387 individual flight segments in company records and pilot logbooks as well as summary records of hours flown from other sources. Exposure was estimated by calculation or imputation for all but 0.02% of the individual flight segments' block time. Exposures were estimated from questionnaire data for a comparison group of 51 male university faculty. Pilots flew a median of 7126 flight segments and 14 959 block hours for 27.8 years. In the final study year, a hypothetical pilot incurred an estimated median effective dose of 1.92 mSv (absorbed dose, 0.85 mGy) from cosmic radiation and crossed 362 time zones. This study pilot was possibly exposed to a moderate or large solar particle event a median of 6 times or once every 3.7 years of work. Work at the study airline and military flying were the two highest sources of pilot exposure for all metrics. An index of work during the standard sleep interval (SSI travel) also suggested potential chronic sleep disturbance in some pilots. For study airline flights, median segment radiation doses, time zones crossed, and SSI travel increased markedly from the 1990s to 2003 (P(trend) < 0.0001). Dose metrics were moderately correlated with records-based duration metrics (Spearman's r = 0.61-0.69). The methods developed provided an exposure profile of this group of US airline pilots, many of whom have been exposed to increasing cosmic radiation and circadian disruption from the 1990s through 2003. This assessment is likely to decrease exposure misclassification in health studies.
North, Carol S; Wohlford, Sarah E; Dean, Denis J; Black, Melissa; Balfour, Margaret E; Petrovich, James C; Downs, Dana L; Pollio, David E
2017-08-01
Tracking the movements of homeless populations presents methodological difficulties, but understanding their movements in space and time is needed to inform optimal placement of services. This pilot study developed, tested, and refined methods to apply global positioning systems (GPS) technology paired with individual narratives to chronicle the movements of homeless populations. Detail of methods development and difficulties encountered and addressed, and geospatial findings are provided. A pilot sample of 29 adults was recruited from a low-demand homeless shelter in the downtown area of Fort Worth, Texas. Pre- and post-deployment interviews provided participant characteristics and planned and retrospectively-reported travels. Only one of the first eight deployments returned with sufficient usable data. Ultimately 19 participants returned the GPS device with >20 h of usable data. Protocol adjustments addressing methodological difficulties achieved 81 % of subsequent participants returning with sufficient usable data. This study established methods and demonstrated feasibility for tracking homeless population travels.
Fault tolerant attitude sensing and force feedback control for unmanned aerial vehicles
NASA Astrophysics Data System (ADS)
Jagadish, Chirag
Two aspects of an unmanned aerial vehicle are studied in this work. One is fault tolerant attitude determination and the other is to provide force feedback to the joy-stick of the UAV so as to prevent faulty inputs from the pilot. Determination of attitude plays an important role in control of aerial vehicles. One way of defining the attitude is through Euler angles. These angles can be determined based on the measurements of the projections of the gravity and earth magnetic fields on the three body axes of the vehicle. Attitude determination in unmanned aerial vehicles poses additional challenges due to limitations of space, payload, power and cost. Therefore it provides for almost no room for any bulky sensors or extra sensor hardware for backup and as such leaves no room for sensor fault issues either. In the face of these limitations, this study proposes a fault tolerant computing of Euler angles by utilizing multiple different computation methods, with each method utilizing a different subset of the available sensor measurement data. Twenty-five such methods have been presented in this document. The capability of computing the Euler angles in multiple ways provides a diversified redundancy required for fault tolerance. The proposed approach can identify certain sets of sensor failures and even separate the reference fields from the disturbances. A bank-to-turn maneuver of the NASA GTM UAV is used to demonstrate the fault tolerance provided by the proposed method as well as to demonstrate the method of determining the correct Euler angles despite interferences by inertial acceleration disturbances. Attitude computation is essential for stability. But as of today most UAVs are commanded remotely by human pilots. While basic stability control is entrusted to machine or the on-board automatic controller, overall guidance is usually with humans. It is therefore the pilot who sets the command/references through a joy-stick. While this is a good compromise between complete automation and complete human control, it still poses some unique challenges. Pilots of manned aircraft are present inside the cockpit of the aircraft they fly and thus have a better feel of the flying environment and also the limitations of the flight. The same might not be true for UAV pilots stationed on the ground. A major handicap is that visual feedback is the only one available for the UAV pilot. An additional parameter like force feedback on the remote control joy-stick can help the UAV pilot to physically feel the limitation of the safe flight envelope. This can make the flying itself easier and safer. A method proposed here is to design a joy-stick assembly with an additional actuator. This actuator is controlled so as to generate a force feedback on the joy-stick. The control developed for this system is such that the actuator allows free movement for the pilot as long as the UAV is within the safe flight envelope. On the other hand, if it is outside this safe range, the actuator opposes the pilot's applied torque and prevents him/her from giving erroneous commands to the UAV.
Pilot training: What can surgeons learn from it?
Sommer, Kai-Jörg
2014-03-01
To provide healthcare professionals with an insight into training in aviation and its possible transfer into surgery. From research online and into company archives, relevant publications and information were identified. Current airline pilot training consists of two categories, basic training and type-rating. Training methods comprise classroom instruction, computer-based training and practical training, in either the aircraft or a flight-training device, which ranges from a fixed-base flight-training device to a full flight simulator. Pilot training not only includes technical and procedural instruction, but also training in non-technical skills like crisis management, decision-making, leadership and communication. Training syllabuses, training devices and instructors are internationally standardized and these standards are legally binding. Re-qualification and recurrent training are mandatory at all stages of a pilot's and instructor's career. Surgeons and pilots have much in common, i.e., they work in a 'real-time' three-dimensional environment under high physiological and psychological stress, operating expensive equipment, and the ultimate cost for error is measured in human lives. However, their training differs considerably. Transferring these well-tried aviation methods into healthcare will make surgical training more efficient, more effective and ultimately safer.
Parker, Suzanne L; Lipman, Jeffrey; Dimopoulos, George; Roberts, Jason A; Wallis, Steven C
2015-11-10
Quantification of fosfomycin in the plasma samples of patients is the basis of clinical pharmacokinetic studies from which evidence based dosing regimens can be devised to maximise antibiotic effectiveness against a pathogen. We have developed and validated a LC-MS/MS method to quantify fosfomycin using dried plasma spot sampling. Following HILIC chromatography, fosfomycin and ethylphosphonic acid, used as internal standard, were measured using negative-ion multiple reaction monitoring. The method was linear over the calibration range of 5-2000mg/L of fosfomycin. Intra-day assay results for dried plasma spot quality control samples at 15.6, 79.9 and 1581mg/L of fosfomycin had precision of ±4.2, 8.2, and 2.0%, respectively, and accuracy of +3.9, -0.1, and -1.2%, respectively. Recovery of fosfomycin from dried plasma spots was calculated as 83.6% and the dried plasma spot samples were found to be stable stored at room temperature for three months and when stored for four hours at 50°C. A Bland-Altman plot comparing DPS to plasma sampling found a negative bias of 16.6%, with all but one sample within the mean limits of agreement (-2.6 to 30.6%). Dried plasma spot sampling provides a useful tool for pharmacokinetic research of fosfomycin. Copyright © 2015 Elsevier B.V. All rights reserved.
Prediction of anthropometric accommodation in aircraft cockpits
NASA Astrophysics Data System (ADS)
Zehner, Gregory Franklin
Designing aircraft cockpits to accommodate the wide range of body sizes existing in the U.S. population has always been a difficult problem for Crewstation Engineers. The approach taken in the design of military aircraft has been to restrict the range of body sizes allowed into flight training, and then to develop standards and specifications to ensure that the majority of the pilots are accommodated. Accommodation in this instance is defined as the ability to: (1) Adequately see, reach, and actuate controls; (2) Have external visual fields so that the pilot can see to land, clear for other aircraft, and perform a wide variety of missions (ground support/attack or air to air combat); and (3) Finally, if problems arise, the pilot has to be able to escape safely. Each of these areas is directly affected by the body size of the pilot. Unfortunately, accommodation problems persist and may get worse. Currently the USAF is considering relaxing body size entrance requirements so that smaller and larger people could become pilots. This will make existing accommodation problems much worse. This dissertation describes a methodology for correcting this problem and demonstrates the method by predicting pilot fit and performance in the USAF T-38A aircraft based on anthropometric data. The methods described can be applied to a variety of design applications where fitting the human operator into a system is a major concern. A systematic approach is described which includes: defining the user population, setting functional requirements that operators must be able to perform, testing the ability of the user population to perform the functional requirements, and developing predictive equations for selecting future users of the system. Also described is a process for the development of new anthropometric design criteria and cockpit design methods that assure body size accommodation is improved in the future.
NASA Technical Reports Server (NTRS)
Spirkovska, Liljana (Inventor)
2006-01-01
Method and system for automatically displaying, visually and/or audibly and/or by an audible alarm signal, relevant weather data for an identified aircraft pilot, when each of a selected subset of measured or estimated aviation situation parameters, corresponding to a given aviation situation, has a value lying in a selected range. Each range for a particular pilot may be a default range, may be entered by the pilot and/or may be automatically determined from experience and may be subsequently edited by the pilot to change a range and to add or delete parameters describing a situation for which a display should be provided. The pilot can also verbally activate an audible display or visual display of selected information by verbal entry of a first command or a second command, respectively, that specifies the information required.
Audio-Visual Situational Awareness for General Aviation Pilots
NASA Technical Reports Server (NTRS)
Spirkovska, Lilly; Lodha, Suresh K.; Clancy, Daniel (Technical Monitor)
2001-01-01
Weather is one of the major causes of general aviation accidents. Researchers are addressing this problem from various perspectives including improving meteorological forecasting techniques, collecting additional weather data automatically via on-board sensors and "flight" modems, and improving weather data dissemination and presentation. We approach the problem from the improved presentation perspective and propose weather visualization and interaction methods tailored for general aviation pilots. Our system, Aviation Weather Data Visualization Environment (AWE), utilizes information visualization techniques, a direct manipulation graphical interface, and a speech-based interface to improve a pilot's situational awareness of relevant weather data. The system design is based on a user study and feedback from pilots.
The Propulsive-Only Flight Control Problem
NASA Technical Reports Server (NTRS)
Blezad, Daniel J.
1996-01-01
Attitude control of aircraft using only the throttles is investigated. The long time constants of both the engines and of the aircraft dynamics, together with the coupling between longitudinal and lateral aircraft modes make piloted flight with failed control surfaces hazardous, especially when attempting to land. This research documents the results of in-flight operation using simulated failed flight controls and ground simulations of piloted propulsive-only control to touchdown. Augmentation control laws to assist the pilot are described using both optimal control and classical feedback methods. Piloted simulation using augmentation shows that simple and effective augmented control can be achieved in a wide variety of failed configurations.
Investigation of Zero Knowledge Proof Approaches Based on Graph Theory
2011-02-01
that appears frequently in the literature is a metaheuristic algorithm called the Pilot Method. The Pilot Method improves upon another heuristic...Annual ACM-SIAM Symposium on Discrete Algorithms . Miami: ACM, 2006. 1-10. Voß, S., and C. Duin. "Look Ahead Features in Metaheuristics ." MIC2003...The Fifth Metaheuristics International Conference, 2003: 79-1 - 79-7. Woeginger, G.J. "Exact Algorithms for NP-Hard Problems: A Survey." Lecture
A comprehensive prediction and evaluation method of pilot workload
Feng, Chuanyan; Wanyan, Xiaoru; Yang, Kun; Zhuang, Damin; Wu, Xu
2018-01-01
BACKGROUND: The prediction and evaluation of pilot workload is a key problem in human factor airworthiness of cockpit. OBJECTIVE: A pilot traffic pattern task was designed in a flight simulation environment in order to carry out the pilot workload prediction and improve the evaluation method. METHODS: The prediction of typical flight subtasks and dynamic workloads (cruise, approach, and landing) were built up based on multiple resource theory, and a favorable validity was achieved by the correlation analysis verification between sensitive physiological data and the predicted value. RESULTS: Statistical analysis indicated that eye movement indices (fixation frequency, mean fixation time, saccade frequency, mean saccade time, and mean pupil diameter), Electrocardiogram indices (mean normal-to-normal interval and the ratio between low frequency and sum of low frequency and high frequency), and Electrodermal Activity indices (mean tonic and mean phasic) were all sensitive to typical workloads of subjects. CONCLUSION: A multinominal logistic regression model based on combination of physiological indices (fixation frequency, mean normal-to-normal interval, the ratio between low frequency and sum of low frequency and high frequency, and mean tonic) was constructed, and the discriminate accuracy was comparatively ideal with a rate of 84.85%. PMID:29710742
Internal pilots for a class of linear mixed models with Gaussian and compound symmetric data
Gurka, Matthew J.; Coffey, Christopher S.; Muller, Keith E.
2015-01-01
SUMMARY An internal pilot design uses interim sample size analysis, without interim data analysis, to adjust the final number of observations. The approach helps to choose a sample size sufficiently large (to achieve the statistical power desired), but not too large (which would waste money and time). We report on recent research in cerebral vascular tortuosity (curvature in three dimensions) which would benefit greatly from internal pilots due to uncertainty in the parameters of the covariance matrix used for study planning. Unfortunately, observations correlated across the four regions of the brain and small sample sizes preclude using existing methods. However, as in a wide range of medical imaging studies, tortuosity data have no missing or mistimed data, a factorial within-subject design, the same between-subject design for all responses, and a Gaussian distribution with compound symmetry. For such restricted models, we extend exact, small sample univariate methods for internal pilots to linear mixed models with any between-subject design (not just two groups). Planning a new tortuosity study illustrates how the new methods help to avoid sample sizes that are too small or too large while still controlling the type I error rate. PMID:17318914
NASA Astrophysics Data System (ADS)
Korol, Renee M.; Togonu-Bickersteth, Babajide; Yang, Victor X.; Dimov, Stamen; Vatsya, Pracha; Gordon, Maggie; Vitkin, Alex; Liu, Liying; Canham, Peter; Clarke, Sharon; Lucas, Alexandra
2003-10-01
Atherosclerosis is the underlying vascular pathology that initiates arterial thromboembolic occlusions (myocardial infarctions, strokes and peripheral vessel blockage). Two imaging modalities, Optical Coherence Tomography (OCT) and Time-of-Flight Secondary Ion Mass Spectrometry (ToF-SIMS), were investigated for detection and compositional analysis of unstable plaque associated with plaque erosion and sudden occlusion. OCT produces high resolution images whereas mass spectrometry images provide information on the spatial distribution of chemical elements. Diseased carotid arteries taken from patients with high-risk lesions were imaged with OCT and ToF-SIMS to give molecular and metabolic information, and matched with histopathology. OCT results show clear indications of vascular remodeling by the presence of fatty acid deposits, fibrous tissue and calcifications. ToF-SIMS further characterized changes based on secondary ion topography analysis where a high 23Na/39K ratio was indicative of arterial tissue degradation and the amount of 40Ca corresponded with late stage atherosclerosis. This pilot experiment has demonstrated that in vitro OCT imaging and ToF-SIMS of diseased carotid arteries have scientific merit for targeting clinically relevant morphology and metabolic changes to compare stable and unstable plaque. These optical techniques provide complimentary metabolic and molecular information on unstable plaque, specifically cell break-down with altered ion ratios of 23Na, 39K and 40Ca.
2004-12-01
Jones interaction potential is included45 better results are obtained but this method at times overestimates cross-sections in the intermediate 1500 to...utilized to generate sodiated [(PMA)Cp7T8]xNa+ ions, and their collision cross-sections were measured in helium using ion mobility based methods...were measured in helium using ion mobility based methods. Results for x = 1, 2, and 3 were consistent with only one conformer occurring for the Na+1
Flow injection trace gas analysis method for on-site determination of organoarsenicals
Aldstadt, III, Joseph H.
1997-01-01
A method for real-time determination of the concentration of Lewisite in the ambient atmosphere, the method includes separating and collecting a Lewisite sample from the atmosphere in a collection chamber, converting the collected Lewisite to an arsenite ion solution sample, pumping the arsenite ion containing sample to an electrochemical detector connected to the collection chamber, and electrochemically detecting the converted arsenite ions in the sample, whereby the concentration of arsenite ions detected is proportional to the concentration of Lewisite in the atmosphere.
Dealing With Unexpected Events on the Flight Deck: A Conceptual Model of Startle and Surprise
Landman, Annemarie; Groen, Eric L.; van Paassen, M. M. (René); Bronkhorst, Adelbert W.; Mulder, Max
2017-01-01
Objective: A conceptual model is proposed in order to explain pilot performance in surprising and startling situations. Background: Today’s debate around loss of control following in-flight events and the implementation of upset prevention and recovery training has highlighted the importance of pilots’ ability to deal with unexpected events. Unexpected events, such as technical malfunctions or automation surprises, potentially induce a “startle factor” that may significantly impair performance. Method: Literature on surprise, startle, resilience, and decision making is reviewed, and findings are combined into a conceptual model. A number of recent flight incident and accident cases are then used to illustrate elements of the model. Results: Pilot perception and actions are conceptualized as being guided by “frames,” or mental knowledge structures that were previously learned. Performance issues in unexpected situations can often be traced back to insufficient adaptation of one’s frame to the situation. It is argued that such sensemaking or reframing processes are especially vulnerable to issues caused by startle or acute stress. Conclusion: Interventions should focus on (a) increasing the supply and quality of pilot frames (e.g., though practicing a variety of situations), (b) increasing pilot reframing skills (e.g., through the use of unpredictability in training scenarios), and (c) improving pilot metacognitive skills, so that inappropriate automatic responses to startle and surprise can be avoided. Application: The model can be used to explain pilot behavior in accident cases, to design experiments and training simulations, to teach pilots metacognitive skills, and to identify intervention methods. PMID:28777917
Flight deck crew coordination indices of workload and situation awareness in terminal operations
NASA Astrophysics Data System (ADS)
Ellis, Kyle Kent Edward
Crew coordination in the context of aviation is a specifically choreographed set of tasks performed by each pilot, defined for each phase of flight. Based on the constructs of effective Crew Resource Management and SOPs for each phase of flight, a shared understanding of crew workload and task responsibility is considered representative of well-coordinated crews. Nominal behavior is therefore defined by SOPs and CRM theory, detectable through pilot eye-scan. This research investigates the relationship between the eye-scan exhibited by each pilot and the level of coordination between crewmembers. Crew coordination was evaluated based on each pilot's understanding of the other crewmember's workload. By contrasting each pilot's workload-understanding, crew coordination was measured as the summed absolute difference of each pilot's understanding of the other crewmember's reported workload, resulting in a crew coordination index. The crew coordination index rates crew coordination on a scale ranging across Excellent, Good, Fair and Poor. Eye-scan behavior metrics were found to reliably identify a reduction in crew coordination. Additionally, crew coordination was successfully characterized by eye-scan behavior data using machine learning classification methods. Identifying eye-scan behaviors on the flight deck indicative of reduced crew coordination can be used to inform training programs and design enhanced avionics that improve the overall coordination between the crewmembers and the flight deck interface. Additionally, characterization of crew coordination can be used to develop methods to increase shared situation awareness and crew coordination to reduce operational and flight technical errors. Ultimately, the ability to reduce operational and flight technical errors made by pilot crews improves the safety of aviation.
Pilot-in-the-Loop CFD Method Development
2017-02-01
Penn State University. All software supporting piloted simulations must run at real time speeds or faster. This requirement drives the number of...dynamics of interacting blade tip vortices with a ground plane,” American Helicopter Society 64 th Annual Forum Proceedings, 2008. [2] Johnson, W
Underground mineral extraction
NASA Technical Reports Server (NTRS)
Miller, C. G.; Stephens, J. B.
1980-01-01
A method was developed for extracting underground minerals such as coal, which avoids the need for sending personnel underground and which enables the mining of steeply pitched seams of the mineral. The method includes the use of a narrow vehicle which moves underground along the mineral seam and which is connected by pipes or hoses to water pumps at the surface of the Earth. The vehicle hydraulically drills pilot holes during its entrances into the seam, and then directs sideward jets at the seam during its withdrawal from each pilot hole to comminute the mineral surrounding the pilot hole and combine it with water into a slurry, so that the slurried mineral can flow to a location where a pump raises the slurry to the surface.
Power conditioning system modelling for nuclear electric propulsion
NASA Astrophysics Data System (ADS)
Metcalf, Kenneth J.
1993-11-01
NASA LeRC is currently developing a Fortran based model of a complete nuclear electric propulsion (NEP) vehicle that would be used for piloted and cargo missions to the Moon or Mars. The proposed vehicle design will use either a Brayton or K-Rankine power conversion cycle to drive a turbine coupled with a rotary alternator. Two thruster types are also being studied, ion and magnetoplasmadynamic (MPD). In support of this NEP model, Rocketdyne developed a power management and distribution (PMAD) subroutine that provides parametric outputs for selected alternator operating voltages and frequencies, thruster types, system power levels, and electronics coldplate temperatures. The end-to-end PMAD model described is based on the direct use of the alternator voltage and frequency for transmitting power to either ion or MPD thrusters. This low frequency transmission approach was compared with dc and high frequency ac designs, and determined to have the lowest mass, highest efficiency, highest reliability and lowest development costs. While its power quality is not as good as that provided by a high frequency system, it was considered adequate for both ion and MPD engine applications. The low frequency architecture will be used as the reference in future NEP PMAD studies.
Power Conditioning System Modelling for Nuclear Electric Propulsion
NASA Technical Reports Server (NTRS)
Metcalf, Kenneth J.
1993-01-01
NASA LeRC is currently developing a Fortran based model of a complete nuclear electric propulsion (NEP) vehicle that would be used for piloted and cargo missions to the Moon or Mars. The proposed vehicle design will use either a Brayton or K-Rankine power conversion cycle to drive a turbine coupled with a rotary alternator. Two thruster types are also being studied, ion and magnetoplasmadynamic (MPD). In support of this NEP model, Rocketdyne developed a power management and distribution (PMAD) subroutine that provides parametric outputs for selected alternator operating voltages and frequencies, thruster types, system power levels, and electronics coldplate temperatures. The end-to-end PMAD model described is based on the direct use of the alternator voltage and frequency for transmitting power to either ion or MPD thrusters. This low frequency transmission approach was compared with dc and high frequency ac designs, and determined to have the lowest mass, highest efficiency, highest reliability and lowest development costs. While its power quality is not as good as that provided by a high frequency system, it was considered adequate for both ion and MPD engine applications. The low frequency architecture will be used as the reference in future NEP PMAD studies.
The pilot plant for electron beam food processing
NASA Astrophysics Data System (ADS)
Migdal, W.; Walis, L.; Chmielewski, A. G.
1993-07-01
In the frames of the national programme on the application of irradiation for food preservation and hygienization an experimental plant for electron beam processing has been established in INCT. The pilot plant has been constructed inside an old fort what decreases significantly the cost of the investment. The pilot plant is equipped with a small research accelerator Pilot (10 MeV, 1 kW) and an industrial unit Elektronika (10 MeV, 10 kW). This allows both laboratory and full technological scale testing of the elaborated process to be conducted. The industrial unit is being equipped with e-/X conversion target, for high density products irradiation. On the basis of the research there were performed at different scientific institutions in Poland, health authorities have issued permissions for permanent treatment of spices, garlic, onions and temporary permissions for mushrooms, and potatoes. Dosimetric methods have been elaborated for the routine use at the plant. In the INCT laboratory methods for the control of e-/X treated food have been established.
Van Atta, C.M.; Beringer, R.; Smith, L.
1959-01-01
A linear accelerator of heavy ions is described. The basic contributions of the invention consist of a method and apparatus for obtaining high energy particles of an element with an increased charge-to-mass ratio. The method comprises the steps of ionizing the atoms of an element, accelerating the resultant ions to an energy substantially equal to one Mev per nucleon, stripping orbital electrons from the accelerated ions by passing the ions through a curtain of elemental vapor disposed transversely of the path of the ions to provide a second charge-to-mass ratio, and finally accelerating the resultant stripped ions to a final energy of at least ten Mev per nucleon.
Park, Ji-Won; Jeong, Hyobin; Kang, Byeongsoo; Kim, Su Jin; Park, Sang Yoon; Kang, Sokbom; Kim, Hark Kyun; Choi, Joon Sig; Hwang, Daehee; Lee, Tae Geol
2015-06-05
Time-of-flight secondary ion mass spectrometry (TOF-SIMS) emerges as a promising tool to identify the ions (small molecules) indicative of disease states from the surface of patient tissues. In TOF-SIMS analysis, an enhanced ionization of surface molecules is critical to increase the number of detected ions. Several methods have been developed to enhance ionization capability. However, how these methods improve identification of disease-related ions has not been systematically explored. Here, we present a multi-dimensional SIMS (MD-SIMS) that combines conventional TOF-SIMS and metal-assisted SIMS (MetA-SIMS). Using this approach, we analyzed cancer and adjacent normal tissues first by TOF-SIMS and subsequently by MetA-SIMS. In total, TOF- and MetA-SIMS detected 632 and 959 ions, respectively. Among them, 426 were commonly detected by both methods, while 206 and 533 were detected uniquely by TOF- and MetA-SIMS, respectively. Of the 426 commonly detected ions, 250 increased in their intensities by MetA-SIMS, whereas 176 decreased. The integrated analysis of the ions detected by the two methods resulted in an increased number of discriminatory ions leading to an enhanced separation between cancer and normal tissues. Therefore, the results show that MD-SIMS can be a useful approach to provide a comprehensive list of discriminatory ions indicative of disease states.
Park, Ji-Won; Jeong, Hyobin; Kang, Byeongsoo; Kim, Su Jin; Park, Sang Yoon; Kang, Sokbom; Kim, Hark Kyun; Choi, Joon Sig; Hwang, Daehee; Lee, Tae Geol
2015-01-01
Time-of-flight secondary ion mass spectrometry (TOF-SIMS) emerges as a promising tool to identify the ions (small molecules) indicative of disease states from the surface of patient tissues. In TOF-SIMS analysis, an enhanced ionization of surface molecules is critical to increase the number of detected ions. Several methods have been developed to enhance ionization capability. However, how these methods improve identification of disease-related ions has not been systematically explored. Here, we present a multi-dimensional SIMS (MD-SIMS) that combines conventional TOF-SIMS and metal-assisted SIMS (MetA-SIMS). Using this approach, we analyzed cancer and adjacent normal tissues first by TOF-SIMS and subsequently by MetA-SIMS. In total, TOF- and MetA-SIMS detected 632 and 959 ions, respectively. Among them, 426 were commonly detected by both methods, while 206 and 533 were detected uniquely by TOF- and MetA-SIMS, respectively. Of the 426 commonly detected ions, 250 increased in their intensities by MetA-SIMS, whereas 176 decreased. The integrated analysis of the ions detected by the two methods resulted in an increased number of discriminatory ions leading to an enhanced separation between cancer and normal tissues. Therefore, the results show that MD-SIMS can be a useful approach to provide a comprehensive list of discriminatory ions indicative of disease states. PMID:26046669
Long-term effects of exercise programs among helicopter pilots with flying related LBP
Andersen, Knut; Baardsen, Roald; Dalen, Ingvild; Larsen, Jan Petter
2017-01-01
BACKGROUND: Flying related transient Low Back Pain (LBP) among helicopter pilots is considered an occupational distress. OBJECTIVE: To examine if exercise programs can alleviate transient LBP. METHODS: Sixty-five helicopter pilots (92% males), all reporting flying related LBP, responded to an epidemiological survey and a long-term follow-up, 44.8 months later, comprising questions regarding transient LBP and number of sick leaves. Data from 37 pilots participating in two exercise programs, A; general for LBP, B; focused for lumbar trunk (LT), included information from clinical examinations and muscular endurance tests of the LT before and after intervention. Twenty-eight pilots did not participate in any intervention. RESULTS: At long-term follow-up 42% of the pilots still reported flying related transient LBP. Among participants in program B 26% had persistent pain, 70% in program A and 46% among pilots without intervention. Sick-leave reduction was only observed among participants in program B (30% to 4%). Upon re-occurrence of LBP symptoms, half of the pilots in program B again performed exercises to improve their pain. CONCLUSION: This study indicates that exercise programs focused towards lumbar trunk muscular endurance reduces flying related transient LBP and sick-leave among helicopter pilots. These findings may have implications for the pilots’ working conditions. PMID:29278872
NASA Astrophysics Data System (ADS)
Shoji, Masafumi; Miyoshi, Yoshizumi; Katoh, Yuto; Keika, Kunihiro; Angelopoulos, Vassilis; Kasahara, Satoshi; Asamura, Kazushi; Nakamura, Satoko; Omura, Yoshiharu
2017-09-01
Electromagnetic plasma waves are thought to be responsible for energy exchange between charged particles in space plasmas. Such an energy exchange process is evidenced by phase space holes identified in the ion distribution function and measurements of the dot product of the plasma wave electric field and the ion velocity. We develop a method to identify ion hole formation, taking into consideration the phase differences between the gyromotion of ions and the electromagnetic ion cyclotron (EMIC) waves. Using this method, we identify ion holes in the distribution function and the resulting nonlinear EMIC wave evolution from Time History of Events and Macroscale Interactions during Substorms (THEMIS) observations. These ion holes are key to wave growth and frequency drift by the ion currents through nonlinear wave-particle interactions, which are identified by a computer simulation in this study.
Nakabayashi, Ryo; Tsugawa, Hiroshi; Kitajima, Mariko; Takayama, Hiromitsu; Saito, Kazuki
2015-01-01
In metabolomics, the analysis of product ions in tandem mass spectrometry (MS/MS) is noteworthy to chemically assign structural information. However, the development of relevant analytical methods are less advanced. Here, we developed a method to boost sensitivity in liquid chromatography–Fourier transform ion cyclotron resonance–tandem mass spectrometry analysis (MS/MS boost analysis). To verify the MS/MS boost analysis, both quercetin and uniformly labeled 13C quercetin were analyzed, revealing that the origin of the product ions is not the instrument, but the analyzed compounds resulting in sensitive product ions. Next, we applied this method to the analysis of monoterpene indole alkaloids (MIAs). The comparative analyses of MIAs having indole basic skeleton (ajmalicine, catharanthine, hirsuteine, and hirsutine) and oxindole skeleton (formosanine, isoformosanine, pteropodine, isopteropodine, rhynchophylline, isorhynchophylline, and mitraphylline) identified 86 and 73 common monoisotopic ions, respectively. The comparative analyses of the three pairs of stereoisomers showed more than 170 common monoisotopic ions in each pair. This method was also applied to the targeted analysis of MIAs in Catharanthus roseus and Uncaria rhynchophylla to profile indole and oxindole compounds using the product ions. This analysis is suitable for chemically assigning features of the metabolite groups, which contributes to targeted metabolome analysis. PMID:26734034
White Matter Integrity in High-Altitude Pilots Exposed to Hypobaria
McGuire, Stephen A.; Boone, Goldie R.E.; Sherman, Paul M.; Tate, David F.; Wood, Joe D.; Patel, Beenish; Eskandar, George; Wijtenburg, S. Andrea; Rowland, Laura M.; Clarke, Geoffrey D.; Grogan, Patrick M.; Sladky, John H.; Kochunov, Peter V.
2017-01-01
Introduction Nonhypoxic hypobaric (low atmospheric pressure) occupational exposure, such as experienced by U.S. Air Force U-2 pilots and safety personnel operating inside altitude chambers, is associated with increased subcortical white matter hyperintensity (WMH) burden. The pathophysiological mechanisms underlying this discrete WMH change remain unknown. The objectives of this study were to demonstrate that occupational exposure to nonhypoxic hypobaria is associated with altered white matter integrity as quantified by fractional anisotropy (FA) measured using diffusion tensor imaging and relate these findings to WMH burden and neurocognitive ability. Methods There were 102 U-2 pilots and 114 age- and gender-controlled, health-matched controls who underwent magnetic resonance imaging. All pilots performed neurocognitive assessment. Whole-brain and tract-wise average FA values were compared between pilots and controls, followed by comparison within pilots separated into high and low WMH burden groups. Neurocognitive measurements were used to help interpret group difference in FA values. Results Pilots had significantly lower average FA values than controls (0.489/0.500, respectively). Regionally, pilots had higher FA values in the fronto-occipital tract where FA values positively correlated with visual-spatial performance scores (0.603/0.586, respectively). There was a trend for high burden pilots to have lower FA values than low burden pilots. Discussion Nonhypoxic hypobaric exposure is associated with significantly lower average FA in young, healthy U-2 pilots. This suggests that recurrent hypobaric exposure causes diffuse axonal injury in addition to focal white matter changes. PMID:28323582
Methods for Multiloop Identification of Visual and Neuromuscular Pilot Responses.
Olivari, Mario; Nieuwenhuizen, Frank M; Venrooij, Joost; Bülthoff, Heinrich H; Pollini, Lorenzo
2015-12-01
In this paper, identification methods are proposed to estimate the neuromuscular and visual responses of a multiloop pilot model. A conventional and widely used technique for simultaneous identification of the neuromuscular and visual systems makes use of cross-spectral density estimates. This paper shows that this technique requires a specific noninterference hypothesis, often implicitly assumed, that may be difficult to meet during actual experimental designs. A mathematical justification of the necessity of the noninterference hypothesis is given. Furthermore, two methods are proposed that do not have the same limitations. The first method is based on autoregressive models with exogenous inputs, whereas the second one combines cross-spectral estimators with interpolation in the frequency domain. The two identification methods are validated by offline simulations and contrasted to the classic method. The results reveal that the classic method fails when the noninterference hypothesis is not fulfilled; on the contrary, the two proposed techniques give reliable estimates. Finally, the three identification methods are applied to experimental data from a closed-loop control task with pilots. The two proposed techniques give comparable estimates, different from those obtained by the classic method. The differences match those found with the simulations. Thus, the two identification methods provide a good alternative to the classic method and make it possible to simultaneously estimate human's neuromuscular and visual responses in cases where the classic method fails.
Loziuk, Philip L.; Sederoff, Ronald R.; Chiang, Vincent L.; Muddiman, David C.
2014-01-01
Quantitative mass spectrometry has become central to the field of proteomics and metabolomics. Selected reaction monitoring is a widely used method for the absolute quantification of proteins and metabolites. This method renders high specificity using several product ions measured simultaneously. With growing interest in quantification of molecular species in complex biological samples, confident identification and quantitation has been of particular concern. A method to confirm purity or contamination of product ion spectra has become necessary for achieving accurate and precise quantification. Ion abundance ratio assessments were introduced to alleviate some of these issues. Ion abundance ratios are based on the consistent relative abundance (RA) of specific product ions with respect to the total abundance of all product ions. To date, no standardized method of implementing ion abundance ratios has been established. Thresholds by which product ion contamination is confirmed vary widely and are often arbitrary. This study sought to establish criteria by which the relative abundance of product ions can be evaluated in an absolute quantification experiment. These findings suggest that evaluation of the absolute ion abundance for any given transition is necessary in order to effectively implement RA thresholds. Overall, the variation of the RA value was observed to be relatively constant beyond an absolute threshold ion abundance. Finally, these RA values were observed to fluctuate significantly over a 3 year period, suggesting that these values should be assessed as close as possible to the time at which data is collected for quantification. PMID:25154770
Ion-beam apparatus and method for analyzing and controlling integrated circuits
Campbell, A.N.; Soden, J.M.
1998-12-01
An ion-beam apparatus and method for analyzing and controlling integrated circuits are disclosed. The ion-beam apparatus comprises a stage for holding one or more integrated circuits (ICs); a source means for producing a focused ion beam; and a beam-directing means for directing the focused ion beam to irradiate a predetermined portion of the IC for sufficient time to provide an ion-beam-generated electrical input signal to a predetermined element of the IC. The apparatus and method have applications to failure analysis and developmental analysis of ICs and permit an alteration, control, or programming of logic states or device parameters within the IC either separate from or in combination with applied electrical stimulus to the IC for analysis thereof. Preferred embodiments of the present invention including a secondary particle detector and an electron floodgun further permit imaging of the IC by secondary ions or electrons, and allow at least a partial removal or erasure of the ion-beam-generated electrical input signal. 4 figs.
Ion-beam apparatus and method for analyzing and controlling integrated circuits
Campbell, Ann N.; Soden, Jerry M.
1998-01-01
An ion-beam apparatus and method for analyzing and controlling integrated circuits. The ion-beam apparatus comprises a stage for holding one or more integrated circuits (ICs); a source means for producing a focused ion beam; and a beam-directing means for directing the focused ion beam to irradiate a predetermined portion of the IC for sufficient time to provide an ion-beam-generated electrical input signal to a predetermined element of the IC. The apparatus and method have applications to failure analysis and developmental analysis of ICs and permit an alteration, control, or programming of logic states or device parameters within the IC either separate from or in combination with applied electrical stimulus to the IC for analysis thereof. Preferred embodiments of the present invention including a secondary particle detector and an electron floodgun further permit imaging of the IC by secondary ions or electrons, and allow at least a partial removal or erasure of the ion-beam-generated electrical input signal.
A simple and rapid method for high-resolution visualization of single-ion tracks
DOE Office of Scientific and Technical Information (OSTI.GOV)
Omichi, Masaaki; Center for Collaborative Research, Anan National College of Technology, Anan, Tokushima 774-0017; Choi, Wookjin
2014-11-15
Prompt determination of spatial points of single-ion tracks plays a key role in high-energy particle induced-cancer therapy and gene/plant mutations. In this study, a simple method for the high-resolution visualization of single-ion tracks without etching was developed through the use of polyacrylic acid (PAA)-N, N’-methylene bisacrylamide (MBAAm) blend films. One of the steps of the proposed method includes exposure of the irradiated films to water vapor for several minutes. Water vapor was found to promote the cross-linking reaction of PAA and MBAAm to form a bulky cross-linked structure; the ion-track scars were detectable at a nanometer scale by atomic forcemore » microscopy. This study demonstrated that each scar is easily distinguishable, and the amount of generated radicals of the ion tracks can be estimated by measuring the height of the scars, even in highly dense ion tracks. This method is suitable for the visualization of the penumbra region in a single-ion track with a high spatial resolution of 50 nm, which is sufficiently small to confirm that a single ion hits a cell nucleus with a size ranging between 5 and 20 μm.« less
Ion composition and temperature in the topside ionosphere.
NASA Technical Reports Server (NTRS)
Brace, L. H.; Dunham, G. S.; Mayr, H. G.
1967-01-01
Particle and energy continuity equations derived and solved by computer method ion composition and plasma temperature measured by Explorer XXII PARTICLE and energy continuity equations derived and solved by computer method for ion composition and plasma temperature measured by Explorer XXII
Parkhurst, David L.; Christenson, Scott C.; Schlottmann, Jamie L.
1989-01-01
Beginning in 1986, the Congress annually has appropriated funds for the U.S. Geological Survey to test and refine concepts for a National Water-Quality Assessment (NAWQA) Program. The long-term goals of a full-scale program would be to:Provide a nationally consistent description of current water-quality conditions for a large part of the Nation's surface- and ground-water resources;Define long-term trends (or lack of trends) in water quality; andIdentify, describe, and explain, as possible, the major factors that affect the observed water-quality conditions and trends.The results of the NAWQA Program will be made available to water managers, policy makers, and the public, and will provide an improved scientific basis for evaluating the effectiveness of water-quality management programs.At present (1988), the assessment program is in a pilot phase in seven project areas throughout the country that represent diverse hydrologic environments and water-quality conditions. The Central Oklahoma aquifer project is one of three pilot ground-water projects. One of the initial activities performed by each pilot project was to compile, screen, and interpret the large amount of water-quality data available within each study unit.The purpose of this report is to assess the water quality of the Central Oklahoma aquifer using the information available through 1987. The scope of the work includes compiling data from Federal, State, and local agencies; evaluating the suitability of the information for conducting a regional water-quality assessment; mapping regional variations in major-ion chemistry; calculating summary statistics of the available water-quality data; producing maps to show the location and number of samples that exceeded water-quality standards; and performing contingency-table analyses to determine the relation of geologic unit and depth to the occurrence of chemical constituents that exceed water-quality standards. This report provides an initial description of water-quality conditions in the Central Oklahoma aquifer study unit. No attempt was made in this report to determine the causes for regional variations in major-ion chemistry or to examine the reasons that some chemical constituents exceed water-quality standards.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schonewill, Philip P.; Russell, Renee L.; Daniel, Richard C.
The Low Activity Waste Pretreatment System (LAWPS) is being designed to enable the direct feed of waste to the Hanford Tank Waste Treatment and Immobilization Plant (WTP) Low Activity Waste (LAW) facility to be immobilized. Prior to construction of the LAWPS, pilot-scale integrated testing of the key unit operations (crossflow filtration, ion exchange using spherical resorcinol-formaldehyde (sRF) resin) will be conducted by a team led by Washington River Protection Solutions (WRPS) to increase the technology maturation level of the facility’s critical technology elements. As a part of this effort, Pacific Northwest National Laboratory (PNNL) has conducted a series of bench-scalemore » (or engineering-scale) tests to perform two major objectives: (1) support pilot-scale integrated testing of the LAWPS by supplying information or performance data in advance of operating the pilot-scale facility; and (2) collect data needed to establish or confirm assumptions/approaches planned for implementation in the LAWPS safety basis. The first objective was focused in two technical areas: developing simulants that are representative of expected waste feed and can be produced at larger scales, and using these simulants in a bench-scale crossflow filter to establish expected solid-liquid separation performance. The crossflow filter was also used to observe the efficacy (with respect to filter production rate) of selected operational strategies. The second objective also included two technical areas: measuring the effect of sRF resin on hydrogen generation rate under irradiation, and demonstrating that the planned hydrogen management approach is effective and robust. The hydrogen management strategy involves fluidization of the sRF resin bed in the ion exchange columns and recirculating the liquid, a scenario that is planned for testing at full column height. The full height tests at PNNL also supported full-scale IX column testing conducted as part of the technology maturation plan. The experimental approaches used at PNNL in these four technical areas are summarized and selected key preliminary results are provided.« less
Brazil advances subsea technology in Marlim pilot
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1993-03-29
Petroleum Brasileiro SA has extended several water depth records for subsea technology during a pilot project in giant Marlim oil field in the Campos basin off Brazil. Petrobras finished the 10 well Marlim pilot last December. The field's pilot phase was intended to begin early production and enable Petrobras to gather more reservoir data. Ten satellite wells, including two prepilot wells, were completed during the Marlim pilot phase with guidelineless (GLL) wet christmas trees designed and fabricated by FMC Corp., Houston, and CBV Industrial Mechanic SA, Rio de Janeiro. The subsea wells are producing 52,000 b/d of oil and 21.19more » MMCfd of gas in water depths of 1,847-2,562 ft. Marlim pilot well flow is routed to a permanent semisubmersible floating production system (FPS). Oil moves from the FPS to a monobuoy that offloads to a shuttle tanker. In addition to marking the first successful uses of purpose-built GLL wet trees, FMC said the Marlim pilot project allowed GLL subsea technology to evolve from conceptual status into a proven deepwater completion method. The paper describes the project.« less
Preston, Claire; Burch, Sarah
2018-01-01
Objectives To understand and explain whether a dementia buddies pilot introduced into two adjacent mental health hospital wards in England was achieving its aim of enhancing person-centred care. Methods The research used a cultural lens to evaluate the dementia buddies pilot. It comprised 20 in-depth semi-structured interviews with staff, volunteers and carers in the two wards where the pilot was introduced. Results The pilot's ability to deliver positive outcomes depended on its compatibility with the culture of the ward and it performed better in the ward where a person-centred culture of care already existed. In this ward, the pilot became a catalyst for improved experience among patients, carers and staff, whereas in the second ward, the pilot faced resistance from staff and achieved less. Conclusions This finding underlines the benefit of focusing on workplace culture to understand the performance of volunteer-led initiatives. It also shows that existing ward culture is a determining factor in the capacity for dementia buddy schemes to act as vehicles for culture change.
Modeling human response errors in synthetic flight simulator domain
NASA Technical Reports Server (NTRS)
Ntuen, Celestine A.
1992-01-01
This paper presents a control theoretic approach to modeling human response errors (HRE) in the flight simulation domain. The human pilot is modeled as a supervisor of a highly automated system. The synthesis uses the theory of optimal control pilot modeling for integrating the pilot's observation error and the error due to the simulation model (experimental error). Methods for solving the HRE problem are suggested. Experimental verification of the models will be tested in a flight quality handling simulation.
2006-03-01
LocataLite Test Examples. LocataLites have been used in several experimental trials as pilot studies of the system. 1.7.5.1 BlueScope Steel. In this pilot...study, [2], the Locata system is shown to give centimeter level relative positioning precision in a severe multipath en- vironment. The BlueScope ...Using Locata: A pilot study at BlueScope Steel.” Proceedings of the 2004 Annual Meeting of the U.S. Institute of Navigation. Dayton, OH, June 2004. 3
Microscopic morphology evolution during ion beam smoothing of Zerodur® surfaces.
Liao, Wenlin; Dai, Yifan; Xie, Xuhui; Zhou, Lin
2014-01-13
Ion sputtering of Zerodur material often results in the formation of nanoscale microstructures on the surfaces, which seriously influences optical surface quality. In this paper, we describe the microscopic morphology evolution during ion sputtering of Zerodur surfaces through experimental researches and theoretical analysis, which shows that preferential sputtering together with curvature-dependent sputtering overcomes ion-induced smoothing mechanisms leading to granular nanopatterns formation in morphology and the coarsening of the surface. Consequently, we propose a new method for ion beam smoothing (IBS) of Zerodur optics assisted by deterministic ion beam material adding (IBA) technology. With this method, Zerodur optics with surface roughness down to 0.15 nm root mean square (RMS) level is obtained through the experimental investigation, which demonstrates the feasibility of our proposed method.
[Methodological aspects of the assessment of phytotoxicic properties of ice-melter reagents].
Sbitnev, A V; Vodianova, M A; Kriatov, I A; Donerian, L G; Evseeva, I S; Ushakova, O V; Ushakov, D I; Matveeva, I S; Rodionova, O M
One of the main criteria which determine the possibility of the use of a particular type of ice-melter reagents (IMR) is the degree of their safety for the environment and human health, which is reflected in the establishment of safe doses and concentrations. In this regard, the current area of research is to improve the ecological and epidemiological principles of risk assessment of modern types of anti-icing agents. Currently available data concerning monitoring soil studies and the snow held in various cities of Russia, show that there is a process of accumulation of the main components of IMR - sodium and chlorine ions in the areas related to the roadway. The article is designated a problem of existing methodological approaches to the assessment of the phytotoxic impact in the investigation of anti-icing agents in the laboratory. There was executed the comparative characteristics of the results of the preliminary pilot studies on the phytotoxic properties of IMR under using different substrates for germination of seeds - soil and filter paper. The data obtained are characterized by differences in the degree of phytotoxic action of the same species depending upon ice-melter reagents methodical setting circuit laboratory experiment. As a result, there was shown the imperfection of the existing method of rapid analysis in relation to ice-melter materials (IMM).
Duong, Hong Anh; Le, Minh Duc; Nguyen, Kim Diem Mai; Hauser, Peter C; Pham, Hung Viet; Mai, Thanh Duc
2015-11-01
A simple and inexpensive method for the determination of various ionic species in different water matrices is discussed in this study. The approach is based on the employment of in-house-made capillary electrophoresis (CE) instruments with capacitively coupled contactless conductivity detection (C(4)D), which can be realized even when only a modest financial budget and limited expertise are available. Advantageous features and considerations of these instruments are detailed following their pilot deployment in Vietnam. Different categories of ionic species, namely major inorganic cations (K(+), Na(+), Ca(2+), Mg(2+), and NH4(+)) and major inorganic anions (Cl(-), NO3(-), NO2(-), SO4(2-), and phosphate), in different water matrices in Vietnam were determined using these in-house fabricated instruments. Inorganic trivalent arsenic (As(iii)), which is the most abundant form of arsenic in reducing groundwater, was determined by CE-C(4)D. The effect of some interfering ions in groundwater on the analytical performance was investigated and is highlighted. The results from in-house-made CE-C(4)D-instruments were cross-checked with those obtained using the standard methods (AAS, AES, UV and IC), with correlation coefficients r(2) ≥ 0.9 and deviations from the referenced results less than 15%.
NASA Astrophysics Data System (ADS)
De Cino, Thomas J., II
In the aviation industry, digitally produced and presented flight, navigation, and aircraft information is commonly referred to as glass flight decks. Glass flight decks are driven by computer-based subsystems and have long been a part of military and commercial aviation sectors. Over the past 15 years, the General Aviation (GA) sector of the aviation industry has become a recent beneficiary of the rapid advancement of computer-based glass flight deck (GFD) systems. While providing the GA pilot considerable enhancements in the quality of information about the status and operations of the aircraft, training pilots on the use of glass flight decks is often delivered with traditional methods (e.g. textbooks, PowerPoint presentations, user manuals, and limited computer-based training modules). These training methods have been reported as less than desirable in learning to use the glass flight deck interface. Difficulties in achieving a complete understanding of functional and operational characteristics of the GFD systems, acquiring a full understanding of the interrelationships of the varied subsystems, and handling the wealth of flight information provided have been reported. Documented pilot concerns of poor user experience and satisfaction, and problems with the learning the complex and sophisticated interface of the GFD are additional issues with current pilot training approaches. A case study was executed to explore ways to improve training using GFD systems at a Midwestern aviation university. The researcher investigated if variations in instructional systems design and training methods for learning glass flight deck technology would affect the perceptions and attitudes of pilots of the learnability (an attribute of usability) of the glass flight deck interface. Specifically, this study investigated the effectiveness of scenario-based training (SBT) methods to potentially improve pilot knowledge and understanding of a GFD system, and overall pilot user experience and satisfaction. Participants overwhelmingly reported positive learning experiences from scenario-based GFD systems flight training, noting that learning and knowledge construction were improved over other training received in the past. In contrast, participants rated the usability and learnability of the GFD training systems low, reporting various problems with the systems' interface, and the learnability (first-time use) of the complex GFD system. However, issues with usability of the GFD training systems did not reduce or change participant attitudes towards learning and mastering GFD systems; to the contrary, all participants requested additional coursework opportunities to train on GFD systems with the scenario-based flight training format.
Deconstructing Free Energies in the Law of Matching Water Affinities.
Shi, Yu; Beck, Thomas
2017-03-09
The law of matching water affinities (LMWA) is explored in classical molecular dynamics simulations of several alkali halide ion pairs, spanning the size range from small kosmotropes to large chaotropes. The ion-ion potentials of mean force (PMFs) are computed using three methods: the local molecular field theory (LMFT), the weighted histogram analysis method (WHAM), and integration of the average force. All three methods produce the same total PMF for a given ion pair. In addition, LMFT-based partitioning into van der Waals and local and far-field electrostatic free energies and assessment of the enthalpic, entropic, and ion-water components yield insights into the origins of the observed free energy profiles in water. The results highlight the importance of local electrostatic interactions in determining the shape of the PMFs, while longer-ranged interactions enhance the overall ion-ion attraction, as expected in a dielectric continuum model. The association equilibrium constants are estimated from the smooth WHAM curves and compared to available experimental conductance data. By examining the variations in the average hydration numbers of ions with ion-ion distance, a correlation of the water structure in the hydration shells with the free energy features is found.
NASA Astrophysics Data System (ADS)
Huang, J. J.; Lin, S. C.; Löwemark, L.; Liou, Y. H.; Chang, Q. M.; Chang, T. K.; Wei, K. Y.; Croudace, I. W. C.
2017-12-01
Due to the rapid industrial expansion, environments are subject to irregular fluctuations and spatial distributions in pollutant concentrations. This study proposes to use ion exchange resin accompanied with the XRF-scanning technique to monitor environmental pollution. As a passive sampling sorbent, the use of ion exchange resin provides a rapid, low cost and simple method to detect episodic pollution signals with a high spatial sampling density. In order to digest large quantities of samples, the fast and non-destructive Itrax-XRF core scanner has been introduced to assess elemental concentrations in the resin samples. Although the XRF scanning results are often considered as a semi-quantitative measurement due to possible absorption or scattering caused by the physical variabilities of scanned materials, the use of resin can minimize such influences owing to the standarization of the sample matrix. In this study, 17 lab-prepared standard resin samples were scanned with the Itrax-XRF core scanner (at 100 s exposure time with the Mo-tube) and compared with the absolute elemental concentrations. Six elements generally used in pollution studies (Cr, Mn, Ni, Cu, Zn, and Pb) were selected, and their regression lines and correlation coefficients were determined. In addition, 5 standard resin samples were scanned at different exposure time settings (1 s, 5 s, 15 s, 30 s, 100 s) to address the influence of exposure time on the accuracy of the measurements. The results show that within the test range (from few ppm to thousands ppm), the correlation coefficients are higher than 0.97, even at the shortest exposure time (1 s). Furthermore, a pilot field survey with 30 resin samples has been conducted in a potentially polluted farm area in central Taiwan to demonstrate the feasibility of this novel approach. The polluted hot zones could be identified and the properties and sources of wastewater pollution can therefore be traced over large areas for the purposes of environmental monitoring and environmental forensics.
Monitoring inter-channel nonlinearity based on differential pilot
NASA Astrophysics Data System (ADS)
Wang, Wanli; Yang, Aiying; Guo, Peng; Lu, Yueming; Qiao, Yaojun
2018-06-01
We modify and simplify the inter-channel nonlinearity (NL) estimation method by using differential pilot. Compared to previous works, the inter-channel NL estimation method we propose has much lower complexity and does not need modification of the transmitter. The performance of inter-channel NL monitoring with different launch power is tested. For both QPSK and 16QAM systems with 9 channels, the estimation error of inter-channel NL is lower than 1 dB when the total launch power is bigger than 12 dBm after 1000 km optical transmission. At last, we compare our inter-channel NL estimation method with other methods.
Manganese oxide helices, rings, strands, and films, and methods for their preparation
Suib, Steven L.; Giraldo, Oscar; Marquez, Manuel; Brock, Stephanie
2003-01-07
Methods for the preparation of mixed-valence manganese oxide compositions with quaternary ammonium ions are described. The compositions self-assemble into helices, rings, and strands without any imposed concentration gradient. These helices, rings, and strands, as well as films having the same composition, undergo rapid ion exchange to replace the quaternary ammonium ions with various metal ions. And the metal-ion-containing manganese oxide compositions so formed can be heat treated to form semi-conducting materials with high surface areas.
Ion current detector for high pressure ion sources for monitoring separations
Smith, R.D.; Wahl, J.H.; Hofstadler, S.A.
1996-08-13
The present invention relates generally to any application involving the monitoring of signal arising from ions produced by electrospray or other high pressure (>100 torr) ion sources. The present invention relates specifically to an apparatus and method for the detection of ions emitted from a capillary electrophoresis (CE) system, liquid chromatography, or other small-scale separation methods. And further, the invention provides a very simple diagnostic as to the quality of the separation and the operation of an electrospray source. 7 figs.
Ion current detector for high pressure ion sources for monitoring separations
Smith, Richard D.; Wahl, Jon H.; Hofstadler, Steven A.
1996-01-01
The present invention relates generally to any application involving the monitoring of signal arising from ions produced by electrospray or other high pressure (>100 torr) ion sources. The present invention relates specifically to an apparatus and method for the detection of ions emitted from a capillary electrophoresis (CE) system, liquid chromatography, or other small-scale separation methods. And further, the invention provides a very simple diagnostic as to the quality of the separation and the operation of an electrospray source.
ERIC Educational Resources Information Center
Rees, Liz; Clark-Stone, Sam
2006-01-01
In this pilot study, a number of different methods of identifying young people with eating disorders in schools were compared. Pupils aged 16-18 years from 3 schools in the South West of the UK participated (389 boys and 374 girls in total). A self-report questionnaire (EDE-Q) was found to be the most effective method of case identification.…
US Forest Service, Northeastern Area, State and Private Forestry
2006-01-01
This report highlights findings from the first statewide urban forest health monitoring pilot study conducted in the State of Indiana in 2002. The report is in two parts. Part One summarizes analysis of the field methods and data collected on the urban nonforest plots of one panel in Indiana, and Part Two expands these data to statewide urban forest estimates with the...
Matt Lake; Philip Marshall; Manfred Mielke; Anne Buckelew Cumming; Daniel Twardus
2006-01-01
This report highlights findings from the first statewide urban forest health monitoring pilot study conducted in the State of Indiana in 2002. The report is in two parts: Part One summarizes analysis of the field methods and data collected on the urban nonforest plots of one panel in Indiana, and Part Two expands these data to statewide urban forest estimates with the...
Method for ion implantation induced embedded particle formation via reduction
Hampikian, Janet M; Hunt, Eden M
2001-01-01
A method for ion implantation induced embedded particle formation via reduction with the steps of ion implantation with an ion/element that will chemically reduce the chosen substrate material, implantation of the ion/element to a sufficient concentration and at a sufficient energy for particle formation, and control of the temperature of the substrate during implantation. A preferred embodiment includes the formation of particles which are nano-dimensional (<100 m-n in size). The phase of the particles may be affected by control of the substrate temperature during and/or after the ion implantation process.
Development of fast-release solid catchers for rare isotopes
NASA Astrophysics Data System (ADS)
Nolen, Jerry; Greene, John; Elam, Jeffrey; Mane, Anil; Sampathkumaran, Uma; Winter, Raymond; Hess, David; Mushfiq, Mohammad; Stracener, Daniel; Wiendenhoever, Ingo
2015-04-01
Porous solid catchers of rare isotopes are being developed for use at high power heavy ion accelerator facilities such as RIKEN, FRIB, and RISP. Compact solid catchers are complementary to helium gas catchers for parasitic harvesting of rare isotopes in the in-flight separators. They are useful for short lived isotopes for basic nuclear physics research and longer-lived isotopes for off-line applications. Solid catchers can operate effectively with high intensity secondary beams, e.g. >> 1E10 atoms/s with release times as short as 10-100 milliseconds. A new method using a very sensitive and efficient RGA has been commissioned off-line at Argonne and is currently being shipped to Florida State University for in-beam measurements of the release curves using stable beams. The same porous solid catcher technology is also being evaluated for use in targets for the production of medical isotopes such as 211-At. Research supported by the U.S. DOE Office of Nuclear Physics under the SBIR Program and Contract # DE-AC02-06CH11357 and a University of Chicago Comprehensive Cancer Center/ANL Pilot Project.
Extensive sequencing of seven human genomes to characterize benchmark reference materials
Zook, Justin M.; Catoe, David; McDaniel, Jennifer; Vang, Lindsay; Spies, Noah; Sidow, Arend; Weng, Ziming; Liu, Yuling; Mason, Christopher E.; Alexander, Noah; Henaff, Elizabeth; McIntyre, Alexa B.R.; Chandramohan, Dhruva; Chen, Feng; Jaeger, Erich; Moshrefi, Ali; Pham, Khoa; Stedman, William; Liang, Tiffany; Saghbini, Michael; Dzakula, Zeljko; Hastie, Alex; Cao, Han; Deikus, Gintaras; Schadt, Eric; Sebra, Robert; Bashir, Ali; Truty, Rebecca M.; Chang, Christopher C.; Gulbahce, Natali; Zhao, Keyan; Ghosh, Srinka; Hyland, Fiona; Fu, Yutao; Chaisson, Mark; Xiao, Chunlin; Trow, Jonathan; Sherry, Stephen T.; Zaranek, Alexander W.; Ball, Madeleine; Bobe, Jason; Estep, Preston; Church, George M.; Marks, Patrick; Kyriazopoulou-Panagiotopoulou, Sofia; Zheng, Grace X.Y.; Schnall-Levin, Michael; Ordonez, Heather S.; Mudivarti, Patrice A.; Giorda, Kristina; Sheng, Ying; Rypdal, Karoline Bjarnesdatter; Salit, Marc
2016-01-01
The Genome in a Bottle Consortium, hosted by the National Institute of Standards and Technology (NIST) is creating reference materials and data for human genome sequencing, as well as methods for genome comparison and benchmarking. Here, we describe a large, diverse set of sequencing data for seven human genomes; five are current or candidate NIST Reference Materials. The pilot genome, NA12878, has been released as NIST RM 8398. We also describe data from two Personal Genome Project trios, one of Ashkenazim Jewish ancestry and one of Chinese ancestry. The data come from 12 technologies: BioNano Genomics, Complete Genomics paired-end and LFR, Ion Proton exome, Oxford Nanopore, Pacific Biosciences, SOLiD, 10X Genomics GemCode WGS, and Illumina exome and WGS paired-end, mate-pair, and synthetic long reads. Cell lines, DNA, and data from these individuals are publicly available. Therefore, we expect these data to be useful for revealing novel information about the human genome and improving sequencing technologies, SNP, indel, and structural variant calling, and de novo assembly. PMID:27271295
Method for improving the durability of ion insertion materials
Lee, Se-Hee; Tracy, C. Edwin; Cheong, Hyeonsik M.
2002-01-01
The invention provides a method of protecting an ion insertion material from the degradative effects of a liquid or gel-type electrolyte material by disposing a protective, solid ion conducting, electrically insulating, layer between the ion insertion layer and the liquid or gel-type electrolyte material. The invention further provides liquid or gel-type electrochemical cells having improved durability having a pair of electrodes, a pair of ion insertion layers sandwiched between the pair of electrodes, a pair of solid ion conducting layers sandwiched between the ion insertion layers, and a liquid or gel-type electrolyte material disposed between the solid ion conducting layers, where the solid ion conducting layer minimizes or prevents degradation of the faces of the ion insertion materials facing the liquid or gel-type electrolyte material. Electrochemical cells of this invention having increased durability include secondary lithium batteries and electrochromic devices.
Polyamines and inorganic ions extracted from woody tissues by freeze-thawing
Rakesh Minocha; Walter C. Shortle
1994-01-01
A simple and fast method for extraction of major inorganic ions (Ca, Mg, Mn, K, and P) and cellular polyamines from small quantities of wood and woody plant tissues is described. The method involves repeated freezing and thawing of samples instead of homogenization or wet ash digestion. The efficiency of extraction of both polyamines and inorganic ions by these methods...
Methods of obtaining a uniform volume concentration of implanted ions
NASA Astrophysics Data System (ADS)
Reutov, V. F.
1998-05-01
Three simple practical methods of irradiation with high energy particles (>5 MeV/n), providing the conditions of obtaining a uniform volume concentration of the implanted ions in the massive samples are described in the present paper. Realization of the condition of two-sided irradiation of a plane sample during its rotation in the flux of the projectiles is the basis of the first method. The use of free air as a filter with varying absorbent ability due to the movement of the irradiated sample along ion beam brought to the atmosphere is at the basis of the second method of uniform ion alloying. The third method of obtaining a uniform volume concentration of the implanted ions in a massive sample consists of sample irradiation through the absorbent filter in the shape of a foil curved according to the parabolic law moving along its surface. The first method is the most effective for obtaining a great number of the samples, for mechanical tests, for example, the second one - for irradiation in different gaseous media, the third one - for obtaining high concentration of the implanted ions under controlled (regulated) thermal and deformation conditions.
Focused ion beam source method and apparatus
Pellin, Michael J.; Lykke, Keith R.; Lill, Thorsten B.
2000-01-01
A focused ion beam having a cross section of submicron diameter, a high ion current, and a narrow energy range is generated from a target comprised of particle source material by laser ablation. The method involves directing a laser beam having a cross section of critical diameter onto the target, producing a cloud of laser ablated particles having unique characteristics, and extracting and focusing a charged particle beam from the laser ablated cloud. The method is especially suited for producing focused ion beams for semiconductor device analysis and modification.
Shapiro, Andrew Philip; Thornton, Roy Fred; Salvo, Joseph James
2003-01-01
The present invention provides a method for treating contaminated media. The method comprises introducing remediating ions consisting essentially of ferrous ions, and being peroxide-free, in the contaminated media; applying a potential difference across the contaminated media to cause the remediating ions to migrate into contact with contaminants in the contaminated media; chemically degrading contaminants in the contaminated media by contact with the remediating ions; monitoring the contaminated media for degradation products of the contaminants; and controlling the step of applying the potential difference across the contaminated media in response to the step of monitoring.
Flow injection trace gas analysis method for on-site determination of organoarsenicals
Aldstadt, J.H. III
1997-06-24
A method is described for real-time determination of the concentration of Lewisite in the ambient atmosphere, the method includes separating and collecting a Lewisite sample from the atmosphere in a collection chamber, converting the collected Lewisite to an arsenite ion solution sample, pumping the arsenite ion containing sample to an electrochemical detector connected to the collection chamber, and electrochemically detecting the converted arsenite ions in the sample, whereby the concentration of arsenite ions detected is proportional to the concentration of Lewisite in the atmosphere. 2 figs.
NASA Technical Reports Server (NTRS)
Hess, R. A.
1976-01-01
Paramount to proper utilization of electronic displays is a method for determining pilot-centered display requirements. Display design should be viewed fundamentally as a guidance and control problem which has interactions with the designer's knowledge of human psychomotor activity. From this standpoint, reliable analytical models of human pilots as information processors and controllers can provide valuable insight into the display design process. A relatively straightforward, nearly algorithmic procedure for deriving model-based, pilot-centered display requirements was developed and is presented. The optimal or control theoretic pilot model serves as the backbone of the design methodology, which is specifically directed toward the synthesis of head-down, electronic, cockpit display formats. Some novel applications of the optimal pilot model are discussed. An analytical design example is offered which defines a format for the electronic display to be used in a UH-1H helicopter in a landing approach task involving longitudinal and lateral degrees of freedom.
An assessment of predominant causal factors of pilot deviations that contribute to runway incursions
NASA Astrophysics Data System (ADS)
Campbell, Denado M.
The aim of this study was to identify predominant causal factors of pilot deviations in runway incursions over a two-year period. Runway incursion reports were obtained from NASA's Aviation Safety Reporting System (ASRS), and a qualitative method was used by classifying and coding each report to a specific causal factor(s). The causal factors that were used were substantiated by research from the Aircraft Owner's and Pilot's Association that found that these causal factors were the most common in runway incursion incidents and accidents. An additional causal factor was also utilized to determine the significance of pilot training in relation to runway incursions. From the reports examined, it was found that miscommunication and situational awareness have the greatest impact on pilots and are most often the major causes of runway incursions. This data can be used to assist airports, airlines, and the FAA to understand trends in pilot deviations, and to find solutions for specific problem areas in runway incursion incidents.
Entropy, instrument scan and pilot workload
NASA Technical Reports Server (NTRS)
Tole, J. R.; Stephens, A. T.; Vivaudou, M.; Harris, R. L., Jr.; Ephrath, A. R.
1982-01-01
Correlation and information theory which analyze the relationships between mental loading and visual scanpath of aircraft pilots are described. The relationship between skill, performance, mental workload, and visual scanning behavior are investigated. The experimental method required pilots to maintain a general aviation flight simulator on a straight and level, constant sensitivity, Instrument Landing System (ILS) course with a low level of turbulence. An additional periodic verbal task whose difficulty increased with frequency was used to increment the subject's mental workload. The subject's looppoint on the instrument panel during each ten minute run was computed via a TV oculometer and stored. Several pilots ranging in skill from novices to test pilots took part in the experiment. Analysis of the periodicity of the subject's instrument scan was accomplished by means of correlation techniques. For skilled pilots, the autocorrelation of instrument/dwell times sequences showed the same periodicity as the verbal task. The ability to multiplex simultaneous tasks increases with skill. Thus autocorrelation provides a way of evaluating the operator's skill level.
Effectively Transforming IMC Flight into VMC Flight: An SVS Case Study
NASA Technical Reports Server (NTRS)
Glaab, Louis J.; Hughes, Monic F.; Parrish, Russell V.; Takallu, Mohammad A.
2006-01-01
A flight-test experiment was conducted using the NASA LaRC Cessna 206 aircraft. Four primary flight and navigation display concepts, including baseline and Synthetic Vision System (SVS) concepts, were evaluated in the local area of Roanoke Virginia Airport, flying visual and instrument approach procedures. A total of 19 pilots, from 3 pilot groups reflecting the diverse piloting skills of the GA population, served as evaluation pilots. Multi-variable Discriminant Analysis was applied to three carefully selected and markedly different operating conditions with conventional instrumentation to provide an extension of traditional analysis methods as well as provide an assessment of the effectiveness of SVS displays to effectively transform IMC flight into VMC flight.
Using Visualization in Cockpit Decision Support Systems
NASA Technical Reports Server (NTRS)
Aragon, Cecilia R.
2005-01-01
In order to safely operate their aircraft, pilots must make rapid decisions based on integrating and processing large amounts of heterogeneous information. Visual displays are often the most efficient method of presenting safety-critical data to pilots in real time. However, care must be taken to ensure the pilot is provided with the appropriate amount of information to make effective decisions and not become cognitively overloaded. The results of two usability studies of a prototype airflow hazard visualization cockpit decision support system are summarized. The studies demonstrate that such a system significantly improves the performance of helicopter pilots landing under turbulent conditions. Based on these results, design principles and implications for cockpit decision support systems using visualization are presented.
Baird, Zane; Wei, Pu; Cooks, R Graham
2015-02-07
A method is presented in which ions are generated and manipulated in the ambient environment using polymeric electrodes produced with a consumer-grade 3D printer. The ability to focus, separate, react, and detect ions in the ambient environment is demonstrated and the data agree well with simulated ion behaviour.
AVCS Simulator Test Plan and Design Guide
NASA Technical Reports Server (NTRS)
Shelden, Stephen
2001-01-01
Internal document for communication of AVCS direction and documentation of simulator functionality. Discusses methods for AVCS simulation evaluation of pilot functions, implementation strategy of varying functional representation of pilot tasks (by instantiations of a base AVCS to reasonably approximate the interface of various vehicles -- e.g. Altair, GlobalHawk, etc.).
A PILOT STUDY TO COMPARE MICROBIAL AND CHEMICAL INDICATORS OF HUMAN FECAL CONTAMINATION IN WATER
Limitations exist in applying traditional microbial methods for the detection of human fecal contamination of water. A pilot study was undertaken to compare the microbial and chemical indicators of human fecal contamination of water. Sixty-four water samples were collected in O...
75 FR 30908 - Notice of Funds Availability for FY 2010
Federal Register 2010, 2011, 2012, 2013, 2014
2010-06-02
... for the FY 2010 funding round of the Financial Education and Counseling (FEC) Pilot Program... Counseling Services to Prospective Homebuyers. The goals of grants that are awarded through the FEC Pilot Program are to identify successful methods of Financial Education and Counseling Services that result in...
Reducing State Communication Anxiety for Public Speakers: An Energy Psychology Pilot Study
ERIC Educational Resources Information Center
Fitch, John, III; Schmuldt, Laura; Rudick, Karen L.
2011-01-01
This mixed-method pilot study investigates the efficacy of implementing primordial energy activation and transcendence to address public speaking anxiety. Speech anxiety was significantly reduced from pretest to posttest, as measured by the Communication Anxiety Inventory State. Suggestions for future research, limitations of the current study,…
Examining Informal Learning in Commercial Airline Pilots' Communities of Practice
ERIC Educational Resources Information Center
Corns, Kevin M.
2014-01-01
A pragmatic sequential mixed methods research methodology was used to examine commercial airline pilots' (N =156) types and frequencies of informal learning activities, perceptions of workplace informal learning, and opinions on how organizations should support workplace informal learning outside of the formal learning environment. This study…
PILOT IN SITU CAPPING PROJECT FOR PALOS VERDES SHELF CONTAMINATED SEDIMENTS
The Palos Verdes Shelf Pilot Capping Project will evaluate the short-term results of capping the DDT- and PCB-contaminated sediment with clean sediment. It will also determine how these results are affected by variables such as cap material, placement method and water depth. The ...
Mood Management Intervention for College Smokers with Elevated Depressive Symptoms: A Pilot Study
ERIC Educational Resources Information Center
Schleicher, Holly E.; Harris, Kari Jo; Campbell, Duncan G.; Harrar, Solomon W.
2012-01-01
Objective: This pilot study examined smoking reduction and cessation among college smokers with elevated depressive symptomatology participating in a group-based behavioral counseling, mood management, and motivational enhancement combined intervention (CBT). Participants and Methods: Fifty-eight smokers (smoked 6 days in the past 30) were…
Pilot interaction with automated airborne decision making systems
NASA Technical Reports Server (NTRS)
Rouse, W. B.
1981-01-01
The role of the pilot and crew for future aircraft is discussed. Fifteen formal experimental studies and the development of a variety of models of human behavior based on queueing history, pattern recognition methods, control theory, fuzzy set theory, and artificial intelligence concepts are presented. L.F.M.
Group Therapy for Children after Homicide and Violence: A Pilot Study
ERIC Educational Resources Information Center
Salloum, Alison
2008-01-01
Objective: This pilot study evaluated a group intervention designed to reduce posttraumatic stress among children after homicide and/or violence. Method: Employing a secondary data analysis of 117 participants in 21 group interventions, pretest and posttest differences in posttraumatic stress levels and between child witnesses and nonwitnesses,…
2006 pilot survey for Phytophthora ramorum in forest streams in the USA
S.W. Oak; J. Hwang; S.N. Jeffers; B.M. Tkacz
2008-01-01
Methods for detecting Phytophthora ramorum and other Phytophthora species with rhododendron leaf baits were pilot tested in high-risk watersheds in 11 states for the purpose of recommending a national survey protocol. Ninety streams, including 14 draining P. ramorum.-endemic areas, yielded 587 baiting chances....
Perceptual-Motor and Cognitive Performance Task-Battery for Pilot Selection
1981-01-01
processing. Basic researchers in cognitive phychology have become discouraged with the inability of numerous models to consider and account for individual...attention in the use of cues in verbal problem-solving. Journal of Personality, 197?, 40, 226-241. Mensh, I. N. Pilot selection by phychological methods
Two analytical methods were developed and refined for the detection and quantitation of two groups of endocrine-disrupting chemicals (EDCs) in the liquid matrixes of two pilot-scale municipal wastewater treatment plants. The targeted compounds are seven sex hormones (estradiol, ...
ERIC Educational Resources Information Center
Hill, Anne J.; Theodoros, Deborah G.; Russell, Trevor G.; Cahill, Louise M.; Ward, Elizabeth C.; Clark, Kathy M.
2006-01-01
Purpose: This pilot study explored the feasibility and effectiveness of an Internet-based telerehabilitation application for the assessment of motor speech disorders in adults with acquired neurological impairment. Method: Using a counterbalanced, repeated measures research design, 2 speech-language pathologists assessed 19 speakers with…
2013-01-01
Background The goal of many proteomics experiments is to determine the abundance of proteins in biological samples, and the variation thereof in various physiological conditions. High-throughput quantitative proteomics, specifically label-free LC-MS/MS, allows rapid measurement of thousands of proteins, enabling large-scale studies of various biological systems. Prior to analyzing these information-rich datasets, raw data must undergo several computational processing steps. We present a method to address one of the essential steps in proteomics data processing - the matching of peptide measurements across samples. Results We describe a novel method for label-free proteomics data alignment with the ability to incorporate previously unused aspects of the data, particularly ion mobility drift times and product ion information. We compare the results of our alignment method to PEPPeR and OpenMS, and compare alignment accuracy achieved by different versions of our method utilizing various data characteristics. Our method results in increased match recall rates and similar or improved mismatch rates compared to PEPPeR and OpenMS feature-based alignment. We also show that the inclusion of drift time and product ion information results in higher recall rates and more confident matches, without increases in error rates. Conclusions Based on the results presented here, we argue that the incorporation of ion mobility drift time and product ion information are worthy pursuits. Alignment methods should be flexible enough to utilize all available data, particularly with recent advancements in experimental separation methods. PMID:24341404
Benjamin, Ashlee M; Thompson, J Will; Soderblom, Erik J; Geromanos, Scott J; Henao, Ricardo; Kraus, Virginia B; Moseley, M Arthur; Lucas, Joseph E
2013-12-16
The goal of many proteomics experiments is to determine the abundance of proteins in biological samples, and the variation thereof in various physiological conditions. High-throughput quantitative proteomics, specifically label-free LC-MS/MS, allows rapid measurement of thousands of proteins, enabling large-scale studies of various biological systems. Prior to analyzing these information-rich datasets, raw data must undergo several computational processing steps. We present a method to address one of the essential steps in proteomics data processing--the matching of peptide measurements across samples. We describe a novel method for label-free proteomics data alignment with the ability to incorporate previously unused aspects of the data, particularly ion mobility drift times and product ion information. We compare the results of our alignment method to PEPPeR and OpenMS, and compare alignment accuracy achieved by different versions of our method utilizing various data characteristics. Our method results in increased match recall rates and similar or improved mismatch rates compared to PEPPeR and OpenMS feature-based alignment. We also show that the inclusion of drift time and product ion information results in higher recall rates and more confident matches, without increases in error rates. Based on the results presented here, we argue that the incorporation of ion mobility drift time and product ion information are worthy pursuits. Alignment methods should be flexible enough to utilize all available data, particularly with recent advancements in experimental separation methods.
Effects of 12C6+ Heavy Ion Radiation on Dendritic Cells Function
Zhang, Pei; Hu, Xuguang; Liu, Bin; Liu, Zhe; Liu, Cong; Cai, Jianming; Gao, Fu; Li, Bailong
2018-01-01
Background Carbon ion radiotherapy has been shown to be more effective in cancer radiotherapy than photon irradiation. Influence of carbon ion radiation on cancer microenvironment is very important for the outcomes of radiotherapy. Tumor-infiltrating dendritic cells (DCs) play critical roles in cancer antigen processing and antitumor immunity. However, there is scant literature covering the effects of carbon ion radiation on DCs. In this study, we aimed to uncover the impact of carbon ion irradiation on bone marrow derived DCs. Material/Methods Bone marrow cells were co-cultured with GM-CSF and IL-4 for seven days, and the population of DCs was confirmed with flow cytometry. We used an Annexin V and PI staining method to detect cell apoptosis. Endocytosis assay of DCs was determined by using a flow cytometry method. DCs migration capacity was tested by a Transwell method. We also used ELISA assay and western blotting assay to examine the cytokines and protein expression, respectively. Results Our data showed that carbon ion radiation induced apoptosis in both immature and mature DCs. After irradiation, the endocytosis and migration capacity of DCs was also impaired. Interestingly, carbon irradiation triggered a burst of IFN-γ and IL-12 in LPS or CpG treated DCs, which provide novel insights into the combination of immunotherapy and carbon ion radiotherapy. Finally, we found that carbon ion irradiation induced apoptosis and migration suppression was p38 dependent. Conclusions Our present study demonstrated that carbon ion irradiation induced apoptosis in DCs, and impaired DCs function mainly through the p38 signaling pathway. Carbon ion irradiation also triggered anti-tumor cytokines secretion. This work provides novel information of carbon ion radiotherapy in DCs, and also provides new insights on the combination of immune adjuvant and carbon ion radiotherapy. PMID:29525808
Prediction of helicopter simulator sickness
DOE Office of Scientific and Technical Information (OSTI.GOV)
Horn, R.D.; Birdwell, J.D.; Allgood, G.O.
1990-01-01
Machine learning methods from artificial intelligence are used to identify information in sampled accelerometer signals and associative behavioral patterns which correlates pilot simulator sickness with helicopter simulator dynamics. These simulators are used to train pilots in fundamental procedures, tactics, and response to emergency conditions. Simulator sickness induced by these systems represents a risk factor to both the pilot and manufacturer. Simulator sickness symptoms are closely aligned with those of motion sickness. Previous studies have been performed by behavioral psychologists using information gathered with surveys and motor skills performance measures; however, the results are constrained by the limited information which ismore » accessible in this manner. In this work, accelerometers were installed in the simulator cab, enabling a complete record of flight dynamics and the pilot's control response as a function of time. Given the results of performance measures administered to detect simulator sickness symptoms, the problem was then to find functions of the recorded data which could be used to help predict the simulator sickness level and susceptibility. Methods based upon inductive inference were used, which yield decision trees whose leaves indicate the degree of simulator-induced sickness. The long-term goal is to develop a gauge'' which can provide an on-line prediction of simulator sickness level, given a pilot's associative behavioral patterns (learned expectations). This will allow informed decisions to be made on when to terminate a hop and provide an effective basis for determining training and flight restrictions placed upon the pilot after simulator use. 6 refs., 6 figs.« less
NASA Astrophysics Data System (ADS)
Iigaya, Kiyohito
A robust, fast and accurate protection system based on pilot protection concept was developed previously and a few alterations in that algorithm were made to make it faster and more reliable and then was applied to smart distribution grids to verify the results for it. The new 10 sample window method was adapted into the pilot protection program and its performance for the test bed system operation was tabulated. Following that the system comparison between the hardware results for the same algorithm and the simulation results were compared. The development of the dual slope percentage differential method, its comparison with the 10 sample average window pilot protection system and the effects of CT saturation on the pilot protection system are also shown in this thesis. The implementation of the 10 sample average window pilot protection system is done to multiple distribution grids like Green Hub v4.3, IEEE 34, LSSS loop and modified LSSS loop. Case studies of these multi-terminal model are presented, and the results are also shown in this thesis. The result obtained shows that the new algorithm for the previously proposed protection system successfully identifies fault on the test bed and the results for both hardware and software simulations match and the response time is approximately less than quarter of a cycle which is fast as compared to the present commercial protection system and satisfies the FREEDM system requirement.
Effective doping of low energy ions into superfluid helium droplets
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, Jie; Chen, Lei; Freund, William M.
2015-08-21
We report a facile method of doping cations from an electrospray ionization (ESI) source into superfluid helium droplets. By decelerating and stopping the ion pulse of reserpine and substance P from an ESI source in the path of the droplet beam, about 10{sup 4} ion-doped droplets (one ion per droplet) can be recorded, corresponding to a pickup efficiency of nearly 1 out of 1000 ions. We attribute the success of this simple approach to the long residence time of the cations in the droplet beam. The resulting size of the doped droplets, on the order of 10{sup 5}/droplet, is measuredmore » using deflection and retardation methods. Our method does not require an ion trap in the doping region, which significantly simplifies the experimental setup and procedure for future spectroscopic and diffraction studies.« less
Calejo, Isabel; Moreira, Nathalie; Araújo, Ana Margarida; Carvalho, Márcia; Bastos, Maria de Lourdes; de Pinho, Paula Guedes
2016-02-01
A new and simple analytical approach consisting of an automated headspace solid-phase microextraction (HS-SPME) sampler coupled to gas chromatography-ion trap/mass spectrometry detection (GC-IT/MS) with a prior derivatization step with O-(2,3,4,5,6-pentafluorobenzyl)hydroxylamine hydrochloride (PFBHA) was developed to detect volatile carbonyl metabolites with low molecular weights in human urine. A central composite design (CCD) was used to optimise the PFBHA concentration and extraction conditions that affect the efficiency of the SPME procedure. With a sample volume of 1 mL, optimal conditions were achieved by adding 300 mg/L of PFBHA and allowing the sample to equilibrate for 6 min at 62°C and then extracting the samples for 51 min at the same temperature, using a divinylbenzene/polydimethylsiloxane (DVB/PDMS) fibre. The method allowed the simultaneous identification and quantification of 44 carbonyl compounds consisting of aldehydes, dialdehydes, heterocyclic aldehydes and ketones. The method was validated with regards to the linearity, inter- and intra-day precision and accuracy. The detection limits ranged from 0.009 to 0.942 ng/mL, except for 4-hydroxy-2-nonenal (15 ng/mL), and the quantification limits varied from 0.029 to 1.66 ng/mL, except for butanal (2.78 ng/mL), 2-butanone (2.67 ng/mL), 4-heptanone (3.14 ng/mL) and 4-hydroxy-2-nonenal (50.0 ng/mL). The method accuracy was satisfactory, with recoveries ranging from 90 to 107%. The proof of applicability of the methodology was performed in a pilot target analysis of urine samples obtained from 18 healthy smokers and 18 healthy non-smokers (control group). Chemometric supervised analysis was performed using the volatile patterns acquired for these samples and clearly showed the potential of the volatile carbonyl profiles to discriminate urine from smoker and non-smoker subjects. 5-Methyl-2-furfural (p<0.0001), 2-methylpropanal, nonanal and 2-methylbutanal (p<0.05) were identified as potentially useful biomarkers to identify smoking habits. Copyright © 2015 Elsevier B.V. All rights reserved.
Vision improvement in pilots with presbyopia following perceptual learning.
Sterkin, Anna; Levy, Yuval; Pokroy, Russell; Lev, Maria; Levian, Liora; Doron, Ravid; Yehezkel, Oren; Fried, Moshe; Frenkel-Nir, Yael; Gordon, Barak; Polat, Uri
2017-11-24
Israeli Air Force (IAF) pilots continue flying combat missions after the symptoms of natural near-vision deterioration, termed presbyopia, begin to be noticeable. Because modern pilots rely on the displays of the aircraft control and performance instruments, near visual acuity (VA) is essential in the cockpit. We aimed to apply a method previously shown to improve visual performance of presbyopes, and test whether presbyopic IAF pilots can overcome the limitation imposed by presbyopia. Participants were selected by the IAF aeromedical unit as having at least initial presbyopia and trained using a structured personalized perceptual learning method (GlassesOff application), based on detecting briefly presented low-contrast Gabor stimuli, under the conditions of spatial and temporal constraints, from a distance of 40 cm. Our results show that despite their initial visual advantage over age-matched peers, training resulted in robust improvements in various basic visual functions, including static and temporal VA, stereoacuity, spatial crowding, contrast sensitivity and contrast discrimination. Moreover, improvements generalized to higher-level tasks, such as sentence reading and aerial photography interpretation (specifically designed to reflect IAF pilots' expertise in analyzing noisy low-contrast input). In concert with earlier suggestions, gains in visual processing speed are plausible to account, at least partially, for the observed training-induced improvements. Copyright © 2017 Elsevier Ltd. All rights reserved.
Integrated care pilot in north-west London: a mixed methods evaluation
Curry, Natasha; Harris, Matthew; Gunn, Laura H.; Pappas, Yannis; Blunt, Ian; Soljak, Michael; Mastellos, Nikolaos; Holder, Holly; Smith, Judith; Majeed, Azeem; Ignatowicz, Agnieszka; Greaves, Felix; Belsi, Athina; Costin-Davis, Nicola; Jones Nielsen, Jessica D.; Greenfield, Geva; Cecil, Elizabeth; Patterson, Susan; Car, Josip; Bardsley, Martin
2013-01-01
Introduction This paper provides the results of a year-long evaluation of a large-scale integrated care pilot in north-west London. The pilot aimed to integrate care across primary, acute, community, mental health and social care for people with diabetes and/or those aged 75+ through care planning, multidisciplinary case reviews, information sharing and project management support. Methods The evaluation team conducted qualitative studies of change at organisational, clinician and patient levels (using interviews, focus groups and a survey); and quantitative analysis of change in service use and patient-level clinical outcomes (using patient-level datasets and a matched control study). Results The pilot had successfully engaged provider organisations, created a shared strategic vision and established governance structures. However, the engagement of clinicians was variable and there was no evidence to date of significant reductions in emergency admissions. There was some evidence of changes in care processes. Conclusion Although the pilot has demonstrated the beginnings of large-scale change, it remains in the early stages and faces significant challenges as it seeks to become sustainable for the longer term. It is critical that National Health Service managers and clinicians have realistic expectations of what can be achieved in a relatively short period of time. PMID:24167455
Wang, Yang; Liu, Fang; Li, Peng; He, Chengwei; Wang, Ruibing; Su, Huanxing; Wan, Jian-Bo
2016-07-13
Pseudotargeted metabolomics is a novel strategy integrating the advantages of both untargeted and targeted methods. The conventional pseudotargeted metabolomics required two MS instruments, i.e., ultra-high performance liquid chromatography/quadrupole-time- of-flight mass spectrometry (UHPLC/Q-TOF MS) and UHPLC/triple quadrupole mass spectrometry (UHPLC/QQQ-MS), which makes method transformation inevitable. Furthermore, the picking of ion pairs from thousands of candidates and the swapping of the data between two instruments are the most labor-intensive steps, which greatly limit its application in metabolomic analysis. In the present study, we proposed an improved pseudotargeted metabolomics method that could be achieved on an UHPLC/Q-TOF/MS instrument operated in the multiple ion monitoring (MIM) mode with time-staggered ion lists (tsMIM). Full scan-based untargeted analysis was applied to extract the target ions. After peak alignment and ion fusion, a stepwise ion picking procedure was used to generate the ion lists for subsequent single MIM and tsMIM. The UHPLC/Q-TOF tsMIM MS-based pseudotargeted approach exhibited better repeatability and a wider linear range than the UHPLC/Q-TOF MS-based untargeted metabolomics method. Compared to the single MIM mode, the tsMIM significantly increased the coverage of the metabolites detected. The newly developed method was successfully applied to discover plasma biomarkers for alcohol-induced liver injury in mice, which indicated its practicability and great potential in future metabolomics studies. Copyright © 2016 Elsevier B.V. All rights reserved.
Wang, Tianshu
2006-01-01
This study has developed a method for measuring the enthalpy of volatilization (Delta(vol)H) of a compound in a dilute solution via ion-molecule reactions and gas-phase analysis using selected ion flow tube mass spectrometry (SIFT-MS). The Delta(vol)H/R value was obtained using an equation with three variant forms either from the headspace concentration of the solution or from individual product ion(s). Under certain experimental conditions, the equation has the simplest form [formula: see text], where R is the gas constant (8.314 J . mol(-1) . K(-1)), i(n) and I are the respective product and precursor ion count rates, and T is the temperature of the solution. As an example, a series of 27.0 micromol/L aqueous solutions of acetone was analyzed over a temperature range of 25-50 degrees C at 5 degrees C intervals using H3O+, NO+ and O2+* precursor ions, producing a mean Delta(vol)H/R value of 4700 +/- 200 K. This corresponds with current literature values and supports the consistency of the new method. Notably, using this method, as long as the concentration of the solution falls into the range of Henry's law, the exact concentration does not have to be known and it can require only one sample at each temperature. Compared with previous methods which involve the measurement of Henry's law constant at each temperature, this method significantly reduces the number of samples required and avoids the labour and difficulties in preparing standard solutions at very low concentrations. Further to this, if the contents of a solution were unknown the measured Delta(vol)H/R from individual product ion(s) can help to identify the origin of the ion(s). Copyright 2006 John Wiley & Sons, Ltd.
Webb, Ian K.; Gao, Yang; Londry, Frank A.; McLuckey, Scott A.
2013-01-01
The application of dipolar DC (DDC) to the RF-only ion guide (Q0) of a hybrid quadrupole/time-of-flight (QqTOF) mass spectrometer for collision-induced declustering of large bio-ions is described. As a broadband technique, ion trap DDC collision activation (CA) is employed to decluster ions simultaneously over a relatively broad mass-to-charge range. Declustering DDC CA can yield significantly narrower peaks relative to those observed in the absence of declustering methods, depending upon the extent of non-covalent adduction associated with the ions, and can also be used in conjunction with other methods, such as nozzle-skimmer collisional activation. The key experimental variables in the DDC experiment are the dipolar DC voltage (VDDC), VRF, and the time over which VDDC is applied. The VDDC/VRF ratio is key to the extent to which ion temperatures are elevated and also influences the upper mass-to-charge limit for ion storage. The VDDC/VRF ratio affects ion temperatures and upper m/z limit in opposing directions. That is, as the ratio increases, ion temperature increases whereas the upper m/z storage limit decreases. However, for a given VDDC/VRF ratio, the upper m/z storage limit can be increased by increasing VRF, at the expense of the lower m/z limit for ion storage. The key value of the approach is that it affords a relatively precise degree of control over ion temperatures as well as the time over which they are elevated to the higher temperature. The utility of the method is illustrated by the application of ion trap DDC CA in Q0 to oligonucleotide, protein, and multimeric protein complex analyte ions. PMID:24078247
Rakesh Minocha; Walter C. Shortle; Stephanie L. Long; Subhash C. Minocha
1994-01-01
A fast and reliable method for the extraction of cellular polyamines and major inorganic ions (Ca, Mg, Mn, K, and P) from several plant tissues is described. The method involves repeated freezing and thawing of samples instead of homogenization. The efficiency of extraction of both the polyamines and inorganic ions by these two methods was compared for 10 different...
High voltage and high specific capacity dual intercalating electrode Li-ion batteries
NASA Technical Reports Server (NTRS)
Blanco, Mario (Inventor); West, William C. (Inventor)
2010-01-01
The present invention provides high capacity and high voltage Li-ion batteries that have a carbonaceous cathode and a nonaqueous electrolyte solution comprising LiF salt and an anion receptor that binds the fluoride ion. The batteries can comprise dual intercalating electrode Li ion batteries. Methods of the present invention use a cathode and electrode pair, wherein each of the electrodes reversibly intercalate ions provided by a LiF salt to make a high voltage and high specific capacity dual intercalating electrode Li-ion battery. The present methods and systems provide high-capacity batteries particularly useful in powering devices where minimizing battery mass is important.
Messerli, Mark A.; Collis, Leon P.; Smith, Peter J.S.
2009-01-01
Previously, functional mapping of channels has been achieved by measuring the passage of net charge and of specific ions with electrophysiological and intracellular fluorescence imaging techniques. However, functional mapping of ion channels using extracellular ion-selective microelectrodes has distinct advantages over the former methods. We have developed this method through measurement of extracellular K+ gradients caused by efflux through Ca2+-activated K+ channels expressed in Chinese hamster ovary cells. We report that electrodes constructed with short columns of a mechanically stable K+-selective liquid membrane respond quickly and measure changes in local [K+] consistent with a diffusion model. When used in close proximity to the plasma membrane (<4 μm), the ISMs pose a barrier to simple diffusion, creating an ion trap. The ion trap amplifies the local change in [K+] without dramatically changing the rise or fall time of the [K+] profile. Measurement of extracellular K+ gradients from activated rSlo channels shows that rapid events, 10–55 ms, can be characterized. This method provides a noninvasive means for functional mapping of channel location and density as well as for characterizing the properties of ion channels in the plasma membrane. PMID:19217875
Metal-assisted SIMS and cluster ion bombardment for ion yield enhancement
NASA Astrophysics Data System (ADS)
Heile, A.; Lipinsky, D.; Wehbe, N.; Delcorte, A.; Bertrand, P.; Felten, A.; Houssiau, L.; Pireaux, J.-J.; De Mondt, R.; Van Vaeck, L.; Arlinghaus, H. F.
2008-12-01
In addition to structural information, a detailed knowledge of the local chemical environment proves to be of ever greater importance, for example for the development of new types of materials as well as for specific modifications of surfaces and interfaces in multiple fields of materials science or various biomedical and chemical applications. But the ongoing miniaturization and therefore reduction of the amount of material available for analysis constitute a challenge to the detection limits of analytical methods. In the case of time-of-flight secondary ion mass spectrometry (TOF-SIMS), several methods of secondary ion yield enhancement have been proposed. This paper focuses on the investigation of the effects of two of these methods, metal-assisted SIMS and polyatomic primary ion bombardment. For this purpose, thicker layers of polystyrene (PS), both pristine and metallized with different amounts of gold, were analyzed using monoatomic (Ar +, Ga +, Xe +, Bi +) and polyatomic (SF 5+, Bi 3+, C 60+) primary ions. It was found that polyatomic ions generally induce a significant increase of the secondary ion yield. On the other hand, with gold deposition, a yield enhancement can only be detected for monoatomic ion bombardment.
NASA Astrophysics Data System (ADS)
Truszczynski, Olaf; Skibniewski, Franciszek; Dziuda, Lukasz; Gacek, Adam; Krej, Mariusz; Sobotnicki, Aleksander; Rajchel, Jan; Bylinka, Marek; Burek, Michal
The authors present a new system for examining the behaviour of the human body and cerebral circulation in conditions of ischemic hypoxia and orthostatic stress that can cause orthostatic hypotension. Ischemic hypoxia affects mainly pilots of highly manoeuvrable aircraft, where long-lasting G forces not seldom reach 6-8 +Gz and can exceed the gravitational acceleration by ten times or more. Additionally, pilots are subjected to orthostatic hypotension in which abnormally low blood pressure is caused by pressure adjustment disorder and decreased stroke volume when changing body position rapidly. For several decades, these effects have been deeply investigated using human centrifuges or lower body negative pressure (LBNP) chambers. The latter method involves significantly less financial resources to carry out experiments and training, whereas the effects exerted on pilots, and the results of the training can be comparable. A group of researchers from the Military Institute of Aviation Medicine, Warszawa, Poland, and the Institute of Medical Technology and Equipment ITAM, Zabrze, Poland, are developing the innovative ORTHO-LBNP device based on the cradle principle and the LBNP method. The system will be implemented in a modern programme for training cadets of the Polish Air Force Academy, Dęblin, Poland. Together with other equipment such as a high-G centrifuge, pressure chambers, flight and spatial disorientation simulators as well as gymnastic training equipment for pilots (GTEP), the ORTHO-LBNP apparatus will be an element of the selection system of candidates for aviation. It is expected that the experimental studies will result in developing new indicators providing an objective assessment, whether examined persons possess the traits necessary for performing tasks related to the job of a pilot. It is highly probable that those indicators can be incorporated into routine checks for pilots, which in turn, can lead to improving the safety of flight operations and to higher fighting efficiency in pilots.
NASA Astrophysics Data System (ADS)
Yi, Chen; Isaev, A. E.; Yuebing, Wang; Enyakov, A. M.; Teng, Fei; Matveev, A. N.
2011-01-01
A description is given of the COOMET project 473/RU-a/09: a pilot comparison of hydrophone calibrations at frequencies from 250 Hz to 200 kHz between Hangzhou Applied Acoustics Research Institute (HAARI, China)—pilot laboratory—and Russian National Research Institute for Physicotechnical and Radio Engineering Measurements (VNIIFTRI, Designated Institute of Russia of the CIPM MRA). Two standard hydrophones, B&K 8104 and TC 4033, were calibrated and compared to assess the current state of hydrophone calibration of HAARI (China) and Russia. Three different calibration methods were applied: a vibrating column method, a free-field reciprocity method and a comparison method. The standard facilities of each laboratory were used, and three different sound fields were applied: pressure field, free-field and reverberant field. The maximum deviation of the sensitivities of two hydrophones between the participants' results was 0.36 dB. Main text. To reach the main text of this paper, click on Final Report. The final report has been peer-reviewed and approved for publication by the CCAUV-KCWG.
Draft environmental assessment: Ocean Thermal Energy Conversion (OTEC) Pilot Plants
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sullivan, S.M.; Sands, M.D.; Donat, J.R.
This Environmental Assessment (EA) has been prepared, in accordance with the National Environmental Policy Act of 1969, for the deployment and operation of a commercial 40-Megawatt (MW) Ocean Thermal Energy Conversion (OTEC) Pilot Plant (hereafter called the Pilot Plant). A description of the proposed action is presented, and a generic environment typical of the candidate Pilot Plant siting regions is described. An assessment of the potential environmental impacts associated with the proposed action is given, and the risk of credible accidents and mitigating measures to reduce these risks are considered. The Federal and State plans and policies the proposed actionmore » will encompass are described. Alternatives to the proposed action are presented. Appendix A presents the navigation and environmental information contained in the US Coast Pilot for each of the candidate sites; Appendix B provides a brief description of the methods and calculations used in the EA. It is concluded that environmental disturbances associated with Pilot Plant activities could potentially cause significant environmental impacts; however, the magnitude of these potential impacts cannot presently be assessed, due to insufficient engineering and environmental information. A site- and design-specific OTEC Pilot Plant Environmental Impact Statement (EIS) is required to resolve the potentially significant environmental effects associated with Pilot Plant deployment and operation. (WHK)« less
Audiometric profile of civilian pilots according to noise exposure
Falcão, Taiana Pacheco; Luiz, Ronir Raggio; Schütz, Gabriel Eduardo; Mello, Márcia Gomide da Silva; Câmara, Volney de Magalhães
2014-01-01
OBJECTIVE To evaluate the audiometric profile of civilian pilots according to the noise exposure level. METHODS This observational cross-sectional study evaluated 3,130 male civilian pilots aged between 17 and 59 years. These pilots were subjected to audiometric examinations for obtaining or revalidating the functional capacity certificate in 2011. The degree of hearing loss was classified as normal, suspected noise-induced hearing loss, and no suspected hearing loss with other associated complications. Pure-tone air-conduction audiometry was performed using supra-aural headphones and acoustic stimulus of the pure-tone type, containing tone thresholds of frequencies between 250 Hz and 6,000 Hz. The independent variables were professional categories, length of service, hours of flight, and right or left ear. The dependent variable was pilots with suspected noise-induced hearing loss. The noise exposure level was considered low/medium or high, and the latter involved periods > 5,000 flight hours and > 10 years of flight service. RESULTS A total of 29.3% pilots had suspected noise-induced hearing loss, which was bilateral in 12.8% and predominant in the left ear (23.7%). The number of pilots with suspected hearing loss increased as the noise exposure level increased. CONCLUSIONS Hearing loss in civilian pilots may be associated with noise exposure during the period of service and hours of flight. PMID:25372170
Strengthening, Crack Arrest And Multiple Cracking In Brittle Materials Using Residual Stresses.
Green, David J.; Sglavo, Vincenzo M.; Tandon, Rajan
2003-02-11
Embodiments include a method for forming a glass which displays visible cracking prior to failure when subjected to predetermined stress level that is greater than a predetermined minimum stress level and less than a failure stress level. The method includes determining a critical flaw size in the glass and introducing a residual stress profile to the glass so that a plurality of visible cracks are formed prior to failure when the glass is subjected to a stress that is greater than the minimum stress level and lower than the critical stress. One method for forming the residual stress profile includes performing a first ion exchange so that a first plurality of ions of a first element in the glass are exchanged with a second plurality of ions of a second element that have a larger volume than the first ions. A second ion exchange is also performed so that a plurality of the second ions in the glass are exchanged back to ions of the first element.
Method for fabricating carbon/lithium-ion electrode for rechargeable lithium cell
NASA Technical Reports Server (NTRS)
Attia, Alan I. (Inventor); Halpert, Gerald (Inventor); Huang, Chen-Kuo (Inventor); Surampudi, Subbarao (Inventor)
1995-01-01
The method includes steps for forming a carbon electrode composed of graphitic carbon particles adhered by an ethylene propylene diene monomer binder. An effective binder composition is disclosed for achieving a carbon electrode capable of subsequent intercalation by lithium ions. The method also includes steps for reacting the carbon electrode with lithium ions to incorporate lithium ions into graphitic carbon particles of the electrode. An electrical current is repeatedly applied to the carbon electrode to initially cause a surface reaction between the lithium ions and to the carbon and subsequently cause intercalation of the lithium ions into crystalline layers of the graphitic carbon particles. With repeated application of the electrical current, intercalation is achieved to near a theoretical maximum. Two differing multi-stage intercalation processes are disclosed. In the first, a fixed current is reapplied. In the second, a high current is initially applied, followed by a single subsequent lower current stage. Resulting carbon/lithium-ion electrodes are well suited for use as an anode in a reversible, ambient temperature, lithium cell.
Experimental Methods for Trapping Ions Using Microfabricated Surface Ion Traps
Hong, Seokjun; Lee, Minjae; Kwon, Yeong-Dae; Cho, Dong-il "Dan"; Kim, Taehyun
2017-01-01
Ions trapped in a quadrupole Paul trap have been considered one of the strong physical candidates to implement quantum information processing. This is due to their long coherence time and their capability to manipulate and detect individual quantum bits (qubits). In more recent years, microfabricated surface ion traps have received more attention for large-scale integrated qubit platforms. This paper presents a microfabrication methodology for ion traps using micro-electro-mechanical system (MEMS) technology, including the fabrication method for a 14 µm-thick dielectric layer and metal overhang structures atop the dielectric layer. In addition, an experimental procedure for trapping ytterbium (Yb) ions of isotope 174 (174Yb+) using 369.5 nm, 399 nm, and 935 nm diode lasers is described. These methodologies and procedures involve many scientific and engineering disciplines, and this paper first presents the detailed experimental procedures. The methods discussed in this paper can easily be extended to the trapping of Yb ions of isotope 171 (171Yb+) and to the manipulation of qubits. PMID:28872137
Superstatistics analysis of the ion current distribution function: Met3PbCl influence study.
Miśkiewicz, Janusz; Trela, Zenon; Przestalski, Stanisław; Karcz, Waldemar
2010-09-01
A novel analysis of ion current time series is proposed. It is shown that higher (second, third and fourth) statistical moments of the ion current probability distribution function (PDF) can yield new information about ion channel properties. The method is illustrated on a two-state model where the PDF of the compound states are given by normal distributions. The proposed method was applied to the analysis of the SV cation channels of vacuolar membrane of Beta vulgaris and the influence of trimethyllead chloride (Met(3)PbCl) on the ion current probability distribution. Ion currents were measured by patch-clamp technique. It was shown that Met(3)PbCl influences the variance of the open-state ion current but does not alter the PDF of the closed-state ion current. Incorporation of higher statistical moments into the standard investigation of ion channel properties is proposed.
Lou, Xianwen; van Dongen, Joost L J; Meijer, E W
2010-07-01
A simple method was developed for the generation of cesium iodide (CsI) cluster ions up to m/z over 20,000 in matrix-assisted laser desorption/ionization mass spectrometry (MALDI MS). Calibration ions in both positive and negative ion modes can readily be generated from a single MALDI spot of CsI(3) with 2-[(2E)-3-(4-tert-butylphenyl)-2-methylprop-2-enylidene] malononitrile (DCTB) matrix. The major cluster ion series observed in the positive ion mode is [(CsI)(n)Cs](+), and in the negative ion mode is [(CsI)(n)I](-). In both cluster series, ions spread evenly every 259.81 units. The easy method described here for the production of CsI cluster ions should be useful for MALDI MS calibrations. Copyright 2010 American Society for Mass Spectrometry. Published by Elsevier Inc. All rights reserved.
Mineralization of the textile dye acid yellow 42 by solar photoelectro-Fenton in a lab-pilot plant.
Espinoza, Carolina; Romero, Julio; Villegas, Loreto; Cornejo-Ponce, Lorena; Salazar, Ricardo
2016-12-05
A complete mineralization of a textile dye widely used in the Chilean textile industry, acid yellow 42 (AY42), was studied. Degradation was carried out in an aqueous solution containing 100mgL(-1) of total organic carbon (TOC) of dye using the advanced solar photoelectro-Fenton (SPEF) process in a lab-scale pilot plant consisting of a filter press cell, which contains a boron doped diamond electrode and an air diffusion cathode (BDD/air-diffusion cell), coupled with a solar photoreactor for treat 8L of wastewater during 270min of electrolysis. The main results obtained during the degradation of the textile dye were that a complete transformation to CO2 depends directly on the applied current density, the concentration of Fe(2+) used as catalyst, and the solar radiation intensity. The elimination of AY42 and its organic intermediates was due to hydroxyl radicals formed at the anode surface from water oxidation and in the bulk from Fenton's reaction between electrogenerated H2O2 and added Fe(2+). The application of solar radiation in the process (SPEF) yield higher current efficiencies and lower energy consumptions than electro-Fenton (EF) and electro-oxidation with electrogenerated H2O2 (E OH2O2) by the additional production of hydroxyl radicals from the photolysis of Fe(III) hydrated species and the photodecomposition of Fe(III) complexes with organic intermediates. Moreover, some products and intermediates formed during mineralization of dye, such as inorganic ions, carboxylic acids and aromatic compounds were determined by photometric and chromatographic methods. An oxidation pathway is proposed for the complete conversion to CO2. Copyright © 2016 Elsevier B.V. All rights reserved.
A Flying Qualities Study of Longitudinal Long-Term Dynamics of Hypersonic Planes
NASA Technical Reports Server (NTRS)
Cox, Timothy H.; Sachs, G.; Knoll, A.; Stich, R.
1995-01-01
The NASA Dryden Flight Research Center and the Technical University of Munich are cooperating in a research program to assess the impact of unstable long-term dynamics on the flying qualities of planes in hypersonic flight. These flying qualities issues are being investigated with a dedicated flight simulator for hypersonic vehicles located at NASA Dryden. Several NASA research pilots have flown the simulator through well defined steady-level turns with varying phugoid and height mode instabilities. The data collected include Pilot ratings and comments, performance measurements, and Pilot workload measurements. The results presented in this paper include design guidelines for height and Phugoid mode instabilities, an evaluation of the tapping method used to measure pilot workload, a discussion of techniques developed by the pilots to control large instabilities, and a discussion of how flying qualities of unstable long-term dynamics influence control Power design requirements.
A flying qualities study of longitudinal long-term dynamics of hypersonic planes
NASA Technical Reports Server (NTRS)
Cox, T.; Sachs, G.; Knoll, A.; Stich, R.
1995-01-01
The NASA Dryden Flight Research Center and the Technical University of Munich are cooperating in a research program to assess the impact of unstable long-term dynamics on the flying qualities of planes in hypersonic flight. These flying qualities issues are being investigated with a dedicated flight simulator for hypersonic vehicles located at NASA Dryden. Several NASA research pilots have flown the simulator through well-defined steady-level turns with varying phugoid and height mode instabilities. Th data collected include pilot ratings and comments, performance measurements, and pilot workload measurements. The results presented in this paper include design guidelines for height and phugoid mode instabilities, an evaluation of the tapping method used to measure pilot workload, a discussion of techniques developed by the pilots to control large instabilities, and a discussion of how flying qualities of unstable long-term dynamics influence control power design requirements.
Sun, Jing; Cao, Ling; Feng, Youlong; Tan, Li
2014-11-01
The compounds with similar structure often have similar pharmacological activities. So it is a trend for illegal addition that new derivatives of effective drugs are synthesized to avoid the statutory test. This bring challenges to crack down on illegal addition behavior, however, modified derivatives usually have similar product ions, which allow for precursor ion scanning. In this work, precursor ion scanning mode of a triple quadrupole mass spectrometer was first applied to screen illegally added drugs in complex matrix such as Chinese traditional patent medicines and healthy foods. Phosphodiesterase-5 inhibitors were used as experimental examples. Through the analysis of the structure and mass spectrum characteristics of the compounds, phosphodiesterase-5 inhibitors were classified, and their common product ions were screened by full scan of product ions of typical compounds. Then high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) method with precursor ion scanning mode was established based on the optimization of MS parameters. The effect of mass parameters and the choice of fragment ions were also studied. The method was applied to determine actual samples and further refined. The results demonstrated that this method can meet the need of rapid screening of unknown derivatives of phosphodiesterase-5 inhibitors in complex matrix, and prevent unknown derivatives undetected. This method shows advantages in sensitivity, specificity and efficiency, and is worth to be further investigated.
Synthesis of ion-exchange resin for selective thorium and uranyl ions sorption
NASA Astrophysics Data System (ADS)
Konovalov, Konstantin; Sachkov, Victor
2017-11-01
In this work, the method of ion-exchange resin synthesis selective to radionuclides (uranium and thorium) is presented. The method includes synthesis of polymeric styrene-divinylbenzene macroporous matrix with size of 0.1-0.2 mm, and its subsequent transformation by nitration and then reduction by tin (II) chloride. For passivation of active primary amines partially oxidation by oxygen from air is used. Obtained ion-exchange resin has ratio of sorption sum U+Th to sorption sum of other total rare-earth elements as 1:1.88 at ratio of solid to liquid phase 1:200. The proposed method of ion-exchange resin synthesis is scaled-up for laboratory reactors with volume of 5 and 50 liters.
Computational modeling of ion transport through nanopores.
Modi, Niraj; Winterhalter, Mathias; Kleinekathöfer, Ulrich
2012-10-21
Nanoscale pores are ubiquitous in biological systems while artificial nanopores are being fabricated for an increasing number of applications. Biological pores are responsible for the transport of various ions and substrates between the different compartments of biological systems separated by membranes while artificial pores are aimed at emulating such transport properties. As an experimental method, electrophysiology has proven to be an important nano-analytical tool for the study of substrate transport through nanopores utilizing ion current measurements as a probe for the detection. Independent of the pore type, i.e., biological or synthetic, and objective of the study, i.e., to model cellular processes of ion transport or electrophysiological experiments, it has become increasingly important to understand the dynamics of ions in nanoscale confinements. To this end, numerical simulations have established themselves as an indispensable tool to decipher ion transport processes through biological as well as artificial nanopores. This article provides an overview of different theoretical and computational methods to study ion transport in general and to calculate ion conductance in particular. Potential new improvements in the existing methods and their applications are highlighted wherever applicable. Moreover, representative examples are given describing the ion transport through biological and synthetic nanopores as well as the high selectivity of ion channels. Special emphasis is placed on the usage of molecular dynamics simulations which already have demonstrated their potential to unravel ion transport properties at an atomic level.
Time-of-flight SIMS/MSRI reflectron mass analyzer and method
Smentkowski, Vincent S.; Gruen, Dieter M.; Krauss, Alan R.; Schultz, J. Albert; Holecek, John C.
1999-12-28
A method and apparatus for analyzing the surface characteristics of a sample by Secondary Ion Mass Spectroscopy (SIMS) and Mass Spectroscopy of Recoiled Ions (MSRI) is provided. The method includes detecting back scattered primary ions, low energy ejected species, and high energy ejected species by ion beam surface analysis techniques comprising positioning a ToF SIMS/MSRI mass analyzer at a predetermined angle .theta., where .theta. is the angle between the horizontal axis of the mass analyzer and the undeflected primary ion beam line, and applying a specific voltage to the back ring of the analyzer. Preferably, .theta. is less than or equal to about 120.degree. and, more preferably, equal to 74.degree.. For positive ion analysis, the extractor, lens, and front ring of the reflectron are set at negative high voltages (-HV). The back ring of the reflectron is set at greater than about +700V for MSRI measurements and between the range of about +15 V and about +50V for SIMS measurements. The method further comprises inverting the polarity of the potentials applied to the extractor, lens, front ring, and back ring to obtain negative ion SIMS and/or MSRI data.
NASA Astrophysics Data System (ADS)
di Renzo, John Carl, Jr.
Scope and method of study. The purpose of this study was to test a hypothesis about pilot and instructor pilot perceptions of how effectively pilots learn and use new technology, found in Technically Advanced Aircraft (TAA), given initial type of instrumentation training. New aviation technologies such as Glass Cockpits in technically advanced aircraft are complex and can be difficult to learn and use. The research questions focused on the type of initial instrumentation training to determine the differences among pilots trained using various types of instrumentation ranging from aircraft equipped with traditional analog instrumentation to aircraft equipped with glass cockpits. A convenience sample of Pilots in Training (PT) and Instructor Pilots (IP) was selected from a regional airline. The research design used a mixed methodology. Pilots in training completed a thirty-two question quantitative questionnaire and instructor pilots completed a five question qualitative questionnaire. Findings and conclusions. This investigation failed to disprove the null hypothesis. The type of instrumentation training has no significant effect on newly trained regional airline pilot perceived ability to adapt to advanced technology cockpits. Therefore, no evidence exists from this investigation to support the early introduction and training of TAA. While the results of this investigation were surprising, they are nonetheless, instructive. Even though it would seem that there would be a relationship between exposure to and use of technically advanced instrumentation, apparently there was no perceived relationship for this group of airline transport pilots. However, a point of interest is that these pilots were almost evenly divided in their opinion of whether or not their previous training had prepared them for transition to TAA. The majority also believed that the type of initial instrumentation training received does make a difference when transitioning to TAA. Pilots believed that TAA made them safer pilots, but were not convinced it made them better pilots. The results of this investigation raise many new questions and provide a number of ideas for future research projects.
NASA Astrophysics Data System (ADS)
Zhang, Chuanqing; Feng, Xiating; Zhou, Hui; Qiu, Shili; Wu, Wenping
2012-05-01
The headrace tunnels at the Jinping II Hydropower Station cross the Jinping Mountain with a maximum overburden depth of 2,525 m, where 80% of the strata along the tunnels consist of marble. A number of extremely intense rockbursts occurred during the excavation of the auxiliary tunnels and the drainage tunnel. In particular, a tunnel boring machine (TBM) was destroyed by an extremely intense rockburst in a 7.2-m-diameter drainage tunnel. Two of the four subsequent 12.4-m-diameter headrace tunnels will be excavated with larger size TBMs, where a high risk of extremely intense rockbursts exists. Herein, a top pilot tunnel preconditioning method is proposed to minimize this risk, in which a drilling and blasting method is first recommended for the top pilot tunnel excavation and support, and then the TBM excavation of the main tunnel is conducted. In order to evaluate the mechanical effectiveness of this method, numerical simulation analyses using the failure approaching index, energy release rate, and excess shear stress indices are carried out. Its construction feasibility is discussed as well. Moreover, a microseismic monitoring technique is used in the experimental tunnel section for the real-time monitoring of the microseismic activities of the rock mass in TBM excavation and for assessing the effect of the top pilot tunnel excavation in reducing the risk of rockbursts. This method is applied to two tunnel sections prone to extremely intense rockbursts and leads to a reduction in the risk of rockbursts in TBM excavation.
Method for increasing the dynamic range of mass spectrometers
Belov, Mikhail; Smith, Richard D.; Udseth, Harold R.
2004-09-07
A method for enhancing the dynamic range of a mass spectrometer by first passing a sample of ions through the mass spectrometer having a quadrupole ion filter, whereupon the intensities of the mass spectrum of the sample are measured. From the mass spectrum, ions within this sample are then identified for subsequent ejection. As further sampling introduces more ions into the mass spectrometer, the appropriate rf voltages are applied to a quadrupole ion filter, thereby selectively ejecting the undesired ions previously identified. In this manner, the desired ions may be collected for longer periods of time in an ion trap, thus allowing better collection and subsequent analysis of the desired ions. The ion trap used for accumulation may be the same ion trap used for mass analysis, in which case the mass analysis is performed directly, or it may be an intermediate trap. In the case where collection is an intermediate trap, the desired ions are accumulated in the intermediate trap, and then transferred to a separate mass analyzer. The present invention finds particular utility where the mass analysis is performed in an ion trap mass spectrometer or a Fourier transform ion cyclotron resonance mass spectrometer.
Comparison of monomode KTiOPO4 waveguide formed by C3+ ion implantation and Rb+ ion exchange
NASA Astrophysics Data System (ADS)
Cui, Xiao-Jun; Wang, Liang-Ling
2017-02-01
In this work, we report on the formation and characterization of monomode KTiOPO4 waveguide at 1539 nm by 6.0 MeV C3+ ion implantation with the dose of 2×1015 ions/cm2 and Rb+-K+ ion exchange, respectively. The relative intensity of light as a function of effective refractive index of TM modes at 633 nm and 1539 nm for KTiOPO4 waveguide formed by two different methods were compared with the prism coupling technique. The refractive index (nz) profile for the ion implanted waveguide was reconstructed by reflectivity calculation method, and one for the ion exchanged waveguide was by inverse Wentzel-Kramers-Brillouin. The nuclear energy loss versus penetration depth of the C3+ ions implantation into KTiOPO4 was simulated using the Stopping Range of Ions in Matter software. The Rutherford Backscattering Spectrometry spectrum of KTiOPO4 waveguide was analyzed after ions exchanged. The results showed that monomode waveguide at 1539 nm can be formed by ion implantation and Rb+ -K+ ion exchange, respectively.
Metal ion transport quantified by ICP-MS in intact cells
Figueroa, Julio A. Landero; Stiner, Cory A.; Radzyukevich, Tatiana L.; Heiny, Judith A.
2016-01-01
The use of ICP-MS to measure metal ion content in biological tissues offers a highly sensitive means to study metal-dependent physiological processes. Here we describe the application of ICP-MS to measure membrane transport of Rb and K ions by the Na,K-ATPase in mouse skeletal muscles and human red blood cells. The ICP-MS method provides greater precision and statistical power than possible with conventional tracer flux methods. The method is widely applicable to studies of other metal ion transporters and metal-dependent processes in a range of cell types and conditions. PMID:26838181
Metal ion transport quantified by ICP-MS in intact cells.
Figueroa, Julio A Landero; Stiner, Cory A; Radzyukevich, Tatiana L; Heiny, Judith A
2016-02-03
The use of ICP-MS to measure metal ion content in biological tissues offers a highly sensitive means to study metal-dependent physiological processes. Here we describe the application of ICP-MS to measure membrane transport of Rb and K ions by the Na,K-ATPase in mouse skeletal muscles and human red blood cells. The ICP-MS method provides greater precision and statistical power than possible with conventional tracer flux methods. The method is widely applicable to studies of other metal ion transporters and metal-dependent processes in a range of cell types and conditions.
Method of multiplexed analysis using ion mobility spectrometer
Belov, Mikhail E [Richland, WA; Smith, Richard D [Richland, WA
2009-06-02
A method for analyzing analytes from a sample introduced into a Spectrometer by generating a pseudo random sequence of a modulation bins, organizing each modulation bin as a series of submodulation bins, thereby forming an extended pseudo random sequence of submodulation bins, releasing the analytes in a series of analyte packets into a Spectrometer, thereby generating an unknown original ion signal vector, detecting the analytes at a detector, and characterizing the sample using the plurality of analyte signal subvectors. The method is advantageously applied to an Ion Mobility Spectrometer, and an Ion Mobility Spectrometer interfaced with a Time of Flight Mass Spectrometer.
In situ plasma removal of surface contaminants from ion trap electrodes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Haltli, Raymond A.
2015-05-01
In this thesis, the construction and implementation of an in situ plasma discharge designed to remove surface contaminants from electrodes in an ion trapping experimental system is presented with results. In recent years, many advances have been made in using ion traps for quantum information processing. All of the criteria defined by DiVincenzo for using ion traps for implementing a quantum computer have been individually demonstrated, and in particular surface traps provide a scalable platform for ions. In order to be used for quantum algorithms, trapped ions need to be cooled to their motional (quantum mechanical) ground state. One ofmore » the hurdles in integrating surface ion traps for a quantum computer is minimizing electric field noise, which causes the ion to heat out of its motional ground state and which increases with smaller ion-to-electrode distances realized with surface traps. Surface contamination of trap electrodes is speculated to be the primary source of electric field noise. The main goal achieved by this work was to implement an in situ surface cleaning solution for surface electrode ion traps, which would not modify the ion trap electrode surface metal. Care was taken in applying the RF power in order to localize a plasma near the trap electrodes. A method for characterizing the energy of the plasma ions arriving at the ion trap surface is presented and results for plasma ion energies are shown. Finally, a method for quantifying the effectiveness of plasma cleaning of trap electrodes, using the surface analysis technique of X-ray photoelectron spectroscopy for measuring the amount and kind of surface contaminants, is described. A significant advantage of the trap electrode surface cleaning method presented here is the minimal changes necessary for implementation on a working ion trap experimental system.« less
Kasahara, Kota; Kinoshita, Kengo
2016-01-01
Ion conduction mechanisms of ion channels are a long-standing conundrum. Although the molecular dynamics (MD) method has been extensively used to simulate ion conduction dynamics at the atomic level, analysis and interpretation of MD results are not straightforward due to complexity of the dynamics. In our previous reports, we proposed an analytical method called ion-binding state analysis to scrutinize and summarize ion conduction mechanisms by taking advantage of a variety of analytical protocols, e.g., the complex network analysis, sequence alignment, and hierarchical clustering. This approach effectively revealed the ion conduction mechanisms and their dependence on the conditions, i.e., ion concentration and membrane voltage. Here, we present an easy-to-use computational toolkit for ion-binding state analysis, called IBiSA_tools. This toolkit consists of a C++ program and a series of Python and R scripts. From the trajectory file of MD simulations and a structure file, users can generate several images and statistics of ion conduction processes. A complex network named ion-binding state graph is generated in a standard graph format (graph modeling language; GML), which can be visualized by standard network analyzers such as Cytoscape. As a tutorial, a trajectory of a 50 ns MD simulation of the Kv1.2 channel is also distributed with the toolkit. Users can trace the entire process of ion-binding state analysis step by step. The novel method for analysis of ion conduction mechanisms of ion channels can be easily used by means of IBiSA_tools. This software is distributed under an open source license at the following URL: http://www.ritsumei.ac.jp/~ktkshr/ibisa_tools/.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Slabodchikov, Vladimir A., E-mail: dipis1991@mail.ru; Borisov, Dmitry P., E-mail: borengin@mail.ru; Kuznetsov, Vladimir M., E-mail: kuznetsov@rec.tsu.ru
The paper reports on a new method of plasma immersion ion implantation for the surface modification of medical materials using the example of nickel-titanium (NiTi) alloys much used for manufacturing medical implants. The chemical composition and surface properties of NiTi alloys doped with silicon by conventional ion implantation and by the proposed plasma immersion method are compared. It is shown that the new plasma immersion method is more efficient than conventional ion beam treatment and provides Si implantation into NiTi surface layers through a depth of a hundred nanometers at low bias voltages (400 V) and temperatures (≤150°C) of the substrate.more » The research results suggest that the chemical composition and surface properties of materials required for medicine, e.g., NiTi alloys, can be successfully attained through modification by the proposed method of plasma immersion ion implantation and by other methods based on the proposed vacuum equipment without using any conventional ion beam treatment.« less
Shirai, Katsuyuki; Kawashima, Motohiro; Saitoh, Jun-Ichi; Abe, Takanori; Fukata, Kyohei; Shigeta, Yuka; Irie, Daisuke; Shiba, Shintaro; Okano, Naoko; Ohno, Tatsuya; Nakano, Takashi
2017-01-01
The safety and efficacy of carbon-ion radiotherapy for advanced non-small cell lung cancer have not been established. We evaluated the clinical outcomes and dose-volume histogram parameters of carbon-ion radiotherapy compared with photon therapy in T2b-4N0M0 non-small cell lung cancer. Twenty-three patients were treated with carbon-ion radiotherapy between May 2011 and December 2015. Seven, 14, and 2 patients had T2b, T3, and T4, respectively. The median age was 78 (range, 53-91) years, with 22 male patients. There were 12 adenocarcinomas, 8 squamous cell carcinomas, 1 non-small cell lung carcinoma, and 2 clinically diagnosed lung cancers. Eleven patients were operable, and 12 patients were inoperable. Most patients (91%) were treated with carbon-ion radiotherapy of 60.0 Gy relative biological effectiveness (RBE) in 4 fractions or 64.0 Gy (RBE) in 16 fractions. Local control and overall survival rates were calculated. Dose-volume histogram parameters of normal lung and tumor coverages were compared between carbon-ion radiotherapy and photon therapies, including three-dimensional conformal radiotherapy (3DCRT) and intensity-modulated radiotherapy (IMRT). The median follow-up of surviving patients was 25 months. Three patients experienced local recurrence, and the 2-year local control rate was 81%. During follow-up, 5 patients died of lung cancer, and 1 died of intercurrent disease. The 2-year overall survival rate was 70%. Operable patients had a better overall survival rate compared with inoperable patients (100% vs. 43%; P = 0.04). There was no grade ≥2 radiation pneumonitis. In dose-volume histogram analysis, carbon-ion radiotherapy had a significantly lower dose to normal lung and greater tumor coverage compared with photon therapies. Carbon-ion radiotherapy was effectively and safely performed for T2b-4N0M0 non-small cell lung cancer, and the dose distribution was superior compared with those for photon therapies. A Japanese multi-institutional study is ongoing to prospectively evaluate these patients and establish the use of carbon-ion radiotherapy.
Stacciarini, Jeanne-Marie R; Smith, Rebekah; Garvan, Cynthia Wilson; Wiens, Brenda; Cottler, Linda B
2015-05-01
Upon immigration to the rural areas in the US, Latino families may experience cultural, geographic, linguistic and social isolation, which can detrimentally affect their wellbeing by acting as chronic stressors. Using a community engagement approach, this is a pilot mixed-method study with an embedded design using concurrent qualitative and quantitative data. The purpose of this study is to evaluate family and social environments in terms of protective factors and modifiable risks associated with mental well-being in Latino immigrants living in rural areas of Florida. Latino immigrant mother and adolescent dyads were interviewed by using in-depth ethnographic semistructured interviews and subsequent quantitative assessments, including a demographic questionnaire and three structured instruments: the Family Environment Scale Real Form, the SF-12v2™ Health Survey and the short version (eight items) of PROMIS Health Organization Social Isolation. This mixed-method pilot study highlighted how family, rural, and social environments can protect or impair wellbeing in rural Latino immigrant mother and adolescent dyads.
ERIC Educational Resources Information Center
Sheeber, Lisa B.; Seeley, John R.; Feil, Edward G.; Davis, Betsy; Sorensen, Erik; Kosty, Derek B.; Lewinsohn, Peter M.
2012-01-01
Objective: Develop and pilot an Internet-facilitated cognitive-behavioral treatment intervention for depression, tailored to economically disadvantaged mothers of young children. Method: Mothers (N = 70) of children enrolled in Head Start, who reported elevated levels of depressive symptoms, were randomized to either the 8-session,…
ERIC Educational Resources Information Center
Chung, Henry; Klein, Michael C.; Silverman, Daniel; Corson-Rikert, Janet; Davidson, Eleanor; Ellis, Patricia; Kasnakian, Caroline
2011-01-01
Objective: To implement a pilot quality improvement project for depression identification and treatment in college health. Participants: Eight college health center teams composed primarily of primary care and counseling service directors and clinicians. Methods: Chronic (Collaborative) Care Model (CCM) used with standardized screening to…
Research Note-Testing for Gerontological Competencies: A Pilot Study
ERIC Educational Resources Information Center
Galambos, Colleen; Curl, Angela L.; Woodbury, Karen
2014-01-01
This article reports on the pilot delivery of an evaluation method to gauge student learning of gerontological competencies. Using a pretest and posttest design, data were collected on 46 students over 3 classes. Results indicated significant improvement in how students rated or perceived their competencies skill level between pretest and posttest…
EPA Region 10 Climate Change and TMDL Pilot – South Fork Nooksack River, Washington Final Report
This final report provides an overarching summary of the pilot research project, including the methods used in and the findings of the quantitative and qualitative assessments. It is written to appeal to a wide audience of policy makers, managers, agency staff and the general pub...
Pilot Evaluation of a Home Visit Parent Training Program in Disadvantaged Families
ERIC Educational Resources Information Center
Leung, Cynthia; Tsang, Sandra; Heung, Kitty
2013-01-01
Objectives: The study reported the pilot evaluation of the Healthy Start Home Visit Program for disadvantaged Chinese parents with preschool children, delivered by trained parent assistants. Home visiting was used to make services more accessible to disadvantaged families. Method: The participants included 21 parent-child dyads. Outcome measures…
A PILOT CENTER FOR EDUCATIONAL POLICY RESEARCH. FINAL REPORT--PART I.
ERIC Educational Resources Information Center
ADELSON, MARVIN; AND OTHERS
THE PILOT CENTER FOR EDUCATIONAL POLICY RESEARCH, OPERATED BY THE SYSTEM DEVELOPMENT CORPORATION FROM JUNE 1, 1967, THROUGH FEBRUARY 29, 1968, HAD THREE OBJECTIVES--(1) TO INVESTIGATE, ANALYZE, AND EXPERIMENT WITH METHODS, PROCEDURES, AND TOOLS FOR STUDYING THE FUTURE AS IT COULD AFFECT EDUCATION IN THE UNITED STATES, (2) TO FORECAST POSSIBLE…
The product is a presentation requested by the organizers of the 2005 US EPA Bioavailability Technical Review Workgroup. It presents an overview, approaches (in-vivo & in-vitro), and logistics of the ORD pilot study on bioavailability of arsenic in soil. The overall project was ...
GRAPHEME-PHONEME REGULARITY AND ITS EFFECTS ON EARLY READING--A PILOT STUDY.
ERIC Educational Resources Information Center
FRANKENSTEIN, ROSELYN; KJELDERGAARD, PAUL M.
A PILOT EXPERIMENT CONDUCTED TO TEST THE EFFECT OF A SPECIALLY DEVISED PHONIC APPROACH TO EARLY READING IS DESCRIBED. THE PHONIC METHOD USED ACHIEVED SOUND-SYMBOL REGULARITY AND HAD THE FOLLOWING CHARACTERISTICS--(1) CONSONANT GRAPHEMES EACH REPRESENTED ONLY ONE SOUND AND WERE PRINTED USING NEARLY STANDARD ALPHABETIC SYMBOLS. (2) EACH VOWEL…
In-Service Training Argumentation Application for Elementary School Teachers: Pilot Study
ERIC Educational Resources Information Center
Alkis-Küçükaydin, Mensure; Uluçinar Sagir, Safak; Kösterelioglu, Ilker
2016-01-01
Science Course Curriculum was revised in Turkey in 2013 and some methods and strategies were suggested to be included such as argumentation. This study includes the evaluation of in-service training applied as pilot study for introducing argumentation to elementary school teachers. The study consists of applying needs analysis, preparing and…
EEG Neurofeedback for ADHD: Double-Blind Sham-Controlled Randomized Pilot Feasibility Trial
ERIC Educational Resources Information Center
Arnold, L. Eugene; Lofthouse, Nicholas; Hersch, Sarah; Pan, Xueliang; Hurt, Elizabeth; Bates, Bethany; Kassouf, Kathleen; Moone, Stacey; Grantier, Cara
2013-01-01
Objective: Preparing for a definitive randomized clinical trial (RCT) of neurofeedback (NF) for ADHD, this pilot trial explored feasibility of a double-blind, sham-controlled design and adherence/palatability/relative effect of two versus three treatments/week. Method: Unmedicated 6- to 12-year-olds with "Diagnostic and Statistical Manual of…
Physical activity in Georgia state parks: A pilot study
Lincoln R. Larson; Jason W. Whiting; Gary T. Green
2012-01-01
This pilot study assessed the role of Georgia State Parks in the promotion of physical activity among different racial/ethnic and age groups. Data were collected at three state parks in north Georgia during the summer of 2009 using two research methods: behavior observations (N=2281) and intercept surveys (N=473).
Skill Development for Maneuvering on the Information Highway.
ERIC Educational Resources Information Center
Mosley, Barbra; Edwards, Gloria
To help students learn to navigate the information superhighway, a 2-hour pilot program with 10 hours of guided access time was developed to test a method for teaching the basics of maneuvering the superhighway and extracting information once located. This pilot was designed as a two-part instructional session. The first instructional session…
Teaching Health Literacy Using Popular Television Programming: A Qualitative Pilot Study
ERIC Educational Resources Information Center
Primack, Brian A.; Wickett, Dustin J.; Kraemer, Kevin L.; Zickmund, Susan
2010-01-01
Background: Teaching of health and medical concepts in the K-12 curriculum may help improve health literacy. Purpose: The purpose of this project was to determine acceptability and preliminary efficacy of pilot implementation of a health literacy curriculum using brief clips from a popular television program. Methods: Participants included 55…
A Mindfulness-Based Group for Young People with Learning Disabilities: A Pilot Study
ERIC Educational Resources Information Center
Thornton, Victoria; Williamson, Rachel; Cooke, Bronwen
2017-01-01
Background: Mindfulness is becoming increasingly reported as an effective way to support well-being and reduce mental health difficulties. Materials and Methods: This study reports on the development and pilot of a mindfulness-based group for young people with learning disabilities and their carers. Results: Group participants reported that the…
Improving Understanding about Tanning Behaviors in College Students: A Pilot Study
ERIC Educational Resources Information Center
Basch, Corey Hannah; Hillyer, Grace Clarke; Basch, Charles E.; Neugut, Alfred I.
2012-01-01
Objective: Melanoma is the second most common cancer diagnosed among 15- to 29-year-olds. This pilot study assessed behaviors, barriers, and beliefs relevant to sun exposure and protective behaviors. Participants: The sample comprised 153 undergraduate students at a large state university in western New York. Methods: Participants completed an…
Detention Home Teens as Tutors: A Cooperative Cross-Age Tutoring Pilot Project
ERIC Educational Resources Information Center
Lazerson, David B.
2005-01-01
Concerned professionals in the juvenile justice field frequently express concern for effective programs that help youth offenders successfully rejoin society. This mixed-method pilot study involved detention home teens functioning as tutors for special education students in a public school. Tutors were selected who, based on previous assessment as…
Developing and Piloting a Form for Student Assessment of Faculty Professionalism
ERIC Educational Resources Information Center
Todhunter, Sarah; Cruess, Sylvia R.; Cruess, Richard L.; Young, Meredith; Steinert, Yvonne
2011-01-01
One of the impediments to teaching professionalism is unprofessional behavior amongst clinical teachers. No method of reliably assessing the professional behavior of clinical teachers has yet been reported. The aim of this project was to develop and pilot such a tool. Thirty-four desirable professional behaviors in clinical teachers were…
Lecturer Perspectives on Dyslexia within One Greek University: A Pilot Study
ERIC Educational Resources Information Center
Stampoltzis, Aglaia; Tsitsou, Elisavet; Plesti, Helen; Kalouri, Rani
2015-01-01
Introduction: Dyslexia is a learning difficulty which affects people in different ways. During the last decades the number of students with dyslexia entering higher education increased steadily. Method: This paper reports a pilot study exploring the attitudes, views and experiences of faculty members at one small size Greek university regarding…
Not-from-concentrate pilot plant ‘Wonderful’ cultivar pomegranate juice changes: Volatiles
USDA-ARS?s Scientific Manuscript database
Pilot plant ultrafiltration was used to mimic the dominant U.S. commercial pomegranate juice extraction method (hydraulic pressing whole fruit), to deliver a not-from-concentrate (NFC) juice that was high-temperature short-time pasteurized and stored at 4 and 25 °C. Recovered were 46 compounds, of ...
Pasteurization of strawberry puree using a pilot plant pulsed electric fields (PEF) system
USDA-ARS?s Scientific Manuscript database
The processing of strawberry puree by pulsed electric fields (PEF) in a pilot plant system has never been evaluated. In addition, a method does not exist to validate the exact number and shape of the pulses applied during PEF processing. Both buffered peptone water (BPW) and fresh strawberry puree (...
Definition of Alaskan Aviation Training Requirements. Final Report.
ERIC Educational Resources Information Center
Mitchell, M. K.; And Others
Because of high accident rates and the unique conditions faced in Arctic flying, a project was conducted to develop a training program for airline pilots flying over Alaska. Data were gathered, through the critical incident method in conjunction with traditional job-analysis procedures, about how experienced Alaskan pilots learned to cope with the…
Reversible photodeposition and dissolution of metal ions
Foster, Nancy S.; Koval, Carl A.; Noble, Richard D.
1994-01-01
A cyclic photocatalytic process for treating waste water containing metal and organic contaminants. In one embodiment of the method, metal ions are photoreduced onto the photocatalyst and the metal concentrated by resolubilization in a smaller volume. In another embodiment of the method, contaminant organics are first oxidized, then metal ions removed by photoreductive deposition. The present invention allows the photocatalyst to be recycled until nearly complete removal of metal ions and organic contaminants is achieved.
Improvements in hover display dynamics for a combat helicopter
NASA Technical Reports Server (NTRS)
Eshow, Michelle M.; Schroeder, Jeffery A.
1993-01-01
This paper describes a piloted simulation conducted on the NASA Ames Vertical Motion Simulator. The objective of the experiment was to investigate the handling qualities benefits attainable using new display law design methods for hover displays. The new display laws provide improved methods to specify the behavior of the display symbol that predicts the vehicle's ground velocity in the horizontal plane; it is the primary symbol that the pilot uses to control aircraft horizontal position. The display law design was applied to the Apache helmet-mounted display format, using the Apache vehicle dynamics to tailor the dynamics of the velocity predictor symbol. The representations of the Apache vehicle used in the display design process and in the simulation were derived from flight data. During the simulation, the new symbol dynamics were seen to improve the pilots' ability to maneuver about hover in poor visual cuing environments. The improvements were manifested in pilot handling qualities ratings and in measured task performance. The paper details the display design techniques, the experiment design and conduct, and the results.
Multiple products monitoring as a robust approach for peptide quantification.
Baek, Je-Hyun; Kim, Hokeun; Shin, Byunghee; Yu, Myeong-Hee
2009-07-01
Quantification of target peptides and proteins is crucial for biomarker discovery. Approaches such as selected reaction monitoring (SRM) and multiple reaction monitoring (MRM) rely on liquid chromatography and mass spectrometric analysis of defined peptide product ions. These methods are not very widespread because the determination of quantifiable product ion using either SRM or MRM is a very time-consuming process. We developed a novel approach for quantifying target peptides without such an arduous process of ion selection. This method is based on monitoring multiple product ions (multiple products monitoring: MpM) from full-range MS2 spectra of a target precursor. The MpM method uses a scoring system that considers both the absolute intensities of product ions and the similarities between the query MS2 spectrum and the reference MS2 spectrum of the target peptide. Compared with conventional approaches, MpM greatly improves sensitivity and selectivity of peptide quantification using an ion-trap mass spectrometer.
Neutron interrogation systems using pyroelectric crystals and methods of preparation thereof
Tang, Vincent; Meyer, Glenn A.; Falabella, Steven; Guethlein, Gary; Rusnak, Brian; Sampayan, Stephen; Spadaccini, Christopher M.; Wang, Li-Fang; Harris, John; Morse, Jeff
2017-08-01
According to one embodiment, an apparatus includes a pyroelectric crystal, a deuterated or tritiated target, an ion source, and a common support coupled to the pyroelectric crystal, the deuterated or tritiated target, and the ion source. In another embodiment, a method includes producing a voltage of negative polarity on a surface of a deuterated or tritiated target in response to a temperature change of a pyroelectric crystal, pulsing a deuterium ion source to produce a deuterium ion beam, accelerating the deuterium ion beam to the deuterated or tritiated target to produce a neutron beam, and directing the ion beam onto the deuterated or tritiated target to make neutrons using a voltage of the pyroelectric crystal and/or an HGI surrounding the pyroelectric crystal. The directionality of the neutron beam is controlled by changing the accelerating voltage of the system. Other apparatuses and methods are presented as well.
Trapped-Ion Quantum Logic with Global Radiation Fields.
Weidt, S; Randall, J; Webster, S C; Lake, K; Webb, A E; Cohen, I; Navickas, T; Lekitsch, B; Retzker, A; Hensinger, W K
2016-11-25
Trapped ions are a promising tool for building a large-scale quantum computer. However, the number of required radiation fields for the realization of quantum gates in any proposed ion-based architecture scales with the number of ions within the quantum computer, posing a major obstacle when imagining a device with millions of ions. Here, we present a fundamentally different approach for trapped-ion quantum computing where this detrimental scaling vanishes. The method is based on individually controlled voltages applied to each logic gate location to facilitate the actual gate operation analogous to a traditional transistor architecture within a classical computer processor. To demonstrate the key principle of this approach we implement a versatile quantum gate method based on long-wavelength radiation and use this method to generate a maximally entangled state of two quantum engineered clock qubits with fidelity 0.985(12). This quantum gate also constitutes a simple-to-implement tool for quantum metrology, sensing, and simulation.
Maya, L.
1981-11-05
A reactive ion exchange method for separation and recovery of values of uranium, neptunium, plutonium, or americium from substantially neutral aqueous systems of said metals comprises contacting said system with an effective amount of a basic anion exchange resin of copolymerized divinyl-benzene and styrene having quarternary ammonium groups and bicarbonate ligands to achieve nearly 100% sorption of said actinyl ion onto said resin and an aqueous system practically free of said actinyl ions. The method is operational over an extensive range of concentrations from about 10/sup -6/ M to 1.0 M actinyl ion and a pH range of about 4 to 7. The method has particulr application to treatment of waste streams from Purex-type nuclear fuel reprocessing facilities and hydrometallurgical processes involving U, Np, P, or Am.
Strategies for generating peptide radical cations via ion/ion reactions.
Gilbert, Joshua D; Fisher, Christine M; Bu, Jiexun; Prentice, Boone M; Redwine, James G; McLuckey, Scott A
2015-02-01
Several approaches for the generation of peptide radical cations using ion/ion reactions coupled with either collision induced dissociation (CID) or ultraviolet photo dissociation (UVPD) are described here. Ion/ion reactions are used to generate electrostatic or covalent complexes comprised of a peptide and a radical reagent. The radical site of the reagent can be generated multiple ways. Reagents containing a carbon-iodine (C-I) bond are subjected to UVPD with 266-nm photons, which selectively cleaves the C-I bond homolytically. Alternatively, reagents containing azo functionalities are collisionally activated to yield radical sites on either side of the azo group. Both of these methods generate an initial radical site on the reagent, which then abstracts a hydrogen from the peptide while the peptide and reagent are held together by either electrostatic interactions or a covalent linkage. These methods are demonstrated via ion/ion reactions between the model peptide RARARAA (doubly protonated) and various distonic anionic radical reagents. The radical site abstracts a hydrogen atom from the peptide, while the charge site abstracts a proton. The net result is the conversion of a doubly protonated peptide to a peptide radical cation. The peptide radical cations have been fragmented via CID and the resulting product ion mass spectra are compared to the control CID spectrum of the singly protonated, even-electron species. This work is then extended to bradykinin, a more broadly studied peptide, for comparison with other radical peptide generation methods. The work presented here provides novel methods for generating peptide radical cations in the gas phase through ion/ion reaction complexes that do not require modification of the peptide in solution or generation of non-covalent complexes in the electrospray process. Copyright © 2015 John Wiley & Sons, Ltd.
NASA Astrophysics Data System (ADS)
Rasmagin, S. I.; Krasovskii, V. I.; Apresyan, L. A.; Novikov, I. K.; Krystob, V. I.; Kazaryan, M. A.
2018-04-01
By the method of green synthesis, silver nanoparticles were obtained in colloidal solutions. The solutions were modified with thulium ions. Using the method of electron microscopy and optical method, the properties of silver nanoparticles obtained are studied. The influence of change in concentration of the solution of mint and thulium ions on the properties of colloidal silver nanoparticles was studied.
Large-scale collision cross-section profiling on a travelling wave ion mobility mass spectrometer
Lietz, Christopher B.; Yu, Qing; Li, Lingjun
2014-01-01
Ion mobility (IM) is a gas-phase electrophoretic method that separates ions according to charge and ion-neutral collision cross-section (CCS). Herein, we attempt to apply a travelling wave (TW) IM polyalanine calibration method to shotgun proteomics and create a large peptide CCS database. Mass spectrometry methods that utilize IM, such as HDMSE, often use high transmission voltages for sensitive analysis. However, polyalanine calibration has only been demonstrated with low voltage transmission used to prevent gas-phase activation. If polyalanine ions change conformation under higher transmission voltages used for HDMSE, the calibration may no longer be valid. Thus, we aimed to characterize the accuracy of calibration and CCS measurement under high transmission voltages on a TW IM instrument using the polyalanine calibration method and found that the additional error was not significant. We also evaluated the potential error introduced by liquid chromatography (LC)-HDMSE analysis, and found it to be insignificant as well, validating the calibration method. Finally, we demonstrated the utility of building a large-population peptide CCS database by investigating the effects of terminal lysine position, via LysC or LysN digestion, on the formation of two structural sub-families formed by triply charged ions. PMID:24845359
Method for preparation and readout of polyatomic molecules in single quantum states
NASA Astrophysics Data System (ADS)
Patterson, David
2018-03-01
Polyatomic molecular ions contain many desirable attributes of a useful quantum system, including rich internal degrees of freedom and highly controllable coupling to the environment. To date, the vast majority of state-specific experimental work on molecular ions has concentrated on diatomic species. The ability to prepare and read out polyatomic molecules in single quantum states would enable diverse experimental avenues not available with diatomics, including new applications in precision measurement, sensitive chemical and chiral analysis at the single-molecule level, and precise studies of Hz-level molecular tunneling dynamics. While cooling the motional state of a polyatomic ion via sympathetic cooling with a laser-cooled atomic ion is straightforward, coupling this motional state to the internal state of the molecule has proven challenging. Here we propose a method for readout and projective measurement of the internal state of a trapped polyatomic ion. The method exploits the rich manifold of technically accessible rotational states in the molecule to realize robust state preparation and readout with far less stringent engineering than quantum logic methods recently demonstrated on diatomic molecules. The method can be applied to any reasonably small (≲10 atoms) polyatomic ion with an anisotropic polarizability.
Ruiz-Samblás, C; González-Casado, A; Cuadros-Rodríguez, L; García, F P Rodríguez
2010-06-30
The analysis of the triacylglycerol (TAG) composition of oils is a very challenging task, since the TAGs have very similar physico-chemical properties. In this work, a high temperature-gas chromatographic method coupled to electron ionization-mass spectrometry (HT-GC/EI-MS), in the Selected Ion Monitoring (SIM) mode, method was developed for the analysis of TAGs in the olive oil; this is a method suitable for routine analysis. This method was developed using commercially available standard TAGs. The TAGs studied were separated according to their equivalent carbon number and degree of unsaturation. The peak assignment was carried out by locating the characteristic fragment ions having the same retention time on the SIM profile such as [RCO+74](+) and [RCO+128](+) ions, due to the fatty acyl residues on sn-1, sn-2 and sn-3 positions of the TAG molecule and the [M-OCOR](+) ions corresponding to the acyl ions. The developed method was very useful to eliminate the interferences that appeared in the mass spectrum since electron ionization can prevent satisfactory interpretation of spectra. Copyright 2010 Elsevier B.V. All rights reserved.
Webb, Ian K; Londry, Frank A; McLuckey, Scott A
2011-09-15
Means for effecting dipolar direct current collision-induced dissociation (DDC CID) on a quadrupole/time-of-flight in a mass spectrometer have been implemented for the broadband dissociation of a wide range of analyte ions. The DDC fragmentation method in electrodynamic storage and transmission devices provides a means for inducing fragmentation of ions over a large mass-to-charge range simultaneously. It can be effected within an ion storage step in a quadrupole collision cell that is operated as a linear ion trap or as ions are continuously transmitted through the collision cell. A DDC potential is applied across one pair of rods in the quadrupole collision cell of a QqTOF hybrid mass spectrometer to effect fragmentation. In this study, ions derived from a small drug molecule, a model peptide, a small protein, and an oligonucleotide were subjected to the DDC CID method in either an ion trapping or an ion transmission mode (or both). Several key experimental parameters that affect DDC CID results, such as time, voltage, low mass cutoff, and bath gas pressure, are illustrated with protonated leucine enkephalin. The DDC CID dissociation method gives a readily tunable, broadband tool for probing the primary structures of a wide range of analyte ions. The method provides an alternative to the narrow resonance conditions of conventional ion trap CID and it can access more extensive sequential fragmentation, depending upon conditions. The DDC CID approach constitutes a collision analog to infrared multiphoton dissociation (IRMPD). Copyright © 2011 John Wiley & Sons, Ltd.
Transport of ions using RF Carpets in Helium Gas
NASA Astrophysics Data System (ADS)
Lambert, Keenan; Kelly, James; Brodeur, Maxime
2017-09-01
Radio-Frequency (RF) carpet are critical components of large volume gas cells used to thermalize radioactive ion beams produced at in-flight facilities. RF carpets are formed by a series of co-centric conductive rings on which an alternating potential (in the radio-frequency range) is applied with opposite polarity on adjacent rings. This results in a strong repelling force that keep the ions a certain distance from the carpet. The transport of ions using RF carpet is accomplished using either a potential gradient applied on the individual all strips or traveling wave (using the so-called `ion surfing method'). A test setup has been constructed at the University of Notre Dame to perform studies on the repelling of ions using RF carpets. This test setup has recently been improved by the addiction of circuitry elements allowing the transport of ions using the ion surfing method. The developed circuitry, together with transport results for various ion beam currents, electric force applied on the ions, and traveling wave amplitude and speed will be presented
A modified homotopy perturbation method and the axial secular frequencies of a non-linear ion trap.
Doroudi, Alireza
2012-01-01
In this paper, a modified version of the homotopy perturbation method, which has been applied to non-linear oscillations by V. Marinca, is used for calculation of axial secular frequencies of a non-linear ion trap with hexapole and octopole superpositions. The axial equation of ion motion in a rapidly oscillating field of an ion trap can be transformed to a Duffing-like equation. With only octopole superposition the resulted non-linear equation is symmetric; however, in the presence of hexapole and octopole superpositions, it is asymmetric. This modified homotopy perturbation method is used for solving the resulting non-linear equations. As a result, the ion secular frequencies as a function of non-linear field parameters are obtained. The calculated secular frequencies are compared with the results of the homotopy perturbation method and the exact results. With only hexapole superposition, the results of this paper and the homotopy perturbation method are the same and with hexapole and octopole superpositions, the results of this paper are much more closer to the exact results compared with the results of the homotopy perturbation method.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Abrao, Alcidio.; Araujo, Jose Adroaldo de; Franca Junior, J.M.
This paper describes a technique for the production of nuclear grade ammonium diuranate (ADU) using uranyl sulfate solutions obtained as eluate from the ion exchange (strong cationic resin) purification of uranium, by precipitation with NH{sub 3} gas. The precipitation of ADU by direct introduction of NH{sub 3} gas into acid uranyl sulfate solution has as consequence a high coprecipitation of sulfate ion, reaching ratios as high as 10 to 14% SO{sub 4}/ADU. To overcome this serious inconvenience, the reverse order of addition of reagents was studied, the ADU precipitation being done in such a way that the pH of themore » mixture was kept higher than 6 during the whole precipitation. This modification, in conjunction with the adjustment of other precipitation parameters, like temperature, precipitation time, aging time, concentration of uranium in uranyl sulfate and pH, allowed a sucessful precipitation of ADU with low sulfate content. The technique was applied at pilot plant scale, using batch and continuous precipitation, in both cases the obtained ADU was low in sulfate.« less
Development of low-level liquid-waste-treatment systems, October 1981 - March 1982
NASA Astrophysics Data System (ADS)
Williams, M. K.; Colvin, C. M.
1982-05-01
A plant design for a reverse osmosis (RO) membrane unit was completed. The design includes a conceptual diagram, specifications for a RO unit producing 40 gal/min of permeated product, a list of radioisotopes tested on RO units and the rejections achieved, a discussion of the principle of RO, a discussion of the upper limits of cation and anion concentrations (there are no lower limits), a discussion of membrane configurations and porosities, a discussion of factors affecting membranes, a section on calculating the membrane area needed for a particular application, and capital and operating cost calculations. The three factors found to affect the adsorption of cobalt on ion exchange resins were investigated in an interaction effects design experiment. These factors are solution pH, and sulfite and ammonium concentrations. Greater than 99% of the cobalt can usually be removed from solutions at a pH between 3 and 6. A design for an ion-exchange pilot plant was completed.
NASA Astrophysics Data System (ADS)
Wang, Cong; Gai, Guosheng; Yang, Yufen
2018-03-01
Natural microcrystalline graphite (MCG) composed of many crystallites is a promising new anode material for lithium-ion batteries (LiBs) and has received considerable attention from researchers. MCG with narrow particle size distribution and high sphericity exhibits excellent electrochemical performance. A nonaddition process to prepare natural MCG as a high-performance LiB anode material is described. First, raw MCG was broken into smaller particles using a pulverization system. Then, the particles were modified into near-spherical shape using a particle shape modification system. Finally, the particle size distribution was narrowed using a centrifugal rotor classification system. The products with uniform hemispherical shape and narrow size distribution had mean particle size of approximately 9 μm, 10 μm, 15 μm, and 20 μm. Additionally, the innovative pilot experimental process increased the product yield of the raw material. Finally, the electrochemical performance of the prepared MCG was tested, revealing high reversible capacity and good cyclability.
MTBE and priority contaminant treatment with high energy electron beam injection
NASA Astrophysics Data System (ADS)
Cooper, William J.; Nickelsen, Michael G.; Mezyk, Stephen P.; Leslie, Greg; Tornatore, Paul M.; Hardison, Wayne; Hajali, Paris A.
2002-11-01
A study was conducted to examine the removal of methyl tert-butyl ether (MTBE) and 15 other organic compounds, as well as perchlorate ion, in waters of different quality. The 15 organic compounds consisted of halogenated solvents (chlorination), disinfection by-products, pesticides, and nitrosodimethylamine (NDMA). These studies were conducted using a pilot scale 20 kW mobile electron beam system at Water Factory 21, Orange County, CA where wastewater is treated and re-injected into the ground as a barrier to salt water intrusion. Future applications for this treated water include water reuse. Ground water and treated wastewater, after having gone through a reverse osmosis-polishing step (RO permeate), were used to prepare mixtures of the compounds. Using fundamental radiation chemistry, it was possible to examine the factors effecting removal efficiency of all the compounds as well as MTBE destruction and reaction by-product formation and removal. All of the organic compounds were destroyed in the studies and we also observed the destruction of perchlorate ion in one of the waters.
NASA Astrophysics Data System (ADS)
Shadrina, A.; Saruev, L.; Vasenin, S.
2016-09-01
This paper addresses the effectiveness of impact energy use in pilot bore directional drilling at pipe driving. We establish and develop new design-engineering principles for this method. These principles are based on a drill string construction with a new nipple thread connection and a generator construction of strain waves transferred through the drill string. The experiment was conducted on a test bench. Strain measurement is used to estimate compression, tensile, shear and bending stresses in the drill string during the propagation of elastic waves. Finally, the main directions of pilot bore directional drilling improvement during pipe driving are determinated. The new engineering design, as components of the pilot bore directional drilling technology are presented.
Time delays in flight simulator visual displays
NASA Technical Reports Server (NTRS)
Crane, D. F.
1980-01-01
It is pointed out that the effects of delays of less than 100 msec in visual displays on pilot dynamic response and system performance are of particular interest at this time because improvements in the latest computer-generated imagery (CGI) systems are expected to reduce CGI displays delays to this range. Attention is given to data which quantify the effects of display delays in the range of 0-100 msec on system stability and performance, and pilot dynamic response for a particular choice of aircraft dynamics, display, controller, and task. The conventional control system design methods are reviewed, the pilot response data presented, and data for long delays, all suggest lead filter compensation of display delay. Pilot-aircraft system crossover frequency information guides compensation filter specification.
A mixed method pilot study: the researchers' experiences.
Secomb, Jacinta M; Smith, Colleen
2011-08-01
This paper reports on the outcomes of a small well designed pilot study. Pilot studies often disseminate limited or statistically meaningless results without adding to the body knowledge on the comparative research benefits. The design a pre-test post-test group parallel randomised control trial and inductive content analysis of focus group transcripts was tested specifically to increase outcomes in a proposed larger study. Strategies are now in place to overcome operational barriers and recruitment difficulties. Links between the qualitative and quantitative arms of the proposed larger study have been made; it is anticipated that this will add depth to the final report. More extensive reporting on the outcomes of pilot studies would assist researchers and increase the body of knowledge in this area.
Lou, Xianwen; van Dongen, Joost L J; Milroy, Lech-Gustav; Meijer, E W
2016-12-30
Ionization in matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) is a very complicated process. It has been reported that quaternary ammonium salts show extremely strong matrix and analyte suppression effects which cannot satisfactorily be explained by charge transfer reactions. Further investigation of the reasons causing these effects can be useful to improve our understanding of the MALDI process. The dried-droplet and modified thin-layer methods were used as sample preparation methods. In the dried-droplet method, analytes were co-crystallized with matrix, whereas in the modified thin-layer method analytes were deposited on the surface of matrix crystals. Model compounds, tetrabutylammonium iodide ([N(Bu) 4 ]I), cesium iodide (CsI), trihexylamine (THA) and polyethylene glycol 600 (PEG 600), were selected as the test analytes given their ability to generate exclusively pre-formed ions, protonated ions and metal ion adducts respectively in MALDI. The strong matrix suppression effect (MSE) observed using the dried-droplet method might disappear using the modified thin-layer method, which suggests that the incorporation of analytes in matrix crystals contributes to the MSE. By depositing analytes on the matrix surface instead of incorporating in the matrix crystals, the competition for evaporation/ionization from charged matrix/analyte clusters could be weakened resulting in reduced MSE. Further supporting evidence for this inference was found by studying the analyte suppression effect using the same two sample deposition methods. By comparing differences between the mass spectra obtained via the two sample preparation methods, we present evidence suggesting that the generation of gas-phase ions from charged matrix/analyte clusters may induce significant suppression of matrix and analyte ions. The results suggest that the generation of gas-phase ions from charged matrix/analyte clusters is an important ionization step in MALDI-MS. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.
Effect of silver ions and clusters on the luminescence properties of Eu-doped borate glasses
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jiao, Qing, E-mail: jiaoqing@nbu.edu.cn; Wang, Xi; Qiu, Jianbei
2015-12-15
Highlights: • Ag{sup +} and Ag clusters are investigated in the borate glasses via ion exchange method. • The aggregation of silver ions to the clusters was controlled by the ion exchange concentration. • Eu{sup 3+}/Eu{sup 2+} ions emission was enhanced with the sensitization of the silver species. • Energy transfer process from Ag ions and Ag clusters to Eu ions is identified by the lifetime measurements. - Abstract: Silver ions and clusters were applied to Eu{sup 3+}-doped borate glasses via the Ag{sup +}–Na{sup +} ion exchange method. Eu{sup 3+}/Eu{sup 2+} ion luminescence enhancement was achieved after silver ion exchange.more » Absorption spectra showed no band at 420 nm, which indicates that silver nanoparticles can be excluded as a silver state in the glass. Silver ion aggregation into clusters during the ion exchange process may be inferred. The effect of silver ions and clusters on rare earth emissions was investigated using spectral information and lifetime measurements. Significant luminescence enhancements were observed from the energy transfer of Ag{sup +} ions and clusters to Eu{sup 3+}/Eu{sup 2+} ions, companied with the silver ions aggregated into the clusters state. The results of this research may extend the current understanding of interactions between rare-earth ions and Ag species.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Arroyo, F.; Fernandez-Pereira, C.; Olivares, J.
2009-04-15
In this article, a hydrometallurgical method for the selective recovery of germanium from fly ash (FA) has been tested at pilot plant scale. The pilot plant flowsheet comprised a first stage of water leaching of FA, and a subsequent selective recovery of the germanium from the leachate by solvent extraction method. The solvent extraction method was based on Ge complexation with catechol in an aqueous solution followed by the extraction of the Ge-catechol complex (Ge(C{sub 6}H{sub 4}O{sub 2}){sub 3}{sup 2-}) with an extracting organic reagent (trioctylamine) diluted in an organic solvent (kerosene), followed by the subsequent stripping of the organicmore » extract. The process has been tested on a FA generated in an integrated gasification with combined cycle (IGCC) process. The paper describes the designed 5 kg/h pilot plant and the tests performed on it. Under the operational conditions tested, approximately 50% of germanium could be recovered from FA after a water extraction at room temperature. Regarding the solvent extraction method, the best operational conditions for obtaining a concentrated germanium-bearing solution practically free of impurities were as follows: extraction time equal to 20 min; aqueous phase/organic phase volumetric ratio equal to 5; stripping with 1 M NaOH, stripping time equal to 30 min, and stripping phase/organic phase volumetric ratio equal to 5. 95% of germanium were recovered from water leachates using those conditions.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mitchell, W.G.; Spaletto, M.I.; Lewis, K.
The method of plutonium (Pu) determination at the Brunswick Laboratory (NBL) consists of a combination of ion-exchange purification followed by controlled-potential coulometric analysis (IE/CPC). The present report's purpose is to quantify any detectable Pu loss occurring in the ion-exchange (IE) purification step which would cause a negative bias in the NBL method for Pu analysis. The magnitude of any such loss would be contained within the reproducibility (0.05%) of the IE/CPC method which utilizes a state-of-the-art autocoulometer developed at NBL. When the NBL IE/CPC method is used for Pu analysis, any loss in ion-exchange purification (<0.05%) is confounded with themore » repeatability of the ion-exchange and the precision of the CPC analysis technique (<0.05%). Consequently, to detect a bias in the IE/CPC method due to the IE alone using the IE/CPC method itself requires that many randomized analyses on a single material be performed over time and that statistical analysis of the data be performed. The initial approach described in this report to quantify any IE loss was an independent method, Isotope Dilution Mass Spectrometry; however, the number of analyses performed was insufficient to assign a statistically significant value to the IE loss (<0.02% of 10 mg samples of Pu). The second method used for quantifying any IE loss of Pu was multiple ion exchanges of the same Pu aliquant; the small number of analyses possible per individual IE together with the column-to-column variability over multiple ion exchanges prevented statistical detection of any loss of <0.05%. 12 refs.« less
Zhao, P; Takizawa, S; Katayama, H; Ohgaki, S
2005-01-01
Two pilot-scale powdered activated carbon-microfiltration (PAC-MF) reactors were operated using river water pretreated by a biofilter. A high permeate flux (4 m/d) was maintained in two reactors with different particle sizes of PAC. High concentration (20 g/L) in the PAC adsorption zone demonstrated 60-80% of organic removal rates. Analysis on the PAC cake fouling demonstrated that attached metal ions play more important role than organic matter attached on PAC to the increase of PAC cake resistance. Effects of factors which may cause PAC cake fouling in PAC-MF process were investigated and evaluated by batch experiments, further revealing that small particulates and metal ions in raw water impose prominent influence on the PAC cake layer formation. Fe (II) precipitates after being oxidized to Fe (III) during PAC adsorption and thus Fe(ll) colloids display more significant effect than other metal ions. At a high flux, PAC cake layer demonstrated a higher resistance with larger PAC due to association among colloids, metals and PAC particles, and easy migration of small particles in raw water into the void space in the PAC cake layer. Larger PAC possesses much more non-uniform particle size distribution and larger void space, making it easier for small colloids to migrate into the voids and for metal ions to associate with PAC particles by bridge effect, hence speeding up and intensifying the of PAC cake fouling on membrane surface.
Sequencing Larger Intact Proteins (30-70 kDa) with Activated Ion Electron Transfer Dissociation
NASA Astrophysics Data System (ADS)
Riley, Nicholas M.; Westphall, Michael S.; Coon, Joshua J.
2018-01-01
The analysis of intact proteins via mass spectrometry can offer several benefits to proteome characterization, although the majority of top-down experiments focus on proteoforms in a relatively low mass range (<30 kDa). Recent studies have focused on improving the analysis of larger intact proteins (up to 75 kDa), but they have also highlighted several challenges to be addressed. One major hurdle is the efficient dissociation of larger protein ions, which often to do not yield extensive fragmentation via conventional tandem MS methods. Here we describe the first application of activated ion electron transfer dissociation (AI-ETD) to proteins in the 30-70 kDa range. AI-ETD leverages infrared photo-activation concurrent to ETD reactions to improve sequence-informative product ion generation. This method generates more product ions and greater sequence coverage than conventional ETD, higher-energy collisional dissociation (HCD), and ETD combined with supplemental HCD activation (EThcD). Importantly, AI-ETD provides the most thorough protein characterization for every precursor ion charge state investigated in this study, making it suitable as a universal fragmentation method in top-down experiments. Additionally, we highlight several acquisition strategies that can benefit characterization of larger proteins with AI-ETD, including combination of spectra from multiple ETD reaction times for a given precursor ion, multiple spectral acquisitions of the same precursor ion, and combination of spectra from two different dissociation methods (e.g., AI-ETD and HCD). In all, AI-ETD shows great promise as a method for dissociating larger intact protein ions as top-down proteomics continues to advance into larger mass ranges. [Figure not available: see fulltext.
Fighter agility metrics, research, and test
NASA Technical Reports Server (NTRS)
Liefer, Randall K.; Valasek, John; Eggold, David P.
1990-01-01
Proposed new metrics to assess fighter aircraft agility are collected and analyzed. A framework for classification of these new agility metrics is developed and applied. A completed set of transient agility metrics is evaluated with a high fidelity, nonlinear F-18 simulation provided by the NASA Dryden Flight Research Center. Test techniques and data reduction methods are proposed. A method of providing cuing information to the pilot during flight test is discussed. The sensitivity of longitudinal and lateral agility metrics to deviations from the pilot cues is studied in detail. The metrics are shown to be largely insensitive to reasonable deviations from the nominal test pilot commands. Instrumentation required to quantify agility via flight test is also considered. With one exception, each of the proposed new metrics may be measured with instrumentation currently available. Simulation documentation and user instructions are provided in an appendix.
The potential of combining ion trap/MS/MS and TOF/MS for identification of emerging contaminants
Ferrer, I.; Furlong, E.T.; Heine, C.E.; Thurman, E.M.
2002-01-01
The use of a method combining ion trap tandem mass spectrometry (MS/MS) and time of flight mass spectrometry (TOF/MS) for identification of emerging contaminates was discussed. The two tools together complemented each other in sensitivity, fragmentation and accurate mass determination. Liquid chromatography/electrospray ionization/ion-trap tandem mass spectrometry (LC/ESI/MS/MS), in positive ion mode of operation, was used to separate and identify specific compounds. Diagnostic fragment ions were obtained for a polyethyleneglycol(PEG) homolog by ion trap MS/MS, and fragments were measured by TOF/MS. It was observed that the combined method gave an exact mass measurement that differed from the calculated mass.
Ab initio calculation of the ion feature in x-ray Thomson scattering.
Plagemann, Kai-Uwe; Rüter, Hannes R; Bornath, Thomas; Shihab, Mohammed; Desjarlais, Michael P; Fortmann, Carsten; Glenzer, Siegfried H; Redmer, Ronald
2015-07-01
The spectrum of x-ray Thomson scattering is proportional to the dynamic structure factor. An important contribution is the ion feature which describes elastic scattering of x rays off electrons. We apply an ab initio method for the calculation of the form factor of bound electrons, the slope of the screening cloud of free electrons, and the ion-ion structure factor in warm dense beryllium. With the presented method we can calculate the ion feature from first principles. These results will facilitate a better understanding of x-ray scattering in warm dense matter and an accurate measurement of ion temperatures which would allow determining nonequilibrium conditions, e.g., along shock propagation.
Passivated contact formation using ion implantation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Young, David L.; Stradins, Pauls; Nemeth, William
2018-05-29
Methods for forming passivated contacts include implanting compound-forming ions into a substrate to about a first depth below a surface of the substrate, and implanting dopant ions into the substrate to about a second depth below the surface. The second depth may be shallower than the first depth. The methods also include annealing the substrate.
Aksyonov, S A; Williams, P
2001-01-01
Impact desolvation of electrosprayed microdroplets (IDEM) is a new method for producing gas-phase ions of large biomolecules. Analytes are dissolved in an electrolyte solution which is electrosprayed in vacuum, producing highly charged micron and sub-micron sized droplets (microdroplets). These microdroplets are accelerated through potential differences approximately 5 - 10 kV to velocities of several km/s and allowed to impact a target surface. The energetic impacts vaporize the droplets and release desolvated gas-phase ions of the analyte molecules. Oligonucleotides (2- to 12-mer) and peptides (bradykinin, neurotensin) yield singly and doubly charged molecular ions with no detectable fragmentation. Because the extent of multiple charging is significantly less than in atmospheric pressure electrospray ionization, and the method produces ions largely free of adducts from solutions of high ionic strength, IDEM has some promise as a method for coupling to liquid chromatographic techniques and for mixture analysis. Ions are produced in vacuum at a flat equipotential surface, potentially allowing efficient ion extraction. Copyright 2001 John Wiley & Sons, Ltd.
Observation of a high-energy tail in ion energy distribution in the cylindrical Hall thruster plasma
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lim, Youbong; Kim, Holak; Choe, Wonho, E-mail: wchoe@kaist.ac.kr
2014-10-15
A novel method is presented to determine populations and ion energy distribution functions (IEDFs) of individual ion species having different charge states in an ion beam from the measured spectrum of an E × B probe. The inversion of the problem is performed by adopting the iterative Tikhonov regularization method with the characteristic matrices obtained from the calculated ion trajectories. In a cylindrical Hall thruster plasma, an excellent agreement is observed between the IEDFs by an E × B probe and those by a retarding potential analyzer. The existence of a high-energy tail in the IEDF is found to be mainly due to singlymore » charged Xe ions, and is interpreted in terms of non-linear ion acceleration.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mariella, R
The separation of actinides and other elements of interest for nuclear forensics and threat reduction is currently performed using decades-old chemistries and ion-exchange columns. We propose to determine the technical feasibility of a novel method for separating actinide ions in solution. This method is based upon isotachophoresis (ITP), which has been applied in the purification of pharmaceuticals and other biochemical applications. This technique has the potential to separate inorganic ions more effectively than existing methods, which is key to analyzing very small samples. We will perform a quantitative assessment of the effectiveness of specific isotachophoretic approaches including predicting the physicalmore » and chemical properties, such as ion mobility, of inorganic ions under specific solvent conditions using a combination of ab initio calculations and semi-empirical methods. We expect to obtain a thorough understanding of the analytical systems parameters under which ITP is most effective for the separation of inorganic samples, including the influence of the double layer surrounding actinide ions, the Debye length for different ions and ion complexes, and Debye-Hueckel limits. Inorganic separations are key to nuclear forensics for countering terrorism and nuclear proliferation. If found to be feasible and potentially superior to currently used separation approaches, ITP could provide the conceptual basis for an improved means to separate samples of nuclear explosion debris for nuclear forensic analysis, in support of the Laboratory's missions in homeland and national security.« less
NASA Astrophysics Data System (ADS)
Prashanth, K. N.; Swamy, N.; Basavaiah, K.
2013-11-01
Considering the basic property of zolmitriptan (ZMT) to generate ion-pairs with sulfonephthalein dyes two methods have been developed for its assay in bulk drug and dosage form. The first method (method A) is based on the formation of a colored ion-pair complex (1:1 drug:dye) of ZMT with bromocresol green (BCG) at pH 4.20 ± 0.01 and extraction of the complex into chloroform followed by measurement of the yellow ion-pair complex at 435 nm. In the second method (method B), the drug-dye ion-pair complex was treated with ethanolic potassium hydroxide in ethanolic medium and the resulting base form of the dye was measured at 630 nm. Beer's law was obeyed in the concentration range of 0.8-18.0 and 0.08-1.4 μg/ml for method A and B, respectively, and the corresponding molar absorptivity values were 1.50ṡ104 and 1.52ṡ105 l/(molṡcm). The Sandell sensitivity values were 0.0191 and 0.0019 μg/cm2 for method A and method B, respectively. The stoichiometry of the ion-pair complex formed between the drug and dye (1:1) was determined by Job's continuous variation method and the stability constant of the complex was also calculated. The proposed method was successfully extended to dosage form (tablets).
ADSORPTION METHOD FOR SEPARATING THORIUM VALUES FROM URANIUM VALUES
Boyd, G.E.; Russell, E.R.; Schubert, J.
1959-08-01
An improved ion exchange method is described for recovery of uranium and thorium values as separate functions from an aqueous acidic solution containing less than 10/sup -3/ M thorium ions and between 0.1 and 1 M uranyl ions. The solution is passed through a bed of cation exchange resin in the acid form to adsorb all the thorium ions and a portion of the uranyl ions. The uranium is eluted by means of aqueous 0.1 to 0.4 M sulfuric acid. The thorium may then be stripped from the resin by elution with aqueous 0.5 M oxalic acid.
ADSORPTION METHOD FOR SEPARATING THORIUM VALUES FROM URANIUM VALUES
DOE Office of Scientific and Technical Information (OSTI.GOV)
Boyd, G.E.; Russell, E.R.; Schubert, J.
An improved ion exchange method is described for recovery of uranium and thorium values as separate functions from an aqueous acidic solution containing less than 10/sup -3/ M thorium ions and between 0.1 and 1 M uranyl ions. The solution is passed through a bed of cation exchange resin in the acid form to adsorb all the thorium ions and a portion of the uranyl ions. The uranium is eluted by means of aqueous 0.1 to 0.4 M sulfuric acid. The thorium may then be stripped from the resin by elution with aqueous 0.5 M oxalic acid.
Potential mapping with charged-particle beams
NASA Technical Reports Server (NTRS)
Robinson, J. W.; Tillery, D. G.
1979-01-01
Experimental methods of mapping the equipotential surfaces near some structure of interest rely on the detection of charged particles which have traversed the regions of interest and are detected remotely. One method is the measurement of ion energies for ions created at a point of interest and expelled from the region by the fields. The ion energy at the detector in eV corresponds to the potential where the ion was created. An ionizing beam forms the ions from background neutrals. The other method is to inject charged particles into the region of interest and to locate their exit points. A set of several trajectories becomes a data base for a systematic mapping technique. An iterative solution of a boundary value problem establishes concepts and limitations pertaining to the mapping problem.
Optical waveguides in fluoride lead silicate glasses fabricated by carbon ion implantation
NASA Astrophysics Data System (ADS)
Shen, Xiao-liang; Wang, Yue; Zhu, Qi-feng; Lü, Peng; Li, Wei-nan; Liu, Chun-xiao
2018-03-01
The carbon ion implantation with energy of 4.0 MeV and a dose of 4.0×1014 ions/cm2 is employed for fabricating the optical waveguide in fluoride lead silicate glasses. The optical modes as well as the effective refractive indices are measured by the prism coupling method. The refractive index distribution in the fluoride lead silicate glass waveguide is simulated by the reflectivity calculation method (RCM). The light intensity profile and the energy losses are calculated by the finite-difference beam propagation method (FD-BPM) and the program of stopping and range of ions in matter (SRIM), respectively. The propagation properties indicate that the C2+ ion-implanted fluoride lead silicate glass waveguide is a candidate for fabricating optical devices.
Miniature micromachined quadrupole mass spectrometer array and method of making the same
NASA Technical Reports Server (NTRS)
Chutjian, Ara (Inventor); Brennen, Reid A. (Inventor); Hecht, Michael (Inventor); Wiberg, Dean (Inventor); Orient, Otto (Inventor)
2001-01-01
The present invention provides a quadrupole mass spectrometer and an ion filter for use in the quadrupole mass spectrometer. The ion filter includes a thin patterned layer including a two-dimensional array of poles forming one or more quadrupoles. The patterned layer design permits the use of very short poles and with a very dense spacing of the poles, so that the ion filter may be made very small. Also provided is a method for making the ion filter and the quadrupole mass spectrometer. The method involves forming the patterned layer of the ion filter in such a way that as the poles of the patterned layer are formed, they have the relative positioning and alignment for use in a final quadrupole mass spectrometer device.
Miniature micromachined quadrupole mass spectrometer array and method of making the same
NASA Technical Reports Server (NTRS)
Fuerstenau, Stephen D. (Inventor); Yee, Karl Y. (Inventor); Chutjian, Ara (Inventor); Orient, Otto J. (Inventor); Rice, John T. (Inventor)
2002-01-01
The present invention provides a quadrupole mass spectrometer and an ion filter, or pole array, for use in the quadrupole mass spectrometer. The ion filter includes a thin patterned layer including a two-dimensional array of poles forming one or more quadrupoles. The patterned layer design permits the use of very short poles and with a very dense spacing of the poles, so that the ion filter may be made very small. Also provided is a method for making the ion filter and the quadrupole mass spectrometer. The method involves forming the patterned layer of the ion filter in such a way that as the poles of the patterned layer are formed, they have the relative positioning and alignment for use in a final quadrupole mass spectrometer device.
Miniature micromachined quadrupole mass spectrometer array and method of making the same
NASA Technical Reports Server (NTRS)
Chutjian, Ara (Inventor); Rice, John T. (Inventor); Fuerstenau, Stephen D. (Inventor); Orient, Otto J. (Inventor); Yee, Karl Y. (Inventor)
2000-01-01
The present invention provides a quadrupole mass spectrometer and an ion filter, or pole array, for use in the quadrupole mass spectrometer. The ion filter includes a thin patterned layer including a two-dimensional array of poles forming one or more quadrupoles. The patterned layer design permits the use of very short poles and with a very dense spacing of the poles, so that the ion filter may be made very small. Also provided is a method for making the ion filter and the quadrupole mass spectrometer. The method involves forming the patterned layer of the ion filter in such a way that as the poles of the patterned layer are formed, they have the relative positioning and alignment for use in a final quadrupole mass spectrometer device.
Miniature micromachined quadrupole mass spectrometer array and method of making the same
NASA Technical Reports Server (NTRS)
Yee, Karl Y. (Inventor); Fuerstenau, Stephen D. (Inventor); Orient, Otto J. (Inventor); Rice, John T. (Inventor); Chutjian, Ara (Inventor)
2001-01-01
The present invention provides a quadrupole mass spectrometer and an ion filter, or pole array, for use in the quadrupole mass spectrometer. The ion filter includes a thin patterned layer including a two-dimensional array of poles forming one or more quadrupoles. The patterned layer design permits the use of very short poles and with a very dense spacing of the poles, so that the ion filter may be made very small. Also provided is a method for making the ion filter and the quadrupole mass spectrometer. The method involves forming the patterned layer of the ion filter in such a way that as the poles of the patterned layer are formed, they have the relative positioning and alignment for use in a final quadrupole mass spectrometer device.
Miniature micromachined quadrupole mass spectrometer array and method of making the same
NASA Technical Reports Server (NTRS)
Hecht, Michael (Inventor); Wiberg, Dean (Inventor); Orient, Otto (Inventor); Brennen, Reid A. (Inventor); Chutjian, Ara (Inventor)
2001-01-01
The present invention provides a quadrupole mass spectrometer and an ion filter for use in the quadrupole mass spectrometer. The ion filter includes a thin patterned layer including a two-dimensional array of poles forming one or more quadrupoles. The patterned layer design permits the use of very short poles and with a very dense spacing of the poles, so that the ion filter may be made very small. Also provided is a method for making the ion filter and the quadrupole mass spectrometer. The method involves forming the patterned layer of the ion filter in such a way that as the poles of the patterned layer are formed, they have the relative positioning and aligrnent for use in a final quadrupole mass spectrometer device.
Miniature micromachined quadrupole mass spectrometer array and method of making the same
NASA Technical Reports Server (NTRS)
Orient, Otto (Inventor); Wiberg, Dean (Inventor); Brennen, Reid A. (Inventor); Hecht, Michael (Inventor); Chutjian, Ara (Inventor)
2000-01-01
The present invention provides a quadrupole mass spectrometer and an ion filter for use in the quadrupole mass spectrometer. The ion filter includes a thin patterned layer including a two-dimensional array of poles forming one or more quadrupoles. The patterned layer design permits the use of very short poles and with a very dense spacing of the poles, so that the ion filter may be made very small. Also provided is a method for making the ion filter and the quadrupole mass spectrometer. The method involves forming the patterned layer of the ion filter in such a way that as the poles of the patterned layer are formed, they have the relative positioning and alignment for use in a final quadrupole mass spectrometer device.
Lopez-Alvarez, Blady; Torres-Palma, Ricardo A; Ferraro, Franklin; Peñuela, Gustavo
2012-01-01
The degradation of the pesticide carbofuran (CBF) using solar photo-Fenton treatment, at both the laboratory and the pilot scale, was evaluated. At the laboratory scale, in a suntest reactor, the Fe(2+) concentration and H(2)O(2) concentration were evaluated and optimized using the surface response methodology and the Pareto diagram. Under optimal conditions experiments were performed to evaluate the evolution of the substrate removal, oxidation, subsequent mineralization, toxicity and the formation of chloride ions during the treatment. The analysis and evolution of five CBF by-products as well as several control and reactivity tests at the density functional theory level were used to depict a general scheme of the main degradation pathway of CBF via the photo-Fenton system. Finally, at the pilot scale, a sample of the commercial CBF product Furadan was eliminated after 420 min by the photo-Fenton system using direct sunlight. Under these conditions, after 900 min 89% of toxicity (1/E(50) on Vibrio fischeri bacteria), 97% of chemical oxygen demand, and 90% of dissolved organic carbon were removed.
NASA Astrophysics Data System (ADS)
Prashanth, K. N.; Basavaiah, K.
2018-01-01
Two simple and sensitive extraction-free spectrophotometric methods are described for the determination of flunarizine dihydrochloride. The methods are based on the ion-pair complex formation between the nitrogenous compound flunarizine (FNZ), converted from flunarizine dihydrochloride (FNH), and the acidic dye phenol red (PR), in which experimental variables were circumvented. The first method (method A) is based on the formation of a yellow-colored ion-pair complex (1:1 drug:dye) between FNZ and PR in chloroform, which is measured at 415 nm. In the second method (method B), the formed drug-dye ion-pair complex is treated with ethanolic potassium hydroxide in an ethanolic medium, and the resulting base form of the dye is measured at 580 nm. The stoichiometry of the formed ion-pair complex between the drug and dye (1:1) is determined by Job's continuous variations method, and the stability constant of the complex is also calculated. These methods quantify FNZ over the concentration ranges 5.0-70.0 in method A and 0.5-7.0 μg/mL in method B. The calculated molar absorptivities are 6.17 × 103 and 5.5 × 104 L/mol·cm-1 for method A and method B, respectively, with corresponding Sandell sensitivity values of 0.0655 and 0.0074 μg/cm2. The methods are applied to the determination of FNZ in pure drug and human urine.
Universal collisional activation ion trap mass spectrometry
McLuckey, S.A.; Goeringer, D.E.; Glish, G.L.
1993-04-27
A universal collisional activation ion trap comprises an ion trapping means containing a bath gas and having connected thereto a noise signal generator. A method of operating a universal collisional activation ion trap comprises the steps of: providing an ion trapping means; introducing into the ion trapping means a bath gas; and, generating a noise signal within the ion trapping means; introducing into the ion trapping means a substance that, when acted upon by the noise signal, undergoes collisional activation to form product ions.
Universal collisional activation ion trap mass spectrometry
McLuckey, Scott A.; Goeringer, Douglas E.; Glish, Gary L.
1993-01-01
A universal collisional activation ion trap comprises an ion trapping means containing a bath gas and having connected thereto a noise signal generator. A method of operating a universal collisional activation ion trap comprises the steps of: providing an ion trapping means; introducing into the ion trapping means a bath gas; and, generating a noise signal within the ion trapping means; introducing into the ion trapping means a substance that, when acted upon by the noise signal, undergoes collisional activation to form product ions.
Hyperintense White Matter Lesions in 50 High-Altitude Pilots With Neurologic Decompression Sickness
McGuire, Stephen A.; Sherman, Paul M.; Brown, Anthony C.; Robinson, Andrew Y.; Tate, David F.; Fox, Peter T.; Kochunov, Peter V.
2013-01-01
Introduction Neurologic decompression sickness (NDCS) can affect high-altitude pilots, causing variable central nervous system symptoms. Five recent severe episodes prompted further investigation. Methods We report the hyperintense white matter (HWM) lesion imaging findings in 50 U-2 pilot volunteers, and compare 12 U-2 pilots who experienced clinical NDCS to 38 U-2 pilots who did not. The imaging data were collected using a 3T magnetic resonance imaging scanner and high-resolution (1-mm isotropic) three-dimensional fluid-attenuated inversion recovery sequence. Whole-brain and regional lesion volume and number were compared between groups. Results The NDCS group had significantly increased whole brain and insular volumes of HWM lesions. The intergroup difference in lesion numbers was not significant. Conclusion A clinical episode of NDCS was associated with a significant increase in HWM lesion volume, especially in the insula. We postulate this to be due to hypobaric exposure rather than hypoxia since all pilots were maintained on 100% oxygen throughout the flight. Further studies will be necessary to better understand the pathophysiology underlying these lesions. PMID:23316539
Evaluation of Pulse Counting for the Mars Organic Mass Analyzer (MOMA) Ion Trap Detection Scheme
NASA Technical Reports Server (NTRS)
Van Amerom, Friso H.; Short, Tim; Brinckerhoff, William; Mahaffy, Paul; Kleyner, Igor; Cotter, Robert J.; Pinnick, Veronica; Hoffman, Lars; Danell, Ryan M.; Lyness, Eric I.
2011-01-01
The Mars Organic Mass Analyzer is being developed at Goddard Space Flight Center to identify organics and possible biological compounds on Mars. In the process of characterizing mass spectrometer size, weight, and power consumption, the use of pulse counting was considered for ion detection. Pulse counting has advantages over analog-mode amplification of the electron multiplier signal. Some advantages are reduced size of electronic components, low power consumption, ability to remotely characterize detector performance, and avoidance of analog circuit noise. The use of pulse counting as a detection method with ion trap instruments is relatively rare. However, with the recent development of high performance electrical components, this detection method is quite suitable and can demonstrate significant advantages over analog methods. Methods A prototype quadrupole ion trap mass spectrometer with an internal electron ionization source was used as a test setup to develop and evaluate the pulse-counting method. The anode signal from the electron multiplier was preamplified. The an1plified signal was fed into a fast comparator for pulse-level discrimination. The output of the comparator was fed directly into a Xilinx FPGA development board. Verilog HDL software was written to bin the counts at user-selectable intervals. This system was able to count pulses at rates in the GHz range. The stored ion count nun1ber per bin was transferred to custom ion trap control software. Pulse-counting mass spectra were compared with mass spectra obtained using the standard analog-mode ion detection. Prelin1inary Data Preliminary mass spectra have been obtained for both analog mode and pulse-counting mode under several sets of instrument operating conditions. Comparison of the spectra revealed better peak shapes for pulse-counting mode. Noise levels are as good as, or better than, analog-mode detection noise levels. To artificially force ion pile-up conditions, the ion trap was overfilled and ions were ejected at very high scan rates. Pile-up of ions was not significant for the ion trap under investigation even though the ions are ejected in so-called 'ion-micro packets'. It was found that pulse counting mode had higher dynamic range than analog mode, and that the first amplification stage in analog mode can distort mass peaks. The inherent speed of the pulse counting method also proved to be beneficial to ion trap operation and ion ejection characterization. Very high scan rates were possible with pulse counting since the digital circuitry response time is so much smaller than with the analog method. Careful investigation of the pulse-counting data also allowed observation of the applied resonant ejection frequency during mass analysis. Ejection of ion micro packets could be clearly observed in the binned data. A second oscillation frequency, much lower than the secular frequency, was also observed. Such an effect was earlier attributed to the oscillation of the total plasma cloud in the ion trap. While the components used to implement pulse counting are quite advanced, due to their prevalence in consumer electronics, the cost of this detection system is no more than that of an analog mode system. Total pulse-counting detection system electronics cost is under $250
Pilot Alcohol Violations Reported in U.S. Newspapers, 1990–2006
Kraus, Chadd K.; Li, Guohua
2009-01-01
Introduction Alcohol violations by airline pilots are rare yet remain a public concern. Such incidents often generate widespread news coverage. This study examines the frequency and characteristics of alcohol violation incidents involving airline pilots reported in U.S. newspapers. Methods The database of Lexis-Nexis™, which contains full-text articles for over 350 newspapers, was searched to identify alcohol violation incidents involving airline pilots in the U.S. between January 1990 and June 2006. Information pertaining to the pilot, flight, blood alcohol concentration (BAC), and consequence was ascertained for each incident based on the newspaper coverage. Results During the study period, newspapers reported on a total of 13 incidents of alcohol violations involving 17 pilots. All but two of the incidents occurred during January 2002 through June 2006. The majority (85%) of the incidents were first identified by airport personnel, such as security screeners, based on suspicion of alcohol use by the pilot. Subsequent alcohol testing revealed a mean BAC of 90 mg/dL (ranging from 10 mg · dL−1 to 182 mg · dL−1). Of the 17 pilots, 6 were known to be prosecuted criminally, including 5 who were sentenced to jail terms. Discussion Incidents of alcohol violations by airline pilots reported in U.S. newspapers have increased in recent years. This increase is likely due in part to increased detection resulting from enhanced aviation security and enforcement following the September 2001 terrorist attacks. PMID:17183928
Bearman, Chris; Paletz, Susannah B F; Orasanu, Judith; Brooks, Benjamin P
2009-12-01
Recent attention has focused on the way in which organizational factors can erode safety in aviation, particularly in regions that have a high accident rate, such as Alaska. The present study builds on this work by examining the direct and indirect pressures that can be exerted on pilots by Alaskan operators. In addition, the paper examines ways in which organizations and individuals manage the effects of pressure. Using the critical incident method to uncover situations where the pilot's skills had been challenged, 28 pilots who flew in Alaska were interviewed. A bottom-up qualitative analysis revealed a range of organizational pressures and mitigating strategies. Pilots in Alaska encountered both implicit and explicit norms and expectations to fly in marginal conditions. Pressure also arose from pilots' awareness of the need for their company to make money and from perceived job competition. Some Alaskan operators were able to mitigate the effects of pressure on their pilots and some pilots reported mitigating pressure to fly by managing their employer's expectations and re-emphasizing safety. Organizational factors were found to be an important source of pressure for pilots and are likely to contribute to the high accident rate in Alaska. Balancing the competing demands of safety and productivity may be extremely difficult for many small operators, which places a heavy reliance on the decision making of individuals. Both the subtle pressures on individual pilots and strategies for mitigating those pressures are, therefore, extremely important to safety and productivity in small-scale commercial aviation.
Zhou, Xiaoyu; Ouyang, Zheng
2016-07-19
Ion trajectory simulation is an important and useful tool in instrumentation development for mass spectrometry. Accurate simulation of the ion motion through the mass spectrometer with atmospheric pressure ionization source has been extremely challenging, due to the complexity in gas hydrodynamic flow field across a wide pressure range as well as the computational burden. In this study, we developed a method of generating the gas flow field for an entire mass spectrometer with an atmospheric pressure interface. In combination with the electric force, for the first time simulation of ion trajectories from an atmospheric pressure ion source to a mass analyzer in vacuum has been enabled. A stage-by-stage ion repopulation method has also been implemented for the simulation, which helped to avoid an intolerable computational burden for simulations at high pressure regions while it allowed statistically meaningful results obtained for the mass analyzer. It has been demonstrated to be suitable to identify a joint point for combining the high and low pressure fields solved individually. Experimental characterization has also been done to validate the new method for simulation. Good agreement was obtained between simulated and experimental results for ion transfer though an atmospheric pressure interface with a curtain gas.
NASA Astrophysics Data System (ADS)
Suyama, Taku; Bae, Hansin; Setaka, Kenta; Ogawa, Hayato; Fukuoka, Yushi; Suzuki, Haruka; Toyoda, Hirotaka
2017-11-01
O- ion flux from the indium tin oxide (ITO) sputter target under Ar ion bombardment is quantitatively evaluated using a calorimetry method. Using a mass spectrometer with an energy analyzer, O- energy distribution is measured with spatial dependence. Directional high-energy O- ion ejected from the target surface is observed. Using a calorimetry method, localized heat flux originated from high-energy O- ion is measured. From absolute evaluation of the heat flux from O- ion, O- particle flux in order of 1018 m-2 s-1 is evaluated at a distance of 10 cm from the target. Production yield of O- ion on the ITO target by one Ar+ ion impingement at a kinetic energy of 244 eV is estimated to be 3.3 × 10-3 as the minimum value.
A Study of Green's Function Methods Applied to Space Radiation Protection
NASA Technical Reports Server (NTRS)
Heinbockel, John H.
2001-01-01
The purpose of this research was to study the propagation of galactic ions through various materials. Galactic light ions result from the break up of heavy ion particles and their propagation through materials is modeled using the one-dimensional Boltzmann equation. When ions enter materials there can occur (i) the interaction of ions with orbital electrons which causes ionization within the material and (ii) ions collide with atoms causing production of secondary particles which penetrate deeper within the material. These processes are modeled by a continuum model. The basic idea is to place a control volume within the material and examine the change in ion flux across this control volume. In this way on can derive the basic equations for the transport of light and heavy ions in matter. Green's function perturbation methods can then be employed to solve the resulting equations using energy dependent nuclear cross sections.
Electric field measurement in microwave discharge ion thruster with electro-optic probe.
Ise, Toshiyuki; Tsukizaki, Ryudo; Togo, Hiroyoshi; Koizumi, Hiroyuki; Kuninaka, Hitoshi
2012-12-01
In order to understand the internal phenomena in a microwave discharge ion thruster, it is important to measure the distribution of the microwave electric field inside the discharge chamber, which is directly related to the plasma production. In this study, we proposed a novel method of measuring a microwave electric field with an electro-optic (EO) probe based on the Pockels effect. The probe, including a cooling system, contains no metal and can be accessed in the discharge chamber with less disruption to the microwave distribution. This method enables measurement of the electric field profile under ion beam acceleration. We first verified the measurement with the EO probe by a comparison with a finite-difference time domain numerical simulation of the microwave electric field in atmosphere. Second, we showed that the deviations of the reflected microwave power and the beam current were less than 8% due to inserting the EO probe into the ion thruster under ion beam acceleration. Finally, we successfully demonstrated the measurement of the electric-field profile in the ion thruster under ion beam acceleration. These measurements show that the electric field distribution in the thruster dramatically changes in the ion thruster under ion beam acceleration as the propellant mass flow rate increases. These results indicate that this new method using an EO probe can provide a useful guide for improving the propulsion of microwave discharge ion thrusters.
A new battery-charging method suggested by molecular dynamics simulations.
Abou Hamad, Ibrahim; Novotny, M A; Wipf, D O; Rikvold, P A
2010-03-20
Based on large-scale molecular dynamics simulations, we propose a new charging method that should be capable of charging a lithium-ion battery in a fraction of the time needed when using traditional methods. This charging method uses an additional applied oscillatory electric field. Our simulation results show that this charging method offers a great reduction in the average intercalation time for Li(+) ions, which dominates the charging time. The oscillating field not only increases the diffusion rate of Li(+) ions in the electrolyte but, more importantly, also enhances intercalation by lowering the corresponding overall energy barrier.
Pilot evaluation of the efficacy of shampoo treatment with ultrapure soft water for canine pruritus.
Ohmori, Keitaro; Tanaka, Akane; Makita, Yuka; Takai, Masaki; Yoshinari, Yuji; Matsuda, Hiroshi
2010-10-01
Ultrapure soft water (UPSW) is water in which calcium and magnesium ions have been replaced with sodium ions using a cation-exchange resin. We recently demonstrated that washing with soap and UPSW reduced the clinical severity of dermatitis and improved the skin barrier function in NC/NgaTnd mice, a murine model for human atopic dermatitis. The purpose of this pilot study was to evaluate the efficacy of shampoo treatment with UPSW for dogs with pruritus. Eleven dogs with pruritus were randomly assigned to two groups depending on whether they received weekly shampoo treatment with UPSW or tap water for 4 weeks. After a washout period, the treatment protocol was switched such that each dog received both treatments. The pre-treatment and post-treatment values of the following were compared: pruritus scores assessed by the owners; dermatitis scores recorded by an investigator; and transepidermal water loss (TEWL). Shampoo treatment with UPSW significantly decreased pruritus and dermatitis scores in the dogs, whereas shampoo treatment with tap water did not. In addition, shampoo treatment with UPSW, but not with tap water, significantly reduced TEWL in the dogs. Adverse events due to the treatment were not observed in the dogs. Furthermore, we found that topical application of UPSW for barrier-disrupted skin caused by tape stripping in healthy dogs decreased TEWL more rapidly than topical application of tap water. Our findings suggest that shampoo treatment with UPSW promotes skin barrier recovery and thus could be considered as a possible therapeutic option in the management of pruritus and dermatitis in dogs. © 2010 The Authors. Journal compilation © 2010 ESVD and ACVD.
Siegel, M.D.; Anderholm, S.
1994-01-01
The Culebra Dolomite Member of the Rustler Formation, a thin (10 m) fractured dolomite aquifer, lies approximately 450 m above the repository horizon of the Waste Isolation Pilot Plant (WIPP) in southeastern New Mexico, USA. Salinities of water in the Culebra range roughly from 10,000 to 200,000 mg/L within the WIPP site. A proposed model for the post-Pleistocene hydrochemical evolution of the Culebra tentatively identifies the major sources and sinks for many of the groundwater solutes. Reaction-path simulations with the PHRQPITZ code suggest that the Culebra dolomite is a partial chemical equilibrium system whose composition is controlled by an irreversible process (dissolution of evaporites) and equilibrium with gypsum and calcite. Net geochemical reactions along postulated modern flow paths, calculated with the NETPATH code, include dissolution of halite, carbonate and evaporite salts, and ion exchange. R-mode principal component analysis revealed correlations among the concentrations of Si, Mg, pH, Li, and B that are consistent with several clay-water reactions. The results of the geochemical calculations and mineralogical data are consistent with the following hydrochemical model: 1. (1) solutes are added to the Culebra by dissolution of evaporite minerals 2. (2) the solubilities of gypsum and calcite increase as the salinity increases; these minerals dissolve as chemical equilibrium is maintained between them and the groundwater 3. (3) equilibrium is not maintained between the waters and dolomite; sufficient Mg is added to the waters by dissolution of accessory carnallite or polyhalite such that the degree of dolomite supersaturation increases with ionic strength 4. (4) clays within the fractures and rock matrix exert some control on the distribution of Li, B, Mg, and Si via sorption, ion exchange, and dissolution. ?? 1994.
Enhanced capacity and stability for the separation of cesium in electrically switched ion exchange
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tawfic, A.F.; Dickson, S.E.; Kim, Y.
2015-03-15
Electrically switched ion exchange (ESIX) can be used to separate ionic contaminants from industrial wastewater, including that generated by the nuclear industry. The ESIX method involves sequential application of reduction and oxidation potentials to an ion exchange film to induce the respective loading and unloading of cesium. This technology is superior to conventional methods (e.g electrodialysis reversal or reverse osmosis) as it requires very little energy for ionic separation. In previous studies, ESIX films have demonstrated relatively low ion exchange capacities and limited film stabilities over repeated potential applications. In this study, the methodology for the deposition of electro-active filmsmore » (nickel hexacyanoferrate) on nickel electrodes was modified to improve the ion exchange capacity for cesium removal using ESIX. Cyclic voltammetry was used to investigate the ion exchange capacity and stability. Scanning electron microscopy (SEM) was used to characterize the modified film surfaces. Additionally, the films were examined for the separation of cesium ions. This modified film preparation technique enhanced the ion exchange capacity and improves the film stability compared to previous methods for the deposition of ESIX films. (authors)« less
Drenkova-Tuhtan, Asya; Mandel, Karl; Paulus, Anja; Meyer, Carsten; Hutter, Frank; Gellermann, Carsten; Sextl, Gerhard; Franzreb, Matthias; Steinmetz, Heidrun
2013-10-01
An innovative nanocomposite material is proposed for phosphate recovery from wastewater using magnetic assistance. Superparamagnetic microparticles modified with layered double hydroxide (LDH) ion exchangers of various compositions act as phosphate adsorbers. Magnetic separation and chemical regeneration of the particles allows their reuse, leading to the successful recovery of phosphate. Based upon the preliminary screening of different LDH ion exchanger modifications for phosphate selectivity and uptake capacity, MgFe-Zr LDH coated magnetic particles were chosen for further characterization and application. The adsorption kinetics of phosphate from municipal wastewater was studied in dependence with particle concentration, contact time and pH. Adsorption isotherms were then determined for the selected particle system. Recovery of phosphate and regeneration of the particles was examined via testing a variety of desorption solutions. Reusability of the particles was demonstrated for 15 adsorption/desorption cycles. Adsorption in the range of 75-97% was achieved in each cycle after 1 h contact time. Phosphate recovery and enrichment was possible through repetitive application of the desorption solution. Finally, a pilot scale experiment was carried out by treating 125 L of wastewater with the particles in five subsequent 25 L batches. Solid-liquid separation on this scale was carried out with a high-gradient magnetic filter (HGMF). Copyright © 2013 Elsevier Ltd. All rights reserved.
Atomic ion clock with two ion traps, and method to transfer ions
NASA Technical Reports Server (NTRS)
Prestage, John D. (Inventor); Chung, Sang K. (Inventor)
2011-01-01
An atomic ion clock with a first ion trap and a second ion trap, where the second ion trap is of higher order than the first ion trap. In one embodiment, ions may be shuttled back and forth from one ion trap to the other by application of voltage ramps to the electrodes in the ion traps, where microwave interrogation takes place when the ions are in the second ion trap, and fluorescence is induced and measured when the ions are in the first ion trap. In one embodiment, the RF voltages applied to the second ion trap to contain the ions are at a higher frequency than that applied to the first ion trap. Other embodiments are described and claimed.
Zhou, Qingxiang; Lei, Man; Liu, Yongli; Wu, Yalin; Yuan, Yongyong
2017-12-01
Pollution resulted from heavy metal ions have absorbed much attention, and it is of great importance to develop sensitive and simultaneous determination method for them with common technologies without highly sensitive instruments. We prepared a new and functional core-shell magnetic nano-material, Fe@Ag@dimercaptobenzene (Fe@Ag@DMB), by a one-step method with sodium borohydride as the reducing agent and transmission electron microscopy (TEM) and energy dispersive spectrometer (EDS) were used for characterisation. The mercapto functional groups on the newly synthesised magnetic nanoparticles could interact with Cd 2+ , Pb 2+ , and Hg 2+ ions in water samples and then efficient extraction for Cd 2+ , Pb 2+ , and Hg 2+ ions was achieved. DDTC-Na solution was a good elutent for elution of these ions from Fe@Ag@DMB nanoparticles. Based on these, a sensitive method was developed for simultaneous preconcentration and determination of the aforementioned ions using magnetic Fe@Ag@DMB nanoparticles as the magnetic solid phase extraction adsorbent prior to high performance liquid chromatography coupled with variable wavelength detection. Under the optimal conditions, the detection limits of the three metal ions were in the range of 0.011-0.031μgL -1 , and precisions were below 2.37% (n=6). The proposed method was evaluated with real water samples, and excellent spiked recoveries achieved indicated that the developed method would be a promising tool for monitoring these heavy metal ions in water samples. Copyright © 2017 Elsevier B.V. All rights reserved.
Ghaedi, Mehrorang; Asadpour, Enayat; Vafaie, Azam
2006-01-01
A simple and accurate micellanized spectrophotometric method for determination of trace amounts of Cr(III) ion in tab and top water and a synthetic mixture has been described. The micellar method is based on effect of organized molecular assemblies such as micelles in spectrophotometric measurement due to their effect on the systems of interest. The ability of micellar system in solubilizing of sparingly soluble ligand or complexes has been used for increasing figures of merit of an analytical method. Due to solubility increasing in aqueous media requirement for a primary extraction can be eliminated. Using the alpha-benzoin oxime (alpha-BO) spectrophotometric determination of Cr(III) ion has been performed and results are compared. The spectrophotometric determination of Cr(III) ion using alpha-BO in the presence of non-ionic surfactant Triton X-100 has been performed. The influence of type and amount of surfactant, pH, complexation time and amount of ligand were examined. Finally, the repeatability, accuracy and the effect of interfering ions on the determination of Cr(III) ion was evaluated. The proposed methods successfully with recovery yield of almost 100% have been applied to the rapid and simple determination of Cr(III) ion in the real samples. There is a good agreement between methods and atomic absorption spectrometry. The Beers law is obeyed over the concentration range of 0.1-13.7 microg mL(-1) for micellar media. The detection limit is 0.8 ng mL(-1). The molar absorptivity of complex is 5350 L mol(-1) cm(-1).
NASA Astrophysics Data System (ADS)
Ghaedi, Mehrorang; Asadpour, Enayat; Vafaie, Azam
2006-01-01
A simple and accurate micellanized spectrophotometric method for determination of trace amounts of Cr(III) ion in tab and top water and a synthetic mixture has been described. The micellar method is based on effect of organized molecular assemblies such as micelles in spectrophotometric measurement due to their effect on the systems of interest. The ability of micellar system in solubilizing of sparingly soluble ligand or complexes has been used for increasing figures of merit of an analytical method. Due to solubility increasing in aqueous media requirement for a primary extraction can be eliminated. Using the α-benzoin oxime (α-BO) spectrophotometric determination of Cr(III) ion has been performed and results are compared. The spectrophotometric determination of Cr(III) ion using α-BO in the presence of non-ionic surfactant Triton X-100 has been performed. The influence of type and amount of surfactant, pH, complexation time and amount of ligand were examined. Finally, the repeatability, accuracy and the effect of interfering ions on the determination of Cr(III) ion was evaluated. The proposed methods successfully with recovery yield of almost 100% have been applied to the rapid and simple determination of Cr(III) ion in the real samples. There is a good agreement between methods and atomic absorption spectrometry. The Beers law is obeyed over the concentration range of 0.1-13.7 μg mL-1 for micellar media. The detection limit is 0.8 ng mL-1. The molar absorptivity of complex is 5350 L mol-1 cm-1.
Modification of WS2 nanosheets with controllable layers via oxygen ion irradiation
NASA Astrophysics Data System (ADS)
Song, Honglian; Yu, Xiaofei; Chen, Ming; Qiao, Mei; Wang, Tiejun; Zhang, Jing; Liu, Yong; Liu, Peng; Wang, Xuelin
2018-05-01
As one kind of two-dimensional materials, WS2 nanosheets have drawn much attention with different kinds of research methods. Yet ion irradiation method was barely used for WS2 nanosheets. In this paper, the structure, composition and optical band gap (Eg) of the multilayer WS2 films deposited by chemical vapor deposition (CVD) method on sapphire substrates before and after oxygen ion irradiation with different energy and fluences were studied. Precise tailored layer-structures and a controllable optical band gap of WS2 nanosheets were achieved after oxygen ion irradiation. The results shows higher energy oxygen irradiation changed the shape from triangular shaped grains to irregular rectangle shape but did not change 2H-WS2 phase structure. The intensity of E2g1 (Г) and A1g (Г) modes decreased and have small shifts after oxygen ion irradiation. The peak frequency difference between the E2g1 (Г) and A1g (Г) modes (Δω) decreased after oxygen ion irradiation, and this result indicates the number of layers decreased after oxygen ion irradiation. The Eg decreased with the increase of the energy and the fluence of oxygen ions. The number of layers, thickness and optical band gap changed after ion irradiation with different ion fluences and energies. The results proposed a new strategy for precise control of multilayer nanosheets and demonstrated the high applicability of ion irradiation in super-capacitors, field effect transistors and other applications.
In situ methods for Li-ion battery research: A review of recent developments
NASA Astrophysics Data System (ADS)
Harks, P. P. R. M. L.; Mulder, F. M.; Notten, P. H. L.
2015-08-01
A considerable amount of research is being directed towards improving lithium-ion batteries in order to meet today's market demands. In particular in situ investigations of Li-ion batteries have proven extremely insightful, but require the electrochemical cell to be fully compatible with the conditions of the testing method and are therefore often challenging to execute. Advantageously, in the past few years significant progress has been made with new, more advanced, in situ techniques. Herein, a comprehensive overview of in situ methods for studying Li-ion batteries is given, with the emphasis on new developments and reported experimental highlights.
Production of large resonant plasma volumes in microwave electron cyclotron resonance ion sources
Alton, Gerald D.
1998-01-01
Microwave injection methods for enhancing the performance of existing electron cyclotron resonance (ECR) ion sources. The methods are based on the use of high-power diverse frequency microwaves, including variable-frequency, multiple-discrete-frequency, and broadband microwaves. The methods effect large resonant "volume" ECR regions in the ion sources. The creation of these large ECR plasma volumes permits coupling of more microwave power into the plasma, resulting in the heating of a much larger electron population to higher energies, the effect of which is to produce higher charge state distributions and much higher intensities within a particular charge state than possible in present ECR ion sources.
Extending the frontiers of mass spectrometric instrumentation and methods
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schieffer, Gregg Martin
2010-01-01
The focus of this dissertation is two-fold: developing novel analysis methods using mass spectrometry and the implementation and characterization of a novel ion mobility mass spectrometry instrumentation. The novel mass spectrometry combines ion trap for ion/ion reactions coupled to an ion mobility cell. The long term goal of this instrumentation is to use ion/ion reactions to probe the structure of gas phase biomolecule ions. The three ion source - ion trap - ion mobility - qTOF mass spectrometer (IT - IM - TOF MS) instrument is described. The analysis of the degradation products in coal (Chapter 2) and the imagingmore » plant metabolites (Appendix III) fall under the methods development category. These projects use existing commercial instrumentation (JEOL AccuTOF MS and Thermo Finnigan LCQ IT, respectively) for the mass analysis of the degraded coal products and the plant metabolites, respectively. The coal degradation paper discusses the use of the DART ion source for fast and easy sample analysis. The sample preparation consisted of a simple 50 fold dilution of the soluble coal products in water and placing the liquid in front of the heated gas stream. This is the first time the DART ion source has been used for analysis of coal. Steven Raders under the guidance of John Verkade came up with the coal degradation projects. Raders performed the coal degradation reactions, worked up the products, and sent them to me. Gregg Schieffer developed the method and wrote the paper demonstrating the use of the DART ion source for the fast and easy sample analysis. The plant metabolite imaging project extends the use of colloidal graphite as a sample coating for atmospheric pressure LDI. DC Perdian and I closely worked together to make this project work. Perdian focused on building the LDI setup whereas Schieffer focused on the MSn analysis of the metabolites. Both Perdian and I took the data featured in the paper. Perdian was the primary writer of the paper and used it as a chapter in his dissertation. Perdian and Schieffer worked together to address the revisions and publish it in Rapid Communications in Mass Spectrometry Journal.« less
Hersam, Mark C.; Lipson, Albert L.; Bandyopadhyay, Sudeshna; Karmel, Hunter J; Bedzyk, Michael J
2014-05-27
A method for enhancing the lithium-ion capacity of a doped silicon carbide is disclosed. The method utilizes heat treating the silicon carbide in an inert atmosphere. Also disclosed are anodes for lithium-ion batteries prepared by the method.
Evaluation of the Use of Team Teaching for Delivering Sensitive Content: A Pilot Study
ERIC Educational Resources Information Center
Kerridge, Joanna; Kyle, Gaye; Marks-Maran, Diane
2009-01-01
Many programmes in further and higher education contain sensitive areas of content, such as diversity, racism, power and privilege, breaking bad news, counselling, sex education and ethical decision making. Team teaching may be a useful method for delivering sensitive areas of course content. This article presents a pilot study that was undertaken…
ERIC Educational Resources Information Center
Purifoy, George R., Jr.
This report presents a detailed description of the methods by which airborne video recording will be utilized in training Air Force pilots, and presents the format for an experiment testing the effectiveness of such training. Portable airborne recording with ground playback permits more economical and efficient teaching of the critical visual and…
Pilot Study: Impact of Computer Simulation on Students' Economic Policy Performance. Pilot Study.
ERIC Educational Resources Information Center
Domazlicky, Bruce; France, Judith
Fiscal and monetary policies taught in macroeconomic principles courses are concepts that might require both lecture and simulation methods. The simulation models, which apply the principles gleened from comparative statistics to a dynamic world, may give students an appreciation for the problems facing policy makers. This paper is a report of a…
ERIC Educational Resources Information Center
Connelly, E. M.; And Others
A new approach to deriving human performance measures and criteria for use in automatically evaluating trainee performance is described. Ultimately, this approach will allow automatic measurement of pilot performance in a flight simulator or from recorded in-flight data. An efficient method of representing performance data within a computer is…
Bupropion SR in Adolescents with Comorbid ADHD and Nicotine Dependence: A Pilot Study
ERIC Educational Resources Information Center
Upadhyaya, Himanshu P.; Brady, Kathleen T.; Wang, Wei
2004-01-01
Objective: Bupropion SR has been shown to be effective for the treatment of nicotine dependence in adults. This open-label pilot study was designed to examine the feasibility and preliminary tolerability of bupropion SR in adolescents with nicotine dependence. Method: Sixteen adolescents aged 12 to 19 years were enrolled in the study. Eleven of…
ERIC Educational Resources Information Center
Logan, Christopher W.; Cole, Nancy; Kamara, Sheku G.
2010-01-01
Purpose/Objectives: The Direct Verification Pilot tested the feasibility, effectiveness, and costs of using Medicaid and State Children's Health Insurance Program (SCHIP) data to verify applications for free and reduced-price (FRP) school meals instead of obtaining documentation from parents and guardians. Methods: The Direct Verification Pilot…
Social and Emotional Education with Australian Year 7 and 8 Middle School Students: A Pilot Study
ERIC Educational Resources Information Center
Midford, Richard; Cahill, Helen; Geng, Gretchen; Leckning, Bernard; Robinson, Gary; Te Ava, Aue
2017-01-01
Objective: This pilot study sought to better understand what can be achieved by an evidence-based classroom social and emotional education programme. Design and Methods: A 10-lesson, classroom-based programme that taught about emotional literacy, personal strengths, coping and problem-solving strategies, stress management, emotional regulation and…
Managing Emotion in a Maltreating Context: A Pilot Study Examining Child Neglect
ERIC Educational Resources Information Center
Shipman, Kimberly; Edwards, Anna; Brown, Amy; Swisher, Lisa; Jennings, Ernestine
2005-01-01
Objective: The primary goal of this pilot study was to examine emotion management skills (i.e., emotional understanding, emotion regulation) in children who had experienced neglect and a control group to determine the ways that neglect may interfere with children's emotional development. Method: Participants included children 6-12 years of age and…
ERIC Educational Resources Information Center
Guiberson, Mark; Rodriguez, Barbara L.
2010-01-01
Purpose: To describe the concurrent validity and classification accuracy of 2 Spanish parent surveys of language development, the Spanish Ages and Stages Questionnaire (ASQ; Squires, Potter, & Bricker, 1999) and the Pilot Inventario-III (Pilot INV-III; Guiberson, 2008a). Method: Forty-eight Spanish-speaking parents of preschool-age children…
ERIC Educational Resources Information Center
Boedigheimer, Dan
2010-01-01
Approximately 70% of aviation accidents are attributable to human error. The greatest opportunity for further improving aviation safety is found in reducing human errors in the cockpit. The purpose of this quasi-experimental, mixed-method research was to evaluate whether there was a difference in pilot attitudes toward reducing human error in the…
ERIC Educational Resources Information Center
Anggraini, Purwati; Kusniarti, Tuti
2016-01-01
This study aimed at constructing character education model implemented in primary school. The research method was qualitative with five samples in total, comprising primary schools in Malang city/regency and one school as a pilot model. The pilot model was instructed by theatre coach teacher, parents, and school society. The result showed that…
ERIC Educational Resources Information Center
Koh, Kyungwon; Rubenstein, Ellen; White, Kelvin
2015-01-01
Introduction: This pilot study examined how current information behaviour research addresses the implications and potential impacts of its findings. The goal was to understand what implications and contributions the field has made and how effectively authors communicate implications of their findings. Methods: We conducted a content analysis of 30…
ERIC Educational Resources Information Center
Stefansson, Lilja S.; Webb, M. Elizabeth; Hebert, Luciana E.; Masinter, Lisa; Gilliam, Melissa L.
2018-01-01
Background: Adolescents experience numerous barriers to obtaining sexual and reproductive health care (SRHC). Mobile Health Units (MHUs) can remove some barriers by traveling to the community. This pilot study developed Mobile SRHC through an iterative process on an existing MHU and evaluated it among adolescents and providers. Methods: Mobile…
ERIC Educational Resources Information Center
Daniels, Elizabeth A.; Sherman, Aurora M.
2016-01-01
Using an experimental methodology, the present study investigated adolescents' attitudes toward media images of women in non-appearance-focused (CEO and military pilot) and appearance-focused occupations (model and actor). One hundred adolescent girls and 76 adolescent boys provided ratings of likability, competence, and similarity to self after…
ERIC Educational Resources Information Center
Kovacs, Maria; Sherrill, Joel; George, Charles J.; Pollock, Myrna; Tumuluru, Rameshwari V.; Ho, Vincent
2006-01-01
Objective: To pilot test the acceptability and efficacy of contextual emotion-regulation therapy (CERT), a new, developmentally appropriate intervention for childhood depression, which focuses on the self-regulation of dysphoria. Method: Two samples of convenience (n = 29, n = 2) served to verify some CERT constructs; it was then operationalized…
Pilot Evaluation of Parent and Child Enhancement Program for Disadvantaged Families
ERIC Educational Resources Information Center
Leung, Cynthia; Tsang, Sandra; Leung, Iona
2014-01-01
Objective: The present study was a pilot evaluation of the effectiveness of the Parent and Child Enhancement (PACE) program in enhancing child development for disadvantaged families with children aged 2 to 3. Method: Participants included 23 parent-child dyads who attended 2-hr sessions twice weekly for 20 weeks. Parents and children were assessed…
ERIC Educational Resources Information Center
Sharma, Shreela; Chuang, Ru-Jye; Hedberg, Ann Marie
2011-01-01
Background: The literature on theoretically-based programs targeting healthy nutrition and physical activity in preschools is scarce. Purpose: To pilot test CATCH Early Childhood (CEC), a preschool-based nutrition and physical activity program among children ages three to five in Head Start. Methods: The study was conducted in two Head Start…
ERIC Educational Resources Information Center
Kovach, Jamison V.; Miley, Michelle; Ramos, Miguel A.
2012-01-01
Communication skills are a significant contributor to an individual's success in the workplace. Unfortunately, students often have trouble expressing their ideas in written form and the poor quality of students' written work often impedes the learning process. This pilot study investigates the use of online writing studios within a quality…
Pilot Study for the Active TV Viewer Scholar Education. Final Report. Years 1984-1985.
ERIC Educational Resources Information Center
Torres, Miguel Reyes
The purposes of the "Pilot Study for the Active TV Viewer Scholar Education" project were to find low cost teaching methods that developed critical television viewing skills among elementary and secondary students, and to develop a parallel program of family education in an effort to modify family viewing practices to encourage critical…
Developing Emotional Literacy through Individual Dance Movement Therapy: A Pilot Study
ERIC Educational Resources Information Center
Meekums, Bonnie
2008-01-01
This paper reports a pragmatic mixed methods pilot study of teacher perceptions regarding a school-based Dance Movement therapy (DMT) service for six children aged four to seven in a North of England primary school. No previous studies have systematically evaluated DMT in terms of the development of Emotional Literacy (EL), though theoretical…
Study Skills Analysis: A Pilot Study Linking a Success and Psychology Course
ERIC Educational Resources Information Center
Urciuoli, Jannette Alejandra; Bluestone, Cheryl
2013-01-01
This study explored a concept that learning study skills in the context of the content area under study may transfer across courses, multiplying the benefits towards academic success. Methods that have been reported to influence academic growth at the community college level include success courses and applied study skills. In this pilot project…
ERIC Educational Resources Information Center
Potter, Susan C.; Schneider, Doris; Coyle, Karin K.; May, Gary; Robin, Leah; Seymour, Jenna
2011-01-01
Background: During the 2004-2005 school year, the Mississippi Department of Education, Office of Child Nutrition, initiated a pilot program to distribute free fruit and vegetable snacks to students during the school day. This article describes the first-year implementation of the Mississippi Fruit and Vegetable Pilot Program. Methods: The process…
Factors Influencing Hearing Aid Use in the Classroom: A Pilot Study
ERIC Educational Resources Information Center
Gustafson, Samantha J.; Davis, Hilary; Hornsby, Benjamin W. Y.; Bess, Fred H.
2015-01-01
Purpose: This pilot study examined factors influencing classroom hearing aid use in school-age children with hearing loss. Method: The research team visited classrooms of 38 children with mild-to-moderate hearing loss (Grades 1-7) on 2 typical school days, twice per day, to document hearing aid use. In addition, parents reported the number of…
ERIC Educational Resources Information Center
Grote, Nancy K.; Bledsoe, Sarah E.; Swartz, Holly A.; Frank, Ellen
2004-01-01
Objective: To minimize barriers to care, ameliorate antenatal depression, and prevent postpartum depression, we conducted a pilot study to assess the feasibility of providing brief interpersonal psychotherapy (IPT-B) to depressed, pregnant patients on low incomes in an obstetrics and gynecological (OB/GYN) clinic. Method: Twelve pregnant,…
ERIC Educational Resources Information Center
Alma, Manna A.; Groothoff, Johan W.; Melis-Dankers, Bart J. M.; Suurmeijer, Theo P. B. M.; van der Mei, Sijrike F.
2013-01-01
Introduction: The pilot study reported here determined the effectiveness of a multidisciplinary group rehabilitation program, Visually Impaired Elderly Persons Participating (VIPP), on psychosocial functioning. Methods: The single-group pretest-posttest pilot study included 29 persons with visual impairments (aged 55 and older) who were referred…
A Day in the Life of a Psychiatry Resident: A Pilot Qualitative Analysis
ERIC Educational Resources Information Center
Hilty, Donald M.; Maynes, Sonya M.; Kellner, Maria; Clark, Marilyn S.; Bourgeois, James A.; Servis, Mark E.
2005-01-01
Objective: The topic "A Day in the Life of a Psychiatry Resident" is an opportunity to explore residents' experiences to inform the delivery of education. Methods: An open-ended, qualitative approach was used in a pilot project to explore contemporary residents' experiences with education, similar to a patient-centered model of health care.…
Fixation of radioactive ions in porous media with ion exchange gels
Mercer, Jr., Basil W.; Godfrey, Wesley L.
1979-01-01
A method is provided for fixing radioactive ions in porous media by injecting into the porous media water-soluble organic monomers which are polymerizable to gel structures with ion exchange sites and polymerizing the monomers to form ion exchange gels. The ions and the particles of the porous media are thereby physically fixed in place by the gel structure and, in addition, the ions are chemically fixed by the ion exchange properties of the resulting gel.
Dual mode ion mobility spectrometer and method for ion mobility spectrometry
Scott, Jill R [Idaho Falls, ID; Dahl, David A [Idaho Falls, ID; Miller, Carla J [Idaho Falls, ID; Tremblay, Paul L [Idaho Falls, ID; McJunkin, Timothy R [Idaho Falls, ID
2007-08-21
Ion mobility spectrometer apparatus may include an ion interface that is operable to hold positive and negative ions and to simultaneously release positive and negative ions through respective positive and negative ion ports. A first drift chamber is operatively associated with the positive ion port of the ion interface and encloses an electric field therein. A first ion detector operatively associated with the first drift chamber detects positive ions from the first drift chamber. A second drift chamber is operatively associated with the negative ion port of the ion interface and encloses an electric field therein. A second ion detector operatively associated with the second drift chamber detects negative ions from said second drift chamber.