Sample records for pilot study clean

  1. Final Report of NATO/SPS Pilot Study on Clean Products and Processes (Phase I and II)

    EPA Science Inventory

    Early in 1998 the NATO Committee for Challenges to Modern Society (SPS) (Science for Peace and Security) approved the Pilot Study on Clean Products and Processes for an initial period of five years. The pilot was to provide a forum for member country representatives to discuss t...

  2. NATO/CCMS PILOT STUDY ON CLEAN PRODUCTS & PROCESSES

    EPA Science Inventory

    Led by the United States, represented by the U.S. Environmental Protection Agency's (EPA's) National Risk Management Research Laboratory, the Pilot Study on Clean Products and Processes was instituted to create an international forum where current trends, developments, and expert...

  3. RECYCLING A NONIONIC AQUEOUS-BASED METAL-CLEANING SOLUTION WITH A CERAMIC MEMBRANE: PILOT SCALE EVALUATION

    EPA Science Inventory

    The effectiveness of a zirconium dioxide (ZrO2) membrane filter was evaluated for recycling a nonionic aqueous metal cleaning bath under real-world conditions. The pilot-scale study consisted of four 7- to 16-day filtration runs, each processed a portion of the cleaning bath duri...

  4. NATO/CCMS PILOT STUDY - CLEAN PRODUCTS AND PROCESSES (PHASE I) 2000 ANNUAL REPORT, NUMBER 242

    EPA Science Inventory

    This annual report presents the proceedings of the Third Annual NATO/CCMS pilot study meeting in Copenhagen, Denmark. Guest speakers focused on efforts in the area of research of clean products and processes, life cycle analysis, computer tools and pollution prevention.

  5. NATO CCMS PILOT STUDY ON CLEAN PRODUCTS AND PROCESSES -(PHASE I) - 2002 ANNUAL REPORT

    EPA Science Inventory

    The annual report summarizes the activities of the NATO CCMS Pilot Study on clean products and processes for 2002, including the proceedings of the 2002 annual meeting held in Vilnius, Lithuania. The report presents a wealth of information on cleaner production activities in ove...

  6. NATO/CCMS PILOT STUDY - CLEAN PRODUCTS AND PROCESSES

    EPA Science Inventory

    The proposed objective of the NATO/CCMS Pilot on clean products and processes is to facilitate further gains in pollution prevention, waste minimization, and design for the environment. It is anticipated that the free exchange of knowledge, experience, data, and models will fost...

  7. NATO/CCMS PILOT STUDY CLEAN PRODUCTS AND PROCESSES (PHASE II) 2003 ANNUAL REPORT

    EPA Science Inventory

    The 6th annual meeting of the NATO CCMS Pilot Study, Clean Products and Processes, was held in Cetraro, Italy, from May 11 to 15, 2003. This was also the first meeting of its Phase II study. 24 country representatives attended this meeting. This meeting was very ably run by th...

  8. RESULTS OF A PILOT FIELD STUDY TO EVALUATE THE EFFECTIVENESS OF CLEANING RESIDENTIAL HEATING AND AIR-CONDITIONING SYSTEMS AND THE IMPACT ON INDOOR AIR QUALITY AND SYSTEM PERFORMANCE

    EPA Science Inventory

    The report discusses and gives results of a pilot field study to evaluate the effectiveness of air duct cleaning (ADC) as a source removal technique in residential heating and air-conditioning (HAC) systems and its impact on airborne particle, fiber, and bioaerosol concentrations...

  9. Cleaning Products Pilot Project

    EPA Pesticide Factsheets

    This 1997 case study documents a three-year effort to identify and compare environmentally preferable commercial cleaning products and to implement the Environmentally Preferable Purchasing Program (EPP).

  10. Investigation of biosecurity risks associated with the feed delivery: A pilot study

    PubMed Central

    Bottoms, Kate; Dewey, Cate; Richardson, Karen; Poljak, Zvonimir

    2015-01-01

    This study explored potential biosecurity issues related to the delivery of feed to commercial farms. A pilot study was conducted to collect information about the day-to-day feed delivery, including biosecurity concerns at the level of the feed truck, the driver, and the farm. In addition, a reusable rubber boot was tested in an effort to increase the proportion of farms at which truck drivers wore clean footwear, and to explore an alternative to the standard plastic disposable boots that may be unsafe in winter conditions. Most farms did well in terms of proper dead-stock management and keeping the farm lane and feed bin areas clean. The provision of reusable rubber boots significantly increased the proportion of deliveries in which the driver wore clean footwear. PMID:25969585

  11. Investigation of biosecurity risks associated with the feed delivery: A pilot study.

    PubMed

    Bottoms, Kate; Dewey, Cate; Richardson, Karen; Poljak, Zvonimir

    2015-05-01

    This study explored potential biosecurity issues related to the delivery of feed to commercial farms. A pilot study was conducted to collect information about the day-to-day feed delivery, including biosecurity concerns at the level of the feed truck, the driver, and the farm. In addition, a reusable rubber boot was tested in an effort to increase the proportion of farms at which truck drivers wore clean footwear, and to explore an alternative to the standard plastic disposable boots that may be unsafe in winter conditions. Most farms did well in terms of proper dead-stock management and keeping the farm lane and feed bin areas clean. The provision of reusable rubber boots significantly increased the proportion of deliveries in which the driver wore clean footwear.

  12. Examining factors that influence the effectiveness of cleaning antineoplastic drugs from drug preparation surfaces: a pilot study.

    PubMed

    Hon, Chun-Yip; Chua, Prescillia Ps; Danyluk, Quinn; Astrakianakis, George

    2014-06-01

    Occupational exposure to antineoplastic drugs has been documented to result in various adverse health effects. Despite the implementation of control measures to minimize exposure, detectable levels of drug residual are still found on hospital work surfaces. Cleaning these surfaces is considered as one means to minimize the exposure potential. However, there are no consistent guiding principles related to cleaning of contaminated surfaces resulting in hospitals to adopt varying practices. As such, this pilot study sought to evaluate current cleaning protocols and identify those factors that were most effective in reducing contamination on drug preparation surfaces. Three cleaning variables were examined: (1) type of cleaning agent (CaviCide®, Phenokil II™, bleach and chlorhexidine), (2) application method of cleaning agent (directly onto surface or indirectly onto a wipe) and (3) use of isopropyl alcohol after cleaning agent application. Known concentrations of antineoplastic drugs (either methotrexate or cyclophosphamide) were placed on a stainless steel swatch and then, systematically, each of the three cleaning variables was tested. Surface wipes were collected and quantified using high-performance liquid chromatography-tandem mass spectrometry to determine the percent residual of drug remaining (with 100% being complete elimination of the drug). No one single cleaning agent proved to be effective in completely eliminating all drug contamination. The method of application had minimal effect on the amount of drug residual. In general, application of isopropyl alcohol after the use of cleaning agent further reduced the level of drug contamination although measureable levels of drug were still found in some cases.

  13. Examination of staphylococcal stethoscope contamination in the emergency department (pilot) study (EXSSCITED pilot study).

    PubMed

    Tang, Patrick H P; Worster, Andrew; Srigley, Jocelyn A; Main, Cheryl L

    2011-07-01

    The objective of this study was to determine the prevalence of Staphylococcus-contaminated stethoscopes belonging to emergency department (ED) staff and to identify the proportion of these that were Staphylococcus aureus or methicillin-resistant Staphylococcus aureus (MRSA). We conducted a prospective observational cohort study of bacterial cultures from 100 ED staff members' stethoscopes at three EDs. Study participants were asked to complete a questionnaire. Fifty-four specimens grew coagulase-negative staphylococci and one grew methicillin-susceptible S. aureus. No MRSA was cultured. Only 8% of participants, all of whom were nurses, reported cleaning their stethoscope before or after each patient assessment. Alcohol-based wipes were most commonly used to clean stethoscopes. A lack of time, being too busy, and forgetfulness were the most frequently reported reasons for not cleaning the stethoscope in the ED. This study indicates that although stethoscope contamination rates in these EDs are high, the prevalence of S. aureus or MRSA on stethoscopes is low.

  14. Long term performance of membranes in an anaerobic membrane bioreactor treating municipal wastewater.

    PubMed

    Dong, Qirong; Parker, Wayne; Dagnew, Martha

    2016-02-01

    The long term impact of SRT (100-40 days) and recovery cleaning on membrane performance of an AnMBR treating authentic municipal wastewater in a large pilot plant was assessed. Successful operation of the pilot plant at a flux of 17 LMH was maintained for a period of 536 days during which the longest period of operation without recovery cleaning or membrane replacement was 178 days. Lower SRT (40 days) reduced the fouling propensity of the mixed liquor in terms of TSS concentration and the dewaterability indicators including colloidal COD (cCOD) concentration and capillary suction time (CST). Critical fluxes ranged from 21 to 23 LMH to 25-27 LMH for SRTs of 70 and 40 days respectively and this was consistent with the reduced concentrations of TSS and improved dewaterability under the latter conditions. Recovery cleaning was found to result in substantial reduction of resistance as indicated by both pilot plant operation and clean water flux tests. The long-term fouling rate was observed to be higher with cleaned membranes as compared to virgin membranes. The lower membrane fouling with virgin membranes suggested that accumulation of foulants, which were resistant to cleaning, caused the higher fouling rates for the cleaned membranes. Copyright © 2015 Elsevier Ltd. All rights reserved.

  15. PICKLEX AS A NON-POLLUTING METAL SURFACE FINISHING PRETREATMENT AND PRETREATMENT/CONVERSION COATING

    EPA Science Inventory

    The effectiveness of a zirconium dioxide (ZrO2) membrane filter was evaluated for recycling a nonionic aqueous metal cleaning bath under real world conditions. The pilot-scale study consisted of four 7-to16-day filtration runs, each processed a portion of the cleaning bath during...

  16. Development of clean coal and clean soil technologies using advanced agglomeration techniques

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ignasiak, B.; Ignasiak, T.; Szymocha, K.

    1990-01-01

    Three major topics are discussed in this report: (1) Upgrading of Low Rank Coals by the Agflotherm Process. Test data, procedures, equipment, etc., are described for co-upgrading of subbituminous coals and heavy oil; (2) Upgrading of Bituminous Coals by the Agflotherm Process. Experimental procedures and data, bench and pilot scale equipments, etc., for beneficiating bituminous coals are described; (3) Soil Clean-up and Hydrocarbon Waste Treatment Process. Batch and pilot plant tests are described for soil contaminated by tar refuse from manufactured gas plant sites. (VC)

  17. Evaluating and operationalizing an environmental auditing program: a pilot study.

    PubMed

    Gordon, Laura; Bruce, Natalie; Suh, Kathryn N; Roth, Virginia

    2014-07-01

    Environmental auditing is an important tool to ensure consistent and effective cleaning. Our pilot study compared an alcohol-based fluorescent marking product and an adenosine-5'-triphosphate bioluminescence product for use in an environmental auditing program to determine which product was more practical and acceptable to users. Both products were tested on 15 preselected high touch objects in randomly selected patient rooms, following regular daily cleaning. A room was considered a "pass" if ≥80% of surfaces were adequately cleaned as defined by manufacturers' guidelines. A qualitative survey assessed user preference and operational considerations. Using fluorescent marking, 9 of 37 patient rooms evaluated (24%) were considered a "pass" after daily cleaning. Using adenosine-5'-triphosphate bioluminescence, 21 of 37 patient rooms passed (57%). There was great variability in results between different high touch objects. Eighty percent of users preferred the alcohol-based fluorescent marking product because it provided an effective visual aid to coach staff on proper cleaning techniques and allowed simple and consistent application. Environmental auditing using translucent, alcohol-based fluorescent marking best met the requirements of our organization. Our results reinforce the importance of involving a multidisciplinary team in evaluating and operationalizing an environmental auditing program. Copyright © 2014 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Mosby, Inc. All rights reserved.

  18. NREL to Collaborate with Small Clean Energy Businesses as Part of DOE Pilot

    Science.gov Websites

    help the first group of small clean energy businesses advance their products under the Small Business Vouchers (SBV) pilot launched last July by DOE. NREL is one of nine national laboratories participating in . Midwest Energy Group (MEG) of Illinois will use NREL's fuel cell test facilities to assess the long-term

  19. Optimization of the cleaning process on a pilot filtration setup for waste water treatment accompanied by flow visualization

    NASA Astrophysics Data System (ADS)

    Bílek, Petr; Hrůza, Jakub

    2018-06-01

    This paper deals with an optimization of the cleaning process on a liquid flat-sheet filter accompanied by visualization of the inlet side of a filter. The cleaning process has a crucial impact on the hydrodynamic properties of flat-sheet filters. Cleaning methods avoid depositing of particles on the filter surface and forming a filtration cake. Visualization significantly helps to optimize the cleaning methods, because it brings new overall view on the filtration process in time. The optical method, described in the article, enables to see flow behaviour in a thin laser sheet on the inlet side of a tested filter during the cleaning process. Visualization is a strong tool for investigation of the processes on filters in details and it is also possible to determine concentration of particles after an image analysis. The impact of air flow rate, inverse pressure drop and duration on the cleaning mechanism is investigated in the article. Images of the cleaning process are compared to the hydrodynamic data. The tests are carried out on a pilot filtration setup for waste water treatment.

  20. 46 CFR 97.90-1 - Pilot boarding operation.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 4 2011-10-01 2011-10-01 false Pilot boarding operation. 97.90-1 Section 97.90-1... OPERATIONS Pilot Boarding Operations § 97.90-1 Pilot boarding operation. (a) The master shall ensure that pilot boarding equipment is maintained as follows: (1) The equipment must be kept clean and in good...

  1. 46 CFR 97.90-1 - Pilot boarding operation.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Pilot boarding operation. 97.90-1 Section 97.90-1... OPERATIONS Pilot Boarding Operations § 97.90-1 Pilot boarding operation. (a) The master shall ensure that pilot boarding equipment is maintained as follows: (1) The equipment must be kept clean and in good...

  2. General Aviation Citizen Science Pilot Study to Help Tackle Remote Sensing of Harmful Algal Blooms (HABs)

    NASA Astrophysics Data System (ADS)

    Ansari, R.

    2017-12-01

    Aerial remote sensing conducted by volunteer pilots acting as citizen scientists is providing high-quality data to help understand reasons behind outbreaks of toxic algal blooms in nation's waterways and coastlines. The toxic water can be detrimental to national economy, human health, clean drinking water, fishing industry, and water sports. We will show how general aviation pilots around the country are contributing to this NASA citizen science initiative.

  3. Pilot-scale continuous ultrasonic cleaning equipment reduces Listeria monocytogenes levels on conveyor belts.

    PubMed

    Tolvanen, Riina; Lundén, Janne; Hörman, Ari; Korkeala, Hannu

    2009-02-01

    Ultrasonic cleaning of a conveyor belt was studied by building a pilot-scale conveyor with an ultrasonic cleaning bath. A piece of the stainless steel conveyor belt was contaminated with meat-based soil and Listeria monocytogenes strains (V1, V3, and B9) and incubated for 72 h to allow bacteria to attach to the conveyor belt surfaces. The effect of ultrasound with a potassium hydroxide-based cleaning detergent was determined by using the cleaning bath at 45 and 50 degrees C for 30 s with and without ultrasound. The detachment of L. monocytogenes from the conveyor belt caused by the ultrasonic treatment was significantly greater at 45 degrees C (independent samples t test, P < 0.001) and at 50 degrees C (independent samples t test, P = 0.04) than without ultrasound. Ultrasonic cleaning efficiency was tested with different cleaning durations (10, 15, 20, and 30 s) and temperatures (30, 45, and 50 degrees C). The differences in the log reduction between cleaning treatments were analyzed by analysis of variance with Tamhane's T2 posthoc test using SPSS (Chicago, IL). The lengthening of the treatment time from 10 to 30 s did not significantly increase the detachment of L. monocytogenes (ANOVA 0.633). At 30 degrees C and at the longest time tested (30 s), the treatment reduced L. monocytogenes counts by only 2.68 log units. However, an increase in temperature from 30 to 50 degrees C improved the effect of the ultrasonic treatment significantly (P < 0.01). Ultrasonic cleaning for 10 s at 50 degrees C reduced L. monocytogenes counts by more than 5 log units. These results indicate that ultrasonic cleaning of a conveyor belt is effective even with short treatment times.

  4. PHASE I PILOT AIR CONVEYANCE SYSTEM DESIGN, CLEANING, AND CHARACTERIZATION

    EPA Science Inventory

    The report gives results of a project to develop and refine surface and airborne contamination
    measurement techniques that can be used to evaluate air conveyance system (ACS) cleaning.
    (NOTE: ACS cleaning is advertized to homeowners as a service having a number of benefits...

  5. Quantitative assessment of airborne exposures generated during common cleaning tasks: a pilot study

    PubMed Central

    2010-01-01

    Background A growing body of epidemiologic evidence suggests an association between exposure to cleaning products with asthma and other respiratory disorders. Thus far, these studies have conducted only limited quantitative exposure assessments. Exposures from cleaning products are difficult to measure because they are complex mixtures of chemicals with a range of physicochemical properties, thus requiring multiple measurement techniques. We conducted a pilot exposure assessment study to identify methods for assessing short term, task-based airborne exposures and to quantitatively evaluate airborne exposures associated with cleaning tasks simulated under controlled work environment conditions. Methods Sink, mirror, and toilet bowl cleaning tasks were simulated in a large ventilated bathroom and a small unventilated bathroom using a general purpose, a glass, and a bathroom cleaner. All tasks were performed for 10 minutes. Airborne total volatile organic compounds (TVOC) generated during the tasks were measured using a direct reading instrument (DRI) with a photo ionization detector. Volatile organic ingredients of the cleaning mixtures were assessed utilizing an integrated sampling and analytic method, EPA TO-17. Ammonia air concentrations were also measured with an electrochemical sensor embedded in the DRI. Results Average TVOC concentrations calculated for 10 minute tasks ranged 0.02 - 6.49 ppm and the highest peak concentrations observed ranged 0.14-11 ppm. TVOC time concentration profiles indicated that exposures above background level remained present for about 20 minutes after cessation of the tasks. Among several targeted VOC compounds from cleaning mixtures, only 2-BE was detectable with the EPA method. The ten minute average 2- BE concentrations ranged 0.30 -21 ppm between tasks. The DRI underestimated 2-BE exposures compared to the results from the integrated method. The highest concentration of ammonia of 2.8 ppm occurred during mirror cleaning. Conclusions Our results indicate that airborne exposures from short-term cleaning tasks can remain in the air even after tasks' cessation, suggesting potential exposures to anyone entering the room shortly after cleaning. Additionally, 2-BE concentrations from cleaning could approach occupational exposure limits and warrant further investigation. Measurement methods applied in this study can be useful for workplace assessment of airborne exposures during cleaning, if the limitations identified here are addressed. PMID:21118559

  6. Mechanical vs. manual cleaning of hospital beds: a prospective intervention study.

    PubMed

    Hopman, J; Nillesen, M; de Both, E; Witte, J; Teerenstra, S; Hulscher, M; Voss, A

    2015-06-01

    Cleaning regimens for hospital beds were evaluated in the context of a rising prevalence of highly resistant micro-organisms and increasing financial pressure on healthcare systems. Dutch hospitals have to choose between standardized, mechanical bed-washers advised in national guidance and manual cleaning. To evaluate the quality of mechanical and manual bed-cleaning regimens. The multi-faceted analysis of bed-cleaning regimens consisted of three steps. In Step 1, the training of the domestic service team was evaluated. In Step 2, the cleaning quality of manual and mechanical regimens was assessed. Soiled beds, obtained at random, from different departments were evaluated using microbiological analysis (N = 40) and ATP (N = 20). ATP and microbiological contamination were measured in five predetermined locations on all beds. In Step 3, manual cleaning was introduced over a two-month pilot study at the surgical short-stay unit, and beds from other departments were processed according to the 'gold standard' mechanical cleaning. ATP levels were evaluated in three locations on 300 beds after cleaning. Training was found to improve the quality of cleaning significantly. Mechanical cleaning resulted in significantly lower ATP levels than manual cleaning. Mechanical cleaning shows less variation and results in consistently lower ATP levels than manual cleaning. Copyright © 2015 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  7. Reducing absenteeism in hospital cleaning staff: pilot of a theory based intervention.

    PubMed

    Michie, S; Wren, B; Williams, S

    2004-04-01

    To develop, pilot, and evaluate a workplace intervention to reduce sickness absence, based on a demand-control-support model of job strain. Changes in the working arrangements of hospital cleaning staff were introduced with the aim of increasing their control over work and the support received at work. The study design was quasi-experimental, with 221 cleaning staff in the intervention group and 91 catering staff in the control group. The dependent variable was the difference in percentage monthly sickness absence between the 12 months preceding and following the intervention. Differences in sickness absence between staff groups for each month after the intervention were compared with differences between staff groups for the equivalent month one year prior to it. There was a significant reduction in the difference in sickness absence rates between the intervention and control group of 2.3% in the six months after the intervention, compared to the six months before. The difference was not maintained at 12 months. These results suggest that a workplace intervention aimed at increasing control and support at work has a small effect on reducing sickness absence among hospital cleaning staff in the short term. Future research should seek to replicate this effect in larger, experimental studies, analyse postulated mediators of such theory based interventions, and develop interventions that maintain improvement.

  8. Principles of an enhanced MBR-process with mechanical cleaning.

    PubMed

    Rosenberger, S; Helmus, F P; Krause, S; Bareth, A; Meyer-Blumenroth, U

    2011-01-01

    Up to date, different physical and chemical cleaning protocols are necessary to limit membrane fouling in membrane bioreactors. This paper deals with a mechanical cleaning process, which aims at the avoidance of hypochlorite and other critical chemicals in MBR with submerged flat sheet modules. The process basically consists of the addition of plastic particles into the loop circulation within submerged membrane modules. Investigations of two pilot plants are presented: Pilot plant 1 is equipped with a 10 m(2) membrane module and operated with a translucent model suspension; pilot plant 2 is equipped with four 50 m(2) membrane modules and operated with pretreated sewage. Results of pilot plant 1 show that the establishment of a fluidised bed with regular particle distribution is possible for a variety of particles. Particles with maximum densities of 1.05 g/cm(3) and between 3 and 5 mm diameter form a stable fluidised bed almost regardless of activated sludge concentration, viscosity and reactor geometry. Particles with densities between 1.05 g/cm(3) and 1.2 g/cm(3) form a stable fluidised bed, if the velocity at the reactor bottom is sufficiently high. Activities within pilot plant 2 focused on plant optimisation and the development of an adequate particle retention system.

  9. 40 CFR 88.205-94 - California Pilot Test Program Credits Program.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Program to meet the clean-fuel vehicle sales requirements through the use of credits. Participation in... be generated by any of the following means: (i) Sale of qualifying clean-fuel vehicles earlier than... requirements of paragraph (g) of this section. (ii) Sale of a greater number of qualifying clean-fuel vehicles...

  10. Self-Scrubbing Coal -- an integrated approach to clean air

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Harrison, K.E.

    1997-12-31

    Carefree Coal is coal cleaned in a proprietary dense-media cyclone circuit, using ultrafine magnetite slurries, to remove noncombustible material, including up to 90% of the pyritic sulfur. Deep cleaning alone, however, cannot produce a compliance fuel from coals with high organic sulfur contents. In these cases, Self-Scrubbing Coal will be produced. Self-Scrubbing Coal is produced in the same manner as Carefree Coal except that the finest fraction of product from the cleaning circuit is mixed with limestone-based additives and briquetted. The reduced ash content of the deeply-cleaned coal will permit the addition of relatively large amounts of sorbent without exceedingmore » boiler ash specifications or overloading electrostatic precipitators. This additive reacts with sulfur dioxide (SO{sub 2}) during combustion of the coal to remove most of the remaining sulfur. Overall, sulfur reductions in the range of 80--90% are achieved. After nearly 5 years of research and development of a proprietary coal cleaning technology coupled with pilot-scale validation studies of this technology and pilot-scale combustion testing of Self-Scrubbing Coal, Custom Coals Corporation organized a team of experts to prepare a proposal in response to DOE`s Round IV Program Opportunity Notice for its Clean Coal Technology Program under Public Law 101-121 and Public Law 101-512. The main objective of the demonstration project is the production of a coal fuel that will result in up to 90% reduction in sulfur emissions from coal-fired boilers at a cost competitive advantage over other technologies designed to accomplish the same sulfur emissions and over naturally occurring low sulfur coals.« less

  11. New Jersey: Clean Air Communities (A Former EPA CARE Project)

    EPA Pesticide Factsheets

    Clean Air Communities (CAC) is the recipient of a Level II CARE cooperative agreement to implement recommendations by the state’s Environmental Justice Task Force and the Air Toxics Pilot Project to reduce environmental risks.

  12. NATO COMMITTEE ON THE CHALLENGES TO MODERN SOCIETY PILOT STUDY: CLEAN PRODUCTS AND PROCESSES

    EPA Science Inventory

    Promote cooperation for improving the common pollution landscape by stimulating cross-national dialogues and collaboration. Share knowledge on the methods, tools, and technologies for making cleaner products and processes possible.

  13. AQUEOUS CLEANING OF PRINTED CIRCUIT BOARD STENCILS

    EPA Science Inventory

    The USEPA through NRMRL has partnered with the California Dept. of Toxic Substance Control under an ETV Pilot Project to verigy polllution prevention, recycling and waste treatment technologies. One of the projects selected for verification was the ultrasonic aqueous cleaning tec...

  14. Study of slow sand filtration with backwash and the influence of the filter media on the filter recovery and cleaning.

    PubMed

    de Souza, Fernando Hymnô; Pizzolatti, Bruno Segalla; Schöntag, Juliana Marques; Sens, Maurício Luiz

    2016-01-01

    Slow sand filters are considered as a great alternative for supplying drinking water in rural and/or isolated areas where raw water that is treatable with this technique is available. Some studies used backwashing as an alternative for cleaning the slow sand filter with the goal of applying the technology in small communities, since filters that supply water to a small number of people do not require much space. In this study the influence of the effective diameter on water quality in the filters and cleaning system was evaluated. A pilot system with six filters was built: three filters were conventionally cleaned by scraping and the other three were cleaned by backwashing, each with a different effective diameter of filter medium. Most filters had an average turbidity of less than 1.0 NTU, the turbidity required at the output of the filters by the Brazilian Ministry of Health Ordinance. In the study, the filters cleaned by scraping with smaller-diameter filter beds effectively filtered water better but had worse effective production. The opposite occurs in the case of backwashed filters.

  15. Effect of mouth cleaning with hinokitiol-containing gel on oral malodor: a randomized, open-label pilot study.

    PubMed

    Iha, Kosaku; Suzuki, Nao; Yoneda, Masahiro; Takeshita, Toru; Hirofuji, Takao

    2013-10-01

    The aim of the study was to evaluate the effect of mouth cleaning with hinokitiol-containing gel on oral malodor. An open-label, randomized, controlled trial was conducted to assess oral malodor and clinical parameters related to oral malodor before and after mouth cleaning with hinokitiol-containing gel (n = 9) or with gel not including hinokitiol (n = 9). Mouth cleaning included the teeth, gingiva, and tongue and was carried out 3 times per day for 4 weeks. Organoleptic test (OLT) scores (P = .021), levels of hydrogen sulfide (P = .008) and methyl mercaptan (P = .020), frequency of bleeding on probing, average probing pocket depth, and plaque index significantly improved in the group using hinokitiol. In contrast, only the OLT score (P = .031) significantly improved in the control group after the treatment regimen. Mouth cleaning with hinokitiol-containing gel may be effective for reduction of oral malodor. Copyright © 2013 Elsevier Inc. All rights reserved.

  16. Sidestream superoxygenation for wastewater treatment: Oxygen transfer in clean water and mixed liquor.

    PubMed

    Barreto, Carlos M; Ochoa, Ivania M; Garcia, Hector A; Hooijmans, Christine M; Livingston, Dennis; Herrera, Aridai; Brdjanovic, Damir

    2018-08-01

    The performance of a pilot-scale superoxygenation system was evaluated in clean water and mixed liquor. A mass balance was applied over the pilot-scale system to determine the overall oxygen mass transfer rate coefficient (K L a, h -1 ), the standard oxygen transfer rate (SOTR, kg O 2 d -1 ), and the standard oxygen transfer efficiency (SOTE, %). Additionally, the alpha factor (α) was determined at a mixed liquor suspend solids (MLSS) concentration of approximately 5 g L -1 . SOTEs of nearly 100% were obtained in clean water and mixed liquor. The results showed that at higher oxygen flowrates, higher transfer rates could be achieved; this however, at expenses of the transfer efficiency. As expected, lower transfer efficiencies were observed in mixed liquor compared to clean water. Alpha factors varied between 0.6 and 1.0. However, values of approximately 1.0 can be obtained in all cases by fine tuning the oxygen flowrate delivered to the system. Copyright © 2018 Elsevier Ltd. All rights reserved.

  17. 75 FR 54146 - Science Advisory Board Staff Office; Notification of a Public Meeting of the Clean Air Scientific...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-09-03

    ... guidance document, and pilot monitoring study can be directed to Mr. Nealson Watkins at 919-541-5522 or watkins[email protected] . Availability of Meeting Materials: The EPA draft guidance documents are posted...

  18. Pilot Plant Program for the AED Advanced Coal Cleaning System. Phase II. Interim final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1980-08-01

    Advanced Energy Dynamics, Inc. (AED), has developed a proprietary coal cleaning process which employs a combination of ionization and electrostatic separation to remove both sulfur and ash from dry pulverized coal. The Ohio Department of Energy sponsored the first part of a program to evaluate, develop, and demonstrate the process in a continuous-flow pilot plant. Various coals used by Ohio electric utilities were characterized and classified, and sulfur reduction, ash reduction and Btu recovery were measured. Sulfur removal in various coals ranged from 33 to 68% (on a Btu basis). Ash removal ranged from 17 to 59% (on a Btumore » basis). Ash removal of particles greater than 53 microns ranged from 46 to 88%. Btu recovery ranged from 90 to 97%. These results, especially the large percentage removal of ash particles greater than 53 microns, suggest that the AED system can contribute materially to improved boiler performance and availability. The study indicated the following potential areas for commercial utilization of the AED process: installation between the pulverizer and boiler of conventional coal-fired power utilities; reclamation of fine coal refuse; dry coal cleaning to supplement, and, if necessary, to take the place of conventional coal cleaning; upgrading coal used in: (1) coal-oil mixtures, (2) gasification and liquefaction processes designed to handle pulverized coal; and (3) blast furnaces for making steel, as a fuel supplement to the coke. Partial cleaning of coking coal blends during preheating may also prove economically attractive. Numerous other industrial processes which use pulverized coal such as the production of activated carbon and direct reduction of iron ore may also benefit from the use of AED coal cleaning.« less

  19. Does Flooring Substrate Impact Kennel and Dog Cleanliness in Commercial Breeding Facilities?

    PubMed Central

    Stella, Judith; Hurt, Moriah; Bauer, Amy; Croney, Candace

    2018-01-01

    Simple Summary It is important to understand how the flooring substrate used in dog housing impacts dog health and well-being. Aspects to consider include paw, elbow, and hock health, the cleanliness of the dog, and the ability of the floors to be cleaned easily and thoroughly. This pilot study assessed the health and cleanliness of 118 dogs housed on three different types of flooring commonly found in commercial breeding kennels. No serious paw, elbow, or hock problems were identified. Thirty-one percent or fewer kennels at each facility were found to have fecal contamination after routine cleaning and the majority of dogs were clean. These findings indicate that a well-managed kennel can maintain clean, healthy dogs on different types of flooring substrates. Abstract Evaluation of kennel flooring surfaces is needed to understand their impacts on dog health and well-being. This pilot study aimed to characterize aspects of physical health, kennel cleanliness, and dog body cleanliness on flooring types common in US breeding kennels. Subjects were 118 adult dogs housed on diamond-coated expanded metal (DCEM), polypropylene (POLY), or concrete (CON) flooring at five commercial breeding facilities in Indiana, U.S. Body condition, paw, elbow, and hock health scores were recorded. Each indoor kennel and dog was visually assessed for cleanliness. Kennels were swabbed immediately after cleaning with electrostatic dry cloths and cultured for Escherichia coli. Descriptive statistics were used for analysis. Mean body condition score (BCS), kennel and dog cleanliness scores were all near ideal (3, 1.15, and 1.04, respectively). Thirty-one percent or fewer kennels at each facility were culture-positive for E. coli after cleaning. No serious paw, elbow, or hock problems were identified. Overall, the findings indicate that with appropriate management and regular access to additional surfaces, dog foot health, cleanliness, and kennel cleanliness can be maintained on the flooring types investigated. PMID:29690514

  20. NATO CCMS PILOT STUDY - CLEAN PRODUCTS AND PROCESSES, NATIONAL RISK MANAGEMENT RESEARCH LABORATORY

    EPA Science Inventory

    The Committee on the Challenges to Modern Society (CCMS) was established by the North Atlantic Treaty Organization (NATO) in 1969. The mission of CCMS is to develop meaningful programs to share information among countries on important environmental and societal issues that comple...

  1. Comparison of Decontamination Efficacy of Cleaning Solutions on a Biological Safety Cabinet Workbench Contaminated by Cyclophosphamide

    PubMed Central

    Adé, Apolline; Chauchat, Laure; Frève, Johann-François Ouellette; Gagné, Sébastien; Caron, Nicolas; Bussières, Jean-François

    2017-01-01

    Background Several studies have compared cleaning procedures for decontaminating surfaces exposed to antineoplastic drugs. All of the cleaning products tested were successful in reducing most of the antineoplastic drug quantities spilled on surfaces, but none of them completely removed residual traces. Objective To assess the efficacy of various cleaning solutions for decontaminating a biological safety cabinet workbench exposed to a defined amount of cyclophosphamide. Methods In this pilot study, specific areas of 2 biological safety cabinets (class II, type B2) were deliberately contaminated with a defined quantity of cyclophosphamide (10 μg or 107 pg). Three cleaning solutions were tested: quaternary ammonium, sodium hypochlorite 0.02%, and sodium hypochlorite 2%. After cleaning, the cyclophosphamide remaining on the areas was quantified by wipe sampling. Each cleaning solution was tested 3 times, with cleaning and wipe sampling being performed 5 times for each test. Results A total of 57 wipe samples were collected and analyzed. The average recovery efficiency was 121.690% (standard deviation 5.058%). The decontamination efficacy increased with the number of successive cleaning sessions: from 98.710% after session 1 to 99.997% after session 5 for quaternary ammonium; from 97.027% to 99.997% for sodium hypochlorite 0.02%; and from 98.008% to 100% for sodium hypochlorite 2%. Five additional cleaning sessions performed after the main study (with detergent and sodium hypochlorite 2%) were effective to complete the decontamination, leaving no detectable traces of the drug. Conclusions All of the cleaning solutions reduced contamination of biological safety cabinet workbenches exposed to a defined amount of cyclophosphamide. Quaternary ammonium and sodium hypochlorite (0.02% and 2%) had mean efficacy greater than 97% for removal of the initial quantity of the drug (107 pg) after the first cleaning session. When sodium hypochlorite 2% was used, fewer cleaning sessions were required to complete decontamination. Further studies should be conducted to identify optimal cleaning strategies to fully eliminate traces of hazardous drugs. PMID:29298999

  2. STS-65 Pilot Halsell cleans window on the aft flight deck of Columbia, OV-102

    NASA Technical Reports Server (NTRS)

    1994-01-01

    On the aft flight deck of Columbia, Orbiter Vehicle (OV) 102, STS-65 Pilot James D. Halsell, Jr cleans off overhead window W8. Mission Specialist (MS) Carl E. Walz looks on (photo's edge). A plastic toy dinosaur, velcroed in front of W9, also appears to be watching the housekeeping activity. A variety of onboard equipment including procedural checklists, a spotmeter, a handheld microphone, and charts are seen in the view. The two shared over fourteen days in Earth orbit with four other NASA astronauts and a Japanese payload specialist in support of the second International Microgravity Laboratory (IML-2) mission.

  3. PILOT IN SITU CAPPING PROJECT FOR PALOS VERDES SHELF CONTAMINATED SEDIMENTS

    EPA Science Inventory

    The Palos Verdes Shelf Pilot Capping Project will evaluate the short-term results of capping the DDT- and PCB-contaminated sediment with clean sediment. It will also determine how these results are affected by variables such as cap material, placement method and water depth. The ...

  4. Use of a Modern Polymerization Pilot-Plant for Undergraduate Control Projects.

    ERIC Educational Resources Information Center

    Mendoza-Bustos, S. A.; And Others

    1991-01-01

    Described is a project where students gain experience in handling large volumes of hazardous materials, process start up and shut down, equipment failures, operational variations, scaling up, equipment cleaning, and run-time scheduling while working in a modern pilot plant. Included are the system design, experimental procedures, and results. (KR)

  5. SIMPLE ANALYTICAL MODEL FOR HEAT FLOW IN FRACTURES-APPLICATION TO STEAM ENHANCED REMEDIATION CONDUCTED IN FRACTURED ROCK

    EPA Science Inventory

    Remediation of fractured rock sites contaminated by non-aqueous phase liquids has long been recognized as the most difficult undertaking of any site clean-up. Recent pilot studies conducted at the Edwards Air Force Base in California and the former Loring Air Force Base in Maine ...

  6. SIMPLE ANALYTICAL MODEL FOR HEAT FLOW IN FRACTURES - APPLICATION TO STEAM ENHANCED REMEDIATION CONDUCTED IN FRACTURED ROCK

    EPA Science Inventory

    Remediation of fractured rock sites contaminated by non-aqueous phase liquids has long been recognized as the most difficult undertaking of any site clean-up. Recent pilot studies conducted at the Edwards Air Force Base in California and the former Loring Air Force Base in Maine ...

  7. Use of a fluorescent chemical as a quality indicator for a hospital cleaning program.

    PubMed

    Blue, Jennifer; O'Neill, Cindy; Speziale, Paul; Revill, Jeff; Ramage, Lee; Ballantyne, Lisa

    2008-01-01

    Hamilton Health Sciences is a large teaching hospital with over 1,000 beds and consists of three acute care sites, one Regional Cancer Center and two Rehabilitation/Chronic Care facilities. An environmental cleaning pilot project was initiated at the acute care Henderson site, following an outbreak of vancomycin-resistant Enterococcus (VRE). Healthcare-associated infections (HAI) due to antibiotic-resistant organisms are increasing in Southern Ontario. Environmental cleaning plays a key role in eradicating resistant organisms that live in hospital environments, thereby helping to reduce HAIs. The environmental cleaning practices on the Orthopaedic Unit were identified as a contributing factor to the VRE outbreak after visual assessments were completed using a Brevis GlitterBug product, a chemical that fluoresces under an ultraviolet (UV) lamp. These findings led to a hospital-wide cleaning improvement initiative on all units except critical care areas. The GlitterBug potion was employed by Infection Control and Customer Support Services (CSS) as a tool to evaluate the daily cleaning of patient washrooms as well as discharge cleaning of contact precaution isolation rooms. Over a four-week period, the GlitterBug potion was applied to seven frequently touched standard targets in randomly selected patient bathrooms on each unit and 14 frequently touched targets prior to cleaning in the rooms used for isolation. The targets were then evaluated using the UV lamp to detect objects that were not cleaned and the results were recorded on a standardized form. The rate of targets cleaned versus the targets missed was calculated. The overall rate for daily cleaning of bathrooms and cleaning of isolation rooms was poor with only 23% of the targets cleaned. Based on these findings, several interventions were implemented. This resulted in a significant improvement in cleaning practices during the pilot project. Greater than 80% of the targets were cleaned compared to the baseline findings of 23%. Subsequently, nosocomial cases of VRE have declined despite the increased prevalence of VRE in the Hamilton and surrounding regions. The GlitterBug product is an effective tool to evaluate environmental cleaning and adherence to policies and procedures and this method was superior to previous visual inspection methods. The use of GlitterBug potion improved physical cleaning and enhanced staff contribution. The Brevis GlitterBug product was incorporated into the CSS environmental cleaning program at Hamilton Health Sciences as a quality indicator to monitor environmental cleaning practices.

  8. [Reduction of exposure to particulate matter in classrooms by improved cleaning: extent of exposure and results of a pilot study in Bavaria].

    PubMed

    Twardella, D; Fromme, H; Dietrich, S; Dietrich, W C

    2009-02-01

    The aims of the research project were (I) to describe the exposure to particulate matter in Bavarian schools and identify predictors of increased exposure and (II) to evaluate whether exposure can be reduced by improving the ventilation and/or cleaning routine. Air quality was measured in 46 schools, two classrooms each, in the City of Munich and Dachau county. Each classroom was measured on one school day in both winter 2004/2005 and summer 2005. The continuously generated data on particulate matter during the teaching hours were summarised to daily medians and the possible association of the median concentration with classroom characteristics was tested using non-parametric methods. In winter, the median PM (2.5) concentration was 18.8 microg/m (3), in summer 12.7 microg/m (3). The median PM (10) concentration was 91.5 microg/m (3) in winter and 64.9 microg/m (3) in summer. Determinants of a high particulate matter concentration were the winter period, an increased number of pupils or decreased room size, a high CO(2) concentration, and a low class level. Following this survey, a pilot study on the effects of improved cleaning and ventilation routines was conducted in autumn 2005. Three conditions were tested in two classrooms of one school: (a) standard, (b) improved airing (3 min during short and 20 min during long breaks), and (c) improved airing and improved cleaning (thorough cleaning once and vacuuming before wet wiping). Each condition was implemented for 2 weeks and particulate matter concentrations measured concurrently. In both rooms a reduction of both PM (2.5) and PM (10) concentration was found following improved airing and a further reduction occurred when improved cleaning was introduced in addition. However, in a linear regression accounting for other factors (room, physical activity of the pupils, outdoor concentration of particulate matter) the effect of improved airing was no longer significant, while the effect of improved cleaning remained at a reduction of 6 microg/m (3) for PM (2.5) and of 30 microg/m (3) for PM (10). The research projects show, that exposure to particulate matter in schools is high and indicate that, in particular, improved cleaning may be an effective measure to reduce the indoor particulate matter concentration. More and larger studies are needed to prove the efficacy of this measure.

  9. Emission measurement and safety assessment for the production process of silicon nanoparticles in a pilot-scale facility

    NASA Astrophysics Data System (ADS)

    Wang, Jing; Asbach, Christof; Fissan, Heinz; Hülser, Tim; Kaminski, Heinz; Kuhlbusch, Thomas A. J.; Pui, David Y. H.

    2012-03-01

    Emission into the workplace was measured for the production process of silicon nanoparticles in a pilot-scale facility at the Institute of Energy and Environmental Technology e.V. (IUTA). The silicon nanoparticles were produced in a hot-wall reactor and consisted of primary particles around 60 nm in diameter. We employed real-time aerosol instruments to measure particle number and lung-deposited surface area concentrations and size distribution; airborne particles were also collected for off-line electron microscopic analysis. Emission of silicon nanoparticles was not detected during the processes of synthesis, collection, and bagging. This was attributed to the completely closed production system and other safety measures against particle release which will be discussed briefly. Emission of silicon nanoparticles significantly above the detection limit was only observed during the cleaning process when the production system was open and manually cleaned. The majority of the detected particles was in the size range of 100-400 nm and were silicon nanoparticle agglomerates first deposited in the tubing then re-suspended during the cleaning process. Appropriate personal protection equipment is recommended for safety protection of the workers during cleaning.

  10. 40 CFR Appendix - Tables to Subpart B of Part 88

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 21 2012-07-01 2012-07-01 false Tables to Subpart B of Part 88 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) CLEAN-FUEL VEHICLES California Pilot Test Program State opt-in for the California Pilot Test Program. Pt. 88, Subpt. B, Tables Tables to Subpart B of Part 88...

  11. 40 CFR Appendix - Tables to Subpart B of Part 88

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 21 2013-07-01 2013-07-01 false Tables to Subpart B of Part 88 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) CLEAN-FUEL VEHICLES California Pilot Test Program State opt-in for the California Pilot Test Program. Pt. 88, Subpt. B, Tables Tables to Subpart B of Part 88...

  12. 40 CFR Appendix - Tables to Subpart B of Part 88

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 20 2010-07-01 2010-07-01 false Tables to Subpart B of Part 88 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) CLEAN-FUEL VEHICLES California Pilot Test Program State opt-in for the California Pilot Test Program. Pt. 88, Subpart B, Tables Tables to Subpart B of Part 88...

  13. 40 CFR Appendix - Tables to Subpart B of Part 88

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 20 2011-07-01 2011-07-01 false Tables to Subpart B of Part 88 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) CLEAN-FUEL VEHICLES California Pilot Test Program State opt-in for the California Pilot Test Program. Pt. 88, Subpart B, Tables Tables to Subpart B of Part 88...

  14. Effects of indoor air purification by an air cleaning system (Koala technology) on semen parameters in male factor infertility: results of a pilot study.

    PubMed

    Paradisi, R; Vanella, S; Barzanti, R; Cani, C; Battaglia, C; Seracchioli, R; Venturoli, S

    2009-06-01

    A number of studies indicated a clear decline in semen quality in the past 30-50 years and there is accumulating evidence that this decline might result from exposure to high levels of air pollution. To examine the impact of environment on male reproductive ability, we undertook for the first time a pilot study on semen quality of infertile men exposed to purification of indoor air. Ten subjects with a history of unexplained male infertility and poor semen quality were exposed for at least 1 year to a cleaning indoor air system (Koala technology). The key feature of this air purifier is the unique innovative multiple filtering system. The treatment of total purification of indoor air showed neither improvements in semen parameters nor variation in reproductive hormones (P = N.S.), but induced an evident increase (P < 0.03 and more) in seminal leucocytic concentrations. Within the limits due to the small sample of subjects recruited, the sole purification of indoor air does not seem enough to improve semen quality, although the increase in leucocytic concentrations could indicate an activation of the role of immunosurveillance in a purified indoor air environment.

  15. Inspections of Hand Washing Supplies and Hand Sanitizer in Public Schools

    ERIC Educational Resources Information Center

    Ramos, Mary M.; Blea, Mary; Trujillo, Rebecca; Greenberg, Cynthia

    2010-01-01

    Hand washing and hand antisepsis are proven infection control measures in the school setting, yet barriers such as lack of soap, paper towels, and hand sanitizer can hinder compliance. This pilot study measured the prevalence of hand cleaning supplies in public schools. Ten school districts (93 schools) participated in school nurse inspections. In…

  16. 40 CFR Appendix - Tables to Subpart B of Part 88

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 20 2014-07-01 2013-07-01 true Tables to Subpart B of Part 88 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) CLEAN-FUEL VEHICLES California Pilot Test Program State opt-in for the California Pilot Test Program. Pt. 88, Subpt. B, Tables Tables to Subpart B of Part 88 Tabl...

  17. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Buchholz, Stuart A.

    This memorandum documents laboratory thermomechanical triaxial strength testing of Waste Isolation Pilot Plant (WIPP) clean salt. The limited study completed independent, adjunct laboratory tests in the United States to assist in validating similar testing results being provided by the German facilities. The testing protocol consisted of completing confined triaxial, constant strain rate strength tests of intact WIPP clean salt at temperatures of 25°C and 100°C and at multiple confining pressures. The stratigraphy at WIPP also includes salt that has been labeled “argillaceous.” The much larger test matrix conducted in Germany included both the so-called clean and argillaceous salts. When combined,more » the total database of laboratory results will be used to develop input parameters for models, assess adequacy of existing models, and predict material behavior. These laboratory studies are also consistent with the goals of the international salt repository research program. The goal of this study was to complete a subset of a test matrix on clean salt from the WIPP undertaken by German research groups. The work was performed at RESPEC in Rapid City, South Dakota. A rigorous Quality Assurance protocol was applied, such that corroboration provides the potential of qualifying all of the test data gathered by German research groups.« less

  18. A lesson program for schoolchildren about a clean and healthy life-style: a pilot study.

    PubMed

    Hollander, C

    1997-05-01

    A health education project is underway in primary schools in the Wonogiri district of Indonesia. This project, implemented by the Yayasan Indonesia Sejahtera (YIS), is related to the Perilaku Hidup Bersih dan Sehat (PHBS) campaign developed by the Provincial Health Office of central Java to promote a healthy life-style. The PHBS campaign, which will eventually target households, industry, and schools, is currently promoting only 10 household-level indicators. Thus, YIS developed a curriculum for PHBS that includes those indicators that are relevant to primary school students. The longterm YIS project group includes the fifth-grade (11- and 12-year-old students) at every elementary school in the district. A single class in a village school is serving as the target group for the pilot study. Development of the pilot curriculum involved a pre/post test as well as a field test, and an evaluation is planned. The health topics chosen for the project are: clean water, use of family sanitation facilities, garbage disposal, mosquitoes, personal hygiene, dental hygiene, nutrition, smoking and alcohol, and family planning. The curriculum consists of seven lessons and is taught using visual aids and a participatory approach. Post-test results were disappointing because answers improved over pretest answers for only 5 out of 21 questions. One of the reasons may have been that the project had to begin before all of the supporting materials were ready. Evaluation is currently ongoing, and plans are underway to expand the program.

  19. 76 FR 31611 - Biennial Determination of the Waste Isolation Pilot Plant's Compliance with Applicable Federal...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-06-01

    ... documentation submitted by the U.S. Department of Energy (DOE) for the Waste Isolation Pilot Plant (WIPP), the U... requirements designated in Section 9(a)(1) of the WIPP Land Withdrawal Act, as amended. The Secretary of Energy...) the Clean Air Act; (3) the Solid Waste Disposal Act; (4) the Safe Drinking Water Act; (5) the Toxic...

  20. Homer City Multistream Coal Cleaning Demonstration: A progress report. Report for January 1979-July 1983

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Carey, D.W.; Higgins, S.T.; Slowik, A.A.

    1984-08-01

    The report gives an overview of ongoing testing and evaluation of the Homer City Coal Cleaning Plant, built to enable the Homer City Power Complex to meet sulfur dioxide (SO2) emission levels mandated by the State of Pennsylvania and the U.S. Government. The plant was constructed as a result of an extensive comparative evaluation of flue gas desulfurization (FGD) and physical coal cleaning. The Homer City System, the Multistream Coal Cleaning System (MCCS), was chosen as an economical alternative to FGD. The plant contains circuits for cleaning coarse, medium, and fine coals and for recovering fine and very fine coals.more » The dominant type of cleaning equipment used in the plant is the dense medium cyclone. The original '93 plant' configuration was never able to clean coal to the conditions specified in the plant design. An extensive test and evaluation program was begun to identify and correct the causes of plant operating problems. After extensive pilot plant equipment tests and engineering studies were completed, recommendations were made for plant modifications necessary to correct the design and operating deficiencies of the plant. Extensive modifications were made to one of two parallel processing trains in the plant (the 'B' circuits), and a test program was initiated to evaluate these corrective measures. The modified 'B' circuits have not yet met design conditions.« less

  1. Implementation of remote video auditing with feedback and compliance for manual-cleaning protocols of endoscopic retrograde cholangiopancreatography endoscopes.

    PubMed

    Armellino, Donna; Cifu, Kelly; Wallace, Maureen; Johnson, Sherly; DiCapua, John; Dowling, Oonagh; Jacobs, Mitchel; Browning, Susan

    2018-05-01

    A pilot initiative to assess the use of remote video auditing in monitoring compliance with manual-cleaning protocols for endoscopic retrograde cholangiopancreatography (ERCP) endoscopes was performed. Compliance with manual-cleaning steps following the initiation of feedback was measured. A video feed of the ERCP reprocessing room was provided to remote auditors who scored items of an ERCP endoscope manual-cleaning checklist. Compliance feedback was provided in the form of reports and reeducation. Outcomes were reported as checklist compliance. The use of remote video auditing to document manual processing is a feasible approach and feedback and reeducation increased manual-cleaning compliance from 53.1% (95% confidence interval, 34.7-71.6) to 98.9% (95.0% confidence interval, 98.1-99.6). Copyright © 2018 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  2. Mobile zoned/exponential LAF screen: a new concept in ultra-clean air technology for additional operating room ventilation.

    PubMed

    Friberg, B; Lindgren, M; Karlsson, C; Bergström, A; Friberg, S

    2002-04-01

    A mobile screen (0.5 x 0.4 m) producing ultra-clean exponential LAF (air-flow central zone 0.6 m/s and peripheral zone 0.4 m/s) was investigated as an addition to conventional turbulent/mixing operating room ventilation. The evaluation was performed during strictly standardized sham operations reflecting conditions during major surgery. The study consisted of a pilot experiment designed to give high counts of sedimenting aerobic colony forming units (cfu). In a second main study, recording dust particles, air-borne and sedimenting aerobic cfu, the screen was associated with optimal operating room clothing. In the pilot experiment the use of the screen resulted in a substantial reduction of sedimenting bacteria from 3835-4940 to 0-390 cfu/m(2)/h. In the main study, the use of the additional LAF reduced the surface contamination from 416-329 to 7-78 cfu/m(2)/h up to 1.6 m from the screen (P=0.001-0.0001). Measured in the wound area the screen reduced the air counts of bacteria from 9-14 to 0.2-0.4 cfu/m(3) (P=0.008-0.0001) and a marked reduction of air-borne dust particles was recorded (P=0.007-0.009). In conclusion, the additional mobile LAF screen reduced the counts of aerobic air-borne and sedimenting bacteria-carrying particles as well as dust particles to the levels gained with complete ultra-clean LAF room ventilation. Thus, the screen might prove a valuable addition to operating room ventilation as well as in other areas where asepsis is essential. Copyright 2002 The Hospital Infection Society.

  3. Development of a clean optical telescope

    NASA Technical Reports Server (NTRS)

    Brown, R. A.

    1983-01-01

    Particulate contamination on astronomical mirrors degrades performance in two ways: by information loss by extinction of light; and background and noise from scattering, especially forward or Fraunhofer scattering. These effects were not generally understood, and an ambitious pilot program was outlined to measure particulate effects on telescope optical performance; develop prophylactic and cleaning procedures suitable for groundbased observatories; investigate by computational modelling the effects on telescopes in space; and communicate the results and concerns within the astronomical community.

  4. Characterization of occupational exposures to cleaning products used for common cleaning tasks--a pilot study of hospital cleaners.

    PubMed

    Bello, Anila; Quinn, Margaret M; Perry, Melissa J; Milton, Donald K

    2009-03-27

    In recent years, cleaning has been identified as an occupational risk because of an increased incidence of reported respiratory effects, such as asthma and asthma-like symptoms among cleaning workers. Due to the lack of systematic occupational hygiene analyses and workplace exposure data, it is not clear which cleaning-related exposures induce or aggravate asthma and other respiratory effects. Currently, there is a need for systematic evaluation of cleaning products ingredients and their exposures in the workplace. The objectives of this work were to: a) identify cleaning products' ingredients of concern with respect to respiratory and skin irritation and sensitization; and b) assess the potential for inhalation and dermal exposures to these ingredients during common cleaning tasks. We prioritized ingredients of concern in cleaning products commonly used in several hospitals in Massachusetts. Methods included workplace interviews, reviews of product Materials Safety Data Sheets and the scientific literature on adverse health effects to humans, reviews of physico-chemical properties of cleaning ingredients, and occupational hygiene observational analyses. Furthermore, the potential for exposure in the workplace was assessed by conducting qualitative assessment of airborne exposures and semi-quantitative assessment of dermal exposures. Cleaning products used for common cleaning tasks were mixtures of many chemicals, including respiratory and dermal irritants and sensitizers. Examples of ingredients of concern include quaternary ammonium compounds, 2-butoxyethanol, and ethanolamines. Cleaning workers are at risk of acute and chronic inhalation exposures to volatile organic compounds (VOC) vapors and aerosols generated from product spraying, and dermal exposures mostly through hands. Cleaning products are mixtures of many chemical ingredients that may impact workers' health through air and dermal exposures. Because cleaning exposures are a function of product formulations and product application procedures, a combination of product evaluation with workplace exposure assessment is critical in developing strategies for protecting workers from cleaning hazards. Our task based assessment methods allowed classification of tasks in different exposure categories, a strategy that can be employed by epidemiological investigations related to cleaning. The methods presented here can be used by occupational and environmental health practitioners to identify intervention strategies.

  5. Characterization of occupational exposures to cleaning products used for common cleaning tasks-a pilot study of hospital cleaners

    PubMed Central

    2009-01-01

    Background In recent years, cleaning has been identified as an occupational risk because of an increased incidence of reported respiratory effects, such as asthma and asthma-like symptoms among cleaning workers. Due to the lack of systematic occupational hygiene analyses and workplace exposure data, it is not clear which cleaning-related exposures induce or aggravate asthma and other respiratory effects. Currently, there is a need for systematic evaluation of cleaning products ingredients and their exposures in the workplace. The objectives of this work were to: a) identify cleaning products' ingredients of concern with respect to respiratory and skin irritation and sensitization; and b) assess the potential for inhalation and dermal exposures to these ingredients during common cleaning tasks. Methods We prioritized ingredients of concern in cleaning products commonly used in several hospitals in Massachusetts. Methods included workplace interviews, reviews of product Materials Safety Data Sheets and the scientific literature on adverse health effects to humans, reviews of physico-chemical properties of cleaning ingredients, and occupational hygiene observational analyses. Furthermore, the potential for exposure in the workplace was assessed by conducting qualitative assessment of airborne exposures and semi-quantitative assessment of dermal exposures. Results Cleaning products used for common cleaning tasks were mixtures of many chemicals, including respiratory and dermal irritants and sensitizers. Examples of ingredients of concern include quaternary ammonium compounds, 2-butoxyethanol, and ethanolamines. Cleaning workers are at risk of acute and chronic inhalation exposures to volatile organic compounds (VOC) vapors and aerosols generated from product spraying, and dermal exposures mostly through hands. Conclusion Cleaning products are mixtures of many chemical ingredients that may impact workers' health through air and dermal exposures. Because cleaning exposures are a function of product formulations and product application procedures, a combination of product evaluation with workplace exposure assessment is critical in developing strategies for protecting workers from cleaning hazards. Our task based assessment methods allowed classification of tasks in different exposure categories, a strategy that can be employed by epidemiological investigations related to cleaning. The methods presented here can be used by occupational and environmental health practitioners to identify intervention strategies. PMID:19327131

  6. Can education influence stethoscope hygiene?

    PubMed

    Holleck, Jürgen L; Merchant, Naseema; Lin, Shin; Gupta, Shaili

    2017-07-01

    The importance of stethoscope hygiene has been demonstrated in prior studies, and is acknowledged by guidelines, yet it is rarely done. We implemented a pilot project consisting of provider education, reminder flyers and provision of cleaning supplies at the start of clinical rotations for housestaff, medical students, and attending physicians. Hand hygiene rates did not change significantly with rates between 58% and 63% while stethoscope hygiene remained at zero. Published by Elsevier Inc.

  7. Peer tutoring pilot program for the improvement of oral health behavior in underprivileged and immigrant children.

    PubMed

    Reinhardt, Claus H; Löpker, Nadine; Noack, Michael J; Klein, Klaus; Rosen, Evelyne

    2009-01-01

    Caries prevalence in underprivileged children is particularly high and, even though many efforts have been made, adherence to dental preventive programs is low. The purpose of this study was to evaluate whether a tutoring program can improve oral health behavior in underprivileged and/or immigrant children. Thirty fourth-grade children (mean age = 9.6), over 50 percent of immigrant background, participated in this longitudinal pilot study. The fourth graders were invited to develop on oral health program for their first-grade peers. For this purpose, the fourth graders learned oral health practices and developed the peer tutoring program. Prior to the intervention and after having instructed their first-grade peers, all fourth graders were interviewed about their oral health habits and their tooth-brushing was recorded on video. Toothbrushing time, performance of circular tooth-brushing movements, and systematic cleaning of all dental surfaces were analyzed before and after the intervention. After peer teaching, there was a significant increase concerning tooth-brushing time (P = .004), performance of circular tooth-brushing movements (P < .001), and systematic cleaning of all dental surfaces (P < .001). The tutoring program yielded a significant improvement in relevant oral care behavior. This approach provided an environment which, in contrast to traditional approaches, facilitates empowerment.

  8. STS-30 clean-suited crewmembers examine locker contents during bench review

    NASA Technical Reports Server (NTRS)

    1989-01-01

    During a bench review, STS-30 crewmembers, wearing clean suits, examine configuration of middeck lockers packed with stowage bags and hygiene supplies. The bay will be used to contain objects not in use while in orbit. From left to right are Mission Specialist (MS) Mark C. Lee, MS Norman E. Thagard, Commander David M. Walker, MS Mary L. Cleave, and Pilot Ronald J. Grabe. Technicians and personnel filming bench review look on. Photo taken by JSC photographer Jack Jacob.

  9. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Curtin, D.P.

    The process analyzed involves non-production, laboratory environment use of trichloroethylene for the cleaning of semiconductor devices. The option selection centered on the replacement of the trichloroethylene with a non-hazardous material. This process waste assessment was performed as part of a pilot project.

  10. A pilot-scale study of wet torrefaction treatment for upgrading palm oil empty fruit bunches as clean solid fuel

    NASA Astrophysics Data System (ADS)

    Gusman, M. H.; Sastroredjo, P. N. E.; Prawisudha, P.; Hardianto, T.; Pasek, A. D.

    2017-05-01

    Less utilized empty fruit bunch (EFB) is seldom used as solid biofuel due to its high alkali content that potentially cause ash deposit called slagging and fouling. This phenomenon could harm biomass-fired power plant equipment. Some pre-treatment of EFB is needed to reduce EFB ash deposit potential. The effect of wet torrefaction pre-treatment in laboratory scale was successfully proven in decreasing slagging and fouling potential while increasing EFB calorific value that could fulfill clean solid fuel criteria. This research focuses on wet torrefaction process that conducted on a pilot scale with the capacity of 250 liters. It was found that wet torrefaction process can improve the product’s calorific value up to 9.41% while reduce its ash content down to 1.01% comparing to the raw EFB. The reduction of ash content also leads to the reduction of slagging and fouling tendency that presents in terms of alkali index. Alkali index is a quantitative method that can be calculated after obtaining metal oxides fraction on solid fuel. Metal oxides could be obtained by using energy dispersive x-ray spectroscopy.

  11. Gas-Liquid Supersonic Cleaning and Cleaning Verification Spray System

    NASA Technical Reports Server (NTRS)

    Parrish, Lewis M.

    2009-01-01

    NASA Kennedy Space Center (KSC) recently entered into a nonexclusive license agreement with Applied Cryogenic Solutions (ACS), Inc. (Galveston, TX) to commercialize its Gas-Liquid Supersonic Cleaning and Cleaning Verification Spray System technology. This technology, developed by KSC, is a critical component of processes being developed and commercialized by ACS to replace current mechanical and chemical cleaning and descaling methods used by numerous industries. Pilot trials on heat exchanger tubing components have shown that the ACS technology provides for: Superior cleaning in a much shorter period of time. Lower energy and labor requirements for cleaning and de-scaling uper.ninih. Significant reductions in waste volumes by not using water, acidic or basic solutions, organic solvents, or nonvolatile solid abrasives as components in the cleaning process. Improved energy efficiency in post-cleaning heat exchanger operations. The ACS process consists of a spray head containing supersonic converging/diverging nozzles, a source of liquid gas; a novel, proprietary pumping system that permits pumping liquid nitrogen, liquid air, or supercritical carbon dioxide to pressures in the range of 20,000 to 60,000 psi; and various hoses, fittings, valves, and gauges. The size and number of nozzles can be varied so the system can be built in configurations ranging from small hand-held spray heads to large multinozzle cleaners. The system also can be used to verify if a part has been adequately cleaned.

  12. Biosorption for the separation of radionuclides from drainage and process waters of the uranium mining industry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Glombitza, F.; Eckardt, L.; Hummel, A.

    1995-12-31

    Biosorption means the storage of substances at the cell envelope. Different microbial biomasses were tested for the separation of radionuclides from mining waters. Results of a pilot plant demonstrate the ability of these techniques for water cleaning processes. An effluent concentration of lower than 1 mg/l (in most cases 0.1 mg/1) could be realized in a pilot plant by using pure cells of a methylotrophic strain of bacteria as well as using of a fungal mycelia.

  13. Unraveling heavy oil desulfurization chemistry: targeting clean fuels.

    PubMed

    Choudhary, Tushar V; Parrott, Stephen; Johnson, Byron

    2008-03-15

    The sulfur removal chemistry of heavy oils has been unraveled by systematically investigating several heavy oils with an extremely wide range of properties. The heavy oil feed and product properties have been characterized by advanced analytical methods, and these properties have been related to the sulfur conversion data observed in pilot hydrotreating units. These studies coupled with kinetic treatment of the data have revealed that the desulfurization chemistry of heavy oils is essentially controlled by the strongly inhibiting three and larger ring aromatic hydrocarbon content and surprisingly not by the content of the "hard-to-remove" sulfur compounds. Such enhanced understanding of the heavy oil sulfur removal is expected to open new avenues for catalyst/process optimization for heavy oil desulfurization and thereby assist the efficent production of clean transporation fuels.

  14. Development of a bar code-based exposure assessment method to evaluate occupational exposure to disinfectants and cleaning products: a pilot study.

    PubMed

    Quinot, Catherine; Amsellem-Dubourget, Sylvie; Temam, Sofia; Sevin, Etienne; Barreto, Christine; Tackin, Arzu; Félicité, Jérémy; Lyon-Caen, Sarah; Siroux, Valérie; Girard, Raphaële; Descatha, Alexis; Le Moual, Nicole; Dumas, Orianne

    2018-05-14

    Healthcare workers are highly exposed to various types of disinfectants and cleaning products. Assessment of exposure to these products remains a challenge. We aimed to investigate the feasibility of a method, based on a smartphone application and bar codes, to improve occupational exposure assessment among hospital/cleaning workers in epidemiological studies. A database of disinfectants and cleaning products used in French hospitals, including their names, bar codes and composition, was developed using several sources: ProdHyBase (a database of disinfectants managed by hospital hygiene experts), and specific regulatory agencies and industrial websites. A smartphone application has been created to scan bar codes of products and fill a short questionnaire. The application was tested in a French hospital. The ease of use and the ability to record information through this new approach were estimated. The method was tested in a French hospital (7 units, 14 participants). Through the application, 126 records (one record referred to one product entered by one participant/unit) were registered, majority of which were liquids (55.5%) or sprays (23.8%); 20.6% were used to clean surfaces and 15.9% to clean toilets. Workers used mostly products with alcohol and quaternary ammonium compounds (>90% with weekly use), followed by hypochlorite bleach and hydrogen peroxide (28.6%). For most records, information was available on the name (93.7%) and bar code (77.0%). Information on product compounds was available for all products and recorded in the database. This innovative and easy-to-use method could help to improve the assessment of occupational exposure to disinfectants/cleaning products in epidemiological studies. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  15. Sensory Adapted Dental Environments to Enhance Oral Care for Children with Autism Spectrum Disorders: A Randomized Controlled Pilot Study

    PubMed Central

    Cermak, Sharon A.; Stein Duker, Leah I.; Williams, Marian E.; Dawson, Michael E.; Lane, Christianne J.; Polido, José C.

    2015-01-01

    This pilot and feasibility study examined the impact of a sensory adapted dental environment (SADE) to reduce distress, sensory discomfort, and perception of pain during oral prophylaxis for children with autism spectrum disorder (ASD). Participants were 44 children ages 6-12 (n=22 typical, n=22 ASD). In an experimental crossover design, each participant underwent two professional dental cleanings, one in a regular dental environment (RDE) and one in a SADE, administered in a randomized and counterbalanced order three to four months apart. Outcomes included measures of physiological anxiety, behavioral distress, pain intensity, and sensory discomfort. Both groups exhibited decreased physiological anxiety and reported lower pain and sensory discomfort in the SADE condition compared to RDE, indicating a beneficial effect of the SADE. PMID:25931290

  16. Magnetic susceptibility of spider webs as a proxy of airborne metal pollution.

    PubMed

    Rachwał, Marzena; Rybak, Justyna; Rogula-Kozłowska, Wioletta

    2018-03-01

    The purpose of this pilot study was to test spider webs as a fast tool for magnetic biomonitoring of air pollution. The study involved the investigation of webs made by four types of spiders: Pholcus phalangioides (Pholcidae), Eratigena atrica and Agelena labirynthica (Agelenidae) and Linyphia triangularis (Linyphiidae). These webs were obtained from outdoor and indoor study sites. Compared to the clean reference webs, an increase was observed in the values of magnetic susceptibility in the webs sampled from both indoor and outdoor sites, which indicates contamination by anthropogenically produced pollution particles that contain ferrimagnetic iron minerals. This pilot study has demonstrated that spider webs are able to capture particulate matter in a manner that is equivalent to flora-based bioindicators applied to date (such as mosses, lichens, leaves). They also have additional advantages; for example, they can be generated in isolated clean habitats, and exposure can be monitored in indoor and outdoor locations, at any height and for any period of time. Moreover, webs are ubiquitous in an anthropogenic, heavily polluted environment, and they can be exposed throughout the year. As spider webs accumulate pollutants to which humans are exposed, they become a reliable source of information about the quality of the environment. Therefore, spider webs are recommended for magnetic biomonitoring of airborne pollution and for the assessment of the environment because they are non-destructive, low-cost, sensitive and efficient. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. Sadie Cox | NREL

    Science.gov Websites

    , advancing technical solutions for resilient power systems, and assessing development impacts of clean energy applications in developing countries Distributed generation policies and impacts Education M.A. in global Impacts Associated with Low Emission Development Strategies: Lessons Learned from Pilot Efforts in Kenya

  18. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Erga, O.; Finborud, A.

    Cost-effective FGD processes with high SO{sub 2} removal efficiencies are required for fossil-fired power plants. With high-sulfur fuel, conventional limestone processes are less ideal, and regenerative processes with SO{sub 2} recovery may offer important advantages. The Elsorb process, which is being developed by the Norwegian company Elkem Technology a.s., is a regenerable SO{sub 2} recovery process which operates on the principle of chemical absorption followed by regeneration by evaporation. The process is based on the use of a chemical stable sodium phosphate buffer in high concentration. It combines high cleaning efficiency with high cyclic absorption capacity, moderate energy requirement, andmore » very little oxidation losses. The process produces SO{sub 2} (g) which can be converted into liquid SO{sub 2}, sulfuric acid or elemental sulfur. The Elsorb process has been pilot tested on flue gas from a coal-fired boiler with very promising results, concerning cleaning efficiency and oxidation losses of SO{sub 2}. The first commercial Elsorb plant has been installed for treating incinerated Claus tail gas. Preliminary data regarding cleaning efficiency are in accordance with the pilot tests. However, unexpected high consumption of make-up chemicals were encountered. The existing incinerator is now to be modified. Complete data for the Elsorb plant should be available later this year. 1 fig.« less

  19. Delayed flap approach procedures for noise abatement and fuel conservation

    NASA Technical Reports Server (NTRS)

    Edwards, F. G.; Bull, J. S.; Foster, J. D.; Hegarty, D. M.; Drinkwater, F. J., III

    1976-01-01

    The NASA/Ames Research Center is currently investigating the delayed flap approach during which pilot actions are determined and prescribed by an onboard digital computer. The onboard digital computer determines the proper timing for the deployment of the landing gear and flaps based on the existing winds and airplane gross weight. Advisory commands are displayed to the pilot. The approach is flown along the conventional ILS glide slope but is initiated at a higher airspeed and in a clean aircraft configuration that allows for low thrust and results in reduced noise and fuel consumption. Topics discussed include operational procedures, pilot acceptability of these procedures, and fuel/noise benefits resulting from flight tests and simulation.

  20. Evaluation of a pilot-scale sewage biogas powered 2.8 kWe Solid Oxide Fuel Cell: Assessment of heat-to-power ratio and influence of oxygen content

    NASA Astrophysics Data System (ADS)

    de Arespacochaga, N.; Valderrama, C.; Peregrina, C.; Mesa, C.; Bouchy, L.; Cortina, J. L.

    2015-12-01

    Biogas from anaerobic digestion of organic matter is a promising renewable energy source and fuel cells appear as a breakthrough technology to improve the performance of the biogas-to-energy valorisation chain. The vast majority of studies addressing biogas energy recovery through Solid Oxide Fuel Cells published in recent years correspond to simulations and lab-scale performance with synthetic biogas. This paper assesses the pilot performance of a 2.8 kWe SOFC unit powered with cleaned sewage biogas for around 700 h in a Wastewater Treatment Plant. The biogas thorough treatment consisting of a biological desulphurisation with a biotrickling filter followed by a deep cleaning step based on adsorption is successful for removing sulphur compounds, siloxanes and hydrocarbons. The influence of the heat-to-power ratio on fuel cell performance is investigated operating the system at O/C ratio of 2, reforming temperature of 550 °C, stack temperature of 800 °C and at a constant voltage of 43 V. At optimized conditions for electrical production satisfying heat demand in the WWTP, system electrical and thermal efficiencies account for 34% and 28%. Cogeneration efficiency remains constant at around 59-62% for all the heat-to-power ratios tested. Furthermore, the impact of the oxygen content in the biogas is also studied.

  1. Sustainable in-well vapor stripping: A design, analytical model, and pilot study for groundwater remediation

    NASA Astrophysics Data System (ADS)

    Sutton, Patrick T.; Ginn, Timothy R.

    2014-12-01

    A sustainable in-well vapor stripping system is designed as a cost-effective alternative for remediation of shallow chlorinated solvent groundwater plumes. A solar-powered air compressor is used to inject air bubbles into a monitoring well to strip volatile organic compounds from a liquid to vapor phase while simultaneously inducing groundwater circulation around the well screen. An analytical model of the remediation process is developed to estimate contaminant mass flow and removal rates. The model was calibrated based on a one-day pilot study conducted in an existing monitoring well at a former dry cleaning site. According to the model, induced groundwater circulation at the study site increased the contaminant mass flow rate into the well by approximately two orders of magnitude relative to ambient conditions. Modeled estimates for 5 h of pulsed air injection per day at the pilot study site indicated that the average effluent concentrations of dissolved tetrachloroethylene and trichloroethylene can be reduced by over 90% relative to the ambient concentrations. The results indicate that the system could be used cost-effectively as either a single- or multi-well point technology to substantially reduce the mass of dissolved chlorinated solvents in groundwater.

  2. Airborne exposures to monoethanolamine, glycol ethers, and benzyl alcohol during professional cleaning: a pilot study.

    PubMed

    Melchior Gerster, Fabian; Brenna Hopf, Nancy; Pierre Wild, Pascal; Vernez, David

    2014-08-01

    A growing body of epidemiologic evidence suggests an association between exposure to cleaning products and respiratory dysfunction. Due to the lack of quantitative assessments of respiratory exposures to airborne irritants and sensitizers among professional cleaners, the culpable substances have yet to be identified. Focusing on previously identified irritants, our aims were to determine (i) airborne concentrations of monoethanolamine (MEA), glycol ethers, and benzyl alcohol (BA) during different cleaning tasks performed by professional cleaning workers and assess their determinants; and (ii) air concentrations of formaldehyde, a known indoor air contaminant. Personal air samples were collected in 12 cleaning companies, and analyzed by conventional methods. Nearly all air concentrations [MEA (n = 68), glycol ethers (n = 79), BA (n = 15), and formaldehyde (n = 45)] were far below (<1/10) of the corresponding Swiss occupational exposure limits (OEL), except for ethylene glycol mono-n-butyl ether (EGBE). For butoxypropanol and BA, no OELs exist. Although only detected once, EGBE air concentrations (n = 4) were high (49.48-58.72mg m(-3)), and close to the Swiss OEL (49mg m(-3)). When substances were not noted as present in safety data sheets of cleaning products used but were measured, air concentrations showed no presence of MEA, while the glycol ethers were often present, and formaldehyde was universally detected. Exposure to MEA was affected by its amount used (P = 0.036), and spraying (P = 0.000) and exposure to butoxypropanol was affected by spraying (P = 0.007) and cross-ventilation (P = 0.000). Professional cleaners were found to be exposed to multiple airborne irritants at low concentrations, thus these substances should be considered in investigations of respiratory dysfunctions in the cleaning industry; especially in specialized cleaning tasks such as intensive floor cleaning. © The Author 2014. Published by Oxford University Press on behalf of the British Occupational Hygiene Society.

  3. Quantitative assessment of the efficacy of spiral-wound membrane cleaning procedures to remove biofilms.

    PubMed

    Hijnen, W A M; Castillo, C; Brouwer-Hanzens, A H; Harmsen, D J H; Cornelissen, E R; van der Kooij, D

    2012-12-01

    Cleaning of high pressure RO/NF membranes is an important operational tool to control biofouling. Quantitative information on the efficacy of cleaning agents and protocols to remove biomass is scarce. Therefore, a laboratory cleaning test to assess the efficiency of cleaning procedures to remove attached biomass was developed. The major components of the test are (i) production of uniform biofilm samples, (ii) the quantification of the biomass concentrations with robust parameters and (iii) a simple test procedure with optimal exposure of the biofilm samples to the chemicals. The results showed that PVC-P is a suitable substratum for the production of uniform biofilm samples. ATP and carbohydrates (CH) as major components of the biofilm matrix for nucleotides (living bacterial cells) and extracellular polymeric substances EPS, respectively, were selected as robust biomass parameters. The removal of ATP and CH with the NaOH/Sodium Dodecyl Sulfate (SDS) mixture, selected as a standard treatment at pH 12.0, was reproducible. The resistance of the EPS matrix against chemical cleaning was demonstrated by a low CH removal (32.8 ± 6.0%) compared to the ATP removal (70.5 ± 15.1%). The inverse relationship of biomass removal with the CH to ATP ratio (μg/ng) of the biofilms demonstrated the influence of the biomass characteristics on cleaning. None of the 27 chemicals tested (analytical-grade and commercial brands) in single step or in double-step treatments were significantly more effective than NaOH/SDS. Oxidizing agents NaOCl and H(2)O(2), the latter in combination with SDS, both tested as common agents in biofilm control, showed a significantly higher efficiency (70%) to remove biofilms. In the test, simultaneously, the efficiency of agents to remove precipitated minerals such as Fe can be assessed. Validation tests with Cleaning in Place (CIP) in 8 and 2.5-inch RO membrane pilot plant experiments showed similar ranking of the cleaning efficiency of cleaning protocols as determined in the laboratory tests. Further studies with the laboratory test are required to study the effect of cleaning conditions such as duration, temperature, shear forces as well as chemical conditions (concentrations, alternative agents or mixtures and sequence of application) on the efficiency to remove attached biomass. Copyright © 2012 Elsevier Ltd. All rights reserved.

  4. EPA’s National Coastal Condition Assessment: Pilot research in Great Lakes connecting channels

    EPA Science Inventory

    The EPA Office of Water’s 5-year cycles of national surveys of wetlands, lakes, rivers, and coastal areas help satisfy the assessment and antidegradation provisions of the Clean Water Act. Measuring extant conditions precedes measuring change in conditions. Surveys are chal...

  5. Process waste assessment: Petroleum jelly removal from semiconductor die using trichloroethylene

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Curtin, D.P.

    The process analyzed involves non-production, laboratory environment use of trichloroethylene for the cleaning of semiconductor devices. The option selection centered on the replacement of the trichloroethylene with a non-hazardous material. This process waste assessment was performed as part of a pilot project.

  6. Energy Transitions | Integrated Energy Solutions | NREL

    Science.gov Websites

    clean energy access to remote populations across West Africa. NREL Supports Effort to Take Distributed develops and implements pilot projects to accelerate the development of distributed photovoltaics Renewable Energy into India's Electric Grid Volume 1 Volume 2 Designing Distributed Generation in Mexico

  7. Tannic acid for smear layer removal: pilot study with scanning electron microscope.

    PubMed

    Bitter, N C

    1989-04-01

    The effects of a 25% tannic acid solution applied to the surface of prepared dentin was compared with untreated prepared dentin surfaces. The following results were demonstrated by electron microscope observation: (1) cavity preparations created an amorphous dentinal smear layer, (2) placement of a 25% tannic acid solution for 15 seconds removed the smear layer, (3) the contents of the dentinal tubules were not removed and no enlargement of dentinal tubules was found, and (3) a clean dentinal surface was observed.

  8. Effective and Efficient Roadside Ditch Cleaning Using BMP's for Erosion and Sediment Control

    DOT National Transportation Integrated Search

    2017-09-01

    The Wyoming Department of Transportation (WYDOT) leads this pilot. WYDOT will develop systems that support the use of connected vehicle technology and applications along the 402 miles of I-80 in Wyoming. V2V and V2I applications will enable communica...

  9. In-Situ Air Sparaing: Engineering and Design

    DTIC Science & Technology

    2008-01-31

    Construction Materials. Although PVC casing is commonly used, flexible or rigid polyethylene pipe may be more efficient for certain excavation methods, such as...depth, etc.) Piping insulation/ heat tape installed Piping flushed/cleaned/pressure tested Subsurface as-built equipment...4-4 Figure 4-2 Pilot-Scale Piping and Instrumentation Diagram

  10. DEMONSTRATION BULLETIN: MOBILE VOLUME REDUCTION UNIT - U.S. ENVIRONMENTAL PROTECTION AGENCY

    EPA Science Inventory

    The Volume Reduction Unit (VRU), which was developed by EPA, is a mobile, pilot-scale soil washing system for stand-alone field use in cleaning soil contaminated with hazardous substances. Removal efficiencies depend on the contaminant as well as the type of soil. Soil washing...

  11. Sustainable in-well vapor stripping: A design, analytical model, and pilot study for groundwater remediation.

    PubMed

    Sutton, Patrick T; Ginn, Timothy R

    2014-12-15

    A sustainable in-well vapor stripping system is designed as a cost-effective alternative for remediation of shallow chlorinated solvent groundwater plumes. A solar-powered air compressor is used to inject air bubbles into a monitoring well to strip volatile organic compounds from a liquid to vapor phase while simultaneously inducing groundwater circulation around the well screen. An analytical model of the remediation process is developed to estimate contaminant mass flow and removal rates. The model was calibrated based on a one-day pilot study conducted in an existing monitoring well at a former dry cleaning site. According to the model, induced groundwater circulation at the study site increased the contaminant mass flow rate into the well by approximately two orders of magnitude relative to ambient conditions. Modeled estimates for 5h of pulsed air injection per day at the pilot study site indicated that the average effluent concentrations of dissolved tetrachloroethylene and trichloroethylene can be reduced by over 90% relative to the ambient concentrations. The results indicate that the system could be used cost-effectively as either a single- or multi-well point technology to substantially reduce the mass of dissolved chlorinated solvents in groundwater. Copyright © 2014 Elsevier B.V. All rights reserved.

  12. Significance of losses in water distribution systems in India

    PubMed Central

    Raman, V.

    1983-01-01

    Effective management of water supply systems consists in supplying adequate quantities of clean water to the population. Detailed pilot studies of water distribution systems were carried out in 9 cities in India during 1971-81 to establish the feasibility of a programme of assessment, detection, and control of water losses from supply systems. A cost-benefit analysis was carried out. Water losses from mains and service pipes in the areas studied amounted to 20-35% of the total flow in the system. At a conservative estimate, the national loss of processed water through leaks in the water distribution systems amounts to 1012 litres per year, which is equivalent to 500 million rupees. It is possible to bring down the water losses in the pipe mains to 3-5% of the total flow, and the cost incurred on the control programme can be recovered in 6-18 months. Appropriate conservation measures will help in achieving the goals of the International Water Supply and Sanitation Decade to provide clean water for all. PMID:6418401

  13. Significance of losses in water distribution systems in India.

    PubMed

    Raman, V

    1983-01-01

    Effective management of water supply systems consists in supplying adequate quantities of clean water to the population. Detailed pilot studies of water distribution systems were carried out in 9 cities in India during 1971-81 to establish the feasibility of a programme of assessment, detection, and control of water losses from supply systems. A cost-benefit analysis was carried out. Water losses from mains and service pipes in the areas studied amounted to 20-35% of the total flow in the system. At a conservative estimate, the national loss of processed water through leaks in the water distribution systems amounts to 10(12) litres per year, which is equivalent to 500 million rupees.It is possible to bring down the water losses in the pipe mains to 3-5% of the total flow, and the cost incurred on the control programme can be recovered in 6-18 months. Appropriate conservation measures will help in achieving the goals of the International Water Supply and Sanitation Decade to provide clean water for all.

  14. A Tale of Two Teaching Experiences

    ERIC Educational Resources Information Center

    Allen, Kerri

    2006-01-01

    In 1989, an ambitious Princeton University senior had an idea. Inspired to bridge the educational gap in the United States, Wendy Kopp formed a pilot program where enthusiastic grads like her would flood inner city schools and clean up the proverbial neighborhood. She even gave it an imperative and patriotic moniker: Teach for America. Seventeen…

  15. Innovation and Entrepreneurship | NREL

    Science.gov Websites

    disadvantaged businesses. Programs A photo of a woman and a man creating a planning diagram. Energy I-Corps (DOE) national laboratory-developed technologies into the commercial marketplace. Read more A photo of two men working on a machine. Small Business Vouchers Pilot Provides selected clean energy small

  16. IN SITU OXIDATION FIELD PILOT OF 1,4-DIOXANE AT THE COOPER DRUM SUPERFUND SITE

    EPA Science Inventory

    1,4-Dioxane, a solvent in paints, varnishes, lacquers, cosmetics, deodorants, cleaning and detergent preparations fluids, has attracted a lot of notice recently because its chemical analytical detection limit has recently been lowered from 50 µg/L to 1 µg/L. It is now commonly de...

  17. Tests on a pilot plant for reheating desulfurized flue gases with the help of heat pipes

    NASA Astrophysics Data System (ADS)

    Schug, W.

    1982-02-01

    Desulfurized flue gases were reheated with a heat pipe heat exchanger. Finned heat pipes, with a coating or made of high quality steel were subjected to different operating conditions for 1000 hr. The coating proved to be unsuitable for heat transfer because it swells and detaches itself from the background material. The high quality steels showed pitting and surface corrosion. The possibilities of cleaning were also studied to prevent deposits forming on the heat pipes, but no solution was found.

  18. Ceramic membrane defouling (cleaning) by air Nano Bubbles.

    PubMed

    Ghadimkhani, Aliasghar; Zhang, Wen; Marhaba, Taha

    2016-03-01

    Ceramic membranes are among the most promising technologies for membrane applications, owing to their excellent resistance to mechanical, chemical, and thermal stresses. However, membrane fouling is still an issue that hampers the applications at large scales. Air Nano Bubbles (NBs), due to high mass transfer efficiency, could potentially prevent fouling of ceramic membrane filtration processes. In this study, bench and pilot scale ceramic membrane filtration was performed with air NBs to resist fouling. To simulate fouling, humic acid, as an organic foulant, was applied to the membrane flat sheet surface. Complete membrane clogging was achieved in less than 6 h. Membrane defouling (cleaning) was performed by directly feeding of air NBs to the membrane cells. The surface of the ceramic membrane was superbly cleaned by air NBs, as revealed by atomic force microscope (AFM) images before and after the treatment. The permeate flux recovered to its initial level (e.g., 26.7 × 10(-9) m(3)/m(2)/s at applied pressure of 275.8 kPa), which indicated that NBs successfully unclogged the pores of the membrane. The integrated ceramic membrane and air NBs system holds potential as an innovative sustainable technology. Copyright © 2015 Elsevier Ltd. All rights reserved.

  19. Visual Schedule System in Dental Care for Patients with Autism: A Pilot Study.

    PubMed

    Mah, Janet Wt; Tsang, Phoebe

    A pilot study to test whether a visual schedule system using picture communication symbols can help children with autism have successful routine dental cleaning visits. 14 boys with autism between three- to eight-years-old presented to the dental clinic for four weekly consecutive dental appointments. Patients were randomly assigned to either the control group who received the tell-show-do method (i.e., standard of care), or the test group who received the tell-show-do method plus the visual schedule system. Patients in the test group completed an average of 1.38 more steps, at 35.52 seconds per step faster, and with 18.7% lower levels of behavioral distress than those in the control group. The use of a visual schedule system, along with repeated weekly visits, showed some promise in helping children with autism successfully complete more steps, progress at a quicker rate, and exhibit lower levels of behavioral distress within a dental appointment, compared to a traditional tell-show-do approach.

  20. FIELD DEMONSTRATION OF PERVAPORATION FOR THE SEPARATION OF VOLATILE ORGANIC COMPOUNDS FROM A SURFACTANT-BASED SOIL REMEDIATION FLUID

    EPA Science Inventory

    As part of a Department of Defense project, the US Environmental Protection Agency was responsible for designing, building and field operating a pilot-scale pervaporation unit. The field site ws an active dry cleaning facility on the grounds of Marine Corps Base Camp Lejeune in J...

  1. PRESS RELEASE IMAGE - STS-1 - CREW ACTIVITIES

    NASA Image and Video Library

    1981-04-12

    S81-30422 (12-14 April 1981) --- Astronaut John W. Young, STS-1 commander, cleans off his razor after shaving his face on the middeck of the space shuttle orbiter Columbia. A food tray can be seen mounted on a locker door at right. This 35mm frame was exposed by astronaut Robert L. Crippen, pilot. Photo credit: NASA

  2. EDIN-USVI Clean Energy Quarterly: Volume 1, Issue 3, September 2011 (Newsletter)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    2011-09-01

    This quarterly newsletter provides timely news and information about the plans and progress of the Energy Development in Island Nations-U.S. Virgin Islands pilot project, including significant events and milestones, work undertaken by each of the five working groups, and project-related renewable energy and energy efficiency educational outreach and technology deployment efforts.

  3. EVALUATION OF THE IMPACT OF CHLORINE ON MERCURY OXIDATION IN A PILOT-SCALE COAL COMBUSTION--THE EFFECT OF COAL BLENDING

    EPA Science Inventory

    Coal-fired power plants are a major source of mercury (Hg) released into the environment and the utility industry is currently investigating options to reduce Hg emissions. The EPA Clean Air Mercury Rule (CAMR) depends heavily on the co-benefit of mercury removal by existing and ...

  4. A pilot-scale nonwoven roll goods manufacturing process reduces microbial burden to pharmacopeia acceptance levels for nonsterile hygiene applications

    USDA-ARS?s Scientific Manuscript database

    A total of seven source fiber types were selected for use in the manufacturing of nonwoven roll goods: polyester; polypropylene; rayon; greige cotton from two sources; mechanically cleaned greige cotton; and scoured and bleached cotton. The microbial burden of each source fiber was measured as a pr...

  5. If I do not have enough water, then how could I bring additional water for toilet cleaning?! Addressing water scarcity to promote hygienic use of shared toilets in Dhaka, Bangladesh.

    PubMed

    Saxton, Ronald E; Yeasmin, Farzana; Alam, Mahbub-Ul; Al-Masud, Abdullah; Dutta, Notan Chandra; Yeasmin, Dalia; Luby, Stephen P; Unicomb, Leanne; Winch, Peter J

    2017-09-01

    Provision of toilets is necessary but not sufficient to impact health as poor maintenance may impair toilet function and discourage their consistent use. Water in urban slums is both scarce and a prerequisite for toilet maintenance behaviours. We describe the development of behaviour change communications and selection of low-cost water storage hardware to facilitate adequate flushing among users of shared toilets. We conducted nine focus group discussions and six ranking exercises with adult users of shared toilets (50 females, 35 males), then designed and implemented three pilot interventions to facilitate regular flushing and improve hygienic conditions of shared toilets. We conducted follow-up assessments 1 and 2 months post-pilot including nine in-depth interviews and three focus group discussions with adult residents (23 females, 15 males) and three landlords in the pilot communities. Periodic water scarcity was common in the study communities. Residents felt embarrassed to carry water for flushing. Reserving water adjacent to the shared toilet enabled slum residents to flush regularly. Signs depicting rules for toilet use empowered residents and landlords to communicate these expectations for flushing to transient tenants. Residents in the pilot reported improvements in cleanliness and reduced odour inside toilet cubicles. Our pilot demonstrates the potential efficacy of low-cost water storage and behaviour change communications to improve maintenance of and user satisfaction with shared toilets in urban slum settings. © 2017 John Wiley & Sons Ltd.

  6. Catalytic conversion wood syngas to synthetic aviation turbine fuels over a multifunctional catalyst

    Treesearch

    Qiangu Yan; Fei Yu; Jian Liu; Jason Street; Jinsen Gao; Zhiyong Cai; Jilei Zhang

    2013-01-01

    A continuous process involving gasification, syngas cleaning, and Fischer–Tropsch (FT) synthesis was developed to efficiently produce synthetic aviation turbine fuels (SATFs). Oak-tree wood chips were first gasified to syngas over a commercial pilot plant downdraft gasifier. The raw wood syngas contains about 47% N2, 21% CO, 18% H2...

  7. Ethanol production in a membrane bioreactor: pilot-scale trials in a corn wet mill.

    PubMed

    Escobar, J M; Rane, K D; Cheryan, M

    2001-01-01

    Pilot plant trials were conducted in a corn wet mill with a 7000-L membrane recycle bioreactor (MRB) that integrated ceramic microfiltration membranes in a semi-closed loop configuration with a stirred-tank reactor. Residence times of 7.5-10 h with ethanol outputs of 10-11.5% (v/v) were obtained when the cell concentration was 60-100 g/L dry wt of yeast, equivalent to about 10(9)-10(10) cells/mL. The performance of the membrane was dependent on the startup mode and pressure management techniques. A steady flux of 70 L/(m2 x h) could be maintained for several days before cleaning was necessary. The benefits of the MRB include better productivity; a clear product stream containing no particulates or yeast cells, which should improve subsequent stripping and distillation operations; and substantially reduced stillage handling. The capital cost of the MRB is $21-$34/(m3 x yr) ($0.08-$0.13/[gal x yr]) of ethanol capacity. Operating cost, including depreciation, energy, membrane replacement, maintenance, labor, and cleaning, is $4.5-9/m3 ($0.017-$0.034/gal) of ethanol.

  8. Optimising the operation of a MBR pilot plant by quantitative analysis of the membrane fouling mechanism.

    PubMed

    Jiang, T; Kennedy, M D; Guinzbourg, B F; Vanrolleghem, P A; Schippers, J C

    2005-01-01

    In order to optimize some operational conditions of MBR systems, a MBR pilot plant equipped with a submerged hollow fibre membrane module was employed in this study. The pilot MBR was fed with real municipal wastewater and the filtration flux, backwashing interval, aeration frequency and temperature were varied. A filtration flux below 25 I/m2h is generally recommended, at below this flux, the MBR operated at sub-critical flux conditions, the filter cake was minimized and membrane fouling was mainly attributed to the membrane pore blocking. Moreover, the membrane fouling, at below 25 I/m2h, was more reversible to backwashing; above this value, backwashing became less efficient to clean the membrane. Less frequent backwashing (e.g. 600 s filtration/45 s backwashing) decreased the amount of fouling irreversible to backwashing and its performance was superior to that of frequent backwashing (e.g. 200 s filtration/15 s backwashing). The MBR suffered more fouling at low temperature conditions (e.g. at 13-14 degrees C) than at high temperature conditions (e.g. at 17-18 degrees C). A conceptual model was built up and successfully interpreted this temperature effect.

  9. Impact of PAC Fines in Fouling of Polymeric and Ceramic Low-Pressure Membranes for Drinking Water Treatment

    PubMed Central

    Oligny, Laurent; Bérubé, Pierre R.; Barbeau, Benoit

    2016-01-01

    This study assessed the issue of membrane fouling in a Hybrid Membrane Process (HMP) due to the export of powdered activated carbon (PAC) fines from a pretreatment contactor. Two parallel pilot-scale ceramic and polymeric membranes were studied. Reversible and irreversible foulings were measured following three cleaning procedures: Physical backwashing (BW), chemically enhanced backwashing (CEB) and Clean-in-Place (CIP). The impacts on fouling of membrane type, operation flux increase and the presence/absence of the PAC pretreatment were investigated. Membranes without pretreatment were operated in parallel as a control. In addition, CIP washwaters samples were analyzed to measure organic and inorganic foulants removed from the membranes. It was observed that for the polymeric membranes, fouling generally increased with the presence of the PAC pretreatment because of the export of fines. On the contrary, the ceramic membranes were not significantly impacted by their presence. The analysis of CIP washwaters showed a greater total organic carbon (TOC) content on membranes with a PAC pretreatment while no similar conclusion could be made for inorganic foulants. PMID:27399788

  10. Impact of PAC Fines in Fouling of Polymeric and Ceramic Low-Pressure Membranes for Drinking Water Treatment.

    PubMed

    Oligny, Laurent; Bérubé, Pierre R; Barbeau, Benoit

    2016-07-07

    This study assessed the issue of membrane fouling in a Hybrid Membrane Process (HMP) due to the export of powdered activated carbon (PAC) fines from a pretreatment contactor. Two parallel pilot-scale ceramic and polymeric membranes were studied. Reversible and irreversible foulings were measured following three cleaning procedures: Physical backwashing (BW), chemically enhanced backwashing (CEB) and Clean-in-Place (CIP). The impacts on fouling of membrane type, operation flux increase and the presence/absence of the PAC pretreatment were investigated. Membranes without pretreatment were operated in parallel as a control. In addition, CIP washwaters samples were analyzed to measure organic and inorganic foulants removed from the membranes. It was observed that for the polymeric membranes, fouling generally increased with the presence of the PAC pretreatment because of the export of fines. On the contrary, the ceramic membranes were not significantly impacted by their presence. The analysis of CIP washwaters showed a greater total organic carbon (TOC) content on membranes with a PAC pretreatment while no similar conclusion could be made for inorganic foulants.

  11. Quiet Clean Short-haul Experimental Engine (QCSEE) under-the-wing engine digital control system design report

    NASA Technical Reports Server (NTRS)

    1978-01-01

    A digital electronic control was combined with conventional hydromechanical components to operate the four controlled variables on the under-the-wing engine: fuel flow, fan blade pitch, fan exhaust area, and core compressor stator angles. The engine and control combination offers improvements in noise, pollution, thrust response, operational monitoring, and pilot workload relative to current engines.

  12. Innovative Commercialization Efforts Underway at the National Renewable Energy Laboratory

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cheesbrough, Kate; Bader, Meghan

    New clean energy and energy efficiency technology solutions hold the promise of significant reductions in energy consumption. However, proven barriers for these technologies, including the technological and commercialization valleys of death, result in promising technologies falling to the wayside. To address these gaps, NREL's Innovation & Entrepreneurship Center designs and manages advanced programs aimed at supporting the development and commercialization of early stage clean energy technologies with the goal of accelerating new technologies to market. These include: Innovation Incubator (IN2) in partnership with Wells Fargo: this technology incubator supports energy efficiency building-related startups to overcome market gaps by providing accessmore » to technical support at NREL; Small Business Voucher Pilot: this program offers paid vouchers for applicants to access a unique skill, capability, or facility at any of the 17 DOE National Laboratories to bring next-generation clean energy technologies to market; Energy Innovation Portal: NREL designed and developed the Energy Innovation Portal, providing access to EERE focused intellectual property available for licensing from all of the DOE National Laboratories; Lab-Corps: Lab-Corps aims to better train and empower national lab researchers to understand market drivers and successfully transition their discoveries into high-impact, real world technologies in the private sector; Incubatenergy Network: the Network provides nationwide coordination of clean energy business incubators, share best practices, support clean energy entrepreneurs, and help facilitate a smoother transition to a more sustainable clean energy economy; Industry Growth Forum: the Forum is the perfect venue for clean energy innovators to maximize their exposure to receptive capital and strategic partners. Since 2003, presenting companies have collectively raised more than $5 billion in growth financing.« less

  13. Removal of odor using biofilter from duck confinement buildings.

    PubMed

    Lau, Anthony; Cheng, Kimberly

    2007-06-01

    The poultry and waterfowl industry in the Fraser Valley of British Columbia needs to deal with odor emission problems. The objective of this study is to evaluate the performance of a pilot-scale biofiltration system for treating odors from the exhaust air streams of a commercial duck farm building before their release to the atmosphere. A pilot-scale biofiltration system with semi-enclosed wooden structure was designed, constructed and installed to treat the exhaust air from one of the 12 operating ventilation exhaust fans, having a ventilation rate of 2.36 m3/s. The empty bed residence time of the biofilter was 5-10 seconds at the design flow rate. The biofilter media comprised of 2 parts softwood chips and barks to 1 part finished compost. Fabric filters were used for pre-treatment to protect the biofilter from clogging by dust particles and feathers. Odor reduction was determined by measuring the concentration of the air entering and leaving the biofilter via olfactometry analysis. The odor concentration of untreated barn air was found to vary from 8553+/-1006 to 12171+/-1575 OU/m3; however, the odor concentration was substantially reduced to 420+/-195 OU/m(3) after the manure storage was cleaned out at the end of summer. The odor removal efficiency of the biofilter system averaged 95+/-3%. The high frequency of cleaning and replacement required of the fabric filters would considerably increase the operating cost. Alternative methods of dust and odor removal that are more cost-effective will need to be investigated in the future.

  14. Bathymetry and selected perspective views of 6 reef and coastal areas in Northern Lake Michigan

    USGS Publications Warehouse

    Barnes, Peter; Fleisher, Guy; Gardner, James V.; Lee, Kristen

    2003-01-01

    We apply state of the art laser technology and derivative imagery to map the detailed morphology and of principal lake trout spawning sites on reefs in Northern Lake Michigan and to provide a geologic interpretation. We sought to identify the presence of ideal spawning substrate: shallow, "clean" gravel/cobble substrate, adjacent to deeper water. This study is a pilot collaborative effort with the US Army Corps of Engineers SHOALS (Scanning Hydrographic Operational Airborne Lidar Survey) program. The high-definition maps are integrated with known and developing data on fisheries, as well as limited substrate sedimentologic information and underlying Paleozoic carbonate rocks.

  15. A covalently cross-linked gel derived from the epidermis of the pilot whale Globicephala melas.

    PubMed

    Baum, C; Fleischer, L-G; Roessner, D; Meyer, W; Siebers, D

    2002-01-01

    The rheological properties of the stratum corneum of the pilot whale (Globicephala melas) were investigated with emphasis on their significance to the self-cleaning abilities of the skin surface smoothed by a jelly material enriched with various hydrolytic enzymes. The gel formation of the collected fluid was monitored by applying periodic-harmonic oscillating loads using a stress-controlled rheometer. In the mechanical spectrum of the gel, the plateau region of the storage modulus G' (<1200 Pa) and the loss modulus G" (>120 Pa) were independent of frequency (omega = 43.98 to 0.13 rad x s(-1), tau = 15 Pa, T = 20 degrees C), indicating high elastic performance of a covalently cross-linked viscoelastic solid. In addition, multi-angle laser light scattering experiments (MALLS) were performed to analyse the potential time-dependent changes in the weight-average molar mass of the samples. The observed increase showed that the gel formation is based on the assembly of covalently cross-linked aggregates. The viscoelastic properties and the shear resistance of the gel assure that the enzyme-containing jelly material smoothing the skin surface is not removed from the stratum corneum by shear regimes during dolphin jumping. The even skin surface is considered to be most important for the self-cleaning abilities of the dolphin skin against biofouling.

  16. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jacob, Andria; Cyr, Shirley

    In April 2010, the City of Portland received a $20 million award from the U.S. Department of Energy, as part of the Energy Efficiency and Conservation Block Grant program. This award was appropriated under the American Recovery and Reinvestment Act (ARRA), passed by President Obama in 2009. DOE’s program became known as the Better Buildings Neighborhood Program (BBNP). The BBNP grant objectives directed the City of Portland Bureau of Planning and Sustainability (BPS) as the primary grantee to expand the BPS-led pilot program, Clean Energy Works Portland, into Clean Energy Works Oregon (CEWO), with the mission to deliver thousands ofmore » home energy retrofits, create jobs, save energy and reduce carbon dioxide emissions.The Final Technical Report explores the successes and lessons learned from the first 3 years of program implementation.« less

  17. Hydrodynamics of high solids anaerobic reactor: Characterization of solid segregation and liquid mixing pattern in a pilot plant VALORGA facility under different reactor geometry.

    PubMed

    Álvarez, C; Colón, J; Lópes, A C; Fernández-Polanco, M; Benbelkacem, H; Buffière, P

    2018-06-01

    One of the main problems of dry anaerobic digestion plants treating urban solid waste is the loss of useful volume by the sedimentation of solids (inerts) into the bottom of the digester, or by accumulation of floating materials in its upper part. This entails a periodic cost of emptying and cleaning the digesters, a decrease in biogas production and complications in maintenance. Usually the sedimentation is a consequence of the heterogeneity of waste that, in addition to organic matter, drags particles of high density that end up obstructing the digesters. To reduce this bottleneck, URBASER has designed a new configuration of VALORGA reactor. That is, the VALORGA central wall has been removed and an inclined bottom has been added. To test the sedimentability and the overall performance of both configurations (current and new design), hydrodynamic tests have been carried out in a pilot digester (digester of 95 m 3 capacity). To simulate the liquid phase and the solid phase of the reactor, lithium tracers and tags of different densities with RFID (radio frequency identification reader) have been used respectively. The results of the study showed an improvement in the performance of the new reactor design at pilot level. Copyright © 2018 Elsevier Ltd. All rights reserved.

  18. Energy Efficiency Finance Programs: Use Case Analysis to Define Data Needs and Guidelines

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Thompson, Peter; Larsen, Peter; Kramer, Chris

    There are over 200 energy efficiency loan programs—across 49 U.S. states—administered by utilities, state/local government agencies, or private lenders.1 This distributed model has led to significant variation in program design and implementation practices including how data is collected and used. The challenge of consolidating and aggregating data across independently administered programs has been illustrated by a recent pilot of an open source database for energy efficiency financing program data. This project was led by the Environmental Defense Fund (EDF), the Investor Confidence Project, the Clean Energy Finance Center (CEFC), and the University of Chicago. This partnership discussed data collection practicesmore » with a number of existing energy efficiency loan programs and identified four programs that were suitable and willing to participate in the pilot database (Diamond 2014).2 The partnership collected information related to ~12,000 loans with an aggregate value of ~$100M across the four programs. Of the 95 data fields collected across the four programs, 30 fields were common between two or more programs and only seven data fields were common across all programs. The results of that pilot study illustrate the inconsistencies in current data definition and collection practices among energy efficiency finance programs and may contribute to certain barriers.« less

  19. Investigation of image enhancement techniques for the development of a self-contained airborne radar navigation system

    NASA Technical Reports Server (NTRS)

    Phatak, A. V.; Karmali, M. S.

    1983-01-01

    This study was devoted to an investigation of the feasibility of applying advanced image processing techniques to enhance radar image characteristics that are pertinent to the pilot's navigation and guidance task. Millimeter (95 GHz) wave radar images for the overwater (i.e., offshore oil rigs) and overland (Heliport) scenario were used as a data base. The purpose of the study was to determine the applicability of image enhancement and scene analysis algorithms to detect and improve target characteristics (i.e., manmade objects such as buildings, parking lots, cars, roads, helicopters, towers, landing pads, etc.) that would be helpful to the pilot in determining his own position/orientation with respect to the outside world and assist him in the navigation task. Results of this study show that significant improvements in the raw radar image may be obtained using two dimensional image processing algorithms. In the overwater case, it is possible to remove the ocean clutter by thresholding the image data, and furthermore to extract the target boundary as well as the tower and catwalk locations using noise cleaning (e.g., median filter) and edge detection (e.g., Sobel operator) algorithms.

  20. Market assessment of PFBC ash use

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bland, A. E.; Brown, T. H., Western Research Institute

    1998-01-01

    Pressurized fluidized bed combustion (PFBC) of coal is undergoing demonstration in the United States, as well as throughout the world. American Electric Power`s (AEP`s) bubbling PFBC 70 MWe Tidd demonstration program in Ohio and pilot-scale development at Foster Wheeler Energia Oy 10 MWth circulating PFBC at Karhula, Finland, have demonstrated the advantages of PFBC technology. Further technology development in the US is planned with the deployment of the technology at the MacIntosh Clean Coal project in Lakeland, Florida. Development of uses for solid wastes from PFBC coal-fired power systems is being actively pursued as part of the demonstration of PFBCmore » technologies. Ashes collected from Foster Wheeler Energia Oy pilot circulating PFBC tests in Karhula, Finland, operating on (1) low sulfur subbituminous and (2) high sulfur bituminous coal; and ash from the AEP`s high-sulfur bituminous coal-fired bubbling PFBC in Brilliant, Ohio, were evaluated in laboratory and pilot-scale ash use testing at Western Research Institute (WRI).« less

  1. Separation of packaging plastics by froth flotation in a continuous pilot plant.

    PubMed

    Carvalho, Teresa; Durão, Fernando; Ferreira, Célia

    2010-11-01

    The objective of the research was to apply froth flotation to separate post-consumer PET (Polyethylene Terephthalate) from other packaging plastics with similar density, in a continuously operated pilot plant. A representative sample composed of 85% PET, 2.5% PVC (Polyvinyl Chloride) and 11.9% PS (Polystyrene) was subjected to a combination of alkaline treatment and surfactant adsorption followed by froth flotation. A mineral processing pilot plant, owned by a Portuguese mining company, was adapted for this purpose. The experimentation showed that it is possible to produce an almost pure concentrate of PET, containing 83% of the PET in feed, in a single bank of mechanical flotation cells. The concentrate grade attained was 97.2% PET, 1.1% PVC and 1.1% PS. By simulation it was shown that the Portuguese recycling industry specifications can be attained if one cleaning and one scavenger stages are added to the circuit. Copyright © 2010 Elsevier Ltd. All rights reserved.

  2. Knowledge Transfer Project: Cultivating Smart Energy Solutions through Dynamic Peer-to-Peer Learning

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    As energy policy makers and professionals convene in the Oresund region for the 9th Annual Clean Energy Ministerial (CEM9), the global community is as united as ever around the common goal of accelerating the transition to global clean energy. Through sustained collective effort and thought leadership, CEM partners and stakeholders are systematically addressing the barriers to the widescale deployment of clean energy technologies. Pivotal to their progress is the efficient sharing and dissemination of knowledge. To address that need, the CEM-initiative International SmartGrid Action Network (ISGAN) launched the Knowledge Transfer Project (KTP) in March 2016 to capture, collect, and sharemore » knowledge about smart grid technologies among countries and key stakeholders. Building on ISGAN's experience with delivering deep-dive workshops, the KTP fosters meaningful international dialogue on smart grids with a focus on developing competence and building capacity. After a successful 2016 pilot project and two consecutive projects, each with a different focus and structure, the KTP has become an established practice that can support existing ISGAN or CEM initiatives. To accommodate different purposes, needs, and practical circumstances, ISGAN has adopted three basic models for delivering KTP workshops: Country-Centric, Multilateral, and Hybrid. This fact sheet describes each approach through case studies of workshops in Mexico, India, and Belgium, and invites new ideas and partners for future KTPs.« less

  3. [Influence AquaLase at corneal endothelial cells].

    PubMed

    Jirásková, N; Rozsíval, P; Ludvíková, M; Burova, M; Nekolová, J

    2009-07-01

    To assess the effect of the cleaning of the posterior capsule using pulses of balanced salt solution (BSS) on the corneal endothelial cells. This pilot study involves 43 patients with bilateral cataracts having lens removal using torsional phacoemulsification (Ozil, Infiniti, Alcon) and bimanul irrigation/aspiration (I/A). Posterior capsule of the right eye of each patient was cleaned using pulses of BSS (AquaLase, Infiniti, Alcon). Surgery was performed by one of 2 surgeons (NJ, PR), both eyes of each patient was operated on by the same surgeon. Best corrected visual acuity (BCVA), endotelial cell count and pachymetry were evaluated pre- and postoperatively as well as occurence af peri- and postoperative complications. Preoperative mean pachymetry (P) was 566 +/- 45 microm in the right eye (RE) and 562 +/- 42 microm in the left eye (LE), mean endotelial cell count (ECC) 2541 +/- 317 cells/mm2 (RE) and 2567 +/- 311 cells/mm2 (LE). Three months after surgery P was 557 +/- 43 microm (RE) and 558 +/- 45 microm (LE) and ECC 2368 +/- 416 cells/mm2 (RE) and 2396 +/- 417 cells/mm2 (LE). There was no statistical difference in postoperative changes of both corneal parameters between right and left eyes. Best corrected visual acuity improved in all eyes and no peri-or postoperative complications occured. Cleaning of the posterior capsule using AquaLase is safe for corneal endothelial cells.

  4. Petroleum contaminated water and health symptoms: a cross-sectional pilot study in a rural Nigerian community.

    PubMed

    Kponee, Kalé Zainab; Chiger, Andrea; Kakulu, Iyenemi Ibimina; Vorhees, Donna; Heiger-Bernays, Wendy

    2015-11-06

    The oil-rich Niger Delta suffers from extensive petroleum contamination. A pilot study was conducted in the region of Ogoniland where one community, Ogale, has drinking water wells highly contaminated with a refined oil product. In a 2011 study, the United Nations Environment Programme (UNEP) sampled Ogale drinking water wells and detected numerous petroleum hydrocarbons, including benzene at concentrations as much as 1800 times higher than the USEPA drinking water standard. UNEP recommended immediate provision of clean drinking water, medical surveillance, and a prospective cohort study. Although the Nigerian government has provided emergency drinking water, other UNEP recommendations have not been implemented. We aimed to (i) follow up on UNEP recommendations by investigating health symptoms associated with exposure to contaminated water; and (ii) assess the adequacy and utilization of the government-supplied emergency drinking water. We recruited 200 participants from Ogale and a reference community, Eteo, and administered questionnaires to investigate water use, perceived water safety, and self-reported health symptoms. Our multivariate regression analyses show statistically significant associations between exposure to Ogale drinking water and self-reported health symptoms consistent with petroleum exposure. Participants in Ogale more frequently reported health symptoms related to neurological effects (OR = 2.8), hematological effects (OR = 3.3), and irritation (OR = 2.7). Our results are the first from a community relying on drinking water with such extremely high concentrations of benzene and other hydrocarbons. The ongoing exposure and these pilot study results highlight the need for more refined investigation as recommended by UNEP.

  5. Handheld computers for survey and trial data collection in resource-poor settings: development and evaluation of PDACT, a Palm Pilot interviewing system.

    PubMed

    Seebregts, Christopher J; Zwarenstein, Merrick; Mathews, Catherine; Fairall, Lara; Flisher, Alan J; Seebregts, Clive; Mukoma, Wanjiru; Klepp, Knut-Inge

    2009-11-01

    Handheld computers (personal digital assistant, PDA) have the potential to reduce the logistic burden, cost, and error rate of paper-based health research data collection, but there is a lack of appropriate software. The present work describes the development and evaluation of PDACT, a Personal Data Collection Toolset (www.healthware.org/pdact/index.htm) for the Palm Pilot handheld computer for interviewer-administered and respondent-administered data collection. We developed Personal Data Collection Toolkit (PDACT) software to enable questionnaires developed in QDS Design Studio, a Windows application, to be compiled and completed on Palm Pilot devices and evaluated in several representative field survey settings. The software has been used in seven separate studies and in over 90,000 interviews. Five interviewer-administered studies were completed in rural settings with poor communications infrastructure, following one day of interviewer training. Two respondent-administered questionnaire studies were completed by learners, in urban secondary schools, after 15min training. Questionnaires were available on each handheld in up to 11 languages, ranged from 20 to 580 questions, and took between 15 and 90min to complete. Up to 200 Palm Pilot devices were in use on a single day and, in about 50 device-years of use, very few technical problems were found. Compared with paper-based collection, data validation and cleaning times were reduced, and fewer errors were found. PDA data collection is easy to use and preferred by interviewers and respondents (both respondent-administered and interviewer-administered) over paper. Data are compiled and available within hours of collection facilitating data quality assurance. Although hardware increases the setup cost of the first study, the cumulative cost falls thereafter, and converges on the cumulative cost of paper-based studies (four, in the case of our interviewer-administered studies). Handheld data collection is an appropriate, affordable and convenient technology for health data collection, in diverse settings.

  6. Biomass properties and permeability in an immersed hollow fibre membrane bioreactor at high sludge concentrations.

    PubMed

    Wang, Z Z; Zsirai, T; Connery, K; Fabiyi, M; Larrea, A; Li, J; Judd, S J

    2014-01-01

    This study aimed to investigate the influence of biomass properties and high mixed liquor suspended solids (MLSS) concentrations on membrane permeability in a pilot-scale hollow fibre membrane bioreactor treating domestic wastewater. Auxiliary molasses solution was added to maintain system operation at constant food-to-microorganisms ratio (F/M = 0.13). Various physicochemical and biological biomass parameters were measured throughout the trial, comprising pre-thickening, thickening and post-thickening periods with reference to the sludge concentration and with aerobic biotreatment continuing throughout. Correlations between dynamic changes in biomass characteristics and membrane permeability decline as well as permeability recovery were further assessed by statistical analyses. Results showed the MLSS concentration to exert the greatest influence on sustainable membrane permeability, with a weaker correlation with particle size distribution. The strong dependence of absolute recovered permeability on wet accumulated solids (WACS) concentration, or clogging propensity, revealed clogging to deleteriously affect membrane permeability decline and recovery (from mechanical declogging and chemical cleaning), with WACS levels increasing with increasing MLSS. Evidence from the study indicated clogging may permanently reduce membrane permeability post declogging and chemical cleaning, corroborating previously reported findings.

  7. Does Flooring Substrate Impact Kennel and Dog Cleanliness in Commercial Breeding Facilities?

    PubMed

    Stella, Judith; Hurt, Moriah; Bauer, Amy; Gomes, Paulo; Ruple, Audrey; Beck, Alan; Croney, Candace

    2018-04-21

    Evaluation of kennel flooring surfaces is needed to understand their impacts on dog health and well-being. This pilot study aimed to characterize aspects of physical health, kennel cleanliness, and dog body cleanliness on flooring types common in US breeding kennels. Subjects were 118 adult dogs housed on diamond-coated expanded metal (DCEM), polypropylene (POLY), or concrete (CON) flooring at five commercial breeding facilities in Indiana, U.S. Body condition, paw, elbow, and hock health scores were recorded. Each indoor kennel and dog was visually assessed for cleanliness. Kennels were swabbed immediately after cleaning with electrostatic dry cloths and cultured for Escherichia coli . Descriptive statistics were used for analysis. Mean body condition score (BCS), kennel and dog cleanliness scores were all near ideal (3, 1.15, and 1.04, respectively). Thirty-one percent or fewer kennels at each facility were culture-positive for E. coli after cleaning. No serious paw, elbow, or hock problems were identified. Overall, the findings indicate that with appropriate management and regular access to additional surfaces, dog foot health, cleanliness, and kennel cleanliness can be maintained on the flooring types investigated.

  8. Chemicals to help coal come clean

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Thayer, A.M.

    Scrubbing methods to capture carbon from power plants are advancing to the demonstration phase. The article gives an update of projects around the world, and the goals and cost of CCS projects. BASF, together with RWE Power and Linde, are working to ensure state of the art integration of the carbon-capture process into a power plant to minimize the penalty in electrical output. A pilot project will test new solvents in an 'advanced amine' system at RWE's power station in Niederaussem, Germany. A pilot unit will soon capture CO{sub 2} from a coal-fired plant of Dow's in South Charleston, WV,more » USA and Dow has also agreed to build an amines demonstration facility in Belchatow, Poland. Other projects in the USA and Canada are reported. 1 fig.« less

  9. Advanced in-duct sorbent injection for SO{sub 2} control. Final technical report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stouffer, M.R.; Withium, J.A.; Rosenhoover, W.A.

    1994-12-01

    The objective of this research project was to develop a second generation duct sorbent injection technology as a cost-effective compliance option for the 1990 Clean Air Act Amendments. Research and development work was focused on the Advanced Coolside process, which showed the potential for exceeding the original performance targets of 90% SO{sub 2} removal and 60% sorbent utilization. Process development was conducted in a 1000 acfm pilot plant. The pilot plant testing showed that the Advanced Coolside process can achieve 90% SO{sub 2} removal at sorbent utilizations up to 75%. The testing also showed that the process has the potentialmore » to achieve very high removal efficiency (90 to >99%). By conducting conceptual process design and economic evaluations periodically during the project, development work was focused on process design improvements which substantially lowered process capital and operating costs, A final process economic study projects capital costs less than one half of those for limestone forced oxidation wet FGD. Projected total SO{sub 2} control cost is about 25% lower than wet FGD for a 260 MWe plant burning a 2.5% sulfur coal. A waste management study showed the acceptability of landfill disposal; it also identified a potential avenue for by-product utilization which should be further investigated. Based on the pilot plant performance and on the above economic projections, future work to scale up the Advanced Coolside process is recommended.« less

  10. The GreenLab Research Facility: A Micro-Grid Integrating Production, Consumption and Storage of Clean Energy

    NASA Technical Reports Server (NTRS)

    McDowell Bomani, Bilal Mark; Elbuluk, Malik; Fain, Henry; Kankam, Mark D.

    2012-01-01

    There is a large gap between the production and demand for energy from alternative fuel and alternative renewable energy sources. The NASA Glenn Research Center (GRC) has initiated a laboratory-pilot study that concentrates on using biofuels as viable alternative fuel resources for the field of aviation, as well as, utilizing wind and solar technologies as alternative renewable energy resources, and in addition, the use of pumped water for storage of energy that can be retrieved through hydroelectric generation. This paper describes the GreenLab Research Facility and its power and energy sources with .recommendations for worldwide expansion and adoption of the concept of such a facility

  11. Hybrid coagulation-UF processes for spent filter backwash water treatment: a comparison studies for PAFCl and FeCl3 as a pre-treatment.

    PubMed

    Ebrahimi, Afshin; Amin, Mohammad Mehdi; Pourzamani, Hamidreza; Hajizadeh, Yaghoub; Mahvi, Amir Hossein; Mahdavi, Mokhtar; Rad, Mohammad Hassan Rabie

    2017-08-01

    In this study, the reclamation of clean water from spent filter backwash water (SFBW) was investigated through pilot-scale experiments. The pilot plant consisted of pre-sedimentation, coagulation, flocculation, clarification, and ultrafiltration (UF). Two coagulants of PAFCl and FeCl 3 were investigated with respect to their performance on treated SFBW quality and UF membrane fouling. At the optimum dose of PAFCl and FeCl 3 turbidity removal of 99.6 and 99.4% was attained, respectively. PAFCl resulted in an optimum UV 254 , TOC, and DOC removal of 80, 83.6, and 72.7%, respectively, and FeCl 3 caused the removal of those parameters by 76.7, 80.9, and 65.9%, respectively. PAFCl removed hydrophilic and transphilic constituent better than FeCl 3 , but FeCl 3 had, to some extent, higher affinities to a hydrophobic fraction. It was concluded that PAFCl showed a better coagulation performance in most cases and caused a lower membrane fouling rate compared to FeCl 3 . Finally, the treated SFBW with both coagulant-UF systems met the drinking water standards.

  12. Pilot-scale testing membrane bioreactor for wastewater reclamation in industrial laundry.

    PubMed

    Andersen, M; Kristensen, G H; Brynjolf, M; Grüttner, H

    2002-01-01

    A pilot-scale study of membrane bioreactor treatment for reclamation of wastewater from Berendsen Textile Service industrial laundry in Søborg, Denmark was carried out over a 4 month period. A satisfactory COD degradation was performed resulting in a low COD in the permeate (< 50 mg/l). To obtain satisfactory treatment, addition of nitrogen was necessary. The biodegradability of the permeate was very low (BOD5 < 2 mg/l). A hydraulic retention time of 1 d turned out to be sufficient at a sludge concentration of 10 g MLSS/l. Through addition of a cationic polymer, a satisfactory dewaterability of the sludge was reached. Membrane tests showed that operating at a trans-membrane pressure of 3 bar and a cross-flow velocity of 4 m/s, a flux of 120 l/m2h can be expected without using chemicals for membrane cleaning. The quality of the permeate was very good when comparing to the reuse quality demands of water to the wash processes. Reuse of the permeate in all rinsing steps requires additional treatment through reverse osmosis.

  13. Pilot-Scale Test of Dephosphorization in Steelmaking Using Red Mud-Based Flux

    NASA Astrophysics Data System (ADS)

    Li, Fengshan; Zhang, Yanling; Guo, Zhancheng

    2017-09-01

    Bayer red mud is characterized by its highly oxidizing nature and high alkalinity. It can act as an ideal flux and dephosphorizer in steelmaking. In this study, pilot-scale tests applying the Bayer red mud-based flux in steelmaking have been conducted in a 200-kg, medium-frequency induction furnace. Good slag fluidity and no rephosphorization phenomena are observed. High dephosphorization rates ( 90%) and low final [P] (<0.02%) are obtained in the situation of high [C] of 2.0-3.0%, which are of great importance for the production of clean steel. The P2O5 content in the P-rich phase in the red mud-based slag can reach as high as 34.05 wt.%, far higher than the 6.73 wt.% in ordinary industrial slag. This suggests that the Al2O3, TiO2 in Bayer red mud can enhance the solid solubility of phosphorus in the P-rich phase. The data obtained are important for promoting the large-scale application of red mud in steelmaking.

  14. Pilot Plant Testing of Hot Gas Building Decontamination Process

    DTIC Science & Technology

    1987-10-30

    last hours of the cooldown (after water traps in the line were installed) showed no detectable contamination from this station. 1 60 CwC -So 0) 0 o j...Since we will not require refrigeration, additional generators probably 0 qlill not be required. Water is trucked to the site. Agent contaminated water ...surface. The gauze was handled by forceps during all of the sampling steps to prevent contamination after the solvent extraction clean-up of the gauze pads

  15. Addressing reverse osmosis fouling within water reclamation--a side-by-side comparison of low-pressure membrane pretreatments.

    PubMed

    Kent, Fraser C; Farahbakhsh, Khosrow

    2011-06-01

    A tertiary membrane filtration (TMF) pilot operating on secondary effluent and a membrane bioreactor (MBR) were setup in a side-by-side study as pretreatments for two identical reverse osmosis pilot systems. The water quality of the permeate from both low-pressure membrane pretreatment systems and the fouling rate of the reverse osmosis systems were compared to assess the capabilities of the two low-pressure membrane pretreatments to prevent organic fouling of the reverse osmosis systems. Both pretreatment pilots were setup using typical operating conditions (i.e., solids retention time and mixed-liquor suspended solids). A consistent difference in water quality and reverse osmosis performance was demonstrated during the 12-month study. The MBR permeate consistently had significantly lower total organic carbon (TOC) and chemical oxygen demand concentrations, but higher color and specific UV absorbance compared with the permeate from the TMF pretreatment. The pretreatment with the MBR gave an average reverse osmosis fouling rate over the entire study (0.27 Lmh/bar.month) that was less than half of the value found for the reverse osmosis with TMF pretreatment (0.60 Lmh/bar.month). A correlation of reverse osmosis feed TOC concentration with average reverse osmosis fouling rate also was established, independent of the pretreatment method used. Results from a cleaning analysis, energy dispersive spectroscopy, and fourier transformed infrared reflectometry confirmed that the foulants were primarily organic in nature. It is concluded that, for this type of application and setup, MBR systems present an advantage over tertiary membrane polishing of secondary effluent for reverse osmosis pretreatment.

  16. Arsenic Remediation Enhancement Through Chemical Additions to Pump and Treat Operations

    NASA Astrophysics Data System (ADS)

    Wovkulich, K.; Mailloux, B. J.; Stute, M.; Simpson, H. J.; Keimowitz, A. R.; Powell, A.; Lacko, A.; Chillrud, S. N.

    2008-12-01

    Arsenic is a contaminant found at more than 500 US Superfund sites. Since pump and treat technologies are widely used for remediation of contaminated groundwater, increasing the efficiency of contaminant removal at such sites should allow limited financial resources to clean up more sites. The Vineland Chemical Company Superfund site is extensively contaminated with arsenic after waste arsenic salts were stored and disposed of improperly for much of the company's 44 year manufacturing lifetime. Despite approximately eight years of pump and treat remediation, arsenic concentrations in the recovery wells can still be greater than 1000 ppb. The arsenic concentrations in the groundwater remain high because of slow desorption of arsenic from contaminated aquifer solids. Extrapolation of laboratory column experiments suggest that continuing the current groundwater remediation practice based on flushing ambient groundwater through the system may require on the order of hundreds of years to clean the site. However, chemical additions of phosphate or oxalic acid into the aquifer could decrease the remediation time scale substantially. Laboratory results from a soil column experiment using input of 10 mM oxalic acid suggest that site clean up of groundwater could be decreased to as little as four years. Pilot scale forced gradient field experiments will help establish whether chemical additions can be effective for increasing arsenic mobilization from aquifer solids and thus substantially decrease pump and treat clean up time.

  17. Effect of mechanical cleaning with granular material on the permeability of submerged membranes in the MBR process.

    PubMed

    Siembida, B; Cornel, P; Krause, S; Zimmermann, B

    2010-07-01

    The research on fouling reduction and permeability loss in membrane bioreactors (MBRs) was carried out at two MBR pilot plants with synthetic and real wastewater. On the one hand, the effect of mechanical cleaning with an abrasive granular material on the performance of a submerged MBR process was tested. Additionally, scanning electron microscopy (SEM) measurements and integrity tests were conducted to check whether the membrane material was damaged by the granulate.The results indicate that the fouling layer formation was significantly reduced by abrasion using the granular material. This technique allowed a long-term operation of more than 600 days at a flux up to 40 L/(m2 h) without chemical cleaning of the membranes. Moreover, it was demonstrated that the membrane bioreactor (MBR) with granulate could be operated with more than 20% higher flux compared to a conventional MBR operation. SEM images and integrity tests showed that in consequence of abrasive cleaning, the granular material left brush marks on the membrane surface, however, the membrane function was not affected.In a parallel experimental set up, the impact of the operationally defined "truly soluble fraction" <0.04 microm from wastewater and activated sludge on the ultrafiltration membrane fouling characteristics was investigated. It was shown that the permeability loss was caused predominantly by the colloidal fraction >0.04 microm rather than by the dissolved fraction of wastewater and activated sludge.

  18. DEVELOPMENT, TESTING, AND DEMONSTRATION OF AN OPTIMAL FINE COAL CLEANING CIRCUIT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Steven R. Hadley; R. Mike Mishra; Michael Placha

    1999-01-27

    The objective of this project was to improve the efficiency of the fine coal froth flotation circuit in commercial coal preparation plants. The plant selected for this project, Cyprus Emerald Coal Preparation Plant, cleans 1200-1400 tph of Pittsburgh seam raw coal and uses conventional flotation cells to clean the minus 100-mesh size fraction. The amount of coal in this size fraction is approximately 80 tph with an average ash content of 35%. The project was carried out in two phases. In Phase I, four advanced flotation cells, i.e., a Jameson cell, an Outokumpu HG tank cell, an open column, andmore » a packed column cell, were subjected to bench-scale testing and demonstration. In Phase II, two of these flotation cells, the Jameson cell and the packed column, were subjected to in-plant, proof-of-concept (POC) pilot plant testing both individually and in two-stage combination in order to ascertain whether a two-stage circuit results in lower levelized production costs. The bench-scale results indicated that the Jameson cell and packed column cell would be amenable to the single- and two-stage flotation approach. POC tests using these cells determined that single-stage coal matter recovery (CMR) of 85% was possible with a product ash content of 5.5-7%. Two-stage operation resulted in a coal recovery of 90% with a clean coal ash content of 6-7.5%. This compares favorably with the plant flotation circuit recovery of 80% at a clean coal ash of 11%.« less

  19. New drainage tunnel of the tunnel Višňové - design and excavation

    NASA Astrophysics Data System (ADS)

    Jurík, Igor; Grega, Ladislav; Valko, Jozef; Janega, Peter

    2017-09-01

    The actual pilot tunnel dated to the period of geological and hydrogeological survey, is designed as a part of the tunnel Višňové, which is located at the section of the D1 motorway Lietavská Lúčka - Višňové - Dubná Skala in Slovakia. Drainage tunnel will be used for the drainage of the main tunnel tubes, where the maximum inflow from the eastern portal is greater than 250 l.s-1. Overlapping of the initial pilot tunnel with the profile of the southern tunnel tube led to the demolition of the portal sections of the pilot tunnel during the excavation of main tunnel tubes. These sections were replaced by new drainage tunnels, with the lengths of 288.0 meters from west portal and 538.0 meters from eastern portal, to ensure access from both portals. The new drainage tunnel is excavated under the level of the two main tunnel tubes. Drainage pipes with a diameter of 250 mm will be installed from cleaning niches in the main tunnel tubes to the new drainage tunnel.

  20. Hydrogen production from algal biomass - Advances, challenges and prospects.

    PubMed

    Show, Kuan-Yeow; Yan, Yuegen; Ling, Ming; Ye, Guoxiang; Li, Ting; Lee, Duu-Jong

    2018-06-01

    Extensive effort is being made to explore renewable energy in replacing fossil fuels. Biohydrogen is a promising future fuel because of its clean and high energy content. A challenging issue in establishing hydrogen economy is sustainability. Biohydrogen has the potential for renewable biofuel, and could replace current hydrogen production through fossil fuel thermo-chemical processes. A promising source of biohydrogen is conversion from algal biomass, which is abundant, clean and renewable. Unlike other well-developed biofuels such as bioethanol and biodiesel, production of hydrogen from algal biomass is still in the early stage of development. There are a variety of technologies for algal hydrogen production, and some laboratory- and pilot-scale systems have demonstrated a good potential for full-scale implementation. This work presents an elucidation on development in biohydrogen encompassing biological pathways, bioreactor designs and operation and techno-economic evaluation. Challenges and prospects of biohydrogen production are also outlined. Copyright © 2018 Elsevier Ltd. All rights reserved.

  1. STS-30 clean-suited crewmembers examine locker contents during bench review

    NASA Image and Video Library

    1989-04-03

    S89-30260 (31 March 1989) --- The five astronaut crewmembers for NASA's STS-30 mission conduct a bench review of the actual supplies they will be depending on for use aboard the Atlantis when they spend four days in space later in the spring. Left to right are Astronauts Mark C. Lee, mission specialist; Norman E. Thagard, mission specialist; David M. Walker, mission commander; and Mary L. Cleave, mission specialist. Ronald J. Grabe, pilot, is at far right.

  2. Pilot-scale ISCO treatment of a MtBE contaminated site using a Fenton-like process.

    PubMed

    Innocenti, Ivan; Verginelli, Iason; Massetti, Felicia; Piscitelli, Daniela; Gavasci, Renato; Baciocchi, Renato

    2014-07-01

    This paper reports about a pilot-scale feasibility study of In-Situ Chemical Oxidation (ISCO) application based on the use of stabilized hydrogen peroxide catalyzed by naturally occurring iron minerals (Fenton-like process) to a site formerly used for fuel storage and contaminated by MtBE. The stratigraphy of the site consists of a 2-3 meter backfill layer followed by a 3-4 meter low permeability layer, that confines the main aquifer, affected by a widespread MtBE groundwater contamination with concentrations up to 4000 μg/L, also with the presence of petroleum hydrocarbons. The design of the pilot-scale treatment was based on the integration of the results obtained from experimental and numerical modeling accounting for the technological and regulatory constraints existing in the site to be remediated. In particular, lab-scale batch tests allowed the selection of the most suitable operating conditions. Then, this information was implemented in a numerical software that allowed to define the injection and monitoring layout and to predict the propagation of hydrogen peroxide in groundwater. The pilot-scale field results confirmed the effective propagation of hydrogen peroxide in nearly all the target area (around 75 m(2) using 3 injection wells). As far as the MtBE removal is concerned, the ISCO application allowed us to meet the clean-up goals in an area of 60 m(2). Besides, the concentration of TBA, i.e. a potential by-product of MtBE oxidation, was actually reduced after the ISCO treatment. The results of the pilot-scale test suggest that ISCO may be a suitable option for the remediation of the groundwater plume contaminated by MtBE, providing the background data for the design and cost-estimate of the full-scale treatment. Copyright © 2014 Elsevier B.V. All rights reserved.

  3. Cortisol levels in hair of East Greenland polar bears

    PubMed Central

    Bechshøft, TØ; Sonne, C; Dietz, R; Born, EW; Novak, MA; Henchey, E; Meyer, JS

    2010-01-01

    To demonstrate the ability to assess long-term hypothalamic-pituitary-adrenocortical (HPA) axis activity in polar bears (Ursus maritimus), a pilot study was conducted in which cortisol concentrations was analyzed in hair from 7 female (3–19 years) and 10 male (6-19 years) East Greenland polar bears sampled 1994–2006. Hair was chosen as matrix as it is non-invasive, seasonally harmonized, and has been validated as an index of long-term changes in cortisol levels. Samples were categorized according to contamination: Eight were clean (2 females, 6 males), 5 had been contaminated with bear blood (2 F, 3 M), and 4 with bear fat (3 F, 1 M). There was no significant difference in cortisol concentration between the three categories after external contamination was removed. However, contaminated hair samples should be cleaned before cortisol determination. Average hair cortisol concentration was 8.90 pg/mg (range: 5.5 to 16.4 pg/mg). There was no significant correlation between cortisol concentration and age (p = 0.81) or sampling year (p = 0.11). However, females had higher mean cortisol concentration than males (females mean: 11.0 pg/mg, males: 7.3 pg/mg; p = 0.01). The study showed that polar bear hair contains measurable amounts of cortisol and that cortisol in hair may be used in studies of long-term stress in polar bears. PMID:21144554

  4. Cortisol levels in hair of East Greenland polar bears.

    PubMed

    Bechshøft, T Ø; Sonne, C; Dietz, R; Born, E W; Novak, M A; Henchey, E; Meyer, J S

    2011-01-15

    To demonstrate the ability to assess long-term hypothalamic-pituitary-adrenocortical (HPA) axis activity in polar bears (Ursus maritimus), a pilot study was conducted in which cortisol concentrations was analyzed in hair from 7 female (3-19 years) and 10 male (6-19 years) East Greenland polar bears sampled in 1994-2006. The hair was chosen as matrix as it is non-invasive, seasonally harmonized, and has been validated as an index of long-term changes in cortisol levels. The samples were categorized according to contamination: eight were clean (2 females, 6 males), 5 had been contaminated with bear blood (2 F, 3 M), and 4 with bear fat (3 F, 1 M). There was no significant difference in cortisol concentration between the three categories after external contamination was removed. However, contaminated hair samples should be cleaned before cortisol determination. Average hair cortisol concentration was 8.90 pg/mg (range: 5.5 to 16.4 pg/mg). There was no significant correlation between cortisol concentration and age (p=0.81) or sampling year (p=0.11). However, females had higher mean cortisol concentration than males (females mean: 11.0 pg/mg, males: 7.3 pg/mg; p=0.01). The study showed that polar bear hair contains measurable amounts of cortisol and that cortisol in hair may be used in studies of long-term stress in polar bears. Copyright © 2010 Elsevier B.V. All rights reserved.

  5. Design and analysis of a pilot scale biofiltration system for odorous air

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Classen, J.J.; Young, J.S.; Bottcher, R.W.

    2000-02-01

    Three pilot-scale biofilters and necessary peripheral equipment were built to clean odorous air from the pit of a swine gestation building at North Carolina State University. A computer measured temperatures, flow rates, and pressure drops. It also controlled and measured the moisture content of a biofilter medium comprised of a 3:1 mixture of yard waste compost to wood chips mixture (by volume). The system was evaluated to ensure that the biofilters would be useful for performing scientific experiments concerning the reduction of swine odor on future research projects. The capability of the biofilters to remove odor was measured using amore » cotton swatch absorption method and an odor panel. The average odor reductions measured by odor intensity, irritation intensity, and unpleasantness for five tests were 61%, 58%, and 84%, respectively. No significant differences in odor reduction performance were found between the biofilters.« less

  6. Oxygen transfer in a full-depth biological aerated filter.

    PubMed

    Stenstrom, Michael K; Rosso, Diego; Melcer, Henryk; Appleton, Ron; Occiano, Victor; Langworthy, Alan; Wong, Pete

    2008-07-01

    The City of San Diego, California, evaluated the performance capabilities of biological aerated filters (BAFs) at the Point Loma Wastewater Treatment Plant. The City conducted a 1-year pilot-plant evaluation of BAF technology supplied by two BAF manufacturers. This paper reports on the first independent oxygen-transfer test of BAFs at full depth using the offgas method. The tests showed process-water oxygen-transfer efficiencies of 1.6 to 5.8%/m (0.5 to 1.8%/ft) and 3.9 to 7.9%/m (1.2 to 2.4%/ft) for the two different pilot plants, at their nominal design conditions. Mass balances using chemical oxygen demand and dissolved organic carbon corroborated the transfer rates. Rates are higher than expected from fine-pore diffusers for similar process conditions and depths and clean-water conditions for the same column and are mostly attributed to extended bubble retention time resulting from interactions with the media and biofilm.

  7. Pilot trial on separation conditions for diaper recycling.

    PubMed

    Kim, Kyung-Shin; Cho, Hee-Sun

    2017-09-01

    By utilizing laboratory-scale tests, the optimal separation conditions for diaper recycling were identified, and then, these conditions were validated by a pilot trial. In this research, we determined the mass balances derived during various processing steps and identified the most feasible procedures to use for separating each material in the output flow. The results showed that drum screening was not able to remove all the fiber and super absorbent particles (SAP) in the plastic-rich fraction and that cellulose enzyme treatment can be a good solution. To achieve better separation of fibers and SAP, slot screening followed by a cleaner is a potential option. A feasible diaper recycling process was recommended based on these results. This process involves screening and enzymatic treatment for the plastic fraction, and screening, cleaning, and thickening for the fiber fraction. Treatment procedures were also proposed for the SAP fraction and rejected materials. Copyright © 2017. Published by Elsevier Ltd.

  8. [Pilot study on the treatment of ultrafiltration for laundry wastewater recycling and reuse].

    PubMed

    Wang, Jin; Jiang, Jin-Hui

    2007-02-01

    A pilot study of the treatment for laundry wastewater recycling and reuse on the spot was carried out by ultrafiltration (UF) with different membrane material of PAN, PS and PP. According to the analysis of membrane fouling combined with UF effluent quality, PAN membrane was superior to the others. It removed the turbidity, suspended solid, fat oil and grease effectively, but kept anionic surfactant (LAS) to a certain degree in the UF effluent which is beneficial to recycling and reuse. By correlation analysis, it was found the high COD concentration of effluent was caused by LAS remained. The whiteness and softness of cotton cloth washed by UF effluent for a long-term was not different with that washed by tap water. The removal of bacteria and E. coli by UF membrane was not very high, and so UF effluent was disinfected by ultraviolet (UV) further. As the dosage of UV was not less than 3 750 J/m2, the microbial level reached the China national standard of drinking water. The optimal UF operation condition is to backwash two minutes every thirty minutes' filtration. Adopted alkali liquor of pH 11 to 13 to carry out chemical cleaning, the membrane flux was recovered completely.

  9. Reclamation of grey water for non-potable purposes using pilot-scale solar photocatalytic tubular reactors.

    PubMed

    Saran, Sarangapany; Arunkumar, Patchaiyappan; Manjari, Gangarapu; Devipriya, Suja P

    2018-05-05

    Application of pilot-scale slurry-type tubular photocatalytic reactor was tested for the decentralized treatment of actual grey water. The reactors were fabricated by reusing the locally available materials at low cost, operated in batch recycle mode with 25 L of grey water. The influence of operational parameters such as catalysts' concentration, initial slurry pH and addition of H 2 O 2 on COD abatement were optimized. The results show that Ag-decorated TiO 2 showed a two-fold increase in COD abatement than did pure TiO 2 . Better COD abatement was observed under acidic conditions, and addition of H 2 O 2 significantly increases the rate of COD abatement. Within 2 h, 99% COD abatement was observed when the reactor was operated with optimum operational conditions. Silver ion lixiviate was also monitored during the experiment and is five times less than the permissible limits. The catalyst shows good stability even after five cycles without much loss in its photocatalytic activity. The results clearly reveal that pilot-scale slurry tubular solar photocatalytic reactors could be used as a cost-effective method to treat grey water and the resulting clean water could be reused for various non-potable purposes, thus conserving precious water resource. This study favours decentralized grey water treatment and possible scaling up of solar photocatalytic reactor using locally available materials for the potential reuse of treated water.

  10. Biofilm formation and antimicrobial sensitivity of lactobacilli contaminants from sugarcane-based fuel ethanol fermentation.

    PubMed

    Dellias, Marina de Toledo Ferraz; Borges, Clóvis Daniel; Lopes, Mário Lúcio; da Cruz, Sandra Helena; de Amorim, Henrique Vianna; Tsai, Siu Mui

    2018-02-24

    Industrial ethanol fermentation is subject to bacterial contamination that causes significant economic losses in ethanol fuel plants. Chronic contamination has been associated with biofilms that are normally more resistant to antimicrobials and cleaning efforts than planktonic cells. In this study, contaminant species of Lactobacillus isolated from biofilms (source of sessile cells) and wine (source of planktonic cells) from industrial and pilot-scale fermentations were compared regarding their ability to form biofilms and their sensitivity to different antimicrobials. Fifty lactobacilli were isolated and the most abundant species were Lactobacillus casei, Lactobacillus fermentum and Lactobacillus plantarum. The majority of the isolates (87.8%) were able to produce biofilms in pure culture. The capability to form biofilms and sensitivity to virginiamycin, monensin and beta-acids from hops, showed inter- and intra-specific variability. In the pilot-scale fermentation, Lactobacillus brevis, L. casei and the majority of L. plantarum isolates were less sensitive to beta-acids than their counterparts from wine; L. brevis isolates from biofilms were also less sensitive to monensin when compared to the wine isolates. Biofilm formation and sensitivity to beta-acids showed a positive and negative correlation for L. casei and L. plantarum, respectively.

  11. Rectifying calibration error of Goldmann applanation tonometer is easy!

    PubMed

    Choudhari, Nikhil S; Moorthy, Krishna P; Tungikar, Vinod B; Kumar, Mohan; George, Ronnie; Rao, Harsha L; Senthil, Sirisha; Vijaya, Lingam; Garudadri, Chandra Sekhar

    2014-11-01

    Purpose: Goldmann applanation tonometer (GAT) is the current Gold standard tonometer. However, its calibration error is common and can go unnoticed in clinics. Its company repair has limitations. The purpose of this report is to describe a self-taught technique of rectifying calibration error of GAT. Materials and Methods: Twenty-nine slit-lamp-mounted Haag-Streit Goldmann tonometers (Model AT 900 C/M; Haag-Streit, Switzerland) were included in this cross-sectional interventional pilot study. The technique of rectification of calibration error of the tonometer involved cleaning and lubrication of the instrument followed by alignment of weights when lubrication alone didn't suffice. We followed the South East Asia Glaucoma Interest Group's definition of calibration error tolerance (acceptable GAT calibration error within ±2, ±3 and ±4 mm Hg at the 0, 20 and 60-mm Hg testing levels, respectively). Results: Twelve out of 29 (41.3%) GATs were out of calibration. The range of positive and negative calibration error at the clinically most important 20-mm Hg testing level was 0.5 to 20 mm Hg and -0.5 to -18 mm Hg, respectively. Cleaning and lubrication alone sufficed to rectify calibration error of 11 (91.6%) faulty instruments. Only one (8.3%) faulty GAT required alignment of the counter-weight. Conclusions: Rectification of calibration error of GAT is possible in-house. Cleaning and lubrication of GAT can be carried out even by eye care professionals and may suffice to rectify calibration error in the majority of faulty instruments. Such an exercise may drastically reduce the downtime of the Gold standard tonometer.

  12. New process for alleviation of membrane fouling of modified hybrid MBR system for advanced domestic wastewater treatment.

    PubMed

    Shuo, Liu; Baozhen, Wang; Hongjun, Han; Yanping, Liu

    2008-01-01

    A pilot-scale hybrid membrane bioreactor using a submerged flat panel membrane was designed and applied for advanced treatment of domestic wastewater. The new process adapted to the hybrid membrane bioreactor exhibits substantial decrease in membrane fouling and much easier cleaning. In this study, the new process configurations including the addition of anoxic/anaerobic zones, the package of synthetic fibrous fabric carrier for biofilm attached growth, activated sludge recycling and modified dosage of polished diatomite with high activity and multi-functions were investigated to select the optimal operational parameters for the hybrid membrane bioreactor system. The carrier package in the aerobic zone contributed 3.65 g/L (maximum) of fixed biomass to the system, thus reducing the suspended biomass, and has decreased the membrane cleaning cycle remarkably. The operation performance at the sludge recycle rate 0, 100%, 200% and 300% showed that, the trans-membrane pressure of flat panel membrane declined sharply with the increase of sludge recycling rate within a certain range, and 200% was decided to be optimal for in the membrane bioreactor system. EPS concentration in each sludge recycling rate was 135 mg/L, 92 mg/L, 68 mg/L and 55 mg/L respectively. The addition of anoxic and anaerobic zones degraded some large molecular organic compounds, which facilitated the biodegradation and removal of organic substances in aerobic zone. The modified dosage of polished diatomite has played a major important role for both preventing of membrane from fouling and its much easier cleaning when it formed. Copyright (c) IWA Publishing 2008.

  13. Duodenoscope reprocessing surveillance with adenosine triphosphate testing and terminal cultures: a clinical pilot study.

    PubMed

    Visrodia, Kavel; Hanada, Yuri; Pennington, Kelly M; Tosh, Pritish K; Topazian, Mark D; Petersen, Bret T

    2017-07-01

    Recent reports of infectious outbreaks linked to duodenoscopes have led to proposals for duodenoscope surveillance culturing, which has inherent limitations. We aimed to assess the feasibility of real-time adenosine triphosphate (ATP) testing after manual cleaning and its ability to predict reprocessing adequacy, as determined by terminal duodenoscope cultures. Clinically used duodenoscopes underwent reprocessing per current guidelines. After manual cleaning, ATP samples were obtained from the elevator, within the proximal biopsy port, and by flushing of the biopsy channel. After high-level disinfection (HLD), aerobic cultures of the elevator and biopsy channel were obtained using sterile technique. Duodenoscopes with any ATP sample ≥200 relative light units underwent repeated cycles of cleaning, ATP testing, HLD, and terminal culturing. Twenty clinically used duodenoscopes were included; 18 underwent a second reprocessing cycle, and 6 underwent a third reprocessing cycle because of detection of high ATP. After the initial reprocessing cycle, 12 of 20 (60%) duodenoscopes had positive culture results, most commonly yielding gram-negative bacilli (GNB, n = 11 from 9 duodenoscopes), and catalase-positive gram-positive cocci (CP-GPC, n = 7 from 7 duodenoscopes), suggesting staphylococcal organisms. Ambient environmental controls also showed GNB and CP-GPC growth. The overall sensitivity and specificity of ATP testing compared with terminal cultures were 30% and 53%, respectively. ATP sampling appears to correlate poorly with terminal culture results and cannot be recommended as a surrogate for terminal cultures. The performance and interpretation of cultures remains complicated by the potential recovery of environmental contaminants. Copyright © 2017 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.

  14. Space Solar Power Concepts: Demonstrations to Pilot Plants

    NASA Technical Reports Server (NTRS)

    Carrington, Connie K.; Feingold, Harvey; Howell, Joe T. (Technical Monitor)

    2002-01-01

    The availability of abundant, affordable power where needed is a key to the future exploration and development of space as well as future sources of clean terrestrial power. One innovative approach to providing such power is the use of wireless power transmission (WPT). There are at least two possible WPT methods that appear feasible; microwave and laser. Microwave concepts have been generated, analyzed and demonstrated. Technologies required to provide an end-to-end system have been identified and roadmaps generated to guide technology development requirements. Recently, laser W T approaches have gained an increased interest. These approaches appear to be very promising and will possibly solve some of the major challenges that exist with the microwave option. Therefore, emphasis is currently being placed on the laser WPT activity. This paper will discuss the technology requirements, technology roadmaps and technology flight experiments demonstrations required to lead toward a pilot plant demonstration. Concepts will be discussed along with the modeling techniques that are used in developing them. Feasibility will be addressed along with the technology needs, issues and capabilities for particular concepts. Flight experiments and demonstrations will be identified that will pave the road from demonstrations to pilot plants and beyond.

  15. A specific pilot-scale membrane hybrid treatment system for municipal wastewater treatment.

    PubMed

    Nguyen, Dinh Duc; Ngo, Huu Hao; Kim, Sa Dong; Yoon, Yong Soo

    2014-10-01

    A specifically designed pilot-scale hybrid wastewater treatment system integrating an innovative equalizing reactor (EQ), rotating hanging media bioreactor (RHMBR) and submerged flat sheet membrane bioreactor (SMBR) was evaluated for its effectiveness in practical, long-term, real-world applications. The pilot system was operated at a constant flux, but with different internal recycle flow rates (Q) over a long-term operating of 475 days. At 4 Q internal recycle flow rate, BOD5, CODCr, NH4(+)-N, T-N, T-P and TSS was highly removed with efficiencies up to 99.88 ± 0.05%, 95.01 ± 1.62%, 100%, 90.42 ± 2.43%, 73.44 ± 6.03%, and 99.93 ± 0.28%, respectively. Furthermore, the effluent quality was also superior in terms of turbidity (<1 NTU), color (<15 TCU) and taste (inoffensive). The results indicated that with providing only chemically cleaned-in-place (CIP) during the entire period of operation, the membrane could continuously maintain a constant permeate flux of 22.77 ± 2.19 L/m(2)h. In addition, the power consumption was also found to be reasonably low (0.92-1.62 k Wh/m(3)). Copyright © 2014 Elsevier Ltd. All rights reserved.

  16. Development of a nanofiltration method for bone collagen 14C AMS dating

    NASA Astrophysics Data System (ADS)

    Boudin, Mathieu; Boeckx, Pascal; Buekenhoudt, Anita; Vandenabeele, Peter; Van Strydonck, Mark

    2013-01-01

    Radiocarbon dating of bones is usually performed on the collagen fraction. However, this collagen can contain exogenous molecules, including humic substances (HSs) and/or other soil components that may have a different age than the bone. Incomplete removal can result in biased 14C dates. Ultrafiltration of collagen, dissolved as gelatin (molecular weight (MW) ∼100,000 Dalton), has received considerable attention to obtain more reliable dates. Ultrafiltration is an effective method of removal of low-molecular weight contaminants from bone collagen but it does not remove high-molecular weight contaminants, such as cross-linked humic collagen complexes. However, comparative dating studies have raised the question whether this cleaning step itself may introduce contamination with carbon from the filters used. In this study, a nanofiltration method was developed using a ceramic filter to avoid a possible extraneous carbon contamination introduced by the filter. This method should be applicable to various protein materials e.g. collagen, silk, wool, leather and should be able to remove low-molecular and high molecular weight HSs. In this study bone collagen was hot acid hydrolyzed to amino acids and nanofiltrated. A filter with a molecular weight cutoff (MWCO) of 450 Dalton was chosen in order to collect the amino acids in the permeate and the HSs in the retentate. Two pilot studies were set up. Two nanofiltration types were tested in pilot study 1: dead end and cross flow filtration. Humic substance (HS)-solutions with fossil carbon and modern hydrolyzed collagen contaminated with HSs were filtrated and analyzed with spectrofluorescence to determine the HS removal. Cross flow nanofiltration showed the most efficient HS removal. A second pilot study based upon these results was set up wherein only cross flow filtration was performed. 14C measurements of the permeates of hydrolyzed modern collagen contaminated with fossil HSs demonstrate a significant but incomplete removal of HSs (between 63% and 85%).

  17. Assessment of performing an MST strike in Tank 21H

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Poirier, Michael R.

    2014-09-29

    Previous Savannah River National Laboratory (SRNL) tank mixing studies performed for the Small Column Ion Exchange (SCIX) project have shown that 3 Submersible Mixer Pumps (SMPs) installed in Tank 41 are sufficient to support actinide removal by MST sorption as well as subsequent resuspension and removal of settled solids. Savannah River Remediation (SRR) is pursuing MST addition into Tank 21 as part of the Large Tank Strike (LTS) project. The preliminary scope for LTS involves the use of three standard slurry pumps (installed in N, SE, and SW risers) in a Type IV tank. Due to the differences in tankmore » size, internal interferences, and pump design, a separate mixing evaluation is required to determine if the proposed configuration will allow for MST suspension and strontium and actinide sorption. The author performed the analysis by reviewing drawings for Tank 21 [W231023] and determining the required cleaning radius or zone of influence for the pumps. This requirement was compared with previous pilot-scale MST suspension data collected for SCIX that determined the cleaning radius, or zone of influence, as a function of pump operating parameters. The author also reviewed a previous Tank 50 mixing analysis that examined the ability of standard slurry pumps to suspend sludge particles. Based on a review of the pilot-scale SCIX mixing tests and Tank 50 pump operating experience, three standard slurry pumps should be able to suspend sludge and MST to effectively sorb strontium and actinides onto the MST. Using the SCIX data requires an assumption about the impact of cooling coils on slurry pump mixing. The basis for this assumption is described in this report. Using the Tank 50 operating experience shows three standard slurry pumps should be able to suspend solids if the shear strength of the settled solids is less than 160 Pa. Because Tank 21 does not contain cooling coils, the shear strength could be larger.« less

  18. Caregiver perspectives in oral healthcare in an institutionalised elderly population without access to dental services: a pilot study.

    PubMed

    Matear, David; Barbaro, John

    2006-01-01

    The provision of dental services to elderly populations is a complicated area. When clients are cognitively impaired, a new set of variables are introduced as care can be influenced by designated family members, caregivers or administrators, who are responsible for the oral health care of the client and may influence the types of treatment the client will receive. Differences in attitudes and perceptions, with respect to oral health, may lead to better or worse access to care. The goals of this study are: (a) to gain a better understanding of the perceptions which may govern access and barriers to care within the institutionalised elderly population; and (b) to improve information on where and how to target educational and service resources, in order to reduce barriers to care. A convenience (non-randomised) sample of 100 residents with caregivers was selected from nursing homes without organised access to oral healthcare services. A structured interview was conducted with 40 family members. Questions explored the importance and priorities of dental services for elderly people in institutions. Services which family members deemed of highest importance were dentures (both to replace teeth and adjustments on existing dentures), pain relief, emergency dentistry, fillings, cleanings, check-ups, tooth removal and treatment for advanced gum disease. Services that family members felt were less important were complex restorations, cleaning instruction to caregivers and seniors, and services by a specialist. Services considered to be of least importance were root canal treatment and implants. The top service priorities identified by the sample of family members included: cleanings to prevent mouth disease; check-ups including X-rays; fillings; dentures to replace teeth; and dental treatment to relieve pain. This study found that family members and caregivers would like a basic dental service including check-ups and preventive care, with restorative, denture and surgical intervention when required.

  19. Emission Reduction of Fuel-Staged Aircraft Engine Combustor Using an Additional Premixed Fuel Nozzle.

    PubMed

    Yamamoto, Takeshi; Shimodaira, Kazuo; Yoshida, Seiji; Kurosawa, Yoji

    2013-03-01

    The Japan Aerospace Exploration Agency (JAXA) is conducting research and development on aircraft engine technologies to reduce environmental impact for the Technology Development Project for Clean Engines (TechCLEAN). As a part of the project, combustion technologies have been developed with an aggressive target that is an 80% reduction over the NO x threshold of the International Civil Aviation Organization (ICAO) Committee on Aviation Environmental Protection (CAEP)/4 standard. A staged fuel nozzle with a pilot mixer and a main mixer was developed and tested using a single-sector combustor under the target engine's landing and takeoff (LTO) cycle conditions with a rated output of 40 kN and an overall pressure ratio of 25.8. The test results showed a 77% reduction over the CAEP/4 NO x standard. However, the reduction in smoke at thrust conditions higher than the 30% MTO condition and of CO emission at thrust conditions lower than the 85% MTO condition are necessary. In the present study, an additional fuel burner was designed and tested with the staged fuel nozzle in a single-sector combustor to control emissions. The test results show that the combustor enables an 82% reduction in NO x emissions relative to the ICAO CAEP/4 standard and a drastic reduction in smoke and CO emissions.

  20. Stethoscope disinfection campaign in a Nigerian teaching hospital:results of a before-and-after study.

    PubMed

    Uneke, Chigozie J; Ndukwe, Chinwendu D; Nwakpu, Kingsley O; Nnabu, Richard C; Ugwuoru, Cletus D; Prasopa-Plaizier, Nittita

    2014-01-15

    This study aimed to assess the impact of a stethoscope disinfection sensitization campaign among doctors and nurses in a Nigerian teaching hospital. The design was a before-and-after study. Pre-program measurements were used to provide a baseline against which the post-program results were compared. Interventions that promoted compliance with stethoscope disinfection practice that were implemented included training and education on stethoscope disinfection and introduction of 70% isopropyl alcohol disinfectant at points-of-care places. Microbiological assessment of stethoscopes used by health workers was conducted after the intervention and the outcome was compared with the pilot study results. After the intervention, of the 89 stethoscopes screened, 18 (20.2%) were contaminated with bacterial agents. A higher prevalence of stethoscope contamination was observed among stethoscopes from the intensive care unit (66.7%), the VIP unit (50%), and the antenatal unit (37.5%). The main isolates were Staphylococcus aureus (44.4%) and Escherichia coli (50%). The antibiotic sensitivity assessment indicated that the bacterial isolates were resistant to nearly all the antibiotics tested. All the 89 health workers whose stethoscopes were screened after the intervention admitted to cleaning their stethoscopes after seeing each patient, representing a compliance rate of 100%, unlike the 15% compliance at the pilot phase. The baseline stethoscope contamination rate was 78.5% versus 20.2% post-intervention. Training and education and introduction of alcohol-based disinfectants inexpensive but very effective methods to improve stethoscope disinfection compliance among health workers in low-income settings.

  1. Benchmark Study of Global Clean Energy Manufacturing | Advanced

    Science.gov Websites

    Manufacturing Research | NREL Benchmark Study of Global Clean Energy Manufacturing Benchmark Study of Global Clean Energy Manufacturing Through a first-of-its-kind benchmark study, the Clean Energy Technology End Product.' The study examined four clean energy technologies: wind turbine components

  2. Electrostatic precipitation is a novel way of maintaining visual field clarity during laparoscopic surgery: a prospective double-blind randomized controlled pilot study.

    PubMed

    Ansell, James; Warren, Neil; Wall, Pete; Cocks, Kim; Goddard, Stuart; Whiston, Richard; Stechman, Michael; Scott-Coombes, David; Torkington, Jared

    2014-07-01

    Ultravision™ is a new device that utilizes electrostatic precipitation to clear surgical smoke. The aim was to evaluate its performance during laparoscopic cholecystectomy. Patients undergoing laparoscopic cholecystectomy were randomized into "active (device on)" or "control (device off)." Three operating surgeons scored the percentage effective visibility and three reviewers scored the percentage of the procedure where smoke was present. All assessors also used a 5-point scale (1 = imperceptible/excellent and 5 = very annoying/bad) to rate visual impairment. Secondary outcomes were the number of smoke-related pauses, camera cleaning, and pneumoperitoneum reductions. Mean results are presented with 95% confidence intervals (CI). In 30 patients (active 13, control 17), the effective visibility was 89.2% (83.3-95.0) for active cases and 71.2% (65.7-76.7) for controls. The proportion of the procedure where smoke was present was 41.1% (33.8-48.3) for active cases and 61.5% (49.0-74.1) for controls. Operating surgeons rated the visual impairment as 2.2 (1.7-2.6) for active cases and 3.2 (2.8-3.5) for controls. Reviewers rated the visual impairment as 2.3 (2.0-2.5) for active cases and 3.2 (2.8-3.7) for controls. In the active group, 23% of procedures were paused to allow smoke clearance compared to 94% of control cases. Camera cleaning was not needed in 85% of active procedures and 35% of controls. The pneumoperitoneum was reduced in 0% of active cases and 88% of controls. Ultravision™ improves visibility during laparoscopic surgery and reduces delays in surgery for smoke clearance and camera cleaning.

  3. Development and application of a Chinese webpage suicide information mining system (sims).

    PubMed

    Chen, Penglai; Chai, Jing; Zhang, Lu; Wang, Debin

    2014-11-01

    This study aims at designing and piloting a convenient Chinese webpage suicide information mining system (SIMS) to help search and filter required data from the internet and discover potential features and trends of suicide. SIMS utilizes Microsoft Visual Studio2008, SQL2008 and C# as development tools. It collects webpage data via popular search engines; cleans the data using trained models plus minimum manual help; translates the cleaned texts into quantitative data through models and supervised fuzzy recognition; analyzes and visualizes related variables by self-programmed algorithms. The SIMS developed comprises such functions as suicide news and blogs collection, data filtering, cleaning, extraction and translation, data analysis and presentation. SIMS-mediated mining of one-year webpage revealed that: peak months and hours of web-reported suicide events were June-July and 10-11 am respectively, and the lowest months and hours, September-October and 1-7 am; suicide reports came mostly from Soho, Tecent, Sina etc.; male suicide victims over counted female victims in most sub-regions but southwest China; homes, public places and rented houses were the top three places to commit suicide; poisoning, cutting vein and jumping from building were the most commonly used methods to commit suicide; love disputes, family disputes and mental diseases were the leading causes. SIMS provides a preliminary and supplementary means for monitoring and understanding suicide. It proposes useful aspects as well as tools for analyzing the features and trends of suicide using data derived from Chinese webpages. Yet given the intrinsic "dual nature" of internet-based suicide information and the tremendous difficulties experienced by ourselves and other researchers, there is still a long way to go for us to expand, refine and evaluate the system.

  4. An application of the theory of planned behavior--a randomized controlled food safety pilot intervention for young adults.

    PubMed

    Milton, Alyssa C; Mullan, Barbara A

    2012-03-01

    Approximately 48 million Americans are affected by foodborne illness each year. Evidence suggests that the application of health psychology theory to food safety interventions can increase behaviors that reduce the incidence of illness such as adequately keeping hands, surfaces and equipment clean. This aim of this pilot study was to be the first to explore the effectiveness of a food safety intervention based on the Theory of Planned Behavior (TPB). Young adult participants (N = 45) were randomly allocated to intervention, general control or mere measurement control conditions. Food safety observations and TPB measures were taken at baseline and at 4-week follow-up. Within and between group differences on target variables were considered and regression analyses were conducted to determine the relationship between condition, behavior and the TPB intention constructs; attitude, subjective norm, perceived behavioral control (PBC). TPB variables at baseline predicted observed food safety behaviors. At follow-up, the intervention led to significant increases in PBC (p = .024) and observed behaviors (p = .001) compared to both control conditions. Furthermore, correlations were found between observed and self-reported behaviors (p = .008). The pilot intervention supports the utility of the TPB as a method of improving food safety behavior. Changes in TPB cognitions appear to be best translated to behavior via behavioral intentions and PBC. Further research should be conducted to increase effectiveness of translating TPB variables to food safety behaviors. The additional finding of a correlation between self-reported and observed behavior also has implications for future research as it provides evidence toward the construct validity of self-reported behavioral measures.

  5. Nanofiltration for concentration of roasted coffee extract: From bench to pilot

    NASA Astrophysics Data System (ADS)

    Dat, Lai Quoc; Quyen, Nguyen Thi Ngoc

    2017-09-01

    This paper focused on the application of nanofiltration (NF) for concentration of the roasted coffee extract in instant coffee processing. Three kinds of NF membranes were screened for separation capacity of total dry solid (TDS), polyphenols (PPs) and caffeine in roasted coffee extract and NF99 membrane showed the good performance for the NF of the extract. The crossflow NF with NF99 membrane at pilot scale was investigated for technical assessment of concentration of roasted coffee extract. Maximum theoretical concentration was estimated as 6.06. Recovery yields of TDS, PPs and caffeine were higher than 70% at 4.4 of concentration factor. The content of TDS in accumulative permeate was lower than 2.0 g/L. The fouling of NF was also solved by the suitable cleaning procedure with recovery index being 97.7%. Results of research indicate that it is feasible to apply NF for concentration of the roasted coffee extract in instant coffee production.

  6. Well installation and documentation, and ground-water sampling protocols for the pilot National Water-Quality Assessment Program

    USGS Publications Warehouse

    Hardy, M.A.; Leahy, P.P.; Alley, W.M.

    1989-01-01

    Several pilot projects are being conducted as part of the National Water Quality Assessment (NAWQA) Program. The purpose of the pilot program is to test and refine concepts for a proposed full-scale program. Three of the pilot projects are specifically designed to assess groundwater. The purpose of this report is to describe the criteria that are being used in the NAWQA pilot projects for selecting and documenting wells, installing new wells, and sampling wells for different water quality constituents. Guidelines are presented for the selection of wells for sampling. Information needed to accurately document each well includes site characteristics related to the location of the well, land use near the well, and important well construction features. These guidelines ensure the consistency of the information collected and will provide comparable data for interpretive purposes. Guidelines for the installation of wells are presented and include procedures that need to be followed for preparations prior to drilling, the selection of the drilling technique and casing type, the grouting procedure, and the well-development technique. A major component of the protocols is related to water quality sampling. Tasks are identified that need to be completed prior to visiting the site for sampling. Guidelines are presented for purging the well prior t sampling, both in terms of the volume of water pumped and the chemical stability of field parameters. Guidelines are presented concerning sampler selection as related to both inorganic and organic constituents. Documentation needed to describe the measurements and observations related to sampling each well and treating and preserving the samples are also presented. Procedures are presented for the storage and shipping of water samples, equipment cleaning, and quality assurance. Quality assurance guidelines include the description of the general distribution of the various quality assurance samples (blanks, spikes, duplicates, and reference samples) that will be used in the pilot program. (Lantz-PTT)

  7. Evaluation of pilot-scale pulse-corona-induced plasma device to remove NO{sub x} from combustion exhausts from a subscale combustor and from a hush house at Nellis AFB, Nevada. Final report, August 1994--January 1997

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Haythornthwaite, S.M.; Durham, M.D.; Anderson, G.L.

    1997-05-01

    Jet engine test cells (JETCs) are used to test-fire new, installed, and reworked jet engines. Because JETCs have been classified as stationary sources of pollutant emissions, they are subject to possible regulation under Title 1 of the Clean Air Act (CAA) as amended in 1990. In Phase 1 of the Small Business Innovation Research (SBIR) program, a novel NOx-control approach utilizing pulsed-corona-induced plasma successfully showed 90% removal of NOx in the laboratory. The objective of Phase 2 was to reproduce the laboratory-scale results in a pilot-scale system. The technology was successfully demonstrated at pilot scale in the field, on amore » slipstream of JETC flue gas at Nellis Air Force Base. Based on the field data, cost projections were made for a system to treat the full JETC exhaust. The technology efficiently converted NO into ONO, and a wet scrubber was required to achieve the treatment goal of 50-percent removal and destruction of NOx. The plasma simultaneously removes hydrocarbons from the flue gas stream. This project demonstrated that pulse-corona-induced plasma technology is scalable to practical industrial dimensions.« less

  8. Precoagulation-microfiltration for wastewater reuse.

    PubMed

    Hatt, J W; Germain, E; Judd, S J

    2011-12-01

    A range of coagulant chemicals and doses, up to 2 mg/L, were trialled on a microfiltration-based indirect potable reuse (IPR) pilot plant to evaluate their impact on membrane reversible and irreversible fouling. Jar tests revealed these doses to have negligible impact on organic matter removal, whilst scoping pilot trials showed them to have a positive impact on fouling rates. Initial trials carried out over a 6-h period suggested that ferric sulphate was the most promising of the coagulants tested with regards to irreversible fouling. Extended five-day trials using ferric sulphate at 0.5 mg/L were conducted at fluxes of 40-50 l/(m(2)h) (LMH). Operation at 50 LMH without coagulant resulted in rapid fouling and a subsequent shortening of the chemical cleaning interval. The addition of the ferric coagulant resulted in a reduction in both reversible and irreversible fouling to those levels experienced at 40 LMH, enabling sustainable operation. The use of low levels of coagulant thus enables the pilot plant to operate at a 25% increased flux, equating to a 20% reduction in membrane area and overall savings of >0.1 p per m(3) for a seven year membrane life. Copyright © 2011 Elsevier Ltd. All rights reserved.

  9. Exploring surface cleaning strategies in hospital to prevent contact transmission of methicillin-resistant Staphylococcus aureus.

    PubMed

    Lei, Hao; Jones, Rachael M; Li, Yuguo

    2017-01-18

    Cleaning of environmental surfaces in hospitals is important for the control of methicillin-resistant Staphylococcus aureus (MRSA) and other hospital-acquired infections transmitted by the contact route. Guidance regarding the best approaches for cleaning, however, is limited. In this study, a mathematical model based on ordinary differential equations was constructed to study MRSA concentration dynamics on high-touch and low-touch surfaces, and on the hands and noses of two patients (in two hospitals rooms) and a health care worker in a hypothetical hospital environment. Two cleaning interventions - whole room cleaning and wipe cleaning of touched surfaces - were considered. The performance of the cleaning interventions was indicated by a reduction in MRSA on the nose of a susceptible patient, relative to no intervention. Whole room cleaning just before first patient care activities of the day was more effective than whole room cleaning at other times, but even with 100% efficiency, whole room cleaning only reduced the number of MRSA transmitted to the susceptible patient by 54%. Frequent wipe cleaning of touched surfaces was shown to be more effective that whole room cleaning because surfaces are rapidly re-contaminated with MRSA after cleaning. Wipe cleaning high-touch surfaces was more effective than wipe cleaning low-touch surfaces for the same frequency of cleaning. For low wipe cleaning frequency (≤3 times per hour), high-touch surfaces should be targeted, but for high wipe cleaning frequency (>3 times per hour), cleaning should target high- and low-touch surfaces in proportion to the surface touch frequency. This study reproduces the observations from a field study of room cleaning, which provides support for the validity of our findings. Daily whole room cleaning, even with 100% cleaning efficiency, provides limited reduction in the number of MRSA transmitted to susceptible patients via the contact route; and should be supplemented with frequent targeted cleaning of high-touch surfaces, such as by a wipe or cloth containing disinfectant.

  10. A multi-residue method for 17 anticoccidial drugs and ractopamine in animal tissues by liquid chromatography-tandem mass spectrometry and time-of-flight mass spectrometry.

    PubMed

    Matus, Johanna L; Boison, Joe O

    2016-05-01

    A new and sensitive multi-residue liquid chromatography-tandem mass spectrometry (LC-MS/MS) and liquid chromatography-quadrupole time-of-flight-mass spectrometry (LC-QToF-MS) method was developed and validated for the determination and confirmation of residues of 17 anticoccidials, plus free ractopamine in poultry muscle and liver, and bovine muscle, liver, and kidney tissues. The 17 anticoccidials are lasalocid, halofuginone, narasin, monensin, semduramicin, ethopabate, robenidine, buquinolate, toltrazuril as its sulfone metabolite, maduramicin, salinomycin, diclazuril, amprolium, decoquinate, dinitolmide, clopidol, and the nicarbazin metabolite DNC (N,N1-bis(4-nitrophenyl)urea). The analytes were extracted and cleaned up within a 3-hour period by simply extracting the analytes into a solvent mixture with salts followed by centrifugation, dilution, and filtration. The validated method was used in a pilot study for the analysis of 173 samples that included quail liver, bovine kidney, liver, muscle, and horse muscle. The predominant residues found in this study were monensin, ractopamine, and lasalocid. The results of this pilot study showed that this new method is applicable to real samples, and is fit for use in a regulatory testing programme. © 2016 Her Majesty the Queen in Right of Canada. Drug Testing and Analysis. © 2016 John Wiley & Sons, Ltd. © 2016 Her Majesty the Queen in Right of Canada. Drug Testing and Analysis. © 2016 John Wiley & Sons, Ltd.

  11. Evaluation of a Biological Pathogen Decontamination Protocol for Animal Feed Mills.

    PubMed

    Huss, Anne R; Cochrane, Roger A; Deliephan, Aiswariya; Stark, Charles R; Jones, Cassandra K

    2015-09-01

    Animal feed and ingredients are potential vectors of pathogenic bacteria. Contaminated ingredients can contaminate facility equipment, leading to cross-contamination of other products. This experiment was conducted to evaluate a standardized protocol for decontamination of an animal feed manufacturing facility using Enterococcus faecium (ATCC 31282) as an indicator. A pelleted swine diet inoculated with E. faecium was manufactured, and environmental samples (swabs, replicate organism detection and counting plates, and air samples) were collected (i) before inoculation (baseline data), (ii) after production of inoculated feed, (iii) after physical removal of organic material using pressurized air, (iv) after application of a chemical sanitizer containing a quaternary ammonium-glutaraldehyde blend, (v) after application of a chemical sanitizer containing sodium hypochlorite, (vi) after facility heat-up to 60 8 C for 24 h, (vii) for 48 h, and (viii) for 72 h. Air samples collected outside the facility confirmed pathogen containment; E. faecium levels were equal to or lower than baseline levels at each sample location. The decontamination step and its associated interactions were the only variables that affected E. faecium incidence (P < 0.0001 versus P > 0.22). After production of the inoculated diet, 85.7% of environmental samples were positive for E. faecium. Physical cleaning of equipment had no effect on contamination (P = 0.32). Chemical cleaning with a quaternary ammonium-glutaraldehyde blend and sodium hypochlorite each significantly reduced E. faecium contamination (P < 0.0001) to 28.6 and 2.4% of tested surfaces, respectively. All samples were negative for E. faecium after 48 h of heating. Both wet chemical cleaning and facility heating but not physical cleaning resulted in substantial E. faecium decontamination. These results confirmed both successful containment and decontamination of biological pathogens in the tested pilot-scale feed mill.

  12. Effects of different pretreatments on the performance of ceramic ultrafiltration membrane during the treatment of oil sands tailings pond recycle water: a pilot-scale study.

    PubMed

    Loganathan, Kavithaa; Chelme-Ayala, Pamela; El-Din, Mohamed Gamal

    2015-03-15

    Membrane filtration is an effective treatment method for oil sands tailings pond recycle water (RCW); however, membrane fouling and rapid decrease in permeate flux caused by colloids, organic matter, and bitumen residues present in the RCW hinder its successful application. This pilot-scale study investigated the impact of different pretreatment steps on the performance of a ceramic ultrafiltration (CUF) membrane used for the treatment of RCW. Two treatment trains were examined: treatment train 1 consisted of coagulant followed by a CUF system, while treatment train 2 included softening (Multiflo™ system) and coagulant addition, followed by a CUF system. The results indicated that minimum pretreatment (train 1) was required for almost complete solids removal. The addition of a softening step (train 2) provided an additional barrier to membrane fouling by reducing hardness-causing ions to negligible levels. More than 99% removal of turbidity and less than 20% removal of total organic carbon were achieved regardless of the treatment train used. Permeate fluxes normalized at 20 °C of 127-130 L/m(2) h and 111-118 L/m(2) h, with permeate recoveries of 90-93% and 90-94% were observed for the treatment trains 1 and 2, respectively. It was also found that materials deposited onto the membrane surface had an impact on trans-membrane pressure and influenced the required frequencies of chemically enhanced backwashes (CEBs) and clean-in-place (CIP) procedures. The CIP performed was successful in removing fouling and scaling materials such that the CUF performance was restored to baseline levels. The results also demonstrated that due to their low turbidity and silt density index values, permeates produced in this pilot study were suitable for further treatment by high pressure membrane processes. Copyright © 2015 Elsevier Ltd. All rights reserved.

  13. Flying Qualities Evaluation of a Commuter Aircraft With an Ice Contaminated Tailplane

    NASA Technical Reports Server (NTRS)

    Ranaudo, Richard J.; Ratvasky, Thomas P.; FossVanZante, Judith

    2000-01-01

    During the NASA/FAA (Federal Aviation Administration) Tailplane Icing Program, pilot evaluations of aircraft flying qualities were conducted with various ice shapes attached to the horizontal tailplane of the NASA Twin Otter Icing Research Aircraft. Initially, only NASA pilots conducted these evaluations, assessing the differences in longitudinal flight characteristics between the baseline or clean aircraft, and the aircraft configured with an Ice Contaminated Tailplane (ICT). Longitudinal tests included Constant Airspeed Flap Transitions, Constant Airspeed Thrust Transitions, zero-G Pushovers, Repeat Elevator Doublets, and Simulated Approach and Go-Around tasks. Later in the program, guest pilots from government and industry were invited to fly the NASA Twin Otter configured with a single full-span artificial ice shape attached to the leading edge of the horizontal tailplane. This shape represented ice formed due to a 'Failed Boot' condition, and was generated from tests in the Glenn Icing Research Tunnel on a full-scale tailplane model. Guest pilots performed longitudinal handling tests, similar to those conducted by the NASA pilots, to evaluate the ICT condition. In general, all pilots agreed that longitudinal flying qualities were degraded as flaps were lowered, and further degraded at high thrust settings. Repeat elevator doublets demonstrated reduced pitch damping effects due to ICT, which is a characteristic that results in degraded flying qualities. Pilots identified elevator control force reversals (CFR) in zero-G pushovers at a 20 deg flap setting, a characteristic that fails the FAR 25 no CFR certification requirement. However, when the same pilots used the Cooper-Harper rating scale to perform a simulated approach and go-around task at the 20 deg flap setting, they rated the airplane as having Level I and Level II flying qualities respectively. By comparison, the same task conducted at the 30 deg flap setting, resulted in Level II flying qualities for the approach portion, and Level III for the go-around portion.The results of this program indicate that safe and acceptable flying qualities with an ICT condition, can be effectively assessed by task-oriented pilot maneuvers. In addition, other maneuvers such as repeat elevator doublets provide good qualitative and quantitative assessments of pitch damping and elevator effectiveness, which are characteristics that correlate well with pilot task ratings. The results of this testing indicate that the FAR 25 zero-G pushover maneuver, which requires no CFR during its execution, may be an overly conservative pass/fail criteria for aircraft certification.

  14. DOE Office of Scientific and Technical Information (OSTI.GOV)

    M., Zimring,; Hoffman, I.; Fuller, M.

    The Federal Housing Finance Agency (FHFA) regulates Fannie Mae, Freddie Mac, and the 12 Federal Home Loan Banks (the government-sponsored enterprises - GSEs). On July 6, 2010, FHFA and the Office of the Comptroller of the Currency (OCC) concluded that Property Assessed Clean Energy (PACE) programs 'present significant safety and soundness concerns' to the housing finance industry. This statement came after a year of discussions with state and federal agencies in which PACE, a novel mechanism for financing energy efficiency and renewable energy improvements, has gone from receiving support from the White House, canonization as one of Scientific American's 'Worldmore » Changing Ideas' and legislative adoption in 24 states to questionable relevance, at least in the residential sector. Whether PACE resumes its expansion as an innovative tool for financing energy efficiency and clean generation depends on outcomes in each of the three branches of government - discussions on a PACE pilot phase among federal agencies, litigation in federal court, and legislation in Congress - all highly uncertain. This policy brief addresses the practical impacts of these possible outcomes on existing and emerging PACE programs across the United States and potential paths forward.« less

  15. A systematic assessment of the state of hazardous waste clean-up technologies. Quarterly technical progress report, April 1--June 30, 1993

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Berg, M.T.; Reed, B.E.; Gabr, M.

    1993-07-01

    West Virginia University (WVU) and the US DOE Morgantown Energy Technology Center (METC) entered into a Cooperative Agreement on August 29, 1992 entitled ``Decontamination Systems Information and Research Programs.`` Stipulated within the Agreement is the requirement that WVU submit to METC a series of Technical Progress Report for Year 1 of the Agreement. This report reflects the progress and/or efforts performed on the following nine technical projects encompassed by the Year 1 Agreement for the period of April 1 through June 30, 1993: Systematic assessment of the state of hazardous waste clean-up technologies; site remediation technologies -- drain-enhanced soil flushingmore » (DESF) for organic contaminants removal; site remediation technologies -- in situ bioremediation of organic contaminants; excavation systems for hazardous waste sites; chemical destruction of polychlorinated biphenyls; development of organic sensors -- monolayer and multilayer self-assembled films for chemical sensors; Winfield lock and dam remediation; Assessments of Technologies for hazardous waste site remediation -- non-treatment technologies and pilot scale test facility implementation; and remediation of hazardous sites with stream reforming.« less

  16. Steel dust in the New York City subway system as a source of manganese, chromium, and iron exposures for transit workers.

    PubMed

    Chillrud, Steven N; Grass, David; Ross, James M; Coulibaly, Drissa; Slavkovich, Vesna; Epstein, David; Sax, Sonja N; Pederson, Dee; Johnson, David; Spengler, John D; Kinney, Patrick L; Simpson, H James; Brandt-Rauf, Paul

    2005-03-01

    The United States Clean Air Act Amendments of 1990 reflected increasing concern about potential effects of low-level airborne metal exposure on a wide array of illnesses. Here we summarize results demonstrating that the New York City (NYC) subway system provides an important microenvironment for metal exposures for NYC commuters and subway workers and also describe an ongoing pilot study of NYC transit workers' exposure to steel dust. Results from the TEACH (Toxic Exposure Assessment, a Columbia and Harvard) study in 1999 of 41 high-school students strongly suggest that elevated levels of iron, manganese, and chromium in personal air samples were due to exposure to steel dust in the NYC subway. Airborne concentrations of these three metals associated with fine particulate matter were observed to be more than 100 times greater in the subway environment than in home indoor or outdoor settings in NYC. While there are currently no known health effects at the airborne levels observed in the subway system, the primary aim of the ongoing pilot study is to ascertain whether the levels of these metals in the subway air affect concentrations of these metals or related metabolites in the blood or urine of exposed transit workers, who due to their job activities could plausibly have appreciably higher exposures than typical commuters. The study design involves recruitment of 40 transit workers representing a large range in expected exposures to steel dust, the collection of personal air samples of fine particulate matter, and the collection of blood and urine samples from each monitored transit worker.

  17. STS-57 crewmembers examine stowage locker contents during bench review

    NASA Technical Reports Server (NTRS)

    1993-01-01

    STS-57 Endeavour, Orbiter Vehicle (OV) 105, crewmembers, wearing clean suits, examine stowage locker contents during their bench review at Boeing's Flight Equipment Processing Facility (FEPF) located near JSC. Pilot Brian J. Duffy pulls equipment from a locker while Commander Ronald J. Grabe (behind him), Mission Specialist 2 (MS2) Nancy J. Sherlock, Payload Commander (PLC) G. David Low (holding checklist), and MS3 Peter J.K. Wisoff discuss checklist procedures. The crewmembers reviewed equipment locations for OV-105 as well as the SPACEHAB-01 (Commercial Middeck Augmentation Module (CMAM)) experiment stowage locations. Photo taken by NASA JSC contract photographer Benny Benavides.

  18. Ciguatoxin-like substances in edible fish on the eastern Mediterranean.

    PubMed

    Bentur, Yedidia; Spanier, Ehud

    2007-09-01

    The consumption of edible fish (e.g., Siganus spp) was assumed to have caused ciguatera poisoning at an atypical site, the eastern Mediterranean. This pilot study assesses the presence of ciguatoxin-like substances in edible fish on the eastern Mediterranean coast of Israel. Samples of Siganus rivulatus from polluted seawater (Haifa Bay), Siganus rivulatus from relatively clean seawater (Dor), and fish from the freshwater Sea of Galilee not inhabited by toxic algae were analyzed during summertime. Ciguatoxin-like substances were tested by a membrane immunobead assay that yields a color reaction (positive, weakly positive, negative). Significantly more large and small fish from Haifa Bay yielded positive color reactions compared to fish from Dor. Sea of Galilee fish gave no positive color reactions. Our results suggest the presence of ciguatoxin-like substances in edible fish of the eastern Mediterranean. Additional analyses are needed to determine whether these substances are ciguatoxins or related polyethers.

  19. Revision of Viable Environmental Monitoring in a Development Pilot Plant Based on Quality Risk Assessment: A Case Study.

    PubMed

    Ziegler, Ildikó; Borbély-Jakab, Judit; Sugó, Lilla; Kovács, Réka J

    2017-01-01

    In this case study, the principles of quality risk management were applied to review sampling points and monitoring frequencies in the hormonal tableting unit of a formulation development pilot plant. In the cleanroom area, premises of different functions are located. Therefore a general method was established for risk evaluation based on the Hazard Analysis and Critical Control Points (HACCP) method to evaluate these premises (i.e., production area itself and ancillary clean areas) from the point of view of microbial load and state in order to observe whether the existing monitoring program met the emerged advanced monitoring practice. LAY ABSTRACT: In pharmaceutical production, cleanrooms are needed for the manufacturing of final dosage forms of drugs-intended for human or veterinary use-in order to protect the patient's weakened body from further infections. Cleanrooms are premises with a controlled level of contamination that is specified by the number of particles per cubic meter at a specified particle size or number of microorganisms (i.e. microbial count) per surface area. To ensure a low microbial count over time, microorganisms are detected and counted by environmental monitoring methods regularly. It is reasonable to find the easily infected places by risk analysis to make sure the obtained results really represent the state of the whole room. This paper presents a risk analysis method for the optimization of environmental monitoring and verification of the suitability of the method. © PDA, Inc. 2017.

  20. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Looney, J.H.; Im, C.J.

    Under the sponsorship of DOE/METC, UCC Research completed a program in 1984 concerned with the development, testing, and manufacture of an ultra-clean coal-water mixture fuel using the UCC two-stage physical beneficiation and coal-water mixture preparation process. Several gallons of ultra-clean coal-water slurry produced at the UCC Research pilot facility was supplied to DOE/METC for combustion testing. The finalization of this project resulted in the presentation of a conceptual design and economic analysis of an ultra-clean coal-water mixture processing facility sufficient in size to continuously supply fuel to a 100 MW turbine power generation system. Upon completion of the above program,more » it became evident that substantial technological and economic improvement could be realized through further laboratory and engineering investigation of the UCC two-stage physical beneficiation process. Therefore, as an extension to the previous work, the purpose of the present program was to define the relationship between the controlling technical parameters as related to coal-water slurry quality and product price, and to determine the areas of improvement in the existing flow-scheme, associated cost savings, and the overall effect of these savings on final coal-water slurry price. Contents of this report include: (1) introduction; (2) process refinement (improvement of coal beneficiation process, different source coals and related cleanability, dispersants and other additives); (3) coal beneficiation and cost parametrics summary; (4) revised conceptual design and economic analysis; (5) operating and capital cost reduction; (6) conclusion; and (7) appendices. 24 figs., 12 tabs.« less

  1. Feasibility of a Sensory-Adapted Dental Environment for Children With Autism

    PubMed Central

    Stein Duker, Leah I.; Williams, Marian E.; Lane, Christianne Joy; Dawson, Michael E.; Borreson, Ann E.; Polido, José C.

    2015-01-01

    OBJECTIVE. To provide an example of an occupational therapy feasibility study and evaluate the implementation of a randomized controlled pilot and feasibility trial examining the impact of a sensory-adapted dental environment (SADE) to enhance oral care for children with autism spectrum disorder (ASD). METHOD. Twenty-two children with ASD and 22 typically developing children, ages 6–12 yr, attended a dental clinic in an urban hospital. Participants completed two dental cleanings, 3–4 mo apart, one in a regular environment and one in a SADE. Feasibility outcome measures were recruitment, retention, accrual, dropout, and protocol adherence. Intervention outcome measures were physiological stress, behavioral distress, pain, and cost. RESULTS. We successfully recruited and retained participants. Parents expressed satisfaction with research study participation. Dentists stated that the intervention could be incorporated in normal practice. Intervention outcome measures favored the SADE condition. CONCLUSION. Preliminary positive benefit of SADE in children with ASD warrants moving forward with a large-scale clinical trial. PMID:25871593

  2. Oral health knowledge, behavior, and care seeking among pregnant and recently-delivered women in rural Nepal: a qualitative study.

    PubMed

    Lubon, A J; Erchick, D J; Khatry, S K; LeClerq, S C; Agrawal, N K; Reynolds, M A; Katz, J; Mullany, L C

    2018-06-01

    Oral health behavior and attitudes of pregnant women in low-income countries are rarely examined, yet should be considered when designing preventative or therapeutic studies to reduce burden of oral diseases. We aimed to understand dental care-seeking behavior, as well as oral health knowledge and attitudes of oral health among pregnant women in rural Nepal. Semi-structured in-depth interviews (n = 16) and focus group discussions (3 groups, n = 23) were conducted among pregnant and recently-delivered women in Sarlahi, Nepal. Transcripts were translated from the local language to English then analyzed using a hybrid approach to thematic coding with Atlas.ti version 7. Women felt confident describing the signs and symptoms of tooth decay and gum disease, but were not knowledgeable about where to receive care for tooth and/or gum pain and relied heavily on the knowledge of their community. Some women used a toothbrush and toothpaste at least once a day to clean their teeth, but many reported the traditional use of a branch of a local shrub or tree as their teeth cleaning instrument. Women suggested a willingness to consider using an oral rinse throughout pregnancy, perceiving that it might have a positive impact on infant health. Future studies should focus on providing adequate and sustainable resources for pregnant women in Nepal and other low income settings to engage in good oral health behaviors (possibly supported through community-based workers), to maintain dental hygiene, and to access qualified dentists as a means of improving their oral health. ClinicalTrials.gov Identifier: NCT01177111 (Nepal Oil Massage Study) and NCT02788786 (Pilot Trial).

  3. Advanced in-duct sorbent injection for SO{sub 2} control. Topical report No. 2, Subtask 2.2: Design optimization

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rosenhoover, W.A.; Stouffer, M.R.; Withum, J.A.

    1994-12-01

    The objective of this research project is to develop second-generation duct injection technology as a cost-effective SO{sub 2} control option for the 1990 Clean Air Act Amendments. Research is focused on the Advanced Coolside process, which has shown the potential for achieving the performance targets of 90% SO{sub 2} removal and 60% sorbent utilization. In Subtask 2.2, Design Optimization, process improvement was sought by optimizing sorbent recycle and by optimizing process equipment for reduced cost. The pilot plant recycle testing showed that 90% SO{sub 2} removal could be achieved at sorbent utilizations up to 75%. This testing also showed thatmore » the Advanced Coolside process has the potential to achieve very high removal efficiency (90 to greater than 99%). Two alternative contactor designs were developed, tested and optimized through pilot plant testing; the improved designs will reduce process costs significantly, while maintaining operability and performance essential to the process. Also, sorbent recycle handling equipment was optimized to reduce cost.« less

  4. Pilot-scale demonstration of phytofiltration for treatment of arsenic in New Mexico drinking water.

    PubMed

    Elless, Mark P; Poynton, Charissa Y; Willms, Cari A; Doyle, Mike P; Lopez, Alisa C; Sokkary, Dale A; Ferguson, Bruce W; Blaylock, Michael J

    2005-10-01

    Arsenic contamination of drinking water poses serious health risks to millions of people worldwide. To reduce such risks, the United States Environmental Protection Agency recently lowered the Maximum Contaminant Level for arsenic in drinking water from 50 to 10 microgL(-1). The majority of water systems requiring compliance are small systems that serve less than 10,000 people. Current technologies used to clean arsenic-contaminated water have significant drawbacks, particularly for small treatment systems. In this pilot-scale demonstration, we investigated the use of arsenic-hyperaccumulating ferns to remove arsenic from drinking water using a continuous flow phytofiltration system. Over the course of a 3-month demonstration period, the system consistently produced water having an arsenic concentration less than the detection limit of 2 microgL(-1), at flow rates as high as 1900 L day(-1) for a total treated water volume of approximately 60,000 L. Our results demonstrate that phytofiltration provides the basis for a solar-powered hydroponic technique to enable small-scale cleanup of arsenic-contaminated drinking water.

  5. A flight management algorithm and guidance for fuel-conservative descents in a time-based metered air traffic environment: Development and flight test results

    NASA Technical Reports Server (NTRS)

    Knox, C. E.

    1984-01-01

    A simple airborne flight management descent algorithm designed to define a flight profile subject to the constraints of using idle thrust, a clean airplane configuration (landing gear up, flaps zero, and speed brakes retracted), and fixed-time end conditions was developed and flight tested in the NASA TSRV B-737 research airplane. The research test flights, conducted in the Denver ARTCC automated time-based metering LFM/PD ATC environment, demonstrated that time guidance and control in the cockpit was acceptable to the pilots and ATC controllers and resulted in arrival of the airplane over the metering fix with standard deviations in airspeed error of 6.5 knots, in altitude error of 23.7 m (77.8 ft), and in arrival time accuracy of 12 sec. These accuracies indicated a good representation of airplane performance and wind modeling. Fuel savings will be obtained on a fleet-wide basis through a reduction of the time error dispersions at the metering fix and on a single-airplane basis by presenting the pilot with guidance for a fuel-efficient descent.

  6. Ultrasonic frequency selection for aqueous fine cleaning

    NASA Technical Reports Server (NTRS)

    Becker, Joann F.

    1995-01-01

    A study was conducted to evaluate ultrasonic cleaning systems for precision cleaning effectiveness for oxygen service hardware. This evaluation was specific for Rocketdyne Division of Rockwell Aerospace alloys and machining soils. Machining lubricants and hydraulic fluid were applied as soils to standardized complex test specimens designed to simulate typical hardware. The study consisted of tests which included 20, 25, 30, 40, 50, and 65 kHz ultrasonic cleaning systems. Two size categories of cleaning systems were evaluated, 3- to 10-gal laboratory size tanks and 35- to 320-gal industrial size tanks. The system properties of cavitation, frequency vs. cleaning effectiveness, the two types of transducers, and the power level of the system vs. size of the cleaning tank were investigated. The data obtained from this study was used to select the ultrasonic tanks for the aqueous fine clean facility installed at Rocketdyne.

  7. Ultrasonic frequency selection for aqueous fine cleaning

    NASA Technical Reports Server (NTRS)

    Becker, Joann F.

    1994-01-01

    A study was conducted to evaluate ultrasonic cleaning systems for precision cleaning effectiveness for oxygen service hardware. This evaluation was specific for Rocketdyne Div. of Rockwell Aerospace alloys and machining soils. Machining lubricants and hydraulic fluid were applied as soils to standardized complex test specimens designed to simulate typical hardware. The study consisted of tests which included 20, 25, 30, 40, 50, and 65 kHz ultrasonic cleaning systems. Two size categories of cleaning systems were evaluated, 3- to 10-gal laboratory size tanks and 35- to 320-gal industrial size tanks. The system properties of cavitation; frequency vs. cleaning effectiveness; the two types of transducers; and the power level of the system vs. size of the cleaning tank were investigated. The data obtained from this study was used to select the ultrasonic tanks for the aqueous fine clean facility installed at Rocketdyne.

  8. Gaseous emissions from sewage sludge combustion in a moving bed combustor.

    PubMed

    Batistella, Luciane; Silva, Valdemar; Suzin, Renato C; Virmond, Elaine; Althoff, Chrtistine A; Moreira, Regina F P M; José, Humberto J

    2015-12-01

    Substantial increase in sewage sludge generation in recent years requires suitable destination for this residue. This study evaluated the gaseous emissions generated during combustion of an aerobic sewage sludge in a pilot scale moving bed reactor. To utilize the heat generated during combustion, the exhaust gas was applied to the raw sludge drying process. The gaseous emissions were analyzed both after the combustion and drying steps. The results of the sewage sludge characterization showed the energy potential of this residue (LHV equal to 14.5 MJ kg(-1), db) and low concentration of metals, polycyclic aromatic hydrocarbons (PAH), polychlorinated dibenzo-p-dioxins (PCDD) and polychlorinated dibenzofurans (PCDF). The concentration of CO, NOx, BTEX (benzene, toluene, ethylbenzene and xylenes) emitted from the sludge combustion process were lower than the legal limits. The overall sludge combustion and drying process showed low emissions of PCDD/PCDF (0.42 ng I-TEQ N m(-3)). BTEX and PAH emissions were not detected. Even with the high nitrogen concentration in the raw feed (5.88% db), the sludge combustion process presented NOx emissions below the legal limit, which results from the combination of appropriate feed rate (A/F ratio), excess air, and mainly the low temperature kept inside the combustion chamber. It was found that the level of CO emissions from the overall sludge process depends on the dryer operating conditions, such as the oxygen content and the drying temperature, which have to be controlled throughout the process in order to achieve low CO levels. The aerobic sewage sludge combustion process generated high SO2 concentration due to the high sulfur content (0.67 wt%, db) and low calcium concentration (22.99 g kg(-1)) found in the sludge. The high concentration of SO2 in the flue gas (4776.77 mg N m(-3)) is the main factor inhibiting PCDD/PCDF formation. Further changes are needed in the pilot plant scheme to reduce SO2 and particulate matter emissions, such as the installation of exhaust gas-cleaning systems. According to previous studies, the efficient operation of such cleaning systems is also effective for metals emission control, which makes the combustion of sewage sludge a feasible treatment method from both energetic and environmental perspectives. Copyright © 2015 Elsevier Ltd. All rights reserved.

  9. A Commercial IOTV Cleaning Study

    DTIC Science & Technology

    2010-04-12

    manufacturer’s list price without taking into consideration of possible volume discount.  Equipment depreciation cost was calculated based on...Laundering with Prewash Spot Cleaning) 32 Table 12 Shrinkage Statistical Data (Traditional Wet Laundering without Prewash Spot Cleaning...Statistical Data (Computer-controlled Wet Cleaning without Prewash Spot Cleaning) 35 Table 15 Shrinkage Statistical Data (Liquid CO2 Cleaning

  10. Efficacy of Detergent and Water Versus Bleach for the Disinfection of Direct Contact Ophthalmic Lenses

    PubMed Central

    Abbey, Ashkan M.; Gregori, Ninel Z.; Surapaneni, Krishna; Miller, Darlene

    2014-01-01

    Purpose While manufacturers recommend cleaning ophthalmic lenses with detergent and water and then a specific disinfectant, disinfectants are rarely used in ophthalmic practices. The aim of this pilot study was to evaluate the efficacy of detergent and water versus bleach, a recommended disinfectant, to eliminate common ocular bacteria and viruses from ophthalmic lenses. Methods Three bacterial strains (Staphylococcus epidermidis, Corynebacterium straitum, and methicillin-resistant Staphylococcus aureus (MRSA) and two viral strains (adenovirus and herpes simplex virus (HSV) type-1) were individually inoculated to 20 gonioscopy and laser lenses. Lenses were washed with detergent and water and then disinfected with 10% bleach. All lenses were cultured after inoculation, after detergent and water, and after the bleach. Bacterial cultures in thioglycollate broth were observed for 3 weeks and viral cultures for 2 weeks. The presence of viruses was also detected by multiplex polymerase chain reaction (PCR). Results All 20 lenses inoculated with Staphylococcus epidermidis, Corynebacterium straitum, adenovirus, and HSV-1 showed growth after inoculation, but no growth after detergent/water and after the bleach. All lenses showed positive HSV and adenovirus PCR after inoculation and negative PCR after detergent/water and after bleach. All MRSA contaminated lenses showed growth after inoculation and no growth after detergent and water. However, one lens showed positive growth after bleach. Conclusions Cleaning with detergent and water appeared to effectively eliminate bacteria and viruses from the surface of contaminated ophthalmic lenses. Further studies are warranted to design practical disinfection protocols that minimize lens damage. PMID:24747806

  11. Estimation of the safe use concentrations of the preservative 1,2-benzisothiazolin-3-one (BIT) in consumer cleaning products and sunscreens.

    PubMed

    Novick, Rachel M; Nelson, Mindy L; Unice, Kenneth M; Keenan, James J; Paustenbach, Dennis J

    2013-06-01

    1,2-Benzisothiazolin-3-one (BIT; CAS # 2634-33-5) is a preservative used in consumer products. Dermal exposure to BIT at sufficient dose and duration can produce skin sensitization and allergic contact dermatitis in animals and susceptible humans.The purpose of this study is to derive a maximal concentration of BIT in various consumer products that would result in exposures below the No Expected Sensitization Induction Level (NESIL), a dose below which skin sensitization should not occur. A screening level exposure estimate was performed for several product use scenarios with sunscreen, laundry detergent, dish soap, and spray cleaner. We calculated that BIT concentrations below the following concentrations of 0.0075%, 0.035%, 0.035%, 0.021% in sunscreen, laundry detergent, dish soap, and spray cleaner, respectively, are unlikely to induce skin sensitization. We completed a pilot study consisting of bulk sample analysis of one representative product from each category labelled as containing BIT, and found BIT concentrations of 0.0009% and 0.0027% for sunscreen and dish soap, respectively. BIT was not detected in the laundry detergent and spray cleaner products above the limit of detection of 0.0006%. Based on publically available data for product formulations and our results, we were able to establish that cleaning products and sunscreens likely contain BIT at concentrations similar to or less than our calculated maximal safe concentrations and that exposures are unlikely to induce skin sensitization in most users. Copyright © 2013 Elsevier Ltd. All rights reserved.

  12. Comparative Mirror Cleaning Study: 'A Study on Removing Particulate Contamination'

    NASA Technical Reports Server (NTRS)

    Houston, Karrie

    2007-01-01

    The cleanliness of optical surfaces is recognized as an industry-wide concern for the performance of optical devices such as mirrors and telescopes, microscopes and lenses, lasers and interferometers, and prisms and optical filters. However, no standard has been established for optical cleaning and there is no standard definition of a 'clean' optical element. This study evaluates the effectiveness of commonly used optical cleaning techniques based on wafer configuration, contamination levels, and the number and size of removed particles. It is concluded that cleaning method and exposure time play a significant factor in obtaining a high removal percentage. The detergent bath and solvent rinse method displayed an increase in effective removal percentage as the contamination exposure increased. Likewise, CO2 snow cleaning showed a relatively consistent cleaning effectiveness. The results can help ensure mission success to flight projects developed for the NASA Origins Program. Advantages and disadvantages of each of the optical cleaning methods are described.

  13. Update on asthma and cleaners

    PubMed Central

    Zock, Jan-Paul; Vizcaya, David; Le Moual, Nicole

    2010-01-01

    Purpose of review This paper summarises the recent literature on the relation between cleaning exposures and respiratory health, in particular asthma, including reviews, epidemiological surveys, surveillance programmes and exposure studies. The authors also aimed to identify gaps in the current knowledge and to recommend future research on the topic. Recent findings A large international general population study showed an increased risk of new-onset asthma associated with cleaning work, with professional use of cleaning products, and with domestic use of cleaning sprays. Three surveillance studies confirm the recognition of occupational asthma cases among cleaners and among others who use cleaning products at work. Six workforce-based studies show that respiratory symptoms are partly work-related, and are associated with certain specific exposures including sprays, chlorine bleach and other disinfectants. Summary Recent studies have strengthened the evidence of asthma and other adverse respiratory effects in cleaning workers. Similar effects were seen in other settings where cleaning products are used such as healthcare professionals and homemakers. Both new-onset asthma and work-exacerbated asthma due to cleaning exposures may play a role. Exposure to cleaning sprays, chlorine bleach and other disinfectants may be particularly relevant. The predominant effect mechanisms remain largely unclear and may include both specific sensitisation and irritant-related features. PMID:20093933

  14. A climate risk assessment of clean water supply in an urban area: A case study of South Tangerang city, Indonesia

    NASA Astrophysics Data System (ADS)

    Nastiti, S. I. W.; Kusnoputranto, H.; Boer, R.; Utomo, S. W.

    2018-03-01

    The demand for clean water in South Tangerang, Indonesia, is very high. At present, this demand is mostly met by groundwater that is much influenced by climate variability, land cover change, and human activities. The local company on water services (PDAM) provides clean water services for only about 9% of the population. The climate risk assessment conducted by South Tangerang Government in 2016 indicates that several areas are potentially exposed to a high risk of climate change. Survey and in-depth interview with communities and sectoral officers suggest that a risk to clean water supply in this city is increasing. This study aims to assess climate potential risks on clean water supply based on the 2016 study. We adopted the method of that study by modifying some of the vulnerability indicators that can represent clean water access and supply. The results of the study demonstrate that many wards in South Tangerang would be exposed to high climate risks of clean water supply. By 2021, about 54% of wards would be exposed from high to the very very high risk of clean water supply. These results signify the tangible need of adaptation actions, to prevent the worsening impacts of climate on clean water supply.

  15. From Results to Action - Implementing an Indoor Air Quality Pilot Project

    NASA Astrophysics Data System (ADS)

    Collier, A. M.; Ware, G. E.; Iwasaki, P. G.; Billingsley, L. R.; Main, D.; Hannigan, M.; Pfotenhauer, D.

    2016-12-01

    One of the key differences between community-based participatory research (CBPR) and more conventional scientific research is the expectation that a project does not end with finalized results, but rather with taking action based on those results. Using an indoor air quality pilot project as an example, we will discuss how the consideration of potential actions and applications for the project findings should be integrated into planning throughout the life of a project. We will also share general reflections on effective CBPR from the perspective of both science and community partners on the project. In 2015, Taking Neighborhood Health to Heart (TNH2H), a community-based organization in Northeast Denver, researchers from the University of Colorado, Boulder, and AGU's Thriving Earth Exchange partnered to conduct a pilot project investigating indoor air quality in a Denver community. This partnership formed in response to community concerns about potential environmental contamination from dry cleaning operations, specifically through spills of the compound perchloroethylene. The exploration of the presence of radon, another indoor air quality concern common across the state of Colorado, was also added to the project. Using an iterative process, the team designed a sampling plan, selected a target location, and recruited homes and residents to participate in the pilot project. Radon and perchloroethylene data were then collected in 15 homes. Following data collection, results were first shared with project participants, after which de-identified data were shared with the members of TNH2H. Together TNH2H and researchers then developed strategies for public dissemination of the project findings. While we did not find levels of percholorethylene above the `action level' in any of the participating homes; however, we did find more frequent occurrences of radon levels above the `action level' than we had anticipated. For example, 80% of the homes in our study had radon levels requiring remediation while the reported average percentage for the Denver County is only 40% of homes. These results are currently driving our partnership to pursue actions that will lower residents' exposure to radon and improve public health in the TNH2H communities.

  16. Effect of operation parameters on the flux stabilization of gravity-driven membrane (GDM) filtration system for decentralized water supply.

    PubMed

    Tang, Xiaobin; Ding, An; Qu, Fangshu; Jia, Ruibao; Chang, Haiqing; Cheng, Xiaoxiang; Liu, Bin; Li, Guibai; Liang, Heng

    2016-08-01

    A pilot-scale gravity-driven membrane (GDM) filtration system under low gravitational pressure without any pre-treatment, backwash, flushing, or chemical cleaning was carried out to investigate the effect of operation parameters (including operation pressure, aeration mode, and intermittent filtration) on the effluent quality and permeability development. The results revealed that GDM system exhibited an efficient performance for the removal of suspended substances and organic compounds. The stabilization of flux occurred and the average values of stable flux were 6.6, 8.1, and 8.6 Lm(-2) h(-1) for pressures of 65, 120, and 200 mbar, respectively. In contrast, flux stabilization was not observed under continuous and intermittent aeration conditions. However, aeration (especially continuous aeration) was effective to improve flux and alleviate membrane fouling during 1-month operation. Moreover, intermittent filtration would influence the stabilization of permeate flux, resulting in a higher stable flux (ranging from 6 to 13 Lm(-2) h(-1)). The stable flux significantly improved with the increase of intermittent period. Additionally, GDM systems exhibited an efficient recovery of flux after simple physical cleaning and the analyses of resistance reversibility demonstrated that most of the total resistance was hydraulic reversible resistance (50-75 %). Therefore, it is expected that the results of this study can develop strategies to increase membrane permeability and reduce energy consumption in GDM systems for decentralized water supply.

  17. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cowlin, S.; Cochran, J.; Cox, S.

    Low emission development strategies (LEDS) articulate policies and implementation plans that enable countries to advance sustainable, climate-resilient development and private sector growth while significantly reducing the greenhouse gas (GHG) emissions traditionally associated with economic growth. In creating a LEDS, policy makers often have access to information on abatement potential and costs for clean energy technologies, but there is a scarcity of economy-wide approaches for evaluating and presenting information on other dimensions of importance to development, such as human welfare, poverty alleviation, and energy security. To address this shortcoming, this paper proposes a new tool for communicating development benefits to policymore » makers as part of a LEDS process. The purpose of this tool is two-fold: 1. Communicate development benefits associated with each clean energy-related intervention; 2. Facilitate decision-making on which combination of interventions best contributes to development goals. To pilot this tool, the authors created a visual using data on developmental impacts identified through the Technology Needs Assessment (TNA) project in Montenegro. The visual will then be revised to reflect new data established through the TNA that provides information on cost, GHG mitigation, as well as the range and magnitude of developmental impacts.« less

  18. Microbial Removal of the Pharmaceutical Compounds Ibuprofen and Diclofenac from Wastewater

    PubMed Central

    Inderfurth, Nadia; Schraa, Gosse; Kujawa-Roeleveld, Katarzyna; Rijnaarts, Huub

    2013-01-01

    Studies on the occurrence of pharmaceuticals show that the widely used pharmaceuticals ibuprofen and diclofenac are present in relevant concentrations in the environment. A pilot plant treating hospital wastewater with relevant concentrations of these pharmaceuticals was evaluated for its performance to reduce the concentration of the pharmaceuticals. Ibuprofen was completely removed, whereas diclofenac yielded a residual concentration, showing the necessity of posttreatment to remove diclofenac, for example, activated carbon. Successively, detailed laboratory experiments with activated sludge from the same wastewater treatment plant showed bioremediation potential in the treatment plant. The biological degradation pathway was studied and showed a mineralisation of ibuprofen and degradation of diclofenac. The present microbes were further studied in laboratory experiments, and DGGE analyses showed the enrichment and isolation of highly purified cultures that degraded either ibuprofen or diclofenac. This research illuminates the importance of the involved bacteria for the effectiveness of the removal of pharmaceuticals in a wastewater treatment plant. A complete removal of pharmaceuticals from wastewater will stimulate water reuse, addressing the worldwide increasing demand for clean and safe fresh water. PMID:24350260

  19. A pilot study to assess the bacterial contaminants in hookah pipes in a community setting.

    PubMed

    Martinasek, M; Rivera, Z; Ferrer, A; Freundt, E

    2018-05-01

    Hookah smoking among young adults remains a public health threat. Increasing research has uncovered the deleterious effects of hookah smoking, including both acute and chronic health conditions. Due to the current lack of regulation, hookah bars/lounges lack protocols for equipment sanitation. To examine evidence of bacterial contamination in hookah pipes due to a lack of sanitation regulations. For this field/laboratory study, 10 hookah bars/lounges were studied. Isolated bacteria were characterized and identified by species using 16S ribosomal RNA gene sequencing. At the 10 hookah bars sampled, the mouthpiece had the highest bacterial prevalence and diversity. Some of the bacterial isolates were found to be antibiotic-resistant. Ten of the isolated bacteria were Gram-positive and two were identified as Gram-negative. Levels of bacterial contamination vary widely from one hookah bar to the next, and reflect a lack of industry standards for cleaning these devices. Bacterial contamination of hookah pipes may represent a fomite for transmission of infectious diseases. Our results warrant future surveillance of hookahs to monitor for potential human pathogens.

  20. Cleaning Management in Higher Education: Value for Money Study.

    ERIC Educational Resources Information Center

    Scottish Higher Education Funding Council, Edinburgh.

    This report identifies key management issues for senior managers and heads of cleaning departments in developing and reviewing cleaning services to support improvement and enhance cost effectiveness. The cleaning costs incurred by higher education institutions (HEIs) represent 2.7 percent of the total spent nationally on cleaning services for both…

  1. A pilot study of bioaerosol reduction using an air cleaning system during dental procedures.

    PubMed

    Hallier, C; Williams, D W; Potts, A J C; Lewis, M A O

    2010-10-23

    Bioaerosols are defined as airborne particles of liquid or volatile compounds that contain living organisms or have been released from living organisms. The creation of bioaerosols is a recognized consequence of certain types of dental treatment and represents a potential mechanism for the spread of infection. The aims of the present study were to assess the bioaerosols generated by certain dental procedures and to evaluate the efficiency of a commercially available Air Cleaning System (ACS) designed to reduce bioaerosol levels. Bioaerosol sampling was undertaken in the absence of clinical activity (baseline) and also during treatment procedures (cavity preparation using an air rotor, history and oral examination, ultrasonic scaling and tooth extraction under local anaesthesia). For each treatment, bioaerosols were measured for two patient episodes (with and without ACS operation) and between five and nine bioaerosol samples were collected. For baseline measurements, 15 bioaerosol samples were obtained. For bioaerosol sampling, environmental air was drawn on to blood agar plates using a bioaerosol sampling pump placed in a standard position 20 cm from the dental chair. Plates were incubated aerobically at 37°C for 48 hours and resulting growth quantified as colony forming units (cfu/m³). Distinct colony types were identified using standard methods. Results were analysed statistically using SPSS 12 and Wilcoxon signed rank tests. The ACS resulted in a significant reduction (p = 0.001) in the mean bioaerosols (cfu/m³) of all three clinics compared with baseline measurements. The mean level of bioaerosols recorded during the procedures, with or without the ACS activated respectively, was 23.9 cfu/m³ and 105.1 cfu/m³ (p = 0.02) for cavity preparation, 23.9 cfu/m³ and 62.2 cfu/m³ (p = 0.04) for history and oral examination; 41.9 cfu/m³ and 70.9 cfu/m³ (p = 0.01) for ultrasonic scaling and 9.1 cfu/m³ and 66.1 cfu/m³ (p = 0.01) for extraction. The predominant microorganisms isolated were Staphylococcus species and Micrococcus species. These findings indicate potentially hazardous bioaerosols created during dental procedures can be significantly reduced using an air cleaning system.

  2. KEY COMPARISON: CCQM-K32 key comparison and P84 pilot study: Amount of silicon oxide as a thickness of SiO2 on Si

    NASA Astrophysics Data System (ADS)

    Seah, M. P.

    2008-01-01

    CCQM-K32 and P84 were conducted following the pilot study P-38 to demonstrate and document the capability of interested National Metrology Institutes to measure the amount of silicon oxide on silicon wafers expressed as a thickness of SiO2 for nominal thicknesses in the range 1.5 nm to 8 nm. 'Amount of substance' may be expressed in many ways and here the measurand is the thickness of the silicon oxide layer on each of a total of 9 samples of nominal thicknesses in the range 1.5 to 8 nm on (100) and (111) Si substrates, expressed as the thickness of SiO2. This report presents the results from K32 and P84. It includes the data received for the measured values and their associated uncertainties, at 95% confidence, for the 9 samples prior to the deadline for receipt of data. The materials are grown by thermal oxidation in very clean furnaces designed for high quality gate oxides on Si wafers in European and US facilities at the same time as those for the pilot study, P-38. Separate samples were provided to each institute in special containers limiting the carbonaceous contamination to below about 0.3 nm. The 9 samples included 5 samples of ultra-thin SiO2 on (100) orientated wafers of Si and 4 samples of ultra-thin SiO2 on (111) orientated wafers of Si. The measurements from the 11 participating laboratories were conducted using ellipsometry, neutron reflectivity (NR), x-ray photoelectron spectroscopy (XPS) or x-ray reflectivity measurements (XRR), guided by the protocol developed in the pilot study P-38 and reproduced in the Appendix. The measurements are given in tables 2 and 3. A very small correction is then made for the different samples that each laboratory received as in table 4. Where appropriate, method offset values deduced from the pilot study P-38 are given in table 5 leading to comparative data in tables 6 and 7. Values for the key comparison reference values (KCRVs) and their associated uncertainties are made from the weighted means and the expanded weighted standard deviations of the means from table 6. This is provided in table 8. Graphical plots of equivalence from tables 6 and 8 are provided in figure 1 and equivalence statements are presented in Annex A. Additional XPS and XRR data from NMIJ for K32 were withdrawn from the KCRV evaluation and are given in Annex B. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  3. Knowledge of Oral Health Issues Among Low–Income Baltimore Adults: A Pilot Study

    PubMed Central

    Macek, Mark D.; Manski, Marion C.; Schneiderman, MaryAnn T.; Meakin, Sarah J.; Haynes, Don; Wells, William; Bauer–Leffler, Simon; Cotten, P. Ann; Parker, Ruth M.

    2013-01-01

    Purpose This pilot study documents conceptual knowledge of oral health among low–income adults in Baltimore. Methods Selected questions from the Baltimore Health Literacy and Oral Health Knowledge Project, a cross–sectional, population–based investigation of oral health literacy, were used for this analysis. Participants were asked questions during face–to–face interviews about basic oral health and the prevention and management of dental caries and periodontal diseases. Descriptive analyses included tests of association with selected socio–demographic variables (age, sex, education level, annual household income). Results The majority of respondents were African American women, 45 to 64 years of age, with 12 years of education and an income less than or equal to $25,000. Ninety–one percent of respondents knew that sugar caused dental caries, while 82% understood that the best way to prevent tooth decay was to brush and floss every day. Knowledge of oral hygiene practices and the prevention and management of gingivitis and periodontitis was mixed. Seventy–six percent understood that the best way to remove tartar was by a dental cleaning. However, only 15% knew how often to floss their teeth and only 21% knew that plaque was composed of germs. Conclusion Conceptual oral health knowledge is one component of oral health literacy. In turn, oral health literacy impacts communication. Practitioners should account for limited conceptual knowledge when they discuss oral health issues with their low–income and minority patients. If this is not accounted for, they will probably find that their oral hygiene education messages are being ignored and health promotion is being adversely affected. PMID:21396263

  4. Can Beach Cleans Do More Than Clean-Up Litter? Comparing Beach Cleans to Other Coastal Activities

    PubMed Central

    Wyles, Kayleigh J.; Pahl, Sabine; Holland, Matthew; Thompson, Richard C.

    2016-01-01

    Coastal visits not only provide psychological benefits but can also contribute to the accumulation of rubbish. Volunteer beach cleans help address this issue, but may only have limited, local impact. Consequently, it is important to study any broader benefits associated with beach cleans. This article examines the well-being and educational value of beach cleans, as well as their impacts on individuals’ behavioral intentions. We conducted an experimental study that allocated students (n = 90) to a beach cleaning, rock pooling, or walking activity. All three coastal activities were associated with positive mood and pro-environmental intentions. Beach cleaning and rock pooling were associated with higher marine awareness. The unique impacts of beach cleaning were that they were rated as most meaningful but linked to lower restorativeness ratings of the environment compared with the other activities. This research highlights the interplay between environment and activities, raising questions for future research on the complexities of person-environment interactions. PMID:28546642

  5. Cross-sectional study of frequency and factors associated with stethoscope cleaning among medical practitioners in Pakistan.

    PubMed

    Hyder, O

    2012-07-01

    Stethoscope diaphragms are frequently colonized by bacteria. This cross-sectional study described the frequency and factors associated with reporting ever cleaning stethoscopes among 408 medical students and doctors at a medical college and 2 teaching hospitals in Rawalpindi, Pakistan. A minority of the respondents (37.7%) reported having ever cleaned their stethoscope. Following normal clinical use, wiping with a dry cloth was the most frequently reported method of cleaning (53.2%). After contamination of the diaphragm with blood or secretions, cleaning with an alcoholic swab was the most common method (64.3%). In univariate and multivariate analyses, history of receiving information on stethoscope cleaning, utilization of personal stethoscope at last use and affiliation with internal medicine department were factors strongly associated with ever cleaning of stethoscope. Future research for improving stethoscope cleaning practices should explore educational interventions aimed at health care professionals.

  6. Manual cleaning of hospital mattresses: an observational study comparing high- and low-resource settings.

    PubMed

    Hopman, J; Hakizimana, B; Meintjes, W A J; Nillessen, M; de Both, E; Voss, A; Mehtar, S

    2016-01-01

    Hospital-associated infections (HAIs) are more frequently encountered in low- than in high-resource settings. There is a need to identify and implement feasible and sustainable approaches to strengthen HAI prevention in low-resource settings. To evaluate the biological contamination of routinely cleaned mattresses in both high- and low-resource settings. In this two-stage observational study, routine manual bed cleaning was evaluated at two university hospitals using adenosine triphosphate (ATP). Standardized training of cleaning personnel was achieved in both high- and low-resource settings. Qualitative analysis of the cleaning process was performed to identify predictors of cleaning outcome in low-resource settings. Mattresses in low-resource settings were highly contaminated prior to cleaning. Cleaning significantly reduced biological contamination of mattresses in low-resource settings (P < 0.0001). After training, the contamination observed after cleaning in both the high- and low-resource settings seemed comparable. Cleaning with appropriate type of cleaning materials reduced the contamination of mattresses adequately. Predictors for mattresses that remained contaminated in a low-resource setting included: type of product used, type of ward, training, and the level of contamination prior to cleaning. In low-resource settings mattresses were highly contaminated as noted by ATP levels. Routine manual cleaning by trained staff can be as effective in a low-resource setting as in a high-resource setting. We recommend a multi-modal cleaning strategy that consists of training of domestic services staff, availability of adequate time to clean beds between patients, and application of the correct type of cleaning products. Copyright © 2015 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  7. Mechanics of load-drag-unload contact cleaning of gecko-inspired fibrillar adhesives.

    PubMed

    Abusomwan, Uyiosa A; Sitti, Metin

    2014-10-14

    Contact self-cleaning of gecko-inspired synthetic adhesives with mushroom-shaped tips has been demonstrated recently using load-drag-unload cleaning procedures similar to that of the natural animal. However, the underlying mechanics of contact cleaning has yet to be fully understood. In this work, we present a detailed experiment of contact self-cleaning that shows that rolling is the dominant mechanism of cleaning for spherical microparticle contaminants, during the load-drag-unload procedure. We also study the effect of dragging rate and normal load on the particle rolling friction. A model of spherical particle rolling on an elastomer fibrillar adhesive interface is developed and agrees well with the experimental results. This study takes us closer to determining design parameters for achieving self-cleaning fibrillar adhesives.

  8. The substitution of sand filtration by immersed-UF for surface water treatment: pilot-scale studies.

    PubMed

    Lihua, Sun; Xing, Li; Guoyu, Zhang; Jie, Chen; Zhe, Xu; Guibai, Li

    2009-01-01

    The newly issued National Drinking Water Standard required that turbidity should be lower than 1 NTU, and the substitution of sand filtration by immersed ultrafiltration (immersed-UF) is feasible to achieve the standard. This study aimed to optimise the operational processes (i.e. aeration, backwashing) through pilot scale studies, to control membrane fouling while treating the sedimentation effluent. Results indicated that the immersed-UF was promising to treat the sedimentation effluent. The turbidity was below 0.10 NTU, bacteria and E. coli were not detected in the permeate water. The intermittent filtration with aeration is beneficial to inhibit membrane fouling. The critical aeration intensity is observed to be 60.0 m(3) m(-2) h(-1). At this aeration intensity, the decline rate of permeate flux in one period of backwashing was 1.94% and 7.03% for intermittent filtration and sustained filtration respectively. The different membrane backwashing methods (i.e. aeration 1.5 min, synchronous aeration and water backwashing 2 min, water backwashing 1.5 min; synchronous aeration and water backwashing 3 min, water backwashing 2 min; aeration 3 min, single water backwashing 2 min; synchronous aeration and water backwashing 5 min; single water backwashing 5 min) on the recovery of permeate flux were compared, indicating that the synchronous aeration and water backwashing exhibited best potential for permeate flux recovery. The optimal intensity of water backwashing is shown to be 90.0 L m(-2) h(-1). When the actual water intensity was below or exceeded the value, the recovery rate of permeate flux would be reduced. Additionally, the average operating cost for the immersed UF membrane, including the power, the chemical cleaning reagents, and membrane modules replacement, was about 0.31 RMB/m(3).

  9. Laser Ablation Cleaning of Self-Reacting Friction Stir Weld Seam Surfaces: A Preliminary Evaluation

    NASA Technical Reports Server (NTRS)

    Nunes, A. C., Jr.; Russell, C. K.; Brooke, S. A.; Parry, Q.; Lowrey, N. M.

    2014-01-01

    Anodized aluminum panels were cleaned by three lasers at three separate sites with a view to determining whether more economical laser cleaning might supplant current manual cleaning methods for preparation of surfaces to be welded by the self-reacting friction stir process. Uncleaned panels yielded welds exhibiting residual oxide defect (ROD) and failing at very low stresses along the trace of the weld seam. Manually cleaned panels yielded welds without ROD; these welds failed at nominal stress levels along an angled fracture surface not following the weld seam trace. Laser cleaned panels yielded welds failing at intermediate stress levels. The inadequacy of the laser cleaning processes leaves questions: Was the anodized aluminum test too stringent to represent actual cleaning requirements? Were the wrong laser cleaning techniques/parameters used for the study? Is the laser cleaning mechanism inadequate for effective preweld surface cleaning?

  10. Chemical cleaning/disinfection and ageing of organic UF membranes: a review.

    PubMed

    Regula, C; Carretier, E; Wyart, Y; Gésan-Guiziou, G; Vincent, A; Boudot, D; Moulin, P

    2014-06-01

    Membrane separation processes have become a basic unit operation for process design and product development. These processes are used in a variety of separation and concentration steps, but in all cases, the membranes must be cleaned regularly to remove both organic and inorganic material deposited on the surface and/or into the membrane bulk. Cleaning/disinfection is a vital step in maintaining the permeability and selectivity of the membrane in order to get the plant to its original capacity, to minimize risks of bacteriological contamination, and to make acceptable products. For this purpose, a large number of chemical cleaning/disinfection agents are commercially available. In general, these cleaning/disinfection agents have to improve the membrane flux to a certain extent. However, they can also cause irreversible damages in membrane properties and performances over the long term. Until now, there is considerably less literature dedicated to membrane ageing than to cleaning/disinfection. The knowledge in cleaning/disinfection efficiency has recently been improved. But in order to develop optimized cleaning/disinfection protocols there still remains a challenge to better understand membrane ageing. In order to compensate for the lack of correlated cleaning/disinfection and ageing data from the literature, this paper investigates cleaning/disinfection efficiencies and ageing damages of organic ultrafiltration membranes. The final aim is to provide less detrimental cleaning/disinfection procedures and to propose some guidelines which should have been taken into consideration in term of membrane ageing studies. To carry out this study, this article will detail the background of cleaning/disinfection and aging membrane topics in a first introductive part. In a second part, key factors and endpoints of cleaning/disinfection and aging membranes will be discussed deeply: the membrane role and the cleaning parameters roles, such as water quality, storing conditions, cleaning/disinfection/aging agents/conditions/protocols. The third and last part will be developed the parameters, methods and ways of characterization at our disposal and commonly used to develop and implement membrane cleaning and/or ageing studies. Copyright © 2014 Elsevier Ltd. All rights reserved.

  11. An Intervention to Reduce Residential Insecticide Exposure during Pregnancy among an Inner-City Cohort

    PubMed Central

    Williams, Megan K.; Barr, Dana B.; Camann, David E.; Cruz, Linda A.; Carlton, Elizabeth J.; Borjas, Mejico; Reyes, Andria; Evans, Dave; Kinney, Patrick L.; Whitehead, Ralph D.; Perera, Frederica P.; Matsoanne, Stephen; Whyatt, Robin M.

    2006-01-01

    Background We previously reported widespread insecticide exposure during pregnancy among inner-city women from New York City. Here we report on a pilot intervention using integrated pest management (IPM) to reduce pest infestations and residential insecticide exposures among pregnant New York City African-American and Latina women (25 intervention and 27 control homes). Methods The IPM consisted of professional cleaning, sealing of pest entry points, application of low-toxicity pesticides, and education. Cockroach infestation levels and 2-week integrated indoor air samples were collected at baseline and one month postintervention. The insecticides detected in the indoor air samples were also measured in maternal and umbilical cord blood collected at delivery. Results Cockroach infestations decreased significantly (p = 0.016) after the intervention among intervention cases but not control households. Among the intervention group, levels of piperonyl butoxide (a pyrethroid synergist) were significantly lower in indoor air samples after the intervention (p = 0.016). Insecticides were detected in maternal blood samples collected at delivery from controls but not from the intervention group. The difference was significant for trans-permethrin (p = 0.008) and of borderline significance (p = 0.1) for cis-permethrin and 2-isopropoxyphenol (a propoxur metabolite). Conclusion To our knowledge, this is the first study to use biologic dosimeters of prenatal pesticide exposure for assessing effectiveness of IPM. These pilot data suggest that IPM is an effective strategy for reducing pest infestation levels and the internal dose of insecticides during pregnancy. PMID:17107853

  12. Bacterial contamination of stethoscope chest pieces and the effect of daily cleaning.

    PubMed

    Fujita, H; Hansen, B; Hanel, R

    2013-01-01

    Stethoscopes are a potential source of nosocomial infection for hospitalized humans, a phenomenon not previously studied in companion animals. To determine if daily cleaning of stethoscope chest pieces reduces bacterial contamination between cleanings. Client-owned dogs and cats. Prospective observational study. In phase 1, bacterial cultures were obtained from the chest pieces of 10 participant stethoscopes once weekly for 3 weeks. In phase 2, stethoscopes were cleaned daily and 2 culture samples were obtained once weekly, immediately before and after cleaning with 70% isopropyl alcohol, for 3 weeks. Daily cleaning eliminated bacteria immediately after each cleaning (P = .004), but did not reduce the rate of positive cultures obtained before cleaning in phase 2. Cultures were positive for 20/30 (67%) samples during phase 1 and 18/30 (60%) obtained before daily cleaning during phase 2. Recovered organisms included normal skin flora, agents of opportunistic infections, and potential pathogens. The only genus that was repeatedly recovered from the same stethoscope for 2 or more consecutive weeks was Bacillus sp. Daily cleaning was highly effective at removing bacteria, but provided no reduction in precleaning contamination. Cleaning stethoscopes after use on dogs or cats infected with pathogenic bacteria and before use on immunocompromised animals should be considered. Copyright © 2013 by the American College of Veterinary Internal Medicine.

  13. Efficacy of detergent and water versus bleach for disinfection of direct contact ophthalmic lenses.

    PubMed

    Abbey, Ashkan M; Gregori, Ninel Z; Surapaneni, Krishna; Miller, Darlene

    2014-06-01

    Although manufacturers recommend cleaning ophthalmic lenses with detergent and water and then with a specific disinfectant, disinfectants are rarely used in ophthalmic practices. The aim of this pilot study was to evaluate the efficacy of detergent and water versus that of bleach, a recommended disinfectant, to eliminate common ocular bacteria and viruses from ophthalmic lenses. Three bacterial strains (Staphylococcus epidermidis, Corynebacterium straitum, and methicillin-resistant Staphylococcus aureus and 2 viral strains (adenovirus and herpes simplex virus [HSV] type-1) were individually inoculated onto 20 gonioscopy and laser lenses. The lenses were washed with detergent and water and then disinfected with 10% bleach. All the lenses were cultured after inoculation, after washing with detergent and water, and after disinfecting with the bleach. Bacterial cultures in thioglycollate broth were observed for 3 weeks, and viral cultures were observed for 2 weeks. The presence of viruses was also detected by multiplex polymerase chain reaction (PCR). All 20 lenses inoculated with S. epidermidis, C. straitum, adenovirus, and HSV-1 showed growth after inoculation but no growth after washing with detergent/water and after disinfecting with the bleach. All lenses showed positive HSV and adenovirus PCR results after inoculation and negative PCR results after washing with detergent/water and after disinfecting with bleach. All methicillin-resistant S. aureus-contaminated lenses showed growth after inoculation and no growth after washing with detergent and water. However, 1 lens showed positive growth after disinfecting with bleach. Cleaning with detergent and water seemed to effectively eliminate bacteria and viruses from the surface of contaminated ophthalmic lenses. Further studies are warranted to design practical disinfection protocols that minimize lens damage.

  14. Waste Isolation Pilot Plant Salt Decontamination Testing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Demmer, Ricky Lynn; Reese, Stephen Joseph

    2015-03-01

    On February 14, 2014, americium and plutonium contamination was released in the Waste Isolation Pilot Plant (WIPP) salt caverns. Several practical, easily deployable methods of decontaminating WIPP salt, using a surrogate contaminant and americium (241Am), were developed and tested. The effectiveness of the methods is evaluated qualitatively, and to the extent practical, quantitatively. Of the methods tested (dry brushing, vacuum cleaning, water washing, mechanical grinding, strippable coatings, and fixative barriers), the most practical seems to be water washing. Effectiveness is very high, and water washing is easy and rapid to deploy. The amount of wastewater produced (~2 L/m2) would bemore » substantial and may not be easy to manage, but the method is the clear winner from a usability perspective. Removable surface contamination levels (smear results) from water washed coupons found no residual removable contamination. Thus, whatever contamination is left is likely adhered to (or trapped within) the salt. The other option that shows promise is the use of a fixative barrier. Bartlett Nuclear, Inc.’s Polymeric Barrier System proved the most durable of the coatings tested. The coatings were not tested for contaminant entrapment, only for coating integrity and durability.« less

  15. A comparison of the effects of toothbrushing and handpiece prophylaxis on retention of sealants.

    PubMed

    Kolavic Gray, Shellie; Griffin, Susan O; Malvitz, Dolores M; Gooch, Barbara F

    2009-01-01

    Tooth surface cleaning before acid etching is considered to be an important step in the retention of resin-based pit-and-fissure sealants. The authors reviewed and summarized instructions for cleaning tooth surfaces from five manufacturers of 10 unfilled resin-based sealants marketed in the United States. The authors also searched electronic databases for studies that directly compared the effects of different surface-cleaning methods on sealant retention and for systematic reviews of the effectiveness of sealants. They explored the association between surface-cleaning methods and sealant retention in the studies included in the systematic reviews. They calculated the summary weighted retention rates for studies that used either a handpiece or toothbrush prophylaxis. All of the sealant manufacturers' instructions for use (IFU) recommended cleaning the tooth before acid etching. None of the IFU directly stated that a handpiece was required to perform the cleaning, but five IFU implied the use of handpiece prophylaxis. None of the IFU recommended surface-altering procedures in caries-free teeth. Direct evidence from two clinical trials showed no difference in complete sealant retention between surfaces cleaned mechanically with pumice or prophylaxis paste and those cleaned with air-water syringe or dry toothbrushing. Indirect evidence from 10 studies found that weighted summary retention by year after sealant placement in studies that used toothbrush prophylaxis was greater than or equivalent to values for studies that used handpiece prophylaxis. Levels of sealant retention after surface cleaning with toothbrush prophylaxis were at least as high as those associated with hand-piece prophylaxis. This finding may translate into lower resource costs for sealant placement.

  16. Benefaction studies on the Hasan Celebi magnetite deposit, Turkey

    USGS Publications Warehouse

    Pressler, Jean W.; Akar, Ali

    1972-01-01

    Bench-scale and semicontinuous tests were performed on surface, trench, and diamond drill core samples from the Hasan Celebi low-grade magnetite deposit to determine the optimum benefication procedures utilizing wet magnetic separation techniques. Composite core samples typically contain about 27 percent recoverable magnetite and require crushing and grinding through 1 mm in size to insure satisfactory separation of the gangue from the magnetite. Regrinding and cleaning the magnetite concentrate to 80 percent minus 150-mesh is necessary to obtain an optimum of 66 percent iron. Semicontinuous pilot-plant testing with the wet magnetic drum using the recycled middling technique indicates that as much as 83 percent of the acid-soluble iron can be recovered into a concentrate containing 66 percent iron, with minimum deleterious elements. This represents 27 weight percent of the original ore. Further tests will continue when the Maden Tetkik ve Arama Enstitusu (MTA) receives 24 tons of bulk sample from an exploratory drift and cross-cut now being driven through a section of the major reserve area.

  17. Inspections of hand washing supplies and hand sanitizer in public schools.

    PubMed

    Ramos, Mary M; Blea, Mary; Trujillo, Rebecca; Greenberg, Cynthia

    2010-10-01

    Hand washing and hand antisepsis are proven infection control measures in the school setting, yet barriers such as lack of soap, paper towels, and hand sanitizer can hinder compliance. This pilot study measured the prevalence of hand cleaning supplies in public schools. Ten school districts (93 schools) participated in school nurse inspections. In November 2008, 90 schools (97%) reported their inspection results. Among 697 total bathrooms, 88.8% had soap and 91.7% had paper towels or hand dryers. Hand sanitizer was reported in 1.2% of bathrooms and 15.2% of cafeterias. No difference was observed between boys' and girls' bathrooms, or primary and secondary schools, in the prevalence of soap or paper towels/hand dryers. Hand washing supplies were generally available in public school bathrooms. Alcohol-based hand sanitizer in school bathrooms was reported occasionally and should be discouraged. Hand sanitizer in a supervised setting, the school cafeteria, was not often reported and should be promoted.

  18. Graphene nanoribbons epitaxy on boron nitride

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lu, Xiaobo; Wang, Shuopei; Wu, Shuang

    2016-03-14

    In this letter, we report a pilot study on epitaxy of monolayer graphene nanoribbons (GNRs) on hexagonal boron nitride (h-BN). We found that GNRs grow preferentially from the atomic steps of h-BN, forming in-plane heterostructures. GNRs with well-defined widths ranging from ∼15 nm to ∼150 nm can be obtained reliably. As-grown GNRs on h-BN have high quality with a carrier mobility of ∼20 000 cm{sup 2} V{sup −1} s{sup −1} for ∼100-nm-wide GNRs at a temperature of 1.7 K. Besides, a moiré pattern induced quasi-one-dimensional superlattice with a periodicity of ∼15 nm for GNR/h-BN was also observed, indicating zero crystallographic twisting angle between GNRs and h-BNmore » substrate. The superlattice induced band structure modification is confirmed by our transport results. These epitaxial GNRs/h-BN with clean surfaces/interfaces and tailored widths provide an ideal platform for high-performance GNR devices.« less

  19. Measuring quality indicators in the operating room: cleaning and turnover time.

    PubMed

    Jericó, Marli de Carvalho; Perroca, Márcia Galan; da Penha, Vivian Colombo

    2011-01-01

    This exploratory-descriptive study was carried out in the Surgical Center Unit of a university hospital aiming to measure time spent with concurrent cleaning performed by the cleaning service and turnover time and also investigated potential associations between cleaning time and the surgery's magnitude and specialty, period of the day and the room's size. The sample consisted of 101 surgeries, computing cleaning time and 60 surgeries, computing turnover time. The Kaplan-Meier method was used to analyze time and Pearson's correlation to study potential correlations. The time spent in concurrent cleaning was 7.1 minutes and turnover time was 35.6 minutes. No association between cleaning time and the other variables was found. These findings can support nurses in the efficient use of resources thereby speeding up the work process in the operating room.

  20. Synergetic effect of chelating agent and nonionic surfactant for benzotriazole removal on post Cu-CMP cleaning

    NASA Astrophysics Data System (ADS)

    Yanlei, Li; Yuling, Liu; Chenwei, Wang; Yue, Li

    2016-08-01

    The cleaning of copper interconnects after chemical mechanical planarization (CMP) process is a critical step in integrated circuits (ICs) fabrication. Benzotriazole (BTA), which is used as corrosion inhibitor in the copper CMP slurry, is the primary source for the formation of organic contaminants. The presence of BTA can degrade the electrical properties and reliability of ICs which needs to be removed by using an effective cleaning solution. In this paper, an alkaline cleaning solution was proposed. The alkaline cleaning solution studied in this work consists of a chelating agent and a nonionic surfactant. The removal of BTA was characterized by contact angle measurements and potentiodynamic polarization studies. The cleaning properties of the proposed cleaning solution on a 300 mm copper patterned wafer were also quantified, total defect counts after cleaning was studied, scanning electron microscopy (SEM) review was used to identify types of BTA to confirm the ability of cleaning solution for BTA removal. All the results reveal that the chelating agent can effectively remove the BTA residual, nonionic surfactant can further improve the performance. Project supported by the Natural Science Foundation of Hebei Province, China (No. F2015202267) and the Scientific Innovation Grant for Excellent Young Scientists of Hebei University of Technology (No. 2015007).

  1. Validation of adenosine triphosphate to audit manual cleaning of flexible endoscope channels.

    PubMed

    Alfa, Michelle J; Fatima, Iram; Olson, Nancy

    2013-03-01

    Compliance with cleaning of flexible endoscope channels cannot be verified using visual inspection. Adenosine triphosphate (ATP) has been suggested as a possible rapid cleaning monitor for flexible endoscope channels. There have not been published validation studies to specify the level of ATP that indicates inadequate cleaning has been achieved. The objective of this study was to validate the Clean-Trace (3M Inc, St. Paul, MN) ATP water test method for monitoring manual cleaning of flexible endoscopes. This was a simulated use study using a duodenoscope as the test device. Artificial test soil containing 10(6) colony-forming units of Pseudomonas aeruginosa and Enterococcus faecalis was used to perfuse all channels. The flush sample method for the suction-biopsy (L1) or air-water channel (L2) using 40 and 20 mLs sterile reverse osmosis water, respectively, was validated. Residuals of ATP, protein, hemoglobin, and bioburden were quantitated from channel samples taken from uncleaned, partially cleaned, and fully cleaned duodenoscopes. The benchmarks for clean were as follows: <6.4 μg/cm(2) protein, <2.2 μg/cm(2) hemoglobin, and <4-log10 colony-forming units/cm(2) bioburden. The average ATP in clean channel samples was 27.7 RLUs and 154 RLUs for L1 and L2, respectively (<200 RLUs for all channels). The average protein, hemoglobin, and bioburden benchmarks were achieved if <200 RLUs were detected. If the channel sample was >200 RLUs, the residual organic and bioburden levels would exceed the acceptable benchmarks. Our data validated that flexible endoscopes that have complete manual cleaning will have <200 RLUs by the Clean-Trace ATP test. Copyright © 2013 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Mosby, Inc. All rights reserved.

  2. Asbestos-fiber reentrainment during dry vacuuming and wet cleaning of asbestos-contaminated carpet. Report for January 1988-July 1989

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kominsky, J.R.; Freyberg, R.W.

    A study was conducted to evaluate the potential for asbestos fiber reentrainment during cleaning of carpet contaminated with asbestos. Two types of carpet cleaning equipment were evaluated at two carpet contamination levels. Airborne asbestos concentrations were determined before and during carpet cleaning. Overall, airborne asbestos concentrations were two to four times greater during the carpet cleaning activity. The level of asbestos contamination and the type of cleaning method used had no statistically significant effect on the relative increase of airborne asbestos concentrations during carpet cleaning.

  3. Testing neoclassical competitive market theory in the field.

    PubMed

    List, John A

    2002-11-26

    This study presents results from a pilot field experiment that tests predictions of competitive market theory. A major advantage of this particular field experimental design is that my laboratory is the marketplace: subjects are engaged in buying, selling, and trading activities whether I run an exchange experiment or am a passive observer. In this sense, I am gathering data in a natural environment while still maintaining the necessary control to execute a clean comparison between treatments. The main results of the study fall into two categories. First, the competitive model predicts reasonably well in some market treatments: the expected price and quantity levels are approximated in many market rounds. Second, the data suggest that market composition is important: buyer and seller experience levels impact not only the distribution of rents but also the overall level of rents captured. An unexpected result in this regard is that average market efficiency is lowest in markets that match experienced buyers and experienced sellers and highest when experienced buyers engage in bargaining with inexperienced sellers. Together, these results suggest that both market experience and market composition play an important role in the equilibrium discovery process.

  4. Evaluation of Commonly Used Products for Disinfecting Clipper Blades in Veterinary Practices: A Pilot Study.

    PubMed

    Ley, Benjamin; Silverman, Edward; Peery, Kara; Dominguez, Delfina

    2016-01-01

    Nosocomial infections are a concern of growing interest in veterinary medicine. Clipper blades have been confirmed as fomites for numerous potential pathogens and, as such, may be associated with wound and surgical site infections. The goal of this study was to evaluate the disinfectant capabilities of several commonly used clipper blade cleaning products. Seventy sterile clipper blades were inoculated with strains of Pseudomonas aeruginosa , Escherichia coli , and Staphylococcus aureus . Blades were then subjected to one of seven treatment groups for disinfecting. Quantitative cultures of remaining bacteria were performed. All blades in the control group showed large amounts of bacterial recovery. Culture results showed no recovery in blades soaked in alcohol or chlorhexidine or those sprayed with an ethanol/o-phenylphenol product, while moderate recovery was seen with all other treatments. These results show that persistent contamination of clipper blades can occur with the use of several commonly used disinfectant products. Further research is necessary to evaluate fungicidal capabilities as well as the effect of disinfection on clipper blade maintenance.

  5. Valid screening questions useful to diagnose hand and forearm eczema are available in the Spanish language, a new tool for global research.

    PubMed

    Martí-Margarit, Anna; Manresa, Josep M; Herdman, Mike; Pujol, Ramon; Serra, Consol; Flyvholm, Mary-Ann; Giménez-Arnau, Ana M

    2015-04-01

    Hand eczema is an impacting cutaneous disease. Globally valid tools that help to diagnose hand and forearm eczema are required. To validate the questions to detect hand and/or forearm eczema included in the "Nordic Occupational Skin Questionnaire" (NOSQ-2002) in the Spanish language. A prospective pilot study was conducted with 80 employees of a cleaning company and a retrospective one involving 2,546 individuals. The responses were analysed for sensitivity, specificity and positive and negative predictive values. The final diagnosis according to the patients' hospital records, the specialty care records and the physical examination was taken as gold standard. The Dermatology Life Quality Index (DLQI) was also evaluated. Sensitivity and specificity, in a worst case scenario (WC) combining both questions, were 96.5% and 66.7%, respectively, and in a per protocol (PP) analysis, were 96.5% and 75.2%. The questions validated detected eczema effectively, making this tool suitable for use e.g. in multicentre epidemiological studies or clinical trials.

  6. EVALUATION OF TWO CLEANING METHODS FOR THE REMOVAL OF ASBESTOS FIBERS FROM CARPET

    EPA Science Inventory

    This research study examined the effectiveness of dry vacuuming and wet cleaning for the removal of asbestos fibers from carpet, and evaluated the potential for fiber reentrainment during carpet cleaning activities. outine carpet cleaning operations using high-efficiency particul...

  7. Evaluation of Various Cleaning Methods to Remove Bacillus Spores from Spacecraft Hardware Materials

    NASA Technical Reports Server (NTRS)

    Venkateswaran, Kasthuri; Chung, Shirley; Allton, Judith; Kern, Roger

    2004-01-01

    A detailed study was made of the biological cleaning effectiveness, defined in terms of the ability to remove bacterial spores, of a number of methods used to clean hardware surfaces. Aluminum (Al 6061) and titanium (Ti 6Al-4V) were chosen for the study as they were deemed the two materials most likely to be used in spacecraft extraterrestrial sampler construction. None of the cleaning protocols tested completely removed viable spores from the surface of the aluminum. In contrast, titanium was capable of being cleaned to sterility by two methods, the JPL standard and the commercial SAMS cleaning process. Further investigation showed that the passivation step employed in the JPL standard method is an effective surface sterilant on both metals but not compatible with aluminum. It is recommended that titanium (Ti 6Al-4V) be considered superior to aluminum (Al 6061) for use in spacecraft sampling hardware, both for its potential to be cleaned to sterilization and for its ability to withstand the most effective cleaning protocols.

  8. Evaluating the use of laser radiation in cleaning of copper embroidery threads on archaeological Egyptian textiles

    NASA Astrophysics Data System (ADS)

    Abdel-Kareem, Omar; Harith, M. A.

    2008-07-01

    Cleaning of copper embroidery threads on archaeological textiles is still a complicated conservation process, as most textile conservators believe that the advantages of using traditional cleaning techniques are less than their disadvantages. In this study, the uses of laser cleaning method and two modified recipes of wet cleaning methods were evaluated for cleaning of the corroded archaeological Egyptian copper embroidery threads on an archaeological Egyptian textile fabric. Some corroded copper thread samples were cleaned using modified recipes of wet cleaning method; other corroded copper thread samples were cleaned with Q-switched Nd:YAG laser radiation of wavelength 532 nm. All tested metal thread samples before and after cleaning were investigated using a light microscope and a scanning electron microscope with an energy dispersive X-ray analysis unit. Also the laser-induced breakdown spectroscopy (LIBS) technique was used for the elemental analysis of laser-cleaned samples to follow up the laser cleaning procedure. The results show that laser cleaning is the most effective method among all tested methods in the cleaning of corroded copper threads. It can be used safely in removing the corrosion products without any damage to both metal strips and fibrous core. The tested laser cleaning technique has solved the problems caused by other traditional cleaning techniques that are commonly used in the cleaning of metal threads on museum textiles.

  9. Bioreactor and process design for biohydrogen production.

    PubMed

    Show, Kuan-Yeow; Lee, Duu-Jong; Chang, Jo-Shu

    2011-09-01

    Biohydrogen is regarded as an attractive future clean energy carrier due to its high energy content and environmental-friendly conversion. It has the potential for renewable biofuel to replace current hydrogen production which rely heavily on fossil fuels. While biohydrogen production is still in the early stage of development, there have been a variety of laboratory- and pilot-scale systems developed with promising potential. This work presents a review of advances in bioreactor and bioprocess design for biohydrogen production. The state-of-the art of biohydrogen production is discussed emphasizing on production pathways, factors affecting biohydrogen production, as well as bioreactor configuration and operation. Challenges and prospects of biohydrogen production are also outlined. Copyright © 2011 Elsevier Ltd. All rights reserved.

  10. Stethoscope Hygiene: Practice and Attitude of Medical Students.

    PubMed

    Gazibara, Tatjana; Radovanovic, Sanja; Maric, Gorica; Rancic, Biljana; Kisic-Tepavcevic, Darija; Pekmezovic, Tatjana

    2015-01-01

    The purpose of this study was to evaluate the frequency and attitude of medical students towards cleaning their stethoscopes. A cross-sectional study was carried out in the first week of December 2013. The study included 771 students (397 in their fourth and 374 in their sixth year) from the Faculty of Medicine, University of Belgrade, Serbia. An anonymous questionnaire was distributed to students before the start of compulsory lessons in classrooms. 317 of the 397 fourth-year students (79.8%) and 306 of the 374 sixth-year students (81.9%) cleaned their stethoscope. The stethoscope diaphragm was most commonly cleaned, while the flexible tubing was the least commonly cleaned area, mainly using ethyl alcohol-based agents. The strongest positive attitude was observed for the statement 'It is important that my stethoscope is clean' (4.3 out of 5.0). A positive correlation (Spearman's x03C1; = 0.105) was observed between a higher frequency of cleaning and the stronger positive notion that a stethoscope should be cleaned. A considerably high proportion of the students studied had ever cleaned their stethoscopes. Based on the students' responses, it would be useful to implement instructions on stethoscope hygiene in the regular practical curriculum with the aim of applying stethoscope disinfection in daily work. © 2015 S. Karger AG, Basel.

  11. Cleaning at Home and at Work in Relation to Lung Function Decline and Airway Obstruction.

    PubMed

    Svanes, Øistein; Bertelsen, Randi J; Lygre, Stein H L; Carsin, Anne E; Antó, Josep M; Forsberg, Bertil; García-García, José M; Gullón, José A; Heinrich, Joachim; Holm, Mathias; Kogevinas, Manolis; Urrutia, Isabel; Leynaert, Bénédicte; Moratalla, Jesús M; Le Moual, Nicole; Lytras, Theodore; Norbäck, Dan; Nowak, Dennis; Olivieri, Mario; Pin, Isabelle; Probst-Hensch, Nicole; Schlünssen, Vivi; Sigsgaard, Torben; Skorge, Trude D; Villani, Simona; Jarvis, Debbie; Zock, Jan P; Svanes, Cecilie

    2018-05-01

    Cleaning tasks may imply exposure to chemical agents with potential harmful effects to the respiratory system, and increased risk of asthma and respiratory symptoms among professional cleaners and in persons cleaning at home has been reported. Long-term consequences of cleaning agents on respiratory health are, however, not well described. This study aimed to investigate long-term effects of occupational cleaning and cleaning at home on lung function decline and airway obstruction. The European Community Respiratory Health Survey (ECRHS) investigated a multicenter population-based cohort at three time points over 20 years. A total of 6,235 participants with at least one lung function measurement from 22 study centers, who in ECRHS II responded to questionnaire modules concerning cleaning activities between ECRHS I and ECRHS II, were included. The data were analyzed with mixed linear models adjusting for potential confounders. As compared with women not engaged in cleaning (ΔFEV 1  = -18.5 ml/yr), FEV 1 declined more rapidly in women responsible for cleaning at home (-22.1; P = 0.01) and occupational cleaners (-22.4; P = 0.03). The same was found for decline in FVC (ΔFVC = -8.8 ml/yr; -13.1, P = 0.02; and -15.9, P = 0.002; respectively). Both cleaning sprays and other cleaning agents were associated with accelerated FEV 1 decline (-22.0, P = 0.04; and -22.9, P = 0.004; respectively). Cleaning was not significantly associated with lung function decline in men or with FEV 1 /FVC decline or airway obstruction. Women cleaning at home or working as occupational cleaners had accelerated decline in lung function, suggesting that exposures related to cleaning activities may constitute a risk to long-term respiratory health.

  12. Correlating Cleaning Thoroughness with Effectiveness and Briefly Intervening to Affect Cleaning Outcomes: How Clean Is Cleaned?

    PubMed Central

    Hosford, Eve; Ong, Ana; Richesson, Douglas; Fraser, Susan; Kwak, Yoon; Miller, Sonia; Julius, Michael; McGann, Patrick; Lesho, Emil

    2016-01-01

    Objectives The most efficient approach to monitoring and improving cleaning outcomes remains unresolved. We sought to extend the findings of a previous study by determining whether cleaning thoroughness (dye removal) correlates with cleaning efficacy (absence of molecular or cultivable biomaterial) and whether one brief educational intervention improves cleaning outcomes. Design Before-after trial. Setting Newly built community hospital. Intervention 90 minute training refresher with surface-specific performance results. Methods Dye removal, measured by fluorescence, and biomaterial removal and acquisition, measured with culture and culture-independent PCR-based assays, were clandestinely assessed for eight consecutive months. At this midpoint, results were presented to the cleaning staff (intervention) and assessments continued for another eight consecutive months. Results 1273 surfaces were sampled before and after terminal room cleaning. In the short-term, dye removal increased from 40.3% to 50.0% (not significant). For the entire study period, dye removal also improved but not significantly. After the intervention, the number of rooms testing positive for specific pathogenic species by culturing decreased from 55.6% to 36.6% (not significant), and those testing positive by PCR fell from 80.6% to 53.7% (P = 0.016). For nonspecific biomaterial on surfaces: a) removal of cultivable Gram-negatives (GN) trended toward improvement (P = 0.056); b) removal of any cultivable growth was unchanged but acquisition (detection of biomaterial on post-cleaned surfaces that were contaminant-free before cleaning) worsened (P = 0.017); c) removal of PCR-based detection of bacterial DNA improved (P = 0.046), but acquisition worsened (P = 0.003); d) cleaning thoroughness and efficacy were not correlated. Conclusion At this facility, a minor intervention or minimally more aggressive cleaning may reduce pathogen-specific contamination, but not without unintended consequences. PMID:27196635

  13. Correlating Cleaning Thoroughness with Effectiveness and Briefly Intervening to Affect Cleaning Outcomes: How Clean Is Cleaned?

    PubMed

    Clifford, Robert; Sparks, Michael; Hosford, Eve; Ong, Ana; Richesson, Douglas; Fraser, Susan; Kwak, Yoon; Miller, Sonia; Julius, Michael; McGann, Patrick; Lesho, Emil

    2016-01-01

    The most efficient approach to monitoring and improving cleaning outcomes remains unresolved. We sought to extend the findings of a previous study by determining whether cleaning thoroughness (dye removal) correlates with cleaning efficacy (absence of molecular or cultivable biomaterial) and whether one brief educational intervention improves cleaning outcomes. Before-after trial. Newly built community hospital. 90 minute training refresher with surface-specific performance results. Dye removal, measured by fluorescence, and biomaterial removal and acquisition, measured with culture and culture-independent PCR-based assays, were clandestinely assessed for eight consecutive months. At this midpoint, results were presented to the cleaning staff (intervention) and assessments continued for another eight consecutive months. 1273 surfaces were sampled before and after terminal room cleaning. In the short-term, dye removal increased from 40.3% to 50.0% (not significant). For the entire study period, dye removal also improved but not significantly. After the intervention, the number of rooms testing positive for specific pathogenic species by culturing decreased from 55.6% to 36.6% (not significant), and those testing positive by PCR fell from 80.6% to 53.7% (P = 0.016). For nonspecific biomaterial on surfaces: a) removal of cultivable Gram-negatives (GN) trended toward improvement (P = 0.056); b) removal of any cultivable growth was unchanged but acquisition (detection of biomaterial on post-cleaned surfaces that were contaminant-free before cleaning) worsened (P = 0.017); c) removal of PCR-based detection of bacterial DNA improved (P = 0.046), but acquisition worsened (P = 0.003); d) cleaning thoroughness and efficacy were not correlated. At this facility, a minor intervention or minimally more aggressive cleaning may reduce pathogen-specific contamination, but not without unintended consequences.

  14. Rudimentary Cleaning Compared to Level 300A

    NASA Technical Reports Server (NTRS)

    Arpin, Christina Y. Pina; Stoltzfus, Joel

    2012-01-01

    A study was done to characterize the cleanliness level achievable when using a rudimentary cleaning process, and results were compared to JPR 5322.1G Level 300A. While it is not ideal to clean in a shop environment, some situations (e.g., field combat operations) require oxygen system hardware to be maintained and cleaned to prevent a fire hazard, even though it cannot be sent back to a precision cleaning facility. This study measured the effectiveness of basic shop cleaning. Initially, three items representing parts of an oxygen system were contaminated: a metal plate, valve body, and metal oxygen bottle. The contaminants chosen were those most likely to be introduced to the system during normal use: oil, lubricant, metal shavings/powder, sand, fingerprints, tape, lip balm, and hand lotion. The cleaning process used hot water, soap, various brushes, gaseous nitrogen, water nozzle, plastic trays, scouring pads, and a controlled shop environment. Test subjects were classified into three groups: technical professionals having an appreciation for oxygen hazards; professional precision cleaners; and a group with no previous professional knowledge of oxygen or precision cleaning. Three test subjects were in each group, and each was provided with standard cleaning equipment, a cleaning procedure, and one of each of the three test items to clean. The results indicated that the achievable cleanliness level was independent of the technical knowledge or proficiency of the personnel cleaning the items. Results also showed that achieving a Level 300 particle count was more difficult than achieving a Level A nonvolatile residue amount.

  15. Researching effective approaches to cleaning in hospitals: protocol of the REACH study, a multi-site stepped-wedge randomised trial.

    PubMed

    Hall, Lisa; Farrington, Alison; Mitchell, Brett G; Barnett, Adrian G; Halton, Kate; Allen, Michelle; Page, Katie; Gardner, Anne; Havers, Sally; Bailey, Emily; Dancer, Stephanie J; Riley, Thomas V; Gericke, Christian A; Paterson, David L; Graves, Nicholas

    2016-03-24

    The Researching Effective Approaches to Cleaning in Hospitals (REACH) study will generate evidence about the effectiveness and cost-effectiveness of a novel cleaning initiative that aims to improve the environmental cleanliness of hospitals. The initiative is an environmental cleaning bundle, with five interdependent, evidence-based components (training, technique, product, audit and communication) implemented with environmental services staff to enhance hospital cleaning practices. The REACH study will use a stepped-wedge randomised controlled design to test the study intervention, an environmental cleaning bundle, in 11 Australian hospitals. All trial hospitals will receive the intervention and act as their own control, with analysis undertaken of the change within each hospital based on data collected in the control and intervention periods. Each site will be randomised to one of the 11 intervention timings with staggered commencement dates in 2016 and an intervention period between 20 and 50 weeks. All sites complete the trial at the same time in 2017. The inclusion criteria allow for a purposive sample of both public and private hospitals that have higher-risk patient populations for healthcare-associated infections (HAIs). The primary outcome (objective one) is the monthly number of Staphylococcus aureus bacteraemias (SABs), Clostridium difficile infections (CDIs) and vancomycin resistant enterococci (VRE) infections, per 10,000 bed days. Secondary outcomes for objective one include the thoroughness of hospital cleaning assessed using fluorescent marker technology, the bio-burden of frequent touch surfaces post cleaning and changes in staff knowledge and attitudes about environmental cleaning. A cost-effectiveness analysis will determine the second key outcome (objective two): the incremental cost-effectiveness ratio from implementation of the cleaning bundle. The study uses the integrated Promoting Action on Research Implementation in Health Services (iPARIHS) framework to support the tailored implementation of the environmental cleaning bundle in each hospital. Evidence from the REACH trial will contribute to future policy and practice guidelines about hospital environmental cleaning. It will be used by healthcare leaders and clinicians to inform decision-making and implementation of best-practice infection prevention strategies to reduce HAIs in hospitals. Australia New Zealand Clinical Trial Registry ACTRN12615000325505.

  16. Occupational risk factors for hand dermatitis among professional cleaners in Spain

    PubMed Central

    Mirabelli, Maria C.; Vizcaya, David; Margarit, Anna Martí; Antó, Josep Maria; Arjona, Lourdes; Barreiro, Esther; Orriols, Ramon; Gimenez-Arnau, Ana; Zock, Jan-Paul

    2012-01-01

    Summary Background Dermatitis is an important health outcome for workers whose jobs put them in contact with irritants or sensitizing agents. Objectives We conducted analysis of data from the Epidemiological Study on the Risk of Asthma in Cleaning Workers 2 (EPIASLI2) study to assess worksites and cleaning products as risk factors for hand dermatitis among professional cleaning workers. Materials/Methods We distributed 4 993 questionnaires to employees of 37 cleaning companies and used data from 818 (16%) respondents who provided information about skin symptoms and cleaning-related exposures. We assessed associations between the frequencies of worksite and cleaning product exposures and a symptom-based definition of hand dermatitis among current cleaning workers (n=693) and a comparison population (n=125). Results Hand dermatitis was reported by 28% of current cleaning workers, versus 18% of the comparison population, and was associated with cleaning outdoor areas and schools, and the use of hydrochloric acid (prevalence ratio [PR]: 1.92, 95% confidence interval [CI]: 1.22, 3.02) and dust mop products (PR: 1.75, 95% CI: 1.11, 2.75). Conclusions Professional cleaning workers may not be sufficiently protected from cutaneous disease at work. Future research should further investigate the roles of multiple product exposures and personal protective equipment. PMID:22268785

  17. Global public health impact of recovered supplies from operating rooms: a critical analysis with national implications.

    PubMed

    Wan, Eric L; Xie, Li; Barrett, Miceile; Baltodano, Pablo A; Rivadeneira, Andres F; Noboa, Jonathan; Silver, Maya; Zhou, Richard; Cho, Suzy; Tam, Tammie; Yurter, Alp; Gentry, Carol; Palacios, Jorge; Rosson, Gedge D; Redett, Richard J

    2015-01-01

    In modern operating rooms, clean and unused medical supplies are routinely discarded and can be effectively recovered and redistributed abroad to alleviate the environmental burden of donor hospitals and to generate substantial health benefits at resource-poor recipient institutions. We established a recovery and donation program to collect clean and unused supplies for healthcare institutions in developing nations. We analyzed items donated over a 3-year period (September 2010-November 2013) by quantity and weight, and estimated the projected value of the program under potential nationwide participation. To capture the health benefits attributable to the donated supplies at recipient institutions, we partnered with two tertiary-care centers in Guayaquil, Ecuador and conducted a pilot study on the utility of the donated supplies at the recipient institutions (October 2013). We determined the disability-adjusted life years (DALY) averted for all patients undergoing procedures involving donated items and estimated the annual attributable DALY as well as the cost per DALY averted both by supply and by procedure. Approximately, 2 million lbs (907,185 kg) per year of medical supplies are recoverable from large non-rural US academic medical centers. Of these supplies, 19 common categories represent a potential for donation worth US $15 million per year, at a cost-utility of US $2.14 per DALY averted. Hospital operating rooms continue to represent a large source of recoverable surgical supplies that have demonstrable health benefits in the recipient communities. Cost-effective recovery and need-based donation programs can significantly alleviate the global burden of surgical diseases.

  18. Nanoparticle concentrations and composition in a dental office and dental laboratory: A pilot study on the influence of working procedures.

    PubMed

    Lang, Andreja; Ovsenik, Maja; Verdenik, Ivan; Remškar, Maja; Oblak, Čedomir

    2018-05-01

    During material treatment in dentistry particles of different size are released in the air. To examine the degree of particle exposure, air scanning to dental employees was performed by the Scanning Mobility Particle Sizer. The size, shape and chemical composition of particles collected with a low-pressure impactor were determined by scanning electronic microscopy and X-ray dispersive analysis. The average concentrations of nanoparticles during working periods in a clean dental laboratory (45,000-56,000 particles/cm 3 ), in an unclean dental laboratory (28,000-74,000 particles/cm 3 ), and in a dental office (21,000-50,000 particles/cm 3 ), were significantly higher compared to average concentrations during nonworking periods in the clean dental laboratory (11,000-24,000 particles/cm 3 ), unclean laboratory (14,000-40,000 particles/cm 3 ), and dental office (13,000-26,000 particles/cm 3 ). Peak concentration of nanoparticles in work-intensive periods were found significantly higher (up to 773,000 particles/cm 3 ), compared to the non-working periods (147,000 particles/cm 3 ) and work-less intensive periods (365,000 particles/cm 3 ). The highest mass concentration value ranged from 0.055-0.166 mg/m 3 . X-ray dispersive analysis confirmed the presence of carbon, potassium, oxygen, iron, aluminum, zinc, silicon, and phosphorus as integral elements of dental restorative materials in form of nanoparticle clusters, all smaller than 100 nm. We concluded that dental employees are exposed to nanoparticles in their working environment and are therefore potentially at risk for certain respiratory and systematic diseases.

  19. Three Case Studies in Green Cleaning

    ERIC Educational Resources Information Center

    State Education Standard, 2012

    2012-01-01

    This article presents case studies from three districts implementing green cleaning. In 2008, Missouri passed legislation requiring state education officials to convene a committee of stakeholders with the purpose of developing green cleaning guidelines and specifications for schools. The guide, published by the Department of Elementary and…

  20. Study and optimization of the ultrasound-enhanced cleaning of an ultrafiltration ceramic membrane through a combined experimental-statistical approach.

    PubMed

    Alventosa-deLara, E; Barredo-Damas, S; Alcaina-Miranda, M I; Iborra-Clar, M I

    2014-05-01

    Membrane fouling is one of the main drawbacks of ultrafiltration technology during the treatment of dye-containing effluents. Therefore, the optimization of the membrane cleaning procedure is essential to improve the overall efficiency. In this work, a study of the factors affecting the ultrasound-assisted cleaning of an ultrafiltration ceramic membrane fouled by dye particles was carried out. The effect of transmembrane pressure (0.5, 1.5, 2.5 bar), cross-flow velocity (1, 2, 3 ms(-1)), ultrasound power level (40%, 70%, 100%) and ultrasound frequency mode (37, 80 kHz and mixed wave) on the cleaning efficiency was evaluated. The lowest frequency showed better results, although the best cleaning performance was obtained using the mixed wave mode. A Box-Behnken Design was used to find the optimal conditions for the cleaning procedure through a response surface study. The optimal operating conditions leading to the maximum cleaning efficiency predicted (32.19%) were found to be 1.1 bar, 3 ms(-1) and 100% of power level. Finally, the optimized response was compared to the efficiency of a chemical cleaning with NaOH solution, with and without the use of ultrasound. By using NaOH, cleaning efficiency nearly triples, and it improves up to 25% by adding ultrasound. Copyright © 2013 Elsevier B.V. All rights reserved.

  1. Hazardous substances in frequently used professional cleaning products.

    PubMed

    Gerster, Fabian Melchior; Vernez, David; Wild, Pascal Pierre; Hopf, Nancy Brenna

    2014-01-01

    A growing number of studies have identified cleaners as a group at risk for adverse health effects of the skin and the respiratory tract. Chemical substances present in cleaning products could be responsible for these effects. Currently, only limited information is available about irritant and health hazardous chemical substances found in cleaning products. We hypothesized that chemical substances present in cleaning products are known health hazardous substances that might be involved in adverse health effects of the skin and the respiratory tract. We performed a systematic review of cleaning products used in the Swiss cleaning sector. We surveyed Swiss professional cleaning companies (n = 1476) to identify the most used products (n = 105) for inclusion. Safety data sheets (SDSs) were reviewed and hazardous substances present in cleaning products were tabulated with current European and global harmonized system hazard labels. Professional cleaning products are mixtures of substances (arithmetic mean 3.5 +/- 2.8), and more than 132 different chemical substances were identified in 105 products. The main groups of chemicals were fragrances, glycol ethers, surfactants, solvents; and to a lesser extent, phosphates, salts, detergents, pH-stabilizers, acids, and bases. Up to 75% of products contained irritant (Xi), 64% harmful (Xn) and 28% corrosive (C) labeled substances. Hazards for eyes (59%) and skin (50%), and hazards by ingestion (60%) were the most reported. Cleaning products potentially give rise to simultaneous exposures to different chemical substances. As professional cleaners represent a large workforce, and cleaning products are widely used, it is a major public health issue to better understand these exposures. The list of substances provided in this study contains important information for future occupational exposure assessment studies.

  2. The use of household cleaning sprays and adult asthma: an international longitudinal study.

    PubMed

    Zock, Jan-Paul; Plana, Estel; Jarvis, Deborah; Antó, Josep M; Kromhout, Hans; Kennedy, Susan M; Künzli, Nino; Villani, Simona; Olivieri, Mario; Torén, Kjell; Radon, Katja; Sunyer, Jordi; Dahlman-Hoglund, Anna; Norbäck, Dan; Kogevinas, Manolis

    2007-10-15

    Cleaning work and professional use of certain cleaning products have been associated with asthma, but respiratory effects of nonprofessional home cleaning have rarely been studied. To investigate the risk of new-onset asthma in relation to the use of common household cleaners. Within the follow-up of the European Community Respiratory Health Survey in 10 countries, we identified 3,503 persons doing the cleaning in their homes and who were free of asthma at baseline. Frequency of use of 15 types of cleaning products was obtained in a face-to-face interview at follow-up. We studied the incidence of asthma defined as physician diagnosis and as symptoms or medication usage at follow-up. Associations between asthma and the use of cleaning products were evaluated using multivariable Cox proportional hazards or log-binomial regression analysis. The use of cleaning sprays at least weekly (42% of participants) was associated with the incidence of asthma symptoms or medication (relative risk [RR], 1.49; 95% confidence interval [CI], 1.12-1.99) and wheeze (RR, 1.39; 95% CI, 1.06-1.80). The incidence of physician-diagnosed asthma was higher among those using sprays at least 4 days per week (RR, 2.11; 95% CI, 1.15-3.89). These associations were consistent for subgroups and not modified by atopy. Dose-response relationships (P < 0.05) were apparent for the frequency of use and the number of different sprays. Risks were predominantly found for the commonly used glass-cleaning, furniture, and air-refreshing sprays. Cleaning products not applied in spray form were not associated with asthma. Frequent use of common household cleaning sprays may be an important risk factor for adult asthma.

  3. Hazardous substances in frequently used professional cleaning products

    PubMed Central

    Gerster, Fabian Melchior; Vernez, David; Wild, Pascal Pierre; Hopf, Nancy Brenna

    2014-01-01

    Background: A growing number of studies have identified cleaners as a group at risk for adverse health effects of the skin and the respiratory tract. Chemical substances present in cleaning products could be responsible for these effects. Currently, only limited information is available about irritant and health hazardous chemical substances found in cleaning products. We hypothesized that chemical substances present in cleaning products are known health hazardous substances that might be involved in adverse health effects of the skin and the respiratory tract. Methods: We performed a systematic review of cleaning products used in the Swiss cleaning sector. We surveyed Swiss professional cleaning companies (n = 1476) to identify the most used products (n = 105) for inclusion. Safety data sheets (SDSs) were reviewed and hazardous substances present in cleaning products were tabulated with current European and global harmonized system hazard labels. Results: Professional cleaning products are mixtures of substances (arithmetic mean 3.5±2.8), and more than 132 different chemical substances were identified in 105 products. The main groups of chemicals were fragrances, glycol ethers, surfactants, solvents; and to a lesser extent, phosphates, salts, detergents, pH-stabilizers, acids, and bases. Up to 75% of products contained irritant (Xi), 64% harmful (Xn) and 28% corrosive (C) labeled substances. Hazards for eyes (59%) and skin (50%), and hazards by ingestion (60%) were the most reported. Conclusions: Cleaning products potentially give rise to simultaneous exposures to different chemical substances. As professional cleaners represent a large workforce, and cleaning products are widely used, it is a major public health issue to better understand these exposures. The list of substances provided in this study contains important information for future occupational exposure assessment studies. PMID:24804339

  4. Integrating Salmon Recovery, Clean Water Act Compliance ...

    EPA Pesticide Factsheets

    "The South Fork Nooksack River (SFNR) is an important tributary to the Nooksack River, Bellingham Bay, and the Salish Sea. The South Fork Nooksack River comprises one of the 22 independent populations of spring Chinook in the Puget Sound Chinook Evolutionarily Significant Unit (ESU), which are listed as threatened under the Endangered Species Act (ESA). The population is considered essential for recovery of the ESU. The SFNR has suffered from legacy impacts, temperature exceedances and fine sediment, due to forestry, agriculture, flood control, and transportation facilities. The temperature exceedances threaten spring Chinook salmon survival and as such under the Clean Water Act, this pollution must be addressed through a total maximum daily load (TMDL) regulatory program. Further, climate change is projected to cumulatively add to the existing legacy impacts. Millions of dollars are spent on salmon habitat restoration in the SFNR that primarily addresses these legacy impacts, but few if any restoration actions take climate change into direct consideration. The Nooksack Indian Tribe and USEPA-ORD jointly completed a climate change pilot research project that addresses legacy impacts, ESA recovery actions, CWA regulatory compliance, and salmon habitat restoration in one comprehensive project. The project evaluates how land use impacts, including altered hydrology, stream temperature, sediment dynamics, and flooding of adjacent river floodplains, combined with pr

  5. The effect of chlorination and hydrodynamic shear stress on the persistence of bacteriophages associated with drinking water biofilms.

    PubMed

    Pelleieux, S; Mathieu, L; Block, J-C; Gantzer, C; Bertrand, I

    2016-10-01

    This work aimed to assess at pilot scale the effect of chlorination and water flushing on 2-month-old drinking water biofilms and, above all, on biofilm-associated F-specific RNA bacteriophages MS2, GA and Qβ. Chlorination (4 mg l(-1) ) was applied first with a hydrodynamic shear stress of 1 Pa and second with an increase in hydrodynamic shear stress to 10 Pa. Despite a rapid decrease in the number of biofilm bacteria and associated phages, infectious phages were still detected on surfaces after completion of the 150 min cleaning procedure. The resulting sequence of phage removal was: GA > Qβ ≫ MS2. The effect of chlorine on biofilm bacteria and biofilm-associated phages was limited to the upper layers of the biofilm and was not enhanced by an increase in hydrodynamic shear stress. A smaller decrease was observed for MS2 than for GA or Qβ after completion of the cleaning procedure. The differences observed between the three phages suggest that the location of the viral particles in the biofilm, which is related to their surface properties, affects the efficiency of chlorine disinfection. © 2016 The Society for Applied Microbiology.

  6. Evaluation of HEPA vacuum cleaning and dry steam cleaning in reducing levels of polycyclic aromatic hydrocarbons and house dust mite allergens in carpets

    PubMed Central

    Yu, Chang Ho; Yiin, Lih-Ming; Fan, Zhi-Hua (Tina); Rhoads, George G.

    2014-01-01

    Dry steam cleaning, which has gained recent attention as an effective method to reduce house dust mite (HDM) allergen concentration and loading in carpets, was evaluated in this study for its efficacy in lowering levels of polycyclic aromatic hydrocarbons (PAHs) as well as HDM allergens. Fifty urban homes with wail-to-wall carpets, mostly low-income and with known lead contamination, were studied in 2003 and 2004. Two carpet-cleaning interventions were compared: Repeated HEPA (High Efficiency Particulate Air filtered) vacuuming alone and repeated HEPA vacuuming supplemented with dry steam cleaning. Vacuum samples were collected to measure carpet loading of dust and contaminants immediately before and after cleaning. Paired comparisons were conducted to evaluate the effectiveness of the cleaning protocols in reducing the levels of PAHs and HDM allergens in carpets. The results indicated that both cleaning methods substantially reduced the loading of PAHs and HDM allergens as well as dust in carpets (p < 0.0001). The reductions in loading of dust (64.4%), PAHs (69.1%), and HDM allergens (85.5%), by dry steam cleaning plus repetitive HEPA vacuuming were larger than the reductions by regular HEPA vacuuming alone: dust (55.5%), PAHs (58.6%), and HDM allergens (80.8%), although the difference was statistically significant only for dust and PAHs. We conclude that intensive HEPA vacuum cleaning substantially reduced the loading of PAHs and HDM allergens in carpets in these urban homes and that dry steam cleaning added modestly to cleaning effectiveness. PMID:19137159

  7. A perspective study on green cleaning for Malaysian public hospital

    NASA Astrophysics Data System (ADS)

    Ramli, N. A.; Zawawi, E. M.; Arif, N. R. M.; Mahbob, N. S.; Sulaiman, Z.; Zainol, N. N.

    2018-02-01

    Cleaning being a major contributor to the operations and maintenance expenditure and also Indoor Environmental Quality (IEQ) issues. Improper and ineffective cleaning can harm the environment and poses greatest risk to health. The use of traditional cleaning products presents a variety of human health and ecological concerns; and may contribute to poor IEQ. As an effort to reduce the issue of operations and maintenance costs and IEQ issues in a building, it is important to establish a green cleaning programme to ensure that the buildings are cleaned in a green way. Numbers of scholars has pointed out the factors which had prevented the green cleaning implementation in hospital buildings. Nonetheless, the significance of these factors has yet to be practically explored in the Malaysian context. Hence, the aim of the paper is to identify the most critical factor that prevents the implementation of green cleaning in Malaysian hospital building. A questionnaire survey and personal communication (i.e. interview) was conducted which involved two groups of respondents. They are the hospital maintenance staff (Cleansing Service Department) and cleaning contractors. Frequency and criticality index calculations have been used to rank these factors according to the level of importance. The result showed that an “unclear components and requirements of green cleaning” indicated as the most critical factor that prevent the implementation of green cleaning in Malaysian hospital building. In the concern for a successful implementation of green cleaning, it is hope that the findings of these studies can be enlightenment to the cleaning contractors as well as the hospital maintenance management team in Malaysia.

  8. Identifying opportunities to enhance environmental cleaning in 23 acute care hospitals .

    PubMed

    Carling, P C; Parry, M F; Von Beheren, S M

    2008-01-01

    The quality of environmental hygiene in hospitals is under increasing scrutiny from both healthcare providers and consumers because the prevalence of serious infections due to multidrug-resistant pathogens has reached alarming levels. On the basis of the results from a small number of hospitals, we undertook a study to evaluate the thoroughness of disinfection and cleaning in the patient's immediate environment and to identify opportunities for improvement in a diverse group of acute care hospitals. Prospective multicenter study to evaluate the thoroughness of terminal room cleaning in hospitals using a novel targeting method to mimic the surface contamination of objects in the patient's immediate environment. Twenty-three acute care hospitals. The overall thoroughness of terminal cleaning, expressed as a percentage of surfaces evaluated, was 49% (range for all 23 hospitals, 35%-81%). Despite the tight clustering of overall cleaning rates in 21 of the hospitals, there was marked variation within object categories, which was particularly notable with respect to the cleaning of toilet handholds, bedpan cleaners, light switches, and door knobs (mean cleaning rates, less than 30%; institutional ranges, 0%-90%). Sinks, toilet seats, and tray tables, in contrast, were consistently relatively well cleaned (mean cleaning rates, over 75%). Patient telephones, nurse call devices, and bedside rails were inconsistently cleaned. We identified significant opportunities in all participating hospitals to improve the cleaning of frequently touched objects in the patient's immediate environment. The information obtained from such assessments can be used to develop focused administrative and educational interventions that incorporate ongoing feedback to the environmental services staff, to improve cleaning and disinfection practices in healthcare institutions.

  9. Model-based Extracted Water Desalination System for Carbon Sequestration

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gettings, Rachel; Dees, Elizabeth

    The focus of this research effort centered around water recovery from high Total Dissolved Solids (TDS) extracted waters (180,000 mg/L) using a combination of water recovery (partial desalination) technologies. The research goals of this project were as follows: 1. Define the scope and test location for pilot-scale implementation of the desalination system, 2.Define a scalable, multi-stage extracted water desalination system that yields clean water, concentrated brine, and, salt from saline brines, and 3. Validate overall system performance with field-sourced water using GE pre-pilot lab facilities. Conventional falling film-mechanical vapor recompression (FF-MVR) technology was established as a baseline desalination process. Amore » quality function deployment (QFD) method was used to compare alternate high TDS desalination technologies to the base case FF-MVR technology, including but not limited to: membrane distillation (MD), forward osmosis (FO), and high pressure reverse osmosis (HPRO). Technoeconomic analysis of high pressure reverse osmosis (HPRO) was performed comparing the following two cases: 1. a hybrid seawater RO (SWRO) plus HPRO system and 2. 2x standard seawater RO system, to achieve the same total pure water recovery rate. Pre-pilot-scale tests were conducted using field production water to validate key process steps for extracted water pretreatment. Approximately 5,000 gallons of field produced water was processed through, microfiltration, ultrafiltration, and steam regenerable sorbent operations. Improvements in membrane materials of construction were considered as necessary next steps to achieving further improvement in element performance at high pressure. Several modifications showed promising results in their ability to withstand close to 5,000 PSI without gross failure.« less

  10. Optimized MBR for greywater reuse systems in hotel facilities.

    PubMed

    Atanasova, Natasa; Dalmau, Montserrat; Comas, Joaquim; Poch, Manel; Rodriguez-Roda, Ignasi; Buttiglieri, Gianluigi

    2017-05-15

    Greywater is an important alternative water source, particularly in semi-arid, touristic areas, where the biggest water demand is usually in the dry period. By using this source wisely, tourist facilities can substantially reduce the pressure to scarce water resources. In densely urbanized touristic areas, where space has high value, compact solutions such as MBR based greywater reuse systems appear very appropriate. This research focuses on technical and economical evaluation of such solution by implementing a pilot MBR to a hotel with separated grey water. The pilot was operated for 6 months, with thorough characterisation of the GW performed, its operation was monitored and its energy consumption was optimized by applying a control system for the air scour. Based on the pilot operation a design and economic model was set to estimate the feasibility (CAPEX, OPEX, payback period of investment) of appropriate scales of MBR based GW systems, including separation of GW, MBR technology, clean water storage and disinfection. The model takes into account water and energy prices in Spain and a planning period of 20 years. The results demonstrated an excellent performance in terms of effluent quality, while the energy demand for air-scour was reduced by up to 35.2%, compared to the manufacturer recommendations. Economical evaluation of the entire MBR based GW reuse system shows its feasibility for sizes already at 5 m 3 /day (60 PE). The payback period of the investment for hotels like the demonstration hotel, treating 30 m 3 /day is 3 years. Copyright © 2017 Elsevier Ltd. All rights reserved.

  11. Multiple Information Failure: A Case of Different Investments in Form and Content in Graphic Design

    ERIC Educational Resources Information Center

    Barnes, Carolyn; Taffe, Simone; Miceli, Lucy

    2009-01-01

    This paper considers a sequence of failures in the design of information. It focuses on the Safe and Sustainable Indoor Cleaning study (SASI Clean), a 2007 government-funded study into cleaning practices in Australian childcare centers. Empowerment through participation was integral to the study, childcare workers being seen as collaborators in…

  12. [Analysis and research on cleaning points of HVAC systems in public places].

    PubMed

    Yang, Jiaolan; Han, Xu; Chen, Dongqing; Jin, Xin; Dai, Zizhu

    2010-03-01

    To analyze cleaning points of HVAC systems, and to provides scientific base for regulating the cleaning of HVAC systems. Based on the survey results on the cleaning situation of HVAC systems around China for the past three years, we analyzes the cleaning points of HVAC systems from various aspects, such as the major health risk factors of HVAC systems, the formulation strategy of the cleaning of HVAC systems, cleaning methods and acceptance points of the air ducts and the parts of HVAC systems, the onsite protection and individual protection, the waste treatment and the cleaning of the removed equipment, inspection of the cleaning results, video record, and the final acceptance of the cleaning. The analysis of the major health risk factors of HVAC systems and the formulation strategy of the cleaning of HVAC systems is given. The specific methods for cleaning the air ducts, machine units, air ports, coil pipes and the water cooling towers of HVAC systems, the acceptance points of HVAC systems and the requirements of the report on the final acceptance of the cleaning of HVAC systems are proposed. By the analysis of the points of the cleaning of HVAC systems and proposal of corresponding measures, this study provides the base for the scientific and regular launch of the cleaning of HVAC systems, a novel technology service, and lays a foundation for the revision of the existing cleaning regulations, which may generate technical and social benefits to some extent.

  13. Implementing a pilot work injury management program in Hong Kong.

    PubMed

    Lai, Hon-Sun; Chan, Chetwyn C H

    2007-12-01

    This paper reports the results of implementing a pilot case management system for work injuries in Hong Kong. The case management approach was characterized by use of a case manager who worked closely with each of the reported injury cases. The case manager undertook the roles of assessor, referral agent, counselor, work-site liaison, and return-to-work (RTW) expert. A quasi-experimental study design was used. The study compared the RTW and workers' compensation outcomes in injured workers in a cleaning company in a case management group (n = 296) and a conventional rehabilitation group (n = 137). Outcomes of the intervention were followed up at 6 months. The results indicated that the RTW rate was 97.0% and 94.2% for the case management and conventional rehabilitation groups respectively, with no significant differences between them. Participants in the case management group had significantly fewer days of sick leave (mean = 27.5 and 41.6 days, respectively) and lower compensation costs (mean = HK$7,212.2 and $20,617.3, respectively) than those in the comparison group. Age of the participants was found to influence the outcomes with those who were between 41 and 50 years old and received case management intervention had shorter sick leave and lower cost of compensation than their conventional rehabilitation counterpart. The majority of the participants who had returned to work in both the case management (95.8%) and the conventional rehabilitation (96.2%) groups were found to maintain their work status 6 months after the intervention. The findings suggested that applying the case management approach to the Hong Kong workers' compensation system was more effective overall. Nevertheless, the inherent problems associated with implementing such an approach within the existing system, which focuses on compensation and medical interventions, remained unresolved.

  14. Development and application of a new biotechnology of the molasses in-situ method; detailed evaluation for selected wells in the Romashkino carbonate reservoir

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wagner, M.; Lungerhausen, D.; Murtada, H.

    1995-12-31

    On the basis of different laboratory studies, by which special strains of the type Clostridium tyrobutyricum were found, the application of molasses in-situ method for the enhanced recovery of oil in Romashkino oil field was executed. In an anaerobic, 6%-molasses medium the strains produce about 11,400 mg/l of organic acids (especially butyric acid), 3,200 mg/l ethanol, butanol, etc., and more than 350 ml/g of molasses biogas with a content of 80% C0{sub 2} and 20% H{sub 2}. The metabolics of Clostridium tyrobutyricum depress the growth of SRB, whereas methanogenic bacteria grow in an undiluted fermented molasses medium very well. Inmore » this way the dominant final fermentation process is methanogenesis. By laboratory studies with original cores under the conditions of the carbonate reservoir in Bashkir, the recovery of oil increased from 15% after waterflooding to 29% OOIP during the treatment with molasses and bacteria. We developed a new biotechnological method for a self-regulated, automatic continuous culture and constructed a special pilot plant with a high technical standard. The plant produced during the pilot on Romashkino field (September 1992 to August 1994) about 1,000 m{sup 3} of clean inoculum with a content of 3-4 billion cells per ml. This inoculum was injected in slugs together with 15,000 m{sup 3} of molasses medium, first in one, later in five wells. We will demonstrate for two example wells the complex microbiological and chemical changes in the oil, gas, and water phases, and their influences on the recover of oil.« less

  15. Impacts of Residual Surfactant on Tetrachloroethene (PCE) Degradation Following Pilot-Scale SEAR Treatment at a Chloroethene-Impacted Site

    NASA Astrophysics Data System (ADS)

    Ramsburg, C. A.; Abriola, L. M.; Pennell, K. D.; Löffler, F. E.; Gamache, M.; Petrovskis, E. A.

    2003-04-01

    A pilot-scale surfactant-enhanced aquifer remediation (SEAR) demonstration was completed during the summer of 2000 at the Bachman Road site (Oscoda, MI USA). For this test, an aqueous solution of 60 g/L Tween 80 (polyoxyethylene (20) sorbitan monooleate) was used to recover tetrachloroethene (PCE) from a suspected source zone, located underneath a former dry-cleaning facility. Tween 80 was selected for use based upon its demonstrated capacity to solubilize PCE, “food-grade” status, and biodegradative potential. Hydraulic control was maintained throughout the test, with 95% of the injected surfactant mass recovered by a single extraction well. Source-zone monitoring conducted 15 months after SEAR treatment revealed the presence of previously undetected volatile fatty acids (acetate and formate) and PCE degradation products (trichloroethene, cis-1,2-dichloroethene, trans-1,2-dichlorethene, and vinyl chloride), in conjunction with PCE concentration reductions of approximately two orders-of-magnitude. The detection of volatile fatty acids is relevant, as they are likely fermentation products of residual Tween 80. Microbial reductive dechlorination is limited by available electron donors, and microcosm studies demonstrated that both acetate and formate support reductively dechlorinating populations present at the oligotrophic Bachman Road site aquifer. Surfactant transport simulations, using a regional flow model developed for the site, were employed to determine appropriate down-gradient monitoring locations. Drive point samples taken 15 months post-treatment in the vicinity of the simulated residual surfactant plume, contained elevated concentrations of acetate and PCE daughter products. Ongoing efforts include continued site-monitoring, and microcosm studies to corroborate a causal relationship between Tween 80 fermentation and PCE dechlorination.

  16. A workforce-based study of occupational exposures and asthma symptoms in cleaning workers.

    PubMed

    Vizcaya, David; Mirabelli, Maria C; Antó, Josep-Maria; Orriols, Ramon; Burgos, Felip; Arjona, Lourdes; Zock, Jan-Paul

    2011-12-01

    To study associations between use of cleaning products and asthma symptoms in cleaning workers. Information on respiratory symptoms, history of asthma, workplaces, use of cleaning products and acute inhalation incidents were obtained through a self-administered questionnaire. 917 employees of 37 cleaning companies in Barcelona were studied. 761 (83%) were current cleaners, 86 (9%) former cleaners and 70 (8%) had never worked as cleaners. Multivariable logistic regression analyses were used to evaluate the associations between specific exposures among current cleaners and wheeze without having a cold, chronic cough and current asthma. Associations with an asthma symptom score were also studied using negative binomial regression analyses to report mean ratios. After adjusting for sex, age, nationality and smoking status, the prevalence of current asthma was non-significantly higher among current (OR 1.9; 95% CI 0.5 to 7.8) and former cleaners (OR 1.9; CI 0.6 to 5.5) than in never cleaners. Cleaners working in hospitals during the last year had a significantly increased prevalence of wheeze, current asthma and a 1.8 (95% CI 1.2 to 2.8) times higher mean asthma score. Use of hydrochloric acid was strongly associated with asthma score (mean ratio 1.7; 95% CI 1.1 to 2.6). Use of ammonia, degreasers, multiple purpose products and waxes was also associated with asthma score. Cleaning work in places with high demand for disinfection, high cleaning standards and use of cleaning products containing respiratory irritants is associated with higher risk of asthma symptoms. This suggests irritants have an important role in cleaning-related asthma.

  17. Clean cord care practices and neonatal mortality: evidence from rural Uttar Pradesh, India.

    PubMed

    Agrawal, Praween K; Agrawal, Sutapa; Mullany, Luke C; Darmstadt, Gary L; Kumar, Vishwajeet; Kiran, Usha; Ahuja, Ramesh C; Srivastava, Vinod K; Santosham, Mathuram; Black, Robert E; Baqui, Abdullah H

    2012-08-01

    About a million newborns die each year in India, accounting for about a fourth of total global neonatal deaths. Infections are among the leading causes of neonatal mortality. Care practices immediately following delivery contribute to newborns' risk of infection and mortality. This study examined the association between clean cord care practices and neonatal mortality in rural Uttar Pradesh, India. The study used data from a household survey conducted to evaluate a community-based intervention program in two districts of Uttar Pradesh, India. Analysis included data from 5741 singleton live births delivered at home during 2005. The association between clean cord care (clean instrument used to cut cord, clean thread used to tie cord and antiseptics or nothing applied to the cord) and neonatal mortality was estimated using multivariate logistic regression models. Thirty per cent of the study mothers practiced clean cord care. Neonatal mortality rate was significantly lower among newborns exposed to clean cord care (36.5/1000 live births, 95% CI 28.0 to 46.8) than those who did not practice (53.0/1000 live births, 95% CI 46.1 to 60.6). Clean cord care was associated with 37% lower neonatal mortality (OR=0.63; 95% CI 0.46 to 0.87) after adjusting for mother's age, education, caste/tribe, religion, household wealth, newborn thermal care practice and care-seeking during the first week after birth and study arms. Promoting clean cord care practice among neonates in community-based maternal and newborn care programs has the potential to improve neonatal survival in rural India and similar other settings.

  18. Supersonic Gas-Liquid Cleaning System

    NASA Technical Reports Server (NTRS)

    Kinney, Frank

    1996-01-01

    The Supersonic Gas-Liquid Cleaning System Research Project consisted mainly of a feasibility study, including theoretical and engineering analysis, of a proof-of-concept prototype of this particular cleaning system developed by NASA-KSC. The cleaning system utilizes gas-liquid supersonic nozzles to generate high impingement velocities at the surface of the device to be cleaned. The cleaning fluid being accelerated to these high velocities may consist of any solvent or liquid, including water. Compressed air or any inert gas is used to provide the conveying medium for the liquid, as well as substantially reduce the total amount of liquid needed to perform adequate surface cleaning and cleanliness verification. This type of aqueous cleaning system is considered to be an excellent way of conducting cleaning and cleanliness verification operations as replacements for the use of CFC 113 which must be discontinued by 1995. To utilize this particular cleaning system in various cleaning applications for both the Space Program and the commercial market, it is essential that the cleaning system, especially the supersonic nozzle, be characterized for such applications. This characterization consisted of performing theoretical and engineering analysis, identifying desirable modifications/extensions to the basic concept, evaluating effects of variations in operating parameters, and optimizing hardware design for specific applications.

  19. Washing away your sins in the brain: physical cleaning and priming of cleaning recruit different brain networks after moral threat

    PubMed Central

    Tang, Honghong; Lu, Xiaping; Su, Rui; Liang, Zilu; Mai, Xiaoqin

    2017-01-01

    Abstract The association between moral purity and physical cleanliness has been widely discussed recently. Studies found that moral threat initiates the need of physical cleanliness, but actual physical cleaning and priming of cleaning have inconsistent effects on subsequent attitudes and behaviors. Here, we used resting-state functional magnetic resonance imaging to explore the underlying neural mechanism of actual physical cleaning and priming of cleaning. After recalling moral transgression with strong feelings of guilt and shame, participants either actually cleaned their faces with a wipe or were primed with cleanliness through viewing its pictures. Results showed that actual physical cleaning reduced the spontaneous brain activities in the right insula and MPFC, regions that involved in embodied moral emotion processing, while priming of cleaning decreased activities in the right superior frontal gyrus and middle frontal gyrus, regions that participated in executive control processing. Additionally, actual physical cleaning also changed functional connectivity between insula/MPFC and emotion related regions, whereas priming of cleaning modified connectivity within both moral and sensorimotor areas. These findings revealed that actual physical cleaning and priming of cleaning led to changes in different brain regions and networks, providing neural evidence for the inconsistent effects of cleanliness on subsequent attitudes and behaviors. PMID:28338887

  20. Washing away your sins in the brain: physical cleaning and priming of cleaning recruit different brain networks after moral threat.

    PubMed

    Tang, Honghong; Lu, Xiaping; Su, Rui; Liang, Zilu; Mai, Xiaoqin; Liu, Chao

    2017-07-01

    The association between moral purity and physical cleanliness has been widely discussed recently. Studies found that moral threat initiates the need of physical cleanliness, but actual physical cleaning and priming of cleaning have inconsistent effects on subsequent attitudes and behaviors. Here, we used resting-state functional magnetic resonance imaging to explore the underlying neural mechanism of actual physical cleaning and priming of cleaning. After recalling moral transgression with strong feelings of guilt and shame, participants either actually cleaned their faces with a wipe or were primed with cleanliness through viewing its pictures. Results showed that actual physical cleaning reduced the spontaneous brain activities in the right insula and MPFC, regions that involved in embodied moral emotion processing, while priming of cleaning decreased activities in the right superior frontal gyrus and middle frontal gyrus, regions that participated in executive control processing. Additionally, actual physical cleaning also changed functional connectivity between insula/MPFC and emotion related regions, whereas priming of cleaning modified connectivity within both moral and sensorimotor areas. These findings revealed that actual physical cleaning and priming of cleaning led to changes in different brain regions and networks, providing neural evidence for the inconsistent effects of cleanliness on subsequent attitudes and behaviors. © The Author (2017). Published by Oxford University Press.

  1. Manual methods are suboptimal compared with automated methods for cleaning of single-use biopsy forceps.

    PubMed

    Alfa, M J; Nemes, R; Olson, N; Mulaire, A

    2006-08-01

    Most reusable biopsy forceps and all of the currently available single-use biopsy forceps do not have a port that allows fluid flow down the inner tubular shaft of the device. Reusable biopsy forceps are widely used and reprocessed in healthcare facilities, and single-use biopsy forceps are reprocessed either in-house (eg, in Canada and Japan) or by third-party reprocessors (eg, in the United States). The objective of this study was to determine the cleaning efficacy of automated narrow-lumen sonic irrigation cleaning, sonication-only cleaning, and manual cleaning for biopsy forceps. A simulated-use study was performed by inoculating the inner channel of single-use biopsy forceps with artificial test soil containing both Enterococcus faecalis and Geobacillus stearothermophilus at concentrations of 10(6) colony-forming units per milliliter. The cleaning methods evaluated were manual cleaning, sonication-only cleaning, and "retroflush" cleaning by an automated narrow-lumen irrigator. Bioburden and organic soil reduction after washing was evaluated. Forceps used in biopsies of patients were also tested to determine the worst-case soiling levels. Only retroflush irrigation cleaning could effectively remove material from within the shaft portion of the biopsy forceps: it achieved an average reduction of more than 95% in levels of protein, hemoglobin, carbohydrate, and endotoxin. However, even this method of cleaning was not totally effective, as only a 2 log10 reduction in bioburden could be achieved, and there were low residual levels of hemoglobin and carbohydrate. The data from this evaluation indicate that manual and sonication-only cleaning methods for biopsy forceps were totally ineffective in removing material from within the biopsy forceps. Even the use of retroflush cleaning was not totally effective. These findings suggest that in-hospital reprocessing of biopsy forceps with currently available equipment and cleaning methods is suboptimal.

  2. Comparison of sampling procedures and microbiological and non-microbiological parameters to evaluate cleaning and disinfection in broiler houses.

    PubMed

    Luyckx, K; Dewulf, J; Van Weyenberg, S; Herman, L; Zoons, J; Vervaet, E; Heyndrickx, M; De Reu, K

    2015-04-01

    Cleaning and disinfection of the broiler stable environment is an essential part of farm hygiene management. Adequate cleaning and disinfection is essential for prevention and control of animal diseases and zoonoses. The goal of this study was to shed light on the dynamics of microbiological and non-microbiological parameters during the successive steps of cleaning and disinfection and to select the most suitable sampling methods and parameters to evaluate cleaning and disinfection in broiler houses. The effectiveness of cleaning and disinfection protocols was measured in six broiler houses on two farms through visual inspection, adenosine triphosphate hygiene monitoring and microbiological analyses. Samples were taken at three time points: 1) before cleaning, 2) after cleaning, and 3) after disinfection. Before cleaning and after disinfection, air samples were taken in addition to agar contact plates and swab samples taken from various sampling points for enumeration of total aerobic flora, Enterococcus spp., and Escherichia coli and the detection of E. coli and Salmonella. After cleaning, air samples, swab samples, and adenosine triphosphate swabs were taken and a visual score was also assigned for each sampling point. The mean total aerobic flora determined by swab samples decreased from 7.7±1.4 to 5.7±1.2 log CFU/625 cm2 after cleaning and to 4.2±1.6 log CFU/625 cm2 after disinfection. Agar contact plates were used as the standard for evaluating cleaning and disinfection, but in this study they were found to be less suitable than swabs for enumeration. In addition to measuring total aerobic flora, Enterococcus spp. seemed to be a better hygiene indicator to evaluate cleaning and disinfection protocols than E. coli. All stables were Salmonella negative, but the detection of its indicator organism E. coli provided additional information for evaluating cleaning and disinfection protocols. Adenosine triphosphate analyses gave additional information about the hygiene level of the different sampling points. © 2015 Poultry Science Association Inc.

  3. Ultrasonic cleaning of conveyor belt materials using Listeria monocytogenes as a model organism.

    PubMed

    Tolvanén, Riina; Lunden, Janne; Korkeala, Hannu; Wirtanen, Gun

    2007-03-01

    Persistent Listeria monocytogenes contamination of food industry equipment is a difficult problem to solve. Ultrasonic cleaning offers new possibilities for cleaning conveyors and other equipment that are not easy to clean. Ultrasonic cleaning was tested on three conveyor belt materials: polypropylene, acetal, and stainless steel (cold-rolled, AISI 304). Cleaning efficiency was tested at two temperatures (30 and 45 degrees C) and two cleaning times (30 and 60 s) with two cleaning detergents (KOH, and NaOH combined with KOH). Conveyor belt materials were soiled with milk-based soil and L. monocytogenes strains V1, V3, and B9, and then incubated for 72 h to attach bacteria to surfaces. Ultrasonic cleaning treatments reduced L. monocytogenes counts on stainless steel 4.61 to 5.90 log units; on acetal, 3.37 to 5.55 log units; and on polypropylene, 2.31 to 4.40 log units. The logarithmic reduction differences were statistically analyzed by analysis of variance using Statistical Package for the Social Sciences software. The logarithmic reduction was significantly greater in stainless steel than in plastic materials (P < 0.001 for polypropylene, P = 0.023 for acetal). Higher temperatures enhanced the cleaning efficiency in tested materials. No significant difference occurred between cleaning times. The logarithmic reduction was significantly higher (P = 0.013) in cleaning treatments with potassium hydroxide detergent. In this study, ultrasonic cleaning was efficient for cleaning conveyor belt materials.

  4. Preliminary Results of Cleaning Process for Lubricant Contamination

    NASA Astrophysics Data System (ADS)

    Eisenmann, D.; Brasche, L.; Lopez, R.

    2006-03-01

    Fluorescent penetrant inspection (FPI) is widely used for aviation and other components for surface-breaking crack detection. As with all inspection methods, adherence to the process parameters is critical to the successful detection of defects. Prior to FPI, components are cleaned using a variety of cleaning methods which are selected based on the alloy and the soil types which must be removed. It is also important that the cleaning process not adversely affect the FPI process. There are a variety of lubricants and surface coatings used in the aviation industry which must be removed prior to FPI. To assess the effectiveness of typical cleaning processes on removal of these contaminants, a study was initiated at an airline overhaul facility. Initial results of the cleaning study for lubricant contamination in nickel, titanium and aluminum alloys will be presented.

  5. Cleaning painted surfaces: evaluation of leaching phenomenon induced by solvents applied for the removal of gel residues.

    PubMed

    Casoli, Antonella; Di Diego, Zaira; Isca, Clelia

    2014-12-01

    Cleaning is one of the most important, delicate, and at the same time controversial processes in the conservation treatment of paintings. Although a strict definition of cleaning would be the removal of dirt, grime, or other accretions (surface cleaning), in the conservation field, cleaning is used in the broader meaning to include thinning/removing altered or “unwanted layers” of materials without damaging or altering the physicochemical properties of the surfaces to be preserved. The cleaning of unvarnished paintings is one of the most critical issues that are currently discussed. Several studies exist regarding different cleaning tools, such as gels, soaps, enzymes, ionic liquids, and foams, as well as various dry methods and lasers, but only a few have been performed on the risk associated with the use of water and organic solvents for the cleaning treatments in relation to the original paint binder. The aim of the study is to verify analytically the behavior of water gelling agents during cleaning treatments and the interaction of the following elements: water or organic solvents applied for the removal of gel residues with the original lipid paint binder. For this purpose, the study was conducted on a fragment of canvas painting (sixteenth to seventeenth century) of Soprintendenza per i Beni Storici, Artistici ed Etnoantropologici del Friuli Venezia Giulia (Superintendence for the Historical, Artistic and Ethno-anthropological Heritage of Friuli Venezia Giulia), Udine by means of Fourier transform infrared spectroscopy, gas chromatography/mass spectrometry, and scanning electron microscopy.

  6. The importance of the location of sodium chlorite application in a multipollutant flue gas cleaning system.

    PubMed

    Krzyzynska, Renata; Hutson, Nick D

    2012-06-01

    In this study, removing sulfur dioxide (SO2), nitrogen oxides (NO(x)), and mercury (Hg) from simulated flue gas was investigated in two laboratory-sized bubbling reactors that simulated an oxidizing reactor (where the NO and Hg(0) oxidation reactions are expected to occur) and a wet limestone scrubber, respectively. A sodium chlorite solution was used as the oxidizing agent. The sodium chlorite solution was an effective additive that enhanced the NO(x), Hg, and SO2 capture from the flue gas. Furthermore, it was discovered that the location of the sodium chlorite application (before, in, or after the wet scrubber) greatly influences which pollutants are removed and the amount removed. This effect is related to the chemical conditions (pH, absence/presence of particular gases) that are present at different positions throughout the flue gas cleaning system profile. The research results indicated that there is a potential to achieve nearly zero SO2, NO(x), and Hg emissions (complete SO2, NO, and Hg removals and -90% of NO(x) absorption from initial values of 1500 ppmv of SO2, 200 ppmv of NO(x), and 206 microg/m3 of Hg(0)) from the flue gas when sodium chlorite was applied before the wet limestone scrubber. However applying the oxidizer after the wet limestone scrubber was the most effective configuration for Hg and NO(x) control for extremely low chlorite concentrations (below 0.002 M) and therefore appears to be the best configuration for Hg control or as an additional step in NO(x) recleaning (after other NO(x) control facilities). The multipollutant scrubber, into which the chlorite was injected simultaneously with the calcium carbonate slurry, appeared to be the least expensive solution (when consider only capital cost), but exhibited the lowest NO(x) absorption at -50%. The bench-scale test results presented can be used to develop performance predictions for a full- or pilot-scale multipollutant flue gas cleaning system equipped with wet flue gas desulfurization scrubber.

  7. A tutorial on pilot studies: the what, why and how

    PubMed Central

    2010-01-01

    Pilot studies for phase III trials - which are comparative randomized trials designed to provide preliminary evidence on the clinical efficacy of a drug or intervention - are routinely performed in many clinical areas. Also commonly know as "feasibility" or "vanguard" studies, they are designed to assess the safety of treatment or interventions; to assess recruitment potential; to assess the feasibility of international collaboration or coordination for multicentre trials; to increase clinical experience with the study medication or intervention for the phase III trials. They are the best way to assess feasibility of a large, expensive full-scale study, and in fact are an almost essential pre-requisite. Conducting a pilot prior to the main study can enhance the likelihood of success of the main study and potentially help to avoid doomed main studies. The objective of this paper is to provide a detailed examination of the key aspects of pilot studies for phase III trials including: 1) the general reasons for conducting a pilot study; 2) the relationships between pilot studies, proof-of-concept studies, and adaptive designs; 3) the challenges of and misconceptions about pilot studies; 4) the criteria for evaluating the success of a pilot study; 5) frequently asked questions about pilot studies; 7) some ethical aspects related to pilot studies; and 8) some suggestions on how to report the results of pilot investigations using the CONSORT format. PMID:20053272

  8. Evaluation of various cleaning methods to remove bacillus spores from spacecraft hardware materials

    NASA Technical Reports Server (NTRS)

    Venkateswaran, Kasthuri; Chung, Shirley; Allton, Judith; Kern, Roger

    2004-01-01

    A detailed study was made of the biological cleaning effectiveness, defined in terms of the ability to remove bacterial spores, of a number of methods used to clean hardware surfaces. Aluminum (Al 6061) and titanium (Ti 6Al-4V) were chosen for the study as they were deemed the two materials most likely to be used in spacecraft extraterrestrial sampler construction. Metal coupons (1 cm x 2.5 cm) were precleaned and inoculated with 5.8 x 10(3) cultivable Bacillus subtilis spores, which are commonly found on spacecraft surfaces and in the assembly environments. The inoculated coupons were subsequently cleaned using: (1) 70% isopropyl alcohol wipe; (2) water wipe; (3) multiple-solvent flight-hardware cleaning procedures used at the Jet Propulsion Laboratory (JPL); (4) Johnson Space Center-developed ultrapure water rinse; and (5) a commercial, semi-aqueous, multiple-solvent (SAMS) cleaning process. The biological cleaning effectiveness was measured by agar plate assay, sterility test (growing in liquid media), and epifluorescent microscopy. None of the cleaning protocols tested completely removed viable spores from the surface of the aluminum. In contrast, titanium was capable of being cleaned to sterility by two methods, the JPL standard and the commercial SAMS cleaning process. Further investigation showed that the passivation step employed in the JPL standard method is an effective surface sterilant on both metals but not compatible with aluminum. It is recommended that titanium (Ti 6Al-4V) be considered superior to aluminum (Al 6061) for use in spacecraft sampling hardware, both for its potential to be cleaned to sterilization and for its ability to withstand the most effective cleaning protocols.

  9. Evaluation of Various Cleaning Methods to Remove Bacillus Spores from Spacecraft Hardware Materials

    NASA Astrophysics Data System (ADS)

    Venkateswaran, Kasthuri; Chung, Shirley; Allton, Judith; Kern, Roger

    2004-09-01

    A detailed study was made of the biological cleaning effectiveness, defined in terms of the ability to remove bacterial spores, of a number of methods used to clean hardware surfaces. Aluminum (Al 6061) and titanium (Ti 6Al-4V) were chosen for the study as they were deemed the two materials most likely to be used in spacecraft extraterrestrial sampler construction. Metal coupons (1 cm × 2.5 cm) were precleaned and inoculated with 5.8 × 103 cultivable Bacillus subtilis spores, which are commonly found on spacecraft surfaces and in the assembly environments. The inoculated coupons were subsequently cleaned using: (1) 70% isopropyl alcohol wipe; (2) water wipe; (3) multiple-solvent flight-hardware cleaning procedures used at the Jet Propulsion Laboratory (JPL); (4) Johnson Space Center-developed ultrapure water rinse; and (5) a commercial, semi-aqueous, multiple-solvent (SAMS) cleaning process. The biological cleaning effectiveness was measured by agar plate assay, sterility test (growing in liquid media), and epifluorescent microscopy. None of the cleaning protocols tested completely removed viable spores from the surface of the aluminum. In contrast, titanium was capable of being cleaned to sterility by two methods, the JPL standard and the commercial SAMS cleaning process. Further investigation showed that the passivation step employed in the JPL standard method is an effective surface sterilant on both metals but not compatible with aluminum. It is recommended that titanium (Ti 6Al-4V) be considered superior to aluminum (Al 6061) for use in spacecraft sampling hardware, both for its potential to be cleaned to sterilization and for its ability to withstand the most effective cleaning protocols.

  10. Evaluation of various cleaning methods to remove bacillus spores from spacecraft hardware materials.

    PubMed

    Venkateswaran, Kasthuri; Chung, Shirley; Allton, Judith; Kern, Roger

    2004-01-01

    A detailed study was made of the biological cleaning effectiveness, defined in terms of the ability to remove bacterial spores, of a number of methods used to clean hardware surfaces. Aluminum (Al 6061) and titanium (Ti 6Al-4V) were chosen for the study as they were deemed the two materials most likely to be used in spacecraft extraterrestrial sampler construction. Metal coupons (1 cm x 2.5 cm) were precleaned and inoculated with 5.8 x 10(3) cultivable Bacillus subtilis spores, which are commonly found on spacecraft surfaces and in the assembly environments. The inoculated coupons were subsequently cleaned using: (1) 70% isopropyl alcohol wipe; (2) water wipe; (3) multiple-solvent flight-hardware cleaning procedures used at the Jet Propulsion Laboratory (JPL); (4) Johnson Space Center-developed ultrapure water rinse; and (5) a commercial, semi-aqueous, multiple-solvent (SAMS) cleaning process. The biological cleaning effectiveness was measured by agar plate assay, sterility test (growing in liquid media), and epifluorescent microscopy. None of the cleaning protocols tested completely removed viable spores from the surface of the aluminum. In contrast, titanium was capable of being cleaned to sterility by two methods, the JPL standard and the commercial SAMS cleaning process. Further investigation showed that the passivation step employed in the JPL standard method is an effective surface sterilant on both metals but not compatible with aluminum. It is recommended that titanium (Ti 6Al-4V) be considered superior to aluminum (Al 6061) for use in spacecraft sampling hardware, both for its potential to be cleaned to sterilization and for its ability to withstand the most effective cleaning protocols.

  11. Risk in cleaning: chemical and physical exposure.

    PubMed

    Wolkoff, P; Schneider, T; Kildesø, J; Degerth, R; Jaroszewski, M; Schunk, H

    1998-04-23

    Cleaning is a large enterprise involving a large fraction of the workforce worldwide. A broad spectrum of cleaning agents has been developed to facilitate dust and dirt removal, for disinfection and surface maintenance. The cleaning agents are used in large quantities throughout the world. Although a complex pattern of exposure to cleaning agents and resulting health problems, such as allergies and asthma, are reported among cleaners, only a few surveys of this type of product have been performed. This paper gives a broad introduction to cleaning agents and the impact of cleaning on cleaners, occupants of indoor environments, and the quality of cleaning. Cleaning agents are usually grouped into different product categories according to their technical functions and the purpose of their use (e.g. disinfectants and surface care products). The paper also indicates the adverse health and comfort effects associated with the use of these agents in connection with the cleaning process. The paper identifies disinfectants as the most hazardous group of cleaning agents. Cleaning agents contain evaporative and non-evaporative substances. The major toxicologically significant constituents of the former are volatile organic compounds (VOCs), defined as substances with boiling points in the range of 0 degree C to about 400 degrees C. Although laboratory emission testing has shown many VOCs with quite different time-concentration profiles, few field studies have been carried out measuring the exposure of cleaners. However, both field studies and emission testing indicate that the use of cleaning agents results in a temporal increase in the overall VOC level. This increase may occur during the cleaning process and thus it can enhance the probability of increased short-term exposure of the cleaners. However, the increased levels can also be present after the cleaning and result in an overall increased VOC level that can possibly affect the indoor air quality (IAQ) perceived by occupants. The variety and duration of the emissions depend inter alia on the use of fragrances and high boiling VOCs. Some building materials appear to increase their VOC emission through wet cleaning and thus may affect the IAQ. Particles and dirt contain a great variety of both volatile and non-volatile substances, including allergens. While the volatile fraction can consist of more than 200 different VOCs including formaldehyde, the non-volatile fraction can contain considerable amounts (> 0.5%) of fatty acid salts and tensides (e.g. linear alkyl benzene sulphonates). The level of these substances can be high immediately after the cleaning process, but few studies have been conducted concerning this problem. The substances partly originate from the use of cleaning agents. Both types are suspected to be airway irritants. Cleaning activities generate dust, mostly by resuspension, but other occupant activities may also resuspend dust over longer periods of time. Personal sampling of VOCs and airborne dust gives higher results than stationary sampling. International bodies have proposed air sampling strategies. A variety of field sampling techniques for VOC and surface particle sampling is listed.

  12. An energy-dispersive X-ray analysis and SEM study of debris remaining on endodontic instruments after ultrasonic cleaning and autoclave sterilization.

    PubMed

    Parirokh, Masoud; Asgary, Saeed; Eghbal, Mohammad Jafar

    2005-08-01

    This study was carried out to investigate metallic and non-metallic debris remaining on endodontic files after ultrasonic cleaning and autoclave processing. Forty-eight unused rotary and hand endodontic files, including eight different brands, were tested. Instruments were cleaned with ultrasound, autoclaved and before and after each step were observed by scanning electron microscopy (SEM). Adherent debris was analysed by energy-dispersive X-ray analysis (EDXA). All of the instruments before ultrasound cleaning were contaminated with metallic and non-metallic debris. Although most non-metallic debris was removed by ultrasonic cleaning, most of the metallic debris remained even after the final step of sterilization.

  13. Stethoscope Hygiene: Practice and Attitude of Medical Students

    PubMed Central

    Gazibara, Tatjana; Radovanovic, Sanja; Maric, Gorica; Rancic, Biljana; Kisic-Tepavcevic, Darija; Pekmezovic, Tatjana

    2015-01-01

    Objective The purpose of this study was to evaluate the frequency and attitude of medical students towards cleaning their stethoscopes. Subjects and Methods A cross-sectional study was carried out in the first week of December 2013. The study included 771 students (397 in their fourth and 374 in their sixth year) from the Faculty of Medicine, University of Belgrade, Serbia. An anonymous questionnaire was distributed to students before the start of compulsory lessons in classrooms. Results 317 of the 397 fourth-year students (79.8%) and 306 of the 374 sixth-year students (81.9%) cleaned their stethoscope. The stethoscope diaphragm was most commonly cleaned, while the flexible tubing was the least commonly cleaned area, mainly using ethyl alcohol-based agents. The strongest positive attitude was observed for the statement ‘It is important that my stethoscope is clean’ (4.3 out of 5.0). A positive correlation (Spearman's ρ = 0.105) was observed between a higher frequency of cleaning and the stronger positive notion that a stethoscope should be cleaned. Conclusion A considerably high proportion of the students studied had ever cleaned their stethoscopes. Based on the students' responses, it would be useful to implement instructions on stethoscope hygiene in the regular practical curriculum with the aim of applying stethoscope disinfection in daily work. PMID:26202790

  14. Evaluation of common cleaning and disinfection programmes in battery cage and on-floor layer houses in France.

    PubMed

    Huneau-Salaün, A; Michel, V; Balaine, L; Petetin, I; Eono, F; Ecobichon, F; Bouquin, S Le

    2010-04-01

    1. The aim in this study was to evaluate cleaning and disinfection programmes in battery cage and on-floor layer houses in France. 2. Cleaning and disinfection efficiency was assessed by a visual evaluation of cleaning and a bacteriological monitoring of surface contamination from counts of thermotolerant streptococci on contact agar plates. 3. In battery cage houses, dropping belts, manure conveyors, and house floors remained highly contaminated due to poor cleaning in half of the buildings examined. 4. In on-floor houses, a high standard of cleaning was achieved but errors in the planning of cleaning and disinfection operations sometimes led to a high residual contamination of nest boxes and egg sorting tables.

  15. Benefits and Costs of the Clean Air Act

    EPA Pesticide Factsheets

    Congress added to the 1990 Clean Air Act Amendments a requirement under section 812 that EPA conduct periodic, scientifically reviewed studies to assess the benefits and the costs of the entire Clean Air Act.

  16. Simulated-use validation of a sponge ATP method for determining the adequacy of manual cleaning of endoscope channels.

    PubMed

    Alfa, Michelle J; Olson, Nancy

    2016-05-04

    The objective of this study was to validate the relative light unit (RLU) cut-off of adequate cleaning of flexible colonoscopes for an ATP (adenosine tri-phosphate) test kit that used a sponge channel collection method. This was a simulated-use study. The instrument channel segment of a flexible colonoscope was soiled with ATS (artificial test soil) containing approximately 8 Log10 Enterococcus faecalis and Pseudomonas aeruginosa/mL. Full cleaning, partial cleaning and no cleaning were evaluated for ATP, protein and bacterial residuals. Channel samples were collected using a sponge device to assess residual RLUs. Parallel colonoscopes inoculated and cleaned in the same manner were sampled using the flush method to quantitatively assess protein and bacterial residuals. The protein and viable count benchmarks for adequate cleaning were <6.4 ug/cm(2) and <4 Log10 cfu/cm(2). The negative controls for the instrument channel, over the course of the study remained low with on average 14 RLUs, 0.04 ug/cm(2) protein and 0.025 Log10 cfu/cm(2). Partial cleaning resulted in an average of 6601 RLUs, 3.99 ug/cm(2), 5.25 Log10 cfu/cm(2) E. faecalis and 4.48 Log10 cfu/cm(2) P. aeruginosa. After full cleaning, the average RLU was 29 (range 7-71 RLUs) and the average protein, E. faecalis and P. aeruginosa residuals were 0.23 ug/cm(2), 0.79 and 1.61 Log10 cfu/cm(2), respectively. The validated cut-off for acceptable manual cleaning was set at ≤100 RLUs for the sponge collected channel ATP test kit.

  17. The cleaning of ward floors and the bacteriological study of floor-cleaning machines

    PubMed Central

    Bate, J. G.

    1961-01-01

    Current trends in ward flooring materials and cleaning methods are considered from the point of view of the hospital bacteriologist. Methods employed in an investigation into the bacteriological safety of a number of floor-cleaning machines are described, and some considerations governing the choice of vacuum cleaners for ward use are discussed. Images PMID:13687726

  18. KSC-08pd3742

    NASA Image and Video Library

    2008-11-19

    CAPE CANAVERAL, Fla. – At the Parachute Refurbishment Facility at NASA's Kennedy Space Center in Florida, workers begin hanging the parachutes recovered from sea after the launch of space shuttle Endeavour on the STS-126 mission onto a monorail system. The parachutes are used to slow the descent of the solid rocket boosters that are jettisoned during liftoff. The monorail will transport each parachute into a 30,000-gallon washer and a huge dryer heated with 140-degree air at 13,000 cubic feet per minute One pilot, one drogue and three main canopies per booster slow the booster’s fall from about 360 mph to 50 mph. After the chutes are cleaned and repaired, they must be carefully packed into their bags so they will deploy correctly the next time they are used. Photo credit: NASA/Jim Grossmann

  19. KSC-08pd3743

    NASA Image and Video Library

    2008-11-19

    CAPE CANAVERAL, Fla. – At the Parachute Refurbishment Facility at NASA's Kennedy Space Center in Florida, workers begin hanging the parachutes recovered from sea after the launch of space shuttle Endeavour on the STS-126 mission onto a monorail system. The parachutes are used to slow the descent of the solid rocket boosters that are jettisoned during liftoff. The monorail will transport each parachute into a 30,000-gallon washer and a huge dryer heated with 140-degree air at 13,000 cubic feet per minute. One pilot, one drogue and three main canopies per booster slow the booster’s fall from about 360 mph to 50 mph. After the chutes are cleaned and repaired, they must be carefully packed into their bags so they will deploy correctly the next time they are used. Photo credit: NASA/Jim Grossmann

  20. KSC-08pd3740

    NASA Image and Video Library

    2008-11-19

    CAPE CANAVERAL, Fla. – Parachutes recovered from sea after the launch of space shuttle Endeavour on the STS-126 mission are suspended from a hanging monorail system at the Parachute Refurbishment Facility at NASA's Kennedy Space Center in Florida. The parachutes are used to slow the descent of the solid rocket boosters that are jettisoned during liftoff. The monorail will transport each parachute into a 30,000-gallon washer and a huge dryer heated with 140-degree air at 13,000 cubic feet per minute. One pilot, one drogue and three main canopies per booster slow the booster’s fall from about 360 mph to 50 mph. After the chutes are cleaned and repaired, they must be carefully packed into their bags so they will deploy correctly the next time they are used. Photo credit: NASA/Jim Grossmann

  1. KSC-08pd3747

    NASA Image and Video Library

    2008-11-19

    CAPE CANAVERAL, Fla. – At the Parachute Refurbishment Facility at NASA's Kennedy Space Center in Florida, the parachutes recovered from sea after the launch of space shuttle Endeavour on the STS-126 mission are moved through the 30,000-gallon washer. The parachutes are used to slow the descent of the solid rocket boosters that are jettisoned during liftoff. After washing, the monorail will move the parachutes into a huge dryer heated with 140-degree air at 13,000 cubic feet per minute. One pilot, one drogue and three main canopies per booster slow the booster’s fall from about 360 mph to 50 mph. After the chutes are cleaned and repaired, they must be carefully packed into their bags so they will deploy correctly the next time they are used. Photo credit: NASA/Jim Grossmann

  2. Project Independence: Construction of an Integrated Biorefinery for Production of Renewable Biofuels at an Existing Pulp and Paper Mill

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Freeman, Douglas

    2012-06-01

    Project Independence proposed to construct a demonstration biomass-to-liquids (BTL) biorefinery in Wisconsin Rapids, isconsin. The biorefinery was to be co-located at the existing pulp and paper mill, NewPage Wisconsin System Incorporated’s Wisconsin Rapids Mill, and when in full operation would both generate renewable energy for Wisconsin Rapids Mill and produce liquid fuels from abundant and renewable lignocellulosic biomass. The biorefinery would serve to validate the thermochemical pathway and economic models for BTL production using forest residuals and wood waste, providing a basis for proliferating BTL conversion technologies throughout the United States. It was a project goal to create a compellingmore » new business model for the pulp and paper industry, and support the nation’s goal for increasing renewable fuels production and reducing its dependence on foreign oil. NewPage Corporation planned to replicate this facility at other NewPage Corporation mills after this first demonstration scale plant was operational and had proven technical and economic feasibility. An overview of the process begins with biomass being harvested, sized, conditioned and fed into a ThermoChem Recovery International (TRI) steam reformer where it is converted to high quality synthetic gas (syngas). The syngas is then cleaned, compressed, scrubbed, polished and fed into the Fischer-Tropsch (F-T) catalytic reactors where the gas is converted into two, sulfur-free, clean crude products which will be marketed as revenue generating streams. Additionally, the Fischer-Tropsch products could be upgraded for use in automotive, aviation and chemical industries as valuable products, if desired. As the Project Independence project set out to prove forest products could be used to commercially produce biofuels, they planned to address and mitigate issues as they arose. In the early days of the Project Independence project, the plant was sized to process 500 dry tons of biomass per day but would generate a blend of synthesis gas for the lime kiln and a minimum of Fischer-Tropsch liquids for sale. This was to be done using a single stage of Fischer-Tropsch reaction at roughly a 70% yield. The capability of the Wisconsin Rapids Mill lime kiln to run on the relatively low heating value of the product synthesis gas was problematic. The design was then changed to maximize Fischer-Tropsch liquids production using a two stage Fischer-Tropsch process. Project Independence progressed with the design of the mill as ThermoChem Recovery International worked on the technical details of the project as well as develop information from their pilot plant. The pilot plant work uncovered several problems with the synthesis gas clean-up that solutions. ThermoChem Recovery International found these solutions and developed a very good path forward on the technical side. The technical solutions were demonstrated in the pilot plant to everyone’s satisfaction. In July 2010, NewPage Corporation had been severely affected by the downturn in the economy and actively went to find a strategic partner. By April 2011 the Abell Foundation entered the picture as this strategic partner. The Abell Foundation would join forces as Project Independence Inc. to build the 500 dry ton per day Project Independence plant. The design of this facility progress even after NewPage Corporation declared Chapter 11 Bankruptcy protection in September, 2011. This continued until April 2012 when NewPage Corporation determined that continued work on Project Independence Inc. presented too much risk with little reward for NewPage Corporation. The project was terminated at this point.« less

  3. Evaluation of two cleaning methods for the removal of asbestos fibers from carpet

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kominsky, J.R.; Freyberg, R.W.; Chesson, J.

    The research study examined the effectiveness of dry vacuuming and wet cleaning for the removal of asbestos fibers from carpet, and evaluated the potential for fiber reentrainment during carpet cleaning activities. Routine carpet cleaning operations using high-efficiency particulate air (HEPA) filtered dry vacuum cleaners and HEPA-filtered hot-water extraction cleaners were simulated on carpet artificially contaminated with asbestos fibers. Overall, wet cleaning the carpet with a hot-water extraction cleaner reduced the level of asbestos contamination by approximately 70 percent. There was no significant evidence of either an increase or a decrease in the asbestos concentration after dry vacuuming. The level ofmore » asbestos contamination had no significant effect on the difference between the carpet asbestos concentrations before and after cleaning. Airborne asbestos concentrations were between two and four times greater during the carpet cleaning activities. The level of asbestos contamination in the carpet cleaning activities. The level of asbestos contamination in the carpet and the type of cleaning method used had no statistically significant effect on the difference between the airborne asbestos concentrations before and during cleaning.« less

  4. Designing and Testing of Self-Cleaning Recirculating Zebrafish Tanks.

    PubMed

    Nema, Shubham; Bhargava, Yogesh

    2016-08-01

    Maintenance of large number of zebrafish in captive conditions is a daunting task. This can be eased by the use of recirculating racks with self-cleaning zebrafish tanks. Commercially available systems are costly, and compatibility of intercompany products has never been investigated. Although various cost-effective designs and methods of construction of custom-made recirculating zebrafish racks are available in literature, the design of self-cleaning zebrafish tanks is still not available. In this study, we report the design and method of construction of the self-cleaning unit, which can be fitted in any zebrafish tank. We validated the design by investigating sediment cleaning process in rectangular and cylindrical tank geometries using time lapse imaging. Our results suggest that for both tank geometries, the tanks fitted with self-cleaning unit provided superior sediment cleaning than the tanks fitted with overflow-drain unit. Although the self-cleaning unit could clean the sediment completely from both geometries over prolonged period, the cleaning of sediments was faster in the cylindrical tank than the rectangular tank. In conclusion, cost and efforts of zebrafish maintenance could be significantly reduced through the installation of our self-cleaning unit in any custom-made zebrafish tank.

  5. Evaluation of commercially available aqueous batch immersion cleaning products. Technical report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bevilacqua, P.; Clark, K.G.

    1996-01-10

    With the production of Class I Ozone Depleting Substances scheduled to cease in January 1996, it has become necessary to identify suitable replacements for chlorofluorocarbon (CFC-113, Freon 113) vapor degreasing operations currently used to clean avionics components in Navy aircraft maintenance facilities. In this study, one potential option, the use of aqueous cleaning agents, was explored. Commercially available industrial aqueous cleaning agents were evaluated for cleaning capability on simulated operational soils and effects on aircraft materials. Two cleaning agents, Armakleen 2001 and Crest ABS 901, were recommended as a result of this work, and a Military Specification was drafted outliningmore » performance requirements.« less

  6. The Iowa Disinfection Cleaning Project: Opportunities, Successes, and Challenges of a Structured Intervention Program in 56 Hospitals.

    PubMed

    Carling, Philip; Herwaldt, Loreen A

    2017-08-01

    OBJECTIVE A diverse group of hospitals in Iowa implemented a program to objectively evaluate and improve the thoroughness of disinfection cleaning of near-patient surfaces. Administrative benefits of, challenges of, and impediments to the program were also evaluated. METHODS We conducted a prospective, quasi-experimental pre-/postintervention trial to improve the thoroughness of terminal room disinfection cleaning. Infection preventionists utilized an objective cleaning performance monitoring system (DAZO) to evaluate the thoroughness of disinfection cleaning (TDC) expressed as a proportion of objects confirmed to have been cleaned (numerator) to objects to be cleaned per hospital policy (denominator)×100. Data analysis, educational interventions, and objective performance feedback were modeled on previously published studies using the same monitoring tool. Programmatic analysis utilized unstructured and structured information from participants irrespective of whether they participated in the process improvement aspects to the program. RESULTS Initially, the overall TDC was 61% in 56 hospitals. Hospitals completing 1 or 2 feedback cycles improved their TDC percentages significantly (P90% for at least 38 months. A survey of infection preventionists found that lack of time and staff turnover were the most common reasons for terminating the study early. CONCLUSION The study confirmed that hospitals using this program can improve their TDC percentages significantly. Hospitals must invest resources to improve cleaning and to sustain their gains. Infect Control Hosp Epidemiol 2017;38:960-965.

  7. Cleaning efficacy of hydroxypropyl-beta-cyclodextrin for biofouling reduction on reverse osmosis membranes.

    PubMed

    Alayande, Abayomi Babatunde; Kim, Lan Hee; Kim, In S

    2016-01-01

    In this study, an environmentally friendly compound, hydroxypropyl-beta-cyclodextrin (HP-β-CD) was applied to clean reverse osmosis (RO) membranes fouled by microorganisms. The cleaning with HP-β-CD removed the biofilm and resulted in a flux recovery ratio (FRR) of 102%. As cleaning efficiency is sometimes difficult to determine using flux recovery data alone, attached bacterial cells and extracellular polymeric substances (EPS) were quantified after cleaning the biofouled membrane with HP-β-CD. Membrane surface characterization using scanning electron microscopy (SEM), attenuated total reflectance Fourier transform infrared (ATR-FTIR) and atomic force microscopy (AFM) confirmed the effectiveness of HP-β-CD in removal of biofilm from the RO membrane surface. Finally, a comparative study was performed to investigate the competitiveness of HP-β-CD with other known cleaning agents such as sodium dodecyl sulfate (SDS), ethylenediaminetetraacetic acid (EDTA), Tween 20, rhamnolipid, nisin, and surfactin. In all cases, HP-β-CD was superior.

  8. Hard surface biocontrol in hospitals using microbial-based cleaning products.

    PubMed

    Vandini, Alberta; Temmerman, Robin; Frabetti, Alessia; Caselli, Elisabetta; Antonioli, Paola; Balboni, Pier Giorgio; Platano, Daniela; Branchini, Alessio; Mazzacane, Sante

    2014-01-01

    Healthcare-Associated Infections (HAIs) are one of the most frequent complications occurring in healthcare facilities. Contaminated environmental surfaces provide an important potential source for transmission of many healthcare-associated pathogens, thus indicating the need for new and sustainable strategies. This study aims to evaluate the effect of a novel cleaning procedure based on the mechanism of biocontrol, on the presence and survival of several microorganisms responsible for HAIs (i.e. coliforms, Staphyloccus aureus, Clostridium difficile, and Candida albicans) on hard surfaces in a hospital setting. The effect of microbial cleaning, containing spores of food grade Bacillus subtilis, Bacillus pumilus and Bacillus megaterium, in comparison with conventional cleaning protocols, was evaluated for 24 weeks in three independent hospitals (one in Belgium and two in Italy) and approximately 20000 microbial surface samples were collected. Microbial cleaning, as part of the daily cleaning protocol, resulted in a reduction of HAI-related pathogens by 50 to 89%. This effect was achieved after 3-4 weeks and the reduction in the pathogen load was stable over time. Moreover, by using microbial or conventional cleaning alternatively, we found that this effect was directly related to the new procedure, as indicated by the raise in CFU/m2 when microbial cleaning was replaced by the conventional procedure. Although many questions remain regarding the actual mechanisms involved, this study demonstrates that microbial cleaning is a more effective and sustainable alternative to chemical cleaning and non-specific disinfection in healthcare facilities. This study indicates microbial cleaning as an effective strategy in continuously lowering the number of HAI-related microorganisms on surfaces. The first indications on the actual level of HAIs in the trial hospitals monitored on a continuous basis are very promising, and may pave the way for a novel and cost-effective strategy to counteract or (bio)control healthcare-associated pathogens.

  9. Hard Surface Biocontrol in Hospitals Using Microbial-Based Cleaning Products

    PubMed Central

    Vandini, Alberta; Temmerman, Robin; Frabetti, Alessia; Caselli, Elisabetta; Antonioli, Paola; Balboni, Pier Giorgio; Platano, Daniela; Branchini, Alessio; Mazzacane, Sante

    2014-01-01

    Background Healthcare-Associated Infections (HAIs) are one of the most frequent complications occurring in healthcare facilities. Contaminated environmental surfaces provide an important potential source for transmission of many healthcare-associated pathogens, thus indicating the need for new and sustainable strategies. Aim This study aims to evaluate the effect of a novel cleaning procedure based on the mechanism of biocontrol, on the presence and survival of several microorganisms responsible for HAIs (i.e. coliforms, Staphyloccus aureus, Clostridium difficile, and Candida albicans) on hard surfaces in a hospital setting. Methods The effect of microbial cleaning, containing spores of food grade Bacillus subtilis, Bacillus pumilus and Bacillus megaterium, in comparison with conventional cleaning protocols, was evaluated for 24 weeks in three independent hospitals (one in Belgium and two in Italy) and approximately 20000 microbial surface samples were collected. Results Microbial cleaning, as part of the daily cleaning protocol, resulted in a reduction of HAI-related pathogens by 50 to 89%. This effect was achieved after 3–4 weeks and the reduction in the pathogen load was stable over time. Moreover, by using microbial or conventional cleaning alternatively, we found that this effect was directly related to the new procedure, as indicated by the raise in CFU/m2 when microbial cleaning was replaced by the conventional procedure. Although many questions remain regarding the actual mechanisms involved, this study demonstrates that microbial cleaning is a more effective and sustainable alternative to chemical cleaning and non-specific disinfection in healthcare facilities. Conclusions This study indicates microbial cleaning as an effective strategy in continuously lowering the number of HAI-related microorganisms on surfaces. The first indications on the actual level of HAIs in the trial hospitals monitored on a continuous basis are very promising, and may pave the way for a novel and cost-effective strategy to counteract or (bio)control healthcare-associated pathogens. PMID:25259528

  10. An assessment of cleaning and sampling methods for food-contact surfaces in premises preparing and selling high-risk foods.

    PubMed Central

    Tebbutt, G. M.

    1991-01-01

    The performance of agar-contact plates and an alginate-swab method for sampling food surfaces before and after cleaning was compared. Contact plates were more convenient, and were at least as sensitive as the swabbing method. To assess cleaning efficiency repeated sampling was carried out in selected premises, and several cleaning methods were introduced for trial periods. Some surfaces, notably wood and polypropylene, were particularly difficult to clean. For these scrubbing with a nylon brush was the best method. Other surfaces were more easily cleaned, and generally the methods introduced as part of this study were better than the original method used in the premises. Paper proved to be unpopular, and cleaning solutions applied with it did no better than those cleaned with a multiuse cloth kept soaking in a detergent and hypochlorite solution. PMID:1850362

  11. Cavitation effects in ultrasonic cleaning baths

    NASA Technical Reports Server (NTRS)

    Glasscock, Barbara H.

    1995-01-01

    In this project, the effect of cavitation from aqueous ultrasonic cleaning on the surfaces of metal and non-metal sample coupons was studied. After twenty cleaning cycles, the mass loss from the aluminum coupons averaged 0.22 mg/sq cm surface area and 0.014 mg/sq cm for both stainless steel and titanium. The aluminum coupons showed visual evidence of minor cavitation erosion in regions of previously existing surface irregularities. The non-metal samples showed some periods of mass gain. These effects are believed to have minor impact on hardware being cleaned, but should be evaluated in the context of specific hardware requirements. Also the ultrasonic activity in the large cleaning baths was found to be unevenly distributed as measured by damage to sheets of aluminum foil. It is therefore recommended that items being cleaned in an ultrasonic bath be moved or conveyed during the cleaning to more evenly distribute the cavitation action provide more uniform cleaning.

  12. Storage and utilization patterns of cleaning products in the home: toxicity implications.

    PubMed

    Sawalha, Ansam F

    2007-11-01

    Cleaning products are used to achieve cleaner homes. However, they have been responsible for a considerable number of poisoning cases. The aims of this study were to investigate the storage and utilization patterns of cleaning products in the home, as well as the risk of adverse and toxic effects produced by them. This study has been performed using a questionnaire that was developed by the Poison Control and Drug Information Center (PCDIC). The questionnaire was distributed randomly in northern Palestine. The questionnaire included questions regarding storage, utilization habits, and the adverse effects experienced by respondents upon handling the cleaning products. All respondents utilized and stored cleaning products in their homes. Chlorine bleach and acidic cleaning products were the most common. Respondents stored cleaning products at different places in their homes, but most of those storage places were suboptimal and were within the reach of children. The daily utilization rate of cleaning products was 1.6+/-0.8 with chlorine bleach being the most commonly used. Of the respondents, 27% reported experiencing a wide range of acute adverse and toxic effects resulting from cleaning product use and that exposure occurred mainly via inhalation. Caustic substances, bleach, and kerosene were the agents mainly involved in producing these adverse and toxic effects. About half of those who experienced adverse and toxic effects sought medical help, and 22% of them were children younger than 6 years of age. Finally, most respondents reported mixing and discarding cleaning product leftovers and their containers improperly. Correct utilization and safer storage of cleaning products is encouraged. Several preventive strategies should be implemented in order to decrease the incidence of accidental harmful exposure that is due to cleaning agents. The role of the PCDIC is very important in the education, prevention, and management of cleaning product-induced adverse effects.

  13. A fine coal circuitry study using column flotation and gravity separation. Quarterly report, 1 March 1995--31 May 1995

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Honaker, R.Q.; Reed, S.

    1995-12-31

    Column flotation provides excellent recovery of ultrafine coal while producing low ash content concentrates. However, column flotation is not efficient for treating fine coal containing significant amounts of mixed-phase particles. Fortunately, enhanced gravity separation has proved to have the ability to treat the mixed-phased particles more effectively. A disadvantage of gravity separation is that ultrafine clay particles are not easily rejected. Thus, a combination of these two technologies may provide a circuit that maximizes both the ash and sulfur rejection that can be achieved by physical coal cleaning while maintaining a high energy recovery. This project is studying the potentialmore » of using different combinations of gravity separators, i.e., a Floatex hydrosizer and a Falcon Concentrator, and a proven flotation column, which will be selected based on previous studies by the principle investigator. During this reporting period, an extensive separation performance comparison between a pilot-scale Floatex Density Separator (18{times}18-inch) and an existing spiral circuit has been conducted at Kerf-McGee Coal Preparation plan for the treatment of nominally {minus}16 mesh coal. The results indicate that the Floatex is a more efficient separation device (E{sub p}=0.12) than a conventional coal spiral (E{sub p}=0.18) for Illinois seam coals. In addition, the treatment of {minus}100 mesh Illinois No. 5 fine coal from the same plant using Falcon concentrator, column flotation (Packed-Column) and their different combinations was also evaluated. For a single operation, both Falcon concentrator and column flotation can produce a clean coal product with 90% combustible recovery and 5% ash content. In the case of the combined circuit, column flotation followed by the Falcon achieved a higher combustible recovery value (about 75%) than that obtained by the individual units while maintaining an ash content less than 3%.« less

  14. DOE Office of Scientific and Technical Information (OSTI.GOV)

    M. R. Doshi; J. Dyer

    Laboratory research indicates that wax is amenable to removal by froth flotation provided it is free or detached from the fiber. The only effective means, at this time, of maximizing detachment of wax is through the use of low consistency pulping at temperatures above the melting point of wax. Wax removal from WCC through washing, flotation, or a combination of both was approximately 90% in these laboratory studies, indicating that not all of the wax is detached from fibers. These results were summarized in Annual Report 1, December 1, 1997 to November 30, 1998. Pilot trials were conducted in whichmore » the authors simulated a conventional OCC repulping process with and without flotation. Additional aggressive washing and water clarification were also examined during the study. The inclusion of flotation in the OCC stock preparation system significantly improved the removal of wax spots and extractable material from the furnish. Based on this study, the authors predict that a compact flotation system with 2 lb surfactant/ton of fiber would improve the OCC pulp quality with regard to wax spots by 60% and would not negatively affect strength properties. Flotation losses would be in the 2-5% range. Two mill trials were conducted during the last quarter of the project. One trial was carried out at Green Bay Packaging, Green Bay, WI, and a second trial was conducted at Menasha Corporation, Otsego, MI. A 250-liter Voith Sulzer Ecocell was used to evaluate the removal of wax and stickies from the OCC processing systems at these two mills. The inclusion of flotation in the OCC stock preparation system significantly improved the removal of wax spots from the furnish. The data indicate that flotation was more effective in removing wax and stickies than reverse cleaners. The mill trials have demonstrated that flotation can be substituted for or replace existing reverse cleaning systems and, in some cases, can replace dispersion systems. In this manner, the use of flotation can provide significant energy savings when compared to reverse cleaning or dispersion.« less

  15. NHEXAS PHASE I ARIZONA STUDY--STANDARD OPERATING PROCEDURE FOR STANDARD PROTOCOL FOR CLEANING LABORATORY AND FIELD SAMPLING APPARATUS (UA-L-5.1)

    EPA Science Inventory

    The purpose of this SOP is to describe the standard approach used for cleaning glassware and plasticware during the Arizona NHEXAS project and the "Border" study. Keywords: lab; equipment; cleaning.

    The National Human Exposure Assessment Survey (NHEXAS) is a federal interagency...

  16. NHEXAS PHASE I ARIZONA STUDY--STANDARD OPERATING PROCEDURE FOR CLEANING: 24 HOUR FOOD DIARY (HAND ENTRY) (UA-D-40.0)

    EPA Science Inventory

    The purpose of the SOP is to define the particular steps involved in cleaning the electronic data generated from data entry of the 24 Hour Food Diary. The procedure was developed to use during the Arizona NHEXAS project and the "Border" study. Keywords: data; cleaning; 24 hour ...

  17. Why undertake a pilot in a qualitative PhD study? Lessons learned to promote success.

    PubMed

    Wray, Jane; Archibong, Uduak; Walton, Sean

    2017-01-23

    Background Pilot studies can play an important role in qualitative studies. Methodological and practical issues can be shaped and refined by undertaking pilots. Personal development and researchers' competence are enhanced and lessons learned can inform the development and quality of the main study. However, pilot studies are rarely published, despite their potential to improve knowledge and understanding of the research. Aim To present the main lessons learned from undertaking a pilot in a qualitative PhD study. Discussion This paper draws together lessons learned when undertaking a pilot as part of a qualitative research project. Important methodological and practical issues identified during the pilot study are discussed including access, recruitment, data collection and the personal development of the researcher. The resulting changes to the final study are also highlighted. Conclusion Sharing experiences of and lessons learned in a pilot study enhances personal development, improves researchers' confidence and competence, and contributes to the understanding of research. Implications for practice Pilots can be used effectively in qualitative studies to refine the final design, and provide the researcher with practical experience to enhance confidence and competence.

  18. Formulation of low solids coal water slurry from advanced coal cleaning waste fines

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Battista, J.J.; Morrison, J.L.; Lambert, A.

    1997-07-01

    GPU Genco, the New York State Electric and Gas Corporation (NYSEG), Penn State University and the Homer City Coal Processing Corporation are conducting characterization and formulation tests to determine the suitability of using minus 325 mesh coal waste fines as a low solids coal water slurry (CWS) co-firing fuel. The fine coal is contained in a centrifuge effluent stream at the recently modified Homer City Coal Preparation Plant. Recovering, thickening and then co-firing this material with pulverized coal is one means of alleviating a disposal problem and increasing the Btu recovery for the adjacent power plant. The project team ismore » currently proceeding with the design of a pilot scale system to formulate the effluent into a satisfactory co-firing fuel on a continuous basis for combustion testing at Seward Station. The ultimate goal is to burn the fuel at the pulverized coal units at the Homer City Generating Station. This paper presents the success to date of the slurry characterization and pilot scale design work. In addition, the paper will update GPU Genco`s current status for the low solids coal water slurry co-firing technology and will outline the company`s future plans for the technology.« less

  19. Performance of a pilot showcase of different wetland systems in an urban setting in Singapore.

    PubMed

    Quek, B S; He, Q H; Sim, C H

    2015-01-01

    The Alexandra Wetlands, part of PUB's Active, Beautiful, Clean Waters (ABC Waters) Programme, showcase a surface flow wetland, an aquatic pond and a sub-surface flow wetland on a 200 m deck built over an urban drainage canal. Water from the canal is pumped to a sedimentation basin, before flowing in parallel to the three wetlands. Water quality monitoring was carried out monthly from April 2011 to December 2012. The order of removal efficiency is sub-surface flow (81.3%) >aquatic pond (58.5%) >surface flow (50.7%) for total suspended solids (TSS); sub-surface (44.9%) >surface flow (31.9%) >aquatic pond (22.0%) for total nitrogen (TN); and surface flow (56.7%) >aquatic pond (39.8%) >sub-surface flow (5.4%) for total phosphorus (TP). All three wetlands achieved the Singapore stormwater treatment objectives (STO) for TP removal, but only the sub-surface flow wetland met the STO for TSS, and none met the STO for TN. Challenges in achieving satisfactory performance include inconsistent feed water quality, undesirable behaviour such as fishing, release of pets and feeding of animals in the wetlands, and canal dredging during part of the monitoring period. As a pilot showcase, the Alexandra Wetlands provide useful lessons for implementing multi-objective wetlands in an urban setting.

  20. Inspiring Climate Education Excellence (ICEE): Developing self-directed professional development modules for secondary science teachers

    NASA Astrophysics Data System (ADS)

    Buhr, S. M.; Lynds, S. E.; McCaffrey, M. S.; Morton, E.

    2010-12-01

    Inspiring Climate Education Excellence (ICEE) is a NASA-funded project to develop online course modules and self-directed learning resources aligned with the Essential Principles of Climate Science. Following a national needs assessment survey and a face to face workshop to pilot test topics, a suite of online modules is being developed suitable for self-directed learning by secondary science teachers. Modules are designed around concepts and topics in which teachers express the most interest and need for instruction. Module design also includes attention to effective teaching strategies, such as awareness of student misconceptions, strategies for forestalling controversy and advice from master teachers on implementation and curriculum development. The resources are being developed in partnership with GLOBE, and the National Science Digital Library (NSDL) and is informed by the work of the Climate Literacy and Energy Awareness Network (CLEAN) project. ICEE will help to meet the professional development needs of teachers, including those participating in the GLOBE Student Climate Research Campaign. Modules and self-directed learning resources will be developed and disseminated in partnership with the National Science Digital Library (NSDL). This presentation introduces the needs assessment and pilot workshop data upon which the modules are based, and describes the modules that are available and in development.

  1. Comparative study between chemical and atmospheric pressure plasma jet cleaning on glass substrate

    NASA Astrophysics Data System (ADS)

    Elfa, Rizan Rizon; Ahmad, Mohd Khairul; Fhong, Soon Chin; Sahdan, Mohd Zainizan; Nayan, Nafarizal

    2017-01-01

    The atmospheric pressure plasma jet with low frequency and argon as working gas is presented in this paper to demonstrate its application for glass substrate clean and modification. The glass substrate clean by atmospheric pressure plasma jet is an efficient method to replace other substrate clean method. A comparative analysis is done in this paper between substrate cleaned by chemical and plasma treatment methods. Water contact angle reading is taken for a different method of substrate clean and period of treatment. Under the plasma treatment, the sample shows low surface adhesion due to having the surface property of super hydrophilic surface 7.26°. This comparative analysis is necessary in the industrial application for cost production due to sufficient time and method of substrate clean.

  2. Alternative Chemical Cleaning Methods for High Level Waste Tanks: Simulant Studies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rudisill, T.; King, W.; Hay, M.

    Solubility testing with simulated High Level Waste tank heel solids has been conducted in order to evaluate two alternative chemical cleaning technologies for the dissolution of sludge residuals remaining in the tanks after the exhaustion of mechanical cleaning and sludge washing efforts. Tests were conducted with non-radioactive pure phase metal reagents, binary mixtures of reagents, and a Savannah River Site PUREX heel simulant to determine the effectiveness of an optimized, dilute oxalic/nitric acid cleaning reagent and pure, dilute nitric acid toward dissolving the bulk non-radioactive waste components. A focus of this testing was on minimization of oxalic acid additions duringmore » tank cleaning. For comparison purposes, separate samples were also contacted with pure, concentrated oxalic acid which is the current baseline chemical cleaning reagent. In a separate study, solubility tests were conducted with radioactive tank heel simulants using acidic and caustic permanganate-based methods focused on the “targeted” dissolution of actinide species known to be drivers for Savannah River Site tank closure Performance Assessments. Permanganate-based cleaning methods were evaluated prior to and after oxalic acid contact.« less

  3. CLEAN-ROADS project: air quality considerations after the application of a novel MDSS on winter road maintenance activities

    NASA Astrophysics Data System (ADS)

    Pretto, Ilaria; Malloci, Elisa; Tonidandel, Gabriele; Benedetti, Guido; Di Napoli, Claudia; Piazza, Andrea; Apolloni, Roberto; Cavaliere, Roberto

    2016-04-01

    With this poster we present the environmental benefit on air quality derived by the application of the CLEAN-ROADS pilot project. The CLEAN-ROADS project addresses the problem of the environmental pollution caused by de-icing salts during winter road maintenance activities in the Province of Trento (Italy). A demonstrative Maintenance Decision Support System (MDSS) has been developed in order to improve the intervention procedures of the road management service. Specifically it aims to optimize the efficiency of how available resources (e.g., salt consumption) are currently used while guaranteeing the current level of road safety. The CLEAN-ROADS project has been tested and validated on a test area located in a valley bottom (Adige Valley), where the highest optimization margins are to be expected. The project supports current road maintenance practices, which has proved to be reliable and accurate, with a new scalable and energy-efficient road monitoring system. This system is based on a network of road weather stations (road weather information system, RWIS) installed on the test route. It is capable to collect real-time data about the road conditions and to perform short-term and now-cast road weather forecasts, which actively integrate weather data and bulletins covering the target area [1]. This poster presents the results obtained from a three-year monitoring activity with the aim to (1) determine the impact of de-icing salts on air quality and (2) quantify the improvements obtained by the application of the CLEAN-ROADS project on air quality. The Ambient Air Quality and Cleaner Air for Europe Directive (2008/50/EC) states that contributions to exceedances of particulate matter PM10 limit values that are attributable to road winter salting may be subtracted when assessing compliance with air quality limit values, once provided that reasonable measures have been taken to lower concentrations [2]. As the de-icing salts used in road maintenance are mainly based on sodium chloride, which releases Na+ and Cl-, the estimation of the contribution of road salting to PM10 concentration can be carried out considering only measured concentrations of Na+ and Cl-. However, the presence of these elements might not be due exclusively to salting activities. For this reason data collected during first winter campaign were analysed using the Positive Matrix Factorization (PMF) Model developed by United States Environmental Protection Agency (EPA) to identify the presence of Na+ and Cl- in emission profiles of other PM10 sources (e.g., biomass burning, traffic) [3]. Through this study new guidelines have been defined for the optimization of current road management operations, and their applicability to other area in the Province of Trento has been assessed for future purposes. [1] Pretto I. et al., SIRWEC 2014 conference proceedings, ID:0019 (2014) [2] Ambient Air Quality and Cleaner Air for Europe (CAFE) Directive (2008/50/EC) [3] http://www.epa.gov/air-research/positive-matrix-factorization-model-environmental-data-analyses

  4. The Use of Household Cleaning Sprays and Adult Asthma

    PubMed Central

    Zock, Jan-Paul; Plana, Estel; Jarvis, Deborah; Antó, Josep M.; Kromhout, Hans; Kennedy, Susan M.; Künzli, Nino; Villani, Simona; Olivieri, Mario; Torén, Kjell; Radon, Katja; Sunyer, Jordi; Dahlman-Hoglund, Anna; Norbäck, Dan; Kogevinas, Manolis

    2007-01-01

    Rationale: Cleaning work and professional use of certain cleaning products have been associated with asthma, but respiratory effects of nonprofessional home cleaning have rarely been studied. Objectives: To investigate the risk of new-onset asthma in relation to the use of common household cleaners. Methods: Within the follow-up of the European Community Respiratory Health Survey in 10 countries, we identified 3,503 persons doing the cleaning in their homes and who were free of asthma at baseline. Frequency of use of 15 types of cleaning products was obtained in a face-to-face interview at follow-up. We studied the incidence of asthma defined as physician diagnosis and as symptoms or medication usage at follow-up. Associations between asthma and the use of cleaning products were evaluated using multivariable Cox proportional hazards or log-binomial regression analysis. Measurements and Main Results: The use of cleaning sprays at least weekly (42% of participants) was associated with the incidence of asthma symptoms or medication (relative risk [RR], 1.49; 95% confidence interval [CI], 1.12−1.99) and wheeze (RR, 1.39; 95% CI, 1.06−1.80). The incidence of physician-diagnosed asthma was higher among those using sprays at least 4 days per week (RR, 2.11; 95% CI, 1.15−3.89). These associations were consistent for subgroups and not modified by atopy. Dose–response relationships (P < 0.05) were apparent for the frequency of use and the number of different sprays. Risks were predominantly found for the commonly used glass-cleaning, furniture, and air-refreshing sprays. Cleaning products not applied in spray form were not associated with asthma. Conclusions: Frequent use of common household cleaning sprays may be an important risk factor for adult asthma. PMID:17585104

  5. Exposure of German residents to ethylene and propylene glycol ethers in general and after cleaning scenarios.

    PubMed

    Fromme, H; Nitschke, L; Boehmer, S; Kiranoglu, M; Göen, T

    2013-03-01

    Glycol ethers are a class of semi-volatile substances used as solvents in a variety of consumer products like cleaning agents, paints, cosmetics as well as chemical intermediates. We determined 11 metabolites of ethylene and propylene glycol ethers in 44 urine samples of German residents (background level study) and in urine samples of individuals after exposure to glycol ethers during cleaning activities (exposure study). In the study on the background exposure, methoxyacetic acid and phenoxyacetic acid (PhAA) could be detected in each urine sample with median (95th percentile) values of 0.11 mgL(-1) (0.30 mgL(-1)) and 0.80 mgL(-1) (23.6 mgL(-1)), respectively. The other metabolites were found in a limited number of samples or in none. In the exposure study, 5-8 rooms were cleaned with a cleaner containing ethylene glycol monobutyl ether (EGBE), propylene glycol monobutyl ether (PGBE), or ethylene glycol monopropyl ether (EGPE). During cleaning the mean levels in the indoor air were 7.5 mgm(-3) (EGBE), 3.0 mgm(-3) (PGBE), and 3.3 mgm(-3) (EGPE), respectively. The related metabolite levels analysed in the urine of the residents of the rooms at the day of cleaning were 2.4 mgL(-1) for butoxyacetic acid, 0.06 mgL(-1) for 2-butoxypropionic acid, and 2.3 mgL(-1) for n-propoxyacetic acid. Overall, our study indicates that the exposure of the population to glycol ethers is generally low, with the exception of PhAA. Moreover, the results of the cleaning scenarios demonstrate that the use of indoor cleaning agents containing glycol ethers can lead to a detectable internal exposure of residents. Copyright © 2012 Elsevier Ltd. All rights reserved.

  6. Reduction of risk of Salmonella infection from kitchen cleaning clothes by use of sodium hypochlorite disinfectant cleaner.

    PubMed

    Chaidez, C; Soto-Beltran, M; Gerba, C P; Tamimi, A H

    2014-11-01

    The objective of this study was to evaluate the reduction of infection risk due to exposure to Salmonella sp. in kitchen cleaning clothes by the use of a bleach (sodium hypochlorite) cleaner utilizing a continuous-time dynamic exposure model. The only route of exposure considered was hand contamination during cloth use. The occurrence and numbers of Salmonella was studied in 60 homes over a 6-week period in which half disinfected kitchen cleaning clothes with a sodium hypochlorite based disinfectant cleaner. This study demonstrated that a significant risk exists for Salmonella infection from kitchen cleaning clothes in Mexican homes and that this risk can be reduced by almost 100-fold by soaking cleaning clothes in a bleach product. The risks of infection and illness could likely be further reduced by developing a more effective procedure for reducing Salmonella in cleaning clothes treated twice a day with a sodium hypochlorite disinfectant (i.e. longer soaking time) or using a greater concentration of the disinfectant. Hygiene intervention is a key strategy to reduce the potential risk of disease-causing micro-organisms in households. There is a lack of understanding of the human health risk associated with the use of contaminated kitchen cleaning cloths. The study used a quantitative microbial risk assessment to estimate the risk associated with the use of kitchen cleaning clothes by using disinfectant products. The results showed that the use of prescribe protocols can reduce the risk of Salmonella infections in household kitchens. © 2014 The Society for Applied Microbiology.

  7. EMISSIONS OF PERCHLOROETHYLENE FROM DRY CLEANED FABRICS

    EPA Science Inventory

    A study was conducted to evaluate the emissions of perchloroethylene (tetrachloroethylene) from dry cleaned fabrics to determine: (a) how the introduction of fresh dry cleaning into a home affects the indoor concentration of perchloroethylene, and (b) the effectiveness of ‘airing...

  8. U.S.-MEXICO BORDER PROGRAM ARIZONA BORDER STUDY--STANDARD OPERATING PROCEDURE FOR STANDARD PROTOCOL FOR CLEANING LABORATORY AND FIELD SAMPLING APPARATUS (UA-L-5.1)

    EPA Science Inventory

    The purpose of this SOP is to describe the standard approach used for cleaning glassware and plasticware during the Arizona NHEXAS project and the Border study. Keywords: lab; equipment; cleaning.

    The U.S.-Mexico Border Program is sponsored by the Environmental Health Workgroup...

  9. On-farm comparisons of different cleaning protocols in broiler houses.

    PubMed

    Luyckx, K Y; Van Weyenberg, S; Dewulf, J; Herman, L; Zoons, J; Vervaet, E; Heyndrickx, M; De Reu, K

    2015-08-01

    The present study evaluated the effectiveness of 4 cleaning protocols designed to reduce the bacteriological infection pressure on broiler farms and prevent food-borne zoonoses. Additionally, difficult to clean locations and possible sources of infection were identified. Cleaning and disinfection rounds were evaluated in 12 broiler houses on 5 farms through microbiological analyses and adenosine triphosphate hygiene monitoring. Samples were taken at 3 different times: before cleaning, after cleaning, and after disinfection. At each sampling time, swabs were taken from various locations for enumeration of the total aerobic flora and Enterococcus species pluralis ( SPP:). In addition, before cleaning and after disinfection, testing for Escherichia coli and Salmonella was carried out. Finally, adenosine triphosphate swabs and agar contact plates for total aerobic flora counts were taken after cleaning and disinfection, respectively. Total aerobic flora and Enterococcus spp. counts on the swab samples showed that cleaning protocols which were preceded by an overnight soaking with water caused a higher bacterial reduction compared to protocols without a preceding soaking step. Moreover, soaking of broiler houses leads to less water consumption and reduced working time during high pressure cleaning. No differences were found between protocols using cold or warm water during cleaning. Drinking cups, drain holes, and floor cracks were identified as critical locations for cleaning and disinfection in broiler houses. © 2015 Poultry Science Association Inc.

  10. Following ergonomics guidelines decreases physical and cardiovascular workload during cleaning tasks.

    PubMed

    Samani, Afshin; Holtermann, Andreas; Søgaard, Karen; Holtermann, Andreas; Madeleine, Pascal

    2012-01-01

    The aim was to investigate the effect of ergonomics guidelines on muscular activity, postural and cardiovascular load during cleaning. Eighteen cleaners performed 10 min of cleaning tasks in two locations; three min in a laboratory and seven min in a lecture room. All participants performed the task with or without focusing on ergonomics guidelines (ergonomics/non-ergonomics session). Bipolar surface electromyography was recorded bilaterally from upper trapezius and erector spinae muscles. A tri-axial accelerometer package was mounted on the low back (L5-S1) to measure postural changes, and the cardiovascular load was estimated by electrocardiogram. Ergonomics sessions resulted in lower muscular load, a more complex pattern of muscular activity, lower range of motion and angular velocity of the trunk as well as lower cardiovascular load compared with non-ergonomics sessions (p < 0.05). The study highlighted the multiple musculoskeletal and cardiovascular benefits of following ergonomics guidelines during cleaning tasks. This study investigated the effects of following instructive ergonomics guidelines during cleaning tasks (daily curriculum of cleaning including mopping, sweeping, changing trash bins and cleaning of desks and blackboards). Following the ergonomics guidelines reduces the general workload and induces a more complex pattern of muscular activity. The study contributes with novel knowledge concerning ergonomics guidelines and work techniques.

  11. The Effects of Longitudinal Control-System Dynamics on Pilot Opinion and Response Characteristics as Determined from Flight Tests and from Ground Simulator Studies

    NASA Technical Reports Server (NTRS)

    Sadoff, Melvin

    1958-01-01

    The results of a fixed-base simulator study of the effects of variable longitudinal control-system dynamics on pilot opinion are presented and compared with flight-test data. The control-system variables considered in this investigation included stick force per g, time constant, and dead-band, or stabilizer breakout force. In general, the fairly good correlation between flight and simulator results for two pilots demonstrates the validity of fixed-base simulator studies which are designed to complement and supplement flight studies and serve as a guide in control-system preliminary design. However, in the investigation of certain problem areas (e.g., sensitive control-system configurations associated with pilot- induced oscillations in flight), fixed-base simulator results did not predict the occurrence of an instability, although the pilots noted the system was extremely sensitive and unsatisfactory. If it is desired to predict pilot-induced-oscillation tendencies, tests in moving-base simulators may be required. It was found possible to represent the human pilot by a linear pilot analog for the tracking task assumed in the present study. The criterion used to adjust the pilot analog was the root-mean-square tracking error of one of the human pilots on the fixed-base simulator. Matching the tracking error of the pilot analog to that of the human pilot gave an approximation to the variation of human-pilot behavior over a range of control-system dynamics. Results of the pilot-analog study indicated that both for optimized control-system dynamics (for poor airplane dynamics) and for a region of good airplane dynamics, the pilot response characteristics are approximately the same.

  12. 76 FR 70152 - Pilot Program for Early Feasibility Study Investigational Device Exemption Applications

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-11-10

    ...] Pilot Program for Early Feasibility Study Investigational Device Exemption Applications AGENCY: Food and... feasibility study investigational device exemption (IDE) applications. The pilot program will conform to the... Feasibility Medical Device Clinical Studies, Including Certain First in Human (FIH) Studies.'' Under the pilot...

  13. Cleaning interactions by gobies on a tropical eastern Pacific coral reef.

    PubMed

    Quimbayo, J P; Zapata, F A

    2018-04-01

    The present study describes the cleaning interactions among species of cleaner gobies Tigrigobius spp. and Elacatinus puncticulatus (family Gobiidae) and the client fish species they clean in a coral reef of Gorgona Island, Colombia. In 419 cleaning events, we observed 27 species acting as clients of Tigrigobius spp., whereas only nine were clients of E. puncticulatus. Paranthias colonus and Cephalopholis panamensis were the species most commonly cleaned by Tigrigobius spp., while Ophioblennius steindachneri and Stegastes acalpulcoensis were the clients most commonly cleaned by E. puncticulatus. The abundance (but not the body size) of clients was an important variable predicting the cleaning frequency observed for clients of Tigrigobius spp., but this was not the case for clients of E. puncticulatus. Additionally, Tigrigobius spp. preferred cleaning planktivores, sessile invertebrate feeders and territorial herbivores (Ivlev's index >0·15), whereas E. puncticulatus did not exhibit any preference. We observed two major peaks of cleaning activity for Tigrigobius spp., one in the early morning and another one in the late afternoon. These results suggest that Tigrigobius spp. is a specialized cleaner goby, whereas E. puncticulatus is a facultative cleaner that cleans sporadically. © 2018 The Fisheries Society of the British Isles.

  14. An international survey of cleaning and disinfection practices in the healthcare environment.

    PubMed

    Kenters, N; Gottlieb, T; Hopman, J; Mehtar, S; Schweizer, M L; Tartari, E; Huijskens, E G W; Voss, A

    2018-06-18

    Antimicrobial resistance has become an urgent global health priority. Basic hygiene practices and cleaning and disinfection of the hospital environment are key in preventing pathogen cross-transmission. To our knowledge no studies have assessed the worldwide differences in cleaning and disinfection practices in healthcare facilities. The electronic survey described here was developed in order to evaluate differences in healthcare facility cleaning practices around the world. The International Society of Antimicrobial Chemotherapy (ISAC, formerly ISC), Infection Prevention and Control work group developed a survey with 30 multiple-choice questions. The questions were designed to assess the current cleaning practices in healthcare settings around the world. A total of 110 healthcare professionals, representing 23 countries, participated in the online survey. In 96% of the facilities a written cleaning policy was present. Training of cleaning staff occurred in 70% of the facilities at the start of employment. Cleaning practices and monitoring of these practices varied. The survey enabled assessment and recognition of widely differing global practices in approaches to environmental cleaning and disinfection. Development of guideline recommendations for cleaning and disinfection could improve practices and set minimum standards worldwide. Copyright © 2018 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  15. Evaluating use of neutral electrolyzed water for cleaning near-patient surfaces.

    PubMed

    Stewart, M; Bogusz, A; Hunter, J; Devanny, I; Yip, B; Reid, D; Robertson, C; Dancer, S J

    2014-12-01

    This study aimed to monitor the microbiological effect of cleaning near-patient sites over a 48-hour period with a novel disinfectant, electrolyzed water. One ward dedicated to acute care of the elderly population in a district general hospital in Scotland. Lockers, left and right cotsides, and overbed tables in 30 bed spaces were screened for aerobic colony count (ACC), methicillin-susceptible Staphylococcus aureus (MSSA), and methicillin-resistant S. aureus (MRSA) before cleaning with electrolyzed water. Sites were rescreened at varying intervals from 1 to 48 hours after cleaning. Microbial growth was quantified as colony-forming units (CFUs) per square centimeter and presence or absence of MSSA and MRSA at each site. The study was repeated 3 times at monthly intervals. There was an early and significant reduction in average ACC (360 sampled sites) from a before-cleaning level of 4.3 to 1.65 CFU/cm(2) at 1 hour after disinfectant cleaning ( P < .0001). Average counts then increased to 3.53 CFU/cm(2) at 24 hours and 3.68 CFU/cm(2) at 48 hours. Total MSSA/MRSA (34 isolates) decreased by 71% at 4 hours after cleaning but then increased to 155% (53 isolates) of precleaning levels at 24 hours. Cleaning with electrolyzed water reduced ACC and staphylococci on surfaces beside patients. ACC remained below precleaning levels at 48 hours, but MSSA/MRSA counts exceeded original levels at 24 hours after cleaning. Although disinfectant cleaning quickly reduces bioburden, additional investigation is required to clarify the reasons for rebound contamination of pathogens at near-patient sites.

  16. Effectiveness of Surface Cleaning and Disinfection in a Brazilian Healthcare Facility.

    PubMed

    Santos-Junior, Aires G; Ferreira, Adriano M; Frota, Oleci P; Rigotti, Marcelo A; Barcelos, Larissa da S; Lopes de Sousa, Alvaro Francisco; de Andrade, Denise; Guerra, Odanir G; R Furlan, Mara C

    2018-01-01

    Failures in the processes of cleaning and disinfecting health service surfaces may result in the spread and transfer of pathogens that are often associated with healthcare-related infections and outbreaks. To assess the effectiveness of environmental surface cleaning and disinfection in a hospital clinic. The study was conducted in a nursing ward with 45 beds. A total of 80 samples from five high-touch surfaces were evaluated before and after cleaning and disinfection, using the following methods: visual inspection, adenosine triphosphate bioluminescence assay, aerobic colony count, Staphylococcus aureus colony count, and evaluation of resistance to methicillin. The data analysis used nonparametric comparative and correlative tests to observe any differences in the pre- and post- cleaning and disinfection results for the surfaces assessed. Effective cleaning and disinfection had a significant effect on only two surfaces when measured for the presence of adenosine triphosphate, the inner bathroom door handle ( p =0.007) and the toilet bowl ( p =0.01). When evaluated for Staphylococcus aureus colony count, the toilet flush handle also demonstrated a significant effect ( p =0.04). The effectiveness of cleaning and disinfection of the surfaces tested was not satisfactory. An educational intervention is recommended for the cleaning and disinfection staff and the nursing team at the healthcare facility. The data in the study revealed that daily hospital cleaning and disinfection in the sampled sites are not sufficient in medical and surgical wards. Hospital cleanliness must be reevaluated from the point of view of materials, such as an adequate supply of clean cloths, in addition to establishing more precise cleanliness protocols and accurate monitoring systems.

  17. Impact of backwashing procedures on deep bed filtration productivity in drinking water treatment.

    PubMed

    Slavik, Irene; Jehmlich, Alexander; Uhl, Wolfgang

    2013-10-15

    Backwash procedures for deep bed filters were evaluated and compared by means of a new integrated approach based on productivity. For this, different backwash procedures were experimentally evaluated by using a pilot plant for direct filtration. A standard backwash mode as applied in practice served as a reference and effluent turbidity was used as the criterion for filter run termination. The backwash water volumes needed, duration of the filter-to-waste period, time out of operation, total volume discharged and filter run-time were determined and used to calculate average filtration velocity and average productivity. Results for filter run-times, filter backwash volumes, and filter-to-waste volumes showed considerable differences between the backwash procedures. Thus, backwash procedures with additional clear flushing phases were characterised by an increased need for backwash water. However, this additional water consumption could not be compensated by savings during filter ripening. Compared to the reference backwash procedure, filter run-times were longer for both single-media and dual-media filters when air scour and air/water flush were optimised with respect to flow rates and the proportion of air and water. This means that drinking water production time is longer and less water is needed for filter bed cleaning. Also, backwashing with additional clear flushing phases resulted in longer filter run-times before turbidity breakthrough. However, regarding the productivity of the filtration process, it was shown that it was almost the same for all of the backwash procedures investigated in this study. Due to this unexpected finding, the relationships between filter bed cleaning, filter ripening and filtration performance were considered and important conclusions and new approaches for process optimisation and resource savings were derived. Copyright © 2013 Elsevier Ltd. All rights reserved.

  18. Evaluating a new paradigm for comparing surface disinfection in clinical practice.

    PubMed

    Carling, Philip C; Perkins, Jennifer; Ferguson, JoAnn; Thomasser, Anita

    2014-11-01

    Despite an increasing understanding of the importance of near-patient surfaces in the transmission of healthcare-associated pathogens, there remains a need to define the relative clinical effectiveness of disinfection interventions. A serial 2-phase evaluation of the clinical effectiveness of 2 surface disinfectants. A general acute care hospital. A unique system for quantifying bioburden reduction while monitoring the possible impact of differences in cleaning thoroughness was used to compare the clinical effectiveness of a traditional quaternary ammonium compound (QAC) and a novel peracetic acid/hydrogen peroxide disinfectant (ND) as part of terminal room cleaning. As a result of QAC cleaning, 93 (40%) of 237 cleaned surfaces confirmed by fluorescent marker (DAZO) removal were found to have complete removal of aerobic bioburden. During the ND phase of the study, bioburden was removed from 211 (77%) of 274 cleaned surfaces. Because there was no difference in the thoroughness of cleaning with either disinfectant (65.3% and 66.4%), the significant ([Formula: see text]) difference in bioburden reduction can be attributed to better cleaning efficacy with the ND. In the context of the study design, the ND was 1.93 times more effective in removing bacterial burden than the QAC ([Formula: see text]). Furthermore, the study design represents a new research paradigm in which 2 interventions can be compared by concomitantly and objectively analyzing both the product and process variables in a manner that can be used to define the relative effectiveness of all disinfection cleaning interventions.

  19. IMPROVED EQUIPMENT CLEANING IN COATED AND LAMINATED SUBSTRATE MANUFACTURING FACILITIES (PHASE I)

    EPA Science Inventory

    The report gives results of a Phase I study to characterize current equipment cleaning practices in the coated and laminated substrate manufacturing industry, to identify alternative cleaning technologies, and to identify demonstrable technologies and estimate their emissions imp...

  20. A Study of the Characteristics of Human-Pilot Control Response to Simulated Aircraft Lateral Motions

    NASA Technical Reports Server (NTRS)

    Cheatham, Donald C

    1954-01-01

    Report presents the results of studies made in an attempt to provide information on the control operations of the human pilot. These studies included an investigation of the ability of pilots to control simulated unstable yawing oscillations, a study of the basic characteristics of human-pilot control response, and a study to determine whether and to what extent pilot control response can be represented in an analytical form.

  1. Materials compatibility and aging for flux and cleaner combinations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Archuleta, Kim M.; Piatt, Rochelle

    2015-01-01

    A materials study of high reliability electronics cleaning is presented here. In Phase 1, mixed type substrates underwent a condensed contaminants application to view a worst- case scenario for unremoved flux with cleaning agent residue for parts in a silicone oil filled environment. In Phase 2, fluxes applied to copper coupons and to printed wiring boards underwent gentle cleaning then accelerated aging in air at 65% humidity and 30 O C. Both sets were aged for 4 weeks. Contaminants were no-clean (ORL0), water soluble (ORH1 liquid and ORH0 paste), and rosin (RMA; ROL0) fluxes. Defluxing agents were water, solvents, andmore » engineered aqueous defluxers. In the first phase, coupons had flux applied and heated, then were placed in vials of oil with a small amount of cleaning agent and additional coupons. In the second phase, pairs of copper coupons and PWB were hand soldered by application of each flux, using tin-lead solder in a strip across the coupon or a set of test components on the PWB. One of each pair was cleaned in each cleaning agent, the first with a typical clean, and the second with a brief clean. Ionic contamination residue was measured before accelerated aging. After aging, substrates were removed and a visual record of coupon damage made, from which a subjective rank was applied for comparison between the various flux and defluxer combinations; more corrosion equated to higher rank. The ORH1 water soluble flux resulted in the highest ranking in both phases, the RMA flux the least. For the first phase, in which flux and defluxer remained on coupons, the aqueous defluxers led to worse corrosion. The vapor phase cleaning agents resulted in the highest ranking in the second phase, in which there was no physical cleaning. Further study of cleaning and rinsing parameters will be required.« less

  2. Syn-Fuel reciprocating charge pump improvement program. Quarterly technical project report, April-June 1984

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1984-01-01

    Major accomplishments during the second quarter of 1984 were completion of the Diaphragm Separation Seal clear liquid testing, and initiation of Phase III Field Testing. Diaphragm operational testing was conducted on a clear water test loop. The test goals were to ensure; mechanical reliability of the Diaphragm Seal, safe operation with simulated component failure, and proper operation of the Diaphragm Buffer Volume Control System. This latter system is essential in controlling the phasing of the diaphragm with its driving plunger. These tests were completed successfully. All operational problems were solved. However, it must be emphasized that the Diaphragm Seal wouldmore » be damaged by allowing the pump to operate in a cavitating condition for an extended period of time. A change in the Field Test phase of the program was made regarding choice of field test site. There is no operating Syn-Fuel pilot plant capable of inexpensively producing the slurry stream required for the reciprocating pump testing. The Field Tests will now be conducted by first testing the prototype pump and separation seals in an ambient temperature sand water slurry. This will determine resistence to abrasive wear and determine any operation problems at pressure over a lengthy period of time. After successful conclusion of these tests the pump and seals will be operated with a high temperature oil, but without solids, to identify any problems associated with thermal gradients, thermal shock and differential growth. After successful completion of the high temperature clean oil tests the pump will be deemed ready for in-line installation at a designated Syn-Fuel pilot plant. The above approach avoids the expense and complications of a separate hot slurry test loop. It also reduces risk of operational problems while in-line at the pilot plant. 5 figs.« less

  3. Profiling of new psychoactive substances (NPS) by using stable isotope ratio mass spectrometry (IRMS): study on the synthetic cannabinoid 5F-PB-22.

    PubMed

    Münster-Müller, S; Scheid, N; Holdermann, T; Schneiders, S; Pütz, M

    2018-05-21

    In this paper results of a pilot study on the profiling of the synthetic cannabinoid receptor agonist 5F-PB-22 (5F-QUPIC, pentylfluoro-1H-indole-3-carboxylic acid-8-quinolinyl ester) via isotope ratio mass spectrometry are presented. It is focused on δ 13 C, δ 15 N and δ 2 H isotope ratios, which are determined using elemental analyser (EA) and high temperature elemental analyser (TC/EA) coupled to an isotope ratio mass spectrometer (IRMS). By means of a sample of pure material of 5F-PB-22 it is shown that the extraction of 5F-PB-22 from herbal material, a rapid clean-up procedure, or preparative column chromatography had no influences on the isotope ratios. Furthermore, 5F-PB-22 was extracted from fourteen different herbal blend samples ("Spice products" from police seizures) and analysed via IRMS, yielding three clusters containing seven, five and two samples, distinguishable through their isotopic composition, respectively. It is assumed that herbal blends in each cluster have been manufactured from individual batches of 5F-PB-22. This article is protected by copyright. All rights reserved.

  4. Testing neoclassical competitive market theory in the field

    PubMed Central

    List, John A.

    2002-01-01

    This study presents results from a pilot field experiment that tests predictions of competitive market theory. A major advantage of this particular field experimental design is that my laboratory is the marketplace: subjects are engaged in buying, selling, and trading activities whether I run an exchange experiment or am a passive observer. In this sense, I am gathering data in a natural environment while still maintaining the necessary control to execute a clean comparison between treatments. The main results of the study fall into two categories. First, the competitive model predicts reasonably well in some market treatments: the expected price and quantity levels are approximated in many market rounds. Second, the data suggest that market composition is important: buyer and seller experience levels impact not only the distribution of rents but also the overall level of rents captured. An unexpected result in this regard is that average market efficiency is lowest in markets that match experienced buyers and experienced sellers and highest when experienced buyers engage in bargaining with inexperienced sellers. Together, these results suggest that both market experience and market composition play an important role in the equilibrium discovery process. PMID:12432103

  5. Theoretical and Experimental Investigations of the Potential of Osmotic Energy for Power Production †

    PubMed Central

    Sharif, Adel O.; Merdaw, Ali A.; Aryafar, Maryam; Nicoll, Peter

    2014-01-01

    This paper presents a study on the potential of osmotic energy for power production. The study includes both pilot plant testing and theoretical modelling as well as cost estimation. A projected cost of £30/MWh of clean electricity could be achieved by using a Hydro-Osmotic Power (HOP) plant if a suitable membrane is used and the osmotic potential difference between the two solutions is greater than 25 bar; a condition that can be readily found in many sites around the world. Results have shown that the membrane system accounts for 50%–80% of the HOP plant cost depending on the salinity difference level. Thus, further development in membrane technology and identifying suitable membranes would have a significant impact on the feasibility of the process and the route to market. As the membrane permeability determines the HOP process feasibility, this paper also describes the effect of the interaction between the fluid and the membrane on the system permeability. It has been shown that both the fluid physical properties as well as the membrane micro-structural parameters need to be considered if further development of the HOP process is to be achieved. PMID:25110959

  6. Theoretical and experimental investigations of the potential of osmotic energy for power production.

    PubMed

    Sharif, Adel O; Merdaw, Ali A; Aryafar, Maryam; Nicoll, Peter

    2014-08-08

    This paper presents a study on the potential of osmotic energy for power production. The study includes both pilot plant testing and theoretical modelling as well as cost estimation. A projected cost of £30/MWh of clean electricity could be achieved by using a Hydro-Osmotic Power (HOP) plant if a suitable membrane is used and the osmotic potential difference between the two solutions is greater than 25 bar; a condition that can be readily found in many sites around the world. Results have shown that the membrane system accounts for 50%-80% of the HOP plant cost depending on the salinity difference level. Thus, further development in membrane technology and identifying suitable membranes would have a significant impact on the feasibility of the process and the route to market. As the membrane permeability determines the HOP process feasibility, this paper also describes the effect of the interaction between the fluid and the membrane on the system permeability. It has been shown that both the fluid physical properties as well as the membrane micro-structural parameters need to be considered if further development of the HOP process is to be achieved.

  7. Clean hands: prevention of typhoid fever in rural communities in Egypt.

    PubMed

    Lohiniva, Anna L; Saeed, Mohamed; El-Sayeed, Nasr; Talaat, Maha

    Typhoid fever is a serious public health problem in Egypt. Effective prevention strategies include the promotion of handwashing. This study explores factors that influence handwashing practices in the Egyptian setting and makes recommendations on how to use this information in a handwashing campaign. In addition to key informant interviews, 16 focus group discussions and 21 in-depth interviews were carried out with female respondents in three different rural sites. The data was analyzed by using content analysis technique. The findings showed that the concept of dirt (microbaat and talaus) influences hygiene behavior as it relates to the outside (i.e., real and visible things). The respondents have low risk perceptions related to typhoid fever and they do not conceptualize long disease transmission chains. The scarcity of water and problems with disposal of waste water hinder handwashing. These findings were incorporated into a pilot campaign to promote handwashing using strategies that included the visualization of germs in critical areas during critical times, discussions of germ theory, and encouragement to solve environmental and infrastructural constraints that hinder handwashing practices at the household level.

  8. DOE Office of Scientific and Technical Information (OSTI.GOV)

    James K. Neathery; Gary Jacobs; Burtron H. Davis

    In this reporting period, a fundamental filtration study was started to investigate the separation of Fischer-Tropsch Synthesis (FTS) liquids from iron-based catalyst particles. Slurry-phase FTS in slurry bubble column reactor systems is the preferred mode of production since the reaction is highly exothermic. Consequently, heavy wax products must be separated from catalyst particles before being removed from the reactor system. Achieving an efficient wax product separation from iron-based catalysts is one of the most challenging technical problems associated with slurry-phase FTS. The separation problem is further compounded by catalyst particle attrition and the formation of ultra-fine iron carbide and/or carbonmore » particles. Existing pilot-scale equipment was modified to include a filtration test apparatus. After undergoing an extensive plant shakedown period, filtration tests with cross-flow filter modules using simulant FTS wax slurry were conducted. The focus of these early tests was to find adequate mixtures of polyethylene wax to simulate FTS wax. Catalyst particle size analysis techniques were also developed. Initial analyses of the slurry and filter permeate particles will be used by the research team to design improved filter media and cleaning strategies.« less

  9. The G-HAT Search for Advanced Extraterrestrial Civilizations: The Reddest Extended WISE Sources

    NASA Astrophysics Data System (ADS)

    Maldonado, Jessica; Povich, Matthew S.; Wright, Jason; Griffith, Roger; Sigurdsson, Steinn; Mullan, Brendan L.

    2015-01-01

    Freeman Dyson (1960) theorized how to identify possible signatures of advanced extra-terrestrial civilizations by their waste heat, an inevitable byproduct of a civilization using a significant fraction of the luminosity from their host star. If a civilizations could tap the starlight throughout their host galaxy their waste heat would be easily detectable by recent infrared surveys. The Glimpsing Heat from Alien Technologies (G-HAT) pilot project aims to place limits on the existence of extraterrestrial civilizations at pan-galactic scales. We present results from the G-HAT cleaned catalog of 563 extremely red, extended high Galactic latitude (|b| ≥ 10) sources from the WISE All-Sky Catalog. Our catalog includes sources new to the scientific literature along with well-studied objects (e.g. starburst galaxies, AGN, and planetary nebulae) that exemplify extreme WISE colors. Objects of particular interest include a supergiant Be star (48 Librae) surrounded by a resolved, mid-infrared nebula, possibly indicating dust in the stellar wind ejecta, and a curious cluster of seven extremely red WISE sources (associated with IRAS 04287+6444) that have no optical counterparts.

  10. Liquid phase fluid dynamic (methanol) run in the LaPorte alternative fuels development unit

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bharat L. Bhatt

    1997-05-01

    A fluid dynamic study was successfully completed in a bubble column at DOE's Alternative Fuels Development Unit (AFDU) in LaPorte, Texas. Significant fluid dynamic information was gathered at pilot scale during three weeks of Liquid Phase Methanol (LPMEOJP) operations in June 1995. In addition to the usual nuclear density and temperature measurements, unique differential pressure data were collected using Sandia's high-speed data acquisition system to gain insight on flow regime characteristics and bubble size distribution. Statistical analysis of the fluctuations in the pressure data suggests that the column was being operated in the churn turbulent regime at most of themore » velocities considered. Dynamic gas disengagement experiments showed a different behavior than seen in low-pressure, cold-flow work. Operation with a superficial gas velocity of 1.2 ft/sec was achieved during this run, with stable fluid dynamics and catalyst performance. Improvements included for catalyst activation in the design of the Clean Coal III LPMEOH{trademark} plant at Kingsport, Tennessee, were also confirmed. In addition, an alternate catalyst was demonstrated for LPMEOH{trademark}.« less

  11. Retention-oxidation-adsorption process for emergent treatment of organic liquid spills.

    PubMed

    Liu, Xianjun; Li, Yu; Zhang, Xingwang; Lei, Lecheng

    2011-11-15

    The feasibility and effectiveness of retention-oxidation-adsorption process (ROA) for the elimination of organic contaminants induced by chemical accidents were investigated in this study. Organobentonites (DTMA-, TTA-, CTMA- and OTMA-bentonite), potassium ferrate (Fe(VI)), ozone and granular activated carbon (GAC) were used as rapid and efficient materials in the treatment and recovery of organic liquid spills. Results indicated that the retention capacities of organobentonites (especially CTMA-bentonite) were much higher than that of natural bentonite towards the chosen organic compounds. Additionally, pH, oxidant dosage, initial concentration of contaminant and chemical structure had significant influences on the effectiveness of the oxidation process. In a pilot-scale experiment, the ferrate/GAC (F/G) and ozone/GAC (O/G) processes made a comparatively good performance in the treatment of wastewater containing aniline or nitrobenzene, with the removal efficiencies of the contaminants greater than 80%. Overall, the ROA process showed a high efficiency and steady operation in the removal of hazardous organic liquids and subsequent clean up of the contaminated site. Crown Copyright © 2011. Published by Elsevier B.V. All rights reserved.

  12. MINIMIZING POLLUTION IN CLEANING AND DEGREASING OPERATIONS

    EPA Science Inventory

    The objective of this study was to examine approaches to decreasing rates of loss by evaporation and extend@ the useful lifetime of metal-cleaning solvents in service as means to decrease the generation of pollutant emissions and residues from Air Force cleaning and degreasing op...

  13. Asthma risk, cleaning activities and use of specific cleaning products among Spanish indoor cleaners.

    PubMed

    Zock, J P; Kogevinas, M; Sunyer, J; Almar, E; Muniozguren, N; Payo, F; Sánchez, J L; Antó, J M

    2001-02-01

    Recent studies have shown an excess risk of asthma for cleaners, but it is not clear which cleaning-related exposures induce or aggravate asthma. Risk factors for asthma were studied among indoor cleaners participating in the Spanish part of the European Community Respiratory Health Survey in 1992. In 1998, 78 of the 91 subjects reporting cleaning-related jobs in 1992 were identified. Of these, 67 indoor cleaners were interviewed by telephone about their cleaning activities and their use of cleaning products in 1992. These data were related to asthma prevalence in 1992, and the cleaners were compared with a reference group of office workers. Asthma prevalence was 1.7 times higher [95% confidence interval (95% CI) 1.1-2.6] among the cleaners than among the referents, being highest among private home cleaners (3.3, 95% CI 1.9-5.8). The prevalence of housedust mite sensitization amounted to 28% for the home cleaners and was significantly (P<0.01) higher than for other indoor cleaners (3%), but similar to the corresponding prevalence of office workers (22%). More than half of the cleaners reported work-related respiratory symptoms. The asthma risk of the home cleaners was mainly associated with kitchen cleaning and furniture polishing, with the use of oven sprays and polishes. The asthma risk of Spanish cleaners is primarily related to the cleaning of private homes. This relationship may be explained by the use of sprays and other products in kitchen cleaning and furniture polishing.

  14. Is peracetic acid suitable for the cleaning step of reprocessing flexible endoscopes?

    PubMed

    Kampf, Günter; Fliss, Patricia M; Martiny, Heike

    2014-09-16

    The bioburden (blood, protein, pathogens and biofilm) on flexible endoscopes after use is often high and its removal is essential to allow effective disinfection, especially in the case of peracetic acid-based disinfectants, which are easily inactivated by organic material. Cleaning processes using conventional cleaners remove a variable but often sufficient amount of the bioburden. Some formulations based on peracetic acid are recommended by manufacturers for the cleaning step. We performed a systematic literature search and reviewed the available evidence to clarify the suitability of peracetic acid-based formulations for cleaning flexible endoscopes. A total of 243 studies were evaluated. No studies have yet demonstrated that peracetic acid-based cleaners are as effective as conventional cleaners. Some peracetic acid-based formulations have demonstrated some biofilm-cleaning effects and no biofilm-fixation potential, while others have a limited cleaning effect and a clear biofilm-fixation potential. All published data demonstrated a limited blood cleaning effect and a substantial blood and nerve tissue fixation potential of peracetic acid. No evidence-based guidelines on reprocessing flexible endoscopes currently recommend using cleaners containing peracetic acid, but some guidelines clearly recommend not using them because of their fixation potential. Evidence from some outbreaks, especially those involving highly multidrug-resistant gram-negative pathogens, indicated that disinfection using peracetic acid may be insufficient if the preceding cleaning step is not performed adequately. Based on this review we conclude that peracetic acid-based formulations should not be used for cleaning flexible endoscopes.

  15. Is peracetic acid suitable for the cleaning step of reprocessing flexible endoscopes?

    PubMed Central

    Kampf, Günter; Fliss, Patricia M; Martiny, Heike

    2014-01-01

    The bioburden (blood, protein, pathogens and biofilm) on flexible endoscopes after use is often high and its removal is essential to allow effective disinfection, especially in the case of peracetic acid-based disinfectants, which are easily inactivated by organic material. Cleaning processes using conventional cleaners remove a variable but often sufficient amount of the bioburden. Some formulations based on peracetic acid are recommended by manufacturers for the cleaning step. We performed a systematic literature search and reviewed the available evidence to clarify the suitability of peracetic acid-based formulations for cleaning flexible endoscopes. A total of 243 studies were evaluated. No studies have yet demonstrated that peracetic acid-based cleaners are as effective as conventional cleaners. Some peracetic acid-based formulations have demonstrated some biofilm-cleaning effects and no biofilm-fixation potential, while others have a limited cleaning effect and a clear biofilm-fixation potential. All published data demonstrated a limited blood cleaning effect and a substantial blood and nerve tissue fixation potential of peracetic acid. No evidence-based guidelines on reprocessing flexible endoscopes currently recommend using cleaners containing peracetic acid, but some guidelines clearly recommend not using them because of their fixation potential. Evidence from some outbreaks, especially those involving highly multidrug-resistant gram-negative pathogens, indicated that disinfection using peracetic acid may be insufficient if the preceding cleaning step is not performed adequately. Based on this review we conclude that peracetic acid-based formulations should not be used for cleaning flexible endoscopes. PMID:25228941

  16. [Study on assistant cleaning of ultrasound for the ultrafiltration membrane].

    PubMed

    Zhang, Guojun; Liu, Zhongzhou

    2003-11-01

    The effects of ultrasounds with different frequency on membrane performance were investigated in this paper. The experimental results show that there were nearly no effects of 20 W ultrasound on membrane retention coefficient, but it decreased seriously when the ultrasound power was above 30 W. On the basis of these results, low frequency ultrasound (20 W) was introduced to assist the chemical cleaning in the ultrafiltration process of wastewater from bank note printing works. The cleaning time could be shortened from 20-30 min to 5 min by the ultra-liberation and ultra-blend effects of ultrasound, therefore, the cleaning efficiency was highly improved. However, the fouling substances could not be cleaned entirely in the simple physical cleaning process by SEM analysis.

  17. [Surface disinfection in nursing homes--what is really happening? Study of control success in three Duisburg nursing homes].

    PubMed

    Martin, U; Sonntag, A-K; Neuhaus, B; Karch, H

    2004-10-01

    The effectiveness of cleaning and disinfection of environmental surfaces was evaluated in three nursing homes using bacteriological monitoring. Samples from inmates (nose, throat and wounds) and surface cleaning equipment were also taken. Cleaning solutions, disinfectants and cleaning clothes were found to be highly contaminated in two of three institutions. Referring to the surfaces in some cases disinfection didn't reduce bacterial colony counts and seeded MRSA as a potential pathogen in one nursing home. Six MRSA-positive inmates and identical strains were registered in the environment. MRSA can be used as a marker organism to demonstrate effectiveness of cleaning. To achieve further improvement bacteriological monitoring can help in focussing special cleaning and disinfection related problems.

  18. Cleaning Aged EPDM Rubber Roofing Membrane Material for Patching: Laboratory Investigations and Recommendations

    DTIC Science & Technology

    1992-08-01

    Cleaning Aged EPDM Rubber Roofing Membrane Material for Patching: Laboratory Investigations and Recommendations Walter J. Rossiter, Jr. T N n-’T ic...condition of the aged EPDM rubber before bonding. This study assessed the effectiveness of different cleaning methods for preparing aged EPDM membranes for...REPORT DATE 3. REPORT TYPE AND DATES COVERED August 1992 Final 4. TITLE AND SUBTITLE 5. FUNDING NUMBERS Cleaning Aged EPDM Rubber Roofing Membrane

  19. Pilot Certification, Age of Pilot, and Drug Use in Fatal Civil Aviation Accidents.

    PubMed

    Akparibo, Issaka Y; Stolfi, Adrienne

    2017-10-01

    This study examined the association between mean age of pilot, pilot license, pilot medical certificate and drug use trends in pilots fatally injured in aircraft accidents. The prevalence of prescription drugs, OTC drugs, controlled drugs and drugs that may be potentially impairing was also examined. This study was a descriptive observational study in which the NTSB Aviation Accident Database was searched from the period beginning January 1, 2012 to December 31, 2014. During the study period a total of 706 accidents involving 711 fatalities were investigated by the NTSB. This study included 633 of these accidents, involving 646 fatalities. Of these pilots, 42.1% had drugs in their biological samples. The prevalence of prescription drugs, controlled drugs, OTC drugs, opioids, and potentially impairing drugs in the fatally injured pilot population over the study period was 28.9%, 15.0%, 20.1%, 5.1%, and 25.5%, respectively. Pilots with any drugs in their samples were significantly older than those without drugs. Medical certificate held was associated with drug use; pilots who held third class certificates had the highest prevalence at 54.1%. Pilot license was not associated with drug use. In 3.8% of the accidents, drugs were a contributing factor in the cause. Despite current FAA medical regulations, potentially impairing drugs are frequently found in biological samples of fatally injured pilots in the U.S. More education of airmen by aviation medical examiners is needed on the safety of drug use.Akparibo IY, Stolfi A. Pilot certification, age of pilot, and drug use in fatal civil aviation accidents. Aerosp Med Hum Perform. 2017; 88(10):931-936.

  20. A method for encoding clinical datasets with SNOMED CT.

    PubMed

    Lee, Dennis H; Lau, Francis Y; Quan, Hue

    2010-09-17

    Over the past decade there has been a growing body of literature on how the Systematised Nomenclature of Medicine Clinical Terms (SNOMED CT) can be implemented and used in different clinical settings. Yet, for those charged with incorporating SNOMED CT into their organisation's clinical applications and vocabulary systems, there are few detailed encoding instructions and examples available to show how this can be done and the issues involved. This paper describes a heuristic method that can be used to encode clinical terms in SNOMED CT and an illustration of how it was applied to encode an existing palliative care dataset. The encoding process involves: identifying input data items; cleaning the data items; encoding the cleaned data items; and exporting the encoded terms as output term sets. Four outputs are produced: the SNOMED CT reference set; interface terminology set; SNOMED CT extension set and unencodeable term set. The original palliative care database contained 211 data elements, 145 coded values and 37,248 free text values. We were able to encode ~84% of the terms, another ~8% require further encoding and verification while terms that had a frequency of fewer than five were not encoded (~7%). From the pilot, it would seem our SNOMED CT encoding method has the potential to become a general purpose terminology encoding approach that can be used in different clinical systems.

  1. Lung volume changes during cleaning of closed endotracheal suction catheters: a randomized crossover study using electrical impedance tomography.

    PubMed

    Corley, Amanda; Sharpe, Nicola; Caruana, Lawrence R; Spooner, Amy J; Fraser, John F

    2014-04-01

    Airway suctioning in mechanically ventilated patients is required to maintain airway patency. Closed suction catheters (CSCs) minimize lung volume loss during suctioning but require cleaning post-suction. Despite their widespread use, there is no published evidence examining lung volumes during CSC cleaning. The study objectives were to quantify lung volume changes during CSC cleaning and to determine whether these changes were preventable using a CSC with a valve in situ between the airway and catheter cleaning chamber. This prospective randomized crossover study was conducted in a metropolitan tertiary ICU. Ten patients mechanically ventilated via volume-controlled synchronized intermittent mandatory ventilation (SIMV-VC) and requiring manual hyperinflation (MHI) were included in this study. CSC cleaning was performed using 2 different brands of CSC (one with a valve [Ballard Trach Care 72, Kimberly-Clark, Roswell, Georgia] and one without [Portex Steri-Cath DL, Smiths Medical, Dublin, Ohio]). The maneuvers were performed during both SIMV-VC and MHI. Lung volume change was measured via impedance change using electrical impedance tomography. A mixed model was used to compare the estimated means. During cleaning of the valveless CSC, significant decreases in lung impedance occurred during MHI (-2563 impedance units, 95% CI 2213-2913, P < .001), and significant increases in lung impedance occurred during SIMV (762 impedance units, 95% CI 452-1072, P < .001). In contrast, cleaning of the CSC with a valve in situ resulted in non-significant lung volume changes and maintenance of normal ventilation during MHI and SIMV-VC, respectively (188 impedance units, 95% CI -136 to 511, P = .22; and 22 impedance units, 95% CI -342 to 299, P = .89). When there is no valve between the airway and suction catheter, cleaning of the CSC results in significant derangements in lung volume. Therefore, the presence of such a valve should be considered essential in preserving lung volumes and uninterrupted ventilation in mechanically ventilated patients.

  2. Clean delivery practices in rural northern Ghana: a qualitative study of community and provider knowledge, attitudes, and beliefs

    PubMed Central

    2012-01-01

    Background Knowledge, attitudes and practices of community members and healthcare providers in rural northern Ghana regarding clean delivery are not well understood. This study explores hand washing/use of gloves during delivery, delivering on a clean surface, sterile cord cutting, appropriate cord tying, proper cord care following delivery, and infant bathing and cleanliness. Methods In-depth interviews and focus group discussions were audiotaped, transcribed, and analyzed using NVivo 9.0. Results 253 respondents participated, including women with newborn infants, grandmothers, household and compound heads, community leaders, traditional birth attendants, and formally trained health care providers. There is widespread understanding of the need for clean delivery to reduce the risk of infection to both mothers and their babies during and shortly after delivery. Despite this understanding, the use of gloves during delivery and hand washing during and after delivery were mentioned infrequently. The need for a clean delivery surface was raised repeatedly, including explicit discussion of avoiding delivering in the dirt. Many activities to do with cord care involved non-sterile materials and practices: 1) Cord cutting was done with a variety of tools, and the most commonly used were razor blades or scissors; 2) Cord tying utilized a variety of materials, including string, rope, thread, twigs, and clamps; and 3) Cord care often involved applying traditional salves to the cord - including shea butter, ground shea nuts, local herbs, local oil, or “red earth sand.” Keeping babies and their surroundings clean was mentioned repeatedly as an important way to keep babies from falling ill. Conclusions This study suggests a widespread understanding in rural northern Ghana of the need for clean delivery. Nonetheless, many recommended clean delivery practices are ignored. Overarching themes emerging from this study included the increasing use of facility-based delivery, the disconnect between healthcare providers and the community, and the critical role grandmothers play in ensuring clean delivery practices. Future interventions to address clean delivery and prevention of neonatal infections include educating healthcare providers about harmful traditional practices so they are specifically addressed, strengthening facilities, and incorporating influential community members such as grandmothers to ensure success. PMID:22703032

  3. Clean delivery practices in rural northern Ghana: a qualitative study of community and provider knowledge, attitudes, and beliefs.

    PubMed

    Moyer, Cheryl A; Aborigo, Raymond Akawire; Logonia, Gideon; Affah, Gideon; Rominski, Sarah; Adongo, Philip B; Williams, John; Hodgson, Abraham; Engmann, Cyril

    2012-06-15

    Knowledge, attitudes and practices of community members and healthcare providers in rural northern Ghana regarding clean delivery are not well understood. This study explores hand washing/use of gloves during delivery, delivering on a clean surface, sterile cord cutting, appropriate cord tying, proper cord care following delivery, and infant bathing and cleanliness. In-depth interviews and focus group discussions were audiotaped, transcribed, and analyzed using NVivo 9.0. 253 respondents participated, including women with newborn infants, grandmothers, household and compound heads, community leaders, traditional birth attendants, and formally trained health care providers. There is widespread understanding of the need for clean delivery to reduce the risk of infection to both mothers and their babies during and shortly after delivery. Despite this understanding, the use of gloves during delivery and hand washing during and after delivery were mentioned infrequently. The need for a clean delivery surface was raised repeatedly, including explicit discussion of avoiding delivering in the dirt. Many activities to do with cord care involved non-sterile materials and practices: 1) Cord cutting was done with a variety of tools, and the most commonly used were razor blades or scissors; 2) Cord tying utilized a variety of materials, including string, rope, thread, twigs, and clamps; and 3) Cord care often involved applying traditional salves to the cord - including shea butter, ground shea nuts, local herbs, local oil, or "red earth sand." Keeping babies and their surroundings clean was mentioned repeatedly as an important way to keep babies from falling ill. This study suggests a widespread understanding in rural northern Ghana of the need for clean delivery. Nonetheless, many recommended clean delivery practices are ignored. Overarching themes emerging from this study included the increasing use of facility-based delivery, the disconnect between healthcare providers and the community, and the critical role grandmothers play in ensuring clean delivery practices. Future interventions to address clean delivery and prevention of neonatal infections include educating healthcare providers about harmful traditional practices so they are specifically addressed, strengthening facilities, and incorporating influential community members such as grandmothers to ensure success.

  4. Surface cleaning for negative electron affinity GaN photocathode

    NASA Astrophysics Data System (ADS)

    Qiao, Jianliang; Yin, Yingpeng; Gao, Youtang; Niu, Jun; Qian, Yunsheng; Chang, Benkang

    2012-10-01

    In the preparation process for negative electron affinity (NEA) GaN photocathode, the surface cleanness is very important to activation, it influences the sensitivity and stability of NEA GaN photocathode. The traditional corrosion methods based on oxidizing and dissolving can't remove oxygen (O) and carbon (C) on GaN surface effectively. How to get an ideal atom clean surface is still an important question at present. The cleaning techniques for GaN photocathode was studied by using NEA photocathode activation system and XPS surface analysis system. The experiment sample is p-type GaN doped with Mg, doped concentration is 1.37×1017 cm-3, the transfer rate is 3.08 cm2/V-S, and the thickness of activation layer is 0.51 μm, the substrate is 300 μm thick sapphire. The sample was dealed with chemical cleaning depuration at first. And to get the atom clean surface, the vacuum heat cleaning process was needed. The methods of chemical cleaning and the vacuum heating cleaning were given in detail. According to the X-ray photoelectron spectroscopy of GaN surface after chemical cleaning and the vacuum degree curve of the activation chamber during the heat cleaning, the cleaning effect and the cleaning mechanism were discussed. After the effective chemical cleaning and the heating of 700 Centigrade degree about 20 minutes in ultrahigh vacuum system, the oxides and carbon contaminants on cathode surface can be removed effectively, and the ideal atom clean surface can be obtained. The purpose of heating depuration process is that not only to get the atom clean GaN surface, but also to guarantee the contents of Ga, N on GaN surface stabilize and to keep the system ultra-high vacuum degree. Because of the volatilization of oxide and carbon impurity on the cathode surface, the vacuum degree curve drops with the rising of temperature on the whole.

  5. Removal of brownish-black tarnish on silver-copper alloy objects with sodium glycinate

    NASA Astrophysics Data System (ADS)

    de Figueiredo, João Cura D.'Ars; Asevedo, Samara Santos; Barbosa, João Henrique Ribeiro

    2014-10-01

    This article has the principal aim of presenting a new method of chemical cleaning of tarnished silver-copper alloy objects. The chemical cleaning must be harmless to the health, selective to tarnish removal, and easy to use. Sodium glycinate was selected for the study. The reactions of sodium glycinate with tarnish and the silver-copper alloy were evaluated. Products of the reaction, the lixiviated material, and the esthetics of silver-copper alloy coins (used as prototypes) were studied to evaluate if the proposed method can be applied to the cleaning of silver objects. Silver-copper alloys can be deteriorated through a uniform and superficial corrosion process that produces brownish-black tarnish. This tarnish alters the esthetic of the object. The cleaning of artistic and archeological objects requires more caution than regular cleaning, and it must take into account the procedures for the conservation and restoration of cultural heritage. There are different methods for cleaning silver-copper alloy objects, chemical cleaning is one of them. We studied two chemical cleaning methods that use sodium glycinate and sodium acetylglycinate solutions. Silver-copper alloy coins were artificially corroded in a basic thiourea solution and immersed in solutions of sodium glycinate and sodium acetylglycinate. After immersion, optical microscopy and scanning electron microscopy of the surfaces were studied. The sodium glycinate solution was shown to be very efficient in removing the brownish-black tarnish. Absorption spectroscopy measured the percentage of silver and copper lixiviated in immersion baths, and very small quantities of these metals were detected. Infrared absorption spectroscopy and X-ray fluorescence characterized the obtained products. The greater efficiency of the sodium glycinate solution compared to the sodium acetylglycinate solution was explained by chelation and Hard-Soft Acid-Base Theory with the aid of quantum chemical calculations.

  6. Identification of sewer pipes to be cleaned for reduction of CSO pollutant load.

    PubMed

    Nagaiwa, Akihiro; Settsu, Katsushi; Nakajima, Fumiyuki; Furumai, Hiroaki

    2007-01-01

    To reduce the CSO (Combined Sewer Overflow) pollutant discharge, one of the effective options is cleaning of sewer pipes before rainfall events. To maximize the efficiency, identification of pipes to be cleaned is necessary. In this study, we discussed the location of pipe deposit in dry weather in a combined sewer system using a distributed model and investigated the effect of pipe cleaning to reduce the pollutant load from the CSO. First we simulated the dry weather flow in a combined sewer system. The pipe deposit distribution in the network was estimated after 3 days of dry weather period. Several specific pipes with structural defect and upper end pipes tend to have an accumulation of deposit. Wet weather simulations were conducted with and without pipe cleaning in rainfall events with different patterns. The SS loads in CSO with and without the pipe cleaning were compared. The difference in the estimated loads was interpreted as the contribution of wash-off in the cleaned pipe. The effect of pipe cleaning on reduction of the CSO pollutant load was quantitatively evaluated (e.g. the cleaning of one specific pipe could reduce 22% of total CSO load). The CSO simulations containing pipe cleaning options revealed that identification of pipes with accumulated deposit using the distributed model is very useful and informative to evaluate the applicability of pipe cleaning option for CSO pollutant reduction.

  7. Survey of Hearth Products in U.S. Homes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Siap, David; Willem, Henry; Price, Sarah K.

    There are over 7 million gas-fired fireplaces currently installed in US households. On an annual basis, these use substantial energy. However, the details of the fireplace energy use and the factors that influence it are currently not well understood. Fireplaces are a type of hearth product, which is a product category that primarily consists of fireplaces, stoves, and gas log sets. For the purpose of this study, the fuels used in hearth products are primarily natural gas, propane, or electricity. They may be vented or unvented. This study reports the results of a web survey of 2,100 respondents in themore » United States performed in February 2016. The responses were cleaned and weighted using the raking method to form a nationally representative population. The reported data include hearth product characteristics, usage information, and repair and maintenance practices. The hearth product characteristics include the hearth product type, fuel type, ignition system type, features, venting, and installation details. The usage information includes seasonal usage of the main burner and standing pilot (if present), daily usage, and the primary utility (whether decorative or for heating). These raw data are further processed and combined with values from the literature to estimate the annual operating hours and energy use and to assess how these are impacted by the hearth product type, features, age, and the main heating appliance, if present. Based on the survey responses, the estimated average annual hours of usage was 234 for the main burner, and 4,593 for the standing pilot. The results presented provide the most comprehensive data regarding hearth products in the United States published to date. These new data allow for an improved understanding of hearth products’ energy use, which in turn may facilitate the development of more informed analyses, and ultimately more efficient hearth products and reduced energy use. These new data also provide insight into topics not previously studied, such as the effect of hearth product features on energy use.« less

  8. A salivary incubation test for evaluation of oral malodor: a pilot study.

    PubMed

    Quirynen, Marc; Zhao, Hong; Avontroodt, Pieter; Soers, Catherine; Pauwels, Martine; Coucke, Wim; van Steenberghe, Daniel

    2003-07-01

    Breath odor is scored by different techniques, each with its own shortcomings. Organoleptic ratings are uncomfortable for the patient, subjective, influenced by external parameters including food and cosmetics, and especially lack international calibration. Portable sulphide monitors are relatively expensive and neglect several major malodorous molecules (e.g., butyric and propionic acids, putrescine, and cadaverine). Gas chromatography necessitates expensive devices and experienced technicians. This pilot study explored the applicability of a new technique (saliva incubation) by comparing its discrimination power, in a morning bad breath inhibition study of antiseptics, to those of hydrogen sulphide (H2S) measurement devices and organoleptic ratings. After a professional cleaning, 8 periodontally healthy students abstained from all means of mechanical plaque control for 5 experimental periods of 7 days, with intervening washout periods of at least 2 weeks. During each experimental period, the students rinsed only twice daily with different antiseptics. At day 7, morning breath was scored clinically (volatile sulphide compound [VSC] level and organoleptic ratings), and 1.5 ml of saliva was collected and divided between 3 glass tubes that were sealed and incubated (37 degrees C, anaerobic chamber). Immediately after collection and after 3 and 6 hours of incubation, the headspace air in one of the tubes was examined for VSC production and organoleptic measurements. The investigations of the incubated saliva correlated well with the 7-day intraoral VSC recordings and organoleptic ratings (P < or = 0.005). Moreover, evaluations showed a similar interproduct ranking for their efficacy in malodor control. The power analyses indicated a higher discrimination power for the saliva incubation test than for the intraoral registrations. The strong correlation between odor production of incubated saliva and clinical assessments suggests that the saliva incubation test may be used as an indirect method to measure oral malodor and can be employed to investigate the antimalodor effectiveness of oral hygiene products.

  9. Effectiveness of Surface Cleaning and Disinfection in a Brazilian Healthcare Facility

    PubMed Central

    Santos-Junior, Aires G.; Ferreira, Adriano M.; Frota, Oleci P.; Rigotti, Marcelo A.; Barcelos, Larissa da S.; Lopes de Sousa, Alvaro Francisco; de Andrade, Denise; Guerra, Odanir G.; R. Furlan, Mara C.

    2018-01-01

    Background: Failures in the processes of cleaning and disinfecting health service surfaces may result in the spread and transfer of pathogens that are often associated with healthcare-related infections and outbreaks. Aims: To assess the effectiveness of environmental surface cleaning and disinfection in a hospital clinic. Method: The study was conducted in a nursing ward with 45 beds. A total of 80 samples from five high-touch surfaces were evaluated before and after cleaning and disinfection, using the following methods: visual inspection, adenosine triphosphate bioluminescence assay, aerobic colony count, Staphylococcus aureus colony count, and evaluation of resistance to methicillin. The data analysis used nonparametric comparative and correlative tests to observe any differences in the pre- and post- cleaning and disinfection results for the surfaces assessed. Results: Effective cleaning and disinfection had a significant effect on only two surfaces when measured for the presence of adenosine triphosphate, the inner bathroom door handle (p=0.007) and the toilet bowl (p=0.01). When evaluated for Staphylococcus aureus colony count, the toilet flush handle also demonstrated a significant effect (p=0.04). Conclusion: The effectiveness of cleaning and disinfection of the surfaces tested was not satisfactory. An educational intervention is recommended for the cleaning and disinfection staff and the nursing team at the healthcare facility. Relevance to Clinical Practice: The data in the study revealed that daily hospital cleaning and disinfection in the sampled sites are not sufficient in medical and surgical wards. Hospital cleanliness must be reevaluated from the point of view of materials, such as an adequate supply of clean cloths, in addition to establishing more precise cleanliness protocols and accurate monitoring systems. PMID:29643951

  10. Evaluation of surface roughness of enamel after various bonding and clean-up procedures on enamel bonded with three different bonding agents: An in-vitro study

    PubMed Central

    Goel, Amit; Singh, Atul; Gupta, Tarun

    2017-01-01

    Background The purpose of this study was to analyze and compare the enamel surface roughness before bonding and after debonding, to find correlation between the adhesive remnant index and its effect on enamel surface roughness and to evaluate which clean-up method is most efficient to provide a smoother enamel surface. Material and Methods 135 premolars were divided into 3 groups containing 45 premolars in each group. Group I was bonded by using moisture insensitive primer, Group II by using conventional orthodontic adhesive and Group III by using self-etching primer. Each group was divided into 3 sub-groups on the basis of type of clean-up method applied i,e scaling followed by polishing, tungsten carbide bur and Sof-Lex disc. Enamel surface roughness was measured and compared before bonding and after clean-up. Results Evaluation of pre bonding and post clean-up enamel surface roughness (Ra value) with the t test showed that Post clean-up Ra values were greater than Pre bonding Ra values in all the groups except in teeth bonded with self-etching primer cleaned with Sof-Lex disc. Reliability of ARI score taken at different time interval tested with Kruskal Wallis test suggested that all the readings were reliable. Conclusions No clean-up procedure was able to restore the enamel to its original smoothness. Self-etching primer and Sof-Lex disc clean-up method combination restored the enamel surface roughness (Ra value) closest to its pre-treatment value. Key words:Enamel surface roughness, clean-up method, adhesive remnant index. PMID:28512535

  11. Occupational risk factors for hand dermatitis among professional cleaners in Spain.

    PubMed

    Mirabelli, Maria C; Vizcaya, David; Martí Margarit, Anna; Antó, Josep Maria; Arjona, Lourdes; Barreiro, Esther; Orriols, Ramon; Gimenez-Arnau, Ana; Zock, Jan-Paul

    2012-04-01

    Dermatitis is an important health outcome for workers whose jobs put them in contact with irritants or sensitizing agents. We conducted an analysis of data from the Epidemiological Study on the Risk of Asthma in Cleaning Workers 2 (EPIASLI2) to assess worksites and cleaning products as risk factors for hand dermatitis among professional cleaning workers. We distributed 4993 questionnaires to employees of 37 cleaning companies, and used data from 818 (16%) respondents who provided information about skin symptoms and cleaning-related exposures. We assessed associations between the frequencies of worksite and cleaning product exposures and a symptom-based definition of hand dermatitis among current cleaning workers (n = 693) and a comparison population (n = 125). Hand dermatitis was reported by 28% of current cleaning workers, versus 18% of the comparison population, and was associated with cleaning outdoor areas and schools, and the use of hydrochloric acid [prevalence ratio (PR) 1.92, 95% confidence interval (CI) 1.22-3.02] and dust mop products (PR 1.75, 95% CI 1.11-2.75). Professional cleaning workers may not be sufficiently protected from cutaneous disease at work. Future research should further investigate the roles of multiple product exposures and personal protective equipment. © 2012 John Wiley & Sons A/S.

  12. Recycle of radioactive scrap metal from the Oak Ridge Gaseous Diffusion Plant (K-25 Site)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Meehan, R.W.

    1997-02-01

    The scale of the metal available for reuse at the plant includes 22 million pounds of Ni, 17 million pounds of Al, 47 million pounds of copper, and 835 million pounds of steels. In addition there is a wide range of industrial equipment and other items of value. The author describes small bench scale and pilot plant scale efforts made at treating metal for decontamination and fabrication into cast stock or specialized containers for reuse within the DOE complex or release. These projects show that much of the material can be cleaned or chemically decontaminated to a level where itmore » can be free released to various markets. Of the remaining metals, much of it can be cast into products which can be absorbed within the DOE complex.« less

  13. The suitability of ultrafine coal as an industrial boiler fuel

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Barratt, D.J.; Roberts, P.T.

    1989-07-01

    Coal that was finely ground to a mean particle size of 12 /mu/m produced a hotter, shorter flame compared to normal pulverized fuel in a pilot scale combustor. Measurements indicated that, should this fuel be fired in an industrial boiler, the rate of ash deposition on the walls and convection tubes could be low, but that the thin ash deposits that were produced might be more highly insulating and would therefore require more frequent cleaning. A mathematical model, using reactivity and pyrolysis data measured in laboratory-scale apparatus, has been used to predict the heat release rate within a boiler. Thismore » would be sufficiently high to allow a premium-quality finely ground coal to be burned in many boilers originally designed for oil firing, provided that burner mixing patterns were optimized.« less

  14. KSC-08pd3746

    NASA Image and Video Library

    2008-11-19

    CAPE CANAVERAL, Fla. – At the Parachute Refurbishment Facility at NASA's Kennedy Space Center in Florida, a worker checks the parachute lines, recovered from sea after the launch of space shuttle Endeavour on the STS-126 mission, as they move into the 30,000-gallon washer. The parachutes are used to slow the descent of the solid rocket boosters that are jettisoned during liftoff. After washing, the monorail will move the parachutes into a huge dryer heated with 140-degree air at 13,000 cubic feet per minute. One pilot, one drogue and three main canopies per booster slow the booster’s fall from about 360 mph to 50 mph. After the chutes are cleaned and repaired, they must be carefully packed into their bags so they will deploy correctly the next time they are used. Photo credit: NASA/Jim Grossmann

  15. KSC-08pd3748

    NASA Image and Video Library

    2008-11-19

    CAPE CANAVERAL, Fla. – At the Parachute Refurbishment Facility at NASA's Kennedy Space Center in Florida, another parachute recovered from sea after the launch of space shuttle Endeavour on the STS-126 mission is unwound from a large turnstile. After their recovery, the parachutes are untangled, hung on a monorail system and transported into a 30,000-gallon washer and a huge dryer heated with 140-degree air at 13,000 cubic feet per minute. The parachutes are used to slow the descent of the solid rocket boosters that are jettisoned during liftoff. One pilot, one drogue and three main canopies per booster slow the booster’s fall from about 360 mph to 50 mph. After the chutes are cleaned and repaired, they must be carefully packed into their bags so they will deploy correctly the next time they are used. Photo credit: NASA/Jim Grossmann

  16. KSC-08pd3745

    NASA Image and Video Library

    2008-11-19

    CAPE CANAVERAL, Fla. – At the Parachute Refurbishment Facility at NASA's Kennedy Space Center in Florida, a worker checks the parachute lines suspended from the monorail system. The parachutes were recovered from sea after the launch of space shuttle Endeavour on the STS-126 mission The parachutes are used to slow the descent of the solid rocket boosters that are jettisoned during liftoff. The monorail will transport each parachute into a 30,000-gallon washer and a huge dryer heated with 140-degree air at 13,000 cubic feet per minute. One pilot, one drogue and three main canopies per booster slow the booster’s fall from about 360 mph to 50 mph. After the chutes are cleaned and repaired, they must be carefully packed into their bags so they will deploy correctly the next time they are used. Photo credit: NASA/Jim Grossmann

  17. Mature B-cell neoplasms in Chernobyl clean-up workers of 1986-1987: summary of cytomorphological and immunocytochemical study in 25 years after Chernobyl accident.

    PubMed

    Gluzman, D F; Sklyarenko, L M; Nadgornaya, V A; Zavelevich, M P

    2011-03-01

    The data on the verified cases of mature B-cell neoplasms (chronic lymphocytic leukemia - CLL, B-prolymphocytic leukemia, non-Hodgkin's lymphoma in leukemization phase and multiple myeloma - MM; 146 cases in total) in the consecutive group of Ukrainian clean-up workers within 10-25 years after Chernobyl accident are summarized. B-cell neoplasms represent the most prevalent group among all diagnosed neoplasms of hematopoietic and lymphoid tissues in clean-up worker patients under study (49.4%). MM percentage in the patients of Chernobyl clean-up worker group turned out to be significantly higher than in the patients of the general populations studied at the same period. While the percentage of B-CLL is similar in clean-up worker patients and patients of general population, the trend towards younger age of patients with mature B-cell neoplasms in clean-up worker group is evident. The current concepts on the possible association between mature B-cell neoplasms (mainly B-CLL) and radiation exposure are briefly outlined. Only the precise diagnosis of hematopoietic malignancies combining with large-scale analytical epidemiological studies with careful dose assessment and long-term follow-up may represent the basis for resolving the question whether mature B-cell neoplasms may be radiogenic.

  18. Assessment of test methods for evaluating effectiveness of cleaning flexible endoscopes.

    PubMed

    Washburn, Rebecca E; Pietsch, Jennifer J

    2018-06-01

    Strict adherence to each step of reprocessing is imperative to removing potentially infectious agents. Multiple methods for verifying proper reprocessing exist; however, each presents challenges and limitations, and best practice within the industry has not been established. Our goal was to evaluate endoscope cleaning verification tests with particular interest in the evaluation of the manual cleaning step. The results of the cleaning verification tests were compared with microbial culturing to see if a positive cleaning verification test would be predictive of microbial growth. This study was conducted at 2 high-volume endoscopy units within a multisite health care system. Each of the 90 endoscopes were tested for adenosine triphosphate, protein, microbial growth via agar plate, and rapid gram-negative culture via assay. The endoscopes were tested in 3 locations: the instrument channel, control knob, and elevator mechanism. This analysis showed substantial level of agreement between protein detection postmanual cleaning and protein detection post-high-level disinfection at the control head for scopes sampled sequentially. This study suggests that if protein is detected postmanual cleaning, there is a significant likelihood that protein will also be detected post-high-level disinfection. It also infers that a cleaning verification test is not predictive of microbial growth. Copyright © 2018 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  19. Tephra fall clean-up in urban environments

    NASA Astrophysics Data System (ADS)

    Hayes, Josh L.; Wilson, Thomas M.; Magill, Christina

    2015-10-01

    Tephra falls impact urban communities by disrupting transport systems, contaminating and damaging buildings and infrastructures, and are potentially hazardous to human health. Therefore, prompt and effective tephra clean-up measures are an essential component of an urban community's response to tephra fall. This paper reviews case studies of tephra clean-up operations in urban environments around the world, spanning 50 years. It identifies methods used in tephra clean-up and assesses a range of empirical relationships between level of tephra accumulation and clean-up metrics such as collected tephra volume, costs, and duration of operations. Results indicate the volume of tephra collected from urban areas is proportional to tephra accumulation. Urban areas with small tephra accumulations (1,000 m3/km2 or an average of 1 mm thickness) may collect < 1% of the total deposit, whereas urban areas which experience large accumulations (> 50,000 m3/km2 or an average of 50 mm thickness) remove up to 80%. This relationship can inform impact and risk assessments by providing an estimate of the likely response required for a given tephra fall. No strong relationship was found between tephra fall accumulation and clean-up cost or duration for urban environments which received one-off tephra falls, suggesting that these aspects of tephra fall clean-up operations are context specific. Importantly, this study highlights the advantage of effective planning for tephra clean-up and disposal in potentially exposed areas.

  20. Optimization of PECVD Chamber Cleans Through Fundamental Studies of Electronegative Fluorinated Gas Discharges.

    NASA Astrophysics Data System (ADS)

    Langan, John

    1996-10-01

    The predominance of multi-level metalization schemes in advanced integrated circuit manufacturing has greatly increased the importance of plasma enhanced chemical vapor deposition (PECVD) and in turn in-situ plasma chamber cleaning. In order to maintain the highest throughput for these processes the clean step must be as short as possible. In addition, there is an increasing desire to minimize the fluorinated gas usage during the clean, while maximizing its efficiency, not only to achieve lower costs, but also because many of the gases used in this process are global warming compounds. We have studied the fundamental properties of discharges of NF_3, CF_4, and C_2F6 under conditions relevant to chamber cleaning in the GEC rf reference cell. Using electrical impedance analysis and optical emission spectroscopy we have determined that the electronegative nature of these discharges defines the optimal processing conditions by controlling the power coupling efficiency and mechanisms of power dissipation in the discharge. Examples will be presented where strategies identified by these studies have been used to optimize actual manufacturing chamber clean processes. (This work was performed in collaboration with Mark Sobolewski, National Institute of Standards and Technology, and Brian Felker, Air Products and Chemicals, Inc.)

  1. Clean Energy Manufacturing Analysis Center. 2015 Research Highlights -- Carbon Fiber

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Das, Sujit

    2016-03-01

    CEMAC has conducted four major studies on the manufacturing of clean energy technologies. Three of these focused on the end product: solar photovoltaic modules, wind turbines, and automotive lithium-ion batteries. The fourth area focused on a key material for manufacturing clean energy technologies, carbon fiber.

  2. Laser versus scalpel cleaning of crustose lichens on granite

    NASA Astrophysics Data System (ADS)

    Rivas, T.; Pozo-Antonio, J. S.; López de Silanes, M. E.; Ramil, A.; López, A. J.

    2018-05-01

    This paper addresses the evaluation of the cleaning of crustose lichens developing on granite. The evaluation was performed considering the effectiveness of the cleanings and harmfulness exerted on the granite. The laser cleaning of lichen was compared with the most conventional procedure, scalpel. The combination of both procedures was also tested. The study, which was carried out with two different species of crustose lichen, was also focused on the influence of the intrinsic characteristics of the lichen on the effectiveness. The cleanings were evaluated by optic and electronic microscopies, FTIR and colour spectrophotometry. A previous characterization of the lichen and its interaction with the granite using those analytical techniques were also performed. The laser cleaning effectiveness depends on the coverage and the colour of the lichen; also, the prior mechanical weakening of the lichen by scalpel seemed to improve the laser cleaning. The darkest lichen was satisfactorily removed by laser and with the combined cleaning. Conversely, the lightest lichen was more difficult to extract with laser than the darkest lichen, being necessary to apply both methods sequentially. Despite laser and the combination of methods cleaned satisfactorily the surface, they were unable to eliminate the thalli into fissures.

  3. A study of blood contamination of Siqveland matrix bands.

    PubMed

    Lowe, A H; Bagg, J; Burke, F J T; MacKenzie, D; McHugh, S

    2002-01-12

    AIMS To use a sensitive forensic test to measure blood contamination of used Siqveland matrix bands following routine cleaning and sterilisation procedures in general dental practice. Sixteen general dental practices in the West of Scotland participated. Details of instrument cleaning procedures were recorded for each practice. A total of 133 Siqveland matrix bands were recovered following cleaning and sterilisation and were examined for residual blood contamination by the Kastle-Meyer test, a well-recognised forensic technique. Ultrasonic baths were used for the cleaning of 62 (47%) bands and retainers and the remainder (53%) were hand scrubbed prior to autoclaving. Overall, 21% of the matrix bands and 19% of the retainers gave a positive Kastle-Meyer test, indicative of residual blood contamination, following cleaning and sterilisation. In relation to cleaning method, 34% of hand-scrubbed bands and 32% of hand-scrubbed retainers were positive for residual blood by the Kastle-Meyer test compared with 6% and 3% respectively of ultrasonically cleaned bands and retainers (P < 0.001). If Siqveland matrix bands are re-processed in the assembled state, then adequate pre-sterilisation cleaning cannot be achieved reliably. Ultrasonic baths are significantly more effective than hand cleaning for these items of equipment.

  4. Plasma surface cleaning in a microwave plasma source

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tsai, C.C.; Nelson, W.D.; Haselton, H.H.

    1994-03-01

    A microwave electron cyclotron resonance (ECR) plasma source has been operated to produce reactive plasmas of oxygen and its mixture with argon. Aluminum samples (0.95 cm by 1.9 cm) were coated with thin films (<20 {mu}m in thickness) of Shell Vitrea oil and cleaned by using such reactive plasmas. The plasma cleaning was done in discharge conditions of microwave power up to 1300 W, radio frequency power up to 200 W, biased potential up to 400 V, gas pressures up to 5 mtorr, and operating time up to 35 min. The surface texture of the postcleaned samples has been examinedmore » visually. Mass loss of the samples after plasma cleaning was measured to estimate cleaning rates. Measured clean rates of low-pressure (0.5-mtorr) argon/oxygen plasmas were as high as 2.7 {mu}m/min. X-ray photoelectron spectroscopy (XPS) was used to determine cleanliness of the sample surfaces after plasma cleaning. The XPS study on polished samples confirmed the effectiveness of plasma cleaning in achieving atomic level of surface cleanliness. In this technical memorandum plasma properties, cleaning phenomena, and significant results are reported and discussed.« less

  5. Pilot-model analysis and simulation study of effect of control task desired control response

    NASA Technical Reports Server (NTRS)

    Adams, J. J.; Gera, J.; Jaudon, J. B.

    1978-01-01

    A pilot model analysis was performed that relates pilot control compensation, pilot aircraft system response, and aircraft response characteristics for longitudinal control. The results show that a higher aircraft short period frequency is required to achieve superior pilot aircraft system response in an altitude control task than is required in an attitude control task. These results were confirmed by a simulation study of target tracking. It was concluded that the pilot model analysis provides a theoretical basis for determining the effect of control task on pilot opinions.

  6. Automated Array Assembly Task In-depth Study of Silicon Wafer Surface Texturizing

    NASA Technical Reports Server (NTRS)

    Jones, G. T.; Chitre, S.; Rhee, S. S.; Allison, K. L.

    1979-01-01

    A low cost wafer surface texturizing process was studied. An investigation of low cost cleaning operations to clean residual wax and organics from the surface of silicon wafers was made. The feasibility of replacing dry nitrogen with clean dry air for drying silicon wafers was examined. The two stage texturizing process was studied for the purpose of characterizing relevant parameters in large volume applications. The effect of gettering solar cells on photovoltaic energy conversion efficiency is described.

  7. Asthma, chronic bronchitis, and exposure to irritant agents in occupational domestic cleaning: a nested case-control study.

    PubMed

    Medina-Ramón, M; Zock, J P; Kogevinas, M; Sunyer, J; Torralba, Y; Borrell, A; Burgos, F; Antó, J M

    2005-09-01

    Women employed in domestic cleaning are at increased risk for symptoms of obstructive lung disease, but the agents responsible are unknown. To investigate common tasks and products in occupational domestic cleaning in relation to respiratory morbidity. Case-control study in domestic cleaning women nested within a large population based survey of women aged 30-65 years; 160 domestic cleaning women with asthma symptoms, chronic bronchitis symptoms, or both and 386 without a history of respiratory symptoms were identified. Detailed exposures were evaluated for 40 cases who reported still having symptoms at the recruitment interview, and 155 controls who reported not having symptoms. All tasks performed and products used when cleaning houses were determined in a face-to-face interview. Lung function, methacholine challenge, and serum IgE testing were performed. Personal exposure measurements of airborne chlorine and ammonia were performed in a subsample. Associations between asthma, chronic bronchitis, and cleaning exposures were evaluated using multiple logistic regression analysis. Airborne chlorine (median level 0-0.4 ppm) and ammonia (0.6-6.4 ppm) were detectable during occupational domestic cleaning activities. Cases used bleach more frequently than controls; adjusted odds ratio (OR) for intermediate exposure was 3.3 (95% CI 0.9 to 11) and for high exposure 4.9 (1.5 to 15). Other independent associations included accidental inhalation of vapours and gases from cleaning agents and washing dishes. These associations were more pronounced for cases with asthma symptoms than for those with symptoms of chronic bronchitis, but were not related to sensitisation to common allergens. Asthma symptoms in domestic cleaning women are associated with exposure to bleach and possibly other irritant agents. The public health impact of the use of irritant cleaning products could be widespread since the use of these products is common both in the workplace and at home.

  8. The stigma of clean dieting and orthorexia nervosa.

    PubMed

    Nevin, Suzanne M; Vartanian, Lenny R

    2017-01-01

    Although the stigma of eating disorders such as anorexia has been well established, little is known about the social consequences of "clean dieting" and orthorexia nervosa. In two studies, we examined the social stigma of clean dieting and orthorexia. In Study 1, participants read a vignette describing a woman following a "clean" diet, a woman with anorexia, or a control target (minimal information about the individual). In Study 2, participants read a vignette describing a woman with orthorexia, a woman displaying identical orthorexic behaviors but without the orthorexia label, a woman with anorexia, or a control target. Participants then rated the target individual on a range of measures assessing stereotypes, emotions, and behavioral intentions toward the target. Study 1 found that the clean-dieting target was evaluated more negatively than the control target on some dimensions, but less negatively than the target with anorexia nervosa. Study 2 found that evaluations of the targets with orthorexia nervosa were more negative than evaluations of a control target, but did not differ from evaluations of the target with anorexia nervosa. Perceptions of the target's control over her behavior were associated with more positive evaluations (Studies 1 and 2), whereas perceptions of blame and responsibility for the condition were associated with more negative evaluations (Study 2). Overall, these findings highlight the potential negative social consequences of clean dieting and orthorexia nervosa, and point to perceptions of control and blame as potential mechanisms underlying the stigma of these conditions.

  9. Innovative technologies on fuel assemblies cleaning for sodium fast reactors: First considerations on cleaning process

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Simon, N.; Lorcet, H.; Beauchamp, F.

    2012-07-01

    Within the framework of Sodium Fast Reactor development, innovative fuel assembly cleaning operations are investigated to meet the GEN IV goals of safety and of process development. One of the challenges is to mitigate the Sodium Water Reaction currently used in these processes. The potential applications of aqueous solutions of mineral salts (including the possibility of using redox chemical reactions) to mitigate the Sodium Water Reaction are considered in a first part and a new experimental bench, dedicated to this study, is described. Anhydrous alternative options based on Na/CO{sub 2} interaction are also presented. Then, in a second part, amore » functional study conducted on the cleaning pit is proposed. Based on experimental feedback, some calculations are carried out to estimate the sodium inventory on the fuel elements, and physical methods like hot inert gas sweeping to reduce this inventory are also presented. Finally, the implementation of these innovative solutions in cleaning pits is studied in regard to the expected performances. (authors)« less

  10. Reducing health care-associated infections by implementing separated environmental cleaning management measures by using disposable wipes of four colors.

    PubMed

    Wong, Swee Siang; Huang, Cheng Hua; Yang, Chiu Chu; Hsieh, Yi Pei; Kuo, Chen Ni; Chen, Yi Ru; Chen, Li Ching

    2018-01-01

    Environmental cleaning is a fundamental principle of infection control in health care settings. We determined whether implementing separated environmental cleaning management measures in MICU reduced the density of HAI. We performed a 4-month prospective cohort intervention study between August and December 2013, at the MICU of Cathay General hospital. We arranged a training program for all the cleaning staff regarding separated environmental cleaning management measures by using disposable wipes of four colors to clean the patients' bedside areas, areas at a high risk of contamination, paperwork areas, and public areas. Fifteen high-touch surfaces were selected for cleanliness evaluation by using the adenosine triphosphate (ATP) bioluminescence test. Then data regarding HAI densities in the MICU were collected during the baseline, intervention, and late periods. A total of 120 ATP readings were obtained. The total number of clean high-touch surfaces increased from 13% to 53%, whereas that of unclean high-touch surface decreased from 47% to 20%. The densities of HAI were 14.32‰ and 14.90‰ during the baseline and intervention periods, respectively. The HAI density did not decrease after the intervention period, but it decreased to 9.07‰ during the late period. Implementing separated environmental cleaning management measures by using disposable wipes of four colors effectively improves cleanliness in MICU environments. However, no decrease in HAI density was observed within the study period. Considering that achieving high levels of hand-hygiene adherence is difficult, improving environmental cleaning is a crucial adjunctive measure for reducing the incidence of HAIs.

  11. SUPERFUND TREATABILITY CLEARINGHOUSE: SOIL STABILIZATION PILOT STUDY, UNITED CHROME NPL SITE PILOT STUDY AND HEALTH AND SAFETY PROGRAM, UNITED CHROME NPL SITE PILOT STUDY

    EPA Science Inventory

    This document is a project plan for a pilot study at the United Chrome NPL site, Corvallis, Oregon and includes the health and safety and quality assurance/quality control plans. The plan reports results of a bench-scale study of the treatment process as iieasured by the ...

  12. The successful of finite element to invent particle cleaning system by air jet in hard disk drive

    NASA Astrophysics Data System (ADS)

    Jai-Ngam, Nualpun; Tangchaichit, Kaitfa

    2018-02-01

    Hard Disk Drive manufacturing has faced very challenging with the increasing demand of high capacity drives for Cloud-based storage. Particle adhesion has also become increasingly important in HDD to gain more reliability of storage capacity. The ability to clean on surfaces is more complicated in removing such particles without damaging the surface. This research is aim to improve the particle cleaning in HSA by using finite element to develop the air flow model then invent the prototype of air cleaning system to remove particle from surface. Surface cleaning by air pressure can be applied as alternative for the removal of solid particulate contaminants that is adhering on a solid surface. These technical and economic challenges have driven the process development from traditional way that chemical solvent cleaning. The focus of this study is to develop alternative way from scrub, ultrasonic, mega sonic on surface cleaning principles to serve as a foundation for the development of new processes to meet current state-of-the-art process requirements and minimize the waste from chemical cleaning for environment safety.

  13. Comparison of washer-disinfector cleaning indicators: impact of temperature and cleaning cycle parameters.

    PubMed

    Alfa, Michelle J; Olson, Nancy

    2014-02-01

    Because automated instrument washer-disinfectors (WD) are widely used in health care to reprocess a variety of medical instruments, we developed a study to compare 3 cleaning indicators to determine whether they detected suboptimal temperature, time, enzymatic detergent, and fluid action in a washer-disinfector. The Miele WD was used for this comparison. One optimal cycle and 14 cycles with suboptimal enzymatic detergent, cleaning time, temperature, or inactive spray arms were evaluated. The cleaning indicators evaluated included the following: Pinnacle Monitor for Automated Enzymatic Cleaning Process (PNCL), Wash-Checks (WC), and TOSI. The scoring system for all 3 indicators was harmonized to a common scale. Soiled tweezers were included in each cycle evaluated. The PNCL, TOSI, and WC cleaning indicators showed significantly more failures at 40°C compared with 60°C (100% vs 0% for PNCL, 17% vs 0% for TOSI, and 60% vs 22% for WC, respectively). There were significantly more failures at suboptimal temperatures with a 2- versus 4-minute cycle (100% vs 0% for PNCL, 17% vs 0% for TOSI, and 17% vs 0% for WC, respectively, for 40°C cycles). Despite suboptimal cleaning cycles, all soiled tweezers looked clean. All 3 cleaning indicators responded to suboptimal WD conditions; however, the PNCL was the most affected by alterations in the cycle conditions evaluated. In simulated use testing, cleaning indicators provided a more sensitive audit tool compared with visual inspection of soiled instruments after automated cleaning. Copyright © 2014 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Mosby, Inc. All rights reserved.

  14. Commercial-scale demonstration of the Liquid Phase Methanol (LPMEOH{sup trademark}) process. Third quarterly report, 1996

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    The Liquid Phase Methanol (LPMEOH)(TM) demonstration project at King sport, Tennessee, is a $213.7 million cooperative agreement between the U.S. Department of Energy (DOE) and Air Products Liquid Phase Conversion Company, L. P. (the Partnership). A demonstration unit producing 80,000 gallons per day (260 TPD) of methanol is being designed and constructed at a site located at the Eastman Chemical Company (Eastman) complex in Kingsport. The Partnership will own and operate the facility for the four year demonstration period. This project is sponsored under the DOE`s Clean Coal Technology Program, and its primary objective is to `demonstrate the production ofmore » methanol using the LPMEOH(TM) Process in conjunction with an integrated coal gasification facility.` The project will also demonstrate the suitability of the methanol produced for use as a chemical feedstock or as a low-sulfur dioxide, low-nitrogen oxides alternative fuel in stationary and transportation applications. The project may also demonstrate the production of dimethyl ether (DME) as a mixed coproduct with methanol, if laboratory- and pilot-scale research and market verification studies show promising results. If implemented, the DME would be produced during the last six months of the four year demonstration period. The LPMEOH(TM) process is the product of a cooperative development effort by Air Products and the DOE in a program that started in 1981. It was successfully piloted at a 10-TPD rate in the DOE-owned experimental unit at Air Products` LaPorte, Texas, site. This demonstration project is the culmination of that extensive cooperative development effort.« less

  15. Vocational Home Economics Curriculum Guide for Occupational Home and Institutional Services.

    ERIC Educational Resources Information Center

    Dewald, Margaret R.

    The training program outlined in this guide focuses upon the development of students for gainful employment through a two-year course of study in home and institutional services. Instructional topics are provided in nine areas: orientation to home and institutional services, cleaning supplies and equipment, cleaning surfaces, cleaning clothes and…

  16. Coal-cleaning plant refuse characterization

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cavalet, J.R.; Torak, E.R.

    1985-06-01

    This report describes a study performed for the Electric Power Research Institute's Coal Cleaning Test Facility in Homer City, Pennsylvania. The purpose of the study was to design a standard methods for chemically and physically classifying refuse generated by physical coal cleaning and to construct a matrix that will accurately predict how a particular refuse will react to particular disposal methods - based solely on raw-coal characteristics and the process used to clean the coal. The value of such a classification system (which has not existed to this point) is the ability to design efficient and economical systems for disposingmore » of specific coal cleaning refuse. The report describes the project's literature search and a four-tier classification system. It also provides designs for test piles, sampling procedures, and guidelines for a series of experiments to test the classfication system and create an accurate, reliable predictive matrix. 38 refs., 39 figs., 35 tabs.« less

  17. Occupational deaths and injuries by the types of street cleaning process.

    PubMed

    Jeong, Byung Yong

    2017-03-01

    This study aims to obtain an overall picture of occupational injuries by the types of street cleaning process. Three hundred and fifty-four injured persons were analyzed in terms of the company size and details of the injured persons and accidents. Results show that 'roadway cleaning' was the most common type of cleaning process for injuries, followed by 'sidewalk cleaning,' 'going/returning to work by bike' and 'lifting/carrying.' The findings also show that most accidents which occur when 'going/returning to work by bike' are in the form of traffic accidents, while in other processes they happen most often in the form of slips. Most of the accidents related to 'lifting/carrying' affected workers in their 50s or younger while other processes had a large portion of injured persons in their 50s or older. The findings of this study can be used as baseline data for preventative policies.

  18. Contamination control and assay results for the Majorana Demonstrator ultra clean components

    NASA Astrophysics Data System (ADS)

    Christofferson, C. D.; Abgrall, N.; Alvis, S. I.; Arnquist, I. J.; Avignone, F. T.; Barabash, A. S.; Barton, C. J.; Bertrand, F. E.; Bode, T.; Bradley, A. W.; Brudanin, V.; Busch, M.; Buuck, M.; Caldwell, T. S.; Chan, Y.-D.; Chu, P.-H.; Cuesta, C.; Detwiler, J. A.; Dunagan, C.; Efremenko, Yu.; Ejiri, H.; Elliott, S. R.; Gilliss, T.; Giovanetti, G. K.; Green, M. P.; Gruszko, J.; Guinn, I. S.; Guiseppe, V. E.; Haufe, C. R.; Hehn, L.; Henning, R.; Hoppe, E. W.; Howe, M. A.; Keeter, K. J.; Kidd, M. F.; Konovalov, S. I.; Kouzes, R. T.; Lopez, A. M.; Martin, R. D.; Massarczyk, R.; Meijer, S. J.; Mertens, S.; Myslik, J.; O'Shaughnessy, C.; Othman, G.; Poon, A. W. P.; Radford, D. C.; Rager, J.; Reine, A. L.; Rielage, K.; Robertson, R. G. H.; Rouf, N. W.; Shanks, B.; Shirchenko, M.; Suriano, A. M.; Tedeschi, D.; Trimble, J. E.; Varner, R. L.; Vasilyev, S.; Vetter, K.; Vorren, K.; White, B. R.; Wilkerson, J. F.; Wiseman, C.; Xu, W.; Yakushev, E.; Yu, C.-H.; Yumatov, V.; Zhitnikov, I.; Zhu, B. X.

    2018-01-01

    The Majorana Demonstrator is a neutrinoless double beta decay experiment utilizing enriched Ge-76 detectors in 2 separate modules inside of a common solid shield at the Sanford Underground Research Facility. The Demonstrator has utilized world leading assay sensitivities to develop clean materials and processes for producing ultra-pure copper and plastic components. This experiment is now operating, and initial data provide new insights into the success of cleaning and processing. Post production copper assays after the completion of Module 1 showed an increase in U and Th contamination in finished parts compared to starting bulk material. A revised cleaning method and additional round of surface contamination studies prior to Module 2 construction have provided evidence that more rigorous process control can reduce surface contamination. This article describes the assay results and discuss further studies to take advantage of assay capabilities for the purpose of maintaining ultra clean fabrication and process design.

  19. SUPERFUND TREATABILITY CLEARINGHOUSE: PILOT STUDY OF ENCLOSED THERMAL SOIL AERATION FOR REMOVAL OF VOLATILE ORGANIC CONTAMINATION AT THE MCKIN SUPERFUND SITE

    EPA Science Inventory

    This paper reports on the results of a pilot study that treated vadose zone soil contaminated with VOCs in an enclosed thermal aeration system. The McKin site, an NPL site in Grey, Maine, was the location of the pilot study. The pilot study was chosen to demonstrate the viabili...

  20. Household cleaning products and the risk of allergic dermatitis: a prospective cohort study with primary-school children.

    PubMed

    Liu, X; Tan, L; Yu, I T S; Zhang, Z; Wong, C C-Y; Guo, C; Ho, K F; Lau, A P S; Yeoh, E K; Lee, A; Lao, X Q

    2018-04-01

    Household cleaning products are widely used by the public, but limited data have been obtained on whether their use induces allergic dermatitis in children. This study investigated the association between exposure to household cleaning products and allergic dermatitis in primary-school children. A prospective cohort study of Hong Kong primary-school children was conducted between 2012 and 2014. A baseline survey was administered to 1812 students who did not have allergic dermatitis. Information on respiratory symptoms, exposure to household chemical cleaning products and other topics was collected using a self-administered questionnaire. A cumulative chemical burden (CCB) score was calculated for each student by summing the duration of exposure to 14 chemical cleaning products. Principal component analysis was used to identify patterns in the use of these cleaning products. Logistic regression was performed to calculate relative risk (RR) with 95% confidence intervals (CIs) after adjusting for potential confounders. Eighty-nine (4.9%) of the students surveyed had dermatitis during the follow-up. However, exposure to individual chemical cleaning products was not found to be associated with the children's allergic dermatitis (all P > 0.05). In contrast to those in the lowest tertile, neither CCB scores in the middle tertile (RR: 1.16, 95% CI: 0.67 to 2.00) nor those in the highest tertile (RR: 1.24, 95% CI: 0.73 to 2.14) were significantly associated with the risk of allergic dermatitis. The adjusted RR for every 5-unit increment in CCB score was 1.01 (95% CI: 0.98 to 1.03). Four patterns of cleaning-product use were derived, but none were found to be associated with the risk of dermatitis (all P > 0.05). The use of household chemical cleaning products is not associated with the risk of dermatitis in primary-school children. © 2017 European Academy of Dermatology and Venereology.

  1. Contamination removal using various solvents and methodologies

    NASA Technical Reports Server (NTRS)

    Jeppsen, J. C.

    1989-01-01

    Critical and non-critical bonding surfaces must be kept free of contamination that may cause potential unbonds. For example, an aft-dome section of a redesigned solid rocket motor that had been contaminated with hydraulic oil did not appear to be sufficiently cleaned when inspected by the optically stimulated electron emission process (Con Scan) after it had been cleaned using a hand double wipe cleaning method. As a result, current and new cleaning methodologies as well as solvent capability in removing various contaminant materials were reviewed and testing was performed. Bonding studies were also done to verify that the cleaning methods used in removing contaminants provide an acceptable bonding surface. The removal of contaminants from a metal surface and the strength of subsequent bonds were tested using the Martin Marietta and double-wipe cleaning methods. Results are reported.

  2. Knowledge, attitudes, and practices regarding environmental cleaning among environmental service workers in Chinese hospitals.

    PubMed

    Ni, Kaiwen; Chen, Bingbing; Jin, Hui; Kong, Qingxin; Ni, Xiaoping; Xu, Hong

    2017-09-01

    We conducted a study using a face-to-face survey to assess knowledge, attitudes, and practices of environmental service workers (ESWs) concerning routine cleaning and disinfection at 3 tertiary hospitals in China. There were 115 (89.1%) respondents who agreed that environmental cleaning can contribute to keep patients safe, whereas 63 (48.8%) reported they were very willing to make cleaning practices better. Only 15 (11.6%) ESWs agreed they were in risk of nosocomial infections during daily cleaning. Our findings suggest that the level of ESWs' knowledge regarding cleaning practices was passable, but the awareness of occupational safety and health was weak. There is a need to introduce sustained education and training aimed at ESWs. Copyright © 2017 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  3. Evaluation of fog and rain water collected at Delta Barrage, Egypt as a new resource for irrigated agriculture

    NASA Astrophysics Data System (ADS)

    Salem, Talaat A.; Omar, Mohie El Din M.; El Gammal, H. A. A.

    2017-11-01

    Alternative clean water resources are needed in Egypt to face the current water shortage and water quality deterioration. Therefore, this research investigates the suitability of harvesting fog and rain water for irrigation using a pilot fog collector for water quantity, water quality, and economic aspects. A pilot fog collector was installed at one location at Delta Barrage, Egypt. Freeze liquid nitrogen was fixed at the back of the fiberglass sheet to increase the condensation rate. The experiment was conducted during the period from November 2015 to February 2016. In general, all physicochemical variables are observed with higher values in the majority of fog than rain water. The fog is assumed to contain higher concentrations of anthropogenic emissions. TDS in both waters collected are less than 700 mg/l at sodium content less than 60%, classifying these waters as good for various plants under most conditions. In addition, SAR calculated values are less than 3.0 in each of fog and rain water, which proves the water suitability for all irrigated agriculture. Al and Fe concentrations were found common in all samples with values less than the permissible limits of the guidelines. These metals originate from soil material, ash and metal surfaces. The sensitive heavy metals (Cd and Pb) were within the permissible limits of the guideline in fog water, indicating this water is suitable for irrigation. On the contrary, rain water that has heavy metals is not permitted in irrigation water as per the Egyptian law. As per WQI, the rain water is classified as good quality while fog is classified as medium quality. Regarding the water quantity, a significant increase in the harvested fog quantity was observed after cooling the collector surface with freeze liquid nitrogen. The current fog collector produced the lowest water quantity among different fog collectors worldwide. However, these comparative results confirmed that quantity is different from one location to another worldwide even in the same country. The cost of the unit water volume of harvested water by the current pilot collector is relatively low among different collectors worldwide. This study proves that fog harvesting in Egypt is feasible using the current pilot collector in terms of water quantity, water quality, and economy. But it recommends collection of fog at various locations and times, since both water quantity and water quality are variable in time and space. It is more or less viable solution to meet the shortage of water in Egypt.

  4. Patent foramen ovale and asymptomatic brain lesions in military fighter pilots.

    PubMed

    Kang, Kyung Wook; Kim, Joon-Tae; Choi, Won-Ho; Park, Won-Ju; Shin, Young Ho; Choi, Kang-Ho

    2014-10-01

    Previous studies have reported higher incidence of white matter lesions (WMLs) in military pilots. The anti-gravity straining maneuver, which fighter military pilots perform numerously during a flight is identical to the valsalva maneuver. We sought to investigate the prevalence of right-to-left shunt (RLS) associated with WMLs in military pilots. A prospective study was performed involving military pilots who visited the Airomedical Center. The pilots underwent brain magnetic resonance imaging (MRI) scan and transcranial Doppler (TCD) with intravenous injection of agitated saline solution for the detection of RLS. Periventricular WMLs (PVWMLs) on MRI were graded using Fazeka's scale, and deep WMLs (DWMLs) were graded using Scheltens's scale. This study included 81 military pilots. RLS on TCD was observed less frequently in non-fighter pilots than in fighter pilots (35.5% vs. 64.5%, p=0.011). Fighter pilot was an independently associated factor with RLS on the TCD. DWMLs were independently associated with RLSs through a patent foramen ovale (PFO) (OR 3.507, 95% CI 1.223-10.055, p=0.02). The results suggest that DWMLs in military pilots may significantly be associated with RLS via PFO. Additional investigations are warranted. Copyright © 2014 Elsevier B.V. All rights reserved.

  5. The impact of home cleaning on quality of life for homes with asthmatic children.

    PubMed

    Barnes, Charles S; Kennedy, Kevin; Gard, Luke; Forrest, Erika; Johnson, Linda; Pacheco, Freddy; Hu, Frank; Amado, Mercedes; Portnoy, Jay M

    2008-01-01

    Treatment with common household bleach containing hypochlorite destroys dust mites and denatures protein allergens. The purpose of this study was to determine if home use of hypochlorite products results in lowered exposure to bacteria, fungi, and protein allergens and improved quality of life (QOL) for asthmatic persons in the home. Asthmatic and nonasthmatic households containing at least three persons (between 2 and 17 years of age) were recruited. Households were supplied one of three sets of cleaning products (regular products, some containing hypochlorite; regular products plus three additional products with dilute hypochlorite; control, no products). Participants were supplied with cleaning instructions and asthma education. The control group was instructed to clean as usual. Participants completed general health and QOL questionnaires. Asthmatic participants completed an additional asthma QOL questionnaire. Families participated in the study for 8 weeks and completed the full set of questions every 2 weeks. Homes were visited at the beginning of the study and twice thereafter at monthly intervals. Samples evaluated were surface bacteria, viable and nonviable airborne spores, and dust antigen content. Reductions in surface bacteria, airborne fungal spores, and dust antigen levels were achieved. Significant improvement in general health parameters was seen for the asthmatic product groups over the control group. Significant improvement in general QOL and asthma-specific QOL was seen in the asthmatic group. Emphasis on cleaning and cleaning education combined with hypochlorite-based cleaning supplies resulted in significantly improved QOL for families with asthmatic children.

  6. Cleaning the grey zones of hospitals: A prospective, crossover, interventional study.

    PubMed

    Semret, Makeda; Dyachenko, Alina; Ramman-Haddad, Leila; Belzile, Eric; McCusker, Jane

    2016-12-01

    Environmental cleaning is a fundamental principle of infection prevention in hospitals, but its role in reducing transmission of health care-acquired pathogens has been difficult to prove experimentally. In this study we analyze the influence of cleaning previously uncleaned patient care items, grey zones (GZ), on health care-acquired transmission rates. The intervention consisted of specific GZ cleaning by an extra cleaner (in addition to routine cleaning) on 2 structurally different acute care medical wards for a period of 6 months each, in a crossover design. Data on health care-acquired transmissions of vancomycin-resistant enterococci (VRE), methicillin-resistant Staphylococcus aureus, and Clostridium difficile were collected during both periods. Adjusted incidence rate ratios (IRRs) using Poisson regression were calculated to compare transmission of pathogens between both periods on both wards. During the intervention VRE transmission was significantly decreased (2-fold) on the ward where patients had fewer roommates; cleaning of GZ did not have any effect on the ward with multiple-occupancy rooms. There was no impact on methicillin-resistant S aureus transmission and only a nonsignificant decrease in transmission of C difficile. Our data provide evidence that targeted cleaning interventions can reduce VRE transmission when rooming conditions are optimized; such interventions can be cost-effective when the burden of VRE is significant. Enhanced cleaning interventions are less beneficial in the context of room sharing where many other factors contribute to transmission of pathogens. Crown Copyright © 2016. Published by Elsevier Inc. All rights reserved.

  7. Cleaning, disinfection and sterilization of surface prion contamination.

    PubMed

    McDonnell, G; Dehen, C; Perrin, A; Thomas, V; Igel-Egalon, A; Burke, P A; Deslys, J P; Comoy, E

    2013-12-01

    Prion contamination is a risk during device reprocessing, being difficult to remove and inactivate. Little is known of the combined effects of cleaning, disinfection and sterilization during a typical reprocessing cycle in clinical practice. To investigate the combination of cleaning, disinfection and/or sterilization on reducing the risk of surface prion contamination. In vivo test methods were used to study the impact of cleaning alone and cleaning combined with thermal disinfection and high- or low-temperature sterilization processes. A standardized test method, based on contamination of stainless steel wires with high titres of scrapie-infected brain homogenates, was used to determine infectivity reduction. Traditional chemical methods of surface decontamination against prions were confirmed to be effective, but extended steam sterilization was more variable. Steam sterilization alone reduced the risk of prion contamination under normal or extended exposure conditions, but did show significant variation. Thermal disinfection had no impact in these studies. Cleaning with certain defined formulations in combination with steam sterilization can be an effective prion decontamination process, in particular with alkaline formulations. Low-temperature, gaseous hydrogen peroxide sterilization was also confirmed to reduce infectivity in the presence and absence of cleaning. Prion decontamination is affected by the full reprocessing cycle used on contaminated surfaces. The correct use of defined cleaning, disinfection and sterilization methods as tested in this report in the scrapie infectivity assay can provide a standard precaution against prion contamination. Copyright © 2013 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  8. Removal of biofilm from contact lens storage cases.

    PubMed

    Wu, Yvonne T; Zhu, Hua; Willcox, Mark; Stapleton, Fiona

    2010-12-01

    Lens case hygiene practices are important in maintaining safe contact lens wear. However, the effectiveness of various lens case cleaning practices have not been evaluated and compared. This in vitro study aimed to evaluate and compare the efficacy of cleaning practices that are most commonly carried out by lens wearers and recommended by practitioners. Pseudomonas aeruginosa 122, Serratia marcescens ATCC 13880, and Staphylococcus aureus ATCC 6538 were the challenge bacteria for biofilm formation on unused lens cases from two different manufacturers. After establishment of the biofilm, each lens case was subjected to one of the six cleaning regimens: "rinsed," "rubbed and rinsed," "air-dried," "soaked in a multipurpose contact lens solution," "tissue-wiped," and "lids recapped." The level of residual biofilm was quantified at the end of each cleaning regimen. The efficacy of each cleaning regimen was then compared. Mechanical rubbing and wiping of lens cases were the most effective cleaning regimen tested in reducing biofilm. Soaking lenses in disinfecting solution for 6 hours removed the majority of biofilm from lens cases. Rinsing lens cases alone provided only minimal efficacy in reducing biofilm. Air-drying or recapping the cases with the lid without any other additional cleaning methods were the least efficient at removing biofilm. Based on this study, digital rubbing and rinsing and/or wiping the lens cases with tissue is recommended. Air-drying or recapping the lens case lids after use without any additional cleaning methods should be discouraged with non-antimicrobial lens cases.

  9. Measuring the effect of enhanced cleaning in a UK hospital: a prospective cross-over study.

    PubMed

    Dancer, Stephanie J; White, Liza F; Lamb, Jim; Girvan, E Kirsty; Robertson, Chris

    2009-06-08

    Increasing hospital-acquired infections have generated much attention over the last decade. There is evidence that hygienic cleaning has a role in the control of hospital-acquired infections. This study aimed to evaluate the potential impact of one additional cleaner by using microbiological standards based on aerobic colony counts and the presence of Staphylococcus aureus including meticillin-resistant S. aureus. We introduced an additional cleaner into two matched wards from Monday to Friday, with each ward receiving enhanced cleaning for six months in a cross-over design. Ten hand-touch sites on both wards were screened weekly using standardised methods and patients were monitored for meticillin-resistant S. aureus infection throughout the year-long study. Patient and environmental meticillin-resistant S. aureus isolates were characterised using molecular methods in order to investigate temporal and clonal relationships. Enhanced cleaning was associated with a 32.5% reduction in levels of microbial contamination at hand-touch sites when wards received enhanced cleaning (P < 0.0001: 95% CI 20.2%, 42.9%). Near-patient sites (lockers, overbed tables and beds) were more frequently contaminated with meticillin-resistant S. aureus/S. aureus than sites further from the patient (P = 0.065). Genotyping identified indistinguishable strains from both hand-touch sites and patients. There was a 26.6% reduction in new meticillin-resistant S. aureus infections on the wards receiving extra cleaning, despite higher meticillin-resistant S. aureus patient-days and bed occupancy rates during enhanced cleaning periods (P = 0.032: 95% CI 7.7%, 92.3%). Adjusting for meticillin-resistant S. aureus patient-days and based upon nine new meticillin-resistant S. aureus infections seen during routine cleaning, we expected 13 new infections during enhanced cleaning periods rather than the four that actually occurred. Clusters of new meticillin-resistant S. aureus infections were identified 2 to 4 weeks after the cleaner left both wards. Enhanced cleaning saved the hospital 30,000 pounds to 70,000 -pounds. Introducing one extra cleaner produced a measurable effect on the clinical environment, with apparent benefit to patients regarding meticillin-resistant S. aureus infection. Molecular epidemiological methods supported the possibility that patients acquired meticillin-resistant S. aureus from environmental sources. These findings suggest that additional research is warranted to further clarify the environmental, clinical and economic impact of enhanced hygienic cleaning as a component in the control of hospital-acquired infection.

  10. Structural Break, Stock Prices of Clean Energy Firms and Carbon Market

    NASA Astrophysics Data System (ADS)

    Wang, Yubao; Cai, Junyu

    2018-03-01

    This paper uses EU ETS carbon future price and Germany/UK clean energy firms stock indices to study the relationship between carbon market and clean energy market. By structural break test, it is found that the ‘non-stationary’ variables judged by classical unit root test do own unit roots and need taking first difference. After analysis of VAR and Granger causality test, no causal relationships are found between the two markets. However, when Hsiao’s version of causality test is employed, carbon market is found to have power in explaining the movement of stock prices of clean energy firms, and stock prices of clean energy firms also affect the carbon market.

  11. Expertise and responsibility effects on pilots' reactions to flight deck alerts in a simulator.

    PubMed

    Zheng, Yiyuan; Lu, Yanyu; Yang, Zheng; Fu, Shan

    2014-11-01

    Flight deck alerts provide system malfunction information designed to lead corresponding pilot reactions aimed at guaranteeing flight safety. This study examined the roles of expertise and flight responsibility and their relationship to pilots' reactions to flight deck alerts. There were 17 pilots composing 12 flight crews that were assigned into pairs according to flight hours and responsibilities. The experiment included 9 flight scenarios and was carried out in a CRJ-200 flight simulator. Pilot performance was recorded by a wide angle video camera, and four kinds of reactions to alerts were defined for analysis. Pilots tended to have immediate reactions to uninterrupted cautions, with a turning off rate as high as 75%. However, this rate decreased sharply when pilots encountered interrupted cautions and warnings; they also exhibited many wrong reactions to warnings. Pilots with more expertise had more reactions to uninterrupted cautions than those with less expertise, both as pilot flying and pilot monitoring. Meanwhile, the pilot monitoring, regardless of level of expertise, exhibited more reactions than the pilot flying. In addition, more experienced pilots were more likely to have wrong reactions to warnings while acting as the monitoring pilot. These results suggest that both expertise and flight responsibility influence pilots' reactions to alerts. Considering crew pairing strategy, when a pilot flying is a less experienced pilot, a more experience pilot is suggested to be the monitoring pilot. The results of this study have implications for understanding pilots' behaviors to flight deck alerts, calling for specialized training and design of approach alarms on the flight deck.

  12. Human factors in aviation crashes involving older pilots.

    PubMed

    Li, Guohua; Baker, Susan P; Lamb, Margaret W; Grabowski, Jurek G; Rebok, George W

    2002-02-01

    Pilot errors are recognized as a contributing factor in as many as 80% of aviation crashes. Experimental studies using flight simulators indicate that due to decreased working memory capacity, older pilots are outperformed by their younger counterparts in communication tasks and flight summary scores. This study examines age-related differences in crash circumstances and pilot errors in a sample of pilots who flew commuter aircraft or air taxis and who were involved in airplane or helicopter crashes. A historical cohort of 3306 pilots who in 1987 flew commuter aircraft or air taxis and were 45-54 yr of age was constructed using the Federal Aviation Administration's airmen information system. Crash records of the study subjects for the years 1983-1997 were obtained from the National Transportation Safety Board (NTSB) by matching name and date of birth. NTSB's investigation reports were reviewed to identify pilot errors and other contributing factors. Comparisons of crash circumstances and human factors were made between pilots aged 40-49 yr and pilots aged 50-63 yr. A total of 165 crash records were studied, with 52% of these crashes involving pilots aged 50-63 yr. Crash circumstances, such as time and location of crash, type and phase of flight, and weather conditions, were similar between the two age groups. Pilot error was a contributing factor in 73% of the crashes involving younger pilots and in 69% of the crashes involving older pilots (p = 0.50). Age-related differences in the pattern of pilot errors were statistically insignificant. Overall, 23% of pilot errors were attributable to inattentiveness, 20% to flawed decisions, 18% to mishandled aircraft kinetics, and 18% to mishandled wind/runway conditions. Neither crash circumstances nor the prevalence and patterns of pilot errors appear to change significantly as age increases from the 40s to the 50s and early 60s.

  13. OPERATING THE WAND AND HERCULES PROTOTYPE SYSTEMS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    K. GRUETZMACHER; ET AL

    2001-01-01

    Two prototype systems for low-density Green is Clean (GIC) waste at Los Alamos National Laboratory (LANL) have been in operation for three years at the Solid Waste Operation's (SWOs) non-destructive assay (NDA) building. The Waste Assay for Nonradioactive Disposal (WAND) and the High Efficiency Radiation Counters for Ultimate Low Emission Sensitivity (HERCULES) are used to verify the waste generator's acceptable knowledge (AK) that low-density waste is nonradioactive. GIC waste includes all non-regulated waste generated in radiological controlled areas (RCAs) that has been actively segregated as ''clean'' (i.e., nonradioactive) through the use of waste generator AK. GIC waste that is verifiedmore » clean can be disposed of at the Los Alamos County Landfill. It is estimated that 50-90% of the low-density room trash from RCAs at LANL might be free of contamination. To date, with pilot programs at five facilities at LANL, 3000 cubic feet of GIC waste has been verified clean by these two prototype systems. Both the WAND and HERCULES systems are highly sensitive measurement systems optimized to detect very small quantities of common LANL radionuclides. Both of the systems use a set of phoswich scintillation detectors in close proximity to the waste, which have the capability of detecting plutonium-239 concentrations below 3 pCi per gram of low density waste. Both systems detect low-energy x-rays and a broad range of gamma rays (10-2000 keV), while the WAND system also detects high energy beta particles (>100 keV). The WAND system consists of a bank of six shielded detectors which screen low density shredded waste or stacked sheets of paper moving under the detectors in a twelve inch swath on a conveyor belt. The WAND system was developed and tested at the Los Alamos Plutonium Facility in conjunction with instrument system designers from the Los Alamos Safeguards Science and Technology group. The HERCULES system consists of a bank of three shielded detectors which screen low-density waste in two cubic foot cardboard boxes or in bags sitting on a turntable. Waste that does not pass the verification process can be examined within the facility to determine the type and quantity of the contamination and its origin within a waste container. The paper discusses lessons learned that have helped generators improve their AK segregation.« less

  14. LHC Abort Gap Cleaning Studies During Luminosity Operation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gianfelice-Wendt, E.; /Fermilab; Bartmann, W.

    2012-05-11

    The presence of significant intensities of un-bunched beam is a potentially serious issue in the LHC. Procedures using damper kickers for cleaning both the Abort Gap (AG) and the buckets targeted for injection, are currently in operation at flat bottom. Recent observations of relatively high population of the AG during physics runs brought up the need for AG cleaning during luminosity operation. In this paper the results of experimental studies performed in October 2011 are presented.

  15. Fouling of a spiral-wound reverse osmosis membrane processing swine wastewater: effect of cleaning procedure on fouling resistance.

    PubMed

    Camilleri-Rumbau, M S; Masse, L; Dubreuil, J; Mondor, M; Christensen, K V; Norddahl, B

    2016-01-01

    Swine manure is a valuable source of nitrogen, phosphorus and potassium. After solid-liquid separation, the resulting swine wastewater can be concentrated by reverse osmosis (RO) to produce a nitrogen-potassium rich fertilizer. However, swine wastewater has a high fouling potential and an efficient cleaning strategy is required. In this study, a semi-commercial farm scale RO spiral-wound membrane unit was fouled while processing larger volumes of swine wastewater during realistic cyclic operations over a 9-week period. Membrane cleaning was performed daily. Three different cleaning solutions, containing SDS, SDS+EDTA and NaOH were compared. About 99% of the fouling resistance could be removed by rinsing the membrane with water. Flux recoveries (FRs) above 98% were achieved for all the three cleaning solutions after cleaning. No significant differences in FR were found between the cleaning solutions. The NaOH solution thus is a good economical option for cleaning RO spiral-wound membranes fouled with swine wastewater. Soaking the membrane for 3 days in permeate water at the end of each week further improved the FR. Furthermore, a fouling resistance model for predicting the fouling rate, permeate flux decay and cleaning cycle periods based on processing time and swine wastewater conductivity was developed.

  16. Assessment of the potential suitability of selected commercially available enzymes for cleaning-in-place (CIP) in the dairy industry.

    PubMed

    Boyce, Angela; Piterina, Anna V; Walsh, Gary

    2010-10-01

    The potential suitability of 10 commercial protease and lipase products for cleaning-in-place (CIP) application in the dairy industry was investigated on a laboratory scale. Assessment was based primarily on the ability of the enzymes to remove an experimentally generated milk fouling deposit from stainless steel (SS) panels. Three protease products were identified as being most suitable for this application on the basis of their cleaning performance at 40 °C, which was comparable to that of the commonly used cleaning agent, 1% NaOH at 60 °C. This was judged by quantification of residual organic matter and protein on the SS surface after cleaning and analysis by laser scanning confocal microscopy (LSCM). Enzyme activity was removed/inactivated under conditions simulating those normally undertaken after cleaning (rinsing with water, acid circulation, sanitation). Preliminary process-scale studies strongly suggest that enzyme-based CIP achieves satisfactory cleaning at an industrial scale. Cost analysis indicates that replacing caustic-based cleaning procedures with biodegradable enzymes operating at lower temperatures would be economically viable. Additional potential benefits include decreased energy and water consumption, improved safety, reduced waste generation, greater compatibility with wastewater treatment processes and a reduction in the environmental impact of the cleaning process.

  17. Manual versus automated methods for cleaning reusable accessory devices used for minimally invasive surgical procedures.

    PubMed

    Alfa, M J; Nemes, R

    2004-09-01

    We undertook a simulated-use study using quantitative methods to evaluate the cleaning efficacy of ported and non-ported accessory devices used in minimally invasive surgery. We chose laparoscopic scissors and forceps to represent worst-case devices which were inoculated with artificial test soil containing 10(6) cfu/mL Enterococcus faecalis and Geobacillus stearothermophilus and allowed to dry for 1 h. Cleaning was performed manually, as well as by the automated SI-Auto Narrow lumen cleaner. Manual cleaning left two- to 50-fold more soil residuals (protein, haemoglobin and carbohydrate) inside the lumen of non-ported versus ported laparoscopic accessory devices. The SI-Auto Narrow lumen cleaner was more efficient than manual cleaning and achieved >99% reduction in soil parameters in both non-ported (using retro-flushing) and ported laparoscopic devices. Only the automated cleaning of ported devices achieved 10(3)-10(4)-fold reduction in bacterial numbers. Sonication alone (no flushing of inner channel) did not effectively remove soil or organisms from the inner channel. Our findings indicate that non-ported accessory devices cannot be as reliably cleaned as ported devices regardless of the cleaning method used. If non-ported accessory devices are reprocessed, they should be cleaned using retro-flushing in an automated narrow lumen cleaner.

  18. Plutonium mining for cleanup.

    PubMed

    Bramlitt, E T

    1988-08-01

    Cleanup is the act of making a contaminated site relatively free of Pu so it may be used without radiological safety restrictions. Contaminated ground is the focus of major cleanups. Cleanup traditionally involves determining Pu content of soil, digging up soil in which radioactivity exceeds guidelines, and relocating excised soil to a waste-disposal site. Alternative technologies have been tested at Johnston Atoll (JA), where there is as much as 100,000 m3 of Pu-contaminated soil. A mining pilot plant operated for the first 6 mo of 1986 and made 98% of soil tested "clean", from more than 40 kBq kg-1 (1000 pCi g-1) to less than about 500 Bq kg-1 (15 pCi g-1) by concentrating Pu in 2% of the soil. The pilot plant is now installed at the U.S. Department of Energy Nevada Test Site for evaluating cleanup of other contaminated soils and refining cleanup effectiveness. A full-scale cleanup plant has been programmed for JA in 1988. In this paper, previous cleanups are reviewed, and the mining endeavor at JA is detailed. "True soil cleanup" is contrasted with the classical "soil relocation cleanup." The mining technology used for Pu cleanup has been in use for more than a century. Mining for cleanup, however, is unique. It is envisioned as being prominent for radiological and other cleanups in the future.

  19. EPA's National Coastal Condition Assessment: Pilot research ...

    EPA Pesticide Factsheets

    The EPA Office of Water’s 5-year cycles of national surveys of wetlands, lakes, rivers, and coastal areas help satisfy the assessment and antidegradation provisions of the Clean Water Act. Measuring extant conditions precedes measuring change in conditions. Surveys are challenged to adequately sample extreme conditions occurring in small areas. Extremely bad conditions are targets for remediation. Extremely good conditions are targets for protection. In 2010, the National Coastal Condition Assessment (NCCA) found the majority of the coastal Great Lakes (by area) was in good condition for water (60%) and sediment (51%) quality but not benthos (20%) and fish tissue contaminants (<1%). Low sampling success for biological sampling was an issue. As part of the 2014 Lake Erie CSMI field year, EPA’s Great Lakes National Program Office, working with the Office of Research and Development, began pilot research to integrate connecting channels into Great Lakes surveys. Assessments of the Huron-Erie corridor (HEC; 2014, 2015) and St Marys River (SMR; 2015, 2016) which have previously gone unassessed by NCCA, are being developed. Water, sediment, and benthic quality data from the 2014 HEC survey (n=60) were compared to 2010 NCCA data from adjacent lakes. Water quality rated “poor” (as % area) in HEC was intermediate compared to Lake Huron and Erie regardless of which lake-specific thresholds were used. However, the amount of area classified as “good” was highl

  20. Microbial diversity in European and South American spacecraft assembly clean rooms

    NASA Astrophysics Data System (ADS)

    Moissl-Eichinger, Christine; Stieglmeier, Michaela; Schwendner, Petra

    Spacecraft assembly clean rooms are unique environments for microbes: Due to low nutri-ent levels, desiccated, clean conditions, constant control of humidity and temperature, these environments are quite inhospitable to microbial life and even considered "extreme". Many procedures keep the contamination as low as possible, but these conditions are also highly se-lective for indigenous microbial communities. For space missions under planetary protection requirements, it is crucial to control the contaminating bioburden as much as possible; but for the development of novel cleaning/sterilization methods it is also important to identify and characterize (understand) the present microbial community of spacecraft clean rooms. In prepa-ration for the recently approved ESA ExoMars mission, two European and one South American spacecraft assembly clean rooms were analyzed with respect to their microbial diversity, using standard procedures, new cultivation approaches and molecular methods, that should shed light onto the presence of planetary protection relevant microorganisms. For this study, the Her-schel Space Observatory (launched in May 2009) and its housing clean rooms in Friedrichshafen (Germany), at ESTEC (The Netherlands) and CSG, Kourou (French Guyana) were sampled during assembly, test and launch operations. Although Herschel does not demand planetary protection requirements, all clean rooms were in a fully operating state during sampling. This gave us the opportunity to sample the microbial diversity under strict particulate and molecular contamination-control. Samples were collected from spacecraft and selected clean room surface areas and were subjected to cultivation assays (32 different media), molecular studies (based on 16S rRNA gene sequence analysis) and quantitative PCR. The results from different strategies will be compared and critically discussed, showing the advantages and limits of the selected methodologies. This talk will sum up the lessons learned from this microbial diversity project.

  1. Observations on Salmonella contamination of commercial duck farms before and after cleaning and disinfection.

    PubMed

    Martelli, Francesca; Gosling, Rebecca J; Callaby, Rebecca; Davies, Rob

    2017-04-01

    In the European Union, statutory control of Salmonella is in place in the chicken and turkey sectors, but not in the duck sector. In this study, 14 Salmonella-positive duck farms were sampled before and after cleaning and disinfection, and once the houses had been restocked with a new flock. The cleaning and disinfection programmes used were subdivided into two main categories: ones in which a final formaldehyde disinfection step was included (1) and ones in which it was not included (2). Several types of samples were collected during the study, and faecal samples were those more frequently positive (62% of faecal samples were positive for Salmonella in comparison to 2-23% of samples from all the other sample categories) (P < 0.001). Independently of the cleaning and disinfection programme used, there was a statistically significant (P < 0.001) reduction in the percentage of Salmonella-positive samples between before cleaning and disinfection (41.1%) and after cleaning and disinfection (3.1%). After restocking, the number of Salmonella-positive samples increased significantly (P < 0.001), with 65.3% of the samples tested being positive for Salmonella. Farms in which disinfection programme 1 was used were 5.34 times less likely to have samples positive for Salmonella after cleaning and disinfection than farms which implemented programme 2. Formaldehyde acts effectively against Salmonella even in the presence of some residual organic matter. Limited residual contamination on farms after cleaning and disinfection represents a risk of infection for young ducklings, and thorough cleaning and disinfection procedures should be implemented to reduce the carry-over of infection between flocks.

  2. The psychophysiological assessment method for pilot's professional reliability.

    PubMed

    Zhang, L M; Yu, L S; Wang, K N; Jing, B S; Fang, C

    1997-05-01

    Previous research has shown that a pilot's professional reliability depends on two relative factors: the pilot's functional state and the demands of task workload. The Psychophysiological Reserve Capacity (PRC) is defined as a pilot's ability to accomplish additive tasks without reducing the performance of the primary task (flight task). We hypothesized that the PRC was a mirror of the pilot's functional state. The purpose of this study was to probe the psychophysiological method for evaluating a pilot's professional reliability on a simulator. The PRC Comprehensive Evaluating System (PRCCES) which was used in the experiment included four subsystems: a) quantitative evaluation system for pilot's performance on simulator; b) secondary task display and quantitative estimating system; c) multiphysiological data monitoring and statistical system; and d) comprehensive evaluation system for pilot PRC. Two studies were performed. In study one, 63 healthy and 13 hospitalized pilots participated. Each pilot performed a double 180 degrees circuit flight program with and without secondary task (three digit operation). The operator performance, score of secondary task and cost of physiological effort were measured and compared by PRCCES in the two conditions. Then, each pilot's flight skill in training was subjectively scored by instructor pilot ratings. In study two, 7 healthy pilots volunteered to take part in the experiment on the effects of sleep deprivation on pilot's PRC. Each participant had PRC tested pre- and post-8 h sleep deprivation. The results show that the PRC values of a healthy pilot was positively correlated with abilities of flexibility, operating and correcting deviation, attention distribution, and accuracy of instrument flight in the air (r = 0.27-0.40, p < 0.05), and negatively correlated with emotional anxiety in flight (r = -0.40, p < 0.05). The values of PRC in healthy pilots (0.61 +/- 0.17) were significantly higher than that of hospitalized pilots (0.43 +/- 0.15) (p < 0.05). The PRC value after 8 h sleep loss (0.50 +/- 0.17) was significantly lower than those before sleep loss (0.70 +/- 0.15) (p < 0.05). We conclude that a pilot's PRC, which was closely related to flight ability and functional state, could partly represent the pilot's professional reliability. It is worthwhile to further research using a pilot's PRC as a predictor of mental workload in aircraft design.

  3. NHEXAS PHASE I ARIZONA STUDY--STANDARD OPERATING PROCEDURE FOR FIRST STAGE OF CLEANING ELECTRONIC DATA (HAND ENTRY) (UA-D-16.0)

    EPA Science Inventory

    The purpose of this SOP is to provide a standard method for the "first stage" of cleaning data. The first cleaning stage takes place after data verification and before master database appendage. This procedure applies to (1) post-keypunch data collected by the NHEXAS Arizona st...

  4. Arab-American adolescent tobacco use: four pilot studies.

    PubMed

    Rice, Virginia Hill; Templin, Thomas; Kulwicki, Anahid

    2003-11-01

    Four pilot studies were conducted to determine the (1) current tobacco use patterns and predictors among 14- to 18-year-old Arab-American youths; (2) psychometric properties of study measures (English and Arabic); (3) cultural appropriateness of Project Toward No Tobacco (TNT) for intervention; (4) accessible population for a longitudinal study. Three studies were descriptive and one used a pretest-posttest design. From four Pilot Focus groups (N = 28 smokers) key tobacco use themes emerged along with information on study measures and the Project TNT intervention; Pilot Intervention tested the tailored Project TNT intervention with 9 Arab-American teens; Pilot Clinic (N = 44) determined the characteristics of the accessible teen health clinic population; and Pilot School (N = 119) obtained tobacco use data only. From Pilot Focus seven themes (being cool, "nshar ma'a al shabab" [hanging out with the guys], present [time] orientation, smoking feels and tastes good, keeps your mind off trouble, easy to get, and (many) "barriers to quitting") emerged from the data. In the Pilot Intervention a 37.5% cessation rate was found. In the Pilot Clinic study, 24% males and 17% females smoked. The current smoking rate in the Pilot School (N = 119) sample was 17%; 34% admitted to having ever smoked (even a puff). Significant predictors for current tobacco use included poor grades, stress, having many family members and peers who smoke, being exposed to many hours of smoking each day, receiving offers of tobacco products, advertising and mail, and believing that tobacco can help one to make friends. The four pilots contributed unique and essential knowledge for designing a longitudinal clinical trial on tobacco use by Arab-American adolescents.

  5. Assessment of terminal cleaning in pediatric isolation rooms: Options for low-resource settings.

    PubMed

    Dramowski, Angela; Whitelaw, Andrew; Cotton, Mark F

    2016-12-01

    Few studies have evaluated terminal cleaning in low-resource settings. Adequacy of pediatric isolation room terminal cleaning was evaluated using quantitative bacterial surface cultures, ATP bioluminescence assays, and fluorescent high-touch surface markers at Tygerberg Children's Hospital in South Africa (August 1, 2014-October 31, 2015). Cleaning adequacy was assessed by comparing pre- and postcleaning measurements. Influence of verbal feedback was determined by comparing cleaners' first and subsequent cleaning episodes. Cleaning methods were compared for cost, time, and feasibility. Adequacy of terminal cleaning was evaluated in 25 isolation rooms after hospitalization for pulmonary tuberculosis (n = 13), respiratory (n = 5) and enteric viruses (n = 5), pertussis (n = 1), and methicillin-resistant Staphylococcus aureus (n = 1). Mean aerobic colony counts and mean ATP relative light units declined between pre- and postcleaning evaluations (39 ± 41 to 15 ± 30 [P < .001] and 72 ± 40 to 23 ± 11 [P < .001]). Fluorescent marker removal was initially poor, but improved significantly at subsequent cleaning episodes (17 out of 78 [22%] to 121 out of 198 [61%]; P < .001); mean aerobic colony counts and ATP values also declined significantly following feedback. Cost, time, and resources required for ATP and surface cultures far exceeded that required for fluorescent markers. Adequacy of isolation room cleaning improved following feedback to cleaning staff. Fluorescent markers are an inexpensive option for cleaning evaluation and training in low-resource settings. Copyright © 2016 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  6. Dry cleaning of Turkish coal

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cicek, T.

    2008-07-01

    This study dealt with the upgrading of two different type of Turkish coal by a dry cleaning method using a modified air table. The industrial size air table used in this study is a device for removing stones from agricultural products. This study investigates the technical and economical feasibility of the dry cleaning method which has never been applied before on coals in Turkey. The application of a dry cleaning method on Turkish coals designated for power generation without generating environmental pollution and ensuring a stable coal quality are the main objectives of this study. The size fractions of 5-8,more » 3-5, and 1-3 mm of the investigated coals were used in the upgrading experiments. Satisfactory results were achieved with coal from the Soma region, whereas the upgrading results of Hsamlar coal were objectionable for the coarser size fractions. However, acceptable results were obtained for the size fraction 1-3 mm of Hsamlar coal.« less

  7. Effects of wet cleaning with disodium octaborate tetrahydrate on dust mites (Acari: Pyroglyphidae) in carpet.

    PubMed

    Vyszenski-Moher, Diann L; Arlian, Larry G

    2003-07-01

    In a controlled laboratory study, disodium octaborate tetrahydrate (DOT) applied to carpets with a carpet-cleaning machine at a rate of 509 ml DOT/8.15 liter H2O/100 m2 (two cups DOT/2 gal H2O/100 feet2) reduced survival and population growth of live Dermatophagoides farinae and Dermatophagoides pteronyssinus by > or = 98% compared with water-cleaned and uncleaned carpets at 8 wk postcleaning. Cleaning with DOT was more effective against D. pteronyssinus than D. farinae.

  8. Water ingestion during swimming activities in a pool: a pilot study.

    PubMed

    Dufour, Alfred P; Evans, Otis; Behymer, Thomas D; Cantú, Ricardo

    2006-12-01

    Chloroisocyanurates are commonly added to outdoor swimming pools to stabilize chlorine disinfectants. The chloroisocyanurates decompose slowly to release chlorine and cyanuric acid. Studies conducted to determine if the chloroisocyanurates might be toxic to swimmers showed that they were not and that ingested cyanuric acid passed through the body unmetabolized. This fact was used to determine the amount of water swallowed during swimming activity. Fifty-three recreational swimmers, using a community swimming pool disinfected with cyanuric acid stabilized chlorine, participated in the study. The participants did not swim on the day before or after the test swim. The swimmers were asked to actively swim for at least 45 minutes and to collect their urine for the next 24 hours. Cyanuric acid was measured in pool water using high performance liquid chromatography and porous graphitic carbon columns with UV detection. The urine sample assay required a clean-up procedure to remove urinary proteins and interfering substances. Results of the study indicate that non-adults ingest about twice as much water as adults during swimming activity. The average amount of water swallowed by non-adults and adults was 37 ml and 16 ml, respectively. The design for this study and the analytical methodology used to assay cyanuric acid in swimming pool water and human urine were effective for measuring the volume of water swallowed during swimming activity.

  9. Improving Overall Equipment Effectiveness Using CPM and MOST: A Case Study of an Indonesian Pharmaceutical Company

    NASA Astrophysics Data System (ADS)

    Omega, Dousmaris; Andika, Aditya

    2017-12-01

    This paper discusses the results of a research conducted on the production process of an Indonesian pharmaceutical company. The company is experiencing low performance in the Overall Equipment Effectiveness (OEE) metric. The OEE of the company machines are below world class standard. The machine that has the lowest OEE is the filler machine. Through observation and analysis, it is found that the cleaning process of the filler machine consumes significant amount of time. The long duration of the cleaning process happens because there is no structured division of jobs between cleaning operators, differences in operators’ ability, and operators’ inability in utilizing available cleaning equipment. The company needs to improve the cleaning process. Therefore, Critical Path Method (CPM) analysis is conducted to find out what activities are critical in order to shorten and simplify the cleaning process in the division of tasks. Afterwards, The Maynard Operation and Sequence Technique (MOST) method is used to reduce ineffective movement and specify the cleaning process standard time. From CPM and MOST, it is obtained the shortest time of the cleaning process is 1 hour 28 minutes and the standard time is 1 hour 38.826 minutes.

  10. Conservation of artists' acrylic emulsion paints: XPS, NEXAFS and ATR-FTIR studies of wet cleaning methods

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Willneff, E. A.; Ormsby, B. A.; Stevens, J. S.

    Works of art prepared with acrylic emulsion paints became commercially available in the 1960s. It is increasingly necessary to undertake and optimise cleaning and preventative conservation treatments to ensure their longevity. Model artists' acrylic paint films covered with artificial soiling were thus prepared on a canvas support and exposed to a variety of wet cleaning treatments based on aqueous or hydrocarbon solvent systems. This included some with additives such as chelating agents and/or surfactants, and microemulsion systems made specifically for conservation practice. The impact of cleaning (soiling removal) on the paint film surface was examined visually and correlated with resultsmore » of attenuated total reflection Fourier transform infrared, XPS and near-edge X-ray absorption fine structure analyses – three spectroscopic techniques with increasing surface sensitivity ranging from approximately $-$ 1000, 10 and 5 nm, respectively. Visual analysis established the relative cleaning efficacy of the wet cleaning treatments in line with previous results. X-ray spectroscopy analysis provided significant additional findings, including evidence for (i) surfactant extraction following aqueous swabbing, (ii) modifications to pigment following cleaning and (iii) cleaning system residues.« less

  11. Conservation of artists' acrylic emulsion paints: XPS, NEXAFS and ATR-FTIR studies of wet cleaning methods

    DOE PAGES

    Willneff, E. A.; Ormsby, B. A.; Stevens, J. S.; ...

    2014-02-17

    Works of art prepared with acrylic emulsion paints became commercially available in the 1960s. It is increasingly necessary to undertake and optimise cleaning and preventative conservation treatments to ensure their longevity. Model artists' acrylic paint films covered with artificial soiling were thus prepared on a canvas support and exposed to a variety of wet cleaning treatments based on aqueous or hydrocarbon solvent systems. This included some with additives such as chelating agents and/or surfactants, and microemulsion systems made specifically for conservation practice. The impact of cleaning (soiling removal) on the paint film surface was examined visually and correlated with resultsmore » of attenuated total reflection Fourier transform infrared, XPS and near-edge X-ray absorption fine structure analyses – three spectroscopic techniques with increasing surface sensitivity ranging from approximately $-$ 1000, 10 and 5 nm, respectively. Visual analysis established the relative cleaning efficacy of the wet cleaning treatments in line with previous results. X-ray spectroscopy analysis provided significant additional findings, including evidence for (i) surfactant extraction following aqueous swabbing, (ii) modifications to pigment following cleaning and (iii) cleaning system residues.« less

  12. Study of discharge cleaning process in JIPP T-2 Torus by residual gas analyzer

    NASA Astrophysics Data System (ADS)

    Noda, N.; Hirokura, S.; Taniguchi, Y.; Tanahashi, S.

    1982-12-01

    During discharge cleaning, decay time of water vapor pressure changes when the pressure reaches a certain level. A long decay time observed in the later phase can be interpreted as a result of a slow deoxidization rate of chromium oxide, which may dominate the cleaning process in this phase. Optimization of plasma density for the cleaning is discussed comparing the experimental results on density dependence of water vapor pressure with a result based on a zero dimensional calculation for particle balance. One of the essential points for effective cleaning is the raising of the electron density of the plasma high enough that the dissociation loss rate of H2O is as large as the sticking loss rate. A density as high as 10 to the 11th power/cu cm is required for a clean surface condition where sticking probability is presumed to be around 0.5.

  13. Temperature control of thermal-gas-dynamical installation in cleaning oil-well tubes

    NASA Astrophysics Data System (ADS)

    Penner, V. A.; Martemyanov, D. B.; Pshenichnikova, V. V.

    2017-08-01

    The article provides the study results of cleaning oil-well tubes, the oil-well tube failure reasons for service by their types have been considered. The chemical method of cleaning oil-well tubes as the least expensive has been reviewed when acid solution moves to the interptube space mixing up with oil and liquidates paraffin and pitches deposits on the internal pipe surface. Except the chemical method of pipes cleaning the mechanical one was considered as well. Also the disadvantages -such as the low productivity of cleaning and design complexity- of this deposits removal method on the internal oil-well tube surface have been considered. An effective method for cleaning oil-well tubing from paraffin and pitches by the thermodynamic plant based on the aircraft engine has been introduced for the first time. The temperature distribution graph in the gas stream at the engine output has been given.

  14. 78 FR 23941 - Pilot Program for Early Feasibility Study Investigational Device Exemption Applications...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-04-23

    ...] Pilot Program for Early Feasibility Study Investigational Device Exemption Applications; Extending the... 13343), FDA terminated the acceptance of applications into the program and extended the pilot program for the nine accepted sponsors until May 8, 2013. The pilot program will be further extended for the...

  15. Wash or wipe? A comparative study of skin physiological changes between water washing and wiping after skin cleaning.

    PubMed

    Ogai, K; Matsumoto, M; Aoki, M; Ota, R; Hashimoto, K; Wada, R; Kobayashi, M; Sugama, J

    2017-11-01

    Presently, skin-cleaning agents that claim to be removed by water or wiping alone are commercially available and have been used for the purpose of bed baths. However, there is a lack of knowledge on how water washing and wiping differently affect skin physiological functions or ceramide content. The aim of this study was to compare the effects of water washing and wiping on skin physiological functions and ceramide content. Three kinds of the cleaning agents with different removal techniques (ie, water washing and wiping) were used in this study. Skin physiological functions (ie, transepidermal water loss, skin hydration, and skin pH) and skin ceramide content were measured before and after seven consecutive days of the application of each cleaning agent. No significant differences in skin physiological functions or ceramide content were observed between water washing and wiping. Cleaning agents that claim to be removed by water washing or wiping do not affect skin physiological functions or ceramide content by either removal method. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  16. Frequency and longitudinal trends of household care product use

    NASA Astrophysics Data System (ADS)

    Moran, Rebecca E.; Bennett, Deborah H.; Tancredi, Daniel J.; Wu, Xiangmei (May); Ritz, Beate; Hertz-Picciotto, Irva

    2012-08-01

    The use of household cleaning products and air fresheners exposes people to a variety of chemicals, including some that have been shown to be irritants, potential carcinogens and endocrine disrupting compounds. In addition, some react with ambient ozone infiltrating to the indoor environment to form potentially toxic secondary pollutants. Although realistic estimates of usage patterns are necessary for modeling potential exposures in risk assessments, few studies have documented cleaning habits and product usage to characterize how they vary between households and over time. In addition, understanding within-household temporal variability of use is important to assess the reliability of exposure questionnaires used in epidemiological surveys and improve the cost-efficiency of data collection. In the SUPERB (Study of Use of Products and Exposure-Related Behavior) study, frequencies of use of eight types of household cleaning products and air fresheners and the performance of different types of cleaning tasks are collected in three annual telephone and six quarterly web-based surveys. All-purpose and glass cleaners were the products most frequently used among all products surveyed. Use frequencies differed by demographic and other household characteristics for some products. Product usage was internally consistent, with over 75% of pairwise cross-sectional correlations between product types statistically significantly different from zero. In addition, each product type was correlated with at least one cleaning habit. Frequency of cleaning product use and performing cleaning tasks did not vary by season. An examination of intra-household variability showed moderately to highly consistent usage patterns over time, with lower temporal consistency observed among products used more frequently, such as all-purpose cleaners. Frequency of household care product usage was consistent enough that in epidemiologic studies, participants can be classified, for example, into three categories on the basis of a single assessment, with only minimal misclassification.

  17. Experimental investigation on cleaning of corroded ancient coins using a Nd:YAG laser

    NASA Astrophysics Data System (ADS)

    Zhu, Huazhong; Lu, Jian; Ni, Xiaowu; Shen, Zhonghua

    2017-05-01

    The objective of the work reported is to study experimentally on the removal of corrosion layer from the ancient coins using laser beam as the conservation tool. With the use of Q-switched Nd:YAG laser radiation at 1064 nm, dry laser cleaning, steam laser cleaning and chemical-assisted laser cleaning were used to find out a more suitable and efficient laser treatment for corrosion removal. Cleaning tests were performed on ancient Chinese coins. Experimental results shows that the dry laser cleaning was not successful at removing all types of corrosion crust. It was possible to remove the outer thicker layer of the corrosion products (typically known as patina), but failed on the thinner layer of cuprite. The steam laser cleaning could decrease the initial removal threshold and improve the removal efficiency especially for the oxidation with powdery structure. As for chemical-assisted laser treatment, the cleaning results demonstrate that the combination of laser and chemical reagent could provide a considerable improvement in corrosion removal compared with the conventional laser treatments. Most of the corrosion contaminant was stripped, even the cuprite layer. Moreover, no secondary pollution was formed on the cleaned surface. X-ray fluorescence was applied to determine the variation of composition of surface layer and bulk metal before and after the coins cleaned. It shows that all of the three laser treatments were efficient to reduce the chlorine concentration on the surface of the coins more than 75%.

  18. Wheelchair cleaning and disinfection in Canadian health care facilities: "That's wheelie gross!".

    PubMed

    Gardner, Paula; Muller, Matthew P; Prior, Betty; So, Ken; Tooze, Jane; Eum, Linda; Kachur, Oksana

    2014-11-01

    Wheelchairs are complex equipment that come in close contact with individuals at increased risk of transmitting and acquiring antibiotic-resistant organisms and health care-associated infection. The purpose of this study was to determine the status of wheelchair cleaning and disinfection in Canadian health care facilities. Acute care hospitals (ACHs), chronic care hospitals (CCHs), and long-term care facilities (LTCFs) were contacted and the individual responsible for oversight of wheelchair cleaning and disinfection was identified. A structured interview was conducted that focused on current practices and concerns, barriers to effective wheelchair cleaning and disinfection, and potential solutions. Interviews were completed at 48 of the 54 facilities contacted (89%), including 18 ACHs, 16 CCHs, and 14 LTCFs. Most (n = 24) facilities had 50-200 in-house wheelchairs. Respondents were very concerned about wheelchair cleaning as an infection control issue. Specific concerns included the lack of reliable systems for tracking and identifying dirty and clean wheelchairs (71%, 34/48), failure to clean and disinfect wheelchairs between patients (52%, 25/48), difficulty cleaning cushions (42%, 20/48), lack of guidelines (35%, 27/48), continued use of visibly soiled wheelchairs (29%, 14/48) and lack of resources (25%, 12/48). Our results suggest that wheelchair cleaning and disinfection is not optimally performed at many Canadian hospitals and LTCFs. Specific guidance on wheelchair cleaning and disinfection is necessary. Copyright © 2014 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  19. Does ear endoscopy provide advantages in the outpatient management of open mastoidectomy cavities?

    PubMed

    Freire, Gustavo Subtil Magalhães; Sampaio, Andre Luiz Lopes; Lopes, Rafaela Aquino Fernandes; Nakanishi, Márcio; de Oliveira, Carlos Augusto Costa Pires

    2018-01-01

    To evaluate the use of ear endoscopy in the postoperative management of open mastoidectomy cavities, and to test whether ear endoscopy improves inspection and cleaning compared with ear microscopy. Prospective study. Thirty-two ears were divided into two groups: group 1, examination and cleaning of mastoid cavities under endoscopic visualization after microscopic standard ear cleaning; group 2, examination and cleaning of mastoid cavities under microscopic visualization after endoscope-assisted ear cleaning. We assessed the ability of each method to provide exposure and facilitate cleaning, comparing the benefits of microscopy and endoscopy when used sequentially and vice-versa. Endoscopy provided additional benefits for exposure in 61.1% of cases and cleaning in 66.7%. Microscopy provided no additional benefits in terms of exposure in any case, and provided added benefit for cleaning in only 21.4% of cases. For outpatient postoperative care of open mastoidectomy cavities, ear endoscopy provides greater benefit over ear microscopy than vice-versa. In over half of all cases, endoscopy was able to expose areas not visualized under the microscope. Furthermore, in two-thirds of cases, endoscopy enabled removal of material that could not be cleared under microscopy. Ear endoscopy was superior to microscopy in terms of enabling exposure and cleaning of hard-to-reach sites, due to its wider field of vision. Ear endoscopy is a feasible technique for the postoperative management of open mastoidectomy cavities. Ear endoscopy provided superior advantages in terms of exposure and aural cleaning compared with microscopy.

  20. Defining Feasibility and Pilot Studies in Preparation for Randomised Controlled Trials: Development of a Conceptual Framework.

    PubMed

    Eldridge, Sandra M; Lancaster, Gillian A; Campbell, Michael J; Thabane, Lehana; Hopewell, Sally; Coleman, Claire L; Bond, Christine M

    2016-01-01

    We describe a framework for defining pilot and feasibility studies focusing on studies conducted in preparation for a randomised controlled trial. To develop the framework, we undertook a Delphi survey; ran an open meeting at a trial methodology conference; conducted a review of definitions outside the health research context; consulted experts at an international consensus meeting; and reviewed 27 empirical pilot or feasibility studies. We initially adopted mutually exclusive definitions of pilot and feasibility studies. However, some Delphi survey respondents and the majority of open meeting attendees disagreed with the idea of mutually exclusive definitions. Their viewpoint was supported by definitions outside the health research context, the use of the terms 'pilot' and 'feasibility' in the literature, and participants at the international consensus meeting. In our framework, pilot studies are a subset of feasibility studies, rather than the two being mutually exclusive. A feasibility study asks whether something can be done, should we proceed with it, and if so, how. A pilot study asks the same questions but also has a specific design feature: in a pilot study a future study, or part of a future study, is conducted on a smaller scale. We suggest that to facilitate their identification, these studies should be clearly identified using the terms 'feasibility' or 'pilot' as appropriate. This should include feasibility studies that are largely qualitative; we found these difficult to identify in electronic searches because researchers rarely used the term 'feasibility' in the title or abstract of such studies. Investigators should also report appropriate objectives and methods related to feasibility; and give clear confirmation that their study is in preparation for a future randomised controlled trial designed to assess the effect of an intervention.

  1. Factors influencing stethoscope cleanliness among clinical medical students.

    PubMed

    Saunders, C; Hryhorskyj, L; Skinner, J

    2013-07-01

    This study aims to identify current stethoscope hygiene habits and attitudes in a UK medical school setting. Students completed a questionnaire using Likert-scale questions and free-text answers. A total of 308 questionnaires were completed from a potential 750 students (41%); 22.4% of respondents had never cleaned their stethoscope and only 3.9% cleaned their stethoscope after every patient. Significant correlations were identified between cleaning frequency and: others acting as role models (P = 0.001), students having confidence in how to clean stethoscopes (P = 0.001), and students thinking cleaning was important (P = 0.01), thereby highlighting inadequate education and role models as potential problems. Copyright © 2013 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  2. Study and development of 22 kW peak power fiber coupled short pulse Nd:YAG laser for cleaning applications

    NASA Astrophysics Data System (ADS)

    Choubey, Ambar; Vishwakarma, S. C.; Vachhani, D. M.; Singh, Ravindra; Misra, Pushkar; Jain, R. K.; Arya, R.; Upadhyaya, B. N.; Oak, S. M.

    2014-11-01

    Free running short pulse Nd:YAG laser of microsecond pulse duration and high peak power has a unique capability to ablate material from the surface without heat propagation into the bulk. Applications of short pulse Nd:YAG lasers include cleaning and restoration of marble, stones, and a variety of metals for conservation. A study on the development of high peak power short pulses from Nd:YAG laser along with its cleaning and conservation applications has been performed. A pulse energy of 1.25 J with 55 μs pulse duration and a maximum peak power of 22 kW has been achieved. Laser beam has an M2 value of ~28 and a pulse-to-pulse stability of ±2.5%. A lower value of M2 means a better beam quality of the laser in multimode operation. A top hat spatial profile of the laser beam was achieved at the exit end of 200 μm core diameter optical fiber, which is desirable for uniform cleaning. This laser system has been evaluated for efficient cleaning of surface contaminations on marble, zircaloy, and inconel materials for conservation with cleaning efficiency as high as 98%. Laser's cleaning quality and efficiency have been analysed by using a microscope, a scanning electron microscope (SEM), and X-ray photon spectroscopy (XPS) measurements.

  3. The present situation of the irradiation application industry and irradiation facilities in Japan

    NASA Astrophysics Data System (ADS)

    Mizusawa, K.; Baba, T.

    2003-08-01

    The irradiation application industry and irradiation facilities in Japan have been making slow but steady progress for the past 2-3 years. Beside conventional applications, new ones such as carbon fibers and membrane filters have come into the market. There are a lot of new applications about to emerge. PE tubing, already is in the European market, is being evaluated by end users in Japan. Cleaning of dioxin in exhaust gas was successfully tested at a pilot plant. Cross-linked PTFE and polyamide are waiting customers' evaluations as an engineering plastic. Surface cross-linking of artificial polycarbonate teeth has yielded remarkable experimental results. Cross-linking of polycaprolactone will be useful for biodegradable products. Being aware of the future growth of irradiation industry, contract service providers opened new facilities or increased their capability. Beside in-house facilities, there are now three Co-60 facilities and nine EB facilities available for contract irradiation in Japan.

  4. Nanoparticles with photoinduced precipitation for the extraction of pollutants from water and soil

    PubMed Central

    Brandl, Ferdinand; Bertrand, Nicolas; Lima, Eliana Martins; Langer, Robert

    2015-01-01

    Nanotechnology may offer fast and effective solutions for environmental clean-up. Herein, amphiphilic diblock copolymers are used to develop a platform of photosensitive core-shell nanoparticles. Irradiation with ultraviolet light removes the protective layer responsible for colloidal stability; as a result, the nanoparticles are rapidly and irreversibly converted to macroscopic aggregates. The associated phase separation allows measuring the partitioning of small molecules between the aqueous phase and nanoparticles; data suggests that interactions are enhanced by decreasing the particle size. Adsorption onto nanoparticles can be exploited to efficiently remove hydrophobic pollutants from water and contaminated soil. Preliminary in vivo experiments suggest that treatment with photocleavable nanoparticles can significantly reduce the teratogenicity of bisphenol A, triclosan and 17α-ethinyl estradiol without generating obviously toxic byproducts. Small-scale pilot experiments on wastewater, thermal printing paper and contaminated soil demonstrate the applicability of the approach. PMID:26196119

  5. Membrane filtration of olive mill wastewater and exploitation of its fractions.

    PubMed

    Paraskeva, C A; Papadakis, V G; Kanellopoulou, D G; Koutsoukos, P G; Angelopoulos, K C

    2007-04-01

    Olive mill wastewater (OMW) produced from small units scattered in rural areas of Southern Europe is a major source of pollution of surface and subsurface water. In the present work, a treatment scheme based on physical separation methods is presented. The investigation was carried out using a pilot-plant unit equipped with ultrafiltration, nanofiltration, and reverse osmosis membranes. Approximately 80% of the total volume of wastewater treated by the membrane units was sufficiently cleaned to meet the standards for irrigation water. The concentrated fractions collected in the treatment concentrates were characterized by high organic load and high content of phenolic compounds. The concentrates were tested in hydroponic systems to examine their toxicity towards undesired herbs. The calculations of the cost of the overall process showed that fixed and operational costs could be recovered from the exploitation of OMW byproducts as water for irrigation and/or as bioherbicides.

  6. Catalytic conversion wood syngas to synthetic aviation turbine fuels over a multifunctional catalyst.

    PubMed

    Yan, Qiangu; Yu, Fei; Liu, Jian; Street, Jason; Gao, Jinsen; Cai, Zhiyong; Zhang, Jilei

    2013-01-01

    A continuous process involving gasification, syngas cleaning, and Fischer-Tropsch (FT) synthesis was developed to efficiently produce synthetic aviation turbine fuels (SATFs). Oak-tree wood chips were first gasified to syngas over a commercial pilot plant downdraft gasifier. The raw wood syngas contains about 47% N(2), 21% CO, 18% H(2), 12% CO(2,) 2% CH(4) and trace amounts of impurities. A purification reaction system was designed to remove the impurities in the syngas such as moisture, oxygen, sulfur, ammonia, and tar. The purified syngas meets the requirements for catalytic conversion to liquid fuels. A multi-functional catalyst was developed and tested for the catalytic conversion of wood syngas to SATFs. It was demonstrated that liquid fuels similar to commercial aviation turbine fuels (Jet A) was successfully synthesized from bio-syngas. Copyright © 2012 Elsevier Ltd. All rights reserved.

  7. Nanoparticles with photoinduced precipitation for the extraction of pollutants from water and soil

    NASA Astrophysics Data System (ADS)

    Brandl, Ferdinand; Bertrand, Nicolas; Lima, Eliana Martins; Langer, Robert

    2015-07-01

    Nanotechnology may offer fast and effective solutions for environmental clean-up. Herein, amphiphilic diblock copolymers are used to develop a platform of photosensitive core-shell nanoparticles. Irradiation with ultraviolet light removes the protective layer responsible for colloidal stability; as a result, the nanoparticles are rapidly and irreversibly converted to macroscopic aggregates. The associated phase separation allows measuring the partitioning of small molecules between the aqueous phase and nanoparticles; data suggests that interactions are enhanced by decreasing the particle size. Adsorption onto nanoparticles can be exploited to efficiently remove hydrophobic pollutants from water and contaminated soil. Preliminary in vivo experiments suggest that treatment with photocleavable nanoparticles can significantly reduce the teratogenicity of bisphenol A, triclosan and 17α-ethinyl estradiol without generating obviously toxic byproducts. Small-scale pilot experiments on wastewater, thermal printing paper and contaminated soil demonstrate the applicability of the approach.

  8. Test Vehicle Forebody Wake Effects on CPAS Parachutes

    NASA Technical Reports Server (NTRS)

    Ray, Eric S.

    2017-01-01

    Parachute drag performance has been reconstructed for a large number of Capsule Parachute Assembly System (CPAS) flight tests. This allows for determining forebody wake effects indirectly through statistical means. When data are available in a "clean" wake, such as behind a slender test vehicle, the relative degradation in performance for other test vehicles can be computed as a Pressure Recovery Fraction (PRF). All four CPAS parachute types were evaluated: Forward Bay Cover Parachutes (FBCPs), Drogues, Pilots, and Mains. Many tests used the missile-shaped Parachute Compartment Drop Test Vehicle (PCDTV) to obtain data at high airspeeds. Other tests used the Orion "boilerplate" Parachute Test Vehicle (PTV) to evaluate parachute performance in a representative heatshield wake. Drag data from both vehicles are normalized to a "capsule" forebody equivalent for Orion simulations. A separate database of PCDTV-specific performance is maintained to accurately predict flight tests. Data are shared among analogous parachutes whenever possible to maximize statistical significance.

  9. STS-47 crew & backups pose for portrait in SLJ module at KSC during training

    NASA Image and Video Library

    1992-07-25

    S92-44303 --- STS-47 Endeavour, Orbiter Vehicle (OV) 105, crew members and back-up payload specialists, wearing clean suits, pose for a group portrait in the Spacelab Japan (SLJ) module. The team is at the Kennedy Space Center's (KSC's) Orbiter Processing Facility (OPF) to inspect SLJ configuration and OV-105 preparations. Kneeling, from left, are back-up Payload Specialist Chiaki Naito-Mukai; Mission Specialist N. Jan Davis; and backup Payload Specialist Takao Doi. Standing, from the left, are Pilot Curtis L. Brown,Jr; Payload Commander Mark C. Lee; Jerome Apt; Payload Specialist Mamoru Mohri; Commander Robert L. Gibson; Mae C. Jemison; and back-up Payload Specialist Stanely L. Koszelak. Mohri, Mukai, and Doi represent the National Space Development Agency of Japan (NASDA). View provided by KSC with alternate KSC number KSC-92PC-1647. Photo credit: NASA

  10. Experimental clean combustor program: Diesel no. 2 fuel addendum, phase 3

    NASA Technical Reports Server (NTRS)

    Gleason, C. C.; Bahr, D. W.

    1979-01-01

    A CF6-50 engine equipped with an advanced, low emission, double annular combustor was operated 4.8 hours with No. 2 diesel fuel. Fourteen steady-state operating conditions ranging from idle to full power were investigated. Engine/combustor performance and exhaust emissions were obtained and compared to JF-5 fueled test results. With one exception, fuel effects were very small and in agreement with previously obtained combustor test rig results. At high power operating condition, the two fuels produced virtually the same peak metal temperatures and exhaust emission levels. At low power operating conditions, where only the pilot stage was fueled, smoke levels tended to be significantly higher with No. 2 diesel fuel. Additional development of this combustor concept is needed in the areas of exit temperature distribution, engine fuel control, and exhaust emission levels before it can be considered for production engine use.

  11. KSC-08pd3744

    NASA Image and Video Library

    2008-11-19

    CAPE CANAVERAL, Fla. – At the Parachute Refurbishment Facility at NASA's Kennedy Space Center in Florida, workers place rods under the lines of the parachutes recovered from sea after the launch of space shuttle Endeavour on the STS-126 mission to hang them on a monorail system. Behind them, the parachutes are suspended from the monorail. The parachutes are used to slow the descent of the solid rocket boosters that are jettisoned during liftoff. The monorail will transport each parachute into a 30,000-gallon washer and a huge dryer heated with 140-degree air at 13,000 cubic feet per minute. One pilot, one drogue and three main canopies per booster slow the booster’s fall from about 360 mph to 50 mph. After the chutes are cleaned and repaired, they must be carefully packed into their bags so they will deploy correctly the next time they are used. Photo credit: NASA/Jim Grossmann

  12. KSC-08pd3739

    NASA Image and Video Library

    2008-11-19

    CAPE CANAVERAL, Fla. – Parachutes recovered from sea after the launch of space shuttle Endeavour on the STS-126 mission are stretched out at the Parachute Refurbishment Facility at NASA's Kennedy Space Center in Florida to detangle them. The parachutes are used to slow the descent of the solid rocket boosters that are jettisoned during liftoff. After the chutes are returned to the facility following launch, a hanging monorail system is used to transport each parachute into a 30,000-gallon washer and then into a huge dryer heated with 140-de¬gree air at 13,000 cubic feet per minute. One pilot, one drogue and three main canopies per booster slow the booster’s fall from about 360 mph to 50 mph. After the chutes are cleaned and repaired, they must be care¬fully packed into their bags so they will deploy correctly the next time they are used. Photo credit: NASA/Jim Grossmann

  13. 75 FR 48327 - Science Advisory Board Staff Office; Notification of a Public Meeting of the Advisory Council on...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-08-10

    ... Analysis of the benefits and costs of the Clean Air Act. DATES: The meeting will be held on Thursday... Second Section 812 Prospective Benefit-Cost Analysis of the Clean Air Act. The Council was established in... Clean Air Act Amendments (CAAA), EPA conducts periodic studies to assess benefits and costs of the EPA's...

  14. 75 FR 4070 - Science Advisory Board Staff Office; Notification of a Public Meeting of the Air Quality Modeling...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-01-26

    ... Prospective Analysis of the benefits and costs of the Clean Air Act. DATES: The meeting date is Friday... support the Second Prospective Section 812 Benefit-Cost Analysis of the Clean Air Act. The Council was... studies to assess benefits and costs of the EPA's regulatory actions under the Clean Air Act. The Council...

  15. Study to determine the IFR operational profile and problems of the general aviation single pilot

    NASA Technical Reports Server (NTRS)

    Weislogel, G. S.

    1983-01-01

    General aviation single pilot operating under instrument flight rules (GA SPIFR) was studied. The objectives of the study were to (1) develop a GA SPIFR operational profile, (2) identify problems experienced by the GA SPIFR pilot, and (3) identify research tasks which have the potential for eliminating or reducing the severity of the problems. To obtain the information necessary to accomplish these objectives, a mail questionnaire survey of instrument rated pilots was conducted. The general aviation IFR single pilot operational profile and selected data analysis examples are presented.

  16. Piloted studies of Enhanced or Synthetic Vision display parameters

    NASA Technical Reports Server (NTRS)

    Harris, Randall L., Sr.; Parrish, Russell V.

    1992-01-01

    This paper summarizes the results of several studies conducted at Langley Research Center over the past few years. The purposes of these studies were to investigate parameters of pictorial displays and imaging sensors that affect pilot approach and landing performance. Pictorial displays have demonstrated exceptional tracking performance and improved the pilots' spatial awareness. Stereopsis cueing improved pilot flight performance and reduced pilot stress. Sensor image parameters such as increased field-of-view. faster image update rate, and aiding symbology improved flare initiation. Finer image resolution and magnification improved attitude control performance parameters.

  17. Testing the cleaning effectiveness of new ecological aqueous dispersions applied on old icons

    NASA Astrophysics Data System (ADS)

    Vasilache, Viorica; Sandu, Irina Crina Anca; Pruteanu, Silvea; Caldeira, Ana Teresa; Simionescu, Atena Elena; Sandu, Ion

    2016-03-01

    Adherent deposits are very aggressive towards ancient heritage paintings since they affect the varnish and the painting's layers, sometimes reaching the preparative layers. The biggest problem to the restorer is their removal without affecting the patina, the transparent varnish (well preserved) and fine colour glazes made during painting. Therefore, their removal requires preliminary cleaning tests that allow the optimization of the cleaning system composition that is going to be used. The study was focused on organic natural systems, as colourless supernatants, some of them used during ages, but insufficiently studied. The paper presents an evaluation of the effectiveness of cleaning varnished icons of the nineteenth century, with complex conservation cases using supernatants derived from aqueous dispersions extracted from vegetables and dry indigenous herbal infusions. Best results, after six consecutive cleaning steps, on tempera old icon was obtained for a mixture made of mature white onion juice + extract of Soapwort flowers + corn silk tea + acacia tea. As a best result after just one cleaning step was obtained for a quaternary mixture composed from mature white onion juice + mature carrot juice + corn silk tea + aqueous extract of Soapwort flowers.

  18. Assessment of disinfection of hospital surfaces using different monitoring methods1

    PubMed Central

    Ferreira, Adriano Menis; de Andrade, Denise; Rigotti, Marcelo Alessandro; de Almeida, Margarete Teresa Gottardo; Guerra, Odanir Garcia; dos Santos, Aires Garcia

    2015-01-01

    OBJECTIVE: to assess the efficiency of cleaning/disinfection of surfaces of an Intensive Care Unit. METHOD: descriptive-exploratory study with quantitative approach conducted over the course of four weeks. Visual inspection, bioluminescence adenosine triphosphate and microbiological indicators were used to indicate cleanliness/disinfection. Five surfaces (bed rails, bedside tables, infusion pumps, nurses' counter, and medical prescription table) were assessed before and after the use of rubbing alcohol at 70% (w/v), totaling 160 samples for each method. Non-parametric tests were used considering statistically significant differences at p<0.05. RESULTS: after the cleaning/disinfection process, 87.5, 79.4 and 87.5% of the surfaces were considered clean using the visual inspection, bioluminescence adenosine triphosphate and microbiological analyses, respectively. A statistically significant decrease was observed in the disapproval rates after the cleaning process considering the three assessment methods; the visual inspection was the least reliable. CONCLUSION: the cleaning/disinfection method was efficient in reducing microbial load and organic matter of surfaces, however, these findings require further study to clarify aspects related to the efficiency of friction, its frequency, and whether or not there is association with other inputs to achieve improved results of the cleaning/disinfection process. PMID:26312634

  19. Assessment of disinfection of hospital surfaces using different monitoring methods.

    PubMed

    Ferreira, Adriano Menis; de Andrade, Denise; Rigotti, Marcelo Alessandro; de Almeida, Margarete Teresa Gottardo; Guerra, Odanir Garcia; dos Santos Junior, Aires Garcia

    2015-01-01

    to assess the efficiency of cleaning/disinfection of surfaces of an Intensive Care Unit. descriptive-exploratory study with quantitative approach conducted over the course of four weeks. Visual inspection, bioluminescence adenosine triphosphate and microbiological indicators were used to indicate cleanliness/disinfection. Five surfaces (bed rails, bedside tables, infusion pumps, nurses' counter, and medical prescription table) were assessed before and after the use of rubbing alcohol at 70% (w/v), totaling 160 samples for each method. Non-parametric tests were used considering statistically significant differences at p<0.05. after the cleaning/disinfection process, 87.5, 79.4 and 87.5% of the surfaces were considered clean using the visual inspection, bioluminescence adenosine triphosphate and microbiological analyses, respectively. A statistically significant decrease was observed in the disapproval rates after the cleaning process considering the three assessment methods; the visual inspection was the least reliable. the cleaning/disinfection method was efficient in reducing microbial load and organic matter of surfaces, however, these findings require further study to clarify aspects related to the efficiency of friction, its frequency, and whether or not there is association with other inputs to achieve improved results of the cleaning/disinfection process.

  20. Efficacy of computer-based endoscope cleaning and disinfection using a hospital management information system.

    PubMed

    Wang, Caixia; Chen, Yuanyuan; Yang, Feng; Ren, Jie; Yu, Xin; Wang, Jiani; Sun, Siyu

    2016-08-01

    The present study aimed to assess the efficacy of computer-based endoscope cleaning and disinfection using a hospital management information system (HMIS). A total of 2,674 gastroscopes were eligible for inclusion in this study. For the processes of disinfection management, the gastroscopes were randomly divided into 2 groups: gastroscope disinfection HMIS (GD-HMIS) group and manual group. In the GD-HMIS group, an integrated circuit card (IC card) chip was installed to monitor and record endoscope cleaning and disinfection automatically and in real time, whereas the endoscope cleaning and disinfection in the manual group was recorded manually. The overall disinfection progresses for both groups were recorded, and the total operational time was calculated. For the GD-HMIS group, endoscope disinfection HMIS software was successfully developed. The time to complete a single session of cleaning and disinfecting on a gastroscope was 15.6 minutes (range, 14.3-17.2 minutes) for the GD-HMIS group and 21.3 minutes (range, 20.2-23.9 minutes) for the manual group. Failure to record information, such as the identification number of the endoscope, occasionally occurred in the manual group, which affected the accuracy and reliability of manual recording. Computer-based gastroscope cleaning and disinfection using a hospital management information system could monitor the process of gastroscope cleaning and disinfection in real time and improve the accuracy and reliability, thereby ensuring the quality of gastroscope cleaning and disinfection. Copyright © 2016 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  1. Tooth cleaning frequency in relation to socio-demographic variables and personal hygiene measures among school children of Udaipur district, India.

    PubMed

    Kumar, S; Panwar, J; Vyas, A; Sharma, J; Goutham, B; Duraiswamy, P; Kulkarni, S

    2011-02-01

    The aim of the study was to determine if frequency of tooth cleaning varies with social group, family size, bedtime and other personal hygiene habits among school children. Target population comprised schoolchildren aged 8-16 years of Udaipur district attending public schools. A two stage cluster random sampling procedure was executed to collect the representative sample, consequently final sample size accounted to 852 children. Data were collected by means of structured questionnaires which consisted of questions related to oral hygiene habits including a few general hygiene habits, bed time, family size, family income and dental visiting habits. The results show that 30.5% of the total sample cleaned their teeth twice or more daily and there was no significant difference between the genders for tooth cleaning frequency. Logistic regression analysis revealed that older children and those having less than two siblings were more likely to clean their teeth twice a day than the younger ones and children with more than two siblings. Furthermore, frequency of tooth cleaning was significantly lower among children of parents with low level of education and less annual income as compared with those of high education and more annual income. In addition, tooth cleaning habits were more regular in children using tooth paste and regularly visiting to the dentist. This study observed that tooth cleaning is not an isolated behaviour, but is a part of multifarious pattern of various social and behavioural factors. © 2009 The Authors. Journal compilation © 2009 Blackwell Munksgaard.

  2. Contextual and sociopsychological factors in predicting habitual cleaning of water storage containers in rural Benin

    NASA Astrophysics Data System (ADS)

    Stocker, Andrea; Mosler, Hans-Joachim

    2015-04-01

    Recontamination of drinking water occurring between water collection at the source and the point of consumption is a current problem in developing countries. The household drinking water storage container is one source of contamination and should therefore be cleaned regularly. First, the present study investigated contextual factors that stimulate or inhibit the development of habitual cleaning of drinking water storage containers with soap and water. Second, based on the Risk, Attitudes, Norms, Abilities, and Self-regulation (RANAS) Model of behavior, the study aimed to determine which sociopsychological factors should be influenced by an intervention to promote habitual cleaning. In a cross-sectional study, 905 households in rural Benin were interviewed by structured face-to-face interviews. A forced-entry regression analysis was used to determine potential contextual factors related to habitual cleaning. Subsequently, a hierarchical regression was conducted with the only relevant contextual factor entered in the first step (R2 = 6.7%) and the sociopsychological factors added in the second step (R2 = 62.5%). Results showed that households using a clay container for drinking water storage had a significantly weaker habit of cleaning their water storage containers with soap and water than did households using other types of containers (β = -0.10). The most important sociopsychological predictors of habitual cleaning were commitment (β = 0.35), forgetting (β = -0.22), and self-efficacy (β = 0.14). The combined investigation of contextual and sociopsychological factors proved beneficial in terms of developing intervention strategies. Possible interventions based on these findings are recommended.

  3. Contact allergens and irritants in household washing and cleaning products.

    PubMed

    Magnano, Michela; Silvani, Simonetta; Vincenzi, Colombina; Nino, Massimiliano; Tosti, Antonella

    2009-12-01

    Household cleaning products often contain potential allergens and irritants but allergic contact dermatitis from these products in general consumers is rarely reported in the literature. The purpose of this study was to evaluate the presence of irritants and allergens as indicated on the labels or on the product information found on the website of household cleaning products marketed in Italy. We examined the labels and the product information of 291 liquid household washing and cleaning products, including 43 washing-up liquids, 63 laundry detergents, 61 fabric conditioners, 47 spray detergents, and 77 hard surface cleaning products. We obtained the data from the product information found on the websites for 263 products and directly on the product packages for 28 products. For each product we specifically recorded the presence of surfactants, preservatives, and fragrances listed in Annex III of Directive 76/768/EEC. The websites of two Italian brands do not respect EU regulations as they provide product information only with bar codes of the products. Preservatives and fragrances are the main allergens declared in the label of household cleaning products with methylchloroisothiazolinone/methylisothiazolinone (MCI/MI) listed in 35.7% and limonene in 43.6% of the products. Surfactants were listed in 16.5% of the studied products. Our study shows that household cleaning products in Italian market contain several allergens, particularly preservatives and fragrances. For consumers, at least in Italy, it may not be easy to retrieve product information from the website for two widely sold brands. The information had to be taken from the actual package.

  4. PILOT STUDY: THE TAMPA ASTHMATIC CHILDREN'S STUDY (TACS)

    EPA Science Inventory

    The Tampa Asthmatic Children's Study (TACS) was a pilot research study that focused on developing and evaluating air pollution exposure assessment methods and participant recruiting tools for children in the age range of 1-5 years old. The pilot study focused on (a) simple, cost-...

  5. Cleaning agents and asthma.

    PubMed

    Quirce, S; Barranco, P

    2010-01-01

    Although cleaners represent a significant part of the working population worldwide, they remain a relatively understudied occupational group. Epidemiological studies have shown an association between cleaning work and asthma, but the risk factors are uncertain. Cleaning workers are exposed to a large variety of cleaning products containing both irritants and sensitizers, as well as to common indoor allergens and pollutants. Thus, the onset or aggravation of asthma in this group could be related to an irritant-induced mechanism or to specific sensitization. The main sensitizers contained in cleaning products are disinfectants, quaternary ammonium compounds (such as benzalkonium chloride), amine compounds, and fragrances.The strongest airway irritants in cleaning products are bleach (sodium hypochlorite), hydrochloric acid, and alkaline agents (ammonia and sodium hydroxide), which are commonly mixed together. Exposure to the ingredients of cleaning products may give rise to both new-onset asthma, with or without a latency period, and work-exacerbated asthma. High-level exposure to irritants may induce reactive airways dysfunction syndrome. Cleaning workers may also have a greater relative risk of developing asthma due to prolonged low-to-moderate exposure to respiratory irritants. In addition, asthma-like symptoms without confirmed asthma are also common after exposure to cleaning agents. In many cleaners, airway symptoms induced by chemicals and odors cannot be explained by allergic or asthmatic reactions. These patients may have increased sensitivity to inhaled capsaicin, which is known to reflect sensory reactivity, and this condition is termed airway sensory hyperreactivity.

  6. Field-Scale Evaluation of Monitored Natural Attenuation for Dissolved Chlorinated Solvent Plumes

    DTIC Science & Technology

    2009-04-01

    biological in-situ treatment, an air sparging pilot study, and a phytoremediation study. The innovative technology studies were conducted within the source... phytoremediation (June to September 1997), reductive anaerobic biological in-situ treatment technology (RABITT; 1998), and groundwater recirculation wells...u g / L ) Measured Concentrations in 1381MWS09 Air Sparge Pilot Test (1996/1997) Phytoremediation Pilot Test (1997) RABITT Pilot Test (1998

  7. The Necessity of ASEAN Community in Producing Pilots

    ERIC Educational Resources Information Center

    Saowaros, Thanoo; Puncreobutr, Vichian

    2016-01-01

    The main objectives of this study are to identify the reasons for the shortage of pilots; the necessity of producing Pilots and the obstacles and problems faced by ASEAN Community in producing pilots. The study is conducted by official documents, observations, in-depth interview from personnel who are working for Airports Authority of Thailand,…

  8. SPEEDIER Project. Preliminary Report on Social Studies Pilot Projects.

    ERIC Educational Resources Information Center

    Myers, Charles B.; And Others

    This preliminary report describes five social studies pilot programs in the counties of Dauphin, Lancaster, Lebanon, and York, Pennsylvania. It is expected that these pilot endeavors will affect educators in the counties served by SPEEDIER as follows: 1) increase understanding of the newer content, ideas, and strategies in the pilot programs; 2)…

  9. Cleaning of titanium substrates after application in a bioreactor.

    PubMed

    Fingerle, Mathias; Köhler, Oliver; Rösch, Christina; Kratz, Fabian; Scheibe, Christian; Davoudi, Neda; Müller-Renno, Christine; Ziegler, Christiane; Huster, Manuel; Schlegel, Christin; Ulber, Roland; Bohley, Martin; Aurich, Jan C

    2015-03-10

    Plain and microstructured cp-titanium samples were studied as possible biofilm reactor substrates. The biofilms were grown by exposition of the titanium samples to bacteria in a flow cell. As bacteria the rod shaped gram negative Pseudomonas fluorescens and the spherical gram negative Paracoccus seriniphilus were chosen. Afterward, the samples were cleaned in subsequent steps: First, with a standard solvent based cleaning procedure with acetone, isopropanol, and ultrapure water and second by oxygen plasma sputtering. It will be demonstrated by means of x-ray photoelectron spectroscopy, fluorescence microscopy, and confocal laser scanning microscopy that oxygen plasma cleaning is a necessary and reliant tool to fully clean and restore titanium surfaces contaminated with a biofilm. The microstructured surfaces act beneficial to biofilm growth, while still being fully restorable after biofilm contamination. Scanning electron microscopy images additionally show, that the plasma process does not affect the microstructures. The presented data show the importance of the cleaning procedure. Just using solvents does not remove the biofilm and all its components reliably while a cleaning process by oxygen plasma regenerates the surfaces.

  10. Pilot Study: Foam Wedge Chin Support Static Tolerance Testing

    DTIC Science & Technology

    2017-10-24

    AFRL-SA-WP-SR-2017-0026 Pilot Study : Foam Wedge Chin Support Static Tolerance Testing Austin M. Fischer, BS1; William W...COVERED (From – To) April – October 2017 4. TITLE AND SUBTITLE Pilot Study : Foam Wedge Chin Support Static Tolerance Testing 5a. CONTRACT NUMBER...prototype to mitigate the increase in helmet weight and forward center of gravity. The purpose of this pilot study was to determine the feasibility and

  11. Cleaning frequency and the microbial load in ice-cream.

    PubMed

    Holm, Sonya; Toma, Ramses B; Reiboldt, Wendy; Newcomer, Chris; Calicchia, Melissa

    2002-07-01

    This study investigates the efficacy of a 62 h cleaning frequency in the manufacturing of ice-cream. Various product and product contact surfaces were sampled progressively throughout the time period between cleaning cycles, and analyzed for microbial growth. The coliform and standard plate counts (SPC) of these samples did not vary significantly over time after 0, 24, 48, or 62 h from Cleaning in Place (CiP). Data for product contact surfaces were significant for the SPC representing sample locations. Some of the variables in cleaning practices had significant influence on microbial loads. An increase in the number of flavors manufactured caused a decrease in SPC within the 24 h interval, but by the 48 h interval the SPC increased. More washouts within the first 24 h interval were favorable, as indicated by decreased SPC. The more frequently the liquefier was sanitized within the 62 h interval, the lower the SPC. This study indicates that food safety was not compromised and safety practices were effectively implemented throughout the process.

  12. An analytical study of aircraft lateral-directional handling qualities using pilot models

    NASA Technical Reports Server (NTRS)

    Adams, J. J.; Moore, F. L.

    1976-01-01

    A procedure for predicting lateral-directional pilot ratings on the basis of the characteristics of the pilot model and the closed-loop system characteristics is demonstrated. A correlation is shown to exist between experimentally obtained pilot ratings and the computed pilot ratings.

  13. Effectiveness of HVAC duct cleaning procedures in improving indoor air quality.

    PubMed

    Ahmad, I; Tansel, B; Mitrani, J D

    2001-12-01

    Indoor air quality has become one of the most serious environmental concerns as an average person spends about 22 hr indoors on a daily basis. The study reported in this article, was conducted to determine the effectiveness of three commercial HVAC (Heating Ventilation Air Conditioning) duct cleaning processes in reducing the level of airborne particulate matter and viable bioaerosols. The three HVAC sanitation processes were: (1) Contact method (use of conventional vacuum cleaning of interior duct surfaces); (2) Air sweep method (use of compressed air to dislodging dirt and debris); (3) Rotary brush method (insertion of a rotary brush into the ductwork to agitate and dislodge the debris). Effectiveness of these sanitation processes was evaluated in terms of airborne particulate and viable bioaerosol concentrations in residential homes. Eight identical homes were selected in the same neighborhood. Two homes were cleaned using each procedure and two were used as controls. It was found that both particle count readings and bioaerosol concentrations were higher when cleaning was being performed than before or after cleaning, which suggests that dirt, debris and other pollutants may become airborne as a result of disturbances caused by the cleaning processes. Particle count readings at 0.3 micron size were found to have increased due to cigarette smoking. Particle counts at 1.0 micron size were reduced due to HVAC duct cleaning. Post-level bioaerosol concentrations, taken two days after cleaning, were found to be lower than the pre-level concentrations suggesting that the cleaning procedures were effective to some extent. Homes cleaned with the Air Sweep procedure showed the highest degree of reduction in bioaerosol concentration among the three procedures investigated.

  14. Adenosine triphosphate bioluminescence for bacteriological surveillance and reprocessing strategies for minimizing risk of infection transmission by duodenoscopes

    PubMed Central

    Sethi, Saurabh; Huang, Robert J.; Barakat, Monique T.; Banaei, Niaz; Friedland, Shai; Banerjee, Subhas

    2017-01-01

    Background/Aims Recent outbreaks of duodenoscope-transmitted infections underscore the importance of adequate endoscope reprocessing. Adenosine triphosphate (ATP) bioluminescence testing allows rapid evaluation of endoscopes for bacteriological/biological residue. In this prospective study we evaluate the utility of ATP in bacteriological surveillance, and the effects of endoscopy staff education and dual cycles of cleaning and high-level disinfection (HLD) on endoscope reprocessing. Methods ATP bioluminescence was measured after pre-cleaning, manual cleaning and HLD on rinsates from suction-biopsy channels of all endoscopes and elevator channels of duodenoscopes/linear echoendoscopes after use. ATP bioluminescence was re-measured in duodenoscopes (1) after re-education and competency testing of endoscopy staff, and subsequently (2) after 2 cycles of pre-cleaning and manual cleaning and single cycle of HLD, or (3) after 2 cycles of pre-cleaning, manual cleaning and HLD. Results The ideal ATP bioluminescence benchmark of <200 relative light units (RLUs) after manual cleaning was achieved from suction-biopsy channel rinsates of all endoscopes, but 9 of 10 duodenoscope elevator channel rinsates failed to meet this benchmark. Re-education reduced RLUs in duodenoscope elevator channel rinsates after pre-cleaning (23218.0 vs 1340.5 RLUs, p<0.01) and HLD (177.0 vs 12.0 RLUs, p<0.01). After 2 cycles of manual cleaning/HLD, duodenoscope elevator channel RLUs achieved levels similar to sterile water, with corresponding negative cultures. Conclusions ATP testing offers a rapid, inexpensive alternative for detection of endoscope microbial residue. Re-education of endoscopy staff and 2 cycles of cleaning and HLD decrease elevator channel RLUs to levels similar to sterile water and may therefore minimize the risk of transmission of infections by duodenoscopes. PMID:27818222

  15. Effect of cleaning status on accuracy and precision of oxygen flowmeters of various ages.

    PubMed

    Fissekis, Stephanie; Hodgson, David S; Bello, Nora M

    2017-07-01

    To evaluate oxygen flowmeters for accuracy and precision, assess the effects of cleaning and assess conformity to the American Society for Testing Materials (ASTM) standards. Experimental study. The flow of oxygen flowmeters from 31 anesthesia machines aged 1-45 years was measured before and after cleaning using a volumetric flow analyzer set at 0.5, 1.0, 2.0, 3.0, and 4.0 L minute -1 . A general linear mixed models approach was used to assess flow accuracy and precision. Flowmeters 1 year of age delivered accurate mean oxygen flows at all settings regardless of cleaning status. Flowmeters ≥5 years of age underdelivered at flows of 3.0 and 4.0 L minute -1 . Flowmeters ≥12 years underdelivered at flows of 2.0, 3.0 and 4.0 L minute -1 prior to cleaning. There was no evidence of any beneficial effect of cleaning on accuracy of flowmeters 5-12 years of age (p > 0.22), but the accuracy of flowmeters ≥15 years of age was improved by cleaning (p < 0.05). Regardless of age, cleaning increased precision, decreasing flow variability by approximately 17%. Nine of 31 uncleaned flowmeters did not meet ASTM standards. After cleaning, a different set of nine flowmeters did not meet standards, including three that had met standards prior to cleaning. Older flowmeters were more likely to underdeliver oxygen, especially at higher flows. Regardless of age, cleaning decreased flow variability, improving precision. However, flowmeters still may fail to meet ASTM standards, regardless of cleaning status. Cleaning anesthesia machine oxygen flowmeters improved precision for all tested machines and partially corrected inaccuracies in flowmeters ≥15 years old. A notable proportion of flowmeters did not meet ASTM standards. Cleaning did not ensure that they subsequently conformed to ASTM standards. We recommend annual flow output validation to identify whether flowmeters are acceptable for continued clinical use. Copyright © 2017 Association of Veterinary Anaesthetists and American College of Veterinary Anesthesia and Analgesia. Published by Elsevier Ltd. All rights reserved.

  16. Dynamic Tunnel Usability Study: Format Recommendations for Synthetic Vision System Primary Flight Displays

    NASA Technical Reports Server (NTRS)

    Arthur, Jarvis J., III; Prinzel, Lawrence J., III; Kramer, Lynda J.; Bailey, Randall E.

    2006-01-01

    A usability study evaluating dynamic tunnel concepts has been completed under the Aviation Safety and Security Program, Synthetic Vision Systems Project. The usability study was conducted in the Visual Imaging Simulator for Transport Aircraft Systems (VISTAS) III simulator in the form of questionnaires and pilot-in-the-loop simulation sessions. Twelve commercial pilots participated in the study to determine their preferences via paired comparisons and subjective rankings regarding the color, line thickness and sensitivity of the dynamic tunnel. The results of the study showed that color was not significant in pilot preference paired comparisons or in pilot rankings. Line thickness was significant for both pilot preference paired comparisons and in pilot rankings. The preferred line/halo thickness combination was a line width of 3 pixels and a halo of 4 pixels. Finally, pilots were asked their preference for the current dynamic tunnel compared to a less sensitive dynamic tunnel. The current dynamic tunnel constantly gives feedback to the pilot with regard to path error while the less sensitive tunnel only changes as the path error approaches the edges of the tunnel. The tunnel sensitivity comparison results were not statistically significant.

  17. Effects of alcohol on pilot performance in simulated flight

    NASA Technical Reports Server (NTRS)

    Billings, C. E.; Demosthenes, T.; White, T. R.; O'Hara, D. B.

    1991-01-01

    Ethyl alcohol's known ability to produce reliable decrements in pilot performance was used in a study designed to evaluate objective methods for assessing pilot performance. Four air carrier pilot volunteers were studied during eight simulated flights in a B727 simulator. Total errors increased linearly and significantly with increasing blood alcohol. Planning and performance errors, procedural errors and failures of vigilance each increased significantly in one or more pilots and in the group as a whole.

  18. Efficacy and safety profile of antibiotic prophylaxis usage in clean and clean-contaminated plastic and reconstructive surgery: a meta-analysis of randomized controlled trials.

    PubMed

    Zhang, Yi; Dong, Jiasheng; Qiao, Yufei; He, Jinguang; Wang, Tao; Ma, Sunxiang

    2014-01-01

    There is no consensus with regard to antibiotic prophylaxis usage in clean and clean-contaminated plastic and reconstructive surgery. This meta-analysis sought to assess the efficacy and safety of antibiotic prophylaxis and to determine appropriate duration of prophylaxis. An English language literature search was conducted using PubMed and the Cochrane Collaboration for randomized controlled trials (RCTs) that evaluate the use of antibiotic prophylaxis to prevent postoperative surgical site infection (SSI) in patients undergoing clean and clean-contaminated plastic and reconstructive surgery. Data from intention-to-treat analyses were used where available. For the dichotomous data, results for each study were odds ratio (OR) with 95% confidence interval (CI) and combined for meta-analysis using the Mantel-Haenszel method or the DerSimonian and Laird method. Study quality was critically appraised by 2 reviewers using established criteria. STATA version 12 was used for meta-analyses. Twelve RCTs involving 2395 patients were included, of which 8 trials were considered to be of high methodological quality. Effect of antibiotic prophylaxis in plastic and reconstructive surgery was found favorable over placebo in SSI prevention (13 studies; 2449 participants; OR, 0.53; 95% CI, 0.4-0.7; P < 0.01) and the other wound complication (OWC) prevention (9 studies; 1843 participants; OR, 0.36; 95% CI, 0.15-0.84; P < 0.02). Subgroup analysis performed according to surgical wound type or the duration of prophylaxis did not modify the results except for the OWC with short-term antibiotic treatment. Compared with short-term antibiotic prophylaxis, long-term administration showed no evidence of a difference in risk of SSI (7 studies; 1012 participants; OR, 0.99; 95% CI, 0.63-1.55; P < 0.95), OWC (5 studies; 824 participants; OR, 0.92; 95% CI, 0.46-1.86; P < 0.82), and adverse event relative to antibiotic administration (3 studies; 653 participants; OR, 0.23; 95% CI, 0.01-4.92; P < 0.35). This meta-analysis of RCTs provides evidence supporting that antibiotic prophylaxis reduced postoperative SSI in clean plastic surgeries with high-risk factors and clean-contaminated plastic surgeries. Besides, a short-course administration regimen seemed to be of adequate efficacy and safety. High-quality prospective trials on larger scale are needed to further confirm these findings.

  19. Performing a urine dipstick test with a clean-catch urine sample is an accurate screening method for urinary tract infections in young infants.

    PubMed

    Herreros, María Luisa; Tagarro, Alfredo; García-Pose, Araceli; Sánchez, Aida; Cañete, Alfonso; Gili, Pablo

    2018-01-01

    This study evaluated using urine dipstick tests with the clean-catch method to screen for urinary tract infection (UTI) in febrile infants under 90 days of age. We carried out a comparative diagnostic accuracy study of infants under 90 days old, who were studied for unexplained fever without any source, in the emergency room of a hospital in Madrid from January 2011 to January 2013. We obtained matched samples of urine using two different methods: a clean-catch, standardised stimulation technique and catheterisation collection. The results of the leucocyte esterase test and nitrite test were compared with their urine cultures. We obtained 60 pairs of matched samples. A combined analysis of leukocyte esterase and, or, nitrites yielded a sensitivity of 86% and a specificity of 80% for the diagnosis of UTIs in clean-catch samples. The sensitivity of leukocyte esterase and, or, nitrites in samples obtained by catheterisation were not statistically different to the clean-catch samples (p = 0.592). Performing urine dipstick tests using urine samples obtained by the clean-catch method was an accurate screening test for diagnosing UTIs in febrile infants of less than 90 days old. This provided a good alternative to bladder catheterisation when screening for UTIs. ©2017 Foundation Acta Paediatrica. Published by John Wiley & Sons Ltd.

  20. Fragrance materials in asthma: a pilot study using a surrogate aerosol product.

    PubMed

    Vethanayagam, Dilini; Vliagoftis, Harissios; Mah, Dennell; Beach, Jeremy; Smith, Ladd; Moqbel, Redwan

    2013-11-01

    Many household products contain fragrances. Little is known about exposure to fragrances on human health, particularly within the airways. This study aimed to evaluate how common household fragrance products (i.e. air fresheners, cleaning products) affect people with asthma, who frequently report sensitivity to these products. Many of these products have volatile organic compounds or semi-volatile organic compounds. This study evaluated nine fragrance materials in an aerosol formulation to assess effects on airway physiology, airway inflammation and symptom perception in normal controls and those with asthma. The effects of fragrances were evaluated in people without asthma, people with mild asthma and people with moderate asthma in a four-way crossover placebo-controlled study. Subjects were exposed twice to a fragranced aerosol and twice to a placebo aerosol (15 and 30 min each). Subjects completed a questionnaire for 29 symptoms during and up to 3 h after each exposure scenario. Spirometry was performed prior to and 3 h post-exposure; sputum induction was conducted 3 h post-exposure. Nasal symptoms showed the greatest frequency of response in all three subject groups, and moderate asthmatics reported the greatest symptom severity and symptom types. No significant differences were noted in physiology or cellular inflammation. A trend for increased symptoms was noted in moderate asthmatics, suggesting that asthma severity may play a factor in fragrance sensitivity.

  1. An experimental study of the effect of a pilot flame on technically pre-mixed, self-excited combustion instabilities

    NASA Astrophysics Data System (ADS)

    O'Meara, Bridget C.

    Combustion instabilities are a problem facing the gas turbine industry in the operation of lean, pre-mixed combustors. Secondary flames known as "pilot flames" are a common passive control strategy for eliminating combustion instabilities in industrial gas turbines, but the underlying mechanisms responsible for the pilot flame's stabilizing effect are not well understood. This dissertation presents an experimental study of a pilot flame in a single-nozzle, swirl-stabilized, variable length atmospheric combustion test facility and the effect of the pilot on combustion instabilities. A variable length combustor tuned the acoustics of the system to excite instabilities over a range of operating conditions without a pilot flame. The inlet velocity was varied from 25 -- 50 m/s and the equivalence ratio was varied from 0.525 -- 0.65. This range of operating conditions was determined by the operating range of the combustion test facility. Stability at each operating condition and combustor length was characterized by measurements of pressure oscillations in the combustor. The effect of the pilot flame on the magnitude and frequency of combustor stability was then investigated. The mechanisms responsible for the pilot flame effect were studied using chemiluminescence flame images of both stable and unstable flames. Stable flame structure was investigated using stable flame images of CH* chemiluminescence emission. The effect of the pilot on stable flame metrics such as flame length, flame angle, and flame width was investigated. In addition, a new flame metric, flame base distance, was defined to characterize the effect of the pilot flame on stable flame anchoring of the flame base to the centerbody. The effect of the pilot flame on flame base anchoring was investigated because the improved stability with a pilot flame is usually attributed to improved flame anchoring through the recirculation of hot products from the pilot to the main flame base. Chemiluminescence images of unstable flames were used to identify several instability mechanisms and infer how these mechanisms are affected by the pilot flame. Flame images of cases in which the pilot flame did not eliminate the instability were investigated to understand why the pilot flame is not effective in certain cases. The phase of unstable pilot flame oscillations was investigated to determine how the phase of pilot flame oscillations may affect its ability to interfere with instability mechanisms in the main flame. A forced flame response study was conducted to determine the effect of inlet velocity oscillation amplitude on the pilot flame. The flame response was characterized by measurements of velocity oscillations in the injector and chemiluminescence intensity oscillations determined from flame images. As the forcing amplitude increases, the pilot flame's effect on the flame transfer function magnitude becomes weaker. Flame images show that as the forcing amplitude increases, the pilot flame oscillations increase, leading to an ineffective pilot. The results of the flame response portion of this study highlight the effect of instability amplitude on the ability of a pilot flame to eliminate a combustion instability.

  2. Measuring the effect of enhanced cleaning in a UK hospital: a prospective cross-over study

    PubMed Central

    Dancer, Stephanie J; White, Liza F; Lamb, Jim; Girvan, E Kirsty; Robertson, Chris

    2009-01-01

    Background Increasing hospital-acquired infections have generated much attention over the last decade. There is evidence that hygienic cleaning has a role in the control of hospital-acquired infections. This study aimed to evaluate the potential impact of one additional cleaner by using microbiological standards based on aerobic colony counts and the presence of Staphylococcus aureus including meticillin-resistant S. aureus. Methods We introduced an additional cleaner into two matched wards from Monday to Friday, with each ward receiving enhanced cleaning for six months in a cross-over design. Ten hand-touch sites on both wards were screened weekly using standardised methods and patients were monitored for meticillin-resistant S. aureus infection throughout the year-long study. Patient and environmental meticillin-resistant S. aureus isolates were characterised using molecular methods in order to investigate temporal and clonal relationships. Results Enhanced cleaning was associated with a 32.5% reduction in levels of microbial contamination at hand-touch sites when wards received enhanced cleaning (P < 0.0001: 95% CI 20.2%, 42.9%). Near-patient sites (lockers, overbed tables and beds) were more frequently contaminated with meticillin-resistant S. aureus/S. aureus than sites further from the patient (P = 0.065). Genotyping identified indistinguishable strains from both hand-touch sites and patients. There was a 26.6% reduction in new meticillin-resistant S. aureus infections on the wards receiving extra cleaning, despite higher meticillin-resistant S. aureus patient-days and bed occupancy rates during enhanced cleaning periods (P = 0.032: 95% CI 7.7%, 92.3%). Adjusting for meticillin-resistant S. aureus patient-days and based upon nine new meticillin-resistant S. aureus infections seen during routine cleaning, we expected 13 new infections during enhanced cleaning periods rather than the four that actually occurred. Clusters of new meticillin-resistant S. aureus infections were identified 2 to 4 weeks after the cleaner left both wards. Enhanced cleaning saved the hospital £30,000 to £70,000. Conclusion Introducing one extra cleaner produced a measurable effect on the clinical environment, with apparent benefit to patients regarding meticillin-resistant S. aureus infection. Molecular epidemiological methods supported the possibility that patients acquired meticillin-resistant S. aureus from environmental sources. These findings suggest that additional research is warranted to further clarify the environmental, clinical and economic impact of enhanced hygienic cleaning as a component in the control of hospital-acquired infection. PMID:19505316

  3. ToF-SIMS Investigation of the Effectiveness of Acid-Cleaning procedures for Genesis Solar Wind Collectors

    NASA Technical Reports Server (NTRS)

    Goreva, Y. S.; Humanyun, M.; Burnett, D. S.; Jurewicz, A. J.; Gonzalez, C. P.

    2014-01-01

    ToF-SIMS images of Genesis sample surfaces contain an incredible amount of important information, but they also show that the crash-derived surface contamination has many components, presenting a challenge to cleaning. Within the variability, we have shown that there are some samples which appear to be clean to begin with, e.g. 60471, and some are more contaminated. Samples 60493 and 60500 are a part of a focused study of the effectiveness of aqua regia and/or sulfuric acid cleaning of small flight Si implanted with Li-6 using ToF-SIMS.

  4. The Principle and the Application of Self-cleaning Anti-pollution Coating in Power System

    NASA Astrophysics Data System (ADS)

    Zhao, Y. J.; Zhang, Z. B.; Liu, Y.; Wang, J. H.; Teng, J. L.; Wu, L. S.; Zhang, Y. L.

    2017-11-01

    The common problem existed in power system is analyzed in this paper. The main reason for the affection of the safe and stable operation to power equipment is flash-over caused by dirt and discharge. Using the self-cleaning anti-pollution coating in the power equipment surface is the key to solve the problem. In the work, the research progress and design principle about the self-cleaning anti-pollution coating was summarized. Furthermore, the preparation technology was also studied. Finally, the application prospect of hard self-cleaning anti-pollution coating in power system was forecast.

  5. Controlling road rage : a literature review and pilot study

    DOT National Transportation Integrated Search

    1999-06-01

    This report discusses results of a literature review and pilot study on how to prevent aggressive driving and road rage. The study "Controlling Road Rage: A Literature Review and Pilot Study" defines road rage as "an incident in which an angry or imp...

  6. Physiological studies on air tanker pilots flying forest fire retardant missions.

    DOT National Transportation Integrated Search

    1968-10-01

    Pre-flight and post-flight studies were carried out on five air tanker pilots; in-flight studies were carried out on four of these five pilots. Pre- and post-flight studies consisted of a questionnaire and determinations of blood pressure, psychomoto...

  7. Proteomic analysis and comparison of the biopsy and autopsy specimen of human brain temporal lobe.

    PubMed

    He, Sizhi; Wang, Qingsong; He, Jintang; Pu, Hai; Yang, Wei; Ji, Jianguo

    2006-09-01

    The proteomic study on human temporal lobe can help us to understand the physiological function of CNS in normal as well as in pathological state. Proteomic tools are potent for the assessment of protein stability post mortem. In this pilot study, the human temporal lobe biopsy specimen with chronic pharmacoresistant temporal lobe epilepsy (TLE) and autopsy specimen in control were separated by 2-DE. Using MALDI-TOF-MS and MS/MS, 375 protein spots were identified which were the products of 267 genes. Six down-regulated and 23 up-regulated protein spots in the autopsy specimen were ascertained after the gel image analysis with the ImageMaster software. A number of proteins that include neurotransmitter metabolic and glycolytic enzymes, cytoprotective proteins and cytoskeleton were found decreased while the precursor of apolipoprotein A-I increased in the TLE brain. We tried several methods to prepare the protein samples and found that DNase and RNase treatment, ultracentrifugation and Amersham clean-up kit purification can improve gel separation quality. This work optimized the sample preparation method and constructed a primary protein database of human temporal lobe and found some proteins with remarkable level change probably involved in the post-mortem process and chronic pharmacoresistant TLE pathogenesis.

  8. Machinery safety of lathe machine using SHARP-systemic human action reliability procedure: a pilot case study in academic laboratory

    NASA Astrophysics Data System (ADS)

    Suryoputro, M. R.; Sari, A. D.; Sugarindra, M.; Arifin, R.

    2017-12-01

    This research aimed to understand the human reliability analysis, to find the SHARP method with its functionality on case study and also emphasize the practice in Lathe machine, continued with identifying improvement that could be made to the existing safety system. SHARP comprises of 7 stages including definition, screening, breakdown, representation, impact assessment, quantification and documentation. These steps were combined and analysed using HIRA, FTA and FMEA. HIRA analysed the lathe at academic laboratory showed the level of the highest risk with a score of 9 for the activities of power transmission parts and a score of 6 for activities which shall mean the moving parts required to take action to reduce the level of risk. Hence, the highest RPN values obtained in the power transmission activities with a value of 18 in the power transmission and then the activities of moving parts is 12 and the activities of the operating point of 8. Thus, this activity has the highest risk of workplace accidents in the operation. On the academic laboratory the improvement made on the engineering control initially with a machine guarding and completed with necessary administrative controls (SOP, work permit, training and routine cleaning) and dedicated PPEs.

  9. A flux-enhancing forward osmosis-nanofiltration integrated treatment system for the tannery wastewater reclamation.

    PubMed

    Pal, Parimal; Chakrabortty, Sankha; Nayak, Jayato; Senapati, Suman

    2017-06-01

    Effective treatment of tannery wastewater prior to discharge to the environment as per environmental regulations remains a big challenge despite efforts to bring down the concentrations of the pollutants which are often quite high as measured in terms of chemical oxygen demand (7800 mg/L), total dissolved solids (5400 mg/L), chloride (4260 mg/L), sulphides (250 mg/L) and chromium. A pilot-scale forward osmosis and nanofiltration integrated closed loop system was developed for continuous reclamation of clean water from tannery wastewater at a rate of 52-55 L/m 2 /h at 1.6 bar pressure. The low-cost draw solution was 0.8 M NaCl solution. Continuous recovery for recycling the draw solute was done by nanofiltration of diluted draw solution at an operating pressure of 12 bar and volumetric cross-flow rate of 700 L/h. Fouling study revealed that the specific flat-sheet design of cross-flow forward osmosis module with counter current flow of feed and draw solution prevents the build-up of concentration polarization, thus enabling long-term filtration in continuous mode of operation without significant membrane fouling. This study culminates in the development of a compact, efficient and low-cost industrial wastewater treatment and reclamation technology.

  10. Clean Energy Manufacturing Analysis Center (CEMAC) 2015 Research Highlights

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Woodhouse, Michael; Mone, Christopher; Chung, Donald

    2016-03-01

    CEMAC has conducted four major studies on the manufacturing of clean energy technologies. Three of these focused on the end product: solar photovoltaic modules, wind turbines, and automotive lithium-ion batteries. The fourth area focused on a key material for manufacturing clean energy technologies, carbon fiber. This booklet summarizes key findings of CEMAC work to date, describes CEMAC's research methodology, and describes work to come.

  11. Cleaning Study of Genesis Sample 60487

    NASA Technical Reports Server (NTRS)

    Kuhlman, Kim R.; Rodriquez, M. C.; Gonzalez, C. P.; Allton, J. H.; Burnett, D. S.

    2013-01-01

    The Genesis mission collected solar wind and brought it back to Earth in order to provide precise knowledge of solar isotopic and elemental compositions. The ions in the solar wind were stopped in the collectors at depths on the order of 10 to a few hundred nanometers. This shallow implantation layer is critical for scientific analysis of the composition of the solar wind and must be preserved throughout sample handling, cleaning, processing, distribution, preparation and analysis. Particles of Genesis wafers, brine from the Utah Testing Range and an organic film have deleterious effects on many of the high-resolution instruments that have been developed to analyze the implanted solar wind. We have conducted a correlative microscopic study of the efficacy of cleaning Genesis samples with megasonically activated ultrapure water and UV/ozone cleaning. Sample 60487, the study sample, is a piece of float-zone silicon from the B/C array approximately 4.995mm x 4.145 mm in size

  12. Lessons from a One-to-One Laptop Pilot

    ERIC Educational Resources Information Center

    Peterson, Lana; Scharber, Cassandra

    2017-01-01

    The purpose of this study was to document the process one district used to design, develop, and implement a one-to-one pilot at its high school as part of its broader commitment to contemporary learning. Specifically, this qualitative case study (a) outlines the process of the laptop pilot, (b) describes the pilot implementation experience for…

  13. Membrane cleaning with ultrasonically driven bubbles.

    PubMed

    Reuter, Fabian; Lauterborn, Sonja; Mettin, Robert; Lauterborn, Werner

    2017-07-01

    A laboratory filtration plant for drinking water treatment is constructed to study the conditions for purely mechanical in situ cleaning of fouled polymeric membranes by the application of ultrasound. The filtration is done by suction of water with defined constant contamination through a membrane module, a stack of five pairs of flat-sheet ultrafiltration membranes. The short cleaning cycle to remove the cake layer from the membranes includes backwashing, the application of ultrasound and air flushing. A special geometry for sound irradiation of the membranes parallel to their surfaces is chosen. Two frequencies, 35kHz and 130kHz, and different driving powers are tested for their cleaning effectiveness. No cleaning is found for 35kHz, whereas good cleaning results are obtained for 130kHz, with an optimum cleaning effectiveness at moderate driving powers. Acoustic and optic measurements in space and time as well as analytical considerations and numerical calculations reveal the reasons and confirm the experimental results. The sound field is measured in high resolution and bubble structures are high-speed imaged on their nucleation sites as well as during their cleaning work at the membrane surface. The microscopic inspection of the membrane surface after cleaning shows distinct cleaning types in the cake layer that are related to specific bubble behaviour on the membrane. The membrane integrity and permeate quality are checked on-line by particle counting and turbidity measurement of the permeate. No signs of membrane damage or irreversible membrane degradation in permeability are detected and an excellent water permeate quality is retained. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Assessment of hospital daily cleaning practices using ATP bioluminescence in a developing country.

    PubMed

    Zambrano, Alejandra A; Jones, Alex; Otero, Paula; Ajenjo, Maria Cristina; Labarca, Jaime A

    2014-01-01

    Visual assessment of surfaces may not be enough to document the level of cleanliness in the hospital setting. It is necessary to introduce quantitative methods to document the results of this practice. To evaluate the efficacy of hospital terminal cleaning procedures, using an adenosine triphosphate (ATP) bioluminescence method in a teaching hospital. During 2008 we conducted an evaluation using ATP bioluminescence LIGHTNING MVP™ (Arquimed) of external and internal housekeeping service. After conducting an initial evaluation we implemented education of cleaning practices and finally we did a post intervention evaluation. Using chi-square method we compared prior versus after cleaning, quality of cleaning performed by external versus internal personnel, single versus double terminal cleaning procedures and prior versus after intervention. A finding of three RLU or less was considered a clean surface. We performed 198 evaluations in 33 patient units and nine OR. Internal personnel accomplished 25.37% of clean surfaces before and 80% after the education intervention (p=0.01). In contrast, external personnel obtained 68.8% before and 73.33% after intervention (p=0.3). This study suggests that visual assessment is not enough to ensure quality of the process and it is necessary to document the level of cleanliness by quantitative methods. Copyright © 2014 Elsevier Editora Ltda. All rights reserved.

  15. Diversity of anaerobic microbes in spacecraft assembly clean rooms.

    PubMed

    Probst, Alexander; Vaishampayan, Parag; Osman, Shariff; Moissl-Eichinger, Christine; Andersen, Gary L; Venkateswaran, Kasthuri

    2010-05-01

    Although the cultivable and noncultivable microbial diversity of spacecraft assembly clean rooms has been previously documented using conventional and state-of-the-art molecular techniques, the occurrence of obligate anaerobes within these clean rooms is still uncertain. Therefore, anaerobic bacterial communities of three clean-room facilities were analyzed during assembly of the Mars Science Laboratory rover. Anaerobic bacteria were cultured on several media, and DNA was extracted from suitable anaerobic enrichments and examined with conventional 16S rRNA gene clone library, as well as high-density phylogenetic 16S rRNA gene microarray (PhyloChip) technologies. The culture-dependent analyses predominantly showed the presence of clostridial and propionibacterial strains. The 16S rRNA gene sequences retrieved from clone libraries revealed distinct microbial populations associated with each clean-room facility, clustered exclusively within gram-positive organisms. PhyloChip analysis detected a greater microbial diversity, spanning many phyla of bacteria, and provided a deeper insight into the microbial community structure of the clean-room facilities. This study presents an integrated approach for assessing the anaerobic microbial population within clean-room facilities, using both molecular and cultivation-based analyses. The results reveal that highly diverse anaerobic bacterial populations persist in the clean rooms even after the imposition of rigorous maintenance programs and will pose a challenge to planetary protection implementation activities.

  16. EVALUATION OF PERSONAL COOLING DEVICES FOR A DIOXIN CLEAN-UP OPERATION

    EPA Science Inventory

    The study investigated the use of personal coolers to increase worker productivity and safety while working at elevated, ambient temperatures cleaning up dioxin contaminated soil.^The study included laboratory tests to measure the thermal characteristics of the chemical protectiv...

  17. Food safety knowledge, attitudes and practices of institutional food-handlers in Ghana.

    PubMed

    Akabanda, Fortune; Hlortsi, Eli Hope; Owusu-Kwarteng, James

    2017-01-06

    In large scale cooking, food is handled by many individuals, thereby increasing the chances of food contamination due to improper handling. Deliberate or accidental contamination of food during large scale production might endanger the health of consumers, and have very expensive repercussions on a country. The purpose of this study was to evaluate the food safety knowledge, attitudes, and practices among institutional food- handlers in Ghana. The study was conducted using a descriptive, cross-sectional survey of 29 institutions by conducting face to face interview and administration of questionnaire to two hundred and thirty-five (235) institutional food-handlers. The questionnaire was peer-reviewed and pilot tested in three institutions in the Upper East Region of Ghana, before the final version was distributed to food-handlers. The questionnaire was structured into five distinctive parts to collect information on (i) demographic characteristics, (ii) employees' work satisfaction, (iii) knowledge on food safety, (iv) attitudes towards food safety and (v) food hygiene practices. Majority of the food-handlers were between 41-50 years (39.1%). Female respondents were (76.6%). In our study, the food-handlers were knowledgeable about hygienic practices, cleaning and sanitation procedures. Almost all of the food-handlers were aware of the critical role of general sanitary practices in the work place, such as hand washing (98.7% correct answers), using gloves (77.9%), proper cleaning of the instruments/utensils (86.4%) and detergent use (72.8%). On disease transmission, the results indicates that 76.2% of the food- handlers did not know that Salmonella is a food borne pathogens and 70.6% did not know that hepatitis A is a food borne pathogen. However, 81.7% handlers agreed that typhoid fever is transmitted by food and 87.7% agreed that bloody diarrhea is transmitted by food. Logistic regression analysis testing four models showed statistically significant differences (p < 0.05), for models in which the explanatory variable was the level of education. In generally, the institutional food-handlers have satisfactory knowledge in food safety but this does not translate into strict hygienic practices during processing and handling food products.

  18. The stuff that dreams are made of: HIV-positive adolescents' aspirations for development.

    PubMed

    Hodes, Rebecca; Doubt, Jenny; Toska, Elona; Vale, Beth; Zungu, Nompumelelo; Cluver, Lucie

    2018-02-01

    The Sustainable Development Goals (SDGs) commit to strengthening collaborations between governments and civil society. Adolescents are among the key target populations for global development initiatives, but research studies and programmes rarely include their direct perspectives on how to promote health and wellbeing. This article explores how both the methods and the findings of participatory research provide insights into adolescents' aspirations across the domains of health and social development. It investigates how adolescents conceive of health and social services as interconnected, and how this reflects the multisectoral objectives of the SDGs. This research was conducted within a longitudinal, mixed-methods study of HIV-positive adolescents (n = 80 qualitative participants, n = 1060 quantitative interviews). Between November 2013 and February 2014, a participatory exercise - the "dream clinic" - was piloted with 25 adolescents in South Africa's Eastern Cape. Key themes were identified based on the insights shared by participants, and through visual and thematic analysis. These findings were explored through a second participatory exercise, "Yummy or crummy? You are the Mzantsi Wakho masterchef !," conducted in January 2016. Findings are described in relation to emerging quantitative results. Mixed methods explored associations between access to food, medicines, clean water and sanitation in HIV-positive adolescents' aspirations for development. The exercises produced practicable recommendations for innovations in development, based on associations between healthcare, food security, clean water and sanitation, while illustrating the value of partnership and collaboration (the objective of SDG17). Findings capture strong interlinkages between SDGs 2, 3 and 6 - confirming the importance of specific SDGs for HIV-positive adolescents. Study results informed the objectives of South Africa's National and Adolescent and Youth Health Policy (2017). Participatory research may be used to leverage the perspectives and experiences of adolescents. The methods described here provide potential for co-design and implementation of developmental initiatives to fulfil the ambitious mandate of the SDGs. They may also create new opportunities to strengthen the engagement of adolescents in policy and programming. © 2018 The Authors. Journal of the International AIDS Society published by John Wiley & sons Ltd on behalf of the International AIDS Society.

  19. Pilot Non-Conformance to Alerting System Commands

    NASA Technical Reports Server (NTRS)

    Pritchett, Amy R.; Hansman, R. John

    1997-01-01

    Instances of pilot non-conformance to alerting system commands have been identified in previous studies. Pilot non-conformance changes the final behavior of the system, and therefore may reduce actual performance from that anticipated. A simulator study has examined pilot non-conformance, using the task of collision avoidance during closely spaced parallel approaches as a case study. Consonance between the display and the alerting system was found to significantly improve subject agreement with automatic alerts. Based on these results, a more general discussion of the factors involved in pilot conformance is given, and design guidelines for alerting systems are given.

  20. Trade study comparing specimen chamber servicing methods for the Space Station Centrifuge Facility

    NASA Technical Reports Server (NTRS)

    Calvisi, Michael L.; Sun, Sidney C.

    1991-01-01

    The Specimen Chamber Service Unit, a component of the Space Station Centrifuge Facility, must provide a clean enclosure on a continuing basis for the facility's plant, rodent and primate specimens. The specimen chambers can become soiled and can require periodic servicing to maintain a clean environment for the specimens. Two methods of servicing the specimen chambers are discussed: washing the chambers with an on-board washer, or disposing of the soiled chambers and replacing them with clean ones. Many of these issues are addressed by developing several servicing options, using either cleaning or replacement as the method of providing clean specimen chambers, and then evaluating each option according to a set of established quantitative and qualitative criteria. Disposing and replacing the Specimen Chambers is preferable to washing them.

  1. Meissner effect in normal-superconducting proximity-contact double layers

    NASA Astrophysics Data System (ADS)

    Higashitani, Seiji; Nagai, Katsuhiko

    1995-02-01

    The Meissner effect in normal-superconducting proximity-contact double layers is discussed in the clean limit. The diamagnetic current is calculated using the quasi-classical Green's function. We obtain the quasi-classical Green's function linear in the vector potential in the proximity-contact double layers with a finite reflection coefficient at the interface. It is found that the diamagnetic current in the clean normal layer is constant in space, therefore, the magnetic field linearly decreases in the clean normal layer. We give an explicit expression for the screening length in the clean normal layer and study its temperature dependence. We show that the temperature dependence in the clean normal layer is considerably different from that in the dirty normal layer and agrees with a recent experiment in Au-Nb system.

  2. Pilot error in air carrier accidents: does age matter?

    PubMed

    Li, Guohua; Grabowski, Jurek G; Baker, Susan P; Rebok, George W

    2006-07-01

    The relationship between pilot age and safety performance has been the subject of research and controversy since the "Age 60 Rule" became effective in 1960. This study aimed to examine age-related differences in the prevalence and patterns of pilot error in air carrier accidents. Investigation reports from the National Transportation Safety Board for accidents involving Part 121 operations in the United States between 1983 and 2002 were reviewed to identify pilot error and other contributing factors. Accident circumstances and the presence and type of pilot error were analyzed in relation to pilot age using Chi-square tests. Of the 558 air carrier accidents studied, 25% resulted from turbulence, 21% from mechanical failure, 16% from taxiing events, 13% from loss of control at landing or takeoff, and 25% from other causes. Accidents involving older pilots were more likely to be caused by turbulence, whereas accidents involving younger pilots were more likely to be taxiing events. Pilot error was a contributing factor in 34%, 38%, 35%, and 34% of the accidents involving pilots ages 25-34 yr, 35-44 yr, 45-54 yr, and 55-59 yr, respectively (p = 0.87). The patterns of pilot error were similar across age groups. Overall, 26% of the pilot errors identified were inattentiveness, 22% flawed decisions, 22% mishandled aircraft kinetics, and 11% poor crew interactions. The prevalence and patterns of pilot error in air carrier accidents do not seem to change with pilot age. The lack of association between pilot age and error may be due to the "safe worker effect" resulting from the rigorous selection processes and certification standards for professional pilots.

  3. Evaluation of a pulsed-xenon ultraviolet room disinfection device for impact on contamination levels of methicillin-resistant Staphylococcus aureus.

    PubMed

    Jinadatha, Chetan; Quezada, Ricardo; Huber, Thomas W; Williams, Jason B; Zeber, John E; Copeland, Laurel A

    2014-04-07

    Healthcare-acquired infections with methicillin-resistant Staphylococcus aureus (MRSA) are a significant cause of increased mortality, morbidity and additional health care costs in United States. Surface decontamination technologies that utilize pulsed xenon ultraviolet light (PPX-UV) may be effective at reducing microbial burden. The purpose of this study was to compare standard manual room-cleaning to PPX-UV disinfection technology for MRSA and bacterial heterotrophic plate counts (HPC) on high-touch surfaces in patient rooms. Rooms vacated by patients that had a MRSA-positive polymerase chain reaction or culture during the current hospitalization and at least a 2-day stay were studied. 20 rooms were then treated according to one of two protocols: standard manual cleaning or PPX-UV. This study evaluated the reduction of MRSA and HPC taken from five high-touch surfaces in rooms vacated by MRSA-positive patients, as a function of cleaning by standard manual methods vs a PPX-UV area disinfection device. Colony counts in 20 rooms (10 per arm) prior to cleaning varied by cleaning protocol: for HPC, manual (mean = 255, median = 278, q1-q3 132-304) vs PPX-UV (mean = 449, median = 365, q1-q3 332-530), and for MRSA, manual (mean = 127; median = 28.5; q1-q3 8-143) vs PPX-UV (mean = 108; median = 123; q1-q3 14-183). PPX-UV was superior to manual cleaning for MRSA (adjusted incident rate ratio [IRR] = 7; 95% CI <1-41) and for HPC (IRR = 13; 95% CI 4-48). PPX-UV technology appears to be superior to manual cleaning alone for MRSA and HPC. Incorporating 15 minutes of PPX-UV exposure time to current hospital room cleaning practice can improve the overall cleanliness of patient rooms with respect to selected micro-organisms.

  4. Evaluation of a pulsed-xenon ultraviolet room disinfection device for impact on contamination levels of methicillin-resistant Staphylococcus aureus

    PubMed Central

    2014-01-01

    Background Healthcare-acquired infections with methicillin-resistant Staphylococcus aureus (MRSA) are a significant cause of increased mortality, morbidity and additional health care costs in United States. Surface decontamination technologies that utilize pulsed xenon ultraviolet light (PPX-UV) may be effective at reducing microbial burden. The purpose of this study was to compare standard manual room-cleaning to PPX-UV disinfection technology for MRSA and bacterial heterotrophic plate counts (HPC) on high-touch surfaces in patient rooms. Methods Rooms vacated by patients that had a MRSA-positive polymerase chain reaction or culture during the current hospitalization and at least a 2-day stay were studied. 20 rooms were then treated according to one of two protocols: standard manual cleaning or PPX-UV. This study evaluated the reduction of MRSA and HPC taken from five high-touch surfaces in rooms vacated by MRSA-positive patients, as a function of cleaning by standard manual methods vs a PPX-UV area disinfection device. Results Colony counts in 20 rooms (10 per arm) prior to cleaning varied by cleaning protocol: for HPC, manual (mean = 255, median = 278, q1-q3 132–304) vs PPX-UV (mean = 449, median = 365, q1-q3 332–530), and for MRSA, manual (mean = 127; median = 28.5; q1-q3 8–143) vs PPX-UV (mean = 108; median = 123; q1-q3 14–183). PPX-UV was superior to manual cleaning for MRSA (adjusted incident rate ratio [IRR] = 7; 95% CI <1-41) and for HPC (IRR = 13; 95% CI 4–48). Conclusion PPX-UV technology appears to be superior to manual cleaning alone for MRSA and HPC. Incorporating 15 minutes of PPX-UV exposure time to current hospital room cleaning practice can improve the overall cleanliness of patient rooms with respect to selected micro-organisms. PMID:24708734

  5. A first French assessment of population exposure to tetrachloroethylene from small dry-cleaning facilities.

    PubMed

    Chiappini, L; Delery, L; Leoz, E; Brouard, B; Fagault, Y

    2009-06-01

    Used as a solvent in the dry-cleaning industry, tetrachloroethylene (C(2)Cl(4)) can be a pollutant of residential indoor air, which can cause long-term harmful exposures because of its neurotoxicity and probable carcinogenicity. In France, dry-cleaning facilities are integrated in urban environments (shopping malls, residential buildings) and can contribute to C(2)Cl(4) exposure for customers and residents. This exploratory work presents the results from five studies carried out in one shopping mall and four residential buildings housing a dry-cleaning facility. These studies involved dry-cleaning machines fitted with a Carbon Adsorber and unfitted, with or without Air Exhaust System. Samples were collected in the cleaning facilities and in the apartments located above with passive samplers allowing measurement of time-integrated concentrations on a 7 days sampling period. It has obviously shown the degradation of indoor air quality in these environments and underlined the contributing role of the machine technology and ventilation system on the amount of released C(2)Cl(4) in the indoor air. To temper these results, it must be pointed out that some parameters (building insulation, amount of solvent used...) which would influence C(2)Cl(4) fugitive release have not been quantified and should be looked at in further studies. In France, dry-cleaning facilities are frequently integrated in urban environments (large shopping malls or residential buildings) and can significantly contribute to tetrachloroethylene (C(2)Cl(4)) population exposure. The amount of fugitive releases in these environments depends on several parameters such as the dry-cleaning machine technology (fitted or unfitted with a carbon adsorber) and the ventilation (air exhaust system). To reduce C(2)Cl(4) exposure in residential buildings and other indoor environments with on-site dry cleaners, carbon adsorber unequipped machine should be replaced by newer technology and dry cleaners should be equipped with mechanical air exhaust systems.

  6. 77 FR 13343 - Pilot Program for Early Feasibility Study Investigational Device Exemption Applications...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-03-06

    ...] Pilot Program for Early Feasibility Study Investigational Device Exemption Applications; Termination of... acceptance of nominations for the Early Feasibility Study Investigational Device Exemption (IDE) Applications... technologies to participate in a pilot program for early feasibility study IDE applications. FDA is also...

  7. Experimental study of cleaning aircraft GTE fuel injectors using a vortex ejector

    NASA Astrophysics Data System (ADS)

    Evdokimov, O. A.; Piralishvili, Sh A.; Veretennikov, S. V.; Elkes, A. A.

    2017-11-01

    The main ways of cleaning the fuel injectors and the circuits of jet and vortex ejectors used for pumping gas, liquid and two-phase media, as well as for evacuation of enclosed spaces are analyzed. The possibility of organizing the process of pumping the liquid out of the fuel injection manifold secondary circuit using a vortex ejector is shown experimentally. The regimes of manifold evacuation at various inlet liquid pressure values are studied. The technology of carbon cleaning fuel injectors using a washing liquid at various working process parameters is tested.

  8. Experimental clean combustor program, phase 2

    NASA Technical Reports Server (NTRS)

    Roberts, R.; Peduzzi, A.; Vitti, G. E.

    1976-01-01

    Combustor pollution reduction technology for commercial CTOL engines was generated and this technology was demonstrated in a full-scale JT9D engine in 1976. Component rig refinement of the two best combustor concepts were tested. These concepts are the vorbix combustor, and a hybrid combustor which combines the pilot zone of the staged premix combustor and the main zone of the swirl-can combustor. Both concepts significantly reduced all pollutant emissions relative to the JT9D-7 engine combustor. However, neither concept met all program goals. The hybrid combustor met pollution goals for unburned hydrocarbons and carbon monoxide but did not achieve the oxides of nitrogen goal. This combustor had significant performance deficiencies. The Vorbix combustor met goals for unburned hydrocarbons and oxides of nitrogen but did not achieve the carbon monoxide goal. Performance of the vorbix combustor approached the engine requirements. On the basis of these results, the vorbix combustor was selected for the engine demonstration program. A control study was conducted to establish fuel control requirements imposed by the low-emission combustor concepts and to identify conceptual control system designs. Concurrent efforts were also completed on two addendums: an alternate fuels addendum and a combustion noise addendum.

  9. Autogenic Feedback Training Exercise and pilot performance: enhanced functioning under search-and-rescue flying conditions.

    PubMed

    Cowings, P S; Kellar, M A; Folen, R A; Toscano, W B; Burge, J D

    2001-01-01

    Studies have shown that autonomous mode behavior is one cause of aircraft fatalities due to pilot error. In such cases, the pilot is in a high state of psychological and physiological arousal and tends to focus on one problem, while ignoring more critical information. This study examined the effect of training in physiological self-recognition and regulation, as a means of improving crew cockpit performance. Seventeen pilots were assigned to the treatment and control groups matched for accumulated flight hours. The treatment group contained 4 pilots from HC-130 Hercules aircraft and 4 HH-65 Dolphin helicopter pilots; the control group contained 3 pilots of HC-130s and 6 helicopter pilots. During an initial flight, physiological data were recorded on each crewmember and an instructor pilot rated individual crew performance. Eight crewmembers were then taught to regulate their own physiological response levels using Autogenic-Feedback Training Exercise (AFTE). The remaining participants received no training. During a second flight, treatment participants showed significant improvement in performance (rated by the same instructor pilot as in pretests) while controls did not improve. The results indicate that AFTE management of high states of physiological arousal may improve pilot performance during emergency flying conditions.

  10. Autogenic Feedback Training Exercise and pilot performance: enhanced functioning under search-and-rescue flying conditions

    NASA Technical Reports Server (NTRS)

    Cowings, P. S.; Kellar, M. A.; Folen, R. A.; Toscano, W. B.; Burge, J. D.

    2001-01-01

    Studies have shown that autonomous mode behavior is one cause of aircraft fatalities due to pilot error. In such cases, the pilot is in a high state of psychological and physiological arousal and tends to focus on one problem, while ignoring more critical information. This study examined the effect of training in physiological self-recognition and regulation, as a means of improving crew cockpit performance. Seventeen pilots were assigned to the treatment and control groups matched for accumulated flight hours. The treatment group contained 4 pilots from HC-130 Hercules aircraft and 4 HH-65 Dolphin helicopter pilots; the control group contained 3 pilots of HC-130s and 6 helicopter pilots. During an initial flight, physiological data were recorded on each crewmember and an instructor pilot rated individual crew performance. Eight crewmembers were then taught to regulate their own physiological response levels using Autogenic-Feedback Training Exercise (AFTE). The remaining participants received no training. During a second flight, treatment participants showed significant improvement in performance (rated by the same instructor pilot as in pretests) while controls did not improve. The results indicate that AFTE management of high states of physiological arousal may improve pilot performance during emergency flying conditions.

  11. EXPOSURE ASSESSMENT METHODS DEVELOPMENT PILOTS FOR THE NATIONAL CHILDREN'S STUDY

    EPA Science Inventory

    Accurate exposure classification tools are needed to link exposure with health effects. EPA began methods development pilot studies in 2000 to address general questions about exposures and outcome measures. Selected pilot studies are highlighted in this poster. The “Literature Re...

  12. Short term clinical efficacy of new meridol HALITOSIS tooth & tongue gel in combination with a tongue cleaner to reduce oral malodor.

    PubMed

    Wilhelm, D; Himmelmann, A; Krause, C; Wilhelm, K-P

    2013-01-01

    This study evaluated the short term efficacy of tongue cleaning with meridol HALITOSIS tooth & tongue gel in comparison to mechanical tongue cleaning alone and untreated after five and 60 minutes in patients with an oral cause of bad breath. Fifty-four male and female subjects with an intra-oral cause of halitosis (organoleptic ratings > or = 2 and volatile sulphur compounds > or = 50 ppb) participated in this crossover study and were assigned to six different treatment sequences (ABC, ACB, BAC, BCA, CAB, CBA) with no treatment (A), mechanical tongue cleaning alone (B), and tongue cleaning with tooth & tongue gel applied to the tongue cleaner (C). Efficacy was assessed by organoleptic ratings and volatile sulphur compound measurements five and 60 minutes after treatment Cleaning the tongue with tooth & tongue gel applied onto the tongue cleaner resulted in significantly reduced organoleptic ratings (p < 0.001 for the five-minute assessment; p = 0.001 for the 60-minute assessment) and volatile sulphur compounds (H2S + CH3SH: p = 0.005 for the five-minute assessment; p = 0.003 for the 60-minute assessment) compared to no treatment at the five- and 60-minute assessment time points, while mechanical tongue cleaning alone was less effective in reducing organoleptic ratings (p = 0.008 for the five-minute assessment; p = 0.144 for the 60-minute assessment) and volatile sulphur compounds (H2S + CH3SH: p = 0.261 for the five-minute assessment; p = 0.365 for the 60-minute assessment). Single tongue cleaning with meridol HALITOSIS tooth & tongue gel had a positive effect on halitosis five and 60 minutes after treatment. Tongue cleaning with tooth & tongue gel in combination with other oral hygiene procedures is a promising approach to control halitosis.

  13. The effect of ozonization on furniture dust: microbial content and immunotoxicity in vitro.

    PubMed

    Huttunen, Kati; Kauhanen, Eeva; Meklin, Teija; Vepsäläinen, Asko; Hirvonen, Maija-Riitta; Hyvärinen, Anne; Nevalainen, Aino

    2010-05-01

    Moisture and mold problems in buildings contaminate also the furniture and other movable property. If cleaning of the contaminated furniture is neglected, it may continue to cause problems to the occupants even after the moisture-damage repairs. The aim of this study was to determine the effectiveness of high-efficiency ozone treatment in cleaning of the furniture from moisture-damaged buildings. In addition, the effectiveness of two cleaning methods was compared. Samples were vacuumed from the padded areas before and after the treatment. The microbial flora and concentrations in the dust sample were determined by quantitative cultivation and QPCR-methods. The immunotoxic potential of the dust samples was analyzed by measuring effects on cell viability and production of inflammatory mediators in vitro. Concentrations of viable microbes decreased significantly in most of the samples after cleaning. Cleaning with combined steam wash and ozonisation was more effective method than ozonising alone, but the difference was not statistically significant. Detection of fungal species with PCR showed a slight but nonsignificant decrease in concentrations after the cleaning. The immunotoxic potential of the collected dust decreased significantly in most of the samples. However, in a small subgroup of samples, increased concentrations of microbes and immunotoxicological activity were detected. This study shows that a transportable cleaning unit with high-efficiency ozonising is in most cases effective in decreasing the concentrations of viable microbes and immunotoxicological activity of the furniture dust. However, the method does not destroy or remove all fungal material present in the dust, as detected with QPCR analysis, and in some cases the cleaning procedure may increase the microbial concentrations and immunotoxicity of the dust. Copyright 2010 Elsevier B.V. All rights reserved.

  14. Trial of a novel plasma gas disinfection system (Radica) to reduce mattress residual bacterial contamination in the acute hospital setting: a preliminary study.

    PubMed

    Shiely, F; Fallon, D; Casey, C; Kerins, D M; Eustace, J A

    2017-02-01

    In routine clinical practice, mattresses are manually cleaned using specialised cleaning and high-level disinfecting fluids. While effective against a wide range of organisms, the success of this approach is dependent on a thorough and complete application and is likely to be susceptible to human error and thus variable. The efficacy of available infection control measures to reduce such mattress contamination is unknown as it is not subject to quality control measures. There is a pressing need to identify more effective methods to prevent cross contamination within the medical environment, given the lack of available treatment strategies. The purpose of this study is to investigate the ability of a new technology, gaseous technology, to reduce colonization levels, compared to standard cleaning, and so attenuate superficial nosocomial infections. We conducted a prospective, single-centre, open-label, non-randomized trial with blinded outcome assessments, comparing the standard cleaning of hospital mattresses with a novel plasma based disinfection system Radica™, followed by a standard post-cleaning culturing protocol (five swabs/mattress). The median (interquartile range) maximal colony count per mattress for the 20 Radica versus 7 routinely cleaned mattresses was 1 (1-2.7) versus Too-Numerous-to-Count (TNTC) (32-TNTC), respectively, p = 0.002. Of the 20 Radica™ treated mattresses, 12 (60 %) had no positive culture result while all of the standard cleaned mattresses had at least two positive cultures. The plasma based Radica disinfection system reduces mattress bacterial colonization levels as compared to routine cleaning. This is a potentially important technology in the health care system to reduce surface colonisation and hence nosocomial infections.

  15. Electrostatic Hazard Considerations for ODC Solvent Replacement Selection Testing

    NASA Technical Reports Server (NTRS)

    Fairbourn, Brad

    1999-01-01

    ODC solvents are used to clean many critical substrates during solid rocket motor production operations. Electrostatic charge generation incidental to these cleaning operations can pose a major safety issue. Therefore, while determining the acceptability of various ODC replacement cleaners, one aspect of the selection criteria included determining the extent of electric charge generation during a typical solvent cleaning operation. A total of six candidate replacement cleaners, sixteen critical substrates, and two types of cleaning swatch materials were studied in simulated cleaning operations. Charge generation and accumulation effects were investigated by measuring the peak voltage and brush discharging effects associated with each cleaning process combination. In some cases, charge generation was found to be very severe. Using the conductivity information for each cleaner, the peak voltage data could in some cases, be qualitatively predicted. Test results indicated that severe charging effects could result in brush discharges that could potentially result in flash fire hazards when occurring in close proximity to flammable vapor/air mixtures. Process controls to effectively mitigate these hazards are discussed.

  16. Irritants and allergens at school in relation to furnishings and cleaning.

    PubMed

    Smedje, G; Norbäck, D

    2001-06-01

    In order to study the influence of furnishings and cleaning on the indoor air quality at school, 181 randomly chosen classrooms were investigated. The amounts of open shelves, textiles and other fittings were noted, data were gathered on cleaning routines, and a number of pollutants were measured in the classrooms. In classrooms with more fabrics there was more settled dust and the concentration of formaldehyde was higher. Classrooms with more open shelves had more formaldehyde, and more pet allergens in settled dust, and classrooms with a white board, instead of a chalk board, were less dusty. Classrooms mainly cleaned through wet mopping had more airborne viable bacteria but less settled dust than classrooms mainly cleaned by dry methods. In rooms where the desks and curtains were more often cleaned, the concentrations of cat and dog allergen in settled dust were lower. It is concluded that furnishings and textiles in the classroom act as significant reservoirs of irritants and allergens and have an impact on the indoor air quality at school.

  17. Validation of cleaning method for various parts fabricated at a Beryllium facility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Davis, Cynthia M.

    This study evaluated and documented a cleaning process that is used to clean parts that are fabricated at a beryllium facility at Los Alamos National Laboratory. The purpose of evaluating this cleaning process was to validate and approve it for future use to assure beryllium surface levels are below the Department of Energy’s release limits without the need to sample all parts leaving the facility. Inhaling or coming in contact with beryllium can cause an immune response that can result in an individual becoming sensitized to beryllium, which can then lead to a disease of the lungs called chronic berylliummore » disease, and possibly lung cancer. Thirty aluminum and thirty stainless steel parts were fabricated on a lathe in the beryllium facility, as well as thirty-two beryllium parts, for the purpose of testing a parts cleaning method that involved the use of ultrasonic cleaners. A cleaning method was created, documented, validated, and approved, to reduce beryllium contamination.« less

  18. IV INTERNATIONAL CONFERENCE ON ATOM AND MOLECULAR PULSED LASERS (AMPL'99): Surface oxide removal by a XeCl laser for decontamination

    NASA Astrophysics Data System (ADS)

    Sentis, M. L.; Delaporte, Ph; Marine, W.; Uteza, O.

    2000-06-01

    The laser ablation performed with an automated excimer XeCl laser unit is used for large surface cleaning. The study focuses on metal surfaces that are oxidised and are representative of contaminated surfaces with radionuclides in a context of nuclear power plant maintenance. The unit contains an XeCl laser, the beam delivery system, the particle collection cell, and the system for real-time control of cleaning processes. The interaction of laser radiation with a surface is considered, in particular, the surface damage caused by cleaning radiation. The beam delivery system consists of an optical fibre bundle of 5 m long and allows delivering 150 W at 308 nm for laser surface cleaning. The cleaning process is controlled by analysing in real time the plasma electric field evolution. The system permits the cleaning of 2 to 6 m2 h-1 of oxides with only slight substrate modifications.

  19. The Cleaning of the Parthenon West Frieze by Means of Combined IR- and UV-Radiation

    NASA Astrophysics Data System (ADS)

    Frantzikinaki, K.; Marakis, G.; Panou, A.; Vasiliadis, C.; Papakonstantinou, E.; Pouli, P.; Ditsa, T.; Zafiropulos, Vassilis; Fotakis, Costas

    This chapter deals with the cleaning of the Parthenon West Frieze by means of an innovative laser cleaning methodology. Following a comparative study of various cleaning methods, laser cleaning was proven to be the most efficient method for the removal of loose deposits and black crusts. The laser system employed is a Q-switched Nd:YAG system emitting at the fundamental and the third harmonic frequencies designed and developed by FORTH-IESL. The system emits in two wavelength beams individually or in combination. This feature, along with possible modification of the laser parameters - energy density, number of pulses, the contribution of each beam to the final combined beam - for each individual case of encrustation and substrate (marble, monochromatic layers), leads to a safe and controlled cleaning result. The project commenced in 2002 and was completed in January 2005. Since then, the Parthenon West Frieze is on display at the Acropolis Museum in Athens, Greece.

  20. Fluid drag reduction and efficient self-cleaning with rice leaf and butterfly wing bioinspired surfaces

    NASA Astrophysics Data System (ADS)

    Bixler, Gregory D.; Bhushan, Bharat

    2013-08-01

    Researchers are continually inspired by living nature to solve complex challenges. For example, unique surface characteristics of rice leaves and butterfly wings combine the shark skin (anisotropic flow leading to low drag) and lotus leaf (superhydrophobic and self-cleaning) effects, producing the so-called rice and butterfly wing effect. In this paper, we present an overview of rice leaf and butterfly wing fluid drag and self-cleaning studies. In addition, we examine two other promising aquatic surfaces in nature known for such properties, including fish scales and shark skin. Morphology, drag, self-cleaning, contact angle, and contact angle hysteresis data are presented to understand the role of wettability, viscosity, and velocity. Liquid repellent coatings are utilized to recreate or combine various effects. Discussion is provided along with conceptual models describing the role of surface structures related to low drag, self-cleaning, and antifouling properties. Modeling provides design guidance when developing novel low drag and self-cleaning surfaces for applications in the medical, marine, and industrial fields.

Top