Sample records for pilot pet study

  1. Monitoring early response to taxane therapy in advanced breast cancer with circulating tumor cells and [(18)F] 3´-deoxy-3´-fluorothymidine PET: a pilot study.

    PubMed

    Contractor, Kaiyumars; Aboagye, Eric O; Jacob, Jimmy; Challapalli, Amarnath; Coombes, R Charles; Stebbing, Justin

    2012-04-01

    Early markers of response to chemotherapy, measured by blood markers and imaging, may ultimately lead to tailored therapies that avoid cumulative toxicity. We performed a small pilot study to compare early changes in levels of circulatory tumor cells (CTCs) with changes in tumor proliferation, using metabolic imaging with [(18)F] 3´-deoxy-3´-fluorothymidine PET (FLT-PET) in women with advanced breast cancer, before and during docetaxel therapy. In those individuals in whom we could detect CTCs, a decrease in CTC count correlated with a decrease in FLT-PET signal, within 2 weeks. Combined, these two technologies are likely to provide a powerful, albeit expensive, tool to assess immediate responses to therapy.

  2. PILOT STUDY OF THE POTENTIAL FOR HUMAN EXPOSURES TO PET-BORNE DIAZINON RESIDUES FOLLOWING LAWN APPLICATIONS IN NORTH CAROLINA

    EPA Science Inventory

    This study examined the potential for indoor/outdoor pet dogs to be an important pathway for transporting diazinon residues into homes and onto occupants following residential lawn applications. The primary objective was to investigate the potential exposures of children and thei...

  3. Separation of packaging plastics by froth flotation in a continuous pilot plant.

    PubMed

    Carvalho, Teresa; Durão, Fernando; Ferreira, Célia

    2010-11-01

    The objective of the research was to apply froth flotation to separate post-consumer PET (Polyethylene Terephthalate) from other packaging plastics with similar density, in a continuously operated pilot plant. A representative sample composed of 85% PET, 2.5% PVC (Polyvinyl Chloride) and 11.9% PS (Polystyrene) was subjected to a combination of alkaline treatment and surfactant adsorption followed by froth flotation. A mineral processing pilot plant, owned by a Portuguese mining company, was adapted for this purpose. The experimentation showed that it is possible to produce an almost pure concentrate of PET, containing 83% of the PET in feed, in a single bank of mechanical flotation cells. The concentrate grade attained was 97.2% PET, 1.1% PVC and 1.1% PS. By simulation it was shown that the Portuguese recycling industry specifications can be attained if one cleaning and one scavenger stages are added to the circuit. Copyright © 2010 Elsevier Ltd. All rights reserved.

  4. One Health in Practice: A Pilot Project for Integrated Care of Zoonotic Infections in Immunocompromised Children and Their Pets in Chile.

    PubMed

    Peña, A; Abarca, K; Weitzel, T; Gallegos, J; Cerda, J; García, P; López, J

    2016-08-01

    Although pets provide physiological and psychological benefits to their owners, they are a potential source of zoonotic infections, especially for vulnerable individuals such as immunocompromised patients. During 1 year, we therefore performed a pilot project, which included 32 immunocompromised Chilean children and their family pets (35 dogs and 9 cats) with the aim of detecting, treating and preventing zoonotic infections. Children were examined by Infectious Diseases paediatricians and demographical and clinical information related to zoonotic infections were recorded. Pets were examined and sampled by veterinarians, who also administered missing routine vaccines and anti-parasitics. During family visits, all members were informed and educated about zoonoses and a satisfaction survey was performed. Visits also included vector control and indoor residual spraying with pyrethroids. Children were re-examined and re-tested according to the findings of their pets, and all detected zoonotic infections were treated both in children and pets. Physical examination revealed abnormalities in 18 dogs (51.4%) and three cats (33.3%). Twenty-eight (63.6%) of the pets were diagnosed with a zoonotic pathogen, and seven (15.9%) with a facultative pathogen. Most zoonotic agents were isolated from the pet's external ear and intestine. Bacteria with the highest pathogenic potential were Campylobacter jejuni and Brucella canis. In two children and their respective pets, the same zoonotic diseases were diagnosed (toxocariasis and giardiasis). Arthropods serving as potential vectors of zoonotic infections were found in 49% of dogs and 44% of cats. The pilot project was positively evaluated by the participating families. Our pilot project confirmed that pets are reservoir for various zoonotic agents in Chile and that the implementation of an integrated multidisciplinary programme was a valuable tool to prevent, diagnose and treat such zoonotic infections in vulnerable patients such as immunocompromised children. © 2015 Blackwell Verlag GmbH.

  5. Pilot biomonitoring of adults and children following use of chlorpyrifos shampoo and flea collars on dogs.

    PubMed

    Dyk, Melinda Bigelow; Chen, Zhenshan; Mosadeghi, Sasan; Vega, Helen; Krieger, Robert

    2011-01-01

    Pesticide handlers and pet owners who use products such as shampoos and dips and insecticide-impregnated collars to treat and control fleas on companion animals are exposed to a variety of active ingredients. Chlorpyrifos exposures of adults and children were measured using urine biomonitoring following use of over-the-counter products on dogs. Age and gender-specific measurements of urinary 3, 5, 6-trichloro-2-pyridinol (TCPy) revealed modest elevations of biomarker excretion following shampoo/dips. Smaller TCPy increments were measured following application of impregnated dog collars. The extent of indoor activity and potential pet contact were important determinants of urine biomarker level. Children without direct pet contact excreted more TCPy following collar application. Pet collars may be a source of indoor surface contamination and human exposure. Children excreted up to 4 times more TCPy than adults when urine volumes were adjusted using age-specific creatinine excretion levels. Although chlorpyrifos is no longer used in the United States in pet care products, results of this research provide perspective on the extent of human exposure from similar pet care products. These pilot studies demonstrated that pet care products such as insecticidal shampoos and dips and impregnated collars may expose family members to low levels of insecticide relative to toxic levels of concern.

  6. The role of respiratory measures to assess mental load in pilot selection.

    PubMed

    Grassmann, Mariel; Vlemincx, Elke; von Leupoldt, Andreas; Van den Bergh, Omer

    2016-06-01

    While cardiovascular measures have a long tradition of being used to determine operator load, responsiveness of the respiratory system to mental load has rarely been investigated. In this study, we assessed basic and variability measures of respiration rate (RR), partial pressure of end-tidal carbon dioxide (petCO2) as well as performance measures in 63 male pilot candidates during completion of a complex cognitive task and subsequent recovery. Mental load was associated with an increase in RR and a decrease in respiratory variability. A significant decrease was also found for petCO2. RR and respiratory variability showed partial and complete effects of recovery, respectively, whereas petCO2 did not return to baseline level. Overall, a good performance was related to a stronger reactivity in RR. Our findings suggest that respiratory parameters would be a useful supplement to common measures for the assessment of mental load in pilot selection. Practitioner Summary: Respiratory measures are a promising yet poorly investigated approach to monitor operator load. For pilot selection, we assessed respiration in response to multitasking in 63 candidates. Task-related changes as well as covariation with performance strongly support the consideration of respiratory parameters when evaluating reactivity to mental load.

  7. What a difference two days make: "personalized" embryo transfer (pET) paradigm: a case report and pilot study.

    PubMed

    Ruiz-Alonso, M; Galindo, N; Pellicer, A; Simón, C

    2014-06-01

    Embryo implantation requires that the blastocyst will attach during the receptive stage of the endometrium, known as window of implantation (WOI). Historically, it has been assumed that the WOI is always constant in all women. However, molecular analyses of endometrial receptivity demonstrates a personalized WOI (pWOI) that is displaced in one out of four patients suffering from recurrent implantation failure (RIF) of endometrial origin and illustrates the utility of a personalized endometrial diagnostic approach. Here, we report a clinical case of successful personalized embryo transfer (pET) after four IVF and three oocyte donation failed attempts in which different embryo transfer strategies were attempted. This case report is complemented by a pilot study of 17 patients undergoing oocyte donation and who suffered failed implantations with routine embryo transfer (ET) but were then treated with pET after the personalized diagnosis of their WOI.

  8. Assessment of glucose metabolism and cellular proliferation in multiple myeloma: a first report on combined 18F-FDG and 18F-FLT PET/CT imaging.

    PubMed

    Sachpekidis, C; Goldschmidt, H; Kopka, K; Kopp-Schneider, A; Dimitrakopoulou-Strauss, A

    2018-04-10

    Despite the significant upgrading in recent years of the role of 18 F-FDG PET/CT in multiple myeloma (MM) diagnostics, there is a still unmet need for myeloma-specific radiotracers. 3'-Deoxy-3'-[ 18 F]fluorothymidine ( 18 F-FLT) is the most studied cellular proliferation PET agent, considered a potentially new myeloma functional imaging tracer. The aim of this pilot study was to evaluate 18 F-FLT PET/CT in imaging of MM patients, in the context of its combined use with 18 F-FDG PET/CT. Eight patients, four suffering from symptomatic MM and four suffering from smoldering MM (SMM), were enrolled in the study. All patients underwent 18 F-FDG PET/CT and 18 F-FLT PET/CT imaging by means of static (whole body) and dynamic PET/CT of the lower abdomen and pelvis (dPET/CT) in two consecutive days. The evaluation of PET/CT studies was based on qualitative evaluation, semi-quantitative (SUV) calculation, and quantitative analysis based on two-tissue compartment modeling. 18 F-FDG PET/CT demonstrated focal, 18 F-FDG avid, MM-indicative bone marrow lesions in five patients. In contrary, 18 F-FLT PET/CT showed focal, 18 F-FLT avid, myeloma-indicative lesions in only two patients. In total, 48 18 F-FDG avid, focal, MM-indicative lesions were detected with 18 F-FDG PET/CT, while 17 18 F-FLT avid, focal, MM-indicative lesions were detected with 18 F-FLT PET/CT. The number of myeloma-indicative lesions was significantly higher for 18 F-FDG PET/CT than for 18 F-FLT PET/CT. A common finding was a mismatch of focally increased 18 F-FDG uptake and reduced 18 F-FLT uptake (lower than the surrounding bone marrow). Moreover, 18 F-FLT PET/CT was characterized by high background activity in the bone marrow compartment, further complicating the evaluation of bone marrow lesions. Semi-quantitative evaluation revealed that both SUV mean and SUV max were significantly higher for 18 F-FLT than for 18 F-FDG in both MM lesions and reference tissue. SUV values were higher in MM lesions than in reference bone marrow for both tracers. Despite the limited number of patients analyzed in this pilot study, the first results of the trial indicate that 18 F-FLT does not seem suitable as a single tracer in MM diagnostics. Further studies with a larger patient population are warranted to generalize the herein presented results.

  9. Pilot testing a digital pet avatar for older adults.

    PubMed

    Chi, Nai-Ching; Sparks, Olivia; Lin, Shih-Yin; Lazar, Amanda; Thompson, Hilaire J; Demiris, George

    Social isolation in older adults is a major public health concern. An embodied conversational agent (ECA) has the potential to enhance older adults' social interaction. However, little is known about older adults' experience with an ECA. In this paper, we conducted a pilot study to examine the perceived acceptance and utility of a tablet-based conversational agent in the form of an avatar (termed "digital pet") for older adults. We performed secondary analysis of data collected from a study that employed the use of a digital pet in ten older adults' homes for three months. Most of the participants enjoyed the companionship, entertainment, reminders, and instant assistance from the digital pet. However, participants identified limited conversational ability and technical issues as system challenges. Privacy, dependence, and cost were major concerns. Future applications should maximize the agent's conversational ability and the system's overall usability. Our results can inform future designs of conversational agents for older adults, which need to include older adults as system co-designers to maximize usability and acceptance. Copyright © 2017 Elsevier Inc. All rights reserved.

  10. Surveillance System for Infectious Diseases of Pets, Santiago, Chile

    PubMed Central

    López, Javier; Abarca, Katia; Valenzuela, Berta; Lorca, Lilia; Olea, Andrea; Aguilera, Ximena

    2009-01-01

    Pet diseases may pose risks to human health but are rarely included in surveillance systems. A pilot surveillance system of pet infectious diseases in Santiago, Chile, found that 4 canine and 3 feline diseases accounted for 90.1% and 98.4% of notifications, respectively. Data also suggested association between poverty and pet diseases. PMID:19861073

  11. New diagnostic pathways urgently needed. Protocol of PET Guidance I pilot study: positron emission tomography in suspected cardiac implantable electronic device-related infection.

    PubMed

    Marciniak-Emmons, Marta Barbara; Sterliński, Maciej; Syska, Paweł; Maciąg, Aleksander; Farkowski, Michał Mirosław; Firek, Bohdan; Dziuk, Mirosław; Zając, Dariusz; Pytkowski, Mariusz; Szwed, Hanna

    2016-01-01

    Cardiovascular implantable electronic device (CIED) infection is a complication of increasing incidence. We present a protocol of an observational case control clinical trial "Positron Emission Tomography Combined With Computed Tomography (PET CT) in Suspected Cardiac Implantable Electronic Device Infection, a Pilot Study - PET Guidance I" (NCT02196753). The aim of this observational clinical trial is to assess and standardise diagnostic algorithms for CIED infections (lead-dependent infective endocarditis, generator pocket infection, fever of unknown origin) with PET CT in Poland. Study group will consist of 20 patients with initial diagnosis of CIED-related infection paired with a control group of 20 patients with implanted CIEDs, who underwent PET CT due to other non-infectious indications and have no data for infectious process in follow-up. All patients included in the study will undergo standard diagnostic pro-cess. Conventional/standard diagnostic and therapeutic process will consist of: medical interview, physical examination, laboratory tests, blood cultures; imaging studies: echocardiography: transthoracic (TTE), and, if there are no contraindications transoesophageal, computed tomography scan for pulmonary embolism if indicated; if there are abnormalities in other systems, decisions concerning further diagnostics will be made at the physician's discretion. As well as standard diagnostic procedures, patients will undergo whole body PET CT scan to localise infection or inflammation. Diagnosis and therapeutic decision will be obtained from the Study Committee. Follow-up will be held within six months with control visits at three and six months. During each follow-up visit, all patients will undergo laboratory tests, two blood cultures collected 1 h apart, and TTE. In case of actual clinical suspicion of infective endocarditis or local generator pocket infection, patients will be referred for further diagnostics. Endpoints for the results assessment - primary endpoints are to standardise PET CT in the diagnostic process: sensitivity, specificity, positive predictive value, and negative predictive value of the diagnosis made by PET CT; secondary endpoints are: assessment of usefulness of PET CT for detection of remote infective complications (metastatic abscesses, infected pulmonary emboli), incidence of particular localisations of infection, influence of PET CT on therapeutic decision: confirmation or change of decision based on PET CT, safety and complications of diagnostic process of CIED-related infections with PET CT. Evaluation of PET CT use for device-related infections in a case control study may be conclusive and improve diagnostic pathway.

  12. The importance of a supportive environment in clinical audit: a pilot study of doctors' engagement with the NHS National PET-CT audit programme.

    PubMed

    Ross, Peter; Hubert, Jane; Saunders, Mike; Wong, Wai Lup

    2014-10-01

    The NHS National PET-CT Audit Programme was launched in 2008 as part of a national NHS programme to widen patient access to PET-computed tomography (CT) imaging in England. However, to implement clinical audit effectively, healthcare professionals need to be fully engaged with the process. The purpose of the pilot study was to identify and explore the different factors that influence doctors' engagement with the National NHS PET-CT Audit Programme. A single embedded case study was undertaken, which centred on the NHS National PET-CT Audit Programme. Seven theoretical propositions drawn from a review of the literature were tested and their influence evaluated. A purposeful sample of 13 semistructured interviews with consultant doctors was taken from different hospitals over a 6-month period. The data were analysed using directed thematic content analysis, with the themes compared against the study's propositions. Doctors' perspectives of clinical audit changed in response to the way in which the audit was implemented. The main barriers to engagement were the lack of a common vision and poor communication, which contributed to poor interprofessional relationships and a perceived culture of blame. In contrast, factors that facilitated engagement centred on the adoption of a more supportive and collaborative approach, which in turn facilitated higher levels of trust between professionals. The dissemination of performance data was found to be a key influencing factor. The study makes use of a unique data set and to the best of our knowledge is one of the first studies to document how the dissemination of doctors' performance data positively influences engagement with clinical audit in England. In addition, the study also shows how, contrary to some studies in the literature, clinical audit can reduce professional anxiety by providing a validation of professional competence. The study supports the premise that clinical audit will be fully embraced by doctors only if they are sufficiently involved in the process so as to be able to redefine and clarify its purpose and meaning. The preliminary findings of this pilot study provide the theoretical underpinning for a national survey into reporter perspectives of the National PET-CT Audit Programme.

  13. Small Pilot Survey on Parents’ Perception of the Relationship between Children and Pets

    PubMed Central

    Russo, Natalia; Vergnano, Diana; Bergero, Domenico

    2017-01-01

    Since companion animals are taking on more important roles in family life, the aim of this study was to evaluate the perception of parents about the relationship between their children and pets. A number of parents were asked to fill in a questionnaire; the principal topics were: pet ownership, pet care, relationship between pets and children, and sources of information about pet management. Eighty-two parents completed the survey; 71.4% of them already had pets before having children; pet care and health has emerged to be rather important, since 96.4% of the pets are taken to the veterinarian at least once a year; moreover, the great majority of the parents (97.2%) were not worried about the possible risks, linked to pets, pertaining to their child’s health. The present survey confirms that pets are mostly considered as members of the family, and not only as a benefit for the children. Moreover, the relationship between children and pets is basically seen as a positive experience for children. PMID:29056710

  14. Relationship between sources of pet acquisition and euthanasia of cats and dogs in an animal shelter: a pilot study.

    PubMed

    Arbe Montoya, A I; Rand, J S; Greer, R M; Alberthsen, C; Vankan, D

    2017-06-01

    Approximately 140,000 unwanted dogs and cats are culled in Australia annually. There is a paucity of information linking sources of pet acquisition with subsequent euthanasia, which may inform evidence-based strategies to reduce euthanasia rates. This pilot study aimed to determine whether there is a higher risk of euthanasia related to the source of acquisition for pets surrendered to an animal shelter. Data for 5391 dogs and 5581 cats surrendered to one Queensland shelter between January 2006 and December 2009 were analysed. The main sources of acquisition for owner-surrendered dogs were 'shelter' and 'pet shop' and for owner-surrendered cats were 'own litter' and 'shelter'. Euthanasia rates for different sources varied. For adult dogs, acquisition through newspaper advertisements was associated with the highest euthanasia rate. Adult cats obtained as gifts (from friend or family member) had the highest euthanasia rate. For junior cats, the overwhelming source was the owner's own litter (68% of intake) and only kittens acquired as strays were at significantly higher risk of euthanasia. For both dogs and cats, animals acquired from shelters had lower rates of euthanasia than most other sources, which suggests that shelter-sourced animals may be considered a preferred source for pet acquisition to assist in reducing the number of adoptable pets euthanased. There was evidence from the study animal shelter that the risk of euthanasia was related to acquisition source. These findings should be confirmed by prospective studies, which should also investigate the interaction between acquisition source and other factors, using larger data sets from a variety of shelters. © 2017 Australian Veterinary Association.

  15. A first-in-man study of 68Ga-nanocolloid PET-CT sentinel lymph node imaging in prostate cancer demonstrates aberrant lymphatic drainage pathways.

    PubMed

    Doughton, Jacki A; Hofman, Michael S; Eu, Peter; Hicks, Rodney J; Williams, Scott G

    2018-05-04

    Purpose: To assess feasibility, safety and utility of a novel 68 Ga-nanocolloid radio-tracer with PET-CT lymphoscintigraphy for identification of sentinel lymph nodes (SLN). Methods: Pilot study of patients from a tertiary cancer hospital who required insertion of gold fiducials for prostate cancer radiation therapy. Participation did not affect cancer management. Ultrasound-guided transperineal intra-prostatic injection of PET tracer (iron oxide nanocolloid labelled with gallium-68) after placement of fiducials. PET-CT lymphoscintigraphy imaging at approximately 45 and 100 minutes after in-jection of tracer. The study was monitored using Bayesian trial design with the as-sumption that at least one sentinel lymph node (SLN) could be identified in at least two-thirds of cases with >80% confidence. Results: SLN identification was successful in all 5 participants, allowing completion of the pilot study as per protocol. No adverse effects were observed. Unexpected po-tential pathways for transit of malignant cells as well as expected regional drainage pathways were discovered. Rapid tracer drainage to pelvic bone, perivesical, mesorec-tal, inguinal and Virchow's nodes was identified. Conclusion: SLN identification using 68 Ga-nanocolloid PET-CT can be successfully performed. Non-traditional pathways of disease spread were identified including drainage to pelvic bone as well as perivesical, mesorectal, inguinal and Virchow's nodes. Prevalence of both aberrant and non-lymphatic pathways of spread should be further investigated with this technique. Copyright © 2018 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  16. Robot-assisted therapy for improving social interactions and activity participation among institutionalized older adults: a pilot study.

    PubMed

    Sung, Huei-Chuan; Chang, Shu-Min; Chin, Mau-Yu; Lee, Wen-Li

    2015-03-01

    Animal-assisted therapy is gaining popularity as part of therapeutic activities for older adults in many long-term care facilities. However, concerns about dog bites, allergic responses to pets, disease, and insufficient available resources to care for a real pet have led to many residential care facilities to ban this therapy. There are situations where a substitute artificial companion, such as robotic pet, may serve as a better alternative. This pilot study used a one-group pre- and posttest design to evaluate the effect of a robot-assisted therapy for older adults. Sixteen eligible participants participated in the study and received a group robot-assisted therapy using a seal-like robot pet for 30 minutes twice a week for 4 weeks. All participants received assessments of their communication and interaction skills using the Assessment of Communication and Interaction Skills (ACIS-C) and activity participation using the Activity Participation Scale at baseline and at week 4. A total of 12 participants completed the study. Wilcoxon signed rank test showed that participants' communication and interaction skills (z = -2.94, P = 0.003) and activity participation (z = -2.66, P = 0.008) were significantly improved after receiving 4-week robot-assisted therapy. By interacting with a robot pet, such as Paro, the communication, interaction skills, and activity participation of the older adults can be improved. The robot-assisted therapy can be provided as a routine activity program and has the potential to improve social health of older adults in residential care facilities. Copyright © 2014 Wiley Publishing Asia Pty Ltd.

  17. Asking About Pets Enhances Patient Communication and Care: A Pilot Study.

    PubMed

    Hodgson, Kate; Darling, Marcia; Freeman, Douglas; Monavvari, Alan

    2017-01-01

    This research explored whether asking patients about their pets would enable better environmental/social history taking, and improve patient communication/care. Primary health care providers (PHPs) were surveyed about prevalence of patients living with pets, the health impact of pets, and influences on patient communication. Following an educational intervention, they committed to asking patients about their pets. A follow-up survey was conducted electronically. PHPs were recruited at a continuing medical education (CME) conference and at CME workshops. All 225 participants were PHPs. At the conference, participants were educated one-on-one about the clinical relevance of pets in the family. CME sessions were large or small group teaching. Baseline and final surveys measured awareness of pets in patients' families, assessment of determinants of health, impact on rapport with patients, and patient care. A sign test assessed difference in scores using repeated-measures analysis. Binomial outcomes were assessed using Fisher's exact test. Comments were themed. Ninety-four PHPs (42%) completed the study. Pet-related discussions opened communication with patients. Two-thirds of participants identified positive effects on practice and on relationships with patients. PHPs were able to leverage the health benefits of pets (zooeyia) and mitigate zoonotic risk. Asking patients about pets in the family reveals clinically relevant information, improves communication, and strengthens the therapeutic alliance.

  18. Asking About Pets Enhances Patient Communication and Care: A Pilot Study

    PubMed Central

    Hodgson, Kate; Darling, Marcia; Freeman, Douglas; Monavvari, Alan

    2017-01-01

    This research explored whether asking patients about their pets would enable better environmental/social history taking, and improve patient communication/care. Primary health care providers (PHPs) were surveyed about prevalence of patients living with pets, the health impact of pets, and influences on patient communication. Following an educational intervention, they committed to asking patients about their pets. A follow-up survey was conducted electronically. PHPs were recruited at a continuing medical education (CME) conference and at CME workshops. All 225 participants were PHPs. At the conference, participants were educated one-on-one about the clinical relevance of pets in the family. CME sessions were large or small group teaching. Baseline and final surveys measured awareness of pets in patients’ families, assessment of determinants of health, impact on rapport with patients, and patient care. A sign test assessed difference in scores using repeated-measures analysis. Binomial outcomes were assessed using Fisher’s exact test. Comments were themed. Ninety-four PHPs (42%) completed the study. Pet-related discussions opened communication with patients. Two-thirds of participants identified positive effects on practice and on relationships with patients. PHPs were able to leverage the health benefits of pets (zooeyia) and mitigate zoonotic risk. Asking patients about pets in the family reveals clinically relevant information, improves communication, and strengthens the therapeutic alliance. PMID:28984509

  19. Simultaneous 68Ga-DOTATOC PET/MRI in patients with gastroenteropancreatic neuroendocrine tumors: initial results.

    PubMed

    Beiderwellen, Karsten J; Poeppel, Thorsten D; Hartung-Knemeyer, Verena; Buchbender, Christian; Kuehl, Hilmar; Bockisch, Andreas; Lauenstein, Thomas C

    2013-05-01

    The aim of this pilot study was to demonstrate the potential of simultaneously acquired 68-Gallium-DOTA-D-Phe1-Tyr3-octreotide (68Ga-DOTATOC) positron emission tomography/magnetic resonance imaging (PET/MRI) in comparison with 68Ga-DOTATOC PET/computed tomography (PET/CT) in patients with known gastroenteropancreatic neuroendocrine tumors (NETs). Eight patients (4 women and 4 men; mean [SD] age, 54 [17] years; median, 55 years; range 25-74 years) with histopathologically confirmed NET and scheduled 68Ga-DOTATOC PET/CT were prospectively enrolled for an additional integrated PET/MRI scan. Positron emission tomography/computed tomography was performed using a triple-phase contrast-enhanced full-dose protocol. Positron emission tomography/magnetic resonance imaging encompassed a diagnostic, contrast-enhanced whole-body MRI protocol. Two readers separately analyzed the PET/CT and PET/MRI data sets including their subscans in random order regarding lesion localization, count, and characterization on a 4-point ordinal scale (0, not visible; 1, benign; 2, indeterminate; and 3, malignant). In addition, each lesion was rated in consensus on a binary scale (allowing for benign/malignant only). Clinical imaging, existing prior examinations, and histopathology (if available) served as the standard of reference. In PET-positive lesions, the standardized uptake value (SUV max) was measured in consensus. A descriptive, case-oriented data analysis was performed, including determination of frequencies and percentages in detection of malignant, benign, and indeterminate lesions in connection to their localization. In addition, percentages in detection by a singular modality (such as PET, CT, or MRI) were calculated. Interobserver variability was calculated (Cohen's κ). The SUVs in the lesions in PET/CT and PET/MRI were measured, and the correlation coefficient (Pearson, 2-tailed) was calculated. According to the reference standard, 5 of the 8 patients had malignant NET lesions at the time of the examination. A total of 4 patients were correctly identified by PET/CT, with the PET and CT component correctly identifying 3 patients each. All 5 patients positive for NET disease were correctly identified by PET/MRI, with the MRI subscan identifying all 5 patients and the PET subscan identifying 3 patients. All lesions considered as malignant in PET/CT were equally depicted in and considered using PET/MRI. One liver lesion rated as "indetermined" in PET/CT was identified as metastasis in PET/MRI because of a diffusion restriction in diffusion-weighted imaging. Of the 4 lung lesions characterized in PET/CT, only 1 was depicted in PET/MRI. Of the 3 lymph nodes depicted in PET/CT, only 1 was characterized in PET/MRI. Interobserver reliability was equally very good in PET/CT (κ = 0.916) and PET/MRI (κ = 1.0). The SUV max measured in PET/CT and in PET/MRI showed a strong correlation (Pearson correlation coefficient, 0.996). This pilot study demonstrates the potential of 68Ga-DOTATOC PET/MRI in patients with gastroenteropancreatic NET, with special advantages in the characterization of abdominal lesions yet certain weaknesses inherent to MRI, such as lung metastases and hypersclerotic bone lesions.

  20. Pilot study utilizing Fluorine-18 fluorodeoxyglucose-positron emission tomography/computed tomography for glycolytic phenotyping of canine mast cell tumors.

    PubMed

    Griffin, Lynn R; Thamm, Doug H; Selmic, Laura E; Ehrhart, E J; Randall, Elissa

    2018-03-23

    The goal of this prospective pilot study was to use naturally occurring canine mast cell tumors of various grades and stages as a model for attempting to determine how glucose uptake and markers of biologic behavior are correlated. It was hypothesized that enhanced glucose uptake, as measured by 2-[fluorine-18]fluoro-d-glucose-positron emission tomography/computed tomography (F18 FDG PET-CT), would correlate with histologic grade. Dogs were recruited for this study from a population referred for treatment of cytologically or histologically confirmed mast cell tumors. Patients were staged utilizing standard of care methods (abdominal ultrasound and three view thoracic radiographs), followed by a whole body F18 FDG PET-CT. Results of the F18 FDG PET-CT were analyzed for possible metastasis and standard uptake value maximum (SUV max ) of identified lesions. Incisional or excisional biopsies of the accessible mast cell tumors were obtained and histology performed. Results were then analyzed to look for a possible correlation between the grade of mast cell tumors and SUV max . A total of nine animals were included in the sample. Findings indicated that there was a correlation between grade of mast cell tumors and SUV max as determined by F18 FDG PET-CT (p-value = 0.073, significance ≤ 0.1). Based on the limited power of this study, it is felt that further research to examine the relationship between glucose utilization and biologic aggressiveness in canine mast cell tumors is warranted. This study was unable to show that F18 FDG PET-CT was a better staging tool than standard of care methods. © 2018 American College of Veterinary Radiology.

  1. Therapeutic robocat for nursing home residents with dementia: preliminary inquiry.

    PubMed

    Libin, Alexander; Cohen-Mansfield, Jiska

    2004-01-01

    Traditional pet therapy enhances individual well-being. However, there are situations where a substitute artificial companion (i.e., robotic pet) may serve as a better alternative because of insufficient available resources to care for a real pet, allergic responses to pets, or other difficulties. This pilot study, which compared the benefits of a robotic cat and a plush toy cat as interventions for elderly persons with dementia, was conducted at a special care unit of a large, not-for-profit nursing home. Various aspects of a person's engagement and affect were assessed through direct observations. Though not identical, similar trends were seen for the two cats. Interacting with the cats was linked with decreased agitation and increased pleasure and interest. The study is intended to pave the way for future research on robotherapy with nursing home residents.

  2. The benefit of pets and animal-assisted therapy to the health of older individuals.

    PubMed

    Cherniack, E Paul; Cherniack, Ariella R

    2014-01-01

    Many studies utilizing dogs, cats, birds, fish, and robotic simulations of animals have tried to ascertain the health benefits of pet ownership or animal-assisted therapy in the elderly. Several small unblinded investigations outlined improvements in behavior in demented persons given treatment in the presence of animals. Studies piloting the use of animals in the treatment of depression and schizophrenia have yielded mixed results. Animals may provide intangible benefits to the mental health of older persons, such as relief social isolation and boredom, but these have not been formally studied. Several investigations of the effect of pets on physical health suggest animals can lower blood pressure, and dog walkers partake in more physical activity. Dog walking, in epidemiological studies and few preliminary trials, is associated with lower complication risk among patients with cardiovascular disease. Pets may also have harms: they may be expensive to care for, and their owners are more likely to fall. Theoretically, zoonotic infections and bites can occur, but how often this occurs in the context of pet ownership or animal-assisted therapy is unknown. Despite the poor methodological quality of pet research after decades of study, pet ownership and animal-assisted therapy are likely to continue due to positive subjective feelings many people have toward animals.

  3. The Benefit of Pets and Animal-Assisted Therapy to the Health of Older Individuals

    PubMed Central

    Cherniack, E. Paul; Cherniack, Ariella R.

    2014-01-01

    Many studies utilizing dogs, cats, birds, fish, and robotic simulations of animals have tried to ascertain the health benefits of pet ownership or animal-assisted therapy in the elderly. Several small unblinded investigations outlined improvements in behavior in demented persons given treatment in the presence of animals. Studies piloting the use of animals in the treatment of depression and schizophrenia have yielded mixed results. Animals may provide intangible benefits to the mental health of older persons, such as relief social isolation and boredom, but these have not been formally studied. Several investigations of the effect of pets on physical health suggest animals can lower blood pressure, and dog walkers partake in more physical activity. Dog walking, in epidemiological studies and few preliminary trials, is associated with lower complication risk among patients with cardiovascular disease. Pets may also have harms: they may be expensive to care for, and their owners are more likely to fall. Theoretically, zoonotic infections and bites can occur, but how often this occurs in the context of pet ownership or animal-assisted therapy is unknown. Despite the poor methodological quality of pet research after decades of study, pet ownership and animal-assisted therapy are likely to continue due to positive subjective feelings many people have toward animals. PMID:25477957

  4. Integrated telemedicine applications and services for oncological positron emission tomography.

    PubMed

    Kontaxakis, George; Visvikis, Dimitris; Ohl, Roland; Sachpazidis, Ilias; Suarez, Juan Pablo; Selby, Peter; Cheze-Le Rest, Catherine; Santos, Andres; Ortega, Fernando; Diaz, Javier; Pan, Leyun; Strauss, Ludwig; Dimitrakopoulou-Strauss, Antonia; Sakas, Georgios; Pozo, Miguel Angel

    2006-01-01

    TENPET (Trans European Network for Positron Emission Tomography) aims to evaluate the provision of integrated teleconsultation and intelligent computer supported cooperative work services for clinical positron emission tomography (PET) in Europe at its current stage, as it is a multi-centre project financially supported by the European Commission (Information Society, eTEN Program). It addresses technological challenges by linking PET centres and developing supporting services that permit remote consultation between professionals in the field. The technological platform (CE-marked) runs on Win2000/NT/XP systems and incorporates advanced techniques for image visualization, analysis and fusion, as well as for interactive communication and message handling for off-line communications. Four PET Centres from Spain, France and Germany participate to the pilot system trials. The performance evaluation of the system is carried out via log files and user-filled questionnaires on the frequency of the teleconsultations, their duration and efficacy, quality of the images received, user satisfaction, as well as on privacy, ethical and security issues. TENPET promotes the co-operation and improved communication between PET practitioners that are miles away from their peers or on mobile units, offering options for second opinion and training and permitting physicians to remotely consult patient data if they are away from their centre. It is expected that TENPET will have a significant impact in the development of new skills by PET professionals and will support the establishment of peripheral PET units. To our knowledge, TENPET is the first telemedicine service specifically designed for oncological PET. This report presents the technical innovations incorporated in the TENPET platform and the initial pilot studies at real and diverse clinical environments in the field of oncology.

  5. Radiotherapy volume delineation using dynamic [18F]-FDG PET/CT imaging in patients with oropharyngeal cancer: a pilot study.

    PubMed

    Silvoniemi, Antti; Din, Mueez U; Suilamo, Sami; Shepherd, Tony; Minn, Heikki

    2016-11-01

    Delineation of gross tumour volume in 3D is a critical step in the radiotherapy (RT) treatment planning for oropharyngeal cancer (OPC). Static [ 18 F]-FDG PET/CT imaging has been suggested as a method to improve the reproducibility of tumour delineation, but it suffers from low specificity. We undertook this pilot study in which dynamic features in time-activity curves (TACs) of [ 18 F]-FDG PET/CT images were applied to help the discrimination of tumour from inflammation and adjacent normal tissue. Five patients with OPC underwent dynamic [ 18 F]-FDG PET/CT imaging in treatment position. Voxel-by-voxel analysis was performed to evaluate seven dynamic features developed with the knowledge of differences in glucose metabolism in different tissue types and visual inspection of TACs. The Gaussian mixture model and K-means algorithms were used to evaluate the performance of the dynamic features in discriminating tumour voxels compared to the performance of standardized uptake values obtained from static imaging. Some dynamic features showed a trend towards discrimination of different metabolic areas but lack of consistency means that clinical application is not recommended based on these results alone. Impact of inflammatory tissue remains a problem for volume delineation in RT of OPC, but a simple dynamic imaging protocol proved practicable and enabled simple data analysis techniques that show promise for complementing the information in static uptake values.

  6. Cobalt-55 positron emission tomography in traumatic brain injury: a pilot study.

    PubMed Central

    Jansen, H M; van der Naalt, J; van Zomeren, A H; Paans, A M; Veenma-van der Duin, L; Hew, J M; Pruim, J; Minderhoud, J M; Korf, J

    1996-01-01

    Traumatic brain injury is usually assessed with the Glasgow coma scale (GCS), CT, or MRI. After such injury, the injured brain tissue is characterised by calcium mediated neuronal damage and inflammation. Positron emission tomography with the isotope cobalt-55 (Co-PET) as a calcium tracer enables imaging of affected tissue in traumatic brain injury. The aim was to determine whether additional information can be gained by Co-PET in the diagnosis of moderate traumatic brain injury and to assess any prognostic value of Co-PET. Five patients with recent moderately severe traumatic brain injury were studied. CT was performed on the day of admission, EEG within one week, and MRI and Co-PET within four weeks of injury. Clinical assessment included neurological examination, GCS, neuropsychological testing, and Glasgow outcome scale (GOS) after one year. Co-PET showed focal uptake that extended beyond the morphological abnormalities shown by MRI and CT, in brain regions that were actually diagnosed with EEG. Thus Co-PET is potentially useful for diagnostic localisation of both structural and functional abnormalities in moderate traumatic brain injury. Images PMID:8708661

  7. F-18 sodium fluoride PET/CT does not effectively image myocardial inflammation due to suspected cardiac sarcoidosis.

    PubMed

    Weinberg, Richard L; Morgenstern, Rachelle; DeLuca, Albert; Chen, Jennifer; Bokhari, Sabahat

    2017-12-01

    Sarcoidosis is an inflammatory disorder of unknown etiology that can involve the heart. While effective in imaging cardiac sarcoidosis, F-18 fluorodeoxyglucose (FDG) PET/CT often shows non-specific myocardial uptake. F-18 sodium fluoride (NaF) has been used to image inflammation in coronary artery plaques and has low background myocardial uptake. Here, we evaluated whether F-18 NaF can image myocardial inflammation due to clinically suspected cardiac sarcoidosis. We performed a single institution pilot study testing if F-18 NaF PET/CT can detect myocardial inflammation in patients with suspected cardiac sarcoidosis. Patients underwent cardiac PET/CT with F-18 FDG as part of their routine care and subsequently received an F-18 NaF PET/CT scan. Three patients underwent F-18 FDG and F-18 NaF imaging. In all patients, there was F-18 FDG uptake consistent with cardiac sarcoidosis. The F-18 NaF PET/CT scans showed no myocardial uptake. In this small preliminary study, PET/CT scan using F-18 NaF does not appear to detect myocardial inflammation caused by suspected cardiac sarcoidosis.

  8. Florbetapir-PET β-amyloid imaging and associated neuropsychological trajectories in survivors of critical illness: A case series.

    PubMed

    Jackson, James C; Warrington, Hillary J; Kessler, Robert; Kiehl, Amy L; Wesley Ely, E

    2018-04-01

    Cognitive impairment resembling Alzheimer's disease is common in survivors of critical illness. We hypothesized that Intensive Care Unit (ICU) survivors with cognitive impairment would have significant amyloid and designed a pilot study to explore this relationship. A pilot, case series of a convenience sample of 14 adult medical and surgical ICU survivors, in a clinical neuroradiology clinic. Patients underwent cognitive testing at 3months, 1year, 4years, and 6years after hospital discharge with the Repeatable Battery for the Assessment of Neuropsychological Status. They received a single PET scan using amyloid PET imaging (florbetapir F18) 2 to 4years after their ICU stay. Amyloid (defined as a Standard Uptake Value ratio or SUVr >1.10) was present in 2 of 14 (14%) individuals, both of whom demonstrated significant cognitive impairment yet no consistent decline over time. Of the 6 impaired patients (RBANS<78), 4 (66.7%) were amyloid negative. It is feasible to assess ICU survivors with amyloid imaging. In this small sample, most patients with cognitive impairment were negative on amyloid PET imaging, which raises the possibility that ICU survivors may experience a unique form of dementia not driven by an amyloid related mechanism. Copyright © 2017. Published by Elsevier Inc.

  9. Monitoring proton radiation therapy with in-room PET imaging

    NASA Astrophysics Data System (ADS)

    Zhu, Xuping; España, Samuel; Daartz, Juliane; Liebsch, Norbert; Ouyang, Jinsong; Paganetti, Harald; Bortfeld, Thomas R.; El Fakhri, Georges

    2011-07-01

    We used a mobile positron emission tomography (PET) scanner positioned within the proton therapy treatment room to study the feasibility of proton range verification with an in-room, stand-alone PET system, and compared with off-line equivalent studies. Two subjects with adenoid cystic carcinoma were enrolled into a pilot study in which in-room PET scans were acquired in list-mode after a routine fractionated treatment session. The list-mode PET data were reconstructed with different time schemes to generate in-room short, in-room long and off-line equivalent (by skipping coincidences from the first 15 min during the list-mode reconstruction) PET images for comparison in activity distribution patterns. A phantom study was followed to evaluate the accuracy of range verification for different reconstruction time schemes quantitatively. The in-room PET has a higher sensitivity compared to the off-line modality so that the PET acquisition time can be greatly reduced from 30 to <5 min. Features in deep-site, soft-tissue regions were better retained with in-room short PET acquisitions because of the collection of 15O component and lower biological washout. For soft tissue-equivalent material, the distal fall-off edge of an in-room short acquisition is deeper compared to an off-line equivalent scan, indicating a better coverage of the high-dose end of the beam. In-room PET is a promising low cost, high sensitivity modality for the in vivo verification of proton therapy. Better accuracy in Monte Carlo predictions, especially for biological decay modeling, is necessary.

  10. Whole-body biodistribution and brain PET imaging with [18F]AV-45, a novel amyloid imaging agent--a pilot study.

    PubMed

    Lin, Kun-Ju; Hsu, Wen-Chuin; Hsiao, Ing-Tsung; Wey, Shiaw-Pyng; Jin, Lee-Way; Skovronsky, Daniel; Wai, Yau-Yau; Chang, Hsiu-Ping; Lo, Chuan-Wei; Yao, Cheng Hsiang; Yen, Tzu-Chen; Kung, Mei-Ping

    2010-05-01

    The compound (E)-4-(2-(6-(2-(2-(2-(18)F-fluoroethoxy)ethoxy)ethoxy) pyridin-3-yl)vinyl)-N-methylbenzenamine ([(18)F]AV-45) is a novel radiopharmaceutical capable of selectively binding to beta-amyloid (A beta) plaques. This pilot study reports the safety, biodistribution, and radiation dosimetry of [(18)F]AV-45 in human subjects. In vitro autoradiography and fluorescent staining of postmortem brain tissue from patients with Alzheimer's disease (AD) and cognitively healthy subjects were performed to assess the specificity of the tracer. Biodistribution was assessed in three healthy elderly subjects (mean age: 60.0+/-5.2 years) who underwent 3-h whole-body positron emission tomography (PET)/computed tomographic (CT) scans after a bolus injection of 381.9+/-13.9 MBq of [(18)F]AV-45. Another six subjects (three AD patients and three healthy controls, mean age: 67.7+/-13.6 years) underwent brain PET studies. Source organs were delineated on PET/CT. All subjects underwent magnetic resonance imaging (MRI) for obtaining structural information. In vitro autoradiography revealed exquisitely high specific binding of [(18)F]AV-45 to postmortem AD brain sections, but not to the control sections. There were no serious adverse events throughout the study period. The peak uptake of the tracer in the brain was 5.12+/-0.41% of the injected dose. The highest absorbed organ dose was to the gallbladder wall (184.7+/-78.6 microGy/MBq, 4.8 h voiding interval). The effective dose equivalent and effective dose values for [(18)F]AV-45 were 33.8+/-3.4 microSv/MBq and 19.3+/-1.3 microSv/MBq, respectively. [(18)F]AV-45 binds specifically to A beta in vitro, and is a safe PET tracer for studying A beta distribution in human brain. The dosimetry is suitable for clinical and research application. (c) 2010 Elsevier Inc. All rights reserved.

  11. Simultaneous whole-body 18F-PSMA-1007-PET/MRI with integrated high-resolution multiparametric imaging of the prostatic fossa for comprehensive oncological staging of patients with prostate cancer: a pilot study.

    PubMed

    Freitag, Martin T; Kesch, Claudia; Cardinale, Jens; Flechsig, Paul; Floca, Ralf; Eiber, Matthias; Bonekamp, David; Radtke, Jan P; Kratochwil, Clemens; Kopka, Klaus; Hohenfellner, Markus; Stenzinger, Albrecht; Schlemmer, Heinz-Peter; Haberkorn, Uwe; Giesel, Frederik

    2018-03-01

    The aim of the present study was to explore the clinical feasibility and reproducibility of a comprehensive whole-body 18 F-PSMA-1007-PET/MRI protocol for imaging prostate cancer (PC) patients. Eight patients with high-risk biopsy-proven PC underwent a whole-body PET/MRI (3 h p.i.) including a multi-parametric prostate MRI after 18 F-PSMA-1007-PET/CT (1 h p.i.) which served as reference. Seven patients presented with non-treated PC, whereas one patient presented with biochemical recurrence. SUV mean -quantification was performed using a 3D-isocontour volume-of-interest. Imaging data was consulted for TNM-staging and compared with histopathology. PC was confirmed in 4/7 patients additionally by histopathology after surgery. PET-artifacts, co-registration of pelvic PET/MRI and MRI-data were assessed (PI-RADS 2.0). The examinations were well accepted by patients and comprised 1 h. SUV mean -values between PET/CT (1 h p.i.) and PET/MRI (3 h p.i.) were significantly correlated (p < 0.0001, respectively) and similar to literature of 18 F-PSMA-1007-PET/CT 1 h vs 3 h p.i. The dominant intraprostatic lesion could be detected in all seven patients in both PET and MRI. T2c, T3a, T3b and T4 features were detected complimentarily by PET and MRI in five patients. PET/MRI demonstrated moderate photopenic PET-artifacts surrounding liver and kidneys representing high-contrast areas, no PET-artifacts were observed for PET/CT. Simultaneous PET-readout during prostate MRI achieved optimal co-registration results. The presented 18 F-PSMA-1007-PET/MRI protocol combines efficient whole-body assessment with high-resolution co-registered PET/MRI of the prostatic fossa for comprehensive oncological staging of patients with PC.

  12. Enhancing 18F-FDG-PET/CT analysis in lung cancer patients. Is CT-CT image fusion helpful in predicting pleural involvement? A pilot study.

    PubMed

    Kapfhammer, A; Winkens, T; Lesser, T; Reissig, A; Steinert, M; Freesmeyer, M

    2015-01-01

    To retrospectively evaluate the feasibility and value of CT-CT image fusion to assess the shift of peripheral lung cancers with/-out chest wall infiltration, comparing computed tomography acquisitions in shallow-breathing (SB-CT) and deep-inspiration breath-hold (DIBH-CT) in patients undergoing FDG-PET/CT for lung cancer staging. Image fusion of SB-CT and DIBH-CT was performed with a multimodal workstation used for nuclear medicine fusion imaging. The distance of intrathoracic landmarks and the positional shift of tumours were measured using semi-transparent overlay of both CT series. Statistical analyses were adjusted for confounders of tumour infiltration. Cutoff levels were calculated for prediction of no-/infiltration. Lateral pleural recessus and diaphragm showed the largest respiratory excursions. Infiltrating lung cancers showed more limited respiratory shifts than non-infiltrating tumours. A large respiratory tumour-motility accurately predicted non-infiltration. However, the tumour shifts were limited and variable, limiting the accuracy of prediction. This pilot fusion study proved feasible and allowed a simple analysis of the respiratory shifts of peripheral lung tumours using CT-CT image fusion in a PET/CT setting. The calculated cutoffs were useful in predicting the exclusion of chest wall infiltration but did not accurately predict tumour infiltration. This method can provide additional qualitative information in patients with lung cancers with contact to the chest wall but unclear CT evidence of infiltration undergoing PET/CT without the need of additional investigations. Considering the small sample size investigated, further studies are necessary to verify the obtained results.

  13. Quantitative assessment of the physical potential of proton beam range verification with PET/CT.

    PubMed

    Knopf, A; Parodi, K; Paganetti, H; Cascio, E; Bonab, A; Bortfeld, T

    2008-08-07

    A recent clinical pilot study demonstrated the feasibility of offline PET/CT range verification for proton therapy treatments. In vivo PET measurements are challenged by blood perfusion, variations of tissue compositions, patient motion and image co-registration uncertainties. Besides these biological and treatment specific factors, the accuracy of the method is constrained by the underlying physical processes. This phantom study distinguishes physical factors from other factors, assessing the reproducibility, consistency and sensitivity of the PET/CT range verification method. A spread-out Bragg-peak (SOBP) proton field was delivered to a phantom consisting of poly-methyl methacrylate (PMMA), lung and bone equivalent material slabs. PET data were acquired in listmode at a commercial PET/CT scanner available within 10 min walking distance from the proton therapy unit. The measured PET activity distributions were compared to simulations of the PET signal based on Geant4 and FLUKA Monte Carlo (MC) codes. To test the reproducibility of the measured PET signal, data from two independent measurements at the same geometrical position in the phantom were compared. Furthermore, activation depth profiles within identical material arrangements but at different positions within the irradiation field were compared to test the consistency of the measured PET signal. Finally, activation depth profiles through air/lung, air/bone and lung/bone interfaces parallel as well as at 6 degrees to the beam direction were studied to investigate the sensitivity of the PET/CT range verification method. The reproducibility and the consistency of the measured PET signal were found to be of the same order of magnitude. They determine the physical accuracy of the PET measurement to be about 1 mm. However, range discrepancies up to 2.6 mm between two measurements and range variations up to 2.6 mm within one measurement were found at the beam edge and at the edge of the field of view (FOV) of the PET scanner. PET/CT range verification was found to be able to detect small range modifications in the presence of complex tissue inhomogeneities. This study indicates the physical potential of the PET/CT verification method to detect the full-range characteristic of the delivered dose in the patient.

  14. Quantitative assessment of the physical potential of proton beam range verification with PET/CT

    NASA Astrophysics Data System (ADS)

    Knopf, A.; Parodi, K.; Paganetti, H.; Cascio, E.; Bonab, A.; Bortfeld, T.

    2008-08-01

    A recent clinical pilot study demonstrated the feasibility of offline PET/CT range verification for proton therapy treatments. In vivo PET measurements are challenged by blood perfusion, variations of tissue compositions, patient motion and image co-registration uncertainties. Besides these biological and treatment specific factors, the accuracy of the method is constrained by the underlying physical processes. This phantom study distinguishes physical factors from other factors, assessing the reproducibility, consistency and sensitivity of the PET/CT range verification method. A spread-out Bragg-peak (SOBP) proton field was delivered to a phantom consisting of poly-methyl methacrylate (PMMA), lung and bone equivalent material slabs. PET data were acquired in listmode at a commercial PET/CT scanner available within 10 min walking distance from the proton therapy unit. The measured PET activity distributions were compared to simulations of the PET signal based on Geant4 and FLUKA Monte Carlo (MC) codes. To test the reproducibility of the measured PET signal, data from two independent measurements at the same geometrical position in the phantom were compared. Furthermore, activation depth profiles within identical material arrangements but at different positions within the irradiation field were compared to test the consistency of the measured PET signal. Finally, activation depth profiles through air/lung, air/bone and lung/bone interfaces parallel as well as at 6° to the beam direction were studied to investigate the sensitivity of the PET/CT range verification method. The reproducibility and the consistency of the measured PET signal were found to be of the same order of magnitude. They determine the physical accuracy of the PET measurement to be about 1 mm. However, range discrepancies up to 2.6 mm between two measurements and range variations up to 2.6 mm within one measurement were found at the beam edge and at the edge of the field of view (FOV) of the PET scanner. PET/CT range verification was found to be able to detect small range modifications in the presence of complex tissue inhomogeneities. This study indicates the physical potential of the PET/CT verification method to detect the full-range characteristic of the delivered dose in the patient.

  15. Parents' acceptance and their children's choice of pet for animal-assisted therapy (A.A.T.) in 3- to 12-year-old children in the dental operatory -A questionnaire-based pilot study.

    PubMed

    Gupta, Nidhi; Yadav, Tushar

    2018-04-16

    To evaluate the parents' acceptance to therapy pets, child's most favoured pet, child's choice of soft toy as compared to live pet, and child's preference of his own pet versus therapy pet. Sixty-two children of age groups 3-6 year, 6-9 year, and 9-12 year were selected. The data from completed questionnaires were statistically analysed and subjected to z test, Chi-squared test with P value<0.05 considered as significant. The consent to the presence of pet was given by 41.47% parents of 9- to 12-year-old children, 34.15% parents of 6- to 9-year-old children and 24.39% parents of 3- to 6-year-old children. Children who chose dog as their preferred pet were 56.7%; those who chose cat as their preferred pet were 44%. A majority of 3-to 6-year-olds (63.15%) had dog & cat as their choice, while 6- to 9-year-olds (65.21%) & 9- to 12-year-olds (40%) preferred dogs over all others. Dog was the favourite pet of 46.8% children. More percentage of children wanted pet provided by clinic. Animal-Assisted Therapy (AAT) can prove to be a good behaviour management technique if more parents are made aware and informed about AAT; dog is one of the highly recommended pets for AAT, and therapy pet should be preferred over home pet. © 2018 BSPD, IAPD and John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  16. Imaging Cellular Proliferation During Chemo-Radiotherapy: A Pilot Study of Serial {sup 18}F-FLT Positron Emission Tomography/Computed Tomography Imaging for Non-Small-Cell Lung Cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Everitt, Sarah, E-mail: Sarah.Everitt@petermac.or; Department of Medical Imaging and Radiation Sciences, Faculty of Medicine, Nursing and Health Sciences, Monash University, Clayton, Victoria; Hicks, Rodney J.

    2009-11-15

    Purpose: To establish whether {sup 18}F-3'-deoxy-3'-fluoro-L-thymidine ({sup 18}F-FLT) can monitor changes in cellular proliferation of non-small-cell lung cancer (NSCLC) during radical chemo-radiotherapy (chemo-RT). Methods and Materials: As part of a prospective pilot study, 5 patients with locally advanced NSCLC underwent serial {sup 18}F-FLT positron emission tomography (PET)/computed tomography (CT) scans during treatment. Baseline {sup 18}F-FLT PET/CT scans were compared with routine staging {sup 18}F-FDG PET/CT scans. Two on-treatment {sup 18}F-FLT scans were performed for each patient on Days 2, 8, 15 or 29, providing a range of time points for response assessment. Results: In all 5 patients, baseline lesional uptakemore » of {sup 18}F-FLT on PET/CT corresponded to staging {sup 18}F-FDG PET/CT abnormalities. {sup 18}F-FLT uptake in tumor was observed on five of nine (55%) on-treatment scans, on Days 2, 8 and 29, but not Day 15. A 'flare' of {sup 18}F-FLT uptake in the primary tumor of one case was observed after 2 Gy of radiation (1.22 x baseline). The remaining eight on-treatment scans demonstrated a mean reduction in {sup 18}F-FLT tumor uptake of 0.58 x baseline. A marked reduction of {sup 18}F-FLT uptake in irradiated bone marrow was observed for all cases. This reduction was observed even after only 2 Gy, and all patients demonstrated a complete absence of proliferating marrow after 10 Gy. Conclusions: This proof of concept study indicates that {sup 18}F-FLT uptake can monitor the distinctive biologic responses of epithelial cancers and highly radiosensitive normal tissue changes during radical chemo-RT. Further studies of {sup 18}F-FLT PET/CT imaging during therapy may suggest that this tracer is useful in developing response-adapted RT for NSCLC.« less

  17. Simultaneous whole-body time-of-flight 18F-FDG PET/MRI: a pilot study comparing SUVmax with PET/CT and assessment of MR image quality.

    PubMed

    Iagaru, Andrei; Mittra, Erik; Minamimoto, Ryogo; Jamali, Mehran; Levin, Craig; Quon, Andrew; Gold, Garry; Herfkens, Robert; Vasanawala, Shreyas; Gambhir, Sanjiv Sam; Zaharchuk, Greg

    2015-01-01

    The recent introduction of hybrid PET/MRI scanners in clinical practice has shown promising initial results for several clinical scenarios. However, the first generation of combined PET/MRI lacks time-of-flight (TOF) technology. Here we report the results of the first patients to be scanned on a completely novel fully integrated PET/MRI scanner with TOF. We analyzed data from patients who underwent a clinically indicated F FDG PET/CT, followed by PET/MRI. Maximum standardized uptake values (SUVmax) were measured from F FDG PET/MRI and F FDG PET/CT for lesions, cerebellum, salivary glands, lungs, aortic arch, liver, spleen, skeletal muscle, and fat. Two experienced radiologists independently reviewed the MR data for image quality. Thirty-six patients (19 men, 17 women, mean [±standard deviation] age of 61 ± 14 years [range: 27-86 years]) with a total of 69 discrete lesions met the inclusion criteria. PET/CT images were acquired at a mean (±standard deviation) of 74 ± 14 minutes (range: 49-100 minutes) after injection of 10 ± 1 mCi (range: 8-12 mCi) of F FDG. PET/MRI scans started at 161 ± 29 minutes (range: 117 - 286 minutes) after the F FDG injection. All lesions identified on PET from PET/CT were also seen on PET from PET/MRI. The mean SUVmax values were higher from PET/MRI than PET/CT for all lesions. No degradation of MR image quality was observed. The data obtained so far using this investigational PET/MR system have shown that the TOF PET system is capable of excellent performance during simultaneous PET/MR with routine pulse sequences. MR imaging was not compromised. Comparison of the PET images from PET/CT and PET/MRI show no loss of image quality for the latter. These results support further investigation of this novel fully integrated TOF PET/MRI instrument.

  18. Evaluation of 18-F-fluoro-2-deoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT) as a staging and monitoring tool for dogs with stage-2 splenic hemangiosarcoma - A pilot study.

    PubMed

    Borgatti, Antonella; Winter, Amber L; Stuebner, Kathleen; Scott, Ruth; Ober, Christopher P; Anderson, Kari L; Feeney, Daniel A; Vallera, Daniel A; Koopmeiners, Joseph S; Modiano, Jaime F; Froelich, Jerry

    2017-01-01

    Positron Emission Tomography-Computed Tomography (PET-CT) is routinely used for staging and monitoring of human cancer patients and is becoming increasingly available in veterinary medicine. In this study, 18-fluorodeoxyglucose (18FDG)-PET-CT was used in dogs with naturally occurring splenic hemangiosarcoma (HSA) to assess its utility as a staging and monitoring modality as compared to standard radiography and ultrasonography. Nine dogs with stage-2 HSA underwent 18FDG-PET-CT following splenectomy and prior to commencement of chemotherapy. Routine staging (thoracic radiography and abdominal ultrasonography) was performed prior to 18FDG-PET-CT in all dogs. When abnormalities not identified on routine tests were noted on 18FDG-PET-CT, owners were given the option to repeat a PET-CT following treatment with eBAT. A PET-CT scan was repeated on Day 21 in three dogs. Abnormalities not observed on conventional staging tools, and most consistent with malignant disease based on location, appearance, and outcome, were detected in two dogs and included a right atrial mass and a hepatic nodule, respectively. These lesions were larger and had higher metabolic activity on the second scans. 18FDG-PET-CT has potential to provide important prognostic information and influence treatment recommendations for dogs with stage-2 HSA. Additional studies will be needed to precisely define the value of this imaging tool for staging and therapy monitoring in dogs with this and other cancers.

  19. Evaluation of 18-F-fluoro-2-deoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT) as a staging and monitoring tool for dogs with stage-2 splenic hemangiosarcoma – A pilot study

    PubMed Central

    Winter, Amber L.; Stuebner, Kathleen; Scott, Ruth; Ober, Christopher P.; Anderson, Kari L.; Feeney, Daniel A.; Vallera, Daniel A.; Koopmeiners, Joseph S.; Modiano, Jaime F.; Froelich, Jerry

    2017-01-01

    Positron Emission Tomography-Computed Tomography (PET-CT) is routinely used for staging and monitoring of human cancer patients and is becoming increasingly available in veterinary medicine. In this study, 18-fluorodeoxyglucose (18FDG)-PET-CT was used in dogs with naturally occurring splenic hemangiosarcoma (HSA) to assess its utility as a staging and monitoring modality as compared to standard radiography and ultrasonography. Nine dogs with stage-2 HSA underwent 18FDG-PET-CT following splenectomy and prior to commencement of chemotherapy. Routine staging (thoracic radiography and abdominal ultrasonography) was performed prior to 18FDG-PET-CT in all dogs. When abnormalities not identified on routine tests were noted on 18FDG-PET-CT, owners were given the option to repeat a PET-CT following treatment with eBAT. A PET-CT scan was repeated on Day 21 in three dogs. Abnormalities not observed on conventional staging tools, and most consistent with malignant disease based on location, appearance, and outcome, were detected in two dogs and included a right atrial mass and a hepatic nodule, respectively. These lesions were larger and had higher metabolic activity on the second scans. 18FDG-PET-CT has potential to provide important prognostic information and influence treatment recommendations for dogs with stage-2 HSA. Additional studies will be needed to precisely define the value of this imaging tool for staging and therapy monitoring in dogs with this and other cancers. PMID:28222142

  20. Using Concept Mapping and Paraphrasing for Reading Comprehension

    ERIC Educational Resources Information Center

    Marashi, Hamid; Bagheri, Nazanin

    2015-01-01

    This study investigated the comparative impact of two types of teaching techniques, namely concept mapping and paraphrasing, on the reading comprehension of EFL learners. For this purpose, 60 learners of a total number of 90 intermediate learners studying at a language school in Karaj, Iran, were chosen through taking a piloted PET for…

  1. Productive Partnerships: Pilot Program Brings Teachers and SPCA Together.

    ERIC Educational Resources Information Center

    Kukulka, Judi; Soltow, Willow

    1984-01-01

    A pilot program providing a comprehensive humane education curriculum is described. Packets containing instructional material on animal classification, pet care, wildlife, animal communication, and human activism are provided to teachers. In addition, school visits make it possible to demonstrate the activities, and motivate teachers to make…

  2. Repurposing the Microsoft Kinect for Windows v2 for external head motion tracking for brain PET.

    PubMed

    Noonan, P J; Howard, J; Hallett, W A; Gunn, R N

    2015-11-21

    Medical imaging systems such as those used in positron emission tomography (PET) are capable of spatial resolutions that enable the imaging of small, functionally important brain structures. However, the quality of data from PET brain studies is often limited by subject motion during acquisition. This is particularly challenging for patients with neurological disorders or with dynamic research studies that can last 90 min or more. Restraining head movement during the scan does not eliminate motion entirely and can be unpleasant for the subject. Head motion can be detected and measured using a variety of techniques that either use the PET data itself or an external tracking system. Advances in computer vision arising from the video gaming industry could offer significant benefits when re-purposed for medical applications. A method for measuring rigid body type head motion using the Microsoft Kinect v2 is described with results presenting  ⩽0.5 mm spatial accuracy. Motion data is measured in real-time at 30 Hz using the KinectFusion algorithm. Non-rigid motion is detected using the residual alignment energy data of the KinectFusion algorithm allowing for unreliable motion to be discarded. Motion data is aligned to PET listmode data using injected pulse sequences into the PET/CT gantry allowing for correction of rigid body motion. Pilot data from a clinical dynamic PET/CT examination is shown.

  3. Repurposing the Microsoft Kinect for Windows v2 for external head motion tracking for brain PET

    NASA Astrophysics Data System (ADS)

    Noonan, P. J.; Howard, J.; Hallett, W. A.; Gunn, R. N.

    2015-11-01

    Medical imaging systems such as those used in positron emission tomography (PET) are capable of spatial resolutions that enable the imaging of small, functionally important brain structures. However, the quality of data from PET brain studies is often limited by subject motion during acquisition. This is particularly challenging for patients with neurological disorders or with dynamic research studies that can last 90 min or more. Restraining head movement during the scan does not eliminate motion entirely and can be unpleasant for the subject. Head motion can be detected and measured using a variety of techniques that either use the PET data itself or an external tracking system. Advances in computer vision arising from the video gaming industry could offer significant benefits when re-purposed for medical applications. A method for measuring rigid body type head motion using the Microsoft Kinect v2 is described with results presenting  ⩽0.5 mm spatial accuracy. Motion data is measured in real-time at 30 Hz using the KinectFusion algorithm. Non-rigid motion is detected using the residual alignment energy data of the KinectFusion algorithm allowing for unreliable motion to be discarded. Motion data is aligned to PET listmode data using injected pulse sequences into the PET/CT gantry allowing for correction of rigid body motion. Pilot data from a clinical dynamic PET/CT examination is shown.

  4. [(18)F]-fluorodeoxyglucose positron emission tomography of the cat brain: A feasibility study to investigate osteoarthritis-associated pain.

    PubMed

    Guillot, Martin; Chartrand, Gabriel; Chav, Ramnada; Rousseau, Jacques; Beaudoin, Jean-François; Martel-Pelletier, Johanne; Pelletier, Jean-Pierre; Lecomte, Roger; de Guise, Jacques A; Troncy, Eric

    2015-06-01

    The objective of this pilot study was to investigate central nervous system (CNS) changes related to osteoarthritis (OA)-associated chronic pain in cats using [(18)F]-fluorodeoxyglucose ((18)FDG) positron emission tomography (PET) imaging. The brains of five normal, healthy (non-OA) cats and seven cats with pain associated with naturally occurring OA were imaged using (18)FDG-PET during a standardized mild anesthesia protocol. The PET images were co-registered over a magnetic resonance image of a cat brain segmented into several regions of interest. Brain metabolism was assessed in these regions using standardized uptake values. The brain metabolism in the secondary somatosensory cortex, thalamus and periaqueductal gray matter was increased significantly (P ≤ 0.005) in OA cats compared with non-OA cats. This study indicates that (18)FDG-PET brain imaging in cats is feasible to investigate CNS changes related to chronic pain. The results also suggest that OA is associated with sustained nociceptive inputs and increased activity of the descending modulatory pathways. Copyright © 2015 Elsevier Ltd. All rights reserved.

  5. Pet owners' attitudes and behaviours related to smoking and second-hand smoke: a pilot study.

    PubMed

    Milberger, S M; Davis, R M; Holm, A L

    2009-04-01

    Although research indicates that second-hand smoke (SHS) harms both human and animal health, data on the percentage of pet owners who smoke or allow smoking in their homes are not readily available. To investigate pet owners' smoking behaviour and policies on smoking in their homes, and the potential for educational interventions to motivate change in pet owners' smoking behaviour. A web-based survey was used with 3293 adult pet owners. The main outcome measures were smoking behaviour of pet owners and their cohabitants; policies on smoking in pet owners' homes; and impact of information about the dangers of pet exposure to SHS on pet owners' smoking intentions. Of respondents, 21% were current smokers and 27% of participants lived with at least one smoker. Pet owners who smoke reported that information on the dangers of pet exposure to SHS would motivate them to try to quit smoking (28.4%) and ask the people with whom they live to quit smoking (8.7%) or not to smoke indoors (14.2%). Moreover, non-smoking pet owners who live with smokers said that they would ask the people with whom they live to quit (16.4%) or not smoke indoors (24.2%) if given this information. About 40% of current smokers and 24% of non-smokers living with smokers indicated that they would be interested in receiving information on smoking, quitting, or SHS. Educational campaigns informing pet owners of the risks of SHS exposure for pets could motivate some owners to quit smoking. It could also motivate these owners and non-smoking owners who cohabit with smokers make their homes smoke-free.

  6. F-18-FDG-PET Confined Radiotherapy of Locally Advanced NSCLC With Concomitant Chemotherapy: Results of the PET-PLAN Pilot Trial

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fleckenstein, Jochen; Hellwig, Dirk; Kremp, Stephanie

    2011-11-15

    Purpose: The integration of fluoro-deoxy-D-glucose positron emission tomography (FDG-PET) in the process of radiotherapy (RT) planning of locally advanced non-small-cell lung cancer (NSCLC) may improve diagnostic accuracy and minimize interobserver variability compared with target volume definition solely based on computed tomography. Furthermore, irradiating only FDG-PET-positive findings and omitting elective nodal regions may allow dose escalation by treating smaller volumes. The aim of this prospective pilot trial was to evaluate the therapeutic safety of FDG-PET-based RT treatment planning with an autocontour-derived delineation of the primary tumor. Methods and Materials: Eligible patients had Stages II-III inoperable NSCLC, and simultaneous, platinum-based radiochemotherapy wasmore » indicated. FDG-PET and computed tomography acquisitions in RT treatment planning position were coregistered. The clinical target volume (CTV) included the FDG-PET-defined primary tumor, which was autodelineated with a source-to-background algorithm, plus FDG-PET-positive lymph node stations. Limited by dose restrictions for normal tissues, prescribed total doses were in the range of 66.6 to 73.8 Gy. The primary endpoint was the rate of out-of-field isolated nodal recurrences (INR). Results: As per intent to treat, 32 patients received radiochemotherapy. In 15 of these patients, dose escalation above 66.6 Gy was achieved. No Grade 4 toxicities occurred. After a median follow-up time of 27.2 months, the estimated median survival time was 19.3 months. During the observation period, one INR was observed in 23 evaluable patients. Conclusions: FDG-PET-confined target volume definition in radiochemotherapy of NSCLC, based on a contrast-oriented source-to-background algorithm, was associated with a low risk of INR. It might provide improved tumor control because of dose escalation.« less

  7. A novel behavioral intervention in adolescents with type 1 diabetes mellitus improves glycemic control: preliminary results from a pilot randomized control trial.

    PubMed

    Maranda, Louise; Lau, May; Stewart, Sunita M; Gupta, Olga T

    2015-04-01

    The purpose of this study was to develop and pilot-test an innovative behavioral intervention in adolescents with type 1 diabetes mellitus (T1DM) incorporating structured care of a pet to improve glycemic control. Twenty-eight adolescents with A1C > 8.5% (69 mmol/mol) were randomly assigned to either the intervention group (care of a Betta splendens pet fish) or the control group (usual care). Adolescents in the intervention group were given instructions to associate daily and weekly fish care duties with diabetes self-management tasks, including blood glucose testing and parent-adolescent communication. After 3 months, the participants in the intervention group exhibited a statistically significant decrease in A1C level (-0.5%) compared with their peers in the control group, who had an increase in A1C level (0.8%) (P = .04). The younger adolescents (10-13 years of age) demonstrated a greater response to the intervention, which was statistically significant (-1.5% vs 0.6%, P = .04), compared with the older adolescents (14-17 years of age). Structured care of a pet fish can improve glycemic control in adolescents with T1DM, likely by providing cues to perform diabetes self-management behaviors. © 2015 The Author(s).

  8. Reduced ventilation-perfusion (V/Q) mismatch following endobronchial valve insertion demonstrated by Gallium-68 V/Q photon emission tomography/computed tomography.

    PubMed

    Leong, Paul; Le Roux, Pierre-Yves; Callahan, Jason; Siva, Shankar; Hofman, Michael S; Steinfort, Daniel P

    2017-09-01

    Endobronchial valves (EBVs) are increasingly deployed in the management of severe emphysema. Initial studies focussed on volume reduction as the mechanism, with subsequent improvement in forced expiratory volume in 1 s (FEV 1 ). More recent studies have emphasized importance of perfusion on predicting outcomes, though findings have been inconsistent. Gallium-68 ventilation-perfusion (V/Q) photon emission tomography (PET)/computed tomography (CT) is a novel imaging modality with advantages in spatial resolution, quantitation, and speed over conventional V/Q scintigraphy. We report a pilot case in which V/Q-PET/CT demonstrated discordant findings compared with quantitative CT analysis, and directed left lower lobe EBV placement. The patient experienced a significant improvement in 6-min walk distance (6MWD) without change in spirometry. Post-EBV V/Q-PET/CT demonstrated a marked decrease in unmatched (detrimental) V/Q areas and improvement in overall V/Q matching on post-EBV V/Q-PET/CT. These preliminary novel findings suggest that EBVs improve V/Q matching and may explain the observed functional improvements.

  9. Microcomputers in the Classroom: Trojan Horse or Teacher's Pet?

    ERIC Educational Resources Information Center

    Olson, John K.

    Arguing that curriculum developers need to seek a better understanding of existing classroom orders before advising reform through new technology, this paper presents a review of research on the effects of microcomputers on the stabilities of classroom practice and describes a pilot study currently underway at Queens University in Ontario to…

  10. Evaluation of a pet-assisted living intervention for improving functional status in assisted living residents with mild to moderate cognitive impairment: a pilot study.

    PubMed

    Friedmann, Erika; Galik, Elizabeth; Thomas, Sue A; Hall, P Sue; Chung, Seon Yoon; McCune, Sandra

    2015-05-01

    In older adults with cognitive impairment (CI), decreased functional status and increased behavioral symptoms require relocation from assisted living (AL) to nursing homes. Studies support positive effects of pets on health/function. Evaluate the effectiveness of the Pet AL (PAL) intervention to support physical, behavioral, and emotional function in AL residents with CI. Cognitively impaired AL residents randomized to 60-90 minute sessions [PAL (n = 22) or reminiscing (n = 18)] twice/week for 12 weeks. PAL interventionist encourages residents to perform skills with the visiting dog; reminiscing interventionist encourages residents to reminisce. Monthly assessment of physical (energy expenditure, activities of daily living), emotional (depression, apathy), and behavioral (agitation) function. In linear mixed models, physical activity depressive symptoms improved more with PAL. Evidence supports that the PAL program helps preserve/enhance function of AL residents with CI. Additional study is required to evaluate the duration and predictors of effectiveness of the PAL intervention. © The Author(s) 2014.

  11. A dual tracer (68)Ga-DOTANOC PET/CT and (18)F-FDG PET/CT pilot study for detection of cardiac sarcoidosis.

    PubMed

    Gormsen, Lars C; Haraldsen, Ate; Kramer, Stine; Dias, Andre H; Kim, Won Yong; Borghammer, Per

    2016-12-01

    Cardiac sarcoidosis (CS) is a potentially fatal condition lacking a single test with acceptable diagnostic accuracy. (18)F-FDG PET/CT has emerged as a promising imaging modality, but is challenged by physiological myocardial glucose uptake. An alternative tracer, (68)Ga-DOTANOC, binds to somatostatin receptors on inflammatory cells in sarcoid granulomas. We therefore aimed to conduct a proof-of-concept study using (68)Ga-DOTANOC to diagnose CS. In addition, we compared diagnostic accuracy and inter-observer variability of (68)Ga-DOTANOC vs. (18)F-FDG PET/CT. Nineteen patients (seven female) with suspected CS were prospectively recruited and dual tracer scanned within 7 days. PET images were reviewed by four expert readers for signs of CS and compared to the reference standard (Japanese ministry of Health and Welfare CS criteria). CS was diagnosed in 3/19 patients. By consensus, 11/19 (18)F-FDG scans and 0/19 (68)Ga-DOTANOC scans were rated as inconclusive. The sensitivity of (18)F-FDG PET for diagnosing CS was 33 %, specificity was 88 %, PPV was 33 %, NPV was 88 %, and diagnostic accuracy was 79 %. For (68)Ga-DOTANOC, accuracy was 100 %. Inter-observer agreement was poor for (18)F-FDG PET (Fleiss' combined kappa 0.27, NS) and significantly better for (68)Ga-DOTANOC (Fleiss' combined kappa 0.46, p = 0.001). Despite prolonged pre-scan fasting, a large proportion of (18)F-FDG PET/CT images were rated as inconclusive, resulting in low agreement among reviewers and correspondingly poor diagnostic accuracy. By contrast, (68)Ga-DOTANOC PET/CT had excellent diagnostic accuracy with the caveat that inter-observer variability was still significant. Nevertheless, (68)Ga-DOTANOC PET/CT looks very promising as an alternative CS PET tracer. Current Controlled Trials NCT01729169 .

  12. Endobronchial ultrasound-guided lymph node biopsy with transbronchial needle forceps: a pilot study.

    PubMed

    Herth, F J F; Schuler, H; Gompelmann, D; Kahn, N; Gasparini, S; Ernst, A; Schuhmann, M; Eberhardt, R

    2012-02-01

    One limitation of endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is the size of the available needles, frequently yielding only cells for cytological examination. The aim of this pilot study was to evaluate the efficacy and safety of newly developed needle forceps to obtain tissue for the histological diagnosis of enlarged mediastinal lymph nodes. Patients with enlarged, positron emission tomography (PET)-positive lymph nodes were included. The transbronchial needle forceps (TBNF), a sampling instrument combining the characteristics of a needle (bevelled tip for penetrating through the bronchial wall) with forceps (two serrated jaws for grasping tissue) was used through the working channel of the EBUS-TBNA scope. Efficacy and safety was assessed. 50 patients (36 males and 14 females; mean age 51 yrs) with enlarged or PET-positive lymph nodes were included in this pilot study. In 48 (96%) patients penetration of the bronchial wall was possible and in 45 patients tissue for histological diagnosis was obtained. In three patients TBNF provided inadequate material. For patients in whom the material was adequate for a histological examination, a specific diagnosis was established in 43 (86%) out of 50 patients (nonsmall cell lung cancer: n=24; small cell lung cancer: n=7; sarcoidosis: n=4; Hodgkin's lymphoma: n=4; tuberculosis: n=2; and non-Hodgkin's lymphoma: n=2).No clinically significant procedure-related complications were encountered. This study demonstrated that EBUS-TBNF is a safe procedure and provides diagnostic histological specimens of mediastinal lymph nodes.

  13. Localization of Hidden Insulinomas with ⁶⁸Ga-DOTA-Exendin-4 PET/CT: A Pilot Study.

    PubMed

    Antwi, Kwadwo; Fani, Melpomeni; Nicolas, Guillaume; Rottenburger, Christof; Heye, Tobias; Reubi, Jean Claude; Gloor, Beat; Christ, Emanuel; Wild, Damian

    2015-07-01

    (111)In-DOTA-exendin-4 SPECT/CT has been shown to be highly efficient in the detection of insulinomas. We aimed at determining whether novel PET/CT imaging with [Nle(14),Lys(40)(Ahx-DOTA-(68)Ga)NH2]exendin-4 ((68)Ga-DOTA-exendin-4) is feasible and sensitive in detecting benign insulinomas. (68)Ga-DOTA-exendin-4 PET/CT and (111)In-DOTA-exendin-4 SPECT/CT were performed in a randomized cross-over order on 5 patients with endogenous hyperinsulinemic hypoglycemia. The gold standard for comparison was the histologic diagnosis after surgery. In 4 patients histologic diagnosis confirmed a benign insulinoma, whereas one patient refused surgery despite a positive (68)Ga-DOTA-exendin-4 PET/CT scan. In 4 of 5 patients, previously performed conventional imaging (CT or MR imaging) was not able to localize the insulinoma. (68)Ga-DOTA-exendin-4 PET/CT correctly identified the insulinoma in 4 of 4 patients, whereas (111)In-DOTA-exendin-4 SPECT/CT correctly identified the insulinoma in only 2 of 4 patients. These preliminary data suggest that the use of (68)Ga-DOTA-exendin-4 PET/CT in detecting hidden insulinomas is feasible. © 2015 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  14. GM1 ganglioside in Parkinson's disease: Pilot study of effects on dopamine transporter binding.

    PubMed

    Schneider, Jay S; Cambi, Franca; Gollomp, Stephen M; Kuwabara, Hiroto; Brašić, James R; Leiby, Benjamin; Sendek, Stephanie; Wong, Dean F

    2015-09-15

    GM1 ganglioside has been suggested as a treatment for Parkinson's disease (PD), potentially having symptomatic and disease modifying effects. The current pilot imaging study was performed to examine effects of GM1 on dopamine transporter binding, as a surrogate measure of disease progression, studied longitudinally. Positron emission tomography (PET) imaging data were obtained from a subset of subjects enrolled in a delayed start clinical trial of GM1 in PD [1]: 15 Early-start (ES) subjects, 14 Delayed-start (DS) subjects, and 11 Comparison (standard-of-care) subjects. Treatment subjects were studied over a 2.5 year period while Comparison subjects were studied over 2 years. Dynamic PET scans were performed over 90 min following injection of [(11)C]methylphenidate. Regional values of binding potential (BPND) were analyzed for several striatal volumes of interest. Clinical results for this subset of subjects were similar to those previously reported for the larger study group. ES subjects showed early symptomatic improvement and slow symptom progression over the study period. DS and Comparison subjects were initially on the same symptom progression trajectory but diverged once DS subjects received GM1 treatment. Imaging results showed significant slowing of BPND loss in several striatal regions in GM1-treated subjects and in some cases, an increased BPND in some striatal regions was detected after GM1 use. Results of this pilot imaging study provide additional data to suggest a potential disease modifying effect of GM1 on PD. These results need to be confirmed in a larger number of subjects. Copyright © 2015 Elsevier B.V. All rights reserved.

  15. High-resolution imaging of the large non-human primate brain using microPET: a feasibility study

    NASA Astrophysics Data System (ADS)

    Naidoo-Variawa, S.; Hey-Cunningham, A. J.; Lehnert, W.; Kench, P. L.; Kassiou, M.; Banati, R.; Meikle, S. R.

    2007-11-01

    The neuroanatomy and physiology of the baboon brain closely resembles that of the human brain and is well suited for evaluating promising new radioligands in non-human primates by PET and SPECT prior to their use in humans. These studies are commonly performed on clinical scanners with 5 mm spatial resolution at best, resulting in sub-optimal images for quantitative analysis. This study assessed the feasibility of using a microPET animal scanner to image the brains of large non-human primates, i.e. papio hamadryas (baboon) at high resolution. Factors affecting image accuracy, including scatter, attenuation and spatial resolution, were measured under conditions approximating a baboon brain and using different reconstruction strategies. Scatter fraction measured 32% at the centre of a 10 cm diameter phantom. Scatter correction increased image contrast by up to 21% but reduced the signal-to-noise ratio. Volume resolution was superior and more uniform using maximum a posteriori (MAP) reconstructed images (3.2-3.6 mm3 FWHM from centre to 4 cm offset) compared to both 3D ordered subsets expectation maximization (OSEM) (5.6-8.3 mm3) and 3D reprojection (3DRP) (5.9-9.1 mm3). A pilot 18F-2-fluoro-2-deoxy-d-glucose ([18F]FDG) scan was performed on a healthy female adult baboon. The pilot study demonstrated the ability to adequately resolve cortical and sub-cortical grey matter structures in the baboon brain and improved contrast when images were corrected for attenuation and scatter and reconstructed by MAP. We conclude that high resolution imaging of the baboon brain with microPET is feasible with appropriate choices of reconstruction strategy and corrections for degrading physical effects. Further work to develop suitable correction algorithms for high-resolution large primate imaging is warranted.

  16. A Pilot Comparison of 18F-fluorocholine PET/CT, Ultrasonography and 123I/99mTc-sestaMIBI Dual-Phase Dual-Isotope Scintigraphy in the Preoperative Localization of Hyperfunctioning Parathyroid Glands in Primary or Secondary Hyperparathyroidism

    PubMed Central

    Michaud, Laure; Balogova, Sona; Burgess, Alice; Ohnona, Jessica; Huchet, Virginie; Kerrou, Khaldoun; Lefèvre, Marine; Tassart, Marc; Montravers, Françoise; Périé, Sophie; Talbot, Jean-Noël

    2015-01-01

    Abstract We compared 18F-fluorocholine hybrid positron emission tomography/X-ray computed tomography (FCH-PET/CT) with ultrasonography (US) and scintigraphy in patients with hyperparathyroidism and discordant, or equivocal results of US and 123I/99mTc-sesta-methoxyisobutylisonitrile (sestaMIBI) dual-phase parathyroid scintigraphy. FCH-PET/CT was performed in 17 patients with primary (n = 11) lithium induced (n = 1) or secondary hyperparathyroidism (1 dialyzed, 4 renal-transplanted). The reference standard was based on results of surgical exploration and histopathological examination. The results of imaging modalities were evaluated, on site and by masked reading, on per-patient and per-lesion bases. In a first approach, equivocal images/foci were considered as negative. On a per-patient level, the sensitivity was for US 38%, for scintigraphy 69% by open and 94% by masked reading, and for FCH-PET/CT 88% by open and 94% by masked reading. On a per-lesion level, sensitivity was for US 42%, for scintigraphy 58% by open and 83% by masked reading, and for FCH-PET/CT 88% by open and 96% by masked reading. One ectopic adenoma was missed by the 3 imaging modalities. Considering equivocal images/foci as positive increased the accuracy of the open reading of scintigraphy or of FCH-PET/CT, but not of US. FCH-PET/CT was significantly superior to US in all approaches, whereas it was more sensitive than scintigraphy only for open reading considering equivocal images/foci as negative (P = 0.04). FCH uptake was more intense in adenomas than in hyperplastic parathyroid glands. Thyroid lesions were suspected in 9 patients. They may induce false-positive results as in one case of oncocytic thyroid adenoma, or false-negative results as in one case of intrathyroidal parathyroid adenoma. Thyroid cancer (4 cases) can be visualized with FCH as with 99mTc-sestaMIBI, but the intensity of uptake was moderate, similar to that of parathyroid hyperplasia. This pilot study confirmed that FCH-PET/CT is an adequate imaging tool in patients with primary or secondary hyperparathyroidism, since both adenomas and hyperplastic parathyroid glands can be detected. The sensitivity of FCH-PET/CT was better than that of US and was not inferior to that of dual-phase dual-isotope 123I/99mTc-scintigraphy. Further studies should evaluate whether FCH could replace 99mTc-sestaMIBI as the functional agent for parathyroid imaging, but US would still be useful to identify thyroid lesions. PMID:26469908

  17. 18F-FLT PET/CT in the Evaluation of Pheochromocytomas and Paragangliomas: A Pilot Study.

    PubMed

    Blanchet, Elise M; Taieb, David; Millo, Corina; Martucci, Victoria; Chen, Clara C; Merino, Maria; Herscovitch, Peter; Pacak, Karel

    2015-12-01

    (18)F-FDG PET/CT has been proven to be a highly sensitive method for pheochromocytomas/paragangliomas (PHEOs/PGLs) associated with succinate dehydrogenase (SDH) mutations. This finding has been attributed to altered tumor cell metabolism resulting from these mutations and does not provide additional prognostic information to genotype. Therefore, identification of new biomarkers for aggressiveness is needed. A high Ki-67 index was proposed to be an additional prognostic factor. This pilot study aimed to evaluate 3'-deoxy-3'-(18)F-fluorothymidine ((18)F-FLT) PET/CT, a PET proliferation tracer, as a potential imaging agent in a series of 12 PHEO/PGL patients with different genetic backgrounds, to compare (18)F-FLT uptake with (18)F-FDG PET/CT, and to evaluate classic factors of aggressiveness. Twelve patients (7 metastatic and 5 nonmetastatic) were prospectively evaluated with (18)F-FDG and (18)F-FLT and followed for at least 2 y after the initial imaging work-up. Uptake was assessed at a lesion level, visually and quantitatively by maximum standardized uptake values (SUVmax) for both tracers. (18)F-FLT uptake was compared with risk factors known to be linked with a poor prognosis in PGLs (SDHB-mutated status, lesion size, dopaminergic phenotype) and with (18)F-FDG uptake. In 12 patients, 77 lesions were assessed. All lesions had low (18)F-FLT uptake (median SUVmax, 2.25; range, 0.7-4.5). There was no apparent superiority of (18)F-FLT uptake in progressive lesions, and most of the lesions showed a mismatch, with high (18)F-FDG uptake (median SUVmax, 10.8; range, 1.1-79.0) contrasting with low (18)F-FLT uptake. This study suggests that PHEOs/PGLs-even those that progress-do not exhibit intense (18)F-FLT uptake. It provides the first in vivo demonstration that proliferation may not be a major determinant of (18)F-FDG uptake in these tumors. These findings provide new insight into the biologic behavior of PGL and suggest that antiproliferative agents may be suboptimal for treatment of these tumors. © 2015 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  18. Early dynamic 18F-FDG PET to detect hyperperfusion in hepatocellular carcinoma liver lesions.

    PubMed

    Schierz, Jan-Henning; Opfermann, Thomas; Steenbeck, Jörg; Lopatta, Eric; Settmacher, Utz; Stallmach, Andreas; Marlowe, Robert J; Freesmeyer, Martin

    2013-06-01

    In addition to angiographic data on vascularity and vascular access, demonstration of hepatocellular carcinoma (HCC) liver nodule hypervascularization is a prerequisite for certain intrahepatic antitumor therapies. Early dynamic (ED) (18)F-FDG PET/CT could serve this purpose when the current standard method, contrast-enhanced (CE) CT, or other CE morphologic imaging modalities are unsuitable. A recent study showed ED (18)F-FDG PET/CT efficacy in this setting but applied a larger-than-standard (18)F-FDG activity and an elaborate protocol likely to hinder routine use. We developed a simplified protocol using standard activities and easily generated visual and descriptive or quantitative endpoints. This pilot study assessed the ability of these endpoints to detect HCC hyperperfusion and, thereby, evaluated the suitability in of the protocol everyday practice. Twenty-seven patients with 34 HCCs (diameter ≥ 1.5 cm) with hypervascularization on 3-phase CE CT underwent liver ED (18)F-FDG PET for 240 s, starting with (18)F-FDG (250-MBq bolus injection). Four frames at 15-s intervals, followed by 3 frames at 60-s intervals were reconstructed. Endpoints included focal tracer accumulation in the first 4 frames (60 s), subsequent focal washout, and visual and quantitative differences between tumor and liver regions of interest in maximum and mean ED standardized uptake value (ED SUVmax and ED SUVmean, respectively) 240-s time-activity curves. All 34 lesions were identified by early focal (18)F-FDG accumulation and faster time-to-peak ED SUVmax or ED SUVmean than in nontumor tissue. Tumor peak ED SUVmax and ED SUVmean exceeded liver levels in 85% and 53%, respectively, of lesions. Nadir tumor signal showed no consistent pattern relative to nontumor signal. HCC had a significantly shorter time to peak and significantly faster rate to peak for both ED SUVmax and ED SUVmean curves and a significantly higher peak ED SUVmax but not peak ED SUVmean than the liver. This pilot study provided proof of principle that our simplified ED (18)F-FDG PET/CT protocol includes endpoints that effectively detect HCC hypervascularization; this finding suggests that the protocol can be used routinely.

  19. CT-based texture analysis potentially provides prognostic information complementary to interim fdg-pet for patients with hodgkin's and aggressive non-hodgkin's lymphomas.

    PubMed

    Ganeshan, B; Miles, K A; Babikir, S; Shortman, R; Afaq, A; Ardeshna, K M; Groves, A M; Kayani, I

    2017-03-01

    The purpose of this study was to investigate the ability of computed tomography texture analysis (CTTA) to provide additional prognostic information in patients with Hodgkin's lymphoma (HL) and high-grade non-Hodgkin's lymphoma (NHL). This retrospective, pilot-study approved by the IRB comprised 45 lymphoma patients undergoing routine 18F-FDG-PET-CT. Progression-free survival (PFS) was determined from clinical follow-up (mean-duration: 40 months; range: 10-62 months). Non-contrast-enhanced low-dose CT images were submitted to CTTA comprising image filtration to highlight features of different sizes followed by histogram-analysis using kurtosis. Prognostic value of CTTA was compared to PET FDG-uptake value, tumour-stage, tumour-bulk, lymphoma-type, treatment-regime, and interim FDG-PET (iPET) status using Kaplan-Meier analysis. Cox regression analysis determined the independence of significantly prognostic imaging and clinical features. A total of 27 patients had aggressive NHL and 18 had HL. Mean PFS was 48.5 months. There was no significant difference in pre-treatment CTTA between the lymphoma sub-types. Kaplan-Meier analysis found pre-treatment CTTA (medium feature scale, p=0.010) and iPET status (p<0.001) to be significant predictors of PFS. Cox analysis revealed that an interaction between pre-treatment CTTA and iPET status was the only independent predictor of PFS (HR: 25.5, 95% CI: 5.4-120, p<0.001). Specifically, pre-treatment CTTA risk stratified patients with negative iPET. CTTA can potentially provide prognostic information complementary to iPET for patients with HL and aggressive NHL. • CT texture-analysis (CTTA) provides prognostic information complementary to interim FDG-PET in Lymphoma. • Pre-treatment CTTA and interim PET status were significant predictors of progression-free survival. • Patients with negative interim PET could be further stratified by pre-treatment CTTA. • Provide precision surveillance where additional imaging reserved for patients at greatest recurrence-risk. • Assists in risk-adapted treatment strategy based on interim PET and CTTA.

  20. Low-activity 124I-PET/low-dose CT versus 99mTc-pertechnetate planar scintigraphy or 99mTc-pertechnetate single-photon emission computed tomography of the thyroid: a pilot comparison.

    PubMed

    Darr, Andreas M; Opfermann, Thomas; Niksch, Tobias; Driesch, Dominik; Marlowe, Robert J; Freesmeyer, Martin

    2013-10-01

    The standard thyroid functional imaging method, 99mTc-pertechnetate (99mTc-PT) planar scintigraphy, has technical drawbacks decreasing its sensitivity in detecting nodules or anatomical pathology. 124I-PET, lacking these disadvantages and allowing simultaneous CT, may have greater sensitivity for these purposes. We performed a blinded pilot comparison of 124I-PET(/CT) versus 99mTc-PT planar scintigraphy or its cross-sectional enhancement, 99mTc-PT single-photon emission CT (SPECT), in characterizing the thyroid gland with benign disease. Twenty-one consecutive adults with goiter underwent low-activity (1 MBq/0.027 mCi) 124I-PET/low-dose (30 mAs) CT, 99mTc-PT planar scintigraphy, and 99mTc-PT-SPECT. Endpoints included the numbers of “hot spots” with/without central photopenia and “cold spots” detected, the proportion of these lesions with morphological correlates, the mean volume and diameter of visualized nodules, and the number of cases of lobus pyramidalis or retrosternal thyroid tissue identified. 124I-PET detected significantly more “hot spots” with/without central photopenia (P < 0.001), significantly more nodules (P < 0.001), and more “cold spots” than did 99mTc-PT planar scintigraphy or 99mTc-PT-SPECT, including all lesions seen on the 99mTc-PT modalities. Ultrasonographic correlates were found for all nodules visualized on all 3 modalities and 92.5% of nodules seen only on 124I-PET. Nodules discernible only on 124I-PET had significantly smaller mean volume or diameter (P < 0.001) than did those visualized on 99mTc-PT planar scintigraphy or 99mTc-PT-SPECT. 124I-PET(/CT) identified significantly more patients with a lobus pyramidalis (P < 0.001) or retrosternal thyroid tissue (P < 0.05). 124I-PET(/CT) may provide superior imaging of benign thyroid disease compared to planar or cross-sectional 99mTc-PT scintigraphy.

  1. Using Convergent and Divergent Tasks to Improve Writing and Language Learning Motivation

    ERIC Educational Resources Information Center

    Marashi, Hamid; Tahan-Shizari, Parissa

    2015-01-01

    This study was an attempt to investigate the comparative impact of convergent and divergent condition tasks on EFL learners' writing and motivation. Sixty female intermediate EFL learners were selected from among a total number of 90 through their performance on a sample piloted PET and further homogenized in terms of their writing and motivation.…

  2. First experience with early dynamic (18)F-NaF-PET/CT in patients with chronic osteomyelitis.

    PubMed

    Freesmeyer, Martin; Stecker, Franz F; Schierz, Jan-Henning; Hofmann, Gunther O; Winkens, Thomas

    2014-05-01

    This study investigates whether early dynamic positron emission tomography/computed tomography (edPET/CT) using (18)F-sodium fluoride-((18)F-NaF) is feasible in depicting early phases of radiotracer distribution in patients with chronic osteomyelitis (COM). A total of 12 ed(18)F-NaF-PET/CT examinations were performed on 11 consecutive patients (2 female, 9 male; age 53 ± 12 years) in list mode over 5 min starting with radiopharmaceutical injection before standard late (18)F-NaF-PET/CT. Eight consecutive time intervals (frames) were reconstructed for each patient: four 15 s, then four 60 s. Several volumes of interest (VOI) were selected, representing the affected area as well as different reference areas within the bone and soft tissue. Maximum and mean ed standardized uptake values (edSUVmax, edSUVmean, respectively) were calculated in each VOI during each frame to measure early fluoride influx and accumulation. Results were compared between affected and non-affected (contralateral) bones. Starting in the 31-45 s frame, the affected bone area showed significantly higher edSUVmax and edSUVmean compared to the healthy contralateral region. The affected bone areas also significantly differed from non-affected contralateral regions in conventional late (18)F-NaF-PET/CT. This pilot study suggests that, in patients with COM, ed(18)F-NaF -PET offers additional information about early radiotracer distribution to standard (18)F-NaF -PET/CT, similar to a three-phase bone scan. The results should be validated in larger trials which directly compare ed(18)F-NaF-PET to a three-phase bone scan.

  3. Evidence of Prostate-Specific Membrane Antigen Expression in Metastatic Differentiated Thyroid Cancer Using 68Ga-PSMA-HBED-CC PET/CT.

    PubMed

    Verma, Priyanka; Malhotra, Gaurav; Agrawal, Ritesh; Sonavane, Sunita; Meshram, Vilas; Asopa, Ramesh V

    2018-06-12

    Prostate-specific membrane antigen (PSMA) overexpression is not restricted to prostate cancer, but it has also been demonstrated in gliomas, lung cancer, and in tumor neovasculature. Systematic studies exploring PSMA uptake in thyroid tumors are lacking. The aim of this pilot study was to assess PSMA expression in patients with metastatic differentiated thyroid cancer (mDTC). Ten patients of mDTC harboring 32 lesions (5 men; age range, 38-65 years; mean age, 50 years) underwent prospective evaluation with radioiodine (I), F-FDG PET, and Ga-PSMA-HBED-CC PET scans as per the institution protocol. PSMA expression (SUVmax) was compared with F-FDG and I scan findings in all patients. Lesions were radioiodine avid in 8 patients, whereas 2 were classified as thyroglobulin elevation with negative iodide scintigraphy (TENIS) patients. All patients with iodine-avid metastatic disease showed substantial PSMA uptake. PSMA PET detected 30/32 total lesions (93.75%; SUVmax ranging from 4.86 to 101.81 with median SUVmax of 31.35), whereas FDG PET/CT was positive in 23/32 lesions (81.85%). Twenty-one (70%) of 30 lesions that showed PSMA expression were localized to the bones. PSMA localized a lesion in each of the 2 TENIS patients similar to FDG PET scan. Ga-PSMA-HBED-CC PET/CT is a potentially useful imaging modality in patients of mDTC with most (70%) of PSMA expressing metastasis being localized to the bones. PSMA PET/CT could be useful for identifying patients with limited therapeutic options (eg, TENIS) who might benefit from PSMA-targeted radionuclide therapy.

  4. Use of positron emission tomography scan response to guide treatment change for locally advanced gastric cancer: the Memorial Sloan Kettering Cancer Center experience.

    PubMed

    Won, Elizabeth; Shah, Manish A; Schöder, Heiko; Strong, Vivian E; Coit, Daniel G; Brennan, Murray F; Kelsen, David P; Janjigian, Yelena Y; Tang, Laura H; Capanu, Marinela; Rizk, Nabil P; Allen, Peter J; Bains, Manjit S; Ilson, David H

    2016-08-01

    Early metabolic response on 18-fluorodeoxyglucose-positron emission tomography (FDG-PET) during neoadjuvant chemotherapy is PET non-responders have poor outcomes whether continuing chemotherapy or proceeding directly to surgery. Use of PET may identify early treatment failure, sparing patients from inactive therapy and allowing for crossover to alternative therapies. We examined the effectiveness of PET directed switching to salvage chemotherapy in the PET non-responders. Patients with locally advanced resectable FDG-avid gastric or gastroesophageal junction (GEJ) adenocarcinoma received bevacizumab 15 mg/kg, epirubicin 50 mg/m(2), cisplatin 60 mg/m(2) day 1, and capecitabine 625 mg/m(2) bid (ECX) every 21 days. PET scan was obtained at baseline and after cycle 1. PET responders, (i.e., ≥35% reduction in FDG uptake at the primary tumor) continued ECX + bev. Non-responders switched to docetaxel 30 mg/m(2), irinotecan 50 mg/mg(2) day 1 and 8 plus bevacizumab every 21 days for 2 cycles. Patients then underwent surgery. The primary objective was to improve the 2-year disease free survival (DFS) from 30% (historical control) to 53% in the non-responders. Twenty evaluable patients enrolled before the study closed for poor accrual. Eleven were PET responders and the 9 non-responders switched to the salvage regimen. With a median follow-up of 38.2 months, the 2-year DFS was 55% [95% confidence interval (CI), 30-85%] in responders compared with 56% in the non-responder group (95% CI, 20-80%, P=0.93). The results suggest that changing chemotherapy regimens in PET non-responding patients may improve outcomes. Results from this pilot trial are hypothesis generating and suggest that PET directed neoadjuvant therapy merits evaluation in a larger trial.

  5. Quantification of myocardial blood flow using dynamic 320-row multi-detector CT as compared with ¹⁵O-H₂O PET.

    PubMed

    Kikuchi, Yasuka; Oyama-Manabe, Noriko; Naya, Masanao; Manabe, Osamu; Tomiyama, Yuuki; Sasaki, Tsukasa; Katoh, Chietsugu; Kudo, Kohsuke; Tamaki, Nagara; Shirato, Hiroki

    2014-07-01

    This study introduces a method to calculate myocardium blood flow (MBF) and coronary flow reserve (CFR) using the relatively low-dose dynamic 320-row multi-detector computed tomography (MDCT), validates the method against (15)O-H₂O positron-emission tomography (PET) and assesses the CFRs of coronary artery disease (CAD) patients. Thirty-two subjects underwent both dynamic CT perfusion (CTP) and PET perfusion imaging at rest and during pharmacological stress. In 12 normal subjects (pilot group), the calculation method for MBF and CFR was established. In the other 13 normal subjects (validation group), MBF and CFR obtained by dynamic CTP and PET were compared. Finally, the CFRs obtained by dynamic CTP and PET were compared between the validation group and CAD patients (n = 7). Correlation between MBF of MDCT and PET was strong (r = 0.95, P < 0.0001). CFR showed good correlation between dynamic CTP and PET (r = 0.67, P = 0.0126). CFRCT in the CAD group (2.3 ± 0.8) was significantly lower than that in the validation group (5.2 ± 1.8) (P = 0.0011). We established a method for measuring MBF and CFR with the relatively low-dose dynamic MDCT. Lower CFR was well demonstrated in CAD patients by dynamic CTP. • MBF and CFR can be calculated using dynamic CTP with 320-row MDCT. • MBF and CFR showed good correlation between dynamic CTP and PET. • Lower CFR was well demonstrated in CAD patients by dynamic CTP.

  6. Food and Food-Odor Preferences in Dogs: A Pilot Study

    PubMed Central

    Péron, Franck; Cambou, Stéphanie; Callejon, Laurence; Wynne, Clive D.L.

    2017-01-01

    Abstract Evaluation of food palatability and preference is of great importance to the pet food industry. One common technique for evaluating palatability is a 2-bowl test in which 2 products are offered simultaneously and food consumption is measured. This yields clear results with dogs trained to routinely conduct such comparisons, but it is less clear how this extends to untrained pet dogs. In addition, prior research indicates that olfaction is important in food preference, but methods for evaluating odor preference in canines are currently lacking. In this study, we developed a modified 2-bowl test for evaluation of food preferences in pet dogs with minimal training, and an olfactometer technique for the evaluation of odor preferences. In our 2-bowl procedure, we observed clear preferences among 4 commercial food products in 6 pet dogs. Across repeated testing, preferences strengthened, but the first evaluation accurately estimated the direction and significance of preference. In addition, dogs typically (89% of the time) consumed more of the food they chose first, suggesting they did not need to taste each food to choose. Our odor preference olfactometer assessment, however, did not reveal odor preferences other than that dogs preferred to sniff a food odor over clean air. Further work will be needed to identify methods of measuring odor preferences amongst food odors for dogs, but the modified 2-bowl test shows promise for further testing in pet dogs.

  7. Development and Validation of the Patient Experience with Treatment and Self-Management (PETS): A Patient-Reported Measure of Treatment Burden

    PubMed Central

    Eton, David T.; Yost, Kathleen J.; Lai, Jin-shei; Ridgeway, Jennifer L.; Egginton, Jason S.; Rosedahl, Jordan K.; Linzer, Mark; Boehm, Deborah H.; Thakur, Azra; Poplau, Sara; Odell, Laura; Montori, Victor M.; May, Carl R.; Anderson, Roger T.

    2017-01-01

    Purpose The purpose of this study was to develop and validate a new comprehensive patient-reported measure of treatment burden – the Patient Experience with Treatment and Self-Management (PETS). Methods A conceptual framework was used to derive the PETS with items reviewed and cognitively tested with patients. A survey battery, including a pilot version of the PETS, was mailed to 838 multi-morbid patients from two healthcare institutions for validation. Results A total of 332 multi-morbid patients returned completed surveys. Diagnostics supported deletion and consolidation of some items and domains. Confirmatory factor analysis supported a domain model for scaling comprised of 9 factors: medical information, medications, medical appointments, monitoring health, interpersonal challenges, medical/healthcare expenses, difficulty with healthcare services, role/social activity limitations, and physical/mental exhaustion. Scales showed good internal consistency (alpha range: 0.79 – 0.95). Higher PETS scores, indicative of greater treatment burden, were correlated with more distress, less satisfaction with medications, lower self-efficacy, worse physical and mental health, and lower convenience of healthcare (Ps<.001). Patients with lower health literacy, less adherence to medications, and more financial difficulties reported higher PETS scores (Ps<.01). Conclusion A comprehensive patient-reported measure of treatment burden can help to better characterize the impact of treatment and self-management burden on patient well-being and guide care toward minimally disruptive medicine. PMID:27566732

  8. Development and validation of the Patient Experience with Treatment and Self-management (PETS): a patient-reported measure of treatment burden.

    PubMed

    Eton, David T; Yost, Kathleen J; Lai, Jin-Shei; Ridgeway, Jennifer L; Egginton, Jason S; Rosedahl, Jordan K; Linzer, Mark; Boehm, Deborah H; Thakur, Azra; Poplau, Sara; Odell, Laura; Montori, Victor M; May, Carl R; Anderson, Roger T

    2017-02-01

    The purpose of this study was to develop and validate a new comprehensive patient-reported measure of treatment burden-the Patient Experience with Treatment and Self-management (PETS). A conceptual framework was used to derive the PETS with items reviewed and cognitively tested with patients. A survey battery, including a pilot version of the PETS, was mailed to 838 multi-morbid patients from two healthcare institutions for validation. A total of 332 multi-morbid patients returned completed surveys. Diagnostics supported deletion and consolidation of some items and domains. Confirmatory factor analysis supported a domain model for scaling comprised of 9 factors: medical information, medications, medical appointments, monitoring health, interpersonal challenges, medical/healthcare expenses, difficulty with healthcare services, role/social activity limitations, and physical/mental exhaustion. Scales showed good internal consistency (α range 0.79-0.95). Higher PETS scores, indicative of greater treatment burden, were correlated with more distress, less satisfaction with medications, lower self-efficacy, worse physical and mental health, and lower convenience of healthcare (Ps < 0.001). Patients with lower health literacy, less adherence to medications, and more financial difficulties reported higher PETS scores (Ps < 0.01). A comprehensive patient-reported measure of treatment burden can help to better characterize the impact of treatment and self-management burden on patient well-being and guide care toward minimally disruptive medicine.

  9. (18)F-FDG PET/CT, cytoreductive surgery and intraperitoneal chemohyperthermia for the therapeutic management in peritoneal carcinomatosis: A pilot study.

    PubMed

    Cistaro, A; Cucinotta, M; Cassalia, L; Priola, A; Priola, S; Pappalardo, M; Coppolino, P; De Simone, M; Quartuccio, N

    2016-01-01

    Peritoneal carcinomatosis is a common evolution of neoplasms and the terminal stage of disease. A new therapeutic technique, based on the total surgical removal of peritoneal lesions (peritonectomy procedure - PP) combined with the intraperitoneal chemohyperthermia (IPCH), has been developed. Proper patient selection is mandatory for optimizing the results of treatment. The aim of this study was to investigate the role of [(18)F]fluoro-2-deoxy-d-glucose Positron Emission Tomography/Computed Tomography ((18)F-FDG PET/CT) in patients with peritoneal carcinosis selected to undergo PP and IPCH. Furthermore, we aimed to identify characteristic patterns of abdominal(18)F-FDG uptake and to correlate these patterns with available anatomic findings after surgery. Patients with either histologically confirmed peritoneal carcinosis or suspected upon clinical follow-up and/or imaging findings were prospectively submitted to pre-surgery (18)F-FDG PET/CT scan. Only those patients without evidence of extra-peritoneal metastases at PET/CT scan were treated with PP and IPCH. 11 patients with peritoneal carcinomatosis (5 colorectal, 4 ovarian, 1 pancreatic) and 1 unknown primitive cancer, were eligible for the study. In all cases PET/CT scan showed multiple peritoneal implants. In 6 out of 11 cases (54%) metastases were evidenced by (18)F-FDG PET/CT: 2 cases with liver metastases; 1 case with bone metastases; 3 patients with lymph-node lesions. Two distinct imaging patterns, with focal or diffuse increased (18)F-FDG uptake, were recognized. PP+IPCH of patients selected by (18)F-FDG PET/CT seems to be safe and feasible. PET/CT scan appears as a reliable tool for the detection, characterization of peritoneal implants with potential impact in the therapeutic management of these patients. Copyright © 2016 Elsevier España, S.L.U. and SEMNIM. All rights reserved.

  10. Pilot Study of 64Cu(I) for PET Imaging of Melanoma

    DOE PAGES

    Jiang, Lei; Tu, Yingfeng; Hu, Xiang; ...

    2017-05-31

    Currently, 64Cu(II) labeled tracers including 64CuCl 2 have been widely applied in the research of molecular imaging and therapy. Human copper transporter 1 (hCTR1) is the major high affinity copper influx transporter in mammalian cells, and specially responsible for the transportation of Cu(I) not Cu(II). Thus, we investigated the feasible application of 64Cu(I) for PET imaging. 64Cu(II) was reduced to 64Cu(I) with the existence of sodium L-ascorbate, DL-Dithiothreitol or cysteine. Cell uptake and efflux assay was investigated using B16F10 and A375 cell lines, respectively. Small animal PET and biodistribution studies were performed in both B16F10 and A375 tumor-bearing mice. Comparedmore » with 64Cu(II), 64Cu(I) exhibited higher cellular uptake by melanoma, which testified CTR1 specially influx of Cu(I). But, due to oxidation reaction in vivo, no significant difference between 64Cu(I) and 64Cu(II) was observed through PET images and biodistribution. In addition, radiation absorbed doses for major tissues of human were calculated based on the mouse biodistribution. Radiodosimetry calculations for 64/67Cu(I) and 64/67Cu(II) were similar, which suggested that although melanoma were with high radiation absorbed doses, high radioactivity accumulation by liver and kidney should be noticed for the further application. Thus, 64Cu(I) should be further studied to evaluate it as a PET imaging radiotracer.« less

  11. Pilot Study of 64Cu(I) for PET Imaging of Melanoma

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jiang, Lei; Tu, Yingfeng; Hu, Xiang

    Currently, 64Cu(II) labeled tracers including 64CuCl 2 have been widely applied in the research of molecular imaging and therapy. Human copper transporter 1 (hCTR1) is the major high affinity copper influx transporter in mammalian cells, and specially responsible for the transportation of Cu(I) not Cu(II). Thus, we investigated the feasible application of 64Cu(I) for PET imaging. 64Cu(II) was reduced to 64Cu(I) with the existence of sodium L-ascorbate, DL-Dithiothreitol or cysteine. Cell uptake and efflux assay was investigated using B16F10 and A375 cell lines, respectively. Small animal PET and biodistribution studies were performed in both B16F10 and A375 tumor-bearing mice. Comparedmore » with 64Cu(II), 64Cu(I) exhibited higher cellular uptake by melanoma, which testified CTR1 specially influx of Cu(I). But, due to oxidation reaction in vivo, no significant difference between 64Cu(I) and 64Cu(II) was observed through PET images and biodistribution. In addition, radiation absorbed doses for major tissues of human were calculated based on the mouse biodistribution. Radiodosimetry calculations for 64/67Cu(I) and 64/67Cu(II) were similar, which suggested that although melanoma were with high radiation absorbed doses, high radioactivity accumulation by liver and kidney should be noticed for the further application. Thus, 64Cu(I) should be further studied to evaluate it as a PET imaging radiotracer.« less

  12. Comparison of O-(2-18F-Fluoroethyl)-L-Tyrosine Positron Emission Tomography and Perfusion-Weighted Magnetic Resonance Imaging in the Diagnosis of Patients with Progressive and Recurrent Glioma: A Hybrid Positron Emission Tomography/Magnetic Resonance Study.

    PubMed

    Verger, Antoine; Filss, Christian P; Lohmann, Philipp; Stoffels, Gabriele; Sabel, Michael; Wittsack, Hans-J; Kops, Elena Rota; Galldiks, Norbert; Fink, Gereon R; Shah, Nadim J; Langen, Karl-Josef

    2018-05-01

    To compare the diagnostic performance of O-(2- 18 F-fluoroethyl)-L-tyrosine ( 18 F-FET) positron emission tomography (PET) and perfusion-weighted magnetic resonance imaging (PWI) for the diagnosis of progressive or recurrent glioma. Thirty-two pretreated gliomas (25 progressive or recurrent tumors, 7 treatment-related changes) were investigated with 18 F-FET PET and PWI via a hybrid PET/magnetic resonance scanner. Volumes of interest with a diameter of 16 mm were centered on the maximum of abnormality in the tumor area in PET and PWI maps (relative cerebral blood volume, relative cerebral blood flow, mean transit time) and the contralateral unaffected hemisphere. Mean and maximum tumor-to-brain ratios as well as dynamic data for 18 F-FET uptake were calculated. Diagnostic accuracies were evaluated by receiver operating characteristic analyses, calculating the area under the curve. 18 F-FET PET showed a significant greater sensitivity to detect abnormalities in pretreated gliomas than PWI (76% vs. 52%, P = 0.03). The maximum tumor-to-brain ratio of 18 F-FET PET was the only parameter that discriminated treatment-related changes from progressive or recurrent gliomas (area under the curve, 0.78; P = 0.03, best cut-off 2.61; sensitivity 80%, specificity 86%, accuracy 81%). Among patients with signal abnormality in both modalities, 75% revealed spatially incongruent local hot spots. This pilot study suggests that 18 F-FET PET is superior to PWI to diagnose progressive or recurrent glioma. Copyright © 2018 Elsevier Inc. All rights reserved.

  13. Fluorine-18-fluorocholine PET/CT parameters predictive for hematological toxicity to radium-223 therapy in castrate-resistant prostate cancer patients with bone metastases: a pilot study.

    PubMed

    Vija Racaru, Lavinia; Sinigaglia, Mathieu; Kanoun, Salim; Ben Bouallègue, Fayçal; Tal, Ilan; Brillouet, Sévérine; Bauriaud-Mallet, Mathilde; Zerdoud, Slimane; Dierickx, Lawrence; Vallot, Delphine; Caselles, Olivier; Gabiache, Erwan; Pascal, Pierre; Courbon, Frederic

    2018-05-21

    This study aims to predict hematological toxicity induced by Ra therapy. We investigated the value of metabolically active bone tumor volume (MBTV) and total bone lesion activity (TLA) calculated on pretreatment fluorine-18-fluorocholine (F-FCH) PET/CT in castrate-resistant prostate cancer (CRPC) patients with bone metastases treated with Ra radionuclide therapy. F-FCH PET/CT imaging was performed in 15 patients with CRPC before treatment with Ra. Bone metastatic disease was quantified on the basis of the maximum standardized uptake value (SUV), total lesion activity (TLA=MBTV×SUVmean), or MBTV/height (MBTV/H) and TLA/H. F-FCH PET/CT bone tumor burden and activity were analyzed to identify which parameters could predict hematological toxicity [on hemoglobin (Hb), platelets (PLTs), and lymphocytes] while on Ra therapy. Pearson's correlation was used to identify the correlations between age, prostate-specific antigen, and F-FCH PET parameters. MBTV ranged from 75 to 1259 cm (median: 392 cm). TLA ranged from 342 to 7198 cm (median: 1853 cm). Patients benefited from two to six cycles of Ra (n=56 cycles in total). At the end of Ra therapy, five of the 15 (33%) patients presented grade 2/3 toxicity on Hb and lymphocytes, whereas three of the 15 (20%) patients presented grade 2/3 PLT toxicity.Age was correlated negatively with both MBTV (r=-0.612, P=0.015) and TLA (r=-0.596, P=0.018). TLA, TLA/H, and MBTV/H predicted hematological toxicity on Hb, whereas TLA/H and MBTV/H predicted toxicity on PLTs at the end of Ra cycles. Receiver operating characteristic curve analysis allowed to define the cutoffs for MBTV (915 cm) and TLA (4198 cm) predictive for PLT toxicity, with an accuracy of 0.92 and 0.99. Tumor bone burden calculation is feasible with F-FCH PET/CT with freely available open-source software. In this pilot study, baseline F-FCH PET/CT markers (TLA, MBTV) have shown abilities to predict Hb and PLT toxicity after Ra therapy and could be explored for patient selection and treatment optimization.This is an open-access article distributed under the terms of the Creative Commons Attribution-Non Commercial-No Derivatives License 4.0 (CCBY-NC-ND), where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially without permission from the journal. http://creativecommons.org/licenses/by-nc-nd/4.0/.

  14. On the effectiveness of ion range determination from in-beam PET data

    NASA Astrophysics Data System (ADS)

    Fiedler, Fine; Shakirin, Georgy; Skowron, Judith; Braess, Henning; Crespo, Paulo; Kunath, Daniela; Pawelke, Jörg; Pönisch, Falk; Enghardt, Wolfgang

    2010-04-01

    At present, in-beam positron emission tomography (PET) is the only method for in vivo and in situ range verification in ion therapy. At the GSI Helmholtzzentrum für Schwerionenforschung GmbH (GSI) Darmstadt, Germany, a unique in-beam PET installation has been operated from 1997 until the shut down of the carbon ion therapy facility in 2008. Therapeutic irradiation by means of 12C ion beams of more than 400 patients have been monitored. In this paper a first quantitative study on the accuracy of the in-beam PET method to detect range deviations between planned and applied treatment in clinically relevant situations using simulations based on clinical data is presented. Patient treatment plans were used for performing simulations of positron emitter distributions. For each patient a range difference of ± 6 mm in water was applied and compared to simulations without any changes. The comparisons were performed manually by six experienced evaluators for data of 81 patients. The number of patients required for the study was calculated using the outcome of a pilot study. The results indicate a sensitivity of (91 ± 3)% and a specificity of (96 ± 2)% for detecting an overrange, a reduced range is recognized with a sensitivity of (92 ± 3)% and a specificity of (96 ± 2)%. The positive and the negative predictive value of this method are 94% and 87%, respectively. The interobserver coefficient of variation is between 3 and 8%. The in-beam PET method demonstrated a high sensitivity and specificity for the detection of range deviations. As the range is a most indicative factor of deviations in the dose delivery, the promising results shown in this paper confirm the in-beam PET method as an appropriate tool for monitoring ion therapy.

  15. Quantitative graphical analysis of simultaneous dynamic PET/MRI for assessment of prostate cancer.

    PubMed

    Rosenkrantz, Andrew B; Koesters, Thomas; Vahle, Anne-Kristin; Friedman, Kent; Bartlett, Rachel M; Taneja, Samir S; Ding, Yu-Shin; Logan, Jean

    2015-04-01

    Dynamic FDG imaging for prostate cancer characterization is limited by generally small size and low uptake in prostate tumors. Our aim in this pilot study was to explore feasibility of simultaneous PET/MRI to guide localization of prostate lesions for dynamic FDG analysis using a graphical approach. Three patients with biopsy-proven prostate cancer underwent simultaneous FDG PET/MRI, incorporating dynamic prostate imaging. Histology and multiparametric MRI findings were used to localize tumors, which in turn guided identification of tumors on FDG images. Regions of interest were manually placed on tumor and benign prostate tissue. Blood activity was extracted from a region of interest placed on the femoral artery on PET images. FDG data were analyzed by graphical analysis using the influx constant Ki (Patlak analysis) when FDG binding seemed irreversible and distribution volume VT (reversible graphical analysis) when FDG binding seemed reversible given the presence of washout. Given inherent coregistration, simultaneous acquisition facilitated use of MRI data to localize small lesions on PET and subsequent graphical analysis in all cases. In 2 cases with irreversible binding, tumor had higher Ki than benign using Patlak analysis (0.023 vs 0.006 and 0.019 vs 0.008 mL/cm3 per minute). In 1 case appearing reversible, tumor had higher VT than benign using reversible graphical analysis (0.68 vs 0.52 mL/cm3). Simultaneous PET/MRI allows localization of small prostate tumors for dynamic PET analysis. By taking advantage of inclusion of the femoral arteries in the FOV, we applied advanced PET data analysis methods beyond conventional static measures and without blood sampling.

  16. Evaluation of tumor hypoxia prior to radiotherapy in intermediate-risk prostate cancer using 18F-fluoromisonidazole PET/CT: a pilot study.

    PubMed

    Supiot, Stéphane; Rousseau, Caroline; Dore, Mélanie; Cheze-Le-Rest, Catherine; Kandel-Aznar, Christine; Potiron, Vincent; Guerif, Stéphane; Paris, François; Ferrer, Ludovic; Campion, Loïc; Meingan, Philippe; Delpon, Gregory; Hatt, Mathieu; Visvikis, Dimitris

    2018-02-09

    Hypoxia is a major factor in prostate cancer aggressiveness and radioresistance. Predicting which patients might be bad candidates for radiotherapy may help better personalize treatment decisions in intermediate-risk prostate cancer patients. We assessed spatial distribution of 18 F-Misonidazole (FMISO) PET/CT uptake in the prostate prior to radiotherapy treatment. Intermediate-risk prostate cancer patients about to receive high-dose (>74 Gy) radiotherapy to the prostate without hormonal treatment were prospectively recruited between 9/2012 and 10/2014. Prior to radiotherapy, all patients underwent a FMISO PET/CT as well as a MRI and 18 F-choline-PET. 18 F-choline and FMISO-positive volumes were semi-automatically determined using the fuzzy locally adaptive Bayesian (FLAB) method. In FMISO-positive patients, a dynamic analysis of early tumor uptake was performed. Group differences were assessed using the Wilcoxon signed rank test. Parameters were correlated using Spearman rank correlation. Of 27 patients (median age 76) recruited to the study, 7 and 9 patients were considered positive at 2.5h and 3.5h FMISO PET/CT respectively. Median SUV max and SUV max tumor to muscle (T/M) ratio were respectively 3.4 and 3.6 at 2.5h, and 3.2 and 4.4 at 3.5h. The median FMISO-positive volume was 1.1 ml. This is the first study regarding hypoxia imaging using FMISO in prostate cancer showing that a small FMISO-positive volume was detected in one third of intermediate-risk prostate cancer patients.

  17. Targeted Therapy and Immunotherapy Response Assessment with F-18 Fluorothymidine Positron-Emission Tomography/Magnetic Resonance Imaging in Melanoma Brain Metastasis: A Pilot Study.

    PubMed

    Nguyen, Nghi C; Yee, Melissa K; Tuchayi, Abuzar M; Kirkwood, John M; Tawbi, Hussein; Mountz, James M

    2018-01-01

    This pilot study aimed at exploring the utility of the proliferation tracer F-18 fluorothymidine (FLT) and positron-emission tomography (PET)/magnetic resonance imaging (MRI) (FLT-PET/MRI) for early treatment monitoring in patients with melanoma brain metastasis (MBM) who undergo targeted therapy or immunotherapy. Patients with newly diagnosed MBM underwent baseline and follow-up FLT-PET/MRI scans at 3-4 weeks of targeted therapy or immunotherapy. Up to six measurable brain lesions ≥1.0 cm per subject, as identified on T1-weighted post-gadolinium images, were included for quantitative analyses. The maximum SUV of each lesion was divided by the mean SUV of the pons to obtain the SUV ratio (SUVR). Five enrolled subjects underwent the baseline FLT-PET/MRI study in which the MBM showed a median size of 1.7 cm (range 1.0-2.9) and increased metabolic activity with SUVR of 9.9 (range 3.2-18.4). However, only two subjects (cases #1 and #2) returned for a follow-up scan. At baseline, a total of 22 lesions were analyzed in all five subjects, which showed a median size of 1.7 cm (range 1.0-2.9) and median SUVR of 9.9 (range 3.2-18.4). At follow-up, case #1 was a 55-year-old man who received targeted BRAF inhibitor and MEK inhibitor therapy with dabrafenib and trametinib. Fused PET/MRI data of six measured lesions demonstrated a significant reduction in MBM proliferative activity (median -68%; range -38 to -77%) and size (median -23%; range -4 to -55%) at three weeks of therapy. Nevertheless, the subject eventually progressed and died 13 months after therapy initiation. Case #2 was a 36-year-old man who received immunotherapy with nivolumab and ipilimumab. The five measured MBM lesions showed a mixed response at both proliferative and morphologic imaging at 1-month follow-up. Some lesions demonstrated interval decrease while others interval increase in proliferative activity with a median -44% (range -77 to +68%). On MRI, the size change was +7% (range -64 to +50%). The therapy was switched to dabrafenib and trametinib, which led to a partial response. The patient is still alive 16 months following therapy initiation. The five cases presented show the potential benefit of hybrid FLT-PET/MRI for the diagnosis of MBM and treatment monitoring of targeted therapy and immunotherapy. However, further studies are required to assess their complementary role in distinguishing true progression from pseudoprogression.

  18. Rifaximin suppresses background intestinal 18F-FDG uptake on PET/CT scans.

    PubMed

    Franquet, Elisa; Palmer, Mathew R; Gifford, Anne E; Selen, Daryl J; Chen, Yih-Chieh S; Sedora-Roman, Neda; Joyce, Robin M; Kolodny, Gerald M; Moss, Alan C

    2014-10-01

    Identification of cancer or inflammatory bowel disease in the intestinal tract by PET/computed tomography (CT) imaging can be hampered by physiological uptake of F-fluorodeoxyglucose (F-FDG) in the normal colon. Previous work has localized this F-FDG uptake to the intestinal lumen, predominantly occupied by bacteria. We sought to determine whether pretreatment with an antibiotic could reduce F-FDG uptake in the healthy colon. Thirty patients undergoing restaging PET/CT for nongastrointestinal lymphoma were randomly selected to receive rifaximin 550 mg twice daily for 2 days before their scan (post-rifaximin). Their PET/CT images were compared with those from their prior study (pre-rifaximin). Cecal maximum standard uptake value (SUVmax) and overall colonic F-FDG uptake were compared between scans. All PET/CT images were blindly scored by a radiologist. The same comparison of sequential scans was also undertaken in 30 patients who did not receive antibiotics. Thirty post-rifaximin scans were compared with 30 pre-rifaximin scans in the same patients. SUVmax in the cecum was significantly lower in the patient's post-rifaximin scans than in their pre-rifaximin scans (P=0.002). The percentage of scans with greater than grade 1 colonic F-FDG uptake was significantly lower in the post-rifaximin scans than in the pre-rifaximin scans (P<0.05). In contrast, there was no significant difference in the paired sequential scans from control patients, nor a reduction in the percentage of scans with greater than grade 1 colonic F-FDG uptake. This pilot study shows that treatment with rifaximin for 2 days before PET/CT scanning can significantly reduce physiological F-FDG uptake in the normal colonic lumen.

  19. A high 18F-FDOPA uptake is associated with a slow growth rate in diffuse Grade II-III gliomas.

    PubMed

    Isal, Sibel; Gauchotte, Guillaume; Rech, Fabien; Blonski, Marie; Planel, Sophie; Chawki, Mohammad B; Karcher, Gilles; Marie, Pierre-Yves; Taillandier, Luc; Verger, Antoine

    2018-04-01

    In diffuse Grade II-III gliomas, a high 3,4-dihydroxy-6-( 18 F)-fluoro-L-phenylalanine ( 18 F-FDOPA) positron emission tomography (PET) uptake, with a standardized uptake value (SUV max )/contralateral brain tissue ratio greater than 1.8, was previously found to be consistently associated with the presence of an isocitrate dehydrogenase (IDH) mutation, whereas this mutation is typically associated with a better prognosis. This pilot study was aimed to ascertain the prognostic value of this high 18 F-FDOPA uptake in diffuse Grade II-III gliomas with regard to the velocity of diameter expansion (VDE), which represents an established landmark of better prognosis when below 4 mm per year. 20 patients (42 ± 10 years, 10 female) with newly-diagnosed diffuse Grade II-III gliomas (17 with IDH mutation) were retrospectively included. All had a 18 F-FDOPA PET, quantified with SUV max ratio, along with a serial MRI enabling VDE determination. SUV max ratio was above 1.8 in 5 patients (25%) all of whom had a VDE <4 mm/year (100%) and IDH mutation (100%). Moreover, a SUV max ratio above 1.8 was associated with higher rates of VDE <4 mm/year in the overall population (45 vs 0%, p = 0.04) and also in the subgroup of patients with IDH mutation (45 vs 0%, p = 0.10). This pilot study shows that in diffuse Grade II-III gliomas, a high 18 F-FDOPA uptake would be predictive of low tumour growth, with a different prognostic significance than IDH mutation. Advances in knowledge: 18 F-FDOPA PET in a single session imaging could have prognostic value in initial diagnosis of diffuse Grade II-III gliomas.

  20. Effects of ferumoxytol on quantitative PET measurements in simultaneous PET/MR whole-body imaging: a pilot study in a baboon model.

    PubMed

    Borra, Ronald Jh; Cho, Hoon-Sung; Bowen, Spencer L; Attenberger, Ulrike; Arabasz, Grae; Catana, Ciprian; Josephson, Lee; Rosen, Bruce R; Guimaraes, Alexander R; Hooker, Jacob M

    2015-12-01

    Simultaneous PET/MR imaging depends on MR-derived attenuation maps (mu-maps) for accurate attenuation correction of PET data. Currently, these maps are derived from gradient-echo-based MR sequences, which are sensitive to susceptibility changes. Iron oxide magnetic nanoparticles have been used in the measurement of blood volume, tumor microvasculature, tumor-associated macrophages, and characterizing lymph nodes. Our aim in this study was to assess whether the susceptibility effects associated with iron oxide nanoparticles can potentially affect measured (18)F-FDG PET standardized uptake values (SUV) through effects on MR-derived attenuation maps. The study protocol was approved by the Institutional Animal Care and Use Committee. Using a Siemens Biograph mMR PET/MR scanner, we evaluated the effects of increasing concentrations of ferumoxytol and ferumoxytol aggregates on MR-derived mu-maps using an agarose phantom. In addition, we performed a baboon experiment evaluating the effects of a single i.v. ferumoxytol dose (10 mg/kg) on the liver, spleen, and pancreas (18)F-FDG SUV at baseline (ferumoxytol-naïve), within the first hour and at 1, 3, 5, and 11 weeks. Phantom experiments showed mu-map artifacts starting at ferumoxytol aggregate concentrations of 10 to 20 mg/kg. The in vivo baboon data demonstrated a 53% decrease of observed (18)F-FDG SUV compared to baseline within the first hour in the liver, persisting at least 11 weeks. A single ferumoxytol dose can affect measured SUV for at least 3 months, which should be taken into account when administrating ferumoxytol in patients needing sequential PET/MR scans. Advances in knowledge 1. Ferumoxytol aggregates, but not ferumoxytol alone, produce significant artifacts in MR-derived attenuation correction maps at approximate clinical dose levels of 10 mg/kg. 2. When performing simultaneous whole-body (18)F-FDG PET/MR, a single dose of ferumoxytol can result in observed SUV decreases up to 53%, depending on the amount of ferumoxytol aggregates in the studied tissue. Implications for patient care Administration of a single, clinically relevant, dose of ferumoxytol can potentially result in changes in observed SUV for a prolonged period of time in the setting of simultaneous PET/MR. These potential changes should be considered in particular when administering ferumoxytol to patients with expected future PET/MR studies, as ferumoxytol-induced SUV changes might interfere with therapy assessment.

  1. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang, P; Kuo, L; Yorke, E

    Purpose: To develop a biological modeling strategy which incorporates the response observed on the mid-treatment PET/CT into a dose escalation design for adaptive radiotherapy of non-small-cell lung cancer. Method: FDG-PET/CT was acquired midway through standard fractionated treatment and registered to pre-treatment planning PET/CT to evaluate radiation response of lung cancer. Each mid-treatment PET voxel was assigned the median SUV inside a concentric 1cm-diameter sphere to account for registration and imaging uncertainties. For each voxel, the planned radiation dose, pre- and mid-treatment SUVs were used to parameterize the linear-quadratic model, which was then utilized to predict the SUV distribution after themore » full prescribed dose. Voxels with predicted post-treatment SUV≥2 were identified as the resistant target (response arm). An adaptive simultaneous integrated boost was designed to escalate dose to the resistant target as high as possible, while keeping prescription dose to the original target and lung toxicity intact. In contrast, an adaptive target volume was delineated based only on the intensity of mid-treatment PET/CT (intensity arm), and a similar adaptive boost plan was optimized. The dose escalation capability of the two approaches was compared. Result: Images of three patients were used in this planning study. For one patient, SUV prediction indicated complete response and no necessary dose escalation. For the other two, resistant targets defined in the response arm were multifocal, and on average accounted for 25% of the pre-treatment target, compared to 67% in the intensity arm. The smaller response arm targets led to a 6Gy higher mean target dose in the adaptive escalation design. Conclusion: This pilot study suggests that adaptive dose escalation to a biologically resistant target predicted from a pre- and mid-treatment PET/CT may be more effective than escalation based on the mid-treatment PET/CT alone. More plans and ultimately clinical protocols are needed to validate this approach. MSKCC has a research agreement with Varian Medical System.« less

  2. A pilot study on the correlation between fat fraction values and glucose uptake values in supraclavicular fat by simultaneous PET/MRI.

    PubMed

    McCallister, Andrew; Zhang, Le; Burant, Alex; Katz, Laurence; Branca, Rosa Tamara

    2017-11-01

    To assess the spatial correlation between MRI and 18F-fludeoxyglucose positron emission tomography (FDG-PET) maps of human brown adipose tissue (BAT) and to measure differences in fat fraction (FF) between glucose avid and non-avid regions of the supraclavicular fat depot using a hybrid FDG-PET/MR scanner. In 16 healthy volunteers, mean age of 30 and body mass index of 26, FF, R2*, and FDG uptake maps were acquired simultaneously using a hybrid PET/MR system while employing an individualized cooling protocol to maximally stimulate BAT. Fourteen of the 16 volunteers reported BAT-positive FDG-PET scans. MR FF maps of BAT correlate well with combined FDG-PET/MR maps of BAT only in subjects with intense glucose uptake. The results indicate that the extent of the spatial correlation positively correlates with maximum FDG uptake in the supraclavicular fat depot. No consistent, significant differences were found in FF or R2* between FDG avid and non-avid supraclavicular fat regions. In a few FDG-positive subjects, a small but significant linear decrease in BAT FF was observed during BAT stimulation. MR FF, when used in conjunction with FDG uptake maps, can be seen as a valuable, radiation-free alternative to CT and can be used to measure tissue hydration and lipid consumption in some subjects. Magn Reson Med 78:1922-1932, 2017. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  3. 5-HT2 receptor distribution shown by [18F] setoperone PET in high-functioning autistic adults.

    PubMed

    Beversdorf, David Q; Nordgren, Richard E; Bonab, Ali A; Fischman, Alan J; Weise, Steven B; Dougherty, Darin D; Felopulos, Gretchen J; Zhou, Feng C; Bauman, Margaret L

    2012-01-01

    The serotonergic system is implicated in disordered emotional behavior. Autism is characterized by impaired processing of emotional information. The serotonergic (5-HT) system is also critically involved in brain development, and abnormal brain synthesis of serotonin is observed in autism. Furthermore, whole blood and platelet serotonin have been reported to be elevated in autism. The authors examined the CNS serotonin system in autism in vivo. 5-HT2 receptors were visualized by PET imaging of [18F]setoperone-binding in this pilot study of 6 high-functioning autistic adults and 10 matched-control participants. Autism subjects had less thalamic [18F]setoperone binding than controls, when covaried for age, but no difference reached significance in other areas. A negative relationship between thalamic binding and history of language impairment was also observed. Further studies will be needed to gain a clearer picture of the role of the 5-HT system in autism.

  4. Metabolic effects of pulmonary obstruction on myocardial functioning: a pilot study using multiple time-point 18F-FDG-PET imaging.

    PubMed

    Choi, Grace G; Han, Yuchi; Weston, Brian; Ciftci, Esra; Werner, Thomas J; Torigian, Drew; Salavati, Ali; Alavi, Abass

    2015-01-01

    The aim of this study was to evaluate fluorine-18 fluorodeoxyglucose (18F-FDG) uptake in the right ventricle (RV) of patients with chronic obstructive pulmonary disease (COPD) and to characterize the variability of 18F-FDG uptake in the RV at different time points following radiotracer administration using PET/computerized tomography (CT). Impaired RV systolic function, RV hypertrophy, and RV dilation are associated with increases in mean pulmonary arterial pressure in patients with COPD. Metabolic changes in the RV using 18F-FDG-PET images 2 and 3 h after tracer injection have not yet been investigated. Twenty-five patients with clinical suspicion of lung cancer underwent 18F-FDG-PET/CT imaging at 1, 2, and 3 h after tracer injection. Standardized uptake values (SUVs) and volumes of RV were recorded from transaxial sections to quantify the metabolic activity. The SUV of RV was higher in patients with COPD stages 1-3 as compared with that in patients with COPD stage 0. RV SUV was inversely correlated with FEV1/FVC pack-years of smoking at 1 h after 18F-FDG injection. In the majority of patients, 18F-FDG activity in RV decreased over time. There was no significant difference in the RV myocardial free wall and chamber volume on the basis of COPD status. The severity of lung obstruction and pack-years of smoking correlate with the level of 18F-FDG uptake in the RV myocardium, suggesting that there may be metabolic changes in the RV associated with lung obstruction that can be detected noninvasively using 18F-FDG-PET/CT. Multiple time-point images of the RV did not yield any additional value in this study.

  5. Microglia activation in multiple sclerosis black holes predicts outcome in progressive patients: an in vivo [(11)C](R)-PK11195-PET pilot study.

    PubMed

    Giannetti, Paolo; Politis, Marios; Su, Paul; Turkheimer, Federico; Malik, Omar; Keihaninejad, Shiva; Wu, Kit; Reynolds, Richard; Nicholas, Richard; Piccini, Paola

    2014-05-01

    The pathophysiological correlates and the contribution to persisting disability of hypointense T1-weighted MRI lesions, black holes (BH), in multiple sclerosis (MS) are still unclear. In order to study the in vivo functional correlates of this MRI finding, we used 11C-PK11195 PET (PK-PET) to investigate changes in microglial activity. Ten relapsing and 9 progressive MS subjects had a PK-PET scan and a MRI scan alongside a full clinical assessment, including the expanded disability status scale (EDSS) for evaluation of disability. We studied the PK binding potential of the specifically bound radioligand relative to the non-displaceable radioligand in tissue (BPND) in T1 BHs. Out of a total of 1242 BHs identified, 947 were PK enhancing. The PKBPND was correlated with the EDSS (r=0.818; p<0.05) only in the progressive group. In the relapsing patients there was an inverse correlation between PKBPND and BH total lesion volume in whole brain (r=-0.781; p<0.05). When progressive patients were grouped according to the disability outcome at 2years from the PK-PET scan, the total PKBPND in BHs was found to be a significant outcome predictor of disability (p<0.01). Our findings show that relapsing and progressive patients have heterogeneous patterns of PKBPND in T1 BHs and indicate that BHs are not just "holes" representing loss of axons and myelin, but display inflammatory activity in the form of activated microglia. The significant association between PKBPND, neurological impairment and outcome in progressive subjects supports a role for activated microglia in disability progression. Copyright © 2014 Elsevier Inc. All rights reserved.

  6. Changes in Cervical Cancer FDG Uptake During Chemoradiation and Association With Response

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kidd, Elizabeth A., E-mail: ekidd@stanford.edu; Thomas, Maria; Siegel, Barry A.

    2013-01-01

    Purpose: Previous research showed that pretreatment uptake of F-18 fluorodeoxyglucose (FDG), as assessed by the maximal standardized uptake value (SUV{sub max}) and the variability of uptake (FDG{sub hetero}), predicted for posttreatment response in cervical cancer. In this pilot study, we evaluated the changes in SUV{sub max} and FDG{sub hetero} during concurrent chemoradiation for cervical cancer and their association with post-treatment response. Methods and Materials: Twenty-five patients with stage Ib1-IVa cervical cancer were enrolled. SUV{sub max}, FDG{sub hetero}, and metabolic tumor volume (MTV) were recorded from FDG-positron emission tomography (PET)/computed tomography (CT) scans performed pretreatment and during weeks 2 and 4more » of treatment and were evaluated for changes and association with response assessed on 3-month post-treatment FDG-PET/CT. Results: For all patients, the average pretreatment SUV{sub max} was 17.8, MTV was 55.4 cm{sup 3}, and FDG{sub hetero} was -1.33. A similar decline in SUV{sub max} was seen at week 2 compared with baseline and week 4 compared with week 2 (34%). The areas of highest FDG uptake in the tumor remained relatively consistent on serial scans. Mean FDG{sub hetero} decreased during treatment. For all patients, MTV decreased more from week 2 to week 4 than from pretreatment to week 2. By week 4, the average SUV{sub max} had decreased by 57% and the MTV had decreased by 30%. Five patients showed persistent or new disease on 3-month post-treatment PET. These poor responders showed a higher average SUV{sub max}, larger MTV, and greater heterogeneity at all 3 times. Week 4 SUV{sub max} (P=.037), week 4 FDG{sub hetero} (P=.005), pretreatment MTV (P=.008), and pretreatment FDG{sub hetero} (P=.008) were all significantly associated with post-treatment PET response. Conclusions: SUV{sub max} shows a consistent rate of decline during treatment and declines at a faster rate than MTV regresses. Based on this pilot study, pretreatment and week 4 of treatment represent the best time points for prediction of response.« less

  7. Multiparametric [18F]Fluorodeoxyglucose/ [18F]Fluoromisonidazole Positron Emission Tomography/ Magnetic Resonance Imaging of Locally Advanced Cervical Cancer for the Non-Invasive Detection of Tumor Heterogeneity: A Pilot Study

    PubMed Central

    Andrzejewski, Piotr; Baltzer, Pascal; Polanec, Stephan H.; Sturdza, Alina; Georg, Dietmar; Helbich, Thomas H.; Karanikas, Georgios; Grimm, Christoph; Polterauer, Stephan; Poetter, Richard; Wadsak, Wolfgang; Mitterhauser, Markus; Georg, Petra

    2016-01-01

    Objectives To investigate fused multiparametric positron emission tomography/magnetic resonance imaging (MP PET/MRI) at 3T in patients with locally advanced cervical cancer, using high-resolution T2-weighted, contrast-enhanced MRI (CE-MRI), diffusion-weighted imaging (DWI), and the radiotracers [18F]fluorodeoxyglucose ([18F]FDG) and [18F]fluoromisonidazol ([18F]FMISO) for the non-invasive detection of tumor heterogeneity for an improved planning of chemo-radiation therapy (CRT). Materials and Methods Sixteen patients with locally advanced cervix were enrolled in this IRB approved and were examined with fused MP [18F]FDG/ [18F]FMISO PET/MRI and in eleven patients complete data sets were acquired. MP PET/MRI was assessed for tumor volume, enhancement (EH)-kinetics, diffusivity, and [18F]FDG/ [18F]FMISO-avidity. Descriptive statistics and voxel-by-voxel analysis of MRI and PET parameters were performed. Correlations were assessed using multiple correlation analysis. Results All tumors displayed imaging parameters concordant with cervix cancer, i.e. type II/III EH-kinetics, restricted diffusivity (median ADC 0.80x10-3mm2/sec), [18F]FDG- (median SUVmax16.2) and [18F]FMISO-avidity (median SUVmax3.1). In all patients, [18F]FMISO PET identified the hypoxic tumor subvolume, which was independent of tumor volume. A voxel-by-voxel analysis revealed only weak correlations between the MRI and PET parameters (0.05–0.22), indicating that each individual parameter yields independent information and the presence of tumor heterogeneity. Conclusion MP [18F]FDG/ [18F]FMISO PET/MRI in patients with cervical cancer facilitates the acquisition of independent predictive and prognostic imaging parameters. MP [18F]FDG/ [18F]FMISO PET/MRI enables insights into tumor biology on multiple levels and provides information on tumor heterogeneity, which has the potential to improve the planning of CRT. PMID:27167829

  8. Multiparametric [18F]Fluorodeoxyglucose/ [18F]Fluoromisonidazole Positron Emission Tomography/ Magnetic Resonance Imaging of Locally Advanced Cervical Cancer for the Non-Invasive Detection of Tumor Heterogeneity: A Pilot Study.

    PubMed

    Pinker, Katja; Andrzejewski, Piotr; Baltzer, Pascal; Polanec, Stephan H; Sturdza, Alina; Georg, Dietmar; Helbich, Thomas H; Karanikas, Georgios; Grimm, Christoph; Polterauer, Stephan; Poetter, Richard; Wadsak, Wolfgang; Mitterhauser, Markus; Georg, Petra

    2016-01-01

    To investigate fused multiparametric positron emission tomography/magnetic resonance imaging (MP PET/MRI) at 3T in patients with locally advanced cervical cancer, using high-resolution T2-weighted, contrast-enhanced MRI (CE-MRI), diffusion-weighted imaging (DWI), and the radiotracers [18F]fluorodeoxyglucose ([18F]FDG) and [18F]fluoromisonidazol ([18F]FMISO) for the non-invasive detection of tumor heterogeneity for an improved planning of chemo-radiation therapy (CRT). Sixteen patients with locally advanced cervix were enrolled in this IRB approved and were examined with fused MP [18F]FDG/ [18F]FMISO PET/MRI and in eleven patients complete data sets were acquired. MP PET/MRI was assessed for tumor volume, enhancement (EH)-kinetics, diffusivity, and [18F]FDG/ [18F]FMISO-avidity. Descriptive statistics and voxel-by-voxel analysis of MRI and PET parameters were performed. Correlations were assessed using multiple correlation analysis. All tumors displayed imaging parameters concordant with cervix cancer, i.e. type II/III EH-kinetics, restricted diffusivity (median ADC 0.80x10-3mm2/sec), [18F]FDG- (median SUVmax16.2) and [18F]FMISO-avidity (median SUVmax3.1). In all patients, [18F]FMISO PET identified the hypoxic tumor subvolume, which was independent of tumor volume. A voxel-by-voxel analysis revealed only weak correlations between the MRI and PET parameters (0.05-0.22), indicating that each individual parameter yields independent information and the presence of tumor heterogeneity. MP [18F]FDG/ [18F]FMISO PET/MRI in patients with cervical cancer facilitates the acquisition of independent predictive and prognostic imaging parameters. MP [18F]FDG/ [18F]FMISO PET/MRI enables insights into tumor biology on multiple levels and provides information on tumor heterogeneity, which has the potential to improve the planning of CRT.

  9. Pilot Comparison of ⁶⁸Ga-RM2 PET and ⁶⁸Ga-PSMA-11 PET in Patients with Biochemically Recurrent Prostate Cancer.

    PubMed

    Minamimoto, Ryogo; Hancock, Steven; Schneider, Bernadette; Chin, Frederick T; Jamali, Mehran; Loening, Andreas; Vasanawala, Shreyas; Gambhir, Sanjiv Sam; Iagaru, Andrei

    2016-04-01

    Glu-NH-CO-NH-Lys-(Ahx)-[(68)Ga(HBED-CC)] ((68)Ga-PSMA-11) is a PET tracer that can detect prostate cancer relapses and metastases by binding to the extracellular domain of PSMA. (68)Ga-labeled DOTA-4-amino-1-carboxymethyl-piperidine-D-Phe-Gln-Trp-Ala-Val-Gly-His-Sta-Leu-NH2 ((68)Ga-RM2) is a synthetic bombesin receptor antagonist that targets gastrin-releasing peptide receptors. We present pilot data on the biodistribution of these PET tracers in a small cohort of patients with biochemically recurrent prostate cancer. Seven men (mean age ± SD, 74.3 ± 5.9 y) with biochemically recurrent prostate cancer underwent both (68)Ga-PSMA-11 PET/CT and (68)Ga-RM2 PET/MRI scans. SUVmax and SUVmean were recorded for normal tissues and areas of uptake outside the expected physiologic biodistribution. All patients had a rising level of prostate-specific antigen (mean ± SD, 13.5 ± 11.5) and noncontributory results on conventional imaging. (68)Ga-PSMA-11 had the highest physiologic uptake in the salivary glands and small bowel, with hepatobiliary and renal clearance noted, whereas (68)Ga-RM2 had the highest physiologic uptake in the pancreas, with renal clearance noted. Uptake outside the expected physiologic biodistribution did not significantly differ between (68)Ga-PSMA-11 and (68)Ga-RM2; however, (68)Ga-PSMA-11 localized in a lymph node and seminal vesicle in a patient with no abnormal (68)Ga-RM2 uptake. Abdominal periaortic lymph nodes were more easily visualized by(68)Ga-RM2 in two patients because of lack of interference by radioactivity in the small intestine. (68)Ga-PSMA-11 and (68)Ga-RM2 had distinct biodistributions in this small cohort of patients with biochemically recurrent prostate cancer. Additional work is needed to understand the expression of PSMA and gastrin-releasing peptide receptors in different types of prostate cancer. © 2016 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  10. Effects of hyperoxia on 18F-fluoro-misonidazole brain uptake and tissue oxygen tension following middle cerebral artery occlusion in rodents: Pilot studies

    PubMed Central

    Jensen-Kondering, Ulf; Williamson, David J.; Sitnikov, Sergey; Sawiak, Stephen J.; Aigbirhio, Franklin I.; Hong, Young T.

    2017-01-01

    Purpose Mapping brain hypoxia is a major goal for stroke diagnosis, pathophysiology and treatment monitoring. 18F-fluoro-misonidazole (FMISO) positron emission tomography (PET) is the gold standard hypoxia imaging method. Normobaric hyperoxia (NBO) is a promising therapy in acute stroke. In this pilot study, we tested the straightforward hypothesis that NBO would markedly reduce FMISO uptake in ischemic brain in Wistar and spontaneously hypertensive rats (SHRs), two rat strains with distinct vulnerability to brain ischemia, mimicking clinical heterogeneity. Methods Thirteen adult male rats were randomized to distal middle cerebral artery occlusion under either 30% O2 or 100% O2. FMISO was administered intravenously and PET data acquired dynamically for 3hrs, after which magnetic resonance imaging (MRI) and tetrazolium chloride (TTC) staining were carried out to map the ischemic lesion. Both FMISO tissue uptake at 2-3hrs and FMISO kinetic rate constants, determined based on previously published kinetic modelling, were obtained for the hypoxic area. In a separate group (n = 9), tissue oxygen partial pressure (PtO2) was measured in the ischemic tissue during both control and NBO conditions. Results As expected, the FMISO PET, MRI and TTC lesion volumes were much larger in SHRs than Wistar rats in both the control and NBO conditions. NBO did not appear to substantially reduce FMISO lesion size, nor affect the FMISO kinetic rate constants in either strain. Likewise, MRI and TTC lesion volumes were unaffected. The parallel study showed the expected increases in ischemic cortex PtO2 under NBO, although these were small in some SHRs with very low baseline PtO2. Conclusions Despite small samples, the apparent lack of marked effects of NBO on FMISO uptake suggests that in permanent ischemia the cellular mechanisms underlying FMISO trapping in hypoxic cells may be disjointed from PtO2. Better understanding of FMISO trapping processes will be important for future applications of FMISO imaging. PMID:29091934

  11. Effects of hyperoxia on 18F-fluoro-misonidazole brain uptake and tissue oxygen tension following middle cerebral artery occlusion in rodents: Pilot studies.

    PubMed

    Fryer, Tim D; Ejaz, Sohail; Jensen-Kondering, Ulf; Williamson, David J; Sitnikov, Sergey; Sawiak, Stephen J; Aigbirhio, Franklin I; Hong, Young T; Baron, Jean-Claude

    2017-01-01

    Mapping brain hypoxia is a major goal for stroke diagnosis, pathophysiology and treatment monitoring. 18F-fluoro-misonidazole (FMISO) positron emission tomography (PET) is the gold standard hypoxia imaging method. Normobaric hyperoxia (NBO) is a promising therapy in acute stroke. In this pilot study, we tested the straightforward hypothesis that NBO would markedly reduce FMISO uptake in ischemic brain in Wistar and spontaneously hypertensive rats (SHRs), two rat strains with distinct vulnerability to brain ischemia, mimicking clinical heterogeneity. Thirteen adult male rats were randomized to distal middle cerebral artery occlusion under either 30% O2 or 100% O2. FMISO was administered intravenously and PET data acquired dynamically for 3hrs, after which magnetic resonance imaging (MRI) and tetrazolium chloride (TTC) staining were carried out to map the ischemic lesion. Both FMISO tissue uptake at 2-3hrs and FMISO kinetic rate constants, determined based on previously published kinetic modelling, were obtained for the hypoxic area. In a separate group (n = 9), tissue oxygen partial pressure (PtO2) was measured in the ischemic tissue during both control and NBO conditions. As expected, the FMISO PET, MRI and TTC lesion volumes were much larger in SHRs than Wistar rats in both the control and NBO conditions. NBO did not appear to substantially reduce FMISO lesion size, nor affect the FMISO kinetic rate constants in either strain. Likewise, MRI and TTC lesion volumes were unaffected. The parallel study showed the expected increases in ischemic cortex PtO2 under NBO, although these were small in some SHRs with very low baseline PtO2. Despite small samples, the apparent lack of marked effects of NBO on FMISO uptake suggests that in permanent ischemia the cellular mechanisms underlying FMISO trapping in hypoxic cells may be disjointed from PtO2. Better understanding of FMISO trapping processes will be important for future applications of FMISO imaging.

  12. A PET imaging agent for evaluating PARP-1 expression in ovarian cancer.

    PubMed

    Makvandi, Mehran; Pantel, Austin; Schwartz, Lauren; Schubert, Erin; Xu, Kuiying; Hsieh, Chia-Ju; Hou, Catherine; Kim, Hyoung; Weng, Chi-Chang; Winters, Harrison; Doot, Robert; Farwell, Michael D; Pryma, Daniel A; Greenberg, Roger A; Mankoff, David A; Simpkins, Fiona; Mach, Robert H; Lin, Lilie L

    2018-05-01

    Poly(ADP-ribose) polymerase (PARP) inhibitors are effective in a broad population of patients with ovarian cancer; however, resistance caused by low enzyme expression of the drug target PARP-1 remains to be clinically evaluated in this context. We hypothesize that PARP-1 expression is variable in ovarian cancer and can be quantified in primary and metastatic disease using a novel PET imaging agent. We used a translational approach to describe the significance of PET imaging of PARP-1 in ovarian cancer. First, we produced PARP1-KO ovarian cancer cell lines using CRISPR/Cas9 gene editing to test the loss of PARP-1 as a resistance mechanism to all clinically used PARP inhibitors. Next, we performed preclinical microPET imaging studies using ovarian cancer patient-derived xenografts in mouse models. Finally, in a phase I PET imaging clinical trial we explored PET imaging as a regional marker of PARP-1 expression in primary and metastatic disease through correlative tissue histology. We found that deletion of PARP1 causes resistance to all PARP inhibitors in vitro, and microPET imaging provides proof of concept as an approach to quantify PARP-1 in vivo. Clinically, we observed a spectrum of standard uptake values (SUVs) ranging from 2-12 for PARP-1 in tumors. In addition, we found a positive correlation between PET SUVs and fluorescent immunohistochemistry for PARP-1 (r2 = 0.60). This work confirms the translational potential of a PARP-1 PET imaging agent and supports future clinical trials to test PARP-1 expression as a method to stratify patients for PARP inhibitor therapy. Clinicaltrials.gov NCT02637934. Research reported in this publication was supported by the Department of Defense OC160269, a Basser Center team science grant, NIH National Cancer Institute R01CA174904, a Department of Energy training grant DE-SC0012476, Abramson Cancer Center Radiation Oncology pilot grants, the Marsha Rivkin Foundation, Kaleidoscope of Hope Foundation, and Paul Calabresi K12 Career Development Award 5K12CA076931.

  13. Crohn Disease: FDG PET/CT Before and After Initial Dose of Anti-Tumor Necrosis Factor Therapy to Predict Long-term Response.

    PubMed

    Epelboym, Yan; Shyn, Paul B; Chick, Jeffrey Forris Beecham; Hamilton, Matthew J; OʼConnor, Stacy D; Silverman, Stuart G; Kim, Chun K

    2017-11-01

    Clinical assessments of Crohn disease activity are limited in their capacity to assess treatment response to biologic therapy. The purpose of this study was to determine if changes in FDG activity between baseline PET and repeat PET performed prior to the second dose of induction anti-tumor necrosis factor (TNF) therapy correlate with clinical response. In this prospective, institutional review board-approved, Health Insurance Portability and Accountability Act-compliant pilot study of 8 adult patients with active Crohn disease, FDG activity before and 2 weeks after initiation of anti-TNF therapy was assessed using low-dose PET/CT. FDG activity was measured in the most inflamed bowel loop using an SUVratio (SUVmax/liver SUVmean). Changes in SUVratio were compared with a blinded gastroenterologist assessment of clinical response and steroid-free remission, as well as C-reactive protein (CRP), during a 12-month follow-up period. Of 8 patients, 7 showed FDG activity decline at 2 weeks, 5 of whom achieved a clinical response and steroid-free remission at 8, 26, and 52 weeks. The remaining 2 patients with FDG activity decline did not achieve a clinical response or steroid-free remission at these time points, but there were reductions in CRP. The 1 patient without FDG activity decline was a clinical nonresponder, had no reduction in CRP, and did not achieve steroid-free remission. A change in FDG activity at FDG PET/CT performed prior to the second induction dose of anti-TNF therapy has the potential to predict clinical response and steroid-free remission in patients with Crohn disease.

  14. Visual Assessment of Brain Perfusion MRI Scans in Dementia: A Pilot Study.

    PubMed

    Fällmar, David; Lilja, Johan; Velickaite, Vilma; Danfors, Torsten; Lubberink, Mark; Ahlgren, André; van Osch, Matthias J P; Kilander, Lena; Larsson, Elna-Marie

    2016-05-01

    Functional imaging is becoming increasingly important for the detection of neurodegenerative disorders. Perfusion MRI with arterial spin labeling (ASL) has been reported to provide promising diagnostic possibilities but is not yet widely used in routine clinical work. The aim of this study was to compare, in a clinical setting, the visual assessment of subtracted ASL CBF maps with and without additional smoothing, to FDG-PET data. Ten patients with a clinical diagnosis of dementia and 11 age-matched cognitively healthy controls were examined with pseudo-continuous ASL (pCASL) and 18F-Fluorodeoxyglucose positron emission tomography (FDG-PET). Three diagnostic physicians visually assessed the pCASL maps after subtraction only, and after postprocessing using Gaussian smoothing and GLM-based beta estimate functions. The assessment scores were compared to FDG PET values. Furthermore, the ability to discriminate patients from healthy elderly controls was assessed. Smoothing improved the correlation between visually assessed regional ASL perfusion scores and the FDG PET SUV-r values from the corresponding regions. However, subtracted pCASL maps discriminated patients from healthy controls better than smoothed maps. Smoothing increased the number of false-positive patient identifications. Application of beta estimate functions had only a marginal effect. Spatial smoothing of ASL images increased false positive results in the discrimination of hypoperfusion conditions from healthy elderly. It also decreased interreader agreement. However, regional characterization and subjective perception of image quality was improved. Copyright © 2015 by the American Society of Neuroimaging.

  15. Intensity-modulated salvage radiotherapy with simultaneous integrated boost for local recurrence of prostate carcinoma: a pilot study on the place of PET-choline for guiding target volume delineation.

    PubMed

    Wahart, Aurélien; Guy, Jean-Baptiste; Vallard, Alexis; Geissler, Benjamin; Ben Mrad, Majed; Falk, Alexander T; Prevot, Nathalie; de Laroche, Guy; Rancoule, Chloé; Chargari, Cyrus; Magné, Nicolas

    2016-01-01

    The aim of this study was to report the first cases of salvage radiotherapy (RT) using the intensity-modulated radiotherapy (IMRT) with simultaneous integrated boost (SIB) targeted on choline positron emission tomography (PET) uptake in a local recurrent prostate cancer, after a radical prostatectomy. Four patients received salvage irradiation for biochemical relapse that occurred after the initial radical prostatectomy. The relapse occurred from 10 months to 6 years with PSA levels ranging from 2.35 to 4.86 ng ml(-1). For each patient, an (18)F-choline PET-CT showed a focal choline uptake in prostatic fossa, with standardized uptake value calculated on the basis of predicted lean body mass (SUL) max of 3.3-6.8. No involved lymph node or distant metastases were diagnosed. IMRT doses were of 62.7 Gy (1.9 Gy/fraction, 33 fractions), with a SIB of 69.3 Gy (2.1 Gy/fraction, 33 fractions) to a PET-guided target volume. Acute toxicities were limited. We observed no gastrointestinal toxicity ≥grade 2 and only one grade 2 genitourinary toxicity. At 1-month follow-up evaluation, no complication and a decrease in PSA level (6.8-43.8% of the pre-therapeutic level) were reported. After 4 months, a decrease in PSA level was obtained for all the patients, ranging from 30% to 70%. At a median follow-up of 15 months, PSA level was controlled for all the patients, but one of them experienced a distant lymph node recurrence. Salvage irradiation to the prostate bed with SIB guided by PET-CT is feasible, with biological efficacy and no major acute toxicity. IMRT with PET-oriented SIB for salvage treatment of prostate cancer is possible, without major acute toxicity.

  16. Utility of 68Ga-PSMA-11 PET/CT in Imaging of Glioma-A Pilot Study.

    PubMed

    Sasikumar, Arun; Kashyap, Raghava; Joy, Ajith; Charan Patro, Kanhu; Bhattacharya, Parthasarathy; Reddy Pilaka, Venkata Krishna; Oommen, Karuna Elza; Pillai, Maroor Raghavan Ambikalmajan

    2018-06-22

    Imaging of gliomas remains challenging. The aim of the study was to assess the feasibility of using Ga-PSMA-11 PET/CT for imaging gliomas. Fifteen patients with glioma from 2 centers were included in the study. Ten patients were treated cases of glioblastoma with suspected recurrence. Two patients were sent for assessing the nature (primary lesion/metastasis) of space-occupying lesion in the brain; 3 patients were imaged immediately after surgery and before radiotherapy. Target-to-background ratios (TBR) for the brain lesions were calculated using contralateral cerebellar uptake as background. Among the 10 cases with suspected recurrence, scan was positive in 9, subsequent surgery was done, and histopathology proved it to be true recurrence. In the scan-negative case on follow-up, no evidence of disease could be made clinically or radiologically. Among the other cases the presence or absence of disease could be unequivocally identified on the Ga-PSMA-11 brain scan and correlated with the histopathology or other imaging. Apart from the visual assessment quantitative assessment of the lesions with TBR also showed a significantly high TBR value for those with true disease compared with those with no disease. In the evaluation of gliomas, Ga-PSMA-11 PET/CT brain imaging is a potentially useful imaging tool. The use of Ga-PSMA-11 brain PET/CT in evaluation of recurrent glioma seems promising. Absence of physiological uptake of Ga-PSMA-11 in the normal brain parenchyma results in high TBR values and consequently better visualization of glioma lesions.

  17. A pilot study into the effects of music therapy on different areas of the brain of individuals with unresponsive wakefulness syndrome

    PubMed Central

    Steinhoff, Nikolaus; Heine, Astrid M.; Vogl, Julia; Weiss, Konrad; Aschraf, Asita; Hajek, Paul; Schnider, Peter; Tucek, Gerhard

    2015-01-01

    The global cerebral network allows music “ to do to us what it does.” While the same music can cause different emotions, the basic emotion of happy and sad songs can, nevertheless, be understood by most people. Consequently, the individual experience of music and its common effect on the human brain is a challenging subject for research. Various activities such as hearing, processing, and performing music provide us with different pictures of cerebral centers in PET. In comparison to these simple acts of experiencing music, the interaction and the therapeutic relationship between the patient and the therapist in Music Therapy (MT) provide us with an additional element in need of investigation. In the course of a pilot study, these problems were approached and reduced to the simple observation of pattern alteration in the brains of four individuals with Unresponsive Wakefulness Syndrome (UWS) during MT. Each patient had three PET investigations: (i) during a resting state, (ii) during the first exposure to MT, and (iii) during the last exposure to MT. Two patients in the MT group received MT for 5 weeks between the 2nd and the 3rd PET (three times a week), while two other patients in the control group had no MT in between. Tracer uptake was measured in the frontal, hippocampal, and cerebellar region of the brain. With certain differences in these three observed brain areas, the tracer uptake in the MT group was higher (34%) than in the control group after 5 weeks. The preliminary results suggest that MT activates the three brain regions described above. In this article, we present our approach to the neuroscience of MT and discuss the impact of our hypothesis on music therapy practice, neurological rehabilitation of individuals in UWS and additional neuroscientific research. PMID:26347603

  18. A pilot study into the effects of music therapy on different areas of the brain of individuals with unresponsive wakefulness syndrome.

    PubMed

    Steinhoff, Nikolaus; Heine, Astrid M; Vogl, Julia; Weiss, Konrad; Aschraf, Asita; Hajek, Paul; Schnider, Peter; Tucek, Gerhard

    2015-01-01

    The global cerebral network allows music " to do to us what it does." While the same music can cause different emotions, the basic emotion of happy and sad songs can, nevertheless, be understood by most people. Consequently, the individual experience of music and its common effect on the human brain is a challenging subject for research. Various activities such as hearing, processing, and performing music provide us with different pictures of cerebral centers in PET. In comparison to these simple acts of experiencing music, the interaction and the therapeutic relationship between the patient and the therapist in Music Therapy (MT) provide us with an additional element in need of investigation. In the course of a pilot study, these problems were approached and reduced to the simple observation of pattern alteration in the brains of four individuals with Unresponsive Wakefulness Syndrome (UWS) during MT. Each patient had three PET investigations: (i) during a resting state, (ii) during the first exposure to MT, and (iii) during the last exposure to MT. Two patients in the MT group received MT for 5 weeks between the 2nd and the 3rd PET (three times a week), while two other patients in the control group had no MT in between. Tracer uptake was measured in the frontal, hippocampal, and cerebellar region of the brain. With certain differences in these three observed brain areas, the tracer uptake in the MT group was higher (34%) than in the control group after 5 weeks. The preliminary results suggest that MT activates the three brain regions described above. In this article, we present our approach to the neuroscience of MT and discuss the impact of our hypothesis on music therapy practice, neurological rehabilitation of individuals in UWS and additional neuroscientific research.

  19. Pilot Study on Long Term Effects of HZE Exposure on the Canine Brain

    NASA Astrophysics Data System (ADS)

    Budinger, T.; Brennan, K.; Pearlstein, R.

    A ground-based pilot experiment was initiated in December 1992 to evaluate the long term effects on health and aging after HZE cosmic radiation of the canine brain. Six adult male beagle dogs (1 yr) from the UC Davis breeding colony at the Laboratory for Energy Related Health Research were researched in this study. Iron nuclei at 600 MeV/amu (180 keV/mm) were used to irradiate the whole brain. The fluence of 3 x 106 iron nuclei/ cm2 mimics the HZE exposure (all > He) for a 2- year mission to Mars. The HZE irradiation was a fully stripped iron particle beam at the LBNL BEVALAC. Using a Raster Scanner we were able to spread the beam to deliver a uniform dose over the brain. The total dose to the brain was 200 cGy. Four dogs were whole brain irradiated with iron and two dogs served as litter-mate controls. The control dogs received a similar amount of background neutron irradiation as the irradiated dogs. One of the control dogs died suddenly 3/98 of intestinal cancer unrelated to the brain irradiation. That brain was not harvested before autolysis had prevented analysis. Periodic PET metabolism and yearly MRI studies have been done on these dog's brain since irradiation. All dogs had yearly physical, neurological and blood chemistry work-ups. PET imaging was performed with the Donner 600-crystal high-resolution PET (2.6 mm resolution) and with the commercial PET, CTI/Siemens ECAT 951 PET Scanner (5 mm resolution). NMR imaging is performed with the 1 5T GE Signa at UCSF using T spoiled gradient imaging.1 sequences for T1 contrast at 1 mm resolution as well as a T2 weighted spin echo imaging sequence at 1 mm resolution. A major goal of this work is to present an accurate method for measuring surface areas and volumes of the irradiated vs the non-irradiated canine brain using MRI data which are isotropic in resolution at the 1 mm level. This allows us to monitor the changes in brain size with aging and radiation exposure. Nine years post irradiation, these dog brains (+ 3 additional age-matched controls) were in-situ perfused with 4% paraformaldehyde/01.M phosphate buffer. The brain was removed and fixed in the same fixative for 2 weeks. Brain sections were embedded in parafin and cut at 6 or 12 μm thickness. Histology included H&E, Luxol fast blue and Silver staining. Immunochemistry included Amyloidprecursor protein. There was no marked increase in amyloid plaque formation in the irradiated dogs. Imaging and histology results will be presented at the COSPAR conference.

  20. [18F]-Fluoromisonidazole Positron Emission Tomography/Computed Tomography Visualization of Tumor Hypoxia in Patients With Chordoma of the Mobile and Sacrococcygeal Spine

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cheney, Matthew D., E-mail: mcheney@lroc.harvard.edu; Chen, Yen-Lin; Lim, Ruth

    2014-12-01

    Purpose: To investigate [18F]-fluoromisonidazole positron emission tomography/computed tomography (FMISO-PET/CT) detection of targetable hypoxic subvolumes (HSVs) in chordoma of the mobile or sacrococcygeal spine. Methods and Materials: A prospective, pilot study of 20 patients with primary or locally recurrent chordoma of the mobile or sacrococcygeal spine treated with proton or combined proton/photon radiation therapy (RT) with or without surgery was completed. The FMISO-PET/CT was performed before RT and after 19.8-34.2 GyRBE (relative biologic effectiveness). Gross tumor volumes were delineated and HSVs defined including voxels with standardized uptake values ≥1.4 times the muscle mean. Clinical characteristics and treatments received were compared betweenmore » patients with and without HSVs. Results: The FMISO-PET/CT detected HSVs in 12 of 20 patients (60%). Baseline and interval HSV spatial concordance varied (0%-94%). Eight HSVs were sufficiently large (≥5 cm{sup 3}) to potentially allow an intensity modulated proton therapy boost. Patients with HSVs had significantly larger gross tumor volumes (median 410.0 cm{sup 3} vs 63.4 cm{sup 3}; P=.02) and were significantly more likely to have stage T2 tumors (5 of 12 vs 0 of 8; P=.04). After a median follow-up of 1.8 years (range, 0.2-4.4 years), a local recurrence has yet to be observed. Three patients developed metastatic disease, 2 with HSVs. Conclusions: Detection of targetable HSVs by FMISO-PET/CT within patients undergoing RT with or without surgery for treatment of chordoma of the mobile and sacrococcygeal spine is feasible. The study's inability to attribute interval HSV changes to treatment, rapidly changing hypoxic physiology, or imaging inconsistencies is a limitation. Further study of double-baseline FMISO-PET/CT and hypoxia-directed RT dose escalation, particularly in patients at high risk for local recurrence, is warranted.« less

  1. Astronaut Alan L. Bean - Family - Houston, TX

    NASA Image and Video Library

    1973-07-05

    S73-31104 (17 July 1973) --- The wife and children of astronaut Alan L. Bean are photographed at their home near the Johnson Space Center (JSC), where their husband and father is preparing for NASA?s second manned Skylab mission. Bean is commander of the Skylab 3 Earth-orbital mission and will be joined by scientist-astronaut Owen K. Garriott, science pilot, and astronaut Jack R. Lousma, pilot for the schedule two-month mission. With Mrs. Sue Bean are the couple?s children Clay, 17, and Amy Sue, 10; and the family?s pet dog. Photo credit: NASA

  2. PET/CT imaging of the diapeutic alkylphosphocholine analog 124I-CLR1404 in high and low-grade brain tumors

    PubMed Central

    Hall, Lance T; Titz, Benjamin; Robins, H Ian; Bednarz, Bryan P; Perlman, Scott B; Weichert, Jamey P; Kuo, John S

    2017-01-01

    CLR1404 is a cancer-selective alkyl phosphocholine (APC) analog that can be radiolabeled with 124I for PET imaging, 131I for targeted radiotherapy and/or SPECT imaging, or 125I for targeted radiotherapy. Studies have demonstrated avid CLR1404 uptake and prolonged retention in a broad spectrum of preclinical tumor models. The purpose of this pilot trial was to demonstrate avidity of 124I-CLR1404 in human brain tumors and develop a framework to evaluate this uptake for use in larger studies. 12 patients (8 men and 4 women; mean age of 43.9 ± 15.1 y; range 23-66 y) with 13 tumors were enrolled. Eleven patients had suspected tumor recurrence and 1 patient had a new diagnosis of high grade tumor. Patients were injected with 185 MBq ± 10% of 124I-CLR1404 followed by PET/CT imaging at 6-, 24-, and 48-hour. 124I-CLR1404 PET uptake was assessed qualitatively and compared with MRI. After PET image segmentation SUV values and tumor to background ratios were calculated. There was no significant uptake of 124I-CLR1404 in normal brain. In tumors, uptake tended to increase to 48 hours. Positive uptake was detected in 9 of 13 lesions: 5/5 high grade tumors, 1/2 low grade tumors, 1/1 meningioma, and 2/4 patients with treatment related changes. 124I-CLR1404 uptake was not detected in 1/2 low grade tumors, 2/4 lesions from treatment related changes, and 1/1 indeterminate lesion. For 6 malignant tumors, the average tumor to background ratios (TBR) were 9.32 ± 4.33 (range 3.46 to 15.42) at 24 hours and 10.04 ± 3.15 (range 5.17 to 13.17) at 48 hours. For 2 lesions from treatment related change, the average TBR were 5.05 ± 0.4 (range 4.76 to 5.33) at 24 hours and 4.88 ± 1.19 (range 4.04 to 5.72) at 48 hours. PET uptake had areas of both concordance and discordance compared with MRI. 124I-CLR1404 PET demonstrated avid tumor uptake in a variety of brain tumors with high tumor-to-background ratios. There were regions of concordance and discordance compared with MRI, which has potential clinical relevance. Expansion of these studies is required to determine the clinical significance of the 124I-CLR1404 PET findings. PMID:28913154

  3. Automatic Detection of Lung and Liver Lesions in 3-D Positron Emission Tomography Images: A Pilot Study

    NASA Astrophysics Data System (ADS)

    Lartizien, Carole; Marache-Francisco, Simon; Prost, Rémy

    2012-02-01

    Positron emission tomography (PET) using fluorine-18 deoxyglucose (18F-FDG) has become an increasingly recommended tool in clinical whole-body oncology imaging for the detection, diagnosis, and follow-up of many cancers. One way to improve the diagnostic utility of PET oncology imaging is to assist physicians facing difficult cases of residual or low-contrast lesions. This study aimed at evaluating different schemes of computer-aided detection (CADe) systems for the guided detection and localization of small and low-contrast lesions in PET. These systems are based on two supervised classifiers, linear discriminant analysis (LDA) and the nonlinear support vector machine (SVM). The image feature sets that serve as input data consisted of the coefficients of an undecimated wavelet transform. An optimization study was conducted to select the best combination of parameters for both the SVM and the LDA. Different false-positive reduction (FPR) methods were evaluated to reduce the number of false-positive detections per image (FPI). This includes the removal of small detected clusters and the combination of the LDA and SVM detection maps. The different CAD schemes were trained and evaluated based on a simulated whole-body PET image database containing 250 abnormal cases with 1230 lesions and 250 normal cases with no lesion. The detection performance was measured on a separate series of 25 testing images with 131 lesions. The combination of the LDA and SVM score maps was shown to produce very encouraging detection performance for both the lung lesions, with 91% sensitivity and 18 FPIs, and the liver lesions, with 94% sensitivity and 10 FPIs. Comparison with human performance indicated that the different CAD schemes significantly outperformed human detection sensitivities, especially regarding the low-contrast lesions.

  4. Utility of early dynamic and delayed post-diuretic 18F-FDG PET/CT SUVmax in predicting tumour grade and T-stage of urinary bladder carcinoma: results from a prospective single centre study.

    PubMed

    Sharma, Abhishek; Mete, Uttam K; Sood, Ashwani; Kakkar, Nandita; Gorla, Arun K R; Mittal, Bhagwant R

    2017-04-01

    Accurate pre-treatment grading and staging of bladder cancer are vital for better therapeutic decision and prognosis. The aim of the present study was to evaluate the correlation between maximum standardized uptake value (SUV max ) calculated during early dynamic and post-diuretic fluorine-18 fludeoxyglucose ( 18 F-FDG) positron emission tomography (PET)/CT studies with grade and pT-stage of bladder cancer. 39 patients with suspected/proven bladder carcinoma underwent 10-min early dynamic pelvic imaging and delayed post-diuretic whole-body FDG PET/CT imaging. SUV max of the lesions derived from both studies was compared with grade and pT-stage. Relationship of SUV max with grade and pT-stage was analyzed using independent sample t-test and analysis of variance. SUV max of the early dynamic imaging showing tumour perfusion was independent from the SUV max of delayed imaging. High-grade tumours showed higher SUV max than low-grade tumours in the early dynamic imaging (5.4 ± 1.4 vs 4.7 ± 1.6; p-value 0.144) with statistically significant higher value in Stage pT1 tumours (6.8 ± 0.8 vs 5.5 ± 1.2; p-value 0.04). Non-invasive pTa tumours had significantly less SUV max than higher stage tumours during early dynamic imaging [F(4,29) = 6.860, p 0.001]. Early dynamic imaging may have a role in predicting the grade and aggressiveness of the bladder tumours and thus can help in treatment planning and prognostication. Advances in knowledge: Dynamic PET/CT is a limitedly explored imaging technique. This prospective pilot study demonstrates the utility of this modality as a potential adjunct to standard FDG PET/CT imaging in predicting the grade and aggressiveness of the bladder tumours and thus can impact the patient management.

  5. The renal blood flow reserve in healthy humans and patients with atherosclerotic renovascular disease measured by positron emission tomography using [15O]H2O.

    PubMed

    Päivärinta, Johanna; Koivuviita, Niina; Oikonen, Vesa; Iida, Hidehiro; Liukko, Kaisa; Manner, Ilkka; Löyttyniemi, Eliisa; Nuutila, Pirjo; Metsärinne, Kaj

    2018-06-11

    Microvascular function plays an important role in ARVD (atherosclerotic renovascular disease). RFR (renal flow reserve), the capacity of renal vasculature to dilate, is known to reflect renal microvascular function. In this pilot study, we assessed PET (positron emission tomography)-based RFR values of healthy persons and renal artery stenosis patients. Seventeen patients with ARVD and eight healthy subjects were included in the study. Intravenous enalapril 1 mg was used as a vasodilatant, and the maximum response (blood pressure and RFR) to it was measured at 40 min. Renal perfusion was measured by means of oxygen-15-labeled water PET. RFR was calculated as a difference of stress flow and basal flow and was expressed as percent [(stress blood flow - basal blood flow)/basal blood flow] × 100%. RFR of the healthy was 22%. RFR of the stenosed kidneys of bilateral stenosis patients (27%) was higher than that of the stenosed kidneys of unilateral stenosis patients (15%). RFR of the contralateral kidneys of unilateral stenosis patients was 21%. There was no difference of statistical significance between RFR values of ARVD subgroups or between ARVD subgroups and the healthy. In the stenosed kidneys of unilateral ARVD patients, stenosis grade of the renal artery correlated negatively with basal (p = 0.04) and stress flow (p = 0.02). Dispersion of RFR values was high. This study is the first to report [ 15 O]H 2 O PET-based RFR values of healthy subjects and ARVD patients in humans. The difference between RFR values of ARVD patients and the healthy did not reach statistical significance perhaps because of high dispersion of RFR values. [ 15 O]H 2 O PET is a valuable non-invasive and quantitative method to evaluate renal blood flow though high dispersion makes imaging challenging. Larger studies are needed to get more information about [ 15 O]H 2 O PET method in evaluation of renal blood flow.

  6. Physical properties of ZrC/Al2O3 imbedded heat storage woven fabrics

    NASA Astrophysics Data System (ADS)

    Kim, S. J.; Song, M. K.; Seo, K. O.; Kim, H. A.

    2017-10-01

    This study investigated different physical properties of ZrC/Al2O3 imbedded heat storage woven fabrics. ZrC and Al2O3 imbedded heat storage PET filaments were spun on the pilot spinning equipment, respectively. Various physical properties of ceramic imbedded fabrics made of ZrC and Al2O3 imbedded filaments were measured and compared with those of the regular PET woven fabric. The surface temperatures of the ZrC and Al2O3 imbedded fabrics were higher than that of the regular fabric. Water absorption rate of ceramic imbedded fabrics was better than that of the regular fabric and drying property was inferior to that of regular fabric. Breathability by water vapour resistance(Ref) of ZrC imbedded fabric was superior to that of regular fabric. Heat keepability rates of the ceramic imbedded fabrics were higher than that of the regular fabrics, which revealed a good heat storage property of the ZrC/Al2O3 imbedded fabrics.

  7. Value of 18F-3,4-dihydroxyphenylalanine PET/MR image fusion in pediatric supratentorial infiltrative astrocytomas: a prospective pilot study.

    PubMed

    Morana, Giovanni; Piccardo, Arnoldo; Milanaccio, Claudia; Puntoni, Matteo; Nozza, Paolo; Cama, Armando; Zefiro, Daniele; Cabria, Massimo; Rossi, Andrea; Garrè, Maria Luisa

    2014-05-01

    Infiltrative astrocytomas (IAs) represent a group of astrocytic gliomas ranging from low-grade to highly malignant, characterized by diffuse invasion of the brain parenchyma. When compared with their adult counterpart, pediatric IAs may be considered biologically distinct entities; nevertheless, similarly to those in adults they represent a complex oncologic challenge. The aim of this study was to investigate the diagnostic role, clinical contribution, and prognostic value of fused (18)F-3,4-dihydroxyphenylalanine ((18)F-DOPA) PET/MR images in pediatric supratentorial IAs. Pediatric patients with supratentorial IAs involving at least 2 cerebral lobes, either newly diagnosed or with suspected disease progression, prospectively underwent (18)F-DOPA PET and conventional MR imaging, performed within 10 d of each other. (18)F-DOPA PET data were interpreted qualitatively and semiquantitatively, fusing images with MR images. PET scans were classified as positive if tumors identified on MR imaging exhibited tracer uptake above the level of the corresponding contralateral normal brain. Maximum standardized uptake values, tumor-to-normal contralateral tissue ratios, and tumor-to-normal striatum ratios were calculated for all tumors. Correlations between the degree and extent of (18)F-DOPA uptake, MR imaging tumor characteristics, and histologic results were investigated. The contribution of (18)F-DOPA PET/MR image fusion was considered relevant if it enabled one to select the most appropriate biopsy site, discriminate between disease progression and treatment-related changes, or influence treatment strategy. The patient's outcome was finally correlated with (18)F-DOPA uptake. Thirteen patients (8 boys and 5 girls) were included (5 diffuse astrocytomas, 2 anaplastic astrocytomas, 5 gliomatosis cerebri, and 1 glioblastoma multiforme). The (18)F-DOPA uptake pattern was heterogeneous in all positive scans (9/13), revealing metabolic heterogeneities within each tumor. Significant differences in terms of (18)F-DOPA uptake were found between low- and high-grade lesions (P < 0.05). The diagnostic and therapeutic contribution of (18)F-DOPA PET/MR image fusion was relevant in 9 of 13 patients (69%). (18)F-DOPA uptake correlated significantly with progression-free survival (P = 0.004). Our results indicate that (18)F-DOPA PET/MR image fusion may be a reliable imaging biomarker of pediatric IAs. Information gathered by this combined imaging approach can be readily transferred to the everyday practice and may help clinicians to better stratify patients with IAs, especially diffuse astrocytomas and gliomatosis cerebri, for diagnostic, therapeutic, and prognostic purposes.

  8. Early-Phase 11C-PiB PET in Amyloid Angiopathy-Related Symptomatic Cerebral Hemorrhage: Potential Diagnostic Value?

    PubMed Central

    Aigbirhio, Franklin I.; Fryer, Tim D.; Menon, David K.; Warburton, Elizabeth A.; Baron, Jean-Claude

    2015-01-01

    Although late-phase (>35min post-administration) 11C-PiB-PET has good sensitivity in cerebral amyloid angiopathy (CAA), its specificity is poor due to frequently high uptake in healthy aged subjects. By detecting perfusion-like abnormalities, early-phase 11C-PiB-PET might add diagnostic value. Early-frame (1–6min) 11C-PiB-PET was obtained in 11 non-demented patients with probable CAA-related symptomatic lobar intracerebral haemorrhage (70±7yrs), 9 age-matched healthy controls (HCs) and 10 HCs <55yrs. There was a significant decrease in early-phase atrophy-corrected whole-cortex SUV relative to cerebellar vermis (SUVR) in the CAA vs age-matched HC group. None of the age-matched controls fell below the lower 95% confidence limit derived from the young HCs, while 6/11 CAA patients did (sensitivity = 55%, specificity = 100%). Combining both early- and late-phase 11C-PiB data did not change the sensitivity and specificity of late-phase PiB, but combined early- and late-phase positivity entails a very high suspicion of underlying Aβ-related clinical disorder, i.e., CAA or Alzheimer disease (AD). In order to clarify this ambiguity, we then show that the occipital/posterior cingulate ratio is markedly lower in CAA than in AD (N = 7). These pilot data suggest that early-phase 11C-PiB-PET may not only add to late-phase PiB-PET with respect to the unclear situation of late-phase positivity, but also help differentiate CAA from AD. PMID:26439113

  9. WE-G-BRD-06: Variation in Dynamic Positron Emission Tomography Imaging of Tumor Hypoxia in Early Stage Non-Small Cell Lung Cancer Patients Undergoing Stereotactic Body Radiotherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kelada, O; Department of Medical Physics in Radiation Oncology, German Cancer Research Center, Heidelberg; Decker, R

    2014-06-15

    Purpose: Tumor hypoxia is correlated with treatment failure. To date, there are no published studies investigating hypoxia in non-small cell lung cancer (NSCLC) patients undergoing SBRT. We aim to use 18F-fluoromisonidazole (18F-FMISO) positron emission tomography (PET) imaging to non-invasively quantify the tumor hypoxic volume (HV), to elucidate potential roles of reoxygenation and tumor vascular response at high doses, and to identify an optimal prognostic imaging time-point. Methods: SBRT-eligible patients with NSCLC tumors >1cm were prospectively enrolled in an IRB-approved study. Computed Tomography and dynamic PET images (0–120min, 150–180min, and 210–240min post-injection) were acquired using a Siemens BiographmCT PET/CT scanner. 18F-FMISOmore » PET was performed on a single patient at 3 different time points around a single SBRT delivery of 18 Gy and HVs were compared using a tumor-to-blood ratio (TBR)>1.2 and rate of influx (Ki)>0.0015 (Patlak). Results: Results from our first patient showed substantial temporal changes in HV following SBRT. Using a TBR threshold >1.2 and summed images 210–240min, the HVs were 19%, 31% and 13% of total tumor volume on day 0, 2 (48 hours post-SBRT), and 4 (96 hours post-SBRT). The absolute volume of hypoxia increased by nearly a factor of 2 after 18 Gy and then decreased almost to baseline 96 hours later. Selected imaging timepoints resulted in temporal changes in HV quantification obtained with TBR. Ki, calculated using 4-hour dynamic data, evaluated HVs as 22%, 75% and 21%, respectively. Conclusions: ith the results of only one patient, this novel pilot study highlights the potential benefit of 18F-FMISO PET imaging as results indicate substantial temporal changes in tumor HV post-SBRT. Analysis suggests that TBR is not a robust parameter for accurate HV quantification and heavily influenced by imaging timepoint selection. Kinetic modeling parameters are more sensitive and may aid in future treatment individualization based on patient-specific biological information.« less

  10. A PET Design Based on SiPM and Monolithic LYSO Crystals: Performance Evaluation

    NASA Astrophysics Data System (ADS)

    González, Antonio J.; Aguilar, Albert; Conde, Pablo; Hernández, Liczandro; Moliner, Laura; Vidal, Luis F.; Sánchez, Filomeno; Sánchez, Sebastián; Correcher, Carlos; Molinos, César; Barberá, Julio; Lankes, Konrad; Junge, Sven; Bruckbauer, Thomas; Bruyndonckx, Peter; Benlloch, Jose M.

    2016-10-01

    A new small animal PET based on SiPM and monolithic LYSO crystals has been developed. Eight detector modules form the PET ring, each mounting an array of 12 × 12 SiPMs coupled to a readout providing the summed signals of the pixels on each of the 12 rows and 12 columns of the SiPM array. This design makes it possible to accurately determine the centroid of the scintillation light distribution with about 1.6 mm full width at half maximum (FWHM) resolution without correction for the 1 mm source size, and the photon depth of interaction (DOI) with nearly 2 mm FWHM. This single ring PET system has a homogeneous spatial resolution across the entire 80 mm transaxial field of view (FOV) of about 1 mm FWHM. The noise equivalent count rate (NECR) peak is estimated to occur at around 39.2 MBq with a rate of approximately 82.7 kcps for the mouse-like phantom and 22 kcps at 48.1 MBq for the rat-like phantom. Following the NEMA protocol, the peak absolute sensitivity in the center of the FOV is 2.8% for a 30% peak energy window. A pilot test injecting NaF to a mouse of 20 grams is also presented. Finally, the PET ring has been tested in front of a high field 15.2 T Magnetic Resonance (MR). No significant variation on energy and spatial resolution across the FOV has been observed due to the presence of the magnetic field.

  11. Providing an information prescription in veterinary medical clinics: a pilot study.

    PubMed

    Kogan, Lori R; Schoenfeld-Tacher, Regina; Gould, Lauren; Viera, Ann R; Hellyer, Peter W

    2014-01-01

    The study assesses the impact on client behavior and attitudes toward receiving an information prescription as part of a veterinary office visit. A random sample of veterinary clinics from a Western US metropolitan area was asked to distribute an information prescription in addition to their customary veterinary services. All clients, regardless of the reason for their visit, were presented with an information prescription: a handout that included the uniform resource locator (URL) to a general veterinary medicine website and several tips to help their clients make more informed choices about where to seek pet health information online. Nearly 40% of clients who reported that they remembered receiving the information prescription accessed the website at least once. Of the clients who reported accessing the suggested website, 86.3% reported finding it "very helpful" or "somewhat helpful." Nearly all the clients (87.9%) reported feeling the information on the site helped them make better decisions for their pets. Most clients reported that it helped them talk to their veterinarians (89.9%) and added to the information they received during their veterinary visits (83.5%). Clients appreciate and utilize veterinary prescriptions, suggesting that this is a tool that both veterinarians and librarians can use to improve animal health and client relations. The value placed on reliable Internet information by veterinary clients suggests several opportunities for librarians to become more proactive in partnering with veterinarians to facilitate the education of pet owners.

  12. Providing an information prescription in veterinary medical clinics: a pilot study

    PubMed Central

    Kogan, Lori R.; Schoenfeld-Tacher, Regina; Gould, Lauren; Viera, Ann R.; Hellyer, Peter W.

    2014-01-01

    Objective: The study assesses the impact on client behavior and attitudes toward receiving an information prescription as part of a veterinary office visit. Methods: A random sample of veterinary clinics from a Western US metropolitan area was asked to distribute an information prescription in addition to their customary veterinary services. All clients, regardless of the reason for their visit, were presented with an information prescription: a handout that included the uniform resource locator (URL) to a general veterinary medicine website and several tips to help their clients make more informed choices about where to seek pet health information online. Results: Nearly 40% of clients who reported that they remembered receiving the information prescription accessed the website at least once. Of the clients who reported accessing the suggested website, 86.3% reported finding it “very helpful” or “somewhat helpful.” Nearly all the clients (87.9%) reported feeling the information on the site helped them make better decisions for their pets. Most clients reported that it helped them talk to their veterinarians (89.9%) and added to the information they received during their veterinary visits (83.5%). Conclusions: Clients appreciate and utilize veterinary prescriptions, suggesting that this is a tool that both veterinarians and librarians can use to improve animal health and client relations. Implications: The value placed on reliable Internet information by veterinary clients suggests several opportunities for librarians to become more proactive in partnering with veterinarians to facilitate the education of pet owners. PMID:24415918

  13. What Factors Are Associated with Positive Effects of Dog Ownership in Families with Children with Autism Spectrum Disorder? The Development of the Lincoln Autism Pet Dog Impact Scale

    PubMed Central

    Hall, Sophie Susannah; Wright, Hannah F.; Mills, Daniel Simon

    2016-01-01

    Scientific literature exploring the value of assistance dogs to children with autism spectrum disorder (ASD) is rapidly emerging. However, there is comparably less literature reporting the effects of pet (as opposed to assistance) dogs to these children. In particular, there are no known validated scales which assess how children may alter their behaviours in the presence of the dog, to evaluate the efficacy of pet dogs to these families. Additionally, given the highly individualised nature of ASD it is likely that some children and families gain more benefits from dog ownership than others, yet no research has reported the effect of individual differences. This pilot study reports the development of a 28-item scale based on the perceived impact of a pet dog on a child with autism by parents (Lincoln Autism Pet Dog Impact Scale—LAPDIS). The scale is comprised of three mathematically derived factors: Adaptability, Social Skills and Conflict Management. We assessed how individual differences (aspects) may be associated with scores on these three factors. Family Aspects and Dog Aspects were not significantly associated with ratings on the three factors, but Child Aspects (including: contact with horses, child age, disability level and language abilities) were related to impact of the dog on all factors. Training Aspects were related to scores on Social Skills (formal training with children with ASD and dogs and attendance at PAWS workshops run by Dogs for Good). These results suggest that individual differences associated with the child and the training approach may be important considerations for a positive impact from dog ownership on families with children with ASD. Differences in family features and the dog may not be so important, but may be worthy of further investigations given the early stage of development in this field. PMID:26894820

  14. What Factors Are Associated with Positive Effects of Dog Ownership in Families with Children with Autism Spectrum Disorder? The Development of the Lincoln Autism Pet Dog Impact Scale.

    PubMed

    Hall, Sophie Susannah; Wright, Hannah F; Mills, Daniel Simon

    2016-01-01

    Scientific literature exploring the value of assistance dogs to children with autism spectrum disorder (ASD) is rapidly emerging. However, there is comparably less literature reporting the effects of pet (as opposed to assistance) dogs to these children. In particular, there are no known validated scales which assess how children may alter their behaviours in the presence of the dog, to evaluate the efficacy of pet dogs to these families. Additionally, given the highly individualised nature of ASD it is likely that some children and families gain more benefits from dog ownership than others, yet no research has reported the effect of individual differences. This pilot study reports the development of a 28-item scale based on the perceived impact of a pet dog on a child with autism by parents (Lincoln Autism Pet Dog Impact Scale--LAPDIS). The scale is comprised of three mathematically derived factors: Adaptability, Social Skills and Conflict Management. We assessed how individual differences (aspects) may be associated with scores on these three factors. Family Aspects and Dog Aspects were not significantly associated with ratings on the three factors, but Child Aspects (including: contact with horses, child age, disability level and language abilities) were related to impact of the dog on all factors. Training Aspects were related to scores on Social Skills (formal training with children with ASD and dogs and attendance at PAWS workshops run by Dogs for Good). These results suggest that individual differences associated with the child and the training approach may be important considerations for a positive impact from dog ownership on families with children with ASD. Differences in family features and the dog may not be so important, but may be worthy of further investigations given the early stage of development in this field.

  15. Characterization of brain mGluR5 binding in a pilot study of late-life major depressive disorder using positron emission tomography and [11C]ABP688

    PubMed Central

    DeLorenzo, C; Sovago, J; Gardus, J; Xu, J; Yang, J; Behrje, R; Kumar, J S D; Devanand, D P; Pelton, G H; Mathis, C A; Mason, N S; Gomez-Mancilla, B; Aizenstein, H; Mann, J J; Parsey, R V

    2015-01-01

    The metabotropic glutamate receptor subtype 5 (mGluR5) has been implicated in the pathophysiology of mood and anxiety disorders and is a potential treatment target in major depressive disorder (MDD). This study compared brain mGluR5 binding in elderly patients suffering from MDD with that in elderly healthy volunteers using positron emission tomography (PET) and [11C]ABP688. Twenty elderly (mean age: 63.0±6.3) subjects with MDD and twenty-two healthy volunteers in the same age range (mean age: 66.4±7.3) were examined with PET after a single bolus injection of [11C]ABP688, with many receiving arterial sampling. PET images were analyzed on a region of interest and a voxel level to compare mGluR5 binding in the brain between the two groups. Differences in [11C]ABP688 binding between patients with early- and late-onset depression were also assessed. In contrast to a previously published report in a younger cohort, no significant difference in [11C]ABP688 binding was observed between elderly subjects with MDD and healthy volunteers. [11C]ABP688 binding was also similar between subgroups with early- or late-onset depression. We believe this is the first study to examine mGluR5 expression in depression in the elderly. Although future work is required, results suggest potential differences in the pathophysiology of elderly depression versus depression earlier in life. PMID:26645628

  16. Pilot-scale electron cyclotron resonance-metal organic chemical vapor deposition system for the preparation of large-area fluorine-doped SnO{sub 2} thin films

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jeon, Bup Ju; Hudaya, Chairul; Center for Energy Convergence, Green City Research Institute, Korea Institute of Science and Technology, Hwarangno 14 gil 5, Seoul 136-791

    2016-05-15

    The authors report the surface morphology, optical, electrical, thermal and humidity impacts, and electromagnetic interference properties of fluorine-doped tin oxide (SnO{sub 2}:F or “FTO”) thin films on a flexible polyethylene terephthalate (PET) substrate fabricated by a pilot-scale electron cyclotron resonance–metal organic chemical vapor deposition (PS ECR-MOCVD). The characteristics of large area FTO thin films were compared with a commercially available transparent conductive electrode made of tin-doped indium oxide (ITO), prepared with an identical film and PET thickness of 125 nm and 188 μm, respectively. The results revealed that the as-prepared FTO thin films exhibited comparable performances with the incumbent ITO films, includingmore » a high optical transmittance of 97% (substrate-subtracted), low electrical resistivity of about 5 × 10{sup −3} Ω cm, improved electrical and optical performances due to the external thermal and humidity impact, and an excellent shielding effectiveness of electromagnetic interference of nearly 2.3 dB. These excellent performances of the FTO thin films were strongly attributed to the design of the PS ECR-MOCVD, which enabled a uniform plasma environment resulting from a proper mixture of electromagnetic profiles and microwave power.« less

  17. Quantification of [11C]GB67 binding to cardiac alpha1-adrenoceptors with positron emission tomography: validation in pigs.

    PubMed

    Park-Holohan, So-Jin; Asselin, Marie-Claude; Turton, David R; Williams, Sharron L; Hume, Susan P; Camici, Paolo G; Rimoldi, Ornella E

    2008-09-01

    An increase in human cardiac alpha(1)-adrenoceptor (alpha(1)-AR) density is associated with various diseases such as myocardial ischemia, congestive heart failure, hypertrophic cardiomyopathy and hypertension. Positron emission tomography (PET) with an appropriate radioligand offers the possibility of imaging receptor function in the normal and diseased heart. [(11)C]GB67, an analogue of prazosin, has been shown in rats to have potential as a PET ligand with high selectivity to alpha(1)-AR. However, alpha(1)-AR density is up to ten times higher in rat heart compared to that in man. The aim of the present preclinical study was to extend the previous evaluation to a large mammal heart, where the alpha(1)-AR density is comparable to man, and to validate a method for quantification before PET studies in man. Seven [(11)C]GB67 PET studies, with weight-adjusted target dose of either 5.29 MBq kg(-1) (pilot, test-retest and baseline-predose studies) or 8.22 MBq kg(-1) (baseline-displacement studies), were performed in four anaesthetised pigs (39.5 +/- 3.9 kg). Total myocardial volume of distribution (V (T)) was estimated under different pharmacological conditions using compartmental analysis with a radiolabelled metabolite-corrected arterial plasma input function. A maximum possible blocking dose of 0.12 mumol kg(-1) of unlabeled GB67 was given 20 min before [(11)C]GB67 administration in the predose study and 45 min after administration of [(11)C]GB67 in the displacement study. In addition, [(15)O]CO (3,000 MBq) and [(15)O]H(2)O, with weight adjusted target dose of 10.57 MBq kg(-1), were also administered for estimation of blood volume recovery (RC) of the left ventricular cavity and myocardial perfusion (MBF), respectively. [(11)C]GB67 V (T) values (in ml cm(-3)) were estimated to be 24.2 +/- 5.5 (range, 17.3-31.3), 10.1 (predose) and 11.6 (displacement). MBF did not differ within each pig, including between baseline and predose conditions. Predose and displacement studies showed that specific binding of [(11)C]GB67 to myocardial alpha(1)-ARs accounts for approximately 50% of V (T). The present study offers a methodology for using [(11)C]GB67 as a radioligand to quantify human myocardial alpha(1)-ARs in clinical PET studies.

  18. Supercritical Water Process for the Chemical Recycling of Waste Plastics

    NASA Astrophysics Data System (ADS)

    Goto, Motonobu

    2010-11-01

    The development of chemical recycling of waste plastics by decomposition reactions in sub- and supercritical water is reviewed. Decomposition reactions proceed rapidly and selectively using supercritical fluids compared to conventional processes. Condensation polymerization plastics such as PET, nylon, and polyurethane, are relatively easily depolymerized to their monomers in supercritical water. The monomer components are recovered in high yield. Addition polymerization plastics such as phenol resin, epoxy resin, and polyethylene, are also decomposed to monomer components with or without catalysts. Recycling process of fiber reinforced plastics has been studied. Pilot scale or commercial scale plants have been developed and are operating with sub- and supercritical fluids.

  19. A pilot study of serotonergic modulation after long-term administration of oxytocin in autism spectrum disorder.

    PubMed

    Hirosawa, Tetsu; Kikuchi, Mitsuru; Ouchi, Yasuomi; Takahashi, Tetsuya; Yoshimura, Yuko; Kosaka, Hirotaka; Furutani, Naoki; Hiraishi, Hirotoshi; Fukai, Mina; Yokokura, Masamichi; Yoshikawa, Etsuji; Bunai, Tomoyasu; Minabe, Yoshio

    2017-05-01

    Oxytocin (OT) and the serotonergic system putatively play important roles in autism spectrum disorder (ASD) etiology and symptoms, but no direct neurobiological evidence exists for long-term OT administration effects on the brain's serotonergic system. This pilot study examined 10 male participants with ASD who were administered OT intranasally for 8-10 weeks in an open-label, single-arm, nonrandomized, and uncontrolled manner. Positron emission tomography (PET) with a radiotracer ( 11 C)-3-amino-4-(2-[(dimethylamino)methyl]phenylthio)benzonitrile ( 11 C-DASB) was used before and after OT treatment. The binding potential of serotonin transporter ( 11 C-DASB BP ND ) was then estimated. The main outcome measures were changes in 11 C-DASB BP ND and their correlation with changes in symptoms. ASD participants showed significantly elevated 11 C-DASB BP ND in the left inferior frontal gyrus extending to the left middle frontal gyrus. No significant correlation was found between the change in any clinical symptom and the change in 11 C-DASB BP ND . This report of a pilot study is the first describing long-term effects of OT on the brain's serotonin system in ASD. Additional randomized controlled studies must be conducted to confirm whether activation of the serotonergic system contributes to the prosocial effect of OT in people with ASD. Autism Res 2017, 10: 821-828. © 2017 International Society for Autism Research, Wiley Periodicals, Inc. © 2017 International Society for Autism Research, Wiley Periodicals, Inc.

  20. Use of Accelerometer Activity Monitors to Detect Changes in Pruritic Behaviors: Interim Clinical Data on 6 Dogs

    PubMed Central

    Thompson, Robin J.; Mickelsen, Scott L.; Smith, Spencer C.; Alvarenga, Isabella C.; Gross, Kathy L.

    2018-01-01

    Veterinarians and pet owners have limited ability to assess pruritic behaviors in dogs. This pilot study assessed the capacity of the Vetrax® triaxial accelerometer to measure these behaviors in six dogs with pruritus likely due to environmental allergens. Dogs wore the activity monitor for two weeks while consuming their usual pet food (baseline), then for eight weeks while consuming a veterinary-exclusive pet food for dogs with suspected non-food-related skin conditions (Hill’s Prescription Diet® Derm DefenseTM Canine dry food). Veterinarians and owners completed questionnaires during baseline, phase 1 (days 1–28) and phase 2 (days 29–56) without knowledge of the activity data. Continuous 3-axis accelerometer data was processed using proprietary behavior recognition algorithms and analyzed using general linear mixed models with false discovery rate-adjusted p values. Veterinarian-assessed overall clinical signs of pruritus were significantly predicted by scratching (β 0.176, p = 0.008), head shaking (β 0.197, p < 0.001) and sleep quality (β −0.154, p < 0.001), while owner-assessed quality of life was significantly predicted by scratching (β −0.103, p = 0.013) and head shaking (β −0.146, p < 0.001). Among dogs exhibiting pruritus signs eating the veterinary-exclusive food, the Vetrax® sensor provided an objective assessment of clinically relevant pruritic behaviors that agreed with owner and veterinarian reports. PMID:29337903

  1. Reducing the blame culture through clinical audit in nuclear medicine: a mixed methods study.

    PubMed

    Ross, P; Hubert, J; Wong, W L

    2017-02-01

    To identify the barriers and facilitators of doctors' engagement with clinical audit and to explore how and why these factors influenced doctors' decisions to engage with the NHS National Clinical Audit Programme. A single-embedded case study. Mixed methods sequential approach with explorative pilot study and follow-up survey. Pilot study comprised 13 semi-structured interviews with purposefully selected consultant doctors over a six-month period. Interview data coded and analysed using directed thematic content analysis with themes compared against the study's propositions. Themes derived from the pilot study informed the online survey question items. Exploratory factor analysis using STATA and descriptive statistical methods applied to summarise findings. Data triangulation techniques used to corroborate and validate findings across the different methodological techniques. NHS National PET-CT Clinical Audit Programme. Doctors reporting on the Audit Programme. Extent of engagement with clinical audit, factors that influence engagement with clinical audit. Online survey: 58/59 doctors responded (98.3%). Audit was found to be initially threatening (79%); audit was reassuring (85%); audit helped validate professional competence (93%); participation in audit improved reporting skills (76%). Three key factors accounted for 97.6% of the variance in survey responses: (1) perception of audit's usefulness, (2) a common purpose, (3) a supportive blame free culture of trust. Factor 1 influenced medical engagement most. The study documents performance feedback as a key facilitator of medical engagement with clinical audit. It found that medical engagement with clinical audit was associated with reduced levels of professional anxiety and higher levels of perceived self-efficacy.

  2. Feasibility of deep-inspiration breath-hold PET/CT with short-time acquisition: detectability for pulmonary lesions compared with respiratory-gated PET/CT.

    PubMed

    Yamashita, Shozo; Yokoyama, Kunihiko; Onoguchi, Masahisa; Yamamoto, Haruki; Hiko, Shigeaki; Horita, Akihiro; Nakajima, Kenichi

    2014-01-01

    Deep-inspiration breath-hold (DIBH) PET/CT with short-time acquisition and respiratory-gated (RG) PET/CT are performed for pulmonary lesions to reduce the respiratory motion artifacts, and to obtain more accurate standardized uptake value (SUV). DIBH PET/CT demonstrates significant advantages in terms of rapid examination, good quality of CT images and low radiation exposure. On the other hand, the image quality of DIBH PET is generally inferior to that of RG PET because of short-time acquisition resulting in poor signal-to-noise ratio. In this study, RG PET has been regarded as a gold standard, and its detectability between DIBH and RG PET studies was compared using each of the most optimal reconstruction parameters. In the phantom study, the most optimal reconstruction parameters for DIBH and RG PET were determined. In the clinical study, 19 cases were examined using each of the most optimal reconstruction parameters. In the phantom study, the most optimal reconstruction parameters for DIBH and RG PET were different. Reconstruction parameters of DIBH PET could be obtained by reducing the number of subsets for those of RG PET in the state of fixing the number of iterations. In the clinical study, high correlation in the maximum SUV was observed between DIBH and RG PET studies. The clinical result was consistent with that of the phantom study surrounded by air since most of the lesions were located in the low pulmonary radioactivity. DIBH PET/CT may be the most practical method which can be the first choice to reduce respiratory motion artifacts if the detectability of DIBH PET is equivalent with that of RG PET. Although DIBH PET may have limitations in suboptimal signal-to-noise ratio, most of the lesions surrounded by low background radioactivity could provide nearly equivalent image quality between DIBH and RG PET studies when each of the most optimal reconstruction parameters was used.

  3. The industrial water footprint of zippers.

    PubMed

    Zhang, Yin; Wu, Xiong Ying; Wang, Lai Li; Ding, Xue Mei

    2014-01-01

    Industrial production of apparel consumes large quantity of freshwater and discharges effluents that intensify the problem of freshwater shortage and water pollution. The industrial water footprint (IWF) of a piece of apparel includes the water footprint (WF) of the fabric, apparel accessories (e.g. zipper, fastener, sewing thread) and industrial production processes. The objective of this paper is to carry out a pilot study on IWF accounting for three kinds of typical zipper (i.e. metal zipper, polyethylene terephthalate (PET) zipper and polyoxymethylene copolymer (Co-POM) zipper) that are commonly used for apparel production. The results reveal that product output exerts a remarkable influence on zipper's average IWF. Metal zipper has the largest IWF and followed by Co-POM zipper and PET zipper. Painting, dyeing and primary processing are the top three water-consuming processes and contribute about 90% of the zipper's IWF. Painting consumes the largest amount of freshwater among all processes and occupies more than 50% of the zipper's IWF. In addition, the grey water footprint (WFgrey) provides the greatest contribution, more than 80%, to the zipper's IWF. Based on these results, this paper also provides several strategies aimed at water economization and pollution reduction during industrial production of zipper.

  4. Brentuximab vedotin and AVD followed by involved-site radiotherapy in early stage, unfavorable risk Hodgkin lymphoma.

    PubMed

    Kumar, Anita; Casulo, Carla; Yahalom, Joachim; Schöder, Heiko; Barr, Paul M; Caron, Philip; Chiu, April; Constine, Louis S; Drullinsky, Pamela; Friedberg, Jonathan W; Gerecitano, John F; Hamilton, Audrey; Hamlin, Paul A; Horwitz, Steven M; Jacob, Alexandra G; Matasar, Matthew J; McArthur, Gianna N; McCall, Susan J; Moskowitz, Alison J; Noy, Ariela; Palomba, Maria L; Portlock, Carol S; Straus, David J; VanderEls, Nicholas; Verwys, Stephanie L; Yang, Joanna; Younes, Anas; Zelenetz, Andrew D; Zhang, Zhigang; Moskowitz, Craig H

    2016-09-15

    This multicenter pilot study assessed the safety and efficacy of brentuximab vedotin (BV) and AVD (adriamycin, vinblastine, and dacarbazine) followed by 30 Gy involved site radiation therapy (ISRT). Patients with newly diagnosed, early stage classical Hodgkin lymphoma (HL) with unfavorable-risk features were treated with 4 cycles of BV and AVD. Patients who achieved a negative positron emission tomography (PET) scan (Deauville score of 1-3) received 30 Gy ISRT. Thirty patients received treatment and were assessable for toxicity. Twenty-nine patients completed 4 cycles of BV + AVD, and 25 patients BV + AVD + 30 Gy ISRT. No clinically significant noninfectious pneumonitis was observed. Serious adverse events (≥grade 3) were reported in 4 patients, including febrile neutropenia, peripheral neuropathy, and hypertension. After 2 and 4 cycles of BV + AVD, 90% (26 of 29) and 93% (27 or 29) of patients achieved a negative PET scan, respectively. Two patients with biopsy-proven primary refractory HL were treated off-study. All 25 patients who completed BV + AVD + ISRT achieved a complete response. With a median follow-up of 18.8 months, by intent to treat, the 1-year progression-free survival is 93.3% (95% confidence interval, 84-102). Overall, the treatment was well-tolerated with no evidence of significant pulmonary toxicity. The majority of patients (≥90%) achieved negative interim PET scans after 2 and 4 cycles of BV + AVD. Excluding the 2 primary refractory patients, all patients are disease free, suggesting that this is a highly active treatment program even in patients with substantial disease bulk. This trial was registered at www.clinicaltrials.gov as #NCT01868451. © 2016 by The American Society of Hematology.

  5. Usefulness of whole-body fluorine-18-fluorodeoxyglucose positron emission tomography in patients with large-vessel vasculitis: a systematic review.

    PubMed

    Treglia, Giorgio; Mattoli, Maria Vittoria; Leccisotti, Lucia; Ferraccioli, Gianfranco; Giordano, Alessandro

    2011-10-01

    The objective of this study is to systematically review the role of positron emission tomography (PET) and PET/computed tomography (PET/CT) with fluorine-18-fluorodeoxyglucose (FDG) in patients with large-vessel vasculitis (LVV). A comprehensive literature search of published studies through April 2011 in PubMed/MEDLINE and Scopus databases regarding whole-body FDG-PET and PET/CT in patients with LVV was performed. We identified 32 studies including 604 LVV patients. The main findings of these studies are presented. The conclusions are the following: (1) FDG-PET and PET/CT are useful imaging methods in the initial diagnosis and in the assessment of activity and extent of disease in patients with LVV; (2) the correlation between FDG-PET findings and serological levels of inflammatory markers, as well as the usefulness of FDG-PET and PET/CT in evaluating treatment response, remains unclear; (3) it appears that there is a superiority of FDG-PET and PET/CT over conventional imaging methods in the diagnosis of LVV, but not in assessing disease activity under immunosuppressive treatment, in predicting relapse or in evaluating vascular complications; and (4) given the heterogeneity between studies with regard to PET analysis and diagnostic criteria, a standardization of the technique is needed.

  6. Diagnostic performance of FDG PET or PET/CT in prosthetic infection after arthroplasty: a meta-analysis.

    PubMed

    Jin, H; Yuan, L; Li, C; Kan, Y; Hao, R; Yang, J

    2014-03-01

    The purpose of this study was to systematically review and perform a meta-analysis of published data regarding the diagnostic performance of positron emission tomography (PET) or PET/computed tomography (PET/CT) in prosthetic infection after arthroplasty. A comprehensive computer literature search of studies published through May 31, 2012 regarding PET or PET/CT in patients suspicious of prosthetic infection was performed in PubMed/MEDLINE, Embase and Scopus databases. Pooled sensitivity and specificity of PET or PET/CT in patients suspicious of prosthetic infection on a per prosthesis-based analysis were calculated. The area under the receiver-operating characteristic (ROC) curve was calculated to measure the accuracy of PET or PET/CT in patients with suspicious of prosthetic infection. Fourteen studies comprising 838 prosthesis with suspicious of prosthetic infection after arthroplasty were included in this meta-analysis. The pooled sensitivity of PET or PET/CT in detecting prosthetic infection was 86% (95% confidence interval [CI] 82-90%) on a per prosthesis-based analysis. The pooled specificity of PET or PET/CT in detecting prosthetic infection was 86% (95% CI 83-89%) on a per prosthesis-based analysis. The area under the ROC curve was 0.93 on a per prosthesis-based analysis. In patients suspicious of prosthetic infection, FDG PET or PET/CT demonstrated high sensitivity and specificity. FDG PET or PET/CT are accurate methods in this setting. Nevertheless, possible sources of false positive results and influcing factors should kept in mind.

  7. 18F-DCFPyL PET/CT in the Detection of Prostate Cancer at 60 and 120 Minutes: Detection Rate, Image Quality, Activity Kinetics, and Biodistribution.

    PubMed

    Wondergem, Maurits; van der Zant, Friso M; Knol, Remco J J; Lazarenko, Sergiy V; Pruim, Jan; de Jong, Igle J

    2017-11-01

    There is increasing interest in PET/CT with prostate-specific membrane antigen (PSMA) tracers for imaging of prostate cancer because of the higher detection rates of prostate cancer lesions than with PET/CT with choline. For 68 Ga-PSMA-11 tracers, late imaging at 180 min after injection instead of imaging at 45-60 min after injection improves the detection of prostate cancer lesions. For 18 F-DCFPyL, improved detection rates have recently been reported in a small pilot study. In this study, we report the effects of PET/CT imaging at 120 min after injection of 18 F-DCFPyL in comparison to images acquired at 60 min after injection in a larger clinical cohort of 66 consecutive patients with histopathologically proven prostate cancer. Methods: Images were acquired 60 and 120 min after injection of 18 F-DCFPyL. We report the positive lesions specified for anatomic locations (prostate, seminal vesicles, local lymph nodes, distant lymph nodes, bone, and others) at both time points by visual analysis, the image quality at both time points, and a semiquantitative analysis of the tracer activity in both prostate cancer lesions as well as normal tissues at both time points. Results: Our data showed a significantly increasing uptake of 18 F-DCFPyL between 60 and 120 min after injection in 203 lesions characteristic for prostate cancer (median, 10.78 vs. 12.86, P < 0.001, Wilcoxon signed-rank test). By visual analysis, 38.5% of all patients showed more lesions using images at 120 min after injection than using images at 60 min after injection, and in 9.2% a change in TNM staging was found. All lesions seen on images 60 min after injection were also visible on images 120 min after injection. A significantly better mean signal-to-noise ratio of 11.93 was found for images acquired 120 min after injection ( P < 0.001, paired t test; signal-to-noise ratio at 60 min after injection, 11.15). Conclusion: 18 F-DCFPyL PET/CT images at 120 min after injection yield a higher detection rate of prostate cancer characteristic lesions than images at 60 min after injection. Further studies are needed to elucidate the best imaging time point for 18 F-DCFPyL. © 2017 by the Society of Nuclear Medicine and Molecular Imaging.

  8. Colorectal cancer staging: comparison of whole-body PET/CT and PET/MR.

    PubMed

    Catalano, Onofrio A; Coutinho, Artur M; Sahani, Dushyant V; Vangel, Mark G; Gee, Michael S; Hahn, Peter F; Witzel, Thomas; Soricelli, Andrea; Salvatore, Marco; Catana, Ciprian; Mahmood, Umar; Rosen, Bruce R; Gervais, Debra

    2017-04-01

    Correct staging is imperative for colorectal cancer (CRC) since it influences both prognosis and management. Several imaging methods are used for this purpose, with variable performance. Positron emission tomography-magnetic resonance (PET/MR) is an innovative imaging technique recently employed for clinical application. The present study was undertaken to compare the staging accuracy of whole-body positron emission tomography-computed tomography (PET/CT) with whole-body PET/MR in patients with both newly diagnosed and treated colorectal cancer. Twenty-six patients, who underwent same day whole-body (WB) PET/CT and WB-PET/MR, were evaluated. PET/CT and PET/MR studies were interpreted by consensus by a radiologist and a nuclear medicine physician. Correlations with prior imaging and follow-up studies were used as the reference standard. Correct staging was compared between methods using McNemar's Chi square test. The two methods were in agreement and correct for 18/26 (69%) patients, and in agreement and incorrect for one patient (3.8%). PET/MR and PET/CT stages for the remaining 7/26 patients (27%) were discordant, with PET/MR staging being correct in all seven cases. PET/MR significantly outperformed PET/CT overall for accurate staging (P = 0.02). PET/MR outperformed PET/CT in CRC staging. PET/MR might allow accurate local and distant staging of CRC patients during both at the time of diagnosis and during follow-up.

  9. Reducing the blame culture through clinical audit in nuclear medicine: a mixed methods study

    PubMed Central

    Ross, P; Hubert, J

    2017-01-01

    Objectives To identify the barriers and facilitators of doctors’ engagement with clinical audit and to explore how and why these factors influenced doctors’ decisions to engage with the NHS National Clinical Audit Programme. Design A single-embedded case study. Mixed methods sequential approach with explorative pilot study and follow-up survey. Pilot study comprised 13 semi-structured interviews with purposefully selected consultant doctors over a six-month period. Interview data coded and analysed using directed thematic content analysis with themes compared against the study’s propositions. Themes derived from the pilot study informed the online survey question items. Exploratory factor analysis using STATA and descriptive statistical methods applied to summarise findings. Data triangulation techniques used to corroborate and validate findings across the different methodological techniques. Setting NHS National PET-CT Clinical Audit Programme. Participants Doctors reporting on the Audit Programme. Main Outcome measures Extent of engagement with clinical audit, factors that influence engagement with clinical audit. Results Online survey: 58/59 doctors responded (98.3%). Audit was found to be initially threatening (79%); audit was reassuring (85%); audit helped validate professional competence (93%); participation in audit improved reporting skills (76%). Three key factors accounted for 97.6% of the variance in survey responses: (1) perception of audit’s usefulness, (2) a common purpose, (3) a supportive blame free culture of trust. Factor 1 influenced medical engagement most. Conclusions The study documents performance feedback as a key facilitator of medical engagement with clinical audit. It found that medical engagement with clinical audit was associated with reduced levels of professional anxiety and higher levels of perceived self-efficacy. PMID:28210493

  10. Robust Intratumor Partitioning to Identify High-Risk Subregions in Lung Cancer: A Pilot Study.

    PubMed

    Wu, Jia; Gensheimer, Michael F; Dong, Xinzhe; Rubin, Daniel L; Napel, Sandy; Diehn, Maximilian; Loo, Billy W; Li, Ruijiang

    2016-08-01

    To develop an intratumor partitioning framework for identifying high-risk subregions from (18)F-fluorodeoxyglucose positron emission tomography (FDG-PET) and computed tomography (CT) imaging and to test whether tumor burden associated with the high-risk subregions is prognostic of outcomes in lung cancer. In this institutional review board-approved retrospective study, we analyzed the pretreatment FDG-PET and CT scans of 44 lung cancer patients treated with radiation therapy. A novel, intratumor partitioning method was developed, based on a 2-stage clustering process: first at the patient level, each tumor was over-segmented into many superpixels by k-means clustering of integrated PET and CT images; next, tumor subregions were identified by merging previously defined superpixels via population-level hierarchical clustering. The volume associated with each of the subregions was evaluated using Kaplan-Meier analysis regarding its prognostic capability in predicting overall survival (OS) and out-of-field progression (OFP). Three spatially distinct subregions were identified within each tumor that were highly robust to uncertainty in PET/CT co-registration. Among these, the volume of the most metabolically active and metabolically heterogeneous solid component of the tumor was predictive of OS and OFP on the entire cohort, with a concordance index or CI of 0.66-0.67. When restricting the analysis to patients with stage III disease (n=32), the same subregion achieved an even higher CI of 0.75 (hazard ratio 3.93, log-rank P=.002) for predicting OS, and a CI of 0.76 (hazard ratio 4.84, log-rank P=.002) for predicting OFP. In comparison, conventional imaging markers, including tumor volume, maximum standardized uptake value, and metabolic tumor volume using threshold of 50% standardized uptake value maximum, were not predictive of OS or OFP, with CI mostly below 0.60 (log-rank P>.05). We propose a robust intratumor partitioning method to identify clinically relevant, high-risk subregions in lung cancer. We envision that this approach will be applicable to identifying useful imaging biomarkers in many cancer types. Copyright © 2016 Elsevier Inc. All rights reserved.

  11. Robust Intratumor Partitioning to Identify High-Risk Subregions in Lung Cancer: A Pilot Study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wu, Jia; Gensheimer, Michael F.; Dong, Xinzhe

    2016-08-01

    Purpose: To develop an intratumor partitioning framework for identifying high-risk subregions from {sup 18}F-fluorodeoxyglucose positron emission tomography (FDG-PET) and computed tomography (CT) imaging and to test whether tumor burden associated with the high-risk subregions is prognostic of outcomes in lung cancer. Methods and Materials: In this institutional review board–approved retrospective study, we analyzed the pretreatment FDG-PET and CT scans of 44 lung cancer patients treated with radiation therapy. A novel, intratumor partitioning method was developed, based on a 2-stage clustering process: first at the patient level, each tumor was over-segmented into many superpixels by k-means clustering of integrated PET andmore » CT images; next, tumor subregions were identified by merging previously defined superpixels via population-level hierarchical clustering. The volume associated with each of the subregions was evaluated using Kaplan-Meier analysis regarding its prognostic capability in predicting overall survival (OS) and out-of-field progression (OFP). Results: Three spatially distinct subregions were identified within each tumor that were highly robust to uncertainty in PET/CT co-registration. Among these, the volume of the most metabolically active and metabolically heterogeneous solid component of the tumor was predictive of OS and OFP on the entire cohort, with a concordance index or CI of 0.66-0.67. When restricting the analysis to patients with stage III disease (n=32), the same subregion achieved an even higher CI of 0.75 (hazard ratio 3.93, log-rank P=.002) for predicting OS, and a CI of 0.76 (hazard ratio 4.84, log-rank P=.002) for predicting OFP. In comparison, conventional imaging markers, including tumor volume, maximum standardized uptake value, and metabolic tumor volume using threshold of 50% standardized uptake value maximum, were not predictive of OS or OFP, with CI mostly below 0.60 (log-rank P>.05). Conclusion: We propose a robust intratumor partitioning method to identify clinically relevant, high-risk subregions in lung cancer. We envision that this approach will be applicable to identifying useful imaging biomarkers in many cancer types.« less

  12. Pilot Studies With BGO Scintillators Coupled to Low-Noise, Large-Area, SiPM Arrays

    NASA Astrophysics Data System (ADS)

    González, Antonio J.; Sánchez, Filomeno; Majewski, Stan; Parkhurst, Philip; Vaigneur, Keith; Benlloch, José M.

    2016-10-01

    Despite the fact that timing capabilities for devices based on BGO are limited when compared with LYSO or LSO based systems, the cost of BGO is considerably lower and could thus, be an option for devices with high scintillator volumes (as in the case of nuclear medicine scanners), but also in smaller dedicated imagers. Recently, many studies have been carried out in order to determine the potential capabilities of BGO for PET and SPECT applications, where BGO scintillator crystals have been coupled to SiPM photosensor devices. However, so far these studies have only been done on small-size BGO samples. In this work, we have studied three different BGO size configurations, coupled to a 12 × 12 low-noise SiPM array. Each SiPM has an active area of 3 × 3 mm2 with a pixel pitch of 4.2 mm. A special charge division network providing information for each row and column output of the SiPM array has been used. The first tested BGO configuration has 2.5 mm crystal pixel pitch and 10 mm thickness, while the second makes use of smaller 1.5 mm pixels with 1.67 mm pitch but only 3 mm thick. The third evaluated configuration provided limited photon depth of interaction (DOI) information by using two staggered layers of BGO pixels also with 2.5 mm pitch and with a total thickness of 20 mm. Performances of these configurations in terms of spatial and energy resolutions have been determined. Energy resolution as good as 14.2% was obtained. Our results indicate that single layer crystal arrays with pixel values as low as 1.5 mm or two staggered layers with 2.5 mm pitch are well suited for PET applications, such as low-cost and high performance dedicated PET systems or large systems.

  13. Pet Ownership among Homeless Youth: Associations with Mental Health, Service Utilization and Housing Status

    PubMed Central

    Rhoades, Harmony; Winetrobe, Hailey; Rice, Eric

    2014-01-01

    As many as 25% of homeless persons have pets. To our knowledge, pet ownership has not been studied quantitatively with homeless youth. This study examined pet ownership among 398 homeless youth utilizing two Los Angeles drop-in centers. Twenty-three percent of homeless youth had a pet. The majority of pet owners reported that their pets kept them company and made them feel loved; nearly half reported that their pets made it more difficult to stay in a shelter. Pet owners reported fewer symptoms of depression and loneliness than their non-pet owning peers. Pet ownership was associated with decreased utilization of housing and job-finding services, and decreased likelihood of currently staying in a shelter. These findings elucidate many of the positive benefits of pet ownership for homeless youth, but importantly highlight that pet ownership may negatively impact housing options. Housing and other services must be sensitive to the needs of homeless youth with pets. PMID:24728815

  14. Pet ownership among homeless youth: associations with mental health, service utilization and housing status.

    PubMed

    Rhoades, Harmony; Winetrobe, Hailey; Rice, Eric

    2015-04-01

    As many as 25 % of homeless persons have pets. To our knowledge, pet ownership has not been studied quantitatively with homeless youth. This study examined pet ownership among 398 homeless youth utilizing two Los Angeles drop-in centers. Twenty-three percent of homeless youth had a pet. The majority of pet owners reported that their pets kept them company and made them feel loved; nearly half reported that their pets made it more difficult to stay in a shelter. Pet owners reported fewer symptoms of depression and loneliness than their non-pet owning peers. Pet ownership was associated with decreased utilization of housing and job-finding services, and decreased likelihood of currently staying in a shelter. These findings elucidate many of the positive benefits of pet ownership for homeless youth, but importantly highlight that pet ownership may negatively impact housing options. Housing and other services must be sensitive to the needs of homeless youth with pets.

  15. Childhood Attachment to Pets: Associations between Pet Attachment, Attitudes to Animals, Compassion, and Humane Behaviour

    PubMed Central

    Hawkins, Roxanne D.; Williams, Joanne M.

    2017-01-01

    Attachment to pets has an important role in children’s social, emotional, and cognitive development, mental health, well-being, and quality of life. This study examined associations between childhood attachment to pets and caring and friendship behaviour, compassion, and attitudes towards animals. This study also examined socio-demographic differences, particularly pet ownership and pet type. A self-report survey of over one thousand 7 to 12 year-olds in Scotland, UK, revealed that the majority of children are strongly attached to their pets, but attachment scores differ depending on pet type and child gender. Analysis revealed that attachment to pets is facilitated by compassion and caring and pet-directed friendship behaviours and that attachment to pets significantly predicts positive attitudes towards animals. The findings have implications for the promotion of prosocial and humane behaviour. Encouraging children to participate in pet care behaviour may promote attachment between children and their pet, which in turn may have a range of positive outcomes for both children (such as reduced aggression, better well-being, and quality of life) and pets (such as humane treatment). This study enhances our understanding of childhood pet attachment and has implications for humane education and promoting secure emotional attachments in childhood. PMID:28481256

  16. Childhood Attachment to Pets: Associations between Pet Attachment, Attitudes to Animals, Compassion, and Humane Behaviour.

    PubMed

    Hawkins, Roxanne D; Williams, Joanne M; Scottish Society For The Prevention Of Cruelty To Animals Scottish Spca

    2017-05-06

    Attachment to pets has an important role in children's social, emotional, and cognitive development, mental health, well-being, and quality of life. This study examined associations between childhood attachment to pets and caring and friendship behaviour, compassion, and attitudes towards animals. This study also examined socio-demographic differences, particularly pet ownership and pet type. A self-report survey of over one thousand 7 to 12 year-olds in Scotland, UK, revealed that the majority of children are strongly attached to their pets, but attachment scores differ depending on pet type and child gender. Analysis revealed that attachment to pets is facilitated by compassion and caring and pet-directed friendship behaviours and that attachment to pets significantly predicts positive attitudes towards animals. The findings have implications for the promotion of prosocial and humane behaviour. Encouraging children to participate in pet care behaviour may promote attachment between children and their pet, which in turn may have a range of positive outcomes for both children (such as reduced aggression, better well-being, and quality of life) and pets (such as humane treatment). This study enhances our understanding of childhood pet attachment and has implications for humane education and promoting secure emotional attachments in childhood.

  17. Family pet ownership during childhood: findings from a UK birth cohort and implications for public health research.

    PubMed

    Westgarth, Carri; Heron, Jon; Ness, Andy R; Bundred, Peter; Gaskell, Rosalind M; Coyne, Karen P; German, Alexander J; McCune, Sandra; Dawson, Susan

    2010-10-01

    In developed nations, approximately half of household environments contain pets. Studies of Human-Animal Interaction (HAI) have proposed that there are health benefits and risks associated with pet ownership. However, accurately demonstrating and understanding these relationships first requires a better knowledge of factors associated with ownership of different pet types. A UK birth cohort, the Avon Longitudinal Study of Parents and Children (ALSPAC), were used to collect pet ownership data from the mothers, from gestation to child age 10 years old. 14,663 children were included in the study, of which mothers of 13,557 reported pet information at gestation, and 7,800 by age 10. Pet types recorded include cat, dog, rabbit, rodent, bird, fish and tortoise/turtle. The dataset also contains a number of demographic, socioeconomic and behavioural variables relevant to human health behaviour. Logistic regression was used to build multivariable models for ownership of each pet type at age 7 years. Family pet ownership increased during childhood, in particular rabbits, rodents and fish. A number of socioeconomic and demographic factors were associated with ownership of different pet types and the effects differed depending on the pet type studied. Variables which require consideration by researchers include gender, presence of older siblings, ethnicity, maternal and paternal education, maternal and paternal social class, maternal age, number of people in the household, house type, and concurrent ownership of other pets. Whether the mother had pets during her childhood was a strong predictor of pet ownership in all models. In HAI studies, care should be taken to control for confounding factors, and to treat each pet type individually. ALSPAC and other similar birth cohorts can be considered a potential resource for research into the effects of pet ownership during childhood.

  18. Family Pet Ownership during Childhood: Findings from a UK Birth Cohort and Implications for Public Health Research

    PubMed Central

    Westgarth, Carri; Heron, Jon; Ness, Andy R.; Bundred, Peter; Gaskell, Rosalind M.; Coyne, Karen P.; German, Alexander J.; McCune, Sandra; Dawson, Susan

    2010-01-01

    In developed nations, approximately half of household environments contain pets. Studies of Human-Animal Interaction (HAI) have proposed that there are health benefits and risks associated with pet ownership. However, accurately demonstrating and understanding these relationships first requires a better knowledge of factors associated with ownership of different pet types. A UK birth cohort, the Avon Longitudinal Study of Parents and Children (ALSPAC), were used to collect pet ownership data from the mothers, from gestation to child age 10 years old. 14,663 children were included in the study, of which mothers of 13,557 reported pet information at gestation, and 7,800 by age 10. Pet types recorded include cat, dog, rabbit, rodent, bird, fish and tortoise/turtle. The dataset also contains a number of demographic, socioeconomic and behavioural variables relevant to human health behaviour. Logistic regression was used to build multivariable models for ownership of each pet type at age 7 years. Family pet ownership increased during childhood, in particular rabbits, rodents and fish. A number of socioeconomic and demographic factors were associated with ownership of different pet types and the effects differed depending on the pet type studied. Variables which require consideration by researchers include gender, presence of older siblings, ethnicity, maternal and paternal education, maternal and paternal social class, maternal age, number of people in the household, house type, and concurrent ownership of other pets. Whether the mother had pets during her childhood was a strong predictor of pet ownership in all models. In HAI studies, care should be taken to control for confounding factors, and to treat each pet type individually. ALSPAC and other similar birth cohorts can be considered a potential resource for research into the effects of pet ownership during childhood. PMID:21139856

  19. Understanding the context for pet cat and dog feeding and exercising behaviour among pet owners in Ireland: a qualitative study.

    PubMed

    Downes, Martin J; Devitt, Catherine; Downes, Marie T; More, Simon J

    2017-01-01

    Pet cat and dog obesity contributes to increased risk of several diseases, including cancer and diabetes mellitus as well as a worsening of orthopaedic problems, and a reduction in survival rate. This study aims to develop a better understanding of cat and dog owners' self-reported beliefs and factors that influence owner behaviour around feeding and exercising their pet cat or dog, as there is a lack of in-depth understanding in this area. Seven focus group discussions, with 43 pet owners in total, were conducted. Pet owners often reported a perceived a low level of control over feeding; often undermined by other people feeding of their pet, their pets begging for food, and their pets attitude towards food. Treats were used in the absence of owner control over pet begging and emotional attachment, and to influence pet behaviour. The majority of participants had positive attitudes to pet exercise, which could be related to pet specific requirements, especially differences in cats and dogs. There were some negative experiences of stress associated with dog walking and fears over aggressive confrontations with other dogs. Feeding one's pet is influenced by beliefs about pet specific needs, pet food and pet health, pet owners' perceived control over feeding, and the implications for the pet owner. Pet exercise is influenced by beliefs about pet specific exercise needs, and the implications of exercising one's pet for the pet owner. Understanding owner behaviours on feeding and exercise allows for a more targeted approach to preventing and treating pet obesity.

  20. Evaluation of PET Scanner Performance in PET/MR and PET/CT Systems: NEMA Tests.

    PubMed

    Demir, Mustafa; Toklu, Türkay; Abuqbeitah, Mohammad; Çetin, Hüseyin; Sezgin, H Sezer; Yeyin, Nami; Sönmezoğlu, Kerim

    2018-02-01

    The aim of the present study was to compare the performance of positron emission tomography (PET) component of PET/computed tomography (CT) with new emerging PET/magnetic resonance (MR) of the same vendor. According to National Electrical Manufacturers Association NU2-07, five separate experimental tests were performed to evaluate the performance of PET scanner of General Electric GE company; SIGNATM model PET/MR and GE Discovery 710 model PET/CT. The main investigated aspects were spatial resolution, sensitivity, scatter fraction, count rate performance, image quality, count loss and random events correction accuracy. The findings of this study demonstrated superior sensitivity (~ 4 folds) of PET scanner in PET/MR compared to PET/CT system. Image quality test exhibited higher contrast in PET/MR (~ 9%) compared with PET/CT. The scatter fraction of PET/MR was 43.4% at noise equivalent count rate (NECR) peak of 218 kcps and the corresponding activity concentration was 17.7 kBq/cc. Whereas the scatter fraction of PET/CT was found as 39.2% at NECR peak of 72 kcps and activity concentration of 24.3 kBq/cc. The percentage error of the random event correction accuracy was 3.4% and 3.1% in PET/MR and PET/CT, respectively. It was concluded that PET/MR system is about 4 times more sensitive than PET/CT, and the contrast of hot lesions in PET/MR was ~ 9% higher than PET/CT. These outcomes also emphasize the possibility to achieve excellent clinical PET images with low administered dose and/or a short acquisition time in PET/MR.

  1. Comparison of 18F-FDG PET/CT and PET/MRI in patients with multiple myeloma

    PubMed Central

    Sachpekidis, Christos; Hillengass, Jens; Goldschmidt, Hartmut; Mosebach, Jennifer; Pan, Leyun; Schlemmer, Heinz-Peter; Haberkorn, Uwe; Dimitrakopoulou-Strauss, Antonia

    2015-01-01

    PET/MRI represents a promising hybrid imaging modality with several potential clinical applications. Although PET/MRI seems highly attractive in the diagnostic approach of multiple myeloma (MM), its role has not yet been evaluated. The aims of this prospective study are to evaluate the feasibility of 18F-FDG PET/MRI in detection of MM lesions, and to investigate the reproducibility of bone marrow lesions detection and quantitative data of 18F-FDG uptake between the functional (PET) component of PET/CT and PET/MRI in MM patients. The study includes 30 MM patients. All patients initially underwent 18F-FDG PET/CT (60 min p.i.), followed by PET/MRI (120 min p.i.). PET/CT and PET/MRI data were assessed and compared based on qualitative (lesion detection) and quantitative (SUV) evaluation. The hybrid PET/MRI system provided good image quality in all cases without artefacts. PET/MRI identified 65 of the 69 lesions, which were detectable with PET/CT (94.2%). Quantitative PET evaluations showed the following mean values in MM lesions: SUVaverage=5.5 and SUVmax=7.9 for PET/CT; SUVaverage=3.9 and SUVmax=5.8 for PET/MRI. Both SUVaverage and SUVmax were significantly higher on PET/CT than on PET/MRI. Spearman correlation analysis demonstrated a strong correlation between both lesional SUVaverage (r=0.744) and lesional SUVmax (r=0.855) values derived from PET/CT and PET/MRI. Regarding detection of myeloma skeletal lesions, PET/MRI exhibited equivalent performance to PET/CT. In terms of tracer uptake quantitation, a significant correlation between the two techniques was demonstrated, despite the statistically significant differences in lesional SUVs between PET/CT and PET/MRI. PMID:26550538

  2. Thermal (dis)comfort experienced from physiological movements across indoor, transitional and outdoor spaces in Singapore: A pilot study

    NASA Astrophysics Data System (ADS)

    Li Heng, Su; Chow, Winston

    2017-04-01

    Human thermal comfort research is important as climate discomfort can adversely affect both health and work productivity in cities; however, such biometeorological work in low-latitude urban areas is still relatively unstudied hitherto. In the tropical metropolis of Singapore, a suite of policies have been implemented aimed at improving environmental sustainability via increasing car-free commutes and pedestrian movement during work/school journeys, with the consequence that individuals will likely have increased personal exposure through a variety of spaces (and climates) during typical daily activities. As such, research into exploring the thermal (dis)comfort experienced during pedestrian movements across these indoor, outdoor and transitional (semi-outdoor) spaces would yield interesting applied biometerological insights. This pilot study thus investigates how pedestrian thermal comfort varies spatially across a university campus, and how the physical intensity of pedestrian travel affects thermal comfort across these spaces. Over a 10-week period, we profiled six students for both their objective and subjective pedestrian thermal comfort during traverses across different spaces. Data were obtained through use of (a.) of a heat stress sensor, (b.) a fitness tracker, and (b.) a questionnaire survey to record traverse measurements of the microclimate, their physiological data, and their perceived microclimate comfort respectively. Measured climate and physiological data were used to derive commonly-used thermal comfort indices like wet-bulb globe temperature (WBGT) and physiological equivalent temperature (PET). Further, interviews were conducted with all six subjects at the end of the fieldwork period to ascertain details on individual acclimatization behavior and adaptation strategies. The results indicate that (a.) more than 50% of the microclimatic conditions within each indoor, semi-outdoor, and outdoor space exceeded heat stress thresholds of both PET and WBGT, and that participants often were at "high" risk of heat stress from pedestrian movement; (b.) participants were most comfortable with humidity sensations across all spaces compared to other microclimate sensations (e.g. wind, heat, sun); (c.) correlation between microclimate sensation and WBGT varied across participants and across spaces, with stronger correlation between sun sensation votes and WBGT for most participants, and (d.) heart rates of individuals were not significant in estimating and predicting PET for activities such as pedestrian walking. Present results confirm that WBGT applies better to hot climates and outdoor thermal comfort, but not so for hot, humid climates and indoor thermal comfort. Self-reported (subjective) thermal comfort also differed from measured (objective) thermal comfort and across participants because acclimatized individuals can have different sensitivities and acceptance towards (dis)comfort arising from pedestrian movement across spaces. Finally, we suggest that future pedestrian thermal comfort studies employ longitudinal studies and traverse measurements to consider the critical aspects of thermal history and individual sensitivities to on (dis)comfort levels.

  3. The role of Fluorine-18-Fluorodeoxyglucose positron emission tomography in staging and restaging of patients with osteosarcoma.

    PubMed

    Quartuccio, Natale; Treglia, Giorgio; Salsano, Marco; Mattoli, Maria Vittoria; Muoio, Barbara; Piccardo, Arnoldo; Lopci, Egesta; Cistaro, Angelina

    2013-06-01

    The objective of this study is to systematically review the role of positron emission tomography (PET) and PET/computed tomography (PET/CT) with Fluorine-18-Fluorodeoxyglucose (FDG) in patients with osteosarcoma (OS). A comprehensive literature search of published studies through October 10(th), 2012 in PubMed/MEDLINE, Embase and Scopus databases regarding whole-body FDG-PET and FDG-PET/CT in patients with OS was performed. We identified 13 studies including 289 patients with OS. With regard to the staging and restaging of OS, the diagnostic performance of FDG-PET and PET/CT seem to be high; FDG-PET and PET/CT seem to be superior to bone scintigraphy and conventional imaging methods in detecting bone metastases; conversely, spiral CT seems to be superior to FDG-PET in detecting pulmonary metastases from OS. Metabolic imaging may provide additional information in the evaluation of OS patients. The combination of FDG-PET or FDG-PET/CT with conventional imaging methods seems to be a valuable tool in the staging and restaging of OS and may have a relevant impact on the treatment planning.

  4. [Microeconomics of introduction of a PET system based on the revised Japanese National Insurance reimbursement system].

    PubMed

    Abe, Katsumi; Kosuda, Shigeru; Kusano, Shoichi; Nagata, Masayoshi

    2003-11-01

    It is crucial to evaluate an annual balance before-hand when an institution installs a PET system because the revised Japanese national insurance reimbursement system set the cost of a FDG PET study as 75,000 yen. A break-even point was calculated in an 8-hour or a 24-hour operation of a PET system, based on the total costs reported. The break-even points were as follows: 13.4, 17.7, 22.1 studies per day for the 1 cyclotron-1 PET camera, 1 cyclotron-2 PET cameras, 1 cyclotron-3 PET cameras system, respectively, in an ordinary PET system operation of 8 hours. The break-even points were 19.9, 25.5, 31.2 studies per day for the 1 cyclotron-1 PET camera, 1 cyclotron-2 PET cameras, 1 cyclotron-3 PET cameras system, respectively, in a full PET system operation of 24 hours. The results indicate no profit would accrue in an ordinary PET system operation of 8 hours. The annual profit and break-even point for the total cost including the initial investment would be respectively 530 million yen and 2.8 years in a 24-hour operation with 1 cyclotron-3 PET cameras system.

  5. Prevalence and malignancy risk of focal colorectal incidental uptake detected by (18)F-FDG-PET or PET/CT: a meta-analysis.

    PubMed

    Treglia, Giorgio; Taralli, Silvia; Salsano, Marco; Muoio, Barbara; Sadeghi, Ramin; Giovanella, Luca

    2014-06-01

    The aim of the study was to meta-analyze published data about prevalence and malignancy risk of focal colorectal incidentalomas (FCIs) detected by Fluorine-18-Fluorodeoxyglucose positron emission tomography or positron emission tomography/computed tomography ((18)F-FDG-PET or PET/CT). A comprehensive computer literature search of studies published through July 31(st) 2012 regarding FCIs detected by (18)F-FDG-PET or PET/CT was performed. Pooled prevalence of patients with FCIs and risk of malignant or premalignant FCIs after colonoscopy or histopathology verification were calculated. Furthermore, separate calculations for geographic areas were performed. Finally, average standardized uptake values (SUV) in malignant, premalignant and benign FCIs were reported. Thirty-two studies comprising 89,061 patients evaluated by (18)F-FDG-PET or PET/CT were included. The pooled prevalence of FCIs detected by (18)F-FDG-PET or PET/CT was 3.6% (95% confidence interval [95% CI]: 2.6-4.7%). Overall, 1,044 FCIs detected by (18)F-FDG-PET or PET/CT underwent colonoscopy or histopathology evaluation. Pooled risk of malignant or premalignant lesions was 68% (95% CI: 60-75%). Risk of malignant and premalignant FCIs in Asia-Oceania was lower compared to that of Europe and America. A significant overlap in average SUV was found between malignant, premalignant and benign FCIs. FCIs are observed in a not negligible number of patients who undergo (18)F-FDG-PET or PET/CT studies with a high risk of malignant or premalignant lesions. SUV is not reliable as a tool to differentiate between malignant, premalignant and benign FCIs. Further investigation is warranted whenever FCIs are detected by (18)F-FDG-PET or PET/CT.

  6. Prevalence and malignancy risk of focal colorectal incidental uptake detected by 18F-FDG-PET or PET/CT: a meta-analysis

    PubMed Central

    Treglia, Giorgio; Taralli, Silvia; Salsano, Marco; Muoio, Barbara; Sadeghi, Ramin; Giovanella, Luca

    2014-01-01

    Background The aim of the study was to meta-analyze published data about prevalence and malignancy risk of focal colorectal incidentalomas (FCIs) detected by Fluorine-18-Fluorodeoxyglucose positron emission tomography or positron emission tomography/computed tomography (18F-FDG-PET or PET/CT). Methods A comprehensive computer literature search of studies published through July 31st 2012 regarding FCIs detected by 18F-FDG-PET or PET/CT was performed. Pooled prevalence of patients with FCIs and risk of malignant or premalignant FCIs after colonoscopy or histopathology verification were calculated. Furthermore, separate calculations for geographic areas were performed. Finally, average standardized uptake values (SUV) in malignant, premalignant and benign FCIs were reported. Results Thirty-two studies comprising 89,061 patients evaluated by 18F-FDG-PET or PET/CT were included. The pooled prevalence of FCIs detected by 18F-FDG-PET or PET/CT was 3.6% (95% confidence interval [95% CI]: 2.6–4.7%). Overall, 1,044 FCIs detected by 18F-FDG-PET or PET/CT underwent colonoscopy or histopathology evaluation. Pooled risk of malignant or premalignant lesions was 68% (95% CI: 60–75%). Risk of malignant and premalignant FCIs in Asia-Oceania was lower compared to that of Europe and America. A significant overlap in average SUV was found between malignant, premalignant and benign FCIs. Conclusions FCIs are observed in a not negligible number of patients who undergo 18F-FDG-PET or PET/CT studies with a high risk of malignant or premalignant lesions. SUV is not reliable as a tool to differentiate between malignant, premalignant and benign FCIs. Further investigation is warranted whenever FCIs are detected by 18F-FDG-PET or PET/CT. PMID:24991198

  7. Pet ownership and adolescent health: cross-sectional population study.

    PubMed

    Mathers, Megan; Canterford, Louise; Olds, Tim; Waters, Elizabeth; Wake, Melissa

    2010-12-01

    To determine whether adolescent health and well-being are associated with having a pet in the household (any pet, or specifically dogs, cats or horses/ponies) or average daily time spent caring for/playing with pet(s). Design, setting and participants--Cross-sectional data from the third wave of the Health of Young Victorians Study (HOYVS), a school-based population study in Victoria, Australia. Predictors--Adolescent-reported pet ownership and average daily time spent caring for/playing with pet(s). Outcomes--Self-reported quality of life (KIDSCREEN); average 4-day daily physical activity level from a computerised diary; parent-proxy and self-reported physical and psychosocial health status (PedsQL); measured BMI status (not overweight, overweight, obese) and blood pressure. Statistical Analysis--Regression methods, adjusted for socio-demographic factors, and non-parametric methods. Household pet data were available for 928 adolescents (466 boys; mean age of 15.9 (SD 1.2) years). Most adolescents (88.7%) reported having a pet in their household. Of these, 75.1% reported no activity involving pets over the surveyed days. It appeared that neither owning a pet nor time spent caring for/playing with a pet was related, positively or negatively, to adolescent health or well-being. Despite high rates of pet ownership, adolescents had little interaction with pets. It appears that owning a pet and time spent caring for/playing with a pet was not clearly associated with adolescents' health or well-being. © 2010 The Authors. Journal of Paediatrics and Child Health © 2010 Paediatrics and Child Health Division (Royal Australasian College of Physicians).

  8. Approaches using molecular imaging technology - use of PET in clinical microdose studies§

    PubMed Central

    Wagner, Claudia C; Langer, Oliver

    2013-01-01

    Positron emission tomography (PET) imaging uses minute amounts of radiolabeled drug tracers and thereby meets the criteria for clinical microdose studies. The advantage of PET, when compared to other analytical methods used in microdose studies, is that the pharmacokinetics (PK) of a drug can be determined in the tissue targeted for drug treatment. PET microdosing already offers interesting applications in clinical oncology and in the development of central nervous system pharmaceuticals and is extending its range of application to many other fields of pharmaceutical medicine. Although requirements for preclinical safety testing for microdose studies have been cut down by regulatory authorities, radiopharmaceuticals increasingly need to be produced under good manufacturing practice (GMP) conditions, which increases the costs of PET microdosing studies. Further challenges in PET microdosing include combining PET with other ultrasensitive analytical methods, such as accelerator mass spectrometry (AMS), to gain plasma PK data of drugs, beyond the short PET examination periods. Finally, conducting clinical PET studies with radiolabeled drugs both at micro- and therapeutic doses is encouraged to answer the question of dose linearity in clinical microdosing. PMID:20887762

  9. SU-F-R-27: Use Local Shape Descriptor Based On Geodesic Distance to Predict Survival in Non-Small Cell Lung Cancer After Radiotherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang, H; Yan, L; Huang, K

    2016-06-15

    Purpose: The shape of the Positron Emission Tomography (PET) image represents the heterogeneity of tumor growth in various directions, and thus could be associated with tumor malignancy. We have proposed a median geodesic distance (MGD) to represent the local complexity of the shape and use a normalized MGD (NMGD) to quantify the shape, and found a potential correlation of NMGD to survival in a 20-patient pilot study. This study was to verify the finding in a larger patient cohort. Methods: Geodesic distance of two vertices on a surface is defined as the shortest path on the surface connecting the twomore » vertices. The MGD was calculated for each vertex on the surface to display the local complexity of the shape. The NMGD was determined as: NMGD = 100*standard deviation(MGDs)/mean(MGDs). We applied the NMGD to 40 NSCLC patients who were enrolled in prospective PET image protocols and received radiotherapy. Each patient had a pre-treatment PET scan with the resolution of 4mm*4mm*5mm. Tumors were contoured by a professional radiation oncologist and triangulation meshes were built up based on the contours. Results: The mean and standard deviation of NMGD was 6.4±3.0. The OS was 33.1±16.9 months for low NMGD group, and 15.4±15.6 months for the high NMGD group. The low NMGD group had significant better OS than the high NMGD group (p=0.0013). Conclusion: NMGD could be used as a shape biomarker to predict survival and the MGD could be combined with image texture in future to increase prediction accuracy. This study was supported by Award Number 1R01CA166948 from the NIH and National Cancer Institute.« less

  10. Autologous intravenous bone marrow mononuclear cell therapy for patients with subacute ischaemic stroke: A pilot study

    PubMed Central

    Prasad, Kameshwar; Mohanty, Sujata; Bhatia, Rohit; Srivastava, M.V.P.; Garg, Ajay; Srivastava, Achal; Goyal, Vinay; Tripathi, Manjari; Kumar, Amit; Bal, Chandrashekar; Vij, Aarti; Mishra, Nalini Kant

    2012-01-01

    Background & objectives: Bone marrow mononuclear cell therapy has emerged as one of the option for the treatment of Stroke. Several preclinical studies have shown that the treatment with mononuclear cell (MNCs) can reduce the infarct size and improve the functional outcome. We evaluated the feasibility, safety and clinical outcome of administering bone marrow mononuclear cell (MNCs) intravenously to patients with subacute ischaemic stroke. Methods: In a non-randomized phase-I clinical study, 11 consecutive, eligible and consenting patients, aged 30-70 yr with ischaemic stroke involving anterior circulation within 7 to 30 days of onset of stroke were included. Bone marrow was aspirated from iliac crest and the harvested mononuclear cells were infused into antecubital vein. Outcomes measured for safety included immediate reactions after cell infusion and evidence of tumour formation at one year in whole body PET scan. Patients were followed at week 1, 4-6, 24 and 52 to determine clinical progress using National Institute of Health Stroke Scale (NIHSS), Barthel Index (BI), modified Rankin Scale (mRS), MRI, EEG and PET. Feasibility outcomes included target-dose feasibility. Favourable clinical outcome was defined as mRS score of 2 or less or BI score of 75 to 100 at six months after stem cell therapy. Results: Between September 2006 and April 2007, 11 patients were infused with bone-marrow mononuclear cells (mean 80 million with CD-34+ mean 0.92 million). Protocol was target-dose feasible in 9 patients (82%). FDG-PET scan at 24 and 52 wk in nine patients did not reveal evidence of tumour formation. Seven patients had favourable clinical outcome. Interpretation & conclusions: Intravenous bone marrow mononuclear cell therapy appears feasible and safe in patients with subacute ischaemic stroke. Further, a randomized controlled trial to examine its efficacy is being conducted. PMID:22960888

  11. Melt rheological properties of nucleated PET/MWCNT nanocomposites

    NASA Astrophysics Data System (ADS)

    Gaonkar, Amita; Murudkar, Vrishali; Deshpande, V. D.

    2018-05-01

    This work investigates the effect of precipitated Polyethylene Terephthalate (p-PET) and loading of Multiwalled carbon nanotubes (MWCNT) on morphology and rheology of Polyethylene Terephthalate (PET)/MWCNT nanocomposites. As received PET and Self-Nucleated PET (Nuc-PET) nanocomposites with different loadings of multi-walled carbon nanotubes (MWCNT) were prepared by melt mixing technique. Synthesized reorganized PET crystallizes rapidly from the melt and it is used in small quantities as a self-nucleating agent to make Nuc-PET. In the present study, Rheological properties of nanocomposites are obtained and results show with increase in MWCNT loading complex viscosity of nanocomposites increases. Nonterminal solid like rheological behavior of PET nanocomposites were observed at low frequencies, which indicates the formation of the network like structures of MWCNT in nanocomposites. Morphological and rheological properties of self-nucleated PET nanocomposites improved significantly may be due to self-nucleating agent p-PET. Morphological properties were studied by Scanning Electron Microscopy (SEM). SEM shows better dispersion of MWCNT in Nuc-PET nanocomposites.

  12. The role of Fluorine-18-Fluorodeoxyglucose positron emission tomography in staging and restaging of patients with osteosarcoma

    PubMed Central

    Quartuccio, Natale; Treglia, Giorgio; Salsano, Marco; Mattoli, Maria Vittoria; Muoio, Barbara; Piccardo, Arnoldo; Lopci, Egesta; Cistaro, Angelina

    2013-01-01

    Background The objective of this study is to systematically review the role of positron emission tomography (PET) and PET/computed tomography (PET/CT) with Fluorine-18-Fluorodeoxyglucose (FDG) in patients with osteosarcoma (OS). Methods A comprehensive literature search of published studies through October 10th, 2012 in PubMed/MEDLINE, Embase and Scopus databases regarding whole-body FDG-PET and FDG-PET/CT in patients with OS was performed. Results We identified 13 studies including 289 patients with OS. With regard to the staging and restaging of OS, the diagnostic performance of FDG-PET and PET/CT seem to be high; FDG-PET and PET/CT seem to be superior to bone scintigraphy and conventional imaging methods in detecting bone metastases; conversely, spiral CT seems to be superior to FDG-PET in detecting pulmonary metastases from OS Conclusions Metabolic imaging may provide additional information in the evaluation of OS patients. The combination of FDG-PET or FDG-PET/CT with conventional imaging methods seems to be a valuable tool in the staging and restaging of OS and may have a relevant impact on the treatment planning. PMID:23801904

  13. Comparison of lesion detection and quantitation of tracer uptake between PET from a simultaneously acquiring whole-body PET/MR hybrid scanner and PET from PET/CT.

    PubMed

    Wiesmüller, Marco; Quick, Harald H; Navalpakkam, Bharath; Lell, Michael M; Uder, Michael; Ritt, Philipp; Schmidt, Daniela; Beck, Michael; Kuwert, Torsten; von Gall, Carl C

    2013-01-01

    PET/MR hybrid scanners have recently been introduced, but not yet validated. The aim of this study was to compare the PET components of a PET/CT hybrid system and of a simultaneous whole-body PET/MR hybrid system with regard to reproducibility of lesion detection and quantitation of tracer uptake. A total of 46 patients underwent a whole-body PET/CT scan 1 h after injection and an average of 88 min later a second scan using a hybrid PET/MR system. The radioactive tracers used were (18)F-deoxyglucose (FDG), (18)F-ethylcholine (FEC) and (68)Ga-DOTATATE (Ga-DOTATATE). The PET images from PET/CT (PET(CT)) and from PET/MR (PET(MR)) were analysed for tracer-positive lesions. Regional tracer uptake in these foci was quantified using volumes of interest, and maximal and average standardized uptake values (SUV(max) and SUV(avg), respectively) were calculated. Of the 46 patients, 43 were eligible for comparison and statistical analysis. All lesions except one identified by PET(CT) were identified by PET(MR) (99.2 %). In 38 patients (88.4 %), the same number of foci were identified by PET(CT) and by PET(MR). In four patients, more lesions were identified by PET(MR) than by PET(CT), in one patient PET(CT) revealed an additional focus compared to PET(MR). The mean SUV(max) and SUV(avg) of all lesions determined by PET(MR) were by 21 % and 11 % lower, respectively, than the values determined by PET(CT) (p < 0.05), and a strong correlation between these variables was identified (Spearman rho 0.835; p < 0.01). PET/MR showed equivalent performance in terms of qualitative lesion detection to PET/CT. The differences demonstrated in quantitation of tracer uptake between PET(CT) and PET(MR) were minor, but statistically significant. Nevertheless, a more detailed study of the quantitative accuracy of PET(MR) and the factors governing it is needed to ultimately assess its accuracy in measuring tissue tracer concentrations.

  14. Does pet arrival trigger prosocial behaviors in individuals with autism?

    PubMed

    Grandgeorge, Marine; Tordjman, Sylvie; Lazartigues, Alain; Lemonnier, Eric; Deleau, Michel; Hausberger, Martine

    2012-01-01

    Alteration of social interactions especially prosocial behaviors--an important aspect of development--is one of the characteristics of autistic disorders. Numerous strategies or therapies are used to improve communication skills or at least to reduce social impairments. Animal-assisted therapies are used widely but their relevant benefits have never been scientifically evaluated. In the present study, we evaluated the association between the presence or the arrival of pets in families with an individual with autism and the changes in his or her prosocial behaviors. Of 260 individuals with autism--on the basis of presence or absence of pets--two groups of 12 individuals and two groups of 8 individuals were assigned to: study 1 (pet arrival after age of 5 versus no pet) and study 2 (pet versus no pet), respectively. Evaluation of social impairment was assessed at two time periods using the 36-items ADI-R algorithm and a parental questionnaire about their child-pet relationships. The results showed that 2 of the 36 items changed positively between the age of 4 to 5 (t(0)) and time of assessment (t(1)) in the pet arrival group (study 1): "offering to share" and "offering comfort". Interestingly, these two items reflect prosocial behaviors. There seemed to be no significant changes in any item for the three other groups. The interactions between individuals with autism and their pets were more--qualitatively and quantitatively--reported in the situation of pet arrival than pet presence since birth. These findings open further lines of research on the impact of pet's presence or arrival in families with an individual with autism. Given the potential ability of individuals with autism to develop prosocial behaviors, related studies are needed to better understand the mechanisms involved in the development of such child-pet relationship.

  15. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bhattacharyya, R.; Dey, S.; Ghosh, Sanjay K.

    Various phenomenological models presented over the years have hinted at the possible presence of strangelets, which are nuggets of Strange Quark Matter (SQM), in cosmic rays. One way to search for such rare events is through the deployment of large area Nuclear Track Detector (NTD) arrays at high mountain altitudes. Before the deployment of any such array can begin, a detailed study of the radiation background is essential. Also, a proper understanding of the response of detectors exposed to extreme weather conditions is necessary. With that aim, pilot studies were carried out at various high altitude locations in India suchmore » as Darjeeling (2200 m a.m.s.l), Ooty (2200 m a.m.s.l) and Hanle (4500 m a.m.s.l). Small arrays of CR-39 as well as high threshold Polyethylene Terephthalate (PET) detectors were given open air exposures for periods ranging from three months to two years. The findings of such studies are reported in this paper.« less

  16. Approaches using molecular imaging technology -- use of PET in clinical microdose studies.

    PubMed

    Wagner, Claudia C; Langer, Oliver

    2011-06-19

    Positron emission tomography (PET) imaging uses minute amounts of radiolabeled drug tracers and thereby meets the criteria for clinical microdose studies. The advantage of PET, when compared to other analytical methods used in microdose studies, is that the pharmacokinetics (PK) of a drug can be determined in the tissue targeted for drug treatment. PET microdosing already offers interesting applications in clinical oncology and in the development of central nervous system pharmaceuticals and is extending its range of application to many other fields of pharmaceutical medicine. Although requirements for preclinical safety testing for microdose studies have been cut down by regulatory authorities, radiopharmaceuticals increasingly need to be produced under good manufacturing practice (GMP) conditions, which increases the costs of PET microdosing studies. Further challenges in PET microdosing include combining PET with other ultrasensitive analytical methods, such as accelerator mass spectrometry (AMS), to gain plasma PK data of drugs, beyond the short PET examination periods. Finally, conducting clinical PET studies with radiolabeled drugs both at micro- and therapeutic doses is encouraged to answer the question of dose linearity in clinical microdosing. Copyright © 2010 Elsevier B.V. All rights reserved.

  17. Are emotionally attached companion animal caregivers conscientious and neurotic? Factors that affect the human-companion animal relationship.

    PubMed

    Reevy, Gretchen M; Delgado, Mikel M

    2015-01-01

    Few studies have examined how personality traits may be related to the amounts and types of attachments humans have toward companion animals (pets). In this study, 1,098 companion animal guardians (owners) completed a survey that included the Big Five Inventory, the Lexington Attachment to Pets Scale, and the Pet Attachment Questionnaire. Each participant chose whether he or she identified as a Cat Person, Dog Person, Both, or Neither. Results indicated that neuroticism, conscientiousness, choosing a dog as a favorite pet, and identifying as a Cat Person, Dog Person, or Both predicted affection for a pet. Conscientiousness, extraversion, and openness decreased avoidant attachment to pets, and neuroticism increased anxious attachment to pets. Both dogs and cats could benefit from pet owners who are conscientious, and there may be some benefits of neuroticism in pet owners. The findings of this study will advance understanding of the human-animal bond. As this understanding increases, measurements of human attachment and personality may be useful for the development of tools that could assist shelter employees and veterinarians in counseling people about pet ownership.

  18. Friends with benefits: on the positive consequences of pet ownership.

    PubMed

    McConnell, Allen R; Brown, Christina M; Shoda, Tonya M; Stayton, Laura E; Martin, Colleen E

    2011-12-01

    Social support is critical for psychological and physical well-being, reflecting the centrality of belongingness in our lives. Human interactions often provide people with considerable social support, but can pets also fulfill one's social needs? Although there is correlational evidence that pets may help individuals facing significant life stressors, little is known about the well-being benefits of pets for everyday people. Study 1 found in a community sample that pet owners fared better on several well-being (e.g., greater self-esteem, more exercise) and individual-difference (e.g., greater conscientiousness, less fearful attachment) measures. Study 2 assessed a different community sample and found that owners enjoyed better well-being when their pets fulfilled social needs better, and the support that pets provided complemented rather than competed with human sources. Finally, Study 3 brought pet owners into the laboratory and experimentally demonstrated the ability of pets to stave off negativity caused by social rejection. In summary, pets can serve as important sources of social support, providing many positive psychological and physical benefits for their owners.

  19. Diagnostic accuracy of 18F-FDG-PET and PET/CT in the differential diagnosis between malignant and benign pleural lesions: a systematic review and meta-analysis.

    PubMed

    Treglia, Giorgio; Sadeghi, Ramin; Annunziata, Salvatore; Lococo, Filippo; Cafarotti, Stefano; Bertagna, Francesco; Prior, John O; Ceriani, Luca; Giovanella, Luca

    2014-01-01

    To systematically review and meta-analyze published data about the diagnostic accuracy of fluorine-18-fluorodeoxyglucose ((18)F-FDG) positron emission tomography (PET) and PET/computed tomography (CT) in the differential diagnosis between malignant and benign pleural lesions. A comprehensive literature search of studies published through June 2013 regarding the diagnostic performance of (18)F-FDG-PET and PET/CT in the differential diagnosis of pleural lesions was carried out. All retrieved studies were reviewed and qualitatively analyzed. Pooled sensitivity, specificity, positive and negative likelihood ratio (LR+ and LR-) and diagnostic odds ratio (DOR) of (18)F-FDG-PET or PET/CT in the differential diagnosis of pleural lesions on a per-patient-based analysis were calculated. The area under the summary receiver operating characteristic curve (AUC) was calculated to measure the accuracy of these methods. Subanalyses considering device used (PET or PET/CT) were performed. Sixteen studies including 745 patients were included in the systematic review. The meta-analysis of 11 selected studies provided the following results: sensitivity 95% (95% confidence interval [95%CI]: 92-97%), specificity 82% (95%CI: 76-88%), LR+ 5.3 (95%CI: 2.4-11.8), LR- 0.09 (95%CI: 0.05-0.14), DOR 74 (95%CI: 34-161). The AUC was 0.95. No significant improvement of the diagnostic accuracy considering PET/CT studies only was found. (18)F-FDG-PET and PET/CT demonstrated to be accurate diagnostic imaging methods in the differential diagnosis between malignant and benign pleural lesions; nevertheless, possible sources of false-negative and false-positive results should be kept in mind. Copyright © 2014 AUR. Published by Elsevier Inc. All rights reserved.

  20. Modified physiologically equivalent temperature—basics and applications for western European climate

    NASA Astrophysics Data System (ADS)

    Chen, Yung-Chang; Matzarakis, Andreas

    2018-05-01

    A new thermal index, the modified physiologically equivalent temperature (mPET) has been developed for universal application in different climate zones. The mPET has been improved against the weaknesses of the original physiologically equivalent temperature (PET) by enhancing evaluation of the humidity and clothing variability. The principles of mPET and differences between original PET and mPET are introduced and discussed in this study. Furthermore, this study has also evidenced the usability of mPET with climatic data in Freiburg, which is located in Western Europe. Comparisons of PET, mPET, and Universal Thermal Climate Index (UTCI) have shown that mPET gives a more realistic estimation of human thermal sensation than the other two thermal indices (PET, UTCI) for the thermal conditions in Freiburg. Additionally, a comparison of physiological parameters between mPET model and PET model (Munich Energy Balance Model for Individual, namely MEMI) is proposed. The core temperatures and skin temperatures of PET model vary more violently to a low temperature during cold stress than the mPET model. It can be regarded as that the mPET model gives a more realistic core temperature and mean skin temperature than the PET model. Statistical regression analysis of mPET based on the air temperature, mean radiant temperature, vapor pressure, and wind speed has been carried out. The R square (0.995) has shown a well co-relationship between human biometeorological factors and mPET. The regression coefficient of each factor represents the influence of the each factor on changing mPET (i.e., ±1 °C of T a = ± 0.54 °C of mPET). The first-order regression has been considered predicting a more realistic estimation of mPET at Freiburg during 2003 than the other higher order regression model, because the predicted mPET from the first-order regression has less difference from mPET calculated from measurement data. Statistic tests recognize that mPET can effectively evaluate the influences of all human biometeorological factors on thermal environments. Moreover, a first-order regression function can also predict the thermal evaluations of the mPET by using human biometeorological factors in Freiburg.

  1. Characterization of surface modified polyester fabric.

    PubMed

    Joseph, Roy; Shelma, R; Rajeev, A; Muraleedharan, C V

    2009-12-01

    Woven polyethylene terephthalate (PET) fabric has been used in the construction of vascular grafts and sewing ring of prosthetic heart valves. In an effort to improve haemocompatibility and tissue response to PET fabric, a fluoropolymer, polyvinylidine fluoride (PVDF), was coated on PET fabric by dip coating technique. The coating was found to be uniform and no significant changes occurred on physical properties such as water permeability and burst strength. Cell culture cytotoxicity studies showed that coated PET was non-cytotoxic to L929 fibroblast cell lines. In vitro studies revealed that coating improved haemocompatibility of PET fabric material. Coating reduced platelet consumption of PET fabric by 50%. Upon surface modification leukocyte consumption of PET was reduced by 24%. About 60% reduction in partial thromboplastin time (PTT) observed when PET was coated with PVDF. Results of endothelial cell proliferation studies showed that surface coating did not have any substantial impact on cell proliferation. Overall results indicate that coating has potential to improve haemocompatibility of PET fabric without affecting its mechanical performance.

  2. Pets, Social Participation, and Aging-in-Place: Findings from the Canadian Longitudinal Study on Aging.

    PubMed

    Toohey, Ann M; Hewson, Jennifer A; Adams, Cindy L; Rock, Melanie J

    2018-06-01

    ABSTRACTThe objective of this study was to assess whether pet ownership contributes to social participation and life satisfaction for older adults. We used baseline data from the Canadian Longitudinal Study on Aging (CLSA) for this purpose, and logistic regression models to estimate associations between social participation and life satisfaction for pet owners and non-owners. One third of all older adults (≥ 65 years, n = 7,474) in our sample reported pet ownership. Pet owners were less likely than non-pet owners to report life satisfaction and to participate frequently in social, recreational, or cultural activities, but pet owners were no less satisfied than were non-owners with their current levels of social participation. For pet owners experiencing barriers to social participation, pets appeared protective of life satisfaction in some circumstances. Both individual characteristics and structural factors linked to the World Health Organization's age-friendly communities framework were relevant to understanding these findings.

  3. PET/MRI: Where Might It Replace PET/CT?

    PubMed Central

    Ehman, Eric C.; Johnson, Geoffrey B.; Villanueva-Meyer, Javier E.; Cha, Soonmee; Leynes, Andrew Palmera; Larson, Peder Eric Zufall; Hope, Thomas A.

    2017-01-01

    Simultaneous positron emission tomography and MRI (PET/MRI) is a technology that combines the anatomic and quantitative strengths of MR imaging with physiologic information obtained from PET. PET and computed tomography (PET/ CT) performed in a single scanning session is an established technology already in widespread and accepted use worldwide. Given the higher cost and complexity of operating and interpreting the studies obtained on a PET/MRI system, there has been question as to which patients would benefit most from imaging with PET/MRI versus PET/CT. In this article, we compare PET/MRI with PET/CT, detail the applications for which PET/MRI has shown promise and discuss impediments to future adoption. It is our hope that future work will prove the benefit of PET/MRI to specific groups of patients, initially those in which PET/CT and MRI are already performed, leveraging simultaneity and allowing for greater degrees of multiparametric evaluation. PMID:28370695

  4. Response Assessment in Neuro-Oncology working group and European Association for Neuro-Oncology recommendations for the clinical use of PET imaging in gliomas

    PubMed Central

    Albert, Nathalie L.; Weller, Michael; Suchorska, Bogdana; Galldiks, Norbert; Soffietti, Riccardo; Kim, Michelle M.; la Fougère, Christian; Pope, Whitney; Law, Ian; Arbizu, Javier; Chamberlain, Marc C.; Vogelbaum, Michael; Ellingson, Ben M.

    2016-01-01

    This guideline provides recommendations for the use of PET imaging in gliomas. The review examines established clinical benefit in glioma patients of PET using glucose (18F-FDG) and amino acid tracers (11C-MET, 18F-FET, and 18F-FDOPA). An increasing number of studies have been published on PET imaging in the setting of diagnosis, biopsy, and resection as well radiotherapy planning, treatment monitoring, and response assessment. Recommendations are based on evidence generated from studies which validated PET findings by histology or clinical course. This guideline emphasizes the clinical value of PET imaging with superiority of amino acid PET over glucose PET and provides a framework for the use of PET to assist in the management of patients with gliomas. PMID:27106405

  5. Driving with pets and motor vehicle collision involvement among older drivers: A prospective population-based study.

    PubMed

    Huisingh, Carrie; Levitan, Emily B; Irvin, Marguerite R; Owsley, Cynthia; McGwin, Gerald

    2016-03-01

    Distracted driving is a major cause of motor vehicle collision (MVC) involvement. Pets have been identified as potential distraction to drivers, particularly in the front. This type of distraction could be worse for those with impairment in the cognitive aspects of visual processing. The purpose of this study is to evaluate the association between driving with pets and rates of motor vehicle collision involvement in a cohort of older drivers. A three-year prospective study was conducted in a population-based sample of 2000 licensed drivers aged 70 years and older. At the baseline visit, a trained interviewer asked participants about pet ownership, whether they drive with pets, how frequently, and where the pet sits in the vehicle. Motor vehicle collision (MVC) involvement during the three-year study period was obtained from the Alabama Department of Public Safety. At-fault status was determined by the police officer who arrived on the scene. Participants were followed until the earliest of death, driving cessation, or end of the study period. Poisson regression was used to calculate crude and adjusted rate ratios (RR) examining the association between pet ownership, presence of a pet in a vehicle, frequency of driving with a pet, and location of the pet inside with vehicle with any and at-fault MVC involvement. We examined whether the associations differed by higher order visual processing impairment status, as measured by Useful Field of View, Trails B, and Motor-free Visual Perception Test. Rates of crash involvement were similar for older adults who have ever driven with a pet compared to those who never drove with their pet (RR=1.15, 95% CI 0.76-1.75). Drivers who reported always or sometimes driving with their pet had higher MVC rates compared to pet owners who never drive with a pet, but this association was not statistically significant (RR=1.39, 95% CI 0.86-2.24). In terms of location, those reporting having a pet frequently ride in the front of the vehicle had similar rates of MVC involvement compared to those who did not drive with a pet in the front. A similar pattern of results was observed for at-fault MVCs. This association was not modified by visual processing impairment status. The current study demonstrates a positive but non-significant association between frequently driving with pets and MVC involvement. More research is needed, particularly on restraint use and whether the pet was in the car at the time of the crash, to help characterize the public safety benefit of regulations on driving with pets. Copyright © 2015 Elsevier Ltd. All rights reserved.

  6. Do allergic families avoid keeping furry pets?

    PubMed

    Bertelsen, R J; Carlsen, K C L; Granum, B; Carlsen, K-H; Håland, G; Devulapalli, C S; Munthe-Kaas, M C; Mowinckel, P; Løvik, M

    2010-06-01

    Studies addressing the relationship between pet keeping and development of asthma and allergies may be influenced by pet avoidance in families with a history of allergic disease. Following a cohort of 1019 children in Oslo till 10 years of age, we studied the association of pet keeping with socio-economic factors and allergic disease in the family. A family history of asthma and rhinoconjunctivitis was not significantly associated with pet ownership at birth or with pet removal by 10 years. Acquiring cats and dogs was less likely if the child had allergic rhinoconjunctivitis, whereas no association was seen with asthma (in any family member). Single parenthood increased the likelihood of acquiring a cat, smoking parents more often had cats or dogs, and having older siblings was associated with keeping dogs and other furry pets. Among 319 families reporting pet avoidance, 70% never had pets, 8% had given up pets, and 22% avoided a particular type of pet only. Twenty-four per cent of the parents failed to retrospectively report pet keeping during the child's first year of life. Overall, allergic rhinitis, but not asthma was associated with actual pet avoidance, whereas the strongest predictors for keeping pets were found to be socio-economic factors. Allergic disease in a child most often does not lead to the removal of the family's furry pet. Pet avoidance is associated with allergic symptoms, but not asthma. Socio-economic factors like parental education, single parenthood and smoking affects the families' decisions on pet keeping, including the type of pets the families will avoid or acquire. The large recall error demonstrated points to the need for prospective data regarding pet keeping.

  7. Comparison of PET/CT with Sequential PET/MRI Using an MR-Compatible Mobile PET System.

    PubMed

    Nakamoto, Ryusuke; Nakamoto, Yuji; Ishimori, Takayoshi; Fushimi, Yasutaka; Kido, Aki; Togashi, Kaori

    2018-05-01

    The current study tested a newly developed flexible PET (fxPET) scanner prototype. This fxPET system involves dual arc-shaped detectors based on silicon photomultipliers that are designed to fit existing MRI devices, allowing us to obtain fused PET and MR images by sequential PET and MR scanning. This prospective study sought to evaluate the image quality, lesion detection rate, and quantitative values of fxPET in comparison with conventional whole-body (WB) PET and to assess the accuracy of registration. Methods: Seventeen patients with suspected or known malignant tumors were analyzed. Approximately 1 h after intravenous injection of 18 F-FDG, WB PET/CT was performed, followed by fxPET and MRI. For reconstruction of fxPET images, MRI-based attenuation correction was applied. The quality of fxPET images was visually assessed, and the number of detected lesions was compared between the 2 imaging methods. SUV max and maximum average SUV within a 1 cm 3 spheric volume (SUV peak ) of lesions were also compared. In addition, the magnitude of misregistration between fxPET and MR images was evaluated. Results: The image quality of fxPET was acceptable for diagnosis of malignant tumors. There was no significant difference in detectability of malignant lesions between fxPET and WB PET ( P > 0.05). However, the fxPET system did not exhibit superior performance to the WB PET system. There were strong positive correlations between the 2 imaging modalities in SUV max (ρ = 0.88) and SUV peak (ρ = 0.81). SUV max and SUV peak measured with fxPET were approximately 1.1-fold greater than measured with WB PET. The average misregistration between fxPET and MR images was 5.5 ± 3.4 mm. Conclusion: Our preliminary data indicate that running an fxPET scanner near an existing MRI system provides visually and quantitatively acceptable fused PET/MR images for diagnosis of malignant lesions. © 2018 by the Society of Nuclear Medicine and Molecular Imaging.

  8. Pet ownership and physical health.

    PubMed

    Matchock, Robert L

    2015-09-01

    Pet ownership and brief human-animal interactions can serve as a form of social support and convey a host of beneficial psychological and physiological health benefits. This article critically examines recent relevant literature on the pet-health connection. Cross-sectional studies indicate correlations between pet ownership and numerous aspects of positive health outcomes, including improvements on cardiovascular measures and decreases in loneliness. Quasi-experimental studies and better controlled experimental studies corroborate these associations and suggest that owning and/or interacting with a pet may be causally related to some positive health outcomes. The value of pet ownership and animal-assisted therapy (AAT), as a nonpharmacological treatment modality, augmentation to traditional treatment, and healthy preventive behavior (in the case of pet ownership), is starting to be realized. However, more investigations that employ randomized controlled trials with larger sample sizes and investigations that more closely examine the underlying mechanism of the pet-health effect, such as oxytocin, are needed.

  9. Evidence for the use PET for radiation therapy planning in patients with cervical cancer: a systematic review.

    PubMed

    Salem, A; Salem, A F; Al-Ibraheem, A; Lataifeh, I; Almousa, A; Jaradat, I

    2011-01-01

    In recent years, the role of positron emission tomography (PET) in the staging and management of gynecological cancers has been increasing. The aim of this study was to systematically review the role of PET in radiotherapy planning and brachytherapy treatment optimization in patients with cervical cancer. Systematic literature review. Systematic review of relevant literature addressing the utilization of PET and/or PET-computed tomography (CT) in external-beam radiotherapy planning and brachytherapy treatment optimization. We performed an extensive PubMed database search on 20 April 2011. Nineteen studies, including 759 patients, formed the basis of this systematic review. PET/ PET-CT is the most sensitive imaging modality for detecting nodal metastases in patients with cervical cancer and has been shown to impact external-beam radiotherapy planning by modifying the treatment field and customizing the radiation dose. This particularly applies to detection of previously uncovered para-aortic and inguinal nodal metastases. Furthermore, PET/ PET-CT guided intensity-modulated radiation therapy (IMRT) allows delivery of higher doses of radiation to the primary tumor, if brachytherapy is unsuitable, and to grossly involved nodal disease while minimizing treatment-related toxicity. PET/ PET-CT based brachytherapy optimization allows improved tumor-volume dose distribution and detailed 3D dosimetric evaluation of risk organs. Sequential PET/ PET-CT imaging performed during the course of brachytherapy form the basis of “adaptive” brachytherapy in cervical cancer. This review demonstrates the effectiveness of pretreatment PET/ PET-CT in cervical cancer patients treated by radiotherapy. Further prospective studies are required to define the group of patients who would benefit the most from this procedure.

  10. Automated movement correction for dynamic PET/CT images: evaluation with phantom and patient data.

    PubMed

    Ye, Hu; Wong, Koon-Pong; Wardak, Mirwais; Dahlbom, Magnus; Kepe, Vladimir; Barrio, Jorge R; Nelson, Linda D; Small, Gary W; Huang, Sung-Cheng

    2014-01-01

    Head movement during a dynamic brain PET/CT imaging results in mismatch between CT and dynamic PET images. It can cause artifacts in CT-based attenuation corrected PET images, thus affecting both the qualitative and quantitative aspects of the dynamic PET images and the derived parametric images. In this study, we developed an automated retrospective image-based movement correction (MC) procedure. The MC method first registered the CT image to each dynamic PET frames, then re-reconstructed the PET frames with CT-based attenuation correction, and finally re-aligned all the PET frames to the same position. We evaluated the MC method's performance on the Hoffman phantom and dynamic FDDNP and FDG PET/CT images of patients with neurodegenerative disease or with poor compliance. Dynamic FDDNP PET/CT images (65 min) were obtained from 12 patients and dynamic FDG PET/CT images (60 min) were obtained from 6 patients. Logan analysis with cerebellum as the reference region was used to generate regional distribution volume ratio (DVR) for FDDNP scan before and after MC. For FDG studies, the image derived input function was used to generate parametric image of FDG uptake constant (Ki) before and after MC. Phantom study showed high accuracy of registration between PET and CT and improved PET images after MC. In patient study, head movement was observed in all subjects, especially in late PET frames with an average displacement of 6.92 mm. The z-direction translation (average maximum = 5.32 mm) and x-axis rotation (average maximum = 5.19 degrees) occurred most frequently. Image artifacts were significantly diminished after MC. There were significant differences (P<0.05) in the FDDNP DVR and FDG Ki values in the parietal and temporal regions after MC. In conclusion, MC applied to dynamic brain FDDNP and FDG PET/CT scans could improve the qualitative and quantitative aspects of images of both tracers.

  11. Automated Movement Correction for Dynamic PET/CT Images: Evaluation with Phantom and Patient Data

    PubMed Central

    Ye, Hu; Wong, Koon-Pong; Wardak, Mirwais; Dahlbom, Magnus; Kepe, Vladimir; Barrio, Jorge R.; Nelson, Linda D.; Small, Gary W.; Huang, Sung-Cheng

    2014-01-01

    Head movement during a dynamic brain PET/CT imaging results in mismatch between CT and dynamic PET images. It can cause artifacts in CT-based attenuation corrected PET images, thus affecting both the qualitative and quantitative aspects of the dynamic PET images and the derived parametric images. In this study, we developed an automated retrospective image-based movement correction (MC) procedure. The MC method first registered the CT image to each dynamic PET frames, then re-reconstructed the PET frames with CT-based attenuation correction, and finally re-aligned all the PET frames to the same position. We evaluated the MC method's performance on the Hoffman phantom and dynamic FDDNP and FDG PET/CT images of patients with neurodegenerative disease or with poor compliance. Dynamic FDDNP PET/CT images (65 min) were obtained from 12 patients and dynamic FDG PET/CT images (60 min) were obtained from 6 patients. Logan analysis with cerebellum as the reference region was used to generate regional distribution volume ratio (DVR) for FDDNP scan before and after MC. For FDG studies, the image derived input function was used to generate parametric image of FDG uptake constant (Ki) before and after MC. Phantom study showed high accuracy of registration between PET and CT and improved PET images after MC. In patient study, head movement was observed in all subjects, especially in late PET frames with an average displacement of 6.92 mm. The z-direction translation (average maximum = 5.32 mm) and x-axis rotation (average maximum = 5.19 degrees) occurred most frequently. Image artifacts were significantly diminished after MC. There were significant differences (P<0.05) in the FDDNP DVR and FDG Ki values in the parietal and temporal regions after MC. In conclusion, MC applied to dynamic brain FDDNP and FDG PET/CT scans could improve the qualitative and quantitative aspects of images of both tracers. PMID:25111700

  12. A Systematic Review and Meta-Analysis of the Campylobacter spp. Prevalence and Concentration in Household Pets and Petting Zoo Animals for Use in Exposure Assessments

    PubMed Central

    Pintar, Katarina D. M.; Christidis, Tanya; Thomas, M. Kate; Anderson, Maureen; Nesbitt, Andrea; Keithlin, Jessica; Marshall, Barbara; Pollari, Frank

    2015-01-01

    Animal contact is a potential transmission route for campylobacteriosis, and both domestic household pet and petting zoo exposures have been identified as potential sources of exposure. Research has typically focussed on the prevalence, concentration, and transmission of zoonoses from farm animals to humans, yet there are gaps in our understanding of these factors among animals in contact with the public who don’t live on or visit farms. This study aims to quantify, through a systematic review and meta-analysis, the prevalence and concentration of Campylobacter carriage in household pets and petting zoo animals. Four databases were accessed for the systematic review (PubMed, CAB direct, ProQuest, and Web of Science) for papers published in English from 1992–2012, and studies were included if they examined the animal population of interest, assessed prevalence or concentration with fecal, hair coat, oral, or urine exposure routes (although only articles that examined fecal routes were found), and if the research was based in Canada, USA, Europe, Australia, and New Zealand. Studies were reviewed for qualitative synthesis and meta-analysis by two reviewers, compiled into a database, and relevant studies were used to create a weighted mean prevalence value. There were insufficient data to run a meta-analysis of concentration values, a noted study limitation. The mean prevalence of Campylobacter in petting zoo animals is 6.5% based on 7 studies, and in household pets the mean is 24.7% based on 34 studies. Our estimated concentration values were: 7.65x103cfu/g for petting zoo animals, and 2.9x105cfu/g for household pets. These results indicate that Campylobacter prevalence and concentration are lower in petting zoo animals compared with household pets and that both of these animal sources have a lower prevalence compared with farm animals that do not come into contact with the public. There is a lack of studies on Campylobacter in petting zoos and/or fair animals in Canada and abroad. Within this literature, knowledge gaps were identified, and include: a lack of concentration data reported in the literature for Campylobacter spp. in animal feces, a distinction between ill and diarrheic pets in the reported studies, noted differences in shedding and concentrations for various subtypes of Campylobacter, and consistent reporting between studies. PMID:26683667

  13. A Systematic Review and Meta-Analysis of the Campylobacter spp. Prevalence and Concentration in Household Pets and Petting Zoo Animals for Use in Exposure Assessments.

    PubMed

    Pintar, Katarina D M; Christidis, Tanya; Thomas, M Kate; Anderson, Maureen; Nesbitt, Andrea; Keithlin, Jessica; Marshall, Barbara; Pollari, Frank

    2015-01-01

    Animal contact is a potential transmission route for campylobacteriosis, and both domestic household pet and petting zoo exposures have been identified as potential sources of exposure. Research has typically focussed on the prevalence, concentration, and transmission of zoonoses from farm animals to humans, yet there are gaps in our understanding of these factors among animals in contact with the public who don't live on or visit farms. This study aims to quantify, through a systematic review and meta-analysis, the prevalence and concentration of Campylobacter carriage in household pets and petting zoo animals. Four databases were accessed for the systematic review (PubMed, CAB direct, ProQuest, and Web of Science) for papers published in English from 1992-2012, and studies were included if they examined the animal population of interest, assessed prevalence or concentration with fecal, hair coat, oral, or urine exposure routes (although only articles that examined fecal routes were found), and if the research was based in Canada, USA, Europe, Australia, and New Zealand. Studies were reviewed for qualitative synthesis and meta-analysis by two reviewers, compiled into a database, and relevant studies were used to create a weighted mean prevalence value. There were insufficient data to run a meta-analysis of concentration values, a noted study limitation. The mean prevalence of Campylobacter in petting zoo animals is 6.5% based on 7 studies, and in household pets the mean is 24.7% based on 34 studies. Our estimated concentration values were: 7.65x103cfu/g for petting zoo animals, and 2.9x105cfu/g for household pets. These results indicate that Campylobacter prevalence and concentration are lower in petting zoo animals compared with household pets and that both of these animal sources have a lower prevalence compared with farm animals that do not come into contact with the public. There is a lack of studies on Campylobacter in petting zoos and/or fair animals in Canada and abroad. Within this literature, knowledge gaps were identified, and include: a lack of concentration data reported in the literature for Campylobacter spp. in animal feces, a distinction between ill and diarrheic pets in the reported studies, noted differences in shedding and concentrations for various subtypes of Campylobacter, and consistent reporting between studies.

  14. Studies of the brain cannabinoid system using positron emission tomography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gatley, S.J.; Volkow, N.D.

    Studies using radiolabeled psychoactive drugs in conjunction with positron emission tomography (PET) have permitted the imaging of binding sites in the human brain. Similar studies of marijuana have been hampered by the unsuitability of radiolabeled THC for PET studies, and the current unavailability of other in vivo imaging agents for cannabinoid receptors. Recent developments in medicinal chemistry suggest that a PET radiotracer for cannabinoid receptors will soon become available. This chapter briefly reviews these developments, together with the results of PET studies of the effects of marijuana and other abused drugs on brain metabolism. It also reviews PET studies ofmore » cocaine binding sites, to demonstrate the kind of investigations that will be possible when a cannabinoid receptor PET radioligand becomes available.« less

  15. Diagnostic performance of fluorine-18-fluorodeoxyglucose positron emission tomography in the assessment of pleural abnormalities in cancer patients: a systematic review and a meta-analysis.

    PubMed

    Treglia, Giorgio; Sadeghi, Ramin; Annunziata, Salvatore; Lococo, Filippo; Cafarotti, Stefano; Prior, John O; Bertagna, Francesco; Ceriani, Luca; Giovanella, Luca

    2014-01-01

    To systematically review and meta-analyze published data about the diagnostic performance of Fluorine-18-Fluorodeoxyglucose ((18)F-FDG) positron emission tomography (PET) and PET/computed tomography (PET/CT) in the assessment of pleural abnormalities in cancer patients. A comprehensive literature search of studies published through June 2013 regarding the role of (18)F-FDG-PET and PET/CT in evaluating pleural abnormalities in cancer patients was performed. All retrieved studies were reviewed and qualitatively analyzed. Pooled sensitivity, specificity, positive and negative likelihood ratio (LR+ and LR-) and diagnostic odd ratio (DOR) of (18)F-FDG-PET or PET/CT on a per patient-based analysis were calculated. The area under the summary ROC curve (AUC) was calculated to measure the accuracy of these methods in the assessment of pleural abnormalities. Sub-analyses considering (18)F-FDG-PET/CT and patients with lung cancer only were carried out. Eight studies comprising 360 cancer patients (323 with lung cancer) were included. The meta-analysis of these selected studies provided the following results: sensitivity 86% [95% confidence interval (95%CI): 80-91%], specificity 80% [95%CI: 73-85%], LR+ 3.7 [95%CI: 2.8-4.9], LR- 0.18 [95%CI: 0.09-0.34], DOR 27 [95%CI: 13-56]. The AUC was 0.907. No significant improvement considering PET/CT studies only and patients with lung cancer was found. (18)F-FDG-PET and PET/CT demonstrated to be useful diagnostic imaging methods in the assessment of pleural abnormalities in cancer patients, nevertheless possible sources of false-negative and false-positive results should be kept in mind. The literature focusing on the use of (18)F-FDG-PET and PET/CT in this setting remains still limited and prospective studies are needed. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  16. Towards tracer dose reduction in PET studies: Simulation of dose reduction by retrospective randomized undersampling of list-mode data.

    PubMed

    Gatidis, Sergios; Würslin, Christian; Seith, Ferdinand; Schäfer, Jürgen F; la Fougère, Christian; Nikolaou, Konstantin; Schwenzer, Nina F; Schmidt, Holger

    2016-01-01

    Optimization of tracer dose regimes in positron emission tomography (PET) imaging is a trade-off between diagnostic image quality and radiation exposure. The challenge lies in defining minimal tracer doses that still result in sufficient diagnostic image quality. In order to find such minimal doses, it would be useful to simulate tracer dose reduction as this would enable to study the effects of tracer dose reduction on image quality in single patients without repeated injections of different amounts of tracer. The aim of our study was to introduce and validate a method for simulation of low-dose PET images enabling direct comparison of different tracer doses in single patients and under constant influencing factors. (18)F-fluoride PET data were acquired on a combined PET/magnetic resonance imaging (MRI) scanner. PET data were stored together with the temporal information of the occurrence of single events (list-mode format). A predefined proportion of PET events were then randomly deleted resulting in undersampled PET data. These data sets were subsequently reconstructed resulting in simulated low-dose PET images (retrospective undersampling of list-mode data). This approach was validated in phantom experiments by visual inspection and by comparison of PET quality metrics contrast recovery coefficient (CRC), background-variability (BV) and signal-to-noise ratio (SNR) of measured and simulated PET images for different activity concentrations. In addition, reduced-dose PET images of a clinical (18)F-FDG PET dataset were simulated using the proposed approach. (18)F-PET image quality degraded with decreasing activity concentrations with comparable visual image characteristics in measured and in corresponding simulated PET images. This result was confirmed by quantification of image quality metrics. CRC, SNR and BV showed concordant behavior with decreasing activity concentrations for measured and for corresponding simulated PET images. Simulation of dose-reduced datasets based on clinical (18)F-FDG PET data demonstrated the clinical applicability of the proposed data. Simulation of PET tracer dose reduction is possible with retrospective undersampling of list-mode data. Resulting simulated low-dose images have equivalent characteristics with PET images actually measured at lower doses and can be used to derive optimal tracer dose regimes.

  17. Sensory analysis of pet foods.

    PubMed

    Koppel, Kadri

    2014-08-01

    Pet food palatability depends first and foremost on the pet and is related to the pet food sensory properties such as aroma, texture and flavor. Sensory analysis of pet foods may be conducted by humans via descriptive or hedonic analysis, pets via acceptance or preference tests, and through a number of instrumental analysis methods. Sensory analysis of pet foods provides additional information on reasons behind palatable and unpalatable foods as pets lack linguistic capabilities. Furthermore, sensory analysis may be combined with other types of information such as personality and environment factors to increase understanding of acceptable pet foods. Most pet food flavor research is proprietary and, thus, there are a limited number of publications available. Funding opportunities for pet food studies would increase research and publications and this would help raise public awareness of pet food related issues. This mini-review addresses current pet food sensory analysis literature and discusses future challenges and possibilities. © 2014 Society of Chemical Industry.

  18. The Spillover Effect of a Flood on Pets and Their People: Implications for Rental Housing.

    PubMed

    Graham, Taryn M; Rock, Melanie J

    2018-06-04

    When disasters strike, companion animals (pets) matter. Emergency planning for them is a key aspect of disaster preparedness, especially considering that people may delay evacuation out of concern for their pets. Temporary boarding options for pets are important; however, caregivers (owners) must ultimately return to permanent housing. Surprisingly little attention has been paid to housing recovery in the disaster literature on pet ownership, and no studies have examined the potential for increased vulnerability among tenants with pets. This study analyzed online rental listings in a city that was severely flooded in 2013. In the following year, demand for pet-friendly rental housing outweighed supply. Landlords frequently stipulated restrictions on the allowable sizes, species, or breeds of pets. Dogs were often banned outright. To keep their pets, prospective tenants needed to exercise flexibility in location and pay higher surcharges. The implications of housing insecurity for tenants with pets have broad relevance, not just in disaster circumstances. Giving up a companion animal to secure housing can negatively impact resilience, whereas living in unsafe environments to avoid pet relinquishment may increase vulnerability.

  19. 18F-FDG PET/CT in Detecting Metastatic Infection in Children.

    PubMed

    Kouijzer, Ilse J E; Blokhuis, Gijsbert J; Draaisma, Jos M T; Oyen, Wim J G; de Geus-Oei, Lioe-Fee; Bleeker-Rovers, Chantal P

    2016-04-01

    Metastatic infection is a severe complication of bacteremia with high morbidity and mortality. The aim of this study was to investigate the diagnostic value of 18F-FDG PET combined with CT (FDG PET/CT) in children suspected of having metastatic infection. The results of FDG PET/CT scans performed in children because of suspected metastatic infection from September 2003 to June 2013 were analyzed retrospectively. The results were compared with the final clinical diagnosis. FDG PET/CT was performed in 13 children with suspected metastatic infection. Of the total number of FDG PET/CT scans, 38% were clinically helpful. Positive predictive value of FDG PET/CT was 71%, and negative predictive value was 100%. FDG PET/CT appears to be a valuable diagnostic technique in children with suspected metastatic infection. Prospective studies of FDG PET/CT as part of a structured diagnostic protocol are needed to assess the exact additional diagnostic value.

  20. An update on technical and methodological aspects for cardiac PET applications.

    PubMed

    Presotto, Luca; Busnardo, Elena; Gianolli, Luigi; Bettinardi, Valentino

    2016-12-01

    Positron emission tomography (PET) is indicated for a large number of cardiac diseases: perfusion and viability studies are commonly used to evaluate coronary artery disease; PET can also be used to assess sarcoidosis and endocarditis, as well as to investigate amyloidosis. Furthermore, a hot topic for research is plaque characterization. Most of these studies are technically very challenging. High count rates and short acquisition times characterize perfusion scans while very small targets have to be imaged in inflammation/infection and plaques examinations. Furthermore, cardiac PET suffers from respiratory and cardiac motion blur. Each type of studies has specific requirements from the technical and methodological point of view, thus PET systems with overall high performances are required. Furthermore, in the era of hybrid PET/computed tomography (CT) and PET/Magnetic Resonance Imaging (MRI) systems, the combination of complementary functional and anatomical information can be used to improve diagnosis and prognosis. Moreover, PET images can be qualitatively and quantitatively improved exploiting information from the other modality, using advanced algorithms. In this review we will report the latest technological and methodological innovations for PET cardiac applications, with particular reference to the state of the art of the hybrid PET/CT and PET/MRI. We will also report the most recent advancements in software, from reconstruction algorithms to image processing and analysis programs.

  1. 18F-FDG PET/CT and PET/MRI Perform Equally Well in Cancer: Evidence from Studies on More Than 2,300 Patients

    PubMed Central

    Spick, Claudio; Herrmann, Ken; Czernin, Johannes

    2016-01-01

    18F-FDG PET/CT has become the reference standard in oncologic imaging against which the performance of other imaging modalities is measured. The promise of PET/MRI includes multiparametric imaging to further improve diagnosis and phenotyping of cancer. Rather than focusing on these capabilities, many investigators have examined whether 18F-FDG PET combined with mostly anatomic MRI improves cancer staging and restaging. After a description of PET/MRI scanner designs and a discussion of technical and operational issues, we review the available literature to determine whether cancer assessments are improved with PET/MRI. The available data show that PET/MRI is feasible and performs as well as PET/CT in most types of cancer. Diagnostic advantages may be achievable in prostate cancer and in bone metastases, whereas disadvantages exist in lung nodule assessments. We conclude that 18F-FDG PET/MRI and PET/CT provide comparable diagnostic information when MRI is used simply to provide the anatomic framework. Thus, PET/MRI could be used in lieu of PET/CT if this approach becomes economically viable and if reasonable workflows can be established. Future studies should explore the multiparametric potential of MRI. PMID:26742709

  2. Prospective study of functional bone marrow-sparing intensity modulated radiation therapy with concurrent chemotherapy for pelvic malignancies.

    PubMed

    Liang, Yun; Bydder, Mark; Yashar, Catheryn M; Rose, Brent S; Cornell, Mariel; Hoh, Carl K; Lawson, Joshua D; Einck, John; Saenz, Cheryl; Fanta, Paul; Mundt, Arno J; Bydder, Graeme M; Mell, Loren K

    2013-02-01

    To test the hypothesis that intensity modulated radiation therapy (IMRT) can reduce radiation dose to functional bone marrow (BM) in patients with pelvic malignancies (phase IA) and estimate the clinical feasibility and acute toxicity associated with this technique (phase IB). We enrolled 31 subjects (19 with gynecologic cancer and 12 with anal cancer) in an institutional review board-approved prospective trial (6 in the pilot study, 10 in phase IA, and 15 in phase IB). The mean age was 52 years; 8 of 31 patients (26%) were men. Twenty-one subjects completed (18)F-fluorodeoxyglucose (FDG)-positron emission tomography (PET)/computed tomography (CT) simulation and magnetic resonance imaging by use of quantitative IDEAL (IDEAL IQ; GE Healthcare, Waukesha, WI). The PET/CT and IDEAL IQ were registered, and BM subvolumes were segmented above the mean standardized uptake value and below the mean fat fraction within the pelvis and lumbar spine; their intersection was designated as functional BM for IMRT planning. Functional BM-sparing vs total BM-sparing IMRT plans were compared in 12 subjects; 10 were treated with functional BM-sparing pelvic IMRT per protocol. In gynecologic cancer patients, the mean functional BM V(10) (volume receiving ≥10 Gy) and V(20) (volume receiving ≥20 Gy) were 85% vs 94% (P<.0001) and 70% vs 82% (P<.0001), respectively, for functional BM-sparing IMRT vs total BM-sparing IMRT. In anal cancer patients, the corresponding values were 75% vs 77% (P=.06) and 62% vs 67% (P=.002), respectively. Of 10 subjects treated with functional BM-sparing pelvic IMRT, 3 (30%) had acute grade 3 hematologic toxicity or greater. IMRT can reduce dose to BM subregions identified by (18)F-fluorodeoxyglucose-PET/CT and IDEAL IQ. The efficacy of BM-sparing IMRT is being tested in a phase II trial. Copyright © 2013 Elsevier Inc. All rights reserved.

  3. Prospective Study of Functional Bone Marrow-Sparing Intensity Modulated Radiation Therapy With Concurrent Chemotherapy for Pelvic Malignancies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liang Yun; Center for Advanced Radiotherapy Technologies, University of California, San Diego, La Jolla, California; Bydder, Mark

    2013-02-01

    Purpose: To test the hypothesis that intensity modulated radiation therapy (IMRT) can reduce radiation dose to functional bone marrow (BM) in patients with pelvic malignancies (phase IA) and estimate the clinical feasibility and acute toxicity associated with this technique (phase IB). Methods and Materials: We enrolled 31 subjects (19 with gynecologic cancer and 12 with anal cancer) in an institutional review board-approved prospective trial (6 in the pilot study, 10 in phase IA, and 15 in phase IB). The mean age was 52 years; 8 of 31 patients (26%) were men. Twenty-one subjects completed {sup 18}F-fluorodeoxyglucose (FDG)-positron emission tomography (PET)/computedmore » tomography (CT) simulation and magnetic resonance imaging by use of quantitative IDEAL (IDEAL IQ; GE Healthcare, Waukesha, WI). The PET/CT and IDEAL IQ were registered, and BM subvolumes were segmented above the mean standardized uptake value and below the mean fat fraction within the pelvis and lumbar spine; their intersection was designated as functional BM for IMRT planning. Functional BM-sparing vs total BM-sparing IMRT plans were compared in 12 subjects; 10 were treated with functional BM-sparing pelvic IMRT per protocol. Results: In gynecologic cancer patients, the mean functional BM V{sub 10} (volume receiving {>=}10 Gy) and V{sub 20} (volume receiving {>=}20 Gy) were 85% vs 94% (P<.0001) and 70% vs 82% (P<.0001), respectively, for functional BM-sparing IMRT vs total BM-sparing IMRT. In anal cancer patients, the corresponding values were 75% vs 77% (P=.06) and 62% vs 67% (P=.002), respectively. Of 10 subjects treated with functional BM-sparing pelvic IMRT, 3 (30%) had acute grade 3 hematologic toxicity or greater. Conclusions: IMRT can reduce dose to BM subregions identified by {sup 18}F-fluorodeoxyglucose-PET/CT and IDEAL IQ. The efficacy of BM-sparing IMRT is being tested in a phase II trial.« less

  4. Accuracy of fluorodeoxyglucose-PET imaging for differentiating benign from malignant pleural effusions: a meta-analysis.

    PubMed

    Porcel, José M; Hernández, Paula; Martínez-Alonso, Montserrat; Bielsa, Silvia; Salud, Antonieta

    2015-02-01

    The role of fluorodeoxyglucose (FDG)-PET imaging for diagnosing malignant pleural effusions is not well defined. The aim of this study was to summarize the evidence for its use in ruling in or out the malignant origin of a pleural effusion or thickening. A meta-analysis was conducted of diagnostic accuracy studies published in the Cochrane Library, PubMed, and Embase (inception to June 2013) without language restrictions. Two investigators selected studies that had evaluated the performance of FDG-PET imaging in patients with pleural effusions or thickening, using pleural cytopathology or histopathology as the reference standard for malignancy. Subgroup analyses were conducted according to FDG-PET imaging interpretation (qualitative or semiquantitative), PET imaging equipment (PET vs integrated PET-CT imaging), and/or target population (known lung cancer or malignant pleural mesothelioma). Study quality was assessed using Quality Assessment of Diagnostic Accuracy Studies-2. We used a bivariate random-effects model for the analysis and pooling of diagnostic performance measures across studies. Fourteen non-high risk of bias studies, comprising 407 patients with malignant and 232 with benign pleural conditions, met the inclusion criteria. Semiquantitative PET imaging readings had a significantly lower sensitivity for diagnosing malignant effusions than visual assessments (82% vs 91%; P = .026). The pooled test characteristics of integrated PET-CT imaging systems using semiquantitative interpretations for identifying malignant effusions were: sensitivity, 81%; specificity, 74%; positive likelihood ratio (LR), 3.22; negative LR, 0.26; and area under the curve, 0.838. Resultant data were heterogeneous, and spectrum bias should be considered when appraising FDG-PET imaging operating characteristics. The moderate accuracy of PET-CT imaging using semiquantitative readings precludes its routine recommendation for discriminating malignant from benign pleural effusions.

  5. Report on the development and application of PET/CT in mainland China.

    PubMed

    Chen, Yumei; Chen, Ruohua; Zhou, Xiang; Liu, Jianjun; Huang, Gang

    2017-09-08

    To examine the development and application of systems combining positron emission and x-ray-computed tomography systems (PET/CTs) in mainland China. Using a questionnaire, we surveyed Chinese medical institutions on a variety topics relating to their PET/CT systems and its use. The respondents had PET/CTs installed and in clinical use before 31 December 2015. We examined the clinical scenarios to which Chinese PET/CTs were applied by reviewing the related Chinese and international literature from the start of 1995 to the end of 2013; these papers were found by searching the Wanfang and PubMed databases, respectively. The data were then classified and analyzed statistically. At the end of 2015, there were 240 PET/CTs and 101 medical cyclotrons in mainland China. The total number of PET studies performed in 2015 was 469,364. The main clinical applications of PET were found to be diagnostic fludeoxyglucose ( 18 F-FDG) imaging and oncological imaging. A minority of PET/CT studies were performed using 11 C-choline and other imaging agents. The number of papers relating to clinical use of PET/CT in mainland China increased each year over the period of study, in both the Chinese and international literature. Despite this progress, important problems were also apparent, including unbalanced regional development and the limited quality of the research. This study provides detailed information for understanding the development PET/CT technology in mainland China, along with its geographical distribution and clinical application. It may thus prove a useful reference for all those involved in planning the future of PET/CT in China.

  6. Basic study of entire whole-body PET scanners based on the OpenPET geometry

    NASA Astrophysics Data System (ADS)

    Yoshida, Eiji; Yamaya, Taiga; Nishikido, Fumihiko; Inadama, Naoko; Murayama, Hideo

    2010-09-01

    A conventional PET scanner has a 15-25 cm axial field-of-view (FOV) and images a whole body using about six bed positions. An OpenPET geometry can extend the axial FOV with a limited number of detectors. The entire whole-body PET scanner must be able to process a large amount of data effectively. In this work, we study feasibility of the fully 3D entire whole-body PET scanner using the GATE simulation. The OpenPET has 12 block detector rings with the ring diameter of 840 mm and each block detector ring consists of 48 depth-of-interaction (DOI) detectors. The OpenPET has the axial length of 895.95 mm with five parts of 58.95 mm open gaps. The OpenPET has higher single data loss than a conventional PET scanner at grouping circuits. NECR of the OpenPET decreases by single data loss. But single data loss is mitigated by separating the axially arranged detector into two parts. Also, multiple coincidences are found to be important for the entire whole-body PET scanner. The entire whole-body PET scanner with the OpenPET geometry promises to provide a large axial FOV with the open space and to have sufficient performance values. But single data loss at the grouping circuits and multiple coincidences are limited to the peak noise equivalent count rate (NECR) for the entire whole-body PET scanner.

  7. Coercive control and abused women's decisions about their pets when seeking shelter.

    PubMed

    Hardesty, Jennifer L; Khaw, Lyndal; Ridgway, Marcella D; Weber, Cheryl; Miles, Teresa

    2013-09-01

    The importance of pets in families, especially during major life stressors, is well documented. Research suggests links between pet ownership and intimate partner violence (IPV). This study explored abused women's decisions about pets when seeking help from a shelter. Interviews were conducted with 19 women who were pet owners. Using grounded theory methods, two patterns emerged surrounding abusers' treatment of pets, bonds to pets, women's decisions about pets upon seeking shelter, and future plans for pets. The presence of coercive control was central to these patterns. Women also discussed their experiences with and needs from shelter professionals and veterinarians with implications for practice.

  8. Another breed of "service" animals: STARS study findings about pet ownership and recovery from serious mental illness.

    PubMed

    Wisdom, Jennifer P; Saedi, Goal Auzeen; Green, Carla A

    2009-07-01

    This study elucidates the role of pets in recovery processes among adults with serious mental illness. Data derive from interviews with 177 HMO members with serious mental illness (52.2% women, average age 48.8 years) in the Study of Transitions and Recovery Strategies (STARS). Interviews and questionnaires addressed factors affecting recovery processes and included questions about pet ownership. Data were analyzed using a modified grounded theory method to identify the roles pets play in the recovery process. Primary themes indicate pets assist individuals in recovery from serious mental illness by (a) providing empathy and "therapy"; (b) providing connections that can assist in redeveloping social avenues; (c) serving as "family" in the absence of or in addition to human family members; and (d) supporting self-efficacy and strengthening a sense of empowerment. Pets appear to provide more benefits than merely companionship. Participants' reports of pet-related contributions to their well-being provide impetus to conduct more formal research on the mechanisms by which pets contribute to recovery and to develop pet-based interventions.

  9. PET studies in epilepsy

    PubMed Central

    Sarikaya, Ismet

    2015-01-01

    Various PET studies, such as measurements of glucose, serotonin and oxygen metabolism, cerebral blood flow and receptor bindings are availabe for epilepsy. 18Fluoro-2-deoxyglucose (18F-FDG) PET imaging of brain glucose metabolism is a well established and widely available technique. Studies have demonstrated that the sensitivity of interictal FDG-PET is higher than interictal SPECT and similar to ictal SPECT for the lateralization and localization of epileptogenic foci in presurgical patients refractory to medical treatments who have noncontributory EEG and MRI. In addition to localizing epileptogenic focus, FDG-PET provide additional important information on the functional status of the rest of the brain. The main limitation of interictal FDG-PET is that it cannot precisely define the surgical margin as the area of hypometabolism usually extends beyond the epileptogenic zone. Various neurotransmitters (GABA, glutamate, opiates, serotonin, dopamine, acethylcholine, and adenosine) and receptor subtypes are involved in epilepsy. PET receptor imaging studies performed in limited centers help to understand the role of neurotransmitters in epileptogenesis, identify epileptic foci and investigate new treatment approaches. PET receptor imaging studies have demonstrated reduced 11C-flumazenil (GABAA-cBDZ) and 18F-MPPF (5-HT1A serotonin) and increased 11C-cerfentanil (mu opiate) and 11C-MeNTI (delta opiate) bindings in the area of seizure. 11C-flumazenil has been reported to be more sensitive than FDG-PET for identifying epileptic foci. The area of abnormality on GABAAcBDZ and opiate receptor images is usually smaller and more circumscribed than the area of hypometabolism on FDG images. Studies have demonstrated that 11C-alpha-methyl-L-tryptophan PET (to study synthesis of serotonin) can detect the epileptic focus within malformations of cortical development and helps in differentiating epileptogenic from non-epileptogenic tubers in patients with tuberous sclerosis complex. 15O-H2O PET was reported to have a similar sensitivity to FDG-PET in detecting epileptic foci. PMID:26550535

  10. Breath-hold [68Ga]DOTA-TOC PET/CT in neuroendocrine tumors: detection of additional lesions and effects on quantitative parameters.

    PubMed

    Zirnsak, Mariana; Bärwolf, Robert; Freesmeyer, Martin

    2016-11-08

    Respiratory motion during PET/CT acquisition generates artifacts in the form of breath-related blurring, which influences the lesion detectability and diagnostic accuracy. The goal of this study was to verify whether breath-hold [68Ga]DOTA-TOC PET/CT (bhPET) allows detection of additional foci compared to free-breathing PET/CT (fbPET), and to assess the impact of breath-holding on standard uptake values (SUV) and isocontoured volume (Vic40) in patients with neuroendocrine tumors (NET). Patients with NET (n=39) were included in this study. BhPET and fbPET characteristics of 96 lesions were compared, and correlated with standard contrast-enhanced (ce) CT and MRI for lesion verification. Quantitative parameters SUV (max and mean) and Vic40 were assessed for both methods and evaluated by linear regression and Spearman's correlation. The impact of lesion size, localization and time interval between investigations was also analyzed. bhPET identified one additional metastasis not seen at fbPET but visible at ceMRI. Another additional bhPET focus did not have a morphological correlate. At bhPET, the SUVmax and SUVmean proved significantly higher and the Vic40 significantly lower than at fbPET. Lesion size, localization and time intervals did not impact significantly on SUV or Vic40. Currently, routine use of breath-hold [68Ga]DOTA-TOC PET/CT cannot be recommended as only one additional lesion was identified. Therefore, bhPET has currently no indication in patients with NET. If technical improvements regarding PET/CT scanner sensitivity are available, bhPET should be reevaluated in the future.

  11. Feasibility of simultaneous PET/MR of the carotid artery: first clinical experience and comparison to PET/CT

    PubMed Central

    Ripa, Rasmus S; Knudsen, Andreas; Hag, Anne Mette F; Lebech, Anne-Mette; Loft, Annika; Keller, Sune H; Hansen, Adam E; von Benzon, Eric; Højgaard, Liselotte; Kjær, Andreas

    2013-01-01

    The study aimed at comparing PET/MR to PET/CT for imaging the carotid arteries in patients with known increased risk of atherosclerosis. Six HIV-positive men underwent sequential PET/MR and PET/CT of the carotid arteries after injection of 400 MBq of 18F-FDG. PET/MR was performed a median of 131 min after injection. Subsequently,PET/CT was performed. Regions of interest (ROI) were drawn slice by slice to include the carotid arteries and standardized uptake values (SUV) were calculated from both datasets independently. Quantitative comparison of 18F-FDG uptake revealed a high congruence between PET data acquired using the PET/MR system compared to the PET/CT system. The mean difference for SUVmean was -0.18 (p < 0.001) and -0.14 for SUVmax (p < 0.001) indicating a small but significant bias towards lower values using the PET/MR system. The 95% limits of agreement were -0.55 to 0.20 for SUVmean and -0.93 to 0.65 for SUVmax. The image quality of the PET/MR allowed for delineation of the carotid vessel wall. The correlations between 18F-FDG uptake from ROI including both vessel wall and vessel lumen to ROI including only the wall were strong (r = 0.98 for SUVmean and r = 1.00 for SUVmax) indicating that the luminal 18F-FDG content had minimal influence on the values. The study shows for the first time that simultaneous PET/MR of the carotid arteries is feasible in patients with increased risk of atherosclerosis. Quantification of 18F-FDG uptake correlated well between PET/MR and PET/CT despite difference in method of PET attenuation correction, reconstruction algorithm, and detector technology. PMID:23900769

  12. Useful diagnostic biometabolic data obtained by PET/CT and MR fusion imaging using open source software.

    PubMed

    Antonica, Filippo; Asabella, Artor Niccoli; Ferrari, Cristina; Rubini, Domenico; Notaristefano, Antonio; Nicoletti, Adriano; Altini, Corinna; Merenda, Nunzio; Mossa, Emilio; Guarini, Attilio; Rubini, Giuseppe

    2014-01-01

    In the last decade numerous attempts were considered to co-register and integrate different imaging data. Like PET/CT the integration of PET to MR showed great interest. PET/MR scanners are recently tested on different distrectual or systemic pathologies. Unfortunately PET/MR scanners are expensive and diagnostic protocols are still under studies and investigations. Nuclear Medicine imaging highlights functional and biometabolic information but has poor anatomic details. The aim of this study is to integrate MR and PET data to produce distrectual or whole body fused images acquired from different scanners even in different days. We propose an offline method to fuse PET with MR data using an open-source software that has to be inexpensive, reproducible and capable to exchange data over the network. We also evaluate global quality, alignment quality, and diagnostic confidence of fused PET-MR images. We selected PET/CT studies performed in our Nuclear Medicine unit, MR studies provided by patients on DICOM CD media or network received. We used Osirix 5.7 open source version. We aligned CT slices with the first MR slice, pointed and marked for co-registration using MR-T1 sequence and CT as reference and fused with PET to produce a PET-MR image. A total of 100 PET/CT studies were fused with the following MR studies: 20 head, 15 thorax, 24 abdomen, 31 pelvis, 10 whole body. An interval of no more than 15 days between PET and MR was the inclusion criteria. PET/CT, MR and fused studies were evaluated by two experienced radiologist and two experienced nuclear medicine physicians. Each one filled a five point based evaluation scoring scheme based on image quality, image artifacts, segmentation errors, fusion misalignment and diagnostic confidence. Our fusion method showed best results for head, thorax and pelvic districts in terms of global quality, alignment quality and diagnostic confidence,while for the abdomen and pelvis alignement quality and global quality resulted poor due to internal organs filling variation and time shifting beetwen examinations. PET/CT images with time of flight reconstruction and real attenuation correction were combined with anatomical detailed MRI images. We used Osirix, an image processing Open Source Software dedicated to DICOM images. No additional costs, to buy and upgrade proprietary software are required for combining data. No high technology or very expensive PET/MR scanner, that requires dedicated shielded room spaces and personnel to be employed or to be trained, are needed. Our method allows to share patient PET/MR fused data with different medical staff using dedicated networks. The proposed method may be applied to every MR sequence (MR-DWI and MR-STIR, magnet enhanced sequences) to characterize soft tissue alterations and improve discrimination diseases. It can be applied not only to PET with MR but virtually to every DICOM study.

  13. Simultaneous acquisition of multislice PET and MR images: initial results with a MR-compatible PET scanner.

    PubMed

    Catana, Ciprian; Wu, Yibao; Judenhofer, Martin S; Qi, Jinyi; Pichler, Bernd J; Cherry, Simon R

    2006-12-01

    PET and MRI are powerful imaging techniques that are largely complementary in the information they provide. We have designed and built a MR-compatible PET scanner based on avalanche photodiode technology that allows simultaneous acquisition of PET and MR images in small animals. The PET scanner insert uses magnetic field-insensitive, position-sensitive avalanche photodiode (PSAPD) detectors coupled, via short lengths of optical fibers, to arrays of lutetium oxyorthosilicate (LSO) scintillator crystals. The optical fibers are used to minimize electromagnetic interference between the radiofrequency and gradient coils and the PET detector system. The PET detector module components and the complete PET insert assembly are described. PET data were acquired with and without MR sequences running, and detector flood histograms were compared with the ones generated from the data acquired outside the magnet. A uniform MR phantom was also imaged to assess the effect of the PET detector on the MR data acquisition. Simultaneous PET and MRI studies of a mouse were performed ex vivo. PSAPDs can be successfully used to read out large numbers of scintillator crystals coupled through optical fibers with acceptable performance in terms of energy and timing resolution and crystal identification. The PSAPD-LSO detector performs well in the 7-T magnet, and no visible artifacts are detected in the MR images using standard pulse sequences. The first images from the complete system have been successfully acquired and reconstructed, demonstrating that simultaneous PET and MRI studies are feasible and opening up interesting possibilities for dual-modality molecular imaging studies.

  14. Rheological Properties and Foaming Behavior of Poly(Ethylene Terephthalates) Modified with Pyromellitic Dianhydride

    NASA Astrophysics Data System (ADS)

    Yang, Zhao-Ping; Xin, Chun-Ling; Guo, Ya-Feng; Luo, Yi-Wei; He, Ya-Dong

    2016-05-01

    Improving the melt viscoelasticity of poly(ethylene terephthalate) (PET) is a well-known method to obtain foamable PET. The aim of this study is to prepare high melt strength PET and evaluate the influence of rheological properties of PET on the foaming behavior. For this purpose, pyromelliticdianhydride was used as the chain extender to modify a linear PET through melt reactive processing. The rheological properties of the unmodified and modified PETs were measured by a dynamic rheometer. Results showed that the modified PET had higher complex viscosity than the unmodified one. Furthermore, the batch foaming by using supercritical CO2 as a blowing agent was carried to evaluate the foamability of modified PETs. It was found that an enlarged foaming temperature window was obtained for modified PETs compared to unmodified PET. Moreover, the modified PETs foams exhibited higher expansion ratio, smaller cell size and higher cell density at high temperatures than the neat PET.

  15. Effects of Regularisation Priors and Anatomical Partial Volume Correction on Dynamic PET Data

    NASA Astrophysics Data System (ADS)

    Caldeira, Liliana L.; Silva, Nuno da; Scheins, Jürgen J.; Gaens, Michaela E.; Shah, N. Jon

    2015-08-01

    Dynamic PET provides temporal information about the tracer uptake. However, each PET frame has usually low statistics, resulting in noisy images. Furthermore, PET images suffer from partial volume effects. The goal of this study is to understand the effects of prior regularisation on dynamic PET data and subsequent anatomical partial volume correction. The Median Root Prior (MRP) regularisation method was used in this work during reconstruction. The quantification and noise in image-domain and time-domain (time-activity curves) as well as the impact on parametric images is assessed and compared with Ordinary Poisson Ordered Subset Expectation Maximisation (OP-OSEM) reconstruction with and without Gaussian filter. This study shows the improvement in PET images and time-activity curves (TAC) in terms of noise as well as in the parametric images when using prior regularisation in dynamic PET data. Anatomical partial volume correction improves the TAC and consequently, parametric images. Therefore, the use of MRP with anatomical partial volume correction is of interest for dynamic PET studies.

  16. Prognostic Value of Bone Marrow Tracer Uptake Pattern in Baseline PET Scans in Hodgkin Lymphoma: Results from an International Collaborative Study.

    PubMed

    Zwarthoed, Colette; El-Galaly, Tarec Cristoffer; Canepari, Maria; Ouvrier, Matthieu John; Viotti, Julien; Ettaiche, Marc; Viviani, Simonetta; Rigacci, Luigi; Trentin, Livio; Rusconi, Chiara; Luminari, Stefano; Cantonetti, Maria; Bolis, Silvia; Borra, Anna; Darcourt, Jacques; Salvi, Flavia; Subocz, Edyta; Tajer, Joanna; Kulikowski, Waldemar; Malkowski, Bogdan; Zaucha, Jan Maciej; Gallamini, Andrea

    2017-08-01

    PET/CT-ascertained bone marrow involvement (BMI) constitutes the single most important reason for upstaging by PET/CT in Hodgkin lymphoma (HL). However, BMI assessment in PET/CT can be challenging. This study analyzed the clinicopathologic correlations and prognostic meaning of different patterns of bone marrow (BM) 18 F-FDG uptake in HL. Methods: One hundred eighty newly diagnosed early unfavorable and advanced-stage HL patients, all scanned at baseline and after 2 adriamycin-bleomycin-vinblastine-dacarbazine (ABVD) courses with 18 F-FDG PET, enrolled in 2 international studies aimed at assessing the role of interim PET scanning in HL, were retrospectively included. Patients were treated with ABVD × 4-6 cycles and involved-field radiation when needed, and no treatment adaptation on interim PET scanning was allowed. Two masked reviewers independently reported the scans. Results: Thirty-eight patients (21.1%) had focal lesions (fPET + ), 10 of them with a single (unifocal) and 28 with multiple (multifocal) BM lesions. Fifty-three patients (29.4%) had pure strong (>liver) diffuse uptake (dPET + ) and 89 (48.4%) showed no or faint (≤liver) BM uptake (nPET + ). BM biopsy was positive in 6 of 38 patients (15.7%) for fPET + , in 1 of 53 (1.9%) for dPET + , and in 5 of 89 (5.6%) for nPET + dPET + was correlated with younger age, higher frequency of bulky disease, lower hemoglobin levels, higher leukocyte counts, and similar diffuse uptake in the spleen. Patients with pure dPET + had a 3-y progression-free survival identical to patients without any 18 F-FDG uptake (82.9% and 82.2%, respectively, P = 0.918). However, patients with fPET+ (either unifocal or multifocal) had a 3-y progression-free survival significantly inferior to patients with dPET+ and nPET+ (66.7% and 82.5%, respectively, P = 0.03). The κ values for interobserver agreement were 0.84 for focal uptake and 0.78 for diffuse uptake. Conclusion: We confirmed that 18 F-FDG PET scanning is a reliable tool for BMI assessment in HL, and BM biopsy is no longer needed for routine staging. Moreover, the interobserver agreement for BMI in this study proved excellent and only focal 18 F-FDG BM uptake should be considered as a harbinger of HL. © 2017 by the Society of Nuclear Medicine and Molecular Imaging.

  17. Driving with pets and motor vehicle collision involvement among older drivers: a prospective population-based study

    PubMed Central

    Huisingh, Carrie; Levitan, Emily B.; Irvin, Marguerite R.; Owsley, Cynthia; McGwin, Gerald

    2016-01-01

    Objective Distracted driving is a major cause of motor vehicle collision (MVC) involvement. Pets have been identified as potential distraction to drivers, particularly in the front. This type of distraction could be worse for those with impairment in the cognitive aspects of visual processing. The purpose of this study is to evaluate the association between driving with pets and rates of motor vehicle collision involvementin a cohort of older drivers. Methods A three-year prospective was conducted in a population-based sample of 2000 licensed drivers aged 70 years and older. At the baseline visit, a trained interviewer asked participants about pet ownership, whether they drive with pets, how frequently, and where the pet sits in the vehicle. Motor vehicle collision (MVC) involvement during the three-year study period was obtained from the Alabama Department of Public Safety. At-fault status was determined by the police officer who arrived on the scene. Participants were followed until the earliest of death, driving cessation, or end of the study period. Poisson regression was used to calculate crude and adjusted rate ratios (RR) examining the association between pet ownership, presence of a pet in a vehicle, frequency of driving with a pet, and location of the pet inside with vehicle with any and at-fault MVC involvement. We examined whether the associations differed by higher order visual processing impairment status, as measured by Useful Field Of View, Trails B, and Motor-free Visual Perception Test. Results Rates of crash involvement were similar for older adults who have ever driven with a pet compared to those who never drove with their pet (RR=1.15, 95% CI 0.76-1.75). Drivers who reported always or sometimes driving with their pet had higherMVC rates compared topet owners who never drive with a pet, but this association was not statistically significant (RR=1.39, 95% CI 0.86-2.24). In terms of location, those reporting having a pet frequently ride in the front of the vehicle had similar rates of MVC involvement compared to those who did not drive with a pet in the front. A similar pattern of results was observed for at-fault MVCs. This association was not modified by visual processing impairment status. Conclusion The current study demonstrates a positive but non-significant association between frequently driving with pets and MVC involvement. More research is needed, particularly on restraint use and whether the pet was in the car at the time of the crash, to help characterize the public safety benefit of regulations on driving with pets. PMID:26774042

  18. 11C-Methionine Positron Emission Tomography/Computed Tomography Versus 18F-Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography in Evaluation of Residual or Recurrent World Health Organization Grades II and III Meningioma After Treatment.

    PubMed

    Tomura, Noriaki; Saginoya, Toshiyuki; Goto, Hiromi

    2018-04-02

    The aim of this study was to determine the assessment of positron emission tomography-computed tomography using C-methionine (MET PET/CT) for World Health Organization (WHO) grades II and III meningiomas; MET PET/CT was compared with PET/CT using F-fluorodeoxy glucose (FDG PET/CT). This study was performed in 17 cases with residual and/or recurrent WHO grades II and III meningiomas. Two neuroradiologists reviewed both PET/CT scans. For agreement, the κ coefficient was measured. Difference in tumor-to-normal brain uptake ratios (T/N ratios) between 2 PET/CT scans was analyzed. Correlation between the maximum tumor size and T/N ratio in PET/CT was studied. For agreement by both reviewers, the κ coefficient was 0.51 (P < 0.05). The T/N ratio was significantly higher for MET PET/CT (3.24 ± 1.36) than for FDG PET/CT (0.93 ± 0.44) (P < 0.01). C-methionine ratio significantly correlated with tumor size (y = 8.1x + 16.3, n = 22, P < 0.05), but FDG ratio did not CONCLUSIONS: C-methionine PET/CT has superior potential for imaging of WHO grades II and III meningiomas with residual or recurrent tumors compared with FDG PET/CT.

  19. [A report on clinical PET activities in Germany].

    PubMed

    Tashiro, M; Kubota, K; Itoh, M; Sasaki, H; Moser, E

    1999-09-01

    Clinical diagnostic procedure using positron emission tomography (PET) requires high costs. To promote clinical use of PET, sociomedical evaluation is necessary. In this paper, sociomedical situations concerning clinical use of PET in Germany is reported. Some comparisons are made between Japan and this country putting emphases on several points such as 1) number of cyclotron and PET facilities, 2) social restriction to transportation of radioisotopes, 3) activities of satellite PET facilities, and 4) clinical indications for PET studies. Number of cyclotron was larger in Japan (29) than in Germany (17), but number of PET facilities was larger in Germany (47) than in Japan (29). The reason seems that in Germany transportation and buying of radioisotopes is less restricted. Hence, more than half of PET facilities in Germany are "satellite facilities" which do not have their own cyclotrons. Radioisotope distribution seems to serve as a backbone of "satellite concept." Additionally in Germany, list of clinical indications for PET study is almost completed and now is widely in applied to most cases. To promote clinical use of PET in Japan, the German system might serve as an important socioeconomic model in Europe instead of the United States.

  20. Joint Segmentation of Anatomical and Functional Images: Applications in Quantification of Lesions from PET, PET-CT, MRI-PET, and MRI-PET-CT Images

    PubMed Central

    Bagci, Ulas; Udupa, Jayaram K.; Mendhiratta, Neil; Foster, Brent; Xu, Ziyue; Yao, Jianhua; Chen, Xinjian; Mollura, Daniel J.

    2013-01-01

    We present a novel method for the joint segmentation of anatomical and functional images. Our proposed methodology unifies the domains of anatomical and functional images, represents them in a product lattice, and performs simultaneous delineation of regions based on random walk image segmentation. Furthermore, we also propose a simple yet effective object/background seed localization method to make the proposed segmentation process fully automatic. Our study uses PET, PET-CT, MRI-PET, and fused MRI-PET-CT scans (77 studies in all) from 56 patients who had various lesions in different body regions. We validated the effectiveness of the proposed method on different PET phantoms as well as on clinical images with respect to the ground truth segmentation provided by clinicians. Experimental results indicate that the presented method is superior to threshold and Bayesian methods commonly used in PET image segmentation, is more accurate and robust compared to the other PET-CT segmentation methods recently published in the literature, and also it is general in the sense of simultaneously segmenting multiple scans in real-time with high accuracy needed in routine clinical use. PMID:23837967

  1. The role of fluorine-18-fluorodeoxyglucose positron emission tomography in aggressive histological subtypes of thyroid cancer: an overview.

    PubMed

    Treglia, Giorgio; Annunziata, Salvatore; Muoio, Barbara; Salvatori, Massimo; Ceriani, Luca; Giovanella, Luca

    2013-01-01

    Aggressive histological subtypes of thyroid cancer are rare and have a poor prognosis. The most important aggressive subtypes of thyroid cancer are Hürthle cell carcinoma (HCTC) and anaplastic and poorly differentiated carcinoma (ATC and PDTC). The American Thyroid Association recently published guidelines for the management of patients with ATC, but no specific guidelines have been done about HCTC. We performed an overview of the literature about the role of Fluorine-18-Fluorodeoxyglucose positron emission tomography or positron emission tomography/computed tomography (FDG-PET or PET/CT) in aggressive histological subtypes of thyroid cancer. Only few original studies about the role of FDG-PET or PET/CT in HCTC, PDTC, and ATC have been published in the literature. FDG-PET or PET/CT seems to be useful in staging or followup of invasive and metastatic HCTC. FDG-PET or PET/CT should be used in patients with ATC in initial staging and in the followup after surgery to evaluate metastatic disease. Some authors suggest the use of FDG-PET/CT in staging of PDTC, but more studies are needed to define the diagnostic use of FDG-PET/CT in this setting. Limited experience suggests the usefulness of FDG-PET or PET/CT in patients with more aggressive histological subtypes of DTC. However, DTC presenting as radioiodine refractory and FDG-PET positive should be considered aggressive tumours with poor prognosis.

  2. Magnetic Resonance-based Motion Correction for Quantitative PET in Simultaneous PET-MR Imaging.

    PubMed

    Rakvongthai, Yothin; El Fakhri, Georges

    2017-07-01

    Motion degrades image quality and quantitation of PET images, and is an obstacle to quantitative PET imaging. Simultaneous PET-MR offers a tool that can be used for correcting the motion in PET images by using anatomic information from MR imaging acquired concurrently. Motion correction can be performed by transforming a set of reconstructed PET images into the same frame or by incorporating the transformation into the system model and reconstructing the motion-corrected image. Several phantom and patient studies have validated that MR-based motion correction strategies have great promise for quantitative PET imaging in simultaneous PET-MR. Copyright © 2017 Elsevier Inc. All rights reserved.

  3. Optimization of PET-MR Registrations for Nonhuman Primates Using Mutual Information Measures: A Multi-Transform Method (MTM)

    PubMed Central

    Sandiego, Christine M.; Weinzimmer, David; Carson, Richard E.

    2012-01-01

    An important step in PET brain kinetic analysis is the registration of functional data to an anatomical MR image. Typically, PET-MR registrations in nonhuman primate neuroreceptor studies used PET images acquired early post-injection, (e.g., 0–10 min) to closely resemble the subject’s MR image. However, a substantial fraction of these registrations (~25%) fail due to the differences in kinetics and distribution for various radiotracer studies and conditions (e.g., blocking studies). The Multi-Transform Method (MTM) was developed to improve the success of registrations between PET and MR images. Two algorithms were evaluated, MTM-I and MTM-II. The approach involves creating multiple transformations by registering PET images of different time intervals, from a dynamic study, to a single reference (i.e., MR image) (MTM-I) or to multiple reference images (i.e., MR and PET images pre-registered to the MR) (MTM-II). Normalized mutual information was used to compute similarity between the transformed PET images and the reference image(s) to choose the optimal transformation. This final transformation is used to map the dynamic dataset into the animal’s anatomical MR space, required for kinetic analysis. The chosen transformed from MTM-I and MTM-II were evaluated using visual rating scores to assess the quality of spatial alignment between the resliced PET and reference. One hundred twenty PET datasets involving eleven different tracers from 3 different scanners were used to evaluate the MTM algorithms. Studies were performed with baboons and rhesus monkeys on the HR+, HRRT, and Focus-220. Successful transformations increased from 77.5%, 85.8%, to 96.7% using the 0–10 min method, MTM-I, and MTM-II, respectively, based on visual rating scores. The Multi-Transform Methods proved to be a robust technique for PET-MR registrations for a wide range of PET studies. PMID:22926293

  4. Exploring the differences between pet and non-pet owners: Implications for human-animal interaction research and policy

    PubMed Central

    Saunders, Jessica; Parast, Layla; Babey, Susan H.; Miles, Jeremy V.

    2017-01-01

    There is conflicting evidence about whether living with pets results in better mental and physical health outcomes, with the majority of the empirical research evidence being inconclusive due to methodological limitations. We briefly review the research evidence, including the hypothesized mechanisms through which pet ownership may influence health outcomes. This study examines how pet and non-pet owners differ across a variety of socio-demographic and health measures, which has implications for the proper interpretation of a large number of correlational studies that attempt to draw causal attributions. We use a large, population-based survey from California administered in 2003 (n = 42,044) and find that pet owners and non-pet owners differ across many traits, including gender, age, race/ethnicity, living arrangements, and income. We include a discussion about how the factors associated with the selection into the pet ownership group are related to a range of mental and physical health outcomes. Finally, we provide guidance on how to properly model the effects of pet ownership on health to accurately estimate this relationship in the general population. PMID:28644848

  5. Strategy of Using Intratreatment Hypoxia Imaging to Selectively and Safely Guide Radiation Dose De-escalation Concurrent With Chemotherapy for Locoregionally Advanced Human Papillomavirus–Related Oropharyngeal Carcinoma

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lee, Nancy, E-mail: leen2@mskcc.org; Schoder, Heiko; Beattie, Brad

    Purpose: To report a small substudy of an ongoing large, multi-arm study using functional imaging to assess pre-/intratreatment hypoxia for all head and neck cancer, in which we hypothesized that pre- and early-treatment hypoxia assessment using functional positron emission tomography (PET) imaging may help select which human papillomavirus (HPV)-positive (HPV{sup +}) oropharyngeal cancer (OPC) patients can safely receive radiation de-escalation without jeopardizing treatment outcomes. Methods and Materials: Patients with HPV{sup +} oropharyngeal carcinoma were enrolled on an institutional review board–approved prospective study of which de-escalation based on imaging response was done for node(s) only. Pretreatment {sup 18}F-fluorodeoxyglucose and dynamic {sup 18}F-FMISOmore » (fluoromisonidazole) positron emission tomography (PET) scans were performed. For patients with pretreatment hypoxia on{sup 18}F-FMISO PET (defined as a >1.2 tumor to muscle standard uptake value ratio), a repeat scan was done 1 week after chemoradiation. Patients without pretreatment hypoxia or with resolution of hypoxia on repeat scan received a 10-Gy dose reduction to metastatic lymph node(s). The 2-year local, regional, distant metastasis–free, and overall survival rates were estimated using the Kaplan-Meier product-limit method. A subset of patients had biopsy of a hypoxic node done under image guidance. Results: Thirty-three HPV{sup +} OPC patients were enrolled in this pilot study. One hundred percent showed pretreatment hypoxia (at primary site and/or node[s]), and among these, 48% resolved (at primary site and/or node[s]); 30% met criteria and received 10-Gy reduction to the lymph node(s). At the median follow-up of 32 months (range, 21-61 months), the 2-year locoregional control rate was 100%. One patient failed distantly with persistence of hypoxia on {sup 18}F-FMISO PET. The 2-year distant metastasis–free rate was 97%. The 2-year OS rate was 100%. Hypoxia on imaging was confirmed pathologically. Conclusions: Hypoxia is present in HPV{sup +} tumors but resolves within 1 week of treatment in 48% of cases either at the primary site and/or lymph node(s). Our 100% locoregional control rate suggests that intratreatment functional imaging used to selectively de-escalate node(s) to 60 Gy was confirmed safe using our stringent imaging criteria. Intratreatment functional imaging warrants further study to determine its ultimate role in de-escalation treatment strategies.« less

  6. Strategy of Using Intratreatment Hypoxia Imaging to Selectively and Safely Guide Radiation Dose De-escalation Concurrent With Chemotherapy for Locoregionally Advanced Human Papillomavirus-Related Oropharyngeal Carcinoma.

    PubMed

    Lee, Nancy; Schoder, Heiko; Beattie, Brad; Lanning, Ryan; Riaz, Nadeem; McBride, Sean; Katabi, Nora; Li, Duan; Yarusi, Brett; Chan, Susie; Mitrani, Lindsey; Zhang, Zhigang; Pfister, David G; Sherman, Eric; Baxi, Shrujal; Boyle, Jay; Morris, Luc G T; Ganly, Ian; Wong, Richard; Humm, John

    2016-09-01

    To report a small substudy of an ongoing large, multi-arm study using functional imaging to assess pre-/intratreatment hypoxia for all head and neck cancer, in which we hypothesized that pre- and early-treatment hypoxia assessment using functional positron emission tomography (PET) imaging may help select which human papillomavirus (HPV)-positive (HPV(+)) oropharyngeal cancer (OPC) patients can safely receive radiation de-escalation without jeopardizing treatment outcomes. Patients with HPV(+) oropharyngeal carcinoma were enrolled on an institutional review board-approved prospective study of which de-escalation based on imaging response was done for node(s) only. Pretreatment (18)F-fluorodeoxyglucose and dynamic (18)F-FMISO (fluoromisonidazole) positron emission tomography (PET) scans were performed. For patients with pretreatment hypoxia on(18)F-FMISO PET (defined as a >1.2 tumor to muscle standard uptake value ratio), a repeat scan was done 1 week after chemoradiation. Patients without pretreatment hypoxia or with resolution of hypoxia on repeat scan received a 10-Gy dose reduction to metastatic lymph node(s). The 2-year local, regional, distant metastasis-free, and overall survival rates were estimated using the Kaplan-Meier product-limit method. A subset of patients had biopsy of a hypoxic node done under image guidance. Thirty-three HPV(+) OPC patients were enrolled in this pilot study. One hundred percent showed pretreatment hypoxia (at primary site and/or node[s]), and among these, 48% resolved (at primary site and/or node[s]); 30% met criteria and received 10-Gy reduction to the lymph node(s). At the median follow-up of 32 months (range, 21-61 months), the 2-year locoregional control rate was 100%. One patient failed distantly with persistence of hypoxia on (18)F-FMISO PET. The 2-year distant metastasis-free rate was 97%. The 2-year OS rate was 100%. Hypoxia on imaging was confirmed pathologically. Hypoxia is present in HPV(+) tumors but resolves within 1 week of treatment in 48% of cases either at the primary site and/or lymph node(s). Our 100% locoregional control rate suggests that intratreatment functional imaging used to selectively de-escalate node(s) to 60 Gy was confirmed safe using our stringent imaging criteria. Intratreatment functional imaging warrants further study to determine its ultimate role in de-escalation treatment strategies. Copyright © 2016 Elsevier Inc. All rights reserved.

  7. Towards integration of PET/MR hybrid imaging into radiation therapy treatment planning

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Paulus, Daniel H., E-mail: daniel.paulus@imp.uni-erlangen.de; Thorwath, Daniela; Schmidt, Holger

    2014-07-15

    Purpose: Multimodality imaging has become an important adjunct of state-of-the-art radiation therapy (RT) treatment planning. Recently, simultaneous PET/MR hybrid imaging has become clinically available and may also contribute to target volume delineation and biological individualization in RT planning. For integration of PET/MR hybrid imaging into RT treatment planning, compatible dedicated RT devices are required for accurate patient positioning. In this study, prototype RT positioning devices intended for PET/MR hybrid imaging are introduced and tested toward PET/MR compatibility and image quality. Methods: A prototype flat RT table overlay and two radiofrequency (RF) coil holders that each fix one flexible body matrixmore » RF coil for RT head/neck imaging have been evaluated within this study. MR image quality with the RT head setup was compared to the actual PET/MR setup with a dedicated head RF coil. PET photon attenuation and CT-based attenuation correction (AC) of the hardware components has been quantitatively evaluated by phantom scans. Clinical application of the new RT setup in PET/MR imaging was evaluated in anin vivo study. Results: The RT table overlay and RF coil holders are fully PET/MR compatible. MR phantom and volunteer imaging with the RT head setup revealed high image quality, comparable to images acquired with the dedicated PET/MR head RF coil, albeit with 25% reduced SNR. Repositioning accuracy of the RF coil holders was below 1 mm. PET photon attenuation of the RT table overlay was calculated to be 3.8% and 13.8% for the RF coil holders. With CT-based AC of the devices, the underestimation error was reduced to 0.6% and 0.8%, respectively. Comparable results were found within the patient study. Conclusions: The newly designed RT devices for hybrid PET/MR imaging are PET and MR compatible. The mechanically rigid design and the reproducible positioning allow for straightforward CT-based AC. The systematic evaluation within this study provides the technical basis for the clinical integration of PET/MR hybrid imaging into RT treatment planning.« less

  8. Report on the development and application of PET/CT in mainland China

    PubMed Central

    Zhou, Xiang; Liu, Jianjun; Huang, Gang

    2017-01-01

    Purpose To examine the development and application of systems combining positron emission and x-ray-computed tomography systems (PET/CTs) in mainland China. Methods Using a questionnaire, we surveyed Chinese medical institutions on a variety topics relating to their PET/CT systems and its use. The respondents had PET/CTs installed and in clinical use before 31 December 2015. We examined the clinical scenarios to which Chinese PET/CTs were applied by reviewing the related Chinese and international literature from the start of 1995 to the end of 2013; these papers were found by searching the Wanfang and PubMed databases, respectively. The data were then classified and analyzed statistically. Results At the end of 2015, there were 240 PET/CTs and 101 medical cyclotrons in mainland China. The total number of PET studies performed in 2015 was 469,364. The main clinical applications of PET were found to be diagnostic fludeoxyglucose (18F-FDG) imaging and oncological imaging. A minority of PET/CT studies were performed using 11C-choline and other imaging agents. The number of papers relating to clinical use of PET/CT in mainland China increased each year over the period of study, in both the Chinese and international literature. Despite this progress, important problems were also apparent, including unbalanced regional development and the limited quality of the research. Conclusions This study provides detailed information for understanding the development PET/CT technology in mainland China, along with its geographical distribution and clinical application. It may thus prove a useful reference for all those involved in planning the future of PET/CT in China. PMID:28969081

  9. The impact of FDG-PET/CT in the management of patients with vulvar and vaginal cancer.

    PubMed

    Robertson, N L; Hricak, H; Sonoda, Y; Sosa, R E; Benz, M; Lyons, G; Abu-Rustum, N R; Sala, E; Vargas, H A

    2016-03-01

    To evaluate the changes in prognostic impression and patient management following PET/CT in patients with vulvar and vaginal carcinoma; and to compare PET/CT findings with those of conventional imaging modalities. We summarized prospectively and retrospectively collected data for 50 consecutive patients from our institution that enrolled in the National Oncologic PET Registry and underwent FDG-PET/CT for a suspected or known primary or recurrent vulvar/vaginal cancer. 54/83 (65%) studies included had a diagnosis of vulvar cancer, and the remaining 29/83 (35%), a diagnosis of vaginal cancer. Following FDG-PET/CT, the physician's prognostic impression changed in 51% of cases. A change in patient management, defined as a change to/from a non-interventional strategy (observation or additional imaging), to/from an interventional strategy (biopsy or treatment), was documented in 36% of studies. The electronic records demonstrated that 95% of the management strategies recorded in the physician questionnaires were implemented as planned. MRI and/or CT were performed within one month of the FDG-PET/CT in 20/83 (24%) and 28/83 (34%) cases, respectively. FDG-PET/CT detected nodes suspicious for metastases on 29/83 (35%) studies performed. MRI and CT detected positive nodes on 6 and 11 studies respectively. Distant metastases were identified in 10 cases imaged with FDG-PET and 5 cases that had additional conventional CT imaging. All suspicious lesions seen on CT were positively identified on PET/CT. In 4 cases, an abnormality identified on PET/CT, was not seen on diagnostic CT. FDG-PET/CT may play an important role in the management of vulvar and vaginal carcinoma. Copyright © 2015 Elsevier Inc. All rights reserved.

  10. Local delivery of controlled-release simvastatin to improve the biocompatibility of polyethylene terephthalate artificial ligaments for reconstruction of the anterior cruciate ligament.

    PubMed

    Zhang, Peng; Han, Fei; Li, Yunxia; Chen, Jiwu; Chen, Tianwu; Zhi, Yunlong; Jiang, Jia; Lin, Chao; Chen, Shiyi; Zhao, Peng

    2016-01-01

    The Ligament Advanced Reinforcement System has recently been widely used as the primary graft of choice in anterior cruciate ligament (ACL) reconstruction. But the biological graft-bone healing still remains a problem. Previous studies have shown that simvastatin (SIM) stimulates bone formation. The objective of this study was to investigate whether surface coating with collagen containing low-dose SIM microsphere could enhance the surface biocompatibility of polyethylene terephthalate (PET) artificial ligaments to accelerate graft-to-bone healing. The in vitro studies demonstrated that bone marrow stromal cells on the collagen-coated PET scaffolds (COL/PET) and simvastatin/collagen-coated PET scaffolds (SIM/COL/PET) proliferated vigorously. Compared with the PET group and the COL/PET group, SIM could induce bone marrow stromal cells' osteoblastic differentiation, high alkaline phosphatase activity, more mineralization deposition, and more expression of osteoblast-related genes, such as osteocalcin, runt-related transcription factor 2, bone morphogenetic protein-2, and vascular endothelial growth factor, in the SIM/COL/PET group. In vivo, rabbits received ACL reconstruction with different scaffolds. Histological analysis demonstrated that graft-bone healing was significantly greater with angiogenesis and osteogenesis in the SIM/COL/PET group than the other groups. In addition, biomechanical testing at the eighth week demonstrated a significant increase in the ultimate failure load and stiffness in the SIM/COL/PET group. The low dose of SIM-sustained release from SIM/COL/PET promoted the graft-bone healing via its effect on both angiogenesis and osteogenesis. This study suggested that collagen containing low-dose SIM microsphere coating on the surface of PET artificial ligaments could be potentially applied for ACL reconstruction.

  11. An inter-laboratory comparison study of image quality of PET scanners using the NEMA NU 2-2001 procedure for assessment of image quality

    NASA Astrophysics Data System (ADS)

    Bergmann, Helmar; Dobrozemsky, Georg; Minear, Gregory; Nicoletti, Rudolf; Samal, Martin

    2005-05-01

    An inter-laboratory comparison study was conducted to assess the image quality of PET scanners in Austria. The survey included both dedicated PET scanners (D-PET, n = 8) and coincidence cameras (GC-PET, n = 7). Measurement of image quality was based on the NEMA (National Electrical Manufacturers Association) NU 2-2001 protocol and the IEC (International Electrotechnical Commission) body phantom. The latter contains six fillable spheres ranging in diameter from 37 mm down to 10 mm and a 'lung' insert. The two largest lesions L1-2 simulate cold lesions, the four smaller ones (L3-6) are filled with 18F and activity concentration ratios relative to background of 8:1 and 4:1, respectively. Acquisition and reconstruction in the study employed the participating institutes' standard oncological processing protocol. Calculation of contrast of the spheres was performed with a fully automated procedure. Contrast quality indices (CQIs) reflecting global performance were obtained by summing individual contrast values. Other image quality parameters calculated according to the NEMA protocol were background variability and relative error for correction of attenuation and scatter. Contrast values obtained were 61 ± 16 and 37 ± 14 for L1 (per cent contrast ± SD for D-PET and GC-PET, respectively), 57 ± 16 and 29 ± 16 for L2, 46 ± 10 and 26 ± 6.3 for L3, 37 ± 10 and 15 ± 4.3 for L4, 26 ± 11.5 and 6.1 ± 2.5 for L5, 14 ± 7.1 and 2.6 ± 2.6 for L6, with D-PET systems consistently being superior to GC-PET systems. CQIs permitted ranking of the scanners, also demonstrating a clear distinction between D-PET and GC-PET systems. Background variability was largest for GC-PET systems; the relative error of attenuation and scatter correction was significantly correlated with image quality for D-PET systems only. The study demonstrated considerable differences in image quality not only between GC-PET and D-PET systems but also between individual D-PET systems with possible consequences for clinical interpretation of images and measurement of quantitative indices such as the standardized uptake value. The study provided valuable feedback to the participants as well as baseline data for improving interchangeability of PET images and of quantitative indices between different laboratories.

  12. A six-year longitudinal PET study of (+)-[11C]DTBZ binding to the VMAT2 in monkey brain.

    PubMed

    Kilbourn, Michael R; Koeppe, Robert A

    2017-12-01

    The longitudinal reproducibility of in vivo binding potential measures for [ 11 C]dihydrotetrabenazine ([ 11 C]DTBZ) binding to the vesicular monoamine transporter 2 (VMAT2) site in primate brain was examined using a unique dataset of repeated control PET imaging studies. Forty-one dynamic [ 11 C]DTBZ PET studies were completed in a single rhesus monkey. Imaging equipment (microPET P4), personnel, radiotracer characteristics (injected mass amounts, molar activity) and image data analysis (BP ND-Logan ) were consistent throughout the entire sequence of PET studies. Same day reproducibility of BP ND-Logan estimates of specific binding was very good (-3% and -7% changes) for two control-control sessions. Over the full 74 months, the average BP ND-Logan value for [ 11 C]DTBZ-PET studies was 4.19±0.52, for a variance of 12%. No age-dependent change in binding potentials was observed over the six-year period. If the technical variables associated with PET scanner are consistently maintained, including PET scanner, imaging procedures and radiotracer preparation, in vivo biochemistry can be reproducibly measured in the primate brain over a multi-year period of time. Copyright © 2017 Elsevier Inc. All rights reserved.

  13. Simulation study comparing the helmet-chin PET with a cylindrical PET of the same number of detectors

    NASA Astrophysics Data System (ADS)

    Ahmed, Abdella M.; Tashima, Hideaki; Yoshida, Eiji; Nishikido, Fumihiko; Yamaya, Taiga

    2017-06-01

    There is a growing interest in developing brain PET scanners with high sensitivity and high spatial resolution for early diagnosis of neurodegenerative diseases and studies of brain functions. Sensitivity of the PET scanner can be improved by increasing the solid angle. However, conventional PET scanners are designed based on a cylindrical geometry, which may not be the most efficient design for brain imaging in terms of the balance between sensitivity and cost. We proposed a dedicated brain PET scanner based on a hemispheric shape detector and a chin detector (referred to as the helmet-chin PET), which is designed to maximize the solid angle by increasing the number of lines-of-response in the hemisphere. The parallax error, which PET scanners with a large solid angle tend to have, can be suppressed by the use of depth-of-interaction detectors. In this study, we carry out a realistic evaluation of the helmet-chin PET using Monte Carlo simulation based on the 4-layer GSO detector which consists of a 16  ×  16  ×  4 array of crystals with dimensions of 2.8  ×  2.8  ×  7.5 mm3. The purpose of this simulation is to show the gain in imaging performance of the helmet-chin PET compared with the cylindrical PET using the same number of detectors in each configuration. The sensitivity of the helmet-chin PET evaluated with a cylindrical phantom has a significant increase, especially at the top of the (field-of-view) FOV. The peak-NECR of the helmet-chin PET is 1.4 times higher compared to the cylindrical PET. The helmet-chin PET provides relatively low noise images throughout the FOV compared to the cylindrical PET which exhibits enhanced noise at the peripheral regions. The results show the helmet-chin PET can significantly improve the sensitivity and reduce the noise in the reconstructed images.

  14. SU-F-I-57: Evaluate and Optimize PET Acquisition Overlap in 18F-FDG Oncology Wholebody PET/CT: Can We Scan PET Faster?

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang, J; Natwa, M; Hall, NC

    Purpose: The longer patient has to remain on the table during PET imaging, the higher the likelihood of motion artifacts due to patient discomfort. This study was to investigate and optimize PET acquisition overlap in 18F-FDG oncology wholebody PET/CT to speed up PET acquisition and improve patient comfort. Methods: Wholebody 18F-FDG PET/CT of phantoms, 8 pre-clinical patients (beagles) and 5 clinical oncology patients were performed in 90s/bed on a time-of-flight Gemini TF 64 system. Imaging of phantoms and beagles was acquired with reduced PET overlaps (40%, 33%, 27%, 20%, 13% and no overlap) in addition to the system default (53%).more » In human studies, 1 or 2 reduced overlaps from the listed options were used to acquire PET/CT sweeps right after the default standard of care imaging. Image quality was blindly reviewed using visual scoring criteria and quantitative SUV assessment. NEMA PET sensitivity was performed under different overlaps. Results: All PET exams demonstrated no significant impact on the visual grades for overlaps >20%. Blinded reviews assigned the best visual scores to PET using overlaps 53%–27%. Reducing overlap to 27% for oncology patients (12-bed) saved an average of ∼40% acquisition time (11min) compared to using the default overlap (18min). No significant SUV variances were found when reducing overlap to half of default for cerebellum, lung, heart, aorta, liver, fat, muscle, bone marrow, thighs and target lesions (p>0.05), except expected variability in urinary system. Conclusion: This study demonstrated by combined phantom, pre-clinical and clinical PET/CT scans that PET acquisition overlap in axial of today’s systems can be reduced and optimized. It showed that a reduction of PET acquisition overlap to 27% (half of system default) can be implemented to reduce table time by ∼40% to improve patient comfort and minimize potential motion artifacts, without prominently degrading image quality or compromising PET quantification.« less

  15. Injuries caused by pets in Asian urban households: a cross-sectional telephone survey

    PubMed Central

    Chan, Emily Y Y; Gao, Yang; Li, Liping; Lee, Po Yi

    2017-01-01

    Objectives Little is known about pet-related injuries in Asian populations. This study primarily aimed to investigate the incidence rate of pet-related household injuries in Hong Kong, an urban Chinese setting. Setting Cantonese-speaking non-institutionalised population of all ages in Hong Kong accessible by telephone land-line. Participants A total of 43 542 telephone numbers were dialled and 6570 residents successfully completed the interviews. Primary and secondary outcome measures Data of pet-related household injuries in the previous 12 months, pet ownership and socio-demographic characteristics were collected with a questionnaire. Direct standardisation of the incidence rates of pet-related household injuries by gender and age to the 2009 Hong Kong Population Census was estimated. Univariate and multivariate analyses were performed to estimate risks of socio-demographic factors and pet ownership for the injury. Results A total of 84 participants experienced pet-related household injuries in the past 12 months, with an overall person-based incidence rate of 1.28%. The majority of the victims were injured once (69.6%). Cats (51.6%) were the most common pets involved. Pet owners were at an extremely higher risk after controlling for other factors (adjusted OR: 52.0, 95% CI 22.1 to 98.7). Females, the unmarried, those with higher monthly household income and those living in lower-density housing were more likely to be injured by pets. Conclusions We project a pet-related household injury incidence rate of 1.24% in the general Hong Kong population, with 86 334 residents sustaining pet-related injuries every year. Pet ownership puts people at extremely high risk, especially the unmarried. Further studies should focus on educating pet owners to reduce pet-related injuries in urban Greater China. PMID:28110284

  16. Small animal simultaneous PET/MRI: initial experiences in a 9.4 T microMRI

    NASA Astrophysics Data System (ADS)

    Harsha Maramraju, Sri; Smith, S. David; Junnarkar, Sachin S.; Schulz, Daniela; Stoll, Sean; Ravindranath, Bosky; Purschke, Martin L.; Rescia, Sergio; Southekal, Sudeepti; Pratte, Jean-François; Vaska, Paul; Woody, Craig L.; Schlyer, David J.

    2011-04-01

    We developed a non-magnetic positron-emission tomography (PET) device based on the rat conscious animal PET that operates in a small-animal magnetic resonance imaging (MRI) scanner, thereby enabling us to carry out simultaneous PET/MRI studies. The PET detector comprises 12 detector blocks, each being a 4 × 8 array of lutetium oxyorthosilicate crystals (2.22 × 2.22 × 5 mm3) coupled to a matching non-magnetic avalanche photodiode array. The detector blocks, housed in a plastic case, form a 38 mm inner diameter ring with an 18 mm axial extent. Custom-built MRI coils fit inside the positron-emission tomography (PET) device, operating in transceiver mode. The PET insert is integrated with a Bruker 9.4 T 210 mm clear-bore diameter MRI scanner. We acquired simultaneous PET/MR images of phantoms, of in vivo rat brain, and of cardiac-gated mouse heart using [11C]raclopride and 2-deoxy-2-[18F]fluoro-d-glucose PET radiotracers. There was minor interference between the PET electronics and the MRI during simultaneous operation, and small effects on the signal-to-noise ratio in the MR images in the presence of the PET, but no noticeable visual artifacts. Gradient echo and high-duty-cycle spin echo radio frequency (RF) pulses resulted in a 7% and a 28% loss in PET counts, respectively, due to high PET counts during the RF pulses that had to be gated out. The calibration of the activity concentration of PET data during MR pulsing is reproducible within less than 6%. Our initial results demonstrate the feasibility of performing simultaneous PET and MRI studies in adult rats and mice using the same PET insert in a small-bore 9.4 T MRI.

  17. Investigation of optimization-based reconstruction with an image-total-variation constraint in PET

    NASA Astrophysics Data System (ADS)

    Zhang, Zheng; Ye, Jinghan; Chen, Buxin; Perkins, Amy E.; Rose, Sean; Sidky, Emil Y.; Kao, Chien-Min; Xia, Dan; Tung, Chi-Hua; Pan, Xiaochuan

    2016-08-01

    Interest remains in reconstruction-algorithm research and development for possible improvement of image quality in current PET imaging and for enabling innovative PET systems to enhance existing, and facilitate new, preclinical and clinical applications. Optimization-based image reconstruction has been demonstrated in recent years of potential utility for CT imaging applications. In this work, we investigate tailoring the optimization-based techniques to image reconstruction for PET systems with standard and non-standard scan configurations. Specifically, given an image-total-variation (TV) constraint, we investigated how the selection of different data divergences and associated parameters impacts the optimization-based reconstruction of PET images. The reconstruction robustness was explored also with respect to different data conditions and activity up-takes of practical relevance. A study was conducted particularly for image reconstruction from data collected by use of a PET configuration with sparsely populated detectors. Overall, the study demonstrates the robustness of the TV-constrained, optimization-based reconstruction for considerably different data conditions in PET imaging, as well as its potential to enable PET configurations with reduced numbers of detectors. Insights gained in the study may be exploited for developing algorithms for PET-image reconstruction and for enabling PET-configuration design of practical usefulness in preclinical and clinical applications.

  18. Influence of content and particle size of waste pet bottles on concrete behavior at different w/c ratios.

    PubMed

    Albano, C; Camacho, N; Hernández, M; Matheus, A; Gutiérrez, A

    2009-10-01

    The goal of this work was to study the mechanical behavior of concrete with recycled Polyethylene Therephtalate (PET), varying the water/cement ratio (0.50 and 0.60), PET content (10 and 20 vol%) and the particle size. Also, the influence of the thermal degradation of PET in the concrete was studied, when the blends were exposed to different temperatures (200, 400, 600 degrees C). Results indicate that PET-filled concrete, when volume proportion and particle size of PET increased, showed a decrease in compressive strength, splitting tensile strength, modulus of elasticity and ultrasonic pulse velocity; however, the water absorption increased. On the other hand, the flexural strength of concrete-PET when exposed to a heat source was strongly dependent on the temperature, water/cement ratio, as well as on the PET content and particle size. Moreover, the activation energy was affected by the temperature, PET particles location on the slabs and water/cement ratio.

  19. Higher 5-HT1A autoreceptor binding as an endophenotype for major depressive disorder identified in high risk offspring - A pilot study.

    PubMed

    Milak, Matthew S; Pantazatos, Spiro; Rashid, Rain; Zanderigo, Francesca; DeLorenzo, Christine; Hesselgrave, Natalie; Ogden, R Todd; Oquendo, Maria A; Mulhern, Stephanie T; Miller, Jeffrey M; Burke, Ainsley K; Parsey, Ramin V; Mann, J John

    2018-04-13

    Higher serotonin-1A (5-HT 1A ) receptor binding potential (BP F ) has been found in major depressive disorder (MDD) during and between major depressive episodes. We investigated whether higher 5-HT 1A binding is a biologic trait transmitted to healthy high risk (HR) offspring of MDD probands. Data were collected contemporaneously from: nine HR, 30 depressed not-recently medicated (NRM) MDD, 18 remitted NRM MDD, 51 healthy volunteer (HV) subjects. Subjects underwent positron emission tomography (PET) using [ 11 C]WAY100635 to quantify 5-HT 1A BP F , estimated using metabolite, free fraction-corrected arterial input function and cerebellar white matter as reference region. Multivoxel pattern analyses (MVPA) of PET data evaluated group status classification of individuals. When tested across 13 regions of interest, an effect of diagnosis is found on BP F which remains significant after correction for sex, age, injected mass and dose: HR have higher BP F than HV (84.3% higher in midbrain raphe, 40.8% higher in hippocampus, mean BP F across all 13 brain regions is 49.9% ± 11.8% higher). Voxel-level BP F maps distinguish HR vs. HV. Elevated 5-HT 1A BP F appears to be a familially transmitted trait abnormality. Future studies are needed to replicate this finding in a larger cohort and demonstrate the link to the familial transmission of mood disorders. Copyright © 2018 Elsevier B.V. All rights reserved.

  20. Brain metabolism in patients with freezing of gait after hypoxic-ischemic brain injury: A pilot study.

    PubMed

    Yoon, Seo Yeon; Lee, Sang Chul; Kim, Na Young; An, Young-Sil; Kim, Yong Wook

    2017-11-01

    Movement disorders are 1 of the long-term neurological complications that can occur after hypoxic-ischemic brain injury (HIBI). However, freezing of gait (FOG) after HIBI is rare. The aim of this study was to examine the brain metabolism of patients with FOG after HIBI using F-18 fluoro-2-deoxy-D-glucose positron emission tomography (F-18 FDG PET).We consecutively enrolled 11 patients with FOG after HIBI. The patients' overall brain metabolism was measured by F-18 FDG PET, and we compared their regional brain metabolic activity with that from 15 healthy controls using a voxel-by-voxel-based statistical mapping analysis. Additionally, we correlated each patient's FOG severity with the brain metabolism using a covariance analysis.Patients with FOG had significantly decreased brain glucose metabolism in the midbrain, bilateral thalamus, bilateral cingulate gyri, right supramarginal gyrus, right angular gyrus, right paracentral lobule, and left precentral gyrus (PFDR-corrected < .01, k = 50). No significant increases in brain metabolism were noted in patients with FOG. The covariance analysis identified significant correlations between the FOG severity and the brain metabolism in the right lingual gyrus, left fusiform gyrus, and bilateral cerebellar crus I (Puncorrected < 0.001, k = 50).Our data suggest that brain regions in the gait-related neural network, including the cerebral cortex, subcortical structures, brainstem, and cerebellum, may significantly contribute to the development of FOG in HIBI. Moreover, the FOG severity may be associated with the visual cortex and cerebellar regions.

  1. The spatial distribution of pet dogs and pet cats on the island of Ireland

    PubMed Central

    2011-01-01

    Background There is considerable international research regarding the link between human demographics and pet ownership. In several international studies, pet ownership was associated with household demographics including: the presence of children in the household, urban/rural location, level of education and age/family structure. What is lacking across all these studies, however, is an understanding of how these pets are spatially distributed throughout the regions under study. This paper describes the spatial distribution of pet dog and pet cat owning households on the island of Ireland. Results In 2006, there were an estimated 640,620 pet dog owning households and 215,542 pet cat owning households in Ireland. These estimates are derived from logistic regression modelling, based on household composition to determine pet dog ownership and the type of house to determine pet cat ownership. Results are presented using chloropleth maps. There is a higher density of pet dog owning households in the east of Ireland and in the cities than the west of Ireland and rural areas. However, in urban districts there are a lower proportion of households owning pet dogs than in rural districts. There are more households with cats in the urban areas, but the proportion of households with cats is greater in rural areas. Conclusions The difference in spatial distribution of dog ownership is a reflection of a generally higher density of households in the east of Ireland and in major cities. The higher proportion of ownership in the west is understandable given the higher proportion of farmers and rural dwellings in this area. Spatial representation allows us to visualise the impact of human household distribution on the density of both pet dogs and pet cats on the island of Ireland. This information can be used when analysing risk of disease spread, for market research and for instigating veterinary care. PMID:21663606

  2. The spatial distribution of pet dogs and pet cats on the island of Ireland.

    PubMed

    Downes, Martin J; Clegg, Tracy A; Collins, Daniel M; McGrath, Guy; More, Simon J

    2011-06-10

    There is considerable international research regarding the link between human demographics and pet ownership. In several international studies, pet ownership was associated with household demographics including: the presence of children in the household, urban/rural location, level of education and age/family structure. What is lacking across all these studies, however, is an understanding of how these pets are spatially distributed throughout the regions under study. This paper describes the spatial distribution of pet dog and pet cat owning households on the island of Ireland. In 2006, there were an estimated 640,620 pet dog owning households and 215,542 pet cat owning households in Ireland. These estimates are derived from logistic regression modelling, based on household composition to determine pet dog ownership and the type of house to determine pet cat ownership. Results are presented using chloropleth maps. There is a higher density of pet dog owning households in the east of Ireland and in the cities than the west of Ireland and rural areas. However, in urban districts there are a lower proportion of households owning pet dogs than in rural districts. There are more households with cats in the urban areas, but the proportion of households with cats is greater in rural areas. The difference in spatial distribution of dog ownership is a reflection of a generally higher density of households in the east of Ireland and in major cities. The higher proportion of ownership in the west is understandable given the higher proportion of farmers and rural dwellings in this area. Spatial representation allows us to visualise the impact of human household distribution on the density of both pet dogs and pet cats on the island of Ireland. This information can be used when analysing risk of disease spread, for market research and for instigating veterinary care.

  3. Correlation between Standardized Uptake Value of 68Ga-DOTA-NOC Positron Emission Tomography/Computed Tomography and Pathological Classification of Neuroendocrine Tumors.

    PubMed

    Kaewput, Chalermrat; Suppiah, Subapriya; Vinjamuri, Sobhan

    2018-01-01

    The aim of our study was to correlate tumor uptake of 68 Ga-DOTA-NOC positron emission tomography/computed tomography (PET/CT) with the pathological grade of neuroendocrine tumors (NETs). 68 Ga-DOTA-NOC PET/CT examinations in 41 patients with histopathologically proven NETs were included in the study. Maximum standardized uptake value (SUV max ) and averaged SUV SUV mean of "main tumor lesions" were calculated for quantitative analyses after background subtraction. Uptake on main tumor lesions was compared and correlated with the tumor histological grade based on Ki-67 index and pathological differentiation. Classification was performed into three grades according to Ki-67 levels; low grade: Ki-67 <2, intermediate grade: Ki-67 3-20, and high grade: Ki-67 >20. Pathological differentiation was graded into well- and poorly differentiated groups. The values were compared and evaluated for correlation and agreement between the two parameters was performed. Our study revealed negatively fair agreement between SUV max of tumor and Ki-67 index ( r = -0.241) and negatively poor agreement between SUV mean of tumor and Ki-67 index ( r = -0.094). SUV max of low-grade, intermediate-grade, and high-grade Ki-67 index is 26.18 ± 14.56, 30.71 ± 24.44, and 6.60 ± 4.59, respectively. Meanwhile, SUV mean of low-grade, intermediate-grade, and high-grade Ki-67 is 8.92 ± 7.15, 9.09 ± 5.18, and 3.00 ± 1.38, respectively. As expected, there was statistically significant decreased SUV max and SUV mean in high-grade tumors (poorly differentiated NETs) as compared with low- and intermediate-grade tumors (well-differentiated NETs). SUV of 68 Ga-DOTA-NOC PET/CT is not correlated with histological grade of NETs. However, there was statistically significant decreased tumor uptake of 68 Ga-DOTA-NOC in poorly differentiated NETs as compared with the well-differentiated group. As a result of this pilot study, we confirm that the lower tumor uptake of 68 Ga-DOTA-NOC may be associated with aggressive behavior and may, therefore, result in poor prognosis.

  4. FDG-PET response of skeletal (bone marrow and bone) involvement after induction chemotherapy in pediatric Hodgkin lymphoma - Are specific response criteria required?

    PubMed

    Georgi, Thomas Walter; Kluge, Regine; Kurch, Lars; Chavdarova, Lidia; Hasenclever, Dirk; Stoevesandt, Dietrich; Pelz, Tanja; Landman-Parker, Judith; Wallace, Hamish; Karlen, Jonas; Fernandez-Teijeiro, Ana; Cepelova, Michaela; Fossa, Alexander; Balwierz, Walentyna; Attarbaschi, Andishe; Ammann, Roland A; Pears, Jane; Hraskova, Andrea; Uyttebroeck, Anne; Beishuizen, Auke; Dieckmann, Karin; Leblanc, Thierry; Daw, Stephen; Baumann, Julia; Körholz, Dieter; Sabri, Osama; Mauz-Körholz, Christine

    2018-04-13

    Purpose: This study focused on skeletal involvement in FDG-PET (PET) in Hodgkin lymphoma (HL). We aimed at a systematic evaluation of the different types of skeletal involvement and their PET response after two cycles of chemotherapy (PET-2), to answer the question whether the current PET response criterion for skeletal involvement is suitable. A secondary objective was to observe the influence of initial uptake intensity and metabolic tumor volume (MTV) of skeletal lesions on the PET-2 response. Methods: Initial PET scans (PET-0) of 1068 pediatric HL patients from the EuroNet-PHL-C1 (C1) trial were evaluated by central review for skeletal involvement. Three types of skeletal lesions were distinguished: skeletal lesions detected only in PET (PETonly), bone marrow (BM) lesions confirmed by MRI or BM biopsy and bone lesions. Uptake intensity (measured as qPET value) and MTV were calculated for each skeletal lesion. All PET-2 scans were assessed for residual tumor activity. The rates of complete metabolic response in PET-2 of skeletal and nodal involvement were compared. Results: 139/1068 (13%) C1 patients showed skeletal involvement (44/139 PETonly patients, 32/139 BM patients and 63/139 bone patients). 101/139 (73%) patients became PET-2 negative in the skeleton while lymph node involvement was PET-2 negative in 94/139 (68%) patients. Highest skeletal PET-2 negative rate was seen in 42/44 (95%) PETonly patients, followed by 22/32 (69%) BM patients and 37/63 (59%) bone patients. Skeletal lesions who became PET-2 negative showed lower median values for initial qPET (2.74) and MTV (2ml) than lesions who remained PET-2 positive (3.84; 7ml). Conclusion: In this study with pediatric HL patients, the complete response rate in PET-2 of skeletal and nodal involvement was similar. Bone flare seemed to be irrelevant. Overall, the current skeletal PET response criterion - comparison with the local skeletal background - is well suited. Initial uptake intensity and MTV of skeletal lesions were predictive for the PET-2 result. Higher values for both parameters were associated with a worse PET-2 response. Copyright © 2018 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  5. How to design PET experiments to study neurochemistry: application to alcoholism.

    PubMed

    Morris, Evan D; Lucas, Molly V; Petrulli, J Ryan; Cosgrove, Kelly P

    2014-03-01

    Positron Emission Tomography (PET) (and the related Single Photon Emission Computed Tomography) is a powerful imaging tool with a molecular specificity and sensitivity that are unique among imaging modalities. PET excels in the study of neurochemistry in three ways: 1) It can detect and quantify neuroreceptor molecules; 2) it can detect and quantify changes in neurotransmitters; and 3) it can detect and quantify exogenous drugs delivered to the brain. To carry out any of these applications, the user must harness the power of kinetic modeling. Further, the quality of the information gained is only as good as the soundness of the experimental design. This article reviews the concepts behind the three main uses of PET, the rationale behind kinetic modeling of PET data, and some of the key considerations when planning a PET experiment. Finally, some examples of PET imaging related to the study of alcoholism are discussed and critiqued.

  6. How to Design PET Experiments to Study Neurochemistry: Application to Alcoholism

    PubMed Central

    Morris, Evan D.; Lucas, Molly V.; Petrulli, J. Ryan; Cosgrove, Kelly P.

    2014-01-01

    Positron Emission Tomography (PET) (and the related Single Photon Emission Computed Tomography) is a powerful imaging tool with a molecular specificity and sensitivity that are unique among imaging modalities. PET excels in the study of neurochemistry in three ways: 1) It can detect and quantify neuroreceptor molecules; 2) it can detect and quantify changes in neurotransmitters; and 3) it can detect and quantify exogenous drugs delivered to the brain. To carry out any of these applications, the user must harness the power of kinetic modeling. Further, the quality of the information gained is only as good as the soundness of the experimental design. This article reviews the concepts behind the three main uses of PET, the rationale behind kinetic modeling of PET data, and some of the key considerations when planning a PET experiment. Finally, some examples of PET imaging related to the study of alcoholism are discussed and critiqued. PMID:24600335

  7. [The elderly and their pets. Supportive and problematic aspects and implications for care. A descriptive study].

    PubMed

    Graf, S

    1999-04-01

    Pet ownership by elderly people is very common. This phenomenological study investigated why elderly people keep pets and what illness of the animals or their loss means to them. Nine women and three men owning either cats, dogs, or birds participated in this study. Their average age was 84. The results confirm on the one hand that elderly people experience happiness and joy thanks to having pets, giving them an ingenious social function as well as helping overcome the frequent passivity of old age. The problems arising with the ownership of animals are accident endangering (falls) and overexertion. An additional concern is the support of the animals during illness of the owner. The loss of animals is often connected with serious grief reaction and disorganisation of daily life. Serious, long-lasting, and pathological grief reactions were shown after a forced separation from the pet. Four recommendations for nursing practice resulted from this study: to approve and support the ownership of pets and domestic animals as a factor of the "good old age"; to accept the pets as part of the 'family' and integrate them into nursing work, to encourage the owner to plan the future of the pet. Finally, to help overcome the loss of pets and animals a specific nursing therapeutic treatment is required.

  8. Comparison Between 64Cu-PSMA-617 PET/CT and 18F-Choline PET/CT Imaging in Early Diagnosis of Prostate Cancer Biochemical Recurrence.

    PubMed

    Cantiello, Francesco; Crocerossa, Fabio; Russo, Giorgio Ivan; Gangemi, Vincenzo; Ferro, Matteo; Vartolomei, Mihai Dorin; Lucarelli, Giuseppe; Mirabelli, Maria; Scafuro, Chiara; Ucciero, Giuseppe; De Cobelli, Ottavio; Morgia, Giuseppe; Damiano, Rocco; Cascini, Giuseppe Lucio

    2018-06-04

    To evaluate the diagnostic performance of 64 Cu-PSMA-617 positron emission tomography (PET) with computed tomography (CT) for restaging prostate cancer after biochemical recurrence (BCR) and to compare it with 18 F-choline PET/CT in a per-patient analysis. An observational study was performed of 43 patients with BCR after laparoscopic radical prostatectomy who underwent 64 Cu-PSMA-617 PET/CT and subsequently 18 F-choline PET/CT for restaging. The detection rates (DR) of 64 Cu-PSMA-617 PET/CT and of 18 F-choline PET/CT were calculated by standardized maximum uptake value (SUV max ) at 4 hours and SUV max at 1 hour as reference, respectively. Furthermore, univariate logistic regression analysis was carried out to identify independent predictive factors of positivity with 64 Cu-PSMA-617 PET/CT. An overall positivity with 64 Cu-PSMA-617 PET/CT was found in 32 patients (74.4%) versus 19 (44.2%) with 18 F-choline PET/CT. Specifically, after stratifying for prostate-specific antigen (PSA) values, we found a good performance of 64 Cu-PSMA-617 PET/CT at low PSA levels compared to 18 F-choline PET/CT, with a DR of 57.1% versus 14.3% for PSA 0.2-0.5 ng/mL (P = .031), and of 60% versus 30% with PSA 0.5-1 ng/mL. At univariate binary logistic regression analysis, PSA level was the only independent predictor of 64 Cu-PSMA-617 PET/CT positivity. No significant difference in terms of DR for both 64 Cu-PSMA-617 PET/CT and 18 F-choline PET/CT was found according to different Gleason score subgroups. In our study cohort, a better performance was observed for 64 Cu-PSMA-617 PET/CT compared to 18 F-choline PET/CT in restaging after BCR, especially in patients with low PSA values. Copyright © 2018 Elsevier Inc. All rights reserved.

  9. Does the Teacher's Pet Phenomenon Inevitably Cause Classroom Conflict? Comparative Viewpoints of Three Pet-Student Groups

    ERIC Educational Resources Information Center

    Chiu, Shao-I; Lee, Jiezhi; Liang, Tsanglang

    2013-01-01

    Although most studies reveal a relationship between the teacher's pet phenomenon with classroom conflict, it does not necessarily cause classroom conflict. This study confirms the model fit for teacher authority, the existence of the teacher's pet phenomenon and its relationship to classroom conflict and students' self-adjustment, as well as…

  10. Older Latinos, pets, and health.

    PubMed

    Johnson, Rebecca A; Meadows, Richard L

    2002-10-01

    The majority of thefindings regarding pet ownership, interaction, and the human-animal bond have involved only Caucasians or have included other ethnic group members only incidentally. The extent to which older adultsfrom other ethnic groups may benefitfrom pet ownership and interaction is unclear. If the benefits of human-animal interaction are to be used effectively in promoting health and preventing illness, it is necessary to identify the "boundaries" of effectiveness for this interaction across various populations. The present study is an initial effort at describing one ethnic minority group, Latino pet owners, the extent of their relationships with their pet, and the extent to which these relationships may be beneficial in facilitating health. Twenty-four Latinos over age 50 were studied and are described in terms of their demographic characteristics, relationships with their pets, health, and exercise practices. The findings suggest that the participants were very devoted to their pets, had been involved with pets since childhood, and viewed themselves as healthy.

  11. Stray animals: their impact on a community.

    PubMed

    Griffiths, A O; Silberberg, A

    1975-04-01

    The statistical import of the study not-withstanding, we found the most serious problem to be the lack of understanding of the pet population crisis and compassion toward animals on the part of pet owners, as evident in the pet columns of the classified ads. Our study leads us to believe that pet owners are allowing the reproduction of kittens and puppies in such numbers that they often have no cash value and, in fact, the owners will spend money, in the form of advertising, to facilitate their disposal. The street observations indicated that relatively few animals (lessthan 1%) actually are allowed to run free. Dog bites occur at a ratio of 1:20 for the dog population. In the area under study, free roaming dogs and cats present a mild to moderate problem, originating from a small percentage of pet owners. Only a small amount of pet animal suffering occurs by death from environmental hazards (ie, automobiles), and there is just a moderate amount of intentional killing of nondersirable pet animals. We fell the method used in this study and the results obtained from it have importance elsewhere. It should be coupled with a broader based survey questionnaire to better establish the ratio of pet ownership to the general population and the reasons and benefits of pet ownership. We could then have the "facts" about the pet overpopulation problem, as well as better understand the community values toward pet animals. A complete report with additional accompanying tables is available from the senior author at Rural Route One, Urbana, Illinois 61801.

  12. Critters in the cube farm: perceived psychological and organizational effects of pets in the workplace.

    PubMed

    Wells, M; Perrine, R

    2001-01-01

    This article reports the findings of an exploratory study examining the perceived functions and psychological and organizational effects of pets in the workplace. Participants were 193 employees from 31 companies allowing pets in the workplace who completed anonymous questionnaires. Results indicated that participants perceived pets in the workplace to reduce stress and to positively affect employee health and the organization. Participants who brought their pets to work perceived greater benefits than participants who did not bring their pets to work and participants who did not own pets.

  13. Evaluation of chemotherapy response in patients with advanced head and neck cancer using [F-18]fluorodeoxyglucose positron emission tomography.

    PubMed

    Lowe, V J; Dunphy, F R; Varvares, M; Kim, H; Wittry, M; Dunphy, C H; Dunleavy, T; McDonough, E; Minster, J; Fletcher, J W; Boyd, J H

    1997-12-01

    [F-18]Fluorodeoxyglucose (FDG)-positron emission tomography (PET) can measure the metabolic activity of tissues; FDG-PET may be able to predict response to chemotherapy by identifying changes in tumor metabolism. Measurement of response to treatment may help improve survival in the management of advanced head and neck cancer. We evaluated this particular use of FDG-PET in patients participating in a neoadjuvant organ-preservation protocol using taxol and carboplatin and compared pathologic response after chemotherapy with changes in tumor metabolism measured by FDG-PET. Serial FDG-PET studies (n = 56) were performed in patients (n = 28) with stage III/IV head and neck cancer participating in a neoadjuvant organ-preservation protocol. The FDG-PET studies were performed before and after chemotherapy. All patients had tissue biopsies before and after chemotherapy. Patients were classified as pathologic complete response (PCR) or residual disease (RD) based on tissue biopsies. Visual analysis of PET scans was performed to identify patients with complete response by PET, and these findings were compared with pathology results. Metabolic changes were also evaluated using standardized uptake ratios (SUR) of FDG. The sensitivity and specificity of PET for residual cancer after therapy was 90% (19/21) and 83% (5/6), respectively. Two patients had initially negative biopsies and positive PET studies for persistent disease. Pathology review and rebiospy led to confirmation of the PET results in these cases, giving a sensitivity of 90% for initial tissue biopsy. In this preliminary analysis, FDG-PET was accurate in classifying response to chemotherapy in most patients. Fluorodeoxyglucose-PET may identify residual viable tumor when it is otherwise undetectable.

  14. The value of FDG PET/CT for follow-up of patients with melanoma: a retrospective analysis

    PubMed Central

    Vensby, Philip H; Schmidt, Grethe; Kjær, Andreas; Fischer, Barbara M

    2017-01-01

    The incidence of melanoma (MM) is among the fastest rising cancers in the western countries. Positron Emission Tomography with Computed Tomography (PET/CT) is a valuable non-invasive tool for the diagnosis and staging of patients with MM. However, research on the value of PET/CT in follow-up of melanoma patients is limited. This study assesses the diagnostic value of PET/CT for follow-up after melanoma surgery. This retrospective study includes patients with MM who performed at least one PET/CT scan after initial surgery and staging. PET/CT findings were compared to histology, MRI or fine needle aspiration (FNA) to estimate the diagnostic accuracy. The diagnostic performance of PET/CT performed in patients with and without a clinical suspicion of relapse was compared. 238 patients (526 scans) were included. Of the 526 scans 130 (25%) scans were PET-positive, 365 (69%) PET-negative, and 28 (5%) had equivocal findings. Sensitivity was 89% [0.82-0.94], specificity 92% [0.89-0.95], positive and negative predictive values of 78% [0.70-0.84] and 97% [0.94-0.98] respectively. When stratified for reason of referral there was no statistical significant difference in the diagnostic accuracy of PET/CT between patients referred with or without a clinical suspicion of relapse. This study demonstrates that PET/CT despite a moderate sensitivity has a high negative predictive value in the follow-up of melanoma patients. Thus, a negative PET/CT-scan essentially rules out relapse. However, the frequency of false positive findings is relatively high, especially among patients undergoing a “routine” PET/CT with no clinical suspicion of relapse, potentially causing anxiety and leading to further diagnostic procedures. PMID:29348980

  15. The value of FDG PET/CT for follow-up of patients with melanoma: a retrospective analysis.

    PubMed

    Vensby, Philip H; Schmidt, Grethe; Kjær, Andreas; Fischer, Barbara M

    2017-01-01

    The incidence of melanoma (MM) is among the fastest rising cancers in the western countries. Positron Emission Tomography with Computed Tomography (PET/CT) is a valuable non-invasive tool for the diagnosis and staging of patients with MM. However, research on the value of PET/CT in follow-up of melanoma patients is limited. This study assesses the diagnostic value of PET/CT for follow-up after melanoma surgery. This retrospective study includes patients with MM who performed at least one PET/CT scan after initial surgery and staging. PET/CT findings were compared to histology, MRI or fine needle aspiration (FNA) to estimate the diagnostic accuracy. The diagnostic performance of PET/CT performed in patients with and without a clinical suspicion of relapse was compared. 238 patients (526 scans) were included. Of the 526 scans 130 (25%) scans were PET-positive, 365 (69%) PET-negative, and 28 (5%) had equivocal findings. Sensitivity was 89% [0.82-0.94], specificity 92% [0.89-0.95], positive and negative predictive values of 78% [0.70-0.84] and 97% [0.94-0.98] respectively. When stratified for reason of referral there was no statistical significant difference in the diagnostic accuracy of PET/CT between patients referred with or without a clinical suspicion of relapse. This study demonstrates that PET/CT despite a moderate sensitivity has a high negative predictive value in the follow-up of melanoma patients. Thus, a negative PET/CT-scan essentially rules out relapse. However, the frequency of false positive findings is relatively high, especially among patients undergoing a "routine" PET/CT with no clinical suspicion of relapse, potentially causing anxiety and leading to further diagnostic procedures.

  16. Cardiovascular reactivity and the presence of pets, friends, and spouses: the truth about cats and dogs.

    PubMed

    Allen, Karen; Blascovich, Jim; Mendes, Wendy B

    2002-01-01

    The purpose of this study was to examine the effects of the presence of friends, spouses, and pets on cardiovascular reactivity to psychological and physical stress. Cardiovascular reactivity was examined among 240 married couples, half of whom owned a pet. Mental arithmetic and cold pressor were performed in one of four randomly assigned social support conditions: alone, with pet or friend (friend present for non-pet owners), with spouse, with spouse and pet/friend. Relative to people without pets, people with pets had significantly lower heart rate and blood pressure levels during a resting baseline, significantly smaller increases (ie, reactivity) from baseline levels during the mental arithmetic and cold pressor, and faster recovery. Among pet owners, the lowest reactivity and quickest recovery was observed in the pet-present conditions. People perceive pets as important, supportive parts of their lives, and significant cardiovascular and behavioral benefits are associated with those perceptions.

  17. Comparative characteristics of quantitative indexes for 18F-FDG uptake and metabolic volume in sequentially obtained PET/MRI and PET/CT.

    PubMed

    Lee, Soo Jin; Paeng, Jin Chul; Goo, Jin Mo; Lee, Jeong Min; Cheon, Gi Jeong; Lee, Dong Soo; Chung, June-Key; Kang, Keon Wook

    2017-04-01

    The purpose of this study was to compare quantitative indexes for fluorine-18 fluorodeoxyglucose uptake and metabolic volume between PET/MRI and PET/CT. Sixty-six patients with solid tumors (32 with lung cancer and 34 with pancreatic cancer) who underwent sequential fluorine-18 fluorodeoxyglucose PET/MRI and PET/CT were retrospectively enrolled. On PET images, maximum and peak standardized uptake values (SUVmax and SUVpeak, respectively), and maximum tumor-to-liver ratio (TLRmax) were measured. Metabolic tumor volume (MTV) and total-lesion glycolysis (TLG) with margin thresholds of 50% SUVmax and SUV 2.5 (MTV50%, MTV2.5; TLG50%, TLG2.5, respectively) were compared between PET/MRI and PET/CT, with patients classified into two groups using imaging protocol (the PET/MRI-first and PET/CT-first groups). There were significant correlations of all tested indexes between PET/MRI and PET/CT (r=0.867-0.987, P<0.001). SUVmax and SUVpeak were lower on PET/MRI regardless of imaging protocol (P<0.001 in the PET/MRI-first group). In contrast, TLRmax exhibited reverse results between the PET/MRI-first and PET/CT-first groups. MTV50% and TLG values varied between PET/MRI and PET/CT, as well as between the PET/MRI-first and PET/CT-first groups. However, MTV2.5 was relatively robust against imaging protocol and modality. There are significant correlations of the quantitative indexes between PET/MRI and PET/CT. However, uptake indexes of SUVmax and SUVpeak are lower on PET/MRI than on PET/CT, and volumetric indexes of MTV50% and TLG values also exhibited significant differences. It may be suggested that TLRmax and MTV2.5 are relatively more appropriate indexes than others when PET/MRI and PET/CT are used interchangeably.

  18. MRI-assisted PET motion correction for neurologic studies in an integrated MR-PET scanner.

    PubMed

    Catana, Ciprian; Benner, Thomas; van der Kouwe, Andre; Byars, Larry; Hamm, Michael; Chonde, Daniel B; Michel, Christian J; El Fakhri, Georges; Schmand, Matthias; Sorensen, A Gregory

    2011-01-01

    Head motion is difficult to avoid in long PET studies, degrading the image quality and offsetting the benefit of using a high-resolution scanner. As a potential solution in an integrated MR-PET scanner, the simultaneously acquired MRI data can be used for motion tracking. In this work, a novel algorithm for data processing and rigid-body motion correction (MC) for the MRI-compatible BrainPET prototype scanner is described, and proof-of-principle phantom and human studies are presented. To account for motion, the PET prompt and random coincidences and sensitivity data for postnormalization were processed in the line-of-response (LOR) space according to the MRI-derived motion estimates. The processing time on the standard BrainPET workstation is approximately 16 s for each motion estimate. After rebinning in the sinogram space, the motion corrected data were summed, and the PET volume was reconstructed using the attenuation and scatter sinograms in the reference position. The accuracy of the MC algorithm was first tested using a Hoffman phantom. Next, human volunteer studies were performed, and motion estimates were obtained using 2 high-temporal-resolution MRI-based motion-tracking techniques. After accounting for the misalignment between the 2 scanners, perfectly coregistered MRI and PET volumes were reproducibly obtained. The MRI output gates inserted into the PET list-mode allow the temporal correlation of the 2 datasets within 0.2 ms. The Hoffman phantom volume reconstructed by processing the PET data in the LOR space was similar to the one obtained by processing the data using the standard methods and applying the MC in the image space, demonstrating the quantitative accuracy of the procedure. In human volunteer studies, motion estimates were obtained from echo planar imaging and cloverleaf navigator sequences every 3 s and 20 ms, respectively. Motion-deblurred PET images, with excellent delineation of specific brain structures, were obtained using these 2 MRI-based estimates. An MRI-based MC algorithm was implemented for an integrated MR-PET scanner. High-temporal-resolution MRI-derived motion estimates (obtained while simultaneously acquiring anatomic or functional MRI data) can be used for PET MC. An MRI-based MC method has the potential to improve PET image quality, increasing its reliability, reproducibility, and quantitative accuracy, and to benefit many neurologic applications.

  19. Diagnostic value of [(18)F]-FDG PET/CT in children with fever of unknown origin or unexplained signs of inflammation.

    PubMed

    Jasper, Niklas; Däbritz, Jan; Frosch, Michael; Loeffler, Markus; Weckesser, Matthias; Foell, Dirk

    2010-01-01

    Fever of unknown origin (FUO) and unexplained signs of inflammation are challenging medical problems especially in children and predominantly caused by infections, malignancies or noninfectious inflammatory diseases. The aim of this study was to assess the diagnostic value of (18)F-FDG PET and PET/CT in the diagnostic work-up in paediatric patients. In this retrospective study, 47 FDG PET and 30 PET/CT scans from 69 children (median age 8.1 years, range 0.2-18.1 years, 36 male, 33 female) were analysed. The diagnostic value of PET investigations in paediatric patients presenting with FUO (44 scans) or unexplained signs of inflammation without fever (33 scans) was analysed. A diagnosis in paediatric patients with FUO or unexplained signs of inflammation could be established in 32 patients (54%). Of all scans, 63 (82%) were abnormal, and of the total number of 77 PET and PET/CT scans 35 (45%) were clinically helpful. In patients with a final diagnosis, scans were found to have contributed to the diagnosis in 73%. Laboratory, demographic or clinical parameters of the children did not predict the usefulness of FDG PET scans. This is the first larger study demonstrating that FDG PET and PET/CT may be valuable diagnostic tools for the evaluation of children with FUO and unexplained signs of inflammation. Depicting inflammation in the whole body, while not being traumatic, it is attractive for use especially in children. The combination of PET with CT seems to be superior, since the site of inflammation can be localized more accurately.

  20. Cloning, production, and purification of proteins for a medium-scale structural genomics project.

    PubMed

    Quevillon-Cheruel, Sophie; Collinet, Bruno; Trésaugues, Lionel; Minard, Philippe; Henckes, Gilles; Aufrère, Robert; Blondeau, Karine; Zhou, Cong-Zhao; Liger, Dominique; Bettache, Nabila; Poupon, Anne; Aboulfath, Ilham; Leulliot, Nicolas; Janin, Joël; van Tilbeurgh, Herman

    2007-01-01

    The South-Paris Yeast Structural Genomics Pilot Project (http://www.genomics.eu.org) aims at systematically expressing, purifying, and determining the three-dimensional structures of Saccharomyces cerevisiae proteins. We have already cloned 240 yeast open reading frames in the Escherichia coli pET system. Eighty-two percent of the targets can be expressed in E. coli, and 61% yield soluble protein. We have currently purified 58 proteins. Twelve X-ray structures have been solved, six are in progress, and six other proteins gave crystals. In this chapter, we present the general experimental flowchart applied for this project. One of the main difficulties encountered in this pilot project was the low solubility of a great number of target proteins. We have developed parallel strategies to recover these proteins from inclusion bodies, including refolding, coexpression with chaperones, and an in vitro expression system. A limited proteolysis protocol, developed to localize flexible regions in proteins that could hinder crystallization, is also described.

  1. Simultaneous whole body 18F-fluorodeoxyglucose positron emission tomography magnetic resonance imaging for evaluation of pediatric cancer: Preliminary experience and comparison with 18F-fluorodeoxyglucose positron emission tomography computed tomography

    PubMed Central

    Pugmire, Brian S; Guimaraes, Alexander R; Lim, Ruth; Friedmann, Alison M; Huang, Mary; Ebb, David; Weinstein, Howard; Catalano, Onofrio A; Mahmood, Umar; Catana, Ciprian; Gee, Michael S

    2016-01-01

    AIM: To describe our preliminary experience with simultaneous whole body 18F-fluorodeoxyglucose (18F-FDG) positron emission tomography and magnetic resonance imaging (PET-MRI) in the evaluation of pediatric oncology patients. METHODS: This prospective, observational, single-center study was Health Insurance Portability and Accountability Act-compliant, and institutional review board approved. To be eligible, a patient was required to: (1) have a known or suspected cancer diagnosis; (2) be under the care of a pediatric hematologist/oncologist; and (3) be scheduled for clinically indicated 18F-FDG positron emission tomography-computed tomography (PET-CT) examination at our institution. Patients underwent PET-CT followed by PET-MRI on the same day. PET-CT examinations were performed using standard department protocols. PET-MRI studies were acquired with an integrated 3 Tesla PET-MRI scanner using whole body T1 Dixon, T2 HASTE, EPI diffusion-weighted imaging (DWI) and STIR sequences. No additional radiotracer was given for the PET-MRI examination. Both PET-CT and PET-MRI examinations were reviewed by consensus by two study personnel. Test performance characteristics of PET-MRI, for the detection of malignant lesions, including FDG maximum standardized uptake value (SUVmax) and minimum apparent diffusion coefficient (ADCmin), were calculated on a per lesion basis using PET-CT as a reference standard. RESULTS: A total of 10 whole body PET-MRI exams were performed in 7 pediatric oncology patients. The mean patient age was 16.1 years (range 12-19 years) including 6 males and 1 female. A total of 20 malignant and 21 benign lesions were identified on PET-CT. PET-MRI SUVmax had excellent correlation with PET-CT SUVmax for both benign and malignant lesions (R = 0.93). PET-MRI SUVmax > 2.5 had 100% accuracy for discriminating benign from malignant lesions using PET-CT reference. Whole body DWI was also evaluated: the mean ADCmin of malignant lesions (780.2 + 326.6) was significantly lower than that of benign lesions (1246.2 + 417.3; P = 0.0003; Student’s t test). A range of ADCmin thresholds for malignancy were evaluated, from 0.5-1.5 × 10-3 mm2/s. The 1.0 × 10-3 ADCmin threshold performed best compared with PET-CT reference (68.3% accuracy). However, the accuracy of PET-MRI SUVmax was significantly better than ADCmin for detecting malignant lesions compared with PET-CT reference (P < 0.0001; two-tailed McNemar’s test). CONCLUSION: These results suggest a clinical role for simultaneous whole body PET-MRI in evaluating pediatric cancer patients. PMID:27028112

  2. Simultaneous whole body (18)F-fluorodeoxyglucose positron emission tomography magnetic resonance imaging for evaluation of pediatric cancer: Preliminary experience and comparison with (18)F-fluorodeoxyglucose positron emission tomography computed tomography.

    PubMed

    Pugmire, Brian S; Guimaraes, Alexander R; Lim, Ruth; Friedmann, Alison M; Huang, Mary; Ebb, David; Weinstein, Howard; Catalano, Onofrio A; Mahmood, Umar; Catana, Ciprian; Gee, Michael S

    2016-03-28

    To describe our preliminary experience with simultaneous whole body (18)F-fluorodeoxyglucose ((18)F-FDG) positron emission tomography and magnetic resonance imaging (PET-MRI) in the evaluation of pediatric oncology patients. This prospective, observational, single-center study was Health Insurance Portability and Accountability Act-compliant, and institutional review board approved. To be eligible, a patient was required to: (1) have a known or suspected cancer diagnosis; (2) be under the care of a pediatric hematologist/oncologist; and (3) be scheduled for clinically indicated (18)F-FDG positron emission tomography-computed tomography (PET-CT) examination at our institution. Patients underwent PET-CT followed by PET-MRI on the same day. PET-CT examinations were performed using standard department protocols. PET-MRI studies were acquired with an integrated 3 Tesla PET-MRI scanner using whole body T1 Dixon, T2 HASTE, EPI diffusion-weighted imaging (DWI) and STIR sequences. No additional radiotracer was given for the PET-MRI examination. Both PET-CT and PET-MRI examinations were reviewed by consensus by two study personnel. Test performance characteristics of PET-MRI, for the detection of malignant lesions, including FDG maximum standardized uptake value (SUVmax) and minimum apparent diffusion coefficient (ADCmin), were calculated on a per lesion basis using PET-CT as a reference standard. A total of 10 whole body PET-MRI exams were performed in 7 pediatric oncology patients. The mean patient age was 16.1 years (range 12-19 years) including 6 males and 1 female. A total of 20 malignant and 21 benign lesions were identified on PET-CT. PET-MRI SUVmax had excellent correlation with PET-CT SUVmax for both benign and malignant lesions (R = 0.93). PET-MRI SUVmax > 2.5 had 100% accuracy for discriminating benign from malignant lesions using PET-CT reference. Whole body DWI was also evaluated: the mean ADCmin of malignant lesions (780.2 + 326.6) was significantly lower than that of benign lesions (1246.2 + 417.3; P = 0.0003; Student's t test). A range of ADCmin thresholds for malignancy were evaluated, from 0.5-1.5 × 10(-3) mm(2)/s. The 1.0 × 10(-3) ADCmin threshold performed best compared with PET-CT reference (68.3% accuracy). However, the accuracy of PET-MRI SUVmax was significantly better than ADCmin for detecting malignant lesions compared with PET-CT reference (P < 0.0001; two-tailed McNemar's test). These results suggest a clinical role for simultaneous whole body PET-MRI in evaluating pediatric cancer patients.

  3. Metabolic imaging biomarkers of postradiotherapy xerostomia.

    PubMed

    Cannon, Blake; Schwartz, David L; Dong, Lei

    2012-08-01

    Xerostomia is a major complication of head and neck radiotherapy (RT). Available xerostomia measures remain flawed. [(18)F]fluorodeoxyglucose-labeled positron emission tomography-computed tomography (FDG-PET-CT) is routinely used for staging and response assessment of head and neck cancer. We investigated quantitative measurement of parotid gland FDG uptake as a potential biomarker for post-RT xerostomia. Ninety-eight locally advanced head and neck cancer patients receiving definitive RT underwent baseline and post-RT FDG-PET-CT on a prospective imaging trial. A separate validation cohort of 14 patients underwent identical imaging while prospectively enrolled in a second trial collecting sialometry and patient-reported outcomes. Radiation dose and pre- and post-RT standard uptake values (SUVs) for all voxels contained within parotid gland ROI were deformably registered. Average whole-gland or voxel-by-voxel models incorporating parotid D(Met) (defined as the pretreatment parotid SUV weighted by dose) accurately predicted posttreatment changes in parotid FDG uptake (e.g., fractional parotid SUV). Fractional loss of parotid FDG uptake closely paralleled early parotid toxicity defined by posttreatment salivary output (p < 0.01) and Radiation Therapy Oncology Group/European Organization for Research and Treatment of Cancer xerostomia scores (p < 0.01). In this pilot series, loss of parotid FDG uptake was strongly associated with acute clinical post-RT parotid toxicity. D(Met) may potentially be used to guide function-sparing treatment planning. Prospective validation of FDG-PET-CT as a convenient, quantifiable imaging biomarker of parotid function is warranted and ongoing. Copyright © 2012 Elsevier Inc. All rights reserved.

  4. Human-animal interaction as a social determinant of health: descriptive findings from the health and retirement study.

    PubMed

    Mueller, Megan K; Gee, Nancy R; Bures, Regina M

    2018-03-09

    We focused on human-animal interaction (HAI) as an important aspect of social functioning at the individual level, framing this emerging field from a public health perspective. Using data from the Health and Retirement Study (HRS) 2012 HAI module, we describe the characteristics of pet ownership in a population of older adults, and examine the relation between pet ownership and multiple mental and physical health indicators such as health status, depression, and physical activity. Of the 1657 participants in our subsample, approximately half (51.5%) reported being pet owners; the majority owned dogs or cats, and most had only one pet. Pet ownership was significantly associated with a higher likelihood of ever having had depression, with pet owners being 1.89 times more likely to have experienced depression. However, pet ownership was not associated with having experienced depression within the last week. The findings from this study could indicate a relationship between pet ownership and depression, but it is impossible to determine the directionality of that relationship. It is possible that owning a pet may put a person at an increased risk of developing depression, or individuals who are at risk, or who have already developed depression, may acquire a pet as a way of managing their depressive symptoms. The findings of this study provide an initial step in contributing to our understanding of the relationship between companion animals and the social, physical, and mental well-being of the HRS study population. Future research should include measures of HAI in longitudinal, population-based surveys.

  5. Textural features and SUV-based variables assessed by dual time point 18F-FDG PET/CT in locally advanced breast cancer.

    PubMed

    Garcia-Vicente, Ana María; Molina, David; Pérez-Beteta, Julián; Amo-Salas, Mariano; Martínez-González, Alicia; Bueno, Gloria; Tello-Galán, María Jesús; Soriano-Castrejón, Ángel

    2017-12-01

    To study the influence of dual time point 18F-FDG PET/CT in textural features and SUV-based variables and their relation among them. Fifty-six patients with locally advanced breast cancer (LABC) were prospectively included. All of them underwent a standard 18F-FDG PET/CT (PET-1) and a delayed acquisition (PET-2). After segmentation, SUV variables (SUVmax, SUVmean, and SUVpeak), metabolic tumor volume (MTV), and total lesion glycolysis (TLG) were obtained. Eighteen three-dimensional (3D) textural measures were computed including: run-length matrices (RLM) features, co-occurrence matrices (CM) features, and energies. Differences between all PET-derived variables obtained in PET-1 and PET-2 were studied. Significant differences were found between the SUV-based parameters and MTV obtained in the dual time point PET/CT, with higher values of SUV-based variables and lower MTV in the PET-2 with respect to the PET-1. In relation with the textural parameters obtained in dual time point acquisition, significant differences were found for the short run emphasis, low gray-level run emphasis, short run high gray-level emphasis, run percentage, long run emphasis, gray-level non-uniformity, homogeneity, and dissimilarity. Textural variables showed relations with MTV and TLG. Significant differences of textural features were found in dual time point 18F-FDG PET/CT. Thus, a dynamic behavior of metabolic characteristics should be expected, with higher heterogeneity in delayed PET acquisition compared with the standard PET. A greater heterogeneity was found in bigger tumors.

  6. The Role of Fluorine-18-Fluorodeoxyglucose Positron Emission Tomography in Aggressive Histological Subtypes of Thyroid Cancer: An Overview

    PubMed Central

    Treglia, Giorgio; Annunziata, Salvatore; Muoio, Barbara; Salvatori, Massimo; Ceriani, Luca; Giovanella, Luca

    2013-01-01

    Aggressive histological subtypes of thyroid cancer are rare and have a poor prognosis. The most important aggressive subtypes of thyroid cancer are Hürthle cell carcinoma (HCTC) and anaplastic and poorly differentiated carcinoma (ATC and PDTC). The American Thyroid Association recently published guidelines for the management of patients with ATC, but no specific guidelines have been done about HCTC. We performed an overview of the literature about the role of Fluorine-18-Fluorodeoxyglucose positron emission tomography or positron emission tomography/computed tomography (FDG-PET or PET/CT) in aggressive histological subtypes of thyroid cancer. Only few original studies about the role of FDG-PET or PET/CT in HCTC, PDTC, and ATC have been published in the literature. FDG-PET or PET/CT seems to be useful in staging or followup of invasive and metastatic HCTC. FDG-PET or PET/CT should be used in patients with ATC in initial staging and in the followup after surgery to evaluate metastatic disease. Some authors suggest the use of FDG-PET/CT in staging of PDTC, but more studies are needed to define the diagnostic use of FDG-PET/CT in this setting. Limited experience suggests the usefulness of FDG-PET or PET/CT in patients with more aggressive histological subtypes of DTC. However, DTC presenting as radioiodine refractory and FDG-PET positive should be considered aggressive tumours with poor prognosis. PMID:23653645

  7. A Systematic Review and Aggregated Analysis on the Impact of Amyloid PET Brain Imaging on the Diagnosis, Diagnostic Confidence, and Management of Patients being Evaluated for Alzheimer's Disease.

    PubMed

    Fantoni, Enrico R; Chalkidou, Anastasia; O' Brien, John T; Farrar, Gill; Hammers, Alexander

    2018-01-01

    Amyloid PET (aPET) imaging could improve patient outcomes in clinical practice, but the extent of impact needs quantification. To provide an aggregated quantitative analysis of the value added by aPET in cognitively impaired subjects. Systematic literature searches were performed in Embase and Medline until January 2017. 1,531 cases over 12 studies were included (1,142 cases over seven studies in the primary analysis where aPET was the key biomarker; the remaining cases included as defined groups in the secondary analysis). Data was abstracted by consensus among two observers and assessed for bias. Clinical utility was measured by diagnostic change, diagnostic confidence, and patient management before and after aPET. Three groups were further analyzed: control patients for whom feedback of aPET scan results was delayed; aPET Appropriate Use Criteria (AUC+) cases; and patients undergoing additional FDG/CSF testing. For 1,142 cases with only aPET, 31.3% of diagnoses were revised, whereas 3.2% of diagnoses changed in the delayed aPET control group (p < 0.0001). Increased diagnostic confidence following aPET was found for 62.1% of 870 patients. Management changes with aPET were found in 72.2% of 740 cases and in 55.5% of 299 cases in the control group (p < 0.0001). The diagnostic value of aPET in AUC+ patients or when FDG/CSF were additionally available did not substantially differ from the value of aPET alone in the wider population. Amyloid PET contributed to diagnostic revision in almost a third of cases and demonstrated value in increasing diagnostic confidence and refining management plans.

  8. A Systematic Review and Aggregated Analysis on the Impact of Amyloid PET Brain Imaging on the Diagnosis, Diagnostic Confidence, and Management of Patients being Evaluated for Alzheimer’s Disease

    PubMed Central

    Fantoni, Enrico R.; Chalkidou, Anastasia; O’ Brien, John T.; Farrar, Gill; Hammers, Alexander

    2018-01-01

    Background: Amyloid PET (aPET) imaging could improve patient outcomes in clinical practice, but the extent of impact needs quantification. Objective: To provide an aggregated quantitative analysis of the value added by aPET in cognitively impaired subjects. Methods: Systematic literature searches were performed in Embase and Medline until January 2017. 1,531 cases over 12 studies were included (1,142 cases over seven studies in the primary analysis where aPET was the key biomarker; the remaining cases included as defined groups in the secondary analysis). Data was abstracted by consensus among two observers and assessed for bias. Clinical utility was measured by diagnostic change, diagnostic confidence, and patient management before and after aPET. Three groups were further analyzed: control patients for whom feedback of aPET scan results was delayed; aPET Appropriate Use Criteria (AUC+) cases; and patients undergoing additional FDG/CSF testing. Results: For 1,142 cases with only aPET, 31.3% of diagnoses were revised, whereas 3.2% of diagnoses changed in the delayed aPET control group (p < 0.0001). Increased diagnostic confidence following aPET was found for 62.1% of 870 patients. Management changes with aPET were found in 72.2% of 740 cases and in 55.5% of 299 cases in the control group (p < 0.0001). The diagnostic value of aPET in AUC+ patients or when FDG/CSF were additionally available did not substantially differ from the value of aPET alone in the wider population. Conclusions: Amyloid PET contributed to diagnostic revision in almost a third of cases and demonstrated value in increasing diagnostic confidence and refining management plans. PMID:29689725

  9. Comparison of first pass bolus AIFs extracted from sequential 18F-FDG PET and DSC-MRI of mice

    NASA Astrophysics Data System (ADS)

    Evans, Eleanor; Sawiak, Stephen J.; Ward, Alexander O.; Buonincontri, Guido; Hawkes, Robert C.; Adrian Carpenter, T.

    2014-01-01

    Accurate kinetic modelling of in vivo physiological function using positron emission tomography (PET) requires determination of the tracer time-activity curve in plasma, known as the arterial input function (AIF). The AIF is usually determined by invasive blood sampling methods, which are prohibitive in murine studies due to low total blood volumes. Extracting AIFs from PET images is also challenging due to large partial volume effects (PVE). We hypothesise that in combined PET with magnetic resonance imaging (PET/MR), a co-injected bolus of MR contrast agent and PET ligand can be tracked using fast MR acquisitions. This protocol would allow extraction of a MR AIF from MR contrast agent concentration-time curves, at higher spatial and temporal resolution than an image-derived PET AIF. A conversion factor could then be applied to the MR AIF for use in PET kinetic analysis. This work has compared AIFs obtained from sequential DSC-MRI and PET with separate injections of gadolinium contrast agent and 18F-FDG respectively to ascertain the technique‧s validity. An automated voxel selection algorithm was employed to improve MR AIF reproducibility. We found that MR and PET AIFs displayed similar character in the first pass, confirmed by gamma variate fits (p<0.02). MR AIFs displayed reduced PVE compared to PET AIFs, indicating their potential use in PET/MR studies.

  10. Comparison of first pass bolus AIFs extracted from sequential 18F-FDG PET and DSC-MRI of mice.

    PubMed

    Evans, Eleanor; Sawiak, Stephen J; Ward, Alexander O; Buonincontri, Guido; Hawkes, Robert C; Carpenter, T Adrian

    2014-01-11

    Accurate kinetic modelling of in vivo physiological function using positron emission tomography (PET) requires determination of the tracer time-activity curve in plasma, known as the arterial input function (AIF). The AIF is usually determined by invasive blood sampling methods, which are prohibitive in murine studies due to low total blood volumes. Extracting AIFs from PET images is also challenging due to large partial volume effects (PVE). We hypothesise that in combined PET with magnetic resonance imaging (PET/MR), a co-injected bolus of MR contrast agent and PET ligand can be tracked using fast MR acquisitions. This protocol would allow extraction of a MR AIF from MR contrast agent concentration-time curves, at higher spatial and temporal resolution than an image-derived PET AIF. A conversion factor could then be applied to the MR AIF for use in PET kinetic analysis. This work has compared AIFs obtained from sequential DSC-MRI and PET with separate injections of gadolinium contrast agent and 18 F-FDG respectively to ascertain the technique's validity. An automated voxel selection algorithm was employed to improve MR AIF reproducibility. We found that MR and PET AIFs displayed similar character in the first pass, confirmed by gamma variate fits (p<0.02). MR AIFs displayed reduced PVE compared to PET AIFs, indicating their potential use in PET/MR studies.

  11. An experimental phantom study of the effect of gadolinium-based MR contrast agents on PET attenuation coefficients and PET quantification in PET-MR imaging: application to cardiac studies.

    PubMed

    O' Doherty, Jim; Schleyer, Paul

    2017-12-01

    Simultaneous cardiac perfusion studies are an increasing trend in PET-MR imaging. During dynamic PET imaging, the introduction of gadolinium-based MR contrast agents (GBCA) at high concentrations during a dual injection of GBCA and PET radiotracer may cause increased attenuation effects of the PET signal, and thus errors in quantification of PET images. We thus aimed to calculate the change in linear attenuation coefficient (LAC) of a mixture of PET radiotracer and increasing concentrations of GBCA in solution and furthermore, to investigate if this change in LAC produced a measurable effect on the image-based PET activity concentration when attenuation corrected by three different AC strategies. We performed simultaneous PET-MR imaging of a phantom in a static scenario using a fixed activity of 40 MBq [18 F]-NaF, water, and an increasing GBCA concentration from 0 to 66 mM (based on an assumed maximum possible concentration of GBCA in the left ventricle in a clinical study). This simulated a range of clinical concentrations of GBCA. We investigated two methods to calculate the LAC of the solution mixture at 511 keV: (1) a mathematical mixture rule and (2) CT imaging of each concentration step and subsequent conversion to LAC at 511 keV. This comparison showed that the ranges of LAC produced by both methods are equivalent with an increase in LAC of the mixed solution of approximately 2% over the range of 0-66 mM. We then employed three different attenuation correction methods to the PET data: (1) each PET scan at a specific millimolar concentration of GBCA corrected by its corresponding CT scan, (2) each PET scan corrected by a CT scan with no GBCA present (i.e., at 0 mM GBCA), and (3) a manually generated attenuation map, whereby all CT voxels in the phantom at 0 mM were replaced by LAC = 0.1 cm -1 . All attenuation correction methods (1-3) were accurate to the true measured activity concentration within 5%, and there were no trends in image-based activity concentrations upon increasing the GBCA concentration of the solution. The presence of high GBCA concentration (representing a worst-case scenario in dynamic cardiac studies) in solution with PET radiotracer produces a minimal effect on attenuation-corrected PET quantification.

  12. Risk-related 18F-FDG PET/CT and new diagnostic strategies in patients with solitary pulmonary nodule: the ITALIAN multicenter trial.

    PubMed

    Spadafora, Marco; Pace, Leonardo; Evangelista, Laura; Mansi, Luigi; Del Prete, Francesco; Saladini, Giorgio; Miletto, Paolo; Fanti, Stefano; Del Vecchio, Silvana; Guerra, Luca; Pepe, Giovanna; Peluso, Giuseppina; Nicolai, Emanuele; Storto, Giovanni; Ferdeghini, Marco; Giordano, Alessandro; Farsad, Mohsen; Schillaci, Orazio; Gridelli, Cesare; Cuocolo, Alberto

    2018-05-05

    Diagnosis of solitary pulmonary nodule (SPN) is an important public health issue and 18 F-FDG PET/CT has proven to be more effective than CT alone. Pre-test risk stratification and clinical presentation of SPN could affect the diagnostic strategy. A relevant issue is whether thoracic segmental (s)-PET/CT could be implemented in patients with SPN. This retrospective multicenter study compared the results of FDG whole-body (wb)-PET/CT to those of s-PET/CT. 18 F-FDG PET/CT of 502 patients, stratified for pre-test cancer risk, were retrospectively analyzed. The thoracic part of wb-PET/CT, considered s-PET/CT, was compared to wb-PET/CT. Clinical and PET/CT variables were investigated for SPN characterization as well as for identification of patients in whom s-PET/CT could be performed. Histopathology or follow-up data were used as a reference. In the study population, 36% had malignant, 35% benign, and 29% indeterminate SPN. 18 F-FDG uptake indicative of thoracic and extra-thoracic lesions was detectable in 13% and 3% of the patients. All patients with extra-thoracic metastases (n = 13) had thoracic lymph node involvement and highest 18 F-FDG uptake at level of SPN (negative predictive value 100%). Compared to wb-PET/CT, s-PET/CT could save about 2/3 of 18 F-FDG dose, radiation exposure or scan-time, without affecting the clinical impact of PET/CT. Pre-test probability of malignancy can guide the diagnostic strategy of 18 FDG-PET/CT in patients with SPN. In subjects with low-intermediate pretest probability s-PET/CT imaging might be planned in advance, while in those at high risk and with thoracic lymph node involvement a wb-PET/CT is necessary.

  13. Towards quantitative PET/MRI: a review of MR-based attenuation correction techniques.

    PubMed

    Hofmann, Matthias; Pichler, Bernd; Schölkopf, Bernhard; Beyer, Thomas

    2009-03-01

    Positron emission tomography (PET) is a fully quantitative technology for imaging metabolic pathways and dynamic processes in vivo. Attenuation correction of raw PET data is a prerequisite for quantification and is typically based on separate transmission measurements. In PET/CT attenuation correction, however, is performed routinely based on the available CT transmission data. Recently, combined PET/magnetic resonance (MR) has been proposed as a viable alternative to PET/CT. Current concepts of PET/MRI do not include CT-like transmission sources and, therefore, alternative methods of PET attenuation correction must be found. This article reviews existing approaches to MR-based attenuation correction (MR-AC). Most groups have proposed MR-AC algorithms for brain PET studies and more recently also for torso PET/MR imaging. Most MR-AC strategies require the use of complementary MR and transmission images, or morphology templates generated from transmission images. We review and discuss these algorithms and point out challenges for using MR-AC in clinical routine. MR-AC is work-in-progress with potentially promising results from a template-based approach applicable to both brain and torso imaging. While efforts are ongoing in making clinically viable MR-AC fully automatic, further studies are required to realize the potential benefits of MR-based motion compensation and partial volume correction of the PET data.

  14. Canine Comfort: Pet Affinity Buffers the Negative Impact of Ambivalence over Emotional Expression on Perceived Social Support.

    PubMed

    Bryan, Jennifer L; Quist, Michelle C; Young, Chelsie M; Steers, Mai-Ly N; Foster, Dawn W; Lu, Qian

    2014-10-01

    This study evaluated pet affinity as a buffer between ambivalence over emotional expression (AEE) and social support. AEE occurs when one desires to express emotions but is reluctant to do so and is related to negative psychological outcomes. Individuals high in AEE may have difficulty receiving social support and thus may not gain accompanying benefits. Social support has been associated with positive health outcomes, and pet support is positively associated with human social support. The present study explores the potential protective effect of pet affinity. One hundred ninety-eight undergraduate dog owners completed measures assessing perceived social support, pet affinity, and AEE. AEE was expected to be negatively associated with social support, and pet affinity was expected to buffer the negative effects of AEE on social support. We found that AEE was negatively associated with perceived social support. An interaction between pet affinity and AEE emerged such that the negative association between AEE and social support was weaker among those higher in pet affinity. Thus, at high levels of AEE, those who felt a close connection with their pets reported more perceived social support than those less connected with their pets. Overall, these findings emphasize the potential benefits of pet affinity.

  15. 18F-Fluorodeoxyglucose Positron Emission Tomography/Magnetic Resonance in Lymphoma

    PubMed Central

    Giraudo, Chiara; Raderer, Markus; Karanikas, Georgios; Weber, Michael; Kiesewetter, Barbara; Dolak, Werner; Simonitsch-Klupp, Ingrid; Mayerhoefer, Marius E.

    2016-01-01

    Objectives The aim of this study was to compare 18F-fluorodeoxyglucose (FDG) positron emission tomography (PET)/magnetic resonance (MR) (with and without diffusion-weighted imaging [DWI]) to 18F-FDG PET/computed tomography (CT), with regard to the assessment of nodal and extranodal involvement, in patients with Hodgkin lymphoma and non-Hodgkin lymphoma, without restriction to FDG-avid subytpes. Materials and Methods Patients with histologically proven lymphoma were enrolled in this prospective, institutional review board–approved study. After a single 18F-FDG injection, patients consecutively underwent 18F-FDG PET⁄CT and 18F-FDG PET/MR on the same day for staging or restaging. Three sets of images were analyzed separately: 18F-FDG PET/CT, 18F-FDG PET/MR without DWI, and 18F-FDG PET/MR with DWI. Region-based agreement and examination-based sensitivity and specificity were calculated for 18F-FDG PET/CT, 18F-FDG PET/MR without DWI, and 18F-FDG PET/MR DWI. Maximum and mean standardized uptake values (SUVmax, SUVmean) on 18F-FDG PET/CT and 18F-FDG PET/MR were compared and correlated with minimum and mean apparent diffusion coefficients (ADCmin, ADCmean). Results Thirty-four patients with a total of 40 examinations were included. Examination-based sensitivities for 18F-FDG PET/CT, 18F-FDG PET/MR, and 18F-FDG PET/MR DWI were 82.1%, 85.7%, and 100%, respectively; specificities were 100% for all 3 techniques; and accuracies were 87.5%, 90%, and 100%, respectively. 18F-FDG PET/CT was false negative in 5 of 40 examinations (all with mucosa-associated lymphoid tissue lymphoma), and 18F-FDG PET/MR (without DWI) was false negative in 4 of 40 examinations. Region-based percentages of agreement were 99% (κ, 0.95) between 18F-FDG PET/MR DWI and 18F-FDG PET/CT, 99.2% (κ, 0.96) between 18F-FDG PET/MR and 18F-FDG PET/CT, and 99.4% (κ, 0.97) between 18F-FDG PET/MR DWI and 18F-FDG PET/MR. There was a strong correlation between 18F-FDG PET/CT and 18F-FDG PET/MR for SUVmax (r = 0.83) and SUVmean (r = 0.81) but no significant correlation between ADCmin and SUVmax (18F-FDG PET/CT: r = 0.46, P = 0.65; 18F-FDG PET/MR: r = 0.64, P = 0.53) or between ADCmean and SUVmean (respectively, r = −0.14, P = 0.17 for the correlation with PET/CT and r = −0.14, P = 0.14 for the correlation with PET/MR). Conclusions 18F-FDG PET/MR and 18F-FDG PET/CT show a similar diagnostic performance in lymphoma patients. However, if DWI is included in the 18F-FDG PET/MR protocol, results surpass those of 18F-FDG PET/CT because of the higher sensitivity of DWI for mucosa-associated lymphoid tissue lymphomas. PMID:26784400

  16. Sex Differences in the Neural Correlates of Autonomic Arousal: A Pilot PET Study

    PubMed Central

    Nugent, Allison C.; Bain, Earle E.; Thayer, Julian F.; Sollers, John J.; Drevets, Wayne C.

    2011-01-01

    Electrophysiology, behavioral, and neuroimaging studies have revealed sex-related differences in autonomic cardiac control, as reflected in measurements of heart rate variability (HRV). Imaging studies indicate that the neurobiological correlates of autonomic nervous system (ANS) function can be investigated by measuring indices of HRV during the performance of mildly strenuous motor tasks or mildly stressful cognitive tasks. In this preliminary study, fifteen male and seven female healthy subjects underwent H215O-positron emission tomography (PET) and electrocardiograph (ECG) recording while performing a handgrip motor task and an n-back task. Indices of HRV were calculated and correlated with regional cerebral blood flow (rCBF). We hypothesized that sex differences would be evident in brain regions known to participate in autonomic regulation: the anterior insula, the anterior cingulate cortex, the orbitofrontal cortex, and the amygdala. Our study found that associations between rCBF and parasympathetic indices differed significantly between female and male subjects in the amygdala. Females showed a positive correlation between rCBF and parasympathetic indices while males exhibited negative correlations. This differential correlation of amygdala rCBF and parasympathetic activity between males and females may reflect differences in parasympathetic/sympathetic balance between sexes, consistent with known sexual dimorphism in the amygdala and closely related structures such as the hypothalamus. These preliminary imaging results are consistent with earlier reports of significant correlation between brain activity and HRV, and extend these findings by demonstrating prominent sex differences in the neural control of the ANS. While the generalizability of our results was limited by the small size of the study samples, the relatively robust effect size of the differences found between groups encourages further work in larger samples to characterize sex differences in the neural correlates of autonomic arousal. PMID:21414364

  17. Combined early dynamic (18)F-FDG PET/CT and conventional whole-body (18)F-FDG PET/CT provide one-stop imaging for detecting hepatocellular carcinoma.

    PubMed

    Wang, Shao-Bo; Wu, Hu-Bing; Wang, Quan-Shi; Zhou, Wen-Lan; Tian, Ying; Li, Hong-Sheng; Ji, Yun-Hai; Lv, Liang

    2015-06-01

    It is widely accepted that conventional (18)F-FDG PET/CT (whole-body static (18)F-FDG PET/CT, WB (18)F-FDG PET/CT) has a low detection rate for hepatocellular carcinoma (HCC). We prospectively assessed the role of early dynamic (18)F-FDG PET/CT (ED (18)F-FDG PET/CT) and WB (18)F-FDG PET/CT in detecting HCC, and we quantified the added value of ED (18)F-FDG PET/CT to WB (18)F-FDG PET/CT. Twenty-two patients with 37 HCC tumors (HCCs) who underwent both a liver ED (18)F-FDG PET/CT (performed simultaneously with a 5.5 MBq/kg (18)F-FDG bolus injection and continued for 240 s) and a WB (18)F-FDG PET/CT were enrolled in the study. The WB (18)F-FDG PET/CT and ED (18)F-FDG PET/CT scans were positive in 56.7% (21/37) and 78.4% (29/37) HCCs, respectively (P<0.05). ED (18)F-FDG PET/CT in conjunction with WB (18)F-FDG PET/CT (one-stop (18)F-FDG PET/CT) improved the positive detection rates of WB and ED (18)F-FDG PET/CT alone from 56.7% and 78.4% to 91.9% (34/37) (P<0.001 and P>0.05, respectively). One-stop (18)F-FDG PET/CT appears to be useful to improve WB (18)F-FDG PET/CT for HCC detection. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  18. Clinical oncologic applications of PET/MRI: a new horizon

    PubMed Central

    Partovi, Sasan; Kohan, Andres; Rubbert, Christian; Vercher-Conejero, Jose Luis; Gaeta, Chiara; Yuh, Roger; Zipp, Lisa; Herrmann, Karin A; Robbin, Mark R; Lee, Zhenghong; Muzic, Raymond F; Faulhaber, Peter; Ros, Pablo R

    2014-01-01

    Positron emission tomography/magnetic resonance imaging (PET/MRI) leverages the high soft-tissue contrast and the functional sequences of MR with the molecular information of PET in one single, hybrid imaging technology. This technology, which was recently introduced into the clinical arena in a few medical centers worldwide, provides information about tumor biology and microenvironment. Studies on indirect PET/MRI (use of positron emission tomography/computed tomography (PET/CT) images software fused with MRI images) have already generated interesting preliminary data to pave the ground for potential applications of PET/MRI. These initial data convey that PET/MRI is promising in neuro-oncology and head & neck cancer applications as well as neoplasms in the abdomen and pelvis. The pediatric and young adult oncology population requiring frequent follow-up studies as well as pregnant woman might benefit from PET/MRI due to its lower ionizing radiation dose. The indication and planning of therapeutic interventions and specifically radiation therapy in individual patients could be and to a certain extent are already facilitated by performing PET/MRI. The objective of this article is to discuss potential clinical oncology indications of PET/MRI. PMID:24753986

  19. Simultaneous trimodal PET-MR-EEG imaging: Do EEG caps generate artefacts in PET images?

    PubMed

    Rajkumar, Ravichandran; Rota Kops, Elena; Mauler, Jörg; Tellmann, Lutz; Lerche, Christoph; Herzog, Hans; Shah, N Jon; Neuner, Irene

    2017-01-01

    Trimodal simultaneous acquisition of positron emission tomography (PET), magnetic resonance imaging (MRI), and electroencephalography (EEG) has become feasible due to the development of hybrid PET-MR scanners. To capture the temporal dynamics of neuronal activation on a millisecond-by-millisecond basis, an EEG system is appended to the quantitative high resolution PET-MR imaging modality already established in our institute. One of the major difficulties associated with the development of simultaneous trimodal acquisition is that the components traditionally used in each modality can cause interferences in its counterpart. The mutual interferences of MRI components and PET components on PET and MR images, and the influence of EEG electrodes on functional MRI images have been studied and reported on. Building on this, this study aims to investigate the influence of the EEG cap on the quality and quantification of PET images acquired during simultaneous PET-MR measurements. A preliminary transmission scan study on the ECAT HR+ scanner, using an Iida phantom, showed visible attenuation effect due to the EEG cap. The BrainPET-MR emission images of the Iida phantom with [18F]Fluordeoxyglucose, as well as of human subjects with the EEG cap, did not show significant effects of the EEG cap, even though the applied attenuation correction did not take into account the attenuation of the EEG cap itself.

  20. Household knowledge, attitudes and practices related to pet contact and associated zoonoses in Ontario, Canada

    PubMed Central

    2012-01-01

    Background Many human infections are transmitted through contact with animals (zoonoses), including household pets. Although pet ownership is common in most countries and non-pet owners may have frequent contact with pets, there is limited knowledge of the public’s pet contact practices and awareness of zoonotic disease risks from pets. The objective of this study was to characterize the general public’s knowledge, attitudes and risks related to pet ownership and animal contact in southern Ontario, Canada. Methods A self-administered questionnaire was distributed to individuals at two multi-physician clinics in Waterloo, Ontario, Canada during 2010. A single adult from each household was invited to participate in the study. Results Seventy five percent (641/853) of individuals approached completed the questionnaire. Pet ownership and contact were common; 64% of participants had a pet in their household and 37% of non-pet owning households had a member with at least weekly animal contact outside the home. Pet ownership was high (55%) for households with individuals at higher risk for infections (i.e., < 5 yrs, ≥ 65 yrs, immunocompromised). Most respondents (64%) indicated that they had never received information regarding pet-associated disease risks. When given a list of 11 infectious pathogens, respondents were only able to correctly classify just over half on their potential to be transmitted from pets to people (mean 6.4); independently, pet owners and those who recalled receiving information in the past about this topic were able to make significantly more correct identifications. Pet (36%) and non-pet owning households (10%) reported dog or cat bites or scratches during the preceding year. Households with individuals at higher risk for an infection did not differ from the remaining households regarding their perceived disease risk of pets, zoonotic disease knowledge, recall of being asked by their medical provider if they owned any pets, or recall of having received information regarding pet-associated disease risks and preventive measures. Conclusions These results suggest that there is a need for accessible zoonotic disease information for both pet and non-owning households, with additional efforts made by veterinary, human and public health personnel. Immediate educational efforts directed toward households with individuals at higher risk to infections are especially needed. PMID:22831165

  1. Use of PET/CT scanning in cancer patients: technical and practical considerations

    PubMed Central

    2005-01-01

    This overview of the oncologic applications of positron emission tomography (PET) focuses on the technical aspects and clinical applications of a newer technique: the combination of a PET scanner and a computed tomography (CT) scanner in a single (PET/CT) device. Examples illustrate how PET/CT contributes to patient care and improves upon the previous state-of-the-art method of comparing a PET scan with a separate CT scan. Finally, the author presents some of the results from studies of PET/CT imaging that are beginning to appear in the literature. PMID:16252023

  2. Does positron emission tomography/computed tomography aid the diagnosis of prosthetic valve infective endocarditis?

    PubMed

    Balmforth, Damian; Chacko, Jacob; Uppal, Rakesh

    2016-10-01

    A best evidence topic was constructed according to a structured protocol. The question addressed was whether (18)F-fluorodeoxyglucose positron emission tomography/computed tomography (PET/CT) aids the diagnosis of prosthetic valve endocarditis (PVE)? A total of 107 publications were found using the reported search, of which 6 represented the best evidence to answer the clinical question. The authors, journal, date and country of publication, patient group studied, study type, relevant outcomes and results of these papers are tabulated. The reported outcome of all studies was a final diagnosis of confirmed endocarditis on follow-up. All the six studies were non-randomized, single-centre, observational studies and thus represented level 3 evidence. The diagnostic capability of PET/CT for PVE was compared with that of the modified Duke Criteria and echocardiography, and reported in terms of sensitivity, specificity and positive and negative predictive values. All studies demonstrated an increased sensitivity for the diagnosis of PVE when PET/CT was combined with the modified Duke Criteria on admission. A higher SUVmax on PET was found to be significantly associated with a confirmed diagnosis of endocarditis and an additional diagnostic benefit of PET/CT angiography over conventional PET/non-enhanced CT is reported due to improved anatomical resolution. However, PET/CT was found to be unreliable in the early postoperative period due to its inability to distinguish between infection and residual postoperative inflammatory changes. PET/CT was also found to be poor at diagnosing cases of native valve endocarditis. We conclude that PET/CT aids in the diagnosis of PVE when combined with the modified Duke Criteria on admission by increasing the diagnostic sensitivity. The diagnostic ability of PET/CT can be potentiated by the use of PET/CTA; however, its use may be unreliable in the early postoperative period or in native valve endocarditis. © The Author 2016. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  3. A comparative study of FDG PET/CT and enhanced multi-detector CT for detecting liver metastasis according to the size and location.

    PubMed

    Park, Jung Mi; Kim, Il Young; Kim, Sang Won; Lee, Sang Mi; Kim, Hyun Gi; Kim, Shin Young; Shin, Hyung Chul

    2013-04-01

    The aim of this study was to compare the diagnosability between (18)F-fluorodeoxyglucose (FDG) PET/CT and enhanced multi-detector CT (MDCT) for the detection of liver metastasis (LM) according to the size and location in liver and to evaluate standard maximum standardized uptake values (SUVmax) of all liver metastatic lesions. One hundred two consecutive patients with malignancy who underwent both FDG PET/CT and MDCT for LM evaluation were retrospectively reviewed. Among them, 56 patients with LM were enrolled in this study. LM was confirmed by follow-up imaging studies after at least 6 months or by histopathology. FDG PET/CT and MDCT images were visually analyzed using three-point scale by the consensus of two radiologists and two nuclear medicine physicians. The size and location (central vs. sub-capsular) of the all liver lesions were evaluated using MDCT images. Furthermore, SUVmax of all liver lesions on FDG PET/CT images were calculated. A total of 146 liver lesions were detected by FDG PET/CT and MDCT and 142 of the lesions were diagnosed as LM. The detection rates of MDCT and FDG PET/CT for LM by visual analysis were 77 and 78%, respectively. There was no significant difference of detection rate according to the overall location and size of the lesions. However, FDG PET/CT was more sensitive than MDCT for detecting small and sub-capsular LM. The detection rate of FDG PET/CT for LM was 68% by the cutoff SUVmax of 2.7. Although the diagnosabilities of MDCT and FDG PET/CT for detecting LM were comparable, FDG PET/CT is superior to MDCT for detecting small LM located in the sub-capsular portion of liver.

  4. Dual tracer functional imaging of gastroenteropancreatic neuroendocrine tumors using 68Ga-DOTA-NOC PET-CT and 18F-FDG PET-CT: competitive or complimentary?

    PubMed

    Naswa, Niraj; Sharma, Punit; Gupta, Santosh Kumar; Karunanithi, Sellam; Reddy, Rama Mohan; Patnecha, Manish; Lata, Sneh; Kumar, Rakesh; Malhotra, Arun; Bal, Chandrasekhar

    2014-01-01

    This study aimed to compare the diagnostic performance of Ga-DOTANOC PET/CT with F-FDG PET/CT in the patients with gastroenteropancreatic neuroendocrine tumors (GEP-NETs). Data of 51 patients with definite histological diagnosis of GEP-NET who underwent both Ga-DOTA-NOC PET-CT and F-FDG PET-CT within a span of 15 days were selected for this retrospective analysis. Sensitivity, specificity, and predictive values were calculated for Ga-DOTA-NOC PET-CT and F-FDG PET-CT, and results were compared both on patientwise and regionwise analysis. Ga-DOTA-NOC PET-CT is superior to F-FDG PET-CT on patientwise analysis (P < 0.0001). On regionwise analysis, Ga-DOTA-NOC PET-CT is superior to F-FDG PET-CT only for lymph node metastases (P < 0.003). Although Ga-DOTA-NOC PET-CT detected more liver and skeletal lesions compared with F-FDG PET-CT, the difference was not statistically significant. In addition, the results of combined imaging helped in selecting candidates who would undergo the appropriate mode of treatment, whether octreotide therapy or conventional chemotherapy Ga-DOTA-NOC PET-CT seems to be superior to F-FDG PET-CT for imaging GEP-NETs. However, their role seems to be complementary because combination of Ga-DOTA-NOC PET-CT and F-FDG PET-CT in such patients helps demonstrate the total disease burden and segregate them to proper therapeutic groups.

  5. NEMA NU 4-2008 Performance Measurements of Two Commercial Small-Animal PET Scanners: ClearPET and rPET-1

    NASA Astrophysics Data System (ADS)

    Canadas, Mario; Embid, Miguel; Lage, Eduardo; Desco, Manuel; Vaquero, Juan José; Perez, José Manuel

    2011-02-01

    In this work, we compare two commercial positron emission tomography (PET) scanners installed at CIEMAT (Madrid, Spain): the ClearPET and the rPET-1. These systems have significant geometrical differences, such as the axial field of view (110 mm on ClearPET versus 45.6 mm on rPET-1), the configuration of the detectors (whole ring on ClearPET versus one pair of planar blocks on rPET-1) and the use of an axial shift between ClearPET detector modules. We used an assessment procedure that fulfilled the recommendations of the National Electrical Manufacturers Association (NEMA) NU 4-2008 standard. The methodology includes studies of spatial resolution, sensitivity, scatter fraction, count losses and image quality. Our experiments showed a central spatial resolution of 1.5 mm (transaxial), 3.2 mm (axial) for the ClearPET and 1.5 mm (transaxial), 1.6 mm (axial) for the rPET-1, with a small variation across the transverse axis on both scanners ( 1 mm). The absolute sensitivity at the centre of the field of view was 4.7% for the ClearPET and 1.0% for the rPET-1. The peak noise equivalent counting rate for the mouse-sized phantom was 73.4 kcps reached at 0.51 MBq/mL on the ClearPET and 29.2 kcps at 1.35 MBq/mL on the rPET-1. The recovery coefficients measured using the image quality phantom ranged from 0.11 to 0.89 on the ClearPET and from 0.14 to 0.81 on the rPET-1. The overall performance shows that both the ClearPET and the rPET-1 systems are very suitable for preclinical research and imaging of small animals.

  6. Childhood pet ownership, attachment to pets, and subsequent meat avoidance. The mediating role of empathy toward animals.

    PubMed

    Rothgerber, Hank; Mican, Frances

    2014-08-01

    Researchers studying childhood pet ownership outcomes do not typically focus on measures of adult diet, and those studying the psychology of meat consumption do not normally consider early experiences with companion animals. The present research sought to integrate these two areas by examining relationships between childhood pet ownership, pet attachment, empathy toward animals, belief in human-animal similarity, meat avoidance, and justifications for eating meat. Results from 273 individuals responding to a survey on an internet platform revealed that participants with greater childhood attachment to a pet reported greater meat avoidance as adults, an effect that disappeared when controlling for animal empathy. Greater childhood pet attachment was also related to the use of indirect, apologetic justifications for meat consumption, and this effect too, was mediated by empathy toward animals. Child pet ownership itself predicted views toward animals but not dietary behavior or meat-eating justifications. The authors propose a sequence of events by which greater childhood pet attachment leads to increased meat avoidance, focusing on the central role played by empathy toward animals. Copyright © 2014 Elsevier Ltd. All rights reserved.

  7. Another Breed of “Service” Animals: STARS Study Findings about Pet Ownership and Recovery from Serious Mental Illness

    PubMed Central

    Wisdom, Jennifer P.; Saedi, Goal Auzeen; Green, Carla A.

    2010-01-01

    This study elucidates the role of pets in recovery processes among adults with serious mental illness. Data derive from interviews with 177 HMO members with serious mental illness (52.2% women, average age 48.8). Interviews and questionnaires addressed factors affecting recovery processes and included questions about pet ownership. Data were analyzed using a modified grounded theory method to identify the roles pets play in the recovery process. Primary themes indicate pets assist individuals in recovery from serious mental illness by (a) providing empathy and “therapy”; (b) providing connections that can assist in redeveloping social avenues; (c) serving as “family” in the absence of or in addition to human family members; and (d) supporting self-efficacy and strengthening a sense of empowerment. Pets appear to provide more benefits than merely companionship. Participants’ reports of pet-related contributions to their well-being provide impetus to conduct more formal research on the mechanisms by which pets contribute to recovery and to develop pet-based interventions. PMID:19839680

  8. Quantitative assessment of atherosclerotic plaques on (18)F-FDG PET/MRI: comparison with a PET/CT hybrid system.

    PubMed

    Li, Xiang; Heber, Daniel; Rausch, Ivo; Beitzke, Dietrich; Mayerhoefer, Marius E; Rasul, Sazan; Kreissl, Michael; Mitthauser, Markus; Wadsak, Wolfgang; Hartenbach, Markus; Haug, Alexander; Zhang, Xiaoli; Loewe, Christian; Beyer, Thomas; Hacker, Marcus

    2016-07-01

    PET with (18)F-FDG has the potential to assess vascular macrophage metabolism. (18)F-FDG is most often used in combination with contrast-enhanced CT to localize increased metabolism to specific arterial lesions. Novel (18)F-FDG PET/MRI hybrid imaging shows high potential for the combined evaluation of atherosclerotic plaques, due to the superior morphological conspicuity of plaque lesions. The purpose of this study was to evaluate the reliability and accuracy of (18)F-FDG PET/MRI uptake quantification compared to PET/CT as a reference standard in patients with carotid atherosclerotic plaques. The study group comprised 34 consecutive oncological patients with carotid plaques who underwent both PET/CT and PET/MRI with (18)F-FDG on the same day. The presence of atherosclerotic plaques was confirmed by 3 T MRI scans. Maximum standardized uptake values (SUVmax) for carotid plaque lesions and the average SUV of the blood pool within the adjacent internal jugular vein were determined and target-to-blood ratios (TBRs, plaque to blood pool) were calculated. Atherosclerotic lesions with maximum colocalized focal FDG uptake were assessed in each patient. SUVmax values of carotid plaque lesions were significantly lower on PET/MRI than on PET/CT (2.3 ± 0.6 vs. 3.1 ± 0.6; P < 0.01), but were significantly correlated between PET/CT and PET/MRI (Spearman's r = 0.67, P < 0.01). In contrast, TBRmax values of plaque lesions were similar on PET/MRI and on PET/CT (2.2 ± 0.3 vs. 2.2 ± 0.3; P = 0.4), and again were significantly correlated between PET/MRI and PET/CT (Spearman's r = 0.73, P < 0.01). Considering the increasing trend in SUVmax and TBRmax values from early to delayed imaging time-points on PET/CT and PET/MRI, respectively, with continuous clearance of radioactivity from the blood, a slight underestimation of TBRmax values may also be expected with PET/MRI compared with PET/CT. SUVmax and TBRmax values are widely accepted reference parameters for estimation of the radioactivity of atherosclerotic plaques on PET/CT. However, due to a systematic underestimation of SUVmax and TBRmax with PET/MRI, the optimal cut-off values indicating the presence of inflamed plaque tissue need to be newly defined for PET/MRI.

  9. Diagnostic value of using 18F-FDG PET and PET/CT in immunocompetent patients with primary central nervous system lymphoma: A systematic review and meta-analysis.

    PubMed

    Zou, Yaru; Tong, Jianjing; Leng, Haiyan; Jiang, Jingwei; Pan, Meng; Chen, Zi

    2017-06-20

    18F-fluorodeoxyglucose (18F-FDG) positron emission tomography (PET) and PET/CT have become two of the most powerful tools for malignant lymphoma exploration, but their diagnostic role in primary central nervous system lymphoma (PCNSL) is still disputed. The purpose of our study is to identify the usefulness of 18F-FDG PET and PET/CT for detecting PCNSL. A total of 129 patients, obtained from eight eligible studies, were included for this systematic review and meta-analysis. The performance of 18F-FDG PET and PET/CT for diagnosing PCNSL were as follows: the pooled sensitivity was 0.88 (95% CI: 0.80-0.94), specificity was 0.86 (95% CI: 0.73-0.94), positive likelihood ratio (PLR) was 3.99 (95% CI: 2.31-6.90), negative likelihood ratio (NLR) was 0.11 (95% CI: 0.04-0.32), and diagnostic odds ratio (DOR) was 33.40 (95% CI: 10.40-107.3). In addition, the area under the curve (AUC) and Q index were 0.9192 and 0.8525, respectively. PubMed/MEDLINE, Embase and Cochrane Library were systematically searched for potential publications (last updated on July 16th, 2016). Reference lists of included articles were also checked. Original articles that reported data on patients who were suspected of having PCNSL were considered suitable for inclusion. The sensitivities and specificities of 18F-FDG PET and PET/CT in each study were evaluated. The Stata software and Meta-Disc software were employed in the process of data analysis. 18F-FDG PET and PET/CT showed considerable accuracy in identifying PCNSL in immunocompetent patients and could be a valuable radiological diagnostic tool for PCNSL.

  10. MR-assisted PET Motion Correction for eurological Studies in an Integrated MR-PET Scanner

    PubMed Central

    Catana, Ciprian; Benner, Thomas; van der Kouwe, Andre; Byars, Larry; Hamm, Michael; Chonde, Daniel B.; Michel, Christian J.; El Fakhri, Georges; Schmand, Matthias; Sorensen, A. Gregory

    2011-01-01

    Head motion is difficult to avoid in long PET studies, degrading the image quality and offsetting the benefit of using a high-resolution scanner. As a potential solution in an integrated MR-PET scanner, the simultaneously acquired MR data can be used for motion tracking. In this work, a novel data processing and rigid-body motion correction (MC) algorithm for the MR-compatible BrainPET prototype scanner is described and proof-of-principle phantom and human studies are presented. Methods To account for motion, the PET prompts and randoms coincidences as well as the sensitivity data are processed in the line or response (LOR) space according to the MR-derived motion estimates. After sinogram space rebinning, the corrected data are summed and the motion corrected PET volume is reconstructed from these sinograms and the attenuation and scatter sinograms in the reference position. The accuracy of the MC algorithm was first tested using a Hoffman phantom. Next, human volunteer studies were performed and motion estimates were obtained using two high temporal resolution MR-based motion tracking techniques. Results After accounting for the physical mismatch between the two scanners, perfectly co-registered MR and PET volumes are reproducibly obtained. The MR output gates inserted in to the PET list-mode allow the temporal correlation of the two data sets within 0.2 s. The Hoffman phantom volume reconstructed processing the PET data in the LOR space was similar to the one obtained processing the data using the standard methods and applying the MC in the image space, demonstrating the quantitative accuracy of the novel MC algorithm. In human volunteer studies, motion estimates were obtained from echo planar imaging and cloverleaf navigator sequences every 3 seconds and 20 ms, respectively. Substantially improved PET images with excellent delineation of specific brain structures were obtained after applying the MC using these MR-based estimates. Conclusion A novel MR-based MC algorithm was developed for the integrated MR-PET scanner. High temporal resolution MR-derived motion estimates (obtained while simultaneously acquiring anatomical or functional MR data) can be used for PET MC. An MR-based MC has the potential to improve PET as a quantitative method, increasing its reliability and reproducibility which could benefit a large number of neurological applications. PMID:21189415

  11. PET/MRI in cancer patients: first experiences and vision from Copenhagen.

    PubMed

    Kjær, Andreas; Loft, Annika; Law, Ian; Berthelsen, Anne Kiil; Borgwardt, Lise; Löfgren, Johan; Johnbeck, Camilla Bardram; Hansen, Adam Espe; Keller, Sune; Holm, Søren; Højgaard, Liselotte

    2013-02-01

    Combined PET/MRI systems are now commercially available and are expected to change the medical imaging field by providing combined anato-metabolic image information. We believe this will be of particular relevance in imaging of cancer patients. At the Department of Clinical Physiology, Nuclear Medicine & PET at Rigshospitalet in Copenhagen we installed an integrated PET/MRI in December 2011. Here, we describe our first clinical PET/MR cases and discuss some of the areas within oncology where we envision promising future application of integrated PET/MR imaging in clinical routine. Cases described include brain tumors, pediatric oncology as well as lung, abdominal and pelvic cancer. In general the cases show that PET/MRI performs well in all these types of cancer when compared to PET/CT. However, future large-scale clinical studies are needed to establish when to use PET/MRI. We envision that PET/MRI in oncology will prove to become a valuable addition to PET/CT in diagnosing, tailoring and monitoring cancer therapy in selected patient populations.

  12. Optimization of the protocols for the use of contrast agents in PET/CT studies.

    PubMed

    Pelegrí Martínez, L; Kohan, A A; Vercher Conejero, J L

    The introduction of PET/CT scanners in clinical practice in 1998 has improved care for oncologic patients throughout the clinical pathway, from the initial diagnosis of disease through the evaluation of the response to treatment to screening for possible recurrence. The CT component of a PET/CT study is used to correct the attenuation of PET studies; CT also provides anatomic information about the distribution of the radiotracer. CT is especially useful in situations where PET alone can lead to false positives and false negatives, and CT thereby improves the diagnostic performance of PET. The use of intravenous or oral contrast agents and optimal CT protocols have improved the detection and characterization of lesions. However, there are circumstances in which the systematic use of contrast agents is not justified. The standard acquisition in PET/CT scanners is the whole body protocol, but this can lead to artifacts due to the position of patients and respiratory movements between the CT and PET acquisitions. This article discusses these aspects from a constructive perspective with the aim of maximizing the diagnostic potential of PET/CT and providing better care for patients. Copyright © 2016 SERAM. Publicado por Elsevier España, S.L.U. All rights reserved.

  13. Injuries caused by pets in Asian urban households: a cross-sectional telephone survey.

    PubMed

    Chan, Emily Y Y; Gao, Yang; Li, Liping; Lee, Po Yi

    2017-01-20

    Little is known about pet-related injuries in Asian populations. This study primarily aimed to investigate the incidence rate of pet-related household injuries in Hong Kong, an urban Chinese setting. Cantonese-speaking non-institutionalised population of all ages in Hong Kong accessible by telephone land-line. A total of 43 542 telephone numbers were dialled and 6570 residents successfully completed the interviews. Data of pet-related household injuries in the previous 12 months, pet ownership and socio-demographic characteristics were collected with a questionnaire. Direct standardisation of the incidence rates of pet-related household injuries by gender and age to the 2009 Hong Kong Population Census was estimated. Univariate and multivariate analyses were performed to estimate risks of socio-demographic factors and pet ownership for the injury. A total of 84 participants experienced pet-related household injuries in the past 12 months, with an overall person-based incidence rate of 1.28%. The majority of the victims were injured once (69.6%). Cats (51.6%) were the most common pets involved. Pet owners were at an extremely higher risk after controlling for other factors (adjusted OR: 52.0, 95% CI 22.1 to 98.7). Females, the unmarried, those with higher monthly household income and those living in lower-density housing were more likely to be injured by pets. We project a pet-related household injury incidence rate of 1.24% in the general Hong Kong population, with 86 334 residents sustaining pet-related injuries every year. Pet ownership puts people at extremely high risk, especially the unmarried. Further studies should focus on educating pet owners to reduce pet-related injuries in urban Greater China. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  14. Prognostic significance of SUV on PET/CT in patients with localised oesophagogastric junction cancer receiving neoadjuvant chemotherapy/chemoradiation:a systematic review and meta-analysis.

    PubMed

    Zhu, W; Xing, L; Yue, J; Sun, X; Sun, X; Zhao, H; Yu, J

    2012-09-01

    The objective of this study was to comprehensively review the evidence for use of pre-treatment, post-treatment and changes in tumour glucose uptake that were assessed by 18-fludeoxyglucose ((18)F-FDG) positron emission tomography (PET) early, during or immediately after neoadjuvant chemotherapy/chemoradiation to predict prognosis of localised oesophagogastric junction (AEG) cancer. We searched for articles published in English; limited to AEG; (18)F-FDG uptake on PET performed on a dedicated device; dealt with the impact of standard uptake value (SUV) on survival. We extracted an estimate of the log hazard ratios (HRs) and their variances and performed meta-analysis. 798 patients with AEG were included. And the scan time for (18)F-FDG-PET was as follows: prior to therapy (PET1, n=646), exactly 2 weeks after initiation of neoadjuvant therapy (PET2, n=245), and pre-operatively (PET3, n=278). In the two meta-analyses for overall survival, including the studies that dealt with reduction of tumour maximum SUV (SUV(max)) (from PET1 to PET2/PET3 and from PET1 to PET2), the results were similar, with the overall HR for non-responders being 1.83 [95% confidence interval (CI), 1.41-2.36] and 2.62 (95% CI, 1.61-4.26), respectively; as for disease-free survival, the combined HR was 2.92 (95% CI, 2.08-4.10) and 2.39 (95% CI, 1.57-3.64), respectively. The meta-analyses did not attribute significant prognostic values to SUV(max) before and during therapy in localised AEG. Relative changes in FDG-uptake of AEG are better prognosticators. Early metabolic changes from PET1 to PET2 may provide the same accuracy for prediction of treatment outcome as late changes from PET1 to PET3.

  15. Diagnosis of metastases from postoperative differentiated thyroid cancer: comparison between FDG and FLT PET/CT studies.

    PubMed

    Nakajo, Masatoyo; Nakajo, Masayuki; Jinguji, Megumi; Tani, Atsushi; Kajiya, Yoriko; Tanabe, Hiroaki; Fukukura, Yoshihiko; Nakabeppu, Yoshiaki; Koriyama, Chihaya

    2013-06-01

    To compare positron emission tomography (PET)/computed tomography (CT) studies performed with the glucose analog fluorine 18 ((18)F) fluorodeoxyglucose (FDG) and the cell proliferation tracer (18)F fluorothymidine (FLT) in the diagnosis of metastases from postoperative differentiated thyroid cancer. The institutional ethics review board approved this prospective study. From March 2010 to February 2012, 20 patients (mean age, 53 years; age range, 22-79 years) with postoperative differentiated thyroid cancer underwent both FDG and FLT PET/CT as a staging work-up before radioiodine therapy. In each patient, 28 anatomic areas were set and analyzed for lymph node and distant metastases. The McNemar exact or χ(2) test was used to examine differences in diagnostic indexes in the detection of lymph node and distant metastases between both tracer PET/CT studies. There were 34 lymph node metastases and/or 73 distant metastases (70 metastases in lung and one each in bone, nasopharynx, and brain) in 13 patients. At patient-based analysis, the sensitivity, specificity, and accuracy were 92% (12 of 13 patients), 86% (six of seven patients), and 90% (18 of 20 patients), respectively, for FDG PET/CT and 69% (nine of 13 patients), 29% (two of seven patients), and 55% (11 of 20 patients) for FLT PET/CT. The accuracy of FDG PET/CT was significantly better than that of FLT PET/CT (P = .023). At lesion-based analysis, the sensitivity, specificity, and accuracy for diagnosing lymph node metastases were 85% (29 of 34 lesions), 99.6% (245 of 246 lesions), and 97.9% (274 of 280 lesions), respectively, for FDG PET/CT and 50% (17 of 34 lesions), 90.7% (223 of 246 lesions), and 85.7% (240 of 280 lesions) for FLT PET/CT. The sensitivity, specificity, and accuracy for diagnosing distant metastases were 45% (33 of 73 lesions), 100% (207 of 207 lesions), and 85.7% (240 of 280 lesions), respectively, for FDG PET/CT and 6.8% (five of 73 lesions), 100% (207 of 207 lesions), and 75.7% (212 of 280 lesions) for FLT PET/CT. The sensitivity (P = .002), specificity (P < .001), and accuracy (P < .001) of FDG PET/CT in the diagnosis of lymph node metastases were superior to those of FLT PET, as were the sensitivity (P < .001) and accuracy (P < .001) in the diagnosis of distant metastases. FDG PET/CT is superior to FLT PET/CT in the diagnosis of postoperative differentiated thyroid cancer lymph node and distant metastases. Thus, FDG PET/CT is more suitable than FLT PET/CT for examining recurrence of postoperative differentiated thyroid cancer.

  16. 18F-FDG PET of the hands with a dedicated high-resolution PEM system (arthro-PET): correlation with PET/CT, radiography and clinical parameters.

    PubMed

    Mhlanga, Joyce C; Carrino, John A; Lodge, Martin; Wang, Hao; Wahl, Richard L

    2014-12-01

    The aim of this study was to prospectively determine the feasibility and compare the novel use of a positron emission mammography (PEM) scanner with standard PET/CT for evaluating hand osteoarthritis (OA) with (18)F-FDG. Institutional review board approval and written informed consent were obtained for this HIPAA-compliant prospective study in which 14 adults referred for oncological (18)F-FDG PET/CT underwent dedicated hand PET/CT followed by arthro-PET using the PEM device. Hand radiographs were obtained and scored for the presence and severity of OA. Summed qualitative and quantitative joint glycolytic scores for each modality were compared with the findings on plain radiography and clinical features. Eight patients with clinical and/or radiographic evidence of OA comprised the OA group (mean age 73 ± 7.7 years). Six patients served as the control group (53.7 ± 9.3 years). Arthro-PET quantitative and qualitative joint glycolytic scores were highly correlated with PET/CT findings in the OA patients (r = 0.86. p = 0.007; r = 0.94, p = 0.001). Qualitative arthro-PET and PET/CT joint scores were significantly higher in the OA patients than in controls (38.7 ± 6.6 vs. 32.2 ± 0.4, p = 0.02; 37.5 ± 5.4 vs. 32.2 ± 0.4, p = 0.03, respectively). Quantitative arthro-PET and PET/CT maximum SUV-lean joint scores were higher in the OA patients, although they did not reach statistical significance (20.8 ± 4.2 vs. 18 ± 1.8, p = 0.13; 22.8 ± 5.38 vs. 20.1 ± 1.54, p = 0.21). By definition, OA patients had higher radiographic joint scores than controls (30.9 ± 31.3 vs. 0, p = 0.03). Hand imaging using a small field of view PEM system (arthro-PET) with FDG is feasible, performing comparably to PET/CT in assessing metabolic joint activity. Arthro-PET and PET/CT showed higher joint FDG uptake in OA. Further exploration of arthro-PET in arthritis management is warranted.

  17. 18F-FDG PET of the hands with a dedicated high-resolution PEM system (arthro-PET): correlation with PET/CT, radiography and clinical parameters

    PubMed Central

    Mhlanga, Joyce C.; Carrino, John A.; Lodge, Martin; Wang, Hao

    2015-01-01

    Purpose The aim of this study was to prospectively determine the feasibility and compare the novel use of a positron emission mammography (PEM) scanner with standard PET/CT for evaluating hand osteoarthritis (OA) with 18F-FDG. Methods Institutional review board approval and written informed consent were obtained for this HIPAA-compliant prospective study in which 14 adults referred for oncological 18F-FDG PET/CT underwent dedicated hand PET/CT followed by arthro-PET using the PEM device. Hand radiographs were obtained and scored for the presence and severity of OA. Summed qualitative and quantitative joint glycolytic scores for each modality were compared with the findings on plain radiography and clinical features. Results Eight patients with clinical and/or radiographic evidence of OA comprised the OA group (mean age 73±7.7 years). Six patients served as the control group (53.7±9.3 years). Arthro-PET quantitative and qualitative joint glycolytic scores were highly correlated with PET/CT findings in the OA patients (r=0.86. p =0.007; r=0.94, p=0.001). Qualitative arthro-PET and PET/CT joint scores were significantly higher in the OA patients than in controls (38.7±6.6 vs. 32.2±0.4, p=0.02; 37.5±5.4 vs. 32.2±0.4, p=0.03, respectively). Quantitative arthro-PET and PET/CT maximum SUV-lean joint scores were higher in the OA patients, although they did not reach statistical significance (20.8±4.2 vs. 18±1.8, p= 0.13; 22.8±5.38 vs. 20.1±1.54, p=0.21). By definition, OA patients had higher radiographic joint scores than controls (30.9±31.3 vs. 0, p=0.03). Conclusion Hand imaging using a small field of view PEM system (arthro-PET) with FDG is feasible, performing comparably to PET/CT in assessing metabolic joint activity. Arthro-PET and PET/CT showed higher joint FDG uptake in OA. Further exploration of arthro-PET in arthritis management is warranted. PMID:25134669

  18. PET AND SPECT STUDIES IN CHILDREN WITH HEMISPHERIC LOW-GRADE GLIOMAS

    PubMed Central

    Juhász, Csaba; Bosnyák, Edit

    2016-01-01

    Molecular imaging is playing an increasing role in the pre-treatment evaluation of low-grade gliomas. While glucose positron emission tomography (PET) can be helpful to differentiate low-grade from high-grade tumors, PET imaging with amino acid radiotracers has several advantages, such as better differentiation between tumors and non-tumorous lesions, optimized biopsy targeting and improved detection of tumor recurrence. This review provides a brief overview of single photon emission computed tomography (SPECT) studies followed by a more detailed review of clinical applications of glucose and amino acid PET imaging in low-grade hemispheric gliomas. We discuss key differences in the performance of the most commonly utilized PET radiotracers and highlight the advantage of PET/MRI fusion to obtain optimal information about tumor extent, heterogeneity and metabolism. Recent data also suggest that simultaneous acquisition of PET/MR images and the combination of advanced MRI techniques with quantitative PET can further improve the pre- and post-treatment evaluation of pediatric brain tumors. PMID:27659825

  19. PET and SPECT studies in children with hemispheric low-grade gliomas.

    PubMed

    Juhász, Csaba; Bosnyák, Edit

    2016-10-01

    Molecular imaging is playing an increasing role in the pretreatment evaluation of low-grade gliomas. While glucose positron emission tomography (PET) can be helpful to differentiate low-grade from high-grade tumors, PET imaging with amino acid radiotracers has several advantages, such as better differentiation between tumors and non-tumorous lesions, optimized biopsy targeting, and improved detection of tumor recurrence. This review provides a brief overview of single-photon emission computed tomography (SPECT) studies followed by a more detailed review of the clinical applications of glucose and amino acid PET imaging in low-grade hemispheric gliomas. We discuss key differences in the performance of the most commonly utilized PET radiotracers and highlight the advantage of PET/MRI fusion to obtain optimal information about tumor extent, heterogeneity, and metabolism. Recent data also suggest that simultaneous acquisition of PET/MR images and the combination of advanced MRI techniques with quantitative PET can further improve the pretreatment and post-treatment evaluation of pediatric brain tumors.

  20. Investigation of cis-4-[18F]Fluoro-D-Proline Uptake in Human Brain Tumors After Multimodal Treatment.

    PubMed

    Verger, Antoine; Stoffels, Gabriele; Galldiks, Norbert; Lohmann, Philipp; Willuweit, Antje; Neumaier, Bernd; Geisler, Stefanie; Langen, Karl-Josef

    2018-04-23

    Cis-4-[ 18 F]fluoro-D-proline (D-cis-[ 18 F]FPro) has been shown to pass the intact blood-brain barrier and to accumulate in areas of secondary neurodegeneration and necrosis in the rat brain while uptake in experimental brain tumors is low. This pilot study explores the uptake behavior of D-cis-[ 18 F]FPro in human brain tumors after multimodal treatment. In a prospective study, 27 patients with suspected recurrent brain tumor after treatment with surgery, radiotherapy, and/or chemotherapy (SRC) were investigated by dynamic positron emission tomography (PET) using D-cis-[ 18 F]FPro (22 high-grade gliomas, one unspecified glioma, and 4 metastases). Furthermore, two patients with untreated lesions were included (one glioblastoma, one reactive astrogliosis). Data were compared with the results of PET using O-(2-[ 18 F]fluoroethyl)-L-tyrosine ([ 18 F]FET) which detects viable tumor tissue. Tracer distribution, mean and maximum lesion-to-brain ratios (LBR mean , LBR max ), and time-to-peak (TTP) of the time activity curve (TAC) of tracer uptake were evaluated. Final diagnosis was determined by histology (n = 9), clinical follow-up (n = 10), or by [ 18 F]FET PET (n = 10). D-cis-[ 18 F]FPro showed high uptake in both recurrent brain tumors (n = 11) and lesions classified as treatment-related changes (TRC) only (n = 16) (LBR mean 2.2 ± 0.7 and 2.1 ± 0.6, n.s.; LBR max 3.4 ± 1.2 and 3.2 ± 1.3, n.s.). The untreated glioblastoma and the lesion showing reactive astrogliosis exhibited low D-cis-[ 18 F]FPro uptake. Distribution of [ 18 F]FET and D-cis-[ 18 F]FPro uptake was discordant in 21/29 cases indicating that the uptake mechanisms are different. The high accumulation of D-cis-[ 18 F]FPro in pretreated brain tumors and TRC supports the hypothesis that tracer uptake is related to cell death. Further studies before and after therapy are needed to assess the potential of D-cis-[ 18 F]FPro for treatment monitoring.

  1. Analysis of 18F-fluorodeoxy-glucose PET imaging data captured before and after Pc 4-mediated photodynamic therapy of U87 tumors in the athymic nude rat

    NASA Astrophysics Data System (ADS)

    Cross, Nathan; Varghai, Davood; Spring-Robinson, Chandra; Sharma, Rahul; Muzic, Raymond F., Jr.; Oleinick, Nancy L.; Dean, D.

    2007-02-01

    Introduction: Several workers have proposed the use of PET (Positron Emission Tomography) imaging for the outcome assessment of photodynamic therapy (PDT), especially for deep-seated tumors. We report on our study of 18Ffluorodeoxy- glucose (18F-FDG) PET imaging following brain tumor Pc4-PDT. Our working hypothesis was that the tumor's metabolic activity would decline dramatically following Pc 4-PDT owing to tumor necrosis. Methods: Seven days after intraparenchymal implantation of U87 cells, the brains of 12 athymic nude rats were imaged by micro-CT and/or micro-MR. These animals were also 18F-FDG micro-PET (μPET) scanned before and after Pc 4-PDT. 18F-FDG was used to trace metabolic activity that was monitored via μPET. Occurrence of PDT was confirmed on histology. The analysis of 18F-FDG dose and animal weight normalized μPET activity was studied over the 90 minute µPET scan. Results: Currently, μPET data have been studied for: (1) three of the animals that did not indicate tumor necrosis on histology and were assigned to a "Non-PDT" group, and (2) six animals that exhibited tumor necrosis on histology and were assigned to a "PDT" group. The μPET-detected 18F-FDG uptake activity in the tumor region before and after photoirradiation increased in the Non-PDT group an average of 2.28 times, and in the PDT group it increased an average of 1.15 times. Discussion: We are investigating the cause of the increase in 18F-FDG μPET activity that we observed in the PDT group. The methodology used in this study should be useful in determining whether this or other PET, SPECT, or MR functional imaging protocols will detect both the specificity and sensitivity of brain tumor necrosis following Pc 4-PDT.

  2. Evaluation of scatter limitation correction: a new method of correcting photopenic artifacts caused by patient motion during whole-body PET/CT imaging.

    PubMed

    Miwa, Kenta; Umeda, Takuro; Murata, Taisuke; Wagatsuma, Kei; Miyaji, Noriaki; Terauchi, Takashi; Koizumi, Mitsuru; Sasaki, Masayuki

    2016-02-01

    Overcorrection of scatter caused by patient motion during whole-body PET/computed tomography (CT) imaging can induce the appearance of photopenic artifacts in the PET images. The present study aimed to quantify the accuracy of scatter limitation correction (SLC) for eliminating photopenic artifacts. This study analyzed photopenic artifacts in (18)F-fluorodeoxyglucose ((18)F-FDG) PET/CT images acquired from 12 patients and from a National Electrical Manufacturers Association phantom with two peripheral plastic bottles that simulated the human body and arms, respectively. The phantom comprised a sphere (diameter, 10 or 37 mm) containing fluorine-18 solutions with target-to-background ratios of 2, 4, and 8. The plastic bottles were moved 10 cm posteriorly between CT and PET acquisitions. All PET data were reconstructed using model-based scatter correction (SC), no scatter correction (NSC), and SLC, and the presence or absence of artifacts on the PET images was visually evaluated. The SC and SLC images were also semiquantitatively evaluated using standardized uptake values (SUVs). Photopenic artifacts were not recognizable in any NSC and SLC image from all 12 patients in the clinical study. The SUVmax of mismatched SLC PET/CT images were almost equal to those of matched SC and SLC PET/CT images. Applying NSC and SLC substantially eliminated the photopenic artifacts on SC PET images in the phantom study. SLC improved the activity concentration of the sphere for all target-to-background ratios. The highest %errors of the 10 and 37-mm spheres were 93.3 and 58.3%, respectively, for mismatched SC, and 73.2 and 22.0%, respectively, for mismatched SLC. Photopenic artifacts caused by SC error induced by CT and PET image misalignment were corrected using SLC, indicating that this method is useful and practical for clinical qualitative and quantitative PET/CT assessment.

  3. 68Ga-PSMA-11 Dynamic PET/CT Imaging in Primary Prostate Cancer.

    PubMed

    Sachpekidis, Christos; Kopka, Klaus; Eder, Matthias; Hadaschik, Boris A; Freitag, Martin T; Pan, Leyun; Haberkorn, Uwe; Dimitrakopoulou-Strauss, Antonia

    2016-11-01

    The aim of our study is to assess the pharmacokinetics and biodistribution of Ga-PSMA-11 in patients suffering from primary prostate cancer (PC) by means of dynamic and whole-body PET/CT. Twenty-four patients with primary, previously untreated PC were enrolled in the study. All patients underwent dynamic PET/CT (dPET/CT) scanning of the pelvis and whole-body PET/CT studies with Ga-PSMA-11. The evaluation of dPET/CT studies was based on qualitative evaluation, SUV calculation, and quantitative analysis based on two-tissue compartment modeling and a noncompartmental approach leading to the extraction of fractal dimension (FD). A total of 23/24 patients (95.8%) were Ga-PSMA-11 positive. In 9/24 patients (37.5%), metastatic lesions were detected. PC-associated lesions demonstrated the following mean values: SUVaverage = 14.3, SUVmax = 23.4, K1 = 0.24 (1/min), k3 = 0.34 (1/min), influx = 0.15 (1/min), and FD = 1.27. The parameters SUVaverage, SUVmax, k3, influx, and FD derived from PC-associated lesions were significantly higher than respective values derived from reference prostate tissue. Time-activity curves derived from PC-associated lesions revealed an increasing Ga-PSMA-11 accumulation during dynamic PET acquisition. Correlation analysis revealed a moderate but significant correlation between PSA levels and SUVaverage (r = 0.60) and SUVmax (r = 0.57), and a weak but significant correlation between Gleason score and SUVaverage (r = 0.33) and SUVmax (r = 0.28). Ga-PSMA-11 PET/CT confirmed its capacity in detecting primary PC with a detection rate of 95.8%. Dynamic PET/CT studies of the pelvis revealed an increase in tracer uptake in PC-associated lesions during the 60 minutes of dynamic PET acquisition, a finding with potential applications in anti-PSMA approaches.

  4. Diagnostic performance of Fluorine-18-Fluorodeoxyglucose positron emission tomography for the diagnosis of osteomyelitis related to diabetic foot: a systematic review and a meta-analysis.

    PubMed

    Treglia, Giorgio; Sadeghi, Ramin; Annunziata, Salvatore; Zakavi, Seyed Rasoul; Caldarella, Carmelo; Muoio, Barbara; Bertagna, Francesco; Ceriani, Luca; Giovanella, Luca

    2013-12-01

    To systematically review and meta-analyse published data about the diagnostic performance of Fluorine-18-Fluorodeoxyglucose ((18)F-FDG) positron emission tomography (PET) and PET/computed tomography (PET/CT) in osteomyelitis related to diabetic foot. A comprehensive literature search of studies on (18)F-FDG-PET and PET/CT in patients with diabetic foot was performed. Pooled sensitivity, specificity, positive and negative likelihood ratio (LR+ and LR-) and diagnostic odds ratio (DOR) and area under the summary ROC curve of (18)F-FDG-PET and PET/CT in patients with osteomyelitis related to diabetic foot were calculated. Nine studies comprising 299 patients with diabetic foot were included in the qualitative analysis (systematic review) and discussed. The quantitative analysis (meta-analysis) of four selected studies provided the following results on a per patient-based analysis: sensitivity was 74% [95% confidence interval (95%CI): 60-85%], specificity 91% (95%CI: 85-96%), LR+ 5.56 (95%CI: 2.02-15.27), LR- 0.37 (95%CI: 0.10-1.35), and DOR 16.96 (95%CI: 2.06-139.66). The area under the summary ROC curve was 0.874. In patients with suspected osteomyelitis related to diabetic foot (18)F-FDG-PET and PET/CT demonstrated a high specificity, being potentially useful tools if combined with other imaging methods such as MRI. Nevertheless, the literature focusing on the use of (18)F-FDG-PET and PET/CT in this setting remains still limited. Copyright © 2013 Elsevier Ltd. All rights reserved.

  5. Improvement of PET surface hydrophilicity and roughness through blending

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kolahchi, Ahmad Rezaei; Ajji, Abdellah; Carreau, Pierre J.

    Controlling the adhesion of the polymer surface is a key issue in surface science, since polymers have been a commonly used material for many years. The surface modification in this study includes two different aspects. One is to enhance the hydrophilicity and the other is to create the roughness on the PET film surface. In this study we developed a novel and simple approach to modify polyethylene terephthalate (PET) film surface through polymer blending in twin-screw extruder. One example described in the study uses polyethylene glycol (PEG) in polyethylene terephthalate (PET) host to modify a PET film surface. Low contentmore » of polystyrene (PS) as a third component was used in the system to increase the rate of migration of PEG to the surface of the film. Surface enrichment of PEG was observed at the polymer/air interface of the polymer film containing PET-PEG-PS whereas for the PET-PEG binary blend more PEG was distributed within the bulk of the sample. Furthermore, a novel method to create roughness at the PET film surface was proposed. In order to roughen the surface of PET film, a small amount of PKHH phenoxy resin to change PS/PET interfacial tension was used. The compatibility effect of PKHH causes the formation of smaller PS droplets, which were able to migrate more easily through PET matrix. Consequently, resulting in a locally elevated concentration of PS near the surface of the film. The local concentration of PS eventually reached a level where a co-continuous morphology occurred, resulting in theinstabilities on the surface of the film.« less

  6. Driving with Pets as a Risk Factor for Motor Vehicle Collisions among Older Drivers

    PubMed Central

    Blunck, Hallie; Owsley, Cynthia; MacLennan, Paul A.; McGwin, Gerald

    2015-01-01

    Increasing rates of distraction-related motor vehicle collisions (MVCs) continue to raise concerns regarding driving safety. This study sought to evaluate a novel driving-related distraction, driving with a pet, as a risk factor for MVCs among older, community dwelling adults. Two thousand licensed drivers aged 70 and older were identified, of whom 691 reported pet ownership. Comparing pet owners who did and did not drive with their pets, neither overall MVC rates (rate ratio [RR] 0.97 95% confidence interval [CI] 0.75–1.26) nor at-fault MVC rates (RR 0.84 95% CI 0.57–1.24) were elevated. However, those who reported always driving with a pet in the vehicle had an elevated MVC rate (RR 1.89 95% CI 1.10–3.25), as compared to those who did not drive with a pet. The MVC rate was not increased for those reporting only sometimes or rarely driving with a pet in the vehicle. The current study demonstrates an increased risk of MVC involvement in those older drivers who always take a pet with them when they drive a vehicle. When confronted with an increased cognitive or physical workload while driving, elderly drivers in prior studies have exhibited slower cognitive performance and delayed response times in comparison to younger age groups. Further study of pet-related distracted driving behaviors among older drivers as well as younger populations with respect to driver safety and performance is warranted to appropriately inform the need for policy regulation on this issue. PMID:23708755

  7. Driving with pets as a risk factor for motor vehicle collisions among older drivers.

    PubMed

    Blunck, Hallie; Owsley, Cynthia; MacLennan, Paul A; McGwin, Gerald

    2013-09-01

    Increasing rates of distraction-related motor vehicle collisions (MVCs) continue to raise concerns regarding driving safety. This study sought to evaluate a novel driving-related distraction, driving with a pet, as a risk factor for MVCs among older, community dwelling adults. Two thousand licensed drivers aged 70 and older were identified, of whom 691 reported pet ownership. Comparing pet owners who did and did not drive with their pets, neither overall MVC rates (rate ratio [RR] 0.97, 95% confidence interval [CI] 0.75-1.26) nor at-fault MVC rates (RR 0.84, 95% CI 0.57-1.24) were elevated. However, those who reported always driving with a pet in the vehicle had an elevated MVC rate (RR 1.89, 95% CI 1.10-3.25), as compared to those who did not drive with a pet. The MVC rate was not increased for those reporting only sometimes or rarely driving with a pet in the vehicle. The current study demonstrates an increased risk of MVC involvement in those older drivers who always take a pet with them when they drive a vehicle. When confronted with an increased cognitive or physical workload while driving, elderly drivers in prior studies have exhibited slower cognitive performance and delayed response times in comparison to younger age groups. Further study of pet-related distracted driving behaviors among older drivers as well as younger populations with respect to driver safety and performance is warranted to appropriately inform the need for policy regulation on this issue. Published by Elsevier Ltd.

  8. Sensitivity of potential evapotranspiration estimation to the Thornthwaite and Penman-Monteith methods in the study of global drylands

    NASA Astrophysics Data System (ADS)

    Yang, Qing; Ma, Zhuguo; Zheng, Ziyan; Duan, Yawen

    2017-12-01

    Drylands are among those regions most sensitive to climate and environmental changes and human-induced perturbations. The most widely accepted definition of the term dryland is a ratio, called the Surface Wetness Index (SWI), of annual precipitation to potential evapotranspiration (PET) being below 0.65. PET is commonly estimated using the Thornthwaite (PET Th) and Penman-Monteith equations (PET PM). The present study compared spatiotemporal characteristics of global drylands based on the SWI with PET Th and PET PM. Results showed vast differences between PET Th and PET PM; however, the SWI derived from the two kinds of PET showed broadly similar characteristics in the interdecadal variability of global and continental drylands, except in North America, with high correlation coefficients ranging from 0.58 to 0.89. It was found that, during 1901-2014, global hyper-arid and semi-arid regions expanded, arid and dry sub-humid regions contracted, and drylands underwent interdecadal fluctuation. This was because precipitation variations made major contributions, whereas PET changes contributed to a much lesser degree. However, distinct differences in the interdecadal variability of semi-arid and dry sub-humid regions were found. This indicated that the influence of PET changes was comparable to that of precipitation variations in the global dry-wet transition zone. Additionally, the contribution of PET changes to the variations in global and continental drylands gradually enhanced with global warming, and the Thornthwaite method was found to be increasingly less applicable under climate change.

  9. The Label Matters: μPET Imaging of the Biodistribution of Low Molar Mass 89Zr and 18F-Labeled Poly(2-ethyl-2-oxazoline).

    PubMed

    Glassner, Mathias; Palmieri, Luca; Monnery, Bryn D; Verbrugghen, Thomas; Deleye, Steven; Stroobants, Sigrid; Staelens, Steven; Wyffels, Leonie; Hoogenboom, Richard

    2017-01-09

    Poly(2-alkyl-2-oxazoline)s (PAOx) have received increasing interest for biomedical applications. Therefore, it is of fundamental importance to gain an in-depth understanding of the biodistribution profile of PAOx. We report the biodistribution of poly(2-ethyl-2-oxazoline) (PEtOx) with a molar mass of 5 kDa radiolabeled with PET isotopes 89 Zr and 18 F. 18 F-labeled PEtOx is prepared by the strain-promoted azide-alkyne cycloaddition (SPAAC) of [ 18 F]fluoroethylazide to bicyclo[6.1.0]non-4-yne (BCN)-functionalized PEtOx as many common labeling strategies were found to be unsuccessful for PEtOx. 89 Zr-labeled PEtOx is prepared using desferrioxamine end-groups as a chelator. Five kDa PEtOx shows a significantly faster blood clearance compared to PEtOx of higher molar mass while uptake in the liver is lower, indicating a minor contribution of the liver in excretion of the 5 kDa PEtOx. While [ 18 F]-PEtOx displays a rapid and efficient clearance from the kidneys, 5 kDa [ 89 Zr]-Df-PEtOx is not efficiently cleared over the time course of the study, which is most likely caused by trapping of 89 Zr-labeled metabolites in the renal tubules and not the polymer itself, demonstrating the importance of selecting the appropriate label for biodistribution studies.

  10. Genetic and Environmental Influences on Individual Differences in Frequency of Play with Pets among Middle-Aged Men: A Behavioral Genetic Analysis

    PubMed Central

    Jacobson, Kristen C.; Hoffman, Christy L.; Vasilopoulos, Terrie; Kremen, William S.; Panizzon, Matthew S.; Grant, Michael D.; Lyons, Michael J.; Xian, Hong; Franz, Carol E.

    2014-01-01

    There is growing evidence that pet ownership and human–animal interaction (HAI) have benefits for human physical and psychological well-being. However, there may be pre-existing characteristics related to patterns of pet ownership and interactions with pets that could potentially bias results of research on HAI. The present study uses a behavioral genetic design to estimate the degree to which genetic and environmental factors contribute to individual differences in frequency of play with pets among adult men. Participants were from the ongoing longitudinal Vietnam Era Twin Study of Aging (VETSA), a population-based sample of 1,237 monozygotic (MZ) and dizygotic (DZ) twins aged 51–60 years. Results demonstrate that MZ twins have higher correlations than DZ twins on frequency of pet play, suggesting that genetic factors play a role in individual differences in interactions with pets. Structural equation modeling revealed that, according to the best model, genetic factors accounted for as much as 37% of the variance in pet play, although the majority of variance (63–71%) was due to environmental factors that are unique to each twin. Shared environmental factors, which would include childhood exposure to pets, overall accounted for <10% of the variance in adult frequency of pet play, and were not statistically significant. These results suggest that the effects of childhood exposure to pets on pet ownership and interaction patterns in adulthood may be mediated primarily by genetically-influenced characteristics. PMID:25580056

  11. Genetic and Environmental Influences on Individual Differences in Frequency of Play with Pets among Middle-Aged Men: A Behavioral Genetic Analysis.

    PubMed

    Jacobson, Kristen C; Hoffman, Christy L; Vasilopoulos, Terrie; Kremen, William S; Panizzon, Matthew S; Grant, Michael D; Lyons, Michael J; Xian, Hong; Franz, Carol E

    2012-12-01

    There is growing evidence that pet ownership and human-animal interaction (HAI) have benefits for human physical and psychological well-being. However, there may be pre-existing characteristics related to patterns of pet ownership and interactions with pets that could potentially bias results of research on HAI. The present study uses a behavioral genetic design to estimate the degree to which genetic and environmental factors contribute to individual differences in frequency of play with pets among adult men. Participants were from the ongoing longitudinal Vietnam Era Twin Study of Aging (VETSA), a population-based sample of 1,237 monozygotic (MZ) and dizygotic (DZ) twins aged 51-60 years. Results demonstrate that MZ twins have higher correlations than DZ twins on frequency of pet play, suggesting that genetic factors play a role in individual differences in interactions with pets. Structural equation modeling revealed that, according to the best model, genetic factors accounted for as much as 37% of the variance in pet play, although the majority of variance (63-71%) was due to environmental factors that are unique to each twin. Shared environmental factors, which would include childhood exposure to pets, overall accounted for <10% of the variance in adult frequency of pet play, and were not statistically significant. These results suggest that the effects of childhood exposure to pets on pet ownership and interaction patterns in adulthood may be mediated primarily by genetically-influenced characteristics.

  12. Development of PET/MRI with insertable PET for simultaneous PET and MR imaging of human brain.

    PubMed

    Jung, Jin Ho; Choi, Yong; Jung, Jiwoong; Kim, Sangsu; Lim, Hyun Keong; Im, Ki Chun; Oh, Chang Hyun; Park, Hyun-wook; Kim, Kyung Min; Kim, Jong Guk

    2015-05-01

    The purpose of this study was to develop a dual-modality positron emission tomography (PET)/magnetic resonance imaging (MRI) with insertable PET for simultaneous PET and MR imaging of the human brain. The PET detector block was composed of a 4 × 4 matrix of detector modules, each consisting of a 4 × 4 array LYSO coupled to a 4 × 4 Geiger-mode avalanche photodiode (GAPD) array. The PET insert consisted of 18 detector blocks, circularly mounted on a custom-made plastic base to form a ring with an inner diameter of 390 mm and axial length of 60 mm. The PET gantry was shielded with gold-plated conductive fabric tapes with a thickness of 0.1 mm. The charge signals of PET detector transferred via 4 m long flat cables were fed into the position decoder circuit. The flat cables were shielded with a mesh-type aluminum sheet with a thickness of 0.24 mm. The position decoder circuit and field programmable gate array-embedded DAQ modules were enclosed in an aluminum box with a thickness of 10 mm and located at the rear of the MR bore inside the MRI room. A 3-T human MRI system with a Larmor frequency of 123.7 MHz and inner bore diameter of 60 cm was used as the PET/MRI hybrid system. A custom-made radio frequency (RF) coil with an inner diameter of 25 cm was fabricated. The PET was positioned between gradient and the RF coils. PET performance was measured outside and inside the MRI scanner using echo planar imaging, spin echo, turbo spin echo, and gradient echo sequences. MRI performance was also evaluated with and without the PET insert. The stability of the newly developed PET insert was evaluated and simultaneous PET and MR images of a brain phantom were acquired. No significant degradation of the PET performance caused by MR was observed when the PET was operated using various MR imaging sequences. The signal-to-noise ratio of MR images was slightly degraded due to the PET insert installed inside the MR bore while the homogeneity was maintained. The change of gain of the 256 GAPD/scintillator elements of a detector block was <3% for 60 min, and simultaneous PET and MR images of a brain phantom were successfully acquired. Experimental results indicate that a compact and lightweight PET insert for hybrid PET/MRI can be developed using GAPD arrays and charge signal transmission method proposed in this study without significant interference.

  13. Diffuse Large B-Cell Lymphoma: Prospective Multicenter Comparison of Early Interim FLT PET/CT versus FDG PET/CT with IHP, EORTC, Deauville, and PERCIST Criteria for Early Therapeutic Monitoring

    PubMed Central

    Minamimoto, Ryogo; Fayad, Luis; Advani, Ranjana; Vose, Julie; Macapinlac, Homer; Meza, Jane; Hankins, Jordan; Mottaghy, Felix; Juweid, Malik

    2016-01-01

    Purpose To compare the performance characteristics of interim fluorine 18 (18F) fluorodeoxyglucose (FDG) positron emission tomography (PET)/computed tomography (CT) (after two cycles of chemotherapy) by using the most prominent standardized interpretive criteria (including International Harmonization Project [IHP] criteria, European Organization for Research and Treatment of Cancer [EORTC] criteria, and PET Response Criteria in Solid Tumors (PERCIST) versus those of interim 18F fluorothymidine (FLT) PET/CT and simple visual interpretation. Materials and Methods This HIPAA-compliant prospective study was approved by the institutional review boards, and written informed consent was obtained. Patients with newly diagnosed diffuse large B-cell lymphoma (DLBCL) underwent both FLT and FDG PET/CT 18–24 days after two cycles of rituximab, cyclophosphamide, doxorubicin, vincristine, and prednisone or rituximab, etoposide, prednisone, vincristine, cyclophosphamide, and doxorubicin. For FDG PET/CT interpretation, IHP criteria, EORTC criteria, PERCIST, Deauville criteria, standardized uptake value, total lesion glycolysis, and metabolic tumor volume were used. FLT PET/CT images were interpreted with visual assessment by two reviewers in consensus. The interim (after cycle 2) FDG and FLT PET/CT studies were then compared with the end-of-treatment FDG PET/CT studies to determine which interim examination and/or criteria best predicted the result after six cycles of chemotherapy. Results From November 2011 to May 2014, there were 60 potential patients for inclusion, of whom 46 patients (24 men [mean age, 60.9 years ± 13.7; range, 28–78 years] and 22 women [mean age, 57.2 years ± 13.4; range, 25–76 years]) fulfilled the criteria. Thirty-four patients had complete response, and 12 had residual disease at the end of treatment. FLT PET/CT had a significantly higher positive predictive value (PPV) (91%) in predicting residual disease than did any FDG PET/CT interpretation method (42%–46%). No difference in negative predictive value (NPV) was found between FLT PET/CT (94%) and FDG PET/CT (82%–95%), regardless of the interpretive criteria used. FLT PET/CT showed statistically higher (P < .001–.008) or similar NPVs than did FDG PET/CT. Conclusion Early interim FLT PET/CT had a significantly higher PPV than standardized FDG PET/CT–based interpretation for therapeutic response assessment in DLBCL. © RSNA, 2016 Online supplemental material is available for this article. PMID:26854705

  14. Does Antibiotic Treatment Affect the Diagnostic Accuracy of 18F-FDG PET/CT Studies in Patients with Suspected Infectious Processes?

    PubMed

    Kagna, Olga; Kurash, Marina; Ghanem-Zoubi, Nesrin; Keidar, Zohar; Israel, Ora

    2017-11-01

    18 F-FDG PET/CT plays a significant role in the assessment of various infectious processes. Patients with suspected or known sites of infection are often referred for 18 F-FDG imaging while already receiving antibiotic treatment. The current study assessed whether antibiotic therapy affected the detectability rate of infectious processes by 18 F-FDG PET/CT. Methods: A 5-y retrospective study of all adult patients who underwent 18 F-FDG PET/CT in search of a focal source of infection was performed. The presence, duration, and appropriateness of antibiotic treatment before 18 F-FDG imaging were recorded. Diagnosis of an infectious process was based on microbiologic or pathologic data as well as on clinical and radiologic follow-up. Results: Two hundred seventeen patients underwent 243 PET/CT studies in search of a focal source of infection and were included in the study. Sixty-seven studies were excluded from further analysis because of a final noninfectious etiology or lack of further follow-up or details regarding the antibiotic treatment. The final study population included 176 18 F-FDG PET/CT studies in 153 patients (107 men, 46 women; age range, 18-86 y). One hundred nineteen studies (68%) were performed in patients receiving antibiotic therapy for a range of 1-73 d. A diagnosis of infection was made in 107 true-positive cases (61%), including 63 studies (59%) in patients receiving appropriate antibiotic therapy started before the performance of the 18 F-FDG PET/CT study. There were 52 true-negative (29%) and 17 false-positive (10%) 18 F-FDG PET/CT studies. No false-negative results were found. Conclusion: 18 F-FDG PET/CT correctly identified foci of increased uptake compatible with infection in most patients, including all patients receiving appropriate antimicrobial therapy, with no false-negative cases. On the basis of the current study results, the administration of antibiotics appears to have no clinically significant impact on the diagnostic accuracy of 18 F-FDG PET/CT performed for evaluation of known or suspected infectious processes. © 2017 by the Society of Nuclear Medicine and Molecular Imaging.

  15. 18F-fluorodeoxyglucose-positron emission tomography scanning is more useful in followup than in the initial assessment of patients with Erdheim-Chester disease.

    PubMed

    Arnaud, Laurent; Malek, Zoulikha; Archambaud, Frédérique; Kas, Aurélie; Toledano, Dan; Drier, Aurélie; Zeitoun, Delphine; Cluzel, Philippe; Grenier, Philippe A; Chiras, Jacques; Piette, Jean-Charles; Amoura, Zahir; Haroche, Julien

    2009-10-01

    Erdheim-Chester disease (ECD) is a rare form of non-Langerhans' cell histiocytosis. The aim of this study was to assess the value of whole-body scanning with (18)F-fluorodeoxyglucose-positron emission tomography (FDG-PET) in a large cohort of ECD patients from a single center. We retrospectively reviewed all PET scans performed on 31 patients with ECD who were referred to our department between 2005 and 2008. PET images were reviewed by 2 independent nuclear medicine specialist physicians and were compared with other imaging modalities performed within 15 days of each PET scan. Thirty-one patients (10 women and 21 men; median age 59.5 years) underwent a total of 65 PET scans. Twenty-three patients (74%) were untreated at the time of the initial PET scan, whereas 30 of the 34 followup PET scans (88%) were performed in patients who were undergoing immunomodulatory therapy. Comparison of the initial and followup PET scans with other imaging modalities revealed that the sensitivity of PET scanning varied greatly among the different organs studied (range 4.3-100%), while the specificity remained high (range 69.2-100%). Followup PET scans were particularly helpful in assessing central nervous system (CNS) involvement, since the PET scan was able to detect an early therapeutic response of CNS lesions, even before magnetic resonance imaging showed a decrease in their size. PET scanning was also very helpful in evaluating the cardiovascular system, which is a major prognostic factor in ECD, by assessing the heart and the entire vascular tree during a single session. The results of our large, single-center, retrospective study suggest that the findings of a FDG-PET scan may be interesting in the initial assessment of patients with ECD, but its greater contribution is in followup of these patients.

  16. Advances in prostate-specific membrane antigen PET of prostate cancer.

    PubMed

    Bouchelouche, Kirsten; Choyke, Peter L

    2018-05-01

    In recent years, a large number of reports have been published on prostate-specific membrane antigen (PSMA)/PET in prostate cancer (PCa). This review highlights advances in PSMA PET in PCa during the past year. PSMA PET/computed tomography (CT) is useful in detection of biochemical recurrence, especially at low prostate-specific antigen (PSA) values. The detection rate of PSMA PET is influenced by PSA level. For primary PCa, PSMA PET/CT shows promise for tumour localization in the prostate, especially in combination with multiparametric MRI (mpMRI). For primary staging, PSMA PET/CT can be used in intermediate and high-risk PCa. Intraoperative PSMA radioligand guidance seems promising for detection of malignant lymph nodes. While the use of PSMA PET/MRI in primary localized disease is limited to high and intermediate-risk patients and localized staging, in the recurrence setting, PET/MRI can be particularly helpful when the lesions are subtle. PSMA PET/CT is superior to choline PET/CT and other conventional imaging modalities. Molecular imaging with PSMA PET continues to pave the way for personalized medicine in PCa.However, large prospective clinical studies are still needed to fully evaluate the role of PSMA PET/CT and PET/MRI in the clinical workflow of PCa.

  17. Feasibility of FDG-PET in myocarditis: Comparison to CMR using integrated PET/MRI.

    PubMed

    Nensa, Felix; Kloth, Julia; Tezgah, Ercan; Poeppel, Thorsten D; Heusch, Philipp; Goebel, Juliane; Nassenstein, Kai; Schlosser, Thomas

    2018-06-01

    Besides cardiac sarcoidosis, FDG-PET is rarely used in the diagnosis of myocardial inflammation, while cardiac MRI (CMR) is the actual imaging reference for the workup of myocarditis. Using integrated PET/MRI in patients with suspected myocarditis, we prospectively compared FDG-PET to CMR and the feasibility of integrated FDG-PET/MRI in myocarditis. A total of 65 consecutive patients with suspected myocarditis were prospectively assessed using integrated cardiac FDG-PET/MRI. Studies comprised T2-weighted imaging, late gadolinium enhancement (LGE), and simultaneous PET acquisition. Physiological glucose uptake in the myocardium was suppressed using dietary preparation. FDG-PET/MRI was successful in 55 of 65 enrolled patients: two patients were excluded due to claustrophobia and eight patients due to failed inhibition of myocardial glucose uptake. Compared with CMR (LGE and/or T2), sensitivity and specificity of PET was 74% and 97%. Overall spatial agreement between PET and CMR was κ = 0.73. Spatial agreement between PET and T2 (κ = 0.75) was higher than agreement between PET and LGE (κ = 0.64) as well as between LGE and T2 (κ = 0.56). In patients with suspected myocarditis, FDG-PET is in good agreement with CMR findings.

  18. A comparative study between evaluation methods for quality control procedures for determining the accuracy of PET/CT registration

    NASA Astrophysics Data System (ADS)

    Cha, Min Kyoung; Ko, Hyun Soo; Jung, Woo Young; Ryu, Jae Kwang; Choe, Bo-Young

    2015-08-01

    The Accuracy of registration between positron emission tomography (PET) and computed tomography (CT) images is one of the important factors for reliable diagnosis in PET/CT examinations. Although quality control (QC) for checking alignment of PET and CT images should be performed periodically, the procedures have not been fully established. The aim of this study is to determine optimal quality control (QC) procedures that can be performed at the user level to ensure the accuracy of PET/CT registration. Two phantoms were used to carry out this study: the American college of Radiology (ACR)-approved PET phantom and National Electrical Manufacturers Association (NEMA) International Electrotechnical Commission (IEC) body phantom, containing fillable spheres. All PET/CT images were acquired on a Biograph TruePoint 40 PET/CT scanner using routine protocols. To measure registration error, the spatial coordinates of the estimated centers of the target slice (spheres) was calculated independently for the PET and the CT images in two ways. We compared the images from the ACR-approved PET phantom to that from the NEMA IEC body phantom. Also, we measured the total time required from phantom preparation to image analysis. The first analysis method showed a total difference of 0.636 ± 0.11 mm for the largest hot sphere and 0.198 ± 0.09 mm for the largest cold sphere in the case of the ACR-approved PET phantom. In the NEMA IEC body phantom, the total difference was 3.720 ± 0.97 mm for the largest hot sphere and 4.800 ± 0.85 mm for the largest cold sphere. The second analysis method showed that the differences in the x location at the line profile of the lesion on PET and CT were (1.33, 1.33) mm for a bone lesion, (-1.26, -1.33) mm for an air lesion and (-1.67, -1.60) mm for a hot sphere lesion for the ACR-approved PET phantom. For the NEMA IEC body phantom, the differences in the x location at the line profile of the lesion on PET and CT were (-1.33, 4.00) mm for the air lesion and (1.33, -1.29) mm for a hot sphere lesion. These registration errors from this study were reasonable compared to the errors reported in previous studies. Meanwhile, the total time required from phantom preparation was 67.72 ± 4.50 min for the ACR-approved PET phantom and 96.78 ± 8.50 min for the NEMA IEC body phantom. When the registration errors and the lead times are considered, the method using the ACR-approved PET phantom was more practical and useful than the method using the NEMA IEC body phantom.

  19. Nondestructive Analysis of Apollo Samples by Micro-CT and Micro-XRF Analysis: A PET Style Examination

    NASA Technical Reports Server (NTRS)

    Zeigler, Ryan A.

    2014-01-01

    An integral part of any sample return mission is the initial description and classification of returned samples by the preliminary examination team (PET). The goal of a PET is to characterize and classify the returned samples, making this information available to the general research community who can then conduct more in-depth studies on the samples. A PET strives to minimize the impact their work has on the sample suite, which often limits the PET work to largely visual measurements and observations like optical microscopy. More modern techniques can also be utilized by future PET to nondestructively characterize astromaterials in a more rigorous way. Here we present our recent analyses of Apollo samples 14321 and 14305 by micro-CT and micro-XRF (respectively), assess the potential for discovery of "new" Apollo samples for scientific study, and evaluate the usefulness of these techniques in future PET efforts.

  20. Early, current and past pet ownership: associations with sensitization, bronchial responsiveness and allergic symptoms in school children.

    PubMed

    Anyo, G; Brunekreef, B; de Meer, G; Aarts, F; Janssen, N A H; van Vliet, P

    2002-03-01

    Studies have suggested that early contact with pets may prevent the development of allergy and asthma. To study the association between early, current and past pet ownership and sensitization, bronchial responsiveness and allergic symptoms in school children. A population of almost 3000 primary school children was investigated using protocols of the International Study on Asthma and Allergies in Childhood (ISAAC). Allergic symptoms were measured using the parent-completed ISAAC questionnaire. Sensitization to common allergens was measured using skin prick tests (SPT)s and/or serum immunoglobulin (Ig)E determinations. Bronchial responsiveness was tested using a hypertonic saline challenge. Pet ownership was investigated by questionnaire. Current, past and early exposure to pets was documented separately for cats, dogs, rodents and birds. The data on current, past and early pet exposure were then related to allergic symptoms, sensitization and bronchial responsiveness. Among children currently exposed to pets, there was significantly less sensitization to cat (odds ratio (OR) = 0.69) and dog (OR = 0.63) allergens, indoor allergens in general (OR = 0.64), and outdoor allergens (OR = 0.60) compared to children who never had pets in the home. There was also less hayfever (OR = 0.66) and rhinitis (OR = 0.76). In contrast, wheeze, asthma and bronchial responsiveness were not associated with current pet ownership. Odds ratios associated with past pet ownership were generally above unity, and significant for asthma in the adjusted analysis (OR = 1.85), suggesting selective avoidance in families with sensitized and/or symptomatic children. Pet ownership in the first two years of life only showed an inverse association with sensitization to pollen: OR = 0.71 for having had furry or feathery pets in general in the first two years of life, and OR = 0.73 for having had cats and/or dogs in the first two years of life, compared to not having had pets in the first two years of life. These results suggest that the inverse association between current pet ownership and sensitization and hayfever symptoms was partly due to the removal of pets in families with sensitized and/or symptomatic children. Pet ownership in the first two years of life only seemed to offer some protection against sensitization to pollen.

  1. Positron emission tomography molecular imaging of dopaminergic system in drug addiction.

    PubMed

    Hou, Haifeng; Tian, Mei; Zhang, Hong

    2012-05-01

    Dopamine (DA) is involved in drug reinforcement, but its role in drug addiction remains unclear. Positron emission tomography (PET) is the first technology used for the direct measurement of components of the dopaminergic system in the living human brain. In this article, we reviewed the major findings of PET imaging studies on the involvement of DA in drug addiction, especially in heroin addiction. Furthermore, we summarized PET radiotracers that have been used to study the role of DA in drug addiction. To investigate presynaptic function in drug addiction, PET tracers have been developed to measure DA synthesis and transport. For the investigation of postsynaptic function, several radioligands targeting dopamine one (D1) receptor and dopamine two (D2) receptor are extensively used in PET imaging studies. Moreover, we also summarized the PET imaging findings of heroin addiction studies, including heroin-induced DA increases and the reinforcement, role of DA in the long-term effects of heroin abuse, DA and vulnerability to heroin abuse and the treatment implications. PET imaging studies have corroborated the role of DA in drug addiction and increase our understanding the mechanism of drug addiction. Copyright © 2012 Wiley Periodicals, Inc.

  2. The effective dose result of 18F-FDG PET-CT paediatric patients

    NASA Astrophysics Data System (ADS)

    Hussin, D.; Said, M. A.; Ali, N. S.; Tajuddin, A. A.; Zainon, R.

    2017-05-01

    Paediatric patient received high exposure from both CT and PET examination. Automatic Exposure Control (AEC) is important in CT dose reduction. This study aimed to compare the effective dose obtained from PET-CT scanner with and without the use of AEC function. In this study, 68 patients underwent PET-CT examination without the use of AEC function, while 25 patients used the AEC function during the examination. Patients involved in this study were between 2 to 15 years old with varies of malignancies and epilepsy diseases. The effective dose obtained from PET and CT examinations was calculated based on recommendation from International Commission on Radiological Protection (ICRP) Publication 106 and ICRP publication 102. The outcome of this study shows that the radiation dose was reduced up to 20% with the use of AEC function. The mean average of effective dose result obtained from PET and CT examinations without the use of AEC and AEC function were found to be as 6.67 mSv, 6.77 mSv, 6.03mSv and 4.96 mSv respectively. Where total effective dose result of PET-CT with non-AEC and AEC were found to be 13.44 mSv and 10.99 mSv respectively. Conclusion of this study is, the installation of AEC function in PET-CT machine does play important role in CT dose reduction especially for paediatric patient.

  3. Dose Optimization in TOF-PET/MR Compared to TOF-PET/CT

    PubMed Central

    Queiroz, Marcelo A.; Delso, Gaspar; Wollenweber, Scott; Deller, Timothy; Zeimpekis, Konstantinos; Huellner, Martin; de Galiza Barbosa, Felipe; von Schulthess, Gustav; Veit-Haibach, Patrick

    2015-01-01

    Purpose To evaluate the possible activity reduction in FDG-imaging in a Time-of-Flight (TOF) PET/MR, based on cross-evaluation of patient-based NECR (noise equivalent count rate) measurements in PET/CT, cross referencing with phantom-based NECR curves as well as initial evaluation of TOF-PET/MR with reduced activity. Materials and Methods A total of 75 consecutive patients were evaluated in this study. PET/CT imaging was performed on a PET/CT (time-of-flight (TOF) Discovery D 690 PET/CT). Initial PET/MR imaging was performed on a newly available simultaneous TOF-PET/MR (Signa PET/MR). An optimal NECR for diagnostic purposes was defined in clinical patients (NECRP) in PET/CT. Subsequent optimal activity concentration at the acquisition time ([A]0) and target NECR (NECRT) were obtained. These data were used to predict the theoretical FDG activity requirement of the new TOF-PET/MR system. Twenty-five initial patients were acquired with (retrospectively reconstructed) different imaging times equivalent for different activities on the simultaneous PET/MR for the evaluation of clinically realistic FDG-activities. Results The obtained values for NECRP, [A]0 and NECRT were 114.6 (± 14.2) kcps (Kilocounts per second), 4.0 (± 0.7) kBq/mL and 45 kcps, respectively. Evaluating the NECRT together with the phantom curve of the TOF-PET/MR device, the theoretical optimal activity concentration was found to be approximately 1.3 kBq/mL, which represents 35% of the activity concentration required by the TOF-PET/CT. Initial evaluation on patients in the simultaneous TOF-PET/MR shows clinically realistic activities of 1.8 kBq/mL, which represent 44% of the required activity. Conclusion The new TOF-PET/MR device requires significantly less activity to generate PET-images with good-to-excellent image quality, due to improvements in detector geometry and detector technologies. The theoretically achievable dose reduction accounts for up to 65% but cannot be fully translated into clinical routine based on the coils within the FOV and MR-sequences applied at the same time. The clinically realistic reduction in activity is slightly more than 50%. Further studies in a larger number of patients are needed to confirm our findings. PMID:26147919

  4. Change in chemotherapy during concurrent radiation followed by surgery after a suboptimal positron emission tomography response to induction chemotherapy improves outcomes for locally advanced esophageal adenocarcinoma.

    PubMed

    Ku, Geoffrey Y; Kriplani, Anuja; Janjigian, Yelena Y; Kelsen, David P; Rusch, Valerie W; Bains, Manjit; Chou, Joanne; Capanu, Marinela; Wu, Abraham J; Goodman, Karyn A; Ilson, David H

    2016-07-01

    A positron emission tomography (PET) scan after induction chemotherapy before preoperative chemoradiation and surgery for esophageal adenocarcinoma predicts outcomes. Some patients with progression on PET after induction chemotherapy had long-term overall survival (OS) when they were changed to alternative chemotherapy during radiation. This study retrospectively reviewed esophageal adenocarcinoma patients who received induction chemotherapy and chemoradiation before planned surgery; all had undergone a PET scan before and after induction chemotherapy. There were 201 patients, and 113 (56%) were PET responders (≥35% decrease in the maximum standardized uptake value of the tumor). All PET responders received the same chemotherapy during radiation, whereas 38 of the 88 PET nonresponders (43%) changed chemotherapy. Among the 152 patients who underwent surgery, the pathologic complete response rate was 15% for PET responders and 3% for PET nonresponders who did not change chemotherapy (P = .046). The median progression-free survival (PFS; 18.9 vs 10.0 months, P < 0.01) and OS (37 vs 25.3 months, P = .02) were significantly better for PET responders versus PET nonresponders who did not change chemotherapy. The median PFS for PET nonresponders who changed chemotherapy was 17.9 months, and it was superior to the median PFS for PET nonresponders who did not change chemotherapy (P = .01). For PET nonresponders, the 5-year OS rates were 37% for those who changed chemotherapy and 25% for those who did not change chemotherapy (P = .18). A PET scan after induction chemotherapy predicts outcomes for locally advanced esophageal adenocarcinoma patients who undergo chemoradiation and surgery. The median PFS is improved, and trends toward improved OS appear possible in PET nonresponders who change chemotherapy during radiation. The fully accrued Cancer and Leukemia Group B 80803 study (NCT01333033) is evaluating this strategy. Cancer 2016;122:2083-90. © 2016 American Cancer Society. © 2016 American Cancer Society.

  5. Evaluation of dissemination studies with FDG whole-body positron emission tomography in patients with suspected metastatic tumours of brain and spine.

    PubMed

    Go, K G; Pruim, J; Que, T H; Vaalburg, W; Haaxma-Reiche, H

    2000-01-01

    In the preoperative diagnosis of malignant brain tumours there is often uncertainty regarding their metastatic or primary nature, requiring dissemination studies. Currently FDG-wbPET is being used for the efficient detection of systemic tumours. It therefore may become a substitute for the conventional dissemination studies if it allows an earlier diagnosis. In this descriptive and preliminary study a population of 14 patients with suspected or proven metastatic lesions, [18F]-fluoro-2-deoxy-D-glucose whole body positron emission tomography (FDG-wbPET) was conducted and verified by additional conventional dissemination studies. FINDINGS AND THEIR INTERPRETATION: The entire series of dissemination studies required an average of 30 days with a range of 4-73 days. The FDG-wbPET was corroborated by the other dissemination studies in 10 of the 14 patients. In 7 of these 10 patients both PET and dissemination studies showed systemic abnormal findings, but in one case the presence of high pulmonary activity on the FDG-wbPET and the abnormal findings on the chest X-rays proved to be Aspergillus infection at autopsy. In the other 2 cases the negative PET findings corresponded to the absence of systemic dissemination. In 5 cases there was disagreement of the results of the FDG-wbPET with other evidence, among which there were 2 cases of glioblastoma in which systemic metastases were most unlikely, and the foci of activity on the FDG-wbPET had to be considered as false positives. In the remaining 3 cases the systemic presence of high activity on the FDG-wbPET indicated the systemic presence of tumour, whereas the other dissemination studies disclosed no tumour. The results warrant the use of FDG-wbPET as a screening method for the search of metastases, allowing other studies to be focussed on the lesion. But from the cost/benefit point of view this would make the method less suitable as a substitute for dissemination studies in general, although it may speed up the diagnostic process.

  6. Inherited pancreatic endocrine tumor syndromes: advances in molecular pathogenesis, diagnosis, management and controversies

    PubMed Central

    Jensen, Robert T.; Berna, Marc J.; Bingham, David B; Norton, Jeffrey A.

    2008-01-01

    Pancreatic endocrine tumors (PETs) can occur in as part of four inherited disorders including: Multiple Endocrine Neoplasia type 1 (MEN1), von Hippel-Lindau disease (VHL), neurofibromatosis 1(NF-1) [von Recklinghausen’s disease] and the tuberous sclerosis complex (TSC). The relative frequency with which patients with these disorders develop PETs is MEN1>VHL>NF-1>TSC. Over the last few years there have been major advances in the understanding of the genetics and molecular pathogenesis of these disorders as well in the localization, medical and surgical treatment of the PETs in these patients. The study of the PETs in these disorders has not only provided insights into the possible pathogenesis of sporadic PETs, but have also presented a number of unique management and treatment issues, some of which are applicable to patients with sporadic PETs. Therefore the study of PETs in these uncommon disorders has provided valuable insights that in many cases are applicable to the general group of patients with sporadic PETs. In this article these areas are briefly reviewed as well as the current state of knowledge of the PETs in these disorders and the controversies that exist in their management are briefly summarized and discussed. PMID:18798544

  7. Comparison of 18F SPECT with PET in myocardial imaging: a realistic thorax-cardiac phantom study.

    PubMed

    Knešaurek, Karin; Machac, Josef

    2006-10-31

    Positron emission tomography (PET) imaging with fluorine-18 (18F) Fluorodeoxyglucose (FDG) and flow tracer such as Rubidium-82 (82Rb) is an established method for evaluating an ischemic but viable myocardium. However, the high cost of PET imaging restricts its wider clinical use. Therefore, less expensive 18F FDG single photon emission computed tomography (SPECT) imaging has been considered as an alternative to 18F FDG PET imaging. The purpose of the work is to compare SPECT with PET in myocardial perfusion/viability imaging. A nonuniform RH-2 thorax-heart phantom was used in the SPECT and PET acquisitions. Three inserts, 3 cm, 2 cm and 1 cm in diameter, were placed in the left ventricular (LV) wall to simulate infarcts. The phantom acquisition was performed sequentially with 7.4 MBq of 18F and 22.2 MBq of Technetium-99m (99mTc) in the SPECT study and with 7.4 MBq of 18F and 370 MBq of 82Rb in the PET study. SPECT and PET data were processed using standard reconstruction software provided by vendors. Circumferential profiles of the short-axis slices, the contrast and viability of the inserts were used to evaluate the SPECT and PET images. The contrast for 3 cm, 2 cm and 1 cm inserts were for 18F PET data, 1.0 +/- 0.01, 0.67 +/- 0.02 and 0.25 +/- 0.01, respectively. For 82Rb PET data, the corresponding contrast values were 0.61 +/- 0.02, 0.37 +/- 0.02 and 0.19 +/- 0.01, respectively. For 18F SPECT the contrast values were, 0.31 +/- 0.03 and 0.20 +/- 0.05 for 3 cm and 2 cm inserts, respectively. For 99mTc SPECT the contrast values were, 0.63 +/- 0.04 and 0.24 +/- 0.05 for 3 cm and 2 cm inserts respectively. In SPECT, the 1 cm insert was not detectable. In the SPECT study, all three inserts were falsely diagnosed as "viable", while in the PET study, only the 1 cm insert was diagnosed falsely "viable". For smaller defects the 99mTc/18F SPECT imaging cannot entirely replace the more expensive 82Rb/18F PET for myocardial perfusion/viability imaging, due to poorer image spatial resolution and poorer defect contrast.

  8. Physical examination tests of the shoulder: a systematic review and meta-analysis of diagnostic test performance.

    PubMed

    Gismervik, Sigmund Ø; Drogset, Jon O; Granviken, Fredrik; Rø, Magne; Leivseth, Gunnar

    2017-01-25

    Physical examination tests of the shoulder (PETS) are clinical examination maneuvers designed to aid the assessment of shoulder complaints. Despite more than 180 PETS described in the literature, evidence of their validity and usefulness in diagnosing the shoulder is questioned. This meta-analysis aims to use diagnostic odds ratio (DOR) to evaluate how much PETS shift overall probability and to rank the test performance of single PETS in order to aid the clinician's choice of which tests to use. This study adheres to the principles outlined in the Cochrane guidelines and the PRISMA statement. A fixed effect model was used to assess the overall diagnostic validity of PETS by pooling DOR for different PETS with similar biomechanical rationale when possible. Single PETS were assessed and ranked by DOR. Clinical performance was assessed by sensitivity, specificity, accuracy and likelihood ratio. Six thousand nine-hundred abstracts and 202 full-text articles were assessed for eligibility; 20 articles were eligible and data from 11 articles could be included in the meta-analysis. All PETS for SLAP (superior labral anterior posterior) lesions pooled gave a DOR of 1.38 [1.13, 1.69]. The Supraspinatus test for any full thickness rotator cuff tear obtained the highest DOR of 9.24 (sensitivity was 0.74, specificity 0.77). Compression-Rotation test obtained the highest DOR (6.36) among single PETS for SLAP lesions (sensitivity 0.43, specificity 0.89) and Hawkins test obtained the highest DOR (2.86) for impingement syndrome (sensitivity 0.58, specificity 0.67). No single PETS showed superior clinical test performance. The clinical performance of single PETS is limited. However, when the different PETS for SLAP lesions were pooled, we found a statistical significant change in post-test probability indicating an overall statistical validity. We suggest that clinicians choose their PETS among those with the highest pooled DOR and to assess validity to their own specific clinical settings, review the inclusion criteria of the included primary studies. We further propose that future studies on the validity of PETS use randomized research designs rather than the accuracy design relying less on well-established gold standard reference tests and efficient treatment options.

  9. Neutering of cats and dogs in Ireland; pet owner self-reported perceptions of enabling and disabling factors in the decision to neuter

    PubMed Central

    Devitt, Catherine; Downes, Marie T.; More, Simon J.

    2015-01-01

    Background. Failure among pet owners to neuter their pets results in increased straying and overpopulation problems. Variations in neutering levels can be explained by cultural differences, differences in economic status in rural and urban locations, and owner perceptions about their pet. There are also differences between male and female pet owners. There is no research pertaining to Irish pet owner attitudes towards neutering their pets. This paper identified the perceptions of a sample of Irish cat and dog owners that influenced their decisions on pet neutering. Methods. This study was conducted using social science (qualitative) methods, including an interview-administered survey questionnaire and focus group discussions. Data was coded and managed using Nvivo 8 qualitative data analysis software. Results. Focus groups were conducted with 43 pet (cats and dogs) owners. Two major categories relating to the decision to neuter were identified: (1) enabling perceptions in the decision to neuter (subcategories were: controlling unwanted pet behaviour; positive perceptions regarding pet health and welfare outcomes; perceived owner responsibility; pet function; and the influence of veterinary advice), and (2) disabling perceptions in the decision to neuter (subcategories were: perceived financial cost of neutering; perceived adequacy of existing controls; and negative perceptions regarding pet health and welfare outcomes). Discussion. Pet owner sense of responsibility and control are two central issues to the decision to neuter their pets. Understanding how pet owners feel about topics such as pet neutering, can help improve initiatives aimed at emphasising the responsibility of population control of cats and dogs. PMID:26312187

  10. Pet ownership and older women: the relationships among loneliness, pet attachment support, human social support, and depressed mood.

    PubMed

    Krause-Parello, Cheryl A

    2012-01-01

    Pets can play a positive role in the both the physical and psychological health of older adults. This cross sectional study investigated the relationships among loneliness, pet attachment support, human social support, and depressed mood in a convenience sample of 159 pet-owning older women residing in the community. Participants completed loneliness, pet attachment support, human social support, and depressed mood scales. The results supported significant relationships between loneliness, pet attachment support, human social support, and depressed mood. No relationship was found between human social support and depressed mood. Pet attachment support, but not human social support, influenced the relationship between loneliness and depressed mood indicating the importance of pet attachment as a greater form of support in this sample. Clinical and social implications for nurses working with the geriatric population were identified and discussed. Copyright © 2012 Mosby, Inc. All rights reserved.

  11. Effect of household pet ownership on infant immune response and subsequent sensitization

    PubMed Central

    Simpson, Angela

    2010-01-01

    Sensitization to pets is a major risk factor for asthma. There are many reports on the relationship between household pets, sensitization to the pet, and sensitization to other allergens, often with conflicting results. Pet ownership is not random, and household pets are associated with exposures other than pet allergens. We will review some of the evidence regarding the effects of household pets on infant immune responses, focusing on data from birth cohort studies. It remains unclear precisely why some children develop specific sensitizations to pets whilst others do not in the face of equivalent exposures, but it is likely to be due to gene-environment interactions. Further long-term follow-up of children in whom neonatal and infant immune responses have been measured is necessary to understand how these events occur and how they relate to subsequent disease. PMID:21437047

  12. The ADNI PET Core: 2015

    PubMed Central

    Jagust, William J.; Landau, Susan M.; Koeppe, Robert A.; Reiman, Eric M.; Chen, Kewei; Mathis, Chester A.; Price, Julie C.; Foster, Norman L.; Wang, Angela Y.

    2015-01-01

    INTRODUCTION This paper reviews the work done in the ADNI PET core over the past 5 years, largely concerning techniques, methods, and results related to amyloid imaging in ADNI. METHODS The PET Core has utilized [18F]florbetapir routinely on ADNI participants, with over 1600 scans available for download. Four different laboratories are involved in data analysis, and have examined factors such as longitudinal florbetapir analysis, use of FDG-PET in clinical trials, and relationships between different biomarkers and cognition. RESULTS Converging evidence from the PET Core has indicated that cross-sectional and longitudinal florbetapir analyses require different reference regions. Studies have also examined the relationship between florbetapir data obtained immediately after injection, which reflects perfusion, and FDG-PET results. Finally, standardization has included the translation of florbetapir PET data to a centiloid scale. CONCLUSION The PET Core has demonstrated a variety of methods for standardization of biomarkers such as florbetapir PET in a multicenter setting. PMID:26194311

  13. [Pet ownership and health status of pets from immunocompromised children, with emphasis in zoonotic diseases].

    PubMed

    Abarca V, Katia; López Del P, Javier; Peña D, Anamaría; López G, J Carlos

    2011-06-01

    To characterize pet ownership and pet health status in families of immunocompromised (IS) children, with emphasis in zoonotic diseases. Families of IS children from two hospitals in Santiago, Chile, were interviewed and their pets were evaluated by veterinary examination, coproparasitologic and skin dermatophytes test. In specific cases, other laboratory tests were performed in IS children or their relatives. 47 out of 70 contacted families had pets, 42 participated in the study. Several risk factors for IS children were observed, as having a turtle as a pet and to clean cat or turtle faeces. Lack of adequate veterinary control, immunizations and deparasitation of pets were observed. Some animals showed zoonotic diseases or agents, as Brucella canis, Cryptosporidium sp, Giardia intestinalis, Toxocara canis and scabies. 44% of dogs had ticks and 37% had fleas, both potential vectors of infections. Our results suggest that policies to provide safer pet contact in IS children are needed.

  14. Estimation of Hoffman-Lauritzen parameters from nonisothermal crystallization kinetics of PET/MWCNT nanocomposites

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gaonkar, Amita, E-mail: ami.gaonkar@gmail.com; Murudkar, Vrishali, E-mail: vru0077@gmail.com; Deshpande, V. D., E-mail: vindesh2@rediffmail.com

    2016-05-06

    Polyethylene terephthalate (PET) and Nucleated PET/ multi-walled carbon nanotubes (MWCNTs) nanocomposites with different MWCNTs loadings were prepared by melt compounding. The influence of the addition of MWCNTs and precipitated PET (p-PET) on the morphology and thermal properties of the nanocomposites was investigated. From Transmission Electronic Microscopy (TEM) and Wide angle X-Ray diffraction (WAXD) study, it can be clearly seen that nanocomposites with low MWCNTs contents (0.1 wt. %) get better MWCNTs dispersion than higher MWCNT loading. Comparing with PET, nucleated PET nanocomposite with 0.1% MWCNT loading shows higher value of Lauritzen-Hoffman parameters U* and Kg evaluated using the differential isoconversionalmore » method. Crystallization regime transition temperature range shifts to higher temperature (208°C - 215°C) for nanocomposites. The presence of p-PET in addition of MWCNT, which act as good nucleating agent, enhanced the crystallization of PET through heterogeneous nucleation.« less

  15. Estimation of Hoffman-Lauritzen parameters from nonisothermal crystallization kinetics of PET/MWCNT nanocomposites

    NASA Astrophysics Data System (ADS)

    Gaonkar, Amita; Murudkar, Vrishali; Deshpande, V. D.

    2016-05-01

    Polyethylene terephthalate (PET) and Nucleated PET/ multi-walled carbon nanotubes (MWCNTs) nanocomposites with different MWCNTs loadings were prepared by melt compounding. The influence of the addition of MWCNTs and precipitated PET (p-PET) on the morphology and thermal properties of the nanocomposites was investigated. From Transmission Electronic Microscopy (TEM) and Wide angle X-Ray diffraction (WAXD) study, it can be clearly seen that nanocomposites with low MWCNTs contents (0.1 wt. %) get better MWCNTs dispersion than higher MWCNT loading. Comparing with PET, nucleated PET nanocomposite with 0.1% MWCNT loading shows higher value of Lauritzen-Hoffman parameters U* and Kg evaluated using the differential isoconversional method. Crystallization regime transition temperature range shifts to higher temperature (208°C - 215°C) for nanocomposites. The presence of p-PET in addition of MWCNT, which act as good nucleating agent, enhanced the crystallization of PET through heterogeneous nucleation.

  16. Photophysical and photochemical effects of UV and VUV photo-oxidation and photolysis on PET and PEN

    NASA Astrophysics Data System (ADS)

    Morgan, Andrew

    Polyethylene Terephthalate (PET) is a widely used polymer in the bottling, packaging, and clothing industry. In recent years an increasing global demand for PET has taken place due to the Solar Disinfection (SODIS) process. SODIS is a method of sterilizing fresh water into drinkable water. The PET bottles are used in the process to contain the water during solar irradiation due to its highly transparent optical property. Alongside PET, polyethylene 2,6-napthalate (PEN) is used in bottling and flexible electronic applications. The surface of PEN would need to be modified to control the hydrophilicity and the interaction it exudes as a substrate. The UV light absorption properties of PET and PEN are of great importance for many applications, and thus needs to be studied along with its photochemical resistance. The optical and chemical nature of PET was studied as it was treated by UV photo-oxidation, photo-ozonation, and photolysis under atmospheric pressure. Another investigation was also used to study PEN and PET as they are treated by vacuum UV (VUV) photo-oxidation, VUV photolysis, and remote oxygen reactions. The extent of the photoreactions' effect into the depth of the polymers is examined as treatment conditions are changed. The different experimental methods established the rate of several competing photoreactions on PET and PEN during irradiance, and their effect on the optical quality of the polymers.

  17. Academic time at a level 1 trauma center: no resident, no problem?

    PubMed

    Matsushima, Kazuhide; Dickinson, Rebecca M; Schaefer, Eric W; Armen, Scott B; Frankel, Heidi L

    2012-01-01

    Globally, the compliance of resident work-hour restrictions has no impact on trauma outcome. However, the effect of protected education time (PET), during which residents are unavailable to respond to trauma patients, has not been studied. We hypothesized that PET has no impact on the outcome of trauma patients. We conducted a retrospective review of relevant patients at an academic level I trauma center. During PET, a trauma attending and advanced practice providers (APPs) responded to trauma activations. PGY1, 3, and 4 residents were also available at all other times. The outcome of new trauma patient activations during Thursday morning 3-hours resident PET was compared with same time period on other weekdays (non-PET) using a univariate and multivariate analysis. From January 2005 to April 2010, a total of 5968 trauma patients were entered in the registry. Of these, 178 patients (2.98%) were included for study (37 PET and 141 non-PET). The mean injury severity score (ISS) was 16.2. Although no significant difference were identified in mortality, complications, or length of stay (LOS), we do see that length of emergency department stay (ED-LOS) tends to be longer during PET, although not significantly (314 vs 381 minutes, p = 0.74). On the multiple logistic regression model, PET was not a significant factor of complications, LOS, or ED-LOS. Few trauma activations occur during PET. New trauma activations can be staffed safely by trauma activations and APPs. However, there could be some delays in transferring patients to appropriate disposition. Additional study is required to determine the effect of PET on existing trauma inpatients. Copyright © 2012 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.

  18. Sustainable carbothermal reduction and nitridation of Malaysian ilmenite by polyethylene terephthalate and coal

    NASA Astrophysics Data System (ADS)

    Ahmadi, Eltefat; Hamid, Sheikh Abdul Rezan Sheikh Abdul; Hussin, Hashim; Baharun, Norlia; Ariffin, Kamar Shah; Ramakrishnan, Sivakumar; Fauzi, M. N. Ahmad; Ismail, Hanafi

    2017-07-01

    In this paper, the carbothermal reduction and nitridation (CTRN) of Malaysian ilmenite has been studied as a part of crucial steps involved in reduction and subsequent chlorination processes for synthesizing titanium tetrachloride (TiCl4) from nitrided Malaysian ilmenite concentrates. In CTRN, waste plastics such as polyethylene terephthalate (PET) could be utilized as an alternative source of carbon reductant. In this study, titanium oxycarbonitride (TiOxCyNz) separated from iron (Fe) phase was synthesized by non-isothermal CTRN of Malaysian ilmenite under H2-N2 atmosphere by utilizing a mixture of Sarawak Mukah-Balingan coal and PET as reducing agents in a horizontal tube furnace. Experiments have been carried out in the temperature range of 1150-1250°C for 3 hours with various ratios of PET to coal (25 wt.% PET, 50 wt.% PET, and 75 wt.% PET). X-ray diffraction (XRD), X-ray fluorescence (XRF), scanning electron microscopy (SEM) and energy dispersive X-ray (EDX) methods of analysis were conducted to assess the microstructures and chemical compositions of the unreduced and reduced samples. The results indicated that utilizing PET had a significant effect on iron separation from titanium oxycarbonitride (TiO0.02C0.13N0.85) at 1250°C with a mixture of 75 wt.% PET. Furthermore, XRD and SEM studies demonstrated that with increasing PET weight ratio in the mixtures, the rate of conversion increased and a low-carbon TiOxCyNz with minimal intermediate titanium sub-oxides was synthesized. The method of applying PET as potential reductant for CTRN of ilmenite has beneficial side effects in sustainable recycling of waste PET.

  19. [18F]FDOPA PET as an Endophenotype for Parkinson’s Disease Linkage Studies

    PubMed Central

    Racette, Brad A.; Good, Laura; Antenor, Jo Ann; McGee-Minnich, Lori; Moerlein, Stephen M.; Videen, Tom O.; Perlmutter, Joel S.

    2008-01-01

    Parkinson Disease (PD) is a late onset disorder with age-dependent penetrance that may confound genetic studies since affected individuals may not demonstrate clinical manifestations at the time of evaluation. The use of endophenotypes, biologic surrogates for clinical disease diagnoses, may permit more accurate classification of at-risk subjects. Positron emission tomography (PET) measurements of 6-[18F]fluorodopa ([18F]FDOPA) uptake indicate nigrostriatal neuronal integrity and may provide a useful endophenotype for PD linkage studies. We performed [18F]FDOPA PET in 11 members of a large, multi-incident Amish family with PD, 24 normals and 48 people with clinically definite idiopathic PD (PD controls). Clinical diagnoses in the Amish were clinically definite PD in four, clinically probable in one, clinically possible in five, and normal in one. Abnormal [18F]FDOPA posterior putamen uptake was defined as less than three standard deviations below the normal mean. The criteria were applied to the Amish sample to determine a PET endophenotype for each. We performed genetic simulations using SLINK to model the effect phenoconversion with the PET endophenotype had on logarithm of odds (LOD) scores. PET endophenotype confirmed the status of two clinically definite subjects. Two clinically definite Amish PD subjects had normal PETs. Two possible PD were converted to “PET definite PD”. The remainder had normal PETs. The average maximum LOD score with the pre-PET was 6.14±0.84. Simulating phenoconversion of subjects with unknown phenotypes increased the LOD score to 7.36±1.23. The [18F]FDOPA PET endophenotype permits phenoconversion in multi-incident PD families and may increase LOD score accuracy and power of an informative pedigree. PMID:16528749

  20. Prognostic value of interim FDG-PET in R-CHOP-treated diffuse large B-cell lymphoma: Systematic review and meta-analysis.

    PubMed

    Adams, Hugo J A; Kwee, Thomas C

    2016-10-01

    This study aimed to systematically review and meta-analyze the prognostic value of interim (18)F-fluoro-2-deoxy-d-glucose positron emission tomography (FDG-PET) in diffuse large B-cell lymphoma (DLBCL) patients treated with rituximab, cyclophosphamide, doxorubicin, vincristine, and prednisolone (R-CHOP). MEDLINE and EMBASE were systematically searched for suitable studies. Included studies were methodologically appraised, and results were summarized both descriptively and meta-analytically. Nine studies, comprising a total of 996 R-CHOP-treated DLBCL patients, were included. Overall, studies were of moderate methodological quality. The area under the summary receiver operating curve (AUC) of interim FDG-PET in predicting treatment failure and death were 0.651 and 0.817, respectively. There was no heterogeneity in diagnostic odds ratios across available studies (I(2)=0.0%). At multivariable analysis, 2 studies reported interim FDG-PET to have independent prognostic value in addition to the International Prognostic Index (IPI) in predicting treatment failure, whereas 3 studies reported that this was not the case. One study reported interim FDG-PET to have independent prognostic value in addition to the IPI in predicting death, whereas 2 studies reported that this was not the case. In conclusion, interim FDG-PET in R-CHOP-treated DLBCL has some correlation with outcome, but its prognostic value is homogeneously suboptimal across studies and it has not consistently proven to surpass the prognostic potential of the IPI. Moreover, there is a lack of studies that compared interim FDG-PET to the recently developed and superior National Comprehensive Cancer Network-IPI. Therefore, at present there is no scientific base to support the clinical use of interim FDG-PET in R-CHOP-treated DLBCL. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  1. Parametric PET/MR Fusion Imaging to Differentiate Aggressive from Indolent Primary Prostate Cancer with Application for Image-Guided Prostate Cancer Biopsies

    DTIC Science & Technology

    2013-10-01

    AD_________________ Award Number: W81XWH-12-1-0597 TITLE: Parametric PET /MR Fusion Imaging to...Parametric PET /MR Fusion Imaging to Differentiate Aggressive from Indolent Primary Prostate Cancer with Application for Image-Guided Prostate Cancer Biopsies...The study investigates whether fusion PET /MRI imaging with 18F-choline PET /CT and diffusion-weighted MRI can be successfully applied to target prostate

  2. Metabolic impact of partial volume correction of [18F]FDG PET-CT oncological studies on the assessment of tumor response to treatment.

    PubMed

    Stefano, A; Gallivanone, F; Messa, C; Gilardi, M C; Gastiglioni, I

    2014-12-01

    The aim of this work is to evaluate the metabolic impact of Partial Volume Correction (PVC) on the measurement of the Standard Uptake Value (SUV) from [18F]FDG PET-CT oncological studies for treatment monitoring purpose. Twenty-nine breast cancer patients with bone lesions (42 lesions in total) underwent [18F]FDG PET-CT studies after surgical resection of breast cancer primitives, and before (PET-II) chemotherapy and hormone treatment. PVC of bone lesion uptake was performed on the two [18F]FDG PET-CT studies, using a method based on Recovery Coefficients (RC) and on an automatic measurement of lesion metabolic volume. Body-weight average SUV was calculated for each lesion, with and without PVC. The accuracy, reproducibility, clinical feasibility and the metabolic impact on treatment response of the considered PVC method was evaluated. The PVC method was found clinically feasible in bone lesions, with an accuracy of 93% for lesion sphere-equivalent diameter >1 cm. Applying PVC, average SUV values increased, from 7% up to 154% considering both PET-I and PET-II studies, proving the need of the correction. As main finding, PVC modified the therapy response classification in 6 cases according to EORTC 1999 classification and in 5 cases according to PERCIST 1.0 classification. PVC has an important metabolic impact on the assessment of tumor response to treatment by [18F]FDG PET-CT oncological studies.

  3. Relationship Between the Elevated Muscle FDG Uptake in the Distal Upper Extremities on PET/CT Scan and Prescan Utilization of Mobile Devices in Young Patients.

    PubMed

    Bai, Xia; Wang, Xuemei; Zhuang, Hongming

    2018-03-01

    It is common to notice increased FDG activity in the muscles of the forearms or hands on PET/CT images. The purpose of this study was to determine relationship between the prevalence of increased FDG activity in the forearms or hands and using mobile devices prior to the FDG PET/CT study. A total of 443 young patients with ages between 5 and 19 years who underwent FDG PET/CT scan were included in this retrospective analysis. All patients had FDG PET/CT with their arms within the field of views. The images were reviewed for elevated activity in the muscles of the distal upper extremities (DUEs), which include forearms and hands. The preimaging questionnaire/interview records regarding using mobile devices prior to FDG PET/CT were also reviewed and compared with the imaging findings. Most patients (72.0% [319/443]) used mobile devices more than 60 minutes in the period of 24 hours prior to the FDG PET/CT study. Elevated uptake in the muscles in the DUEs was observed in 38.6% (123/319) of these patients. In contrast, among 124 patients who did not use the mobile devices or used the mobile device minimally prior to the study, only 6.5% (8/124) of them had elevated FDG activity in the DUEs. The difference persisted following stratification analysis for sex, age, and serum glucose level in our patient population. Increased FDG uptake in the muscles of the DUEs in young patients is commonly seen in those who used mobile devices prior to PET/CT study. Recommendation should be considered to reduce using mobile devices prior to FDG PET/CT study in young patient population.

  4. Characterization in humans of 18F-MNI-444, a PET radiotracer for brain adenosine 2A receptors.

    PubMed

    Barret, Olivier; Hannestad, Jonas; Vala, Christine; Alagille, David; Tavares, Adriana; Laruelle, Marc; Jennings, Danna; Marek, Ken; Russell, David; Seibyl, John; Tamagnan, Gilles

    2015-04-01

    PET with selective adenosine 2A receptor (A2A) radiotracers can be used to study a variety of neurodegenerative and neuropsychiatric disorders in vivo and to support drug-discovery studies targeting A2A. The aim of this study was to describe the first in vivo evaluation of (18)F-MNI-444, a novel PET radiotracer for imaging A2A, in healthy human subjects. Ten healthy human volunteers were enrolled in this study; 6 completed the brain PET studies and 4 participated in the whole-body PET studies. Arterial blood was collected for invasive kinetic modeling of the brain PET data. Noninvasive methods of data quantification were also explored. Test-retest reproducibility was evaluated in 5 subjects. Radiotracer distribution and dosimetry was determined using serial whole-body PET images acquired over 6 h post-radiotracer injection. Urine samples were collected to calculate urinary excretion. After intravenous bolus injection, (18)F-MNI-444 rapidly entered the brain and displayed a distribution consistent with known A2A densities in the brain. Binding potentials ranging from 2.6 to 4.9 were measured in A2A-rich regions, with an average test-retest variability of less than 10%. The estimated whole-body radiation effective dose was approximately 0.023 mSv/MBq. (18)F-MNI-444 is a useful PET radiotracer for imaging A2A in the human brain. The superior in vivo brain kinetic properties of (18)F-MNI-444, compared with previously developed A2A radiotracers, provide the opportunity to foster global use of in vivo A2A PET imaging in neuroscience research. © 2015 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  5. Interobserver agreement of interim and end-of-treatment 18F-FDG PET/CT in diffuse large B-cell lymphoma (DLBCL): impact on clinical practice and trials.

    PubMed

    Burggraaff, Coreline N; Cornelisse, Alexander C; Hoekstra, Otto S; Lugtenburg, Pieternella J; de Keizer, Bart; Arens, Anne I J; Celik, Filiz; Huijbregts, Julia E; De Vet, Henrica C W; Zijlstra, Josee M

    2018-05-04

    We aimed to assess the interobserver agreement of Interim PET (I-PET) and End-of-Treatment PET (EoT-PET) using the Deauville 5-point scale (DS) in first-line DLBCL patients. Methods: I-PET and EoT-PET scans of DLBCL patients were performed in the HOVON84 study (2007-2012), an international multicenter randomized controlled trial. Patients received R-CHOP14 and were randomized to receive rituximab intensification in the first 4 cycles or not. I-PET was made after 4 cycles (for observational purposes), and EoT-PET scan after 6 or 8 cycles. Two independent central reviewers retrospectively scored all scans according to the DS-system, blinded to clinical outcomes. Results were dichotomised as 'negative' (DS: 1-3) or 'positive' (DS: 4-5). Besides percentage overall agreement we calculated agreement for positive and negative scores, expressed as positive agreement (PA) and negative agreement (NA), respectively. Results: 465 I-PET and 457 EoT-PET scans were centrally reviewed; baseline 18 F-FDG PET(/CT) was available in 75-77%, and CT in the remaining cases. Percentage overall agreement for I-PET and EoT-PET were 87.7% and 91.7% ( P =0.049), with NA of 92.0% and 95.0% ( P =0.091), and PA of 73.7% and 76.3% ( P =0.656), respectively. Conclusion: Interobserver agreement using DS in DLBCL patients in I-PET and EoT-PET yields high overall and negative agreement. The lower positive agreement suggests that EoT-PET/CT treatment evaluation in daily practice and I-PET adapted trials may benefit from dual reads and central review, respectively. Copyright © 2018 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  6. NEMA NU 4-2008 validation and applications of the PET-SORTEO Monte Carlo simulations platform for the geometry of the Inveon PET preclinical scanner

    NASA Astrophysics Data System (ADS)

    Boisson, F.; Wimberley, C. J.; Lehnert, W.; Zahra, D.; Pham, T.; Perkins, G.; Hamze, H.; Gregoire, M.-C.; Reilhac, A.

    2013-10-01

    Monte Carlo-based simulation of positron emission tomography (PET) data plays a key role in the design and optimization of data correction and processing methods. Our first aim was to adapt and configure the PET-SORTEO Monte Carlo simulation program for the geometry of the widely distributed Inveon PET preclinical scanner manufactured by Siemens Preclinical Solutions. The validation was carried out against actual measurements performed on the Inveon PET scanner at the Australian Nuclear Science and Technology Organisation in Australia and at the Brain & Mind Research Institute and by strictly following the NEMA NU 4-2008 standard. The comparison of simulated and experimental performance measurements included spatial resolution, sensitivity, scatter fraction and count rates, image quality and Derenzo phantom studies. Results showed that PET-SORTEO reliably reproduces the performances of this Inveon preclinical system. In addition, imaging studies showed that the PET-SORTEO simulation program provides raw data for the Inveon scanner that can be fully corrected and reconstructed using the same programs as for the actual data. All correction techniques (attenuation, scatter, randoms, dead-time, and normalization) can be applied on the simulated data leading to fully quantitative reconstructed images. In the second part of the study, we demonstrated its ability to generate fast and realistic biological studies. PET-SORTEO is a workable and reliable tool that can be used, in a classical way, to validate and/or optimize a single PET data processing step such as a reconstruction method. However, we demonstrated that by combining a realistic simulated biological study ([11C]Raclopride here) involving different condition groups, simulation allows one also to assess and optimize the data correction, reconstruction and data processing line flow as a whole, specifically for each biological study, which is our ultimate intent.

  7. Feasibility of Pathology-Correlated Lung Imaging for Accurate Target Definition of Lung Tumors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stroom, Joep; Blaauwgeers, Hans; Baardwijk, Angela van

    2007-09-01

    Purpose: To accurately define the gross tumor volume (GTV) and clinical target volume (GTV plus microscopic disease spread) for radiotherapy, the pretreatment imaging findings should be correlated with the histopathologic findings. In this pilot study, we investigated the feasibility of pathology-correlated imaging for lung tumors, taking into account lung deformations after surgery. Methods and Materials: High-resolution multislice computed tomography (CT) and positron emission tomography (PET) scans were obtained for 5 patients who had non-small-cell lung cancer (NSCLC) before lobectomy. At the pathologic examination, the involved lung lobes were inflated with formalin, sectioned in parallel slices, and photographed, and microscopic sectionsmore » were obtained. The GTVs were delineated for CT and autocontoured at the 42% PET level, and both were compared with the histopathologic volumes. The CT data were subsequently reformatted in the direction of the macroscopic sections, and the corresponding fiducial points in both images were compared. Hence, the lung deformations were determined to correct the distances of microscopic spread. Results: In 4 of 5 patients, the GTV{sub CT} was, on average, 4 cm{sup 3} ({approx}53%) too large. In contrast, for 1 patient (with lymphangitis carcinomatosa), the GTV{sub CT} was 16 cm{sup 3} ({approx}40%) too small. The GTV{sub PET} was too small for the same patient. Regarding deformations, the volume of the well-inflated lung lobes on pathologic examination was still, on average, only 50% of the lobe volume on CT. Consequently, the observed average maximal distance of microscopic spread (5 mm) might, in vivo, be as large as 9 mm. Conclusions: Our results have shown that pathology-correlated lung imaging is feasible and can be used to improve target definition. Ignoring deformations of the lung might result in underestimation of the microscopic spread.« less

  8. Integrated PET/MR breast cancer imaging: Attenuation correction and implementation of a 16-channel RF coil

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Oehmigen, Mark, E-mail: mark.oehmigen@uni-due.de

    Purpose: This study aims to develop, implement, and evaluate a 16-channel radiofrequency (RF) coil for integrated positron emission tomography/magnetic resonance (PET/MR) imaging of breast cancer. The RF coil is designed for optimized MR imaging performance and PET transparency and attenuation correction (AC) is applied for accurate PET quantification. Methods: A 16-channel breast array RF coil was designed for integrated PET/MR hybrid imaging of breast cancer lesions. The RF coil features a lightweight rigid design and is positioned with a spacer at a defined position on the patient table of an integrated PET/MR system. Attenuation correction is performed by generating andmore » applying a dedicated 3D CT-based template attenuation map. Reposition accuracy of the RF coil on the system patient table while using the positioning frame was tested in repeated measurements using MR-visible markers. The MR, PET, and PET/MR imaging performances were systematically evaluated using modular breast phantoms. Attenuation correction of the RF coil was evaluated with difference measurements of the active breast phantoms filled with radiotracer in the PET detector with and without the RF coil in place, serving as a standard of reference measurement. The overall PET/MR imaging performance and PET quantification accuracy of the new 16-channel RF coil and its AC were then evaluated in first clinical examinations on ten patients with local breast cancer. Results: The RF breast array coil provides excellent signal-to-noise ratio and signal homogeneity across the volume of the breast phantoms in MR imaging and visualizes small structures in the phantoms down to 0.4 mm in plane. Difference measurements with PET revealed a global loss and thus attenuation of counts by 13% (mean value across the whole phantom volume) when the RF coil is placed in the PET detector. Local attenuation ranging from 0% in the middle of the phantoms up to 24% was detected in the peripheral regions of the phantoms at positions closer to attenuating hardware structures of the RF coil. The position accuracy of the RF coil on the patient table when using the positioning frame was determined well below 1 mm for all three spatial dimensions. This ensures perfect position match between the RF coil and its three-dimensional attenuation template during the PET data reconstruction process. When applying the CT-based AC of the RF coil, the global attenuation bias was mostly compensated to ±0.5% across the entire breast imaging volume. The patient study revealed high quality MR, PET, and combined PET/MR imaging of breast cancer. Quantitative activity measurements in all 11 breast cancer lesions of the ten patients resulted in increased mean difference values of SUV{sub max} 11.8% (minimum 3.2%; maximum 23.2%) between nonAC images and images when AC of the RF breast coil was applied. This supports the quantitative results of the phantom study as well as successful attenuation correction of the RF coil. Conclusions: A 16-channel breast RF coil was designed for optimized MR imaging performance and PET transparency and was successfully integrated with its dedicated attenuation correction template into a whole-body PET/MR system. Systematic PET/MR imaging evaluation with phantoms and an initial study on patients with breast cancer provided excellent MR and PET image quality and accurate PET quantification.« less

  9. Preparation and dyeing of super hydrophilic polyethylene terephthalate fabric

    NASA Astrophysics Data System (ADS)

    Zheng, D. D.; Zhou, J. F.; Xu, F.; Zhang, F. X.; Zhang, G. X.

    2016-07-01

    In this study, the dyeing properties of PET fabrics modified with sulfuric acid was investigated using disperse red E-4B and disperse blue 2BLNG-L at high temperature and high pressure. The results revealed that the sulfuric acid modification improved the K/S value of dyeing PET fabrics, and the modified PET fabric could be dyed uniformly. The a, b, C, L and H of modified PET fabric were almost the same as that of original PET fabric. The water contact angles were still 0o after 10s, indicating that the hydrophilic property of modified PET fabrics still kept excellent. The wash fastness of dyed PET fabrics after modification was generally good.

  10. Practical Considerations for Clinical PET/MR Imaging.

    PubMed

    Galgano, Samuel; Viets, Zachary; Fowler, Kathryn; Gore, Lael; Thomas, John V; McNamara, Michelle; McConathy, Jonathan

    2018-01-01

    Clinical PET/MR imaging is currently performed at a number of centers around the world as part of routine standard of care. This article focuses on issues and considerations for a clinical PET/MR imaging program, focusing on routine standard-of-care studies. Although local factors influence how clinical PET/MR imaging is implemented, the approaches and considerations described here intend to apply to most clinical programs. PET/MR imaging provides many more options than PET/computed tomography with diagnostic advantages for certain clinical applications but with added complexity. A recurring theme is matching the PET/MR imaging protocol to the clinical application to balance diagnostic accuracy with efficiency. Copyright © 2017 Elsevier Inc. All rights reserved.

  11. Practical Considerations for Clinical PET/MR Imaging.

    PubMed

    Galgano, Samuel; Viets, Zachary; Fowler, Kathryn; Gore, Lael; Thomas, John V; McNamara, Michelle; McConathy, Jonathan

    2017-05-01

    Clinical PET/MR imaging is currently performed at a number of centers around the world as part of routine standard of care. This article focuses on issues and considerations for a clinical PET/MR imaging program, focusing on routine standard-of-care studies. Although local factors influence how clinical PET/MR imaging is implemented, the approaches and considerations described here intend to apply to most clinical programs. PET/MR imaging provides many more options than PET/computed tomography with diagnostic advantages for certain clinical applications but with added complexity. A recurring theme is matching the PET/MR imaging protocol to the clinical application to balance diagnostic accuracy with efficiency. Copyright © 2016 Elsevier Inc. All rights reserved.

  12. Deformation field correction for spatial normalization of PET images

    PubMed Central

    Bilgel, Murat; Carass, Aaron; Resnick, Susan M.; Wong, Dean F.; Prince, Jerry L.

    2015-01-01

    Spatial normalization of positron emission tomography (PET) images is essential for population studies, yet the current state of the art in PET-to-PET registration is limited to the application of conventional deformable registration methods that were developed for structural images. A method is presented for the spatial normalization of PET images that improves their anatomical alignment over the state of the art. The approach works by correcting the deformable registration result using a model that is learned from training data having both PET and structural images. In particular, viewing the structural registration of training data as ground truth, correction factors are learned by using a generalized ridge regression at each voxel given the PET intensities and voxel locations in a population-based PET template. The trained model can then be used to obtain more accurate registration of PET images to the PET template without the use of a structural image. A cross validation evaluation on 79 subjects shows that the proposed method yields more accurate alignment of the PET images compared to deformable PET-to-PET registration as revealed by 1) a visual examination of the deformed images, 2) a smaller error in the deformation fields, and 3) a greater overlap of the deformed anatomical labels with ground truth segmentations. PMID:26142272

  13. The power of support from companion animals for people living with mental health problems: a systematic review and narrative synthesis of the evidence.

    PubMed

    Brooks, Helen Louise; Rushton, Kelly; Lovell, Karina; Bee, Penny; Walker, Lauren; Grant, Laura; Rogers, Anne

    2018-02-05

    There is increasing recognition of the therapeutic function pets can play in relation to mental health. However, there has been no systematic review of the evidence related to the comprehensive role of companion animals and how pets might contribute to the work associated with managing a long-term mental health condition. The aim of this study was to explore the extent, nature and quality of the evidence implicating the role and utility of pet ownership for people living with a mental health condition. A systematic search for studies exploring the role of companion animals in the management of mental health conditions was undertaken by searching 9 databases and undertaking a scoping review of grey literature from the earliest record until March 2017. To be eligible for inclusion, studies had to be published in English and report on primary data related to the relationship between domestic animal ownership and the management of diagnosable mental health conditions. Synthesis of qualitative and quantitative data was undertaken in parallel using a narrative synthesis informed by an illness work theoretical framework. A total of 17 studies were included in the review. Quantitative evidence relating to the benefits of pet ownership was mixed with included studies demonstrating positive, negative and neutral impacts of pet ownership. Qualitative studies illuminated the intensiveness of connectivity people with companion animals reported, and the multi-faceted ways in which pets contributed to the work associated with managing a mental health condition, particularly in times of crisis. The negative aspects of pet ownership were also highlighted, including the practical and emotional burden of pet ownership and the psychological impact that losing a pet has. This review suggests that pets provide benefits to those with mental health conditions. Further research is required to test the nature and extent of this relationship, incorporating outcomes that cover the range of roles and types of support pets confer in relation to mental health and the means by which these can be incorporated into the mainstay of support for people experiencing a mental health problem.

  14. Prospective international cohort study demonstrates inability of interim PET to predict treatment failure in diffuse large B-cell lymphoma.

    PubMed

    Carr, Robert; Fanti, Stefano; Paez, Diana; Cerci, Juliano; Györke, Tamás; Redondo, Francisca; Morris, Tim P; Meneghetti, Claudio; Auewarakul, Chirayu; Nair, Reena; Gorospe, Charity; Chung, June-Key; Kuzu, Isinsu; Celli, Monica; Gujral, Sumeet; Padua, Rose Ann; Dondi, Maurizio

    2014-12-01

    The International Atomic Energy Agency sponsored a large, multinational, prospective study to further define PET for risk stratification of diffuse large B-cell lymphoma and to test the hypothesis that international biological diversity or diversity of healthcare systems may influence the kinetics of treatment response as assessed by interim PET (I-PET). Cancer centers in Brazil, Chile, Hungary, India, Italy, the Philippines, South Korea, and Thailand followed a common protocol based on treatment with R-CHOP (cyclophosphamide, hydroxyadriamycin, vincristine, prednisolone with rituximab), with I-PET after 2-3 cycles of chemotherapy and at the end of chemotherapy scored visually. Two-year survivals for all 327 patients (median follow-up, 35 mo) were 79% (95% confidence interval [CI], 74%-83%) for event-free survival (EFS) and 86% (95% CI, 81%-89%) for overall survival (OS). Two hundred ten patients (64%) were I-PET-negative, and 117 (36%) were I-PET-positive. Two-year EFS was 90% (95% CI, 85%-93%) for I-PET-negative and 58% (95% CI, 48%-66%) for I-PET-positive, with a hazard ratio of 5.31 (95% CI, 3.29-8.56). Two-year OS was 93% (95% CI, 88%-96%) for I-PET-negative and 72% (95% CI, 63%-80%) for I-PET-positive, with a hazard ratio of 3.86 (95% CI, 2.12-7.03). On sequential monitoring, 192 of 312 (62%) patients had complete response at both I-PET and end-of-chemotherapy PET, with an EFS of 97% (95% CI, 92%-98%); 110 of these with favorable clinical indicators had an EFS of 98% (95% CI, 92%-100%). In contrast, the 107 I-PET-positive cases segregated into 2 groups: 58 (54%) achieved PET-negative complete remission at the end of chemotherapy (EFS, 86%; 95% CI, 73%-93%); 46% remained PET-positive (EFS, 35%; 95% CI, 22%-48%). Heterogeneity analysis found no significant difference between countries for outcomes stratified by I-PET. This large international cohort delivers 3 novel findings: treatment response assessed by I-PET is comparable across disparate healthcare systems, secondly a negative I-PET findings together with good clinical status identifies a group with an EFS of 98%, and thirdly a single I-PET scan does not differentiate chemoresistant lymphoma from complete response and cannot be used to guide risk-adapted therapy. © 2014 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  15. Applying Amide Proton Transfer MR Imaging to Hybrid Brain PET/MR: Concordance with Gadolinium Enhancement and Added Value to [18F]FDG PET.

    PubMed

    Sun, Hongzan; Xin, Jun; Zhou, Jinyuan; Lu, Zaiming; Guo, Qiyong

    2018-06-01

    The purpose of this study is to evaluate the diagnostic concordance and metric correlations of amide proton transfer (APT) imaging with gadolinium-enhanced magnetic resonance imaging (MRI) and 2-deoxy-2-[ 18 F-]fluoro-D-glucose ([ 18 F]FDG) positron emission tomography (PET), using hybrid brain PET/MRI. Twenty-one subjects underwent brain gadolinium-enhanced [ 18 F]FDG PET/MRI prospectively. Imaging accuracy was compared between unenhanced MRI, MRI with enhancement, APT-weighted (APTW) images, and PET based on six diagnostic criteria. Among tumors, the McNemar test was further used for concordance assessment between gadolinium-enhanced imaging, APT imaging, and [ 18 F]FDG PET. As well, the relation of metrics between APT imaging and PET was analyzed by the Pearson correlation analysis. APT imaging and gadolinium-enhanced MRI showed superior and similar diagnostic accuracy. APTW signal intensity and gadolinium enhancement were concordant in 19 tumors (100 %), while high [ 18 F]FDG avidity was shown in only 12 (63.2 %). For the metrics from APT imaging and PET, there was significant correlation for 13 hypermetabolic tumors (P < 0.05) and no correlation for the remaining six [ 18 F]FDG-avid tumors. APT imaging can be used to increase diagnostic accuracy with no need to administer gadolinium chelates. APT imaging may provide an added value to [ 18 F]FDG PET in the evaluation of tumor metabolic activity during brain PET/MR studies.

  16. Association between pet ownership and coronary artery disease in a Chinese population.

    PubMed

    Xie, Zhi-Yong; Zhao, Di; Chen, Bing-Rui; Wang, You-Nan; Ma, Yao; Shi, Hao-Jie; Yang, Yang; Wang, Ze-Mu; Wang, Lian-Sheng

    2017-03-01

    A number of studies have suggested the benefits of pet ownership to human health, including cardiovascular disease (CVD). However, there are few findings regarding pet ownership and coronary artery disease (CAD). The objective of this study is to investigate the association between pet ownership and CAD in a Chinese population. From October 2015 to May 2016, a survey consisting of 561 consecutive patients was done in Nanjing, China. Based on the results of coronary arteriography for the first time, participants were divided into 2 groups (non-CAD and CAD groups). Pet ownership information was collected by using a questionnaire. After multivariate adjustments, pet ownership was associated with a decreased CAD risk (odds ratios [OR]: 0.504, 95% confidence intervals [CIs]: 0.310-0.819). There was a reduced CAD risk among dog owners (OR: 0.420, 95% CI: 0.242-0.728) when compared with the cat group (OR: 0.738, 95% CI: 0.240-2.266) and the cat and dog group (OR: 1.052, 95% CI: 0.330-3.355). With the increase of pet ownership duration, there was a decreased tendency of CAD risk, including years of keeping pets (P for trend = 0.008) and time of playing with pets per day (P for trend = 0.001). In addition, similar dose-response relationship was observed for starting age of keeping pets (P for trend = 0.002). Pet ownership, especially dog ownership, can be a protective factor for CAD in Chinese patients.

  17. Behavioral Intervention for Domestic Pet Mistreatment in a Young Child with Autism

    ERIC Educational Resources Information Center

    Bergstrom, Ryan; Tarbox, Jonathan; Gutshall, Katharine A.

    2011-01-01

    Household pets can have a positive influence on quality of life for individuals who live with them (Bryant, 1990). Little previous research has investigated issues related to interaction between individuals with developmental disabilities and pets. In this study, we used simple behavioral intervention procedures to decrease pet mistreatment by a…

  18. Pet Care Teaching Unit: 1st-3rd Grades.

    ERIC Educational Resources Information Center

    Peninsula Humane Society, San Mateo, CA.

    Activities in this unit are designed to familiarize primary grade students with the responsibilities involved in pet ownership. Teaching plans are provided for a total of 12 lessons involving social studies, language arts, math, and health sciences. Activities adaptable for readers and non-readers focus on pet overpopulation, care of pets when…

  19. Complicated grief and posttraumatic stress disorder in humans' response to the death of pets/animals.

    PubMed

    Adrian, Julie A Luiz; Deliramich, Aimee N; Frueh, B Christopher

    2009-01-01

    The present exploratory project represents a cross-sectional study designed to determine the percentage of people reporting significant symptoms of complicated grief (CG) and/or posttraumatic stress disorder (PTSD) in response to the death of companion pets/animals. Human participants (N = 106) were sampled from a veterinary clinic. Fifty-two percent of participants had lost one to three pets from natural causes, 60% had never lost a pet to euthanasia, and 37% had lost one to three pets to euthanasia. The study suggests that many people experience significant attachment to their pets/animals and experience significant features of grief reactions (about 20%) after the death of a pet/animal. However, the percentage of people experiencing major pathological disruption is relatively low (<5%-12%). Thus, subclinical levels of grief and sadness are relatively common human responses to the death of companion pets/animals and last 6 months or more for about 30% of those sampled. Severe pathological reactions do occur but are quite rare among human survivors. Implications for mental health clinicians working with affected populations are discussed.

  20. Enhanced Application of 18F-FDG PET/CT in Bladder Cancer by Adding Early Dynamic Acquisition to a Standard Delayed PET Protocol.

    PubMed

    Yoon, Hai-Jeon; Yoo, Jang; Kim, Yemi; Lee, Dong Hyeon; Kim, Bom Sahn

    2017-10-01

    We investigated the value of early dynamic (ED) PET for the detection and characterization of bladder cancer. Fifty-two bladder cancer patients were prospectively enrolled. The study protocol was composed of ED, whole-body (WB, 60 minutes after injection), and additional delayed (AD, 120 minutes after injection) PET acquisition. Early dynamic PET was acquired for 10 minutes and reconstructed as 5 frames at 2-minute intervals. A focal radiotracer accumulation confined to the bladder wall was considered as PET positive and referred for further quantitative measurement. SUVmax on ED (SUVmax, SUVmax, SUVmax, SUVmax, and SUVmax for 5 frames), WB (SUVmax), and AD PET (SUVmax) were measured. PET results were correlated with bladder cancer pathology variables. The sensitivities of ED, WB, and AD PET for bladder cancer were 84.6%, 57.7%, and 61.2%, respectively. The sensitivity of ED PET was significantly higher than that of WB (P = 0.002) and AD PET (P = 0.008). On ED PET, SUVmax was significantly correlated with muscle invasiveness, histological grade, and pathological tumor size (P = 0.018, P = 0.030, and P = 0.030). On WB and AD PET, only pathological tumor size showed significant positive correlation with SUVmax and SUVmax (P = 0.043 and P = 0.007). Early dynamic PET can help to detect and characterize bladder cancer.

  1. Evacuating People and Their Pets: Older Floridians' Need for and Proximity to Pet-Friendly Shelters.

    PubMed

    Douglas, Rachel; Kocatepe, Ayberk; Barrett, Anne E; Ozguven, Eren Erman; Gumber, Clayton

    2017-10-04

    Pets influence evacuation decisions, but little is known about pet-friendly emergency shelters' availability or older adults' need for them. Our study addresses this issue, focusing on the most densely populated area of Florida (Miami-Dade)-the state with the oldest population and greatest hurricane susceptibility. We use Geographic Information Systems (GIS)-based methodology to identify the shortest paths to pet-friendly shelters, based on distance and congested and uncongested travel times-taking into account the older population's spatial distribution. Logistic regression models using the 2013 American Housing Survey's Disaster Planning Module examine anticipated shelter use as a function of pet ownership and requiring pet evacuation assistance. Thirty-four percent of older adults in the Miami-Dade area have pets-35% of whom report needing pet evacuation assistance. However, GIS accessibility measures show that travel time factors are likely to impede older adults' use of the area's few pet-friendly shelters. Logistic regression results reveal that pet owners are less likely to report anticipating shelter use; however, the opposite holds for pet owners reporting they would need help evacuating their pets-they anticipate using shelters. High pet shelter need coupled with low availability exacerbates older adults' heightened vulnerability during Florida's hurricane season. © The Author 2017. Published by Oxford University Press on behalf of The Gerontological Society of America. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  2. Evaluative studies in nuclear medicine research: positron computed tomography assessment. Final report, January 1, 1982-December 31, 1982

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Potchen, E.J.; Harris, G.I.; Gift, D.A. Reinhard, D.K.

    Results are reported of the final phase of the study effort generally titled Evaluative Studies in Nuclear Medicine Research. The previous work is reviewed and extended to an assessment providing perspectives on medical applications of positron emission tomographic (PET) systems, their technological context, and the related economic and marketing environment. Methodologies developed and used in earlier phases of the study were continued, but specifically extended to include solicitation of opinion from commercial organizations deemed to be potential developers, manufacturers and marketers of PET systems. Several factors which influence the demand for clinical uses of PET are evaluated and discussed. Themore » recent Federal funding of applied research with PET systems is found to be a necessary and encouraging event toward a determination that PET either is a powerful research tool limited to research, or whether it also presents major clinical utility. A comprehensive, updated bibliography of current literature related to the development, applications and economic considerations of PET technology is appended.« less

  3. Development of PET/MRI with insertable PET for simultaneous PET and MR imaging of human brain

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jung, Jin Ho; Choi, Yong, E-mail: ychoi.image@gmail.com; Jung, Jiwoong

    2015-05-15

    Purpose: The purpose of this study was to develop a dual-modality positron emission tomography (PET)/magnetic resonance imaging (MRI) with insertable PET for simultaneous PET and MR imaging of the human brain. Methods: The PET detector block was composed of a 4 × 4 matrix of detector modules, each consisting of a 4 × 4 array LYSO coupled to a 4 × 4 Geiger-mode avalanche photodiode (GAPD) array. The PET insert consisted of 18 detector blocks, circularly mounted on a custom-made plastic base to form a ring with an inner diameter of 390 mm and axial length of 60 mm. Themore » PET gantry was shielded with gold-plated conductive fabric tapes with a thickness of 0.1 mm. The charge signals of PET detector transferred via 4 m long flat cables were fed into the position decoder circuit. The flat cables were shielded with a mesh-type aluminum sheet with a thickness of 0.24 mm. The position decoder circuit and field programmable gate array-embedded DAQ modules were enclosed in an aluminum box with a thickness of 10 mm and located at the rear of the MR bore inside the MRI room. A 3-T human MRI system with a Larmor frequency of 123.7 MHz and inner bore diameter of 60 cm was used as the PET/MRI hybrid system. A custom-made radio frequency (RF) coil with an inner diameter of 25 cm was fabricated. The PET was positioned between gradient and the RF coils. PET performance was measured outside and inside the MRI scanner using echo planar imaging, spin echo, turbo spin echo, and gradient echo sequences. MRI performance was also evaluated with and without the PET insert. The stability of the newly developed PET insert was evaluated and simultaneous PET and MR images of a brain phantom were acquired. Results: No significant degradation of the PET performance caused by MR was observed when the PET was operated using various MR imaging sequences. The signal-to-noise ratio of MR images was slightly degraded due to the PET insert installed inside the MR bore while the homogeneity was maintained. The change of gain of the 256 GAPD/scintillator elements of a detector block was <3% for 60 min, and simultaneous PET and MR images of a brain phantom were successfully acquired. Conclusions: Experimental results indicate that a compact and lightweight PET insert for hybrid PET/MRI can be developed using GAPD arrays and charge signal transmission method proposed in this study without significant interference.« less

  4. Gamma-camera 18F-FDG PET in diagnosis and staging of patients presenting with suspected lung cancer and comparison with dedicated PET.

    PubMed

    Oturai, Peter S; Mortensen, Jann; Enevoldsen, Henriette; Eigtved, Annika; Backer, Vibeke; Olesen, Knud P; Nielsen, Henrik W; Hansen, Hanne; Stentoft, Poul; Friberg, Lars

    2004-08-01

    It is not clear whether high-quality coincidence gamma-PET (gPET) cameras can provide clinical data comparable with data obtained with dedicated PET (dPET) cameras in the primary diagnostic work-up of patients with suspected lung cancer. This study focuses on 2 main issues: direct comparison between foci resolved with the 2 different PET scanners and the diagnostic accuracy compared with final diagnosis determined by the combined information from all other investigations and clinical follow-up. Eighty-six patients were recruited to this study through a routine diagnostic program. They all had changes on their chest radiographs, suggesting malignant lung tumor. In addition to the standard diagnostic program, each patient had 2 PET scans that were performed on the same day. After administration of 419 MBq (range = 305-547 MBq) (18)F-FDG, patients were scanned in a dedicated PET scanner about 1 h after FDG administration and in a dual-head coincidence gamma-camera about 3 h after tracer injection. Images from the 2 scans were evaluated in a blinded set-up and compared with the final outcome. Malignant intrathoracic disease was found in 52 patients, and 47 patients had primary lung cancers. dPET detected all patients as having malignancies (sensitivity, 100%; specificity, 50%), whereas gPET missed one patient (sensitivity, 98%; specificity, 56%). For evaluating regional lymph node involvement, sensitivity and specificity rates were 78% and 84% for dPET and 61% and 90% for gPET, respectively. When comparing the 2 PET techniques with clinical tumor stage (TNM), full agreement was obtained in 64% of the patients (Cohen's kappa = 0.56). Comparing categorization of the patients into clinical relevant stages (no malignancy/malignancy suitable for treatment with curative intent/nontreatable malignancy), resulted in full agreement in 81% (Cohen's kappa = 0.71) of patients. Comparing results from a recent generation of gPET cameras obtained about 2 h later than those of dPET, there was a fairly good agreement with regard to detecting primary lung tumors but slightly reduced sensitivity in detecting smaller malignant lesions such as lymph nodes. Depending on the population to be investigated, and if dPET is not available, gPET might provide significant diagnostic information in patients in whom lung cancer is suspected.

  5. Integrated whole-body PET/MR imaging with 18F-FDG, 18F-FDOPA, and 18F-fluorodopamine in paragangliomas, in comparison to PET/CT: NIH first clinical experience with a single-injection, dual-modality imaging protocol

    PubMed Central

    Blanchet, Elise M.; Millo, Corina; Martucci, Victoria; Maass-Moreno, Roberto; Bluemke, David A.; Pacak, Karel

    2017-01-01

    Purpose Paragangliomas (PGLs) are tumors that can metastasize and recur; therefore, lifelong imaging follow-up is required. Hybrid positron emission tomography (PET)/computed tomography (/CT) is an essential tool to image PGLs. Novel hybrid PET/magnetic resonance (/MR) scanners are currently being studied in clinical oncology. We studied the feasibility of simultaneous whole-body PET/MR imaging to evaluate patients with PGLs. Methods Fifty-three PGLs or PGL-related lesions from eight patients were evaluated. All patients underwent a single-injection, dual-modality imaging protocol consisting of a PET/CT and subsequent PET/MR scan. Four patients were evaluated with 18F-fluorodeoxyglucose (18F-FDG), two with 18F-fluorodihydroxyphenylalanine (18F-FDOPA), and two with 18F-fluorodopamine (18F-FDA). PET/MR data were acquired using a hybrid whole-body 3-Tesla integrated PET/MR scanner. PET and MR data (DIXON images for attenuation correction and T2-weighted sequences for anatomic allocation) were acquired simultaneously. Imaging workflow and imaging times were documented. PET/MR and PET/CT data were visually assessed (blindly) in regards to image quality, lesion detection, and anatomic allocation and delineation of the PET findings. Results With hybrid PET/MR, we obtained high quality images in an acceptable acquisition time (median: 31 min, range: 25–40 min) with good patient compliance. A total of 53 lesions, located in the head-and-neck area (6), mediastinum (2), abdomen and pelvis (13), lungs (2), liver (4), and bone (26) were evaluated. 51 lesions were detected with PET/MR and confirmed by PET/CT. Two bone lesions (L4 body (8 mm) and sacrum (6 mm)) were not detectable on an 18F-FDA scan PET/MR, likely due to washout of the 18F-FDA. Co-registered MR tended to be superior to co-registered CT for head-and-neck, abdomen, pelvis, and liver lesions for anatomic allocation and delineation. Conclusions Clinical PGL evaluation with hybrid PET/MR is feasible with high image-quality and can be obtained in a reasonable time. It could be particularly beneficial for the pediatric population and for precise lesion definition in the head-and-neck, abdomen, pelvis, and liver. PMID:24152658

  6. Reproducibility of MR-Based Attenuation Maps in PET/MRI and the Impact on PET Quantification in Lung Cancer.

    PubMed

    Olin, Anders; Ladefoged, Claes N; Langer, Natasha H; Keller, Sune H; Löfgren, Johan; Hansen, Adam E; Kjær, Andreas; Langer, Seppo W; Fischer, Barbara M; Andersen, Flemming L

    2018-06-01

    Quantitative PET/MRI is dependent on reliable and reproducible MR-based attenuation correction (MR-AC). In this study, we evaluated the quality of current vendor-provided thoracic MR-AC maps and further investigated the reproducibility of their impact on 18 F-FDG PET quantification in patients with non-small cell lung cancer. Methods: Eleven patients with inoperable non-small cell lung cancer underwent 2-5 thoracic PET/MRI scan-rescan examinations within 22 d. 18 F-FDG PET data were acquired along with 2 Dixon MR-AC maps for each examination. Two PET images (PET A and PET B ) were reconstructed using identical PET emission data but with MR-AC from these intrasubject repeated attenuation maps. In total, 90 MR-AC maps were evaluated visually for quality and the occurrence of categorized artifacts by 2 PET/MRI-experienced physicians. Each tumor was outlined by a volume of interest (40% isocontour of maximum) on PET A , which was then projected onto the corresponding PET B SUV mean and SUV max were assessed from the PET images. Within-examination coefficients of variation and Bland-Altman analyses were conducted for the assessment of SUV variations between PET A and PET B Results: Image artifacts were observed in 86% of the MR-AC maps, and 30% of the MR-AC maps were subjectively expected to affect the tumor SUV. SUV mean and SUV max resulted in coefficients of variation of 5.6% and 6.6%, respectively, and scan-rescan SUV variations were within ±20% in 95% of the cases. Substantial SUV variations were seen mainly for scan-rescan examinations affected by respiratory motion. Conclusion: Artifacts occur frequently in standard thoracic MR-AC maps, affecting the reproducibility of PET/MRI. These, in combination with other well-known sources of error associated with PET/MRI examinations, lead to inconsistent SUV measurements in serial studies, which may affect the reliability of therapy response assessment. A thorough visual inspection of the thoracic MR-AC map and Dixon images from which it is derived remains crucial for the detection of MR-AC artifacts that may influence the reliability of SUV. © 2018 by the Society of Nuclear Medicine and Molecular Imaging.

  7. Characterization and quality assessment of recycled post-consumption poly(ethylene terephthalate) (PET).

    PubMed

    Masmoudi, Fatma; Fenouillot, Françoise; Mehri, Afef; Jaziri, Mohamed; Ammar, Emna

    2018-06-05

    In the present study, the recycled post-consumption polyethylene terephthalate (PET) flakes were investigated as possible raw materials for the production of food packaging. After heating at 220 °C for 1 h, a steaming stage was conducted as a control test to assess the quality of the product. Different samples were characterized by 1 H-NMR, FT-IR, DSC/TGA analysis, viscosity index (VI), and trace metals analysis. The results showed that the recycled post-consumed PET flakes' properties were generally conform to the standard norms of PET except the color of some flakes turned to yellow. Subsequently, a complementary study was undertaken to assess whether the material could be possibly reused for food packaging. For this purpose, rheological, thermal, and mechanical characterizations were performed. The results of the comparative study between the virgin and the recycled PET flakes concluded that the PET recycling affected the rheological properties but did not have any significant effect on their thermal and mechanical characteristics. Hence, it was deduced that the post-consumed PET flakes could be reused as a packaging material except food products.

  8. Final Report 2007: DOE-FG02-87ER60561

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kilbourn, Michael R

    2007-04-26

    This project involved a multi-faceted approach to the improvement of techniques used in Positron Emission Tomography (PET), from radiochemistry to image processing and data analysis. New methods for radiochemical syntheses were examined, new radiochemicals prepared for evaluation and eventual use in human PET studies, and new pre-clinical methods examined for validation of biochemical parameters in animal studies. The value of small animal PET imaging in measuring small changes of in vivo biochemistry was examined and directly compared to traditional tissue sampling techniques. In human imaging studies, the ability to perform single experimental sessions utilizing two overlapping injections of radiopharmaceuticals wasmore » tested, and it was shown that valid biochemical measures for both radiotracers can be obtained through careful pharmacokinetic modeling of the PET emission data. Finally, improvements in reconstruction algorithms for PET data from small animal PET scanners was realized and these have been implemented in commercial releases. Together, the project represented an integrated effort to improve and extend all basic science aspects of PET imaging at both the animal and human level.« less

  9. Human-pet interaction and loneliness: a test of concepts from Roy's adaptation model.

    PubMed

    Calvert, M M

    1989-01-01

    This research used two key concepts from Roy's adaptation model of nursing to examine the relationship between human-pet interaction and loneliness in nursing home residents. These concepts included (a) environmental stimuli as factors influencing adaptation and (b) interdependence as a mode of response to the environment. The hypothesis of this study asserted that the residents of a nursing home who had greater levels of interaction with a pet program would experience less loneliness than those who had lower levels of interaction with a pet. The study used an ex post facto nonexperimental design with 65 subjects. The simplified version of the revised UCLA loneliness scale was used to measure loneliness. Reported level of human-pet interaction was measured according to a four-point scale (1 = no interaction, 4 = quite a lot of interaction). The hypothesis was supported at the p less than 0.03 level of significance. Implications for practice through organizing pet programs in situations where loneliness exists are discussed. Recommendations for future research include replicating the study using a larger sample and developing a comprehensive human-pet interaction tool.

  10. Infectious microorganisms in mice (Mus musculus) purchased from commercial pet shops in Germany.

    PubMed

    Dammann, P; Hilken, G; Hueber, B; Köhl, W; Bappert, M T; Mähler, M

    2011-10-01

    In this study, we investigated the prevalence of infectious microorganisms (viruses, bacteria, fungi and eukaryotic parasites) in mice from different pet shops in Germany; such animals may compromise the hygienic integrity of laboratory animal vivaria if private pet holders act as unintended vectors of infections carried by them. House mice sold as pets or feed specimens were purchased from different pet shops and tested for a comprehensive panel of unwanted microorganisms. We found a number of microorganisms in these pet shop mice, the most prevalent of which were Helicobacter species (92.9%), mouse parvovirus (89.3%), mouse hepatitis virus (82.7%), Pasteurella pneumotropica (71.4%) and Syphacia species (57.1%). Several microorganisms (e.g. mouse parvovirus, Theiler's murine encephalomyelitis virus, pneumonia virus of mice, Encephalitozoon cuniculi, Clostridium piliforme) had considerably higher prevalences than those reported in similar studies on wild mice from North America, Europe or Australia. Our study shows that direct contact with pet shop mice may constitute a risk for laboratory animal vivaria if hygienic precautions are not taken. However, even relatively simple precautions seem effective enough to hold the risk at bay.

  11. Methodological aspects of multicenter studies with quantitative PET.

    PubMed

    Boellaard, Ronald

    2011-01-01

    Quantification of whole-body FDG PET studies is affected by many physiological and physical factors. Much of the variability in reported standardized uptake value (SUV) data seen in the literature results from the variability in methodology applied among these studies, i.e., due to the use of different scanners, acquisition and reconstruction settings, region of interest strategies, SUV normalization, and/or corrections methods. To date, the variability in applied methodology prohibits a proper comparison and exchange of quantitative FDG PET data. Consequently, the promising role of quantitative PET has been demonstrated in several monocentric studies, but these published results cannot be used directly as a guideline for clinical (multicenter) trials performed elsewhere. In this chapter, the main causes affecting whole-body FDG PET quantification and strategies to minimize its inter-institute variability are addressed.

  12. Assessing the role of 18F-FDG PET and 18F-FDG PET/CT in the diagnosis of soft tissue musculoskeletal malignancies – A systematic review and meta-analysis

    PubMed Central

    Etchebehere, Elba C.; Hobbs, Brian P.; R.Milton, Denái; Malawi, Osama; Patel, Shreyaskumar; Benjamin, Robert S.; Macapinlac, Homer A.

    2016-01-01

    Purpose Twelve years ago a meta-analysis evaluated the diagnostic performance of 18F-FDG PET in assessing musculoskeletal soft tissue lesions (MsSTL). Currently, PET/CT has substituted PET imaging however there has not been any published meta-analysis on the use of PET/CT or a comparison of PET/CT with PET in the diagnosis of MsSTL. Therefore, we conducted a meta-analysis to identify the current diagnostic performance of 18F-FDG PET/CT and determine if there is added value when compared to PET. Patients and Methods A systematic review of English articles using MEDLINE PubMed, the Cochrane Library and EMBASE were searched from 1996 to March 2015. Studies exploring the diagnostic accuracy of 18F-FDG PET/CT (or dedicated PET) compared to histopathology in patients with MsSTL undergoing investigation for malignancy were included. Results Our meta-analysis included 14 articles composed of 755 patients with 757 soft tissue lesions. There were 451 (60%) malignant tumors and 306 benign lesions. The 18F-FDG PET/CT (and dedicated PET) mean sensitivity, specificity, accuracy, positive and negative predictive values for diagnosing MsSTL was 0.96 (0.90, 1.00), 0.77 (0.67, 0.86), 0.88 (0.85, 0.91), 0.86 (0.78, 0.94) and 0.91 (0.83, 0.99), respectively. The posterior mean (95% HPD interval) for the AUC was 0.92 (0.88, 0.96). PET/CT had higher specificity, accuracy and positive predictive value when compared to a dedicated PET (0.85, 0.89 and 0.91 vs 0.71, 0.85 and 0.82, respectively). Conclusions 18F-FDG PET/CT and dedicated PET are both highly accurate in the diagnosis of MsSTL. PET/CT is more accurate, specific and has a higher positive predictive value than PET. PMID:26631240

  13. Quality control for quantitative multicenter whole-body PET/MR studies: A NEMA image quality phantom study with three current PET/MR systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Boellaard, Ronald, E-mail: r.boellaard@vumc.nl; European Association of Nuclear Medicine Research Ltd., Vienna 1060; European Association of Nuclear Medicine Physics Committee, Vienna 1060

    2015-10-15

    Purpose: Integrated positron emission tomography/magnetic resonance (PET/MR) systems derive the PET attenuation correction (AC) from dedicated MR sequences. While MR-AC performs reasonably well in clinical patient imaging, it may fail for phantom-based quality control (QC). The authors assess the applicability of different protocols for PET QC in multicenter PET/MR imaging. Methods: The National Electrical Manufacturers Association NU 2 2007 image quality phantom was imaged on three combined PET/MR systems: a Philips Ingenuity TF PET/MR, a Siemens Biograph mMR, and a GE SIGNA PET/MR (prototype) system. The phantom was filled according to the EANM FDG-PET/CT guideline 1.0 and scanned for 5more » min over 1 bed. Two MR-AC imaging protocols were tested: standard clinical procedures and a dedicated protocol for phantom tests. Depending on the system, the dedicated phantom protocol employs a two-class (water and air) segmentation of the MR data or a CT-based template. Differences in attenuation- and SUV recovery coefficients (RC) are reported. PET/CT-based simulations were performed to simulate the various artifacts seen in the AC maps (μ-map) and their impact on the accuracy of phantom-based QC. Results: Clinical MR-AC protocols caused substantial errors and artifacts in the AC maps, resulting in underestimations of the reconstructed PET activity of up to 27%, depending on the PET/MR system. Using dedicated phantom MR-AC protocols, PET bias was reduced to −8%. Mean and max SUV RC met EARL multicenter PET performance specifications for most contrast objects, but only when using the dedicated phantom protocol. Simulations confirmed the bias in experimental data to be caused by incorrect AC maps resulting from the use of clinical MR-AC protocols. Conclusions: Phantom-based quality control of PET/MR systems in a multicenter, multivendor setting may be performed with sufficient accuracy, but only when dedicated phantom acquisition and processing protocols are used for attenuation correction.« less

  14. A Prospective Study of {sup 18}FDG-PET With CT Coregistration for Radiation Treatment Planning of Lymphomas and Other Hematologic Malignancies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Terezakis, Stephanie A.; Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins School of Medicine, Baltimore, Maryland; Schöder, Heiko

    2014-06-01

    Purpose: This prospective single-institution study examined the impact of positron emission tomography (PET) with the use of 2-[{sup 18}F] fluoro-2-deoxyglucose and computed tomography (CT) scan radiation treatment planning (TP) on target volume definition in lymphoma. Methods and Materials: 118 patients underwent PET/CT TP during June 2007 to May 2009. Gross tumor volume (GTV) was contoured on CT-only and PET/CT studies by radiation oncologists (ROs) and nuclear medicine physicians (NMPs) for 95 patients with positive PET scans. Treatment plans and dose-volume histograms were generated for CT-only and PET/CT for 95 evaluable sites. Paired t test statistics and Pearson correlation coefficients weremore » used for analysis. Results: 70 (74%) patients had non-Hodgkin lymphoma, 10 (11%) had Hodgkin lymphoma, 12 (10%) had plasma-cell neoplasm, and 3 (3%) had other hematologic malignancies. Forty-three (45%) presented with relapsed/refractory disease. Forty-five (47%) received no prior chemotherapy. The addition of PET increased GTV as defined by ROs in 38 patients (median, 27%; range, 5%-70%) and decreased GTV in 41 (median, 39.5%; range, 5%-80%). The addition of PET increased GTV as defined by NMPs in 27 patients (median, 26.5%; range, 5%-95%) and decreased GTV in 52 (median, 70%; range, 5%-99%). The intraobserver correlation between CT-GTV and PET-GTV was higher for ROs than for NMPs (0.94, P<.01 vs 0.89, P<.01). On the basis of Bland-Altman plots, the PET-GTVs defined by ROs were larger than those defined by NMPs. On evaluation of clinical TPs, only 4 (4%) patients had inadequate target coverage (D95 <95%) of the PET-GTV defined by NMPs. Conclusions: Significant differences between the RO and NMP volumes were identified when PET was coregistered to CT for radiation planning. Despite this, the PET-GTV defined by ROs and NMPs received acceptable prescription dose in nearly all patients. However, given the potential for a marginal miss, consultation with an experienced PET reader is highly encouraged when PET/CT volumes are delineated, particularly for questionable lesions and to assure complete and accurate target volume coverage.« less

  15. Synthesis and characterization of transition metal clusters: From the isolation of ligand-stabilized solid fragments to the tuning of magnetic anisotropy and host-guest selectivity, and, Approaches to science teaching: Development of an observation instrument with a measurement model based on item response theory

    NASA Astrophysics Data System (ADS)

    Hee, Allan George

    Part I. The work presented herein describes efforts to develop general techniques for the synthesis of transition metal clusters and the manipulation of their properties. In Chapter 2, it is demonstrated that a modified metal atom reactor allows for the vaporization, passivation, and isolation of metal-chalcogenide clusters from their parent binary solids. Among the clusters produced by this method were Cr6S8(PEt3)6, Fe4S 4(PEt3)4, Co6S8(PEt 3)6, Cu6S4(PEt3)6, Cu12S6(PEt3)8, and Cu26Se 13(PEt3)14. To create single-molecule magnets with higher demagnetization barriers, we are developing metal-cyanide systems which exhibit highly adjustable magnetic behavior. Chapter 3 reports an attempt to introduce magnetic anisotropy into a MnCr6 cluster. Replacement of CrIII with Mo III resulted in the assembly of K[(Me3tacn)6MnMo 6(CN)18](ClO4)3 (Me3tacn = N,N',N″ -trimethyl-1,4,7-triazacyclononane)---the first well-documented example of a cyano-bridged single-molecule magnet. Recently, it was demonstrated that replacing Me3tacn with the less sterically hindering tach (tach = cis,cis-1,3,5-triaminocyclohexane) in the face-centered cubic cluster [(tach)8Cr8Ni 6(CN)24]Br12 provides greater access to the cluster cavity. Chapter 4 describes my efforts to probe the selectivity of this cluster toward inclusion of various guests. Part II. Successful implementation of student-centered curricula reforms requires the creation of a measurement instrument for monitoring whether the curricula are being used as intended. The creation and development of an observation instrument would greatly contribute to this effort. To develop a theoretically sound construct map, it is necessary to review the literature and conduct our own investigations of approaches to science teaching. Chapter 2 presents the findings of these investigations and their contributions to our understanding of the construct. Using these findings, the Science Teaching Observation Protocol (STOP) was created and designed to measure two subconstructs: intentions and strategies. Chapter 3 details the first pilot test of STOP and analysis of the collected data. In Chapter 4, the theoretical shortcomings of the instrument are analyzed and discussed. Modified versions of the intention and strategy subconstruct maps are presented.

  16. 18F-Fluorodeoxyglucose PET/CT and dynamic contrast-enhanced MRI as imaging biomarkers in malignant pleural mesothelioma.

    PubMed

    Hall, David O; Hooper, Clare E; Searle, Julie; Darby, Michael; White, Paul; Harvey, John E; Braybrooke, Jeremy P; Maskell, Nick A; Masani, Vidan; Lyburn, Iain D

    2018-02-01

    The purpose of this study was to compare the use of fluorine-18-fluorodeoxyglucose (F-FDG) PET with computed tomography (CT) and dynamic contrast-enhanced (DCE) MRI to predict prognosis and monitor treatment in malignant pleural mesothelioma. F-FDG PET/CT and DCE-MRI studies carried out as part of the South West Area Mesothelioma Pemetrexed trial were used. F-FDG PET/CT and DCE-MRI studies were carried out before treatment, and after two cycles of chemotherapy, on patients treated with pemetrexed and cisplatin. A total of 73 patients were recruited, of whom 65 had PET/CT and DCE-MRI scans. Baseline measurements from F-FDG PET/CT (maximum standardized uptake value, metabolic tumour volume and total lesion glycolysis) and DCE-MRI (integrated area under the first 90s of the curve and washout slope) were compared with overall survival (OS) using Kaplan-Meier and Cox regression analyses, and changes in imaging measurements were compared with disease progression. PET/CT and DCE-MRI measurements were not correlated with each other. Maximum standardized uptake value, metabolic tumour volume and total lesion glycolysis were significantly related to OS with Cox regression analysis and Kaplan-Meir analysis, and DCE-MRI washout curve shape was significantly related to OS. DCE-MRI curve shape can be combined with F-FDG PET/CT to give additional prognostic information. Changes in measurements were not related to progression-free survival. F-FDG PET/CT and DCE-MRI give prognostic information in malignant pleural mesothelioma. Neither PET/CT nor DCE-MRI is useful for monitoring disease progression.

  17. Endoscopic ultrasonography in esophageal cancer leads to improved survival rates: results from a population-based study.

    PubMed

    Wani, Sachin; Das, Ananya; Rastogi, Amit; Drahos, Jennifer; Ricker, Winifred; Parsons, Ruth; Bansal, Ajay; Yen, Roy; Hosford, Lindsay; Jankowski, Meghan; Sharma, Prateek; Cook, Michael B

    2015-01-15

    The advantages of endoscopic ultrasound (EUS) and computed tomography (CT)-positron emission tomography (PET) with respect to survival for esophageal cancer patients are unclear. This study aimed to assess the effects of EUS, CT-PET, and their combination on overall survival with respect to cases not receiving these procedures. Patients who were ≥66 years old when diagnosed with esophageal cancer were identified in the Surveillance, Epidemiology, and End Results-Medicare linked database. Cases were split into 4 analytic groups: EUS only (n = 318), CT-PET only (n = 853), EUS+CT-PET (n = 189), and no EUS or CT-PET (n = 2439). Survival times were estimated with the Kaplan-Meier method and were compared with the log-rank test for each group versus the no EUS or CT-PET group. Multivariate Cox proportional hazards models were used to compare 1-, 3-, and 5-year survival rates. Kaplan-Meier analyses showed that EUS, CT-PET, and EUS+CT-PET patients had improved survival for all stages (with the exception of stage 0 disease) in comparison with patients undergoing no EUS or CT-PET. Receipt of EUS increased the likelihood of receiving endoscopic therapies, esophagectomy, and chemoradiation. Multivariate Cox proportional hazards models showed that receipt of EUS was a significant predictor of improved 1- (hazard ratio [HR], 0.49; 95% confidence interval [CI], 0.39-0.59; P < .0001), 3- (HR, 0.57; 95% CI, 0.48-0.66; P < .0001), and 5-year survival (HR, 0.59; 95% CI, 0.50-0.68). Similar results were noted when the results were stratified on the basis of histology and for the CT-PET and EUS+CT-PET groups. Receipt of either EUS or CT-PET alone in esophageal cancer patients was associated with improved 1-, 3-, and 5-year survival. Future studies should identify barriers to the dissemination of these staging modalities. © 2014 American Cancer Society.

  18. The consumption and recycling collection system of PET bottles: a case study of Beijing, China.

    PubMed

    Zhang, Hua; Wen, Zong-Guo

    2014-06-01

    After studying the recycling collection system of polyethylene terephthalate (PET) bottles worldwide, the authors conducted an intercept survey in Beijing. Two separate questionnaires were issued, one questionnaire to PET bottle consumers and one to PET bottle recyclers. In this study, consumers are defined as people that consume PET-bottled beverages in their daily life. Recyclers were defined as those involved in the collection and recycling of PET bottles. These include scavengers, itinerant waste buyers, small community waste-buying depots, medium/large redemption depots, and recycling companies. In total, 580 surveys were completed, including 461 by consumers and 119 by recyclers. The authors found that consumption of PET bottles in Beijing was nearly 100,000 tonnes in 2012. Age, occupation, gender, and education were identified as significant factors linked to PET-bottled beverage consumption, while income was not a significant factor. 90% Of post-consumed PET bottles were collected by informal collectors (i.e., scavengers and itinerant waste buyers). The survey also found that nearly all PET bottles were reprocessed by small factories that were not designed with pollution control equipment, which allows them to offer higher prices for waste recyclable bottles. As Beijing is trying to build a formal recycling collection system for recyclables, subsidies should be given to the formal recycling sector rather than being charged land use fees, and attention should also be given to informal recyclers that make their living from the collection of recyclables. Informal and formal sectors may work together by employing the scavengers and itinerant waste buyers for the formal sectors. In addition to the recycling of PET bottles, concern should also be allocated to reduce consumption, especially among young people, as they, compared to other groups, have a stronger demand for PET-bottled beverages and will be the main body of society. Copyright © 2013 Elsevier Ltd. All rights reserved.

  19. Detailed comparison of amyloid PET and CSF biomarkers for identifying early Alzheimer disease

    PubMed Central

    Zetterberg, Henrik; Mattsson, Niklas; Johansson, Per; Minthon, Lennart; Blennow, Kaj; Olsson, Mattias

    2015-01-01

    Objective: To compare the diagnostic accuracy of CSF biomarkers and amyloid PET for diagnosing early-stage Alzheimer disease (AD). Methods: From the prospective, longitudinal BioFINDER study, we included 122 healthy elderly and 34 patients with mild cognitive impairment who developed AD dementia within 3 years (MCI-AD). β-Amyloid (Aβ) deposition in 9 brain regions was examined with [18F]-flutemetamol PET. CSF was analyzed with INNOTEST and EUROIMMUN ELISAs. The results were replicated in 146 controls and 64 patients with MCI-AD from the Alzheimer's Disease Neuroimaging Initiative study. Results: The best CSF measures for identifying MCI-AD were Aβ42/total tau (t-tau) and Aβ42/hyperphosphorylated tau (p-tau) (area under the curve [AUC] 0.93–0.94). The best PET measures performed similarly (AUC 0.92–0.93; anterior cingulate, posterior cingulate/precuneus, and global neocortical uptake). CSF Aβ42/t-tau and Aβ42/p-tau performed better than CSF Aβ42 and Aβ42/40 (AUC difference 0.03–0.12, p < 0.05). Using nonoptimized cutoffs, CSF Aβ42/t-tau had the highest accuracy of all CSF/PET biomarkers (sensitivity 97%, specificity 83%). The combination of CSF and PET was not better than using either biomarker separately. Conclusions: Amyloid PET and CSF biomarkers can identify early AD with high accuracy. There were no differences between the best CSF and PET measures and no improvement when combining them. Regional PET measures were not better than assessing the global Aβ deposition. The results were replicated in an independent cohort using another CSF assay and PET tracer. The choice between CSF and amyloid PET biomarkers for identifying early AD can be based on availability, costs, and doctor/patient preferences since both have equally high diagnostic accuracy. Classification of evidence: This study provides Class III evidence that amyloid PET and CSF biomarkers identify early-stage AD equally accurately. PMID:26354982

  20. 68Ga PSMA-11 PET with CT urography protocol in the initial staging and biochemical relapse of prostate cancer.

    PubMed

    Iravani, Amir; Hofman, Michael S; Mulcahy, Tony; Williams, Scott; Murphy, Declan; Parameswaran, Bimal K; Hicks, Rodney J

    2017-12-21

    68 Ga-labelled prostate specific membrane antigen (PSMA) ligand PET/CT is a promising modality in primary staging (PS) and biochemical relapse (BCR) of prostate cancer (PC). However, pelvic nodes or local recurrences can be difficult to differentiate from radioactive urine. CT urography (CT-U) is an established method, which allows assessment of urological malignancies. The study presents a novel protocol of 68 Ga-PSMA-11 PET/CT-U in PS and BCR of PC. A retrospective review of PSMA PET/CT-U preformed on 57 consecutive patients with prostate cancer. Fifty mL of IV contrast was administered 10 min (range 8-15) before the CT component of a combined PET/CT study, acquired approximately 60 min (range 40-85) after administration of 166 MBq (range 91-246) of 68 Ga-PSMA-11. PET and PET/CT-U were reviewed by two nuclear medicine physicians and CT-U by a radiologist. First, PET images were reviewed independently followed by PET/CT-U images. Foci of activity which could not unequivocally be assessed as disease or urinary activity were recorded. PET/CT-U was considered of potential benefit in final interpretation when the equivocal focal activity in PET images corresponded to opacified ureter, bladder, prostate bed, seminal vesicles, or urethra. Student's T test and Pearson's correlation coefficient was used for assessment of variables including lymph node size and standardized uptake value. Overall 50 PSMA PET/CT-U studies were performed for BCR and 7 for PS. Median PSA with BCR and PS were 2.0 ± 11.4 ng/ml (0.06-57.3 ng/ml) and 18 ± 35.3 ng/ml (6.8-100 ng/ml), respectively. The median Gleason-score for both groups was 7 (range 6-10). In BCR group, PSMA PET was reported positive in 36 (72%) patients, CT-U in 11(22%) patients and PET/CT-U in 33 (66%) patients. In PS group, PSMA PET detected the primary site in all seven patients, of which one patient with metastatic nodal disease had negative CT finding. Of 40 equivocal foci (27/57 patients) on PET, 11 foci (10/57 patients, 17.5%) were localized to enhanced urine on PET/CT-U, hence considered of potential benefit in interpretation. Of those, 3 foci (3 patients) were solitary sites of activity on PSMA imaging including two local and one nodal site and 4 foci (3 patients) were in different nodal fields. PET/CT-U protocol is a practical approach and may assist in interpretation of 68 Ga-PSMA-11 imaging by delineation of the contrast opacified genitourinary system and matching focal PSMA activity with urinary contrast.

  1. Optimization of yttrium-90 PET for simultaneous PET/MR imaging: A phantom study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Eldib, Mootaz

    2016-08-15

    Purpose: Positron emission tomography (PET) imaging of yttrium-90 in the liver post radioembolization has been shown useful for personalized dosimetry calculations and evaluation of extrahepatic deposition. The purpose of this study was to quantify the benefits of several MR-based data correction approaches offered by using a combined PET/MR system to improve Y-90 PET imaging. In particular, the feasibility of motion and partial volume corrections were investigated in a controlled phantom study. Methods: The ACR phantom was filled with an initial concentration of 8 GBq of Y-90 solution resulting in a contrast of 10:1 between the hot cylinders and the background.more » Y-90 PET motion correction through motion estimates from MR navigators was evaluated by using a custom-built motion stage that simulated realistic amplitudes of respiration-induced liver motion. Finally, the feasibility of an MR-based partial volume correction method was evaluated using a wavelet decomposition approach. Results: Motion resulted in a large (∼40%) loss of contrast recovery for the 8 mm cylinder in the phantom, but was corrected for after MR-based motion correction was applied. Partial volume correction improved contrast recovery by 13% for the 8 mm cylinder. Conclusions: MR-based data correction improves Y-90 PET imaging on simultaneous PET/MR systems. Assessment of these methods must be studied further in the clinical setting.« less

  2. Hybrid cardiac imaging using PET/MRI: a joint position statement by the European Society of Cardiovascular Radiology (ESCR) and the European Association of Nuclear Medicine (EANM).

    PubMed

    Nensa, Felix; Bamberg, Fabian; Rischpler, Christoph; Menezes, Leon; Poeppel, Thorsten D; la Fougère, Christian; Beitzke, Dietrich; Rasul, Sazan; Loewe, Christian; Nikolaou, Konstantin; Bucerius, Jan; Kjaer, Andreas; Gutberlet, Matthias; Prakken, Niek H; Vliegenthart, Rozemarijn; Slart, Riemer H J A; Nekolla, Stephan G; Lassen, Martin L; Pichler, Bernd J; Schlosser, Thomas; Jacquier, Alexis; Quick, Harald H; Schäfers, Michael; Hacker, Marcus

    2018-05-02

    Positron emission tomography (PET) and magnetic resonance imaging (MRI) have both been used for decades in cardiovascular imaging. Since 2010, hybrid PET/MRI using sequential and integrated scanner platforms has been available, with hybrid cardiac PET/MR imaging protocols increasingly incorporated into clinical workflows. Given the range of complementary information provided by each method, the use of hybrid PET/MRI may be justified and beneficial in particular clinical settings for the evaluation of different disease entities. In the present joint position statement, we critically review the role and value of integrated PET/MRI in cardiovascular imaging, provide a technical overview of cardiac PET/MRI and practical advice related to the cardiac PET/MRI workflow, identify cardiovascular applications that can potentially benefit from hybrid PET/MRI, and describe the needs for future development and research. In order to encourage its wide dissemination, this article is freely accessible on the European Radiology and European Journal of Hybrid Imaging web sites. • Studies and case-reports indicate that PET/MRI is a feasible and robust technology. • Promising fields of application include a variety of cardiac conditions. • Larger studies are required to demonstrate its incremental and cost-effective value. • The translation of novel radiopharmaceuticals and MR-sequences will provide exciting new opportunities.

  3. Hybrid FDG-PET/MR compared to FDG-PET/CT in adult lymphoma patients.

    PubMed

    Atkinson, Wendy; Catana, Ciprian; Abramson, Jeremy S; Arabasz, Grae; McDermott, Shanaugh; Catalano, Onofrio; Muse, Victorine; Blake, Michael A; Barnes, Jeffrey; Shelly, Martin; Hochberg, Ephraim; Rosen, Bruce R; Guimaraes, Alexander R

    2016-07-01

    The goal of this study is to evaluate the diagnostic performance of simultaneous FDG-PET/MR including diffusion compared to FDG-PET/CT in patients with lymphoma. Eighteen patients with a confirmed diagnosis of non-Hodgkin's (NHL) or Hodgkin's lymphoma (HL) underwent an IRB-approved, single-injection/dual-imaging protocol consisting of a clinical FDG-PET/CT and subsequent FDG-PET/MR scan. PET images from both modalities were reconstructed iteratively. Attenuation correction was performed using low-dose CT data for PET/CT and Dixon-MR sequences for PET/MR. Diffusion-weighted imaging was performed. SUVmax was measured and compared between modalities and the apparent diffusion coefficient (ADC) using ROI analysis by an experienced radiologist using OsiriX. Strength of correlation between variables was measured using the Pearson correlation coefficient (r p). Of the 18 patients included in this study, 5 had HL and 13 had NHL. The median age was 51 ± 14.8 years. Sixty-five FDG-avid lesions were identified. All FDG-avid lesions were visible with comparable contrast, and therefore initial and follow-up staging was identical between both examinations. SUVmax from FDG-PET/MR [(mean ± sem) (21.3 ± 2.07)] vs. FDG-PET/CT (mean 23.2 ± 2.8) demonstrated a strongly positive correlation [r s = 0.95 (0.94, 0.99); p < 0.0001]. There was no correlation found between ADCmin and SUVmax from FDG-PET/MR [r = 0.17(-0.07, 0.66); p = 0.09]. FDG-PET/MR offers an equivalent whole-body staging examination as compared with PET/CT with an improved radiation safety profile in lymphoma patients. Correlation of ADC to SUVmax was weak, understating their lack of equivalence, but not undermining their potential synergy and differing importance.

  4. Quantitative Comparison of PET and Bremsstrahlung SPECT for Imaging the In Vivo Yttrium-90 Microsphere Distribution after Liver Radioembolization

    PubMed Central

    Elschot, Mattijs; Vermolen, Bart J.; Lam, Marnix G. E. H.; de Keizer, Bart; van den Bosch, Maurice A. A. J.; de Jong, Hugo W. A. M.

    2013-01-01

    Background After yttrium-90 (90Y) microsphere radioembolization (RE), evaluation of extrahepatic activity and liver dosimetry is typically performed on 90Y Bremsstrahlung SPECT images. Since these images demonstrate a low quantitative accuracy, 90Y PET has been suggested as an alternative. The aim of this study is to quantitatively compare SPECT and state-of-the-art PET on the ability to detect small accumulations of 90Y and on the accuracy of liver dosimetry. Methodology/Principal Findings SPECT/CT and PET/CT phantom data were acquired using several acquisition and reconstruction protocols, including resolution recovery and Time-Of-Flight (TOF) PET. Image contrast and noise were compared using a torso-shaped phantom containing six hot spheres of various sizes. The ability to detect extra- and intrahepatic accumulations of activity was tested by quantitative evaluation of the visibility and unique detectability of the phantom hot spheres. Image-based dose estimates of the phantom were compared to the true dose. For clinical illustration, the SPECT and PET-based estimated liver dose distributions of five RE patients were compared. At equal noise level, PET showed higher contrast recovery coefficients than SPECT. The highest contrast recovery coefficients were obtained with TOF PET reconstruction including resolution recovery. All six spheres were consistently visible on SPECT and PET images, but PET was able to uniquely detect smaller spheres than SPECT. TOF PET-based estimates of the dose in the phantom spheres were more accurate than SPECT-based dose estimates, with underestimations ranging from 45% (10-mm sphere) to 11% (37-mm sphere) for PET, and 75% to 58% for SPECT, respectively. The differences between TOF PET and SPECT dose-estimates were supported by the patient data. Conclusions/Significance In this study we quantitatively demonstrated that the image quality of state-of-the-art PET is superior over Bremsstrahlung SPECT for the assessment of the 90Y microsphere distribution after radioembolization. PMID:23405207

  5. Effects of a Pilates exercise program on muscle strength, postural control and body composition: results from a pilot study in a group of post-menopausal women.

    PubMed

    Bergamin, M; Gobbo, S; Bullo, V; Zanotto, T; Vendramin, B; Duregon, F; Cugusi, L; Camozzi, V; Zaccaria, M; Neunhaeuserer, D; Ermolao, A

    2015-12-01

    Participation in exercise programs is heartily recommended for older adults since the level of physical fitness directly influences functional independence. The aim of this present study was to investigate the effects of supervised Pilates exercise training on the physical function, hypothesizing that a period of Pilates exercise training (PET) can increase overall muscle strength, body composition, and balance, during single and dual-task conditions, in a group of post-menopausal women. Twenty-five subjects, aged 59 to 66 years old, were recruited. Eligible participants were assessed prior and after 3 months of PET performed twice per week. Muscular strength was evaluated with handgrip strength (HGS) test, 30-s chair sit-to-stand test (30CST), and abdominal strength (AST) test. Postural control and dual-task performance were measured through a stabilometric platform while dynamic balance with 8 ft up and go test. Finally, body composition was assessed by means of dual-energy X-ray absorptiometry. Statistically significant improvements were detected on HGS (+8.22%), 30CST (+23.41%), 8 ft up and go test (-5.95%), AST (+30.81%), medio-lateral oscillations in open eyes and dual-task condition (-22.03% and -10.37%). Pilates was effective in increasing upper body, lower body, and abdominal muscle strength. No changes on body composition were detected. Results on this investigation indicated also that 12-week of mat Pilates is not sufficient to determine a clinical meaningful improvement on static balance in single and dual-task conditions.

  6. Do TSH, FT3, and FT4 Impact BAT Visualization of Clinical FDG-PET/CT Images?

    PubMed

    Nishii, Ryuichi; Nagamachi, Shigeki; Mizutani, Youichi; Terada, Tamasa; Kiyohara, Syogo; Wakamatsu, Hideyuki; Fujita, Seigo; Higashi, Tatsuya; Yoshinaga, Keiichiro; Saga, Tsuneo; Hirai, Toshinori

    2018-01-01

    We retrospectively analyzed activated BAT visualization on FDG-PET/CT in patients with various conditions and TH levels to clarify the relationships between visualization of BAT on FDG-PET/CT and the effect of TH. Patients who underwent clinical FDG-PET/CT were reviewed and we categorized patients into 5 groups: (i) thyroid hormone withdrawal (THW) group; (ii) recombinant human thyrotropin (rhTSH) group; (iii) hypothyroidism group; (iv) hyperthyroidism group; and (v) BAT group. A total of sixty-two FDG-PET/CT imaging studies in fifty-nine patients were performed. To compare each group, gender; age; body weight; serum TSH, FT3, and FT4 levels; and outside temperature were evaluated. No significant visualization of BAT was noted in any of the images in the THW, rhTSH, hypothyroidism, and hyperthyroidism groups. All patients in the BAT group were in a euthyroid state. When the BAT-negative and BAT-positive patient groups were compared, it was noted that the minimum and maximum temperature on the day of the PET study and maximum temperature of the one day before the PET study were significantly lower in BAT-positive group than in all those of other groups. Elevated TSH condition before RIT, hyperthyroidism, or hypothyroidism did not significantly impact BAT visualization of clinical FDG-PET/CT images.

  7. Self-consolidating concretes containing waste PET bottles as sand replacement

    NASA Astrophysics Data System (ADS)

    Khalid, Faisal Sheikh; Azmi, Nurul Bazilah; Mazenan, Puteri Natasya; Shahidan, Shahiron; Othman, Nor hazurina; Guntor, Nickholas Anting Anak

    2018-02-01

    This study evaluates the effect of self-consolidating concrete (SCC) containing waste polyethylene terephthalate (PET) granules on the fresh, mechanical and water absorption properties. Fine aggregates were replaced from 0% to 8% by PET granules. The fresh properties of SCC containing PET granules were determined using slump flow and V-funnel flow time tests. The compressive and splitting tensile strength were evaluated. The results indicated that utilization of waste PET granules in production of SCC could be an effective way for recycling purpose. The maximum amount of PET replacement should be limited to 5%. Exceeding 5% of PET content may result in an increase of V-funnel flow time to overpass the limiting value, decrease in strength. The production of high performance SCC containing 5% PET granules satisfies all the requirements for SCC with satisfactory outputs.

  8. Advances in PET Imaging of P-Glycoprotein Function at the Blood-Brain Barrier

    PubMed Central

    2012-01-01

    Efflux transporter P-glycoprotein (P-gp) at the blood-brain barrier (BBB) restricts substrate compounds from entering the brain and may thus contribute to pharmacoresistance observed in patient groups with refractory epilepsy and HIV. Altered P-gp function has also been implicated in neurodegenerative diseases such as Alzheimer’s and Parkinson’s disease. Positron emission tomography (PET), a molecular imaging modality, has become a promising method to study the role of P-gp at the BBB. The first PET study of P-gp function was conducted in 1998, and during the past 15 years two main categories of P-gp PET tracers have been investigated: tracers that are substrates of P-gp efflux and tracers that are inhibitors of P-gp function. PET, as a noninvasive imaging technique, allows translational research. Examples of this are preclinical investigations of P-gp function before and after administering P-gp modulating drugs, investigations in various animal and disease models, and clinical investigations regarding disease and aging. The objective of the present review is to give an overview of available PET radiotracers for studies of P-gp and to discuss how such studies can be designed. Further, the review summarizes results from PET studies of P-gp function in different central nervous system disorders. PMID:23421673

  9. 7. Survey of Results of Whole Body Imaging Using the PET/CT at the University of Pittsburgh Medical Center PET Facility.

    PubMed

    Martinelli; Townsend; Meltzer; Villemagne

    2000-07-01

    Purpose: At the University Of Pittsburgh Medical Center, over 100 oncology studies have been performed using a combined PET/CT scanner. The scanner is a prototype, which combines clinical PET and clinical CT imaging in a single unit. The sensitivity achieved using three-dimensional PET imaging as well as the use of the CT for attenuation correction and image fusion make the device ideal for clinical oncology. Clinical indications imaged on the PET/CT scanner include, but are not limited to, tumor staging, solitary pulmonary nodule evaluation, and evaluation of tumor reoccurrence in melanoma, lymphoma, colorectal cancer, lung cancer, pancreatic cancer, head and neck cancer, and renal cancer.Methods: For all studies, seven millicuries of F(18)-fluorodeoxyglucose is injected and a forty-five minute uptake period is allowed prior to positioning the patient in the scanner. A helical CT scan is acquired over the region, or regions of interest followed by a multi-bed whole body PET scan for the same axial extent. The CT scan is used to correct the PET data for attenuation. The entire imaging session lasts 1-1.5 hours depending on the number of beds acquired, and is generally well tolerated by the patient.Results and Conclusion: Based on our experience in over 100 studies, combined PET/CT imaging offers significant advantages, including more accurate localization of focal uptake, distinction of pathology from normal physiological uptake, and improvements in evaluating therapy. These benefits will be illustrated with a number of representative, fully documented studies.

  10. Radiotherapy planning: PET/CT scanner performances in the definition of gross tumour volume and clinical target volume.

    PubMed

    Brianzoni, Ernesto; Rossi, Gloria; Ancidei, Sergio; Berbellini, Alfonso; Capoccetti, Francesca; Cidda, Carla; D'Avenia, Paola; Fattori, Sara; Montini, Gian Carlo; Valentini, Gianluca; Proietti, Alfredo; Algranati, Carlo

    2005-12-01

    Positron emission tomography is the most advanced scintigraphic imaging technology and can be employed in the planning of radiation therapy (RT). The aim of this study was to evaluate the possible role of fused images (anatomical CT and functional FDG-PET), acquired with a dedicated PET/CT scanner, in delineating gross tumour volume (GTV) and clinical target volume (CTV) in selected patients and thus in facilitating RT planning. Twenty-eight patients were examined, 24 with lung cancer (17 non-small cell and seven small cell) and four with non-Hodgkin's lymphoma in the head and neck region. All patients underwent a whole-body PET scan after a CT scan. The CT images provided morphological volumetric information, and in a second step, the corresponding PET images were overlaid to define the effective target volume. The images were exported off-line via an internal network to an RT simulator. Three patient were excluded from the study owing to change in the disease stage subsequent to the PET/CT study. Among the remaining 25 patients, PET significantly altered the GTV or CTV in 11 (44%) . In five of these 11 cases there was a reduction in GTV or CTV, while in six there was an increase in GTV or CTV. FDG-PET is a highly sensitive imaging modality that offers better visualisation of local and locoregional tumour extension. This study confirmed that co-registration of CT data and FDG-PET images may lead to significant modifications of RT planning and patient management.

  11. Effect of culture complex of BMSCs and sodium hydroxide- and GRGDSPC-treated PET on the reconstruction of injured anterior cruciate ligament in a rabbit model

    PubMed Central

    Huang, Jianming; Chen, Fengrong; Jian, Guojian; Ye, Zhiyang; Wang, Zimin; Liu, Haoyuan; Kang, Yifan

    2015-01-01

    Ligament reconstruction is an effective therapy for anterior cruciate ligament (ACL) rupture. Polyethylene terephthalate (PET) artificial ligaments have recently gained popularity in clinical ACL reconstruction for its advantage in the improvement of keen function. However, the application of PET in clinical treatment is limited by its poor bioactivity and biocompatibility. Recently, bone marrow-derived mesenchymal stem cells (BMSCs) have been widely studied in regenerative medical therapy due to their multi-lineage differentiation. Previous study also indicated that BMSCs may promote the healing of tendon-bone interface of injured ligament. We speculate that BMSCs may enhance the curative effect of PET artificial ligament on the tendon-bone-healing in ligament reconstruction. In this study, the PET materials were first modified with sodium hydroxide hydrolysis and GRGDSPC peptide which was able to improve its bioactivity and biocompatibility. Then, the effects of modified PET materials on the adhesion, proliferation and differentiation of BMSCs were examined. The in vitro co-culture of BMSCs and modified PET showed the modified PET promoted the adhesion, proliferation and differentiation of BMSCs. Further, the effect of culture complex of BMSCs and modified PET artificial ligament co-culture system on the injured ligament reconstruction was investigated in vivo. Results showed not only better growth and differentiation of BMSCs but also satisfactory healing of the injured ligament was observed after implantation of this culture complex into the injured ligament of rabbits. Our study provides a brand-new solution for ACL reconstruction. PMID:26221227

  12. 89Zr-bevacizumab PET visualizes heterogeneous tracer accumulation in tumor lesions of renal cell carcinoma patients and differential effects of antiangiogenic treatment.

    PubMed

    Oosting, Sjoukje F; Brouwers, Adrienne H; van Es, Suzanne C; Nagengast, Wouter B; Oude Munnink, Thijs H; Lub-de Hooge, Marjolijn N; Hollema, Harry; de Jong, Johan R; de Jong, Igle J; de Haas, Sanne; Scherer, Stefan J; Sluiter, Wim J; Dierckx, Rudi A; Bongaerts, Alfons H H; Gietema, Jourik A; de Vries, Elisabeth G E

    2015-01-01

    No validated predictive biomarkers for antiangiogenic treatment of metastatic renal cell carcinoma (mRCC) exist. Tumor vascular endothelial growth factor A (VEGF-A) level may be useful. We determined tumor uptake of (89)Zr-bevacizumab, a VEGF-A-binding PET tracer, in mRCC patients before and during antiangiogenic treatment in a pilot study. Patients underwent (89)Zr-bevacizumab PET scans at baseline and 2 and 6 wk after initiating either bevacizumab (10 mg/kg every 2 wk) with interferon-α (3-9 million IU 3 times/wk) (n = 11) or sunitinib (50 mg daily, 4 of every 6 wk) (n = 11). Standardized uptake values were compared with plasma VEGF-A and time to disease progression. (89)Zr-bevacizumab PET scans visualized 125 evaluable tumor lesions in 22 patients, with a median SUV(max) (maximum standardized uptake value) of 6.9 (range, 2.3-46.9). Bevacizumab/interferon-α induced a mean change in tumor SUV(max) of -47.0% (range, -84.7 to +20.0%; P < 0.0001) at 2 wk and an additional -9.7% (range, -44.8 to +38.9%; P = 0.015) at 6 wk. In the sunitinib group, the mean change in tumor SUV(max) was -14.3% at 2 wk (range, -80.4 to +269.9; P = 0.006), but at 6 wk the mean change in tumor SUV(max) was +72.6% (range, -46.4 to +236%; P < 0.0001) above baseline. SUV(max) was not related to plasma VEGF-A at all scan moments. A baseline mean tumor SUV(max) greater than 10.0 in the 3 most intense lesions corresponded with longer time to disease progression (89.7 vs. 23.0 wk; hazard ratio, 0.22; 95% confidence interval, 0.05-1.00). Tumor uptake of (89)Zr-bevacizumab is high in mRCC, with remarkable interpatient and intrapatient heterogeneity. Bevacizumab/interferon-α strongly decreases tumor uptake whereas sunitinib results in a modest reduction with an overshoot after 2 drug-free weeks. High baseline tumor SUV(max) was associated with longer time to progression. © 2015 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  13. Amino acid tracers in PET imaging of diffuse low-grade gliomas: a systematic review of preoperative applications.

    PubMed

    Näslund, Olivia; Smits, Anja; Förander, Petter; Laesser, Mats; Bartek, Jiri; Gempt, Jens; Liljegren, Ann; Daxberg, Eva-Lotte; Jakola, Asgeir Store

    2018-05-24

    Positron emission tomography (PET) imaging using amino acid tracers has in recent years become widely used in the diagnosis and prediction of disease course in diffuse low-grade gliomas (LGG). However, implications of preoperative PET for treatment and prognosis in this patient group have not been systematically studied. The aim of this systematic review was to evaluate the preoperative diagnostic and prognostic value of amino acid PET in suspected diffuse LGG. Medline, Cochrane Library, and Embase databases were systematically searched using keywords "PET," "low-grade glioma," and "amino acids tracers" with their respective synonyms. Out of 2137 eligible studies, 28 met the inclusion criteria. Increased amino acid uptake (lesion/brain) was consistently reported among included studies; in 25-92% of subsequently histopathology-verified LGG, in 83-100% of histopathology-verified HGG, and also in some non-neoplastic lesions. No consistent results were found in studies reporting hot spot areas on PET in MRI-suspected LGG. Thus, the diagnostic value of amino acid PET imaging in suspected LGG has proven difficult to interpret, showing clear overlap and inconsistencies among reported results. Similarly, the results regarding the prognostic value of PET in suspected LGG and the correlation between uptake ratios and the molecular tumor status of LGG were conflicting. This systematic review illustrates the difficulties with prognostic studies presenting data on group-level without adjustment for established clinical prognostic factors, leading to a loss of additional prognostic information. We conclude that the prognostic value of PET is limited to analysis of histological subgroups of LGG and is probably strongest when using kinetic analysis of dynamic FET uptake parameters.

  14. EXPLORER: Changing the molecular imaging paradigm with total-body PET/CT (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Cherry, Simon R.; Badawi, Ramsey D.; Jones, Terry

    2016-04-01

    Positron emission tomography (PET) is the highest sensitivity technique for human whole-body imaging studies. However, current clinical PET scanners do not make full use of the available signal, as they only permit imaging of a 15-25 cm segment of the body at one time. Given the limited sensitive region, whole-body imaging with clinical PET scanners requires relatively long scan times and subjects the patient to higher than necessary radiation doses. The EXPLORER initiative aims to build a 2-meter axial length PET scanner to allow imaging the entire subject at once, capturing nearly the entire available PET signal. EXPLORER will acquire data with ~40-fold greater sensitivity leading to a six-fold increase in reconstructed signal-to-noise ratio for imaging the total body. Alternatively, total-body images with the EXPLORER scanner will be able to be acquired in ~30 seconds or with ~0.15 mSv injected dose, while maintaining current PET image quality. The superior sensitivity will open many new avenues for biomedical research. Specifically for cancer applications, high sensitivity PET will enable detection of smaller lesions. Additionally, greater sensitivity will allow imaging out to 10 half-lives of positron emitting radiotracers. This will enable 1) metabolic ultra-staging with FDG by extending the uptake and clearance time to 3-5 hours to significantly improve contrast and 2) improved kinetic imaging with short-lived radioisotopes such as C-11, crucial for drug development studies. Frequent imaging studies of the same subject to study disease progression or to track response to therapy will be possible with the low dose capabilities of the EXPLORER scanner. The low dose capabilities will also open up new imaging possibilities in pediatrics and adolescents to better study developmental disorders. This talk will review the basis for developing total-body PET, potential applications, and review progress to date in developing EXPLORER, the first total-body PET scanner.

  15. Staging performance of whole-body DWI, PET/CT and PET/MRI in invasive ductal carcinoma of the breast.

    PubMed

    Catalano, Onofrio Antonio; Daye, Dania; Signore, Alberto; Iannace, Carlo; Vangel, Mark; Luongo, Angelo; Catalano, Marco; Filomena, Mazzeo; Mansi, Luigi; Soricelli, Andrea; Salvatore, Marco; Fuin, Niccolo; Catana, Ciprian; Mahmood, Umar; Rosen, Bruce Robert

    2017-07-01

    The aim of the present study was to evaluate the performance of whole-body diffusion-weighted imaging (WB-DWI), whole-body positron emission tomography with computed tomography (WB-PET/CT), and whole-body positron emission tomography with magnetic resonance imaging (WB-PET/MRI) in staging patients with untreated invasive ductal carcinoma of the breast. Fifty-one women with newly diagnosed invasive ductal carcinoma of the breast underwent WB-DWI, WB-PET/CT and WB-PET/MRI before treatment. A radiologist and a nuclear medicine physician reviewed in consensus the images from the three modalities and searched for occurrence, number and location of metastases. Final staging, according to each technique, was compared. Pathology and imaging follow-up were used as the reference. WB-DWI, WB-PET/CT and WB-PET/MRI correctly and concordantly staged 33/51 patients: stage IIA in 7 patients, stage IIB in 8 patients, stage IIIC in 4 patients and stage IV in 14 patients. WB-DWI, WB-PET/CT and WB-PET/MRI incorrectly and concordantly staged 1/51 patient as stage IV instead of IIIA. Discordant staging was reported in 17/51 patients. WB-PET/MRI resulted in improved staging when compared to WB-PET/CT (50 correctly staged on WB-PET/MRI vs. 38 correctly staged on WB-PET/CT; McNemar's test; p<0.01). Comparing the performance of WB-PET/MRI and WB-DWI (43 correct) did not reveal a statistically significant difference (McNemar test, p=0.14). WB-PET/MRI is more accurate in the initial staging of breast cancer than WB-DWI and WB-PET/CT, however, the discrepancies between WB-PET/MRI and WB-DWI were not statistically significant. When available, WB-PET/MRI should be considered for staging patient with invasive ductal breast carcinoma.

  16. Reproducibility of 18F-FDG PET uptake measurements in head and neck squamous cell carcinoma on both PET/CT and PET/MR

    PubMed Central

    Fischer, B M; Aznar, M C; Hansen, A E; Vogelius, I R; Löfgren, J; Andersen, F L; Loft, A; Kjaer, A; Højgaard, L; Specht, L

    2015-01-01

    Objective: To investigate reproducibility of fluorine-18 fludeoxyglucose (18F-FDG) uptake on 18F-FDG positron emission tomography (PET)/CT and 18F-FDG PET/MR scans in patients with head and neck squamous cell carcinoma (HNSCC). Methods: 30 patients with HNSCC were included in this prospective study. The patients were scanned twice before radiotherapy treatment with both PET/CT and PET/MR. Patients were scanned on the same scanners, 3 days apart and according to the same protocol. Metabolic tumour activity was measured by the maximum and peak standardized uptake value (SUVmax and SUVpeak, respectively), and total lesion glycolysis from the metabolic tumour volume defined from ≥50% SUVmax. Bland–Altman analysis with limits of agreement, coefficient of variation (CV) from the two modalities were performed in order to test the reproducibility. Furthermore, CVs from SUVmax and SUVpeak were compared. The area under the curve from cumulative SUV–volume histograms were measured and tested for reproducibility of the distribution of 18F-FDG uptake. Results: 24 patients had two pre-treatment PET/CT scans and 21 patients had two pre-treatment PET/MR scans available for further analyses. Mean difference for SUVmax, peak and mean was approximately 4% for PET/CT and 3% for PET/MR, with 95% limits of agreement less than ±20%. CV was small (5–7%) for both modalities. There was no significant difference in CVs between PET/CT and PET/MR (p = 0.31). SUVmax was not more reproducible than SUVpeak (p = 0.09). Conclusion: 18F-FDG uptake in PET/CT and PET/MR is highly reproducible and we found no difference in reproducibility between PET/CT and PET/MR. Advances in knowledge: This is the first report to test reproducibility of PET/CT and PET/MR. PMID:25634069

  17. Pets and Human Health in Germany and Australia: National Longitudinal Results

    ERIC Educational Resources Information Center

    Headey, Bruce; Grabka, Markus M.

    2007-01-01

    The German and Australian "longitudinal" surveys analysed here are the first national representative surveys to show that (1) people who continuously own a pet are the healthiest group and (2) people who cease to have a pet or never had one are less healthy. Most previous studies which have claimed that pets confer health benefits were…

  18. Detection of osseous metastasis by 18F-NaF/18F-FDG PET/CT versus CT alone.

    PubMed

    Sampath, Srinath C; Sampath, Srihari C; Mosci, Camila; Lutz, Amelie M; Willmann, Juergen K; Mittra, Erik S; Gambhir, Sanjiv S; Iagaru, Andrei

    2015-03-01

    Sodium fluoride PET (18F-NaF) has recently reemerged as a valuable method for detection of osseous metastasis, with recent work highlighting the potential of coadministered 18F-NaF and 18F-FDG PET/CT in a single combined imaging examination. We further examined the potential of such combined examinations by comparing dual tracer 18F-NaF18/F-FDG PET/CT with CT alone for detection of osseous metastasis. Seventy-five participants with biopsy-proven malignancy were consecutively enrolled from a single center and underwent combined 18F-NaF/18F-FDG PET/CT and diagnostic CT scans. PET/CT as well as CT only images were reviewed in blinded fashion and compared with the results of clinical, imaging, or histological follow-up as a truth standard. Sensitivity of the combined 18F-NaF/18F-FDG PET/CT was higher than that of CT alone (97.4% vs 66.7%). CT and 18F-NaF/18F-FDG PET/CT were concordant in 73% of studies. Of 20 discordant cases, 18F-NaF/18F-FDG PET/CT was correct in 19 (95%). Three cases were interpreted concordantly but incorrectly, and all 3 were false positives. A single case of osseous metastasis was detected by CT alone, but not by 18F-NaF/18F-FDG PET/CT. Combined 18F-NaF/18F-FDG PET/CT outperforms CT alone and is highly sensitive and specific for detection of osseous metastases. The concordantly interpreted false-positive cases demonstrate the difficulty of distinguishing degenerative from malignant disease, whereas the single case of metastasis seen on CT but not PET highlights the need for careful review of CT images in multimodality studies.

  19. Whole-Body 68Ga-DOTANOC PET/MRI Versus 68Ga-DOTANOC PET/CT in Patients With Neuroendocrine Tumors

    PubMed Central

    Berzaczy, Dominik; Giraudo, Chiara; Haug, Alexander R.; Raderer, Markus; Senn, Daniela; Karanikas, Georgios; Weber, Michael; Mayerhoefer, Marius E.

    2017-01-01

    Purpose The aim of this study was to assess the diagnostic performance of simultaneous whole-body 68Ga-DOTANOC PET/MRI compared with 68Ga-DOTANOC PET/CT for detection of distant metastatic disease in patients with well-differentiated neuroendocrine tumors (NETs). Methods Patients with histologically proven, well-differentiated NET (G1 or G2) were included in this prospective, institutional review board–approved study. Patients underwent 68Ga-DOTANOC PET/CT and subsequent 68Ga-DOTANOC PET/MRI after a single tracer injection on the same day for staging or restaging purposes. Images were evaluated for the presence of NET lesions by 2 rater teams, each consisting of a nuclear medicine physician and a radiologist, in an observer-blinded fashion. Overall agreement, accuracy, sensitivity, and specificity, relative to a composite reference standard (consensus review including follow-up data), were calculated. Results Between July 2014 and June 2016, 28 patients were enrolled. Overall agreement and accuracy between the 2 rater teams were 91.7% (95% confidence interval [CI], 87.5%–95.9%) and 97% (95% CI, 94.4%–99.6%) for PET/MRI and 92.3% (95% CI, 88.3%–96.3%) and 94.6% (95% CI, 91.2%–98.1%) for PET/CT, respectively (P = 1.00). Overall, PET/MRI reached 89.8% sensitivity (95% CI, 77.8%–96.6%) and 100% specificity (95% CI, 97%–100%); PET/CT showed 81.6% sensitivity (95% CI, 68%–91.2%) and 100% specificity (95% CI, 97%–100%) for the detection of metastatic disease in NETs. Conclusions Whole-body 68Ga-DOTANOC PET/MRI appears to be comparable to 68Ga-DOTANOC PET/CT for lesion detection in patients with well-differentiated NETs. PMID:28682844

  20. Towards Implementing an MR-based PET Attenuation Correction Method for Neurological Studies on the MR-PET Brain Prototype

    PubMed Central

    Catana, Ciprian; van der Kouwe, Andre; Benner, Thomas; Michel, Christian J.; Hamm, Michael; Fenchel, Matthias; Fischl, Bruce; Rosen, Bruce; Schmand, Matthias; Sorensen, A. Gregory

    2013-01-01

    A number of factors have to be considered for implementing an accurate attenuation correction (AC) in a combined MR-PET scanner. In this work, some of these challenges were investigated and an AC method based entirely on the MR data obtained with a single dedicated sequence was developed and used for neurological studies performed with the MR-PET human brain scanner prototype. Methods The focus was on the bone/air segmentation problem, the bone linear attenuation coefficient selection and the RF coil positioning. The impact of these factors on the PET data quantification was studied in simulations and experimental measurements performed on the combined MR-PET scanner. A novel dual-echo ultra-short echo time (DUTE) MR sequence was proposed for head imaging. Simultaneous MR-PET data were acquired and the PET images reconstructed using the proposed MR-DUTE-based AC method were compared with the PET images reconstructed using a CT-based AC. Results Our data suggest that incorrectly accounting for the bone tissue attenuation can lead to large underestimations (>20%) of the radiotracer concentration in the cortex. Assigning a linear attenuation coefficient of 0.143 or 0.151 cm−1 to bone tissue appears to give the best trade-off between bias and variability in the resulting images. Not identifying the internal air cavities introduces large overestimations (>20%) in adjacent structures. Based on these results, the segmented CT AC method was established as the “silver standard” for the segmented MR-based AC method. Particular to an integrated MR-PET scanner, ignoring the RF coil attenuation can cause large underestimations (i.e. up to 50%) in the reconstructed images. Furthermore, the coil location in the PET field of view has to be accurately known. Good quality bone/air segmentation can be performed using the DUTE data. The PET images obtained using the MR-DUTE- and CT-based AC methods compare favorably in most of the brain structures. Conclusion An MR-DUTE-based AC method was implemented considering all these factors and our preliminary results suggest that this method could potentially be as accurate as the segmented CT method and it could be used for quantitative neurological MR-PET studies. PMID:20810759

  1. Toward implementing an MRI-based PET attenuation-correction method for neurologic studies on the MR-PET brain prototype.

    PubMed

    Catana, Ciprian; van der Kouwe, Andre; Benner, Thomas; Michel, Christian J; Hamm, Michael; Fenchel, Matthias; Fischl, Bruce; Rosen, Bruce; Schmand, Matthias; Sorensen, A Gregory

    2010-09-01

    Several factors have to be considered for implementing an accurate attenuation-correction (AC) method in a combined MR-PET scanner. In this work, some of these challenges were investigated, and an AC method based entirely on the MRI data obtained with a single dedicated sequence was developed and used for neurologic studies performed with the MR-PET human brain scanner prototype. The focus was on the problem of bone-air segmentation, selection of the linear attenuation coefficient for bone, and positioning of the radiofrequency coil. The impact of these factors on PET data quantification was studied in simulations and experimental measurements performed on the combined MR-PET scanner. A novel dual-echo ultrashort echo time (DUTE) MRI sequence was proposed for head imaging. Simultaneous MR-PET data were acquired, and the PET images reconstructed using the proposed DUTE MRI-based AC method were compared with the PET images that had been reconstructed using a CT-based AC method. Our data suggest that incorrectly accounting for the bone tissue attenuation can lead to large underestimations (>20%) of the radiotracer concentration in the cortex. Assigning a linear attenuation coefficient of 0.143 or 0.151 cm(-1) to bone tissue appears to give the best trade-off between bias and variability in the resulting images. Not identifying the internal air cavities introduces large overestimations (>20%) in adjacent structures. On the basis of these results, the segmented CT AC method was established as the silver standard for the segmented MRI-based AC method. For an integrated MR-PET scanner, in particular, ignoring the radiofrequency coil attenuation can cause large underestimations (i.e.,

  2. Whole-body MRI versus 18F-FDG PET/CT for pretherapeutic assessment and staging of lymphoma: a meta-analysis.

    PubMed

    Wang, Danyang; Huo, Yanlei; Chen, Suyun; Wang, Hui; Ding, Yingli; Zhu, Xiaochun; Ma, Chao

    2018-01-01

    18 F-fluorodeoxyglucose ( 18 F-FDG) positron emission tomography/computed tomography (PET/CT) is the reference standard in staging of 18 F-FDG-avid lymphomas; however, there is no recommended functional imaging modality for indolent lymphomas. Therefore, we aimed to compare the performance of whole-body magnetic resonance imaging (WB-MRI) with that of 18 F-FDG PET/CT for lesion detection and initial staging in patients with aggressive or indolent lymphoma. We searched the MEDLINE, EMBASE, and CENTRAL databases for studies that compared WB-MRI with 18 F-FDG PET/CT for lymphoma staging or lesion detection. The methodological quality of the studies was assessed using version 2 of the "Quality Assessment of Diagnostic Accuracy Studies" tool. The pooled staging accuracy ( μ ) of WB-MRI and 18 F-FDG PET/CT for initial staging and for assessing possible heterogeneity ( χ 2 ) across studies were calculated using commercially available software. Eight studies comprising 338 patients were included. In terms of staging, the meta-analytic staging accuracies of WB-MRI and 18 F-FDG PET/CT for Hodgkin lymphoma and aggressive non-Hodgkin lymphoma (NHL) were 98% (95% CI, 94%-100%) and 98% (95% CI, 94%-100%), respectively. The pooled staging accuracy of 18 F-FDG PET/CT dropped to 87% (95% CI, 72%-97%) for staging in patients with indolent lymphoma, whereas that of WB-MRI remained 96% (95% CI, 91%-100%). Subgroup analysis indicated an even lower staging accuracy of 18 F-FDG PET/CT for staging of less FDG-avid indolent NHLs (60%; 95% CI, 23%-92%), in contrast to the superior performance of WB-MRI (98%; 95% CI, 88%-100%). WB-MRI is a promising radiation-free imaging technique that may serve as a viable alternative to 18 F-FDG PET/CT for staging of 18 FDG-avid lymphomas, where 18 F-FDG PET/CT remains the standard of care. Additionally, WB-MRI seems a less histology-dependent functional imaging test than 18 F-FDG PET/CT and may be the imaging test of choice for staging of indolent NHLs with low 18 F-FDG avidity.

  3. Impact of 68Ga-PSMA PET on the Management of Patients with Prostate Cancer: A Systematic Review and Meta-analysis.

    PubMed

    Han, Sangwon; Woo, Sungmin; Kim, Yeon Joo; Suh, Chong Hyun

    2018-04-18

    68 Gallium prostate-specific membrane antigen positron emission tomography ( 68 Ga-PSMA PET) is an emerging imaging modality for assessment of prostate cancer. Recent studies show promising results regarding its ability to detect recurrent or metastatic prostate cancer superior to that of conventional imaging modalities. However, the impact of 68 Ga-PSMA PET on management of patients with prostate cancer has not been well established. To perform a systematic review and meta-analysis to evaluate the impact of 68 Ga-PSMA PET on management of patients with prostate cancer. Pubmed and EMBASE databases were searched up to January 20, 2018. We included studies that reported proportion of management change after 68 Ga-PSMA PET in patients with prostate cancer. The quality of the studies was evaluated using the GRADE system. The proportion of management changes were pooled using random-effects model. Subgroup analyses and meta-regression analyses were performed to explore heterogeneity. Fifteen studies (1163 patients) were included. The pooled proportion of management changes was 54% (95% confidence interval 47-60%). At meta-regression analyses, PET positivity (%) was a significant factor of heterogeneity (p=0.0486). For patients with biochemical failure, the proportion of radiotherapy (from 56% to 61%), surgery (from 1% to 7%), focal therapy (from 1% to 2%), and multimodal treatment (from 2% to 6%) increased, whereas that of systemic treatment (from 26% to 12%) and no treatment (from 14% to 11%) decreased with 68 Ga-PSMA PET. 68 Ga-PSMA PET had a large impact on the management of patients with prostate cancer. Greater PET positivity was associated with higher proportion of management changes. We reviewed all previous studies assessing the impact of 68 Gallium prostate-specific membrane antigen positron emission tomography ( 68 Ga-PSMA PET) in patients with prostate cancer. We found that 68 Ga-PSMA PET altered the management in approximately half of the patients. Copyright © 2018 European Association of Urology. Published by Elsevier B.V. All rights reserved.

  4. Comparative diagnostic value of 18F-fluoride PET-CT versus MRI for skull-base bone invasion in nasopharyngeal carcinoma.

    PubMed

    Le, Yali; Chen, Yu; Zhou, Fan; Liu, Guangfu; Huang, Zhanwen; Chen, Yue

    2016-10-01

    This study compared the diagnostic value of F-fluoride PET-computed tomography (PET-CT) and MRI in skull-base bone erosion in nasopharyngeal carcinoma (NPC) patients. A total of 93 patients with biopsy-confirmed NPC were enrolled, including 68 men and 25 women between 23 and 74 years of age. All patients were evaluated by both F-fluoride PET-CT and MRI, and the interval between the two imaging examinations was less than 20 days. The patients received no treatment either before or between scans. The studies were interpreted by two nuclear medicine physicians or two radiologists with more than 10 years of professional experience who were blinded to both the diagnosis and the results of the other imaging studies. The reference standard was skull-base bone erosion at a 20-week follow-up imaging study. On the basis of the results of the follow-up imaging studies, 52 patients showed skull-base bone erosion. The numbers of true positives, false positives, true negatives, and false negatives with F-fluoride PET-CT were 49, 4, 37, and 3, respectively. The numbers of true positives, false positives, true negatives, and false negatives with MRI were 46, 5, 36, and 6, respectively. The sensitivity, specificity, and crude accuracy of F-fluoride PET-CT were 94.23, 90.24, and 92.47%, respectively; for MRI, these values were 88.46, 87.80, and 88.17%. Of the 52 patients, 43 showed positive findings both on F-fluoride PET-CT and on MRI. Within the patient cohort, F-fluoride PET-CT and MRI detected 178 and 135 bone lesions, respectively. Both F-fluoride PET-CT and MRI have high sensitivity, specificity, and crude accuracy for detecting skull-base bone invasion in patients with NPC. F-fluoride PET-CT detected more lesions than did MRI in the skull-base bone. This suggests that F-fluoride PET-CT has a certain advantage in evaluating the skull-base bone of NPC patients. Combining the two methods could improve the diagnostic accuracy of skull-base bone invasion for NPC.

  5. A simplified radiometabolite analysis procedure for PET radioligands using a solid phase extraction with micellar medium.

    PubMed

    Nakao, Ryuji; Halldin, Christer

    2013-07-01

    A solid phase extraction method has been developed for simple and high-speed direct determination of PET radioligands in plasma. This methodology makes use of a micellar medium and a solid-phase extraction cartridge for displacement of plasma protein bound radioligand and separation of PET radioligands from their radiometabolites without significant preparation. The plasma samples taken from monkey or human during PET measurements were mixed with a micellar eluent containing an anionic surfactant sodium dodecyl sulphate and loaded onto SPE cartridges. The amount of radioactivity corresponding to parent radioligand (retained on the cartridge) and its radioactive metabolites (eluted with micellar eluent) was measured. Under the optimized conditions, excellent separation of target PET radioligands from their radiometabolites was achieved with a single elution and short run-time of 1 min. This method was successfully applied to study the metabolism for (11)C-labelled radioligands in human or monkey plasma. The amount of parent PET radioligands estimated by micellar solid phase extraction strongly corresponded with that determined by radio-LC. The improved throughput permitted the analysis of a large number of plasma samples (up to 13 samples per one PET study) for accurate estimation of metabolite-corrected input function during quantitative PET imaging studies. Solid phase extraction together with micellar medium is fast, sensitive and easy to use, and therefore it is an attractive alternative method to determine relative composition of PET radioligands in plasma. Copyright © 2013 Elsevier Inc. All rights reserved.

  6. Preparation of Hybrid Nanoparticle Nucleating Agents and Their Effects on the Crystallization Behavior of Poly(ethylene terephthalate)

    PubMed Central

    Han, Zhenzhen; Wang, Yao; Wang, Jiuxing; Wang, Shichao; Zhuang, Hongwei; Liu, Jixian; Huang, Linjun; Wang, Yanxin; Wang, Wei; Belfiore, Laurence A.; Tang, Jianguo

    2018-01-01

    In this research contribution, the primary objective was to enhance the crystallization behavior of poly(ethylene terephthalate) (PET). To accomplish this tack, three kinds of new nucleating agents SiO2-diethylene glycol-LMPET (PET-3), SiO2-triethylene glycol–LMPET(PET-4) and SiO2-tetraethylene glycol-LMPET (PET-5) nucleating agents were prepared via grafting different oligomers (diethylene glycol; triethylene glycol and tetraethylene glycol) to the surface of nano-SiO2 and then linking to the low molecular weight poly(ethylene terephthalate) (LMPET). These nano-particle nucleating agents facilitated the crystallization of PET. Differential scanning calorimetry (DSC) studies of the composites that pure PET blended with PET-3, PET-4 and PET-5 indicated that the longer ethoxy segment in the nucleating agents exhibited (i) higher degrees of crystallinity; (ii) faster rates of crystallization; and (iii) higher crystallization temperatures. The Jeziorny method was employed to analyze the non-isothermal crystallization kinetics of the composites. These works demonstrated that the PET-3, PET-4 and PET-5 were attractive nucleating agents for poly(ethylene terephthalate), and the longer the chain length of the ethoxy segment in the nucleating agents, the more efficient the nucleation effect. PMID:29641456

  7. PSMA PET in prostate cancer – a step towards personalized medicine

    PubMed Central

    Bouchelouche, Kirsten; Choyke, Peter L.

    2017-01-01

    Purpose of review Increasing attention is being given to personalized medicine in oncology, where therapies are tailored to the particular characteristics of the individual cancer patient. In recent years, there has been greater focus on PSMA in prostate cancer (PCa) as a target for imaging and therapy with radionuclides. This review highlights the recent advancements in PSMA PET in PCa during the past year. Recent findings Several reports on PSMA PET/CT in PCa patients are demonstrating promising results, especially for detection of biochemical recurrence. 18F-PSMA PET/CT may be superior to 68Ga-PSMA PET/CT. The detection rate of PSMA PET is influenced by PSA level. PSMA PET/CT may have a higher detection rate than choline PET/CT. Only a few reports have been published on PSMA PET/MRI, and this modality remains to be elucidated further. Conclusion Molecular imaging with PSMA PET is paving the way for personalized medicine in PCa. However, large prospective clinical studies are needed to further evaluate the role of PSMA PET/CT and PET/MRI in the clinical workflow of PCa. PSMA is an excellent target for imaging and therapy with radionuclides, and the “image and treat” strategy has the potential to become a milestone in the management of PCa patients. PMID:26967720

  8. RPC PET: Status and perspectives

    NASA Astrophysics Data System (ADS)

    Couceiro, M.; Blanco, A.; Ferreira, Nuno C.; Ferreira Marques, R.; Fonte, P.; Lopes, L.

    2007-10-01

    The status of the resistive plate chamber (RPC)-PET technology for small animals is briefly reviewed and its sensitivity performance for human PET studied through Monte-Carlo simulations. The cost-effectiveness of these detectors and their very good timing characteristics open the possibility to build affordable Time of Flight (TOF)-PET systems with very large fields of view. Simulations suggest that the sensitivity of such systems for human whole-body screening, under reasonable assumptions, may exceed the present crystal-based PET technology by a factor up to 20.

  9. Temporal lobe deficits in murderers: EEG findings undetected by PET.

    PubMed

    Gatzke-Kopp, L M; Raine, A; Buchsbaum, M; LaCasse, L

    2001-01-01

    This study evaluates electroencephalography (EEG) and positron emission tomography (PET) in the same subjects. Fourteen murderers were assessed by using both PET (while they were performing the continuous performance task) and EEG during a resting state. EEG revealed significant increases in slow-wave activity in the temporal, but not frontal, lobe in murderers, in contrast to prior PET findings that showed reduced prefrontal, but not temporal, glucose metabolism. Results suggest that resting EEG shows empirical utility distinct from PET activation findings.

  10. Implement of the Owner Distinction Function for Healing-Type Pet Robots

    NASA Astrophysics Data System (ADS)

    Nambo, Hidetaka; Kimura, Haruhiko; Hirose, Sadaki

    In recent years, a robotics technology is extremely progressive, and robots are widely applied in many fields. One of the most typical robots is a pet robot. The pet robot is based on an animal pet, such as a dog or a cat. Also, it is known that an animal pet has a healing effect. Therefore, the study to apply pet robots to Animal Assisted Therapy instead of an animal pet has begun to be investigated. We, also, have investigated a method of an owner distinction for pet robot, to emphasize a healing effect of pet robots. In this paper, taking account of implementation into pet robots, a real-time owner distinction method is proposed. In the concrete, the method provides a real-time matching algorithm and an oblivion mechanism. The real-time matching means that a matching and a data acquisition are processed simultaneously. The oblivion mechanism is deleting features of owners in the database of the pet robots. Additionally, the mechanism enables to reduce matching costs or size of database and it enables to follow a change of owners. Furthermore, effectivity and a practicality of the method are evaluated by experiments.

  11. Commissioning of the J-PET Detector for Studies of Decays of Positronium Atoms

    NASA Astrophysics Data System (ADS)

    Czerwiński, E.; Dulski, K.; Białas, P.; Curceanu, C.; Gajos, A.; Głowacz, B.; Gorgol, M.; Hiesmayr, B. C.; Jasińska, B.; Kisielewska, D.; Korcyl, G.; Kowalski, P.; Kozik, T.; Krawczyk, N.; Krzemień, W.; Kubicz, E.; Mohammed, M.; Niedźwiecki, Sz.; Pałka, M.; Pawlik-Niedźwiecka, M.; Raczyński, L.; Rudy, Z.; Sharma, N. G.; Sharma, S.; Shopa, R. Y.; Silarski, M.; Skurzok, M.; Wieczorek, A.; Wiślicki, W.; Zgardzińska, B.; Zieliński, M.; Moskal, P.

    The Jagiellonian Positron Emission Tomograph (J-PET) is a detector for medical imaging of the whole human body as well as for physics studies involving detection of electron-positron annihilation into photons. J-PET has high angular and time resolution and allows for measurement of spin of the positronium and the momenta and polarization vectors of annihilation quanta. In this article, we present the potential of the J-PET system for background rejection in the decays of positronium atoms.

  12. Feasibility of biodegradable based packaging used for red meat storage during shelf-life: A pilot study.

    PubMed

    Panseri, S; Martino, P A; Cagnardi, P; Celano, G; Tedesco, D; Castrica, M; Balzaretti, C; Chiesa, L M

    2018-05-30

    This study was designated to ascertain the effectiveness of polylactic acid (PLA) based packaging solution to store red fresh meat during its refrigerated shelf-life. Recently the attention in the packaging industry regarding the use of bioplastics has been shifting from compostable/biodegradable materials toward biobased materials. Steaks obtained from semimembranous muscle of Piemontese beef were packaged in PLA trays closed with a lid made of PLA film and for comparison purposed in a conventional reference package consisting of a amorphous polyethylene terephthalate/polyethylene (APET/PET) trays and wrapped in plastic film of polyvinyl chloride (PVC). The packaging under modified atmosphere MAP was carried out by using a gas mixture of 66% O 2 , 25% CO 2 and 9%N 2 . By using PLA packaging combination it was possible to maintain an optimum red colour together with a reduced content of volatile compounds associated to off-flavours of meat samples particularly related to the oxidation phenomena. Copyright © 2017 Elsevier Ltd. All rights reserved.

  13. Improvement of the Owner Distinction Method for Healing-Type Pet Robots

    NASA Astrophysics Data System (ADS)

    Nambo, Hidetaka; Kimura, Haruhiko; Hara, Mirai; Abe, Koji; Tajima, Takuya

    In order to decrease human stress, Animal Assisted Therapy which applies pets to heal humans is attracted. However, since animals are insanitary and unsafe, it is difficult to practically apply animal pets in hospitals. For the reason, on behalf of animal pets, pet robots have been attracted. Since pet robots would have no problems in sanitation and safety, they are able to be applied as a substitute for animal pets in the therapy. In our previous study where pet robots distinguish their owners like an animal pet, we used a puppet type pet robot which has pressure type touch sensors. However, the accuracy of our method was not sufficient to practical use. In this paper, we propose a method to improve the accuracy of the distinction. The proposed method can be applied for capacitive touch sensors such as installed in AIBO in addition to pressure type touch sensors. Besides, this paper shows performance of the proposed method from experimental results and confirms the proposed method has improved performance of the distinction in the conventional method.

  14. Deformable image registration for multimodal lung-cancer staging

    NASA Astrophysics Data System (ADS)

    Cheirsilp, Ronnarit; Zang, Xiaonan; Bascom, Rebecca; Allen, Thomas W.; Mahraj, Rickhesvar P. M.; Higgins, William E.

    2016-03-01

    Positron emission tomography (PET) and X-ray computed tomography (CT) serve as major diagnostic imaging modalities in the lung-cancer staging process. Modern scanners provide co-registered whole-body PET/CT studies, collected while the patient breathes freely, and high-resolution chest CT scans, collected under a brief patient breath hold. Unfortunately, no method exists for registering a PET/CT study into the space of a high-resolution chest CT scan. If this could be done, vital diagnostic information offered by the PET/CT study could be brought seamlessly into the procedure plan used during live cancer-staging bronchoscopy. We propose a method for the deformable registration of whole-body PET/CT data into the space of a high-resolution chest CT study. We then demonstrate its potential for procedure planning and subsequent use in multimodal image-guided bronchoscopy.

  15. A new brain positron emission tomography scanner with semiconductor detectors for target volume delineation and radiotherapy treatment planning in patients with nasopharyngeal carcinoma.

    PubMed

    Katoh, Norio; Yasuda, Koichi; Shiga, Tohru; Hasegawa, Masakazu; Onimaru, Rikiya; Shimizu, Shinichi; Bengua, Gerard; Ishikawa, Masayori; Tamaki, Nagara; Shirato, Hiroki

    2012-03-15

    We compared two treatment planning methods for stereotactic boost for treating nasopharyngeal carcinoma (NPC): the use of conventional whole-body bismuth germanate (BGO) scintillator positron emission tomography (PET(CONV)WB) versus the new brain (BR) PET system using semiconductor detectors (PET(NEW)BR). Twelve patients with NPC were enrolled in this study. [(18)F]Fluorodeoxyglucose-PET images were acquired using both the PET(NEW)BR and the PET(CONV)WB system on the same day. Computed tomography (CT) and two PET data sets were transferred to a treatment planning system, and the PET(CONV)WB and PET(NEW)BR images were coregistered with the same set of CT images. Window width and level values for all PET images were fixed at 3000 and 300, respectively. The gross tumor volume (GTV) was visually delineated on PET images by using either PET(CONV)WB (GTV(CONV)) images or PET(NEW)BR (GTV(NEW)) images. Assuming a stereotactic radiotherapy boost of 7 ports, the prescribed dose delivered to 95% of the planning target volume (PTV) was set to 2000 cGy in 4 fractions. The average absolute volume (±standard deviation [SD]) of GTV(NEW) was 15.7 ml (±9.9) ml, and that of GTV(CONV) was 34.0 (±20.5) ml. The average GTV(NEW) was significantly smaller than that of GTV(CONV) (p = 0.0006). There was no statistically significant difference between the maximum dose (p = 0.0585) and the mean dose (p = 0.2748) of PTV. The radiotherapy treatment plan based on the new gross tumor volume (PLAN(NEW)) significantly reduced maximum doses to the cerebrum and cerebellum (p = 0.0418) and to brain stem (p = 0.0041). Results of the present study suggest that the new brain PET system using semiconductor detectors can provide more accurate tumor delineation than the conventional whole-body BGO PET system and may be an important tool for functional and molecular radiotherapy treatment planning. Copyright © 2012 Elsevier Inc. All rights reserved.

  16. Diagnostic value of FDG-PET/(CT) in children with fever of unknown origin and unexplained fever during immune suppression.

    PubMed

    Blokhuis, Gijsbert J; Bleeker-Rovers, Chantal P; Diender, Marije G; Oyen, Wim J G; Draaisma, Jos M Th; de Geus-Oei, Lioe-Fee

    2014-10-01

    Fever of unknown origin (FUO) and unexplained fever during immune suppression in children are challenging medical problems. The aim of this study is to investigate the diagnostic value of fluorine-18 fluorodeoxyglucose positron emission tomography (FDG-PET) and FDG-PET combined with computed tomography (FDG-PET/CT) in children with FUO and in children with unexplained fever during immune suppression. All FDG-PET/(CT) scans performed in the Radboud university medical center for the evaluation of FUO or unexplained fever during immune suppression in the last 10 years were reviewed. Results were compared with the final clinical diagnosis. FDG-PET/(CT) scans were performed in 31 children with FUO. A final diagnosis was established in 16 cases (52 %). Of the total number of scans, 32 % were clinically helpful. The sensitivity and specificity of FDG-PET/CT in these patients was 80 % and 78 %, respectively. FDG-PET/(CT) scans were performed in 12 children with unexplained fever during immune suppression. A final diagnosis was established in nine patients (75 %). Of the total number of these scans, 58 % were clinically helpful. The sensitivity and specificity of FDG-PET/CT in children with unexplained fever during immune suppression was 78 % and 67 %, respectively. FDG-PET/CT appears a valuable imaging technique in the evaluation of children with FUO and in the diagnostic process of children with unexplained fever during immune suppression. Prospective studies of FDG-PET/CT as part of a structured diagnostic protocol are warranted to assess the additional diagnostic value.

  17. Association between pet ownership and coronary artery disease in a Chinese population

    PubMed Central

    Xie, Zhi-Yong; Zhao, Di; Chen, Bing-Rui; Wang, You-Nan; Ma, Yao; Shi, Hao-Jie; Yang, Yang; Wang, Ze-Mu; Wang, Lian-Sheng

    2017-01-01

    Abstract A number of studies have suggested the benefits of pet ownership to human health, including cardiovascular disease (CVD). However, there are few findings regarding pet ownership and coronary artery disease (CAD). The objective of this study is to investigate the association between pet ownership and CAD in a Chinese population. From October 2015 to May 2016, a survey consisting of 561 consecutive patients was done in Nanjing, China. Based on the results of coronary arteriography for the first time, participants were divided into 2 groups (non-CAD and CAD groups). Pet ownership information was collected by using a questionnaire. After multivariate adjustments, pet ownership was associated with a decreased CAD risk (odds ratios [OR]: 0.504, 95% confidence intervals [CIs]: 0.310–0.819). There was a reduced CAD risk among dog owners (OR: 0.420, 95% CI: 0.242–0.728) when compared with the cat group (OR: 0.738, 95% CI: 0.240–2.266) and the cat and dog group (OR: 1.052, 95% CI: 0.330–3.355). With the increase of pet ownership duration, there was a decreased tendency of CAD risk, including years of keeping pets (P for trend = 0.008) and time of playing with pets per day (P for trend = 0.001). In addition, similar dose–response relationship was observed for starting age of keeping pets (P for trend = 0.002). Pet ownership, especially dog ownership, can be a protective factor for CAD in Chinese patients. PMID:28353582

  18. Highly adhesive and high fatigue-resistant copper/PET flexible electronic substrates

    NASA Astrophysics Data System (ADS)

    Park, Sang Jin; Ko, Tae-Jun; Yoon, Juil; Moon, Myoung-Woon; Oh, Kyu Hwan; Han, Jun Hyun

    2018-01-01

    A voidless Cu/PET substrate is fabricated by producing a superhydrophilic PET surface comprised of nanostructures with large width and height and then by Cu electroless plating. Effect of PET surface nanostructure size on the failure mechanism of the Cu/PET substrate is studied. The fabricated Cu/PET substrate exhibits a maximum peel strength of 1300 N m-1 without using an interlayer, and virtually no increase in electrical resistivity under the extreme cyclic bending condition of 1 mm curvature radius after 300 k cycles. The authors find that there is an optimum nanostructure size for the highest Cu/PET adhesion strength, and the failure mechanism of the Cu/PET flexible substrate depends on the PET surface nanostructure size. Thus, this work presents the possibility to produce flexible metal/polymer electronic substrates that have excellent interfacial adhesion between the metal and polymer and high fatigue resistance against repeated bending. Such metal/polymer substrates provides new design opportunities for wearable electronic devices that can withstand harsh environments and have extended lifetimes.

  19. Competitive Advantage of PET/MRI

    PubMed Central

    Jadvar, Hossein; Colletti, Patrick M.

    2013-01-01

    Multimodality imaging has made great strides in the imaging evaluation of patients with a variety of diseases. Positron emission tomography/computed tomography (PET/CT) is now established as the imaging modality of choice in many clinical conditions, particularly in oncology. While the initial development of combined PET/magnetic resonance imaging (PET/MRI) was in the preclinical arena, hybrid PET/MR scanners are now available for clinical use. PET/MRI combines the unique features of MRI including excellent soft tissue contrast, diffusion-weighted imaging, dynamic contrast-enhanced imaging, fMRI and other specialized sequences as well as MR spectroscopy with the quantitative physiologic information that is provided by PET. Most evidence for the potential clinical utility of PET/MRI is based on studies performed with side-by-side comparison or software-fused MRI and PET images. Data on distinctive utility of hybrid PET/MRI are rapidly emerging. There are potential competitive advantages of PET/MRI over PET/CT. In general, PET/MRI may be preferred over PET/CT where the unique features of MRI provide more robust imaging evaluation in certain clinical settings. The exact role and potential utility of simultaneous data acquisition in specific research and clinical settings will need to be defined. It may be that simultaneous PET/MRI will be best suited for clinical situations that are disease-specific, organ-specific, related to diseases of the children or in those patients undergoing repeated imaging for whom cumulative radiation dose must be kept as low as reasonably achievable. PET/MRI also offers interesting opportunities for use of dual modality probes. Upon clear definition of clinical utility, other important and practical issues related to business operational model, clinical workflow and reimbursement will also be resolved. PMID:23791129

  20. Competitive advantage of PET/MRI.

    PubMed

    Jadvar, Hossein; Colletti, Patrick M

    2014-01-01

    Multimodality imaging has made great strides in the imaging evaluation of patients with a variety of diseases. Positron emission tomography/computed tomography (PET/CT) is now established as the imaging modality of choice in many clinical conditions, particularly in oncology. While the initial development of combined PET/magnetic resonance imaging (PET/MRI) was in the preclinical arena, hybrid PET/MR scanners are now available for clinical use. PET/MRI combines the unique features of MRI including excellent soft tissue contrast, diffusion-weighted imaging, dynamic contrast-enhanced imaging, fMRI and other specialized sequences as well as MR spectroscopy with the quantitative physiologic information that is provided by PET. Most evidence for the potential clinical utility of PET/MRI is based on studies performed with side-by-side comparison or software-fused MRI and PET images. Data on distinctive utility of hybrid PET/MRI are rapidly emerging. There are potential competitive advantages of PET/MRI over PET/CT. In general, PET/MRI may be preferred over PET/CT where the unique features of MRI provide more robust imaging evaluation in certain clinical settings. The exact role and potential utility of simultaneous data acquisition in specific research and clinical settings will need to be defined. It may be that simultaneous PET/MRI will be best suited for clinical situations that are disease-specific, organ-specific, related to diseases of the children or in those patients undergoing repeated imaging for whom cumulative radiation dose must be kept as low as reasonably achievable. PET/MRI also offers interesting opportunities for use of dual modality probes. Upon clear definition of clinical utility, other important and practical issues related to business operational model, clinical workflow and reimbursement will also be resolved. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  1. Value of PET/CT 3D visualization of head and neck squamous cell carcinoma extended to mandible.

    PubMed

    Lopez, R; Gantet, P; Julian, A; Hitzel, A; Herbault-Barres, B; Alshehri, S; Payoux, P

    2018-05-01

    To study an original 3D visualization of head and neck squamous cell carcinoma extending to the mandible by using [18F]-NaF PET/CT and [18F]-FDG PET/CT imaging along with a new innovative FDG and NaF image analysis using dedicated software. The main interest of the 3D evaluation is to have a better visualization of bone extension in such cancers and that could also avoid unsatisfying surgical treatment later on. A prospective study was carried out from November 2016 to September 2017. Twenty patients with head and neck squamous cell carcinoma extending to the mandible (stage 4 in the UICC classification) underwent [18F]-NaF and [18F]-FDG PET/CT. We compared the delineation of 3D quantification obtained with [18F]-NaF and [18F]-FDG PET/CT. In order to carry out this comparison, a method of visualisation and quantification of PET images was developed. This new approach was based on a process of quantification of radioactive activity within the mandibular bone that objectively defined the significant limits of this activity on PET images and on a 3D visualization. Furthermore, the spatial limits obtained by analysis of the PET/CT 3D images were compared to those obtained by histopathological examination of mandibular resection which confirmed intraosseous extension to the mandible. The [18F]-NaF PET/CT imaging confirmed the mandibular extension in 85% of cases and was not shown in [18F]-FDG PET/CT imaging. The [18F]-NaF PET/CT was significantly more accurate than [18F]-FDG PET/CT in 3D assessment of intraosseous extension of head and neck squamous cell carcinoma. This new 3D information shows the importance in the imaging approach of cancers. All cases of mandibular extension suspected on [18F]-NaF PET/CT imaging were confirmed based on histopathological results as a reference. The [18F]-NaF PET/CT 3D visualization should be included in the pre-treatment workups of head and neck cancers. With the use of a dedicated software which enables objective delineation of radioactive activity within the bone, it gives a very encouraging results. The [18F]-FDG PET/CT appears insufficient to confirm mandibular extension. This new 3D simulation management is expected to avoid under treatment of patients with intraosseous mandibular extension of head and neck cancers. However, there is also a need for a further study that will compare the interest of PET/CT and PET/MRI in this indication. Copyright © 2018 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  2. Favorable versus unfavorable prognostic groups by post-chemoradiation FDG-PET imaging in node-positive esophageal squamous cell carcinoma patients treated with definitive chemoradiotherapy.

    PubMed

    Yap, Wing-Keen; Chang, Yu-Chuan; Hsieh, Chia-Hsun; Chao, Yin-Kai; Chen, Chien-Cheng; Shih, Ming-Chieh; Hung, Tsung-Min

    2018-05-01

    Our purpose was to examine the prognostic value of post-CRT PET based on the presence or absence of FDG-avid metastatic lymph node(s) and metabolic response of the primary tumor in patients with clinically node-positive ESCC treated with definitive chemoradiotherapy (dCRT). We identified 108 eligible patients treated by chemoradiotherapy (CRT) with or without resection from our prospectively collected database. Absence of FDG-avid metastatic lymph node with at least partial response of the primary tumor on PET scan after initial CRT was defined as the Post-CRT PET favorable group (yPET-F), and otherwise as unfavorable group (yPET-U). The Kaplan-Meier method and Cox regression were performed for survival analyses and multivariable analysis, respectively. The study cohort was comprised of 59 patients receiving dCRT. Forty-five patients receiving trimodality therapy (TMT) comprised the comparative group and four patients were excluded from further analyses for developing interval distant metastasis detected on post-CRT PET scan. The median follow-up for the study cohort was 41 months. On K-M analysis of the study cohort, yPET-F was found to have significantly better OS (2-year: 72.5% vs 13.7%, p < 0.01) and DMFS (2-year: 71.6% vs 36.6%, p = 0.01) than yPET-U. In multivariable analysis, yPET-F remained as a strong independent favorable prognosticator on both OS (HR 0.08, p < 0.01) and DMFS (HR 0.14, p = 0.02) for the dCRT cohort. Compared with TMT cohort, for yPET-U patients, TMT had better OS (p = 0.03) than dCRT-Operable and dCRT-Operable had superior OS (p = 0.04) than dCRT-Unresectable. For yPET-F patients, there was no difference in both OS (p > 0.99) and DMFS (p = 0.92) between these three groups. Absence of FDG-avid metastatic lymph node with at least partial response of the primary tumor on PET scan after CRT (i.e., yPET-F status) prognosticate for excellent OS and DMFS in cN+ ESCC patients treated with dCRT, and might be comparable to TMT.

  3. [The status of domestic PET/CT attendance in the light of the waiting list data].

    PubMed

    Galuska, László; Balkay, László

    2010-06-01

    The aim of the study is to demonstrate the diagnostic and geographical distribution of the domestic PET/CT examinations financed by the OEP based on the data from the waiting list of the past 4 years. The analysis of the demonstrated data can support the rational usage of PET/CT examination contingents in the domestic oncological attendance, which has growing importance. PET examinations with oncological aims have started in Debrecen more than 10 years ago. In 2005 already 1500 PET examinations have been carried out. According to the governmental regulation accepted in 2006, OEP ensures the financing of the three PET/CT centers until 2012, which means 12,000 examinations in 2012. However, the number of domestic oncological patients requiring PET/CT examinations can reach the number of 20,000-30,000 patients. The study summarizes the number of patients who applied for PET/CT examinations for the first time and later again between 2006 and 2010, based on the data of the waiting list, and the change of the patient assigning diagnosis and the number of examinations carried out with 18F-FDG and with 11C-methionine. The study demonstrates the number of examinations by counties which characterize the population's access to PET/CT. The assigning diagnosis in 2007 was already widespread and focused on problems. After the regulation came in to force in 2008 the possibilities significantly decreased. Clinical cases which were efficiently examined with PET/CT earlier were left out from the indication list. The distribution by county is uneven, although the number of examinations increases year by year. The number of repeated examinations increases as well. As a conclusion, the annual PET/CT examination contingents are constantly exploited. This might seem sufficient, because the method has not become a part of the oncological routine in all counties. Although the current indication list includes the most frequent oncological cases requiring PET/CT, the abandoning of the less frequent ones narrowed the professional latitude, which is disadvantageous for the patients suffering from such diseases. The radiopharmacon supply of PET/CT centers is inadequate thus they cannot provide modern oncological diagnostic attendance in case of frequent types of cancer (such as prostate). In the long run the growing number of repeated PET/CT examinations built in the oncological professional protocol has to be taken into account.

  4. Exposure to household furry pets influences the gut microbiota of infant at 3-4 months following various birth scenarios.

    PubMed

    Tun, Hein M; Konya, Theodore; Takaro, Tim K; Brook, Jeffrey R; Chari, Radha; Field, Catherine J; Guttman, David S; Becker, Allan B; Mandhane, Piush J; Turvey, Stuart E; Subbarao, Padmaja; Sears, Malcolm R; Scott, James A; Kozyrskyj, Anita L

    2017-04-06

    Early-life exposure to household pets has the capacity to reduce risk for overweight and allergic disease, especially following caesarean delivery. Since there is some evidence that pets also alter the gut microbial composition of infants, changes to the gut microbiome are putative pathways by which pet exposure can reduce these risks to health. To investigate the impact of pre- and postnatal pet exposure on infant gut microbiota following various birth scenarios, this study employed a large subsample of 746 infants from the Canadian Healthy Infant Longitudinal Development Study (CHILD) cohort, whose mothers were enrolled during pregnancy between 2009 and 2012. Participating mothers were asked to report on household pet ownership at recruitment during the second or third trimester and 3 months postpartum. Infant gut microbiota were profiled with 16S rRNA sequencing from faecal samples collected at the mean age of 3.3 months. Two categories of pet exposure (i) only during pregnancy and (ii) pre- and postnatally were compared to no pet exposure under different birth scenarios. Over half of studied infants were exposed to at least one furry pet in the prenatal and/or postnatal periods, of which 8% were exposed in pregnancy alone and 46.8% had exposure during both time periods. As a common effect in all birth scenarios, pre- and postnatal pet exposure enriched the abundance of Oscillospira and/or Ruminococcus (P < 0.05) with more than a twofold greater likelihood of high abundance. Among vaginally born infants with maternal intrapartum antibiotic prophylaxis exposure, Streptococcaceae were substantially and significantly reduced by pet exposure (P < 0.001, FDRp = 0.03), reflecting an 80% decreased likelihood of high abundance (OR 0.20, 95%CI, 0.06-0.70) for pet exposure during pregnancy alone and a 69% reduced likelihood (OR 0.31, 95%CI, 0.16-0.58) for exposure in the pre- and postnatal time periods. All of these associations were independent of maternal asthma/allergy status, siblingship, breastfeeding exclusivity and other home characteristics. The impact of pet ownership varies under different birth scenarios; however, in common, exposure to pets increased the abundance of two bacteria, Ruminococcus and Oscillospira, which have been negatively associated with childhood atopy and obesity.

  5. The diagnostic performance and added value of (18)F-FDG PET/CT in the detection of liver metastases in recurrent colorectal carcinoma patients.

    PubMed

    Odalovic, Strahinja; Artiko, Vera; Sobic-Saranovic, Dragana; Stojiljkovic, Milica; Petrovic, Milorad; Petrovic, Nebojsa; Kozarevic, Nebojsa; Grozdic-Milojevic, Isidora; Obradovic, Vladimir

    2015-01-01

    The aim of this study was to assess the value of (18)F-fluorodeoxyglucose ((18)F-FDG) PET/CT in detection of liver metastases in patients with suspected recurrent colorectal carcinoma, as well as to compare diagnostic performance of (18)F-FDG PET/CT with conventional imaging methods (MDCT). This study included 73 patients with resected primary colorectal adenocarcinoma referred for (18)F-FDG PET/CT to the National PET Center, at the Clinical Center of Serbia, Belgrade, from January 2010 to May 2013, with suspicion of recurrence. The patients underwent (18)F-FDG PET/CT examination on a 64-slice hybrid PET/CT scanner (Biograph, TruePoint64, Siemens Medical Solutions, Inc. USA). Prior to (18)F-FDG PET/CT all patients underwent contrast-enhanced MDCT. Findings of (18)F-FDG PET/CT and MDCT were compared to findings of subsequent histopathological examinations or with results of clinical and imaging follow-up over at least six months. Final diagnosis of liver metastases of colorectal cancer was made either by histopathological examination of specimen after biopsy or surgery, or based on clinical, laboratory and imaging evaluation during first six months after PET/CT scan. In detection of liver metastases (18)F-FDG PET/CT showed sensitivity, specificity, positive predictive value, negative predictive value and accuracy of 83.3%, 95.3%, 92.6%, 89.1% and 90.4%, respectively. In addition, MDCT showed sensitivity, specificity, positive predictive value, negative predictive value and accuracy in detection of liver metastases of 60%, 88.4%, 78.3%, 76% and 76.7%, respectively. There was significant difference in sensitivity (83.3% vs 60%; P=0.045) between these two methods. In addition, significant difference was observed in accuracy between PET/CT and MDCT (90.4% vs 76.7%; P=0.016). The higher specificity in visualization of liver metastases was also achieved by (18)F-FDG PET/CT compared to MDCT (95.3% vs 88.4%), but this difference was not significant (P=0.37). (18)F-FDG PET/CT was highly sensitive, specific and accurate method in detection of liver metastases in patients with suspected recurrent colorectal carcinoma in our study. This hybrid imaging showed superior diagnostic performance in evaluation of suspected colorectal cancer liver metastases compared to conventional imaging.

  6. "My pet has passed": Relations of adult attachment styles and current feelings of grief and trauma after the event.

    PubMed

    Brown, Olivia K; Symons, Douglas K

    2016-01-01

    This study examined attachment relationships and emotional distress after the passing of a pet. Participants were 73 university students 17-26 years of age who had lost a family pet within the past 5 years. They completed measures of attachment styles toward people and their pet, as well as complicated grief, depression, and trauma. As hypothesized, there were positive relations between attachments with people and pets, and anxiety in pet attachment was positively related to complicated grief, even when attachment with people was controlled. Results are discussed in terms of the importance of attachment style to grief over loss.

  7. PET-PANC: multicentre prospective diagnostic accuracy and health economic analysis study of the impact of combined modality 18fluorine-2-fluoro-2-deoxy-d-glucose positron emission tomography with computed tomography scanning in the diagnosis and management of pancreatic cancer.

    PubMed

    Ghaneh, Paula; Hanson, Robert; Titman, Andrew; Lancaster, Gill; Plumpton, Catrin; Lloyd-Williams, Huw; Yeo, Seow Tien; Edwards, Rhiannon Tudor; Johnson, Colin; Abu Hilal, Mohammed; Higginson, Antony P; Armstrong, Tom; Smith, Andrew; Scarsbrook, Andrew; McKay, Colin; Carter, Ross; Sutcliffe, Robert P; Bramhall, Simon; Kocher, Hemant M; Cunningham, David; Pereira, Stephen P; Davidson, Brian; Chang, David; Khan, Saboor; Zealley, Ian; Sarker, Debashis; Al Sarireh, Bilal; Charnley, Richard; Lobo, Dileep; Nicolson, Marianne; Halloran, Christopher; Raraty, Michael; Sutton, Robert; Vinjamuri, Sobhan; Evans, Jonathan; Campbell, Fiona; Deeks, Jon; Sanghera, Bal; Wong, Wai-Lup; Neoptolemos, John P

    2018-02-01

    Pancreatic cancer diagnosis and staging can be difficult in 10-20% of patients. Positron emission tomography (PET)/computed tomography (CT) adds precise anatomical localisation to functional data. The use of PET/CT may add further value to the diagnosis and staging of pancreatic cancer. To determine the incremental diagnostic accuracy and impact of PET/CT in addition to standard diagnostic work-up in patients with suspected pancreatic cancer. A multicentre prospective diagnostic accuracy and clinical value study of PET/CT in suspected pancreatic malignancy. Patients with suspected pancreatic malignancy. All patients to undergo PET/CT following standard diagnostic work-up. The primary outcome was the incremental diagnostic value of PET/CT in addition to standard diagnostic work-up with multidetector computed tomography (MDCT). Secondary outcomes were (1) changes in patients' diagnosis, staging and management as a result of PET/CT; (2) changes in the costs and effectiveness of patient management as a result of PET/CT; (3) the incremental diagnostic value of PET/CT in chronic pancreatitis; (4) the identification of groups of patients who would benefit most from PET/CT; and (5) the incremental diagnostic value of PET/CT in other pancreatic tumours. Between 2011 and 2013, 589 patients with suspected pancreatic cancer underwent MDCT and PET/CT, with 550 patients having complete data and in-range PET/CT. Sensitivity and specificity for the diagnosis of pancreatic cancer were 88.5% and 70.6%, respectively, for MDCT and 92.7% and 75.8%, respectively, for PET/CT. The maximum standardised uptake value (SUV max. ) for a pancreatic cancer diagnosis was 7.5. PET/CT demonstrated a significant improvement in relative sensitivity ( p  = 0.01) and specificity ( p  = 0.023) compared with MDCT. Incremental likelihood ratios demonstrated that PET/CT significantly improved diagnostic accuracy in all scenarios ( p  < 0.0002). PET/CT correctly changed the staging of pancreatic cancer in 56 patients ( p  = 0.001). PET/CT influenced management in 250 (45%) patients. PET/CT stopped resection in 58 (20%) patients who were due to have surgery. The benefit of PET/CT was limited in patients with chronic pancreatitis or other pancreatic tumours. PET/CT was associated with a gain in quality-adjusted life-years of 0.0157 (95% confidence interval -0.0101 to 0.0430). In the base-case model PET/CT was seen to dominate MDCT alone and is thus highly likely to be cost-effective for the UK NHS. PET/CT was seen to be most cost-effective for the subgroup of patients with suspected pancreatic cancer who were thought to be resectable. PET/CT provided a significant incremental diagnostic benefit in the diagnosis of pancreatic cancer and significantly influenced the staging and management of patients. PET/CT had limited utility in chronic pancreatitis and other pancreatic tumours. PET/CT is likely to be cost-effective at current reimbursement rates for PET/CT to the UK NHS. This was not a randomised controlled trial and therefore we do not have any information from patients who would have undergone MDCT only for comparison. In addition, there were issues in estimating costs for PET/CT. Future work should evaluate the role of PET/CT in intraductal papillary mucinous neoplasm and prognosis and response to therapy in patients with pancreatic cancer. Current Controlled Trials ISRCTN73852054 and UKCRN 8166. The National Institute for Health Research Health Technology Assessment programme.

  8. Myocardial perfusion imaging with PET

    PubMed Central

    Nakazato, Ryo; Berman, Daniel S; Alexanderson, Erick; Slomka, Piotr

    2013-01-01

    PET-myocardial perfusion imaging (MPI) allows accurate measurement of myocardial perfusion, absolute myocardial blood flow and function at stress and rest in a single study session performed in approximately 30 min. Various PET tracers are available for MPI, and rubidium-82 or nitrogen-13-ammonia is most commonly used. In addition, a new fluorine-18-based PET-MPI tracer is currently being evaluated. Relative quantification of PET perfusion images shows very high diagnostic accuracy for detection of obstructive coronary artery disease. Dynamic myocardial blood flow analysis has demonstrated additional prognostic value beyond relative perfusion imaging. Patient radiation dose can be reduced and image quality can be improved with latest advances in PET/CT equipment. Simultaneous assessment of both anatomy and perfusion by hybrid PET/CT can result in improved diagnostic accuracy. Compared with SPECT-MPI, PET-MPI provides higher diagnostic accuracy, using lower radiation doses during a shorter examination time period for the detection of coronary artery disease. PMID:23671459

  9. Role of attachment in response to pet loss.

    PubMed

    Field, Nigel P; Orsini, Lisa; Gavish, Roni; Packman, Wendy

    2009-04-01

    This study examined the impact of attachment on grief severity following the death of a pet. Seventy-one participants who had lost a dog or cat within the past year completed a set of measures that included an attachment measure assessing individual differences in attachment anxiety and avoidance, strength of the past attachment to the pet, the continuing bond with the deceased pet, social support, and complicated grief symptoms. Attachment anxiety and strength of the past attachment to the pet were each uniquely predictive of more severe grief. Furthermore, the continuing bond to the deceased pet partially mediated the impact of strength of the past attachment to the pet on grief severity. No significant mediators of the effect of attachment anxiety on grief were found, however. The results highlight the importance of distinguishing strength of attachment from attachment security in examining the effect of attachment on response to pet loss.

  10. Interaction of proflavin with aromatic amines in homogeneous and micellar media: Photoinduced electron transfer probed by magnetic field effect

    NASA Astrophysics Data System (ADS)

    Chakraborty, Brotati; Basu, Samita

    2010-02-01

    Photoinduced electron transfer (PET) between proflavin (PF +) and two aromatic amines viz., dimethylaniline (DMA) and 4,4'-bis(dimethylamino)diphenylmethane (DMDPM) is studied in homogeneous and heterogeneous media using steady-state as well as time-resolved fluorescence spectroscopy and laser flash photolysis with an associated magnetic field. Ionic micelles have been used to study the effect of charge of proflavin on PET with amines. Magnetic field effect on PET reactions reveals that the parent spin-state of precursors of PET for DMA-PF + system is singlet while for DMDPM-PF + system is triplet, implying that the dynamics of PET is influenced by the structure of the donor.

  11. Molecular Imaging and Precision Medicine: PET/Computed Tomography and Therapy Response Assessment in Oncology.

    PubMed

    Sheikhbahaei, Sara; Mena, Esther; Pattanayak, Puskar; Taghipour, Mehdi; Solnes, Lilja B; Subramaniam, Rathan M

    2017-01-01

    A variety of methods have been developed to assess tumor response to therapy. Standardized qualitative criteria based on 18F-fluoro-deoxyglucose PET/computed tomography have been proposed to evaluate the treatment effectiveness in specific cancers and these allow more accurate therapy response assessment and survival prognostication. Multiple studies have addressed the utility of the volumetric PET biomarkers as prognostic indicators but there is no consensus about the preferred segmentation methodology for these metrics. Heterogeneous intratumoral uptake was proposed as a novel PET metric for therapy response assessment. PET imaging techniques will be used to study the biological behavior of cancers during therapy. Copyright © 2016 Elsevier Inc. All rights reserved.

  12. The usefulness of (18)F-FDG PET/MRI fusion image in diagnosing pancreatic tumor: comparison with (18)F-FDG PET/CT.

    PubMed

    Nagamachi, Shigeki; Nishii, Ryuichi; Wakamatsu, Hideyuki; Mizutani, Youichi; Kiyohara, Shogo; Fujita, Seigo; Futami, Shigemi; Sakae, Tatefumi; Furukoji, Eiji; Tamura, Shozo; Arita, Hideo; Chijiiwa, Kazuo; Kawai, Keiichi

    2013-07-01

    This study aimed at demonstrating the feasibility of retrospectively fused (18)F FDG-PET and MRI (PET/MRI fusion image) in diagnosing pancreatic tumor, in particular differentiating malignant tumor from benign lesions. In addition, we evaluated additional findings characterizing pancreatic lesions by FDG-PET/MRI fusion image. We analyzed retrospectively 119 patients: 96 cancers and 23 benign lesions. FDG-PET/MRI fusion images (PET/T1 WI or PET/T2WI) were made by dedicated software using 1.5 Tesla (T) MRI image and FDG-PET images. These images were interpreted by two well-trained radiologists without knowledge of clinical information and compared with FDG-PET/CT images. We compared the differential diagnostic capability between PET/CT and FDG-PET/MRI fusion image. In addition, we evaluated additional findings such as tumor structure and tumor invasion. FDG-PET/MRI fusion image significantly improved accuracy compared with that of PET/CT (96.6 vs. 86.6 %). As additional finding, dilatation of main pancreatic duct was noted in 65.9 % of solid types and in 22.6 % of cystic types, on PET/MRI-T2 fusion image. Similarly, encasement of adjacent vessels was noted in 43.1 % of solid types and in 6.5 % of cystic types. Particularly in cystic types, intra-tumor structures such as mural nodule (35.4 %) or intra-cystic septum (74.2 %) were detected additionally. Besides, PET/MRI-T2 fusion image could detect extra benign cystic lesions (9.1 % in solid type and 9.7 % in cystic type) that were not noted by PET/CT. In diagnosing pancreatic lesions, FDG-PET/MRI fusion image was useful in differentiating pancreatic cancer from benign lesions. Furthermore, it was helpful in evaluating relationship between lesions and surrounding tissues as well as in detecting extra benign cysts.

  13. 18F-choline PET/MRI in suspected recurrence of prostate carcinoma.

    PubMed

    Riola-Parada, C; Carreras-Delgado, J L; Pérez-Dueñas, V; Garcerant-Tafur, M; García-Cañamaque, L

    2018-05-21

    To evaluate the usefulness of simultaneous 18 F-choline PET/MRI in the suspicion of prostate cancer recurrence and to relate 18 F-choline PET/MRI detection rate with analytical and pathological variables. 27 patients with prostate cancer who received local therapy as primary treatment underwent a 18 F-choline PET/MRI due to suspicion of recurrence (persistently rising serum PSA level). 18 F-choline PET/MRI findings were validated by anatomopathological analysis, other imaging tests or by biochemical response to oncological treatment. 18 F-choline PET/MRI detected disease in 15 of 27 patients (detection rate 55.56%). 4 (15%) presented exclusively local recurrence, 5 (18%) lymph node metastases and 7 (26%) bone metastases. Mean PSA (PSA med ) at study time was 2.94ng/mL (range 0.18-10ng/mL). PSA med in patients with positive PET/MRI was 3.70ng/mL (range 0.24-10ng/mL), higher than in patients with negative PET/MRI, PSA med 1.97ng/mL (range 0.18-4.38ng/mL), although without statistically significant differences. Gleason score at diagnosis in patients with a positive study was 7.33 (range 6-9) and in patients with a negative study was 7 (range 6-9), without statistically significant differences. 18 F-choline PET/MRI detection rate was considerable despite the relatively low PSA values in our sample. The influence of Gleason score and PSA level on 18 F-choline PET/MRI detection rate was not statistically significant. Copyright © 2018 Sociedad Española de Medicina Nuclear e Imagen Molecular. Publicado por Elsevier España, S.L.U. All rights reserved.

  14. A meta-analysis of the literature for whole-body FDG PET detection of recurrent colorectal cancer.

    PubMed

    Huebner, R H; Park, K C; Shepherd, J E; Schwimmer, J; Czernin, J; Phelps, M E; Gambhir, S S

    2000-07-01

    A meta-analysis of the literature for the use of FDG PET in the detection of recurrent colorectal cancer (CRC) was conducted to evaluate the quality of the reported studies. Overall values for the sensitivity and specificity of whole-body FDG PET and an overall FDG PET-directed percentage change in management were also determined through this analysis. Guidelines to evaluate the articles were formulated on the basis of the U.S. medical payer source criteria for assessing studies that report information on usage of new medical technology. A metaanalysis was conducted using methodology described in the peer-reviewed literature. On the basis of the guidelines established for our review, the availability of necessary information for assessing the reliability of the FDG PET data for diagnosing recurrent CRC was less than ideal. Through a meta-analysis of 11 articles, we determined, within a 95% confidence level, an overall sensitivity of 97% (95% confidence level, 95%-99%) and an overall specificity of 76% (95% confidence level, 64%-88%) for FDG PET detecting recurrent CRC throughout the whole body. Furthermore, through pooling of the change-in-management data, an overall FDG PET-directed change in management was calculated to be 29% (95% confidence level, 25%-34%). Our review suggests that improvements can be made to more effectively report the results of these FDG PET studies. The overall values determined through the meta-analysis indicate the potential benefits of using FDG PET as a diagnostic or management tool. Furthermore, these values should prove to be useful to assess the cost-effectiveness of using FDG PET in the management of patients with recurrent CRC.

  15. The Role of Chemistry in Positron Emission Tomography.

    ERIC Educational Resources Information Center

    Feliu, Anthony L.

    1988-01-01

    Investigates use of positron emission tomography (PET) to study in-vivo metabolic processes. Discusses methodology of PET and medical uses. Outlines the production of different radioisotopes used in PET radiotracers. Includes selected bibliography. (ML)

  16. Cell therapy attempted as a novel approach for chronic traumatic brain injury - a pilot study.

    PubMed

    Sharma, Alok; Sane, Hemangi; Kulkarni, Pooja; Yadav, Jayanti; Gokulchandran, Nandini; Biju, Hema; Badhe, Prerna

    2015-01-01

    Traumatic brain injury is an injury to the brain parenchyma resulting from external factors such as vehicular accidents, falls, or sports injuries. Its outcome involves primary insult followed by a cascade of secondary insult, resulting in diffuse axonal injury further causing white matter damage. Surgical intervention targets the primary damage, whereas only few treatment alternatives are available to treat the secondary damage. Cellular therapy could be one of the prospective therapeutic options, as it has the potential to arrest the degeneration and promote regeneration of new cells in the brain. We conducted a pilot study on 14 cases who were administered with autologous bone marrow mononuclear cells, intrathecally. The follow up was done at 1 week, 3 months and 6 months after the intervention. The Functional Independence Measure scale, the SF-8 Health Survey Scoring and the disability rating scale were used as outcome measures. These scales showed a positive shift in scores at the end of 6 months. Improvements were observed in various symptoms, along with activities of daily living. Improvement in PET CT scan performed before and 6 months after the intervention in 3 patients corresponded to the clinical and functional improvements observed in these patients. The results of this study suggest that cell therapy may promote functional recovery leading to an improved quality of life in chronic TBI. Although the results are positive, the improvements after cell therapy are not optimal. Hence, additional multicenter, controlled studies are required to establish cell therapy as a standard therapeutic approach.

  17. Pet Ownership may Attenuate Loneliness Among Older Adult Primary Care Patients Who Live Alone

    PubMed Central

    Stanley, Ian H.; Conwell, Yeates; Bowen, Connie; Van Orden, Kimberly A.

    2013-01-01

    Objectives Older adults who report feelings of loneliness are at increased risk for a range of negative physical and mental health outcomes, including early mortality. Identifying potential sources of social connectedness, such as pet ownership, could add to the understanding of how to promote health and well-being in older adults. The aim of this study is to describe the association of pet ownership and loneliness. Methods The current study utilizes cross-sectional survey data from a sample (N = 830) of older adult primary care patients (age > 60 years). Results Pet owners were 36% less likely than non-pet owners to report loneliness, in a model controlling for age, living status (i.e., alone vs. not alone), happy mood, and seasonal residency (adjOR = 0.64, 95% CI = 0.41-0.98, p <.05). An interaction was found between pet ownership and living status (b = −1.60, p < .001) in which living alone and not owning a pet was associated with the greatest odds of reporting feelings of loneliness. Conclusions Findings suggest that pet ownership may confer benefits for well-being, including attenuating feelings of loneliness and its related sequelae, among older adults who live alone. PMID:24047314

  18. In vivo PET imaging of neuroinflammation in Alzheimer's disease.

    PubMed

    Lagarde, Julien; Sarazin, Marie; Bottlaender, Michel

    2018-05-01

    Increasing evidence suggests that neuroinflammation contributes to the pathophysiology of many neurodegenerative diseases, especially Alzheimer's disease (AD). Molecular imaging by PET may be a useful tool to assess neuroinflammation in vivo, thus helping to decipher the complex role of inflammatory processes in the pathophysiology of neurodegenerative diseases and providing a potential means of monitoring the effect of new therapeutic approaches. For this objective, the main target of PET studies is the 18 kDa translocator protein (TSPO), as it is overexpressed by activated microglia. In the present review, we describe the most widely used PET tracers targeting the TSPO, the methodological issues in tracer quantification and summarize the results obtained by TSPO PET imaging in AD, as well as in neurodegenerative disorders associated with AD, in psychiatric disorders and ageing. We also briefly describe alternative PET targets and imaging modalities to study neuroinflammation. Lastly, we question the meaning of PET imaging data in the context of a highly complex and multifaceted role of neuroinflammation in neurodegenerative diseases. This overview leads to the conclusion that PET imaging of neuroinflammation is a promising way of deciphering the enigma of the pathophysiology of AD and of monitoring the effect of new therapies.

  19. Pet ownership may attenuate loneliness among older adult primary care patients who live alone.

    PubMed

    Stanley, Ian H; Conwell, Yeates; Bowen, Connie; Van Orden, Kimberly A

    2014-01-01

    Older adults who report feelings of loneliness are at increased risk for a range of negative physical and mental health outcomes, including early mortality. Identifying potential sources of social connectedness, such as pet ownership, could add to the understanding of how to promote health and well-being in older adults. The aim of this study is to describe the association of pet ownership and loneliness. The current study utilizes cross-sectional survey data from a sample (N = 830) of older adult primary care patients (age ≥ 60 years). Pet owners were 36% less likely than non-pet owners to report loneliness, in a model controlling for age, living status (i.e., alone vs. not alone), happy mood, and seasonal residency (adjOR = 0.64, 95% CI = 0.41-0.98, p < 0.05). An interaction was found between pet ownership and living status (b = -1.60, p < 0.001) in which living alone and not owning a pet was associated with the greatest odds of reporting feelings of loneliness. The findings suggest that pet ownership may confer benefits for well-being, including attenuating feelings of loneliness and its related sequelae, among older adults who live alone.

  20. NEMA NU 2-2012 performance studies for the SiPM-based ToF-PET component of the GE SIGNA PET/MR system.

    PubMed

    Grant, Alexander M; Deller, Timothy W; Khalighi, Mohammad Mehdi; Maramraju, Sri Harsha; Delso, Gaspar; Levin, Craig S

    2016-05-01

    The GE SIGNA PET/MR is a new whole body integrated time-of-flight (ToF)-PET/MR scanner from GE Healthcare. The system is capable of simultaneous PET and MR image acquisition with sub-400 ps coincidence time resolution. Simultaneous PET/MR holds great potential as a method of interrogating molecular, functional, and anatomical parameters in clinical disease in one study. Despite the complementary imaging capabilities of PET and MRI, their respective hardware tends to be incompatible due to mutual interference. In this work, the GE SIGNA PET/MR is evaluated in terms of PET performance and the potential effects of interference from MRI operation. The NEMA NU 2-2012 protocol was followed to measure PET performance parameters including spatial resolution, noise equivalent count rate, sensitivity, accuracy, and image quality. Each of these tests was performed both with the MR subsystem idle and with continuous MR pulsing for the duration of the PET data acquisition. Most measurements were repeated at three separate test sites where the system is installed. The scanner has achieved an average of 4.4, 4.1, and 5.3 mm full width at half maximum radial, tangential, and axial spatial resolutions, respectively, at 1 cm from the transaxial FOV center. The peak noise equivalent count rate (NECR) of 218 kcps and a scatter fraction of 43.6% are reached at an activity concentration of 17.8 kBq/ml. Sensitivity at the center position is 23.3 cps/kBq. The maximum relative slice count rate error below peak NECR was 3.3%, and the residual error from attenuation and scatter corrections was 3.6%. Continuous MR pulsing had either no effect or a minor effect on each measurement. Performance measurements of the ToF-PET whole body GE SIGNA PET/MR system indicate that it is a promising new simultaneous imaging platform.

  1. Clinical evaluation of 4D PET motion compensation strategies for treatment verification in ion beam therapy

    NASA Astrophysics Data System (ADS)

    Gianoli, Chiara; Kurz, Christopher; Riboldi, Marco; Bauer, Julia; Fontana, Giulia; Baroni, Guido; Debus, Jürgen; Parodi, Katia

    2016-06-01

    A clinical trial named PROMETHEUS is currently ongoing for inoperable hepatocellular carcinoma (HCC) at the Heidelberg Ion Beam Therapy Center (HIT, Germany). In this framework, 4D PET-CT datasets are acquired shortly after the therapeutic treatment to compare the irradiation induced PET image with a Monte Carlo PET prediction resulting from the simulation of treatment delivery. The extremely low count statistics of this measured PET image represents a major limitation of this technique, especially in presence of target motion. The purpose of the study is to investigate two different 4D PET motion compensation strategies towards the recovery of the whole count statistics for improved image quality of the 4D PET-CT datasets for PET-based treatment verification. The well-known 4D-MLEM reconstruction algorithm, embedding the motion compensation in the reconstruction process of 4D PET sinograms, was compared to a recently proposed pre-reconstruction motion compensation strategy, which operates in sinogram domain by applying the motion compensation to the 4D PET sinograms. With reference to phantom and patient datasets, advantages and drawbacks of the two 4D PET motion compensation strategies were identified. The 4D-MLEM algorithm was strongly affected by inverse inconsistency of the motion model but demonstrated the capability to mitigate the noise-break-up effects. Conversely, the pre-reconstruction warping showed less sensitivity to inverse inconsistency but also more noise in the reconstructed images. The comparison was performed by relying on quantification of PET activity and ion range difference, typically yielding similar results. The study demonstrated that treatment verification of moving targets could be accomplished by relying on the whole count statistics image quality, as obtained from the application of 4D PET motion compensation strategies. In particular, the pre-reconstruction warping was shown to represent a promising choice when combined with intra-reconstruction smoothing.

  2. A perspective on the future role of brain pet imaging in exercise science.

    PubMed

    Boecker, Henning; Drzezga, Alexander

    2016-05-01

    Positron Emission Tomography (PET) bears a unique potential for examining the effects of physical exercise (acute or chronic) within the central nervous system in vivo, including cerebral metabolism, neuroreceptor occupancy, and neurotransmission. However, application of Neuro-PET in human exercise science is as yet surprisingly sparse. To date the field has been dominated by non-invasive neuroelectrical techniques (EEG, MEG) and structural/functional magnetic resonance imaging (sMRI/fMRI). Despite PET having certain inherent disadvantages, in particular radiation exposure and high costs limiting applicability at large scale, certain research questions in human exercise science can exclusively be addressed with PET: The "metabolic trapping" properties of (18)F-FDG PET as the most commonly used PET-tracer allow examining the neuronal mechanisms underlying various forms of acute exercise in a rather unconstrained manner, i.e. under realistic training scenarios outside the scanner environment. Beyond acute effects, (18)F-FDG PET measurements under resting conditions have a strong prospective for unraveling the influence of regular physical activity on neuronal integrity and potentially neuroprotective mechanisms in vivo, which is of special interest for aging and dementia research. Quantification of cerebral glucose metabolism may allow determining the metabolic effects of exercise interventions in the entire human brain and relating the regional cerebral rate of glucose metabolism (rCMRglc) with behavioral, neuropsychological, and physiological measures. Apart from FDG-PET, particularly interesting applications comprise PET ligand studies that focus on dopaminergic and opioidergic neurotransmission, both key transmitter systems for exercise-related psychophysiological effects, including mood changes, reward processing, antinociception, and in its most extreme form 'exercise dependence'. PET ligand displacement approaches even allow quantifying specific endogenous neurotransmitter release under acute exercise interventions, to which modern PET/MR hybrid technology will be additionally fruitful. Experimental studies exploiting the unprecedented multimodal imaging capacities of PET/MR in human exercise sciences are as yet pending. Copyright © 2015 Elsevier Inc. All rights reserved.

  3. Quantitative Evaluation of Atlas-based Attenuation Correction for Brain PET in an Integrated Time-of-Flight PET/MR Imaging System.

    PubMed

    Yang, Jaewon; Jian, Yiqiang; Jenkins, Nathaniel; Behr, Spencer C; Hope, Thomas A; Larson, Peder E Z; Vigneron, Daniel; Seo, Youngho

    2017-07-01

    Purpose To assess the patient-dependent accuracy of atlas-based attenuation correction (ATAC) for brain positron emission tomography (PET) in an integrated time-of-flight (TOF) PET/magnetic resonance (MR) imaging system. Materials and Methods Thirty recruited patients provided informed consent in this institutional review board-approved study. All patients underwent whole-body fluorodeoxyglucose PET/computed tomography (CT) followed by TOF PET/MR imaging. With use of TOF PET data, PET images were reconstructed with four different attenuation correction (AC) methods: PET with patient CT-based AC (CTAC), PET with ATAC (air and bone from an atlas), PET with ATAC patientBone (air and tissue from the atlas with patient bone), and PET with ATAC boneless (air and tissue from the atlas without bone). For quantitative evaluation, PET mean activity concentration values were measured in 14 1-mL volumes of interest (VOIs) distributed throughout the brain and statistical significance was tested with a paired t test. Results The mean overall difference (±standard deviation) of PET with ATAC compared with PET with CTAC was -0.69 kBq/mL ± 0.60 (-4.0% ± 3.2) (P < .001). The results were patient dependent (range, -9.3% to 0.57%) and VOI dependent (range, -5.9 to -2.2). In addition, when bone was not included for AC, the overall difference of PET with ATAC boneless (-9.4% ± 3.7) was significantly worse than that of PET with ATAC (-4.0% ± 3.2) (P < .001). Finally, when patient bone was used for AC instead of atlas bone, the overall difference of PET with ATAC patientBone (-1.5% ± 1.5) improved over that of PET with ATAC (-4.0% ± 3.2) (P < .001). Conclusion ATAC in PET/MR imaging achieves similar quantification accuracy to that from CTAC by means of atlas-based bone compensation. However, patient-specific anatomic differences from the atlas causes bone attenuation differences and misclassified sinuses, which result in patient-dependent performance variation of ATAC. © RSNA, 2017 Online supplemental material is available for this article.

  4. Pet Ownership and Cancer Risk in the Women's Health Initiative.

    PubMed

    Garcia, David O; Lander, Eric M; Wertheim, Betsy C; Manson, JoAnn E; Volpe, Stella L; Chlebowski, Rowan T; Stefanick, Marcia L; Lessin, Lawrence S; Kuller, Lewis H; Thomson, Cynthia A

    2016-09-01

    Pet ownership and cancer are both highly prevalent in the United States. Evidence suggests that associations may exist between this potentially modifiable factor and cancer prevention, though studies are sparse. The present report examined whether pet ownership (dog, cat, or bird) is associated with lower risk for total cancer and site-specific obesity-related cancers. This was a prospective analysis of 123,560 participants (20,981 dog owners; 19,288 cat owners; 1,338 bird owners; and 81,953 non-pet owners) enrolled in the Women's Health Initiative observational study and clinical trials. Cox proportional hazards models were used to estimate HR and 95% confidence intervals for the association between pet ownership and cancer, adjusted for potential confounders. There were no significant relationships between ownership of a dog, cat, or bird and incidence of cancer overall. When site-specific cancers were examined, no associations were observed after adjustment for multiple comparisons. Pet ownership had no association with overall cancer incidence. This is the first large epidemiologic study to date to explore relationships between pet ownership and cancer risk, as well as associated risks for individual cancer types. This study requires replication in other sizable, diverse cohorts. Cancer Epidemiol Biomarkers Prev; 25(9); 1311-6. ©2016 AACR. ©2016 American Association for Cancer Research.

  5. Pet Ownership and Cancer Risk in the Women’s Health Initiative

    PubMed Central

    Garcia, David O.; Lander, Eric M.; Wertheim, Betsy C.; Manson, JoAnn E.; Volpe, Stella L.; Chlebowski, Rowan T.; Stefanick, Marcia L.; Lessin, Lawrence S.; Kuller, Lewis H.; Thomson, Cynthia A.

    2016-01-01

    Background Pet ownership and cancer are both highly prevalent in the U.S. Evidence suggest associations may exist between this potentially modifiable factor and cancer prevention, though studies are sparse. The present report examined whether pet ownership (dog, cat, or bird) is associated with lower risk for total cancer and site-specific obesity-related cancers. Methods A prospective analysis of 123,560 participants (20,981 dog owners; 19,288 cat owners; 1,338 bird owners; and 81,953 non-pet owners) enrolled in the Women’s Health Initiative (WHI) observational study and clinical trials. Cox proportional hazards models were used to estimate hazard ratios (HR) and 95% confidence intervals (CI) for the association between pet ownership and cancer, adjusted for potential confounders. Results There were no significant relationships between ownership of a dog, cat, or bird and incidence of cancer overall. When site-specific cancers were examined, no associations were observed after adjustment for multiple comparisons. Conclusion Pet ownership had no association with overall cancer incidence. Impact This is the first large epidemiological study to date to explore relationships between pet ownership and cancer risk, as well as associated risks for individual cancer types. This study requires replication in other sizable, diverse cohorts. PMID:27365150

  6. The effect of recycled plastics and cooking oil on coke quality.

    PubMed

    Lange, Liséte Celina; Ferreira, Alison Frederico Medeiros

    2017-03-01

    This study assessed the effects of adding plastics and waste vegetable oil on the quality of coke in the coking process, on a pilot scale. A typical composition of the main plastics found in municipal solid waste was prepared using 33% HDPE, 5% LDPE, 10% PP, 21% PET, 24.8% PS, 5.2% PVC, 1% cellulose and also a 0.5% waste vegetable oil was added. The wastes were added to the coal blends in the proportions of 1%, 2% and 3% for plastics and 0.5% for vegetable oil. Two types of experiments were performed. The first was carried out in a hearth heating furnace (HHF) at temperatures of up to 900°C for a 7 h period. The second was a box test, which consists of heating coal blends in 18L cans using a pilot coking oven, for approximately 20 h at temperatures between 1050 and 1100°C. The quality parameters used for the assessment were the CSR (coke strength after reaction), CRI (coke reactivity index), ash, volatile matter and sulfur in order to identify the effect of plastic and vegetable oil on coke quality. Results for CSR in the HHF averaged 52.3%, and 56.63% in box test trials. The CRI results ranged from 26.6% to 35.7%. Among the different percentages of plastics used, 3% plastic blends provided the most stable CSR results. The industrial furnaces work at temperatures between 1100 and 1350°C and time coking 21-24h, compared to the test conditions achieved in the HHF and pilot furnace with box test. It was concluded that the results of CSR and CRI are consistent with the tests confirming the feasibility of using plastic in the steelmaking process. Copyright © 2016 Elsevier Ltd. All rights reserved.

  7. Radiation assessment to paediatric with F-18-FDG undergo whole-body PET/CT examination

    NASA Astrophysics Data System (ADS)

    Dhalisa, H.; Mohamad, A. S.; Rafidah, Z.

    2016-01-01

    This study was carried out on wholebody radiation dose assessment to paediatrics patient who undergo PET/CT scanner at Institut Kanser Negara. Consist of 68 patients with varies of malignancies and epilepsy disease case covering age between 2 years to 12 years old. This is a retrospective study from 2010-2014. The use of PET/CT scanner as an advanced tool has been proven to give an extra radiation dose to the patient. It is because of the radiation exposure from the combination of both CT and PET scans rather than a single CT or PET scan. Furthermore, a study on radiation dose to paediatric patient undergoing PET/CT is rare in Malaysia. So, the aim of this study is to estimate the wholebody effective dose to paediatric patient in Malaysia. Effective dose from PET scan was calculated based on the activity of F18 FDG and dose coefficient reported in International Commission on Radiological Protection (ICRP) Publication 106. Effective dose from CT was determined using k coefficient as reported in ICRP publication 102 and Dose Length Product (DLP) value. The average effective dose from PET and CT were found to be 7.05mSv and 5.77mSv respectively. The mean wholebody effective dose received by a patient with combined PETCT examination was 12.78mSv. These results could be used as reference for dosimetry of a patient undergoing PETCT examination in Malaysia.

  8. Radiation assessment to paediatric with F-18-FDG undergo whole-body PET/CT examination

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dhalisa, H., E-mail: dhalisa82@gmail.com; Rafidah, Z.; Mohamad, A. S.

    2016-01-22

    This study was carried out on wholebody radiation dose assessment to paediatrics patient who undergo PET/CT scanner at Institut Kanser Negara. Consist of 68 patients with varies of malignancies and epilepsy disease case covering age between 2 years to 12 years old. This is a retrospective study from 2010-2014. The use of PET/CT scanner as an advanced tool has been proven to give an extra radiation dose to the patient. It is because of the radiation exposure from the combination of both CT and PET scans rather than a single CT or PET scan. Furthermore, a study on radiation dosemore » to paediatric patient undergoing PET/CT is rare in Malaysia. So, the aim of this study is to estimate the wholebody effective dose to paediatric patient in Malaysia. Effective dose from PET scan was calculated based on the activity of F18 FDG and dose coefficient reported in International Commission on Radiological Protection (ICRP) Publication 106. Effective dose from CT was determined using k coefficient as reported in ICRP publication 102 and Dose Length Product (DLP) value. The average effective dose from PET and CT were found to be 7.05mSv and 5.77mSv respectively. The mean wholebody effective dose received by a patient with combined PETCT examination was 12.78mSv. These results could be used as reference for dosimetry of a patient undergoing PETCT examination in Malaysia.« less

  9. A statistical method for lung tumor segmentation uncertainty in PET images based on user inference.

    PubMed

    Zheng, Chaojie; Wang, Xiuying; Feng, Dagan

    2015-01-01

    PET has been widely accepted as an effective imaging modality for lung tumor diagnosis and treatment. However, standard criteria for delineating tumor boundary from PET are yet to develop largely due to relatively low quality of PET images, uncertain tumor boundary definition, and variety of tumor characteristics. In this paper, we propose a statistical solution to segmentation uncertainty on the basis of user inference. We firstly define the uncertainty segmentation band on the basis of segmentation probability map constructed from Random Walks (RW) algorithm; and then based on the extracted features of the user inference, we use Principle Component Analysis (PCA) to formulate the statistical model for labeling the uncertainty band. We validated our method on 10 lung PET-CT phantom studies from the public RIDER collections [1] and 16 clinical PET studies where tumors were manually delineated by two experienced radiologists. The methods were validated using Dice similarity coefficient (DSC) to measure the spatial volume overlap. Our method achieved an average DSC of 0.878 ± 0.078 on phantom studies and 0.835 ± 0.039 on clinical studies.

  10. Pet Dogs and Children’s Health: Opportunities for Chronic Disease Prevention?

    PubMed Central

    Scribani, Melissa B.; Krupa, Nicole; Jenkins, Paul; Nagykaldi, Zsolt; Olson, Ardis L.

    2015-01-01

    Introduction Positive associations between having a pet dog and adult health outcomes have been documented; however, little evidence exists regarding the benefits of pet dogs for young children. This study investigates the hypothesis that pet dogs are positively associated with healthy weight and mental health among children. Methods This cross-sectional study accrued a consecutive sample of children over 18 months in a pediatric primary care setting. The study enrolled 643 children (mean age, 6.7 years); 96% were white, 45% were female, 56% were privately insured, and 58% had pet dogs in the home. Before an annual visit, parents of children aged 4 to 10 years completed the DartScreen, a comprehensive Web-based health risk screener administered using an electronic tablet. The screener domains were child body mass index (BMI), physical activity, screen time, mental health, and pet-related questions. Results Children with and children without pet dogs did not differ in BMI (P = .80), screen time of 2 hours or less (P = 0.99), or physical activity (P = .07). A lower percentage of children with dogs (12%) met the clinical cut-off value of Screen for Child Anxiety and Related Disorders (SCARED-5) of 3 or more, compared with children without dogs (21%, P = .002). The mean SCARED-5 score was lower among children with dogs (1.13) compared with children without dogs (1.40; P = .01). This relationship was retained in multivariate analysis after controlling for several covariates. Conclusions Having a pet dog in the home was associated with a decreased probability of childhood anxiety. Future studies need to establish whether this relationship is causal and, if so, how pet dogs alleviate childhood anxiety. PMID:26605705

  11. Pet Dogs and Children's Health: Opportunities for Chronic Disease Prevention?

    PubMed

    Gadomski, Anne M; Scribani, Melissa B; Krupa, Nicole; Jenkins, Paul; Nagykaldi, Zsolt; Olson, Ardis L

    2015-11-25

    Positive associations between having a pet dog and adult health outcomes have been documented; however, little evidence exists regarding the benefits of pet dogs for young children. This study investigates the hypothesis that pet dogs are positively associated with healthy weight and mental health among children. This cross-sectional study accrued a consecutive sample of children over 18 months in a pediatric primary care setting. The study enrolled 643 children (mean age, 6.7 years); 96% were white, 45% were female, 56% were privately insured, and 58% had pet dogs in the home. Before an annual visit, parents of children aged 4 to 10 years completed the DartScreen, a comprehensive Web-based health risk screener administered using an electronic tablet. The screener domains were child body mass index (BMI), physical activity, screen time, mental health, and pet-related questions. Children with and children without pet dogs did not differ in BMI (P = .80), screen time of 2 hours or less (P = 0.99), or physical activity (P = .07). A lower percentage of children with dogs (12%) met the clinical cut-off value of Screen for Child Anxiety and Related Disorders (SCARED-5) of 3 or more, compared with children without dogs (21%, P = .002). The mean SCARED-5 score was lower among children with dogs (1.13) compared with children without dogs (1.40; P = .01). This relationship was retained in multivariate analysis after controlling for several covariates. Having a pet dog in the home was associated with a decreased probability of childhood anxiety. Future studies need to establish whether this relationship is causal and, if so, how pet dogs alleviate childhood anxiety.

  12. A retrospective comparative study of arthroscopic fixation in acute Rockwood type IV acromioclavicular joint dislocation: single versus double paired Endobutton technique.

    PubMed

    Xu, Jian; Liu, Haifeng; Lu, Wei; Li, Dingfu; Zhu, Weimin; Ouyang, Kan; Wu, Bing; Peng, Liangquan; Wang, Daping

    2018-05-24

    Rockwood type IV acromioclavicular joint (ACJ) dislocation is a trauma usually needs surgical treatment. Paired EndoButton technique (PET) is used in treating such condition. However, the effect of using different types of PET (single versus double PET) for fixation remains controversial. This study aims to evaluate and compare the efficacy of single and double PET and to provide a suitable option for the surgeons. We retrospectively reviewed the charts of patients with acute Rockwood type IV ACJ dislocation who had undergone arthroscopic fixation using single or double PET fixation between March 2009 and March 2015. Seventy-eight consecutive patients identified from chart review were picked and were divided into the single and double PET group with 39 cases in each group. The indexes of visual analog scale score (VAS) for pain, the radiographs of the affected shoulder at different time points of the follow-up, the time of return to activities and sports, the constant functional score, and the Karlsson acromioclavicular joint (ACJ) score, were assessed in a minimum of 2 years postoperation. The average coracoclavicular (CC) and acromioclavicular (AC) distances of the affected joints in the double PET group were significantly smaller than those of the single PET group 2 years postoperation (P < 0.05). The average AC and CC distances in the healthy shoulder joints were significantly smaller than those of the affected joints in the single PET group (P < 0.05); however, these values were not significantly different from those of the affected joints in the double PET group (P > 0.05). The mean VAS pain score was not significantly different, while significant difference was found for the number and times of cases return to activities and sports, constant functional score, and Karlsson ACJ score (P < 0.05) between the two groups. Therefore, the double PET group has better outcome than the single PET group. Complications including redislocation, button slippage, erosion, or AC joint instability occurred in the single PET group, while the complication in the double PET group was rare. Compared with the single PET, the double PET group achieved better outcome with less complications in arthroscopically treating acute Rockwood type IV ACJ dislocation.

  13. Comparison of peritoneal transport characteristics at the second week and at six months of peritoneal dialysis commencement

    PubMed Central

    Balasubramaniyam, R.; Nirmala, V. R.; Yogesh, V.; Sethuraman, R.; Devi, S. Booma; Balakrishnan, N. M.; Bakthavathsalam, G.

    2013-01-01

    Peritoneal equilibration test (PET) is an important tool for managing peritoneal dialysis (PD) prescription. The Kidney Disease Outcomes Quality Initiative (KDOQI) guidelines suggest that the first PET be performed 4-8 weeks after PD commencement. The main reason for this delay is because of the peritoneal membrane might change its character once it is exposed to the glucose based dialysate. In this study, we compared PET 2 weeks after PD commencement to PET after 6 months to evaluate the changes in the peritoneal membrane character with time. This study included 126 patients who underwent PD initiation between March 2007 and December 2011. The PET was performed as per the standard protocol at 2nd week and 6th month after PD initiation. Transport status was categorized as low, low average, high average, and high as per the standard definition. There was no change in transport character in 115 patients (91.2%) between the two PET measurements. When the Early PET at 2nd week and 6th month PET data were analyzed, no significant changes were observed in measured D/P creatinine (0.59 ± 0.14 vs. 0.62 ± 0.14 respectively P = 0.26) and D/D0 Glucose (0.46 ± 0.12 vs. 0.46 ± 0.11, P = 0.65). Using the Bland-Altman analysis the repeatability coefficients were 0.27 and 0.25 for creatinine and glucose values respectively. In our study, the PET performed at the 2nd week are similar to that of the 6th month PET in 91.2% of our patients and the test did not significantly change with time. In conclusion, we could do PET early at 2nd week to assess the peritoneal membrane character and this would help in proper dialysis prescription to the patients. PMID:24049270

  14. Evaluation of MRI and cannabinoid type 1 receptor PET templates constructed using DARTEL for spatial normalization of rat brains

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kronfeld, Andrea; Müller-Forell, Wibke; Buchholz, Hans-Georg

    Purpose: Image registration is one prerequisite for the analysis of brain regions in magnetic-resonance-imaging (MRI) or positron-emission-tomography (PET) studies. Diffeomorphic anatomical registration through exponentiated Lie algebra (DARTEL) is a nonlinear, diffeomorphic algorithm for image registration and construction of image templates. The goal of this small animal study was (1) the evaluation of a MRI and calculation of several cannabinoid type 1 (CB1) receptor PET templates constructed using DARTEL and (2) the analysis of the image registration accuracy of MR and PET images to their DARTEL templates with reference to analytical and iterative PET reconstruction algorithms. Methods: Five male Sprague Dawleymore » rats were investigated for template construction using MRI and [{sup 18}F]MK-9470 PET for CB1 receptor representation. PET images were reconstructed using the algorithms filtered back-projection, ordered subset expectation maximization in 2D, and maximum a posteriori in 3D. Landmarks were defined on each MR image, and templates were constructed under different settings, i.e., based on different tissue class images [gray matter (GM), white matter (WM), and GM + WM] and regularization forms (“linear elastic energy,” “membrane energy,” and “bending energy”). Registration accuracy for MRI and PET templates was evaluated by means of the distance between landmark coordinates. Results: The best MRI template was constructed based on gray and white matter images and the regularization form linear elastic energy. In this case, most distances between landmark coordinates were <1 mm. Accordingly, MRI-based spatial normalization was most accurate, but results of the PET-based spatial normalization were quite comparable. Conclusions: Image registration using DARTEL provides a standardized and automatic framework for small animal brain data analysis. The authors were able to show that this method works with high reliability and validity. Using DARTEL templates together with nonlinear registration algorithms allows for accurate spatial normalization of combined MRI/PET or PET-only studies.« less

  15. Comparison of peritoneal transport characteristics at the second week and at six months of peritoneal dialysis commencement.

    PubMed

    Balasubramaniyam, R; Nirmala, V R; Yogesh, V; Sethuraman, R; Devi, S Booma; Balakrishnan, N M; Bakthavathsalam, G

    2013-09-01

    Peritoneal equilibration test (PET) is an important tool for managing peritoneal dialysis (PD) prescription. The Kidney Disease Outcomes Quality Initiative (KDOQI) guidelines suggest that the first PET be performed 4-8 weeks after PD commencement. The main reason for this delay is because of the peritoneal membrane might change its character once it is exposed to the glucose based dialysate. In this study, we compared PET 2 weeks after PD commencement to PET after 6 months to evaluate the changes in the peritoneal membrane character with time. This study included 126 patients who underwent PD initiation between March 2007 and December 2011. The PET was performed as per the standard protocol at 2(nd) week and 6(th) month after PD initiation. Transport status was categorized as low, low average, high average, and high as per the standard definition. There was no change in transport character in 115 patients (91.2%) between the two PET measurements. When the Early PET at 2(nd) week and 6(th) month PET data were analyzed, no significant changes were observed in measured D/P creatinine (0.59 ± 0.14 vs. 0.62 ± 0.14 respectively P = 0.26) and D/D0 Glucose (0.46 ± 0.12 vs. 0.46 ± 0.11, P = 0.65). Using the Bland-Altman analysis the repeatability coefficients were 0.27 and 0.25 for creatinine and glucose values respectively. In our study, the PET performed at the 2(nd) week are similar to that of the 6(th) month PET in 91.2% of our patients and the test did not significantly change with time. In conclusion, we could do PET early at 2(nd) week to assess the peritoneal membrane character and this would help in proper dialysis prescription to the patients.

  16. Clinical applications with the HIDAC positron camera

    NASA Astrophysics Data System (ADS)

    Frey, P.; Schaller, G.; Christin, A.; Townsend, D.; Tochon-Danguy, H.; Wensveen, M.; Donath, A.

    1988-06-01

    A high density avalanche chamber (HIDAC) positron camera has been used for positron emission tomographic (PET) imaging in three different human studies, including patients presenting with: (I) thyroid diseases (124 cases); (II) clinically suspected malignant tumours of the pharynx or larynx (ENT) region (23 cases); and (III) clinically suspected primary malignant and metastatic tumours of the liver (9 cases, 19 PET scans). The positron emitting radiopharmaceuticals used for the three studies were Na 124I (4.2 d half-life) for the thyroid, 55Co-bleomycin (17.5 h half-life) for the ENT-region and 68Ga-colloid (68 min half-life) for the liver. Tomographic imaging was performed: (I) 24 h after oral Na 124I administration to the thyroid patients, (II) 18 h after intraveneous administration of 55Co-bleomycin to the ENT patients and (III) 20 min following the intraveneous injection of 68Ga-colloid to the liver tumour patients. Three different imaging protocols were used with the HIDAC positron camera to perform appropriate tomographic imaging in each patient study. Promising results were obtained in all three studies, particularly in tomographic thyroid imaging, where a significant clinical contribution is made possible for diagnosis and therapy planning by the PET technique. In the other two PET studies encouraging results were obtained for the detection and precise localisation of malignant tumour disease including an estimate of the functional liver volume based on the reticulo-endothelial-system (RES) of the liver, obtained in vivo, and the three-dimensional display of liver PET data using shaded graphics techniques. The clinical significance of the overall results obtained in both the ENT and the liver PET study, however, is still uncertain and the respective role of PET as a new imaging modality in these applications is not yet clearly established. To appreciate the clinical impact made by PET in liver and ENT malignant tumour staging needs further investigation, and more detailed data on a larger number of clinical and experimental PET scans will be necessary for definitive evaluation. Nevertheless, the HIDAC positron camera may be used for clinical PET imaging in well-defined patient cases, particularly in situations where both high spatial resolution is desired in the reconstructed image of the examined pathological condition and at the same time "static" PET imaging may be adequate, as is the case in thyroid-, ENT- and liver tomographic imaging using the HIDAC positron camera.

  17. Management of Large-Vessel Vasculitis With FDG-PET

    PubMed Central

    Soussan, Michael; Nicolas, Patrick; Schramm, Catherine; Katsahian, Sandrine; Pop, Gabriel; Fain, Olivier; Mekinian, Arsene

    2015-01-01

    Abstract We aimed to clarify the role of 18F-fluorodeoxyglucose positron emission tomography (FDG-PET) in the management of large-vessel vasculitis (LVV), focusing on 3 issues which are as follows: describe and determine the different FDG-PET criteria for the diagnosis of vascular inflammation, the performance of FDG-PET for the diagnosis of large-vessel inflammation in giant cell arteritis (GCA) patients, and the performance of FDG-PET to evaluate the disease inflammatory activity in Takayasu arteritis (TA) patients. MEDLINE, Cochrane Library, and EMBASE database were searched for articles that evaluated the value of FDG-PET in LVV, from January 2000 to December 2013. Inclusion criteria were American College of Rheumatology criteria for GCA or TA, definition PET positivity threshold, and >4 cases included. Sensitivity (Se) and specificity (Sp) of FDG-PET for the diagnosis of large-vessel inflammation were calculated from each included individual study, and then pooled for meta-analysis with a random-effects model. Twenty-one studies (413 patients, 299 controls) were included in the systematic review. FDG-PET showed FDG vascular uptake in 70% (288/413) of patients and 7% (22/299) of controls. Only vascular uptake equal to or higher than the liver uptake was significantly different between GCA/TA patients and controls (P < 0.001). The meta-analysis of GCA patients (4 studies, 57 patients) shows that FDG-PET has high Se and Sp for the diagnosis of large-vessel inflammation in GCA patients in comparison to controls, with a pooled Se at 90% (95% confidence interval [CI], 79%–93%) and a pooled Sp at 98% (95% CI, 94%–99%). The meta-analysis of TA patients (7 studies, 191 patients) shows that FDG-PET has a pooled Se at 87% (95% CI, 78%–93%) and Sp at 73% (95% CI, 63%–81%) for the assessment of disease activity in TA, with up to 84% Sp, with studies using National Institutes of Health criteria as the disease activity assessment scale. FDG-PET showed good performances in the diagnosis of large-vessel inflammation, with higher accuracy in GCA patients than in TA patients. Although a vascular uptake equal to or higher than the liver uptake appears to be a good criterion for the diagnosis of vascular inflammation, further studies are needed to define the threshold of significance as well as the clinical significance of the vascular uptake. PMID:25860208

  18. PET/CT in paediatric malignancies - An update

    PubMed Central

    Padma, Subramanyam; Sundaram, Palaniswamy Shanmuga; Tewari, Anshu

    2016-01-01

    18F-fluorodeoxyglucose positron emission tomography (FDG-PET) is a well-established imaging modality in adult oncological practice. Its role in childhood malignancies needs to be discussed as paediatric malignancies differ from adults in tumor subtypes and they have different tumor biology and FDG uptake patterns. This is also compounded by smaller body mass, dosimetric restrictions, and physiological factors that can affect the FDG uptake. It calls for careful planning of the PET study, preparing the child, the parents, and expertise of nuclear physicians in reporting pediatric positron emission tomography/computed tomography (PET/CT) studies. In a broad perspective, FDG-PET/CT has been used in staging, assessment of therapy response, identifying metastases and as a follow-up tool in a wide variety of pediatric malignancies. This review outlines the role of PET/CT in childhood malignancies other than hematological malignancies such as lymphoma and leukemia. PMID:27688605

  19. Anatomy and function: PET-CT.

    PubMed

    Kajander, Sami; Saraste, Antti; Ukkonen, Heikki; Knuuti, Juhani

    2010-05-01

    CT coronary angiography and perfusion PET form an attractive combination to study coronary artery lesions and their consequences in patients with coronary artery disease. Whereas CT provides non-invasive assessment of coronary lumen and wall, PET perfusion is a reliable method for the evaluation of myocardial flow. CT, although very capable of ruling out significant coronary artery disease, is less than satisfactory in assessing the actual significance of the detected lesions. PET imaging, despite its excellent sensitivity, fails to describe the exact anatomy of the epicardial vessels. By fusing image data from these two modalities, lesions can be accurately correlated with their physiological or anatomical counterparts. Hybrid PET-CT devices, now in wide clinical use, allow such fusion in a one-stop-shop study. Although still seeking its place in clinical scenarios, growing evidence suggests that hybrid PET-CT imaging of coronary anatomy and myocardial perfusion can accurately - and non-invasively - assess the existence and degree of coronary artery disease.

  20. Do TSH, FT3, and FT4 Impact BAT Visualization of Clinical FDG-PET/CT Images?

    PubMed Central

    Nagamachi, Shigeki; Mizutani, Youichi; Terada, Tamasa; Kiyohara, Syogo; Wakamatsu, Hideyuki; Fujita, Seigo; Higashi, Tatsuya; Yoshinaga, Keiichiro; Saga, Tsuneo; Hirai, Toshinori

    2018-01-01

    Objective We retrospectively analyzed activated BAT visualization on FDG-PET/CT in patients with various conditions and TH levels to clarify the relationships between visualization of BAT on FDG-PET/CT and the effect of TH. Methods Patients who underwent clinical FDG-PET/CT were reviewed and we categorized patients into 5 groups: (i) thyroid hormone withdrawal (THW) group; (ii) recombinant human thyrotropin (rhTSH) group; (iii) hypothyroidism group; (iv) hyperthyroidism group; and (v) BAT group. A total of sixty-two FDG-PET/CT imaging studies in fifty-nine patients were performed. To compare each group, gender; age; body weight; serum TSH, FT3, and FT4 levels; and outside temperature were evaluated. Results No significant visualization of BAT was noted in any of the images in the THW, rhTSH, hypothyroidism, and hyperthyroidism groups. All patients in the BAT group were in a euthyroid state. When the BAT-negative and BAT-positive patient groups were compared, it was noted that the minimum and maximum temperature on the day of the PET study and maximum temperature of the one day before the PET study were significantly lower in BAT-positive group than in all those of other groups. Conclusions Elevated TSH condition before RIT, hyperthyroidism, or hypothyroidism did not significantly impact BAT visualization of clinical FDG-PET/CT images. PMID:29666563

  1. MRI-guided attenuation correction in whole-body PET/MR: assessment of the effect of bone attenuation.

    PubMed

    Akbarzadeh, A; Ay, M R; Ahmadian, A; Alam, N Riahi; Zaidi, H

    2013-02-01

    Hybrid PET/MRI presents many advantages in comparison with its counterpart PET/CT in terms of improved soft-tissue contrast, decrease in radiation exposure, and truly simultaneous and multi-parametric imaging capabilities. However, the lack of well-established methodology for MR-based attenuation correction is hampering further development and wider acceptance of this technology. We assess the impact of ignoring bone attenuation and using different tissue classes for generation of the attenuation map on the accuracy of attenuation correction of PET data. This work was performed using simulation studies based on the XCAT phantom and clinical input data. For the latter, PET and CT images of patients were used as input for the analytic simulation model using realistic activity distributions where CT-based attenuation correction was utilized as reference for comparison. For both phantom and clinical studies, the reference attenuation map was classified into various numbers of tissue classes to produce three (air, soft tissue and lung), four (air, lungs, soft tissue and cortical bones) and five (air, lungs, soft tissue, cortical bones and spongeous bones) class attenuation maps. The phantom studies demonstrated that ignoring bone increases the relative error by up to 6.8% in the body and up to 31.0% for bony regions. Likewise, the simulated clinical studies showed that the mean relative error reached 15% for lesions located in the body and 30.7% for lesions located in bones, when neglecting bones. These results demonstrate an underestimation of about 30% of tracer uptake when neglecting bone, which in turn imposes substantial loss of quantitative accuracy for PET images produced by hybrid PET/MRI systems. Considering bones in the attenuation map will considerably improve the accuracy of MR-guided attenuation correction in hybrid PET/MR to enable quantitative PET imaging on hybrid PET/MR technologies.

  2. MR-compatibility assessment of MADPET4: a study of interferences between an SiPM-based PET insert and a 7 T MRI system.

    PubMed

    Omidvari, Negar; Topping, Geoffrey; Cabello, Jorge; Paul, Stephan; Schwaiger, Markus; Ziegler, Sibylle I

    2018-05-01

    Compromises in the design of a positron emission tomography (PET) insert for a magnetic resonance imaging (MRI) system should minimize the deterioration of image quality in both modalities, particularly when simultaneous demanding acquisitions are performed. In this work, the advantages of using individually read-out crystals with high-gain silicon photomultipliers (SiPMs) were studied with a small animal PET insert for a 7 T MRI system, in which the SiPM charge was transferred to outside the MRI scanner using coaxial cables. The interferences between the two systems were studied with three radio-frequency (RF) coil configurations. The effects of PET on the static magnetic field, flip angle distribution, RF noise, and image quality of various MRI sequences (gradient echo, spin echo, and echo planar imaging (EPI) at 1 H frequency, and chemical shift imaging at 13 C frequency) were investigated. The effects of fast-switching gradient fields and RF pulses on PET count rate were studied, while the PET insert and the readout electronics were not shielded. Operating the insert inside a 1 H volume coil, used for RF transmission and reception, limited the MRI to T1-weighted imaging, due to coil detuning and RF attenuation, and resulted in significant PET count loss. Using a surface receive coil allowed all tested MR sequences to be used with the insert, with 45-59% signal-to-noise ratio (SNR) degradation, compared to without PET. With a 1 H/ 13 C volume coil inside the insert and shielded by a copper tube, the SNR degradation was limited to 23-30% with all tested sequences. The insert did not introduce any discernible distortions into images of two tested EPI sequences. Use of truncated sinc shaped RF excitation pulses and gradient field switching had negligible effects on PET count rate. However, PET count rate was substantially affected by high-power RF block pulses and temperature variations due to high gradient duty cycles.

  3. Autism spectrum disorder and pet therapy.

    PubMed

    Siewertsen, Caitlin M; French, Emma D; Teramoto, Masaru

    2015-01-01

    Autism Spectrum Disorder (ASD) encompasses a wide range of social and mental afflictions that are difficult to treat. Due to a lack of established treatments for ASD, alternative therapies have been the primary form of intervention. One of these alternatives is pet therapy, a field that has experienced growing interest and has recently accumulated studies that investigate its efficacy. This article reviews and summarizes that effectiveness as well as the findings and limitations associated with pet therapy for ASD. The majority of research on ASD and pet therapy has examined children and has primarily used dogs and horses for therapy. Studies have shown positive effects for the therapy, including high satisfaction rates among the participants' families. Major limitations of studies in the current literature include the lack of control groups and small sample sizes. Future research should incorporate better study designs and large samples to validate pet therapy as an appropriate treatment for ASD.

  4. Pet-keeping in early childhood and airway, nose and skin symptoms later in life.

    PubMed

    Bornehag, C G; Sundell, J; Hagerhed, L; Janson, S

    2003-09-01

    It is discussed whether exposure to pets during childhood is a risk or a protective factor for sensitization and allergic symptoms. The aim of this study was to investigate the association between pet-keeping at time of birth and allergic symptoms in airways, nose and skin among young children in Sweden. A questionnaire was sent to the parents of 14 077 children (1-6 years), the focus being on allergic symptoms, home environment and other background factors including pet-keeping and avoidance behaviour. The response rate was 79%. Almost one-tenth of the population had got rid of pets because of allergy in the family, and 27.3% reported "avoidance" behaviour towards pets. In a cross-sectional analysis current pet-keeping was "protective", but this may be due to the fact that people avoid exposing their child to something that they believe is a risk factor for allergies. Pet-keeping at the time of birth was associated with "wheezing", "asthma" and "rhinitis on pet-exposure" later in life for children from families with an "avoidance" behaviour, and was not "protective" for other children. There was also an indication of a dose-response relationship between the number of types of furred pets at time of birth and later symptoms in analyses adjusted for avoidance behaviour or current pet-keeping. The distribution of pet-keeping in the population is largely explained by avoidance behaviour, meaning that those who have pets mainly are those who can stand them, indicating a "healthy pet-keeping effect".

  5. Preliminary experience on the use of PET/CT in the management of pediatric post-transplant lymphoproliferative disorder.

    PubMed

    Guerra-García, Pilar; Hirsch, Steffen; Levine, Daniel S; Taj, Mary M

    2017-12-01

    Post-transplant lymphoproliferative disorder (PTLD) is a well-known complication following prolonged immunosuppression. Contrary to other lymphomas, there is no standardized imaging approach to assess PTLD either at staging or for response to therapy. Positron emission tomography/computed tomography (PET/CT) is an imaging modality that has proven to be useful in lymphoma. However, there is still limited data concerning its use in pediatric PTLD. Our study evaluates the use of PET/CT in pediatric PTLD at our institution. To assess the role of PET/CT in pediatric PTLD, we reviewed the pediatric patients with PTLD who had undergone PET/CT at our institution between 2000 and 2016. Nine patients were identified. Six had PET/CT at diagnosis. All lesions seen on CT were identified with PET/CT. Fourteen PET/CTs were done during treatment. Eight PET/CTs were negative, including three where CT showed areas of uncertain significance. In these cases, PET/CT helped us to stop treatment and the patients remain in remission after a long follow-up (mean 74.3 months; range 12.4-180.9 months). PET/CT revealed additional disease in two cases, therefore treatment was intensified. Six biopsies and close follow-up was done to confirm PET/CT results. In one case, PET/CT did not identify central nervous system involvement demonstrated on magnetic resonance imaging. PET/CT may have an important role in the staging and follow-up of pediatric PTLD. In our cohort, PET/CT was helpful in staging and assessing treatment response and in clarifying equivocal findings on other imaging modalities. © 2017 Wiley Periodicals, Inc.

  6. Monitoring contact sensitization to p-phenylenediamine (PPD) by patch testing with PPD 0.3% in petrolatum.

    PubMed

    Geier, Johannes; Ballmer-Weber, Barbara K; Dickel, Heinrich; Frosch, Peter J; Bircher, Andreas; Weisshaar, Elke; Hillen, Uwe

    2013-07-01

    Being a contact allergen of general relevance, p-phenylenediamine (PPD) is patch tested in the baseline series. However, PPD 1% in petrolatum may actively sensitize. Patch testing with PPD at 0.35% pet. proved to be safe, as far as active sensitization is concerned. To determine whether PPD 0.3% pet. reliably detects PPD sensitization. Patch testing with PPD 0.3% pet. and 1% pet. synchronously was performed in consecutive patients in a multicentre study within the Information Network of Departments of Dermatology. Altogether, 2042 patients were patch tested. PPD 1% pet. yielded 6.0% positive reactions (n = 123), and PPD 0.3% pet. yielded 4.7% (n = 95). The synchronous reproducibility of PPD reactions was similar as known from parallel patch tests with identical PPD concentrations. The diagnostic properties of PPD 0.3% pet. expressed as reaction index and positivity ratio were good. Of the 123 patients reacting to PPD 1% pet., 32 (26%) had no positive reaction to PPD 0.3% pet. In 22 of these 32 patients (69%), no clinical relevance could be found. As patch testing with PPD 0.3% pet. is reliable according to our results, we recommend replacing PPD 1% pet. in the baseline series with PPD 0.3% pet. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  7. Clinical utility of flumazenil-PET versus [18F]fluorodeoxyglucose-PET and MRI in refractory partial epilepsy. A prospective study in 100 patients.

    PubMed

    Ryvlin, P; Bouvard, S; Le Bars, D; De Lamérie, G; Grégoire, M C; Kahane, P; Froment, J C; Mauguière, F

    1998-11-01

    We assessed the clinical utility of [11C]flumazenil-PET (FMZ-PET) prospectively in 100 epileptic patients undergoing a pre-surgical evaluation, and defined the specific contribution of this neuro-imaging technique with respect to those of MRI and [18F]fluorodeoxyglucose-PET (FDG-PET). All patients benefited from a long term video-EEG monitoring, whereas an intracranial EEG investigation was performed in 40 cases. Most of our patients (73%) demonstrated a FMZ-PET abnormality; this hit rate was significantly higher in temporal lobe epilepsy (94%) than in other types of epilepsy (50%) (P < 0.001). Most FMZ-PET findings coexisted with a MRI abnormality (81%), including hippocampal atrophy (35%) and focal hypometabolism on FDG-PET (89%). The area of decreased FMZ binding was often smaller than that of glucose hypometabolism (48%) or larger than that of the MRI abnormality (28%). FMZ-PET did not prove superior to FDG-PET in assessing the extent of the ictal onset zone, as defined by intracranial EEG recordings. However, it provided useful data which were complementary to those of MRI and FDG-PET in three situations: (i) in temporal lobe epilepsy associated with MRI signs of hippocampal sclerosis, FMZ-PET abnormalities delineated the site of seizure onset precisely, whenever they were coextensive with FDG-PET abnormalities; (ii) in bi-temporal epilepsy, FMZ-PET helped to confirm the bilateral origin of seizures by showing a specific pattern of decreased FMZ binding in both temporal lobes in 33% of cases; (iii) in patients with a unilateral cryptogenic frontal lobe epilepsy, FMZ-PET provided further evidence of the side and site of seizure onset in 55% of cases. Thus, FMZ-PET deserves to be included in the pre-surgical evaluation of these specific categories of epileptic patients, representing approximately half of the population considered for epilepsy surgery.

  8. The origin and reduction of spurious extrahepatic counts observed in 90Y non-TOF PET imaging post radioembolization

    NASA Astrophysics Data System (ADS)

    Walrand, Stephan; Hesse, Michel; Jamar, François; Lhommel, Renaud

    2018-04-01

    Our literature survey revealed a physical effect unknown to the nuclear medicine community, i.e. internal bremsstrahlung emission, and also the existence of long energy resolution tails in crystal scintillation. None of these effects has ever been modelled in PET Monte Carlo (MC) simulations. This study investigates whether these two effects could be at the origin of two unexplained observations in 90Y imaging by PET: the increasing tails in the radial profile of true coincidences, and the presence of spurious extrahepatic counts post radioembolization in non-TOF PET and their absence in TOF PET. These spurious extrahepatic counts hamper the microsphere delivery check in liver radioembolization. An acquisition of a 32P vial was performed on a GSO PET system. This is the ideal setup to study the impact of bremsstrahlung x-rays on the true coincidence rate when no positron emission and no crystal radioactivity are present. A MC simulation of the acquisition was performed using Gate-Geant4. MC simulations of non-TOF PET and TOF-PET imaging of a synthetic 90Y human liver radioembolization phantom were also performed. Internal bremsstrahlung and long energy resolution tails inclusion in MC simulations quantitatively predict the increasing tails in the radial profile. In addition, internal bremsstrahlung explains the discrepancy previously observed in bremsstrahlung SPECT between the measure of the 90Y bremsstrahlung spectrum and its simulation with Gate-Geant4. However the spurious extrahepatic counts in non-TOF PET mainly result from the failure of conventional random correction methods in such low count rate studies and poor robustness versus emission-transmission inconsistency. A novel proposed random correction method succeeds in cleaning the spurious extrahepatic counts in non-TOF PET. Two physical effects not considered up to now in nuclear medicine were identified to be at the origin of the unusual 90Y true coincidences radial profile. TOF reconstruction removing of the spurious extrahepatic counts was theoretically explained by a better robustness against emission-transmission inconsistency. A novel random correction method was proposed to overcome the issue in non-TOF PET. Further studies are needed to assess the novel random correction method robustness.

  9. Tiny Turtles Purchased at Pet Stores are a Potential High Risk for Salmonella Human Infection in the Valencian Region, Eastern Spain.

    PubMed

    Marin, Clara; Vega, Santiago; Marco-Jiménez, Francisco

    2016-07-01

    Turtles may be considered unsafe pets, particularly in households with children. This study aimed to assess Salmonella carriage by turtles in pet stores and in private ownership to inform the public of the potential health risk, enabling informed choices around pet selection. During the period between September and October 2013, 24 pet stores and 96 private owners were sampled in the Valencian Region (Eastern Spain). Salmonella identification procedure was based on ISO 6579: 2002 recommendations (Annex D). Salmonella strains were serotyped in accordance with Kauffman-White-Le-Minor technique. The rate of isolation of Salmonella was very high from pet store samples (75.0% ± 8.8%) and moderate for private owners (29.0% ± 4.6%). Serotyping revealed 18 different serotypes among two Salmonella enterica subspecies: S. enterica subsp. enterica and S. enterica subsp. diarizonae. Most frequently isolated serotypes were Salmonella Typhimurium (39.5%, 17/43) and Salmonella Pomona (9.3%, 4/43). Serotypes identified have previously been reported in turtles, and child Salmonella infections associate with pet turtle exposure. The present study clearly demonstrates that turtles in pet stores, as well as in private owners, could be a direct or indirect source of a high risk of human Salmonella infections. In addition, pet stores should advise their customers of the potential risks associated with reptile ownership.

  10. PSA levels as a predictor of 68Ga PSMA PET/CT positivity in patients with prostate cancer?

    PubMed

    Soydal, Cigdem; Urun, Yuksel; Suer, Evren; Nak, Demet; Ozkan, Elgin; Kucuk, Ozlem N

    2018-05-10

    The aim of this study is to evaluate predictive factors of 68Gallium (68Ga) Prostate-Specific Membrane Antigen (PSMA) Positron Emission Tomography (PET)/Computed Tomography (CT) positivity. Relationships between serum Prostate Specific Antigen (PSA), Lactate dehydrogenase (LDH) and alkaline phosphatase (ALP) levels, Gleason Score (GS) and positivity of 68Ga PSMA PET in patients who underwent 68Ga PSMA PET/CT for restaging for PCa were evaluated retrospectively. One hundred and four (median age: 67; range: 51-88) patients were included in this study. Of these patients, PSMA PET was positive in 75 (72%) patients. Mean serum PSA levels for PET negative and positive groups were 0.76±1.00 and 180.85±324.93 ng/ml (p<0.001). The sensitivity and specificity of 68Ga PSMA PET/CT for detection of disease recurrence were calculated as 92% and 80%, respectively, for the 1.4 ng/ml PSA cut-off and 92% and 90%, respectively, for the 2 ng/ml PSA cut-off values. The positivity rates for patients with PSA levels <1.4 ng/ml and ≥1.4 ng/ml were 21% and 90%, respectively (p<0.001). 68Ga PSMA PET/CT seems to be a highly sensitive in patients with early PSA recurrence. Patients with higher GS and early PSA recurrence could benefit from 68Ga PSMA PET/CT.

  11. Utility of 18 F-FDG PET/CT scan to diagnose the etiology of fever of unknown origin in patients on dialysis.

    PubMed

    Tek Chand, Kalawat; Chennu, Krishna Kishore; Amancharla Yadagiri, Lakshmi; Manthri Gupta, Ranadheer; Rapur, Ram; Vishnubotla, Siva Kumar

    2017-04-01

    Studies on fever of unknown origin (FUO) in patients of chronic kidney disease and end stage renal disease patients on dialysis were not many. In this study, we used 18 F-FDG PET/CT scan whole body survey for detection of hidden infection, in patients on dialysis, labelled as FUO. In this retrospective study, 20 patients of end stage renal disease on dialysis were investigated for the cause of FUO using 18F-FDG PET/CT scan. All these patients satisfied the definition of FUO as defined by Petersdorf and Beeson. Any focal abnormal site of increased FDG concentration detected by PET/CT, either a solitary or multiple lesions was documented and at least one of the detected abnormal sites of radio tracer concentration was further examined for histopathology. All patients were on renal replacement therapy. Of these, 18 were on hemodialysis and two were on peritoneal dialysis. 18F-FDG PET/CT scan showed metabolically active lesions in 15 patients and metabolically quiescent in five patients. After 18F-FDG PET/CT scan all, but one patient had a change in treatment for fever. Anti-tuberculous treatment was given in 15 patients, antibiotics in four patients and anti-malaria treatment in one patient. The present study is first study of 18F-FDG PET/CT scan in patients of end stage renal disease on dialysis with FUO. The study showed that the 18 F FDG PET/CT scan may present an opportunity to attain the diagnosis in end stage renal disease patients on dialysis with FUO. © 2016 International Society for Hemodialysis.

  12. Thoracic staging in lung cancer: prospective comparison of 18F-FDG PET/MR imaging and 18F-FDG PET/CT.

    PubMed

    Heusch, Philipp; Buchbender, Christian; Köhler, Jens; Nensa, Felix; Gauler, Thomas; Gomez, Benedikt; Reis, Henning; Stamatis, Georgios; Kühl, Hilmar; Hartung, Verena; Heusner, Till A

    2014-03-01

    Therapeutic decisions in non-small cell lung cancer (NSCLC) patients depend on the tumor stage. PET/CT with (18)F-FDG is widely accepted as the diagnostic standard of care. The purpose of this study was to compare a dedicated pulmonary (18)F-FDG PET/MR imaging protocol with (18)F-FDG PET/CT for primary and locoregional lymph node staging in NSCLC patients using histopathology as the reference. Twenty-two patients (12 men, 10 women; mean age ± SD, 65.1 ± 9.1 y) with histopathologically confirmed NSCLC underwent (18)F-FDG PET/CT, followed by (18)F-FDG PET/MR imaging, including a dedicated pulmonary MR imaging protocol. T and N staging according to the seventh edition of the American Joint Committee on Cancer staging manual was performed by 2 readers in separate sessions for (18)F-FDG PET/CT and PET/MR imaging, respectively. Results from histopathology were used as the standard of reference. The mean and maximum standardized uptake value (SUV(mean) and SUV(max), respectively) and maximum diameter of the primary tumor was measured and compared in (18)F-FDG PET/CT and PET/MR imaging. PET/MR imaging and (18)F-FDG PET/CT agreed on T stages in 16 of 16 of patients (100%). All patients were correctly staged by (18)F-FDG PET/CT and PET/MR (100%), compared with histopathology. There was no statistically significant difference between (18)F-FDG PET/CT and (18)F-FDG PET/MR imaging for lymph node metastases detection (P = 0.48). For definition of thoracic N stages, PET/MR imaging and (18)F-FDG PET/CT were concordant in 20 of 22 patients (91%). PET/MR imaging determined the N stage correctly in 20 of 22 patients (91%). (18)F-FDG PET/CT determined the N stage correctly in 18 of 22 patients (82%). The mean differences for SUV(mean) and SUV(max) of NSCLC in (18)F-FDG PET/MR imaging and (18)F-FDG PET/CT were 0.21 and -5.06. These differences were not statistically significant (P > 0.05). The SUV(mean) and SUV(max) measurements derived from (18)F-FDG PET/CT and (18)F-FDG PET/MR imaging exhibited a high correlation (R = 0.74 and 0.86, respectively; P < 0.0001). Size measurements showed an excellent correlation between (18)F-FDG PET/MR imaging and (18)F-FDG PET/CT (R = 0.99; P < 0.0001). The lower and upper limits of agreement between (18)F-FDG PET/CT and (18)F-FDG PET/MR imaging using Bland-Altman analysis were -2.34 to 3.89 for SUV(mean), -7.42 to 4.40 for SUV(max), and -0.59 to 0.83 for the tumor size, respectively. (18)F-FDG PET/MR imaging using a dedicated pulmonary MR imaging protocol, compared with (18)F-FDG PET/CT, does not provide advantages in thoracic staging in NSCLC patients.

  13. Clinical utility of FDG PET/CT in acute complicated pyelonephritis-results from an observational study.

    PubMed

    Wan, Chih-Hsing; Tseng, Jing-Ren; Lee, Ming-Hsun; Yang, Lan-Yan; Yen, Tzu-Chen

    2018-03-01

    Acute complicated pyelonephritis (ACP) is an upper urinary tract infection associated with coexisting urinary tract abnormalities or medical conditions that could predispose to serious outcomes or treatment failures. Although CT and magnetic resonance imaging (MRI) are frequently used in patients with ACP, the clinical value of 18 F-fluorodeoxyglucose positron emission tomography and computed tomography (FDG PET/CT) has not been systematically investigated. This single-center retrospective study was designed to evaluate the potential usefulness of FDG PET/CT in patients with ACP. Thirty-one adult patients with ACP who underwent FDG PET/CT were examined. FDG PET/CT imaging characteristics, including tracer uptake patterns, kidney volumes, and extrarenal imaging findings, were reviewed in combination with clinical data and conventional imaging results. Of the 31 patients, 19 (61%) showed focal FDG uptake. The remaining 12 study participants showed a diffuse FDG uptake pattern. After volumetric approximation, the affected kidneys were found to be significantly enlarged. Patients who showed a focal uptake pattern had a higher frequency of abscess formation requiring drainage. ACP patients showing diffuse tracer uptake patterns had a more benign clinical course. Seven patients had suspected extrarenal coinfections, and FDG PET/CT successfully confirmed the clinical suspicion in five cases. FDG PET/CT was as sensitive as CT in identifying the six patients (19%) who developed abscesses. Notably, FDG PET/CT findings caused a modification to the initial antibiotic regimen in nine patients (29%). FDG PET/CT may be clinically useful in the assessment of patients with ACP who have a progressive disease course.

  14. Clinical utility of FDG PET in Parkinson's disease and atypical parkinsonism associated with dementia.

    PubMed

    Walker, Zuzana; Gandolfo, Federica; Orini, Stefania; Garibotto, Valentina; Agosta, Federica; Arbizu, Javier; Bouwman, Femke; Drzezga, Alexander; Nestor, Peter; Boccardi, Marina; Altomare, Daniele; Festari, Cristina; Nobili, Flavio

    2018-05-19

    There are no comprehensive guidelines for the use of FDG PET in the following three clinical scenarios: (1) diagnostic work-up of patients with idiopathic Parkinson's disease (PD) at risk of future cognitive decline, (2) discriminating idiopathic PD from progressive supranuclear palsy, and (3) identifying the underlying neuropathology in corticobasal syndrome. We therefore performed three literature searches and evaluated the selected studies for quality of design, risk of bias, inconsistency, imprecision, indirectness and effect size. Critical outcomes were the sensitivity, specificity, accuracy, positive/negative predictive value, area under the receiving operating characteristic curve, and positive/negative likelihood ratio of FDG PET in detecting the target condition. Using the Delphi method, a panel of seven experts voted for or against the use of FDG PET based on published evidence and expert opinion. Of 91 studies selected from the three literature searches, only four included an adequate quantitative assessment of the performance of FDG PET. The majority of studies lacked robust methodology due to lack of critical outcomes, inadequate gold standard and no head-to-head comparison with an appropriate reference standard. The panel recommended the use of FDG PET for all three clinical scenarios based on nonquantitative evidence of clinical utility. Despite widespread use of FDG PET in clinical practice and extensive research, there is still very limited good quality evidence for the use of FDG PET. However, in the opinion of the majority of the panellists, FDG PET is a clinically useful imaging biomarker for idiopathic PD and atypical parkinsonism associated with dementia.

  15. Oncologic PET/MRI, part 1: tumors of the brain, head and neck, chest, abdomen, and pelvis.

    PubMed

    Buchbender, Christian; Heusner, Till A; Lauenstein, Thomas C; Bockisch, Andreas; Antoch, Gerald

    2012-06-01

    In oncology, staging forms the basis for prognostic consideration and directly influences patient care by determining the therapeutic approach. Cross-sectional imaging techniques, especially when combined with PET information, play an important role in cancer staging. With the recent introduction of integrated whole-body PET/MRI into clinical practice, a novel metabolic-anatomic imaging technique is now available. PET/MRI seems to be highly accurate in T-staging of tumor entities for which MRI has traditionally been favored, such as squamous cell carcinomas of the head and neck. By adding functional MRI to PET, PET/MRI may further improve diagnostic accuracy in the differentiation of scar tissue from recurrence of tumors such as rectal cancer. This hypothesis will have to be assessed in future studies. With regard to N-staging, PET/MRI does not seem to provide a considerable benefit as compared with PET/CT but provides similar N-staging accuracy when applied as a whole-body staging approach. M-staging will benefit from MRI accuracy in the brain and the liver. The purpose of this review is to summarize the available first experiences with PET/MRI and to outline the potential value of PET/MRI in oncologic applications for which data on PET/MRI are still lacking.

  16. A prototype MR insertable brain PET using tileable GAPD arrays.

    PubMed

    Hong, Key Jo; Choi, Yong; Jung, Jin Ho; Kang, Jihoon; Hu, Wei; Lim, Hyun Keong; Huh, Yoonsuk; Kim, Sangsu; Jung, Ji Woong; Kim, Kyu Bom; Song, Myung Sung; Park, Hyun-Wook

    2013-04-01

    The aim of this study was to develop a prototype magnetic resonance (MR)-compatible positron emission tomography (PET) that can be inserted into a MR imager and that allows simultaneous PET and MR imaging of the human brain. This paper reports the initial results of the authors' prototype brain PET system operating within a 3-T magnetic resonance imaging (MRI) system using newly developed Geiger-mode avalanche photodiode (GAPD)-based PET detectors, long flexible flat cables, position decoder circuit with high multiplexing ratio, and digital signal processing with field programmable gate array-based analog to digital converter boards. A brain PET with 72 detector modules arranged in a ring was constructed and mounted in a 3-T MRI. Each PET module was composed of cerium-doped lutetium yttrium orthosilicate (LYSO) crystals coupled to a tileable GAPD. The GAPD output charge signals were transferred to preamplifiers using 3 m long flat cables. The LYSO and GAPD were located inside the MR bore and all electronics were positioned outside the MR bore. The PET detector performance was investigated both outside and inside the MRI, and MR image quality was evaluated with and without the PET system. The performance of the PET detector when operated inside the MRI during MR image acquisition showed no significant change in energy resolution and count rates, except for a slight degradation in timing resolution with an increase from 4.2 to 4.6 ns. Simultaneous PET/MR images of a hot-rod and Hoffman brain phantom were acquired in a 3-T MRI. Rods down to a diameter of 3.5 mm were resolved in the hot-rod PET image. The activity distribution patterns between the white and gray matter in the Hoffman brain phantom were well imaged. The hot-rod and Hoffman brain phantoms on the simultaneously acquired MR images obtained with standard sequences were observed without any noticeable artifacts, although MR image quality requires some improvement. These results demonstrate that the simultaneous acquisition of PET and MR images is feasible using the MR insertable PET developed in this study.

  17. Performance measurement of PSF modeling reconstruction (True X) on Siemens Biograph TruePoint TrueV PET/CT.

    PubMed

    Lee, Young Sub; Kim, Jin Su; Kim, Kyeong Min; Kang, Joo Hyun; Lim, Sang Moo; Kim, Hee-Joung

    2014-05-01

    The Siemens Biograph TruePoint TrueV (B-TPTV) positron emission tomography (PET) scanner performs 3D PET reconstruction using a system matrix with point spread function (PSF) modeling (called the True X reconstruction). PET resolution was dramatically improved with the True X method. In this study, we assessed the spatial resolution and image quality on a B-TPTV PET scanner. In addition, we assessed the feasibility of animal imaging with a B-TPTV PET and compared it with a microPET R4 scanner. Spatial resolution was measured at center and at 8 cm offset from the center in transverse plane with warm background activity. True X, ordered subset expectation maximization (OSEM) without PSF modeling, and filtered back-projection (FBP) reconstruction methods were used. Percent contrast (% contrast) and percent background variability (% BV) were assessed according to NEMA NU2-2007. The recovery coefficient (RC), non-uniformity, spill-over ratio (SOR), and PET imaging of the Micro Deluxe Phantom were assessed to compare image quality of B-TPTV PET with that of the microPET R4. When True X reconstruction was used, spatial resolution was <3.65 mm with warm background activity. % contrast and % BV with True X reconstruction were higher than those with the OSEM reconstruction algorithm without PSF modeling. In addition, the RC with True X reconstruction was higher than that with the FBP method and the OSEM without PSF modeling method on the microPET R4. The non-uniformity with True X reconstruction was higher than that with FBP and OSEM without PSF modeling on microPET R4. SOR with True X reconstruction was better than that with FBP or OSEM without PSF modeling on the microPET R4. This study assessed the performance of the True X reconstruction. Spatial resolution with True X reconstruction was improved by 45 % and its % contrast was significantly improved compared to those with the conventional OSEM without PSF modeling reconstruction algorithm. The noise level was higher than that with the other reconstruction algorithm. Therefore, True X reconstruction should be used with caution when quantifying PET data.

  18. About Cats and Dogs...Reconsidering the Relationship between Pet Ownership and Health Related Outcomes in Community-Dwelling Elderly

    ERIC Educational Resources Information Center

    Rijken, Mieke; van Beek, Sandra

    2011-01-01

    Having a pet has been claimed to have beneficial health effects, but methodologically sound empirical studies are scarce. Small sample sizes and a lack of information about the specific type of pets involved make it difficult to draw unambiguous conclusions. We aimed to shed light on the relationship between pet ownership and several health…

  19. Noise correlation in PET, CT, SPECT and PET/CT data evaluated using autocorrelation function: a phantom study on data, reconstructed using FBP and OSEM.

    PubMed

    Razifar, Pasha; Sandström, Mattias; Schnieder, Harald; Långström, Bengt; Maripuu, Enn; Bengtsson, Ewert; Bergström, Mats

    2005-08-25

    Positron Emission Tomography (PET), Computed Tomography (CT), PET/CT and Single Photon Emission Tomography (SPECT) are non-invasive imaging tools used for creating two dimensional (2D) cross section images of three dimensional (3D) objects. PET and SPECT have the potential of providing functional or biochemical information by measuring distribution and kinetics of radiolabelled molecules, whereas CT visualizes X-ray density in tissues in the body. PET/CT provides fused images representing both functional and anatomical information with better precision in localization than PET alone. Images generated by these types of techniques are generally noisy, thereby impairing the imaging potential and affecting the precision in quantitative values derived from the images. It is crucial to explore and understand the properties of noise in these imaging techniques. Here we used autocorrelation function (ACF) specifically to describe noise correlation and its non-isotropic behaviour in experimentally generated images of PET, CT, PET/CT and SPECT. Experiments were performed using phantoms with different shapes. In PET and PET/CT studies, data were acquired in 2D acquisition mode and reconstructed by both analytical filter back projection (FBP) and iterative, ordered subsets expectation maximisation (OSEM) methods. In the PET/CT studies, different magnitudes of X-ray dose in the transmission were employed by using different mA settings for the X-ray tube. In the CT studies, data were acquired using different slice thickness with and without applied dose reduction function and the images were reconstructed by FBP. SPECT studies were performed in 2D, reconstructed using FBP and OSEM, using post 3D filtering. ACF images were generated from the primary images, and profiles across the ACF images were used to describe the noise correlation in different directions. The variance of noise across the images was visualised as images and with profiles across these images. The most important finding was that the pattern of noise correlation is rotation symmetric or isotropic, independent of object shape in PET and PET/CT images reconstructed using the iterative method. This is, however, not the case in FBP images when the shape of phantom is not circular. Also CT images reconstructed using FBP show the same non-isotropic pattern independent of slice thickness and utilization of care dose function. SPECT images show an isotropic correlation of the noise independent of object shape or applied reconstruction algorithm. Noise in PET/CT images was identical independent of the applied X-ray dose in the transmission part (CT), indicating that the noise from transmission with the applied doses does not propagate into the PET images showing that the noise from the emission part is dominant. The results indicate that in human studies it is possible to utilize a low dose in transmission part while maintaining the noise behaviour and the quality of the images. The combined effect of noise correlation for asymmetric objects and a varying noise variance across the image field significantly complicates the interpretation of the images when statistical methods are used, such as with statistical estimates of precision in average values, use of statistical parametric mapping methods and principal component analysis. Hence it is recommended that iterative reconstruction methods are used for such applications. However, it is possible to calculate the noise analytically in images reconstructed by FBP, while it is not possible to do the same calculation in images reconstructed by iterative methods. Therefore for performing statistical methods of analysis which depend on knowing the noise, FBP would be preferred.

  20. Reproducibility of Quantitative Brain Imaging Using a PET-Only and a Combined PET/MR System

    PubMed Central

    Lassen, Martin L.; Muzik, Otto; Beyer, Thomas; Hacker, Marcus; Ladefoged, Claes Nøhr; Cal-González, Jacobo; Wadsak, Wolfgang; Rausch, Ivo; Langer, Oliver; Bauer, Martin

    2017-01-01

    The purpose of this study was to test the feasibility of migrating a quantitative brain imaging protocol from a positron emission tomography (PET)-only system to an integrated PET/MR system. Potential differences in both absolute radiotracer concentration as well as in the derived kinetic parameters as a function of PET system choice have been investigated. Five healthy volunteers underwent dynamic (R)-[11C]verapamil imaging on the same day using a GE-Advance (PET-only) and a Siemens Biograph mMR system (PET/MR). PET-emission data were reconstructed using a transmission-based attenuation correction (AC) map (PET-only), whereas a standard MR-DIXON as well as a low-dose CT AC map was applied to PET/MR emission data. Kinetic modeling based on arterial blood sampling was performed using a 1-tissue-2-rate constant compartment model, yielding kinetic parameters (K1 and k2) and distribution volume (VT). Differences for parametric values obtained in the PET-only and the PET/MR systems were analyzed using a 2-way Analysis of Variance (ANOVA). Comparison of DIXON-based AC (PET/MR) with emission data derived from the PET-only system revealed average inter-system differences of −33 ± 14% (p < 0.05) for the K1 parameter and −19 ± 9% (p < 0.05) for k2. Using a CT-based AC for PET/MR resulted in slightly lower systematic differences of −16 ± 18% for K1 and −9 ± 10% for k2. The average differences in VT were −18 ± 10% (p < 0.05) for DIXON- and −8 ± 13% for CT-based AC. Significant systematic differences were observed for kinetic parameters derived from emission data obtained from PET/MR and PET-only imaging due to different standard AC methods employed. Therefore, a transfer of imaging protocols from PET-only to PET/MR systems is not straightforward without application of proper correction methods. Clinical Trial Registration: www.clinicaltrialsregister.eu, identifier 2013-001724-19 PMID:28769742

  1. Assessing spatial associations between thermal stress and mortality in Hong Kong: a small-area ecological study.

    PubMed

    Thach, Thuan-Quoc; Zheng, Qishi; Lai, Poh-Chin; Wong, Paulina Pui-Yun; Chau, Patsy Yuen-Kwan; Jahn, Heiko J; Plass, Dietrich; Katzschner, Lutz; Kraemer, Alexander; Wong, Chit-Ming

    2015-01-01

    Physiological equivalent temperature (PET) is a widely used index to assess thermal comfort of the human body. Evidence on how thermal stress-related health effects vary with small geographical areas is limited. The objectives of this study are (i) to explore whether there were significant patterns of geographical clustering of thermal stress as measured by PET and mortality and (ii) to assess the association between PET and mortality in small geographical areas. A small area ecological cross-sectional study was conducted at tertiary planning units (TPUs) level. Age-standardized mortality rates (ASMR) and monthly deaths at TPUs level for 2006 were calculated for cause-specific diseases. A PET map with 100 m × 100 m resolution for the same period was derived from Hong Kong Urban Climatic Analysis Map data and the annual and monthly averages of PET for each TPU were computed. Global Moran's I and local indicator of spatial association (LISA) analyses were performed. A generalized linear mixed model was used to model monthly deaths against PET adjusted for socio-economic deprivation. We found positive spatial autocorrelation between PET and ASMR. There were spatial correlations between PET and ASMR, particularly in the north of Hong Kong Island, most parts of Kowloon, and across New Territories. A 1°C change in PET was associated with an excess risk (%) of 2.99 (95% CI: 0.50-5.48) for all natural causes, 4.75 (1.14-8.36) for cardiovascular, 7.39 (4.64-10.10) for respiratory diseases in the cool season, and 4.31 (0.12 to 8.50) for cardiovascular diseases in the warm season. Variations between TPUs in PET had an important influence on cause-specific mortality, especially in the cool season. PET may have an impact on the health of socio-economically deprived population groups. Our results suggest that targeting policy interventions at high-risk areas may be a feasible option for reducing PET-related mortality. Copyright © 2014 Elsevier B.V. All rights reserved.

  2. Improvement of attenuation correction in time-of-flight PET/MR imaging with a positron-emitting source.

    PubMed

    Mollet, Pieter; Keereman, Vincent; Bini, Jason; Izquierdo-Garcia, David; Fayad, Zahi A; Vandenberghe, Stefaan

    2014-02-01

    Quantitative PET imaging relies on accurate attenuation correction. Recently, there has been growing interest in combining state-of-the-art PET systems with MR imaging in a sequential or fully integrated setup. As CT becomes unavailable for these systems, an alternative approach to the CT-based reconstruction of attenuation coefficients (μ values) at 511 keV must be found. Deriving μ values directly from MR images is difficult because MR signals are related to the proton density and relaxation properties of tissue. Therefore, most research groups focus on segmentation or atlas registration techniques. Although studies have shown that these methods provide viable solutions in particular applications, some major drawbacks limit their use in whole-body PET/MR. Previously, we used an annulus-shaped PET transmission source inside the field of view of a PET scanner to measure attenuation coefficients at 511 keV. In this work, we describe the use of this method in studies of patients with the sequential time-of-flight (TOF) PET/MR scanner installed at the Icahn School of Medicine at Mount Sinai, New York, NY. Five human PET/MR and CT datasets were acquired. The transmission-based attenuation correction method was compared with conventional CT-based attenuation correction and the 3-segment, MR-based attenuation correction available on the TOF PET/MR imaging scanner. The transmission-based method overcame most problems related to the MR-based technique, such as truncation artifacts of the arms, segmentation artifacts in the lungs, and imaging of cortical bone. Additionally, the TOF capabilities of the PET detectors allowed the simultaneous acquisition of transmission and emission data. Compared with the MR-based approach, the transmission-based method provided average improvements in PET quantification of 6.4%, 2.4%, and 18.7% in volumes of interest inside the lung, soft tissue, and bone tissue, respectively. In conclusion, a transmission-based technique with an annulus-shaped transmission source will be more accurate than a conventional MR-based technique for measuring attenuation coefficients at 511 keV in future whole-body PET/MR studies.

  3. Life cycle assessment of bottled water: A case study of Green2O products.

    PubMed

    Horowitz, Naomi; Frago, Jessica; Mu, Dongyan

    2018-06-01

    This study conducted a full life cycle analysis of bottled water on four types of bottles: ENSO, PLA (corn based), recycled PET, and regular (petroleum based) PET, to discern which bottle material is more beneficial to use in terms of environmental impacts. PET bottles are the conventional bottles used that are not biodegradable and accumulate in landfills. PLA corn based bottles are derived from an organic substance and are degradable under certain environmental conditions. Recycled PET bottles are purified PET bottles that were disposed of and are used in a closed loop system. An ENSO bottle contains a special additive which is designed to help the plastic bottle degrade after disposed of in a landfill. The results showed that of all fourteen impact categories examined, the recycled PET and ENSO bottles were generally better than the PLA and regular PET bottles; however, the ENSO had the highest impacts in the categories of global warming and respiratory organics, and the recycled PET had the highest impact in the eutrophication category. The life cycle stages that were found to have the highest environmental impacts were the bottle manufacturing stage and the bottled water distribution to storage stage. Analysis of the mixed bottle material based on recycled PET resin and regular PET resin was discussed as well, in which key impact categories were identified. The PLA bottle contained extremely low impacts in the carcinogens, respiratory organics and global warming categories, yet it still contained the highest impacts in seven of the fourteen categories. Overall, the results demonstrate that the usage of more sustainable bottles, such as biodegradable ENSO bottles and recycled PET bottles, appears to be a viable option for decreasing impacts of the bottled water industry on the environment. Published by Elsevier Ltd.

  4. Respiratory trace feature analysis for the prediction of respiratory-gated PET quantification.

    PubMed

    Wang, Shouyi; Bowen, Stephen R; Chaovalitwongse, W Art; Sandison, George A; Grabowski, Thomas J; Kinahan, Paul E

    2014-02-21

    The benefits of respiratory gating in quantitative PET/CT vary tremendously between individual patients. Respiratory pattern is among many patient-specific characteristics that are thought to play an important role in gating-induced imaging improvements. However, the quantitative relationship between patient-specific characteristics of respiratory pattern and improvements in quantitative accuracy from respiratory-gated PET/CT has not been well established. If such a relationship could be estimated, then patient-specific respiratory patterns could be used to prospectively select appropriate motion compensation during image acquisition on a per-patient basis. This study was undertaken to develop a novel statistical model that predicts quantitative changes in PET/CT imaging due to respiratory gating. Free-breathing static FDG-PET images without gating and respiratory-gated FDG-PET images were collected from 22 lung and liver cancer patients on a PET/CT scanner. PET imaging quality was quantified with peak standardized uptake value (SUV(peak)) over lesions of interest. Relative differences in SUV(peak) between static and gated PET images were calculated to indicate quantitative imaging changes due to gating. A comprehensive multidimensional extraction of the morphological and statistical characteristics of respiratory patterns was conducted, resulting in 16 features that characterize representative patterns of a single respiratory trace. The six most informative features were subsequently extracted using a stepwise feature selection approach. The multiple-regression model was trained and tested based on a leave-one-subject-out cross-validation. The predicted quantitative improvements in PET imaging achieved an accuracy higher than 90% using a criterion with a dynamic error-tolerance range for SUV(peak) values. The results of this study suggest that our prediction framework could be applied to determine which patients would likely benefit from respiratory motion compensation when clinicians quantitatively assess PET/CT for therapy target definition and response assessment.

  5. Intra-tumour 18F-FDG uptake heterogeneity decreases the reliability on target volume definition with positron emission tomography/computed tomography imaging.

    PubMed

    Dong, Xinzhe; Wu, Peipei; Sun, Xiaorong; Li, Wenwu; Wan, Honglin; Yu, Jinming; Xing, Ligang

    2015-06-01

    This study aims to explore whether the intra-tumour (18) F-fluorodeoxyglucose (FDG) uptake heterogeneity affects the reliability of target volume definition with FDG positron emission tomography/computed tomography (PET/CT) imaging for nonsmall cell lung cancer (NSCLC) and squamous cell oesophageal cancer (SCEC). Patients with NSCLC (n = 50) or SCEC (n = 50) who received (18)F-FDG PET/CT scanning before treatments were included in this retrospective study. Intra-tumour FDG uptake heterogeneity was assessed by visual scoring, the coefficient of variation (COV) of the standardised uptake value (SUV) and the image texture feature (entropy). Tumour volumes (gross tumour volume (GTV)) were delineated on the CT images (GTV(CT)), the fused PET/CT images (GTV(PET-CT)) and the PET images, using a threshold at 40% SUV(max) (GTV(PET40%)) or the SUV cut-off value of 2.5 (GTV(PET2.5)). The correlation between the FDG uptake heterogeneity parameters and the differences in tumour volumes among GTV(CT), GTV(PET-CT), GTV(PET40%) and GTV(PET2.5) was analysed. For both NSCLC and SCEC, obvious correlations were found between uptake heterogeneity, SUV or tumour volumes. Three types of heterogeneity parameters were consistent and closely related to each other. Substantial differences between the four methods of GTV definition were found. The differences between the GTV correlated significantly with PET heterogeneity defined with the visual score, the COV or the textural feature-entropy for NSCLC and SCEC. In tumours with a high FDG uptake heterogeneity, a larger GTV delineation difference was found. Advance image segmentation algorithms dealing with tracer uptake heterogeneity should be incorporated into the treatment planning system. © 2015 The Royal Australian and New Zealand College of Radiologists.

  6. Longitudinal studies of the 18F-FDG kinetics after ipilimumab treatment in metastatic melanoma patients based on dynamic FDG PET/CT.

    PubMed

    Sachpekidis, Christos; Anwar, Hoda; Winkler, Julia K; Kopp-Schneider, Annette; Larribere, Lionel; Haberkorn, Uwe; Hassel, Jessica C; Dimitrakopoulou-Strauss, Antonia

    2018-06-05

    Immunotherapy has raised the issue of appropriate treatment response evaluation, due to the unique mechanism of action of the immunotherapeutic agents. Aim of this analysis is to evaluate the potential role of quantitative analysis of 2-deoxy-2-( 18 F)fluoro-D-glucose ( 18 F-FDG) positron emission tomography/computed tomography (PET/CT) data in monitoring of patients with metastatic melanoma undergoing ipilimumab therapy. 25 patients with unresectable metastatic melanoma underwent dynamic PET/CT (dPET/CT) of the thorax and upper abdomen as well as static, whole body PET/CT with 18 F-FDG before the start of ipilimumab treatment (baseline PET/CT), after two cycles of treatment (interim PET/CT) and at the end of treatment after four cycles (late PET/CT). The evaluation of dPET/CT studies was based on semi-quantitative (standardized uptake value, SUV) calculation as well as quantitative analysis, based on two-tissue compartment modeling and a fractal approach. Patients' best clinical response, assessed at a mean of 59 weeks, was used as reference. According to their best clinical response, patients were dichotomized in those demonstrating clinical benefit (CB, n = 16 patients) and those demonstrating no clinical benefit (no-CB, n = 9 patients). No statistically significant differences were observed between CB and no-CB regarding either semi-quantitative or quantitative parameters in all scans. On contrary, the application of the recently introduced PET response evaluation criteria for immunotherapy (PERCIMT) led to a correct classification rate of 84% (21/25 patients). Quantitative analysis of 18 F-FDG PET data does not provide additional information in treatment response evaluation of metastatic melanoma patients receiving ipilimumab. PERCIMT criteria correlated better with clinical response.

  7. Enhancement of dynamic myocardial perfusion PET images based on low-rank plus sparse decomposition.

    PubMed

    Lu, Lijun; Ma, Xiaomian; Mohy-Ud-Din, Hassan; Ma, Jianhua; Feng, Qianjin; Rahmim, Arman; Chen, Wufan

    2018-02-01

    The absolute quantification of dynamic myocardial perfusion (MP) PET imaging is challenged by the limited spatial resolution of individual frame images due to division of the data into shorter frames. This study aims to develop a method for restoration and enhancement of dynamic PET images. We propose that the image restoration model should be based on multiple constraints rather than a single constraint, given the fact that the image characteristic is hardly described by a single constraint alone. At the same time, it may be possible, but not optimal, to regularize the image with multiple constraints simultaneously. Fortunately, MP PET images can be decomposed into a superposition of background vs. dynamic components via low-rank plus sparse (L + S) decomposition. Thus, we propose an L + S decomposition based MP PET image restoration model and express it as a convex optimization problem. An iterative soft thresholding algorithm was developed to solve the problem. Using realistic dynamic 82 Rb MP PET scan data, we optimized and compared its performance with other restoration methods. The proposed method resulted in substantial visual as well as quantitative accuracy improvements in terms of noise versus bias performance, as demonstrated in extensive 82 Rb MP PET simulations. In particular, the myocardium defect in the MP PET images had improved visual as well as contrast versus noise tradeoff. The proposed algorithm was also applied on an 8-min clinical cardiac 82 Rb MP PET study performed on the GE Discovery PET/CT, and demonstrated improved quantitative accuracy (CNR and SNR) compared to other algorithms. The proposed method is effective for restoration and enhancement of dynamic PET images. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. The current status of positron emission tomography.

    PubMed

    Digby, W; Keppler, J

    2000-01-01

    Positron emission tomography (PET), invented over 25 years ago, is the only imaging technique that provides images of the biological basis of disease. Since disease is a biological process, PET routinely detects disease when other imaging studies, such as CT and MRI, are normal. In addition to its clinical effectiveness, PET has been shown to reduce costs, primarily due to the elimination of other less accurate diagnostic tests and ineffective surgeries. PET has been determined to be applicable to a number of specific applications in the areas of: imaging cancer patients, characterizing myocardial blood flow and viability, and brain imaging in various physiological and pathologic conditions. Tremendous progress has been made in resolving the regulatory and reimbursement issues facing the field of PET. Working with HCFA, representatives of the Institute for Clinical PET and the Society of Nuclear Medicine have brought about expanded HCFA coverage for PET. When HCFA first authorized payment for PET, all coverage decisions were restricted to HCFA and an expanded national coverage policy. HCFA revised its national coverage policy in 1997; this was the first of several steps taken by HCFA towards careful expansion of PET reimbursement. In March 1999, three new indications for whole-body PET scans were added to Medicare's coverage policy. The Institute for Clinical PET is continuing to work with HCFA on continued, appropriate expansion of the coverage policy. This article is partially excerpted from a written statement made by Terry Douglass, Ph.D., president of CTI, Inc., on May 12, 1999, before the Senate Committee on Commerce, Science and Transportation and its Subcommittee on Science, Technology and Space. This was part of the committee's study of "Emerging Technologies in the New Millennium."

  9. The prevalence of carriage of meticillin-resistant staphylococci by veterinary dermatology practice staff and their respective pets.

    PubMed

    Morris, Daniel O; Boston, Raymond C; O'Shea, Kathleen; Rankin, Shelley C

    2010-08-01

    It has been shown that people and pets can harbour identical strains of meticillin-resistant (MR) staphylococci when they share an environment. Veterinary dermatology practitioners are a professional group with a high incidence of exposure to animals infected by Staphylococcus spp. The objective of this study was to assess the prevalence of carriage of MR Staphylococcus aureus (MRSA), MR S. pseudintermedius (MRSP) and MR S. schleiferi (MRSS) by veterinary dermatology practice staff and their personal pets. A swab technique and selective media were used to screen 171 veterinary dermatology practice staff and their respective pets (258 dogs and 160 cats). Samples were shipped by over-night carrier. Human subjects completed a 22-question survey of demographic and epidemiologic data relevant to staphylococcal transmission. The 171 human-source samples yielded six MRSA (3.5%), nine MRSP (5.3%) and four MRSS (2.3%) isolates, while 418 animal-source samples yielded eight MRSA (1.9%) 21 MRSP (5%), and two MRSS (0.5%) isolates. Concordant strains (genetically identical by pulsed-field gel electrophoresis) were isolated from human subjects and their respective pets in four of 171 (2.9%) households: MRSA from one person/two pets and MRSP from three people/three pets. In seven additional households (4.1%), concordant strains were isolated from only the pets: MRSA in two households and MRSP in five households. There were no demographic or epidemiologic factors statistically associated with either human or animal carriage of MR staphylococci, or with concordant carriage by person-pet or pet-pet pairs. Lack of statistical associations may reflect an underpowered study. © 2010 The Authors. Journal compilation © 2010 ESVD and ACVD.

  10. Longer-Term Investigation of the Value of 18F-FDG-PET and Magnetic Resonance Imaging for Predicting the Conversion of Mild Cognitive Impairment to Alzheimer's Disease: A Multicenter Study.

    PubMed

    Inui, Yoshitaka; Ito, Kengo; Kato, Takashi

    2017-01-01

    The value of fluorine-18-fluorodeoxyglucose positron emission tomography (18F-FDG-PET) and magnetic resonance imaging (MRI) for predicting conversion of mild cognitive impairment (MCI) to Alzheimer's disease (AD) in longer-term is unclear. To evaluate longer-term prediction of MCI to AD conversion using 18F-FDG-PET and MRI in a multicenter study. One-hundred and fourteen patients with MCI were followed for 5 years. They underwent clinical and neuropsychological examinations, 18F-FDG-PET, and MRI at baseline. PET images were visually classified into predefined dementia patterns. PET scores were calculated as a semi quantitative index. For structural MRI, z-scores in medial temporal area were calculated by automated volume-based morphometry (VBM). Overall, 72% patients with amnestic MCI progressed to AD during the 5-year follow-up. The diagnostic accuracy of PET scores over 5 years was 60% with 53% sensitivity and 84% specificity. Visual interpretation of PET images predicted conversion to AD with an overall 82% diagnostic accuracy, 94% sensitivity, and 53% specificity. The accuracy of VBM analysis presented little fluctuation through 5 years and it was highest (73%) at the 5-year follow-up, with 79% sensitivity and 63% specificity. The best performance (87.9% diagnostic accuracy, 89.8% sensitivity, and 82.4% specificity) was with a combination identified using multivariate logistic regression analysis that included PET visual interpretation, educational level, and neuropsychological tests as predictors. 18F-FDG-PET visual assessment showed high performance for predicting conversion to AD from MCI, particularly in combination with neuropsychological tests. PET scores showed high diagnostic specificity. Structural MRI focused on the medial temporal area showed stable predictive value throughout the 5-year course.

  11. Respiratory trace feature analysis for the prediction of respiratory-gated PET quantification

    NASA Astrophysics Data System (ADS)

    Wang, Shouyi; Bowen, Stephen R.; Chaovalitwongse, W. Art; Sandison, George A.; Grabowski, Thomas J.; Kinahan, Paul E.

    2014-02-01

    The benefits of respiratory gating in quantitative PET/CT vary tremendously between individual patients. Respiratory pattern is among many patient-specific characteristics that are thought to play an important role in gating-induced imaging improvements. However, the quantitative relationship between patient-specific characteristics of respiratory pattern and improvements in quantitative accuracy from respiratory-gated PET/CT has not been well established. If such a relationship could be estimated, then patient-specific respiratory patterns could be used to prospectively select appropriate motion compensation during image acquisition on a per-patient basis. This study was undertaken to develop a novel statistical model that predicts quantitative changes in PET/CT imaging due to respiratory gating. Free-breathing static FDG-PET images without gating and respiratory-gated FDG-PET images were collected from 22 lung and liver cancer patients on a PET/CT scanner. PET imaging quality was quantified with peak standardized uptake value (SUVpeak) over lesions of interest. Relative differences in SUVpeak between static and gated PET images were calculated to indicate quantitative imaging changes due to gating. A comprehensive multidimensional extraction of the morphological and statistical characteristics of respiratory patterns was conducted, resulting in 16 features that characterize representative patterns of a single respiratory trace. The six most informative features were subsequently extracted using a stepwise feature selection approach. The multiple-regression model was trained and tested based on a leave-one-subject-out cross-validation. The predicted quantitative improvements in PET imaging achieved an accuracy higher than 90% using a criterion with a dynamic error-tolerance range for SUVpeak values. The results of this study suggest that our prediction framework could be applied to determine which patients would likely benefit from respiratory motion compensation when clinicians quantitatively assess PET/CT for therapy target definition and response assessment.

  12. Adhesion of nitrile rubber to UV-assisted surface chemical modified PET fabric, part II: Interfacial characterization of MDI grafted PET

    NASA Astrophysics Data System (ADS)

    Razavizadeh, Mahmoud; Jamshidi, Masoud

    2016-08-01

    Fiber to rubber adhesion is an important subject in rubber industry. It is well known that surface treatment (i.e. physical, mechanical and chemical) is an effective method to improve interfacial bonding of fibers and/or fabrics to rubbers. UV irradiation is an effective method which has been used to increase fabric-rubber interfacial interactions. In this research UV assisted chemical modification of PET fabrics was used to increase PET to nitrile rubber (NBR) adhesion. Nitrile rubber is a perfect selection as fuel and oil resistant rubber. However it has weak bonding to PET fabric. For this purpose PET fabric was carboxylated under UV irradiation and then methylenediphenyl diisocyanate (MDI) was grafted on carboxylated PET. The chemical composition of the fabric before and after surface treatment was investigated by X-ray photoelectron spectroscopy (XPS). The sectional morphology of the experimental PET fibers and the interface between rubber compound and PET fabric was studied using scanning electron microscope (SEM). The morphology and structure of the product were analyzed by an energy dispersive X-ray spectrometer (EDX). FTIR-ATR and H NMR analysis were used to assess surface modifications on the PET irradiated fabrics.

  13. PET/MRI in Oncological Imaging: State of the Art

    PubMed Central

    Bashir, Usman; Mallia, Andrew; Stirling, James; Joemon, John; MacKewn, Jane; Charles-Edwards, Geoff; Goh, Vicky; Cook, Gary J.

    2015-01-01

    Positron emission tomography (PET) combined with magnetic resonance imaging (MRI) is a hybrid technology which has recently gained interest as a potential cancer imaging tool. Compared with CT, MRI is advantageous due to its lack of ionizing radiation, superior soft-tissue contrast resolution, and wider range of acquisition sequences. Several studies have shown PET/MRI to be equivalent to PET/CT in most oncological applications, possibly superior in certain body parts, e.g., head and neck, pelvis, and in certain situations, e.g., cancer recurrence. This review will update the readers on recent advances in PET/MRI technology and review key literature, while highlighting the strengths and weaknesses of PET/MRI in cancer imaging. PMID:26854157

  14. The Role of 18F-FDG PET/CT Integrated Imaging in Distinguishing Malignant from Benign Pleural Effusion.

    PubMed

    Sun, Yajuan; Yu, Hongjuan; Ma, Jingquan; Lu, Peiou

    2016-01-01

    The aim of our study was to evaluate the role of 18F-FDG PET/CT integrated imaging in differentiating malignant from benign pleural effusion. A total of 176 patients with pleural effusion who underwent 18F-FDG PET/CT examination to differentiate malignancy from benignancy were retrospectively researched. The images of CT imaging, 18F-FDG PET imaging and 18F-FDG PET/CT integrated imaging were visually analyzed. The suspected malignant effusion was characterized by the presence of nodular or irregular pleural thickening on CT imaging. Whereas on PET imaging, pleural 18F-FDG uptake higher than mediastinal activity was interpreted as malignant effusion. Images of 18F-FDG PET/CT integrated imaging were interpreted by combining the morphologic feature of pleura on CT imaging with the degree and form of pleural 18F-FDG uptake on PET imaging. One hundred and eight patients had malignant effusion, including 86 with pleural metastasis and 22 with pleural mesothelioma, whereas 68 patients had benign effusion. The sensitivities of CT imaging, 18F-FDG PET imaging and 18F-FDG PET/CT integrated imaging in detecting malignant effusion were 75.0%, 91.7% and 93.5%, respectively, which were 69.8%, 91.9% and 93.0% in distinguishing metastatic effusion. The sensitivity of 18F-FDG PET/CT integrated imaging in detecting malignant effusion was higher than that of CT imaging (p = 0.000). For metastatic effusion, 18F-FDG PET imaging had higher sensitivity (p = 0.000) and better diagnostic consistency with 18F-FDG PET/CT integrated imaging compared with CT imaging (Kappa = 0.917 and Kappa = 0.295, respectively). The specificities of CT imaging, 18F-FDG PET imaging and 18F-FDG PET/CT integrated imaging were 94.1%, 63.2% and 92.6% in detecting benign effusion. The specificities of CT imaging and 18F-FDG PET/CT integrated imaging were higher than that of 18F-FDG PET imaging (p = 0.000 and p = 0.000, respectively), and CT imaging had better diagnostic consistency with 18F-FDG PET/CT integrated imaging compared with 18F-FDG PET imaging (Kappa = 0.881 and Kappa = 0.240, respectively). 18F-FDG PET/CT integrated imaging is a more reliable modality in distinguishing malignant from benign pleural effusion than 18F-FDG PET imaging and CT imaging alone. For image interpretation of 18F-FDG PET/CT integrated imaging, the PET and CT portions play a major diagnostic role in identifying metastatic effusion and benign effusion, respectively.

  15. Local recurrence of prostate cancer after radical prostatectomy is at risk to be missed in 68Ga-PSMA-11-PET of PET/CT and PET/MRI: comparison with mpMRI integrated in simultaneous PET/MRI.

    PubMed

    Freitag, Martin T; Radtke, Jan P; Afshar-Oromieh, Ali; Roethke, Matthias C; Hadaschik, Boris A; Gleave, Martin; Bonekamp, David; Kopka, Klaus; Eder, Matthias; Heusser, Thorsten; Kachelriess, Marc; Wieczorek, Kathrin; Sachpekidis, Christos; Flechsig, Paul; Giesel, Frederik; Hohenfellner, Markus; Haberkorn, Uwe; Schlemmer, Heinz-Peter; Dimitrakopoulou-Strauss, A

    2017-05-01

    The positron emission tomography (PET) tracer 68 Ga-PSMA-11, targeting the prostate-specific membrane antigen (PSMA), is rapidly excreted into the urinary tract. This leads to significant radioactivity in the bladder, which may limit the PET-detection of local recurrence (LR) of prostate cancer (PC) after radical prostatectomy (RP), developing in close proximity to the bladder. Here, we analyze if there is additional value of multi-parametric magnetic resonance imaging (mpMRI) compared to the 68 Ga-PSMA-11-PET-component of PET/CT or PET/MRI to detect LR. One hundred and nineteen patients with biochemical recurrence after prior RP underwent both hybrid 68 Ga-PSMA-11-PET/CT low-dose (1 h p.i.) and -PET/MRI (2-3 h p.i.) including a mpMRI protocol of the prostatic bed. The comparison of both methods was restricted to the abdomen with focus on LR (McNemar). Bladder-LR distance and recurrence size were measured in axial T2w-TSE. A logistic regression was performed to determine the influence of these variables on detectability in 68 Ga-PSMA-11-PET. Standardized-uptake-value (SUV mean ) quantification of LR was performed. There were 93/119 patients that had at least one pathologic finding. In addition, 18/119 Patients (15.1%) were diagnosed with a LR in mpMRI of PET/MRI but only nine were PET-positive in PET/CT and PET/MRI. This mismatch was statistically significant (p = 0.004). Detection of LR using the PET-component was significantly influenced by proximity to the bladder (p = 0.028). The PET-pattern of LR-uptake was classified into three types (1): separated from bladder; (2): fuses with bladder, and (3): obliterated by bladder). The size of LRs did not affect PET-detectability (p = 0.84), mean size was 1.7 ± 0.69 cm long axis, 1.2 ± 0.46 cm short-axis. SUV mean in nine men was 8.7 ± 3.7 (PET/CT) and 7.0 ± 4.2 (PET/MRI) but could not be quantified in the remaining nine cases (obliterated by bladder). The present study demonstrates additional value of hybrid 68 Ga-PSMA-11-PET/MRI by gaining complementary diagnostic information compared to the 68 Ga-PSMA-11-PET/CT low-dose for patients with LR of PC.

  16. Functional neuroimaging of emotional processing in women with polycystic ovary syndrome: a case-control pilot study

    PubMed Central

    Marsh, Courtney A.; Berent-Spillson, Alison; Love, Tiffany; Persad, Carol C.; Pop-Busui, Rodica; Zubieta, Jon-Kar; Smith, Yolanda R.

    2013-01-01

    Objective To evaluate emotional processing in women with insulin-resistant polycystic ovary syndrome (IR-PCOS) and its relationship to glucose regulation and the mu-opioid system. Design Case-control pilot. Setting Tertiary referring medical center. Patient(s) Seven women with IR-PCOS and five non-insulin-resistant controls, aged 21–40 years, recruited from the general population. Intervention(s) Sixteen weeks of metformin (1,500 mg/day) in women with IR-PCOS. Main Outcome Measure(s) Assessment of mood, metabolic function, and neuronal activation during an emotional task using functional magnetic resonance imaging (fMRI), and mu-opioid receptor availability using positive emission tomography (PET). Result(s) We found that insulin-resistant PCOS patients [1] had greater limbic activation during an emotion task than controls (n = 5); [2] trended toward decreased positive affect and increased trait anxiety; [3] after metformin treatment, had limbic activation that no longer differed from controls; and [4] had positive correlations between fMRI limbic activation during emotional processing and mu-opioid binding potential. Conclusion(s) Patients with IR-PCOS had greater regional activation during an emotion task than the controls, although this resolved with metformin therapy. Alterations in mu-opioid neurotransmission may underlie limbic system activity and mood disorders in IR-PCOS. Clinical Trial Registration Number NCT00670800. PMID:23557757

  17. The Alzheimer's Disease Neuroimaging Initiative 2 PET Core: 2015.

    PubMed

    Jagust, William J; Landau, Susan M; Koeppe, Robert A; Reiman, Eric M; Chen, Kewei; Mathis, Chester A; Price, Julie C; Foster, Norman L; Wang, Angela Y

    2015-07-01

    This article reviews the work done in the Alzheimer's Disease Neuroimaging Initiative positron emission tomography (ADNI PET) core over the past 5 years, largely concerning techniques, methods, and results related to amyloid imaging in ADNI. The PET Core has used [(18)F]florbetapir routinely on ADNI participants, with over 1600 scans available for download. Four different laboratories are involved in data analysis, and have examined factors such as longitudinal florbetapir analysis, use of [(18)F]fluorodeoxyglucose (FDG)-PET in clinical trials, and relationships between different biomarkers and cognition. Converging evidence from the PET Core has indicated that cross-sectional and longitudinal florbetapir analyses require different reference regions. Studies have also examined the relationship between florbetapir data obtained immediately after injection, which reflects perfusion, and FDG-PET results. Finally, standardization has included the translation of florbetapir PET data to a centiloid scale. The PET Core has demonstrated a variety of methods for the standardization of biomarkers such as florbetapir PET in a multicenter setting. Copyright © 2015 The Alzheimer's Association. Published by Elsevier Inc. All rights reserved.

  18. MR-assisted PET motion correction in simultaneous PET/MRI studies of dementia subjects.

    PubMed

    Chen, Kevin T; Salcedo, Stephanie; Chonde, Daniel B; Izquierdo-Garcia, David; Levine, Michael A; Price, Julie C; Dickerson, Bradford C; Catana, Ciprian

    2018-03-08

    Subject motion in positron emission tomography (PET) studies leads to image blurring and artifacts; simultaneously acquired magnetic resonance imaging (MRI) data provides a means for motion correction (MC) in integrated PET/MRI scanners. To assess the effect of realistic head motion and MR-based MC on static [ 18 F]-fluorodeoxyglucose (FDG) PET images in dementia patients. Observational study. Thirty dementia subjects were recruited. 3T hybrid PET/MR scanner where EPI-based and T 1 -weighted sequences were acquired simultaneously with the PET data. Head motion parameters estimated from high temporal resolution MR volumes were used for PET MC. The MR-based MC method was compared to PET frame-based MC methods in which motion parameters were estimated by coregistering 5-minute frames before and after accounting for the attenuation-emission mismatch. The relative changes in standardized uptake value ratios (SUVRs) between the PET volumes processed with the various MC methods, without MC, and the PET volumes with simulated motion were compared in relevant brain regions. The absolute value of the regional SUVR relative change was assessed with pairwise paired t-tests testing at the P = 0.05 level, comparing the values obtained through different MR-based MC processing methods as well as across different motion groups. The intraregion voxelwise variability of regional SUVRs obtained through different MR-based MC processing methods was also assessed with pairwise paired t-tests testing at the P = 0.05 level. MC had a greater impact on PET data quantification in subjects with larger amplitude motion (higher than 18% in the medial orbitofrontal cortex) and greater changes were generally observed for the MR-based MC method compared to the frame-based methods. Furthermore, a mean relative change of ∼4% was observed after MC even at the group level, suggesting the importance of routinely applying this correction. The intraregion voxelwise variability of regional SUVRs was also decreased using MR-based MC. All comparisons were significant at the P = 0.05 level. Incorporating temporally correlated MR data to account for intraframe motion has a positive impact on the FDG PET image quality and data quantification in dementia patients. 3 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2018. © 2018 International Society for Magnetic Resonance in Medicine.

  19. Comparison of [68Ga]Ga-PSMA-11 PET/CT with [18F]NaF PET/CT in the evaluation of bone metastases in metastatic prostate cancer patients prior to radionuclide therapy.

    PubMed

    Uprimny, Christian; Svirydenka, Anna; Fritz, Josef; Kroiss, Alexander Stephan; Nilica, Bernhard; Decristoforo, Clemens; Haubner, Roland; von Guggenberg, Elisabeth; Buxbaum, Sabine; Horninger, Wolfgang; Virgolini, Irene Johanna

    2018-05-16

    The purpose of this study was to investigate the diagnostic performance of 68 Ga-PSMA-11 PET/CT in the evaluation of bone metastases in metastatic prostate cancer (PC) patients scheduled for radionuclide therapy in comparison to [ 18 F]sodium fluoride ( 18 F-NaF) PET/CT. Sixteen metastatic PC patients with known skeletal metastases, who underwent both 68 Ga-PSMA-11 PET/CT and 18 F-NaF PET/CT for assessment of metastatic burden prior to radionuclide therapy, were analysed retrospectively. The performance of both tracers was calculated on a lesion-based comparison. Intensity of tracer accumulation of pathologic bone lesions on 18 F-NaF PET and 68 Ga-PSMA-11 PET was measured with maximum standardized uptake values (SUV max ) and compared to background activity of normal bone. In addition, SUV max values of PET-positive bone lesions were analysed with respect to morphologic characteristics on CT. Bone metastases were either confirmed by CT or follow-up PET scan. In contrast to 468 PET-positive lesions suggestive of bone metastases on 18 F-NaF PET, only 351 of the lesions were also judged positive on 68 Ga-PSMA-11 PET (75.0%). Intensity of tracer accumulation of pathologic skeletal lesions was significantly higher on 18 F-NaF PET compared to 68 Ga-PSMA-11 PET, showing a median SUV max of 27.0 and 6.0, respectively (p < 0.001). Background activity of normal bone was lower on 68 Ga-PSMA-11 PET, with a median SUV max of 1.0 in comparison to 2.7 on 18 F-NaF PET; however, tumour to background ratio was significantly higher on 18 F-NaF PET (9.8 versus 5.9 on 68 Ga-PSMA-11 PET; p = 0.042). Based on morphologic lesion characterisation on CT, 18 F-NaF PET revealed median SUV max values of 23.6 for osteosclerotic, 35.0 for osteolytic, and 19.0 for lesions not visible on CT, whereas on 68 Ga-PSMA-11 PET median SUV max values of 5.0 in osteosclerotic, 29.5 in osteolytic, and 7.5 in lesions not seen on CT were measured. Intensity of tracer accumulation between 18 F-NaF PET and 68 Ga-PSMA-11 PET was significantly higher in osteosclerotic (p < 0.001) and lesions not visible on CT (p = 0.012). In comparison to 68 Ga-PSMA-11 PET/CT, 18 F-NaF PET/CT detects a higher number of pathologic bone lesions in advanced stage PC patients scheduled for radionuclide therapy. Our data suggest that 68 Ga-PSMA-11 PET should be combined with 18 F-NaF PET in PC patients with skeletal metastases for restaging prior to initiation or modification of therapy.

  20. Functional imaging in differentiating bronchial masses: an initial experience with a combination of (18)F-FDG PET-CT scan and (68)Ga DOTA-TOC PET-CT scan.

    PubMed

    Kumar, Arvind; Jindal, Tarun; Dutta, Roman; Kumar, Rakesh

    2009-10-01

    To evaluate the role of combination of (18)F-FDG PET-CT scan and (68)Ga DOTA-TOC PET-CT scan in differentiating bronchial tumors observed in contrast enhanced computed tomography scan of chest. Prospective observational study. Place of study: All India Institute of Medical Sciences, New Delhi, India. 7 patients with bronchial mass detected in computed tomography scan of the chest were included in this study. All patients underwent (18)F-FDG PET-CT scan, (68)Ga DOTA-TOC PET-CT scan and fiberoptic bronchoscope guided biopsy followed by definitive surgical excision. The results of functional imaging studies were analyzed and the results are correlated with the final histopathology of the tumor. Histopathological examination of 7 bronchial masses revealed carcinoid tumors (2 typical, 1 atypical), inflammatory myofibroblastic tumor (1), mucoepidermoid carcinoma (1), hamartoma (1), and synovial cell sarcoma (1). The typical carcinoids had mild (18)F-FDG uptake and high (68)Ga DOTA-TOC uptake. Atypical carcinoid had moderate uptake of (18)F-FDG and high (68)Ga DOTA-TOC uptake. Inflammatory myofibroblastic tumor showed high uptake of (18)F-FDG and no uptake of (68)Ga DOTA-TOC. Mucoepidermoid carcinoma showed mild (18)F-FDG uptake and no (68)Ga DOTA-TOC uptake. Hamartoma showed no uptake on either scans. Synovial cell sarcoma showed moderate (18)F-FDG uptake and mild focal (68)Ga DOTA-TOC uptake. This initial experience with the combined use of (18)F-FDG and (68)Ga DOTA-TOC PET-CT scan reveals different uptake patterns in various bronchial tumors. Bronchoscopic biopsy will continue to be the gold standard; however, the interesting observations made in this study merits further evaluation of the utility of the combination of (18)F-FDG PET-CT scan and (68)Ga DOTA-TOC PET-CT scan in larger number of patients with bronchial masses.

  1. 64Cu-PSMA-617 PET/CT Imaging of Prostate Adenocarcinoma: First In-Human Studies.

    PubMed

    Grubmüller, Bernhard; Baum, Richard P; Capasso, Enza; Singh, Aviral; Ahmadi, Yasaman; Knoll, Peter; Floth, Andreas; Righi, Sergio; Zandieh, Shahin; Meleddu, Carlo; Shariat, Shahrokh F; Klingler, Hans Christoph; Mirzaei, Siroos

    2016-10-07

    The prostate-specific membrane antigen (PSMA) is a cell surface protein, which is overexpressed in nearly all cases of prostate cancer (PCa). PET imaging with 68 Ga-PSMA-HBED-CC has recently found widespread application in the diagnosis of recurrent PCa. In this study, the diagnostic potential of 64 Cu-labeled PSMA ligand (PSMA-617) PET in patients with PCa has been investigated. The study was conducted simultaneously at two nuclear medicine centers, Austria (Vienna, Center 1) and Germany (Bad Berka, Center 2). The patients (n = 29) included in this study were referred for PET (Center 1, 21 patients) or PET/CT (Center 2, 8 patients) imaging with either a high suspicion of recurrent disease or for possible surgical or PSMA radioligand therapy planning. PET images of the whole body were performed at 1 hour p.i. and additional images of the pelvis at 2 hours p.i. In 23 of 29 patients, at least one focus of pathological tracer uptake suspicious for primary disease in the prostate lobe or recurrent disease was detected. Among healthy organs, the salivary glands, kidneys, and liver showed the highest radiotracer uptake. Lesions suspicious for PCa were detected with excellent contrast as early as 1 hour p.i. with high detection rates even at low prostate-specific antigen (PSA) levels. The preliminary results of this study demonstrate the high potential of 64 Cu-PSMA ligand PET/CT imaging in patients with recurrent disease and in the primary staging of selected patients with progressive local disease. The acquired PET images showed an excellent resolution of the detected lesions with very high lesion-to- background contrast. Furthermore, the long half-life of 64 Cu allows distribution of the tracer to clinical PET centers that lack radiochemistry facilities for the preparation of 68 Ga-PSMA ligand (satellite concept).

  2. Positron Emission Tomography/Computed Tomography in the Staging and Treatment of Anal Cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sveistrup, Joen, E-mail: joensveistrup@hotmail.com; Loft, Annika; Berthelsen, Anne Kiil

    2012-05-01

    Purpose: This study was intended to determine the role of PET/CT in the staging of anal cancer as a supplement to three-dimensional transanal ultrasound (TAUS) and inguinal ultrasound (US). The impact of the PET/CT on the initial stage and treatment plan proposed by TAUS/US was assessed. Methods and Materials: Ninety-five (95) patients referred to our clinic between July 1, 2005, and December 31, 2009, were retrospectively reviewed. All patients had biopsy-proven primary squamous cell cancer of the anal canal. There were 65 females (68%) and 30 males (32%), and the median age was 58 years (range, 35-88 years). Six (6%)more » of the patients were HIV positive. All patients were staged with TAUS/US and PET/CT. Results: Twenty-eight (28) patients were diagnosed with suspicious perirectal node metastases. TAUS visualized 24 of these, whereas PET/CT detected 15. Suspicious inguinal nodes were visualized on either US or PET/CT in 41 patients. Seventeen (17) of these had confirmed malignant disease on biopsy, and 15 had confirmed benign disease. All 17 patients (100%) with malignant inguinal nodes were diagnosed by PET/CT, whereas US identified 16 (94%). Ten patients were diagnosed with suspicious inguinal nodes on PET/CT that had not been seen on US. One of these was malignant, three were benign, and six were not biopsied. PET/CT diagnosed eight metastatic sites, whereas TAUS/US diagnosed three. PET/CT discovered three of the five synchronous cancers seen in this study. PET/CT upstaged the disease in 14% of the cases and changed the treatment plan proposed by TAUS/US in 17%. Conclusion: PET/CT has great potential influence on the staging and treatment of anal cancer. TAUS is important in the staging of the primary tumor and N1-stage, whereas PET/CT seems necessary for the N2/3-stage, the M-stage and synchronous cancers.« less

  3. Reproducibility of functional volume and activity concentration in 18F-FDG PET/CT of liver metastases in colorectal cancer.

    PubMed

    Heijmen, Linda; de Geus-Oei, Lioe-Fee; de Wilt, Johannes H W; Visvikis, Dimitris; Hatt, Mathieu; Visser, Eric P; Bussink, Johan; Punt, Cornelis J A; Oyen, Wim J G; van Laarhoven, Hanneke W M

    2012-12-01

    Several studies showed potential for monitoring response to systemic therapy in metastatic colorectal cancer patients with (18)F-fluorodeoxyglucose (FDG) positron emission tomography (PET). Before (18)F-FDG PET can be implemented for response evaluation the repeatability should be known. This study was performed to assess the magnitude of the changes in standardized uptake value (SUV), volume and total lesion glycolysis (TLG) in colorectal liver metastases and validate the biological basis of (18)F-FDG PET in colorectal liver metastases. Twenty patients scheduled for liver metastasectomy underwent two (18)F-FDG PET scans within 1 week. Bland-Altman analysis was performed to assess repeatability of SUV(max), SUV(mean), volume and TLG. Tumours were delineated using an adaptive threshold method (PET(SBR)) and a semiautomatic fuzzy locally adaptive Bayesian (FLAB) delineation method. Coefficient of repeatability of SUV(max) and SUV(mean) were ∼39 and ∼31 %, respectively, independent of the delineation method used and image reconstruction parameters. However, repeatability was worse in recently treated patients. The FLAB delineation method improved the repeatability of the volume and TLG measurements compared to PET(SBR), from coefficients of repeatability of over 85 % to 45 % and 57 % for volume and TLG, respectively. Glucose transporter 1 (GLUT1) expression correlated to the SUV(mean). Vascularity (CD34 expression) and tumour hypoxia (carbonic anhydrase IX expression) did not correlate with (18)F-FDG PET parameters. In conclusion, repeatability of SUV(mean) and SUV(max) was mainly affected by preceding systemic therapy. The repeatability of tumour volume and TLG could be improved using more advanced and robust delineation approaches such as FLAB, which is recommended when (18)F-FDG PET is utilized for volume or TLG measurements. Improvement of repeatability of PET measurements, for instance by dynamic PET scanning protocols, is probably necessary to effectively use PET for early response monitoring.

  4. Diagnostic value of contrast-enhanced CT combined with 18-FDG PET in patients selected for cytoreductive surgery and hyperthermic intraperitoneal chemotherapy (HIPEC).

    PubMed

    Sommariva, Antonio; Evangelista, Laura; Pintacuda, Giovanna; Cervino, Anna Rita; Ramondo, Gaetano; Rossi, Carlo Riccardo

    2018-05-01

    Aim of the study is to assess the reliability and correlation with surgical peritoneal cancer index (PCI) of combined PET/CT and ceCT scans (PET/ceCT) performed in a session in patients with peritoneal carcinomatosis candidates for cytoreductive surgery (CS) and hyperthermic intraperitoneal chemotherapy (HIPEC). We retrospectively analyzed data collected from 27 patients with different types of peritoneal carcinomatosis candidates to CS + HIPEC who underwent FDG PET/ceCT in a single session. Two nuclear medicine physicians and two radiologists independently and blindly evaluated PET/CT and ceCT imaging, respectively. In the case of discordance, the consensus was reached by a discussion between the specialists. Moreover, the combined images were evaluated by all the specialists in consensus. The PCIs obtained from surgical look, PET/CT, ceCT, and PET/ceCT were compared with each other. The coefficients of correlation (r) were calculated. The study was conducted after approval of local ethics committee. Surgical PCI was available in 21 patients. The coefficient of correlation between PCI of PET/CT and surgery was 0.528, while it resulted higher between PET/ceCT and surgery (r = 0.878), very similar to ceCT and surgery (r = 0.876). The r coefficient between surgical PCI and PET/CT was higher in patients with a non-mucinous cancer (n = 12) than the counterpart (0.601 vs. 0.303) and the addition of ceCT significantly increases the correlation (r = 0.863), which is anyway similar to ceCT alone (r = 0.856). PET/ceCT as single examination is more accurate than PET/CT but not than ceCT alone for the definition of PCI in a selected group of patients candidates to CS + HIPEC.

  5. Interim Positron Emission Tomography Response-Adapted Therapy in Advanced-Stage Hodgkin Lymphoma: Final Results of the Phase II Part of the HD0801 Study.

    PubMed

    Zinzani, Pier Luigi; Broccoli, Alessandro; Gioia, Daniela Maria; Castagnoli, Antonio; Ciccone, Giovannino; Evangelista, Andrea; Santoro, Armando; Ricardi, Umberto; Bonfichi, Maurizio; Brusamolino, Ercole; Rossi, Giuseppe; Anastasia, Antonella; Zaja, Francesco; Vitolo, Umberto; Pavone, Vincenzo; Pulsoni, Alessandro; Rigacci, Luigi; Gaidano, Gianluca; Stelitano, Caterina; Salvi, Flavia; Rusconi, Chiara; Tani, Monica; Freilone, Roberto; Pregno, Patrizia; Borsatti, Eugenio; Sacchetti, Gian Mauro; Argnani, Lisa; Levis, Alessandro

    2016-04-20

    The clinical impact of positron emission tomography (PET) evaluation performed early during first-line therapy in patients with advanced-stage Hodgkin lymphoma, in terms of providing a rationale to shift patients who respond poorly onto a more intensive regimen (PET response-adapted therapy), remains to be confirmed. The phase II part of the multicenter HD0801 study involved 519 patients with advanced-stage de novo Hodgkin lymphoma who received an initial treatment with doxorubicin, bleomycin, vinblastine, and dacarbazine (ABVD) and who underwent an early ifosfamide-containing salvage treatment followed by stem-cell transplantation if they showed a positive PET evaluation after two cycles of chemotherapy (PET2). The primary end point was 2-year progression-free survival calculated for both PET2-negative patients (who completed a full six cycles of ABVD treatment) and PET2-positive patients. Overall survival was a secondary end point. In all, 103 of the 512 evaluable patients were PET2 positive. Among them, 81 received the scheduled salvage regimen with transplantation, 15 remained on ABVD (physician's decision, mostly because of minimally positive PET2), five received an alternative treatment, and two were excluded because of diagnostic error. On intention-to-treat analysis, the 2-year progression-free survival was 76% for PET2-positive patients (regardless of the salvage treatment they received) and 81% for PET2-negative patients. Patients with advanced-stage Hodgkin lymphoma for whom treatment was at high risk of failing appear to benefit from early treatment intensification with autologous transplantation, as indicated by the possibility of successful salvage treatment in more than 70% of PET2-positive patients through obtaining the same 2-year progression-free survival as the PET2-negative subgroup. © 2016 by American Society of Clinical Oncology.

  6. 18 F-Fluorodeoxyglucose-Positron Emission Tomography As an Imaging Biomarker in a Prospective, Longitudinal Cohort of Patients With Large Vessel Vasculitis.

    PubMed

    Grayson, Peter C; Alehashemi, Sara; Bagheri, Armin A; Civelek, Ali Cahid; Cupps, Thomas R; Kaplan, Mariana J; Malayeri, Ashkan A; Merkel, Peter A; Novakovich, Elaine; Bluemke, David A; Ahlman, Mark A

    2018-03-01

    To assess the clinical value of 18 F-fluorodeoxyglucose (FDG) positron emission tomography (PET) in a prospective cohort of patients with large vessel vasculitis (LVV) and comparator subjects. Patients with Takayasu arteritis and giant cell arteritis were studied, along with a comparator group consisting of patients with hyperlipidemia, patients with diseases that mimic LVV, and healthy controls. Participants underwent clinical evaluation and FDG-PET imaging, and patients with LVV underwent serial imaging at 6-month intervals. We calculated sensitivity and specificity of FDG-PET interpretation for distinguishing patients with clinically active LVV from comparator subjects and from patients with disease in clinical remission. A qualitative summary score based on global arterial FDG uptake, the PET Vascular Activity Score (PETVAS), was used to study associations between activity on PET scan and clinical characteristics and to predict relapse. A total of 170 FDG-PET scans were performed in 115 participants (56 patients with LVV and 59 comparator subjects). FDG-PET distinguished patients with clinically active LVV from comparator subjects with a sensitivity of 85% (95% confidence interval [95% CI] 69, 94) and a specificity of 83% (95% CI 71, 91). FDG-PET scans were interpreted as active vasculitis in most patients with LVV in clinical remission (41 of 71 [58%]). Clinical disease activity status, disease duration, body mass index, and glucocorticoid use were independently associated with activity on PET scan. Among patients who underwent PET during clinical remission, future clinical relapse was more common in patients with a high PETVAS than in those with a low PETVAS (55% versus 11%; P = 0.03) over a median follow-up period of 15 months. FDG-PET provides information about vascular inflammation that is complementary to, and distinct from, clinical assessment in LVV. FDG-PET scan activity during clinical remission was associated with future clinical relapse. © 2017, American College of Rheumatology.

  7. Improved quantitation and reproducibility in multi-PET/CT lung studies by combining CT information.

    PubMed

    Holman, Beverley F; Cuplov, Vesna; Millner, Lynn; Endozo, Raymond; Maher, Toby M; Groves, Ashley M; Hutton, Brian F; Thielemans, Kris

    2018-06-05

    Matched attenuation maps are vital for obtaining accurate and reproducible kinetic and static parameter estimates from PET data. With increased interest in PET/CT imaging of diffuse lung diseases for assessing disease progression and treatment effectiveness, understanding the extent of the effect of respiratory motion and establishing methods for correction are becoming more important. In a previous study, we have shown that using the wrong attenuation map leads to large errors due to density mismatches in the lung, especially in dynamic PET scans. Here, we extend this work to the case where the study is sub-divided into several scans, e.g. for patient comfort, each with its own CT (cine-CT and 'snap shot' CT). A method to combine multi-CT information into a combined-CT has then been developed, which averages the CT information from each study section to produce composite CT images with the lung density more representative of that in the PET data. This combined-CT was applied to nine patients with idiopathic pulmonary fibrosis, imaged with dynamic 18 F-FDG PET/CT to determine the improvement in the precision of the parameter estimates. Using XCAT simulations, errors in the influx rate constant were found to be as high as 60% in multi-PET/CT studies. Analysis of patient data identified displacements between study sections in the time activity curves, which led to an average standard error in the estimates of the influx rate constant of 53% with conventional methods. This reduced to within 5% after use of combined-CTs for attenuation correction of the study sections. Use of combined-CTs to reconstruct the sections of a multi-PET/CT study, as opposed to using the individually acquired CTs at each study stage, produces more precise parameter estimates and may improve discrimination between diseased and normal lung.

  8. Exposure to pets and atopic dermatitis during the first two years of life. A cohort study.

    PubMed

    Zirngibl, Angelika; Franke, Kaethe; Gehring, Ulrike; von Berg, Andrea; Berdel, Dietrich; Bauer, Carl Peter; Reinhardt, Dietrich; Wichmann, H-Erich; Heinrich, Joachim

    2002-12-01

    The aim of this study was to assess the association between keeping pets in early childhood and the occurrence of atopic dermatitis in an ongoing birth cohort followed up to the age of 2 years. We analyzed data of 4578 children in the intervention and observation part of an ongoing cohort study. The children were recruited at birth in the two study regions Wesel and Munich between January 1996 and June 1998. Information on atopic diseases and pet ownership was obtained by questionnaire at the child's first and second birthday. The logistic regression model showed a negative association between 'keeping any pet' and in particular 'keeping dogs' in the 1st year of life and the development of atopic dermatitis in the 1st and the 2nd years of life. The protective effects remained statistically significant after adjusting for several possible confounding variables (1st year(any) pet OR 0.71, 95% CI [0.55;0.92], 1st year(dog) OR 0.62, 95% CI [0.39;0.98], 2nd year(any) pet OR 0.74, 95% CI [0.57;0.97], 2nd year(dog) OR 0.63, 95% CI [0.40;0.98]). Ownership of small furred pets (hamster, rabbit and guinea pig) also showed a borderline protective effect for the 1st year. We assume an association between keeping pets and undefined environmental factor(s) that contribute protectively to the development of atopic dermatitis in early life, presumably by effects on the maturation of the immune system.

  9. 68Ga-PSMA-PET/CT in Patients With Biochemical Prostate Cancer Recurrence and Negative 18F-Choline-PET/CT.

    PubMed

    Bluemel, Christina; Krebs, Markus; Polat, Bülent; Linke, Fränze; Eiber, Matthias; Samnick, Samuel; Lapa, Constantin; Lassmann, Michael; Riedmiller, Hubertus; Czernin, Johannes; Rubello, Domenico; Bley, Thorsten; Kropf, Saskia; Wester, Hans-Juergen; Buck, Andreas K; Herrmann, Ken

    2016-07-01

    Investigating the value of Ga-PSMA-PET/CT in biochemically recurring prostate cancer patients with negative F-choline-PET/CT. One hundred thirty-nine consecutive patients with biochemical recurrence after curative (surgery and/or radiotherapy) therapy were offered participation in this sequential clinical imaging approach. Patients first underwent an F-choline-PET/CT. If negative, an additional Ga-PSMA-PET/CT was offered. One hundred twenty-five of 139 eligible patients were included in the study; 32 patients underwent additional Ga-PSMA-PET/CT. Patients with equivocal findings (n = 5) on F-choline-PET/CT and those who declined the additional Ga-PSMA-PET/CT (n = 9) were excluded. Images were analyzed visually for the presence of suspicious lesions. Findings on PET/CT were correlated with PSA level, PSA doubling time (dt), and PSA velocity (vel). The overall detection rates were 85.6% (107/125) for the sequential imaging approach and 74.4% (93/125) for F-choline-PET/CT alone. Ga-PSMA-PET/CT detected sites of recurrence in 43.8% (14/32) of the choline-negative patients. Detection rates of the sequential imaging approach and F-choline-PET/CT alone increased with higher serum PSA levels and PSA vel. Subgroup analysis of Ga-PSMA-PET/CT in F-choline negative patients revealed detection rates of 28.6%, 45.5%, and 71.4% for PSA levels of 0.2 or greater to less than 1 ng/mL, 1 to 2 ng/mL, and greater than 2 ng/mL, respectively. The sequential imaging approach designed to limit Ga-PSMA imaging to patients with negative choline scans resulted in high detection rates. Ga-PSMA-PET/CT identified sites of recurrent disease in 43.8% of the patients with negative F-choline PET/CT scans.

  10. 68Ga-PSMA-PET/CT in Patients With Biochemical Prostate Cancer Recurrence and Negative 18F-Choline-PET/CT

    PubMed Central

    Bluemel, Christina; Krebs, Markus; Polat, Bülent; Linke, Fränze; Eiber, Matthias; Samnick, Samuel; Lapa, Constantin; Lassmann, Michael; Riedmiller, Hubertus; Czernin, Johannes; Rubello, Domenico; Bley, Thorsten; Kropf, Saskia; Wester, Hans-Juergen; Buck, Andreas K.; Herrmann, Ken

    2016-01-01

    Purpose Investigating the value of 68Ga-PSMA-PET/CT in biochemically recurring prostate cancer patients with negative 18F-choline-PET/CT. Patients and Methods One hundred thirty-nine consecutive patients with biochemical recurrence after curative (surgery and/or radiotherapy) therapy were offered participation in this sequential clinical imaging approach. Patients first underwent an 18F-choline-PET/CT. If negative, an additional 68Ga-PSMA-PET/CTwas offered. One hundred twenty-five of 139 eligible patients were included in the study; 32 patients underwent additional 68Ga-PSMA-PET/CT. Patients with equivocal findings (n = 5) on 18F-choline-PET/CT and those who declined the additional 68Ga-PSMA-PET/CT (n = 9) were excluded. Images were analyzed visually for the presence of suspicious lesions. Findings on PET/CT were correlated with PSA level, PSA doubling time (dt), and PSA velocity (vel). Results The overall detection rates were 85.6% (107/125) for the sequential imaging approach and 74.4% (93/125) for 18F-choline-PET/CT alone. 68Ga-PSMA-PET/CT detected sites of recurrence in 43.8% (14/32) of the choline-negative patients. Detection rates of the sequential imaging approach and 18F-choline-PET/CT alone increased with higher serum PSA levels and PSA vel. Subgroup analysis of 68Ga-PSMA-PET/CT in 18F-choline negative patients revealed detection rates of 28.6%, 45.5%, and 71.4% for PSA levels of 0.2 or greater to less than 1 ng/mL, 1 to 2 ng/mL, and greater than 2 ng/mL, respectively. Conclusions The sequential imaging approach designed to limit 68Ga-PSMA imaging to patients with negative choline scans resulted in high detection rates. 68Ga-PSMA-PET/CT identified sites of recurrent disease in 43.8% of the patients with negative 18F-choline PET/CT scans. PMID:26975008

  11. Pet ownership and health in older adults: findings from a survey of 2,551 community-based Australians aged 60-64.

    PubMed

    Parslow, Ruth A; Jorm, Anthony F; Christensen, Helen; Rodgers, Bryan; Jacomb, Patricia

    2005-01-01

    It is commonly assumed that owning a pet provides older residents in the community with health benefits including improved physical health and psychological well-being. It has also been reported that pet owners are lower on neuroticism and higher on extraversion compared with those without pets. However, findings of research on this topic have been mixed with a number of researchers reporting that, for older people, there is little or no health benefit associated with pet ownership. To identify health benefits associated with pet ownership and pet caring responsibilities in a large sample of older community-based residents. Using survey information provided by 2,551 individuals aged between 60 and 64 years, we compared the sociodemographic attributes, mental and physical health measures, and personality traits of pet owners and non-owners. For 78.8% of these participants, we were also able to compare the health services used, based on information obtained from the national insurer on the number of general practitioner (GP) visits they made over a 12-month period. Compared with non-owners, those with pets reported more depressive symptoms while female pet owners who were married also had poorer physical health. We found that caring for a pet was associated with negative health outcomes including more symptoms of depression, poorer physical health and higher rates of use of pain relief medication. No relationship was found between pet ownership and use of GP services. When we examined the personality traits of pet owners and carers, we found that men who cared for pets had higher extraversion scores. Our principal and unexpected finding, however, was that pet owners and carers reported higher levels of psychoticism as measured by the Revised Eysenck Personality Questionnaire. We conclude that pet ownership confers no health benefits for this age group. Instead, those with pets have poorer mental and physical health and use more pain relief medication. Further, our study suggests that those with pets are less conforming to social norms as indicated by their higher levels of psychoticism. Copyright (c) 2005 S. Karger AG, Basel

  12. Value of a Dixon-based MR/PET attenuation correction sequence for the localization and evaluation of PET-positive lesions.

    PubMed

    Eiber, Matthias; Martinez-Möller, Axel; Souvatzoglou, Michael; Holzapfel, Konstantin; Pickhard, Anja; Löffelbein, Dennys; Santi, Ivan; Rummeny, Ernst J; Ziegler, Sibylle; Schwaiger, Markus; Nekolla, Stephan G; Beer, Ambros J

    2011-09-01

    In this study, the potential contribution of Dixon-based MR imaging with a rapid low-resolution breath-hold sequence, which is a technique used for MR-based attenuation correction (AC) for MR/positron emission tomography (PET), was evaluated for anatomical correlation of PET-positive lesions on a 3T clinical scanner compared to low-dose CT. This technique is also used in a recently installed fully integrated whole-body MR/PET system. Thirty-five patients routinely scheduled for oncological staging underwent (18)F-fluorodeoxyglucose (FDG) PET/CT and a 2-point Dixon 3-D volumetric interpolated breath-hold examination (VIBE) T1-weighted MR sequence on the same day. Two PET data sets reconstructed using attenuation maps from low-dose CT (PET(AC_CT)) or simulated MR-based segmentation (PET(AC_MR)) were evaluated for focal PET-positive lesions. The certainty for the correlation with anatomical structures was judged in the low-dose CT and Dixon-based MRI on a 4-point scale (0-3). In addition, the standardized uptake values (SUVs) for PET(AC_CT) and PET(AC_MR) were compared. Statistically, no significant difference could be found concerning anatomical localization for all 81 PET-positive lesions in low-dose CT compared to Dixon-based MR (mean 2.51 ± 0.85 and 2.37 ± 0.87, respectively; p = 0.1909). CT tended to be superior for small lymph nodes, bone metastases and pulmonary nodules, while Dixon-based MR proved advantageous for soft tissue pathologies like head/neck tumours and liver metastases. For the PET(AC_CT)- and PET(AC_MR)-based SUVs (mean 6.36 ± 4.47 and 6.31 ± 4.52, respectively) a nearly complete concordance with a highly significant correlation was found (r = 0.9975, p < 0.0001). Dixon-based MR imaging for MR AC allows for anatomical allocation of PET-positive lesions similar to low-dose CT in conventional PET/CT. Thus, this approach appears to be useful for future MR/PET for body regions not fully covered by diagnostic MRI due to potential time constraints.

  13. Pet ownership, dog types and attachment to pets in 9–10 year old children in Liverpool, UK

    PubMed Central

    2013-01-01

    Background Little is known about ethnic, cultural and socioeconomic differences in childhood ownership and attitudes to pets. The objective of this study was to describe the factors associated with living with different pet types, as well as factors that may influence the intensity of relationship or ‘attachment’ that children have to their pet. Data were collected using a survey of 1021 9–10 year old primary school children in a deprived area of the city of Liverpool, UK. Results Dogs were the most common pet owned, most common ‘favourite’ pet, and species most attached to. Twenty-seven percent of dog-owning children (10% of all children surveyed) reported living with a ‘Bull Breed’ dog (which includes Pit Bulls and Staffordshire Bull Terriers), and the most popular dog breed owned was the Staffordshire Bull Terrier. Multivariable regression modelling identified a number of variables associated with ownership of different pets and the strength of attachment to the child’s favourite pet. Girls were more likely to own most pet types, but were no more or less attached to their favourite pet than boys. Children of white ethnicity were more likely to own dogs, rodents and ‘other’ pets but were no more or less attached to their pets than children of non-white ethnicity. Single and youngest children were no more or less likely to own pets than those with younger brothers and sisters, but they showed greater attachment to their pets. Children that owned dogs lived in more deprived areas than those without dogs, and deprivation increased with number of dogs owned. ‘Pit Bull or cross’ and ‘Bull Breed’ dogs were more likely to be found in more deprived areas than other dog types. Non-whites were also more likely to report owning a ‘Pit Bull or cross’ than Whites. Conclusions Gender, ethnicity and socioeconomic status were associated with pet ownership, and sibling status with level of attachment to the pet. These are important to consider when conducting research into the health benefits and risks of the common childhood phenomenon of growing up with pets. PMID:23668544

  14. Pet ownership, dog types and attachment to pets in 9-10 year old children in Liverpool, UK.

    PubMed

    Westgarth, Carri; Boddy, Lynne M; Stratton, Gareth; German, Alexander J; Gaskell, Rosalind M; Coyne, Karen P; Bundred, Peter; McCune, Sandra; Dawson, Susan

    2013-05-13

    Little is known about ethnic, cultural and socioeconomic differences in childhood ownership and attitudes to pets. The objective of this study was to describe the factors associated with living with different pet types, as well as factors that may influence the intensity of relationship or 'attachment' that children have to their pet. Data were collected using a survey of 1021 9-10 year old primary school children in a deprived area of the city of Liverpool, UK. Dogs were the most common pet owned, most common 'favourite' pet, and species most attached to. Twenty-seven percent of dog-owning children (10% of all children surveyed) reported living with a 'Bull Breed' dog (which includes Pit Bulls and Staffordshire Bull Terriers), and the most popular dog breed owned was the Staffordshire Bull Terrier. Multivariable regression modelling identified a number of variables associated with ownership of different pets and the strength of attachment to the child's favourite pet. Girls were more likely to own most pet types, but were no more or less attached to their favourite pet than boys. Children of white ethnicity were more likely to own dogs, rodents and 'other' pets but were no more or less attached to their pets than children of non-white ethnicity. Single and youngest children were no more or less likely to own pets than those with younger brothers and sisters, but they showed greater attachment to their pets. Children that owned dogs lived in more deprived areas than those without dogs, and deprivation increased with number of dogs owned. 'Pit Bull or cross' and 'Bull Breed' dogs were more likely to be found in more deprived areas than other dog types. Non-whites were also more likely to report owning a 'Pit Bull or cross' than Whites. Gender, ethnicity and socioeconomic status were associated with pet ownership, and sibling status with level of attachment to the pet. These are important to consider when conducting research into the health benefits and risks of the common childhood phenomenon of growing up with pets.

  15. The association of pet keeping at home with symptoms in airways, nose and skin among Bulgarian children.

    PubMed

    Naydenov, Kiril; Popov, Todor; Mustakov, Tihomir; Melikov, Arsen; Bornehag, Carl-Gustaf; Sundell, Jan

    2008-12-01

    The role of pet exposure in early childhood for allergy/ asthma later in life is still controversial. Recently it was shown that 'avoidance behaviour' is an important factor for the pet distribution in the population. The aim of the present work is to study the association between self-reported pet keeping at home and symptoms in airways, nose and skin among children 2-7 years of age, in a country where primary prevention strategies regarding allergies are not common. A cross-sectional survey on the association between allergy and asthma symptoms and home environmental factors was conducted in two towns in Bulgaria in spring 2004 (the ALLHOME-1 study). Data for 4479 out of 12982 children was obtained. 21.3% of the parents reported having pets at the time of the questionnaire, and 23.3% for pet keeping at index child's birth. Parents of 3.3% of the children got rid of some of the pets and 10.6% refrained from having pets, due in both cases to allergic illness in the family. Keeping dogs or cats at the time of the survey or during the child's first years was associated with most of the symptoms (aOR 1.1-2.2).

  16. Anthropogenic and Naturally Produced Brominated Phenols in Pet Blood and Pet Food in Japan.

    PubMed

    Mizukawa, Hazuki; Nomiyama, Kei; Nakatsu, Susumu; Yamamoto, Miyuki; Ishizuka, Mayumi; Ikenaka, Yoshinori; Nakayama, Shouta M M; Tanabe, Shinsuke

    2017-10-03

    Present study determined concentrations and residue patterns of bromophenols (BPhs) in whole blood samples of pet cats and pet dogs collected from veterinary hospitals in Japan. BPhs concentrations were higher in cat blood than in dog blood, with statistically insignificant differences (p = 0.07). Among the congeners, 2,4,6-tribromophenol (TBPh) constituted the majority of BPhs (>90%) detected in both species. Analysis of commercial pet food to estimate exposure routes showed that the most abundant congener in all pet food samples was 2,4,6-TBPh, accounting for >99% of total BPhs. This profile is quite similar to the blood samples of the pets, suggesting that diet might be an important exposure route for BPhs in pets. After incubation in polybrominated diphenyl ether (PBDE) mixtures (BDE-47, BDE-99 and BDE-209), 2,4,5-TBPh was found in dog liver microsomes but not in cat liver microsomes, implying species-specific metabolic capacities for PBDEs. Formation of 2,4,5-TBPh occurred by hydroxylation at the 1' carbon atom of the ether bond of BDE-99 is similar to human study reported previously. Hydroxylated PBDEs were not detected in cats or dogs; therefore, diphenyl ether bond cleavage of PBDEs can also be an important metabolic pathway for BPhs formation in cats and dogs.

  17. The diagnostic value of 18F-FDG-PET/CT and MRI in suspected vertebral osteomyelitis - a prospective study.

    PubMed

    Kouijzer, Ilse J E; Scheper, Henk; de Rooy, Jacky W J; Bloem, Johan L; Janssen, Marcel J R; van den Hoven, Leon; Hosman, Allard J F; Visser, Leo G; Oyen, Wim J G; Bleeker-Rovers, Chantal P; de Geus-Oei, Lioe-Fee

    2018-05-01

    The aim of this study was to determine the diagnostic value of 18 F-fluorodeoxyglucose (FDG) positron emission tomography and computed tomography (PET/CT) and magnetic resonance imaging (MRI) in diagnosing vertebral osteomyelitis. From November 2015 until December 2016, 32 patients with suspected vertebral osteomyelitis were prospectively included. All patients underwent both 18 F-FDG-PET/CT and MRI within 48 h. All images were independently reevaluated by two radiologists and two nuclear medicine physicians who were blinded to each others' image interpretation. 18 F-FDG-PET/CT and MRI were compared to the clinical diagnosis according to international guidelines. For 18 F-FDG-PET/CT, sensitivity, specificity, PPV, and NPV in diagnosing vertebral osteomyelitis were 100%, 83.3%, 90.9%, and 100%, respectively. For MRI, sensitivity, specificity, PPV, and NPV were 100%, 91.7%, 95.2%, and 100%, respectively. MRI detected more epidural/spinal abscesses. An important advantage of 18 F-FDG-PET/CT is the detection of metastatic infection (16 patients, 50.0%). 18 F-FDG-PET/CT and MRI are both necessary techniques in diagnosing vertebral osteomyelitis. An important advantage of 18 F-FDG-PET/CT is the visualization of metastatic infection, especially in patients with bacteremia. MRI is more sensitive in detection of small epidural abscesses.

  18. Assessing the kidney function parameters glomerular filtration rate and effective renal plasma flow with dynamic FDG-PET/MRI in healthy subjects.

    PubMed

    Geist, Barbara K; Baltzer, Pascal; Fueger, Barbara; Hamboeck, Martina; Nakuz, Thomas; Papp, Laszlo; Rasul, Sazan; Sundar, Lalith Kumar Shiyam; Hacker, Marcus; Staudenherz, Anton

    2018-05-09

    A method was developed to assess the kidney parameters glomerular filtration rate (GFR) and effective renal plasma flow (ERPF) from 2-deoxy-2-[ 18 F]fluoro-D-glucose (FDG) concentration behavior in kidneys, measured with positron emission tomography (PET) scans. Twenty-four healthy adult subjects prospectively underwent dynamic simultaneous PET/magnetic resonance imaging (MRI) examination. Time activity curves (TACs) were obtained from the dynamic PET series, with the guidance of MR information. Patlak analysis was performed to determine the GFR, and based on integrals, ERPF was calculated. Results were compared to intra-individually obtained reference values determined from venous blood samples. Total kidney GFR and ERPF as estimated by dynamic PET/MRI were highly correlated to their reference values (r = 0.88/p < 0.0001 and r = 0.82/p < 0.0001, respectively) with no significant difference between their means. The study is a proof of concept that GFR and ERPF can be assessed with dynamic FDG PET/MRI scans in healthy kidneys. This has advantages for patients getting a routine scan, where additional examinations for kidney function estimation could be avoided. Further studies are required for transferring this PET/MRI method to PET/CT applications.

  19. Baseline knowledge of potential pet toxins among the US general public.

    PubMed

    Young, Natalie; Royal, Kenneth; Lovee, Bryan; Davidson, Gigi

    2018-05-16

    In 2014, the American Society for the Prevention of Cruelty toAnimals Animal Poison Control Center fielded more than 167,000cases of potential nonhuman animal toxicosis. Concomitantly, thereremain limited free and reputable veterinary toxicology resourcesavailable for companion-animal (pet) caregivers (owners) seekingassistance and advice about potentially harmful exposures inanimals. The objective of this study was to assess pet toxicantknowledge among a representative sample of Americans andgauge the need for additional toxicology resources. The studyinvolved a survey designed to capture participants' ability to identifypotential animal toxicants and what resource they would use ifan accidental toxic ingestion occurred. Participants were ableto correctly identify 52% of potential pet toxins. Women, olderparticipants and participants from the South expressed moreconcern about each potential pet poison. Approximately halfof participants indicated they would consult a veterinarian andwhereas most others indicated they would search the Internet formore information about pet toxicology. The findings suggest moreveterinary poisoning education is needed for pet owners to be ableto accurately distinguish potential pet toxicants from nontoxicants.

  20. The Effect of Adding PET (Polyethylen Terephthalate) Plastic Waste on SCC (Self-Compacting Concrete) to Fresh Concrete Behavior and Mechanical Characteristics

    NASA Astrophysics Data System (ADS)

    Aswatama W, K.; Suyoso, H.; Meyfa U, N.; Tedy, P.

    2018-01-01

    To study the effect PET waste plastics on SCC then PET plastic waste content for SCC is made into 2.5%; 5%; 7.5%; and 10%. As reference concrete is made SCC with 0% PET level. The results on all fresh concrete test items indicate that for all PET waste levels made are meeting the criteria as SCC. The effect of adding PET to fresh concrete behavior on all test items shows that the filling ability and passing ability of concrete work increases with increasing of PET. However, the increase in PET will decrease its mechanical properties. The result of heat test shows that the mechanical properties of concrete (compressive strength, splitting, and elastic modulus) after heating at 250°C temperature has not changed, while at 600°C has significant capacity decline. To clarify the differences between SCC before and after heating, microstructure analysis was done in the form of photo magnification of specimen using SEM (Scanning Electron Microscope).

Top