  1. Patterning control strategies for minimum edge placement error in logic devices

    NASA Astrophysics Data System (ADS)

    Mulkens, Jan; Hanna, Michael; Slachter, Bram; Tel, Wim; Kubis, Michael; Maslow, Mark; Spence, Chris; Timoshkov, Vadim

    2017-03-01

    In this paper we discuss the edge placement error (EPE) for multi-patterning semiconductor manufacturing. In a multi-patterning scheme the creation of the final pattern is the result of a sequence of lithography and etching steps, and consequently the contour of the final pattern contains error sources of the different process steps. We describe the fidelity of the final pattern in terms of EPE, which is defined as the relative displacement of the edges of two features from their intended target position. We discuss our holistic patterning optimization approach to understand and minimize the EPE of the final pattern. As an experimental test vehicle we use the 7-nm logic device patterning process flow as developed by IMEC. This patterning process is based on Self-Aligned-Quadruple-Patterning (SAQP) using ArF lithography, combined with line cut exposures using EUV lithography. The computational metrology method to determine EPE is explained. It will be shown that ArF to EUV overlay, CDU from the individual process steps, and local CD and placement of the individual pattern features, are the important contributors. Based on the error budget, we developed an optimization strategy for each individual step and for the final pattern. Solutions include overlay and CD metrology based on angle resolved scatterometry, scanner actuator control to enable high order overlay corrections and computational lithography optimization to minimize imaging induced pattern placement errors of devices and metrology targets.

  2. Holistic approach for overlay and edge placement error to meet the 5nm technology node requirements

    NASA Astrophysics Data System (ADS)

    Mulkens, Jan; Slachter, Bram; Kubis, Michael; Tel, Wim; Hinnen, Paul; Maslow, Mark; Dillen, Harm; Ma, Eric; Chou, Kevin; Liu, Xuedong; Ren, Weiming; Hu, Xuerang; Wang, Fei; Liu, Kevin

    2018-03-01

    In this paper, we discuss the metrology methods and error budget that describe the edge placement error (EPE). EPE quantifies the pattern fidelity of a device structure made in a multi-patterning scheme. Here the pattern is the result of a sequence of lithography and etching steps, and consequently the contour of the final pattern contains error sources of the different process steps. EPE is computed by combining optical and ebeam metrology data. We show that high NA optical scatterometer can be used to densely measure in device CD and overlay errors. Large field e-beam system enables massive CD metrology which is used to characterize the local CD error. Local CD distribution needs to be characterized beyond 6 sigma, and requires high throughput e-beam system. We present in this paper the first images of a multi-beam e-beam inspection system. We discuss our holistic patterning optimization approach to understand and minimize the EPE of the final pattern. As a use case, we evaluated a 5-nm logic patterning process based on Self-Aligned-QuadruplePatterning (SAQP) using ArF lithography, combined with line cut exposures using EUV lithography.

  3. Co-optimization of lithographic and patterning processes for improved EPE performance

    NASA Astrophysics Data System (ADS)

    Maslow, Mark J.; Timoshkov, Vadim; Kiers, Ton; Jee, Tae Kwon; de Loijer, Peter; Morikita, Shinya; Demand, Marc; Metz, Andrew W.; Okada, Soichiro; Kumar, Kaushik A.; Biesemans, Serge; Yaegashi, Hidetami; Di Lorenzo, Paolo; Bekaert, Joost P.; Mao, Ming; Beral, Christophe; Larivière, Stephane

    2017-03-01

    Complimentary lithography is already being used for advanced logic patterns. The tight pitches for 1D Metal layers are expected to be created using spacer based multiple patterning ArF-i exposures and the more complex cut/block patterns are made using EUV exposures. At the same time, control requirements of CDU, pattern shift and pitch-walk are approaching sub-nanometer levels to meet edge placement error (EPE) requirements. Local variability, such as Line Edge Roughness (LER), Local CDU, and Local Placement Error (LPE), are dominant factors in the total Edge Placement error budget. In the lithography process, improving the imaging contrast when printing the core pattern has been shown to improve the local variability. In the etch process, it has been shown that the fusion of atomic level etching and deposition can also improve these local variations. Co-optimization of lithography and etch processing is expected to further improve the performance over individual optimizations alone. To meet the scaling requirements and keep process complexity to a minimum, EUV is increasingly seen as the platform for delivering the exposures for both the grating and the cut/block patterns beyond N7. In this work, we evaluated the overlay and pattern fidelity of an EUV block printed in a negative tone resist on an ArF-i SAQP grating. High-order Overlay modeling and corrections during the exposure can reduce overlay error after development, a significant component of the total EPE. During etch, additional degrees of freedom are available to improve the pattern placement error in single layer processes. Process control of advanced pitch nanoscale-multi-patterning techniques as described above is exceedingly complicated in a high volume manufacturing environment. Incorporating potential patterning optimizations into both design and HVM controls for the lithography process is expected to bring a combined benefit over individual optimizations. In this work we will show the EPE performance improvement for a 32nm pitch SAQP + block patterned Metal 2 layer by cooptimizing the lithography and etch processes. Recommendations for further improvements and alternative processes will be given.

  4. EUV local CDU healing performance and modeling capability towards 5nm node

    NASA Astrophysics Data System (ADS)

    Jee, Tae Kwon; Timoshkov, Vadim; Choi, Peter; Rio, David; Tsai, Yu-Cheng; Yaegashi, Hidetami; Koike, Kyohei; Fonseca, Carlos; Schoofs, Stijn

    2017-10-01

    Both local variability and optical proximity correction (OPC) errors are big contributors to the edge placement error (EPE) budget which is closely related to the device yield. The post-litho contact hole healing will be demonstrated to meet after-etch local variability specifications using a low dose, 30mJ/cm2 dose-to-size, positive tone developed (PTD) resist with relevant throughput in high volume manufacturing (HVM). The total local variability of the node 5nm (N5) contact holes will be characterized in terms of local CD uniformity (LCDU), local placement error (LPE), and contact edge roughness (CER) using a statistical methodology. The CD healing process has complex etch proximity effects, so the OPC prediction accuracy is challenging to meet EPE requirements for the N5. Thus, the prediction accuracy of an after-etch model will be investigated and discussed using ASML Tachyon OPC model.

  5. EPE fundamentals and impact of EUV: Will traditional design-rule calculations work in the era of EUV?

    NASA Astrophysics Data System (ADS)

    Gabor, Allen H.; Brendler, Andrew C.; Brunner, Timothy A.; Chen, Xuemei; Culp, James A.; Levinson, Harry J.

    2018-03-01

    The relationship between edge placement error, semiconductor design-rule determination and predicted yield in the era of EUV lithography is examined. This paper starts with the basics of edge placement error and then builds up to design-rule calculations. We show that edge placement error (EPE) definitions can be used as the building blocks for design-rule equations but that in the last several years the term "EPE" has been used in the literature to refer to many patterning errors that are not EPE. We then explore the concept of "Good Fields"1 and use it predict the n-sigma value needed for design-rule determination. Specifically, fundamental yield calculations based on the failure opportunities per chip are used to determine at what n-sigma "value" design-rules need to be tested to ensure high yield. The "value" can be a space between two features, an intersect area between two features, a minimum area of a feature, etc. It is shown that across chip variation of design-rule important values needs to be tested at sigma values between seven and eight which is much higher than the four-sigma values traditionally used for design-rule determination. After recommending new statistics be used for design-rule calculations the paper examines the impact of EUV lithography on sources of variation important for design-rule calculations. We show that stochastics can be treated as an effective dose variation that is fully sampled across every chip. Combining the increased within chip variation from EUV with the understanding that across chip variation of design-rule important values needs to not cause a yield loss at significantly higher sigma values than have traditionally been looked at, the conclusion is reached that across-wafer, wafer-to-wafer and lot-to-lot variation will have to overscale for any technology introducing EUV lithography where stochastic noise is a significant fraction of the effective dose variation. We will emphasize stochastic effects on edge placement error distributions and appropriate design-rule setting. While CD distributions with long tails coming from stochastic effects do bring increased risk of failure (especially on chips that may have over a billion failure opportunities per layer) there are other sources of variation that have sharp cutoffs, i.e. have no tails. We will review these sources and show how distributions with different skew and kurtosis values combine.

  6. Monte Carlo simulation of edge placement error

    NASA Astrophysics Data System (ADS)

    Kobayashi, Shinji; Okada, Soichiro; Shimura, Satoru; Nafus, Kathleen; Fonseca, Carlos; Estrella, Joel; Enomoto, Masashi

    2018-03-01

    In the discussion of edge placement error (EPE), we proposed interactive pattern fidelity error (IPFE) as an indicator to judge pass/fail of integrated patterns. IPFE consists of lower and upper layer EPEs (CD and center of gravity: COG) and overlay, which is decided from the combination of each maximum variation. We succeeded in obtaining the IPFE density function by Monte Carlo simulation. In the results, we also found that the standard deviation (σ) of each indicator should be controlled by 4.0σ, at the semiconductor grade, such as 100 billion patterns per die. Moreover, CD, COG and overlay were analyzed by analysis of variance (ANOVA); we can discuss all variations from wafer to wafer (WTW), pattern to pattern (PTP), line edge roughness (LWR) and stochastic pattern noise (SPN) on an equal footing. From the analysis results, we can determine that these variations belong to which process and tools. Furthermore, measurement length of LWR is also discussed in ANOVA. We propose that the measurement length for IPFE analysis should not be decided to the micro meter order, such as >2 μm length, but for which device is actually desired.

  7. Impact of materials engineering on edge placement error (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Freed, Regina; Mitra, Uday; Zhang, Ying

    2017-04-01

    Transistor scaling has transitioned from wavelength scaling to multi-patterning techniques, due to the resolution limits of immersion of immersion lithography. Deposition and etch have enabled scaling in the by means of SADP and SAQP. Spacer based patterning enables extremely small linewidths, sufficient for several future generations of transistors. However, aligning layers in Z-direction, as well as aligning cut and via patterning layers, is becoming a road-block due to global and local feature variation and fidelity. This presentation will highlight the impact of deposition and etch on this feature alignment (EPE) and illustrate potential paths toward lowering EPE using material engineering.

  8. Advanced CD-SEM solution for edge placement error characterization of BEOL pitch 32nm metal layers

    NASA Astrophysics Data System (ADS)

    Charley, A.; Leray, P.; Lorusso, G.; Sutani, T.; Takemasa, Y.

    2018-03-01

    Metrology plays an important role in edge placement error (EPE) budgeting. Control for multi-patterning applications as new critical distances needs to be measured (edge to edge) and requirements become tighter and tighter in terms of accuracy and precision. In this paper we focus on imec iN7 BEOL platform and particularly on M2 patterning scheme using SAQP + block EUV for a 7.5 track logic design. Being able to characterize block to SAQP edge misplacement is important in a budgeting exercise (1) but is also extremely difficult due to challenging edge detection with CD-SEM (similar materials, thin layers, short distances, 3D features). In this study we develop an advanced solution to measure block to SAQP placement, we characterize it in terms of sensitivity, precision and accuracy through the comparison to reference metrology. In a second phase, the methodology is applied to budget local effects and the results are compared to the characterization of the SAQP and block independently.

  9. Boundary-based cellwise OPC for standard-cell layouts

    NASA Astrophysics Data System (ADS)

    Pawlowski, David M.; Deng, Liang; Wong, Martin D. F.

    2007-03-01

    Model based optical proximity correction (OPC) has become necessary at 90nm technology node. Cellwise OPC is an attractive technique to reduce the mask data size as well as the prohibitive runtime of full-chip OPC. As feature dimensions have gotten smaller, the radius of influence for edge features has extended further into neighboring cells such that it is no longer sufficient to perform cellwise OPC independent of neighboring cells, especially for the critical layers. The methodology described in this work accounts for features in neighboring cells and allows a cellwise approach to be applied to cells with a printed gate length of 45nm with the projection that it can also be applied to future technology nodes. OPC-ready cells are generated at library creation (independent of placement) using a boundary-based technique. Each cell has a tractable number of OPC-ready versions due to an intelligent characterization of standard cell layout features. Results are very promising: the average edge placement error (EPE) for all metal1 features in 100 layouts is 0.731nm which is less than 1% of metal1 width; the maximum EPE for poly features reduced to 1/3, compared to cellwise OPC without considering boundaries, creating similar levels of lithographic accuracy while obviating any of the drawbacks inherent in layout specific full-chip model-based OPC.

  10. An optimized OPC and MDP flow for reducing mask write time and mask cost

    NASA Astrophysics Data System (ADS)

    Yang, Ellyn; Li, Cheng He; Park, Se Jin; Zhu, Yu; Guo, Eric

    2010-09-01

    In the process of optical proximity correction, layout edge or fragment is migrating to proper position in order to minimize edge placement error (EPE). During this fragment migration, several factors other than EPE can be also taken into account as a part of cost function for optimal fragment displacement. Several factors are devised in favor of OPC stability, which can accommodate room for high mask error enhancement factor (MEEF), lack of process window, catastrophic pattern failure such as pinch/bridge and improper fragmentation. As technology node becomes finer, there happens conflict between OPC accuracy and stability. Especially for metal layers, OPC has focused on the stability by loss of accurate OPC results. On this purpose, several techniques have been introduced, which are target smoothing, process window aware OPC, model-based retargeting and adaptive OPC. By utilizing those techniques, OPC enables more stabilized patterning, instead of realizing design target exactly on wafer. Inevitably, post-OPC layouts become more complicated because those techniques invoke additional edge, or fragments prior to correction or during OPC iteration. As a result, jogs of post OPC layer can be dramatically increased, which results in huge number of shot count after data fracturing. In other words, there is trade-off relationship between data complexity and various methods for OPC stability. In this paper, those relationships have been investigated with respect to several technology nodes. The mask shot count reduction is achieved by reducing the number of jogs with which EPE difference are within pre-specified value. The effect of jog smoothing on OPC output - in view of OPC performance and mask data preparation - was studied quantitatively for respective technology nodes.

  11. Two-layer critical dimensions and overlay process window characterization and improvement in full-chip computational lithography

    NASA Astrophysics Data System (ADS)

    Sturtevant, John L.; Liubich, Vlad; Gupta, Rachit

    2016-04-01

    Edge placement error (EPE) was a term initially introduced to describe the difference between predicted pattern contour edge and the design target for a single design layer. Strictly speaking, this quantity is not directly measurable in the fab. What is of vital importance is the relative edge placement errors between different design layers, and in the era of multipatterning, the different constituent mask sublayers for a single design layer. The critical dimensions (CD) and overlay between two layers can be measured in the fab, and there has always been a strong emphasis on control of overlay between design layers. The progress in this realm has been remarkable, accelerated in part at least by the proliferation of multipatterning, which reduces the available overlay budget by introducing a coupling of overlay and CD errors for the target layer. Computational lithography makes possible the full-chip assessment of two-layer edge to edge distances and two-layer contact overlap area. We will investigate examples of via-metal model-based analysis of CD and overlay errors. We will investigate both single patterning and double patterning. For single patterning, we show the advantage of contour-to-contour simulation over contour to target simulation, and how the addition of aberrations in the optical models can provide a more realistic CD-overlay process window (PW) for edge placement errors. For double patterning, the interaction of 4-layer CD and overlay errors is very complex, but we illustrate that not only can full-chip verification identify potential two-layer hotspots, the optical proximity correction engine can act to mitigate such hotspots and enlarge the joint CD-overlay PW.

  12. Ultimate patterning limits for EUV at 5nm node and beyond

    NASA Astrophysics Data System (ADS)

    Ali, Rehab Kotb; Hamed Fatehy, Ahmed; Lafferty, Neal; Word, James

    2018-03-01

    The 5nm technology node introduces more aggressive geometries than previous nodes. In this paper, we are introducing a comprehensive study to examine the pattering limits of EUV at 0.33NA. The study is divided into two main approaches: (A) Exploring pattering limits of Single Exposure EUV Cut/Block mask in Self-Aligned-Multi-Patterning (SAMP) process, and (B) Exploring the pattering limits of a Single Exposure EUV printing of metal Layers. The printability of the resulted OPC masks is checked through a model based manufacturing flow for the two pattering approaches. The final manufactured patterns are quantified by Edge Placement Error (EPE), Process Variation Band (PVBand), soft/hard bridging and pinching, Image Log Slope (ILS) and Common Depth of Focus (CDOF)

  13. Edge placement error control and Mask3D effects in High-NA anamorphic EUV lithography

    NASA Astrophysics Data System (ADS)

    van Setten, Eelco; Bottiglieri, Gerardo; de Winter, Laurens; McNamara, John; Rusu, Paul; Lubkoll, Jan; Rispens, Gijsbert; van Schoot, Jan; Neumann, Jens Timo; Roesch, Matthias; Kneer, Bernhard

    2017-10-01

    To enable cost-effective shrink at the 3nm node and beyond, and to extend Moore's law into the next decade, ASML is developing a new high-NA EUV platform. The high-NA system is targeted to feature a numerical aperture (NA) of 0.55 to extend the single exposure resolution limit to 8nm half pitch. The system is being designed to achieve an on-product-overlay (OPO) performance well below 2nm, a high image contrast to drive down local CD errors and to obtain global CDU at sub-1nm level to be able to meet customer edge placement error (EPE) requirements for the devices of the future. EUV scanners employ reflective Bragg multi-layer mirrors in the mask and in the Projection Optics Box (POB) that is used to project the mask pattern into the photoresist on the silicon wafer. These MoSi multi-layer mirrors are tuned for maximum reflectivity, and thus productivity, at 13.5nm wavelength. The angular range of incident light for which a high reflectivity at the reticle can be obtained is limited to +/- 11o, exceeding the maximum angle occurring in current 0.33NA scanners at 4x demagnification. At 0.55NA the maximum angle at reticle level would extend up to 17o in the critical (scanning) direction and compromise the imaging performance of horizontal features severely. To circumvent this issue a novel anamorphic optics design has been introduced, which has a 4x demagnification in the X- (slit) direction and 8x demagnification in the Y- (scanning) direction as well as a central obscuration in the exit pupil. In this work we will show that the EUV high-NA anamorphic concept can successfully solve the angular reflectivity issues and provide good imaging performance in both directions. Several unique imaging challenges in comparison to the 0.33NA isomorphic baseline are being studied, such as the impact of the central obscuration in the POB and Mask-3D effects at increased NA that seem most pronounced for vertical features. These include M3D induced contrast loss and non-telecentricity. We will explore the solutions needed to mitigate these effects and to offer high quality imaging to be able to meet the required EPE performance in both orientations.

  14. Design and pitch scaling for affordable node transition and EUV insertion scenario

    NASA Astrophysics Data System (ADS)

    Kim, Ryoung-han; Ryckaert, Julien; Raghavan, Praveen; Sherazi, Yasser; Debacker, Peter; Trivkovic, Darko; Gillijns, Werner; Tan, Ling Ee; Drissi, Youssef; Blanco, Victor; Bekaert, Joost; Mao, Ming; Larivière, Stephane; McIntyre, Greg

    2017-04-01

    imec's DTCO and EUV achievement toward imec 7nm (iN7) technology node which is industry 5nm node equivalent is reported with a focus on cost and scaling. Patterning-aware design methodology supports both iArF multiple patterning and EUV under one compliant design rule. FinFET device with contacted poly pitch of 42nm and metal pitch of 32nm with 7.5-track, 6.5-track, and 6-track standard cell library are explored. Scaling boosters are used to provide additional scaling and die cost benefit while lessening pitch shrink burden, and it makes EUV insertion more affordable. EUV pattern fidelity is optimized through OPC, SMO, M3D, mask sizing and SRAF. Processed wafers were characterized and edge-placement-error (EPE) variability is validated for EUV insertion. Scale-ability and cost of ownership of EUV patterning in aligned with iN7 standard cell design, integration and patterning specification are discussed.

  15. Considerations for pattern placement error correction toward 5nm node

    NASA Astrophysics Data System (ADS)

    Yaegashi, Hidetami; Oyama, Kenichi; Hara, Arisa; Natori, Sakurako; Yamauchi, Shohei; Yamato, Masatoshi; Koike, Kyohei; Maslow, Mark John; Timoshkov, Vadim; Kiers, Ton; Di Lorenzo, Paolo; Fonseca, Carlos

    2017-03-01

    Multi-patterning has been adopted widely in high volume manufacturing as 193 immersion extension, and it becomes realistic solution of nano-order scaling. In fact, it must be key technology on single directional (1D) layout design [1] for logic devise and it becomes a major option for further scaling technique in SAQP. The requirement for patterning fidelity control is getting savior more and more, stochastic fluctuation as well as LER (Line edge roughness) has to be micro-scopic observation aria. In our previous work, such atomic order controllability was viable in complemented technique with etching and deposition [2]. Overlay issue form major potion in yield management, therefore, entire solution is needed keenly including alignment accuracy on scanner and detectability on overlay measurement instruments. As EPE (Edge placement error) was defined as the gap between design pattern and contouring of actual pattern edge, pattern registration in single process level must be considerable. The complementary patterning to fabricate 1D layout actually mitigates any process restrictions, however, multiple process step, symbolized as LELE with 193-i, is burden to yield management and affordability. Recent progress of EUV technology is remarkable, and it is major potential solution for such complicated technical issues. EUV has robust resolution limit and it must be definitely strong scaling driver for process simplification. On the other hand, its stochastic variation such like shot noise due to light source power must be resolved with any additional complemented technique. In this work, we examined the nano-order CD and profile control on EUV resist pattern and would introduce excellent accomplishments.

  16. Unbiased roughness measurements: the key to better etch performance

    NASA Astrophysics Data System (ADS)

    Liang, Andrew; Mack, Chris; Sirard, Stephen; Liang, Chen-wei; Yang, Liu; Jiang, Justin; Shamma, Nader; Wise, Rich; Yu, Jengyi; Hymes, Diane

    2018-03-01

    Edge placement error (EPE) has become an increasingly critical metric to enable Moore's Law scaling. Stochastic variations, as characterized for lines by line width roughness (LWR) and line edge roughness (LER), are dominant factors in EPE and known to increase with the introduction of EUV lithography. However, despite recommendations from ITRS, NIST, and SEMI standards, the industry has not agreed upon a methodology to quantify these properties. Thus, differing methodologies applied to the same image often result in different roughness measurements and conclusions. To standardize LWR and LER measurements, Fractilia has developed an unbiased measurement that uses a raw unfiltered line scan to subtract out image noise and distortions. By using Fractilia's inverse linescan model (FILM) to guide development, we will highlight the key influences of roughness metrology on plasma-based resist smoothing processes. Test wafers were deposited to represent a 5 nm node EUV logic stack. The patterning stack consists of a core Si target layer with spin-on carbon (SOC) as the hardmask and spin-on glass (SOG) as the cap. Next, these wafers were exposed through an ASML NXE 3350B EUV scanner with an advanced chemically amplified resist (CAR). Afterwards, these wafers were etched through a variety of plasma-based resist smoothing techniques using a Lam Kiyo conductor etch system. Dense line and space patterns on the etched samples were imaged through advanced Hitachi CDSEMs and the LER and LWR were measured through both Fractilia and an industry standard roughness measurement software. By employing Fractilia to guide plasma-based etch development, we demonstrate that Fractilia produces accurate roughness measurements on resist in contrast to an industry standard measurement software. These results highlight the importance of subtracting out SEM image noise to obtain quicker developmental cycle times and lower target layer roughness.

  17. Pattern uniformity control in integrated structures

    NASA Astrophysics Data System (ADS)

    Kobayashi, Shinji; Okada, Soichiro; Shimura, Satoru; Nafus, Kathleen; Fonseca, Carlos; Biesemans, Serge; Enomoto, Masashi

    2017-03-01

    In our previous paper dealing with multi-patterning, we proposed a new indicator to quantify the quality of final wafer pattern transfer, called interactive pattern fidelity error (IPFE). It detects patterning failures resulting from any source of variation in creating integrated patterns. IPFE is a function of overlay and edge placement error (EPE) of all layers comprising the final pattern (i.e. lower and upper layers). In this paper, we extend the use cases with Via in additional to the bridge case (Block on Spacer). We propose an IPFE budget and CD budget using simple geometric and statistical models with analysis of a variance (ANOVA). In addition, we validate the model with experimental data. From the experimental results, improvements in overlay, local-CDU (LCDU) of contact hole (CH) or pillar patterns (especially, stochastic pattern noise (SPN)) and pitch walking are all critical to meet budget requirements. We also provide a special note about the importance of the line length used in analyzing LWR. We find that IPFE and CD budget requirements are consistent to the table of the ITRS's technical requirement. Therefore the IPFE concept can be adopted for a variety of integrated structures comprising digital logic circuits. Finally, we suggest how to use IPFE for yield management and optimization requirements for each process.

  18. Model-based MPC enables curvilinear ILT using either VSB or multi-beam mask writers

    NASA Astrophysics Data System (ADS)

    Pang, Linyong; Takatsukasa, Yutetsu; Hara, Daisuke; Pomerantsev, Michael; Su, Bo; Fujimura, Aki

    2017-07-01

    Inverse Lithography Technology (ILT) is becoming the choice for Optical Proximity Correction (OPC) of advanced technology nodes in IC design and production. Multi-beam mask writers promise significant mask writing time reduction for complex ILT style masks. Before multi-beam mask writers become the main stream working tools in mask production, VSB writers will continue to be the tool of choice to write both curvilinear ILT and Manhattanized ILT masks. To enable VSB mask writers for complex ILT style masks, model-based mask process correction (MB-MPC) is required to do the following: 1). Make reasonable corrections for complex edges for those features that exhibit relatively large deviations from both curvilinear ILT and Manhattanized ILT designs. 2). Control and manage both Edge Placement Errors (EPE) and shot count. 3. Assist in easing the migration to future multi-beam mask writer and serve as an effective backup solution during the transition. In this paper, a solution meeting all those requirements, MB-MPC with GPU acceleration, will be presented. One model calibration per process allows accurate correction regardless of the target mask writer.

  19. Eosinophilic pleural effusion: incidence, etiology and prognostic significance.

    PubMed

    Ferreiro, Lucía; San José, Esther; González-Barcala, Francisco Javier; Alvarez-Dobaño, José Manuel; Golpe, Antonio; Gude, Francisco; Anchorena, Christian; Pereyra, Marco F; Zamarrón, Carlos; Valdés, Luis

    2011-10-01

    Eosinophilic pleural effusion (EPE) has been associated with less risk for malignancy with a potential causal relationship with the presence of air and/or blood in the pleural space. However, these theories have fallen by the wayside in the light of recent publications. To determine the incidence and etiology of EPE and to observe whether the eosinophils in the pleural liquid (PL) increase in successive thoracocenteses. We analyzed 730 PL samples from 605 patients hospitalized between January 2004 and December 2010. We identified 55 samples with EPE from 50 patients (8.3%). The most frequent etiologies of EPE were: unknown (36%) and neoplasm (30%). There were no significant differences in the incidence of neoplasms between the non-eosinophilic pleural effusions (non-EPE) (25.9%) and the EPE (30%) (p=0.533). One hundred patients (16.5%) underwent a second thoracocentesis. Out of the 9 who had EPE in the first, 6 maintained EPE in the second. Out of the 91 with non-EPE in the first thoracocentesis, 8 (8.8%) had EPE in the repeat thoracocentesis. The percentage of eosinophils did not increase in the successive thoracocenteses (p=0.427). In the EPE, a significant correlation was found between the number of hematites and eosinophils in the PL (r=0.563; p=0.000). An EPE cannot be considered an indicator of benignancy, therefore it should be studied as any other pleural effusion. The number of eosinophils does not seem to increase with the of repetition of thoracocentesis and, lastly, the presence of blood in the PL could explain the existence of EPE. Copyright © 2011 SEPAR. Published by Elsevier Espana. All rights reserved.

  20. Self-aligned quadruple patterning using spacer on spacer integration optimization for N5

    NASA Astrophysics Data System (ADS)

    Thibaut, Sophie; Raley, Angélique; Mohanty, Nihar; Kal, Subhadeep; Liu, Eric; Ko, Akiteru; O'Meara, David; Tapily, Kandabara; Biolsi, Peter

    2017-04-01

    To meet scaling requirements, the semiconductor industry has extended 193nm immersion lithography beyond its minimum pitch limitation using multiple patterning schemes such as self-aligned double patterning, self-aligned quadruple patterning and litho-etch / litho etch iterations. Those techniques have been declined in numerous options in the last few years. Spacer on spacer pitch splitting integration has been proven to show multiple advantages compared to conventional pitch splitting approach. Reducing the number of pattern transfer steps associated with sacrificial layers resulted in significant decrease of cost and an overall simplification of the double pitch split technique. While demonstrating attractive aspects, SAQP spacer on spacer flow brings challenges of its own. Namely, material set selections and etch chemistry development for adequate selectivities, mandrel shape and spacer shape engineering to improve edge placement error (EPE). In this paper we follow up and extend upon our previous learning and proceed into more details on the robustness of the integration in regards to final pattern transfer and full wafer critical dimension uniformity. Furthermore, since the number of intermediate steps is reduced, one will expect improved uniformity and pitch walking control. This assertion will be verified through a thorough pitch walking analysis.

  1. Community carriage of ESBL-producing Escherichia coli is associated with strains of low pathogenicity: a Swedish nationwide study.

    PubMed

    Ny, Sofia; Löfmark, Sonja; Börjesson, Stefan; Englund, Stina; Ringman, Maj; Bergström, Jakob; Nauclér, Pontus; Giske, Christian G; Byfors, Sara

    2017-02-01

    Community carriage of ESBL-producing Escherichia coli (EPE) is common worldwide and there is a need to understand the connection between carriage and infection. We compared the molecular characteristics of EPE among Swedish community carriers with those of EPE causing invasive infections. We collected 2134 faecal samples from randomly selected Swedish inhabitants and examined them for the presence of EPE. All participating volunteers answered a questionnaire about putative risk factors for EPE carriage. Suspected EPE isolates (n = 418) from patients with bloodstream infection (BSI) were collected from Swedish laboratories. Isolates were genotypically and phenotypically characterized. Our results show that the EPE population found in carriers generally had lower pathogenicity compared with the isolates from BSIs, since carriers had a lower proportion of E. coli belonging to phylogroup B2, ST131 and ST131 subclone H30-Rx. Isolates from carriers also had lower levels of multiresistance. The Swedish carriage rate of EPE was 4.7% (101/2134) among healthy volunteers. Risk factors associated with carriage were travel to countries in Asia (OR = 3.6, 95% CI = 1.4-9.2) and Africa (OR = 3.6, 95% CI = 1.7-7.7) and a diet without pork (OR = 0.5, 95% CI = 0.3-0.8 for pork eaters). E. coli host factors previously associated with higher pathogenicity were all more common in BSIs compared with carriers. This indicates that the risk of invasive infection with EPE may be relatively modest in many community carriers and that EPE carriage of high-risk strains should be the focus of attention for prevention. © The Author 2016. Published by Oxford University Press on behalf of the British Society for Antimicrobial Chemotherapy.

  2. Pharmacological and toxicological study of a chemical-standardized ethanol extract of the branches and leaves from Eysenhardtia polystachya (Ortega) Sarg. (Fabaceae).

    PubMed

    Alonso-Castro, Angel Josabad; Zapata-Morales, Juan Ramón; Arana-Argáez, Victor; Torres-Romero, Julio Cesar; Ramírez-Villanueva, Eyra; Pérez-Medina, Sabino Eduardo; Ramírez-Morales, Marco Antonio; Juárez-Méndez, Mario Alberto; Infante-Barrios, Yessica Paola; Martínez-Gutiérrez, Fidel; Carranza-Álvarez, Candy; Isiordia-Espinoza, Mario Alberto; Flores-Santos, Andrés

    2018-06-18

    Eysenhardtia polystachya is used for the empirical treatment of cancer, infections, diarrhea, inflammation, and pain. This study identified, using GC-MS, the main chemical components in an ethanol extract of E. polystachya branches and leaves (EPE) and tested its cytotoxic, antimicrobial, anti-diarrheal, anti-inflammatory, and antinociceptive effects. The in vitro and in vivo toxicity of EPE was evaluated using the comet assay in human peripheral blood mononuclear cells (PBMC) and the acute toxicity test in mice, respectively. The cytotoxic and the antimicrobial effects were performed using the MTT assay and the minimum inhibitory concentration (MIC) test, respectively. The levels of pro-inflammatory mediators in LPS-stimulated macrophages were measured to evaluate the in vitro anti-inflammatory effects of EPE. The antidiarrheal (castor oil test, small intestine transit, and castor oil-induced enteropooling), and anti-inflammatory activities (TPA and carrageenan) of EPE were also performed. The antinociceptive actions of EPE were carried out with the following tests: acetic acid, formalin, and hot plate. The hypnotic and locomotor effects were analyzed using pentobarbital and a rotarod system, respectively. The main component in EPE was D-pinitol (26.93%). The antidiarrheal and antinociceptive effects of D-pinitol were also evaluated. EPE showed low in vitro toxicity (DNA damage in PBMC at concentrations higher than 200 µg/ml), and low in vivo toxicity (LD 50 > 2000 mg/kg i.p. and p.o.). Furthermore, EPE lacked cytotoxic activity (IC 50 > 300 µg/ml) on human cancer cells, but showed good antimicrobial effects in E. coli (MIC=1.56 µg/ml) and S. aureus (MIC = 0.78 µg/ml). In multi-drug resistant microorganisms, EPE showed MIC> 100 µg/ml. EPE exerted in vitro anti-inflammatory effects, mainly, by the decrease in the production of H 2 O 2 (IC 50 = 43.9 ± 3.8 µg/ml), and IL-6 (73.3 ± 6.9 µg/ml). EPE (ED 50 =7.5 ± 0.9 mg/kg) and D-pinitol (ED 50 = 0.1 ± 0.03 mg/kg) showed antidiarrheal activity, and antinociceptive effects in the acetic acid test with ED 50 = 117 ± 14.5 mg/kg for EPE and 33 ± 3.2 mg/kg for D-pinitol. EPE showed also antinociceptive activity in the phase 2 of the formalin test (ED 50 = 48.9 ± 3.9 mg/kg), without inducing hypnotic effects or altering the locomotor activity in mice. The results here presented corroborate the folk medicinal use of Eysenhardtia polystachya in the treatment of infections, diarrhea, inflammation, and pain. D-pinitol, the main metabolite of EPE, showed antinociceptive and antidiarrheal effects with similar potency compared to standard drugs. Copyright © 2018 Elsevier B.V. All rights reserved.

  3. Differential Relations of Depression and Social Anxiety Symptoms to the Facets of Extraversion/Positive Emotionality

    PubMed Central

    Naragon-Gainey, Kristin; Watson, David; Markon, Kristian E.

    2009-01-01

    Previous research has shown that depression and social anxiety—two “facets” of internalizing psychopathology— both are characterized by low levels of extraversion/positive emotionality (E/PE). However, little is known about the relations of the facets of E/PE with symptoms of depression and social anxiety. This study utilized multiple measures of each facet of E/PE, as well as depression and social anxiety symptoms. Self-report data were collected from large samples of college students and psychiatric outpatients. Separate factor analyses in each sample revealed a four-factor structure of E/PE, consisting of Sociability, Positive Emotionality, Ascendance, and Fun-Seeking. Structural equation modeling revealed that, after controlling for the higher-order internalizing factor and the overlap among the E/PE facets, social anxiety was broadly related to all four facets of E/PE, whereas depression was strongly related only to low positive emotionality. Implications for hierarchical models of personality and psychopathology, assessment and treatment, and etiological models are discussed. PMID:19413405

  4. Education and public engagement in observatory operations

    NASA Astrophysics Data System (ADS)

    Gabor, Pavel; Mayo, Louis; Zaritsky, Dennis

    2016-07-01

    Education and public engagement (EPE) is an essential part of astronomy's mission. New technologies, remote observing and robotic facilities are opening new possibilities for EPE. A number of projects (e.g., Telescopes In Education, MicroObservatory, Goldstone Apple Valley Radio Telescope and UNC's Skynet) have developed new infrastructure, a number of observatories (e.g., University of Arizona's "full-engagement initiative" towards its astronomy majors, Vatican Observatory's collaboration with high-schools) have dedicated their resources to practical instruction and EPE. Some of the facilities are purpose built, others are legacy telescopes upgraded for remote or automated observing. Networking among institutions is most beneficial for EPE, and its implementation ranges from informal agreements between colleagues to advanced software packages with web interfaces. The deliverables range from reduced data to time and hands-on instruction while operating a telescope. EPE represents a set of tasks and challenges which is distinct from research applications of the new astronomical facilities and operation modes. In this paper we examine the experience with several EPE projects, and some lessons and challenges for observatory operation.

  5. EPE The Extreme Physics Explorer

    NASA Technical Reports Server (NTRS)

    Garcia, Michael; Elvis, Martin; Bookbinder, Jay; Brenneman, Laura; Bulbul, Esra; Nulsen, Paul; Patnaude, Dan; Smith, Randall; Bandler, Simon; Okajima, Takashi; hide

    2012-01-01

    The Extreme Physics Explorer (EPE) is a mission concept that will address fundamental and timely questions in astrophysics which are primary science objectives of IXO. The reach of EPE to the areas outlined in NASA RFI NNH11ZDA018L is shown as a table. The dark green indicates areas in which EPE can do the basic IXO science, and the light green areas where EPE can contribute but will not reach the full IXO capability. To address these science questions, EPE will trace orbits close to the event horizon of black holes, measure black hole spin in active galactic nuclei (AGN), use spectroscopy to characterize outflows and the environment of AGN, map bulk motions and turbulence in galaxy clusters, and observe the process of cosmic feedback where black holes inject energy on galactic and intergalactic scales. EPE gives up the high resolution imaging of IXO in return for lightweight, high TRL foil mirrors which will provide >20 times the effective area of ASTRO-H and similar spatial resolution, with a beam sufficient to study point sources and nearby galaxies and clusters. Advances in micro-calorimeters allow improved performance at high rates with twice the energy resolution of ASTRO-H. A lower TRL option would provide 200 times the area of ASTRO-H using a micro-channel plate optic (MCPO) and a deployable optical bench. Both options are in the middle range of RFI missions at between $600M and $1000M. The EPE foil optic has direct heritage to ASTRO-H, allowing robust cost estimates. The spacecraft is entirely off the shelf and introduces no difficult requirements. The mission could be started and launched in this decade to an L2 orbit, with a three-year lifetime and consumables for 5 years. While ASTRO-H will give us the first taste of high-resolution, non-dispersive X-ray spectroscopy, it will be limited to small numbers of objects in many categories. EPE will give us the first statistically significant samples in each of these categories.

  6. Species-specificity of equine and porcine Lawsonia intracellularis isolates in laboratory animals

    PubMed Central

    Sampieri, Francesca; Vannucci, Fabio A.; Allen, Andrew L.; Pusterla, Nicola; Antonopoulos, Aphroditi J.; Ball, Katherine R.; Thompson, Julie; Dowling, Patricia M.; Hamilton, Don L.; Gebhart, Connie J.

    2013-01-01

    Lawsonia intracellularis infection causes proliferative enteropathy (PE) in many mammalian species, with porcine and equine proliferative enteropathy (PPE and EPE) known worldwide. Hamsters are a well-published animal model for PPE infection studies in pigs. There is no laboratory animal model for EPE infection studies and it is not known whether there is species-specificity for equine or porcine isolates of L. intracellularis in animal models. The objective of this study was to determine whether it is possible to generate typical EPE lesions in hamsters after inoculation with an equine strain of L. intracellularis (EPE strain) and whether it is comparatively possible to generate PPE lesions in rabbits after inoculation with a porcine strain of L. intracellularis (PPE strain). In 2 separate trials, 4-week-old and 3-week-old weanling golden Syrian hamsters were challenged with EPE strains and compared to uninfected (both trials) and PPE-infected controls (Trial 2 only). Concurrently, 6 female New Zealand white juvenile rabbits were infected with PPE strain and observed concomitantly to 8 similar rabbits infected with EPE strain for a different experiment. Hamsters and rabbits were observed for 21 to 24 days post-infection (DPI), depending on the experiment. Neither infected species developed clinical signs. The presence of disease was assessed with diagnostic techniques classically used for pigs and horses: immune-peroxidase monolayer assay on sera; quantitative polymerase chain reaction (qPCR) detection of molecular DNA in feces; and hematoxylin and eosin (H&E) stain and immunohistochemistry (IHC) on intestinal tissues. Our results showed that EPE-challenged hamsters do not develop infection when compared with PPE controls (IHC, P = 0.009; qPCR, P = 0.0003). Conversely, PPE-challenged rabbits do not develop typical intestinal lesions in comparison to EPE-challenged rabbits, with serological response at 14 DPI being significantly lower (P = 0.0023). In conclusion, PPE and EPE strains appear to have different host-specificities for hamsters and rabbits, respectively. PMID:24124268

  7. Statistical Learning Theory for High Dimensional Prediction: Application to Criterion-Keyed Scale Development

    PubMed Central

    Chapman, Benjamin P.; Weiss, Alexander; Duberstein, Paul

    2016-01-01

    Statistical learning theory (SLT) is the statistical formulation of machine learning theory, a body of analytic methods common in “big data” problems. Regression-based SLT algorithms seek to maximize predictive accuracy for some outcome, given a large pool of potential predictors, without overfitting the sample. Research goals in psychology may sometimes call for high dimensional regression. One example is criterion-keyed scale construction, where a scale with maximal predictive validity must be built from a large item pool. Using this as a working example, we first introduce a core principle of SLT methods: minimization of expected prediction error (EPE). Minimizing EPE is fundamentally different than maximizing the within-sample likelihood, and hinges on building a predictive model of sufficient complexity to predict the outcome well, without undue complexity leading to overfitting. We describe how such models are built and refined via cross-validation. We then illustrate how three common SLT algorithms–Supervised Principal Components, Regularization, and Boosting—can be used to construct a criterion-keyed scale predicting all-cause mortality, using a large personality item pool within a population cohort. Each algorithm illustrates a different approach to minimizing EPE. Finally, we consider broader applications of SLT predictive algorithms, both as supportive analytic tools for conventional methods, and as primary analytic tools in discovery phase research. We conclude that despite their differences from the classic null-hypothesis testing approach—or perhaps because of them–SLT methods may hold value as a statistically rigorous approach to exploratory regression. PMID:27454257

  8. Massive metrology using fast e-beam technology improves OPC model accuracy by >2x at faster turnaround time

    NASA Astrophysics Data System (ADS)

    Zhao, Qian; Wang, Lei; Wang, Jazer; Wang, ChangAn; Shi, Hong-Fei; Guerrero, James; Feng, Mu; Zhang, Qiang; Liang, Jiao; Guo, Yunbo; Zhang, Chen; Wallow, Tom; Rio, David; Wang, Lester; Wang, Alvin; Wang, Jen-Shiang; Gronlund, Keith; Lang, Jun; Koh, Kar Kit; Zhang, Dong Qing; Zhang, Hongxin; Krishnamurthy, Subramanian; Fei, Ray; Lin, Chiawen; Fang, Wei; Wang, Fei

    2018-03-01

    Classical SEM metrology, CD-SEM, uses low data rate and extensive frame-averaging technique to achieve high-quality SEM imaging for high-precision metrology. The drawbacks include prolonged data collection time and larger photoresist shrinkage due to excess electron dosage. This paper will introduce a novel e-beam metrology system based on a high data rate, large probe current, and ultra-low noise electron optics design. At the same level of metrology precision, this high speed e-beam metrology system could significantly shorten data collection time and reduce electron dosage. In this work, the data collection speed is higher than 7,000 images per hr. Moreover, a novel large field of view (LFOV) capability at high resolution was enabled by an advanced electron deflection system design. The area coverage by LFOV is >100x larger than classical SEM. Superior metrology precision throughout the whole image has been achieved, and high quality metrology data could be extracted from full field. This new capability on metrology will further improve metrology data collection speed to support the need for large volume of metrology data from OPC model calibration of next generation technology. The shrinking EPE (Edge Placement Error) budget places more stringent requirement on OPC model accuracy, which is increasingly limited by metrology errors. In the current practice of metrology data collection and data processing to model calibration flow, CD-SEM throughput becomes a bottleneck that limits the amount of metrology measurements available for OPC model calibration, impacting pattern coverage and model accuracy especially for 2D pattern prediction. To address the trade-off in metrology sampling and model accuracy constrained by the cycle time requirement, this paper employs the high speed e-beam metrology system and a new computational software solution to take full advantage of the large volume data and significantly reduce both systematic and random metrology errors. The new computational software enables users to generate large quantity of highly accurate EP (Edge Placement) gauges and significantly improve design pattern coverage with up to 5X gain in model prediction accuracy on complex 2D patterns. Overall, this work showed >2x improvement in OPC model accuracy at a faster model turn-around time.

  9. Evaluation of EPE Videos in Different Phases of a Learning Process

    ERIC Educational Resources Information Center

    Kolas, Line; Munkvold, Robin; Nordseth, Hugo

    2012-01-01

    The goal of the paper is to present possible use of EPE videos in different phases of a learning and teaching process. The paper is based on an evaluation of EPE (easy production educational) videos. The evaluation framework used in this study, divides the teaching and learning process into four main phases: 1) The preparation phase, 2) The…

  10. Influence of polyphenol extract from evening primrose (Oenothera paradoxa) seeds on human prostate and breast cancer cell lines.

    PubMed

    Lewandowska, Urszula; Owczarek, Katarzyna; Szewczyk, Karolina; Podsędek, Anna; Koziołkiewicz, Maria; Hrabec, Elżbieta

    2014-02-03

    There is growing interest in plant polyphenols which exhibit pleiotropic biological activities, including anti-inflammatory, antioxidant, and anticancer effects. The objective of our study was to evaluate the influence of an evening primrose extract (EPE) from defatted seeds on viability and invasiveness of three human cell lines: PNT1A (normal prostate cells), DU145 (prostate cancer cells) and MDA-MB-231 (breast cancer cells). The results revealed that after 72 h of incubation the tested extract reduced the viability of DU 145 and MDA-MB-231 with IC50 equal to 14.5 μg/mL for both cell lines. In contrast, EPE did not inhibit the viability of normal prostate cells. Furthermore, EPE reduced PNT1A and MDA-MB-231 cell invasiveness; at the concentration of 21.75 μg/mL the suppression of invasion reached 92% and 47%, respectively (versus control). Additionally, zymographic analysis revealed that after 48 h of incubation EPE inhibited metalloproteinase-2 (MMP-2) and metalloproteinase-9 (MMP-9) activities in a dose-dependent manner. For PNT1A the activities of MMP-2 and MMP-9 decreased 4- and 2-fold, respectively, at EPE concentration of 29 μg/mL. In the case of MDA-MB-231 and DU 145 the decrease in MMP-9 activity at EPE concentration of 29 μg/mL was 5.5-fold and almost 1.9-fold, respectively. In conclusion, this study suggests that EPE may exhibit antimigratory, anti-invasive and antimetastatic potential towards prostate and breast cancer cell lines.

  11. Toxicokinetics and metabolism of 1,2-diethylbenzene in male Sprague Dawley rats--part 2: evidence for in vitro and in vivo stereoselectivity of 1,2-diethylbenzene metabolism.

    PubMed

    Payan, J P; Cossec, B; Beydon, D; Fabry, J P; Ferrari, E

    2001-06-01

    In a previous study, it was shown that the neurotoxic compound 1,2-diethylbenzene (1,2-DEB) is mainly hydroxylated in the alkyl chain to give 1-(2'-ethylphenyl)ethanol (1,2-EPE) and excreted in urine of rats as two glucuronide compounds (GA1 and GA2). Some findings have suggested that the two enantiomers of 1,2-EPE are formed in vivo. In the present study, a chiral high-performance liquid chromatography method was developed to separate the two enantiomers of 1,2-EPE from a synthesized racemic mixture. Absolute configuration of both enantiomers was determined after esterification with (R)-(+)-alpha-methoxy-alpha-(trifluoromethyl)phenylacetic acid and analysis of their (1)H NMR spectra in CCl(4) added with Eu (fod)(3). The two main urinary metabolites, GA1 and GA2, from [(14)C]1,2-DEB-treated Sprague-Dawley rats (80 mg/kg, i.p.) were identified, after hydrolysis with beta-glucuronidase from Escherichia coli, as (R) and (S) glucuronide conjugates of 1,2-EPE, respectively. In vitro hydroxylation of 1,2-DEB and glucuroconjugation of 1,2-EPE were under stereoselective control in S9 fraction or microsomes from male Sprague-Dawley rat liver. The V(max) and K(m) constants for (R)1,2-EPE enantiomer formation determined in S9 fraction were greater than those for the (S) enantiomer. In the plasma of bile duct-cannulated rats, the ratio was 1.2 +/- 0.02 over the 1- to 4-h period after oral administration of [(14)C]1,2-DEB (100 mg/kg). In contrast, the glucuroconjugation rate of (S)1,2-DEB enantiomer was 4 times that of (R)1,2-EPE glucuroconjugation. A similar ratio of (R) to (S)1,2-EPE glucuronide conjugates was obtained in the plasma of bile duct-cannulated rats.

  12. A multinational study of colonization with extended spectrum β-lactamase-producing Enterobacteriaceae in healthcare personnel and family members of carrier patients hospitalized in rehabilitation centres.

    PubMed

    Adler, A; Baraniak, A; Izdebski, R; Fiett, J; Salvia, A; Samso, J V; Lawrence, C; Solomon, J; Paul, M; Lerman, Y; Schwartzberg, Y; Mordechai, E; Rossini, A; Fierro, J; Lammens, C; Malhotra-Kumar, S; Goossens, H; Hryniewicz, W; Brun-Buisson, C; Gniadkowski, M; Carmeli, Y

    2014-08-01

    The study aims were: (i) to define the prevalence of and risk factors for colonization by extended spectrum β-lactamase (ESBL) -producing Enterobacteriaceae (EPE) among healthcare workers (HCWs) and family members (FMs) of EPE-colonized patients in rehabilitation units and (ii) to compare EPE isolates from these three groups. The study included 286 FMs of 194 EPE-carrying patients identified in five rehabilitation units located in Israel, Italy, France and Spain. The EPE were detected in rectal swabs from 26 (9%) of 286 FMs screened. In multivariate analyses, older age of FM, greater mean number of hours spent with the patient, being a daughter or a female spouse of a patient, and chronic lung disease of the patient were significantly associated with carriage in the FM. Escherichia coli was the most common organism (76%), followed by Klebsiella pneumoniae (19%). Isolates were typed by pulsed field gel electrophoresis and multilocus sequence typing, and ESBLs were identified by PCR sequencing. A comparison of paired species isolates from FMs and their respective patient showed that 17 of 23 strains were indistinguishable. EPE were detected in 35 (3.5%, E. coli = 34) of the 1001 HCWs screened. Feeding patients was associated with EPE carriage by HCWs. Only 7 of 23 E. coli subclones cultured from HCWs were also represented among 376 patient-derived ESBL-producing E. coli isolates from the same rehabilitation units. In Spain, a higher proportion of HCWs and FMs were ESBL carriers than elsewhere (p <0.05). In conclusion, the molecular and epidemiological data suggest that FMs are at higher risk of EPE acquisition from their relative patients than HCWs. © 2014 The Authors Clinical Microbiology and Infection © 2014 European Society of Clinical Microbiology and Infectious Diseases.

  13. Statistical learning theory for high dimensional prediction: Application to criterion-keyed scale development.

    PubMed

    Chapman, Benjamin P; Weiss, Alexander; Duberstein, Paul R

    2016-12-01

    Statistical learning theory (SLT) is the statistical formulation of machine learning theory, a body of analytic methods common in "big data" problems. Regression-based SLT algorithms seek to maximize predictive accuracy for some outcome, given a large pool of potential predictors, without overfitting the sample. Research goals in psychology may sometimes call for high dimensional regression. One example is criterion-keyed scale construction, where a scale with maximal predictive validity must be built from a large item pool. Using this as a working example, we first introduce a core principle of SLT methods: minimization of expected prediction error (EPE). Minimizing EPE is fundamentally different than maximizing the within-sample likelihood, and hinges on building a predictive model of sufficient complexity to predict the outcome well, without undue complexity leading to overfitting. We describe how such models are built and refined via cross-validation. We then illustrate how 3 common SLT algorithms-supervised principal components, regularization, and boosting-can be used to construct a criterion-keyed scale predicting all-cause mortality, using a large personality item pool within a population cohort. Each algorithm illustrates a different approach to minimizing EPE. Finally, we consider broader applications of SLT predictive algorithms, both as supportive analytic tools for conventional methods, and as primary analytic tools in discovery phase research. We conclude that despite their differences from the classic null-hypothesis testing approach-or perhaps because of them-SLT methods may hold value as a statistically rigorous approach to exploratory regression. (PsycINFO Database Record (c) 2016 APA, all rights reserved).

  14. A stable and practical etoposide-containing intravenous long-/medium-chain triglycerides-based lipid emulsion formulation: pharmacokinetics, biodistribution, toxicity, and antitumor efficacy.

    PubMed

    Dong, Wenna; Zhang, Luna; Niu, Yantao; Fan, Dongjiao; Wu, Xiaorong; Tang, Xing; Cai, Cuifang

    2013-05-01

    This work aimed to evaluate pharmacokinetics, biodistribution, toxicity, and antitumor activities of a highly stable long-/medium-chain triglycerides (LCT/MCT)-based etoposide parenteral emulsion (EPE) in comparison to etoposide parenteral solution (EPS). Using high-pressure homogenization method, EPE was prepared and sterilized at 121°C for 10 min by autoclaving. The biological samples were analyzed using the UPLC-ESI-MS/MS method. Superior stability of EPE was verified with no significant changes in physicochemical properties in the accelerating and long-term stability tests. Similar pharmacokinetic behavior in beagle dogs was obtained and the AUC 0 - 12h values were 1196.73 ± 320.85 and 1505.56 ± 617.93 µg.h/L for EPE and EPS (p > 0.5), respectively. Likewise, no remarkable difference in biodistribution profiles in mice was found for both formulations. Safety assessment studies including hemolysis test, rabbit ear vein test and injection anaphylaxis were undertaken and the EPE was proven to be safe for intravenous administration. Specifically, after consecutive 12 weeks administration in rats, systematic and local toxicity induced by EPE were alleviated relative to that of EPS. Furthermore, significant and comparable antitumor activities to EPS were also demonstrated by EPE with tumor suppression rate (TSR) of 66.63, 55.94, and 60.16% against H460, Hep G2, and BCAP-37 human cancer cell lines in nude mice at the dose of 15 mg/kg, respectively. These results suggest that this LCT/MCT-based lipid emulsion is a promising alternative intravenous carrier for etoposide with high stability, improved convenience, alleviated toxicity, and noncompromised antitumor efficacy.

  15. Oenothera paradoxa defatted seeds extract containing pentagalloylglucose and procyanidins potentiates the cytotoxicity of vincristine.

    PubMed

    Jaszewska, E; Kosmider, A; Kiss, A K; Naruszewicz, M

    2010-10-01

    The purpose of the study was a comparison of Oenothera paradoxa Hudziok defatted seeds extract (EPE) effect with the activity of individual constituents of the extract: pentagalloylglucose (PGG), gallic acid, (+)-catechin and the procyanidin fraction, as well as an assessment of the combined effect of EPE and vincristine (VCR) in the absence or presence of MRP1 (indomethacin) and P-glycoprotein (verapamil) inhibitors, on two human cancer cell lines, metastatic melanoma (HTB-140) and hepatoma (HepG2). The presence of EPE, PGG and procyanidins caused a marked reduction in viability (MTT assay) and rise in mortality (LDH release assay) of HTB-140 cells. The combined use of EPE (25 μg/mL) and VCR (1 μM) in HTB-140 and HepG2 cells produced an increased cytotoxicity as compared to vincristine alone - by more than 4 and 1.5 times, respectively. In HTB-140 cells, the level of intracellular ATP (measured by bioluminescence) was lowered over 7-fold as a result of exposure to the combination of EPE and VCR, while the addition of MRP-1 inhibitor did not cause an increased cytotoxicity or further lowering of the ATP level. Our results demonstrate that EPE, containing PGG and procyanidins, significantly increased the sensitivity of cancer cells, particularly the melanoma cells, to the action of vincristine.

  16. Development and Validation of UV-Visible Spectrophotometric Method for Simultaneous Determination of Eperisone and Paracetamol in Solid Dosage Form.

    PubMed

    Khanage, Shantaram Gajanan; Mohite, Popat Baban; Jadhav, Sandeep

    2013-01-01

    Eperisone Hydrochloride (EPE) is a potent new generation antispasmodic drug which is used in the treatment of moderate to severe pain in combination with Paracetamol (PAR). Both drugs are available in tablet dosage form in combination with a dose of 50 mg for EPE and 325 mg PAR respectively. The method is based upon Q-absorption ratio method for the simultaneous determination of the EPE and PAR. Absorption ratio method is used for the ratio of the absorption at two selected wavelength one of which is the iso-absorptive point and other being the λmax of one of the two components. EPE and PAR shows their iso-absorptive point at 260 nm in methanol, the second wavelength used is 249 nm which is the λmax of PAR in methanol. The linearity was obtained in the concentration range of 5-25 μg/mL for EPE and 2-10 μg/mL for PAR. The proposed method was effectively applied to tablet dosage form for estimation of both drugs. The accuracy and reproducibility results are close to 100% with 2% RSD. RESULTS of the analysis were validated statistically and found to be satisfactory. The results of proposed method have been validated as per ICH guidelines. A simple, precise and economical spectrophotometric method has been developed for the estimation of EPE and PAR in pharmaceutical formulation.

  17. Transperineal prostate biopsy under magnetic resonance image guidance: a needle placement accuracy study.

    PubMed

    Blumenfeld, Philip; Hata, Nobuhiko; DiMaio, Simon; Zou, Kelly; Haker, Steven; Fichtinger, Gabor; Tempany, Clare M C

    2007-09-01

    To quantify needle placement accuracy of magnetic resonance image (MRI)-guided core needle biopsy of the prostate. A total of 10 biopsies were performed with 18-gauge (G) core biopsy needle via a percutaneous transperineal approach. Needle placement error was assessed by comparing the coordinates of preplanned targets with the needle tip measured from the intraprocedural coherent gradient echo images. The source of these errors was subsequently investigated by measuring displacement caused by needle deflection and needle susceptibility artifact shift in controlled phantom studies. Needle placement error due to misalignment of the needle template guide was also evaluated. The mean and standard deviation (SD) of errors in targeted biopsies was 6.5 +/- 3.5 mm. Phantom experiments showed significant placement error due to needle deflection with a needle with an asymmetrically beveled tip (3.2-8.7 mm depending on tissue type) but significantly smaller error with a symmetrical bevel (0.6-1.1 mm). Needle susceptibility artifacts observed a shift of 1.6 +/- 0.4 mm from the true needle axis. Misalignment of the needle template guide contributed an error of 1.5 +/- 0.3 mm. Needle placement error was clinically significant in MRI-guided biopsy for diagnosis of prostate cancer. Needle placement error due to needle deflection was the most significant cause of error, especially for needles with an asymmetrical bevel. (c) 2007 Wiley-Liss, Inc.

  18. Model based high NA anamorphic EUV RET

    NASA Astrophysics Data System (ADS)

    Jiang, Fan; Wiaux, Vincent; Fenger, Germain; Clifford, Chris; Liubich, Vlad; Hendrickx, Eric

    2018-03-01

    With the announcement of the extension of the Extreme Ultraviolet (EUV) roadmap to a high NA lithography tool that utilizes anamorphic optics design, an investigation of design tradeoffs unique to the imaging of anamorphic lithography tool is shown. An anamorphic optical proximity correction (OPC) solution has been developed that models fully the EUV near field electromagnetic effects and the anamorphic imaging using the Domain Decomposition Method (DDM). Clips of imec representative for the N3 logic node were used to demonstrate the OPC solutions on critical layers that will benefit from the increased contrast at high NA using anamorphic imaging. However, unlike isomorphic case, from wafer perspective, OPC needs to treat x and y differently. In the paper, we show a design trade-off seen unique to Anamorphic EUV, namely that using a mask rule of 48nm (mask scale), approaching current state of the art, limitations are observed in the available correction that can be applied to the mask. The metal pattern has a pitch of 24nm and CD of 12nm. During OPC, the correction of the metal lines oriented vertically are being limited by the mask rule of 12nm 1X. The horizontally oriented lines do not suffer from this mask rule limitation as the correction is allowed to go to 6nm 1X. For this example, the masks rules will need to be more aggressive to allow complete correction, or design rules and wafer processes (wafer rotation) would need to be created that utilize the orientation that can image more aggressive features. When considering VIA or block level correction, aggressive polygon corner to corner designs can be handled with various solutions, including applying a 45 degree chop. Multiple solutions are discussed with the metrics of edge placement error (EPE) and Process Variation Bands (PVBands), together with all the mask constrains. Noted in anamorphic OPC, the 45 degree chop is maintained at the mask level to meet mask manufacturing constraints, but results in skewed angle edge in wafer level correction. In this paper, we used both contact (Via/block) patterns and metal patterns for OPC practice. By comparing the EPE of horizontal and vertical patterns with a fixed mask rule check (MRC), and the PVBand, we focus on the challenges and the solutions of OPC with anamorphic High-NA lens.

  19. Effect of the Egyptian propolis on the hepatic antioxidant defense and pro-apoptotic p53 and anti-apoptotic bcl2 expressions in aflatoxin B1 treated male mice.

    PubMed

    Alm-Eldeen, Abeer A; Basyony, Mohammed A; Elfiky, Nabil K; Ghalwash, Mohamed M

    2017-03-01

    Aflatoxins are potent hepatotoxic due to their role in producing reactive oxygen species and consequently peroxidative damage. Propolis is a honey bee product known for its antioxidant capacity. The aim of this study was to verify the antioxidant effect of the Egyptian propolis extract (EPE) against aflatoxin B1 (AFB1)-induced hepatotoxicity in mice. Forty eight male mice were divided: first, second and third groups were used as control receiving saline, olive oil and EPE respectively, fourth was AFB1 group, fifth and sixth received EPE post or pre AFB1 treatment, respectively. EPE was given as (0.2mg/kg) 3 times a week. AFB1 was given as a single dose (0.25μg/kg). After 2 weeks, the mice were scarified and biochemical, histopathological and immunohistochemical investigations were assessed. EPE has a high content of total phenolics and alkaloids. The inhibitory concentration 50 (IC50) value for DPPH radical scavenging was 1353.8μg/mL. Pretreatment with EPE improved AFB1-induced hepatotoxicity represented in lowering alanine transaminase, aspartate aminotransferase, alkaline phosphatase, cholesterol, triglycerides, lipid peroxidation and pro-apoptotic p53 expression to 33.48±1.98 IU/ml, 53.00±2.37 IU/ml, 123.50±2.02 IU/ml, 76.50±2.66mg/dl, 54.00±3.03mg/dl, 2.22±0.14 nmol/g and 4.31±2.1 cells/field and raising the reduced glutathione, catalase, superoxide dismutase and anti-apoptotic bcl2 expression to 3.37±1.65 nmol/g, 4.92±0.25 nmol/g, 57±0.91UI/g and 39.7±5.9 cells/field which all had non-significant differences with the control, respectively. In conclusion, EPE can attenuate aflatoxin B1-induced hepatotoxicity in mice. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  20. Re-evaluating the concept of "dominant/index tumor nodule" in multifocal prostate cancer.

    PubMed

    Huang, Cheng Cheng; Deng, Fang-Ming; Kong, Max X; Ren, Qinhu; Melamed, Jonathan; Zhou, Ming

    2014-05-01

    Prostate cancer (PCa) often presents as a multifocal disease with heterogeneity in Gleason score (GS) and genetic alterations. Dominant/index tumor nodule (DN), the largest nodule in a multifocal disease, is presumed to harbor the most aggressive biological behavior and therefore dictate the overall clinical behavior of PCa. In this study, we examined the pathological features of DN and re-evaluated the validity of the "DN" concept in multifocal PCa. A total of 201 consecutive radical prostatectomy specimens were totally submitted and examined. All independent cancer foci were recorded with prognostically important pathological parameters. Unifocal and multifocal disease was present in 25 (12.4 %) and 176 (87.6 %) cases, respectively. In 20 (11.3 %) multifocal cases, the highest GS, the largest tumor volume (TV), and extraprostatic extension (EPE) did not concur in the same tumor nodules. Non-DNs had a higher GS and EPE in 13 cases each and had both the highest GS and EPE in 5 cases. In the majority of multifocal prostate cancer (88.7 %), DNs have the highest GS and EPE. In these cases, DN is still a valid concept and can be used for assigning overall GS and procuring tissue for research. However, in a significant number of cases (11.3 %), the largest TV, the highest GS, and EPE did not concur in the same tumor nodules. In these cases, pathologists should de-emphasize the concept of DN. Instead, they should place the emphasis on the multifocal nature of the disease and document the pathological features of all independent tumor foci that have the largest TV, the highest GS, and EPE.

  1. The effect of toe marker placement error on joint kinematics and muscle forces using OpenSim gait simulation.

    PubMed

    Xu, Hang; Merryweather, Andrew; Bloswick, Donald; Mao, Qi; Wang, Tong

    2015-01-01

    Marker placement can be a significant source of error in biomechanical studies of human movement. The toe marker placement error is amplified by footwear since the toe marker placement on the shoe only relies on an approximation of underlying anatomical landmarks. Three total knee replacement subjects were recruited and three self-speed gait trials per subject were collected. The height variation between toe and heel markers of four types of footwear was evaluated from the results of joint kinematics and muscle forces using OpenSim. The reference condition was considered as the same vertical height of toe and heel markers. The results showed that the residual variances for joint kinematics had an approximately linear relationship with toe marker placement error for lower limb joints. Ankle dorsiflexion/plantarflexion is most sensitive to toe marker placement error. The influence of toe marker placement error is generally larger for hip flexion/extension and rotation than hip abduction/adduction and knee flexion/extension. The muscle forces responded to the residual variance of joint kinematics to various degrees based on the muscle function for specific joint kinematics. This study demonstrates the importance of evaluating marker error for joint kinematics and muscle forces when explaining relative clinical gait analysis and treatment intervention.

  2. Sub-isotypic differences in the immunoglobulin G response to Lawsonia intracellularis in vaccinated, seropositive, and equine proliferative enteropathy-affected horses.

    PubMed

    Page, Allen E; Stills, Harold F; Horohov, David W

    2014-12-15

    In the horse, Lawsonia intracellularis infection results in equine proliferative enteropathy (EPE). While upwards of 100% of weanlings on an endemic farm may seroconvert, only a small percentage (approximately 5%) will develop clinical disease. Cell-mediated immune mechanisms likely play a role in resistance to L. intracellularis and the absence of a L. intracellularis-specific IFN-γ response has been associated with the development of EPE. The goal of this study was to determine whether protection from clinical EPE is associated with the induction of a systemic IgG sub-isotypic response consistent with a Th1-type cytokine response. To describe their L. intracellularis/EPE status, horses enrolled in this study were placed into one of three categories: seropositive-only, vaccinated, and presumptive clinical EPE. An existing ELISA method was modified to detect L. intracellularis-specific IgG(a), IgG(b), and IgG(t) antibodies using the mouse anti-equine hybridomas CVS-48, CVS-39, and CVS-40, respectively. Additionally, the existing ELISA method was used to quantify total IgG antibodies specific for L. intracellularis for comparison between the groups. Total L. intracellularis-specific IgG was found to be significantly higher (p<0.05) in presumptive clinical EPE cases (n=21) when compared with seropositive (exposed but unaffected) (n=36) and vaccinated horses (n=27). Further, a similar pattern for IgG(a) was seen in that the presumptive clinical EPE horses had significantly more L. intracellularis-specific IgG(a) (p<0.05) than the seropositive or vaccinated horses. With IgG(b), however, the vaccinated horses had significantly more IgG(b) (p<0.05) than the presumptive clinical or seropositive horses. No L. intracellularis-specific IgG(t) was detected in samples from any of the groups. While the results presented here with respect to IgG(a) response in the presumptive clinical EPE group were expected, a higher concentration of IgG(a) was anticipated in the seropositive horses that failed to develop clinical disease as well as in the vaccinated horses. Future work utilizing newer reagents against a broader range of equine IgG sub-isotypes may provide additional information once these become commercially available. Copyright © 2014 Elsevier B.V. All rights reserved.

  3. Automatic Correction of Adverb Placement Errors for CALL

    ERIC Educational Resources Information Center

    Garnier, Marie

    2012-01-01

    According to recent studies, there is a persistence of adverb placement errors in the written productions of francophone learners and users of English at an intermediate to advanced level. In this paper, we present strategies for the automatic detection and correction of errors in the placement of manner adverbs, using linguistic-based natural…

  4. Self-aligned blocking integration demonstration for critical sub-30nm pitch Mx level patterning with EUV self-aligned double patterning

    NASA Astrophysics Data System (ADS)

    Raley, Angélique; Lee, Joe; Smith, Jeffrey T.; Sun, Xinghua; Farrell, Richard A.; Shearer, Jeffrey; Xu, Yongan; Ko, Akiteru; Metz, Andrew W.; Biolsi, Peter; Devilliers, Anton; Arnold, John; Felix, Nelson

    2018-04-01

    We report a sub-30nm pitch self-aligned double patterning (SADP) integration scheme with EUV lithography coupled with self-aligned block technology (SAB) targeting the back end of line (BEOL) metal line patterning applications for logic nodes beyond 5nm. The integration demonstration is a validation of the scalability of a previously reported flow, which used 193nm immersion SADP targeting a 40nm pitch with the same material sets (Si3N4 mandrel, SiO2 spacer, Spin on carbon, spin on glass). The multi-color integration approach is successfully demonstrated and provides a valuable method to address overlay concerns and more generally edge placement error (EPE) as a whole for advanced process nodes. Unbiased LER/LWR analysis comparison between EUV SADP and 193nm immersion SADP shows that both integrations follow the same trend throughout the process steps. While EUV SADP shows increased LER after mandrel pull, metal hardmask open and dielectric etch compared to 193nm immersion SADP, the final process performance is matched in terms of LWR (1.08nm 3 sigma unbiased) and is only 6% higher than 193nm immersion SADP for average unbiased LER. Using EUV SADP enables almost doubling the line density while keeping most of the remaining processes and films unchanged, and provides a compelling alternative to other multipatterning integrations, which present their own sets of challenges.

  5. Distant and Regional Atmospheric Circulation Influences Governing Integrated Water Vapor Transport and the Occurrence of Extreme Precipitation Events

    NASA Astrophysics Data System (ADS)

    Bosart, L. F.; Papin, P. P.; Bentley, A. M.

    2017-12-01

    This presentation will show how the evolution of the large-scale and regional-scale atmospheric circulation contributes to the occurrence of extreme precipitation events (EPEs). An EPE requires that tropospheric moisture flux convergence (MFC) and the associated removal of hydrometeors be balanced by moisture replenishment via integrated (water) vapor transport (IVT) to continuously replenish condensed moisture. Moisture source regions may be distant or regional. Distant moisture sources may require the interaction of lower- and upper-level jet streams with a pre-existing mobile atmospheric disturbance to produce sufficient lift to condense moisture. Pre-existing regional moisture sources may require frontal lifting the presence of MFC to condense moisture. In cases of long-range IVT, such as moisture from a western North Pacific typhoon being drawn poleward along an atmospheric river (AR) toward the west coast of North America, moisture may be transported 1000s of kilometers along a low-level jet before a combination of dynamic and orographic lift results in an EPE. Alternatively, in the case of a typical summer warm and humid air mass over the continental United States, unused moisture may exist for several days in this air mass before sufficient MFC associated with a thermally direct mesoscale frontal circulation can concentrate and condense the moisture. In this case, there may be no long-range IVT via ARs. Instead, the atmospheric circulations may evolve to produce sustained MFC associated with mesoscale frontal circulations, especially in the presence of complex terrain, to produce an EPE. During this presentation, examples of EPEs associated with long-range IVT and distant MFC versus EPEs associated with regional MFC and mesoscale frontal circulations will be illustrated.

  6. Frequent acquisition of low-virulence strains of ESBL-producing Escherichia coli in travellers.

    PubMed

    Vading, M; Kabir, M H; Kalin, M; Iversen, A; Wiklund, S; Nauclér, P; Giske, C G

    2016-12-01

    International travel is a risk factor for intestinal colonization with ESBL-producing Enterobacteriaceae (EPE). This prospective cohort study focuses on molecular features of and risk factors for travel-acquired EPE. Rectal swabs and survey data were collected from 188 Swedes travelling to four regions of high EPE prevalence. Samples were plated onto selective agars. ESBL producers were determined using phenotypic methods. Molecular characterization regarding virulence factors and phylogenetic grouping of ESBL-producing Escherichia coli was done using PCR. Isolates were also screened for the plasmid-mediated colistin resistance gene mcr-1. Among 175 pre-travel EPE-negative participants, 32% were positive upon return. No carbapenemase-producing Enterobacteriaceae were found, but one CTX-M-producing E. coli harboured mcr-1 (travel to Thailand). Most E. coli strains (43.1%) belonged to phylogroup A and were rarely associated with extraintestinal infections and a few (9.2%) expressed uropathogenicity pap genes. During 10-26 months of follow-up, no clinical infections were observed. Colonization rates varied by visited region: the Indian subcontinent, 49.2%; northern Africa, 44.0%; South-East Asia, 19.1%; and Turkey, 9.5%. Travellers' diarrhoea (OR 2.5, P = 0.04) or antimicrobial treatment during the trip (OR 5.9, P = 0.02) were both independent risk factors for EPE colonization. EPE acquired during travel have seemingly low pathogenicity, possibly indicating a low risk of clinical infection. Pre-travel advice should emphasize avoiding unnecessary antibiotic treatment during travel. © The Author 2016. Published by Oxford University Press on behalf of the British Society for Antimicrobial Chemotherapy. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.

  7. Accuracy Study of a Robotic System for MRI-guided Prostate Needle Placement

    PubMed Central

    Seifabadi, Reza; Cho, Nathan BJ.; Song, Sang-Eun; Tokuda, Junichi; Hata, Nobuhiko; Tempany, Clare M.; Fichtinger, Gabor; Iordachita, Iulian

    2013-01-01

    Background Accurate needle placement is the first concern in percutaneous MRI-guided prostate interventions. In this phantom study, different sources contributing to the overall needle placement error of a MRI-guided robot for prostate biopsy have been identified, quantified, and minimized to the possible extent. Methods and Materials The overall needle placement error of the system was evaluated in a prostate phantom. This error was broken into two parts: the error associated with the robotic system (called before-insertion error) and the error associated with needle-tissue interaction (called due-to-insertion error). The before-insertion error was measured directly in a soft phantom and different sources contributing into this part were identified and quantified. A calibration methodology was developed to minimize the 4-DOF manipulator’s error. The due-to-insertion error was indirectly approximated by comparing the overall error and the before-insertion error. The effect of sterilization on the manipulator’s accuracy and repeatability was also studied. Results The average overall system error in phantom study was 2.5 mm (STD=1.1mm). The average robotic system error in super soft phantom was 1.3 mm (STD=0.7 mm). Assuming orthogonal error components, the needle-tissue interaction error was approximated to be 2.13 mm thus having larger contribution to the overall error. The average susceptibility artifact shift was 0.2 mm. The manipulator’s targeting accuracy was 0.71 mm (STD=0.21mm) after robot calibration. The robot’s repeatability was 0.13 mm. Sterilization had no noticeable influence on the robot’s accuracy and repeatability. Conclusions The experimental methodology presented in this paper may help researchers to identify, quantify, and minimize different sources contributing into the overall needle placement error of an MRI-guided robotic system for prostate needle placement. In the robotic system analyzed here, the overall error of the studied system remained within the acceptable range. PMID:22678990

  8. Accuracy study of a robotic system for MRI-guided prostate needle placement.

    PubMed

    Seifabadi, Reza; Cho, Nathan B J; Song, Sang-Eun; Tokuda, Junichi; Hata, Nobuhiko; Tempany, Clare M; Fichtinger, Gabor; Iordachita, Iulian

    2013-09-01

    Accurate needle placement is the first concern in percutaneous MRI-guided prostate interventions. In this phantom study, different sources contributing to the overall needle placement error of a MRI-guided robot for prostate biopsy have been identified, quantified and minimized to the possible extent. The overall needle placement error of the system was evaluated in a prostate phantom. This error was broken into two parts: the error associated with the robotic system (called 'before-insertion error') and the error associated with needle-tissue interaction (called 'due-to-insertion error'). Before-insertion error was measured directly in a soft phantom and different sources contributing into this part were identified and quantified. A calibration methodology was developed to minimize the 4-DOF manipulator's error. The due-to-insertion error was indirectly approximated by comparing the overall error and the before-insertion error. The effect of sterilization on the manipulator's accuracy and repeatability was also studied. The average overall system error in the phantom study was 2.5 mm (STD = 1.1 mm). The average robotic system error in the Super Soft plastic phantom was 1.3 mm (STD = 0.7 mm). Assuming orthogonal error components, the needle-tissue interaction error was found to be approximately 2.13 mm, thus making a larger contribution to the overall error. The average susceptibility artifact shift was 0.2 mm. The manipulator's targeting accuracy was 0.71 mm (STD = 0.21 mm) after robot calibration. The robot's repeatability was 0.13 mm. Sterilization had no noticeable influence on the robot's accuracy and repeatability. The experimental methodology presented in this paper may help researchers to identify, quantify and minimize different sources contributing into the overall needle placement error of an MRI-guided robotic system for prostate needle placement. In the robotic system analysed here, the overall error of the studied system remained within the acceptable range. Copyright © 2012 John Wiley & Sons, Ltd.

  9. "The Father Says No?"

    ERIC Educational Resources Information Center

    Hittman, Michael

    2009-01-01

    In order to account for several puzzling, if not inexplicable, things that happened to the author while researching the life and times of Wovoka, also known as Jack Wilson, 1890 Ghost Dance prophet, he proposes the neologism "extraordinary personal experience" (EPE). An EPE, simply put, references events and circumstances that occur during and…

  10. Dry-plasma-free chemical etch technique for variability reduction in multi-patterning (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Kal, Subhadeep; Mohanty, Nihar; Farrell, Richard A.; Franke, Elliott; Raley, Angelique; Thibaut, Sophie; Pereira, Cheryl; Pillai, Karthik; Ko, Akiteru; Mosden, Aelan; Biolsi, Peter

    2017-04-01

    Scaling beyond the 7nm technology node demands significant control over the variability down to a few angstroms, in order to achieve reasonable yield. For example, to meet the current scaling targets it is highly desirable to achieve sub 30nm pitch line/space features at back-end of the line (BEOL) or front end of line (FEOL); uniform and precise contact/hole patterning at middle of line (MOL). One of the quintessential requirements for such precise and possibly self-aligned patterning strategies is superior etch selectivity between the target films while other masks/films are exposed. The need to achieve high etch selectivity becomes more evident for unit process development at MOL and BEOL, as a result of low density films choices (compared to FEOL film choices) due to lower temperature budget. Low etch selectivity with conventional plasma and wet chemical etch techniques, causes significant gouging (un-intended etching of etch stop layer, as shown in Fig 1), high line edge roughness (LER)/line width roughness (LWR), non-uniformity, etc. In certain circumstances this may lead to added downstream process stochastics. Furthermore, conventional plasma etches may also have the added disadvantage of plasma VUV damage and corner rounding (Fig. 1). Finally, the above mentioned factors can potentially compromise edge placement error (EPE) and/or yield. Therefore a process flow enabled with extremely high selective etches inherent to film properties and/or etch chemistries is a significant advantage. To improve this etch selectivity for certain etch steps during a process flow, we have to implement alternate highly selective, plasma free techniques in conjunction with conventional plasma etches (Fig 2.). In this article, we will present our plasma free, chemical gas phase etch technique using chemistries that have high selectivity towards a spectrum of films owing to the reaction mechanism ( as shown Fig 1). Gas phase etches also help eliminate plasma damage to the features during the etch process. Herein we will also demonstrate a test case on how a combination or plasma assisted and plasma free etch techniques has the potential to improve process performance of a 193nm immersion based self aligned quandruple patterning (SAQP) for BEOL compliant films (an example shown in Fig 2). In addition, we will also present on the application of gas etches for (1) profile improvement, (2) selective mandrel pull (3) critical dimension trim of mandrels, with an analysis of advantages over conventional techniques in terms of LER and EPE.

  11. SU-F-T-320: Assessing Placement Error of Optically Stimulated Luminescent in Vivo Dosimeters Using Cone-Beam Computed Tomography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Riegel, A; Klein, E; Tariq, M

    Purpose: Optically-stimulated luminescent dosimeters (OSLDs) are increasingly utilized for in vivo dosimetry of complex radiation delivery techniques such as intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy (VMAT). Evaluation of clinical uncertainties such as placement error has not been performed. This work retrospectively investigates the magnitude of placement error using conebeam computed tomography (CBCT) and its effect on measured/planned dose agreement. Methods: Each OSLD was placed at a physicist-designated location on the patient surface on a weekly basis. The location was given in terms of a gantry angle and two-dimensional offset from central axis. The OSLDs were placed before dailymore » image guidance. We identified 77 CBCTs from 25 head-and-neck patients who received IMRT or VMAT, where OSLDs were visible on the CT image. Grossly misplaced OSLDs were excluded (e.g. wrong laterality). CBCTs were registered with the treatment plan and the distance between the planned and actual OSLD location was calculated in two dimensions in the beam’s eye view. Distances were correlated with measured/planned dose percent differences. Results: OSLDs were grossly misplaced for 5 CBCTs (6.4%). For the remaining 72 CBCTs, average placement error was 7.0±6.0 mm. These errors were not correlated with measured/planned dose percent differences (R{sup 2}=0.0153). Generalizing the dosimetric effect of placement errors may be unreliable. Conclusion: Correct placement of OSLDs for IMRT and VMAT treatments is critical to accurate and precise in vivo dosimetry. Small placement errors could produce large disagreement between measured and planned dose. Further work includes expansion to other treatment sites, examination of planned dose at the actual point of OSLD placement, and the influence of imageguided shifts on measured/planned dose agreement.« less

  12. Pattern optimizing verification of self-align quadruple patterning

    NASA Astrophysics Data System (ADS)

    Yamato, Masatoshi; Yamada, Kazuki; Oyama, Kenichi; Hara, Arisa; Natori, Sakurako; Yamauchi, Shouhei; Koike, Kyohei; Yaegashi, Hidetami

    2017-03-01

    Lithographic scaling continues to advance by extending the life of 193nm immersion technology, and spacer-type multi-patterning is undeniably the driving force behind this trend. Multi-patterning techniques such as self-aligned double patterning (SADP) and self-aligned quadruple patterning (SAQP) have come to be used in memory devices, and they have also been adopted in logic devices to create constituent patterns in the formation of 1D layout designs. Multi-patterning has consequently become an indispensible technology in the fabrication of all advanced devices. In general, items that must be managed when using multi-patterning include critical dimension uniformity (CDU), line edge roughness (LER), and line width roughness (LWR). Recently, moreover, there has been increasing focus on judging and managing pattern resolution performance from a more detailed perspective and on making a right/wrong judgment from the perspective of edge placement error (EPE). To begin with, pattern resolution performance in spacer-type multi-patterning is affected by the process accuracy of the core (mandrel) pattern. Improving the controllability of CD and LER of the mandrel is most important, and to reduce LER, an appropriate smoothing technique should be carefully selected. In addition, the atomic layer deposition (ALD) technique is generally used to meet the need for high accuracy in forming the spacer film. Advances in scaling are accompanied by stricter requirements in the controllability of fine processing. In this paper, we first describe our efforts in improving controllability by selecting the most appropriate materials for the mandrel pattern and spacer film. Then, based on the materials selected, we present experimental results on a technique for improving etching selectivity.

  13. The Political Uses of Sign Language: The Case of the French Revolution

    ERIC Educational Resources Information Center

    Rosenfeld, Sophia

    2005-01-01

    The story of the Abbe de l'Epee's "methodical signs" is best known as a key moment in Deaf history. However, at the time of the French Revolution this story served a larger political function. The example of de l'Epee's deaf students, and their seemingly miraculous command of ideas learned through gestural signs, helped the French…

  14. Surface characterization of graphene based materials

    NASA Astrophysics Data System (ADS)

    Pisarek, M.; Holdynski, M.; Krawczyk, M.; Nowakowski, R.; Roguska, A.; Malolepszy, A.; Stobinski, L.; Jablonski, A.

    2016-12-01

    In the present study, two kind of samples were used: (i) a monolayer graphene film with a thickness of 0.345 nm deposited by the CVD method on Cu foil, (ii) graphene flakes obtained by modified Hummers method and followed by reduction of graphene oxide. The inelastic mean free path (IMFP), characterizing electron transport in graphene/Cu sample and reduced graphene oxide material, which determines the sampling depth of XPS and AES were evaluated from relative Elastic Peak Electron Spectroscopy (EPES) measurements with the Au standard in the energy range 0.5-2 keV. The measured IMFPs were compared with IMFPs resulting from experimental optical data published in the literature for the graphite sample. The EPES IMFP values at 0.5 and 1.5 keV was practically identical to that calculated from optical data for graphite (less than 4% deviation). For energies 1 and 2 keV, the EPES IMFPs for rGO were deviated up to 14% from IMFPs calculated using the optical data by Tanuma et al. [1]. Before EPES measurements all samples were characterized by various techniques like: FE-SEM, AFM, XPS, AES and REELS to visualize the surface morphology/topography and identify the chemical composition.

  15. Effect of propolis in gastric disorders: inhibition studies on the growth of Helicobacter pylori and production of its urease.

    PubMed

    Baltas, Nimet; Karaoglu, Sengul Alpay; Tarakci, Cemre; Kolayli, Sevgi

    2016-01-01

    There is considerable interest in alternative approaches to inhibit Helicobacter pylori (H. pylori) and thus treat many stomach diseases. Propolis is a pharmaceutical mixture containing many natural bioactive substances. The aim of this study was to use propolis samples to treat H. pylori. The anti-H. pylori and anti-urease activities of 15 different ethanolic propolis extracts (EPEs) were tested. The total phenolic contents and total flavonoid contents of the EPE were also measured. The agar-well diffusion assay was carried out on H. pylori strain J99 and the inhibition zones were measured and compared with standards. All propolis extracts showed high inhibition of H. pylori J99, with inhibition diameters ranging from 31.0 to 47.0 mm. Helicobacter pylori urease inhibitory activity was measured using the phenol-hypochlorite assay; all EPEs showed significant inhibition against the enzyme, with inhibition concentrations (IC 50 ; mg/mL) ranging from 0.260 to 1.525 mg/mL. The degree of inhibition was related to the phenolic content of the EPE. In conclusion, propolis extract was found to be a good inhibitor that can be used in H. pylori treatment to improve human health.

  16. Embracing Errors in Simulation-Based Training: The Effect of Error Training on Retention and Transfer of Central Venous Catheter Skills.

    PubMed

    Gardner, Aimee K; Abdelfattah, Kareem; Wiersch, John; Ahmed, Rami A; Willis, Ross E

    2015-01-01

    Error management training is an approach that encourages exposure to errors during initial skill acquisition so that learners can be equipped with important error identification, management, and metacognitive skills. The purpose of this study was to determine how an error-focused training program affected performance, retention, and transfer of central venous catheter (CVC) placement skills when compared with traditional training methodologies. Surgical interns (N = 30) participated in a 1-hour session featuring an instructional video and practice performing internal jugular (IJ) and subclavian (SC) CVC placement with guided instruction. All interns underwent baseline knowledge and skill assessment for IJ and SC (pretest) CVC placement; watched a "correct-only" (CO) or "correct + error" (CE) instructional video; practiced for 30 minutes; and were posttested on knowledge and IJ and SC CVC placement. Skill retention and transfer (femoral CVC placement) were assessed 30 days later. All skills tests (pretest, posttest, and transfer) were videorecorded and deidentified for evaluation by a single blinded instructor using a validated 17-item checklist. Both the groups exhibited significant improvements (p < 0.001) in knowledge and skills after the 1-hour training program, but the increase of items achieved on the performance checklist did not differ between conditions (CO: IJ Δ = 35%, SC Δ = 29%; CE: IJ Δ = 36%, subclavian Δ = 33%). However, 1 month later, the CO group exhibited significant declines in skill retention on IJ CVC placement (from 68% at posttraining to 44% at day 30; p < 0.05) and SC CVC placement (from 63% at posttraining to 49% at day 30; p < 0.05), whereas the CE group did not have significant decreases in performance. The CE group performed significantly better on femoral CVC placement (i.e., transfer task; 62% vs 38%; p < 0.01) and on 2 of the 3 complication scenarios (p < 0.05) when compared with the CO group. These data indicate that incorporating error-based activities and discussions into training programs can be beneficial for skill retention and transfer. Copyright © 2015 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.

  17. An Examination of the Relationship between Enjoyment, Physical Education, Physical Activity and Health in Irish Adolescents

    ERIC Educational Resources Information Center

    Woods, Catherine B.; Tannehill, Deborah; Walsh, Julia

    2012-01-01

    Enjoyment of physical activity (EPA) is positively correlated with activity, yet little is known of its relationship with enjoyment of physical education (EPE). This study's purpose was to explore EPE and its relationship to EPA. Cross-sectional data (N = 4122, average age 14.5 plus or minus 1.7 years, 48% male) were collected as part of the CSPPA…

  18. Stimuli-responsive Materials and Structures with Electrically Tunable Mechanical Properties

    NASA Astrophysics Data System (ADS)

    Auletta, Jeffrey Thomas

    Electricity, a convenient stimulus, was used to manipulate the mechanical properties of two classes of materials, each with a different mechanism. In the first system, macroscale electroplastic elastomer hydrogels (EPEs) were reversibly cycled through soft and hard states by sequential application of oxidative and reductive potentials. Electrochemically reversible crosslinks were switched between strongly binding Fe3+ and weak to non-binding Fe2+, as determined by potentiometric titration.With the incorporation of graphene oxide (GO) into the EPE, a significant enhancement in modulus and toughness was observed, allowing for the preparation of thinner EPE samples, which could be reversibly cycled between soft and hard states over 30 minutes. Further characterization of this EPE by magnetic susceptibility measurements suggested the formation of multinuclear iron clusters within the gel. Copper-derived EPEs which exploited the same redox-controlled mechanism for switching between hard and soft states were also prepared. Here, the density of temporary crosslinks and the mechanical properties were controlled by reversibly switching between the +1 and +2 oxidation states, using a combination of electrochemical/air oxidation and chemical reduction. In addition to undergoing redox-controlled changes in modulus, these EPEs exhibited shape memory. In the second system, electroadhesion between ionomer layers was exploited to create laminate structures whose rigidity depended on the reversible polarization of the dielectric polymers. The role of the counter-ion in determining the intrinsic and electroadhesive properties of poly(ethylene-co-acrylic acid) ionomers in bi- and tri-layered laminate structures was examined. PEAA ionomers were prepared with three tetraalkylammonium cations (NR4 +, R = methyl, TMA+; ethyl, TEA+; and propyl, TPA+). Reflecting the increasing hydrophobicity of the longer alkyl chains, water uptake changed as a function of counterion with TMA+ > TEA+ > TPA+. The glass transition temperatures, electrical resistivities, elastic moduli, and coefficients of friction were measured and found to depend on the cation identity. Overall, the cation-influenced mechanical properties of the ionomer determined the flexural rigidity range, but not the magnitude of the rigidity change, between the on and off states.

  19. The Education and Public Engagement (EPE) Component of the Ocean Observatories Initiative (OOI): Enabling Near Real-Time Data Use in Undergraduate Classrooms

    NASA Astrophysics Data System (ADS)

    Glenn, S. M.; Companion, C.; Crowley, M.; deCharon, A.; Fundis, A. T.; Kilb, D. L.; Levenson, S.; Lichtenwalner, C. S.; McCurdy, A.; McDonnell, J. D.; Overoye, D.; Risien, C. M.; Rude, A.; Wieclawek, J., III

    2011-12-01

    The National Science Foundation's Ocean Observatories Initiative (OOI) is constructing observational and computer infrastructure that will provide sustained ocean measurements to study climate variability, ocean circulation, ecosystem dynamics, air-sea exchange, seafloor processes, and plate-scale geodynamics over the next ~25-30 years. To accomplish this, the Consortium for Ocean Leadership established four Implementing Organizations: (1) Regional Scale Nodes; (2) Coastal and Global Scale Nodes; (3) Cyberinfrastructure (CI); and (4) Education and Public Engagement (EPE). The EPE, which we represent, was just recently established to provide a new layer of cyber-interactivity for educators to bring near real-time data, images and videos of our Earth's oceans into their learning environments. Our focus over the next four years is engaging educators of undergraduates and free-choice learners. Demonstration projects of the OOI capabilities will use an Integrated Education Toolkit to access OOI data through the Cyberinfrastructure's On Demand Measurement Processing capability. We will present our plans to develop six education infrastructure software modules: Education Web Services (middleware), Visualization Tools, Concept Map and Lab/Lesson Builders, Collaboration Tools, and an Education Resources Database. The software release of these tools is staggered to coincide with other major OOI releases. The first release will include stand-alone versions of the first four EPE modules (Fall 2012). Next, all six EPE modules will be integrated within the OOI cyber-framework (Fall 2013). The last release will include advanced capabilities for all six modules within a collaborative network that leverages the CI's Integrated Observatory Network (Fall 2014). We are looking for undergraduate and informal science educators to provide feedback and guidance on the project, please contact us if you are interested in partnering with us.

  20. Comparing soil carbon loss through respiration and leaching under extreme precipitation events in arid and semiarid grasslands

    NASA Astrophysics Data System (ADS)

    Liu, Ting; Wang, Liang; Feng, Xiaojuan; Zhang, Jinbo; Ma, Tian; Wang, Xin; Liu, Zongguang

    2018-03-01

    Respiration and leaching are two main processes responsible for soil carbon loss. While the former has received considerable research attention, studies examining leaching processes are limited, especially in semiarid grasslands due to low precipitation. Climate change may increase the extreme precipitation event (EPE) frequency in arid and semiarid regions, potentially enhancing soil carbon loss through leaching and respiration. Here we incubated soil columns of three typical grassland soils from Inner Mongolia and the Qinghai-Tibetan Plateau and examined the effect of simulated EPEs on soil carbon loss through respiration and leaching. EPEs induced a transient increase in CO2 release through soil respiration, equivalent to 32 and 72 % of the net ecosystem productivity (NEP) in the temperate grasslands (Xilinhot and Keqi) and 7 % of NEP in the alpine grasslands (Gangcha). By comparison, leaching loss of soil carbon accounted for 290, 120, and 15 % of NEP at the corresponding sites, respectively, with dissolved inorganic carbon (DIC, biogenic DIC + lithogenic DIC) as the main form of carbon loss in the alkaline soils. Moreover, DIC loss increased with recurring EPEs in the soil with the highest pH due to an elevated contribution of dissolved CO2 from organic carbon degradation (indicated by DIC-δ13C). These results highlight the fact that leaching loss of soil carbon (particularly in the form of DIC) is important in the regional carbon budget of arid and semiarid grasslands and also imply that SOC mineralization in alkaline soils might be underestimated if only measured as CO2 emission from soils into the atmosphere. With a projected increase in EPEs under climate change, soil carbon leaching processes and the influencing factors warrant a better understanding and should be incorporated into soil carbon models when estimating carbon balance in grassland ecosystems.

  1. CTX-M-15-non-ST131 Escherichia coli isolates are mainly responsible of faecal carriage with ESBL-producing Enterobacteriaceae in travellers, immigrants and those visiting friends and relatives.

    PubMed

    Valverde, A; Turrientes, M-C; Norman, F; San Martín, E; Moreno, L; Pérez-Molina, J A; López-Vélez, R; Cantón, R

    2015-03-01

    Prevalence of extended-spectrum β-lactamases (ESBL) and/or carbapenemase-producing Enterobacteriaceae (EPE and CPE) in stool samples from 75 travellers, 8 people visiting friends and relatives and 3 immigrants who had travelled or came from tropical or subtropical areas was determined. Thirty-one per cent (27/86) of the subjects were faecal carriers of EPE, and 37 EPE isolates were recovered (36 Escherichia coli, 1 Klebsiella pneumoniae). CTX-M-15 was the most prevalent enzyme (64.8%) mainly associated with E. coli belonging to phylogroup A and sequence type complex 10. Most of the ESBL-positive travellers (50%) had visited countries from Asia. Copyright © 2014 European Society of Clinical Microbiology and Infectious Diseases. Published by Elsevier Ltd. All rights reserved.

  2. Decision curve analysis to compare 3 versions of Partin Tables to predict final pathologic stage.

    PubMed

    Augustin, Herbert; Sun, Maxine; Isbarn, Hendrik; Pummer, Karl; Karakiewicz, Pierre

    2012-01-01

    To perform a decision curve analysis (DCA) to compare the Partin Tables 1997, 2001, and 2007 for their clinical applicability. Clinical and pathologic data of 687 consecutive patients treated with open radical prostatectomy for clinically localized prostate cancer between 2003 and 2008 at a single institution were used. DCA quantified the net benefit relating to specific threshold probabilities of extraprostatic extension (EPE), seminal vesicle involvement (SVI), and lymph node involvement (LNI). Overall, EPE, SVI, and LNI were recorded in 17.8, 6.0, and 1.2%, respectively. For EPE predictions, the DCA favored the 2007 version vs. 1997 for SVI vs. none of the versions for LNI. DCA indicate that for very low prevalence conditions such as LNI (1.2%), decision models are not useful. For low prevalence rates such as SVI, the use of different versions of the Partin Tables does not translate into meaningful net gains differences. Finally, for intermediate prevalence conditions such as EPE (18%), despite apparent performance differences, the net benefit differences were also marginal. In consequence, the current analysis could not confirm an important benefit from the use of the Partin Tables and it could not identify a clearly better version of any of the 3 available iterations. Copyright © 2012 Elsevier Inc. All rights reserved.

  3. Measured vs. Predicted Pedestal Pressure During RMP ELM Control in DIII-D

    NASA Astrophysics Data System (ADS)

    Zywicki, Bailey; Fenstermacher, Max; Groebner, Richard; Meneghini, Orso

    2017-10-01

    From database analysis of DIII-D plasmas with Resonant Magnetic Perturbations (RMPs) for ELM control, we will compare the experimental pedestal pressure (p_ped) to EPED code predictions and present the dependence of any p_ped differences from EPED on RMP parameters not included in the EPED model e.g. RMP field strength, toroidal and poloidal spectrum etc. The EPED code, based on Peeling-Ballooning and Kinetic Ballooning instability constraints, will also be used by ITER to predict the H-mode p_ped without RMPs. ITER plans to use RMPs as an effective ELM control method. The need to control ELMs in ITER is of the utmost priority, as it directly correlates to the lifetime of the plasma facing components. An accurate means of determining the impact of RMP ELM control on the p_ped is needed, because the device fusion power is strongly dependent on p_ped. With this new collection of data, we aim to provide guidance to predictions of the ITER pedestal during RMP ELM control that can be incorporated in a future predictive code. Work supported in part by US DoE under the Science Undergraduate Laboratory Internship (SULI) program and under DE-FC02-04ER54698, and DE-AC52-07NA27344.

  4. A parallel row-based algorithm with error control for standard-cell replacement on a hypercube multiprocessor

    NASA Technical Reports Server (NTRS)

    Sargent, Jeff Scott

    1988-01-01

    A new row-based parallel algorithm for standard-cell placement targeted for execution on a hypercube multiprocessor is presented. Key features of this implementation include a dynamic simulated-annealing schedule, row-partitioning of the VLSI chip image, and two novel new approaches to controlling error in parallel cell-placement algorithms; Heuristic Cell-Coloring and Adaptive (Parallel Move) Sequence Control. Heuristic Cell-Coloring identifies sets of noninteracting cells that can be moved repeatedly, and in parallel, with no buildup of error in the placement cost. Adaptive Sequence Control allows multiple parallel cell moves to take place between global cell-position updates. This feedback mechanism is based on an error bound derived analytically from the traditional annealing move-acceptance profile. Placement results are presented for real industry circuits and the performance is summarized of an implementation on the Intel iPSC/2 Hypercube. The runtime of this algorithm is 5 to 16 times faster than a previous program developed for the Hypercube, while producing equivalent quality placement. An integrated place and route program for the Intel iPSC/2 Hypercube is currently being developed.

  5. MRI-guided prostate focal laser ablation therapy using a mechatronic needle guidance system

    NASA Astrophysics Data System (ADS)

    Cepek, Jeremy; Lindner, Uri; Ghai, Sangeet; Davidson, Sean R. H.; Trachtenberg, John; Fenster, Aaron

    2014-03-01

    Focal therapy of localized prostate cancer is receiving increased attention due to its potential for providing effective cancer control in select patients with minimal treatment-related side effects. Magnetic resonance imaging (MRI)-guided focal laser ablation (FLA) therapy is an attractive modality for such an approach. In FLA therapy, accurate placement of laser fibers is critical to ensuring that the full target volume is ablated. In practice, error in needle placement is invariably present due to pre- to intra-procedure image registration error, needle deflection, prostate motion, and variability in interventionalist skill. In addition, some of these sources of error are difficult to control, since the available workspace and patient positions are restricted within a clinical MRI bore. In an attempt to take full advantage of the utility of intraprocedure MRI, while minimizing error in needle placement, we developed an MRI-compatible mechatronic system for guiding needles to the prostate for FLA therapy. The system has been used to place interstitial catheters for MRI-guided FLA therapy in eight subjects in an ongoing Phase I/II clinical trial. Data from these cases has provided quantification of the level of uncertainty in needle placement error. To relate needle placement error to clinical outcome, we developed a model for predicting the probability of achieving complete focal target ablation for a family of parameterized treatment plans. Results from this work have enabled the specification of evidence-based selection criteria for the maximum target size that can be confidently ablated using this technique, and quantify the benefit that may be gained with improvements in needle placement accuracy.

  6. The Effect of Microphone Placement on Interaural Level Differences and Sound Localization Across the Horizontal Plane in Bilateral Cochlear Implant Users.

    PubMed

    Jones, Heath G; Kan, Alan; Litovsky, Ruth Y

    2016-01-01

    This study examined the effect of microphone placement on the interaural level differences (ILDs) available to bilateral cochlear implant (BiCI) users, and the subsequent effects on horizontal-plane sound localization. Virtual acoustic stimuli for sound localization testing were created individually for eight BiCI users by making acoustic transfer function measurements for microphones placed in the ear (ITE), behind the ear (BTE), and on the shoulders (SHD). The ILDs across source locations were calculated for each placement to analyze their effect on sound localization performance. Sound localization was tested using a repeated-measures, within-participant design for the three microphone placements. The ITE microphone placement provided significantly larger ILDs compared to BTE and SHD placements, which correlated with overall localization errors. However, differences in localization errors across the microphone conditions were small. The BTE microphones worn by many BiCI users in everyday life do not capture the full range of acoustic ILDs available, and also reduce the change in cue magnitudes for sound sources across the horizontal plane. Acute testing with an ITE placement reduced sound localization errors along the horizontal plane compared to the other placements in some patients. Larger improvements may be observed if patients had more experience with the new ILD cues provided by an ITE placement.

  7. Effects of a Six-Week Strength Training Programme on Change of Direction Performance in Youth Team Sport Athletes

    PubMed Central

    Bourgeois, Frank A.; Gamble, Paul; Gill, Nic D.; McGuigan, Mike R.

    2017-01-01

    This study investigated the effects of eccentric phase-emphasis strength training (EPE) on unilateral strength and performance in 180- and 45-degree change of direction (COD) tasks in rugby union players. A 12-week cross-over design was used to compare the efficacy of resistance training executed with 3 s eccentric duration (EPE, n = 12) against conventional strength training, with no constraints on tempo (CON, n = 6). Players in each condition were categorised as ‘fast’ (FAST) or ‘slow’ (SLOW) using median trial times from baseline testing. Players recorded greater isometric strength improvements following EPE (ES = −0.54 to 1.80). Whilst these changes were not immediate, players improved in strength following cessation. Improvements in 180-degree COD performance was recorded at all test-points following EPE (ES = −1.32 to −0.15). Improvements in 45-degree COD performance were apparent for FAST following CON (ES = −0.96 to 0.10), but CON was deleterious for SLOW (ES = −0.60 to 1.53). Eccentric phase-emphasis strength training shows potential for sustained strength enhancement. Positive performance changes in COD tasks were category- and condition-specific. The data indicate the greatest improvement occurred at nine weeks following resistance training in these players. Performance benefits may also be specific to COD task, player category, and relative to emphasis on eccentric phase activity. PMID:29910443

  8. Foot placement during error and pedal applications in naturalistic driving.

    PubMed

    Wu, Yuqing; Boyle, Linda Ng; McGehee, Daniel; Roe, Cheryl A; Ebe, Kazutoshi; Foley, James

    2017-02-01

    Data from a naturalistic driving study was used to examine foot placement during routine foot pedal movements and possible pedal misapplications. The study included four weeks of observations from 30 drivers, where pedal responses were recorded and categorized. The foot movements associated with pedal misapplications and errors were the focus of the analyses. A random forest algorithm was used to predict the pedal application types based the video observations, foot placements, drivers' characteristics, drivers' cognitive function levels and anthropometric measurements. A repeated multinomial logit model was then used to estimate the likelihood of the foot placement given various driver characteristics and driving scenarios. The findings showed that prior foot location, the drivers' seat position, and the drive sequence were all associated with incorrect foot placement during an event. The study showed that there is a potential to develop a driver assistance system that can reduce the likelihood of a pedal error. Copyright © 2016 Elsevier Ltd. All rights reserved.

  9. The Relationship Between Technical Errors and Decision Making Skills in the Junior Resident

    PubMed Central

    Nathwani, J. N.; Fiers, R.M.; Ray, R.D.; Witt, A.K.; Law, K. E.; DiMarco, S.M.; Pugh, C.M.

    2017-01-01

    Objective The purpose of this study is to co-evaluate resident technical errors and decision-making capabilities during placement of a subclavian central venous catheter (CVC). We hypothesize that there will be significant correlations between scenario based decision making skills, and technical proficiency in central line insertion. We also predict residents will have problems in anticipating common difficulties and generating solutions associated with line placement. Design Participants were asked to insert a subclavian central line on a simulator. After completion, residents were presented with a real life patient photograph depicting CVC placement and asked to anticipate difficulties and generate solutions. Error rates were analyzed using chi-square tests and a 5% expected error rate. Correlations were sought by comparing technical errors and scenario based decision making. Setting This study was carried out at seven tertiary care centers. Participants Study participants (N=46) consisted of largely first year research residents that could be followed longitudinally. Second year research and clinical residents were not excluded. Results Six checklist errors were committed more often than anticipated. Residents performed an average of 1.9 errors, significantly more than the 1 error, at most, per person expected (t(44)=3.82, p<.001). The most common error was performance of the procedure steps in the wrong order (28.5%, P<.001). Some of the residents (24%) had no errors, 30% committed one error, and 46 % committed more than one error. The number of technical errors committed negatively correlated with the total number of commonly identified difficulties and generated solutions (r(33)= −.429, p=.021, r(33)= −.383, p=.044 respectively). Conclusions Almost half of the surgical residents committed multiple errors while performing subclavian CVC placement. The correlation between technical errors and decision making skills suggests a critical need to train residents in both technique and error management. ACGME Competencies Medical Knowledge, Practice Based Learning and Improvement, Systems Based Practice PMID:27671618

  10. Mathematics Course Placement Using Holistic Measures: Possibilities for Community College Students

    ERIC Educational Resources Information Center

    Ngo, Federick; Chi, W. Edward; Park, Elizabeth So Yun

    2018-01-01

    Background/Context: Most community colleges across the country use a placement test to determine students' readiness for college-level coursework, yet these tests are admittedly imperfect instruments. Researchers have documented significant problems stemming from overreliance on placement testing, including placement error and misdiagnosis of…

  11. Proceedings of the Workshop on Aquatic Ecosystem Modeling and Assessment Techniques for Application within the U.S. Army Corps of Engineers.

    DTIC Science & Technology

    1998-04-01

    Dr. Kennedy. Others who contributed directly to planning for the workshop included Drs. Todd S. Bridges, Mark S. Dortch, John M. Nestler, and...Quality and Contaminants Modeling Branch, EPED; Dr. Price, Chief, EPED; and Dr. John Harrison, Director, EL. At the time of the publication of this...this project is characterized by broad multi- agency interest and involvement, including several USACE Districts (St Paul , Rock Island, St, Louis

  12. Study of 1s internal bremsstrahlung spectrum from 57Co

    NASA Astrophysics Data System (ADS)

    Raghavendra, M. K.; Azeez, Syed; Ramaswamy, C. R.; Umesh, T. K.; Gowda, Ramakrishna

    2002-07-01

    The internal bremsstrahlung contribution from the electron capture of 57Co has been measured in coincidence with K-X-ray of the residual atom. The end-point energy (EPE) is extracted from the data using the linearised Jauch plot. The transition energy obtained using the (EPE) is 842.7 keV, which is close to the value given by Audi and Wapstra. The measured intensity and shape factor from 300 to 600 keV are found to be in good agreement with the Glauber and Martin theory.

  13. An exercise protocol designed to control energy expenditure for long-term space missions.

    PubMed

    Matsuo, Tomoaki; Ohkawara, Kazunori; Seino, Satoshi; Shimojo, Nobutake; Yamada, Shin; Ohshima, Hiroshi; Tanaka, Kiyoji; Mukai, Chiaki

    2012-08-01

    Astronauts experience weight loss during spaceflight. Future space missions require a more efficient exercise program not only to maintain work efficiency, but also to control increased energy expenditure (EE). When discussing issues concerning EE incurred through exercise, excess post-exercise energy expenditure (EPEE) must also be considered. The aim of this study was to compare the total EE, including EPEE, induced by two types of interval cycling protocols with the total EE of a traditional, continuous cycling protocol. There were 10 healthy men, ages 20 to 31 yr, who completed 3 exercise sessions: sprint interval training (SIT) consisting of 7 sets of 30-s cycling at 120% VO2max with a 15-s rest between each bout; high-intensity interval aerobic training (HIAT) consisting of 3 sets of 3-min cycling at 80-90% VO2max with a 2-min active rest at 50% VO2max; and continuous aerobic training (CAT) consisting of 40 min of cycling at 60-65% VO2max. During each session, resting metabolic rate, exercise EE, and a 180-min post-exercise EE were measured. The EPEEs during the SIT, HIAT, and CAT averaged 32 +/- 19, 21 +/- 16, and 13 +/- 13 kcal, and the total EE for an entire exercise/ rest session averaged 109 +/- 20, 182 +/- 17, and 363 +/- 45 kcal, respectively. While the EPEE after the CAT was significantly less than after the SIT, the total EE with the CAT was the greatest of the three. The SIT and HIAT would be potential protocols to control energy expenditure for long space missions.

  14. Analysis of hydrocarbons generated in coalbeds

    NASA Astrophysics Data System (ADS)

    Butala, Steven John M.

    This dissertation describes kinetic calculations using literature data to predict formation rates and product yields of oil and gas at typical low-temperature conditions in coalbeds. These data indicate that gas formation rates from hydrocarbon thermolysis are too low to have generated commercial quantities of natural gas, assuming bulk first-order kinetics. Acid-mineral-catalyzed cracking, transition-metal-catalyzed hydrogenolysis of liquid hydrocarbons, and catalyzed CO2 hydrogenation form gas at high rates. The gaseous product compositions for these reactions are nearly the same as those for typical natural coalbed gases, while those from thermal and catalytic cracking are more representative of atypical coalbed gases. Three Argonne Premium Coals (Upper-Freeport, Pittsburgh #8 and Lewiston-Stockton) were extracted with benzene in both Soxhlet and elevated pressure extraction (EPE) systems. The extracts were compared on the basis of dry mass yield and hydrocarbon profiles obtained by gas chromatography/mass spectrometry. The dry mass yields for the Upper-Freeport coal gave consistent results by both methods, while the yields from the Pittsburgh #8 and Lewiston-Stockton coals were greater by the EPE method. EPE required ˜90 vol. % less solvent compared to Soxhlet extraction. Single-ion-chromatograms of the Soxhlet extracts all exhibited bimodal distributions, while those of the EPE extracts did not. Hydrocarbons analyzed from Greater Green River Basin samples indicate that the natural oils in the basin originated from the coal seams. Analysis of artificially produced oil indicates that hydrous pyrolysis mimics generation of C15+ n-alkanes, but significant variations were found in the branched alkane, low-molecular-weight n-alkanes, and high-molecular-weight aromatic hydrocarbon distributions.

  15. Surface studies of praseodymium by electron spectroscopies

    NASA Astrophysics Data System (ADS)

    Krawczyk, Mirosław; Pisarek, Marcin; Lisowski, Wojciech; Jablonski, Aleksander

    2016-12-01

    Electron transport properties in praseodymium (Pr) foil samples were studied by elastic-peak electron spectroscopy (EPES). Prior to EPES measurements, the Pr sample surface was pre-sputtered by Ar ions with ion energy of 2-3 keV. After such treatment, the Pr sample still contained about 10 at.% of residual oxygen in the surface region, as detected by X-ray photoelectron spectroscopy (XPS) and Auger electron spectroscopy (AES) analyses. The inelastic mean free path (IMFP), characterizing electron transport within this region (4 nm-thick), was evaluated from EPES using both Ni and Au standards as a function of energy in the range of 0.5-2 keV. Experimental IMFPs, λ, were approximated by the simple function λ = kEp, where E is energy (in eV), and k = 0.1549 and p = 0.7047 were the fitted parameters. These values were compared with IMFPs for the praseodymium surface in which the presence of oxygen was tentatively neglected, and also with IMFPs resulting from the TPP-2M predictive equation for bulk praseodymium. We found that the measured IMFP values to be only slightly affected by neglect of oxygen in calculations. The fitted function applied here was consistent with the energy dependence of the EPES-measured IMFPs. Additionally, the measured IMFPs were found to be from 2% to 4.2% larger than the predicted IMFPs for praseodymium in the energy range of 500-1000 eV. For electron energies of 1500 eV and 2000 eV, there was an inverse correlation between these values, and then the resulting deviations of -0.4% and -2.7%, respectively, were calculated.

  16. Package Design Affects Accuracy Recognition for Medications.

    PubMed

    Endestad, Tor; Wortinger, Laura A; Madsen, Steinar; Hortemo, Sigurd

    2016-12-01

    Our aim was to test if highlighting and placement of substance name on medication package have the potential to reduce patient errors. An unintentional overdose of medication is a large health issue that might be linked to medication package design. In two experiments, placement, background color, and the active ingredient of generic medication packages were manipulated according to best human factors guidelines to reduce causes of labeling-related patient errors. In two experiments, we compared the original packaging with packages where we varied placement of the name, dose, and background of the active ingredient. Age-relevant differences and the effect of color on medication recognition error were tested. In Experiment 1, 59 volunteers (30 elderly and 29 young students), participated. In Experiment 2, 25 volunteers participated. The most common error was the inability to identify that two different packages contained the same active ingredient (young, 41%, and elderly, 68%). This kind of error decreased with the redesigned packages (young, 8%, and elderly, 16%). Confusion errors related to color design were reduced by two thirds in the redesigned packages compared with original generic medications. Prominent placement of substance name and dose with a band of high-contrast color support recognition of the active substance in medications. A simple modification including highlighting and placing the name of the active ingredient in the upper right-hand corner of the package helps users realize that two different packages can contain the same active substance, thus reducing the risk of inadvertent medication overdose. © 2016, Human Factors and Ergonomics Society.

  17. Package Design Affects Accuracy Recognition for Medications

    PubMed Central

    Endestad, Tor; Wortinger, Laura A.; Madsen, Steinar; Hortemo, Sigurd

    2016-01-01

    Objective: Our aim was to test if highlighting and placement of substance name on medication package have the potential to reduce patient errors. Background: An unintentional overdose of medication is a large health issue that might be linked to medication package design. In two experiments, placement, background color, and the active ingredient of generic medication packages were manipulated according to best human factors guidelines to reduce causes of labeling-related patient errors. Method: In two experiments, we compared the original packaging with packages where we varied placement of the name, dose, and background of the active ingredient. Age-relevant differences and the effect of color on medication recognition error were tested. In Experiment 1, 59 volunteers (30 elderly and 29 young students), participated. In Experiment 2, 25 volunteers participated. Results: The most common error was the inability to identify that two different packages contained the same active ingredient (young, 41%, and elderly, 68%). This kind of error decreased with the redesigned packages (young, 8%, and elderly, 16%). Confusion errors related to color design were reduced by two thirds in the redesigned packages compared with original generic medications. Conclusion: Prominent placement of substance name and dose with a band of high-contrast color support recognition of the active substance in medications. Application: A simple modification including highlighting and placing the name of the active ingredient in the upper right-hand corner of the package helps users realize that two different packages can contain the same active substance, thus reducing the risk of inadvertent medication overdose. PMID:27591209

  18. Pattern placement errors: application of in-situ interferometer-determined Zernike coefficients in determining printed image deviations

    NASA Astrophysics Data System (ADS)

    Roberts, William R.; Gould, Christopher J.; Smith, Adlai H.; Rebitz, Ken

    2000-08-01

    Several ideas have recently been presented which attempt to measure and predict lens aberrations for new low k1 imaging systems. Abbreviated sets of Zernike coefficients have been produced and used to predict Across Chip Linewidth Variation. Empirical use of the wavefront aberrations can now be used in commercially available lithography simulators to predict pattern distortion and placement errors. Measurement and Determination of Zernike coefficients has been a significant effort of many. However the use of this data has generally been limited to matching lenses or picking best fit lense pairs. We will use wavefront aberration data collected using the Litel InspecStep in-situ Interferometer as input data for Prolith/3D to model and predict pattern placement errors and intrafield overlay variation. Experiment data will be collected and compared to the simulated predictions.

  19. Faecal carriage of CTX-M extended-spectrum beta-lactamase-producing Enterobacteriaceae among street children dwelling in Mwanza city, Tanzania.

    PubMed

    Moremi, Nyambura; Claus, Heike; Vogel, Ulrich; Mshana, Stephen E

    2017-01-01

    Data on ESBL carriage of healthy people including children are scarce especially in developing countries. We analyzed the prevalence and genotypes of ESBL-producing Enterobacteriaceae (EPE) in Tanzanian street children with rare contact to healthcare facilities but significant interactions with the environment, animals and other people. Between April and July 2015, stool samples of 107 street children, who live in urban Mwanza were analyzed for EPE. Intestinal carriage of EPE was found in 34 (31.8%, 95% CI; 22.7-40.3) children. Of the 36 isolates from 34 children, 30 (83.3%) were Escherichia coli (E. coli) and six Klebsiella pneumoniae (K. pneumoniae). Out of 36 isolates, 36 (100%), 35 (97%), 25 (69%) and 16 (44%) were resistant to tetracycline, trimethoprim-sulfamethoxazole, ciprofloxacin and gentamicin, respectively. Beta-lactamase genes and the multilocus sequence types of E. coli and K. pneumoniae were characterized. ESBL gene blaCTX-M-15 was detected in 75% (27/36) of ESBL isolates. Sequence types (STs) 131, 10, 448 and 617 were the most prevalent in E. coli. Use of local herbs (OR: 3.5, 95% CI: 1.51-8.08, P = 0.003) and spending day and night on streets (OR: 3.6, 95% CI: 1.44-8.97, P = 0.005) were independent predictors of ESBL carriage. We observed a high prevalence of blaCTX-M-15 in EPE collected from street children in Tanzania. Detection of E. coli STs 131, 10, 38 and 648, which have been observed worldwide in animals and people, highlights the need for multidisciplinary approaches to understand the epidemiology and drivers of antimicrobial resistance in low-income countries.

  20. Does the Prostate Imaging-Reporting and Data System (PI-RADS) version 2 improve accuracy in reporting anterior lesions on multiparametric magnetic resonance imaging (mpMRI)?

    PubMed

    Hoffmann, Richard; Logan, Callum; O'Callaghan, Michael; Gormly, Kirsten; Chan, Ken; Foreman, Darren

    2018-01-01

    Multiparametric MRI (mpMRI) is useful in detecting anterior prostate tumours. Due to the location of anterior tumours, they are often diagnosed with a large size and may be suspicious for extra-prostatic extension (EPE). We aim to evaluate whether PI-RADS v2 is more accurate in assessing anterior prostate lesions identified on mpMRI compared to PI-RADS v1. Patients with anterior prostate lesions diagnosed on mpMRI who proceeded to a cognitive fusion transperineal prostate biopsy were identified. Each mpMRI was blinded and read by two experienced prostate MRI radiologists and assigned a PI-RADS v1 and PI-RADS v2 score, and the presence of EPE was estimated. Correlation was made with transperineal histopathology and, where relevant, radical prostatectomy histopathology. Concordance measures between PI-RADS v1 and PI-RADS v2, and between examiners of the same PI-RADS score were calculated using a weighted kappa. Fifty-eight consecutive men were identified. Concordance between the examiners for PI-RADS v1 and for v2 showed substantial agreement (version 1: weighted kappa 0.71; version 2: weighted kappa 0.69). There was no difference in accuracy when using PI-RADS v1 or PI-RADS v2 to predict clinically significant cancer. There was poor correlation between EPE measured on mpMRI compared with EPE in radical prostatectomy histopathology. PI-RADS v2 is reproducible between radiologists but does not have improved accuracy for diagnosing anterior tumours of the prostate when compared to PI-RADS v1. Multiparametric MRI is accurate at detecting anterior tumours with a sensitivity of 86-88%.

  1. Multiparametric Magnetic-Resonance to Confirm Eligibility to an Active Surveillance Program for Low-Risk Prostate Cancer: Intermediate Time Results of a Third Referral High Volume Centre Active Surveillance Protocol.

    PubMed

    Luzzago, Stefano; Musi, Gennaro; Catellani, Michele; Russo, Andrea; Di Trapani, Ettore; Mistretta, Francesco Alessandro; Bianchi, Roberto; Cozzi, Gabriele; Conti, Andrea; Pricolo, Paola; Ferro, Matteo; Matei, Deliu-Victor; Mirone, Vincenzo; Petralia, Giuseppe; de Cobelli, Ottavio

    2018-05-07

    To evaluate the role of confirmatory multiparametric magnetic resonance imaging (mpMRI) of the prostate at the time of Active Surveillance (AS) enrollment to reduce disease misclassification. From 2012 to 2016, 383 patients with low-risk disease respecting Prostate Cancer Research International AS criteria underwent confirmatory 1.5-T mpMRI. AS was proposed to patients with Prostate Imaging and Report and Data System (PI-RADS) score ≤3 and no extraprostatic extension (EPE), whereas patients with PI-RADS score ≥4 and/or EPE were treated actively. Kaplan-Meier analyses quantified progression-free survival (PFS) in patients enrolled in the AS program. Logistic regression analyses tested the association between confirmatory mpMRI and clinically significant prostate cancer (csPCa) at radical prostatectomy (RP). Diagnostic performance of mpMRI was calculated in patients submitted to immediate RP. PFS rate was 99, 90 and 86% at 1, 2 and 3 years respectively. At multivariable analysis, PI-RADS 3, PI-RADS 4, PI-RADS 5 and EPE increased the probability of having csPCa at immediate RP (PI-RADS 3 [OR] 1.2, p = 0.26; PI-RADS 4 [OR] 5.1, p = 0.02; PI-RADS 5 [OR] 6.7; p = 0.009; EPE [OR] 11.8, p < 0.001). Confirmatory mpMRI showed sensibility, specificity, positive predictive value and negative predictive value of 85, 55, 68 and 76% respectively. MpMRI at the time of AS enrollment reduces the misclassification rate of csPCa. We suggest to perform target biopsies in patients with PI-RADS score 3 and 4 lesions. © 2018 S. Karger AG, Basel.

  2. Quick foot placement adjustments during gait are less accurate in individuals with focal cerebellar lesions.

    PubMed

    Hoogkamer, Wouter; Potocanac, Zrinka; Van Calenbergh, Frank; Duysens, Jacques

    2017-10-01

    Online gait corrections are frequently used to restore gait stability and prevent falling. They require shorter response times than voluntary movements which suggests that subcortical pathways contribute to the execution of online gait corrections. To evaluate the potential role of the cerebellum in these pathways we tested the hypotheses that online gait corrections would be less accurate in individuals with focal cerebellar damage than in neurologically intact controls and that this difference would be more pronounced for shorter available response times and for short step gait corrections. We projected virtual stepping stones on an instrumented treadmill while some of the approaching stepping stones were shifted forward or backward, requiring participants to adjust their foot placement. Varying the timing of those shifts allowed us to address the effect of available response time on foot placement error. In agreement with our hypothesis, individuals with focal cerebellar lesions were less accurate in adjusting their foot placement in reaction to suddenly shifted stepping stones than neurologically intact controls. However, the cerebellar lesion group's foot placement error did not increase more with decreasing available response distance or for short step versus long step adjustments compared to the control group. Furthermore, foot placement error for the non-shifting stepping stones was also larger in the cerebellar lesion group as compared to the control group. Consequently, the reduced ability to accurately adjust foot placement during walking in individuals with focal cerebellar lesions appears to be a general movement control deficit, which could contribute to increased fall risk. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Perception of Place of Articulation by Children with Cleft Palate and Posterior Placement.

    ERIC Educational Resources Information Center

    Whitehill, Tara L.; Francis, Alexander L.; Ching, Christine K-Y.

    2003-01-01

    A study examined if 10 children (ages 4-12) with repaired cleft palate who demonstrate posterior placement of alveolar targets differed from 10 children with cleft palate without such error patterns, and from 10 controls in the perception of alveolar targets. Children with posterior placement appeared unable to distinguish alveolar targets.…

  4. A Blueprint of Pain Curriculum across Prelicensure Health Sciences Programs: One NIH Pain Consortium Center of Excellence in Pain Education (CoEPE) Experience

    PubMed Central

    Doorenbos, AZ; Gordon, DB; Tauben, D; Palisoc, J; Drangsholt, M; Lindhorst, T; Danielson, J; Spector, J; Ballweg, R; Vorvick, L; Loeser, JD

    2013-01-01

    To improve U.S. pain education and promote inter-institutional and inter-professional collaborations, the NIH Pain Consortium has funded 12 sites to develop Centers of Excellence in Pain Education (CoEPE). Each site was given the tasks of development, evaluation, integration, and promotion of pain management curriculum resources, including case studies that will be shared nationally. Collaborations among schools of medicine, dentistry, nursing, pharmacy, and others were encouraged. The John D. Loeser CoEPE is unique in that it represents extensive regionalization of health science education, in this case in the region covering the states of Washington, Wyoming, Alaska, Montana, and Idaho (WWAMI). This paper describes a blueprint of pain content and teaching methods across the University of Washington’s six health sciences schools and provides recommendations for improvement in pain education at the prelicensure level. The Schools of Dentistry and Physician Assistant provide the highest percentage of total required curriculum hours devoted to pain compared with the Schools of Medicine, Nursing, Pharmacy, and Social Work. The findings confirm paucity of pain content in health sciences curricula, missing International Association for the Study of Pain (IASP) curriculum topics, and limited use of innovative teaching methods such as problem-based and team-based learning. PMID:24094694

  5. Super H-mode: theoretical prediction and initial observations of a new high performance regime for tokamak operation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Snyder, Philip B.; Solomon, Wayne M.; Burrell, Keith H.

    2015-07-21

    A new “Super H-mode” regime is predicted, which enables pedestal height and predicted fusion performance substantially higher than for H-mode operation. This new regime is predicted to exist by the EPED pedestal model, which calculates criticality constraints for peeling-ballooning and kinetic ballooning modes, and combines them to predict the pedestal height and width. EPED usually predicts a single (“H-mode”) pedestal solution for each set of input parameters, however, in strongly shaped plasmas above a critical density, multiple pedestal solutions are found, including the standard “Hmode” solution, and a “Super H-Mode” solution at substantially larger pedestal height and width. The Supermore » H-mode regime is predicted to be accessible by controlling the trajectory of the density, and to increase fusion performance for ITER, as well as for DEMO designs with strong shaping. A set of experiments on DIII-D has identified the predicted Super H-mode regime, and finds pedestal height and width, and their variation with density, in good agreement with theoretical predictions from the EPED model. Finally, the very high pedestal enables operation at high global beta and high confinement, including the highest normalized beta achieved on DIII-D with a quiescent edge.« less

  6. Atopic dermatitis increases the effect of exposure to peanut antigen in dust on peanut sensitization and likely peanut allergy

    PubMed Central

    Brough, Helen A.; Liu, Andrew H.; Sicherer, Scott; Makinson, Kerry; Douiri, Abdel; Brown, Sara J.; Stephens, Alick C.; Irwin McLean, W.H.; Turcanu, Victor; Wood, Robert A.; Jones, Stacie M.; Burks, Wesley; Dawson, Peter; Stablein, Donald; Sampson, Hugh; Lack, Gideon

    2015-01-01

    Background History and severity of atopic dermatitis (AD) are risk factors for peanut allergy. Recent evidence suggests that children can become sensitized to food allergens through an impaired skin barrier. Household peanut consumption, which correlates strongly with peanut protein levels in household dust, is a risk factor for peanut allergy. Objective We sought to assess whether environmental peanut exposure (EPE) is a risk for peanut sensitization and allergy and whether markers of an impaired skin barrier modify this risk. Methods Peanut protein in household dust (in micrograms per gram) was assessed in highly atopic children (age, 3-15 months) recruited to the Consortium of Food Allergy Research Observational Study. History and severity of AD, peanut sensitization, and likely allergy (peanut-specific IgE, ≥5 kUA/mL) were assessed at recruitment into the Consortium of Food Allergy Research study. Results There was an exposure-response relationship between peanut protein levels in household dust and peanut skin prick test (SPT) sensitization and likely allergy. In the final multivariate model an increase in 4 log2 EPE units increased the odds of peanut SPT sensitization (1.71-fold; 95% CI, 1.13- to 2.59-fold; P = .01) and likely peanut allergy (PA; 2.10-fold; 95% CI, 1.20- to 3.67-fold; P < .01). The effect of EPE on peanut SPT sensitization was augmented in children with a history of AD (OR, 1.97; 95% CI, 1.26-3.09; P < .01) and augmented even further in children with a history of severe AD (OR, 2.41; 95% CI, 1.30-4.47; P < .01); the effect of EPE on PA was also augmented in children with a history of AD (OR, 2.34; 95% CI, 1.31-4.18; P < .01). Conclusion Exposure to peanut antigen in dust through an impaired skin barrier in atopically inflamed skin is a plausible route for peanut SPT sensitization and PA. PMID:25457149

  7. Lawsonia intracellularis in the feces of wild rodents and stray cats captured around equine farms.

    PubMed

    Hwang, Jeong-Min; Seo, Myung-Ji; Yeh, Jung-Yong

    2017-08-11

    Proliferative enteropathy is a global enteric disease of particular importance in pigs. The causative bacterium, Lawsonia intracellularis, has a wide range of susceptible host species. Recently, L. intracellularis has been recognized as an etiologic agent of an emerging enteric disease in foals called equine proliferative enteropathy (EPE). The presence of L. intracellularis in nonruminant wildlife has raised questions regarding the role of these species in EPE transmission. This study investigated exposure to L. intracellularis in wild rodents and feral cats from eight farms with confirmed EPE. Serum (42) and fecal (40) samples from resident foals and fecal samples (131), intestinal mucosa tissues (14), and mesenteric lymph nodes (14) from wild and feral animals were collected for the evaluation of the farm status and the molecular detection of L. intracellularis following the diagnosis of EPE in index cases. Fresh feces from wild rodents and feral cats were collected from the ground while walking the premises or after trapping the animals using live traps. A total of 3 brown rats, 7 house mice, 1 striped field mouse, 2 grey red-backed voles, and 3 feral cats showed evidence of prior exposure to L. intracellularis. Our data add to increasing evidence demonstrating the potential for L. intracellularis transmission and infection in wild rodents and feral cats and provide possible evidence of interspecies transmission. The exposure of wild rodents and feral cats provides potential evidence for the spillover of L. intracellularis to wildlife species and raises the question of spillback to horses. Additionally, these animals may represent an indicator of environmental exposure or may be actively involved in the transmission of L. intracellularis to foals by acting as potential reservoir/amplifier hosts. This study is the first to demonstrate the magnitude of L. intracellularis shedding in the feces of wild rodents and feral cats and to indicate the significant infection risk that wild rodents and feral cats pose to naïve horses in South Korea.

  8. Accuracy of frame-based stereotactic depth electrode implantation during craniotomy for subdural grid placement.

    PubMed

    Munyon, Charles N; Koubeissi, Mohamad Z; Syed, Tanvir U; Lüders, Hans O; Miller, Jonathan P

    2013-01-01

    Frame-based stereotaxy and open craniotomy may seem mutually exclusive, but invasive electrophysiological monitoring can require broad sampling of the cortex and precise targeting of deeper structures. The purpose of this study is to describe simultaneous frame-based insertion of depth electrodes and craniotomy for placement of subdural grids through a single surgical field and to determine the accuracy of depth electrodes placed using this technique. A total of 6 patients with intractable epilepsy underwent placement of a stereotactic frame with the center of the planned cranial flap equidistant from the fixation posts. After volumetric imaging, craniotomy for placement of subdural grids was performed. Depth electrodes were placed using frame-based stereotaxy. Postoperative CT determined the accuracy of electrode placement. A total of 31 depth electrodes were placed. Mean distance of distal electrode contact from the target was 1.0 ± 0.15 mm. Error was correlated to distance to target, with an additional 0.35 mm error for each centimeter (r = 0.635, p < 0.001); when corrected, there was no difference in accuracy based on target structure or method of placement (prior to craniotomy vs. through grid, p = 0.23). The described technique for craniotomy through a stereotactic frame allows placement of subdural grids and depth electrodes without sacrificing the accuracy of a frame or requiring staged procedures.

  9. Development of interactions between sensorimotor representations in school-aged children

    PubMed Central

    KAGERER, Florian A.; CLARK, Jane E.

    2014-01-01

    Reliable sensory-motor integration is a pre-requisite for optimal movement control; the functionality of this integration changes during development. Previous research has shown that motor performance of school-age children is characterized by higher variability, particularly under conditions where vision is not available, and movement planning and control is largely based on kinesthetic input. The purpose of the current study was to determine the characteristics of how kinesthetic-motor internal representations interact with visuo-motor representations during development. To this end, we induced a visuo-motor adaptation in 59 children, ranging from 5 to 12 years of age, as well as in a group of adults, and measured initial directional error (IDE) and endpoint error (EPE) during a subsequent condition where visual feedback was not available, and participants had to rely on kinesthetic input. Our results show that older children (age range 9–12 years) de-adapted significantly more than younger children (age range 5–8 years) over the course of 36 trials in the absence of vision, suggesting that the kinesthetic-motor internal representation in the older children was utilized more efficiently to guide hand movements, and was comparable to the performance of the adults. PMID:24636697

  10. Optimal accelerometer placement on a robot arm for pose estimation

    NASA Astrophysics Data System (ADS)

    Wijayasinghe, Indika B.; Sanford, Joseph D.; Abubakar, Shamsudeen; Saadatzi, Mohammad Nasser; Das, Sumit K.; Popa, Dan O.

    2017-05-01

    The performance of robots to carry out tasks depends in part on the sensor information they can utilize. Usually, robots are fitted with angle joint encoders that are used to estimate the position and orientation (or the pose) of its end-effector. However, there are numerous situations, such as in legged locomotion, mobile manipulation, or prosthetics, where such joint sensors may not be present at every, or any joint. In this paper we study the use of inertial sensors, in particular accelerometers, placed on the robot that can be used to estimate the robot pose. Studying accelerometer placement on a robot involves many parameters that affect the performance of the intended positioning task. Parameters such as the number of accelerometers, their size, geometric placement and Signal-to-Noise Ratio (SNR) are included in our study of their effects for robot pose estimation. Due to the ubiquitous availability of inexpensive accelerometers, we investigated pose estimation gains resulting from using increasingly large numbers of sensors. Monte-Carlo simulations are performed with a two-link robot arm to obtain the expected value of an estimation error metric for different accelerometer configurations, which are then compared for optimization. Results show that, with a fixed SNR model, the pose estimation error decreases with increasing number of accelerometers, whereas for a SNR model that scales inversely to the accelerometer footprint, the pose estimation error increases with the number of accelerometers. It is also shown that the optimal placement of the accelerometers depends on the method used for pose estimation. The findings suggest that an integration-based method favors placement of accelerometers at the extremities of the robot links, whereas a kinematic-constraints-based method favors a more uniformly distributed placement along the robot links.

  11. Seismo-acoustic ray model benchmarking against experimental tank data.

    PubMed

    Camargo Rodríguez, Orlando; Collis, Jon M; Simpson, Harry J; Ey, Emanuel; Schneiderwind, Joseph; Felisberto, Paulo

    2012-08-01

    Acoustic predictions of the recently developed traceo ray model, which accounts for bottom shear properties, are benchmarked against tank experimental data from the EPEE-1 and EPEE-2 (Elastic Parabolic Equation Experiment) experiments. Both experiments are representative of signal propagation in a Pekeris-like shallow-water waveguide over a non-flat isotropic elastic bottom, where significant interaction of the signal with the bottom can be expected. The benchmarks show, in particular, that the ray model can be as accurate as a parabolic approximation model benchmarked in similar conditions. The results of benchmarking are important, on one side, as a preliminary experimental validation of the model and, on the other side, demonstrates the reliability of the ray approach for seismo-acoustic applications.

  12. Virtual sensors for active noise control in acoustic-structural coupled enclosures using structural sensing: part II--Optimization of structural sensor placement.

    PubMed

    Halim, Dunant; Cheng, Li; Su, Zhongqing

    2011-04-01

    The work proposed an optimization approach for structural sensor placement to improve the performance of vibro-acoustic virtual sensor for active noise control applications. The vibro-acoustic virtual sensor was designed to estimate the interior sound pressure of an acoustic-structural coupled enclosure using structural sensors. A spectral-spatial performance metric was proposed, which was used to quantify the averaged structural sensor output energy of a vibro-acoustic system excited by a spatially varying point source. It was shown that (i) the overall virtual sensing error energy was contributed additively by the modal virtual sensing error and the measurement noise energy; (ii) each of the modal virtual sensing error system was contributed by both the modal observability levels for the structural sensing and the target acoustic virtual sensing; and further (iii) the strength of each modal observability level was influenced by the modal coupling and resonance frequencies of the associated uncoupled structural/cavity modes. An optimal design of structural sensor placement was proposed to achieve sufficiently high modal observability levels for certain important panel- and cavity-controlled modes. Numerical analysis on a panel-cavity system demonstrated the importance of structural sensor placement on virtual sensing and active noise control performance, particularly for cavity-controlled modes.

  13. A pilot study of the utility of a laboratory-based spinal fixation training program for neurosurgical residents.

    PubMed

    Sundar, Swetha J; Healy, Andrew T; Kshettry, Varun R; Mroz, Thomas E; Schlenk, Richard; Benzel, Edward C

    2016-05-01

    OBJECTIVE Pedicle and lateral mass screw placement is technically demanding due to complex 3D spinal anatomy that is not easily visualized. Neurosurgical and orthopedic surgery residents must be properly trained in such procedures, which can be associated with significant complications and associated morbidity. Current training in pedicle and lateral mass screw placement involves didactic teaching and supervised placement in the operating room. The objective of this study was to assess whether teaching residents to place pedicle and lateral mass screws using navigation software, combined with practice using cadaveric specimens and Sawbones models, would improve screw placement accuracy. METHODS This was a single-blinded, prospective, randomized pilot study with 8 junior neurosurgical residents and 2 senior medical students with prior neurosurgery exposure. Both the study group and the level of training-matched control group (each group with 4 level of training-matched residents and 1 senior medical student) were exposed to a standardized didactic education regarding spinal anatomy and screw placement techniques. The study group was exposed to an additional pilot program that included a training session using navigation software combined with cadaveric specimens and accessibility to Sawbones models. RESULTS A statistically significant reduction in overall surgical error was observed in the study group compared with the control group (p = 0.04). Analysis by spinal region demonstrated a significant reduction in surgical error in the thoracic and lumbar regions in the study group compared with controls (p = 0.02 and p = 0.04, respectively). The study group also was observed to place screws more optimally in the cervical, thoracic, and lumbar regions (p = 0.02, p = 0.04, and p = 0.04, respectively). CONCLUSIONS Surgical resident education in pedicle and lateral mass screw placement is a priority for training programs. This study demonstrated that compared with a didactic-only training model, using navigation simulation with cadavers and Sawbones models significantly reduced the number of screw placement errors in a laboratory setting.

  14. Synthesis of Arbitrary Quantum Circuits to Topological Assembly: Systematic, Online and Compact.

    PubMed

    Paler, Alexandru; Fowler, Austin G; Wille, Robert

    2017-09-05

    It is challenging to transform an arbitrary quantum circuit into a form protected by surface code quantum error correcting codes (a variant of topological quantum error correction), especially if the goal is to minimise overhead. One of the issues is the efficient placement of magic state distillation sub circuits, so-called distillation boxes, in the space-time volume that abstracts the computation's required resources. This work presents a general, systematic, online method for the synthesis of such circuits. Distillation box placement is controlled by so-called schedulers. The work introduces a greedy scheduler generating compact box placements. The implemented software, whose source code is available at www.github.com/alexandrupaler/tqec, is used to illustrate and discuss synthesis examples. Synthesis and optimisation improvements are proposed.

  15. Differential-Drive Mobile Robot Control Design based-on Linear Feedback Control Law

    NASA Astrophysics Data System (ADS)

    Nurmaini, Siti; Dewi, Kemala; Tutuko, Bambang

    2017-04-01

    This paper deals with the problem of how to control differential driven mobile robot with simple control law. When mobile robot moves from one position to another to achieve a position destination, it always produce some errors. Therefore, a mobile robot requires a certain control law to drive the robot’s movement to the position destination with a smallest possible error. In this paper, in order to reduce position error, a linear feedback control is proposed with pole placement approach to regulate the polynoms desired. The presented work leads to an improved understanding of differential-drive mobile robot (DDMR)-based kinematics equation, which will assist to design of suitable controllers for DDMR movement. The result show by using the linier feedback control method with pole placement approach the position error is reduced and fast convergence is achieved.

  16. POD-based constrained sensor placement and field reconstruction from noisy wind measurements: A perturbation study

    DOE PAGES

    Zhang, Zhongqiang; Yang, Xiu; Lin, Guang

    2016-04-14

    Sensor placement at the extrema of Proper Orthogonal Decomposition (POD) is efficient and leads to accurate reconstruction of the wind field from a limited number of measure- ments. In this paper we extend this approach of sensor placement and take into account measurement errors and detect possible malfunctioning sensors. We use the 48 hourly spa- tial wind field simulation data sets simulated using the Weather Research an Forecasting (WRF) model applied to the Maine Bay to evaluate the performances of our methods. Specifically, we use an exclusion disk strategy to distribute sensors when the extrema of POD modes are close.more » It turns out that this strategy can also reduce the error of recon- struction from noise measurements. Also, by a cross-validation technique, we successfully locate the malfunctioning sensors.« less

  17. Influence of model errors in optimal sensor placement

    NASA Astrophysics Data System (ADS)

    Vincenzi, Loris; Simonini, Laura

    2017-02-01

    The paper investigates the role of model errors and parametric uncertainties in optimal or near optimal sensor placements for structural health monitoring (SHM) and modal testing. The near optimal set of measurement locations is obtained by the Information Entropy theory; the results of placement process considerably depend on the so-called covariance matrix of prediction error as well as on the definition of the correlation function. A constant and an exponential correlation function depending on the distance between sensors are firstly assumed; then a proposal depending on both distance and modal vectors is presented. With reference to a simple case-study, the effect of model uncertainties on results is described and the reliability and the robustness of the proposed correlation function in the case of model errors are tested with reference to 2D and 3D benchmark case studies. A measure of the quality of the obtained sensor configuration is considered through the use of independent assessment criteria. In conclusion, the results obtained by applying the proposed procedure on a real 5-spans steel footbridge are described. The proposed method also allows to better estimate higher modes when the number of sensors is greater than the number of modes of interest. In addition, the results show a smaller variation in the sensor position when uncertainties occur.

  18. Common Algorithms of Primary Stress Placement on Polysyllabic Words

    ERIC Educational Resources Information Center

    Yurtbasi, Metin

    2017-01-01

    Turkish students tend to make considerable stress placement errors when pronouncing English polysyllabic words because of the interference of the traditional word stress patterns of their mother tongue. They usually misplace stresses in their utterance, both either as a result of their native pronunciation habits or their lack of stress-placing…

  19. SU-F-P-42: “To Navigate, Or Not to Navigate: HDR BT in Recurrent Spine Lesions”

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Voros, L; Cohen, G; Zaider, M

    Purpose: We compare the accuracy of HDR catheter placement for paraspinal lesions using O-arm CBCT imaging combined with StealthStation navigation and traditional fluoroscopically guided catheter placement. Methods: CT and MRI scans were acquired pre-treatment to outline the lesions and design treatment plans (pre-plans) to meet dosimetric constrains. The pre-planned catheter trajectories were transferred into the StealthStation Navigation system prior to the surgery. The StealthStation is an infra red (IR) optical navigation system used for guidance of surgical instruments. An intraoperative CBCT scan (O-arm) was acquired with reference IR optical fiducials anchored onto the patient and registered with the preplan imagemore » study to guide surgical instruments in relation to the patients’ anatomy and to place the brachytherapy catheters along the pre-planned trajectories. The final treatment plan was generated based on a 2nd intraoperative CBCT scan reflecting achieved implant geometry. The 2nd CBCT was later registered with the initial CT scan to compare the preplanned dwell positions with actual dwell positions (catheter placements). Similar workflow was used in placement of 8 catheters (1 patient) without navigation, but under fluoroscopy guidance in an interventional radiology suite. Results: A total of 18 catheters (3 patients) were placed using navigation assisted surgery. Average displacement of 0.66 cm (STD=0.37cm) was observed between the pre-plan source positions and actual source positions in the 3 dimensional space. This translates into an average 0.38 cm positioning error in one direction including registration errors, digitization errors, and the surgeons ability to follow the planned trajectory. In comparison, average displacement of non-navigated catheters was 0.50 cm (STD=0.22cm). Conclusion: Spinal lesion HDR brachytherapy planning is a difficult task. Catheter placement has a direct impact on target coverage and dose to critical structures. While limited to a handful of patients, our experience shows navigation and fluoroscopy guided placement yield similar results.« less

  20. Graduate Students' Administration and Scoring Errors on the Woodcock-Johnson III Tests of Cognitive Abilities

    ERIC Educational Resources Information Center

    Ramos, Erica; Alfonso, Vincent C.; Schermerhorn, Susan M.

    2009-01-01

    The interpretation of cognitive test scores often leads to decisions concerning the diagnosis, educational placement, and types of interventions used for children. Therefore, it is important that practitioners administer and score cognitive tests without error. This study assesses the frequency and types of examiner errors that occur during the…

  1. Endothelin-1 Expression in Prostate Needle Biopsy Specimens Correlated With Aggressiveness of Prostatic Cancer

    PubMed Central

    Asgari, Mojgan; Eftekhar, Elham; Abolhasani, Maryam; Shahrokh, Hossein

    2017-01-01

    Background & Objective: As the prostate adenocarcinoma is one of the most common malignant tumors in males, looking for a marker to effectively predict aggressiveness and metastatic potential in an apparently localized cancer in initial needle biopsy specimens can help the clinicians to make more appropriate decision for treatment, planning, and choosing appropriate targeted therapy. The present study assessed the value of Endothelin-1 expression to predict prognosis of prostatic cancer Methods: In a cross sectional study, 83 patients who underwent radical prostatectomy in Hasheminejad Kidney Center in 2008 through 2012 were assigned to two groups including 43 with and 40 without extra-prostatic extension (EPE). Endothelin-1 staining was performed on Paraffin Embedded blocks of preoperative needle biopsies. Results: The expression of Endothelin-1 increased in 72% of patients in the group with EPE (P<0.001). The group with Endothelin-1 positivity showed higher serum level of prostate specific antigen (PSA) (p = 0.039). Endothelin-1 expression was positive in 67% of patients with perineurial invasion (P<0.001). Adjusting the baseline variables of PSA and PN in a multivariable logistic regression model, the Endothelin-1 positivity could effectively predict EPE in patients with prostatic cancer (OR: 5.46, p = 0.010). Conclusion: Correlation of Endothelin-1 expression in needle biopsy specimens in expected with extra-prostatic extension of tumor in radical prostatectomy specimens, perineurial invasion and serum PSA level at the time of diagnosis. PMID:29515640

  2. Peripheral Quantitative Computed Tomography: Measurement Sensitivity in Persons With and Without Spinal Cord Injury

    PubMed Central

    Shields, Richard K.; Dudley-Javoroski, Shauna; Boaldin, Kathryn M.; Corey, Trent A.; Fog, Daniel B.; Ruen, Jacquelyn M.

    2012-01-01

    Objectives To determine (1) the error attributable to external tibia-length measurements by using peripheral quantitative computed tomography (pQCT) and (2) the effect these errors have on scan location and tibia trabecular bone mineral density (BMD) after spinal cord injury (SCI). Design Blinded comparison and criterion standard in matched cohorts. Setting Primary care university hospital. Participants Eight able-bodied subjects underwent tibia length measurement. A separate cohort of 7 men with SCI and 7 able-bodied age-matched male controls underwent pQCT analysis. Interventions Not applicable. Main Outcome Measures The projected worst-case tibia-length–measurement error translated into a pQCT slice placement error of ±3mm. We collected pQCT slices at the distal 4% tibia site, 3mm proximal and 3mm distal to that site, and then quantified BMD error attributable to slice placement. Results Absolute BMD error was greater for able-bodied than for SCI subjects (5.87mg/cm3 vs 4.5mg/cm3). However, the percentage error in BMD was larger for SCI than able-bodied subjects (4.56% vs 2.23%). Conclusions During cross-sectional studies of various populations, BMD differences up to 5% may be attributable to variation in limb-length–measurement error. PMID:17023249

  3. Integrated modelling of H-mode pedestal and confinement in JET-ILW

    NASA Astrophysics Data System (ADS)

    Saarelma, S.; Challis, C. D.; Garzotti, L.; Frassinetti, L.; Maggi, C. F.; Romanelli, M.; Stokes, C.; Contributors, JET

    2018-01-01

    A pedestal prediction model Europed is built on the existing EPED1 model by coupling it with core transport simulation using a Bohm-gyroBohm transport model to self-consistently predict JET-ILW power scan for hybrid plasmas that display weaker power degradation than the IPB98(y, 2) scaling of the energy confinement time. The weak power degradation is reproduced in the coupled core-pedestal simulation. The coupled core-pedestal model is further tested for a 3.0 MA plasma with the highest stored energy achieved in JET-ILW so far, giving a prediction of the stored plasma energy within the error margins of the measured experimental value. A pedestal density prediction model based on the neutral penetration is tested on a JET-ILW database giving a prediction with an average error of 17% from the experimental data when a parameter taking into account the fuelling rate is added into the model. However the model fails to reproduce the power dependence of the pedestal density implying missing transport physics in the model. The future JET-ILW deuterium campaign with increased heating power is predicted to reach plasma energy of 11 MJ, which would correspond to 11-13 MW of fusion power in equivalent deuterium-tritium plasma but with isotope effects on pedestal stability and core transport ignored.

  4. Unicompartmental knee arthroplasty: is robotic technology more accurate than conventional technique?

    PubMed

    Citak, Mustafa; Suero, Eduardo M; Citak, Musa; Dunbar, Nicholas J; Branch, Sharon H; Conditt, Michael A; Banks, Scott A; Pearle, Andrew D

    2013-08-01

    Robotic-assisted unicompartmental knee arthroplasty (UKA) with rigid bone fixation "can significantly improve implant placement and leg alignment. The aim of this cadaveric study was to determine whether the use of robotic systems with dynamic bone tracking would provide more accurate UKA implant positioning compared to the conventional manual technique. Three-dimensional CT-based preoperative plans were created to determine the desired position and orientation for the tibial and femoral components. For each pair of cadaver knees, UKA was performed using traditional instrumentation on the left side and using a haptic robotic system on the right side. Postoperative CT scans were obtained and 3D-to-3D iterative closest point registration was performed. Implant position and orientation were compared to the preoperative plan. Surgical RMS errors for femoral component placement were within 1.9 mm and 3.7° in all directions of the planned implant position for the robotic group, while RMS errors for the manual group were within 5.4mm and 10.2°. Average RMS errors for tibial component placement were within 1.4mm and 5.0° in all directions for the robotic group; while, for the manual group, RMS errors were within 5.7 mm and 19.2°. UKA was more precise using a semiactive robotic system with dynamic bone tracking technology compared to the manual technique. Copyright © 2012 Elsevier B.V. All rights reserved.

  5. Accuracy and Repeatability of Trajectory Rod Measurement Using Laser Scanners.

    PubMed

    Liscio, Eugene; Guryn, Helen; Stoewner, Daniella

    2017-12-22

    Three-dimensional (3D) technologies contribute greatly to bullet trajectory analysis and shooting reconstruction. There are few papers which address the errors associated with utilizing laser scanning for bullet trajectory documentation. This study examined the accuracy and precision of laser scanning for documenting trajectory rods in drywall for angles between 25° and 90°. The inherent error range of 0.02°-2.10° was noted while the overall error for laser scanning ranged between 0.04° and 1.98°. The inter- and intraobserver errors for trajectory rod placement and virtual trajectory marking showed that the range of variation for rod placement was between 0.1°-1° in drywall and 0.05°-0.5° in plywood. Virtual trajectory marking accuracy tests showed that 75% of data values were below 0.91° and 0.61° on azimuth and vertical angles, respectively. In conclusion, many contributing factors affect bullet trajectory analysis, and the use of 3D technologies can aid in reduction of errors associated with documentation. © 2017 American Academy of Forensic Sciences.

  6. 77 FR 19112 - Final Flood Elevation Determinations

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-03-30

    ... Communities affected [caret] Elevation in meters (MSL) Modified Sumter County, Alabama, and Incorporated Areas... feet above ground. [caret] Mean Sea Level, rounded to the nearest 0.1 meter. ADDRESSES Town of Epes... Avenue. [[Page 19114

  7. Longitudinal changes in femur bone mineral density after spinal cord injury: effects of slice placement and peel method

    PubMed Central

    Dudley-Javoroski, S.

    2010-01-01

    Summary Surveillance of femur metaphysis bone mineral density (BMD) decline after spinal cord injury (SCI) may be subject to slice placement error of 2.5%. Adaptations to anti-osteoporosis measures should exceed this potential source of error. Image analysis parameters likewise affect BMD output and should be selected strategically in longitudinal studies. Introduction Understanding the longitudinal changes in bone mineral density (BMD) after spinal cord injury (SCI) is important when assessing new interventions. We determined the longitudinal effect of SCI on BMD of the femur metaphysis. To facilitate interpretation of longitudinal outcomes, we (1) determined the BMD difference associated with erroneous peripheral quantitative computed tomography (pQCT) slice placement, and (2) determined the effect of operator-selected pQCT peel algorithms on BMD. Methods pQCT images were obtained from the femur metaphysis (12% of length from distal end) of adult subjects with and without SCI. Slice placement errors were simulated at 3 mm intervals and were processed in two ways (threshold-based vs. concentric peel). Results BMD demonstrated a rapid decline over 2 years post-injury. BMD differences attributable to operator-selected peel methods were large (17.3% for subjects with SCI). Conclusions Femur metaphysis BMD declines after SCI in a manner similar to other anatomic sites. Concentric (percentage-based) peel methods may be most appropriate when special sensitivity is required to detect BMD adaptations. Threshold-based methods may be more appropriate when asymmetric adaptations are observed. PMID:19707702

  8. Complete data preparation flow for Massively Parallel E-Beam lithography on 28nm node full-field design

    NASA Astrophysics Data System (ADS)

    Fay, Aurélien; Browning, Clyde; Brandt, Pieter; Chartoire, Jacky; Bérard-Bergery, Sébastien; Hazart, Jérôme; Chagoya, Alexandre; Postnikov, Sergei; Saib, Mohamed; Lattard, Ludovic; Schavione, Patrick

    2016-03-01

    Massively parallel mask-less electron beam lithography (MP-EBL) offers a large intrinsic flexibility at a low cost of ownership in comparison to conventional optical lithography tools. This attractive direct-write technique needs a dedicated data preparation flow to correct both electronic and resist processes. Moreover, Data Prep has to be completed in a short enough time to preserve the flexibility advantage of MP-EBL. While the MP-EBL tools have currently entered an advanced stage of development, this paper will focus on the data preparation side of the work for specifically the MAPPER Lithography FLX-1200 tool [1]-[4], using the ASELTA Nanographics Inscale software. The complete flow as well as the methodology used to achieve a full-field layout data preparation, within an acceptable cycle time, will be presented. Layout used for Data Prep evaluation was one of a 28 nm technology node Metal1 chip with a field size of 26x33mm2, compatible with typical stepper/scanner field sizes and wafer stepping plans. Proximity Effect Correction (PEC) was applied to the entire field, which was then exported as a single file to MAPPER Lithography's machine format, containing fractured shapes and dose assignments. The Soft Edge beam to beam stitching method was employed in the specific overlap regions defined by the machine format as well. In addition to PEC, verification of the correction was included as part of the overall data preparation cycle time. This verification step was executed on the machine file format to ensure pattern fidelity and accuracy as late in the flow as possible. Verification over the full chip, involving billions of evaluation points, is performed both at nominal conditions and at Process Window corners in order to ensure proper exposure and process latitude. The complete MP-EBL data preparation flow was demonstrated for a 28 nm node Metal1 layout in 37 hours. The final verification step shows that the Edge Placement Error (EPE) is kept below 2.25 nm over an exposure dose variation of 8%.

  9. The reliability and validity of a portfolio designed as a programmatic assessment of performance in an integrated clinical placement.

    PubMed

    Roberts, Chris; Shadbolt, Narelle; Clark, Tyler; Simpson, Phillip

    2014-09-20

    Little is known about the technical adequacy of portfolios in reporting multiple complex academic and performance-based assessments. We explored, first, the influencing factors on the precision of scoring within a programmatic assessment of student learning outcomes within an integrated clinical placement. Second, the degree to which validity evidence supported interpretation of student scores. Within generalisability theory, we estimated the contribution that each wanted factor (i.e. student capability) and unwanted factors (e.g. the impact of assessors) made to the variation in portfolio task scores. Relative and absolute standard errors of measurement provided a confidence interval around a pre-determined pass/fail standard for all six tasks. Validity evidence was sought through demonstrating the internal consistency of the portfolio and exploring the relationship of student scores with clinical experience. The mean portfolio mark for 257 students, across 372 raters, based on six tasks, was 75.56 (SD, 6.68). For a single student on one assessment task, 11% of the variance in scores was due to true differences in student capability. The most significant interaction was context specificity (49%), the tendency for one student to engage with one task and not engage with another task. Rater subjectivity was 29%. An absolute standard error of measurement of 4.74%, gave a 95% CI of +/- 9.30%, and a 68% CI of +/- 4.74% around a pass/fail score of 57%. Construct validity was supported by demonstration of an assessment framework, the internal consistency of the portfolio tasks, and higher scores for students who did the clinical placement later in the academic year. A portfolio designed as a programmatic assessment of an integrated clinical placement has sufficient evidence of validity to support a specific interpretation of student scores around passing a clinical placement. It has modest precision in assessing students' achievement of a competency standard. There were identifiable areas for reducing measurement error and providing more certainty around decision-making. Reducing the measurement error would require engaging with the student body on the value of the tasks, more focussed academic and clinical supervisor training, and revisiting the rubric of the assessment in the light of feedback.

  10. Gender differences in patellofemoral load during the epee fencing lunge.

    PubMed

    Sinclair, J; Bottoms, L

    2015-01-01

    Clinical analyses have shown that injuries and pain linked specifically to fencing training/competition were prevalent in 92.8% of fencers. Patellofemoral pain is the most common chronic injury in athletic populations and females are considered to be more susceptible to this pathology. This study aimed to examine gender differences in patellofemoral contact forces during the fencing lunge. Patellofemoral contact forces were obtained from eight male and eight female club level epee fencers using an eight-camera 3D motion capture system and force platform data as they completed simulated lunges. Independent t-tests were performed on the data to determine whether gender differences in patellofemoral contact forces were present. The results show that females were associated with significantly greater patellofemoral contact force parameters in comparison with males. This suggests that female fencers may be at greater risk from patellofemoral pathology as a function of fencing training/competition.

  11. Comparison of technique errors of intraoral radiographs taken on film v photostimulable phosphor (PSP) plates.

    PubMed

    Zhang, Wenjian; Huynh, Carolyn P; Abramovitch, Kenneth; Leon, Inga-Lill K; Arvizu, Liliana

    2012-06-01

    The objective of this study was to compare the technical errors of intraoral radiographs exposed on film v photostimulable phosphor (PSP) plates. The intraoral radiographic images exposed on phantoms from preclinical practical exams of dental and dental hygiene students were used. Each exam consisted of 10 designated periapical and bitewing views. A total of 107 film sets and 122 PSP sets were evaluated for technique errors, including placement, elongation, foreshortening, overlapping, cone cut, receptor bending, density, mounting, dot in apical area, and others. Some errors were further subcategorized as minor, major, or remake depending on the severity. The percentages of radiographs with various errors were compared between film and PSP by the Fisher's Exact Test. Compared with film, there was significantly less PSP foreshortening, elongation, and bending errors, but significantly more placement and overlapping errors. Using a wrong sized receptor due to the similarity of the color of the package sleeves is a unique PSP error. Optimum image quality is attainable with PSP plates as well as film. When switching from film to a PSP digital environment, more emphasis is necessary for placing the PSP plates, especially those with excessive packet edge, and then correcting the corresponding angulation for the beam alignment. Better design for improving intraoral visibility and easy identification of different sized PSP will improve the clinician's technical performance with this receptor.

  12. Rewriting evolution--"been there, done that".

    PubMed

    Penny, David

    2013-01-01

    A recent paper by a science journalist in Nature shows major errors in understanding phylogenies, in this case of placental mammals. The underlying unrooted tree is probably correct, but the placement of the root just reflects a well-known error from the acceleration in the rate of evolution among some myomorph rodents.

  13. Medical telementoring using an augmented reality transparent display.

    PubMed

    Andersen, Daniel; Popescu, Voicu; Cabrera, Maria Eugenia; Shanghavi, Aditya; Gomez, Gerardo; Marley, Sherri; Mullis, Brian; Wachs, Juan P

    2016-06-01

    The goal of this study was to design and implement a novel surgical telementoring system called the System for Telementoring with Augmented Reality (STAR) that uses a virtual transparent display to convey precise locations in the operating field to a trainee surgeon. This system was compared with a conventional system based on a telestrator for surgical instruction. A telementoring system was developed and evaluated in a study which used a 1 × 2 between-subjects design with telementoring system, that is, STAR or conventional, as the independent variable. The participants in the study were 20 premedical or medical students who had no prior experience with telementoring. Each participant completed a task of port placement and a task of abdominal incision under telementoring using either the STAR or the conventional system. The metrics used to test performance when using the system were placement error, number of focus shifts, and time to task completion. When compared with the conventional system, participants using STAR completed the 2 tasks with less placement error (45% and 68%) and with fewer focus shifts (86% and 44%), but more slowly (19% for each task). Using STAR resulted in decreased annotation placement error, fewer focus shifts, but greater times to task completion. STAR placed virtual annotations directly onto the trainee surgeon's field of view of the operating field by conveying location with great accuracy; this technology helped to avoid shifts in focus, decreased depth perception, and enabled fine-tuning execution of the task to match telementored instruction, but led to greater times to task completion. Copyright © 2016 Elsevier Inc. All rights reserved.

  14. Articulatory Placement for /t/, /d/, /k/ and /g/ Targets in School Age Children with Speech Disorders Associated with Cleft Palate

    ERIC Educational Resources Information Center

    Gibbon, Fiona; Ellis, Lucy; Crampin, Lisa

    2004-01-01

    This study used electropalatography (EPG) to identify place of articulation for lingual plosive targets /t/, /d/, /k/ and /g/ in the speech of 15 school age children with repaired cleft palate. Perceptual judgements indicated that all children had correct velar placement for /k/, /g/ targets, but /t/, /d/ targets were produced as errors involving…

  15. Accuracy analysis of pedicle screw placement in posterior scoliosis surgery: comparison between conventional fluoroscopic and computer-assisted technique.

    PubMed

    Kotani, Yoshihisa; Abumi, Kuniyoshi; Ito, Manabu; Takahata, Masahiko; Sudo, Hideki; Ohshima, Shigeki; Minami, Akio

    2007-06-15

    The accuracy of pedicle screw placement was evaluated in posterior scoliosis surgeries with or without the use of computer-assisted surgical techniques. In this retrospective cohort study, the pedicle screw placement accuracy in posterior scoliosis surgery was compared between conventional fluoroscopic and computer-assisted surgical techniques. There has been no study systemically analyzing the perforation pattern and comparative accuracy of pedicle screw placement in posterior scoliosis surgery. The 45 patients who received posterior correction surgeries were divided into 2 groups: Group C, manual control (25 patients); and Group N, navigation surgery (20 patients). The average Cobb angles were 73.7 degrees and 73.1 degrees before surgery in Group C and Group N, respectively. Using CT images, vertebral rotation, pedicle axes as measured to anteroposterior sacral axis and vertebral axis, and insertion angle error were measured. In perforation cases, the angular tendency, insertion point, and length abnormality were evaluated. The perforation was observed in 11% of Group C and 1.8% in Group N. In Group C, medial perforations of left screws were demonstrated in 8 of 9 perforated screws and 55% were distributed either in L1 or T12. The perforation consistently occurred in pedicles in which those axes approached anteroposterior sacral axis within 5 degrees . The average insertion errors were 8.4 degrees and 5.0 degrees in Group C and Group N, respectively, which were significantly different (P < 0.02). The medial perforation in Group C occurred around L1, especially when pedicle axis approached anteroposterior sacral axis. This consistent tendency was considered as the limitation of fluoroscopic screw insertion in which horizontal vertebral image was not visible. The use of surgical navigation system successfully reduced the perforation rate and insertion angle errors, demonstrating the clear advantage in safe and accurate pedicle screw placement of scoliosis surgery.

  16. Rewriting Evolution—“Been There, Done That”

    PubMed Central

    Penny, David

    2013-01-01

    A recent paper by a science journalist in Nature shows major errors in understanding phylogenies, in this case of placental mammals. The underlying unrooted tree is probably correct, but the placement of the root just reflects a well-known error from the acceleration in the rate of evolution among some myomorph rodents. PMID:23558594

  17. Usefulness of intraoperative radiographs in reducing errors of cup placement and leg length during total hip arthroplasty.

    PubMed

    Wind, Michael A; Morrison, J Craig; Christie, Michael J

    2013-11-01

    Traditional methods of component placement during total hip arthroplasty (THA) can lead to errors in cup abduction angle and leg length. Intraoperative radiographs were used to assess and correct errors during surgery in a consecutive series of 278 THAs performed by a single surgeon. After exclusions, 262 cases were available for cup abduction angle assessment and 224 for leg length discrepancy (LLD) assessment. Components were initially placed in a position determined as appropriate by the surgeon. Intraoperative radiographs were taken and appropriate corrections made. Postoperative radiographs were assessed at 6 weeks. Mean abduction angle on intraoperative radiographs was 39.6°±5.9° versus 38.6°±4.1° on postoperative radiographs. Thirty-eight cups were outside the target abduction range on intraoperative radiographs versus 4 on postoperative radiographs. Mean LLD was 3.7 mm ± 3.6 mm on intraoperative radiographs and 2.5 mm ± 2.7 mm on postoperative radiographs. Use of intraoperative radiographs is a valid, useful technique for minimizing errors in THA.

  18. Treatment planning for prostate focal laser ablation in the face of needle placement uncertainty

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cepek, Jeremy, E-mail: jcepek@robarts.ca; Fenster, Aaron; Lindner, Uri

    2014-01-15

    Purpose: To study the effect of needle placement uncertainty on the expected probability of achieving complete focal target destruction in focal laser ablation (FLA) of prostate cancer. Methods: Using a simplified model of prostate cancer focal target, and focal laser ablation region shapes, Monte Carlo simulations of needle placement error were performed to estimate the probability of completely ablating a region of target tissue. Results: Graphs of the probability of complete focal target ablation are presented over clinically relevant ranges of focal target sizes and shapes, ablation region sizes, and levels of needle placement uncertainty. In addition, a table ismore » provided for estimating the maximum target size that is treatable. The results predict that targets whose length is at least 5 mm smaller than the diameter of each ablation region can be confidently ablated using, at most, four laser fibers if the standard deviation in each component of needle placement error is less than 3 mm. However, targets larger than this (i.e., near to or exceeding the diameter of each ablation region) require more careful planning. This process is facilitated by using the table provided. Conclusions: The probability of completely ablating a focal target using FLA is sensitive to the level of needle placement uncertainty, especially as the target length approaches and becomes greater than the diameter of ablated tissue that each individual laser fiber can achieve. The results of this work can be used to help determine individual patient eligibility for prostate FLA, to guide the planning of prostate FLA, and to quantify the clinical benefit of using advanced systems for accurate needle delivery for this treatment modality.« less

  19. 78 FR 27960 - Combined Notice of Filings #1

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-05-13

    ... that the Commission received the following electric rate filings: Docket Numbers: ER13-37-003...-1415-000. Applicants: El Paso Electric Company. Description: Concurrence of EPE to APS Service...: ER13-1417-000. Applicants: Niagara Mohawk Power Corporation. Description: Notice of Cancellation of...

  20. Triton Mosaic

    NASA Image and Video Library

    1999-08-25

    Mosaic of Triton constructed from 16 individual images. After globally minimizing the camera pointing errors, the frames we reprocessed by map projections, photometric function removal and placement in the mosaic.

  1. Toxicokinetics of 1,2-diethylbenzene in male Sprague-Dawley rats-part 1: excretion and metabolism of [(14)C]1,2-diethylbenzene.

    PubMed

    Payan, J P; Beydon, D; Cossec, B; Ensminger, A; Fabry, J P; Ferrari, E

    1999-12-01

    The excretion and metabolism of neurotoxic 1,2-diethylbenzene (1, 2-DEB) was studied in male Sprague-Dawley rats after i.v. (1 mg/kg) or oral (1 or 100 mg/kg) administration of 1,2-diethyl[U-(14)C]benzene ([(14)C]1,2-DEB). Whatever the treatment, radioactivity was mainly excreted in urine (65-76% of the dose) and to a lower extent in feces (15-23% of the dose), or via exhaled air (3-5% of the dose). However, experiments with rats fitted with a biliary cannula demonstrated that about 52 to 64% of the administered doses (1 or 100 mg/kg) were initially excreted in bile. Biliary metabolites were extensively reabsorbed from the gut and ultimately excreted in urine after several enterohepatic circulations. Insignificant amounts of unchanged 1,2-DEB were recovered in the different excreta (urine, bile, and feces). As reported previously, presence of 1-(2'-ethylphenyl)ethanol (EPE) was confirmed in urine and demonstrated in bile and feces. The two main [(14)C]1,2-DEB metabolites accounted for 57 to 79% of urinary and biliary radioactivity, respectively. Beta-Glucuronidase hydrolysis and electron impact mass spectra results strongly supported their glucuronide structure. Additionally, these two main metabolites were thought to be the glucuronide conjugates of the two potential enantiomers of EPE. The results indicate that the main initial conversion step of the primary metabolic pathway of 1,2-DEB appears to be the hydroxylation of the alpha-carbon atom of the side chain. The presence of two glucuronide conjugates of EPE in the urine in a ratio different from one suggests that the metabolic conversion of 1, 2-DEB is under stereochemical control.

  2. Impact of the integration of proton magnetic resonance imaging spectroscopy to PI-RADS 2 for prediction of high grade and high stage prostate cancer.

    PubMed

    Leapman, Michael S; Wang, Zhen J; Behr, Spencer C; Kurhanewicz, John; Zagoria, Ronald J; Carroll, Peter R; Westphalen, Antonio C

    2017-01-01

    To compare the predictions of dominant Gleason pattern ≥ 4 or non-organ confined disease with Prostate Imaging Reporting and Data System (PI-RADS v2) with or without proton magnetic resonance spectroscopic imaging ( 1 H-MRSI). Thirty-nine men underwent 3-tesla endorectal multiparametric MRI including 1 H-MRSI and prostatectomy. Two radiologists assigned PI-RADS v2 and 1 H-MRSI scores to index lesions. Statistical analyses used logistic regressions, receiver operating characteristic (ROC) curves, and 2x2 tables for diagnostic accuracies. The sensitivity and specificity of 1 H-MRSI and PI-RADS v2 for high-grade prostate cancer (PCa) were 85.7% (57.1%) and 92.9% (100%), and 56% (68.0%) and 24.0% (24.0%). The sensitivity and specificity of 1 H-MRSI and PI-RADS v2 for extra-prostatic extension (EPE) were 64.0% (40%) and 20.0% (48%), and 50.0% (57.1%) and 71.4% (64.3%). The area under the ROC curves (AUC) for prediction of high-grade prostate cancer were 0.65 and 0.61 for PI-RADS v2 and 0.72 and 0.70 when combined with 1 H-MRSI (readers 1 and 2, p = 0.04 and 0.21). For prediction of EPE the AUC were 0.54 and 0.60 for PI-RADS v2 and 0.55 and 0.61 when combined with 1 H-MRSI ( p > 0.05). 1 H-MRSI might improve the discrimination of high-grade prostate cancer when combined to PI-RADS v2, particularly for PI-RADS v2 score 4 lesions, but it does not affect the prediction of EPE.

  3. The rabbit as an infection model for equine proliferative enteropathy

    PubMed Central

    Sampieri, Francesca; Allen, Andrew L.; Pusterla, Nicola; Vannucci, Fabio A.; Antonopoulos, Aphroditi J.; Ball, Katherine R.; Thompson, Julie; Dowling, Patricia M.; Hamilton, Don L.; Gebhart, Connie J.

    2013-01-01

    The objective of this study was to demonstrate the susceptibility of rabbits to Lawsonia intracellularis obtained from a case of clinical equine proliferative enteropathy (EPE). This is a preliminary step toward developing a rabbit infection model for studying pathogenesis and therapy of EPE in horses. Nine does were equally assigned to 3 groups. Animals in 2 groups (Group 1 and Group 2) were orally inoculated with different doses of cell-cultured L. intracellularis. Controls (Group 3) were sham-inoculated. Feces and blood were collected before the rabbits were infected and at 7, 14, and 21 days post-infection (DPI). Serum immunoglobulin G (IgG) titers were measured using an immunoperoxidase monolayer assay (IPMA) and fecal samples were analyzed with quantitative polymerase chain reaction (qPCR). A doe from each group was euthanized at 7, 14, and 21 DPI for collection and evaluation of intestinal samples. Tissues were stained by routine hematoxylin and eosin (H&E) method and immunohistochemistry (IHC) with L. intracellularis-specific mouse monoclonal antibody. At 14 DPI, serologic responses were detected in both infected groups, which maintained high titers through to 21 DPI. Lawsonia intracellularis DNA was detected in the feces of Group 2 on 7 DPI and in both infected groups on 14 DPI. Gross lesions were apparent in Group 1 and Group 2 on 14 DPI. Immunohistochemistry confirmed L. intracellularis antigen within cells of rabbits in Group 1 and Group 2 on 7, 14, and 21 DPI. No lesions, serologic response, shedding, or IHC labeling were found in Group 3 rabbits. This study describes an EPE rabbit model that simulates natural infection, as typical lesions, immune response, and fecal shedding were present. PMID:24082402

  4. Adverse pathology and undetectable ultrasensitive prostate-specific antigen after radical prostatectomy: is adjuvant radiation warranted?

    PubMed

    Simon, Ross M; Howard, Lauren E; Freedland, Stephen J; Aronson, William J; Terris, Martha K; Kane, Christopher J; Amling, Christopher L; Cooperberg, Matthew R; Vidal, Adriana C

    2016-06-01

    To determine if men with adverse pathology but undetectable ultrasensitive (<0.01 ng/mL) PSA are at high-risk for biochemical recurrence (BCR), or if there is a subset of patients at low-risk for whom the benefit of adjuvant radiation therapy might be limited. We evaluated 411 patients treated with RP from 2001 to 2013 without adjuvant radiation who had an undetectable (<0.01 ng/mL) PSA level after RP but with adverse pathology [positive surgical margins (PSMs), extraprostatic extension (EPE), and/or seminal vesicle invasion (SVI)]. Multivariable Cox regression analyses tested the relationship between pathological characteristics and BCR to identify groups of men at highest risk of early BCR. On multivariable analysis, only pathological Gleason 7 (4 + 3), Gleason ≥8, and SVI independently predicted BCR (P = 0.019, P < 0.001, and P = 0.001, respectively), although on two-way analysis men with Gleason 7 (4 + 3) did not have significantly higher rates of BCR compared with patients with Gleason ≤6 (log-rank, P = 0.074). Men with either Gleason ≥8 (with PSMs or EPE) or SVI (15% of the cohort) defined a high-risk group vs men without these characteristics (3-year BCR risk of 50.4% vs 11.9%, log-rank, P < 0.001). Among men with adverse pathology but an undetectable (<0.01 ng/mL) PSA level after RP, the benefits of adjuvant radiation are probably limited except for men with Gleason 8-10 (with PSMs or EPE) or SVI who are at high-risk of early BCR. © 2015 The Authors BJU International © 2015 BJU International Published by John Wiley & Sons Ltd.

  5. Preclinical evaluation of an MRI-compatible pneumatic robot for angulated needle placement in transperineal prostate interventions.

    PubMed

    Tokuda, Junichi; Song, Sang-Eun; Fischer, Gregory S; Iordachita, Iulian I; Seifabadi, Reza; Cho, Nathan B; Tuncali, Kemal; Fichtinger, Gabor; Tempany, Clare M; Hata, Nobuhiko

    2012-11-01

    To evaluate the targeting accuracy of a small profile MRI-compatible pneumatic robot for needle placement that can angulate a needle insertion path into a large accessible target volume. We extended our MRI-compatible pneumatic robot for needle placement to utilize its four degrees-of-freedom (4-DOF) mechanism with two parallel triangular structures and support transperineal prostate biopsies in a closed-bore magnetic resonance imaging (MRI) scanner. The robot is designed to guide a needle toward a lesion so that a radiologist can manually insert it in the bore. The robot is integrated with navigation software that allows an operator to plan angulated needle insertion by selecting a target and an entry point. The targeting error was evaluated while the angle between the needle insertion path and the static magnetic field was between -5.7° and 5.7° horizontally and between -5.7° and 4.3° vertically in the MRI scanner after sterilizing and draping the device. The robot positioned the needle for angulated insertion as specified on the navigation software with overall targeting error of 0.8 ± 0.5mm along the horizontal axis and 0.8 ± 0.8mm along the vertical axis. The two-dimensional root-mean-square targeting error on the axial slices as containing the targets was 1.4mm. Our preclinical evaluation demonstrated that the MRI-compatible pneumatic robot for needle placement with the capability to angulate the needle insertion path provides targeting accuracy feasible for clinical MRI-guided prostate interventions. The clinical feasibility has to be established in a clinical study.

  6. Validity of the Omron HJ-112 pedometer during treadmill walking.

    PubMed

    Hasson, Rebecca E; Haller, Jeannie; Pober, David M; Staudenmayer, John; Freedson, Patty S

    2009-04-01

    The purpose of this investigation was to examine the validity of step counts measured with the Omron HJ-112 pedometer and to assess the effect of pedometer placement. Ninety-two subjects (44 males and 48 females; 71 with body mass index [BMI] <30 kg.m and 21 with BMI >or=30 kg.m) completed three, 12-min bouts of treadmill walking at speeds of 1.12, 1.34, and 1.56 mxs. A subset (21 males and 23 females; 38 BMI <30 kg.m and 6 BMI >or=30 kg.m) completed a variable walking condition. For all conditions, participants wore an Omron HJ-112 pedometer on the hip, in the pants pocket, in the chest shirt pocket, and around the neck. Hip pedometer placement was alternated between right and left sides with the Yamax Digiwalker SW-701. During each walk, an investigator recorded actual steps with a manual hand counter. There was no substantial bias with the Omron in any speed condition (-0.1% to 0.5%). Bias was larger with the Yamax (-3.6% to 2.0%). The largest random error for the Omron was 3.7% in the variable-speed condition for the BMI <30 kg.m group, whereas random errors for the Yamax were larger and up to 20%. None of the Omron placement positions produced statistically significant bias. Hip mounting produced the smallest random error (1.2%), followed by shirt pocket (1.7%), neck (2.2%), and pants pocket (5.8%). The Omron HJ-112 pedometer validly assesses steps in different BMI groups during constant- and variable-speed walking; other than that in the pants pocket, placement of the pedometer has little effect on validity.

  7. Portugal's Secondary School Modernisation Programme

    ERIC Educational Resources Information Center

    Heitor, Teresa V.; Freire da Silva, Jose M. R.

    2009-01-01

    The aim of the Secondary School Modernisation Programme, being implemented in Portugal by "Parque Escolar, EPE", is based on the pursuit of quality and makes Portuguese education a potential international benchmark. This paper discusses the strategies adopted to reorganise school spaces. It describes the conceptual model and highlights…

  8. An Exercise Protocol Designed to control Energy Expenditure and to have a Positive Impact on Maximal Oxygen Consumption for Long-Term Space Missions

    NASA Astrophysics Data System (ADS)

    Matsuo, Tomoaki; Ohkawara, Kazunori; Seino, Satoshi; Shimojo, Nobutake; Yamada, Shin; Ohshima, Hiroshi; Tanaka, Kiyoji; Mukai, Chiaki

    2013-02-01

    Maximal oxygen consumption decreases during spaceflight, and astronauts also experience controversial weight loss. Future space missions require a more efficient exercise program to maintain work efficiency and to control increased energy expenditure (EE). We have been developing two types of original exercise training protocols which are better suited to astronauts’ daily routine exercise during long-term spaceflight: sprint interval training (SIT) and high-intensity interval aerobic training (HIAT). In this study, we compared the total EE, including excess post-exercise energy expenditure (EPEE), induced by our interval cycling protocols with the total EE of a traditional, continuous aerobic training (CAT). In the results, while the EPEEs after the SIT and HIAT were greater than after the CAT, the total EE for an entire exercise/rest session with the CAT was the greatest of our three exercise protocols. The SIT and HIAT would be potential protocols to control energy expenditure for long space missions.

  9. Energetic Particles Events inside Magnetic Clouds

    NASA Astrophysics Data System (ADS)

    Medina, Jose; Hidalgo, Miguel Angel; Blanco, Juan Jose; Rodriguez-Pacheco, Javier

    The effect of the magnetic topology of the Magnetic Clouds (MCs) over the energetic particle event (EPe) fluxes (0.5-100 MeV) have been simulated. In the data corresponding to the ion and electron fluxes, a depression after a strong maximum is observed when a EPe passes through a MC. Using our cross-section circular and elliptical MC models (Journal of Geophysical Research 107(1), doi:10.1029/2001JA900100 (2002) and Solar Physics 207(1), 187-198 (2002)) we have tried to explain that effect, understanding the importance of the topology of the MC. In sight of the results of the preliminary analysis we conclude that the magnitude of the magnetic field seems not to play a significant role but the helicoidal topology associated with topology of the MCs. This work has been supported by the Spanish Comisín Internacional de o Ciencia y Tecnoloǵ (CICYT), grant ESP2005-07290-C02-01 and ESP2006-08459. This work ıa is performed inside COST Action 724.

  10. Design of the annular suspension and pointing system /ASPS/ through decoupling and pole placement. [for Space Shuttle

    NASA Technical Reports Server (NTRS)

    Kuo, B. C.; Lin, W. C. W.

    1980-01-01

    A decoupling and pole-placement technique has been developed for the Annular Suspension and Pointing System (ASPS) of the Space Shuttle which uses bandwidths as performance criteria. The dynamics of the continuous-data ASPS allows the three degrees of freedom to be totally decoupled by state feedback through constant gains, so that the bandwidth of each degree of freedom can be independently specified without interaction. Although it is found that the digital ASPS cannot be completely decoupled, the bandwidth requirements are satisfied by pole placement and a trial-and-error method based on approximate decoupling.

  11. Effects of the Booroola (FecB) genotypes on growth performance, ewe's productivity efficiency and litter size in Garole x Malpura sheep.

    PubMed

    Kumar, S; Mishra, A K; Kolte, A P; Arora, A L; Singh, D; Singh, V K

    2008-05-01

    The present study was conducted to evaluate the effects of FecB genotypes on body weight, average daily gain (ADG), ewe's productivity efficiency (EPE) and litter size in FecB introgressed GarolexMalpura (GM) crossbred sheep. A total of 235 GM lambs were selected randomly and screened for FecB mutation using forced RFLP-PCR. The majority (69.8%) of GM individuals were carriers (BB and B+) for the FecB mutation and frequency of the FecB allele was about 0.40. The FecB genotypes were significantly (P<0.01) associated with the lamb's body weights from birth to 12 months of age. The generation wise (F(1), F(2) and F(3)), lamb's body weight did not differ significantly at birth, 6 and 12 months of the age, while it differed significantly (P<0.05) at 3 and 9 months of age. The ADG1 (0-3 months) was significantly associated (P<0.05), but not the ADG2 (3-6 months) and ADG3 (6-12 months) between genotypes. Type of birth and sex significantly (P<0.01) affected the body weight from birth to 12 months of age; and body weight of single born lambs was significantly higher (P<0.01) than that of twins and triplets from birth to 12 months of age. Type of birth significantly (P<0.01) affected the ADG1, but had no significant effect on ADG2 and ADG3. Year of birth did not affect the birth and weaning weights, but it significantly affected (P<0.01) the body weight and ADG's after weaning ages. The EPE was affected significantly (P<0.01) by the FecB genotypes at birth, 3 and 12 months of age. The EPE of B+ and BB ewes were 7.86 kg (36.9%) and 2.32 kg (10.9%) higher as compared to ++ ewes at 12 months of age, respectively. The mean litter size of BB ewes (2.17+/-0.24) was significantly higher (P<0.01) than that of B+ ewes (1.73+/-0.04) and ++ ewes (1.03+/-0.23). The present study indicated that the body weight and ADG of carrier lambs (BB and B+) was comparatively lower than that of non-carriers (++), while EPE of B+ ewes was comparatively higher than that of BB and ++ ewes. Further, it is interesting to note that heterozygous and homozygous state of individuals increased 0.70 and 1.14 extra lambs as compared to non-carriers (++), respectively.

  12. Analysis of electrodes' placement and deformation in deep brain stimulation from medical images

    NASA Astrophysics Data System (ADS)

    Mehri, Maroua; Lalys, Florent; Maumet, Camille; Haegelen, Claire; Jannin, Pierre

    2012-02-01

    Deep brain stimulation (DBS) is used to reduce the motor symptoms such as rigidity or bradykinesia, in patients with Parkinson's disease (PD). The Subthalamic Nucleus (STN) has emerged as prime target of DBS in idiopathic PD. However, DBS surgery is a difficult procedure requiring the exact positioning of electrodes in the pre-operative selected targets. This positioning is usually planned using patients' pre-operative images, along with digital atlases, assuming that electrode's trajectory is linear. However, it has been demonstrated that anatomical brain deformations induce electrode's deformations resulting in errors in the intra-operative targeting stage. In order to meet the need of a higher degree of placement accuracy and to help constructing a computer-aided-placement tool, we studied the electrodes' deformation in regards to patients' clinical data (i.e., sex, mean PD duration and brain atrophy index). Firstly, we presented an automatic algorithm for the segmentation of electrode's axis from post-operative CT images, which aims to localize the electrodes' stimulated contacts. To assess our method, we applied our algorithm on 25 patients who had undergone bilateral STNDBS. We found a placement error of 0.91+/-0.38 mm. Then, from the segmented axis, we quantitatively analyzed the electrodes' curvature and correlated it with patients' clinical data. We found a positive significant correlation between mean curvature index of the electrode and brain atrophy index for male patients and between mean curvature index of the electrode and mean PD duration for female patients. These results help understanding DBS electrode' deformations and would help ensuring better anticipation of electrodes' placement.

  13. Effect of surgical guide design and surgeon's experience on the accuracy of implant placement.

    PubMed

    Hinckfuss, Simon; Conrad, Heather J; Lin, Lianshan; Lunos, Scott; Seong, Wook-Jin

    2012-08-01

    Implant position is a key determinant of esthetic and functional success. Achieving the goal of ideal implant position may be affected by case selection, prosthodontically driven treatment planning, site preparation, surgeon's experience and use of a surgical guide. The combined effect of surgical guide design, surgeon's experience, and size of the edentulous area on the accuracy of implant placement was evaluated in a simulated clinical setting. Twenty-one volunteers were recruited to participate in the study. They were divided evenly into 3 groups (novice, intermediate, and experienced). Each surgeon placed implants in single and double sites using 4 different surgical guide designs (no guide, tube, channel, and guided) and written instructions describing the ideal implant positions. A definitive typodont was constructed that had 3 implants in prosthetically determined ideal positions of single and double sites. The position and angulation of implants placed by the surgeons in the duplicate typodonts was measured using a computerized coordinate measuring machine and compared to the definitive typodont. The mean absolute positional error for all guides was 0.273, 0.340, 0.197 mm in mesial-distal, buccal-lingual, vertical positions, respectively, with an overall range of 0.00 to 1.81 mm. The mean absolute angle error for all guides was 1.61° and 2.39° in the mesial-distal and buccal-lingual angulations, respectively, with an overall range of 0.01° to 9.7°. Surgical guide design had a statistically significant effect on the accuracy of implant placement regardless of the surgeon's experience level. Experienced surgeons had significantly less error in buccal-lingual angulation. The size of the edentulous sites was found to affect both implant angle and position significantly. The magnitude of error in position and angulation caused by surgical guide design, surgeon's experience, and site size reported in this study are possibly not large enough to be clinically significant; however, it is likely that errors would be magnified in clinical practice. Future research is recommended to evaluate the effect of surgical guide design in vivo on implant angulation and position error.

  14. Technical Note: Error metrics for estimating the accuracy of needle/instrument placement during transperineal magnetic resonance/ultrasound-guided prostate interventions.

    PubMed

    Bonmati, Ester; Hu, Yipeng; Villarini, Barbara; Rodell, Rachael; Martin, Paul; Han, Lianghao; Donaldson, Ian; Ahmed, Hashim U; Moore, Caroline M; Emberton, Mark; Barratt, Dean C

    2018-04-01

    Image-guided systems that fuse magnetic resonance imaging (MRI) with three-dimensional (3D) ultrasound (US) images for performing targeted prostate needle biopsy and minimally invasive treatments for prostate cancer are of increasing clinical interest. To date, a wide range of different accuracy estimation procedures and error metrics have been reported, which makes comparing the performance of different systems difficult. A set of nine measures are presented to assess the accuracy of MRI-US image registration, needle positioning, needle guidance, and overall system error, with the aim of providing a methodology for estimating the accuracy of instrument placement using a MR/US-guided transperineal approach. Using the SmartTarget fusion system, an MRI-US image alignment error was determined to be 2.0 ± 1.0 mm (mean ± SD), and an overall system instrument targeting error of 3.0 ± 1.2 mm. Three needle deployments for each target phantom lesion was found to result in a 100% lesion hit rate and a median predicted cancer core length of 5.2 mm. The application of a comprehensive, unbiased validation assessment for MR/US guided systems can provide useful information on system performance for quality assurance and system comparison. Furthermore, such an analysis can be helpful in identifying relationships between these errors, providing insight into the technical behavior of these systems. © 2018 American Association of Physicists in Medicine.

  15. U.S. EPA, Pesticide Product Label, MEADOWS FLEA & TICK SPRAY, 01/12/1983

    EPA Pesticide Factsheets

    2011-04-14

    ... w.eping .. utlun,huld\\!I!I the di.p.II.lIr approxilllllt .. ly on .. foot ftom f"lt..g". <;I,r:>y botb upp.r .ud lo .... r leAf .. urf.c •• unttl visibly Wilt. Rp •• t •• n •• od ,--- ...

  16. Compatibility of separatrix density scaling for divertor detachment with H-mode pedestal operation in DIII-D

    NASA Astrophysics Data System (ADS)

    Leonard, A. W.; McLean, A. G.; Makowski, M. A.; Stangeby, P. C.

    2017-08-01

    The midplane separatrix density is characterized in response to variations in upstream parallel heat flux density and central density through deuterium gas injection. The midplane density is determined from a high spatial resolution Thomson scattering diagnostic at the midplane with power balance analysis to determine the separatrix location. The heat flux density is varied by scans of three parameters, auxiliary heating, toroidal field with fixed plasma current, and plasma current with fixed safety factor, q 95. The separatrix density just before divertor detachment onset is found to scale consistent with the two-point model when radiative dissipation is taken into account. The ratio of separatrix to pedestal density, n e,sep/n e,ped varies from  ⩽30% to  ⩾60% over the dataset, helping to resolve the conflicting scaling of core plasma density limit and divertor detachment onset. The scaling of the separatrix density at detachment onset is combined with H-mode power threshold scaling to obtain a scaling ratio of minimum n e,sep/n e,ped expected in future devices.

  17. Parameter dependence of ELM loss reduction by magnetic perturbations at low pedestal density and collisionality in ASDEX upgrade

    NASA Astrophysics Data System (ADS)

    Leuthold, N.; Suttrop, W.; Fischer, R.; Kappatou, A.; Kirk, A.; McDermott, R.; Mlynek, A.; Valovič, M.; Willensdorfer, M.; the ASDEX Upgrade Team; the EUROfusion MST1 Team

    2017-05-01

    ELM mitigation by magnetic perturbations is studied at low pedestal collisionalities down to ITER-like values ({ν }{e,{PED}}* =0.1) in ASDEX Upgrade. A comprehensive database of ELM energy losses for varying plasma density, heating power, edge safety factor and magnetic perturbation structure has been assembled to investigate parameter dependencies of ELM mitigation. It is found that magnetic perturbations with a toroidal mode number n = 2 can reduce the ELM energy loss normalized to the energy stored in the plasma pedestal from about 30% to less than 5%, i.e. by a factor of six, below an electron pedestal collisionality of {ν }{e,{PED}}* =0.4. At this level of ELM mitigation a significant reduction of the pedestal pressure and, therefore, global plasma confinement occurs. This pedestal pressure reduction is mostly due to a reduction of plasma density, the so-called ‘pump-out’ effect. Refueling by neutral beams and in particular by pellet injection is possible and can re-establish confinement, however, the ELM energy loss increases as well with increasing density.

  18. Will-Nordtvedt PPN formalism applied to renormalization group extensions of general relativity

    NASA Astrophysics Data System (ADS)

    Toniato, Júnior D.; Rodrigues, Davi C.; de Almeida, Álefe O. F.; Bertini, Nicolas

    2017-09-01

    We apply the full Will-Nordtvedt version of the parametrized post-Newtonian (PPN) formalism to a class of general relativity extensions that are based on nontrivial renormalization group (RG) effects at large scales. We focus on a class of models in which the gravitational coupling constant G is correlated with the Newtonian potential. A previous PPN analysis considered a specific realization of the RG effects, and only within the Eddington-Robertson-Schiff version of the PPN formalism, which is a less complete and robust PPN formulation. Here we find stronger, more precise bounds, and with less assumptions. We also consider the external potential effect (EPE), which is an effect that is intrinsic to this framework and depends on the system environment (it has some qualitative similarities to the screening mechanisms of modified gravity theories). We find a single particular RG realization that is not affected by the EPE. Some physical systems have been pointed out as candidates for measuring the possible RG effects in gravity at large scales; for any of them the Solar System bounds need to be considered.

  19. Predictive modeling of pedestal structure in KSTAR using EPED model

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Han, Hyunsun; Kim, J. Y.; Kwon, Ohjin

    2013-10-15

    A predictive calculation is given for the structure of edge pedestal in the H-mode plasma of the KSTAR (Korea Superconducting Tokamak Advanced Research) device using the EPED model. Particularly, the dependence of pedestal width and height on various plasma parameters is studied in detail. The two codes, ELITE and HELENA, are utilized for the stability analysis of the peeling-ballooning and kinetic ballooning modes, respectively. Summarizing the main results, the pedestal slope and height have a strong dependence on plasma current, rapidly increasing with it, while the pedestal width is almost independent of it. The plasma density or collisionality gives initiallymore » a mild stabilization, increasing the pedestal slope and height, but above some threshold value its effect turns to a destabilization, reducing the pedestal width and height. Among several plasma shape parameters, the triangularity gives the most dominant effect, rapidly increasing the pedestal width and height, while the effect of elongation and squareness appears to be relatively weak. Implication of these edge results, particularly in relation to the global plasma performance, is discussed.« less

  20. Optimal Multi-Type Sensor Placement for Structural Identification by Static-Load Testing

    PubMed Central

    Papadopoulou, Maria; Vernay, Didier; Smith, Ian F. C.

    2017-01-01

    Assessing ageing infrastructure is a critical challenge for civil engineers due to the difficulty in the estimation and integration of uncertainties in structural models. Field measurements are increasingly used to improve knowledge of the real behavior of a structure; this activity is called structural identification. Error-domain model falsification (EDMF) is an easy-to-use model-based structural-identification methodology which robustly accommodates systematic uncertainties originating from sources such as boundary conditions, numerical modelling and model fidelity, as well as aleatory uncertainties from sources such as measurement error and material parameter-value estimations. In most practical applications of structural identification, sensors are placed using engineering judgment and experience. However, since sensor placement is fundamental to the success of structural identification, a more rational and systematic method is justified. This study presents a measurement system design methodology to identify the best sensor locations and sensor types using information from static-load tests. More specifically, three static-load tests were studied for the sensor system design using three types of sensors for a performance evaluation of a full-scale bridge in Singapore. Several sensor placement strategies are compared using joint entropy as an information-gain metric. A modified version of the hierarchical algorithm for sensor placement is proposed to take into account mutual information between load tests. It is shown that a carefully-configured measurement strategy that includes multiple sensor types and several load tests maximizes information gain. PMID:29240684

  1. The Impact of Job Involvement on Emotional Labor to Customer-Oriented Behavior: An Empirical Study of Hospital Nurses.

    PubMed

    Wang, Mei-Ling; Chang, Shu-Chen

    2016-06-01

    Healthcare is a profession that requires a high level of emotional labor (EL). Nurses provide frontline services in hospitals and thus typically experience high levels of EL. The quality of services that nurses provide impacts on how patients evaluate the service quality of hospitals. The aim of this study is to explore the relationships among EL, job involvement (JI), and customer-oriented behavior (COB) in the context of the nursing profession. The participants in this study were nurses at eight hospitals, all located in Taiwan. This study used a self-reporting questionnaire. Research data were gathered at two discrete periods (A and B). Questionnaire A collected data on EL and JI, and Questionnaire B collected data on COB. Five hundred questionnaires were sent out to qualified participants, and 472 valid questionnaires were returned. Hierarchical regression analysis was used to test the hypotheses. The expression of positive emotion (EPE) and the suppression of negative emotion (SNE) were found to positively affect the patient-oriented COB. Furthermore, the EPE was found to positively affect the task-oriented COB. In terms of the moderating effect of JI, JI was found to relate positively to the EPE, patient-oriented COB, and task-oriented COB. In addition, higher values of JI were found to weaken the relationship between the SNE and the task-oriented COB. It has become an increasingly popular practice for hospital organizations to work to promote the COB of their nursing staffs. The results of this study prove empirically that a relationship exists among EL, COB, and JI in nurses. This study contributes to the related literature, enhances the knowledge of hospital and nursing administrators with regard to EL and COB, and offers a reference for hospital managers who are responsible for designing and executing multidisciplinary programs and for managing hospital-based human resources.

  2. Extraprostatic Extension Is Extremely Rare for Contemporary Gleason Score 6 Prostate Cancer.

    PubMed

    Anderson, Blake B; Oberlin, Daniel T; Razmaria, Aria A; Choy, Bonnie; Zagaja, Gregory P; Shalhav, Arieh L; Meeks, Joshua J; Yang, Ximing J; Paner, Gladell P; Eggener, Scott E

    2017-09-01

    A significant proportion of men with Gleason score 6 (GS6) prostate cancer undergo treatment with radiation or surgery. To assess pathologic stage of pure GS6 at radical prostatectomy (RP). In the period 2003-2014, 7817 patients underwent RP at two institutions. Of 2502 patients with GS6 at surgery, 60 were identified as stage pT3a-b on initial pathologic review, 55 with pT3a (extraprostatic extension, EPE), and five with pT3b (seminal vesicle invasion; SVI). All cases of GS6 with pT3 disease underwent contemporary pathologic evaluation for Gleason grade, stage, and extent of EPE. At one institution, all GS≥7 pT3b cases were re-reviewed for downgrading. The 2014 International Society of Urological Pathology (ISUP) Gleason grading criteria and 2009 ISUP recommendations on pT3 staging were applied. Calculated incidence (%) of pT3a, pT3b, pT4, and lymph node-positive disease. Of the 60 GS6 pT3a-b cases identified in the period 2003-2014, seven (0.28% of entire GS6 cohort) with GS6 and pT3a were identified after re-review, all focal EPE. Among the re-examined cohort, no cases of GS6 with pT3b were observed. None of the 132 GS≥7 pT3b cases were downgraded to GS6. Limitations include partial embedding of specimens and separate pathologic review at each institution. In a large prostatectomy cohort, GS6 never had seminal vesicle invasion (0%) and was very rarely (0.28%) associated with extraprostatic extension. GS6 prostate cancer rarely spreads outside the prostate. A new finding in this study was that GS6 prostate cancer never spread to the seminal vesicles. Copyright © 2016 European Association of Urology. Published by Elsevier B.V. All rights reserved.

  3. Integrated lipidomics and transcriptomic analysis of peripheral blood reveals significantly enriched pathways in type 2 diabetes mellitus.

    PubMed

    Zhao, Chen; Mao, Jinghe; Ai, Junmei; Shenwu, Ming; Shi, Tieliu; Zhang, Daqing; Wang, Xiaonan; Wang, Yunliang; Deng, Youping

    2013-01-01

    Insulin resistance is a key element in the pathogenesis of type 2 diabetes mellitus. Plasma free fatty acids were assumed to mediate the insulin resistance, while the relationship between lipid and glucose disposal remains to be demonstrated across liver, skeletal muscle and blood. We profiled both lipidomics and gene expression of 144 total peripheral blood samples, 84 from patients with T2D and 60 from healthy controls. Then, factor and partial least squares models were used to perform a combined analysis of lipidomics and gene expression profiles to uncover the bioprocesses that are associated with lipidomic profiles in type 2 diabetes. According to factor analysis of the lipidomic profile, several species of lipids were found to be correlated with different phenotypes, including diabetes-related C23:2CE, C23:3CE, C23:4CE, ePE36:4, ePE36:5, ePE36:6; race-related (African-American) PI36:1; and sex-related PE34:1 and LPC18:2. The major variance of gene expression profile was not caused by known factors and no significant difference can be directly derived from differential gene expression profile. However, the combination of lipidomic and gene expression analyses allows us to reveal the correlation between the altered lipid profile with significantly enriched pathways, such as one carbon pool by folate, arachidonic acid metabolism, insulin signaling pathway, amino sugar and nucleotide sugar metabolism, propanoate metabolism, and starch and sucrose metabolism. The genes in these pathways showed a good capability to classify diabetes samples. Combined analysis of gene expression and lipidomic profiling reveals type 2 diabetes-associated lipid species and enriched biological pathways in peripheral blood, while gene expression profile does not show direct correlation. Our findings provide a new clue to better understand the mechanism of disordered lipid metabolism in association with type 2 diabetes.

  4. Hesitation and error: Does product placement in an emergency department influence hand hygiene performance?

    PubMed

    Stackelroth, Jenny; Sinnott, Michael; Shaban, Ramon Z

    2015-09-01

    Existing research has consistently demonstrated poor compliance by health care workers with hand hygiene standards. This study examined the extent to which incorrect hand hygiene occurred as a result of the inability to easily distinguish between different hand hygiene solutions placed at washbasins. A direct observational method was used using ceiling-mounted, motion-activated video camera surveillance in a tertiary referral emergency department in Australia. Data from a 24-hour period on day 10 of the recordings were collected into the Hand Hygiene-Technique Observation Tool based on Feldman's criteria as modified by Larson and Lusk. A total of 459 episodes of hand hygiene were recorded by 6 video cameras in the 24-hour period. The observed overall rate of error in this study was 6.2% (27 episodes). In addition an overall rate of hesitation was 5.8% (26 episodes). There was no statistically significant difference in error rates with the 2 hand washbasin configurations. The amelioration of causes of error and hesitation by standardization of the appearance and relative positioning of hand hygiene solutions at washbasins may translate in to improved hand hygiene behaviors. Placement of moisturizer at the washbasin may not be essential. Crown Copyright © 2015. Published by Elsevier Inc. All rights reserved.

  5. Comparison of the efficacy and technical accuracy of different rectangular collimators for intraoral radiography.

    PubMed

    Zhang, Wenjian; Abramovitch, Kenneth; Thames, Walter; Leon, Inga-Lill K; Colosi, Dan C; Goren, Arthur D

    2009-07-01

    The objective of this study was to compare the operating efficiency and technical accuracy of 3 different rectangular collimators. A full-mouth intraoral radiographic series excluding central incisor views were taken on training manikins by 2 groups of undergraduate dental and dental hygiene students. Three types of rectangular collimator were used: Type I ("free-hand"), Type II (mechanical interlocking), and Type III (magnetic collimator). Eighteen students exposed one side of the manikin with a Type I collimator and the other side with a Type II. Another 15 students exposed the manikin with Type I and Type III respectively. Type I is currently used for teaching and patient care at our institution and was considered as the control to which both Types II and III were compared. The time necessary to perform the procedure, subjective user friendliness, and the number of technique errors (placement, projection, and cone cut errors) were assessed. The Student t test or signed rank test was used to determine statistical difference (P

  6. The effects of a test-taking strategy intervention for high school students with test anxiety in advanced placement science courses

    NASA Astrophysics Data System (ADS)

    Markus, Doron J.

    Test anxiety is one of the most debilitating and disruptive factors associated with underachievement and failure in schools (Birenbaum, Menucha, Nasser, & Fadia, 1994; Tobias, 1985). Researchers have suggested that interventions that combine multiple test-anxiety reduction techniques are most effective at reducing test anxiety levels (Ergene, 2003). For the current study, involving 62 public high school students enrolled in advanced placement science courses, the researcher designed a multimodal intervention designed to reduce test anxiety. Analyses were conducted to assess the relationships among test anxiety levels, unit examination scores, and irregular multiple-choice error patterns (error clumping), as well as changes in these measures after the intervention. Results indicate significant, positive relationships between some measures of test anxiety and error clumping, as well as significant, negative relationships between test anxiety levels and student achievement. In addition, results show significant decreases in holistic measures of test anxiety among students with low anxiety levels, as well as decreases in Emotionality subscores of test anxiety among students with high levels of test anxiety. There were no significant changes over time in the Worry subscores of test anxiety. Suggestions for further research include further confirmation of the existence of error clumping, and its causal relationship with test anxiety.

  7. Students' Conceptual Change in Electricity and Magnetism Using Simulations: A Comparison of Cognitive Perturbation and Cognitive Conflict

    ERIC Educational Resources Information Center

    Dega, Bekele Gashe; Kriek, Jeanne; Mogese, Temesgen Fereja

    2013-01-01

    The purpose of this study was to investigate Ethiopian physics undergraduate students' conceptual change in the concepts of electric potential and energy (EPE) and electromagnetic induction (EMI). A quasi-experimental design was used to study the effect of cognitive perturbation using physics interactive simulations (CPS) in relation to cognitive…

  8. Spatio-Temporal Field Estimation Using Kriged Kalman Filter (KKF) with Sparsity-Enforcing Sensor Placement.

    PubMed

    Roy, Venkat; Simonetto, Andrea; Leus, Geert

    2018-06-01

    We propose a sensor placement method for spatio-temporal field estimation based on a kriged Kalman filter (KKF) using a network of static or mobile sensors. The developed framework dynamically designs the optimal constellation to place the sensors. We combine the estimation error (for the stationary as well as non-stationary component of the field) minimization problem with a sparsity-enforcing penalty to design the optimal sensor constellation in an economic manner. The developed sensor placement method can be directly used for a general class of covariance matrices (ill-conditioned or well-conditioned) modelling the spatial variability of the stationary component of the field, which acts as a correlated observation noise, while estimating the non-stationary component of the field. Finally, a KKF estimator is used to estimate the field using the measurements from the selected sensing locations. Numerical results are provided to exhibit the feasibility of the proposed dynamic sensor placement followed by the KKF estimation method.

  9. Accuracy of flat panel detector CT with integrated navigational software with and without MR fusion for single-pass needle placement.

    PubMed

    Mabray, Marc C; Datta, Sanjit; Lillaney, Prasheel V; Moore, Teri; Gehrisch, Sonja; Talbott, Jason F; Levitt, Michael R; Ghodke, Basavaraj V; Larson, Paul S; Cooke, Daniel L

    2016-07-01

    Fluoroscopic systems in modern interventional suites have the ability to perform flat panel detector CT (FDCT) with navigational guidance. Fusion with MR allows navigational guidance towards FDCT occult targets. We aim to evaluate the accuracy of this system using single-pass needle placement in a deep brain stimulation (DBS) phantom. MR was performed on a head phantom with DBS lead targets. The head phantom was placed into fixation and FDCT was performed. FDCT and MR datasets were automatically fused using the integrated guidance system (iGuide, Siemens). A DBS target was selected on the MR dataset. A 10 cm, 19 G needle was advanced by hand in a single pass using laser crosshair guidance. Radial error was visually assessed against measurement markers on the target and by a second FDCT. Ten needles were placed using CT-MR fusion and 10 needles were placed without MR fusion, with targeting based solely on FDCT and fusion steps repeated for every pass. Mean radial error was 2.75±1.39 mm as defined by visual assessment to the centre of the DBS target and 2.80±1.43 mm as defined by FDCT to the centre of the selected target point. There were no statistically significant differences in error between MR fusion and non-MR guided series. Single pass needle placement in a DBS phantom using FDCT guidance is associated with a radial error of approximately 2.5-3.0 mm at a depth of approximately 80 mm. This system could accurately target sub-centimetre intracranial lesions defined on MR. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  10. Uncertainty Analysis of Seebeck Coefficient and Electrical Resistivity Characterization

    NASA Technical Reports Server (NTRS)

    Mackey, Jon; Sehirlioglu, Alp; Dynys, Fred

    2014-01-01

    In order to provide a complete description of a materials thermoelectric power factor, in addition to the measured nominal value, an uncertainty interval is required. The uncertainty may contain sources of measurement error including systematic bias error and precision error of a statistical nature. The work focuses specifically on the popular ZEM-3 (Ulvac Technologies) measurement system, but the methods apply to any measurement system. The analysis accounts for sources of systematic error including sample preparation tolerance, measurement probe placement, thermocouple cold-finger effect, and measurement parameters; in addition to including uncertainty of a statistical nature. Complete uncertainty analysis of a measurement system allows for more reliable comparison of measurement data between laboratories.

  11. The Role of ERK Signaling in Experimental Autoimmune Encephalomyelitis

    PubMed Central

    Birkner, Katharina; Wasser, Beatrice; Loos, Julia; Plotnikov, Alexander; Seger, Rony; Zipp, Frauke; Witsch, Esther; Bittner, Stefan

    2017-01-01

    Extracellular signal-regulated kinase (ERK) signaling plays a crucial role in regulating immune cell function and has been implicated in autoimmune disorders. To date, all commercially available inhibitors of ERK target upstream components, such as mitogen-activated protein (MAP) kinase/ERK kinase (MEKs), but not ERK itself. Here, we directly inhibit nuclear ERK translocation by a novel pharmacological approach (Glu-Pro-Glu (EPE) peptide), leading to an increase in cytosolic ERK phosphorylation during T helper (Th)17 cell differentiation. This was accompanied by diminished secretion of granulocyte-macrophage colony-stimulating factor (GM-CSF), a cytokine influencing the encephalitogenicity of Th17 cells. Neither the production of the cytokine interleukin (IL)-17 nor the proliferation rate of T cells was affected by the EPE peptide. The in vivo effects of ERK inhibition were challenged in two independent variants of experimental autoimmune encephalomyelitis (EAE), an animal model of multiple sclerosis (MS). Overall, ERK inhibition had only a very minor impact on the clinical disease course of EAE. This indicates that while ERK translocation might promote encephalitogenicity in T cells in vitro by facilitating GM-CSF production, this effect is overcome in more complex in vivo animal models of central nervous system (CNS) autoimmunity. PMID:28914804

  12. Chile: educational game, "Learning about AIDS: the Responsibility of All".

    PubMed

    1993-01-01

    For more than 10 years, People's Health Education (EPES) has developed educational materials which call upon target audiences to integrate their practical experiences into a collective learning process based upon games. The methodology and materials aim to meet the needs of the most underprivileged sections of the population. EPES produced "Learning about AIDS: the responsibility of all," a game which can be used as it is or adapted to meet the needs of differing groups. The objectives of the game are to provide basic information on AIDS; to facilitate the expression of ideas, beliefs, and myths about AIDS; to promote forums for discussion in order to exchange opinions and views on sexuality and AIDS; to create awareness on how AIDS affects the community; and to create awareness of the need to prevent the disease. Played in couples to strengthen the level of interpersonal communication on such issues, the game is played because AIDS is a fact of everyday life which is affecting the community, because learning about AIDS will help people to protect themselves and their communities from the disease and groundless associated fears, and because open discussion is needed to help prevent more people from becoming infected with HIV.

  13. Inhibition properties of propolis extracts to some clinically important enzymes.

    PubMed

    Baltas, Nimet; Yildiz, Oktay; Kolayli, Sevgi

    2016-01-01

    The present study was conducted to envisage inhibition effects of propolis on the crucial enzymes, urease, xanthine oxidase (XO) and acetylcholinesterase (AChE). Some of the antioxidant properties of the propolis samples were determined using the total phenolic content (TPE) and total flavonoids in the eight different ethanolic propolis extracts (EPE) samples. Inhibition values of the enzymes were expressed as inhibition concentration (IC 50 ; mg/mL or μg/mL) causing 50% inhibition of the enzymes with donepezil, acetohydroxamic acid and allopurinol as reference inhibitors. All the propolis extracts exhibited variable inhibition effects on these enzymes, but the higher the phenolic contents the lower the inhibitions values (IC 50 = 0.074 to 1.560 mg/mL). IC 50 values of the P5 propolis sample having the highest TPE, obtained from Zonguldak, for AChE, urease and XO were 0.081 ± 0.009, 0.080 ± 0.006 and 0.074 ± 0.011 μg/mL, respectively. The EPE proved to be a good source of inhibitor agents that can be used as natural inhibitors to serve human health.

  14. Seed Placement in Permanent Breast Seed Implant Brachytherapy: Are Concerns Over Accuracy Valid?

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Morton, Daniel, E-mail: dmorton@bccancer.bc.ca; Department of Physics and Astronomy, University of Victoria, Victoria, British Columbia; Hilts, Michelle

    Purpose: To evaluate seed placement accuracy in permanent breast seed implant brachytherapy (PBSI), to identify any systematic errors and evaluate their effect on dosimetry. Methods and Materials: Treatment plans and postimplant computed tomography scans for 20 PBSI patients were spatially registered and used to evaluate differences between planned and implanted seed positions, termed seed displacements. For each patient, the mean total and directional seed displacements were determined in both standard room coordinates and in needle coordinates relative to needle insertion angle. Seeds were labeled according to their proximity to the anatomy within the breast, to evaluate the influence of anatomicmore » regions on seed placement. Dosimetry within an evaluative target volume (seroma + 5 mm), skin, breast, and ribs was evaluated to determine the impact of seed placement on the treatment. Results: The overall mean (±SD) difference between implanted and planned positions was 9 ± 5 mm for the aggregate seed population. No significant systematic directional displacements were observed for this whole population. However, for individual patients, systematic displacements were observed, implying that intrapatient offsets occur during the procedure. Mean displacements for seeds in the different anatomic areas were not found to be significantly different from the mean for the entire seed population. However, small directional trends were observed within the anatomy, potentially indicating some bias in the delivery. Despite observed differences between the planned and implanted seed positions, the median (range) V{sub 90} for the 20 patients was 97% (66%-100%), and acceptable dosimetry was achieved for critical structures. Conclusions: No significant trends or systematic errors were observed in the placement of seeds in PBSI, including seeds implanted directly into the seroma. Recorded seed displacements may be related to intrapatient setup adjustments. Despite observed seed displacements, acceptable postimplant dosimetry was achieved.« less

  15. Percutaneous spinal fixation simulation with virtual reality and haptics.

    PubMed

    Luciano, Cristian J; Banerjee, P Pat; Sorenson, Jeffery M; Foley, Kevin T; Ansari, Sameer A; Rizzi, Silvio; Germanwala, Anand V; Kranzler, Leonard; Chittiboina, Prashant; Roitberg, Ben Z

    2013-01-01

    In this study, we evaluated the use of a part-task simulator with 3-dimensional and haptic feedback as a training tool for percutaneous spinal needle placement. To evaluate the learning effectiveness in terms of entry point/target point accuracy of percutaneous spinal needle placement on a high-performance augmented-reality and haptic technology workstation with the ability to control the duration of computer-simulated fluoroscopic exposure, thereby simulating an actual situation. Sixty-three fellows and residents performed needle placement on the simulator. A virtual needle was percutaneously inserted into a virtual patient's thoracic spine derived from an actual patient computed tomography data set. Ten of 126 needle placement attempts by 63 participants ended in failure for a failure rate of 7.93%. From all 126 needle insertions, the average error (15.69 vs 13.91), average fluoroscopy exposure (4.6 vs 3.92), and average individual performance score (32.39 vs 30.71) improved from the first to the second attempt. Performance accuracy yielded P = .04 from a 2-sample t test in which the rejected null hypothesis assumes no improvement in performance accuracy from the first to second attempt in the test session. The experiments showed evidence (P = .04) of performance accuracy improvement from the first to the second percutaneous needle placement attempt. This result, combined with previous learning retention and/or face validity results of using the simulator for open thoracic pedicle screw placement and ventriculostomy catheter placement, supports the efficacy of augmented reality and haptics simulation as a learning tool.

  16. Method for measuring target rotation angle by theodolites

    NASA Astrophysics Data System (ADS)

    Sun, Zelin; Wang, Zhao; Zhai, Huanchun; Yang, Xiaoxu

    2013-05-01

    To overcome the disadvantage of the current measurement methods using theodolites in an environment with shock and long working hours and so on, this paper proposes a new method for 3D coordinate measurement that is based on an immovable measuring coordinate system. According to the measuring principle, the mathematics model is established and the measurement uncertainty is analysed. The measurement uncertainty of the new method is a function of the theodolite observation angles and their uncertainty, and can be reduced by optimizing the theodolites’ placement. Compared to other methods, this method allows the theodolite positions to be changed in the measuring process, and mutual collimation between the theodolites is not required. The experimental results show that the measurement model and the optimal placement principle are correct, and the measurement error is less than 0.01° after optimizing the theodolites’ placement.

  17. Accuracy of Novel Computed Tomography-Guided Frameless Stereotactic Drilling and Catheter System in Human Cadavers.

    PubMed

    Sankey, Eric W; Butler, Eric; Sampson, John H

    2017-10-01

    To evaluate accuracy of a computed tomography (CT)-guided frameless stereotactic drilling and catheter system. A prospective, single-arm study was performed using human cadaver heads to evaluate placement accuracy of a novel, flexible intracranial catheter and stabilizing bone anchor system and drill kit. There were 20 catheter placements included in the analysis. The primary endpoint was accuracy of catheter tip location on intraoperative CT. Secondary endpoints included target registration error and entry and target point error before and after drilling. Measurements are reported as mean ± SD (median, range). Target registration error was 0.46 mm ± 0.26 (0.50 mm, -1.00 to 1.00 mm). Two (10%) target point trajectories were negatively impacted by drilling. Intracranial catheter depth was 59.8 mm ± 9.4 (60.5 mm, 38.0-80.0 mm). Drilling angle was 22° ± 9 (21°, 7°-45°). Deviation between planned and actual entry point on CT was 1.04 mm ± 0.38 (1.00 mm, 0.40-2.00 mm). Deviation between planned and actual target point on CT was 1.60 mm ± 0.98 (1.40 mm, 0.40-4.00 mm). No correlation was observed between intracranial catheter depth and target point deviation (accuracy) (Pearson coefficient 0.018) or between technician experience and accuracy (Pearson coefficient 0.020). There was no significant difference in accuracy with trajectories performed for different cadaver heads (P = 0.362). Highly accurate catheter placement is achievable using this novel flexible catheter and bone anchor system placed via frameless stereotaxy, with an average deviation between planned and actual target point of 1.60 mm ± 0.98 (1.40 mm, 0.40-4.00 mm). Copyright © 2017 Elsevier Inc. All rights reserved.

  18. Identification of Microbial Gene Biomarkers for in situ RDX Biodegradation

    DTIC Science & Technology

    2012-12-01

    Additional research is required to determine reliable guidelines to inform site managers of specific field concentrations of ammonium and nitrate...Mrs. Cynthia L. Price, Research Biologist, EPED, EL, ERDC; Dr. Rick Arnseth, Project Manager / Geochemist, Tetra Tech Inc., Oak Ridge, TN; and...a biomarker of RDX degradation, as it will also be necessary for bioremediation site managers to measure soil and groundwater concentra- tions for

  19. Surface characterization of low-temperature grown yttrium oxide

    NASA Astrophysics Data System (ADS)

    Krawczyk, Mirosław; Lisowski, Wojciech; Pisarek, Marcin; Nikiforow, Kostiantyn; Jablonski, Aleksander

    2018-04-01

    The step-by-step growth of yttrium oxide layer was controlled in situ using X-ray photoelectron spectroscopy (XPS). The O/Y atomic concentration (AC) ratio in the surface layer of finally oxidized Y substrate was found to be equal to 1.48. The as-grown yttrium oxide layers were then analyzed ex situ using combination of Auger electron spectroscopy (AES), elastic-peak electron spectroscopy (EPES) and scanning electron microscopy (SEM) in order to characterize their surface chemical composition, electron transport phenomena and surface morphology. Prior to EPES measurements, the Y oxide surface was pre-sputtered by 3 kV argon ions, and the resulting AES-derived composition was found to be Y0.383O0.465C0.152 (O/Y AC ratio of 1.21). The SEM images revealed different surface morphology of sample before and after Ar sputtering. The oxide precipitates were observed on the top of un-sputtered Y oxide layer, whereas the oxide growth at the Ar ion-sputtered surface proceeded along defects lines normal to the layer plane. The inelastic mean free path (IMFP) characterizing electron transport was evaluated as a function of energy in the range of 0.5-2 keV from the EPES method. Two reference materials (Ni and Au) were used in these measurements. Experimental IMFPs determined for the Y0.383O0.465C0.152 and Y2O3 surface compositions, λ, were uncorrected for surface excitations and approximated by the simple function λ = kEp at electron energies E between 500 eV and 2000 eV, where k and p were fitted parameters. These values were also compared with IMFPs resulting from the TPP-2 M predictive equation for both oxide compositions. The fitted functions were found to be reasonably consistent with the measured and predicted IMFPs. In both cases, the average value of the mean percentage deviation from the fits varied between 5% and 37%. The IMFPs measured for Y0.383O0.465C0.152 surface composition were found to be similar to the IMFPs for Y2O3.

  20. Injuries in children with extra physical education in primary schools.

    PubMed

    Rexen, Christina Trifonov; Andersen, Lars Bo; Ersbøll, Annette Kjær; Jespersen, Eva; Franz, Claudia; Wedderkopp, Niels

    2014-04-01

    (1) Examine the influence of extra physical education (EPE) on the number of musculoskeletal injuries in public schools accounting for organized sports participation (OSP) outside school. (2) Examine the major injury subgroup: growth-related overuse (GRO) through the overuse-related injury group. A longitudinal controlled school-based study among Danish public schools. At baseline, 1216 children participated age 6.2-12.4 yr. Six schools (701 children) with EPE and four control schools (515 children) were followed up with weekly automated mobile phone text messages for information on musculoskeletal problems and OSP. Health care personnel diagnosed the children according to the World Health Organization's International Classification of Diseases, Tenth Revision. Data were analyzed using a two-part zero-inflated negative binomial (ZINB) regression model. School type had no influence on the odds of sustaining an injury but increased the probability of sustaining a higher injury count for children with injuries, with total injuries by a factor of 1.29 (95% confidence interval [CI] = 1.07-1.56), overuse by a factor of 1.29 (95% CI = 1.06-1.55), and GRO by a factor of 1.38 (95% CI = 1.02-1.80). Weekly mean OSP decreased the odds of belonging to the group of children with no injuries, by a factor of 0.29 (95% CI = 0.14-0.58), 0.26 (95% CI = 0.14-0.48), and 0.17 (95% CI = 0.06-0.52) for total, overuse, and GRO, respectively. OSP also increased the probability of sustaining a higher injury count for children with injuries by a factor of 1.11 (95% CI = 1.02-1.22), 1.10 (95% CI = 1.00-1.22), and 1.14 (95% CI = 1.00-1.30), respectively. Children enrolled in EPE schools with high OSP have the highest odds of injury and a high probability of sustaining a higher injury count compared to their peers at schools with normal PE. Special attention should be assigned to these children during compulsory PE.

  1. A simple customized surgical guide for orthodontic miniplates with tube.

    PubMed

    Paek, Janghyun; Su, Ming-Jeaun; Kwon, Soon-Yong; Kim, Seong-Hun; Chung, Kyu-Rhim; Nelson, Gerald

    2012-09-01

    This article reports the use of a customized surgical guide for simple and precise C-tube plate placement with minimized incision. Patients who were planning to have orthodontic miniplate treatment because of narrow interradicular space were recruited for this study. A combined silicone and stainless steel wire surgical guide for the C-tube was fabricated on the cast model. The taller wire of the positioning guide is used to accurately start the incision. The incision guide-wire position is verified by placing the miniplate on the coronal horizontal wire to confirm that the incision will coordinate with the screw holes. Because the miniplate is firmly held in place, there is no risk of the miniplate anchoring screws (diameter, 1.5 mm; length, 4 mm) sliding on the bone surface during placement with a manual hand driver. The surgical guide was placed on the clinical site, and it allowed precise placement of the miniplate with minimum incision and preventing from slippage or path-of-insertion angulation errors that might interfere with accurate placement. Customized surgical guide enables precise planning for miniplate positions in anatomically complex sites.

  2. Splash: a software tool for stereotactic planning of recording chamber placement and electrode trajectories.

    PubMed

    Sperka, Daniel J; Ditterich, Jochen

    2011-01-01

    While computer-aided planning of human neurosurgeries is becoming more and more common, animal researchers still largely rely on paper atlases for planning their approach before implanting recording chambers to perform invasive recordings of neural activity, which makes this planning process tedious and error-prone. Here we present SPLASh (Stereotactic PLAnning Software), an interactive software tool for the stereotactic planning of recording chamber placement and electrode trajectories. SPLASh has been developed for monkey cortical recordings and relies on a combination of structural MRIs and electronic brain atlases. Since SPLASh is based on the neuroanatomy software Caret, it should also be possible to use it for other parts of the brain or other species for which Caret atlases are available. The tool allows the user to interactively evaluate different possible placements of recording chambers and to simulate electrode trajectories.

  3. Splash: A Software Tool for Stereotactic Planning of Recording Chamber Placement and Electrode Trajectories

    PubMed Central

    Sperka, Daniel J.; Ditterich, Jochen

    2011-01-01

    While computer-aided planning of human neurosurgeries is becoming more and more common, animal researchers still largely rely on paper atlases for planning their approach before implanting recording chambers to perform invasive recordings of neural activity, which makes this planning process tedious and error-prone. Here we present SPLASh (Stereotactic PLAnning Software), an interactive software tool for the stereotactic planning of recording chamber placement and electrode trajectories. SPLASh has been developed for monkey cortical recordings and relies on a combination of structural MRIs and electronic brain atlases. Since SPLASh is based on the neuroanatomy software Caret, it should also be possible to use it for other parts of the brain or other species for which Caret atlases are available. The tool allows the user to interactively evaluate different possible placements of recording chambers and to simulate electrode trajectories. PMID:21472085

  4. MO-FG-BRA-06: Electromagnetic Beacon Insertion in Lung Cancer Patients and Resultant Surrogacy Errors for Dynamic MLC Tumour Tracking

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hardcastle, N; Booth, J; Caillet, V

    Purpose: To assess endo-bronchial electromagnetic beacon insertion and to quantify the geometric accuracy of using beacons as a surrogate for tumour motion in real-time multileaf collimator (MLC) tracking of lung tumours. Methods: The LIGHT SABR trial is a world-first clinical trial in which the MLC leaves move with lung tumours in real time on a standard linear accelerator. Tracking is performed based on implanted electromagnetic beacons (CalypsoTM, Varian Medical Systems, USA) as a surrogate for tumour motion. Five patients have been treated and have each had three beacons implanted endo-bronchially under fluoroscopic guidance. The centre of mass (C.O.M) has beenmore » used to adapt the MLC in real-time. The geometric error in using the beacon C.O.M as a surrogate for tumour motion was measured by measuring the tumour and beacon C.O.M in all phases of the respiratory cycle of a 4DCT. The surrogacy error was defined as the difference in beacon and tumour C.O.M relative to the reference phase (maximum exhale). Results: All five patients have had three beacons successfully implanted with no migration between simulation and end of treatment. Beacon placement relative to tumour C.O.M varied from 14 to 74 mm and in one patient spanned two lobes. Surrogacy error was measured in each patient on the simulation 4DCT and ranged from 0 to 3 mm. Surrogacy error as measured on 4DCT was subject to artefacts in mid-ventilation phases. Surrogacy error was a function of breathing phase and was typically larger at maximum inhale. Conclusion: Beacon placement and thus surrogacy error is a major component of geometric uncertainty in MLC tracking of lung tumours. Surrogacy error must be measured on each patient and incorporated into margin calculation. Reduction of surrogacy error is limited by airway anatomy, however should be taken into consideration when performing beacon insertion and planning. This research is funded by Varian Medical Systems via a collaborative research agreement.« less

  5. Risk behaviours for organism transmission in health care delivery-A two month unstructured observational study.

    PubMed

    Lindberg, Maria; Lindberg, Magnus; Skytt, Bernice

    2017-05-01

    Errors in infection control practices risk patient safety. The probability for errors can increase when care practices become more multifaceted. It is therefore fundamental to track risk behaviours and potential errors in various care situations. The aim of this study was to describe care situations involving risk behaviours for organism transmission that could lead to subsequent healthcare-associated infections. Unstructured nonparticipant observations were performed at three medical wards. Healthcare personnel (n=27) were shadowed, in total 39h, on randomly selected weekdays between 7:30 am and 12 noon. Content analysis was used to inductively categorize activities into tasks and based on the character into groups. Risk behaviours for organism transmission were deductively classified into types of errors. Multiple response crosstabs procedure was used to visualize the number and proportion of errors in tasks. One-Way ANOVA with Bonferroni post Hoc test was used to determine differences among the three groups of activities. The qualitative findings gives an understanding of that risk behaviours for organism transmission goes beyond the five moments of hand hygiene and also includes the handling and placement of materials and equipment. The tasks with the highest percentage of errors were; 'personal hygiene', 'elimination' and 'dressing/wound care'. The most common types of errors in all identified tasks were; 'hand disinfection', 'glove usage', and 'placement of materials'. Significantly more errors (p<0.0001) were observed the more multifaceted (single, combined or interrupted) the activity was. The numbers and types of errors as well as the character of activities performed in care situations described in this study confirm the need to improve current infection control practices. It is fundamental that healthcare personnel practice good hand hygiene however effective preventive hygiene is complex in healthcare activities due to the multifaceted care situations, especially when activities are interrupted. A deeper understanding of infection control practices that goes beyond the sense of security by means of hand disinfection and use of gloves is needed as materials and surfaces in the care environment might be contaminated and thus pose a risk for organism transmission. Copyright © 2017 Elsevier Ltd. All rights reserved.

  6. Speech therapy for errors secondary to cleft palate and velopharyngeal dysfunction.

    PubMed

    Kummer, Ann W

    2011-05-01

    Individuals with a history of cleft lip/palate or velopharyngeal dysfunction may demonstrate any combination of speech sound errors, hypernasality, and nasal emission. Speech sound distortion can also occur due to other structural anomalies, including malocclusion. Whenever there are structural anomalies, speech can be affected by obligatory distortions or compensatory errors. Obligatory distortions (including hypernasality due to velopharyngeal insufficiency) are caused by abnormal structure and not by abnormal function. Therefore, surgery or other forms of physical management are needed for correction. In contrast, speech therapy is indicated for compensatory articulation productions where articulation placement is changed in response to the abnormal structure. Speech therapy is much more effective if it is done after normalization of the structure. When speech therapy is appropriate, the techniques involve methods to change articulation placement using standard articulation therapy principles. Oral-motor exercises, including the use of blowing and sucking, are never indicated to improve velopharyngeal function. The purpose of this article is to provide information regarding when speech therapy is appropriate for individuals with a history of cleft palate or other structural anomalies and when physical management is needed. In addition, some specific therapy techniques are offered for the elimination of common compensatory articulation productions. © Thieme Medical Publishers.

  7. Generation of Higher Order Modes in a Rectangular Duct

    NASA Technical Reports Server (NTRS)

    Gerhold, Carl H.; Cabell, Randolph H.; Brown, Donald E.

    2004-01-01

    Advanced noise control methodologies to reduce sound emission from aircraft engines take advantage of the modal structure of the noise in the duct. This noise is caused by the interaction of rotor wakes with downstream obstructions such as exit guide vanes. Mode synthesis has been accomplished in circular ducts and current active noise control work has made use of this capability to cancel fan noise. The goal of the current effort is to examine the fundamental process of higher order mode propagation through an acoustically treated, curved duct. The duct cross-section is rectangular to permit greater flexibility in representation of a range of duct curvatures. The work presented is the development of a feedforward control system to generate a user-specified modal pattern in the duct. The multiple-error, filtered-x LMS algorithm is used to determine the magnitude and phase of signal input to the loudspeakers to produce a desired modal pattern at a set of error microphones. Implementation issues, including loudspeaker placement and error microphone placement, are discussed. Preliminary results from a 9-3/8 inch by 21 inch duct, using 12 loudspeakers and 24 microphones, are presented. These results demonstrate the ability of the control system to generate a user-specified mode while suppressing undesired modes.

  8. The School-Based Multidisciplinary Team and Nondiscriminatory Assessment.

    ERIC Educational Resources Information Center

    Pfeiffer, Steven I.

    The potential of multidisciplinary teams to control for possible errors in diagnosis, classification, and placement and to provide a vehicle for ensuring effective outcomes of diagnostic practices is illustrated. The present functions of the school-based multidisciplinary team (also called, for example, assessment team, child study team, placement…

  9. Investigation of the Use of Geobags to Immobilize Submerged Munitions: A Report on the Concept, Development, and Testing

    DTIC Science & Technology

    2013-09-01

    Halls Ferry Road; Bldg 3270; RM 1810 Vicksburg, MS 39180 Raymond S. Chapman Coastal and Hydraulics Laboratory U.S. Army Engineer Research and...11  Figure 6. Olmsted 1:5 scale hydraulic flume, Phase 2 test bed...Bailey, Environmental Engineering Branch (EEB) of EPED; Andy Martin, EEB; Dr. Ray Chapman, ERDC Coastal and Hydraulics Laboratory (CHL); and Pam

  10. Highly sensitive immunoassay of protein molecules based on single nanoparticle fluorescence detection in a nanowell

    NASA Astrophysics Data System (ADS)

    Han, Jin-Hee; Kim, Hee-Joo; Lakshmana, Sudheendra; Gee, Shirley J.; Hammock, Bruce D.; Kennedy, Ian M.

    2011-03-01

    A nanoarray based-single molecule detection system was developed for detecting proteins with extremely high sensitivity. The nanoarray was able to effectively trap nanoparticles conjugated with biological sample into nanowells by integrating with an electrophoretic particle entrapment system (EPES). The nanoarray/EPES is superior to other biosensor using immunoassays in terms of saving the amounts of biological solution and enhancing kinetics of antibody binding due to reduced steric hindrance from the neighboring biological molecules. The nanoarray patterned onto a layer of PMMA and LOL on conductive and transparent indium tin oxide (ITO)-glass slide by using e-beam lithography. The suspension of 500 nm-fluorescent (green emission)-carboxylated polystyrene (PS) particles coated with protein-A followed by BDE 47 polyclonal antibody was added to the chip that was connected to the positive voltage. The droplet was covered by another ITO-coated-glass slide and connected to a ground terminal. After trapping the particles into the nanowells, the solution of different concentrations of anti-rabbit- IgG labeled with Alexa 532 was added for an immunoassay. A single molecule detection system could quantify the anti-rabbit IgG down to atto-mole level by counting photons emitted from the fluorescent dye bound to a single nanoparticle in a nanowell.

  11. Studies of the pedestal structure and inter-ELM pedestal evolution in JET with the ITER-like wall

    NASA Astrophysics Data System (ADS)

    Maggi, C. F.; Frassinetti, L.; Horvath, L.; Lunniss, A.; Saarelma, S.; Wilson, H.; Flanagan, J.; Leyland, M.; Lupelli, I.; Pamela, S.; Urano, H.; Garzotti, L.; Lerche, E.; Nunes, I.; Rimini, F.; Contributors, JET

    2017-11-01

    The pedestal structure of type I ELMy H-modes has been analysed for JET with the ITER-like Wall (JET-ILW). The electron pressure pedestal width is independent of ρ * and increases proportionally to  √β pol,PED. Additional broadening of the width is observed, at constant β pol, PED, with increasing ν * and/or neutral gas injection and the contribution of atomic physics effects in setting the pedestal width cannot as yet be ruled out. Neutral penetration alone does not determine the shape of the edge density profile in JET-ILW. The ratio of electron density to electron temperature scale lengths in the edge transport barrier region, η e, is of order 2-3 within experimental uncertainties. Existing understanding, represented in the stationary linear peeling-ballooning mode stability and the EPED pedestal structure models, is extended to the dynamic evolution between ELM crashes in JET-ILW, in order to test the assumptions underlying these two models. The inter-ELM temporal evolution of the pedestal structure in JET-ILW is not unique, but depends on discharge conditions, such as heating power and gas injection levels. The strong reduction in p e,PED with increasing D 2 gas injection at high power is primarily due to clamping of \

  12. Multi-rater Agreement in the Assessment of Anterior Cruciate Ligament Reconstruction Failure. A Radiographic and Video Analysis of the MARS Cohort

    PubMed Central

    Matava, Matthew J.; Arciero, Robert A.; Baumgarten, Keith M.; Carey, James L.; DeBerardino, Thomas M.; Hame, Sharon L.; Hannafin, Jo A.; Miller, Bruce S.; Nissen, Carl W.; Taft, Timothy N.; Wolf, Brian R.; Wright, Rick W.

    2015-01-01

    Background ACL reconstruction failure occurs in up to 10% of cases. Technical errors are considered the most common cause of graft failure despite the absence of validated studies. There is limited data regarding the agreement among orthopedic surgeons in terms of the etiology of primary ACL reconstruction failure and accuracy of graft tunnel placement. Purpose The purpose of this study is to test the hypothesis that experienced knee surgeons have a high level of inter-observer reliability in the agreement of the etiology of the primary ACL reconstruction failure, anatomical graft characteristics, tunnel placement. Methods Twenty cases of revision ACL reconstruction were randomly selected from the MARS database. Each case included the patient's history, standardized radiographs, and a concise 30-second arthroscopic video taken at the time of revision demonstrating the graft remnant and location of the tunnel apertures. 10 MARS surgeons not involved with the primary surgery reviewed all 20 cases. Each surgeon completed a two-part questionnaire dealing with each surgeon's training and practice as well as the placement of the femoral and tibial tunnels, condition of the primary graft, and the surgeon's opinion as to the etiology of graft failure. Inter-rater agreement was determined for each question. Inter-rater agreement was determined for each question with the kappa coefficient and prevalence adjusted bias adjusted kappa (PABAK). Results The 10 reviewers were in practice an average of 14 years. All performed at least 25 ACL reconstructions per year and 9 were fellowship-trained in sports medicine. There was wide variability in agreement among knee experts as to the specific etiology of ACL graft failure. When specifically asked about technical error as the cause for failure, inter-observer agreement was only slight (prevalence adjusted bias adjusted kappa [PABAK]: 0.26). There was fair overall agreement on ideal femoral tunnel placement (PABAK: 0.55), but only slight agreement whether a femoral tunnel was too anterior (PABAK: 0.24) and fair agreement whether it was too vertical (PABAK: 0.46). There was poor overall agreement for ideal tibial tunnel placement (PABAK: 0.17). Conclusion This study suggests that more objective criteria are needed to accurately determine the etiology of primary ACL graft failure as well as the ideal femoral and tibial tunnel placement in patients undergoing revision ACL reconstruction. PMID:25537942

  13. Design and simulation of sensor networks for tracking Wifi users in outdoor urban environments

    NASA Astrophysics Data System (ADS)

    Thron, Christopher; Tran, Khoi; Smith, Douglas; Benincasa, Daniel

    2017-05-01

    We present a proof-of-concept investigation into the use of sensor networks for tracking of WiFi users in outdoor urban environments. Sensors are fixed, and are capable of measuring signal power from users' WiFi devices. We derive a maximum likelihood estimate for user location based on instantaneous sensor power measurements. The algorithm takes into account the effects of power control, and is self-calibrating in that the signal power model used by the location algorithm is adjusted and improved as part of the operation of the network. Simulation results to verify the system's performance are presented. The simulation scenario is based on a 1.5 km2 area of lower Manhattan, The self-calibration mechanism was verified for initial rms (root mean square) errors of up to 12 dB in the channel power estimates: rms errors were reduced by over 60% in 300 track-hours, in systems with limited power control. Under typical operating conditions with (without) power control, location rms errors are about 8.5 (5) meters with 90% accuracy within 9 (13) meters, for both pedestrian and vehicular users. The distance error distributions for smaller distances (<30 m) are well-approximated by an exponential distribution, while the distributions for large distance errors have fat tails. The issue of optimal sensor placement in the sensor network is also addressed. We specify a linear programming algorithm for determining sensor placement for networks with reduced number of sensors. In our test case, the algorithm produces a network with 18.5% fewer sensors with comparable accuracy estimation performance. Finally, we discuss future research directions for improving the accuracy and capabilities of sensor network systems in urban environments.

  14. Numerical simulations to assess the tracer dilution method for measurement of landfill methane emissions.

    PubMed

    Taylor, Diane M; Chow, Fotini K; Delkash, Madjid; Imhoff, Paul T

    2016-10-01

    Landfills are a significant contributor to anthropogenic methane emissions, but measuring these emissions can be challenging. This work uses numerical simulations to assess the accuracy of the tracer dilution method, which is used to estimate landfill emissions. Atmospheric dispersion simulations with the Weather Research and Forecast model (WRF) are run over Sandtown Landfill in Delaware, USA, using observation data to validate the meteorological model output. A steady landfill methane emissions rate is used in the model, and methane and tracer gas concentrations are collected along various transects downwind from the landfill for use in the tracer dilution method. The calculated methane emissions are compared to the methane emissions rate used in the model to find the percent error of the tracer dilution method for each simulation. The roles of different factors are examined: measurement distance from the landfill, transect angle relative to the wind direction, speed of the transect vehicle, tracer placement relative to the hot spot of methane emissions, complexity of topography, and wind direction. Results show that percent error generally decreases with distance from the landfill, where the tracer and methane plumes become well mixed. Tracer placement has the largest effect on percent error, and topography and wind direction both have significant effects, with measurement errors ranging from -12% to 42% over all simulations. Transect angle and transect speed have small to negligible effects on the accuracy of the tracer dilution method. These tracer dilution method simulations provide insight into measurement errors that might occur in the field, enhance understanding of the method's limitations, and aid interpretation of field data. Copyright © 2016 Elsevier Ltd. All rights reserved.

  15. Improved accuracy of ultrasound-guided therapies using electromagnetic tracking: in-vivo speed of sound measurements

    NASA Astrophysics Data System (ADS)

    Samboju, Vishal; Adams, Matthew; Salgaonkar, Vasant; Diederich, Chris J.; Cunha, J. Adam M.

    2017-02-01

    The speed of sound (SOS) for ultrasound devices used for imaging soft tissue is often calibrated to water, 1540 m/s1 , despite in-vivo soft tissue SOS varying from 1450 to 1613 m/s2 . Images acquired with 1540 m/s and used in conjunction with stereotactic external coordinate systems can thus result in displacement errors of several millimeters. Ultrasound imaging systems are routinely used to guide interventional thermal ablation and cryoablation devices, or radiation sources for brachytherapy3 . Brachytherapy uses small radioactive pellets, inserted interstitially with needles under ultrasound guidance, to eradicate cancerous tissue4 . Since the radiation dose diminishes with distance from the pellet as 1/r2 , imaging uncertainty of a few millimeters can result in significant erroneous dose delivery5,6. Likewise, modeling of power deposition and thermal dose accumulations from ablative sources are also prone to errors due to placement offsets from SOS errors7 . This work presents a method of mitigating needle placement error due to SOS variances without the need of ionizing radiation2,8. We demonstrate the effects of changes in dosimetry in a prostate brachytherapy environment due to patientspecific SOS variances and the ability to mitigate dose delivery uncertainty. Electromagnetic (EM) sensors embedded in the brachytherapy ultrasound system provide information regarding 3D position and orientation of the ultrasound array. Algorithms using data from these two modalities are used to correct bmode images to account for SOS errors. While ultrasound localization resulted in >3 mm displacements, EM resolution was verified to <1 mm precision using custom-built phantoms with various SOS, showing 1% accuracy in SOS measurement.

  16. Colorimetric carbon dioxide detector to determine accidental tracheal feeding tube placement.

    PubMed

    Howes, Daniel W; Shelley, Eric S; Pickett, William

    2005-04-01

    To determine the accuracy of colorimetric CO2 detection compared to the reference standard two-step radiological confirmation of feeding tube position. A prospective study was conducted with patients presenting to a 21-bed medical-surgical intensive care unit. An adapter was developed using an endotracheal tube adapter to connect a colorimetric CO2 detector to a feeding tube in an airtight manner. In part I of the study a feeding tube connected to the colorimeter was inserted into the endotracheal tubes of ten ventilated patients to test the device's ability to detect tracheal placement. In part II patients undergoing feeding tube insertion had tube position confirmed with the colorimeter as well as the reference standard two-step x-ray. In phase I the colorimeter correctly identified tracheal placement in all ten patients. In phase II 93/100 procedures ultimately were eligible; the colorimeter had a sensitivity of 0.88 (95% confidence interval: 0.65-1.00) and specificity of 0.99 (0.97-1.00). The device missed one of the eight tracheal placements. Agreement between the colorimeter and two-step x-ray interpretations was excellent (Kappa 0.86; standard error 0.10). We describe a novel, convenient method to confirm esophageal feeding tube placement. The device is easily assembled and inexpensive, but should not be reused. Colorimetric determination of tracheal feeding tube placement with this device has excellent agreement with the reference standard two-step radiological technique.

  17. Strategic Use of Microscrews for Enhancing the Accuracy of Computer-Guided Implant Surgery in Fully Edentulous Arches: A Case History Report.

    PubMed

    Lee, Du-Hyeong

    Implant guide systems can be classified by their supporting structure as tooth-, mucosa-, or bone-supported. Mucosa-supported guides for fully edentulous arches show lower accuracy in implant placement because of errors in image registration and guide positioning. This article introduces the application of a novel microscrew system for computer-aided implant surgery. This technique can markedly improve the accuracy of computer-guided implant surgery in fully edentulous arches by eliminating errors from image fusion and guide positioning.

  18. Optimal sensor placement for spatial lattice structure based on genetic algorithms

    NASA Astrophysics Data System (ADS)

    Liu, Wei; Gao, Wei-cheng; Sun, Yi; Xu, Min-jian

    2008-10-01

    Optimal sensor placement technique plays a key role in structural health monitoring of spatial lattice structures. This paper considers the problem of locating sensors on a spatial lattice structure with the aim of maximizing the data information so that structural dynamic behavior can be fully characterized. Based on the criterion of optimal sensor placement for modal test, an improved genetic algorithm is introduced to find the optimal placement of sensors. The modal strain energy (MSE) and the modal assurance criterion (MAC) have been taken as the fitness function, respectively, so that three placement designs were produced. The decimal two-dimension array coding method instead of binary coding method is proposed to code the solution. Forced mutation operator is introduced when the identical genes appear via the crossover procedure. A computational simulation of a 12-bay plain truss model has been implemented to demonstrate the feasibility of the three optimal algorithms above. The obtained optimal sensor placements using the improved genetic algorithm are compared with those gained by exiting genetic algorithm using the binary coding method. Further the comparison criterion based on the mean square error between the finite element method (FEM) mode shapes and the Guyan expansion mode shapes identified by data-driven stochastic subspace identification (SSI-DATA) method are employed to demonstrate the advantage of the different fitness function. The results showed that some innovations in genetic algorithm proposed in this paper can enlarge the genes storage and improve the convergence of the algorithm. More importantly, the three optimal sensor placement methods can all provide the reliable results and identify the vibration characteristics of the 12-bay plain truss model accurately.

  19. Comparison of Deep Brain Stimulation Lead Targeting Accuracy and Procedure Duration between 1.5- and 3-Tesla Interventional Magnetic Resonance Imaging Systems: An Initial 12-Month Experience.

    PubMed

    Southwell, Derek G; Narvid, Jared A; Martin, Alastair J; Qasim, Salman E; Starr, Philip A; Larson, Paul S

    2016-01-01

    Interventional magnetic resonance imaging (iMRI) allows deep brain stimulator lead placement under general anesthesia. While the accuracy of lead targeting has been described for iMRI systems utilizing 1.5-tesla magnets, a similar assessment of 3-tesla iMRI procedures has not been performed. To compare targeting accuracy, the number of lead targeting attempts, and surgical duration between procedures performed on 1.5- and 3-tesla iMRI systems. Radial targeting error, the number of targeting attempts, and procedure duration were compared between surgeries performed on 1.5- and 3-tesla iMRI systems (SmartFrame and ClearPoint systems). During the first year of operation of each system, 26 consecutive leads were implanted using the 1.5-tesla system, and 23 consecutive leads were implanted using the 3-tesla system. There was no significant difference in radial error (Mann-Whitney test, p = 0.26), number of lead placements that required multiple targeting attempts (Fisher's exact test, p = 0.59), or bilateral procedure durations between surgeries performed with the two systems (p = 0.15). Accurate DBS lead targeting can be achieved with iMRI systems utilizing either 1.5- or 3-tesla magnets. The use of a 3-tesla magnet, however, offers improved visualization of the target structures and allows comparable accuracy and efficiency of placement at the selected targets. © 2016 S. Karger AG, Basel.

  20. Brain Research: The Necessity for Separating Sites, Actions and Functions.

    ERIC Educational Resources Information Center

    Meeker, Mary

    Educators, as applied scientists, must work in partnership with investigative scientists who are researching brain functions in order to reach a better understanding of gifted students and students who are intelligent but do not learn. Improper understanding of brain functions can cause gross errors in educational placement. Until recently, the…

  1. The AP Descriptive Chemistry Question: Student Errors

    ERIC Educational Resources Information Center

    Crippen, Kent; Brooks, David W.

    2005-01-01

    For over a decade, the authors have been involved in a design theory experiment providing software for high school students preparing for the descriptive question on the Advanced Placement (AP) chemistry examination. Since 1997, the software has been available as a Web site offering repeatable practice. This study describes a 4-year project during…

  2. Investigating the Retention and Time Course of Phonotactic Constraint Learning from Production Experience

    ERIC Educational Resources Information Center

    Warker, Jill A.

    2013-01-01

    Adults can rapidly learn artificial phonotactic constraints such as /"f"/ "occurs only at the beginning of syllables" by producing syllables that contain those constraints. This implicit learning is then reflected in their speech errors. However, second-order constraints in which the placement of a phoneme depends on another…

  3. New York Bight Study. Report 2, Development and Application of a Eutrophication/General Water Quality Model

    DTIC Science & Technology

    1994-04-01

    results 0 0 and provided direct superson. General supervision was provided by Mr. Donald L. Robey, Chief, EPED, and Dr. dmin Harison , Chief, EL. This...were thus completely dependent upon transport and ChWW 5 App5 • PAN& 41 0 C@M On Ian DO Ones Bun dwy Candhln (g 02 mn) nI" l a" 2 - am A6 8.57 7.57

  4. Three-dimensional planning and use of patient-specific guides improve glenoid component position: an in vitro study.

    PubMed

    Walch, Gilles; Vezeridis, Peter S; Boileau, Pascal; Deransart, Pierric; Chaoui, Jean

    2015-02-01

    Glenoid component positioning is a key factor for success in total shoulder arthroplasty. Three-dimensional (3D) measurements of glenoid retroversion, inclination, and humeral head subluxation are helpful tools for preoperative planning. The purpose of this study was to assess the reliability and precision of a novel surgical method for placing the glenoid component with use of patient-specific templates created by preoperative surgical planning and 3D modeling. A preoperative computed tomography examination of cadaveric scapulae (N = 18) was performed. The glenoid implants were virtually placed, and patient-specific guides were created to direct the guide pin into the desired orientation and position in the glenoid. The 3D orientation and position of the guide pin were evaluated by performing a postoperative computed tomography scan for each scapula. The differences between the preoperative planning and the achieved result were analyzed. The mean error in 3D orientation of the guide pin was 2.39°, the mean entry point position error was 1.05 mm, and the mean inclination angle error was 1.42°. The average error in the version angle was 1.64°. There were no technical difficulties or complications related to use of patient-specific guides for guide pin placement. Quantitative analysis of guide pin positioning demonstrated a good correlation between preoperative planning and the achieved position of the guide pin. This study demonstrates the reliability and precision of preoperative planning software and patient-specific guides for glenoid component placement in total shoulder arthroplasty. Copyright © 2015. Published by Elsevier Inc.

  5. Follow-up of negative MRI-targeted prostate biopsies: when are we missing cancer?

    PubMed

    Gold, Samuel A; Hale, Graham R; Bloom, Jonathan B; Smith, Clayton P; Rayn, Kareem N; Valera, Vladimir; Wood, Bradford J; Choyke, Peter L; Turkbey, Baris; Pinto, Peter A

    2018-05-21

    Multiparametric magnetic resonance imaging (mpMRI) has improved clinicians' ability to detect clinically significant prostate cancer (csPCa). Combining or fusing these images with the real-time imaging of transrectal ultrasound (TRUS) allows urologists to better sample lesions with a targeted biopsy (Tbx) leading to the detection of greater rates of csPCa and decreased rates of low-risk PCa. In this review, we evaluate the technical aspects of the mpMRI-guided Tbx procedure to identify possible sources of error and provide clinical context to a negative Tbx. A literature search was conducted of possible reasons for false-negative TBx. This includes discussion on false-positive mpMRI findings, termed "PCa mimics," that may incorrectly suggest high likelihood of csPCa as well as errors during Tbx resulting in inexact image fusion or biopsy needle placement. Despite the strong negative predictive value associated with Tbx, concerns of missed disease often remain, especially with MR-visible lesions. This raises questions about what to do next after a negative Tbx result. Potential sources of error can arise from each step in the targeted biopsy process ranging from "PCa mimics" or technical errors during mpMRI acquisition to failure to properly register MRI and TRUS images on a fusion biopsy platform to technical or anatomic limits on needle placement accuracy. A better understanding of these potential pitfalls in the mpMRI-guided Tbx procedure will aid interpretation of a negative Tbx, identify areas for improving technical proficiency, and improve both physician understanding of negative Tbx and patient-management options.

  6. Particle contamination effects in EUVL: enhanced theory for the analytical determination of critical particle sizes

    NASA Astrophysics Data System (ADS)

    Brandstetter, Gerd; Govindjee, Sanjay

    2012-03-01

    Existing analytical and numerical methodologies are discussed and then extended in order to calculate critical contamination-particle sizes, which will result in deleterious effects during EUVL E-chucking in the face of an error budget on the image-placement-error (IPE). The enhanced analytical models include a gap dependant clamping pressure formulation, the consideration of a general material law for realistic particle crushing and the influence of frictional contact. We present a discussion of the defects of the classical de-coupled modeling approach where particle crushing and mask/chuck indentation are separated from the global computation of mask bending. To repair this defect we present a new analytic approach based on an exact Hankel transform method which allows a fully coupled solution. This will capture the contribution of the mask indentation to the image-placement-error (estimated IPE increase of 20%). A fully coupled finite element model is used to validate the analytical models and to further investigate the impact of a mask back-side CrN-layer. The models are applied to existing experimental data with good agreement. For a standard material combination, a given IPE tolerance of 1 nm and a 15 kPa closing pressure, we derive bounds for single particles of cylindrical shape (radius × height < 44 μm) and spherical shape (diameter < 12 μm).

  7. Evaluation of photomask flatness compensation for extreme ultraviolet lithography

    NASA Astrophysics Data System (ADS)

    Ballman, Katherine; Lee, Christopher; Zimmerman, John; Dunn, Thomas; Bean, Alexander

    2016-10-01

    As the semiconductor industry continues to strive towards high volume manufacturing for EUV, flatness specifications for photomasks have decreased to below 10nm for 2018 production, however the current champion masks being produced report P-V flatness values of roughly 50nm. Write compensation presents the promising opportunity to mitigate pattern placement errors through the use of geometrically adjusted target patterns which counteract the reticle's flatness induced distortions and address the differences in chucking mechanisms between e-beam write and electrostatic clamping during scan. Compensation relies on high accuracy flatness data which provides the critical topographical components of the reticle to the write tool. Any errors included in the flatness data file are translated to the pattern during the write process, which has now driven flatness measurement tools to target a 6σ reproducibility <1nm. Using data collected from a 2011 Sematech study on the Alpha Demo Tool, the proposed methodology for write compensation is validated against printed wafer results. Topographic features which lack compensation capability must then be held to stringent specifications in order to limit their contributions to the final image placement error (IPE) at wafer. By understanding the capabilities and limitations of write compensation, it is then possible to shift flatness requirements towards the "non-correctable" portion of the reticle's profile, potentially relieving polishers from having to adhere to the current single digit flatness specifications.

  8. Prediction and realization of ITER-like pedestal pressure in the high- B tokamak Alcator C-Mod

    NASA Astrophysics Data System (ADS)

    Hughes, Jerry

    2017-10-01

    Fusion power in a burning plasma will scale as the square of the plasma pressure, which is increased in a straightforward way by increasing magnetic field: Pfus p2 B4 . Experiments on Alcator C-Mod, a compact high- B tokamak, have tested predictive capability for pedestal pressure, at toroidal field BT up to 8T , and poloidal field BP up to 1T . These reactor-like fields enable C-Mod to approach an ITER predicted value of 90kPa . This is expected if, as in the EPED model, the pedestal is constrained by onset of kinetic ballooning modes (KBMs) and peeling-ballooning modes (PMB), yielding a pressure pedestal approximately as pped BT ×BP . One successful path to high confinement on C-Mod is the high-density (ne > 3 ×1020m-3) approach, pursued using enhanced D-alpha (EDAs) H-mode. In EDA H-mode, transport regulates both the pedestal profiles and the core impurity content, holding the pedestal stationary, at just below the PBM stability boundary. We have extended this stationary ELM-suppressed regime to the highest magnetic fields achievable on C-Mod, and used it to approach the maximum pedestal predicted by EPED at high density: pped 60kPa . Another approach to high pressure utilizes a pedestal limited by PBMs at low collisionality, where pressure increases with density and EPED predicts access to a higher ``Super H'' solution for pped. Experiments at reduced density (ne < 2 ×1020m-3) and strong plasma shaping (δ > 0.5) accessed these regimes on C-Mod, producing pedestals with world record pped 80kPa , at Tped 2keV . In both the high and low density approaches, the impact of the pedestal on core performance is substantial. Our exploration of high pedestal regimes yielded a volume-averaged pressure 〈 p 〉 > 2atm , a world record value for a magnetic fusion device. The results hold promise for the projection of pedestal pressure and overall performance of high field burning plasma devices. Supported by U.S. Department of Energy awards DE-FC02-99ER54512, DE-FG02-95ER54309, DE-FC02-06ER54873, DE-AC02-09CH11466, DE-SC0007880 using Alcator C-Mod, a DOE Office of Science User Facility.

  9. High-Fidelity Simulation: A New Method for Improving Medication Administration Skills of Undergraduate Nursing Students in Jordan

    ERIC Educational Resources Information Center

    Mohammad, Anas Ahmad Ali

    2017-01-01

    Although administering medicines is one of the core nursing actions, errors surrounding this task are prevalent amongst nurses and nursing students. Continued dependence on traditional teaching methods and greater demand and competition for clinical placements are some barriers to expanding medication administration practices for nursing students.…

  10. Electrophoretic build-up of multi nanoparticle array for a highly sensitive immunoassay

    PubMed Central

    Han, Jin-Hee; Kim, Hee-Joo; Sudheendra, L.; Hass, Elizabeth A.; Gee, Shirley J.; Hammock, Bruce D.; Kennedy, Ian M.

    2012-01-01

    One of the challenges in shrinking immunoassays to smaller sizes is to immobilize the biological molecules to nanometer-scaled spots. To overcome this complication, we have employed a particle-based immunoassay to create a nanostructured platform with a regular array of sensing elements. The technique makes use of an electrophoretic particle entrapment system (EPES) to immobilize nanoparticles that are coated with biological reagents into wells using a very small trapping potential. To provide useful information for controlling the trapping force and optimal design of the nanoarray, electrophoretic trapping of a nanoparticle was modeled numerically. The trapping efficiency, defined as the fraction of wells occupied by a single particle, was 91%. The performance of the array was demonstrated with a competitive immunoassay for a small molecule analyte, 3-phenoxybenzoic acid (214.2 g mole−1). The limit of detection determined with a basic fluorescence microscope was 0.006 μg l−1 (30 pM); this represented a sixteen-fold improvement in sensitivity compared to a standard 96-well plate-based ELISA; the improvement was attributed to the small size of the sample volume and the presence of light diffraction among factors unique to this structure. The EPES/nanoarray system promises to offer a new standard in applications that require portable, point-of-care and real-time monitoring with high sensitivity. PMID:23021853

  11. Incidental Prostate Adenocarcinoma in Cystoprostatectomy Specimens: Partial Versus Complete Prostate Sampling.

    PubMed

    Filter, Emily R; Gabril, Manal Y; Gomez, Jose A; Wang, Peter Z T; Chin, Joseph L; Izawa, Jonathan; Moussa, Madeleine

    2017-08-01

    The rate of incidental prostate adenocarcinoma (PCa) detection in radical cystoprostatectomy (RCP) varies widely, ranging from 15% to 54%. Such variability may be explained by institutional differences in prostate grossing protocols. Either partial or complete submission of the prostate gland in RCP may result in detection of clinically insignificant or significant incidental PCa. The aim of the study was to compare the clinical significance of PCa in RCP specimens in partial versus complete sampling. Seventy-two out of 158 RCP cases showed incidental PCa. The pathologic features, including Gleason score, margin status, extraprostatic extension (EPE), seminal vesicle invasion (SVI), PCa stage, and tumor volume, were assessed. The 72 cases were divided into partial (n = 21, 29.1%) and complete sampling (n = 51, 70.8%) groups. EPE was detected in 13/72 (18.1%) with 11/13 (84.6%) cases in the complete group. Positive margins were present in 11/72 (15.3%) with 9/11 (81.8%) in the complete group. SVI was detected in 4/72 (5.6%) with 3/4 (75.0%) in the complete group. Overall, 4/72 (5.6%) had a Gleason score >7, all of which were in the complete group. Our data suggest that complete sampling of the prostate may be the ideal approach to grossing RCP specimens, allowing for greater detection of clinically significant incidental PCa.

  12. Determinants of climate change adaptation strategies used by fish farmers in Epe Local Government Area of Lagos State, Nigeria.

    PubMed

    Arimi, Kayode S

    2014-05-01

    Undesirable impacts of climate change have been a common occurrence that has made fish farmers in developing countries adopt some climate-change adaptation strategies. However, little is known about determinants of climate-change adaptation strategies used by these fish farmers. This study, therefore, articulates novelties on adaptation to climate change, as well ascertains determinants of adaptation strategies used by fish farmers in Epe, Lagos State, Nigeria. Climate change adaptation strategies mostly used by fish farmers include frequent seeking for early warning information about climate change (76.7%) and avoidance of areas susceptible to flooding (60.0%). Climate-change adaptation strategies used by fish farmers were significantly influenced by access to early warning information (β = 7.21), knowledge of farmers about climate change adaptation strategies (β = 8.86), access to capital (β = 28.25), and participation in workshop and conferences (β = 37.19) but were reduced by number of fish stocking (β = -2.06). The adaptation strategies used by fish farmers were autonomous and mostly determined by the access to credit facilities and information. Development policy should focus on carbon capture and storage technology in order to reduce adverse impacts of climate change, as well as making early warning information on climate change available to fish farmers. These will enhance adaptation to climate change. © 2013 Society of Chemical Industry.

  13. Extension of sonic anemometry to high subsonic Mach number flows

    NASA Astrophysics Data System (ADS)

    Otero, R.; Lowe, K. T.; Ng, W. F.

    2017-03-01

    In the literature, the application of sonic anemometry has been limited to low subsonic Mach number, near-incompressible flow conditions. To the best of the authors’ knowledge, this paper represents the first time a sonic anemometry approach has been used to characterize flow velocity beyond Mach 0.3. Using a high speed jet, flow velocity was measured using a modified sonic anemometry technique in flow conditions up to Mach 0.83. A numerical study was conducted to identify the effects of microphone placement on the accuracy of the measured velocity. Based on estimated error strictly due to uncertainty in time-of-acoustic flight, a random error of +/- 4 m s-1 was identified for the configuration used in this experiment. Comparison with measurements from a Pitot probe indicated a velocity RMS error of +/- 9 m s-1. The discrepancy in error is attributed to a systematic error which may be calibrated out in future work. Overall, the experimental results from this preliminary study support the use of acoustics for high subsonic flow characterization.

  14. Characterization of the International Linear Collider damping ring optics

    NASA Astrophysics Data System (ADS)

    Shanks, J.; Rubin, D. L.; Sagan, D.

    2014-10-01

    A method is presented for characterizing the emittance dilution and dynamic aperture for an arbitrary closed lattice that includes guide field magnet errors, multipole errors and misalignments. This method, developed and tested at the Cornell Electron Storage Ring Test Accelerator (CesrTA), has been applied to the damping ring lattice for the International Linear Collider (ILC). The effectiveness of beam based emittance tuning is limited by beam position monitor (BPM) measurement errors, number of corrector magnets and their placement, and correction algorithm. The specifications for damping ring magnet alignment, multipole errors, number of BPMs, and precision in BPM measurements are shown to be consistent with the required emittances and dynamic aperture. The methodology is then used to determine the minimum number of position monitors that is required to achieve the emittance targets, and how that minimum depends on the location of the BPMs. Similarly, the maximum tolerable multipole errors are evaluated. Finally, the robustness of each BPM configuration with respect to random failures is explored.

  15. Visual, Physiological, and Aesthetic Factors and Pitfalls in Asian Blepharoplasty

    PubMed Central

    Chen, William Pai-Dei

    2016-01-01

    Double eyelid surgery to create an upper-lid crease in Asian patients is one of the more popular aesthetic surgeries among people of Asian descent. Much has been written about the myriad methods, but little has been written about the underlying factors that predispose a patient to complications and suboptimal results. This article touches on some of the possible errors in placement of crease height in upper blepharoplasty and the pitfalls that can be associated with permanent placement of nondissolvable sutures that encircle the complex layers of the upper eyelid, as well as the ideal eyelid crease wound closure and its biodynamics. One should consider these factors in any form of upper eyelid procedure, as they are not merely applicable to upper blepharoplasty. PMID:26673576

  16. Gait parameter and event estimation using smartphones.

    PubMed

    Pepa, Lucia; Verdini, Federica; Spalazzi, Luca

    2017-09-01

    The use of smartphones can greatly help for gait parameters estimation during daily living, but its accuracy needs a deeper evaluation against a gold standard. The objective of the paper is a step-by-step assessment of smartphone performance in heel strike, step count, step period, and step length estimation. The influence of smartphone placement and orientation on estimation performance is evaluated as well. This work relies on a smartphone app developed to acquire, process, and store inertial sensor data and rotation matrices about device position. Smartphone alignment was evaluated by expressing the acceleration vector in three reference frames. Two smartphone placements were tested. Three methods for heel strike detection were considered. On the basis of estimated heel strikes, step count is performed, step period is obtained, and the inverted pendulum model is applied for step length estimation. Pearson correlation coefficient, absolute and relative errors, ANOVA, and Bland-Altman limits of agreement were used to compare smartphone estimation with stereophotogrammetry on eleven healthy subjects. High correlations were found between smartphone and stereophotogrammetric measures: up to 0.93 for step count, to 0.99 for heel strike, 0.96 for step period, and 0.92 for step length. Error ranges are comparable to those in the literature. Smartphone placement did not affect the performance. The major influence of acceleration reference frames and heel strike detection method was found in step count. This study provides detailed information about expected accuracy when smartphone is used as a gait monitoring tool. The obtained results encourage real life applications. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. EM-navigated catheter placement for gynecologic brachytherapy: an accuracy study

    NASA Astrophysics Data System (ADS)

    Mehrtash, Alireza; Damato, Antonio; Pernelle, Guillaume; Barber, Lauren; Farhat, Nabgha; Viswanathan, Akila; Cormack, Robert; Kapur, Tina

    2014-03-01

    Gynecologic malignancies, including cervical, endometrial, ovarian, vaginal and vulvar cancers, cause significant mortality in women worldwide. The standard care for many primary and recurrent gynecologic cancers consists of chemoradiation followed by brachytherapy. In high dose rate (HDR) brachytherapy, intracavitary applicators and /or interstitial needles are placed directly inside the cancerous tissue so as to provide catheters to deliver high doses of radiation. Although technology for the navigation of catheters and needles is well developed for procedures such as prostate biopsy, brain biopsy, and cardiac ablation, it is notably lacking for gynecologic HDR brachytherapy. Using a benchtop study that closely mimics the clinical interstitial gynecologic brachytherapy procedure, we developed a method for evaluating the accuracy of image-guided catheter placement. Future bedside translation of this technology offers the potential benefit of maximizing tumor coverage during catheter placement while avoiding damage to the adjacent organs, for example bladder, rectum and bowel. In the study, two independent experiments were performed on a phantom model to evaluate the targeting accuracy of an electromagnetic (EM) tracking system. The procedure was carried out using a laptop computer (2.1GHz Intel Core i7 computer, 8GB RAM, Windows 7 64-bit), an EM Aurora tracking system with a 1.3mm diameter 6 DOF sensor, and 6F (2 mm) brachytherapy catheters inserted through a Syed-Neblett applicator. The 3D Slicer and PLUS open source software were used to develop the system. The mean of the targeting error was less than 2.9mm, which is comparable to the targeting errors in commercial clinical navigation systems.

  18. Fixing Stellarator Magnetic Surfaces

    NASA Astrophysics Data System (ADS)

    Hanson, James D.

    1999-11-01

    Magnetic surfaces are a perennial issue for stellarators. The design heuristic of finding a magnetic field with zero perpendicular component on a specified outer surface often yields inner magnetic surfaces with very small resonant islands. However, magnetic fields in the laboratory are not design fields. Island-causing errors can arise from coil placement errors, stray external fields, and design inadequacies such as ignoring coil leads and incomplete characterization of current distributions within the coil pack. The problem addressed is how to eliminate such error-caused islands. I take a perturbation approach, where the zero order field is assumed to have good magnetic surfaces, and comes from a VMEC equilibrium. The perturbation field consists of error and correction pieces. The error correction method is to determine the correction field so that the sum of the error and correction fields gives zero island size at specified rational surfaces. It is particularly important to correctly calculate the island size for a given perturbation field. The method works well with many correction knobs, and a Singular Value Decomposition (SVD) technique is used to determine minimal corrections necessary to eliminate islands.

  19. Investigation of Brittle Fractures in Graphite-Epoxy Composites Subjected to Impact

    DTIC Science & Technology

    1975-05-01

    Dspertlmew of the Army position unless so des •i•ated by othr authrized documents. Men Goverment drawings. epeOsftions. or other data we used for any...FRACTURE CHARACTERISTICS OF SOME FIBER-STRENGTHEN,1ED EPOXY RESIN SYSTEMS, E. 1. duPont de Nemours and Company, Incorporated, Wilmington, Delaware...Corporation Report TR-0172(SZ816-15)- 1, December 1971. 35 a LAYERS WITH Ela DIFFERENIT C (EACH LAYER ISOTROPIC) E la E lb t Elc E’ In Vila V lb ý VIC

  20. Validation of elastic registration algorithms based on adaptive irregular grids for medical applications

    NASA Astrophysics Data System (ADS)

    Franz, Astrid; Carlsen, Ingwer C.; Renisch, Steffen; Wischmann, Hans-Aloys

    2006-03-01

    Elastic registration of medical images is an active field of current research. Registration algorithms have to be validated in order to show that they fulfill the requirements of a particular clinical application. Furthermore, validation strategies compare the performance of different registration algorithms and can hence judge which algorithm is best suited for a target application. In the literature, validation strategies for rigid registration algorithms have been analyzed. For a known ground truth they assess the displacement error at a few landmarks, which is not sufficient for elastic transformations described by a huge number of parameters. Hence we consider the displacement error averaged over all pixels in the whole image or in a region-of-interest of clinical relevance. Using artificially, but realistically deformed images of the application domain, we use this quality measure to analyze an elastic registration based on transformations defined on adaptive irregular grids for the following clinical applications: Magnetic Resonance (MR) images of freely moving joints for orthopedic investigations, thoracic Computed Tomography (CT) images for the detection of pulmonary embolisms, and transmission images as used for the attenuation correction and registration of independently acquired Positron Emission Tomography (PET) and CT images. The definition of a region-of-interest allows to restrict the analysis of the registration accuracy to clinically relevant image areas. The behaviour of the displacement error as a function of the number of transformation control points and their placement can be used for identifying the best strategy for the initial placement of the control points.

  1. In vivo reproducibility of robotic probe placement for a novel ultrasound-guided radiation therapy system

    PubMed Central

    Lediju Bell, Muyinatu A.; Sen, H. Tutkun; Iordachita, Iulian; Kazanzides, Peter; Wong, John

    2014-01-01

    Abstract. Ultrasound can provide real-time image guidance of radiation therapy, but the probe-induced tissue deformations cause local deviations from the treatment plan. If placed during treatment planning, the probe causes streak artifacts in required computed tomography (CT) images. To overcome these challenges, we propose robot-assisted placement of an ultrasound probe, followed by replacement with a geometrically identical, CT-compatible model probe. In vivo reproducibility was investigated by implanting a canine prostate, liver, and pancreas with three 2.38-mm spherical markers in each organ. The real probe was placed to visualize the markers and subsequently replaced with the model probe. Each probe was automatically removed and returned to the same position or force. Under position control, the median three-dimensional reproducibility of marker positions was 0.6 to 0.7 mm, 0.3 to 0.6 mm, and 1.1 to 1.6 mm in the prostate, liver, and pancreas, respectively. Reproducibility was worse under force control. Probe substitution errors were smallest for the prostate (0.2 to 0.6 mm) and larger for the liver and pancreas (4.1 to 6.3 mm), where force control generally produced larger errors than position control. Results indicate that position control is better than force control for this application, and the robotic approach has potential, particularly for relatively constrained organs and reproducibility errors that are smaller than established treatment margins. PMID:26158038

  2. CT, MR, and ultrasound image artifacts from prostate brachytherapy seed implants: The impact of seed size

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Robertson, Andrew K. H.; Basran, Parminder S.; Thomas, Steven D.

    Purpose: To investigate the effects of brachytherapy seed size on the quality of x-ray computed tomography (CT), ultrasound (US), and magnetic resonance (MR) images and seed localization through comparison of the 6711 and 9011 {sup 125}I sources. Methods: For CT images, an acrylic phantom mimicking a clinical implantation plan and embedded with low contrast regions of interest (ROIs) was designed for both the 0.774 mm diameter 6711 (standard) and the 0.508 mm diameter 9011 (thin) seed models (Oncura, Inc., and GE Healthcare, Arlington Heights, IL). Image quality metrics were assessed using the standard deviation of ROIs between the seeds andmore » the contrast to noise ratio (CNR) within the low contrast ROIs. For US images, water phantoms with both single and multiseed arrangements were constructed for both seed sizes. For MR images, both seeds were implanted into a porcine gel and imaged with pelvic imaging protocols. The standard deviation of ROIs and CNR values were used as metrics of artifact quantification. Seed localization within the CT images was assessed using the automated seed finder in a commercial brachytherapy treatment planning system. The number of erroneous seed placements and the average and maximum error in seed placements were recorded as metrics of the localization accuracy. Results: With the thin seeds, CT image noise was reduced from 48.5 {+-} 0.2 to 32.0 {+-} 0.2 HU and CNR improved by a median value of 74% when compared with the standard seeds. Ultrasound image noise was measured at 50.3 {+-} 17.1 dB for the thin seed images and 50.0 {+-} 19.8 dB for the standard seed images, and artifacts directly behind the seeds were smaller and less prominent with the thin seed model. For MR images, CNR of the standard seeds reduced on average 17% when using the thin seeds for all different imaging sequences and seed orientations, but these differences are not appreciable. Automated seed localization required an average ({+-}SD) of 7.0 {+-} 3.5 manual corrections in seed positions for the thin seed scans and 3.0 {+-} 1.2 manual corrections in seed positions for the standard seed scans. The average error in seed placement was 1.2 mm for both seed types and the maximum error in seed placement was 2.1 mm for the thin seed scans and 1.8 mm for the standard seed scans. Conclusions: The 9011 thin seeds yielded significantly improved image quality for CT and US images but no significant differences in MR image quality.« less

  3. Comments on stellar boundary cooling and the reality of supermetallicity

    NASA Technical Reports Server (NTRS)

    Deming, D.

    1980-01-01

    The paper discusses the 'super-metal-rich' (SMR) stars and reexamines Peterson's analysis of the SMR prototype mu Leo (1978) with regard to a postulated error in continuum error. Model atmospheres are used to compute theoretical equivalent widths and to explore the sensitivity of these widths to metallicity, temperature, surface gravity, and microturbulence. It is shown that Peterson's results are sensitive to continuum placement, and that her data does not indicate that the temperature gradient is steeper in mu Leo than in normal giants. It is concluded that the SMR stars are very metal rich and are also somewhat boundary cooled, possibly due to high metallicity.

  4. EUV via hole pattern fidelity enhancement through novel resist and post-litho plasma treatment

    NASA Astrophysics Data System (ADS)

    Yaegashi, Hidetami; Koike, Kyohei; Fonseca, Carlos; Yamashita, Fumiko; Kaushik, Kumar; Morikita, Shinya; Ito, Kiyohito; Yoshimura, Shota; Timoshkov, Vadim; Maslow, Mark; Jee, Tae Kwon; Reijnen, Liesbeth; Choi, Peter; Feng, Mu; Spence, Chris; Schoofs, Stijn

    2018-03-01

    Extreme UV(EUV) technology must be potential solution for sustainable scaling, and its adoption in high volume manufacturing(HVM) is getting realistic more and more. This technology has a wide capability to mitigate various technical problem in Multi-patterning (LELELE) for via hole patterning with 193-i. It induced local pattern fidelity error such like CDU, CER, Pattern placement error. Exactly, EUV must be desirable scaling-driving tool, however, specific technical issue, named RLS (Resolution-LER-Sensitivity) triangle, obvious remaining issue. In this work, we examined hole patterning sensitizing (Lower dose approach) utilizing hole patterning restoration technique named "CD-Healing" as post-Litho. treatment.

  5. Convergence of fractional adaptive systems using gradient approach.

    PubMed

    Gallegos, Javier A; Duarte-Mermoud, Manuel A

    2017-07-01

    Conditions for boundedness and convergence of the output error and the parameter error for various Caputo's fractional order adaptive schemes based on the steepest descent method are derived in this paper. To this aim, the concept of sufficiently exciting signals is introduced, characterized and related to the concept of persistently exciting signals used in the integer order case. An application is designed in adaptive indirect control of integer order systems using fractional equations to adjust parameters. This application is illustrated for a pole placement adaptive problem. Advantages of using fractional adjustment in control adaptive schemes are experimentally obtained. Copyright © 2017 ISA. Published by Elsevier Ltd. All rights reserved.

  6. A marker placement laser device for improving repeatability in 3D-foot motion analysis.

    PubMed

    Kalkum, Eva; van Drongelen, Stefan; Mussler, Johannes; Wolf, Sebastian I; Kuni, Benita

    2016-02-01

    In 3D gait analysis, the repeated positioning of markers is associated with a high error rate, particularly when using a complex foot model with many markers. Therefore, a marker placement laser device was developed that ensures a reliable repositioning of markers. We report the development and reliability of this device for the foot at different tape conditions. In 38 subjects, markers were placed at the foot according to the Heidelberg foot measurement method. Subjects were tested barefoot and barefoot with three different tape conditions. For all conditions, a static standing trial was captured. We analyzed differences in distances between markers and the intra-class correlation coefficients (ICC). Small differences between the conditions (0.03-3.28 mm) and excellent ICCs (0.91-0.97 mm) were found for all parameters. The laser marker placement device appeared to be a reliable method to place markers on a tape at previously palpated positions and ensures an exact position. The device could find a wide application in different clinical research fields. Copyright © 2015 Elsevier B.V. All rights reserved.

  7. Exploring EUV and SAQP pattering schemes at 5nm technology node

    NASA Astrophysics Data System (ADS)

    Hamed Fatehy, Ahmed; Kotb, Rehab; Lafferty, Neal; Jiang, Fan; Word, James

    2018-03-01

    For years, Moore's law keeps driving the semiconductors industry towards smaller dimensions and higher density chips with more devices. Earlier, the correlation between exposure source's wave length and the smallest resolvable dimension, mandated the usage of Deep Ultra-Violent (DUV) optical lithography system which has been used for decades to sustain Moore's law, especially when immersion lithography was introduced with 193nm ArF laser sources. As dimensions of devices get smaller beyond Deep Ultra-Violent (DUV) optical resolution limits, the need for Extremely Ultra-Violent (EUV) optical lithography systems was a must. However, EUV systems were still under development at that time for the mass-production in semiconductors industry. Theretofore, Multi-Patterning (MP) technologies was introduced to swirl about DUV optical lithography limitations in advanced nodes beyond minimum dimension (CD) of 20nm. MP can be classified into two main categories; the first one is to split the target itself across multiple masks that give the original target patterns when they are printed. This category includes Double, Triple and Quadruple patterning (DP, TP, and QP). The second category is the Self-Aligned Patterning (SAP) where the target is divided into Mandrel patterns and non-Mandrel patterns. The Mandrel patterns get printed first, then a self-aligned sidewalls are grown around these printed patterns drawing the other non-Mandrel targets, afterword, a cut mask(s) is used to define target's line-ends. This approach contains Self-Aligned-Double Pattering (SADP) and Self-Aligned- Quadruple-Pattering (SAQP). DUV and MP along together paved the way for the industry down to 7nm. However, with the start of development at the 5nm node and the readiness of EUV, the differentiation question is aroused again, which pattering approach should be selected, direct printing using EUV or DUV with MP, or a hybrid flow that contains both DUV-MP and EUV. In this work we are comparing two potential pattering techniques for Back End Of Line (BEOL) metal layers in the 5nm technology node, the first technique is Single Exposure EUV (SE-EUV) with a Direct Patterning EUV lithography process, and the second one is Self-Aligned Quadruple Patterning (SAQP) with a hybrid lithography processes, where the drawn metal target layer is decomposed into a Mandrel mask and Blocks/Cut mask, Mandrel mask is printed using DUV 193i lithography process, while Block/Cut Mask is printed using SE-EUV lithography process. The pros and cons of each technique are quantified based on Edge-Placement-Error (EPE) and Process Variation Band (PVBand) measured at 1D and 2D edges. The layout used in this comparison is a candidate layout for Foundries 5nm process node.

  8. Incidence, recurrence and cost of hyperglycaemic crises requiring emergency treatment in Andalusia, Spain.

    PubMed

    Barranco, R J; Gomez-Peralta, F; Abreu, C; Delgado-Rodriguez, M; Moreno-Carazo, A; Romero, F; de la Cal, M A; Barranco, J M; Pasquel, F J; Umpierrez, G E

    2017-07-01

    Hyperglycaemic crises (diabetic ketoacidosis and hyperosmolar hyperglycaemic state) are medical emergencies in people with diabetes. We aimed to determine their incidence, recurrence and economic impact. An observational study of hyperglycaemic crises cases using the database maintained by the out-of-hospital emergency service, the Healthcare Emergency Public Service (EPES) during 2012. The EPES provides emergency medical services to the total population of Andalusia, Spain (8.5 million inhabitants) and records data on the incidence, resource utilization and cost of out-of-hospital medical care. Direct costs were estimated using public prices for health services updated to 2012. Among 1 137 738 emergency calls requesting medical assistance, 3157 were diagnosed with hyperglycaemic crises by an emergency coordinator, representing 2.9 cases per 1000 persons with diabetes [95% confidence intervals (CI) 2.8 to 3.0]. The incidence of diabetic ketoacidosis was 2.5 cases per 1000 persons with diabetes (95% CI 2.4 to 2.6) and the incidence of hyperosmolar hyperglycaemic state was 0.4 cases per 1000 persons with diabetes (95% CI 0.4 to 0.5). In total, 17.7% (n = 440) of people had one or more hyperglycaemic crisis. The estimated total direct cost was €4 662 151, with a mean direct cost per episode of €1476.8 ± 217.8. Hyperglycaemic crises require high resource utilization of emergency medical services and have a significant economic impact on the health system. © 2017 Diabetes UK.

  9. Lessons learned: wrong intraocular lens.

    PubMed

    Schein, Oliver D; Banta, James T; Chen, Teresa C; Pritzker, Scott; Schachat, Andrew P

    2012-10-01

    To report cases involving the placement of the wrong intraocular lens (IOL) at the time of cataract surgery where human error occurred. Retrospective small case series, convenience sample. Seven surgical cases. Institutional review of errors committed and subsequent improvements to clinical protocols. Lessons learned and changes in procedures adapted. The pathways to a wrong IOL are many but largely reflect some combination of poor surgical team communication, transcription error, lack of preoperative clarity in surgical planning or failure to match the patient, and IOL calculation sheet with 2 unique identifiers. Safety in surgery involving IOLs is enhanced both by strict procedures, such as an IOL-specific "time-out," and the fostering of a surgical team culture in which all members are encouraged to voice questions and concerns. Copyright © 2012 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  10. Lower-limb amputee ankle and hip kinetic response to an imposed error in mediolateral foot placement.

    PubMed

    Segal, Ava D; Shofer, Jane B; Klute, Glenn K

    2015-11-26

    Maintaining balance while walking is challenging for lower limb amputees. The effect of prosthetic foot stiffness on recovery kinetics from an error in foot placement may inform prescription practice and lead to new interventions designed to improve balance. Ten unilateral transtibial amputees were fit with two prosthetic feet with different stiffness properties in random order. After a 3-week acclimation period, they returned to the lab for testing before switching feet. Twelve non-amputees also participated in a single data collection. While walking on an instrumented treadmill, we imposed a repeatable, unexpected medial or lateral disturbance in foot placement by releasing a burst of air at the ankle just before heel strike. Three-dimensional motion capture, ground reaction force and center of pressure (COP) data were collected for two steps prior, the disturbed step and three steps after the disturbance. During undisturbed walking, coronal ankle impulse was lower by 42% for amputees wearing a stiff compared to a compliant foot (p=0.017); however, across steps, both prosthetic recovery patterns were similar compared to the sound limb and non-amputees. Peak coronal hip moment was 15-20% lower for both foot types during undisturbed walking (p<0.001), with less change in response to the medial disturbance (p<0.001) compared to the sound limb and non-amputees. Amputee prosthetic COP excursion was unaffected by the disturbance (2.4% change) compared to the sound limb (59% change; p<0.001) and non-amputees (55% change; p<0.001). These findings imply that a prosthetic foot-ankle system able to contribute to ankle kinetics may improve walking balance among amputees. Published by Elsevier Ltd.

  11. Aortic blood pressure measured via EIT: investigation of different measurement settings.

    PubMed

    Braun, Fabian; Proença, Martin; Rapin, Michael; Lemay, Mathieu; Adler, Andy; Grychtol, Bartłomiej; Solà, Josep; Thiran, Jean-Philippe

    2015-06-01

    Electrical impedance tomography (EIT) allows the measurement of intra-thoracic impedance changes related to cardiovascular activity. As a safe and low-cost imaging modality, EIT is an appealing candidate for non-invasive and continuous haemodynamic monitoring. EIT has recently been shown to allow the assessment of aortic blood pressure via the estimation of the aortic pulse arrival time (PAT). However, finding the aortic signal within EIT image sequences is a challenging task: the signal has a small amplitude and is difficult to locate due to the small size of the aorta and the inherent low spatial resolution of EIT. In order to most reliably detect the aortic signal, our objective was to understand the effect of EIT measurement settings (electrode belt placement, reconstruction algorithm). This paper investigates the influence of three transversal belt placements and two commonly-used difference reconstruction algorithms (Gauss-Newton and GREIT) on the measurement of aortic signals in view of aortic blood pressure estimation via EIT. A magnetic resonance imaging based three-dimensional finite element model of the haemodynamic bio-impedance properties of the human thorax was created. Two simulation experiments were performed with the aim to (1) evaluate the timing error in aortic PAT estimation and (2) quantify the strength of the aortic signal in each pixel of the EIT image sequences. Both experiments reveal better performance for images reconstructed with Gauss-Newton (with a noise figure of 0.5 or above) and a belt placement at the height of the heart or higher. According to the noise-free scenarios simulated, the uncertainty in the analysis of the aortic EIT signal is expected to induce blood pressure errors of at least ± 1.4 mmHg.

  12. Alternate methods for FAAT S-curve generation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kaufman, A.M.

    The FAAT (Foreign Asset Assessment Team) assessment methodology attempts to derive a probability of effect as a function of incident field strength. The probability of effect is the likelihood that the stress put on a system exceeds its strength. In the FAAT methodology, both the stress and strength are random variables whose statistical properties are estimated by experts. Each random variable has two components of uncertainty: systematic and random. The systematic uncertainty drives the confidence bounds in the FAAT assessment. Its variance can be reduced by improved information. The variance of the random uncertainty is not reducible. The FAAT methodologymore » uses an assessment code called ARES to generate probability of effect curves (S-curves) at various confidence levels. ARES assumes log normal distributions for all random variables. The S-curves themselves are log normal cumulants associated with the random portion of the uncertainty. The placement of the S-curves depends on confidence bounds. The systematic uncertainty in both stress and strength is usually described by a mode and an upper and lower variance. Such a description is not consistent with the log normal assumption of ARES and an unsatisfactory work around solution is used to obtain the required placement of the S-curves at each confidence level. We have looked into this situation and have found that significant errors are introduced by this work around. These errors are at least several dB-W/cm{sup 2} at all confidence levels, but they are especially bad in the estimate of the median. In this paper, we suggest two alternate solutions for the placement of S-curves. To compare these calculational methods, we have tabulated the common combinations of upper and lower variances and generated the relevant S-curves offsets from the mode difference of stress and strength.« less

  13. Robustness study of the pseudo open-loop controller for multiconjugate adaptive optics.

    PubMed

    Piatrou, Piotr; Gilles, Luc

    2005-02-20

    Robustness of the recently proposed "pseudo open-loop control" algorithm against various system errors has been investigated for the representative example of the Gemini-South 8-m telescope multiconjugate adaptive-optics system. The existing model to represent the adaptive-optics system with pseudo open-loop control has been modified to account for misalignments, noise and calibration errors in deformable mirrors, and wave-front sensors. Comparison with the conventional least-squares control model has been done. We show with the aid of both transfer-function pole-placement analysis and Monte Carlo simulations that POLC remains remarkably stable and robust against very large levels of system errors and outperforms in this respect least-squares control. Approximate stability margins as well as performance metrics such as Strehl ratios and rms wave-front residuals averaged over a 1-arc min field of view have been computed for different types and levels of system errors to quantify the expected performance degradation.

  14. PI controller design of a wind turbine: evaluation of the pole-placement method and tuning using constrained optimization

    NASA Astrophysics Data System (ADS)

    Mirzaei, Mahmood; Tibaldi, Carlo; Hansen, Morten H.

    2016-09-01

    PI/PID controllers are the most common wind turbine controllers. Normally a first tuning is obtained using methods such as pole-placement or Ziegler-Nichols and then extensive aeroelastic simulations are used to obtain the best tuning in terms of regulation of the outputs and reduction of the loads. In the traditional tuning approaches, the properties of different open loop and closed loop transfer functions of the system are not normally considered. In this paper, an assessment of the pole-placement tuning method is presented based on robustness measures. Then a constrained optimization setup is suggested to automatically tune the wind turbine controller subject to robustness constraints. The properties of the system such as the maximum sensitivity and complementary sensitivity functions (Ms and Mt ), along with some of the responses of the system, are used to investigate the controller performance and formulate the optimization problem. The cost function is the integral absolute error (IAE) of the rotational speed from a disturbance modeled as a step in wind speed. Linearized model of the DTU 10-MW reference wind turbine is obtained using HAWCStab2. Thereafter, the model is reduced with model order reduction. The trade-off curves are given to assess the tunings of the poles- placement method and a constrained optimization problem is solved to find the best tuning.

  15. Intergration of system identification and robust controller designs for flexible structures in space

    NASA Technical Reports Server (NTRS)

    Juang, Jer-Nan; Lew, Jiann-Shiun

    1990-01-01

    An approach is developed using experimental data to identify a reduced-order model and its model error for a robust controller design. There are three steps involved in the approach. First, an approximately balanced model is identified using the Eigensystem Realization Algorithm, which is an identification algorithm. Second, the model error is calculated and described in frequency domain in terms of the H(infinity) norm. Third, a pole placement technique in combination with a H(infinity) control method is applied to design a controller for the considered system. A set experimental data from an existing setup, namely the Mini-Mast system, is used to illustrate and verify the approach.

  16. In-die mask registration measurement on 28nm-node and beyond

    NASA Astrophysics Data System (ADS)

    Chen, Shen Hung; Cheng, Yung Feng; Chen, Ming Jui

    2013-09-01

    As semiconductor go to smaller node, the critical dimension (CD) of process become more and more small. For lithography, RET (Resolution Enhancement Technology) applications can be used for wafer printing of smaller CD/pitch on 28nm node and beyond. SMO (Source Mask Optimization), DPT (Double Patterning Technology) and SADP (Self-Align Double Patterning) can provide lower k1 value for lithography. In another way, image placement error and overlay control also become more and more important for smaller chip size (advanced node). Mask registration (image placement error) and mask overlay are important factors to affect wafer overlay control/performance especially for DPT or SADP. In traditional method, the designed registration marks (cross type, square type) with larger CD were put into scribe-line of mask frame for registration and overlay measurement. However, these patterns are far way from real patterns. It does not show the registration of real pattern directly and is not a convincing method. In this study, the in-die (in-chip) registration measurement is introduced. We extract the dummy patterns that are close to main pattern from post-OPC (Optical Proximity Correction) gds by our desired rule and choose the patterns that distribute over whole mask uniformly. The convergence test shows 100 points measurement has a reliable result.

  17. CTF Preprocessor User's Manual

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Avramova, Maria; Salko, Robert K.

    2016-05-26

    This document describes how a user should go about using the CTF pre- processor tool to create an input deck for modeling rod-bundle geometry in CTF. The tool was designed to generate input decks in a quick and less error-prone manner for CTF. The pre-processor is a completely independent utility, written in Fortran, that takes a reduced amount of input from the user. The information that the user must supply is basic information on bundle geometry, such as rod pitch, clad thickness, and axial location of spacer grids--the pre-processor takes this basic information and determines channel placement and connection informationmore » to be written to the input deck, which is the most time-consuming and error-prone segment of creating a deck. Creation of the model is also more intuitive, as the user can specify assembly and water-tube placement using visual maps instead of having to place them by determining channel/channel and rod/channel connections. As an example of the benefit of the pre-processor, a quarter-core model that contains 500,000 scalar-mesh cells was read into CTF from an input deck containing 200,000 lines of data. This 200,000 line input deck was produced automatically from a set of pre-processor decks that contained only 300 lines of data.« less

  18. Teleoperation System with Hybrid Pneumatic-Piezoelectric Actuation for MRI-Guided Needle Insertion with Haptic Feedback

    PubMed Central

    Shang, Weijian; Su, Hao; Li, Gang; Fischer, Gregory S.

    2014-01-01

    This paper presents a surgical master-slave tele-operation system for percutaneous interventional procedures under continuous magnetic resonance imaging (MRI) guidance. This system consists of a piezoelectrically actuated slave robot for needle placement with integrated fiber optic force sensor utilizing Fabry-Perot interferometry (FPI) sensing principle. The sensor flexure is optimized and embedded to the slave robot for measuring needle insertion force. A novel, compact opto-mechanical FPI sensor interface is integrated into an MRI robot control system. By leveraging the complementary features of pneumatic and piezoelectric actuation, a pneumatically actuated haptic master robot is also developed to render force associated with needle placement interventions to the clinician. An aluminum load cell is implemented and calibrated to close the impedance control loop of the master robot. A force-position control algorithm is developed to control the hybrid actuated system. Teleoperated needle insertion is demonstrated under live MR imaging, where the slave robot resides in the scanner bore and the user manipulates the master beside the patient outside the bore. Force and position tracking results of the master-slave robot are demonstrated to validate the tracking performance of the integrated system. It has a position tracking error of 0.318mm and sine wave force tracking error of 2.227N. PMID:25126446

  19. Teleoperation System with Hybrid Pneumatic-Piezoelectric Actuation for MRI-Guided Needle Insertion with Haptic Feedback.

    PubMed

    Shang, Weijian; Su, Hao; Li, Gang; Fischer, Gregory S

    2013-01-01

    This paper presents a surgical master-slave tele-operation system for percutaneous interventional procedures under continuous magnetic resonance imaging (MRI) guidance. This system consists of a piezoelectrically actuated slave robot for needle placement with integrated fiber optic force sensor utilizing Fabry-Perot interferometry (FPI) sensing principle. The sensor flexure is optimized and embedded to the slave robot for measuring needle insertion force. A novel, compact opto-mechanical FPI sensor interface is integrated into an MRI robot control system. By leveraging the complementary features of pneumatic and piezoelectric actuation, a pneumatically actuated haptic master robot is also developed to render force associated with needle placement interventions to the clinician. An aluminum load cell is implemented and calibrated to close the impedance control loop of the master robot. A force-position control algorithm is developed to control the hybrid actuated system. Teleoperated needle insertion is demonstrated under live MR imaging, where the slave robot resides in the scanner bore and the user manipulates the master beside the patient outside the bore. Force and position tracking results of the master-slave robot are demonstrated to validate the tracking performance of the integrated system. It has a position tracking error of 0.318mm and sine wave force tracking error of 2.227N.

  20. A method for improving the accuracy of stereotaxic procedures in monkeys using implanted fiducial markers in CT scans that also serve as anchor points in a stereotaxic frame.

    PubMed

    Risher, D W; Zhang, X; Kostarczyk, E; Gokin, A P; Honda, C N; Giesler, G J

    1997-04-25

    We developed a relatively inexpensive method for stereotaxic placement of electrodes or needles in the brains of monkeys. Steel balls were affixed to the skulls of monkeys. These balls served as fiducial markers and were also used as points at which the monkey's skull was held in a modified stereotaxic apparatus. Computed tomography (CT) was used to establish the location of an injection target with respect to the fiducial markers. A computer program related the CT coordinates to stereotaxic coordinates. These were used to direct an electrode marker toward a target in the hypothalamus. With the marker left in place, the monkey was removed from the stereotaxic frame and a second CT scan was performed. Corrections for errors in marker placement were made and retrograde tracers were injected. This procedure was found to be more accurate and reliable than conventional stereotaxic procedures. The accuracy and repeatability of the technique were also established using a phantom model of a monkey's skull. Two important advantages of this method are that animals can be repeatedly placed into the stereotaxic frame in precisely the same position and that there are many opportunities during the procedure to check for and correct errors.

  1. Experiments on robot-assisted navigated drilling and milling of bones for pedicle screw placement.

    PubMed

    Ortmaier, T; Weiss, H; Döbele, S; Schreiber, U

    2006-12-01

    This article presents experimental results for robot-assisted navigated drilling and milling for pedicle screw placement. The preliminary study was carried out in order to gain first insights into positioning accuracies and machining forces during hands-on robotic spine surgery. Additionally, the results formed the basis for the development of a new robot for surgery. A simplified anatomical model is used to derive the accuracy requirements. The experimental set-up consists of a navigation system and an impedance-controlled light-weight robot holding the surgical instrument. The navigation system is used to position the surgical instrument and to compensate for pose errors during machining. Holes are drilled in artificial bone and bovine spine. A quantitative comparison of the drill-hole diameters was achieved using a computer. The interaction forces and pose errors are discussed with respect to the chosen machining technology and control parameters. Within the technological boundaries of the experimental set-up, it is shown that the accuracy requirements can be met and that milling is superior to drilling. It is expected that robot assisted navigated surgery helps to improve the reliability of surgical procedures. Further experiments are necessary to take the whole workflow into account. Copyright 2006 John Wiley & Sons, Ltd.

  2. Stroke type differentiation using spectrally constrained multifrequency EIT: evaluation of feasibility in a realistic head model.

    PubMed

    Malone, Emma; Jehl, Markus; Arridge, Simon; Betcke, Timo; Holder, David

    2014-06-01

    We investigate the application of multifrequency electrical impedance tomography (MFEIT) to imaging the brain in stroke patients. The use of MFEIT could enable early diagnosis and thrombolysis of ischaemic stroke, and therefore improve the outcome of treatment. Recent advances in the imaging methodology suggest that the use of spectral constraints could allow for the reconstruction of a one-shot image. We performed a simulation study to investigate the feasibility of imaging stroke in a head model with realistic conductivities. We introduced increasing levels of modelling errors to test the robustness of the method to the most common sources of artefact. We considered the case of errors in the electrode placement, spectral constraints, and contact impedance. The results indicate that errors in the position and shape of the electrodes can affect image quality, although our imaging method was successful in identifying tissues with sufficiently distinct spectra.

  3. Quotation accuracy in medical journal articles-a systematic review and meta-analysis.

    PubMed

    Jergas, Hannah; Baethge, Christopher

    2015-01-01

    Background. Quotations and references are an indispensable element of scientific communication. They should support what authors claim or provide important background information for readers. Studies indicate, however, that quotations not serving their purpose-quotation errors-may be prevalent. Methods. We carried out a systematic review, meta-analysis and meta-regression of quotation errors, taking account of differences between studies in error ascertainment. Results. Out of 559 studies screened we included 28 in the main analysis, and estimated major, minor and total quotation error rates of 11,9%, 95% CI [8.4, 16.6] 11.5% [8.3, 15.7], and 25.4% [19.5, 32.4]. While heterogeneity was substantial, even the lowest estimate of total quotation errors was considerable (6.7%). Indirect references accounted for less than one sixth of all quotation problems. The findings remained robust in a number of sensitivity and subgroup analyses (including risk of bias analysis) and in meta-regression. There was no indication of publication bias. Conclusions. Readers of medical journal articles should be aware of the fact that quotation errors are common. Measures against quotation errors include spot checks by editors and reviewers, correct placement of citations in the text, and declarations by authors that they have checked cited material. Future research should elucidate if and to what degree quotation errors are detrimental to scientific progress.

  4. Perioperative antiplatelet management in patients with coronary artery stenting.

    PubMed

    Tandar, Anwar; Velagapudi, Krishna N; Wilson, Brent D; Boden, William E

    2012-04-01

    Coronary artery disease is the primary cause of mortality in men and women in the United States. Transcatheter coronary intervention is the mainstay of treatment for patients with acute coronary artery disease presentations and patients with stable disease. Although percutaneous intervention initially only included balloon angioplasty, it now typically involves the placement of intracoronary stents. To overcome the limitations of bare-metal stents, namely in-stent restenosis, stents have been developed that remove pharmaceuticals that reduce neointimal hyperplasia and in-stent restenosis. However, these pharmaceutical agents also delay stent endothelialization, posing a prolonged risk of in situ thrombosis. Placement of an intracoronary stent (eg, bare-metal or drug-eluting stent) requires dual antiplatelet therapy to prevent the potentially life-threatening complication of stent thrombosis. The optimal duration of dual antiplatelet therapy following stent placement is unknown. This article discusses the factors to be considered when deciding when dual antiplatelet therapy can be safely discontinued. Unfortunately, in the hospital setting, this decision to interrupt dual antiplatelet therapy frequently must be made shortly after stent placement because of unanticipated surgical procedures or other unforeseen complications. The decision of when dual antiplatelet therapy can be safely interrupted needs to be individualized for each patient and involves factoring in the type of stent; the location and complexity of the lesion stented; post-stent lesion characteristics; the amount of time since stent placement; and the antiplatelet regimen currently in use, along with its implication for bleeding during the proposed procedure. Having a protocol in place, such as the protocol described in this article, can help guide this decision-making process and avoid confusion and potential error.

  5. The effect of subject measurement error on joint kinematics in the conventional gait model: Insights from the open-source pyCGM tool using high performance computing methods.

    PubMed

    Schwartz, Mathew; Dixon, Philippe C

    2018-01-01

    The conventional gait model (CGM) is a widely used biomechanical model which has been validated over many years. The CGM relies on retro-reflective markers placed along anatomical landmarks, a static calibration pose, and subject measurements as inputs for joint angle calculations. While past literature has shown the possible errors caused by improper marker placement, studies on the effects of inaccurate subject measurements are lacking. Moreover, as many laboratories rely on the commercial version of the CGM, released as the Plug-in Gait (Vicon Motion Systems Ltd, Oxford, UK), integrating improvements into the CGM code is not easily accomplished. This paper introduces a Python implementation for the CGM, referred to as pyCGM, which is an open-source, easily modifiable, cross platform, and high performance computational implementation. The aims of pyCGM are to (1) reproduce joint kinematic outputs from the Vicon CGM and (2) be implemented in a parallel approach to allow integration on a high performance computer. The aims of this paper are to (1) demonstrate that pyCGM can systematically and efficiently examine the effect of subject measurements on joint angles and (2) be updated to include new calculation methods suggested in the literature. The results show that the calculated joint angles from pyCGM agree with Vicon CGM outputs, with a maximum lower body joint angle difference of less than 10-5 degrees. Through the hierarchical system, the ankle joint is the most vulnerable to subject measurement error. Leg length has the greatest effect on all joints as a percentage of measurement error. When compared to the errors previously found through inter-laboratory measurements, the impact of subject measurements is minimal, and researchers should rather focus on marker placement. Finally, we showed that code modifications can be performed to include improved hip, knee, and ankle joint centre estimations suggested in the existing literature. The pyCGM code is provided in open source format and available at https://github.com/cadop/pyCGM.

  6. Box-Counting Dimension Revisited: Presenting an Efficient Method of Minimizing Quantization Error and an Assessment of the Self-Similarity of Structural Root Systems

    PubMed Central

    Bouda, Martin; Caplan, Joshua S.; Saiers, James E.

    2016-01-01

    Fractal dimension (FD), estimated by box-counting, is a metric used to characterize plant anatomical complexity or space-filling characteristic for a variety of purposes. The vast majority of published studies fail to evaluate the assumption of statistical self-similarity, which underpins the validity of the procedure. The box-counting procedure is also subject to error arising from arbitrary grid placement, known as quantization error (QE), which is strictly positive and varies as a function of scale, making it problematic for the procedure's slope estimation step. Previous studies either ignore QE or employ inefficient brute-force grid translations to reduce it. The goals of this study were to characterize the effect of QE due to translation and rotation on FD estimates, to provide an efficient method of reducing QE, and to evaluate the assumption of statistical self-similarity of coarse root datasets typical of those used in recent trait studies. Coarse root systems of 36 shrubs were digitized in 3D and subjected to box-counts. A pattern search algorithm was used to minimize QE by optimizing grid placement and its efficiency was compared to the brute force method. The degree of statistical self-similarity was evaluated using linear regression residuals and local slope estimates. QE, due to both grid position and orientation, was a significant source of error in FD estimates, but pattern search provided an efficient means of minimizing it. Pattern search had higher initial computational cost but converged on lower error values more efficiently than the commonly employed brute force method. Our representations of coarse root system digitizations did not exhibit details over a sufficient range of scales to be considered statistically self-similar and informatively approximated as fractals, suggesting a lack of sufficient ramification of the coarse root systems for reiteration to be thought of as a dominant force in their development. FD estimates did not characterize the scaling of our digitizations well: the scaling exponent was a function of scale. Our findings serve as a caution against applying FD under the assumption of statistical self-similarity without rigorously evaluating it first. PMID:26925073

  7. The effect of subject measurement error on joint kinematics in the conventional gait model: Insights from the open-source pyCGM tool using high performance computing methods

    PubMed Central

    Dixon, Philippe C.

    2018-01-01

    The conventional gait model (CGM) is a widely used biomechanical model which has been validated over many years. The CGM relies on retro-reflective markers placed along anatomical landmarks, a static calibration pose, and subject measurements as inputs for joint angle calculations. While past literature has shown the possible errors caused by improper marker placement, studies on the effects of inaccurate subject measurements are lacking. Moreover, as many laboratories rely on the commercial version of the CGM, released as the Plug-in Gait (Vicon Motion Systems Ltd, Oxford, UK), integrating improvements into the CGM code is not easily accomplished. This paper introduces a Python implementation for the CGM, referred to as pyCGM, which is an open-source, easily modifiable, cross platform, and high performance computational implementation. The aims of pyCGM are to (1) reproduce joint kinematic outputs from the Vicon CGM and (2) be implemented in a parallel approach to allow integration on a high performance computer. The aims of this paper are to (1) demonstrate that pyCGM can systematically and efficiently examine the effect of subject measurements on joint angles and (2) be updated to include new calculation methods suggested in the literature. The results show that the calculated joint angles from pyCGM agree with Vicon CGM outputs, with a maximum lower body joint angle difference of less than 10-5 degrees. Through the hierarchical system, the ankle joint is the most vulnerable to subject measurement error. Leg length has the greatest effect on all joints as a percentage of measurement error. When compared to the errors previously found through inter-laboratory measurements, the impact of subject measurements is minimal, and researchers should rather focus on marker placement. Finally, we showed that code modifications can be performed to include improved hip, knee, and ankle joint centre estimations suggested in the existing literature. The pyCGM code is provided in open source format and available at https://github.com/cadop/pyCGM. PMID:29293565

  8. Compromised JMJD6 histone demethylase activity impacts on VHL gene repression in preeclampsia.

    PubMed

    Alahari, Sruthi; Post, Martin; Rolfo, Alessandro; Weksberg, Rosanna; Caniggia, Isabella

    2018-01-24

    The von Hippel Lindau (VHL) protein is a key executor of the cellular hypoxic response that is compromised in preeclampsia, a serious disorder complicating 5-7% of pregnancies. To date, the mechanisms controlling VHL gene expression in the human placenta remain elusive. We examined VHL epigenetic regulation in normal pregnancy and in preeclampsia, a pathology characterized by placental hypoxia. Placentae were obtained from early-onset (E-PE: n=56; <34 weeks of gestation) and late onset preeclampsia (L-PE: n=19; ≥ 34 weeks of gestation). Placentae from healthy normotensive age-matched preterm and term pregnancies (PTC: n=43; TC: n=23) were included as controls. We measured the activity of Jumonji domain containing protein 6 (JMJD6), a Fe2+ and oxygen-dependent histone demethylase, and examined its function in the epigenetic control of VHL. JMJD6 regulates VHL gene expression in the human placenta. VHL downregulation in preeclampsia is dependent on decreased JMJD6 demethylase activity due to hypoxia and reduced Fe2+ bioavailability. Chromatin immunoprecipitation assays revealed decreased association of JMJD6 and its histone targets with the VHL promoter. Findings in preeclampsia were corroborated in a murine model of pharmacological hypoxia using FG-4592. Placentae from FG-4592 treated mice exhibited reduced VHL levels, accompanied by placental morphological alterations and reduced pup weights. Notably, Fe2+ supplementation rescued JMJD6 histone demethylase activity in histone from E-PE and FG-4592-treated mice. Our study uncovers novel epigenetic regulation of VHL and its functional consequences for altered oxygen and iron homeostasis in preeclampsia. Copyright © 2018 Endocrine Society

  9. Development of ITER non-activation phase operation scenarios

    DOE PAGES

    Kim, S. H.; Poli, F. M.; Koechl, F.; ...

    2017-06-29

    Non-activation phase operations in ITER in hydrogen (H) and helium (He) will be important for commissioning of tokamak systems, such as diagnostics, heating and current drive (HCD) systems, coils and plasma control systems, and for validation of techniques necessary for establishing operations in DT. The assessment of feasible HCD schemes at various toroidal fields (2.65–5.3 T) has revealed that the previously applied assumptions need to be refined for the ITER non-activation phase H/He operations. A study of the ranges of plasma density and profile shape using the JINTRAC suite of codes has indicated that the hydrogen pellet fuelling into Hemore » plasmas should be utilized taking the optimization of IC power absorption, neutral beam shine-through density limit and H-mode access into account. The EPED1 estimation of the edge pedestal parameters has been extended to various H operation conditions, and the combined EPED1 and SOLPS estimation has provided guidance for modelling the edge pedestal in H/He operations. The availability of ITER HCD schemes, ranges of achievable plasma density and profile shape, and estimation of the edge pedestal parameters for H/He plasmas have been integrated into various time-dependent tokamak discharge simulations. In this paper, various H/He scenarios at a wide range of plasma current (7.5–15 MA) and field (2.65–5.3 T) have been developed for the ITER non-activation phase operation, and the sensitivity of the developed scenarios to the used assumptions has been investigated to provide guidance for further development.« less

  10. Development of ITER non-activation phase operation scenarios

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kim, S. H.; Poli, F. M.; Koechl, F.

    Non-activation phase operations in ITER in hydrogen (H) and helium (He) will be important for commissioning of tokamak systems, such as diagnostics, heating and current drive (HCD) systems, coils and plasma control systems, and for validation of techniques necessary for establishing operations in DT. The assessment of feasible HCD schemes at various toroidal fields (2.65–5.3 T) has revealed that the previously applied assumptions need to be refined for the ITER non-activation phase H/He operations. A study of the ranges of plasma density and profile shape using the JINTRAC suite of codes has indicated that the hydrogen pellet fuelling into Hemore » plasmas should be utilized taking the optimization of IC power absorption, neutral beam shine-through density limit and H-mode access into account. The EPED1 estimation of the edge pedestal parameters has been extended to various H operation conditions, and the combined EPED1 and SOLPS estimation has provided guidance for modelling the edge pedestal in H/He operations. The availability of ITER HCD schemes, ranges of achievable plasma density and profile shape, and estimation of the edge pedestal parameters for H/He plasmas have been integrated into various time-dependent tokamak discharge simulations. In this paper, various H/He scenarios at a wide range of plasma current (7.5–15 MA) and field (2.65–5.3 T) have been developed for the ITER non-activation phase operation, and the sensitivity of the developed scenarios to the used assumptions has been investigated to provide guidance for further development.« less

  11. Effect of ambient light and age-related macular degeneration on precision walking.

    PubMed

    Alexander, M Scott; Lajoie, Kim; Neima, David R; Strath, Robert A; Robinovitch, Stephen N; Marigold, Daniel S

    2014-08-01

    To determine how age-related macular degeneration (AMD) and changes in ambient light affect the control of foot placement while walking. Ten older adults with AMD and 11 normal-sighted controls performed a precision walking task under normal (∼600 lx), dim (∼0.7 lx), and after a sudden reduction (∼600 to 0.7 lx) of light. The precision walking task involved subjects walking and stepping to the center of a series of irregularly spaced, low-contrast targets. Habitual visual acuity and contrast sensitivity and visual field function were also assessed. There were no differences between groups when performing the walking task in normal light (p > 0.05). In reduced lighting, older adults with AMD were less accurate and more variable when stepping across the targets compared to controls (p < 0.05). A sudden reduction of light proved the most challenging for this population. In the AMD group, contrast sensitivity and visual acuity were not significantly correlated with walking performance. Visual field thresholds in the AMD group were only associated with greater foot placement error and variability in the dim light walking condition (r = -0.69 to -0.87, p < 0.05). While walking performance is similar between groups in normal light, poor ambient lighting results in decreased foot placement accuracy in older adults with AMD. Improper foot placement while walking can lead to a fall and possible injury. Thus, to improve the mobility of those with AMD, strategies to enhance the environment in reduced lighting situations are necessary.

  12. Study on the calibration and optimization of double theodolites baseline

    NASA Astrophysics Data System (ADS)

    Ma, Jing-yi; Ni, Jin-ping; Wu, Zhi-chao

    2018-01-01

    For the double theodolites measurement system baseline as the benchmark of the scale of the measurement system and affect the accuracy of the system, this paper puts forward a method for calibration and optimization of the double theodolites baseline. Using double theodolites to measure the known length of the reference ruler, and then reverse the baseline formula. Based on the error propagation law, the analyses show that the baseline error function is an important index to measure the accuracy of the system, and the reference ruler position, posture and so on have an impact on the baseline error. The optimization model is established and the baseline error function is used as the objective function, and optimizes the position and posture of the reference ruler. The simulation results show that the height of the reference ruler has no effect on the baseline error; the posture is not uniform; when the reference ruler is placed at x=500mm and y=1000mm in the measurement space, the baseline error is the smallest. The experimental results show that the experimental results are consistent with the theoretical analyses in the measurement space. In this paper, based on the study of the placement of the reference ruler, for improving the accuracy of the double theodolites measurement system has a reference value.

  13. Evaluation of Two Crew Module Boilerplate Tests Using Newly Developed Calibration Metrics

    NASA Technical Reports Server (NTRS)

    Horta, Lucas G.; Reaves, Mercedes C.

    2012-01-01

    The paper discusses a application of multi-dimensional calibration metrics to evaluate pressure data from water drop tests of the Max Launch Abort System (MLAS) crew module boilerplate. Specifically, three metrics are discussed: 1) a metric to assess the probability of enveloping the measured data with the model, 2) a multi-dimensional orthogonality metric to assess model adequacy between test and analysis, and 3) a prediction error metric to conduct sensor placement to minimize pressure prediction errors. Data from similar (nearly repeated) capsule drop tests shows significant variability in the measured pressure responses. When compared to expected variability using model predictions, it is demonstrated that the measured variability cannot be explained by the model under the current uncertainty assumptions.

  14. Reliability of a quantitative clinical posture assessment tool among persons with idiopathic scoliosis.

    PubMed

    Fortin, Carole; Feldman, Debbie Ehrmann; Cheriet, Farida; Gravel, Denis; Gauthier, Frédérique; Labelle, Hubert

    2012-03-01

    To determine overall, test-retest and inter-rater reliability of posture indices among persons with idiopathic scoliosis. A reliability study using two raters and two test sessions. Tertiary care paediatric centre. Seventy participants aged between 10 and 20 years with different types of idiopathic scoliosis (Cobb angle 15 to 60°) were recruited from the scoliosis clinic. Based on the XY co-ordinates of natural reference points (e.g., eyes) as well as markers placed on several anatomical landmarks, 32 angular and linear posture indices taken from digital photographs in the standing position were calculated from a specially developed software program. Generalisability theory served to estimate the reliability and standard error of measurement (SEM) for the overall, test-retest and inter-rater designs. Bland and Altman's method was also used to document agreement between sessions and raters. In the random design, dependability coefficients demonstrated a moderate level of reliability for six posture indices (ϕ=0.51 to 0.72) and a good level of reliability for 26 posture indices out of 32 (ϕ≥0.79). Error attributable to marker placement was negligible for most indices. Limits of agreement and SEM values were larger for shoulder protraction, trunk list, Q angle, cervical lordosis and scoliosis angles. The most reproducible indices were waist angles and knee valgus and varus. Posture can be assessed in a global fashion from photographs in persons with idiopathic scoliosis. Despite the good reliability of marker placement, other studies are needed to minimise measurement errors in order to provide a suitable tool for monitoring change in posture over time. Copyright © 2011 Chartered Society of Physiotherapy. Published by Elsevier Ltd. All rights reserved.

  15. Intelligent Document Gateway: A Service System Case Study and Analysis

    NASA Astrophysics Data System (ADS)

    Krishna, Vikas; Lelescu, Ana

    In today's fast paced world, it is necessary to process business ­documents expediently, accurately, and diligently. In other words, processing has to be fast, errors must be prevented (or caught and corrected quickly), and documents cannot be lost or misplaced. The failure to meet these criteria, depending on the type and purpose of the documents, can have serious business, legal, or safety consequences. In this paper, we evaluated a B2B order placement service system that allows clients to place orders for products and services over a network. We describe the order placement service before and after deploying the Intelligent Document Gateway (IDG), a document-centric business process automation technology from IBM Research. Using service science perspective and service systems frameworks, we provide an analysis of how IDG improved the value proposition for both the service providers and service clients.

  16. Multi-projector auto-calibration and placement optimization for non-planar surfaces

    NASA Astrophysics Data System (ADS)

    Li, Dong; Xie, Jinghui; Zhao, Lu; Zhou, Lijing; Weng, Dongdong

    2015-10-01

    Non-planar projection has been widely applied in virtual reality and digital entertainment and exhibitions because of its flexible layout and immersive display effects. Compared with planar projection, a non-planar projection is more difficult to achieve because projector calibration and image distortion correction are difficult processes. This paper uses a cylindrical screen as an example to present a new method for automatically calibrating a multi-projector system in a non-planar environment without using 3D reconstruction. This method corrects the geometric calibration error caused by the screen's manufactured imperfections, such as an undulating surface or a slant in the vertical plane. In addition, based on actual projection demand, this paper presents the overall performance evaluation criteria for the multi-projector system. According to these criteria, we determined the optimal placement for the projectors. This method also extends to surfaces that can be parameterized, such as spheres, ellipsoids, and paraboloids, and demonstrates a broad applicability.

  17. Factors affecting the accuracy of near-infrared spectroscopy concentration calculations for focal changes in oxygenation parameters

    NASA Technical Reports Server (NTRS)

    Strangman, Gary; Franceschini, Maria Angela; Boas, David A.; Sutton, J. P. (Principal Investigator)

    2003-01-01

    Near-infrared spectroscopy (NIRS) can be used to noninvasively measure changes in the concentrations of oxy- and deoxyhemoglobin in tissue. We have previously shown that while global changes can be reliably measured, focal changes can produce erroneous estimates of concentration changes (NeuroImage 13 (2001), 76). Here, we describe four separate sources for systematic error in the calculation of focal hemoglobin changes from NIRS data and use experimental methods and Monte Carlo simulations to examine the importance and mitigation methods of each. The sources of error are: (1). the absolute magnitudes and relative differences in pathlength factors as a function of wavelength, (2). the location and spatial extent of the absorption change with respect to the optical probe, (3). possible differences in the spatial distribution of hemoglobin species, and (4). the potential for simultaneous monitoring of multiple regions of activation. We found wavelength selection and optode placement to be important variables in minimizing such errors, and our findings indicate that appropriate experimental procedures could reduce each of these errors to a small fraction (<10%) of the observed concentration changes.

  18. 4D modeling in high-rise construction

    NASA Astrophysics Data System (ADS)

    Balakina, Anastasiya; Simankina, Tatyana; Lukinov, Vitaly

    2018-03-01

    High-rise construction is a complex construction process, requiring the use of more perfected and sophisticated tools for design, planning and construction management. The use of BIM-technologies allows minimizing the risks associated with design errors and errors that occur during construction. This article discusses a visual planning method using the 4D model, which allows the project team to create an accurate and complete construction plan, which is much more difficult to achieve with the help of traditional planning methods. The use of the 4D model in the construction of a 70-story building allowed to detect spatial and temporal errors before the start of construction work. In addition to identifying design errors, 4D modeling has allowed to optimize the construction, as follows: to optimize the operation of cranes, the placement of building structures and materials at various stages of construction, to optimize the organization of work performance, as well as to monitor the activities related to the preparation of the construction site for compliance with labor protection and safety requirements, which resulted in saving money and time.

  19. Quotation accuracy in medical journal articles—a systematic review and meta-analysis

    PubMed Central

    Jergas, Hannah

    2015-01-01

    Background. Quotations and references are an indispensable element of scientific communication. They should support what authors claim or provide important background information for readers. Studies indicate, however, that quotations not serving their purpose—quotation errors—may be prevalent. Methods. We carried out a systematic review, meta-analysis and meta-regression of quotation errors, taking account of differences between studies in error ascertainment. Results. Out of 559 studies screened we included 28 in the main analysis, and estimated major, minor and total quotation error rates of 11,9%, 95% CI [8.4, 16.6] 11.5% [8.3, 15.7], and 25.4% [19.5, 32.4]. While heterogeneity was substantial, even the lowest estimate of total quotation errors was considerable (6.7%). Indirect references accounted for less than one sixth of all quotation problems. The findings remained robust in a number of sensitivity and subgroup analyses (including risk of bias analysis) and in meta-regression. There was no indication of publication bias. Conclusions. Readers of medical journal articles should be aware of the fact that quotation errors are common. Measures against quotation errors include spot checks by editors and reviewers, correct placement of citations in the text, and declarations by authors that they have checked cited material. Future research should elucidate if and to what degree quotation errors are detrimental to scientific progress. PMID:26528420

  20. National Program for Inspection of Non-Federal Dams. Merino Pond Dam (MA 00110), Thames River Basin, Dudley, Massachusetts. Phase I Inspection Report.

    DTIC Science & Technology

    1979-09-01

    of slm~ lu THAMES RIVER BASIN 00 DUDLEY, MASSACHUSETTS 0 0 in MERINO POND DAM MA 00110 0 PHASE I INSPECTION REPORT 0 NATIONAL DAM INSPECTION PROGRAM ...NATIONAL PROGRAM FOR INSPECTION OF NON-FEDERAL , e, .* f. ,,,-Ue I,. h TNw@ e 6, CONTACT OR IAUNT ONUWSaEPe* U.S. AMY CORPS OF ENGINEERS NEW ENGLAND...SAaUmN el ame 6 am vel NSON* Odlmwmn ba 00-0 o6. oll.I,,NIA*v mOTE& Cover program reads: Phase I Inspection Report, National Dam Inspection Program

  1. New statistical learning theory paradigms adapted to breast cancer diagnosis/classification using image and non-image clinical data.

    PubMed

    Land, Walker H; Heine, John J; Raway, Tom; Mizaku, Alda; Kovalchuk, Nataliya; Yang, Jack Y; Yang, Mary Qu

    2008-01-01

    The automated decision paradigms presented in this work address the false positive (FP) biopsy occurrence in diagnostic mammography. An EP/ES stochastic hybrid and two kernelized Partial Least Squares (K-PLS) paradigms were investigated with following studies: methodology performance comparisonsautomated diagnostic accuracy assessments with two data sets. The findings showed: the new hybrid produced comparable results more rapidlythe new K-PLS paradigms train and operate Essentially in real time for the data sets studied. Both advancements are essential components for eventually achieving the FP reduction goal, while maintaining acceptable diagnostic sensitivities.

  2. New statistical learning theory paradigms adapted to breast cancer diagnosis/classification using image and non-image clinical data

    PubMed Central

    Raway, Tom; Mizaku, Alda; Kovalchuk, Nataliya; Yang, Jack Y.; Yang, Mary Qu

    2015-01-01

    The automated decision paradigms presented in this work address the false positive (FP) biopsy occurrence in diagnostic mammography. An EP/ES stochastic hybrid and two kernelized Partial Least Squares (K-PLS) paradigms were investigated with following studies: methodology performance comparisonsautomated diagnostic accuracy assessments with two data sets. The findings showed: the new hybrid produced comparable results more rapidlythe new K-PLS paradigms train and operate Essentially in real time for the data sets studied. Both advancements are essential components for eventually achieving the FP reduction goal, while maintaining acceptable diagnostic sensitivities. PMID:26430470

  3. Integrated manufacturing flow for selective-etching SADP/SAQP

    NASA Astrophysics Data System (ADS)

    Ali, Rehab Kotb; Fatehy, Ahmed Hamed; Word, James

    2018-03-01

    Printing cut mask in SAMP (Self Aligned Multi Patterning) is very challenging at advanced nodes. One of the proposed solutions is to print the cut shapes selectively. Which means the design is decomposed into mandrel tracks, Mandrel cuts and non-Mandrel cuts. The mandrel and non-Mandrel cuts are mutually independent which results in relaxing spacing constrains and as a consequence more dense metal lines. In this paper, we proposed the manufacturing flow of selective etching process. The results are quantified in terms of measuring PVBand, EPE and the number of hard bridging and pinching across the layout.

  4. Electrochemistry and Spectroelectrochemistry of 1,8-Naphthalene and 1,8- Anthracene-Linked Cofacial Binuclear Metallophthalocynanines. New Mixed Valence Metallopthalocyanines

    DTIC Science & Technology

    1990-05-10

    slope of a plot of peak current vs. sweep rate to the charge should be equal to nF/4RT, where n is the number of electrons per adsorbed species and...overlapping waves. b) Values ofAEp : (Ep. - Epe) are given at a potential sweep rate of 50 mV/s. c) data fom ref.8g. d) Potentials are approximate because...cyclic voltametry at 200, 100, 50 and 20 mV/s, Average data being E : (Eps + Epc)/2 are reported. Data in parenthesis are estimated from overlapping

  5. Psycho-Motor and Error Enabled Simulations: Modeling Vulnerable Skills in the Pre-Mastery Phase

    DTIC Science & Technology

    2016-04-01

    participants. Multiple abstracts and posters were created for surgical conferences attended. These works concentrated on data from pre and post ...analyzed to give every participant a perspective of the smallest difference in stiffness they could differentiate. Based on the results the tests were...camera was affixed to a post mounted to this station’s table to capture a close-up view of the participant’s placement of needles on the simulation

  6. The relationship between simulation in nursing education and medication safety.

    PubMed

    Sears, Kimberley; Goldsworthy, Sandra; Goodman, William M

    2010-01-01

    This experimental study examined whether the use of clinical simulation in nursing education could help reduce medication errors. Fifty-four student volunteers were randomly assigned to an experimental (treatment) group (24 students) or a clinical control group (30 students). The treatment replaced some early-term clinical placement hours with a simulated clinical experience. The control group had all normally scheduled clinical hours. Treatment occurred prior to opportunities for medication administration. Copyright 2010, SLACK Incorporated.

  7. MEF and MEB Red Teams: Required Conditions and Placement Options

    DTIC Science & Technology

    2013-04-16

    aids decision making and influences how the organization views the problems it is facing. Discussion : The 2010 Commandant’s Planning Guidance...the Regional Command (South West) Red Team. Throughout this time, ‘discovery learning ’ and trial and error were the means in which I gained an...who I had the pleasure of working with and learning from during my time as a red teamer. Most importantly, I would like to thank my family for their

  8. Surface characterization protocol for precision aspheric optics

    NASA Astrophysics Data System (ADS)

    Sarepaka, RamaGopal V.; Sakthibalan, Siva; Doodala, Somaiah; Panwar, Rakesh S.; Kotaria, Rajendra

    2017-10-01

    In Advanced Optical Instrumentation, Aspherics provide an effective performance alternative. The aspheric fabrication and surface metrology, followed by aspheric design are complementary iterative processes for Precision Aspheric development. As in fabrication, a holistic approach of aspheric surface characterization is adopted to evaluate actual surface error and to aim at the deliverance of aspheric optics with desired surface quality. Precision optical surfaces are characterized by profilometry or by interferometry. Aspheric profiles are characterized by contact profilometers, through linear surface scans to analyze their Form, Figure and Finish errors. One must ensure that, the surface characterization procedure does not add to the resident profile errors (generated during the aspheric surface fabrication). This presentation examines the errors introduced post-surface generation and during profilometry of aspheric profiles. This effort is to identify sources of errors and is to optimize the metrology process. The sources of error during profilometry may be due to: profilometer settings, work-piece placement on the profilometer stage, selection of zenith/nadir points of aspheric profiles, metrology protocols, clear aperture - diameter analysis, computational limitations of the profiler and the software issues etc. At OPTICA, a PGI 1200 FTS contact profilometer (Taylor-Hobson make) is used for this study. Precision Optics of various profiles are studied, with due attention to possible sources of errors during characterization, with multi-directional scan approach for uniformity and repeatability of error estimation. This study provides an insight of aspheric surface characterization and helps in optimal aspheric surface production methodology.

  9. Image-guided intracranial cannula placement for awake in vivo microdialysis in nonhuman primates

    NASA Astrophysics Data System (ADS)

    Chen, Antong; Bone, Ashleigh; Hines, Catherine D. G.; Dogdas, Belma; Montgomery, Tamara O.; Michener, Maria; Winkelmann, Christopher T.; Ghafurian, Soheil; Lubbers, Laura S.; Renger, John; Bagchi, Ansuman; Uslaner, Jason M.; Johnson, Colena; Zariwala, Hatim A.

    2016-03-01

    Intracranial microdialysis is used for sampling neurochemicals and large peptides along with their metabolites from the interstitial fluid (ISF) of the brain. The ability to perform this in nonhuman primates (NHP) e.g., rhesus could improve the prediction of pharmacokinetic (PK) and pharmacodynamics (PD) action of drugs in human. However, microdialysis in rhesus brains is not as routinely performed as in rodents. One challenge is that the precise intracranial probe placement in NHP brains is difficult due to the richness of the anatomical structure and the variability of the size and shape of brains across animals. Also, a repeatable and reproducible ISF sampling from the same animal is highly desirable when combined with cognitive behaviors or other longitudinal study end points. Toward that end, we have developed a semi-automatic flexible neurosurgical method employing MR and CT imaging to (a) derive coordinates for permanent guide cannula placement in mid-brain structures and (b) fabricate a customized recording chamber to implant above the skull for enclosing and safeguarding access to the cannula for repeated experiments. In order to place the intracranial guide cannula in each subject, the entry points in the skull and the depth in the brain were derived using co-registered images acquired from MR and CT scans. The anterior/posterior (A/P) and medial-lateral (M/L) rotation in the pose of the animal was corrected in the 3D image to appropriately represent the pose used in the stereotactic frame. An array of implanted fiducial markers was used to transform stereotactic coordinates to the images. The recording chamber was custom fabricated using computer-aided design (CAD), such that it would fit the contours of the individual skull with minimum error. The chamber also helped in guiding the cannula through the entry points down a trajectory into the depth of the brain. We have validated our method in four animals and our results indicate average placement error of cannula to be 1.20 +/- 0.68 mm of the targeted positions. The approach employed here for derivation of the coordinates, surgical implantation and post implant validation is built using traditional access to surgical and imaging methods without the necessity of intra-operative imaging. The validation of our method lends support to its wider application in most nonhuman primate laboratories with onsite MR and CT imaging capabilities.

  10. Effects of camera location on the reconstruction of 3D flare trajectory with two cameras

    NASA Astrophysics Data System (ADS)

    Özsaraç, Seçkin; Yeşilkaya, Muhammed

    2015-05-01

    Flares are used as valuable electronic warfare assets for the battle against infrared guided missiles. The trajectory of the flare is one of the most important factors that determine the effectiveness of the counter measure. Reconstruction of the three dimensional (3D) position of a point, which is seen by multiple cameras, is a common problem. Camera placement, camera calibration, corresponding pixel determination in between the images of different cameras and also the triangulation algorithm affect the performance of 3D position estimation. In this paper, we specifically investigate the effects of camera placement on the flare trajectory estimation performance by simulations. Firstly, 3D trajectory of a flare and also the aircraft, which dispenses the flare, are generated with simple motion models. Then, we place two virtual ideal pinhole camera models on different locations. Assuming the cameras are tracking the aircraft perfectly, the view vectors of the cameras are computed. Afterwards, using the view vector of each camera and also the 3D position of the flare, image plane coordinates of the flare on both cameras are computed using the field of view (FOV) values. To increase the fidelity of the simulation, we have used two sources of error. One is used to model the uncertainties in the determination of the camera view vectors, i.e. the orientations of the cameras are measured noisy. Second noise source is used to model the imperfections of the corresponding pixel determination of the flare in between the two cameras. Finally, 3D position of the flare is estimated using the corresponding pixel indices, view vector and also the FOV of the cameras by triangulation. All the processes mentioned so far are repeated for different relative camera placements so that the optimum estimation error performance is found for the given aircraft and are trajectories.

  11. Impact of a preoperatively estimated prostate volume using transrectal ultrasonography on surgical and oncological outcomes in a single surgeon's experience with robot-assisted radical prostatectomy.

    PubMed

    Hirasawa, Yosuke; Ohno, Yoshio; Nakashima, Jun; Shimodaira, Kenji; Hashimoto, Takeshi; Gondo, Tatsuo; Ohori, Makoto; Tachibana, Masaaki; Yoshioka, Kunihiko

    2016-09-01

    To assess the impact of preoperatively estimated prostate volume (PV) using transrectal ultrasonography (TRUS) on surgical and oncological outcomes in robot-assisted radical prostatectomy (RARP). We analyzed the experience of a single surgeon at our hospital who performed 436 RARPs without neoadjuvant hormone therapy between August 2006 and December 2013. Patients were divided into three groups according to their preoperative PV calculated using TRUS (PV ≤ 20 cm(3): group 1, n = 61; 20 < PV < 50 cm(3): group 2, n = 303; PV ≥ 50 cm(3): group 3, n = 72). Blood loss was significantly higher in group 3 than in group 1 and group 2. In stage pT2 patients, the rate of positive surgical margin (PSM) was significantly lower in group 3 than in group 1. In addition, perioperative complications significantly increased with increasing PV, while the extraprostatic extension (EPE) rate significantly decreased with increasing PV. The preoperative biopsy Gleason score, prostate-specific antigen (PSA) density, and clinical T2 stage were inversely correlated with increasing PV. Biochemical recurrence-free survival after RARP was significantly lower in group 1 than in groups 2 and 3. A large prostate size was significantly associated with increased blood loss and a higher rate of perioperative complications. A small prostate size was associated with a higher PSM rate, PSA density, Gleason score, EPE rate, and biochemical recurrence rate. These results suggest that RARP was technically challenging in patients with large prostates, whereas small prostates were associated with unfavorable oncological outcomes.

  12. Target motion tracking in MRI-guided transrectal robotic prostate biopsy.

    PubMed

    Tadayyon, Hadi; Lasso, Andras; Kaushal, Aradhana; Guion, Peter; Fichtinger, Gabor

    2011-11-01

    MRI-guided prostate needle biopsy requires compensation for organ motion between target planning and needle placement. Two questions are studied and answered in this paper: 1) is rigid registration sufficient in tracking the targets with an error smaller than the clinically significant size of prostate cancer and 2) what is the effect of the number of intraoperative slices on registration accuracy and speed? we propose multislice-to-volume registration algorithms for tracking the biopsy targets within the prostate. Three orthogonal plus additional transverse intraoperative slices are acquired in the approximate center of the prostate and registered with a high-resolution target planning volume. Both rigid and deformable scenarios were implemented. Both simulated and clinical MRI-guided robotic prostate biopsy data were used to assess tracking accuracy. average registration errors in clinical patient data were 2.6 mm for the rigid algorithm and 2.1 mm for the deformable algorithm. rigid tracking appears to be promising. Three tracking slices yield significantly high registration speed with an affordable error.

  13. Genetic evolutionary taboo search for optimal marker placement in infrared patient setup

    NASA Astrophysics Data System (ADS)

    Riboldi, M.; Baroni, G.; Spadea, M. F.; Tagaste, B.; Garibaldi, C.; Cambria, R.; Orecchia, R.; Pedotti, A.

    2007-09-01

    In infrared patient setup adequate selection of the external fiducial configuration is required for compensating inner target displacements (target registration error, TRE). Genetic algorithms (GA) and taboo search (TS) were applied in a newly designed approach to optimal marker placement: the genetic evolutionary taboo search (GETS) algorithm. In the GETS paradigm, multiple solutions are simultaneously tested in a stochastic evolutionary scheme, where taboo-based decision making and adaptive memory guide the optimization process. The GETS algorithm was tested on a group of ten prostate patients, to be compared to standard optimization and to randomly selected configurations. The changes in the optimal marker configuration, when TRE is minimized for OARs, were specifically examined. Optimal GETS configurations ensured a 26.5% mean decrease in the TRE value, versus 19.4% for conventional quasi-Newton optimization. Common features in GETS marker configurations were highlighted in the dataset of ten patients, even when multiple runs of the stochastic algorithm were performed. Including OARs in TRE minimization did not considerably affect the spatial distribution of GETS marker configurations. In conclusion, the GETS algorithm proved to be highly effective in solving the optimal marker placement problem. Further work is needed to embed site-specific deformation models in the optimization process.

  14. [Navigation in implantology: Accuracy assessment regarding the literature].

    PubMed

    Barrak, Ibrahim Ádám; Varga, Endre; Piffko, József

    2016-06-01

    Our objective was to assess the literature regarding the accuracy of the different static guided systems. After applying electronic literature search we found 661 articles. After reviewing 139 articles, the authors chose 52 articles for full-text evaluation. 24 studies involved accuracy measurements. Fourteen of our selected references were clinical and ten of them were in vitro (modell or cadaver). Variance-analysis (Tukey's post-hoc test; p < 0.05) was conducted to summarize the selected publications. Regarding 2819 results the average mean error at the entry point was 0.98 mm. At the level of the apex the average deviation was 1.29 mm while the mean of the angular deviation was 3,96 degrees. Significant difference could be observed between the two methods of implant placement (partially and fully guided sequence) in terms of deviation at the entry point, apex and angular deviation. Different levels of quality and quantity of evidence were available for assessing the accuracy of the different computer-assisted implant placement. The rapidly evolving field of digital dentistry and the new developments will further improve the accuracy of guided implant placement. In the interest of being able to draw dependable conclusions and for the further evaluation of the parameters used for accuracy measurements, randomized, controlled single or multi-centered clinical trials are necessary.

  15. Fast dose kernel interpolation using Fourier transform with application to permanent prostate brachytherapy dosimetry.

    PubMed

    Liu, Derek; Sloboda, Ron S

    2014-05-01

    Boyer and Mok proposed a fast calculation method employing the Fourier transform (FT), for which calculation time is independent of the number of seeds but seed placement is restricted to calculation grid points. Here an interpolation method is described enabling unrestricted seed placement while preserving the computational efficiency of the original method. The Iodine-125 seed dose kernel was sampled and selected values were modified to optimize interpolation accuracy for clinically relevant doses. For each seed, the kernel was shifted to the nearest grid point via convolution with a unit impulse, implemented in the Fourier domain. The remaining fractional shift was performed using a piecewise third-order Lagrange filter. Implementation of the interpolation method greatly improved FT-based dose calculation accuracy. The dose distribution was accurate to within 2% beyond 3 mm from each seed. Isodose contours were indistinguishable from explicit TG-43 calculation. Dose-volume metric errors were negligible. Computation time for the FT interpolation method was essentially the same as Boyer's method. A FT interpolation method for permanent prostate brachytherapy TG-43 dose calculation was developed which expands upon Boyer's original method and enables unrestricted seed placement. The proposed method substantially improves the clinically relevant dose accuracy with negligible additional computation cost, preserving the efficiency of the original method.

  16. Dataset for Testing Contamination Source Identification Methods for Water Distribution Networks

    EPA Pesticide Factsheets

    This dataset includes the results of a simulation study using the source inversion techniques available in the Water Security Toolkit. The data was created to test the different techniques for accuracy, specificity, false positive rate, and false negative rate. The tests examined different parameters including measurement error, modeling error, injection characteristics, time horizon, network size, and sensor placement. The water distribution system network models that were used in the study are also included in the dataset. This dataset is associated with the following publication:Seth, A., K. Klise, J. Siirola, T. Haxton , and C. Laird. Testing Contamination Source Identification Methods for Water Distribution Networks. Journal of Environmental Division, Proceedings of American Society of Civil Engineers. American Society of Civil Engineers (ASCE), Reston, VA, USA, ., (2016).

  17. One-kilohertz eye tracker and active intraoperative torsion detection in the NIDEK CXIII and Quest excimer lasers.

    PubMed

    Waring, George O

    2009-10-01

    To describe recent technological additions to the NIDEK CXIII and Quest excimer lasers. A summary article with data from previous published studies outlining the benefits of newer technology. The addition of a 1-kHz infrared eye tracker decreased the spread of laser spot placement from a mean of 228.79 microm without a tracker to 38.47 microm with the eye tracker. The addition of real-time torsion error correction produced a statistically significantly lower cylinder dispersion, mean manifest refractive cylinder, and error of angle postoperatively in eyes that underwent LASIK. The incorporation of an ultrahigh speed eye tracker and active cyclotorsion correction surpasses the minimal technology criteria required for accurate wavefront-based ablations. Copyright 2009, SLACK Incorporated.

  18. Canine sacroiliac luxation: anatomic study of the craniocaudal articular surface angulation of the sacrum to define a safe corridor in the dorsal plane for placement of screws used for fixation in lag fashion.

    PubMed

    Bowlt, Kelly L; Shales, Christopher J

    2011-01-01

    To define a safe corridor in the dorsal plane relative to the articular surface for placement of a single screw in lag fashion to achieve stabilization of sacroiliac luxation in the dog. Cadaveric study. Dorsoventral radiographs of denuded canine sacra (n=49) were taken to determine the safe corridor in the craniocaudal plane, and the maximum, optimum and minimum angles were calculated that would allow a screw inserted in lag fashion to engage at least 60% of the width of the sacral body without cranial or caudal penetration through the bone. The mean safe corridor in the dorsal plane is ∼24° wide. Mean craniocaudal minimum, optimum and maximum drill angles from the drill start point were 88°, 100°, and 111° from the articular surface, respectively. No single angle will completely avoid risk of screw penetration beyond the safe corridor cranially and caudally. There is sufficient anatomic variation between different canine sacra that a single angle cannot be recommended for screw placement in the dorsal plane. A standard angle cannot be recommended for screw placement in lag fashion within the canine sacrum in the dorsal plane. Because of the narrow width of the safe corridor, preoperative measurements on radiographs are recommended and a range of angled drill guides may be useful to decrease surgeon margin of error. © Copyright 2010 by The American College of Veterinary Surgeons.

  19. Sub-100nm, Maskless Deep-UV Zone-Plate Array Lithography

    DTIC Science & Technology

    2004-05-07

    The basic idea is to use fiducial grids, fabricated using interference lithography (or a derivative thereof) to determine the placement of features...sensed, and corrections are fed back to the beam-control electronics to cancel errors in the beam’s position. The virtue of interference lithography ...Sub-100nm, Maskless Deep-UV Zone-Plate Array Lithography Project Period: March 1, 2001 – February 28, 2004 F i n a l R e p o r t Army Research

  20. Case-related factors affecting cutting errors of the proximal tibia in total knee arthroplasty assessed by computer navigation.

    PubMed

    Tsukeoka, Tadashi; Tsuneizumi, Yoshikazu; Yoshino, Kensuke; Suzuki, Mashiko

    2018-05-01

    The aim of this study was to determine factors that contribute to bone cutting errors of conventional instrumentation for tibial resection in total knee arthroplasty (TKA) as assessed by an image-free navigation system. The hypothesis is that preoperative varus alignment is a significant contributory factor to tibial bone cutting errors. This was a prospective study of a consecutive series of 72 TKAs. The amount of the tibial first-cut errors with reference to the planned cutting plane in both coronal and sagittal planes was measured by an image-free computer navigation system. Multiple regression models were developed with the amount of tibial cutting error in the coronal and sagittal planes as dependent variables and sex, age, disease, height, body mass index, preoperative alignment, patellar height (Insall-Salvati ratio) and preoperative flexion angle as independent variables. Multiple regression analysis showed that sex (male gender) (R = 0.25 p = 0.047) and preoperative varus alignment (R = 0.42, p = 0.001) were positively associated with varus tibial cutting errors in the coronal plane. In the sagittal plane, none of the independent variables was significant. When performing TKA in varus deformity, careful confirmation of the bone cutting surface should be performed to avoid varus alignment. The results of this study suggest technical considerations that can help a surgeon achieve more accurate component placement. IV.

  1. A modified technique to reduce tibial keel cutting errors during an Oxford unicompartmental knee arthroplasty.

    PubMed

    Inui, Hiroshi; Taketomi, Shuji; Tahara, Keitarou; Yamagami, Ryota; Sanada, Takaki; Tanaka, Sakae

    2017-03-01

    Bone cutting errors can cause malalignment of unicompartmental knee arthroplasties (UKA). Although the extent of tibial malalignment due to horizontal cutting errors has been well reported, there is a lack of studies evaluating malalignment as a consequence of keel cutting errors, particularly in the Oxford UKA. The purpose of this study was to examine keel cutting errors during Oxford UKA placement using a navigation system and to clarify whether two different tibial keel cutting techniques would have different error rates. The alignment of the tibial cut surface after a horizontal osteotomy and the surface of the tibial trial component was measured with a navigation system. Cutting error was defined as the angular difference between these measurements. The following two techniques were used: the standard "pushing" technique in 83 patients (group P) and a modified "dolphin" technique in 41 patients (group D). In all 123 patients studied, the mean absolute keel cutting error was 1.7° and 1.4° in the coronal and sagittal planes, respectively. In group P, there were 22 outlier patients (27 %) in the coronal plane and 13 (16 %) in the sagittal plane. Group D had three outlier patients (8 %) in the coronal plane and none (0 %) in the sagittal plane. Significant differences were observed in the outlier ratio of these techniques in both the sagittal (P = 0.014) and coronal (P = 0.008) planes. Our study demonstrated overall keel cutting errors of 1.7° in the coronal plane and 1.4° in the sagittal plane. The "dolphin" technique was found to significantly reduce keel cutting errors on the tibial side. This technique will be useful for accurate component positioning and therefore improve the longevity of Oxford UKAs. Retrospective comparative study, Level III.

  2. How Angular Velocity Features and Different Gyroscope Noise Types Interact and Determine Orientation Estimation Accuracy.

    PubMed

    Pasciuto, Ilaria; Ligorio, Gabriele; Bergamini, Elena; Vannozzi, Giuseppe; Sabatini, Angelo Maria; Cappozzo, Aurelio

    2015-09-18

    In human movement analysis, 3D body segment orientation can be obtained through the numerical integration of gyroscope signals. These signals, however, are affected by errors that, for the case of micro-electro-mechanical systems, are mainly due to: constant bias, scale factor, white noise, and bias instability. The aim of this study is to assess how the orientation estimation accuracy is affected by each of these disturbances, and whether it is influenced by the angular velocity magnitude and 3D distribution across the gyroscope axes. Reference angular velocity signals, either constant or representative of human walking, were corrupted with each of the four noise types within a simulation framework. The magnitude of the angular velocity affected the error in the orientation estimation due to each noise type, except for the white noise. Additionally, the error caused by the constant bias was also influenced by the angular velocity 3D distribution. As the orientation error depends not only on the noise itself but also on the signal it is applied to, different sensor placements could enhance or mitigate the error due to each disturbance, and special attention must be paid in providing and interpreting measures of accuracy for orientation estimation algorithms.

  3. How Angular Velocity Features and Different Gyroscope Noise Types Interact and Determine Orientation Estimation Accuracy

    PubMed Central

    Pasciuto, Ilaria; Ligorio, Gabriele; Bergamini, Elena; Vannozzi, Giuseppe; Sabatini, Angelo Maria; Cappozzo, Aurelio

    2015-01-01

    In human movement analysis, 3D body segment orientation can be obtained through the numerical integration of gyroscope signals. These signals, however, are affected by errors that, for the case of micro-electro-mechanical systems, are mainly due to: constant bias, scale factor, white noise, and bias instability. The aim of this study is to assess how the orientation estimation accuracy is affected by each of these disturbances, and whether it is influenced by the angular velocity magnitude and 3D distribution across the gyroscope axes. Reference angular velocity signals, either constant or representative of human walking, were corrupted with each of the four noise types within a simulation framework. The magnitude of the angular velocity affected the error in the orientation estimation due to each noise type, except for the white noise. Additionally, the error caused by the constant bias was also influenced by the angular velocity 3D distribution. As the orientation error depends not only on the noise itself but also on the signal it is applied to, different sensor placements could enhance or mitigate the error due to each disturbance, and special attention must be paid in providing and interpreting measures of accuracy for orientation estimation algorithms. PMID:26393606

  4. Real cell overlay measurement through design based metrology

    NASA Astrophysics Data System (ADS)

    Yoo, Gyun; Kim, Jungchan; Park, Chanha; Lee, Taehyeong; Ji, Sunkeun; Jo, Gyoyeon; Yang, Hyunjo; Yim, Donggyu; Yamamoto, Masahiro; Maruyama, Kotaro; Park, Byungjun

    2014-04-01

    Until recent device nodes, lithography has been struggling to improve its resolution limit. Even though next generation lithography technology is now facing various difficulties, several innovative resolution enhancement technologies, based on 193nm wavelength, were introduced and implemented to keep the trend of device scaling. Scanner makers keep developing state-of-the-art exposure system which guarantees higher productivity and meets a more aggressive overlay specification. "The scaling reduction of the overlay error has been a simple matter of the capability of exposure tools. However, it is clear that the scanner contributions may no longer be the majority component in total overlay performance. The ability to control correctable overlay components is paramount to achieve the desired performance.(2)" In a manufacturing fab, the overlay error, determined by a conventional overlay measurement: by using an overlay mark based on IBO and DBO, often does not represent the physical placement error in the cell area of a memory device. The mismatch may arise from the size or pitch difference between the overlay mark and the cell pattern. Pattern distortion, caused by etching or CMP, also can be a source of the mismatch. Therefore, the requirement of a direct overlay measurement in the cell pattern gradually increases in the manufacturing field, and also in the development level. In order to overcome the mismatch between conventional overlay measurement and the real placement error of layer to layer in the cell area of a memory device, we suggest an alternative overlay measurement method utilizing by design, based metrology tool. A basic concept of this method is shown in figure1. A CD-SEM measurement of the overlay error between layer 1 and 2 could be the ideal method but it takes too long time to extract a lot of data from wafer level. An E-beam based DBM tool provides high speed to cover the whole wafer with high repeatability. It is enabled by using the design as a reference for overlay measurement and a high speed scan system. In this paper, we have demonstrated that direct overlay measurement in the cell area can distinguish the mismatch exactly, instead of using overlay mark. This experiment was carried out for several critical layer in DRAM and Flash memory, using DBM(Design Based Metrology) tool, NGR2170™.

  5. Creating and evaluating a data-driven curriculum for central venous catheter placement.

    PubMed

    Duncan, James R; Henderson, Katherine; Street, Mandie; Richmond, Amy; Klingensmith, Mary; Beta, Elio; Vannucci, Andrea; Murray, David

    2010-09-01

    Central venous catheter placement is a common procedure with a high incidence of error. Other fields requiring high reliability have used Failure Mode and Effects Analysis (FMEA) to prioritize quality and safety improvement efforts. To use FMEA in the development of a formal, standardized curriculum for central venous catheter training. We surveyed interns regarding their prior experience with central venous catheter placement. A multidisciplinary team used FMEA to identify high-priority failure modes and to develop online and hands-on training modules to decrease the frequency, diminish the severity, and improve the early detection of these failure modes. We required new interns to complete the modules and tracked their progress using multiple assessments. Survey results showed new interns had little prior experience with central venous catheter placement. Using FMEA, we created a curriculum that focused on planning and execution skills and identified 3 priority topics: (1) retained guidewires, which led to training on handling catheters and guidewires; (2) improved needle access, which prompted the development of an ultrasound training module; and (3) catheter-associated bloodstream infections, which were addressed through training on maximum sterile barriers. Each module included assessments that measured progress toward recognition and avoidance of common failure modes. Since introducing this curriculum, the number of retained guidewires has fallen more than 4-fold. Rates of catheter-associated infections have not yet declined, and it will take time before ultrasound training will have a measurable effect. The FMEA provided a process for curriculum development. Precise definitions of failure modes for retained guidewires facilitated development of a curriculum that contributed to a dramatic decrease in the frequency of this complication. Although infections and access complications have not yet declined, failure mode identification, curriculum development, and monitored implementation show substantial promise for improving patient safety during placement of central venous catheters.

  6. Precision and Error of Three-dimensional Phenotypic Measures Acquired from 3dMD Photogrammetric Images

    PubMed Central

    Aldridge, Kristina; Boyadjiev, Simeon A.; Capone, George T.; DeLeon, Valerie B.; Richtsmeier, Joan T.

    2015-01-01

    The genetic basis for complex phenotypes is currently of great interest for both clinical investigators and basic scientists. In order to acquire a thorough understanding of the translation from genotype to phenotype, highly precise measures of phenotypic variation are required. New technologies, such as 3D photogrammetry are being implemented in phenotypic studies due to their ability to collect data rapidly and non-invasively. Before these systems can be broadly implemented the error associated with data collected from images acquired using these technologies must be assessed. This study investigates the precision, error, and repeatability associated with anthropometric landmark coordinate data collected from 3D digital photogrammetric images acquired with the 3dMDface System. Precision, error due to the imaging system, error due to digitization of the images, and repeatability are assessed in a sample of children and adults (N=15). Results show that data collected from images with the 3dMDface System are highly repeatable and precise. The average error associated with the placement of landmarks is sub-millimeter; both the error due to digitization and to the imaging system are very low. The few measures showing a higher degree of error include those crossing the labial fissure, which are influenced by even subtle movement of the mandible. These results suggest that 3D anthropometric data collected using the 3dMDface System are highly reliable and therefore useful for evaluation of clinical dysmorphology and surgery, analyses of genotype-phenotype correlations, and inheritance of complex phenotypes. PMID:16158436

  7. [Notes on the phlebologic work of Jean-Daniel Martinet].

    PubMed

    Sapin, G

    1977-01-01

    In homage to J.D. Martinet, the author, who was his collaborator for more than 25 years, surveys his phlebological work, so diverse and so multiple that it embraces all subjects of the venous pathology of the lower limbs. He cites 3 representative examples on different levels: the information and practical conclusions provided by phlebological investigations, especially retrograde; the classification of phlebitis migrans according to its course; the various problems presented by the surgery of varicose veins. Finally he emphasizes Martinet's qualities of loyalty and intellectual honesty, as well as his role as creator and director of a team (Broca, and later Epee de Bois).

  8. Investigating the Retention and Time-Course of Phonotactic Constraint Learning From Production Experience

    PubMed Central

    Warker, Jill A.

    2013-01-01

    Adults can rapidly learn artificial phonotactic constraints such as /f/ only occurs at the beginning of syllables by producing syllables that contain those constraints. This implicit learning is then reflected in their speech errors. However, second-order constraints in which the placement of a phoneme depends on another characteristic of the syllable (e.g., if the vowel is /æ/, /f/ occurs at the beginning of syllables and /s/ occurs at the end of syllables but if the vowel is /I/, the reverse is true) require a longer learning period. Two experiments question the transience of second-order learning and whether consolidation plays a role in learning phonological dependencies. Using speech errors as a measure of learning, Experiment 1 investigated the durability of learning, and Experiment 2 investigated the time-course of learning. Experiment 1 found that learning is still present in speech errors a week later. Experiment 2 looked at whether more time in the form of a consolidation period or more experience in the form of more trials was necessary for learning to be revealed in speech errors. Both consolidation and more trials led to learning; however, consolidation provided a more substantial benefit. PMID:22686839

  9. Overlay leaves litho: impact of non-litho processes on overlay and compensation

    NASA Astrophysics Data System (ADS)

    Ruhm, Matthias; Schulz, Bernd; Cotte, Eric; Seltmann, Rolf; Hertzsch, Tino

    2014-10-01

    According to the ITRS roadmap [1], the overlay requirement for the 28nm node is 8nm. If we compare this number with the performance given by tool vendors for their most advanced immersion systems (which is < 3nm), there seems to remain a large margin. Does that mean that today's leading edge Fab has an easy life? Unfortunately not, as other contributors affecting overlay are emerging. Mask contributions and so-called non-linear wafer distortions are known effects that can impact overlay quite significantly. Furthermore, it is often forgotten that downstream (post-litho) processes can impact the overlay as well. Thus, it can be required to compensate for the effects of subsequent processes already at the lithography operation. Within our paper, we will briefly touch on the wafer distortion topic and discuss the limitations of lithography compensation techniques such as higher order corrections versus solving the root cause of the distortions. The primary focus will be on the impact of the etch processes on the pattern placement error. We will show how individual layers can get affected differently by showing typical wafer signatures. However, in contrast to the above-mentioned wafer distortion topic, lithographic compensation techniques can be highly effective to reduce the placement error significantly towards acceptable levels (see Figure 1). Finally we will discuss the overall overlay budget for a 28nm contact to gate case by taking the impact of the individual process contributors into account.

  10. Surgical screw segmentation for mobile C-arm CT devices

    NASA Astrophysics Data System (ADS)

    Görres, Joseph; Brehler, Michael; Franke, Jochen; Wolf, Ivo; Vetter, Sven Y.; Grützner, Paul A.; Meinzer, Hans-Peter; Nabers, Diana

    2014-03-01

    Calcaneal fractures are commonly treated by open reduction and internal fixation. An anatomical reconstruction of involved joints is mandatory to prevent cartilage damage and premature arthritis. In order to avoid intraarticular screw placements, the use of mobile C-arm CT devices is required. However, for analyzing the screw placement in detail, a time-consuming human-computer interaction is necessary to navigate through 3D images and therefore to view a single screw in detail. Established interaction procedures of repeatedly positioning and rotating sectional planes are inconvenient and impede the intraoperative assessment of the screw positioning. To simplify the interaction with 3D images, we propose an automatic screw segmentation that allows for an immediate selection of relevant sectional planes. Our algorithm consists of three major steps. At first, cylindrical characteristics are determined from local gradient structures with the help of RANSAC. In a second step, a DBScan clustering algorithm is applied to group similar cylinder characteristics. Each detected cluster represents a screw, whose determined location is then refined by a cylinder-to-image registration in a third step. Our evaluation with 309 screws in 50 images shows robust and precise results. The algorithm detected 98% (303) of the screws correctly. Thirteen clusters led to falsely identified screws. The mean distance error for the screw tip was 0.8 +/- 0.8 mm and for the screw head 1.2 +/- 1 mm. The mean orientation error was 1.4 +/- 1.2 degrees.

  11. Comparison of computer-assisted surgery with conventional technique for the treatment of axial distal phalanx fractures in horses: an in vitro study.

    PubMed

    Andritzky, Juliane; Rossol, Melanie; Lischer, Christoph; Auer, Joerg A

    2005-01-01

    To compare the precision obtained with computer-assisted screw insertion for treatment of mid-sagittal articular fractures of the distal phalanx (P3) with results achieved with a conventional technique. In vitro experimental study. Thirty-two cadaveric equine limbs. Four groups of 8 limbs were studied. Either 1 or 2 screws were inserted perpendicular to an imaginary axial fracture of P3 using computer-assisted surgery (CAS) or conventional technique. Screw insertion time, predetermined screw length, inserted screw length, fit of the screw, and errors in placement were recorded. CAS technique took 15-20 minutes longer but resulted in greater precision of screw length and placement compared with the conventional technique. Improved precision in screw insertion with CAS makes insertion of 2 screws possible for repair of mid-sagittal P3 fractures. CAS although expensive improves precision in screw insertion into P3 and consequently should yield improved clinical outcome.

  12. Enabling full-field physics-based optical proximity correction via dynamic model generation

    NASA Astrophysics Data System (ADS)

    Lam, Michael; Clifford, Chris; Raghunathan, Ananthan; Fenger, Germain; Adam, Kostas

    2017-07-01

    As extreme ultraviolet lithography becomes closer to reality for high volume production, its peculiar modeling challenges related to both inter and intrafield effects have necessitated building an optical proximity correction (OPC) infrastructure that operates with field position dependency. Previous state-of-the-art approaches to modeling field dependency used piecewise constant models where static input models are assigned to specific x/y-positions within the field. OPC and simulation could assign the proper static model based on simulation-level placement. However, in the realm of 7 and 5 nm feature sizes, small discontinuities in OPC from piecewise constant model changes can cause unacceptable levels of edge placement errors. The introduction of dynamic model generation (DMG) can be shown to effectively avoid these dislocations by providing unique mask and optical models per simulation region, allowing a near continuum of models through the field. DMG allows unique models for electromagnetic field, apodization, aberrations, etc. to vary through the entire field and provides a capability to precisely and accurately model systematic field signatures.

  13. Automatic Quality Inspection of Percussion Cap Mass Production by Means of 3D Machine Vision and Machine Learning Techniques

    NASA Astrophysics Data System (ADS)

    Tellaeche, A.; Arana, R.; Ibarguren, A.; Martínez-Otzeta, J. M.

    The exhaustive quality control is becoming very important in the world's globalized market. One of these examples where quality control becomes critical is the percussion cap mass production. These elements must achieve a minimum tolerance deviation in their fabrication. This paper outlines a machine vision development using a 3D camera for the inspection of the whole production of percussion caps. This system presents multiple problems, such as metallic reflections in the percussion caps, high speed movement of the system and mechanical errors and irregularities in percussion cap placement. Due to these problems, it is impossible to solve the problem by traditional image processing methods, and hence, machine learning algorithms have been tested to provide a feasible classification of the possible errors present in the percussion caps.

  14. Ergonomic principles of task alignment, visual display, and direction of execution of laparoscopic bowel suturing.

    PubMed

    Emam, T A; Hanna, G; Cuschieri, A

    2002-02-01

    Laparoscopic suturing is technically a demanding skill in laparoscopic surgery. Ergonomic experimental studies provide objective information on the important factors and variables that govern optimal endoscopic suturing. Our objective was to determine the optimum physical alignment, visual display, and direction of intracorporeal laparoscopic bowel suturing using infrared motion analysis and telemetric electromyography (EMG) systems. Ten surgeons participated in the study; each sutured 50-mm porcine small bowel enterotomies toward and away from the surgeon in the vertical and horizontal bowel plane with either isoplanar (image display corresponds with actual lie of the bowel) or nonisoplanar (bowel displayed horizontally but mounted vertically in the trainer and vice versa) display. The end points were the placement error score, execution time, leakage pressure, motion analysis, and telemetric EMG parameters of the surgeon's dominant upper limb. Suturing was demonstrably easier in the vertical than in the horizontal plane, resulting in a better task quality (placement error score, p < 0.0001; leakage pressure, p < 0.005) and shorter execution time (p < 0.05). Nonisoplanar display of the surgical anatomy degrades performance in terms of both task efficiency and task quality. On motion analysis, a wider angle of excursion and lower angular velocity were observed during the vertical suturing with isoplaner display. Compared to horizontal suturing, supination at the wrist was significantly greater during vertical than horizontal suturing (p < 0.05). Within each category (vertical vs horizontal suturing), the direction of suturing (toward/away from the surgeon) did not influence the extent of pronation/ supination at the wrist. In line with the degraded performance, significantly more muscle work was expended during horizontal suturing. This affected the forearm flexors (p < 0.05), arm flexors and extensors (p < 0.005 and p < 0.05, respectively), and deltoid muscles (p < 0.005) and was accompanied by significantly more fatigue in the related muscles. Small bowel enterotomies sutured toward the surgeon in both the vertical and the horizontal planes exhibited less placement error score than when sutured away from the surgeon, with no significant difference in the motion analysis and EMG parameters. Optimal laparoscopic suturing (better task quality and reduced execution time) is achieved with vertical suturing toward the surgeon with isoplanar monitor display of the operative field. The poorer task performance observed during horizontal suturing is accompanied by more muscle work and fatigue, and it is not improved by monitor display of the enterotomy in the vertical plane.

  15. Foot placement relies on state estimation during visually guided walking.

    PubMed

    Maeda, Rodrigo S; O'Connor, Shawn M; Donelan, J Maxwell; Marigold, Daniel S

    2017-02-01

    As we walk, we must accurately place our feet to stabilize our motion and to navigate our environment. We must also achieve this accuracy despite imperfect sensory feedback and unexpected disturbances. In this study we tested whether the nervous system uses state estimation to beneficially combine sensory feedback with forward model predictions to compensate for these challenges. Specifically, subjects wore prism lenses during a visually guided walking task, and we used trial-by-trial variation in prism lenses to add uncertainty to visual feedback and induce a reweighting of this input. To expose altered weighting, we added a consistent prism shift that required subjects to adapt their estimate of the visuomotor mapping relationship between a perceived target location and the motor command necessary to step to that position. With added prism noise, subjects responded to the consistent prism shift with smaller initial foot placement error but took longer to adapt, compatible with our mathematical model of the walking task that leverages state estimation to compensate for noise. Much like when we perform voluntary and discrete movements with our arms, it appears our nervous systems uses state estimation during walking to accurately reach our foot to the ground. Accurate foot placement is essential for safe walking. We used computational models and human walking experiments to test how our nervous system achieves this accuracy. We find that our control of foot placement beneficially combines sensory feedback with internal forward model predictions to accurately estimate the body's state. Our results match recent computational neuroscience findings for reaching movements, suggesting that state estimation is a general mechanism of human motor control. Copyright © 2017 the American Physiological Society.

  16. The decision of out-of-home placement in residential care after parental neglect: Empirically testing a psychosocial model.

    PubMed

    Rodrigues, Leonor; Calheiros, Manuela; Pereira, Cícero

    2015-11-01

    Out-of-home placement decisions in residential care are complex, ambiguous and full of uncertainty, especially in cases of parental neglect. Literature on this topic is so far unable to understand and demonstrate the source of errors involved in those decisions and still fails to focus on professional's decision making process. Therefore, this work intends to test a socio-psychological model of decision-making that is a more integrated, dualistic and ecological version of the Theory of Planned Behavior's model. It describes the process through which the decision maker takes into account personal, contextual and social factors of the Decision-Making Ecology in the definition of his/her decision threshold. One hundred and ninety-five professionals from different Children and Youth Protection Units, throughout the Portuguese territory, participated in this online study. After reading a vignette of a (psychological and physical) neglect case toward a one-year-old child, participants were presented with a group of questions that measured worker's assessment of risk, intention, attitude, subjective norm, behavior control and beliefs toward residential care placement decision, as well as worker's behavior experience, emotions and family/child-related-values involved in that decision. A set of structural equation modeling analyses have proven the good fit of the proposed model. The intention to propose a residential care placement decision was determined by cognitive, social, affective, value-laden and experience variables and the perceived risk. Altogether our model explained 61% of professional's decision toward a parental neglect case. The theoretical and practical implications of these results are discussed, namely the importance of raising awareness about the existence of these biased psychosocial determinants. Copyright © 2015 Elsevier Ltd. All rights reserved.

  17. Two-spoke placement optimization under explicit specific absorption rate and power constraints in parallel transmission at ultra-high field.

    PubMed

    Dupas, Laura; Massire, Aurélien; Amadon, Alexis; Vignaud, Alexandre; Boulant, Nicolas

    2015-06-01

    The spokes method combined with parallel transmission is a promising technique to mitigate the B1(+) inhomogeneity at ultra-high field in 2D imaging. To date however, the spokes placement optimization combined with the magnitude least squares pulse design has never been done in direct conjunction with the explicit Specific Absorption Rate (SAR) and hardware constraints. In this work, the joint optimization of 2-spoke trajectories and RF subpulse weights is performed under these constraints explicitly and in the small tip angle regime. The problem is first considerably simplified by making the observation that only the vector between the 2 spokes is relevant in the magnitude least squares cost-function, thereby reducing the size of the parameter space and allowing a more exhaustive search. The algorithm starts from a set of initial k-space candidates and performs in parallel for all of them optimizations of the RF subpulse weights and the k-space locations simultaneously, under explicit SAR and power constraints, using an active-set algorithm. The dimensionality of the spoke placement parameter space being low, the RF pulse performance is computed for every location in k-space to study the robustness of the proposed approach with respect to initialization, by looking at the probability to converge towards a possible global minimum. Moreover, the optimization of the spoke placement is repeated with an increased pulse bandwidth in order to investigate the impact of the constraints on the result. Bloch simulations and in vivo T2(∗)-weighted images acquired at 7 T validate the approach. The algorithm returns simulated normalized root mean square errors systematically smaller than 5% in 10 s. Copyright © 2015 Elsevier Inc. All rights reserved.

  18. Optimal multi-type sensor placement for response and excitation reconstruction

    NASA Astrophysics Data System (ADS)

    Zhang, C. D.; Xu, Y. L.

    2016-01-01

    The need to perform dynamic response reconstruction always arises as the measurement of structural response is often limited to a few locations, especially for a large civil structure. Besides, it is usually very difficult, if not impossible, to measure external excitations under the operation condition of a structure. This study presents an algorithm for optimal placement of multi-type sensors, including strain gauges, displacement transducers and accelerometers, for the best reconstruction of responses of key structural components where there are no sensors installed and the best estimation of external excitations acting on the structure at the same time. The algorithm is developed in the framework of Kalman filter with unknown excitation, in which minimum-variance unbiased estimates of the generalized state of the structure and the external excitations are obtained by virtue of limited sensor measurements. The structural responses of key locations without sensors can then be reconstructed with the estimated generalized state and excitation. The asymptotic stability feature of the filter is utilized for optimal sensor placement. The number and spatial location of the multi-type sensors are determined by adding the optimal sensor which gains the maximal reduction of the estimation error of reconstructed responses. For the given mode number in response reconstruction and the given locations of external excitations, the optimal multi-sensor placement achieved by the proposed method is independent of the type and time evolution of external excitation. A simply-supported overhanging steel beam under multiple types of excitation is numerically studied to demonstrate the feasibility and superiority of the proposed method, and the experimental work is then carried out to testify the effectiveness of the proposed method.

  19. Optimal marker placement in hadrontherapy: intelligent optimization strategies with augmented Lagrangian pattern search.

    PubMed

    Altomare, Cristina; Guglielmann, Raffaella; Riboldi, Marco; Bellazzi, Riccardo; Baroni, Guido

    2015-02-01

    In high precision photon radiotherapy and in hadrontherapy, it is crucial to minimize the occurrence of geometrical deviations with respect to the treatment plan in each treatment session. To this end, point-based infrared (IR) optical tracking for patient set-up quality assessment is performed. Such tracking depends on external fiducial points placement. The main purpose of our work is to propose a new algorithm based on simulated annealing and augmented Lagrangian pattern search (SAPS), which is able to take into account prior knowledge, such as spatial constraints, during the optimization process. The SAPS algorithm was tested on data related to head and neck and pelvic cancer patients, and that were fitted with external surface markers for IR optical tracking applied for patient set-up preliminary correction. The integrated algorithm was tested considering optimality measures obtained with Computed Tomography (CT) images (i.e. the ratio between the so-called target registration error and fiducial registration error, TRE/FRE) and assessing the marker spatial distribution. Comparison has been performed with randomly selected marker configuration and with the GETS algorithm (Genetic Evolutionary Taboo Search), also taking into account the presence of organs at risk. The results obtained with SAPS highlight improvements with respect to the other approaches: (i) TRE/FRE ratio decreases; (ii) marker distribution satisfies both marker visibility and spatial constraints. We have also investigated how the TRE/FRE ratio is influenced by the number of markers, obtaining significant TRE/FRE reduction with respect to the random configurations, when a high number of markers is used. The SAPS algorithm is a valuable strategy for fiducial configuration optimization in IR optical tracking applied for patient set-up error detection and correction in radiation therapy, showing that taking into account prior knowledge is valuable in this optimization process. Further work will be focused on the computational optimization of the SAPS algorithm toward fast point-of-care applications. Copyright © 2014 Elsevier Inc. All rights reserved.

  20. Writing errors as a result of frontal dysfunction in Japanese patients with amyotrophic lateral sclerosis.

    PubMed

    Tsuji-Akimoto, Sachiko; Hamada, Shinsuke; Yabe, Ichiro; Tamura, Itaru; Otsuki, Mika; Kobashi, Syoji; Sasaki, Hidenao

    2010-12-01

    Loss of communication is a critical problem for advanced amyotrophic lateral sclerosis (ALS) patients. This loss of communication is mainly caused by severe dysarthria and disability of the dominant hand. However, reports show that about 50% of ALS patients have mild cognitive dysfunction, and there are a considerable number of case reports on Japanese ALS patients with agraphia. To clarify writing disabilities in non-demented ALS patients, eighteen non-demented ALS patients and 16 controls without neurological disorders were examined for frontal cognitive function and writing ability. To assess writing errors statistically, we scored them on their composition ability with the original writing error index (WEI). The ALS and control groups did not differ significantly with regard to age, years of education, or general cognitive level. Two patients could not write a letter because of disability of the dominant hand. The WEI and results of picture arrangement tests indicated significant impairment in the ALS patients. Auditory comprehension (Western Aphasia Battery; WAB IIC) and kanji dictation also showed mild impairment. Patients' writing errors consisted of both syntactic and letter-writing mistakes. Omission, substitution, displacement, and inappropriate placement of the phonic marks of kana were observed; these features have often been reported in Japanese patients with agraphia resulted from a frontal lobe lesion. The most frequent type of error was an omission of kana, the next most common was a missing subject. Writing errors might be a specific deficit for some non-demented ALS patients.

  1. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Meyer, Jeff, E-mail: jmeye3@utsouthwestern.ed; Bluett, Jaques; Amos, Richard

    Purpose: Conventional proton therapy with passively scattered beams is used to treat a number of tumor sites, including prostate cancer. Spot scanning proton therapy is a treatment delivery means that improves conformal coverage of the clinical target volume (CTV). Placement of individual spots within a target is dependent on traversed tissue density. Errors in patient alignment perturb dose distributions. Moreover, there is a need for a rational planning approach that can mitigate the dosimetric effect of random alignment errors. We propose a treatment planning approach and then analyze the consequences of various simulated alignment errors on prostate treatments. Methods andmore » Materials: Ten control patients with localized prostate cancer underwent treatment planning for spot scanning proton therapy. After delineation of the clinical target volume, a scanning target volume (STV) was created to guide dose coverage. Errors in patient alignment in two axes (rotational and yaw) as well as translational errors in the anteroposterior direction were then simulated, and dose to the CTV and normal tissues were reanalyzed. Results: Coverage of the CTV remained high even in the setting of extreme rotational and yaw misalignments. Changes in the rectum and bladder V45 and V70 were similarly minimal, except in the case of translational errors, where, as a result of opposed lateral beam arrangements, much larger dosimetric perturbations were observed. Conclusions: The concept of the STV as applied to spot scanning radiation therapy and as presented in this report leads to robust coverage of the CTV even in the setting of extreme patient misalignments.« less

  2. Minimally invasive surgical technique for tethered surgical drains

    PubMed Central

    Hess, Shane R; Satpathy, Jibanananda; Waligora, Andrew C; Ugwu-Oju, Obinna

    2017-01-01

    A feared complication of temporary surgical drain placement is from the technical error of accidentally suturing the surgical drain into the wound. Postoperative discovery of a tethered drain can frequently necessitate return to the operating room if it cannot be successfully removed with nonoperative techniques. Formal wound exploration increases anesthesia and infection risk as well as cost and is best avoided if possible. We present a minimally invasive surgical technique that can avoid the morbidity associated with a full surgical wound exploration to remove a tethered drain when other nonoperative techniques fail. PMID:28400669

  3. Accuracy of linear drilling in temporal bone using drill press system for minimally invasive cochlear implantation

    PubMed Central

    Balachandran, Ramya; Labadie, Robert F.

    2015-01-01

    Purpose A minimally invasive approach for cochlear implantation involves drilling a narrow linear path through the temporal bone from the skull surface directly to the cochlea for insertion of the electrode array without the need for an invasive mastoidectomy. Potential drill positioning errors must be accounted for to predict the effectiveness and safety of the procedure. The drilling accuracy of a system used for this procedure was evaluated in bone surrogate material under a range of clinically relevant parameters. Additional experiments were performed to isolate the error at various points along the path to better understand why deflections occur. Methods An experimental setup to precisely position the drill press over a target was used. Custom bone surrogate test blocks were manufactured to resemble the mastoid region of the temporal bone. The drilling error was measured by creating divots in plastic sheets before and after drilling and using a microscope to localize the divots. Results The drilling error was within the tolerance needed to avoid vital structures and ensure accurate placement of the electrode; however, some parameter sets yielded errors that may impact the effectiveness of the procedure when combined with other error sources. The error increases when the lateral stage of the path terminates in an air cell and when the guide bushings are positioned further from the skull surface. At contact points due to air cells along the trajectory, higher errors were found for impact angles of 45° and higher as well as longer cantilevered drill lengths. Conclusion The results of these experiments can be used to define more accurate and safe drill trajectories for this minimally invasive surgical procedure. PMID:26183149

  4. Accuracy of linear drilling in temporal bone using drill press system for minimally invasive cochlear implantation.

    PubMed

    Dillon, Neal P; Balachandran, Ramya; Labadie, Robert F

    2016-03-01

    A minimally invasive approach for cochlear implantation involves drilling a narrow linear path through the temporal bone from the skull surface directly to the cochlea for insertion of the electrode array without the need for an invasive mastoidectomy. Potential drill positioning errors must be accounted for to predict the effectiveness and safety of the procedure. The drilling accuracy of a system used for this procedure was evaluated in bone surrogate material under a range of clinically relevant parameters. Additional experiments were performed to isolate the error at various points along the path to better understand why deflections occur. An experimental setup to precisely position the drill press over a target was used. Custom bone surrogate test blocks were manufactured to resemble the mastoid region of the temporal bone. The drilling error was measured by creating divots in plastic sheets before and after drilling and using a microscope to localize the divots. The drilling error was within the tolerance needed to avoid vital structures and ensure accurate placement of the electrode; however, some parameter sets yielded errors that may impact the effectiveness of the procedure when combined with other error sources. The error increases when the lateral stage of the path terminates in an air cell and when the guide bushings are positioned further from the skull surface. At contact points due to air cells along the trajectory, higher errors were found for impact angles of [Formula: see text] and higher as well as longer cantilevered drill lengths. The results of these experiments can be used to define more accurate and safe drill trajectories for this minimally invasive surgical procedure.

  5. Stereo depth distortions in teleoperation

    NASA Technical Reports Server (NTRS)

    Diner, Daniel B.; Vonsydow, Marika

    1988-01-01

    In teleoperation, a typical application of stereo vision is to view a work space located short distances (1 to 3m) in front of the cameras. The work presented here treats converged camera placement and studies the effects of intercamera distance, camera-to-object viewing distance, and focal length of the camera lenses on both stereo depth resolution and stereo depth distortion. While viewing the fronto-parallel plane 1.4 m in front of the cameras, depth errors are measured on the order of 2cm. A geometric analysis was made of the distortion of the fronto-parallel plane of divergence for stereo TV viewing. The results of the analysis were then verified experimentally. The objective was to determine the optimal camera configuration which gave high stereo depth resolution while minimizing stereo depth distortion. It is found that for converged cameras at a fixed camera-to-object viewing distance, larger intercamera distances allow higher depth resolutions, but cause greater depth distortions. Thus with larger intercamera distances, operators will make greater depth errors (because of the greater distortions), but will be more certain that they are not errors (because of the higher resolution).

  6. Optimize of shrink process with X-Y CD bias on hole pattern

    NASA Astrophysics Data System (ADS)

    Koike, Kyohei; Hara, Arisa; Natori, Sakurako; Yamauchi, Shohei; Yamato, Masatoshi; Oyama, Kenichi; Yaegashi, Hidetami

    2017-03-01

    Gridded design rules[1] is major process in configuring logic circuit used 193-immersion lithography. In the scaling of grid patterning, we can make 10nm order line and space pattern by using multiple patterning techniques such as self-aligned multiple patterning (SAMP) and litho-etch- litho-etch (LELE)[2][3][4] . On the other hand, Line cut process has some error parameters such as pattern defect, placement error, roughness and X-Y CD bias with the decreasing scale. We tried to cure hole pattern roughness to use additional process such as Line smoothing[5] . Each smoothing process showed different effect. As the result, CDx shrink amount is smaller than CDy without one additional process. In this paper, we will report the pattern controllability comparison of EUV and 193-immersion. And we will discuss optimum method about CD bias on hole pattern.

  7. A dynamic measure of controllability and observability for the placement of actuators and sensors on large space structures

    NASA Technical Reports Server (NTRS)

    Vandervelde, W. E.; Carignan, C. R.

    1982-01-01

    The degree of controllability of a large space structure is found by a four step procedure: (1) finding the minimum control energy for driving the system from a given initial state to the origin in the prescribed time; (2) finding the region of initial state which can be driven to the origin with constrained control energy and time using optimal control strategy; (3) scaling the axes so that a unit displacement in every direction is equally important to control; and (4) finding the linear measurement of the weighted "volume" of the ellipsoid in the equicontrol space. For observability, the error covariance must be reduced toward zero using measurements optimally, and the criterion must be standardized by the magnitude of tolerable errors. The results obtained using these methods are applied to the vibration modes of a free-free beam.

  8. Medication Review and Transitions of Care: A Case Report of a Decade-Old Medication Error.

    PubMed

    Comer, Rachel; Lizer, Mitsi

    2017-10-01

    A 69-year-old Caucasian male with a 25-year history of paranoid schizophrenia was brought to the emergency department because of violence toward the staff in his nursing facility. He was diagnosed with a urinary tract infection and was admitted to the behavioral health unit for medication stabilization. History included a five-year state psychiatric hospital admission and nursing facility placement. Because of poor cognitive function, the patient was unable to corroborate medication history, so the pharmacy student on rotation performed an in-depth chart review. The review revealed a transcription error in 2003 deleting amantadine 100 mg twice daily and adding amiodarone 100 mg twice daily. Subsequent hospitalization resulted in another transcription error increasing the amiodarone to 200 mg twice daily. All electrocardiograms conducted were negative for atrial fibrillation. Once detected, the consulted cardiologist discontinued the amiodarone, and the primary care provider was notified via letter and discharge papers. An admission four months later revealed that the nursing facility restarted the amiodarone. Amiodarone was discontinued and the facility was again notified. This case reviews how a 10-year-old medication error went undetected in the electronic medical records through numerous medication reconciliations, but was uncovered when a single comprehensive medication review was conducted.

  9. Cognitive Task Analysis: Bringing Olympic Athlete Style Training to Surgical Education.

    PubMed

    Wingfield, Laura R; Kulendran, Myutan; Chow, Andre; Nehme, Jean; Purkayastha, Sanjay

    2015-08-01

    Surgical training is changing and evolving as time, pressure, and legislative demands continue to mount on trainee surgeons. A paradigm change in the focus of training has resulted in experts examining the cognitive steps needed to perform complex and often highly pressurized surgical procedures. To provide an overview of the collective evidence on cognitive task analysis (CTA) as a surgical training method, and determine if CTA improves a surgeon's performance as measured by technical and nontechnical skills assessment, including precision, accuracy, and operative errors. A systematic literature review was performed. PubMed, Cochrane, and reference lists were analyzed for appropriate inclusion. A total of 595 surgical participants were identified through the literature review and a total of 13 articles were included. Of these articles, 6 studies focused on general surgery, 2 focused on practical procedures relevant to surgery (central venous catheterization placement), 2 studies focused on head and neck surgical procedures (cricothyroidotomy and percutaneous tracheostomy placement), 2 studies highlighted vascular procedures (endovascular aortic aneurysm repair and carotid artery stenting), and 1 detailed endovascular repair (abdominal aorta and thoracic aorta). Overall, 92.3% of studies showed that CTA improves surgical outcome parameters, including time, precision, accuracy, and error reduction in both simulated and real-world environments. CTA has been shown to be a more effective training tool when compared with traditional methods of surgical training. There is a need for the introduction of CTA into surgical curriculums as this can improve surgical skill and ultimately create better patient outcomes. © The Author(s) 2014.

  10. Experimental Evaluation of UWB Indoor Positioning for Sport Postures

    PubMed Central

    Defraye, Jense; Steendam, Heidi; Gerlo, Joeri; De Clercq, Dirk; De Poorter, Eli

    2018-01-01

    Radio frequency (RF)-based indoor positioning systems (IPSs) use wireless technologies (including Wi-Fi, Zigbee, Bluetooth, and ultra-wide band (UWB)) to estimate the location of persons in areas where no Global Positioning System (GPS) reception is available, for example in indoor stadiums or sports halls. Of the above-mentioned forms of radio frequency (RF) technology, UWB is considered one of the most accurate approaches because it can provide positioning estimates with centimeter-level accuracy. However, it is not yet known whether UWB can also offer such accurate position estimates during strenuous dynamic activities in which moves are characterized by fast changes in direction and velocity. To answer this question, this paper investigates the capabilities of UWB indoor localization systems for tracking athletes during their complex (and most of the time unpredictable) movements. To this end, we analyze the impact of on-body tag placement locations and human movement patterns on localization accuracy and communication reliability. Moreover, two localization algorithms (particle filter and Kalman filter) with different optimizations (bias removal, non-line-of-sight (NLoS) detection, and path determination) are implemented. It is shown that although the optimal choice of optimization depends on the type of movement patterns, some of the improvements can reduce the localization error by up to 31%. Overall, depending on the selected optimization and on-body tag placement, our algorithms show good results in terms of positioning accuracy, with average errors in position estimates of 20 cm. This makes UWB a suitable approach for tracking dynamic athletic activities. PMID:29315267

  11. The flash memory battle: How low can we go?

    NASA Astrophysics Data System (ADS)

    van Setten, Eelco; Wismans, Onno; Grim, Kees; Finders, Jo; Dusa, Mircea; Birkner, Robert; Richter, Rigo; Scherübl, Thomas

    2008-03-01

    With the introduction of the TWINSCAN XT:1900Gi the limit of the water based hyper-NA immersion lithography has been reached in terms of resolution. With a numerical aperture of 1.35 a single expose resolution of 36.5nm half pitch has been demonstrated. However the practical resolution limit in production will be closer to 40nm half pitch, without having to go to double patterning alike strategies. In the relentless Flash memory market the performance of the exposure tool is stretched to the limit for a competitive advantage and cost-effective product. In this paper we will present the results of an experimental study of the resolution limit of the NAND-Flash Memory Gate layer for a production-worthy process on the TWINSCAN XT:1900Gi. The entire gate layer will be qualified in terms of full wafer CD uniformity, aberration sensitivities for the different wordlines and feature-center placement errors for 38, 39, 40 and 43nm half pitch design rule. In this study we will also compare the performance of a binary intensity mask to a 6% attenuated phase shift mask and look at strategies to maximize Depth of Focus, and to desensitize the gate layer for lens aberrations and placement errors. The mask is one of the dominant contributors to the CD uniformity budget of the flash gate layer. Therefore the wafer measurements are compared to aerial image measurements of the mask using AIMSTM 45-193i to separate the mask contribution from the scanner contribution to the final imaging performance.

  12. Unicompartmental knee arthroplasties: robot vs. patient specific instrumentation.

    PubMed

    Jaffry, Zahra; Masjedi, Milad; Clarke, Susannah; Harris, Simon; Karia, Monil; Andrews, Barry; Cobb, Justin

    2014-03-01

    The technical reliability demonstrated by semi active robots in implant placement could render unicompartmental knee arthroplasties (UKAs) more favourable than they are currently. The relatively untested method using patient specific instrumentation (PSI), however, has the potential to match the accuracy produced by robots but without the barriers that have prevented them from being used more widely in clinical practice, namely operative time. Therefore this study took a step towards comparing the accuracy and time taken between the two technologies. Thirty-six UKAs were carried out on identical knee models, 12 with the Sculptor, 12 with PSI and 12 conventionally under timed conditions. Implant placement in these knees was then judged against that in a pre-operative plan. Tibial implant orientations and femoral implant positions and orientations were significantly more accurate in the PSI group with mean errors of 6°, 2 mm and 4° respectively, than the conventional group which had means of 9°, 4 mm and 10°. There was no significant difference between the robot and PSI generally except in tibial implant orientation (mean robotic error 3°) and tibial implant position did not vary significantly across all three groups. It was also found that use of PSI and conventional methods took half the time taken by the robot (p<0.001). With further development, PSI can match and possibly surpass the accuracy of the robot, as it does with the conventional method, and achieve planned surgery in less time. This work sets the foundation for clinical trials involving PSI. Copyright © 2013 Elsevier B.V. All rights reserved.

  13. Inactivation of foodborne microorganisms using engineered water nanostructures (EWNS).

    PubMed

    Pyrgiotakis, Georgios; Vasanthakumar, Archana; Gao, Ya; Eleftheriadou, Mary; Toledo, Eduardo; DeAraujo, Alice; McDevitt, James; Han, Taewon; Mainelis, Gediminas; Mitchell, Ralph; Demokritou, Philip

    2015-03-17

    Foodborne diseases caused by the consumption of food contaminated with pathogenic microorganisms or their toxins have very serious economic and public health consequences. Here, we explored the effectiveness of a recently developed intervention method for inactivation of microorganisms on fresh produce, and food production surfaces. This method utilizes Engineered Water Nanostructures (EWNS) produced by electrospraying of water vapor. EWNS possess unique properties; they are 25 nm in diameter, remain airborne in indoor conditions for hours, contain Reactive Oxygen Species (ROS) and have very strong surface charge (on average 10 e/structure). Here, their efficacy in inactivating representative foodborne bacteria such as Escherichia coli, Salmonella enterica, and Listeria innocua, on stainless steel surfaces and on organic tomatoes, was assessed. The inactivation was facilitated using two different exposure approaches in order to optimize the delivery of EWNS to bacteria: (1) EWNS were delivered on the surfaces by diffusion and (2) a "draw through" Electrostatic Precipitator Exposure System (EPES) was developed and characterized for EWNS delivery to surfaces. Using the diffusion approach and an EWNS concentration of 24,000 #/cm3, the bacterial concentrations on the surfaces were reduced, depending on the bacterium and the surface type, by values ranging between 0.7 to 1.8 logs. Using the EPES approach and for an aerosol concentration of 50,000 #/cm3 at 90 min of exposure, results show a 1.4 log reduction for E. coli on organic tomato surfaces, as compared to the control (same conditions in regards to temperature and Relative Humidity). Furthermore, for L. innocua, the dose-response relationship was demonstrated and found to be a 0.7 and 1.2 logs removal at 12,000 and 23,000 #/cm3, respectively. The results presented here indicate that this novel, chemical-free, and environmentally friendly intervention method holds potential for development and application in the food industry, as a "green" alternative to existing disinfection methods.

  14. Laparogastroscopy and Esophageal Stenosis.

    PubMed

    Sabău, Alexandru-Dan; Hassan, Noor; Smarandache, Cătălin Gabriel; Miheţiu, Alin; Ţîţu, Ștefan; Sabău, Dan

    2018-01-01

    An original technique using laparoscopic instruments in a gastric endocavitary work chamber with potential for esophagus, stomach and D1 vizualisation. The main purpose of laparagastroscopy is to improve the quality of life of the patient disabling by the esophageal tumor. This method has several advantages: providing physiological feeding, harvesting materials for histopathological examination, solving eso-tracheal fistulas concurrently with the proposed operation and hemostatic role through compression, low energy and plastic consumption, rapid socio-economic reintegration, mental psychological care of the patient. Patients and Methods: The paper deals with 162 cases with different tumors of the esophagus, patients with different grades of esophageal stenosis, different stages of esophageal neoplasm. Both the patients with eso-tracheal fistulas and those with gastro- or jejunostoma were included. Results: From 162 cases, 33 cases (20%) with cervical esophageal neoplasm, 66 (41%) cases with thoracic esophageal neoplasm and 63 (39%) cases with abdominal esophageal neoplasm. The histopathological type is 37% adenocarcinomas and 63% squamous carcinomas. From total number of cases, 87 (54%) had no metastasis, and 75 (46%) had secondary determinations. The most frequent localization of metastasis was pulmonary, followed by liver (Fig. 1) and bone. The analysis of this intervention has shown that complications have been much lower both in terms of their numerical value and their severity, a longer survival time with a much higher satisfaction index is ensured. Esophageal endoprosthesis (EPE) through laparagastroscopic approach should be a a reserve procedure instead of a disabling gastrostomy or jejunostomy. EPE is an extremely effective procedure specially by keeping the physiology of food bowl. The approach is minimally invasive with minimal attack on the body with significant plastic and aesthetic reductions. This procedure allows the prosthesis to be viewed both during and after stenting to check its correct position. This method increases the survival time by keeping a relatively normal regimen. Celsius.

  15. Accuracy of image-guided surgical navigation using near infrared (NIR) optical tracking

    NASA Astrophysics Data System (ADS)

    Jakubovic, Raphael; Farooq, Hamza; Alarcon, Joseph; Yang, Victor X. D.

    2015-03-01

    Spinal surgery is particularly challenging for surgeons, requiring a high level of expertise and precision without being able to see beyond the surface of the bone. Accurate insertion of pedicle screws is critical considering perforation of the pedicle can result in profound clinical consequences including spinal cord, nerve root, arterial injury, neurological deficits, chronic pain, and/or failed back syndrome. Various navigation systems have been designed to guide pedicle screw fixation. Computed tomography (CT)-based image guided navigation systems increase the accuracy of screw placement allowing for 3- dimensional visualization of the spinal anatomy. Current localization techniques require extensive preparation and introduce spatial deviations. Use of near infrared (NIR) optical tracking allows for realtime navigation of the surgery by utilizing spectral domain multiplexing of light, greatly enhancing the surgeon's situation awareness in the operating room. While the incidence of pedicle screw perforation and complications have been significantly reduced with the introduction of modern navigational technologies, some error exists. Several parameters have been suggested including fiducial localization and registration error, target registration error, and angular deviation. However, many of these techniques quantify error using the pre-operative CT and an intra-operative screenshot without assessing the true screw trajectory. In this study we quantified in-vivo error by comparing the true screw trajectory to the intra-operative trajectory. Pre- and post- operative CT as well as intra-operative screenshots were obtained for a cohort of patients undergoing spinal surgery. We quantified entry point error and angular deviation in the axial and sagittal planes.

  16. 3D point cloud analysis of structured light registration in computer-assisted navigation in spinal surgeries

    NASA Astrophysics Data System (ADS)

    Gupta, Shaurya; Guha, Daipayan; Jakubovic, Raphael; Yang, Victor X. D.

    2017-02-01

    Computer-assisted navigation is used by surgeons in spine procedures to guide pedicle screws to improve placement accuracy and in some cases, to better visualize patient's underlying anatomy. Intraoperative registration is performed to establish a correlation between patient's anatomy and the pre/intra-operative image. Current algorithms rely on seeding points obtained directly from the exposed spinal surface to achieve clinically acceptable registration accuracy. Registration of these three dimensional surface point-clouds are prone to various systematic errors. The goal of this study was to evaluate the robustness of surgical navigation systems by looking at the relationship between the optical density of an acquired 3D point-cloud and the corresponding surgical navigation error. A retrospective review of a total of 48 registrations performed using an experimental structured light navigation system developed within our lab was conducted. For each registration, the number of points in the acquired point cloud was evaluated relative to whether the registration was acceptable, the corresponding system reported error and target registration error. It was demonstrated that the number of points in the point cloud neither correlates with the acceptance/rejection of a registration or the system reported error. However, a negative correlation was observed between the number of the points in the point-cloud and the corresponding sagittal angular error. Thus, system reported total registration points and accuracy are insufficient to gauge the accuracy of a navigation system and the operating surgeon must verify and validate registration based on anatomical landmarks prior to commencing surgery.

  17. Development of a surgical navigation system based on 3D Slicer for intraoperative implant placement surgery

    PubMed Central

    Chen, Xiaojun; Xu, Lu; Wang, Huixiang; Wang, Fang; Wang, Qiugen; Kikinis, Ron

    2017-01-01

    Implant placement has been widely used in various kinds of surgery. However, accurate intraoperative drilling performance is essential to avoid injury to adjacent structures. Although some commercially-available surgical navigation systems have been approved for clinical applications, these systems are expensive and the source code is not available to researchers. 3D Slicer is a free, open source software platform for the research community of computer-aided surgery. In this study, a loadable module based on Slicer has been developed and validated to support surgical navigation. This research module allows reliable calibration of the surgical drill, point-based registration and surface matching registration, so that the position and orientation of the surgical drill can be tracked and displayed on the computer screen in real time, aiming at reducing risks. In accuracy verification experiments, the mean target registration error (TRE) for point-based and surface-based registration were 0.31±0.06mm and 1.01±0.06mm respectively, which should meet clinical requirements. Both phantom and cadaver experiments demonstrated the feasibility of our surgical navigation software module. PMID:28109564

  18. Short-Term Distribution System State Forecast Based on Optimal Synchrophasor Sensor Placement and Extreme Learning Machine

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jiang, Huaiguang; Zhang, Yingchen

    This paper proposes an approach for distribution system state forecasting, which aims to provide an accurate and high speed state forecasting with an optimal synchrophasor sensor placement (OSSP) based state estimator and an extreme learning machine (ELM) based forecaster. Specifically, considering the sensor installation cost and measurement error, an OSSP algorithm is proposed to reduce the number of synchrophasor sensor and keep the whole distribution system numerically and topologically observable. Then, the weighted least square (WLS) based system state estimator is used to produce the training data for the proposed forecaster. Traditionally, the artificial neural network (ANN) and support vectormore » regression (SVR) are widely used in forecasting due to their nonlinear modeling capabilities. However, the ANN contains heavy computation load and the best parameters for SVR are difficult to obtain. In this paper, the ELM, which overcomes these drawbacks, is used to forecast the future system states with the historical system states. The proposed approach is effective and accurate based on the testing results.« less

  19. Examining recognition criterion rigidity during testing using a biased feedback technique: Evidence for adaptive criterion learning

    PubMed Central

    Han, Sanghoon; Dobbins, Ian G.

    2009-01-01

    Recognition models often assume that subjects use specific evidence values (decision criteria) to adaptively parse continuous memory evidence into response categories (e.g., “old” or “new”). Although explicit pre-test instructions influence criterion placement, these criteria appear extremely resistant to change once testing begins. We tested criterion sensitivity to local feedback using a novel, biased feedback technique designed to tacitly encourage certain errors by indicating they were correct choices. Experiment 1 demonstrated that fully correct feedback had little effect on criterion placement, whereas biased feedback during Experiments 2 and 3 yielded prominent, durable, and adaptive criterion shifts, with observers reporting they were unaware of the manipulation in Experiment 3. These data suggest recognition criteria can be easily modified during testing through a form of feedback learning that operates independent of stimulus characteristics and observer awareness of the nature of the manipulation. This mechanism may be fundamentally different than criterion shifts following explicit instructions and warnings, or shifts linked to manipulations of stimulus characteristics combined with feedback highlighting those manipulations. PMID:18604954

  20. Temporary arterial shunts to maintain limb perfusion after arterial injury: an animal study

    NASA Technical Reports Server (NTRS)

    Dawson, D. L.; Putnam, A. T.; Light, J. T.; Ihnat, D. M.; Kissinger, D. P.; Rasmussen, T. E.; Bradley, D. V. Jr

    1999-01-01

    BACKGROUND: Temporary shunt placement can quickly restore perfusion after extremity arterial injury. This study examined the adequacy of limb blood flow with shunt use, non-heparin-bonded shunt patency over prolonged periods, and the safety of this technique. METHODS: Common iliac arteries were divided and 4.0-mm Silastic Sundt shunts placed in 16 anesthetized pigs. Eight (group I) had shunts placed immediately; eight others (group II) were shunted after an hour of limb ischemia and hemorrhagic shock. Physiologic parameters and femoral artery blood flow in both hindlimbs were continuously monitored. Limb lactic acid generation, oxygen utilization, and hematologic and metabolic effects were serially evaluated for 24 hours. RESULTS: Shunts remained patent in 13 of 16 pigs. Shunts thrombosed in two group I animals because of technical errors, but functioned well after thrombectomy and repositioning. Patency could not be maintained in one animal that died from shock. Flow in group I shunted limbs was 57 (+/-11 SD) % of control. For group II animals in shock, shunted limb flow initially averaged 46 +/- 15% of control, but 4 hours after shunt placement, the mean limb blood flow was the same as in group I. Increased oxygen extraction compensated for the lower flow. Lactic acid production was not increased in comparison to control limbs. CONCLUSION: Shunts provided adequate flow in this model of extremity trauma. Correctly placed shunts stayed patent for 24 hours, without anticoagulation, if shunt placement followed resuscitation.

  1. Piezoelectrically Actuated Robotic System for MRI-Guided Prostate Percutaneous Therapy

    PubMed Central

    Su, Hao; Shang, Weijian; Cole, Gregory; Li, Gang; Harrington, Kevin; Camilo, Alexander; Tokuda, Junichi; Tempany, Clare M.; Hata, Nobuhiko; Fischer, Gregory S.

    2014-01-01

    This paper presents a fully-actuated robotic system for percutaneous prostate therapy under continuously acquired live magnetic resonance imaging (MRI) guidance. The system is composed of modular hardware and software to support the surgical workflow of intra-operative MRI-guided surgical procedures. We present the development of a 6-degree-of-freedom (DOF) needle placement robot for transperineal prostate interventions. The robot consists of a 3-DOF needle driver module and a 3-DOF Cartesian motion module. The needle driver provides needle cannula translation and rotation (2-DOF) and stylet translation (1-DOF). A custom robot controller consisting of multiple piezoelectric motor drivers provides precision closed-loop control of piezoelectric motors and enables simultaneous robot motion and MR imaging. The developed modular robot control interface software performs image-based registration, kinematics calculation, and exchanges robot commands and coordinates between the navigation software and the robot controller with a new implementation of the open network communication protocol OpenIGTLink. Comprehensive compatibility of the robot is evaluated inside a 3-Tesla MRI scanner using standard imaging sequences and the signal-to-noise ratio (SNR) loss is limited to 15%. The image deterioration due to the present and motion of robot demonstrates unobservable image interference. Twenty-five targeted needle placements inside gelatin phantoms utilizing an 18-gauge ceramic needle demonstrated 0.87 mm root mean square (RMS) error in 3D Euclidean distance based on MRI volume segmentation of the image-guided robotic needle placement procedure. PMID:26412962

  2. Prism adaptation and generalization during visually guided locomotor tasks.

    PubMed

    Alexander, M Scott; Flodin, Brent W G; Marigold, Daniel S

    2011-08-01

    The ability of individuals to adapt locomotion to constraints associated with the complex environments normally encountered in everyday life is paramount for survival. Here, we tested the ability of 24 healthy young adults to adapt to a rightward prism shift (∼11.3°) while either walking and stepping to targets (i.e., precision stepping task) or stepping over an obstacle (i.e., obstacle avoidance task). We subsequently tested for generalization to the other locomotor task. In the precision stepping task, we determined the lateral end-point error of foot placement from the targets. In the obstacle avoidance task, we determined toe clearance and lateral foot placement distance from the obstacle before and after stepping over the obstacle. We found large, rightward deviations in foot placement on initial exposure to prisms in both tasks. The majority of measures demonstrated adaptation over repeated trials, and adaptation rates were dependent mainly on the task. On removal of the prisms, we observed negative aftereffects for measures of both tasks. Additionally, we found a unilateral symmetric generalization pattern in that the left, but not the right, lower limb indicated generalization across the 2 locomotor tasks. These results indicate that the nervous system is capable of rapidly adapting to a visuomotor mismatch during visually demanding locomotor tasks and that the prism-induced adaptation can, at least partially, generalize across these tasks. The results also support the notion that the nervous system utilizes an internal model for the control of visually guided locomotion.

  3. Grain-scale Sr isotope heterogeneity in amphibolite (retrograded UHP eclogite, Dabie terrane): Implications for the origin and flow behavior of retrograde fluids during slab exhumation

    NASA Astrophysics Data System (ADS)

    Guo, Shun; Yang, Yueheng; Chen, Yi; Su, Bin; Gao, Yijie; Zhang, Lingmin; Liu, Jingbo; Mao, Qian

    2016-12-01

    To constrain the origin and flow behavior of amphibolite-facies retrograde fluids during slab exhumation, we investigate the textures, trace element contents, and in situ strontium (Sr) isotopic compositions (using LA-MC-ICP-MS) of multiple types of epidote and apatite in the UHP eclogite and amphibolites from the Hualiangting area (Dabie terrane, China). The UHP epidote porphyroblasts in the eclogite (Ep-E), which formed at 28-30 kbar and 660-720 °C, contain high amounts of Sr, Pb, Th, Ba, and light rare earth elements (LREEs) and have a narrow range of initial 87Sr/86Sr ratios (0.70431 ± 0.00012 to 0.70454 ± 0.00010). Two types of amphibolite-facies epidote were recognized in the amphibolites. The first type of epidote (Ep-AI) developed in all the amphibolites and has slightly lower trace element contents than Ep-E. The Ep-AI has a same initial 87Sr/86Sr ratio range as the Ep-E and represents the primary amphibolite-facies retrograde product that is associated with an internally buffered fluid at 8.0-10.3 kbar and 646-674 °C. The other type of epidote (Ep-AII) occurs as irregular fragments, veins/veinlets, or reaction rims on the Ep-AI in certain amphibolites. Elemental X-ray maps reveal the presence of Ep-AI relics in the Ep-AII domains (appearing as a patchy texture), which indicates that Ep-AII most likely formed by the partial replacement of the Ep-AI in the presence of an infiltrating fluid. The distinctly lower trace element contents of Ep-AII are ascribed to element scavenging by a mechanism of dissolution-transport-precipitation during replacement. The Ep-AII in an individual amphibolite exhibits large intra- and inter-grain variations in the initial 87Sr/86Sr ratios (0.70493 ± 0.00030 to 0.70907 ± 0.00022), which are between those of the Ep-AI and granitic gneisses (wall rock of the amphibolites, 0.7097-0.7108). These results verify that the infiltrating fluid was externally derived from granitic gneisses. The matrix apatite in the amphibolites has the same initial 87Sr/86Sr ratio range as the Ep-AI, indicating that the amphibolite-facies fluid involved in the apatite crystallization was also internally derived. We propose that at least two separate stages of fluids were accounted for the amphibolite-facies retrogression of the Hualiangting eclogite. The fluid responsible for the growth of most of the amphibolite minerals was locally derived and behaved in a pervasive manner, whereas the influx of gneiss-derived fluid was transient, episodic, and highly channelized with a longer transport distance (> 60 m). The disparate origins and flow behavior of these fluids significantly influence the water budget and element transfer in exhumed HP-UHP slabs. This study also indicates that examining grain-scale Sr isotopic variations provides key information regarding the isotopic (dis)equilibrium, fluid origins, and fluid-flow regimes in metamorphic or metasomatic rocks that form in subduction-zone environments.

  4. SU-E-T-484: In Vivo Dosimetry Tolerances in External Beam Fast Neutron Therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Young, L; Gopan, O

    Purpose: Optical stimulated luminescence (OSL) dosimetry with Landauer Al2O3:C nanodots was developed at our institution as a passive in vivo dosimetry (IVD) system for patients treated with fast neutron therapy. The purpose of this study was to establish clinically relevant tolerance limits for detecting treatment errors requiring further investigation. Methods: Tolerance levels were estimated by conducting a series of IVD expected dose calculations for square field sizes ranging between 2.8 and 28.8 cm. For each field size evaluated, doses were calculated for open and internal wedged fields with angles of 30°, 45°, or 60°. Theoretical errors were computed for variationsmore » of incorrect beam configurations. Dose errors, defined as the percent difference from the expected dose calculation, were measured with groups of three nanodots placed in a 30 x 30 cm solid water phantom, at beam isocenter (150 cm SAD, 1.7 cm Dmax). The tolerances were applied to IVD patient measurements. Results: The overall accuracy of the nanodot measurements is 2–3% for open fields. Measurement errors agreed with calculated errors to within 3%. Theoretical estimates of dosimetric errors showed that IVD measurements with OSL nanodots will detect the absence of an internal wedge or a wrong wedge angle. Incorrect nanodot placement on a wedged field is more likely to be caught if the offset is in the direction of the “toe” of the wedge where the dose difference in percentage is about 12%. Errors caused by an incorrect flattening filter size produced a 2% measurement error that is not detectable by IVD measurement alone. Conclusion: IVD with nanodots will detect treatment errors associated with the incorrect implementation of the internal wedge. The results of this study will streamline the physicists’ investigations in determining the root cause of an IVD reading that is out of normally accepted tolerances.« less

  5. Convergence of methods for coupling of microscopic and mesoscopic reaction-diffusion simulations

    NASA Astrophysics Data System (ADS)

    Flegg, Mark B.; Hellander, Stefan; Erban, Radek

    2015-05-01

    In this paper, three multiscale methods for coupling of mesoscopic (compartment-based) and microscopic (molecular-based) stochastic reaction-diffusion simulations are investigated. Two of the three methods that will be discussed in detail have been previously reported in the literature; the two-regime method (TRM) and the compartment-placement method (CPM). The third method that is introduced and analysed in this paper is called the ghost cell method (GCM), since it works by constructing a "ghost cell" in which molecules can disappear and jump into the compartment-based simulation. Presented is a comparison of sources of error. The convergent properties of this error are studied as the time step Δt (for updating the molecular-based part of the model) approaches zero. It is found that the error behaviour depends on another fundamental computational parameter h, the compartment size in the mesoscopic part of the model. Two important limiting cases, which appear in applications, are considered: Δt → 0 and h is fixed; Δt → 0 and h → 0 such that √{ Δt } / h is fixed. The error for previously developed approaches (the TRM and CPM) converges to zero only in the limiting case (ii), but not in case (i). It is shown that the error of the GCM converges in the limiting case (i). Thus the GCM is superior to previous coupling techniques if the mesoscopic description is much coarser than the microscopic part of the model.

  6. Digital Intraoral Imaging Re-Exposure Rates of Dental Students.

    PubMed

    Senior, Anthea; Winand, Curtis; Ganatra, Seema; Lai, Hollis; Alsulfyani, Noura; Pachêco-Pereira, Camila

    2018-01-01

    A guiding principle of radiation safety is ensuring that radiation dosage is as low as possible while yielding the necessary diagnostic information. Intraoral images taken with conventional dental film have a higher re-exposure rate when taken by dental students compared to experienced staff. The aim of this study was to examine the prevalence of and reasons for re-exposure of digital intraoral images taken by third- and fourth-year dental students in a dental school clinic. At one dental school in Canada, the total number of intraoral images taken by third- and fourth-year dental students, re-exposures, and error descriptions were extracted from patient clinical records for an eight-month period (September 2015 to April 2016). The data were categorized to distinguish between digital images taken with solid-state sensors or photostimulable phosphor plates (PSP). The results showed that 9,397 intraoral images were made, and 1,064 required re-exposure. The most common error requiring re-exposure for bitewing images was an error in placement of the receptor too far mesially or distally (29% for sensors and 18% for PSP). The most common error requiring re-exposure for periapical images was inadequate capture of the periapical area (37% for sensors and 6% for PSP). A retake rate of 11% was calculated, and the common technique errors causing image deficiencies were identified. Educational intervention can now be specifically designed to reduce the retake rate and radiation dose for future patients.

  7. Reduction in pediatric identification band errors: a quality collaborative.

    PubMed

    Phillips, Shannon Connor; Saysana, Michele; Worley, Sarah; Hain, Paul D

    2012-06-01

    Accurate and consistent placement of a patient identification (ID) band is used in health care to reduce errors associated with patient misidentification. Multiple safety organizations have devoted time and energy to improving patient ID, but no multicenter improvement collaboratives have shown scalability of previously successful interventions. We hoped to reduce by half the pediatric patient ID band error rate, defined as absent, illegible, or inaccurate ID band, across a quality improvement learning collaborative of hospitals in 1 year. On the basis of a previously successful single-site intervention, we conducted a self-selected 6-site collaborative to reduce ID band errors in heterogeneous pediatric hospital settings. The collaborative had 3 phases: preparatory work and employee survey of current practice and barriers, data collection (ID band failure rate), and intervention driven by data and collaborative learning to accelerate change. The collaborative audited 11377 patients for ID band errors between September 2009 and September 2010. The ID band failure rate decreased from 17% to 4.1% (77% relative reduction). Interventions including education of frontline staff regarding correct ID bands as a safety strategy; a change to softer ID bands, including "luggage tag" type ID bands for some patients; and partnering with families and patients through education were applied at all institutions. Over 13 months, a collaborative of pediatric institutions significantly reduced the ID band failure rate. This quality improvement learning collaborative demonstrates that safety improvements tested in a single institution can be disseminated to improve quality of care across large populations of children.

  8. A modern control theory based algorithm for control of the NASA/JPL 70-meter antenna axis servos

    NASA Technical Reports Server (NTRS)

    Hill, R. E.

    1987-01-01

    A digital computer-based state variable controller was designed and applied to the 70-m antenna axis servos. The general equations and structure of the algorithm and provisions for alternate position error feedback modes to accommodate intertarget slew, encoder referenced tracking, and precision tracking modes are descibed. Development of the discrete time domain control model and computation of estimator and control gain parameters based on closed loop pole placement criteria are discussed. The new algorithm was successfully implemented and tested in the 70-m antenna at Deep Space Network station 63 in Spain.

  9. Strategic marketing, part 2: the 4 P's of marketing.

    PubMed

    Lexa, Frank James; Berlin, Jonathan

    2006-04-01

    Marketing and branding are critical business functions that are often ignored or misapplied in the health care sector. Radiology professionals are facing unprecedented competition, turf battles, and other pressures. One tool that can help in meeting this onslaught is to improve your marketing efforts. Some of the most expensive mistakes in marketing (medical and otherwise) are caused by not paying attention to the basics. These "rookie" errors can be avoided by a careful review of the 4 key principles of introductory marketing: product, price, placement, and promotion. This article reviews these concepts as they relate to medical marketing.

  10. Executable assertions and flight software

    NASA Technical Reports Server (NTRS)

    Mahmood, A.; Andrews, D. M.; Mccluskey, E. J.

    1984-01-01

    Executable assertions are used to test flight control software. The techniques used for testing flight software; however, are different from the techniques used to test other kinds of software. This is because of the redundant nature of flight software. An experimental setup for testing flight software using executable assertions is described. Techniques for writing and using executable assertions to test flight software are presented. The error detection capability of assertions is studied and many examples of assertions are given. The issues of placement and complexity of assertions and the language features to support efficient use of assertions are discussed.

  11. Adjustable Parameter-Based Distributed Fault Estimation Observer Design for Multiagent Systems With Directed Graphs.

    PubMed

    Zhang, Ke; Jiang, Bin; Shi, Peng

    2017-02-01

    In this paper, a novel adjustable parameter (AP)-based distributed fault estimation observer (DFEO) is proposed for multiagent systems (MASs) with the directed communication topology. First, a relative output estimation error is defined based on the communication topology of MASs. Then a DFEO with AP is constructed with the purpose of improving the accuracy of fault estimation. Based on H ∞ and H 2 with pole placement, multiconstrained design is given to calculate the gain of DFEO. Finally, simulation results are presented to illustrate the feasibility and effectiveness of the proposed DFEO design with AP.

  12. Modified tension band wiring of medial malleolar ankle fractures.

    PubMed

    Georgiadis, G M; White, D B

    1995-02-01

    Twenty-two displaced medial malleolar ankle fractures that were treated surgically using the modified tension band method of Cleak and Dawson were retrospectively reviewed at an average follow-up of 25 months. The technique involves the use of a screw to anchor a figure-of-eight wire. There were no malreductions and all fractures healed. Problems with the technique included technical errors with hardware placement, medial ankle pain, and asymptomatic wire migration. Despite this, modified tension band wiring remains an acceptable method for fixation of selected displaced medial malleolar fractures. It is especially suited for small fracture fragments and osteoporotic bone.

  13. Visual difference metric for realistic image synthesis

    NASA Astrophysics Data System (ADS)

    Bolin, Mark R.; Meyer, Gary W.

    1999-05-01

    An accurate and efficient model of human perception has been developed to control the placement of sample in a realistic image synthesis algorithm. Previous sampling techniques have sought to spread the error equally across the image plane. However, this approach neglects the fact that the renderings are intended to be displayed for a human observer. The human visual system has a varying sensitivity to error that is based upon the viewing context. This means that equivalent optical discrepancies can be very obvious in one situation and imperceptible in another. It is ultimately the perceptibility of this error that governs image quality and should be used as the basis of a sampling algorithm. This paper focuses on a simplified version of the Lubin Visual Discrimination Metric (VDM) that was developed for insertion into an image synthesis algorithm. The sampling VDM makes use of a Haar wavelet basis for the cortical transform and a less severe spatial pooling operation. The model was extended for color including the effects of chromatic aberration. Comparisons are made between the execution time and visual difference map for the original Lubin and simplified visual difference metrics. Results for the realistic image synthesis algorithm are also presented.

  14. [MODIS Investigation

    NASA Technical Reports Server (NTRS)

    Abbott, Mark R.

    1996-01-01

    Our first activity is based on delivery of code to Bob Evans (University of Miami) for integration and eventual delivery to the MODIS Science Data Support Team. As we noted in our previous semi-annual report, coding required the development and analysis of an end-to-end model of fluorescence line height (FLH) errors and sensitivity. This model is described in a paper in press in Remote Sensing of the Environment. Once the code was delivered to Miami, we continue to use this error analysis to evaluate proposed changes in MODIS sensor specifications and performance. Simply evaluating such changes on a band by band basis may obscure the true impacts of changes in sensor performance that are manifested in the complete algorithm. This is especially true with FLH that is sensitive to band placement and width. The error model will be used by Howard Gordon (Miami) to evaluate the effects of absorbing aerosols on the FLH algorithm performance. Presently, FLH relies only on simple corrections for atmospheric effects (viewing geometry, Rayleigh scattering) without correcting for aerosols. Our analysis suggests that aerosols should have a small impact relative to changes in the quantum yield of fluorescence in phytoplankton. However, the effect of absorbing aerosol is a new process and will be evaluated by Gordon.

  15. A multi-level rapid prototyping drill guide template reduces the perforation risk of pedicle screw placement in the lumbar and sacral spine.

    PubMed

    Merc, Matjaz; Drstvensek, Igor; Vogrin, Matjaz; Brajlih, Tomaz; Recnik, Gregor

    2013-07-01

    The method of free-hand pedicle screw placement is generally safe although it carries potential risks. For this reason, several highly accurate computer-assisted systems were developed and are currently on the market. However, these devices have certain disadvantages. We have developed a method of pedicle screw placement in the lumbar and sacral region using a multi-level drill guide template, created with the rapid prototyping technology and have validated it in a clinical study. The aim of the study was to manufacture and evaluate the accuracy of a multi-level drill guide template for lumbar and first sacral pedicle screw placement and to compare it with the free-hand technique under fluoroscopy supervision. In 2011 and 2012, a randomized clinical trial was performed on 20 patients. 54 screws were implanted in the trial group using templates and 54 in the control group using the fluoroscopy-supervised free-hand technique. Furthermore, applicability for the first sacral level was tested. Preoperative CT-scans were taken and templates were designed using the selective laser sintering method. Postoperative evaluation and statistical analysis of pedicle violation, displacement, screw length and deviation were performed for both groups. The incidence of cortex perforation was significantly reduced in the template group; likewise, the deviation and displacement level of screws in the sagittal plane. In both groups there was no significantly important difference in deviation and displacement level in the transversal plane as not in pedicle screw length. The results for the first sacral level resembled the main investigated group. The method significantly lowers the incidence of cortex perforation and is therefore potentially applicable in clinical practice, especially in some selected cases. The applied method, however, carries a potential for errors during manufacturing and practical usage and therefore still requires further improvements.

  16. Catheter placement for lysis of spontaneous intracerebral hematomas: is a navigated stylet better than pointer-guided frameless stereotaxy for intrahematomal catheter positioning?

    PubMed

    Malinova, Vesna; Stockhammer, Florian; Atangana, Etienne Ndzie; Mielke, Dorothee; Rohde, Veit

    2014-06-01

    The optimal management of spontaneous intracerebral hemorrhage (ICH), especially if deep-seated, remains a matter of discussion. Lysis of the blood clot applying recombinant tissue-type plasminogen activator (rtPA) by an intrahematomal catheter is a minimally invasive treatment option, currently being under investigation in a randomized trial. The center position of the catheter in the hematoma is believed to be crucial for an optimal clot lysis. To achieve this objective, frame-based stereotaxy and frameless stereotaxy with guidance of an articulated arm were used. Recently, a preregistered stylet for direct navigation, alleviating the need of guidance, became available. In this study, we evaluated the relative error (RE) describing the deviation of the catheter from the ideal center position in the clot and compared the accuracy of catheter placement using frameless stereotaxy or the novel preregistered stylet. The intrahematomal catheter position was evaluated in three dimensions in 89 patients with spontaneous supratentorial ICH. Frameless stereotaxy with guidance of an articulated arm was performed in 50 patients. The preregistered stylet was used in 39 patients. The catheter position was evaluated using a RE calculating the distance perpendicular to the center of the catheter in relation to the hematoma's diameter. The mean hematoma volume was 51.4 ml. Forty-four out of 89 hematomas were deep-seated. Intraventricular blood was found in 59 patients. The RE of the catheter position was lower in the stylet group in comparison to the frameless stereotaxy group (mean 0.57 vs. 0.90; p = 0.0018). There was no difference between deep-seated and lobar hematomas with regard to the accuracy of catheter placement (p = 0.62). The RE is a robust measure for describing intrahematomal catheter position. The preregistered stylet facilitates a satisfactory catheter placement and is a viable alternative to frameless stereotaxy and guidance with the articulated arm.

  17. Robotic Assistance for Ultrasound-Guided Prostate Brachytherapy

    PubMed Central

    Fichtinger, Gabor; Fiene, Jonathan P.; Kennedy, Christopher W.; Kronreif, Gernot; Iordachita, Iulian; Song, Danny Y.; Burdette, Everette C.; Kazanzides, Peter

    2016-01-01

    We present a robotically assisted prostate brachytherapy system and test results in training phantoms and Phase-I clinical trials. The system consists of a transrectal ultrasound (TRUS) and a spatially co-registered robot, fully integrated with an FDA-approved commercial treatment planning system. The salient feature of the system is a small parallel robot affixed to the mounting posts of the template. The robot replaces the template interchangeably, using the same coordinate system. Established clinical hardware, workflow and calibration remain intact. In all phantom experiments, we recorded the first insertion attempt without adjustment. All clinically relevant locations in the prostate were reached. Non-parallel needle trajectories were achieved. The pre-insertion transverse and rotational errors (measured with a Polaris optical tracker relative to the template’s coordinate frame) were 0.25mm (STD=0.17mm) and 0.75° (STD=0.37°). In phantoms, needle tip placement errors measured in TRUS were 1.04mm (STD=0.50mm). A Phase-I clinical feasibility and safety trial has been successfully completed with the system. We encountered needle tip positioning errors of a magnitude greater than 4mm in only 2 out of 179 robotically guided needles, in contrast to manual template guidance where errors of this magnitude are much more common. Further clinical trials are necessary to determine whether the apparent benefits of the robotic assistant will lead to improvements in clinical efficacy and outcomes. PMID:18650122

  18. Rover mast calibration, exact camera pointing, and camara handoff for visual target tracking

    NASA Technical Reports Server (NTRS)

    Kim, Won S.; Ansar, Adnan I.; Steele, Robert D.

    2005-01-01

    This paper presents three technical elements that we have developed to improve the accuracy of the visual target tracking for single-sol approach-and-instrument placement in future Mars rover missions. An accurate, straightforward method of rover mast calibration is achieved by using a total station, a camera calibration target, and four prism targets mounted on the rover. The method was applied to Rocky8 rover mast calibration and yielded a 1.1-pixel rms residual error. Camera pointing requires inverse kinematic solutions for mast pan and tilt angles such that the target image appears right at the center of the camera image. Two issues were raised. Mast camera frames are in general not parallel to the masthead base frame. Further, the optical axis of the camera model in general does not pass through the center of the image. Despite these issues, we managed to derive non-iterative closed-form exact solutions, which were verified with Matlab routines. Actual camera pointing experiments aver 50 random target image paints yielded less than 1.3-pixel rms pointing error. Finally, a purely geometric method for camera handoff using stereo views of the target has been developed. Experimental test runs show less than 2.5 pixels error on high-resolution Navcam for Pancam-to-Navcam handoff, and less than 4 pixels error on lower-resolution Hazcam for Navcam-to-Hazcam handoff.

  19. Scheduling policies of intelligent sensors and sensor/actuators in flexible structures

    NASA Astrophysics Data System (ADS)

    Demetriou, Michael A.; Potami, Raffaele

    2006-03-01

    In this note, we revisit the problem of actuator/sensor placement in large civil infrastructures and flexible space structures within the context of spatial robustness. The positioning of these devices becomes more important in systems employing wireless sensor and actuator networks (WSAN) for improved control performance and for rapid failure detection. The ability of the sensing and actuating devices to possess the property of spatial robustness results in reduced control energy and therefore the spatial distribution of disturbances is integrated into the location optimization measures. In our studies, the structure under consideration is a flexible plate clamped at all sides. First, we consider the case of sensor placement and the optimization scheme attempts to produce those locations that minimize the effects of the spatial distribution of disturbances on the state estimation error; thus the sensor locations produce state estimators with minimized disturbance-to-error transfer function norms. A two-stage optimization procedure is employed whereby one first considers the open loop system and the spatial distribution of disturbances is found that produces the maximal effects on the entire open loop state. Once this "worst" spatial distribution of disturbances is found, the optimization scheme subsequently finds the locations that produce state estimators with minimum transfer function norms. In the second part, we consider the collocated actuator/sensor pairs and the optimization scheme produces those locations that result in compensators with the smallest norms of the disturbance-to-state transfer functions. Going a step further, an intelligent control scheme is presented which, at each time interval, activates a subset of the actuator/sensor pairs in order provide robustness against spatiotemporally moving disturbances and minimize power consumption by keeping some sensor/actuators in sleep mode.

  20. Optimal distance of multi-plane sensor in three-dimensional electrical impedance tomography.

    PubMed

    Hao, Zhenhua; Yue, Shihong; Sun, Benyuan; Wang, Huaxiang

    2017-12-01

    Electrical impedance tomography (EIT) is a visual imaging technique for obtaining the conductivity and permittivity distributions in the domain of interest. As an advanced technique, EIT has the potential to be a valuable tool for continuously bedside monitoring of pulmonary function. The EIT applications in any three-dimensional (3 D) field are very limited to the 3 D effects, i.e. the distribution of electric field spreads far beyond the electrode plane. The 3 D effects can result in measurement errors and image distortion. An important way to overcome the 3 D effect is to use the multiple groups of sensors. The aim of this paper is to find the best space resolution of EIT image over various electrode planes and select an optimal plane spacing in a 3 D EIT sensor, and provide guidance for 3 D EIT electrodes placement in monitoring lung function. In simulation and experiment, several typical conductivity distribution models, such as one rod (central, midway and edge), two rods and three rods, are set at different plane spacings between the two electrode planes. A Tikhonov regularization algorithm is utilized for reconstructing the images; the relative error and the correlation coefficient are utilized for evaluating the image quality. Based on numerical simulation and experimental results, the image performance at different spacing conditions is evaluated. The results demonstrate that there exists an optimal plane spacing between the two electrode planes for 3 D EIT sensor. And then the selection of the optimal plane spacing between the electrode planes is suggested for the electrodes placement of multi-plane EIT sensor.

  1. Tutoring Trainees to Suture: An Alternative Method for Learning How to Suture and a Way to Compensate for a Lack of Suturing Cases.

    PubMed

    Wongkietkachorn, Apinut; Rhunsiri, Peera; Boonyawong, Pangpoom; Lawanprasert, Attaporn; Tantiphlachiva, Kasaya

    2016-01-01

    Tutoring in suturing was developed to compensate for a shortage of suturing cases. The objective of this study was to compare ideal suturing score (ISS; 9 points), suturing time (min:sec), and suture placement error (mm) between medical students completing the suturing tutoring program and medical students attending ordinary medical school training program. Participants consisted of 2 groups of medical students who had never performed suturing. The study group had the role of suturing tutor to teach interested high school students. The control group consisted of volunteers from the ordinary medical school program. Skills measurement was performed by having students from both the groups perform 3 vertical mattress sutures on a model. The study group was tested at weeks 1, 9, and 10 to assess improvement. Both the groups were tested at week 10 to compare final learning outcome. There were 41 and 40 participants in the study group and the control group, respectively. ISS was significantly improved in the study group from week 1-week 10 (7.0 ± 1.3 vs. 8.2 ± 0.9, p = 0.01). At week 10, the study group had a higher mean ISS than the control group (8.2 ± 0.9 vs. 7.8 ± 1.1, p = 0.68). Mean suturing time and mean placement error were also lower in the study group at the end of suturing training (5:1 ± 1:0 vs. 5:2 ± 1:2, p = 0.13; 7.4 ± 7.4 vs. 8.0 ± 10.8, p = 0.44). Tutoring trainees to suture can improve a student's ability to learn how to suture. Copyright © 2016 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.

  2. 1.5 T augmented reality navigated interventional MRI: paravertebral sympathetic plexus injections

    PubMed Central

    Marker, David R.; U-Thainual, Paweena; Ungi, Tamas; Flammang, Aaron J.; Fichtinger, Gabor; Iordachita, Iulian I.; Carrino, John A.; Fritz, Jan

    2017-01-01

    PURPOSE The high contrast resolution and absent ionizing radiation of interventional magnetic resonance imaging (MRI) can be advantageous for paravertebral sympathetic nerve plexus injections. We assessed the feasibility and technical performance of MRI-guided paravertebral sympathetic injections utilizing augmented reality navigation and 1.5 T MRI scanner. METHODS A total of 23 bilateral injections of the thoracic (8/23, 35%), lumbar (8/23, 35%), and hypogastric (7/23, 30%) paravertebral sympathetic plexus were prospectively planned in twelve human cadavers using a 1.5 Tesla (T) MRI scanner and augmented reality navigation system. MRI-conditional needles were used. Gadolinium-DTPA-enhanced saline was injected. Outcome variables included the number of control magnetic resonance images, target error of the needle tip, punctures of critical nontarget structures, distribution of the injected fluid, and procedure length. RESULTS Augmented-reality navigated MRI guidance at 1.5 T provided detailed anatomical visualization for successful targeting of the paravertebral space, needle placement, and perineural paravertebral injections in 46 of 46 targets (100%). A mean of 2 images (range, 1–5 images) were required to control needle placement. Changes of the needle trajectory occurred in 9 of 46 targets (20%) and changes of needle advancement occurred in 6 of 46 targets (13%), which were statistically not related to spinal regions (P = 0.728 and P = 0.86, respectively) and cadaver sizes (P = 0.893 and P = 0.859, respectively). The mean error of the needle tip was 3.9±1.7 mm. There were no punctures of critical nontarget structures. The mean procedure length was 33±12 min. CONCLUSION 1.5 T augmented reality-navigated interventional MRI can provide accurate imaging guidance for perineural injections of the thoracic, lumbar, and hypogastric sympathetic plexus. PMID:28420598

  3. First clinical use of the EchoTrack guidance approach for radiofrequency ablation of thyroid gland nodules.

    PubMed

    Franz, Alfred Michael; Seitel, Alexander; Bopp, Nasrin; Erbelding, Christian; Cheray, Dominique; Delorme, Stefan; Grünwald, Frank; Korkusuz, Hüdayi; Maier-Hein, Lena

    2017-06-01

    Percutaneous radiofrequency ablation (RFA) of thyroid nodules is an alternative to surgical resection that offers the benefits of minimal scars for the patient, lower complication rates, and shorter treatment times. Ultrasound (US) is the preferred modality for guiding these procedures. The needle is usually kept within the US scanning plane to ensure needle visibility. However, this restricts flexibility in both transducer and needle movement and renders the procedure difficult, especially for inexperienced users. Existing navigation solutions often involve electromagnetic (EM) tracking, which requires placement of an external field generator (FG) in close proximity of the intervention site in order to avoid distortion of the EM field. This complicates the clinical workflow as placing the FG while ensuring that it neither restricts the physician's workspace nor affects tracking accuracy is awkward and time-consuming. The EchoTrack concept overcomes these issues by combining the US probe and the EM FG in one modality, simultaneously providing both real-time US and tracking data without requiring the placement of an external FG for tracking. We propose a system and workflow to use EchoTrack for RFA of thyroid nodules. According to our results, the overall error of the EchoTrack system resulting from errors related to tracking and calibration is below 2 mm. Navigated thyroid RFA with the proposed concept is clinically feasible. Motion of internal critical structures relative to external markers can be up to several millimeters in extreme cases. The EchoTrack concept with its simple setup, flexibility, improved needle visualization, and additional guidance information has high potential to be clinically used for thyroid RFA.

  4. 1.5 T augmented reality navigated interventional MRI: paravertebral sympathetic plexus injections.

    PubMed

    Marker, David R; U Thainual, Paweena; Ungi, Tamas; Flammang, Aaron J; Fichtinger, Gabor; Iordachita, Iulian I; Carrino, John A; Fritz, Jan

    2017-01-01

    The high contrast resolution and absent ionizing radiation of interventional magnetic resonance imaging (MRI) can be advantageous for paravertebral sympathetic nerve plexus injections. We assessed the feasibility and technical performance of MRI-guided paravertebral sympathetic injections utilizing augmented reality navigation and 1.5 T MRI scanner. A total of 23 bilateral injections of the thoracic (8/23, 35%), lumbar (8/23, 35%), and hypogastric (7/23, 30%) paravertebral sympathetic plexus were prospectively planned in twelve human cadavers using a 1.5 Tesla (T) MRI scanner and augmented reality navigation system. MRI-conditional needles were used. Gadolinium-DTPA-enhanced saline was injected. Outcome variables included the number of control magnetic resonance images, target error of the needle tip, punctures of critical nontarget structures, distribution of the injected fluid, and procedure length. Augmented-reality navigated MRI guidance at 1.5 T provided detailed anatomical visualization for successful targeting of the paravertebral space, needle placement, and perineural paravertebral injections in 46 of 46 targets (100%). A mean of 2 images (range, 1-5 images) were required to control needle placement. Changes of the needle trajectory occurred in 9 of 46 targets (20%) and changes of needle advancement occurred in 6 of 46 targets (13%), which were statistically not related to spinal regions (P = 0.728 and P = 0.86, respectively) and cadaver sizes (P = 0.893 and P = 0.859, respectively). The mean error of the needle tip was 3.9±1.7 mm. There were no punctures of critical nontarget structures. The mean procedure length was 33±12 min. 1.5 T augmented reality-navigated interventional MRI can provide accurate imaging guidance for perineural injections of the thoracic, lumbar, and hypogastric sympathetic plexus.

  5. Predicted osteotomy planes are accurate when using patient-specific instrumentation for total knee arthroplasty in cadavers: a descriptive analysis.

    PubMed

    Kievit, A J; Dobbe, J G G; Streekstra, G J; Blankevoort, L; Schafroth, M U

    2018-06-01

    Malalignment of implants is a major source of failure during total knee arthroplasty. To achieve more accurate 3D planning and execution of the osteotomy cuts during surgery, the Signature (Biomet, Warsaw) patient-specific instrumentation (PSI) was used to produce pin guides for the positioning of the osteotomy blocks by means of computer-aided manufacture based on CT scan images. The research question of this study is: what is the transfer accuracy of osteotomy planes predicted by the Signature PSI system for preoperative 3D planning and intraoperative block-guided pin placement to perform total knee arthroplasty procedures? The transfer accuracy achieved by using the Signature PSI system was evaluated by comparing the osteotomy planes predicted preoperatively with the osteotomy planes seen intraoperatively in human cadaveric legs. Outcomes were measured in terms of translational and rotational errors (varus, valgus, flexion, extension and axial rotation) for both tibia and femur osteotomies. Average translational errors between the osteotomy planes predicted using the Signature system and the actual osteotomy planes achieved was 0.8 mm (± 0.5 mm) for the tibia and 0.7 mm (± 4.0 mm) for the femur. Average rotational errors in relation to predicted and achieved osteotomy planes were 0.1° (± 1.2°) of varus and 0.4° (± 1.7°) of anterior slope (extension) for the tibia, and 2.8° (± 2.0°) of varus and 0.9° (± 2.7°) of flexion and 1.4° (± 2.2°) of external rotation for the femur. The similarity between osteotomy planes predicted using the Signature system and osteotomy planes actually achieved was excellent for the tibia although some discrepancies were seen for the femur. The use of 3D system techniques in TKA surgery can provide accurate intraoperative guidance, especially for patients with deformed bone, tailored to individual patients and ensure better placement of the implant.

  6. Evaluation of a new electronic preoperative reference marker for toric intraocular lens implantation by two different methods of analysis: Adobe Photoshop versus iTrace.

    PubMed

    Farooqui, Javed Hussain; Sharma, Mansi; Koul, Archana; Dutta, Ranjan; Shroff, Noshir Minoo

    2017-01-01

    The aim of this study is to compare two different methods of analysis of preoperative reference marking for toric intraocular lens (IOL) after marking with an electronic marker. Cataract and IOL Implantation Service, Shroff Eye Centre, New Delhi, India. Fifty-two eyes of thirty patients planned for toric IOL implantation were included in the study. All patients had preoperative marking performed with an electronic preoperative two-step toric IOL reference marker (ASICO AE-2929). Reference marks were placed at 3-and 9-o'clock positions. Marks were analyzed with two systems. First, slit-lamp photographs taken and analyzed using Adobe Photoshop (version 7.0). Second, Tracey iTrace Visual Function Analyzer (version 5.1.1) was used for capturing corneal topograph examination and position of marks noted. Amount of alignment error was calculated. Mean absolute rotation error was 2.38 ± 1.78° by Photoshop and 2.87 ± 2.03° by iTrace which was not statistically significant ( P = 0.215). Nearly 72.7% of eyes by Photoshop and 61.4% by iTrace had rotation error ≤3° ( P = 0.359); and 90.9% of eyes by Photoshop and 81.8% by iTrace had rotation error ≤5° ( P = 0.344). No significant difference in absolute amount of rotation between eyes when analyzed by either method. Difference in reference mark positions when analyzed by two systems suggests the presence of varying cyclotorsion at different points of time. Both analysis methods showed an approximately 3° of alignment error, which could contribute to 10% loss of astigmatic correction of toric IOL. This can be further compounded by intra-operative marking errors and final placement of IOL in the bag.

  7. A Preliminary ZEUS Lightning Location Error Analysis Using a Modified Retrieval Theory

    NASA Technical Reports Server (NTRS)

    Elander, Valjean; Koshak, William; Phanord, Dieudonne

    2004-01-01

    The ZEUS long-range VLF arrival time difference lightning detection network now covers both Europe and Africa, and there are plans for further expansion into the western hemisphere. In order to fully optimize and assess ZEUS lightning location retrieval errors and to determine the best placement of future receivers expected to be added to the network, a software package is being developed jointly between the NASA Marshall Space Flight Center (MSFC) and the University of Nevada Las Vegas (UNLV). The software package, called the ZEUS Error Analysis for Lightning (ZEAL), will be used to obtain global scale lightning location retrieval error maps using both a Monte Carlo approach and chi-squared curvature matrix theory. At the core of ZEAL will be an implementation of an Iterative Oblate (IO) lightning location retrieval method recently developed at MSFC. The IO method will be appropriately modified to account for variable wave propagation speed, and the new retrieval results will be compared with the current ZEUS retrieval algorithm to assess potential improvements. In this preliminary ZEAL work effort, we defined 5000 source locations evenly distributed across the Earth. We then used the existing (as well as potential future ZEUS sites) to simulate arrival time data between source and ZEUS site. A total of 100 sources were considered at each of the 5000 locations, and timing errors were selected from a normal distribution having a mean of 0 seconds and a standard deviation of 20 microseconds. This simulated "noisy" dataset was analyzed using the IO algorithm to estimate source locations. The exact locations were compared with the retrieved locations, and the results are summarized via several color-coded "error maps."

  8. Quantitative vs. subjective portal verification using digital portal images.

    PubMed

    Bissett, R; Leszczynski, K; Loose, S; Boyko, S; Dunscombe, P

    1996-01-15

    Off-line, computer-aided prescription (simulator) and treatment (portal) image registration using chamfer matching has been implemented on PC based viewing station. The purposes of this study were (a) to evaluate the performance of interactive anatomy and field edge extraction and subsequent registration, and (b) to compare observer's perceptions of field accuracy with measured discrepancies following anatomical registration. Prescription-treatment image pairs for 48 different patients were examined in this study. Digital prescription images were produced with the aid of a television camera and a digital frame grabber, while the treatment images were obtained directly from an on-line portal imaging system. To facilitate perception of low contrast anatomical detail, on-line portal images were enhanced with selective adaptive histogram equalization prior to extraction of anatomical edges. Following interactive extraction of anatomical and field border information by an experienced observer, the identified anatomy was registered using chamfer matching. The degree of conformity between the prescription and treatment fields was quantified using several parameters, which included relative prescription field coverage and overcoverage, as well as the translational and rotational displacements as measured by chamfer matching applied to the boundaries of the two fields. These quantitative measures were compared with subjective evaluations made by four radiation oncologists. All the images in this series that included a range of the most commonly seen treatment sites were registered and the conformity parameters were found. The mean treatment/prescription field coverage and overcoverage were approximately 95 and 7%, respectively before registration. The mean translational displacement in the transverse and cranio-caudal directions were 2.9 and 3.4 mm, respectively. The mean rotational displacement was approximately 2 degrees. For all four oncologists, the portals classified as unacceptable, in terms of the field placement, exhibited significantly higher (p < 0.03) translational errors in the transverse direction. The field coverages were significantly lower (p < 0.05) and the translational errors in the cranio-caudal direction were significantly higher (p < 0.05) for the portals rated as unacceptable by two of the oncologists. From the parameters that were used to quantify the degree of conformity between the prescription and treatment fields, the translational error in the transverse direction correlated best with the oncologists' assessments on the field placement. Field coverage and translational error in the cranio-caudal direction correlated well with assessments of only two out of the four participating oncologists. This can be explained by the fact that for the majority of treatment sites included in the study the positioning of field borders was more critical for the transverse direction. A conclusion for the design of future quantitative and automated on-line portal verification systems is that they will have to model different perceived significances of different types of localization errors intrinsic to oncologist evaluation of portal images.

  9. The new Licox combined brain tissue oxygen and brain temperature monitor: assessment of in vitro accuracy and clinical experience in severe traumatic brain injury.

    PubMed

    Stewart, Campbell; Haitsma, Iain; Zador, Zsolt; Hemphill, J Claude; Morabito, Diane; Manley, Geoffrey; Rosenthal, Guy

    2008-12-01

    Monitoring of brain tissue oxygen tension is increasingly being used to monitor patients after severe traumatic brain injury and to guide therapies aimed at maintaining brain tissue oxygen tension above threshold levels. The new Licox PMO combined oxygen and temperature catheter (Integra LifeSciences, Plainsboro, NJ) combines measurements of oxygen tension and temperature in a single probe inserted through a bolt mechanism. In this study, we sought to evaluate the accuracy of the new Licox PMO probe under controlled laboratory conditions and to assess the accuracy of oxygen tension and temperature measurements and the new automated card calibration system. We also describe our clinical experience with the Licox PMO probe. Oxygen tension was measured in a 2-chambered apparatus at different oxygen tensions and temperatures. The new card calibration system was compared with a manually calibrated system. Rates of hematoma, infection, and dislodgement in our clinical experience were recorded. The new Licox PMO probe accurately measures oxygen tension over a wide range of oxygen concentrations and physiological temperatures, but it does have a small tendency to underestimate oxygen tension (mean error, -3.8 +/- 3.5%) that is more pronounced between the temperatures of 33 and 39 degrees C. The thermistor of the PMO probe also has a tendency to underestimate temperature when compared with a resistance thermometer (mean error, -0.67 +/- 0.22 degrees C). The card calibration system was also found to introduce some variability in measurements of oxygen tension when compared with a manually calibrated system. Clinical experience with the new probe indicates good placement within the white matter using the improved bolt system and low rates of hematoma (2.9%), infection (0%), and dislodgement (5.9%). The new Licox PMO probe is accurate but has a small, consistent tendency to under-read oxygen tension that is more pronounced at higher temperatures. The probe tends to under-read temperature by 0.5 to 0.8 degrees C across temperatures, suggesting that caution should be used when brain temperature is measured with the Licox PMO probe and used to guide temperature-directed treatment strategies. The Licox PMO probe improves upon previous models in allowing consistent and accurate placement in the white matter and obviating the need for placement of 2 separate probes to measure oxygen tension and temperature.

  10. In vivo reproducibility of robotic probe placement for an integrated US-CT image-guided radiation therapy system

    NASA Astrophysics Data System (ADS)

    Lediju Bell, Muyinatu A.; Sen, H. Tutkun; Iordachita, Iulian; Kazanzides, Peter; Wong, John

    2014-03-01

    Radiation therapy is used to treat cancer by delivering high-dose radiation to a pre-defined target volume. Ultrasound (US) has the potential to provide real-time, image-guidance of radiation therapy to identify when a target moves outside of the treatment volume (e.g. due to breathing), but the associated probe-induced tissue deformation causes local anatomical deviations from the treatment plan. If the US probe is placed to achieve similar tissue deformations in the CT images required for treatment planning, its presence causes streak artifacts that will interfere with treatment planning calculations. To overcome these challenges, we propose robot-assisted placement of a real ultrasound probe, followed by probe removal and replacement with a geometrically-identical, CT-compatible model probe. This work is the first to investigate in vivo deformation reproducibility with the proposed approach. A dog's prostate, liver, and pancreas were each implanted with three 2.38-mm spherical metallic markers, and the US probe was placed to visualize the implanted markers in each organ. The real and model probes were automatically removed and returned to the same position (i.e. position control), and CT images were acquired with each probe placement. The model probe was also removed and returned with the same normal force measured with the real US probe (i.e. force control). Marker positions in CT images were analyzed to determine reproducibility, and a corollary reproducibility study was performed on ex vivo tissue. In vivo results indicate that tissue deformations with the real probe were repeatable under position control for the prostate, liver, and pancreas, with median 3D reproducibility of 0.3 mm, 0.3 mm, and 1.6 mm, respectively, compared to 0.6 mm for the ex vivo tissue. For the prostate, the mean 3D tissue displacement errors between the real and model probes were 0.2 mm under position control and 0.6 mm under force control, which are both within acceptable radiotherapy treatment margins. The 3D displacement errors between the real and model probes were less acceptable for the liver and pancreas (4.1-6.1 mm), and force control maintained poorer reproducibility than position control.

  11. Methods for calculating the electrode position Jacobian for impedance imaging.

    PubMed

    Boyle, A; Crabb, M G; Jehl, M; Lionheart, W R B; Adler, A

    2017-03-01

    Electrical impedance tomography (EIT) or electrical resistivity tomography (ERT) current and measure voltages at the boundary of a domain through electrodes. The movement or incorrect placement of electrodes may lead to modelling errors that result in significant reconstructed image artifacts. These errors may be accounted for by allowing for electrode position estimates in the model. Movement may be reconstructed through a first-order approximation, the electrode position Jacobian. A reconstruction that incorporates electrode position estimates and conductivity can significantly reduce image artifacts. Conversely, if electrode position is ignored it can be difficult to distinguish true conductivity changes from reconstruction artifacts which may increase the risk of a flawed interpretation. In this work, we aim to determine the fastest, most accurate approach for estimating the electrode position Jacobian. Four methods of calculating the electrode position Jacobian were evaluated on a homogeneous halfspace. Results show that Fréchet derivative and rank-one update methods are competitive in computational efficiency but achieve different solutions for certain values of contact impedance and mesh density.

  12. Automated structure refinement of macromolecular assemblies from cryo-EM maps using Rosetta.

    PubMed

    Wang, Ray Yu-Ruei; Song, Yifan; Barad, Benjamin A; Cheng, Yifan; Fraser, James S; DiMaio, Frank

    2016-09-26

    Cryo-EM has revealed the structures of many challenging yet exciting macromolecular assemblies at near-atomic resolution (3-4.5Å), providing biological phenomena with molecular descriptions. However, at these resolutions, accurately positioning individual atoms remains challenging and error-prone. Manually refining thousands of amino acids - typical in a macromolecular assembly - is tedious and time-consuming. We present an automated method that can improve the atomic details in models that are manually built in near-atomic-resolution cryo-EM maps. Applying the method to three systems recently solved by cryo-EM, we are able to improve model geometry while maintaining the fit-to-density. Backbone placement errors are automatically detected and corrected, and the refinement shows a large radius of convergence. The results demonstrate that the method is amenable to structures with symmetry, of very large size, and containing RNA as well as covalently bound ligands. The method should streamline the cryo-EM structure determination process, providing accurate and unbiased atomic structure interpretation of such maps.

  13. Extensibility in local sensor based planning for hyper-redundant manipulators (robot snakes)

    NASA Technical Reports Server (NTRS)

    Choset, Howie; Burdick, Joel

    1994-01-01

    Partial Shape Modification (PSM) is a local sensor feedback method used for hyper-redundant robot manipulators, in which the redundancy is very large or infinite such as that of a robot snake. This aspect of redundancy enables local obstacle avoidance and end-effector placement in real time. Due to the large number of joints or actuators in a hyper-redundant manipulator, small displacement errors of such easily accumulate to large errors in the position of the tip relative to the base. The accuracy could be improved by a local sensor based planning method in which sensors are distributed along the length of the hyper-redundant robot. This paper extends the local sensor based planning strategy beyond the limitations of the fixed length of such a manipulator when its joint limits are met. This is achieved with an algorithm where the length of the deforming part of the robot is variable. Thus , the robot's local avoidance of obstacles is improved through the enhancement of its extensibility.

  14. An IMU-to-Body Alignment Method Applied to Human Gait Analysis.

    PubMed

    Vargas-Valencia, Laura Susana; Elias, Arlindo; Rocon, Eduardo; Bastos-Filho, Teodiano; Frizera, Anselmo

    2016-12-10

    This paper presents a novel calibration procedure as a simple, yet powerful, method to place and align inertial sensors with body segments. The calibration can be easily replicated without the need of any additional tools. The proposed method is validated in three different applications: a computer mathematical simulation; a simplified joint composed of two semi-spheres interconnected by a universal goniometer; and a real gait test with five able-bodied subjects. Simulation results demonstrate that, after the calibration method is applied, the joint angles are correctly measured independently of previous sensor placement on the joint, thus validating the proposed procedure. In the cases of a simplified joint and a real gait test with human volunteers, the method also performs correctly, although secondary plane errors appear when compared with the simulation results. We believe that such errors are caused by limitations of the current inertial measurement unit (IMU) technology and fusion algorithms. In conclusion, the presented calibration procedure is an interesting option to solve the alignment problem when using IMUs for gait analysis.

  15. Active vibration control of a single-stage spur gearbox

    NASA Astrophysics Data System (ADS)

    Dogruer, C. U.; Pirsoltan, Abbas K.

    2017-02-01

    The dynamic transmission error between driving and driven gears of a gear mechanism with torsional mode is induced by periodic time-varying mesh stiffness. In this study, to minimize the adverse effect of this time-varying mesh stiffness, a nonlinear controller which adjusts the torque acting on the driving gear is proposed. The basic approach is to modulate the input torque such that it compensates the periodic change in mesh stiffness. It is assumed that gears are assembled with high precision and gearbox is analyzed by a finite element software to calculate the mesh stiffness curve. Thus, change in the mesh stiffness, which is inherently nonlinear, can be predicted and canceled by a feed-forward loop. Then, remaining linear dynamics is controlled by pole placement techniques. Under these premises, it is claimed that any acceleration and velocity profile of the input shaft can be tracked accurately. Thereby, dynamic transmission error is kept to a minimum possible value and a spur gearbox, which does not emit much noise and vibration, is designed.

  16. A digital volumetric tomography (DVT) study in the mandibular molar region for miniscrew placement during mixed dentition

    PubMed Central

    Bhattad, Mayur S.; Baliga, Sudhindra; Vibhute, Pavan

    2015-01-01

    OBJECTIVE: To assess bone thickness for miniscrew placement in the mandible during mixed dentition by using digital volumetric tomograph (DVT). MATERIAL AND METHODS: A total of 15 healthy patients aged 8-10 years old, with early exfoliated mandibular second deciduous molar, were included. DVT images of one quadrant of the mandible were obtained using Kodak extraoral imaging systems and analyzed by Kodak dental imaging software. The error of the method (EM) was calculated using Dahlberg's formula. Mean and standard deviation were calculated at 6 and 8 mm from the cementoenamel junction (CEJ).Paired t-test was used to analyze the measurements. RESULTS: Buccal cortical bone thickness, mesiodistal width and buccolingual bone depth at 6 mm were found to be 1.73 + 0.41, 2.15 + 0.49 and 13.18 + 1.22 mm, respectively; while at 8 mm measurements were 2.42 + 0.34, 2.48 + 0.33 and 13.65 + 1.25 mm, respectively. EM for buccal cortical bone thickness, mesiodistal width and buccolingual bone depth was 0.58, 0.40 and 0.48, respectively. The difference in measurement at 6 and 8 mm for buccal cortical plate thickness (P < 0.05) and buccolingual bone thickness (P < 0.05) was found to be significant, whereas for mesiodistal width it was insignificant (P > 0.05). CONCLUSION: Bone thickness measurement has shown promising evidence for safe placement of miniscrews in the mandible during mixed dentition. The use of miniscrew is the best alternative, even in younger patients. PMID:25992988

  17. The Role of Echocardiography in the Optimization of Cardiac Resynchronization Therapy: Current Evidence and Future Perspectives.

    PubMed

    Spartalis, Michael; Tzatzaki, Eleni; Spartalis, Eleftherios; Damaskos, Christos; Athanasiou, Antonios; Livanis, Efthimios; Voudris, Vassilis

    2017-01-01

    Cardiac resynchronization therapy (CRT) has become a mainstay in the management of heart failure. Up to one-third of patients who received resynchronization devices do not experience the full benefits of CRT. The clinical factors influencing the likelihood to respond to the therapy are wide QRS complex, left bundle branch block, female gender, non-ischaemic cardiomyopathy (highest responders), male gender, ischaemic cardiomyopathy (moderate responders) and narrow QRS complex, non-left bundle branch block (lowest, non-responders). This review provides a conceptual description of the role of echocardiography in the optimization of CRT. A literature survey was performed using PubMed database search to gather information regarding CRT and echocardiography. A total of 70 studies met selection criteria for inclusion in the review. Echocardiography helps in the initial selection of the patients with dyssynchrony, which will benefit the most from optimal biventricular pacing and provides a guide to left ventricular (LV) lead placement during implantation. Different echocardiographic parameters have shown promise and can offer the possibility of patient selection, response prediction, lead placement optimization strategies and optimization of device configurations. LV ejection fraction along with specific electrocardiographic criteria remains the cornerstone of CRT patient selection. Echocardiography is a non-invasive, cost-effective, highly reproducible method with certain limitations and accuracy that is affected by measurement errors. Echocardiography can assist with the identification of the appropriate electromechanical substrate of CRT response and LV lead placement. The targeted approach can improve the haemodynamic response, as also the patient-specific parameters estimation.

  18. The Role of Echocardiography in the Optimization of Cardiac Resynchronization Therapy: Current Evidence and Future Perspectives

    PubMed Central

    Spartalis, Michael; Tzatzaki, Eleni; Spartalis, Eleftherios; Damaskos, Christos; Athanasiou, Antonios; Livanis, Efthimios; Voudris, Vassilis

    2017-01-01

    Background: Cardiac resynchronization therapy (CRT) has become a mainstay in the management of heart failure. Up to one-third of patients who received resynchronization devices do not experience the full benefits of CRT. The clinical factors influencing the likelihood to respond to the therapy are wide QRS complex, left bundle branch block, female gender, non-ischaemic cardiomyopathy (highest responders), male gender, ischaemic cardiomyopathy (moderate responders) and narrow QRS complex, non-left bundle branch block (lowest, non-responders). Objective: This review provides a conceptual description of the role of echocardiography in the optimization of CRT. Method: A literature survey was performed using PubMed database search to gather information regarding CRT and echocardiography. Results: A total of 70 studies met selection criteria for inclusion in the review. Echocardiography helps in the initial selection of the patients with dyssynchrony, which will benefit the most from optimal biventricular pacing and provides a guide to left ventricular (LV) lead placement during implantation. Different echocardiographic parameters have shown promise and can offer the possibility of patient selection, response prediction, lead placement optimization strategies and optimization of device configurations. Conclusion: LV ejection fraction along with specific electrocardiographic criteria remains the cornerstone of CRT patient selection. Echocardiography is a non-invasive, cost-effective, highly reproducible method with certain limitations and accuracy that is affected by measurement errors. Echocardiography can assist with the identification of the appropriate electromechanical substrate of CRT response and LV lead placement. The targeted approach can improve the haemodynamic response, as also the patient-specific parameters estimation. PMID:29387277

  19. Design for Natural Breast Augmentation: The ICE Principle.

    PubMed

    Mallucci, Patrick; Branford, Olivier Alexandre

    2016-06-01

    The authors' published studies have helped define breast beauty in outlining key parameters that contribute to breast attractiveness. The "ICE" principle puts design into practice. It is a simplified formula for inframammary fold incision planning as part of the process for determining implant selection and placement to reproduce the 45:55 ratio previously described as fundamental to natural breast appearance. The formula is as follows: implant dimensions (I) - capacity of the breast (C) = excess tissue required (E). The aim of this study was to test the accuracy of the ICE principle for producing consistent natural beautiful results in breast augmentation. A prospective analysis of 50 consecutive women undergoing primary breast augmentation by means of an inframammary fold incision with anatomical or round implants was performed. The ICE principle was applied to all cases to determine implant selection, placement, and incision position. Changes in parameters between preoperative and postoperative digital clinical photographs were analyzed. The mean upper pole-to-lower pole ratio changed from 52:48 preoperatively to 45:55 postoperatively (p < 0.0001). Mean nipple angulation was also statistically significantly elevated from 11 degrees to 19 degrees skyward (p ≤ 0.0005). Accuracy of incision placement in the fold was 99.7 percent on the right and 99.6 percent on the left, with a standard error of only 0.2 percent. There was a reduction in variability for all key parameters. The authors have shown using the simple ICE principle for surgical planning in breast augmentation that attractive natural breasts may be achieved consistently and with precision. Therapeutic, IV.

  20. Complications in hair restoration.

    PubMed

    Lam, Samuel M

    2013-11-01

    Hair restoration requires a high level of specialized skill on the part of both the surgeon and the assistant team. Recipient-site problems can manifest from either surgeon or assistant error. The surgeon can create an unnatural hairline due to lack of knowledge of natural hair-loss patterns or badly executed recipient sites. He must also be cognizant of how hairs naturally are angled on the scalp to re-create a pattern that appears natural when making recipient sites. Assistants can also greatly contribute to the success or failure of surgery in their task of graft dissection and graft placement. Copyright © 2013 Elsevier Inc. All rights reserved.

  1. The use of 3D scanning for sporting applications

    NASA Astrophysics Data System (ADS)

    Friel, Kevin; Ajjimaporn, Pann; Straub, Jeremy; Kerlin, Scott

    2015-05-01

    This paper describes the process and research that went into creating a set of 3D models to characterize a golf swing. The purpose of this work is to illustrate how a 3D scanner could be used for assessing athlete performance in sporting applications. In this case, introductory work has been performed to show how the scanner could be used to show the errors a golfer made in a swing. Multiple factors must be taken into account when assessing golfers' swings including the position and movement of the golfer's hands, arms, and foot placement as well as the position of the club head and shaft of the golf club.

  2. Graphene as discharge layer for electron beam lithography on insulating substrate

    NASA Astrophysics Data System (ADS)

    Liu, Junku; Li, Qunqing; Ren, Mengxin; Zhang, Lihui; Chen, Mo; Fan, Shoushan

    2013-09-01

    Charging of insulating substrates is a common problem during Electron Beam lithography (EBL), which deflects the beam and distorts the pattern. A homogeneous, electrically conductive, and transparent graphene layer is used as a discharge layer for EBL processes on insulating substrates. The EBL resolution is improved compared with the metal discharge layer. Dense arrays of holes with diameters of 50 nm and gratings with line/space of 50/30 nm are obtained on quartz substrate. The pattern placement errors and proximity effect are suppressed over a large area and high quality complex nanostructures are fabricated using graphene as a conductive layer.

  3. Eye care in the elderly.

    PubMed

    Green, Catherine; Goodfellow, Jonathan; Kubie, Jessica

    2014-07-01

    Eye disease and visual impairment are common in the elderly and are associated with social and functional decline, the need to access community support services, depression, falls, nursing home placement and increased mortality. To provide guidance for general practitioners in the detection and recommended management of the most important eye conditions in the elderly in Australia: refractive error, cataract, diabetic retinopathy, age-related macular degeneration and glaucoma. Timely detection and treatment of eye disease can greatly reduce its morbidity. Elderly patients should be encouraged to undergo eye testing every 2 years. Health professionals, including general practitioners, optometrists and ophthalmologists should work collaboratively to ensure patients have access to appropriate disease detection and treatment.

  4. Clinical Performance of Pedo Jacket Crowns in Maxillary Anterior Primary Teeth.

    PubMed

    Castro, Aimee; Badr, Sherine B Y; El-Badrawy, Wafa; Kulkarni, Gajanan

    2016-09-15

    To assess the clinical performance of Pedo Jacket crowns for restoration of carious primary anterior teeth. A total of 129 carious primary incisors and canines of 48 children younger than 71 months of age- were restored with Pedo Jacket crowns and resin-modified glass ionomer cementation. They were assessed for: ease of use; presence of recurrent decay; wear; partial or complete loss of the crown; color stability; gingival health; and overall clinical success over a 12-month follow-up. The patient's behavior at the restorative appointment during crown placement was also assessed. An overall clinical success of 89.5 percent of the teeth in 87.3 percent of the children was seen one year later. The crowns were easy to use, even in uncooperative children. The color stability, wear, plaque accumulation, and gingival health were acceptable. Discoloration, wear, or complete loss of the crown were found in 13.1 percent, 5.4 percent, and 7.6 percent of children, respectively. Although not statistically significant, failures were associated with poor patient cooperation at the time of crown placement, poor oral hygiene, or operator error. Pedo Jacket crowns are a viable treatment alternative for carious maxillary primary anterior teeth.

  5. Morphological tricks and blessed genitalia: rectifying the family placement of Fijicolana tuberculata (Opiliones: Laniatores: Zalmoxidae).

    PubMed

    Pérez-González, Abel; Sharma, Prashant P; Proud, Daniel N

    2016-01-07

    The type specimens of Fijicolana tuberculata Roewer, 1963 were re-examined and the male genital morphology is illustrated and described for the first time. Despite the presence of several morphological features that are typical of Samoidae, such as the presence of scopulae on legs III and IV, genital morphology unambiguously indicates that this species belongs to the Zalmoxidae rather than to the Samoidae. Fijicolana Roewer, 1963 is newly synonymized with Zalmoxis Sørensen, 1886. However, the newly implied combination is preoccupied by Z. tuberculatus Goodnight & Goodnight, 1948 thus the replacement name Zalmoxis roeweri nom. nov. is proposed to avoid secondary homonymy. The definition of Z. roeweri nom. nov. is amended, and the morphology of this species is compared with other representatives of Zalmoxidae and Samoidae. We conclude that the presence of scopulae alone is not a sufficiently diagnostic characteristic for Samoidae and, therefore, correctly placing taxa into families within Samooidea + Zalmoxoidea requires additional morphological evidence (e.g. genital morphology). In light of this result, we point out that the "scopulated" Australasian samoids Badessania metatarsalis Roewer, 1949, Sawaiellus berlandi Roewer, 1949 and Parasamoa gressitti Goodnight & Goodnight, 1957 require re-examination in order to detect potential errors in their family placement.

  6. Needle Steering in Biological Tissue using Ultrasound-based Online Curvature Estimation

    PubMed Central

    Moreira, Pedro; Patil, Sachin; Alterovitz, Ron; Misra, Sarthak

    2014-01-01

    Percutaneous needle insertions are commonly performed for diagnostic and therapeutic purposes. Accurate placement of the needle tip is important to the success of many needle procedures. The current needle steering systems depend on needle-tissue-specific data, such as maximum curvature, that is unavailable prior to an interventional procedure. In this paper, we present a novel three-dimensional adaptive steering method for flexible bevel-tipped needles that is capable of performing accurate tip placement without previous knowledge about needle curvature. The method steers the needle by integrating duty-cycled needle steering, online curvature estimation, ultrasound-based needle tracking, and sampling-based motion planning. The needle curvature estimation is performed online and used to adapt the path and duty cycling. We evaluated the method using experiments in a homogenous gelatin phantom, a two-layer gelatin phantom, and a biological tissue phantom composed of a gelatin layer and in vitro chicken tissue. In all experiments, virtual obstacles and targets move in order to represent the disturbances that might occur due to tissue deformation and physiological processes. The average targeting error using our new adaptive method is 40% lower than using the conventional non-adaptive duty-cycled needle steering method. PMID:26229729

  7. Multi-modal imaging, model-based tracking, and mixed reality visualisation for orthopaedic surgery

    PubMed Central

    Fuerst, Bernhard; Tateno, Keisuke; Johnson, Alex; Fotouhi, Javad; Osgood, Greg; Tombari, Federico; Navab, Nassir

    2017-01-01

    Orthopaedic surgeons are still following the decades old workflow of using dozens of two-dimensional fluoroscopic images to drill through complex 3D structures, e.g. pelvis. This Letter presents a mixed reality support system, which incorporates multi-modal data fusion and model-based surgical tool tracking for creating a mixed reality environment supporting screw placement in orthopaedic surgery. A red–green–blue–depth camera is rigidly attached to a mobile C-arm and is calibrated to the cone-beam computed tomography (CBCT) imaging space via iterative closest point algorithm. This allows real-time automatic fusion of reconstructed surface and/or 3D point clouds and synthetic fluoroscopic images obtained through CBCT imaging. An adapted 3D model-based tracking algorithm with automatic tool segmentation allows for tracking of the surgical tools occluded by hand. This proposed interactive 3D mixed reality environment provides an intuitive understanding of the surgical site and supports surgeons in quickly localising the entry point and orienting the surgical tool during screw placement. The authors validate the augmentation by measuring target registration error and also evaluate the tracking accuracy in the presence of partial occlusion. PMID:29184659

  8. An Automated Method for High-Definition Transcranial Direct Current Stimulation Modeling*

    PubMed Central

    Huang, Yu; Su, Yuzhuo; Rorden, Christopher; Dmochowski, Jacek; Datta, Abhishek; Parra, Lucas C.

    2014-01-01

    Targeted transcranial stimulation with electric currents requires accurate models of the current flow from scalp electrodes to the human brain. Idiosyncratic anatomy of individual brains and heads leads to significant variability in such current flows across subjects, thus, necessitating accurate individualized head models. Here we report on an automated processing chain that computes current distributions in the head starting from a structural magnetic resonance image (MRI). The main purpose of automating this process is to reduce the substantial effort currently required for manual segmentation, electrode placement, and solving of finite element models. In doing so, several weeks of manual labor were reduced to no more than 4 hours of computation time and minimal user interaction, while current-flow results for the automated method deviated by less than 27.9% from the manual method. Key facilitating factors are the addition of three tissue types (skull, scalp and air) to a state-of-the-art automated segmentation process, morphological processing to correct small but important segmentation errors, and automated placement of small electrodes based on easily reproducible standard electrode configurations. We anticipate that such an automated processing will become an indispensable tool to individualize transcranial direct current stimulation (tDCS) therapy. PMID:23367144

  9. Double patterning from design enablement to verification

    NASA Astrophysics Data System (ADS)

    Abercrombie, David; Lacour, Pat; El-Sewefy, Omar; Volkov, Alex; Levine, Evgueni; Arb, Kellen; Reid, Chris; Li, Qiao; Ghosh, Pradiptya

    2011-11-01

    Litho-etch-litho-etch (LELE) is the double patterning (DP) technology of choice for 20 nm contact, via, and lower metal layers. We discuss the unique design and process characteristics of LELE DP, the challenges they present, and various solutions. ∘ We examine DP design methodologies, current DP conflict feedback mechanisms, and how they can help designers identify and resolve conflicts. ∘ In place and route (P&R), the placement engine must now be aware of the assumptions made during IP cell design, and use placement directives provide by the library designer. We examine the new effects DP introduces in detail routing, discuss how multiple choices of LELE and the cut allowances can lead to different solutions, and describe new capabilities required by detail routers and P&R engines. ∘ We discuss why LELE DP cuts and overlaps are critical to optical process correction (OPC), and how a hybrid mechanism of rule and model-based overlap generation can provide a fast and effective solution. ∘ With two litho-etch steps, mask misalignment and image rounding are now verification considerations. We present enhancements to the OPCVerify engine that check for pinching and bridging in the presence of DP overlay errors and acute angles.

  10. Precision instrument placement using a 4-DOF robot with integrated fiducials for minimally invasive interventions

    NASA Astrophysics Data System (ADS)

    Stenzel, Roland; Lin, Ralph; Cheng, Peng; Kronreif, Gernot; Kornfeld, Martin; Lindisch, David; Wood, Bradford J.; Viswanathan, Anand; Cleary, Kevin

    2007-03-01

    Minimally invasive procedures are increasingly attractive to patients and medical personnel because they can reduce operative trauma, recovery times, and overall costs. However, during these procedures, the physician has a very limited view of the interventional field and the exact position of surgical instruments. We present an image-guided platform for precision placement of surgical instruments based upon a small four degree-of-freedom robot (B-RobII; ARC Seibersdorf Research GmbH, Vienna, Austria). This platform includes a custom instrument guide with an integrated spiral fiducial pattern as the robot's end-effector, and it uses intra-operative computed tomography (CT) to register the robot to the patient directly before the intervention. The physician can then use a graphical user interface (GUI) to select a path for percutaneous access, and the robot will automatically align the instrument guide along this path. Potential anatomical targets include the liver, kidney, prostate, and spine. This paper describes the robotic platform, workflow, software, and algorithms used by the system. To demonstrate the algorithmic accuracy and suitability of the custom instrument guide, we also present results from experiments as well as estimates of the maximum error between target and instrument tip.

  11. Advanced overlay analysis through design based metrology

    NASA Astrophysics Data System (ADS)

    Ji, Sunkeun; Yoo, Gyun; Jo, Gyoyeon; Kang, Hyunwoo; Park, Minwoo; Kim, Jungchan; Park, Chanha; Yang, Hyunjo; Yim, Donggyu; Maruyama, Kotaro; Park, Byungjun; Yamamoto, Masahiro

    2015-03-01

    As design rule shrink, overlay has been critical factor for semiconductor manufacturing. However, the overlay error which is determined by a conventional measurement with an overlay mark based on IBO and DBO often does not represent the physical placement error in the cell area. The mismatch may arise from the size or pitch difference between the overlay mark and the cell pattern. Pattern distortion caused by etching or CMP also can be a source of the mismatch. In 2014, we have demonstrated that method of overlay measurement in the cell area by using DBM (Design Based Metrology) tool has more accurate overlay value than conventional method by using an overlay mark. We have verified the reproducibility by measuring repeatable patterns in the cell area, and also demonstrated the reliability by comparing with CD-SEM data. We have focused overlay mismatching between overlay mark and cell area until now, further more we have concerned with the cell area having different pattern density and etch loading. There appears a phenomenon which has different overlay values on the cells with diverse patterning environment. In this paper, the overlay error was investigated from cell edge to center. For this experiment, we have verified several critical layers in DRAM by using improved(Better resolution and speed) DBM tool, NGR3520.

  12. Global Warming Estimation from MSU: Correction for Drift and Calibration Errors

    NASA Technical Reports Server (NTRS)

    Prabhakara, C.; Iacovazzi, R., Jr.; Yoo, J.-M.; Einaudi, Franco (Technical Monitor)

    2000-01-01

    Microwave Sounding Unit (MSU) radiometer observations in Ch 2 (53.74 GHz), made in the nadir direction from sequential, sun-synchronous, polar-orbiting NOAA morning satellites (NOAA 6, 10 and 12 that have about 7am/7pm orbital geometry) and afternoon satellites (NOAA 7, 9, 11 and 14 that have about 2am/2pm orbital geometry) are analyzed in this study to derive global temperature trend from 1980 to 1998. In order to remove the discontinuities between the data of the successive satellites and to get a continuous time series, first we have used shortest possible time record of each satellite. In this way we get a preliminary estimate of the global temperature trend of 0.21 K/decade. However, this estimate is affected by systematic time-dependent errors. One such error is the instrument calibration error. This error can be inferred whenever there are overlapping measurements made by two satellites over an extended period of time. From the available successive satellite data we have taken the longest possible time record of each satellite to form the time series during the period 1980 to 1998 to this error. We find we can decrease the global temperature trend by about 0.07 K/decade. In addition there are systematic time dependent errors present in the data that are introduced by the drift in the satellite orbital geometry arises from the diurnal cycle in temperature which is the drift related change in the calibration of the MSU. In order to analyze the nature of these drift related errors the multi-satellite Ch 2 data set is partitioned into am and pm subsets to create two independent time series. The error can be assessed in the am and pm data of Ch 2 on land and can be eliminated. Observations made in the MSU Ch 1 (50.3 GHz) support this approach. The error is obvious only in the difference between the pm and am observations of Ch 2 over the ocean. We have followed two different paths to assess the impact of the errors on the global temperature trend. In one path the entire error is placed in the am data while in the other it is placed in the pm data. Global temperature trend is increased or decreased by about 0.03 K/decade depending upon this placement. Taking into account all random errors and systematic errors our analysis of MSU observations leads us to conclude that a conservative estimate of the global warming is 0. 11 (+-) 0.04 K/decade during 1980 to 1998.

  13. Optimum sensor placement for microphone arrays

    NASA Astrophysics Data System (ADS)

    Rabinkin, Daniel V.

    Microphone arrays can be used for high-quality sound pickup in reverberant and noisy environments. Sound capture using conventional single microphone methods suffers severe degradation under these conditions. The beamforming capabilities of microphone array systems allow highly directional sound capture, providing enhanced signal-to-noise ratio (SNR) when compared to single microphone performance. The overall performance of an array system is governed by its ability to locate and track sound sources and its ability to capture sound from desired spatial volumes. These abilities are strongly affected by the spatial placement of microphone sensors. A method is needed to optimize placement for a specified number of sensors in a given acoustical environment. The objective of the optimization is to obtain the greatest average system SNR for sound capture in the region of interest. A two-step sound source location method is presented. In the first step, time delay of arrival (TDOA) estimates for select microphone pairs are determined using a modified version of the Omologo-Svaizer cross-power spectrum phase expression. In the second step, the TDOA estimates are used in a least-mean-squares gradient descent search algorithm to obtain a location estimate. Statistics for TDOA estimate error as a function of microphone pair/sound source geometry and acoustic environment are gathered from a set of experiments. These statistics are used to model position estimation accuracy for a given array geometry. The effectiveness of sound source capture is also dependent on array geometry and the acoustical environment. Simple beamforming and time delay compensation (TDC) methods provide spatial selectivity but suffer performance degradation in reverberant environments. Matched filter array (MFA) processing can mitigate the effects of reverberation. The shape and gain advantage of the capture region for these techniques is described and shown to be highly influenced by the placement of array sensors. A procedure is developed to evaluate a given array configuration based on the above-mentioned metrics. Constrained placement optimizations are performed that maximize SNR for both TDC and MFA capture methods. Results are compared for various acoustic environments and various enclosure sizes. General guidelines are presented for placement strategy and bandwidth dependence, as they relate to reverberation levels, ambient noise, and enclosure geometry. An overall performance function is described based on these metrics. Performance of the microphone array system is also constrained by the design limitations of the supporting hardware. Two newly developed hardware architectures are presented that support the described algorithms. A low- cost 8-channel system with off-the-shelf componentry was designed and its performance evaluated. A massively parallel 512-channel custom-built system is in development-its capabilities and the rationale for its design are described.

  14. Energetics of the Brazil Current in the Rio Grande Cone region

    NASA Astrophysics Data System (ADS)

    Brum, André Lopes; Azevedo, José Luiz Lima de; Oliveira, Leopoldo Rota de; Calil, Paulo Henrique Rezende

    2017-10-01

    The energetics of the Brazil Current (BC) in the region of the Rio Grande Cone (RGC, 30-35.5°S), a topographic rise in the southwest portion of the Brazilian continental margin, are analyzed using 16 years of numerical data from the Ocean General Circulation Model (OGCM) for the Earth Simulator (OFES). The main focus of this study is the eddy-mean flow interactions of the BC and the local energy budgets in the study region. The kinetic and potential energy balance equations are derived for mean and eddy flows, and the resulting terms are presented and discussed. The eddy-mean flow interactions exhibit complex spatial distributions, and the intensities of the energy budgets decrease with increasing depth. However, only the mean potential energy (MPE) budget decreases southward. Eddy kinetic energy (EKE) and eddy potential energy (EPE) exhibit similar horizontal distribution patterns. Additionally, the baroclinic and barotropic conversion rates increase downstream of the bump, where the eddy energy field exhibits along-stream variability that increases southward. Barotropic conversion is more intense between 50 and 200 m, where mean kinetic energy (MKE) and EKE are concentrated, and it exhibits a horizontal cross-stream variation pattern, with mean-to-eddy energy conversion observed on the offshore side of the BC. This result indicates that the turbulence associated with the stream jet increases as the BC moves away from the coast, with the conversion term acting to stabilize the flow. Baroclinic conversion exhibits a high intensity below 300 m (where MPE and EPE display peaks), and it has a greater influence on the eddy-mean flow interaction than does the barotropic conversion. The RGC directly affects the local dynamics of the BC by increasing the eddy field as soon as the BC reaches the bump. The energy diagrams illustrate a stream characterized by evolving barotropic and baroclinic instability processes throughout the water column. This result indicates an intrinsically unstable jet in the study region. Moreover, baroclinic instability is the main source of EKE in the RGC region.

  15. Competing influence of greenhouse warming and aerosols on thermodynamic and dynamic controls of the Asian monoon

    NASA Astrophysics Data System (ADS)

    Lau, W. K. M.; Kim, K. M.

    2016-12-01

    In this study, we investigate the relative roles of greenhouse gas (GHG) warming and aerosol forcing on the Asian monsoon. A baseline for global warming response is established from analysis of the multi-model mean (MMM) of 33 CMIP5 models based on a 140-year integration of 1% per year CO2 experiment. The relative roles of GHG warming and aerosol forcing on Asian monsoon precipitation changes are then assessed based on the 20th century historical runs, under a) all-forcing including GHG and aerosols, and b) GHG only. Results show that under CO2 warming, the Asian monsoon atmosphere can get wetter, no change, or drier regionally, depending on changes in moisture availability, atmospheric moist static stability, and topography. Rainfall is generally increased over the Asian monsoon tropical land and adjacent oceanic regions. However, in subtropical and extratropical land region over East Asia, monsoon rainfall increase is minimal, unchanged, or even suppressed. This is due to increased subsidence, and reduction of mid-tropopsheric relative humidity from an enhanced Hadley circulation, which weakens the monsoon meridional overturning circulation. These create the apparent paradox of a monsoon with increased rainfall, but weakened monsoon circulation under GHG warming. The monsoon response to GHG-only forcing in the historical run is similar to the baseline. On the other hand, as inferred from the difference of the all-forcing and the GHG-only runs, aerosols through solar dimming (SDM) and semi-direct effects suppress monsoon precipitation, causing a further weakening of the Asian monsoon. A scale analysis of precipitation shows that under a hypothetical GHG-only forcing in the past century, the "effective precipitation efficiency" (EPE) would have to be strongly reduced in order to achieve water balance between dynamics and thermodynamics. Under all-forcing (including aerosol), the reduction in EPE is much smaller. Here, the weaker monsoon circulation needed for water balance can be achieved via the aerosol semi-direct effect in increased atmospheric stability, and aerosol solar dimming effect in lessening the GHG induced land-sea thermal contrast between Eurasia and the surrounding oceans.

  16. 3D printing-assisted preoperative plan of pedicle screw placement for middle-upper thoracic trauma: a cohort study.

    PubMed

    Xu, Wei; Zhang, Xuming; Ke, Tie; Cai, Hongru; Gao, Xiang

    2017-08-11

    This study aimed to evaluate the application of 3D printing in assisting preoperative plan of pedicle screw placement for treating middle-upper thoracic trauma. A preoperative plan was implemented in seven patients suffering from middle-upper thoracic (T3-T7) trauma between March 2013 and February 2016. In the 3D printing models, entry points of 56 pedicle screws (Magerl method) and 4 important parameters of the pedicle screws were measured, including optimal diameter (ϕ, mm), length (L, mm), inclined angle (α), head-tilting angle (+β), and tail-tilting angle (-β). In the surgery, bare-hands fixation of pedicle screws was performed using 3D printing models and the measured parameters as guidance. A total of seven patients were enrolled, including five men and two women, with the age of 21-62 years (mean age of 37.7 years). The position of the pedicle screw was evaluated postoperatively using a computerized tomography scan. Totally, 56 pedicle screws were placed, including 33 pieces of level 0, 18 pieces of level 1, 4 pieces of level 2 (pierced lateral wall), and 1 piece of level 3 (pierced lateral wall, no adverse consequences), with a fine rate of 91.0%. 3D printing technique is an intuitive and effective assistive technology to pedicle screw fixation for treating middle-upper thoracic vertebrae, which improve the accuracy of bare-hands screw placement and reduce empirical errors. The trial was approved by the Ethics Committee of the Fujian Provincial Hospital. It was registered on March 1st, 2013, and the registration number was K2013-03-001.

  17. Effects of Bullying Experience on Psychological Well-Being Mediated by Conflict Management Styles and Psychological Empowerment among Nursing Students in Clinical Placement: A Structural Equation Modeling Approach.

    PubMed

    Ren, Liping; Kim, Hyunli

    2017-10-01

    This study aimed to test a proposed structural equation model in which bullying experience, conflict management styles and psychological empowerment predict psychological well-being among Chinese nursing students in clinical placement. Three hundred and sixty-six nursing students recruited from five hospitals in J city and Y city were assessed with self-report questionnaires on bullying experience, conflict management styles, psychological empowerment and psychological well-being including depression, self-esteem, and academic major satisfaction. Data were analyzed using SPSS version 20.0 and AMOS version 22.0. The evaluation parameters included the comparative fit index at .90, the goodness of fit index at .93, the root mean square error of approximation at .07, and χ²/df ratio at 2.66, indicating that the proposed structural equation model provided a good fit to the data. Experience of being bullied during clinical placement, conflict management styles and psychological empowerment explained 93.0% of the variance and had significant effects on psychological well-being, with conflict management styles and psychological empowerment mediating the association between bullying and psychological well-being. The findings indicated that mediation by conflict management styles and psychological empowerment alleviated the negative influence of bullying on psychological well-being. To limit bullying and its negative effects, development of effective guidelines to deal with bullying will be a critical tool for both Chinese nursing students and their instructors. Further research should incorporate conflict management styles and psychological empowerment into the specific intervention strategies for handling bullying behaviors among nursing students and staff nurses and promoting nursing students' psychological well-being. © 2017 Korean Society of Nursing Science

  18. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lao, Lang L.; St John, Holger; Staebler, Gary M.

    This report describes the work done under U.S. Department of Energy grant number DE-FG02-07ER54935 for the period ending July 31, 2010. The goal of this project was to provide predictive transport analysis to the PTRANSP code. Our contribution to this effort consisted of three parts: (a) a predictive solver suitable for use with highly non-linear transport models and installation of the turbulent confinement models GLF23 and TGLF, (b) an interface of this solver with the PTRANSP code, and (c) initial development of an EPED1 edge pedestal model interface with PTRANSP. PTRANSP has been installed locally on this cluster by importingmore » a complete PTRANSP build environment that always contains the proper version of the libraries and other object files that PTRANSP requires. The GCNMP package and its interface code have been added to the SVN repository at PPPL.« less

  19. A linear programming approach for placement of applicants to academic programs.

    PubMed

    Kassa, Biniyam Asmare

    2013-01-01

    This paper reports a linear programming approach for placement of applicants to study programs developed and implemented at the college of Business & Economics, Bahir Dar University, Bahir Dar, Ethiopia. The approach is estimated to significantly streamline the placement decision process at the college by reducing required man hour as well as the time it takes to announce placement decisions. Compared to the previous manual system where only one or two placement criteria were considered, the new approach allows the college's management to easily incorporate additional placement criteria, if needed. Comparison of our approach against manually constructed placement decisions based on actual data for the 2012/13 academic year suggested that about 93 percent of the placements from our model concur with the actual placement decisions. For the remaining 7 percent of placements, however, the actual placements made by the manual system display inconsistencies of decisions judged against the very criteria intended to guide placement decisions by the college's program management office. Overall, the new approach proves to be a significant improvement over the manual system in terms of efficiency of the placement process and the quality of placement decisions.

  20. DIII-D research to address key challenges for ITER and fusion energy

    NASA Astrophysics Data System (ADS)

    Buttery, R. J.; the DIII-D Team

    2015-10-01

    DIII-D has made significant advances in the scientific basis for fusion energy. The physics mechanism of resonant magnetic perturbation (RMP) edge localized mode (ELM) suppression is revealed as field penetration at the pedestal top, and reduced coil set operation was demonstrated. Disruption runaway electrons were effectively quenched by shattered pellets; runaway dissipation is explained by pitch angle scattering. Modest thermal quench radiation asymmetries are well described NIMROD modelling. With good pedestal regulation and error field correction, low torque ITER baselines have been demonstrated and shown to be compatible with an ITER test blanket module simulator. However performance and long wavelength turbulence degrade as low rotation and electron heating are approached. The alternative QH mode scenario is shown to be compatible with high Greenwald density fraction, with an edge harmonic oscillation demonstrating good impurity flushing. Discharge optimization guided by the EPED model has discovered a new super H-mode with doubled pedestal height. Lithium injection also led to wider, higher pedestals. On the path to steady state, 1 MA has been sustained fully noninductively with βN = 4 and RMP ELM suppression, while a peaked current profile scenario provides attractive options for ITER and a βN = 5 future reactor. Energetic particle transport is found to exhibit a critical gradient behaviour. Scenarios are shown to be compatible with radiative and snowflake divertor techniques. Physics studies reveal that the transition to H mode is locked in by a rise in ion diamagnetic flows. Intrinsic rotation in the plasma edge is demonstrated to arise from kinetic losses. New 3D magnetic sensors validate linear ideal MHD, but identify issues in nonlinear simulations. Detachment, characterized in 2D with sub-eV resolution, reveals a radiation shortfall in simulations. Future facility development targets burning plasma physics with torque free electron heating, the path to steady state with increased off axis currents, and a new divertor solution for fusion reactors.

  1. Simulation-based MDP verification for leading-edge masks

    NASA Astrophysics Data System (ADS)

    Su, Bo; Syrel, Oleg; Pomerantsev, Michael; Hagiwara, Kazuyuki; Pearman, Ryan; Pang, Leo; Fujimara, Aki

    2017-07-01

    For IC design starts below the 20nm technology node, the assist features on photomasks shrink well below 60nm and the printed patterns of those features on masks written by VSB eBeam writers start to show a large deviation from the mask designs. Traditional geometry-based fracturing starts to show large errors for those small features. As a result, other mask data preparation (MDP) methods have become available and adopted, such as rule-based Mask Process Correction (MPC), model-based MPC and eventually model-based MDP. The new MDP methods may place shot edges slightly differently from target to compensate for mask process effects, so that the final patterns on a mask are much closer to the design (which can be viewed as the ideal mask), especially for those assist features. Such an alteration generally produces better masks that are closer to the intended mask design. Traditional XOR-based MDP verification cannot detect problems caused by eBeam effects. Much like model-based OPC verification which became a necessity for OPC a decade ago, we see the same trend in MDP today. Simulation-based MDP verification solution requires a GPU-accelerated computational geometry engine with simulation capabilities. To have a meaningful simulation-based mask check, a good mask process model is needed. The TrueModel® system is a field tested physical mask model developed by D2S. The GPU-accelerated D2S Computational Design Platform (CDP) is used to run simulation-based mask check, as well as model-based MDP. In addition to simulation-based checks such as mask EPE or dose margin, geometry-based rules are also available to detect quality issues such as slivers or CD splits. Dose margin related hotspots can also be detected by setting a correct detection threshold. In this paper, we will demonstrate GPU-acceleration for geometry processing, and give examples of mask check results and performance data. GPU-acceleration is necessary to make simulation-based mask MDP verification acceptable.

  2. DIII-D research to address key challenges for ITER and fusion energy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Buttery, Richard J.

    DIII-D has made significant advances in the scientific basis for fusion energy. The physics mechanism of resonant magnetic perturbation (RMP) edge localized mode (ELM) suppression is revealed as field penetration at the pedestal top, and reduced coil set operation was demonstrated. Disruption runaway electrons were effectively quenched by shattered pellets; runaway dissipation is explained by pitch angle scattering. Modest thermal quench radiation asymmetries are well described NIMROD modeling. With good pedestal regulation and error field correction, low torque ITER baselines have been demonstrated and shown to be compatible with an ITER test blanket module simulator. However performance and long wavelengthmore » turbulence degrade as low rotation and electron heating are approached. The alternative QH mode scenario is shown to be compatible with high Greenwald density fraction, with an edge harmonic oscillation demonstrating good impurity flushing. Discharge optimization guided by the EPED model has discovered a new super H-mode with doubled pedestal height. Lithium injection also led to wider, higher pedestals. On the path to steady state, 1 MA has been sustained fully non inductively with β N = 4 and RMP ELM suppression, while a peaked current profile scenario provides attractive options for ITER and a β N = 5 future reactor. Energetic particle transport is found to exhibit a critical gradient behavior. Scenarios are shown to be compatible with radiative and snowflake diverter techniques. Physics studies reveal that the transition to H mode is locked in by a rise in ion diamagnetic flows. Intrinsic rotation in the plasma edge is demonstrated to arise from kinetic losses. New 3D magnetic sensors validate linear ideal MHD, but identify issues in nonlinear simulations. Detachment, characterized in 2D with sub-eV resolution, reveals a radiation shortfall in simulations. As a result, future facility development targets burning plasma physics with torque free electron heating, the path to steady state with increased off axis currents, and a new divertor solution for fusion reactors.« less

  3. DIII-D research to address key challenges for ITER and fusion energy

    DOE PAGES

    Buttery, Richard J.

    2015-07-29

    DIII-D has made significant advances in the scientific basis for fusion energy. The physics mechanism of resonant magnetic perturbation (RMP) edge localized mode (ELM) suppression is revealed as field penetration at the pedestal top, and reduced coil set operation was demonstrated. Disruption runaway electrons were effectively quenched by shattered pellets; runaway dissipation is explained by pitch angle scattering. Modest thermal quench radiation asymmetries are well described NIMROD modeling. With good pedestal regulation and error field correction, low torque ITER baselines have been demonstrated and shown to be compatible with an ITER test blanket module simulator. However performance and long wavelengthmore » turbulence degrade as low rotation and electron heating are approached. The alternative QH mode scenario is shown to be compatible with high Greenwald density fraction, with an edge harmonic oscillation demonstrating good impurity flushing. Discharge optimization guided by the EPED model has discovered a new super H-mode with doubled pedestal height. Lithium injection also led to wider, higher pedestals. On the path to steady state, 1 MA has been sustained fully non inductively with β N = 4 and RMP ELM suppression, while a peaked current profile scenario provides attractive options for ITER and a β N = 5 future reactor. Energetic particle transport is found to exhibit a critical gradient behavior. Scenarios are shown to be compatible with radiative and snowflake diverter techniques. Physics studies reveal that the transition to H mode is locked in by a rise in ion diamagnetic flows. Intrinsic rotation in the plasma edge is demonstrated to arise from kinetic losses. New 3D magnetic sensors validate linear ideal MHD, but identify issues in nonlinear simulations. Detachment, characterized in 2D with sub-eV resolution, reveals a radiation shortfall in simulations. As a result, future facility development targets burning plasma physics with torque free electron heating, the path to steady state with increased off axis currents, and a new divertor solution for fusion reactors.« less

  4. Evaluation of a new electronic preoperative reference marker for toric intraocular lens implantation by two different methods of analysis: Adobe Photoshop versus iTrace

    PubMed Central

    Farooqui, Javed Hussain; Sharma, Mansi; Koul, Archana; Dutta, Ranjan; Shroff, Noshir Minoo

    2017-01-01

    PURPOSE: The aim of this study is to compare two different methods of analysis of preoperative reference marking for toric intraocular lens (IOL) after marking with an electronic marker. SETTING/VENUE: Cataract and IOL Implantation Service, Shroff Eye Centre, New Delhi, India. PATIENTS AND METHODS: Fifty-two eyes of thirty patients planned for toric IOL implantation were included in the study. All patients had preoperative marking performed with an electronic preoperative two-step toric IOL reference marker (ASICO AE-2929). Reference marks were placed at 3-and 9-o'clock positions. Marks were analyzed with two systems. First, slit-lamp photographs taken and analyzed using Adobe Photoshop (version 7.0). Second, Tracey iTrace Visual Function Analyzer (version 5.1.1) was used for capturing corneal topograph examination and position of marks noted. Amount of alignment error was calculated. RESULTS: Mean absolute rotation error was 2.38 ± 1.78° by Photoshop and 2.87 ± 2.03° by iTrace which was not statistically significant (P = 0.215). Nearly 72.7% of eyes by Photoshop and 61.4% by iTrace had rotation error ≤3° (P = 0.359); and 90.9% of eyes by Photoshop and 81.8% by iTrace had rotation error ≤5° (P = 0.344). No significant difference in absolute amount of rotation between eyes when analyzed by either method. CONCLUSIONS: Difference in reference mark positions when analyzed by two systems suggests the presence of varying cyclotorsion at different points of time. Both analysis methods showed an approximately 3° of alignment error, which could contribute to 10% loss of astigmatic correction of toric IOL. This can be further compounded by intra-operative marking errors and final placement of IOL in the bag. PMID:28757694

  5. Meraculous: De Novo Genome Assembly with Short Paired-End Reads

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chapman, Jarrod A.; Ho, Isaac; Sunkara, Sirisha

    2011-08-18

    We describe a new algorithm, meraculous, for whole genome assembly of deep paired-end short reads, and apply it to the assembly of a dataset of paired 75-bp Illumina reads derived from the 15.4 megabase genome of the haploid yeast Pichia stipitis. More than 95% of the genome is recovered, with no errors; half the assembled sequence is in contigs longer than 101 kilobases and in scaffolds longer than 269 kilobases. Incorporating fosmid ends recovers entire chromosomes. Meraculous relies on an efficient and conservative traversal of the subgraph of the k-mer (deBruijn) graph of oligonucleotides with unique high quality extensions inmore » the dataset, avoiding an explicit error correction step as used in other short-read assemblers. A novel memory-efficient hashing scheme is introduced. The resulting contigs are ordered and oriented using paired reads separated by ~280 bp or ~3.2 kbp, and many gaps between contigs can be closed using paired-end placements. Practical issues with the dataset are described, and prospects for assembling larger genomes are discussed.« less

  6. An IMU-to-Body Alignment Method Applied to Human Gait Analysis

    PubMed Central

    Vargas-Valencia, Laura Susana; Elias, Arlindo; Rocon, Eduardo; Bastos-Filho, Teodiano; Frizera, Anselmo

    2016-01-01

    This paper presents a novel calibration procedure as a simple, yet powerful, method to place and align inertial sensors with body segments. The calibration can be easily replicated without the need of any additional tools. The proposed method is validated in three different applications: a computer mathematical simulation; a simplified joint composed of two semi-spheres interconnected by a universal goniometer; and a real gait test with five able-bodied subjects. Simulation results demonstrate that, after the calibration method is applied, the joint angles are correctly measured independently of previous sensor placement on the joint, thus validating the proposed procedure. In the cases of a simplified joint and a real gait test with human volunteers, the method also performs correctly, although secondary plane errors appear when compared with the simulation results. We believe that such errors are caused by limitations of the current inertial measurement unit (IMU) technology and fusion algorithms. In conclusion, the presented calibration procedure is an interesting option to solve the alignment problem when using IMUs for gait analysis. PMID:27973406

  7. Statistical exchange-coupling errors and the practicality of scalable silicon donor qubits

    NASA Astrophysics Data System (ADS)

    Song, Yang; Das Sarma, S.

    2016-12-01

    Recent experimental efforts have led to considerable interest in donor-based localized electron spins in Si as viable qubits for a scalable silicon quantum computer. With the use of isotopically purified 28Si and the realization of extremely long spin coherence time in single-donor electrons, the recent experimental focus is on two-coupled donors with the eventual goal of a scaled-up quantum circuit. Motivated by this development, we simulate the statistical distribution of the exchange coupling J between a pair of donors under realistic donor placement straggles, and quantify the errors relative to the intended J value. With J values in a broad range of donor-pair separation ( 5 <|R |<60 nm), we work out various cases systematically, for a target donor separation R0 along the [001], [110] and [111] Si crystallographic directions, with |R0|=10 ,20 or 30 nm and standard deviation σR=1 ,2 ,5 or 10 nm. Our extensive theoretical results demonstrate the great challenge for a prescribed J gate even with just a donor pair, a first step for any scalable Si-donor-based quantum computer.

  8. Analysis of the Space Shuttle main engine simulation

    NASA Technical Reports Server (NTRS)

    Deabreu-Garcia, J. Alex; Welch, John T.

    1993-01-01

    This is a final report on an analysis of the Space Shuttle Main Engine Program, a digital simulator code written in Fortran. The research was undertaken in ultimate support of future design studies of a shuttle life-extending Intelligent Control System (ICS). These studies are to be conducted by NASA Lewis Space Research Center. The primary purpose of the analysis was to define the means to achieve a faster running simulation, and to determine if additional hardware would be necessary for speeding up simulations for the ICS project. In particular, the analysis was to consider the use of custom integrators based on the Matrix Stability Region Placement (MSRP) method. In addition to speed of execution, other qualities of the software were to be examined. Among these are the accuracy of computations, the useability of the simulation system, and the maintainability of the program and data files. Accuracy involves control of truncation error of the methods, and roundoff error induced by floating point operations. It also involves the requirement that the user be fully aware of the model that the simulator is implementing.

  9. Design of a Tool Integrating Force Sensing With Automated Insertion in Cochlear Implantation

    PubMed Central

    Schurzig, Daniel; Labadie, Robert F.; Hussong, Andreas; Rau, Thomas S.; Webster, Robert J.

    2012-01-01

    The quality of hearing restored to a deaf patient by a cochlear implant in hearing preservation cochlear implant surgery (and possibly also in routine cochlear implant surgery) is believed to depend on preserving delicate cochlear membranes while accurately inserting an electrode array deep into the spiral cochlea. Membrane rupture forces, and possibly, other indicators of suboptimal placement, are below the threshold detectable by human hands, motivating a force sensing insertion tool. Furthermore, recent studies have shown significant variability in manual insertion forces and velocities that may explain some instances of imperfect placement. Toward addressing this, an automated insertion tool was recently developed by Hussong et al. By following the same insertion tool concept, in this paper, we present mechanical enhancements that improve the surgeon’s interface with the device and make it smaller and lighter. We also present electomechanical design of new components enabling integrated force sensing. The tool is designed to be sufficiently compact and light that it can be mounted to a microstereotactic frame for accurate image-guided preinsertion positioning. The new integrated force sensing system is capable of resolving forces as small as 0.005 N, and we provide experimental illustration of using forces to detect errors in electrode insertion. PMID:23482414

  10. Prospective comparison of virtual fluoroscopy to fluoroscopy and plain radiographs for placement of lumbar pedicle screws.

    PubMed

    Resnick, Daniel K

    2003-06-01

    Fluoroscopy-based frameless stereotactic systems provide feedback to the surgeon using virtual fluoroscopic images. The real-life accuracy of these virtual images has not been compared with traditional fluoroscopy in a clinical setting. We prospectively studied 23 consecutive cases. In two cases, registration errors precluded the use of virtual fluoroscopy. Pedicle probes placed with virtual fluoroscopic imaging were imaged with traditional fluoroscopy in the remaining 21 cases. Position of the probes was judged to be ideal, acceptable but not ideal, or not acceptable based on the traditional fluoroscopic images. Virtual fluoroscopy was used to place probes in for 97 pedicles from L1 to the sacrum. Eighty-eight probes were judged to be in ideal position, eight were judged to be acceptable but not ideal, and one probe was judged to be in an unacceptable position. This probe was angled toward an adjacent disc space. Therefore, 96 of 97 probes placed using virtual fluoroscopy were found to be in an acceptable position. The positive predictive value for acceptable screw placement with virtual fluoroscopy compared with traditional fluoroscopy was 99%. A probe placed with virtual fluoroscopic guidance will be judged to be in an acceptable position when imaged with traditional fluoroscopy 99% of the time.

  11. Predictors of professional placement outcome: cultural background, English speaking and international student status.

    PubMed

    Attrill, Stacie; McAllister, Sue; Lincoln, Michelle

    2016-08-01

    Placements provide opportunities for students to develop practice skills in professional settings. Learning in placements may be challenging for culturally and linguistically diverse (CALD) students, international students, or those without sufficient English proficiency for professional practice. This study investigated whether these factors, which are hypothesized to influence acculturation, predict poor placement outcome. Placement outcome data were collected for 854 students who completed 2747 placements. Placement outcome was categorized into 'Pass' or 'At risk' categories. Multilevel binomial regression analysis was used to determine whether being CALD, an international student, speaking 'English as an additional language', or a 'Language other than English at home' predicted placement outcome. In multiple multilevel analysis speaking English as an additional language and being an international student were significant predictors of 'at risk' placements, but other variables tested were not. Effect sizes were small indicating untested factors also influenced placement outcome. These results suggest that students' English as an additional language or international student status influences success in placements. The extent of acculturation may explain the differences in placement outcome for the groups tested. This suggests that learning needs for placement may differ for students undertaking more acculturative adjustments. Further research is needed to understand this and to identify placement support strategies.

  12. Planning, guidance, and quality assurance of pelvic screw placement using deformable image registration

    NASA Astrophysics Data System (ADS)

    Goerres, J.; Uneri, A.; Jacobson, M.; Ramsay, B.; De Silva, T.; Ketcha, M.; Han, R.; Manbachi, A.; Vogt, S.; Kleinszig, G.; Wolinsky, J.-P.; Osgood, G.; Siewerdsen, J. H.

    2017-12-01

    Percutaneous pelvic screw placement is challenging due to narrow bone corridors surrounded by vulnerable structures and difficult visual interpretation of complex anatomical shapes in 2D x-ray projection images. To address these challenges, a system for planning, guidance, and quality assurance (QA) is presented, providing functionality analogous to surgical navigation, but based on robust 3D-2D image registration techniques using fluoroscopy images already acquired in routine workflow. Two novel aspects of the system are investigated: automatic planning of pelvic screw trajectories and the ability to account for deformation of surgical devices (K-wire deflection). Atlas-based registration is used to calculate a patient-specific plan of screw trajectories in preoperative CT. 3D-2D registration aligns the patient to CT within the projective geometry of intraoperative fluoroscopy. Deformable known-component registration (dKC-Reg) localizes the surgical device, and the combination of plan and device location is used to provide guidance and QA. A leave-one-out analysis evaluated the accuracy of automatic planning, and a cadaver experiment compared the accuracy of dKC-Reg to rigid approaches (e.g. optical tracking). Surgical plans conformed within the bone cortex by 3-4 mm for the narrowest corridor (superior pubic ramus) and  >5 mm for the widest corridor (tear drop). The dKC-Reg algorithm localized the K-wire tip within 1.1 mm and 1.4° and was consistently more accurate than rigid-body tracking (errors up to 9 mm). The system was shown to automatically compute reliable screw trajectories and accurately localize deformed surgical devices (K-wires). Such capability could improve guidance and QA in orthopaedic surgery, where workflow is impeded by manual planning, conventional tool trackers add complexity and cost, rigid tool assumptions are often inaccurate, and qualitative interpretation of complex anatomy from 2D projections is prone to trial-and-error with extended fluoroscopy time.

  13. Inheriting the Learner's View: A Google Glass-Based Wearable Computing Platform for Improving Surgical Trainee Performance.

    PubMed

    Brewer, Zachary E; Fann, Hutchinson C; Ogden, W David; Burdon, Thomas A; Sheikh, Ahmad Y

    2016-01-01

    It is speculated that, in operative environments, real-time visualization of the trainee's viewpoint by the instructor may improve performance and teaching efficacy. We hypothesized that introduction of a wearable surgical visualization system allowing the instructor to visualize otherwise "blind" areas in the operative field could improve trainee performance in a simulated operative setting. A total of 11 surgery residents (4 in general surgery training and 7 in an integrated 6-year cardiothoracic surgery program) participated in the study. Google (Mountain View, CA) Glass hardware running proprietary software from CrowdOptic (San Francisco, CA) was utilized for creation of the wearable surgical visualization system. Both the learner and trainer wore the system, and video was streamed from the learner's system in real time to the trainer, who directed the learner to place needles in a simulated operative field. Subjects placed a total of 5 needles in each of 4 quadrants. A composite error score was calculated based on the accuracy of needle placement in relation to the intended needle trajectories as described by the trainer. Time to task completion (TTC) was also measured and participants completed an exit questionnaire. All residents completed the protocol tasks and the survey. Introduction of the wearable surgical visualization system did not affect mean time to task completion (278 ± 50 vs. 282 ± 69 seconds, p = NS). However, mean composite error score fell significantly once the wearable system was deployed (18 ± 5 vs. 15 ± 4, p < 0.05), demonstrating improved accuracy of needle placement. Most of the participants deemed the device unobtrusive, easy to operate, and useful for communication and instruction. This study suggests that wearable surgical visualization systems allowing for adoption of the learner's perspective may be a useful educational adjunct in the training of surgeons. Further evaluations of the efficacy of wearable technology in the operating room environment are warranted. Copyright © 2016 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.

  14. Consistent evaluation of an ultrasound-guided surgical navigation system by utilizing an active validation platform

    NASA Astrophysics Data System (ADS)

    Kim, Younsu; Kim, Sungmin; Boctor, Emad M.

    2017-03-01

    An ultrasound image-guided needle tracking systems have been widely used due to their cost-effectiveness and nonionizing radiation properties. Various surgical navigation systems have been developed by utilizing state-of-the-art sensor technologies. However, ultrasound transmission beam thickness causes unfair initial evaluation conditions due to inconsistent placement of the target with respect to the ultrasound probe. This inconsistency also brings high uncertainty and results in large standard deviations for each measurement when we compare accuracy with and without the guidance. To resolve this problem, we designed a complete evaluation platform by utilizing our mid-plane detection and time of flight measurement systems. The evaluating system uses a PZT element target and an ultrasound transmitting needle. In this paper, we evaluated an optical tracker-based surgical ultrasound-guided navigation system whereby the optical tracker tracks marker frames attached on the ultrasound probe and the needle. We performed ten needle trials of guidance experiment with a mid-plane adjustment algorithm and with a B-mode segmentation method. With the midplane adjustment, the result showed a mean error of 1.62+/-0.72mm. The mean error increased to 3.58+/-2.07mm without the mid-plane adjustment. Our evaluation system can reduce the effect of the beam-thickness problem, and measure ultrasound image-guided technologies consistently with a minimal standard deviation. Using our novel evaluation system, ultrasound image-guided technologies can be compared under equal initial conditions. Therefore, the error can be evaluated more accurately, and the system provides better analysis on the error sources such as ultrasound beam thickness.

  15. The importance of expert feedback during endovascular simulator training.

    PubMed

    Boyle, Emily; O'Keeffe, Dara A; Naughton, Peter A; Hill, Arnold D K; McDonnell, Ciaran O; Moneley, Daragh

    2011-07-01

    Complex endovascular skills are difficult to obtain in the clinical environment. Virtual reality (VR) simulator training is a valuable addition to current training curricula, but is there a benefit in the absence of expert trainers? Eighteen endovascular novices performed a renal artery angioplasty/stenting (RAS) on the Vascular Interventional Surgical Trainer simulator. They were randomized into three groups: Group A (n = 6, control), no performance feedback; Group B (n = 6, nonexpert feedback), feedback after every procedure from a nonexpert facilitator; and Group C (n = 6, expert feedback), feedback after every procedure from a consultant vascular surgeon. Each trainee completed RAS six times. Simulator-measured performance metrics included procedural and fluoroscopy time, contrast volume, accuracy of balloon placement, and handling errors. Clinical errors were also measured by blinded video assessment. Data were analyzed using SPSS version 15. A clear learning curve was observed across the six trials. There were no significant differences between the three groups for the general performance metrics, but Group C made fewer errors than Groups A (P = .009) or B (P = .004). Video-based error assessment showed that Groups B and C performed better than Group A (P = .002 and P = .000, respectively). VR simulator training for novices can significantly improve general performance in the absence of expert trainers. Procedure-specific qualitative metrics are improved with expert feedback, but nonexpert facilitators can also enhance the quality of training and may represent a valuable alternative to expert clinical faculty. Copyright © 2011 Society for Vascular Surgery. Published by Mosby, Inc. All rights reserved.

  16. Global Warming Estimation from MSU: Correction for Drift and Calibration Errors

    NASA Technical Reports Server (NTRS)

    Prabhakara, C.; Iacovazzi, R., Jr.; Yoo, J.-M.

    2000-01-01

    Microwave Sounding Unit (MSU) radiometer observations in Ch 2 (53.74 GHz), made in the nadir direction from sequential, sun-synchronous, polar-orbiting NOAA morning satellites (NOAA 6, 10 and 12 that have approximately 7am/7pm orbital geometry) and. afternoon satellites (NOAA 7, 9, 11 and 14 that have approximately 2am/2pm orbital geometry) are analyzed in this study to derive global temperature trend from 1980 to 1998. In order to remove the discontinuities between the data of the successive satellites and to get a continuous time series, first we have used shortest possible time record of each satellite. In this way we get a preliminary estimate of the global temperature trend of 0.21 K/decade. However, this estimate is affected by systematic time-dependent errors. One such error is the instrument calibration error eo. This error can be inferred whenever there are overlapping measurements made by two satellites over an extended period of time. From the available successive satellite data we have taken the longest possible time record of each satellite to form the time series during the period 1980 to 1998 to this error eo. We find eo can decrease the global temperature trend by approximately 0.07 K/decade. In addition there are systematic time dependent errors ed and ec present in the data that are introduced by the drift in the satellite orbital geometry. ed arises from the diurnal cycle in temperature and ec is the drift related change in the calibration of the MSU. In order to analyze the nature of these drift related errors the multi-satellite Ch 2 data set is partitioned into am and pm subsets to create two independent time series. The error ed can be assessed in the am and pm data of Ch 2 on land and can be eliminated. Observation made in the MSU Ch 1 (50.3 GHz) support this approach. The error ec is obvious only in the difference between the pm and am observations of Ch 2 over the ocean. We have followed two different paths to assess the impact of the error ec on the global temperature trend. In one path the entire error ec is placed in the am data while in the other it is placed in the pm data. Global temperature trend is increased or decreased by approximately 0.03 K/decade depending upon this placement. Taking into account all random errors and systematic errors our analysis of MSU observations leads us to conclude that a conservative estimate of the global warming is 0. 11 (+/-) 0.04 K/decade during 1980 to 1998.

  17. 25 CFR 26.25 - What constitutes a complete Job Placement Program application?

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 25 Indians 1 2011-04-01 2011-04-01 false What constitutes a complete Job Placement Program... JOB PLACEMENT AND TRAINING PROGRAM Job Placement Services § 26.25 What constitutes a complete Job Placement Program application? To be complete, a Job Placement Program application must contain all of the...

  18. 25 CFR 26.25 - What constitutes a complete Job Placement Program application?

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 25 Indians 1 2012-04-01 2011-04-01 true What constitutes a complete Job Placement Program... JOB PLACEMENT AND TRAINING PROGRAM Job Placement Services § 26.25 What constitutes a complete Job Placement Program application? To be complete, a Job Placement Program application must contain all of the...

  19. 25 CFR 26.25 - What constitutes a complete Job Placement Program application?

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 25 Indians 1 2014-04-01 2014-04-01 false What constitutes a complete Job Placement Program... JOB PLACEMENT AND TRAINING PROGRAM Job Placement Services § 26.25 What constitutes a complete Job Placement Program application? To be complete, a Job Placement Program application must contain all of the...

  20. 25 CFR 26.25 - What constitutes a complete Job Placement Program application?

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 25 Indians 1 2013-04-01 2013-04-01 false What constitutes a complete Job Placement Program... JOB PLACEMENT AND TRAINING PROGRAM Job Placement Services § 26.25 What constitutes a complete Job Placement Program application? To be complete, a Job Placement Program application must contain all of the...

  1. On the use of mobile phones and wearable microphones for noise exposure measurements: Calibration and measurement accuracy

    NASA Astrophysics Data System (ADS)

    Dumoulin, Romain

    Despite the fact that noise-induced hearing loss remains the number one occupational disease in developed countries, individual noise exposure levels are still rarely known and infrequently tracked. Indeed, efforts to standardize noise exposure levels present disadvantages such as costly instrumentation and difficulties associated with on site implementation. Given their advanced technical capabilities and widespread daily usage, mobile phones could be used to measure noise levels and make noise monitoring more accessible. However, the use of mobile phones for measuring noise exposure is currently limited due to the lack of formal procedures for their calibration and challenges regarding the measurement procedure. Our research investigated the calibration of mobile phone-based solutions for measuring noise exposure using a mobile phone's built-in microphones and wearable external microphones. The proposed calibration approach integrated corrections that took into account microphone placement error. The corrections were of two types: frequency-dependent, using a digital filter and noise level-dependent, based on the difference between the C-weighted noise level minus A-weighted noise level of the noise measured by the phone. The electro-acoustical limitations and measurement calibration procedure of the mobile phone were investigated. The study also sought to quantify the effect of noise exposure characteristics on the accuracy of calibrated mobile phone measurements. Measurements were carried out in reverberant and semi-anechoic chambers with several mobiles phone units of the same model, two types of external devices (an earpiece and a headset with an in-line microphone) and an acoustical test fixture (ATF). The proposed calibration approach significantly improved the accuracy of the noise level measurements in diffuse and free fields, with better results in the diffuse field and with ATF positions causing little or no acoustic shadowing. Several sources of errors and uncertainties were identified including the errors associated with the inter-unit-variability, the presence of signal saturation and the microphone placement relative to the source and the wearer. The results of the investigations and validation measurements led to recommendations regarding the measurement procedure including the use of external microphones having lower sensitivity and provided the basis for a standardized and unique factory default calibration method intended for implementation in any mobile phone. A user-defined adjustment was proposed to minimize the errors associated with calibration and the acoustical field. Mobile phones implementing the proposed laboratory calibration and used with external microphones showed great potential as noise exposure instruments. Combined with their potential as training and prevention tools, the expansion of their use could significantly help reduce the risks of noise-induced hearing loss.

  2. Navigation accuracy comparing non-covered frame and use of plastic sterile drapes to cover the reference frame in 3D acquisition.

    PubMed

    Corenman, Donald S; Strauch, Eric L; Dornan, Grant J; Otterstrom, Eric; Zalepa King, Lisa

    2017-09-01

    Advancements in surgical navigation technology coupled with 3-dimensional (3D) radiographic data have significantly enhanced the accuracy and efficiency of spinal fusion implant placement. Increased usage of such technology has led to rising concerns regarding maintenance of the sterile field, as makeshift drape systems are fraught with breaches thus presenting increased risk of surgical site infections (SSIs). A clinical need exists for a sterile draping solution with these techniques. Our objective was to quantify expected accuracy error associated with 2MM and 4MM thickness Sterile-Z Patient Drape ® using Medtronic O-Arm ® Surgical Imaging with StealthStation ® S7 ® Navigation System. Camera distance to reference frame was investigated for contribution to accuracy error. A testing jig was placed on the radiolucent table and the Medtronic passive reference frame was attached to jig. The StealthStation ® S7 ® navigation camera was placed at various distances from testing jig and the geometry error of reference frame was captured for three different drape configurations: no drape, 2MM drape and 4MM drape. The O-Arm ® gantry location and StealthStation ® S7 ® camera position was maintained and seven 3D acquisitions for each of drape configurations were measured. Data was analyzed by a two-factor analysis of variance (ANOVA) and Bonferroni comparisons were used to assess the independent effects of camera angle and drape on accuracy error. Median (and maximum) measurement accuracy error was higher for the 2MM than for the 4MM drape for each camera distance. The most extreme error observed (4.6 mm) occurred when using the 2MM and the 'far' camera distance. The 4MM drape was found to induce an accuracy error of 0.11 mm (95% confidence interval, 0.06-0.15; P<0.001) relative to the no drape testing, regardless of camera distance. Medium camera distance produced lower accuracy error than either the close (additional 0.08 mm error; 95% CI, 0-0.15; P=0.035) or far (additional 0.21mm error; 95% CI, 0.13-0.28; P<0.001) camera distances, regardless of whether a drape was used. In comparison to the 'no drape' condition, the accuracy error of 0.11 mm when using a 4MM film drape is minimal and clinically insignificant.

  3. Safety and Efficacy of Electromagnetic-Guided Bedside Placement of Nasoenteral Feeding Tubes versus Standard Placement.

    PubMed

    Shadid, Husam; Keckeisen, Maureen; Zarrinpar, Ali

    2017-10-01

    Although enteral feeding in critically ill patients has been shown to be beneficial, reliable postpyloric placement of feeding tubes remains a challenge. The standard of care involves blind placement, frequently requiring multiple attempts, and radiographs. To evaluate the effect of electromagnetic-guided bedside placement in reducing time to establishment of feeding, lung placement, use of radiography, and cost, we initiated a prospective trial using electromagnetic-guided bedside placement and compared them to a retrospective cohort. Fifty-three consecutive placements of nasoenteral feeding tubes were made using electromagnetic-guidance on patients requiring enteral nutrition in a surgical intensive care unit at a tertiary care center. Sixty-three placement attempts in the preceding seven months served as controls. There were no significant differences between the two groups in terms of age, sex, weight, body mass index, hiatal or ventral hernias, or previous esophageal/gastric operations. The number of radiographs needed per patient, need for fluoroscopy, radiology charge per patient for the tube placement, and time from first attempt at placement to confirmation of postpyloric location were lower for the electromagnetic-guided group. Use of electromagnetic guidance allows reliable and cost-effective postpyloric enteral feeding tube placement compared with blind insertion.

  4. Improved Apparatus for Measuring Distance Between Axles

    NASA Technical Reports Server (NTRS)

    Willard, Douglas E.; Townsend, Ivan I., III

    2003-01-01

    An improved version of an optoelectronic apparatus for measuring distances of the order of tens of feet with an error no larger than a small fraction of an inch (a few millimeters) has been built. Like the previous version, the present improved version of the apparatus is designed to measure the distance approximately equal to 66 ft (approximately equal to 20 m) between the axes of rotation of the front and rear tires of the space shuttle orbiter as it rests in a ground-based processing facility. Like the previous version, the present version could also be adapted for similar purposes in other settings: Examples include measuring perpendicular distance from a wall in a building, placement of architectural foundations, and general alignment and measurement operations.

  5. Latency as a region contrast: Measuring ERP latency differences with Dynamic Time Warping.

    PubMed

    Zoumpoulaki, A; Alsufyani, A; Filetti, M; Brammer, M; Bowman, H

    2015-12-01

    Methods for measuring onset latency contrasts are evaluated against a new method utilizing the dynamic time warping (DTW) algorithm. This new method allows latency to be measured across a region instead of single point. We use computer simulations to compare the methods' power and Type I error rates under different scenarios. We perform per-participant analysis for different signal-to-noise ratios and two sizes of window (broad vs. narrow). In addition, the methods are tested in combination with single-participant and jackknife average waveforms for different effect sizes, at the group level. DTW performs better than the other methods, being less sensitive to noise as well as to placement and width of the window selected. © 2015 Society for Psychophysiological Research.

  6. Theoretical studies of system performance and adaptive optics design parameters

    NASA Astrophysics Data System (ADS)

    Tyson, Robert K.

    1990-08-01

    The ultimate performance of an adaptive optics (AO) system can be sensitive to specific design parameters of individual components. The type and configuration of a wavefront sensor or the shape of individual deformable mirror actuator influence functions can have a profound effect on the correctability of the AO system. This paper will discuss the results of a theoretical study which employed both closed form analytic solutions and computer models. A parametric analysis of wavefront sensor characteristics, noise, and subaperture geometry are independently evaluated against system response to an aberrated wave characteristic of atmospheric turbulence. Similarly, the shape and extent of the deformable mirror influence function and the placement and number of actuators is evaluated to characterize the effects of fitting error and coupling.

  7. An FPGA Noise Resistant Digital Temperature Sensor with Auto Calibration

    DTIC Science & Technology

    2012-03-01

    temperature sensor [6] . . . . . . . . . . . . . . 14 9 Two different digital temperature sensor placement algorithms: (a) Grid placement (b) Optimal...create a grid over the FPGA. While this method works reasonably well, it requires many sensors, some of which are unnecessary. The optimal placement, on...temperature sensor placement algorithms: (a) Grid placement (b) Optimal Placement [7] 16 2.4 Summary Integrated circuits’ sensitivity to temperatures has

  8. Self-aligned block technology: a step toward further scaling

    NASA Astrophysics Data System (ADS)

    Lazzarino, Frédéric; Mohanty, Nihar; Feurprier, Yannick; Huli, Lior; Luong, Vinh; Demand, Marc; Decoster, Stefan; Vega Gonzalez, Victor; Ryckaert, Julien; Kim, Ryan Ryoung Han; Mallik, Arindam; Leray, Philippe; Wilson, Chris; Boemmels, Jürgen; Kumar, Kaushik; Nafus, Kathleen; deVilliers, Anton; Smith, Jeffrey; Fonseca, Carlos; Bannister, Julie; Scheer, Steven; Tokei, Zsolt; Piumi, Daniele; Barla, Kathy

    2017-04-01

    In this work, we present and compare two integration approaches to enable self-alignment of the block suitable for the 5- nm technology node. The first approach is exploring the insertion of a spin-on metal-based material to memorize the first block and act as an etch stop layer in the overall integration. The second approach is evaluating the self-aligned block technology employing widely used organic materials and well-known processes. The concept and the motivation are discussed considering the effects on design and mask count as well as the impact on process complexity and EPE budget. We show the integration schemes and discuss the requirements to enable self-alignment. We present the details of materials and processes selection to allow optimal selective etches and we demonstrate the proof of concept using a 16- nm half-pitch BEOL vehicle. Finally, a study on technology insertion and cost estimation is presented.

  9. Eosinophilic Pleural Effusion: A Rare Manifestation of Hypereosinophilic Syndrome

    PubMed Central

    Okafor, Ndubuisi C.; Oso, Ayodeji A.; Oranu, Amanke C.; Wolff, Steven M.; Murray, John J.

    2009-01-01

    Several causes of eosinophilic pleural effusions have been described with malignancy being the commonest cause. Hypereosinophilic syndrome (HES) is a rare disease and very few cases have been reported of HES presenting as eosinophilic pleural effusion (EPE). We report a case of a 26-year-old male who presented with shortness of breath. He had bilateral pleural effusions, generalized lymphadenopathy, splenomegaly, and leukocytosis with marked peripheral blood eosinophilia. The pleural fluid was exudative, with 25%–30% eosinophilis, and absence of neoplastic cells. Hypereosinophilic syndrome was diagnosed after other causes of eosinophilia were excluded. He continued to be dyspneic with persistent accumulation of eosinophilic pleural fluid, even after his peripheral eosinophil count had normalized in response to treatment. This patient represents a very unusual presentation of HES with dyspnea and pleural effusions and demonstrates that treatment based on response of peripheral eosinophil counts, as is currently recommended, may not always be clinically adequate. PMID:20111739

  10. Eosinophilic pleural effusion: a rare manifestation of hypereosinophilic syndrome.

    PubMed

    Okafor, Ndubuisi C; Oso, Ayodeji A; Oranu, Amanke C; Wolff, Steven M; Murray, John J

    2009-01-01

    Several causes of eosinophilic pleural effusions have been described with malignancy being the commonest cause. Hypereosinophilic syndrome (HES) is a rare disease and very few cases have been reported of HES presenting as eosinophilic pleural effusion (EPE). We report a case of a 26-year-old male who presented with shortness of breath. He had bilateral pleural effusions, generalized lymphadenopathy, splenomegaly, and leukocytosis with marked peripheral blood eosinophilia. The pleural fluid was exudative, with 25%-30% eosinophilis, and absence of neoplastic cells. Hypereosinophilic syndrome was diagnosed after other causes of eosinophilia were excluded. He continued to be dyspneic with persistent accumulation of eosinophilic pleural fluid, even after his peripheral eosinophil count had normalized in response to treatment. This patient represents a very unusual presentation of HES with dyspnea and pleural effusions and demonstrates that treatment based on response of peripheral eosinophil counts, as is currently recommended, may not always be clinically adequate.

  11. Dependence of pedestal properties on plasma parameters

    NASA Astrophysics Data System (ADS)

    Kim, S. K.; Na, Y.-S.; Saarelma, S.; Kwon, O.

    2018-01-01

    We have numerically investigated the dependence of pedestal properties such as the pedestal height and the pedestal width on various global parameters using the EURO-DEMO as the reference equilibrium. We have used EPED, a predictive model of the edge pedestal. Among global parameters, we have chosen to vary the triangularity, δ , the elongation, κ , and the poloidal beta, {{β }p} , which have larger effects on the pedestal properties. Improvement of pedestal properties can be achieved for more shaped plasma boundary. However, the increase in the pedestal height and the width with δ saturates around δ ∼ 0.6. Also, the pedestal width saturates and the pedestal temperature starts to decrease for κ >1.9 . Improvement of the pedestal properties due to δ is larger at higher poloidal beta. The pedestal width slightly increases with the electron density at the pedestal top and the effective charge number.

  12. Placement education pedagogy as social participation: what are students really learning?

    PubMed

    Kell, Clare

    2014-03-01

    This paper draws on empirical fieldwork data of naturally occurring UK physiotherapy placement education to make visible how education is actually carried out and suggest what students may be learning through their placement interactions. The data challenge everyone involved in placement education design and practice to consider the values and practices students are learning to perpetuate through placement education experiences. The researcher undertook an ethnomethodologically informed ethnographic observation of naturally occurring physiotherapy placement education in two UK NHS placement sites. This study adopted a social perspective of learning to focus on the minutiae of placement educator, student and patient interaction practices during student-present therapeutic activities. Two days of placement for each of six senior students were densely recorded in real-time focussing specifically on the verbal, kinesics and proxemics-based elements of the participants' interaction practices. Repeated cycles of data analysis suggested consistent practices irrespective of the placement, educators, students or patients. The data suggest that placement education is a powerful situated learning environment in which students see, experience and learn to reproduce the physiotherapy practices valued by the local placement. Consistently, placement educators and students co-produced patient-facing activities as spectacles of physiotherapy-as-science. In each setting, patients were used as person-absent audiovisual teaching aids from which students learnt to make a case for physiotherapy intervention. The paper challenges physiotherapists and other professions using work-placement education to look behind the rhetoric of their placement documentation and explore the reality of students' learning in the field. The UK-based physiotherapy profession may wish to consider further the possible implications of its self-definition as a 'science-based healthcare profession' on its in-the-presence-of-students interactions with patients. Copyright © 2013 John Wiley & Sons, Ltd.

  13. Preoperative short hookwire placement for small pulmonary lesions: evaluation of technical success and risk factors for initial placement failure.

    PubMed

    Iguchi, Toshihiro; Hiraki, Takao; Matsui, Yusuke; Fujiwara, Hiroyasu; Masaoka, Yoshihisa; Tanaka, Takashi; Sato, Takuya; Gobara, Hideo; Toyooka, Shinichi; Kanazawa, Susumu

    2018-05-01

    To retrospectively evaluate the technical success of computed tomography fluoroscopy-guided short hookwire placement before video-assisted thoracoscopic surgery and to identify the risk factors for initial placement failure. In total, 401 short hookwire placements for 401 lesions (mean diameter 9.3 mm) were reviewed. Technical success was defined as correct positioning of the hookwire. Possible risk factors for initial placement failure (i.e., requirement for placement of an additional hookwire or to abort the attempt) were evaluated using logistic regression analysis for all procedures, and for procedures performed via the conventional route separately. Of the 401 initial placements, 383 were successful and 18 failed. Short hookwires were finally placed for 399 of 401 lesions (99.5%). Univariate logistic regression analyses revealed that in all 401 procedures only the transfissural approach was a significant independent predictor of initial placement failure (odds ratio, OR, 15.326; 95% confidence interval, CI, 5.429-43.267; p < 0.001) and for the 374 procedures performed via the conventional route only lesion size was a significant independent predictor of failure (OR 0.793, 95% CI 0.631-0.996; p = 0.046). The technical success of preoperative short hookwire placement was extremely high. The transfissural approach was a predictor initial placement failure for all procedures and small lesion size was a predictor of initial placement failure for procedures performed via the conventional route. • Technical success of preoperative short hookwire placement was extremely high. • The transfissural approach was a significant independent predictor of initial placement failure for all procedures. • Small lesion size was a significant independent predictor of initial placement failure for procedures performed via the conventional route.

  14. Body-mounted robotic instrument guide for image-guided cryotherapy of renal cancer

    PubMed Central

    Hata, Nobuhiko; Song, Sang-Eun; Olubiyi, Olutayo; Arimitsu, Yasumichi; Fujimoto, Kosuke; Kato, Takahisa; Tuncali, Kemal; Tani, Soichiro; Tokuda, Junichi

    2016-01-01

    Purpose: Image-guided cryotherapy of renal cancer is an emerging alternative to surgical nephrectomy, particularly for those who cannot sustain the physical burden of surgery. It is well known that the outcome of this therapy depends on the accurate placement of the cryotherapy probe. Therefore, a robotic instrument guide may help physicians aim the cryotherapy probe precisely to maximize the efficacy of the treatment and avoid damage to critical surrounding structures. The objective of this paper was to propose a robotic instrument guide for orienting cryotherapy probes in image-guided cryotherapy of renal cancers. The authors propose a body-mounted robotic guide that is expected to be less susceptible to guidance errors caused by the patient’s whole body motion. Methods: Keeping the device’s minimal footprint in mind, the authors developed and validated a body-mounted, robotic instrument guide that can maintain the geometrical relationship between the device and the patient’s body, even in the presence of the patient’s frequent body motions. The guide can orient the cryotherapy probe with the skin incision point as the remote-center-of-motion. The authors’ validation studies included an evaluation of the mechanical accuracy and position repeatability of the robotic instrument guide. The authors also performed a mock MRI-guided cryotherapy procedure with a phantom to compare the advantage of robotically assisted probe replacements over a free-hand approach, by introducing organ motions to investigate their effects on the accurate placement of the cryotherapy probe. Measurements collected for performance analysis included accuracy and time taken for probe placements. Multivariate analysis was performed to assess if either or both organ motion and the robotic guide impacted these measurements. Results: The mechanical accuracy and position repeatability of the probe placement using the robotic instrument guide were 0.3 and 0.1 mm, respectively, at a depth of 80 mm. The phantom test indicated that the accuracy of probe placement was significantly better with the robotic instrument guide (4.1 mm) than without the guide (6.3 mm, p<0.001), even in the presence of body motion. When independent organ motion was artificially added, in addition to body motion, the advantage of accurate probe placement using the robotic instrument guide disappeared statistically [i.e., 6.0 mm with the robotic guide and 5.9 mm without the robotic guide (p = 0.906)]. When the robotic instrument guide was used, the total time required to complete the procedure was reduced from 19.6 to 12.7 min (p<0.001). Multivariable analysis indicated that the robotic instrument guide, not the organ motion, was the cause of statistical significance. The statistical power the authors obtained was 88% in accuracy assessment and 99% higher in duration measurement. Conclusions: The body-mounted robotic instrument guide allows positioning of the probe during image-guided cryotherapy of renal cancer and was done in fewer attempts and in less time than the free-hand approach. The accuracy of the placement of the cryotherapy probe was better using the robotic instrument guide than without the guide when no organ motion was present. The accuracy between the robotic and free-hand approach becomes comparable when organ motion was present. PMID:26843245

  15. Effect of placements (horizontal with vertical) on gas-solid flow and particle impact erosion in gate valve

    NASA Astrophysics Data System (ADS)

    Lin, Zhe; Zhu, Linhang; Cui, Baoling; Li, Yi; Ruan, Xiaodong

    2014-12-01

    Gate valve has various placements in the practical usages. Due to the effect of gravity, particle trajectories and erosions are distinct between placements. Thus in this study, gas-solid flow properties and erosion in gate valve for horizontal placement and vertical placement are discussed and compared by using Euler-Lagrange simulation method. The structure of a gate valve and a simplified structure are investigated. The simulation procedure is validated in our published paper by comparing with the experiment data of a pipe and an elbow. The results show that for all investigated open degrees and Stokes numbers (St), there are little difference of gas flow properties and flow coefficients between two placements. It is also found that the trajectories of particles for two placements are mostly identical when St « 1, making the erosion independent of placement. With the increase of St, the distinction of trajectories between placements becomes more obvious, leading to an increasing difference of the erosion distributions. Besides, the total erosion ratio of surface T for horizontal placement is two orders of magnitudes larger than that for vertical placement when the particle diameter is 250μm.

  16. Benign tracheobronchial stenoses: changes in short-term and long-term pulmonary function testing after expandable metallic stent placement.

    PubMed

    Gotway, Michael B; Golden, Jeffrey A; LaBerge, Jeanne M; Webb, W Richard; Reddy, Gautham P; Wilson, Mark W; Kerlan, Robert K; Gordon, Roy L

    2002-01-01

    To determine the short- and long-term improvement in airflow dynamics in patients undergoing tracheobronchial stent placement for benign airway stenoses. Twenty-two patients underwent 34 tracheal and/or bronchial stent placement procedures for benign airway stenoses and had the results of pulmonary function tests available. Stent placement indications included bronchomalacia after lung transplantation (n = 11), postintubation stenoses (n = 6), relapsing polychondritis (n = 2), and 1 each of tracheomalacia, tracheal compression, and histoplasmosis. Six patients underwent more than one stent placement procedure (range: 2-7 procedures). The mean forced expiratory volume in one second (FEV(1) ), forced expiratory flow rate in the midportion of the forced vital capacity curve (FEF(25-75) ), forced vital capacity, and peak flow (PF) rate obtained before stent placement were compared with those immediately after stent placement and with those measurements most remote from stent placement using the paired two-tailed test. All patients reported improved respiratory function immediately after stent placement. The mean FEV(1), FEF(25-75), and PF rate improved significantly (p < 0.001, p = 0.002, and p = 0.009, respectively) after stent placement. On long-term follow-up averaging 15 months after stent placement, these parameters declined despite patients' subjective sense of improvement. Segregating the population into transplant and nontransplant airway stenosis etiologies, however, FEF(25-75) and PF rate remained significantly improved (p = 0.045, p = 0.027, respectively), over the long term for the latter. FEV increased after subsequent stent placements for patients receiving multiple stents. Stent placement for benign tracheobronchial stenoses provides significant immediate improvement in airflow dynamics. Long-term improvement in airflow obstruction may be expected, and additional stent placements may further improve pulmonary function.

  17. 25 CFR 26.4 - Who administers the Job Placement and Training Program?

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 25 Indians 1 2010-04-01 2010-04-01 false Who administers the Job Placement and Training Program... PLACEMENT AND TRAINING PROGRAM General Applicability § 26.4 Who administers the Job Placement and Training Program? The Job Placement and Training Program is administered by the Bureau of Indian Affairs or a...

  18. The Placement Handbook. A Guide for the Competitive Employment of the Handicapped.

    ERIC Educational Resources Information Center

    Horn, Adelaide; Drury, Stephen

    This handbook stresses those components that are considered peripheral to the placement process but that must precede the actual placement. The philosophy of placement upon which this guide is based appears first. Discussions follow of the basic components of the process of training and placement of handicapped individuals, including a varied…

  19. Standard Transistor Array (STAR). Volume 1: Placement technique

    NASA Technical Reports Server (NTRS)

    Cox, G. W.; Caroll, B. D.

    1979-01-01

    A large scale integration (LSI) technology, the standard transistor array uses a prefabricated understructure of transistors and a comprehensive library of digital logic cells to allow efficient fabrication of semicustom digital LSI circuits. The cell placement technique for this technology involves formation of a one dimensional cell layout and "folding" of the one dimensional placement onto the chip. It was found that, by use of various folding methods, high quality chip layouts can be achieved. Methods developed to measure of the "goodness" of the generated placements include efficient means for estimating channel usage requirements and for via counting. The placement and rating techniques were incorporated into a placement program (CAPSTAR). By means of repetitive use of the folding methods and simple placement improvement strategies, this program provides near optimum placements in a reasonable amount of time. The program was tested on several typical LSI circuits to provide performance comparisons both with respect to input parameters and with respect to the performance of other placement techniques. The results of this testing indicate that near optimum placements can be achieved by use of the procedures incurring severe time penalties.

  20. Functional variants of human papillomavirus type 16 demonstrate host genome integration and transcriptional alterations corresponding to their unique cancer epidemiology.

    PubMed

    Jackson, Robert; Rosa, Bruce A; Lameiras, Sonia; Cuninghame, Sean; Bernard, Josee; Floriano, Wely B; Lambert, Paul F; Nicolas, Alain; Zehbe, Ingeborg

    2016-11-02

    Human papillomaviruses (HPVs) are a worldwide burden as they are a widespread group of tumour viruses in humans. Having a tropism for mucosal tissues, high-risk HPVs are detected in nearly all cervical cancers. HPV16 is the most common high-risk type but not all women infected with high-risk HPV develop a malignant tumour. Likely relevant, HPV genomes are polymorphic and some HPV16 single nucleotide polymorphisms (SNPs) are under evolutionary constraint instigating variable oncogenicity and immunogenicity in the infected host. To investigate the tumourigenicity of two common HPV16 variants, we used our recently developed, three-dimensional organotypic model reminiscent of the natural HPV infectious cycle and conducted various "omics" and bioinformatics approaches. Based on epidemiological studies we chose to examine the HPV16 Asian-American (AA) and HPV16 European Prototype (EP) variants. They differ by three non-synonymous SNPs in the transforming and virus-encoded E6 oncogene where AAE6 is classified as a high- and EPE6 as a low-risk variant. Remarkably, the high-risk AAE6 variant genome integrated into the host DNA, while the low-risk EPE6 variant genome remained episomal as evidenced by highly sensitive Capt-HPV sequencing. RNA-seq experiments showed that the truncated form of AAE6, integrated in chromosome 5q32, produced a local gene over-expression and a large variety of viral-human fusion transcripts, including long distance spliced transcripts. In addition, differential enrichment of host cell pathways was observed between both HPV16 E6 variant-containing epithelia. Finally, in the high-risk variant, we detected a molecular signature of host chromosomal instability, a common property of cancer cells. We show how naturally occurring SNPs in the HPV16 E6 oncogene cause significant changes in the outcome of HPV infections and subsequent viral and host transcriptome alterations prone to drive carcinogenesis. Host genome instability is closely linked to viral integration into the host genome of HPV-infected cells, which is a key phenomenon for malignant cellular transformation and the reason for uncontrolled E6 oncogene expression. In particular, the finding of variant-specific integration potential represents a new paradigm in HPV variant biology.

  1. Using Xbox kinect motion capture technology to improve clinical rehabilitation outcomes for balance and cardiovascular health in an individual with chronic TBI.

    PubMed

    Chanpimol, Shane; Seamon, Bryant; Hernandez, Haniel; Harris-Love, Michael; Blackman, Marc R

    2017-01-01

    Motion capture virtual reality-based rehabilitation has become more common. However, therapists face challenges to the implementation of virtual reality (VR) in clinical settings. Use of motion capture technology such as the Xbox Kinect may provide a useful rehabilitation tool for the treatment of postural instability and cardiovascular deconditioning in individuals with chronic severe traumatic brain injury (TBI). The primary purpose of this study was to evaluate the effects of a Kinect-based VR intervention using commercially available motion capture games on balance outcomes for an individual with chronic TBI. The secondary purpose was to assess the feasibility of this intervention for eliciting cardiovascular adaptations. A single system experimental design ( n = 1) was utilized, which included baseline, intervention, and retention phases. Repeated measures were used to evaluate the effects of an 8-week supervised exercise intervention using two Xbox One Kinect games. Balance was characterized using the dynamic gait index (DGI), functional reach test (FRT), and Limits of Stability (LOS) test on the NeuroCom Balance Master. The LOS assesses end-point excursion (EPE), maximal excursion (MXE), and directional control (DCL) during weight-shifting tasks. Cardiovascular and activity measures were characterized by heart rate at the end of exercise (HRe), total gameplay time (TAT), and time spent in a therapeutic heart rate (TTR) during the Kinect intervention. Chi-square and ANOVA testing were used to analyze the data. Dynamic balance, characterized by the DGI, increased during the intervention phase χ 2 (1, N = 12) = 12, p = .001. Static balance, characterized by the FRT showed no significant changes. The EPE increased during the intervention phase in the backward direction χ 2 (1, N = 12) = 5.6, p = .02, and notable improvements of DCL were demonstrated in all directions. HRe ( F (2,174) = 29.65, p = < .001) and time in a TTR ( F (2, 12) = 4.19, p = .04) decreased over the course of the intervention phase. Use of a supervised Kinect-based program that incorporated commercial games improved dynamic balance for an individual post severe TBI. Additionally, moderate cardiovascular activity was achieved through motion capture gaming. Further studies appear warranted to determine the potential therapeutic utility of commercial VR games in this patient population. Clinicaltrial.gov ID - NCT02889289.

  2. Prospective comparison of PI-RADS version 2 and qualitative in-house categorization system in detection of prostate cancer.

    PubMed

    Gaur, Sonia; Harmon, Stephanie; Mehralivand, Sherif; Bednarova, Sandra; Calio, Brian P; Sugano, Dordaneh; Sidana, Abhinav; Merino, Maria J; Pinto, Peter A; Wood, Bradford J; Shih, Joanna H; Choyke, Peter L; Turkbey, Baris

    2018-03-31

    Prostate Imaging-Reporting and Data System v. 2 (PI-RADSv2) provides standardized nomenclature for interpretation of prostate multiparametric MRI (mpMRI). Inclusion of additional features for categorization may provide benefit to stratification of disease. To prospectively compare PI-RADSv2 to a qualitative in-house system for detecting prostate cancer on mpMRI. Prospective. In all, 338 patients who underwent mpMRI May 2015-May 2016, with subsequent MRI/transrectal ultrasound fusion-guided biopsy. 3T mpMRI (T 2 W, diffusion-weighted [DW], apparent diffusion coefficient [ADC] map, b-2000 DWI acquisition, and dynamic contrast-enhanced [DCE] MRI). One genitourinary radiologist prospectively read mpMRIs using both in-house and PI-RADSv2 5-category systems. In lesion-based analysis, overall and clinically significant (CS) tumor detection rates (TDR) were calculated for all PI-RADSv2 and in-house categories. The ability of each scoring system to detect cancer was assessed by area under receiver operator characteristic curve (AUC). Within each PI-RADSv2 category, lesions were further stratified by their in-house categories to determine if TDRs can be increased by combining features of both systems. In 338 patients (median prostate-specific antigen [PSA] 6.5 [0.6-113.6] ng/mL; age 64 [44-84] years), 733 lesions were identified (47% tumor-positive). Predictive abilities of both systems were comparable for all (AUC 76-78%) and CS cancers (AUCs 79%). The in-house system had higher overall and CS TDRs than PI-RADSv2 for categories 3 and 4 (P < 0.01 for both), with the greatest difference between the scoring systems seen in lesions scored category 4 (CS TDRs: in-house 65%, PI-RADSv2 22.1%). For lesions categorized as PI-RADSv2 = 4, characterization of suspicious/indeterminate extraprostatic extension (EPE) and equivocal findings across all mpMRI sequences contributed to significantly different TDRs for both systems (TDR range 19-75%, P < 0.05). PI-RADSv2 behaves similarly to an existing validated system that relies on the number of sequences on which a lesion is seen. This prospective evaluation suggests that sequence positivity and suspicion of EPE can enhance PI-RADSv2 category 4 cancer detection. 1 Technical Efficacy: Stage 3 J. Magn. Reson. Imaging 2018. © 2018 International Society for Magnetic Resonance in Medicine.

  3. 25 CFR 26.26 - What Job Placement services may I receive?

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 25 Indians 1 2014-04-01 2014-04-01 false What Job Placement services may I receive? 26.26 Section 26.26 Indians BUREAU OF INDIAN AFFAIRS, DEPARTMENT OF THE INTERIOR HUMAN SERVICES JOB PLACEMENT AND TRAINING PROGRAM Job Placement Services § 26.26 What Job Placement services may I receive? As determined by...

  4. 25 CFR 26.26 - What Job Placement services may I receive?

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 25 Indians 1 2013-04-01 2013-04-01 false What Job Placement services may I receive? 26.26 Section 26.26 Indians BUREAU OF INDIAN AFFAIRS, DEPARTMENT OF THE INTERIOR HUMAN SERVICES JOB PLACEMENT AND TRAINING PROGRAM Job Placement Services § 26.26 What Job Placement services may I receive? As determined by...

  5. 25 CFR 26.26 - What Job Placement services may I receive?

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 25 Indians 1 2012-04-01 2011-04-01 true What Job Placement services may I receive? 26.26 Section 26.26 Indians BUREAU OF INDIAN AFFAIRS, DEPARTMENT OF THE INTERIOR HUMAN SERVICES JOB PLACEMENT AND TRAINING PROGRAM Job Placement Services § 26.26 What Job Placement services may I receive? As determined by...

  6. 25 CFR 26.26 - What Job Placement services may I receive?

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 25 Indians 1 2011-04-01 2011-04-01 false What Job Placement services may I receive? 26.26 Section 26.26 Indians BUREAU OF INDIAN AFFAIRS, DEPARTMENT OF THE INTERIOR HUMAN SERVICES JOB PLACEMENT AND TRAINING PROGRAM Job Placement Services § 26.26 What Job Placement services may I receive? As determined by...

  7. 25 CFR 26.26 - What Job Placement services may I receive?

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 25 Indians 1 2010-04-01 2010-04-01 false What Job Placement services may I receive? 26.26 Section 26.26 Indians BUREAU OF INDIAN AFFAIRS, DEPARTMENT OF THE INTERIOR HUMAN SERVICES JOB PLACEMENT AND TRAINING PROGRAM Job Placement Services § 26.26 What Job Placement services may I receive? As determined by...

  8. Accuracy of three different types of stereolithographic surgical guide in implant placement: an in vitro study.

    PubMed

    Turbush, Sarah Katherine; Turkyilmaz, Ilser

    2012-09-01

    Precise treatment planning before implant surgery is necessary to identify vital structures and to ensure a predictable restorative outcome. The purpose of this study was to compare the accuracy of implant placement by using 3 different types of surgical guide: bone-supported, tooth-supported, and mucosa-supported. Thirty acrylic resin mandibles were fabricated with stereolithography (SLA) based on data from the cone beam computerized tomography (CBCT) scan of an edentulous patient. Ten of the mandibles were modified digitally before fabrication with the addition of 4 teeth, and 10 of the mandibles were modified after fabrication with soft acrylic resin to simulate mucosa. Each acrylic resin mandible had 5 implants virtually planned in a 3-D software program. A total of 150 implants were planned and placed by using SLA guides. Presurgical and postsurgical CBCT scans were superimposed to compare the virtual implant placement with the actual implant placement. For statistical analyses, a linear mixed models approach and t-test with the 2-sided alpha level set at .016 were used. All reported P values were adjusted by the Dunn-Sidak method to control the Type I error rate across multiple pairwise comparisons. The mean angular deviation of the long axis between the planned and placed implants was 2.2 ±1.2 degrees; the mean deviations in linear distance between the planned and placed implants were 1.18 ±0.42 mm at the implant neck and 1.44 ±0.67 mm at the implant apex for all 150 implants. After the superimposition procedure, the angular deviation of the placed implants was 2.26 ±1.30 degrees with the tooth-supported, 2.17 ±1.02 degrees with the bone-supported, and 2.29 ±1.28 degrees with the mucosa-supported SLA guide. The mean deviations in linear distance between the planned and placed implants at the neck and apex were 1.00 ±0.33 mm and 1.15 ±0.42 mm for the tooth-supported guides; 1.08 ±0.33 mm and 1.53 ±0.90 mm for the bone-supported guides; and 1.47 ±0.43 mm and 1.65 ±0.48 mm for the mucosa-supported SLA surgical guides. The results of this study show that stereolithographic surgical guides may be reliable in implant placement and that: 1) there was no statistically significant difference among the 3 types of guide when comparing angular deviation and 2) mucosa-supported guides were less accurate than both tooth-supported and bone-supported guides for linear deviation at the implant neck and apex. Copyright © 2012 The Editorial Council of the Journal of Prosthetic Dentistry. Published by Mosby, Inc. All rights reserved.

  9. Network placement optimization for large-scale distributed system

    NASA Astrophysics Data System (ADS)

    Ren, Yu; Liu, Fangfang; Fu, Yunxia; Zhou, Zheng

    2018-01-01

    The network geometry strongly influences the performance of the distributed system, i.e., the coverage capability, measurement accuracy and overall cost. Therefore the network placement optimization represents an urgent issue in the distributed measurement, even in large-scale metrology. This paper presents an effective computer-assisted network placement optimization procedure for the large-scale distributed system and illustrates it with the example of the multi-tracker system. To get an optimal placement, the coverage capability and the coordinate uncertainty of the network are quantified. Then a placement optimization objective function is developed in terms of coverage capabilities, measurement accuracy and overall cost. And a novel grid-based encoding approach for Genetic algorithm is proposed. So the network placement is optimized by a global rough search and a local detailed search. Its obvious advantage is that there is no need for a specific initial placement. At last, a specific application illustrates this placement optimization procedure can simulate the measurement results of a specific network and design the optimal placement efficiently.

  10. Does out-of-home placement mediate the relationship between child maltreatment and adult criminality?

    PubMed

    DeGue, Sarah; Spatz Widom, Cathy

    2009-11-01

    Existing research on child welfare interventions as mediators of the criminal consequences of child maltreatment has focused on juvenile delinquency rather than adult criminality. This study uses a prospective sample of 772 maltreated youth to examine out-of-home placement as a mediator of adult criminality. Arrest data were collected from official records when the full sample was a mean age of 31.8, having ample opportunity for involvement with the criminal justice system. Overall, out-of-home placement showed a neutral or slightly positive effect on adult criminality compared to no placement, consistent with earlier findings. However, prior delinquency and placement instability were significant risk factors for adult criminality. Gender, not race, was identified as a significant moderator of the relationship between placement and adult criminality, with different patterns of response to placement for males and females. Thus, whether placement experiences influence adult criminal consequences of child maltreatment might depend on prior delinquency, placement stability, and gender.

  11. Empirical OPC rule inference for rapid RET application

    NASA Astrophysics Data System (ADS)

    Kulkarni, Anand P.

    2006-10-01

    A given technological node (45 nm, 65 nm) can be expected to process thousands of individual designs. Iterative methods applied at the node consume valuable days in determining proper placement of OPC features, and manufacturing and testing mask correspondence to wafer patterns in a trial-and-error fashion for each design. Repeating this fabrication process for each individual design is a time-consuming and expensive process. We present a novel technique which sidesteps the requirement to iterate through the model-based OPC analysis and pattern verification cycle on subsequent designs at the same node. Our approach relies on the inference of rules from a correct pattern at the wafer surface it relates to the OPC and pre-OPC pattern layout files. We begin with an offline phase where we obtain a "gold standard" design file that has been fab-tested at the node with a prepared, post-OPC layout file that corresponds to the intended on-wafer pattern. We then run an offline analysis to infer rules to be used in this method. During the analysis, our method implicitly identifies contextual OPC strategies for optimal placement of RET features on any design at that node. Using these strategies, we can apply OPC to subsequent designs at the same node with accuracy comparable to the original design file but significantly smaller expected runtimes. The technique promises to offer a rapid and accurate complement to existing RET application strategies.

  12. Needle path planning and steering in a three-dimensional non-static environment using two-dimensional ultrasound images

    PubMed Central

    Vrooijink, Gustaaf J.; Abayazid, Momen; Patil, Sachin; Alterovitz, Ron; Misra, Sarthak

    2015-01-01

    Needle insertion is commonly performed in minimally invasive medical procedures such as biopsy and radiation cancer treatment. During such procedures, accurate needle tip placement is critical for correct diagnosis or successful treatment. Accurate placement of the needle tip inside tissue is challenging, especially when the target moves and anatomical obstacles must be avoided. We develop a needle steering system capable of autonomously and accurately guiding a steerable needle using two-dimensional (2D) ultrasound images. The needle is steered to a moving target while avoiding moving obstacles in a three-dimensional (3D) non-static environment. Using a 2D ultrasound imaging device, our system accurately tracks the needle tip motion in 3D space in order to estimate the tip pose. The needle tip pose is used by a rapidly exploring random tree-based motion planner to compute a feasible needle path to the target. The motion planner is sufficiently fast such that replanning can be performed repeatedly in a closed-loop manner. This enables the system to correct for perturbations in needle motion, and movement in obstacle and target locations. Our needle steering experiments in a soft-tissue phantom achieves maximum targeting errors of 0.86 ± 0.35 mm (without obstacles) and 2.16 ± 0.88 mm (with a moving obstacle). PMID:26279600

  13. Test-retest reliability of the Clinical Learning Environment, Supervision and Nurse Teacher (CLES + T) scale.

    PubMed

    Gustafsson, Margareta; Blomberg, Karin; Holmefur, Marie

    2015-07-01

    The Clinical Learning Environment, Supervision and Nurse Teacher (CLES + T) scale evaluates the student nurses' perception of the learning environment and supervision within the clinical placement. It has never been tested in a replication study. The aim of the present study was to evaluate the test-retest reliability of the CLES + T scale. The CLES + T scale was administered twice to a group of 42 student nurses, with a one-week interval. Test-retest reliability was determined by calculations of Intraclass Correlation Coefficients (ICCs) and weighted Kappa coefficients. Standard Error of Measurements (SEM) and Smallest Detectable Difference (SDD) determined the precision of individual scores. Bland-Altman plots were created for analyses of systematic differences between the test occasions. The results of the study showed that the stability over time was good to excellent (ICC 0.88-0.96) in the sub-dimensions "Supervisory relationship", "Pedagogical atmosphere on the ward" and "Role of the nurse teacher". Measurements of "Premises of nursing on the ward" and "Leadership style of the manager" had lower but still acceptable stability (ICC 0.70-0.75). No systematic differences occurred between the test occasions. This study supports the usefulness of the CLES + T scale as a reliable measure of the student nurses' perception of the learning environment within the clinical placement at a hospital. Copyright © 2015 Elsevier Ltd. All rights reserved.

  14. Towards human-controlled, real-time shape sensing based flexible needle steering for MRI-guided percutaneous therapies.

    PubMed

    Li, Meng; Li, Gang; Gonenc, Berk; Duan, Xingguang; Iordachita, Iulian

    2017-06-01

    Accurate needle placement into soft tissue is essential to percutaneous prostate cancer diagnosis and treatment procedures. This paper discusses the steering of a 20 gauge (G) FBG-integrated needle with three sets of Fiber Bragg Grating (FBG) sensors. A fourth-order polynomial shape reconstruction method is introduced and compared with previous approaches. To control the needle, a bicycle model based navigation method is developed to provide visual guidance lines for clinicians. A real-time model updating method is proposed for needle steering inside inhomogeneous tissue. A series of experiments were performed to evaluate the proposed needle shape reconstruction, visual guidance and real-time model updating methods. Targeting experiments were performed in soft plastic phantoms and in vitro tissues with insertion depths ranging between 90 and 120 mm. Average targeting errors calculated based upon the acquired camera images were 0.40 ± 0.35 mm in homogeneous plastic phantoms, 0.61 ± 0.45 mm in multilayer plastic phantoms and 0.69 ± 0.25 mm in ex vivo tissue. Results endorse the feasibility and accuracy of the needle shape reconstruction and visual guidance methods developed in this work. The approach implemented for the multilayer phantom study could facilitate accurate needle placement efforts in real inhomogeneous tissues. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  15. A species-level phylogeny of all extant and late Quaternary extinct mammals using a novel heuristic-hierarchical Bayesian approach.

    PubMed

    Faurby, Søren; Svenning, Jens-Christian

    2015-03-01

    Across large clades, two problems are generally encountered in the estimation of species-level phylogenies: (a) the number of taxa involved is generally so high that computation-intensive approaches cannot readily be utilized and (b) even for clades that have received intense study (e.g., mammals), attention has been centered on relatively few selected species, and most taxa must therefore be positioned on the basis of very limited genetic data. Here, we describe a new heuristic-hierarchical Bayesian approach and use it to construct a species-level phylogeny for all extant and late Quaternary extinct mammals. In this approach, species with large quantities of genetic data are placed nearly freely in the mammalian phylogeny according to these data, whereas the placement of species with lower quantities of data is performed with steadily stricter restrictions for decreasing data quantities. The advantages of the proposed method include (a) an improved ability to incorporate phylogenetic uncertainty in downstream analyses based on the resulting phylogeny, (b) a reduced potential for long-branch attraction or other types of errors that place low-data taxa far from their true position, while maintaining minimal restrictions for better-studied taxa, and (c) likely improved placement of low-data taxa due to the use of closer outgroups. Copyright © 2014 Elsevier Inc. All rights reserved.

  16. The Phylogeny of Rickettsia Using Different Evolutionary Signatures: How Tree-Like is Bacterial Evolution?

    PubMed Central

    Murray, Gemma G. R.; Weinert, Lucy A.; Rhule, Emma L.; Welch, John J.

    2016-01-01

    Rickettsia is a genus of intracellular bacteria whose hosts and transmission strategies are both impressively diverse, and this is reflected in a highly dynamic genome. Some previous studies have described the evolutionary history of Rickettsia as non-tree-like, due to incongruity between phylogenetic reconstructions using different portions of the genome. Here, we reconstruct the Rickettsia phylogeny using whole-genome data, including two new genomes from previously unsampled host groups. We find that a single topology, which is supported by multiple sources of phylogenetic signal, well describes the evolutionary history of the core genome. We do observe extensive incongruence between individual gene trees, but analyses of simulations over a single topology and interspersed partitions of sites show that this is more plausibly attributed to systematic error than to horizontal gene transfer. Some conflicting placements also result from phylogenetic analyses of accessory genome content (i.e., gene presence/absence), but we argue that these are also due to systematic error, stemming from convergent genome reduction, which cannot be accommodated by existing phylogenetic methods. Our results show that, even within a single genus, tests for gene exchange based on phylogenetic incongruence may be susceptible to false positives. PMID:26559010

  17. Hand-eye calibration using a target registration error model.

    PubMed

    Chen, Elvis C S; Morgan, Isabella; Jayarathne, Uditha; Ma, Burton; Peters, Terry M

    2017-10-01

    Surgical cameras are prevalent in modern operating theatres and are often used as a surrogate for direct vision. Visualisation techniques (e.g. image fusion) made possible by tracking the camera require accurate hand-eye calibration between the camera and the tracking system. The authors introduce the concept of 'guided hand-eye calibration', where calibration measurements are facilitated by a target registration error (TRE) model. They formulate hand-eye calibration as a registration problem between homologous point-line pairs. For each measurement, the position of a monochromatic ball-tip stylus (a point) and its projection onto the image (a line) is recorded, and the TRE of the resulting calibration is predicted using a TRE model. The TRE model is then used to guide the placement of the calibration tool, so that the subsequent measurement minimises the predicted TRE. Assessing TRE after each measurement produces accurate calibration using a minimal number of measurements. As a proof of principle, they evaluated guided calibration using a webcam and an endoscopic camera. Their endoscopic camera results suggest that millimetre TRE is achievable when at least 15 measurements are acquired with the tracker sensor ∼80 cm away on the laparoscope handle for a target ∼20 cm away from the camera.

  18. Job Placement in Germany: Developments before and after Deregulation. IAB Labour Market Research Topics No. 31.

    ERIC Educational Resources Information Center

    Walwei, Ulrich

    Since 1994, the German public employment service has not had a monopoly on placement. A new law permits private job placement as an independent activity, but only with a license from the public employment service. Since deregulation, the number of job placement licenses has increased continuously, but the number of placements made by private…

  19. Social Work Program. Field Placement Manual for Social Work Field Placement I, Social Work Field Placement II.

    ERIC Educational Resources Information Center

    Miller, Howard J.; And Others

    This document is a manual for a social work field placement program. The social work field placement is described as a learning experience designed to translate the students' interests, interpersonal abilities, and academic knowledge and theory into the capability of enabling others to solve problems. Expectations of skills to be learned in the…

  20. 25 CFR 26.27 - What kind of Job Placement support services can I expect?

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 25 Indians 1 2014-04-01 2014-04-01 false What kind of Job Placement support services can I expect? 26.27 Section 26.27 Indians BUREAU OF INDIAN AFFAIRS, DEPARTMENT OF THE INTERIOR HUMAN SERVICES JOB PLACEMENT AND TRAINING PROGRAM Job Placement Services § 26.27 What kind of Job Placement support services...

  1. 25 CFR 26.24 - What is the scope of the Job Placement Program?

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 25 Indians 1 2013-04-01 2013-04-01 false What is the scope of the Job Placement Program? 26.24 Section 26.24 Indians BUREAU OF INDIAN AFFAIRS, DEPARTMENT OF THE INTERIOR HUMAN SERVICES JOB PLACEMENT AND TRAINING PROGRAM Job Placement Services § 26.24 What is the scope of the Job Placement Program...

  2. 25 CFR 26.27 - What kind of Job Placement support services can I expect?

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 25 Indians 1 2011-04-01 2011-04-01 false What kind of Job Placement support services can I expect? 26.27 Section 26.27 Indians BUREAU OF INDIAN AFFAIRS, DEPARTMENT OF THE INTERIOR HUMAN SERVICES JOB PLACEMENT AND TRAINING PROGRAM Job Placement Services § 26.27 What kind of Job Placement support services...

  3. 25 CFR 26.24 - What is the scope of the Job Placement Program?

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 25 Indians 1 2011-04-01 2011-04-01 false What is the scope of the Job Placement Program? 26.24 Section 26.24 Indians BUREAU OF INDIAN AFFAIRS, DEPARTMENT OF THE INTERIOR HUMAN SERVICES JOB PLACEMENT AND TRAINING PROGRAM Job Placement Services § 26.24 What is the scope of the Job Placement Program...

  4. 25 CFR 26.27 - What kind of Job Placement support services can I expect?

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 25 Indians 1 2013-04-01 2013-04-01 false What kind of Job Placement support services can I expect? 26.27 Section 26.27 Indians BUREAU OF INDIAN AFFAIRS, DEPARTMENT OF THE INTERIOR HUMAN SERVICES JOB PLACEMENT AND TRAINING PROGRAM Job Placement Services § 26.27 What kind of Job Placement support services...

  5. 25 CFR 26.24 - What is the scope of the Job Placement Program?

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 25 Indians 1 2012-04-01 2011-04-01 true What is the scope of the Job Placement Program? 26.24 Section 26.24 Indians BUREAU OF INDIAN AFFAIRS, DEPARTMENT OF THE INTERIOR HUMAN SERVICES JOB PLACEMENT AND TRAINING PROGRAM Job Placement Services § 26.24 What is the scope of the Job Placement Program...

  6. 25 CFR 26.27 - What kind of Job Placement support services can I expect?

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 25 Indians 1 2012-04-01 2011-04-01 true What kind of Job Placement support services can I expect? 26.27 Section 26.27 Indians BUREAU OF INDIAN AFFAIRS, DEPARTMENT OF THE INTERIOR HUMAN SERVICES JOB PLACEMENT AND TRAINING PROGRAM Job Placement Services § 26.27 What kind of Job Placement support services...

  7. 25 CFR 26.24 - What is the scope of the Job Placement Program?

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 25 Indians 1 2014-04-01 2014-04-01 false What is the scope of the Job Placement Program? 26.24 Section 26.24 Indians BUREAU OF INDIAN AFFAIRS, DEPARTMENT OF THE INTERIOR HUMAN SERVICES JOB PLACEMENT AND TRAINING PROGRAM Job Placement Services § 26.24 What is the scope of the Job Placement Program...

  8. 25 CFR 26.11 - What type of Job Placement and Training assistance may be approved?

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 25 Indians 1 2010-04-01 2010-04-01 false What type of Job Placement and Training assistance may be... JOB PLACEMENT AND TRAINING PROGRAM General Applicability § 26.11 What type of Job Placement and... supplemental assistance that supports job placement or training activities (see subpart B of this part for Job...

  9. 25 CFR 26.8 - Where do I go to apply for Job Placement and Training assistance?

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 25 Indians 1 2010-04-01 2010-04-01 false Where do I go to apply for Job Placement and Training... PLACEMENT AND TRAINING PROGRAM General Applicability § 26.8 Where do I go to apply for Job Placement and Training assistance? You may apply for Job Placement and Training assistance at the servicing office...

  10. 25 CFR 26.3 - What is the purpose of the Job Placement and Training Program?

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 25 Indians 1 2010-04-01 2010-04-01 false What is the purpose of the Job Placement and Training... PLACEMENT AND TRAINING PROGRAM General Applicability § 26.3 What is the purpose of the Job Placement and Training Program? The purpose of the Job Placement and Training Program is to assist eligible applicants to...

  11. Substantial changes in mastery perceptions of dementia caregivers with the placement of a care recipient.

    PubMed

    Infurna, Frank J; Gerstorf, Denis; Zarit, Steven H

    2013-03-01

    The current study examined how a key component of caregiving stress processes, global mastery perceptions, changes with placing the care recipient in a nursing home or institution. We also explored the role of primary stressors in accounting for mastery changes with placement and whether characteristics of the caregiver and care recipient moderate reactions to placement. We applied multiphase growth curve models to prospective longitudinal data from 271 caregivers in the Caregiver Stress and Coping Study who experienced placement of their care recipient. Using a time-to/from-placement metric, we found that caregivers typically experienced declines in mastery preceding placement, followed by a significant increase within 1 year after placement and further increases thereafter. Corresponding changes in primary stressors (role overload) mediated the placement-related increase in mastery. Caregivers who reported more depressive symptoms and activities of daily living/instrumental activities of daily living dependencies of the care recipient were more likely to experience larger placement-related increases in mastery perceptions. Our findings suggest that placement alters psychological resources of caregivers and this effect is driven by corresponding changes in primary stressors. Findings also underscore the importance of examining change processes across salient life events and transitions.

  12. Placement of empty catheters for an HDR-emulating LDR prostate brachytherapy technique: comparison to standard intraoperative planning.

    PubMed

    Niedermayr, Thomas R; Nguyen, Paul L; Murciano-Goroff, Yonina R; Kovtun, Konstantin A; Neubauer Sugar, Emily; Cail, Daniel W; O'Farrell, Desmond A; Hansen, Jorgen L; Cormack, Robert A; Buzurovic, Ivan; Wolfsberger, Luciant T; O'Leary, Michael P; Steele, Graeme S; Devlin, Philip M; Orio, Peter F

    2014-01-01

    We sought to determine whether placing empty catheters within the prostate and then inverse planning iodine-125 seed locations within those catheters (High Dose Rate-Emulating Low Dose Rate Prostate Brachytherapy [HELP] technique) would improve concordance between planned and achieved dosimetry compared with a standard intraoperative technique. We examined 30 consecutive low dose rate prostate cases performed by standard intraoperative technique of planning followed by needle placement/seed deposition and compared them to 30 consecutive low dose rate prostate cases performed by the HELP technique. The primary endpoint was concordance between planned percentage of the clinical target volume that receives at least 100% of the prescribed dose/dose that covers 90% of the volume of the clinical target volume (V100/D90) and the actual V100/D90 achieved at Postoperative Day 1. The HELP technique had superior concordance between the planned target dosimetry and what was actually achieved at Day 1 and Day 30. Specifically, target D90 at Day 1 was on average 33.7 Gy less than planned for the standard intraoperative technique but was only 10.5 Gy less than planned for the HELP technique (p < 0.001). Day 30 values were 16.6 Gy less vs. 2.2 Gy more than planned, respectively (p = 0.028). Day 1 target V100 was 6.3% less than planned with standard vs. 2.8% less for HELP (p < 0.001). There was no significant difference between the urethral and rectal concordance (all p > 0.05). Placing empty needles first and optimizing the plan to the known positions of the needles resulted in improved concordance between the planned and the achieved dosimetry to the target, possibly because of elimination of errors in needle placement. Copyright © 2014 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  13. Metal artifact reduction by filter-based dual-energy cone-beam computed tomography on a bench-top micro-CBCT system: concept and demonstration.

    PubMed

    Iramina, Hiraku; Hamaguchi, Takumi; Nakamura, Mitsuhiro; Mizowaki, Takashi; Kanno, Ikuo

    2018-04-30

    We evaluated two dual-energy cone-beam computed tomography (DE-CBCT) methodologies for a bench-top micro-CBCT system to reduce metal artifacts on reconstructed images. Two filter-based DE-CBCT methodologies were tested: (i) alternative spectral switching and (ii) simultaneous beam splitting. We employed filters of 0.6-mm-thick tin and 0.1-mm-thick tungsten to generate high- and low-energy spectra from 120 kVp X-rays, respectively. The spectral switching method was imitated by two half scans with different filters (pseudo-switching). Filters were placed and between the X-ray tube and a phantom ('1-u,' '2-u'), a phantom and a flat panel detector ('1-d,' '2-d'), and compared with (iii) two half scans at 80 and 140 kVp [pseudo-(80,140)]. For the splitting method, two half-width filters were aligned along a rotating axis. Projections were separated into halves and merged with corresponding areas of opposed projections after one full rotation. A solid 30-mm-diameter acrylic phantom and an acrylic phantom with four 5-mm-diameter titanium rods were used. DE images were generated by weighted summation of the high- and low-energy images. The blending factor was changed from 0 to +5 in increments of 0.01. Relative errors (REs) of the linear attenuation coefficients of the two phantoms and the contrast-to-noise ratios (CNRs) between the titanium and acrylic regions were compared. All methods showed zero REs except for the method (2-d). CNRs for pseudo-switching with upstream placement were 1.4-fold larger than CNRs for the pseudo-(80,140) method. CNRs for the downstream placements were small. It was concluded that the pseudo-switching method with upstream placement is appropriate for reducing metal artifacts.

  14. Patterns of out-of-home placement decision-making in child welfare.

    PubMed

    Chor, Ka Ho Brian; McClelland, Gary M; Weiner, Dana A; Jordan, Neil; Lyons, John S

    2013-10-01

    Out-of-home placement decision-making in child welfare is founded on the best interest of the child in the least restrictive setting. After a child is removed from home, however, little is known about the mechanism of placement decision-making. This study aims to systematically examine the patterns of out-of-home placement decisions made in a state's child welfare system by comparing two models of placement decision-making: a multidisciplinary team decision-making model and a clinically based decision support algorithm. Based on records of 7816 placement decisions representing 6096 children over a 4-year period, hierarchical log-linear modeling characterized concordance or agreement, and discordance or disagreement when comparing the two models and accounting for age-appropriate placement options. Children aged below 16 had an overall concordance rate of 55.7%, most apparent in the least restrictive (20.4%) and the most restrictive placement (18.4%). Older youth showed greater discordant distributions (62.9%). Log-linear analysis confirmed the overall robustness of concordance (odd ratios [ORs] range: 2.9-442.0), though discordance was most evident from small deviations from the decision support algorithm, such as one-level under-placement in group home (OR=5.3) and one-level over-placement in residential treatment center (OR=4.8). Concordance should be further explored using child-level clinical and placement stability outcomes. Discordance might be explained by dynamic factors such as availability of placements, caregiver preferences, or policy changes and could be justified by positive child-level outcomes. Empirical placement decision-making is critical to a child's journey in child welfare and should be continuously improved to effect positive child welfare outcomes. Copyright © 2013 Elsevier Ltd. All rights reserved.

  15. The process and challenges of obtaining and sustaining clinical placements for nursing and allied health students.

    PubMed

    Taylor, Christine; Angel, Liz; Nyanga, Lucy; Dickson, Cathy

    2017-10-01

    To describe the process and challenges from a project that aimed to develop processes, source new placements and place students primarily in the discipline of nursing, but also occupational therapy, physiotherapy, podiatry, social work, and speech therapy. Clinical experience in health facilities is an essential element of health professional education, yet globally, there is a lack of clinical placements to meet demands. Educational providers are seeking placements in nontraditional facilities, yet little has been reported on the challenges in the process of procuring clinical placements. The project used a descriptive approach within a quality implementation framework. The project was guided by the quality implementation framework that included four critical steps: considerations of the host setting, structuring the implementation, supporting the implementation and improving future applications. A total of 115 new student placements were finalised across six health disciplines, including elderly care, nongovernment organisations and general practice. Sixty-two nursing students were placed in the new placements during the project. Challenges included communication, the time-consuming nature of the process and 'gatekeeping' blocks to obtaining placements. Recommendations included the importance of personal interaction in developing and maintaining relationships, and the need for clear communication processes and documentation. Potential areas for research are also given. There is great potential for growth in establishing new placements outside the traditional placement facilities for nursing and allied health and for expanding already existing nonhospital placements. Clinical professional experiences are essential to any nursing or allied health programme. There is an increasing demand for, and global lack of, clinical placements for nursing and allied health students. The results provide nursing and allied health educators and managers a framework for planning clinical placement procurement, and assisting in decision-making and developing strategies and processes for practice. © 2016 John Wiley & Sons Ltd.

  16. Occupational therapy students' contribution to occasions of service during practice placements in health settings.

    PubMed

    Rodger, Sylvia; Stephens, Elizabeth; Clark, Michele; Ash, Susan; Graves, Nicholas

    2011-12-01

    Currently in the Australian higher education sector, the productivity benefits of occupational therapy clinical education placements are a contested issue. This article will report results of a study that developed a methodology for documenting time use during placements and investigated the productivity changes associated with occupational therapy clinical education placements in Queensland, Australia. Supervisors' and students' time use during placements and how this changed for supervisors compared to pre- and post-placement is also presented. Using a cohort survey design, participants were students from two Queensland universities, and their supervisors employed by Queensland Health. Time use was recorded in 30 minute blocks according to particular categories. There was a significant increase in supervisors' time spent in patient care activities (F = 94.011(2,12.37 df) , P < 0.001) between pre- and during placement (P < 0.001) and decrease between during and post-placement (P < 0.001). Supervisors' time spent in all non-patient care activities was also significant (F = 4.580(2,16 df) , P = 0.027) increasing between pre- and during placement (P = 0.028). There was a significant decrease in supervisors' time spent in placement activities (F = 5.133(2,19.18 df) , P = 0.016) from during to post-placement. Students spent more time than supervisors in patient care activities while on placement. A novel method for reporting productivity and time-use changes during clinical education programs for occupational therapy has been applied. Supervisors spent considerable time in assessing and managing students and their clinical education role should be seen as core business in standard occupational therapy practice. This paper will contribute to future assessments of the economic impact of student placements for allied health disciplines. © 2011 The Authors. Australian Occupational Therapy Journal © 2011 Occupational Therapy Australia.

  17. Endpoint Accuracy in Manual Control of a Steerable Needle.

    PubMed

    van de Berg, Nick J; Dankelman, Jenny; van den Dobbelsteen, John J

    2017-02-01

    To study the ability of a human operator to manually correct for errors in the needle insertion path without partial withdrawal of the needle by means of an active, tip-articulated steerable needle. The needle is composed of a 1.32-mm outer-diameter cannula, with a flexure joint near the tip, and a retractable stylet. The bending stiffness of the needle resembles that of a 20-gauge hypodermic needle. The needle functionality was evaluated in manual insertions by steering to predefined targets and a lateral displacement of 20 mm from the straight insertion line. Steering tasks were conducted in 5 directions and 2 tissue simulants under image guidance from a camera. The repeatability in instrument actuations was assessed during 100 mm deep automated insertions with a linear motor. In addition to tip position, tip angles were tracked during the insertions. The targeting error (mean absolute error ± standard deviation) during manual steering to 5 different targets in stiff tissue was 0.5 mm ± 1.1. This variability in manual tip placement (1.1 mm) was less than the variability among automated insertions (1.4 mm) in the same tissue type. An increased tissue stiffness resulted in an increased lateral tip displacement. The tip angle was directly controlled by the user interface, and remained unaffected by the tissue stiffness. This study demonstrates the ability to manually steer needles to predefined target locations under image guidance. Copyright © 2016 SIR. Published by Elsevier Inc. All rights reserved.

  18. Skull Defects in Finite Element Head Models for Source Reconstruction from Magnetoencephalography Signals

    PubMed Central

    Lau, Stephan; Güllmar, Daniel; Flemming, Lars; Grayden, David B.; Cook, Mark J.; Wolters, Carsten H.; Haueisen, Jens

    2016-01-01

    Magnetoencephalography (MEG) signals are influenced by skull defects. However, there is a lack of evidence of this influence during source reconstruction. Our objectives are to characterize errors in source reconstruction from MEG signals due to ignoring skull defects and to assess the ability of an exact finite element head model to eliminate such errors. A detailed finite element model of the head of a rabbit used in a physical experiment was constructed from magnetic resonance and co-registered computer tomography imaging that differentiated nine tissue types. Sources of the MEG measurements above intact skull and above skull defects respectively were reconstructed using a finite element model with the intact skull and one incorporating the skull defects. The forward simulation of the MEG signals reproduced the experimentally observed characteristic magnitude and topography changes due to skull defects. Sources reconstructed from measured MEG signals above intact skull matched the known physical locations and orientations. Ignoring skull defects in the head model during reconstruction displaced sources under a skull defect away from that defect. Sources next to a defect were reoriented. When skull defects, with their physical conductivity, were incorporated in the head model, the location and orientation errors were mostly eliminated. The conductivity of the skull defect material non-uniformly modulated the influence on MEG signals. We propose concrete guidelines for taking into account conducting skull defects during MEG coil placement and modeling. Exact finite element head models can improve localization of brain function, specifically after surgery. PMID:27092044

  19. Alternate row placement is ineffective for cultural control of Meloidogyne incognita in cotton

    PubMed Central

    2008-01-01

    The objective of this study was to determine if planting cotton into the space between the previous year's rows reduces crop loss due to Meloidogyne incognita compared to planting in the same row every year. Row placement had a significant (P ≤ 0.05) effect on nematode population levels only on 8 July 2005. Plots receiving 1,3-dichloropropene plus aldicarb had lower nematode population levels than non-fumigated plots on 24 May and 8 July in 2005, but not in 2004. The effect of nematicide treatment on nematode populations was not affected by row placement. Row placement did not have a significant effect on root galling or yield in 2004 or 2005. Nematicide treatment decreased root galling in all years, and the decrease was not influenced by row placement. Yield was increased by nematicide application in 2004 and 2005, and the increase was not affected by row placement. Percentage yield loss was not affected by row placement. Changing the placement of rows reduced nematode population levels only on one sampling date in one year, but end-of-season root galling and lint yield were not affected by changing the placement of rows, nor was the effect of fumigation on yield influenced by row placement. Therefore, row placement is unlikely to contribute to M. incognita management in cotton. PMID:19440259

  20. The Effect of Product Placement Marketing on Effectiveness of Internet Advertising

    NASA Astrophysics Data System (ADS)

    Liao, Hsiu-Li; Liu, Su-Houn; Pi, Shih-Ming; Chen, Hui-Ju

    Compared to the traditional way of doing advertising, such as ad Banners, internet product placement is now emerging as a promising strategy for advertisers to do their job effectively in this Web 2.0 era. Therefore, this study focuses on the effectiveness of product placement advertising on the Internet. The results show that product prominence (Subtle or Prominent) and presentation of the advertising (Video or Images) significantly impacts the effectiveness of product placement advertising on the Internet, including brand impression, advertising attitude, and intention to click. Product prominence and presentation of the advertisement have an interactive impact. Our findings indicated that presenting the product through videos will enhance higher levels of advertising attitude, brand impression, and intention to click than presenting it through still images. Subtle placements will increase the level of advertising attitude and intention to click more so than prominent placements. But prominent placements increase the brand impression more than the subtle placements.

  1. Humanitarian engineering placements in our own communities

    NASA Astrophysics Data System (ADS)

    VanderSteen, J. D. J.; Hall, K. R.; Baillie, C. A.

    2010-05-01

    There is an increasing interest in the humanitarian engineering curriculum, and a service-learning placement could be an important component of such a curriculum. International placements offer some important pedagogical advantages, but also have some practical and ethical limitations. Local community-based placements have the potential to be transformative for both the student and the community, although this potential is not always seen. In order to investigate the role of local placements, qualitative research interviews were conducted. Thirty-two semi-structured research interviews were conducted and analysed, resulting in a distinct outcome space. It is concluded that local humanitarian engineering placements greatly complement international placements and are strongly recommended if international placements are conducted. More importantly it is seen that we are better suited to address the marginalised in our own community, although it is often easier to see the needs of an outside populace.

  2. Application of coordinate transform on ball plate calibration

    NASA Astrophysics Data System (ADS)

    Wei, Hengzheng; Wang, Weinong; Ren, Guoying; Pei, Limei

    2015-02-01

    For the ball plate calibration method with coordinate measurement machine (CMM) equipped with laser interferometer, it is essential to adjust the ball plate parallel to the direction of laser beam. It is very time-consuming. To solve this problem, a method based on coordinate transformation between machine system and object system is presented. With the fixed points' coordinates of the ball plate measured in the object system and machine system, the transformation matrix between the coordinate systems is calculated. The laser interferometer measurement data error due to the placement of ball plate can be corrected with this transformation matrix. Experimental results indicate that this method is consistent with the handy adjustment method. It avoids the complexity of ball plate adjustment. It also can be applied to the ball beam calibration.

  3. SPOT-A SENSOR PLACEMENT OPTIMIZATION TOOL FOR ...

    EPA Pesticide Factsheets

    journal article This paper presents SPOT, a Sensor Placement Optimization Tool. SPOT provides a toolkit that facilitates research in sensor placement optimization and enables the practical application of sensor placement solvers to real-world CWS design applications. This paper provides an overview of SPOT’s key features, and then illustrates how this tool can be flexibly applied to solve a variety of different types of sensor placement problems.

  4. Immediate placement of endosseous implants into the extraction sockets.

    PubMed

    Ebenezer, Vijay; Balakrishnan, K; Asir, R Vigil Dev; Sragunar, Banu

    2015-04-01

    Implant by definition "means any object or material, such as an alloplastic substance or other tissue, which is partial or completely inserted into the body for therapeutic, diagnostic, prosthetic, or experimental purpose." The placement of a dental implant in an extraction socket at the time of extraction or explantation is known as immediate implant placement whereas delayed placement of implant signifies the implant placement in edentulous areas where healing has completed with new bone formation after the loss of tooth/teeth. Recent idea goes by "why late when it can be done immediately." There are several advantages of immediate placement of implants, and lots of studies have been done. In this article, the advantages and disadvantages of immediate versus delayed placement of implants have been reviewed.

  5. This is Advertising! Effects of Disclosing Television Brand Placement on Adolescents.

    PubMed

    van Reijmersdal, Eva A; Boerman, Sophie C; Buijzen, Moniek; Rozendaal, Esther

    2017-02-01

    As heavy media users, adolescents are frequently exposed to embedded advertising formats such as brand placements. Because this may lead to unwitting persuasion, regulations prescribe disclosure of brand placements. This study aimed to increase our understanding of the effects of disclosing television brand placements and disclosure duration on adolescents' persuasion knowledge (i.e., recognition of brand placement as being advertising, understanding that brand placement has a persuasive intent and critical attitude toward brand placement) and brand responses (i.e., brand memory and brand attitude). To do so, an earlier study that was conducted among adults was replicated among adolescents aged 13-17 years (N = 221, 44 % female). The present study shows that brand placement disclosure had limited effects on adolescents' persuasion knowledge as it only affected adolescents' understanding of persuasive intent, did not mitigate persuasion, but did increase brand memory. These findings suggest that brand placement disclosure has fundamentally different effects on adolescents than on adults: the disclosures had less effects on activating persuasion knowledge and mitigating persuasion among adolescents than among adults. Implications for advertising disclosure regulation and consequences for advertisers are discussed.

  6. Dental hygiene student experiences in external placements in Australia.

    PubMed

    Taylor, Jane A; Hayes, Melanie J; Wallace, Linda

    2012-05-01

    While placements in external locations are being increasingly used in dental education globally, few studies have explored the student learning experience at such placements. The purpose of this study was to investigate student experiences while on external placement in a baccalaureate dental hygiene program. A self-reporting questionnaire was distributed to final-year dental hygiene students (n=77) at the University of Newcastle, Australia, in 2010. The questionnaire included questions regarding the type of placement, experiences offered, supervision, resources available, and lasting impressions. Responding students were generally positive about their external placement experience and indicated that the majority of facilities provided them with the opportunity to provide direct patient care and perform clinical tasks typical of a practicing hygienist. However, there was a statistically significant difference in their opinions about discipline-focused and community placements. Students indicated that their external placement experience provided opportunities to learn more about time and patient management, including hands-on experience with specific clinical tasks. Ongoing evaluations are necessary to ensure that external placements meet both student needs and intended learning outcomes within dental hygiene programs.

  7. [Eleven Patients with Gastric Cancer Who Received Chemotherapy after Stent Placement for Gastric Outlet Obstruction].

    PubMed

    Endo, Shunji; Nakagawa, Tomo; Konishi, Ken; Ikenaga, Masakazu; Ohta, Katsuya; Nakashima, Shinsuke; Matsumoto, Kenichi; Nishikawa, Kazuhiro; Ohmori, Takeshi; Yamada, Terumasa

    2017-01-01

    Endoscopic placement of self-expandable metallic stents is reportedly effective for gastric outlet obstructions due to advanced gastric cancer, and is less invasive than gastrojejunostomy. For patients who have good performance status, we administer chemotherapy after stent placement, although the safety and feasibility of this chemotherapy have not yet been discussed in full. Between 2011 and 2015, 15 patients at our institution underwent endoscopic gastroduodenal stent placement for gastric outlet obstruction due to gastric cancer. Eleven of these patients were administered chemotherapy after stent placement. In our case series, we did not observe any specific adverse event caused by stent placement plus chemotherapy. Adverse events after chemotherapy included anemia of CTCAE Grade 3 in 7 patients. Stent-in-stent placement was needed in 2 patients. Neither stent migration nor perforation was observed. Therefore, chemotherapy after stent placement for gastric outlet obstruction due to gastric cancer was considered safe and feasible. Stent placement is useful not only as palliative care for patients with terminal-stage disease, but also as one of the multimodal therapeutic strategies for gastric cancer.

  8. Effectiveness and cost-effectiveness of embedded simulation in occupational therapy clinical practice education: study protocol for a randomised controlled trial.

    PubMed

    Imms, Christine; Chu, Eli Mang Yee; Guinea, Stephen; Sheppard, Loretta; Froude, Elspeth; Carter, Rob; Darzins, Susan; Ashby, Samantha; Gilbert-Hunt, Susan; Gribble, Nigel; Nicola-Richmond, Kelli; Penman, Merrolee; Gospodarevskaya, Elena; Mathieu, Erin; Symmons, Mark

    2017-07-21

    Clinical placements are a critical component of the training for health professionals such as occupational therapists. However, with growing student enrolments in professional education courses and workload pressures on practitioners, it is increasingly difficult to find sufficient, suitable placements that satisfy program accreditation requirements. The professional accrediting body for occupational therapy in Australia allows up to 200 of the mandatory 1000 clinical placement hours to be completed via simulation activities, but evidence of effectiveness and efficiency for student learning outcomes is lacking. Increasingly placement providers charge a fee to host students, leading educators to consider whether providing an internal program might be a feasible alternative for a portion of placement hours. Economic analysis of the incremental costs and benefits of providing a traditional versus simulated placement is required to inform decision-making. This study is a pragmatic, non-inferiority, single-blind, multicentre, two-group randomised controlled trial (RCT) with an embedded economic analysis. The RCT will compare a block of 40 hours of simulated placement (intervention) with a 40-hour block of traditional placement (comparator), with a focus on student learning outcomes and delivery costs. Six universities will instigate the educational intervention within their respective occupational therapy courses, randomly assigning their cohort of students (1:1 allocation) to the simulated or traditional clinical placements. The primary outcome is achievement of professional behaviours (e.g. communication, clinical reasoning) as assessed by a post-placement written examination. Secondary outcomes include proportions passing the placement assessed using the Student Practice Evaluation Form-Revised, changes in student confidence pre-/post-placement, student and educator evaluation of the placement experience and cost-effectiveness of simulated versus traditional clinical placements. Comprehensive cost data will be collected for both the simulated and traditional placement programs at each site for economic evaluation. Use of simulation in health-related fields like occupational therapy is common, but these activities usually relate to brief opportunities for isolated skill development. The simulated clinical placement evaluated in this trial is less common because it encapsulates a 5-day block of integrated activities, designed and delivered in a manner intended to emulate best-practice placement experiences. The planned study is rare due to inclusion of an economic analysis that aims to provide valuable information about the relationship between costs and outcomes across participating sites. Australian New Zealand Clinical Trials Registry, ACTRN12616001339448 . Registered 26 September 2016.

  9. Payment of Advanced Placement Exam Fees by Virginia Public School Divisions and Its Impact on Advanced Placement Enrollment and Scores

    ERIC Educational Resources Information Center

    Cirillo, Mary Grupe

    2010-01-01

    The purpose of this study was to determine the impact of Virginia school divisions' policy of paying the fee for students to take Advanced Placement exams on Advanced Placement course enrollment, the number of Advanced Placement exams taken by students, the average scores earned and the percent of students earning qualifying scores of 3, 4, or 5…

  10. WAMA: a method of optimizing reticle/die placement to increase litho cell productivity

    NASA Astrophysics Data System (ADS)

    Dor, Amos; Schwarz, Yoram

    2005-05-01

    This paper focuses on reticle/field placement methodology issues, the disadvantages of typical methods used in the industry, and the innovative way that the WAMA software solution achieves optimized placement. Typical wafer placement methodologies used in the semiconductor industry considers a very limited number of parameters, like placing the maximum amount of die on the wafer circle and manually modifying die placement to minimize edge yield degradation. This paper describes how WAMA software takes into account process characteristics, manufacturing constraints and business objectives to optimize placement for maximum stepper productivity and maximum good die (yield) on the wafer.

  11. Substantial Changes in Mastery Perceptions of Dementia Caregivers With the Placement of a Care Recipient

    PubMed Central

    2013-01-01

    Objectives. The current study examined how a key component of caregiving stress processes, global mastery perceptions, changes with placing the care recipient in a nursing home or institution. We also explored the role of primary stressors in accounting for mastery changes with placement and whether characteristics of the caregiver and care recipient moderate reactions to placement. Method. We applied multiphase growth curve models to prospective longitudinal data from 271 caregivers in the Caregiver Stress and Coping Study who experienced placement of their care recipient. Results. Using a time-to/from-placement metric, we found that caregivers typically experienced declines in mastery preceding placement, followed by a significant increase within 1 year after placement and further increases thereafter. Corresponding changes in primary stressors (role overload) mediated the placement-related increase in mastery. Caregivers who reported more depressive symptoms and activities of daily living/instrumental activities of daily living dependencies of the care recipient were more likely to experience larger placement-related increases in mastery perceptions. Discussion. Our findings suggest that placement alters psychological resources of caregivers and this effect is driven by corresponding changes in primary stressors. Findings also underscore the importance of examining change processes across salient life events and transitions. PMID:22956053

  12. Clinical placements in general practice: relationships between practice nurses and tertiary institutions.

    PubMed

    Peters, Kathleen; Halcomb, Elizabeth J; McInnes, Susan

    2013-05-01

    As a practice-based discipline a key component of undergraduate nurse education is clinical practice experience. The quality of clinical experiences has a significant impact on the students' ability to function competently post graduation. The relationship between higher education institutions (HEIs) and health service placement providers impacts upon the quality of clinical placements. In Australia, the growth of primary care nursing and the shortage of acute clinical places has prompted HEIs to explore the placement of students in general practice. Given the increasing attention being paid to non-traditional clinical placements, it is timely to explore how universities are establishing relationships and models of clinical placement. This paper uses qualitative research methods to explore the perspectives of 12 Australian general practice nurses who have experience in facilitating undergraduate clinical placements about the relationships between HEIs and nurses. Findings are presented in the following three themes: (1) Appropriate preparation for placement: They don't know what primary health really means, (2) Seeking greater consultation in the organisation of clinical placements: they've got to do it one way for everyone, and (3) Uncertainty and lack of support: I had no contact with the university. Clinical placements in general practice can be an innovative strategy providing non-traditional, yet high quality, teaching and learning experiences for undergraduate nursing students. To optimise the quality of these placements, however, it is essential that HEIs provide appropriate support to the practice nurses mentoring these students. Copyright © 2012 Elsevier Ltd. All rights reserved.

  13. Infant sleep positioning by nursery staff and mothers in newborn hospital nurseries.

    PubMed

    Stastny, Penny F; Ichinose, Travers Y; Thayer, Sharon D; Olson, Robert J; Keens, Thomas G

    2004-01-01

    Although advice from healthcare professionals may influence parental infant placement choice to reduce sudden infant death syndrome risk, literature on nursery staff infant placement behaviors and the degree to which they influence maternal infant sleep positioning is limited. To assess newborn placement practices of the mother and nursery staff and their interrelationship in the hospital setting. A cross-sectional survey-based study was conducted among hospital newborn nursery staff (n = 96) and mothers of newborns (n = 579) at eight perinatal hospitals in Orange County, California. Although a majority of sampled nursery staff (72%) identified the supine position as the placement that most lowers sudden infant death syndrome risk, only 30% reported most often placing infants to sleep in that position, with most staff (91%) citing fear of aspiration as the motivation for supine position avoidance. Only 34% of staff reported advising exclusive supine infant positioning to mothers. Approximately 36% of mothers reported using supine infant placement exclusively. Maternal infant placement choice varied by both the advice (p <.01) and the placement modeling (p <.01) provided by staff, with the highest proportion of usual supine infant placement found among mothers who reported receiving both. A mother's race/ethnicity also affected the reception of exclusive supine placement recommendations (p <.01). Exclusive supine infant placement appears to be underused by both nursery staff and mothers of newborn infants. Culturally grounded educational intervention with nursery staff regarding infant positioning and placement in the hospital setting is indicated.

  14. Immediate placement of endosseous implants into the extraction sockets

    PubMed Central

    Ebenezer, Vijay; Balakrishnan, K.; Asir, R. Vigil Dev; Sragunar, Banu

    2015-01-01

    Implant by definition “means any object or material, such as an alloplastic substance or other tissue, which is partial or completely inserted into the body for therapeutic, diagnostic, prosthetic, or experimental purpose.” The placement of a dental implant in an extraction socket at the time of extraction or explantation is known as immediate implant placement whereas delayed placement of implant signifies the implant placement in edentulous areas where healing has completed with new bone formation after the loss of tooth/teeth. Recent idea goes by “why late when it can be done immediately.” There are several advantages of immediate placement of implants, and lots of studies have been done. In this article, the advantages and disadvantages of immediate versus delayed placement of implants have been reviewed. PMID:26015721

  15. Wafer-level colinearity monitoring for TFH applications

    NASA Astrophysics Data System (ADS)

    Moore, Patrick; Newman, Gary; Abreau, Kelly J.

    2000-06-01

    Advances in thin film head (TFH) designs continue to outpace those in the IC industry. The transition to giant magneto resistive (GMR) designs is underway along with the push toward areal densities in the 20 Gbit/inch2 regime and beyond. This comes at a time when the popularity of the low-cost personal computer (PC) is extremely high, and PC prices are continuing to fall. Consequently, TFH manufacturers are forced to deal with pricing pressure in addition to technological demands. New methods of monitoring and improving yield are required along with advanced head designs. TFH manufacturing is a two-step process. The first is a wafer-level process consisting of manufacturing devices on substrates using processes similar to those in the IC industry. The second half is a slider-level process where wafers are diced into 'rowbars' containing many heads. Each rowbar is then lapped to obtain the desired performance from each head. Variation in the placement of specific layers of each device on the bar, known as a colinearity error, causes a change in device performance and directly impacts yield. The photolithography tool and process contribute to colinearity errors. These components include stepper lens distortion errors, stepper stage errors, reticle fabrication errors, and CD uniformity errors. Currently, colinearity is only very roughly estimated during wafer-level TFH production. An absolute metrology tool, such as a Nikon XY, could be used to quantify colinearity with improved accuracy, but this technique is impractical since TFH manufacturers typically do not have this type of equipment at the production site. More importantly, this measurement technique does not provide the rapid feedback needed in a high-volume production facility. Consequently, the wafer-fab must rely on resistivity-based measurements from slider-fab to quantify colinearity errors. The feedback of this data may require several weeks, making it useless as a process diagnostic. This study examines a method of quickly estimating colinearity at the wafer-level with a test reticle and metrology equipment routinely found in TFH facilities. Colinearity results are correlated to slider-fab measurements on production devices. Stepper contributions to colinearity are estimated, and compared across multiple steppers and stepper generations. Multiple techniques of integrating this diagnostic into production are investigated and discussed.

  16. Understanding the Influence of Mental Health Diagnosis and Gender on Placement Decisions for Justice-Involved Youth.

    PubMed

    Kempker, Samantha M; Schmidt, Adam T; Espinosa, Erin M

    2017-07-01

    Justice-involved youth have high rates of psychiatric diagnoses, and these youth are often placed out-of-home, although evidence identifies several negative implications of juvenile confinement, especially for youth with psychopathology. Furthermore, youth in the justice system may be processed differently based on gender. As males and females tend to manifest symptoms differently, the psychopathology of youth may act to moderate the relationship between gender and placement in the juvenile justice system. The present study used a large, diverse sample (n = 9 851, 19.8 % female) to examine whether youth placed in various types of out-of-home facilities differed in terms of externalizing, internalizing, substance use, or comorbid disorders, and to determine the predictive value of mental health diagnoses in placement decisions. The moderation effect of psychopathology and substance use on the relationship between gender and placement also was explored. The results indicated that each type of disorder differed across placements, with internalizing being most prevalent in non-secure, and externalizing, comorbid, and substance use being most prevalent in secure settings. Mental health diagnoses improved the prediction of placement in each out-of-home placement beyond legal and demographic factors such that externalizing and substance use disorders decreased the likelihood of placement in non-secure settings, and internalizing, externalizing, and substance use disorders increased the likelihood of placement in secure and state-secure facilities. The relationship between internalizing pathology and placement in more secure facilities was moderated by externalizing pathology. The relationship between gender and placement was significantly moderated by mental health such that females with mental health diagnoses receive less secure placements. Implications for policymakers and practitioners are discussed, as well as implications for reforming juvenile justice within a developmental approach.

  17. Ketorolac for Pain Control With Intrauterine Device Placement: A Randomized Controlled Trial

    PubMed Central

    Ngo, Lynn L.; Ward, Kristy K.; Mody, Sheila K.

    2015-01-01

    Objective To evaluate intramuscular ketorolac compared to placebo saline injection for pain control with intrauterine device (IUD) placement. Methods We conducted a randomized, double-blind, placebo controlled trial between July 2012 and March 2014. Patients received ketorolac 30mg or placebo saline intramuscular injection 30 minutes prior to IUD placement. The primary outcome was pain with IUD placement on a 10cm visual analog scale (VAS). Sample size was calculated to provide 80% power to show a 2.0cm difference (α=0.05) in the primary outcome. Secondary outcomes included pain with study drug injection, speculum insertion, tenaculum placement, uterine sounding, and at 5 and 15 minutes after IUD placement. Results A total of 67 women participated in the study, 33 in the ketorolac arm and 34 in the placebo arm. There were no differences in baseline demographics including age, BMI, and race. There were no differences in median pain scores for IUD placement in the placebo versus ketorolac groups (5.2cm vs 3.6cm, p=0.99). There was a decrease in median pain scores at 5 minutes (2.2cm vs 0.3cm, p=<0.001) and 15 minutes (1.6cm vs 0.1cm, p=<0.001) after IUD placement but no difference for all other time points. Nulliparous participants (n=16, 8 per arm) had a decrease in pain scores with IUD placement (8.1cm vs 5.4cm, p=0.02). In this study, 22% of participants in the placebo group and 18% in the ketorolac group reported injection pain was as painful as IUD placement. Conclusions Ketorolac does not reduce pain with IUD placement but does reduce pain at 5 and 15 minutes after placement. PMID:26241253

  18. Ketorolac for Pain Control With Intrauterine Device Placement: A Randomized Controlled Trial.

    PubMed

    Ngo, Lynn L; Ward, Kristy K; Mody, Sheila K

    2015-07-01

    To evaluate intramuscular ketorolac compared with placebo saline injection for pain control with intrauterine device (IUD) placement. We conducted a randomized, double-blind, placebo-controlled trial between July 2012 and March 2014. Patients received 30 mg ketorolac or placebo saline intramuscular injection 30 minutes before IUD placement. The primary outcome was pain with IUD placement on a 10-cm visual analog scale. Sample size was calculated to provide 80% power to show a 2.0-cm difference (α=0.05) in the primary outcome. Secondary outcomes included pain with study drug injection, speculum insertion, tenaculum placement, uterine sounding, and at 5 and 15 minutes after IUD placement. A total of 67 women participated in the study, 33 in the ketorolac arm and 34 in the placebo arm. There were no differences in baseline demographics including age, body mass index, and race. There were no differences in median pain scores for IUD placement in the placebo compared with ketorolac groups (5.2 compared with 3.6 cm, P=.99). There was a decrease in median pain scores at 5 minutes (2.2 compared with 0.3 cm, P≤.001) and 15 minutes (1.6 compared with 0.1 cm, P≤.001) after IUD placement but no difference for all other time points. Nulliparous participants (n=16, eight per arm) had a decrease in pain scores with IUD placement (8.1 compared with 5.4 cm, P=.02). In this study, 22% of participants in the placebo group and 18% in the ketorolac group reported injection pain was as painful as IUD placement. Ketorolac does not reduce pain with IUD placement but does reduce pain at 5 and 15 minutes after placement. ClinicalTrials.gov; www.clinicaltrials.gov, NCT01664559. I.

  19. 5 CFR 9901.516 - Internal placement.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 5 Administrative Personnel 3 2010-01-01 2010-01-01 false Internal placement. 9901.516 Section 9901... PERSONNEL SYSTEM (NSPS) Staffing and Employment External Recruitment and Internal Placement § 9901.516 Internal placement. (a) Determining levels of work and movement within and across career groups. The...

  20. A Case Study Approach to Nursing Home Placement: Smooth and Difficult Cases and Implications for Nursing.

    PubMed

    Koplow, Sarah M; Gallo, Agatha M; Knafl, Kathleen A; Vincent, Catherine; Paun, Olimpia; Gruss, Valerie

    2015-07-01

    Nursing home placement is one of the most challenging aspects of the caregiving journey. A case study approach was used to understand the experiences of caregivers during the first few months following nursing home placement. Two caregivers were selected from a larger qualitative descriptive study because their experiences exemplified smooth and difficult transitions for both themselves and their older family member. The caregivers were interviewed shortly after placement and 3 months post-placement. Four major contextual issues were identified that indicated the similarities and differences between the two cases, including (a) the caregiver's relationship with the older adult during the home caregiving time and post nursing home placement, (b) the circumstances surrounding placement, (c) support systems, and (d) continued involvement in care post-placement. Nursing home staff who understand these issues and address concerns through family-centered care can ease the transition and promote successful collaborations between staff and families. Copyright 2015, SLACK Incorporated.

  1. Strategies for Controlled Placement of Nanoscale Building Blocks

    PubMed Central

    2007-01-01

    The capability of placing individual nanoscale building blocks on exact substrate locations in a controlled manner is one of the key requirements to realize future electronic, optical, and magnetic devices and sensors that are composed of such blocks. This article reviews some important advances in the strategies for controlled placement of nanoscale building blocks. In particular, we will overview template assisted placement that utilizes physical, molecular, or electrostatic templates, DNA-programmed assembly, placement using dielectrophoresis, approaches for non-close-packed assembly of spherical particles, and recent development of focused placement schemes including electrostatic funneling, focused placement via molecular gradient patterns, electrodynamic focusing of charged aerosols, and others. PMID:21794185

  2. Placement shift, sibling relationship quality, and child outcomes in foster care: a controlled study.

    PubMed

    Linares, L Oriana; Li, MiMin; Shrout, Patrick E; Brody, Gene H; Pettit, Gregory S

    2007-12-01

    Sibling unity during family transitions is considered a protective factor for child behavior problems, but there is little empirical support for the widespread child protection policy of placing siblings together in foster care. In a prospective study of 156 maltreated children, siblings were classified in 1 of 3 placement groups: continuously together (n = 110), continuously apart (n = 22), and disrupted placement (siblings placed together were separated; n = 24). Changes in child adjustment as a function of sibling relationship and placement group were examined. Sibling positivity predicted lower child problems at follow-up (about 14 months later), while sibling negativity predicted higher child problems. Placement group did not affect child behavior problems at follow-up; however, compared to siblings in continuous placement (either together or apart), siblings in disrupted placement with high initial behavior problems were rated as having fewer problems at follow-up, while siblings in disrupted placement with low initial behavior problems were rated as having more problems at follow-up. These findings highlight the importance of considering relationships between siblings and the risk that one poses to another before early placement decisions are made.

  3. Organizational and individual factors associated with breakdown of residential placements for people with intellectual disabilities.

    PubMed

    Broadhurst, S; Mansell, J

    2007-04-01

    People with intellectual disabilities (IDs) whose behaviour challenges services are at increased risk of placement breakdown. Most previous research has tended to focus on the role of individual characteristics in predicting breakdown. A small number of studies have suggested that service variables may impact on intervention effectiveness and hence placement breakdown. This study used a non-experimental group comparison design to investigate potential differences between two groups of residential homes, one of which had experienced placement breakdown, and one of which had successfully maintained placements in the community. More residents in the breakdown group had inappropriate sexual behaviours but there were no other differences. Services in the breakdown group had more limited procedural guidance for staff, weaker training, supervision and team meetings and less external professional support. Placement characteristics may be an important determinant of community placement success for people with IDs and challenging behaviour. Those selecting and funding residential placements for such people should attend to the technical competence of the placement (in terms of its use of procedural guidance, training and professional advice) and to the extent of support for staff (in terms of training, supervision and team meetings).

  4. International students in speech-language pathology clinical education placements: Perceptions of experience and competency development.

    PubMed

    Attrill, Stacie; Lincoln, Michelle; McAllister, Sue

    2015-06-01

    This study aimed to describe perceptions of clinical placement experiences and competency development for international speech-language pathology students and to determine if these perceptions were different for domestic students. Domestic and international students at two Australian universities participated in nine focus group interviews. Thematic analysis led to the identification of two themes shared by international and domestic students and several separate themes. Shared themes identified the important influence of students' relationships with clinical educators, unique opportunities and learning that occurs on placement. International student themes included concerns about their communication skills and the impact of these skills on client progress. They also explored their adjustment to unfamiliar placement settings and relationships, preferring structured placements to assist this adjustment. Domestic student themes explored the critical nature of competency attainment and assessment on placement, valuing placements that enabled them to achieve their goals. The findings of this study suggest that international students experience additional communication, cultural and contextual demands on clinical placement, which may increase their learning requirements. Clinical education practices must be responsive to the learning needs of diverse student populations. Strategies are suggested to assist all students to adjust to the professional and learning expectations of clinical education placements.

  5. Preferences for condom placement in stores among young Dutch men and women: relationships with embarrassment and motives for having sex.

    PubMed

    Gebhardt, Winifred A; van der Doef, Margot P; Billingy, Nicole; Carstens, Malou; Steenhuis, Ingrid

    2012-07-01

    Condom purchasing is an important preparation for condom use. The present study examined if products surrounding condoms in the store play a role in preferences for where to buy condoms among young people. Sixty-nine men and 111 women (<30 years) completed an online questionnaire on their preferences for condom placement, associated embarrassment with these placements, and motives for having sex. Fifty percent of men and 70% of women indicated the counter as least preferred placement. Two-fifths of men and women preferred the sensual context, including among sex toys and lubricants; however, the remainder of participants, particularly women, preferred other less sexual contexts. Both the counter and sensual placement were strongly associated with embarrassment, and this, in turn, was predictive of placement preference. Finally, the motive for having sex to experience intimacy was negatively related to counter preference, and the motive for having sex to experience pleasure was negatively related to the neutral placement and the female personal care placement preferences. The findings suggest that using multiple and alternative placements for condoms in stores may encourage condom purchasing behaviour among young people.

  6. Delayed Implants Outcome in Maxillary Molar Region.

    PubMed

    Crespi, Roberto; Capparè, Paolo; Crespi, Giovanni; Gastaldi, Giorgio; Gherlone, Enrico F

    2017-04-01

    The aim of the present study was to assess bone volume changes in maxillary molar regions after delayed implants placement. Patients presented large bone defects after tooth extractions. Reactive soft tissue was left into the defects. No grafts were used. Cone beam computed tomography (CBCT) scans were performed before tooth extractions, at implant placement (at 3 months from extraction) and 3 years after implant placement, bone volume measurements were assessed. Bucco-lingual width showed a statistically significant decrease (p = .013) at implant placement, 3 months after extraction. Moreover, a statistically significant increase (p < .01) was measured 3 years after implant placement. No statistically significant differences (p > .05) were found between baseline values (before extraction) and at 3 years from implant placement. Vertical dimension showed no statistically significant differences (p > .05) at implant placement, 3 months after extraction. Statistically significant differences (p < .0001) were found between baseline values (before extraction) and at 3 months from implant placement as well as between implant placement values and 3 years later. CT scans presented successful outcome of delayed implants placed in large bone defects at 3-year follow-up. © 2016 Wiley Periodicals, Inc.

  7. First impressions count: does FAIRness affect adaptation of clinical clerks in their first clinical placement?

    PubMed

    Edafe, Ovie; Mistry, Natasha; Chan, Philip

    2013-09-01

    FAIRness (Feedback, Activity, Individualisation, Relevance) teaching is a structured program, comprising series of classes in which student work is anonymised and reviewed by the whole class, as well as students receiving private feedback on their written work. The class work emphasises logic, structure and order in history and examination, with a diagnostic and management focus. The effect of FAIRness teaching methods on the adaptation of medical students entering their first clinical rotations was studied. 18 students in FAIRness placements and 72 students in conventional placements, all in medical/surgical units in the same University teaching hospital were studied. They completed questionnaires relating to effectiveness and quality of clinical teaching. Some students additionally attended focus groups, at the start of placement to discuss their expectations, and after 3 weeks, to discuss their adaptation to the clinical learning environment. All students entering clinical placements had low expectations of their future teaching. Students in standard placements still expressed negative attitudes after 3 weeks, while students on FAIRness placements felt positive. Students in FAIRness placements scored significantly higher on questions related to feedback and review of student work. FAIRness teaching practices help students to adapt to their first clinical placements.

  8. 76 FR 17963 - Renewal of Agency Information Collection for Application for Job Placement and Training Services...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-03-31

    ... training program, which provides vocational/technical training, related counseling, guidance, job placement... the job placement and training program, which provides vocational/technical training, related... Application for Job Placement and Training Services; Request for Comments AGENCY: Bureau of Indian Affairs...

  9. Selected Studies on Math Placement.

    ERIC Educational Resources Information Center

    Akst, Geoffrey; Hirsch, Lewis

    1991-01-01

    Drawing from a review of the literature and direct experience, this paper discusses key issues in developmental mathematics placement. First, the controversial practice of mandatory placement is examined, citing research results that support the practice and those that do not. Next, the diversity of developmental math placement standards is…

  10. Humanitarian Engineering Placements in Our Own Communities

    ERIC Educational Resources Information Center

    VanderSteen, J. D. J.; Hall, K. R.; Baillie, C. A.

    2010-01-01

    There is an increasing interest in the humanitarian engineering curriculum, and a service-learning placement could be an important component of such a curriculum. International placements offer some important pedagogical advantages, but also have some practical and ethical limitations. Local community-based placements have the potential to be…

  11. Design of a head phantom produced on a 3D rapid prototyping printer and comparison with a RANDO and 3M lucite head phantom in eye dosimetry applications

    NASA Astrophysics Data System (ADS)

    Homolka, Peter; Figl, Michael; Wartak, Andreas; Glanzer, Mathias; Dünkelmeyer, Martina; Hojreh, Azadeh; Hummel, Johann

    2017-04-01

    An anthropomorphic head phantom including eye inserts allowing placement of TLDs 3 mm below the cornea has been produced on a 3D printer using a photo-cured acrylic resin to best allow tissue equivalence. Thus Hp(3) can be determined in radiological and interventional photon radiation fields. Eye doses and doses to the forehead have been compared to an Alderson RANDO head and a 3M Lucite skull phantom in terms of surface dose per incident air kerma for frontal irradiation since the commercial phantoms do not allow placement of TLDs 3 mm below the corneal surface. A comparison of dose reduction factors (DRFs) of a common lead glasses model has also been performed. Eye dose per incident air kerma were comparable between all three phantoms (printed phantom: 1.40, standard error (SE) 0.04; RANDO: 1.36, SE 0.03; 3M: 1.37, SE 0.03). Doses to the forehead were identical to eye surface doses for the printed phantom and the RANDO head (ratio 1.00 SE 0.04, and 0.99 SE 0.03, respectively). In the 3M Lucite skull phantom dose on the forehead was 15% lower than dose to the eyes attributable to phantom properties. DRF of a sport frame style leaded glasses model with 0.75 mm lead equivalence measured were 6.8 SE 0.5, 9.3 SE 0.4 and 10.5 SE 0.5 for the RANDO head, the printed phantom, and the 3M Lucite head phantom, respectively, for frontal irradiation. A comparison of doses measured in 3 mm depth and on the surface of the eyes in the printed phantom revealed no difference larger than standard errors from TLD dosimetry. 3D printing offers an interesting opportunity for phantom design with increasing potential as printers allowing combinations of tissue substitutes will become available. Variations between phantoms may provide a useful indication of uncertainty budgets when using phantom measurements to estimate individual personnel doses.

  12. Development and validation of a new guidance device for lateral approach stereotactic breast biopsy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ma, K.; Kornecki, A.; Bax, J.

    2009-06-15

    Stereotactic breast biopsy (SBB) is the gold standard for minimally invasive breast cancer diagnosis. Current systems rely on one of two methods for needle insertion: A vertical approach (perpendicular to the breast compression plate) or a lateral approach (parallel to the compression plate). While the vertical approach is more frequently used, it is not feasible in patients with thin breasts (<3 cm thick after compression) or with superficial lesions. Further, existing SBB guidance hardware provides at most one degree of rotational freedom in the needle trajectory, and as such requires a separate skin incision for each biopsy target. The authorsmore » present a new design of lateral guidance device for SBB, which addresses the limitations of the vertical approach and provides improvements over the existing lateral guidance hardware. Specifically, the new device provides (1) an adjustable rigid needle support to minimize needle deflection within the breast and (2) an additional degree of rotational freedom in the needle trajectory, allowing the radiologist to sample multiple targets through a single skin incision. This device was compared to a commercial lateral guidance device in a series of phantom experiments. Needle placement error using each device was measured in agar phantoms for needle insertions at lateral depths of 2 and 5 cm. The biopsy success rate for each device was then estimated by performing biopsy procedures in commercial SBB phantoms. SBB performed with the new lateral guidance device provided reduced needle placement error relative to the commercial lateral guidance device (0.89{+-}0.22 vs 1.75{+-}0.35 mm for targets at 2 cm depth; 1.94{+-}0.20 vs 3.21{+-}0.31 mm for targets at 5 cm depth). The new lateral guidance device also provided improved biopsy accuracy in SBB procedures compared to the commercial lateral guidance device (100% vs 58% success rate). Finally, experiments were performed to demonstrate that the new device can accurately sample lesions within thin breast phantoms and multiple lesions through a single incision point. This device can be incorporated directly into the clinical SBB procedural workflow, with no additional electrical hardware, software, postprocessing, or image analysis.« less

  13. Design of a head phantom produced on a 3D rapid prototyping printer and comparison with a RANDO and 3M lucite head phantom in eye dosimetry applications.

    PubMed

    Homolka, Peter; Figl, Michael; Wartak, Andreas; Glanzer, Mathias; Dünkelmeyer, Martina; Hojreh, Azadeh; Hummel, Johann

    2017-04-21

    An anthropomorphic head phantom including eye inserts allowing placement of TLDs 3 mm below the cornea has been produced on a 3D printer using a photo-cured acrylic resin to best allow tissue equivalence. Thus H p (3) can be determined in radiological and interventional photon radiation fields. Eye doses and doses to the forehead have been compared to an Alderson RANDO head and a 3M Lucite skull phantom in terms of surface dose per incident air kerma for frontal irradiation since the commercial phantoms do not allow placement of TLDs 3 mm below the corneal surface. A comparison of dose reduction factors (DRFs) of a common lead glasses model has also been performed. Eye dose per incident air kerma were comparable between all three phantoms (printed phantom: 1.40, standard error (SE) 0.04; RANDO: 1.36, SE 0.03; 3M: 1.37, SE 0.03). Doses to the forehead were identical to eye surface doses for the printed phantom and the RANDO head (ratio 1.00 SE 0.04, and 0.99 SE 0.03, respectively). In the 3M Lucite skull phantom dose on the forehead was 15% lower than dose to the eyes attributable to phantom properties. DRF of a sport frame style leaded glasses model with 0.75 mm lead equivalence measured were 6.8 SE 0.5, 9.3 SE 0.4 and 10.5 SE 0.5 for the RANDO head, the printed phantom, and the 3M Lucite head phantom, respectively, for frontal irradiation. A comparison of doses measured in 3 mm depth and on the surface of the eyes in the printed phantom revealed no difference larger than standard errors from TLD dosimetry. 3D printing offers an interesting opportunity for phantom design with increasing potential as printers allowing combinations of tissue substitutes will become available. Variations between phantoms may provide a useful indication of uncertainty budgets when using phantom measurements to estimate individual personnel doses.

  14. Avian furcula morphology may indicate relationships of flight requirements among birds

    USGS Publications Warehouse

    Hui, C.A.

    2002-01-01

    This study examined furcula (wishbone) shape relative to flight requirements. The furculae from 53 museum specimens in eight orders were measured: 1) three-dimensional shape (SR) as indicated by the ratio of the direct distance between the synostosis interclavicularis and the ligamentous attachment of one of its clavicles to the actual length of the clavicle between those same two points, and 2) curvature within the primary plane (LR) as indicated by the ratio of the length of the clavicle to the sum of the orthogonal distances between the same points using a projected image. Canonical discriminant analysis of these ratios placed the individuals into a) one of four general flight categories and b) one of eight taxonomic orders. The four flight categories were defined as: i) soaring with no flapping, ii) flapping with no soaring, iii) subaqueous (i.e., all wingbeats taking place under water), and iv) partial subaqueous (i.e., wingbeats used for both aerial and submerged flapping). The error rate for placement of the specimens in flight categories was only 26.4%, about half of the error rate for placement in taxonomic orders (51.3%). Subaqueous fliers (penguins, great auks) have furculae that are the most V-shaped. Partial subaqueous fliers (alcids, storm petrels) have furculae that are more U-shaped than the subaqueous fliers but more V-shaped than the aerial flapping fliers. The partial subaqueous fliers have furculae that are also the most anteriorly curved, possibly increasing protraction capability by changing the angle of applied force and increasing attachment area for the origin of the sternobrachialis pectoralis. The increased protraction capability can counteract profile drag, which is greater in water than in air due to the greater density of water. Soaring birds have furculae that are more U-shaped or circular than those of flapping birds and have the smallest range of variation. These results indicate that the shape of the furcula is functionally related to general differences in flight requirements and may be used to infer relationships of these requirements among birds. ?? 2002 Wiley-Liss, Inc.

  15. Impact of an international workplace learning placement on personal and professional development.

    PubMed

    Davies, Kerryn; Curtin, Michael; Robson, Kristy

    2017-04-01

    Workplace learning (WPL) placements are a mandatory part of occupational therapy courses. There is some evidence that suggests WPL placements in international settings are beneficial for students' learning, and personal and professional development. The aim of this study was to explore the impact an international WPL placement in Vietnam had on the perceived personal and professional development of a group of Australian occupational therapy graduates. Interpretative phenomenological analysis was used to explore the perceptions of how participation in the Charles Sturt University School of Community Health's Vietnam placement influenced the personal and professional development of occupational therapy graduates. Individual semi-structured interviews were conducted with nine graduates who participated in the Vietnam placement when they were final year occupational therapy students. Interviews were audio-recorded, transcribed verbatim and individually analysed to identify key themes. Two major themes emerged from the analysis: becoming resourceful, resilient and confident, and becoming respectful of difference. The participants indicated that participation in the Vietnam placement had a positive impact on their personal and professional development. Participants indicated that the Vietnam placement enabled them to develop their resourcefulness, resilience, reasoning skills, cultural competence, confidence and independence, beyond what they felt would have achieved on a domestic placement. For these reason these participants found the placement a beneficial and worthwhile experience. © 2016 Occupational Therapy Australia.

  16. Foster care assessment: A study of the placement decision process in Flanders.

    PubMed

    Vanderfaeillie, Johan; Pijnenburg, Huub; Damen, Harm; Van Holen, Frank

    2015-11-01

    Family foster care placement decision-making has a weak scientific underpinning. Mostly a 'variable-oriented approach' is taken, which requires a lot of information that is not always available. The identification of clusters of foster children with similar characteristics may be a more viable decision strategy. In this study we investigated if foster children could indeed be clustered, which problems were identified at the time of placement, and the influence of placement history. It proved possible to group foster children into two clusters: (1) young children with familial problems and few behavioral problems, and (2) older children with prominent child problems and behavioral problems. For foster children with and without placement history, problems associated with placement proved identical. Considering that a foster care placement did not result in fundamental change in the problems present at time of placement, the importance is stressed of approaching foster care assessment as part of a decision making process which looks back as well as forward. Placement decisions should be based on an appraisal of the appropriateness of foster placement as a solution for the child. In conjunction with this appraisal a decision is required on how parents can be supported toward reunification. Or--if this is not an option--whether long term foster care is the best option for the child and if so, what conditions need to be met. Copyright © 2015 Elsevier Ltd. All rights reserved.

  17. Foster care placement change: The role of family dynamics and household composition

    PubMed Central

    Waid, Jeffrey; Kothari, Brianne H.; Bank, Lew; McBeath, Bowen

    2016-01-01

    Sibling co-placement and kinship care have each been shown to protect against the occurrence of placement change for youth in substitute care. However, little is known about the effects of different combinations of sibling placement and relative caregiver status on placement change. Nor does the field fully understand how family dynamics may differ in these households. Utilizing data from the Supporting Siblings in Foster Care study, this paper examines family dynamics across four typologies of living composition, and tests the effects of living composition membership on the odds of experiencing a placement change over an 18-month period of time. Findings suggest that across living composition typologies, children who were placed separately from their siblings in non-relative care were more likely to be older, have more extensive placement histories, and experience more placement changes both prior to and during the study than were children in other living composition groups. Family living composition was found to influence the occurrence of placement change. Specifically, children co-placed in kinship care were least likely to experience movement; however, sibling co-placement in non-relative care was also protective. Results reveal the need to conduct additional research into the experiences of children in different family living arrangements, and tailor case management services and supports to children in substitute care accordingly. Implications and future directions are discussed. PMID:27990039

  18. Transpyloric Feeding Tube Placement Using Electromagnetic Placement Device in Children.

    PubMed

    Goggans, Margaret; Pickard, Sharon; West, Alina Nico; Shah, Samir; Kimura, Dai

    2017-04-01

    Transpyloric feeding tubes (TPT) are often recommended in critically ill children. Blind tube placement, however, can be difficult, be time-consuming, and incur multiple radiation exposures. An electromagnetic device (EMD) is available for confirmation of successful placement of TPTs. We conducted a retrospective cohort study to evaluate the efficacy of an EMD for TPT placement in children and determine its impact on placement success, radiation exposure, confirmation time, and cost for tube placement compared with traditional blind TPT placement. Retrospective data were collected in patients receiving a TPT before (pre-EMD group) and after implementation of an EMD (EMD group). Need for radiographic exposure decreased significantly in the EMD group (n = 40) compared with the pre-EMD group (n = 38) (0.6 vs 1.6 x-rays, P < .001). TPTs were placed and confirmed without abdominal x-ray in 21 of 40 patients in the EMD group. There were no serious adverse events such as misplacement into the lung or pneumothorax or perforation injury of the stomach. Successful tube confirmation took a significantly shorter time in the EMD group than in the pre-EMD group (1.45 vs 4.59 hours, P < .0001). There was an estimated cost savings of $245.10 per placement associated with decreased x-ray and fluoroscopy. The use of an EMD in children significantly decreased radiation exposure and confirmation time while maintaining TPT placement success. The use of an EMD can potentially offer large cost savings. Elimination of abdominal x-ray with EMD during TPT placement was achieved without any serious complications in approximately half of the children.

  19. Behavior problems and placement change in a national child welfare sample: a prospective study.

    PubMed

    Aarons, Gregory A; James, Sigrid; Monn, Amy R; Raghavan, Ramesh; Wells, Rebecca S; Leslie, Laurel K

    2010-01-01

    There is ongoing debate regarding the impact of youth behavior problems on placement change in child welfare compared to the impact of placement change on behavior problems. Existing studies provide support for both perspectives. The purpose of this study was to prospectively examine the relations of behavior problems and placement change in a nationally representative sample of youths in the National Survey of Child and Adolescent Well-Being. The sample consisted of 500 youths in the child welfare system with out-of-home placements over the course of the National Survey of Child and Adolescent Well-Being study. We used a prospective cross-lag design and path analysis to examine reciprocal effects of behavior problems and placement change, testing an overall model and models examining effects of age and gender. In the overall model, out of a total of eight path coefficients, behavior problems significantly predicted placement changes for three paths and placement change predicted behavior problems for one path. Internalizing and externalizing behavior problems at baseline predicted placement change between baseline and 18 months. Behavior problems at an older age and externalizing behavior at 18 months appear to confer an increased risk of placement change. Of note, among female subjects, placement changes later in the study predicted subsequent internalizing and externalizing behavior problems. In keeping with recommendations from a number of professional bodies, we suggest that initial and ongoing screening for internalizing and externalizing behavior problems be instituted as part of standard practice for youths entering or transitioning in the child welfare system.

  20. Utilisation of the healthcare system for authentic early experience placements.

    PubMed

    Hays, Richard B

    2013-01-01

    Authentic early experience in clinical contexts adds interest and relevance to basic medical education, and is regarded positively by both learners and teachers. However, with the recent expansion of medical education, the healthcare system appears close to reaching its capacity for student supervision. This study explores the utilisation of the healthcare system for early clinical placements. A secondary analysis was conducted of data from the Medical Schools Outcomes Database, collected from the 2010 annual questionnaire, focusing on the timing, duration and location of clinical placements during 2009 within the first half of basic medical education programs in Australia. Data was received for 67% of Australian medical students, reporting a total of 16 812 early clinical placements that occupied 97 319 days of supervised time in a wide variety of hospital, general practice and Indigenous health contexts, both urban and rural, across the Australian healthcare system. These early placements occupied about 16% of total clinical placement time for all students in all training years during 2009. The majority of these placements were for only a few hours or days; exceptions were longitudinal placements in regional and rural communities at a minority of schools. Early clinical placements may pose significant resource costs for placement providers, particularly supervision time and expertise. As medical education expands and the teaching capacity of the Australian healthcare system appears to reach its limits, it may be necessary to allocate placements according to their specific learning outcomes, prioritise more acute settings for more senior students, and increase capacity in less acute health and social care settings.

  1. Mathematics Placement at the University of Illinois

    ERIC Educational Resources Information Center

    Ahlgren Reddy, Alison; Harper, Marc

    2013-01-01

    Data from the ALEKS-based placement program at the University of Illinois is presented visually in several ways. The placement exam (an ALEKS assessment) contains precise item-specific information and the data show many interesting properties of the student populations of the placement courses, which include Precalculus, Calculus, and Business…

  2. Brevard District Plan for Placement and Follow-Up.

    ERIC Educational Resources Information Center

    Thomas, Olive W.

    The Brevard District Plan for placement and follow-up is intended for all secondary students, including dropouts, disadvantaged, adult students, and graduates. The areas of placement may be in gainful employment, educational institutions, or a combination of both. The plan specifies procedures for implementing placement and stipulates the type of…

  3. 38 CFR 21.252 - Job development and placement services.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 38 Pensions, Bonuses, and Veterans' Relief 2 2014-07-01 2014-07-01 false Job development and... 38 U.S.C. Chapter 31 Employment Services § 21.252 Job development and placement services. (a) General. Job development and placement services may include: (1) Direct placement assistance by VA; (2...

  4. 38 CFR 21.252 - Job development and placement services.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 38 Pensions, Bonuses, and Veterans' Relief 2 2013-07-01 2013-07-01 false Job development and... 38 U.S.C. Chapter 31 Employment Services § 21.252 Job development and placement services. (a) General. Job development and placement services may include: (1) Direct placement assistance by VA; (2...

  5. 38 CFR 21.252 - Job development and placement services.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 38 Pensions, Bonuses, and Veterans' Relief 2 2011-07-01 2011-07-01 false Job development and... 38 U.S.C. Chapter 31 Employment Services § 21.252 Job development and placement services. (a) General. Job development and placement services may include: (1) Direct placement assistance by VA; (2...

  6. 38 CFR 21.252 - Job development and placement services.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 38 Pensions, Bonuses, and Veterans' Relief 2 2012-07-01 2012-07-01 false Job development and... 38 U.S.C. Chapter 31 Employment Services § 21.252 Job development and placement services. (a) General. Job development and placement services may include: (1) Direct placement assistance by VA; (2...

  7. 7. View showing placement of timber deck placement on chord ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    7. View showing placement of timber deck placement on chord and built up construction of top chord and continuous construction through top panel points, eye bar construction on bottom chord - Bridge No. 2.4, Spanning Boiling Fork Creek at Railroad Milepost JC-2.4, Decherd, Franklin County, TN

  8. VR Placement Policy and Field Office Production. Studies in Placement Monograph No. 5.

    ERIC Educational Resources Information Center

    Pretz, David S.; And Others

    A study examined the relationship between vocational education rehabilitation agency placement policy and field office productivity. A total of 112 counselors and 25 supervisors from twenty-two Division of Vocational Rehabilitation field offices from seven states were given questionnaires covering different facets of placement policy including…

  9. 28 CFR 551.24 - Child placement.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 28 Judicial Administration 2 2013-07-01 2013-07-01 false Child placement. 551.24 Section 551.24... Birth Control, Pregnancy, Child Placement, and Abortion § 551.24 Child placement. (a) The Warden may not permit the inmate's new born child to return to the institution except in accordance with the Bureau of...

  10. 28 CFR 551.24 - Child placement.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 28 Judicial Administration 2 2012-07-01 2012-07-01 false Child placement. 551.24 Section 551.24... Birth Control, Pregnancy, Child Placement, and Abortion § 551.24 Child placement. (a) The Warden may not permit the inmate's new born child to return to the institution except in accordance with the Bureau of...

  11. 28 CFR 551.24 - Child placement.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 28 Judicial Administration 2 2014-07-01 2014-07-01 false Child placement. 551.24 Section 551.24... Birth Control, Pregnancy, Child Placement, and Abortion § 551.24 Child placement. (a) The Warden may not permit the inmate's new born child to return to the institution except in accordance with the Bureau of...

  12. 28 CFR 551.24 - Child placement.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 28 Judicial Administration 2 2011-07-01 2011-07-01 false Child placement. 551.24 Section 551.24... Birth Control, Pregnancy, Child Placement, and Abortion § 551.24 Child placement. (a) The Warden may not permit the inmate's new born child to return to the institution except in accordance with the Bureau of...

  13. 28 CFR 551.24 - Child placement.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 28 Judicial Administration 2 2010-07-01 2010-07-01 false Child placement. 551.24 Section 551.24... Birth Control, Pregnancy, Child Placement, and Abortion § 551.24 Child placement. (a) The Warden may not permit the inmate's new born child to return to the institution except in accordance with the Bureau of...

  14. Keyword: Placement

    ERIC Educational Resources Information Center

    Cassuto, Leonard

    2012-01-01

    The practical goal of graduate education is placement of graduates. But what does "placement" mean? Academics use the word without thinking much about it. "Placement" is a great keyword for the graduate-school enterprise. For one thing, its meaning certainly gives a purpose to graduate education. Furthermore, the word is a portal into the way of…

  15. Why are mini-implants lost: the value of the implantation technique!

    PubMed

    Romano, Fabio Lourenço; Consolaro, Alberto

    2015-01-01

    The use of mini-implants have made a major contribution to orthodontic treatment. Demand has aroused scientific curiosity about implant placement procedures and techniques. However, the reasons for instability have not yet been made totally clear. The aim of this article is to establish a relationship between implant placement technique and mini-implant success rates by means of examining the following hypotheses: 1) Sites of poor alveolar bone and little space between roots lead to inadequate implant placement; 2) Different sites require mini-implants of different sizes! Implant size should respect alveolar bone diameter; 3) Properly determining mini-implant placement site provides ease for implant placement and contributes to stability; 4) The more precise the lancing procedures, the better the implant placement technique; 5) Self-drilling does not mean higher pressures; 6) Knowing where implant placement should end decreases the risk of complications and mini-implant loss.

  16. Relationship of risk assessment to placement characteristics in a statewide child welfare population.

    PubMed

    Huang, Cindy Y; Bory, Christopher T; Caron, Colleen; Tebes, Jacob Kraemer; Connell, Christian M

    2014-11-01

    Risk assessments allow child and youth services to identify children who are at risk for maltreatment (e.g., abuse, neglect) and help determine the restrictiveness of placements or need for services among youth entering a child welfare system. Despite the use of instruments by many agencies within the U.S. to determine the appropriate placements for youth, research has shown that placement decisions are often influenced by factors such as gender, age, and severity of social-emotional and behavior problems. This study examined ratings of risk across multiple domains using a structured assessment tool used by caseworkers in the Rhode Island child welfare system. The relationship between ratings of risk and placement restrictiveness was also examined. Risk levels varied across placement settings. Multivariate analyses revealed that lower caseworker ratings of parent risk and higher ratings of youth risk were associated with more restrictive placements for youth. Implications for the child welfare system are discussed.

  17. Placement Component, Lincoln Career Education Project. Final Report. March, 1973-June, 1976.

    ERIC Educational Resources Information Center

    Novak, Carl D.; And Others

    The goal of the placement component of the 3-year Lincoln Career Education Project, Nebraska, was to establish placement services for youth of participating project schools. "Placement" referred not only to helping exiting senior high youth find employment, but also to developing the knowledge, skills, and attitudes which lead to…

  18. Materials and Area of Study for Advanced Placement Program in American History.

    ERIC Educational Resources Information Center

    Santos, Peter A.

    This paper describes and evaluates benefits of advanced placement programs and identifies materials which can help high school history classroom teachers develop effective advanced placement programs. An advanced placement program is defined as a program which requires a student to do extensive research and writing throughout the school year.…

  19. Brand placement and consumer choice: an in-store experiment.

    PubMed

    Sigurdsson, Valdimar; Saevarsson, Hugi; Foxall, Gordon

    2009-01-01

    An in-store experiment was performed to investigate the effects of shelf placement (high, middle, low) on consumers' purchases of potato chips. Placement of potato chips on the middle shelf was associated with the highest percentage of purchases. The results confirm the importance of item placement as a factor in consumers' buying behavior.

  20. 37 CFR 211.6 - Methods of affixation and placement of mask work notice.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... placement of mask work notice. 211.6 Section 211.6 Patents, Trademarks, and Copyrights COPYRIGHT OFFICE, LIBRARY OF CONGRESS COPYRIGHT OFFICE AND PROCEDURES MASK WORK PROTECTION § 211.6 Methods of affixation and placement of mask work notice. (a) General. (1) This section specifies methods of affixation and placement...