Sample records for plasma samples analysis

  1. A simple method for plasma total vitamin C analysis suitable for routine clinical laboratory use.

    PubMed

    Robitaille, Line; Hoffer, L John

    2016-04-21

    In-hospital hypovitaminosis C is highly prevalent but almost completely unrecognized. Medical awareness of this potentially important disorder is hindered by the inability of most hospital laboratories to determine plasma vitamin C concentrations. The availability of a simple, reliable method for analyzing plasma vitamin C could increase opportunities for routine plasma vitamin C analysis in clinical medicine. Plasma vitamin C can be analyzed by high performance liquid chromatography (HPLC) with electrochemical (EC) or ultraviolet (UV) light detection. We modified existing UV-HPLC methods for plasma total vitamin C analysis (the sum of ascorbic and dehydroascorbic acid) to develop a simple, constant-low-pH sample reduction procedure followed by isocratic reverse-phase HPLC separation using a purely aqueous low-pH non-buffered mobile phase. Although EC-HPLC is widely recommended over UV-HPLC for plasma total vitamin C analysis, the two methods have never been directly compared. We formally compared the simplified UV-HPLC method with EC-HPLC in 80 consecutive clinical samples. The simplified UV-HPLC method was less expensive, easier to set up, required fewer reagents and no pH adjustments, and demonstrated greater sample stability than many existing methods for plasma vitamin C analysis. When compared with the gold-standard EC-HPLC method in 80 consecutive clinical samples exhibiting a wide range of plasma vitamin C concentrations, it performed equivalently. The easy set up, simplicity and sensitivity of the plasma vitamin C analysis method described here could make it practical in a normally equipped hospital laboratory. Unlike any prior UV-HPLC method for plasma total vitamin C analysis, it was rigorously compared with the gold-standard EC-HPLC method and performed equivalently. Adoption of this method could increase the availability of plasma vitamin C analysis in clinical medicine.

  2. The use of frozen plasma samples in thromboelastometry.

    PubMed

    Schoergenhofer, Christian; Buchtele, Nina; Schwameis, Michael; Bartko, Johann; Jilma, Bernd; Jilma-Stohlawetz, Petra

    2017-11-01

    Thromboelastometry is increasingly used in the clinical and scientific setting. The use of frozen plasma samples may be useful in overcoming certain limitations such as local and timely availability. Whole blood (WB) samples of 20 healthy volunteers were obtained, and plasma was generated. NATEM (n = 20), EXTEM (n = 20) and INTEM (n = 8) analyses were performed in WB, fresh plasma and frozen and thawed plasma. Dabigatran (500, 1000 ng/ml), rivaroxaban (100, 200 ng/ml) or alteplase (333 ng/ml) were added ex vivo to WB, and thromboelastometry was performed in WB and in frozen and thawed plasma samples. Clot formation time, mean clot firmness and the area under the curve were significantly altered in plasma compared to WB. In INTEM and EXTEM analysis, clotting time (CT) was comparable between WB (100%) and fresh (INTEM 114% and EXTEM 93%, ratio of the means) and frozen plasma samples (85 and 99%), whereas in NATEM analysis, the CT increased in fresh (193%) and frozen plasma samples (130%). Dabigatran dose-dependently increased the CT approximately 5- and 9-fold in WB and even more pronounced 10- and 26-fold in plasma. Accordingly, rivaroxaban dose-dependently increased the CT 2- and 2.7-fold in WB, and 3.5- and 4-fold in plasma samples. Hyperfibrinolysis was achieved by addition of alteplase in all WB samples and was reproducible in plasma samples. In conclusion, thromboelastometry, especially INTEM and EXTEM analyses, is possible using frozen and stored plasma samples with comparable results to the corresponding whole blood samples.

  3. Method and apparatus for chemical and topographical microanalysis

    NASA Technical Reports Server (NTRS)

    Kossakovski, Dmitri A. (Inventor); Baldeschwieler, John D. (Inventor); Beauchamp, Jesse L. (Inventor)

    2002-01-01

    A scanning probe microscope is combined with a laser induced breakdown spectrometer to provide spatially resolved chemical analysis of the surface correlated with the surface topography. Topographical analysis is achieved by scanning a sharp probe across the sample at constant distance from the surface. Chemical analysis is achieved by the means of laser induced breakdown spectroscopy by delivering pulsed laser radiation to the sample surface through the same sharp probe, and consequent collection and analysis of emission spectra from plasma generated on the sample by the laser radiation. The method comprises performing microtopographical analysis of the sample with a scanning probe, selecting a scanned topological site on the sample, generating a plasma plume at the selected scanned topological site, and measuring a spectrum of optical emission from the plasma at the selected scanned topological site. The apparatus comprises a scanning probe, a pulsed laser optically coupled to the probe, an optical spectrometer, and a controller coupled to the scanner, laser and spectrometer for controlling the operation of the scanner, laser and spectrometer. The probe and scanner are used for topographical profiling the sample. The probe is also used for laser radiation delivery to the sample for generating a plasma plume from the sample. Optical emission from the plasma plume is collected and delivered to the optical spectrometer so that analysis of emission spectrum by the optical spectrometer allows for identification of chemical composition of the sample at user selected sites.

  4. Matrix-Assisted Plasma Atomization Emission Spectrometry for Surface Sampling Elemental Analysis

    PubMed Central

    Yuan, Xin; Zhan, Xuefang; Li, Xuemei; Zhao, Zhongjun; Duan, Yixiang

    2016-01-01

    An innovative technology has been developed involving a simple and sensitive optical spectrometric method termed matrix-assisted plasma atomization emission spectrometry (MAPAES) for surface sampling elemental analysis using a piece of filter paper (FP) for sample introduction. MAPAES was carried out by direct interaction of the plasma tail plume with the matrix surface. The FP absorbs energy from the plasma source and releases combustion heating to the analytes originally present on its surface, thus to promote the atomization and excitation process. The matrix-assisted plasma atomization excitation phenomenon was observed for multiple elements. The FP matrix served as the partial energy producer and also the sample substrate to adsorb sample solution. Qualitative and quantitative determinations of metal ions were achieved by atomic emission measurements for elements Ba, Cu, Eu, In, Mn, Ni, Rh and Y. The detection limits were down to pg level with linear correlation coefficients better than 0.99. The proposed MAPAES provides a new way for atomic spectrometry which offers advantages of fast analysis speed, little sample consumption, less sample pretreatment, small size, and cost-effective. PMID:26762972

  5. Sample Preparation Report of the Fourth OPCW Confidence Building Exercise on Biomedical Sample Analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Udey, R. N.; Corzett, T. H.; Alcaraz, A.

    Following the successful completion of the 3rd biomedical confidence building exercise (February 2013 – March 2013), which included the analysis of plasma and urine samples spiked at low ppb levels as part of the exercise scenario, another confidence building exercise was targeted to be conducted in 2014. In this 4th exercise, it was desired to focus specifically on the analysis of plasma samples. The scenario was designed as an investigation of an alleged use of chemical weapons where plasma samples were collected, as plasma has been reported to contain CWA adducts which remain present in the human body for severalmore » weeks (Solano et al. 2008). In the 3rd exercise most participants used the fluoride regeneration method to analyze for the presence of nerve agents in plasma samples. For the 4th biomedical exercise it was decided to evaluate the analysis of human plasma samples for the presence/absence of the VX adducts and aged adducts to blood proteins (e.g., VX-butyrylcholinesterase (BuChE) and aged BuChE adducts using a pepsin digest technique to yield nonapeptides; or equivalent). As the aging of VX-BuChE adducts is relatively slow (t1/2 = 77 hr at 37 °C [Aurbek et al. 2009]), soman (GD), which ages much more quickly (t1/2 = 9 min at 37 °C [Masson et al. 2010]), was used to simulate an aged VX sample. Additional objectives of this exercise included having laboratories assess novel OP-adducted plasma sample preparation techniques and analytical instrumentation methodologies, as well as refining/designating the reporting formats for these new techniques.« less

  6. Spatial-temporal diagnostics of the system of a plasma stream interacting with a surface of heat resistant material

    NASA Astrophysics Data System (ADS)

    Chinnov, V. F.; Sargsyan, M. A.; Gadzhiev, M. Kh; Khromov, M. A.; Kavyrshin, D. I.; Chistolinov, A. V.

    2018-01-01

    In an automated measuring complex using optical and spectral methods the spatial and temporal changes in the parameters and composition of nitrogen plasma jet were investigated. The plasma jet was flowing out of the nozzle of the plasma torch with 10-12 kK temperature and acting on the sample of MPG-6 graphite. Due to the heating of the sample to the temperatures of 2.5-3 kK the influence of the sublimating material of the sample on the plasma composition and temperature in the near-surface region of the sample was investigated. An original method based on the analysis of movement of optical inhomogeneities in the plasma flow was used to estimate the plasma jet velocity in the region where it interacts with the sample. The combined analysis of the results of two-positioning video recordings opens up the possibility of determining spatial-temporal distributions of the plasma jet velocities, in medium and high pressure environments, in the ranges from few to thousands of m/s and 3-15 kK temperatures.

  7. Metabolomics: A Window for Understanding Long Term Physical Consequences of Distrubed Sleep and Hypothalamic Pituitary Adrenal Function in Posttraumatic Stress

    DTIC Science & Technology

    2017-09-01

    performed on pre -collected plasma samples from a study that had a two- group cross-sectional design in which main comparisons were with medically...controls. Approach Metabolomic analysis will be performed on pre -collected plasma samples from a study that had a two- group cross-sectional design in...disturbances, and health. Metabolomic analysis will be performed on pre -collected plasma samples from a study that had a two- group cross-sectional

  8. Use of vitamin B12 in joint lavage for determination of dilution factors of canine synovial fluid.

    PubMed

    de Bruin, Tanya; de Rooster, Hilde; van Bree, Henri; Cox, Eric

    2005-11-01

    To test a modified saline (0.9% NaCl) solution joint washing (lavage) technique that includes the use of vitamin B12 as an internal marker for the evaluation of synovial fluid dilution in lavage samples from canine joints. 9 plasma samples obtained from blood samples of 9 healthy dogs and 9 synovial fluid samples aspirated from stifle joints of 9 cadaveric dogs. Photometric absorbances of 25% vitamin B12 solution, canine synovial fluid, and canine plasma were measured in a spectrophotometer to establish an optimal wavelength for analysis. Canine synovial fluid and plasma samples were mixed with the 25% vitamin B12 solution to obtain 1%, 3%, 5%, 10%, 20%, and 50% solutions of synovial fluid or plasma. Diluted synovial fluid and plasma samples were used to simulate joint lavage samples and to examine the possible interference of these substances (synovial fluid or plasma) with the absorbance of the 25% vitamin B12 solution in photometric analysis. The optimal wavelength was found to be at 550 nm. Canine synovial fluid and plasma samples did not interfere with the absorbance measurements of the 25% vitamin B12 solution up to a 50% dilution of plasma or synovial fluid. The modified saline solution joint lavage method with the use of a 25% vitamin B12 solution as an internal standard provides an accurate and reliable technique for the evaluation of synovial fluid dilution in lavage samples from canine joints.

  9. Multiplex picodroplet digital PCR to detect KRAS mutations in circulating DNA from the plasma of colorectal cancer patients.

    PubMed

    Taly, Valerie; Pekin, Deniz; Benhaim, Leonor; Kotsopoulos, Steve K; Le Corre, Delphine; Li, Xinyu; Atochin, Ivan; Link, Darren R; Griffiths, Andrew D; Pallier, Karine; Blons, Hélène; Bouché, Olivier; Landi, Bruno; Hutchison, J Brian; Laurent-Puig, Pierre

    2013-12-01

    Multiplex digital PCR (dPCR) enables noninvasive and sensitive detection of circulating tumor DNA with performance unachievable by current molecular-detection approaches. Furthermore, picodroplet dPCR facilitates simultaneous screening for multiple mutations from the same sample. We investigated the utility of multiplex dPCR to screen for the 7 most common mutations in codons 12 and 13 of the KRAS (Kirsten rat sarcoma viral oncogene homolog) oncogene from plasma samples of patients with metastatic colorectal cancer. Fifty plasma samples were tested from patients for whom the primary tumor biopsy tissue DNA had been characterized by quantitative PCR. Tumor characterization revealed that 19 patient tumors had KRAS mutations. Multiplex dPCR analysis of the plasma DNA prepared from these samples identified 14 samples that matched the mutation identified in the tumor, 1 sample contained a different KRAS mutation, and 4 samples had no detectable mutation. Among the tumor samples that were wild type for KRAS, 2 KRAS mutations were identified in the corresponding plasma samples. Duplex dPCR (i.e., wild-type and single-mutation assay) was also used to analyze plasma samples from patients with KRAS-mutated tumors and 5 samples expected to contain the BRAF (v-raf murine sarcoma viral oncogene homolog B) V600E mutation. The results for the duplex analysis matched those for the multiplex analysis for KRAS-mutated samples and, owing to its higher sensitivity, enabled detection of 2 additional samples with low levels of KRAS-mutated DNA. All 5 samples with BRAF mutations were detected. This work demonstrates the clinical utility of multiplex dPCR to screen for multiple mutations simultaneously with a sensitivity sufficient to detect mutations in circulating DNA obtained by noninvasive blood collection.

  10. Quantitative, multiplexed workflow for deep analysis of human blood plasma and biomarker discovery by mass spectrometry.

    PubMed

    Keshishian, Hasmik; Burgess, Michael W; Specht, Harrison; Wallace, Luke; Clauser, Karl R; Gillette, Michael A; Carr, Steven A

    2017-08-01

    Proteomic characterization of blood plasma is of central importance to clinical proteomics and particularly to biomarker discovery studies. The vast dynamic range and high complexity of the plasma proteome have, however, proven to be serious challenges and have often led to unacceptable tradeoffs between depth of coverage and sample throughput. We present an optimized sample-processing pipeline for analysis of the human plasma proteome that provides greatly increased depth of detection, improved quantitative precision and much higher sample analysis throughput as compared with prior methods. The process includes abundant protein depletion, isobaric labeling at the peptide level for multiplexed relative quantification and ultra-high-performance liquid chromatography coupled to accurate-mass, high-resolution tandem mass spectrometry analysis of peptides fractionated off-line by basic pH reversed-phase (bRP) chromatography. The overall reproducibility of the process, including immunoaffinity depletion, is high, with a process replicate coefficient of variation (CV) of <12%. Using isobaric tags for relative and absolute quantitation (iTRAQ) 4-plex, >4,500 proteins are detected and quantified per patient sample on average, with two or more peptides per protein and starting from as little as 200 μl of plasma. The approach can be multiplexed up to 10-plex using tandem mass tags (TMT) reagents, further increasing throughput, albeit with some decrease in the number of proteins quantified. In addition, we provide a rapid protocol for analysis of nonfractionated depleted plasma samples analyzed in 10-plex. This provides ∼600 quantified proteins for each of the ten samples in ∼5 h of instrument time.

  11. Dried blood spot analysis for therapeutic drug monitoring of pazopanib.

    PubMed

    de Wit, Djoeke; den Hartigh, Jan; Gelderblom, Hans; Qian, Yanwen; den Hollander, Margret; Verheul, Henk; Guchelaar, Henk-Jan; van Erp, Nielka P

    2015-12-01

    Dried blood spot (DBS) sampling is potentially a more patient-friendly and flexible alternative to venous sampling of pazopanib. This study determined the agreement between pazopanib DBS and plasma concentrations to facilitate implementation of pazopanib DBS sampling into clinical practice. Paired DBS and plasma samples were collected in 12 patients. Pazopanib plasma concentrations were calculated from DBS concentrations using the formula: plasma concentration = DBSconcentration /(1 - hematocrit). Passing-Bablok and Bland-Altman analyses were used to determine the agreement between calculated and measured plasma concentrations. We predefined a clinical acceptance limit of 25% for the Bland-Altman analysis. Passing-Bablok analysis showed a small constant (intercept estimate, -8.53 [95%CI, -12.22 to -4.41]) and slightly proportional (slope estimate, 1.15 [95%CI, 1.04-1.24]) bias between calculated and measured concentrations. This bias was clinically nonrelevant, as shown by Bland-Altman analysis; the mean ratio of calculated to measured concentrations was 0.94 (95%CI, 0.65-1.23). The clinical acceptance limits were well within these 95% limits of agreement. More specifically, 92.6% of the data points were within the predefined acceptance limits. Pazopanib plasma concentrations can be accurately calculated from DBS concentrations. Although validation of DBS cards prepared by patients themselves is required, these results show that DBS sampling can be used to monitor pazopanib therapy in clinical practice. © 2015, The American College of Clinical Pharmacology.

  12. A liquid chromatography/tandem mass spectrometry assay for the analysis of atomoxetine in human plasma and in vitro cellular samples

    PubMed Central

    Appel, David I.; Brinda, Bryan; Markowitz, John S.; Newcorn, Jeffrey H.; Zhu, Hao-Jie

    2012-01-01

    A simple, rapid and sensitive method for quantification of atomoxetine by liquid chromatography- tandem mass spectrometry (LC-MS/MS) was developed. This assay represents the first LC-MS/MS quantification method for atomoxetine utilizing electrospray ionization. Deuterated atomoxetine (d3-atomoxetine) was adopted as the internal standard. Direct protein precipitation was utilized for sample preparation. This method was validated for both human plasma and in vitro cellular samples. The lower limit of quantification was 3 ng/ml and 10 nM for human plasma and cellular samples, respectively. The calibration curves were linear within the ranges of 3 ng/ml to 900 ng/ml and 10 nM to 10 μM for human plasma and cellular samples, respectively (r2 > 0.999). The intra- and inter-day assay accuracy and precision were evaluated using quality control samples at 3 different concentrations in both human plasma and cellular lysate. Sample run stability, assay selectivity, matrix effect, and recovery were also successfully demonstrated. The present assay is superior to previously published LC-MS and LC-MS/MS methods in terms of sensitivity or the simplicity of sample preparation. This assay is applicable to the analysis of atomoxetine in both human plasma and in vitro cellular samples. PMID:22275222

  13. Avian plasma chemistry analysis using diluted samples.

    PubMed

    Waldoch, Jennifer; Wack, Raymund; Christopher, Mary

    2009-12-01

    Clinical chemistry tests are essential for the diagnosis and monitoring of disease in birds. The small volume of blood that can be obtained from many avian species limits the use of routine in-house chemistry analyzers. The aim of this study was to examine the accuracy and precision of avian plasma chemistry values obtained by use of a benchtop analyzer in samples diluted with sterile water, as compared with undiluted samples. Whole blood samples were collected from 13 clinically healthy thick-billed parrots (Rhynchopsitta pachyrhyncha). The samples were placed in lithium heparin tubes and centrifuged and the plasma decanted. One aliquot was analyzed immediately using a VetScan benchtop analyzer with an avian-reptile-specific rotor that included 12 analytes. The remainder of the plasma was divided into two aliquots and stored at -80 degrees C until analysis. One of these aliquots was diluted 1:1, 1:1.5, 1:2, and 1:2.5 with sterile water to give final dilutions of 1:2, 1:2.5, 1:3, and 1:3.5, respectively. The other aliquot was pooled with the 12 other samples to create a plasma pool. The undiluted plasma pool and two final dilutions (1:2 and 1:3) of the pooled plasma were analyzed in replicate (n = 20) to determine intra- and interassay imprecision. Each dilution was analyzed using the avian-reptile rotor and the results multiplied by the appropriate dilution factor to obtain the final result. Significant differences were observed in clinical chemistry results obtained from diluted plasma samples for all analytes except aspartate aminotransferase, creatine kinase, and glucose. Uric acid concentration was not significantly different at dilutions of up to 1:3. Bile acids, globulins, and sodium concentrations were below the limit of detection in all diluted samples and were not statistically analyzed. Based on these results, dilution with sterile water is not recommended for biochemical analysis of avian plasma using the VetScan benchtop analyzer.

  14. Influence of the collection tube on metabolomic changes in serum and plasma.

    PubMed

    López-Bascón, M A; Priego-Capote, F; Peralbo-Molina, A; Calderón-Santiago, M; Luque de Castro, M D

    2016-04-01

    Major threats in metabolomics clinical research are biases in sampling and preparation of biological samples. Bias in sample collection is a frequently forgotten aspect responsible for uncontrolled errors in metabolomics analysis. There is a great diversity of blood collection tubes for sampling serum or plasma, which are widely used in metabolomics analysis. Most of the existing studies dealing with the influence of blood collection on metabolomics analysis have been restricted to comparison between plasma and serum. However, polymeric gel tubes, which are frequently proposed to accelerate the separation of serum and plasma, have not been studied. In the present research, samples of serum or plasma collected in polymeric gel tubes were compared with those taken in conventional tubes from a metabolomics perspective using an untargeted GC-TOF/MS approach. The main differences between serum and plasma collected in conventional tubes affected to critical pathways such as the citric acid cycle, metabolism of amino acids, fructose and mannose metabolism and that of glycerolipids, and pentose and glucuronate interconversion. On the other hand, the polymeric gel only promoted differences at the metabolite level in serum since no critical differences were observed between plasma collected with EDTA tubes and polymeric gel tubes. Thus, the main changes were attributable to serum collected in gel and affected to the metabolism of amino acids such as alanine, proline and threonine, the glycerolipids metabolism, and two primary metabolites such as aconitic acid and lactic acid. Therefore, these metabolite changes should be taken into account in planning an experimental protocol for metabolomics analysis. Copyright © 2016 Elsevier B.V. All rights reserved.

  15. Programmable calculator software for computation of the plasma binding of ligands.

    PubMed

    Conner, D P; Rocci, M L; Larijani, G E

    1986-01-01

    The computation of the extent of plasma binding of a ligand to plasma constituents using radiolabeled ligand and equilibrium dialysis is complex and tedious. A computer program for the HP-41C Handheld Computer Series (Hewlett-Packard) was developed to perform these calculations. The first segment of the program constructs a standard curve for quench correction of post-dialysis plasma and buffer samples, using either external standard ratio (ESR) or sample channels ratio (SCR) techniques. The remainder of the program uses the counts per minute, SCR or ESR, and post-dialysis volume of paired plasma and buffer samples generated from the dialysis procedure to compute the extent of binding after correction for background radiation, counting efficiency, and intradialytic shifts of fluid between plasma and buffer compartments during dialysis. This program greatly simplifies the analysis of equilibrium dialysis data and has been employed in the analysis of dexamethasone binding in normal and uremic sera.

  16. Cracks and nanodroplets produced on tungsten surface samples by dense plasma jets

    NASA Astrophysics Data System (ADS)

    Ticoş, C. M.; Galaţanu, M.; Galaţanu, A.; Luculescu, C.; Scurtu, A.; Udrea, N.; Ticoş, D.; Dumitru, M.

    2018-03-01

    Small samples of 12.5 mm in diameter made from pure tungsten were exposed to a dense plasma jet produced by a coaxial plasma gun operated at 2 kJ. The surface of the samples was analyzed using a scanning electron microscope (SEM) before and after applying consecutive plasma shots. Cracks and craters were produced in the surface due to surface tensions during plasma heating. Nanodroplets and micron size droplets could be observed on the samples surface. An energy-dispersive spectroscopy (EDS) analysis revealed that the composition of these droplets coincided with that of the gun electrode material. Four types of samples were prepared by spark plasma sintering from powders with the average particle size ranging from 70 nanometers up to 80 μm. The plasma power load to the sample surface was estimated to be ≈4.7 MJ m-2 s-1/2 per shot. The electron temperature and density in the plasma jet had peak values 17 eV and 1.6 × 1022 m-3, respectively.

  17. Comparison of biochemical values in serum and plasma, fresh and frozen plasma, and hemolyzed samples from orange-winged Amazon parrots (Amazona amazonica).

    PubMed

    Hawkins, Michelle G; Kass, Philip H; Zinkl, Joseph G; Tell, Lisa A

    2006-06-01

    To the authors' knowledge, on the basis of sample type, storage condition, or hemolysis, differences in serum and plasma biochemical values have not been evaluated in orange-winged Amazon parrots (Amazona amazonica). The purpose of this study was to compare values for biochemical analytes in serum vs plasma, fresh vs frozen plasma, and nonhemolyzed vs hemolyzed samples in orange-winged Amazon parrots. We also compared differences in serum and plasma yield from whole-blood aliquots. Fifteen biochemical analytes were evaluated in paired serum and plasma, fresh and frozen plasma, nonhemolyzed and hemolyzed serum and plasma samples from orange-winged Amazon parrots (n = 10) using a wet reagent analyzer. Hemolysis was assessed qualitatively (visually) and quantitatively (hemoglobin [Hgb] measured spectrophotometrically). Serum and plasma yields from 500-microl whole-blood aliquots were determined from centrifuged samples. Analyte values significantly differed among sample groups, but were still within published reference intervals, with the exception of increases in potassium concentration in markedly hemolyzed serum and plasma samples. Clinically important changes in hemolyzed serum and plasma samples included increases in potassium, phosphorus, and albumin concentrations and lactate dehydrogenase activity. The degree of hemolysis assigned qualitatively did not correlate with quantitative Hgb concentration. A significantly greater yield of plasma (288 +/- 13 microL) than serum (241 +/- 44 microL) was obtained. Significant differences may occur in different sample types, however, only changes in potassium, phosphorus, albumin, and lactate dehydrogenase values in hemolyzed samples were considered clinically relevant. Lack of agreement between qualitative and quantitative Hgb concentration indicates the unreliability of visual estimation. Based on higher sample yield, and lack of clinically relevant differences from serum, plasma is a better sample choice for clinical chemistry analysis in birds.

  18. Analysis of ECs and related compounds in plasma: artifactual isomerization and ex vivo enzymatic generation of 2-MGs.

    PubMed

    Pastor, Antoni; Farré, Magí; Fitó, Montserrat; Fernandez-Aranda, Fernando; de la Torre, Rafael

    2014-05-01

    The analysis of peripheral endocannabinoids (ECs) is a good biomarker of the EC system. Their concentrations, from clinical studies, strongly depend on sample collection and time processing conditions taking place in clinical and laboratory settings. The analysis of 2-monoacylglycerols (MGs) (i.e., 2-arachidonoylglycerol or 2-oleoylglycerol) is a particularly challenging issue because of their ex vivo formation and chemical isomerization that occur after blood sample collection. We provide evidence that their ex vivo formation can be minimized by adding Orlistat, an enzymatic lipase inhibitor, to plasma. Taking into consideration the low cost of Orlistat, we recommend its addition to plasma collecting tubes while maintaining sample cold chain until storage. We have validated a method for the determination of the EC profile of a range of MGs and N-acylethanolamides in plasma that preserves the original isomer ratio of MGs. Nevertheless, the chemical isomerization of 2-MGs can only be avoided by an immediate processing and analysis of samples due to their instability during conservation. We believe that this new methodology can aid in the harmonization of the measurement of ECs and related compounds in clinical samples.

  19. Laser induced breakdown spectroscopy (LIBS) as a rapid tool for material analysis

    NASA Astrophysics Data System (ADS)

    Hussain, T.; Gondal, M. A.

    2013-06-01

    Laser induced breakdown spectroscopy (LIBS) is a novel technique for elemental analysis based on laser-generated plasma. In this technique, laser pulses are applied for ablation of the sample, resulting in the vaporization and ionization of sample in hot plasma which is finally analyzed by the spectrometer. The elements are identified by their unique spectral signatures. LIBS system was developed for elemental analysis of solid and liquid samples. The developed system was applied for qualitative as well as quantitative measurement of elemental concentration present in iron slag and open pit ore samples. The plasma was generated by focusing a pulsed Nd:YAG laser at 1064 nm on test samples to study the capabilities of LIBS as a rapid tool for material analysis. The concentrations of various elements of environmental significance such as cadmium, calcium, magnesium, chromium, manganese, titanium, barium, phosphorus, copper, iron, zinc etc., in these samples were determined. Optimal experimental conditions were evaluated for improving the sensitivity of developed LIBS system through parametric dependence study. The laser-induced breakdown spectroscopy (LIBS) results were compared with the results obtained using standard analytical technique such as inductively couple plasma emission spectroscopy (ICP). Limit of detection (LOD) of our LIBS system were also estimated for the above mentioned elements. This study demonstrates that LIBS could be highly appropriate for rapid online analysis of iron slag and open pit waste.

  20. Comparison of plasma ctDNA and tissue/cytology-based techniques for the detection of EGFR mutation status in advanced NSCLC: Spanish data subset from ASSESS.

    PubMed

    Arriola, E; Paredes-Lario, A; García-Gomez, R; Diz-Tain, P; Constenla, M; García-Girón, C; Márquez, G; Reck, M; López-Vivanco, G

    2018-04-05

    The analysis of epidermal growth factor receptor (EGFR) mutations in many patients with advanced non-small-cell lung cancer (aNSCLC) has provided the opportunity for successful treatment with specific, targeted EGFR tyrosine kinase inhibitors. However, this therapeutic decision may be challenging when insufficient tumor tissue is available for EGFR mutation testing. Therefore, blood surrogate samples for EGFR mutation analysis have been suggested. Data were collected from the Spanish cohort of patients in the large, non-interventional, diagnostic ASSESS study (NCT01785888) evaluating the utility of circulating free tumor-derived DNA from plasma for EGFR mutation testing. The incidence of EGFR mutation in Spain and the level of concordance between matched tissue/cytology and plasma samples were evaluated. In a cohort of 154 eligible patients, EGFR mutations were identified in 15.1 and 11.0% of tumor and plasma samples, respectively. The most commonly used EGFR mutation testing method for the tumor tissue samples was the QIAGEN Therascreen ® EGFR RGQ PCR kit (52.1%). Fragment Length Analysis + PNA LNA Clamp was used for the plasma samples. The concordance rate for EGFR mutation status between the tissue/cytology and plasma samples was 88.8%; the sensitivity was 45.5%, and the specificity was 96.7%. The high concordance between the different DNA sources for EGFR mutation testing supports the use of plasma samples when tumor tissue is unavailable.

  1. Qualitative and quantitative spectro-chemical analysis of dates using UV-pulsed laser induced breakdown spectroscopy and inductively coupled plasma mass spectrometry.

    PubMed

    Mehder, A O; Habibullah, Y B; Gondal, M A; Baig, Umair

    2016-08-01

    Laser Induced Breakdown Spectroscopy (LIBS) is demonstrated for the spectral analysis of nutritional and toxic elements present in several varieties of date fruit samples available in the Saudi Arabia market. The method analyzes the optical emission of a test sample when subjected to pulsed laser ablation. In this demonstration, our primary focus is on calcium (Ca) and magnesium (Mg), as nutritional elements, and on chromium (Cr), as a toxic element. The local thermodynamic equilibrium (LTE) condition was confirmed prior to the elemental characterization of date samples to ensure accuracy of the LIBS analysis. This was achieved by measuring parameters associated with the plasma, such as the electron temperature and the electron number density. These plasma parameters aid interpretation of processes such as ionization, dissociation, and excitation occurring in the plasma plume formed by ablating the date palm sample. The minimum detection limit was established from calibration curves that involved plotting the LIBS signal intensity as a function of standard date samples with known concentrations. The concentration of Ca and Mg detected in different varieties of date samples was between 187 and 515 and 35-196mgL(-1) respectively, while Cr concentration measured between 1.72 and 7.76mgL(-1). In order to optimize our LIBS system, we have studied how the LIBS signal intensity depends on the incident laser energy and the delay time. In order to validate our LIBS analysis results, standard techniques such as inductively coupled plasma mass spectrometry (ICP-MS) were also applied on an identical (duplicate) date samples as those used for the LIBS analysis. The LIBS results exhibit remarkable agreement with those obtained from the ICP-MS analysis. In addition, the finger print wavelengths of other elements present in date samples were also identified and are reported here, which has not been previously reported, to the best of our knowledge. Copyright © 2016 Elsevier B.V. All rights reserved.

  2. Whole blood analysis rotor assembly having removable cellular sedimentation bowl

    DOEpatents

    Burtis, C.A.; Johnson, W.F.

    1975-08-26

    A rotor assembly for performing photometric analyses using whole blood samples is described. Following static loading of a gross blood sample within a centrally located, removable, cell sedimentation bowl, the red blood cells in the gross sample are centrifugally separated from the plasma, the plasm displaced from the sedimentation bowl, and measured subvolumes of plasma distributed to respective sample analysis cuvettes positioned in an annular array about the rotor periphery. Means for adding reagents to the respective cuvettes are also described. (auth)

  3. Porous Silicon Antibody Microarrays for Quantitative Analysis: Measurement of Free and Total PSA in Clinical Plasma Samples

    PubMed Central

    Tojo, Axel; Malm, Johan; Marko-Varga, György; Lilja, Hans; Laurell, Thomas

    2014-01-01

    The antibody microarrays have become widespread, but their use for quantitative analyses in clinical samples has not yet been established. We investigated an immunoassay based on nanoporous silicon antibody microarrays for quantification of total prostate-specific-antigen (PSA) in 80 clinical plasma samples, and provide quantitative data from a duplex microarray assay that simultaneously quantifies free and total PSA in plasma. To further develop the assay the porous silicon chips was placed into a standard 96-well microtiter plate for higher throughput analysis. The samples analyzed by this quantitative microarray were 80 plasma samples obtained from men undergoing clinical PSA testing (dynamic range: 0.14-44ng/ml, LOD: 0.14ng/ml). The second dataset, measuring free PSA (dynamic range: 0.40-74.9ng/ml, LOD: 0.47ng/ml) and total PSA (dynamic range: 0.87-295ng/ml, LOD: 0.76ng/ml), was also obtained from the clinical routine. The reference for the quantification was a commercially available assay, the ProStatus PSA Free/Total DELFIA. In an analysis of 80 plasma samples the microarray platform performs well across the range of total PSA levels. This assay might have the potential to substitute for the large-scale microtiter plate format in diagnostic applications. The duplex assay paves the way for a future quantitative multiplex assay, which analyses several prostate cancer biomarkers simultaneously. PMID:22921878

  4. GC-MS and LC-MS analysis of nerve agents in body fluids: intra-laboratory verification test using spiked plasma and urine samples.

    PubMed

    Koller, Marianne; Becker, Christian; Thiermann, Horst; Worek, Franz

    2010-05-15

    The purpose of this study was to check the applicability of different analytical methods for the identification of unknown nerve agents in human body fluids. Plasma and urine samples were spiked with nerve agents (plasma) or with their metabolites (urine) or were left blank. Seven random samples (35% of all samples) were selected for the verification test. Plasma was worked up for unchanged nerve agents and for regenerated nerve agents after fluoride-induced reactivation of nerve agent-inhibited butyrylcholinesterase. Both extracts were analysed by GC-MS. Metabolites were extracted from plasma and urine, respectively, and were analysed by LC-MS. The urinary metabolites and two blank samples could be identified without further measurements, plasma metabolites and blanks were identified in six of seven samples. The analysis of unchanged nerve agent provided five agents/blanks and the sixth agent after further investigation. The determination of the regenerated agents also provided only five clear findings during the first screening because of a rather noisy baseline. Therefore, the sample preparation was extended by a size exclusion step performed before addition of fluoride which visibly reduced baseline noise and thus improved identification of the two missing agents. The test clearly showed that verification should be performed by analysing more than one biomarker to ensure identification of the agent(s). Copyright (c) 2010 Elsevier B.V. All rights reserved.

  5. Methods for detecting and correcting inaccurate results in inductively coupled plasma-atomic emission spectrometry

    DOEpatents

    Chan, George C. Y. [Bloomington, IN; Hieftje, Gary M [Bloomington, IN

    2010-08-03

    A method for detecting and correcting inaccurate results in inductively coupled plasma-atomic emission spectrometry (ICP-AES). ICP-AES analysis is performed across a plurality of selected locations in the plasma on an unknown sample, collecting the light intensity at one or more selected wavelengths of one or more sought-for analytes, creating a first dataset. The first dataset is then calibrated with a calibration dataset creating a calibrated first dataset curve. If the calibrated first dataset curve has a variability along the location within the plasma for a selected wavelength, errors are present. Plasma-related errors are then corrected by diluting the unknown sample and performing the same ICP-AES analysis on the diluted unknown sample creating a calibrated second dataset curve (accounting for the dilution) for the one or more sought-for analytes. The cross-over point of the calibrated dataset curves yields the corrected value (free from plasma related errors) for each sought-for analyte.

  6. In-Depth, Reproducible Analysis of Human Plasma Using IgY 14 and SuperMix Immunodepletion.

    PubMed

    Beer, Lynn A; Ky, Bonnie; Barnhart, Kurt T; Speicher, David W

    2017-01-01

    Identification of cancer and other disease biomarkers in human plasma has been exceptionally challenging due to the complex nature of plasma and the presence of a moderate number of high- and medium-abundance proteins which mask low-abundance proteins of interest. As a result, immunoaffinity depletion formats combining multiple antibodies to target the most abundant plasma proteins have become the first stage in most plasma proteome discovery schemes. This protocol describes the use of tandem IgY 14 and SuperMix immunoaffinity depletion to reproducibly remove >99% of total plasma protein. This greatly increases the depth of analysis of human plasma proteomes. Depleted plasma samples can then be analyzed in a single high-resolution LC-MS/MS run on a Q Exactive Plus mass spectrometer, followed by label-free quantitation. If greater depth of analysis is desired, the depleted plasma can be further fractionated by separating the sample for a short distance on a 1D SDS gel and cutting the gel into uniform slices prior to trypsin digestion. Alternatively, the depleted plasma can be reduced, alkylated, and digested with trypsin followed by high-pH reversed-phase HPLC separation.

  7. Quantitative analysis of titanium concentration using calibration-free laser-induced breakdown spectroscopy (LIBS)

    NASA Astrophysics Data System (ADS)

    Zaitun; Prasetyo, S.; Suliyanti, M. M.; Isnaeni; Herbani, Y.

    2018-03-01

    Laser-induced breakdown spectroscopy (LIBS) can be used for quantitative and qualitative analysis. Calibration-free LIBS (CF-LIBS) is a method to quantitatively analyze concentration of elements in a sample in local thermodynamic equilibrium conditions without using available matrix-matched calibration. In this study, we apply CF-LIBS for quantitative analysis of Ti in TiO2 sample. TiO2 powder sample was mixed with polyvinyl alcohol and formed into pellets. An Nd:YAG pulsed laser at a wavelength of 1064 nm was focused onto the sample to generate plasma. The spectrum of plasma was recorded using spectrophotometer then compared to NIST spectral line to determine energy levels and other parameters. The value of plasma temperature obtained using Boltzmann plot is 8127.29 K and electron density from calculation is 2.49×1016 cm-3. Finally, the concentration of Ti in TiO2 sample from this study is 97% that is in proximity with the sample certificate.

  8. Determination of benzocaine in rainbow trout plasma

    USGS Publications Warehouse

    Bernardy, Jeffery A.; Coleman, K.S.; Stehly, G.R.; Gingerich, William H.

    1996-01-01

    A liquid chromatographic method is described for analysis of benzocaine (BZ), a proposed fish anesthetic, in rainbow trout plasma, Mean recoveries of BZ from plasma samples fortified at 44-10 100 ng/mL were 96-100%. The method detection limit is 10 ng/mL, and the limit of quantitation is 37 ng/mL. Acetylation of BZ occurs in whole blood after storage at room temperature (i.e., 21 degrees C) for 10 min. However, no acetylation of BZ was detected in plasma samples held at room temperature for 4 h, Mean method precision for plasma samples with incurred BZ residue is similar to that for fortified samples in the same concentration range (relative standard deviations of 0.9 and 1.2%, respectively).

  9. Ameliorating effects of Mango (Mangifera indica L.) fruit on plasma ethanol level in a mouse model assessed with 1H-NMR based metabolic profiling

    PubMed Central

    Kim, So-Hyun; K. Cho, Somi; Min, Tae-Sun; Kim, Yujin; Yang, Seung-Ok; Kim, Hee-Su; Hyun, Sun-Hee; Kim, Hana; Kim, Young-Suk; Choi, Hyung-Kyoon

    2011-01-01

    The ameliorating effects of Mango (Mangifera indica L.) flesh and peel samples on plasma ethanol level were investigated using a mouse model. Mango fruit samples remarkably decreased mouse plasma ethanol levels and increased the activities of alcohol dehydrogenase and acetaldehyde dehydrogenase. The 1H-NMR-based metabolomic technique was employed to investigate the differences in metabolic profiles of mango fruits, and mouse plasma samples fed with mango fruit samples. The partial least squares-discriminate analysis of 1H-NMR spectral data of mouse plasma demonstrated that there were clear separations among plasma samples from mice fed with buffer, mango flesh and peel. A loading plot demonstrated that metabolites from mango fruit, such as fructose and aspartate, might stimulate alcohol degradation enzymes. This study suggests that mango flesh and peel could be used as resources for functional foods intended to decrease plasma ethanol level after ethanol uptake. PMID:21562641

  10. NS3 protease resistance-associated substitutions in liver tissue and plasma samples from patients infected by hepatitis C virus genotype 1A or 1B.

    PubMed

    Morsica, Giulia; Andolina, Andrea; Merli, Marco; Messina, Emanuela; Hasson, Hamid; Lazzarin, Adriano; Uberti-Foppa, Caterina; Bagaglio, Sabrina

    2017-08-01

    The presence of naturally occurring resistance-associated substitutions (RASs) in the HCV-protease domain has been poorly investigated in the liver, the main site of HCV replication. We evaluated the natural resistance of the virus to NS3 protease inhibitors in liver tissue and plasma samples taken from HCV-infected patients. RASs were investigated by means of viral population sequencing in liver tissue samples from 18 HCV-infected patients harbouring genotype 1a or genotype 1b; plasma samples from 12 of these patients were also available for virological investigation. A discordant genotype was found in two of the 12 patients (16.6%) who provided samples from both compartments. Sequence analysis of the NS3 protease domain showed the presence of RASs in four of the 18 liver tissue samples (22.2%), two of which showed cross-resistance to protease inhibitors in clinical use or phase 2-3 trials. The analysis of the 12 paired tissues and plasma samples excluded the presence of RASs in the plasma compartment. The dominance of discordant genotypes in the paired liver and plasma samples of some HCV-infected patients suggests mixed infection possibly leading to the selective advantage of different genotype in the two compartments. The presence of RASs at intra-hepatic level is not uncommon and may lead to the early emergence of cross-resistant strains.

  11. FT-IR spectroscopy and multivariate analysis as an auxiliary tool for diagnosis of mental disorders: Bipolar and schizophrenia cases

    NASA Astrophysics Data System (ADS)

    Ogruc Ildiz, G.; Arslan, M.; Unsalan, O.; Araujo-Andrade, C.; Kurt, E.; Karatepe, H. T.; Yilmaz, A.; Yalcinkaya, O. B.; Herken, H.

    2016-01-01

    In this study, a methodology based on Fourier-transform infrared spectroscopy and principal component analysis and partial least square methods is proposed for the analysis of blood plasma samples in order to identify spectral changes correlated with some biomarkers associated with schizophrenia and bipolarity. Our main goal was to use the spectral information for the calibration of statistical models to discriminate and classify blood plasma samples belonging to bipolar and schizophrenic patients. IR spectra of 30 samples of blood plasma obtained from each, bipolar and schizophrenic patients and healthy control group were collected. The results obtained from principal component analysis (PCA) show a clear discrimination between the bipolar (BP), schizophrenic (SZ) and control group' (CG) blood samples that also give possibility to identify three main regions that show the major differences correlated with both mental disorders (biomarkers). Furthermore, a model for the classification of the blood samples was calibrated using partial least square discriminant analysis (PLS-DA), allowing the correct classification of BP, SZ and CG samples. The results obtained applying this methodology suggest that it can be used as a complimentary diagnostic tool for the detection and discrimination of these mental diseases.

  12. Dependence of LTX plasma performance on surface conditions as determined by in situ analysis of plasma facing components

    NASA Astrophysics Data System (ADS)

    Lucia, M.; Kaita, R.; Majeski, R.; Bedoya, F.; Allain, J. P.; Abrams, T.; Bell, R. E.; Boyle, D. P.; Jaworski, M. A.; Schmitt, J. C.

    2015-08-01

    The Materials Analysis and Particle Probe (MAPP) diagnostic has been implemented on the Lithium Tokamak Experiment (LTX) at PPPL, providing the first in situ X-ray photoelectron spectroscopy (XPS) surface characterization of tokamak plasma facing components (PFCs). MAPP samples were exposed to argon glow discharge conditioning (GDC), lithium evaporations, and hydrogen tokamak discharges inside LTX. Samples were analyzed with XPS, and alterations to surface conditions were correlated against observed LTX plasma performance changes. Argon GDC caused the accumulation of nm-scale metal oxide layers on the PFC surface, which appeared to bury surface carbon and oxygen contamination and thus improve plasma performance. Lithium evaporation led to the rapid formation of a lithium oxide (Li2O) surface; plasma performance was strongly improved for sufficiently thick evaporative coatings. Results indicate that a 5 h argon GDC or a 50 nm evaporative lithium coating will both significantly improve LTX plasma performance.

  13. FLOCK cluster analysis of plasma cell flow cytometry data predicts bone marrow involvement by plasma cell neoplasia.

    PubMed

    Dorfman, David M; LaPlante, Charlotte D; Li, Betty

    2016-09-01

    We analyzed plasma cell populations in bone marrow samples from 353 patients with possible bone marrow involvement by a plasma cell neoplasm, using FLOCK (FLOw Clustering without K), an unbiased, automated, computational approach to identify cell subsets in multidimensional flow cytometry data. FLOCK identified discrete plasma cell populations in the majority of bone marrow specimens found by standard histologic and immunophenotypic criteria to be involved by a plasma cell neoplasm (202/208 cases; 97%), including 34 cases that were negative by standard flow cytometric analysis that included clonality assessment. FLOCK identified discrete plasma cell populations in only a minority of cases negative for involvement by a plasma cell neoplasm by standard histologic and immunophenotypic criteria (38/145 cases; 26%). Interestingly, 55% of the cases negative by standard analysis, but containing a FLOCK-identified discrete plasma cell population, were positive for monoclonal gammopathy by serum protein electrophoresis and immunofixation. FLOCK-identified and quantitated plasma cell populations accounted for 3.05% of total cells on average in cases positive for involvement by a plasma cell neoplasm by standard histologic and immunophenotypic criteria, and 0.27% of total cells on average in cases negative for involvement by a plasma cell neoplasm by standard histologic and immunophenotypic criteria (p<0.0001; area under the curve by ROC analysis=0.96). The presence of a FLOCK-identified discrete plasma cell population was predictive of the presence of plasma cell neoplasia with a sensitivity of 97%, compared with only 81% for standard flow cytometric analysis, and had specificity of 74%, PPV of 84% and NPV of 95%. FLOCK analysis, which has been shown to provide useful diagnostic information for evaluating patients with suspected systemic mastocytosis, is able to identify neoplastic plasma cell populations analyzed by flow cytometry, and may be helpful in the diagnostic evaluation of bone marrow samples for involvement by plasma cell neoplasia. Copyright © 2016 Elsevier Ltd. All rights reserved.

  14. LIBS: a potential tool for industrial/agricultural waste water analysis

    NASA Astrophysics Data System (ADS)

    Karpate, Tanvi; K. M., Muhammed Shameem; Nayak, Rajesh; V. K., Unnikrishnan; Santhosh, C.

    2016-04-01

    Laser Induced Breakdown Spectroscopy (LIBS) is a multi-elemental analysis technique with various advantages and has the ability to detect any element in real time. This technique holds a potential for environmental monitoring and various such analysis has been done in soil, glass, paint, water, plastic etc confirms the robustness of this technique for such applications. Compared to the currently available water quality monitoring methods and techniques, LIBS has several advantages, viz. no need for sample preparation, fast and easy operation, and chemical free during the process. In LIBS, powerful pulsed laser generates plasma which is then analyzed to get quantitative and qualitative details of the elements present in the sample. Another main advantage of LIBS technique is that it can perform in standoff mode for real time analysis. Water samples from industries and agricultural strata tend to have a lot of pollutants making it harmful for consumption. The emphasis of this project is to determine such harmful pollutants present in trace amounts in industrial and agricultural wastewater. When high intensity laser is made incident on the sample, a plasma is generated which gives a multielemental emission spectra. LIBS analysis has shown outstanding success for solids samples. For liquid samples, the analysis is challenging as the liquid sample has the chances of splashing due to the high energy of laser and thus making it difficult to generate plasma. This project also deals with determining the most efficient method for testing of water sample for qualitative as well as quantitative analysis using LIBS.

  15. Peptidomic analysis of endogenous plasma peptides from patients with pancreatic neuroendocrine tumours.

    PubMed

    Kay, Richard G; Challis, Benjamin G; Casey, Ruth T; Roberts, Geoffrey P; Meek, Claire L; Reimann, Frank; Gribble, Fiona M

    2018-06-01

    Diagnosis of pancreatic neuroendocrine tumours requires the study of patient plasma with multiple immunoassays, using multiple aliquots of plasma. The application of mass spectrometry based techniques could reduce the cost and amount of plasma required for diagnosis. Plasma samples from two patients with pancreatic neuroendocrine tumours were extracted using an established acetonitrile based plasma peptide enrichment strategy. The circulating peptidome was characterised using nano and high flow rate LC/MS analyses. To assess the diagnostic potential of the analytical approach, a large sample batch (68 plasmas) from control subjects, and aliquots from subjects harbouring two different types of pancreatic neuroendocrine tumour (insulinoma and glucagonoma) were analysed using a 10-minute LC/MS peptide screen. The untargeted plasma peptidomics approach identified peptides derived from the glucagon prohormone, chromogranin A, chromogranin B and other peptide hormones and proteins related to control of peptide secretion. The glucagon prohormone derived peptides that were detected were compared against putative peptides that were identified using multiple antibody pairs against glucagon peptides. Comparison of the plasma samples for relative levels of selected peptides showed clear separation between the glucagonoma and the insulinoma and control samples. The combination of the organic solvent extraction methodology with high flow rate analysis could potentially be used to aid diagnosis and monitor treatment of patients with functioning pancreatic neuroendocrine tumours. However, significant validation will be required before this approach can be clinically applied. This article is protected by copyright. All rights reserved.

  16. Effect of catalyst on deposition of vanadium oxide in plasma ambient

    NASA Astrophysics Data System (ADS)

    Singh, Megha; Kumar, Prabhat; Saini, Sujit K.; Reddy, G. B.

    2018-05-01

    In this paper, we have studied effect of catalyst (buffer layer) on structure, morphology, crystallinity, uniformity of nanostructured thin films deposited in nitrogen plasma ambient keeping all other process parameters constant. The process used for deposition is novel known as Plasma Assisted Sublimation Process (PASP). Samples were then studied using SEM, TEM, HRTEM, Raman spectroscopy. By structural analysis it was found out that samples deposited on Ni layer composed chiefly of α-V2O5 but minor amount of other phases were present in the sample. Samples deposited on Al catalyst layer revealed different phase of V2O5, where sample deposited on Ag was composed chiefly of VO2±x phase. Further analysis revealed that morphology of samples is also affected by catalyst. While samples deposited in Al and Ag layer tend to have reasonably defined geometry, sample deposited on Ni layer were irregular in shape and size. All the results well corroborate with each other.

  17. Analysis of structural transformation in wool fiber resulting from oxygen plasma treatment using vibrational spectroscopy

    NASA Astrophysics Data System (ADS)

    Barani, Hossein; Haji, Aminoddin

    2015-01-01

    The aim of this study was to investigate the influence of oxygen plasma procedure at different time treatments on wool fiber using the micro-Raman spectroscopy as a non-destructive vibrational spectroscopic technique and Fourier transform infrared spectroscopy. The amide I and III regions, Csbnd C skeletal vibration region, and Ssbnd S and Csbnd S bonds vibration regions were analyzed with the Raman microscope. The Fourier transform infrared spectroscope analysis was employed to find out the effect of oxygen plasma treatment on the cysteic acid residues content of the wool fiber sample. The results indicated that the α-helix structure was the highest component content of wool fiber. Moreover, the protein secondary structure of wool fibers was transformed from α-helical arrangement to the β-pleated sheet configuration during the oxygen plasma treatment. Also, the disulphide bonds content in the treated wool fiber reduced because they were fractured and oxidized during oxygen plasma treatment. The oxygen plasma treated samples presented higher cysteic acid compared to the untreated wool samples due to produce more cleavage of disulfide linkages.

  18. Non‐Thermal Plasma in Contact with Water: The Origin of Species

    PubMed Central

    Gorbanev, Yury

    2016-01-01

    Abstract Non‐thermal atmospheric pressure plasma has attracted considerable attention in recent years due to its potential for biomedical applications. Determining the mechanism of the formation of reactive species in liquid treated with plasma is thus of paramount importance for both fundamental and applied research. In this work, the origin of reactive species in plasma‐treated aqueous solutions was investigated by using spin‐trapping, hydrogen and oxygen isotopic labelling and electron paramagnetic resonance (EPR) spectroscopy. The species originating from molecules in the liquid phase and those introduced with the feed gas were differentiated by EPR and 1H NMR analysis of liquid samples. The effects of water vapour and oxygen admixtures in the feed gas were investigated. All the reactive species detected in the liquid samples were shown to be formed largely in the plasma gas phase. It is suggested that hydrogen peroxide (determined by UV/Vis analysis) is formed primarily in the plasma tube, whereas the radical species ⋅OOH, ⋅OH and ⋅H are proposed to originate from the region between the plasma nozzle and the liquid sample. PMID:26833560

  19. Digital PCR analysis of plasma cell-free DNA for non-invasive detection of drug resistance mechanisms in EGFR mutant NSCLC: Correlation with paired tumor samples

    PubMed Central

    Ishii, Hidenobu; Azuma, Koichi; Sakai, Kazuko; Kawahara, Akihiko; Yamada, Kazuhiko; Tokito, Takaaki; Okamoto, Isamu; Nishio, Kazuto; Hoshino, Tomoaki

    2015-01-01

    As the development of resistance to epidermal growth factor receptor (EGFR) tyrosine kinase inhibitors (TKIs) has become an issue of concern, identification of the mechanisms responsible has become an urgent priority. However, for research purposes, it is not easy to obtain tumor samples from patients with EGFR mutation-positive non-small-cell lung cancer (NSCLC) that has relapsed after treatment with EGFR-TKIs. Here, using digital PCR assay as an alternative and noninvasive method, we examined plasma and tumor samples from patients with relapsed NSCLC to establish the inter-relationships existing among T790M mutation, activating EGFR mutations, HER2 amplification, and MET amplification. Paired samples of tumor and blood were obtained from a total of 18 patients with NSCLC after they had developed resistance to EGFR-TKI treatment, and the mechanisms of resistance were analyzed by digital PCR. Digital PCR analysis of T790M mutation in plasma had a sensitivity of 81.8% and specificity of 85.7%, the overall concordance between plasma and tissue samples being 83.3%. MET gene copy number gain in tumor DNA was observed by digital PCR in three patients, of whom one exhibited positivity for MET amplification by FISH, whereas no patient demonstrated MET and HER2 copy number gain in plasma DNA. Digital PCR analysis of plasma is feasible and accurate for detection of T790M mutation in NSCLC that becomes resistant to treatment with EGFR-TKIs. PMID:26334838

  20. Non-Thermal Plasma in Contact with Water: The Origin of Species.

    PubMed

    Gorbanev, Yury; O'Connell, Deborah; Chechik, Victor

    2016-03-01

    Non-thermal atmospheric pressure plasma has attracted considerable attention in recent years due to its potential for biomedical applications. Determining the mechanism of the formation of reactive species in liquid treated with plasma is thus of paramount importance for both fundamental and applied research. In this work, the origin of reactive species in plasma-treated aqueous solutions was investigated by using spin-trapping, hydrogen and oxygen isotopic labelling and electron paramagnetic resonance (EPR) spectroscopy. The species originating from molecules in the liquid phase and those introduced with the feed gas were differentiated by EPR and 1 H NMR analysis of liquid samples. The effects of water vapour and oxygen admixtures in the feed gas were investigated. All the reactive species detected in the liquid samples were shown to be formed largely in the plasma gas phase. It is suggested that hydrogen peroxide (determined by UV/Vis analysis) is formed primarily in the plasma tube, whereas the radical species ⋅OOH, ⋅OH and ⋅H are proposed to originate from the region between the plasma nozzle and the liquid sample. © 2016 The Authors. Published by Wiley-VCH Verlag GmbH & Co. KGaA.

  1. Traumatic Hemothorax Blood Contains Elevated Levels of Microparticles that are Prothrombotic but Inhibit Platelet Aggregation.

    PubMed

    Mitchell, Thomas A; Herzig, Maryanne C; Fedyk, Chriselda G; Salhanick, Marc A; Henderson, Aaron T; Parida, Bijaya K; Prat, Nicolas J; Dent, Daniel L; Schwacha, Martin G; Cap, Andrew P

    2017-06-01

    Autotransfusion of shed blood from traumatic hemothorax is an attractive option for resuscitation of trauma patients in austere environments. However, previous analyses revealed that shed hemothorax (HX) blood is defibrinated, thrombocytopenic, and contains elevated levels of D-dimer. Mixing studies with normal pooled plasma demonstrated hypercoagulability, evoking concern for potentiation of acute traumatic coagulopathy. We hypothesized that induction of coagulopathic changes by shed HX blood may be due to increases in cellular microparticles (MP) and that these may also affect recipient platelet function. Shed HX blood was obtained from 17 adult trauma patients under an Institutional Review Board approved prospective observational protocol. Blood samples were collected every hour up to 4 h after thoracostomy tube placement. The corresponding plasma was isolated and frozen for analysis. The effects of shed HX frozen plasma (HFP) and isolated HX microparticles (HMP) on coagulation and platelet function were assessed through mixing studies with platelet-rich plasma at various dilutions followed by analysis with thromboelastometry (ROTEM), platelet aggregometry (Multiplate), enzyme-linked immunosorbent assays, and flow cytometry. Furthermore, HFP was assessed for von Willebrand factor antigen levels and multimer content, and plasma-free hemoglobin. ROTEM analysis demonstrated that diluted HFP and isolated HMP samples decreased clotting time, clotting formation time, and increased α angle, irrespective of sample concentrations, when compared with diluted control plasma. Isolated HMP inhibited platelet aggregation in response to adenosine diphosphate, arachidonic acid, and collagen. HFP contained elevated levels of fibrin-degradation products and tissue factor compared with control fresh frozen plasma samples. MP concentrations in HFP were significantly increased and enriched in events positive for phosphatidylserine, tissue factor, CD235, CD45, CD41a, and CD14. von Willebrand factor (vWF) multimer analysis revealed significant loss of high molecular weight multimers in HFP samples. Plasma-free hemoglobin levels were 8-fold higher in HFP compared with fresh frozen plasma. HFP induces plasma hypercoagulability that is likely related to increased tissue factor and phosphatidylserine expression originating from cell-derived MP. In contrast, platelet dysfunction is induced by HMP, potentially aggravated by depletion of high molecular weight multimers of vWF. Thus, autologous transfusion of shed traumatic hemothorax blood may induce a range of undesirable effects in patients with acute traumatic coagulopathy.

  2. MRM validation of targeted nonglycosylated peptides from N-glycoprotein biomarkers using direct trypsin digestion of undepleted human plasma.

    PubMed

    Lee, Ju Yeon; Kim, Jin Young; Cheon, Mi Hee; Park, Gun Wook; Ahn, Yeong Hee; Moon, Myeong Hee; Yoo, Jong Shin

    2014-02-26

    A rapid, simple, and reproducible MRM-based validation method for serological glycoprotein biomarkers in clinical use was developed by targeting the nonglycosylated tryptic peptides adjacent to N-glycosylation sites. Since changes in protein glycosylation are known to be associated with a variety of diseases, glycoproteins have been major targets in biomarker discovery. We previously found that nonglycosylated tryptic peptides adjacent to N-glycosylation sites differed in concentration between normal and hepatocellular carcinoma (HCC) plasma due to differences in steric hindrance of the glycan moiety in N-glycoproteins to tryptic digestion (Lee et al., 2011). To increase the feasibility and applicability of clinical validation of biomarker candidates (nonglycosylated tryptic peptides), we developed a method to effectively monitor nonglycosylated tryptic peptides from a large number of plasma samples and to reduce the total analysis time with maximizing the effect of steric hindrance by the glycans during digestion of glycoproteins. The AUC values of targeted nonglycosylated tryptic peptides were excellent (0.955 for GQYCYELDEK, 0.880 for FEDGVLDPDYPR and 0.907 for TEDTIFLR), indicating that these could be effective biomarkers for hepatocellular carcinoma. This method provides the necessary throughput required to validate glycoprotein biomarkers, as well as quantitative accuracy for human plasma analysis, and should be amenable to clinical use. Difficulties in verifying and validating putative protein biomarkers are often caused by complex sample preparation procedures required to determine their concentrations in a large number of plasma samples. To solve the difficulties, we developed MRM-based protein biomarker assays that greatly reduce complex, time-consuming, and less reproducible sample pretreatment steps in plasma for clinical implementation. First, we used undepleted human plasma samples without any enrichment procedures. Using nanoLC/MS/MS, we targeted nonglycosylated tryptic peptides adjacent to N-linked glycosylation sites in N-linked glycoprotein biomarkers, which could be detected in human plasma samples without depleting highly abundant proteins. Second, human plasma proteins were digested with trypsin without reduction and alkylation procedures to minimize sample preparation. Third, trypsin digestion times were shortened so as to obtain reproducible results with maximization of the steric hindrance effect of the glycans during enzyme digestion. Finally, this rapid and simple sample preparation method was applied to validate targeted nonglycosylated tryptic peptides as liver cancer biomarker candidates for diagnosis in 40 normal and 41 hepatocellular carcinoma (HCC) human plasma samples. This strategy provided the necessary throughput required to monitor protein biomarkers, as well as quantitative accuracy in human plasma analysis. From biomarker discovery to clinical implementation, our method will provide a biomarker study platform that is suitable for clinical deployment, and can be applied to high-throughput approaches. Copyright © 2014 Elsevier B.V. All rights reserved.

  3. Effects of fusion relevant transient energetic radiation, plasma and thermal load on PLANSEE double forged tungsten samples in a low-energy plasma focus device

    NASA Astrophysics Data System (ADS)

    Javadi, S.; Ouyang, B.; Zhang, Z.; Ghoranneviss, M.; Salar Elahi, A.; Rawat, R. S.

    2018-06-01

    Tungsten is the leading candidate for plasma facing component (PFC) material for thermonuclear fusion reactors and various efforts are ongoing to evaluate its performance or response to intense fusion relevant radiation, plasma and thermal loads. This paper investigates the effects of hot dense decaying pinch plasma, highly energetic deuterium ions and fusion neutrons generated in a low-energy (3.0 kJ) plasma focus device on the structure, morphology and hardness of the PLANSEE double forged tungsten (W) samples surfaces. The tungsten samples were provided by Forschungszentrum Juelich (FZJ), Germany via International Atomic Energy Agency, Vienna, Austria. Tungsten samples were irradiated using different number of plasma focus (PF) shots (1, 5 and 10) at a fixed axial distance of 5 cm from the anode top and also at various distances from the top of the anode (5, 7, 9 and 11 cm) using fixed number (5) of plasma focus shots. The virgin tungsten sample had bcc structure (α-W phase). After PF irradiation, the XRD analysis showed (i) the presence of low intensity new diffraction peak corresponding to β-W phase at (211) crystalline plane indicating the partial structural phase transition in some of the samples, (ii) partial amorphization, and (iii) vacancy defects formation and compressive stress in irradiated tungsten samples. Field emission scanning electron microscopy showed the distinctive changes to non-uniform surface with nanometer sized particles and particle agglomerates along with large surface cracks at higher number of irradiation shots. X-ray photoelectron spectroscopy analysis demonstrated the reduction in relative tungsten oxide content and the increase in metallic tungsten after irradiation. Hardness of irradiated samples initially increased for one shot exposure due to reduction in tungsten oxide phase, but then decreased with increasing number of shots due to increasing concentration of defects. It is demonstrated that the plasma focus device provides appropriate intense fusion relevant pulses for testing the structural, morphological and mechanical changes on irradiated tungsten samples.

  4. Three-phase double-arc plasma for spectrochemical analysis of environmental samples.

    PubMed

    Mohamed, M M; Ghatass, Z F; Shalaby, E A; Kotb, M M; El-Raey, M

    2000-12-01

    A new instrument, which uses a three-phase current to support a double-arc argon plasma torch for evaporation, atomization and excitation of solid or powder samples, is described. The sampling arc is ignited between the first and second electrode while the excitation arc is ignited between the second and third electrode. Aerosol generated from the sample (first electrode) is swept by argon gas, through a hole in the second electrode (carbon tubing electrode), into the excitation plasma. A tangential stream of argon gas is introduced through an inlet orifice as a coolant gas for the second electrode. This gas stream forces the excitation arc discharge to rotate reproducibly around the electrode surface. Discharge rotation increases the stability of the excitation plasma. Spectroscopic measurements are made directly in the current-carrying region of the excitation arc. An evaluation of each parameter influencing the device performance was performed. Analytical calibration curves were obtained for Fe, Al, K, and Pb. Finally, the present technique was applied for the analysis of environmental samples. The present method appears to have significant, low cost analytical utility for environmental measurements.

  5. Optical spectroscopy of laser-produced plasmas for standoff isotopic analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Harilal, Sivanandan S.; Brumfield, Brian E.; LaHaye, Nicole L.

    2018-04-20

    This review article covers the present status of isotope detection through emission, absorption, and fluorescence spectroscopy of atoms and molecules in a laser-produced plasma formed from a solid sample. A description of the physics behind isotope shifts in atoms and molecules is presented, followed by the physics behind solid sampling of laser ablation plumes, optical methods for isotope measurements, the suitable physical conditions of laser-produced plasma plumes for isotopic analysis, and the current status. Finally, concluding remarks will be made on the existing gaps between previous works in the literature and suggestions for future work.

  6. Optical spectroscopy of laser-produced plasmas for standoff isotopic analysis

    DOE PAGES

    Harilal, S. S.; Brumfield, B. E.; LaHaye, N. L.; ...

    2018-04-20

    This review article covers the present status of isotope detection through emission, absorption, and fluorescence spectroscopy of atoms and molecules in a laser-produced plasma formed from a solid sample. A description of the physics behind isotope shifts in atoms and molecules is presented, followed by the physics behind solid sampling of laser ablation plumes, optical methods for isotope measurements, the suitable physical conditions of laser-produced plasma plumes for isotopic analysis, and the current status. Lastly, concluding remarks will be made on the existing gaps between previous works in the literature and suggestions for future work.

  7. Optical spectroscopy of laser-produced plasmas for standoff isotopic analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Harilal, S. S.; Brumfield, B. E.; LaHaye, N. L.

    This review article covers the present status of isotope detection through emission, absorption, and fluorescence spectroscopy of atoms and molecules in a laser-produced plasma formed from a solid sample. A description of the physics behind isotope shifts in atoms and molecules is presented, followed by the physics behind solid sampling of laser ablation plumes, optical methods for isotope measurements, the suitable physical conditions of laser-produced plasma plumes for isotopic analysis, and the current status. Finally, concluding remarks will be made on the existing gaps between previous works in the literature and suggestions for future work.

  8. Optical spectroscopy of laser-produced plasmas for standoff isotopic analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Harilal, S. S.; Brumfield, B. E.; LaHaye, N. L.

    This review article covers the present status of isotope detection through emission, absorption, and fluorescence spectroscopy of atoms and molecules in a laser-produced plasma formed from a solid sample. A description of the physics behind isotope shifts in atoms and molecules is presented, followed by the physics behind solid sampling of laser ablation plumes, optical methods for isotope measurements, the suitable physical conditions of laser-produced plasma plumes for isotopic analysis, and the current status. Lastly, concluding remarks will be made on the existing gaps between previous works in the literature and suggestions for future work.

  9. Optical spectroscopy of laser-produced plasmas for standoff isotopic analysis

    DOE PAGES

    Harilal, S. S.; Brumfield, B. E.; LaHaye, N. L.; ...

    2018-06-01

    This review article covers the present status of isotope detection through emission, absorption, and fluorescence spectroscopy of atoms and molecules in a laser-produced plasma formed from a solid sample. A description of the physics behind isotope shifts in atoms and molecules is presented, followed by the physics behind solid sampling of laser ablation plumes, optical methods for isotope measurements, the suitable physical conditions of laser-produced plasma plumes for isotopic analysis, and the current status. Finally, concluding remarks will be made on the existing gaps between previous works in the literature and suggestions for future work.

  10. Analysis of human plasma proteins: a focus on sample collection and separation using free-flow electrophoresis.

    PubMed

    Nissum, Mikkel; Foucher, Aude L

    2008-08-01

    Due to ease of accessibility, plasma has become the sample of choice for proteomics studies directed towards biomarker discovery intended for use in diagnostics, prognostics and even in theranostics. The result of these extensive efforts is a long list of potential biomarkers, very few of which have led to clinical utility. Why have so many potential biomarkers failed validation? Herein, we address certain issues encountered, which complicate biomarker discovery efforts originating from plasma. The advantages of stabilizing the sample at collection by the addition of protease inhibitors are discussed. The principles of free-flow electrophoresis (FFE) separation are provided together with examples applying to various studies. Finally, particular attention is given to plasma or serum analysis using multidimensional separation strategies into which the FFE is incorporated. The advantages of using FFE separation in these workflows are discussed.

  11. Quantification and clinical application of carboplatin in plasma ultrafiltrate.

    PubMed

    Downing, Kim; Jensen, Berit Packert; Grant, Sue; Strother, Matthew; George, Peter

    2017-05-10

    Carboplatin is a chemotherapy drug used in a variety of cancers with the primary toxicity being exposure-dependant myelosuppression. We present the development and validation of a simple, robust inductively coupled plasma mass spectrometry (ICP-MS) method to measure carboplatin in plasma ultrafiltrate. Plasma ultrafiltrates samples were prepared using Amicon Ultra 30,000da cut-off filters and then diluted with ammonia EDTA before ICP-MS analysis. The assay was validated in the range 0.19-47.5mg/L carboplatin in ultrafiltrate. The assay was linear (r 2 >0.9999), accurate (<6% bias, 12% bias at LLOQ) and precise (intra- and inter-day precision of <3% coefficient of variation). No matrix effects were observed between plasma ultrafiltrate and aqueous platinum calibrators and recovery was complete. The assay was applied to 10 clinical samples from patients receiving carboplatin. Incurred sample reanalysis showed reproducible values over 3 analysis days (<6% CV). As plasma stability prior to ultrafiltration has been a major concern in previous clinical studies this was studied extensively at room temperature (22°C) over 24h. Carboplatin was found to be stable in both spiked plasma (n=3) and real patient samples (n=10) at room temperature for up to 8h before ultrafiltration. This makes routine measurement of carboplatin concentrations in clinical settings feasible. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. Gunshot residue (GSR) analysis by single particle inductively coupled plasma mass spectrometry (spICP-MS).

    PubMed

    Heringer, Rodrigo D; Ranville, James F

    2018-05-25

    Single particle inductively coupled plasma mass spectrometry (spICP-MS) was investigated as a screening-level technique for the analysis and characterization of inorganic gunshot residue (IGSR) nanoparticles. spICP-MS works with undigested samples whereby nanoparticles (NPs) in a suspension are individually atomized and ionized as they reach the plasma, each resulting in a pulse of analyte ions that can be quantified. The method is rapid, and signals from hundreds of NPs can be collected in 1-2min per sample. The technique is quantitative for NP mass and number concentration when only one element (single element mode) is measured using a quadrupole MS. Likewise, a qualitative elemental fingerprint can be obtained for individual NPs when peak-hopping between two elements (dual element mode). For this proof of concept study, each shooter's hand was sampled with ultrapure water or swab to obtain NPs suspensions. Measurements of antimony, barium, and lead were performed using both analysis modes. With no sample preparation and fully automated sample introduction, it is possible to analyze more than 100 samples in a day. Results show that this technique opens a new perspective for future research on GSR sample identification and characterization and can complement SEM/EDX analysis. Copyright © 2018 Elsevier B.V. All rights reserved.

  13. A simple and sensitive method for determining plasma cell isotype and monoclonality in bone marrow using flowcytometry.

    PubMed

    van Zaanen, H C; Vet, R J; de Jong, C M; von dem Borne, A E; van Oers, M H

    1995-09-01

    In this paper we describe a new, rapid and sensitive method to determine plasma cell isotype and clonality in bone marrow using flowcytometry. With the use of a new fixation and permeabilization reagent (Permeafix), which preserves cell structure and morphology, and a monoclonal antibody (Mab) specific for plasma cells (B-B4), it has become possible to specifically select plasma cells and to determine the cytoplasmatic immunoglobulins by flowcytometry. Thirty successive bone marrow aspirates from multiple myeloma patients and patients with MGUS were studied as well as 10 bone marrow samples from patients with reactive plasmacytosis. Each sample was analysed both by immunofluorescence on cytospin smears and FACS analysis. There were no discrepancies between plasma cell isotype as determined by FACS and cytospin. Moreover, FACS analysis was shown to allow detection of very low numbers of plasma cells and to determine whether these plasma cells are mono- or polyclonal. Possible applications are discussed.

  14. Plasma-surface modification vs air oxidation on carbon obtained from peach stone: Textural and chemical changes and the efficiency as adsorbents

    NASA Astrophysics Data System (ADS)

    De Velasco Maldonado, Paola S.; Hernández-Montoya, Virginia; Montes-Morán, Miguel A.

    2016-10-01

    Carbons were prepared from peach stones (Prunus persica) using different carbonization temperatures (600, 800 and 1000 °C). A selected sample was modified by oxidation using conventional oxidation techniques (thermal treatment in air atmosphere) and with cold oxygen plasma oxidation, under different conditions. Samples were characterized using elemental analysis, FT-IR spectroscopy, nitrogen adsorption isotherms at -196 °C, SEM/EDX analysis, potentiometric titration and XPS analysis. Carbons with and without oxidation were employed in the adsorption of Pb2+ in aqueous solution. Results obtained indicated that the materials with high contents of acidic oxygen groups were more efficient in the removal of Pb2+, values as high as approx. 40 mg g-1 being obtained for the best performing carbon. Textural properties of the original, un-oxidized carbon were significantly altered only after oxidation under air atmosphere at 450 °C. On the other hand, the samples oxidized with plasma show little changes in the textural parameters and a slight increase in the specific surface was observed for the sample treated at high RF power (100 W). Additionally, a significant increment of the oxygen content was observed for the plasma oxidized samples, as measured by XPS.

  15. Integrated analytical approach in veal calves administered the anabolic androgenic steroids boldenone and boldione: urine and plasma kinetic profile and changes in plasma protein expression.

    PubMed

    Draisci, Rosa; Montesissa, Clara; Santamaria, Barbara; D'Ambrosio, Chiara; Ferretti, Giovanni; Merlanti, Roberta; Ferranti, Carolina; De Liguoro, Marco; Cartoni, Claudia; Pistarino, Erika; Ferrara, Lino; Tiso, Micaela; Scaloni, Andrea; Cosulich, M Elisabetta

    2007-09-01

    Surveillance of illegal use of steroids hormones in cattle breeding is a key issue to preserve human health. To this purpose, an integrated approach has been developed for the analysis of plasma and urine from calves treated orally with a single dose of a combination of the androgenic steroids boldenone and boldione. A quantitative estimation of steroid hormones was obtained by LC-APCI-Q-MS/MS analysis of plasma and urine samples obtained at various times up to 36 and 24 h after treatment, respectively. These experiments demonstrated that boldione was never found, while boldenone alpha- and beta-epimers were detected in plasma and urine only within 2 and 24 h after drug administration, respectively. Parallel proteomic analysis of plasma samples was obtained by combined 2-DE, MALDI-TOF-MS and muLC-ESI-IT-MS/MS procedures. A specific protein, poorly represented in normal plasma samples collected before treatment, was found upregulated even 36 h after hormone treatment. Extensive mass mapping experiments proved this component as an N-terminal truncated form of apolipoprotein A1 (ApoA1), a protein involved in cholesterol transport. The expression profile of ApoA1 analysed by Western blot analysis confirmed a significant and time dependent increase of this ApoA1 fragment. Then, provided that further experiments performed with a growth-promoting schedule will confirm these preliminary findings, truncated ApoA1 may be proposed as a candidate biomarker for steroid boldenone and possibly other anabolic androgens misuse in cattle veal calves, when no traces of hormones are detectable in plasma or urine.

  16. Quantitative analysis of aberrant protein glycosylation in liver cancer plasma by AAL-enrichment and MRM mass spectrometry.

    PubMed

    Ahn, Yeong Hee; Shin, Park Min; Kim, Yong-Sam; Oh, Na Ree; Ji, Eun Sun; Kim, Kwang Hoe; Lee, Yeon Jung; Kim, Sung Ho; Yoo, Jong Shin

    2013-11-07

    A lectin-coupled mass spectrometry (MS) approach was employed to quantitatively monitor aberrant protein glycosylation in liver cancer plasma. To do this, we compared the difference in the total protein abundance of a target glycoprotein between hepatocellular carcinoma (HCC) plasmas and hepatitis B virus (HBV) plasmas, as well as the difference in lectin-specific protein glycoform abundance of the target glycoprotein. Capturing the lectin-specific protein glycoforms from a plasma sample was accomplished by using a fucose-specific aleuria aurantia lectin (AAL) immobilized onto magnetic beads via a biotin-streptavidin conjugate. Following tryptic digestion of both the total plasma and its AAL-captured fraction of each HCC and HBV sample, targeted proteomic mass spectrometry was conducted quantitatively by a multiple reaction monitoring (MRM) technique. From the MRM-based analysis of the total plasmas and AAL-captured fractions, differences between HCC and HBV plasma groups in fucosylated glycoform levels of target glycoproteins were confirmed to arise from both the change in the total protein abundance of the target proteins and the change incurred by aberrant fucosylation on target glycoproteins in HCC plasma, even when no significant change occurs in the total protein abundance level. Combining the MRM-based analysis method with the lectin-capturing technique proved to be a successful means of quantitatively investigating aberrant protein glycosylation in cancer plasma samples. Additionally, it was elucidated that the differences between HCC and control groups in fucosylated biomarker candidates A1AT and FETUA mainly originated from an increase in fucosylation levels on these target glycoproteins, rather than an increase in the total protein abundance of the target glycoproteins.

  17. Application of Plackett-Burman and Doehlert designs for optimization of selenium analysis in plasma with electrothermal atomic absorption spectrometry.

    PubMed

    El Ati-Hellal, Myriam; Hellal, Fayçal; Hedhili, Abderrazek

    2014-10-01

    The aim of this study was the optimization of selenium determination in plasma samples with electrothermal atomic absorption spectrometry using experimental design methodology. 11 variables being able to influence selenium analysis in human blood plasma by electrothermal atomic absorption spectrometry (ETAAS) were evaluated with Plackett-Burman experimental design. These factors were selected from sample preparation, furnace program and chemical modification steps. Both absorbance and background signals were chosen as responses in the screening approach. Doehlert design was used for method optimization. Results showed that only ashing temperature has a statistically significant effect on the selected responses. Optimization with Doehlert design allowed the development of a reliable method for selenium analysis with ETAAS. Samples were diluted 1/10 with 0.05% (v/v) TritonX-100+2.5% (v/v) HNO3 solution. Optimized ashing and atomization temperatures for nickel modifier were 1070°C and 2270°C, respectively. A detection limit of 2.1μgL(-1) Se was obtained. Accuracy of the method was checked by the analysis of selenium in Seronorm™ Trace element quality control serum level 1. The developed procedure was applied for the analysis of total selenium in fifteen plasma samples with standard addition method. Concentrations ranged between 24.4 and 64.6μgL(-1), with a mean of 42.6±4.9μgL(-1). The use of experimental designs allowed the development of a cheap and accurate method for selenium analysis in plasma that could be applied routinely in clinical laboratories. Copyright © 2014 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  18. Fast vaporization solid phase microextraction and ion mobility spectrometry: A new approach for determination of creatinine in biological fluids.

    PubMed

    Jafari, Mostafa; Ebrahimzadeh, Homeira; Banitaba, Mohamma Hossein

    2015-11-01

    In this work a rapid and simple method for creatinine determination in urine and plasma samples based on aqueous derivatization of creatinine and complete vaporization of sample (as low as 10 µL), followed by ion mobility spectrometry analysis has been proposed. The effect of four important parameters (extraction temperature, total volume of solution, desorption temperature and extraction time) on ion mobility signal has been studied. Under the optimized conditions, the quantitative response of ion mobility spectrometry for creatinine was linear in the range of 0-500 mg L(-1) with a detection limit of 0.6 mg L(-1) in urine and 0-250 mg L(-1) with a detection limit of 2.6 mg L(-1) in plasma sample. The limit of quantitation of creatinine was 2.1 mg L(-1) and 8.7 mg L(-1) in urine and plasma samples, respectively. The relative standard deviation of the method was found to be 13%. The method was successfully applied to the analysis of creatinine in biological samples, showing recoveries from 92% to 104% in urine and 101-110% in plasma samples. Copyright © 2015 Elsevier B.V. All rights reserved.

  19. High resolution melting analysis for epidermal growth factor receptor mutations in formalin-fixed paraffin-embedded tissue and plasma free DNA from non-small cell lung cancer patients.

    PubMed

    Jing, Chang-Wen; Wang, Zhuo; Cao, Hai-Xia; Ma, Rong; Wu, Jian-Zhong

    2014-01-01

    The aim of the research was to explore a cost effective, fast, easy to perform, and sensitive method for epidermal growth factor receptor (EGFR) mutation testing. High resolution melting analysis (HRM) was introduced to evaluate the efficacy of the analysis for dectecting EGFR mutations in exons 18 to 21 using formalin-fixed paraffin-embedded (FFPE) tissues and plasma free DNA from 120 patients. The total EGFR mutation rate was 37.5% (45/120) detected by direct sequencing. There were 48 mutations in 120 FFPE tissues assessed by HRM. For plasma free DNA, the EGFR mutation rate was 25.8% (31/120). The sensitivity of HRM assays in FFPE samples was 100% by HRM. There was a low false-positive mutation rate but a high false-negative rate in plasma free DNA detected by HRM. Our results show that HRM analysis has the advantage of small tumor sample need. HRM applied with plasma free DNA showed a high false-negative rate but a low false-positive rate. Further research into appropriate methods and analysis needs to be performed before HRM for plasma free DNA could be accepted as an option in diagnostic or screening settings.

  20. Rapid determination of tafenoquine in small volume human plasma samples by high-performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Doyle, E; Fowles, S E; Summerfield, S; White, T J

    2002-03-25

    A method was developed for the determination of tafenoquine (I) in human plasma using high-performance liquid chromatography-tandem mass spectrometry. Prior to analysis, the protein in plasma samples was precipitated with methanol containing [2H3(15N)]tafenoquine (II) to act as an internal standard. The supernatant was injected onto a Genesis-C18 column without any further clean-up. The mass spectrometer was operated in the positive ion mode, employing a heat assisted nebulisation, electrospray interface. Ions were detected in multiple reaction monitoring mode. The assay required 50 microl of plasma and was precise and accurate within the range 2 to 500 ng/ml. The average within-run and between-run relative standard deviations were < 7% at 2 ng/ml and greater concentrations. The average accuracy of validation standards was generally within +/- 4% of the nominal concentration. There was no evidence of instability of I in human plasma following three complete freeze-thaw cycles and samples can safely be stored for at least 8 months at approximately -70 degrees C. The method was very robust and has been successfully applied to the analysis of clinical samples from patients and healthy volunteers dosed with I.

  1. Effect of storage duration on cytokine stability in human serum and plasma.

    PubMed

    Vincent, Fabien B; Nim, Hieu T; Lee, Jacinta P W; Morand, Eric F; Harris, James

    2018-06-14

    Quantification of analytes such as cytokines in serum samples is intrinsic to translational research in immune diseases. Optimising pre-analytical conditions is critical for ensuring study quality, including evaluation of cytokine stability. We aimed to evaluate the effect on cytokine stability of storage duration prior to freezing of serum, and compare to plasma samples obtained from patients with systemic lupus erythematosus (SLE). Protein stability was analysed by simultaneously quantifying 18 analytes using a custom multi-analyte profile in SLE patient serum and plasma samples that had been prospectively stored at 4 °C for pre-determined periods between 0 and 30 days, prior to freezing. Six analytes were excluded from analysis, because most tested samples were above or below the limit of detection. Amongst the 12 analysed proteins, 11 did not show significant signal degradation. Significant signal degradation was observed from the fourth day of storage for a single analyte, CCL19. Proteins levels were more stable in unseparated serum compared to plasma for most analytes, with the exception of IL-37 which appears slightly more stable in plasma. Based on this, a maximum 3 days of storage at 4 °C for unseparated serum samples is recommended for biobanked samples intended for cytokine analysis in studies of human immune disease. Copyright © 2018 Elsevier Ltd. All rights reserved.

  2. RAS testing of liquid biopsy correlates with the outcome of metastatic colorectal cancer patients treated with first-line FOLFIRI plus cetuximab in the CAPRI-GOIM trial.

    PubMed

    Normanno, N; Esposito Abate, R; Lambiase, M; Forgione, L; Cardone, C; Iannaccone, A; Sacco, A; Rachiglio, A M; Martinelli, E; Rizzi, D; Pisconti, S; Biglietto, M; Bordonaro, R; Troiani, T; Latiano, T P; Giuliani, F; Leo, S; Rinaldi, A; Maiello, E; Ciardiello, F

    2018-01-01

    Liquid biopsy is an alternative to tissue for RAS testing in metastatic colorectal carcinoma (mCRC) patients. Little information is available on the predictive role of liquid biopsy RAS testing in patients treated with first-line anti-EGFR monoclonal antibody-based therapy. In the CAPRI-GOIM trial, 340 KRAS exon-2 wild-type mCRC patients received first-line cetuximab plus FOLFIRI. Tumor samples were retrospectively assessed by next generation sequencing (NGS). Baseline plasma samples were analyzed for KRAS and NRAS mutations using beads, emulsion, amplification, and magnetics digital PCR (BEAMing). Discordant cases were solved by droplet digital PCR (ddPCR) or deep-sequencing. A subgroup of 92 patients with available both NGS data on tumor samples and baseline plasma samples were included in this study. Both NGS analysis of tumor tissue and plasma testing with BEAMing identified RAS mutations in 33/92 patients (35.9%). However, 10 cases were RAS tissue mutant and plasma wild-type, and additional 10 cases were tissue wild-type and plasma mutant, resulting in a concordance rate of 78.3%. Analysis of plasma samples with ddPCR detected RAS mutations in 2/10 tissue mutant, plasma wild-type patients. In contrast, in all tissue wild-type and plasma mutant cases, ddPCR or deep-sequencing analysis of tumor tissue confirmed the presence of RAS mutations at allelic frequencies ranging between 0.15% and 1.15%. The median progression-free survival of RAS mutant and wild-type patients according to tissue (7.9 versus 12.6 months; P = 0.004) and liquid biopsy testing (7.8 versus 13.8 moths; P < 0.001) were comparable. Similar findings were observed for the median overall survival of RAS mutant and wild-type patients based on tissue (22.1 versus 35.8 months; P = 0.016) and plasma (19.9 versus 35.8 months; P = 0.013) analysis. This study indicates that RAS testing of liquid biopsy results in a similar outcome when compared with tissue testing in mCRC patients receiving first-line anti-EGFR monoclonal antibodies. © The Author 2017. Published by Oxford University Press on behalf of the European Society for Medical Oncology. All rights reserved. For permissions, please email: journals.permissions@oup.com.

  3. Gas chromatography--inductively coupled plasma--time-of-flight mass spectrometry for the speciation analysis of organolead compounds in environmental water samples.

    PubMed

    Heisterkamp, M; Adams, F C

    2001-07-01

    The application of inductively coupled plasma--time-of-flight mass spectrometry for the speciation analysis of organolead compounds in environmental waters is described. Construction of the transfer line was achieved by means of a relatively simple and rapid coupling procedure. Derivatization of the ionic lead species was achieved by in-situ propylation with sodium tetrapropylborate; simultaneous extraction of the derivatized compounds in hexane was followed by separation and detection by capillary gas chromatography hyphenated to inductively coupled plasma-time-of-flight mass spectrometry. Detection limits for the different organolead species ranged from 10 to 15 fg (as Pb), corresponding to procedural detection limits between 50 and 75 ng L(-1), on the basis of a 50 mL snow sample, extraction with 200 microL hexane, and subsequent injection of 1 microL of the organic extract on to the column. The accuracy of the system was confirmed by additional analysis of the water samples by capillary gas chromatography coupled with microwave-induced plasma-atomic-emission spectrometry and the analysis of a standard reference material CRM 605 (road dust) with a certified content of trimethyllead.

  4. Tools for phospho- and glycoproteomics of plasma membranes.

    PubMed

    Wiśniewski, Jacek R

    2011-07-01

    Analysis of plasma membrane proteins and their posttranslational modifications is considered as important for identification of disease markers and targets for drug treatment. Due to their insolubility in water, studying of plasma membrane proteins using mass spectrometry has been difficult for a long time. Recent technological developments in sample preparation together with important improvements in mass spectrometric analysis have facilitated analysis of these proteins and their posttranslational modifications. Now, large scale proteomic analyses allow identification of thousands of membrane proteins from minute amounts of sample. Optimized protocols for affinity enrichment of phosphorylated and glycosylated peptides have set new dimensions in the depth of characterization of these posttranslational modifications of plasma membrane proteins. Here, I summarize recent advances in proteomic technology for the characterization of the cell surface proteins and their modifications. In the focus are approaches allowing large scale mapping rather than analytical methods suitable for studying individual proteins or non-complex mixtures.

  5. Methods of Analysis by the U.S. Geological Survey National Water Quality Laboratory - Determination of Elements in Whole-Water Digests Using Inductively Coupled Plasma-Optical Emission Spectrometry and Inductively Coupled Plasma-Mass Spectrometry

    USGS Publications Warehouse

    Garbarino, John R.; Struzeski, Tedmund M.

    1998-01-01

    Inductively coupled plasma-optical emission spectrometry (ICP-OES) and inductively coupled plasma-mass spectrometry (ICP-MS) can be used to determine 26 elements in whole-water digests. Both methods have distinct advantages and disadvantages--ICP-OES is capable of analyzing samples with higher elemental concentrations without dilution, however, ICP-MS is more sensitive and capable of determining much lower elemental concentrations. Both techniques gave accurate results for spike recoveries, digested standard reference-water samples, and whole-water digests. Average spike recoveries in whole-water digests were 100 plus/minus 10 percent, although recoveries for digests with high dissolved-solid concentrations were lower for selected elements by ICP-MS. Results for standard reference-water samples were generally within 1 standard deviation of hte most probable values. Statistical analysis of the results from 43 whole-water digest indicated that there was no significant difference among ICP-OES, ICP-MS, and former official methods of analysis for 24 of the 26 elements evaluated.

  6. Sensitive analysis of blonanserin, a novel antipsychotic agent, in human plasma by ultra-performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Ogawa, Tadashi; Hattori, Hideki; Kaneko, Rina; Ito, Kenjiro; Iwai, Masayo; Mizutani, Yoko; Arinobu, Tetsuya; Ishii, Akira; Suzuki, Osamu; Seno, Hiroshi

    2010-01-01

    A rapid and sensitive method for analysis of blonanserin in human plasma by ultra-performance liquid chromatography-tandem mass spectrometry is presented. After pretreatment of a plasma sample by solid-phase extraction, blonanserin was analyzed by the system with a C(18) column. This method gave satisfactory recovery rates, reproducibility, and good linearity of calibration curve in the range of 0.01-10.0 ng/mL for quality control samples spiked with blonanserin. The detection limit was as low as 1 pg/mL. This method seems very useful in forensic and clinical toxicology and pharmacokinetic studies.

  7. Dynamic molecular analysis and clinical correlates of tumor evolution within a phase II trial of panitumumab-based therapy in metastatic colorectal cancer.

    PubMed

    Siena, S; Sartore-Bianchi, A; Garcia-Carbonero, R; Karthaus, M; Smith, D; Tabernero, J; Van Cutsem, E; Guan, X; Boedigheimer, M; Ang, A; Twomey, B; Bach, B A; Jung, A S; Bardelli, A

    2018-01-01

    Mutations in rat sarcoma (RAS) genes may be a mechanism of secondary resistance in epidermal growth factor receptor inhibitor-treated patients. Tumor-tissue biopsy testing has been the standard for evaluating mutational status; however, plasma testing of cell-free DNA has been shown to be a more sensitive method for detecting clonal evolution. Archival pre- and post-treatment tumor biopsy samples from a phase II study of panitumumab in combination with irinotecan in patients with metastatic colorectal cancer (mCRC) that also collected plasma samples before, during, and after treatment were analyzed for emergence of mutations during/post-treatment by next-generation sequencing and BEAMing. The rate of emergence of tumor tissue RAS mutations was 9.5% by next-generation sequencing (n = 21) and 6.3% by BEAMing (n = 16). Plasma testing of cell-free DNA by BEAMing revealed a mutant RAS emergence rate of 36.7% (n = 39). Exploratory outcomes analysis of plasma samples indicated that patients who had emergent RAS mutations at progression had similar median progression-free survival to those patients who remained wild-type at progression. Serial analysis of plasma samples showed that the first detected emergence of RAS mutations preceded progression by a median of 3.6 months (range, -0.3 to 7.5 months) and that there did not appear to be a mutant RAS allele frequency threshold that could predict near-term outcomes. This first prospective analysis in mCRC showed that serial plasma biopsies are more inclusive than tissue biopsies for evaluating global tumor heterogeneity; however, the clinical utility of plasma testing in mCRC remains to be further explored. NCT00891930. © The Author 2017. Published by Oxford University Press on behalf of the European Society for Medical Oncology.

  8. Low-Molecular-Weight Plasma Proteome Analysis Using Top-Down Mass Spectrometry.

    PubMed

    Cheon, Dong Huey; Yang, Eun Gyeong; Lee, Cheolju; Lee, Ji Eun

    2017-01-01

    While human plasma has a wealth of diagnostic information regarding the state of the human body in heath and disease, low molecular weight (LMW) proteome (<30 kDa) has been shown to contain a rich source of diagnostic biomarkers. Here we describe a protocol for top-down proteomic analysis to identify and characterize the LMW proteoforms present in four types of human plasma samples without immunoaffinity depletion and with depletion of the top two, six, and seven high-abundance proteins. Each type of plasma sample was first fractionated based on molecular weight using gel-eluted liquid fraction entrapment electrophoresis (GELFrEE). Then, the GELFrEE fractions containing up to 30 kDa were subjected to nanocapillary-LC-MS/MS, and the high-resolution MS and MS/MS data were processed using ProSightPC software. As a result, a total of 442 LMW proteins and cleaved products, including those with posttranslational modifications (PTMs) and single amino acid variations (SAAVs), were identified with a threshold E-value of 1 × 10 -4 from the four types of plasma samples.

  9. Mass spectrometric identification of diagnostic markers for chronic prostatitis in seminal plasma by analysis of seminal plasma protein clinical samples.

    PubMed

    Rokka, A; Mehik, A; Tonttila, P; Vaarala, M

    2017-08-15

    There are few specific diagnostic markers for chronic prostatitis. Therefore, we used mass spectrometry to evaluate differences in seminal plasma protein expression among patients with prostatitis and young and middle-aged healthy controls. We analysed pooled seminal plasma protein samples from four prostatitis patients (two pools), three young controls (one pool), and three middle-aged controls (one pool). The samples were analysed by liquid chromatography-tandem mass spectrometry. Of the 349 proteins identified, 16 were differentially expressed between the two control pools. Five proteins were up- or down-regulated in both of the prostatitis pools compared to middle-aged controls but not between young and middle-aged pools. Progestagen-associated endometrial protein (PAEP) was over-expressed in prostatitis samples compared to young and middle-aged controls. Our findings and those of previous studies indicate that PAEP is a potential seminal plasma marker for chronic prostatitis. In conclusion, we found age-related changes in seminal plasma protein expression. PAEP expression in seminal plasma should be investigated further to evaluate its potential as a diagnostic marker for chronic prostatitis.

  10. Mixed-mode ion exchange-based integrated proteomics technology for fast and deep plasma proteome profiling.

    PubMed

    Xue, Lu; Lin, Lin; Zhou, Wenbin; Chen, Wendong; Tang, Jun; Sun, Xiujie; Huang, Peiwu; Tian, Ruijun

    2018-06-09

    Plasma proteome profiling by LC-MS based proteomics has drawn great attention recently for biomarker discovery from blood liquid biopsy. Due to standard multi-step sample preparation could potentially cause plasma protein degradation and analysis variation, integrated proteomics sample preparation technologies became promising solution towards this end. Here, we developed a fully integrated proteomics sample preparation technology for both fast and deep plasma proteome profiling under its native pH. All the sample preparation steps, including protein digestion and two-dimensional fractionation by both mixed-mode ion exchange and high-pH reversed phase mechanism were integrated into one spintip device for the first time. The mixed-mode ion exchange beads design achieved the sample loading at neutral pH and protein digestion within 30 min. Potential sample loss and protein degradation by pH changing could be voided. 1 μL of plasma sample with depletion of high abundant proteins was processed by the developed technology with 12 equally distributed fractions and analyzed with 12 h of LC-MS gradient time, resulting in the identification of 862 proteins. The combination of the Mixed-mode-SISPROT and data-independent MS method achieved fast plasma proteome profiling in 2 h with high identification overlap and quantification precision for a proof-of-concept study of plasma samples from 5 healthy donors. We expect that the Mixed-mode-SISPROT become a generally applicable sample preparation technology for clinical oriented plasma proteome profiling. Copyright © 2018 Elsevier B.V. All rights reserved.

  11. Thermometry of the system “heat-resistant sample - incident plasma stream”

    NASA Astrophysics Data System (ADS)

    Sargsyan, M. A.; Chinnov, V. F.; Kavyrshin, D. I.; Gadzhiev, M. Kh; Khromov, M. A.; Chistolinov, A. V.; Senchenko, V. N.

    2017-11-01

    To study the interacting system “heat-resistant sample - an incident plasma stream” a setup of synchronized measurement equipment was developed and tested that recorded the main parameters of such interaction. Heat resistance tests were carried out on the samples of MPG-6 grade isotropic graphite, and samples of pyrolytic graphite that were subjected to a long (60 … 100 s) exposure to nitrogen, argon and air plasma streams at atmospheric pressure. As plasma generators a series of plasma torches with a vortex stabilization of the stream and an expanding anode channels was used. The temperature and composition of the plasma in the jet and near the sample were determined using two AvaSpec2048 and AvaSpec3648 scanning optical spectrometers and the MS5402i spectrograph with the Andor matrix at its outlet. The surface temperature of the sample was determined in real time using three independent ways: two pyrometric systems - a high-speed micro-pyrometer FMP1001 and a two-position visualization of the heated sample by high-speed Motion Pro X3 and VS-FAST cameras, and the spectral analysis of the wide-range thermal radiation of the samples. The main method for determining the rate of material loss during the action of a plasma jet on it was to analyze a two-position synchronous visualization of the “jet-sample” system. When a crater was formed on the surface of the sample under the “dagger” effect of a plasma jet, a video recording system of the crater zone was used, backlit using the “laser knife” method.

  12. Plasma impregnation of wood with fire retardants

    NASA Astrophysics Data System (ADS)

    Pabeliña, Karel G.; Lumban, Carmencita O.; Ramos, Henry J.

    2012-02-01

    The efficacy of chemical and plasma treatments with phosphate and boric compounds, and nitrogen as flame retardants on wood are compared in this study. The chemical treatment involved the conventional method of spraying the solution over the wood surface at atmospheric condition and chemical vapor deposition in a vacuum chamber. The plasma treatment utilized a dielectric barrier discharge ionizing and decomposing the flame retardants into innocuous simple compounds. Wood samples are immersed in either phosphoric acid, boric acid, hydrogen or nitrogen plasmas or a plasma admixture of two or three compounds at various concentrations and impregnated by the ionized chemical reactants. Chemical changes on the wood samples were analyzed by Fourier transform infrared spectroscopy (FTIR) while the thermal changes through thermo gravimetric analysis (TGA). Plasma-treated samples exhibit superior thermal stability and fire retardant properties in terms of highest onset temperature, temperature of maximum pyrolysis, highest residual char percentage and comparably low total percentage weight loss.

  13. Enhancing analysis throughput, sensitivity and specificity in LC/ESI-MS/MS assay of plasma 25-hydroxyvitamin D3 by derivatization with triplex 4-(4-dimethylaminophenyl)-1,2,4-triazoline-3,5-dione (DAPTAD) isotopologues.

    PubMed

    Ogawa, Shoujiro; Kittaka, Hiroki; Nakata, Akiho; Komatsu, Kenji; Sugiura, Takahiro; Satoh, Mamoru; Nomura, Fumio; Higashi, Tatsuya

    2017-03-20

    The plasma/serum concentration of 25-hydroxyvitamin D 3 [25(OH)D 3 ] is a diagnostic index for vitamin D deficiency/insufficiency, which is associated with a wide range of diseases, such as rickets, cancer and diabetes. We have reported that the derivatization with 4-(4-dimethylaminophenyl)-1,2,4-triazoline-3,5-dione (DAPTAD) works well in the liquid chromatography/electrospray ionization-tandem mass spectrometry (LC/ESI-MS/MS) assay of the serum/plasma 25(OH)D 3 for enhancing the sensitivity and the separation from a potent interfering metabolite, 3-epi-25-hydroxyvitamin D 3 [3-epi-25(OH)D 3 ]. However, enhancing the analysis throughput remains an issue in the LC/ESI-MS/MS assay of 25(OH)D 3 . The most obvious restriction of the LC/MS/MS throughput is the chromatographic run time. In this study, we developed an enhanced throughput method for the determination of the plasma 25(OH)D 3 by LC/ESI-MS/MS combined with the derivatization using the triplex ( 2 H 0 -, 2 H 3 - and 2 H 6 -) DAPTAD isotopologues. After separate derivatization with 1 of 3 different isotopologues, the 3 samples were combined and injected together into LC/ESI-MS/MS. Based on the mass differences between the isotopologues, the derivatized 25(OH)D 3 in the 3 different samples were quantified within a single run. The developed method tripled the hourly analysis throughput without sacrificing assay performance, i.e., ease of pretreatment of plasma sample (only deproteinization), limit of quantification (1.0ng/mL when a 5μL-plasma was used), precision (intra-assay RSD≤5.9% and inter-assay RSD≤5.5%), accuracy (98.7-102.2%), matrix effects, and capability of separating from an interfering metabolite, 3-epi-25(OH)D 3 . The multiplexing of samples by the isotopologue derivatization was applied to the analysis of plasma samples of healthy subjects and the developed method was proven to have a satisfactory applicability. Copyright © 2016 Elsevier B.V. All rights reserved.

  14. MYC protein expression is detected in plasma cell myeloma but not in monoclonal gammopathy of undetermined significance (MGUS).

    PubMed

    Xiao, Ruobing; Cerny, Jan; Devitt, Katherine; Dresser, Karen; Nath, Rajneesh; Ramanathan, Muthalagu; Rodig, Scott J; Chen, Benjamin J; Woda, Bruce A; Yu, Hongbo

    2014-06-01

    It has been recognized that monoclonal gammopathy of undetermined significance (MGUS) precedes a diagnosis of plasma cell myeloma in most patients. Recent gene expression array analysis has revealed that an MYC activation signature is detected in plasma cell myeloma but not in MGUS. In this study, we performed immunohistochemical studies using membrane CD138 and nuclear MYC double staining on bone marrow biopsies from patients who met the diagnostic criteria of plasma cell myeloma or MGUS. Our study demonstrated nuclear MYC expression in CD138-positive plasma cells in 22 of 26 (84%) plasma cell myeloma samples and in none of the 29 bone marrow samples from patients with MGUS. In addition, our data on the follow-up biopsies from plasma cell myeloma patients with high MYC expression demonstrated that evaluation of MYC expression in plasma cells can be useful in detecting residual disease. We also demonstrated that plasma cells gained MYC expression in 5 of 8 patients (62.5%) when progressing from MGUS to plasma cell myeloma. Analysis of additional lymphomas with plasmacytic differentiation, including lymphoplasmacytic lymphoma, marginal zone lymphoma, and plasmablastic lymphoma, reveals that MYC detection can be a useful tool in the diagnosis of plasma cell myeloma.

  15. Preparation and Certification of Two New Bulk Welding Fume Reference Materials for Use in Laboratories Undertaking Analysis of Occupational Hygiene Samples

    PubMed Central

    Butler, Owen; Musgrove, Darren; Stacey, Peter

    2014-01-01

    Workers can be exposed to fume, arising from welding activities, which contain toxic metals and metalloids. Occupational hygienists need to assess and ultimately minimize such exposure risks. The monitoring of the concentration of particles in workplace air is one assessment approach whereby fume, from representative welding activities, is sampled onto a filter and returned to a laboratory for analysis. Inductively coupled plasma-atomic emission spectrometry and inductively coupled plasma-mass spectrometry are generally employed as instrumental techniques of choice for the analysis of such filter samples. An inherent difficulty, however, with inductively coupled plasma-based analytical techniques is that they typically require a sample to be presented for analysis in the form of a solution. The efficiency of the required dissolution step relies heavily upon the skill and experience of the analyst involved. A useful tool in assessing the efficacy of this dissolution step would be the availability and subsequent analysis of welding fume reference materials with stated elemental concentrations and matrices that match as closely as possible the matrix composition of welding fume samples submitted to laboratories for analysis. This article describes work undertaken at the Health and Safety Laboratory to prepare and certify two new bulk welding fume reference materials that can be routinely used by analysts to assess the performance of the digestion procedures they employ in their laboratories. PMID:24499055

  16. Preparation and certification of two new bulk welding fume reference materials for use in laboratories undertaking analysis of occupational hygiene samples.

    PubMed

    Butler, Owen; Musgrove, Darren; Stacey, Peter

    2014-01-01

    Workers can be exposed to fume, arising from welding activities, which contain toxic metals and metalloids. Occupational hygienists need to assess and ultimately minimize such exposure risks. The monitoring of the concentration of particles in workplace air is one assessment approach whereby fume, from representative welding activities, is sampled onto a filter and returned to a laboratory for analysis. Inductively coupled plasma-atomic emission spectrometry and inductively coupled plasma-mass spectrometry are generally employed as instrumental techniques of choice for the analysis of such filter samples. An inherent difficulty, however, with inductively coupled plasma-based analytical techniques is that they typically require a sample to be presented for analysis in the form of a solution. The efficiency of the required dissolution step relies heavily upon the skill and experience of the analyst involved. A useful tool in assessing the efficacy of this dissolution step would be the availability and subsequent analysis of welding fume reference materials with stated elemental concentrations and matrices that match as closely as possible the matrix composition of welding fume samples submitted to laboratories for analysis. This article describes work undertaken at the Health and Safety Laboratory to prepare and certify two new bulk welding fume reference materials that can be routinely used by analysts to assess the performance of the digestion procedures they employ in their laboratories.

  17. Analysis of methyloxime derivatives of intact esters of testosterone and boldenone in equine plasma using ultra high performance liquid chromatography tandem mass spectrometry.

    PubMed

    Gray, Bobby P; Teale, Phil; Pearce, Clive M

    2011-04-01

    Analysis of equine plasma samples to detect the abuse of anabolic steroids can be complicated when the parent steroid is endogenous to the animal. Anabolic steroids are usually administered intramuscularly as synthetic esters and therefore detection of the exogenous esters provides unequivocal proof of illegal administration. An ultra high performance liquid chromatography tandem mass spectrometric (UPLC-MSMS) method for the analysis of esters of testosterone (propionate, phenylpropionate, isocaproate, and decanoate) and boldenone (undecylenate) in equine plasma has been developed. Esters were extracted from equine plasma using a mixture of hexane and ethyl acetate and treated with methoxyamine hydrochloride to form methyloxime derivatives. Metenolone enanthate was used as an internal standard. After chromatographic separation, the derivatized steroid esters were quantified using selected reaction monitoring (SRM). The limit of detection for all of the steroid esters, based on a signal to noise ratio (S/N) of 3:1, was 1-3 pg/mL. The lower limit of quantification (LLOQ) for the all of the steroid esters was 5 pg/mL when 2 mL of plasma was extracted. Recovery of the steroid esters was 85-97% for all esters except for testosterone decanoate which was recovered at 62%. The intra-day coefficient of variation (CV) for the analysis of plasma quality control (QC) samples was less than 9.2% at 40 pg/mL and less than 6.0% at 400 pg/mL. The developed assay was used to successfully confirm the presence of intact testosterone esters in equine plasma samples following intramuscular injection of Durateston® (mixed testosterone esters). Copyright © 2011 John Wiley & Sons, Ltd.

  18. Stable isotope dilution analysis of hydrologic samples by inductively coupled plasma mass spectrometry

    USGS Publications Warehouse

    Garbarino, John R.; Taylor, Howard E.

    1987-01-01

    Inductively coupled plasma mass spectrometry is employed in the determination of Ni, Cu, Sr, Cd, Ba, Ti, and Pb in nonsaline, natural water samples by stable isotope dilution analysis. Hydrologic samples were directly analyzed without any unusual pretreatment. Interference effects related to overlapping isobars, formation of metal oxide and multiply charged ions, and matrix composition were identified and suitable methods of correction evaluated. A comparability study snowed that single-element isotope dilution analysis was only marginally better than sequential multielement isotope dilution analysis. Accuracy and precision of the single-element method were determined on the basis of results obtained for standard reference materials. The instrumental technique was shown to be ideally suited for programs associated with certification of standard reference materials.

  19. NASA GRC and MSFC Space-Plasma Arc Testing Procedures

    NASA Technical Reports Server (NTRS)

    Ferguson, Dale C.; Vayner, Boris V.; Galofaro, Joel T.; Hillard, G. Barry; Vaughn, Jason; Schneider, Todd

    2007-01-01

    Tests of arcing and current collection in simulated space plasma conditions have been performed at the NASA Glenn Research Center (GRC) in Cleveland, Ohio, for over 30 years and at the Marshall Space Flight Center (MSFC) in Huntsville, Alabama, for almost as long. During this period, proper test conditions for accurate and meaningful space simulation have been worked out, comparisons with actual space performance in spaceflight tests and with real operational satellites have been made, and NASA has achieved our own internal standards for test protocols. It is the purpose of this paper to communicate the test conditions, test procedures, and types of analysis used at NASA GRC and MSFC to the space environmental testing community at large, to help with international space-plasma arcing-testing standardization. Discussed herein are neutral gas conditions, plasma densities and uniformity, vacuum chamber sizes, sample sizes and Debye lengths, biasing samples versus self-generated voltages, floating samples versus grounded samples, test electrical conditions, arc detection, preventing sustained discharges during testing, real samples versus idealized samples, validity of LEO tests for GEO samples, extracting arc threshold information from arc rate versus voltage tests, snapover, current collection, and glows at positive sample bias, Kapton pyrolysis, thresholds for trigger arcs, sustained arcs, dielectric breakdown and Paschen discharge, tether arcing and testing in very dense plasmas (i.e. thruster plumes), arc mitigation strategies, charging mitigation strategies, models, and analysis of test results. Finally, the necessity of testing will be emphasized, not to the exclusion of modeling, but as part of a complete strategy for determining when and if arcs will occur, and preventing them from occurring in space.

  20. Comprehensive Analysis of Low-Molecular-Weight Human Plasma Proteome Using Top-Down Mass Spectrometry.

    PubMed

    Cheon, Dong Huey; Nam, Eun Ji; Park, Kyu Hyung; Woo, Se Joon; Lee, Hye Jin; Kim, Hee Cheol; Yang, Eun Gyeong; Lee, Cheolju; Lee, Ji Eun

    2016-01-04

    While human plasma serves as a great source for disease diagnosis, low-molecular-weight (LMW) proteome (<30 kDa) has been shown to contain a rich source of diagnostic biomarkers. Here we employ top-down mass spectrometry to analyze the LMW proteoforms present in four types of human plasma samples pooled from three healthy controls (HCs) without immunoaffinity depletion and with depletion of the top two, six, and seven high-abundance proteins. The LMW proteoforms were first fractionated based on molecular weight using gel-eluted liquid fraction entrapment electrophoresis (GELFrEE). Then, the GELFrEE fractions containing up to 30 kDa were subjected to nanocapillary-LC-MS/MS, and the high-resolution MS and MS/MS data were processed using ProSightPC 3.0. As a result, a total of 442 LMW proteins and cleaved products, including those with post-translational modifications and single amino acid variations, were identified. From additional comparative analysis of plasma samples without immunoaffinity depletion between HCs and colorectal cancer (CRC) patients via top-down approach, tens of LMW proteoforms, including platelet factor 4, were found to show >1.5-fold changes between the plasma samples of HCs and CRC patients, and six of the LMW proteins were verified by Western blot analysis.

  1. Concurrent profiling of polar metabolites and lipids in human plasma using HILIC-FTMS

    NASA Astrophysics Data System (ADS)

    Cai, Xiaoming; Li, Ruibin

    2016-11-01

    Blood plasma is the most popularly used sample matrix for metabolite profiling studies, which aim to achieve global metabolite profiling and biomarker discovery. However, most of the current studies on plasma metabolite profiling focused on either the polar metabolites or lipids. In this study, a comprehensive analysis approach based on HILIC-FTMS was developed to concurrently examine polar metabolites and lipids. The HILIC-FTMS method was developed using mixed standards of polar metabolites and lipids, the separation efficiency of which is better in HILIC mode than in C5 and C18 reversed phase (RP) chromatography. This method exhibits good reproducibility in retention times (CVs < 3.43%) and high mass accuracy (<3.5 ppm). In addition, we found MeOH/ACN/Acetone (1:1:1, v/v/v) as extraction cocktail could achieve desirable gathering of demanded extracts from plasma samples. We further integrated the MeOH/ACN/Acetone extraction with the HILIC-FTMS method for metabolite profiling and smoking-related biomarker discovery in human plasma samples. Heavy smokers could be successfully distinguished from non smokers by univariate and multivariate statistical analysis of the profiling data, and 62 biomarkers for cigarette smoke were found. These results indicate that our concurrent analysis approach could be potentially used for clinical biomarker discovery, metabolite-based diagnosis, etc.

  2. Screening for phaeochromocytoma and paraganglioma: impact of using supine reference intervals for plasma metanephrines with samples collected from fasted/seated patients.

    PubMed

    Casey, R; Griffin, T P; Wall, D; Dennedy, M C; Bell, M; O'Shea, P M

    2017-01-01

    Background The Endocrine Society Clinical Practice Guideline on Phaeochomocytoma and Paraganglioma recommends phlebotomy for plasma-free metanephrines with patients fasted and supine using appropriately defined reference intervals. Studies have shown higher diagnostic sensitivities using these criteria. Further, with seated-sampling protocols, for result interpretation, reference intervals that do not compromise diagnostic sensitivity should be employed. Objective To determine the impact on diagnostic performance and financial cost of using supine reference intervals for result interpretation with our current plasma-free metanephrines fasted/seated-sampling protocol. Methods We conducted a retrospective cohort study of patients who underwent screening for PPGL using plasma-free metanephrines from 2009 to 2014 at Galway University Hospitals. Plasma-free metanephrines were measured using liquid chromatography-tandem mass spectrometry. Supine thresholds for plasma normetanephrine and metanephrine set at 610 pmol/L and 310 pmol/L, respectively, were used. Results A total of 183 patients were evaluated. Mean age of participants was 53.4 (±16.3) years. Five of 183 (2.7%) patients had histologically confirmed PPGL (males, n=4). Using seated reference intervals for plasma-free metanephrines, diagnostic sensitivity and specificity were 100% and 98.9%, respectively, with two false-positive cases. Application of reference intervals established in subjects supine and fasted to this cohort gave diagnostic sensitivity of 100% with specificity of 74.7%. Financial analysis of each pretesting strategy demonstrated cost-equivalence (€147.27/patient). Conclusion Our cost analysis, together with the evidence that fasted/supine-sampling for plasma-free metanephrines, offers more reliable exclusion of PPGL mandates changing our current practice. This study highlights the important advantages of standardized diagnostic protocols for plasma-free metanephrines to ensure the highest diagnostic accuracy for investigation of PPGL.

  3. Random and independent sampling of endogenous tryptic peptides from normal human EDTA plasma by liquid chromatography micro electrospray ionization and tandem mass spectrometry.

    PubMed

    Dufresne, Jaimie; Florentinus-Mefailoski, Angelique; Ajambo, Juliet; Ferwa, Ammara; Bowden, Peter; Marshall, John

    2017-01-01

    Normal human EDTA plasma samples were collected on ice, processed ice cold, and stored in a freezer at - 80 °C prior to experiments. Plasma test samples from the - 80 °C freezer were thawed on ice or intentionally warmed to room temperature. Protein content was measured by CBBR binding and the release of alcohol soluble amines by the Cd ninhydrin assay. Plasma peptides released over time were collected over C18 for random and independent sampling by liquid chromatography micro electrospray ionization and tandem mass spectrometry (LC-ESI-MS/MS) and correlated with X!TANDEM. Fully tryptic peptides by X!TANDEM returned a similar set of proteins, but was more computationally efficient, than "no enzyme" correlations. Plasma samples maintained on ice, or ice with a cocktail of protease inhibitors, showed lower background amounts of plasma peptides compared to samples incubated at room temperature. Regression analysis indicated that warming plasma to room temperature, versus ice cold, resulted in a ~ twofold increase in the frequency of peptide identification over hours-days of incubation at room temperature. The type I error rate of the protein identification from the X!TANDEM algorithm combined was estimated to be low compared to a null model of computer generated random MS/MS spectra. The peptides of human plasma were identified and quantified with low error rates by random and independent sampling that revealed 1000s of peptides from hundreds of human plasma proteins from endogenous tryptic peptides.

  4. Creation of fluorocarbon barriers on surfaces of starch-based products through cold plasma treatment

    NASA Astrophysics Data System (ADS)

    Han, Yousoo

    Two kinds of starch foam trays (starch and aspen-starch foam trays) were produced using a lab model baking machine. Surfaces of the trays were treated with CF4 and SF6 plasma to create fluorine-rich layers on the surfaces, which might show strong water resistance. The plasma parameters, such like RF power, gas pressure and reaction time, were varied to evaluate the effects of each parameter on fluorination of surfaces. The atomic concentrations of fluorine, oxygen and carbon on samples' surfaces were earned from ESCA (electron spectroscopy for chemical analysis) and contact angles of sample surfaces were measured for hydrophobicity. For water resistance of plasma treated surfaces, liquid water uptake and water vapor uptake test were performed. Also, equilibrium moisture contents of unmodified and plasma treated samples were measured to evaluate biodegradability of plasma treated samples. Fluorine-rich barriers were created on sample surfaces treated with CF 4 and SF6 plasma. The fluorine atomic concentrations of treated sample surfaces were ranged from 34.4% to 64.4% (CF4 treatment) and 43.6% to 57.9% (SF6 treatment). It was found at both plasma gases that plasma parameters affected total fluorine concentration and carbon-peak shapes in ESCA surveys, which imply different distributions of mono- or multi-fluoro carbon's contents. In various reaction times, it was found that total fluorine contents were decreased after a critical point as the reaction time was prolonged, which may imply that a dominant mechanism has been changed from deposition or functionalization to etching. Oxygen atomic concentration was decreased at sample surfaces treated by both plasmas. In the case of SF6 plasma, it was proved that the removal of oxygen surely occurred because there was no addition of sulfur species. Plasma treated sample surfaces had high contact angles with distilled water up to 150° and the high values of angles have been kept constant up to for 15 minutes. Fluorine-rich barriers created by plasma showed lower water liquid and vapor permeability than untreated surfaces did. Plasma treated samples had similar moisture contents with untreated samples at all relative humidity tested. AFM and SEM images were taken for sample surfaces' morphology and topography.

  5. On-line miniaturized asymmetrical flow field-flow fractionation-electrospray ionization-tandem mass spectrometry with selected reaction monitoring for quantitative analysis of phospholipids in plasma lipoproteins.

    PubMed

    Yang, Iseul; Kim, Ki Hun; Lee, Ju Yong; Moon, Myeong Hee

    2014-01-10

    A direct analytical method for high speed quantitative analysis of lipids in human blood plasma using on-line chip-type asymmetrical flow field-flow fractionation-electrospray ionization-tandem mass spectrometry (cAF4-ESI-MS/MS) with selected reaction monitoring (SRM) is described in this study. Utilizing a miniaturized cAF4 channel, high speed size separation of high density lipoproteins (HDL) and low density lipoproteins (LDL) from plasma samples can be accomplished at a microflow rate along with simultaneous desalting of lipoproteins, both of which are conducive to direct ESI of lipids in lipoproteins. This study demonstrates that the SRM method to monitor phospholipids during cAF4-ESI-MS/MS can be successfully applied to the quantitation of lipid molecules in plasma lipoproteins without the need of a separate lipid extraction process. For quantitation of lipids in HDL and LDL during cAF4-ESI-MS/MS runs, a protein standard (carbonic anhydrase, 29 kDa) was added to each plasma sample as an internal standard such that a peak intensity of y67(+5) ions, which are high abundant SRM product ions of CA, could be utilized to calculate the relative intensity of each lipid molecule. The developed method was applied to plasma samples from 10 patients with coronary artery disease (CAD) and 10 healthy control samples, and quantitative analysis of 39 lipid molecules including phosphatidylcholines, phosphatidylethanolamines, sphingomyelins, phosphatidylglycerols, and phosphatidylinositols, resulted in the selection of 13 PL species showing more than 2.5 fold difference in relative abundance (p<0.01) between the groups. The present study demonstrates a high speed analytical method for determining plasma lipid content and distribution without an organic solvent extraction of lipids from plasma. Copyright © 2013 Elsevier B.V. All rights reserved.

  6. HPLC-MS/MS analysis of anthocyanins in human plasma and urine using protein precipitation and dilute-and-shoot sample preparation methods, respectively.

    PubMed

    Liu, Junguo; Song, Jiuxue; Huang, Karen; Michel, Deborah; Fang, Jim

    2018-05-01

    A high-performance liquid chromatography tandem-mass spectrometry (HPLC-MS/MS) method has been developed to analyze anthocyanins in urine and plasma to further understand their absorption, distribution, metabolism and excretion. The method employed a Synergi RP-Max column (250 × 4.6 mm, 4 μm) and an API 4000 mass spectrometer. A gradient elution system consisted of mobile phase A (water-1% formic acid) and mobile phase B (acetonitrile) with a flow rate of 0.60 mL/min. The gradient was initiated at 5% B, increased to 21% B at 20 min, and then increased to 40% B at 35 min. The analysis of anthocyanins presents a challenge because of the poor stability of anthocyanins during sample preparation, especially during solvent evaporation. In this method, the degradation of anthocyanins was minimized using protein precipitation and dilute-and-shoot and sample preparation methods for plasma and urine, respectively. No interferences were observed from endogenous compounds. The method has been used to analyze anthocyanin concentrations in urine and plasma samples from volunteers administered saskatoon berries. Cyanidin-3-galactoside, cyanidin-3-glucoside, cyanidin-3-arabinoside, cyanidin-3-xyloside and quercetin-3-galactoside, the five major flavonoid components in saskatoon berries, were identified in plasma and urine samples. Copyright © 2017 John Wiley & Sons, Ltd.

  7. Development of a Dual Plasma Desorption/Ionization System for the Noncontact and Highly Sensitive Analysis of Surface Adhesive Compounds

    PubMed Central

    Aida, Mari; Iwai, Takahiro; Okamoto, Yuki; Kohno, Satoshi; Kakegawa, Ken; Miyahara, Hidekazu; Seto, Yasuo; Okino, Akitoshi

    2017-01-01

    We developed a dual plasma desorption/ionization system using two plasmas for the semi-invasive analysis of compounds on heat-sensitive substrates such as skin. The first plasma was used for the desorption of the surface compounds, whereas the second was used for the ionization of the desorbed compounds. Using the two plasmas, each process can be optimized individually. A successful analysis of phenyl salicylate and 2-isopropylpyridine was achieved using the developed system. Furthermore, we showed that it was possible to detect the mass signals derived from a sample even at a distance 50 times greater than the distance from the position at which the samples were detached. In addition, to increase the intensity of the mass signal, 0%–0.02% (v/v) of hydrogen gas was added to the base gas generated in the ionizing plasma. We found that by optimizing the gas flow rate through the addition of a small amount of hydrogen gas, it was possible to obtain the intensity of the mass signal that was 45–824 times greater than that obtained without the addition of hydrogen gas. PMID:29234573

  8. [Search for potential gastric cancer biomarkers using low molecular weight blood plasma proteome profiling by mass spectrometry].

    PubMed

    Shevchenko, V E; Arnotskaia, N E; Ogorodnikova, E V; Davydov, M M; Ibraev, M A; Turkin, I N; Davydov, M I

    2014-01-01

    Gastric cancer, one of the most widespread malignant tumors, still lacks reliable serum/plasma biomarkers of its early detection. In this study we have developed, unified, and tested a new methodology for search of gastric cancer biomarkers based on profiling of low molecular weight proteome (LMWP) (1-17 kDa). This approach included three main components: sample pre-fractionation, matrix-assisted laser desorption ionization time of flight mass spectrometry (MALDI-TOF-MS), data analysis by a bioinformatics software package. Applicability and perspectives of the developed approach for detection of potential gastric cancer markers during LMWP analysis have been demonstrated using 69 plasma samples from patients with gastric cancer (stages I-IV) and 238 control samples. The study revealed peptides/polypeptides, which may be potentially used for detection of this pathology.

  9. MRM assay for quantitation of complement components in human blood plasma - a feasibility study on multiple sclerosis.

    PubMed

    Rezeli, Melinda; Végvári, Akos; Ottervald, Jan; Olsson, Tomas; Laurell, Thomas; Marko-Varga, György

    2011-12-10

    As a proof-of-principle study, a multiple reaction monitoring (MRM) assay was developed for quantitation of proteotypic peptides, representing seven plasma proteins associated with inflammation (complement components and C-reactive protein). The assay development and the sample analysis were performed on a linear ion trap mass spectrometer. We were able to quantify 5 of the 7 target proteins in depleted plasma digests with reasonable reproducibility over a 2 orders of magnitude linear range (RSD≤25%). The assay panel was utilized for the analysis of a small multiple sclerosis sample cohort with 10 diseased and 8 control patients. Copyright © 2011 Elsevier B.V. All rights reserved.

  10. Fluorination of vertically aligned carbon nanotubes: from CF4 plasma chemistry to surface functionalization.

    PubMed

    Struzzi, Claudia; Scardamaglia, Mattia; Colomer, Jean-François; Verdini, Alberto; Floreano, Luca; Snyders, Rony; Bittencourt, Carla

    2017-01-01

    The surface chemistry of plasma fluorinated vertically aligned carbon nanotubes (vCNT) is correlated to the CF 4 plasma chemical composition. The results obtained via FTIR and mass spectrometry are combined with the XPS and Raman analysis of the sample surface showing the dependence on different plasma parameters (power, time and distance from the plasma region) on the resulting fluorination. Photoemission and absorption spectroscopies are used to investigate the evolution of the electronic properties as a function of the fluorine content at the vCNT surface. The samples suffer a limited ageing effect, with a small loss of fluorine functionalities after two weeks in ambient conditions.

  11. Fluorination of vertically aligned carbon nanotubes: from CF4 plasma chemistry to surface functionalization

    PubMed Central

    Scardamaglia, Mattia; Colomer, Jean-François; Verdini, Alberto; Floreano, Luca; Snyders, Rony; Bittencourt, Carla

    2017-01-01

    The surface chemistry of plasma fluorinated vertically aligned carbon nanotubes (vCNT) is correlated to the CF4 plasma chemical composition. The results obtained via FTIR and mass spectrometry are combined with the XPS and Raman analysis of the sample surface showing the dependence on different plasma parameters (power, time and distance from the plasma region) on the resulting fluorination. Photoemission and absorption spectroscopies are used to investigate the evolution of the electronic properties as a function of the fluorine content at the vCNT surface. The samples suffer a limited ageing effect, with a small loss of fluorine functionalities after two weeks in ambient conditions. PMID:28904833

  12. Multi-elemental analysis of aqueous geochemical samples by quadrupole inductively coupled plasma-mass spectrometry (ICP-MS)

    USGS Publications Warehouse

    Wolf, Ruth E.; Adams, Monique

    2015-01-01

    Typically, quadrupole inductively coupled plasma-mass spectrometry (ICP-MS) is used to determine as many as 57 major, minor, and trace elements in aqueous geochemical samples, including natural surface water and groundwater, acid mine drainage water, and extracts or leachates from geological samples. The sample solution is aspirated into the inductively coupled plasma (ICP) which is an electrodeless discharge of ionized argon gas at a temperature of approximately 6,000 degrees Celsius. The elements in the sample solution are subsequently volatilized, atomized, and ionized by the ICP. The ions generated are then focused and introduced into a quadrupole mass filter which only allows one mass to reach the detector at a given moment in time. As the settings of the mass analyzer change, subsequent masses are allowed to impact the detector. Although the typical quadrupole ICP-MS system is a sequential scanning instrument (determining each mass separately), the scan speed of modern instruments is on the order of several thousand masses per second. Consequently, typical total sample analysis times of 2–3 minutes are readily achievable for up to 57 elements.

  13. Simple, fast and reliable liquid chromatographic and spectrophotometric methods for the determination of theophylline in urine, saliva and plasma samples.

    PubMed

    Charehsaz, Mohammad; Gürbay, Aylin; Aydin, Ahmet; Sahin, Gönül

    2014-01-01

    In this study, a high-performance liquid chromatographic method (HPLC) and UV spectrophotometric method were developed, validated and applied for the determination of theophylline in biological fluids. Liquid- liquid extraction is performed for isolation of the drug and elimination of plasma and saliva interferences. Urine samples were applied without any extraction. The chromatographic separation was achieved on a C18 column by using 60:40 methanol:water as mobile phase under isocratic conditions at a flow rate of 0.75 mL/min with UV detection at 280 nm in HPLC method. UV spectrophotometric analysis was performed at 275 nm. the limit of quantification: 1.1 µg/mL for urine, 1.9 µg/mL for saliva, 3.1 µg/mL for plasma; recovery: 94.85% for plasma, 100.45% for saliva, 101.39% for urine; intra-day precision: 0.22-2.33%, inter-day precision: 3.17-13.12%. Spectrophotometric analysis results were as follows: the limit of quantitation: 5.23 µg/mL for plasma, 8.7 µg/mL for urine; recovery: 98.27% for plasma, 95.25% for urine; intra-day precision: 2.37 - 3.00%, inter-day precision: 5.43-7.91%. It can be concluded that this validated HPLC method is easy, precise, accurate, sensitive and selective for determination of theophylline in biological samples. Also spectrophotometric analysis can be used where it can be applicable.

  14. Spectrochemical analysis of powdered biological samples using transversely excited atmospheric carbon dioxide laser plasma excitation

    NASA Astrophysics Data System (ADS)

    Zivkovic, Sanja; Momcilovic, Milos; Staicu, Angela; Mutic, Jelena; Trtica, Milan; Savovic, Jelena

    2017-02-01

    The aim of this study was to develop a simple laser induced breakdown spectroscopy (LIBS) method for quantitative elemental analysis of powdered biological materials based on laboratory prepared calibration samples. The analysis was done using ungated single pulse LIBS in ambient air at atmospheric pressure. Transversely-Excited Atmospheric pressure (TEA) CO2 laser was used as an energy source for plasma generation on samples. The material used for the analysis was a blue-green alga Spirulina, widely used in food and pharmaceutical industries and also in a few biotechnological applications. To demonstrate the analytical potential of this particular LIBS system the obtained spectra were compared to the spectra obtained using a commercial LIBS system based on pulsed Nd:YAG laser. A single sample of known concentration was used to estimate detection limits for Ba, Ca, Fe, Mg, Mn, Si and Sr and compare detection power of these two LIBS systems. TEA CO2 laser based LIBS was also applied for quantitative analysis of the elements in powder Spirulina samples. Analytical curves for Ba, Fe, Mg, Mn and Sr were constructed using laboratory produced matrix-matched calibration samples. Inductively coupled plasma optical emission spectroscopy (ICP-OES) was used as the reference technique for elemental quantification, and reasonably well agreement between ICP and LIBS data was obtained. Results confirm that, in respect to its sensitivity and precision, TEA CO2 laser based LIBS can be successfully applied for quantitative analysis of macro and micro-elements in algal samples. The fact that nearly all classes of materials can be prepared as powders implies that the proposed method could be easily extended to a quantitative analysis of different kinds of materials, organic, biological or inorganic.

  15. Analysis of non-esterified fatty acids in human samples by solid-phase-extraction and gas chromatography/mass spectrometry.

    PubMed

    Kopf, Thomas; Schmitz, Gerd

    2013-11-01

    The determination of the fatty acid (FA) profile of lipid classes is essential for lipidomic analysis. We recently developed a GC/MS-method for the analysis of the FA profile of total FAs, i.e. the totality of bound and unbound FAs, in any given biological sample (TOFAs). Here, we present a method for the analysis of non-esterified fatty acids (NEFAs) in biological samples, i.e. the fraction that is present as extractable free fatty acids. Lipid extraction is performed according to Dole using 80/20 2-propanol/n-hexane (v/v), with 0.1% H2SO4. The fatty acid-species composition of this NEFA-fraction is determined as FAME after derivatization with our GC/MS-method on a BPX column (Shimadzu). Validation of the NEFA-method presented was performed in human plasma samples. The validated method has been used with human plasma, cells and tissues, as well as mammalian body fluids and tissue samples. The newly developed solid-phase-extraction (SPE)-GC-MS method allows the rapid separation of the NEFA-fraction from a neutral lipid extract of plasma samples. As a major advantage compared to G-FID-methods, GC-MS allows the use of stable isotope labeled fatty acid precursors to monitor fatty acid metabolism. Copyright © 2013 Elsevier B.V. All rights reserved.

  16. Opioid Concentrations in Oral Fluid and Plasma in Cancer Patients With Pain.

    PubMed

    Heiskanen, Tarja; Langel, Kaarina; Gunnar, Teemu; Lillsunde, Pirjo; Kalso, Eija A

    2015-10-01

    Measuring opioid concentrations in pain treatment is warranted in situations where optimal opioid analgesia is difficult to reach. To assess the usefulness of oral fluid (OFL) as an alternative to plasma in opioid concentration monitoring in cancer patients on chronic opioid therapy. We collected OFL and plasma samples from 64 cancer patients on controlled-release (CR) oral morphine, CR oral oxycodone, or transdermal (TD) fentanyl for pain. Samples were obtained on up to five separate days. A total of 213 OFL and plasma samples were evaluable. All patients had detectable amounts of the CR or TD opioid in both plasma and OFL samples. The plasma concentrations of oxycodone and fentanyl (determination coefficient R(2) = 0.628 and 0.700, respectively), but not morphine (R(2) = 0.292), were moderately well correlated to the daily opioid doses. In contrast to morphine and fentanyl (mean OFL/plasma ratio 2.0 and 3.0, respectively), the OFL oxycodone concentrations were significantly higher than the respective plasma concentrations (mean OFL/plasma ratio 14.9). An active transporter could explain the much higher OFL vs. plasma concentrations of oxycodone compared with morphine and fentanyl. OFL analysis is well suited for detecting the studied opioids. For morphine and fentanyl, an approximation of the plasma opioid concentrations is obtainable, whereas for oxycodone, the OFL/plasma concentration relationship is too variable for reliable approximation results. Copyright © 2015 American Academy of Hospice and Palliative Medicine. Published by Elsevier Inc. All rights reserved.

  17. Differences in metabolite profiles caused by pre-analytical blood processing procedures.

    PubMed

    Nishiumi, Shin; Suzuki, Makoto; Kobayashi, Takashi; Yoshida, Masaru

    2018-05-01

    Recently, the use of metabolomic analysis of human serum and plasma for biomarker discovery and disease diagnosis in clinical studies has been increasing. The feasibility of using a metabolite biomarker for disease diagnosis is strongly dependent on the metabolite's stability during pre-analytical blood processing procedures, such as serum or plasma sampling and sample storage prior to centrifugation. However, the influence of blood processing procedures on the stability of metabolites has not been fully characterized. In the present study, we compared the levels of metabolites in matched human serum and plasma samples using gas chromatography coupled with mass spectrometry and liquid chromatography coupled with mass spectrometry. In addition, we evaluated the changes in plasma metabolite levels induced by storage at room temperature or at a cold temperature prior to centrifugation. As a result, it was found that 76 metabolites exhibited significant differences between their serum and plasma levels. Furthermore, the pre-centrifugation storage conditions significantly affected the plasma levels of 45 metabolites. These results highlight the importance of blood processing procedures during metabolome analysis, which should be considered during biomarker discovery and the subsequent use of biomarkers for disease diagnosis. Copyright © 2017 The Society for Biotechnology, Japan. Published by Elsevier B.V. All rights reserved.

  18. Microwave plasma monitoring system for the elemental composition analysis of high temperature process streams

    DOEpatents

    Woskov, Paul P.; Cohn, Daniel R.; Titus, Charles H.; Surma, Jeffrey E.

    1997-01-01

    Microwave-induced plasma for continuous, real time trace element monitoring under harsh and variable conditions. The sensor includes a source of high power microwave energy and a shorted waveguide made of a microwave conductive, high temperature capability refractory material communicating with the source of the microwave energy to generate a plasma. The high power waveguide is constructed to be robust in a hot, hostile environment. It includes an aperture for the passage of gases to be analyzed and a spectrometer is connected to receive light from the plasma. Provision is made for real time in situ calibration. The spectrometer disperses the light, which is then analyzed by a computer. The sensor is capable of making continuous, real time quantitative measurements of desired elements, such as the heavy metals lead and mercury. The invention may be incorporated into a high temperature process device and implemented in situ for example, such as with a DC graphite electrode plasma arc furnace. The invention further provides a system for the elemental analysis of process streams by removing particulate and/or droplet samples therefrom and entraining such samples in the gas flow which passes through the plasma flame. Introduction of and entraining samples in the gas flow may be facilitated by a suction pump, regulating gas flow, gravity or combinations thereof.

  19. [Qualitative and quantitative analysis of amygdalin and its metabolite prunasin in plasma by ultra-high performance liquid chromatography-tandem quadrupole time of flight mass spectrometry and ultra-high performance liquid chromatography-tandem triple quadrupole mass spectrometry].

    PubMed

    Gao, Meng; Wang, Yuesheng; Wei, Huizhen; Ouyang, Hui; He, Mingzhen; Zeng, Lianqing; Shen, Fengyun; Guo, Qiang; Rao, Yi

    2014-06-01

    A method was developed for the determination of amygdalin and its metabolite prunasin in rat plasma after intragastric administration of Maxing shigan decoction. The analytes were identified by ultra-high performance liquid chromatography-tandem quadrupole time of flight mass spectrometry and quantitatively determined by ultra-high performance liquid chromatography-tandem triple quadrupole mass spectrometry. After purified by liquid-liquid extraction, the qualitative analysis of amygdalin and prunasin in the plasma sample was performed on a Shim-pack XR-ODS III HPLC column (75 mm x 2.0 mm, 1.6 microm), using acetonitrile-0.1% (v/v) formic acid aqueous solution. The detection was performed on a Triple TOF 5600 quadrupole time of flight mass spectrometer. The quantitative analysis of amygdalin and prunasin in the plasma sample was performed by separation on an Agilent C18 HPLC column (50 mm x 2.1 mm, 1.7 microm), using acetonitrile-0.1% (v/v) formic acid aqueous solution. The detection was performed on an AB Q-TRAP 4500 triple quadrupole mass spectrometer utilizing electrospray ionization (ESI) interface operated in negative ion mode and multiple-reaction monitoring (MRM) mode. The qualitative analysis results showed that amygdalin and its metabolite prunasin were detected in the plasma sample. The quantitative analysis results showed that the linear range of amygdalin was 1.05-4 200 ng/mL with the correlation coefficient of 0.999 0 and the linear range of prunasin was 1.25-2 490 ng/mL with the correlation coefficient of 0.997 0. The method had a good precision with the relative standard deviations (RSDs) lower than 9.20% and the overall recoveries varied from 82.33% to 95.25%. The limits of detection (LODs) of amygdalin and prunasin were 0.50 ng/mL. With good reproducibility, the method is simple, fast and effective for the qualitative and quantitative analysis of the amygdalin and prunasin in plasma sample of rats which were administered by Maxing shigan decoction.

  20. Multielemental analysis of prehistoric animal teeth by laser-induced breakdown spectroscopy and laser ablation inductively coupled plasma mass spectrometry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Galiova, Michaela; Kaiser, Jozef; Fortes, Francisco J.

    2010-05-01

    Laser-induced breakdown spectroscopy (LIBS) and laser ablation (LA) inductively coupled plasma (ICP) mass spectrometry (MS) were utilized for microspatial analyses of a prehistoric bear (Ursus arctos) tooth dentine. The distribution of selected trace elements (Sr, Ba, Fe) was measured on a 26 mmx15 mm large and 3 mm thick transverse cross section of a canine tooth. The Na and Mg content together with the distribution of matrix elements (Ca, P) was also monitored within this area. The depth of the LIBS craters was measured with an optical profilometer. As shown, both LIBS and LA-ICP-MS can be successfully used for themore » fast, spatially resolved analysis of prehistoric teeth samples. In addition to microchemical analysis, the sample hardness was calculated using LIBS plasma ionic-to-atomic line intensity ratios of Mg (or Ca). To validate the sample hardness calculations, the hardness was also measured with a Vickers microhardness tester.« less

  1. Solvent-modified solid-phase microextraction for the determination of diazepam in human plasma samples by capillary gas chromatography.

    PubMed

    Krogh, M; Grefslie, H; Rasmussen, K E

    1997-02-21

    This paper describes microextraction and gas chromatographic analysis of diazepam from human plasma. The method was based on immobilisation of 1.5 microliters of 1-octanol on a polyacrylate-coated fiber designed for solid-phase microextraction. The solvent-modified fibre was used to extract diazepam from the samples. The plasma sample was pre-treated to release diazepam from the protein binding. The fibre was inserted into the modified plasma sample, adjusted to pH 5.5 an internal standard was added and the mixture was carefully stirred for 4 min. The fibre with the immobilised solvent and the enriched analytes was injected into the capillary gas chromatograph. The solvent and the extracted analytes were evaporated at 300 degrees C in the split-splitless injection port of the gas chromatograph, separated on a methylsilicon capillary column and detected with a nitrogen-phosphorus detector. The method was shown to be reproducible with a detection limit of 0.10 nmol/ml in human plasma.

  2. Comparison of cross-sectional HIV incidence assay results from dried blood spots and plasma.

    PubMed

    Schlusser, Katherine E; Pilcher, Christopher; Kallas, Esper G; Santos, Breno R; Deeks, Steven G; Facente, Shelley; Keating, Sheila M; Busch, Michael P; Murphy, Gary; Welte, Alex; Quinn, Thomas; Eshleman, Susan H; Laeyendecker, Oliver

    2017-01-01

    Assays have been developed for cross-sectional HIV incidence estimation using plasma samples. Large scale surveillance programs are planned using dried blood spot (DBS) specimens for incidence assessment. However, limited information exists on the performance of HIV cross-sectional incidence assays using DBS. The assays evaluated were: Maxim HIV-1 Limiting Antigen Avidity EIA (LAg-Avidity), Sedia HIV-1 BED-Capture EIA (BED-CEIA), and CDC modified BioRad HIV-1/2 Plus O Avidity-based Assay (CDC-BioRad Avidity) using pre-determined cutoff values. 100 matched HIV-1 positive plasma and DBS samples, with known duration of infection, from the Consortium for the Evaluation and Performance of HIV Incidence Assays repository were tested. All assays were run in duplicate. To examine the degree of variability within and between results for each sample type, both categorical and continuous results were analyzed. Associations were assessed with Bland Altman, R2 values and Cohen's kappa coefficient (ĸ). Intra-assay variability using the same sample type was similar for all assays (R2 0.96 to 1.00). The R2 values comparing DBS and plasma results for LAg-Avidity, BED-CEIA, and CDC-BioRad Avidity were 0.96, 0.94, and 0.84, respectively. The concordance and ĸ values between DBS and plasma for all three assays were >87% and >0.64, respectively. The Bland-Altman analysis showed significant differences between plasma and DBS samples. For all three assays, a higher number of samples were classified as recent infections using DBS samples. DBS and plasma sample results were highly correlated. However, when compared to plasma, each assay performed somewhat differently in DBS at the lower and higher ends of the dynamic range. DBS samples were more likely to be classified as recently infected by all three assays, which may lead to overestimation of incidence in surveys using performance criteria derived for plasma samples.

  3. Unbiased Scanning Method and Data Banking Approach Using Ultra-High Performance Liquid Chromatography Coupled with High-Resolution Mass Spectrometry for Quantitative Comparison of Metabolite Exposure in Plasma across Species Analyzed at Different Dates.

    PubMed

    Gao, Hongying; Deng, Shibing; Obach, R Scott

    2015-12-01

    An unbiased scanning methodology using ultra high-performance liquid chromatography coupled with high-resolution mass spectrometry was used to bank data and plasma samples for comparing the data generated at different dates. This method was applied to bank the data generated earlier in animal samples and then to compare the exposure to metabolites in animal versus human for safety assessment. With neither authentic standards nor prior knowledge of the identities and structures of metabolites, full scans for precursor ions and all ion fragments (AIF) were employed with a generic gradient LC method to analyze plasma samples at positive and negative polarity, respectively. In a total of 22 tested drugs and metabolites, 21 analytes were detected using this unbiased scanning method except that naproxen was not detected due to low sensitivity at negative polarity and interference at positive polarity; and 4'- or 5-hydroxy diclofenac was not separated by a generic UPLC method. Statistical analysis of the peak area ratios of the analytes versus the internal standard in five repetitive analyses over approximately 1 year demonstrated that the analysis variation was significantly different from sample instability. The confidence limits for comparing the exposure using peak area ratio of metabolites in animal plasma versus human plasma measured over approximately 1 year apart were comparable to the analysis undertaken side by side on the same days. These statistical analysis results showed it was feasible to compare data generated at different dates with neither authentic standards nor prior knowledge of the analytes.

  4. [The possibility of using PlasmaDeepDive™ MRM panel in clinical diagnostics].

    PubMed

    Miroshnichenko, Iu V; Petushkova, N A; Moskaleva, N E; Teryaeva, N B; Zgoda, V G; Ilgisonis, E V; Belyaev, A Yu

    2015-01-01

    Concentrations of 46 proteins have been determined in human blood plasma using PlasmaDeepDive™ MRM Panel ("Biognosys AG", Switzerland). 18 of them were included into the group of proteins with higher concentrations, also identified by the shotgun proteomic analysis. Based on literature data it is concluded that the PlasmaDeepDive™ MRM Panel is applicable for studies of human plasma samples for potential biomarkers of various nervous system disorders.

  5. A membrane-separator interface for mass-spectrometric analysis of blood plasma

    NASA Astrophysics Data System (ADS)

    Elizarov, A. Yu.; Gerasimov, D. G.

    2014-09-01

    We demonstrate the possibility of rapid mass-spectrometric determination of the content of anesthetic agents in blood plasma with the aid of a membrane-separator interface. The interface employs a hydrophobic selective membrane that is capable of separating various anesthetic drugs (including inhalation anesthetic sevofluran, noninhalation anesthetic thiopental, hypnotic propofol, and opioid analgesic fentanyl) from the blood plasma and introducing samples into a mass spectrometer. Analysis of the blood plasma was not accompanied by the memory effect and did not lead to membrane degradation. Results of clinical investigation of the concentration of anesthetics in the blood plasma of patients are presented.

  6. Reproducibility of Digital PCR Assays for Circulating Tumor DNA Analysis in Advanced Breast Cancer

    PubMed Central

    Hrebien, Sarah; O’Leary, Ben; Beaney, Matthew; Schiavon, Gaia; Fribbens, Charlotte; Bhambra, Amarjit; Johnson, Richard; Turner, Nicholas

    2016-01-01

    Circulating tumor DNA (ctDNA) analysis has the potential to allow non-invasive analysis of tumor mutations in advanced cancer. In this study we assessed the reproducibility of digital PCR (dPCR) assays of circulating tumor DNA in a cohort of patients with advanced breast cancer and assessed delayed plasma processing using cell free DNA preservative tubes. We recruited a cohort of 96 paired samples from 71 women with advanced breast cancer who had paired blood samples processed either immediately or delayed in preservative tubes with processing 48–72 hours after collection. Plasma DNA was analysed with multiplex digital PCR (mdPCR) assays for hotspot mutations in PIK3CA, ESR1 and ERBB2, and for AKT1 E17K. There was 94.8% (91/96) agreement in mutation calling between immediate and delayed processed tubes, kappa 0.88 95% CI 0.77–0.98). Discordance in mutation calling resulted from low allele frequency and likely stochastic effects. In concordant samples there was high correlation in mutant copies per ml plasma (r2 = 0.98; p<0.0001). There was elevation of total cell free plasma DNA concentrations in 10.3% of delayed processed tubes, although overall quantification of total cell free plasma DNA had similar prognostic effects in immediate (HR 3.6) and delayed (HR 3.0) tubes. There was moderate agreement in changes in allele fraction between sequential samples in quantitative mutation tracking (r = 0.84, p = 0.0002). Delayed processing of samples using preservative tubes allows for centralized ctDNA digital PCR mutation screening in advanced breast cancer. The potential of preservative tubes in quantitative mutation tracking requires further research. PMID:27760227

  7. Reproducibility of Digital PCR Assays for Circulating Tumor DNA Analysis in Advanced Breast Cancer.

    PubMed

    Hrebien, Sarah; O'Leary, Ben; Beaney, Matthew; Schiavon, Gaia; Fribbens, Charlotte; Bhambra, Amarjit; Johnson, Richard; Garcia-Murillas, Isaac; Turner, Nicholas

    2016-01-01

    Circulating tumor DNA (ctDNA) analysis has the potential to allow non-invasive analysis of tumor mutations in advanced cancer. In this study we assessed the reproducibility of digital PCR (dPCR) assays of circulating tumor DNA in a cohort of patients with advanced breast cancer and assessed delayed plasma processing using cell free DNA preservative tubes. We recruited a cohort of 96 paired samples from 71 women with advanced breast cancer who had paired blood samples processed either immediately or delayed in preservative tubes with processing 48-72 hours after collection. Plasma DNA was analysed with multiplex digital PCR (mdPCR) assays for hotspot mutations in PIK3CA, ESR1 and ERBB2, and for AKT1 E17K. There was 94.8% (91/96) agreement in mutation calling between immediate and delayed processed tubes, kappa 0.88 95% CI 0.77-0.98). Discordance in mutation calling resulted from low allele frequency and likely stochastic effects. In concordant samples there was high correlation in mutant copies per ml plasma (r2 = 0.98; p<0.0001). There was elevation of total cell free plasma DNA concentrations in 10.3% of delayed processed tubes, although overall quantification of total cell free plasma DNA had similar prognostic effects in immediate (HR 3.6) and delayed (HR 3.0) tubes. There was moderate agreement in changes in allele fraction between sequential samples in quantitative mutation tracking (r = 0.84, p = 0.0002). Delayed processing of samples using preservative tubes allows for centralized ctDNA digital PCR mutation screening in advanced breast cancer. The potential of preservative tubes in quantitative mutation tracking requires further research.

  8. Adhesive blood microsampling systems for steroid measurement via LC-MS/MS in the rat.

    PubMed

    Heussner, Kirsten; Rauh, Manfred; Cordasic, Nada; Menendez-Castro, Carlos; Huebner, Hanna; Ruebner, Matthias; Schmidt, Marius; Hartner, Andrea; Rascher, Wolfgang; Fahlbusch, Fabian B

    2017-04-01

    Liquid Chromatography Tandem Mass Spectrometry (LC-MS/MS) allows for the direct analysis of multiple hormones in a single probe with minimal sample volume. Rodent-based animal studies strongly rely on microsampling, such as the dry blood spot (DBS) method. However, DBS suffers the drawback of hematocrit-dependence (non-volumetric). Hence, novel volumetric microsampling techniques were introduced recently, allowing sampling of fixed accurate volumes. We compared these methods for steroid analysis in the rat to improve inter-system comparability. We analyzed steroid levels in blood using the absorptive microsampling devices Whatman® 903 Protein Saver Cards, Noviplex™ Plasma Prep Cards and the Mitra™ Microsampling device and compared the obtained results to the respective EDTA plasma levels. Quantitative steroid analysis was performed via LC-MS/MS. For the determination of the plasma volume factor for each steroid, their levels in pooled blood samples from each human adults and rats (18weeks) were compared and the transferability of these factors was evaluated in a new set of juvenile (21days) and adult (18weeks) rats. Hematocrit was determined concomitantly. Using these approaches, we were unable to apply one single volume factor for each steroid. Instead, plasma volume factors had to be adjusted for the recovery rate of each steroid and device individually. The tested microsampling systems did not allow the use of one single volume factor for adult and juvenile rats based on an unexpectedly strong hematocrit-dependency and other steroid specific (pre-analytic) factors. Our study provides correction factors for LC-MS/MS steroid analysis of volumetric and non-volumetric microsampling systems in comparison to plasma. It argues for thorough analysis of chromatographic effects before the use of novel volumetric systems for steroid analysis. Copyright © 2017 Elsevier Inc. All rights reserved.

  9. A new restricted access molecularly imprinted polymer capped with albumin for direct extraction of drugs from biological matrices: the case of chlorpromazine in human plasma.

    PubMed

    de Oliveira Isac Moraes, Gabriel; da Silva, Larissa Meirelles Rodrigues; dos Santos-Neto, Alvaro José; Florenzano, Fábio Herbst; Figueiredo, Eduardo Costa

    2013-09-01

    A new restricted access molecularly imprinted polymer coated with bovine serum albumin (RAMIP-BSA) was developed, characterized, and used for direct analysis of chlorpromazine in human plasma samples. The RAMIP-BSA was synthesized using chlorpromazine, methacrylic acid, and ethylene glycol dimethacrylate as template, functional monomer, and cross-linker, respectively. Glycerol dimethacrylate and hydroxy methyl methacrylate were used to promote a hydrophilic surface (high density of hydroxyl groups). Afterward, the polymer was coated with BSA using glutaraldehyde as cross-linker, resulting in a protein chemical shield around it. The material was able to eliminate ca. 99% of protein when a 44-mg mL(-1) BSA aqueous solution was passed through it. The RAMIP-BSA was packed in a column and used for direct analysis of chlorpromazine in human plasma samples in an online column switching high-performance liquid chromatography system. The analytical calibration curve was prepared in a pool of human plasma samples with chlorpromazine concentrations ranging from 30 to 350 μg L(-1). The correlation coefficient obtained was 0.995 and the limit of quantification was 30 μg L(-1). Intra-day and inter-day precision and accuracy presented variation coefficients and relative errors lower than 15% and within -15 and 15%, respectively. The sample throughput was 3 h(-1) (sample preparation and chromatographic analysis steps) and the same RAMIP-BSA column was efficiently used for about 90 cycles.

  10. Molecularly imprinted polymer cartridges coupled on-line with high performance liquid chromatography for simple and rapid analysis of dextromethorphan in human plasma samples.

    PubMed

    Moein, Mohammad Mahdi; Javanbakht, Mehran; Akbari-Adergani, Behrouz

    2011-04-01

    In this paper, a novel method is described for automated determination of dextromethorphan in biological fluids using molecularly imprinted solid-phase extraction (MISPE) as a sample clean-up technique combined with high performance liquid chromatography (HPLC). The water-compatible molecularly imprinted polymers (MIPs) were prepared using methacrylic acid as functional monomer, ethylene glycol dimethacrylate as cross-linker, chloroform as porogen and dextromethorphan as template molecule. These imprinted polymers were used as solid-phase extraction sorbent for the extraction of dextromethorphan from human plasma samples. Various parameters affecting the extraction efficiency of the MIP cartridges were evaluated. The high selectivity of the sorbent coupled to the high performance liquid chromatographic system permitted a simple and rapid analysis of this drug in plasma samples with limits of detection (LOD) and quantification (LOQ) of 0.12 ng/mL and 0.35 ng/mL, respectively. The MIP selectivity was evaluated by analyzing of the dextromethorphan in presence of several substances with similar molecular structures and properties. Results from the HPLC analyses showed that the recoveries of dextromethorphan using MIP cartridges from human plasma samples in the range of 1-50 ng/mL were higher than 87%. Copyright © 2011 Elsevier B.V. All rights reserved.

  11. Plasma synthesis, Mössbauer spectroscopy and X-ray diffraction studies of nanosized iron oxides

    NASA Astrophysics Data System (ADS)

    Paneva, Daniela; Zaharieva, Katerina; Grabis, Janis; Mitov, Ivan; Vissokov, Gheorghi

    2010-06-01

    In this article synthesis and study of iron oxide nanopowders are described. The synthesis of sample 1 and sample 2—iron oxides—was carried out by electric arc plasma cutting of ordinary steel. The sample 3 was prepared by evaporation of Fe2O3/FeO mixture in radio-frequency nitrogen plasma. The characterization of the as prepared iron oxide nanoproducts was achieved by means of Mössbauer spectroscopy and X-ray diffraction analysis. The presence of different phases of iron oxide with a basic phase Fe3 - xO4 (magnetite), additional Fe1 - xO (wüstite) and α or γ-Fe2O3 (hematite or maghemite) with superparamagnetic particles for sample 1 and sample 2 and Fe3 - xO4 (magnetite) for sample 3 is observed.

  12. Simultaneous determination of dextromethorphan, dextrorphan, and guaifenesin in human plasma using semi-automated liquid/liquid extraction and gradient liquid chromatography tandem mass spectrometry.

    PubMed

    Eichhold, Thomas H; McCauley-Myers, David L; Khambe, Deepa A; Thompson, Gary A; Hoke, Steven H

    2007-01-17

    A method for the simultaneous determination of dextromethorphan (DEX), dextrorphan (DET), and guaifenesin (GG) in human plasma was developed, validated, and applied to determine plasma concentrations of these compounds in samples from six clinical pharmacokinetic (PK) studies. Semi-automated liquid handling systems were used to perform the majority of the sample manipulation including liquid/liquid extraction (LLE) of the analytes from human plasma. Stable-isotope-labeled analogues were utilized as internal standards (ISTDs) for each analyte to facilitate accurate and precise quantification. Extracts were analyzed using gradient liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS). Use of semi-automated LLE with LC-MS/MS proved to be a very rugged and reliable approach for analysis of more than 6200 clinical study samples. The lower limit of quantification was validated at 0.010, 0.010, and 1.0 ng/mL of plasma for DEX, DET, and GG, respectively. Accuracy and precision of quality control (QC) samples for all three analytes met FDA Guidance criteria of +/-15% for average QC accuracy with coefficients of variation less than 15%. Data from the thorough evaluation of the method during development, validation, and application are presented to characterize selectivity, linearity, over-range sample analysis, accuracy, precision, autosampler carry-over, ruggedness, extraction efficiency, ionization suppression, and stability. Pharmacokinetic data are also provided to illustrate improvements in systemic drug and metabolite concentration-time profiles that were achieved by formulation optimization.

  13. Comparison of EML 105 and advantage analysers measuring capillary versus venous whole blood glucose in neonates.

    PubMed

    McNamara, P J; Sharief, N

    2001-09-01

    Near-patient blood glucose monitoring is an essential component of neonatal intensive care but the analysers currently used are unreliable and inaccurate. The aim of this study was to compare a new glucose electrode-based analyser (EML 105) and a non-wipe reflectance photometry method (Advantage) as opposed to a recognized laboratory reference method (Hexokinase). We also investigated the effect of sample route and haematocrit on the accuracy of the glucose readings obtained by each method of analysis. Whole blood glucose concentrations ranging from 0 to 3.5 mmol/l were carefully prepared in a laboratory setting and blood samples from each respective solution were then measured by EML 105 and Advantage analysers. The results obtained were then compared with the corresponding plasma glucose reading obtained by the Hexokinase method, using linear regression analysis. An in vivo study was subsequently performed on 103 neonates, over a 1-y period, using capillary and venous whole blood samples. Whole blood glucose concentration was estimated from each sample using both analysers and compared with the corresponding plasma glucose concentration estimated by the Hexokinase method. Venous blood was centrifuged and haematocrit was estimated using standardized curves. The effect of haematocrit on the agreement between whole blood and plasma glucose was investigated, estimating the degree of correlation on a scatterplot of the results and linear regression analysis. Both the EML 105 and Hexokinase methods were highly accurate, in vitro, with small proportional biases of 2% and 5%, respectively. However, in vivo, both study analysers overestimated neonatal plasma glucose, ranging from at best 0.45 mmol/l (EML 105 venous) to 0.69 mmol/l (EML capillary). There was no significant difference in the agreement of capillary (GD = 0.12, 95% CI, [-0.32,0.08], p = 0.2) or venous samples (GD = 0.05, 95% CI. [0.09, 0.19], p = 0.49) with plasma glucose when analysed by either study method (GD = glucose difference between study analyser and reference method) However, the venous samples analysed by EML 105 estimated plasma glucose significantly better than capillary samples using the same method of analysis (GD = 0.24, 95% CI. [0.09,0.38], p < 0.01). The relationship between haematocrit and the resultant glucose differences was non-linear with correlation coefficients of r = -0.057 (EML 105 capillary), r = 0.145 (EML 105 venous), r = -0.127 (Advantage capillary) and r = -0.275 (Advantage venous). There was no significant difference in the effect of haematocrit on the performance of EML 105 versus Advantage, regardless of the sample route. Both EML 105 and Advantage overestimated plasma glucose, with no significant difference in the performance of either analyser, regardless of the route of analysis. Agreement with plasma glucose was better for venous samples but this was only statistically significant when EML 105 capillary and venous results were compared. Haematocrit is not a significant confounding factor towards the performance of either EML 105 or Advantage in neonates, regardless of the route of sampling. The margin of overestimation of blood glucose prohibits the recommendation of both EML 105 and Advantage for routine neonatal glucose screening. The consequences include failure accurately to diagnose hypoglycaemia and delays in the instigation of therapeutic measures, both of which may potentially result in an adverse, long-term, neurodevelopmental outcome.

  14. A validated UPLC-MS/MS method for the analysis of linezolid and a novel oxazolidinone derivative (PH027) in plasma and its application to tissue distribution study in rabbits.

    PubMed

    Hedaya, Mohsen A; Thomas, Vidhya; Abdel-Hamid, Mohamed E; Kehinde, Elijah O; Phillips, Oludotun A

    2017-01-01

    Linezolid is the first approved oxazolidinone antibacterial agent, whereas PH027 is a novel compound of the same class that exhibits good in vitro antibacterial activity. The objective of this study was to develop an UPLC-MS/MS assay for the analysis of linezolid and PH027 in plasma and to apply the method for comparative pharmacokinetic and tissue distribution studies of both compounds. Plasma samples and calibrators were extracted with diethyl ether after addition of the internal standard solution. After evaporation of the ether layer, the residue was reconstituted in mobile phase and injected into UPLC-MS/MS. The mobile phase consisted of 2mM ammonium acetate buffer solution and acetonitrile (70:30) at a flow rate of 0.2ml/min. Separation was achieved using UPLC BEH C 18 column, and quantitative determination of the analytes was performed using multiple-reaction monitoring (MRM) scanning mode. The method was validated by analyzing quality control tissue homogenate samples, and was applied to analyze tissue homogenate samples obtained following IV injections of linezolid and PH027 in rabbits. The developed UPLC-MS/MS method was linear in the concentration range of 50-5000ng/ml. Validation of the method proved that the method's precision, selectivity and stability were all within the acceptable limits. Linezolid and PH027 concentrations were accurately determined in the quality control tissue homogenate samples, and analysis of samples obtained following IV administration of the two compounds showed that the tissue to plasma concentration ratio of PH027 was higher than that of linezolid probably due to its higher lipophilicity. The developed UPLC-MS/MS method for the analysis of linezolid and PH027 in rabbit's plasma can accurately determine the concentrations of these compounds in different tissues. Copyright © 2016 Elsevier B.V. All rights reserved.

  15. Improved circulating microparticle analysis in acid-citrate dextrose (ACD) anticoagulant tube.

    PubMed

    György, Bence; Pálóczi, Krisztina; Kovács, Alexandra; Barabás, Eszter; Bekő, Gabriella; Várnai, Katalin; Pállinger, Éva; Szabó-Taylor, Katalin; Szabó, Tamás G; Kiss, Attila A; Falus, András; Buzás, Edit I

    2014-02-01

    Recently extracellular vesicles (exosomes, microparticles also referred to as microvesicles and apoptotic bodies) have attracted substantial interest as potential biomarkers and therapeutic vehicles. However, analysis of microparticles in biological fluids is confounded by many factors such as the activation of cells in the blood collection tube that leads to in vitro vesiculation. In this study we aimed at identifying an anticoagulant that prevents in vitro vesiculation in blood plasma samples. We compared the levels of platelet microparticles and non-platelet-derived microparticles in platelet-free plasma samples of healthy donors. Platelet-free plasma samples were isolated using different anticoagulant tubes, and were analyzed by flow cytometry and Zymuphen assay. The extent of in vitro vesiculation was compared in citrate and acid-citrate-dextrose (ACD) tubes. Agitation and storage of blood samples at 37 °C for 1 hour induced a strong release of both platelet microparticles and non-platelet-derived microparticles. Strikingly, in vitro vesiculation related to blood sample handling and storage was prevented in samples in ACD tubes. Importantly, microparticle levels elevated in vivo remained detectable in ACD tubes. We propose the general use of the ACD tube instead of other conventional anticoagulant tubes for the assessment of plasma microparticles since it gives a more realistic picture of the in vivo levels of circulating microparticles and does not interfere with downstream protein or RNA analyses. Copyright © 2013 Elsevier Ltd. All rights reserved.

  16. Effects of female bovine plasma collected at different days of the estrous cycle on epididymal spermatozoa motility.

    PubMed

    Nait Mouloud, M; Ouennoughi, F; Yaiche, L; Kaidi, R; Iguer-Ouada, M

    2017-03-15

    The aim of this study was to assess the effects of female bovine plasma collected at different days of the reproductive cycle on epididymal spermatozoa motility and to test hypothesis that the subpopulations pattern of motile spermatozoa is affected by this treatment. Blood plasma samples were collected from five Holstein Friesian cows at different stages of the estrous cycle (days 0, 5, 10, 12 and 18), one pregnant cow and one adult bull and were diluted 1:9 (V/V) with normal saline. Female charcoal-treated plasma, Bull plasma and saline were used as controls. Semen samples were obtained from cauda epididymidis through retrograde flushing and diluted in saline to approximately 60 × 106 sperm/ml. The extended semen was diluted 1:2 (V/V) with tested media and motility was evaluated at 15 min and then every hour for 6 h using a computer-assisted semen analysis. Multivariate clustering procedure was applied to identify and quantify specific subpopulations within the semen samples. The statistical analysis clustered all the motile spermatozoa into three separate subpopulations with defined patterns of movement: Subpopulation 1 poorly motile and non-progressive spermatozoa (39.3%), subpopulation 2 including the fastest and the most vigorous spermatozoa (46.4%) and subpopulation 3 represented by slow, non-vigorous but linear spermatozoa (14.3%). Initially, sperm samples supplemented with female, male or female charcoal-treated plasma stimulated equally total motility and spermatozoa belonging to subpopulation 2 regardless of the estrous cycle stage. After 1-h incubation, the motility of these both categories of spermatozoa (total motile and those assigned to subpopulation 2) is enhanced and maintained more in day 12, 18 and pregnant cow plasma than in female plasma from earlier stage of the estrous cycle (day 0, 5 and 10), male plasma and female-charcoal treated plasma. In conclusion, the overall results showed that female plasma stimulated significantly sperm motility, especially at the late stage of the estrous cycle. Additionally, to the diverse compounds contained in blood plasma, progesterone may play a key role in such motility activation. Copyright © 2016 Elsevier Inc. All rights reserved.

  17. Metal-Assisted Laser-Induced Gas Plasma for the Direct Analysis of Powder Using Pulse CO2 Laser

    NASA Astrophysics Data System (ADS)

    Khumaeni, A.; Lie, Z. S.; Kurniawan, K. H.; Kagawa, K.

    2017-01-01

    Analysis of powder samples available in small quantities has been carried out using metal-assisted gas plasma by utilizing a transversely excited atmospheric (TEA) CO2 laser. The powder was homogeneously mixed with Si grease, and the mixed powder was painted on a metal subtarget. When a TEA CO2 laser was directly focused on the metal subtarget at atmospheric pressure of He gas, a high-temperature He gas plasma was induced. It is assumed that the powder particles were vaporized to be effectively atomized and excited in the gas plasma region. This method has been employed in the rapid analyses of elements in organic and inorganic powder samples present in small quantities. Detection of trace elements of Cr and Pb has been successfully made by using the supplement powder and loam soil, respectively. The detection limits of Pb in loam soil were approximately 20 mg/kg.

  18. Quantitative analysis of [Dmt(1)]DALDA in ovine plasma by capillary liquid chromatography-nanospray ion-trap mass spectrometry.

    PubMed

    Wan, Haibao; Umstot, Edward S; Szeto, Hazel H; Schiller, Peter W; Desiderio, Dominic M

    2004-04-15

    The synthetic opioid peptide analog Dmt-D-Arg-Phe-Lys-NH(2) ([Dmt(1)]DALDA; [Dmt= 2',6'-dimethyltyrosine) is a highly potent and selective mu opioid-receptor agonist. A very sensitive and robust capillary liquid chromatography/nanospray ion-trap (IT) mass spectrometry method has been developed to quantify [Dmt(1)]DALDA in ovine plasma, using deuterated [Dmt(1)]DALDA as the internal standard. The standard MS/MS spectra of d(0)- and d(5)-[Dmt(1)]DALDA were obtained, and the collision energy was experimentally optimized to 25%. The product ion [ M + 2H-NH(3)](2+) (m/z 312.2) was used to identify and to quantify the synthetic opioid peptide analog in ovine plasma samples. The MS/MS detection sensitivity for [Dmt(1)]DALDA was 625 amol. A calibration curve was constructed, and quantitative analysis was performed on a series of ovine plasma samples.

  19. Isolation of Circulating Plasma Cells in Multiple Myeloma Using CD138 Antibody-Based Capture in a Microfluidic Device

    NASA Astrophysics Data System (ADS)

    Qasaimeh, Mohammad A.; Wu, Yichao C.; Bose, Suman; Menachery, Anoop; Talluri, Srikanth; Gonzalez, Gabriel; Fulciniti, Mariateresa; Karp, Jeffrey M.; Prabhala, Rao H.; Karnik, Rohit

    2017-04-01

    The necessity for bone marrow aspiration and the lack of highly sensitive assays to detect residual disease present challenges for effective management of multiple myeloma (MM), a plasma cell cancer. We show that a microfluidic cell capture based on CD138 antigen, which is highly expressed on plasma cells, permits quantitation of rare circulating plasma cells (CPCs) in blood and subsequent fluorescence-based assays. The microfluidic device is based on a herringbone channel design, and exhibits an estimated cell capture efficiency of ~40-70%, permitting detection of <10 CPCs/mL using 1-mL sample volumes, which is difficult using existing techniques. In bone marrow samples, the microfluidic-based plasma cell counts exhibited excellent correlation with flow cytometry analysis. In peripheral blood samples, the device detected a baseline of 2-5 CD138+ cells/mL in healthy donor blood, with significantly higher numbers in blood samples of MM patients in remission (20-24 CD138+ cells/mL), and yet higher numbers in MM patients exhibiting disease (45-184 CD138+ cells/mL). Analysis of CPCs isolated using the device was consistent with serum immunoglobulin assays that are commonly used in MM diagnostics. These results indicate the potential of CD138-based microfluidic CPC capture as a useful ‘liquid biopsy’ that may complement or partially replace bone marrow aspiration.

  20. Neutron-Irradiated Samples as Test Materials for MPEX

    DOE PAGES

    Ellis, Ronald James; Rapp, Juergen

    2015-10-09

    Plasma Material Interaction (PMI) is a major concern in fusion reactor design and analysis. The Material-Plasma Exposure eXperiment (MPEX) will explore PMI under fusion reactor plasma conditions. Samples with accumulated displacements per atom (DPA) damage produced by fast neutron irradiations in the High Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory (ORNL) will be studied in the MPEX facility. This paper presents assessments of the calculated induced radioactivity and resulting radiation dose rates of a variety of potential fusion reactor plasma-facing materials (such as tungsten). The scientific code packages MCNP and SCALE were used to simulate irradiation of themore » samples in HFIR including the generation and depletion of nuclides in the material and the subsequent composition, activity levels, gamma radiation fields, and resultant dose rates as a function of cooling time. A challenge of the MPEX project is to minimize the radioactive inventory in the preparation of the samples and the sample dose rates for inclusion in the MPEX facility.« less

  1. Some Rare Earth Elements Analysis by Microwave Plasma Torch Coupled with the Linear Ion Trap Mass Spectrometry

    PubMed Central

    Xiong, Xiaohong; Jiang, Tao; Qi, Wenhao; Zuo, Jun; Yang, Meiling; Fei, Qiang; Xiao, Saijin; Yu, Aimin; Zhu, Zhiqiang; Chen, Huanwen

    2015-01-01

    A sensitive mass spectrometric analysis method based on the microwave plasma technique is developed for the fast detection of trace rare earth elements (REEs) in aqueous solution. The plasma was produced from a microwave plasma torch (MPT) under atmospheric pressure and was used as ambient ion source of a linear ion trap mass spectrometer (LTQ). Water samples were directly pneumatically nebulized to flow into the plasma through the central tube of MPT. For some REEs, the generated composite ions were detected in both positive and negative ion modes and further characterized in tandem mass spectrometry. Under the optimized conditions, the limit of detection (LOD) was at the level 0.1 ng/mL using MS2 procedure in negative mode. A single REE analysis can be completed within 2~3 minutes with the relative standard deviation ranging between 2.4% and 21.2% (six repeated measurements) for the 5 experimental runs. Moreover, the recovery rates of these REEs are between the range of 97.6%–122.1%. Two real samples have also been analyzed, including well and orange juice. These experimental data demonstrated that this method is a useful tool for the field analysis of REEs in water and can be used as an alternative supplement of ICP-MS. PMID:26421013

  2. Development of plasma-on-chip: Plasma treatment for individual cells cultured in media

    NASA Astrophysics Data System (ADS)

    Kumagai, Shinya; Chang, Chun-Yao; Jeong, Jonghyeon; Kobayashi, Mime; Shimizu, Tetsuji; Sasaki, Minoru

    2016-01-01

    A device consisting of Si microwells and microplasma sources has been fabricated for plasma treatment of individual cells cultured in media. We named the device plasma-on-chip. The microwells have through-holes at the bottom where gas-liquid interfaces form when they are filled with media containing biological samples. The microplasma sources, which supply reactive species, are located on the back of each microwell. Through the gas-liquid interface, the reactive species are supplied to the cells. Chlorella cells were used to demonstrate the feasibility of the device and after three minutes of plasma treatment, the fluorescence intensity of Chlorella cells appeared to be decreased. Optical emission spectroscopy identified O and OH radicals in the plasma, which can affect the cells. In the analysis of biological samples such as human cells or tissues, this device raises the possibility of revealing the mechanisms of plasma medicine in more detail.

  3. Fully automated method for the liquid chromatographic determination of cyproterone acetate in plasma using restricted access material for sample pre-treatment.

    PubMed

    Christiaens, B; Chiap, P; Rbeida, O; Cello, D; Crommen, J; Hubert, Ph

    2003-09-25

    A new fully automated method for the quantitative analysis of an antiandrogenic substance, cyproterone acetate (CPA), in plasma samples has been developed using on-line solid-phase extraction (SPE) prior to the determination by reversed-phase liquid chromatography (LC). The automated method was based on the use of a precolumn packed with an internal-surface reversed-phase packing material (LiChrospher RP-4 ADS) for sample clean-up coupled to LC analysis on an octadecyl stationary phase using a column-switching system. A 200-microL volume of plasma sample was injected directly on the precolumn packed with restricted access material using a mixture of water-acetonitrile (90:10, v/v) as washing liquid. The analyte was then eluted in the back-flush mode with the LC mobile phase which consisted of a mixture of phosphate buffer, pH 7.0-acetonitrile (54:46, v/v). The elution profiles of CPA and blank plasma samples on the precolumn and the time needed for analyte transfer from the precolumn to the analytical column were determined. Different compositions of washing liquid and mobile phase were tested to reduce the interference of plasma endogenous components. UV detection was achieved at 280 nm. Finally, the developed method was validated using a new approach, namely the application of the accuracy profile based on the interval confidence at 90% of the total measurement error (bias+standard deviation). The limit of quantification of cyproterone acetate in plasma was determined at 15 ng mL(-1). The validated method should be applicable to the determination of CPA in patients treated by at least 50 mg day(-1).

  4. Interlaboratory trial for the measurement of total cobalt in equine urine and plasma by ICP-MS.

    PubMed

    Popot, Marie-Agnes; Ho, Emmie N M; Stojiljkovic, Natali; Bagilet, Florian; Remy, Pierre; Maciejewski, Pascal; Loup, Benoit; Chan, George H M; Hargrave, Sabine; Arthur, Rick M; Russo, Charlie; White, James; Hincks, Pamela; Pearce, Clive; Ganio, George; Zahra, Paul; Batty, David; Jarrett, Mark; Brooks, Lydia; Prescott, Lise-Anne; Bailly-Chouriberry, Ludovic; Bonnaire, Yves; Wan, Terence S M

    2017-09-01

    Cobalt is an essential mineral micronutrient and is regularly present in equine nutritional and feed supplements. Therefore, cobalt is naturally present at low concentrations in biological samples. The administration of cobalt chloride is considered to be blood doping and is thus prohibited. To control the misuse of cobalt, it was mandatory to establish an international threshold for cobalt in plasma and/or in urine. To achieve this goal, an international collaboration, consisting of an interlaboratory comparison between 5 laboratories for the urine study and 8 laboratories for the plasma study, has been undertaken. Quantification of cobalt in the biological samples was performed by inductively coupled plasma-mass spectrometry (ICP-MS). Ring tests were based on the analysis of 5 urine samples supplemented at concentrations ranging from 5 up to 500 ng/mL and 5 plasma samples spiked at concentrations ranging from 0.5 up to 25 ng/mL. The results obtained from the different laboratories were collected, compiled, and compared to assess the reproducibility and robustness of cobalt quantification measurements. The statistical approach for the ring test for total cobalt in urine was based on the determination of percentage deviations from the calculated means, while robust statistics based on the calculated median were applied to the ring test for total cobalt in plasma. The inter-laboratory comparisons in urine and in plasma were successful so that 97.6% of the urine samples and 97.5% of the plasma samples gave satisfactory results. Threshold values for cobalt in plasma and urine were established from data only obtained by laboratories involved in the ring test. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.

  5. Modification of W surfaces by exposure to hollow cathode plasmas

    NASA Astrophysics Data System (ADS)

    Stancu, C.; Stokker-Cheregi, F.; Moldovan, A.; Dinescu, M.; Grisolia, C.; Dinescu, G.

    2017-10-01

    In this work, we assess the surface modifications induced on W samples following exposure to He and He/H2 radiofrequency plasmas in hollow cathode discharge configuration. Our study addresses issues that relate to the use of W in next-generation fusion reactors and, therefore, the investigation of W surface degradation following exposure and heating by plasmas to temperatures above 1000 °C is of practical importance. For these experiments, we used commercially available tungsten samples having areas of 30 × 15 mm and 0.1 mm thickness. The hollow cathode plasma was produced using a radiofrequency (RF) generator (13.56 MHz) between parallel plate electrodes. The W samples were mounted as one of the electrodes. The He and He/H2 plasma discharges had a combined effect of heating and bombardment of the W surfaces. The surface modifications were studied for discharge powers between 200 and 300 W, which resulted in the heating of the samples to temperatures between 950 and 1230 °C, respectively. The samples were weighed prior and after plasma exposure, and loss of mass was measured following plasma exposure times up to 90 min. The analysis of changes in surface morphology was carried out by optical microscopy, scanning electron microscopy and atomic force microscopy. Additionally, optical emission spectra of the respective plasmas were recorded from the region localized inside the hollow cathode gap. We discuss the influence of experimental parameters on the changes in surface morphology.

  6. Serum and Plasma Metabolomic Biomarkers for Lung Cancer.

    PubMed

    Kumar, Nishith; Shahjaman, Md; Mollah, Md Nurul Haque; Islam, S M Shahinul; Hoque, Md Aminul

    2017-01-01

    In drug invention and early disease prediction of lung cancer, metabolomic biomarker detection is very important. Mortality rate can be decreased, if cancer is predicted at the earlier stage. Recent diagnostic techniques for lung cancer are not prognosis diagnostic techniques. However, if we know the name of the metabolites, whose intensity levels are considerably changing between cancer subject and control subject, then it will be easy to early diagnosis the disease as well as to discover the drug. Therefore, in this paper we have identified the influential plasma and serum blood sample metabolites for lung cancer and also identified the biomarkers that will be helpful for early disease prediction as well as for drug invention. To identify the influential metabolites, we considered a parametric and a nonparametric test namely student׳s t-test as parametric and Kruskal-Wallis test as non-parametric test. We also categorized the up-regulated and down-regulated metabolites by the heatmap plot and identified the biomarkers by support vector machine (SVM) classifier and pathway analysis. From our analysis, we got 27 influential (p-value<0.05) metabolites from plasma sample and 13 influential (p-value<0.05) metabolites from serum sample. According to the importance plot through SVM classifier, pathway analysis and correlation network analysis, we declared 4 metabolites (taurine, aspertic acid, glutamine and pyruvic acid) as plasma biomarker and 3 metabolites (aspartic acid, taurine and inosine) as serum biomarker.

  7. 40 CFR Appendix C to Part 136 - Inductively Coupled Plasma-Atomic Emission Spectrometric Method for Trace Element Analysis of...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 22 2010-07-01 2010-07-01 false Inductively Coupled Plasma-Atomic... to Part 136—Inductively Coupled Plasma—Atomic Emission Spectrometric Method for Trace Element... technique. Samples are nebulized and the aerosol that is produced is transported to the plasma torch where...

  8. 40 CFR Appendix C to Part 136 - Inductively Coupled Plasma-Atomic Emission Spectrometric Method for Trace Element Analysis of...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 23 2011-07-01 2011-07-01 false Inductively Coupled Plasma-Atomic... to Part 136—Inductively Coupled Plasma—Atomic Emission Spectrometric Method for Trace Element... technique. Samples are nebulized and the aerosol that is produced is transported to the plasma torch where...

  9. Simultaneous analysis of thiamphenicol and its prodrug thiamphenicol glycinate in human plasma and urine by high performance liquid chromatography: application to pharmacokinetic study.

    PubMed

    Chen, Xijing; Yang, Bing; Ni, Liang; Wang, Guangji

    2006-06-07

    A simple and sensitive method for simultaneous determination of the active compound, thiamphenicol (TAP) and its prodrug, thiamphenicol glycinate (TG) in human plasma and urine is described. The procedure involved extraction of TG and TAP with ethyl acetate (plasma) or 100-fold dilution with the mobile phase (urine) followed by determination by reversed-phase high performance liquid chromatography (HPLC) with UV detection at 224 nm. Separation of the compounds was achieved on a column packed with Hypersil ODS2. The mobile phase consisted of acetonitrile-water containing 0.003 M tetrabutyl ammonium bromide and 0.056 M ammonium acetate (87:13, v/v) with a flow rate of 1.0 ml/min. The chromatograms did not contain interfering peaks due to the suitable extraction procedure and chromatographic conditions. The calibration curves of TG and TAP were linear ranging from 0.78 to 100 microg/ml in plasma and in urine. The intra-day and inter-day relative standard deviations (S.D.) were less than 10%. The recoveries of TG and TAP in plasma and urine were above 80%. TG was not stable in plasma samples and after extraction at ambient temperature or in freeze-thaw cycles, and hence the samples for injection on HPLC column should be stored in refrigerator or under ice cooling prior to analysis, and the plasma samples should not experience the freeze-thaw cycle more than one time. Unlike TAP, TG could not be detected in most urine samples. Application of this method demonstrated that it was feasible for the clinical pharmacokinetic study.

  10. Detection of EGFR Variants in Plasma: A Multilaboratory Comparison of the cobas EGFR Mutation Test v2 in Europe.

    PubMed

    Keppens, Cleo; Palma, John F; Das, Partha M; Scudder, Sidney; Wen, Wei; Normanno, Nicola; Van Krieken, J Han; Sacco, Alessandra; Fenizia, Francesca; de Castro, David Gonzalez; Hönigschnabl, Selma; Kern, Izidor; Lopez-Rios, Fernando; Lozano, Maria D; Marchetti, Antonio; Halfon, Philippe; Schuuring, Ed; Setinek, Ulrike; Sorensen, Boe; Taniere, Phillipe; Tiemann, Markus; Vosmikova, Hana; Dequeker, Elisabeth M C

    2018-04-25

    Molecular testing of EGFR is required to predict the response likelihood to targeted therapy in non-small-cell lung cancer. Analysis of circulating tumor DNA in plasma may complement limitations of tumor tissue. This study evaluated the interlaboratory performance and reproducibility of the cobas EGFR Mutation Test v2 to detect EGFR variants in plasma. Fourteen laboratories received two identical panels of 27 single-blinded plasma samples. Samples were wild-type or spiked with plasmid DNA to contain seven common EGFR variants at six predefined concentrations from 50 to 5000 copies per mL. The circulating tumor DNA was extracted by the cobas cfDNA Sample Preparation kit, followed by duplicate analysis with the EGFRv2 kit (Roche Molecular Systems, Pleasanton, CA). Lowest sensitivities were obtained for the c.2156G>C p.(Gly719Ala) and c.2573T>G p.(Leu858Arg) variants for the lowest target copies. For all other variants, sensitivities varied between 96.3% and 100.0%. Specificities were all 98.8% to 100.0%. Coefficients of variation indicated good intra and interlaboratory repeatability and reproducibility, but increased for decreasing concentrations. Prediction models revealed a significant correlation for all variants between the pre-defined copy number and the observed semiquantitative index values which reflects the samples' plasma mutation load. This study demonstrates an overall robust performance of the EGFRv2 kit in plasma. Prediction models may be applied to estimate the plasma mutation load for diagnostic or research purposes. Copyright © 2018 American Society for Investigative Pathology and the Association for Molecular Pathology. Published by Elsevier Inc. All rights reserved.

  11. Quantification of vosaroxin and its metabolites N-desmethylvosaroxin and O-desmethylvosaroxin in human plasma and urine using high-performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Nijenhuis, C M; Lucas, L; Rosing, H; Jamieson, G; Fox, J A; Schellens, J H M; Beijnen, J H

    2016-08-01

    Vosaroxin is a first-in-class anticancer quinolone derivative topoisomerase II inhibitor that is currently in development in combination with cytarabine for the treatment of acute myeloid leukemia (AML). To investigate vosaroxin pharmacokinetics (PK) in patients, liquid chromatography tandem mass spectrometry (LC-MS/MS) assays to quantify vosaroxin and the two metabolites N-desmethylvosaroxin and O-desmethylvosaroxin in human plasma and urine were developed and validated. Immediately after collection the samples were stored at -80°C. Prior to analysis, the plasma samples were subjected to protein precipitation and the urine samples were diluted. For both assays the reconstituted extracts were injected on a Symmetry Shield RP8 column and gradient elution was applied using 0.1% formic acid in water and acetonitrile-methanol (50:50, v/v). Analyses were performed with a triple quadruple mass spectrometer in positive-ion mode. A deuterated isotope of vosaroxin was used as internal standard for the quantification. The validated assays quantify vosaroxin and N-desmethylvosaroxin in the concentration range of 2-500ng/mL in plasma and urine. For O-desmethylvosaroxin the concentration range of 4-500ng/mL in plasma and urine was validated. Dilution integrity experiments show that samples can be diluted 25 fold in control matrix prior to analysis. The expanded concentration range for plasma and urine for vosaroxin and N-desmethylvosaroxin is therefore from 2 to 15,000ng/mL and in plasma for O-desmethylvosaroxin from 4 to 15,000ng/mL. Copyright © 2016 Elsevier B.V. All rights reserved.

  12. Bioanalysis works in the IAA AMS facility: Comparison of AMS analytical method with LSC method in human mass balance study

    NASA Astrophysics Data System (ADS)

    Miyaoka, Teiji; Isono, Yoshimi; Setani, Kaoru; Sakai, Kumiko; Yamada, Ichimaro; Sato, Yoshiaki; Gunji, Shinobu; Matsui, Takao

    2007-06-01

    Institute of Accelerator Analysis Ltd. (IAA) is the first Contract Research Organization in Japan providing Accelerator Mass Spectrometry (AMS) analysis services for carbon dating and bioanalysis works. The 3 MV AMS machines are maintained by validated analysis methods using multiple control compounds. It is confirmed that these AMS systems have reliabilities and sensitivities enough for each objective. The graphitization of samples for bioanalysis is prepared by our own purification lines including the measurement of total carbon content in the sample automatically. In this paper, we present the use of AMS analysis in human mass balance and metabolism profiling studies with IAA 3 MV AMS, comparing results obtained from the same samples with liquid scintillation counting (LSC). Human samples such as plasma, urine and feces were obtained from four healthy volunteers orally administered a 14C-labeled drug Y-700, a novel xanthine oxidase inhibitor, of which radioactivity was about 3 MBq (85 μCi). For AMS measurement, these samples were diluted 100-10,000-fold with pure-water or blank samples. The results indicated that AMS method had a good correlation with LSC method (e.g. plasma: r = 0.998, urine: r = 0.997, feces: r = 0.997), and that the drug recovery in the excreta exceeded 92%. The metabolite profiles of plasma, urine and feces obtained with HPLC-AMS corresponded to radio-HPLC results measured at much higher radioactivity level. These results revealed that AMS analysis at IAA is useful to measure 14C-concentration in bioanalysis studies at very low radioactivity level.

  13. A method for the direct injection and analysis of small volume human blood spots and plasma extracts containing high concentrations of organic solvents using revered-phase 2D UPLC/MS.

    PubMed

    Rainville, Paul D; Simeone, Jennifer L; Root, Dan S; Mallet, Claude R; Wilson, Ian D; Plumb, Robert S

    2015-03-21

    The emergence of micro sampling techniques holds great potential to improve pharmacokinetic data quality, reduce animal usage, and save costs in safety assessment studies. The analysis of these samples presents new challenges for bioanalytical scientists, both in terms of sample processing and analytical sensitivity. The use of two dimensional LC/MS with, at-column-dilution for the direct analysis of highly organic extracts prepared from biological fluids such as dried blood spots and plasma is demonstrated. This technique negated the need to dry down and reconstitute, or dilute samples with water/aqueous buffer solutions, prior to injection onto a reversed-phase LC system. A mixture of model drugs, including bromhexine, triprolidine, enrofloxacin, and procaine were used to test the feasibility of the method. Finally an LC/MS assay for the probe pharmaceutical rosuvastatin was developed from dried blood spots and protein-precipitated plasma. The assays showed acceptable recovery, accuracy and precision according to US FDA guidelines. The resulting analytical method showed an increase in assay sensitivity of up to forty fold as compared to conventional methods by maximizing the amount loaded onto the system and the MS response for the probe pharmaceutical rosuvastatin from small volume samples.

  14. A novel freeze-dried storage and preparation method for the determination of mycophenolic acid in plasma by high-performance liquid chromatography.

    PubMed

    Wang, Lei; Qiang, Wei; Li, Ying; Cheng, Zeneng; Xie, Mengmeng

    2017-09-01

    Plasma samples were conventionally stored at freezing conditions until the time of detection. Such a technique, when carried out over an extended period, is energy consuming; in addition, preparation and transportation of stored samples is inconvenient. In this study, a freeze-dried storage and preparation method was proposed to determine the presence of mycophenolic acid (MPA) in plasma. Fresh plasma samples were freeze-dried using a device, and then stored at ambient temperature. After the stored samples were soaked with methanol spiked with the internal standard, high-performance liquid chromatography was conducted to detect MPA. The proposed method was demonstrated to be precise and accurate over the linear range of 0.5-50 μg mL -1 , with both intra- and inter-day precision being <7% and biases <10%. The freeze-dried samples were stable at ambient temperature for at least 40 days. This method was also successfully applied to the pharmacokinetic study of MPA in healthy volunteers. Pharmacokinetic parameters, such as maximum plasma concentration, time point of maximum plasma concentration and elimination half-life, among others, were consistent with the results in the published study. This proposed technique was proved to be simple, reproducible and energy saving. This approach could also simplify the storage and analysis of samples in clinical and scientific drug research. Copyright © 2017 John Wiley & Sons, Ltd.

  15. Optimization of quantitative proteomic analysis of clots generated from plasma of patients with venous thromboembolism.

    PubMed

    Stachowicz, Aneta; Siudut, Jakub; Suski, Maciej; Olszanecki, Rafał; Korbut, Ryszard; Undas, Anetta; Wiśniewski, Jacek R

    2017-01-01

    It is well known that fibrin network binds a large variety of proteins, including inhibitors and activators of fibrinolysis, which may affect clot properties, such as stability and susceptibility to fibrinolysis. Specific plasma clot composition differs between individuals and may change in disease states. However, the plasma clot proteome has not yet been in-depth analyzed, mainly due to technical difficulty related to the presence of a highly abundant protein-fibrinogen and fibrin that forms a plasma clot. The aim of our study was to optimize quantitative proteomic analysis of fibrin clots prepared ex vivo from citrated plasma of the peripheral blood drawn from patients with prior venous thromboembolism (VTE). We used a multiple enzyme digestion filter aided sample preparation, a multienzyme digestion (MED) FASP method combined with LC-MS/MS analysis performed on a Proxeon Easy-nLC System coupled to the Q Exactive HF mass spectrometer. We also evaluated the impact of peptide fractionation with pipet-tip strong anion exchange (SAX) method on the obtained results. Our proteomic approach revealed 476 proteins repeatedly identified in the plasma fibrin clots from patients with VTE including extracellular vesicle-derived proteins, lipoproteins, fibrinolysis inhibitors, and proteins involved in immune responses. The MED FASP method using three different enzymes: LysC, trypsin and chymotrypsin increased the number of identified peptides and proteins and their sequence coverage as compared to a single step digestion. Peptide fractionation with a pipet-tip strong anion exchange (SAX) protocol increased the depth of proteomic analyses, but also extended the time needed for sample analysis with LC-MS/MS. The MED FASP method combined with a label-free quantification is an excellent proteomic approach for the analysis of fibrin clots prepared ex vivo from citrated plasma of patients with prior VTE.

  16. A rapid solid-phase extraction method for measurement of non-metabolised peripheral benzodiazepine receptor ligands, [(18)F]PBR102 and [(18)F]PBR111, in rat and primate plasma.

    PubMed

    Katsifis, Andrew; Loc'h, Christian; Henderson, David; Bourdier, Thomas; Pham, Tien; Greguric, Ivan; Lam, Peter; Callaghan, Paul; Mattner, Filomena; Eberl, Stefan; Fulham, Michael

    2011-01-01

    To develop a rapid and reliable method for estimating non-metabolised PBR ligands fluoroethoxy ([(18)F]PBR102)- and fluoropropoxy ([(18)F]PBR111)-substituted 2-(6-chloro-2-phenyl)imidazo[1,2-a]pyridine-3-yl)-N,N-diethylacetamides in plasma. Rats and baboons were imaged with PET up to 2 h postinjection of [(18)F]PBR102 and [(18)F]PBR111 under baseline conditions, after pre-blocking or displacement with PK11195. Arterial plasma samples were directly analysed by reverse-phase solid-phase extraction (RP-SPE) and RP-HPLC and by normal-phase TLC. SPE cartridges were successively washed with acetonitrile/water mixtures. SPE eluant radioactivity was measured in a γ-counter to determine the parent compound fraction and then analysed by HPLC and TLC for validation. In SPE, hydrophilic and lipophilic radiolabelled metabolites were eluted in water and 20% acetonitrile/water. All non-metabolised [(18)F]PBR102 and [(18)F]PBR111 were in SPE acetonitrile fraction as confirmed by HPLC and TLC analysis. Unchanged (%) [(18)F]PBR102 and [(18)F]PBR111 from SPE analysis in rat and baboon plasma agreed with those from HPLC and TLC analysis. In rats and baboons, the fraction of unchanged tracer followed a bi-exponential decrease, with half-lives of 7 to 10 min for the fast component and >80 min for the slow component for both tracers. Direct plasma SPE analysis of [(18)F]PBR102 and [(18)F]PBR111 can reliably estimate parent compound fraction. SPE was superior to HPLC for samples with low activity; it allows rapid and accurate metabolite analysis of a large number of plasma samples for improved estimation of metabolite-corrected input function during quantitative PET imaging studies. Crown Copyright © 2011. Published by Elsevier Inc. All rights reserved.

  17. Plasma immersion ion implantation for reducing metal ion release

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Diaz, C.; Garcia, J. A.; Maendl, S.

    Plasma immersion ion implantation of Nitrogen and Oxygen on CoCrMo alloys was carried out to improve the tribological and corrosion behaviors of these biomedical alloys. In order to optimize the implantation results we were carried experiments at different temperatures. Tribocorrosion tests in bovine serum were used to measure Co, Cr and Mo releasing by using Inductively Coupled Plasma Mass Spectrometry analysis after tests. Also, X-ray Diffraction analysis were employed in order to explain any obtained difference in wear rate and corrosion tests. Wear tests reveals important decreases in rate of more than one order of magnitude for the best treatment.more » Moreover decreases in metal release were found for all the implanted samples, preserving the same corrosion resistance of the unimplanted samples. Finally this paper gathers an analysis, in terms of implantation parameters and achieved properties for industrial implementation of these treatments.« less

  18. Automation of preparation of nonmetallic samples for analysis by atomic absorption and inductively coupled plasma spectrometry

    NASA Technical Reports Server (NTRS)

    Wittmann, A.; Willay, G.

    1986-01-01

    For a rapid preparation of solutions intended for analysis by inductively coupled plasma emission spectrometry or atomic absorption spectrometry, an automatic device called Plasmasol was developed. This apparatus used the property of nonwettability of glassy C to fuse the sample in an appropriate flux. The sample-flux mixture is placed in a composite crucible, then heated at high temperature, swirled until full dissolution is achieved, and then poured into a water-filled beaker. After acid addition, dissolution of the melt, and filling to the mark, the solution is ready for analysis. The analytical results obtained, either for oxide samples or for prereduced iron ores show that the solutions prepared with this device are undistinguished from those obtained by manual dissolutions done by acid digestion or by high temperature fusion. Preparation reproducibility and analytical tests illustrate the performance of Plasmasol.

  19. Investigating Uranium Concentrations in Groundwaters in the State of Idaho Using Kinetic Phosphorescence Analysis and Inductively Coupled Plasma Mass Spectrometry.

    PubMed

    Tkavadze, Levan; Dunker, Roy E; Brey, Richard R; Dudgeon, John

    2016-11-01

    The determination of uranium concentrations in natural water samples is of great interest due to the environmental consequences of this radionuclide. In this study, 380 groundwater samples from various locations within the state of Idaho were analyzed using two different techniques. The first method was Kinetic Phosphorescence Analysis (KPA), which gives the total uranium concentrations in water samples. The second analysis method was inductively coupled plasma mass spectrometry (ICP- MS). This method determines the total uranium concentration as well as the separate isotope concentrations of uranium. The U/U isotopic ratio was also measured for each sample to confirm that there was no depleted or enriched uranium present. The results were compared and mapped separately from each other. The study also found that in some areas of the state, natural uranium concentrations are relatively high.

  20. Preparation and analysis of standardized waste samples for Controlled Ecological Life Support Systems (CELSS)

    NASA Technical Reports Server (NTRS)

    Carden, J. L.; Browner, R.

    1982-01-01

    The preparation and analysis of standardized waste samples for controlled ecological life support systems (CELSS) are considered. Analysis of samples from wet oxidation experiments, the development of ion chromatographic techniques utilizing conventional high pressure liquid chromatography (HPLC) equipment, and an investigation of techniques for interfacing an ion chromatograph (IC) with an inductively coupled plasma optical emission spectrometer (ICPOES) are discussed.

  1. Determination of major elements by wavelength-dispersive X-ray fluorescence spectrometry and trace elements by inductively coupled plasma mass spectrometry in igneous rocks from the same fused sample (110 mg)

    NASA Astrophysics Data System (ADS)

    Amosova, Alena A.; Panteeva, Svetlana V.; Chubarov, Victor M.; Finkelshtein, Alexandr L.

    2016-08-01

    The fusion technique is proposed for simultaneous determination of 35 elements from the same sample. Only 110 mg of rock sample was used to obtain fused glasses for quantitative determination of 10 major elements by wavelength dispersive X-ray fluorescence analysis, 16 rare earth elements and some other trace elements by inductively coupled plasma mass spectrometry analysis. Fusion was performed with 1.1 g of lithium metaborate and LiBr solution as the releasing agent in platinum crucible in electric furnace at 1100 °C. The certified reference materials of ultramafic, mafic, intermediate and felsic igneous rocks have been applied to obtain the calibration curves for rock-forming oxides (Na2O, MgO, Al2O3, SiO2, P2O5, K2O, CaO, TiO2, MnO, Fe2O3) and some trace elements (Ba, Sr, Zr) determination by X-ray fluorescence analysis. The repeatability does not exceed the allowable standard deviation for a wide range of concentrations. In the most cases the relative standard deviation was less than 5%. Obtained glasses were utilized for the further determination of rare earth (La, Ce, Pr, Nd, Sm, Eu, Gd, Tb, Dy, Ho, Er, Tm, Yb, Lu) and some other (Ba, Sr, Zr, Rb, Cs, Y, Nb, Hf, Ta, Th and U) trace elements by inductively coupled plasma mass spectrometry analysis with the same certified reference materials employed. The results could mostly be accepted as satisfactory. The proposed procedure essentially reduces the expenses in comparison with separate sample preparation for inductively coupled plasma mass spectrometry and X-ray fluorescence analysis.

  2. Enantioselective analysis of ibuprofen in human plasma by anionic cyclodextrin-modified electrokinetic chromatography.

    PubMed

    Jabor, Valquíria A P; Lanchote, Vera L; Bonato, Pierina S

    2002-09-01

    This paper reports the development of a rapid method for the enantioselective analysis of the nonsteroidal anti-inflammatory drug ibuprofen in human plasma by capillary electrophoresis employing the anionic cyclodextrin-modified electrokinetic chromatography mode. Sample cleanup was carried out by acidification with HCl followed by liquid-liquid extraction with hexane:isopropanol (99:1 v/v). The complete enantioselective analysis was performed within 10 min, using 100 mmol L(-1) phosphoric acid/triethanolamine buffer, pH 2.6, containing 2.0% w/v sulfated beta-cyclodextrin as chiral selector; fenoprofen, another nonsteroidal anti-inflammatory drug, was used as internal standard. The calibration curves were linear over the concentration range of 0.25-125.0 microg mL(-1) for each enantiomer of ibuprofen. The mean recoveries for ibuprofen enantiomers were up to 85%. The enantiomers studied could be quantified at three different concentrations (0.5, 5.0 and 50.0 microg mL(-1)) with a coefficient of variation and relative error not higher than 15%. The quantitation limit was 0.2 microg mL(-1) for (+)-(S)- and (-)-(R)-ibuprofen using 1 mL of human plasma. The plasma endogenous compounds and other drugs did not interfere with the present assay. The analysis of real plasma samples obtained from a healthy volunteer after administration of 600 mg of racemic ibuprofen showed a maximum plasma level of 29.6 and 39.9 microg mL(-1) of (-)-(R)- and (+)-(S)-ibuprofen, respectively, and the area under plasma concentration-time curve AUC(0-infinity) (+)-(S)/AUC(0-infinity) (-)-(R) ratio was 1.87.

  3. Comparison of the quantification of acetaminophen in plasma, cerebrospinal fluid and dried blood spots using high-performance liquid chromatography-tandem mass spectrometry

    PubMed Central

    Taylor, Rachel R.; Hoffman, Keith L.; Schniedewind, Björn; Clavijo, Claudia; Galinkin, Jeffrey L.; Christians, Uwe

    2013-01-01

    Acetaminophen (paracetamol, N-(4-hydroxyphenyl) acetamide) is one of the most commonly prescribed drugs for the management of pain in children. Quantification of acetaminophen in pre-term and term neonates and small children requires the availability of highly sensitive assays in small volume blood samples. We developed and validated an LC-MS/MS assay for the quantification of acetaminophen in human plasma, cerebro-spinal fluid (CSF) and dried blood spots (DBS). Reconstitution in water (DBS only) and addition of a protein precipitation solution containing the deuterated internal standard were the only manual steps. Extracted samples were analyzed on a Kinetex 2.6 μm PFP column using an acetonitrile/formic acid gradient. The analytes were detected in the positive multiple reaction mode. Alternatively, DBS were automatically processed using direct desorption in a sample card and preparation (SCAP) robotic autosampler in combination with online extraction. The range of reliable response in plasma and CSF was 3.05-20,000 ng/ml (r2 > 0.99) and 27.4-20,000 ng/ml (r2 > 0.99) for DBS (manual extraction and automated direct desorption). Inter-day accuracy was always within 85-115% and inter-day precision for plasma, CSF and manually extracted DBS were less than 15%. Deming regression analysis comparing 167 matching pairs of plasma and DBS samples showed a correlation coefficient of 0.98. Bland Altman analysis indicated a 26.6% positive bias in DBS, most likely reflecting the blood: plasma distribution ratio of acetaminophen. DBS are a valid matrix for acetaminophen pharmacokinetic studies. PMID:23670126

  4. Comparison of plasma ammonia results from seven different automated platforms in use throughout Central Australia.

    PubMed

    Markus, Corey; Metz, Michael

    2017-04-01

    The clinical catchment area for the Metabolic service at the Women's and Children's Hospital in Adelaide, South Australia, covers nearly 2.5millionkm 2 . Care of children with metabolic disorders in these remote areas is assisted from Adelaide, and at times, using plasma ammonia results from laboratories up to 3000km away. There are seven different platforms measuring plasma ammonia within this vast clinical catchment area. Hence, a correlation study was conducted to examine the relationship between plasma ammonia results from the seven different platforms in use throughout central Australia. Multiple aliquots of plasma from remainder EDTA samples for haematological investigations were frozen. Samples were then dispatched on dry ice to the laboratories being correlated. At an agreed date and time correlation samples were thawed and plasma ammonia measured. Passing-Bablok regression analysis showed slopes ranging from 1.00 to 1.10 and y-intercepts ranging from -10μmol/L to 1μmol/L. Despite the absence of a reference method or reference material and troublesome pre-analytical effects in ammonia measurement, plasma ammonia results from the different platforms in general compare well. The study also demonstrates that samples for ammonia measurement can be transported over great distances and still correlate well. Furthermore, a common reference interval for plasma ammonia may be a possibility. Crown Copyright © 2016. Published by Elsevier Inc. All rights reserved.

  5. ctDNA Determination of EGFR Mutation Status in European and Japanese Patients with Advanced NSCLC: The ASSESS Study.

    PubMed

    Reck, Martin; Hagiwara, Koichi; Han, Baohui; Tjulandin, Sergei; Grohé, Christian; Yokoi, Takashi; Morabito, Alessandro; Novello, Silvia; Arriola, Edurne; Molinier, Olivier; McCormack, Rose; Ratcliffe, Marianne; Normanno, Nicola

    2016-10-01

    To offer patients with EGFR mutation-positive advanced NSCLC appropriate EGFR tyrosine kinase inhibitor treatment, mutation testing of tumor samples is required. However, tissue/cytologic samples are not always available or evaluable. The large, noninterventional diagnostic ASSESS study (NCT01785888) evaluated the utility of circulating free tumor-derived DNA (ctDNA) from plasma for EGFR mutation testing. ASSESS was conducted in 56 centers (in Europe and Japan). Eligible patients (with newly diagnosed locally advanced/metastatic treatment-naive advanced NSCLC) provided diagnostic tissue/cytologic and plasma samples. DNA extracted from tissue/cytologic samples was subjected to EGFR mutation testing using local practices; designated laboratories performed DNA extraction/mutation testing of blood samples. The primary end point was level of concordance of EGFR mutation status between matched tissue/cytologic and plasma samples. Of 1311 patients enrolled, 1288 were eligible. Concordance of mutation status in 1162 matched samples was 89% (sensitivity 46%, specificity 97%, positive predictive value 78%, and negative predictive value 90%). A group of 25 patients with apparent false-positive plasma results was overrepresented for cytologic samples, use of less sensitive tissue testing methodologies, and smoking habits associated with high EGFR mutation frequency, indicative of false-negative tumor results. In cases in which plasma and tumor samples were tested with identical highly sensitive methods, positive predictive value/sensitivity were generally improved. These real-world data suggest that ctDNA is a feasible sample for EGFR mutation analysis. It is important to conduct mutation testing of both tumor and plasma samples in specialized laboratories, using robust/sensitive methods to ensure that patients receive appropriate treatments that target the molecular features of their disease. Copyright © 2016 International Association for the Study of Lung Cancer. Published by Elsevier Inc. All rights reserved.

  6. Development and validation of a sensitive HPLC method for the quantification of HI-6 in guinea pig plasma and evaluated in domestic swine.

    PubMed

    Bohnert, Sara; Vair, Cory; Mikler, John

    2010-05-15

    A rapid and small volume assay to quantify HI-6 in plasma was developed to further the development and licensing of an intravenous formulation of HI-6. The objective of this method was to develop a sensitive and rapid assay that clearly resolved HI-6 and an internal standard in saline and plasma matrices. A fully validated method using ion-pair HPLC and 2-PAM as the internal standard fulfilled these requirements. Small plasma samples of 35 microL were extracted using acidification, filtration and neutralization. Linearity was shown for over 4 microg/mL to 1mg/mL with accuracy and precision within 6% relative error at the lower limit of detection. This method was utilized in the pharmacokinetic analysis HI-6 dichloride (2Cl) and HI-6 dimethane sulfonate (DMS) in anaesthetized guinea pigs and domestic swine following an intravenous bolus administration. From the resultant pharmacokinetic parameters a target plasma concentration of 100 microM was established and maintained in guinea pigs receiving an intravenous infusion. This validated method allows for the analysis of low volume samples, increased sample numbers and is applicable to the determination of pharmacokinetic profiles and parameters. Copyright (c) 2010. Published by Elsevier B.V.

  7. Effects of Sample Handling and Analytical Procedures on Thyroid Hormone Concentrations in Pregnant Women's Plasma.

    PubMed

    Villanger, Gro Dehli; Learner, Emily; Longnecker, Matthew P; Ask, Helga; Aase, Heidi; Zoeller, R Thomas; Knudsen, Gun P; Reichborn-Kjennerud, Ted; Zeiner, Pål; Engel, Stephanie M

    2017-05-01

    Maternal thyroid function is a critical mediator of fetal brain development. Pregnancy-related physiologic changes and handling conditions of blood samples may influence thyroid hormone biomarkers. We investigated the reliability of thyroid hormone biomarkers in plasma of pregnant women under various handling conditions. We enrolled 17 pregnant women; collected serum and plasma were immediately frozen. Additional plasma aliquots were subjected to different handling conditions before the analysis of thyroid biomarkers: storage at room temperature for 24 or 48 hours before freezing and an extra freeze-thaw cycle. We estimated free thyroid hormone indices in plasma based on T3 uptake. High correlations between plasma and serum (>0.94) and intraclass correlation coefficients for plasma handling conditions (0.96 to 1.00) indicated excellent reliability for all thyroid hormone biomarkers. Delayed freezing and freeze-thaw cycles did not affect reliability of biomarkers of thyroid function in plasma during pregnancy. See video abstract at, http://links.lww.com/EDE/B180.

  8. Determination of modafinil in plasma and urine by reversed phase high-performance liquid-chromatography.

    PubMed

    Schwertner, Harvey A; Kong, Suk Bin

    2005-03-09

    Modafinil (Provigil) is a new wake-promoting drug that is being used for the management of excessive sleepiness in patients with narcolepsy. It has pharmacological properties similar to that of amphetamine, but without some of the side effects associated with amphetamine-like stimulants. Since modafinil has the potential to be abused, accurate drug-screening methods are needed for its analysis. In this study, we developed a high-performance liquid-chromatographic procedure (HPLC) for the quantitative analysis of modafinil in plasma and urine. (Phenylthio)acetic acid was used as an internal standard for the analysis of both plasma and urine. Modafinil was extracted from urine and plasma with ethyl acetate and ethyl acetate-acetic acid (100:1, v/v), respectively, and analyzed on a C18 reverse phase column with methanol-water-acetic acid (500:500:1, v/v) as the mobile phase. Recoveries from urine and plasma were 80.0 and 98.9%, respectively and the limit of quantitation was 0.1 microg/mL at 233 nm. Forty-eight 2-h post-dose urine samples from sham controls and from individuals taking 200 or 400 mg of modafinil were analyzed without knowledge of drug administration. All 16-placebo urine samples and all 32 2-h post-dose urine samples were correctly classified. The analytical procedure is accurate and reproducible and can be used for therapeutic drug monitoring, pharmacokinetic studies, and drug abuse screening.

  9. Metabolic Signature of Remote Ischemic Preconditioning Involving a Cocktail of Amino Acids and Biogenic Amines.

    PubMed

    Chao de la Barca, Juan Manuel; Bakhta, Oussama; Kalakech, Hussein; Simard, Gilles; Tamareille, Sophie; Catros, Véronique; Callebert, Jacques; Gadras, Cédric; Tessier, Lydie; Reynier, Pascal; Prunier, Fabrice; Mirebeau-Prunier, Delphine

    2016-09-24

    Remote ischemic preconditioning (RIPC) is an attractive therapeutic procedure for protecting the heart against ischemia/reperfusion injury. Despite evidence of humoral mediators transported through the circulation playing a critical role, their actual identities so far remain unknown. We sought to identify plasmatic RIPC-induced metabolites that may play a role. Rat plasma samples from RIPC and control groups were analyzed using a targeted metabolomic approach aimed at measuring 188 metabolites. Principal component analysis and orthogonal partial least-squares discriminant analysis were used to identify the metabolites that discriminated between groups. Plasma samples from 50 patients subjected to RIPC were secondarily explored to confirm the results obtained in rats. Finally, a combination of the metabolites that were significantly increased in both rat and human plasma was injected prior to myocardial ischemia/reperfusion in rats. In the rat samples, 124 molecules were accurately quantified. Six metabolites (ornithine, glycine, kynurenine, spermine, carnosine, and serotonin) were the most significant variables for marked differentiation between the RIPC and control groups. In human plasma, analysis confirmed ornithine decrease and kynurenine and glycine increase following RIPC. Injection of the glycine and kynurenine alone or in combination replicated the protective effects of RIPC seen in rats. We have hereby reported significant variations in a cocktail of amino acids and biogenic amines after remote ischemic preconditioning in both rat and human plasma. URL: http://www.clinicaltrials.gov. Unique identifier: NCT01390129. © 2016 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley Blackwell.

  10. Easy, Fast, and Reproducible Quantification of Cholesterol and Other Lipids in Human Plasma by Combined High Resolution MSX and FTMS Analysis

    NASA Astrophysics Data System (ADS)

    Gallego, Sandra F.; Højlund, Kurt; Ejsing, Christer S.

    2018-01-01

    Reliable, cost-effective, and gold-standard absolute quantification of non-esterified cholesterol in human plasma is of paramount importance in clinical lipidomics and for the monitoring of metabolic health. Here, we compared the performance of three mass spectrometric approaches available for direct detection and quantification of cholesterol in extracts of human plasma. These approaches are high resolution full scan Fourier transform mass spectrometry (FTMS) analysis, parallel reaction monitoring (PRM), and novel multiplexed MS/MS (MSX) technology, where fragments from selected precursor ions are detected simultaneously. Evaluating the performance of these approaches in terms of dynamic quantification range, linearity, and analytical precision showed that the MSX-based approach is superior to that of the FTMS and PRM-based approaches. To further show the efficacy of this approach, we devised a simple routine for extensive plasma lipidome characterization using only 8 μL of plasma, using a new commercially available ready-to-spike-in mixture with 14 synthetic lipid standards, and executing a single 6 min sample injection with combined MSX analysis for cholesterol quantification and FTMS analysis for quantification of sterol esters, glycerolipids, glycerophospholipids, and sphingolipids. Using this simple routine afforded reproducible and absolute quantification of 200 lipid species encompassing 13 lipid classes in human plasma samples. Notably, the analysis time of this procedure can be shortened for high throughput-oriented clinical lipidomics studies or extended with more advanced MSALL technology (Almeida R. et al., J. Am. Soc. Mass Spectrom. 26, 133-148 [1]) to support in-depth structural elucidation of lipid molecules. [Figure not available: see fulltext.

  11. Easy, Fast, and Reproducible Quantification of Cholesterol and Other Lipids in Human Plasma by Combined High Resolution MSX and FTMS Analysis.

    PubMed

    Gallego, Sandra F; Højlund, Kurt; Ejsing, Christer S

    2018-01-01

    Reliable, cost-effective, and gold-standard absolute quantification of non-esterified cholesterol in human plasma is of paramount importance in clinical lipidomics and for the monitoring of metabolic health. Here, we compared the performance of three mass spectrometric approaches available for direct detection and quantification of cholesterol in extracts of human plasma. These approaches are high resolution full scan Fourier transform mass spectrometry (FTMS) analysis, parallel reaction monitoring (PRM), and novel multiplexed MS/MS (MSX) technology, where fragments from selected precursor ions are detected simultaneously. Evaluating the performance of these approaches in terms of dynamic quantification range, linearity, and analytical precision showed that the MSX-based approach is superior to that of the FTMS and PRM-based approaches. To further show the efficacy of this approach, we devised a simple routine for extensive plasma lipidome characterization using only 8 μL of plasma, using a new commercially available ready-to-spike-in mixture with 14 synthetic lipid standards, and executing a single 6 min sample injection with combined MSX analysis for cholesterol quantification and FTMS analysis for quantification of sterol esters, glycerolipids, glycerophospholipids, and sphingolipids. Using this simple routine afforded reproducible and absolute quantification of 200 lipid species encompassing 13 lipid classes in human plasma samples. Notably, the analysis time of this procedure can be shortened for high throughput-oriented clinical lipidomics studies or extended with more advanced MS ALL technology (Almeida R. et al., J. Am. Soc. Mass Spectrom. 26, 133-148 [1]) to support in-depth structural elucidation of lipid molecules. Graphical Abstract ᅟ.

  12. Method and system of Jones-matrix mapping of blood plasma films with "fuzzy" analysis in differentiation of breast pathology changes

    NASA Astrophysics Data System (ADS)

    Zabolotna, Natalia I.; Radchenko, Kostiantyn O.; Karas, Oleksandr V.

    2018-01-01

    A fibroadenoma diagnosing of breast using statistical analysis (determination and analysis of statistical moments of the 1st-4th order) of the obtained polarization images of Jones matrix imaginary elements of the optically thin (attenuation coefficient τ <= 0,1 ) blood plasma films with further intellectual differentiation based on the method of "fuzzy" logic and discriminant analysis were proposed. The accuracy of the intellectual differentiation of blood plasma samples to the "norm" and "fibroadenoma" of breast was 82.7% by the method of linear discriminant analysis, and by the "fuzzy" logic method is 95.3%. The obtained results allow to confirm the potentially high level of reliability of the method of differentiation by "fuzzy" analysis.

  13. Clinical Validation of Therapeutic Drug Monitoring of Imipenem in Spent Effluent in Critically Ill Patients Receiving Continuous Renal Replacement Therapy: A Pilot Study.

    PubMed

    Wen, Aiping; Li, Zhe; Yu, Junxian; Li, Ren; Cheng, Sheng; Duan, Meili; Bai, Jing

    2016-01-01

    The primary objective of this pilot study was to investigate whether the therapeutic drug monitoring of imipenem could be performed with spent effluent instead of blood sampling collected from critically ill patients under continuous renal replacement therapy. A prospective open-label study was conducted in a real clinical setting. Both blood and effluent samples were collected pairwise before imipenem administration and 0.5, 1, 1.5, 2, 3, 4, 6, and 8 h after imipenem administration. Plasma and effluent imipenem concentrations were determined by reversed-phase high-performance liquid chromatography with ultraviolet detection. Pharmacokinetic and pharmacodynamic parameters of blood and effluent samples were calculated. Eighty-three paired plasma and effluent samples were obtained from 10 patients. The Pearson correlation coefficient of the imipenem concentrations in plasma and effluent was 0.950 (P<0.0001). The average plasma-to-effluent imipenem concentration ratio was 1.044 (95% confidence interval, 0.975 to 1.114) with Bland-Altman analysis. No statistically significant difference was found in the pharmacokinetic and pharmacodynamic parameters tested in paired plasma and effluent samples with Wilcoxon test. Spent effluent of continuous renal replacement therapy could be used for therapeutic drug monitoring of imipenem instead of blood sampling in critically ill patients.

  14. Determining the fatty acid composition in plasma and tissues as fatty acid methyl esters using gas chromatography – a comparison of different derivatization and extraction procedures.

    PubMed

    Ostermann, Annika I; Müller, Maike; Willenberg, Ina; Schebb, Nils Helge

    2014-12-01

    Analysis of the fatty acid (FA) composition in biological samples is commonly carried out using gas liquid chromatography (GC) after transesterification to volatile FA methyl esters (FAME). We compared the efficacy of six frequently used protocols for derivatization of different lipid classes as well as for plasma and tissue samples. Transesterification with trimethylsulfonium hydroxide (TMSH) led to insufficient derivatization efficacies for polyunsaturated FAs (PUFA, <50%). Derivatization in presence of potassium hydroxide (KOH) failed at derivatizing free FAs (FFAs). Boron trifluoride (BF3) 7% in hexane/MeOH (1:1) was insufficient for the transesterification of cholesterol ester (CE) as well as triacylglycerols (TGs). In contrast, methanolic hydrochloric acid (HCl) as well as a combination of BF3 with methanolic sodium hydroxide (NaOH+BF3) were suitable for the derivatization of FFAs, polar lipids, TGs, and CEs (derivatization rate >80% for all tested lipids). Regarding plasma samples, all methods led to an overall similar relative FA pattern. However, significant differences were observed, for example, for the relative amount of EPA+DHA (n3-index). Absolute FA plasma concentrations differed considerably among the methods, with low yields for KOH and BF3. We also demonstrate that lipid extraction with tert-butyl methyl ether/methanol (MTBE/MeOH) is as efficient as the classical method according to Bligh and Dyer, making it possible to replace (environmentally) toxic chloroform.We conclude that HCl-catalyzed derivatization in combination with MeOH/MTBE extraction is the most appropriate among the methods tested for the analysis of FA concentrations and FA pattern in small biological samples. A detailed protocol for the analysis of plasma and tissues is included in this article.

  15. The Effects of Gas Composition on the Atmospheric Pressure Plasma Jet Modification of Polyethylene Films

    NASA Astrophysics Data System (ADS)

    Sun, Jie; Qiu, Yiping

    2015-05-01

    Polyethylene (PE) films are treated using an atmospheric pressure plasma jet (APPJ) with He or He/O2 gas for different periods of time. The influence of gas type on the plasma-polymer interactions is studied. The surface contact angle of the PE film can be effectively lowered to 58° after 20 s of He/O2 plasma treatment and then remains almost unchanged for longer treatment durations, while, for He plasma treatment, the film surface contact angle drops gradually to 47° when the time reaches 120 s. Atomic force microscopy (AFM) results show that the root mean square (RMS) roughness was significantly higher for the He/O2 plasma treated samples than for the He plasma treated counterparts, and the surface topography of the He/O2 plasma treated PE films displays evenly distributed dome-shaped small protuberances. Chemical composition analysis reveals that the He plasma treated samples have a higher oxygen content but a clearly lower percentage of -COO than the comparable He/O2 treated samples, suggesting that differences exist in the mode of incorporating oxygen between the two gas condition plasma treatments. Electron spin resonance (ESR) results show that the free radical concentrations of the He plasma treated samples were clearly higher than those of the He/O2 plasma treated ones with other conditions unchanged. supported by the Fundamental Research Funds for the Central Universities of China (Nos. JUSRP1044 and JUSRP1045), National Natural Science Foundation of China (Nos. 51203062 and 51302110), and the Cooperative Innovation Fund, Project of Jiangsu Province, China (Nos. BY2012064, BY2013015-31 and BY2013015-32)

  16. Elemental profiling and geographical differentiation of Ethiopian coffee samples through inductively coupled plasma-optical emission spectroscopy (ICP-OES), ICP-mass spectrometry (ICP-MS) and direct mercury analyzer (DMA).

    PubMed

    Habte, Girum; Hwang, In Min; Kim, Jae Sung; Hong, Joon Ho; Hong, Young Sin; Choi, Ji Yeon; Nho, Eun Yeong; Jamila, Nargis; Khan, Naeem; Kim, Kyong Su

    2016-12-01

    This study was aimed to establish the elemental profiling and provenance of coffee samples collected from eleven major coffee producing regions of Ethiopia. A total of 129 samples were analyzed for forty-five elements using inductively coupled plasma (ICP)-optical emission spectroscopy (OES), ICP-mass spectrometry (MS) and direct mercury analyzer (DMA). Among the macro elements, K showed the highest levels whereas Fe was found to have the lowest concentration values. In all the samples, Ca, K, Mg, P and S contents were statistically significant (p<0.05). Micro elements showed the concentrations order of: Mn>Cu>Sr>Zn>Rb>Ni>B. Contents of the trace elements were lower than the permissible standard values. Inter-regions differentiation by cluster analysis (CA), linear discriminant analysis (LDA) and principal component analysis (PCA) showed that micro and trace elements are the best chemical descriptors of the analyzed coffee samples. Copyright © 2016 Elsevier Ltd. All rights reserved.

  17. Total Extracellular Small RNA Profiles from Plasma, Saliva, and Urine of Healthy Subjects

    PubMed Central

    Yeri, Ashish; Courtright, Amanda; Reiman, Rebecca; Carlson, Elizabeth; Beecroft, Taylor; Janss, Alex; Siniard, Ashley; Richholt, Ryan; Balak, Chris; Rozowsky, Joel; Kitchen, Robert; Hutchins, Elizabeth; Winarta, Joseph; McCoy, Roger; Anastasi, Matthew; Kim, Seungchan; Huentelman, Matthew; Van Keuren-Jensen, Kendall

    2017-01-01

    Interest in circulating RNAs for monitoring and diagnosing human health has grown significantly. There are few datasets describing baseline expression levels for total cell-free circulating RNA from healthy control subjects. In this study, total extracellular RNA (exRNA) was isolated and sequenced from 183 plasma samples, 204 urine samples and 46 saliva samples from 55 male college athletes ages 18–25 years. Many participants provided more than one sample, allowing us to investigate variability in an individual’s exRNA expression levels over time. Here we provide a systematic analysis of small exRNAs present in each biofluid, as well as an analysis of exogenous RNAs. The small RNA profile of each biofluid is distinct. We find that a large number of RNA fragments in plasma (63%) and urine (54%) have sequences that are assigned to YRNA and tRNA fragments respectively. Surprisingly, while many miRNAs can be detected, there are few miRNAs that are consistently detected in all samples from a single biofluid, and profiles of miRNA are different for each biofluid. Not unexpectedly, saliva samples have high levels of exogenous sequence that can be traced to bacteria. These data significantly contribute to the current number of sequenced exRNA samples from normal healthy individuals. PMID:28303895

  18. Uric acid is a main electron donor to peroxidases in human blood plasma.

    PubMed

    Padiglia, Alessandra; Medda, Rosaria; Longu, Silvia; Pedersen, Jens Z; Floris, Giovanni

    2002-11-01

    Peroxidases are widely distributed and have been isolated from many higher-order plants, animal tissues, yeast and microorganisms. During measurements of peroxidase activities in samples of human plasma, we noticed the presence of a compound in the plasma which was interfering with the peroxidase assay. In this paper we describe the purification and characterization of this factor, which was identified as uric acid. The procedure used to purify uric acid from plasma involved ultra-filtration of the plasma, heat denaturation, DEAE-cellulose chromatography, and high performance liquid chromatography. The lyophilized powder was tested for homogeneity using an HPLC apparatus and capillary electrophoresis. Genuine uric acid samples were used for comparison. The compound obtained by the above-reported purification procedure was identified as uric acid by spectrophotometric analysis through comparison with genuine uric acid samples. Spectrophotometric measurements indicated that uric acid was degraded by HRP in the presence of H2O2. The experimental procedures described above allowed us to isolate and identify uric acid as the component in human plasma that acts as a true substrate for peroxidases.

  19. Transversely Excited Atmospheric CO2 Laser-Induced Plasma Spectroscopy for the Detection of Heavy Metals in Soil

    NASA Astrophysics Data System (ADS)

    Khumaeni, A.; Sugito, H.; Setia Budi, W.; Yoyo Wardaya, A.

    2018-01-01

    A rapid detection of heavy metals in soil was presented by the metal-assisted gas plasma method using specific characteristics of a pulsed, transversely excited atmospheric (TEA) CO2 laser. The soil particles were placed in a hole made of acrylic plate. The sample was covered by a to prevent the soil particles from being blown off. The mesh also functioned to initiate a luminous plasma. When a TEA CO2 laser (1500 mJ, 200 ns) was focused on the soil sample, passing through the metal mesh, some of the laser energy was used to generate the gas plasma on the mesh surface, and the remaining laser energy was employed to ablate the soil particles. The fine, ablated soil particles moved into the gas plasma region to be dissociated and excited. Using this technique, analysis can be made with reduced sample pretreatment, and therefore a rapid analysis can be performed efficiently. The results proved that the signal to noise ratio (S/N) of the emission spectral lines is much better for the case of the present method (mesh method) compared to the case of standard laser-induced breakdown spectroscopy using the pellet method. Rapid detection of heavy metal elements in soil has been successfully carried out. The detection limits of Cu and Hg in soil were estimated to be 3 and 10 mg/kg, respectively. The present method has good potential for rapid and sensitive detection of heavy metals in soil samples.

  20. NASA GRC and MSFC Space-Plasma Arc Testing Procedures

    NASA Technical Reports Server (NTRS)

    Ferguson, Dale C.; Vayner, Boris V.; Galofaro, Joel T,; Hillard, G. Barry; Vaughn, Jason; Schneider, Todd

    2005-01-01

    Tests of arcing and current collection in simulated space plasma conditions have been performed at the NASA Glenn Research Center (GRC) in Cleveland, Ohio, for over 30 years and at the Marshall Space Flight Center (MSFC) in Huntsville, Alabama, for almost as long. During this period, proper test conditions for accurate and meaningful space simulation have been worked out, comparisons with actual space performance in spaceflight tests and with real operational satellites have been made, and NASA has achieved our own internal standards for test protocols. It is the purpose of this paper to communicate the test conditions, test procedures, and types of analysis used at NASA GRC and MSFC to the space environmental testing community at large, to help with international space-plasma arcing-testing standardization. To be discussed are: 1.Neutral pressures, neutral gases, and vacuum chamber sizes. 2. Electron and ion densities, plasma uniformity, sample sizes, and Debuy lengths. 3. Biasing samples versus self-generated voltages. Floating samples versus grounded. 4. Power supplies and current limits. Isolation of samples from power supplies during arcs. 5. Arc circuits. Capacitance during biased arc-threshold tests. Capacitance during sustained arcing and damage tests. Arc detection. Prevention sustained discharges during testing. 6. Real array or structure samples versus idealized samples. 7. Validity of LEO tests for GEO samples. 8. Extracting arc threshold information from arc rate versus voltage tests. 9. Snapover and current collection at positive sample bias. Glows at positive bias. Kapon (R) pyrolisis. 10. Trigger arc thresholds. Sustained arc thresholds. Paschen discharge during sustained arcing. 11. Testing for Paschen discharge threshold. Testing for dielectric breakdown thresholds. Testing for tether arcing. 12. Testing in very dense plasmas (ie thruster plumes). 13. Arc mitigation strategies. Charging mitigation strategies. Models. 14. Analysis of test results. Finally, the necessity of testing will be emphasized, not to the exclusion of modeling, but as part of a complete strategy for determining when and if arcs will occur, and preventing them from occurring in space.

  1. NASA GRC and MSFC Space-Plasma Arc Testing Procedures

    NASA Technical Reports Server (NTRS)

    Ferguson, Dale C.a; Vayner, Boris V.; Galofaro, Joel T.; Hillard, G. Barry; Vaughn, Jason; Schneider, Todd

    2005-01-01

    Tests of arcing and current collection in simulated space plasma conditions have been performed at the NASA Glenn Research Center (GRC) in Cleveland, Ohio, for over 30 years and at the Marshall Space flight Center (MSFC) for almost as long. During this period, proper test conditions for accurate and meaningful space simulation have been worked out, comparisons with actual space performance in spaceflight tests and with real operational satellites have been made, and NASA has achieved our own internal standards for test protocols. It is the purpose of this paper to communicate the test conditions, test procedures, and types of analysis used at NASA GRC and MSFC to the space environmental testing community at large, to help with international space-plasma arcing testing standardization. To be discussed are: 1. Neutral pressures, neutral gases, and vacuum chamber sizes. 2. Electron and ion densities, plasma uniformity, sample sizes, and Debye lengths. 3. Biasing samples versus self-generated voltages. Floating samples versus grounded. 4. Power supplies and current limits. Isolation of samples from power supplies during arcs. Arc circuits. Capacitance during biased arc-threshold tests. Capacitance during sustained arcing and damage tests. Arc detection. Preventing sustained discharges during testing. 5. Real array or structure samples versus idealized samples. 6. Validity of LEO tests for GEO samples. 7. Extracting arc threshold information from arc rate versus voltage tests. 8 . Snapover and current collection at positive sample bias. Glows at positive bias. Kapton pyrolization. 9. Trigger arc thresholds. Sustained arc thresholds. Paschen discharge during sustained arcing. 10. Testing for Paschen discharge thresholds. Testing for dielectric breakdown thresholds. Testing for tether arcing. 11. Testing in very dense plasmas (ie thruster plumes). 12. Arc mitigation strategies. Charging mitigation strategies. Models. 13. Analysis of test results. Finally, the necessity of testing will be emphasized, not to the exclusion of modeling, but as part of a complete strategy for determining when and if arcs will occur, and preventing them from occurring in space.

  2. Endothelial Inflammatory Transcriptional Responses Induced by Plasma Following Inhalation of Diesel Emissions

    PubMed Central

    Schisler, Jonathan C.; Ronnebaum, Sarah M.; Madden, Michael; Channell, Meghan M.; Campen, Matthew J.; Willis, Monte S.

    2016-01-01

    Background Air pollution, especially emissions derived from traffic sources, is associated with adverse cardiovascular outcomes. However, it remains unclear how inhaled factors drive extrapulmonary pathology. Objectives Previously, we found that canonical inflammatory response transcripts were elevated in cultured endothelial cells treated with plasma obtained after exposure compared with pre-exposure samples or filtered air (sham) exposures. While the findings confirmed the presence of bioactive factor(s) in the plasma after diesel inhalation, we wanted to better examine the complete genomic response to investigate 1) major responsive transcripts and 2) collected response pathways and ontogeny that may help to refine this method and inform the pathogenesis. Methods We assayed endothelial RNA with gene expression microarrays, examining the responses of cultured endothelial cells to plasma obtained from 6 healthy human subjects exposed to 100 μg/m3 diesel exhaust or filtered air for 2 h on separate occasions. In addition to pre-exposure baseline samples, we investigated samples obtained immediately-post and 24h-post exposure. Results Microarray analysis of the coronary artery endothelial cells challenged with plasma identified 855 probes that changed over time following diesel exhaust exposure. Over-representation analysis identified inflammatory cytokine pathways were upregulated both at the 2 and 24 h condition. Novel pathways related to FOX transcription factors and secreted extracellular factors were also identified in the microarray analysis. Conclusions These outcomes are consistent with our recent findings that plasma contains bioactive and inflammatory factors following pollutant inhalation. The specific study design implicates a novel pathway related to inflammatory blood borne components that may drive the extrapulmonary toxicity of ambient air pollutants. PMID:25942053

  3. Development of a rapid, simple assay of plasma total carotenoids

    PubMed Central

    2012-01-01

    Background Plasma total carotenoids can be used as an indicator of risk of chronic disease. Laboratory analysis of individual carotenoids by high performance liquid chromatography (HPLC) is time consuming, expensive, and not amenable to use beyond a research laboratory. The aim of this research is to establish a rapid, simple, and inexpensive spectrophotometric assay of plasma total carotenoids that has a very strong correlation with HPLC carotenoid profile analysis. Results Plasma total carotenoids from 29 volunteers ranged in concentration from 1.2 to 7.4 μM, as analyzed by HPLC. A linear correlation was found between the absorbance at 448 nm of an alcohol / heptane extract of the plasma and plasma total carotenoids analyzed by HPLC, with a Pearson correlation coefficient of 0.989. The average coefficient of variation for the spectrophotometric assay was 6.5% for the plasma samples. The limit of detection was about 0.3 μM and was linear up to about 34 μM without dilution. Correlations between the integrals of the absorption spectra in the range of carotenoid absorption and total plasma carotenoid concentration gave similar results to the absorbance correlation. Spectrophotometric assay results also agreed with the calculated expected absorbance based on published extinction coefficients for the individual carotenoids, with a Pearson correlation coefficient of 0.988. Conclusion The spectrophotometric assay of total carotenoids strongly correlated with HPLC analysis of carotenoids of the same plasma samples and expected absorbance values based on extinction coefficients. This rapid, simple, inexpensive assay, when coupled with the carotenoid health index, may be useful for nutrition intervention studies, population cohort studies, and public health interventions. PMID:23006902

  4. Metabolomic Quality Assessment of EDTA Plasma and Serum Samples.

    PubMed

    Malm, Linus; Tybring, Gunnel; Moritz, Thomas; Landin, Britta; Galli, Joakim

    2016-10-01

    Handling and processing of blood can significantly alter the molecular composition and consistency of biobank samples and can have a major impact on the identification of biomarkers. It is thus crucial to identify tools to determine the quality of samples to be used in biomarker discovery studies. In this study, a non-targeted gas chromatography/time-of-flight mass spectrometry (GC-TOFMS) metabolomic strategy was used with the aim of identifying quality markers for serum and plasma biobank collections lacking proper documentation of preanalytical handling. The effect of postcentrifugation delay was examined in serum stored in tubes with gel separation plugs and ethylenediaminetetraacetic acid (EDTA) plasma in tubes with or without gel separation plugs. The change in metabolic pattern was negligible in all sample types processed within 3 hours after centrifugation regardless of whether the samples were kept at 4°C or 22°C. After 8 and 24 hours postcentrifugation delay before aliquoting, there was a pronounced increase in the number of affected metabolites, as well as in the magnitude of the observed changes. No protective effect on the metabolites was observed in gel-separated EDTA plasma samples. In a separate series of experiments, lactate and glucose levels were determined in plasma to estimate the effect of precentrifugation delay. This separate experiment indicates that the lactate to glucose ratio may serve as a marker to identify samples with delayed time to centrifugation. Although our data from the untargeted GC-TOFMS analysis did not identify any specific markers, we conclude that plasma and serum metabolic profiles remain quite stable when plasma and serum are centrifuged and separated from the blood cells within 3 hours.

  5. Simultaneous determination of multiclass pesticide residues in human plasma using a mini QuEChERS method.

    PubMed

    Srivastava, Anshuman; Rai, Satyajeet; Kumar Sonker, Ashish; Karsauliya, Kajal; Pandey, Chandra Prabha; Singh, Sheelendra Pratap

    2017-06-01

    Blood is one of the most assessable matrices for the determination of pesticide residue exposure in humans. Effective sample preparation/cleanup of biological samples is very important in the development of a sensitive, reproducible, and robust method. In the present study, a simple, cost-effective, and rapid gas chromatography-tandem mass spectrometry method has been developed and validated for simultaneous analysis of 31 multiclass (organophosphates, organochlorines, and synthetic pyrethroids) pesticide residues in human plasma by means of a mini QuEChERS (quick, easy, cheap, effective, rugged, and safe) method. We have adopted a modified version of the QuEChERS method, which is primarily used for pesticide residue analysis in food commodities. The QuEChERS method was optimized by use of different extraction solvents and different amounts and combinations of salts and sorbents (primary-secondary amines and C 18 ) for the dispersive solid-phase extraction step. The results show that a combination of ethyl acetate with 2% acetic acid, magnesium sulfate (0.4 g), and solid-phase extraction for sample cleanup with primary-secondary amines (50 mg) per 1-mL volume of plasma is the most suitable for generating acceptable results with high recoveries for all multiclass pesticides from human plasma. The mean recovery ranged from 74% to 109% for all the analytes. The limit of quantification and limit of detection of the method ranged from 0.12 to 13.53 ng mL -1 and from 0.04 to 4.10 ng mL -1 respectively. The intraday precision and the interday precision of the method were 6% or less and 11% or less respectively. This method would be useful for the analysis of a wide range of pesticides of interest in a small volume of clinical and/or forensic samples to support biomonitoring and toxicological applications. Graphical Abstract Pesticide residues analysis in human plasma using mini QuEChERS method.

  6. Age-specific discrimination of blood plasma samples of healthy and ovarian cancer prone mice using laser-induced breakdown spectroscopy

    NASA Astrophysics Data System (ADS)

    Melikechi, Noureddine; Markushin, Yuri; Connolly, Denise C.; Lasue, Jeremie; Ewusi-Annan, Ebo; Makrogiannis, Sokratis

    2016-09-01

    Epithelial ovarian cancer (EOC) mortality rates are strongly correlated with the stage at which it is diagnosed. Detection of EOC prior to its dissemination from the site of origin is known to significantly improve the patient outcome. However, there are currently no effective methods for early detection of the most common and lethal subtype of EOC. We sought to determine whether laser-induced breakdown spectroscopy (LIBS) and classification techniques such as linear discriminant analysis (LDA) and random forest (RF) could classify and differentiate blood plasma specimens from transgenic mice with ovarian carcinoma and wild type control mice. Herein we report results using this approach to distinguish blood plasma samples obtained from serially bled (at 8, 12, and 16 weeks) tumor-bearing TgMISIIR-TAg transgenic and wild type cancer-free littermate control mice. We have calculated the age-specific accuracy of classification using 18,000 laser-induced breakdown spectra of the blood plasma samples from tumor-bearing mice and wild type controls. When the analysis is performed in the spectral range 250 nm to 680 nm using LDA, these are 76.7 (± 2.6)%, 71.2 (± 1.3)%, and 73.1 (± 1.4)%, for the 8, 12 and 16 weeks. When the RF classifier is used, we obtain values of 78.5 (± 2.3)%, 76.9 (± 2.1)% and 75.4 (± 2.0)% in the spectral range of 250 nm to 680 nm, and 81.0 (± 1.8)%, 80.4 (± 2.1)% and 79.6 (± 3.5)% in 220 nm to 850 nm. In addition, we report, the positive and negative predictive values of the classification of the two classes of blood plasma samples. The approach used in this study is rapid, requires only 5 μL of blood plasma, and is based on the use of unsupervised and widely accepted multivariate analysis algorithms. These findings suggest that LIBS and multivariate analysis may be a novel approach for detecting EOC.

  7. Determination of metoprolol enantiomers in human plasma and saliva samples utilizing microextraction by packed sorbent and liquid chromatography-tandem mass spectrometry.

    PubMed

    Elmongy, Hatem; Ahmed, Hytham; Wahbi, Abdel-Aziz; Amini, Ahmad; Colmsjö, Anders; Abdel-Rehim, Mohamed

    2016-08-01

    A sensitive, accurate and reliable bioanalytical method for the enantioselective determination of metoprolol in plasma and saliva samples utilizing liquid chromatography-electrospray ionization tandem mass spectrometry was developed and validated. Human plasma and saliva samples were pretreated by microextraction by packed sorbent (MEPS) prior to analysis. A new MEPS syringe form with two inputs was used. Metoprolol enantiomers and internal standard pentycaine (IS) were eluted from MEPS sorbent using isopropanol after removal of matrix interferences using aliquots of 5% methanol in water. Complete separation of metoprolol enantiomers was achieved on a Cellulose-SB column (150 × 4.6 mm, 5 μm) using isocratic elution with mobile phase 0.1% ammonium hydroxide in hexane-isopropanol (80:20, v/v) with a flow rate of 0.8 mL/min. A post-column solvent-assisted ionization was applied to enhance metoprolol ionization signal in positive mode monitoring (+ES) using 0.5% formic acid in isopropanol at a flow rate of 0.2 mL/min. The total chromatographic run time was 10 min for each injection. The detection of metoprolol in plasma and saliva samples was performed using triple quadrupole tandem mass spectrometer in +ES under the following mass transitions: m/z 268.08 → 72.09 for metoprolol and m/z 303.3 → 154.3 for IS. The linearity range was 2.5-500 ng/mL for both R- and S-metoprolol in plasma and saliva. The limits of detection and quantitation for both enantiomers were 0.5 and 2.5 ng/mL respectively, in both matrices (plasma and saliva). The intra- and inter-day precisions were presented in terms of RSD values for replicate analysis of quality control samples and were <5%; the accuracy of determinations varied from 96 to 99%. The method was able to determine the therapeutic levels of metoprolol enantiomers in both human plasma and saliva samples successfully, which can aid in therapeutic drug monitoring in clinical laboratories. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  8. Relationship Between Ebola Virus Real-Time Quantitative Polymerase Chain Reaction-Based Threshold Cycle Value and Virus Isolation From Human Plasma.

    PubMed

    Spengler, Jessica R; McElroy, Anita K; Harmon, Jessica R; Ströher, Ute; Nichol, Stuart T; Spiropoulou, Christina F

    2015-10-01

    We performed a longitudinal analysis of plasma samples obtained from 4 patients with Ebola virus (EBOV) disease (EVD) to determine the relationship between the real-time quantitative reverse transcriptase polymerase chain reaction (qRT-PCR)-based threshold cycle (Ct) value and the presence of infectious EBOV. EBOV was not isolated from plasma samples with a Ct value of >35.5 or >12 days after onset of symptoms. EBOV was not isolated from plasma samples in which anti-EBOV nucleoprotein immunoglobulin G was detected. These data demonstrate the utility of interpreting qRT-PCR results in the context of the course of EBOV infection and associated serological responses for patient-management decisions. Published by Oxford University Press on behalf of the Infectious Diseases Society of America 2015. This work is written by (a) US Government employee(s) and is in the public domain in the US.

  9. Analysis of ESR1 and PIK3CA mutations in plasma cell-free DNA from ER-positive breast cancer patients.

    PubMed

    Takeshita, Takashi; Yamamoto, Yutaka; Yamamoto-Ibusuki, Mutsuko; Tomiguchi, Mai; Sueta, Aiko; Murakami, Keiichi; Omoto, Yoko; Iwase, Hirotaka

    2017-08-08

    The measurement of ESR1 and PIK3CA mutations in plasma cell-free DNA (cfDNA) has been studied as a non-invasive method to quickly assess and monitor endocrine therapy (ET) resistant metastatic breast cancer (MBC) patients. The subjects of this retrospective study were a total of 185 plasma samples from 86 estrogen receptor-positive BC patients, of which 151 plasma samples were from 69 MBC patients and 34 plasma samples were from 17 primary BC (PBC) patients. We developed multiplex droplet digital PCR assays to verify the clinical significance of ESR1 and PIK3CA mutations both in a snapshot and serially in these patients. cfDNA ESR1 and PIK3CA mutations were found in 28.9% and 24.6 % of MBC patients, respectively. The relation between ESR1 or PIK3CA mutations and clinical features showed that ESR1 mutations occurred mostly in patients previously treated by ET, which was not the case for PIK3CA mutations. The analysis of the clinical impact of those mutations on subsequent lines of treatment for the 69 MBC patients revealed that both ESR1 and PIK3CA mutations detection were related to a shorter duration of ET effectiveness in univariate analysis but only for ESR1 mutations in multivariate analysis. The monitoring of cfDNA in a subset of 52 patients showed that loss of ESR1 mutations was related to a longer duration of response, which was not the case for PIK3CA mutations. We have demonstrated the clinical significance of on-treatment ESR1 mutations both in a snapshot and serially in comparison with PIK3CA mutations.

  10. Analysis of ESR1 and PIK3CA mutations in plasma cell-free DNA from ER-positive breast cancer patients

    PubMed Central

    Takeshita, Takashi; Yamamoto, Yutaka; Yamamoto-Ibusuki, Mutsuko; Tomiguchi, Mai; Sueta, Aiko; Murakami, Keiichi; Omoto, Yoko; Iwase, Hirotaka

    2017-01-01

    Background The measurement of ESR1 and PIK3CA mutations in plasma cell-free DNA (cfDNA) has been studied as a non-invasive method to quickly assess and monitor endocrine therapy (ET) resistant metastatic breast cancer (MBC) patients. Methods The subjects of this retrospective study were a total of 185 plasma samples from 86 estrogen receptor-positive BC patients, of which 151 plasma samples were from 69 MBC patients and 34 plasma samples were from 17 primary BC (PBC) patients. We developed multiplex droplet digital PCR assays to verify the clinical significance of ESR1 and PIK3CA mutations both in a snapshot and serially in these patients. Results cfDNA ESR1 and PIK3CA mutations were found in 28.9% and 24.6 % of MBC patients, respectively. The relation between ESR1 or PIK3CA mutations and clinical features showed that ESR1 mutations occurred mostly in patients previously treated by ET, which was not the case for PIK3CA mutations. The analysis of the clinical impact of those mutations on subsequent lines of treatment for the 69 MBC patients revealed that both ESR1 and PIK3CA mutations detection were related to a shorter duration of ET effectiveness in univariate analysis but only for ESR1 mutations in multivariate analysis. The monitoring of cfDNA in a subset of 52 patients showed that loss of ESR1 mutations was related to a longer duration of response, which was not the case for PIK3CA mutations. Conclusions We have demonstrated the clinical significance of on-treatment ESR1 mutations both in a snapshot and serially in comparison with PIK3CA mutations. PMID:28881720

  11. A comparative analysis of human plasma and serum proteins by combining native PAGE, whole-gel slicing and quantitative LC-MS/MS: Utilizing native MS-electropherograms in proteomic analysis for discovering structure and interaction-correlated differences.

    PubMed

    Wen, Meiling; Jin, Ya; Manabe, Takashi; Chen, Shumin; Tan, Wen

    2017-12-01

    MS identification has long been used for PAGE-separated protein bands, but global and systematic quantitation utilizing MS after PAGE has remained rare and not been reported for native PAGE. Here we reported on a new method combining native PAGE, whole-gel slicing and quantitative LC-MS/MS, aiming at comparative analysis on not only abundance, but also structures and interactions of proteins. A pair of human plasma and serum samples were used as test samples and separated on a native PAGE gel. Six lanes of each sample were cut, each lane was further sliced into thirty-five 1.1 mm × 1.1 mm squares and all the squares were subjected to standardized procedures of in-gel digestion and quantitative LC-MS/MS. The results comprised 958 data rows that each contained abundance values of a protein detected in one square in eleven gel lanes (one plasma lane excluded). The data were evaluated to have satisfactory reproducibility of assignment and quantitation. Totally 315 proteins were assigned, with each protein assigned in 1-28 squares. The abundance distributions in the plasma and serum gel lanes were reconstructed for each protein, named as "native MS-electropherograms". Comparison of the electropherograms revealed significant plasma-versus-serum differences on 33 proteins in 87 squares (fold difference > 2 or < 0.5, p < 0.05). Many of the differences matched with accumulated knowledge on protein interactions and proteolysis involved in blood coagulation, complement and wound healing processes. We expect this method would be useful to provide more comprehensive information in comparative proteomic analysis, on both quantities and structures/interactions. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  12. Liquid chromatography tandem mass spectrometry method for the quantitative analysis of ceritinib in human plasma and its application to pharmacokinetic studies.

    PubMed

    Heudi, Olivier; Vogel, Denise; Lau, Yvonne Y; Picard, Franck; Kretz, Olivier

    2014-11-01

    Ceritinib is a highly selective inhibitor of an important cancer target, anaplastic lymphoma kinase (ALK). Because it is an investigational compound, there is a need to develop a robust and reliable analytical method for its quantitative determination in human plasma. Here, we report the validation of a liquid chromatography tandem mass spectrometry (LC-MS/MS) method for the rapid quantification of ceritinib in human plasma. The method consists of protein precipitation with acetonitrile, and salting-out assisted liquid-liquid extraction (SALLE) using a saturated solution of sodium chloride prior to analysis by LC-MS/MS with electrospray ionization (ESI) technique in positive mode. Samples were eluted at 0.800 mL min(-1) on Ascentis Express® C18 column (50 mm × 2.1 mm, 2.7 μm) with a mobile phase made of 0.1 % formic acid in water (A) and 0.1 % formic acid in acetonitrile (B). The method run time was 3.6 min and the low limit of quantification (LLOQ) was estimated at 1.00 ng mL(-1) when using 0.100 mL of human plasma. The assay was fully validated and the method exhibited sufficient specificity, accuracy, precision, and sensitivity. In addition, recovery data and matrix factor (MF) in normal and in hemolyzed plasmas were assessed, while incurred samples stability (ISS) for ceritinib was demonstrated for at least 21 months at a storage temperature of -65 °C or below. The method was successfully applied to the measurement of ceritinib in clinical samples and the data obtained on incurred samples reanalysis (ISR) showed that our method was reliable and suitable to support the analysis of samples from the clinical studies.

  13. The effect of plasma pre-treatment on NaHCO3 desizing of blended sizes on cotton fabrics

    NASA Astrophysics Data System (ADS)

    Li, Xuming; Qiu, Yiping

    2012-03-01

    The influence of the He/O2 atmospheric pressure plasma jet pre-treatment on subsequent NaHCO3 desizing of blends of starch phosphate and poly(vinyl alcohol) on cotton fabrics is investigated. Atomic force microscopy and scanning electron microscopy analysis indicate that the surface topography of the samples has significantly changed and the surface roughness increases with an increase in plasma exposure time. X-ray photoelectron spectroscopy analysis shows that a larger number of oxygen-containing polar groups are formed on the sized fabric surface after the plasma treatment. The results of the percent desizing ratio (PDR) indicate that the plasma pretreatment facilitated the blended sizes removal from the cotton fabrics in subsequent NaHCO3 treatment and the PDR increases with prolonging plasma treatment time. The plasma technology is a promising pretreatment for desizing of blended sizes due to dramatically reduced desizing time.

  14. Determination of the rare-earth elements in geological materials by inductively coupled plasma mass spectrometry

    USGS Publications Warehouse

    Lichte, F.E.; Meier, A.L.; Crock, J.G.

    1987-01-01

    A method of analysis of geological materials for the determination of the rare-earth elements using the Inductively coupled plasma mass spectrometric technique (ICP-MS) has been developed. Instrumental parameters and factors affecting analytical results have been first studied and then optimized. Samples are analyzed directly following an acid digestion, without the need for separation or preconcentration with limits of detection of 2-11 ng/g, precision of ?? 2.5% relative standard deviation, and accuracy comparable to inductively coupled plasma emission spectrometry and instrumental neutron activation analysis. A commercially available ICP-MS instrument is used with modifications to the sample introduction system, torch, and sampler orifice to reduce the effects of high salt content of sample solutions prepared from geologic materials. Corrections for isobaric interferences from oxide ions and other diatomic and triatomic ions are made mathematically. Special internal standard procedures are used to compensate for drift in metahmetal oxide ratios and sensitivity. Reference standard values are used to verify the accuracy and utility of the method.

  15. The deuterium depth profile in neutron-irradiated tungsten exposed to plasma

    NASA Astrophysics Data System (ADS)

    Shimada, Masashi; Cao, G.; Hatano, Y.; Oda, T.; Oya, Y.; Hara, M.; Calderoni, P.

    2011-12-01

    Tungsten samples (99.99% purity from A.L.M.T. Corp., 6 mm in diameter, 0.2 mm in thickness) were irradiated by high-flux neutrons at 50 °C to 0.025 dpa in the High Flux Isotope Reactor at Oak Ridge National Laboratory. Subsequently, the neutron-irradiated tungsten samples were exposed to high-flux deuterium plasmas (ion flux: 1021-1022 m-2 s-1, ion fluence: 1025-1026 m-2) in the Tritium Plasma Experiment at Idaho National Laboratory. This paper reports the results of deuterium depth profiling in neutron-irradiated tungsten exposed to plasmas at 100, 200 and 500 °C via nuclear reaction analysis (NRA). The NRA measurements show that a significant amount of deuterium (>0.1 at.% D/W) remains trapped in the bulk material (up to 5 μm) at 500 °C. Tritium Migration Analysis Program simulation results using the NRA profiles indicate that different trapping mechanisms exist for neutron-irradiated and unirradiated tungsten.

  16. A simplified radiometabolite analysis procedure for PET radioligands using a solid phase extraction with micellar medium.

    PubMed

    Nakao, Ryuji; Halldin, Christer

    2013-07-01

    A solid phase extraction method has been developed for simple and high-speed direct determination of PET radioligands in plasma. This methodology makes use of a micellar medium and a solid-phase extraction cartridge for displacement of plasma protein bound radioligand and separation of PET radioligands from their radiometabolites without significant preparation. The plasma samples taken from monkey or human during PET measurements were mixed with a micellar eluent containing an anionic surfactant sodium dodecyl sulphate and loaded onto SPE cartridges. The amount of radioactivity corresponding to parent radioligand (retained on the cartridge) and its radioactive metabolites (eluted with micellar eluent) was measured. Under the optimized conditions, excellent separation of target PET radioligands from their radiometabolites was achieved with a single elution and short run-time of 1 min. This method was successfully applied to study the metabolism for (11)C-labelled radioligands in human or monkey plasma. The amount of parent PET radioligands estimated by micellar solid phase extraction strongly corresponded with that determined by radio-LC. The improved throughput permitted the analysis of a large number of plasma samples (up to 13 samples per one PET study) for accurate estimation of metabolite-corrected input function during quantitative PET imaging studies. Solid phase extraction together with micellar medium is fast, sensitive and easy to use, and therefore it is an attractive alternative method to determine relative composition of PET radioligands in plasma. Copyright © 2013 Elsevier Inc. All rights reserved.

  17. Method for Extraction and Multielement Analysis of Hypogymnia Physodes Samples from the Athabasca Oil Sands Region

    EPA Science Inventory

    A microwave-assisted digestion technique followed by ICPMS (inductively coupled plasma-mass spectrometry) analysis was used to measure concentrations of 43 elements in Hypogymnia physodes samples collected in the Athabasca Oil Sands Region (AOSR) of northern Alberta, Canad...

  18. Evaluation of Different Blood Collection Tubes and Blood Storage Conditions for the Preservation and Stability of Cell-Free Circulating DNA for the Analysis of the Methylated mSEPT9 Colorectal Cancer Screening Marker.

    PubMed

    Distler, Jurgen; Tetzner, Reimo; Weiss, Gunter; König, Thomas; Schlegel, Anne; Bagrowski, Michal

    2016-01-01

    For the subsequent analysis of the methylated mSEPT9 colorectal cancer screening marker in plasma, different blood collection tubes and blood storage conditions were investigated. The study demonstrated that methylated Septin 9 ( m SEPT9) can be consistently detected in plasma samples derived from whole blood samples collected with S-Monovette® K3E and BD Vacutainer ® K2EDTA tubes stored at 2-8 °C for a maximum of 24 h and for samples collected in S-Monovette CPDA tubes stored at 18-25 °C for up to 48 h.

  19. Methods of analysis by the U.S. Geological Survey National Water Quality Laboratory; use of a modified ultrasonic nebulizer for the analysis of low ionic-strength water by inductively coupled optical emission spectrometry

    USGS Publications Warehouse

    Harris, Carl M.; Litteral, Charles J.; Damrau, Donna L.

    1997-01-01

    The U.S. Geological Survey National Water Quality Laboratory has developed a method for the determination of dissolved calcium, iron, magnesium, manganese, silica, and sodium using a modified ultrasonic nebulizer sample-introduction system to an inductively coupled plasma-optical emission spectrometer. The nebulizer's spray chamber has been modified to avoid carryover and memory effects common in some conventional ultrasonic designs. The modified ultrasonic nebulizer is equipped with a high-speed rinse cycle to remove previously analyzed samples from the spray chamber without excessive flush times. This new rinse cycle decreases sample washout times by reducing carryover and memory effects from salt or analytes in previously analyzed samples by as much as 45 percent. Plasma instability has been reduced by repositioning the argon carrier gas inlet on the spray chamber and by directly pumping waste from the chamber, instead of from open drain traps, thereby maintaining constant pressure to the plasma. The ultrasonic nebulizer improves signal intensities, which are 8 to 16 times greater than for a conventional cross-flow pneumatic nebulizer, without being sensitive to clogging from salt buildup as in cross-flow nebulizers. Detection limits for the ultrasonic nebulizer are 4 to 18 times less than detection limits achievable using a cross-flow pneumatic nebulizer, with equivalent sample analysis time.

  20. New technique for the direct analysis of food powders confined in a small hole using transversely excited atmospheric CO(2) laser-induced gas plasma.

    PubMed

    Khumaeni, Ali; Ramli, Muliadi; Deguchi, Yoji; Lee, Yong Inn; Idris, Nasrullah; Kurniawan, Koo Hendrik; Lie, Tjung Jie; Kagawa, Kiichiro

    2008-12-01

    Taking advantage of the differences between the interactions of transversely excited atmospheric (TEA) CO(2) lasers with metal and with organic powder, a new technique for the direct analysis of food powder samples has been developed. In this technique, the powder samples were placed into a small hole with a diameter of 2 mm and a depth of 3 mm and covered by a metal mesh. The TEA CO(2) laser (1500 mJ, 200 ns) was focused on the powder sample surfaces, passing through the metal mesh, at atmospheric pressure in nitrogen gas. It is hypothesized that the small hole functions to confine the powder particles and suppresses the blowing-off of sample, while the metal mesh works as the source of electrons to initiate the strong gas breakdown plasma. The confined powder particles are then ablated by laser irradiation and the ablated particles move into the strong gas breakdown plasma region to be atomized and excited; this method cannot be applied for the case of Nd:YAG lasers because in such case the metal mesh itself was ablated by the laser irradiation. A quantitative analysis of a milk powder sample containing different concentrations of Ca was successfully demonstrated, resulting in a good linear calibration curve with high precision.

  1. Comparison of the quantification of acetaminophen in plasma, cerebrospinal fluid and dried blood spots using high-performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Taylor, Rachel R; Hoffman, Keith L; Schniedewind, Björn; Clavijo, Claudia; Galinkin, Jeffrey L; Christians, Uwe

    2013-09-01

    Acetaminophen (paracetamol, N-(4-hydroxyphenyl) acetamide) is one of the most commonly prescribed drugs for the management of pain in children. Quantification of acetaminophen in pre-term and term neonates and small children requires the availability of highly sensitive assays in small volume blood samples. We developed and validated an LC-MS/MS assay for the quantification of acetaminophen in human plasma, cerebro-spinal fluid (CSF) and dried blood spots (DBS). Reconstitution in water (DBS only) and addition of a protein precipitation solution containing the deuterated internal standard were the only manual steps. Extracted samples were analyzed on a Kinetex 2.6 μm PFP column using an acetonitrile/formic acid gradient. The analytes were detected in the positive multiple reaction mode. Alternatively, DBS were automatically processed using direct desorption in a sample card and preparation (SCAP) robotic autosampler in combination with online extraction. The range of reliable response in plasma and CSF was 3.05-20,000 ng/ml (r(2)>0.99) and 27.4-20,000 ng/ml (r(2)>0.99) for DBS (manual extraction and automated direct desorption). Inter-day accuracy was always within 85-115% and inter-day precision for plasma, CSF and manually extracted DBS were less than 15%. Deming regression analysis comparing 167 matching pairs of plasma and DBS samples showed a correlation coefficient of 0.98. Bland Altman analysis indicated a 26.6% positive bias in DBS, most likely reflecting the blood: plasma distribution ratio of acetaminophen. DBS are a valid matrix for acetaminophen pharmacokinetic studies. Copyright © 2013 Elsevier B.V. All rights reserved.

  2. Simultaneous analysis of retinol, all-trans- and 13-cis-retinoic acid and 13-cis-4-oxoretinoic acid in plasma by liquid chromatography using on-column concentration after single-phase fluid extraction.

    PubMed

    Teerlink, T; Copper, M P; Klaassen, I; Braakhuis, B J

    1997-06-20

    A reversed-phase high-performance liquid chromatographic method for the simultaneous analysis of retinol, all-trans-retinoic acid, 13-cis-retinoic acid and 13-cis-4-oxoretinoic acid in human plasma and cell culture medium is described. Sample preparation involves precipitation of proteins and extraction of retinoids with 60% acetonitrile. After centrifugation, the acetonitrile content of the supernatant is reduced to 45%, allowing on-column concentration of analytes. Injection volumes up to 2.0 ml (equivalent to 0.525 ml of sample) can be used without compromising chromatographic resolution of all-trans-retinoic acid and 13-cis-retinoic acid. Retinoids were stable in this extract and showed no isomerization when stored in the dark in a cooled autosampler, allowing automated analysis of large series of samples. Recoveries from spiked plasma samples were between 95 and 103%. Although no internal standard was used, the inter-assay precision for all retinoids was better than 6% and 4% at concentrations of 30 nM and 100 nM, respectively. The method is a valuable tool for the study of cellular metabolism of all-trans-retinoic acid, as polar metabolites of this compound can be detected with high sensitivity in cell culture media.

  3. Post-column infusion study of the 'dosing vehicle effect' in the liquid chromatography/tandem mass spectrometric analysis of discovery pharmacokinetic samples.

    PubMed

    Shou, Wilson Z; Naidong, Weng

    2003-01-01

    It has become increasingly popular in drug development to conduct discovery pharmacokinetic (PK) studies in order to evaluate important PK parameters of new chemical entities (NCEs) early in the discovery process. In these studies, dosing vehicles are typically employed in high concentrations to dissolve the test compounds in dose formulations. This can pose significant problems for the liquid chromatography/tandem mass spectrometric (LC/MS/MS) analysis of incurred samples due to potential signal suppression of the analytes caused by the vehicles. In this paper, model test compounds in rat plasma were analyzed using a generic fast gradient LC/MS/MS method. Commonly used dosing vehicles, including poly(ethylene glycol) 400 (PEG 400), polysorbate 80 (Tween 80), hydroxypropyl beta-cyclodextrin, and N,N-dimethylacetamide, were fortified into rat plasma at 5 mg/mL before extraction. Their effects on the sample analysis results were evaluated by the method of post-column infusion. Results thus obtained indicated that polymeric vehicles such as PEG 400 and Tween 80 caused significant suppression (> 50%, compared with results obtained from plasma samples free from vehicles) to certain analytes, when minimum sample cleanup was used and the analytes happened to co-elute with the vehicles. Effective means to minimize this 'dosing vehicle effect' included better chromatographic separations, better sample cleanup, and alternative ionization methods. Finally, a real-world example is given to illustrate the suppression problem posed by high levels of PEG 400 in sample analysis, and to discuss steps taken in overcoming the problem. A simple but effective means of identifying a 'dosing vehicle effect' is also proposed. Copyright 2003 John Wiley & Sons, Ltd.

  4. Evaluation of mechanism of cold atmospheric pressure plasma assisted polymerization of acrylic acid on low density polyethylene (LDPE) film surfaces: Influence of various gaseous plasma pretreatment

    NASA Astrophysics Data System (ADS)

    Ramkumar, M. C.; Pandiyaraj, K. Navaneetha; Arun Kumar, A.; Padmanabhan, P. V. A.; Uday Kumar, S.; Gopinath, P.; Bendavid, A.; Cools, P.; De Geyter, N.; Morent, R.; Deshmukh, R. R.

    2018-05-01

    Owing to its exceptional physiochemical properties, low density poly ethylene (LDPE) has wide range of tissue engineering applications. Conversely, its inadequate surface properties make LDPE an ineffectual candidate for cell compatible applications. Consequently, plasma-assisted polymerization with a selected precursor is a good choice for enhancing its biocompatibility. The present investigation studies the efficiency of plasma polymerization of acrylic acid (AAC) on various gaseous plasma pretreated LDPE films by cold atmospheric pressure plasma, to enhance its cytocompatibility. The change in chemical composition and surface topography of various gaseous plasma pretreated and acrylic deposited LDPE films has been assessed by X-ray photoelectron spectroscopy (XPS) and atomic force microscopy (AFM). The changes in hydrophilic nature of surface modified LDPE films were studied by contact angle (CA) analysis. Cytocompatibility of the AAC/LDPE films was also studied in vitro, using RIN-5F cells. The results acquired by the XPS and AFM analysis clearly proved that cold atmospheric pressure (CAP) plasma assisted polymerization of AAC enhances various surface properties including carboxylic acid functional group density and increased surface roughness on various gaseous plasma treated AAC/LDPE film surfaces. Moreover, contact angle analysis clearly showed that the plasma polymerized samples were hydrophilic in nature. In vitro cytocompatibility analysis undoubtedly validates that the AAC polymerized various plasma pretreated LDPE films surfaces stimulate cell distribution and proliferation compared to pristine LDPE films. Similarly, cytotoxicity analysis indicates that the AAC deposited various gaseous plasma pretreated LDPE film can be considered as non-toxic as well as stimulating cell viability significantly. The cytocompatible properties of AAC polymerized Ar + O2 plasma pretreated LDPE films were found to be more pronounced compared to the other plasma pretreated AAC/LDPE films.

  5. Optical spectroscopy of laser-produced plasmas for standoff isotopic analysis

    NASA Astrophysics Data System (ADS)

    Harilal, S. S.; Brumfield, B. E.; LaHaye, N. L.; Hartig, K. C.; Phillips, M. C.

    2018-06-01

    Rapid, in-field, and non-contact isotopic analysis of solid materials is extremely important to a large number of applications, such as nuclear nonproliferation monitoring and forensics, geochemistry, archaeology, and biochemistry. Presently, isotopic measurements for these and many other fields are performed in laboratory settings. Rapid, in-field, and non-contact isotopic analysis of solid material is possible with optical spectroscopy tools when combined with laser ablation. Laser ablation generates a transient vapor of any solid material when a powerful laser interacts with a sample of interest. Analysis of atoms, ions, and molecules in a laser-produced plasma using optical spectroscopy tools can provide isotopic information with the advantages of real-time analysis, standoff capability, and no sample preparation requirement. Both emission and absorption spectroscopy methods can be used for isotopic analysis of solid materials. However, applying optical spectroscopy to the measurement of isotope ratios from solid materials presents numerous challenges. Isotope shifts arise primarily due to variation in nuclear charge distribution caused by different numbers of neutrons, but the small proportional nuclear mass differences between nuclei of various isotopes lead to correspondingly small differences in optical transition wavelengths. Along with this, various line broadening mechanisms in laser-produced plasmas and instrumental broadening generated by the detection system are technical challenges frequently encountered with emission-based optical diagnostics. These challenges can be overcome by measuring the isotope shifts associated with the vibronic emission bands from molecules or by using the techniques of laser-based absorption/fluorescence spectroscopy to marginalize the effect of instrumental broadening. Absorption and fluorescence spectroscopy probe the ground state atoms existing in the plasma when it is cooler, which inherently provides narrower lineshapes, as opposed to emission spectroscopy which requires higher plasma temperatures to be able to detect thermally excited emission. Improvements in laser and detection systems and spectroscopic techniques have allowed for isotopic measurements to be carried out at standoff distances under ambient atmospheric conditions, which have expanded the applicability of optical spectroscopy-based isotopic measurements to a variety of scientific fields. These technological advances offer an in-situ measurement capability that was previously not available. This review will focus on isotope detection through emission, absorption, and fluorescence spectroscopy of atoms and molecules in a laser-produced plasma formed from a solid sample. A description of the physics behind isotope shifts in atoms and molecules is presented, followed by the physics behind solid sampling of laser ablation plumes, optical methods for isotope measurements, the suitable physical conditions of laser-produced plasma plumes for isotopic analysis, and the current status. Finally, concluding remarks will be made on the existing knowledge/technological gaps identified from the current literature and suggestions for the future work.

  6. Ultra-Sensitive Elemental Analysis Using Plasmas 5.Speciation of Arsenic Compounds in Biological Samples by High Performance Liquid Chromatography-Inductively Coupled Plasma Mass Spectrometry System

    NASA Astrophysics Data System (ADS)

    Kaise, Toshikazu

    Arsenic originating from the lithosphere is widely distributed in the environment. Many arsenicals in the environment are in organic and methylated species. These arsenic compounds in drinking water or food products of marine origin are absorbed in human digestive tracts, metabolized in the human body, and excreted viatheurine. Because arsenic shows varying biological a spects depending on its chemical species, the biological characteristics of arsenic must be determined. It is thought that some metabolic pathways for arsenic and some arsenic circulation exist in aqueous ecosystems. In this paper, the current status of the speciation analysis of arsenic by HPLC/ICP-MS (High Performance Liquid Chromatography-Inductively Coupled Plasma Mass spectrometry) in environmental and biological samples is summarized using recent data.

  7. Comprehensive solid-phase extraction of multitudinous bioactive peptides from equine plasma and urine for doping detection.

    PubMed

    Guan, Fuyu; Robinson, Mary A

    2017-09-08

    The ability to analyze biological samples for multitudinous exogenous peptides with a single analytical method is desired for doping control in horse racing. The key to achieving this goal is the capability of extracting all target peptides from the sample matrix. In the present study, theory of mixed-mode solid-phase extraction (SPE) of peptides from plasma is described, and a generic mixed-mode SPE procedure has been developed for recovering multitudinous exogenous peptides with remarkable sequence diversity, from equine plasma and urine in a single procedure. Both the theory and the developed SPE procedure have led to the development of a novel analytical method for comprehensive detection of multitudinous bioactive peptides in equine plasma and urine using liquid chromatography coupled to high resolution mass spectrometry (LC-HRMS). Thirty nine bioactive peptides were extracted with strong anion-exchange mixed-mode SPE sorbent, separated on a reversed-phase C 18 column and detected by HRMS and data-dependent tandem mass spectrometry. The limit of detection (LOD) was 10-50 pg mL -1 in plasma for most of the peptides and 100 pg mL -1 for the remaining. For urine, LOD was 20-400 pg mL -1 for most of the peptides and 1-4 ng mL -1 for the others. In vitro degradation of the peptides in equine plasma and urine was examined at ambient temperature; the peptides except those with a D-amino acid at position 2 were unstable not only in plasma but also in urine. The developed method was successful in analysis of plasma and urine samples from horses administered dermorphin. Additionally, dermorphin metabolites were identified in the absence of reference standards. The developed SPE procedure and LC-HRMS method can theoretically detect virtually all peptides present at a sufficient concentration in a sample. New peptides can be readily included in the method to be detected without method re-development. The developed method also generates such data that can be retrospectively analyzed for peptides unknown at the time of sample analysis. It is the first generic analytical method for comprehensive detection of multitudinous exogenous peptides in biological samples, to the authors' knowledge. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Shotgun Proteomic Analysis of Plasma from Dairy Cattle Suffering from Footrot: Characterization of Potential Disease-Associated Factors

    PubMed Central

    Sun, Dongbo; Zhang, Hong; Guo, Donghua; Sun, Anguo; Wang, Hongbin

    2013-01-01

    The plasma proteome of healthy dairy cattle and those with footrot was investigated using a shotgun LC-MS/MS approach. In total, 648 proteins were identified in healthy plasma samples, of which 234 were non-redundant proteins and 123 were high-confidence proteins; 712 proteins were identified from footrot plasma samples, of which 272 were non-redundant proteins and 138 were high-confidence proteins. The high-confidence proteins showed significant differences between healthy and footrot plasma samples in molecular weight, isoelectric points and the Gene Ontology categories. 22 proteins were found that may differentiate between the two sets of plasma proteins, of which 16 potential differential expression (PDE) proteins from footrot plasma involved in immunoglobulins, innate immune recognition molecules, acute phase proteins, regulatory proteins, and cell adhesion and cytoskeletal proteins; 6 PDE proteins from healthy plasma involved in regulatory proteins, cytoskeletal proteins and coagulation factors. Of these PDE proteins, haptoglobin, SERPINA10 protein, afamin precursor, haptoglobin precursor, apolipoprotein D, predicted peptidoglycan recognition protein L (PGRP-L) and keratan sulfate proteoglycan (KS-PG) were suggested to be potential footrot-associated factors. The PDE proteins PGRP-L and KS-PG were highlighted as potential biomarkers of footrot in cattle. The resulting protein lists and potential differentially expressed proteins may provide valuable information to increase understanding of plasma protein profiles in cattle and to assist studies of footrot-associated factors. PMID:23418487

  9. Lack of Association between Human Plasma Oxytocin and Interpersonal Trust in a Prisoner’s Dilemma Paradigm

    PubMed Central

    Christensen, James C.; Shiyanov, Pavel A.; Estepp, Justin R.; Schlager, John J.

    2014-01-01

    Expanding interest in oxytocin, particularly the role of endogenous oxytocin in human social behavior, has created a pressing need for replication of results and verification of assay methods. In this study, we sought to replicate and extend previous results correlating plasma oxytocin with trust and trustworthy behavior. As a necessary first step, the two most commonly used commercial assays were compared in human plasma via the addition of a known quantity of exogenous oxytocin, with and without sample extraction. Plasma sample extraction was found to be critical in obtaining repeatable concentrations of oxytocin. In the subsequent trust experiment, twelve samples in duplicate, from each of 82 participants, were collected over approximately six hours during the performance of a Prisoner’s Dilemma task paradigm that stressed human interpersonal trust. We found no significant relationship between plasma oxytocin concentrations and trusting or trustworthy behavior. In light of these findings, previous published work that used oxytocin immunoassays without sample extraction should be reexamined and future research exploring links between endogenous human oxytocin and trust or social behavior should proceed with careful consideration of methods and appropriate biofluids for analysis. PMID:25549255

  10. An Improved LC-ESI-MS/MS Method to Quantify Pregabalin in Human Plasma and Dry Plasma Spot for Therapeutic Monitoring and Pharmacokinetic Applications.

    PubMed

    Dwivedi, Jaya; Namdev, Kuldeep K; Chilkoti, Deepak C; Verma, Surajpal; Sharma, Swapnil

    2018-06-06

    Therapeutic drug monitoring (TDM) of anti-epileptic drugs provides a valid clinical tool in optimization of overall therapy. However, TDM is challenging due to the high biological samples (plasma/blood) storage/shipment costs and the limited availability of laboratories providing TDM services. Sampling in the form of dry plasma spot (DPS) or dry blood spot (DBS) is a suitable alternative to overcome these issues. An improved, simple, rapid, and stability indicating method for quantification of pregabalin in human plasma and DPS has been developed and validated. Analyses were performed on liquid chromatography tandem mass spectrometer under positive ionization mode of electrospray interface. Pregabain-d4 was used as internal standard, and the chromatographic separations were performed on Poroshell 120 EC-C18 column using an isocratic mobile phase flow rate of 1 mL/min. Stability of pregabalin in DPS was evaluated under simulated real-time conditions. Extraction procedures from plasma and DPS samples were compared using statistical tests. The method was validated considering the FDA method validation guideline. The method was linear over the concentration range of 20-16000 ng/mL and 100-10000 ng/mL in plasma and DPS, respectively. DPS samples were found stable for only one week upon storage at room temperature and for at least four weeks at freezing temperature (-20 ± 5 °C). Method was applied for quantification of pregabalin in over 600 samples of a clinical study. Statistical analyses revealed that two extraction procedures in plasma and DPS samples showed statistically insignificant difference and can be used interchangeably without any bias. Proposed method involves simple and rapid steps of sample processing that do not require a pre- or post-column derivatization procedure. The method is suitable for routine pharmacokinetic analysis and therapeutic monitoring of pregabalin.

  11. The Influence of Plasma-Based Nitriding and Oxidizing Treatments on the Mechanical and Corrosion Properties of CoCrMo Biomedical Alloy

    NASA Astrophysics Data System (ADS)

    Noli, Fotini; Pichon, Luc; Öztürk, Orhan

    2018-04-01

    Plasma-based nitriding and/or oxidizing treatments were applied to CoCrMo alloy to improve its surface mechanical properties and corrosion resistance for biomedical applications. Three treatments were performed. A set of CoCrMo samples has been subjected to nitriding at moderate temperatures ( 400 °C). A second set of CoCrMo samples was oxidized at 395 °C in pure O2. The last set of CoCrMo samples was nitrided and subsequently oxidized under the experimental conditions of previous sets (double treatment). The microstructure and morphology of the layers formed on the CoCrMo alloy were investigated by X-ray diffraction, Atomic Force Microscopy, and Scanning Electron Microscopy. In addition, nitrogen and oxygen profiles were determined by Glow Discharge Optical Emission Spectroscopy, Rutherford Backscattering Spectroscopy, Energy-Dispersive X-ray, and Nuclear Reaction Analysis. Significant improvement of the Vickers hardness of the CoCrMo samples after plasma nitriding was observed due to the supersaturated nitrogen solution and the formation of an expanded FCC γ N phase and CrN precipitates. In the case of the oxidized samples, Vickers hardness improvement was minimal. The corrosion behavior of the samples was investigated in simulated body fluid (0.9 pct NaCl solution at 37 °C) using electrochemical techniques (potentiodynamic polarization and cyclic voltammetry). The concentration of metal ions released from the CoCrMo surfaces was determined by Instrumental Neutron Activation Analysis. The experimental results clearly indicate that the CoCrMo surface subjected to the double surface treatment consisting in plasma nitriding and plasma oxidizing exhibited lower deterioration and better resistance to corrosion compared to the nitrided, oxidized, and untreated samples. This enhancement is believed to be due to the formation of a thicker and more stable layer.

  12. System of Mueller-Jones matrix polarizing mapping of blood plasma films in breast pathology

    NASA Astrophysics Data System (ADS)

    Zabolotna, Natalia I.; Radchenko, Kostiantyn O.; Tarnovskiy, Mykola H.

    2017-08-01

    The combined method of Jones-Mueller matrix mapping and blood plasma films analysis based on the system that proposed in this paper. Based on the obtained data about the structure and state of blood plasma samples the diagnostic conclusions can be make about the state of breast cancer patients ("normal" or "pathology"). Then, by using the statistical analysis obtain statistical and correlational moments for every coordinate distributions; these indicators are served as diagnostic criterias. The final step is to comparing results and choosing the most effective diagnostic indicators. The paper presents the results of Mueller-Jones matrix mapping of optically thin (attenuation coefficient ,τ≤0,1) blood plasma layers.

  13. Development and validation of amitriptyline and its metabolite in human plasma by ultra performance liquid chromatography-tandem mass spectrometry and its application to a bioequivalence study.

    PubMed

    Bhatt, Mitesh; Shah, Sanjay

    2010-11-01

    A method based on ultra performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) in combination with solid-phase extraction for sample pretreatment has been developed for the simultaneous analysis of amitriptyline and its main metabolite in human plasma. The extraction of the analytes from plasma samples was carried out by means of a selective SPE procedure using hydrophilic-lipophilic balance cartridges. The assay involves a simple solid-phase extraction (SPE) procedure of 0.2 mL of human plasma and analysis was performed on a triple-quadrupole tandem mass spectrometer by multiple reactions monitoring (MRM) mode via electrospray ionization (ESI). The standard calibration curve was linear over the ranges 0.370-95.539 ng/mL for amitriptyline and 0.365-94.374 ng/mL for nortriptyline, expressed by the linear correlation coefficient r², which was better than 0.995 for both. The intra- and inter-day precision and accuracy of the quality control samples were within 10.0%. The recovery was 85.3, 88.4 and 80.7% for amitriptyline, nortriptyline and doxepin respectively. Total run time was 1.2 min only for each sample, which makes it possible to analyze more than 400 samples per day. The method was highly reproducible and gave peaks with excellent chromatography properties. Copyright © 2010 John Wiley & Sons, Ltd.

  14. Clinical Validation of Therapeutic Drug Monitoring of Imipenem in Spent Effluent in Critically Ill Patients Receiving Continuous Renal Replacement Therapy: A Pilot Study

    PubMed Central

    Wen, Aiping; Li, Zhe; Yu, Junxian; Li, Ren; Cheng, Sheng; Duan, Meili; Bai, Jing

    2016-01-01

    Objectives The primary objective of this pilot study was to investigate whether the therapeutic drug monitoring of imipenem could be performed with spent effluent instead of blood sampling collected from critically ill patients under continuous renal replacement therapy. Methods A prospective open-label study was conducted in a real clinical setting. Both blood and effluent samples were collected pairwise before imipenem administration and 0.5, 1, 1.5, 2, 3, 4, 6, and 8 h after imipenem administration. Plasma and effluent imipenem concentrations were determined by reversed-phase high-performance liquid chromatography with ultraviolet detection. Pharmacokinetic and pharmacodynamic parameters of blood and effluent samples were calculated. Results Eighty-three paired plasma and effluent samples were obtained from 10 patients. The Pearson correlation coefficient of the imipenem concentrations in plasma and effluent was 0.950 (P<0.0001). The average plasma-to-effluent imipenem concentration ratio was 1.044 (95% confidence interval, 0.975 to 1.114) with Bland-Altman analysis. No statistically significant difference was found in the pharmacokinetic and pharmacodynamic parameters tested in paired plasma and effluent samples with Wilcoxon test. Conclusion Spent effluent of continuous renal replacement therapy could be used for therapeutic drug monitoring of imipenem instead of blood sampling in critically ill patients. PMID:27093294

  15. Comparative study between chemical and atmospheric pressure plasma jet cleaning on glass substrate

    NASA Astrophysics Data System (ADS)

    Elfa, Rizan Rizon; Ahmad, Mohd Khairul; Fhong, Soon Chin; Sahdan, Mohd Zainizan; Nayan, Nafarizal

    2017-01-01

    The atmospheric pressure plasma jet with low frequency and argon as working gas is presented in this paper to demonstrate its application for glass substrate clean and modification. The glass substrate clean by atmospheric pressure plasma jet is an efficient method to replace other substrate clean method. A comparative analysis is done in this paper between substrate cleaned by chemical and plasma treatment methods. Water contact angle reading is taken for a different method of substrate clean and period of treatment. Under the plasma treatment, the sample shows low surface adhesion due to having the surface property of super hydrophilic surface 7.26°. This comparative analysis is necessary in the industrial application for cost production due to sufficient time and method of substrate clean.

  16. Plasma circulating tumor DNA as an alternative to metastatic biopsies for mutational analysis in breast cancer.

    PubMed

    Rothé, F; Laes, J-F; Lambrechts, D; Smeets, D; Vincent, D; Maetens, M; Fumagalli, D; Michiels, S; Drisis, S; Moerman, C; Detiffe, J-P; Larsimont, D; Awada, A; Piccart, M; Sotiriou, C; Ignatiadis, M

    2014-10-01

    Molecular screening programs use next-generation sequencing (NGS) of cancer gene panels to analyze metastatic biopsies. We interrogated whether plasma could be used as an alternative to metastatic biopsies. The Ion AmpliSeq™ Cancer Hotspot Panel v2 (Ion Torrent), covering 2800 COSMIC mutations from 50 cancer genes was used to analyze 69 tumor (primary/metastases) and 31 plasma samples from 17 metastatic breast cancer patients. The targeted coverage for tumor DNA was ×1000 and for plasma cell-free DNA ×25 000. Whole blood normal DNA was used to exclude germline variants. The Illumina technology was used to confirm observed mutations. Evaluable NGS results were obtained for 60 tumor and 31 plasma samples from 17 patients. When tumor samples were analyzed, 12 of 17 (71%, 95% confidence interval (CI) 44% to 90%) patients had ≥1 mutation (median 1 mutation per patient, range 0-2 mutations) in either p53, PIK3CA, PTEN, AKT1 or IDH2 gene. When plasma samples were analyzed, 12 of 17 (71%, 95% CI: 44-90%) patients had ≥1 mutation (median 1 mutation per patient, range 0-2 mutations) in either p53, PIK3CA, PTEN, AKT1, IDH2 and SMAD4. All mutations were confirmed. When we focused on tumor and plasma samples collected at the same time-point, we observed that, in four patients, no mutation was identified in either tumor or plasma; in nine patients, the same mutations was identified in tumor and plasma; in two patients, a mutation was identified in tumor but not in plasma; in two patients, a mutation was identified in plasma but not in tumor. Thus, in 13 of 17 (76%, 95% CI 50% to 93%) patients, tumor and plasma provided concordant results whereas in 4 of 17 (24%, 95% CI 7% to 50%) patients, the results were discordant, providing complementary information. Plasma can be prospectively tested as an alternative to metastatic biopsies in molecular screening programs. © The Author 2014. Published by Oxford University Press on behalf of the European Society for Medical Oncology. All rights reserved. For permissions, please email: journals.permissions@oup.com.

  17. Plasma protein absolute quantification by nano-LC Q-TOF UDMSE for clinical biomarker verification

    PubMed Central

    ILIES, MARIA; IUGA, CRISTINA ADELA; LOGHIN, FELICIA; DHOPLE, VISHNU MUKUND; HAMMER, ELKE

    2017-01-01

    Background and aims Proteome-based biomarker studies are targeting proteins that could serve as diagnostic, prognosis, and prediction molecules. In the clinical routine, immunoassays are currently used for the absolute quantification of such biomarkers, with the major limitation that only one molecule can be targeted per assay. The aim of our study was to test a mass spectrometry based absolute quantification method for the verification of plasma protein sets which might serve as reliable biomarker panels for the clinical practice. Methods Six EDTA plasma samples were analyzed after tryptic digestion using a high throughput data independent acquisition nano-LC Q-TOF UDMSE proteomics approach. Synthetic Escherichia coli standard peptides were spiked in each sample for the absolute quantification. Data analysis was performed using ProgenesisQI v2.0 software (Waters Corporation). Results Our method ensured absolute quantification of 242 non redundant plasma proteins in a single run analysis. The dynamic range covered was 105. 86% were represented by classical plasma proteins. The overall median coefficient of variation was 0.36, while a set of 63 proteins was found to be highly stable. Absolute protein concentrations strongly correlated with values reviewed in the literature. Conclusions Nano-LC Q-TOF UDMSE proteomic analysis can be used for a simple and rapid determination of absolute amounts of plasma proteins. A large number of plasma proteins could be analyzed, while a wide dynamic range was covered with low coefficient of variation at protein level. The method proved to be a reliable tool for the quantification of protein panel for biomarker verification in the clinical practice. PMID:29151793

  18. Effect of acute dietary standardization on the urinary, plasma, and salivary metabolomic profiles of healthy humans.

    PubMed

    Walsh, Marianne C; Brennan, Lorraine; Malthouse, J Paul G; Roche, Helen M; Gibney, Michael J

    2006-09-01

    Metabolomics in human nutrition research is faced with the challenge that changes in metabolic profiles resulting from diet may be difficult to differentiate from normal physiologic variation. We assessed the extent of intra- and interindividual variation in normal human metabolic profiles and investigated the effect of standardizing diet on reducing variation. Urine, plasma, and saliva were collected from 30 healthy volunteers (23 females, 7 males) on 4 separate mornings. For visits 1 and 2, free food choice was permitted on the day before biofluid collection. Food choice on the day before visit 3 was intended to mimic that for visit 2, and all foods were standardized on the day before visit 4. Samples were analyzed by using 1H nuclear magnetic resonance spectroscopy followed by multivariate data analysis. Intra- and interindividual variations were considerable for each biofluid. Visual inspection of the principal components analysis scores plots indicated a reduction in interindividual variation in urine, but not in plasma or saliva, after the standard diet. Partial least-squares discriminant analysis indicated time-dependent changes in urinary and salivary samples, mainly resulting from creatinine in urine and acetate in saliva. The predictive power of each model to classify the samples as either night or morning was 85% for urine and 75% for saliva. Urine represented a sensitive metabolic profile that reflected acute dietary intake, whereas plasma and saliva did not. Future metabolomics studies should consider recent dietary intake and time of sample collection as a means of reducing normal physiologic variation.

  19. Minimally-invasive Laser Ablation Inductively Coupled Plasma Mass Spectrometry analysis of model ancient copper alloys

    NASA Astrophysics Data System (ADS)

    Walaszek, Damian; Senn, Marianne; Wichser, Adrian; Faller, Markus; Wagner, Barbara; Bulska, Ewa; Ulrich, Andrea

    2014-09-01

    This work describes an evaluation of a strategy for multi-elemental analysis of typical ancient bronzes (copper, lead bronze and tin bronze) by means of laser ablation inductively coupled plasma mass spectrometry (LA-ICPMS).The samples originating from archeological experiments on ancient metal smelting processes using direct reduction in a ‘bloomery’ furnace as well as historical casting techniques were investigated with the use of the previously proposed analytical procedure, including metallurgical observation and preliminary visual estimation of the homogeneity of the samples. The results of LA-ICPMS analysis were compared to the results of bulk composition obtained by X-ray fluorescence spectrometry (XRF) and by inductively coupled plasma mass spectrometry (ICPMS) after acid digestion. These results were coherent for most of the elements confirming the usefulness of the proposed analytical procedure, however the reliability of the quantitative information about the content of the most heterogeneously distributed elements was also discussed in more detail.

  20. High wavenumber Raman spectroscopic characterization of normal and oral cancer using blood plasma

    NASA Astrophysics Data System (ADS)

    Pachaiappan, Rekha; Prakasarao, Aruna; Suresh Kumar, Murugesan; Singaravelu, Ganesan

    2017-02-01

    Blood plasma possesses the biomolecules released from cells/tissues after metabolism and reflects the pathological conditions of the subjects. The analysis of biofluids for disease diagnosis becomes very attractive in the diagnosis of cancers due to the ease in the collection of samples, easy to transport, multiple sampling for regular screening of the disease and being less invasive to the patients. Hence, the intention of this study was to apply near-infrared (NIR) Raman spectroscopy in the high wavenumber (HW) region (2500-3400 cm-1) for the diagnosis of oral malignancy using blood plasma. From the Raman spectra it is observed that the biomolecules protein and lipid played a major role in the discrimination between groups. The diagnostic algorithms based on principal components analysis coupled with linear discriminant analysis (PCA-LDA) with the leave-one-patient-out cross-validation method on HW Raman spectra yielded a promising results in the identification of oral malignancy. The details of results will be discussed.

  1. Comparison between dried blood spot and plasma sampling for therapeutic drug monitoring of antiepileptic drugs in children with epilepsy: A step towards home sampling.

    PubMed

    Linder, Camilla; Wide, Katarina; Walander, Malin; Beck, Olof; Gustafsson, Lars L; Pohanka, Anton

    2017-05-01

    To investigate if dried blood spots could be used for therapeutic drug monitoring of the antiepileptic drugs, carbamazepine, lamotrigine and valproic acid in children with epilepsy. Fingerprick blood samples from 46 children at a neuropediatric outpatient clinic was collected on filterpaper at the same time as capillary plasma sampling. A validated dried blood spot liquid chromatography tandem mass spectrometry method for carbamazepine, lamotrigine and valproic acid was compared with the routine plasma laboratory methods. Method agreement was evaluated and plasma concentrations were estimated by different conversion approaches. Strong correlation was shown between dried blood spot and plasma concentrations for all three drugs, with R2 values>0.89. Regression analysis showed a proportional bias with 35% lower dried blood spot concentrations for valproic acid (n=33) and concentrations were 18% higher for carbamazepine (n=17). A ratio approach was used to make a conversion from dried blood spots to estimated plasma for these two drugs. Dried blood spot concentrations were directly comparable with plasma for lamotrigine (n=20). This study supports that dried blood spot concentrations can be used as an alternative to plasma in a children population for three commonly used antiepileptic drugs with the possibility to expand by adding other antiepileptic drugs. Clinical decisions can be made based on converted (carbamazepine, valproic acid) or unconverted (lamotrigine) dried blood spot concentrations. Dried blood spot sampling, in the future taken at home, will simplify an effective therapeutic drug monitoring for this group of patients who often have concomitant disorders and also reduce costs for society. Copyright © 2016 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  2. Multi-elemental analysis of aqueous geological samples by inductively coupled plasma-optical emission spectrometry

    USGS Publications Warehouse

    Todorov, Todor I.; Wolf, Ruth E.; Adams, Monique

    2014-01-01

    Typically, 27 major, minor, and trace elements are determined in natural waters, acid mine drainage, extraction fluids, and leachates of geological and environmental samples by inductively coupled plasma-optical emission spectrometry (ICP-OES). At the discretion of the analyst, additional elements may be determined after suitable method modifications and performance data are established. Samples are preserved in 1–2 percent nitric acid (HNO3) at sample collection or as soon as possible after collection. The aqueous samples are aspirated into the ICP-OES discharge, where the elemental emission signals are measured simultaneously for 27 elements. Calibration is performed with a series of matrix-matched, multi-element solution standards.

  3. Shock wave plasma induced emission generated by low energy nanosecond Nd:YAG laser in open air and its application to quantitative Cr analysis of low alloy steel

    NASA Astrophysics Data System (ADS)

    Idris, Nasrullah; Pardede, Marincan; Kurniawan, Koo Hendrik; Kagawa, Kiichiro; Tjia, May On

    2018-05-01

    We report the result of an experimental study that shows the remarkable benefits of generating a micro shock wave plasma by low energy (800 μJ) nanosecond (ns) Nd:YAG laser irradiation on a solid target in open air and the efficient detection of the induced plasma emission. The very low irradiation power density of 0.8 MW/cm2 produced by the slightly defocused laser beam gives the additional advantage of rather wide crater size of 400 μm on the sample surface, thus enabling average analysis and reducing the ion production responsible for the undesirable emission background as well as the Stark broadening effect, and thus leading to largely improved spectral quality. This is corroborated by the result of spectra measured from a number of metal samples which display the sharp emission lines with low background. Specifically, its application to Cr analysis of a series of low alloy steel samples with different Cr concentrations is shown to yield a linear calibration line of adequate dynamical range and an estimated detection limit of about 10 ppm.

  4. High-throughput SISCAPA quantitation of peptides from human plasma digests by ultrafast, liquid chromatography-free mass spectrometry.

    PubMed

    Razavi, Morteza; Frick, Lauren E; LaMarr, William A; Pope, Matthew E; Miller, Christine A; Anderson, N Leigh; Pearson, Terry W

    2012-12-07

    We investigated the utility of an SPE-MS/MS platform in combination with a modified SISCAPA workflow for chromatography-free MRM analysis of proteotypic peptides in digested human plasma. This combination of SISCAPA and SPE-MS/MS technology allows sensitive, MRM-based quantification of peptides from plasma digests with a sample cycle time of ∼7 s, a 300-fold improvement over typical MRM analyses with analysis times of 30-40 min that use liquid chromatography upstream of MS. The optimized system includes capture and enrichment to near purity of target proteotypic peptides using rigorously selected, high affinity, antipeptide monoclonal antibodies and reduction of background peptides using a novel treatment of magnetic bead immunoadsorbents. Using this method, we have successfully quantitated LPS-binding protein and mesothelin (concentrations of ∼5000 ng/mL and ∼10 ng/mL, respectively) in human plasma. The method eliminates the need for upstream liquid-chromatography and can be multiplexed, thus facilitating quantitative analysis of proteins, including biomarkers, in large sample sets. The method is ideal for high-throughput biomarker validation after affinity enrichment and has the potential for applications in clinical laboratories.

  5. Effect of solvent/detergent-treated pooled plasma on fibrinolysis in reconstituted whole blood.

    PubMed

    Saadah, Nicholas H; van der Meer, Pieter F; Brinkman, Herm Jan M; de Korte, Dirk; Bontekoe, Ido J; Korsten, Herbert H; Middelburg, Rutger A; van der Bom, Johanna G; Schipperus, Martin R

    2017-10-01

    Hyperfibrinolysis has been observed in patients heavily transfused with solvent/detergent-treated pooled plasma (S/D plasma). We compared coagulation and fibrinolytic variables in blood containing S/D plasma with blood containing fresh-frozen plasma (FFP), with and without α2-antiplasmin or tranexamic acid (TXA) supplementation. Whole blood samples were reconstituted from red blood cells, platelet (PLT) concentrates, and varying mixtures of FFP and S/D plasma. Hematocrit and PLT count of reconstituted whole blood samples were varied. For a subset of runs, α2-antiplasmin or TXA was added to S/D plasma whole blood samples. Thromboelastography (TEG) analysis was performed to assess 50% clot lysis time (CLT 50% ), maximum amplitude (MA), and initial clotting time (R-time). The change in CLT 50% of whole blood as the plasma compartment transitions from FFP to S/D plasma was -52% (95% confidence interval [CI], -60% to -45%; p < 0.001). PLT count strengthened the effect, leading to an additional change in CLT 50% of -8% (95% CI, -14% to -2%; p = 0.012) as PLT count increased from 10 × 10 9 to 150 × 10 9 /L. MA and R-time were not associated with fraction of S/D plasma in whole blood. α2-Antiplasmin and TXA restored clot lysis time in S/D plasma whole blood. Whole blood with S/D plasma has shorter clot lysis times in vitro compared to whole blood with FFP. α2-Antiplasmin and TXA restore clot lysis time of S/D plasma whole blood to that of FFP whole blood. Clinicians should be aware of the decreased clot lysis time associated with S/D plasma transfusion. © 2017 AABB.

  6. Trace elemental composition of curry by inductively coupled plasma optical emission spectrometry (ICP-OES).

    PubMed

    Gonzálvez, A; Armenta, S; De La Guardia, M

    2008-01-01

    A methodology based on inductively coupled plasma optical emission spectrometry (ICP-OES) after microwave-assisted acid digestion was developed to determine the content of traces elements in curry samples from the Spanish market. The methodology was validated in terms of accuracy by the analysis of citrus and tomato leaf reference materials achieving comparable results with the certified values. The trace metal content of curry samples was compared with data available from previously published reports concerning Indian samples, especially in terms of heavy metal composition, in order to guarantee the quality of the commercially available spices in the European countries. Values found for the analysis of arsenic, lead and cadmium were significantly lower than the maximum limit allowed by European Union statutory limits for heavy metals and lower than those obtained for Indian curry leaves reported by Indian research teams by using neutron activation and γ-ray analysis.

  7. Use of laser ablation-inductively coupled plasma-time of flight-mass spectrometry to identify the elemental composition of vanilla and determine the geographic origin by discriminant function analysis.

    PubMed

    Hondrogiannis, Ellen M; Ehrlinger, Erin; Poplaski, Alyssa; Lisle, Meredith

    2013-11-27

    A total of 11 elements found in 25 vanilla samples from Uganda, Madagascar, Indonesia, and Papua New Guinea were measured by laser ablation-inductively coupled plasma-time-of-flight-mass spectrometry (LA-ICP-TOF-MS) for the purpose of collecting data that could be used to discriminate among the origins. Pellets were prepared of the samples, and elemental concentrations were obtained on the basis of external calibration curves created using five National Institute of Standards and Technology (NIST) standards and one Chinese standard with (13)C internal standardization. These curves were validated using NIST 1573a (tomato leaves) as a check standard. Discriminant analysis was used to successfully classify the vanilla samples by their origin. Our method illustrates the feasibility of using LA-ICP-TOF-MS with an external calibration curve for high-throughput screening of spice screening analysis.

  8. Dried blood spot HIV-1 RNA quantification: A useful tool for viral load monitoring among HIV-infected individuals in India

    PubMed Central

    Neogi, Ujjwal; Gupta, Soham; Rodridges, Rashmi; Sahoo, Pravat Nalini; Rao, Shwetha D.; Rewari, Bharat B.; Shastri, Suresh; De Costa, Ayesha; Shet, Anita

    2012-01-01

    Background & objectives: Monitoring of HIV-infected individuals on antiretroviral treatment (ART) ideally requires periodic viral load measurements to ascertain adequate response to treatment. While plasma viral load monitoring is widely available in high-income settings, it is rarely used in resource-limited regions because of high cost and need for sophisticated sample transport. Dried blood spot (DBS) as source specimens for viral load measurement has shown promise as an alternative to plasma specimens and is likely to be a useful tool for Indian settings. The present study was undertaken to investigate the performance of DBS in HIV-1 RNA quantification against the standard plasma viral load assay. Methods: Between April-June 2011, 130 samples were collected from HIV-1-infected (n=125) and non-infected (n=5) individuals in two district clinics in southern India. HIV-1 RNA quantification was performed from DBS and plasma using Abbott m2000rt system after manual RNA extraction. Statistical analysis included correlation, regression and Bland-Altman analysis. Results: The sensitivity of DBS viral load was 97 per cent with viral loads >3.0 log10 copies/ml. Measurable viral load (>3.0 log 10 copies/ml) results obtained for the 74 paired plasma-DBS samples showed positive correlation between both the assays (r=0.96). For clinically acceptable viral load threshold values of >5,000 copies/ml, Bland-Altman plots showed acceptable limits of agreement (−0.21 to +0.8 log10 copies/ml). The mean difference was 0.29 log10 copies/ml. The cost of DBS was $2.67 lower compared to conventional plasma viral load measurement in the setting Interpretation & conclusions: The significant positive correlation with standard plasma-based assay and lower cost of DBS viral load monitoring suggest that DBS sampling can be a feasible and economical means of viral load monitoring in HIV-infected individual in India and in other resource-limited settings globally. PMID:23391790

  9. Analysis of GaN Damage Induced by Cl2/SiCl4/Ar Plasma

    NASA Astrophysics Data System (ADS)

    Minami, Masaki; Tomiya, Shigetaka; Ishikawa, Kenji; Matsumoto, Ryosuke; Chen, Shang; Fukasawa, Masanaga; Uesawa, Fumikatsu; Sekine, Makoto; Hori, Masaru; Tatsumi, Tetsuya

    2011-08-01

    GaN-based optical devices are fabricated using a GaN/InGaN/GaN sandwiched structure. The effect of radicals, ions, and UV light on the GaN optical properties during Cl2/SiCl4/Ar plasma etching was evaluated using photoluminescence (PL) analysis. The samples were exposed to plasma (radicals, ions, and UV light) using an inductively coupled plasma (ICP) etching system and a plasma ion beam apparatus that can separate the effects of UV and ions both with and without covering the SiO2 window on the surface. Etching damage in an InGaN single quantum well (SQW) was formed by exposing the sample to plasma. The damage, which decreases PL emission intensity, was generated not only by ion beam irradiation but also by UV light irradiation. PL intensity decreased when the thickness of the upper GaN layer was etched to less than 60 nm. In addition, simultaneous irradiation of UV light and ions slightly increased the degree of damage. There seems to be a synergistic effect between the UV light and the ions. For high-quality GaN-based optoelectronics and power devices, UV light must be controlled during etching processes in addition to the etching profile, selectivity, and ion bombardment damage.

  10. Simple, miniaturized blood plasma extraction method.

    PubMed

    Kim, Jin-Hee; Woenker, Timothy; Adamec, Jiri; Regnier, Fred E

    2013-12-03

    A rapid plasma extraction technology that collects a 2.5 μL aliquot of plasma within three minutes from a finger-stick derived drop of blood was evaluated. The utility of the plasma extraction cards used was that a paper collection disc bearing plasma was produced that could be air-dried in fifteen minutes and placed in a mailing envelop for transport to an analytical laboratory. This circumvents the need for venipuncture and blood collection in specialized vials by a phlebotomist along with centrifugation and refrigerated storage. Plasma extraction was achieved by applying a blood drop to a membrane stack through which plasma was drawn by capillary action. During the course of plasma migration to a collection disc at the bottom of the membrane stack blood cells were removed by a combination of adsorption and filtration. After the collection disc filled with an aliquot of plasma the upper membranes were stripped from the collection card and the collection disc was air-dried. Intercard differences in the volume of plasma collected varied approximately 1% while volume variations of less than 2% were seen with hematocrit levels ranging from 20% to 71%. Dried samples bearing metabolites and proteins were then extracted from the disc and analyzed. 25-Hydroxy vitamin D was quantified by LC-MS/MS analysis following derivatization with a secosteroid signal enhancing tag that imparted a permanent positive charge to the vitamin and reduced the limit of quantification (LOQ) to 1 pg of collected vitamin on the disc; comparable to values observed with liquid-liquid extraction (LLE) of a venipuncture sample. A similar study using conventional proteomics methods and spectral counting for quantification was conducted with yeast enolase added to serum as an internal standard. The LOQ with extracted serum samples for enolase was 1 μM, linear from 1 to 40 μM, the highest concentration examined. In all respects protein quantification with extracted serum samples was comparable to that observed with serum samples obtained by venipuncture.

  11. Ultra-micro analysis of liquids and suspensions based on laser-induced plasma emissions

    NASA Astrophysics Data System (ADS)

    Cheung, N. H.; Ng, C. W.; Ho, W. F.; Yeung, E. S.

    1998-05-01

    Spectrochemical analysis of liquids and suspensions using laser-induced plasma emissions was investigated. Nd:YAG pulsed-laser (532-nm) ablation of aqueous samples produced plasmas that were hot (few eV) and extensively ionized, with electron density in the 10 18 cm -3 range. Analyte line signals were initially masked by intense plasma continuum emissions, and would only emerge briefly above the background when the plume temperature dropped below 1 eV during the course of its very rapid cooling. In contrast, 193-nm laser ablation at similar fluence generated plasmas of much lower (<1 eV) temperature but comparable electron density. The plasma continuum emissions were relatively weak and the signal-to-background ratio was a thousand times better. This `cold' plasma was ideal for sampling trace amounts of biologically important elements such as sodium and potassium. By ablating hydrodynamically focused jets in a sheath-flow, and with acoustic normalization for improved precision, the single-shot detection limits of sodium and potassium were 8 and 50 fg, respectively. Using the sheath-flow arrangement, the amounts of sodium and potassium inside single human red blood cells were simultaneously determined for the first time. The intracellular contents for a given blood donor were found to vary significantly, with only very weak correlation between the amounts of sodium and potassium in individual cells.

  12. Multivariate classification of edible salts: Simultaneous Laser-Induced Breakdown Spectroscopy and Laser-Ablation Inductively Coupled Plasma Mass Spectrometry Analysis

    NASA Astrophysics Data System (ADS)

    Lee, Yonghoon; Nam, Sang-Ho; Ham, Kyung-Sik; Gonzalez, Jhanis; Oropeza, Dayana; Quarles, Derrick; Yoo, Jonghyun; Russo, Richard E.

    2016-04-01

    Laser-Induced Breakdown Spectroscopy (LIBS) and Laser-Ablation Inductively Coupled Plasma Mass Spectrometry (LA-ICP-MS), both based on laser ablation sampling, can be employed simultaneously to obtain different chemical fingerprints from a sample. We demonstrated that this analysis approach can provide complementary information for improved classification of edible salts. LIBS could detect several of the minor metallic elements along with Na and Cl, while LA-ICP-MS spectra were used to measure non-metallic and trace heavy metal elements. Principal component analysis using LIBS and LA-ICP-MS spectra showed that their major spectral variations classified the sample salts in different ways. Three classification models were developed by using partial least squares-discriminant analysis based on the LIBS, LA-ICP-MS, and their fused data. From the cross-validation performances and confusion matrices of these models, the minor metallic elements (Mg, Ca, and K) detected by LIBS and the non-metallic (I) and trace heavy metal (Ba, W, and Pb) elements detected by LA-ICP-MS provided complementary chemical information to distinguish particular salt samples.

  13. Novel micro-extraction by packed sorbent procedure for the liquid chromatographic analysis of antiepileptic drugs in human plasma and urine.

    PubMed

    Rani, Susheela; Malik, Ashok K; Singh, Baldev

    2012-02-01

    A method for the simultaneous determination of the antiepileptic drugs, phenobarbital (PHB), phenytoin (PTN), carbamazepine (CBZ), primidone (PRM) and oxcarbazepine (OXC) in human plasma and urine samples by using micro-extraction in a packed syringe as the sample preparation method connected with LC/UV (MEPS/LC/UV) is described. Micro-extraction in a packed syringe (MEPS) is a new miniaturized, solid-phase extraction technique that can be connected online to gas or liquid chromatography without any modifications. In MEPS approximately 1 mg of the solid packing material is inserted into a syringe (100-250 μL) as a plug. Sample preparation takes place on the packed bed. The bed can be coated to provide selective and suitable sampling conditions. The new method is very promising, easy to use, fully automated, inexpensive and quick. The standard curves were obtained within the concentration range 1-500 ng/mL in both plasma and urine samples. The results showed high correlation coefficients (R(2) >0.988) for all of the analytes within the calibration range. The extraction recovery was found to be between 88.56 and 99.38%. The limit of quantification was found to be between 0.132 and 1.956 ng/mL. The precision (RSD) values of quality control samples (QC) had a maximum deviation of 4.9%. A comparison of the detection limits with similar methods indicates high sensitivity of the present method. The method is applied for the analysis of these drugs in real urine and plasma samples of epileptic patients. Copyright © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. Comparison of Performance Characteristics of Aspergillus PCR in Testing a Range of Blood-Based Samples in Accordance with International Methodological Recommendations.

    PubMed

    Springer, Jan; White, P Lewis; Hamilton, Shanna; Michel, Denise; Barnes, Rosemary A; Einsele, Hermann; Löffler, Juergen

    2016-03-01

    Standardized methodologies for the molecular detection of invasive aspergillosis (IA) have been established by the European Aspergillus PCR Initiative for the testing of whole blood, serum, and plasma. While some comparison of the performance of Aspergillus PCR when testing these different sample types has been performed, no single study has evaluated all three using the recommended protocols. Standardized Aspergillus PCR was performed on 423 whole-blood pellets (WBP), 583 plasma samples, and 419 serum samples obtained from hematology patients according to the recommendations. This analysis formed a bicenter retrospective anonymous case-control study, with diagnosis according to the revised European Organization for Research and Treatment of Cancer/Invasive Fungal Infections Cooperative Group and National Institute of Allergy and Infectious Diseases Mycoses Study Group (EORTC/MSG) consensus definitions (11 probable cases and 36 controls). Values for clinical performance using individual and combined samples were calculated. For all samples, PCR positivity was significantly associated with cases of IA (for plasma, P = 0.0019; for serum, P = 0.0049; and for WBP, P = 0.0089). Plasma PCR generated the highest sensitivity (91%); the sensitivities for serum and WBP PCR were 80% and 55%, respectively. The highest specificity was achieved when testing WBP (96%), which was significantly superior to the specificities achieved when testing serum (69%, P = 0.0238) and plasma (53%, P = 0.0002). No cases were PCR negative in all specimen types, and no controls were PCR positive in all specimens. This study confirms that Aspergillus PCR testing of plasma provides robust performance while utilizing commercial automated DNA extraction processes. Combining PCR testing of different blood fractions allows IA to be both confidently diagnosed and excluded. A requirement for multiple PCR-positive plasma samples provides similar diagnostic utility and is technically less demanding. Time to diagnosis may be enhanced by testing multiple contemporaneously obtained sample types. Copyright © 2016, American Society for Microbiology. All Rights Reserved.

  15. Multifocal clonal evolution characterized using circulating tumour DNA in a case of metastatic breast cancer

    PubMed Central

    Murtaza, Muhammed; Dawson, Sarah-Jane; Pogrebniak, Katherine; Rueda, Oscar M.; Provenzano, Elena; Grant, John; Chin, Suet-Feung; Tsui, Dana W. Y.; Marass, Francesco; Gale, Davina; Ali, H. Raza; Shah, Pankti; Contente-Cuomo, Tania; Farahani, Hossein; Shumansky, Karey; Kingsbury, Zoya; Humphray, Sean; Bentley, David; Shah, Sohrab P.; Wallis, Matthew; Rosenfeld, Nitzan; Caldas, Carlos

    2015-01-01

    Circulating tumour DNA analysis can be used to track tumour burden and analyse cancer genomes non-invasively but the extent to which it represents metastatic heterogeneity is unknown. Here we follow a patient with metastatic ER-positive and HER2-positive breast cancer receiving two lines of targeted therapy over 3 years. We characterize genomic architecture and infer clonal evolution in eight tumour biopsies and nine plasma samples collected over 1,193 days of clinical follow-up using exome and targeted amplicon sequencing. Mutation levels in the plasma samples reflect the clonal hierarchy inferred from sequencing of tumour biopsies. Serial changes in circulating levels of sub-clonal private mutations correlate with different treatment responses between metastatic sites. This comparison of biopsy and plasma samples in a single patient with metastatic breast cancer shows that circulating tumour DNA can allow real-time sampling of multifocal clonal evolution. PMID:26530965

  16. Multifocal clonal evolution characterized using circulating tumour DNA in a case of metastatic breast cancer.

    PubMed

    Murtaza, Muhammed; Dawson, Sarah-Jane; Pogrebniak, Katherine; Rueda, Oscar M; Provenzano, Elena; Grant, John; Chin, Suet-Feung; Tsui, Dana W Y; Marass, Francesco; Gale, Davina; Ali, H Raza; Shah, Pankti; Contente-Cuomo, Tania; Farahani, Hossein; Shumansky, Karey; Kingsbury, Zoya; Humphray, Sean; Bentley, David; Shah, Sohrab P; Wallis, Matthew; Rosenfeld, Nitzan; Caldas, Carlos

    2015-11-04

    Circulating tumour DNA analysis can be used to track tumour burden and analyse cancer genomes non-invasively but the extent to which it represents metastatic heterogeneity is unknown. Here we follow a patient with metastatic ER-positive and HER2-positive breast cancer receiving two lines of targeted therapy over 3 years. We characterize genomic architecture and infer clonal evolution in eight tumour biopsies and nine plasma samples collected over 1,193 days of clinical follow-up using exome and targeted amplicon sequencing. Mutation levels in the plasma samples reflect the clonal hierarchy inferred from sequencing of tumour biopsies. Serial changes in circulating levels of sub-clonal private mutations correlate with different treatment responses between metastatic sites. This comparison of biopsy and plasma samples in a single patient with metastatic breast cancer shows that circulating tumour DNA can allow real-time sampling of multifocal clonal evolution.

  17. Quantitative bioanalysis of strontium in human serum by inductively coupled plasma-mass spectrometry

    PubMed Central

    Somarouthu, Srikanth; Ohh, Jayoung; Shaked, Jonathan; Cunico, Robert L; Yakatan, Gerald; Corritori, Suzana; Tami, Joe; Foehr, Erik D

    2015-01-01

    Aim: A bioanalytical method using inductively-coupled plasma-mass spectrometry to measure endogenous levels of strontium in human serum was developed and validated. Results & methodology: This article details the experimental procedures used for the method development and validation thus demonstrating the application of the inductively-coupled plasma-mass spectrometry method for quantification of strontium in human serum samples. The assay was validated for specificity, linearity, accuracy, precision, recovery and stability. Significant endogenous levels of strontium are present in human serum samples ranging from 19 to 96 ng/ml with a mean of 34.6 ± 15.2 ng/ml (SD). Discussion & conclusion: Calibration procedures and sample pretreatment were simplified for high throughput analysis. The validation demonstrates that the method was sensitive, selective for quantification of strontium (88Sr) and is suitable for routine clinical testing of strontium in human serum samples. PMID:28031925

  18. Investigations into the Anti-Felting Properties of Sputtered Wool Using Plasma Treatment

    NASA Astrophysics Data System (ADS)

    M. Borghei, S.; Shahidi, S.; Ghoranneviss, M.; Abdolahi, Z.

    2013-01-01

    In this research the effects of mordant and plasma sputtering treatments on the crystallinity and morphological properties of wool fabrics were investigated. The felting behavior of the treated samples was also studied. We used madder as a natural dye and copper sulfate as a metal mordant. We also used copper as the electrode material in a DC magnetron plasma sputtering device. The anti-felting properties of the wool samples before and after dying was studied, and it was shown that the shrink resistance and anti-felting behavior of the wool had been significantly improved by the plasma sputtering treatment. In addition, the percentage of crystallinity and the size of the crystals were investigated using an X-ray diffractometer, and a scanning electron microscope was used for morphological analysis. The amount of copper particles on the surface of the mordanted and sputtered fabrics was studied using the energy dispersive X-ray (EDX) method, and the hydrophobic properties of the samples were examined using the water drop test. The results show that with plasma sputtering treatment, the hydrophobic properties of the surface of wool become super hydrophobic.

  19. Transport of nattokinase across the rat intestinal tract.

    PubMed

    Fujita, M; Hong, K; Ito, Y; Misawa, S; Takeuchi, N; Kariya, K; Nishimuro, S

    1995-09-01

    Intraduodenal administration of nattokinase (NK) at a dose of 80 mg/kg, resulted in the degradation of fibrinogen in plasma suggesting transport of NK across the intestinal tract in normal rats. The action of NK on the cleavage of fibrinogen in the plasma from blood samples drawn at intervals after intraduodenal administration of the enzyme was investigated by sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE) and Western blotting analysis with an anti-fibrinogen gamma chain antibody. The 270 kDa fragment carrying antigenic sites for the binding of the anti-fibrinogen gamma chain antibody appeared within 0.5 h and was then degraded gradually to a 105 kDa fragment via a 200 kDa fragment. This suggests that fibrinogen was degraded to a 105 kDa fragment via several intermediates (270 and 200 kDa). In parallel with the degradation process, plasma recalcification times were remarkably prolonged NK was also detected in the plasma from blood samples drawn 3 and 5 h after administration of the enzyme by SDS-PAGE and Western blotting analysis with an anti-NK antibody. The results indicate that NK is absorbed from the rat intestinal tract and that NK cleaves fibrinogen in plasma after intraduodenal administration of the enzyme.

  20. Quantification of low molecular weight selenium metabolites in human plasma after treatment with selenite in pharmacological doses by LC-ICP-MS.

    PubMed

    Flouda, Konstantina; Dersch, Julie Maria; Gabel-Jensen, Charlotte; Stürup, Stefan; Misra, Sougat; Björnstedt, Mikael; Gammelgaard, Bente

    2016-03-01

    The paper presents an analytical method for quantification of low molecular weight (LMW) selenium compounds in human plasma based on liquid chromatography inductively coupled plasma mass spectrometry (LC-ICP-MS) and post column isotope dilution-based quantification. Prior to analysis, samples were ultrafiltrated using a cut-off value of 3000 Da. The method was validated in aqueous solution as well as plasma using standards of selenomethionine (SeMet), Se-methylselenocysteine (MeSeCys), selenite, and the selenosugar Se-methylseleno-N-acetylgalactosamine (SeGal) for linearity, precision, recoveries, and limits of detection and quantitation with satisfactory results. The method was applied for analysis of a set of plasma samples from cancer patients receiving selenite treatment in a clinical trial. Three LMW selenium compounds were observed. The main compounds, SeGal and selenite were tentatively identified by retention time matching with standards in different chromatographic systems, while the third minor compound was not identified. The identity of the selenosugar was verified by ESI-MS-MS product ion scanning, while selenite was identified indirectly as the glutathione (GSH) reaction product, GS-Se-SG.

  1. Pre-treatment plasma proteomic markers associated with survival in oesophageal cancer

    PubMed Central

    Kelly, P; Paulin, F; Lamont, D; Baker, L; Clearly, S; Exon, D; Thompson, A

    2012-01-01

    Background: The incidence of oesophageal adenocarcinoma is increasing worldwide but survival remains poor. Neoadjuvant chemotherapy can improve survival, but prognostic and predictive biomarkers are required. This study built upon preclinical approaches to identify prognostic plasma proteomic markers in oesophageal cancer. Methods: Plasma samples collected before and during the treatment of oesophageal cancer and non-cancer controls were analysed by surface-enhanced laser desorption/ionisation time-of-flight (SELDI-TOF) mass spectroscopy (MS). Protein peaks were identified by MS in tryptic digests of purified fractions. Associations between peak intensities obtained in the spectra and clinical endpoints (survival, disease-free survival) were tested by univariate (Fisher's exact test) and multivariate analysis (binary logistic regression). Results: Plasma protein peaks were identified that differed significantly (P<0.05, ANOVA) between the oesophageal cancer and control groups at baseline. Three peaks, confirmed as apolipoprotein A-I, serum amyloid A and transthyretin, in baseline (pre-treatment) samples were associated by univariate and multivariate analysis with disease-free survival and overall survival. Conclusion: Plasma proteins can be detected prior to treatment for oesophageal cancer that are associated with outcome and merit testing as prognostic and predictive markers of response to guide chemotherapy in oesophageal cancer. PMID:22294182

  2. Pre-treatment plasma proteomic markers associated with survival in oesophageal cancer.

    PubMed

    Kelly, P; Paulin, F; Lamont, D; Baker, L; Clearly, S; Exon, D; Thompson, A

    2012-02-28

    The incidence of oesophageal adenocarcinoma is increasing worldwide but survival remains poor. Neoadjuvant chemotherapy can improve survival, but prognostic and predictive biomarkers are required. This study built upon preclinical approaches to identify prognostic plasma proteomic markers in oesophageal cancer. Plasma samples collected before and during the treatment of oesophageal cancer and non-cancer controls were analysed by surface-enhanced laser desorption/ionisation time-of-flight (SELDI-TOF) mass spectroscopy (MS). Protein peaks were identified by MS in tryptic digests of purified fractions. Associations between peak intensities obtained in the spectra and clinical endpoints (survival, disease-free survival) were tested by univariate (Fisher's exact test) and multivariate analysis (binary logistic regression). Plasma protein peaks were identified that differed significantly (P<0.05, ANOVA) between the oesophageal cancer and control groups at baseline. Three peaks, confirmed as apolipoprotein A-I, serum amyloid A and transthyretin, in baseline (pre-treatment) samples were associated by univariate and multivariate analysis with disease-free survival and overall survival. Plasma proteins can be detected prior to treatment for oesophageal cancer that are associated with outcome and merit testing as prognostic and predictive markers of response to guide chemotherapy in oesophageal cancer.

  3. Early Detection of Pressure Ulcer Development Following Traumatic Spinal Cord Injury Using Inflammatory Mediators.

    PubMed

    Krishnan, Shilpa; Karg, Patricia E; Boninger, Michael L; Vodovotz, Yoram; Constantine, Greg; Sowa, Gwendolyn A; Brienza, David M

    2016-10-01

    To identify changes in concentrations of inflammatory mediators in plasma and urine after traumatic spinal cord injury (SCI) and before the occurrence of a first pressure ulcer. Retrospective; secondary analysis of existing data. Acute hospitalization and inpatient rehabilitation sites at a university medical center. Individuals with a pressure ulcer and plasma samples (n=17) and individuals with a pressure ulcer and urine samples (n=15) were matched by age and plasma/urine sample days to individuals with SCI and no pressure ulcer (N=35). Not applicable. Plasma and urine samples were assayed in patients with SCI, capturing samples within 4 days after the SCI to a week before the formation of the first pressure ulcer. The Wilcoxon signed-rank test was performed to identify changes in the inflammatory mediators between the 2 time points. An increase in concentration of the chemokine interferon-γ-induced protein of 10kd/CXCL10 in plasma (P<.01) and a decrease in concentration of the cytokine interferon-α in urine (P=.01) were observed before occurrence of a first pressure ulcer (∼4d) compared with matched controls. Altered levels of inflammatory mediators in plasma and urine may be associated with pressure ulcer development after traumatic SCI. These inflammatory mediators should be explored as possible biomarkers for identifying individuals at risk for pressure ulcer formation. Copyright © 2016 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  4. Green and Fast Laser Fusion Technique for Bulk Silicate Rock Analysis by Laser Ablation-Inductively Coupled Plasma Mass Spectrometry.

    PubMed

    Zhang, Chenxi; Hu, Zhaochu; Zhang, Wen; Liu, Yongsheng; Zong, Keqing; Li, Ming; Chen, Haihong; Hu, Shenghong

    2016-10-18

    Sample preparation of whole-rock powders is the major limitation for their accurate and precise elemental analysis by laser ablation inductively-coupled plasma mass spectrometry (ICPMS). In this study, a green, efficient, and simplified fusion technique using a high energy infrared laser was developed for major and trace elemental analysis. Fusion takes only tens of milliseconds for each sample. Compared to the pressed pellet sample preparation, the analytical precision of the developed laser fusion technique is higher by an order of magnitude for most elements in granodiorite GSP-2. Analytical results obtained for five USGS reference materials (ranging from mafic to intermediate to felsic) using the laser fusion technique generally agree with recommended values with discrepancies of less than 10% for most elements. However, high losses (20-70%) of highly volatile elements (Zn and Pb) and the transition metal Cu are observed. The achieved precision is within 5% for major elements and within 15% for most trace elements. Direct laser fusion of rock powders is a green and notably simple method to obtain homogeneous samples, which will significantly accelerate the application of laser ablation ICPMS for whole-rock sample analysis.

  5. Analysis and stability of retinol in plasma.

    PubMed

    Peng, Y M; Xu, M J; Alberts, D S

    1987-01-01

    A simple, precise, and specific high-performance liquid chromatography (HPLC) method was developed for the simultaneous measurement of retinol (ROH), 13-cis-retinoic acid (13-cRA), and 4-oxo-13-cRA. The average recovery of ROH from serum or plasma was 95%, and the precision of the assay was less than 5%. With this HPLC method, a series of studies was carried out to evaluate the stability of ROH in various matrices. ROH was stable under our HPLC assay conditions as well as in plasma- and in serum-enriched culture media; however, ROH was not stable in aqueous matrices. Serum or heparinized plasma may be routinely used for measurement of ROH concentrations, providing EDTA, oxalate, and citrate are not used as anticoagulants. Because of ROH stability, blood samples can be kept on ice in the dark for at least 24 hours prior to separation of plasma. In addition, plasma samples containing ROH can be stored for up to 1 year at -20 degrees C without loss of stability.

  6. Robotic solid phase extraction and high performance liquid chromatographic analysis of ranitidine in serum or plasma.

    PubMed

    Lloyd, T L; Perschy, T B; Gooding, A E; Tomlinson, J J

    1992-01-01

    A fully automated assay for the analysis of ranitidine in serum and plasma, with and without an internal standard, was validated. It utilizes robotic solid phase extraction with on-line high performance liquid chromatographic (HPLC) analysis. The ruggedness of the assay was demonstrated over a three-year period. A Zymark Py Technology II robotic system was used for serial processing from initial aspiration of samples from original collection containers, to final direct injection onto the on-line HPLC system. Automated serial processing with on-line analysis provided uniform sample history and increased productivity by freeing the chemist to analyse data and perform other tasks. The solid phase extraction efficiency was 94% throughout the assay range of 10-250 ng/mL. The coefficients of variation for within- and between-day quality control samples ranged from 1 to 6% and 1 to 5%, respectively. Mean accuracy for between-day standards and quality control results ranged from 97 to 102% of the respective theoretical concentrations.

  7. Temperature effect on laser-induced breakdown spectroscopy spectra of molten and solid salts

    NASA Astrophysics Data System (ADS)

    Hanson, Cynthia; Phongikaroon, Supathorn; Scott, Jill R.

    2014-07-01

    Laser-induced breakdown spectroscopy (LIBS) has been investigated as a potential analytical tool to improve operations and safeguards for electrorefiners, such as those used in processing spent nuclear fuel. This study set out to better understand the effect of sample temperature and physical state on LIBS spectra of molten and solid salts by building calibration curves of cerium and assessing self-absorption, plasma temperature, electron density, and local thermal equilibrium (LTE). Samples were composed of a LiCl-KCl eutectic salt, an internal standard of MnCl2, and varying concentrations of CeCl3 (0.1, 0.3, 0.5, 0.8, and 1.0 wt.% Ce) under different temperatures (773, 723, 673, 623, and 573 K). Analysis of salts in their molten form is preferred as plasma plumes from molten samples experienced less self-absorption, less variability in plasma temperature, and higher clearance of the minimum electron density required for local thermal equilibrium. These differences are attributed to plasma dynamics as a result of phase changes. Spectral reproducibility was also better in the molten state due to sample homogeneity.

  8. A validated ultra-high-performance liquid chromatography-tandem mass spectrometry method for the selective analysis of free and total folate in plasma and red blood cells.

    PubMed

    Kiekens, Filip; Van Daele, Jeroen; Blancquaert, Dieter; Van Der Straeten, Dominique; Lambert, Willy E; Stove, Christophe P

    2015-06-12

    A stable isotope dilution LC-MS/MS method is the method of choice for the selective quantitative determination of several folate species in clinical samples. By implementing an integrated approach to determine both the plasma and red blood cell (RBC) folate status, the use of consumables and time remains limited. Starting from a single 300μl whole blood sample, the folate status in plasma and RBCs can be determined after separating plasma and RBCs and sequential washing of the latter with isotonic buffer, followed by reproducible lysis using an ammonium-based buffer. Acidification combines both liberation of protein bound folates and protein precipitation. Sample cleanup is performed using a 96-well reversed-phase solid-phase extraction procedure, similar for both plasma and RBC samples. Analyses are performed by UHPLC-MS/MS. Method validation was successfully performed based on EMA-guidelines and encompassed selectivity, carry-over, linearity, accuracy, precision, recovery, matrix effect and stability. Plasma and RBC folates could be quantified in the range of 1-150nmol/l and 5-1500nmol/l, respectively. This method allows for the determination of 6 folate monoglutamates in both plasma and RBCs. It can be used to determine short and long term folate status in both normal and severely deficient subjects in a single analytical sequence. Copyright © 2015 Elsevier B.V. All rights reserved.

  9. Atmospheric plasma surface modifications of electrospun PCL/chitosan/PCL hybrid scaffolds by nozzle type plasma jets for usage of cell cultivation

    NASA Astrophysics Data System (ADS)

    Surucu, Seda; Masur, Kai; Turkoglu Sasmazel, Hilal; Von Woedtke, Thomas; Weltmann, Klaus Dieter

    2016-11-01

    This paper reports Ar gas, Ar + O2, Ar + O2 + N2 gas mixtures and dry air plasma modifications by atmospheric pressure argon driven kINPen and air driven Diener (PlasmaBeam) plasma jets to alter surface properties of three dimensional (3D), electrospun PCL/Chitosan/PCL layer by layer hybrid scaffolds to improve human fibroblast (MRC5) cell attachment and growth. The characterizations of the samples were done by contact angle (CA) measurements, scanning electron microscopy (SEM), X-Ray Photoelectron spectroscopy (XPS) analysis. The results showed that the plasma modification carried out under dry air and Ar + O2 + N2 gas mixtures were altered effectively the nanotopography and the functionality of the material surfaces. It was found that the samples treated with Ar + O2 + N2 gas mixtures for 1 min and dry air for 9 min have better hydrophilicity 78.9° ± 1.0 and 75.6° ± 0.1, respectively compared to the untreated samples (126.5°). Biocompatibility performance of the scaffolds was determined with alamarBlue (aB) assay and MTT assay methods, Giemsa staining, fluorescence microscope, confocal laser scanning microscope (CLSM) and scanning electron microscope (SEM) analyses. The results showed that plasma treated samples increased the hydrophilicity and oxygen functionality and topography of the surfaces significantly, thus affecting the cell viability and proliferation on/within scaffolds.

  10. Lithogeochemistry of mineralized and altered rock samples from the northern Talkeetna Mountains, south-central Alaska

    USGS Publications Warehouse

    Light, Thomas D.; Schmidt, Jeanine M.

    2011-01-01

    Mineralized and altered rock samples collected from the northern Talkeetna Mountains, Alaska, were analyzed by two different inductively coupled plasma atomic-emission spectrometry (ICP-AES) methods for as many as 44 elements; by fire assay and either direct-coupled plasma (DCP) or atomic absorption spectrophotometry (AAS) for gold (Au); by cold vapor atomic absorption (CVAA) for mercury (Hg); and by irradiated neutron activation analysis (INAA) for tungsten (W). The analytical results showed that some samples contain high values of multiple elements and may be potential indicators of hydrothermal mineralization in the area.

  11. Tumor and Plasma Met Levels in Non-Metastatic Prostate Cancer.

    PubMed

    Kaye, Deborah R; Pinto, Peter A; Cecchi, Fabiola; Reilly, Joseph; Semerjian, Alice; Rabe, Daniel C; Gupta, Gopal; Choyke, Peter L; Bottaro, Donald P

    2016-01-01

    To measure Met protein content in prostate biopsies guided by fused magnetic resonance and ultrasound imaging, and to measure soluble Met (sMet) protein concentration in plasma samples from patients presenting evidence of prostate cancer. 345 patients had plasma samples drawn prior to image-guided biopsy of the prostate. Of these, 32% had benign biopsies. Of the 236 that were positive for prostate adenocarcinoma (PCa), 132 treated by total prostatectomy had Gleason scores of 6 (17%), 7, (55%), 8 (16%), or 9-10 (12%). 23% had evidence of local invasion. Plasma samples were also obtained from 80 healthy volunteers. Tissue Met and plasma sMet were measured by two-site immunoassay; values were compared among clinically defined groups using non-parametric statistical tests to determine significant differences or correlations. PCa tumor Met correlated significantly with plasma sMet, but median values were similar among benign and malignant groups. Median plasma sMet values were also similar among those groups, although both medians were significantly above normal. Median Met content in primary PCa tumors and sMet concentrations were independent of Gleason score, final pathologic stage and age. Plasma sMet is not predictive of PCa or its severity in patients with organ-confined or locally invasive disease. Quantitative analysis of Met protein content and activation state in PCa tumor biopsy samples was highly feasible and may have value in follow-up to genomic and/or transcriptomic-based screens that show evidence of oncogenically relevant MET gene features that occur at relatively low frequency in non-metastatic PCa.

  12. A simple high performance liquid chromatography method for determination of rebamipide in rat urine.

    PubMed

    Cooper, Dustin L; Harirforoosh, Sam

    2014-01-01

    Rebamipide is a mucoprotective agent commonly used to prevent nonsteriodal anti-inflammatory drug-induced gastrointenstinal side effects [1]. Human plasma and urine analysis of rebamipide utilizing high performance liquid chromatography (HPLC) have been reported [2]. Recently, we reported on the plasma levels of rebamipide in presense or absence of celecoxib or diclofenac in rats [3] using a modified HPLC method of detection developed by Jeoung et al. [4]. To tailor the method towards use in urinary rebamipide extraction and analysis, the following modifications were made:•To compensate for high concentrations of rebamipide found in urine, a new rebamipide stock solution was prepared with a final concentration of 50,000 ng/mL.•Rat urine calibration standards were obtained within the range of 50-1000 ng/mL and 1000-50,000 ng/mL.•Plasma samples were replaced with urine samples.

  13. Provenance establishment of coffee using solution ICP-MS and ICP-AES.

    PubMed

    Valentin, Jenna L; Watling, R John

    2013-11-01

    Statistical interpretation of the concentrations of 59 elements, determined using solution based inductively coupled plasma mass spectrometry (ICP-MS) and inductively coupled plasma emission spectroscopy (ICP-AES), was used to establish the provenance of coffee samples from 15 countries across five continents. Data confirmed that the harvest year, degree of ripeness and whether the coffees were green or roasted had little effect on the elemental composition of the coffees. The application of linear discriminant analysis and principal component analysis of the elemental concentrations permitted up to 96.9% correct classification of the coffee samples according to their continent of origin. When samples from each continent were considered separately, up to 100% correct classification of coffee samples into their countries, and plantations of origin was achieved. This research demonstrates the potential of using elemental composition, in combination with statistical classification methods, for accurate provenance establishment of coffee. Copyright © 2013 Elsevier Ltd. All rights reserved.

  14. The requirements for low-temperature plasma ionization support miniaturization of the ion source.

    PubMed

    Kiontke, Andreas; Holzer, Frank; Belder, Detlev; Birkemeyer, Claudia

    2018-06-01

    Ambient ionization mass spectrometry (AI-MS), the ionization of samples under ambient conditions, enables fast and simple analysis of samples without or with little sample preparation. Due to their simple construction and low resource consumption, plasma-based ionization methods in particular are considered ideal for use in mobile analytical devices. However, systematic investigations that have attempted to identify the optimal configuration of a plasma source to achieve the sensitive detection of target molecules are still rare. We therefore used a low-temperature plasma ionization (LTPI) source based on dielectric barrier discharge with helium employed as the process gas to identify the factors that most strongly influence the signal intensity in the mass spectrometry of species formed by plasma ionization. In this study, we investigated several construction-related parameters of the plasma source and found that a low wall thickness of the dielectric, a small outlet spacing, and a short distance between the plasma source and the MS inlet are needed to achieve optimal signal intensity with a process-gas flow rate of as little as 10 mL/min. In conclusion, this type of ion source is especially well suited for downscaling, which is usually required in mobile devices. Our results provide valuable insights into the LTPI mechanism; they reveal the potential to further improve its implementation and standardization for mobile mass spectrometry as well as our understanding of the requirements and selectivity of this technique. Graphical abstract Optimized parameters of a dielectric barrier discharge plasma for ionization in mass spectrometry. The electrode size, shape, and arrangement, the thickness of the dielectric, and distances between the plasma source, sample, and MS inlet are marked in red. The process gas (helium) flow is shown in black.

  15. Plasma exosome microRNAs are indicative of breast cancer.

    PubMed

    Hannafon, Bethany N; Trigoso, Yvonne D; Calloway, Cameron L; Zhao, Y Daniel; Lum, David H; Welm, Alana L; Zhao, Zhizhuang J; Blick, Kenneth E; Dooley, William C; Ding, W Q

    2016-09-08

    microRNAs are promising candidate breast cancer biomarkers due to their cancer-specific expression profiles. However, efforts to develop circulating breast cancer biomarkers are challenged by the heterogeneity of microRNAs in the blood. To overcome this challenge, we aimed to develop a molecular profile of microRNAs specifically secreted from breast cancer cells. Our first step towards this direction relates to capturing and analyzing the contents of exosomes, which are small secretory vesicles that selectively encapsulate microRNAs indicative of their cell of origin. To our knowledge, circulating exosome microRNAs have not been well-evaluated as biomarkers for breast cancer diagnosis or monitoring. Exosomes were collected from the conditioned media of human breast cancer cell lines, mouse plasma of patient-derived orthotopic xenograft models (PDX), and human plasma samples. Exosomes were verified by electron microscopy, nanoparticle tracking analysis, and western blot. Cellular and exosome microRNAs from breast cancer cell lines were profiled by next-generation small RNA sequencing. Plasma exosome microRNA expression was analyzed by qRT-PCR analysis. Small RNA sequencing and qRT-PCR analysis showed that several microRNAs are selectively encapsulated or highly enriched in breast cancer exosomes. Importantly, the selectively enriched exosome microRNA, human miR-1246, was detected at significantly higher levels in exosomes isolated from PDX mouse plasma, indicating that tumor exosome microRNAs are released into the circulation and can serve as plasma biomarkers for breast cancer. This observation was extended to human plasma samples where miR-1246 and miR-21 were detected at significantly higher levels in the plasma exosomes of 16 patients with breast cancer as compared to the plasma exosomes of healthy control subjects. Receiver operating characteristic curve analysis indicated that the combination of plasma exosome miR-1246 and miR-21 is a better indicator of breast cancer than their individual levels. Our results demonstrate that certain microRNA species, such as miR-21 and miR-1246, are selectively enriched in human breast cancer exosomes and significantly elevated in the plasma of patients with breast cancer. These findings indicate a potential new strategy to selectively analyze plasma breast cancer microRNAs indicative of the presence of breast cancer.

  16. Comparison method for uranium determination in ore sample by inductively coupled plasma optical emission spectrometry (ICP-OES).

    PubMed

    Sert, Şenol

    2013-07-01

    A comparison method for the determination (without sample pre-concentration) of uranium in ore by inductively coupled plasma optical emission spectrometry (ICP-OES) has been performed. The experiments were conducted using three procedures: matrix matching, plasma optimization, and internal standardization for three emission lines of uranium. Three wavelengths of Sm were tested as internal standard for the internal standardization method. The robust conditions were evaluated using applied radiofrequency power, nebulizer argon gas flow rate, and sample uptake flow rate by considering the intensity ratio of the Mg(II) 280.270 nm and Mg(I) 285.213 nm lines. Analytical characterization of method was assessed by limit of detection and relative standard deviation values. The certificated reference soil sample IAEA S-8 was analyzed, and the uranium determination at 367.007 nm with internal standardization using Sm at 359.260 nm has been shown to improve accuracy compared with other methods. The developed method was used for real uranium ore sample analysis.

  17. Plasma lactate concentrations in free-ranging moose (Alces alces) immobilized with etorphine.

    PubMed

    Haga, Henning A; Wenger, Sandra; Hvarnes, Silje; Os, Oystein; Rolandsen, Christer M; Solberg, Erling J

    2009-11-01

    To investigate plasma lactate concentrations of etorphine-immobilized moose in relation to environmental, temporal and physiological parameters. Prospective clinical study. Fourteen female and five male moose (Alces alces), estimated age range 1-7 years. The moose were darted from a helicopter with 7.5 mg etorphine per animal using projectile syringes and a dart gun. Once immobilized, the moose were approached, a venous blood sample was obtained and vital signs including pulse oximetry were recorded. Diprenorphine was administered to reverse the effects of etorphine. Timing of events, ambient temperature and snow depth were recorded. Blood samples were cooled and centrifuged before plasma was harvested and frozen. The plasma was thawed later and lactate analysed. Data were analysed using descriptive statistics and regression analysis. All animals recovered uneventfully and were alive 12 weeks after immobilization. Mean +/- SD plasma lactate was found to be 9.2 +/- 2.1 mmol L(-1). Plasma lactate concentrations were related positively to snow depth and negatively to time from induction of immobilization to blood sampling. The model that best described the variability in plasma lactate concentrations used induction time (time from firing the dart to the moose being immobilized). The second best model included induction time and snow depth. Plasma lactate concentrations in these etorphine-immobilized moose were in the range reported for other immobilized wild ruminants. Decreasing induction time, which may be related to a more profound etorphine effect, and increasing snow depth possibly may increase plasma lactate concentrations in etorphine-immobilized moose.

  18. Strong emission from nano-iron using laser-induced breakdown spectroscopy technique

    NASA Astrophysics Data System (ADS)

    Rashid, F. F.; ELSherbini, A. M.; Al-Muhamady, A.

    2014-06-01

    In this paper, we report a strong enhanced emission from laser produced plasma in air from iron oxide nano-material in comparison with the corresponding bulk samples. The enhancement strength differs with different Nd:YAG laser harmonics wavelengths. The analysis showed that such enhancement increased exponentially with the plasma evolution time, while it declines as the laser fluence increased. Experimental data analysis clearly showed that the observed enhancement is mainly associated with the change in the plasma electron density. We claim that this strong enhanced optical emission from laser produced plasma is due to the surface plasmon resonant excitation preferably on nano-oxide materials. Such experimental findings could improve the laser-induced breakdown spectroscopy sensitivity down to extremely low concentrations.

  19. Raman spectral analysis for rapid screening of dengue infection

    NASA Astrophysics Data System (ADS)

    Mahmood, T.; Nawaz, H.; Ditta, A.; Majeed, M. I.; Hanif, M. A.; Rashid, N.; Bhatti, H. N.; Nargis, H. F.; Saleem, M.; Bonnier, F.; Byrne, H. J.

    2018-07-01

    Infection with the dengue virus is currently clinically detected according to different biomarkers in human blood plasma, commonly measured by enzyme linked immunosorbent assays, including non-structural proteins (Ns1), immunoglobulin M (IgM) and immunoglobulin G (IgG). However, there is little or no mutual correlation between the biomarkers, as demonstrated in this study by a comparison of their levels in samples from 17 patients. As an alternative, the label free, rapid screening technique, Raman spectroscopy has been used for the characterisation/diagnosis of healthy and dengue infected human blood plasma samples. In dengue positive samples, changes in specific Raman spectral bands associated with lipidic and amino acid/protein content are observed and assigned based on literature and these features can be considered as markers associated with dengue development. Based on the spectroscopic analysis of the current, albeit limited, cohort of samples, Principal Components Analysis (PCA) coupled Factorial Discriminant Analysis, yielded values of 97.95% sensitivity and 95.40% specificity for identification of dengue infection. Furthermore, in a comparison of the normal samples to the patient samples which scored low for only one of the biomarker tests, but high or medium for either or both of the other two, PCA-FDA demonstrated a sensitivity of 97.38% and specificity of 86.18%, thus providing an unambiguous screening technology.

  20. (1)H-Nuclear magnetic resonance-based plasma metabolic profiling of dairy cows with clinical and subclinical ketosis.

    PubMed

    Sun, L W; Zhang, H Y; Wu, L; Shu, S; Xia, C; Xu, C; Zheng, J S

    2014-03-01

    The purpose of this study was to assess the metabolic profile of plasma samples from cows with clinical and subclinical ketosis. According to clinical signs and 3-hydroxybutyrate plasma levels, 81 multiparous Holstein cows were selected from a dairy farm 7 to 21 d after calving. The cows were divided into 3 groups: cows with clinical ketosis, cows with subclinical ketosis, and healthy control cows. (1)H-Nuclear magnetic resonance-based metabolomics was used to assess the plasma metabolic profiles of the 3 groups. The data were analyzed by principal component analysis, partial least squares discriminant analysis, and orthogonal partial least-squares discriminant analysis. The differences in metabolites among the 3 groups were assessed. The orthogonal partial least-squares discriminant analysis model differentiated the 3 groups of plasma samples. The model predicted clinical ketosis with a sensitivity of 100% and a specificity of 100%. In the case of subclinical ketosis, the model had a sensitivity of 97.0% and specificity of 95.7%. Twenty-five metabolites, including acetoacetate, acetone, lactate, glucose, choline, glutamic acid, and glutamine, were different among the 3 groups. Among the 25 metabolites, 4 were upregulated, 7 were downregulated, and 14 were both upregulated and downregulated. The results indicated that plasma (1)H-nuclear magnetic resonance-based metabolomics, coupled with pattern recognition analytical methods, not only has the sensitivity and specificity to distinguish cows with clinical and subclinical ketosis from healthy controls, but also has the potential to be developed into a clinically useful diagnostic tool that could contribute to a further understanding of the disease mechanisms. Copyright © 2014 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  1. Elemental analysis of bead samples using a laser-induced plasma at low pressure

    NASA Astrophysics Data System (ADS)

    Lie, Tjung Jie; Kurniawan, Koo Hendrik; Kurniawan, Davy P.; Pardede, Marincan; Suliyanti, Maria Margaretha; Khumaeni, Ali; Natiq, Shouny A.; Abdulmadjid, Syahrun Nur; Lee, Yong Inn; Kagawa, Kiichiro; Idris, Nasrullah; Tjia, May On

    2006-01-01

    An Nd:YAG laser (1064 nm, 8 ns, 30 mJ) was focused on various types of fresh, fossilized white coral and giant shell samples, including samples of imitation shell and marble. Such samples are extremely important as material for preparing prayer beads that are extensively used in the Buddhist faith. The aim of this research was to develop a non-destructive method to distinguish original beads from their imitations by means of spectral measurements of the carbon, hydrogen, sodium and magnesium emission intensities and by measuring the hardness of the sample using the ratio between Ca (II) 396.8 nm and Ca (I) 422.6 nm. Based on these measurements, original fresh coral beads can be distinguished from any imitation made from hard wood. The same technique was also effective in distinguishing beads made of shell from its imitation. A spectral analysis of bead was also performed on a fossilized white coral sample and the result can be used to distinguish to some extent the fossilized white coral beads from any imitation made from marble. It was also found that the plasma plume should be generated at low ambient pressure to significantly improve the hydrogen and carbon emission intensity and also to avoid energy loss inside the crater during laser irradiation at atmospheric pressure. The results of this study confirm that operating the laser-induced plasma spectroscopy at reduced ambient pressure offers distinct advantage for bead analysis over the conventional laser-induced breakdown spectroscopy (LIBS) technique operated at atmospheric pressure.

  2. An automated method for the analysis of phenolic acids in plasma based on ion-pairing micro-extraction coupled on-line to gas chromatography/mass spectrometry with in-liner derivatisation.

    PubMed

    Peters, Sonja; Kaal, Erwin; Horsting, Iwan; Janssen, Hans-Gerd

    2012-02-24

    A new method is presented for the analysis of phenolic acids in plasma based on ion-pairing 'Micro-extraction in packed sorbent' (MEPS) coupled on-line to in-liner derivatisation-gas chromatography-mass spectrometry (GC-MS). The ion-pairing reagent served a dual purpose. It was used both to improve extraction yields of the more polar analytes and as the methyl donor in the automated in-liner derivatisation method. In this way, a fully automated procedure for the extraction, derivatisation and injection of a wide range of phenolic acids in plasma samples has been obtained. An extensive optimisation of the extraction and derivatisation procedure has been performed. The entire method showed excellent repeatabilities of under 10% and linearities of 0.99 or better for all phenolic acids. The limits of detection of the optimised method for the majority of phenolic acids were 10ng/mL or lower with three phenolic acids having less-favourable detection limits of around 100 ng/mL. Finally, the newly developed method has been applied in a human intervention trial in which the bioavailability of polyphenols from wine and tea was studied. Forty plasma samples could be analysed within 24h in a fully automated method including sample extraction, derivatisation and gas chromatographic analysis. Copyright © 2011 Elsevier B.V. All rights reserved.

  3. Plasma levels of miRNA-155 as a powerful diagnostic marker for dedifferentiated liposarcoma

    PubMed Central

    Boro, Aleksandar; Bauer, David; Born, Walter; Fuchs, Bruno

    2016-01-01

    Atypic lipomatous tumors (ALT) and dedifferentiated liposarcomas (DDLS) are closely related liposarcoma subtypes, often difficult to distinguish but they exhibit an entirely different clinical outcome. Recently discovered regulatory functions of miRNAs in liposarcoma progression prompted us to investigate miRNAs as potential diagnostic biomarkers in liposarcoma with a main focus on circulating miRNAs for fast and reliable differential diagnosis. Tumor and blood samples of 35 patients with lipomatous lesions collected between June 2011 and September 2014 were analyzed by qRT-PCR. They included 10 lipomas, 7 ALT, 5 DDLS and 13 myxoid liposarcomas (MLS). Ten samples of normal fat tissue and blood from 20 healthy volunteers were used as controls. A meta-analysis of public data on miRNA expression in liposarcoma revealed 9 miRNAs with potential diagnostic power. Out of these, miRNA-155 was found significantly elevated in the circulation of DDLS patients as compared to the plasma levels detected in all other liposarcoma subtypes and in healthy subjects. miRNA-155 levels in the plasma samples correlated significantly (r=0.41, p=0.02) with those in corresponding tumor extracts. This correlation was even more pronounced in an analysis of plasma and tumor extracts of malignant liposarcoma subtypes alone (r=0.51, p=0.02). Receiver operating characteristic analysis indicated that plasma miRNA-155 levels have a high diagnostic accuracy for distinguishing DDLS from healthy subjects (AUC=0.91, p=0.005) and from lipomas (AUC=0.86, p=0.02), MLS (AUC=0.92, p=0.006) and most importantly ALT (AUC=0.91, p=0.01) patients. In conclusion, this study identified miRNA-155 as a first blood biomarker for the differential diagnosis of DDLS. PMID:27186423

  4. Doping control analysis of 46 polar drugs in horse plasma and urine using a 'dilute-and-shoot' ultra high performance liquid chromatography-high resolution mass spectrometry approach.

    PubMed

    Kwok, Wai Him; Choi, Timmy L S; Kwok, Karen Y; Chan, George H M; Wong, Jenny K Y; Wan, Terence S M

    2016-06-17

    The high sensitivity of ultra high performance liquid chromatography coupled with high resolution mass spectrometry (UHPLC-HRMS) allows the identification of many prohibited substances without pre-concentration, leading to the development of simple and fast 'dilute-and-shoot' methods for doping control for human and equine sports. While the detection of polar drugs in plasma and urine is difficult using liquid-liquid or solid-phase extraction as these substances are poorly extracted, the 'dilute-and-shoot' approach is plausible. This paper describes a 'dilute-and-shoot' UHPLC-HRMS screening method to detect 46 polar drugs in equine urine and plasma, including some angiotensin-converting enzyme (ACE) inhibitors, sympathomimetics, anti-epileptics, hemostatics, the new doping agent 5-aminoimidazole-4-carboxamide-1-β-d-ribofuranoside (AICAR), as well as two threshold substances, namely dimethyl sulfoxide and theobromine. For plasma, the sample (200μL) was protein precipitated using trichloroacetic acid, and the resulting supernatant was diluted using Buffer A with an overall dilution factor of 3. For urine, the sample (20μL) was simply diluted 50-fold with Buffer A. The diluted plasma or urine sample was then analysed using a UHPLC-HRMS system in full-scan ESI mode. The assay was validated for qualitative identification purpose. This straightforward and reliable approach carried out in combination with other screening procedures has increased the efficiency of doping control analysis in the laboratory. Moreover, since the UHPLC-HRMS data were acquired in full-scan mode, the method could theoretically accommodate an unlimited number of existing and new doping agents, and would allow a retrospectively search for drugs that have not been targeted at the time of analysis. Copyright © 2016 Elsevier B.V. All rights reserved.

  5. Quantification of drugs in plasma without primary reference standards by liquid chromatography-chemiluminescence nitrogen detection: application to tramadol metabolite ratios.

    PubMed

    Ojanperä, Suvi; Rasanen, Ilpo; Sistonen, Johanna; Pelander, Anna; Vuori, Erkki; Ojanperä, Ilkka

    2007-08-01

    Lack of availability of reference standards for drug metabolites, newly released drugs, and illicit drugs hinders the analysis of these substances in biologic samples. To counter this problem, an approach is presented here for quantitative drug analysis in plasma without primary reference standards by liquid chromatography-chemiluminescence nitrogen detection (LC-CLND). To demonstrate the feasibility of the method, metabolic ratios of the opioid drug tramadol were determined in the setting of a pharmacogenetic study. Four volunteers were given a single 100-mg oral dose of tramadol, and a blood sample was collected from each subject 1 hour later. Tramadol, O-desmethyltramadol, and nortramadol were determined in plasma by LC-CLND without reference standards and by a gas chromatography-mass spectrometry reference method. In contrast to previous CLND studies lacking an extraction step, a liquid-liquid extraction system was created for 5-mL plasma samples using n-butyl chloride-isopropyl alcohol (98 + 2) at pH 10. Extraction recovery estimation was based on model compounds chosen according to their similar physicochemical characteristics (retention time, pKa, logD). Instrument calibration was performed with a single secondary standard (caffeine) using the equimolar response of the detector to nitrogen. The mean differences between the results of the LC-CLND and gas chromatography-mass spectrometry methods for tramadol, O-desmethyltramadol, and nortramadol were 8%, 32%, and 19%, respectively. The sensitivity of LC-CLND was sufficient for therapeutic concentrations of tramadol and metabolites. A good correlation was obtained between genotype, expressed by the number of functional genes, and the plasma metabolite ratios. This experiment suggests that a recovery-corrected LC-CLND analysis produces sufficiently accurate results to be useful in a clinical context, particularly in instances in which reference standards are not readily accessible.

  6. Characterization of atmospheric pressure plasma treated wool/cashmere textiles: Treatment in nitrogen

    NASA Astrophysics Data System (ADS)

    Zanini, Stefano; Citterio, Attilio; Leonardi, Gabriella; Riccardi, Claudia

    2018-01-01

    We performed atmospheric pressure plasma treatments of wool/cashmere (15/85%) textiles with a dielectric barrier discharge (DBD) in nitrogen. The chemical properties of the plasma treated samples were investigated with attenuated total reflectance Fourier transform infrared (FTIR/ATR) spectroscopy, X-ray photoelectron microscopy (XPS), and fatty acid gas chromatographic analysis. Changes in mechanical properties and tactile performance of textiles after the plasma treatment were determined using the KES-F system. The analyses reveal significant surface modification of the treated fabrics, which enhances their surface wettability.

  7. An integrated bioanalytical method development and validation approach: case studies.

    PubMed

    Xue, Y-J; Melo, Brian; Vallejo, Martha; Zhao, Yuwen; Tang, Lina; Chen, Yuan-Shek; Keller, Karin M

    2012-10-01

    We proposed an integrated bioanalytical method development and validation approach: (1) method screening based on analyte's physicochemical properties and metabolism information to determine the most appropriate extraction/analysis conditions; (2) preliminary stability evaluation using both quality control and incurred samples to establish sample collection, storage and processing conditions; (3) mock validation to examine method accuracy and precision and incurred sample reproducibility; and (4) method validation to confirm the results obtained during method development. This integrated approach was applied to the determination of compound I in rat plasma and compound II in rat and dog plasma. The effectiveness of the approach was demonstrated by the superior quality of three method validations: (1) a zero run failure rate; (2) >93% of quality control results within 10% of nominal values; and (3) 99% incurred sample within 9.2% of the original values. In addition, rat and dog plasma methods for compound II were successfully applied to analyze more than 900 plasma samples obtained from Investigational New Drug (IND) toxicology studies in rats and dogs with near perfect results: (1) a zero run failure rate; (2) excellent accuracy and precision for standards and quality controls; and (3) 98% incurred samples within 15% of the original values. Copyright © 2011 John Wiley & Sons, Ltd.

  8. A Comprehensive Software and Database Management System for Glomerular Filtration Rate Estimation by Radionuclide Plasma Sampling and Serum Creatinine Methods.

    PubMed

    Jha, Ashish Kumar

    2015-01-01

    Glomerular filtration rate (GFR) estimation by plasma sampling method is considered as the gold standard. However, this method is not widely used because the complex technique and cumbersome calculations coupled with the lack of availability of user-friendly software. The routinely used Serum Creatinine method (SrCrM) of GFR estimation also requires the use of online calculators which cannot be used without internet access. We have developed user-friendly software "GFR estimation software" which gives the options to estimate GFR by plasma sampling method as well as SrCrM. We have used Microsoft Windows(®) as operating system and Visual Basic 6.0 as the front end and Microsoft Access(®) as database tool to develop this software. We have used Russell's formula for GFR calculation by plasma sampling method. GFR calculations using serum creatinine have been done using MIRD, Cockcroft-Gault method, Schwartz method, and Counahan-Barratt methods. The developed software is performing mathematical calculations correctly and is user-friendly. This software also enables storage and easy retrieval of the raw data, patient's information and calculated GFR for further processing and comparison. This is user-friendly software to calculate the GFR by various plasma sampling method and blood parameter. This software is also a good system for storing the raw and processed data for future analysis.

  9. Appropriate Handling, Processing and Analysis of Blood Samples Is Essential to Avoid Oxidation of Vitamin C to Dehydroascorbic Acid

    PubMed Central

    Pullar, Juliet M.; Carr, Anitra C.

    2018-01-01

    Vitamin C (ascorbate) is the major water-soluble antioxidant in plasma and its oxidation to dehydroascorbic acid (DHA) has been proposed as a marker of oxidative stress in vivo. However, controversy exists in the literature around the amount of DHA detected in blood samples collected from various patient cohorts. In this study, we report on DHA concentrations in a selection of different clinical cohorts (diabetes, pneumonia, cancer, and critically ill). All clinical samples were collected into EDTA anticoagulant tubes and processed at 4 °C prior to storage at −80 °C for subsequent analysis by HPLC with electrochemical detection. We also investigated the effects of different handling and processing conditions on short-term and long-term ascorbate and DHA stability in vitro and in whole blood and plasma samples. These conditions included metal chelation, anticoagulants (EDTA and heparin), and processing temperatures (ice, 4 °C and room temperature). Analysis of our clinical cohorts indicated very low to negligible DHA concentrations. Samples exhibiting haemolysis contained significantly higher concentrations of DHA. Metal chelation inhibited oxidation of vitamin C in vitro, confirming the involvement of contaminating metal ions. Although EDTA is an effective metal chelator, complexes with transition metal ions are still redox active, thus its use as an anticoagulant can facilitate metal ion-dependent oxidation of vitamin C in whole blood and plasma. Handling and processing blood samples on ice (or at 4 °C) delayed oxidation of vitamin C by a number of hours. A review of the literature regarding DHA concentrations in clinical cohorts highlighted the fact that studies using colourimetric or fluorometric assays reported significantly higher concentrations of DHA compared to those using HPLC with electrochemical detection. In conclusion, careful handling and processing of samples, combined with appropriate analysis, is crucial for accurate determination of ascorbate and DHA in clinical samples. PMID:29439480

  10. Analysis of indium zinc oxide thin films by laser-induced breakdown spectroscopy

    NASA Astrophysics Data System (ADS)

    Popescu, A. C.; Beldjilali, S.; Socol, G.; Craciun, V.; Mihailescu, I. N.; Hermann, J.

    2011-10-01

    We have performed spectroscopic analysis of the plasma generated by Nd:YAG (λ = 266 nm) laser irradiation of thin indium zinc oxide films with variable In content deposited by combinatorial pulsed laser deposition on glass substrates. The samples were irradiated in 5 × 104 Pa argon using laser pulses of 5 ns duration and 10 mJ energy. The plasma emission spectra were recorded with an Echelle spectrometer coupled to a gated detector with different delays with respect to the laser pulse. The relative concentrations of indium and zinc were evaluated by comparing the measured spectra to the spectral radiance computed for a plasma in local thermal equilibrium. Plasma temperature and electron density were deduced from the relative intensities and Stark broadening of spectral lines of atomic zinc. Analyses at different locations on the deposited thin films revealed that the In/(In + Zn) concentration ratio significantly varies over the sample surface, from 0.4 at the borders to about 0.5 in the center of the film. The results demonstrate that laser-induced breakdown spectroscopy allows for precise and fast characterization of thin films with variable composition.

  11. Microplasmas for chemical analysis: analytical tools or research toys?

    NASA Astrophysics Data System (ADS)

    Karanassios, Vassili

    2004-07-01

    An overview of the activities of the research groups that have been involved in fabrication, development and characterization of microplasmas for chemical analysis over the last few years is presented. Microplasmas covered include: miniature inductively coupled plasmas (ICPs); capacitively coupled plasmas (CCPs); microwave-induced plasmas (MIPs); a dielectric barrier discharge (DBD); microhollow cathode discharge (MCHD) or microstructure electrode (MSE) discharges, other microglow discharges (such as those formed between "liquid" electrodes); microplasmas formed in micrometer-diameter capillary tubes for gas chromatography (GC) or high-performance liquid chromatography (HPLC) applications, and a stabilized capacitive plasma (SCP) for GC applications. Sample introduction into microplasmas, in particular, into a microplasma device (MPD), battery operation of a MPD and of a mini- in-torch vaporization (ITV) microsample introduction system for MPDs, and questions of microplasma portability for use on site (e.g., in the field) are also briefly addressed using examples of current research. To emphasize the significance of sample introduction into microplasmas, some previously unpublished results from the author's laboratory have also been included. And an overall assessment of the state-of-the-art of analytical microplasma research is provided.

  12. Influence of absorbed moisture on desizing of poly(vinyl alcohol) on cotton fabrics during atmospheric pressure plasma jet treatment

    NASA Astrophysics Data System (ADS)

    Peng, Shujing; Liu, Xiulan; Sun, Jie; Gao, Zhiqiang; Yao, Lan; Qiu, Yiping

    2010-04-01

    This paper studies the influence of moisture absorption of cotton fabrics on the effectiveness of atmospheric pressure plasma jet (APPJ) on desizing of polyvinyl alcohol (PVA). Cotton fabrics with three different moisture regains (MR), namely 1.8%, 7.3%, and 28.4% corresponding to 10%, 65%, and 98% of relative humidity respectively, are treated for 16 s, 32 s, 48 s, and 64 s. X-ray photoelectron spectroscopy analysis indicates that the plasma treated PVA has higher oxygen concentration than the control. Mass loss results show that the fabric with the highest MR has the largest mass loss after 64 s plasma exposure. Solubility measurement reveals that the sample with the lowest MR has the highest desizing efficacy and the percent desizing ratio reaches 96% after 64 s exposure plus a 20 min hot wash, which is shown as clean as the unsized sample through scanning electron microscopy analysis. The yarn tensile strength test results show that APPJ has no negative effect on fabric tensile strength.

  13. Tracing and separating plasma components causing matrix effects in hydrophilic interaction chromatography-electrospray ionization mass spectrometry.

    PubMed

    Ekdahl, Anja; Johansson, Maria C; Ahnoff, Martin

    2013-04-01

    Matrix effects on electrospray ionization were investigated for plasma samples analysed by hydrophilic interaction chromatography (HILIC) in gradient elution mode, and HILIC columns of different chemistries were tested for separation of plasma components and model analytes. By combining mass spectral data with post-column infusion traces, the following components of protein-precipitated plasma were identified and found to have significant effect on ionization: urea, creatinine, phosphocholine, lysophosphocholine, sphingomyelin, sodium ion, chloride ion, choline and proline betaine. The observed effect on ionization was both matrix-component and analyte dependent. The separation of identified plasma components and model analytes on eight columns was compared, using pair-wise linear correlation analysis and principal component analysis (PCA). Large changes in selectivity could be obtained by change of column, while smaller changes were seen when the mobile phase buffer was changed from ammonium formate pH 3.0 to ammonium acetate pH 4.5. While results from PCA and linear correlation analysis were largely in accord, linear correlation analysis was judged to be more straight-forward in terms of conduction and interpretation.

  14. A comparative bear model for immobility-induced osteopenia

    NASA Technical Reports Server (NTRS)

    Milbury, P. E.; Vaughan, M. R.; Farley, S.; Matula, G. J. Jr; Convertino, V. A.; Matson, W. R.

    1998-01-01

    The National Institutes of Health (NIH) and the National Aeronautics and Space Administration (NASA) are seeking solutions to the human problem of osteopenia, or immobility-induced bone loss. Bears, during winter dormancy, appear uniquely exempted from the debilitating effects of immobility osteopenia. NIH and ESA, Inc. are creating a large database of metabolic information on human ambulatory and bedrest plasma samples for comparison with metabolic data obtained from bear plasma samples collected in different seasons. The database generated from NASA's HR113 human bedrest study showed a clear difference between plasma samples of ambulatory and immobile subjects through cluster analysis using compounds determined by high performance liquid chromatography with coulometric electrochemical array detection (HPLC-EC). We collected plasma samples from black bears (Ursus americanus) across 4 seasons and from 3 areas and subjected them to similar analysis, with particular attention to compounds that changed significantly in the NASA human study. We found seasonal differences in 28 known compounds and 33 unknown compounds. A final database contained 40 known and 120 unknown peaks that were reliably assayed in all bear and human samples; these were the primary data set for interspecies comparison. Six unidentified compounds changed significantly but differentially in wintering bears and immobile humans. The data are discussed in light of current theories regarding dormancy, starvation, and anabolic metabolism. Work is in progress by ESA Laboratories on a larger database to confirm these findings prior to a chemical isolation and identification effort. This research could lead to new pharmaceuticals or dietary interventions for the treatment of immobility osteopenia.

  15. Oxidation behaviour of Fe-Ni alloy nanoparticles synthesized by thermal plasma route

    NASA Astrophysics Data System (ADS)

    Ghodke, Neha; Kamble, Shalaka; Raut, Suyog; Puranik, Shridhar; Bhoraskar, S. V.; Rayaprol, Sudhindra; Mathe, V. L.

    2018-04-01

    Here we report synthesis of Fe-Ni nanoparticles using thermal plasma route. In thermal plasma, gas phase nucleation and growth at sufficiently higher temperature is observed. The synthesized Fe-Ni nanoparticles are examined by X-ray Diffraction, Raman Spectroscopy, Vibrating Sample Magnetometer and Thermo gravimetric Analysis. Formation of 16-21 nm sized Fe-Ni nanoparticles having surface oxidation show maximum value of magnetization of ˜107 emu/g. The sample synthesized at relatively low power (4kW) show presence of carbonaceous species whereas the high power (6 kW) synthesis does not depicts carbonaceous species. The presence of carbonaceous species protects oxidation of the nanoparticles significantly as evidenced from TGA data.

  16. Longitudinal monitoring of EGFR mutations in plasma predicts outcomes of NSCLC patients treated with EGFR TKIs: Korean Lung Cancer Consortium (KLCC-12-02).

    PubMed

    Lee, Ji Yun; Qing, Xu; Xiumin, Wei; Yali, Bai; Chi, Sangah; Bak, So Hyeon; Lee, Ho Yun; Sun, Jong-Mu; Lee, Se-Hoon; Ahn, Jin Seok; Cho, Eun Kyung; Kim, Dong-Wan; Kim, Hye Ryun; Min, Young Joo; Jung, Sin-Ho; Park, Keunchil; Mao, Mao; Ahn, Myung-Ju

    2016-02-09

    We hypothesized that plasma-based EGFR mutation analysis for NSCLC may be feasible for monitoring treatment response to EGFR TKIs and also predict drug resistance.Clinically relevant mutations including exon 19 deletion (ex19del), L858R and T790M were analyzed using droplet digital PCR (ddPCR) in longitudinally collected plasma samples (n = 367) from 81 NSCLC patients treated with EGFR TKI. Of a total 58 baseline cell-free DNA (cfDNA) samples available for ddPCR analysis, 43 (74.1%) had the same mutation in the matched tumors (clinical sensitivity: 70.8% [17/24] for L858R and 76.5% [26/34] for ex19del). The concordance rates of plasma with tissue-based results of EGFR mutations were 87.9% for L858R and 86.2% for ex19del. All 40 patients who were detected EGFR mutations at baseline showed a dramatic decrease of mutant copies (>50%) in plasma during the first two months after treatment. Median progression-free survival (PFS) was 10.1 months for patients with undetectable EGFR v 6.3 months for detectable EGFR mutations in blood after two-month treatment (HR 3.88, 95% CI 1.48-10.19, P = 0.006). We observed emerging resistance with early detection of T790M as a secondary mutation in 14 (28.6%) of 49 patients. Plasma-based EGFR mutation analysis using ddPCR can monitor treatment response to EGFR TKIs and can lead to early detection of EGFR TKIs resistance. Further studies confirming clinical implications of EGFR mutation in plasma are warranted to guide optimal therapeutic strategies upon knowledge of treatment response and resistance.

  17. Comparative study of Nd:YAG laser-induced breakdown spectroscopy and transversely excited atmospheric CO2 laser-induced gas plasma spectroscopy on chromated copper arsenate preservative-treated wood.

    PubMed

    Khumaeni, Ali; Lie, Zener Sukra; Niki, Hideaki; Lee, Yong Inn; Kurihara, Kazuyoshi; Wakasugi, Motoomi; Takahashi, Touru; Kagawa, Kiichiro

    2012-03-01

    Taking advantage of the specific characteristics of a transversely excited atmospheric (TEA) CO(2) laser, a sophisticated technique for the analysis of chromated copper arsenate (CCA) in wood samples has been developed. In this study, a CCA-treated wood sample with a dimension of 20 mm × 20 mm and a thickness of 2 mm was attached in contact to a nickel plate (20 mm × 20 mm × 0.15 mm), which functions as a subtarget. When the TEA CO(2) laser was successively irradiated onto the wood surface, a hole with a diameter of approximately 2.5 mm was produced inside the sample and the laser beam was directly impinged onto the metal subtarget. Strong and stable gas plasma with a very large diameter of approximately 10 mm was induced once the laser beam had directly struck the metal subtarget. This gas plasma then interacted with the fine particles of the sample inside the hole and finally the particles were effectively dissociated and excited in the gas plasma region. By using this technique, high precision and sensitive analysis of CCA-treated wood sample was realized. A linear calibration curve of Cr was successfully made using the CCA-treated wood sample. The detection limits of Cr, Cu, and As were estimated to be approximately 1, 2, and 15 mg/kg, respectively. In the case of standard LIBS using the Nd:YAG laser, the analytical intensities fluctuate and the detection limit was much lower at approximately one-tenth that of TEA CO(2) laser. © 2012 Optical Society of America

  18. Comparison of Standardized Cytomegalovirus (CMV) Viral Load Thresholds in Whole Blood and Plasma of Solid Organ and Hematopoietic Stem Cell Transplant Recipients with CMV Infection and Disease.

    PubMed

    Dioverti, M Veronica; Lahr, Brian D; Germer, Jeffrey J; Yao, Joseph D; Gartner, Michelle L; Razonable, Raymund R

    2017-01-01

    Quantification of cytomegalovirus (CMV) deoxyribonucleic acid (DNA) has important diagnostic, prognostic, and therapeutic implications in the management of transplant recipients. We aimed to assess a viral load in plasma and whole blood that distinguishes CMV disease from asymptomatic infection in a cohort of solid organ and hematopoietic stem cell transplantation. We prospectively measured and compared CMV viral load in paired plasma and whole blood samples collected from transplant recipients with CMV infection and disease. Cytomegalovirus viral loads were determined by a commercially available US Food and Drug Administration-approved quantitative assay (COBAS AmpliPrep/COBAS TaqMan CMV Test [CAP/CTM CMV]) calibrated to the first World Health Organization International Standard for CMV DNA quantification. Moderate agreement of CMV viral load was observed between plasma and whole blood, with 31% of samples having discordant findings, particularly among samples with low DNA levels. Among the subset of samples where both paired samples had quantifiable levels, we observed a systematic bias that reflected higher viral load in whole blood compared with plasma. Based on receiver operating curve analysis, an initial plasma CMV viral load threshold of 1700 IU/mL in solid organ transplant recipients (sensitivity 80%, specificity 74%) and 1350 IU/mL in allogeneic hematopoietic stem cell transplant recipients (sensitivity 87%, specificity 87%) distinguished CMV disease and asymptomatic infection. This study identifies standardized viral load thresholds that distinguish CMV disease from asymptomatic infection using CAP/CTM CMV assay. We propose these thresholds as potential triggers to be evaluated in prospective studies of preemptive therapy. Plasma was better than whole blood for measuring viral load using the CAP/CTM CMV assay.

  19. Plasma metabolomics reveals membrane lipids, aspartate/asparagine and nucleotide metabolism pathway differences associated with chloroquine resistance in Plasmodium vivax malaria

    PubMed Central

    Salinas, Jorge L.; Monteiro, Wuelton M.; Val, Fernando; Cordy, Regina J.; Liu, Ken; Melo, Gisely C.; Siqueira, Andre M.; Magalhaes, Belisa; Galinski, Mary R.; Lacerda, Marcus V. G.; Jones, Dean P.

    2017-01-01

    Background Chloroquine (CQ) is the main anti-schizontocidal drug used in the treatment of uncomplicated malaria caused by Plasmodium vivax. Chloroquine resistant P. vivax (PvCR) malaria in the Western Pacific region, Asia and in the Americas indicates a need for biomarkers of resistance to improve therapy and enhance understanding of the mechanisms associated with PvCR. In this study, we compared plasma metabolic profiles of P. vivax malaria patients with PvCR and chloroquine sensitive parasites before treatment to identify potential molecular markers of chloroquine resistance. Methods An untargeted high-resolution metabolomics analysis was performed on plasma samples collected in a malaria clinic in Manaus, Brazil. Male and female patients with Plasmodium vivax were included (n = 46); samples were collected before CQ treatment and followed for 28 days to determine PvCR, defined as the recurrence of parasitemia with detectable plasma concentrations of CQ ≥100 ng/dL. Differentially expressed metabolic features between CQ-Resistant (CQ-R) and CQ-Sensitive (CQ-S) patients were identified using partial least squares discriminant analysis and linear regression after adjusting for covariates and multiple testing correction. Pathway enrichment analysis was performed using Mummichog. Results Linear regression and PLS-DA methods yielded 69 discriminatory features between CQ-R and CQ-S groups, with 10-fold cross-validation classification accuracy of 89.6% using a SVM classifier. Pathway enrichment analysis showed significant enrichment (p<0.05) of glycerophospholipid metabolism, glycosphingolipid metabolism, aspartate and asparagine metabolism, purine and pyrimidine metabolism, and xenobiotics metabolism. Glycerophosphocholines levels were significantly lower in the CQ-R group as compared to CQ-S patients and also to independent control samples. Conclusions The results show differences in lipid, amino acids, and nucleotide metabolism pathways in the plasma of CQ-R versus CQ-S patients prior to antimalarial treatment. Metabolomics phenotyping of P. vivax samples from patients with well-defined clinical CQ-resistance is promising for the development of new tools to understand the biological process and to identify potential biomarkers of PvCR. PMID:28813452

  20. A 96-well screen filter plate for high-throughput biological sample preparation and LC-MS/MS analysis.

    PubMed

    Peng, Sean X; Cousineau, Martin; Juzwin, Stephen J; Ritchie, David M

    2006-01-01

    A novel 96-well screen filter plate (patent pending) has been invented to eliminate a time-consuming and labor-intensive step in preparation of in vivo study samples--to remove blood or plasma clots. These clots plug the pipet tips during a manual or automated sample-transfer step causing inaccurate pipetting or total pipetting failure. Traditionally, these blood and plasma clots are removed by picking them out manually one by one from each sample tube before any sample transfer can be made. This has significantly slowed the sample preparation process and has become a bottleneck for automated high-throughput sample preparation using robotic liquid handlers. Our novel screen filter plate was developed to solve this problem. The 96-well screen filter plate consists of 96 stainless steel wire-mesh screen tubes connected to the 96 openings of a top plate so that the screen filter plate can be readily inserted into a 96-well sample storage plate. Upon insertion, the blood and plasma clots are excluded from entering the screen tube while clear sample solutions flow freely into it. In this way, sample transfer can be easily completed by either manual or automated pipetting methods. In this report, three structurally diverse compounds were selected to evaluate and validate the use of the screen filter plate. The plasma samples of these compounds were transferred and processed in the presence and absence of the screen filter plate and then analyzed by LC-MS/MS methods. Our results showed a good agreement between the samples prepared with and without the screen filter plate, demonstrating the utility and efficiency of this novel device for preparation of blood and plasma samples. The device is simple, easy to use, and reusable. It can be employed for sample preparation of other biological fluids that contain floating particulates or aggregates.

  1. Inductively Coupled Plasma Optical Emission Spectrometry for Rare Earth Elements Analysis

    NASA Astrophysics Data System (ADS)

    He, Man; Hu, Bin; Chen, Beibei; Jiang, Zucheng

    2017-01-01

    Inductively coupled plasma optical emission spectrometry (ICP-OES) merits multielements capability, high sensitivity, good reproducibility, low matrix effect and wide dynamic linear range for rare earth elements (REEs) analysis. But the spectral interference in trace REEs analysis by ICP-OES is a serious problem due to the complicated emission spectra of REEs, which demands some correction technology including interference factor method, derivative spectrum, Kalman filtering algorithm and partial least-squares (PLS) method. Matrix-matching calibration, internal standard, correction factor and sample dilution are usually employed to overcome or decrease the matrix effect. Coupled with various sample introduction techniques, the analytical performance of ICP-OES for REEs analysis would be improved. Compared with conventional pneumatic nebulization (PN), acid effect and matrix effect are decreased to some extent in flow injection ICP-OES, with higher tolerable matrix concentration and better reproducibility. By using electrothermal vaporization as sample introduction system, direct analysis of solid samples by ICP-OES is achieved and the vaporization behavior of refractory REEs with high boiling point, which can easily form involatile carbides in the graphite tube, could be improved by using chemical modifier, such as polytetrafluoroethylene and 1-phenyl-3-methyl-4-benzoyl-5-pyrazone. Laser ablation-ICP-OES is suitable for the analysis of both conductive and nonconductive solid samples, with the absolute detection limit of ng-pg level and extremely low sample consumption (0.2 % of that in conventional PN introduction). ICP-OES has been extensively employed for trace REEs analysis in high-purity materials, and environmental and biological samples.

  2. Lipidomic analysis of biological samples: Comparison of liquid chromatography, supercritical fluid chromatography and direct infusion mass spectrometry methods.

    PubMed

    Lísa, Miroslav; Cífková, Eva; Khalikova, Maria; Ovčačíková, Magdaléna; Holčapek, Michal

    2017-11-24

    Lipidomic analysis of biological samples in a clinical research represents challenging task for analytical methods given by the large number of samples and their extreme complexity. In this work, we compare direct infusion (DI) and chromatography - mass spectrometry (MS) lipidomic approaches represented by three analytical methods in terms of comprehensiveness, sample throughput, and validation results for the lipidomic analysis of biological samples represented by tumor tissue, surrounding normal tissue, plasma, and erythrocytes of kidney cancer patients. Methods are compared in one laboratory using the identical analytical protocol to ensure comparable conditions. Ultrahigh-performance liquid chromatography/MS (UHPLC/MS) method in hydrophilic interaction liquid chromatography mode and DI-MS method are used for this comparison as the most widely used methods for the lipidomic analysis together with ultrahigh-performance supercritical fluid chromatography/MS (UHPSFC/MS) method showing promising results in metabolomics analyses. The nontargeted analysis of pooled samples is performed using all tested methods and 610 lipid species within 23 lipid classes are identified. DI method provides the most comprehensive results due to identification of some polar lipid classes, which are not identified by UHPLC and UHPSFC methods. On the other hand, UHPSFC method provides an excellent sensitivity for less polar lipid classes and the highest sample throughput within 10min method time. The sample consumption of DI method is 125 times higher than for other methods, while only 40μL of organic solvent is used for one sample analysis compared to 3.5mL and 4.9mL in case of UHPLC and UHPSFC methods, respectively. Methods are validated for the quantitative lipidomic analysis of plasma samples with one internal standard for each lipid class. Results show applicability of all tested methods for the lipidomic analysis of biological samples depending on the analysis requirements. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. MicroRNA-6826 and -6875 in plasma are valuable non‑invasive biomarkers that predict the efficacy of vaccine treatment against metastatic colorectal cancer.

    PubMed

    Kijima, Taiki; Hazama, Shoichi; Tsunedomi, Ryouichi; Tanaka, Hironori; Takenouchi, Hiroko; Kanekiyo, Shinsuke; Inoue, Yuka; Nakashima, Masao; Iida, Michihisa; Sakamoto, Kazuhiko; Suzuki, Nobuaki; Takeda, Shigeru; Ueno, Tomio; Yamamoto, Shigeru; Yoshino, Shigefumi; Okuno, Kiyotaka; Nagano, Hiroaki

    2017-01-01

    Various vaccine treatments against metastatic colorectal cancer have been developed and applied. However, to improve the efficacy of immunotherapy, biomarkers that can predict the effects are needed. It has been reported that various microRNAs (miRNAs) in peripheral blood may be useful as non-invasive biomarkers. In this study, miRNAs influencing the efficacy of vaccine treatment were screened for in a microarray analysis of 13 plasma samples that were obtained from patients prior to vaccine treatment. To validate the screening results, real-time RT-PCR was performed using 93 plasma samples obtained from patients prior to vaccine treatment. Four candidate miRNAs were selected according to the results of the comprehensive analysis of miRNA expression, which were ranked using the Fisher criterion and the absolute value of the log2 ratio in the screening analysis. The validation analysis showed that in the HLA-A*2402‑matched patient group (vaccine-treated group), patients with a high expression of plasma miR-6826 had a poorer prognosis than those with a low expression (P=0.048). In contrast, in the HLA-A*2402-unmatched patient group (control group), there was no difference between the patients with high or low plasma miR-6826 expression (P=0.168). Similar results were obtained in the analysis of miR-6875 (P=0.029 and P=0.754, respectively). Moreover, multivariate analysis of the Cox regression model indicated that the expression of miR-6826 was the most significant predictor for overall survival (P=0.003, hazard ratio, 3.670). In conclusion, plasma miR-6826 and miR-6875 may be predictive biomarkers for a poor response to vaccine treatment. Although further clarification is needed regarding the functions of miR-6826 and miR-6875 and their relationship to immune‑related molecules, plasma miR-6826 and miR-6875 may be useful negative biomarkers for predicting the efficacy of vaccine treatment.

  4. Dielectric barrier discharge and jet type plasma surface modifications of hybrid polymeric poly (ε-caprolactone)/chitosan scaffolds.

    PubMed

    Ozkan, Ozan; Turkoglu Sasmazel, Hilal

    2018-04-01

    In this study, dry air plasma jet and dielectric barrier discharge Ar + O 2 or Ar + N 2 plasma modifications and their effects on wettability, topography, functionality and biological efficiency of the hybrid polymeric poly (ε-caprolactone)/chitosan scaffolds were reported. The samples treated with Ar + O 2 dielectric barrier discharge plasma (80 sccm O 2 flow rate, 3-min treatment) or with dry air plasma jet (15-cm nozzle-sample distance, 13-min treatment) had the closest wettability (49.11 ± 1.83 and 53.60 ± 0.95, respectively) to the commercial tissue culture polystyrene used for cell cultivation. Scanning electron microscopy images and X-ray photoelectron spectrometry analysis showed increase in topographical roughness and OH/NH 2 functionality, respectively. Increased fluid uptake capacity for the scaffolds treated with Ar + O 2 dielectric barrier discharge plasma (73.60% ± 1.78) and dry air plasma jet (72.48% ± 0.75) were also noted. Finally, initial cell attachment as well as seven-day cell viability, growth and proliferation performances were found to be significantly better for both plasma treated scaffolds than for untreated scaffolds.

  5. Different exosome cargo from plasma/bronchoalveolar lavage in non-small-cell lung cancer.

    PubMed

    Rodríguez, Marta; Silva, Javier; López-Alfonso, Ana; López-Muñiz, María Belen; Peña, Cristina; Domínguez, Gemma; García, Jose Miguel; López-Gónzalez, Ana; Méndez, Miriam; Provencio, Mariano; García, Vanesa; Bonilla, Félix

    2014-09-01

    Tumor-derived exosomes mediate tumorigenesis by facilitating tumor growth, metastasis, development of drug resistance, and immunosuppression. However, little is known about the exosomes isolated from bronchoalveolar lavage (BAL) in patients with lung neoplasm. Exosomes isolated in plasma and BAL from 30 and 75 patients with tumor and nontumor pathology were quantified by acetylcholinesterase activity and characterized by Western Blot, Electron Microscopy, and Nanoparticle Tracking Analysis. Differences in exosome cargo were analyzed by miRNA quantitative PCR in pooled samples and validated in a second series of patients. More exosomes were detected in plasma than in BAL in both groups (P < 0.001). The most miRNAs evaluated by PCR array were detected in tumor plasma, tumor BAL, and nontumor BAL pools, but only 56% were detected in the nontumor plasma pool. Comparing the top miRNAs with the highest levels detected in each pool, we found close homology only between the BAL samples of the two pathologies. In tumor plasma, we found a higher percentage of miRNAs with increased levels than in tumor BAL or in nontumor plasma. The data reveal differences between BAL and plasma exosome amount and miRNA content. © 2014 Wiley Periodicals, Inc.

  6. Influence of tube type, storage time, and temperature on the total and free concentration of valproic acid.

    PubMed

    Tarasidis, C G; Garnett, W R; Kline, B J; Pellock, J M

    1986-01-01

    The influence of storage conditions on the total and free concentration of valproic acid (VPA) was studied in six normal male subjects who ingested 750 mg of VPA (3 X 250 mg Depakene capsules; Abbott Laboratories). Blood samples were collected in various types of Vacutainer tubes (red top, no additives; green top, sodium heparin; blue top, sodium citrate; and purple top, EDTA) 2 h post administration of VPA. Either these samples were centrifuged immediately or stored for various periods of time at room temperature or refrigerated, or the supernate was frozen prior to analysis. Free VPA samples were obtained utilizing the Amicon ultrafiltration system. All VPA samples were analyzed by gas-liquid chromatography. Total VPA concentrations obtained from plasma collected with sodium citrate were lower (p less than 0.05) than either serum or plasma collected with other anticoagulants. There were no differences (p greater than 0.05) in total or free VPA concentrations between samples collected in serum or in plasma collected with heparin or EDTA. Storing samples for 96 h at room temperature did not alter the total VPA concentrations but was found to increase the free fraction of VPA (p less than 0.05). The refrigeration or freezing of the supernate from the blood samples for 7 days did not alter (p greater than 0.05) the total or the free fraction of VPA. The results of this study demonstrate that total and/or free VPA may be collected from either serum or plasma, provided sodium citrate is not used to collect plasma.(ABSTRACT TRUNCATED AT 250 WORDS)

  7. Characterisation of the main drivers of intra- and inter- breed variability in the plasma metabolome of dogs.

    PubMed

    Lloyd, Amanda J; Beckmann, Manfred; Tailliart, Kathleen; Brown, Wendy Y; Draper, John; Allaway, David

    Dog breeds are a consequence of artificial selection for specific attributes. These closed genetic populations have metabolic and physiological characteristics that may be revealed by metabolomic analysis. To identify and characterise the drivers of metabolic differences in the fasted plasma metabolome and then determine metabolites differentiating breeds. Fasted plasma samples were collected from dogs maintained under two environmental conditions (controlled and client-owned at home). The former (n = 33) consisted of three breeds (Labrador Retriever, Cocker Spaniel and Miniature Schnauzer) fed a single diet batch, the latter (n = 96), client-owned dogs consisted of 9 breeds (Beagle, Chihuahua, Cocker Spaniel, Dachshund, Golden Retriever, Greyhound, German Shepherd, Labrador Retriever and Maltese) consuming various diets under differing feeding regimens. Triplicate samples were taken from Beagle (n = 10) and Labrador Retriever (n = 9) over 3 months. Non-targeted metabolite fingerprinting was performed using flow infusion electrospray-ionization mass spectrometry which was coupled with multivariate data analysis. Metadata factors including age, gender, sexual status, weight, diet and breed were investigated. Breed differences were identified in the plasma metabolome of dogs housed in a controlled environment. Triplicate samples from two breeds identified intra-individual variability, yet breed separation was still observed. The main drivers of variance in dogs maintained in the home environment were associated with breed and gender. Furthermore, metabolite signals were identified that discriminated between Labrador Retriever and Cocker Spaniels in both environments. Metabolite fingerprinting of plasma samples can be used to investigate breed differences in client-owned dogs, despite added variance of diet, sexual status and environment.

  8. A Calibration-Free Laser-Induced Breakdown Spectroscopy (CF-LIBS) Quantitative Analysis Method Based on the Auto-Selection of an Internal Reference Line and Optimized Estimation of Plasma Temperature.

    PubMed

    Yang, Jianhong; Li, Xiaomeng; Xu, Jinwu; Ma, Xianghong

    2018-01-01

    The quantitative analysis accuracy of calibration-free laser-induced breakdown spectroscopy (CF-LIBS) is severely affected by the self-absorption effect and estimation of plasma temperature. Herein, a CF-LIBS quantitative analysis method based on the auto-selection of internal reference line and the optimized estimation of plasma temperature is proposed. The internal reference line of each species is automatically selected from analytical lines by a programmable procedure through easily accessible parameters. Furthermore, the self-absorption effect of the internal reference line is considered during the correction procedure. To improve the analysis accuracy of CF-LIBS, the particle swarm optimization (PSO) algorithm is introduced to estimate the plasma temperature based on the calculation results from the Boltzmann plot. Thereafter, the species concentrations of a sample can be calculated according to the classical CF-LIBS method. A total of 15 certified alloy steel standard samples of known compositions and elemental weight percentages were used in the experiment. Using the proposed method, the average relative errors of Cr, Ni, and Fe calculated concentrations were 4.40%, 6.81%, and 2.29%, respectively. The quantitative results demonstrated an improvement compared with the classical CF-LIBS method and the promising potential of in situ and real-time application.

  9. Combined liquid chromatography-mass spectrometry for trace analysis of pharmaceuticals

    NASA Astrophysics Data System (ADS)

    Schmidt, Lothar; Danigel, Harald; Jungclas, Hartmut

    1982-07-01

    A 252Cf-plasma desorption mass spectrometer (PDMS) for the analysis of thin layers from nonvolatile organic samples has been set up to be combined with a liquid chromatograph. A novel interface performs the direct inlet of the liquid sample through a capillary into the vacuum system of the spectrometer. Samples of drugs are periodically collected, transferred to the ion source and analysed using a rotating disk. This on-line sample preparation has been tested for three antiarrhythmic drugs using various solvents and mixtures.

  10. On-line double isotope dilution laser ablation inductively coupled plasma mass spectrometry for the quantitative analysis of solid materials.

    PubMed

    Fernández, Beatriz; Rodríguez-González, Pablo; García Alonso, J Ignacio; Malherbe, Julien; García-Fonseca, Sergio; Pereiro, Rosario; Sanz-Medel, Alfredo

    2014-12-03

    We report on the determination of trace elements in solid samples by the combination of on-line double isotope dilution and laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS). The proposed method requires the sequential analysis of the sample and a certified natural abundance standard by on-line IDMS using the same isotopically-enriched spike solution. In this way, the mass fraction of the analyte in the sample can be directly referred to the certified standard so the previous characterization of the spike solution is not required. To validate the procedure, Sr, Rb and Pb were determined in certified reference materials with different matrices, including silicate glasses (SRM 610, 612 and 614) and powdered samples (PACS-2, SRM 2710a, SRM 1944, SRM 2702 and SRM 2780). The analysis of powdered samples was carried out both by the preparation of pressed pellets and by lithium borate fusion. Experimental results for the analysis of powdered samples were in agreement with the certified values for all materials. Relative standard deviations in the range of 6-21% for pressed pellets and 3-21% for fused solids were obtained from n=3 independent measurements. Minimal sample preparation, data treatment and consumption of the isotopically-enriched isotopes are the main advantages of the method over previously reported approaches. Copyright © 2014 Elsevier B.V. All rights reserved.

  11. Application of proteomics in the discovery of candidate protein biomarkers in a Diabetes Autoantibody Standardization Program (DASP) sample subset

    PubMed Central

    Metz, Thomas O.; Qian, Wei-Jun; Jacobs, Jon M.; Gritsenko, Marina A.; Moore, Ronald J.; Polpitiya, Ashoka D.; Monroe, Matthew E.; Camp, David G.; Mueller, Patricia W.; Smith, Richard D.

    2009-01-01

    Novel biomarkers of type 1 diabetes must be identified and validated in initial, exploratory studies before they can be assessed in proficiency evaluations. Currently, untargeted “-omics” approaches are under-utilized in profiling studies of clinical samples. This report describes the evaluation of capillary liquid chromatography (LC) coupled with mass spectrometry (MS) in a pilot proteomic analysis of human plasma and serum from a subset of control and type 1 diabetic individuals enrolled in the Diabetes Autoantibody Standardization Program with the goal of identifying candidate biomarkers of type 1 diabetes. Initial high-resolution capillary LC-MS/MS experiments were performed to augment an existing plasma peptide database, while subsequent LC-FTICR studies identified quantitative differences in the abundance of plasma proteins. Analysis of LC-FTICR proteomic data identified five candidate protein biomarkers of type 1 diabetes. Alpha-2-glycoprotein 1 (zinc), corticosteroid-binding globulin, and lumican were 2-fold up-regulated in type 1 diabetic samples relative to control samples, whereas clusterin and serotransferrin were 2-fold up-regulated in control samples relative to type 1 diabetic samples. Observed perturbations in the levels of all five proteins are consistent with the metabolic aberrations found in type 1 diabetes. While the discovery of these candidate protein biomarkers of type 1 diabetes is encouraging, follow up studies are required for validation in a larger population of individuals and for determination of laboratory-defined sensitivity and specificity values using blinded samples. PMID:18092746

  12. Application of proteomics in the discovery of candidate protein biomarkers in a diabetes autoantibody standardization program sample subset.

    PubMed

    Metz, Thomas O; Qian, Wei-Jun; Jacobs, Jon M; Gritsenko, Marina A; Moore, Ronald J; Polpitiya, Ashoka D; Monroe, Matthew E; Camp, David G; Mueller, Patricia W; Smith, Richard D

    2008-02-01

    Novel biomarkers of type 1 diabetes must be identified and validated in initial, exploratory studies before they can be assessed in proficiency evaluations. Currently, untargeted "-omics" approaches are underutilized in profiling studies of clinical samples. This report describes the evaluation of capillary liquid chromatography (LC) coupled with mass spectrometry (MS) in a pilot proteomic analysis of human plasma and serum from a subset of control and type 1 diabetic individuals enrolled in the Diabetes Autoantibody Standardization Program, with the goal of identifying candidate biomarkers of type 1 diabetes. Initial high-resolution capillary LC-MS/MS experiments were performed to augment an existing plasma peptide database, while subsequent LC-FTICR studies identified quantitative differences in the abundance of plasma proteins. Analysis of LC-FTICR proteomic data identified five candidate protein biomarkers of type 1 diabetes. alpha-2-Glycoprotein 1 (zinc), corticosteroid-binding globulin, and lumican were 2-fold up-regulated in type 1 diabetic samples relative to control samples, whereas clusterin and serotransferrin were 2-fold up-regulated in control samples relative to type 1 diabetic samples. Observed perturbations in the levels of all five proteins are consistent with the metabolic aberrations found in type 1 diabetes. While the discovery of these candidate protein biomarkers of type 1 diabetes is encouraging, follow up studies are required for validation in a larger population of individuals and for determination of laboratory-defined sensitivity and specificity values using blinded samples.

  13. Identifying potential markers in Breast Cancer subtypes using plasma label-free proteomics.

    PubMed

    Corrêa, Stephany; Panis, Carolina; Binato, Renata; Herrera, Ana Cristina; Pizzatti, Luciana; Abdelhay, Eliana

    2017-01-16

    Breast Cancer (BC) is the most common neoplasia among women and has a high mortality rate worldwide. Over the past several decades, increasing molecular knowledge of BC has resulted in its stratification into 4 major molecular subtypes according to hormonal receptor expression. Unfortunately, although the data accumulated thus far has improved BC prognosis and treatment, there have been few achievements in its diagnosis. In this study, we applied a Label-free Nano-LC/MSMS approach to reveal systemic molecular features and possible plasma markers for BC patients. Compared to healthy control plasma donors, we identified 191, 166, 182, and 186 differentially expressed proteins in the Luminal, Lumina-HER2, HER2, and TN subtypes. In silico analysis demonstrated an overall downregulation of cellular basal machinery and, more importantly, brought new focus to the known pathways and signaling molecules in BC that are related to immune system alterations. Moreover, using western blot analysis, we verified high levels of BCAS3, IRX1, IRX4 and IRX5 in BC plasma samples, thus highlighting the potential use of plasma proteomics in investigations into cancer biomarkers. The results of this study provide new insight into Breast Cancer (BC). We determined the plasma proteomic profile of BC subtypes. Furthermore, we report that the signaling pathways correlating with late processes in BC already exhibit plasma alterations in less aggressive subtypes. Additionally, we validated the high levels of particular proteins in patient samples, which suggests the use of these proteins as potential disease markers.

  14. Prostate cancer molecular detection in plasma samples by glutathione S-transferase P1 (GSTP1) methylation analysis.

    PubMed

    Dumache, Raluca; Puiu, Maria; Motoc, Marilena; Vernic, Corina; Dumitrascu, Victor

    2014-01-01

    Prostate cancer (PCa) represents the most commonly diagnosed type of malignancy among men in Western European countries and the second cause of cancer-related deaths among men worldwide. Methylation of the CpG island has an important role in prostate carcinogenesis and progression. The purpose of the study was to analyse the diagnostic value of aberrant promoter hypermethylation of the gene for glutathione S-transferase P1 (GSTP1) in plasma DNA to discriminate between prostate cancer (PCa) and benign prostatic hyperplasia (BPH) patients by minimally invasive methods. Aberrant promoter hypermethylation was investigated in DNA isolated from plasma samples of 31 patients with diagnostic of PCa and 44 cancer-free males (control subjects). Extracted genomic DNA was bisulfite treated and analyzed using methylation-specific polymerase chain reaction (MS-PCR) technique. Hypermethylation of the GSTP1 gene was detected in plasma samples from 27 of 31 (92.86%) patients with PCa. Genomic DNA from plasma samples from the 44 controls without genitourinary cancer revealed promoter hypermethylation of GSTP1 gene in 3 (10.6%) of the 44 patients. Receiver operating curve (ROC) included clinico-pathological parameters such as: serum PSA levels, pathological stage, Gleason score, hypermethylation status of GSTP1 gene, and it gave a predictive accuracy of 93% with a sensitivity and specificity of 95% and 87%, respectively. In this study, we have evaluated the ability of GSTP1 gene to discriminate between PCa and BPH patients in genomic DNA from plasma samples by non-invasive methods.

  15. Semi-automated 96-well solid-phase extraction and gas chromatography-negative chemical ionization tandem mass spectrometry for the trace analysis of fluprostenol in rat plasma.

    PubMed

    Gauw, R D; Stoffolano, P J; Kuhlenbeck, D L; Patel, V S; Garver, S M; Baker, T R; Wehmeyer, K R

    2000-07-21

    Semi-automated 96-well plate solid-phase extraction (SPE) was used for sample preparation of fluprostenol, a prostaglandin analog, in rat plasma prior to detection by gas chromatography-negative chemical ionization tandem mass spectrometry (GC-NCI-MS-MS). A liquid handling system was utilized for all aspects of sample handling prior to SPE including transferring of samples into a 96-well format, preparation of standards as well as addition of internal standard to standards, quality control samples and study samples. SPE was performed in a 96-well plate format using octadecylsilane packing and the effluent from the SPE was dried in a custom-made 96-well apparatus. The sample residue was derivatized sequentially with pentafluorobenzylbromide followed by N-methyl-N-trimethylsilyltrifluoroacetamide. The derivatized sample was then analyzed using GC-NCI-MS-MS. The dynamic range for the method was from 7 to 5800 pg/ml with a 0.1-ml plasma sample. The methodology was evaluated over a 4-day period and demonstrated an accuracy of 90-106% with a precision of 2.4-12.9%.

  16. Plasma choline and betaine and their relation to plasma homocysteine in normal pregnancy.

    PubMed

    Velzing-Aarts, Francien V; Holm, Pål I; Fokkema, M Rebecca; van der Dijs, Fey P; Ueland, Per M; Muskiet, Frits A

    2005-06-01

    Plasma concentrations of total homocysteine (tHcy) decrease during pregnancy. This reduction has been investigated in relation to folate status, but no study has addressed the possible role of betaine and its precursor choline. We investigated the courses of plasma choline and betaine during normal human pregnancy and their relations to plasma tHcy. Blood samples were obtained monthly; the initial samples were taken at gestational week (GW) 9, and the last samples were taken approximately 3 mo postpartum. The study population comprised 50 women of West African descent. Most of the subjects took folic acid irregularly. Plasma choline (geometric x; 95% reference interval) increased continuously during pregnancy, from 6.6 (4.5, 9.7) micromol/L at GW 9 to 10.8 (7.4, 15.6) micromol/L at GW 36. Plasma betaine decreased in the first half of pregnancy, from 16.3 (8.6, 30.8) micromol/L at GW 9 to 10.3 (6.6, 16.2) micromol/L at GW 20 and remained constant thereafter. We confirmed a reduction in plasma tHcy, and the lowest concentration was found in the second trimester. From GW 16 onward, an inverse relation between plasma tHcy and betaine was observed. Multiple regression analysis showed that plasma betaine was a strong predictor of plasma tHcy from GW 20 onward. The steady increase in choline throughout gestation may ensure choline availability for placental transfer with subsequent use by the growing fetus. Betaine becomes a strong predictor of tHcy during the course of pregnancy. Both of these findings emphasize the importance of choline and betaine status during normal human pregnancy.

  17. Validation and use of three complementary analytical methods (LC-FLS, LC-MS/MS and ICP-MS) to evaluate the pharmacokinetics, biodistribution and stability of motexafin gadolinium in plasma and tissues.

    PubMed

    Miles, Dale R; Mesfin, Mimi; Mody, Tarak D; Stiles, Mark; Lee, Jean; Fiene, John; Denis, Bernie; Boswell, Garry W

    2006-05-01

    Liquid chromatography-fluorescence (LC-FLS), liquid chromatography-tandem mass spectrometry (LC-MS/MS) and inductively coupled plasma-mass spectrometry (ICP-MS) methods were developed and validated for the evaluation of motexafin gadolinium (MGd, Xcytrin) pharmacokinetics and biodistribution in plasma and tissues. The LC-FLS method exhibited the greatest sensitivity (0.0057 microg mL(-1)), and was used for pharmacokinetic, biodistribution, and protein binding studies with small sample sizes or low MGd concentrations. The LC-MS/MS method, which exhibited a short run time and excellent selectivity, was used for routine clinical plasma sample analysis. The ICP-MS method, which measured total Gd, was used in conjunction with LC methods to assess MGd stability in plasma. All three methods were validated using human plasma. The LC-FLS method was also validated using plasma, liver and kidneys from mice and rats. All three methods were shown to be accurate, precise and robust for each matrix validated. For three mice, the mean (standard deviation) concentration of MGd in plasma/tissues taken 5 hr after dosing with 23 mg kg(-1) MGd was determined by LC-FLS as follows: plasma (0.025+/-0.002 microg mL(-1)), liver (2.89+/-0.45 microg g(-1)), and kidney (6.09+/-1.05 microg g(-1)). Plasma samples from a subset of patients with brain metastases from extracranial tumors were analyzed using both LC-MS/MS and ICP-MS methods. For a representative patient, > or = 90% of the total Gd in plasma was accounted for as MGd over the first hour post dosing. By 24 hr post dosing, 63% of total Gd was accounted for as MGd, indicating some metabolism of MGd.

  18. Inertization of heavy metals present in galvanic sludge by DC thermal plasma.

    PubMed

    Leal Vieira Cubas, Anelise; de Medeiros Machado, Marília; de Medeiros Machado, Marina; Gross, Frederico; Magnago, Rachel Faverzani; Moecke, Elisa Helena Siegel; Gonçalvez de Souza, Ivan

    2014-01-01

    Galvanic sludge results from the treatment of effluents generated by the industrial metal surface treatment of industrial material, which consists in the deposition of a metal on a surface or a metal surface attack, for example, electrodeposition of conductors (metals) and non conductive, phosphate, anodizing, oxidation and/or printed circuit. The treatment proposed here is exposure of the galvanic sludge to the high temperatures provided by thermal plasma, a process which aims to vitrify the galvanic sludge and render metals (iron, zinc, and chromium) inert. Two different plasma reactors were assembled: with a DC transferred arc plasma torch and with a DC nontransferred arc plasma torch. In this way it was possible to verify which reactor was more efficient in the inertization of the metals and also to investigate whether the addition of quartzite sand to the sludge influences the vitrification of the material. Quantification of water content and density of the galvanic raw sludge were performed, as well as analyzes of total organic carbon (TOC) and identify the elements that make up the raw sludge through spectroscopy X-ray fluorescence (XRF). The chemical composition and the form of the pyrolyzed and vitrified sludge were analyzed by scanning electron microscopy with energy-dispersive X-ray spectrometer (SEM-EDS) analysis, which it is a analysis that shows the chemical of the sample surface. The inertization of the sludge was verified in leaching tests, where the leachate was analyzed by flame atomic absorption spectroscopy (FAAS). The results of water content and density were 64.35% and 2.994 g.cm(-3), respectively. The TOC analysis determined 1.73% of C in the sample of galvanic raw sludge, and XRF analysis determined the most stable elements in the sample, and showed the highest peaks (higher stability) were Fe, Zn, and Cr. The efficiency of the sludge inertization was 100% for chromium, 99% for zinc, and 100% for iron. The results also showed that the most efficient reactor was that with the DC transferred arc plasma torch and quartzite sand positively influenced by the vitrification during the pyrolysis of the galvanic sludge.

  19. A Simple Plasma Retinol Isotope Ratio Method for Estimating β-Carotene Relative Bioefficacy in Humans: Validation with the Use of Model-Based Compartmental Analysis.

    PubMed

    Ford, Jennifer Lynn; Green, Joanne Balmer; Lietz, Georg; Oxley, Anthony; Green, Michael H

    2017-09-01

    Background: Provitamin A carotenoids are an important source of dietary vitamin A for many populations. Thus, accurate and simple methods for estimating carotenoid bioefficacy are needed to evaluate the vitamin A value of test solutions and plant sources. β-Carotene bioefficacy is often estimated from the ratio of the areas under plasma isotope response curves after subjects ingest labeled β-carotene and a labeled retinyl acetate reference dose [isotope reference method (IRM)], but to our knowledge, the method has not yet been evaluated for accuracy. Objectives: Our objectives were to develop and test a physiologically based compartmental model that includes both absorptive and postabsorptive β-carotene bioconversion and to use the model to evaluate the accuracy of the IRM and a simple plasma retinol isotope ratio [(RIR), labeled β-carotene-derived retinol/labeled reference-dose-derived retinol in one plasma sample] for estimating relative bioefficacy. Methods: We used model-based compartmental analysis (Simulation, Analysis and Modeling software) to develop and apply a model that provided known values for β-carotene bioefficacy. Theoretical data for 10 subjects were generated by the model and used to determine bioefficacy by RIR and IRM; predictions were compared with known values. We also applied RIR and IRM to previously published data. Results: Plasma RIR accurately predicted β-carotene relative bioefficacy at 14 d or later. IRM also accurately predicted bioefficacy by 14 d, except that, when there was substantial postabsorptive bioconversion, IRM underestimated bioefficacy. Based on our model, 1-d predictions of relative bioefficacy include absorptive plus a portion of early postabsorptive conversion. Conclusion: The plasma RIR is a simple tracer method that accurately predicts β-carotene relative bioefficacy based on analysis of one blood sample obtained at ≥14 d after co-ingestion of labeled β-carotene and retinyl acetate. The method also provides information about the contributions of absorptive and postabsorptive conversion to total bioefficacy if an additional sample is taken at 1 d. © 2017 American Society for Nutrition.

  20. Carbonylated plasma proteins as potential biomarkers of obesity induced type 2 diabetes mellitus.

    PubMed

    Bollineni, Ravi Chand; Fedorova, Maria; Blüher, Matthias; Hoffmann, Ralf

    2014-11-07

    Protein carbonylation is a common nonenzymatic oxidative post-translational modification, which is often considered as biomarker of oxidative stress. Recent evidence links protein carbonylation also to obesity and type 2 diabetes mellitus (T2DM), though the protein targets of carbonylation in human plasma have not been identified. In this study, we profiled carbonylated proteins in plasma samples obtained from lean individuals and obese patients with or without T2DM. The plasma samples were digested with trypsin, carbonyl groups were derivatized with O-(biotinylcarbazoylmethyl)hydroxylamine, enriched by avidin affinity chromatography, and analyzed by RPC-MS/MS. Signals of potentially modified peptides were targeted in a second LC-MS/MS analysis to retrieve the peptide sequence and the modified residues. A total of 158 unique carbonylated proteins were identified, of which 52 were detected in plasma samples of all three groups. Interestingly, 36 carbonylated proteins were detected only in obese patients with T2DM, whereas 18 were detected in both nondiabetic groups. The carbonylated proteins originated mostly from liver, plasma, platelet, and endothelium. Functionally, they were mainly involved in cell adhesion, signaling, angiogenesis, and cytoskeletal remodeling. Among the identified carbonylated proteins were several candidates, such as VEGFR-2, MMP-1, argin, MKK4, and compliment C5, already connected before to diabetes, obesity and metabolic diseases.

  1. Plasma ctDNA RAS mutation analysis for the diagnosis and treatment monitoring of metastatic colorectal cancer patients

    PubMed Central

    Vidal, J; Muinelo, L; Dalmases, A; Jones, F; Edelstein, D; Iglesias, M; Orrillo, M; Abalo, A; Rodríguez, C; Brozos, E; Vidal, Y; Candamio, S; Vázquez, F; Ruiz, J; Guix, M; Visa, L; Sikri, V; Albanell, J; Bellosillo, B; López, R; Montagut, C

    2017-01-01

    Abstract Background RAS assessment is mandatory for therapy decision in metastatic colorectal cancer (mCRC) patients. This determination is based on tumor tissue, however, genotyping of circulating tumor (ct)DNA offers clear advantages as a minimally invasive method that represents tumor heterogeneity. Our study aims to evaluate the use of ctDNA as an alternative for determining baseline RAS status and subsequent monitoring of RAS mutations during therapy as a component of routine clinical practice. Patients and methods RAS mutational status in plasma was evaluated in mCRC patients by OncoBEAM™ RAS CRC assay. Concordance of results in plasma and tissue was retrospectively evaluated. RAS mutations were also prospectively monitored in longitudinal plasma samples from selected patients. Results Analysis of RAS in tissue and plasma samples from 115 mCRC patients showed a 93% overall agreement. Plasma/tissue RAS discrepancies were mainly explained by spatial and temporal tumor heterogeneity. Analysis of clinico-pathological features showed that the site of metastasis (i.e. peritoneal, lung), the histology of the tumor (i.e. mucinous) and administration of treatment previous to blood collection negatively impacted the detection of RAS in ctDNA. In patients with baseline mutant RAS tumors treated with chemotherapy/antiangiogenic, longitudinal analysis of RAS ctDNA mirrored response to treatment, being an early predictor of response. In patients RAS wt, longitudinal monitoring of RAS ctDNA revealed that OncoBEAM was useful to detect emergence of RAS mutations during anti-EGFR treatment. Conclusion The high overall agreement in RAS mutational assessment between plasma and tissue supports blood-based testing with OncoBEAM™ as a viable alternative for genotyping RAS of mCRC patients in routine clinical practice. Our study describes practical clinico-pathological specifications to optimize RAS ctDNA determination. Moreover, OncoBEAM™ is useful to monitor RAS in patients undergoing systemic therapy to detect resistance and evaluate the efficacy of particular treatments. PMID:28419195

  2. Analysis of malondialdehyde in human plasma samples through derivatization with 2,4-dinitrophenylhydrazine by ultrasound-assisted dispersive liquid-liquid microextraction-GC-FID approach.

    PubMed

    Malaei, Reyhane; Ramezani, Amir M; Absalan, Ghodratollah

    2018-05-04

    A sensitive and reliable ultrasound-assisted dispersive liquid-liquid microextraction (UA-DLLME) procedure was developed and validated for extraction and analysis of malondialdehyde (MDA) as an important lipids-peroxidation biomarker in human plasma. In this methodology, to achieve an applicable extraction procedure, the whole optimization processes were performed in human plasma. To convert MDA into readily extractable species, it was derivatized to hydrazone structure-base by 2,4-dinitrophenylhydrazine (DNPH) at 40 °C within 60 min. Influences of experimental variables on the extraction process including type and volume of extraction and disperser solvents, amount of derivatization agent, temperature, pH, ionic strength, sonication and centrifugation times were evaluated. Under the optimal experimental conditions, the enhancement factor and extraction recovery were 79.8 and 95.8%, respectively. The analytical signal linearly (R 2  = 0.9988) responded over a concentration range of 5.00-4000 ng mL -1 with a limit of detection of 0.75 ng mL -1 (S/N = 3) in the plasma sample. To validate the developed procedure, the recommend guidelines of Food and Drug Administration for bioanalytical analysis have been employed. Copyright © 2018. Published by Elsevier B.V.

  3. Laser-induced breakdown spectroscopy (LIBS), part I: review of basic diagnostics and plasma-particle interactions: still-challenging issues within the analytical plasma community.

    PubMed

    Hahn, David W; Omenetto, Nicoló

    2010-12-01

    Laser-induced breakdown spectroscopy (LIBS) has become a very popular analytical method in the last decade in view of some of its unique features such as applicability to any type of sample, practically no sample preparation, remote sensing capability, and speed of analysis. The technique has a remarkably wide applicability in many fields, and the number of applications is still growing. From an analytical point of view, the quantitative aspects of LIBS may be considered its Achilles' heel, first due to the complex nature of the laser-sample interaction processes, which depend upon both the laser characteristics and the sample material properties, and second due to the plasma-particle interaction processes, which are space and time dependent. Together, these may cause undesirable matrix effects. Ways of alleviating these problems rely upon the description of the plasma excitation-ionization processes through the use of classical equilibrium relations and therefore on the assumption that the laser-induced plasma is in local thermodynamic equilibrium (LTE). Even in this case, the transient nature of the plasma and its spatial inhomogeneity need to be considered and overcome in order to justify the theoretical assumptions made. This first article focuses on the basic diagnostics aspects and presents a review of the past and recent LIBS literature pertinent to this topic. Previous research on non-laser-based plasma literature, and the resulting knowledge, is also emphasized. The aim is, on one hand, to make the readers aware of such knowledge and on the other hand to trigger the interest of the LIBS community, as well as the larger analytical plasma community, in attempting some diagnostic approaches that have not yet been fully exploited in LIBS.

  4. Atmospheric pressure plasma jet's characterization and surface wettability driven by neon transformer

    NASA Astrophysics Data System (ADS)

    Elfa, R. R.; Nafarizal, N.; Ahmad, M. K.; Sahdan, M. Z.; Soon, C. F.

    2017-03-01

    Atmospheric pressure plasma driven by Neon transformer power supply argon is presented in this paper. Atmospheric pressure plasma system has attracted researcher interest over low pressure plasma as it provides a flexibility process, cost-efficient, portable device and vacuum-free device. Besides, another golden key of this system is the wide promising application in the field of work cover from industrial and engineering to medical. However, there are still numbers of fundamental investigation that are necessary such as device configuration, gas configuration and its effect. Dielectric barrier discharge which is also known as atmospheric pressure plasma discharge is created when there is gas ionization process occur which enhance the movement of atom and electron and provide energetic particles. These energetic particles can provide modification and cleaning property to the sample surface due to the bombardment of the high reactive ion and radicals to the sample surface. In order to develop atmospheric pressure plasma discharge, a high voltage and high frequency power supply is needed. In this work, we used a neon transformer power supply as the power supply. The flow of the Ar is feed into 10 mm cylinder quartz tube with different treatment time in order to investigate the effect of the plasma discharge. The analysis of each treatment time is presented by optical emission spectroscopy (OES) and water contact angle (WCA) measurement. The increase of gas treatment time shows increases intensity of reactive Ar and reduces the angle of water droplets in water contact angle. Treatment time of 20 s microslide glass surface shows that the plasma needle discharges have modified the sample surface from hydrophilic surface to superhydrophilic surface. Thus, this leads to another interesting application in reducing sample surface adhesion to optimize productivity in the industry of paintings, semiconductor and more.

  5. Systematic Evaluation of the Use of Human Plasma and Serum for Mass-Spectrometry-Based Shotgun Proteomics.

    PubMed

    Lan, Jiayi; Núñez Galindo, Antonio; Doecke, James; Fowler, Christopher; Martins, Ralph N; Rainey-Smith, Stephanie R; Cominetti, Ornella; Dayon, Loïc

    2018-04-06

    Over the last two decades, EDTA-plasma has been used as the preferred sample matrix for human blood proteomic profiling. Serum has also been employed widely. Only a few studies have assessed the difference and relevance of the proteome profiles obtained from plasma samples, such as EDTA-plasma or lithium-heparin-plasma, and serum. A more complete evaluation of the use of EDTA-plasma, heparin-plasma, and serum would greatly expand the comprehensiveness of shotgun proteomics of blood samples. In this study, we evaluated the use of heparin-plasma with respect to EDTA-plasma and serum to profile blood proteomes using a scalable automated proteomic pipeline (ASAP 2 ). The use of plasma and serum for mass-spectrometry-based shotgun proteomics was first tested with commercial pooled samples. The proteome coverage consistency and the quantitative performance were compared. Furthermore, protein measurements in EDTA-plasma and heparin-plasma samples were comparatively studied using matched sample pairs from 20 individuals from the Australian Imaging, Biomarkers and Lifestyle (AIBL) Study. We identified 442 proteins in common between EDTA-plasma and heparin-plasma samples. Overall agreement of the relative protein quantification between the sample pairs demonstrated that shotgun proteomics using workflows such as the ASAP 2 is suitable in analyzing heparin-plasma and that such sample type may be considered in large-scale clinical research studies. Moreover, the partial proteome coverage overlaps (e.g., ∼70%) showed that measures from heparin-plasma could be complementary to those obtained from EDTA-plasma.

  6. Quantitative analysis of Al-Si alloy using calibration free laser induced breakdown spectroscopy (CF-LIBS)

    NASA Astrophysics Data System (ADS)

    Shakeel, Hira; Haq, S. U.; Aisha, Ghulam; Nadeem, Ali

    2017-06-01

    The quantitative analysis of the standard aluminum-silicon alloy has been performed using calibration free laser induced breakdown spectroscopy (CF-LIBS). The plasma was produced using the fundamental harmonic (1064 nm) of the Nd: YAG laser and the emission spectra were recorded at 3.5 μs detector gate delay. The qualitative analysis of the emission spectra confirms the presence of Mg, Al, Si, Ti, Mn, Fe, Ni, Cu, Zn, Sn, and Pb in the alloy. The background subtracted and self-absorption corrected emission spectra were used for the estimation of plasma temperature as 10 100 ± 300 K. The plasma temperature and self-absorption corrected emission lines of each element have been used for the determination of concentration of each species present in the alloy. The use of corrected emission intensities and accurate evaluation of plasma temperature yield reliable quantitative analysis up to a maximum 2.2% deviation from reference sample concentration.

  7. Non-uniform Erosion and Surface Evolution of Plasma-Facing Materials for Electric Propulsion

    NASA Astrophysics Data System (ADS)

    Matthes, Christopher Stanley Rutter

    A study regarding the surface evolution of plasma-facing materials is presented. Experimental efforts were performed in the UCLA Pi Facility, designed to explore the physics of plasma-surface interactions. The influence of micro-architectured surfaces on the effects of plasma sputtering is compared with the response of planar samples. Ballistic deposition of sputtered atoms as a result of geometric re-trapping is observed. This provides a self-healing mechanism of micro-architectured surfaces during plasma exposure. This result is quantified using a QCM to demonstrate the evolution of surface features and the corresponding influence on the instantaneous sputtering yield. The sputtering yield of textured molybdenum samples exposed to 300 eV Ar plasma is found to be roughly 1 of the 2 corresponding value of flat samples, and increases with ion fluence. Mo samples exhibited a sputtering yield initially as low as 0.22+/-8%, converging to 0.4+/-8% at high fluence. Although the yield is dependent on the initial surface structure, it is shown to be transient, reaching a steady-state value that is independent of initial surface conditions. A continuum model of surface evolution resulting from sputtering, deposition and surface diffusion is also derived to resemble the damped Kuramoto-Sivashinsky (KS) equation of non-linear dynamics. Linear stability analysis of the evolution equation provides an estimate of the selected wavelength, and its dependence on the ion energy and angle of incidence. The analytical results are confirmed by numerical simulations of the equation with a Fast Fourier Transform method. It is shown that for an initially flat surface, small perturbations lead to the evolution of a selected surface pattern that has nano- scale wavelength. When the surface is initially patterned by other means, the final resulting pattern is a competition between the "templated" pattern and the "self-organized" structure. Potential future routes of research are also discussed, corresponding to a design analysis of the current experimental study.

  8. The interplay of plasma treatment and gold coating and ultra-high molecular weight polyethylene: On the cytocompatibility.

    PubMed

    Novotná, Zdenka; Rimpelová, Silvie; Juřík, Petr; Veselý, Martin; Kolská, Zdenka; Hubáček, Tomáš; Ruml, Tomáš; Švorčík, Václav

    2017-02-01

    We have investigated the application of Ar plasma for creation of nanostructured ultra high molecular weight polyethylene (PE) surface in order to enhance adhesion of mouse embryonic fibroblasts (L929). The aim of this study was to investigate the effect of the interface between plasma-treated and gold-coated PE on adhesion and spreading of cells. The surface properties of pristine samples and its modified counterparts were studied by different experimental techniques (gravimetry, goniometry and X-ray photoelectron spectroscopy (XPS), electrokinetic analysis), which were used for characterization of treated and sputtered layers, polarity and surface chemical structure, respectively. Further, atomic force microscopy (AFM) was employed to study the surface morphology and roughness. Biological responses of cells seeded on PE samples were evaluated in terms of cell adhesion, spreading, morphology and proliferation. Detailed cell morphology and intercellular connections were followed by scanning electron microscopy (SEM). As it was expected the thickness of a deposited gold film was an increasing function of the sputtering time. Despite the fact that plasma treatment proceeded in inert plasma, oxidized degradation products were formed on the PE surface which would contribute to increased hydrophilicity (wettability) of the plasma treated polymer. The XPS method showed a decrease in carbon concentration with increasing plasma treatment. Cell adhesion measured on the interface between plasma treated and gold coated PE was inversely proportional to the thickness of a gold layer on a sample. Copyright © 2016. Published by Elsevier B.V.

  9. Atmospheric-pressure DBD plasma-assisted surface modification of polymethyl methacrylate: A study on cell growth/proliferation and antibacterial properties

    NASA Astrophysics Data System (ADS)

    Rezaei, Fatemeh; Shokri, Babak; Sharifian, M.

    2016-01-01

    This paper reports polymethyl methacrylate (PMMA) surface modification by atmospheric-pressure oxygen dielectric barrier discharge (DBD) plasma to improve its biocompatibility and antibacterial effects. The role of plasma system parameters, such as electrode gap, treatment time and applied voltage, on the surface characteristics and biological responses was studied. The surface characteristics of PMMA films before and after the plasma treatments were analyzed by water contact angle (WCA) goniometry, atomic force microscopy (AFM) and attenuated total reflection Fourier transform infrared spectroscopy (ATR-FTIR). Also, acid-base approach was used for evaluation of surface free energy (SFE) and its components. Stability of plasma treatment or aging effect was examined by repeating water contact angle measurements in a period of 9 days after treatment. Moreover, the antibacterial properties of samples were investigated by bacterial adhesion assay against Escherichia coli. Additionally, all samples were tested for the biocompatibility by cell viability assay of mouse embryonic fibroblast. WCA measurements indicated that the surface wettability of PMMA films was improved by increasing surface free energy via oxygen DBD plasma treatments. AFM measurement revealed that surface roughness was slightly increased after treatments, and ATR-FTIR analysis showed that more polar groups were introduced on the plasma-treated PMMA film surface. The results also demonstrated an enhancement of antibacterial performance of the modified surfaces. Furthermore, it was observed that plasma-treated samples exhibited significantly better biocompatibility, comparing to the pristine one.

  10. Validation of a method for the determination of zolpidem in human plasma using LC with fluorescence detection.

    PubMed

    Ring, P R; Bostick, J M

    2000-04-01

    A sensitive and selective high-performance liquid chromatography (HPLC) method was developed for the determination of zolpidem in human plasma. Zolpidem and the internal standard (trazodone) were extracted from human plasma that had been made basic. The basic sample was loaded onto a conditioned Bond Elut C18 cartridge, rinsed with water and eluted with methanol. Forty microliters were then injected onto the LC system. Separation was achieved on a C18 column (150 x 4.6 mm, 5 microm) with a mobile phase composed of acetonitrile:50 mM potassium phosphate monobasic at pH 6.0 (4:6, v/v). Detection was by fluorescence, with excitation at 254 nm and emission at 400 nm. The retention times of zolpidem and internal standard were approximately 4.7 and 5.3 min, respectively. The LC run time was 8 min. The assay was linear in concentration range 1-400 ng/ml for zolpidem in human plasma. The analysis of quality control samples for zolpidem (3, 30, and 300 ng/ml) demonstrated excellent precision with relative standard deviations (RSD) of 3.7, 4.6, and 3.0%, respectively (n = 18). The method was accurate with all intraday (n = 6) and overall (n = 18) mean concentrations within 5.8% from nominal at all quality control sample concentrations. This method was also performed using a Gilson Aspec XL automated sample processor and autoinjector. The samples were manually fortified with internal standard and made basic. The aspec then performed the solid phase extraction and made injections of the samples onto the LC system. Using the automated procedure for analysis, quality control samples for zolpidem (3, 30, and 300 ng/ml) demonstrated acceptable precision with RSD values of 9.0, 4.9, and 5.1%, respectively (n = 12). The method was accurate with all intracurve (n = 4) and overall (n = 12) mean values being less than 10.8% from nominal at all quality control sample concentrations.

  11. Multiple stage MS in analysis of plasma, serum, urine and in vitro samples relevant to clinical and forensic toxicology.

    PubMed

    Meyer, Golo M; Maurer, Hans H; Meyer, Markus R

    2016-01-01

    This paper reviews MS approaches applied to metabolism studies, structure elucidation and qualitative or quantitative screening of drugs (of abuse) and/or their metabolites. Applications in clinical and forensic toxicology were included using blood plasma or serum, urine, in vitro samples, liquids, solids or plant material. Techniques covered are liquid chromatography coupled to low-resolution and high-resolution multiple stage mass analyzers. Only PubMed listed studies published in English between January 2008 and January 2015 were considered. Approaches are discussed focusing on sample preparation and mass spectral settings. Comments on advantages and limitations of these techniques complete the review.

  12. Electrochemical approach for acute myocardial infarction diagnosis based on direct antibodies-free analysis of human blood plasma.

    PubMed

    Suprun, Elena V; Saveliev, Anatoly A; Evtugyn, Gennady A; Lisitsa, Alexander V; Bulko, Tatiana V; Shumyantseva, Victoria V; Archakov, Alexander I

    2012-03-15

    A novel direct antibodies-free electrochemical approach for acute myocardial infarction (AMI) diagnosis has been developed. For this purpose, a combination of the electrochemical assay of plasma samples with chemometrics was proposed. Screen printed carbon electrodes modified with didodecyldimethylammonium bromide were used for plasma charactrerization by cyclic (CV) and square wave voltammetry and square wave (SWV) voltammetry. It was shown that the cathodic peak in voltammograms at about -250 mV vs. Ag/AgCl can be associated with AMI. In parallel tests, cardiac myoglobin and troponin I, the AMI biomarkers, were determined in each sample by RAMP immunoassay. The applicability of the electrochemical testing for AMI diagnostics was confirmed by statistical methods: generalized linear model (GLM), linear discriminant analysis (LDA) and quadratic discriminant analysis (QDA), artificial neural net (multi-layer perception, MLP), and support vector machine (SVM), all of which were created to obtain the "True-False" distribution prediction where "True" and "False" are, respectively, positive and negative decision about an illness event. Copyright © 2011 Elsevier B.V. All rights reserved.

  13. Comparison of Analytical Methods for the Determination of Uranium in Seawater Using Inductively Coupled Plasma Mass Spectrometry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wood, Jordana R.; Gill, Gary A.; Kuo, Li-Jung

    2016-04-20

    Trace element determinations in seawater by inductively coupled plasma mass spectrometry are analytically challenging due to the typically very low concentrations of the trace elements and the potential interference of the salt matrix. In this study, we did a comparison for uranium analysis using inductively coupled plasma mass spectrometry (ICP-MS) of Sequim Bay seawater samples and three seawater certified reference materials (SLEW-3, CASS-5 and NASS-6) using seven different analytical approaches. The methods evaluated include: direct analysis, Fe/Pd reductive precipitation, standard addition calibration, online automated dilution using an external calibration with and without matrix matching, and online automated pre-concentration. The methodmore » which produced the most accurate results was the method of standard addition calibration, recovering uranium from a Sequim Bay seawater sample at 101 ± 1.2%. The on-line preconcentration method and the automated dilution with matrix-matched calibration method also performed well. The two least effective methods were the direct analysis and the Fe/Pd reductive precipitation using sodium borohydride« less

  14. Persistence of uranium emission in laser-produced plasmas

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    LaHaye, N. L.; Harilal, S. S., E-mail: hari@purdue.edu; Diwakar, P. K.

    2014-04-28

    Detection of uranium and other nuclear materials is of the utmost importance for nuclear safeguards and security. Optical emission spectroscopy of laser-ablated U plasmas has been presented as a stand-off, portable analytical method that can yield accurate qualitative and quantitative elemental analysis of a variety of samples. In this study, optimal laser ablation and ambient conditions are explored, as well as the spatio-temporal evolution of the plasma for spectral analysis of excited U species in a glass matrix. Various Ar pressures were explored to investigate the role that plasma collisional effects and confinement have on spectral line emission enhancement andmore » persistence. The plasma-ambient gas interaction was also investigated using spatially resolved spectra and optical time-of-flight measurements. The results indicate that ambient conditions play a very important role in spectral emission intensity as well as the persistence of excited neutral U emission lines, influencing the appropriate spectral acquisition conditions.« less

  15. Plasma mixing glow discharge device for analytical applications

    DOEpatents

    Pinnaduwage, Lal A.

    1999-01-01

    An instrument for analyzing a sample has an enclosure that forms a chamber containing an anode which divides the chamber into a discharge region and an analysis region. A gas inlet and outlet are provided to introduce and exhaust a rare gas into the discharge region. A cathode within the discharge region has a plurality of pins projecting in a geometric pattern toward the anode for exciting the gas and producing a plasma discharge between the cathode and the anode. Low energy electrons (e.g. <0.5 eV) pass into the analysis region through an aperture. The sample to be analyzed is placed into the analysis region and bombarded by the metastable rare gas atoms and the low energy electrons extracted into from the discharge region. A mass or optical spectrometer can be coupled to a port of the analysis region to analyze the resulting ions and light emission.

  16. Plasma mixing glow discharge device for analytical applications

    DOEpatents

    Pinnaduwage, L.A.

    1999-04-20

    An instrument for analyzing a sample has an enclosure that forms a chamber containing an anode which divides the chamber into a discharge region and an analysis region. A gas inlet and outlet are provided to introduce and exhaust a rare gas into the discharge region. A cathode within the discharge region has a plurality of pins projecting in a geometric pattern toward the anode for exciting the gas and producing a plasma discharge between the cathode and the anode. Low energy electrons (e.g. <0.5 eV) pass into the analysis region through an aperture. The sample to be analyzed is placed into the analysis region and bombarded by the metastable rare gas atoms and the low energy electrons extracted into from the discharge region. A mass or optical spectrometer can be coupled to a port of the analysis region to analyze the resulting ions and light emission. 3 figs.

  17. Contributions to process monitoring by laser-induced breakdown spectroscopy

    NASA Astrophysics Data System (ADS)

    Rusak, David Alexander

    1998-12-01

    When a pulsed laser of sufficient energy and pulse duration is brought to a focus, multi-photon ionization creates free electrons in the focal volume. These electrons are accelerated in a process known as inverse Bremsstrahlung and cause collisional ionization of species in the focal volume. More charge carriers are produced and the process continues for the duration of the laser pulse. The manifestation of this process is a visible spark or plasma which typically lasts for tens of microseconds. This laser-induced plasma can serve as a source in an atomic emission experiment. Because the composition of the plasma is determined in large part by the environment in which it forms, elements in the laser target can be determined spectroscopically. The goal of a laser-induced breakdown spectroscopy (LIBS) experiment is to establish a relationship between the concentration of an element of interest in the target and the intensity of light emitted from the laser-induced plasma at a wavelength characteristic of that element. Because LIBS requires only optical access to the sample and can perform elemental determinations in solids, liquids, or gases with little sample preparation, there is interest in using it as an on-line technique for process monitoring in a number of industrial applications. However, before the technique becomes useful in industrial applications, many issues regarding instrumentation and data analysis need to be addressed in the lab. The first two chapters of this dissertation provide, respectively, the basics of the atomic emission experiment and a background of laser-induced breakdown spectroscopy. The next two chapters examine the effect of target water content on the laser-induced plasma and the use of LIBS for analysis of aqueous samples. Chapter 5 describes construction of a fiber optic LIBS probe and its use to study temporal electron number density evolution in plasmas formed on different metals. Chapter 6 is a study of excitation, vibrational, and rotational temperatures in plasmas formed by ultraviolet and infrared laser beams. The last chapter is a brief assessment of classification software for analysis of LIBS data and a discussion of future work.

  18. THE DEVELOPMENT OF IODINE BASED IMPINGER SOLUTIONS FOR THE EFFICIENT CAPTURE OF HG USING DIRECT INJECTION NEBULIZATION - INDUCTIVELY COUPLED PLASMA MASS SPECTROMETRY ANALYSIS

    EPA Science Inventory

    Inductively coupled plasma mass spectrometry (ICP/MS) with direct injection nebulization (DIN) was used to evaluate novel impinger solution compositions capable of capturing elemental mercury (Hgo) in EPA Method 5 type sampling. An iodine based impinger solutoin proved to be ver...

  19. Analysis of glow discharges for understanding the process of film formation

    NASA Technical Reports Server (NTRS)

    Venugopalan, M.; Avni, R.

    1984-01-01

    The physical and chemical processes which occur during the formation of different types of films in a variety of glow discharge plasmas are discussed. Emphasis is placed on plasma diagnostic experiments using spectroscopic methods, probe analysis, mass spectrometric sampling and magnetic resonance techniques which are well suited to investigate the neutral and ionized gas phase species as well as some aspects of plasma surface interactions. The results on metallic, semi-conducting and insulating films are reviewed in conjunction with proposed models and the problem encountered under film deposition conditions. It is concluded that the understanding of film deposition process requires additional experimental information on plasma surface interactions of free radicals and the synergetic effects where photon, electron and ion bombardment change the reactivity of the incident radical with the surface.

  20. Examining the temperature behavior of stainless steel surfaces exposed to hydrogen plasmas in the Lithium Tokamak eXperiment (LTX)

    NASA Astrophysics Data System (ADS)

    Bedoya, Felipe; Allain, Jean Paul; Kaita, Robert; Lucia, Matthew; St-Onge, Denis; Ellis, Robert; Majeski, Richard

    2014-10-01

    The Materials Analysis Particle Probe (MAPP) is an in-situ diagnostic designed to characterize plasma-facing components (PFCs) in tokamak devices. MAPP is installed in LTX at Princeton Plasma Physics Laboratory. MAPP's capabilities include remotely operated XPS acquisition and temperature control of four samples. The recent addition of a focused ion beam allows XPS depth profiling analysis. Recent published results show an apparent correlation between hydrogen retention and temperature of Li coated stainless steel (SS) PFCs exposed to plasmas like those of LTX. According to XPS data, the retention of hydrogen by the coated surfaces decreases at above 180 °C. In the present study MAPP will be used to study the oxidation of Li coatings as a function of time and temperature of the walls when Li coatings are applied. Experiments in the ion-surface interaction experiment (IIAX) varying the hydrogen fluence on the SS samples will be also performed. Conclusions resulting from this study will be key to explain the PFC temperature-dependent variation of plasma performance observed in LTX. This work was supported by U.S. DOE Contracts DE-AC02-09CH11466, DE-AC52-07NA27344 and DE-SC0010717.

  1. Fundamental and Applied Investigations in Atomic Spectrometric Analysis

    NASA Astrophysics Data System (ADS)

    Wu, Min

    Simultaneous laser-excited fluorescence and absorption measurements were performed and the results have revealed that any interference caused by easily ionized elements does not originate from variations in analyte emission (quantum) efficiency. A closely related area, the roles of wet and dry aerosols in the matrix interference are clarified through spatially resolved imaging of the plasma by a charged coupled device camera. To eliminate matrix interference effects practically, various methods have been developed based on the above studies. The use of column pre-concentration with flow injection analysis has been found to provide a simple solution for reducing interference effects and increasing sensitivity of elemental analysis. A novel mini-spray chamber was invented. The new vertical rotary spray chamber combines gravitational, centrifugal, turbulent, and impact droplet segregation mechanisms to achieve a higher efficiency of small-droplet formation in a nebulized sample spray. As a result, it offers also higher sample-transport efficiency, lower memory effects, and improved analytical figures of merit over existing devices. This new device was employed with flow injection analysis to simulate an interface for coupling high performance liquid chromatography (HPLC) to a microwave plasma for chromatographic detection. The detection limits for common metallic elements are in the range of 5-50 mug/mL, and are degraded only twofold when the elements are presented in an organic solvent such as ethanol or methanol. Other sample-introduction schemes have also been investigated to improve sample-introduction technology. The direct coupling of hydride-generation techniques to the helium microwave plasma torch was evaluated for the determination of arsenic, antimony and tin by atomic emission spectrometry. A manually controlled peristaltic pump was modified for computer control and continuous flow injection was evaluated for standard calibration and trace elemental analysis. The present work evaluates the coupling of a novel microwave plasma torch with a quadruple mass spectrometer for the detection of ionic species from different nonmetals. Initial work performed with such a combination is demonstrated to be not only practicable but also promising. Detection limits for the halogens (F, Cl, Br, I) and S are in the range between 10 ng/mL and 1mug/mL. Further improvements have been realized through the use of chemical -vapor generation and by optimization of the plasma and the mass spectrometer. (Abstract shortened by UMI.).

  2. Simultaneous determination of nicotine, cotinine, and nicotine N-oxide in human plasma, semen, and sperm by LC-Orbitrap MS.

    PubMed

    Abu-Awwad, Ahmad; Arafat, Tawfiq; Schmitz, Oliver J

    2016-09-01

    Nicotine (Nic) distribution in human fluids and tissues has a deleterious effect on human health. In addition to its poisoning profile, Nic may contribute to the particular impact of smoking on human reproduction. Although present in seminal fluid, still nobody knows whether nicotine is available in sperm or not. Herein, we developed and validated a new bioanalytical method, for simultaneous determination of Nic, cotinine (Cot), and nicotine N'-oxide (Nox) in human plasma, semen, and sperm by LC-ESI-orbitrap-MS. Blood and semen samples were collected from 12 healthy smoking volunteers in this study. Sperm bodies were then separated quantitatively from 1 mL of semen samples by centrifugation. The developed method was fully validated for plasma following European and American guidelines for bioanalytical method validation, and partial validation was applied to semen analysis. Plasma, semen, and sperm samples were treated by trichloroacetic acid solution for protein direct precipitation in single extraction step. The established calibration range for Nic and Nox in plasma and semen was linear between 5 and 250 ng/mL, and for Cot between 10 and 500 ng/mL. Nic and Cot were detected in human sperm at concentrations as high as in plasma. In addition, Nox was present in semen and sperm but not in plasma. Graphical abstract Nicotine correlation between plasma and semen a; Nicotine correlation between semen and sperm c; Cotinine correlation between plasma and semen b; Cotinine correlation between semen and sperm d.

  3. Evaluation of on-line desalter-inductively coupled plasma-mass spectrometry system for determination of Cr(III), Cr(VI), and total chromium concentrations in natural water and urine samples

    NASA Astrophysics Data System (ADS)

    Sun, Y. C.; Lin, C. Y.; Wu, S. F.; Chung, Y. T.

    2006-02-01

    We have developed a simple and convenient method for the determination of Cr(III), Cr(VI), and the total chromium concentrations in natural water and urine samples that use a flow injection on-line desalter-inductively coupled plasma-mass spectrometry system. When using aqueous ammonium chloride (pH 8) as the stripping solution, the severe interference from sodium in the matrix can be eliminated prior to inductively coupled plasma-mass spectrometry measurement, and the Cr(VI) level can be determined directly. To determine the total concentration of Cr in natural water and urine samples, we used H 2O 2 or HNO 3 to decompose the organic matter and convert all chromium species into the Cr(VI) oxidation state. To overcome the spectral interference caused by the matrix chloride ion in the resulting solutions, we employed cool plasma to successfully suppress chloride-based molecular ion interference during the inductively coupled plasma-mass spectrometry measurement. By significantly eliminating interference from the cationic and anionic components in the matrices prior to the inductively coupled plasma-mass spectrometry measurement, we found that the detection limit reached 0.18 μg L - 1 (based on 3 sigma). We validated this method through the analysis of the total chromium content in two reference materials (NIST 1643c and 2670E) and through measuring the recovery in spiked samples.

  4. Plasma clot formation and clot lysis to compare effects of different anticoagulation treatments on hemostasis in patients with atrial fibrillation.

    PubMed

    Königsbrügge, Oliver; Weigel, Günter; Quehenberger, Peter; Pabinger, Ingrid; Ay, Cihan

    2018-02-07

    The effect of direct oral anticoagulants (DOACs) on turbidimetric measurements of plasma clot formation and susceptibility to fibrinolysis may facilitate a comparison between different classes of anticoagulants in plasma samples. We obtained 424 citrate plasma samples from 226 atrial fibrillation patients on anticoagulation and 24 samples without anticoagulation serving as controls. As comparators, we measured the international normalized ratio (INR) for phenprocoumon samples (N = 166), anti-Xa for low molecular weight heparin (LMWH) samples (N = 42), and DOAC levels with mass spectrometry (dabigatran N = 40, rivaroxaban N = 110, apixaban N = 42). Plasma clot formation and lysis were recorded continuously on a photometer after addition of an activation mix (tissue factor 2 pmol/l and tissue plasminogen activator 333 ng/ml). We used linear regression and ANCOVA for correlation analysis. Clot formation lag phase was prolonged in the presence of anticoagulants in a concentration-dependent manner for DOACs (dabigatran Spearman r = 0.74; rivaroxaban r = 0.78; apixaban r = 0.72, all p < 0.0001), INR dependent for phenprocoumon (r = 0.59, p < 0.0001), anti-Xa level dependent in LMWH samples (r = 0.90, p < 0.0001). Maximum rate of clot formation and peak clot turbidity were reduced in the presence of anticoagulants, but correlated only moderately with the comparator measures of anticoagulation. The clot lysis time was inversely correlated with DOAC concentrations in the presence of recombinant thrombomodulin. A direct ex vivo comparison between the effects of different classes of anticoagulants is possible with turbidimetric measurement of plasma clot formation and lysis. Anticoagulation inhibited clot formation in a plasma concentration manner for DOACs, INR dependent for phenprocoumon, and anti-Xa dependent for LMWH. Susceptibility to fibrinolysis increased with increasing DOAC concentrations.

  5. Multielement analysis of Zanthoxylum bungeanum Maxim. essential oil using ICP-MS/MS.

    PubMed

    Fu, Liang; Xie, Hualin; Shi, Shuyun

    2018-06-01

    The concentrations of trace elements (Cr, Ni, As, Cd, Hg, and Pb) in Zanthoxylum bungeanum Maxim. essential oil (ZBMEO) were determined by inductively coupled plasma tandem mass spectrometry. The ZBMEO sample was directly analyzed after simple dilution with n-hexane. Aiming for a relatively high vapor pressure of n-hexane and its resultant loading on plasma, we used a narrow injector torch and optimized plasma radio frequency power and carrier gas flow to ensure stable operation of the plasma. An optional gas flow of 20% O 2 in Ar was added to the carrier gas to prevent the incomplete combustion of highly concentrated organic carbon in plasma and the deposition of carbon on the sampling and skimmer cone orifices. In tandem mass spectrometry mode, O 2 was added to the collision/reaction cell to eliminate the interferences. The limits of detection for Cr, Ni, As, Cd, Hg, and Pb were 2.26, 1.64, 2.02, 1.35, 1.76, and 0.97 ng L -1 , respectively. After determination of 23 ZBMEO samples from different regions in China, we found that the average concentration ranges of trace elements in the 23 ZBMEO samples were 0.72-6.02 ng g -1 , 0.09-2.87 ng g -1 , 0.21-5.84 ng g -1 , 0.16-2.15 ng g -1 , 0.13-0.92 ng g -1 , and 0.17-0.73 ng g -1 for Cr, Ni, As, Cd, Hg, and Pb, respectively. The trace elements in ZBMEO differed significantly when different extraction technologies were used. The study revealed that the contents of the toxic elements As, Cd, Hg, and Pb were extremely low, and hence they are unlikely to pose a health risk following ZBMEO ingestion. Graphical abstract The working mechanism of sample analysis by ICP-MS/MS.

  6. Relationship between substances in seminal plasma and Acrobeads Test results.

    PubMed

    Komori, Kazuhiko; Tsujimura, Akira; Okamoto, Yoshio; Matsuoka, Yasuhiro; Takao, Tetsuya; Miyagawa, Yasushi; Takada, Shingo; Nonomura, Norio; Okuyama, Akihiko

    2009-01-01

    To asses the effects of seminal plasma on sperm function. Retrospective case-control study. University hospital. One hundred fourteen infertile men. Acrobeads Test scores (0-4) and measurement of interleukin (IL)-6, soluble IL-6 receptor, epidermal growth factor, insulin-like growth factor-I (IGF-I), transforming growth factor-beta I, superoxide dismutase, calcitonin, and macrophage migration inhibitory factor (MIF) levels in seminal plasma. Kruskal-Wallis test to compare the concentrations of substances as a nonparametric test for differences among Acrobeads Test scores and a multivariable logistic regression model to find independent risk factors associated with abnormal Acrobeads Test results. The Acrobeads Test score was 0 for 7 samples, 1 for 20 samples, 2 for 18 samples, 3 for 28 samples, and 4 for 41 samples. Age, abstinence period, and semen parameters, except for sperm motility and percentage of sperm with abnormal morphology, had no effect on the Acrobeads Test results. Concentrations of IGF-I and MIF were significantly higher in patients with abnormal Acrobeads Test results. Multivariate analysis indicated that MIF and IGF-I were significantly associated with abnormal Acrobeads Test results (scores 0 to 1). Although further studies are needed, IGF-I and MIF in seminal plasma may have negative effects on sperm function.

  7. Quantitative determination of total cesium in highly active liquid waste by using liquid electrode plasma optical emission spectrometry.

    PubMed

    Do, Van-Khoai; Yamamoto, Masahiko; Taguchi, Shigeo; Takamura, Yuzuru; Surugaya, Naoki; Kuno, Takehiko

    2018-06-01

    A sensitive analytical method for determination of total cesium (Cs) in highly active liquid waste (HALW) by using modified liquid electrode plasma optical emission spectrometry (LEP-OES) is developed in this study. The instrument is modified to measure radioactive samples in a glove box. The effects of important factors, including pulsed voltage sequence and nitric acid concentration, on the emission of Cs are investigated. The limit of detection (LOD) and limit of quantification (LOQ) are 0.005 mg/L and 0.02 mg/L, respectively. The achieved LOD is one order lower than that of recently developed spectroscopic methods using liquid discharge plasma. The developed method is validated by subjecting a simulated HALW sample to inductively coupled plasma mass spectrometry (ICP-MS). The recoveries obtained from a spike-and-recovery test are 96-102%, implying good accuracy. The method is successfully applied to the quantification of Cs in a real HALW sample at the Tokai reprocessing plant in Japan. Apart from dilution and filtration of the HALW sample, no other pre-treatment process is required. The results agree well with the values obtained using gamma spectrometry. The developed method offers a reliable technique for rapid analysis of total Cs in HALW samples. Copyright © 2018 Elsevier B.V. All rights reserved.

  8. Proteins and antibodies in serum, plasma, and whole blood-size characterization using asymmetrical flow field-flow fractionation (AF4).

    PubMed

    Leeman, Mats; Choi, Jaeyeong; Hansson, Sebastian; Storm, Matilda Ulmius; Nilsson, Lars

    2018-05-29

    The analysis of aggregates of therapeutic proteins is crucial in order to ensure efficacy and patient safety. Typically, the analysis is performed in the finished formulation to ensure that aggregates are not present. An important question is, however, what happens to therapeutic proteins, with regard to oligomerization and aggregation, after they have been administrated (i.e., in the blood). In this paper, the separation of whole blood, plasma, and serum is shown using asymmetric flow field-flow fractionation (AF4) with a minimum of sample pre-treatment. Furthermore, the analysis and size characterization of a fluorescent antibody in blood plasma using AF4 are demonstrated. The results show the suitability and strength of AF4 for blood analysis and open new important routes for the analysis and characterization of therapeutic proteins in the blood.

  9. Standoff analysis of laser-produced plasmas using laser-induced fluorescence

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Harilal, S. S.; Brumfield, B. E.; Phillips, M. C.

    We report the use of laser-induced fluorescence (LIF) of laser ablation plumes for standoff applications. The standoff analysis of Al species, as major and minor species in samples, is performed in a nanosecond laser-produced plasma created at a distance ~10 m. The LIF analysis is performed by resonantly exciting an Al transition at 394.4 nm using a continuous wave (cw) tunable laser and by collecting the direct-line fluorescence signal at 396.15 nm. The spectral resolution of LIF is obtained by scanning the cw tunable LIF laser across the selected Al transition. Our results highlight that LIF provides enhanced signal intensity,more » emission persistence, and spectral resolution when compared to thermally-excited emission, and these are crucial considerations for using laser-produced plasma for standoff isotopic analysis.« less

  10. Circulating tumor DNA profiling reveals clonal evolution and real-time disease progression in advanced hepatocellular carcinoma.

    PubMed

    Cai, Zhi-Xiong; Chen, Geng; Zeng, Yong-Yi; Dong, Xiu-Qing; Lin, Min-Jie; Huang, Xin-Hui; Zhang, Da; Liu, Xiao-Long; Liu, Jing-Feng

    2017-09-01

    Circulating tumor DNA (ctDNA) provides a potential non-invasive biomarker for cancer diagnosis and prognosis, but whether it could reflect tumor heterogeneity and monitor therapeutic responses in hepatocellular carcinoma (HCC) is unclear. Focusing on 574 cancer genes known to harbor actionable mutations, we identified the mutation repertoire of HCC tissues, and monitored the corresponding ctDNA features in blood samples to evaluate its clinical significance. Analysis of 3 HCC patients' mutation profiles revealed that ctDNA could overcome tumor heterogeneity and provide information of tumor burden and prognosis. Further analysis was conducted on the 4th HCC case with multiple lesion samples and sequential plasma samples. We identified 160 subclonal SNVs in tumor tissues as well as matched peritumor tissues with PBMC as control. 96.9% of this patient's tissue mutations could be also detected in plasma samples. These subclonal SNVs were grouped into 9 clusters according to their trends of cellular prevalence shift in tumor tissues. Two clusters constituted of tumor stem somatic mutations showed circulating levels relating with cancer progression. Analysis of tumor somatic mutations revealed that circulating level of such tumor stem somatic mutations could reflect tumor burden and even predict prognosis earlier than traditional strategies. Furthermore, HCK (p.V174M), identified as a recurrent/metastatic related mutation site, could promote migration and invasion of HCC cells. Taken together, study of mutation profiles in biopsy and plasma samples in HCC patients showed that ctDNA could overcome tumor heterogeneity and real-time track the therapeutic responses in the longitudinal monitoring. © 2017 UICC.

  11. Low gas flow inductively coupled plasma optical emission spectrometry for the analysis of food samples after microwave digestion.

    PubMed

    Nowak, Sascha; Gesell, Monika; Holtkamp, Michael; Scheffer, Andy; Sperling, Michael; Karst, Uwe; Buscher, Wolfgang

    2014-11-01

    In this work, the recently introduced low flow inductively coupled plasma optical emission spectrometry (ICP-OES) with a total argon consumption below 0.7 L/min is applied for the first time to the field of food analysis. One goal is the investigation of the performance of this low flow plasma compared to a conventional ICP-OES system when non-aqueous samples with a certain matrix are introduced into the system. For this purpose, arsenic is determined in three different kinds of fish samples. In addition several nutrients (K, Na, Mg, Ca) and trace metals (Co, Cu, Mn, Cd, Pb, Zn, Fe, and Ni) are determined in honey samples (acacia) after microwave digestion. The precision of the measurements is characterized by relative standard deviations (RSD) and compared to the corresponding precision values achieved using the conventional Fassel-type torch of the ICP. To prove the accuracy of the low flow ICP-OES method, the obtained data from honey samples are validated by a conventional ICP-OES. For the measurements concerning arsenic in fish, the low flow ICP-OES values are validated by conventional Fassel-type ICP-OES. Furthermore, a certified reference material was investigated with the low gas flow setup. Limits of detection (LOD), according to the 3σ criterion, were determined to be in the low microgram per liter range for all analytes. Recovery rates in the range of 96-106% were observed for the determined trace metal elements. It was proven that the low gas flow ICP-OES leads to results that are comparable with those obtained with the Fassel-type torch for the analysis of food samples. Copyright © 2014 Elsevier B.V. All rights reserved.

  12. Evaluation of Microstructure and Mechanical Properties of Al-TiC Metal Matrix Composite Prepared by Conventional, Microwave and Spark Plasma Sintering Methods

    PubMed Central

    Ghasali, Ehsan; Fazili, Ali; Alizadeh, Masoud; Shirvanimoghaddam, Kamyar; Ebadzadeh, Touradj

    2017-01-01

    In this research, the mechanical properties and microstructure of Al-15 wt % TiC composite samples prepared by spark plasma, microwave, and conventional sintering were investigated. The sintering process was performed by the speak plasma sintering (SPS) technique, microwave and conventional furnaces at 400 °C, 600 °C, and 700 °C, respectively. The results showed that sintered samples by SPS have the highest relative density (99% of theoretical density), bending strength (291 ± 12 MPa), and hardness (253 ± 23 HV). The X-ray diffraction (XRD) investigations showed the formation of TiO2 from the surface layer decomposition of TiC particles. Scanning electron microscopy (SEM) micrographs demonstrated uniform distribution of reinforcement particles in all sintered samples. The SEM/EDS analysis revealed the formation of TiO2 around the porous TiC particles. PMID:29088114

  13. Development and Validation of an Inductively Coupled Plasma Mass Spectrometry (ICP-MS) Method for Quantitative Analysis of Platinum in Plasma, Urine, and Tissues.

    PubMed

    Zhang, Ti; Cai, Shuang; Forrest, Wai Chee; Mohr, Eva; Yang, Qiuhong; Forrest, M Laird

    2016-09-01

    Cisplatin, a platinum chemotherapeutic, is one of the most commonly used chemotherapeutic agents for many solid tumors. In this work, we developed and validated an inductively coupled plasma mass spectrometry (ICP-MS) method for quantitative determination of platinum levels in rat urine, plasma, and tissue matrices including liver, brain, lungs, kidney, muscle, heart, spleen, bladder, and lymph nodes. The tissues were processed using a microwave accelerated reaction system (MARS) system prior to analysis on an Agilent 7500 ICP-MS. According to the Food and Drug Administration guidance for industry, bioanalytical validation parameters of the method, such as selectivity, accuracy, precision, recovery, and stability were evaluated in rat biological samples. Our data suggested that the method was selective for platinum without interferences caused by other presenting elements, and the lower limit of quantification was 0.5 ppb. The accuracy and precision of the method were within 15% variation and the recoveries of platinum for all tissue matrices examined were determined to be 85-115% of the theoretical values. The stability of the platinum-containing solutions, including calibration standards, stock solutions, and processed samples in rat biological matrices was investigated. Results indicated that the samples were stable after three cycles of freeze-thaw and for up to three months. © The Author(s) 2016.

  14. Development and Validation of an Inductively Coupled Plasma Mass Spectrometry (ICP-MS) Method for Quantitative Analysis of Platinum in Plasma, Urine, and Tissues

    PubMed Central

    Zhang, Ti; Cai, Shuang; Forrest, Wai Chee; Mohr, Eva; Yang, Qiuhong; Forrest, M. Laird

    2016-01-01

    Cisplatin, a platinum chemotherapeutic, is one of the most commonly used chemotherapeutic agents for many solid tumors. In this work, we developed and validated an inductively coupled plasma mass spectrometry (ICP-MS) method for quantitative determination of platinum levels in rat urine, plasma, and tissue matrices including liver, brain, lungs, kidney, muscle, heart, spleen, bladder, and lymph nodes. The tissues were processed using a microwave accelerated reaction system (MARS) system prior to analysis on an Agilent 7500 ICP-MS. According to the Food and Drug Administration guidance for industry, bioanalytical validation parameters of the method, such as selectivity, accuracy, precision, recovery, and stability were evaluated in rat biological samples. Our data suggested that the method was selective for platinum without interferences caused by other presenting elements, and the lower limit of quantification was 0.5 ppb. The accuracy and precision of the method were within 15% variation and the recoveries of platinum for all tissue matrices examined were determined to be 85–115% of the theoretical values. The stability of the platinum-containing solutions, including calibration standards, stock solutions, and processed samples in rat biological matrices was investigated. Results indicated that the samples were stable after three cycles of freeze–thaw and for up to three months. PMID:27527103

  15. Bacterial adhesion on conventional and self-ligating metallic brackets after surface treatment with plasma-polymerized hexamethyldisiloxane.

    PubMed

    Tupinambá, Rogerio Amaral; Claro, Cristiane Aparecida de Assis; Pereira, Cristiane Aparecida; Nobrega, Celestino José Prudente; Claro, Ana Paula Rosifini Alves

    2017-01-01

    Plasma-polymerized film deposition was created to modify metallic orthodontic brackets surface properties in order to inhibit bacterial adhesion. Hexamethyldisiloxane (HMDSO) polymer films were deposited on conventional (n = 10) and self-ligating (n = 10) stainless steel orthodontic brackets using the Plasma-Enhanced Chemical Vapor Deposition (PECVD) radio frequency technique. The samples were divided into two groups according to the kind of bracket and two subgroups after surface treatment. Scanning Electron Microscopy (SEM) analysis was performed to assess the presence of bacterial adhesion over samples surfaces (slot and wings region) and film layer integrity. Surface roughness was assessed by Confocal Interferometry (CI) and surface wettability, by goniometry. For bacterial adhesion analysis, samples were exposed for 72 hours to a Streptococcus mutans solution for biofilm formation. The values obtained for surface roughness were analyzed using the Mann-Whitney test while biofilm adhesion were assessed by Kruskal-Wallis and SNK test. Significant statistical differences (p< 0.05) for surface roughness and bacterial adhesion reduction were observed on conventional brackets after surface treatment and between conventional and self-ligating brackets; no significant statistical differences were observed between self-ligating groups (p> 0.05). Plasma-polymerized film deposition was only effective on reducing surface roughness and bacterial adhesion in conventional brackets. It was also noted that conventional brackets showed lower biofilm adhesion than self-ligating brackets despite the absence of film.

  16. Single-step solubilization of milk samples with N,N-dimethylformamide for inductively coupled plasma-mass spectrometry analysis and classification based on their elemental composition.

    PubMed

    Azcarate, Silvana M; Savio, Marianela; Smichowski, Patricia; Martinez, Luis D; Camiña, José M; Gil, Raúl A

    2015-10-01

    A single-step procedure for trace elements analysis of milk samples is presented. Solubilization with small amounts of dymethylformamide (DMF) was assayed prior to inductively coupled plasma mass spectrometry (ICPMS) detection with a high efficiency sample introduction system. All main instrumental conditions were optimized in order to readily introduce the samples without matrix elimination. In order to assess and mitigate matrix effects in the determination of As, Cd, Co, Cu, Eu, Ga, Gd, Ge, Mn, Mo, Nb, Nd, Ni, Pb, Pr, Rb, Sm, S, Sr, Ta, Tb, V, Zn, and Zr, matrix matching calibration with (103)Rh as internal standard (IS) was performed. The obtained limits of detection were between 0.68 (Tb) and 30 (Zn) μg L(-1). For accuracy verification, certified Skim milk powder reference material (BCR 063R) was employed. The developed method was applied to trace elements analysis of commercially available milks. Principal components analysis was used to correlate the content of trace metals with the kind of milk, obtaining a classification according to adults, baby or baby fortified milks. The outcomes highlight a simple and fast approach that could be trustworthy for routine analysis, quality control and traceability of milks. Copyright © 2015 Elsevier B.V. All rights reserved.

  17. Design and development of a highly sensitive, field portable plasma source instrument for on-line liquid stream monitoring and real-time sample analysis

    NASA Astrophysics Data System (ADS)

    Duan, Yixiang; Su, Yongxuan; Jin, Zhe; Abeln, Stephen P.

    2000-03-01

    The development of a highly sensitive, field portable, low-powered instrument for on-site, real-time liquid waste stream monitoring is described in this article. A series of factors such as system sensitivity and portability, plasma source, sample introduction, desolvation system, power supply, and the instrument configuration, were carefully considered in the design of the portable instrument. A newly designed, miniature, modified microwave plasma source was selected as the emission source for spectroscopy measurement, and an integrated small spectrometer with a charge-coupled device detector was installed for signal processing and detection. An innovative beam collection system with optical fibers was designed and used for emission signal collection. Microwave plasma can be sustained with various gases at relatively low power, and it possesses high detection capabilities for both metal and nonmetal pollutants, making it desirable to use for on-site, real-time, liquid waste stream monitoring. An effective in situ sampling system was coupled with a high efficiency desolvation device for direct-sampling liquid samples into the plasma. A portable computer control system is used for data processing. The new, integrated instrument can be easily used for on-site, real-time monitoring in the field. The system possesses a series of advantages, including high sensitivity for metal and nonmetal elements; in situ sampling; compact structure; low cost; and ease of operation and handling. These advantages will significantly overcome the limitations of previous monitoring techniques and make great contributions to environmental restoration and monitoring.

  18. β-actin as a loading control for plasma-based Western blot analysis of major depressive disorder patients.

    PubMed

    Zhang, Rufang; Yang, Deyu; Zhou, Chanjuan; Cheng, Ke; Liu, Zhao; Chen, Liang; Fang, Liang; Xie, Peng

    2012-08-15

    Western blot analysis is a commonly used technique for determining specific protein levels in clinical samples. For normalization of protein levels in Western blot, a suitable loading control is required. On account of its relatively high and constant expression, β-actin has been widely employed in Western blot of cell cultures and tissue extracts. However, β-actin's presence in human plasma and this protein's putative role as a plasma-based loading control for Western blot analysis remain unknown. In this study, an enzyme-linked immunosorbent assay was used to determine the concentration of β-actin in human plasma, which is 6.29±0.54 ng/ml. In addition, the linearity of β-actin immunostaining and loaded protein amount was evaluated by Western blot, and a fine linearity (R²=0.974±0.012) was observed. Furthermore, the expression of plasma β-actin in major depressive disorder subjects and healthy controls was compared. The data revealed no statistically significant difference between these two groups. Moreover, the total coefficient of variation for β-actin expression in the two groups was 9.2±1.2%. These findings demonstrate that β-actin is present in human plasma and may possibly be used as a suitable loading control for plasma-based Western blot analysis in major depressive disorder. Copyright © 2012 Elsevier Inc. All rights reserved.

  19. Seminal plasma and sperm proteome of ring-tailed coatis (Nasua nasua, Linnaeus, 1766).

    PubMed

    Silva, Herlon Victor Rodrigues; Rodriguez-Villamil, Paula; Magalhães, Francisco Felipe de; Nunes, Thalles Gothardo Pereira; Freitas, Luana Azevedo de; Ribeiro, Leandro Rodrigues; Silva, Alexandre Rodrigues; Moura, Arlindo A; Silva, Lúcia Daniel Machado da

    2018-04-15

    Ring-tailed coati is listed as a species of least concern in the International Union for Conservation of Nature (IUCN) Red List, however, there has been a sharp decline in their population. The present study was conducted to evaluate the major proteins of both seminal plasma and sperm in ring-tailed coatis. Semen sample was collected from three adult coatis and evaluated for their morphological characteristics. Further, the sample was centrifuged to separate spermatozoa from seminal plasma, and then stored in liquid nitrogen. The seminal plasma and sperm proteins were subjected to one-dimensional (1-D) sodium dodecyl sulfate polyacrylamide gel electrophoresis (SDS-PAGE) and identified by mass spectrometry. Gene ontology and protein networks were analyzed using bioinformatics tools. Based on sperm concentration and average protein content of the semen, the concentration of protein/spermatozoon was found to be 104.69 ± 44.43 μg. The analysis of SDS-PAGE gels showed 20.3 ± 3.1 and 17 ± 2 protein bands/lane for seminal plasma and sperm, respectively. In-gel protein digestion and peptide analysis by mass spectrometry revealed 238 and 246 proteins in the seminal plasma and sperm, respectively. The gene ontology analysis revealed that the proteins of seminal plasma mainly participated in cellular (35%) and regulatory (21%) processes. According to their cellular localization, seminal plasma proteins were categorized as structural (18%), extracellular (17%), and nuclear (14%) proteins with molecular functions, such as catalytic activity (43%) and binding (43%). The sperm proteins were also involved in cellular (38%) and regulatory (23%) processes, and mainly categorized as extracellular (17%), nuclear (13%), and cytoplasmic (10%) proteins. The major molecular functions of the sperm proteins were catalytic activity (44%) and binding (42%). These results indicated that the seminal plasma of ring-tailed coati has an array of proteins that can potentially modulate several sperm functions, from sperm protection to oocyte binding. However, further studies are necessary to interpret the roles of these major seminal plasma proteins in coatis. Copyright © 2018 Elsevier Inc. All rights reserved.

  20. EFFECTS OF LASER RADIATION ON MATTER. LASER PLASMA: Spectral and temporal characteristics of a laser plasma

    NASA Astrophysics Data System (ADS)

    Lipchak, A. I.; Solomonov, V. I.; Tel'nov, V. A.; Osipov, V. V.

    1995-04-01

    An experimental investigation was made of the spectral and temporal characteristics of a laser plasma formed by the interaction of a CO2 laser pulse with a target in atmospheric air. The results obtained indicate that the main role in the process of filling the excited states in a laser plasma is played by a recombination cascade and that both atoms and molecules of the atmospheric gases are excited. The result also show that a laser plasma can be used in spectroscopic analysis of multicomponent samples. The solution of the thermophysical problem of heating of a target by laser radiation supports the existing ideas on the process of formation of a plasma near the target surface in air.

  1. A Simple and High-Throughput Analysis of Amatoxins and Phallotoxins in Human Plasma, Serum and Urine Using UPLC-MS/MS Combined with PRiME HLB μElution Platform

    PubMed Central

    Zhang, Shuo; Zhao, Yunfeng; Li, Haijiao; Zhou, Shuang; Chen, Dawei; Zhang, Yizhe; Yao, Qunmei; Sun, Chengye

    2016-01-01

    Amatoxins and phallotoxins are toxic cyclopeptides found in the genus Amanita and are among the predominant causes of fatal food poisoning in China. In the treatment of Amanita mushroom poisoning, an early and definite diagnosis is necessary for a successful outcome, which has prompted the development of protocols for the fast and confirmatory determination of amatoxins and phallotoxins in human biological fluids. For this purpose, a simple, rapid and sensitive multiresidue UPLC-MS/MS method for the simultaneous determination of α-amanitin, β-amanitin, γ-amanitin, phalloidin (PHD) and phallacidin (PCD) in human plasma, serum and urine was developed and validated. The diluted plasma, serum and urine samples were directly purified with a novel PRiME technique on a 96-well μElution plate platform, which allowed high-throughput sample processing and low reagent consumption. After purification, a UPLC-MS/MS analysis was performed using positive electrospray ionization (ESI+) in multiple reaction monitoring (MRM) mode. This method fulfilled the requirements of a validation test, with good results for the limit of detection (LOD), lower limit of quantification (LLOQ), accuracy, intra- and inter-assay precision, recovery and matrix effects. All of the analytes were confirmed and quantified in authentic plasma, serum and urine samples obtained from cases of poisoning using this method. Using the PRiME μElution technique for quantification reduces labor and time costs and represents a suitable method for routine toxicological and clinical emergency analysis. PMID:27153089

  2. Development of a laser ablation-hollow cathode glow discharge emission source and the application to the analysis of steel samples.

    PubMed

    Naeem, Tariq M; Matsuta, Hideyuki; Wagatsuma, Kazuaki

    2004-12-01

    A novel atomic emission spectrometry comprising laser ablation as a sampling source and hollow cathode plasma for the excitation of ablated sample atoms is proposed. In this arrangement, a conventional Grimm-type discharge lamp is employed, but the polarity of the power supply is reversed so that the cylindrical hollow tube acts as a cathode and the glow discharge plasma is produced within this tube. A laser is irradiated to introduce sample atoms into the discharge plasma. Ablated atoms are excited by collisions with electrons and gas species, and emit characteristic radiation upon de-excitation. The experiments were conducted only in an atmosphere of helium gas so as to avoid a rapid erosion of the cathode hollow tube. Phase-sensitive detection with a lock-in amplifier was utilized to reject the continuous background emission of the plasma gas and emissions of sputtered atoms from the tube material. The unique feature of this technique is that the sampling and excitation processes can be controlled independently. The proposed technique was employed for the determination of Cr, Mn, and Ni in low-alloyed steel samples. The obtained concentrations are in good agreement with the reported values. The relative standard deviation (RSD), a measure of the analytical precision, was estimated to be 2-9% for Cr, 3-4% for Mn, and 4-11% for Ni determination.

  3. Changes in plasma protein levels as an early indication of a bloodstream infection

    PubMed Central

    Joenväärä, Sakari; Kaartinen, Johanna; Järvinen, Asko; Renkonen, Risto

    2017-01-01

    Blood culture is the primary diagnostic test performed in a suspicion of bloodstream infection to detect the presence of microorganisms and direct the treatment. However, blood culture is slow and time consuming method to detect blood stream infections or separate septic and/or bacteremic patients from others with less serious febrile disease. Plasma proteomics, despite its challenges, remains an important source for early biomarkers for systemic diseases and might show changes before direct evidence from bacteria can be obtained. We have performed a plasma proteomic analysis, simultaneously at the time of blood culture sampling from ten blood culture positive and ten blood culture negative patients, and quantified 172 proteins with two or more unique peptides. Principal components analysis, Orthogonal Projections to Latent Structures Discriminant Analysis (OPLS-DA) and ROC curve analysis were performed to select protein(s) features which can classify the two groups of samples. We propose a number of candidates which qualify as potential biomarkers to select the blood culture positive cases from negative ones. Pathway analysis by two methods revealed complement activation, phagocytosis pathway and alterations in lipid metabolism as enriched pathways which are relevant for the condition. Data are available via ProteomeXchange with identifier PXD005022. PMID:28235076

  4. The low single nucleotide polymorphism heritability of plasma and saliva cortisol levels.

    PubMed

    Neumann, Alexander; Direk, Nese; Crawford, Andrew A; Mirza, Saira; Adams, Hieab; Bolton, Jennifer; Hayward, Caroline; Strachan, David P; Payne, Erin K; Smith, Jennifer A; Milaneschi, Yuri; Penninx, Brenda; Hottenga, Jouke J; de Geus, Eco; Oldehinkel, Albertine J; van der Most, Peter J; de Rijke, Yolanda; Walker, Brian R; Tiemeier, Henning

    2017-11-01

    Cortisol is an important stress hormone affected by a variety of biological and environmental factors, such as the circadian rhythm, exercise and psychological stress. Cortisol is mostly measured using blood or saliva samples. A number of genetic variants have been found to contribute to cortisol levels with these methods. While the effects of several specific single genetic variants is known, the joint genome-wide contribution to cortisol levels is unclear. Our aim was to estimate the amount of cortisol variance explained by common single nucleotide polymorphisms, i.e. the SNP heritability, using a variety of cortisol measures, cohorts and analysis approaches. We analyzed morning plasma (n=5705) and saliva levels (n=1717), as well as diurnal saliva levels (n=1541), in the Rotterdam Study using genomic restricted maximum likelihood estimation. Additionally, linkage disequilibrium score regression was fitted on the results of genome-wide association studies (GWAS) performed by the CORNET consortium on morning plasma cortisol (n=12,597) and saliva cortisol (n=7703). No significant SNP heritability was detected for any cortisol measure, sample or analysis approach. Point estimates ranged from 0% to 9%. Morning plasma cortisol in the CORNET cohorts, the sample with the most power, had a 6% [95%CI: 0-13%] SNP heritability. The results consistently suggest a low SNP heritability of these acute and short-term measures of cortisol. The low SNP heritability may reflect the substantial environmental and, in particular, situational component of these cortisol measures. Future GWAS will require very large sample sizes. Alternatively, more long-term cortisol measures such as hair cortisol samples are needed to discover further genetic pathways regulating cortisol concentrations. Copyright © 2017 Elsevier Ltd. All rights reserved.

  5. Validation of a liquid chromatography-triple quadrupole mass spectrometric method for the determination of 5-nitro-5'-hydroxy-indirubin-3'-oxime (AGM-130) in human plasma and its application to microdose clinical trial.

    PubMed

    Park, Min-Ho; Lee, Yun Young; Cho, Kyung Hee; La, Sookie; Lee, Hee Joo; Yim, Dong-Seok; Ban, Sooho; Park, Moon-Young; Kim, Yong-Chul; Kim, Yoon-Gyoon; Shin, Young G

    2016-03-01

    A liquid chromatography-triple quadrupole mass spectrometric (LC-MS/MS) method was developed and validated for the determination of 5-nitro-5'-hydroxy-indirubin-3'-oxime (AGM-130) in human plasma to support a microdose clinical trial. The method consisted of a liquid-liquid extraction for sample preparation and LC-MS/MS analysis in the positive ion mode using TurboIonSpray(TM) for analysis. d3 -AGM-130 was used as the internal standard. A linear regression (weighted 1/concentration) was used to fit calibration curves over the concentration range of 10-2000 pg/mL for AGM-130. There were no endogenous interference components in the blank human plasma tested. The accuracy at the lower limit of quantitation was 96.6% with a precision (coefficient of variation, CV) of 4.4%. For quality control samples at 30, 160 and 1600 pg/mL, the between run CV was ≤5.0 %. Between-run accuracy ranged from 98.1 to 101.0%. AGM-130 was stable in 50% acetonitrile for 168 h at 4°C and 6 h at room temperature. AGM-130 was also stable in human plasma at room temperature for 6 h and through three freeze-thaw cycles. The variability of selected samples for the incurred sample reanalysis was ≤12.7% when compared with the original sample concentrations. This validated LC-MS/MS method for determination of AGM-130 was used to support a phase 0 microdose clinical trial. Copyright © 2015 John Wiley & Sons, Ltd.

  6. Analysis of the interaction of deuterium plasmas with tungsten in the Fuego-Nuevo II device

    NASA Astrophysics Data System (ADS)

    Ramos, Gonzalo; Castillo, Fermín; Nieto, Martín; Martínez, Marco; Rangel, José; Herrera-Velázquez, Julio

    2012-10-01

    Tungsten is one of the main candidate materials for plasma-facing components in future fusion power plants. The Fuego-Nuevo II, a plasma focus device, which can produce dense magnetized helium and deuterium plasmas, has been adapted to address plasma-facing materials questions. In this paper we present results of tungsten targets exposed to deuterium plasmas in the Fuego Nuevo II device, using different experimental conditions. The plasma generated and accelerated in the coaxial gun is expected to have, before the pinch, energies of the order of hundreds eV and velocities of the order of 40,000 m s-1. At the pinch, the ions are reported to have energies of the order of 1.5 keV at most. The samples, analysed with a scanning electron microscope (SEM) in cross section show a damage profile to depths of the order of 580 nm, which are larger than those expected for ions with 1.5 keV, and may be evidence of ion acceleration. An analysis with the SRIM (Stopping Range of Ions in Matter) package calculations is shown.

  7. Uncertainty Measurement for Trace Element Analysis of Uranium and Plutonium Samples by Inductively Coupled Plasma-Atomic Emission Spectrometry (ICP-AES) and Inductively Coupled Plasma-Mass Spectrometry (ICP-MS)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gallimore, David L.

    2012-06-13

    The measurement uncertainty estimatino associated with trace element analysis of impurities in U and Pu was evaluated using the Guide to the Expression of Uncertainty Measurement (GUM). I this evalution the uncertainty sources were identified and standard uncertainties for the components were categorized as either Type A or B. The combined standard uncertainty was calculated and a coverage factor k = 2 was applied to obtain the expanded uncertainty, U. The ICP-AES and ICP-MS methods used were deveoped for the multi-element analysis of U and Pu samples. A typical analytical run consists of standards, process blanks, samples, matrix spiked samples,more » post digestion spiked samples and independent calibration verification standards. The uncertainty estimation was performed on U and Pu samples that have been analyzed previously as part of the U and Pu Sample Exchange Programs. Control chart results and data from the U and Pu metal exchange programs were combined with the GUM into a concentration dependent estimate of the expanded uncertainty. Comparison of trace element uncertainties obtained using this model was compared to those obtained for trace element results as part of the Exchange programs. This process was completed for all trace elements that were determined to be above the detection limit for the U and Pu samples.« less

  8. Pulsed microdischarge with inductively coupled plasma mass spectrometry for elemental analysis on solid metal samples.

    PubMed

    Li, Weifeng; Yin, Zhibin; Cheng, Xiaoling; Hang, Wei; Li, Jianfeng; Huang, Benli

    2015-05-05

    Pulsed microdischarge employed as source for direct solid analysis was investigated in N2 environment at atmospheric pressure. Compared with direct current (DC) microdischarge, it exhibits advantages with respect to the ablation and emission of the sample. Comprehensive evidence, including voltage-current relationship, current density (j), and electron density (ne), suggests that pulsed microdischarge is in the arc regime while DC microdischarge belongs to glow. Capability in ablating metal samples demonstrates that pulsed microdischarge is a viable option for direct solid sampling because of the enhanced instantaneous energy. Using optical spectrometer, only common emission lines of N2 can be acquired in DC mode, whereas primary atomic and ionic lines of the sample are obtained in the case of pulsed mode. Calculations show a significant difference in N2 vibrational temperatures between DC and pulsed microdischarge. Combined with inductively coupled plasma mass spectrometry (ICPMS), pulsed microdischarge exhibits much better performances in calibration linearity and limits of detection (LOD) than those of DC discharge in direct analysis of samples of different matrices. To improve transmission efficiency, a mixture of Ar and N2 was employed as discharge gas as well as carrier gas in follow-up experiments, facilitating that LODs of most elements reached ng/g.

  9. The feasibility of TEA CO2 laser-induced plasma for spectrochemical analysis of geological samples in simulated Martian conditions

    NASA Astrophysics Data System (ADS)

    Savovic, Jelena; Stoiljkovic, Milovan; Kuzmanovic, Miroslav; Momcilovic, Milos; Ciganovic, Jovan; Rankovic, Dragan; Zivkovic, Sanja; Trtica, Milan

    2016-04-01

    The present work studies the possibility of using pulsed Transversely Excited Atmospheric (TEA) carbon dioxide laser as an energy source for laser-induced breakdown spectroscopy (LIBS) analysis of rocks under simulated Martian atmospheric conditions. Irradiation of a basaltic rock sample with the laser intensity of 56 MW cm- 2, in carbon-dioxide gas at a pressure of 9 mbar, created target plasma with favorable conditions for excitation of all elements usually found in geological samples. Detection limits of minor constituents (Ba, Cr, Cu, Mn, Ni, Sr, V, and Zr) were in the 3 ppm-30 ppm range depending on the element. The precision varied between 5% and 25% for concentration levels of 1% to 10 ppm, respectively. Generally, the proposed relatively simple TEA CO2 laser-LIBS system provides good sensitivity for geological studies under reduced CO2 pressure.

  10. Theoretical and experimental analysis of analyte transport in a fiber-optic, protein C immuno-biosensor.

    PubMed

    Tang, Liang; Kwon, Hyun J; Kang, Kyung A

    2004-12-30

    Protein C (PC) is an important anticoagulant in human blood plasma, and early diagnosis of PC deficiency is critical for preventing dangerous thromboembolic complications. A fiber-optic PC immuno-biosensor has been under development in our research group for real-time PC-deficiency diagnosis. The sensor has demonstrated a good sensitivity and specificity for quantifying PC in buffered solutions. However, for plasma samples, with a limited sample reaction time, the sensor produced only 30% of the signal intensity of PC in buffer. The high plasma viscosity (1.9 cP) was speculated as the major reason for signal intensity reduction. In this investigation, the sensing performance of the fiber-optic PC biosensor is systematically characterized in terms of physical and chemical properties of the sample media. Theoretical and experimental analyses indicate that the reduced diffusion rate of PC molecules in viscous samples caused the sensing system to be more mass-transfer-limited. Convective flow of sample/reagent solutions during immunoreactions can increase the rate of the analyte mass transport from the bulk solution to the sensor surface, with reaction kinetics changing from mass-transfer-limited to reaction-limited as flow velocity increases. It was shown that PC sensor performance was significantly improved for plasma samples with convection. The effect of the flow velocity and incubation times for samples and reagents on the sensor performance was also systematically analyzed to optimize the assay protocol for PC sensing. Currently, a 6-cm-long immuno-biosensor is capable of quantifying PC in plasma (1 mL) in the heterozygous PC deficiency range (0.5 to 2.5 microg/mL) within 5 minutes, at an average signal-to-noise ratio of 50. 2004 Wiley Periodicals, Inc.

  11. Impression of plasma voltage on growth of α-V2O5 nanostructured thin films

    NASA Astrophysics Data System (ADS)

    Sharma, Rabindar Kumar; Kumar, Prabhat; Reddy, G. B.

    2015-06-01

    In this communication, we synthesized vanadium pentoxide (α-V2O5) nanostructured thin films (NSTs) accompanied with nanoflakes/ nanoplates on the Ni-coated glass substrates employing plasma assisted sublimation process (PASP) as a function of plasma voltage (Vp). The effect of plasma voltage on structural, morphological, compositional, and vibrational properties have been studied systematically. The structural analysis divulged that all films deposited at different Vp have pure orthorhombic phase, no impurity phase is detected under resolution limit of XRD and XPS. The morphological studies of samples is carried out by SEM, revealed that features as well as alignment of V2O5 NSTs is greatly monitored by Vp and the film possessing the best features is obtained at 2500volt. In addition, XPS results reveal that V5+ oxidation state is the most prominent state in sample V2, which represents better stoichiometric nature of film. The vibrational study of all samples is performed by FTIR and strongly support the XRD observations. All the results are in consonance with each other.

  12. Application of DBS sampling in combination with LC-MS/MS for pharmacokinetic evaluation of a compound with species-specific blood-to-plasma partitioning.

    PubMed

    Xu, Guifen; Chen, Jiyun S; Phadnis, Ruta; Huang, Tom; Uyeda, Craig; Soto, Marcus; Stouch, Brian; Wells, Mary C; James, Christopher A; Carlson, Timothy J

    2012-08-01

    Dried blood spot (DBS) sampling in combination with LC-MS/MS has been used increasingly in drug discovery for quantitative analysis to support pharmacokinetic (PK) studies. In this study, we assessed the effect of blood-to-plasma (B:P) partitioning on the bioanalytical performance and PK data acquired by DBS for a compound AMG-1 with species and concentration-dependent B:P ratio. B:P partitioning did not adversely affect bioanalytical performance of DBS for AMG-1. For rat, (B:P ratio of 0.63), PK profiles from DBS and plasma methods were comparable. For dog, concentration-dependence of B:P ratio was observed both in vivo and in vitro. Additional studies demonstrated concentration-dependence of the compound's unbound fraction in plasma, which may contribute to the concentration-dependence of the B:P ratio. DBS is a promising sampling technique for preclinical pharmacokinetic studies. For compounds with high B:P ratio, caution needs to be applied for data comparison and interpretation between matrices.

  13. Detection of tetracosactide in plasma by enzyme-linked immunosorbent assay (ELISA).

    PubMed

    Martin, Laurent; Chaabo, Ayman; Lasne, Françoise

    2015-06-01

    As a synthetic analogue of adrenocorticotropic hormone (ACTH), tetracosactide is prohibited in sport by the World Anti-Doping Agency (WADA). An enzyme-linked immunosorbent assay (ELISA) method is proposed for detection of this drug in plasma. Since its structure corresponds to the 24 N-terminal of the 39 amino acids of the natural endogenous peptide ACTH, tetracosactide can be detected with a commercial ELISA kit for ACTH that uses antibodies, the epitopes of which are located in the 1-24 part of ACTH. However, an essential condition for detection specificity is the preliminary total clearance of endogenous ACTH in the plasma samples. This is achieved by a preparative step based on cation-exchange chromatography before ELISA. The method is specific and sensitive (LOD: 30 pg/mL) and may be used as a screening analysis in anti-doping control. The pre-analytical conditions are shown to be of the upmost importance and recommendations for blood collection (EDTA tubes), sample transport (4 °C) and plasma sample storage (-20 °C) are presented. Copyright © 2014 John Wiley & Sons, Ltd.

  14. Spectral characteristics of plasma sheet ion and electron populations during undisturbed geomagnetic conditions

    NASA Technical Reports Server (NTRS)

    Christon, S. P.; Williams, D. J.; Mitchell, D. G.; Frank, L. A.; Huang, C. Y.

    1989-01-01

    The spectral characteristics of plasma-sheet ion and electron populations during periods of low geomagnetic activity were determined from the analysis of 127 one-hour average samples of central plasma sheet ions and electrons. Particle data from the ISEE-1 low-energy proton and electron differential energy analyzer and medium-energy particle instrument were combined to obtain differential energy spectra in the plasma sheet at geocentric radial distances above 12 earth radii. The relationships between the ion and electron spectral shapes and between the spectral shapes and the geomagnetic activity index were statistically investigated. It was found that the presence of interplanetary particle fluxes does not affect the plasma sheet particle spectral shape.

  15. High-Throughput Quantitative Lipidomics Analysis of Nonesterified Fatty Acids in Human Plasma.

    PubMed

    Christinat, Nicolas; Morin-Rivron, Delphine; Masoodi, Mojgan

    2016-07-01

    We present a high-throughput, nontargeted lipidomics approach using liquid chromatography coupled to high-resolution mass spectrometry for quantitative analysis of nonesterified fatty acids. We applied this method to screen a wide range of fatty acids from medium-chain to very long-chain (8 to 24 carbon atoms) in human plasma samples. The method enables us to chromatographically separate branched-chain species from their straight-chain isomers as well as separate biologically important ω-3 and ω-6 polyunsaturated fatty acids. We used 51 fatty acid species to demonstrate the quantitative capability of this method with quantification limits in the nanomolar range; however, this method is not limited only to these fatty acid species. High-throughput sample preparation was developed and carried out on a robotic platform that allows extraction of 96 samples simultaneously within 3 h. This high-throughput platform was used to assess the influence of different types of human plasma collection and preparation on the nonesterified fatty acid profile of healthy donors. Use of the anticoagulants EDTA and heparin has been compared with simple clotting, and only limited changes have been detected in most nonesterified fatty acid concentrations.

  16. Rapid measurement of plasma free fatty acid concentration and isotopic enrichment using LC/MS

    PubMed Central

    Persson, Xuan-Mai T.; Błachnio-Zabielska, Agnieszka Urszula; Jensen, Michael D.

    2010-01-01

    Measurements of plasma free fatty acids (FFA) concentration and isotopic enrichment are commonly used to evaluate FFA metabolism. Until now, gas chromatography-combustion-isotope ratio mass spectrometry (GC/C/IRMS) was the best method to measure isotopic enrichment in the methyl derivatives of 13C-labeled fatty acids. Although IRMS is excellent for analyzing enrichment, it requires time-consuming derivatization steps and is not optimal for measuring FFA concentrations. We developed a new, rapid, and reliable method for simultaneous quantification of 13C-labeled fatty acids in plasma using high-performance liquid chromatography-mass spectrometry (HPLC/MS). This method involves a very quick Dole extraction procedure and direct injection of the samples on the HPLC system. After chromatographic separation, the samples are directed to the mass spectrometer for electrospray ionization (ESI) and analysis in the negative mode using single ion monitoring. By employing equipment with two columns connected parallel to a mass spectrometer, we can double the throughput to the mass spectrometer, reducing the analysis time per sample to 5 min. Palmitate flux measured using this approach agreed well with the GC/C/IRMS method. This HPLC/MS method provides accurate and precise measures of FFA concentration and enrichment. PMID:20526002

  17. Advantages of automation in plasma sample preparation prior to HPLC/MS/MS quantification: application to the determination of cilazapril and cilazaprilat in a bioequivalence study.

    PubMed

    Kolocouri, Filomila; Dotsikas, Yannis; Apostolou, Constantinos; Kousoulos, Constantinos; Soumelas, Georgios-Stefanos; Loukas, Yannis L

    2011-01-01

    An HPLC/MS/MS method characterized by complete automation and high throughput was developed for the determination of cilazapril and its active metabolite cilazaprilat in human plasma. All sample preparation and analysis steps were performed by using 2.2 mL 96 deep-well plates, while robotic liquid handling workstations were utilized for all liquid transfer steps, including liquid-liquid extraction. The whole procedure was very fast compared to a manual procedure with vials and no automation. The method also had a very short chromatographic run time of 1.5 min. Sample analysis was performed by RP-HPLC/MS/MS with positive electrospray ionization using multiple reaction monitoring. The calibration curve was linear in the range of 0.500-300 and 0.250-150 ng/mL for cilazapril and cilazaprilat, respectively. The proposed method was fully validated and proved to be selective, accurate, precise, reproducible, and suitable for the determination of cilazapril and cilazaprilat in human plasma. Therefore, it was applied to a bioequivalence study after per os administration of 2.5 mg tablet formulations of cilazapril.

  18. The effect of chronic prostatitis on zinc concentration of prostatic fluid and seminal plasma: a systematic review and meta-analysis.

    PubMed

    Cui, Dong; Han, GuangWei; Shang, YongGang; Mu, LiJun; Long, QingZhi; Du, YueFeng

    2015-01-01

    Prostatitis is a common disease in urology departments. Prostatic zinc accumulation is connected with the secretory function of the prostate, and zinc concentrations present in prostatic diseases differ greatly from the normal level. Studies have investigated the effect of chronic prostatitis on zinc concentration of prostatic fluid and seminal plasma, but have shown inconsistent results. Hence, we performed a systematic literature review and meta-analysis to assess the effect of chronic prostatitis on the zinc concentration of prostatic fluid and seminal plasma. Systematic literature searches were conducted with PubMed, Embase, Science Direct/Elsevier, CNKI and the Cochrane Library up to March 2015 for case-control studies that involved the relationship between chronic prostatitis and zinc concentration of prostatic fluid and seminal plasma. Meta-analysis was performed with Review Manager and Stata software. Standard mean differences (SMDs) of zinc concentration were identified with 95% confidence intervals (95% CIs) in a random- or fixed-effects model. Our results illustrated that the zinc concentrations in prostatic fluid and seminal plasma from chronic prostatitis patients were significantly lower than normal controls (SMD [95% CI] -246.71 [-347.97, -145.44], -20.74 [-35.11, -6.37], respectively). The sample size of each study was relatively small, and a total of 731 chronic prostatitis patients and 574 normal controls were investigated in all fourteen studies. Several studies related to the subject were excluded due to lack of control data or means and standard deviations. The present study illustrates that there was a significant negative effect of chronic prostatitis on zinc concentrations of prostatic fluid and seminal plasma. Further studies with larger sample sizes are needed to better illuminate the negative impact of chronic prostatitis on zinc concentrations.

  19. High-throughput and simultaneous analysis of eight central-acting muscle relaxants in human plasma by ultra-performance liquid chromatography-tandem mass spectrometry in the positive and negative ionization modes.

    PubMed

    Ogawa, Tadashi; Hattori, Hideki; Kaneko, Rina; Ito, Kenjiro; Iwai, Masae; Mizutani, Yoko; Arinobu, Tetsuya; Ishii, Akira; Seno, Hiroshi

    2011-06-01

    In this report, a high-throughput and sensitive method for analysis of eight central-acting muscle relaxants in human plasma by ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) in the positive and negative ionization modes using tolbutamide as internal standard is presented. After pretreatment of a plasma sample by solid-phase extraction with an Oasis HLB cartridge, muscle relaxants were analyzed by UPLC with Acquity UPLC BEH C(18) column and Acquity TQD tandem quadrupole mass spectrometer equipped with an electrospray ionization interface. The calibration curves for muscle relaxants spiked into human plasma equally showed good linearities in the nanogram per milliliter order range. The detection limits (signal-to-noise ratio = 3) was as low as 0.1-2 ng/mL. The method gave satisfactory recovery rates, accuracy, and precision for quality control samples spiked with muscle relaxants. To further validate the present method, 250 mg of chlorphenesin carbamate was orally administered to a healthy male volunteer, and the concentrations of chlorphenesin carbamate in plasma were measured 0.5, 1, 2, 4, 6, and 8 h after dosing; their concentrations in human plasma were between 0.62 and 2.44 μg/mL. To our knowledge, this is the first report describing simultaneous analysis of over more than two central-acting muscle relaxants by liquid chromatography-tandem mass spectrometry. This has been realized by the capability of our instrument for simultaneous multiple reaction monitoring of the target compounds in both positive and negative ionization modes. Therefore, the present method seems very useful in forensic and clinical toxicology and pharmacokinetic studies.

  20. Evaluating the effect of sample type on American alligator ( Alligator mississippiensis) analyte values in a point-of-care blood analyser

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hamilton, Matthew T.; Finger, John W.; Winzeler, Megan E.

    The assessment of wildlife health has been enhanced by the ability of point-of-care (POC) blood analysers to provide biochemical analyses of non-domesticated animals in the field. However, environmental limitations (e.g. temperature, atmospheric humidity and rain) and lack of reference values may inhibit researchers from using such a device with certain wildlife species. Evaluating the use of alternative sample types, such as plasma, in a POC device may afford researchers the opportunity to delay sample analysis and the ability to use banked samples. In this study, we examined fresh whole blood, fresh plasma and frozen plasma (sample type) pH, partial pressuremore » of carbon dioxide (PCO 2), bicarbonate (HCO 3₋), total carbon dioxide (TCO 2), base excess (BE), partial pressure of oxygen (PO 2), oxygen saturation (sO 2) and lactate concentrations in 23 juvenile American alligators (Alligator mississippiensis) using an i-STAT CG4+ cartridge. Our results indicate that sample type had no effect on lactate concentration values (F 2,65 = 0.37, P = 0.963), suggesting that the i-STAT analyser can be used reliably to quantify lactate concentrations in fresh and frozen plasma samples. In contrast, the other seven blood parameters measured by the CG4+ cartridge were significantly affected by sample type. In conclusion, we were able to collect blood samples from all alligators within 2 min of capture to establish preliminary reference ranges for juvenile alligators based on values obtained using fresh whole blood.« less

  1. Evaluating the effect of sample type on American alligator (Alligator mississippiensis) analyte values in a point-of-care blood analyser

    PubMed Central

    Hamilton, Matthew T.; Finger, John W.; Winzeler, Megan E.; Tuberville, Tracey D.

    2016-01-01

    The assessment of wildlife health has been enhanced by the ability of point-of-care (POC) blood analysers to provide biochemical analyses of non-domesticated animals in the field. However, environmental limitations (e.g. temperature, atmospheric humidity and rain) and lack of reference values may inhibit researchers from using such a device with certain wildlife species. Evaluating the use of alternative sample types, such as plasma, in a POC device may afford researchers the opportunity to delay sample analysis and the ability to use banked samples. In this study, we examined fresh whole blood, fresh plasma and frozen plasma (sample type) pH, partial pressure of carbon dioxide (PCO2), bicarbonate (HCO3−), total carbon dioxide (TCO2), base excess (BE), partial pressure of oxygen (PO2), oxygen saturation (sO2) and lactate concentrations in 23 juvenile American alligators (Alligator mississippiensis) using an i-STAT CG4+ cartridge. Our results indicate that sample type had no effect on lactate concentration values (F2,65 = 0.37, P = 0.963), suggesting that the i-STAT analyser can be used reliably to quantify lactate concentrations in fresh and frozen plasma samples. In contrast, the other seven blood parameters measured by the CG4+ cartridge were significantly affected by sample type. Lastly, we were able to collect blood samples from all alligators within 2 min of capture to establish preliminary reference ranges for juvenile alligators based on values obtained using fresh whole blood. PMID:27382469

  2. Evaluating the effect of sample type on American alligator ( Alligator mississippiensis) analyte values in a point-of-care blood analyser

    DOE PAGES

    Hamilton, Matthew T.; Finger, John W.; Winzeler, Megan E.; ...

    2016-01-01

    The assessment of wildlife health has been enhanced by the ability of point-of-care (POC) blood analysers to provide biochemical analyses of non-domesticated animals in the field. However, environmental limitations (e.g. temperature, atmospheric humidity and rain) and lack of reference values may inhibit researchers from using such a device with certain wildlife species. Evaluating the use of alternative sample types, such as plasma, in a POC device may afford researchers the opportunity to delay sample analysis and the ability to use banked samples. In this study, we examined fresh whole blood, fresh plasma and frozen plasma (sample type) pH, partial pressuremore » of carbon dioxide (PCO 2), bicarbonate (HCO 3₋), total carbon dioxide (TCO 2), base excess (BE), partial pressure of oxygen (PO 2), oxygen saturation (sO 2) and lactate concentrations in 23 juvenile American alligators (Alligator mississippiensis) using an i-STAT CG4+ cartridge. Our results indicate that sample type had no effect on lactate concentration values (F 2,65 = 0.37, P = 0.963), suggesting that the i-STAT analyser can be used reliably to quantify lactate concentrations in fresh and frozen plasma samples. In contrast, the other seven blood parameters measured by the CG4+ cartridge were significantly affected by sample type. In conclusion, we were able to collect blood samples from all alligators within 2 min of capture to establish preliminary reference ranges for juvenile alligators based on values obtained using fresh whole blood.« less

  3. Preanalytical blood sample workup for cell-free DNA analysis using Droplet Digital PCR for future molecular cancer diagnostics.

    PubMed

    van Ginkel, Joost H; van den Broek, Daan A; van Kuik, Joyce; Linders, Dorothé; de Weger, Roel; Willems, Stefan M; Huibers, Manon M H

    2017-10-01

    In current molecular cancer diagnostics, using blood samples of cancer patients for the detection of genetic alterations in plasma (cell-free) circulating tumor DNA (ctDNA) is an emerging practice. Since ctDNA levels in blood are low, highly sensitive Droplet Digital PCR (ddPCR) can be used for detecting rare mutational targets. In order to perform ddPCR on blood samples, a standardized procedure for processing and analyzing blood samples is necessary to facilitate implementation into clinical practice. Therefore, we assessed the technical sample workup procedure for ddPCR on blood plasma samples. Blood samples from healthy individuals, as well as lung cancer patients were analyzed. We compared different methods and protocols for sample collection, storage, centrifugation, isolation, and quantification. Cell-free DNA (cfDNA) concentrations of several wild-type targets and BRAF and EGFR-mutant ctDNA concentrations quantified by ddPCR were primary outcome measurements. Highest cfDNA concentrations were measured in blood collected in serum tubes. No significant differences in cfDNA concentrations were detected between various time points of up to 24 h until centrifugation. Highest cfDNA concentrations were detected after DNA isolation with the Quick cfDNA Serum & Plasma Kit, while plasma isolation using the QIAamp Circulating Nucleic Acid Kit yielded the most consistent results. DdPCR results on cfDNA are highly dependent on multiple factors during preanalytical sample workup, which need to be addressed during the development of this diagnostic tool for cancer diagnostics in the future. © 2017 The Authors. Cancer Medicine published by John Wiley & Sons Ltd.

  4. Development and validation of a new method to simultaneously quantify triazoles in plasma spotted on dry sample spot devices and analysed by HPLC-MS.

    PubMed

    Baietto, Lorena; D'Avolio, Antonio; Marra, Cristina; Simiele, Marco; Cusato, Jessica; Pace, Simone; Ariaudo, Alessandra; De Rosa, Francesco Giuseppe; Di Perri, Giovanni

    2012-11-01

    Therapeutic drug monitoring (TDM) of triazoles is widely used in clinical practice to optimize therapy. TDM is limited by technical problems and cost considerations, such as sample storage and dry-ice shipping. We aimed to develop and validate a new method to analyse itraconazole, posaconazole and voriconazole in plasma spotted on dry sample spot devices (DSSDs) and to quantify them by an HPLC system. Extraction from DSSDs was done using n-hexane/ethyl acetate and ammonia solution. Samples were analysed using HPLC with mass spectrometry (HPLC-MS). Accuracy and precision were assayed by inter- and intra-day validation. The stability of triazoles in plasma spotted on DSSDs was investigated at room temperature for 1 month. The method was compared with a validated standard HPLC method for quantification of triazoles in human plasma. Mean inter- and intra-day accuracy and precision were <15% for all compounds. Triazoles were stable for 2 weeks at room temperature. The method was linear (r(2) > 0.999) in the range 0.031-8 mg/L for itraconazole and posaconazole, and 0.058-15 mg/L for voriconazole. High sensitivity was observed; limits of detection were 0.008, 0.004 and 0.007 mg/L for itraconazole, posaconazole and voriconazole, respectively. A high degree of correlation (r(2) > 0.94) was obtained between the DSSD method and the standard method of analysis. The method that we developed and validated to quantify triazoles in human plasma spotted on DSSDs is accurate and precise. It overcomes problems related to plasma sample storage and shipment, allowing TDM to be performed in a cheaper and safer manner.

  5. Vitamins D and A can be successfully measured by LC-MS/MS in cord blood diluted plasma.

    PubMed

    Albarhani, Ali A; Collier, Fiona; Greaves, Ronda F; Ponsonby, Anne-Louise; Allen, Katrina J; Vuillermin, Peter J; Roche, Peter; Clarke, Michael W

    2015-11-01

    In widely used protocols for the collection and isolation of cord blood mononuclear cells, investigators are left with substantial volumes of diluted plasma which could be used for other measurements. The aim of this study was to ascertain the validity of umbilical cord blood (UCB) diluted plasma samples for vitamin D, A and E analysis compared to UCB serum samples. Twenty UCB matched samples of diluted plasma and serum were collected. The samples were analysed by two liquid chromatography-tandem mass spectrometry (LC-MS/MS) methods on two separate occasions. The results of 25(OH)D3 obtained by the two laboratories demonstrated close agreement with a mean difference of 0.14nmol/L [95% confidence interval (95% CI), -6.8 to 7.1]. Both methods demonstrate close agreement for 25(OH)D3 in UCB serum versus diluted UCB plasma; mean difference 2.2nmol/L [95% CI, -9.5 to 13.9] and 4.1nmol/L [95% CI, -14.5 to 6.1] for the results from Lab A and Lab B, respectively. Vitamin A was quantified by Lab A in UCB serum and diluted UCB plasma; mean difference 0.07μmol/L [95% CI, -0.41 to 0.28]. Results of 25(OH)D3 epimer and vitamin E in the diluted UCB plasma were below the limit of quantification, and could not be compared with UCB serum. Diluted UCB plasma can be used for the quantification of retinol and 25(OH)D3 by LC-MS/MS. By contrast, quantification of 25(OH)D3 epimer and vitamin E in diluted UCB plasma is not supported by this study due to limitations in analytical sensitivity. Copyright © 2015 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  6. Polymer monolithic capillary microextraction combined on-line with inductively coupled plasma MS for the determination of trace rare earth elements in biological samples.

    PubMed

    Zhang, Lin; Chen, Beibei; He, Man; Hu, Bin

    2013-07-01

    A rapid and sensitive method based on polymer monolithic capillary microextraction combined on-line with microconcentric nebulization inductively coupled plasma MS has been developed for the determination of trace/ultratrace rare earth elements in biological samples. For this purpose, the iminodiacetic acid modified poly(glycidyl methacrylate-trimethylolpropane trimethacrylate) monolithic capillary was prepared and characterized by SEM and FTIR spectroscopy. Factors affecting the extraction efficiency, such as sample pH, sample flow rate, sample/eluent volume, and coexisting ions were investigated in detail. Under the optimal conditions, the LODs for rare earth elements were in the range of 0.08 (Er) to 0.97 ng/L (Nd) with a sampling frequency of 8.5 h(-1), and the RSDs were between 1.5% (Sm) and 7.4% (Nd) (c = 20 ng/L, n = 7). The proposed method was successfully applied to the analysis of trace/ultratrace rare earth elements in human urine and serum samples, and the recoveries for the spiked samples were in the range of 82-105%. The developed method was simple, rapid, sensitive, and favorable for the analysis of trace/ultratrace rare earth elements in biological samples with limited sample volume. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. Laboratory heterogeneity of the lupus anticoagulant: a multicentre study using different clotting assays on a panel of 78 samples. Hemostasis Committee of the "Société Française de Biologie Clinique".

    PubMed

    1992-05-15

    The laboratory heterogeneity of the lupus anticoagulant (LA) was investigated in a multicentre study using a panel of 78 plasma samples diagnosed as containing a LA. Consecutive samples were collected by 12 participants using various screening tests, and sent to 7 laboratories which performed one or more clotting assays among the following: activated partial thromboplastin time (APTT), dilute Russell viper venom time, kaolin clotting time (KCT), dilute tissue thromboplastin time (dTTI) and a platelet neutralization test. For APTT and dTTI, 10 versions of these tests including standard and mixing procedures were carried out. They varied by reagents, phospholipid concentration or methodology. Cut-off times were determined for each test by comparing the results of the panel to those of a control population. When the data of all clotting assays were pooled, 70 of the 78 selected plasmas were considered to contain LA, 15 of them having a low-titer inhibitor. Sensitivity, defined as the proportion of positive results among LA-containing plasmas, varied from 62 to 100% and was positively related to responsiveness (defined as the mean ratio of clotting time to cut-off time). Laboratory heterogeneity of LA-containing plasma was illustrated by a star symbol plot analysis. Different populations of samples, with LA preferentially recognized by one assay (or group of assays) irrespective of the overall sensitivity of this assay, were identified. Multiple component analysis demonstrated the heterogeneity of low-titer inhibitors, which complicates their recognition in routine laboratory investigation.

  8. Rapid and sensitive determination of tellurium in soil and plant samples by sector-field inductively coupled plasma mass spectrometry.

    PubMed

    Yang, Guosheng; Zheng, Jian; Tagami, Keiko; Uchida, Shigeo

    2013-11-15

    In this work, we report a rapid and highly sensitive analytical method for the determination of tellurium in soil and plant samples using sector field inductively coupled plasma mass spectrometry (SF-ICP-MS). Soil and plant samples were digested using Aqua regia. After appropriate dilution, Te in soil and plant samples was directly analyzed without any separation and preconcentration. This simple sample preparation approach avoided to a maximum extent any contamination and loss of Te prior to the analysis. The developed analytical method was validated by the analysis of soil/sediment and plant reference materials. Satisfactory detection limits of 0.17 ng g(-1) for soil and 0.02 ng g(-1) for plant samples were achieved, which meant that the developed method was applicable to studying the soil-to-plant transfer factor of Te. Our work represents for the first time that data on the soil-to-plant transfer factor of Te were obtained for Japanese samples which can be used for the estimation of internal radiation dose of radioactive tellurium due to the Fukushima Daiichi Nuclear Power Plant accident. Copyright © 2013 Elsevier B.V. All rights reserved.

  9. Reference intervals for plasma-free amino acid in a Japanese population.

    PubMed

    Yamamoto, Hiroyuki; Kondo, Kazuhiro; Tanaka, Takayuki; Muramatsu, Takahiko; Yoshida, Hiroo; Imaizumi, Akira; Nagao, Kenji; Noguchi, Yasushi; Miyano, Hiroshi

    2016-05-01

    Plasma amino acid concentrations vary with various diseases. Although reference intervals are useful in daily clinical practice, no reference intervals have been reported for plasma amino acids in a large Japanese population. Reference individuals were selected from 7685 subjects examined with the Japanese Ningen Dock in 2008. A total of 1890 individuals were selected based on exclusion criteria, and the reference samples were selected after the outlier samples for each amino acid concentration were excluded. The lower limit of the reference intervals for the plasma amino acid concentrations was set at the 2.5th percentile and the upper limit at the 97.5th percentile. By use of the nested analysis of variance, we analysed a large dataset of plasma samples and the effects of background factors (sex, age and body mass index [BMI]) on the plasma amino acid concentrations. Most amino acid concentrations were related to sex, especially those of branched-chained amino acid. The citrulline, glutamine, ornithine and lysine concentrations were related to age. The glutamate concentration was related to body mass index. The concentrations of most amino acids are more strongly related to sex than to age or body mass index. Our results indicate that the reference intervals for plasma amino acid concentrations should be stratified by sex when the background factors of age and body mass index are considered. © The Author(s) 2015 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  10. Cloud-point extraction is compatible with liquid chromatography coupled to electrospray ionization mass spectrometry for the determination of antazoline in human plasma.

    PubMed

    Giebułtowicz, Joanna; Kojro, Grzegorz; Piotrowski, Roman; Kułakowski, Piotr; Wroczyński, Piotr

    2016-09-05

    Cloud-point extraction (CPE) is attracting increasing interest in a number of analytical fields, including bioanalysis, as it provides a simple, safe and environmentally-friendly sample preparation technique. However, there are only few reports on the application of this extraction technique in liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI-MS/MS) analysis. In this study, CPE was used for the isolation of antazoline from human plasma. To date, only one method of antazoline isolation from plasma exists-liquid-liquid extraction (LLE). The aim of this study was to prove the compatibility of CPE and LC-ESI-MS/MS and the applicability of CPE to the determination of antazoline in spiked human plasma and clinical samples. Antazoline was isolated from human plasma using Triton X-114 as a surfactant. Xylometazoline was used as an internal standard. NaOH concentration, temperature and Triton X-114 concentration were optimized. The absolute matrix effect was carefully investigated. All validation experiments met international acceptance criteria and no significant relative matrix effect was observed. The compatibility of CPE and LC-ESI-MS/MS was confirmed using clinical plasma samples. The determination of antazoline concentration in human plasma in the range 10-2500ngmL(-1) by the CPE method led to results which are equivalent to those obtained by the widely used liquid-liquid extraction method. Copyright © 2016 Elsevier B.V. All rights reserved.

  11. Liquid biopsy - Performance of the PAXgene® Blood ccfDNA Tubes for the isolation and characterization of cell-free plasma DNA from tumor patients.

    PubMed

    Schmidt, Bernd; Reinicke, Dana; Reindl, Iris; Bork, Ines; Wollschläger, Bettina; Lambrecht, Nina; Fleischhacker, Michael

    2017-06-01

    In most research laboratories the use of EDTA tubes for the isolation of plasma DNA from tumor patients is standard. Unfortunately these tubes do not allow for an extended storage of samples before processing and prevent EDTA tubes from being shipped at ambient temperature. The aim of our study was to compare the quantity and quality of plasma DNA isolated from EDTA and PAXgene® Blood ccfDNA Tubes in different downstream applications. We enrolled 29 patients in our study. Blood samples were drawn into EDTA and PAXgene® Blood ccfDNA Tubes and were processed on day 0 and day 7 after storage at ambient temperature. The plasma DNA from 10 patients was isolated manually. For the DNA isolation from the plasma of 19 additional patients we used the automated QIAsymphony system. The total amount DNA from all samples was measured with a quantitative real-time PCR assay. In addition the amount of methylated mSHOX2 plasma DNA was determined. While the 7day storage lead to an increased amount of total DNA in almost all EDTA tubes, this effect was only seen in very few PAXgene® Blood ccfDNA Tubes. The stabilization solution which prevents the lysis of blood cells had no effect on the method for quantification of methylated sequences in these samples. The quantity and quality of plasma DNA from both types of blood draw tubes are comparable. DNA from PAXgene® Blood ccfDNA was successfully used for PCR-based quantification of total amount of cell-free DNA and for methylation analysis as well. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. Toward the automated analysis of plasma physics problems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mynick, H.E.

    1989-04-01

    A program (CALC) is described, which carries out nontrivial plasma physics calculations, in a manner intended to emulate the approach of a human theorist. This includes the initial process of gathering the relevant equations from a plasma knowledge base, and then determining how to solve them. Solution of the sets of equations governing physics problems, which in general have a nonuniform,irregular structure, not amenable to solution by standardized algorithmic procedures, is facilitated by an analysis of the structure of the equations and the relations among them. This often permits decompositions of the full problem into subproblems, and other simplifications inmore » form, which renders the resultant subsystems soluble by more standardized tools. CALC's operation is illustrated by a detailed description of its treatment of a sample plasma calculation. 5 refs., 3 figs.« less

  13. Analysis of iodinated X-ray contrast agents in water samples by ion chromatography and inductively-coupled plasma mass spectrometry.

    PubMed

    Sacher, Frank; Raue, Brigitte; Brauch, Heinz-Jürgen

    2005-08-26

    In this paper, an analytical method for the determination of six iodinated X-ray contrast agents (amidotrizoic acid, iohexol, iomeprol, iopamidol, iopromide, and ioxitalamic acid), iodide, and iodate in water samples is presented. The method is based on a separation of the analytes by ion chromatography (IC) and a subsequent detection by inductively-coupled plasma mass spectrometry (ICP-MS). The method was optimised with respect to separation conditions (column type and eluent composition) and extensively validated. Without pre-concentration of the samples, limits of detection below 0.2 microg/l could be achieved whereby reproducibility was below 6% for all compounds under investigation.

  14. Meticulous plasma isolation is essential to avoid false low-level viraemia in Roche Cobas HIV-1 viral load assays.

    PubMed

    Mortier, Virginie; Vancoillie, Leen; Dauwe, Kenny; Staelens, Delfien; Demecheleer, Els; Schauvliege, Marlies; Dinakis, Sylvie; Van Maerken, Tom; Dessilly, Géraldine; Ruelle, Jean; Verhofstede, Chris

    2017-10-24

    Pre-analytical sample processing is often overlooked as a potential cause of inaccurate assay results. Here we demonstrate how plasma, extracted from standard EDTA-containing blood collection tubes, may contain traces of blood cells consequently resulting in a false low-level HIV-1 viral load when using Roche Cobas HIV-1 assays. The presence of human DNA in Roche Cobas 4800 RNA extracts and in RNA extracts from the Abbott HIV-1 RealTime assay was assessed by quantifying the human albumin gene by means of quantitative PCR. RNA was extracted from plasma samples before and after an additional centrifugation and tested for viral load and DNA contamination. The relation between total DNA content and viral load was defined. Elevated concentrations of genomic DNA were detected in 28 out of 100 Cobas 4800 extracts and were significantly more frequent in samples processed outside of the AIDS Reference Laboratory. An association between genomic DNA presence and spurious low-level viraemia results was demonstrated. Supplementary centrifugation of plasma before RNA extraction eliminated the contamination and the false viraemia. Plasma isolated from standard EDTA-containing blood collection tubes may contain traces of HIV DNA leading to false viral load results above the clinical cutoff. Supplementary centrifugation of plasma before viral load analysis may eliminate the occurrence of this spurious low-level viraemia.

  15. Plasma heating for containerless and microgravity materials processing

    NASA Technical Reports Server (NTRS)

    Leung, Emily W. (Inventor); Man, Kin F. (Inventor)

    1994-01-01

    A method for plasma heating of levitated samples to be used in containerless microgravity processing is disclosed. A sample is levitated by electrostatic, electromagnetic, aerodynamic, or acoustic systems, as is appropriate for the physical properties of the particular sample. The sample is heated by a plasma torch at atmospheric pressure. A ground plate is provided to help direct the plasma towards the sample. In addition, Helmholtz coils are provided to produce a magnetic field that can be used to spiral the plasma around the sample. The plasma heating system is oriented such that it does not interfere with the levitation system.

  16. Determination of Rare Earth Elements in Geological Samples Using Laser-Induced Breakdown Spectroscopy (LIBS).

    PubMed

    Bhatt, Chet R; Jain, Jinesh C; Goueguel, Christian L; McIntyre, Dustin L; Singh, Jagdish P

    2018-01-01

    Laser-induced breakdown spectroscopy (LIBS) was used to detect rare earth elements (REEs) in natural geological samples. Low and high intensity emission lines of Ce, La, Nd, Y, Pr, Sm, Eu, Gd, and Dy were identified in the spectra recorded from the samples to claim the presence of these REEs. Multivariate analysis was executed by developing partial least squares regression (PLS-R) models for the quantification of Ce, La, and Nd. Analysis of unknown samples indicated that the prediction results of these samples were found comparable to those obtained by inductively coupled plasma mass spectrometry analysis. Data support that LIBS has potential to quantify REEs in geological minerals/ores.

  17. Inorganic trace analysis by mass spectrometry

    NASA Astrophysics Data System (ADS)

    Becker, Johanna Sabine; Dietze, Hans-Joachim

    1998-10-01

    Mass spectrometric methods for the trace analysis of inorganic materials with their ability to provide a very sensitive multielemental analysis have been established for the determination of trace and ultratrace elements in high-purity materials (metals, semiconductors and insulators), in different technical samples (e.g. alloys, pure chemicals, ceramics, thin films, ion-implanted semiconductors), in environmental samples (waters, soils, biological and medical materials) and geological samples. Whereas such techniques as spark source mass spectrometry (SSMS), laser ionization mass spectrometry (LIMS), laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS), glow discharge mass spectrometry (GDMS), secondary ion mass spectrometry (SIMS) and inductively coupled plasma mass spectrometry (ICP-MS) have multielemental capability, other methods such as thermal ionization mass spectrometry (TIMS), accelerator mass spectrometry (AMS) and resonance ionization mass spectrometry (RIMS) have been used for sensitive mono- or oligoelemental ultratrace analysis (and precise determination of isotopic ratios) in solid samples. The limits of detection for chemical elements using these mass spectrometric techniques are in the low ng g -1 concentration range. The quantification of the analytical results of mass spectrometric methods is sometimes difficult due to a lack of matrix-fitted multielement standard reference materials (SRMs) for many solid samples. Therefore, owing to the simple quantification procedure of the aqueous solution, inductively coupled plasma mass spectrometry (ICP-MS) is being increasingly used for the characterization of solid samples after sample dissolution. ICP-MS is often combined with special sample introduction equipment (e.g. flow injection, hydride generation, high performance liquid chromatography (HPLC) or electrothermal vaporization) or an off-line matrix separation and enrichment of trace impurities (especially for characterization of high-purity materials and environmental samples) is used in order to improve the detection limits of trace elements. Furthermore, the determination of chemical elements in the trace and ultratrace concentration range is often difficult and can be disturbed through mass interferences of analyte ions by molecular ions at the same nominal mass. By applying double-focusing sector field mass spectrometry at the required mass resolution—by the mass spectrometric separation of molecular ions from the analyte ions—it is often possible to overcome these interference problems. Commercial instrumental equipment, the capability (detection limits, accuracy, precision) and the analytical application fields of mass spectrometric methods for the determination of trace and ultratrace elements and for surface analysis are discussed.

  18. Fast Determination of Toxic Arsenic Species in Food Samples Using Narrow-bore High-Performance Liquid-Chromatography Inductively Coupled Plasma Mass Spectrometry.

    PubMed

    Terol, Amanda; Marcinkowska, Monika; Ardini, Francisco; Grotti, Marco

    2016-01-01

    A new method for the speciation analysis of arsenic in food using narrow-bore high-performance liquid-chromatography inductively coupled plasma mass spectrometry (HPLC-ICP-MS) has been developed. Fast separation of arsenite, arsenate, monomethylarsonic acid and dimethylarsinic acid was carried out in 7 min using an anion-exchange narrow-bore Nucleosil 100 SB column and 12 mM ammonium dihydrogen phosphate of pH 5.2 as the mobile phase, at a flow rate of 0.3 mL min(-1). A PFA-ST micronebulizer jointed to a cyclonic spray chamber was used for HPLC-ICP-MS coupling. Compared with standard-bore HPLC-ICP-MS, the new method has provided higher sensitivity, reduced mobile-phase consumption, a lower matrix plasma load and a shorter analysis time. The achieved instrumental limits of detection were in the 0.3 - 0.4 ng As mL(-1) range, and the precision was better than 3%. The arsenic compounds were efficiently (>80%) extracted from various food samples using a 1:5 methanol/water solution, with additional ultrasonic treatment for rice products. The applicability of this method was demonstrated by the analysis of several samples, such as seafood (fish, mussels, shrimps, edible algae) and rice-based products (Jasmine and Arborio rice, spaghetti, flour, crackers), including three certified reference materials.

  19. Alpha-spectrometry and fractal analysis of surface micro-images for characterisation of porous materials used in manufacture of targets for laser plasma experiments

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Aushev, A A; Barinov, S P; Vasin, M G

    2015-06-30

    We present the results of employing the alpha-spectrometry method to determine the characteristics of porous materials used in targets for laser plasma experiments. It is shown that the energy spectrum of alpha-particles, after their passage through porous samples, allows one to determine the distribution of their path length in the foam skeleton. We describe the procedure of deriving such a distribution, excluding both the distribution broadening due to statistical nature of the alpha-particle interaction with an atomic structure (straggling) and hardware effects. The fractal analysis of micro-images is applied to the same porous surface samples that have been studied bymore » alpha-spectrometry. The fractal dimension and size distribution of the number of the foam skeleton grains are obtained. Using the data obtained, a distribution of the total foam skeleton thickness along a chosen direction is constructed. It roughly coincides with the path length distribution of alpha-particles within a range of larger path lengths. It is concluded that the combined use of the alpha-spectrometry method and fractal analysis of images will make it possible to determine the size distribution of foam skeleton grains (or pores). The results can be used as initial data in theoretical studies on propagation of the laser and X-ray radiation in specific porous samples. (laser plasma)« less

  20. Survey of Florida green turtles for exposure to a disease-associated herpesvirus.

    PubMed

    Coberley, S S; Herbst, L H; Ehrhart, L M; Bagley, D A; Hirama, S; Jacobson, E R; Klein, P A

    2001-12-05

    A recently developed enzyme-linked immunosorbent assay (ELISA) was used to assess exposure of Florida wild green turtles Chelonia mydas to LETV, the herpesvirus associated with lung-eye-trachea disease (LETD). Plasma samples from 329 wild juvenile green turtles netted in the Indian River lagoon, along the Sebastian reef, or in the Trident basin (Indian River and Brevard Counties, Florida) were tested by ELISA for the presence of antibodies to LETV. Plasma samples from 180 wild juvenile green turtles were tested from these study sites to compare the prevalence of anti-LETV antibodies. While some plasma samples from each site contained anti-LETV antibodies (confirmed by Western blot analysis), plasma samples collected from the Indian River lagoon had statistically higher optical density values measured in the ELISA. No statistical differences were observed when these same plasma samples were analyzed for changes in the level of anti-LETV antibodies over 3 years (1997, 1998, and 1999). To explore the relationship between anti-LETV antibodies and fibropapillomatosis (FP), plasma from 133 green turtles scored for fibropapilloma tumor severity were tested by ELISA. There was no correlation between tumor severity and the presence of antibodies against LETV. Additional plasma samples collected from 16 tagged green turtles captured and sampled more than once (recaptures) were also tested to monitor antibody levels to LETV relative to the FP status of individual turtles over time. Again there was no clear relationship between FP tumor status and the presence of antibodies to LETV. Finally, ELISA tests on plasma from 13 nesting female turtles (9 green and 4 loggerhead) revealed high levels of anti-LETV antibodies in 11 individuals, including 2 loggerhead turtles. These results provide strong evidence that wild Florida green turtle populations at these 3 study sites are exposed to LETV or a closely related virus and that loggerhead turtles may be exposed as well. Based on a cutoff optical density value of 0.310, 71 out of the 329 wild Florida green turtles tested were seropositive for LETV antibodies (seroprevalence = 21.6%). In addition, no relationship between FP tumor severity or status and the presence of anti-LETV antibodies was found, further supporting the hypothesis that LETV and the FP-associated herpesvirus (FPHV) are separate infections of marine turtles.

  1. Absolute Quantification of Middle- to High-Abundant Plasma Proteins via Targeted Proteomics.

    PubMed

    Dittrich, Julia; Ceglarek, Uta

    2017-01-01

    The increasing number of peptide and protein biomarker candidates requires expeditious and reliable quantification strategies. The utilization of liquid chromatography coupled to quadrupole tandem mass spectrometry (LC-MS/MS) for the absolute quantitation of plasma proteins and peptides facilitates the multiplexed verification of tens to hundreds of biomarkers from smallest sample quantities. Targeted proteomics assays derived from bottom-up proteomics principles rely on the identification and analysis of proteotypic peptides formed in an enzymatic digestion of the target protein. This protocol proposes a procedure for the establishment of a targeted absolute quantitation method for middle- to high-abundant plasma proteins waiving depletion or enrichment steps. Essential topics as proteotypic peptide identification and LC-MS/MS method development as well as sample preparation and calibration strategies are described in detail.

  2. Simultaneous determination of trimethoprim and sulfamethoxazole in dried plasma and urine spots.

    PubMed

    Gonzalez, Daniel; Melloni, Chiara; Poindexter, Brenda B; Yogev, Ram; Atz, Andrew M; Sullivan, Janice E; Mendley, Susan R; Delmore, Paula; Delinsky, Amy; Zimmerman, Kanecia; Lewandowski, Andrew; Harper, Barrie; Lewis, Kenneth C; Benjamin, Daniel K; Cohen-Wolkowiez, Michael

    2015-01-01

    Trimethoprim-sulfamethoxazole (TMP-SMX) is an antimicrobial drug combination commonly prescribed in children and adults. The study objectives were to validate and apply an HPLC-MS/MS method to quantify TMP-SMX in dried plasma spots (DPS) and dried urine spots (DUS), and perform a comparability analysis with liquid matrices. For TMP the validated range was 100-50,000 ng/ml for DPS and 500-250,000 ng/ml for DUS; for SMX, the validated range was 1000-500,000 ng/ml for both DPS and DUS. Good agreement was noted between DPS/DUS and liquid plasma and urine samples for TMP, while only modest agreement was observed for SMX in both matrices. A precise, accurate and reproducible method was developed to quantify TMP-SMX in DPS and DUS samples.

  3. Progress on Pre-Stage Magnetic Coil to Enhance Helicon Mode Excitation and Data Acquisition Software on the Helicon Plasma Experiment (HPX)

    NASA Astrophysics Data System (ADS)

    Sherman, Justin; Azzari, Phillip; Crilly, P. B.; Duke-Tinson, Omar; James, Royce W.; Karama, Jackson; Page, E. J.; Schlank, Carter; Zuniga, Jonathan

    2014-10-01

    CGAPL is conducting small investigations in plasma physics and magneto-hydrodynamics buoy positioning. For data management, we are developing capability to analyze/digitize data with a National Instruments Data Acquisition board, 2 MS/s sampling rate (long time scale), and an Express Octopus card, 125 MS/s sampling rate (short scale). Sampling at 12 bits precision, we use LabVIEW as a programing language; GUIs will control variables in 1 or more concurrent runs and monitor of diagnostics. HPX utilizes high density (1013 cm3 up), low pressure (.01 T) Ar gas (fill pressure: on 104 mTorr order). Helicon/W Mode plasmas become a diagnostics test-bed for other investigations and a tool for future spacecraft propulsion devices. Plasmas created by directing energy into gas-filled Pyrex tube; power supply and matching box, up to 250 W power in 20-100 MHz frequencies, provide energy to ignite. Uniform magnetic field needed to reach the W-Mode. We employ an electromagnet to B-field while an acceleration coil positions plasma in vacuum chamber, facilitating analysis. Initial field requirements and accuracy calibration have been completed. Progress on development and implementation of probes and DAQ/GUI system will be reported. Supported by U.S. DEPS Grant [HEL-JTO] PRWJFY13.

  4. Association between the miRNA signatures in plasma and bronchoalveolar fluid in respiratory pathologies.

    PubMed

    Molina-Pinelo, Sonia; Suárez, Rocío; Pastor, María Dolores; Nogal, Ana; Márquez-Martín, Eduardo; Martín-Juan, José; Carnero, Amancio; Paz-Ares, Luis

    2012-01-01

    The identification of new less invasive biomarkers is necessary to improve the detection and prognostic outcome of respiratory pathological processes. The measurement of miRNA expression through less invasive techniques such as plasma and serum have been suggested to analysis of several lung malignancies including lung cancer. These studies are assuming a common deregulated miRNA expression both in blood and lung tissue. The present study aimed to obtain miRNA representative signatures both in plasma and bronchoalveolar cell fraction that could serve as biomarker in respiratory diseases. Ten patients were evaluated to assess the expression levels of 381 miRNAs. We found that around 50% miRNAs were no detected in both plasma and bronchoalveolar cell fraction and only 20% of miRNAs showed similar expression in both samples. These results show a lack of association of miRNA signatures between plasma and bronchoalveolar cytology in the same patient. The profiles are not comparable; however, there is a similarity in the relative expression in a very small subset of miRNAs (miR-17, miR-19b, miR-195 and miR-20b) between both biological samples in all patients. This finding supports that the miRNAs profiles obtained from different biological samples have to be carefully validated to link with respiratory diseases.

  5. Method of high-precision microsampled blood and plasma mass densitometry

    NASA Technical Reports Server (NTRS)

    Hinghofer-Szalkay, H.

    1986-01-01

    The reliability of the mechanical oscillator technique for blood and plasma density measurements on samples of volumes less than 0.1 ml is examined, and a precision of 0.001 g/l is found if plasma-isodensic heparin solution and siliconized densitometers are employed. Sources of measurement errors in the density determinations include storage of plasma samples, inhomogeneity of blood samples, and density reading before adequate temperature equilibration. In tests of plasma sample storage, the best reproducibility was obtained with samples kept at 4 C. Linear correlations were found between plasma density and plasma protein concentration, blood density and blood hemoglobin concentration, and erythrocyte density and MCHC.

  6. Simultaneous determination of acetaminophen and dihydrocodeine in human plasma by UPLC-MS/MS: Its pharmacokinetic application.

    PubMed

    Qiu, Xiangjun; Lou, Dan; Su, Ding; Liu, Zebin; Gao, Pengtao; Zhang, Nan-sheng

    2015-06-15

    An ultra performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) method was developed and validated to determine acetaminophen (AAP) and dihydrocodeine (DHC) in human plasma simultaneously. Plasma samples were prepared using protein precipitation with acetonitrile, the two analytes and the internal standard midazolam were separated on an Acquity UPLC BEH C18 column and mass spectrometric analysis was performed using a QTrap5500 mass spectrometer coupled with an electro-spray ionization (ESI) source in the positive ion mode. The MRM transitions of m/z 151.2→110.0 and m/z 302.3→199.2 were used to quantify for AAP and DHC, respectively. The linearity of this method was found to be within the concentration range of 50-10000ng/mL for AAP, and 1-100ng/mL for DHC in human plasma, respectively. The lower limit of quantification (LLOQ) was 50ng/mL and 1ng/mL for AAP and DHC in human plasma, respectively. The relative standard deviations (RSD) of intra and inter precision were less than 10% for both AAP and DHC. The analysis time of per sample was 1.0min. The developed and validated method was successfully applied to a pharmacokinetic study of AAP (500mg) with DHC (20mg) capsule in Chinese healthy volunteers (N=20). Copyright © 2015 Elsevier B.V. All rights reserved.

  7. Plasma and white adipose tissue lipid composition in marmots.

    PubMed

    Florant, G L; Nuttle, L C; Mullinex, D E; Rintoul, D A

    1990-05-01

    White adipose tissue biopsies and plasma samples were obtained from hibernating yellow-bellied marmots (Marmota flaviventris) maintained in the laboratory. In addition, biopsies and plasma samples were obtained from normothermic animals in the field and laboratory. Measurement of plasma free fatty acid (FA) levels indicated that winter laboratory animals exhibited increased lipolysis. Additionally, analysis of white adipose tissue triacylglycerol revealed that the FA composition of the storage fat in animals maintained on the standard laboratory diet is remarkably simple and uniform between different adipose depots in the same animal. Three FAs (palmitic, oleic, and linoleic acids) made up greater than 95% of the total. Triene (alpha-linolenate) was found in newly captured animals, but the percentage of this FA decreased rapidly when the animals were maintained on the standard laboratory diet. Throughout the hibernation season (October to April), white adipose tissue-saturated FA percentage decreased, monoene percentage remained constant, and diene percentage increased. Analysis of plasma FA composition suggested that these animals tended to metabolize saturated FAs from stored lipid during hibernation and that dienes were mobilized briefly after the last arousal from hibernation in spring. From these observations, we hypothesize that marmots preferentially metabolize saturated fats during the hibernation period and that essential FAs of the omega 6 series tend to be metabolized more slowly than other FAs. These characteristics suggest that marmots are a valuable animal model in which to study lipid metabolism.

  8. Determination of low concentrations of iron, arsenic, selenium, cadmium, and other trace elements in natural samples using an octopole collision/reaction cell equipped quadrupole-inductively coupled plasma mass spectrometer.

    PubMed

    Dial, Angela R; Misra, Sambuddha; Landing, William M

    2015-04-30

    Accurate determination of trace metals has many applications in environmental and life sciences, such as constraining the cycling of essential micronutrients in biological production and employing trace metals as tracers for anthropogenic pollution. Analysis of elements such as Fe, As, Se, and Cd is challenged by the formation of polyatomic mass spectrometric interferences, which are overcome in this study. We utilized an Octopole Collision/Reaction Cell (CRC)-equipped Quadrupole-Inductively Coupled Plasma Mass Spectrometer for the rapid analysis of small volume samples (~250 μL) in a variety of matrices containing HNO3 and/or HCl. Efficient elimination of polyatomic interferences was demonstrated by the use of the CRC in Reaction Mode (RM; H2 gas) and in Collision-Reaction Mode (CRM; H2 and He gas), in addition to hot plasma (RF power 1500 W) and cool plasma (600 W) conditions. It was found that cool plasma conditions with RM achieved the greatest signal sensitivity while maintaining low detection limits (i.e. (56) Fe in 0.44 M HNO3 has a sensitivity of 160,000 counts per second (cps)-per-1 µg L(-1) and a limit of detection (LoD) of 0.86 ng L(-1) ). The average external precision was ≤ ~10% for minor (≤10 µg L(-1) ) elements measured in a 1:100 dilution of NIST 1643e and for iron in rainwater samples under all instrumental operating conditions. An improved method has been demonstrated for the rapid multi-element analysis of trace metals that are challenged by polyatomic mass spectrometric interferences, with a focus on (56) Fe, (75) As, (78) Se and (111) Cd. This method can contribute to aqueous environmental geochemistry and chemical oceanography, as well as other fields such as forensic chemistry, agriculture, food chemistry, and pharmaceutical sciences. Copyright © 2015 John Wiley & Sons, Ltd.

  9. Elemental analysis of urinary calculi by laser induced plasma spectroscopy.

    PubMed

    Fang, Xiao; Ahmad, S Rafi; Mayo, Mike; Iqbal, Syed

    2005-12-01

    Laser induced plasma spectroscopy (LIPS) has been applied to analyse and identify elemental constituents of urinary calculi. Measurements on seven different urinary stone samples were conducted and the concentrations of some key elemental species were estimated. The elements detected with the present system were: Calcium, Magnesium, Sodium, Samarium, Potassium and Lead. Absolute concentrations of the species were derived from pre-calibration of the system for each element. Their concentrations were found to be widely different in different samples. It was observed that the samples containing a significant amount of lead have large proportion of calcium. It has been established that LIPS would allow real time clinic measurements of elemental contents and the concentrations in the biomaterials without sample preparation. The technique has the potential for routine clinic applications in urological disorder diagnosis.

  10. Direct trace-elemental analysis of urine samples by laser ablation-inductively coupled plasma mass spectrometry after sample deposition on clinical filter papers.

    PubMed

    Aramendía, Maite; Rello, Luis; Vanhaecke, Frank; Resano, Martín

    2012-10-16

    Collection of biological fluids on clinical filter papers shows important advantages from a logistic point of view, although analysis of these specimens is far from straightforward. Concerning urine analysis, and particularly when direct trace elemental analysis by laser ablation-inductively coupled plasma mass spectrometry (LA-ICPMS) is aimed at, several problems arise, such as lack of sensitivity or different distribution of the analytes on the filter paper, rendering obtaining reliable quantitative results quite difficult. In this paper, a novel approach for urine collection is proposed, which circumvents many of these problems. This methodology consists on the use of precut filter paper discs where large amounts of sample can be retained upon a single deposition. This provides higher amounts of the target analytes and, thus, sufficient sensitivity, and allows addition of an adequate internal standard at the clinical lab prior to analysis, therefore making it suitable for a strategy based on unsupervised sample collection and ulterior analysis at referral centers. On the basis of this sampling methodology, an analytical method was developed for the direct determination of several elements in urine (Be, Bi, Cd, Co, Cu, Ni, Sb, Sn, Tl, Pb, and V) at the low μg L(-1) level by means of LA-ICPMS. The method developed provides good results in terms of accuracy and LODs (≤1 μg L(-1) for most of the analytes tested), with a precision in the range of 15%, fit-for-purpose for clinical control analysis.

  11. Description and Operation of the Mark 1B Plasma Focus Radiation Facility,

    DTIC Science & Technology

    plasma focus facility (Mk 1B) at The Aerospace Corporation produces x-ray fluences that are applicable to most radiation testing problems (e.g., integrated circuits or transistors). Although the facility has only one beryllium window for exposing 1.6-cm-dia samples to doses of 25 to 45 krad (Si) per shot, three more windows could be added and the additional samples exposed simultaneously. The facility is experiencing switch problems and is presently averaging 50 shots per week--15 shots per day for 3 or 4 days. The results of a comprehensive switch analysis should

  12. Analysis of Rare Earth Elements in Geologic Samples using Inductively Coupled Plasma Mass Spectrometry; US DOE Topical Report - DOE/NETL-2016/1794

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bank, Tracy L.; Roth, Elliot A.; Tinker, Phillip

    2016-04-17

    Inductively Coupled Plasma Mass Spectrometry (ICP-MS) is used to measure the concentrations of rare earth elements (REE) in certified standard reference materials including shale and coal. The instrument used in this study is a Perkin Elmer Nexion 300D ICP-MS. The goal of the study is to identify sample preparation and operating conditions that optimized recovery of each element of concern. Additionally, the precision and accuracy of the technique are summarized and the drawbacks and limitations of the method are outlined.

  13. Analysis of thyroid hormones in biological samples using stable isotope dilution liquid chromatography-tandem mass spectrometry

    EPA Science Inventory

    This poster presentation will describe analytical chemistry methods for measuring thyroid hormones and related precursors and metabolites in very small tissue or plasma samples. These methods are amenable to measure thyroid hormones in amphibian tadpoles or small mammals used as ...

  14. Evaluation of the Aptima HBV Quant assay vs. the COBAS TaqMan HBV test using the high pure system for the quantitation of HBV DNA in plasma and serum samples.

    PubMed

    Schalasta, Gunnar; Börner, Anna; Speicher, Andrea; Enders, Martin

    2018-03-28

    Proper management of patients with chronic hepatitis B virus (HBV) infection requires monitoring of plasma or serum HBV DNA levels using a highly sensitive nucleic acid amplification test. Because commercially available assays differ in performance, we compared herein the performance of the Hologic Aptima HBV Quant assay (Aptima) to that of the Roche Cobas TaqMan HBV test for use with the high pure system (HPS/CTM). Assay performance was assessed using HBV reference panels as well as plasma and serum samples from chronically HBV-infected patients. Method correlation, analytical sensitivity, precision/reproducibility, linearity, bias and influence of genotype were evaluated. Data analysis was performed using linear regression, Deming correlation analysis and Bland-Altman analysis. Agreement between the assays for the two reference panels was good, with a difference in assay values vs. target <0.5 log. Qualitative assay results for 159 clinical samples showed good concordance (88.1%; κ=0.75; 95% confidence interval: 0.651-0.845). For the 106 samples quantitated by both assays, viral load results were highly correlated (R=0.92) and differed on average by 0.09 log, with 95.3% of the samples being within the 95% limit of agreement of the assays. Linearity for viral loads 1-7 log was excellent for both assays (R2>0.98). The two assays had similar bias and precision across the different genotypes tested at low viral loads (25-1000 IU/mL). Aptima has a performance comparable with that of HPS/CTM, making it suitable for use for HBV infection monitoring. Aptima runs on a fully automated platform (the Panther system) and therefore offers a significantly improved workflow compared with HPS/CTM.

  15. Quantitative analysis of deuterium in zircaloy using double-pulse laser-induced breakdown spectrometry (LIBS) and helium gas plasma without a sample chamber.

    PubMed

    Suyanto, H; Lie, Z S; Niki, H; Kagawa, K; Fukumoto, K; Rinda, Hedwig; Abdulmadjid, S N; Marpaung, A M; Pardede, M; Suliyanti, M M; Hidayah, A N; Jobiliong, E; Lie, T J; Tjia, M O; Kurniawan, K H

    2012-03-06

    A crucial safety measure to be strictly observed in the operation of heavy-water nuclear power plants is the mandatory regular inspection of the concentration of deuterium penetrated into the zircaloy fuel vessels. The existing standard method requires a tedious, destructive, and costly sample preparation process involving the removal of the remaining fuel in the vessel and melting away part of the zircaloy pipe. An alternative method of orthogonal dual-pulse laser-induced breakdown spectrometry (LIBS) is proposed by employing flowing atmospheric helium gas without the use of a sample chamber. The special setup of ps and ns laser systems, operated for the separate ablation of the sample target and the generation of helium gas plasma, respectively, with properly controlled relative timing, has succeeded in producing the desired sharp D I 656.10 nm emission line with effective suppression of the interfering H I 656.28 nm emission by operating the ps ablation laser at very low output energy of 26 mJ and 1 μs ahead of the helium plasma generation. Under this optimal experimental condition, a linear calibration line is attained with practically zero intercept and a 20 μg/g detection limit for D analysis of zircaloy sample while creating a crater only 10 μm in diameter. Therefore, this method promises its potential application for the practical, in situ, and virtually nondestructive quantitative microarea analysis of D, thereby supporting the more-efficient operation and maintenance of heavy-water nuclear power plants. Furthermore, it will also meet the anticipated needs of future nuclear fusion power plants, as well as other important fields of application in the foreseeable future.

  16. Tandem Laser Induced Breakdown Spectroscopy (LIBS), Laser Ablation Inductively Coupled Plasma Mass Spectroscopy (LA-ICP-MS) and/or Laser Ablation Inductively Coupled Plasma Optical Emission Spectroscopy (LA-ICP-OES) for the analysis of samples of geological interest

    NASA Astrophysics Data System (ADS)

    Oropeza, D.

    2016-12-01

    A highly innovative laser ablation sampling instrument (J200 Tandem LA - LIBS) that combines the capabilities and analytical benefits of LIBS, LA-ICP-MS and LA-ICP-OES was used for micrometer-scale, spatially-resolved, elemental analysis of a wide variety of samples of geological interest. Data collected using ablation systems consisted of nanosecond (Nd:YAG operated 266nm) and femtosecond lasers (1030 and 343nm). An ICCD LIBS detector and Quadrupole based mass spectrometer were selected for LIBS and ICP-MS detection, respectively. This tandem instrument allows simultaneous determination of major and minor elements (for example, Si, Ca, Na, and Al, and trace elements such as Li, Ce, Cr, Sr, Y, Zn, Zr among others). The research also focused on elemental mapping and calibration strategies, specifically the use of emission and mass spectra for multivariate data analysis. Partial Least Square Regression (PLSR) is shown to minimize and compensate for matrix effects in the emission and mass spectra improving quantitative analysis by LIBS and LA-ICP-MS, respectively. The study provides a benchmark to evaluate analytical results for more complex geological sample matrices.

  17. Novel enzyme-linked immunosorbent assay for determination of fluvastatin in plasma at picogram level.

    PubMed

    Darwish, Ibrahim A; Al-Obaid, Abdul-Rahman M; Al-Malaq, Hamoud A

    2009-11-15

    For the first time, an enzyme-linked immunosorbent assay (ELISA) has been developed and validated for the determination of fluvastatin (FLV) in plasma samples at picogram level. The assay employed a polyclonal antibody that specifically recognizes FLV with high affinity, and FLV conjugate of bovine serum albumin (FLV-BSA) immobilized onto microplate wells as a solid-phase. The assay involved a competitive binding reaction between FLV, in plasma sample, and the immobilized FLV-BSA for the binding sites on a limited amount of the anti-FLV antibody. The bound anti-FLV antibody was quantified with horseradish peroxidase-labeled second anti-rabbit IgG antibody (HRP-IgG) and 3,3',5,5'-tetramethylbenzidine (TMB) as a substrate for the peroxidase enzyme. The concentration of FLV in the sample was quantified by its ability to inhibit the binding of the anti-FLV antibody to the immobilized FLV-BSA and subsequently the color intensity in the assay wells. The conditions for the proposed ELISA were investigated and the optimum conditions were employed in the determination of FLV in plasma samples. The assay limit of detection was 10 pg mL(-1) and the effective working range at relative standard deviations (RSD) of

  18. Liquid Biopsy Analysis of FGFR3 and PIK3CA Hotspot Mutations for Disease Surveillance in Bladder Cancer.

    PubMed

    Christensen, Emil; Birkenkamp-Demtröder, Karin; Nordentoft, Iver; Høyer, Søren; van der Keur, Kirstin; van Kessel, Kim; Zwarthoff, Ellen; Agerbæk, Mads; Ørntoft, Torben Falck; Jensen, Jørgen Bjerggaard; Dyrskjøt, Lars

    2017-06-01

    Disease surveillance in patients with bladder cancer is important for early diagnosis of progression and metastasis and for optimised treatment. To develop urine and plasma assays for disease surveillance for patients with FGFR3 and PIK3CA tumour mutations. Droplet digital polymerase chain reaction (ddPCR) assays were developed and tumour DNA from two patient cohorts was screened for FGFR3 and PIK3CA hotspot mutations. One cohort included 363 patients with non-muscle-invasive bladder cancer (NMIBC). The other cohort included 468 patients with bladder cancer undergoing radical cystectomy (Cx). Urine supernatants (NMIBC n=216, Cx n=27) and plasma samples (NMIBC n=39, Cx n=27) from patients harbouring mutations were subsequently screened using ddPCR assays. Progression-free survival, recurrence-free survival, and overall survival were measured. Fisher's exact test, the Wilcoxon rank-sum test and Cox regression analysis were applied. In total, 36% of the NMIBC patients (129/363) and 11% of the Cx patients (44/403) harboured at least one FGFR3 or PIK3CA mutation. Screening of DNA from serial urine supernatants from the NMIBC cohort revealed that high levels of tumour DNA (tDNA) were associated with later disease progression in NMIBC (p=0.003). Furthermore, high levels of tDNA in plasma samples were associated with recurrence in the Cx cohort (p=0.016). A positive correlation between tDNA levels in urine and plasma was observed (correlation coefficient 0.6). The retrospective study design and low volumes of plasma available for analysis were limitations of the study. Increased levels of FGFR3 and PIK3CA mutated DNA in urine and plasma are indicative of later progression and metastasis in bladder cancer. Urine and plasma from patients with bladder cancer may be monitored for diagnosis of progression and metastasis using mutation assays. Copyright © 2016 European Association of Urology. Published by Elsevier B.V. All rights reserved.

  19. Plasma-enhanced synthesis of green flame retardant cellulosic materials

    NASA Astrophysics Data System (ADS)

    Totolin, Vladimir

    The natural fiber-containing fabrics and composites are more environmentally friendly, and are used in transportation (automobiles, aerospace), military applications, construction industries (ceiling paneling, partition boards), consumer products, etc. Therefore, the flammability characteristics of the composites based on polymers and natural fibers play an important role. This dissertation presents the development of plasma assisted - green flame retardant coatings for cellulosic substrates. The overall objective of this work was to generate durable flame retardant treatment on cellulosic materials. In the first approach sodium silicate layers were pre-deposited onto clean cotton substrates and cross linked using low pressure, non-equilibrium oxygen plasma. A statistical design of experiments was used to optimize the plasma parameters. The modified cotton samples were tested for flammability using an automatic 45° angle flammability test chamber. Aging tests were conducted to evaluate the coating resistance during the accelerated laundry technique. The samples revealed a high flame retardant behavior and good thermal stability proved by thermo-gravimetric analysis. In the second approach flame retardant cellulosic materials have been produced using a silicon dioxide (SiO2) network coating. SiO 2 network armor was prepared through hydrolysis and condensation of the precursor tetraethyl orthosilicate (TEOS), prior coating the substrates, and was cross linked on the surface of the substrates using atmospheric pressure plasma (APP) technique. Due to protection effects of the SiO2 network armor, the cellulosic based fibers exhibit enhanced thermal properties and improved flame retardancy. In the third approach, the TEOS/APP treatments were extended to linen fabrics. The thermal analysis showed a higher char content and a strong endothermic process of the treated samples compared with control ones, indicating a good thermal stability. Also, the surface analysis proved the existence of the silica-based coatings on all treated cellulosic substrates after intense ultrasound washes. The results obtained in this work allow us to conclude that silica-based coatings used in conjunction with plasma processes have high potential to obtain green flame retardant cellulosic materials with potential applications in the development of upholstered furniture, clothing and military applications.

  20. Cadmium, copper, lead, and zinc determination in precipitation: A comparison of inductively coupled plasma atomic emission spectrometry and graphite furnace atomization atomic absorption spectrometry

    USGS Publications Warehouse

    Reddy, M.M.; Benefiel, M.A.; Claassen, H.C.

    1987-01-01

    Selected trace element analysis for cadmium, copper, lead, and zinc in precipitation samples by inductively coupled plasma atomic emission Spectrometry (ICP) and by atomic absorption spectrometry with graphite furnace atomization (AAGF) have been evaluated. This task was conducted in conjunction with a longterm study of precipitation chemistry at high altitude sites located in remote areas of the southwestern United States. Coefficients of variation and recovery values were determined for a standard reference water sample for all metals examined for both techniques. At concentration levels less than 10 micrograms per liter AAGF analyses exhibited better precision and accuracy than ICP. Both methods appear to offer the potential for cost-effective analysis of trace metal ions in precipitation. ?? 1987 Springer-Verlag.

  1. Reduction of Net Erosion of High-Z Divertor Surface by Local Redeposition in DIII-D

    NASA Astrophysics Data System (ADS)

    Stangeby, P. C.

    2012-10-01

    Utilizing the unique capability to expose material samples to well characterized diverted plasmas, recent DIII-D measurements have confirmed theoretical expectations of the relative net and gross erosion rates of molybdenum in the divertor region. Knowledge of these erosion rates is important for predicting first wall lifetime in future fusion devices. Theory suggests that the net erosion rate will be much less than gross erosion due to prompt local deposition of eroded ions by gyro-orbit motion, the strong E-field toward the target and friction with the fast plasma flow toward the target. However, experimental evidence to date has been contradictory. The results here, which are the most definitive to date, are consistent with the basic theoretical predictions. The net and gross erosion rates were measured utilizing 1-cm and 1-mm diameter Mo samples that are mounted on the DIII-D Divertor Material Evaluation System (DiMES) system and simultaneously exposed near the attached outer strike point of an L-mode plasma for 4 s. Due to the spatial extent of the re-deposition, the larger sample gives the net erosion while the smaller sample is indicative of the gross erosion. Post-mortem ion beam analysis (RBS) of the larger sample, indicates a 2.9 nm film thickness reduction (or 0.72 nm/s net erosion rate). Similar analysis of the smaller sample yields a 1.3 nm/s gross erosion rate, consistent with spectroscopic measurements of Mo I emission. The net to gross erosion ratio of 0.56 is consistent with calculations using a modeling package including REDEP/WBS and OEDGE codes. Using as input the measured plasma density and temperature profiles from divertor Langmuir probes, these codes estimate a net to gross erosion ratio of 0.46. Details of the modeling and implications for future devices will be discussed.

  2. Analysis of nutrition-relevant trace elements in human blood and serum by means of total reflection X-ray fluorescence (TXRF) spectroscopy

    NASA Astrophysics Data System (ADS)

    Stosnach, Hagen; Mages, Margarete

    2009-04-01

    In clinical service laboratories, one of the most common analytical tasks with regard to inorganic traces is the determination of the nutrition-relevant elements Fe, Cu, Zn, and Se. Because of the high numbers of samples and the commercial character of these analyses, a time-consuming sample preparation must be avoided. In this presentation, the results of total reflection X-ray fluorescence measurements with a low-power system and different sample preparation procedures are compared with those derived from analysis with common methods like Atomic Absorption Spectroscopy (AAS) and Inductively Coupled Plasma Mass Spectroscopy (ICP-MS). The results of these investigations indicate that the optimal total reflection X-ray fluorescence analysis of the nutrition-relevant elements Fe, Cu, Zn, and Se can be performed by preparing whole blood and serum samples after dilution with ultrapure water and transferring 10 μl of internally standardized sample to an unsiliconized quartz glass sample carrier with subsequent drying in a laboratory oven. Suitable measurement time was found to be 600 s. The enhanced sample preparation by means of microwave or open digestion, in parts combined with cold plasma ashing, led to an improvement of detection limits by a factor of 2 for serum samples while for whole blood samples an improvement was only observed for samples prepared by means of microwave digestion. As the matrix elements P, S, Cl, and for whole blood Fe have a major influence on the detection limits, most probably a further enhancement of analytical quality requires the removal of the organic matrix. However, for the routine analysis of the nutrition-relevant elements, the dilution preparation was found to be sufficient.

  3. Studies of Be migration in the JET tokamak using AMS with 10Be marker

    NASA Astrophysics Data System (ADS)

    Bykov, I.; Bergsåker, H.; Possnert, G.; Zhou, Y.; Heinola, K.; Pettersson, J.; Conroy, S.; Likonen, J.; Petersson, P.; Widdowson, A.

    2016-03-01

    The JET tokamak is operated with beryllium limiter tiles in the main chamber and tungsten coated carbon fiber composite tiles and solid W tiles in the divertor. One important issue is how wall materials are migrating during plasma operation. To study beryllium redistribution in the main chamber and in the divertor, a 10Be enriched limiter tile was installed prior to plasma operations in 2011-2012. Methods to take surface samples have been developed, an abrasive method for bulk Be tiles in the main chamber, which permits reuse of the tiles, and leaching with hot HCl to remove all Be deposited at W coated surfaces in the divertor. Quantitative analysis of the total amount of Be in cm2 sized samples was made with inductively coupled plasma atomic emission spectroscopy (ICP-AES). The 10Be/9Be ratio in the samples was measured with accelerator mass spectrometry (AMS). The experimental setup and methods are described in detail, including sample preparation, measures to eliminate contributions in AMS from the 10B isobar, possible activation due to plasma generated neutrons and effects of diffusive isotope mixing. For the first time marker concentrations are measured in the divertor deposits. They are in the range 0.4-1.2% of the source concentration, with moderate poloidal variation.

  4. Measurement and analysis of x-ray absorption in Al and MgF2 plasmas heated by Z-pinch radiation.

    PubMed

    Rochau, Gregory A; Bailey, J E; Macfarlane, J J

    2005-12-01

    High-power Z pinches on Sandia National Laboratories' Z facility can be used in a variety of experiments to radiatively heat samples placed some distance away from the Z-pinch plasma. In such experiments, the heating radiation spectrum is influenced by both the Z-pinch emission and the re-emission of radiation from the high-Z surfaces that make up the Z-pinch diode. To test the understanding of the amplitude and spectral distribution of the heating radiation, thin foils containing both Al and MgF2 were heated by a 100-130 TW Z pinch. The heating of these samples was studied through the ionization distribution in each material as measured by x-ray absorption spectra. The resulting plasma conditions are inferred from a least-squares comparison between the measured spectra and calculations of the Al and Mg 1s-->2p absorption over a large range of temperatures and densities. These plasma conditions are then compared to radiation-hydrodynamics simulations of the sample dynamics and are found to agree within 1sigma to the best-fit conditions. This agreement indicates that both the driving radiation spectrum and the heating of the Al and MgF2 samples is understood within the accuracy of the spectroscopic method.

  5. The measurement of acetanilide in plasma by spectrophotometric and selected ion monitoring methods.

    PubMed

    Baty, J D; Playfer, J; Evans, D A; Lamb, J

    1977-08-01

    Plasma samples from volunteers who had received an oral dose of acetanilide have been analysed by gas chromatography mass spectrometry and ultraviolet absorption techniques. The gas chromatography mass spectrometry method involved extraction of the plasma and analysis of the acetanilide using selected ion monitoring with a deuterated internal standard. In the ultraviolet method the plasma was hydrolysed with acid to convert the acetanilide to aniline, and this compound was diazotized and coupled with N-1-naphthylethylene-diamine. The absorbance of the resulting complex was read at 550 nm. Acetanilide levels in plasma determined by the selected ion monitoring method were significantly lower than those measured by spectrophotometry. Pharmacokinetic data calculated from the results obtained using these two assays are very different and illustrate the need for an accurate and specific method of analysis. The major metabolites of acetanilide are shown not to interfere with these assays and the results suggest the possible presence of a new metabolite of acetanilide.

  6. Direct analysis of deodorants for determination of metals by inductively coupled plasma optical emission spectrometry.

    PubMed

    da Costa, Wiviane Kássia Oliveira Correia; da Silva, Caroline Santos; Figueiredo, José Fernando Dagnone; Nóbrega, Joaquim Araujo; Paim, Ana Paula Silveira

    2018-06-05

    A fast and simple dilute-and-shoot procedure for determination of Al, As, Ba, Cd, Cu, Fe, Mg, Mn, Ni, Pb, Sc, Ti, V, Zn and Zr in deodorants by inductively coupled plasma optical emission spectrometry (ICP OES) was developed. Sample preparation was carried out by diluting 1 mL of deodorant sample in 1% (v v -1 ) HNO 3 . The accuracy of the analytical procedure was evaluated using addition and recovery experiments, and recoveries ranged from 80 to 119%. The limits of detection varied from 0.001 to 0.76 mg kg -1 . Nine deodorants samples of different brands were analyzed. The maximum concentrations found (mg kg -1 ) were: Fe (1.0), Mn (0.1), Ti (1.02), V (0.33), Zn (255.2) and Zr (0.5); for Al and Mg, determined concentrations varied from 0.01 to 7.0% and from 0.005 to 1.44 mg kg -1 , respectively, showing wide variation depending on the sample type. The developed procedure was adequate for determining these analytes in routine analysis presenting high sample throughput and demonstrated the feasibility of direct analysis measurements after simple dilution step. Copyright © 2018 Elsevier B.V. All rights reserved.

  7. Multielemental analysis in small amounts of environmental reference materials with inductively coupled plasma mass spectrometry.

    PubMed

    Dombovári, J; Becker, J S; Dietze, H J

    2000-07-01

    The lowest possible sample weight for performing multielemental trace element analysis on environmental and biological samples by ICP-MS has been investigated. The certified reference materials Bovine Liver NIST SRM 1577b, Human Hair NCS DC 73347 and Oriental Tobacco Leaves CTA-OTL-1 were applied at sample weights (1, 5, 20 and 50 mg aliquots, n = 10) which were significantly lower than those recommended with most recoveries in the range of 95-110%. Samples were digested in a mixture of nitric acid, hydrogen peroxide and hydrogen fluoride by closed-vessel microwave digestion. Multielemental analysis was performed with an optimized ICP-QMS method. Aqueous standard solutions were applied for external calibration with rhodium as the internal standard element. The detection limits varied between 0.02-0.38 microg/g for Li, Na, Cr, Mn, Ni, Cu, Zn, Sr, Cd, Ba and Pb, and up to 1.92 microg/g for Mg, Al, Ca, Fe and Ni. Digested human plasma samples were spiked with multielemental solution (0.5-10 microg/L) to test the analytical method and the recoveries were 95-105% for most analytes. Our results show that in the case of homogeneous SRMs it is possible to use them in very low amounts (1-5 mg) for method development and quality control.

  8. Depleted uranium analysis in blood by inductively coupled plasma mass spectrometry

    USGS Publications Warehouse

    Todorov, T.I.; Xu, H.; Ejnik, J.W.; Mullick, F.G.; Squibb, K.; McDiarmid, M.A.; Centeno, J.A.

    2009-01-01

    In this study we report depleted uranium (DU) analysis in whole blood samples. Internal exposure to DU causes increased uranium levels as well as change in the uranium isotopic composition in blood specimen. For identification of DU exposure we used the 235U/238U ratio in blood samples, which ranges from 0.00725 for natural uranium to 0.002 for depleted uranium. Uranium quantification and isotopic composition analysis were performed by inductively coupled plasma mass spectrometry. For method validation we used eight spiked blood samples with known uranium concentrations and isotopic composition. The detection limit for quantification was determined to be 4 ng L-1 uranium in whole blood. The data reproduced within 1-5% RSD and an accuracy of 1-4%. In order to achieve a 235U/238U ratio range of 0.00698-0.00752% with 99.7% confidence limit a minimum whole blood uranium concentration of 60 ng L??1 was required. An additional 10 samples from a cohort of veterans exposed to DU in Gulf War I were analyzed with no knowledge of their medical history. The measured 235U/ 238U ratios in the blood samples were used to identify the presence or absence of DU exposure within this patient group. ?? 2009 The Royal Society of Chemistry.

  9. A micro-fluidic sub-microliter sample introduction system for direct analysis of Chinese rice wine by inductively coupled plasma mass spectrometry using external aqueous calibration

    NASA Astrophysics Data System (ADS)

    Cheng, Heyong; Liu, Jinhua; Xu, Zigang; Yin, Xuefeng

    2012-07-01

    A microfluidic sub-microliter sample introducing system was developed for direct analysis of Chinese rice wine by inductively coupled plasma mass spectrometry (ICP-MS). It consisted of a microfluidic chip integrating variable-volume sampling channels (0.1-0.8 μL), an eight-way multi-functional valve used in flow injection analysis (FIA), a syringe pump and a peristaltic pump of the Ar ICP-MS instrument. Three solutions, i.e., 15, 40 and 100 g L- 1 glucose in 20% ethanol were used to simulate Chinese rice wine of the dry type, the semidry type and the semisweet type, each. The effects of their volume introduced into ICP-MS on the plasma stability and ICP-MS intensities were studied. The experimental results showed that neither alteration of plasma stability nor carbon deposition was observed when the sampling volume of 20% ethanol containing 100 g L- 1 glucose was downscaled to 0.8 μL. Further reducing the sampling volume to 0.4 μL, no significant difference between the intensities of multi-element standard prepared in three simulated Chinese rice wine matrices and those in aqueous solution was observed. It indicated no negative effect of Chinese rice wine matrix on the ICP-MS intensities. A sampling volume of 0.4 μL was considered to be a good compromise between sensitivity and matrix effect. The flow rate of the carrier was chosen as 20 μL min- 1 for obtaining peaks with the highest peak height within the shortest time. Based on these observations, a microflow injection (μFI) method for the direct determination of cadmium and lead in Chinese rice wine by ICP-MS using an external aqueous calibration was developed. The sample throughput was 45 h- 1 with the detection limit of 19.8 and 10.4 ng L- 1 for Cd and Pb, respectively. The contents of Cd and Pb in 10 Chinese rice wine samples were measured. The results agreed well with those determined by ICP-MS with the conventional sampling system after microwave assisted digestion. The recoveries of three Chinese rice wine samples ranged between 95.5 and 102.8%. Furthermore, the determined contents of Cd and Pb in a certified reference material of red wine (GBW 10031) and a quality control test material of wine (FAPAS T07163QC) by the proposed method were in fairly good accordance with the certified/assigned values. All results verified the accuracy of our method.

  10. Surface analysis under ambient conditions using plasma-assisted desorption/ionization mass spectrometry.

    PubMed

    Ratcliffe, Lucy V; Rutten, Frank J M; Barrett, David A; Whitmore, Terry; Seymour, David; Greenwood, Claire; Aranda-Gonzalvo, Yolanda; Robinson, Steven; McCoustra, Martin

    2007-08-15

    A novel plasma-assisted desorption/ionization (PADI) method that can be coupled with atmospheric pressure sampling mass spectrometry to yield mass spectral information under ambient conditions of pressure and humidity from a range of surfaces without the requirement for sample preparation or additives is reported. PADI is carried out by generating a nonthermal plasma which interacts directly with the surface of the analyte. Desorption and ionization then occur at the surface, and ions are sampled by the mass spectrometer. The PADI technique is demonstrated and compared with desorption electrospray ionization (DESI) for the detection of active ingredients in a range of over-the-counter and prescription pharmaceutical formulations, including nonsterodial anti-inflammatory drugs (mefenamic acid, Ibugel, and ibuprofen), analgesics (paracetamol, Anadin Extra), and Beecham's "all in one" cold and flu remedy. PADI has also been successfully applied to the analysis of nicotine in tobacco and thiosulfates in garlic. PADI experiments have been performed using a prototype source interfaced with a Waters Platform LCZ single-quadrupole mass spectrometer with limited modifications and a Hiden Analytical HPR-60 molecular beam mass spectrometer (MBMS). The ability of PADI to rapidly detect active ingredients in pharmaceuticals without the need for prior sample preparation, solvents, or exposed high voltages demonstrates the potential of the technique for high-throughput screening in a pharmaceutical or forensic environment.

  11. Comparison of direct sampling and brochoalveolar lavage for determining active drug concentrations in the pulmonary epithelial lining fluid of calves injected with enrofloxacin or tilmicosin.

    PubMed

    Foster, D M; Sylvester, H J; Papich, M G

    2017-12-01

    Antibiotic distribution to interstitial fluid (ISF) and pulmonary epithelial fluid (PELF) was measured and compared to plasma drug concentrations in eight healthy calves. Enrofloxacin (Baytril ® 100) was administered at a dose of 12.5 mg/kg subcutaneously (SC), and tilmicosin (Micotil ® 300) was administered at a dose of 20 mg/kg SC. PELF, sampled by two different methods-bronchoalveolar lavage (BAL) and direct sampling (DS)-plasma, and ISF were collected from each calf and measured for tilmicosin, enrofloxacin and its metabolite ciprofloxacin by HPLC. Pharmacokinetic analysis was performed on the concentrations in each fluid, for each drug. The enrofloxacin/ciprofloxacin concentration as measured by AUC in DS samples was 137 ± 72% higher than in plasma, but in BAL samples, this value was 535 ± 403% (p < .05). The concentrations of tilmicosin in DS and BAL samples exceeded plasma drug concentrations by 567 ± 189% and 776 ± 1138%, respectively. The enrofloxacin/ciprofloxacin concentrations collected by DS were significantly different than those collected by BAL, but the tilmicosin concentrations were not significantly different between the two methods. Concentrations of enrofloxacin/ciprofloxacin exceeded the MIC values for bovine respiratory disease pathogens but tilmicosin did not reach MIC levels for these pathogens in any fluids. © 2017 John Wiley & Sons Ltd.

  12. Properties of various plasma surface treatments for low-temperature Au–Au bonding

    NASA Astrophysics Data System (ADS)

    Yamamoto, Michitaka; Higurashi, Eiji; Suga, Tadatomo; Sawada, Renshi; Itoh, Toshihiro

    2018-04-01

    Atmospheric-pressure (AP) plasma treatment using three different types of gases (an argon-hydrogen mixed gas, an argon-oxygen mixed gas, and a nitrogen gas) and low-pressure (LP) plasma treatment using an argon gas were compared for Au–Au bonding with thin films and stud bumps at low temperature (25 or 150 °C) in ambient air. The argon-hydrogen gas mixture AP plasma treatment and argon LP plasma treatment were found to distinctly increase the shear bond strength for both samples at both temperatures. From X-ray photoelectron spectroscopy (XPS) analysis, the removal of organic contaminants on Au surfaces without the formation of hydroxyl groups and gold oxide is considered effective in increasing the Au–Au bonding strength at low temperature.

  13. Trace element analysis of extraterrestrial metal samples by inductively coupled plasma mass spectrometry: the standard solutions and digesting acids.

    PubMed

    Wang, Guiqin; Wu, Yangsiqian; Lin, Yangting

    2016-02-28

    Nearly 99% of the total content of extraterrestrial metals is composed of Fe and Ni, but with greatly variable trace element contents. The accuracy obtained in the inductively coupled plasma mass spectrometry (ICP-MS) analysis of solutions of these samples can be significantly influenced by matrix contents, polyatomic ion interference, and the concentrations of external standard solutions. An ICP-MS instrument (X Series 2) was used to determine 30 standard solutions with different concentrations of trace elements, and different matrix contents. Based on these measurements, the matrix effects were determined. Three iron meteorites were dissolved separately in aqua regia and HNO3. Deviations due to variation of matrix contents in the external standard solutions were evaluated and the analysis results of the two digestion methods for iron meteorites were assessed. Our results show obvious deviations due to unmatched matrix contents in the external standard solutions. Furthermore, discrepancy in the measurement of some elements was found between the sample solutions prepared with aqua regia and HNO3, due to loss of chloride during sample preparation and/or incomplete digestion of highly siderophile elements in iron meteorites. An accurate ICP-MS analysis method for extraterrestrial metal samples has been established using external standard solutions with matched matrix contents and digesting the samples with HNO3 and aqua regia. Using the data from this work, the Mundrabilla iron meteorite previously classified as IAB-ung is reclassified as IAB-MG. Copyright © 2016 John Wiley & Sons, Ltd.

  14. Serial circulating tumour DNA analysis during multimodality treatment of locally advanced rectal cancer: a prospective biomarker study.

    PubMed

    Tie, Jeanne; Cohen, Joshua D; Wang, Yuxuan; Li, Lu; Christie, Michael; Simons, Koen; Elsaleh, Hany; Kosmider, Suzanne; Wong, Rachel; Yip, Desmond; Lee, Margaret; Tran, Ben; Rangiah, David; Burge, Matthew; Goldstein, David; Singh, Madhu; Skinner, Iain; Faragher, Ian; Croxford, Matthew; Bampton, Carolyn; Haydon, Andrew; Jones, Ian T; S Karapetis, Christos; Price, Timothy; Schaefer, Mary J; Ptak, Jeanne; Dobbyn, Lisa; Silliman, Natallie; Kinde, Isaac; Tomasetti, Cristian; Papadopoulos, Nickolas; Kinzler, Kenneth; Volgestein, Bert; Gibbs, Peter

    2018-02-02

    For patients with locally advanced rectal cancer (LARC), adjuvant chemotherapy selection following surgery remains a major clinical dilemma. Here, we investigated the ability of circulating tumour DNA (ctDNA) to improve risk stratification in patients with LARC. We enrolled patients with LARC (T3/T4 and/or N+) planned for neoadjuvant chemoradiotherapy. Plasma samples were collected pretreatment, postchemoradiotherapy and 4-10 weeks after surgery. Somatic mutations in individual patient's tumour were identified via massively parallel sequencing of 15 genes commonly mutated in colorectal cancer. We then designed personalised assays to quantify ctDNA in plasma samples. Patients received adjuvant therapy at clinician discretion, blinded to the ctDNA results. We analysed 462 serial plasma samples from 159 patients. ctDNA was detectable in 77%, 8.3% and 12% of pretreatment, postchemoradiotherapy and postsurgery plasma samples. Significantly worse recurrence-free survival was seen if ctDNA was detectable after chemoradiotherapy (HR 6.6; P<0.001) or after surgery (HR 13.0; P<0.001). The estimated 3-year recurrence-free survival was 33% for the postoperative ctDNA-positive patients and 87% for the postoperative ctDNA-negative patients. Postoperative ctDNA detection was predictive of recurrence irrespective of adjuvant chemotherapy use (chemotherapy: HR 10.0; P<0.001; without chemotherapy: HR 22.0; P<0.001). Postoperative ctDNA status remained an independent predictor of recurrence-free survival after adjusting for known clinicopathological risk factors (HR 6.0; P<0.001). Postoperative ctDNA analysis stratifies patients with LARC into subsets that are either at very high or at low risk of recurrence, independent of conventional clinicopathological risk factors. ctDNA analysis could potentially be used to guide patient selection for adjuvant chemotherapy. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  15. Recovery of Drug Delivery Nanoparticles from Human Plasma using an Electrokinetic Platform Technology

    PubMed Central

    Ibsen, Stuart; Sonnenberg, Avery; Schutt, Carolyn; Mukthavaram, Rajesh; Yeh, Yasan; Ortac, Inanc; Manouchehri, Sareh; Kesari, Santosh; Esener, Sadik

    2015-01-01

    The effect of complex biological fluids on the surface and structure of nanoparticles is a rapidly expanding field of study. One of the challenges holding back this research is the difficulty of recovering therapeutic nanoparticles from biological samples due to their small size, low density, and stealth surface coatings. Here we present the first demonstration of the recovery and analysis of drug delivery nanoparticles from undiluted human plasma samples through the use of a new electrokinetic platform technology. The particles are recovered from plasma through a dielectrophoresis separation force that is created by innate differences in the dielectric properties between the unaltered nanoparticles and the surrounding plasma. We show this can be applied to a wide range of drug delivery nanoparticles of different morphologies and materials, including low density nano-liposomes. These recovered particles can then be analyzed using different methods including scanning electron microscopy to monitor surface and structural changes that result from plasma exposure. We believe that this new recovery technique is broadly applicable to the recovery of nanoparticles from high conductance fluids in a wide range of applications. PMID:26274918

  16. Automated processing of whole blood samples into microliter aliquots of plasma.

    PubMed

    Burtis, C A; Johnson, W W; Walker, W A

    1988-01-01

    A rotor that accepts and automatically processes a bulk aliquot of a single blood sample into multiple aliquots of plasma has been designed and built. The rotor consists of a central processing unit, which includes a disk containing eight precision-bore capillaries. By varying the internal diameters of the capillaries, aliquot volumes ranging 1 to 10 mul can be prepared. In practice, an unmeasured volume of blood is placed in a centre well, and, as the rotor begins to spin, is moved radially into a central annular ring where it is distributed into a series of processing chambers. The rotor is then spun at 3000 rpm for 10 min. When the centrifugal field is removed by slowly decreasing the rotor speed, an aliquot of plasma is withdrawn by capillary action into each of the capillary tubes. The disk containing the eight measured aliquots of plasma is subsequently removed and placed in a modifed rotor for conventional centrifugal analysis. Initial evaluation of the new rotor indicates that it is capable of producing discrete, microliter volumes of plasma with a degree of accuracy and precision approaching that of mechanical pipettes.

  17. Bacterial adhesion on conventional and self-ligating metallic brackets after surface treatment with plasma-polymerized hexamethyldisiloxane

    PubMed Central

    Tupinambá, Rogerio Amaral; Claro, Cristiane Aparecida de Assis; Pereira, Cristiane Aparecida; Nobrega, Celestino José Prudente; Claro, Ana Paula Rosifini Alves

    2017-01-01

    ABSTRACT Introduction: Plasma-polymerized film deposition was created to modify metallic orthodontic brackets surface properties in order to inhibit bacterial adhesion. Methods: Hexamethyldisiloxane (HMDSO) polymer films were deposited on conventional (n = 10) and self-ligating (n = 10) stainless steel orthodontic brackets using the Plasma-Enhanced Chemical Vapor Deposition (PECVD) radio frequency technique. The samples were divided into two groups according to the kind of bracket and two subgroups after surface treatment. Scanning Electron Microscopy (SEM) analysis was performed to assess the presence of bacterial adhesion over samples surfaces (slot and wings region) and film layer integrity. Surface roughness was assessed by Confocal Interferometry (CI) and surface wettability, by goniometry. For bacterial adhesion analysis, samples were exposed for 72 hours to a Streptococcus mutans solution for biofilm formation. The values obtained for surface roughness were analyzed using the Mann-Whitney test while biofilm adhesion were assessed by Kruskal-Wallis and SNK test. Results: Significant statistical differences (p< 0.05) for surface roughness and bacterial adhesion reduction were observed on conventional brackets after surface treatment and between conventional and self-ligating brackets; no significant statistical differences were observed between self-ligating groups (p> 0.05). Conclusion: Plasma-polymerized film deposition was only effective on reducing surface roughness and bacterial adhesion in conventional brackets. It was also noted that conventional brackets showed lower biofilm adhesion than self-ligating brackets despite the absence of film. PMID:28902253

  18. IL8 and IL16 levels indicate serum and plasma quality.

    PubMed

    Kofanova, Olga; Henry, Estelle; Quesada, Rocio Aguilar; Bulla, Alexandre; Linares, Hector Navarro; Lescuyer, Pierre; Shea, Kathi; Stone, Mars; Tybring, Gunnel; Bellora, Camille; Betsou, Fay

    2018-02-09

    Longer pre-centrifugation times alter the quality of serum and plasma samples. Markers for such delays in sample processing and hence for the sample quality, have been identified. Twenty cytokines in serum, EDTA plasma and citrate plasma samples were screened for changes in concentration induced by extended blood pre-centrifugation delays at room temperature. The two cytokines that showed the largest changes were further validated for their "diagnostic performance" in identifying serum or plasma samples with extended pre-centrifugation times. In this study, using R&D Systems ELISA kits, EDTA plasma samples and serum samples with a pre-centrifugation delay longer than 24 h had an IL16 concentration higher than 313 pg/mL, and an IL8 concentration higher than 125 pg/mL, respectively. EDTA plasma samples with a pre-centrifugation delay longer than 48 h had an IL16 concentration higher than 897 pg/mL, citrate plasma samples had an IL8 concentration higher than 21.5 pg/mL and serum samples had an IL8 concentration higher than 528 pg/mL. These robust and accurate tools, based on simple and commercially available ELISA assays can greatly facilitate qualification of serum and plasma legacy collections with undocumented pre-analytics.

  19. Hand-held portable desorption atmospheric pressure chemical ionization ion source for in situ analysis of nitroaromatic explosives.

    PubMed

    Jjunju, Fred P M; Maher, Simon; Li, Anyin; Syed, Sarfaraz U; Smith, Barry; Heeren, Ron M A; Taylor, Stephen; Cooks, R Graham

    2015-10-06

    A novel, lightweight (0.6 kg), solvent- and gas-cylinder-free, hand-held ion source based on desorption atmospheric pressure chemical ionization has been developed and deployed for the analysis of nitroaromatic explosives on surfaces in open air, offering portability for in-field analysis. A small, inexpensive, rechargeable lithium polymer battery was used to power the custom-designed circuitry within the device, which generates up to ±5 kV dc voltage to ignite a corona discharge plasma in air for up to 12 h of continuous operation, and allowing positive- and negative-ion mass spectrometry. The generated plasma is pneumatically transported to the surface to be interrogated by ambient air at a rate of 1-3.5 L/min, compressed using a small on-board diaphragm pump. The plasma source allows liquid or solid samples to be examined almost instantaneously without any sample preparation in the open environment. The advantages of low carrier gas and low power consumption (<6 W), as well as zero solvent usage, have aided in developing the field-ready, hand-held device for trigger-based, "near-real-time" sampling/ionization. Individual nitroaromatic explosives (such as 2,4,6-trinitrotoluene) can be easily detected in amounts as low as 5.8 pg with a linear dynamic range of at least 10 (10-100 pg), a relative standard deviation of ca. 7%, and an R(2) value of 0.9986. Direct detection of several nitroaromatic compounds in a complex mixture without prior sample preparation is demonstrated, and their identities are confirmed by tandem mass spectrometry fragmentation patterns.

  20. Comparative Studies of the Proteome, Glycoproteome, and N-Glycome of Clear Cell Renal Cell Carcinoma Plasma before and after Curative Nephrectomy

    PubMed Central

    2015-01-01

    Clear cell renal cell carcinoma is the most prevalent of all reported kidney cancer cases, and currently there are no markers for early diagnosis. This has stimulated great research interest recently because early detection of the disease can significantly improve the low survival rate. Combining the proteome, glycoproteome, and N-glycome data from clear cell renal cell carcinoma plasma has the potential of identifying candidate markers for early diagnosis and prognosis and/or to monitor disease recurrence. Here, we report on the utilization of a multi-dimensional fractionation approach (12P-M-LAC) and LC–MS/MS to comprehensively investigate clear cell renal cell carcinoma plasma collected before (disease) and after (non-disease) curative nephrectomy (n = 40). Proteins detected in the subproteomes were investigated via label-free quantification. Protein abundance analysis revealed a number of low-level proteins with significant differential expression levels in disease samples, including HSPG2, CD146, ECM1, SELL, SYNE1, and VCAM1. Importantly, we observed a strong correlation between differentially expressed proteins and clinical status of the patient. Investigation of the glycoproteome returned 13 candidate glycoproteins with significant differential M-LAC column binding. Qualitative analysis indicated that 62% of selected candidate glycoproteins showed higher levels (upregulation) in M-LAC bound fraction of disease samples. This observation was further confirmed by released N-glycans data in which 53% of identified N-glycans were present at different levels in plasma in the disease vs non-disease samples. This striking result demonstrates the potential for significant protein glycosylation alterations in clear cell renal cell carcinoma cancer plasma. With future validation in a larger cohort, information derived from this study may lead to the development of clear cell renal cell carcinoma candidate biomarkers. PMID:25184692

  1. Differential Plasma Glycoproteome of p19 Skin Cancer Mouse Model Using the Corra Label-Free LC-MS Proteomics Platform.

    PubMed

    Letarte, Simon; Brusniak, Mi-Youn; Campbell, David; Eddes, James; Kemp, Christopher J; Lau, Hollis; Mueller, Lukas; Schmidt, Alexander; Shannon, Paul; Kelly-Spratt, Karen S; Vitek, Olga; Zhang, Hui; Aebersold, Ruedi; Watts, Julian D

    2008-12-01

    A proof-of-concept demonstration of the use of label-free quantitative glycoproteomics for biomarker discovery workflow is presented here, using a mouse model for skin cancer as an example. Blood plasma was collected from 10 control mice, and 10 mice having a mutation in the p19(ARF) gene, conferring them high propensity to develop skin cancer after carcinogen exposure. We enriched for N-glycosylated plasma proteins, ultimately generating deglycosylated forms of the modified tryptic peptides for liquid chromatography mass spectrometry (LC-MS) analyses. LC-MS runs for each sample were then performed with a view to identifying proteins that were differentially abundant between the two mouse populations. We then used a recently developed computational framework, Corra, to perform peak picking and alignment, and to compute the statistical significance of any observed changes in individual peptide abundances. Once determined, the most discriminating peptide features were then fragmented and identified by tandem mass spectrometry with the use of inclusion lists. We next assessed the identified proteins to see if there were sets of proteins indicative of specific biological processes that correlate with the presence of disease, and specifically cancer, according to their functional annotations. As expected for such sick animals, many of the proteins identified were related to host immune response. However, a significant number of proteins also directly associated with processes linked to cancer development, including proteins related to the cell cycle, localisation, trasport, and cell death. Additional analysis of the same samples in profiling mode, and in triplicate, confirmed that replicate MS analysis of the same plasma sample generated less variation than that observed between plasma samples from different individuals, demonstrating that the reproducibility of the LC-MS platform was sufficient for this application. These results thus show that an LC-MS-based workflow can be a useful tool for the generation of candidate proteins of interest as part of a disease biomarker discovery effort.

  2. Differential Plasma Glycoproteome of p19ARF Skin Cancer Mouse Model Using the Corra Label-Free LC-MS Proteomics Platform

    PubMed Central

    Letarte, Simon; Brusniak, Mi-Youn; Campbell, David; Eddes, James; Kemp, Christopher J.; Lau, Hollis; Mueller, Lukas; Schmidt, Alexander; Shannon, Paul; Kelly-Spratt, Karen S.; Vitek, Olga; Zhang, Hui; Aebersold, Ruedi; Watts, Julian D.

    2010-01-01

    A proof-of-concept demonstration of the use of label-free quantitative glycoproteomics for biomarker discovery workflow is presented here, using a mouse model for skin cancer as an example. Blood plasma was collected from 10 control mice, and 10 mice having a mutation in the p19ARF gene, conferring them high propensity to develop skin cancer after carcinogen exposure. We enriched for N-glycosylated plasma proteins, ultimately generating deglycosylated forms of the modified tryptic peptides for liquid chromatography mass spectrometry (LC-MS) analyses. LC-MS runs for each sample were then performed with a view to identifying proteins that were differentially abundant between the two mouse populations. We then used a recently developed computational framework, Corra, to perform peak picking and alignment, and to compute the statistical significance of any observed changes in individual peptide abundances. Once determined, the most discriminating peptide features were then fragmented and identified by tandem mass spectrometry with the use of inclusion lists. We next assessed the identified proteins to see if there were sets of proteins indicative of specific biological processes that correlate with the presence of disease, and specifically cancer, according to their functional annotations. As expected for such sick animals, many of the proteins identified were related to host immune response. However, a significant number of proteins also directly associated with processes linked to cancer development, including proteins related to the cell cycle, localisation, trasport, and cell death. Additional analysis of the same samples in profiling mode, and in triplicate, confirmed that replicate MS analysis of the same plasma sample generated less variation than that observed between plasma samples from different individuals, demonstrating that the reproducibility of the LC-MS platform was sufficient for this application. These results thus show that an LC-MS-based workflow can be a useful tool for the generation of candidate proteins of interest as part of a disease biomarker discovery effort. PMID:20157627

  3. Measurement by ICP-MS of lead in plasma and whole blood of lead workers and controls.

    PubMed Central

    Schütz, A; Bergdahl, I A; Ekholm, A; Skerfving, S

    1996-01-01

    OBJECTIVES: To test a simple procedure for preparing samples for measurement of lead in blood plasma (P-Pb) and whole blood (B-Pb) by inductively coupled plasma mass spectrometry (ICP-MS), to measure P-Pb and B-Pb in lead workers and controls, and to evaluate any differences in the relation between B-Pb and P-Pb between people. METHODS: P-Pb and B-Pb were measured by ICP-MS in 43 male lead smelter workers and seven controls without occupational exposure to lead. For analysis, plasma and whole blood were diluted 1 in 4 and 1 in 9, respectively, with a diluted ammonia solution containing Triton-X 100 and EDTA. The samples were handled under routine laboratory conditions, without clean room facilities. RESULTS: P-Pb was measured with good precision (CV = 5%) even at concentrations present in the controls. Freeze storage of the samples had no effect on the results. The detection limit was 0.015 microgram/l. The P-Pb was 0.15 (range 0.1-0.3) microgram/l in controls and 1.2 (0.3-3.6) micrograms/l in lead workers, although the corresponding B-Pbs were 40 (24-59) micrograms/l and 281 (60-530) micrograms/l (1 microgram Pb/I = 4.8 nmol/l). B-Pb was closely associated with P-Pb (r = 0.90). The association was evidently non-linear; the ratio B-Pb/P-Pb decreased with increasing P-Pb. CONCLUSIONS: By means of ICP-MS and a simple dilution procedure, P-Pb may be measured accurately and with good precision down to concentrations present in controls. Contamination of blood at sampling and analysis is no major problem. With increasing P-Pb, the percentage of lead in plasma increases. In studies of lead toxicity, P-Pb should be considered as a complement to current indicators of lead exposure and risk. PMID:9038796

  4. Amplicon-based next-generation sequencing of plasma cell-free DNA for detection of driver and resistance mutations in advanced non-small cell lung cancer.

    PubMed

    Guibert, N; Hu, Y; Feeney, N; Kuang, Y; Plagnol, V; Jones, G; Howarth, K; Beeler, J F; Paweletz, C P; Oxnard, G R

    2018-04-01

    Genomic analysis of plasma cell-free DNA is transforming lung cancer care; however, available assays are limited by cost, turnaround time, and imperfect accuracy. Here, we study amplicon-based plasma next-generation sequencing (NGS), rather than hybrid-capture-based plasma NGS, hypothesizing this would allow sensitive detection and monitoring of driver and resistance mutations in advanced non-small cell lung cancer (NSCLC). Plasma samples from patients with NSCLC and a known targetable genotype (EGFR, ALK/ROS1, and other rare genotypes) were collected while on therapy and analyzed blinded to tumor genotype. Plasma NGS was carried out using enhanced tagged amplicon sequencing of hotspots and coding regions from 36 genes, as well as intronic coverage for detection of ALK/ROS1 fusions. Diagnostic accuracy was compared with plasma droplet digital PCR (ddPCR) and tumor genotype. A total of 168 specimens from 46 patients were studied. Matched plasma NGS and ddPCR across 120 variants from 80 samples revealed high concordance of allelic fraction (R2 = 0.95). Pretreatment, sensitivity of plasma NGS for the detection of EGFR driver mutations was 100% (30/30), compared with 87% for ddPCR (26/30). A full spectrum of rare driver oncogenic mutations could be detected including sensitive detection of ALK/ROS1 fusions (8/9 detected, 89%). Studying 25 patients positive for EGFR T790M that developed resistance to osimertinib, 15 resistance mechanisms could be detected including tertiary EGFR mutations (C797S, Q791P) and mutations or amplifications of non-EGFR genes, some of which could be detected pretreatment or months before progression. This blinded analysis demonstrates the ability of amplicon-based plasma NGS to detect a full range of targetable genotypes in NSCLC, including fusion genes, with high accuracy. The ability of plasma NGS to detect a range of preexisting and acquired resistance mechanisms highlights its potential value as an alternative to single mutation digital PCR-based plasma assays for personalizing treatment of TKI resistance in lung cancer.

  5. Circulating DNA: a potential marker of sickle cell crisis.

    PubMed

    Vasavda, Nisha; Ulug, Pinar; Kondaveeti, Sheila; Ramasamy, Karthik; Sugai, Taku; Cheung, Gordon; Rees, David C; Awogbade, Moji; Bannister, Sybil; Cunningham, Juliette; Menzel, Stephan; Thein, Swee Lay

    2007-10-01

    Free circulating DNA is present in the plasma of healthy subjects, and is elevated in conditions characterized by increased cell death, such as cancer and physical trauma. Analysis of circulating DNA in plasma could provide a useful biomarker in sickle cell disease (SCD) in view of the increased cell turnover through chronic ongoing haemolysis, recurrent vaso-occlusion and inflammation. Plasma DNA was determined by real-time quantitative polymerase chain reaction (PCR) amplification of the beta-globin gene (HBB) in 154 patients with SCD [105 haemoglobin (Hb)SS, 46 HbSC and three HbS/beta(0) thalassaemia] and 53 ethnically matched controls. Blood samples were obtained from all patients in steady state; 21 of the 154 patients were also sampled during admission to hospital for acute pain. Median concentration of circulating plasma DNA in acute pain was more than 10-fold that in steady state and in controls - 10070 vs. 841 and 10070 vs. 933 genome equivalents/ml respectively (P < 0.0001, in both cases). During steady state, patients had plasma DNA levels similar to controls. Plasma DNA levels in SCD correlated with C-reactive protein levels (P < 0.005) and total white cell counts (P < 0.05) in steady state. The study shows that plasma DNA concentration may have potential as a biomarker in sickle cell patients.

  6. Application of inductively coupled plasma sector field mass spectrometry for low-level environmental americium-241 analysis.

    PubMed

    Varga, Zsolt

    2007-03-28

    An improved and novel sample preparation method for (241)Am analysis by inductively coupled plasma sector field mass spectrometry has been developed. The procedure involves a selective CaF(2) pre-concentration followed by an extraction chromatographic separation using TRU resin. The achieved absolute detection limit of 0.86 fg (0.11 mBq) is comparable to that of alpha spectrometry (0.1 mBq) and suitable for low-level environmental measurements. Analysis of different kinds of environmental standard reference materials (IAEA-384--Fangataufa lagoon sediment, IAEA-385--Irish Sea sediment and IAEA-308--Mixed seaweed from the Mediterranean Sea) and alpha spectrometry were used to validate the procedure. The chemical recovery of sample preparation ranged between 72 and 94%. The results obtained are in good agreement with reference values and those measured by alpha spectrometry. The proposed method offers a rapid and less labor-intensive possibility for environmental (241)Am analysis than the conventionally applied radioanalytical techniques.

  7. A simplified and efficient method for the analysis of fatty acid methyl esters suitable for large clinical studies.

    PubMed

    Masood, Athar; Stark, Ken D; Salem, Norman

    2005-10-01

    Conventional sample preparation for fatty acid analysis is a complicated, multiple-step process, and gas chromatography (GC) analysis alone can require >1 h per sample to resolve fatty acid methyl esters (FAMEs). Fast GC analysis was adapted to human plasma FAME analysis using a modified polyethylene glycol column with smaller internal diameters, thinner stationary phase films, increased carrier gas linear velocity, and faster temperature ramping. Our results indicated that fast GC analyses were comparable to conventional GC in peak resolution. A conventional transesterification method based on Lepage and Roy was simplified to a one-step method with the elimination of the neutralization and centrifugation steps. A robotics-amenable method was also developed, with lower methylation temperatures and in an open-tube format using multiple reagent additions. The simplified methods produced results that were quantitatively similar and with similar coefficients of variation as compared with the original Lepage and Roy method. The present streamlined methodology is suitable for the direct fatty acid analysis of human plasma, is appropriate for research studies, and will facilitate large clinical trials and make possible population studies.

  8. Controllable synthesizing DLC nano structures as a super hydrophobic layer on cotton fabric using a low-cost ethanol electrospray-assisted atmospheric plasma jet.

    PubMed

    Sohbatzadeh, F; Eshghabadi, M; Mohsenpour, T

    2018-06-29

    The surface modification of cotton samples was carried out using a liquid (ethanol) electrospray-assisted atmospheric pressure plasma jet. X-ray photoelectron spectroscopy (XPS) and Raman analysis confirmed the successful deposition of diamond like carbon (DLC) nano structures on the cotton surface. The super hydrophobic state of the samples was probed by contact angle measurements. The water repellency of the layers was tuned by controlling the voltage applied to the electrospray electrode. An investigation of the morphological and chemical structures of the samples by field emission scanning microscopy, atomic force microscopy (AFM) and XPS indicated that the physical shape, distribution and amorphization of the DLC structures were successfully adjusted and improved by applying a voltage to the electrospray electrode. Finally wash durability of the best sample was tested for 35 cycles. In this work, the use of a well-developed atmospheric pressure plasma jet for DLC nano structures deposition can enable a promising environmentally friendly and low-cost approach for modifying cotton fabrics for super water-repellent fabric applications.

  9. Controllable synthesizing DLC nano structures as a super hydrophobic layer on cotton fabric using a low-cost ethanol electrospray-assisted atmospheric plasma jet

    NASA Astrophysics Data System (ADS)

    Sohbatzadeh, F.; Eshghabadi, M.; Mohsenpour, T.

    2018-06-01

    The surface modification of cotton samples was carried out using a liquid (ethanol) electrospray-assisted atmospheric pressure plasma jet. X-ray photoelectron spectroscopy (XPS) and Raman analysis confirmed the successful deposition of diamond like carbon (DLC) nano structures on the cotton surface. The super hydrophobic state of the samples was probed by contact angle measurements. The water repellency of the layers was tuned by controlling the voltage applied to the electrospray electrode. An investigation of the morphological and chemical structures of the samples by field emission scanning microscopy, atomic force microscopy (AFM) and XPS indicated that the physical shape, distribution and amorphization of the DLC structures were successfully adjusted and improved by applying a voltage to the electrospray electrode. Finally wash durability of the best sample was tested for 35 cycles. In this work, the use of a well-developed atmospheric pressure plasma jet for DLC nano structures deposition can enable a promising environmentally friendly and low-cost approach for modifying cotton fabrics for super water-repellent fabric applications.

  10. Total plasma proANP increases with atrial dilatation in horses.

    PubMed

    Van Der Vekens, N; Hunter, I; Timm, A; Decloedt, A; De Clercq, D; Deprez, P; Goetze, J P; van Loon, G

    2015-12-19

    Equine atrial natriuretic peptide (ANP) plasma concentrations are correlated with left atrial size. However, species-specific assays are lacking and the results from human assays are poorly reproducible. A new methodology called processing independent analysis (PIA) that measures the total proANP product in plasma has proven to be successful in human medicine, but has never been used in horses. The aims were to establish an equine proANP reference interval by measurement of the total proANP product using PIA and to examine the proANP concentrations in horses with atrial dilatation. Sample stability was studied by comparison of storage at -80°C and -20°C. Plasma samples were obtained from 23 healthy horses, 12 horses with moderate or severe valvular regurgitation without atrial dilatation and 42 horses with valvular regurgitation and atrial dilatation. The proANP concentration was significantly (P<0.001) higher in horses with atrial dilatation (761.4 (442.1-1859.1) pmol/l) than in healthy horses (491.6 (429.5-765.9) pmol/l; P<0.001) or horses with cardiac disease but without atrial dilatation (544.4 (457.0-677.6) pmol/l). A cut-off value (573.8 pmol/l) for detection of atrial dilatation was calculated. Sample storage at -80°C did not differ from sample storage at -20°C. The measurement of total proANP in plasma detects atrial dilatation in horses and may be useful for clinical evaluation in equine medicine. British Veterinary Association.

  11. Plasma beta-endorphin levels in obese and non-obese patients with polycystic ovary disease.

    PubMed

    Martínez-Guisasola, J; Guerrero, M; Alonso, F; Díaz, F; Cordero, J; Ferrer, J

    2001-02-01

    The aim of this study was to determine the influence of body weight on circulating plasma levels of beta-endorphin and insulin in women with polycystic ovary disease (PCOD), as well as the correlation between the plasma levels of beta-endorphin and insulin. One-hundred and sixty-seven consecutive subjects with PCOD were recruited, 117 of whom had normal weight (body mass index (BMI) < 25) while 50 were obese (BMI > 25). A venous blood sample was taken and plasma concentrations of beta-endorphin, insulin, gonadotropins, prolactin, progesterone, 17 beta-estradiol, estrone, androgens, dehydroepiandrosterone sulfate and sex hormone-binding globulin (SHBG) were measured. Mean beta-endorphin and insulin plasma levels were significantly higher (p < 0.05) in obese PCOD women than in non-obese ones. Correlation analysis showed a positive association between insulin and beta-endorphin, beta-endorphin and BMI (and weight), insulin and BMI (and weight), and a negative correlation was found between insulin and SHBG. A weak association was found between beta-endorphin and luteinizing hormone (LH) in peripheral plasma. Stratified and linear regression analysis showed that plasma beta-endorphin concentrations correlate more with BMI than with insulinemia.

  12. Application of dispersive liquid-liquid microextraction for the preconcentration of eight parabens in real samples and their determination by high-performance liquid chromatography.

    PubMed

    Shen, Xiong; Liang, Jian; Zheng, Luxia; Lv, Qianzhou; Wang, Hong

    2017-11-01

    A simple and sensitive method for the simultaneous determination of eight parabens in human plasma and urine samples was developed. The samples were preconcentrated using dispersive liquid-liquid microextraction based on the solidification of floating organic drops and determined by high-performance liquid chromatography with ultraviolet detection. The influence of variables affecting the extraction efficiency was investigated and optimized using Placket-Burman design and Box-Behnken design. The optimized values were: 58 μL of 1-decanol (as extraction solvent), 0.65 mL methanol (as disperser solvent), 1.5% w/v NaCl in 5.0 mL of sample solution, pH 10.6, and 4.0 min centrifugation at 4000 rpm. The extract was injected into the high-performance liquid chromatography system for analysis. Under the optimum conditions, the linear ranges for eight parabens in plasma and urine were 1.0-1000 ng/mL, with correlation coefficients above 0.994. The limit of detection was 0.2-0.4 and 0.1-0.4 ng/mL for plasma and urine samples, respectively. Relative recoveries were between 80.3 and 110.7%, while relative standard deviations were less than 5.4%. Finally, the method was applied to analyze the parabens in 98 patients of primary breast cancer. Results showed that parabens existed widely, at least one paraben detected in 96.9% (95/98) of plasma samples and 98.0% (96/98) of urine samples. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  13. Derivatization of beta-dicarbonyl compound with 2,4-dinitrophenylhydrazine to enhance mass spectrometric detection: application in quantitative analysis of houttuynin in human plasma.

    PubMed

    Duan, Xiaotao; Zhong, Dafang; Chen, Xiaoyan

    2008-06-01

    Houttuynin (decanoyl acetaldehyde), a beta-dicarbonyl compound, is the major antibacterial constituent in the volatile oil of Houttuynina cordata Thunb. In the present work, detection of houttuynin in human plasma based on the chemical derivatization with 2,4-dinitrophenylhydrazine (DNPH) coupled with liquid chromatography/tandem mass spectrometry was described. The primary reaction products between the beta-dicarbonyl compound and DNPH in aqueous phase were identified as heterocyclic structures, of which the mass spectrometric ionization and fragmentation behavior were characterized with the aid of high-resolution multistage mass spectral analysis. For quantification, houttuynin and internal standard (IS, benzophenone) in plasma were firstly converted to their DNPH derivatives without sample purification, then extracted from human plasma with n-hexane and detected by liquid chromatography tandem mass spectrometry performed in selected reaction monitoring (SRM) mode. This method allowed for a lower limit of quantification (LLOQ) of 1.0 ng/ml using 100-microl plasma. The validation results showed high accuracy (%bias < 2.1) and precision (%CV < 7.2) at broad linear dynamic range (1.0-5000 ng/ml). The simple and quantitative derivatization coupled with tandem mass spectrometric analysis facilitates a sensitive and robust method for the determination of plasma houttuynin in pharmacokinetic studies.

  14. Prostatic origin of a zinc binding high molecular weight protein complex in human seminal plasma.

    PubMed

    Siciliano, L; De Stefano, C; Petroni, M F; Vivacqua, A; Rago, V; Carpino, A

    2000-03-01

    The profile of the zinc ligand high molecular weight proteins was investigated in the seminal plasma of 55 normozoospermic subjects by size exclusion high performance liquid chromatography (HPLC). The proteins were recovered from Sephadex G-75 gel filtration of seminal plasma in three zinc-containing fractions which were then submitted to HPLC analysis. The results were, that in all the samples, the protein profiles showed two peaks with apparent molecular weight of approximately 660 and approximately 250 kDa. Dialysis experiments revealed that both approximately 660 and approximately 250 kDa proteins were able to uptake zinc against gradient indicating their zinc binding capacity. The HPLC analysis of the whole seminal plasma evidenced only the approximately 660 kDa protein complex as a single well quantifying peak, furthermore a positive correlation between its peak area and the seminal zinc values (P < 0.001) was observed. This suggested a prostatic origin of the approximately 660 kDa protein complex which was then confirmed by the seminal plasma HPLC analysis of a subject with agenesis of the Wolffian ducts. Finally the study demonstrated the presence of two zinc binding proteins, approximately 660 and approximately 250 kDa respectively, in human seminal plasma and the prostatic origin of the approximately 660 kDa.

  15. Metabolic profiling of body fluids and multivariate data analysis.

    PubMed

    Trezzi, Jean-Pierre; Jäger, Christian; Galozzi, Sara; Barkovits, Katalin; Marcus, Katrin; Mollenhauer, Brit; Hiller, Karsten

    2017-01-01

    Metabolome analyses of body fluids are challenging due pre-analytical variations, such as pre-processing delay and temperature, and constant dynamical changes of biochemical processes within the samples. Therefore, proper sample handling starting from the time of collection up to the analysis is crucial to obtain high quality samples and reproducible results. A metabolomics analysis is divided into 4 main steps: 1) Sample collection, 2) Metabolite extraction, 3) Data acquisition and 4) Data analysis. Here, we describe a protocol for gas chromatography coupled to mass spectrometry (GC-MS) based metabolic analysis for biological matrices, especially body fluids. This protocol can be applied on blood serum/plasma, saliva and cerebrospinal fluid (CSF) samples of humans and other vertebrates. It covers sample collection, sample pre-processing, metabolite extraction, GC-MS measurement and guidelines for the subsequent data analysis. Advantages of this protocol include: •Robust and reproducible metabolomics results, taking into account pre-analytical variations that may occur during the sampling process•Small sample volume required•Rapid and cost-effective processing of biological samples•Logistic regression based determination of biomarker signatures for in-depth data analysis.

  16. Gas-phase detection of solid-state fission product complexes for post-detonation nuclear forensic analysis

    DOE PAGES

    Stratz, S. Adam; Jones, Steven A.; Oldham, Colton J.; ...

    2016-06-27

    This study presents the first known detection of fission products commonly found in post-detonation nuclear debris samples using solid sample introduction and a uniquely coupled gas chromatography inductively-coupled plasma time-of-flight mass spectrometer. Rare earth oxides were chemically altered to incorporate a ligand that enhances the volatility of the samples. These samples were injected (as solids) into the aforementioned instrument and detected for the first time. Repeatable results indicate the validity of the methodology, and this capability, when refined, will prove to be a valuable asset for rapid post-detonation nuclear forensic analysis.

  17. Gas-phase detection of solid-state fission product complexes for post-detonation nuclear forensic analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stratz, S. Adam; Jones, Steven A.; Oldham, Colton J.

    This study presents the first known detection of fission products commonly found in post-detonation nuclear debris samples using solid sample introduction and a uniquely coupled gas chromatography inductively-coupled plasma time-of-flight mass spectrometer. Rare earth oxides were chemically altered to incorporate a ligand that enhances the volatility of the samples. These samples were injected (as solids) into the aforementioned instrument and detected for the first time. Repeatable results indicate the validity of the methodology, and this capability, when refined, will prove to be a valuable asset for rapid post-detonation nuclear forensic analysis.

  18. Profiling of tryptophan-related plasma indoles in patients with carcinoid tumors by automated, on-line, solid-phase extraction and HPLC with fluorescence detection.

    PubMed

    Kema, I P; Meijer, W G; Meiborg, G; Ooms, B; Willemse, P H; de Vries, E G

    2001-10-01

    Profiling of the plasma indoles tryptophan, 5-hydroxytryptophan (5-HTP), serotonin, and 5-hydroxyindoleacetic acid (5-HIAA) is useful in the diagnosis and follow-up of patients with carcinoid tumors. We describe an automated method for the profiling of these indoles in protein-containing matrices as well as the plasma indole concentrations in healthy controls and patients with carcinoid tumors. Plasma, cerebrospinal fluid, and tissue homogenates were prepurified by automated on-line solid-phase extraction (SPE) in Hysphere Resin SH SPE cartridges containing strong hydrophobic polystyrene resin. Analytes were eluted from the SPE cartridge by column switching. Subsequent separation and detection were performed by reversed-phase HPLC combined with fluorometric detection in a total cycle time of 20 min. We obtained samples from 14 healthy controls and 17 patients with metastasized midgut carcinoid tumors for plasma indole analysis. In the patient group, urinary excretion of 5-HIAA and serotonin was compared with concentrations of plasma indoles. Within- and between-series CVs for indoles in platelet-rich plasma were 0.6-6.2% and 3.7-12%, respectively. Results for platelet-rich plasma serotonin compared favorably with those obtained by single-component analysis. Plasma 5-HIAA, but not 5-HTP was detectable in 8 of 17 patients with carcinoid tumors. In the patient group, platelet-rich plasma total tryptophan correlated negatively with platelet-rich plasma serotonin (P = 0.021; r = -0.56), urinary 5-HIAA (P = 0.003; r = -0.68), and urinary serotonin (P <0.0001; r = -0.80). The present chromatographic approach reduces analytical variation and time needed for analysis and gives more detailed information about metabolic deviations in indole metabolism than do manual, single-component analyses.

  19. Human herpesvirus infections of the central nervous system: laboratory diagnosis based on DNA detection by nested PCR in plasma and cerebrospinal fluid samples.

    PubMed

    Rimério, Carla Aparecida Tavares; De Oliveira, Renato Souza; de Almeida Bonatelli, Murilo Queiroz; Nucci, Anamarli; Costa, Sandra Cecília Botelho; Bonon, Sandra Helena Alves

    2015-04-01

    Infections of the central nervous systems (CNS) present a diagnostic problem for which an accurate laboratory diagnosis is essential. Invasive practices, such as cerebral biopsy, have been replaced by obtaining a polymerase chain reaction (PCR) diagnosis using cerebral spinal fluid (CSF) as a reference method. Tests on DNA extracted from plasma are noninvasive, thus avoiding all of the collateral effects and patient risks associated with CSF collection. This study aimed to determine whether plasma can replace CSF in nested PCR analysis for the detection of CNS human herpesvirus (HHV) diseases by analysing the proportion of patients whose CSF nested PCR results were positive for CNS HHV who also had the same organism identified by plasma nested PCR. In this study, CSF DNA was used as the "gold standard," and nested PCR was performed on both types of samples. Fifty-two patients with symptoms of nervous system infection were submitted to CSF and blood collection. For the eight HHV, one positive DNA result-in plasma and/or CSF nested PCR-was considered an active HHV infection, whereas the occurrence of two or more HHVs in the same sample was considered a coinfection. HHV infections were positively detected in 27/52 (51.9%) of the CSF and in 32/52 (61.5%) of the plasma, difference not significant, thus nested PCR can be performed on plasma instead of CSF. In conclusion, this findings suggest that plasma as a useful material for the diagnosis of cases where there is any difficulty to perform a CSF puncture. © 2015 Wiley Periodicals, Inc.

  20. Development and validation of UHPLC-MS/MS methods for the quantification of colistin in plasma and dried plasma spots.

    PubMed

    Cangemi, Giuliana; Barco, Sebastiano; Castagnola, Elio; Tripodi, Gino; Favata, Fabio; D'Avolio, Antonio

    2016-09-10

    Quantification of colistin in plasma samples may be very useful in optimizing therapy especially in special patients' population. Nevertheless, therapeutic drug monitoring of colistin is still limited probably for the low number of laboratories which perform this analysis and for high shipment costs. We developed and validated new UHPLC-MS/MS methods to quantify colistin in plasma and in dried plasma spots (DPS) collected on dried sample spots devices (DSSD). Colistin A, Colistin B and polimixin B, used as internal standard, were detected using multiple reaction monitoring (MRM) of the following specific transitions: 585.5→534.9; 576, 578.5→527.9; 568.9 and 602.5→100.9, 551.9, 592.8, respectively. Colistin A and B were extracted from plasma using protein precipitation and from DSSD using an extraction basic solution. Both methods were validated, and the mean intra and inter-day accuracies and precisions were in accordance with FDA and EMA guidelines. Colistin in DPS was found to be stable for at least one week at room temperature (20-25°C). A statistically significant linear correlation was found between colistin extracted from plasma and from DPS [r(2) 0.9864 (P<0.0001, 95% CI 0.9699-0.9939) for colistin A and 0.9695 (P<0.0001, 95% CI 0.9310-0.9866) for colistin B, respectively]. DPS on DSSD represents a safe and cheap strategy to store and ship at room temperature plasma samples. Thus, it is suited for pharmacokinetic studies and therapeutic drug monitoring of colistin. Copyright © 2016 Elsevier B.V. All rights reserved.

  1. Effect of ELMs on deuterium-loaded-tungsten plasma facing components

    NASA Astrophysics Data System (ADS)

    Umstadter, K. R.; Rudakov, D. L.; Wampler, W.; Watkins, J. G.; Wong, C. P. C.

    2011-08-01

    Prior heat pulse testing of plasma facing components (PFCs) has been completed in vacuum environments without the presence of background plasma. Edge localized modes (ELMs) will not be this kind of isolated event and one should know the effect of a plasma background during these transients. Heat-pulse experiments have been conducted in the PISCES-A device utilizing laser heating in a divertor-like plasma background. Initial results indicate that the erosion of PFCs is enhanced as compared to heat pulse or plasma only tests. To determine if the enhanced erosion effect is a phenomena only witnessed in the laboratory PISCES device, tungsten and graphite samples were exposed to plasmas in the lower divertor of the DIII-D tokamak using the Divertor Material Evaluation System (DiMES). Mass loss analysis indicates that materials that contain significant deuterium prior to experiencing a transient heating event will erode faster than those that have no or little retained deuterium.

  2. A comparison of serum and plasma cytokine values using a multiplexed assay in cats.

    PubMed

    Gruen, Margaret E; Messenger, Kristen M; Thomson, Andrea E; Griffith, Emily H; Paradise, Hayley; Vaden, Shelly; Lascelles, B D X

    2016-12-01

    Degenerative joint disease (DJD) is highly prevalent in cats, and pain contributes to morbidity. In humans, alterations of cytokine concentrations have been associated with joint deterioration and pain. Similar changes have not been investigated in cats. Cytokine concentrations can be measured using multiplex technology with small samples of serum or plasma, however, serum and plasma are not interchangeable for most bioassays. Correlations for cytokine concentrations between serum and plasma have not been evaluated in cats. To evaluate the levels of detection and agreement between serum and plasma samples in cats. Paired serum and plasma samples obtained from 38 cats. Blood was collected into anti-coagulant free and EDTA Vacutainer ® tubes, serum or plasma extracted, and samples frozen at -80°C until testing. Duplicate samples were tested using a 19-plex feline cytokine/chemokine magnetic bead panel. Agreement between serum and plasma for many analytes was high, however correlation coefficients ranged from -0.01 to 0.97. Results from >50% of samples were below the lower limit of quantification for both serum and plasma for nine analytes, and for an additional three analytes for plasma only. While serum and plasma agreement was generally good, detection was improved using serum samples. Copyright © 2016 Elsevier B.V. All rights reserved.

  3. Ion mobility spectrometry as a simple and rapid method to measure the plasma propofol concentrations for intravenous anaesthesia monitoring

    NASA Astrophysics Data System (ADS)

    Wang, Xin; Zhou, Qinghua; Jiang, Dandan; Gong, Yulei; Li, Enyou; Li, Haiyang

    2016-11-01

    The plasma propofol concentration is important information for anaesthetists to monitor and adjust the anaesthesia depth for patients during a surgery operation. In this paper, a stand-alone ion mobility spectrometer (IMS) was constructed for the rapid measurement of the plasma propofol concentrations. Without any sample pre-treatment, the plasma samples were dropped on a piece of glass microfiber paper and then introduced into the IMS cell by the thermal desorption directly. Each individual measurement could be accomplished within 1 min. For the plasma propofol concentrations from 1 to 12 μg mL-1, the IMS response was linear with a correlation coefficient R2 of 0.998, while the limit of detection was evaluated to be 0.1 μg mL-1. These measurement results did meet the clinical application requirements. Furthermore, other clinically-often-used drugs, including remifentanil, flurbiprofen and atracurium, were found no significant interference with the qualitative and quantitative analysis of the plasma propofol. The plasma propofol concentrations measured by IMS were correlated well with those measured by the high performance liquid chromatography (HPLC). The results confirmed an excellent agreement between these two methods. Finally, this method was applied to monitor the plasma propofol concentrations for a patient undergoing surgery, demonstrating its capability of anaesthesia monitoring in real clinical environments.

  4. High throughput image cytometry micronucleus assay to investigate the presence or absence of mutagenic effects of cold physical plasma.

    PubMed

    Bekeschus, Sander; Schmidt, Anke; Kramer, Axel; Metelmann, Hans-Robert; Adler, Frank; von Woedtke, Thomas; Niessner, Felix; Weltmann, Klaus-Dieter; Wende, Kristian

    2018-05-01

    Promising cold physical plasma sources have been developed in the field of plasma medicine. An important prerequisite to their clinical use is lack of genotoxic effects in cells. During optimization of one or even different plasma sources for a specific application, large numbers of samples need to be analyzed. There are soft and easy-to-assess markers for genotoxic stress such as phosphorylation of histone H2AX (γH2AX) but only few tests are accredited by the OECD with regard to mutagenicity detection. The micronucleus (MN) assay is among them but often requires manual counting of many thousands of cells per sample under the microscope. A high-throughput MN assay is presented using image flow cytometry and image analysis software. A human lymphocyte cell line was treated with plasma generated with ten different feed gas conditions corresponding to distinct reactive species patterns that were investigated for their genotoxic potential. Several millions of cells were automatically analyzed by a MN quantification strategy outlined in detail in this work. Our data demonstrates the absence of newly formed MN in any feed gas condition using the atmospheric pressure plasma jet kINPen. As positive control, ionizing radiation gave a significant 5-fold increase in micronucleus frequency. Thus, this assay is suitable to assess the genotoxic potential in large sample sets of cells exposed chemical or physical agents including plasmas in an efficient, reliable, and semiautomated manner. Environ. Mol. Mutagen. 59:268-277, 2018. © 2018 Wiley Periodicals, Inc. © 2018 Wiley Periodicals, Inc.

  5. Comparison of the Hologic Aptima HIV-1 Quant Dx Assay to the Roche COBAS Ampliprep/COBAS TaqMan HIV-1 Test v2.0 for the quantification of HIV-1 RNA in plasma samples.

    PubMed

    Schønning, Kristian; Johansen, Kim; Landt, Bodil; Benfield, Thomas; Westh, Henrik

    2017-07-01

    HIV-RNA is the most important parameter for monitoring antiviral treatment in individuals infected with HIV-1. Knowledge of the performance of different tests for the quantification of HIV-1 RNA is therefore important for clinical care. To compare the analytical performance of the Aptima HIV-1 Quant Dx Assay (Aptima) and the COBAS Ampliprep/COBAS TaqMan HIV-1 Test v2.0 (CAPCTMv2) for the quantification of HIV-1 RNA in plasma samples. The performance of the two tests was compared on 216 clinical plasma samples, on dilutions series in seven replicates of five clinical samples of known subtype and on ten replicates of the Acrometrix High and Low Positive Control. Bland-Altman analysis of 130 samples that quantified in both tests did not show indications of gross mis-quantification of either test. A tendency of the Aptima assay to quantify higher at high viral load compared to the CAPCTMv2 was observed in Bland-Altman analysis, by Deming regression (Slope 1.13) and in dilution series of clinical samples. Precision evaluated using the Acrometrix Positive Controls was similar for the High Control (CV: 1.2% vs. 1.3%; Aptima assay vs. CAPCTMv2 test, respectively), but differed for the Low control (CV: 17.9% vs. 7.1%; Aptima assay vs. CAPCTMv2 test, respectively). However, this did not impact clinical categorization of clinical samples at neither the 50 cp/mL nor 200 cp/mL level. The Aptima assay and the CAPCTMv2 test are highly correlated and are useful for monitoring HIV-infected individuals. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. In matrix derivatization of trichloroethylene metabolites in human plasma with methyl chloroformate and their determination by solid-phase microextraction-gas chromatography-electron capture detector.

    PubMed

    Mudiam, Mohana Krishna Reddy; Jain, Rajeev; Varshney, Meenu; Ch, Ratnasekhar; Chauhan, Abhishek; Goyal, Sudhir Kumar; Khan, Haider A; Murthy, R C

    2013-04-15

    Trichloroethylene (TCE) is a common industrial chemical that has been widely used as metal degreaser and for many industrial purposes. In humans, TCE is metabolized into dichloroacetic acid (DCA), trichloroacetic acid (TCA) and trichloroethanol (TCOH). A simple and rapid method has been developed for the quantitative determination of TCE metabolites. The procedure involves the in situ derivatization of TCE metabolites with methyl chloroformate (MCF) directly in diluted plasma samples followed by extraction and analysis with solid-phase microextraction (SPME) coupled to gas chromatography-electron capture detector (GC-ECD). Factors which can influence the efficiency of derivatization such as amount of MCF and pyridine (PYR), ratio of water/methanol were optimized. The factors which can affect the extraction efficiencies of SPME were screened using 2(7-4) Placket-Burman Design (PBD). A central composite design (CCD) was then applied to further optimize the most significant factors for optimum SPME extraction. The optimum factors for the SPME extraction were found to be 562.5mg of NaCl, pH at 1 and an extraction time of 22 min. Recoveries and detection limits of all three analytes in plasma were found to be in the range of 92.69-97.55% and 0.036-0.068 μg mL(-1) of plasma, respectively. The correlation coefficients were found to be in the range of 0.990-0.995. The intra- and inter-day precisions for TCE metabolites were found to be in the range of 2.37-4.81% and 5.13-7.61%, respectively. The major advantage of this method is that MCF derivatization allows conversion of TCE metabolites into their methyl esters in very short time (≤30 s) at room temperature directly in the plasma samples, thus makes it a solventless analysis. The method developed was successfully applied to the plasma samples of humans exposed to TCE. Copyright © 2013 Elsevier B.V. All rights reserved.

  7. Determination of PNU-248686A, a novel matrix metalloproteinase inhibitor, in human plasma by liquid chromatography-tandem mass spectrometry, following protein precipitation in the 96-well plate format.

    PubMed

    Frigerio, E; Cenacchi, V; James, C A

    2003-02-14

    A sensitive, specific and high-throughput analytical method for the quantitation of PNU-248686A (I), in human plasma has been developed. I, sodium (2R)-3-[[(4'-chloro(1,1'-biphenyl)-4-yl]sulfonyl]-2-hydroxy-2-[(phenylsulfanyl)methyl] propanoate, is an orally active matrix metalloproteinase (MMP) inhibitor developed for the treatment of solid tumors over-expressing MMPs. Concentrations of I, as free acid, were determined in human plasma by LC-MS-MS after plasma protein precipitation in the 96-well plate format. Aliquots of plasma (50 microl) were placed into the plates and 0.2 ml of methanol was added. The plates were shaken for 5 min and centrifuged at 1500 g for 10 min. Aliquots of 10 microl of the supernatants were then directly injected into the LC-MS-MS system. A Symmetry Shield C. column (50 x 2.1 mm, 3.5 microm) was used to perform the chromatographic analysis. The mobile phase was 5 mM ammonium formate buffer solution pH 5.0-acetonitrile (60:40. v/v) with a flow-rate of 0.3 ml/min. Retention time of I was about 1.2 min. Total cycle time was 2.5 min. MS detection used the Applied Biosystems-MDS Sciex API 3000 with TurbolonSpray interface and single reaction monitoring (461 --> 251 m/z transition) operated in negative ion mode. Calibration curves were constructed by plotting the area of the compound (y) against its concentration (x). A weighed linear regression (weighting factor 1/x(2)) was used to calculate I concentrations in quality control and unknown samples. The method was fully validated over the range of 5.0-5000 ng/ml. The suitability and robustness of the method for in vivo samples was confirmed by analysis of plasma samples from a pilot clinical study.

  8. Experimental Validation Plan for the Xolotl Plasma-Facing Component Simulator Using Tokamak Sample Exposures

    NASA Astrophysics Data System (ADS)

    Chan, V. S.; Wong, C. P. C.; McLean, A. G.; Luo, G. N.; Wirth, B. D.

    2013-10-01

    The Xolotl code under development by PSI-SciDAC will enhance predictive modeling capability of plasma-facing materials under burning plasma conditions. The availability and application of experimental data to compare to code-calculated observables are key requirements to validate the breadth and content of physics included in the model and ultimately gain confidence in its results. A dedicated effort has been in progress to collect and organize a) a database of relevant experiments and their publications as previously carried out at sample exposure facilities in US and Asian tokamaks (e.g., DIII-D DiMES, and EAST MAPES), b) diagnostic and surface analysis capabilities available at each device, and c) requirements for future experiments with code validation in mind. The content of this evolving database will serve as a significant resource for the plasma-material interaction (PMI) community. Work supported in part by the US Department of Energy under GA-DE-SC0008698, DE-AC52-07NA27344 and DE-AC05-00OR22725.

  9. Systematic evaluation of matrix effects in hydrophilic interaction chromatography versus reversed phase liquid chromatography coupled to mass spectrometry.

    PubMed

    Periat, Aurélie; Kohler, Isabelle; Thomas, Aurélien; Nicoli, Raul; Boccard, Julien; Veuthey, Jean-Luc; Schappler, Julie; Guillarme, Davy

    2016-03-25

    Reversed phase liquid chromatography (RPLC) coupled to mass spectrometry (MS) is the gold standard technique in bioanalysis. However, hydrophilic interaction chromatography (HILIC) could represent a viable alternative to RPLC for the analysis of polar and/or ionizable compounds, as it often provides higher MS sensitivity and alternative selectivity. Nevertheless, this technique can be also prone to matrix effects (ME). ME are one of the major issues in quantitative LC-MS bioanalysis. To ensure acceptable method performance (i.e., trueness and precision), a careful evaluation and minimization of ME is required. In the present study, the incidence of ME in HILIC-MS/MS and RPLC-MS/MS was compared for plasma and urine samples using two representative sets of 38 pharmaceutical compounds and 40 doping agents, respectively. The optimal generic chromatographic conditions in terms of selectivity with respect to interfering compounds were established in both chromatographic modes by testing three different stationary phases in each mode with different mobile phase pH. A second step involved the assessment of ME in RPLC and HILIC under the best generic conditions, using the post-extraction addition method. Biological samples were prepared using two different sample pre-treatments, i.e., a non-selective sample clean-up procedure (protein precipitation and simple dilution for plasma and urine samples, respectively) and a selective sample preparation, i.e., solid phase extraction for both matrices. The non-selective pretreatments led to significantly less ME in RPLC vs. HILIC conditions regardless of the matrix. On the contrary, HILIC appeared as a valuable alternative to RPLC for plasma and urine samples treated by a selective sample preparation. Indeed, in the case of selective sample preparation, the compounds influenced by ME were different in HILIC and RPLC, and lower and similar ME occurrence was generally observed in RPLC vs. HILIC for urine and plasma samples, respectively. The complementary of both chromatographic modes was also demonstrated, as ME was observed only scarcely for urine and plasma samples when selecting the most appropriate chromatographic mode. Copyright © 2015 Elsevier B.V. All rights reserved.

  10. NHEXAS PHASE I ARIZONA STUDY--STANDARD OPERATING PROCEDURE FOR EXTRACTION OF METALS FROM SOIL, DUST, AIR FILTER, AND SURFACE AND DERMAL SAMPLES FOR AA (GRAPHITE FURNACE OR FLAME) OR ICP-AES ANALYSIS (BCO-L-3.1)

    EPA Science Inventory

    The purpose of this SOP is to describe the acid digestion of soil, house dust, air filter, and surface or dermal wipe samples for analysis using inductively coupled plasma atomic emissions spectrometry (ICP-AES) and/or graphite furnace atomic absorption spectrometry (GFAAS) or fl...

  11. Development and validation of a sensitive assay for analysis of midazolam, free and conjugated 1-hydroxymidazolam and 4-hydroxymidazolam in pediatric plasma: Application to Pediatric Pharmacokinetic Study.

    PubMed

    Moorthy, Ganesh S; Jogiraju, Harini; Vedar, Christina; Zuppa, Athena F

    2017-11-01

    Pharmacokinetic, pharmacodynamic and pharmacogenomic studies of midazolam are currently being performed in critically ill children to find suitable dose regimens. Sensitive assays using small volumes of plasma are necessary to determine the concentrations of midazolam and its respective metabolites in pediatric studies. Midazolam is metabolized to hydroxylated midazolam isomers, which are present as free as well as the corresponding glucuronide conjugates. A high-performance liquid chromatographic method with tandem mass spectrometry has been developed and validated for the quantification of midazolam, and free and total 1-hydroxymidazolam and 4-hydroxymidazolam metabolites in small volumes of plasma. Cleanup consisted of 96-well μ-elution solid phase extraction (SPE). The analytes were separated by gradient elution using a C 18 analytical column with a total run time of 5min. Multiple reaction monitoring was employed using precursor to product ion transitions of m/z 326.2→291.3 for midazolam, m/z 342.1→203.0 for 1-hydroxymidazolam, m/z 342.1→325.1 for 4-hydroxymidazolam and m/z 330.2→295.3 for 2 H 4 -midazolam (internal standard). Since authentic hydroxymidazolamglucuronide standards are not available, samples were hydrolyzed with β-glucuronidase under optimized conditions. Assay conditions were modified and optimized to provide appropriate recovery and stability because 4-hydroxymidazolam was very acid sensitive. Standard curves were linear from 0.5 to 1000ng/mL for all three analytes. Intra- and inter day accuracy and precision for quality control samples (2, 20, 200 and 800ng/mL) were within 85-115% and 15% (coefficient of variation), respectively. Stability in plasma and extracts were sufficient under assay conditions. Plasma samples were processed and analyzed for midazolam, and free 1-hydroxymidazolam and 4-hydroxymidazolam metabolites. Plasma samples that were hydrolyzed with β-glucuronidase were processed and analyzed for midazolam, and total 1-hydroxymidazolam and 4-hydroxymidazolam metabolites under the same assay conditions. The difference in concentration between the total and free hydroxymidazolam metabolites provided an estimate of conjugated hydroxymidazolam metabolites. The combination of 96-well μ-elution SPE and LC-MS/MS allows reliable quantification of midazolam and its metabolites in small volumes of plasma for pediatric patients. This assay is currently being successfully utilized for analysis of samples from ongoing clinical trials. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. Mueller matrix polarimetry on plasma sprayed thermal barrier coatings for porosity measurement.

    PubMed

    Luo, David A; Barraza, Enrique T; Kudenov, Michael W

    2017-12-10

    Yttria-stabilized zirconia (YSZ) is the most widely used material for thermal plasma sprayed thermal barrier coatings (TBCs) used to protect gas turbine engine parts in demanding operation environments. The superior material properties of YSZ coatings are related to their internal porosity level. By quantifying the porosity level, tighter control on the spraying process can be achieved to produce reliable coatings. Currently, destructive measurement methods are widely used to measure the porosity level. In this paper, we describe a novel nondestructive approach that is applicable to classify the porosity level of plasma sprayed YSZ TBCs via Mueller matrix polarimetry. A rotating retarder Mueller matrix polarimeter was used to measure the polarization properties of the plasma sprayed YSZ coatings with different porosity levels. From these measurements, it was determined that a sample's measured depolarization ratio is dependent on the sample's surface roughness and porosity level. To this end, we correlate the depolarization ratio with the samples' surface roughness, as measured by a contact profilometer, as well as the total porosity level, in percentage measured using a micrograph and stereological analysis. With the use of this technique, a full-field and rapid measurement of porosity level can be achieved.

  13. A reliable and rapid tool for plasma quantification of 18 psychotropic drugs by ESI tandem mass spectrometry.

    PubMed

    Vecchione, Gennaro; Casetta, Bruno; Chiapparino, Antonella; Bertolino, Alessandro; Tomaiuolo, Michela; Cappucci, Filomena; Gatta, Raffaella; Margaglione, Maurizio; Grandone, Elvira

    2012-01-01

    A simple liquid chromatographic tandem mass spectrometry (LC-MS/MS) method has been developed for simultaneous analysis of 17 basic and one acid psychotropic drugs in human plasma. The method relies on a protein precipitation step for sample preparation and offers high sensitivity, wide linearity without interferences from endogenous matrix components. Chromatography was run on a reversed-phase column with an acetonitrile-H₂O mixture. The quantification of target compounds was performed in multiple reaction monitoring (MRM) and by switching the ionization polarity within the analytical run. A further sensitivity increase was obtained by implementing the functionality "scheduled multiple reaction monitoring" (sMRM) offered by the recent version of the software package managing the instrument. The overall injection interval was less than 5.5 min. Regression coefficients of the calibration curves and limits of quantification (LOQ) showed a good coverage of over-therapeutic, therapeutic and sub-therapeutic ranges. Recovery rates, measured as percentage of recovery of spiked plasma samples, were ≥ 94%. Precision and accuracy data have been satisfactory for a therapeutic drug monitoring (TDM) service as for managing plasma samples from patients receiving psycho-pharmacological treatment. Copyright © 2012 Elsevier B.V. All rights reserved.

  14. Impression of plasma voltage on growth of α-V{sub 2}O{sub 5} nanostructured thin films

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sharma, Rabindar Kumar, E-mail: rkrksharma6@gmail.com; Kumar, Prabhat; Reddy, G. B.

    2015-06-24

    In this communication, we synthesized vanadium pentoxide (α-V{sub 2}O{sub 5}) nanostructured thin films (NST{sub s}) accompanied with nanoflakes/ nanoplates on the Ni-coated glass substrates employing plasma assisted sublimation process (PASP) as a function of plasma voltage (V{sub p}). The effect of plasma voltage on structural, morphological, compositional, and vibrational properties have been studied systematically. The structural analysis divulged that all films deposited at different V{sub p} have pure orthorhombic phase, no impurity phase is detected under resolution limit of XRD and XPS. The morphological studies of samples is carried out by SEM, revealed that features as well as alignment ofmore » V{sub 2}O{sub 5} NST{sub s} is greatly monitored by V{sub p} and the film possessing the best features is obtained at 2500volt. In addition, XPS results reveal that V{sup 5+} oxidation state is the most prominent state in sample V{sub 2}, which represents better stoichiometric nature of film. The vibrational study of all samples is performed by FTIR and strongly support the XRD observations. All the results are in consonance with each other.« less

  15. Quantitative determination of rocuronium in human plasma by liquid chromatography-electrospray ionization mass spectrometry.

    PubMed

    Farenc, C; Enjalbal, C; Sanchez, P; Bressolle, F; Audran, M; Martinez, J; Aubagnac, J L

    2001-02-23

    Liquid chromatography-electrospray ionization mass spectrometry (LC-ESI-MS) was used for the quantification of the neuromuscular blocking agent rocuronium in human plasma. Verapamil was used as internal standard. The samples were subjected to a dichloromethane liquid-liquid extraction after ion pairing of the positively charged ammonium compound with iodide prior to LC-MS. Optimized conditions involved separation on a Symmetry Shield RP-18 column (50 x 2.1 mm, 3.5 microm) using a 15-min gradient from 10 to 90% acetonitrile in water containing 0.1% trifluoroacetic acid at 250 microl/min. Linear detector responses for standards were observed from 25 to 2,000 ng/ml. The extraction recovery averaged 59% for rocuronium and 83% for the internal standard. The limit of quantification (LOQ), using 500 microl of plasma, was 25 ng/ml. Precision ranged from 1.3 to 19% (LOQ), and accuracy was between 92 and 112%. In plasma samples, at 20 and 4 degrees C, rocuronium was stable at physiological pH for 4 h; frozen at -30 degrees C it was stable for at least 75 days. The method was found suitable for the analysis of samples collected during pharmacokinetic investigations in humans.

  16. Analytical and between-subject variation of thrombin generation measured by calibrated automated thrombography on plasma samples.

    PubMed

    Kristensen, Anne F; Kristensen, Søren R; Falkmer, Ursula; Münster, Anna-Marie B; Pedersen, Shona

    2018-05-01

    The Calibrated Automated Thrombography (CAT) is an in vitro thrombin generation (TG) assay that holds promise as a valuable tool within clinical diagnostics. However, the technique has a considerable analytical variation, and we therefore, investigated the analytical and between-subject variation of CAT systematically. Moreover, we assess the application of an internal standard for normalization to diminish variation. 20 healthy volunteers donated one blood sample which was subsequently centrifuged, aliquoted and stored at -80 °C prior to analysis. The analytical variation was determined on eight runs, where plasma from the same seven volunteers was processed in triplicates, and for the between-subject variation, TG analysis was performed on plasma from all 20 volunteers. The trigger reagents used for the TG assays included both PPP reagent containing 5 pM tissue factor (TF) and PPPlow with 1 pM TF. Plasma, drawn from a single donor, was applied to all plates as an internal standard for each TG analysis, which subsequently was used for normalization. The total analytical variation for TG analysis performed with PPPlow reagent is 3-14% and 9-13% for PPP reagent. This variation can be minimally reduced by using an internal standard but mainly for ETP (endogenous thrombin potential). The between-subject variation is higher when using PPPlow than PPP and this variation is considerable higher than the analytical variation. TG has a rather high inherent analytical variation but considerable lower than the between-subject variation when using PPPlow as reagent.

  17. Comparison of Multiplex Suspension Array Large-Panel Kits for Profiling Cytokines and Chemokines in Rheumatoid Arthritis Patients

    PubMed Central

    Khan, Imran H.; Krishnan, V.V.; Ziman, Melanie; Janatpour, Kim; Wun, Ted; Luciw, Paul A.; Tuscano, Joseph

    2015-01-01

    Background Multiplex analysis allows measurements of a large number of analytes simultaneously in each sample. Based on the Luminex multiplex technology (xMAP), kits for measuring multiple cytokines and chemokines (immunomodulators) are commercially available and are useful in investigations on inflammatory diseases. This study evaluated four multiplex kits (Bio-Plex, LINCOplex, Fluorokine, and Beadlyte) that contained 27, 29, 20 and 22 analytes each, respectively, for the analysis of immunomodulators in plasma of rheumatoid arthritis (RA) patients who underwent treatment with antibody against CD20 (rituximab), a B-cell reductive therapy. Methods Multiplex kits were tested on serial plasma samples obtained from six RA patients at baseline and multiple time points (3, 6, and 9 months) post-treatment with rituximab. The RA patients included in this study had previously failed therapy with disease modifying anti-arthritis drugs (DMARD) and treatment with anti-TNFα antibody (infliximab). Results Computer modeling and hierarchical cluster analysis of the multiplex data allowed a comparison of the performance of multiplex assay kits and revealed profiles of immunomodulators in the RA patients. Conclusions In plasma of RA patients who appeared to have benefited from rituximab treatment the profile of significantly elevated immunomodulators by at least two of the three kits (BioPlex, LINCOplex, Beadlyte), is as follows: IL-12p70, Eotaxin, IL-4, TNFα, Il-9, IL-1β, IFNγ, IL-10, IL-6, and IL-13. Immunomodulator profiling by multiplex analysis may provide useful plasma biomarkers for monitoring response to B-cell reductive therapy in RA patients. PMID:18823005

  18. Microwave plasma torch mass spectrometry for the direct detection of copper and molybdenum ions in aqueous liquids.

    PubMed

    Xiong, Xiaohong; Jiang, Tao; Zhou, Runzhi; Wang, Shangxian; Zou, Wei; Zhu, Zhiqiang

    2016-05-01

    Microwave plasma torch (MPT) is a simple and low power-consumption ambient ion source. And the MPT Mass spectra of many metal elements usually exhibit some novel features different from their inductively coupled plasma (ICP) mass spectra, which may be helpful for metal element analysis. Here, we presented the results about the MPT mass spectra of copper and molybdenum elements by a linear ion trap mass spectrometer (LTQ). The generated copper or molybdenum contained ions in plasma were characterized further in collision-induced dissociated (CID) experiments. These researches built a novel, direct and sensitive method for the direct analysis of trace levels of copper and molybdenum in aqueous liquids. Quantitative results showed that the limit of detection (LOD) by using MS(2) procedure was estimated to be 0.265 µg/l (ppb) for copper and 0.497 µg/l for molybdenum. The linear dynamics ranges cover at least 2 orders of magnitude and the analysis of a single aqueous sample can be completed in 5-6 min with a reasonable semi-quantitative sense. Two practical aqueous samples, milk and urine, were also analyzed qualitatively with reasonable recovery rates and RSD. These experimental data demonstrated that the MPT MS is able to turn into a promising and hopeful tool in field analysis of copper and molybdenum ions in water and some aqueous media, and can be applied in many fields, such as environmental controlling, hydrogeology, and water quality inspection. Moreover, MPT MS could also be used as the supplement of ICP-MS for the rapid and in-situ analysis of metal ions. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  19. Comparison of the effect of plasma treatment and gamma ray irradiation on PS-Cu nanocomposite films surface

    NASA Astrophysics Data System (ADS)

    Farag, O. F.

    2018-06-01

    Polystyrene-copper (PS-Cu) nanocomposite films were treated with DC N2 plasma and gamma rays irradiations. The plasma treatment of PS-Cu film surface was carried out at different treatment times, gas pressure 0.4 Torr and the applied power 3.5 W. On the other hand, the treatment with gamma rays irradiation were carried out at irradiation doses 10, 30 and 50 kGy. The induced changes in surface properties of PS-Cu films were investigated with UV-viss spectroscopy, scanning electron microscopy (SEM) and FTIR spectroscopy techniques. In addition, the wettability property, surface free energy, spreading coefficient and surface roughness of the treated samples were studied by measuring the contact angle. The UV-viss spectroscopy analysis revealed that the optical band gap decreases with increasing the treatment time and the irradiation dose for plasma and gamma treatments, respectively. SEM observations showed that the particle size of copper particles was increased with increasing the treatment time and the irradiation dose, but gamma treatment changes the copper particles size from nano scale to micro scale. The contact angle measurements showing that the wettability property, surface free energy, spreading coefficient and surface roughness of the treated PS-Cu samples were increased remarkably with increasing the treatment time and the irradiation dose for plasma and gamma treatments, respectively. The contact angle, surface free energy, spreading coefficient and surface roughness of the treated PS-Cu samples are more influenced by plasma treatment than gamma treatment.

  20. Soil Sample Dissolution Development by Ultrawave Digester, Followed by Isotopic Separation and Analysis

    DTIC Science & Technology

    2017-01-09

    uranium, americium, and thorium were analyzed, along with other transition and rare earth metals, utilizing inductively coupled plasma- mass spectrometry...inductively coupled plasma- mass spectrometry and/or alpha spectrometry, following digestion. For validation of the microwave protocol, radioactive... actinide elements. HF is a hazardous acid to work with and it is highly toxic. In this evaluation and validation, the actinides are of particular

  1. Thermal Degradation of Small Molecules: A Global Metabolomic Investigation.

    PubMed

    Fang, Mingliang; Ivanisevic, Julijana; Benton, H Paul; Johnson, Caroline H; Patti, Gary J; Hoang, Linh T; Uritboonthai, Winnie; Kurczy, Michael E; Siuzdak, Gary

    2015-11-03

    Thermal processes are widely used in small molecule chemical analysis and metabolomics for derivatization, vaporization, chromatography, and ionization, especially in gas chromatography mass spectrometry (GC/MS). In this study the effect of heating was examined on a set of 64 small molecule standards and, separately, on human plasma metabolite extracts. The samples, either derivatized or underivatized, were heated at three different temperatures (60, 100, and 250 °C) at different exposure times (30 s, 60 s, and 300 s). All the samples were analyzed by liquid chromatography coupled to electrospray ionization mass spectrometry (LC/MS) and the data processed by XCMS Online ( xcmsonline.scripps.edu ). The results showed that heating at an elevated temperature of 100 °C had an appreciable effect on both the underivatized and derivatized molecules, and heating at 250 °C created substantial changes in the profile. For example, over 40% of the molecular peaks were altered in the plasma metabolite analysis after heating (250 °C, 300s) with a significant formation of degradation and transformation products. The analysis of 64 small molecule standards validated the temperature-induced changes observed on the plasma metabolites, where most of the small molecules degraded at elevated temperatures even after minimal exposure times (30 s). For example, tri- and diorganophosphates (e.g., adenosine triphosphate and adenosine diphosphate) were readily degraded into a mono-organophosphate (e.g., adenosine monophosphate) during heating. Nucleosides and nucleotides (e.g., inosine and inosine monophosphate) were also found to be transformed into purine derivatives (e.g., hypoxanthine). A newly formed transformation product, oleoyl ethyl amide, was identified in both the underivatized and derivatized forms of the plasma extracts and small molecule standard mixture, and was likely generated from oleic acid. Overall these analyses show that small molecules and metabolites undergo significant time-sensitive alterations when exposed to elevated temperatures, especially those conditions that mimic sample preparation and analysis in GC/MS experiments.

  2. Single-sample method for the estimation of glomerular filtration rate in children

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tauxe, W.N.; Bagchi, A.; Tepe, P.G.

    1987-03-01

    A method for the determination of the glomerular filtration rate (GFR) in children which involves the use of a single-plasma sample (SPS) after the injection of a radioactive indicator such as radioiodine labeled diatrizoate (Hypaque) has been developed. This is analogous to previously published SPS techniques of effective renal plasma flow (ERPF) in adults and children and GFR SPS techniques in adults. As a reference standard, GFR has been calculated from compartment analysis of injected radiopharmaceuticals (Sapirstein Method). Theoretical volumes of distribution were calculated at various times after injection (Vt) by dividing the total injected counts (I) by the plasmamore » concentration (Ct) expressed in liters, determined by counting an aliquot of plasma in a well type scintillation counter. Errors of predicting GFR from the various Vt values were determined as the standard error of estimate (Sy.x) in ml/min. They were found to be relatively high early after injection and to fall to a nadir of 3.9 ml/min at 91 min. The Sy.x Vt relationship was examined in linear, quadratic, and exponential form, but the simpler linear relationship was found to yield the lowest error. Other data calculated from the compartment analysis of the reference plasma disappearance curves are presented, but at this time have apparently little clinical relevance.« less

  3. Hemostatic properties and protein expression profile of therapeutic apheresis plasma treated with amotosalen and ultraviolet A for pathogen inactivation.

    PubMed

    Ohlmann, Philippe; Hechler, Béatrice; Chafey, Philippe; Ravanat, Catherine; Isola, Hervé; Wiesel, Marie-Louise; Cazenave, Jean-Pierre; Gachet, Christian

    2016-09-01

    The INTERCEPT Blood System (IBS) using amotosalen-HCl and ultraviolet (UV)A inactivates a large spectrum of microbial pathogens and white blood cells in therapeutic plasma. Our aim was to evaluate to what extent IBS modifies the capacity of plasma to generate thrombin and induces qualitative or quantitative modifications of plasma proteins. Plasma units from four donors were collected by apheresis. Samples were taken before (control [CTRL]) and after IBS treatment and stored at -80°C until use. The activities of plasma coagulation factors and inhibitors and the thrombin generation potential were determined using assays measuring clotting times and the calibrated automated thrombogram (CAT), respectively. The proteomic profile of plasma proteins was examined using a two-dimensional differential in-gel electrophoresis (2D-DIGE) method. Nearly all of the procoagulant and antithrombotic factors tested retained at least 78% of their initial pre-IBS activity. Only FVII and FVIII displayed a lower level of conservation (67%), which nevertheless remained within the reference range for conventional plasma coagulation factors. The thrombin generation profile of plasma was conserved after IBS treatment. Among the 1331 protein spots revealed by 2D-DIGE analysis, only four were differentially expressed in IBS plasma compared to CTRL plasma and two were identified by mass spectrometric analysis as transthyretin and apolipoprotein A1. The IBS technique for plasma moderately decreases the activities of plasma coagulation factors and antithrombotic proteins, with no impact on the thrombin generation potential of plasma and very limited modifications of the proteomic profile. © 2016 AABB.

  4. Isolation and characterization of the plasma membrane from the yeast Pichia pastoris.

    PubMed

    Grillitsch, Karlheinz; Tarazona, Pablo; Klug, Lisa; Wriessnegger, Tamara; Zellnig, Günther; Leitner, Erich; Feussner, Ivo; Daum, Günther

    2014-07-01

    Despite similarities of cellular membranes in all eukaryotes, every compartment displays characteristic and often unique features which are important for the functions of the specific organelles. In the present study, we biochemically characterized the plasma membrane of the methylotrophic yeast Pichia pastoris with emphasis on the lipids which form the matrix of this compartment. Prerequisite for this effort was the design of a standardized and reliable isolation protocol of the plasma membrane at high purity. Analysis of isolated plasma membrane samples from P. pastoris revealed an increase of phosphatidylserine and a decrease of phosphatidylcholine compared to bulk membranes. The amount of saturated fatty acids in the plasma membrane was higher than in total cell extracts. Ergosterol, the final product of the yeast sterol biosynthetic pathway, was found to be enriched in plasma membrane fractions, although markedly lower than in Saccharomyces cerevisiae. A further characteristic feature of the plasma membrane from P. pastoris was the enrichment of inositol phosphorylceramides over neutral sphingolipids, which accumulated in internal membranes. The detailed analysis of the P. pastoris plasma membrane is discussed in the light of cell biological features of this microorganism especially as a microbial cell factory for heterologous protein production. Copyright © 2014 Elsevier B.V. All rights reserved.

  5. Bile acid profiling and quantification in biofluids using ultra-performance liquid chromatography tandem mass spectrometry.

    PubMed

    Sarafian, Magali H; Lewis, Matthew R; Pechlivanis, Alexandros; Ralphs, Simon; McPhail, Mark J W; Patel, Vishal C; Dumas, Marc-Emmanuel; Holmes, Elaine; Nicholson, Jeremy K

    2015-10-06

    Bile acids are important end products of cholesterol metabolism. While they have been identified as key factors in lipid emulsification and absorption due to their detergent properties, bile acids have also been shown to act as signaling molecules and intermediates between the host and the gut microbiota. To further the investigation of bile acid functions in humans, an advanced platform for high throughput analysis is essential. Herein, we describe the development and application of a 15 min UPLC procedure for the separation of bile acid species from human biofluid samples requiring minimal sample preparation. High resolution time-of-flight mass spectrometry was applied for profiling applications, elucidating rich bile acid profiles in both normal and disease state plasma. In parallel, a second mode of detection was developed utilizing tandem mass spectrometry for sensitive and quantitative targeted analysis of 145 bile acid (BA) species including primary, secondary, and tertiary bile acids. The latter system was validated by testing the linearity (lower limit of quantification, LLOQ, 0.25-10 nM and upper limit of quantification, ULOQ, 2.5-5 μM), precision (≈6.5%), and accuracy (81.2-118.9%) on inter- and intraday analysis achieving good recovery of bile acids (serum/plasma 88% and urine 93%). The ultra performance liquid chromatography-mass spectrometry (UPLC-MS)/MS targeted method was successfully applied to plasma, serum, and urine samples in order to compare the bile acid pool compositional difference between preprandial and postprandial states, demonstrating the utility of such analysis on human biofluids.

  6. Detection of hepatitis B virus infection markers in dried plasma spots among patients in Congo-Brazzaville.

    PubMed

    Alidjinou, Enagnon Kazali; Moukassa, Donatien; Sané, Famara; Twagirimana Nyenyeli, Séraphin; Akoko, Estina Chandrelle; Mountou, Michèle Valy; Bocket, Laurence; Ibara, Jean-Rosaire; Hober, Didier

    2014-03-01

    The detection of hepatitis B virus (HBV) infection markers by using dried plasma spots from 32 patients living in Congo has been assessed. Considering frozen plasma samples as gold standard, the sensitivity and specificity of HBV serologic markers detection in dried plasma eluted from filter paper were 100%. The sensitivity and the specificity of HBV DNA detection reached 96% and 100%, respectively, with plasma samples dried on filter paper compared to standard samples. Dried plasma samples can represent an alternative to conventional sampling for HBV detection and management of the infection in developing countries. Copyright © 2014 Elsevier Inc. All rights reserved.

  7. Quantitation of 87 Proteins by nLC-MRM/MS in Human Plasma: Workflow for Large-Scale Analysis of Biobank Samples.

    PubMed

    Rezeli, Melinda; Sjödin, Karin; Lindberg, Henrik; Gidlöf, Olof; Lindahl, Bertil; Jernberg, Tomas; Spaak, Jonas; Erlinge, David; Marko-Varga, György

    2017-09-01

    A multiple reaction monitoring (MRM) assay was developed for precise quantitation of 87 plasma proteins including the three isoforms of apolipoprotein E (APOE) associated with cardiovascular diseases using nanoscale liquid chromatography separation and stable isotope dilution strategy. The analytical performance of the assay was evaluated and we found an average technical variation of 4.7% in 4-5 orders of magnitude dynamic range (≈0.2 mg/L to 4.5 g/L) from whole plasma digest. Here, we report a complete workflow, including sample processing adapted to 96-well plate format and normalization strategy for large-scale studies. To further investigate the MS-based quantitation the amount of six selected proteins was measured by routinely used clinical chemistry assays as well and the two methods showed excellent correlation with high significance (p-value < 10e-5) for the six proteins, in addition for the cardiovascular predictor factor, APOB: APOA1 ratio (r = 0.969, p-value < 10e-5). Moreover, we utilized the developed assay for screening of biobank samples from patients with myocardial infarction and performed the comparative analysis of patient groups with STEMI (ST- segment elevation myocardial infarction), NSTEMI (non ST- segment elevation myocardial infarction) and type-2 AMI (type-2 myocardial infarction) patients.

  8. Analysis of laser induced plasma of lithium iron phosphate/LiFePO4 using Nd:YAG laser at low pressure

    NASA Astrophysics Data System (ADS)

    Suliyanti, M. M.; Hidayah, A. N.; Isnaeni

    2017-04-01

    Preliminary analysis of lithium in Lithium Iron Phosphate (LiFePO4) powder using laser induced plasma spectroscopy at low pressure had been done. Recently, LiFePO4-based batteries are widely used in most electric cars and bikes due to less toxic. However, lithium (Li) element is very difficult to detect since it is a very light element. In this work, we used a Nd:YAG laser (1064 nm wavelength, 5 ns pulse width at 10 Hz repetition rate) that was focused on LiFePO4 sample at low pressure. The main Li peak emission in LiFePO4 powder and sheet can be easily detected using this technique. We report the results of experimental study on Li element emission lines at wavelength 460.18 nm, 610.37 nm and 670.83 nm using 2 mJ and 12 mJ laser irradiation at 5 Torr and 35 Torr air atmosphere. The results of this study showed promising application of laser-induced plasma spectroscopy to detect and analyse Li in various samples.

  9. Psychotropics and weak opioid analgesics in plasma samples of older hip fracture patients - detection frequencies and consistency with drug records.

    PubMed

    Waade, Ragnhild Birkeland; Molden, Espen; Martinsen, Mette Irene; Hermann, Monica; Ranhoff, Anette Hylen

    2017-07-01

    To determine use of psychotropic drugs and weak opioids in hip fracture patients by analysing plasma samples at admission, and compare detected drug frequencies with prescription registry data and drug records. Plasma from 250 hip fracture patients aged ≥65 years sampled at hospital admission were analysed by ultra-performance liquid chromatography-tandem mass spectrometry methods for detection of psychotropic drugs and weak opioid analgesics (alcohol also determined). Odds ratios for drugs detected in plasma of hip fracture patients vs. prescription frequencies of the same drugs in an age-, time- and region-matched reference population were calculated. Moreover, recorded and measured drugs were compared. Psychotropic drugs and/or weak opioid analgesics were detected in 158 (63%) of the patients (median age 84 years; 76% females), while alcohol was found in 19 patients (7.6%). The occurrence of diazepam (odds ratio 1.6; 95% confidence interval 1.1-2.4), nitrazepam (2.3; 1.3-4.1), selective serotonin reuptake inhibitors (1.9; 1.3-2.9) and mirtazapine (2.3; 1.2-4.3) was significantly higher in plasma samples of hip fracture patients than in prescription data from the reference population. Poor consistency between recorded and measured drugs was disclosed for z-hypnotics and benzodiazepines; e.g. diazepam was detected in 29 (11.6%), but only recorded in six (2.4%) of the patients. Plasma analysis shows that use of antidepressants and benzodiazepines in hip fracture patients is significantly more frequent than respective prescription frequencies in the general elderly population. Moreover, consistency between recorded and actual use of psychotropic fall-risk drugs is poor at hospital admission of hip fracture patients. © 2017 The British Pharmacological Society.

  10. Simultaneous determination of glucose, triglycerides, urea, cholesterol, albumin and total protein in human plasma by Fourier transform infrared spectroscopy: direct clinical biochemistry without reagents.

    PubMed

    Jessen, Torben E; Höskuldsson, Agnar T; Bjerrum, Poul J; Verder, Henrik; Sørensen, Lars; Bratholm, Palle S; Christensen, Bo; Jensen, Lene S; Jensen, Maria A B

    2014-09-01

    Direct measurement of chemical constituents in complex biologic matrices without the use of analyte specific reagents could be a step forward toward the simplification of clinical biochemistry. Problems related to reagents such as production errors, improper handling, and lot-to-lot variations would be eliminated as well as errors occurring during assay execution. We describe and validate a reagent free method for direct measurement of six analytes in human plasma based on Fourier-transform infrared spectroscopy (FTIR). Blood plasma is analyzed without any sample preparation. FTIR spectrum of the raw plasma is recorded in a sampling cuvette specially designed for measurement of aqueous solutions. For each analyte, a mathematical calibration process is performed by a stepwise selection of wavelengths giving the optimal least-squares correlation between the measured FTIR signal and the analyte concentration measured by conventional clinical reference methods. The developed calibration algorithms are subsequently evaluated for their capability to predict the concentration of the six analytes in blinded patient samples. The correlation between the six FTIR methods and corresponding reference methods were 0.87

  11. Green tea catechins and their metabolites in human skin before and after exposure to ultraviolet radiation.

    PubMed

    Clarke, Kayleigh A; Dew, Tristan P; Watson, Rachel E B; Farrar, Mark D; Osman, Joanne E; Nicolaou, Anna; Rhodes, Lesley E; Williamson, Gary

    2016-01-01

    Dietary flavonoids may protect against sunburn inflammation in skin. Preliminary reports using less complete analysis suggest that certain catechins and their metabolites are found in skin biopsies and blister fluid after consumption of green tea; however, it is not known if they are affected by solar-simulated ultraviolet radiation (UVR) or whether conjugated forms, with consequently altered bioactivity, are present. The present study tested the hypothesis that UVR affects the catechin levels in the skin of healthy volunteers after consumption of green tea and how catechins in the plasma are related to their presence in skin tissue samples. In an open oral intervention study, 11 subjects consumed green tea and vitamin C supplements daily for 3months. Presupplementation and postsupplementation plasma samples, suction blister fluid and skin biopsies were collected; the latter two samples were collected both before and after UVR. A sensitive high-performance liquid chromatography/mass spectrometric assay was used to measure the intact catechin metabolites, conjugates and free forms. Seven green tea catechins and their corresponding metabolites were identified postsupplementation in skin biopsies, 20 in blister fluid and 26 in plasma, with 15 green tea catechin metabolites present in both blister fluid and plasma. The valerolactone, O-methyl-M4-O-sulfate, a gut microbiota metabolite of catechins, was significantly increased 1.6-fold by UVR in blister fluid samples. In conclusion, there were some common catechin metabolites in the plasma and blister fluid, and the concentration was always higher in plasma. The results suggest that green tea catechins and metabolites are bioavailable in skin and provide a novel link between catechin metabolites derived from the skin and gut microbiota. Copyright © 2015 The Authors. Published by Elsevier Inc. All rights reserved.

  12. Green tea catechins and their metabolites in human skin before and after exposure to ultraviolet radiation☆☆☆★

    PubMed Central

    Clarke, Kayleigh A.; Dew, Tristan P.; Watson, Rachel E.B.; Farrar, Mark D.; Osman, Joanne E.; Nicolaou, Anna; Rhodes, Lesley E.; Williamson, Gary

    2016-01-01

    Dietary flavonoids may protect against sunburn inflammation in skin. Preliminary reports using less complete analysis suggest that certain catechins and their metabolites are found in skin biopsies and blister fluid after consumption of green tea; however, it is not known if they are affected by solar-simulated ultraviolet radiation (UVR) or whether conjugated forms, with consequently altered bioactivity, are present. The present study tested the hypothesis that UVR affects the catechin levels in the skin of healthy volunteers after consumption of green tea and how catechins in the plasma are related to their presence in skin tissue samples. In an open oral intervention study, 11 subjects consumed green tea and vitamin C supplements daily for 3 months. Presupplementation and postsupplementation plasma samples, suction blister fluid and skin biopsies were collected; the latter two samples were collected both before and after UVR. A sensitive high-performance liquid chromatography/mass spectrometric assay was used to measure the intact catechin metabolites, conjugates and free forms. Seven green tea catechins and their corresponding metabolites were identified postsupplementation in skin biopsies, 20 in blister fluid and 26 in plasma, with 15 green tea catechin metabolites present in both blister fluid and plasma. The valerolactone, O-methyl-M4-O-sulfate, a gut microbiota metabolite of catechins, was significantly increased 1.6-fold by UVR in blister fluid samples. In conclusion, there were some common catechin metabolites in the plasma and blister fluid, and the concentration was always higher in plasma. The results suggest that green tea catechins and metabolites are bioavailable in skin and provide a novel link between catechin metabolites derived from the skin and gut microbiota. PMID:26454512

  13. Simultaneous determination of trimethoprim and sulfamethoxazole in dried plasma and urine spots

    PubMed Central

    Gonzalez, Daniel; Melloni, Chiara; Poindexter, Brenda B; Yogev, Ram; Atz, Andrew M; Sullivan, Janice E; Mendley, Susan R; Delmore, Paula; Delinsky, Amy; Zimmerman, Kanecia; Lewandowski, Andrew; Harper, Barrie; Lewis, Kenneth C; Benjamin, Daniel K; Cohen-Wolkowiez, Michael

    2015-01-01

    Background: Trimethoprim-sulfamethoxazole (TMP-SMX) is an antimicrobial drug combination commonly prescribed in children and adults. The study objectives were to validate and apply an HPLC–MS/MS method to quantify TMP-SMX in dried plasma spots (DPS) and dried urine spots (DUS), and perform a comparability analysis with liquid matrices. Results: For TMP the validated range was 100–50,000 ng/ml for DPS and 500–250,000 ng/ml for DUS; for SMX, the validated range was 1000–500,000 ng/ml for both DPS and DUS. Good agreement was noted between DPS/DUS and liquid plasma and urine samples for TMP, while only modest agreement was observed for SMX in both matrices. Conclusion: A precise, accurate and reproducible method was developed to quantify TMP-SMX in DPS and DUS samples. PMID:26039810

  14. High performance liquid chromatographic assay for the quantitation of total glutathione in plasma

    NASA Technical Reports Server (NTRS)

    Abukhalaf, Imad K.; Silvestrov, Natalia A.; Menter, Julian M.; von Deutsch, Daniel A.; Bayorh, Mohamed A.; Socci, Robin R.; Ganafa, Agaba A.

    2002-01-01

    A simple and widely used homocysteine HPLC procedure was applied for the HPLC identification and quantitation of glutathione in plasma. The method, which utilizes SBDF as a derivatizing agent utilizes only 50 microl of sample volume. Linear quantitative response curve was generated for glutathione over a concentration range of 0.3125-62.50 micromol/l. Linear regression analysis of the standard curve exhibited correlation coefficient of 0.999. Limit of detection (LOD) and limit of quantitation (LOQ) values were 5.0 and 15 pmol, respectively. Glutathione recovery using this method was nearly complete (above 96%). Intra-assay and inter-assay precision studies reflected a high level of reliability and reproducibility of the method. The applicability of the method for the quantitation of glutathione was demonstrated successfully using human and rat plasma samples.

  15. Sensitive method for the quantitation of droloxifene in plasma and serum by high-performance liquid chromatography employing fluorimetric detection.

    PubMed

    Tess, D A; Cole, R O; Toler, S M

    1995-12-15

    A simple and highly sensitive reversed-phase fluorimetric HPLC method for the quantitation of droloxifene from rat, monkey, and human plasma as well as human serum is described. This assay employs solid-phase extraction and has a dynamic range of 25 to 10,000 pg/ml. Sample extraction (efficiencies > 86%) was accomplished using a benzenesulfonic acid (SCX) column with water and methanol rinses. Droloxifene and internal standard were eluted with 1 ml of 3.5% (v/v) ammonium hydroxide (30%) in methanol. Samples were quantitated using post-column UV-photochemical cyclization coupled with fluorimetric detection with excitation and emission wavelengths of 260 nm and 375 nm, respectively. Relative ease of sample extraction and short run times allow for the analysis of approximately 100 samples per day.

  16. Accuracy of recommended sampling and assay methods for the determination of plasma-free and urinary fractionated metanephrines in the diagnosis of pheochromocytoma and paraganglioma: a systematic review.

    PubMed

    Därr, Roland; Kuhn, Matthias; Bode, Christoph; Bornstein, Stefan R; Pacak, Karel; Lenders, Jacques W M; Eisenhofer, Graeme

    2017-06-01

    To determine the accuracy of biochemical tests for the diagnosis of pheochromocytoma and paraganglioma. A search of the PubMed database was conducted for English-language articles published between October 1958 and December 2016 on the biochemical diagnosis of pheochromocytoma and paraganglioma using immunoassay methods or high-performance liquid chromatography with coulometric/electrochemical or tandem mass spectrometric detection for measurement of fractionated metanephrines in 24-h urine collections or plasma-free metanephrines obtained under seated or supine blood sampling conditions. Application of the Standards for Reporting of Diagnostic Studies Accuracy Group criteria yielded 23 suitable articles. Summary receiver operating characteristic analysis revealed sensitivities/specificities of 94/93% and 91/93% for measurement of plasma-free metanephrines and urinary fractionated metanephrines using high-performance liquid chromatography or immunoassay methods, respectively. Partial areas under the curve were 0.947 vs. 0.911. Irrespective of the analytical method, sensitivity was significantly higher for supine compared with seated sampling, 95 vs. 89% (p < 0.02), while specificity was significantly higher for supine sampling compared with 24-h urine, 95 vs. 90% (p < 0.03). Partial areas under the curve were 0.942, 0.913, and 0.932 for supine sampling, seated sampling, and urine. Test accuracy increased linearly from 90 to 93% for 24-h urine at prevalence rates of 0.0-1.0, decreased linearly from 94 to 89% for seated sampling and was constant at 95% for supine conditions. Current tests for the biochemical diagnosis of pheochromocytoma and paraganglioma show excellent diagnostic accuracy. Supine sampling conditions and measurement of plasma-free metanephrines using high-performance liquid chromatography with coulometric/electrochemical or tandem mass spectrometric detection provides the highest accuracy at all prevalence rates.

  17. HPLC-electrospray mass spectrometric assay for the determination of (R,R)-fenoterol in rat plasma.

    PubMed

    Siluk, Danuta; Kim, Hee Seung; Cole, Tyler; Wainer, Irving W

    2008-11-04

    A fast and specific liquid chromatography-mass spectrometry method for the determination of (R,R)-fenoterol ((R,R)-Fen) in rat plasma has been developed and validated. (R,R)-Fen was extracted from 125 microl of plasma using solid phase extraction and analyzed on Atlantis HILIC Silica 3 microm column. The mobile phase was composed of acetonitrile:ammonium acetate (pH 4.1; 20mM) (85:15, v/v), at a flow rate of 0.2 ml/min. The lower limit of detection (LLOD) was 2 ng/ml . The procedure was validated and applied to the analysis of plasma samples from rats previously administered (R,R)-Fen in an intravenous bolus.

  18. Clinical validation of a highly sensitive assay to detect EGFR mutations in plasma cell-free DNA from patients with advanced lung adenocarcinoma.

    PubMed

    Li, Yuping; Xu, Hanyan; Su, Shanshan; Ye, Junru; Chen, Junjie; Jin, Xuru; Lin, Quan; Zhang, Dongqing; Ye, Caier; Chen, Chengshui

    2017-01-01

    Circulating tumor DNA (ctDNA) is a promising biomarker for noninvasive epidermal growth factor receptor (EGFR) mutations detection in lung cancer patients, but the existing methods have limitations in sensitivity or in availability. In this study, we evaluated the performance of a novel assay called ADx-SuperARMS in detecting EGFR mutations in plasma cell-free DNA from patients with advanced lung adenocarcinoma. A total of 109 patients with metastatic advanced adenocarcinoma were recruited who provided both blood samples and matched tumor tissue samples. EGFR mutation status in plasma samples were tested with ADx-SuperARMS EGFR assay and tumor tissue samples were tested with ADx-ARMS EGFR assay. The clinical sensitivity, specificity, positive prediction value (PPV), and negative prediction value (NPV) of ADx-SuperARMS EGFR assay were calculated by using EGFR mutation status in tumor tissue as standard reference. A receiver operating characteristic (ROC) analysis was implemented and an area under the curve (AUC) was calculated to evaluate sensitivity and specificity of exon 19 deletion (E19Del) and L858R mutation detection. The objective response rate (ORR) were calculated according to the EGFR mutation status determined by ADx-superARMS as well. 0.2% analytical sensitivity and 100% specificity of the ADx-SuperARMS EGFR assays for EGFR E19Del, L858R, and T790M mutants were confirmed by using a series of diluted cell line DNA. In the clinical study, EGFR mutations were detected in 45.9% (50/109) of the plasma samples and in 56.9% (62/109) of the matched tumor tissue samples. The sensitivity, specificity, PPV and NPV of the ADx-SuperARMS EGFR assay for plasma EGFR mutation detection were 82.0% (50/61), 100% (48/48), 100% (50/50), and 81.4% (48/59), respectively. In ROC analysis, ADx-SuperARMS achieved sensitivity and specificity of 88% and 99% in E19Dels as well as sensitivity and specificity of 89% and 100% in L858R, respectively. Among the 35 patients who were plasma EGFR mutation positive and treated with first generation of EGFR-tyrosine kinase inhibitors (TKIs), 23 (65.7%) achieved partial response, 11 (31.4%) sustained disease, and 1 (2.9%) progressive disease. The ORR and disease control rate (DCR) were 65.7% and 97.1%, respectively. ADx-SuperARMS EGFR assay is likely to be a highly sensitive and specific method to noninvasively detect plasma EGFR mutations of patients with advanced lung adenocarcinoma. The EGFR mutations detected by ADx-SuperARMS EGFR assay could predict the efficacy of the treatment with first generation of EGFR-TKIs. Hence, EGFR blood testing with ADx-SuperARMS could address the unmet clinical needs.

  19. [Determination of arsenic speciation in Scomberomorus niphonius by capillary electrophoresis-inductively coupled plasma mass spectrometry].

    PubMed

    Chen, Fa-rong; Zheng, Li; Wang, Zhi-Guang; Sun, Jie; Han, Li-Hui; Wang, Xiao-ru

    2014-06-01

    A method for the detection of arsenocholine (AsC), arsenobetaine (AsB), As(III), dimethylarsinic (DMA), monomethylarsonic (MMA) and As (V) by capillary electrophoresis-inductively coupled plasma mass spectrometry (CE-ICP-MS) was established. The results showed that the six species of arsenic were separated within 20 min under the optimized conditions. Good linearities of 6 arsenic species were observed in the range from 2 to 50 μg x L(-1) with the linear correlation greater than 0.996, the detection limits were 0.10-1.08 μg x L(-1) and the RSDs (n = 5) of the peak areas were smaller than 7%. The method was successfully adopted to the determination of the species in Scomberomorus niphonius. The recoveries were between 93% and 98%, and we found the arsenobetaine (AsB) was the main species in the sample. The method was suitable for the analysis of other biological samples with the advantages of good stability, less sample consumption, short analysis time and convenience.

  20. Tree ring wood analysis after hydrogen peroxide pressure decomposition with inductively coupled plasma atomic emission spectrometry and electrothermal vaporization

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Matusiewicz, H.; Barnes, R.M.

    1985-02-01

    A method utilizing pressure decomposition to minimize sample pretreatment is described for the inductively coupled plasma atomic emission spectrometric analysis of red spruce and sugar maple. Cores collected from trees growing on Camels Hump Mountain, Vermont, were divided into decade increments in order to monitor the temporal changes in concentrations of 21 elements. Dried wood samples were decomposed in a bomb made of Teflon with 50% hydrogen peroxide heated in an oven at 125/sup 0/C for 4 h. The digestion permitted use of aqueous standards and minimized any potential matrix effects. The element concentrations were obtained sequentially by electrothermal vaporizationmore » ICP-AES using 5 ..mu..L sample aliquots. The method precision varied between 3 and 12%. Elements forming oxyanions (Al, As, Fe, Ge, Mn, Si, V) were found at elevated concentrations during the most recent three decades, while other metal (e.g., Mg, Zn) concentrations were unchanged or decreased. 45 references, 6 tables, 1 figure.« less

  1. Comparative study of two protocols for quantitative image-analysis of serotonin transporter clustering in lymphocytes, a putative biomarker of therapeutic efficacy in major depression.

    PubMed

    Romay-Tallon, Raquel; Rivera-Baltanas, Tania; Allen, Josh; Olivares, Jose M; Kalynchuk, Lisa E; Caruncho, Hector J

    2017-01-01

    The pattern of serotonin transporter clustering on the plasma membrane of lymphocytes extracted from human whole blood samples has been identified as a putative biomarker of therapeutic efficacy in major depression. Here we evaluated the possibility of performing a similar analysis using blood smears obtained from rats, and from control human subjects and depression patients. We hypothesized that we could optimize a protocol to make the analysis of serotonin protein clustering in blood smears comparable to the analysis of serotonin protein clustering using isolated lymphocytes. Our data indicate that blood smears require a longer fixation time and longer times of incubation with primary and secondary antibodies. In addition, one needs to optimize the image analysis settings for the analysis of smears. When these steps are followed, the quantitative analysis of both the number and size of serotonin transporter clusters on the plasma membrane of lymphocytes is similar using both blood smears and isolated lymphocytes. The development of this novel protocol will greatly facilitate the collection of appropriate samples by eliminating the necessity and cost of specialized personnel for drawing blood samples, and by being a less invasive procedure. Therefore, this protocol will help us advance the validation of membrane protein clustering in lymphocytes as a biomarker of therapeutic efficacy in major depression, and bring it closer to its clinical application.

  2. Detection of gastric cancer-associated microRNAs on microRNA microarray comparing pre- and post-operative plasma

    PubMed Central

    Konishi, H; Ichikawa, D; Komatsu, S; Shiozaki, A; Tsujiura, M; Takeshita, H; Morimura, R; Nagata, H; Arita, T; Kawaguchi, T; Hirashima, S; Fujiwara, H; Okamoto, K; Otsuji, E

    2012-01-01

    Background: Recently, it was reported that plasma microRNAs (miRNAs) are low-invasive useful biomarkers for cancer. We attempted to isolate gastric cancer (GC)-associated miRNAs comparing pre- and post-operative paired plasma, thereby excluding the possible effects of individual variability. Methods: This study was divided into four steps: (1) microarray analysis comparing pre- and post-operative plasma; (2) validation of candidate miRNAs by quantitative RT–PCR; (3) validation study of selected miRNAs using paired plasma; and (4) comparison of the levels of selected miRNAs in plasma between healthy controls and patients. Results: From the results of microarray analysis, nine candidate miRNAs the levels of which were markedly decreased in post-operative plasma were selected for further studies. After confirmation of their post-operative marked reduction, two candidate miRNAs, miR-451 and miR-486, were selected as plasma biomarkers, considering the abundance in plasma, and marked decrease in post-operative samples. In validation, the two miRNAs were found to decrease in post-operative plasma in 90 and 93% of patients (both P<0.01). In comparison with healthy controls, the levels of both miRNAs were found to be significantly higher in patients, and the area under the curve values were high at 0.96 and 0.92. Conclusion: Plasma miR-451 and miR-486 could be useful blood-based biomarkers for screening GC. PMID:22262318

  3. High Resolution Mass Spectrometric Analysis of Secoiridoids and Metabolites as Biomarkers of Acute Olive Oil Intake-An Approach to Study Interindividual Variability in Humans.

    PubMed

    Silva, Sandra; Garcia-Aloy, Mar; Figueira, Maria Eduardo; Combet, Emilie; Mullen, William; Bronze, Maria Rosário

    2018-01-01

    Phenolic compounds are minor components of extra virgin olive oil (EVOO). Secoiridoids are the major components contributing to the phenolic content of EVOO. Information is lacking regarding their potential as biomarkers for EVOO intake. Healthy volunteers (n = 9) ingested 50 mL of EVOO in a single dose containing 322 mg kg -1 total phenolic content (caffeic acid equivalents) and 6 mg 20 g -1 hydroxytyrosol and its derivatives. Plasma is collected before (0 h) and at 0.5, 1, 2, 4, and 6 h after ingestion. Urine samples are collected prior to ingestion (0 h) and at 0-4, 4-8, 8-15, and 15-24 h. Samples are analyzed by UPLC coupled with an Exactive Orbitrap MS. Partial least squares discriminant analysis with orthogonal signal correction is applied to screen for metabolites that allow sample discrimination. Plasma biomarkers and urine biomarkers are selected although individual variability is observed among volunteers. Results are in accordance with in vitro experiments performed (in vitro digestion and hepatic microsomal activity assays). Plasma (elenolic acid + H 2 ; p-HPEA-EA + H 2 + glucuronide) and urinary (3,4-DHPEA-EA, 3,4-DHPEA-EA + H 2 +glucuronide, methyl 3,4-DHPEA-EA + H 2 +glucuronide) secoiridoid compounds are selected as biomarkers to monitor EVOO intake showing good predictive ability according to multivariate analysis. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. Multi-component immunoaffinity subtraction chromatography: an innovative step towards a comprehensive survey of the human plasma proteome.

    PubMed

    Pieper, Rembert; Su, Qin; Gatlin, Christine L; Huang, Shih-Ting; Anderson, N Leigh; Steiner, Sandra

    2003-04-01

    In order to discover novel protein markers indicative of disease processes or drug effects, the proteomics technology platform most commonly used consists of high resolution protein separation by two-dimensional electrophoresis (2-DE), mass spectrometric identification of proteins from stained gel spots and a bioinformatic data analysis process supported by statistics. This approach has been more successful in profiling proteins and their disease- or treatment-related quantitative changes in tissue homogenates than in plasma samples. Plasma protein display and quantitation suffer from several disadvantages: very high abundance of a few proteins; high heterogeneity of many proteins resulting in long charge trains; crowding of 2-DE separated protein spots in the molecular mass range between 45-80 kD and in the isoelectric point range between 4.5 and 6. Therefore, proteomic technologies are needed that address these problems and particularly allow accurate quantitation of a larger number of less abundant proteins in plasma and other body fluids. The immunoaffinity-based protein subtraction chromatography (IASC) described here removes multiple proteins present in plasma and serum in high concentrations effectively and reproducibly. Applying IASC as an upfront plasma sample preparation process for 2-DE, the protein spot pattern observed in gels changes dramatically and at least 350 additional lower abundance proteins are visualized. Affinity-purified polyclonal antibodies (pAbs) are the immunoaffinity reagents used to specifically remove the abundant proteins such as albumin, immunoglobulin G, immunoglobulin A, transferrin, haptoglobin, alpha-1-antitrypsin, hemopexin, transthyretin, alpha-2-HS glycoprotein, alpha-1-acid glycoprotein, alpha-2-macroglobulin and fibrinogen from human plasma samples. To render the immunoaffinity subtraction procedure recyclable, the pAbs are immobilized and cross-linked on chromatographic matrices. Antibody-coupled matrices specific for one protein each can be pooled to form mixed-bed IASC columns. We show that up to ten affinity-bound plasma proteins with similar solubility characteristics are eluted from a mixed-bed column in one step. This facilitates automated chromatographic processing of plasma samples in high throughput, which is desirable in proteomic disease marker discovery projects.

  5. Experiment requirements: Vitamin D metabolites and bone demineralization, Spacelab 2, experiment no. 1

    NASA Technical Reports Server (NTRS)

    Schnoes, H. K.; Holton, E. M.; Thirolf, R. G.

    1978-01-01

    As a contribution toward an understanding of the molecular basis of bone loss, mineral imbalance, and increasing fecal calcium under conditions of prolonged space flight, the blood levels of biologically active vitamin D metabolites of flight crew members will be quantitatively measured. Prior to the mission, the refinement of existing and the development of new techniques for the assay of all vitamin D metabolites will provide an arsenal of methods suitable for a wide range of metabolite levels. In terms of practical application, the analysis of human and animal plasma samples, Spacelab crew plasma samples, and flight hardware are envisioned.

  6. Surface modification of gutta-percha cones by non-thermal plasma.

    PubMed

    Prado, Maíra; Menezes, Marilia Santana de Oliveira; Gomes, Brenda Paula Figueiredo de Almeida; Barbosa, Carlos Augusto de Melo; Athias, Leonardo; Simão, Renata Antoun

    2016-11-01

    This study was designed to evaluate the effects of Oxygen and Argon plasma on gutta-percha surfaces. A total of 185 flat smooth gutta-percha surfaces were used. Samples were divided into groups: control: no plasma treatment; Oxygen: treatment with Oxygen plasma for 1min; Argon: treatment with Argon plasma for 1min. Samples were evaluated topographically by scanning electron microscopy and atomic force microscopy; and chemically by Fourier Transform-infrared Spectroscopy. A goniometer was used to determine the surface free energy and the wettability of the endodontic sealers. Additionally 60 bovine teeth were filled using pellets of gutta-percha (control, oxygen and argon plasma) and the sealers. Teeth were evaluated by push-out and microleakage tests. Data were statistically analyzed using specific tests. Argon plasma did not change the surface topography, while Oxygen plasma led to changes. Both treatments chemically modified the gutta-percha surface. Argon and Oxygen plasma increased the surface free energy and favored the wettability of AH Plus and Pulp Canal Sealer EWT. Regarding bond strength analysis, for AH Plus sealer, both plasma treatments on gutta-percha favored the bond strength to dentin. However, for Pulp Canal Sealer, there is no statistically significant influence. For leakage test, dye penetration occurred between sealer and dentin in all groups. In conclusion, Oxygen plasma led to both topographic and chemical changes in the gutta-percha surface, while Argon plasma caused only chemical changes. Both treatments increased the surface free energy, favoring the wettability of AH Plus and Pulp Canal Sealer EWT sealers and influenced positively in the adhesion and leakage. Copyright © 2016 Elsevier B.V. All rights reserved.

  7. Sterilization of Turmeric by Atmospheric Pressure Dielectric Barrier Discharge Plasma

    NASA Astrophysics Data System (ADS)

    Setareh, Salarieh; Davoud, Dorranian

    2013-11-01

    In this study atmospheric pressure dielectric barrier discharge (DBD) plasma has been employed for sterilizing dry turmeric powders. A 6 kV, 6 kHz frequency generator was used to generate plasma with Ar, Ar/O2, He, and He/O2 gases between the 5 mm gap of two quartz covered electrodes. The complete sterilization time of samples due to plasma treatment was measured. The most important contaminant of turmeric is bacillus subtilis. The results show that the shortest sterilization time of 15 min is achieved by exposing the samples to Ar/O2 plasma. Survival curves of samples are exponential functions of time and the addition of oxygen to plasma leads to a significant increase of the absolute value of time constant of the curves. Magnitudes of protein and DNA in treated samples were increased to a similar value for all samples. Taste, color, and solubility of samples were not changed after the plasma treatment.

  8. Contribution of bulk mass spectrometry isotopic analysis to characterization of materials in the framework of CMX-4

    DOE PAGES

    Kuchkin, A.; Stebelkov, V.; Zhizhin, K.; ...

    2018-01-30

    Seven laboratories used the results of bulk uranium isotopic analysis by either inductively coupled plasma mass spectrometry (ICP-MS) or thermal ionization mass spectrometry (TIMS) for characterization of the samples in the Nuclear Forensic International Technical Working Group fourth international collaborative material exercise, CMX-4. Comparison of the measured isotopic compositions of uranium in three exercise samples is implemented for identifying any differences or similarities between the samples. The role of isotopic analyses in the context of a real nuclear forensic investigation is discussed. Several limitations in carrying out ICP-MS or TIMS analysis in CMX-4 are noted.

  9. Contribution of bulk mass spectrometry isotopic analysis to characterization of materials in the framework of CMX-4

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kuchkin, A.; Stebelkov, V.; Zhizhin, K.

    Seven laboratories used the results of bulk uranium isotopic analysis by either inductively coupled plasma mass spectrometry (ICP-MS) or thermal ionization mass spectrometry (TIMS) for characterization of the samples in the Nuclear Forensic International Technical Working Group fourth international collaborative material exercise, CMX-4. Comparison of the measured isotopic compositions of uranium in three exercise samples is implemented for identifying any differences or similarities between the samples. The role of isotopic analyses in the context of a real nuclear forensic investigation is discussed. Several limitations in carrying out ICP-MS or TIMS analysis in CMX-4 are noted.

  10. Direct targeting of human plasma for matrix-assisted laser desorption/ionization and analysis of plasma proteins by time of flight-mass spectrometry.

    PubMed

    Jin, Ya; Manabe, Takashi

    2005-07-01

    A method to analyze human plasma proteins without fractionation, directly applying a plasma-matrix mixture on the target plate of a matrix-assisted laser desorption/ionization-time of flight-mass spectrometer (MALDI-TOF-MS), has been described. Peaks of ionized plasma proteins could not be detected applying a mixture of an undiluted plasma sample and a matrix solution, but they appeared when the plasma was diluted before mixing with the matrix. Tenfold diluted plasma provided well-resolved protein peaks in the m/z range from 4000 to 30,000. The addition of a simple post-crystallization washing procedure performed on the target plate further improved the quality of mass spectra. We numbered 58 peaks in the range of 4-160 kDa and 32 out of which were assigned to the plasma protein species which have been reported. Especially high sensitivity and resolution were obtained in the region < 30 kDa, where multiple isoforms of apolipoprotein A-I, apolipoprotein A-II, apolipoprotein C-I, apolipoprotein C-II, apolipoprotein C-III, and transthyretin could be assigned. Various post-translational modifications are involved in the isoforms, e.g., proteolytic cleavage, glycosylation and chemical modifications. This method will become complementary with the present electrophoretic techniques, especially for the analysis of low-molecular-mass proteins.

  11. Association between the miRNA Signatures in Plasma and Bronchoalveolar Fluid in Respiratory Pathologies

    PubMed Central

    Molina-Pinelo, Sonia; Suárez, Rocío; Pastor, María Dolores; Nogal, Ana; Márquez-Martín, Eduardo; Martín-Juan, José; Carnero, Amancio; Paz-Ares, Luis

    2012-01-01

    The identification of new less invasive biomarkers is necessary to improve the detection and prognostic outcome of respiratory pathological processes. The measurement of miRNA expression through less invasive techniques such as plasma and serum have been suggested to analysis of several lung malignancies including lung cancer. These studies are assuming a common deregulated miRNA expression both in blood and lung tissue. The present study aimed to obtain miRNA representative signatures both in plasma and bronchoalveolar cell fraction that could serve as biomarker in respiratory diseases. Ten patients were evaluated to assess the expression levels of 381 miRNAs. We found that around 50% miRNAs were no detected in both plasma and bronchoalveolar cell fraction and only 20% of miRNAs showed similar expression in both samples. These results show a lack of association of miRNA signatures between plasma and bronchoalveolar cytology in the same patient. The profiles are not comparable; however, there is a similarity in the relative expression in a very small subset of miRNAs (miR-17, miR-19b, miR-195 and miR-20b) between both biological samples in all patients. This finding supports that the miRNAs profiles obtained from different biological samples have to be carefully validated to link with respiratory diseases. PMID:22430188

  12. Novel stereoselective high-performance liquid chromatographic method for simultaneous determination of guaifenesin and ketorolac enantiomers in human plasma.

    PubMed

    Maher, Hadir M; Al-Taweel, Shorog M; Alshehri, Mona M; Alzoman, Nourah Z

    2014-10-01

    A novel method was developed for the simultaneous determination of guaifenesin (GUA) and ketorolac tromethamine (KET) enantiomers in plasma samples. Since GUA probably increases the absorption of coadministered drugs (e.g., KET), it would be extremely important to monitor KET plasma levels for the purpose of dose adjustment with a subsequent decrease in the side effects. Enantiomeric resolution was achieved on a polysaccharide-based chiral stationary phase, amylose-2, as a chiral selector under the normal phase (NP) mode and using ornidazole (ORN) as internal standard. This innovative method has the advantage of the ease and reliability of sample preparation for plasma samples. Sample clean-up was based on simply using methanol for protein precipitation followed by direct extraction of drug residues using ethanol. Both GUA and KET enantiomers were separated using an isocratic mobile phase composed of hexane/isopropanol/trifluoroacetic acid, 85:15:0.05 v/v/v. Peak area ratios were linear over the range 0.05-20 µg/mL for the four enantiomers S (+) GUA, R (-) GUA, R (+) KET, and S (-) KET. The method was fully validated according to the International Conference on Harmonization (ICH) guidelines in terms of system suitability, specificity, accuracy, precision, robustness, and solution stability. Finally, this procedure was innovative to apply the rationale of developing a chiral high-performance liquid chromatography (HPLC) procedure for the simultaneous quantitative analysis of drug isomers in clinical samples. © 2014 Wiley Periodicals, Inc.

  13. IMPROVED DERIVATION OF INPUT FUNCTION IN DYNAMIC MOUSE [18F]FDG PET USING BLADDER RADIOACTIVITY KINETICS

    PubMed Central

    Wong, Koon-Pong; Zhang, Xiaoli; Huang, Sung-Cheng

    2013-01-01

    Purpose Accurate determination of the plasma input function (IF) is essential for absolute quantification of physiological parameters in positron emission tomography (PET). However, it requires an invasive and tedious procedure of arterial blood sampling that is challenging in mice because of the limited blood volume. In this study, a hybrid modeling approach is proposed to estimate the plasma IF of 2-deoxy-2-[18F]fluoro-D-glucose ([18F]FDG) in mice using accumulated radioactivity in urinary bladder together with a single late-time blood sample measurement. Methods Dynamic PET scans were performed on nine isoflurane-anesthetized male C57BL/6 mice after a bolus injection of [18F]FDG at the lateral caudal vein. During a 60- or 90-min scan, serial blood samples were taken from the femoral artery. Image data were reconstructed using filtered backprojection with CT-based attenuation correction. Total accumulated radioactivity in the urinary bladder was fitted to a renal compartmental model with the last blood sample and a 1-exponential function that described the [18F]FDG clearance in blood. Multiple late-time blood sample estimates were calculated by the blood [18F]FDG clearance equation. A sum of 4-exponentials was assumed for the plasma IF that served as a forcing function to all tissues. The estimated plasma IF was obtained by simultaneously fitting the [18F]FDG model to the time-activity curves (TACs) of liver and muscle and the forcing function to early (0–1 min) left-ventricle data (corrected for delay, dispersion, partial-volume effects and erythrocytes uptake) and the late-time blood estimates. Using only the blood sample acquired at the end of the study to estimate the IF and the use of liver TAC as an alternative IF were also investigated. Results The area under the plasma TACs calculated for all studies using the hybrid approach was not significantly different from that using all blood samples. [18F]FDG uptake constants in brain, myocardium, skeletal muscle and liver computed by the Patlak analysis using estimated and measured plasma TACs were in excellent agreement (slope ~ 1; R2 > 0.938). The IF estimated using only the last blood sample acquired at the end of the study and the use of liver TAC as plasma IF provided less reliable results. Conclusions The estimated plasma IFs obtained with the hybrid model agreed well with those derived from arterial blood sampling. Importantly, the proposed method obviates the need of arterial catheterization, making it possible to perform repeated dynamic [18F]FDG PET studies on the same animal. Liver TAC is unsuitable as an input function for absolute quantification of [18F]FDG PET data. PMID:23322346

  14. A comparative study of thermochemical and cold plasma treatment on lignin-based activated carbon for adsorbing Fe(III)

    NASA Astrophysics Data System (ADS)

    Shi, Shukai; Wang, Xin; Chen, Weimin; Chen, Minzhi; Zhou, Xiaoyan

    2018-05-01

    The as-prepared lignin-based activated carbon (LAC) was post-treated by urea and radio-frequency cold plasma separately. The obtained results demonstrated that the BET surface and total volumes of the LAC and plasma-treated LACs were greater than the urea-modified sample. The analysis of surface elemental composition showed that the nitrogen content of urea-modified LAC and nitrogen plasma-treated LAC are 3.79% and 2.62% higher than that of original LAC respectively, while the oxygen content of air plasma-treated LAC is 10.23% higher than that of original LAC. The Fe(III) ions adsorbed studies with pseudo-second order kinetic model revealed that urea-modified LAC had faster chemisorption rates while air plasma-treated LAC had larger adsorption capacity within 3 h. Moreover, the adsorption capacity and chemisorption rates of LAC post-treated by nitrogen plasma are inferior to the air plasma-treated LAC.

  15. Effects in vivo of iohexol and diatrizoate on human plasma acetyl- and butyryl-cholinesterase activity.

    PubMed

    Mironidou, M; Katsimba, D; Kokkas, B; Kaitartzis, C; Karamanos, G; Christopoulos, S

    2001-03-01

    The aim of this study was to evaluate the effects of two iodinate contrast agents (CA), iohexol and diatrizoate, on human plasma acetyl-(AC) and butyrylcholinesterase(BC) activity. Forty-eight patients (24 males and 24 females) scheduled for intravenous pyelography were randomly divided into four groups of 6 males and 6 females each, receiving as CA, respectively: iohexol (Omnipaque, Schering) 0.6 ml/kg body weight (G1); iohexol 1.2 mg/kg (G2); sodium and meglumine diatrizoate 58% (Urografin, Schering) 0.6 ml/kg (G3); sodium and meglumine diatrizoate 58% 1.2 ml/kg (G4). Blood samples were taken before and 5, 10, and 20 min after the injection. Enzymatic activity of AC and BC were measured by spectrophotometry. Plasma concentration of K, Na, Ca, and Mg was measured in all blood samples; blood pressure and plasma pH were measured after each sample collection. Statistical analysis was performed by Student's test. In G1 a reversible decrease of AC (12.9%) and BC (8.2%) plasma activity was observed at 10 min. In G2 a progressive decrease of AC (13.9%) and BC (18.4%) plasma activity was observed with a maximum at 20 min. In G3 a modest reversible decrease of BC plasma activity (5.4%) was observed. In G4 a modest progressive decrease of AC (7.3%) and BC (6.5%) plasma activities was observed. In all cases, AC and BC plasma activities remained within the normal range of values. Plasma concentration of K, Na, Ca, and Mg, as well as pH and systolic and diastolic pressure, did not show any change. No adverse effects was observed in our patients. Iohexol and diatrizoate induce in vivo a significant decrease of AC and BC plasma activities. The decrease is more pronounced for iohexol, a non ionic CA, which has a lower pharmacotoxicity than diatrizoate and adverse effects rate. No inference can be drawn about the relationship between plasma cholinesterase activity and adverse effects.

  16. Clinical validation of an ultra high-throughput spiral microfluidics for the detection and enrichment of viable circulating tumor cells.

    PubMed

    Khoo, Bee Luan; Warkiani, Majid Ebrahimi; Tan, Daniel Shao-Weng; Bhagat, Ali Asgar S; Irwin, Darryl; Lau, Dawn Pingxi; Lim, Alvin S T; Lim, Kiat Hon; Krisna, Sai Sakktee; Lim, Wan-Teck; Yap, Yoon Sim; Lee, Soo Chin; Soo, Ross A; Han, Jongyoon; Lim, Chwee Teck

    2014-01-01

    Circulating tumor cells (CTCs) are cancer cells that can be isolated via liquid biopsy from blood and can be phenotypically and genetically characterized to provide critical information for guiding cancer treatment. Current analysis of CTCs is hindered by the throughput, selectivity and specificity of devices or assays used in CTC detection and isolation. Here, we enriched and characterized putative CTCs from blood samples of patients with both advanced stage metastatic breast and lung cancers using a novel multiplexed spiral microfluidic chip. This system detected putative CTCs under high sensitivity (100%, n = 56) (Breast cancer samples: 12-1275 CTCs/ml; Lung cancer samples: 10-1535 CTCs/ml) rapidly from clinically relevant blood volumes (7.5 ml under 5 min). Blood samples were completely separated into plasma, CTCs and PBMCs components and each fraction were characterized with immunophenotyping (Pan-cytokeratin/CD45, CD44/CD24, EpCAM), fluorescence in-situ hybridization (FISH) (EML4-ALK) or targeted somatic mutation analysis. We used an ultra-sensitive mass spectrometry based system to highlight the presence of an EGFR-activating mutation in both isolated CTCs and plasma cell-free DNA (cf-DNA), and demonstrate concordance with the original tumor-biopsy samples. We have clinically validated our multiplexed microfluidic chip for the ultra high-throughput, low-cost and label-free enrichment of CTCs. Retrieved cells were unlabeled and viable, enabling potential propagation and real-time downstream analysis using next generation sequencing (NGS) or proteomic analysis.

  17. Quantitative Method for Analysis of Hydrocodone, Hydromorphone and Norhydrocodone in Human Plasma by Liquid Chromatography-tandem Mass Spectrometry

    DTIC Science & Technology

    2013-03-01

    ratio ranges obtained for the six standards. Twelve samples were analyzed to demonstrate the efficiency of the extraction procedure. Drug and internal...frozen (−70 ◦C). Refrigerated samples were tested after 2 months of storage ; frozen samples were tested for up to 1 year from stor- age date. The...freeze–thaw stability was evaluated by analyzing three subject samples with known drug concentrations and two quality control samples at concentrations

  18. Identification of metal elements by time-resolved LIBS technique in sediments lake the “Cisne”

    NASA Astrophysics Data System (ADS)

    Pacheco, P.; Arregui, E.; Álvarez, J.; Rangel, N.; Sarmiento, R.

    2017-01-01

    Laser induced breakdown spectroscopy (LIBS), is a kind of spectral method of atomic emission that uses pulses of radiation high energy laser as excitation source. One of the advantages of technical LIBS lies in the possibility of analyse the substances in any State of aggregation, already is solid, liquid or gaseous, even in colloids as aerosols, gels and others. Another advantage over other conventional techniques is the simultaneous analysis of elements present in a sample of multielement. This work is made in the use of this technique for the identification of metal pollutants in the Swan Lake sediment samples, collected by drilling cores. Plasmas were generated by focusing the radiation of Nd: YAG laser with an energy per pulse 13mJ and 4ns duration, wavelength of 532nm. The spectra of radiation from the plasmas of sediment were recorded with an Echelle spectrograph type coupled to an ICCD camera. The delay times were between 0.5μs and 7μs, while the gate width was of 2μs. To ensure the homogeneity of the plasmas, the sediment sample was placed in a positioning system of linear and rotary adjustment of smooth step synchronized with the trigger of the laser pulse. The registration of the spectra of the sediment to different times of delay, allowed to identify the lines prominent of the different elements present in the sample. The analysis of the Spectra allowed the identification of some elements in the sample as if, Ca, Na, Mg, and Al through the measurement of wavelengths of the prominent peaks.

  19. Smoothed Particle Inference Analysis of SNR RCW 103

    NASA Astrophysics Data System (ADS)

    Frank, Kari A.; Burrows, David N.; Dwarkadas, Vikram

    2016-04-01

    We present preliminary results of applying a novel analysis method, Smoothed Particle Inference (SPI), to an XMM-Newton observation of SNR RCW 103. SPI is a Bayesian modeling process that fits a population of gas blobs ("smoothed particles") such that their superposed emission reproduces the observed spatial and spectral distribution of photons. Emission-weighted distributions of plasma properties, such as abundances and temperatures, are then extracted from the properties of the individual blobs. This technique has important advantages over analysis techniques which implicitly assume that remnants are two-dimensional objects in which each line of sight encompasses a single plasma. By contrast, SPI allows superposition of as many blobs of plasma as are needed to match the spectrum observed in each direction, without the need to bin the data spatially. This RCW 103 analysis is part of a pilot study for the larger SPIES (Smoothed Particle Inference Exploration of SNRs) project, in which SPI will be applied to a sample of 12 bright SNRs.

  20. U.S.-MEXICO BORDER PROGRAM ARIZONA BORDER STUDY--STANDARD OPERATING PROCEDURE FOR EXTRACTION OF METALS FROM SOIL, DUST, AIR FILTER, AND SURFACE AND DERMAL WIPE SAMPLES FOR AA (GRAPHITE FURNACE OR FLAME) OR ICP-AES ANALYSIS (BCO-L-3.1)

    EPA Science Inventory

    The purpose of this SOP is to describe the acid digestion of soil, house dust, air filter, and surface or dermal wipe samples for analysis using inductively coupled plasma atomic emissions spectrometry (ICP-AES) and/or graphite furnace atomic absorption spectrometry (GFAAS) or fl...

  1. Moessbauer spectroscopy study on the corrosion resistance of plasma nitrided ASTM F138 stainless steel in chloride solution

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Souza, S.D. de; Olzon-Dionysio, M., E-mail: dmod@df.ufscar.br; Basso, R.L.O.

    2010-10-15

    Plasma nitriding of ASTM F138 stainless steel samples has been carried out using dc glow discharge under 80% H{sub 2}-20% N{sub 2} gas mixture, at 673 K, and 2, 4, and 7 h time intervals, in order to investigate the influence of treatment time on the microstructure and the corrosion resistance properties. The samples were characterized by scanning electron microscopy, glancing angle X-ray diffraction and conversion electron Moessbauer spectroscopy, besides electrochemical tests in NaCl aerated solution. A modified layer of about 6 {mu}m was observed for all the nitrided samples, independent of nitriding time. The X-ray diffraction analysis shows broadmore » {gamma}{sub N} phase peaks, signifying a great degree of nitrogen supersaturation. Besides {gamma}{sub N,} the Moessbauer spectroscopy results indicated the occurrence of {gamma}' and {epsilon} phases, as well as some other less important phases. Corrosion measurements demonstrate that the plasma nitriding time affects the corrosion resistance and the best performance is reached at 4 h treatment. It seems that the {epsilon}/{gamma}' fraction ratio plays an important role on the resistance corrosion. Additionally, the Moessbauer spectroscopy was decisive in this study, since it was able to identify and quantify the iron phases that influence the corrosion resistance of plasma nitrided ASTM F138 samples.« less

  2. Motion of W and He atoms during formation of W fuzz

    NASA Astrophysics Data System (ADS)

    Doerner, R. P.; Nishijima, D.; Krasheninnikov, S. I.; Schwarz-Selinger, T.; Zach, M.

    2018-06-01

    Measurements are conducted to identify the motion of tungsten and helium atoms during the formation of tungsten fuzz. In a first series of experiments the mobility of helium within the growing fuzz was measured by adding 3He to the different stages of plasma exposure under conditions that promoted tungsten fuzz growth. Ion beam analysis was used to quantify the amount of 3He remaining in the samples following the plasma exposure. The results indicate that the retention of helium in bubbles within tungsten is a dynamic process with direct implantation rather than diffusion into the bubbles, best describing the motion of the helium atoms. In the second experiment, an isotopically enriched layer of tungsten (~92.99% 182W) is deposited on the surface of a bulk tungsten sample with the natural abundance of the isotopes. This sample is then exposed to helium plasma at the conditions necessary to support the formation of tungsten ‘fuzz’. Depth profiles of the concentration of each of the tungsten isotopes are obtained using secondary ion mass spectrometry (SIMS) before and after the plasma exposure. The depth profiles clearly show mixing of tungsten atoms from the bulk sample toward the surface of the fuzz. This supports a physical picture of the dynamic behavior of helium bubbles which, also, causes an enhanced mixing of tungsten atoms.

  3. Motion of W and He atoms during formation of W fuzz

    DOE PAGES

    Doerner, R. P.; Nishijima, D.; Krasheninnikov, S. I.; ...

    2018-04-11

    Measurements are conducted to identify the motion of tungsten and helium atoms during the formation of tungsten fuzz. In a first series of experiments the mobility of helium within the growing fuzz was measured by adding 3He to the different stages of plasma exposure under conditions that promoted tungsten fuzz growth. Ion beam analysis was used to quantify the amount of 3He remaining in the samples following the plasma exposure. The results indicate that the retention of helium in bubbles within tungsten is a dynamic process with direct implantation rather than diffusion into the bubbles, best describing the motion ofmore » the helium atoms. In the second experiment, an isotopically enriched layer of tungsten (~92.99% 182W) is deposited on the surface of a bulk tungsten sample with the natural abundance of the isotopes. This sample is then exposed to helium plasma at the conditions necessary to support the formation of tungsten 'fuzz'. Depth profiles of the concentration of each of the tungsten isotopes are obtained using secondary ion mass spectrometry (SIMS) before and after the plasma exposure. The depth profiles clearly show mixing of tungsten atoms from the bulk sample toward the surface of the fuzz. Lastly, this supports a physical picture of the dynamic behavior of helium bubbles which, also, causes an enhanced mixing of tungsten atoms.« less

  4. Measurement and analysis of x-ray absorption in Al and MgF2 plasmas heated by Z-pinch radiation.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    MacFarlane, Joseph John; Rochau, Gregory Alan; Bailey, James E.

    2005-06-01

    High-power Z pinches on Sandia National Laboratories Z facility can be used in a variety of experiments to radiatively heat samples placed some distance away from the Z-pinch plasma. In such experiments, the heating radiation spectrum is influenced by both the Z-pinch emission and the re-emission of radiation from the high-Z surfaces that make up the Z-pinch diode. To test the understanding of the amplitude and spectral distribution of the heating radiation, thin foils containing both Al and MgF{sub 2} were heated by a 100-130 TW Z pinch. The heating of these samples was studied through the ionization distribution inmore » each material as measured by x-ray absorption spectra. The resulting plasma conditions are inferred from a least-squares comparison between the measured spectra and calculations of the Al and Mg 1s {yields} 2p absorption over a large range of temperatures and densities. These plasma conditions are then compared to radiation-hydrodynamics simulations of the sample dynamics and are found to agree within 1{sigma} to the best-fit conditions. This agreement indicates that both the driving radiation spectrum and the heating of the Al and MgF{sub 2} samples is understood within the accuracy of the spectroscopic method.« less

  5. Determination of urea kinetics by isotope dilution with [13C]urea and gas chromatography-isotope ratio mass spectrometry (GC-IRMS) analysis.

    PubMed

    Kloppenburg, W D; Wolthers, B G; Stellaard, F; Elzinga, H; Tepper, T; de Jong, P E; Huisman, R M

    1997-07-01

    1. Stable urea isotopes can be used to study urea kinetics in humans. The use of stable urea isotopes for studying urea kinetic parameters in humans on a large scale is hampered by the high costs of the labelled material. We devised a urea dilution for measurement of the distribution volume, production rate and clearance of urea in healthy subjects and renal failure patients using the inexpensive single labelled [13C]urea isotope with subsequent analysis by headspace chromatography-isotope ratio MS (GC-IRMS) of the [13C]urea enrichment. 2. The method involves measurement of the molar percentage excess of [13C]urea in plasma samples taken over a 4 h period after an intravenous bolus injection of [13C]urea. During the sample processing procedure, the plasma samples together with calibration samples containing a known molar percentage excess of [13C]urea are acidified with phosphoric acid to remove endogenous CO2, and are subsequently incubated with urease to convert the urea present in the plasma samples into CO2. The 13C enrichment of the generated CO2 is analysed by means of GC-IRMS. This method allows measurement of the molar percentage excess of [13C]urea to an accuracy of 0.02%. 3. Reproducibility studies showed that the sample processing procedure [within-run coefficient of variation (CV) < 2.8% and between-run CV < 8.8%] and the GC-IRMS analysis (within-day CV < 1.3% and between-day CV < 1.3%) could be repeated with good reproducibility. 4. In clinical urea kinetic studies in a healthy subject and in a renal failure patient without residual renal function, reproducible values of the distribution volume, production rate and clearance of urea were determined using minimal amounts of [13C]urea (25-50 mg). 5. Because only low [13C]urea enrichments are needed in this urea dilution method using GC-IRMS analysis, the costs of urea kinetic studies are reduced considerably, especially in patients with renal failure.

  6. Method development aspects for the quantitation of pharmaceutical compounds in human plasma with a matrix-assisted laser desorption/ionization source in the multiple reaction monitoring mode.

    PubMed

    Kovarik, Peter; Grivet, Chantal; Bourgogne, Emmanuel; Hopfgartner, Gérard

    2007-01-01

    The present work investigates various method development aspects for the quantitative analysis of pharmaceutical compounds in human plasma using matrix-assisted laser desorption/ionization and multiple reaction monitoring (MALDI-MRM). Talinolol was selected as a model analyte. Liquid-liquid extraction (LLE) and protein precipitation were evaluated regarding sensitivity and throughput for the MALDI-MRM technique and its applicability without and with chromatographic separation. Compared to classical electrospray liquid chromatography/mass spectrometry (LC/ESI-MS) method development, with MALDI-MRM the tuning of the analyte in single MS mode is more challenging due to interfering matrix background ions. An approach is proposed using background subtraction. With LLE and using a 200 microL human plasma aliquot acceptable precision and accuracy could be obtained in the range of 1 to 1000 ng/mL without any LC separation. Approximately 3 s were required for one analysis. A full calibration curve and its quality control samples (20 samples) can be analyzed within 1 min. Combining LC with the MALDI analysis allowed improving the linearity down to 50 pg/mL, while reducing the throughput potential only by two-fold. Matrix effects are still a significant issue with MALDI but can be monitored in a similar way to that used for LC/ESI-MS analysis.

  7. Assays of plasma dehydrocholesteryl esters and oxysterols from Smith-Lemli-Opitz syndrome patients[S

    PubMed Central

    Liu, Wei; Xu, Libin; Lamberson, Connor R.; Merkens, Louise S.; Steiner, Robert D.; Elias, Ellen R.; Haas, Dorothea; Porter, Ned A.

    2013-01-01

    Smith-Lemli-Opitz syndrome (SLOS) is caused by mutations in the gene encoding 3β-hydroxysterol-Δ7-reductase and as a result of this defect, 7-dehydrocholesterol (7-DHC) and 8-dehydrocholesterol (8-DHC) accumulate in the fluids and tissues of patients with this syndrome. Both 7- and 8-DHC are susceptible to peroxidation reactions, and several biologically active DHC oxysterols are found in cell and animal models of SLOS. Ex vivo oxidation of DHCs can be a confounding factor in the analysis of these sterols and their esters, and we developed HPLC/MS methods that permit the direct analysis of cholesterol, 7-DHC, 8-DHC, and their esters in human plasma, thus avoiding ex vivo oxidation. In addition, three oxysterols were classified as endogenously formed products by the use of an isotopically-labeled 7-DHC (d7-7-DHC) added to the sample before workup, followed by MS analysis of products formed. Analysis of 17 SLOS plasma samples shows that 8-DHC linoleate correlates better with the SLOS severity score of the patients than other sterols or metabolites, including cholesterol and 7-DHC. Levels of 7-ketocholesterol also correlate with the SLOS severity score. 8-DHC esters should have utility as surrogate markers of severity in SLOS for prognostication and as endpoints in clinical trials. PMID:23072947

  8. Handling and storage of human body fluids for analysis of extracellular vesicles

    PubMed Central

    Yuana, Yuana; Böing, Anita N.; Grootemaat, Anita E.; van der Pol, Edwin; Hau, Chi M.; Cizmar, Petr; Buhr, Egbert; Sturk, Auguste; Nieuwland, Rienk

    2015-01-01

    Because procedures of handling and storage of body fluids affect numbers and composition of extracellular vesicles (EVs), standardization is important to ensure reliable and comparable measurements of EVs in a clinical environment. We aimed to develop standard protocols for handling and storage of human body fluids for EV analysis. Conditions such as centrifugation, single freeze–thaw cycle, effect of time delay between blood collection and plasma preparation and storage were investigated. Plasma is the most commonly studied body fluid in EV research. We mainly focused on EVs originating from platelets and erythrocytes and investigated the behaviour of these 2 types of EVs independently as well as in plasma samples of healthy subjects. EVs in urine and saliva were also studied for comparison. All samples were analysed simultaneously before and after freeze–thawing by resistive pulse sensing, nanoparticle tracking analysis, conventional flow cytometry (FCM) and transmission (scanning) electron microscopy. Our main finding is that the effect of centrifugation markedly depends on the cellular origin of EVs. Whereas erythrocyte EVs remain present as single EVs after centrifugation, platelet EVs form aggregates, which affect their measured concentration in plasma. Single erythrocyte and platelet EVs are present mainly in the range of 100–200 nm, far below the lower limit of what can be measured by conventional FCM. Furthermore, the effects of single freeze–thaw cycle, time delay between blood collection and plasma preparation up to 1 hour and storage up to 1 year are insignificant (p>0.05) on the measured concentration and diameter of EVs from erythrocyte and platelet concentrates and EVs in plasma, urine and saliva. In conclusion, in standard protocols for EV studies, centrifugation to isolate EVs from collected body fluids should be avoided. Freezing and storage of collected body fluids, albeit their insignificant effects, should be performed identically for comparative EV studies and to create reliable biorepositories. PMID:26563735

  9. Handling and storage of human body fluids for analysis of extracellular vesicles.

    PubMed

    Yuana, Yuana; Böing, Anita N; Grootemaat, Anita E; van der Pol, Edwin; Hau, Chi M; Cizmar, Petr; Buhr, Egbert; Sturk, Auguste; Nieuwland, Rienk

    2015-01-01

    Because procedures of handling and storage of body fluids affect numbers and composition of extracellular vesicles (EVs), standardization is important to ensure reliable and comparable measurements of EVs in a clinical environment. We aimed to develop standard protocols for handling and storage of human body fluids for EV analysis. Conditions such as centrifugation, single freeze-thaw cycle, effect of time delay between blood collection and plasma preparation and storage were investigated. Plasma is the most commonly studied body fluid in EV research. We mainly focused on EVs originating from platelets and erythrocytes and investigated the behaviour of these 2 types of EVs independently as well as in plasma samples of healthy subjects. EVs in urine and saliva were also studied for comparison. All samples were analysed simultaneously before and after freeze-thawing by resistive pulse sensing, nanoparticle tracking analysis, conventional flow cytometry (FCM) and transmission (scanning) electron microscopy. Our main finding is that the effect of centrifugation markedly depends on the cellular origin of EVs. Whereas erythrocyte EVs remain present as single EVs after centrifugation, platelet EVs form aggregates, which affect their measured concentration in plasma. Single erythrocyte and platelet EVs are present mainly in the range of 100-200 nm, far below the lower limit of what can be measured by conventional FCM. Furthermore, the effects of single freeze-thaw cycle, time delay between blood collection and plasma preparation up to 1 hour and storage up to 1 year are insignificant (p>0.05) on the measured concentration and diameter of EVs from erythrocyte and platelet concentrates and EVs in plasma, urine and saliva. In conclusion, in standard protocols for EV studies, centrifugation to isolate EVs from collected body fluids should be avoided. Freezing and storage of collected body fluids, albeit their insignificant effects, should be performed identically for comparative EV studies and to create reliable biorepositories.

  10. First-line gefitinib in Caucasian EGFR mutation-positive NSCLC patients: a phase-IV, open-label, single-arm study

    PubMed Central

    Douillard, J-Y; Ostoros, G; Cobo, M; Ciuleanu, T; McCormack, R; Webster, A; Milenkova, T

    2014-01-01

    Background: Phase-IV, open-label, single-arm study (NCT01203917) to assess efficacy and safety/tolerability of first-line gefitinib in Caucasian patients with stage IIIA/B/IV, epidermal growth factor receptor (EGFR) mutation-positive non-small-cell lung cancer (NSCLC). Methods: Treatment: gefitinib 250 mg day−1 until progression. Primary endpoint: objective response rate (ORR). Secondary endpoints: disease control rate (DCR), progression-free survival (PFS), overall survival (OS) and safety/tolerability. Pre-planned exploratory objective: EGFR mutation analysis in matched tumour and plasma samples. Results: Of 1060 screened patients with NSCLC (859 known mutation status; 118 positive, mutation frequency 14%), 106 with EGFR sensitising mutations were enrolled (female 70.8% adenocarcinoma 97.2% never-smoker 64.2%). At data cutoff: ORR 69.8% (95% confidence interval (CI) 60.5–77.7), DCR 90.6% (95% CI 83.5–94.8), median PFS 9.7 months (95% CI 8.5–11.0), median OS 19.2 months (95% CI 17.0–NC; 27% maturity). Most common adverse events (AEs; any grade): rash (44.9%), diarrhoea (30.8%); CTC (Common Toxicity Criteria) grade 3/4 AEs: 15% SAEs: 19%. Baseline plasma 1 samples were available in 803 patients (784 known mutation status; 82 positive; mutation frequency 10%). Plasma 1 EGFR mutation test sensitivity: 65.7% (95% CI 55.8–74.7). Conclusion: First-line gefitinib was effective and well tolerated in Caucasian patients with EGFR mutation-positive NSCLC. Plasma samples could be considered for mutation analysis if tumour tissue is unavailable. PMID:24263064

  11. Profiling of the compounds absorbed in human plasma and urine after oral administration of a traditional Japanese (kampo) medicine, daikenchuto.

    PubMed

    Iwabu, Jun; Watanabe, Junko; Hirakura, Kazuhiro; Ozaki, Yoshinori; Hanazaki, Kazuhiro

    2010-11-01

    Daikenchuto (DKT), a pharmaceutical-grade traditional Japanese (Kampo) medicine, has been widely used for the treatment of various gastrointestinal disorders including postoperative ileus and has been integrated into the modern medical care system in Japan as a prescription drug. DKT is a multiherbal medicine consisting of Japanese pepper (zanthoxylum fruit), processed ginger, and ginseng with maltose as an additive. Despite substantial research on the pharmacological activities of DKT and its ingredients, the lack of studies on absorption, distribution, metabolism, and excretion of DKT has made it difficult to obtain a consistent picture of its mechanism of action. In the present study, we constructed an analysis procedure consisting of seven conditions of liquid chromatography and mass spectrometric analysis, which enabled the identification of 44 ingredients of DKT component herbs. We investigated the plasma and urine profiles of these ingredients 0.5 to 8 h after oral administration of 15.0 g of DKT in four healthy volunteers. The results indicated that 1) hydroxy-α-sanshool and [6]-shogaol, the prominent peaks in plasma derived from Japanese pepper and ginger, respectively, were detected at 0.5 h and thereafter decreased throughout the sampling period; 2) ginsenoside Rb(1), a prominent peak derived from ginseng, increased gradually during the sampling period; 3) glucuronide conjugates of hydroxy-sanshools, shogaols, and gingerols were detected in plasma and urine; and 4) no obvious differences between samples from the two male and the two female individuals were observed. These results provide a strong basis for future studies on pharmacokinetics and pharmacology of DKT.

  12. Evaluation of the Mg doping approach for Si mass fractionation correction on Nu Instruments MC-ICP Mass Spectrometers

    NASA Astrophysics Data System (ADS)

    Zhao, Ye; Hsieh, Yu-Te; Belshaw, Nick

    2015-04-01

    Silicon (Si) stable isotopes have been used in a broad range of geochemical and cosmochemical applications. A precise and accurate determination of Si isotopes is desirable to distinguish their small natural variations (< 0.2‰) in many of these studies. In the past decade, the advent of the MC-ICP-MS has spurred a remarkable improvement in the precision and accuracy of Si isotopic analysis. The instrumental mass fractionation correction is one crucial aspect of the analysis of Si isotopes. Two options are currently available: the sample-standard bracketing approach and the Mg doping approach. However, there has been a debate over the validity of the Mg doping approach. Some studies (Cardinal et al., 2003; Engström et al., 2006) favoured it compared to the sample-standard bracketing approach, whereas some other studies (e.g. De La Rocha, 2002) considered it unsuitable. This study investigates the Mg doping approach on both the Nu Plasma II and the Nu Plasma 1700. Experiments were performed in both the wet plasma and the dry plasma modes, using a number of different combinations of cones. A range of different Mg to Si ratios as well as different matrices have been used in the experiments. A sample-standard bracketing approach has also been adopted for the Si mass fractionation correction to compare with the Mg doping approach. Through assessing the mass fractionation behaviours of both Si and Mg under different instrument settings, this study aims to identity the factors which may affect the Mg doping approach and answer some key questions to the debate.

  13. Phylogenetic reconstruction and polymorphism analysis of BK virus VP2 gene isolated from renal transplant recipients in China

    PubMed Central

    WANG, ZHANG-YANG; HONG, WEI-LONG; ZHU, ZHE-HUI; CHEN, YUN-HAO; YE, WEN-LE; CHU, GUANG-YU; LI, JIA-LIN; CHEN, BI-CHENG; XIA, PENG

    2015-01-01

    BK polyomavirus (BKV) is important pathogen for kidney transplant recipients, as it is frequently re-activated, leading to nephropathy. The aim of this study was to investigate the phylogenetic reconstruction and polymorphism of the VP2 gene in BKV isolated from Chinese kidney transplant recipients. Phylogenetic analysis was carried out in the VP2 region from 135 BKV-positive samples and 28 reference strains retrieved from GenBank. The unweighted pair-group method with arithmetic mean (UPGMA) grouped all strains into subtypes, but failed to subdivide strains into subgroups. Among the plasma and urine samples, all plasma (23/23) and 82 urine samples (82/95) were identified to contain subtype I; the other 10 urine samples contained subtype IV. A 86-bp fragment was identified as a highly conserved sequence. Following alignment with 36 published BKV sequences from China, 92 sites of polymorphism were identified, including 11 single nucleotide polymorphisms (SNPs) prevalent in Chinese individuals and 30 SNPs that were specific to the two predominant subtypes I and IV. The limitations of the VP2 gene segment in subgrouping were confirmed by phylogenetic analysis. The conserved sequence and polymorphism identified in this study may be helpful in the detection and genotyping of BKV. PMID:26640547

  14. Quantitative analysis of lead in aqueous solutions by ultrasonic nebulizer assisted laser induced breakdown spectroscopy

    NASA Astrophysics Data System (ADS)

    Zhong, Shi-Lei; Lu, Yuan; Kong, Wei-Jin; Cheng, Kai; Zheng, Ronger

    2016-08-01

    In this study, an ultrasonic nebulizer unit was established to improve the quantitative analysis ability of laser-induced breakdown spectroscopy (LIBS) for liquid samples detection, using solutions of the heavy metal element Pb as an example. An analytical procedure was designed to guarantee the stability and repeatability of the LIBS signal. A series of experiments were carried out strictly according to the procedure. The experimental parameters were optimized based on studies of the pulse energy influence and temporal evolution of the emission features. The plasma temperature and electron density were calculated to confirm the LTE state of the plasma. Normalizing the intensities by background was demonstrated to be an appropriate method in this work. The linear range of this system for Pb analysis was confirmed over a concentration range of 0-4,150ppm by measuring 12 samples with different concentrations. The correlation coefficient of the fitted calibration curve was as high as 99.94% in the linear range, and the LOD of Pb was confirmed as 2.93ppm. Concentration prediction experiments were performed on a further six samples. The excellent quantitative ability of the system was demonstrated by comparison of the real and predicted concentrations of the samples. The lowest relative error was 0.043% and the highest was no more than 7.1%.

  15. Evaluation of calcium alginate beads for Ce, La and Nd preconcentration from groundwater prior to ICP OES analysis.

    PubMed

    Arantes de Carvalho, Gabriel G; Kondaveeti, Stalin; Petri, Denise F S; Fioroto, Alexandre M; Albuquerque, Luiza G R; Oliveira, Pedro V

    2016-12-01

    Analytical methods for the determination of rare earth elements (REE) in natural waters by plasma spectrochemical techniques often require sample preparation procedures for analytes preconcentration as well as for removing matrix constituents, that may interfere on the analytical measurements. In the present work, calcium alginate (CA) beads were used for the first time aiming at Ce, La and Nd preconcentration from groundwater samples for further determination by inductively coupled plasma optical emission spectrometry (ICP OES). Test samples were analyzed in batch mode by transferring a 40mL test portion (pH=5±0.2) into a 50mL polyethylene flask containing 125mg CA beads. After 15min contact, the analytes were quantitatively extracted from the loaded CA beads with 2.0mL of 1.0molL -1 HCl solution for further determination by ICP OES, using Ce (II) 456.236, La (II) 379.478 and Nd (II) 430.358nm emission lines. The proposed approach is a reliable alternative for REE single-stage preconcentration from aqueous samples, as it provided accurate results based on the addition and recovery analysis of groundwater. The results obtained by the proposed method were also compared with those from reference method based on inductively coupled plasma mass spectrometry (ICP-MS) and no significant differences were observed after applying the Student's t-test at 95% confidence level. Copyright © 2016 Elsevier B.V. All rights reserved.

  16. Parallel ultra high pressure liquid chromatography-mass spectrometry for the quantification of HIV protease inhibitors using dried spot sample collection format.

    PubMed

    Watanabe, Kyoko; Varesio, Emmanuel; Hopfgartner, Gérard

    2014-08-15

    An assay was developed and validated for the quantification of eight protease inhibitors (indinavir (IDV), ritonavir (RTV), lopinavir (LPV), saquinavir (SQV), amprenavir (APV), nelfinavir (NFV), atazanavir (AZV) and darunavir (DRV)) in dried plasma spots using parallel ultra-high performance liquid chromatography and mass spectrometry detection in the multiple reaction monitoring mode. For each analyte an isotopically labeled internal standard was used and the assay based on liquid-solid extraction the area response ratio (analyte/IS) was found to be linear; from 0.025 μg/ml to 20 μg/ml for IDV, SQV, DRV, AZV, LPV, from 0.025 μg/ml to 10 μg/ml for NFV, APV and from 0.025 μg/ml to 5 μg/ml for RTV using 15 μl of plasma spotted on filter paper placed in a sample tube. The total analysis time was of 4 min and inter-assay accuracies and precisions were in the range of 87.7-109% and 2.5-11.8%, respectively. On dried plasma spots all analytes were found to be stable for at least 7 days. Practicability of the assay to blood was also demonstrated. The sample drying process could be reduced to 5 min using a commercial microwave system without any analyte degradation. Together with quantification, confirmatory analysis was performed on representative clinical samples. Copyright © 2014 Elsevier B.V. All rights reserved.

  17. Detection of recombinant EPO in blood and urine samples with EPO WGA MAIIA, IEF and SAR-PAGE after microdose injections.

    PubMed

    Dehnes, Yvette; Shalina, Alexandra; Myrvold, Linda

    2013-01-01

    The misuse of microdoses of performance enhancing drugs like erythropoietin (EPO) constitutes a major challenge in doping analysis. When injected intravenously, the half-life of recombinant human EPO (rhEPO) like epoetin alfa, beta, and zeta is only a few hours and hence, the window for direct detection of rhEPO in urine is small. In order to investigate the detection window for rhEPO directly in blood and urine with a combined affinity chromatography and lateral flow immunoassay (EPO WGA MAIIA), we recruited nine healthy people who each received six intravenously injected microdoses (7.5 IU/kg) of NeoRecormon (epoetin beta) over a period of three weeks. Blood and urine samples were collected in the days following the injections and analyzed with EPO WGA MAIIA as well as the current validated methods for rhEPO; isoelectric focusing (IEF) and sarcosyl polyacrylamide gel electrophoresis (SAR-PAGE). For samples collected 18 h after a microdose, the sensitivity of the EPO WGA MAIIA assay was 100% in plasma and 87.5% in urine samples at the respective 98% specificity threshold levels. In comparison, the sensitivity in plasma and urine was 75% and 100%, respectively, with IEF, and 87.5% in plasma and 100% in urine when analyzed with SAR-PAGE. We conclude that EPO WGA MAIIA is a sensitive assay for the detection of rhEPO, with the potential of being a fast, supplemental screening assay for use in doping analysis.

  18. Statistical Analysis of Variation in the Human Plasma Proteome

    DOE PAGES

    Corzett, Todd H.; Fodor, Imola K.; Choi, Megan W.; ...

    2010-01-01

    Quantifying the variation in the human plasma proteome is an essential prerequisite for disease-specific biomarker detection. We report here on the longitudinal and individual variation in human plasma characterized by two-dimensional difference gel electrophoresis (2-D DIGE) using plasma samples from eleven healthy subjects collected three times over a two week period. Fixed-effects modeling was used to remove dye and gel variability. Mixed-effects modeling was then used to quantitate the sources of proteomic variation. The subject-to-subject variation represented the largest variance component, while the time-within-subject variation was comparable to the experimental variation found in a previous technical variability study where onemore » human plasma sample was processed eight times in parallel and each was then analyzed by 2-D DIGE in triplicate. Here, 21 protein spots had larger than 50% CV, suggesting that these proteins may not be appropriate as biomarkers and should be carefully scrutinized in future studies. Seventy-eight protein spots showing differential protein levels between different individuals or individual collections were identified by mass spectrometry and further characterized using hierarchical clustering. The results present a first step toward understanding the complexity of longitudinal and individual variation in the human plasma proteome, and provide a baseline for improved biomarker discovery.« less

  19. Statistical analysis of variation in the human plasma proteome.

    PubMed

    Corzett, Todd H; Fodor, Imola K; Choi, Megan W; Walsworth, Vicki L; Turteltaub, Kenneth W; McCutchen-Maloney, Sandra L; Chromy, Brett A

    2010-01-01

    Quantifying the variation in the human plasma proteome is an essential prerequisite for disease-specific biomarker detection. We report here on the longitudinal and individual variation in human plasma characterized by two-dimensional difference gel electrophoresis (2-D DIGE) using plasma samples from eleven healthy subjects collected three times over a two week period. Fixed-effects modeling was used to remove dye and gel variability. Mixed-effects modeling was then used to quantitate the sources of proteomic variation. The subject-to-subject variation represented the largest variance component, while the time-within-subject variation was comparable to the experimental variation found in a previous technical variability study where one human plasma sample was processed eight times in parallel and each was then analyzed by 2-D DIGE in triplicate. Here, 21 protein spots had larger than 50% CV, suggesting that these proteins may not be appropriate as biomarkers and should be carefully scrutinized in future studies. Seventy-eight protein spots showing differential protein levels between different individuals or individual collections were identified by mass spectrometry and further characterized using hierarchical clustering. The results present a first step toward understanding the complexity of longitudinal and individual variation in the human plasma proteome, and provide a baseline for improved biomarker discovery.

  20. Assays for hydrophilic and lipophilic antioxidant capacity (oxygen radical absorbance capacity (ORAC(FL))) of plasma and other biological and food samples.

    PubMed

    Prior, Ronald L; Hoang, Ha; Gu, Liwei; Wu, Xianli; Bacchiocca, Mara; Howard, Luke; Hampsch-Woodill, Maureen; Huang, Dejian; Ou, Boxin; Jacob, Robert

    2003-05-21

    Methods are described for the extraction and analysis of hydrophilic and lipophilic antioxidants, using modifications of the oxygen radical absorbing capacity (ORAC(FL)) procedure. These methods provide, for the first time, the ability to obtain a measure of "total antioxidant capacity" in the protein free plasma, using the same peroxyl radical generator for both lipophilic and hydrophilic antioxidants. Separation of the lipophilic and hydrophilic antioxidant fractions from plasma was accomplished by extracting with hexane after adding water and ethanol to the plasma (hexane/plasma/ethanol/water, 4:1:2:1, v/v). Lipophilic and hydrophilic antioxidants were efficiently partitioned between hexane and aqueous solvents. Conditions for controlling temperature effects and decreasing assay variability using fluorescein as the fluorescent probe were validated in different laboratories. Incubation (37 degrees C for at least 30 min) of the buffer to which AAPH was dissolved was critical in decreasing assay variability. Lipophilic antioxidants represented 33.1 +/- 1.5 and 38.2 +/- 1.9% of the total antioxidant capacity of the protein free plasma in two independent studies of 6 and 10 subjects, respectively. Methods are described for application of the assay techniques to other types of biological and food samples.

Top