Sample records for plasma samples derived

  1. Parvovirus B19V DNA contamination in Chinese plasma and plasma derivatives

    PubMed Central

    2012-01-01

    Background To ensure the safety of plasma derivatives, screening for human parvovirus B19V genomic DNA in donated plasma using a pooling strategy is performed in some countries. We investigated the prevalence of B19V DNA and anti-B19V antibodies in Chinese plasma pools, plasma derivatives and plasma donations to evaluate the risk posed by B19V. Methods Using a Q-PCR assay developed in-house, we tested for B19V genomic DNA in 142 plasma pools collected between January 2009 and June 2011 from two Chinese blood products manufacturers. Plasma derivatives collected between 1993–1995 (10 batches of albumin, 155 batches of intravenous immunoglobulin, IVIG) and 2009–2011 (50 batches of albumin, 54 batches of IVIG, 35 batches of factor VIII, 7 batches of fibrinogen, and 17 batches of prothrombin complex concentrate, PCC) were also tested for B19V contamination. In addition, B19V genome prevalence in minipools(including 90 individual donations) of 49680 individual plasma samples collected between August 2011 and March 2012 by a single Chinese manufacturer was investigated. IgM/IgG was also investigated in plasma pools/derivatives and in minipools with B19V-DNA titers above 1x104 and 1x106 geq/mL using B19 ELISA IgM/IgG assay(Virion-Serion, Würzburg, Germany), respectively. Results B19V-DNA was detected in 54.2% of plasma pools from two Chinese blood product manufacturers; among recently produced blood products, B19V was detected in 21/54 IVIG samples, 19/35 factor VIII samples, 6/7 fibrinogen samples, and 12/17 PCC samples, but not in albumin samples. The levels of B19V-DNA in these samples varied from 102-107 geq/mL. In samples with >104 geq/mL genome DNA, B19V-specific IgG was also found in all corresponding plasma pools and IVIG, whereas none was detected in the majority of other plasma derivatives. Screening of plasma donations indicated that most minipools were contaminated with B19V-DNA (102-108 geq/mL) and one donation had 1.09 × 1010 geq/mL B19V genomic DNA along with a non-classical IgG/IgM profile. Conclusions Despite the implementation of some inactivation/removal methods designed to prevent viral contamination, B19V DNA was detectable in Chinese plasma pools and plasma derivatives. Thus, the introduction of B19V screening and discard donation with high viramic concentration for Chinese plasma donors would be desirable. PMID:22978673

  2. A system of equations to approximate the pharmacokinetic parameters of lacosamide at steady state from one plasma sample.

    PubMed

    Cawello, Willi; Schäfer, Carina

    2014-08-01

    Frequent plasma sampling to monitor pharmacokinetic (PK) profile of antiepileptic drugs (AEDs), is invasive, costly and time consuming. For drugs with a well-defined PK profile, such as AED lacosamide, equations can accurately approximate PK parameters from one steady-state plasma sample. Equations were derived to approximate steady-state peak and trough lacosamide plasma concentrations (Cpeak,ss and Ctrough,ss, respectively) and area under concentration-time curve during dosing interval (AUCτ,ss) from one plasma sample. Lacosamide (ka: ∼2 h(-1); ke: ∼0.05 h(-1), corresponding to half-life of 13 h) was calculated to reach Cpeak,ss after ∼1 h (tmax,ss). Equations were validated by comparing approximations to reference PK parameters obtained from single plasma samples drawn 3-12h following lacosamide administration, using data from double-blind, placebo-controlled, parallel-group PK study. Values of relative bias (accuracy) between -15% and +15%, and root mean square error (RMSE) values≤15% (precision) were considered acceptable for validation. Thirty-five healthy subjects (12 young males; 11 elderly males, 12 elderly females) received lacosamide 100mg/day for 4.5 days. Equation-derived PK values were compared to reference mean Cpeak,ss, Ctrough,ss and AUCτ,ss values. Equation-derived PK data had a precision of 6.2% and accuracy of -8.0%, 2.9%, and -0.11%, respectively. Equation-derived versus reference PK values for individual samples obtained 3-12h after lacosamide administration showed correlation (R2) range of 0.88-0.97 for AUCτ,ss. Correlation range for Cpeak,ss and Ctrough,ss was 0.65-0.87. Error analyses for individual sample comparisons were independent of time. Derived equations approximated lacosamide Cpeak,ss, Ctrough,ss and AUCτ,ss using one steady-state plasma sample within validation range. Approximated PK parameters were within accepted validation criteria when compared to reference PK values. Copyright © 2014 Elsevier B.V. All rights reserved.

  3. Assay of free captopril in human plasma as monobromobimane derivative, using RPLC/(+)ESI/MS/MS: validation aspects and bioequivalence evaluation.

    PubMed

    Medvedovici, Andrei; Albu, Florin; Sora, Iuliana Daniela; Udrescu, Stefan; Galaon, Toma; David, Victor

    2009-10-01

    A sensitive method for determination of free captopril as monobromobimane derivative in plasma samples is discussed. The internal standard (IS) was 5-methoxy-1H-benzimidazole-2-thiol. Derivatization with monobromobimane immediately after blood collection and plasma preparation prevents oxidation of captopril to the corresponding disulfide compound and enhances the ionization yield. Consequently, derivatization enhances sample stability and detection sensitivity. Addition of the internal standard was made immediately after plasma preparation. The internal standard was also derivatized by monobromobimane, as it contains a thiol functional group. Preparation of plasma samples containing captopril and IS derivatives was based upon protein precipitation through addition of acetonitrile, in a volumetric ratio 1:2. The reversed-phase liquid chromatographic separation was achieved on a rapid resolution cartridge Zorbax SB-C(18), monitored through positive electrospray ionization and tandem MS detection using the multiple-reaction monitoring mode. Transitions were 408-362 amu for the captopril derivative and 371-260 amu for the internal standard derivative. The kinetics of captopril oxidation to the corresponding disulfide compound in plasma matrix was also studied using the proposed method. A linear log-log calibration was obtained over the concentration interval 2.5-750 ng/mL. A low limit of quantitation in the 2.5 ng/mL range was obtained. The analytical method was fully validated and successfully applied in a three-way, three-period, single-dose (50 mg), block-randomized bioequivalence study for two pharmaceutical formulations (captopril LPH 25 and 50 mg) against the comparator Capoten 50 mg. Copyright (c) 2009 John Wiley & Sons, Ltd.

  4. Protein adducts as biomarkers of exposure to aromatic diisocyanates in workers manufacturing polyurethane (PUR) foam.

    PubMed

    Säkkinen, Kirsi; Tornaeus, Jarkko; Hesso, Antti; Hirvonen, Ari; Vainio, Harri; Norppa, Hannu; Rosenberg, Christina

    2011-04-01

    This work was undertaken to investigate the usefulness of diisocyanate-related protein adducts in blood samples as biomarkers of occupational exposure to toluene diisocyanate (TDI; 2,4- and 2,6-isomers) and 4,4'-methylenediphenyl diisocyanate (MDI). Quantification of adducts as toluene diamines (TDAs) and methylenedianiline (MDA) was performed on perfluoroacylated derivatives by gas chromatography-mass spectrometry (GC-MS/MS) in negative chemical ionisation mode. TDI-derived adducts were found in 77% of plasma and in 59% of globin samples from exposed workers manufacturing flexible polyurethane foam. The plasma levels ranged from 0.003 to 0.58 nmol mL(-1) and those in globin from 0.012 to 0.33 nmol g(-1). The 2,6-isomer amounted to about two-thirds of the sum concentration of TDA isomers. MDI-derived adducts were detected in 3.5% of plasma and in 7% of globin samples from exposed workers manufacturing rigid polyurethane foam. A good correlation was found between the sum of TDA isomers in urine and that in plasma. The relationship between globin adducts and urinary metabolites was ambiguous. Monitoring TDI-derived TDA in plasma thus appears to be an appropriate method for assessing occupational exposure. Contrary to TDI exposure, adducts in plasma or globin were not useful in assessing workers' exposure to MDI. An important outcome of the study was that no amine-related adducts were detected in globin samples from TDI- or MDI-exposed workers, alleviating concerns that TDI or MDI might pose a carcinogenic hazard. Further studies are nevertheless required to judge whether diisocyanates per se could be such a hazard.

  5. Peptidomic analysis of endogenous plasma peptides from patients with pancreatic neuroendocrine tumours.

    PubMed

    Kay, Richard G; Challis, Benjamin G; Casey, Ruth T; Roberts, Geoffrey P; Meek, Claire L; Reimann, Frank; Gribble, Fiona M

    2018-06-01

    Diagnosis of pancreatic neuroendocrine tumours requires the study of patient plasma with multiple immunoassays, using multiple aliquots of plasma. The application of mass spectrometry based techniques could reduce the cost and amount of plasma required for diagnosis. Plasma samples from two patients with pancreatic neuroendocrine tumours were extracted using an established acetonitrile based plasma peptide enrichment strategy. The circulating peptidome was characterised using nano and high flow rate LC/MS analyses. To assess the diagnostic potential of the analytical approach, a large sample batch (68 plasmas) from control subjects, and aliquots from subjects harbouring two different types of pancreatic neuroendocrine tumour (insulinoma and glucagonoma) were analysed using a 10-minute LC/MS peptide screen. The untargeted plasma peptidomics approach identified peptides derived from the glucagon prohormone, chromogranin A, chromogranin B and other peptide hormones and proteins related to control of peptide secretion. The glucagon prohormone derived peptides that were detected were compared against putative peptides that were identified using multiple antibody pairs against glucagon peptides. Comparison of the plasma samples for relative levels of selected peptides showed clear separation between the glucagonoma and the insulinoma and control samples. The combination of the organic solvent extraction methodology with high flow rate analysis could potentially be used to aid diagnosis and monitor treatment of patients with functioning pancreatic neuroendocrine tumours. However, significant validation will be required before this approach can be clinically applied. This article is protected by copyright. All rights reserved.

  6. Simplifying [18F]GE-179 PET: are both arterial blood sampling and 90-min acquisitions essential?

    PubMed

    McGinnity, Colm J; Riaño Barros, Daniela A; Trigg, William; Brooks, David J; Hinz, Rainer; Duncan, John S; Koepp, Matthias J; Hammers, Alexander

    2018-06-11

    The NMDA receptor radiotracer [ 18 F]GE-179 has been used with 90-min scans and arterial plasma input functions. We explored whether (1) arterial blood sampling is avoidable and (2) shorter scans are feasible. For 20 existing [ 18 F]GE-179 datasets, we generated (1) standardised uptake values (SUVs) over eight intervals; (2) volume of distribution (V T ) images using population-based input functions (PBIFs), scaled using one parent plasma sample; and (3) V T images using three shortened datasets, using the original parent plasma input functions (ppIFs). Correlations with the original ppIF-derived 90-min V T s increased for later interval SUVs (maximal ρ = 0.78; 80-90 min). They were strong for PBIF-derived V T s (ρ = 0.90), but between-subject coefficient of variation increased. Correlations were very strong for the 60/70/80-min original ppIF-derived V T s (ρ = 0.97-1.00), which suffered regionally variant negative bias. Where arterial blood sampling is available, reduction of scan duration to 60 min is feasible, but with negative bias. The performance of SUVs was more consistent across participants than PBIF-derived V T s.

  7. The Modification of Cellulosic Surface with Fatty Acids via Plasma Mediated Reactions

    NASA Astrophysics Data System (ADS)

    Nada, Ahmed Ali Ahmed

    Much attention has been paid recently to understand the healing process made by the human body, in order to develop new approaches for promoting healing. The wound healing process includes four main phases, namely, hemostatic, inflammatory, proliferation, and remodeling, which take place successively. The human body can provide all the requirements of the healing process in normal wounds, unless there is a kind of deficiency of the skin function or massive fluid losses of vast wounds. Therefore, wound care of non-healing wounds has recently been the growing concern of many applications. The goal of this work is to explore the development of a new cellulose-based wound dressing composite that contain or release wound healing agents attained via dry textile chemical finishing techniques (thermal curing-plasma treatment). The synthesis of different wound healing agents derived from fatty acids and attached chemically to cellulose or even delivered through cyclodextrine modified cellulose are reported in this work. First, free fatty acids, which are obtained from commercial vegetable oils, were identified as wound healing agents. Many of these free acids are known to bind with and deactivate the proteases associated with inflammation at a wound site. Linoleic acid is extracted from commercial products of safflower seed oil while ricinoleic acid is obtained from castor oil. Conjugated linoleic acid was synthesized. Un-conjugated linoleic acid was used to prepare two derivatives namely linoleic azide and allylic ketone of linoleic acid. Different cellulose derivatives such as cellulose peroxide, iododeoxycellulose and cellulose diazonium salt in different degree of substitutions were synthesized in order to facilitate the free radical reaction with the fatty acid derivatives. New modified cellulosic products were synthesized by reacting the cellulosic and the linoleic acid derivatives via thermal or plasma technique and characterized by FT-IR ATR, the wettability test, etc. The cyto-compatiability of the new product was investigated using the cytotoxicity test to identify the cytotoxic potentials of the grafted samples. The highest yield was obtained in the thermal curing (at 140°C, 3 min, and a 20% solution of azide derivative -- 170°C, 3 min, and a 2.5% solution of allylic ketone derivatives) of the iododeoxycellulose fabrics with either linoleic azide or the allylic ketone derivative. Atmospheric plasma machines were used for this study such as NCAPS (dielectric barrier discharge plasma) and APJeT. APJet plasma machine was used in two different modes namely downstream and in-situ. Although, the plasma treatment uses a lower energy to achieve the chemical reactions between the two components, the APJet obtained good results in the in-situ mode (at 800 Watts/cm3 RF power, 45 sec. exposure time) while retaining sufficient tensile strength. In general samples treated with the allylic ketone of linoleic acid treated samples showed higher graft yield than the azide derivative, especially those treated via thermal curing. Moreover, they are more cytologically compatible than the plasma treated samples. In the course of producing a wound healing product that contains or releases fatty acids, allylic beta-CD was synthesized for first time as a textile finishing agent. Per(2, 3, 6- tri-O-allyl)-beta-CD was synthesized and characterized using spectral analysis. Cellulosic derivatives were treated with per(2, 3, 6- tri-O-allyl)-beta-CD via either pad-thermofixation technique or plasma treatment. Thermal treatment showed superior efficiency over plasma techniques to activate the vinyl groups and creating a self-assembled CD network chemically bonded with the cellulose derivatives (at 180°C, 3 min, and a 20 % solution of Per(2, 3, 6- tri- O-allyl)-beta-CD). APJeT machine (in-situ mode) succeeded only to activate cellulose/ allylic CD reaction, but however, it could not offer enough energy to stimulate vinyl-vinyl reactions. Oleic acid with its semi-linear chemical structure tends to include in the CD cavity faster and to higher levels, than the others after 4 hrs at 25°C. At higher temperatures the equilibrium of free and included oleic acid shifts and a remarkable decrease in the total inclusion was observed. However, ricinoleic acid anions showed very poor tendency for inclusion either with high temperature or at long time which may be attributed to its chemical structure, which is too large for the CD cavities. Also, un-conjugated linoleic acid anions showed higher inclusion than the conjugated ones. MMT assay was used to determine the cyto- compatibility for the newly modified samples. Generally speaking, the highest fixation yields the highest cyto-compatibility of the treated samples. Iododeoxycellulose samples in both thermal and plasma curing reported high cyto-compatibility either with allylic ketone or azide derivative of linoleic acid over the other cellulose derivatives. Pure extracted fatty acids or included ones showed high cyto-compatibility towards L929 mouse cell line.

  8. Diagnostic value of plasma and bronchoalveolar lavage samples in acute lung allograft rejection: differential cytology.

    PubMed

    Speck, Nicole E; Schuurmans, Macé M; Murer, Christian; Benden, Christian; Huber, Lars C

    2016-06-21

    Diagnosis of acute lung allograft rejection is currently based on transbronchial lung biopsies. Additional methods to detect acute allograft dysfunction derived from plasma and bronchoalveolar lavage samples might facilitate diagnosis and ultimately improve allograft survival. This review article gives an overview of the cell profiles of bronchoalveolar lavage and plasma samples during acute lung allograft rejection. The value of these cells and changes within the pattern of differential cytology to support the diagnosis of acute lung allograft rejection is discussed. Current findings on the topic are highlighted and trends for future research are identified.

  9. Improved circulating microparticle analysis in acid-citrate dextrose (ACD) anticoagulant tube.

    PubMed

    György, Bence; Pálóczi, Krisztina; Kovács, Alexandra; Barabás, Eszter; Bekő, Gabriella; Várnai, Katalin; Pállinger, Éva; Szabó-Taylor, Katalin; Szabó, Tamás G; Kiss, Attila A; Falus, András; Buzás, Edit I

    2014-02-01

    Recently extracellular vesicles (exosomes, microparticles also referred to as microvesicles and apoptotic bodies) have attracted substantial interest as potential biomarkers and therapeutic vehicles. However, analysis of microparticles in biological fluids is confounded by many factors such as the activation of cells in the blood collection tube that leads to in vitro vesiculation. In this study we aimed at identifying an anticoagulant that prevents in vitro vesiculation in blood plasma samples. We compared the levels of platelet microparticles and non-platelet-derived microparticles in platelet-free plasma samples of healthy donors. Platelet-free plasma samples were isolated using different anticoagulant tubes, and were analyzed by flow cytometry and Zymuphen assay. The extent of in vitro vesiculation was compared in citrate and acid-citrate-dextrose (ACD) tubes. Agitation and storage of blood samples at 37 °C for 1 hour induced a strong release of both platelet microparticles and non-platelet-derived microparticles. Strikingly, in vitro vesiculation related to blood sample handling and storage was prevented in samples in ACD tubes. Importantly, microparticle levels elevated in vivo remained detectable in ACD tubes. We propose the general use of the ACD tube instead of other conventional anticoagulant tubes for the assessment of plasma microparticles since it gives a more realistic picture of the in vivo levels of circulating microparticles and does not interfere with downstream protein or RNA analyses. Copyright © 2013 Elsevier Ltd. All rights reserved.

  10. Inactivation of Zika virus by solvent/detergent treatment of human plasma and other plasma-derived products and pasteurization of human serum albumin.

    PubMed

    Kühnel, Denis; Müller, Sebastian; Pichotta, Alexander; Radomski, Kai Uwe; Volk, Andreas; Schmidt, Torben

    2017-03-01

    In 2016 the World Health Organization declared the mosquito-borne Zika virus (ZIKV) a "public health emergency of international concern." ZIKV is a blood-borne pathogen, which therefore causes concerns regarding the safety of human plasma-derived products due to potential contamination of the blood supply. This study investigated the effectiveness of viral inactivation steps used during the routine manufacturing of various plasma-derived products to reduce ZIKV infectivity. Human plasma and intermediates from the production of various plasma-derived products were spiked with ZIKV and subjected to virus inactivation using the identical techniques (either solvent/detergent [S/D] treatment or pasteurization) and conditions used for the actual production of the respective products. Samples were taken and the viral loads measured before and after inactivation. After S/D treatment of spiked intermediates of the plasma-derived products Octaplas(LG), Octagam, and Octanate, the viral loads were below the limit of detection in all cases. The mean log reduction factor (LRF) was at least 6.78 log for Octaplas(LG), at least 7.00 log for Octagam, and at least 6.18 log for Octanate after 60, 240, and 480 minutes of S/D treatment, respectively. For 25% human serum albumin (HSA), the mean LRF for ZIKV was at least 7.48 log after pasteurization at 60°C for 120 minutes. These results demonstrate that the commonly used virus inactivation processes utilized during the production of human plasma and plasma-derived products, namely, S/D treatment or pasteurization, are effective for inactivation of ZIKV. © 2016 The Authors Transfusion published by Wiley Periodicals, Inc. on behalf of AABB.

  11. Validation of a LC-fluorescence method for determination of free captopril in human plasma, using a pre-column derivatization reaction with monobromobimane.

    PubMed

    Tache, Florentin; Farca, Alexandru; Medvedovici, Andrei; David, Victor

    2002-05-15

    Both derivatization of free captopril in human plasma samples using monobromobimane as fluorescent label and the corresponding HPLC-fluorescence detection (FLD) method were validated. Calibration curve for the fluorescent captopril derivative in plasma samples is linear in the ppb-ppm range with a detection limit of 4 ppb and an identification limit of 10 ppb (P%: 90; nu > or = 5). These methods were successfully applied on bioequivalence studies carried out on some marketed pharmaceutical formulations.

  12. Plasma-derived microparticles in polycythaemia vera.

    PubMed

    Ahadon, M; Abdul Aziz, S; Wong, C L; Leong, C F

    2018-04-01

    Microparticles are membrane bound vesicles, measuring less than 1.0 um, which are released during cellular activation or during apoptosis. Studies have shown that these circulating microparticles play a role in coagulation, cell signaling and cellular interactions. Increased levels of circulating microparticles have been observed in a number of conditions where there is vascular dysfunction, thrombosis and inflammation. The objective of this study was to determine the various plasma-derived microparticles in patients with polycythaemia vera (PV) in Universiti Kebangsaan Malaysia Medical Centre and to compare them with normal control. A total of 15 patients with PV and 15 healthy volunteers were included in this cross-sectional descriptive study. Plasma samples from both patients and healthy volunteers were prepared and further processed for isolation of microparticles. Flow cytometry analyses were then carried out in all samples to determine the cellular origin of the microparticles. Full blood count parameters for both groups were also collected. Data collected were analyzed using SPSS version 12.0. Patients with PV had a significantly higher percentage of platelet derived microparticles compared to healthy controls (P <0.05). The control group had a higher level of endothelial derived microparticles but the differences were not statistically significant (P > 0.05). The median percentage of positive events for platelet derived microparticles was higher in patients with PV compared to normal healthy controls.

  13. Extractive alkylation of 6-mercaptopurine and determination in plasma by gas chromatography-mass spectrometry.

    PubMed

    Floberg, S; Hartvig, P; Lindström, B; Lönner-Holm, G; Odlind, B

    1981-09-11

    An analytical procedure was developed for the determination of 6-mercaptopurine in plasma. Owing to the polar character and low plasma concentration of the compound, extraction and derivatization was carried out directly from the plasma sample by extractive alkylation. Determination was made using gas chromatography-mass spectrometry with multiple-ion detection. Conditions with respect to the rate of formation and the stability of the derivative formed in the extractive alkylation step were evaluated. The selectively of the method to azathioprine and to metabolites was thoroughly investigated. No 6-mercaptopurine was formed from azathioprine added to water or plasma and run through the method. The method enables the detection of 2 ng of 6 mercaptopurine in a 1.0-ml plasma sample. Quantitative determinations were done down to 10 ng/ml 6 mercaptopurine in plasma.

  14. Evaluation of Digital PCR as a Technique for Monitoring Acute Rejection in Kidney Transplantation.

    PubMed

    Lee, Hyeseon; Park, Young-Mi; We, Yu-Mee; Han, Duck Jong; Seo, Jung-Woo; Moon, Haena; Lee, Yu-Ho; Kim, Yang-Gyun; Moon, Ju-Young; Lee, Sang-Ho; Lee, Jong-Keuk

    2017-03-01

    Early detection and proper management of kidney rejection are crucial for the long-term health of a transplant recipient. Recipients are normally monitored by serum creatinine measurement and sometimes with graft biopsies. Donor-derived cell-free deoxyribonucleic acid (cfDNA) in the recipient's plasma and/or urine may be a better indicator of acute rejection. We evaluated digital PCR (dPCR) as a system for monitoring graft status using single nucleotide polymorphism (SNP)-based detection of donor DNA in plasma or urine. We compared the detection abilities of the QX200, RainDrop, and QuantStudio 3D dPCR systems. The QX200 was the most accurate and sensitive. Plasma and/or urine samples were isolated from 34 kidney recipients at multiple time points after transplantation, and analyzed by dPCR using the QX200. We found that donor DNA was almost undetectable in plasma DNA samples, whereas a high percentage of donor DNA was measured in urine DNA samples, indicating that urine is a good source of cfDNA for patient monitoring. We found that at least 24% of the highly polymorphic SNPs used to identify individuals could also identify donor cfDNA in transplant patient samples. Our results further showed that autosomal, sex-specific, and mitochondrial SNPs were suitable markers for identifying donor cfDNA. Finally, we found that donor-derived cfDNA measurement by dPCR was not sufficient to predict a patient's clinical condition. Our results indicate that donor-derived cfDNA is not an accurate predictor of kidney status in kidney transplant patients.

  15. Immunoaffinity based methods are superior to kits for purification of prostate derived extracellular vesicles from plasma samples.

    PubMed

    Brett, Sabine I; Lucien, Fabrice; Guo, Charles; Williams, Karla C; Kim, Yohan; Durfee, Paul N; Brinker, C J; Chin, Joseph I; Yang, Jun; Leong, Hon S

    2017-05-01

    The ability to isolate extracellular vesicles (EVs) such as exosomes or microparticles is an important method that is currently not standardized. While commercially available kits offer purification of EVs from biofluids, such purified EV samples will also contain non-EV entities such as soluble protein and nucleic acids that could confound subsequent experimentation. Ideally, only EVs would be isolated and no soluble protein would be present in the final EV preparation. We compared commercially available EV isolation kits with immunoaffinity purification techniques and evaluated our final EV preparations using atomic force microscopy (AFM) and nanoscale flow cytometry (NFC). AFM is the only modality capable of detecting distinguishing soluble protein from EVs which is important for downstream proteomics approaches. NFC is the only technique capable of quantitating the proportion of target EVs to non-target EVs in the final EV preparation. To determine enrichment of prostate derived EVs relative to non-target MPs, anti-PSMA (Prostate Specific Membrane Antigen) antibodies were used in NFC. Antibody-based immunoaffinity purification generated the highest quality of prostate derived EV preparations due to the lack of protein and RNA present in the samples. All kits produced poor purity EV preparations that failed to deplete the sample of plasma protein. While attractive due to their ease of use, EV purification kits do not provide substantial improvements in isolation of EVs from biofluids such as plasma. Immunoaffinity approaches are more efficient and economical and will also eliminate a significant portion of plasma proteins which is necessary for downstream approaches. © 2017 Wiley Periodicals, Inc.

  16. Quantification of isotope-labelled and unlabelled folates in plasma, ileostomy and food samples.

    PubMed

    Büttner, Barbara E; Öhrvik, Veronica E; Witthöft, Cornelia M; Rychlik, Michael

    2011-01-01

    New stable isotope dilution assays were developed for the simultaneous quantitation of [(13)C(5)]-labelled and unlabelled 5-methyltetrahydrofolic acid, 5-formyltetrahydrofolic acid, folic acid along with unlabelled tetrahydrofolic acid and 10-formylfolic acid in clinical samples deriving from human bioavailability studies, i.e. plasma, ileostomy samples, and food. The methods were based on clean-up by strong anion exchange followed by LC-MS/MS detection. Deuterated analogues of the folates were applied as the internal standards in the stable isotope dilution assays. Assay sensitivity was sufficient to detect all relevant folates in the respective samples as their limits of detection were below 0.62 nmol/L in plasma and below 0.73 μg/100 g in food or ileostomy samples. Quantification of the [(13)C(5)]-label in clinical samples offers the possibility to differentiate between folate from endogenous body pools and the administered dose when executing bioavailability trials.

  17. Tantalum-tungsten oxide thermite composites prepared by sol-gel synthesis and spark plasma sintering

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kuntz, Joshua D.; Gash, Alexander E.; Cervantes, Octavio G.

    2010-08-15

    Energetic composite powders consisting of sol-gel derived nanostructured tungsten oxide were produced with various amounts of micrometer-scale tantalum fuel metal. Such energetic composite powders were ignition-tested and the results show that the powders are not sensitive to friction, spark and/or impact ignition. Initial consolidation experiments, using the High-Pressure Spark Plasma Sintering (HPSPS) technique, on the sol-gel derived nanostructured tungsten oxide produced samples with higher relative density than can be achieved with commercially available tungsten oxide. The sol-gel derived nanostructured tungsten oxide with immobilized tantalum fuel metal (Ta-WO{sub 3}) energetic composite was consolidated to a density of 9.17 g cm{sup -3}more » or 93% relative density. In addition, those samples were consolidated without significant pre-reaction of the constituents, thus retaining their stored chemical energy. (author)« less

  18. Tantalum-Tungsten Oxide Thermite Composite Prepared by Sol-Gel Synthesis and Spark Plasma Sintering

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cervantes, O; Kuntz, J; Gash, A

    2009-02-13

    Energetic composite powders consisting of sol-gel derived nanostructured tungsten oxide were produced with various amounts of micrometer-scale tantalum fuel metal. Such energetic composite powders were ignition tested and results show that the powders are not sensitive to friction, spark and/or impact ignition. Initial consolidation experiments, using the High Pressure Spark Plasma Sintering (HPSPS) technique, on the sol-gel derived nanostructured tungsten oxide produced samples with higher relative density than can be achieved with commercially available tungsten oxide. The sol-gel derived nanostructured tungsten oxide with immobilized tantalum fuel metal (Ta - WO{sub 3}) energetic composite was consolidated to a density of 9.17more » g.cm{sup -3} or 93% relative density. In addition those parts were consolidated without significant pre-reaction of the constituents, thus the sample retained its stored chemical energy.« less

  19. Visible light emission measurements from a dense electrothermal launcher plasma

    NASA Astrophysics Data System (ADS)

    Hankins, O. E.; Bourham, M. A.; Earnhart, J.; Gilligan, J. G.

    1993-01-01

    Measurements of the visible light emission from dense, weakly non-ideal plasmas have been performed on the experimental electrothermal launcher device 'SIRENS'. The plasma is created by the ablation or a Lexan insulator in the source, which then flows through a cylindrical barrel which serves as the material sample. Visible light emission spectra have been observed both in-bore and from the muzzle flash or the barrel, and from the flash or the source. Due to high plasma opacity (the plasma emits as a near blackbody) and absorption by the molecular components of the vapor shield, the hotter core or the arc has been difficult to observe. Recent measurements along the axis or the device indicate time-averaged plasma temperatures in the barrel or about 1 eV for lower energy shots, which agree with experimental measurements of the average heat flux and plasma conductivity along the barrel. Measurements or visible emission from the source indicate time averaged temperatures of 1 to 2 eV which agree with the theoretical estimates derived from ablated mass measurements and calculated estimates derived from plasma conductivity measurements.

  20. Elevated circulating endothelial cell-derived microparticle levels in patients with liver cirrhosis: a preliminary report

    PubMed Central

    Simon, Krzysztof Adam; Pazgan-Simon, Monika

    2015-01-01

    Aim of the study To determine plausible associations between liver cirrhosis and circulating endothelial cell-derived microparticles (EMPs), vascular endothelial growth factor (VEGF) levels and plasma nitric oxide (NO) metabolites. Material and methods Sixty patients with cirrhosis and 20 healthy control subjects were enrolled in the study. Circulating EMPs from platelet-poor plasma samples were examined by flow cytometry. These microparticles were categorized into endothelial cell-derived activated MPs (EMP-ac) (CD31+ CD42b– AN-V–) and endothelial cell-derived apoptotic MPs (EMP-ap) (CD31+ CD42b– AN-V+). Plasma VEGF levels were measured by enzyme-linked immunosorbent assay. Plasma NO metabolites (NOx–) levels were determined using a Greiss reaction method. Results Compared with the healthy control subjects, the patients with cirrhosis showed a significant increase in plasma levels of both phenotypes of EMPs. When the presence of ascites was considered, the plasma levels of EMP-ap were higher (p < 0.01), as well as NOx– (p < 0.05). EMP-ap positively correlated with VEGF level in all cirrhotic patients and this correlation was stronger in decompensated cirrhotic patients. In multivariate logistic regression analysis, the independent factors associated with the presence of ascites were high EMP-ap levels and elevated VEGF levels. Conclusions Elevated plasma levels of EMP-ap in addition to high levels of VEGF might be considered as valuable parameters for predicting the occurrence of ascites in cirrhotic patients. PMID:28856256

  1. Comparison of plasma ctDNA and tissue/cytology-based techniques for the detection of EGFR mutation status in advanced NSCLC: Spanish data subset from ASSESS.

    PubMed

    Arriola, E; Paredes-Lario, A; García-Gomez, R; Diz-Tain, P; Constenla, M; García-Girón, C; Márquez, G; Reck, M; López-Vivanco, G

    2018-04-05

    The analysis of epidermal growth factor receptor (EGFR) mutations in many patients with advanced non-small-cell lung cancer (aNSCLC) has provided the opportunity for successful treatment with specific, targeted EGFR tyrosine kinase inhibitors. However, this therapeutic decision may be challenging when insufficient tumor tissue is available for EGFR mutation testing. Therefore, blood surrogate samples for EGFR mutation analysis have been suggested. Data were collected from the Spanish cohort of patients in the large, non-interventional, diagnostic ASSESS study (NCT01785888) evaluating the utility of circulating free tumor-derived DNA from plasma for EGFR mutation testing. The incidence of EGFR mutation in Spain and the level of concordance between matched tissue/cytology and plasma samples were evaluated. In a cohort of 154 eligible patients, EGFR mutations were identified in 15.1 and 11.0% of tumor and plasma samples, respectively. The most commonly used EGFR mutation testing method for the tumor tissue samples was the QIAGEN Therascreen ® EGFR RGQ PCR kit (52.1%). Fragment Length Analysis + PNA LNA Clamp was used for the plasma samples. The concordance rate for EGFR mutation status between the tissue/cytology and plasma samples was 88.8%; the sensitivity was 45.5%, and the specificity was 96.7%. The high concordance between the different DNA sources for EGFR mutation testing supports the use of plasma samples when tumor tissue is unavailable.

  2. Analytical and Clinical Validation of a Digital Sequencing Panel for Quantitative, Highly Accurate Evaluation of Cell-Free Circulating Tumor DNA

    PubMed Central

    Zill, Oliver A.; Sebisanovic, Dragan; Lopez, Rene; Blau, Sibel; Collisson, Eric A.; Divers, Stephen G.; Hoon, Dave S. B.; Kopetz, E. Scott; Lee, Jeeyun; Nikolinakos, Petros G.; Baca, Arthur M.; Kermani, Bahram G.; Eltoukhy, Helmy; Talasaz, AmirAli

    2015-01-01

    Next-generation sequencing of cell-free circulating solid tumor DNA addresses two challenges in contemporary cancer care. First this method of massively parallel and deep sequencing enables assessment of a comprehensive panel of genomic targets from a single sample, and second, it obviates the need for repeat invasive tissue biopsies. Digital SequencingTM is a novel method for high-quality sequencing of circulating tumor DNA simultaneously across a comprehensive panel of over 50 cancer-related genes with a simple blood test. Here we report the analytic and clinical validation of the gene panel. Analytic sensitivity down to 0.1% mutant allele fraction is demonstrated via serial dilution studies of known samples. Near-perfect analytic specificity (> 99.9999%) enables complete coverage of many genes without the false positives typically seen with traditional sequencing assays at mutant allele frequencies or fractions below 5%. We compared digital sequencing of plasma-derived cell-free DNA to tissue-based sequencing on 165 consecutive matched samples from five outside centers in patients with stage III-IV solid tumor cancers. Clinical sensitivity of plasma-derived NGS was 85.0%, comparable to 80.7% sensitivity for tissue. The assay success rate on 1,000 consecutive samples in clinical practice was 99.8%. Digital sequencing of plasma-derived DNA is indicated in advanced cancer patients to prevent repeated invasive biopsies when the initial biopsy is inadequate, unobtainable for genomic testing, or uninformative, or when the patient’s cancer has progressed despite treatment. Its clinical utility is derived from reduction in the costs, complications and delays associated with invasive tissue biopsies for genomic testing. PMID:26474073

  3. Laser ablation inductively coupled plasma mass spectrometry measurement of isotope ratios in depleted uranium contaminated soils.

    PubMed

    Seltzer, Michael D

    2003-09-01

    Laser ablation of pressed soil pellets was examined as a means of direct sample introduction to enable inductively coupled plasma mass spectrometry (ICP-MS) screening of soils for residual depleted uranium (DU) contamination. Differentiation between depleted uranium, an anthropogenic contaminant, and naturally occurring uranium was accomplished on the basis of measured 235U/238U isotope ratios. The amount of sample preparation required for laser ablation is considerably less than that typically required for aqueous sample introduction. The amount of hazardous laboratory waste generated is diminished accordingly. During the present investigation, 235U/238U isotope ratios measured for field samples were in good agreement with those derived from gamma spectrometry measurements. However, substantial compensation was required to mitigate the effects of impaired pulse counting attributed to sample inhomogeneity and sporadic introduction of uranium analyte into the plasma.

  4. Analysis of methyloxime derivatives of intact esters of testosterone and boldenone in equine plasma using ultra high performance liquid chromatography tandem mass spectrometry.

    PubMed

    Gray, Bobby P; Teale, Phil; Pearce, Clive M

    2011-04-01

    Analysis of equine plasma samples to detect the abuse of anabolic steroids can be complicated when the parent steroid is endogenous to the animal. Anabolic steroids are usually administered intramuscularly as synthetic esters and therefore detection of the exogenous esters provides unequivocal proof of illegal administration. An ultra high performance liquid chromatography tandem mass spectrometric (UPLC-MSMS) method for the analysis of esters of testosterone (propionate, phenylpropionate, isocaproate, and decanoate) and boldenone (undecylenate) in equine plasma has been developed. Esters were extracted from equine plasma using a mixture of hexane and ethyl acetate and treated with methoxyamine hydrochloride to form methyloxime derivatives. Metenolone enanthate was used as an internal standard. After chromatographic separation, the derivatized steroid esters were quantified using selected reaction monitoring (SRM). The limit of detection for all of the steroid esters, based on a signal to noise ratio (S/N) of 3:1, was 1-3 pg/mL. The lower limit of quantification (LLOQ) for the all of the steroid esters was 5 pg/mL when 2 mL of plasma was extracted. Recovery of the steroid esters was 85-97% for all esters except for testosterone decanoate which was recovered at 62%. The intra-day coefficient of variation (CV) for the analysis of plasma quality control (QC) samples was less than 9.2% at 40 pg/mL and less than 6.0% at 400 pg/mL. The developed assay was used to successfully confirm the presence of intact testosterone esters in equine plasma samples following intramuscular injection of Durateston® (mixed testosterone esters). Copyright © 2011 John Wiley & Sons, Ltd.

  5. One mouse, one pharmacokinetic profile: quantitative whole blood serial sampling for biotherapeutics.

    PubMed

    Joyce, Alison P; Wang, Mengmeng; Lawrence-Henderson, Rosemary; Filliettaz, Cynthia; Leung, Sheldon S; Xu, Xin; O'Hara, Denise M

    2014-07-01

    The purpose of this study was to validate the approach of serial sampling from one mouse through ligand binding assay (LBA) quantification of dosed biotherapeutic in diluted whole blood to derive a pharmacokinetic (PK) profile. This investigation compared PK parameters obtained using serial and composite sampling methods following administration of human IgG monoclonal antibody. The serial sampling technique was established by collecting 10 μL of blood via tail vein at each time point following drug administration. Blood was immediately diluted into buffer followed by analyte quantitation using Gyrolab to derive plasma concentrations. Additional studies were conducted to understand matrix and sampling site effects on drug concentrations. The drug concentration profiles, irrespective of biological matrix, and PK parameters using both sampling methods were not significantly different. There were no sampling site effects on drug concentration measurements except that concentrations were slightly lower in sodium citrated plasma than other matrices. We recommend the application of mouse serial sampling, particularly with limiting drug supply or specialized animal models. Overall the efficiencies gained by serial sampling were 40-80% savings in study cost, animal usage, study length and drug conservation while inter-subject variability across PK parameters was less than 30%.

  6. Evaluation of microextraction by packed sorbent, liquid-liquid microextraction and derivatization pretreatment of diet-derived phenolic acids in plasma by gas chromatography with triple quadrupole mass spectrometry.

    PubMed

    Bustamante, Luis; Cárdenas, Diana; von Baer, Dietrich; Pastene, Edgar; Duran-Sandoval, Daniel; Vergara, Carola; Mardones, Claudia

    2017-09-01

    Miniaturized sample pretreatments for the analysis of phenolic metabolites in plasma, involving protein precipitation, enzymatic deconjugation, extraction procedures, and different derivatization reactions were systematically evaluated. The analyses were conducted by gas chromatography with mass spectrometry for the evaluation of 40 diet-derived phenolic compounds. Enzyme purification was necessary for the phenolic deconjugation before extraction. Trimethylsilanization reagent and two different tetrabutylammonium salts for derivatization reactions were compared. The optimum reaction conditions were 50 μL of trimethylsilanization reagent at 90°C for 30 min, while tetrabutylammonium salts were associated with loss of sensitivity due to rapid activation of the inert gas chromatograph liner. Phenolic acids extractions from plasma were optimized. Optimal microextraction by packed sorbent performance was achieved using an octadecylsilyl packed bed and better recoveries for less polar compounds, such as methoxylated derivatives, were observed. Despite the low recovery for many analytes, repeatability using an automated extraction procedure in the gas chromatograph inlet was 2.5%. Instead, using liquid-liquid microextraction, better recoveries (80-110%) for all analytes were observed at the expense of repeatability (3.8-18.4%). The phenolic compounds in gerbil plasma samples, collected before and 4 h after the administration of a calafate extract, were analyzed with the optimized methodology. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. Comparison of cross-sectional HIV incidence assay results from dried blood spots and plasma.

    PubMed

    Schlusser, Katherine E; Pilcher, Christopher; Kallas, Esper G; Santos, Breno R; Deeks, Steven G; Facente, Shelley; Keating, Sheila M; Busch, Michael P; Murphy, Gary; Welte, Alex; Quinn, Thomas; Eshleman, Susan H; Laeyendecker, Oliver

    2017-01-01

    Assays have been developed for cross-sectional HIV incidence estimation using plasma samples. Large scale surveillance programs are planned using dried blood spot (DBS) specimens for incidence assessment. However, limited information exists on the performance of HIV cross-sectional incidence assays using DBS. The assays evaluated were: Maxim HIV-1 Limiting Antigen Avidity EIA (LAg-Avidity), Sedia HIV-1 BED-Capture EIA (BED-CEIA), and CDC modified BioRad HIV-1/2 Plus O Avidity-based Assay (CDC-BioRad Avidity) using pre-determined cutoff values. 100 matched HIV-1 positive plasma and DBS samples, with known duration of infection, from the Consortium for the Evaluation and Performance of HIV Incidence Assays repository were tested. All assays were run in duplicate. To examine the degree of variability within and between results for each sample type, both categorical and continuous results were analyzed. Associations were assessed with Bland Altman, R2 values and Cohen's kappa coefficient (ĸ). Intra-assay variability using the same sample type was similar for all assays (R2 0.96 to 1.00). The R2 values comparing DBS and plasma results for LAg-Avidity, BED-CEIA, and CDC-BioRad Avidity were 0.96, 0.94, and 0.84, respectively. The concordance and ĸ values between DBS and plasma for all three assays were >87% and >0.64, respectively. The Bland-Altman analysis showed significant differences between plasma and DBS samples. For all three assays, a higher number of samples were classified as recent infections using DBS samples. DBS and plasma sample results were highly correlated. However, when compared to plasma, each assay performed somewhat differently in DBS at the lower and higher ends of the dynamic range. DBS samples were more likely to be classified as recently infected by all three assays, which may lead to overestimation of incidence in surveys using performance criteria derived for plasma samples.

  8. Rapid solid-phase immunoassay for 6-keto prostaglandin F1 alpha on microplates

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schramm, W.; Smith, R.H.; Jackson, T.M.

    1990-03-01

    We describe, for the measurement of 6-keto prostaglandin F1 alpha in biological media, a solid-phase immunoassay with immobilized antibodies that requires a total processing time of less than 2 h with hands-on time less than 30 min for 40 samples. The method combines the convenience of the microplate format with the sensitivity of radiolabeled prostaglandin derivatives as tracers in a competitive immunoassay. The intra- and interassay variations at 50% displacement of the radiolabeled prostaglandin derivative as tracer were 9.0% and 11.8%, respectively. At 50% displacement of the radiolabeled tracer, the sensitivity is about 20 pg per well. Optimal incubation timemore » is between 60 and 90 min. Nonspecific binding was less than 1% if about 8 pg of tracer (approximately 25,000 counts/min per well) was used. Inhibition curves of samples in different dilutions were parallel to standard curves. The variation of bound radiolabeled prostaglandin derivative within the wells of one microplate (n = 96) was less than 3%. Human plasma samples and medium from tissue culture assayed for 6-keto prostaglandin F1 alpha correlated well with results obtained with a solid-phase assay based on use of magnetic particles (r = 0.99, n = 24) for culture-medium samples; r = 0.99; n = 26 for plasma samples.« less

  9. Development of a lectin binding assay to differentiate between recombinant and endogenous proteins in pharmacokinetic studies of protein-biopharmaceuticals.

    PubMed

    Weber, Alfred; Minibeck, Eva; Scheiflinger, Friedrich; Turecek, Peter L

    2015-04-10

    Human glycoproteins, expressed in hamster cell lines, show similar glycosylation patterns to naturally occurring human molecules except for a minute difference in the linkage of terminal sialic acid: both cell types lack α2,6-galactosyl-sialyltransferase, abundantly expressed in human hepatocytes and responsible for the α2,6-sialylation of circulating glycoproteins. This minute difference, which is currently not known to have any physiological relevance, was the basis for the selective measurement of recombinant glycoproteins in the presence of their endogenous counterparts. The assay is based on using the lectin Sambucus nigra agglutinin (SNA), selectively binding to α2,6-sialylated N-glycans. Using von Willebrand factor (VWF), factor IX (FIX), and factor VIIa (FVIIa), it was demonstrated that (i) the plasma-derived proteins, but not the corresponding recombinant proteins, specifically bind to SNA and (ii) this binding can be used to deplete the plasma-derived proteins. The feasibility of this approach was confirmed in spike-recovery studies for all three recombinant coagulation proteins in human plasma and for recombinant VWF (rVWF) in macaque plasma. Analysis of plasma samples from macaques after administration of recombinant and a plasma-derived VWF demonstrated the suitability and robustness of this approach. Data showed that rVWF could be selectively measured without changing the ELISAs and furthermore revealed the limitations of baseline adjustment using a single measurement of the predose concentration only. The SNA gel-based depletion procedure can easily be integrated in existing procedures as a specific sample pre-treatment step. While ELISA-based methods were used to measure the recombinant coagulation proteins in the supernatants obtained by depletion, this procedure is applicable for all biochemical analyses. Copyright © 2015 Elsevier B.V. All rights reserved.

  10. High performance liquid chromatography with UV detection for the simultaneous determination of sympathomimetic amines using 4-(4,5-diphenyl-1H-imidazole-2-yl)benzoyl chloride as a label.

    PubMed

    Kaddoumi, A; Kubota, A; Nakashima, M N; Takahashi, M; Nakashima, K

    2001-10-01

    A high performance liquid chromatographic method has been developed for the simultaneous determination of (+/-) fenfluramine (Fen) and phentermine (Phen) in addition to three other sympathomimetic amines-ephedrine (E), norephedrine (NE) and 2-phenylethylamine (2-PEA), using cyclohexylamine (CX) as an internal standard in plasma. The compounds were derivatized with 4-(4,5-diphenyl-1H-imidazole-2-yl)benzoyl chloride (DIB-Cl) to give the DIB-derivatives. The derivatives were then separated using an isocratic HPLC system with UV detection. The limits of detection for Fen, Phen, E, NE and 2-PEA in plasma ranged from 0.32 to 22.9 pmol on column at a signal-to-noise ratio of 3. The recoveries following alkaline extraction from plasma samples of known concentrations were found to be more than 94% for the studied compounds. This method might be useful for the screening of the studied sympathomimetic amines in human plasma samples in forensic as well as toxicological studies. Furthermore, the developed method was modified for the simultaneous determination of Fen and Phen in human and rat plasma using fluoxetine as an internal standard. The methods are reproducible and precise. Finally, the two drugs were administered intraperitoneally to rats in combination, and their plasma levels over the investigated time course were successfully determined. Copyright 2001 John Wiley & Sons, Ltd.

  11. Powder Metallurgy Processing of a WxTaTiVCr High-Entropy Alloy and Its Derivative Alloys for Fusion Material Applications.

    PubMed

    Waseem, Owais Ahmed; Ryu, Ho Jin

    2017-05-16

    The W x TaTiVCr high-entropy alloy with 32at.% of tungsten (W) and its derivative alloys with 42 to 90at.% of W with in-situ TiC were prepared via the mixing of elemental W, Ta, Ti, V and Cr powders followed by spark plasma sintering for the development of reduced-activation alloys for fusion plasma-facing materials. Characterization of the sintered samples revealed a BCC lattice and a multi-phase structure. The selected-area diffraction patterns confirmed the formation of TiC in the high-entropy alloy and its derivative alloys. It revealed the development of C15 (cubic) Laves phases as well in alloys with 71 to 90at.% W. A mechanical examination of the samples revealed a more than twofold improvement in the hardness and strength due to solid-solution strengthening and dispersion strengthening. This study explored the potential of powder metallurgy processing for the fabrication of a high-entropy alloy and other derived compositions with enhanced hardness and strength.

  12. Comparison of Human Immunodeficiency Virus Type 1 Tropism Profiles in Clinical Samples by the Trofile and MT-2 Assays▿

    PubMed Central

    Coakley, Eoin; Reeves, Jacqueline D.; Huang, Wei; Mangas-Ruiz, Marga; Maurer, Irma; Harskamp, Agnes M.; Gupta, Soumi; Lie, Yolanda; Petropoulos, Christos J.; Schuitemaker, Hanneke; van 't Wout, Angélique B.

    2009-01-01

    The recent availability of CCR5 antagonists as anti-human immunodeficiency virus (anti-HIV) therapeutics has highlighted the need to accurately identify CXCR4-using variants in patient samples when use of this new drug class is considered. The Trofile assay (Monogram Biosciences) has become the method that is the most widely used to define tropism in the clinic prior to the use of a CCR5 antagonist. By comparison, the MT-2 assay has been used since early in the HIV epidemic to define tropism in clinical specimens. Given that there are few data from direct comparisons of these two assays, we evaluated the performance of the plasma-based Trofile assay and the peripheral blood mononuclear cell (PBMC)-based MT-2 assay for the detection of CXCR4 use in defining the tropism of HIV isolates derived from clinical samples. The various samples used for this comparison were derived from participants of the Amsterdam Cohort Studies on HIV infection and AIDS who underwent consecutive MT-2 assay testing of their PBMCs at approximately 3-month intervals. This unique sample set was specifically selected because consecutive MT-2 assays had demonstrated a shift from negative to positive in PBMCs, reflecting the first emergence of CXCR4-using virus in PBMCs above the level of detection of the assay in these individuals. Trofile testing was performed with clonal HIV type 1 (HIV-1) variants (n = 21), MT-2 cell culture-derived cells (n = 20) and supernatants (n = 42), and plasma samples (n = 76). Among the clonal HIV-1 variants and MT-2 cell culture-derived samples, the results of the Trofile and MT-2 assays demonstrated a high degree of concordance (95% to 98%). Among consecutive plasma samples, detection of CXCR4-using virus was at or before the time of first detection by the MT-2 assay in 5/10 patients by the original Trofile assay and in 9/10 patients by the enhanced-sensitivity Trofile assay. Differences in the time to the first detection of CXCR4 use between the MT-2 assay (PBMCs) and the original Trofile assay (plasma) were greatly reduced by the enhanced-sensitivity Trofile assay, suggesting that sensitivity for the detection of minor CXCR4-using variants may be a more important determinant of discordant findings than compartmentalization. The similarities in performance of the enhanced-sensitivity Trofile and MT-2 assays suggest that either may be an appropriate methodology to define tropism in patient specimens. PMID:19687240

  13. Comparison of human immunodeficiency virus type 1 tropism profiles in clinical samples by the Trofile and MT-2 assays.

    PubMed

    Coakley, Eoin; Reeves, Jacqueline D; Huang, Wei; Mangas-Ruiz, Marga; Maurer, Irma; Harskamp, Agnes M; Gupta, Soumi; Lie, Yolanda; Petropoulos, Christos J; Schuitemaker, Hanneke; van 't Wout, Angélique B

    2009-11-01

    The recent availability of CCR5 antagonists as anti-human immunodeficiency virus (anti-HIV) therapeutics has highlighted the need to accurately identify CXCR4-using variants in patient samples when use of this new drug class is considered. The Trofile assay (Monogram Biosciences) has become the method that is the most widely used to define tropism in the clinic prior to the use of a CCR5 antagonist. By comparison, the MT-2 assay has been used since early in the HIV epidemic to define tropism in clinical specimens. Given that there are few data from direct comparisons of these two assays, we evaluated the performance of the plasma-based Trofile assay and the peripheral blood mononuclear cell (PBMC)-based MT-2 assay for the detection of CXCR4 use in defining the tropism of HIV isolates derived from clinical samples. The various samples used for this comparison were derived from participants of the Amsterdam Cohort Studies on HIV infection and AIDS who underwent consecutive MT-2 assay testing of their PBMCs at approximately 3-month intervals. This unique sample set was specifically selected because consecutive MT-2 assays had demonstrated a shift from negative to positive in PBMCs, reflecting the first emergence of CXCR4-using virus in PBMCs above the level of detection of the assay in these individuals. Trofile testing was performed with clonal HIV type 1 (HIV-1) variants (n = 21), MT-2 cell culture-derived cells (n = 20) and supernatants (n = 42), and plasma samples (n = 76). Among the clonal HIV-1 variants and MT-2 cell culture-derived samples, the results of the Trofile and MT-2 assays demonstrated a high degree of concordance (95% to 98%). Among consecutive plasma samples, detection of CXCR4-using virus was at or before the time of first detection by the MT-2 assay in 5/10 patients by the original Trofile assay and in 9/10 patients by the enhanced-sensitivity Trofile assay. Differences in the time to the first detection of CXCR4 use between the MT-2 assay (PBMCs) and the original Trofile assay (plasma) were greatly reduced by the enhanced-sensitivity Trofile assay, suggesting that sensitivity for the detection of minor CXCR4-using variants may be a more important determinant of discordant findings than compartmentalization. The similarities in performance of the enhanced-sensitivity Trofile and MT-2 assays suggest that either may be an appropriate methodology to define tropism in patient specimens.

  14. Increased serum concentration of immune cell derived microparticles in polymyositis/dermatomyositis.

    PubMed

    Baka, Zsuzsanna; Senolt, Ladislav; Vencovsky, Jiri; Mann, Herman; Simon, Piroska Sebestyén; Kittel, Agnes; Buzás, Edit; Nagy, György

    2010-02-16

    Microparticles are recently recognized players of intercellular communication. They are involved in signal transduction, cell activation and apoptosis. Their importance is also suggested in autoimmune diseases such as rheumatoid arthritis and systemic sclerosis. We investigated the role of microparticles in polymyositis/dermatomyositis, a group of rare autoimmune diseases, characterized by specific skin lesions and muscle weakness. The plasma concentration of monocyte and lymphocyte derived microparticles of 20 patients with polymyositis/dermatomyositis and 20 healthy controls were determined by flow cytometry. The structure of microparticles was visualized by electron microscopy. Significantly elevated numbers of monocyte (CD14 positive), T-lymphocyte (CD3 positive) and B-lymphocyte (CD19 positive) derived microparticles were found in the plasma samples of polymyositis/dermatomyositis patients, compared to healthy controls (p=0.001, 0.01 and 0.006, respectively). Furthermore, the plasma levels of monocyte and B-lymphocyte derived microparticles correlated with the manual muscle strength test (r=0.497, p=0.027; r=0.508, p=0.023; respectively). Patients with anti-Jo-1 antibody and lung involvement had significantly higher numbers of T- and B-lymphocyte and monocyte derived MPs (p=0.006, 0.012 and 0.007, respectively, for anti-Jo-1; p=0.013, 0.016 and 0.025, respectively, for lung involvement). After ultracentrifugation, CK activity could be detected only in traces in the resuspended pellet containing microparticles of healthy and diseased individuals. The electron microscopy revealed slightly different microparticles in the samples of patients with polymyositis/dermatomyositis. These results suggest that immune cell derived microparticles may contribute to the inflammatory process in polymyositis/dermatomyositis, however, CK-positive, possibly muscle derived microparticles do not seem to be present in the blood of patients with polymyositis/dermatomyositis. Copyright (c) 2010 Elsevier B.V. All rights reserved.

  15. Automated determination of polyamines by high-performance liquid chromatography with simple sample preparation.

    PubMed

    van Eijk, H M; Rooyakkers, D R; Deutz, N E

    1996-04-12

    Recently, a new fully endcapped reversed-phase packing material, Inertsil, was introduced, especially suitable for the determination of basic compounds. We used this packing material to separate ophthaldialdehyde (OPA) derivatives of amino acid derivatives completely from the OPA derivatives of spermine (SPM), spermidine (SPD), putrescine (PUT) and cadaverine (CAD). The obtained separation made the commonly used off-line extraction procedure redundant and thus an on-line sample clean-up was introduced. This enabled automation of the procedure resulting in a better reproducibility and a more efficient use of equipment. Furthermore, no studies are required to determine the extraction recovery. The present method has a cycle time of 30 min. A linear response for each polyamine was found up to 250 pmol, with an R2 ranging from 0.9981 (SPM) to 0.9998 (CAD). The limit of detection, calculated at a signal-to-noise ratio of 3, was 0.1 pmol, corresponding to a plasma concentration of 0.1 mumol/l. The coefficient of variation (C.V.) for the peak area was below 3% and for retention times below 0.5% (n = 15). In order to evaluate the applicability of the method, three different types of sample were chromatographed, e.g. urine (obtained from healthy human volunteers), pig plasma and sulfosalicylic acid homogenates of pig intestine biopsies. Tissue homogenates and urine-specimen could easily be quantitated, while plasma concentrations were just above the limit of detection, resulting in a plasma C.V. ranging from 4.8% (SPM) to 13.6% (SPD) and a tissue C.V. ranging from 2.1% (SPM) to 8.5% (CAD), The urinary C.V.s were not determined. In conclusion, the present method provides an easy way to measure polyamine concentrations for most applications.

  16. Stability of BDNF in Human Samples Stored Up to 6 Months and Correlations of Serum and EDTA-Plasma Concentrations.

    PubMed

    Polyakova, Maryna; Schlögl, Haiko; Sacher, Julia; Schmidt-Kassow, Maren; Kaiser, Jochen; Stumvoll, Michael; Kratzsch, Jürgen; Schroeter, Matthias L

    2017-06-03

    Brain-derived neurotrophic factor (BDNF), an important neural growth factor, has gained growing interest in neuroscience, but many influencing physiological and analytical aspects still remain unclear. In this study we assessed the impact of storage time at room temperature, repeated freeze/thaw cycles, and storage at -80 °C up to 6 months on serum and ethylenediaminetetraacetic acid (EDTA)-plasma BDNF. Furthermore, we assessed correlations of serum and plasma BDNF concentrations in two independent sets of samples. Coefficients of variations (CVs) for serum BDNF concentrations were significantly lower than CVs of plasma concentrations ( n = 245, p = 0.006). Mean serum and plasma concentrations at all analyzed time points remained within the acceptable change limit of the inter-assay precision as declared by the manufacturer. Serum and plasma BDNF concentrations correlated positively in both sets of samples and at all analyzed time points of the stability assessment ( r = 0.455 to r s = 0.596; p < 0.004). In summary, when considering the acceptable change limit, BDNF was stable in serum and in EDTA-plasma up to 6 months. Due to a higher reliability, we suggest favoring serum over EDTA-plasma for future experiments assessing peripheral BDNF concentrations.

  17. ctDNA Determination of EGFR Mutation Status in European and Japanese Patients with Advanced NSCLC: The ASSESS Study.

    PubMed

    Reck, Martin; Hagiwara, Koichi; Han, Baohui; Tjulandin, Sergei; Grohé, Christian; Yokoi, Takashi; Morabito, Alessandro; Novello, Silvia; Arriola, Edurne; Molinier, Olivier; McCormack, Rose; Ratcliffe, Marianne; Normanno, Nicola

    2016-10-01

    To offer patients with EGFR mutation-positive advanced NSCLC appropriate EGFR tyrosine kinase inhibitor treatment, mutation testing of tumor samples is required. However, tissue/cytologic samples are not always available or evaluable. The large, noninterventional diagnostic ASSESS study (NCT01785888) evaluated the utility of circulating free tumor-derived DNA (ctDNA) from plasma for EGFR mutation testing. ASSESS was conducted in 56 centers (in Europe and Japan). Eligible patients (with newly diagnosed locally advanced/metastatic treatment-naive advanced NSCLC) provided diagnostic tissue/cytologic and plasma samples. DNA extracted from tissue/cytologic samples was subjected to EGFR mutation testing using local practices; designated laboratories performed DNA extraction/mutation testing of blood samples. The primary end point was level of concordance of EGFR mutation status between matched tissue/cytologic and plasma samples. Of 1311 patients enrolled, 1288 were eligible. Concordance of mutation status in 1162 matched samples was 89% (sensitivity 46%, specificity 97%, positive predictive value 78%, and negative predictive value 90%). A group of 25 patients with apparent false-positive plasma results was overrepresented for cytologic samples, use of less sensitive tissue testing methodologies, and smoking habits associated with high EGFR mutation frequency, indicative of false-negative tumor results. In cases in which plasma and tumor samples were tested with identical highly sensitive methods, positive predictive value/sensitivity were generally improved. These real-world data suggest that ctDNA is a feasible sample for EGFR mutation analysis. It is important to conduct mutation testing of both tumor and plasma samples in specialized laboratories, using robust/sensitive methods to ensure that patients receive appropriate treatments that target the molecular features of their disease. Copyright © 2016 International Association for the Study of Lung Cancer. Published by Elsevier Inc. All rights reserved.

  18. Which is safer source plasma for manufacturing in China: apheresis plasma or recovered plasma?

    PubMed

    Liu, Yu; Li, Changqing; Wang, Ya; Zhang, Yan; Wu, Binting; Ke, Ling; Xu, Min; Liu, Gui; Liu, Zhong

    2016-05-01

    In most countries, the plasma for derivative production includes two types of plasma, apheresis plasma (AP) and recovered plasma (RP). However, the plasma recovered from whole blood is not permitted for manufacture in China. Because of the lack of source plasma and the surplus of RP, the Chinese government is considering allowing RP as an equivalent source for the production of plasma derivatives. It is known that human blood can be contaminated by various infectious agents. The objective of the study was to evaluate if infectious risk would increase by enacting this policy. The samples from the two types of blood donors from January 1 to December 31, 2013, were collected. Supplementary testing was conducted and the residual risk (RR) of human immunodeficiency virus (HIV), hepatitis B virus, and hepatitis C virus (HCV) in the two types of blood donors and donations were calculated through the incidence-window period model. Prevalence of the markers of hepatitis E virus, hepatitis A virus, severe fever with thrombocytopenia syndrome bunyavirus, cytomegalovirus, B19, and West Nile virus was calculated. No significant difference was found in the RR of the three pathogens in the two types of blood donors. However, after the quarantine period, the RR of HCV and HIV in AP was significantly lower than that in RP. A quarantine period of 2 years will make the infectious risk of RP not significantly different than that of AP. Our data demonstrate that allowing RP to be used for the manufacture of plasma derivatives will not increase its infectious disease risk if coupled with a 2-year inventory hold. © 2016 AABB.

  19. IMPROVED DERIVATION OF INPUT FUNCTION IN DYNAMIC MOUSE [18F]FDG PET USING BLADDER RADIOACTIVITY KINETICS

    PubMed Central

    Wong, Koon-Pong; Zhang, Xiaoli; Huang, Sung-Cheng

    2013-01-01

    Purpose Accurate determination of the plasma input function (IF) is essential for absolute quantification of physiological parameters in positron emission tomography (PET). However, it requires an invasive and tedious procedure of arterial blood sampling that is challenging in mice because of the limited blood volume. In this study, a hybrid modeling approach is proposed to estimate the plasma IF of 2-deoxy-2-[18F]fluoro-D-glucose ([18F]FDG) in mice using accumulated radioactivity in urinary bladder together with a single late-time blood sample measurement. Methods Dynamic PET scans were performed on nine isoflurane-anesthetized male C57BL/6 mice after a bolus injection of [18F]FDG at the lateral caudal vein. During a 60- or 90-min scan, serial blood samples were taken from the femoral artery. Image data were reconstructed using filtered backprojection with CT-based attenuation correction. Total accumulated radioactivity in the urinary bladder was fitted to a renal compartmental model with the last blood sample and a 1-exponential function that described the [18F]FDG clearance in blood. Multiple late-time blood sample estimates were calculated by the blood [18F]FDG clearance equation. A sum of 4-exponentials was assumed for the plasma IF that served as a forcing function to all tissues. The estimated plasma IF was obtained by simultaneously fitting the [18F]FDG model to the time-activity curves (TACs) of liver and muscle and the forcing function to early (0–1 min) left-ventricle data (corrected for delay, dispersion, partial-volume effects and erythrocytes uptake) and the late-time blood estimates. Using only the blood sample acquired at the end of the study to estimate the IF and the use of liver TAC as an alternative IF were also investigated. Results The area under the plasma TACs calculated for all studies using the hybrid approach was not significantly different from that using all blood samples. [18F]FDG uptake constants in brain, myocardium, skeletal muscle and liver computed by the Patlak analysis using estimated and measured plasma TACs were in excellent agreement (slope ~ 1; R2 > 0.938). The IF estimated using only the last blood sample acquired at the end of the study and the use of liver TAC as plasma IF provided less reliable results. Conclusions The estimated plasma IFs obtained with the hybrid model agreed well with those derived from arterial blood sampling. Importantly, the proposed method obviates the need of arterial catheterization, making it possible to perform repeated dynamic [18F]FDG PET studies on the same animal. Liver TAC is unsuitable as an input function for absolute quantification of [18F]FDG PET data. PMID:23322346

  20. Presence of Donor-Derived DNA in Semen Samples From Cancer Survivors Who Underwent Donor Stem Cell Transplant

    ClinicalTrials.gov

    2014-12-08

    Cancer Survivor; Chronic Myeloproliferative Disorders; Leukemia; Lymphoma; Multiple Myeloma and Plasma Cell Neoplasm; Myelodysplastic Syndromes; Myelodysplastic/Myeloproliferative Neoplasms; Neuroblastoma; Testicular Germ Cell Tumor

  1. Frequent Cross-Resistance to Dapivirine in HIV-1 Subtype C-Infected Individuals after First-Line Antiretroviral Therapy Failure in South Africa.

    PubMed

    Penrose, Kerri J; Wallis, Carole L; Brumme, Chanson J; Hamanishi, Kristen A; Gordon, Kelley C; Viana, Raquel V; Harrigan, P Richard; Mellors, John W; Parikh, Urvi M

    2017-02-01

    A vaginal ring containing dapivirine (DPV) has shown moderate protective efficacy against HIV-1 acquisition, but the activity of DPV against efavirenz (EFV)- and nevirapine (NVP)-resistant viruses that could be transmitted is not well defined. We investigated DPV cross-resistance of subtype C HIV-1 from individuals on failing NVP- or EFV-containing antiretroviral therapy (ART) in South Africa. Plasma samples were obtained from individuals with >10,000 copies of HIV RNA/ml and with HIV-1 containing at least one non-nucleoside reverse transcriptase (NNRTI) mutation. Susceptibility to NVP, EFV, and DPV in TZM-bl cells was determined for recombinant HIV-1 LAI containing bulk-amplified, plasma-derived, full-length reverse transcriptase sequences. Fold change (FC) values were calculated compared with a composite 50% inhibitory concentration (IC 50 ) from 12 recombinant subtype C HIV-1 LAI plasma-derived viruses from treatment-naive individuals in South Africa. A total of 25/100 (25%) samples showed >500-FCs to DPV compared to treatment-naive samples with IC 50 s exceeding the maximum DPV concentration tested (132 ng/ml). A total of 66/100 (66%) samples displayed 3- to 306-FCs, with a median IC 50 of 17.6 ng/ml. Only 9/100 (9%) samples were susceptible to DPV (FC < 3). Mutations L100I and K103N were significantly more frequent in samples with >500-fold resistance to DPV compared to samples with a ≤500-fold resistance. A total of 91% of samples with NNRTI-resistant HIV-1 from individuals on failing first-line ART in South Africa exhibited ≥3-fold cross-resistance to DPV. This level of resistance exceeds expected plasma concentrations, but very high genital tract DPV concentrations from DPV ring use could block viral replication. It is critically important to assess the frequency of transmitted and selected DPV resistance in individuals using the DPV ring. Copyright © 2017 American Society for Microbiology.

  2. Frequent Cross-Resistance to Dapivirine in HIV-1 Subtype C-Infected Individuals after First-Line Antiretroviral Therapy Failure in South Africa

    PubMed Central

    Penrose, Kerri J.; Wallis, Carole L.; Brumme, Chanson J.; Hamanishi, Kristen A.; Gordon, Kelley C.; Viana, Raquel V.; Harrigan, P. Richard; Mellors, John W.

    2016-01-01

    ABSTRACT A vaginal ring containing dapivirine (DPV) has shown moderate protective efficacy against HIV-1 acquisition, but the activity of DPV against efavirenz (EFV)- and nevirapine (NVP)-resistant viruses that could be transmitted is not well defined. We investigated DPV cross-resistance of subtype C HIV-1 from individuals on failing NVP- or EFV-containing antiretroviral therapy (ART) in South Africa. Plasma samples were obtained from individuals with >10,000 copies of HIV RNA/ml and with HIV-1 containing at least one non-nucleoside reverse transcriptase (NNRTI) mutation. Susceptibility to NVP, EFV, and DPV in TZM-bl cells was determined for recombinant HIV-1LAI containing bulk-amplified, plasma-derived, full-length reverse transcriptase sequences. Fold change (FC) values were calculated compared with a composite 50% inhibitory concentration (IC50) from 12 recombinant subtype C HIV-1LAI plasma-derived viruses from treatment-naive individuals in South Africa. A total of 25/100 (25%) samples showed >500-FCs to DPV compared to treatment-naive samples with IC50s exceeding the maximum DPV concentration tested (132 ng/ml). A total of 66/100 (66%) samples displayed 3- to 306-FCs, with a median IC50 of 17.6 ng/ml. Only 9/100 (9%) samples were susceptible to DPV (FC < 3). Mutations L100I and K103N were significantly more frequent in samples with >500-fold resistance to DPV compared to samples with a ≤500-fold resistance. A total of 91% of samples with NNRTI-resistant HIV-1 from individuals on failing first-line ART in South Africa exhibited ≥3-fold cross-resistance to DPV. This level of resistance exceeds expected plasma concentrations, but very high genital tract DPV concentrations from DPV ring use could block viral replication. It is critically important to assess the frequency of transmitted and selected DPV resistance in individuals using the DPV ring. PMID:27895013

  3. Rapid measurement of fibrinogen concentration in whole blood using a steel ball coagulometer

    PubMed Central

    Schlimp, Christoph J.; Khadem, Anna; Klotz, Anton; Solomon, Cristina; Hochleitner, Gerald; Ponschab, Martin; Redl, Heinz; Schöchl, Herbert

    2015-01-01

    BACKGROUND Fibrinogen plays a key role in hemostasis and is the first coagulation factor to reach critical levels in bleeding patients. Current European guidelines on the management of traumatic or perioperative bleeding recommend fibrinogen supplementation at specific threshold levels. Whole blood viscoelastic tests provide fast evaluation of fibrin deficits. Fast measurement of plasma fibrinogen concentration is not yet available. We investigated a method to rapidly determine whole blood fibrinogen concentration using standard Clauss assays and a steel ball coagulometer and provide an estimate of the “plasma-equivalent” fibrinogen concentration within minutes by adjustment of the measured whole blood fibrinogen concentration with a quickly measureable hemoglobin-derived hematocrit. METHODS The feasibility of this approach was tested with a Clauss assay using multiple porcine fresh blood samples obtained during in vivo bleeding, hemodilution, and after treatment with hemostatic therapy. Two different Clauss assays were then tested using multiple human volunteers’ blood samples diluted in vitro and supplemented with fibrinogen concentrate. Comparative measurements with fibrin-based thromboelastometry tests were performed. RESULTS Regression and Bland-Altman analyses of derived “plasma-equivalent” fibrinogen and measured plasma fibrinogen concentration was excellent in porcine and human blood samples, especially in the ranges relevant to traumatic or perioperative bleeding. CONCLUSION Fast whole blood fibrinogen measurements could be considered as an alternative to plasma fibrinogen measurement for acute bleeding management in trauma and perioperative care settings. Further studies are needed to prove this concept and determine the turnaround times for its clinical application in emergency departments and operating theaters. PMID:25742256

  4. Universal immunization of infants with low doses of a low-cost, plasma-derived hepatitis B vaccine in South Africa.

    PubMed Central

    Schoub, B. D.; Matai, U.; Singh, B.; Blackburn, N. K.; Levin, J. B.

    2002-01-01

    OBJECTIVE: To evaluate the effectiveness of universal vaccination against viral hepatitis B in South Africa among 18-month-old rural children. METHODS: Children were immunized with a course of low-dose (1.5 microg), plasma-derived hepatitis B vaccine at 6, 10 and 14 weeks of age, and blood samples from the children were tested for three hepatitis B markers: hepatitis B surface antigen (HBsAg), anti-HBs and anti-HBc. FINDINGS: One year after vaccination, a protective anti-HBs antibody titre of at least 10 IU/l was present in 669/769 (87.0%) of blood serum samples tested. Only 3/756 children (0.4%) were HBsAg positive and a fourth child was anti-HBc positive (HBsAg negative). This is a marked decrease compared to the hepatitis B prevalences reported in previous studies. Among rural migrant mine-workers, for example, HBsAg prevalence was 9.9%, and was 10.1% among children 0-6 years of age in the Eastern Cape Province. CONCLUSION: The low-dose, plasma-derived hepatitis B vaccine, which is affordable to most developing countries, was very successful in controlling endemic hepatitis B infection, where the virus is predominantly spread by horizontal transmission among infants and young children. PMID:12075363

  5. An environmentally-friendly, highly efficient, gas pressure-assisted sample introduction system for ICP-MS and its application to detection of cadmium and lead in human plasma.

    PubMed

    Cao, Yupin; Deng, Biyang; Yan, Lizhen; Huang, Hongli

    2017-05-15

    An environmentally friendly and highly efficient gas pressure-assisted sample introduction system (GPASIS) was developed for inductively-coupled plasma mass spectrometry. A GPASIS consisting of a gas-pressure control device, a customized nebulizer, and a custom-made spray chamber was fabricated. The advantages of this GPASIS derive from its high nebulization efficiencies, small sample volume requirements, low memory effects, good precision, and zero waste emission. A GPASIS can continuously, and stably, nebulize 10% NaCl solution for more than an hour without clogging. Sensitivity, detection limits, precision, long-term stability, double charge and oxide ion levels, nebulization efficiencies, and matrix effects of the sample introduction system were evaluated. Experimental results indicated that the performance of this GPASIS, was equivalent to, or better than, those obtained by conventional sample introduction systems. This GPASIS was successfully used to determine Cd and Pb by ICP-MS in human plasma. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. A and B antigen levels acquired by group O donor-derived erythrocytes following ABO-non-identical transfusion or minor ABO-incompatible haematopoietic stem cell transplantation.

    PubMed

    Hult, A K; Dykes, J H; Storry, J R; Olsson, M L

    2017-06-01

    ABO-incompatible haematopoietic stem cell transplantation (HSCT) presents a challenge to blood component transfusion. The aim of this study was to investigate the weak blood group A or B antigen expression by donor-derived group O red blood cells (RBC) observed following transfusion or minor ABO-incompatible HSCT. In addition, in vitro experiments were performed to elucidate possible mechanisms underlying this phenomenon. A sensitive flow cytometry assay for the semi-quantification of RBC A/B antigen levels was used to assess patient samples and evaluate in vitro experiments. Analysis of blood samples from patients, originally typed as A, B and AB but recently transplanted or transfused with cells from group O donors, revealed the A antigen expression on donor-derived RBC, ranging from very low levels in non-secretor individuals to almost subgroup A x -like profiles in group A secretors. The B antigen expression was less readily detectable. In vitro experiments, in which group O donor RBC were incubated with (i) group A/B secretor/non-secretor donor plasma or (ii) group A/B donor RBC in the absence of plasma, supported the proposed adsorption of A/B antigen-bearing glycolipids from secretor plasma but also indicated a secretor-independent mechanism for A/B antigen acquisition as well as direct cell-to-cell transfer of ABO antigens. The in vivo conversion of donor-derived blood group O RBC to ABO subgroup-like RBC after transfusion or minor ABO-incompatible HSCT raises the question of appropriate component selection. Based on these data, AB plasma should be transfused following ABO-incompatible HSCT. © 2017 British Blood Transfusion Society.

  7. Errors in calculated oncotic pressure of dog plasma.

    PubMed

    Gabel, J C; Scott, R L; Adair, T H; Drake, R E; Traber, D L

    1980-12-01

    Several equations to calculate plasma oncotic pressure (pi) from the total protein concentration (C) have been previously described. These equations were derived empirically from samples with a wide range of C obtained by diluting or concentrating normal plasma samples. To test these equations over a range of naturally occurring C, we measured C and pi of plasma samples from 40 dogs. C ranged from 5.3 to 8.7 g/dl and averaged 6.5 +/- 0.1 (mean +/- SE) and pi averaged 17.9 +/- 0.3 mmHg. The regression equation was pi = 78.14 + 1.67 C (r = 0.74). pi increased with C much less than predicted with the commonly used equations. The albumin-to-globulin concentration ratios (A/G), determined in 27 of the dogs, decreased with increasing C (A/G = 1.56-0.128 C, r = 0.62). The lower A/G at the higher C's could cause the lower than predicted increase in pi with C, because the equations were developed from data in which A/G was constant.

  8. Profile of plasma and urine metabolites after the intake of almond [Prunus dulcis (Mill.) D.A. Webb] polyphenols in humans.

    PubMed

    Urpi-Sarda, Mireia; Garrido, Ignacio; Monagas, María; Gómez-Cordovés, Carmen; Medina-Remón, Alexander; Andres-Lacueva, Cristina; Bartolomé, Begoña

    2009-11-11

    Nut skins are considered to be a rich source of polyphenols and may be partially responsible for the numerous health effects associated with nut consumption. However, more bioavailability studies of nut skin polyphenols are needed to understand the health effects derived from nut consumption. The aim of the present study was to determine the profiles of both phase II and microbial-derived phenolic metabolites in plasma and urine samples before and after the intake of almond skin polyphenols by healthy human subjects (n = 2). Glucuronide, O-methyl glucuronide, sulfate, and O-methyl sulfate derivatives of (epi)catechin, as well as the glucuronide conjugates of naringenin and glucuronide and sulfate conjugates of isorhamnetin, were detected in plasma and urine samples after consumption of almond skin polyphenols. The main microbial-derived metabolites of flavanols, such as 5-(dihydroxyphenyl)-gamma-valerolactone and 5-(hydroxymethoxyphenyl)-gamma-valerolactone, were also detected in their glucuronide and sulfate forms. In addition, numerous metabolites derived from further microbial degradation of hydroxyphenylvalerolactones, including hydroxyphenylpropionic, hydroxyphenylacetic, hydroxycinnamic, hydroxybenzoic, and hydroxyhippuric acids, registered major changes in urine after the consumption of almond skin polyphenols. The urinary excretion of these microbial metabolites was estimated to account for a larger proportion of the total polyphenol ingested than phase II metabolites of (epi)catechin, indicating the important role of intestinal bacteria in the metabolism of highly polymerized almond skin polyphenols. To the authors' knowledge this study constitutes the most complete report of the absorption of almond skin polyphenols in humans.

  9. Conversion of α-linolenic acid to long-chain omega-3 fatty acid derivatives and alterations of HDL density subfractions and plasma lipids with dietary polyunsaturated fatty acids in Monk parrots (Myiopsitta monachus).

    PubMed

    Petzinger, C; Larner, C; Heatley, J J; Bailey, C A; MacFarlane, R D; Bauer, J E

    2014-04-01

    The effect of α-linolenic acid from a flaxseed (FLX)-enriched diet on plasma lipid and fatty acid metabolism and possible atherosclerosis risk factors was studied in Monk parrots (Myiopsitta monachus). Twenty-four Monk parrots were randomly assigned to diets containing either 10% ground SUNs or 10% ground FLXs. Feed intake was calculated daily. Blood samples, body condition scores and body weights were obtained at -5 weeks, day 0, 7, 14, 28, 42 and 70. Plasma samples were analysed for total cholesterol, free cholesterol, triacylglycerols and lipoproteins. Phospholipid subfraction fatty acid profiles were determined. By day 70, the FLX group had significantly higher plasma phospholipid fatty acids including 18:3n-3 (α-linolenic acid), 20:5n-3 (eicosapentaenoic acid) and 22:6n-3 (docosahexaenoic acid). The sunflower group had significantly higher plasma phospholipid levels of 20:4n-6 (arachidonic acid). By day 70, the high-density lipoprotein (HDL) peak shifted resulting in significantly different HDL peak densities between the two experimental groups (1.097 g/ml FLX group and 1.095 g/ml SUN group, p = 0.028). The plasma fatty acid results indicate that Monk parrots can readily convert α-linolenic acid to the long-chain omega-3 derivatives including docosahexaenoic acid and reduce 20:4n-6 accumulation in plasma phospholipids. The reason for a shift in the HDL peak density is unknown at this time. Journal of Animal Physiology and Animal Nutrition © 2013 Blackwell Verlag GmbH.

  10. Comparison of the bioavailability of quercetin and catechin in rats.

    PubMed

    Manach, C; Texier, O; Morand, C; Crespy, V; Régérat, F; Demigné, C; Rémésy, C

    1999-12-01

    Quercetin and catechin are present in noticeable amounts in human diet and these polyphenolic compounds are supposed to exert beneficial effects on human health. However, their metabolic fates in the organism have never been compared. In the present study, rats were fed a 0.25% quercetin or a 0.25% catechin diet. Quercetin and catechin metabolites were analyzed in plasma and liver samples by high-performance liquid chromatography coupled to an ultraviolet or a multielectrode coulometric detection. All plasma metabolites were present as conjugated forms, but catechin metabolites were mainly constituted by glucuronidated derivatives, whereas quercetin metabolites were sulfo- and glucurono-sulfo conjugates. Quercetin was more intensively methylated than catechin in plasma. The plasma quercetin metabolites are well maintained during the postabsorptive period (approximately 50 microM), whereas the concentration of catechin metabolites dropped dramatically between 12- and 24-h after an experimental meal (from 38.0 to 4.5 microM). In the liver, the concentrations of quercetin and catechin derivatives were lower than in plasma, and no accumulation was observed when the rats were adapted for 14 d to the supplemented diets. The hepatic metabolites were intensively methylated (90-95%), but in contrast to plasma, some free aglycones could be detected. Thus, it clearly appears that studies dealing with the biological impact of these polyphenols should take into account the feature of their bioavailability, particularly the fact that their circulating metabolites are conjugated derivatives.

  11. The Influence of Tumor-Host Interactions in the Stromal Cell-Derived Factor-1/CXCR4 Ligand/Receptor Axis in Determining Metastatic Risk in Breast Cancer

    PubMed Central

    Hassan, Saima; Ferrario, Cristiano; Saragovi, Uri; Quenneville, Louise; Gaboury, Louis; Baccarelli, Andrea; Salvucci, Ombretta; Basik, Mark

    2009-01-01

    The chemokine stromal cell-derived factor-1 (SDF-1) may function to attract CXCR4-expressing cancer cells to metastatic organs. We have previously demonstrated that low plasma SDF-1, a host-derived marker, increases distant metastatic risk in breast cancer. We therefore hypothesized that tumors overexpressing the SDF-1 receptor CXCR4 have an enhanced ability to metastasize in patients with low plasma SDF-1 levels. In this study, we determined the prognostic significance of activated CXCR4, or phosphorylated CXCR4 (p-CXCR4), and CXCR7, another receptor for SDF-1. Immunohistochemistry was performed on a tissue microarray built using 237 samples from the same cohort of patients for which we measured plasma SDF-1 levels. We found that the prognostic value of p-CXCR4 expression (hazard ratio or HR, 3.95; P = 0.004) was superior to total CXCR4 expression (HR, 3.20; P = 0.03). The rate of breast cancer-specific mortality was much higher in patients with both high p-CXCR4 expression and low plasma SDF-1 levels (HR, 5.96; P < 0.001) than either low plasma SDF-1 (HR, 3.59; P = 0.01) or high p-CXCR4 expression (HR, 3.83; P = 0.005) alone. The added prognostic value of low plasma SDF-1 was only effective in patients with high p-CXCR4 expression, and as such, provides clinical validation for modulation of the metastatic potential of tumor cells by an inherent host-derived metastatic risk factor. PMID:19497995

  12. Higher plasma quercetin levels following oral administration of an onion skin extract compared with pure quercetin dihydrate in humans.

    PubMed

    Burak, Constanze; Brüll, Verena; Langguth, Peter; Zimmermann, Benno F; Stoffel-Wagner, Birgit; Sausen, Udo; Stehle, Peter; Wolffram, Siegfried; Egert, Sarah

    2017-02-01

    To investigate the plasma kinetics of quercetin derived from hard capsules filled with onion skin extract powder or quercetin dihydrate in humans. In a randomized, single-blind, diet-controlled crossover study, 12 healthy subjects (six men and six women) aged 21-33 years were administered a single oral supra-nutritional dose of approximately 163 mg quercetin derived from onion skin extract powder (containing 95.3 % of total flavonoids as quercetin aglycone) or quercetin dihydrate (134 mg quercetin aglycone equivalent). Blood samples were collected before and during a 24-h period after quercetin administration. The concentrations of quercetin and its two monomethylated derivatives, isorhamnetin (3'-O-methyl quercetin), and tamarixetin (4'-O-methyl quercetin), were measured using HPLC with fluorescence detection after plasma enzymatic treatment. The systemic availability, determined by comparing the plasma concentration-time curves of quercetin, was 4.8 times higher, and the maximum plasma concentration (C max ) was 5.4 times higher after ingestion of the onion skin extract than after ingestion of pure quercetin dihydrate. By contrast, t max did not differ significantly between the two formulations. The C max values for isorhamnetin and tamarixetin were 3.8 and 4.4 times higher, respectively, after administration of onion skin extract than after pure quercetin dihydrate. The plasma kinetics of quercetin were not significantly different in men and women. Quercetin aglycone derived from onion skin extract powder is significantly more bioavailable than that from quercetin dihydrate powder filled hard capsules.

  13. Role of red cells and plasma composition on blood sessile droplet evaporation

    NASA Astrophysics Data System (ADS)

    Lanotte, Luca; Laux, Didier; Charlot, Benoît; Abkarian, Manouk

    2017-11-01

    The morphology of dried blood droplets derives from the deposition of red cells, the main components of their solute phase. Up to now, evaporation-induced convective flows were supposed to be at the base of red cell distribution in blood samples. Here, we present a direct visualization by videomicroscopy of the internal dynamics in desiccating blood droplets, focusing on the role of cell concentration and plasma composition. We show that in diluted suspensions, the convection is promoted by the rich molecular composition of plasma, whereas it is replaced by an outward red blood cell displacement front at higher hematocrits. We also evaluate by ultrasounds the effect of red cell deposition on the temporal evolution of sample rigidity and adhesiveness.

  14. Single-centre study of the diagnostic performance of plasma metanephrines with seated sampling for the diagnosis of phaeochromocytoma/paraganglioma.

    PubMed

    Boot, Christopher; Toole, Barry; Johnson, Sarah J; Ball, Stephen; Neely, Dermot

    2017-01-01

    Background Measurement of plasma metanephrines is regarded as one of the best screening tests for phaeochromocytoma/paraganglioma. Current guidelines recommend that samples are ideally collected in the supine position after 30 min rest and interpreted using supine reference ranges, in order to optimize the diagnostic performance of the test. Current practice in our centre is to collect samples for plasma metanephrines from seated patients. The aim of the study was to determine, if seated sampling for plasma metanephrines provides acceptable diagnostic performance in our centre. Methods Clinical and laboratory data of 113 patients, gathered over a four-year period 2010-2014, were reviewed. All had undergone preoperative plasma metanephrines measurement and had postoperative histopathology confirmation or exclusion of phaeochromocytoma/paraganglioma. Results Of 113 patients included in the study, 40 had a histological diagnosis of phaeochromocytoma/paraganglioma. The remaining 73 patients had an alternative adrenal pathology. The diagnostic sensitivity of normetanephrine or metanephrine above the upper limit of our in-house seated reference range was 93%. However, excluding three cases of paraganglioma determined clinically and biochemically to be non-functional raised the sensitivity to 100%. Diagnostic specificity was 90%. Applying published supine reference ranges made no difference to diagnostic sensitivity in this group of patients but decreased diagnostic specificity to 75%. Conclusions While these data are derived from a relatively small study population, they demonstrate acceptable diagnostic performance for seated plasma metanephrines as a screening test for phaeochromocytoma/paraganglioma. These data highlight a high diagnostic sensitivity for plasma metanephrines with seated sampling in our centre.

  15. Concentration of platelets and growth factors in platelet-rich plasma from Goettingen minipigs.

    PubMed

    Jungbluth, Pascal; Grassmann, Jan-Peter; Thelen, Simon; Wild, Michael; Sager, Martin; Windolf, Joachim; Hakimi, Mohssen

    2014-01-01

    In minipigs little is known about the concentration of growth factors in plasma, despite their major role in several patho-physiological processes such as healing of fractures. This prompted us to study the concentration of platelets and selected growth factors in plasma and platelet-rich plasma (PRP) preparation of sixteen Goettingen minipigs. Platelet concentrations increased significantly in PRP in comparison to native blood plasma. Generally, significant increase in the concentration of all growth factors tested was observed in the PRP in comparison to the corresponding plasma or serum. Five of the plasma samples examined contained detectable levels of bone morphogenic protein 2 (BMP-2) whereas eleven of the plasma or serum samples contained minimal amounts of vascular endothelial growth factor (VEGF) and platelet-derived growth factor (PDGF-bb) respectively. On the other hand variable concentrations of bone morphogenic protein 7 (BMP-7) and transforming growth factor β1 (TGF-β1) were measured in all plasma samples. In contrast, all PRP samples contained significantly increased amounts of growth factors. The level of BMP-2, BMP-7, TGF-β1, VEGF and PDGF-bb increased by 17.6, 1.5, 7.1, 7.2 and 103.3 fold, in comparison to the corresponding non-enriched preparations. Moreover significant positive correlations were found between platelet count and the concentrations of BMP-2 (r=0.62, p<0.001), TGF-β1 (r=0.85, p<0.001), VEGF (r=0.46, p<0.01) and PDGF-bb (r=0.9, p<0.001). Our results demonstrate that selected growth factors are present in the platelet-rich plasma of minipigs which might thus serve as a source of autologous growth factors.

  16. [Brain-derived neurotrophic factor (BDNF) and nerve growth factor (NGF) blood levels in patients with acute carbon monoxide poisoning - a preliminary observations].

    PubMed

    Ciszowski, Krzysztof; Gomółka, Ewa; Gawlikowski, Tomasz; Szpak, Dorota; Potoczek, Anna; Boba, Magdalena

    Neurotrophins are the family of proteins which stimulate and regulate the process of neurogenesis. Several factors belong to the family, mainly nerve growth factor (NGF), brain-derived neurotrophic factor (BDNF), neurotrophin-3 (NT 3), and neurotrophin-4/5 (NT-4/5). Acute poisoning with carbon monoxide (CO), which usually is accompanied by neurologic symptoms, can potentially change the secretion profile of neurotrophins. Aim of the study. The main goal of the study is to assess the changes of NGF and BDNF plasma levels during an acute phase of CO poisoning as well as immediately after recovery. Additionally, the relationship among neurotrophin levels and selected aspects of clinical course of CO poisoning were studied. The study group consisted of 18 patients (mean age: 31.8±10.3 years) hospitalized in Toxicology Department of University Hospital in Cracow because of acute CO poisoning. There were 10 women (mean age: 30.2±6.9 years) and 8 men (mean age 33.9±13.7 years) in the group. The levels of NGF and BDNF were evaluated using immunoenzymatic method (ELISA) in plasma samples taken thrice in each patient. The sample 1. was taken during hospital admission, the sample 2. about 12-36 hours after admission, and the sample 3. just before the hospital discharging (usually, on the 3rd-4th day). The clinical data were collected from patients’ anamnesis, physical examination and neuropsychological evaluation. The statistical analysis were performed using tools comprised in STATISTICA 12.0 PL (StatSoft Polska, Cracow, Poland) software. The majority of NGF plasma levels were less than 14 pg/mL (values below the limit of quantification), contrary to the sole case of 34.3 pg/mL. BDNF plasma levels ranged from 4.8 ng/mL to above 48 ng/mL, i.e. they were higher than the upper limit of measurement range for the plasma dilution which had been used. The comparison of NGF and BDNF plasma levels in the study group with their analogues in healthy volunteers taken from the literature indicates that NGF level declines and BDNF level rises in patients with CO poisoning. The profile of BDNF concentrations in the majority of patients formed the characteristic pattern: BDNF sample 1. > BDNF sample 2. < BDNF sample 3. Taking all the values of BDNF higher than 48 ng/mL as equal to 48 ng/ mL, the statistically significant difference among 3 sample series was found according to BDNF levels. Maintaining the above mentioned assumption, the statistically significant negative correlation between the number of higher cognitive functions disturbed in one patient at the same time and the BDNF levels in sample series 2 was discovered, as well as the weak correlations between BDNF level in sample series 1 and carboxyhaemoglobin or lactate level. Moreover, weak but statistically significant correlations were present between the duration of CO exposure and BDNF levels in each sample series. The NGF plasma level is probably declined, while the BDNF plasma level is increased in patients with acute CO poisoning. The concentration–time curve for the plasma BDNF may sometimes undergo fluctuations with two peaks on its course. Plasma BDNF level may serve as a biological marker of disturbed higher cognitive functions in acute CO poisoning. Some clinical aspects of CO poisoning (duration of exposure, HbCO and lactate blood levels) may influence BDNF level.

  17. Different exosome cargo from plasma/bronchoalveolar lavage in non-small-cell lung cancer.

    PubMed

    Rodríguez, Marta; Silva, Javier; López-Alfonso, Ana; López-Muñiz, María Belen; Peña, Cristina; Domínguez, Gemma; García, Jose Miguel; López-Gónzalez, Ana; Méndez, Miriam; Provencio, Mariano; García, Vanesa; Bonilla, Félix

    2014-09-01

    Tumor-derived exosomes mediate tumorigenesis by facilitating tumor growth, metastasis, development of drug resistance, and immunosuppression. However, little is known about the exosomes isolated from bronchoalveolar lavage (BAL) in patients with lung neoplasm. Exosomes isolated in plasma and BAL from 30 and 75 patients with tumor and nontumor pathology were quantified by acetylcholinesterase activity and characterized by Western Blot, Electron Microscopy, and Nanoparticle Tracking Analysis. Differences in exosome cargo were analyzed by miRNA quantitative PCR in pooled samples and validated in a second series of patients. More exosomes were detected in plasma than in BAL in both groups (P < 0.001). The most miRNAs evaluated by PCR array were detected in tumor plasma, tumor BAL, and nontumor BAL pools, but only 56% were detected in the nontumor plasma pool. Comparing the top miRNAs with the highest levels detected in each pool, we found close homology only between the BAL samples of the two pathologies. In tumor plasma, we found a higher percentage of miRNAs with increased levels than in tumor BAL or in nontumor plasma. The data reveal differences between BAL and plasma exosome amount and miRNA content. © 2014 Wiley Periodicals, Inc.

  18. Experimentally testing the dependence of momentum transport on second derivatives using Gaussian process regression

    NASA Astrophysics Data System (ADS)

    Chilenski, M. A.; Greenwald, M. J.; Hubbard, A. E.; Hughes, J. W.; Lee, J. P.; Marzouk, Y. M.; Rice, J. E.; White, A. E.

    2017-12-01

    It remains an open question to explain the dramatic change in intrinsic rotation induced by slight changes in electron density (White et al 2013 Phys. Plasmas 20 056106). One proposed explanation is that momentum transport is sensitive to the second derivatives of the temperature and density profiles (Lee et al 2015 Plasma Phys. Control. Fusion 57 125006), but it is widely considered to be impossible to measure these higher derivatives. In this paper, we show that it is possible to estimate second derivatives of electron density and temperature using a nonparametric regression technique known as Gaussian process regression. This technique avoids over-constraining the fit by not assuming an explicit functional form for the fitted curve. The uncertainties, obtained rigorously using Markov chain Monte Carlo sampling, are small enough that it is reasonable to explore hypotheses which depend on second derivatives. It is found that the differences in the second derivatives of n{e} and T{e} between the peaked and hollow rotation cases are rather small, suggesting that changes in the second derivatives are not likely to explain the experimental results.

  19. Increased circulating leukocyte-derived microparticles in ischemic cerebrovascular disease.

    PubMed

    He, Zhangping; Tang, Yanyan; Qin, Chao

    2017-06-01

    Circulating leukocyte-derived microparticles act as proinflammatory mediators that reflect vascular inflammation. In this study, we examined the hypothesis that the quantity of leukocyte-derived microparticles is increased in patients with ischemic cerebrovascular diseases, and investigated utility of various phenotypes of leukocyte-derived microparticles as specific biomarkers of vascular inflammation injury. Additionally we focused on identifying leukocyte-derived microparticles that may be correlated with stroke severity in acute ischemic stroke patients. The plasma concentration of leukocyte-derived microparticles obtained by a series of centrifugations of 76 consecutive patients with ischemic cerebrovascular diseases and 70 age-, sex-, and race-matched healthy controls were determined by flow cytometry. Significantly elevated numbers of leukocyte (CD45+), monocyte (CD14+), lymphocyte (CD4+), granulocyte (CD15+) derived microparticles were found in the plasma samples of patients ischemic cerebrovascular diseases, compared to healthy controls (p<0.05). Furthermore, the plasma levels of CD14+ microparticles were significantly correlated with stroke severity (r=0.355, p=0.019), cerebral vascular stenosis severity (r=0.255, p=0.025) and stroke subtype (r=0.242, p=0.036). No association with stroke was observed for other leukocyte-derived phenotypes. These results demonstrate that circulating leukocyte-derived microparticles amounts are increased in patients with ischemic cerebrovascular diseases, compared with healthy controls. As proinflammatory mediators, leukocyte-derived microparticles may contribute to vascular inflammatory and the inflammatory process in acute ischemic stroke. Levels of CD14+ microparticles may be a promising biomarker of ischemic severity and outcome of stroke in the clinic. Copyright © 2017 Elsevier Ltd. All rights reserved.

  20. TnBP⁄Triton X-45 Treatment of Plasma for Transfusion Efficiently Inactivates Hepatitis C Virus

    PubMed Central

    Chou, Ming-Li; Burnouf, Thierry; Chang, Shun-Pang; Hung, Ting-Chun; Lin, Chun-Ching; Richardson, Christopher D.; Lin, Liang-Tzung

    2015-01-01

    Risk of transmission of hepatitis C virus (HCV) by clinical plasma remains high in countries with a high prevalence of hepatitis C, justifying the implementation of viral inactivation treatments. In this study, we assessed the extent of inactivation of HCV during minipool solvent/detergent (SD; 1% TnBP / 1% Triton X-45) treatment of human plasma. Luciferase-tagged infectious cell culture-derived HCV (HCVcc) particles were used to spike human plasma prior to treatment by SD at 31 ± 0.5°C for 30 min. Samples were taken before and after SD treatment and filtered on a Sep-Pak Plus C18 cartridge to remove the SD agents. Risk of cytotoxicity was assessed by XTT cell viability assay. Viral infectivity was analyzed based on the luciferase signals, 50% tissue culture infectious dose viral titer, and immunofluorescence staining for HCV NS5A protein. Total protein, cholesterol, and triglyceride contents were determined before and after SD treatment and C18 cartridge filtration. Binding analysis, using patient-derived HCV clinical isolates, was also examined to validate the efficacy of the inactivation by SD. SD treatment effectively inactivated HCVcc within 30 min, as demonstrated by the baseline level of reporter signals, total loss of viral infectivity, and absence of viral protein NS5A. SD specifically targeted HCV particles to render them inactive, with essentially no effect on plasma protein content and hemostatic function. More importantly, the efficacy of the SD inactivation method was confirmed against various genotypes of patient-derived HCV clinical isolates and against HCVcc infection of primary human hepatocytes. Therefore, treatment by 1% TnBP / 1% Triton X-45 at 31°C is highly efficient to inactivate HCV in plasma for transfusion, showing its capacity to enhance the safety of therapeutic plasma products. We propose that the methodology used here to study HCV infectivity can be valuable in the validation of viral inactivation and removal processes of human plasma-derived products. PMID:25658612

  1. Plasma exosomal α-synuclein is likely CNS-derived and increased in Parkinson’s disease

    PubMed Central

    Cook, Travis J.; Bullock, Kristin M.; Zhao, Yanchun; Ginghina, Carmen; Li, Yanfei; Aro, Patrick; Dator, Romel; He, Chunmei; Hipp, Michael J.; Zabetian, Cyrus P.; Peskind, Elaine R.; Hu, Shu-Ching; Quinn, Joseph F.; Galasko, Douglas R.; Banks, William A.; Zhang, Jing

    2014-01-01

    Extracellular α-synuclein is important in the pathogenesis of Parkinson disease (PD) and also as a potential biomarker when tested in the cerebrospinal fluid (CSF). The performance of blood plasma or serum α-synuclein as a biomarker has been found to be inconsistent and generally ineffective, largely due to the contribution of peripherally derived α-synuclein. In this study, we discovered, via an intracerebroventricular injection of radiolabeled α-synuclein into mouse brain, that CSF α-synuclein was readily transported to blood, with a small portion being contained in exosomes that are relatively specific to the central nervous system (CNS). Consequently, we developed a technique to evaluate the levels of α-synuclein in these exosomes in individual plasma samples. When applied to a large cohort of clinical samples (267 PD, 215 controls), we found that in contrast to CSF α-synuclein concentrations, which are consistently reported to be lower in PD patients compared to controls, the levels of plasma exosomal α-synuclein were substantially higher in PD patients, suggesting an increased efflux of the protein to the peripheral blood of these patients. Furthermore, although no association was observed between plasma exosomal and CSF α-synuclein, a significant correlation between plasma exosomal α-synuclein and disease severity (r=0.176, p=0.004) was observed, and the diagnostic sensitivity and specificity achieved by plasma exosomal α-synuclein were comparable to those determined by CSF α-synuclein. Further studies are clearly needed to elucidate the mechanism involved in the transport of CNS α-synuclein to the periphery, which may lead to a more convenient and robust assessment of PD clinically. PMID:24997849

  2. Simple, miniaturized blood plasma extraction method.

    PubMed

    Kim, Jin-Hee; Woenker, Timothy; Adamec, Jiri; Regnier, Fred E

    2013-12-03

    A rapid plasma extraction technology that collects a 2.5 μL aliquot of plasma within three minutes from a finger-stick derived drop of blood was evaluated. The utility of the plasma extraction cards used was that a paper collection disc bearing plasma was produced that could be air-dried in fifteen minutes and placed in a mailing envelop for transport to an analytical laboratory. This circumvents the need for venipuncture and blood collection in specialized vials by a phlebotomist along with centrifugation and refrigerated storage. Plasma extraction was achieved by applying a blood drop to a membrane stack through which plasma was drawn by capillary action. During the course of plasma migration to a collection disc at the bottom of the membrane stack blood cells were removed by a combination of adsorption and filtration. After the collection disc filled with an aliquot of plasma the upper membranes were stripped from the collection card and the collection disc was air-dried. Intercard differences in the volume of plasma collected varied approximately 1% while volume variations of less than 2% were seen with hematocrit levels ranging from 20% to 71%. Dried samples bearing metabolites and proteins were then extracted from the disc and analyzed. 25-Hydroxy vitamin D was quantified by LC-MS/MS analysis following derivatization with a secosteroid signal enhancing tag that imparted a permanent positive charge to the vitamin and reduced the limit of quantification (LOQ) to 1 pg of collected vitamin on the disc; comparable to values observed with liquid-liquid extraction (LLE) of a venipuncture sample. A similar study using conventional proteomics methods and spectral counting for quantification was conducted with yeast enolase added to serum as an internal standard. The LOQ with extracted serum samples for enolase was 1 μM, linear from 1 to 40 μM, the highest concentration examined. In all respects protein quantification with extracted serum samples was comparable to that observed with serum samples obtained by venipuncture.

  3. Absolute Quantification of Middle- to High-Abundant Plasma Proteins via Targeted Proteomics.

    PubMed

    Dittrich, Julia; Ceglarek, Uta

    2017-01-01

    The increasing number of peptide and protein biomarker candidates requires expeditious and reliable quantification strategies. The utilization of liquid chromatography coupled to quadrupole tandem mass spectrometry (LC-MS/MS) for the absolute quantitation of plasma proteins and peptides facilitates the multiplexed verification of tens to hundreds of biomarkers from smallest sample quantities. Targeted proteomics assays derived from bottom-up proteomics principles rely on the identification and analysis of proteotypic peptides formed in an enzymatic digestion of the target protein. This protocol proposes a procedure for the establishment of a targeted absolute quantitation method for middle- to high-abundant plasma proteins waiving depletion or enrichment steps. Essential topics as proteotypic peptide identification and LC-MS/MS method development as well as sample preparation and calibration strategies are described in detail.

  4. Elemental analysis of urinary calculi by laser induced plasma spectroscopy.

    PubMed

    Fang, Xiao; Ahmad, S Rafi; Mayo, Mike; Iqbal, Syed

    2005-12-01

    Laser induced plasma spectroscopy (LIPS) has been applied to analyse and identify elemental constituents of urinary calculi. Measurements on seven different urinary stone samples were conducted and the concentrations of some key elemental species were estimated. The elements detected with the present system were: Calcium, Magnesium, Sodium, Samarium, Potassium and Lead. Absolute concentrations of the species were derived from pre-calibration of the system for each element. Their concentrations were found to be widely different in different samples. It was observed that the samples containing a significant amount of lead have large proportion of calcium. It has been established that LIPS would allow real time clinic measurements of elemental contents and the concentrations in the biomaterials without sample preparation. The technique has the potential for routine clinic applications in urological disorder diagnosis.

  5. Measurement of plasma unbound unconjugated bilirubin.

    PubMed

    Ahlfors, C E

    2000-03-15

    A method is described for measuring the unconjugated fraction of the unbound bilirubin concentration in plasma by combining the peroxidase method for determining unbound bilirubin with a diazo method for measuring conjugated and unconjugated bilirubin. The accuracy of the unbound bilirubin determination is improved by decreasing sample dilution, eliminating interference by conjugated bilirubin, monitoring changes in bilirubin concentration using diazo derivatives, and correcting for rate-limiting dissociation of bilirubin from albumin. The unbound unconjugated bilirubin concentration by the combined method in plasma from 20 jaundiced newborns was significantly greater than and poorly correlated with the unbound bilirubin determined by the existing peroxidase method (r = 0.7), possibly due to differences in sample dilution between the methods. The unbound unconjugated bilirubin was an unpredictable fraction of the unbound bilirubin in plasma samples from patients with similar total bilirubin concentrations but varying levels of conjugated bilirubin. A bilirubin-binding competitor was readily detected at a sample dilution typically used for the combined test but not at the dilution used for the existing peroxidase method. The combined method is ideally suited to measuring unbound unconjugated bilirubin in jaundiced human newborns or animal models of kernicterus. Copyright 2000 Academic Press.

  6. Quantification of 18F-fluorocholine kinetics in patients with prostate cancer.

    PubMed

    Verwer, Eline E; Oprea-Lager, Daniela E; van den Eertwegh, Alfons J M; van Moorselaar, Reindert J A; Windhorst, Albert D; Schwarte, Lothar A; Hendrikse, N Harry; Schuit, Robert C; Hoekstra, Otto S; Lammertsma, Adriaan A; Boellaard, Ronald

    2015-03-01

    Choline kinase is upregulated in prostate cancer, resulting in increased (18)F-fluoromethylcholine uptake. This study used pharmacokinetic modeling to validate the use of simplified methods for quantification of (18)F-fluoromethylcholine uptake in a routine clinical setting. Forty-minute dynamic PET/CT scans were acquired after injection of 204 ± 9 MBq of (18)F-fluoromethylcholine, from 8 patients with histologically proven metastasized prostate cancer. Plasma input functions were obtained using continuous arterial blood-sampling as well as using image-derived methods. Manual arterial blood samples were used for calibration and correction for plasma-to-blood ratio and metabolites. Time-activity curves were derived from volumes of interest in all visually detectable lymph node metastases. (18)F-fluoromethylcholine kinetics were studied by nonlinear regression fitting of several single- and 2-tissue plasma input models to the time-activity curves. Model selection was based on the Akaike information criterion and measures of robustness. In addition, the performance of several simplified methods, such as standardized uptake value (SUV), was assessed. Best fits were obtained using an irreversible compartment model with blood volume parameter. Parent fractions were 0.12 ± 0.4 after 20 min, necessitating individual metabolite corrections. Correspondence between venous and arterial parent fractions was low as determined by the intraclass correlation coefficient (0.61). Results for image-derived input functions that were obtained from volumes of interest in blood-pool structures distant from tissues of high (18)F-fluoromethylcholine uptake yielded good correlation to those for the blood-sampling input functions (R(2) = 0.83). SUV showed poor correlation to parameters derived from full quantitative kinetic analysis (R(2) < 0.34). In contrast, lesion activity concentration normalized to the integral of the blood activity concentration over time (SUVAUC) showed good correlation (R(2) = 0.92 for metabolite-corrected plasma; 0.65 for whole-blood activity concentrations). SUV cannot be used to quantify (18)F-fluoromethylcholine uptake. A clinical compromise could be SUVAUC derived from 2 consecutive static PET scans, one centered on a large blood-pool structure during 0-30 min after injection to obtain the blood activity concentrations and the other a whole-body scan at 30 min after injection to obtain lymph node activity concentrations. © 2015 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  7. Screening for and validated quantification of amphetamines and of amphetamine- and piperazine-derived designer drugs in human blood plasma by gas chromatography/mass spectrometry.

    PubMed

    Peters, Frank T; Schaefer, Simone; Staack, Roland F; Kraemer, Thomas; Maurer, Hans H

    2003-06-01

    The classical stimulants amphetamine, methamphetamine, ethylamphetamine and the amphetamine-derived designer drugs MDA, MDMA ('ecstasy'), MDEA, BDB and MBDB have been widely abused for a relatively long time. In recent years, a number of newer designer drugs have entered the illicit drug market. 4-Methylthioamphetamine (MTA), p-methoxyamphetamine (PMA) and p-methoxymethamphetamine (PMMA) are also derived from amphetamine. Other designer drugs are derived from piperazine, such as benzylpiperazine (BZP), methylenedioxybenzylpiperazine (MDBP), trifluoromethylphenylpiperazine (TFMPP), m-chlorophenylpiperazine (mCPP) and p-methoxyphenylpiperazine (MeOPP). A number of severe or even fatal intoxications involving these newer substances, especially PMA, have been reported. This paper describes a method for screening for and simultaneous quantification of the above-mentioned compounds and the metabolites p-hydroxyamphetamine and p-hydroxymethamphetamine (pholedrine) in human blood plasma. The analytes were analyzed by gas chromatography/mass spectrometry in the selected-ion monitoring mode after mixed-mode solid-phase extraction (HCX) and derivatization with heptafluorobutyric anhydride. The method was fully validated according to international guidelines. It was linear from 5 to 1000 micro g l(-1) for all analytes. Data for accuracy and precision were within required limits with the exception of those for MDBP. The limit of quantification was 5 micro g l(-1) for all analytes. The applicability of the assay was proven by analysis of authentic plasma samples and of a certified reference sample. This procedure should also be suitable for confirmation of immunoassay results positive for amphetamines and/or designer drugs of the ecstasy type. Copyright 2003 John Wiley & Sons, Ltd.

  8. Evaluation of Different Blood Collection Tubes and Blood Storage Conditions for the Preservation and Stability of Cell-Free Circulating DNA for the Analysis of the Methylated mSEPT9 Colorectal Cancer Screening Marker.

    PubMed

    Distler, Jurgen; Tetzner, Reimo; Weiss, Gunter; König, Thomas; Schlegel, Anne; Bagrowski, Michal

    2016-01-01

    For the subsequent analysis of the methylated mSEPT9 colorectal cancer screening marker in plasma, different blood collection tubes and blood storage conditions were investigated. The study demonstrated that methylated Septin 9 ( m SEPT9) can be consistently detected in plasma samples derived from whole blood samples collected with S-Monovette® K3E and BD Vacutainer ® K2EDTA tubes stored at 2-8 °C for a maximum of 24 h and for samples collected in S-Monovette CPDA tubes stored at 18-25 °C for up to 48 h.

  9. Minimal alteration in the ratio of circulatory fetal DNA to fetal corticotropin-releasing hormone mRNA level in preeclampsia.

    PubMed

    Zhong, Xiao Yan; Holzgreve, Wolfgang; Gebhardt, Stefan; Hillermann, Renate; Tofa, Kashefa Carelse; Gupta, Anurag Kumar; Huppertz, Berthold; Hahn, Sinuhe

    2006-01-01

    We have recently observed that fetal DNA and fetal corticotropin-releasing hormone (CRH) mRNA are associated with in vitro generated syncytiotrophoblast-derived microparticles, and that the ratio of fetal DNA to mRNA (CRH) varied according to whether the particles were derived by predominantly apoptotic, apo-necrotic or necrotic pathways. Hence, we examined whether these ratios varied in maternal plasma samples taken from normotensive and preeclamptic pregnancies in vivo. Maternal plasma samples were collected from 18 cases with preeclampsia and 29 normotensive term controls. Circulatory fetal CRH mRNA and DNA levels were quantified by real-time PCR and RT-PCR. Circulatory fetal mRNA and fetal DNA levels were significantly elevated in the preeclampsia study group when compared to normotensive controls. Alterations in the fetal mRNA to DNA ratio between the study and control groups were minimal, even when stratified into early (<34 weeks of gestation) and late (>34 weeks of gestation) onset preeclampsia. Our data suggest that although circulatory fetal DNA and mRNA levels are significantly elevated in preeclampsia, the ratios in maternal plasma are not dramatically altered. Copyright 2006 S. Karger AG, Basel.

  10. Profiling of the compounds absorbed in human plasma and urine after oral administration of a traditional Japanese (kampo) medicine, daikenchuto.

    PubMed

    Iwabu, Jun; Watanabe, Junko; Hirakura, Kazuhiro; Ozaki, Yoshinori; Hanazaki, Kazuhiro

    2010-11-01

    Daikenchuto (DKT), a pharmaceutical-grade traditional Japanese (Kampo) medicine, has been widely used for the treatment of various gastrointestinal disorders including postoperative ileus and has been integrated into the modern medical care system in Japan as a prescription drug. DKT is a multiherbal medicine consisting of Japanese pepper (zanthoxylum fruit), processed ginger, and ginseng with maltose as an additive. Despite substantial research on the pharmacological activities of DKT and its ingredients, the lack of studies on absorption, distribution, metabolism, and excretion of DKT has made it difficult to obtain a consistent picture of its mechanism of action. In the present study, we constructed an analysis procedure consisting of seven conditions of liquid chromatography and mass spectrometric analysis, which enabled the identification of 44 ingredients of DKT component herbs. We investigated the plasma and urine profiles of these ingredients 0.5 to 8 h after oral administration of 15.0 g of DKT in four healthy volunteers. The results indicated that 1) hydroxy-α-sanshool and [6]-shogaol, the prominent peaks in plasma derived from Japanese pepper and ginger, respectively, were detected at 0.5 h and thereafter decreased throughout the sampling period; 2) ginsenoside Rb(1), a prominent peak derived from ginseng, increased gradually during the sampling period; 3) glucuronide conjugates of hydroxy-sanshools, shogaols, and gingerols were detected in plasma and urine; and 4) no obvious differences between samples from the two male and the two female individuals were observed. These results provide a strong basis for future studies on pharmacokinetics and pharmacology of DKT.

  11. The State of the Human Proteome in 2013 as viewed through PeptideAtlas: Comparing the Kidney, Urine, and Plasma Proteomes for the Biology and Disease-driven Human Proteome Project

    PubMed Central

    Farrah, Terry; Deutsch, Eric W.; Omenn, Gilbert S.; Sun, Zhi; Watts, Julian D.; Yamamoto, Tadashi; Shteynberg, David; Harris, Micheleen M.; Moritz, Robert L.

    2014-01-01

    The kidney, urine, and plasma proteomes are intimately related: proteins and metabolic waste products are filtered from the plasma by the kidney and excreted via the urine, while kidney proteins may be secreted into the circulation or released into the urine. Shotgun proteomics datasets derived from human kidney, urine, and plasma samples were collated and processed using a uniform software pipeline, and relative protein abundances were estimated by spectral counting. The resulting PeptideAtlas builds yielded 4005, 2491, and 3553 nonredundant proteins at 1% FDR for the kidney, urine, and plasma proteomes, respectively—for kidney and plasma, the largest high-confidence protein sets to date. The same pipeline applied to all available human data yielded a 2013 Human PeptideAtlas build containing 12,644 nonredundant proteins and at least one peptide for each of ~14,000 Swiss-Prot entries, an increase over 2012 of ~7.5% of the predicted human proteome. We demonstrate that abundances are correlated between plasma and urine, examine the most abundant urine proteins not derived from either plasma or kidney, and consider the biomarker potential of proteins associated with renal decline. This analysis forms part of the Biology and Disease-driven Human Proteome Project (B/D-HPP) and a contribution to the Chromosome-centric Human Proteome Project (C-HPP) special issue. PMID:24261998

  12. Organ tropic metastatic secretomes and exosomes in breast cancer

    DTIC Science & Technology

    2017-10-01

    integrins, functionally relevant in organ- 11 tropic, specifically lung-tropic breast cancer metastasis, and tested these samples by ELISA (protein...guided by the results of our exosomal proteomics analysis, we had previously performed ELISA assays for plasma-derived exosomal integrins in breast

  13. On quasi-thermal fluctuations near the plasma frequency in the outer plasmasphere: A case study

    NASA Technical Reports Server (NTRS)

    Lund, E. J.; Labelle, J.; Treumann, R. A.

    1994-01-01

    We present a derivation of the quasi-thermal electrostatic fluctuation power spectrum in a mult-Maxwellian plasma and show sample calculated spectra. We then apply this theory, which has been successfully applied in oter regions of space, to spectra from two Active Magnetospheric Particle Tracer Explorer/Ion Release Module (AMPTER IRM) passes through the duskside plasmasphere. WE show that the plasma line that is often seen in this region is usually quasi-thermal in origin. We obtain a refined estimate of the plasma frequency and infer a cold electron temperature which is consistent within a factor of 2 with both models and previous meausurements by other techniques, but closer investigation reveals that details of the plasma line cannot be explained with the ususal two isotropic Maxwellian model.

  14. Simultaneous quantification of the organophosphorus pesticides dimethoate and omethoate in porcine plasma and urine by LC-ESI-MS/MS and flow-injection-ESI-MS/MS.

    PubMed

    John, Harald; Eddleston, Michael; Clutton, R Eddie; Worek, Franz; Thiermann, Horst

    2010-05-15

    Dimethoate is an organophosphorus toxicant used in agri- and horticulture as a systemic broad-spectrum insecticide. It also exhibits toxic activity towards mammalian organism provoked by catalytic desulfuration in the liver producing its oxon-derivative omethoate thus inhibiting acetylcholinesterase, initiating cholinergic crisis and ultimately leading to death by respiratory paralysis and cardiovascular collapse. Pharmaco- and toxicokinetic studies in animal models help to broaden basic understanding of medical intervention by antidotes and supportive care. Therefore, we developed and validated a LC-ESI-MS/MS method suitable for the simultaneous, selective, precise (RSD(intra-day) 1-8%; RSD(inter-day) 5-14%), accurate (intra-day: 95-107%; inter-day: 90-115%), and robust quantification of both pesticides from porcine urine and plasma after deproteinization by precipitation and extensive dilution (1:11,250 for plasma and 1:40,000 for urine). Accordingly, lower limits of quantification (0.24-0.49 microg/ml plasma and 0.78-1.56 microg/ml urine) and lower limits of detection (0.12-0.24 microg/ml plasma and 0.39-0.78 microg/ml urine) were equivalent to quite low absolute on-column amounts (1.1-2.1 pg for plasma and 2.0-3.9 pg for urine). The calibration range (0.24-250 microg/ml plasma and 0.78-200 microg/ml urine) was subdivided into two linear ranges (r(2)>or=0.998) each covering nearly two orders of magnitude. The lack of any interfering peak in 6 individual blank specimens from plasma and urine demonstrated the high selectivity of the method. Furthermore, extensive sample dilution causing lowest concentration of potentially interfering matrix ingredients prompted us to develop and validate an additional flow-injection method (FI-ESI-MS/MS). Validation characteristics were as good as for the chromatographic method but sample throughput was enhanced by a factor of 6. Effects on ionization provoked by plasma and urine matrix from 6 individuals as well as in the presence of therapeutics (antidotes) administered in an animal study were investigated systematically underlying in the reliability of the presented methods. Both methods were applied to porcine samples derived from an in vivo animal study. Copyright (c) 2010 Elsevier B.V. All rights reserved.

  15. The role of BDNF, leptin, and catecholamines in reward learning in bulimia nervosa.

    PubMed

    Homan, Philipp; Grob, Simona; Milos, Gabriella; Schnyder, Ulrich; Eckert, Anne; Lang, Undine; Hasler, Gregor

    2014-12-07

    A relationship between bulimia nervosa and reward-related behavior is supported by several lines of evidence. The dopaminergic dysfunctions in the processing of reward-related stimuli have been shown to be modulated by the neurotrophin brain derived neurotrophic factor (BDNF) and the hormone leptin. Using a randomized, double-blind, placebo-controlled, crossover design, a reward learning task was applied to study the behavior of 20 female subjects with remitted bulimia nervosa and 27 female healthy controls under placebo and catecholamine depletion with alpha-methyl-para-tyrosine (AMPT). The plasma levels of BDNF and leptin were measured twice during the placebo and the AMPT condition, immediately before and 1 hour after a standardized breakfast. AMPT-induced differences in plasma BDNF levels were positively correlated with the AMPT-induced differences in reward learning in the whole sample (P=.05). Across conditions, plasma brain derived neurotrophic factor levels were higher in remitted bulimia nervosa subjects compared with controls (diagnosis effect; P=.001). Plasma BDNF and leptin levels were higher in the morning before compared with after a standardized breakfast across groups and conditions (time effect; P<.0001). The plasma leptin levels were higher under catecholamine depletion compared with placebo in the whole sample (treatment effect; P=.0004). This study reports on preliminary findings that suggest a catecholamine-dependent association of plasma BDNF and reward learning in subjects with remitted bulimia nervosa and controls. A role of leptin in reward learning is not supported by this study. However, leptin levels were sensitive to a depletion of catecholamine stores in both remitted bulimia nervosa and controls. © The Author 2015. Published by Oxford University Press on behalf of CINP.

  16. Plasma enhancement of in vitro attachment of rat bone-marrow-derived stem cells on cross-linked gelatin films.

    PubMed

    Prasertsung, I; Kanokpanont, S; Mongkolnavin, R; Wong, C S; Panpranot, J; Damrongsakkul, S

    2012-01-01

    In this work, nitrogen, oxygen and air glow discharges powered by 50 Hz AC power supply are used for the treatment of type-A gelatin film cross-linked by a dehydrothermal (DHT) process. The properties of cross-linked gelatin were characterized by contact angle measurement, atomic force microscopy (AFM) and X-ray photoelectron spectroscopy (XPS) analysis. The results showed that the water contact angle of gelatin films decrease with increasing plasma treatment time. The treatment of nitrogen, oxygen and air plasma up to 30 s had no effects on the surface roughness of the gelatin film as revealed by AFM results. The XPS analysis showed that the N-containing functional groups generated by nitrogen and air plasma, and O-containing functional groups generated by oxygen and air plasmas were incorporated onto the film surface, the functional groups were found to increase with increasing treatment time. An in vitro test using rat bone-marrow-mesenchym-derived stem cells (MSCs) revealed that the number of cells attached on plasma-treated gelatin films was significantly increased compared to untreated samples. The best enhancement of cell attachment was noticed when the film was treated with nitrogen plasma for 15-30 s, oxygen plasma for 3 s, and air plasma for 9 s. In addition, among the three types of plasmas used, nitrogen plasma treatment gave the best MSCs attachment on the gelatin surface. The results suggest that a type-A gelatin film with water contact angle of 27-28° and an O/N ratio of 1.4 is most suitable for MSCs attachment.

  17. A Gestational Profile of Placental Exosomes in Maternal Plasma and Their Effects on Endothelial Cell Migration

    PubMed Central

    Salomon, Carlos; Torres, Maria Jose; Kobayashi, Miharu; Scholz-Romero, Katherin; Sobrevia, Luis; Dobierzewska, Aneta; Illanes, Sebastian E.; Mitchell, Murray D.; Rice, Gregory E.

    2014-01-01

    Studies completed to date provide persuasive evidence that placental cell-derived exosomes play a significant role in intercellular communication pathways that potentially contribute to placentation and development of materno-fetal vascular circulation. The aim of this study was to establish the gestational-age release profile and bioactivity of placental cell-derived exosome in maternal plasma. Plasma samples (n = 20 per pregnant group) were obtained from non-pregnant and pregnant women in the first (FT, 6–12 weeks), second (ST, 22–24 weeks) and third (TT, 32–38 weeks) trimester. The number of exosomes and placental exosome contribution were determined by quantifying immunoreactive exosomal CD63 and placenta-specific marker (PLAP), respectively. The effect of exosomes isolated from FT, ST and TT on endothelial cell migration were established using a real-time, live-cell imaging system (Incucyte). Exosome plasma concentration was more than 50-fold greater in pregnant women than in non-pregnant women (p<0.001). During normal healthy pregnancy, the number of exosomes present in maternal plasma increased significantly with gestational age by more that two-fold (p<0.001). Exosomes isolated from FT, ST and TT increased endothelial cell migration by 1.9±0.1, 1.6±0.2 and 1.3±0.1-fold, respectively compared to the control. Pregnancy is associated with a dramatic increase in the number of exosomes present in plasma and maternal plasma exosomes are bioactive. While the role of placental cell-derived exosome in regulating maternal and/or fetal vascular responses remains to be elucidated, changes in exosome profile may be of clinical utility in the diagnosis of placental dysfunction. PMID:24905832

  18. Development of a Dual Plasma Desorption/Ionization System for the Noncontact and Highly Sensitive Analysis of Surface Adhesive Compounds

    PubMed Central

    Aida, Mari; Iwai, Takahiro; Okamoto, Yuki; Kohno, Satoshi; Kakegawa, Ken; Miyahara, Hidekazu; Seto, Yasuo; Okino, Akitoshi

    2017-01-01

    We developed a dual plasma desorption/ionization system using two plasmas for the semi-invasive analysis of compounds on heat-sensitive substrates such as skin. The first plasma was used for the desorption of the surface compounds, whereas the second was used for the ionization of the desorbed compounds. Using the two plasmas, each process can be optimized individually. A successful analysis of phenyl salicylate and 2-isopropylpyridine was achieved using the developed system. Furthermore, we showed that it was possible to detect the mass signals derived from a sample even at a distance 50 times greater than the distance from the position at which the samples were detached. In addition, to increase the intensity of the mass signal, 0%–0.02% (v/v) of hydrogen gas was added to the base gas generated in the ionizing plasma. We found that by optimizing the gas flow rate through the addition of a small amount of hydrogen gas, it was possible to obtain the intensity of the mass signal that was 45–824 times greater than that obtained without the addition of hydrogen gas. PMID:29234573

  19. Liquid chromatography/mass spectrometry-based plasma metabolic profiling study of escitalopram in subjects with major depressive disorder.

    PubMed

    Bandu, Raju; Lee, Hyun Jeong; Lee, Hyeong Min; Ha, Tae Hyon; Lee, Heon-Jeong; Kim, Se Joo; Ha, Kyooseob; Kim, Kwang Pyo

    2018-05-01

    Liquid chromatography-mass spectrometry (LC-MS) method revealed the plasma metabolite profiles in major depressive disorder patients treated with escitalopram (ECTP) (n = 7). Depression severity was assessed according to the 17-item Hamilton Depression Rating Scale. Metabolic profiles were derived from major depressive disorder subject blood samples collected after ECTP treatment. Blood plasma was separated and processed in order to effectively extract metabolites, which were then analyzed using LC-MS. We identified 19 metabolites and elucidated their structures using LC-tandem MS (LC-MS/MS) combined with elemental compositions derived from accurate mass measurements. We further used online H/D exchange experiments to verify the structural elucidations of each metabolite. Identifying molecular metabolites may provide critical insights into the pharmacological and clinical effects of ECTP treatment and may also provide useful information informing the development of new antidepressant treatments. These detailed plasma metabolite analyses may also be used to identify optimal dose concentrations in psychopharmacotherapeutic treatment through drug monitoring, as well as forming the basis for response predictions in depressed subjects. Copyright © 2018 John Wiley & Sons, Ltd.

  20. Synthesis, Consolidation and Characterization of Sol-gel Derived Tantalum-Tungsten Oxide Thermite Composites

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cervantes, O

    2010-06-01

    Energetic composite powders consisting of sol-gel (SG) derived nanostructured tungsten oxide were produced with various amounts of micrometer-scale tantalum fuel metal. Such energetic composite powders were ignition-tested and results show that the powders are not sensitive to friction, spark and/or impact ignition. Initial consolidation experiments, using the High Pressure Spark Plasma Sintering (HPSPS) technique, on the SG derived nanostructured tungsten oxide produced samples with higher relative density than can be achieved with commercially available tungsten oxide. The SG derived nanostructured tungsten oxide with immobilized tantalum fuel metal (Ta - WO3) energetic composite was consolidated to a density of 9.17 g·cm-3more » or 93% relative density. In addition, those samples were consolidated without significant pre-reaction of the constituents, thus retaining their stored chemical energy.« less

  1. Dependence of nanomechanical modification of polymers on plasma-induced cross-linking

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tajima, S.; Komvopoulos, K.

    2007-01-01

    The nanomechanical properties of low-density polyethylene (LDPE) modified by inductively coupled, radio-frequency Ar plasma were investigated by surface force microscopy. The polymer surface was modified under plasma conditions of different ion energy fluences and radiation intensities obtained by varying the sample distance from the plasma power source. Nanoindentation results of the surface stiffness versus maximum penetration depth did not reveal discernible differences between untreated and plasma-treated LDPE, presumably due to the small thickness of the modified surface layer that resulted in a substrate effect. On the contrary, nanoscratching experiments demonstrated a significant increase in the surface shear resistance of plasma-modifiedmore » LDPE due to chain cross-linking. These experiments revealed an enhancement of cross-linking with increasing ion energy fluence and radiation intensity, and a tip size effect on the friction force and dominant friction mechanisms (adhesion, plowing, and microcutting). In addition, LDPE samples with a LiF crystal shield were exposed to identical plasma conditions to determine the role of vacuum ultraviolet (VUV) and ultraviolet (UV) radiation in the cross-linking process. The cross-linked layer of plasma-treated LDPE exhibited much higher shear strength than that of VUV/UV-treated LDPE. Plasma-induced surface modification of the nanomechanical properties of LDPE is interpreted in the context of molecular models of the untreated and cross-linked polymer surfaces derived from experimental findings.« less

  2. Method for determining the concentration of atomic species in gases and solids

    DOEpatents

    Loge, Gary W.

    1999-01-01

    Method for determining the concentration of atomic species in gases and solids. Measurement of at least two emission intensities from a species in a plasma containing the species after a sufficient time period has elapsed after the generation of the plasma and during a second time period, permits an instantaneous temperature to be established within the sample. The concentration of the atomic species to be determined is then derived from the known emission intensity of a predetermined concentration of that species in the sample at the measured temperature, a quantity which is measured prior to the determination of the unknown concentration, and the actual measured emission from the unknown species, or by this latter emission and the emission intensity of a species having known concentration within the sample.

  3. Effect of novel water soluble curcumin derivative on experimental type- 1 diabetes mellitus (short term study)

    PubMed Central

    2012-01-01

    Background Diabetes mellitus type 1 is an autoimmune disorder caused by lymphocytic infiltration and beta cells destruction. Curcumin has been identified as a potent inducer of heme-oxygenase-1 (HO-1), a redoxsensitive inducible protein that provides protection against various forms of stress. A novel water soluble curcumin derivative (NCD) has been developed to overcome low in vivo bioavailability of curcumin. The aim of the present work is to evaluate the anti diabetic effects of the “NCD” and its effects on diabetes-induced ROS generation and lipid peroxidation in experimental type- 1 diabetes mellitus. We also examine whether the up regulation of HO-1 accompanied by increased HO activity mediates these antidiabetic and anti oxidant actions. Materials and methods Rats were divided into control group, control group receiving curcumin derivative, diabetic group, diabetic group receiving curcumin derivative and diabetic group receiving curcumin derivative and HO inhibitor ZnPP. Type-1 diabetes was induced by intraperitoneal injection of streptozotocin. Curcumin derivative was given orally for 45 days. At the planned sacrification time (after 45 days), fasting blood samples were withdrawn for estimation of plasma glucose, plasma insulin and lipid profile . Animals were sacrificed; pancreas, aorta and liver were excised for the heme oxygenase - 1 expression, activity and malondialdehyde estimation. Results NCD supplementation to diabetic rats significantly lowered the plasma glucose by 27.5% and increased plasma insulin by 66.67%. On the other hand, the mean plasma glucose level in the control group showed no significant difference compared to the control group receiving the oral NCD whereas, NCD supplementation to the control rats significantly increased the plasma insulin by 47.13% compared to the control. NCD decreased total cholesterol, triglycerides, LDL cholesterol and increased HDL cholesterol levels. Also, it decreased lipid peroxides (malondialdehyde) in the pancreas, aorta and liver. Conclusion The (NCD) by its small dose possesses antidiabetic actions and that heme oxygenase induction seems to play an important role in its anti-diabetic effects. NCD also improves the lipid profile and oxidative status directly, proved by decreasing lipid peroxides (malondialdehyde) in pancreas, liver & aorta. The new water soluble curcumin derivative still retains the essential potencies of natural curcumin. PMID:22762693

  4. Using dried blood spot sampling to improve data quality and reduce animal use in mouse pharmacokinetic studies.

    PubMed

    Wickremsinhe, Enaksha R; Perkins, Everett J

    2015-03-01

    Traditional pharmacokinetic analysis in nonclinical studies is based on the concentration of a test compound in plasma and requires approximately 100 to 200 μL blood collected per time point. However, the total blood volume of mice limits the number of samples that can be collected from an individual animal-often to a single collection per mouse-thus necessitating dosing multiple mice to generate a pharmacokinetic profile in a sparse-sampling design. Compared with traditional methods, dried blood spot (DBS) analysis requires smaller volumes of blood (15 to 20 μL), thus supporting serial blood sampling and the generation of a complete pharmacokinetic profile from a single mouse. Here we compare plasma-derived data with DBS-derived data, explain how to adopt DBS sampling to support discovery mouse studies, and describe how to generate pharmacokinetic and pharmacodynamic data from a single mouse. Executing novel study designs that use DBS enhances the ability to identify and streamline better drug candidates during drug discovery. Implementing DBS sampling can reduce the number of mice needed in a drug discovery program. In addition, the simplicity of DBS sampling and the smaller numbers of mice needed translate to decreased study costs. Overall, DBS sampling is consistent with 3Rs principles by achieving reductions in the number of animals used, decreased restraint-associated stress, improved data quality, direct comparison of interanimal variability, and the generation of multiple endpoints from a single study.

  5. Using Dried Blood Spot Sampling to Improve Data Quality and Reduce Animal Use in Mouse Pharmacokinetic Studies

    PubMed Central

    Wickremsinhe, Enaksha R; Perkins, Everett J

    2015-01-01

    Traditional pharmacokinetic analysis in nonclinical studies is based on the concentration of a test compound in plasma and requires approximately 100 to 200 µL blood collected per time point. However, the total blood volume of mice limits the number of samples that can be collected from an individual animal—often to a single collection per mouse—thus necessitating dosing multiple mice to generate a pharmacokinetic profile in a sparse-sampling design. Compared with traditional methods, dried blood spot (DBS) analysis requires smaller volumes of blood (15 to 20 µL), thus supporting serial blood sampling and the generation of a complete pharmacokinetic profile from a single mouse. Here we compare plasma-derived data with DBS-derived data, explain how to adopt DBS sampling to support discovery mouse studies, and describe how to generate pharmacokinetic and pharmacodynamic data from a single mouse. Executing novel study designs that use DBS enhances the ability to identify and streamline better drug candidates during drug discovery. Implementing DBS sampling can reduce the number of mice needed in a drug discovery program. In addition, the simplicity of DBS sampling and the smaller numbers of mice needed translate to decreased study costs. Overall, DBS sampling is consistent with 3Rs principles by achieving reductions in the number of animals used, decreased restraint-associated stress, improved data quality, direct comparison of interanimal variability, and the generation of multiple endpoints from a single study. PMID:25836959

  6. Determination of tetrabromobisphenol-A/S and their main derivatives in water samples by high performance liquid chromatography coupled with inductively coupled plasma tandem mass spectrometry.

    PubMed

    Liu, Lihong; Liu, Aifeng; Zhang, Qinghua; Shi, Jianbo; He, Bin; Yun, Zhaojun; Jiang, Guibin

    2017-05-12

    As the most widely used brominated flame retardants (BFRs), Tetrabromobisphenol-A (TBBPA) as well as its alternative Tetrabromobisphenol-S (TBBPS) and their derivatives have raised wide concerns due to their adverse effects on human health and hence the sensitive detection of those BFRs was urgently needed. Herein, a novel analytical method based on high-performance liquid chromatography (HPLC) coupled with inductively coupled plasma tandem mass spectrometry (ICP-MS/MS) has been developed for the determination of TBBPA/S and their derivatives, including TBBPA-bis(2-hydroxyethyl ether) (TBBPA-BHEE), TBBPA-bis(allylether) (TBBPA-BAE), TBBPA-bis(glycidyl ether) (TBBPA-BGE), TBBPA-bis(2,3-dibromopropyl ether) (TBBPA-BDBPE) and TBBPS-bis(2,3-dibromopropyl ether) (TBBPS-BDBPE) in water samples. After optimization, the TBBPA/S and their derivatives, especially the TBBPA-BAE and TBBPA-BDBPE were simultaneously and sensitively quantified by determination of bromine (m/z=79) by using the ICP-MS. The instrument limits of detection (LODs) for the TBBPA, TBBPA-BHEE, TBBPA-BGE, TBBPA-BAE, TBBPA-BDBPE, TBBPS and TBBPS-BDBPE were determined to be 0.12, 0.14, 0.19, 0.14, 0.12, 0.17 and 0.13μgL -1 , respectively, which was close to or much better than the reported methods. The relative standard deviations (RSDs, n=5) of peak area and retention time were better than 2.2% and 0.2% for intra-day analysis, indicating good repeatability and high precision. The proposed method had been successfully applied for the analysis of TBBPA/S and their derivatives in water samples with satisfactory recoveries (67.7%-113%). Copyright © 2017 Elsevier B.V. All rights reserved.

  7. Basic characteristics of plasma rich in growth factors (PRGF): blood cell components and biological effects.

    PubMed

    Nishiyama, Kazuhiko; Okudera, Toshimitsu; Watanabe, Taisuke; Isobe, Kazushige; Suzuki, Masashi; Masuki, Hideo; Okudera, Hajime; Uematsu, Kohya; Nakata, Koh; Kawase, Tomoyuki

    2016-11-01

    Platelet-rich plasma (PRP) is widely used in regenerative medicine because of its high concentrations of various growth factors and platelets. However, the distribution of blood cell components has not been investigated in either PRP or other PRP derivatives. In this study, we focused on plasma rich in growth factors (PRGF), a PRP derivative, and analyzed the distributions of platelets and white blood cells (WBCs). Peripheral blood samples were collected from healthy volunteers ( N  = 14) and centrifuged to prepare PRGF and PRP. Blood cells were counted using an automated hematology analyzer. The effects of PRP and PRGF preparations on cell proliferation were determined using human periosteal cells. In the PRGF preparations, both red blood cells and WBCs were almost completely eliminated, and platelets were concentrated by 2.84-fold, whereas in the PRP preparations, both platelets and WBCs were similarly concentrated by 8.79- and 5.51-fold, respectively. Platelet counts in the PRGF preparations were positively correlated with platelet counts in the whole blood samples, while the platelet concentration rate was negatively correlated with red blood cell counts in the whole blood samples. In contrast, platelet counts and concentration rates in the PRP preparations were significantly influenced by WBC counts in whole blood samples. The PRP preparations, but not the PRGF preparations, significantly suppressed cell growth at higher doses in vitro. Therefore, these results suggest that PRGF preparations can clearly be distinguished from PRP preparations by both inclusion of WBCs and dose-dependent stimulation of periosteal cell proliferation in vitro.

  8. Basic characteristics of plasma rich in growth factors (PRGF): blood cell components and biological effects

    PubMed Central

    Nishiyama, Kazuhiko; Okudera, Toshimitsu; Watanabe, Taisuke; Isobe, Kazushige; Suzuki, Masashi; Masuki, Hideo; Okudera, Hajime; Uematsu, Kohya; Nakata, Koh

    2016-01-01

    Abstract Platelet‐rich plasma (PRP) is widely used in regenerative medicine because of its high concentrations of various growth factors and platelets. However, the distribution of blood cell components has not been investigated in either PRP or other PRP derivatives. In this study, we focused on plasma rich in growth factors (PRGF), a PRP derivative, and analyzed the distributions of platelets and white blood cells (WBCs). Peripheral blood samples were collected from healthy volunteers (N = 14) and centrifuged to prepare PRGF and PRP. Blood cells were counted using an automated hematology analyzer. The effects of PRP and PRGF preparations on cell proliferation were determined using human periosteal cells. In the PRGF preparations, both red blood cells and WBCs were almost completely eliminated, and platelets were concentrated by 2.84‐fold, whereas in the PRP preparations, both platelets and WBCs were similarly concentrated by 8.79‐ and 5.51‐fold, respectively. Platelet counts in the PRGF preparations were positively correlated with platelet counts in the whole blood samples, while the platelet concentration rate was negatively correlated with red blood cell counts in the whole blood samples. In contrast, platelet counts and concentration rates in the PRP preparations were significantly influenced by WBC counts in whole blood samples. The PRP preparations, but not the PRGF preparations, significantly suppressed cell growth at higher doses in vitro. Therefore, these results suggest that PRGF preparations can clearly be distinguished from PRP preparations by both inclusion of WBCs and dose‐dependent stimulation of periosteal cell proliferation in vitro. PMID:29744155

  9. Chinese plasma-derived products supply under the lot release management system in 2007-2011.

    PubMed

    Zhang, Xuejun; Ye, Shengliang; Du, Xi; Yuan, Jing; Zhao, Chaoming; Li, Changqing

    2013-11-01

    In 2007, the Chinese State Food and Drug Administration (SFDA) implemented a management system for lot release of all plasma-derived products. Since then, there have been only a few systematic studies of the blood supply, which is a concern when considering the small amount of plasma collected per capita (approximately 3 L/1000 people). As a result, there may be a threat to the safety of the available blood supply. In this study, we examined the characteristics of the supply of Chinese plasma-derived products. We investigated the reports of lot-released biological products derived from all 8 national or regional regulatory authorities in China from 2007 to 2011. The market supply characteristics of Chinese plasma-derived products were analyzed by reviewing the changes in supply varieties, the batches of lot-released plasma-derived products and the actual supply. As a result, the national regulatory authorities can more accurately develop a specific understanding of the production and quality management information provided by Chinese plasma product manufacturers. The implementation of the lot release system further ensures the clinical validity of the plasma-derived products in China and improves the safety of using plasma-derived products. This work provides an assessment of the future Chinese market supply of plasma-derived products and can function as a theoretical basis for the establishment of hemovigilance. Copyright © 2013 The International Alliance for Biological Standardization. Published by Elsevier Ltd. All rights reserved.

  10. Quantification of vosaroxin and its metabolites N-desmethylvosaroxin and O-desmethylvosaroxin in human plasma and urine using high-performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Nijenhuis, C M; Lucas, L; Rosing, H; Jamieson, G; Fox, J A; Schellens, J H M; Beijnen, J H

    2016-08-01

    Vosaroxin is a first-in-class anticancer quinolone derivative topoisomerase II inhibitor that is currently in development in combination with cytarabine for the treatment of acute myeloid leukemia (AML). To investigate vosaroxin pharmacokinetics (PK) in patients, liquid chromatography tandem mass spectrometry (LC-MS/MS) assays to quantify vosaroxin and the two metabolites N-desmethylvosaroxin and O-desmethylvosaroxin in human plasma and urine were developed and validated. Immediately after collection the samples were stored at -80°C. Prior to analysis, the plasma samples were subjected to protein precipitation and the urine samples were diluted. For both assays the reconstituted extracts were injected on a Symmetry Shield RP8 column and gradient elution was applied using 0.1% formic acid in water and acetonitrile-methanol (50:50, v/v). Analyses were performed with a triple quadruple mass spectrometer in positive-ion mode. A deuterated isotope of vosaroxin was used as internal standard for the quantification. The validated assays quantify vosaroxin and N-desmethylvosaroxin in the concentration range of 2-500ng/mL in plasma and urine. For O-desmethylvosaroxin the concentration range of 4-500ng/mL in plasma and urine was validated. Dilution integrity experiments show that samples can be diluted 25 fold in control matrix prior to analysis. The expanded concentration range for plasma and urine for vosaroxin and N-desmethylvosaroxin is therefore from 2 to 15,000ng/mL and in plasma for O-desmethylvosaroxin from 4 to 15,000ng/mL. Copyright © 2016 Elsevier B.V. All rights reserved.

  11. Validation of an HPLC method for the determination of urinary and plasma levels of N1-methylnicotinamide, an endogenous marker of renal cationic transport and plasma flow.

    PubMed

    Musfeld, C; Biollaz, J; Bélaz, N; Kesselring, U W; Decosterd, L A

    2001-01-01

    N1-Methylnicotinamide (NMN) is an endogenous cationic metabolite of nicotinamide (niacine, vitamine PP) whose renal clearance reflects both the capacity of the renal tubular transport system to secrete organic cations and renal plasma flow. NMN is present in human plasma and urine at the 1-117-ng ml(-1) and 0.5-25-microg ml(-1) concentration range, respectively, and its level depends notably on pathophysiological (age, renal or hepatic diseases) conditions. We report the optimization and validation of an HPLC method for the measurement of endogenous NMN in biological fluids after derivatization into a fluorescent compound. Plasma is first deproteinized with TCA 20% and the urine diluted 1:10 with HCI 10(-4) M prior to the derivatization procedure, which includes a condensation reaction of NMN with acetophenone in NaOH at 0 degrees C, followed by dehydration in formic acid and subsequent formation of the fluorescent 1,6-naphthyridine derivatives after heating samples in a boiling water bath. The synthetic homologous derivative N1-ethylnicotinamide (NEN) reacts similarly and is added as internal standard into the biological fluid. The reaction mixture is subjected to reverse phase high performance liquid chromatography on a Nucleosil 100-C18 column using a mobile phase (acetonitrile 22%, triethylamine 0.5%, 0.01 M sodium heptanesulfonate adjusted to pH 3.2), delivered isocratically at a flow rate of 1 ml min(-1), NMN and NEN are detected at 7.8 and 10 min by spectrofluorimetry with excitation and emission wavelengths set at 366 and 418 nm, respectively. The addition-calibration method is used with plasma and urine pools. Calibration curves (using the internal standard method) are linear (r2 > 0.997) at concentrations up to 109 ng ml(-1) and 15.7 microg ml(-1) in plasma and urine, respectively. Both intra- and inter-assay precision of plasma control samples at 10, 50 and 90 ng ml(-1) were lower than 3.3% and concentrations not deviating more than 2.7% from their nominal values. In urine intra- and inter-assay CVs of control samples at 1, 5 and 9 microg ml(-1) are lower than 8.3%, with concentrations not deviating more than -9.0 to +11.8% from their nominal values. This analytical method has therefore the required sensitivity and selectivity to measure NMN in plasma and urine, enabling the non-invasive determination of the tubular secretory capacity of the kidney and the renal plasma flow.

  12. Enfuvirtide cerebrospinal fluid (CSF) pharmacokinetics and potential use in defining CSF HIV-1 origin.

    PubMed

    Price, Richard W; Parham, Robin; Kroll, Jing Lu; Wring, Stephen A; Baker, Brian; Sailstad, Jeff; Hoh, Rebecca; Liegler, Teri; Spudich, Serena; Kuritzkes, Daniel R; Deeks, Steven G

    2008-01-01

    Enfuvirtide is a potent inhibitor of systemic HIV-1 replication, but its penetration into the human central nervous system (CNS) has not been analysed. Here, we define cerebrospinal fluid (CSF) enfuvirtide pharmacokinetics and present a case illustrating the use of enfuvirtide as a probe to trace the origins of CSF HIV-1 quasispecies. Enfuvirtide CSF pharmacokinetics were assessed in 18 CSF and plasma sample pairs from four HIV-1-infected individuals. Enfuvirtide levels were measured by liquid chromatography tandem mass spectrometry using known standards and controls that included spiked CSF samples from untreated, HIV-negative individuals. A segment of the gp41 coding region encompassing the heptad repeat HR-1 and HR-2 domains was amplified from selected CSF and plasma samples and independent clones sequenced to assess resistance-associated mutations. CSF and plasma samples obtained between 2 and 20 h after enfuvirtide injection showed plasma concentrations similar to previous reports (mean 3.687 SD +/- 1.828 mg/ml) with prolonged decay. By contrast, enfuvirtide in all CSF samples was below the assay detection limit of 0.025 mg/ml. In one individual, who developed a transient increase in CSF HIV-1 RNA, seven of seven CSF and plasma clones had identical enfuvirtide resistance-associated V38A mutations, suggesting that the CSF quasispecies derived from that of blood. Enfuvirtide penetration into CSF is negligible; thus, in clinical settings, where direct CNS drug exposure is crucial, this drug Is not likely to directly contribute to the local therapeutic effect. Enfuvirtide can be used as a tool to dissect the origin of the CNS virus.

  13. CancerLocator: non-invasive cancer diagnosis and tissue-of-origin prediction using methylation profiles of cell-free DNA.

    PubMed

    Kang, Shuli; Li, Qingjiao; Chen, Quan; Zhou, Yonggang; Park, Stacy; Lee, Gina; Grimes, Brandon; Krysan, Kostyantyn; Yu, Min; Wang, Wei; Alber, Frank; Sun, Fengzhu; Dubinett, Steven M; Li, Wenyuan; Zhou, Xianghong Jasmine

    2017-03-24

    We propose a probabilistic method, CancerLocator, which exploits the diagnostic potential of cell-free DNA by determining not only the presence but also the location of tumors. CancerLocator simultaneously infers the proportions and the tissue-of-origin of tumor-derived cell-free DNA in a blood sample using genome-wide DNA methylation data. CancerLocator outperforms two established multi-class classification methods on simulations and real data, even with the low proportion of tumor-derived DNA in the cell-free DNA scenarios. CancerLocator also achieves promising results on patient plasma samples with low DNA methylation sequencing coverage.

  14. A Method for Electrochemical Detection of Brain Derived Neurotrophic Factor (BDNF) in plasma.

    PubMed

    Bockaj, Marina; Fung, Barnabas; Tsoulis, Michael; Foster, Lauren Warren; Soleymani, Leyla

    2018-06-22

    Currently, a blood test for the diagnosis of endometriosis, a common estrogen-dependent gynecological disease, does not exist. Recent studies suggest that circulating concentrations of brain derived neurotrophic factor (BDNF) have potential for the diagnosis of endometriosis. However, at present BDNF can only be measured by ELISA which requires a clinic visit, a routine blood sample, and laboratory testing. Therefore, we developed a point-of-care device (EndoChip) for use with small blood volumes that can be collected through a finger prick. Specifically, the presented device is a polymer-based chip with a wrinkled nanoporous gold film acting as the electrode/sensing layer, allowing for the electrochemical detection of BDNF in plasma. Increasing concentrations of BDNF (0.25 - 2.0 ng/ml) induced significant differences in redox current. The biosensor produces a signal readout in a matter of seconds, and is ideal for realizing multiplexing. Blood samples were collected from women (n=20) with chronic pelvic pain undergoing a diagnostic laparoscopy. Plasma BDNF concentrations measured by commercial ELISA were positively correlated (r2=0.8216; p<0.001) with results from the EndoChip. Our results demonstrate a quick and reliable method for point-of-care quantification of circulating concentrations of BDNF and a promising diagnostic tool for endometriosis.

  15. Diurnal Variation of Plasma Brain-Derived Neurotrophic Factor Levels in Women with Functional Hypothalamic Amenorrhea.

    PubMed

    Drakopoulos, Panagiotis; Casarosa, Elena; Bucci, Fiorella; Piccinino, Manuela; Wenger, Jean-Marie; Nappi, Rossella Elena; Polyzos, Nicholas; Genazzani, Andrea Riccardo; Pluchino, Nicola

    2015-01-01

    Brain-derived neurotrophic factor (BDNF) is strongly related to hormonal networks and is modulated by hypothalamic activity. To evaluate plasma BDNF concentration in patients with functional hypothalamic amenorrhea (FHA), with reference to the BDNF circadian rhythm and its relation with the cortisol (F) rhythm, and to assess whether the duration of amenorrhea might influence the BDNF:F ratio in FHA. This was an observational study evaluating 36 amenorrheic and 30 eumenorrheic women. Basal values of BDNF and hormones were examined in blood samples collected from 7:00 to 9:00 h in all the women. Basal BDNF and F levels were determined in blood samples collected in 12 subjects from each group at 8:00, 12:00, 16:00, 20:00, and 24:00 h. BDNF plasma levels are significantly lower in amenorrheic women (p < 0.001) than in the follicular phase of eumenorrheic women. There are no correlations between BDNF values (p > 0.05), sex steroids, and F in FHA. Low plasma BDNF levels in FHA are not significantly correlated with duration of amenorrhea. The 24-hour variation of BDNF in amenorrheic women is significantly lower when compared to the control group, and normal daily variations of BDNF disappeared in FHA patients. F preserved its circadian rhythm in both groups. Interactions between BDNF, the hypothalamus-pituitary-adrenal axis, and sex steroids might be critical in clinical conditions of modified homeostasis/adaptation, such as FHA. © 2015 S. Karger AG, Basel.

  16. Relative bioavailability, metabolism and tolerability of rectally administered oxcarbazepine suspension.

    PubMed

    Clemens, Pamela L; Cloyd, James C; Kriel, Robert L; Remmel, Rory P

    2007-01-01

    Maintenance of effective drug concentrations is essential for adequate treatment of epilepsy. Some antiepileptic drugs can be successfully administered rectally when the oral route of administration is temporarily unavailable. Oxcarbazepine is a newer antiepileptic drug that is rapidly converted to a monohydroxy derivative, the active compound. This study aimed to characterise the bioavailability, metabolism and tolerability of rectally administered oxcarbazepine suspension using a randomised, crossover design in ten healthy volunteers. Two subjects received 300 mg doses of oxcarbazepine suspension via rectal and oral routes and eight received 450 mg doses. A washout period of at least 2 weeks elapsed between doses. The rectal dose was diluted 1:1 with water. Blood samples and urine were collected for 72 hours post-dose. Adverse effects were assessed at each blood collection time-point using a self-administered questionnaire. Plasma was assayed for oxcarbazepine and monohydroxy derivative; urine was assayed for monohydroxy derivative and monohydroxy derivative-glucuronide. Maximum plasma concentration (C(max)) and time to reach C(max) (t(max)) were obtained directly from the plasma concentration-time curves. The areas under the concentration-time curve (AUCs) were determined via non-compartmental analysis. Relative bioavailability was calculated and the C(max) and AUCs were compared using Wilcoxon signed-rank tests. Mean relative bioavailability calculated from plasma AUCs was 8.3% (SD 5.5%) for the monohydroxy derivative and 10.8% (SD 7.3%) for oxcarbazepine. Oxcarbazepine and monohydroxy derivative C(max) and AUC values were significantly lower following rectal administration (p < 0.01). The total amount of monohydroxy derivative excreted in the urine following rectal administration was 10 +/- 5% of the amount excreted following oral administration. Oral absorption was consistent with previous studies. The most common adverse effects were headache and fatigue with no discernible differences between routes. Monohydroxy derivative bioavailability following rectal administration of oxcarbazepine suspension is significantly lower than following oral administration, most likely because of poor oxcarbazepine water solubility. It is unlikely that adequate monohydroxy derivative concentrations can be achieved with rectal administration of diluted oxcarbazepine suspension.

  17. Increased levels of circulating microparticles are associated with increased procoagulant activity in patients with cutaneous malignant melanoma.

    PubMed

    Laresche, Claire; Pelletier, Fabien; Garnache-Ottou, Francine; Lihoreau, Thomas; Biichlé, Sabeha; Mourey, Guillaume; Saas, Philippe; Humbert, Philippe; Seilles, Estelle; Aubin, François

    2014-01-01

    Microparticles (MPs) are known to be increased in various malignancies and are involved in tumor invasion, angiogenesis, coagulation, and metastasis. We investigated the plasma levels of annexin-V MPs (AV(+)MPs), platelet-derived MPs (PMPs), and endothelial-derived MPs (EMPs) in patients with melanoma (n=129) and in healthy controls (n=49). A functional coagulation test STA Procoag-PPL measuring the clotting time was performed on samples containing MPs to evaluate their procoagulant potential. The plasma levels of PMPs, EMPs, and AV(+)MPs were significantly higher, and the clotting time-PPL was significantly lower in melanoma patients than in healthy controls. The plasma levels of PMPs, EMPs, and AV(+)MPs were higher in stage IV than in the other stages of melanoma, but with no significant difference. In addition, we observed an inverse correlation between PMPs, AV(+)MPs, and clotting times. Our data suggest that MPs are involved in the progression of melanoma and may be associated to melanoma-associated thrombogenesis.

  18. Identification and MS-assisted interpretation of genetically influenced NMR signals in human plasma

    PubMed Central

    2013-01-01

    Nuclear magnetic resonance spectroscopy (NMR) provides robust readouts of many metabolic parameters in one experiment. However, identification of clinically relevant markers in 1H NMR spectra is a major challenge. Association of NMR-derived quantities with genetic variants can uncover biologically relevant metabolic traits. Using NMR data of plasma samples from 1,757 individuals from the KORA study together with 655,658 genetic variants, we show that ratios between NMR intensities at two chemical shift positions can provide informative and robust biomarkers. We report seven loci of genetic association with NMR-derived traits (APOA1, CETP, CPS1, GCKR, FADS1, LIPC, PYROXD2) and characterize these traits biochemically using mass spectrometry. These ratios may now be used in clinical studies. PMID:23414815

  19. Analytical validation of BRAF mutation testing from circulating free DNA using the amplification refractory mutation testing system.

    PubMed

    Aung, Kyaw L; Donald, Emma; Ellison, Gillian; Bujac, Sarah; Fletcher, Lynn; Cantarini, Mireille; Brady, Ged; Orr, Maria; Clack, Glen; Ranson, Malcolm; Dive, Caroline; Hughes, Andrew

    2014-05-01

    BRAF mutation testing from circulating free DNA (cfDNA) using the amplification refractory mutation testing system (ARMS) holds potential as a surrogate for tumor mutation testing. Robust assay validation is needed to establish the optimal clinical matrix for measurement and cfDNA-specific mutation calling criteria. Plasma- and serum-derived cfDNA samples from 221 advanced melanoma patients were analyzed for BRAF c.1799T>A (p.V600E) mutation using ARMS in two stages in a blinded fashion. cfDNA-specific mutation calling criteria were defined in stage 1 and validated in stage 2. cfDNA concentrations in serum and plasma, and the sensitivities and specificities of BRAF mutation detection in these two clinical matrices were compared. Sensitivity of BRAF c.1799T>A (p.V600E) mutation detection in cfDNA was increased by using mutation calling criteria optimized for cfDNA (these criteria were adjusted from those used for archival tumor biopsies) without compromising specificity. Sensitivity of BRAF mutation detection in serum was 44% (95% CI, 35% to 53%) and in plasma 52% (95% CI, 43% to 61%). Specificity was 96% (95% CI, 90% to 99%) in both matrices. Serum contains significantly higher total cfDNA than plasma, whereas the proportion of tumor-derived mutant DNA was significantly higher in plasma. Using mutation calling criteria optimized for cfDNA improves sensitivity of BRAF c.1799T>A (p.V600E) mutation detection. The proportion of tumor-derived cfDNA in plasma was significantly higher than in serum. Copyright © 2014 American Society for Investigative Pathology and the Association for Molecular Pathology. Published by Elsevier Inc. All rights reserved.

  20. A Simple Plasma Retinol Isotope Ratio Method for Estimating β-Carotene Relative Bioefficacy in Humans: Validation with the Use of Model-Based Compartmental Analysis.

    PubMed

    Ford, Jennifer Lynn; Green, Joanne Balmer; Lietz, Georg; Oxley, Anthony; Green, Michael H

    2017-09-01

    Background: Provitamin A carotenoids are an important source of dietary vitamin A for many populations. Thus, accurate and simple methods for estimating carotenoid bioefficacy are needed to evaluate the vitamin A value of test solutions and plant sources. β-Carotene bioefficacy is often estimated from the ratio of the areas under plasma isotope response curves after subjects ingest labeled β-carotene and a labeled retinyl acetate reference dose [isotope reference method (IRM)], but to our knowledge, the method has not yet been evaluated for accuracy. Objectives: Our objectives were to develop and test a physiologically based compartmental model that includes both absorptive and postabsorptive β-carotene bioconversion and to use the model to evaluate the accuracy of the IRM and a simple plasma retinol isotope ratio [(RIR), labeled β-carotene-derived retinol/labeled reference-dose-derived retinol in one plasma sample] for estimating relative bioefficacy. Methods: We used model-based compartmental analysis (Simulation, Analysis and Modeling software) to develop and apply a model that provided known values for β-carotene bioefficacy. Theoretical data for 10 subjects were generated by the model and used to determine bioefficacy by RIR and IRM; predictions were compared with known values. We also applied RIR and IRM to previously published data. Results: Plasma RIR accurately predicted β-carotene relative bioefficacy at 14 d or later. IRM also accurately predicted bioefficacy by 14 d, except that, when there was substantial postabsorptive bioconversion, IRM underestimated bioefficacy. Based on our model, 1-d predictions of relative bioefficacy include absorptive plus a portion of early postabsorptive conversion. Conclusion: The plasma RIR is a simple tracer method that accurately predicts β-carotene relative bioefficacy based on analysis of one blood sample obtained at ≥14 d after co-ingestion of labeled β-carotene and retinyl acetate. The method also provides information about the contributions of absorptive and postabsorptive conversion to total bioefficacy if an additional sample is taken at 1 d. © 2017 American Society for Nutrition.

  1. Naturally occurring anti-glycan antibodies binding to Globo H-expressing cells identify ovarian cancer patients.

    PubMed

    Pochechueva, Tatiana; Alam, Shahidul; Schötzau, Andreas; Chinarev, Alexander; Bovin, Nicolai V; Hacker, Neville F; Jacob, Francis; Heinzelmann-Schwarz, Viola

    2017-02-10

    Glycosphingolipids are important compounds of the plasma membrane of mammalian cells and a number of them have been associated with malignant transformation and progression, reinforcing tumour aggressiveness and metastasis. Here we investigated the levels of naturally occurring anti-glycan antibodies to Globo H in blood plasma obtained from high-grade serous ovarian cancer patients (SOC) and women without gynaecological malignancies (control) using suspension glycan array technology employing chemically synthesized glycans as antibody targets. We found that anti-human Globo H IgG antibodies were able to significantly discriminate SOC from controls (P < 0.05). A combination with the clinically used tumour marker CA125 increased the diagnostic performance (AUC 0.8711). We next compared suspension array with standard flow cytometry in plasma samples and found that the level of anti-Globo H antibodies highly correlated (r = 0.992). The incubation of plasma-derived anti-glycan antibodies with chemically synthesized (presented on fluorescence microspheres) and native Globo H (expressed on Globo H-positive cell lines) revealed strong reactivity of naturally occurring human anti-Globo H antibodies towards its antigen expressed on ovarian cancer cells. Our data demonstrate that human plasma-derived antibodies to Globo H as well as the presence of the antigen might be considered as therapeutic option in ovarian cancer.

  2. Unsuccessful Detection of Plant MicroRNAs in Beer, Extra Virgin Olive Oil and Human Plasma After an Acute Ingestion of Extra Virgin Olive Oil.

    PubMed

    Micó, Victor; Martín, Roberto; Lasunción, Miguel A; Ordovás, Jose M; Daimiel, Lidia

    2016-03-01

    The recent description of the presence of exogenous plant microRNAs from rice in human plasma had profound implications for the interpretation of microRNAs function in human health. If validated, these results suggest that food should not be considered only as a macronutrient and micronutrient supplier but it could also be a way of genomic interchange between kingdoms. Subsequently, several studies have tried to replicate these results in rice and other plant foods and most of them have failed to find plant microRNAs in human plasma. In this scenario, we aimed to detect plant microRNAs in beer and extra virgin olive oil (EVOO)--two plant-derived liquid products frequently consumed in Spain--as well as in human plasma after an acute ingestion of EVOO. Our hypothesis was that microRNAs present in beer and EVOO raw material could survive manufacturing processes, be part of these liquid products, be absorbed by human gut and circulate in human plasma. To test this hypothesis, we first optimized the microRNA extraction protocol to extract microRNAs from beer and EVOO, and then tried to detect microRNAs in those samples and in plasma samples of healthy volunteers after an acute ingestion of EVOO.

  3. One should avoid retro-orbital pharmacokinetic sample collections for intranasal dosing in rats: Illustration of spurious pharmacokinetics generated for anti-migraine drugs zolmitriptan and eletriptan.

    PubMed

    Patel, Harilal; Patel, Prakash; Modi, Nirav; Shah, Shaival; Ghoghari, Ashok; Variya, Bhavesh; Laddha, Ritu; Baradia, Dipesh; Dobaria, Nitin; Mehta, Pavak; Srinivas, Nuggehally R

    2017-08-30

    Because of the avoidance of first pass metabolic effects due to direct and rapid absorption with improved permeability, intranasal route represents a good alternative for extravascular drug administration. The aim of the study was to investigate the intranasal pharmacokinetics of two anti-migraine drugs (zolmitriptan and eletriptan), using retro-orbital sinus and jugular vein sites sampling. In a parallel study design, healthy male Sprague-Dawley (SD) rats aged between 8 and 12weeks were divided into groups (n=4 or 5/group). The animals of individual groups were dosed intranasal (~1.0mg/kg) and oral doses of 2.1mg/kg of either zolmitriptan or eletriptan. Serial blood sampling was performed from jugular vein or retro-orbital site and plasma samples were analyzed for drug concentrations using LC-MS/MS assay. Standard pharmacokinetics parameters such as T max , C max , AUC last , AUC 0-inf and T 1/2 were calculated and statistics of derived parameters was performed using unpaired t-test. After intranasal dosing, the mean pharmacokinetic parameters C max and AUC inf of zolmitriptan/eletriptan showed about 17-fold and 3-5-fold higher values for retro-orbital sampling as compared to the jugular vein sampling site. Whereas after oral administration such parameters derived for both drugs were largely comparable between the two sampling sites and statistically non-significant. In conclusion, the assessment of plasma levels after intranasal administration with retro-orbital sampling would result in spurious and misleading pharmacokinetics. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. Measurement of free and bound malondialdehyde in plasma by high-performance liquid chromatography as the 2,4-dinitrophenylhydrazine derivative.

    PubMed

    Pilz, J; Meineke, I; Gleiter, C H

    2000-06-09

    We established a method for the detection of free and total (free and bound) malondialdehyde (MDA) in human plasma samples after derivatisation with 2,4-dinitrophenylhydrazine (DNPH). Free MDA was prepared by perchloric acid deproteinisation whereas an alkaline hydrolysation step for 30 min at 60 degrees C was introduced prior to protein precipitation for the determination of total MDA. Derivatisation was accomplished in 10 min at room temperature subsequently chromatographed by HPLC on a reversed-phase 3 microm C(18) column with UV detection (310 nm). The detection limit was 25 pmol/ml for free and 0.3 nmol/ml for total MDA. The recovery of MDA added to different human plasma samples was 93.6% (n=11; RSD 7.1%) for the hydrolysation procedure. In samples from 12 healthy volunteers who underwent a hypoxic treatment (13% O2 for 6 h) we estimated a baseline value of total MDA of 2.16 nmol/ml (SD 0.29) (ambient air) with a significant increase to 2.92 (nmol/ml, SD 0.57; P=0.01) after the end of this physiological oxidative stress challenge. Plasma values of free MDA in these samples were close to our detection limit. The presented technique can easily performed with an isocratic HPLC apparatus and provides highly specific results for MDA as do sophisticated GC-MS methods.

  5. Green tea catechins and their metabolites in human skin before and after exposure to ultraviolet radiation.

    PubMed

    Clarke, Kayleigh A; Dew, Tristan P; Watson, Rachel E B; Farrar, Mark D; Osman, Joanne E; Nicolaou, Anna; Rhodes, Lesley E; Williamson, Gary

    2016-01-01

    Dietary flavonoids may protect against sunburn inflammation in skin. Preliminary reports using less complete analysis suggest that certain catechins and their metabolites are found in skin biopsies and blister fluid after consumption of green tea; however, it is not known if they are affected by solar-simulated ultraviolet radiation (UVR) or whether conjugated forms, with consequently altered bioactivity, are present. The present study tested the hypothesis that UVR affects the catechin levels in the skin of healthy volunteers after consumption of green tea and how catechins in the plasma are related to their presence in skin tissue samples. In an open oral intervention study, 11 subjects consumed green tea and vitamin C supplements daily for 3months. Presupplementation and postsupplementation plasma samples, suction blister fluid and skin biopsies were collected; the latter two samples were collected both before and after UVR. A sensitive high-performance liquid chromatography/mass spectrometric assay was used to measure the intact catechin metabolites, conjugates and free forms. Seven green tea catechins and their corresponding metabolites were identified postsupplementation in skin biopsies, 20 in blister fluid and 26 in plasma, with 15 green tea catechin metabolites present in both blister fluid and plasma. The valerolactone, O-methyl-M4-O-sulfate, a gut microbiota metabolite of catechins, was significantly increased 1.6-fold by UVR in blister fluid samples. In conclusion, there were some common catechin metabolites in the plasma and blister fluid, and the concentration was always higher in plasma. The results suggest that green tea catechins and metabolites are bioavailable in skin and provide a novel link between catechin metabolites derived from the skin and gut microbiota. Copyright © 2015 The Authors. Published by Elsevier Inc. All rights reserved.

  6. Green tea catechins and their metabolites in human skin before and after exposure to ultraviolet radiation☆☆☆★

    PubMed Central

    Clarke, Kayleigh A.; Dew, Tristan P.; Watson, Rachel E.B.; Farrar, Mark D.; Osman, Joanne E.; Nicolaou, Anna; Rhodes, Lesley E.; Williamson, Gary

    2016-01-01

    Dietary flavonoids may protect against sunburn inflammation in skin. Preliminary reports using less complete analysis suggest that certain catechins and their metabolites are found in skin biopsies and blister fluid after consumption of green tea; however, it is not known if they are affected by solar-simulated ultraviolet radiation (UVR) or whether conjugated forms, with consequently altered bioactivity, are present. The present study tested the hypothesis that UVR affects the catechin levels in the skin of healthy volunteers after consumption of green tea and how catechins in the plasma are related to their presence in skin tissue samples. In an open oral intervention study, 11 subjects consumed green tea and vitamin C supplements daily for 3 months. Presupplementation and postsupplementation plasma samples, suction blister fluid and skin biopsies were collected; the latter two samples were collected both before and after UVR. A sensitive high-performance liquid chromatography/mass spectrometric assay was used to measure the intact catechin metabolites, conjugates and free forms. Seven green tea catechins and their corresponding metabolites were identified postsupplementation in skin biopsies, 20 in blister fluid and 26 in plasma, with 15 green tea catechin metabolites present in both blister fluid and plasma. The valerolactone, O-methyl-M4-O-sulfate, a gut microbiota metabolite of catechins, was significantly increased 1.6-fold by UVR in blister fluid samples. In conclusion, there were some common catechin metabolites in the plasma and blister fluid, and the concentration was always higher in plasma. The results suggest that green tea catechins and metabolites are bioavailable in skin and provide a novel link between catechin metabolites derived from the skin and gut microbiota. PMID:26454512

  7. Atmospheric pressure plasma jet for bacterial decontamination and property improvement of fruit and vegetable processing wastewater

    NASA Astrophysics Data System (ADS)

    Mohamed, Abdel-Aleam H.; Shariff, Samir M. Al; Ouf, Salama A.; Benghanem, Mohamed

    2016-05-01

    An atmospheric pressure plasma jet was tested for decontaminating and improving the characteristics of wastewater derived from blackberry, date palm, tomato and beetroot processing industries. The jet was generated by blowing argon gas through a cylindrical alumina tube while a high voltage was applied between two electrodes surrounding the tube. Oxygen gas was mixed with argon at the rate of 0.2% and the argon mass flow was fixed at 4.5 slm. Images show that the generated plasma jet penetrated the treated wastewater samples. Plasma emission spectra show the presence of O and OH radicals as well as excited molecular nitrogen and argon. Complete decontamination of wastewater derived from date palm and tomato processing was achieved after 120 and 150 s exposure to the plasma jet, respectively. The bacterial count of wastewater from blackberry and beetroot was reduced by 0.41 and 2.24 log10 colony-forming units (CFU) per ml, respectively, after 180 s. Escherichia coli was the most susceptible bacterial species to the cold plasma while Shigella boydii had the minimum susceptibility, recording 1.30 and 3.34 log10 CFU ml-1, respectively, as compared to the 7.00 log10 initial count. The chemical oxygen demands of wastewater were improved by 57.5-93.3% after 180 s exposure to the plasma jet being tested. The endotoxins in the wastewater were reduced by up to 90.22%. The variation in plasma effectiveness is probably related to the antioxidant concentration of the different investigated wastewaters.

  8. An X-ray/SDSS sample. II. AGN-driven outflowing gas plasma properties

    NASA Astrophysics Data System (ADS)

    Perna, M.; Lanzuisi, G.; Brusa, M.; Cresci, G.; Mignoli, M.

    2017-10-01

    Aims: Galaxy-scale outflows are currently observed in many active galactic nuclei (AGNs); however, characterisation of them in terms of their (multi-) phase nature, amount of flowing material, and effects on their host galaxy is still unresolved. In particular, ionised gas mass outflow rate and related energetics are still affected by many sources of uncertainty. In this respect, outflowing gas plasma conditions, being largely unknown, play a crucial role. Methods: We have analysed stacked spectra and sub-samples of sources with high signal-to-noise temperature- and density-sensitive emission lines to derive the plasma properties of the outflowing ionised gas component. We did this by taking advantage of the spectroscopic analysis results we obtained while studying the X-ray/SDSS sample of 563 AGNs at z < 0.8 presented in our companion paper. For these sources, we also studied in detail various diagnostic diagrams to infer information about outflowing gas ionisation mechanisms. Results: We derive, for the first time, median values for electron temperature and density of outflowing gas from medium-size samples ( 30 targets) and stacked spectra of AGNs. Evidence of shock excitation are found for outflowing gas. Conclusions: We measure electron temperatures of the order of 1.7 × 104 K and densities of 1200 cm-3 for faint and moderately luminous AGNs (intrinsic X-ray luminosity 40.5 < log (LX) < 44 in the 2-10 keV band). We note that the electron density that is usually assumed (Ne = 100 cm-3) in ejected material might result in relevant overestimates of flow mass rates and energetics and, as a consequence, of the effects of AGN-driven outflows on the host galaxy.

  9. Relative and absolute reliability of measures of linoleic acid-derived oxylipins in human plasma.

    PubMed

    Gouveia-Figueira, Sandra; Bosson, Jenny A; Unosson, Jon; Behndig, Annelie F; Nording, Malin L; Fowler, Christopher J

    2015-09-01

    Modern analytical techniques allow for the measurement of oxylipins derived from linoleic acid in biological samples. Most validatory work has concerned extraction techniques, repeated analysis of aliquots from the same biological sample, and the influence of external factors such as diet and heparin treatment upon their levels, whereas less is known about the relative and absolute reliability of measurements undertaken on different days. A cohort of nineteen healthy males were used, where samples were taken at the same time of day on two occasions, at least 7 days apart. Relative reliability was assessed using Lin's concordance correlation coefficients (CCC) and intraclass correlation coefficients (ICC). Absolute reliability was assessed by Bland-Altman analyses. Nine linoleic acid oxylipins were investigated. ICC and CCC values ranged from acceptable (0.56 [13-HODE]) to poor (near zero [9(10)- and 12(13)-EpOME]). Bland-Altman limits of agreement were in general quite wide, ranging from ±0.5 (12,13-DiHOME) to ±2 (9(10)-EpOME; log10 scale). It is concluded that relative reliability of linoleic acid-derived oxylipins varies between lipids with compounds such as the HODEs showing better relative reliability than compounds such as the EpOMEs. These differences should be kept in mind when designing and interpreting experiments correlating plasma levels of these lipids with factors such as age, body mass index, rating scales etc. Copyright © 2015 Elsevier Inc. All rights reserved.

  10. Enfuvirtide Cerebrospinal Fluid (CSF) Pharmacokinetics and Potential Use in Defining CSF HIV-1 Origin

    PubMed Central

    Price, Richard W; Parham, Robin; Lu, Jing; Wring, Stephen A.; Baker, Brian; Sailstad, Jeff; Hoh, Rebecca; Liegler, Teri; Spudich, Serena; Kuritzkes, Daniel R; Deeks, Steven G

    2009-01-01

    Background Enfuvirtide is a potent inhibitor of systemic HIV-1 replication, but its penetration into the human central nervous system (CNS) has not been analyzed. Here, we define cerebrospinal fluid (CSF) enfuvirtide pharmacokinetics and present a case illustrating the use of enfuvirtide as a probe to trace the origins of CSF HIV-1 quasispecies. Methods Enfuvirtide CSF PK was assessed in 18 CSF and plasma sample pairs from 4 HIV-1-infected subjects. Enfuvirtide levels were measured by liquid chromatography tandem mass spectrometry using known standards and controls that including spiked CSF samples from untreated, HIV-negative subjects. A segment of the gp41-coding region encompassing the heptad repeat (HR)-1 and HR-2 domains was amplified from selected CSF and plasma samples, and independent clones sequenced to assess resistance-associated mutations. Results CSF and plasma samples obtained between 2 and 20 hrs after enfuvirtide injection showed plasma concentrations similar to previous reports (mean 3.687 +/−1.828 µg/ml SD) with prolonged decay. By contrast, enfuvirtide in all CSF samples was below the assay detection limit of 0.025 µg/ml. In one subject, who developed a transient increase in CSF HIV-1 RNA, 7 of 7 CSF and plasma clones had identical enfuvirtide resistance-associated V38A mutation, suggesting that the CSF quasispecies derived from that of blood. Conclusions Enfuvirtide CSF penetration into CSF is negligible, and thus in clinical settings where direct CNS drug exposure is critical, this drug will likely not directly contribute to the local therapeutic effect. Enfuvirtide can be used as a tool to dissect the origin of the CNS virus. PMID:18572749

  11. Acylcarnitine Profiles in Plasma and Tissues of Hyperglycemic NZO Mice Correlate with Metabolite Changes of Human Diabetes

    PubMed Central

    Daniel, Hannelore

    2018-01-01

    The New Zealand obese (NZO) mouse is a polygenic model for obesity and diabetes with obese females and obese, diabetes-prone males, used to study traits of the metabolic syndrome like type 2 diabetes mellitus (T2DM), obesity, and dyslipidaemia. By using LC-MS/MS, we here examine the suitability of this model to mirror tissue-specific changes in acylcarnitine (AC) and amino acid (AA) species preceding T2DM which may reflect patterns investigated in human metabolism. We observed high concentrations of fatty acid-derived ACs in 11 female mice, high abundance of branched-chain amino acid- (BCAA-) derived ACs in 6 male mice, and slight increases in BCAA-derived ACs in the remaining 6 males. Principal component analysis (PCA) including all ACs and AAs confirmed our hypothesis especially in plasma samples by clustering females, males with high BCAA-derived ACs, and males with slight increases in BCAA-derived ACs. Concentrations of insulin, blood glucose, NEFAs, and triacylglycerols (TAGs) further supported the hypothesis of high BCAA-derived ACs being able to mirror the onset of diabetic traits in male individuals. In conclusion, alterations in AC and AA profiles overlap with observations from human studies indicating the suitability of NZO mice to study metabolic changes preceding human T2DM. PMID:29854816

  12. Traumatic Hemothorax Blood Contains Elevated Levels of Microparticles that are Prothrombotic but Inhibit Platelet Aggregation.

    PubMed

    Mitchell, Thomas A; Herzig, Maryanne C; Fedyk, Chriselda G; Salhanick, Marc A; Henderson, Aaron T; Parida, Bijaya K; Prat, Nicolas J; Dent, Daniel L; Schwacha, Martin G; Cap, Andrew P

    2017-06-01

    Autotransfusion of shed blood from traumatic hemothorax is an attractive option for resuscitation of trauma patients in austere environments. However, previous analyses revealed that shed hemothorax (HX) blood is defibrinated, thrombocytopenic, and contains elevated levels of D-dimer. Mixing studies with normal pooled plasma demonstrated hypercoagulability, evoking concern for potentiation of acute traumatic coagulopathy. We hypothesized that induction of coagulopathic changes by shed HX blood may be due to increases in cellular microparticles (MP) and that these may also affect recipient platelet function. Shed HX blood was obtained from 17 adult trauma patients under an Institutional Review Board approved prospective observational protocol. Blood samples were collected every hour up to 4 h after thoracostomy tube placement. The corresponding plasma was isolated and frozen for analysis. The effects of shed HX frozen plasma (HFP) and isolated HX microparticles (HMP) on coagulation and platelet function were assessed through mixing studies with platelet-rich plasma at various dilutions followed by analysis with thromboelastometry (ROTEM), platelet aggregometry (Multiplate), enzyme-linked immunosorbent assays, and flow cytometry. Furthermore, HFP was assessed for von Willebrand factor antigen levels and multimer content, and plasma-free hemoglobin. ROTEM analysis demonstrated that diluted HFP and isolated HMP samples decreased clotting time, clotting formation time, and increased α angle, irrespective of sample concentrations, when compared with diluted control plasma. Isolated HMP inhibited platelet aggregation in response to adenosine diphosphate, arachidonic acid, and collagen. HFP contained elevated levels of fibrin-degradation products and tissue factor compared with control fresh frozen plasma samples. MP concentrations in HFP were significantly increased and enriched in events positive for phosphatidylserine, tissue factor, CD235, CD45, CD41a, and CD14. von Willebrand factor (vWF) multimer analysis revealed significant loss of high molecular weight multimers in HFP samples. Plasma-free hemoglobin levels were 8-fold higher in HFP compared with fresh frozen plasma. HFP induces plasma hypercoagulability that is likely related to increased tissue factor and phosphatidylserine expression originating from cell-derived MP. In contrast, platelet dysfunction is induced by HMP, potentially aggravated by depletion of high molecular weight multimers of vWF. Thus, autologous transfusion of shed traumatic hemothorax blood may induce a range of undesirable effects in patients with acute traumatic coagulopathy.

  13. The effective concentration of epsilon-aminocaproic Acid for inhibition of fibrinolysis in neonatal plasma in vitro.

    PubMed

    Yurka, Heather G; Wissler, Richard N; Zanghi, Christine N; Liu, Xiang; Tu, Xin; Eaton, Michael P

    2010-07-01

    Pediatric patients, particularly neonates, are at high risk for bleeding complications after cardiovascular surgery because of their immature hemostatic system, small size, and the complex operations they require. Activation of intravascular fibrinolysis is one of the principle effects of cardiopulmonary bypass that causes poor postoperative hemostasis. This complication has long been recognized and treated with antifibrinolytic medications, including the lysine analog epsilon aminocaproic acid (EACA). The therapeutic plasma concentration of EACA has been scientifically determined for the adult population, but the current recommended dosage for neonates has been empirically derived from adult studies. Therefore, we investigated the appropriate concentration of EACA for neonates undergoing bypass. We conducted an in vitro study using neonatal plasma derived from the placenta/cord units from 20 term, elective cesarean deliveries. Graded concentrations of EACA were added to aliquots of the plasma pool before activating fibrinolysis with tissue-type plasminogen activator. Standard kaolin-activated thromboelastograms were then run with the primary outcome variable being estimated percent lysis. These procedures were repeated on samples of commercially available pooled adult normal plasma for comparison. We found that neonatal plasma required significantly lower concentrations of EACA to completely prevent fibrinolysis than did adult plasma (44.2 microg/mL and 47.8 microg/mL for neonatal plasma and 94.4 and 131.4 microg/mL in adult plasma for 400 and 1000 U/mL of plasminogen activator, respectively, P < 0.001). Our data establish the minimal effective concentration of EACA necessary to completely prevent fibrinolysis in neonatal blood in vitro. This concentration is significantly less than that targeted by current dosing schemes, indicating that neonates are possibly being exposed to greater levels of EACA than is clinically necessary.

  14. Sustainability of a public system for plasma collection, contract fractionation and plasma-derived medicinal product manufacturing

    PubMed Central

    Grazzini, Giuliano; Ceccarelli, Anna; Calteri, Deanna; Catalano, Liviana; Calizzani, Gabriele; Cicchetti, Americo

    2013-01-01

    Background In Italy, the financial reimbursement for labile blood components exchanged between Regions is regulated by national tariffs defined in 1991 and updated in 1993–2003. Over the last five years, the need for establishing standard costs of healthcare services has arisen critically. In this perspective, the present study is aimed at defining both the costs of production of blood components and the related prices, as well as the prices of plasma-derived medicinal products obtained by national plasma, to be used for interregional financial reimbursement. Materials and methods In order to analyse the costs of production of blood components, 12 out 318 blood establishments were selected in 8 Italian Regions. For each step of the production process, driving costs were identified and production costs were. To define the costs of plasma-derived medicinal products obtained by national plasma, industrial costs currently sustained by National Health Service for contract fractionation were taken into account. Results The production costs of plasma-derived medicinal products obtained from national plasma showed a huge variability among blood establishments, which was much lower after standardization. The new suggested plasma tariffs were quite similar to those currently in force. Comparing the overall costs theoretically sustained by the National Health Service for plasma-derived medicinal products obtained from national plasma to current commercial costs, demonstrates that the national blood system could gain a 10% cost saving if it were able to produce plasma for fractionation within the standard costs defined in this study. Discussion Achieving national self-sufficiency through the production of plasma-derived medicinal products from national plasma, is a strategic goal of the National Health Service which must comply not only with quality, safety and availability requirements but also with the increasingly pressing need for economic sustainability. PMID:24333307

  15. Sustainability of a public system for plasma collection, contract fractionation and plasma-derived medicinal product manufacturing.

    PubMed

    Grazzini, Giuliano; Ceccarelli, Anna; Calteri, Deanna; Catalano, Liviana; Calizzani, Gabriele; Cicchetti, Americo

    2013-09-01

    In Italy, the financial reimbursement for labile blood components exchanged between Regions is regulated by national tariffs defined in 1991 and updated in 1993-2003. Over the last five years, the need for establishing standard costs of healthcare services has arisen critically. In this perspective, the present study is aimed at defining both the costs of production of blood components and the related prices, as well as the prices of plasma-derived medicinal products obtained by national plasma, to be used for interregional financial reimbursement. In order to analyse the costs of production of blood components, 12 out 318 blood establishments were selected in 8 Italian Regions. For each step of the production process, driving costs were identified and production costs were. To define the costs of plasma-derived medicinal products obtained by national plasma, industrial costs currently sustained by National Health Service for contract fractionation were taken into account. The production costs of plasma-derived medicinal products obtained from national plasma showed a huge variability among blood establishments, which was much lower after standardization. The new suggested plasma tariffs were quite similar to those currently in force. Comparing the overall costs theoretically sustained by the National Health Service for plasma-derived medicinal products obtained from national plasma to current commercial costs, demonstrates that the national blood system could gain a 10% cost saving if it were able to produce plasma for fractionation within the standard costs defined in this study. Achieving national self-sufficiency through the production of plasma-derived medicinal products from national plasma, is a strategic goal of the National Health Service which must comply not only with quality, safety and availability requirements but also with the increasingly pressing need for economic sustainability.

  16. Multiplex picoliter-droplet digital PCR for quantitative assessment of EGFR mutations in circulating cell-free DNA derived from advanced non-small cell lung cancer patients.

    PubMed

    Yu, Qian; Huang, Fei; Zhang, Meilin; Ji, Haiying; Wu, Shenchao; Zhao, Ying; Zhang, Chunyan; Wu, Jiong; Wang, Beili; Pan, Baisheng; Zhang, Xin; Guo, Wei

    2017-08-01

    To explore the possible diagnostic value of liquid biopsy, two multiplex panels using picoliter-droplet digital polymerase chain reaction (ddPCR) were established to quantitatively assess the epidermal growth factor receptor (EGFR) mutations in cell‑free DNA (cfDNA) extracted from the plasma of advanced non‑small cell lung cancer (NSCLC) patients. Plasma samples derived from 22 patients with stage IIIB/IV NSCLC harboring EGFR mutations in matched tumor tissues confirmed by amplification refractory mutation system (ARMS) analysis were subjected to two multiplex ddPCR panels to assess the abundance of tyrosine kinase inhibitor (TKI) ‑sensitive (19DEL, L858R) and TKI‑resistant (T790 M) mutations. Fluctuations in EGFR mutant abundance were monitored by either of the multiplex ddPCR panels for three patients undergoing EGFR‑TKI treatment, with serial plasma sample collections over 2 months. The multiplex ddPCR panels applied to plasma cfDNA from advanced NSCLC patients achieved a total concordance rate of 80% with the EGFR mutation profiles obtained by ARMS from matched biopsy tumor specimens (90% for 19DEL, 95% for L858R, 95% for T790M, respectively) and revealed additional mutant alleles in two subjects. The respective sensitivity and specificity were 90.9 and 88.9% for 19DEL, 87.5 and 100% for L858R, 100 and 93.8% for T790M. The fluctuations of EGFR mutant abundance in serial plasma cfDNA were in accordance with the changes in tumor size as assessed by imaging scans. The authors demonstrated the utility of multiplex ddPCR panels with ultra‑sensitivity for quantitative analysis of EGFR mutations in plasma cfDNA and obtained promising usefulness in EGFR‑TKI decision‑making for advanced NSCLC patients.

  17. Multiplex picoliter-droplet digital PCR for quantitative assessment of EGFR mutations in circulating cell-free DNA derived from advanced non-small cell lung cancer patients

    PubMed Central

    Yu, Qian; Huang, Fei; Zhang, Meilin; Ji, Haiying; Wu, Shenchao; Zhao, Ying; Zhang, Chunyan; Wu, Jiong; Wang, Beili; Pan, Baisheng; Zhang, Xin; Guo, Wei

    2017-01-01

    To explore the possible diagnostic value of liquid biopsy, two multiplex panels using picoliter-droplet digital polymerase chain reaction (ddPCR) were established to quantitatively assess the epidermal growth factor receptor (EGFR) mutations in cell-free DNA (cfDNA) extracted from the plasma of advanced non-small cell lung cancer (NSCLC) patients. Plasma samples derived from 22 patients with stage IIIB/IV NSCLC harboring EGFR mutations in matched tumor tissues confirmed by amplification refractory mutation system (ARMS) analysis were subjected to two multiplex ddPCR panels to assess the abundance of tyrosine kinase inhibitor (TKI) -sensitive (19DEL, L858R) and TKI-resistant (T790 M) mutations. Fluctuations in EGFR mutant abundance were monitored by either of the multiplex ddPCR panels for three patients undergoing EGFR-TKI treatment, with serial plasma sample collections over 2 months. The multiplex ddPCR panels applied to plasma cfDNA from advanced NSCLC patients achieved a total concordance rate of 80% with the EGFR mutation profiles obtained by ARMS from matched biopsy tumor specimens (90% for 19DEL, 95% for L858R, 95% for T790M, respectively) and revealed additional mutant alleles in two subjects. The respective sensitivity and specificity were 90.9 and 88.9% for 19DEL, 87.5 and 100% for L858R, 100 and 93.8% for T790M. The fluctuations of EGFR mutant abundance in serial plasma cfDNA were in accordance with the changes in tumor size as assessed by imaging scans. The authors demonstrated the utility of multiplex ddPCR panels with ultra-sensitivity for quantitative analysis of EGFR mutations in plasma cfDNA and obtained promising usefulness in EGFR-TKI decision-making for advanced NSCLC patients. PMID:29067441

  18. Lipidomic and proteomic analysis of exosomes from mouse cortical collecting duct cells.

    PubMed

    Dang, Viet D; Jella, Kishore Kumar; Ragheb, Ragy R T; Denslow, Nancy D; Alli, Abdel A

    2017-12-01

    Exosomes are endosome-derived nanovesicles that are involved in cellular communication and signaling. Exosomes are produced by epithelial cells and are found in biologic fluids including blood and urine. The packaged material within exosomes includes proteins and lipids, but the molecular comparison within exosome subtypes is largely unknown. The purpose of this study was to investigate differences between exosomes derived from the apical plasma membrane and basolateral plasma membrane of polarized murine cortical collecting duct principal cells. Nanoparticle tracking analysis showed that the size and concentration of apical and basolateral exosomes remained relatively stable across 3 different temperatures (23, 37, and 42°C). Liquid chromatography-tandem mass spectrometry analysis revealed marked differences between the proteins packaged within the two types of exosomes from the same cells. Several proteins expressed at the inner leaflet of the plasma membrane, including α-actinin-1, moesin, 14-3-3 protein ζ/δ, annexin A1/A3/A4/A5/A6, clathrin heavy chain 1, glyceraldehyde-3-phosphate dehydrogenase, α-enolase, filamin-A, and heat shock protein 90, were identified in samples of apical plasma membrane-derived exosomes, but not in basolateral plasma membrane exosomes from mouse cortical collecting duct cells. In addition to differences at the protein level, mass spectrometry-based shotgun lipidomics analysis showed significant differences in the lipid classes and fatty acid composition of the two types of exosomes. We found higher levels of sphingomyelin and lower levels of cardiolipin, among other phospholipids in the apical plasma membrane compared to the basolateral plasma membrane exosomes. The molecular analyses of exosome subtypes presented herein will contribute to our understanding of exosome biogenesis, and the results may have potential implications for biomarker discovery.-Dang, V. D., Jella, K. K., Ragheb, R. R. T., Denslow, N. D., Alli, A. A. Lipidomic and proteomic analysis of exosomes from mouse cortical collecting duct cells. © FASEB.

  19. Paper-Based MicroRNA Expression Profiling from Plasma and Circulating Tumor Cells.

    PubMed

    Leong, Sai Mun; Tan, Karen Mei-Ling; Chua, Hui Wen; Huang, Mo-Chao; Cheong, Wai Chye; Li, Mo-Huang; Tucker, Steven; Koay, Evelyn Siew-Chuan

    2017-03-01

    Molecular characterization of circulating tumor cells (CTCs) holds great promise for monitoring metastatic progression and characterizing metastatic disease. However, leukocyte and red blood cell contamination of routinely isolated CTCs makes CTC-specific molecular characterization extremely challenging. Here we report the use of a paper-based medium for efficient extraction of microRNAs (miRNAs) from limited amounts of biological samples such as rare CTCs harvested from cancer patient blood. Specifically, we devised a workflow involving the use of Flinders Technology Associates (FTA) ® Elute Card with a digital PCR-inspired "partitioning" method to extract and purify miRNAs from plasma and CTCs. We demonstrated the sensitivity of this method to detect miRNA expression from as few as 3 cancer cells spiked into human blood. Using this method, background miRNA expression was excluded from contaminating blood cells, and CTC-specific miRNA expression profiles were derived from breast and colorectal cancer patients. Plasma separated out during purification of CTCs could likewise be processed using the same paper-based method for miRNA detection, thereby maximizing the amount of patient-specific information that can be derived from a single blood draw. Overall, this paper-based extraction method enables an efficient, cost-effective workflow for maximized recovery of small RNAs from limited biological samples for downstream molecular analyses. © 2016 American Association for Clinical Chemistry.

  20. A multicolor flow cytometric assay for measurement of platelet-derived microparticles.

    PubMed

    Mobarrez, Fariborz; Antovic, Jovan; Egberg, Nils; Hansson, Mona; Jörneskog, Gun; Hultenby, Kjell; Wallén, Håkan

    2010-03-01

    Flow cytometry (FCM) is the most commonly used method for detection of platelet-derived microparticles (PDMPs), but it is poorly standardized and mainly used for "bedside" analyses in fresh samples. If PDMPs could be analyzed in previously frozen samples it would increase the usefulness of the method. However, cell membrane fragments from contaminating cells created during freezing/thawing may cause artifacts and disturb measurements. PDMPs were labeled with monoclonal antibodies directed against CD42a and CD62P, or CD42a and CD142. The PDMP gate was determined using forward scatter (FSC) and CD42a expression. The mean fluorescence intensities (MFIs) of CD62P or CD142 positive particles were translated into MESF -values (Molecules of Equivalent Soluble Fluorochrome) using a standard curve. FITC-labeled phalloidin (which binds to intracellular actin) was used to detect destroyed cells/cell fragments. Phalloidin-positive particles were significantly more common in supernatants of frozen/thawed platelet rich and platelet poor plasma samples compared with supernatants of platelet free plasma. High-speed centrifugation was then used to obtain PDMP samples with low contamination of cell fragments. Electron microscopy showed that these samples contained numerous round stained particles with cellular membranes of a size of 100-700 nm. Reproducibility experiments using plasma samples from healthy individuals showed that the coefficients of variation (CVs) of MESF values of CD62P and CD142 (both intra- and interassay) were <10%, and the variation between two cytometers in two different laboratories was <5%. We also found that PDMP expression of CD142 (i.e. tissue factor [TF]) and CD62P (i.e P-selectin) was around two times higher in samples from type 1-diabetes patients compared with those from healthy controls (p<0.001). The use of MESF values to quantify PDMP expression of P-selectin and TF yields reproducible data and enables comparison of data between laboratories. If high-speed centrifugation is performed, contamination of cell fragments is low in frozen/thawed samples. (c) 2009 Elsevier Ltd. All rights reserved.

  1. Total sulfur determination in gasoline, kerosene and diesel fuel using inductively coupled plasma optical emission spectrometry after direct sample introduction as detergent emulsions

    NASA Astrophysics Data System (ADS)

    Santelli, Ricardo Erthal; Oliveira, Eliane Padua; de Carvalho, Maria de Fátima Batista; Bezerra, Marcos Almeida; Freire, Aline Soares

    2008-07-01

    Herein, we present the development of a procedure for the determination of total sulfur in petroleum-derived products (gasoline, kerosene and diesel fuel) employing inductively coupled plasma optical emission spectrometry (ICP OES). For this procedure, samples were prepared as emulsions that were made using concentrated nitric acid, Triton X-100, sample, and ultra pure water in proportions of 5/10/7/78% (v/v), respectively. Sample volumes were weighed because of the density differences, and oxygen was added to the sheat gas entrance of the ICP OES in order to decrease carbon deposition in the torch and to minimize background effects. A Doehlert design was applied as an experimental matrix to investigate the flow ratios of argon (sheat and plasma gas) and oxygen in relation to the signal-to-background ratio. A comparative study among the slopes of the analytical curves built in aqueous media, surfactant/HNO 3, and by spike addition for several sample emulsions indicates that a unique solution of surfactant in acidic media can be employed to perform the external calibration for analysis of the emulsions. The developed procedure allows for the determination of the total sulfur content in petroleum derivatives with a limit of detection (LOD) and limit of quantification (LOQ) of 0.72 and 2.4 μg g - 1 , respectively. Precision values, expressed as the relative standard deviations (% RSD, n = 10) for 12 and 400 μg g - 1 , were 2.2% and 1.3%, respectively. The proposed procedure was applied toward the determination of total sulfur in samples of gasoline, kerosene, and diesel fuel commercialized in the city of Niterói/RJ, Brazil. The accuracy of the proposed method was evaluated by the determination of the total sulfur in three different standard reference materials (SRM): NIST 2723a (sulfur in diesel fuel oil), NIST 1616b (sulfur in kerosene), and NIST 2298 (sulfur in gasoline). The data indicate that the methodology can be successfully applied to these types of samples. Spiking tests, conducted with the analyzed samples, indicate that recoveries are between 97 and 103%.

  2. Increased volume of distribution for recombinant activated factor VII and longer plasma-derived factor VII half-life may explain their long lasting prophylactic effect.

    PubMed

    Mathijssen, Natascha C J; Masereeuw, Rosalinde; Holme, Pal Andre; van Kraaij, Marian G J; Laros-van Gorkom, Britta A P; Peyvandi, Flora; van Heerde, Waander L

    2013-08-01

    Prophylaxis with plasma-derived or recombinant activated factor VII is beneficial in severe factor VII deficiency. To understand why prophylactic treatment with both products is efficacious, we conducted a pharmacokinetic study. Ten factor VII deficient patients were treated with either recombinant activated (20 μg/kg) or plasma-derived (25 IU/kg) factor VII in a cross-over design. Pharmacokinetic parameters were analyzed through activated factor VII activity, factor VII clotting activity, and factor VII antigen levels on depicted time points. Factor VII activity half-lifes, determined by non-compartmental and one-compartmental analysis (results in brackets), were shorter for recombinant activated (1.4h; 0.7h) than for plasma-derived factor VII (6.8h; 3.2h); both recombinant activated (5.1h; 2.1h and plasma-derived factor VII (5.8h; 3.2h) resulted in longer half-lives of factor VII antigen. Activated factor VII half-lives (based on activated factor VII activity levels) were significantly higher compared to factor VII clotting activity (1.6h; 0.9h). Volumes of distribution were significantly higher for activated factor VII (236 ml/kg; 175 ml/kg, measured by activated factor VII) as compared to plasma-derived factor VII (206 ml/kg; 64 ml/kg, measured by factor FVII activity), suggesting a plasma- and extracellular fluid distribution for recombinant activated factor VII. Recombinant activated factor VII showed significantly shorter half-lifes than plasma-derived factor VII. Volumes of distribution were significantly higher for treatment with recombinant activated factor VII. The longer half-life for plasma-derived factor VII, compared to recombinant activated factor VII, and the increased volume of distribution for recombinant activated factor VII, compared to plasma-derived factor VII may further elucidate the beneficial effect of prophylactic treatment of both products. Copyright © 2013 Elsevier Ltd. All rights reserved.

  3. 75 FR 55803 - Transmissible Spongiform Encephalopathies Advisory Committee; Notice of Meeting

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-09-14

    ... Creutzfeldt-Jakob disease (vCJD) agent in U.S.-licensed plasma-derived Factor VIII and (2) labeling of blood and blood components and plasma-derived products, including plasma-derived albumin and products..., the Committee will hear informational presentations related to FDA's geographic donor deferral policy...

  4. Electromagnetic fluctuations in magnetized plasmas. I. The rigorous relativistic kinetic theory

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schlickeiser, R., E-mail: rsch@tp4.rub.de, E-mail: yoonp@umd.edu; Yoon, P. H., E-mail: rsch@tp4.rub.de, E-mail: yoonp@umd.edu; School of Space Research, Kyung Hee University, Yongin-Si, Gyeonggi-Do 446-701

    2015-07-15

    Using the system of the Klimontovich and Maxwell equations, the general linear fluctuation theory for magnetized plasmas is developed. General expressions for the electromagnetic fluctuation spectra (electric and magnetic fields) from uncorrelated plasma particles in plasmas with a uniform magnetic field are derived, which are covariantly correct within the theory of special relativity. The general fluctuation spectra hold for plasmas of arbitrary composition, arbitrary momentum dependences of the plasma particle distribution functions, and arbitrary orientations of the wave vector with respect to the uniform magnetic field. Moreover, no restrictions on the values of the real and the imaginary parts ofmore » the frequency are made. The derived fluctuation spectra apply to both non-collective fluctuations and collective plasma eigenmodes in magnetized plasmas. In the latter case, kinetic equations for the components of fluctuating electric and magnetic fields in magnetized plasmas are derived that include the effect of spontaneous emission and absorption. In the limiting case of an unmagnetized plasmas, the general fluctuation spectra correctly reduce to the unmagnetized fluctuation spectra derived before.« less

  5. A simple, rapid and stability indicating validated method for quantification of lamotrigine in human plasma and dry plasma spot using LC-ESI-MS/MS: Application in clinical study.

    PubMed

    Namdev, Kuldeep Kumar; Dwivedi, Jaya; Chilkoti, Deepak Chandra; Sharma, Swapnil

    2018-01-01

    Lamotrigine (LTZ) is a phenyltriazine derivative which belongs to anti-epileptic drugs (AEDs) class and prescribed as mono- or adjunctive-therapy in treatment of epilepsy. Therapeutic drug monitoring (TDM) of AEDs provides a valid clinical tool in optimization of overall therapy. However, TDM is challenging due to the high biological samples (plasma/blood) storage/shipment costs and the limited availability of laboratories providing TDM services. Sampling in the form of dry plasma spot (DPS) or dry blood spot (DBS) are suitable alternative to overcome these issues. We developed and validated a new method for quantification of LTZ in human plasma and DPS. The extraction of LTZ from plasma and DPS was performed using liquid-liquid extraction with diethyl ether and an extraction solution composed of diethyl ether- methyl tert-butyl ether- acetone (50:30:20, v/v/v), respectively. Lamotrigine- 13C3, d3 was used as internal standard (ISTD) and the chromatographic separation was achieved on Hypurity Advance C18 column (150×4.6mm, 5μm). Quantitative estimation of LTZ and ISTD was performed on a liquid chromatography tandem mass spectrometer coupled with electrospray ionization interface operated under positive mode of ionization. Calibration curves were linear (r 2 >0.99) over the concentration range of 10-3020ng/mL for both plasma and DPS. Statistical analysis provides insignificant difference between LTZ concentration extracted from plasma and DPS samples. The method is found suitable for application in clinical study and in therapeutic monitoring of LTZ. To the best of our knowledge this is the first report which describing a validated stability indicating assay for quantification of LTZ in dry plasma spot. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. Plasma and Urinary Phenolic Profiles after Acute and Repetitive Intake of Wild Blueberry.

    PubMed

    Feliciano, Rodrigo P; Istas, Geoffrey; Heiss, Christian; Rodriguez-Mateos, Ana

    2016-08-25

    Recent studies have shown that blueberries may have cardiovascular and cognitive health benefits. In this work, we investigated the profile of plasma and urine (poly)phenol metabolites after acute and daily consumption of wild blueberries for 30 days in 18 healthy men. The inter-individual variability in plasma and urinary polyphenol levels was also investigated. Blood samples were collected at baseline and 2 h post-consumption on day 1 and day 30. Twenty-four-hour urine was also collected on both days. A total of 61 phenolic metabolites were quantified in plasma at baseline, of which 43 increased after acute or chronic consumption of blueberries over one month. Benzoic and catechol derivatives represented more than 80% of the changes in phenolic profile after 2 h consumption on day 1, whereas hippuric and benzoic derivatives were the major compounds that increased at 0 and 2 h on day 30, respectively. The total (poly)phenol urinary excretion remained unchanged after 30 days of wild blueberry intake. The inter-individual variability ranged between 40%-48% in plasma and 47%-54% in urine. Taken together, our results illustrate that blueberry (poly)phenols are absorbed and extensively metabolized by phase II enzymes and by the gut microbiota, leading to a whole array of metabolites that may be responsible for the beneficial effects observed after blueberry consumption.

  7. Growth factor and pro-inflammatory cytokine contents in platelet-rich plasma (PRP), plasma rich in growth factors (PRGF), advanced platelet-rich fibrin (A-PRF), and concentrated growth factors (CGF).

    PubMed

    Masuki, Hideo; Okudera, Toshimitsu; Watanebe, Taisuke; Suzuki, Masashi; Nishiyama, Kazuhiko; Okudera, Hajime; Nakata, Koh; Uematsu, Kohya; Su, Chen-Yao; Kawase, Tomoyuki

    2016-12-01

    The development of platelet-rich fibrin (PRF) drastically simplified the preparation procedure of platelet-concentrated biomaterials, such as platelet-rich plasma (PRP), and facilitated their clinical application. PRF's clinical effectiveness has often been demonstrated in pre-clinical and clinical studies; however, it is still controversial whether growth factors are significantly concentrated in PRF preparations to facilitate wound healing and tissue regeneration. To address this matter, we performed a comparative study of growth factor contents in PRP and its derivatives, such as advanced PRF (A-PRF) and concentrated growth factors (CGF). PRP and its derivatives were prepared from the same peripheral blood samples collected from healthy donors. A-PRF and CGF preparations were homogenized and centrifuged to produce extracts. Platelet and white blood cell counts in A-PRF and CGF preparations were determined by subtracting those counts in red blood cell fractions, supernatant acellular serum fractions, and A-PRF/CGF exudate fractions from those counts of whole blood samples. Concentrations of growth factors (TGF-β1, PDGF-BB, VEGF) and pro-inflammatory cytokines (IL-1β, IL-6) were determined using ELISA kits. Compared to PRP preparations, both A-PRF and CGF extracts contained compatible or higher levels of platelets and platelet-derived growth factors. In a cell proliferation assay, both A-PRF and CGF extracts significantly stimulated the proliferation of human periosteal cells without significant reduction at higher doses. These data clearly demonstrate that both A-PRF and CGF preparations contain significant amounts of growth factors capable of stimulating periosteal cell proliferation, suggesting that A-PRF and CGF preparations function not only as a scaffolding material but also as a reservoir to deliver certain growth factors at the site of application.

  8. Pharmacokinetics, excretion of 8-cetylberberine and its main metabolites in rat urine.

    PubMed

    Hu, Yuli; Fan, Shoujun; Liao, Xiaobing; Chen, Chao; Su, Liang; Li, Xuegang

    2017-01-05

    Berberine (BBR) is a bioactive plant ingredient derived from the roots and bark of Berberis aristata and Coptis chinensis and has a wide variety of pharmacological effects. 8-cetylberberine (8-BBR-C16) is the berberine (BBR) derivative reconstructed from adding octadecyl at C-8 of BBR to enhance its activity. This study presents a reliable method for the determination of BBR and 8-BBR-C16 in rat plasma, urine and feces. BBR and 8-BBR-C16 were determined by HPLC-UV after liquid-liquid extraction for plasma samples, and solid-phase extraction for urinary and fecal samples. The method was linear over the concentration range of 10-300 ng·ml -1 for the plasma samples, 25-2000 ng·ml -1 for the urinary samples, and 100-2000 ng·g -1 for the fecal samples. Furthermore, a metabolic investigation on urine was performed by LC/MS/MS analysis to identify the structures of 8-BBR-C16 metabolites by full scan and product ion scan. Adult Sprague-Dawley rats were divided into two groups. In the control group, rats received 80 mg·kg -1 BBR, and in the drug-treated group, rats received 80 mg·kg -1 8-BBR-C16. The results indicate that there were significant differences in the pharmacokinetic parameters and in the accumulated excretion levels between the control group and the drug-treated group. The C max and AUC 0-t of 8-BBR-C16 were 2.8 and 12.9 times higher than those of BBR, and the relative bioavailability of BBR to 8-BBR-C16 was 7.7%. The total excretion amount through the urine and feces of 8-BBR-C16 was 76.9%, but that of BBR was only 20.5%. Additionally, 8-BBR-C16 was metabolized in rat urine with phase I demethylation and phase II glucuronidation or sulfation. Copyright © 2016 Elsevier B.V. All rights reserved.

  9. Absorption spectroscopy setup for determination of whole human blood and blood-derived materials spectral characteristics

    NASA Astrophysics Data System (ADS)

    Wróbel, M. S.; Gnyba, M.; Milewska, D.; Mitura, K.; Karpienko, K.

    2015-09-01

    A dedicated absorption spectroscopy system was set up using tungsten-halogen broadband source, optical fibers, sample holder, and a commercial spectrometer with CCD array. Analysis of noise present in the setup was carried out. Data processing was applied to the absorption spectra to reduce spectral noise, and improve the quality of the spectra and to remove the baseline level. The absorption spectra were measured for whole blood samples, separated components: plasma, saline, washed erythrocytes in saline and human whole blood with biomarkers - biocompatible nanodiamonds (ND). Blood samples had been derived from a number of healthy donors. The results prove a correct setup arrangement, with adequate preprocessing of the data. The results of blood-ND mixtures measurements show no toxic effect on blood cells, which proves the NDs as a potential biocompatible biomarkers.

  10. A practical guide for the identification of membrane and plasma membrane proteins in human embryonic stem cells and human embryonal carcinoma cells.

    PubMed

    Dormeyer, Wilma; van Hoof, Dennis; Mummery, Christine L; Krijgsveld, Jeroen; Heck, Albert J R

    2008-10-01

    The identification of (plasma) membrane proteins in cells can provide valuable insights into the regulation of their biological processes. Pluripotent cells such as human embryonic stem cells and embryonal carcinoma cells are capable of unlimited self-renewal and share many of the biological mechanisms that regulate proliferation and differentiation. The comparison of their membrane proteomes will help unravel the biological principles of pluripotency, and the identification of biomarker proteins in their plasma membranes is considered a crucial step to fully exploit pluripotent cells for therapeutic purposes. For these tasks, membrane proteomics is the method of choice, but as indicated by the scarce identification of membrane and plasma membrane proteins in global proteomic surveys it is not an easy task. In this minireview, we first describe the general challenges of membrane proteomics. We then review current sample preparation steps and discuss protocols that we found particularly beneficial for the identification of large numbers of (plasma) membrane proteins in human tumour- and embryo-derived stem cells. Our optimized assembled protocol led to the identification of a large number of membrane proteins. However, as the composition of cells and membranes is highly variable we still recommend adapting the sample preparation protocol for each individual system.

  11. Alternative methods for CYP2D6 phenotyping: comparison of dextromethorphan metabolic ratios from AUC, single point plasma, and urine.

    PubMed

    Chen, Rui; Wang, Haotian; Shi, Jun; Hu, Pei

    2016-05-01

    CYP2D6 is a high polymorphic enzyme. Determining its phenotype before CYP2D6 substrate treatment can avoid dose-dependent adverse events or therapeutic failures. Alternative phenotyping methods of CYP2D6 were compared to aluate the appropriate and precise time points for phenotyping after single-dose and ultiple-dose of 30-mg controlled-release (CR) dextromethorphan (DM) and to explore the antimodes for potential sampling methods. This was an open-label, single and multiple-dose study. 21 subjects were assigned to receive a single dose of CR DM 30 mg orally, followed by a 3-day washout period prior to oral administration of CR DM 30 mg every 12 hours for 6 days. Metabolic ratios (MRs) from AUC∞ after single dosing and from AUC0-12h at steady state were taken as the gold standard. The correlations of metabolic ratios of DM to dextrorphan (MRDM/DX) values based on different phenotyping methods were assessed. Linear regression formulas were derived to calculate the antimodes for potential sample methods. In the single-dose part of the study statistically significant correlations were found between MRDM/DX from AUC∞ and from serial plasma points from 1 to 30 hours or from urine (all p-values < 0.001). In the multiple-dose part, statistically significant correlations were found between MRDM/DX from AUC0-12h on day 6 and MRDM/DX from serial plasma points from 0 to 36 hours after the last dosing (all p-values < 0.001). Based on reported urinary antimode and linear regression analysis, the antimodes of AUC and plasma points were derived to profile the trend of antimodes as the drug concentrations changed. MRDM/DX from plasma points had good correlations with MRDM/DX from AUC. Plasma points from 1 to 30 hours after single dose of 30-mg CR DM and any plasma point at steady state after multiple doses of CR DM could potentially be used for phenotyping of CYP2D6.

  12. Limited sampling strategy for determining metformin area under the plasma concentration–time curve

    PubMed Central

    Santoro, Ana Beatriz; Stage, Tore Bjerregaard; Struchiner, Claudio José; Christensen, Mette Marie Hougaard; Brosen, Kim

    2016-01-01

    Aim The aim was to develop and validate limited sampling strategy (LSS) models to predict the area under the plasma concentration–time curve (AUC) for metformin. Methods Metformin plasma concentrations (n = 627) at 0–24 h after a single 500 mg dose were used for LSS development, based on all subsets linear regression analysis. The LSS‐derived AUC(0,24 h) was compared with the parameter ‘best estimate’ obtained by non‐compartmental analysis using all plasma concentration data points. Correlation between the LSS‐derived and the best estimated AUC(0,24 h) (r 2), bias and precision of the LSS estimates were quantified. The LSS models were validated in independent cohorts. Results A two‐point (3 h and 10 h) regression equation with no intercept estimated accurately the individual AUC(0,24 h) in the development cohort: r 2 = 0.927, bias (mean, 95% CI) –0.5, −2.7–1.8% and precision 6.3, 4.9–7.7%. The accuracy of the two point LSS model was verified in study cohorts of individuals receiving single 500 or 1000 mg (r 2 = –0.933–0.934) or seven 1000 mg daily doses (r 2 = 0.918), as well as using data from 16 published studies covering a wide range of metformin doses, demographics, clinical and experimental conditions (r 2 = 0.976). The LSS model reproduced previously reported results for effects of polymorphisms in OCT2 and MATE1 genes on AUC(0,24 h) and renal clearance of metformin. Conclusions The two point LSS algorithm may be used to assess the systemic exposure to metformin under diverse conditions, with reduced costs of sampling and analysis, and saving time for both subjects and investigators. PMID:27324407

  13. An Optimized Method for the Measurement of Acetaldehyde by High-Performance Liquid Chromatography

    PubMed Central

    Guan, Xiangying; Rubin, Emanuel; Anni, Helen

    2011-01-01

    Background Acetaldehyde is produced during ethanol metabolism predominantly in the liver by alcohol dehydrogenase, and rapidly eliminated by oxidation to acetate via aldehyde dehydrogenase. Assessment of circulating acetaldehyde levels in biological matrices is performed by headspace gas chromatography and reverse phase high-performance liquid chromatography (RP-HPLC). Methods We have developed an optimized method for the measurement of acetaldehyde by RP-HPLC in hepatoma cell culture medium, blood and plasma. After sample deproteinization, acetaldehyde was derivatized with 2,4-dinitrophenylhydrazine (DNPH). The reaction was optimized for pH, amount of derivatization reagent,, time and temperature. Extraction methods of the acetaldehyde-hydrazone (AcH-DPN) stable derivative and product stability studies were carried out. Acetaldehyde was identified by its retention time in comparison to AcH-DPN standard, using a new chromatography gradient program, and quantitated based on external reference standards and standard addition calibration curves in the presence and absence of ethanol. Results Derivatization of acetaldehyde was performed at pH 4.0 with a 80-fold molar excess of DNPH. The reaction was completed in 40 min at ambient temperature, and the product was stable for 2 days. A clear separation of AcH-DNP from DNPH was obtained with a new 11-min chromatography program. Acetaldehyde detection was linear up to 80 μM. The recovery of acetaldehyde was >88% in culture media, and >78% in plasma. We quantitatively determined the ethanol-derived acetaldehyde in hepatoma cells, rat blood and plasma with a detection limit around 3 μM. The accuracy of the method was <9% for intraday and <15% for interday measurements, in small volume (70 μl) plasma sampling. Conclusions An optimized method for the quantitative determination of acetaldehyde in biological systems was developed using derivatization with DNPH, followed by a short RP-HPLC separation of AcH-DNP. The method has an extended linear range, is reproducible and applicable to small volume sampling of culture media and biological fluids. PMID:21895715

  14. Development and Validation of Limited-Sampling Strategies for Predicting Amoxicillin Pharmacokinetic and Pharmacodynamic Parameters

    PubMed Central

    Suarez-Kurtz, Guilherme; Ribeiro, Frederico Mota; Vicente, Flávio L.; Struchiner, Claudio J.

    2001-01-01

    Amoxicillin plasma concentrations (n = 1,152) obtained from 48 healthy subjects in two bioequivalence studies were used to develop limited-sampling strategy (LSS) models for estimating the area under the concentration-time curve (AUC), the maximum concentration of drug in plasma (Cmax), and the time interval of concentration above MIC susceptibility breakpoints in plasma (T>MIC). Each subject received 500-mg amoxicillin, as reference and test capsules or suspensions, and plasma concentrations were measured by a validated microbiological assay. Linear regression analysis and a “jack-knife” procedure revealed that three-point LSS models accurately estimated (R2, 0.92; precision, <5.8%) the AUC from 0 h to infinity (AUC0-∞) of amoxicillin for the four formulations tested. Validation tests indicated that a three-point LSS model (1, 2, and 5 h) developed for the reference capsule formulation predicts the following accurately (R2, 0.94 to 0.99): (i) the individual AUC0-∞ for the test capsule formulation in the same subjects, (ii) the individual AUC0-∞ for both reference and test suspensions in 24 other subjects, and (iii) the average AUC0-∞ following single oral doses (250 to 1,000 mg) of various amoxicillin formulations in 11 previously published studies. A linear regression equation was derived, using the same sampling time points of the LSS model for the AUC0-∞, but using different coefficients and intercept, for estimating Cmax. Bioequivalence assessments based on LSS-derived AUC0-∞'s and Cmax's provided results similar to those obtained using the original values for these parameters. Finally, two-point LSS models (R2 = 0.86 to 0.95) were developed for T>MICs of 0.25 or 2.0 μg/ml, which are representative of microorganisms susceptible and resistant to amoxicillin. PMID:11600352

  15. An optimized method for the measurement of acetaldehyde by high-performance liquid chromatography.

    PubMed

    Guan, Xiangying; Rubin, Emanuel; Anni, Helen

    2012-03-01

    Acetaldehyde is produced during ethanol metabolism predominantly in the liver by alcohol dehydrogenase and rapidly eliminated by oxidation to acetate via aldehyde dehydrogenase. Assessment of circulating acetaldehyde levels in biological matrices is performed by headspace gas chromatography and reverse phase high-performance liquid chromatography (RP-HPLC). We have developed an optimized method for the measurement of acetaldehyde by RP-HPLC in hepatoma cell culture medium, blood, and plasma. After sample deproteinization, acetaldehyde was derivatized with 2,4-dinitrophenylhydrazine (DNPH). The reaction was optimized for pH, amount of derivatization reagent, time, and temperature. Extraction methods of the acetaldehyde-hydrazone (AcH-DNP) stable derivative and product stability studies were carried out. Acetaldehyde was identified by its retention time in comparison with AcH-DNP standard, using a new chromatography gradient program, and quantitated based on external reference standards and standard addition calibration curves in the presence and absence of ethanol. Derivatization of acetaldehyde was performed at pH 4.0 with an 80-fold molar excess of DNPH. The reaction was completed in 40 minutes at ambient temperature, and the product was stable for 2 days. A clear separation of AcH-DNP from DNPH was obtained with a new 11-minute chromatography program. Acetaldehyde detection was linear up to 80 μM. The recovery of acetaldehyde was >88% in culture media and >78% in plasma. We quantitatively determined the ethanol-derived acetaldehyde in hepatoma cells, rat blood and plasma with a detection limit around 3 μM. The accuracy of the method was <9% for intraday and <15% for interday measurements, in small volume (70 μl) plasma sampling. An optimized method for the quantitative determination of acetaldehyde in biological systems was developed using derivatization with DNPH, followed by a short RP-HPLC separation of AcH-DNP. The method has an extended linear range, is reproducible and applicable to small-volume sampling of culture media and biological fluids. Copyright © 2011 by the Research Society on Alcoholism.

  16. Determination of D- and L-pipecolic acid in food samples including processed foods.

    PubMed

    Fujita, Toru; Fujita, Manabu; Kodama, Taku; Hada, Toshikazu; Higashino, Kazuya

    2003-01-01

    Pipecolic acid, a metabolite of lysine, is found in human physiological fluids and is thought to play an important role in the central inhibitory gamma-aminobutyric acid system. However, it is unclear whether plasma D- and L-pipecolic acid originate from oral food intake or intestinal bacterial metabolites. We analyzed the contents of D- and L-pipecolic acid in several processed foods including dairy products (cow's milk, cheese and yogurt), fermented beverages (beer and wine) and heated samples (beef, bovine liver, bread and tofu) to clarify the relationship between plasma D- and L-pipecolic acid and dietary foods. Our study revealed that some of the samples contained high concentrations of total pipecolic acid, and a higher proportion of L- than D-isomers. The other samples also showed high proportions of L-pipecolic acid. It was also shown that there is no significant change in the ratio of the D-isomer before and after heat treatment. The heat treatments could not cause the racemization of pipecolic acid in this study. These findings suggest that plasma pipecolic acid, particularly the D-isomer, does not originate from direct food intake and that D- and L-pipecolic acid can possibly be derived from intestinal bacterial metabolites. Copyright 2003 S. Karger AG, Basel

  17. Quantitative Determination of Fluorinated Caffeic Acid Phenethyl Ester Derivative From Rat Blood Plasma by Liquid Chromatography-Electrospray Ionization Tandem Mass Spectrometry

    DTIC Science & Technology

    2008-03-06

    Caffeic acid phenethyl ester (CAPE), a plant-derived polyphenolic compound (Fig. 1), is a component of bee propolis . Propolis has been used as a folk...analytical methods have been documented. These include an HPLC-UV determination of CAPE from a propolis -containing gel [13], HPLC-ESI-MS measurement...of CAPE from crude propolis [14], and HPLC- ESI-MS/MS analysis of CAPE in biological samples [15]. In this paper, we developed a method using ultra

  18. Novel system using microliter order sample volume for measuring arterial radioactivity concentrations in whole blood and plasma for mouse PET dynamic study.

    PubMed

    Kimura, Yuichi; Seki, Chie; Hashizume, Nobuya; Yamada, Takashi; Wakizaka, Hidekatsu; Nishimoto, Takahiro; Hatano, Kentaro; Kitamura, Keishi; Toyama, Hiroshi; Kanno, Iwao

    2013-11-21

    This study aimed to develop a new system, named CD-Well, for mouse PET dynamic study. CD-Well allows the determination of time-activity curves (TACs) for arterial whole blood and plasma using 2-3 µL of blood per sample; the minute sample size is ideal for studies in small animals. The system has the following merits: (1) measures volume and radioactivity of whole blood and plasma separately; (2) allows measurements at 10 s intervals to capture initial rapid changes in the TAC; and (3) is compact and easy to handle, minimizes blood loss from sampling, and delay and dispersion of the TAC. CD-Well has 36 U-shaped channels. A drop of blood is sampled into the opening of the channel and stored there. After serial sampling is completed, CD-Well is centrifuged and scanned using a flatbed scanner to define the regions of plasma and blood cells. The length measured is converted to volume because the channels have a precise and uniform cross section. Then, CD-Well is exposed to an imaging plate to measure radioactivity. Finally, radioactivity concentrations are computed. We evaluated the performance of CD-Well in in vitro measurement and in vivo (18)F-fluorodeoxyglucose and [(11)C]2-carbomethoxy-3β-(4-fluorophenyl) tropane studies. In in vitro evaluation, per cent differences (mean±SE) from manual measurement were 4.4±3.6% for whole blood and 4.0±3.5% for plasma across the typical range of radioactivity measured in mouse dynamic study. In in vivo studies, reasonable TACs were obtained. The peaks were captured well, and the time courses coincided well with the TAC derived from PET imaging of the heart chamber. The total blood loss was less than 200 µL, which had no physiological effect on the mice. CD-Well demonstrates satisfactory performance, and is useful for mouse PET dynamic study.

  19. Nanoplasmonic Quantification of Tumor-derived Extracellular Vesicles in Plasma Microsamples for Diagnosis and Treatment Monitoring

    PubMed Central

    Liang, Kai; Liu, Fei; Fan, Jia; Sun, Dali; Liu, Chang; Lyon, Christopher J.; Bernard, David W.; Li, Yan; Yokoi, Kenji; Katz, Matthew H.; Koay, Eugene J.; Zhao, Zhen; Hu, Ye

    2017-01-01

    Tumour-derived extracellular vesicles (EVs) are of increasing interest as a resource of diagnostic biomarkers. However, most EV assays require large samples, are time-consuming, low-throughput and costly, and thus impractical for clinical use. Here, we describe a rapid, ultrasensitive and inexpensive nanoplasmon-enhanced scattering (nPES) assay that directly quantifies tumor-derived EVs from as little as 1 μL of plasma. The assay uses the binding of antibody-conjugated gold nanospheres and nanorods to EVs captured by EV-specific antibodies on a sensor chip to produce a local plasmon effect that enhances tumour-derived EV detection sensitivity and specificity. We identified a pancreatic cancer EV biomarker, ephrin type-A receptor 2 (EphA2), and demonstrate that an nPES assay for EphA2-EVs distinguishes pancreatic cancer patients from pancreatitis patients and healthy subjects. EphA2-EVs were also informative in staging tumour progression and in detecting early responses to neoadjuvant therapy, with better performance than a conventional enzyme-linked immunosorbent assay. The nPES assay can be easily refined for clinical use, and readily adapted for diagnosis and monitoring of other conditions with disease-specific EV biomarkers. PMID:28791195

  20. Rapid measurement of plasma free fatty acid concentration and isotopic enrichment using LC/MS

    PubMed Central

    Persson, Xuan-Mai T.; Błachnio-Zabielska, Agnieszka Urszula; Jensen, Michael D.

    2010-01-01

    Measurements of plasma free fatty acids (FFA) concentration and isotopic enrichment are commonly used to evaluate FFA metabolism. Until now, gas chromatography-combustion-isotope ratio mass spectrometry (GC/C/IRMS) was the best method to measure isotopic enrichment in the methyl derivatives of 13C-labeled fatty acids. Although IRMS is excellent for analyzing enrichment, it requires time-consuming derivatization steps and is not optimal for measuring FFA concentrations. We developed a new, rapid, and reliable method for simultaneous quantification of 13C-labeled fatty acids in plasma using high-performance liquid chromatography-mass spectrometry (HPLC/MS). This method involves a very quick Dole extraction procedure and direct injection of the samples on the HPLC system. After chromatographic separation, the samples are directed to the mass spectrometer for electrospray ionization (ESI) and analysis in the negative mode using single ion monitoring. By employing equipment with two columns connected parallel to a mass spectrometer, we can double the throughput to the mass spectrometer, reducing the analysis time per sample to 5 min. Palmitate flux measured using this approach agreed well with the GC/C/IRMS method. This HPLC/MS method provides accurate and precise measures of FFA concentration and enrichment. PMID:20526002

  1. Human plasma platelet-derived exosomes: effects of aspirin.

    PubMed

    Goetzl, Edward J; Goetzl, Laura; Karliner, Joel S; Tang, Norina; Pulliam, Lynn

    2016-05-01

    Platelet-derived exosomes mediate platelet atherogenic interactions with endothelial cells and monocytes. A new method for isolation of plasma platelet-derived exosomes is described and used to examine effects of aging and aspirin on exosome cargo proteins. Exosome secretion by purified platelets in vitro did not increase after exposure to thrombin or collagen, as assessed by exosome counts and quantification of the CD81 exosome marker. Thrombin and collagen increased exosome content of α-granule chemokines CXCL4 and CXCL7 and cytoplasmic high-mobility group box 1 (HMGB1) protein, but not membrane platelet glycoprotein VI (GPVI), with dependence on extracellular calcium. Aspirin consumption significantly blocked thrombin- and collagen-induced increases in exosome cargo levels of chemokines and HMGB1, without altering total exosome secretion or GPVI cargo. Plasma platelet-derived exosomes, enriched by absorption with mouse antihuman CD42b [platelet glycoprotein Ib (GPIb)] mAb, had sizes and cargo protein contents similar to those of exosomes from purified platelets. The plasma platelet-derived exosome number is lower and its chemokine and HMGB1 levels higher after age 65 yr. Aspirin consumption significantly suppressed cargo protein levels of plasma platelet-derived exosomes without altering total levels of exosomes. Cargo proteins of human plasma platelet-derived exosomes may biomark platelet abnormalities and in vivo effects of drugs.- Goetzl, E. J., Goetzl, L., Karliner, J. S., Tang, N., Pulliam, L. Human plasma platelet-derived exosomes: effects of aspirin. © FASEB.

  2. Enhancing surface functionality of reduced graphene oxide biosensors by oxygen plasma treatment for Alzheimer's disease diagnosis.

    PubMed

    Chae, Myung-Sic; Kim, Jinsik; Jeong, Dahye; Kim, YoungSoo; Roh, Jee Hoon; Lee, Sung Min; Heo, Youhee; Kang, Ji Yoon; Lee, Jeong Hoon; Yoon, Dae Sung; Kim, Tae Geun; Chang, Suk Tai; Hwang, Kyo Seon

    2017-06-15

    We performed oxygen plasma treatment on reduced graphene oxide (rGO) to improve its surface reactivity with respect to biomolecular interactions. Oxygen-plasma-treated rGO surfaces were employed as reactive interfaces for the detection of amyloid-beta (Aβ) peptides, the pathological hallmarks of Alzheimer's disease (AD), as the target analytes. By measuring the changes in electrical characteristics and confirmation through topographic analysis, the oxygen-plasma-treated rGO sensors had enhanced surface functionality for better antibody immobilization and sensing performance, with a 3.33-fold steeper slope for the electrical responses versus analyte concentration curve (logarithmic scale) compared to the untreated. The elicited biomolecular reactivity of the rGO surfaces with the oxygen plasma treatment remained at 46-51% of the initial value even after aging for 6h in ambient conditions. This phenomenon was also confirmed by pretreating the rGO surfaces with a blocking agent and subsequently subjecting them to antibody immobilization. Finally, the feasibility of the oxygen-plasma-treated rGO sensors as a diagnostic tool was evaluated with clinical samples of neural-derived exosomal Aβ peptides extracted from apparent AD patients and normal controls (NC). In contrast to the untreated sensors (p=0.0460), the oxygen-plasma-treated rGO sensors showed a significant p-value in the identification of clinical samples of AD and NC subjects (p<0.001). These results suggest that oxygen plasma treatment improves sensor performance without complicated fabrication procedures and should aid in the development of novel diagnostic tools based on carbon nanomaterials. Copyright © 2016 Elsevier B.V. All rights reserved.

  3. Identification of low abundance cyclophilins in human plasma.

    PubMed

    Schumann, Michael; Ihling, Christian H; Prell, Erik; Schierhorn, Angelika; Sinz, Andrea; Fischer, Gunter; Schiene-Fischer, Cordelia; Malešević, Miroslav

    2016-11-01

    Cylophilins (Cyps) belong to the ubiquitously distributed enzyme class of peptidyl prolyl cis/trans isomerases (EC5.2.1.8), which are foldases capable of accelerating slow steps in the refolding of denatured proteins. At least 20 different Cyp isoenzymes are broadly distributed among all organs and cellular compartments in humans. Extracellularly localized Cyps came into the scientific focus recently because of their involvement in the control of inflammatory diseases, as well as viral and bacterial infections. However, detailed insights into Cyp functions are often hampered by the lack of sensitive detection methods. We present an improved method for affinity purification and detection of Cyp in biotic samples in this manuscript. The procedure takes advantage of two novel cyclosporine A derivatives. Derivative 1 was used to capture Cyps from the sample while derivative 2 was applied for selective release from the affinity matrix. Using this approach, eight different Cyp (CypA, CypB, CypC, Cyp40 (PPID), CypE, CypD (PPIF), CypH, and CypL1) were unambiguously detected in healthy human blood plasma. Moreover, extracellular CypA was found to be partially modified by N ε acetylation on residues Lys44, Lys133, Lys155, as well as N α  acetylation at the N-terminal Val residue. N α  acetylation of Ser2 residue was also found for Cyp40. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. Isolation of circulating plasma cells from blood of patients diagnosed with clonal plasma cell disorders using cell selection microfluidics.

    PubMed

    Kamande, Joyce W; Lindell, Maria A M; Witek, Małgorzata A; Voorhees, Peter M; Soper, Steven A

    2018-02-19

    Blood samples from patients with plasma cell disorders were analysed for the presence of circulating plasma cells (CPCs) using a microfluidic device modified with monoclonal anti-CD138 antibodies. CPCs were immuno-phenotyped using a CD38/CD56/CD45 panel and identified in 78% of patients with monoclonal gammopathy of undetermined significance (MGUS), all patients with smouldering and symptomatic multiple myeloma (MM), and none in the controls. The burden of CPCs was higher in patients with symptomatic MM compared with MGUS and smouldering MM (p < 0.05). FISH analysis revealed the presence of chromosome 13 deletions in CPCs that correlated with bone marrow results. Point mutations in KRAS were identified, including different mutations from sub-clones derived from the same patient. The microfluidic assay represents a highly sensitive method for enumerating CPCs and allows for the cytogenetic and molecular characterization of CPCs.

  5. Combining image-derived and venous input functions enables quantification of serotonin-1A receptors with [carbonyl-11C]WAY-100635 independent of arterial sampling.

    PubMed

    Hahn, Andreas; Nics, Lukas; Baldinger, Pia; Ungersböck, Johanna; Dolliner, Peter; Frey, Richard; Birkfellner, Wolfgang; Mitterhauser, Markus; Wadsak, Wolfgang; Karanikas, Georgios; Kasper, Siegfried; Lanzenberger, Rupert

    2012-08-01

    image- derived input functions (IDIFs) represent a promising technique for a simpler and less invasive quantification of PET studies as compared to arterial cannulation. However, a number of limitations complicate the routine use of IDIFs in clinical research protocols and the full substitution of manual arterial samples by venous ones has hardly been evaluated. This study aims for a direct validation of IDIFs and venous data for the quantification of serotonin-1A receptor binding (5-HT(1A)) with [carbonyl-(11)C]WAY-100635 before and after hormone treatment. Fifteen PET measurements with arterial and venous blood sampling were obtained from 10 healthy women, 8 scans before and 7 after eight weeks of hormone replacement therapy. Image-derived input functions were derived automatically from cerebral blood vessels, corrected for partial volume effects and combined with venous manual samples from 10 min onward (IDIF+VIF). Corrections for plasma/whole-blood ratio and metabolites were done separately with arterial and venous samples. 5-HT(1A) receptor quantification was achieved with arterial input functions (AIF) and IDIF+VIF using a two-tissue compartment model. Comparison between arterial and venous manual blood samples yielded excellent reproducibility. Variability (VAR) was less than 10% for whole-blood activity (p>0.4) and below 2% for plasma to whole-blood ratios (p>0.4). Variability was slightly higher for parent fractions (VARmax=24% at 5 min, p<0.05 and VAR<13% after 20 min, p>0.1) but still within previously reported values. IDIFs after partial volume correction had peak values comparable to AIFs (mean difference Δ=-7.6 ± 16.9 kBq/ml, p>0.1), whereas AIFs exhibited a delay (Δ=4 ± 6.4s, p<0.05) and higher peak width (Δ=15.9 ± 5.2s, p<0.001). Linear regression analysis showed strong agreement for 5-HT(1A) binding as obtained with AIF and IDIF+VIF at baseline (R(2)=0.95), after treatment (R(2)=0.93) and when pooling all scans (R(2)=0.93), with slopes and intercepts in the range of 0.97 to 1.07 and -0.05 to 0.16, respectively. In addition to the region of interest analysis, the approach yielded virtually identical results for voxel-wise quantification as compared to the AIF. Despite the fast metabolism of the radioligand, manual arterial blood samples can be substituted by venous ones for parent fractions and plasma to whole-blood ratios. Moreover, the combination of image-derived and venous input functions provides a reliable quantification of 5-HT(1A) receptors. This holds true for 5-HT(1A) binding estimates before and after treatment for both regions of interest-based and voxel-wise modeling. Taken together, the approach provides less invasive receptor quantification by full independence of arterial cannulation. This offers great potential for the routine use in clinical research protocols and encourages further investigation for other radioligands with different kinetic characteristics. Copyright © 2012 Elsevier Inc. All rights reserved.

  6. Problems of comparing blood glucose molality and molarity determined with an Omni, an EML 105 and an Ebio analyser.

    PubMed

    Haeckel, Rainer; Hänecke, Petra

    2003-07-01

    The comparability between glucose concentrations measured in various sample systems is still a matter of debate. Decision limits are usually determined in venous plasma and then converted to either blood or to the aqueous compartment (activity). The conversion factors recommended have not yet been generally accepted. In the present study, glucose concentrations were determined in blood and plasma with an Ebio analyser (molarity) and in the aqueous compartment with both an EML 105 and an Omni (molality). All analytical results were referred to the same aqueous standard solution. The Ebio results agreed with reference method values in control materials. Concentrations determined in the various sample systems from patients (molarity) correlated well with the molality values measured either with the EML or the Omni. However, the mean values of the EML were not consistent with those derived theoretically by considering the different water content. With the Omni, only molality values in whole blood appeared plausible, but not in plasma, although the two sample systems should provide identical molality values. The EML results were almost identical in whole blood and plasma. Theoretically, glucose molality would be the ideal diagnostic quantity. However, no diagnostic advantage of molality determined in whole blood with the Omni vs. molarity values could be detected in a group of 40 non-diabetic and 27 diabetic subjects.

  7. Comparative disposition of the nephrotoxicant N-(3, 5-dichlorophenyl)succinimide and the non-nephrotoxicant N-(3, 5-difluorophenyl)succinimide in Fischer 344 rats.

    PubMed

    Henesey, C M; Kellner-Weibel, G L; Tarloff, J B; Harvison, P J

    1999-06-01

    Disposition of the nephrotoxicant N-(3,5-dichlorophenyl)succinimide (NDPS) was compared with that of a nontoxic analog, N-(3, 5-difluorophenyl)succinimide (DFPS). Male Fischer 344 rats were administered 0.2 or 0.6 mmol/kg [14C]NDPS or [14C]DFPS (i.p. in corn oil). Plasma concentrations were determined from blood samples obtained through the carotid artery. Urine samples were analyzed for metabolite content by HPLC. Rats were sacrificed at 3 h (DFPS) or 6 h (NDPS) and tissue radiolabel content and covalent binding were determined. [14C]NDPS-derived plasma radioactivity levels were 6- to 21-fold higher and peaked later than those from [14C]DFPS. Six hours after dosing, NDPS was 40% eliminated in the urine compared with approximately 90% for DFPS. By 48 h, only 67% of the NDPS dose was eliminated in urine. In contrast, DFPS excretion was virtually complete within 24 h. NDPS underwent oxidative metabolism to a slightly greater extent than DFPS. Distribution of [14C]NDPS-derived radioactivity into the kidneys was 3- to 6-fold higher than that into the liver or heart, and was more extensive than with [14C]DFPS. NDPS also covalently bound to plasma, renal, and hepatic proteins to a greater extent than DFPS. In summary, NDPS achieves higher tissue and plasma concentrations, covalently binds to a greater extent, and is eliminated more slowly than DFPS. Differences in the lipid solubility of NDPS metabolites and DFPS metabolites may help explain these results. The overall greater tissue exposure of NDPS and its metabolites may contribute to differential toxicity of these analogs.

  8. Multiplex fluorescent PCR for noninvasive prenatal detection of fetal-derived paternally inherited diseases using circulatory fetal DNA in maternal plasma.

    PubMed

    Tang, Dong-ling; Li, Yan; Zhou, Xin; Li, Xia; Zheng, Fang

    2009-05-01

    To develop a fluorescent polymerase chain reaction (PCR) assay for the detection of circulating fetal DNA in maternal plasma and use the established multiplex in noninvasive prenatal genetic diagnosis and its further applications in forensic casework. The DNA template was extracted from 47 pregnant women and the whole blood samples from the stated biological fathers were used to detect genotype. Using multiplex fluorescent PCR at 16 different polymorphic short tandem repeat (STR) loci, maternal DNA extracted from plasma samples at early pregnancy, medium pregnancy and late pregnancy were used to detect genotype. Their husbands' DNA was also used for fetal genotype ascertainment. Multiplex fluorescent PCR with 16 polymorphic short tandem repeats revealed the presence of fetal DNA in all cases. Every pregnant women/husband pair was informative in at least 3 of 16 loci. The chances of detecting paternally inherited fetal alleles ranged from 66.67 to 94.12%. They are 66.67% in early pregnancy, 85.71% in medium pregnancy and 94.12% in late pregnancy. The accuracy of Multiplex PCR assay to detect fetal DNA was 100%. Circulating fetal DNA analysis can be used as a possible alternative tool in routine laboratory prenatal diagnosis in the near future; this highly polymorphic STR multiplex has greatly improved the chances of detecting paternally inherited fetal alleles compared with other fetal DNA detection systems that use fetus-derived Y sequences to detect only male fetal DNA in maternal plasma. Our proposed technique can be applied to both female and male fetuses, which provides a sensitive, accurate and efficient method for noninvasive prenatal genetic diagnosis and forensic casework.

  9. Micro determination of plasma and erythrocyte copper by atomic absorption spectrophotometry

    PubMed Central

    Blomfield, Jeanette; Macmahon, R. A.

    1969-01-01

    The free and total plasma copper and total erythrocyte copper levels have been determined by simple, yet sensitive and highly specific methods, using atomic absorption spectrophotometry. For total copper determination, the copper was split from its protein combination in plasma or red cells by the action of hydrochloric acid at room temperature. The liberated copper was chelated by ammonium pyrrolidine dithiocarbamate and extracted into n-butyl acetate by shaking and the organic extract was aspirated into the atomic absorption spectrophotometer flame. The entire procedure was carried out in polypropylene centrifuge tubes, capped during shaking. For the free plasma copper measurement the hydrochloric acid step was omitted. Removal of the plasma or erythrocyte proteins was found to be unnecessary, and, in addition, the presence of trichloracetic acid caused an appreciable lowering of absorption. Using a double-beam atomic absorption spectrophotometer and scale expansion × 10, micro methods have been derived for determining the total copper of plasma or erythrocytes with 0·1 ml of sample, and the free copper of plasma with 0·5 ml. The macro plasma copper method requires 2 ml of plasma and is suitable for use with single-beam atomic absorption spectrophotometers. With blood from 50 blood donors, normal ranges of plasma and erythrocyte copper have been determined. PMID:5776543

  10. Plasma in Saturn's Nightside Magnetosphere and the Implications for Global Circulation

    NASA Technical Reports Server (NTRS)

    McAndrews, H.J.; Thomsen, M.F.; Arridge, C.S.; Jackman, C.M.; Wilson, R.J.; Henderson, M.G.; Tokar, R.L.; Khurana, K.K.; Sittler, E. C.; Coates, A.J.; hide

    2009-01-01

    We present a bulk ion flow map from the nightside, equatorial region of Saturn's magnetosphere derived from the Cassini CAPS ion mass spectrometer data. The map clearly demonstrates the dominance of corotation flow over radial flow and suggests that the flux tubes sampled are still closed and attached to the planet up to distances of 50RS. The plasma characteristics in the near-midnight region are described and indicate a transition between the region of the magnetosphere containing plasma on closed drift paths and that containing flux tubes which may not complete a full rotation around the planet. Data from the electron spectrometer reveal two plasma states of high and low density. These are attributed either to the sampling of mass-loaded and depleted flux tubes, respectively, or to the latitudinal structure of the plasma sheet. Depleted, returning flux tubes are not, in general, directly observed in the ions, although the electron observations suggest that such a process must take place in order to produce the low-density population. Flux-tube content is conserved below a limit defined by the mass-loading and magnetic field strength and indicates that the flux tubes sampled may survive their passage through the tail. The conditions for mass-release are evaluated using measured densities, angular velocities and magnetic field strength. The results suggest that for the relatively dense ion populations detectable by the ion mass spectrometer (IMS), the condition for flux-tube breakage has not yet been exceeded. However, the low-density regimes observed in the electron data suggest that loaded flux tubes at greater distances do exceed the threshold for mass-loss and subsequently return to the inner magnetosphere significantly depleted of plasma.

  11. Endothelial Inflammatory Transcriptional Responses Induced by Plasma Following Inhalation of Diesel Emissions

    PubMed Central

    Schisler, Jonathan C.; Ronnebaum, Sarah M.; Madden, Michael; Channell, Meghan M.; Campen, Matthew J.; Willis, Monte S.

    2016-01-01

    Background Air pollution, especially emissions derived from traffic sources, is associated with adverse cardiovascular outcomes. However, it remains unclear how inhaled factors drive extrapulmonary pathology. Objectives Previously, we found that canonical inflammatory response transcripts were elevated in cultured endothelial cells treated with plasma obtained after exposure compared with pre-exposure samples or filtered air (sham) exposures. While the findings confirmed the presence of bioactive factor(s) in the plasma after diesel inhalation, we wanted to better examine the complete genomic response to investigate 1) major responsive transcripts and 2) collected response pathways and ontogeny that may help to refine this method and inform the pathogenesis. Methods We assayed endothelial RNA with gene expression microarrays, examining the responses of cultured endothelial cells to plasma obtained from 6 healthy human subjects exposed to 100 μg/m3 diesel exhaust or filtered air for 2 h on separate occasions. In addition to pre-exposure baseline samples, we investigated samples obtained immediately-post and 24h-post exposure. Results Microarray analysis of the coronary artery endothelial cells challenged with plasma identified 855 probes that changed over time following diesel exhaust exposure. Over-representation analysis identified inflammatory cytokine pathways were upregulated both at the 2 and 24 h condition. Novel pathways related to FOX transcription factors and secreted extracellular factors were also identified in the microarray analysis. Conclusions These outcomes are consistent with our recent findings that plasma contains bioactive and inflammatory factors following pollutant inhalation. The specific study design implicates a novel pathway related to inflammatory blood borne components that may drive the extrapulmonary toxicity of ambient air pollutants. PMID:25942053

  12. Intestinal microbiota-derived metabolomic blood plasma markers for prior radiation injury.

    PubMed

    Ó Broin, Pilib; Vaitheesvaran, Bhavapriya; Saha, Subhrajit; Hartil, Kirsten; Chen, Emily I; Goldman, Devorah; Fleming, William Harv; Kurland, Irwin J; Guha, Chandan; Golden, Aaron

    2015-02-01

    Assessing whole-body radiation injury and absorbed dose is essential for remediation efforts following accidental or deliberate exposure in medical, industrial, military, or terrorist incidents. We hypothesize that variations in specific metabolite concentrations extracted from blood plasma would correlate with whole-body radiation injury and dose. Groups of C57BL/6 mice (n=12 per group) were exposed to 0, 2, 4, 8, and 10.4 Gy of whole-body gamma radiation. At 24 hours after treatment, all animals were euthanized, and both plasma and liver biopsy samples were obtained, the latter being used to identify a distinct hepatic radiation injury response within plasma. A semiquantitative, untargeted metabolite/lipid profile was developed using gas chromatography-mass spectrometry and liquid chromatography-tandem mass spectrometry, which identified 354 biochemical compounds. A second set of C57BL/6 mice (n=6 per group) were used to assess a subset of identified plasma markers beyond 24 hours. We identified a cohort of 37 biochemical compounds in plasma that yielded the optimal separation of the irradiated sample groups, with the most correlated metabolites associated with pyrimidine (positively correlated) and tryptophan (negatively correlated) metabolism. The latter were predominantly associated with indole compounds, and there was evidence that these were also correlated between liver and plasma. No evidence of saturation as a function of dose was observed, as has been noted for studies involving metabolite analysis of urine. Plasma profiling of specific metabolites related to pyrimidine and tryptophan pathways can be used to differentiate whole-body radiation injury and dose response. As the tryptophan-associated indole compounds have their origin in the intestinal microbiome and subsequently the liver, these metabolites particularly represent an attractive marker for radiation injury within blood plasma. Copyright © 2015 Elsevier Inc. All rights reserved.

  13. Quantitative plasma biomarker analysis in HDI exposure assessment.

    PubMed

    Flack, Sheila L; Fent, Kenneth W; Trelles Gaines, Linda G; Thomasen, Jennifer M; Whittaker, Steve; Ball, Louise M; Nylander-French, Leena A

    2010-01-01

    Quantification of amines in biological samples is important for evaluating occupational exposure to diisocyanates. In this study, we describe the quantification of 1,6-hexamethylene diamine (HDA) levels in hydrolyzed plasma of 46 spray painters applying 1,6-hexamethylene diisocyanate (HDI)-containing paint in vehicle repair shops collected during repeated visits to their workplace and their relationship with dermal and inhalation exposure to HDI monomer. HDA was detected in 76% of plasma samples, as heptafluorobutyryl derivatives, and the range of HDA concentrations was < or =0.02-0.92 microg l(-1). After log-transformation of the data, the correlation between plasma HDA levels and HDI inhalation exposure measured on the same workday was low (N = 108, r = 0.22, P = 0.026) compared with the correlation between plasma HDA levels and inhalation exposure occurring approximately 20 to 60 days before blood collection (N = 29, r = 0.57, P = 0.0014). The correlation between plasma HDA levels and HDI dermal exposure measured on the same workday, although statistically significant, was low (N = 108, r = 0.22, P = 0.040) while the correlation between HDA and dermal exposure occurring approximately 20 to 60 days before blood collection was slightly improved (N = 29, r = 0.36, P = 0.053). We evaluated various workplace factors and controls (i.e. location, personal protective equipment use and paint booth type) as modifiers of plasma HDA levels. Workers using a downdraft-ventilated booth had significantly lower plasma HDA levels relative to semi-downdraft and crossdraft booth types (P = 0.0108); this trend was comparable to HDI inhalation and dermal exposure levels stratified by booth type. These findings indicate that HDA concentration in hydrolyzed plasma may be used as a biomarker of cumulative inhalation and dermal exposure to HDI and for investigating the effectiveness of exposure controls in the workplace.

  14. A simple clot based assay for detection of procoagulant cell-derived microparticles.

    PubMed

    Patil, Rucha; Ghosh, Kanjaksha; Shetty, Shrimati

    2016-05-01

    Cell-derived microparticles (MPs) are important biomarkers in many facets of medicine. However, the MP detection methods used till date are costly and time consuming. The main aim of this study was to standardize an in-house clot based screening method for MP detection which would not only be specific and sensitive, but also inexpensive. Four different methods of MP assessment were performed and the results correlated. Using the flow cytometry technique as the gold standard, 25 samples with normal phosphatidylserine (PS) expressing MP levels and 25 samples with elevated levels were selected, which was cross checked by the commercial STA Procoag PPL clotting time (CT) assay. A simple recalcification time and an in-house clot assay were the remaining two tests. The in-house test measures the CT after the addition of calcium chloride to MP rich plasma, following incubation with Russell viper venom and phospholipid free plasma. The CT obtained by the in-house assay significantly correlated with the results obtained by flow cytometry (R2=0.87, p<0.01). Though preliminary, the in-house assay seems to be efficient, inexpensive and promising. It could definitely be utilized routinely for procoagulant MP assessment in various clinical settings.

  15. 68Ga-EDTA PET/CT imaging and plasma clearance for glomerular filtration rate quantification: comparison to conventional 51Cr-EDTA.

    PubMed

    Hofman, Michael; Binns, David; Johnston, Val; Siva, Shankar; Thompson, Mick; Eu, Peter; Collins, Marnie; Hicks, Rodney J

    2015-03-01

    Glomerular filtration rate (GFR) can accurately be determined using (51)Cr-ethylenediaminetetraacetic acid (EDTA) plasma clearance counting but is time-consuming and requires technical skills and equipment not always available in imaging departments. (68)Ga-EDTA can be readily available using an onsite generator, and PET/CT enables both imaging of renal function and accurate camera-based quantitation of clearance of activity from blood and its appearance in the urine. This study aimed to assess agreement between (68)Ga-EDTA GFR ((68)Ga-GFR) and (51)Cr-EDTA GFR ((51)Cr-GFR), using serial plasma sampling and PET imaging. (68)Ga-EDTA and (51)Cr-EDTA were injected concurrently in 31 patients. Dynamic PET/CT encompassing the kidneys was acquired for 10 min followed by 3 sequential 3-min multibed step acquisitions from kidneys to bladder. PET quantification was performed using renal activity at 1-2 min (PETinitial), renal excretion at 2-10 min (PETearly), and, subsequently, urinary excretion into the collecting system and bladder (PETlate). Plasma sampling at 2, 3, and 4 h was performed, with (68)Ga followed by (51)Cr counting after positron decay. The level of agreement for GFR determination was calculated using a Bland-Altman plot and Pearson correlation coefficient (PCC). (51)Cr-GFR ranged from 10 to 220 mL/min (mean, 85 mL/min). There was good agreement between (68)Ga-GFR and (51)Cr-GFR using serial plasma sampling, with a Bland-Altman bias of -14 ± 20 mL/min and a PCC of 0.94 (95% confidence interval, 0.88-0.97). Of the 3 methods used for camera-based quantification, the strongest correlation was for plasma sampling-derived GFR with PETlate (PCC of 0.90; 95% confidence interval, 0.80-0.95). (68)Ga-GFR agreed well with (51)Cr-GFR for estimation of GFR using serial plasma counting. PET dynamic imaging provides a method to estimate GFR without plasma sampling, with the additional advantage of enabling renal imaging in a single study. Additional validation in a larger cohort is warranted to further assess utility. © 2015 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  16. Plasma BDNF Concentration, Val66Met Genetic Variant, and Depression-Related Personality Traits

    PubMed Central

    Terracciano, Antonio; Martin, Bronwen; Ansari, David; Tanaka, Toshiko; Ferrucci, Luigi; Maudsley, Stuart; Mattson, Mark P.; Costa, Paul T.

    2010-01-01

    Brain derived neurotrophic factor (BDNF) regulates synaptic plasticity and neurogenesis, and BDNF plasma and serum levels have been associated with depression, Alzheimer's disease, and other psychiatric and neurodegenerative disorders. In a relatively large community sample, drawn from the Baltimore Longitudinal Study of Aging (BLSA), we examine whether BDNF plasma concentration is associated with the Val66Met functional polymorphism of the BDNF gene (n = 335) and with depression-related personality traits assessed with the NEO-PI-R (n = 391). Plasma concentration of BDNF was not associated with the Val66Met variant in either men or women. However, in men, but not in women, BDNF plasma level was associated with personality traits linked to depression. Contrary to the notion that low BDNF is associated with negative outcomes, we found lower plasma levels in men who score lower on depression and vulnerability to stress (two facets of Neuroticism) and higher on Conscientiousness and Extraversion. These findings challenge the prevailing hypothesis that lower peripheral levels of BDNF are a marker of depression. PMID:20345896

  17. Plasma distributions in meteor head echoes and implications for radar cross section interpretation

    NASA Astrophysics Data System (ADS)

    Marshall, Robert A.; Brown, Peter; Close, Sigrid

    2017-09-01

    The derivation of meteoroid masses from radar measurements requires conversion of the measured radar cross section (RCS) to meteoroid mass. Typically, this conversion passes first through an estimate of the meteor plasma density derived from the RCS. However, the conversion from RCS to meteor plasma density requires assumptions on the radial electron density distribution. We use simultaneous triple-frequency measurements of the RCS for 63 large meteor head echoes to derive estimates of the meteor plasma size and density using five different possible radial electron density distributions. By fitting these distributions to the observed meteor RCS values and estimating the goodness-of-fit, we determine that the best fit to the data is a 1 /r2 plasma distribution, i.e. the electron density decays as 1 /r2 from the center of the meteor plasma. Next, we use the derived plasma distributions to estimate the electron line density q for each meteor using each of the five distributions. We show that depending on the choice of distribution, the line density can vary by a factor of three or more. We thus argue that a best estimate for the radial plasma distribution in a meteor head echo is necessary in order to have any confidence in derived meteoroid masses.

  18. Plasma brain-derived neurotrophic factor in women after bariatric surgery: a pilot study.

    PubMed

    Merhi, Zaher O; Minkoff, Howard; Lambert-Messerlian, Geralyn M; Macura, Jerzy; Feldman, Joseph; Seifer, David B

    2009-04-01

    Eighteen morbidly obese women had plasma brain-derived neurotrophic factor (BDNF) measured before bariatric surgery and 3 months postoperatively. We analyzed plasma BDNF levels in all the participants then subdivided according to menopausal status and type of surgery. Brain-derived neurotrophic factor decreased significantly in all the participants and in the premenopausal group when looked at in isolation.

  19. Experimentally induced mastitis and metritis modulate soy bean derived isoflavone biotransformation in diary cows.

    PubMed

    Kowalczyk-Zieba, I; Woclawek-Potocka, I; Piskula, M K; Piotrowska-Tomala, K K; Boruszewska, D; Bah, M M; Siemieniuch, M J; Skarzynski, D J

    2011-12-01

    The present study compared the changes in isoflavone (daidzein and genistein) and their metabolite (equol and para-ethyl-phenol) concentrations in the blood plasma of cows with induced mastitis and metritis after feeding with soy bean. Sixteen cows were divided into four groups: control for mastitis group, cows with induced mastitis group, control for metritis group, and cows with induced metritis group. All cows were fed a single dose of 2.5 kg of soy bean and then blood samples were taken from the jugular vein for 8 h at predetermined intervals. The concentrations of soy bean-derived isoflavones and their active metabolites were measured in the blood plasma on HPLC system. β-Glucuronidase activity in the blood plasma of cows was measured by fluorometric method. In the blood plasma of cows with induced mastitis and metritis, we found considerably higher concentrations and time-dependent increase in isoflavone metabolites (equol and para-ethyl-phenol) with reference to cyclic cows (P < 0.05). Moreover, we noticed significant decrease of genistein in the blood plasma of the cows with induced metritis compared with control cows (P < 0.05). In addition, in the blood plasma of the cows with induced metritis, we found an increase in β-glucuronidase activity compared with control cows (P < 0.05). In conclusion, health status of the females influenced the concentrations of isoflavone metabolites in the blood plasma of the cows. Experimentally induced mastitis and metritis increased isoflavone absorption, biotransformation and metabolism. Therefore, we suggest that cows with induced mastitis and metritis are more exposed to active isoflavone metabolite actions than healthy cows. Copyright © 2011. Published by Elsevier Inc.

  20. Highly sensitive determination of alendronate in human plasma and dialysate using metal-free HPLC-MS/MS.

    PubMed

    Yamada, Miho; Lee, Xiao-Pen; Fujishiro, Masaya; Iseri, Ken; Watanabe, Makoto; Sakamaki, Hiroshi; Uchida, Naoki; Matsuyama, Takaaki; Kumazawa, Takeshi; Takahashi, Haruo; Ishii, Akira; Sato, Keizo

    2018-01-01

    A highly sensitive method was developed for the analysis of alendronate in human plasma and dialysate using MonoSpin™ SAX ® extraction and metal-free high-performance liquid chromatography (HPLC)-tandem mass spectrometry (MS/MS) following methylation with trimethylsilyldiazomethane. The chromatographic separation of the derivatives for alendronate and alendronate-d 6 was achieved on an L-column2 ODS metal-free column (50 mm  ×  2 mm i.d., particle size 3 µm) with a linear gradient elution system composed of 10 mM ammonium acetate (pH 6.8) and acetonitrile at a flow rate of 0.3 ml/min. Quantification was performed by multiple reaction monitoring (MRM) with positive-ion electrospray ionization (ESI). Distinct peaks were observed for alendronate and for the internal standard on each channel within 1 min. The regression equations showed good linearity within the ranges of 2.0-100 ng/0.5 ml for the plasma and 1.0-100 ng/0.5 ml for the dialysate, with the limits of detection at 1.0 ng/0.5 ml for the plasma and 0.5 ng/0.5 ml for the dialysate. Extraction efficiencies for alendronate for the plasma and dialysate were 41.1-51.2% and 63.6-73.4%, respectively. The coefficient of variation (CV) was ≤8.5%. The method was successfully applied to the analyses of real plasma and dialysate samples derived after intravenous administration of alendronate. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. Metabolic profiling of plasma from sows before parturition and during lactation using a liquid chromatography-mass spectrometry-based approach.

    PubMed

    Hedemann, M S; Flummer, C; Kristensen, N B; Theil, P K

    2012-12-01

    During transition from late gestation to lactation, the sow undergoes large and sudden metabolic changes to adapt from anabolic to catabolic metabolism. Little is known about changes in nutrient uptake and intermediary metabolism of transition sows. This study was undertaken to screen the metabolic profile for qualitative changes in nutrient uptake and metabolism during transition. Four sows were fitted with permanent catheters in artery femoralis (AF), portal vein (PV), and hepatic vein (HV) (sampling sites). Sows were fed a standard lactation diet from 15 d prior to 28 d after parturition. Blood samples were taken 1.5 h after feeding on days -10, -3, 3, and 17 relative to parturition and plasma metabolites were analyzed by a liquid chromatography-mass spectrometry-based approach. Principal components analysis was performed to visualize the metabolic profiles and to screen for intermediary metabolites altered during the transition period. The metabolic profile of sows on day 3 after parturition was distinct from other days. Plasma betaine, Pro, and some unidentified lipid compounds contributed to the separation on day 3; betaine and Pro were lowered by 30% at day 3 compared to day -10 and day -3 (P < 0.001). Plasma choline, Pro, creatine, and unidentified lipid compounds contributed to the separation due to sampling sites. Plasma choline was lowest in HV, intermediate in AF, and highest in PV (P < 0.001) plasma, indicating net absorption from the gastrointestinal tract (PV vs. AF) and liver metabolism (HV vs. PV). The majority of unidentified metabolites found using the loadings plots that were affected by day or sampling site or both were revealed as lipid compounds, that is, bile acid, cholesterol, glycerol, phosphatidyl, sphingomyelin, or acylglycerol derivatives. In conclusion, the intermediary metabolism of sows, especially for fat, changed during transition, and a deeper understanding and detection of involved metabolites are needed to optimize sow feeding during transition.

  2. Non-uniform Erosion and Surface Evolution of Plasma-Facing Materials for Electric Propulsion

    NASA Astrophysics Data System (ADS)

    Matthes, Christopher Stanley Rutter

    A study regarding the surface evolution of plasma-facing materials is presented. Experimental efforts were performed in the UCLA Pi Facility, designed to explore the physics of plasma-surface interactions. The influence of micro-architectured surfaces on the effects of plasma sputtering is compared with the response of planar samples. Ballistic deposition of sputtered atoms as a result of geometric re-trapping is observed. This provides a self-healing mechanism of micro-architectured surfaces during plasma exposure. This result is quantified using a QCM to demonstrate the evolution of surface features and the corresponding influence on the instantaneous sputtering yield. The sputtering yield of textured molybdenum samples exposed to 300 eV Ar plasma is found to be roughly 1 of the 2 corresponding value of flat samples, and increases with ion fluence. Mo samples exhibited a sputtering yield initially as low as 0.22+/-8%, converging to 0.4+/-8% at high fluence. Although the yield is dependent on the initial surface structure, it is shown to be transient, reaching a steady-state value that is independent of initial surface conditions. A continuum model of surface evolution resulting from sputtering, deposition and surface diffusion is also derived to resemble the damped Kuramoto-Sivashinsky (KS) equation of non-linear dynamics. Linear stability analysis of the evolution equation provides an estimate of the selected wavelength, and its dependence on the ion energy and angle of incidence. The analytical results are confirmed by numerical simulations of the equation with a Fast Fourier Transform method. It is shown that for an initially flat surface, small perturbations lead to the evolution of a selected surface pattern that has nano- scale wavelength. When the surface is initially patterned by other means, the final resulting pattern is a competition between the "templated" pattern and the "self-organized" structure. Potential future routes of research are also discussed, corresponding to a design analysis of the current experimental study.

  3. A curve-fitting approach to estimate the arterial plasma input function for the assessment of glucose metabolic rate and response to treatment.

    PubMed

    Vriens, Dennis; de Geus-Oei, Lioe-Fee; Oyen, Wim J G; Visser, Eric P

    2009-12-01

    For the quantification of dynamic (18)F-FDG PET studies, the arterial plasma time-activity concentration curve (APTAC) needs to be available. This can be obtained using serial sampling of arterial blood or an image-derived input function (IDIF). Arterial sampling is invasive and often not feasible in practice; IDIFs are biased because of partial-volume effects and cannot be used when no large arterial blood pool is in the field of view. We propose a mathematic function, consisting of an initial linear rising activity concentration followed by a triexponential decay, to describe the APTAC. This function was fitted to 80 oncologic patients and verified for 40 different oncologic patients by area-under-the-curve (AUC) comparison, Patlak glucose metabolic rate (MR(glc)) estimation, and therapy response monitoring (Delta MR(glc)). The proposed function was compared with the gold standard (serial arterial sampling) and the IDIF. To determine the free parameters of the function, plasma time-activity curves based on arterial samples in 80 patients were fitted after normalization for administered activity (AA) and initial distribution volume (iDV) of (18)F-FDG. The medians of these free parameters were used for the model. In 40 other patients (20 baseline and 20 follow-up dynamic (18)F-FDG PET scans), this model was validated. The population-based curve, individually calibrated by AA and iDV (APTAC(AA/iDV)), by 1 late arterial sample (APTAC(1 sample)), and by the individual IDIF (APTAC(IDIF)), was compared with the gold standard of serial arterial sampling (APTAC(sampled)) using the AUC. Additionally, these 3 methods of APTAC determination were evaluated with Patlak MR(glc) estimation and with Delta MR(glc) for therapy effects using serial sampling as the gold standard. Excellent individual fits to the function were derived with significantly different decay constants (P < 0.001). Correlations between AUC from APTAC(AA/iDV), APTAC(1 sample), and APTAC(IDIF) with the gold standard (APTAC(sampled)) were 0.880, 0.994, and 0.856, respectively. For MR(glc), these correlations were 0.963, 0.994, and 0.966, respectively. In response monitoring, these correlations were 0.947, 0.982, and 0.949, respectively. Additional scaling by 1 late arterial sample showed a significant improvement (P < 0.001). The fitted input function calibrated for AA and iDV performed similarly to IDIF. Performance improved significantly using 1 late arterial sample. The proposed model can be used when an IDIF is not available or when serial arterial sampling is not feasible.

  4. Ectopic bone formation during tissue-engineered cartilage repair using autologous chondrocytes and novel plasma-derived albumin scaffolds.

    PubMed

    Robla Costales, David; Junquera, Luis; García Pérez, Eva; Gómez Llames, Sara; Álvarez-Viejo, María; Meana-Infiesta, Álvaro

    2016-10-01

    The aims of this study were twofold: first, to evaluate the production of cartilaginous tissue in vitro and in vivo using a novel plasma-derived scaffold, and second, to test the repair of experimental defects made on ears of New Zealand rabbits (NZr) using this approach. Scaffolds were seeded with chondrocytes and cultured in vitro for 3 months to check in vitro cartilage production. To evaluate in vivo cartilage production, a chondrocyte-seeded scaffold was transplanted subcutaneously to a nude mouse. To check in vivo repair, experimental defects made in the ears of five New Zealand rabbits (NZr) were filled with chondrocyte-seeded scaffolds. In vitro culture produced mature chondrocytes with no extracellular matrix (ECM). Histological examination of redifferentiated in vitro cultures showed differentiated chondrocytes adhered to scaffold pores. Subcutaneous transplantation of these constructs to a nude mouse produced cartilage, confirmed by histological study. Experimental cartilage repair in five NZr showed cartilaginous tissue repairing the defects, mixed with calcified areas of bone formation. It is possible to produce cartilaginous tissue in vivo and to repair experimental auricular defects by means of chondrocyte cultures and the novel plasma-derived scaffold. Further studies are needed to determine the significance of bone formation in the samples. Copyright © 2016 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  5. Reliability and relative validity of fish consumption data obtained in an exposure assessment study among Montreal-area sportfishers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shatenstein, B.; Kosatsky, T.; Nadon, S.

    1999-02-01

    A two-season exercise was undertaken in 29 high-level sportfish consumers to evaluate the reliability and accuracy of study instruments. Fishers were invited to participate after completing the main study interview (Time 1) in fall 1995 or winter 1996. Over a 4-week period, they provided a nonconsecutive 7-day weighed food record, kept a fish consumption calendar, and responded to a shortened version of the Time 1 instrument at the end of this period (Time 2). A second blood sample (at Time 2) was analyzed for whole blood mercury (Hg) and the omega-3 fatty acids eicosapentanoic acid (EPA) and docosahexaenoic acid (DHA)more » in plasma and erythrocytes. Identical questions were compared in the Time 1 and Time 2 instruments. Reported sportfish consumption assessed by the different instruments was subjected to nutrient analysis. Three estimates of exposure to the target substances were derived from the dietary intake estimates and correlated with their respective Time 2 plasma (EPA, DHA) or blood (Hg) values, and with a kinetically derived interval-specific plasma/blood uptake value. Remarkable similarities were observed for the data derived from like questions in the Time 1 and 2 questionnaires in both seasons. However, frank discrepancies between some portion size estimates and measured values may signal cause for concern.« less

  6. HPLC method for determination of biologically active epoxy-transformers of treosulfan in human plasma: pharmacokinetic application.

    PubMed

    Główka, Franciszek K; Romański, Michał; Teżyk, Artur; Zaba, Czesław; Wróbel, Tomasz

    2012-03-25

    Clinical trials demonstrated treosulfan (TREO) as a promising myeloablative agent prior to hematopoietic stem cell transplantation (HSCT). TREO is a specific pro-drug from which biologically active mono- (S,S-EBDM) and diepoxybutane (S,S-DEB) derivatives are formed in vitro or in vivo by a non-enzymatic pH and temperature-dependent intramolecular nucleophilic substitution. Following extraction of the plasma samples with a mixture of dichloromethane and acetonitrile, S,S-EBDM and S,S-DEB were derivatized with 3-nitrobenzenesulfonic acid (3-NBS) to UV-absorbing esters. Optimal temperature and time of derivatization as well as extraction method and also the effect of pH on TREO stability in plasma were established. Identity of the synthesized derivatives was confirmed by mass spectrometry. The post-derivatization mixture was purified from the excess of unreacted 3-NBS by extraction with water. The derivatization products and 2,2'-dinitrobiphenyl (internal standard) were separated on Nucleosil 100 C18 column using a mobile phase consisted of acetonitrile and water. The developed method was validated and demonstrated adequate accuracy and precision. Limit of quantification for both S,S-EBDM and S,S-DEB amounted to 2.5 μM. The method was applied in clinical conditions to quantify the levels of TREO activation products in plasma of children undergoing HSCT. The methodology for simultaneous determination of TREO epoxy-transformers in human plasma is described for the first time. Copyright © 2011 Elsevier B.V. All rights reserved.

  7. A validated UPLC-MS/MS method for the analysis of linezolid and a novel oxazolidinone derivative (PH027) in plasma and its application to tissue distribution study in rabbits.

    PubMed

    Hedaya, Mohsen A; Thomas, Vidhya; Abdel-Hamid, Mohamed E; Kehinde, Elijah O; Phillips, Oludotun A

    2017-01-01

    Linezolid is the first approved oxazolidinone antibacterial agent, whereas PH027 is a novel compound of the same class that exhibits good in vitro antibacterial activity. The objective of this study was to develop an UPLC-MS/MS assay for the analysis of linezolid and PH027 in plasma and to apply the method for comparative pharmacokinetic and tissue distribution studies of both compounds. Plasma samples and calibrators were extracted with diethyl ether after addition of the internal standard solution. After evaporation of the ether layer, the residue was reconstituted in mobile phase and injected into UPLC-MS/MS. The mobile phase consisted of 2mM ammonium acetate buffer solution and acetonitrile (70:30) at a flow rate of 0.2ml/min. Separation was achieved using UPLC BEH C 18 column, and quantitative determination of the analytes was performed using multiple-reaction monitoring (MRM) scanning mode. The method was validated by analyzing quality control tissue homogenate samples, and was applied to analyze tissue homogenate samples obtained following IV injections of linezolid and PH027 in rabbits. The developed UPLC-MS/MS method was linear in the concentration range of 50-5000ng/ml. Validation of the method proved that the method's precision, selectivity and stability were all within the acceptable limits. Linezolid and PH027 concentrations were accurately determined in the quality control tissue homogenate samples, and analysis of samples obtained following IV administration of the two compounds showed that the tissue to plasma concentration ratio of PH027 was higher than that of linezolid probably due to its higher lipophilicity. The developed UPLC-MS/MS method for the analysis of linezolid and PH027 in rabbit's plasma can accurately determine the concentrations of these compounds in different tissues. Copyright © 2016 Elsevier B.V. All rights reserved.

  8. Plasma levels of hypoxia-regulated factors in patients with age-related macular degeneration.

    PubMed

    Ioanna, Zygoula; Christian, Schori; Christian, Grimm; Daniel, Barthelmes

    2018-02-01

    Various hypoxia-related proteins are differentially expressed in the retina and secreted to the vitreous and/or aqueous humor of patients affected by dry or neovascular age-related macular degeneration (nAMD). To determine whether these conditions alter concentrations of cytokines also in the systemic circulation, we measured plasma levels of six hypoxia-related proteins. Plasma was prepared from EDTA blood that was collected from patients affected by dry AMD (n = 5), nAMD (n = 11), proliferative diabetic retinopathy (PDR; n = 9), and patients with an epiretinal membrane (ERM; n = 11). ERM samples served as negative controls, PDR samples as positive controls. Protein concentrations of vascular endothelial growth factor (VEGF), erythropoietin (EPO), angiopoietin-like 4 (ANGPTL4), placental growth factor (PlGF), tumor necrosis factor alpha (TNF-α), and pigment epithelium-derived factor (PEDF) were determined by enzyme-linked immunosorbent assay (ELISA). The concentration of PlGF was significantly increased in plasma of patients affected by nAMD. Although no statistically significant differences were found for EPO, ANGPTL4, PlGF, TNF-α, and PEDF, the mean concentration of VEGF was lowest in the nAMD group. Plasma concentrations of the six factors did not correlate with gender or age of patients. nAMD may increase plasma concentrations of PlGF, making it a candidate as a biomarker for the neovascular form of AMD. Other factors, however, were not differentially regulated, suggesting that their systemic concentrations are not generally increased in hypoxia-related retinal diseases.

  9. Pairwise alignment of chromatograms using an extended Fisher-Rao metric.

    PubMed

    Wallace, W E; Srivastava, A; Telu, K H; Simón-Manso, Y

    2014-09-02

    A conceptually new approach for aligning chromatograms is introduced and applied to examples of metabolite identification in human blood plasma by liquid chromatography-mass spectrometry (LC-MS). A square-root representation of the chromatogram's derivative coupled with an extended Fisher-Rao metric enables the computation of relative differences between chromatograms. Minimization of these differences using a common dynamic programming algorithm brings the chromatograms into alignment. Application to a complex sample, National Institute of Standards and Technology (NIST) Standard Reference Material 1950, Metabolites in Human Plasma, analyzed by two different LC-MS methods having significantly different ranges of elution time is described. Published by Elsevier B.V.

  10. Tests of positive ion beams from a microwave ion source for AMS

    NASA Astrophysics Data System (ADS)

    Schneider, R. J.; von Reden, K. F.; Hayes, J. M.; Wills, J. S. C.; Kern, W. G. E.; Kim, S.-W.

    2000-10-01

    A test facility has been constructed to evaluate high-current positive ion beams from small gaseous samples for AMS applications. The major components include a compact permanent magnet microwave ion source built at the AECL Chalk River Laboratory and now on loan from the University of Toronto, and a double-focusing spectrometer magnet on loan from Argonne National Laboratory. Samples are introduced by means of a silica capillary injection system. Loop injection into a carrier gas provides a stable feed for the microwave driven plasma. The magnetic analysis system is utilized to isolate carbon ions derived from CO 2 samples from other products of the plasma discharge, including argon ions of the carrier gas. With a smaller discharge chamber, we hope to exceed a conversion efficiency of 14% for carbon ions produced per atom, which we reported at AMS-7. The next step will be to construct an efficient charge-exchange cell, to produce negative ions for injection into the WHOI recombinator injector.

  11. Covariant relativistic hydrodynamics of multispecies plasma and generalized Ohm's law

    NASA Astrophysics Data System (ADS)

    Gedalin, Michael

    1996-04-01

    Fully covariant hydrodynamical equations for a multispecies relativistic plasma in an external electromagnetic field are derived. The derived multifluid description takes into account binary Coulomb collisions, annihilation, and interaction with the photon background in terms of the invariant collision cross sections. A generalized Ohm's law is derived in a manifestly covariant form. Particular attention is devoted to the relativistic electron-positron plasma.

  12. Development of a magnetic bead-based method for the collection of circulating extracellular vesicles.

    PubMed

    Shih, Chun-Liang; Chong, Kowit-Yu; Hsu, Shih-Che; Chien, Hsin-Jung; Ma, Ching-Ting; Chang, John Wen-Cheng; Yu, Chia-Jung; Chiou, Chiuan-Chian

    2016-01-25

    Cells release different types of extracellular vesicles (EVs). These EVs contain biomolecules, including proteins and nucleic acids, from their parent cells, which can be useful for diagnostic applications. The aim of this study was to develop a convenient procedure to collect circulating EVs with detectable mRNA or other biomolecules. Magnetic beads coated with annexin A5 (ANX-beads), which bound to phosphatidylserine moieties on the surfaces of most EVs, were tested for their ability to capture induced apoptotic bodies in vitro and other phosphatidylserine-presenting vesicles in body fluids. Our results show that up to 60% of induced apoptotic bodies could be captured by the ANX-beads. The vesicles captured from cultured media or plasma contained amplifiable RNA. Suitable blood samples for EV collection included EDTA-plasma and serum but not heparin-plasma. In addition, EVs in plasma were labile to freeze-and-thaw cycles. In rodents xenografted with human cancer cells, tumor-derived mRNA could be detected in EVs captured from serum samples. Active proteins could be detected in EVs captured from ascites but not from plasma. In conclusion, we have developed a magnetic bead-based procedure for the collection of EVs from body fluids and proved that captured EVs contain biomolecules from their parent cells, and therefore have great potential for disease diagnosis. Copyright © 2015 Elsevier B.V. All rights reserved.

  13. Plasma chemistry reference values in ostriches.

    PubMed

    Verstappen, F A L M; Lumeij, J T; Bronneberg, R G G

    2002-01-01

    Reference values for 18 plasma chemical variables in blue neck ostriches (Struthio camelus australis, n = 60, age 24-36 mo) were established for use in veterinary clinical practice using nonparametric statistics. The following values were established for the percentiles P2.5 and P97.5: sodium 147-157 mmol/L, calcium 2.4-4.8 mmol/L, inorganic phosphate 1.3-2.3 mmol/L, chloride 94-105 mmol/L, glucose 10.3-13.7 mmol/L, urea 0.5-0.8 mmol/L, uric acid 351-649 mumol/L, bile acids 8-33 mumol/L, total protein 39-56 g/L, albumin-globulin ratio 0.45-0.59, osmolality 304-330 mOsm/kg, alkaline phosphate 69-217 IU/L, aspartate aminotransferase 243-418 IU/L, gamma-glutamyltransferase 0-1 IU/L, creatine kinase 1648-4894 IU/L, glutamate dehydrogenase 8-17 IU/L, and lactate dehydrogenase 860-2236 IU/L. The plasma calcium concentration was significantly (P < 0.001; r = 0.74) related to the total protein concentration and an adjustment-formula for calcium was derived: adjusted Ca (mmol/L) = Ca (mmol/L)--0.09 TP (g/L) + 4.4. The influence of blood sample treatment on the plasma potassium concentration as seen in other avian species was demonstrated in a separate experiment, emphasizing the need to separate plasma and cells immediately after collection in avian blood samples.

  14. Appearance of Drug Resistance-Associated Mutations in Human Immunodeficiency Virus Type 1 CRF01_AE Integrase Derived from Drug-Naive Thai Patients.

    PubMed

    Isarangkura-Na-Ayuthaya, Panasda; Kaewnoo, Wiyada; Auwanit, Wattana; de Silva, U Chandimal; Ikuta, Kazuyoshi; Sawanpanyalert, Pathom; Kameoka, Masanori

    2010-12-01

    CRF01_AE is a major subtype of human immunodeficiency virus type 1 (HIV-1) circulating in Southeast Asia, including Thailand. We performed genotypic studies on HIV-1 CRF01_AE integrase derived from plasma samples from drug-naive Thai patients. Direct sequencing of amplified CRF01_AE integrase genes revealed that although no primary mutations associated with drug resistance to integrase inhibitors were detected, at least one secondary mutation was found in 96% of samples. Our results indicate that the impact of these mutations on the baseline drug susceptibility of CRF01_AE viruses to integrase inhibitors may need to be addressed prior to the introduction of these drugs in Southeast Asian countries, including Thailand.

  15. Distribution of Parvovirus B19 DNA in Blood Compartments and Persistence of Virus in Blood Donors

    PubMed Central

    Lee, Tzong-Hae; Kleinman, Steven H.; Wen, Li; Montalvo, Lani; Todd, Deborah S.; Wright, David J.; Tobler, Leslie H.; Busch, Michael P.

    2013-01-01

    Introduction Because the receptor for Parvovirus B19 (B19V) is on erythrocytes, we investigated B19V distribution in blood by in-vitro spiking experiments and evaluated viral compartmentalization and persistence in natural infection. Methods Two whole blood protocols (ultracentrifugation and a rapid RBC lysis/removal protocol) were evaluated using quantitative real-time PCR. Whole blood (WB) was spiked with known concentrations of B19V and recovery in various blood fractions was determined. The rapid RBC lysis/removal protocol was then used to compare B19V concentrations in 104 paired whole blood and plasma samples collected longitudinally from 43 B19V infected donors with frozen specimens in the REDS Allogeneic Donor and Recipient Repository (RADAR). Results In B19V spiking experiments, ~one-third of viral DNA was recovered in plasma and two-thirds was loosely bound to erythrocytes. In the IgM positive stage of infection in blood donors when plasma B19V DNA concentrations were > 100 IU/mL, median DNA concentrations were ~30-fold higher in WB than in plasma. In contrast, when IgM was absent and when the B19V DNA concentration was lower, the median whole blood to plasma ratio was ~1. Analysis of longitudinal samples demonstrated persistent detection of B19V in WB but declining ratios of WB/plasma B19V with declining plasma VL levels and loss of IgM-reactivity. Conclusions The WB/plasma B19V DNA ratio varies by stage of infection. Further study is required to determine if this is related to the presence of circulating DNA-positive erythrocytes derived from B19V infected erythroblasts, B19V-specific IgM mediated binding of virus to cells, or other factors. PMID:21303368

  16. Small RNA profiling of low biomass samples: identification and removal of contaminants

    DOE PAGES

    Heintz-Buschart, Anna; Yusuf, Dilmurat; Kaysen, Anne; ...

    2018-05-14

    Here, sequencing-based analyses of low-biomass samples are known to be prone to misinterpretation due to the potential presence of contaminating molecules derived from laboratory reagents and environments. DNA contamination has been previously reported, yet contamination with RNA is usually considered to be very unlikely due to its inherent instability. Small RNAs (sRNAs) identified in tissues and bodily fluids, such as blood plasma, have implications for physiology and pathology, and therefore the potential to act as disease biomarkers. Thus, the possibility for RNA contaminants demands careful evaluation.

  17. Small RNA profiling of low biomass samples: identification and removal of contaminants

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Heintz-Buschart, Anna; Yusuf, Dilmurat; Kaysen, Anne

    Here, sequencing-based analyses of low-biomass samples are known to be prone to misinterpretation due to the potential presence of contaminating molecules derived from laboratory reagents and environments. DNA contamination has been previously reported, yet contamination with RNA is usually considered to be very unlikely due to its inherent instability. Small RNAs (sRNAs) identified in tissues and bodily fluids, such as blood plasma, have implications for physiology and pathology, and therefore the potential to act as disease biomarkers. Thus, the possibility for RNA contaminants demands careful evaluation.

  18. Human Plasma-derived Polymeric IgA and IgM Antibodies Associate with Secretory Component to Yield Biologically Active Secretory-like Antibodies*

    PubMed Central

    Longet, Stéphanie; Miled, Sarah; Lötscher, Marius; Miescher, Sylvia M.; Zuercher, Adrian W.; Corthésy, Blaise

    2013-01-01

    Immunotherapy with monoclonal and polyclonal immunoglobulin is successfully applied to improve many clinical conditions, including infection, autoimmune diseases, or immunodeficiency. Most immunoglobulin products, recombinant or plasma-derived, are based on IgG antibodies, whereas to date, the use of IgA for therapeutic application has remained anecdotal. In particular, purification or production of large quantities of secretory IgA (SIgA) for potential mucosal application has not been achieved. In this work, we sought to investigate whether polymeric IgA (pIgA) recovered from human plasma is able to associate with secretory component (SC) to generate SIgA-like molecules. We found that ∼15% of plasma pIgA carried J chain and displayed selective SC binding capacity either in a mixture with monomeric IgA (mIgA) or after purification. The recombinant SC associated covalently in a 1:1 stoichiometry with pIgA and with similar efficacy as colostrum-derived SC. In comparison with pIgA, the association with SC delayed degradation of SIgA by intestinal proteases. Similar results were obtained with plasma-derived IgM. In vitro, plasma-derived IgA and SIgA neutralized Shigella flexneri used as a model pathogen, resulting in a delay of bacteria-induced damage targeted to polarized Caco-2 cell monolayers. The sum of these novel data demonstrates that association of plasma-derived IgA or IgM with recombinant/colostrum-derived SC is feasible and yields SIgA- and SIgM-like molecules with similar biochemical and functional characteristics as mucosa-derived immunoglobulins. PMID:23250751

  19. Increase of EPA-derived hydroxy, epoxy and dihydroxy fatty acid levels in human plasma after a single dose of long-chain omega-3 PUFA.

    PubMed

    Schuchardt, Jan Philipp; Schneider, Inga; Willenberg, Ina; Yang, Jun; Hammock, Bruce D; Hahn, Andreas; Schebb, Nils Helge

    2014-06-01

    Several supplementation studies with long-chain omega-3 polyunsaturated fatty acids (LC n-3 PUFA) describe an increase of EPA-derived hydroxy, epoxy and dihydroxy fatty acids in blood, while changes in levels of other LC n-3 and n-6 PUFA-derived oxylipins were minor. In order to investigate the kinetics of changes in oxylipin levels in response to LC n-3 PUFA ingestion, we conducted a single dose treatment study with healthy subjects. In the present kinetic study, we compared patterns of hydroxy, epoxy and dihydroxy fatty acids in plasma of 6 healthy men before and after 6, 8, 24, and 48h of fish oil (1008mg EPA and 672mg DHA) ingestion. Levels of EPA- as well as other LC PUFA-derived hydroxy, epoxy and dihydroxy fatty acids were analyzed in plasma by LC-MS. Additionally, levels of these oxylipins were compared with their parent PUFA levels in plasma phospholipids. All EPA-derived oxylipin levels were significantly increased 6h after LC n-3 PUFA ingestion and gradually drop thereafter reaching the baseline levels about 48h after treatment. The relative increase in EPA plasma phospholipid levels highly correlated with the increase of plasma EPA-derived oxylipin levels at different time points. In contrast, plasma levels of arachidonic acid- and DHA-derived oxylipins as well as parent PUFA levels in plasma phospholipids were hardly changed. Our findings demonstrate that a single dose of LC n-3 PUFAs can rapidly induce a shift in the EPA oxylipin profile of healthy subjects within a few hours. Taking the high biological activity of the EPA-derived epoxy fatty acids into account, even short-term treatment with LC n-3 PUFAs may cause systemic effects, which warrant further investigation. Copyright © 2014 Elsevier Inc. All rights reserved.

  20. Langmuir-Probe Measurements in Flowing-Afterglow Plasmas

    NASA Technical Reports Server (NTRS)

    Johnsen, R.; Shunko, E. V.; Gougousi, T.; Golde, M. F.

    1994-01-01

    The validity of the orbital-motion theory for cylindrical Langmuir probes immersed in flowing- afterglow plasmas is investigated experimentally. It is found that the probe currents scale linearly with probe area only for electron-collecting but not for ion-collecting probes. In general, no agreement is found between the ion and electron densities derived from the probe currents. Measurements in recombining plasmas support the conclusion that only the electron densities derived from probe measurements can be trusted to be of acceptable accuracy. This paper also includes a brief derivation of the orbital-motion theory, a discussion of perturbations of the plasma by the probe current, and the interpretation of plasma velocities obtained from probe measurements.

  1. Protein expression profiles of human lymph and plasma mapped by 2D-DIGE and 1D SDS–PAGE coupled with nanoLC–ESI–MS/MS bottom-up proteomics

    PubMed Central

    Clement, Cristina C.; Aphkhazava, David; Nieves, Edward; Callaway, Myrasol; Olszewski, Waldemar; Rotzschke, Olaf; Santambrogio, Laura

    2013-01-01

    In this study a proteomic approach was used to define the protein content of matched samples of afferent prenodal lymph and plasma derived from healthy volunteers. The analysis was performed using two analytical methodologies coupled with nanoliquid chromatography-tandem mass spectrometry: one-dimensional gel electrophoresis (1DEF nanoLC Orbitrap–ESI–MS/MS), and two-dimensional fluorescence difference-in-gel electrophoresis (2D-DIGE nanoLC–ESI–MS/MS). The 253 significantly identified proteins (p<0.05), obtained from the tandem mass spectrometry data, were further analyzed with pathway analysis (IPA) to define the functional signature of prenodal lymph and matched plasma. The 1DEF coupled with nanoLC–MS–MS revealed that the common proteome between the two biological fluids (144 out of 253 proteins) was dominated by complement activation and blood coagulation components, transporters and protease inhibitors. The enriched proteome of human lymph (72 proteins) consisted of products derived from the extracellular matrix, apoptosis and cellular catabolism. In contrast, the enriched proteome of human plasma (37 proteins) consisted of soluble molecules of the coagulation system and cell–cell signaling factors. The functional networks associated with both common and source-distinctive proteomes highlight the principal biological activity of these immunologically relevant body fluids. PMID:23202415

  2. Characterizing amino-acid biosignatures amongst individuals with schizophrenia: a case-control study.

    PubMed

    Cao, Bing; Wang, Dongfang; Brietzke, Elisa; McIntyre, Roger S; Pan, Zihang; Cha, Danielle; Rosenblat, Joshua D; Zuckerman, Hannah; Liu, Yaqiong; Xie, Qing; Wang, Jingyu

    2018-05-23

    Amino acids and derivatives participate in the biosynthesis and downstream effects of numerous neurotransmitters. Variations in specific amino acids have been implicated in the pathophysiology of schizophrenia. Herein, we sought to compare levels of amino acids and derivatives between subjects with schizophrenia and healthy controls (HC). Two hundred and eight subjects with Diagnostic and Statistical Manual of Mental Disorders, Fourth Edition criteria (DSM-IV)-defined schizophrenia and 175 age- and sex-matched HC were enrolled. The levels of twenty-five amino acids and seven related derivatives were measured in plasma samples using hydrophilic interaction liquid chromatography (HILIC) liquid chromatography-tandem mass spectrometry (LC-MS). After controlling for age, sex and body mass index (BMI), four amino acids and derivatives (i.e., cysteine, GABA, glutamine and sarcosine) were observed to be higher in the schizophrenia group when compared with HC; seven amino acids and derivatives were lower in the schizophrenia group (i.e., arginine, L-ornithine, threonine, taurine, tryptophan, methylcysteine, and kynurenine). Statistically significant differences in plasma amino-acid profiles between subjects with first-episode vs. recurrent schizophrenia for aspartate and glutamine were also demonstrated using generalized linear models controlling for age, sex, and BMI. The differences in amino acids and derivatives among individuals with schizophrenia when compared to HC may represent underlying pathophysiology, including but not limited to dysfunctional proteinogenic processes, alterations in excitatory and inhibitory neurotransmission, changes in ammonia metabolism and the urea cycle. Taken together, amino-acid profiling may provide a novel stratification approach among individuals with schizophrenia.

  3. Evaluation of the bioavailability and metabolism in the rat of punicalagin, an antioxidant polyphenol from pomegranate juice.

    PubMed

    Cerdá, Begoña; Llorach, Rafael; Cerón, José J; Espín, Juan Carlos; Tomás-Barberán, Francisco A

    2003-01-01

    Punicalagin is an antioxidant ellagitannin of pomegranate juice. This compound is responsible for the high antioxidant activity of this juice. Nothing is known about the bioavailability and metabolism of punicalagin or other food ellagitannins. The present work aims to evaluate the bioavailability and metabolism of punicalagin in the rat as an animal model. Two groups of rats were studied. One fed with standard rat diet (n = 5) and another with the same diet plus 6 % punicalagin (n = 5). Samples of urine and faeces were taken during 37 days and plasma every week. The different metabolites were analysed by HPLC-MS-MS. The daily intake of punicalagin ranged from 0.6 to 1.2 g. Values around 3-6 % the ingested punicalagin were excreted as identified metabolites in faeces and urine. In faeces, punicalagin is transformed to hydrolysis products and partly metabolites by the rat microflora to 6H-dibenzo[b,d]pyran-6-one derivatives. In plasma, punicalagin was detected at concentrations around 30 microg/mL, and glucuronides of methyl ether derivatives of ellagic acid were also detected. 6H-Dibenzo[b,d]pyran-6-one derivatives were also detected especially during the last few weeks of the experiment. In urine, the main metabolites observed were the 6H-dibenzo[b,d]pyran-6-one derivatives, as aglycones or glucuronides. As only 3-6 % of the ingested punicalagin was detected as such or as metabolites in urine and faeces, the majority of this ellagitannin has to be converted to undetectable metabolites (i. e. CO(2)) or accumulated in non-analysed tissues, however with only traces of punicalagin metabolites being detected in liver or kidney. This is the first report on the absorption of an ellagitannin and its presence in plasma. In addition, the transformation of ellagic acid derivatives to 6H-dibenzo[b,d]pyran-6-one derivatives in the rat is also confirmed.

  4. Development and full validation of an UPLC-MS/MS method for the quantification of the plant-derived alkaloid indirubin in rat plasma.

    PubMed

    Jähne, Evelyn A; Sampath, Chethan; Butterweck, Veronika; Hamburger, Matthias; Oufir, Mouhssin

    2016-09-05

    An UPLC-MS/MS method for the quantification of indirubin in lithium heparinized rat plasma was developed and validated according to current international guidelines. Indirubin was extracted from rat plasma by using Waters Ostro™ pass-through sample preparation plates. The method was validated with a LLOQ of 5.00ng/mL and an ULOQ of 500ng/mL. The calibration curve was fitted by least-square quadratic regression, and a weighting factor of 1/X was applied. Recoveries of indirubin and I.S. were consistent and ≥75.5%. Stability studies demonstrated that indirubin was stable in lithium heparinized rat plasma for at least 3 freeze/thaw cycles, for 3h at RT, for 96h in the autosampler at 10°C, and for 84days when stored below -65°C. Preliminary pharmacokinetic (PK) data were obtained from Sprague Dawley rats after intravenous administration of indirubin (2mg/kg b.w.) and blood sampling up to 12h after injection. PK parameters were determined by non-compartmental analysis. Indirubin had a half-life (t1/2) of 35min, and a relatively high clearance (CL) of 2.71L/h/kg. Copyright © 2016 Elsevier B.V. All rights reserved.

  5. Quantification of fetal and total circulatory DNA in maternal plasma samples before and after size fractionation by agarose gel electrophoresis.

    PubMed

    Hromadnikova, I; Zejskova, L; Doucha, J; Codl, D

    2006-11-01

    Fetal extracellular DNA is mainly derived from apoptotic bodies of trophoblast. Recent studies have shown size differences between fetal and maternal extracellular DNA. We have examined the quantification of fetal (SRY gene) and total (GLO gene) extracellular DNA in maternal plasma in different fractions (100-300, 300-500, 500-700, 700-900, and >900 bp) after size fractionation by agarose gel electrophoresis. DNA was extracted from maternal plasma samples from 11 pregnant women carrying male foetuses at the 16th week of gestation. Fetal circulatory DNA was mainly detected in the 100-300 bp fraction with the median concentration being 14.4 GE/ml. A lower median amount of 4.9 GE/ml was also found in the 300-500 bp fraction. Circulatory DNA extracted from the 100-300 bp fraction contained 4.2 times enriched fetal DNA when compared with unseparated DNA sample. Fetal DNA within the 300-500 bp fraction was 2.5 times enriched. Circulatory fetal DNA is predominantly present in a fraction with molecular size <500 bp, which can be used for the detection of paternally inherited alleles. However, the usage of size-separated DNA is not suitable for routine clinical applications because of risk of contamination.

  6. Kinetic analysis of spin current contribution to spectrum of electromagnetic waves in spin-1/2 plasma. I. Dielectric permeability tensor for magnetized plasmas

    NASA Astrophysics Data System (ADS)

    Andreev, Pavel A.

    2017-02-01

    The dielectric permeability tensor for spin polarized plasmas is derived in terms of the spin-1/2 quantum kinetic model in six-dimensional phase space. Expressions for the distribution function and spin distribution function are derived in linear approximations on the path of dielectric permeability tensor derivation. The dielectric permeability tensor is derived for the spin-polarized degenerate electron gas. It is also discussed at the finite temperature regime, where the equilibrium distribution function is presented by the spin-polarized Fermi-Dirac distribution. Consideration of the spin-polarized equilibrium states opens possibilities for the kinetic modeling of the thermal spin current contribution in the plasma dynamics.

  7. Effects of Chitosan Derivative N-[(2-Hydroxy-3-Trimethylammonium)Propyl]Chloride on Anticoagulant Activity of Guinea Pig Plasma.

    PubMed

    Drozd, N N; Shagdarova, B Ts; Il'ina, A V; Varlamov, V P

    2017-07-01

    Intravenous injection of protamine sulfate or quarternized chitosan derivative to guinea pigs after injection of 70 aIIa U/kg non-fractionated heparin shortened plasma clotting time (shown by partial activated thromboplastin time, thrombin time, and prothrombin time). Intravenous injection of protamine sulfate or quarternized chitosan derivative to guinea pigs after injection of 1 mg/kg (100 aXa U/kg) low-molecular-weight heparin (clexane) led to shortening of plasma clotting time in the ReaClot Heparin test and to prolongation of plasma amidolytic activity in the factor Xa chromogenic substrate test.

  8. Using droplet digital PCR to analyze MYCN and ALK copy number in plasma from patients with neuroblastoma.

    PubMed

    Lodrini, Marco; Sprüssel, Annika; Astrahantseff, Kathy; Tiburtius, Daniela; Konschak, Robert; Lode, Holger N; Fischer, Matthias; Keilholz, Ulrich; Eggert, Angelika; Deubzer, Hedwig E

    2017-10-17

    The invasive nature of surgical biopsies deters sequential application, and single biopsies often fail to reflect tumor dynamics, intratumor heterogeneity and drug sensitivities likely to change during tumor evolution and treatment. Implementing molecular characterization of cell-free neuroblastoma-derived DNA isolated from blood plasma could improve disease assessment for treatment selection and monitoring of patients with high-risk neuroblastoma. We established droplet digital PCR (ddPCR) protocols for MYCN and ALK copy number status in plasma from neuroblastoma patients. Our ddPCR protocol accurately discriminated between MYCN and ALK amplification, gain and normal diploid status in a large panel of neuroblastoma cell lines, and discrepancies with reported MYCN and ALK status were detected, including a high-level MYCN amplification in NB-1, a MYCN gain in SH-SY5Y, a high-level ALK amplification in IMR-32 and ALK gains in BE(2)-C, Kelly, SH-SY5Y and LAN-6. MYCN and ALK status were also reliably determined from cell-free DNA derived from medium conditioned by the cell lines. MYCN and ALK copy numbers of subcutaneous neuroblastoma xenograft tumors were accurately determined from cell-free DNA in the mouse blood plasma. In a final validation step, we accurately distinguished MYCN and ALK copy numbers of the corresponding primary tumors using retrospectively collected blood plasma samples from 10 neuroblastoma patients. Our data justify the further development of molecular disease characterization using cell-free DNA in blood plasma from patients with neuroblastoma. This expanded molecular diagnostic palette may improve monitoring of disease progression including relapse and metastatic events as well as therapy success or failure in high-risk neuroblastoma patients.

  9. Using droplet digital PCR to analyze MYCN and ALK copy number in plasma from patients with neuroblastoma

    PubMed Central

    Lodrini, Marco; Sprüssel, Annika; Astrahantseff, Kathy; Tiburtius, Daniela; Konschak, Robert; Lode, Holger N.; Fischer, Matthias; Keilholz, Ulrich; Eggert, Angelika; Deubzer, Hedwig E.

    2017-01-01

    The invasive nature of surgical biopsies deters sequential application, and single biopsies often fail to reflect tumor dynamics, intratumor heterogeneity and drug sensitivities likely to change during tumor evolution and treatment. Implementing molecular characterization of cell-free neuroblastoma-derived DNA isolated from blood plasma could improve disease assessment for treatment selection and monitoring of patients with high-risk neuroblastoma. We established droplet digital PCR (ddPCR) protocols for MYCN and ALK copy number status in plasma from neuroblastoma patients. Our ddPCR protocol accurately discriminated between MYCN and ALK amplification, gain and normal diploid status in a large panel of neuroblastoma cell lines, and discrepancies with reported MYCN and ALK status were detected, including a high-level MYCN amplification in NB-1, a MYCN gain in SH-SY5Y, a high-level ALK amplification in IMR-32 and ALK gains in BE(2)-C, Kelly, SH-SY5Y and LAN-6. MYCN and ALK status were also reliably determined from cell-free DNA derived from medium conditioned by the cell lines. MYCN and ALK copy numbers of subcutaneous neuroblastoma xenograft tumors were accurately determined from cell-free DNA in the mouse blood plasma. In a final validation step, we accurately distinguished MYCN and ALK copy numbers of the corresponding primary tumors using retrospectively collected blood plasma samples from 10 neuroblastoma patients. Our data justify the further development of molecular disease characterization using cell-free DNA in blood plasma from patients with neuroblastoma. This expanded molecular diagnostic palette may improve monitoring of disease progression including relapse and metastatic events as well as therapy success or failure in high-risk neuroblastoma patients. PMID:29156716

  10. Platelet factor XIIIa release during platelet aggregation and plasma clot strength measured by thrombelastography in patients with coronary artery disease treated with clopidogrel.

    PubMed

    Kreutz, Rolf P; Owens, Janelle; Lu, Deshun; Nystrom, Perry; Jin, Yan; Kreutz, Yvonne; Desta, Zeruesenay; Flockhart, David A

    2015-01-01

    It has been estimated that up to half of circulating factor XIIIa (FXIIIa) is stored in platelets. The release of FXIIIa from platelets upon stimulation with adenosine diphosphate (ADP) in patients with coronary artery disease treated with dual antiplatelet therapy has not been previously examined. Samples from 96 patients with established coronary artery disease treated with aspirin and clopidogrel were examined. Platelet aggregation was performed by light transmittance aggregometry in platelet-rich plasma (PRP), with platelet-poor plasma (PPP) as reference, and ADP 5 µM as agonist. Kaolin-activated thrombelastography (TEG) was performed in citrate PPP. PRP after aggregation was centrifuged and plasma supernatant (PSN) collected. FXIIIa was measured in PPP and PSN. Platelet aggregation after stimulation with ADP 5 µM resulted in 24% additional FXIIIa release in PSN as compared to PPP (99.3 ± 27 vs. 80.3 ± 24%, p < 0.0001). FXIIIa concentration in PSN correlated with maximal plasma clot strength (TEG-G) (r = 0.48, p < 0.0001), but not in PPP (r = 0.15, p = 0.14). Increasing quartiles of platelet-derived FXIIIa were associated with incrementally higher TEG-G (p = 0.012). FXIIIa release was similar between clopidogrel responders and non-responders (p = 0.18). In summary, platelets treated with aspirin and clopidogrel release a significant amount of FXIIIa upon aggregation by ADP. Platelet-derived FXIIIa may contribute to differences in plasma TEG-G, and thus, in part, provide a mechanistic explanation for high clot strength observed as a consequence of platelet activation. Variability in clopidogrel response does not significantly influence FXIIIa release from platelets.

  11. Blood safety--a focus on plasma derivatives in Mainland China.

    PubMed

    Zhu, Y M

    2007-01-01

    Plasma derivative production in Mainland China can be encapsulated by two figures: 50 years of history and 5000 tons of annually processed source plasma. Demands for albumin, immunoglobulinin and main clotting factors can barely be met, despite a relatively low average usage among China's population of 1.3 billion. The tragedy of contamination among plasma donors in Henan province in the early 1990's has left shadows on the safety of the plasma derivative industry. However, during the last ten years the Chinese government has made great strides forward. The regulation of the entire operation has been strengthened, from law and standard setting and upholding to stricter licensing regulations for plasma centers and fractionators. Public concerns in blood safety are gradually being relieved, and confidence is returning. Nevertheless, the plasma donors and hemophilia patients infected a decade ago by infected blood or plasma products represent a set of severe social and medical problems that the government and society must still deal with.

  12. Plasma α-synuclein and cognitive impairment in the Parkinson's Associated Risk Syndrome: A pilot study.

    PubMed

    Wang, Hua; Atik, Anzari; Stewart, Tessandra; Ginghina, Carmen; Aro, Patrick; Kerr, Kathleen F; Seibyl, John; Jennings, Danna; Jensen, Poul Henning; Marek, Kenneth; Shi, Min; Zhang, Jing

    2018-04-27

    Plasma total and nervous system derived exosomal (NDE) α-synuclein have been determined as potential biomarkers of Parkinson's disease (PD). To explore the utility of plasma α-synuclein in the prodromal phase of PD, plasma total and NDE α-synuclein were evaluated in baseline and 2-year follow-up samples from 256 individuals recruited as part of the Parkinson's Associated Risk Syndrome (PARS) study. The results demonstrated that baseline and longitudinal increases in total α-synuclein predicted progression of cognitive decline in hyposmic individuals with dopamine transporter (DAT) binding reduction. On the other hand, a longitudinal decrease in NDE α-synuclein predicted worsening cognitive scores in hyposmic individuals with DAT binding reduction. Finally, in individuals with faster DAT progression, decreasing NDE/total α-synuclein ratio was associated with a larger reduction in DAT from baseline to follow-up. These results suggest that, though underlying mechanisms remain to be defined, alterations in plasma total and NDE α-synuclein concentrations are likely associated with PD progression, especially in the aspect of cognitive impairment, at early stages of the disease. Copyright © 2018. Published by Elsevier Inc.

  13. Intracellular trafficking of the free cholesterol derived from LDL cholesteryl ester is defective in vivo in Niemann-Pick C disease: insights on normal metabolism of HDL and LDL gained from the NP-C mutation.

    PubMed

    Shamburek, R D; Pentchev, P G; Zech, L A; Blanchette-Mackie, J; Carstea, E D; VandenBroek, J M; Cooper, P S; Neufeld, E B; Phair, R D; Brewer, H B; Brady, R O; Schwartz, C C

    1997-12-01

    Niemann-Pick C disease (NP-C) is a rare inborn error of metabolism with hepatic involvement and neurological sequelae that usually manifest in childhood. Although in vitro studies have shown that the lysosomal distribution of LDL-derived cholesterol is defective in cultured cells of NP-C subjects, no unusual characteristics mark the plasma lipoprotein profiles. We set out to determine whether anomalies exist in vivo in the cellular distribution of newly synthesized, HDL-derived or LDL-derived cholesterol under physiologic conditions in NP-C subjects. Three affected and three normal male subjects were administered [14C]mevalonate as a tracer of newly synthesized cholesterol and [3H]cholesteryl linoleate in either HDL or LDL to trace the distribution of lipoprotein-derived free cholesterol. The rate of appearance of free [14C]- and free [3H]cholesterol in the plasma membrane was detected indirectly by monitoring their appearance in plasma and bile. The plasma disappearance of [3H]cholesteryl linoleate was slightly faster in NP-C subjects regardless of its lipoprotein origin. Appearance of free [14C] cholesterol ill the plasma (and in bile) was essentially identical in normal and affected individuals as was the initial appearance of free [3H]cholesterol derived from HDL, observed before extensive exchange occurred of the [3H]cholesteryl linoleate among lipoproteins. In contrast, the rate of appearance of LDL-derived free [3H]cholesterol in the plasma membrane of NP-C subjects, as detected in plasma and bile, was retarded to a similar extent that LDL cholesterol metabolism was defective in cultured fibroblasts of these affected subjects. These findings show that intracellular distribution of both newly synthesized and HDL-derived cholesterol are essentially unperturbed by the NP-C mutation, and therefore occur by lysosomal-independent paths. In contrast, in NP-C there is defective trafficking of LDL-derived cholesterol to the plasma membrane in vivo as well as in vitro. The in vivo assay of intracellular cholesterol distribution developed herein should prove useful to quickly evaluate therapeutic interventions for NP-C.

  14. Feasibility of Juno radio occultations of the Io plasma torus

    NASA Astrophysics Data System (ADS)

    Phipps, P. H.; Withers, P.

    2016-12-01

    Jupiter's magnetosphere is driven by internally produced plasma. The innermost Galilean satellite, Io, isthe dominant source of this plasma. Volcanoes on Io's surface create an atmosphere of sulfur and oxygenwhich escapes into Jupiter's magnetosphere and becomes ionized. This ionized material is trapped byJupiter's magnetic field and creates a torus of plasma centered at Io's orbital radius, called the Io plasmatorus. This torus is divided into three regions distinct in both density and composition. Densities in thistorus can be probed by spacecraft via radio occultations. A radio occultation occurs when plasma comesbetween a spacecraft and a receiver during a time when the spacecraft is sending a radio signal. The Junospacecraft, which arrived in orbit around Jupiter in July 2016, is in an orbit which will be ideal forperforming radio occultations of the Io plasma torus. We test the feasibility of using thetelecommunications system on the Juno spacecraft to perform a radio occultation. Io plasma torusdensities derived from Voyager 1 data are used in creating a model torus. Using the Ka and X-band radiofrequencies we derive vertical profiles for the total electron content of the modeled Io plasma torus. AMarkov Chain Monte Carlo fit is performed on the derived profiles to extract, for each of the torusregions, the scale height and peak total electron content. The scale height can be used to derive atemperature for the torus while the peak total electron content can be used to derive the peak electrondensity. We show that Juno radio occultation measurements of the Io plasma torus are feasible andscientifically valuable.

  15. Surface processing and ageing behavior of silk fabrics treated with atmospheric-pressure plasma for pigment-based ink-jet printing

    NASA Astrophysics Data System (ADS)

    Zhang, Chunming; Wang, Libing; Yu, Miao; Qu, Lijun; Men, Yajing; Zhang, Xiangwu

    2018-03-01

    Pigment inkjet printing has highlighted the advantages of cost-effective, short production cycle and environment-friendly. However, patterns directly printed with pigment inks usually have low color yields and blurry images which are caused by bleeding phenomenon. This work presents an atmospheric-pressure plasma method for improving the pigment-based ink-jet printing performance of silk fabrics. The effects of surface changes induced are discussed, with data derived from morphological study by atomic force microscopy (AFM), chemical analysis using X-ray photoelectron spectroscopy (XPS) and contact angle measurement. Ink-jet printing experiments were conducted to study the influence of measured changes on anti-bleeding property and color strength of treated and original samples. The ageing experiment indicates that the modified silk fabrics should be printed within 24 h after plasma processing for maximum color yields. This study explores an effective approach for the atmospheric-pressure plasma, which can provide its significant use in improving the surface properties and ink-jet printing performance of fabrics.

  16. Plasma Dispersion Function for the Kappa Distribution

    NASA Technical Reports Server (NTRS)

    Podesta, John J.

    2004-01-01

    The plasma dispersion function is computed for a homogeneous isotropic plasma in which the particle velocities are distributed according to a Kappa distribution. An ordinary differential equation is derived for the plasma dispersion function and it is shown that the solution can be written in terms of Gauss' hypergeometric function. Using the extensive theory of the hypergeometric function, various mathematical properties of the plasma dispersion function are derived including symmetry relations, series expansions, integral representations, and closed form expressions for integer and half-integer values of K.

  17. Prior exercise alters the difference between arterialised and venous glycaemia: implications for blood sampling procedures.

    PubMed

    Edinburgh, Robert M; Hengist, Aaron; Smith, Harry A; Betts, James A; Thompson, Dylan; Walhin, Jean-Philippe; Gonzalez, Javier T

    2017-05-01

    Oral glucose tolerance and insulin sensitivity are common measures, but are determined using various blood sampling methods, employed under many different experimental conditions. This study established whether measures of oral glucose tolerance and oral glucose-derived insulin sensitivity (insulin sensitivity indices; ISI) differ when calculated from venous v. arterialised blood. Critically, we also established whether any differences between sampling methods are consistent across distinct metabolic conditions (after rest v. after exercise). A total of ten healthy men completed two trials in a randomised order, each consisting of a 120-min oral glucose tolerance test (OGTT), either at rest or post-exercise. Blood was sampled simultaneously from a heated hand (arterialised) and an antecubital vein of the contralateral arm (venous). Under both conditions, glucose time-averaged AUC was greater from arterialised compared with venous plasma but importantly, this difference was larger after rest relative to after exercise (0·99 (sd 0·46) v. 0·56 (sd 0·24) mmol/l, respectively; P<0·01). OGTT-derived ISIMatsuda and ISICederholm were lower when calculated from arterialised relative to venous plasma and the arterialised-venous difference was greater after rest v. after exercise (ISIMatsuda: 1·97 (sd 0·81) v. 1·35 (sd 0·57) arbitrary units (au), respectively; ISICederholm : 14·76 (sd 7·83) v. 8·70 (sd 3·95) au, respectively; both P<0·01). Venous blood provides lower postprandial glucose concentrations and higher estimates of insulin sensitivity, compared with arterialised blood. Most importantly, these differences between blood sampling methods are not consistent after rest v. post-exercise, preventing standardised venous-to-arterialised corrections from being readily applied.

  18. Comparative Studies of the Proteome, Glycoproteome, and N-Glycome of Clear Cell Renal Cell Carcinoma Plasma before and after Curative Nephrectomy

    PubMed Central

    2015-01-01

    Clear cell renal cell carcinoma is the most prevalent of all reported kidney cancer cases, and currently there are no markers for early diagnosis. This has stimulated great research interest recently because early detection of the disease can significantly improve the low survival rate. Combining the proteome, glycoproteome, and N-glycome data from clear cell renal cell carcinoma plasma has the potential of identifying candidate markers for early diagnosis and prognosis and/or to monitor disease recurrence. Here, we report on the utilization of a multi-dimensional fractionation approach (12P-M-LAC) and LC–MS/MS to comprehensively investigate clear cell renal cell carcinoma plasma collected before (disease) and after (non-disease) curative nephrectomy (n = 40). Proteins detected in the subproteomes were investigated via label-free quantification. Protein abundance analysis revealed a number of low-level proteins with significant differential expression levels in disease samples, including HSPG2, CD146, ECM1, SELL, SYNE1, and VCAM1. Importantly, we observed a strong correlation between differentially expressed proteins and clinical status of the patient. Investigation of the glycoproteome returned 13 candidate glycoproteins with significant differential M-LAC column binding. Qualitative analysis indicated that 62% of selected candidate glycoproteins showed higher levels (upregulation) in M-LAC bound fraction of disease samples. This observation was further confirmed by released N-glycans data in which 53% of identified N-glycans were present at different levels in plasma in the disease vs non-disease samples. This striking result demonstrates the potential for significant protein glycosylation alterations in clear cell renal cell carcinoma cancer plasma. With future validation in a larger cohort, information derived from this study may lead to the development of clear cell renal cell carcinoma candidate biomarkers. PMID:25184692

  19. Finite grid radius and thickness effects on retarding potential analyzer measured suprathermal electron density and temperature

    NASA Technical Reports Server (NTRS)

    Knudsen, William C.

    1992-01-01

    The effect of finite grid radius and thickness on the electron current measured by planar retarding potential analyzers (RPAs) is analyzed numerically. Depending on the plasma environment, the current is significantly reduced below that which is calculated using a theoretical equation derived for an idealized RPA having grids with infinite radius and vanishingly small thickness. A correction factor to the idealized theoretical equation is derived for the Pioneer Venus (PV) orbiter RPA (ORPA) for electron gasses consisting of one or more components obeying Maxwell statistics. The error in density and temperature of Maxwellian electron distributions previously derived from ORPA data using the theoretical expression for the idealized ORPA is evaluated by comparing the densities and temperatures derived from a sample of PV ORPA data using the theoretical expression with and without the correction factor.

  20. Influence of dialysis modality on plasma and tissue concentrations of pentosidine in patients with end-stage renal disease.

    PubMed

    Friedlander, M A; Wu, Y C; Schulak, J A; Monnier, V M; Hricik, D E

    1995-03-01

    Plasma and tissue concentrations of pentose-derived glycation end-products ("pentosidine") are elevated in diabetic patients with normal renal function and in both diabetic and nondiabetic patients with end-stage renal disease. To determine the influence of dialysis modality and other clinical variables on the accumulation of pentosidine, we used high-performance liquid chromatography to measure this advanced glycation end-product in plasma, skin, and peritoneal samples obtained from 65 hemodialysis and 45 peritoneal dialysis patients. Plasma pentosidine levels were significantly lower in peritoneal dialysis patients. Concentrations of pentosidine in skin were similar in the two groups. In contrast, peritoneal concentrations of pentosidine were significantly higher in the patients maintained on peritoneal dialysis. Our results demonstrate that dialysis modality influences the plasma and tissue distribution of pentosidine. Compared with hemodialysis, peritoneal dialysis is associated with lower levels of this glycation end-product in plasma, but with higher levels in the peritoneum. The mechanisms accounting for lower circulating levels of pentosidine in peritoneal dialysis patients remain to be determined. Higher levels in peritoneal tissues may reflect chronic exposure to the high concentrations of glucose in peritoneal dialysate.

  1. Clinical correlates of plasma brain-derived neurotrophic factor in post-traumatic stress disorder spectrum after a natural disaster.

    PubMed

    Stratta, Paolo; Sanità, Patrizia; Bonanni, Roberto L; de Cataldo, Stefano; Angelucci, Adriano; Rossi, Rodolfo; Origlia, Nicola; Domenici, Luciano; Carmassi, Claudia; Piccinni, Armando; Dell'Osso, Liliana; Rossi, Alessandro

    2016-10-30

    Clinical correlates of plasma Brain-Derived Neurotrophic Factor (BDNF) have been investigated in a clinical population with Post Traumatic Stress Disorder (PTSD) symptoms and healthy control subjects who survived to the L'Aquila 2009 earthquake. Twenty-six outpatients and 14 control subjects were recruited. Assessments included: Structured Clinical Interview for DSM-IV Axis-I disorders Patient Version, Trauma and Loss Spectrum-Self Report (TALS-SR) for post-traumatic spectrum symptoms. Thirteen patients were diagnosed as Full PTSD and 13 as Partial PTSD. The subjects with full-blown PTSD showed lower BDNF level than subjects with partial PTSD and controls. Different relationship patterns of BDNF with post-traumatic stress spectrum symptoms have been reported in the three samples. Our findings add more insight on the mechanisms regulating BDNF levels in response to stress and further proofs of the utility of the distinction of PTSD into full and partial categories. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  2. Bernstein-Greene-Kruskal theory of electron holes in superthermal space plasma

    NASA Astrophysics Data System (ADS)

    Aravindakshan, Harikrishnan; Kakad, Amar; Kakad, Bharati

    2018-05-01

    Several spacecraft missions have observed electron holes (EHs) in Earth's and other planetary magnetospheres. These EHs are modeled with the stationary solutions of Vlasov-Poisson equations, obtained by adopting the Bernstein-Greene-Kruskal (BGK) approach. Through the literature survey, we find that the BGK EHs are modelled by using either thermal distribution function or any statistical distribution derived from particular spacecraft observations. However, Maxwell distributions are quite rare in space plasmas; instead, most of these plasmas are superthermal in nature and generally described by kappa distribution. We have developed a one-dimensional BGK model of EHs for space plasma that follows superthermal kappa distribution. The analytical solution of trapped electron distribution function for such plasmas is derived. The trapped particle distribution function in plasma following kappa distribution is found to be steeper and denser as compared to that for Maxwellian distribution. The width-amplitude relation of perturbation for superthermal plasma is derived and allowed regions of stable BGK solutions are obtained. We find that the stable BGK solutions are better supported by superthermal plasmas compared to that of thermal plasmas for small amplitude perturbations.

  3. Optimization of quantitative proteomic analysis of clots generated from plasma of patients with venous thromboembolism.

    PubMed

    Stachowicz, Aneta; Siudut, Jakub; Suski, Maciej; Olszanecki, Rafał; Korbut, Ryszard; Undas, Anetta; Wiśniewski, Jacek R

    2017-01-01

    It is well known that fibrin network binds a large variety of proteins, including inhibitors and activators of fibrinolysis, which may affect clot properties, such as stability and susceptibility to fibrinolysis. Specific plasma clot composition differs between individuals and may change in disease states. However, the plasma clot proteome has not yet been in-depth analyzed, mainly due to technical difficulty related to the presence of a highly abundant protein-fibrinogen and fibrin that forms a plasma clot. The aim of our study was to optimize quantitative proteomic analysis of fibrin clots prepared ex vivo from citrated plasma of the peripheral blood drawn from patients with prior venous thromboembolism (VTE). We used a multiple enzyme digestion filter aided sample preparation, a multienzyme digestion (MED) FASP method combined with LC-MS/MS analysis performed on a Proxeon Easy-nLC System coupled to the Q Exactive HF mass spectrometer. We also evaluated the impact of peptide fractionation with pipet-tip strong anion exchange (SAX) method on the obtained results. Our proteomic approach revealed 476 proteins repeatedly identified in the plasma fibrin clots from patients with VTE including extracellular vesicle-derived proteins, lipoproteins, fibrinolysis inhibitors, and proteins involved in immune responses. The MED FASP method using three different enzymes: LysC, trypsin and chymotrypsin increased the number of identified peptides and proteins and their sequence coverage as compared to a single step digestion. Peptide fractionation with a pipet-tip strong anion exchange (SAX) protocol increased the depth of proteomic analyses, but also extended the time needed for sample analysis with LC-MS/MS. The MED FASP method combined with a label-free quantification is an excellent proteomic approach for the analysis of fibrin clots prepared ex vivo from citrated plasma of patients with prior VTE.

  4. Red blood cell-derived microparticles isolated from blood units initiate and propagate thrombin generation.

    PubMed

    Rubin, Olivier; Delobel, Julien; Prudent, Michel; Lion, Niels; Kohl, Kid; Tucker, Erik I; Tissot, Jean-Daniel; Angelillo-Scherrer, Anne

    2013-08-01

    Red blood cell-derived microparticles (RMPs) are small phospholipid vesicles shed from RBCs in blood units, where they accumulate during storage. Because microparticles are bioactive, it could be suggested that RMPs are mediators of posttransfusion complications or, on the contrary, constitute a potential hemostatic agent. This study was performed to establish the impact on coagulation of RMPs isolated from blood units. Using calibrated automated thrombography, we investigated whether RMPs affect thrombin generation (TG) in plasma. We found that RMPs were not only able to increase TG in plasma in the presence of a low exogenous tissue factor (TF) concentration, but also to initiate TG in plasma in absence of exogenous TF. TG induced by RMPs in the absence of exogenous TF was neither affected by the presence of blocking anti-TF nor by the absence of Factor (F)VII. It was significantly reduced in plasma deficient in FVIII or F IX and abolished in FII-, FV-, FX-, or FXI-deficient plasma. TG was also totally abolished when anti-XI 01A6 was added in the sample. Finally, neither Western blotting, flow cytometry, nor immunogold labeling allowed the detection of traces of TF antigen. In addition, RMPs did not comprise polyphosphate, an important modulator of coagulation. Taken together, our data show that RMPs have FXI-dependent procoagulant properties and are able to initiate and propagate TG. The anionic surface of RMPs might be the site of FXI-mediated TG amplification and intrinsic tenase and prothrombinase complex assembly. © 2012 American Association of Blood Banks.

  5. Brain-Derived Neurotrophic Factor in Patients with Huntington's Disease

    PubMed Central

    Zuccato, Chiara; Mariotti, Caterina; Valenza, Marta; Lahiri, Nayana; Wild, Edward J.; Sassone, Jenny; Ciammola, Andrea; Bachoud-Lèvi, Anne Catherine; Tabrizi, Sarah J.; Di Donato, Stefano; Cattaneo, Elena

    2011-01-01

    Reduced Brain-Derived Neurotrophic Factor (BDNF) levels have been described in a number of patho-physiological conditions, most notably, in Huntington's disease (HD), a progressive neurodegenerative disorder. Since BDNF is also produced in blood, we have undertaken the measurement of its peripheral levels in the attempt to identify a possible link with HD prognosis and/or its progression. Here we evaluated BDNF level in 398 blood samples including 138 controls, 56 preHD, and 204 HD subjects. We found that BDNF protein levels were not reliably different between groups, whether measured in plasma (52 controls, 26 preHD, 105 HD) or serum (39 controls, 5 preHD, 29 HD). Our experience, and a re-analysis of the literature highlighted that intra-group variability and methodological aspects affect this measurement, especially in serum. We also assessed BDNF mRNA levels in blood samples from 47 controls, 25 preHD, and 70 HD subjects, and found no differences among the groups. We concluded that levels of BDNF in human blood were not informative (mRNA levels or plasma protein level) nor reliable (serum protein levels) as HD biomarkers. We also wish to warn the scientific community in interpreting the significance of changes measured in BDNF protein levels in serum from patients suffering from different conditions. PMID:21857974

  6. Simultaneous determination of phosphatidylcholine-derived quaternary ammonium compounds by a LC-MS/MS method in human blood plasma, serum and urine samples.

    PubMed

    Steuer, Christian; Schütz, Philipp; Bernasconi, Luca; Huber, Andreas R

    2016-01-01

    The determination of circulating trimethylamine-N-oxide (TMAO), choline, betaine, l-carnitine and O-acetyl-l-carnitine concentration in different human matrices is of great clinical interest. Recent results highlighted the prognostic value of TMAO and quaternary ammonium containing metabolites in the field of cardiovascular and kidney diseases. Herein, we report a method for the rapid and simultaneous measurement of closely related phosphatidylcholine-derived metabolites in three different biological matrices by stable isotope dilution assay. Plasma, serum and urine samples were simply deproteinized and separated by HILIC-chromatography. Detection and quantification were performed using LC-MS/MS with electrospray ionization in positive mode. For accuracy and precision, full calibration was performed covering more than the full reference range. Assay performance metrics include intra- and interday imprecision were below 10% for all analytes. To exclude matrix effects standard addition methods were applied for all matrices. It was shown that calibration standards and quality control prepared in water can be used instead of matrix-matched calibration and controls. The LC/MS/MS-based assay described in this article may improve future clinical studies evaluating TMAO and related substances as prognostic markers for cardiovascular risk and all-cause mortality in different patient populations. Copyright © 2015 Elsevier B.V. All rights reserved.

  7. Nitro-fatty acid metabolome: saturation, desaturation, beta-oxidation, and protein adduction.

    PubMed

    Rudolph, Volker; Schopfer, Francisco J; Khoo, Nicholas K H; Rudolph, Tanja K; Cole, Marsha P; Woodcock, Steven R; Bonacci, Gustavo; Groeger, Alison L; Golin-Bisello, Franca; Chen, Chen-Shan; Baker, Paul R S; Freeman, Bruce A

    2009-01-16

    Nitrated derivatives of fatty acids (NO2-FA) are pluripotent cell-signaling mediators that display anti-inflammatory properties. Current understanding of NO2-FA signal transduction lacks insight into how or if NO2-FA are modified or metabolized upon formation or administration in vivo. Here the disposition and metabolism of nitro-9-cis-octadecenoic (18:1-NO2) acid was investigated in plasma and liver after intravenous injection in mice. High performance liquid chromatography-tandem mass spectrometry analysis showed that no 18:1-NO2 or metabolites were detected under basal conditions, whereas administered 18:1-NO2 is rapidly adducted to plasma thiol-containing proteins and glutathione. NO2-FA are also metabolized via beta-oxidation, with high performance liquid chromatography-tandem mass spectrometry analysis of liver lipid extracts of treated mice revealing nitro-7-cis-hexadecenoic acid, nitro-5-cis-tetradecenoic acid, and nitro-3-cis-dodecenoic acid and corresponding coenzyme A derivatives of 18:1-NO2 as metabolites. Additionally, a significant proportion of 18:1-NO2 and its metabolites are converted to nitroalkane derivatives by saturation of the double bond, and to a lesser extent are desaturated to diene derivatives. There was no evidence of the formation of nitrohydroxyl or conjugated ketone derivatives in organs of interest, metabolites expected upon 18:1-NO2 hydration or nitric oxide (*NO) release. Plasma samples from treated mice had significant extents of protein-adducted 18:1-NO2 detected by exchange to added beta-mercaptoethanol. This, coupled with the observation of 18:1-NO2 release from glutathione-18:1-NO2 adducts, supports that reversible and exchangeable NO2-FA-thiol adducts occur under biological conditions. After administration of [3H]18:1-NO2, 64% of net radiolabel was recovered 90 min later in plasma (0.2%), liver (18%), kidney (2%), adipose tissue (2%), muscle (31%), urine (6%), and other tissue compartments, and may include metabolites not yet identified. In aggregate, these findings show that electrophilic FA nitroalkene derivatives (a) acquire an extended half-life by undergoing reversible and exchangeable electrophilic reactions with nucleophilic targets and (b) are metabolized predominantly via saturation of the double bond and beta-oxidation reactions that terminate at the site of acyl-chain nitration.

  8. Nitro-fatty Acid Metabolome: Saturation, Desaturation, β-Oxidation, and Protein Adduction*

    PubMed Central

    Rudolph, Volker; Schopfer, Francisco J.; Khoo, Nicholas K. H.; Rudolph, Tanja K.; Cole, Marsha P.; Woodcock, Steven R.; Bonacci, Gustavo; Groeger, Alison L.; Golin-Bisello, Franca; Chen, Chen-Shan; Baker, Paul R. S.; Freeman, Bruce A.

    2009-01-01

    Nitrated derivatives of fatty acids (NO2-FA) are pluripotent cell-signaling mediators that display anti-inflammatory properties. Current understanding of NO2-FA signal transduction lacks insight into how or if NO2-FA are modified or metabolized upon formation or administration in vivo. Here the disposition and metabolism of nitro-9-cis-octadecenoic (18:1-NO2) acid was investigated in plasma and liver after intravenous injection in mice. High performance liquid chromatography-tandem mass spectrometry analysis showed that no 18:1-NO2 or metabolites were detected under basal conditions, whereas administered 18:1-NO2 is rapidly adducted to plasma thiol-containing proteins and glutathione. NO2-FA are also metabolized via β-oxidation, with high performance liquid chromatography-tandem mass spectrometry analysis of liver lipid extracts of treated mice revealing nitro-7-cis-hexadecenoic acid, nitro-5-cis-tetradecenoic acid, and nitro-3-cis-dodecenoic acid and corresponding coenzyme A derivatives of 18:1-NO2 as metabolites. Additionally, a significant proportion of 18:1-NO2 and its metabolites are converted to nitroalkane derivatives by saturation of the double bond, and to a lesser extent are desaturated to diene derivatives. There was no evidence of the formation of nitrohydroxyl or conjugated ketone derivatives in organs of interest, metabolites expected upon 18:1-NO2 hydration or nitric oxide (•NO) release. Plasma samples from treated mice had significant extents of protein-adducted 18:1-NO2 detected by exchange to added β-mercaptoethanol. This, coupled with the observation of 18:1-NO2 release from glutathione-18:1-NO2 adducts, supports that reversible and exchangeable NO2-FA-thiol adducts occur under biological conditions. After administration of [3H]18:1-NO2, 64% of net radiolabel was recovered 90 min later in plasma (0.2%), liver (18%), kidney (2%), adipose tissue (2%), muscle (31%), urine (6%), and other tissue compartments, and may include metabolites not yet identified. In aggregate, these findings show that electrophilic FA nitroalkene derivatives (a) acquire an extended half-life by undergoing reversible and exchangeable electrophilic reactions with nucleophilic targets and (b) are metabolized predominantly via saturation of the double bond and β-oxidation reactions that terminate at the site of acyl-chain nitration. PMID:19015269

  9. Economical impact of plasma fractionation project in Iran on affordability of plasma-derived medicines.

    PubMed

    Cheraghali, A M; Aboofazeli, R

    2009-12-01

    In Iran all transfusion services are concentrated under authority of one public and centralized transfusion organization which has created the opportunity of using plasma produced in its blood centers for fractionation. In 2008 voluntary and non remunerated Iranian donors donated 1.8 million units of blood. This indicates a 25/1000 donation index. After responding to the needs for fresh plasma and cryoprecipitate each year about 150000 L of recovered plasma are reserved for fractionation. In an attempt to improve both blood safety profile and availability and affordability of plasma derived medicines, Iran's national transfusion service has entered into a contract fractionation agreement for surplus of plasma produced from donated blood by voluntary non remunerated donors. In order to ensure safety of product produced, Iran has chosen to collaborate with international fractionators based in highly regulated countries. The main objective of this study was to evaluate the impact of contract plasma fractionation on the affordability of the plasma derived medicines in Iran. During 2006-2008, Iran's contract fractionation project was able to produce 46%, 18% and 6% of IVIG, Albumin and FVIII consumed in Iran's market, respectively. In contrary to IVIG and Albumin, due to fairly high consumption of FVIII in Iran, the role of fractionation project in meeting the needs to FVIII was not substantial. However, Iran's experience has shown that contract plasma fractionation, through direct and indirect effects on price of plasma derived medicines, could substantially improve availability and affordability of such products in national health care system.

  10. A validated inductively coupled plasma mass spectrometry (ICP-MS) method for the quantification of total platinum content in plasma, plasma ultrafiltrate, urine and peritoneal fluid.

    PubMed

    Lemoine, Lieselotte; Thijssen, Elsy; Noben, Jean-Paul; Adriaensens, Peter; Carleer, Robert; Speeten, Kurt Van der

    2018-04-15

    Oxaliplatin is a platinum (Pt) 1 containing antineoplastic agent that is applied in current clinical practice for the treatment of colon and appendiceal neoplasms. A fully validated, highly sensitive, high throughput inductively coupled plasma mass spectrometry (ICP-MS) method is provided to quantify the total Pt content in plasma, plasma ultrafiltrate, urine and peritoneal fluid. In this ICP-MS approach, the only step of sample preparation is a 1000-fold dilution in 0.5% nitric acid, allowing the analysis of 17 samples per hour. Detection of Pt was achieved over a linear range of 0.01-100 ng/mL. The limit of quantification was 18.0 ng/mL Pt in plasma, 8.0 ng/mL in ultrafiltrate and 6.1 ng/mL in urine and peritoneal fluid. The ICP-MS method was further validated for inter-and intraday precision and accuracy (≤15%), recovery, robustness and stability. Short-term storage of the biofluids, for 14 days, can be performed at -4 °C, -24 °C and -80 °C. As to long-term stability, up to 5 months, storage at -80 °C is encouraged. Furthermore, a timeline assessing the total and unbound Pt fraction in plasma and ultrafiltrate over a period of 45 h is provided. Following an incubation period of 5 h at 37 °C, 19-21% of Pt was recovered in the ultrafiltrate, emphasizing the extensive and rapid binding of oxaliplatin-derived Pt to plasma proteins. The described method can easily be implemented in a routine setting for pharmacokinetic studies in patients treated with oxaliplatin-based hyperthermic intraperitoneal perioperative chemotherapy. Copyright © 2018 Elsevier B.V. All rights reserved.

  11. Intestinal Microbiota-Derived Metabolomic Blood Plasma Markers for Prior Radiation Injury

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ó Broin, Pilib; Department of Mathematical Sciences, Yeshiva University, New York, New York; Vaitheesvaran, Bhavapriya

    2015-02-01

    Purpose: Assessing whole-body radiation injury and absorbed dose is essential for remediation efforts following accidental or deliberate exposure in medical, industrial, military, or terrorist incidents. We hypothesize that variations in specific metabolite concentrations extracted from blood plasma would correlate with whole-body radiation injury and dose. Methods and Materials: Groups of C57BL/6 mice (n=12 per group) were exposed to 0, 2, 4, 8, and 10.4 Gy of whole-body gamma radiation. At 24 hours after treatment, all animals were euthanized, and both plasma and liver biopsy samples were obtained, the latter being used to identify a distinct hepatic radiation injury response within plasma. A semiquantitative,more » untargeted metabolite/lipid profile was developed using gas chromatography-mass spectrometry and liquid chromatography-tandem mass spectrometry, which identified 354 biochemical compounds. A second set of C57BL/6 mice (n=6 per group) were used to assess a subset of identified plasma markers beyond 24 hours. Results: We identified a cohort of 37 biochemical compounds in plasma that yielded the optimal separation of the irradiated sample groups, with the most correlated metabolites associated with pyrimidine (positively correlated) and tryptophan (negatively correlated) metabolism. The latter were predominantly associated with indole compounds, and there was evidence that these were also correlated between liver and plasma. No evidence of saturation as a function of dose was observed, as has been noted for studies involving metabolite analysis of urine. Conclusions: Plasma profiling of specific metabolites related to pyrimidine and tryptophan pathways can be used to differentiate whole-body radiation injury and dose response. As the tryptophan-associated indole compounds have their origin in the intestinal microbiome and subsequently the liver, these metabolites particularly represent an attractive marker for radiation injury within blood plasma.« less

  12. Time-nonlocal kinetic equations, jerk and hyperjerk in plasmas and solar physics

    NASA Astrophysics Data System (ADS)

    El-Nabulsi, Rami Ahmad

    2018-06-01

    The simulation and analysis of nonlocal effects in fluids and plasmas is an inherently complicated problem due to the massive breadth of physics required to describe the nonlocal dynamics. This is a multi-physics problem that draws upon various miscellaneous fields, such as electromagnetism and statistical mechanics. In this paper we strive to focus on one narrow but motivating mathematical way: the derivation of nonlocal plasma-fluid equations from a generalized nonlocal Liouville derivative operator motivated from Suykens's nonlocal arguments. The paper aims to provide a guideline toward modeling nonlocal effects occurring in plasma-fluid systems by means of a generalized nonlocal Boltzmann equation. The generalized nonlocal equations of fluid dynamics are derived and their implications in plasma-fluid systems are addressed, discussed and analyzed. Three main topics were discussed: Landau damping in plasma electrodynamics, ideal MHD and solar wind. A number of features were revealed, analyzed and confronted with recent research results and observations.

  13. Systematic Evaluation of the Use of Human Plasma and Serum for Mass-Spectrometry-Based Shotgun Proteomics.

    PubMed

    Lan, Jiayi; Núñez Galindo, Antonio; Doecke, James; Fowler, Christopher; Martins, Ralph N; Rainey-Smith, Stephanie R; Cominetti, Ornella; Dayon, Loïc

    2018-04-06

    Over the last two decades, EDTA-plasma has been used as the preferred sample matrix for human blood proteomic profiling. Serum has also been employed widely. Only a few studies have assessed the difference and relevance of the proteome profiles obtained from plasma samples, such as EDTA-plasma or lithium-heparin-plasma, and serum. A more complete evaluation of the use of EDTA-plasma, heparin-plasma, and serum would greatly expand the comprehensiveness of shotgun proteomics of blood samples. In this study, we evaluated the use of heparin-plasma with respect to EDTA-plasma and serum to profile blood proteomes using a scalable automated proteomic pipeline (ASAP 2 ). The use of plasma and serum for mass-spectrometry-based shotgun proteomics was first tested with commercial pooled samples. The proteome coverage consistency and the quantitative performance were compared. Furthermore, protein measurements in EDTA-plasma and heparin-plasma samples were comparatively studied using matched sample pairs from 20 individuals from the Australian Imaging, Biomarkers and Lifestyle (AIBL) Study. We identified 442 proteins in common between EDTA-plasma and heparin-plasma samples. Overall agreement of the relative protein quantification between the sample pairs demonstrated that shotgun proteomics using workflows such as the ASAP 2 is suitable in analyzing heparin-plasma and that such sample type may be considered in large-scale clinical research studies. Moreover, the partial proteome coverage overlaps (e.g., ∼70%) showed that measures from heparin-plasma could be complementary to those obtained from EDTA-plasma.

  14. Analysis of Phenolic Compounds and Antioxidant Activity in Wild Blackberry Fruits

    PubMed Central

    Oszmiański, Jan; Nowicka, Paulina; Teleszko, Mirosława; Wojdyło, Aneta; Cebulak, Tomasz; Oklejewicz, Krzysztof

    2015-01-01

    Twenty three different wild blackberry fruit samples were assessed regarding their phenolic profiles and contents (by LC/MS quadrupole time-of-flight (QTOF) and antioxidant activity (ferric reducing ability of plasma (FRAP) and 2,2-azinobis (3-ethyl-benzothiazoline-6-sulfonic acid) (ABTS)) by two different extraction methods. Thirty four phenolic compounds were detected (8 anthocyanins, 15 flavonols, 3 hydroxycinnamic acids, 6 ellagic acid derivatives and 2 flavones). In samples, where pressurized liquid extraction (PLE) was used for extraction, a greater increase in yields of phenolic compounds was observed, especially in ellagic acid derivatives (max. 59%), flavonols (max. 44%) and anthocyanins (max. 29%), than after extraction by the ultrasonic technique extraction (UAE) method. The content of phenolic compounds was significantly correlated with the antioxidant activity of the analyzed samples. Principal component analysis (PCA) revealed that the PLE method was more suitable for the quantitative extraction of flavonols, while the UAE method was for hydroxycinnamic acids. PMID:26132562

  15. Large-Scale Interlaboratory Study to Develop, Analytically Validate and Apply Highly Multiplexed, Quantitative Peptide Assays to Measure Cancer-Relevant Proteins in Plasma*

    PubMed Central

    Abbatiello, Susan E.; Schilling, Birgit; Mani, D. R.; Zimmerman, Lisa J.; Hall, Steven C.; MacLean, Brendan; Albertolle, Matthew; Allen, Simon; Burgess, Michael; Cusack, Michael P.; Gosh, Mousumi; Hedrick, Victoria; Held, Jason M.; Inerowicz, H. Dorota; Jackson, Angela; Keshishian, Hasmik; Kinsinger, Christopher R.; Lyssand, John; Makowski, Lee; Mesri, Mehdi; Rodriguez, Henry; Rudnick, Paul; Sadowski, Pawel; Sedransk, Nell; Shaddox, Kent; Skates, Stephen J.; Kuhn, Eric; Smith, Derek; Whiteaker, Jeffery R.; Whitwell, Corbin; Zhang, Shucha; Borchers, Christoph H.; Fisher, Susan J.; Gibson, Bradford W.; Liebler, Daniel C.; MacCoss, Michael J.; Neubert, Thomas A.; Paulovich, Amanda G.; Regnier, Fred E.; Tempst, Paul; Carr, Steven A.

    2015-01-01

    There is an increasing need in biology and clinical medicine to robustly and reliably measure tens to hundreds of peptides and proteins in clinical and biological samples with high sensitivity, specificity, reproducibility, and repeatability. Previously, we demonstrated that LC-MRM-MS with isotope dilution has suitable performance for quantitative measurements of small numbers of relatively abundant proteins in human plasma and that the resulting assays can be transferred across laboratories while maintaining high reproducibility and quantitative precision. Here, we significantly extend that earlier work, demonstrating that 11 laboratories using 14 LC-MS systems can develop, determine analytical figures of merit, and apply highly multiplexed MRM-MS assays targeting 125 peptides derived from 27 cancer-relevant proteins and seven control proteins to precisely and reproducibly measure the analytes in human plasma. To ensure consistent generation of high quality data, we incorporated a system suitability protocol (SSP) into our experimental design. The SSP enabled real-time monitoring of LC-MRM-MS performance during assay development and implementation, facilitating early detection and correction of chromatographic and instrumental problems. Low to subnanogram/ml sensitivity for proteins in plasma was achieved by one-step immunoaffinity depletion of 14 abundant plasma proteins prior to analysis. Median intra- and interlaboratory reproducibility was <20%, sufficient for most biological studies and candidate protein biomarker verification. Digestion recovery of peptides was assessed and quantitative accuracy improved using heavy-isotope-labeled versions of the proteins as internal standards. Using the highly multiplexed assay, participating laboratories were able to precisely and reproducibly determine the levels of a series of analytes in blinded samples used to simulate an interlaboratory clinical study of patient samples. Our study further establishes that LC-MRM-MS using stable isotope dilution, with appropriate attention to analytical validation and appropriate quality control measures, enables sensitive, specific, reproducible, and quantitative measurements of proteins and peptides in complex biological matrices such as plasma. PMID:25693799

  16. Prostate Cancer Pathology Resource Network

    DTIC Science & Technology

    2012-07-01

    microarrays (TMAs), serum, plasma , buffy coat, prostatic fluid, and derived specimens (DNA and RNA); these specimens are linked to clinical and...research community. The specimens in the PCBN include tissues from prostatectomies, serum, plasma , buffy coat, prostatic fluid, derived specimens such...prostatectomy, seminal vesicles), body fluids (serum, plasma , buffy coat, prostatic fluid; most can be matched to tumor and benign tissue), and

  17. Standard operating procedures for pre-analytical handling of blood and urine for metabolomic studies and biobanks.

    PubMed

    Bernini, Patrizia; Bertini, Ivano; Luchinat, Claudio; Nincheri, Paola; Staderini, Samuele; Turano, Paola

    2011-04-01

    (1)H NMR metabolic profiling of urine, serum and plasma has been used to monitor the impact of the pre-analytical steps on the sample quality and stability in order to propose standard operating procedures (SOPs) for deposition in biobanks. We analyzed the quality of serum and plasma samples as a function of the elapsed time (t = 0-4 h) between blood collection and processing and of the time from processing to freezing (up to 24 h). The stability of the urine metabolic profile over time (up to 24 h) at various storage temperatures was monitored as a function of the different pre-analytical treatments like pre-storage centrifugation, filtration, and addition of the bacteriostatic preservative sodium azide. Appreciable changes in the profiles, reflecting changes in the concentration of a number of metabolites, were detected and discussed in terms of chemical and enzymatic reactions for both blood and urine samples. Appropriate procedures for blood derivatives collection and urine preservation/storage that allow maintaining as much as possible the original metabolic profile of the fresh samples emerge, and are proposed as SOPs for biobanking.

  18. Biomonitoring of perfluorinated compounds in a drop of blood.

    PubMed

    Mao, Pan; Wang, Daojing

    2015-06-02

    Biomonitoring of pollutants and their metabolites and derivatives using biofluids provides new opportunities for spatiotemporal assessment of human risks to environmental exposures. Perfluorinated compounds (PFCs) have been used widely in industry and pose significant environmental concerns due to their stability and bioaccumulation in humans and animals. However, current methods for extraction and measurement of PFCs require relatively large volumes (over one hundred microliters) of blood samples, and therefore, are not suitable for frequent blood sampling and longitudinal biomonitoring of PFCs. We have developed a new microassay, enabled by our silicon microfluidic chip platform, for analyzing PFCs in small volumes (less than five microliters) of blood. Our assay integrates on-chip solid-phase extraction (SPE) with online nanoflow liquid chromatography-electrospray ionization-mass spectrometry (nanoLC-ESI-MS) detection. We demonstrated high sample recovery, excellent interday and intraday accuracy and precision, and a limit of detection down to 50 femtogram of PFCs, in one microliter of human plasma. We validated our assay performance using pooled human plasma and NIST SRM 1950 samples. Our microfluidic chip-based assay may enable frequent longitudinal biomonitoring of PFCs and other environmental toxins using a finger prick of blood, thereby providing new insights into their bioaccumulation, bioavailability, and toxicity.

  19. Low Temperature Atmospheric Argon Plasma: Diagnostics and Medical Applications

    NASA Astrophysics Data System (ADS)

    Ermolaeva, Svetlana; Petrov, Oleg; Zigangirova, Nailya; Vasiliev, Mikhail; Sysolyatina, Elena; Antipov, Sergei; Alyapyshev, Maxim; Kolkova, Natalia; Mukhachev, Andrei; Naroditsky, Boris; Shimizu, Tetsuji; Grigoriev, Anatoly; Morfill, Gregor; Fortov, Vladimir; Gintsburg, Alexander

    This study was devoted to diagnostic of low temperature plasma produced by microwave generator and investigation of its bactericidal effect against bacteria in biofilms and within eukaryotic cells. The profile of gas temperature near the torch outlet was measured. The spectrum in a wide range of wavelengths was derived by the method of optical emission spec-troscopy. Probe measurements of the floating potential of plasma were car-ried out. The estimation and adaptation of parameters of plasma flow (tem-perature, velocity, ion number density) according to medico-technical requirements were produced. The model of immersed surface-associated biofilms formed by Gram-negative bacteria, Pseudomonas aeruginosa and Burkholderia cenocepacia, and Gram-positive bacteria, Staphylococcus aureus, was used to assess bactericidal effects of plasma treatment. Reduction in the concentration of live bacteria in biofilms treated with plasma for 5 min was demonstrated by measuring Live/Dead fluorescent labeling and using direct plating. The intracellular infection model with the pathogenic bacterium, Chlamydia trachomatis, was used to study the efficacy of microwave argon plasma against intracellular parasites. A 2 min plasma treatment of mouse cells infected with C. trachomatis reduced infectious bacteria by a factor of 2×106. Plasma treatment diminished the number of viable host cells by about 20%. When the samples were covered with MgF2 glass to obstruct active particles and UV alone was applied, the bactericidal effect was re-duced by 5×104 fold compared to the whole plasma.

  20. Circulating Microparticles Alter Formation, Structure, and Properties of Fibrin Clots.

    PubMed

    Zubairova, Laily D; Nabiullina, Roza M; Nagaswami, Chandrasekaran; Zuev, Yuriy F; Mustafin, Ilshat G; Litvinov, Rustem I; Weisel, John W

    2015-12-04

    Despite the importance of circulating microparticles in haemostasis and thrombosis, there is limited evidence for potential causative effects of naturally produced cell-derived microparticles on fibrin clot formation and its properties. We studied the significance of blood microparticles for fibrin formation, structure, and susceptibility to fibrinolysis by removing them from platelet-free plasma using filtration. Clots made in platelet-free and microparticle-depleted plasma samples from the same healthy donors were analyzed in parallel. Microparticles accelerate fibrin polymerisation and support formation of more compact clots that resist internal and external fibrinolysis. These variations correlate with faster thrombin generation, suggesting thrombin-mediated kinetic effects of microparticles on fibrin formation, structure, and properties. In addition, clots formed in the presence of microparticles, unlike clots from the microparticle-depleted plasma, contain 0.1-0.5-μm size granular and CD61-positive material on fibres, suggesting that platelet-derived microparticles attach to fibrin. Therefore, the blood of healthy individuals contains functional microparticles at the levels that have a procoagulant potential. They affect the structure and stability of fibrin clots indirectly through acceleration of thrombin generation and through direct physical incorporation into the fibrin network. Both mechanisms underlie a potential role of microparticles in haemostasis and thrombosis as modulators of fibrin formation, structure, and resistance to fibrinolysis.

  1. Circulating Microparticles Alter Formation, Structure, and Properties of Fibrin Clots

    PubMed Central

    Zubairova, Laily D.; Nabiullina, Roza M.; Nagaswami, Chandrasekaran; Zuev, Yuriy F.; Mustafin, Ilshat G.; Litvinov, Rustem I.; Weisel, John W.

    2015-01-01

    Despite the importance of circulating microparticles in haemostasis and thrombosis, there is limited evidence for potential causative effects of naturally produced cell-derived microparticles on fibrin clot formation and its properties. We studied the significance of blood microparticles for fibrin formation, structure, and susceptibility to fibrinolysis by removing them from platelet-free plasma using filtration. Clots made in platelet-free and microparticle-depleted plasma samples from the same healthy donors were analyzed in parallel. Microparticles accelerate fibrin polymerisation and support formation of more compact clots that resist internal and external fibrinolysis. These variations correlate with faster thrombin generation, suggesting thrombin-mediated kinetic effects of microparticles on fibrin formation, structure, and properties. In addition, clots formed in the presence of microparticles, unlike clots from the microparticle-depleted plasma, contain 0.1–0.5-μm size granular and CD61-positive material on fibres, suggesting that platelet-derived microparticles attach to fibrin. Therefore, the blood of healthy individuals contains functional microparticles at the levels that have a procoagulant potential. They affect the structure and stability of fibrin clots indirectly through acceleration of thrombin generation and through direct physical incorporation into the fibrin network. Both mechanisms underlie a potential role of microparticles in haemostasis and thrombosis as modulators of fibrin formation, structure, and resistance to fibrinolysis. PMID:26635081

  2. First identification of dimethoxycinnamic acids in human plasma after coffee intake by liquid chromatography-mass spectrometry.

    PubMed

    Nagy, Kornél; Redeuil, Karine; Williamson, Gary; Rezzi, Serge; Dionisi, Fabiola; Longet, Karin; Destaillats, Frédéric; Renouf, Mathieu

    2011-01-21

    There is a substantial amount of published literature on the bioavailability of various coffee components including the most abundant metabolites, caffeic and ferulic acids. Surprisingly, to date, the appearance of dimethoxycinnamic acid derivatives in humans has not been reported despite the fact that methylated form of catechol-type polyphenols could help maintain, modify or even improve their biological activities. This study reports an LC-MS method for the detection of dimethoxycinnamic acid in human plasma after treatment with an esterase. Liquid chromatography, including the combination of methanol and acetonitrile as organic eluent, was optimized to resolve all interferences and enable reliable detection and identification of 3,4-dimethoxycinnamic and 3,4-dimethoxy-dihydrocinnamic acids. In addition to the good mass accuracy achieved (better than 5 ppm), tandem mass spectrometric and co-chromatography experiments further confirmed the identity of the compounds. The optimized method was applied to analyze samples obtained immediately, 1 and 10 h after coffee ingestion. The results show that in particular 3,4-dimethoxycinnamic acid appears in high abundance (∼380 nM at 60 min) in plasma upon coffee intake, indicating that it is important to consider these derivatives in future bioavailability and bioefficacy studies. Copyright © 2010 Elsevier B.V. All rights reserved.

  3. Do Resting Plasma β-Endorphin Levels Predict Responses to Opioid Analgesics?

    PubMed

    Bruehl, Stephen; Burns, John W; Gupta, Rajnish; Buvanendran, Asokumar; Chont, Melissa; Orlowska, Daria; Schuster, Erik; France, Christopher R

    2017-01-01

    Clinically feasible predictors of opioid analgesic responses for use in precision pain medicine protocols are needed. This study evaluated whether resting plasma β-endorphin (BE) levels predicted responses to an opioid analgesic, and whether chronic pain status or sex moderated these effects. Participants included 73 individuals with chronic low back pain (CLBP) and 88 pain-free controls, all using no daily opioid analgesics. Participants attended 2 identical laboratory sessions during which they received either intravenous morphine (0.08 mg/kg) or saline placebo, with blood samples obtained before drug administration to assay resting plasma BE levels. Once peak drug activity was achieved in each session, participants engaged in an ischemic forearm pain task (ISC) and a heat pain task. Morphine analgesic effects were derived reflecting the difference in pain outcomes between placebo and morphine conditions. In hierarchical regressions, significant Type (CLBP vs. control)×BE interactions (Ps<0.05) were noted for morphine effects on ISC tolerance, ISC intratask pain ratings, and thermal VAS unpleasantness ratings. These interactions derived primarily from associations between higher BE levels and smaller morphine effects restricted to the CLBP subgroup. All other BE-related effects, including sex interactions, for predicting morphine analgesia failed to reach statistical significance. BE was a predictor of morphine analgesia for only 3 out of 9 outcomes examined, with these effects moderated by chronic pain status but not sex. On the whole, results do not suggest that resting plasma BE levels are likely to be a clinically useful predictor of opioid analgesic responses.

  4. Bioavailability of phenolics from an oleuropein-rich olive (Olea europaea) leaf extract and its acute effect on plasma antioxidant status: comparison between pre- and postmenopausal women.

    PubMed

    García-Villalba, R; Larrosa, M; Possemiers, S; Tomás-Barberán, F A; Espín, J C

    2014-06-01

    Preclinical studies suggest a potential protective effect of oleuropein in osteoporosis, and one of the proposed mechanisms is the modulation of the oxidative stress. Oleuropein bioavailability and its effect on antioxidant status in pre- and postmenopausal women are unknown. The aim of the present study was to investigate the oral bioavailability of an olive leaf extract rich in oleuropein (40 %) and its effect on antioxidant status in postmenopausal women compared to premenopausal women. Premenopausal (n = 8) and postmenopausal women (n = 8) received 250 mg of olive leaf extract, blood samples (t = 0, 1, 2, 3, 4, 6, 8, 12, 16 and 24 h) were taken, and 24-h urine divided into five fractions was collected. Olive-leaf-extract-derived metabolites were analyzed in plasma and urine by HPLC-ESI-QTOF and UPLC-ESI-QqQ, and pharmacokinetics parameters were determined. Ferric reducing antioxidant ability and malondialdehyde levels were measured in plasma. Plasma levels of hydroxytyrosol glucuronide, hydroxytyrosol sulfate, oleuropein aglycon glucuronide and oleuropein aglycon derivative 1 were higher in postmenopausal women. MDA levels were significantly decreased (32%) in postmenopausal women and inversely correlated with hydroxytyrosol sulfate levels. Postmenopausal women excreted less sulfated metabolites in urine than premenopausal women. Our results suggest that postmenopausal women could be a target population for the intake of olive phenolics in order to prevent age-related and oxidative stress-related processes such as osteoporosis.

  5. Plasma Distribution in Mercury's Magnetosphere Derived from MESSENGER Magnetometer and Fast Imaging Plasma Spectrometer Observations

    NASA Technical Reports Server (NTRS)

    Korth, Haje; Anderson, Brian J.; Gershman, Daniel J.; Raines, Jim M.; Slavin, James A.; Zurbuchen, Thomas H.; Solomon, Sean C.; McNutt, Ralph L.

    2014-01-01

    We assess the statistical spatial distribution of plasma in Mercury's magnetosphere from observations of magnetic pressure deficits and plasma characteristics by the MErcury Surface, Space ENvironment, GEochemistry, and Ranging (MESSENGER) spacecraft. The statistical distributions of proton flux and pressure were derived from 10months of Fast Imaging Plasma Spectrometer (FIPS) observations obtained during the orbital phase of the MESSENGER mission. The Magnetometer-derived pressure distributions compare favorably with those deduced from the FIPS observations at locations where depressions in the magnetic field associated with the presence of enhanced plasma pressures are discernible in the Magnetometer data. The magnitudes of the magnetic pressure deficit and the plasma pressure agree on average, although the two measures of plasma pressure may deviate for individual events by as much as a factor of approximately 3. The FIPS distributions provide better statistics in regions where the plasma is more tenuous and reveal an enhanced plasma population near the magnetopause flanks resulting from direct entry of magnetosheath plasma into the low-latitude boundary layer of the magnetosphere. The plasma observations also exhibit a pronounced north-south asymmetry on the nightside, with markedly lower fluxes at low altitudes in the northern hemisphere than at higher altitudes in the south on the same field line. This asymmetry is consistent with particle loss to the southern hemisphere surface during bounce motion in Mercury's offset dipole magnetic field.

  6. A successful experience of the Iranian blood transfusion organization in improving accessibility and affordability of plasma derived medicine.

    PubMed

    Chegini, Azita; Torab, Seyed Ardeshir; Pourfatollah, Ali Akbar

    2017-02-01

    Plasma is the liquid part of blood. It is estimated 21.6 million liters of plasma collect from Whole blood annually. From these plasma, 4.2 million liters transfuse, 8.1 million liters fractionate, 9.3 million liters waste. Nowadays, blood products and PDM (plasma derived medicine) consider as essential medicine in modern health care and transfusion medicine. Iranian blood transfusion organization as a non-profit organization was established in 1974 in order to centralize all blood transfusion activities from donor recruitment to distribution of blood components to hospitals. Iran is the only country in EMR region with the rate of 20-29.9 blood donations per 1000 population and reached 100% voluntary non-remunerated blood donation in 2007. RBCs and platelets demand are much more than FFPs so the IBTO was faced the surplus plasma that could cause surplus plasma wastage. Simultaneously, hospitals need more plasma derived medicine especially albumin, IVIG, factor VIII, factor IX. IBTO was faced the challenges such as Fractionators selection, Plasma volume shipment, Contract duration, Product profile, Multiple External audits, Cold chain maintenance, Transporting plasma across international borders, NAT test. To overcome plasma wastage and storage of PDM. IBTO involved toll manufacturing in 2005 and not only prevents plasma wastage but also save MOH (ministry of health) budget. Copyright © 2016. Published by Elsevier Ltd.

  7. The complexity of oral physiology and its impact on salivary diagnostics.

    PubMed

    Helmerhorst, E J; Dawes, C; Oppenheim, F G

    2018-04-01

    Saliva contains biomarkers for systemic as well as oral diseases. This study was undertaken to assess the variability in the sources of such biomarkers (plasma, cells) and attempted to identify saliva deterioration markers in order to improve saliva diagnostic outcomes. Inter- and intrasubject variations in salivary gingival crevicular fluid levels were determined by measuring salivary albumin and transferrin levels. The purity of collected glandular secretions was determined by bacterial culture, and the variability in epithelial cell numbers by cell counting and optical density measurement. Saliva sample deterioration markers were identified by RP-HPLC and LC-ESI-MS/MS. Tenfold variations were observed in plasma-derived albumin and transferrin levels, emphasizing the need for biomarker normalization with respect to plasma contributions to saliva. Epithelial cell levels varied 50-fold in samples collected before and after a meal. Salivary fungal levels varied within subjects and among subjects from 0 to >1,000 colony-forming units per milliliter. In saliva samples incubated for various time intervals at 37°C, five peptides were identified that steadily increased in intensity over time and which could be explored as "deterioration markers." Taking saliva characteristics appropriately into account will help realize the promise that this body fluid is suitable to be exploited for reliable healthcare monitoring and surveillance. Published 2017. This article is a U.S. Government work and is in the public domain in the USA.

  8. Alpha-spectrometry and fractal analysis of surface micro-images for characterisation of porous materials used in manufacture of targets for laser plasma experiments

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Aushev, A A; Barinov, S P; Vasin, M G

    2015-06-30

    We present the results of employing the alpha-spectrometry method to determine the characteristics of porous materials used in targets for laser plasma experiments. It is shown that the energy spectrum of alpha-particles, after their passage through porous samples, allows one to determine the distribution of their path length in the foam skeleton. We describe the procedure of deriving such a distribution, excluding both the distribution broadening due to statistical nature of the alpha-particle interaction with an atomic structure (straggling) and hardware effects. The fractal analysis of micro-images is applied to the same porous surface samples that have been studied bymore » alpha-spectrometry. The fractal dimension and size distribution of the number of the foam skeleton grains are obtained. Using the data obtained, a distribution of the total foam skeleton thickness along a chosen direction is constructed. It roughly coincides with the path length distribution of alpha-particles within a range of larger path lengths. It is concluded that the combined use of the alpha-spectrometry method and fractal analysis of images will make it possible to determine the size distribution of foam skeleton grains (or pores). The results can be used as initial data in theoretical studies on propagation of the laser and X-ray radiation in specific porous samples. (laser plasma)« less

  9. Comparison of biochemical values in serum and plasma, fresh and frozen plasma, and hemolyzed samples from orange-winged Amazon parrots (Amazona amazonica).

    PubMed

    Hawkins, Michelle G; Kass, Philip H; Zinkl, Joseph G; Tell, Lisa A

    2006-06-01

    To the authors' knowledge, on the basis of sample type, storage condition, or hemolysis, differences in serum and plasma biochemical values have not been evaluated in orange-winged Amazon parrots (Amazona amazonica). The purpose of this study was to compare values for biochemical analytes in serum vs plasma, fresh vs frozen plasma, and nonhemolyzed vs hemolyzed samples in orange-winged Amazon parrots. We also compared differences in serum and plasma yield from whole-blood aliquots. Fifteen biochemical analytes were evaluated in paired serum and plasma, fresh and frozen plasma, nonhemolyzed and hemolyzed serum and plasma samples from orange-winged Amazon parrots (n = 10) using a wet reagent analyzer. Hemolysis was assessed qualitatively (visually) and quantitatively (hemoglobin [Hgb] measured spectrophotometrically). Serum and plasma yields from 500-microl whole-blood aliquots were determined from centrifuged samples. Analyte values significantly differed among sample groups, but were still within published reference intervals, with the exception of increases in potassium concentration in markedly hemolyzed serum and plasma samples. Clinically important changes in hemolyzed serum and plasma samples included increases in potassium, phosphorus, and albumin concentrations and lactate dehydrogenase activity. The degree of hemolysis assigned qualitatively did not correlate with quantitative Hgb concentration. A significantly greater yield of plasma (288 +/- 13 microL) than serum (241 +/- 44 microL) was obtained. Significant differences may occur in different sample types, however, only changes in potassium, phosphorus, albumin, and lactate dehydrogenase values in hemolyzed samples were considered clinically relevant. Lack of agreement between qualitative and quantitative Hgb concentration indicates the unreliability of visual estimation. Based on higher sample yield, and lack of clinically relevant differences from serum, plasma is a better sample choice for clinical chemistry analysis in birds.

  10. Expression profiles and clinical value of plasma exosomal Tim-3 and Galectin-9 in non-small cell lung cancer.

    PubMed

    Gao, Jianwei; Qiu, Xiangyu; Li, Xinying; Fan, Hang; Zhang, Fang; Lv, Tangfeng; Song, Yong

    2018-04-06

    Exosomes are membrane-bound, virus-sized vesicles present in circulating blood. Tumor cells are avid producers of exosomes, which are thought to mimic molecular features of parent tumor cells. T-cell immunoglobulin- and mucin-domain-containing molecule 3 (Tim-3) is a the next-generation immune checkpoint that can be activated by its ligand Galectin-9 to negatively regulate the anti-tumor immune response. However, the characteristics of plasma exosomal Tim-3 and Galectin-9 (Exo-T/G) in cancer remained unknown. This study was conducted to investigate the expression patterns and clinical value of plasma exosomal total protein (Exo-pro) and Exo-T/G in non-small cell lung cancer (NSCLC). Plasma was collected from 103 NSCLC patients including 60 early stages and 43 advanced stages disease samples as well as 56 healthy subjects. Exosomes were isolated from plasma by commercial exosome precipitation solution and identified by western blotting of CD63 and transmission electron microscopy. Exo-pro concentration was measured by the BCA assay. Enzyme-linked immunosorbent assay was used to quantify Exo-T/G. Additionally, 34 NSCLC samples were applied to directly detect plasma TIM-3 (Plas-T) and Galectin-9 (Plas-G). Our results showed that Exo-pro, Exo-T, and Exo-G were significantly increased in NSCLC plasma compared to that in the healthy samples. High levels of Exo-T and Exo-G were all positively correlated with several malignant parameters, including larger tumor size, advanced stages, and more distant metastasis. High levels of Exo-pro and Exo-T were also correlated with more lymph node metastasis. Additionally, plasma from lung squamous cell carcinoma showed higher Exo-T and Exo-G compared with that from lung adenocarcinoma. ALK-positive patients showed to have decreased Exo-T and Exo-G levels. Pearson's correlation analysis revealed a significant correlation between Exo-pro and Exo-T/G, Exo-T and Exo-G, Exo-T and Plas-T, Exo-G and Plas-G, and Plas-T and Plas-G. Together, our data revealed that Exo-pro, especially Exo-T and Exo-G could be potential biomarkers for NSCLC. Further studies focusing on pure tumor-derived exosomes isolated from plasma were needed. Copyright © 2018 Elsevier Inc. All rights reserved.

  11. The turnover and transport of vitamin D and of a polar metabolite with the properties of 25-hydroxycholecalciferol in human plasma

    PubMed Central

    Smith, John Edgar; Goodman, DeWitt S.

    1971-01-01

    Four normal men were injected intravenously with physiological doses (6 μg) of vitamin D3-1,2-3H. Serial samples of plasma were collected for 50 days. Total lipid extracts were chromatographed on silicic acid columns or thin-layer plates in order to characterize the radioactive components. Labeled vitamin D3 disappeared rapidly from plasma (initial half-life approximately 12 hr); after 7 days unchanged vitamin D3 represented less than 1% of circulating radioactivity. Coincident with vitamin D3 disappearance a more polar labeled metabolite appeared with chromatographic and other properties identical with those of 25-hydroxycholecalciferol. The disappearance of the more polar metabolite was relatively slow with a half-life of 19.6 ±0.6 days. A similar half-life was seen in a fifth subject, injected with 80 μg of vitamin D3-3H. Most (approximately 92%) of the plasma total radioactivity was represented by this component throughout the study. Plasma samples collected at various times were adjusted to density (d) 1.21 and were ultracentrifuged to separate plasma lipoproteins from proteins with d > 1.21. In all samples, almost all (mean 94%) of the radioactivity was found in association with proteins of d > 1.21. This observation was confirmed by bioassay, measuring uptake of 45Ca by intestinal slices. All plasma bioassayable vitamin D was found in association with proteins of d > 1.21; 55% of bioactivity was found in the chromatographic fraction corresponding to 25-hydroxycholecalciferol and 44% in the fractions representing vitamin D3. Since both vitamin D3 and its 25-hydroxy metabolite are lipid-soluble sterol derivatives, the finding that these compounds do not circulate in association with the known plasma lipoproteins provides presumptive evidence for the existence of a specific transport protein of d > 1.21. The transport protein for the polar metabolite has been partly characterized by gel filtration on Sephadex G-200 and by electrophoresis on polyacrylamide gel. The protein has an apparent size slightly smaller than plasma albumin (approximate mol wt 50,000-60,000) and an electrophoretic mobility very slightly greater than that of albumin. Studies are in progress to fractionate further and to characterize the transport protein. Images PMID:4330006

  12. Protocols for the measurement of the F2-isoprostane, 15(S)-8-iso-prostaglandin F2α, in biological samples by GC-MS or GC-MS/MS coupled with immunoaffinity column chromatography.

    PubMed

    Tsikas, Dimitrios; Suchy, Maria-Theresia

    2016-04-15

    Arachidonic acid, the origin of the eicosanoids family, occurs in biological samples as free acid and as ester in lipids. Free arachidonic acid is oxidized to numerous metabolites by means of enzymes including cyclooxygenase (COX). Arachidonic acid esterified to lipids is attacked by reactive oxygen species (ROS) to generate numerous oxidized arachidonic acid derivatives. Generally, it is assumed that ROS-derived arachidonic acid derivatives are distinct from those generated by enzymes such as COX. Therefore, ROS-generated eicosanoids are considered specific biomarkers of oxidative stress. However, there are serious doubts concerning a strict distinction between the enzyme-derived eicosanoids and the ROS-derived iso-eicosanoids. Prominent examples are prostaglandin F2α (PGF2α) and 15(S)-8-iso-prostaglandin F2α (15(S)-8-iso-PGF2α) which have been originally considered to exclusively derive from COX and ROS, respectively. There is convincing evidence that both COX and ROS can oxidize arachidonic acid to PGF2α and 15(S)-8-iso-PGF2α. Thus, many results previously reported for 15(S)-8-iso-PGF2α as exclusive ROS-dependent reaction product, and consequently as a specific biomarker of oxidative stress, require a careful re-examination which should also consider the analytical methods used to measure 15(S)-8-iso-PGF2α. This prominent but certainly not the only example underlines more than ever the importance of the analytical chemistry in basic and clinical research areas of oxidative stress. In the present work, we report analytical protocols for the reliable quantitative determination of 15(S)-8-iso-PGF2α in human biological samples including plasma and urine by mass spectrometry coupled to gas chromatography (GC-MS, GC-MS/MS) after specific isolation of endogenous 15(S)-8-iso-PGF2α and the externally added internal standard [3,3',4,4'-(2)H4]-15(S)-8-iso-PGF2α by immunoaffinity column chromatography (IAC). 15(S)-8-iso-PGF2α esterified to plasma lipids is hydrolysed by KOH. 15(S)-8-iso-PGF2α and [3,3',4,4'-(2)H4]-15(S)-8-iso-PGF2α are analyzed as pentafluorobenzyl ester trimethylsilyl ether derivatives in the electron-capture negative-ion chemical ionization mode. Copyright © 2014 Elsevier B.V. All rights reserved.

  13. The use of frozen plasma samples in thromboelastometry.

    PubMed

    Schoergenhofer, Christian; Buchtele, Nina; Schwameis, Michael; Bartko, Johann; Jilma, Bernd; Jilma-Stohlawetz, Petra

    2017-11-01

    Thromboelastometry is increasingly used in the clinical and scientific setting. The use of frozen plasma samples may be useful in overcoming certain limitations such as local and timely availability. Whole blood (WB) samples of 20 healthy volunteers were obtained, and plasma was generated. NATEM (n = 20), EXTEM (n = 20) and INTEM (n = 8) analyses were performed in WB, fresh plasma and frozen and thawed plasma. Dabigatran (500, 1000 ng/ml), rivaroxaban (100, 200 ng/ml) or alteplase (333 ng/ml) were added ex vivo to WB, and thromboelastometry was performed in WB and in frozen and thawed plasma samples. Clot formation time, mean clot firmness and the area under the curve were significantly altered in plasma compared to WB. In INTEM and EXTEM analysis, clotting time (CT) was comparable between WB (100%) and fresh (INTEM 114% and EXTEM 93%, ratio of the means) and frozen plasma samples (85 and 99%), whereas in NATEM analysis, the CT increased in fresh (193%) and frozen plasma samples (130%). Dabigatran dose-dependently increased the CT approximately 5- and 9-fold in WB and even more pronounced 10- and 26-fold in plasma. Accordingly, rivaroxaban dose-dependently increased the CT 2- and 2.7-fold in WB, and 3.5- and 4-fold in plasma samples. Hyperfibrinolysis was achieved by addition of alteplase in all WB samples and was reproducible in plasma samples. In conclusion, thromboelastometry, especially INTEM and EXTEM analyses, is possible using frozen and stored plasma samples with comparable results to the corresponding whole blood samples.

  14. Macrophage Migration Inhibitory Factor for the Early Prediction of Infarct Size

    PubMed Central

    Chan, William; White, David A.; Wang, Xin‐Yu; Bai, Ru‐Feng; Liu, Yang; Yu, Hai‐Yi; Zhang, You‐Yi; Fan, Fenling; Schneider, Hans G.; Duffy, Stephen J.; Taylor, Andrew J.; Du, Xiao‐Jun; Gao, Wei; Gao, Xiao‐Ming; Dart, Anthony M.

    2013-01-01

    Background Early diagnosis and knowledge of infarct size is critical for the management of acute myocardial infarction (MI). We evaluated whether early elevated plasma level of macrophage migration inhibitory factor (MIF) is useful for these purposes in patients with ST‐elevation MI (STEMI). Methods and Results We first studied MIF level in plasma and the myocardium in mice and determined infarct size. MI for 15 or 60 minutes resulted in 2.5‐fold increase over control values in plasma MIF levels while MIF content in the ischemic myocardium reduced by 50% and plasma MIF levels correlated with myocardium‐at‐risk and infarct size at both time‐points (P<0.01). In patients with STEMI, we obtained admission plasma samples and measured MIF, conventional troponins (TnI, TnT), high sensitive TnI (hsTnI), creatine kinase (CK), CK‐MB, and myoglobin. Infarct size was assessed by cardiac magnetic resonance (CMR) imaging. Patients with chronic stable angina and healthy volunteers were studied as controls. Of 374 STEMI patients, 68% had elevated admission MIF levels above the highest value in healthy controls (>41.6 ng/mL), a proportion similar to hsTnI (75%) and TnI (50%), but greater than other biomarkers studied (20% to 31%, all P<0.05 versus MIF). Only admission MIF levels correlated with CMR‐derived infarct size, ventricular volumes and ejection fraction (n=42, r=0.46 to 0.77, all P<0.01) at 3 day and 3 months post‐MI. Conclusion Plasma MIF levels are elevated in a high proportion of STEMI patients at the first obtainable sample and these levels are predictive of final infarct size and the extent of cardiac remodeling. PMID:24096574

  15. STS-3/OSS-1 Plasma Diagnostics Package (PDP) measurements of Orbiter transmitter and subsystem electromagnetic interference

    NASA Technical Reports Server (NTRS)

    Shawhan, S. D.; Murphy, G.

    1983-01-01

    The plasma diagnostics package receiver system is described to identify the various antennas and to characterize the complement of receivers which cover the frequency range of 30 Hz to 800 Hz and S-band at 2200 + or - 300 MHz. Sample results are presented to show the variability of electromagnetic effects associated with the orbiter and the time variability of these effects. The electric field and magnetic field maximum and minimum field strength spectra observed during the mission at the pallet location are plotted. Values are also derived for the maximum UHF transmitter and S-band transmitter field strengths. Calibration data to convert from the survey plots to actual narrowband and broadband field strengths are listed.

  16. Plasma appearance and correlation between coffee and green tea metabolites in human subjects.

    PubMed

    Renouf, Mathieu; Guy, Philippe; Marmet, Cynthia; Longet, Karin; Fraering, Anne-Lise; Moulin, Julie; Barron, Denis; Dionisi, Fabiola; Cavin, Christophe; Steiling, Heike; Williamson, Gary

    2010-12-01

    Coffee and green tea are two of the most widely consumed hot beverages in the world. Their respective bioavailability has been studied separately, but absorption of their respective bioactive phenolics has not been compared. In a randomised cross-over design, nine healthy subjects drank instant coffee and green tea. Blood samples were collected over 12 h and at 24 h to assess return to baseline. After green tea consumption, (-)-epigallocatechin (EGC) was the major catechin, appearing rapidly in the plasma; (-)-EGC gallate (EGCg) and (-)-epicatechin (EC) were also present, but (-)-EC gallate and C were not detected. Dihydroferulic acid and dihydrocaffeic acid were the major metabolites that appeared after coffee consumption with a long time needed to reach maximum plasma concentration, suggesting metabolism and absorption in the colon. Other phenolic acid equivalents (caffeic acid (CA), ferulic acid (FA) and isoferulic acid (iFA)) were detected earlier, and they peaked at lower concentrations. Summations of the plasma area under the curves (AUC) for the measured metabolites showed 1.7-fold more coffee-derived phenolic acids than green tea-derived catechins (P = 0.0014). Furthermore, we found a significant correlation between coffee metabolites based on AUC. Inter-individual differences were observed, but individuals with a high level of CA also showed a correspondingly high level of FA. However, no such correlation was observed between the tea catechins and coffee phenolic acids. Correlation between AUC and maximum plasma concentration was also significant for CA, FA and iFA and for EGCg. This implies that the mechanisms of absorption for these two classes of compounds are different, and that a high absorber of phenolic acids is not necessarily a high absorber of catechins.

  17. Study of plasma-derived miRNAs mimic differences in Huntington's disease brain.

    PubMed

    Hoss, Andrew G; Lagomarsino, Valentina N; Frank, Samuel; Hadzi, Tiffany C; Myers, Richard H; Latourelle, Jeanne C

    2015-12-01

    Biomarkers for Huntington's disease progression could accelerate therapeutic developments and improve patient care. Brain microRNAs relating to clinical features of Huntington's disease may represent a potential Huntington's disease biomarker in blood. This study was undertaken to examine candidate microRNAs in plasma to determine whether changes observed in HD brains are detectable in peripheral samples. Four microRNAs from 26 manifest Huntington's disease, four asymptomatic Huntington's disease gene carriers, and eight controls were quantified in plasma using reverse transcription quantitative polymerase chain reaction. Linear regression was used to assess microRNA levels across control, asymptomatic gene carriers, and manifest patients. miR-10b-5p (P = 0.0068) and miR-486-5p (P = 0.044) were elevated in Huntington's disease plasma. miR-10b-5p was decreased in asymptomatic gene carriers as compared with patients with Huntington's disease (P = 0.049), but no difference between asymptomatic gene carriers and healthy controls was observed (P = 0.24). These findings suggest that microRNA changes observed in Huntington's disease brain may be detectable in plasma and have potential clinical utility. © 2015 International Parkinson and Movement Disorder Society.

  18. Reliability of plasma fibroblast growth factor 23 as risk biomarker in epidemiological studies measured over a four-month period.

    PubMed

    di Giuseppe, Romina; Hirche, Frank; Montonen, Jukka; Buijsse, Brian; Dierkes, Jutta; Stangl, Gabriele I; Boeing, Heiner; Weikert, Cornelia

    2012-11-01

    Identified as a biomarker of altered calcium-phosphorus metabolism in chronic kidney disease, fibroblast growth factor 23 (FGF-23) can also be used as a biomarker of risk for cardiovascular disease in the general population. However, it is crucial to first evaluate the reproducibility (reliability) of plasma FGF-23 concentrations. We assessed the reliability of plasma FGF-23 concentrations using replicate blood samples taken four months apart of 207 participants from the European Prospective Investigation into Cancer and Nutrition-Potsdam Study. Plasma FGF-23 concentrations at baseline (geometric mean: 24.7 RU/mL; 95% confidence interval [CI] in RU/mL: 21.8-27.9) were not significantly different from those measured four months later (geometric mean: 23.7 RU/mL; 95% CI in RU/mL: 20.6-27.1; P = 0.42). The intraclass correlation coefficients were 0.69 (95% CI: 0.62-0.76) for all; 0.64 (95% CI: 0.50-0.75) for men and 0.73 (95% CI: 0.64-0.81) for women. Plasma FGF-23 concentrations showed good reliability over time. Our findings suggest that in epidemiological studies, a single plasma FGF-23 measurement may be sufficient to derive the relative risk in prospective cohort studies.

  19. Derivatization of beta-dicarbonyl compound with 2,4-dinitrophenylhydrazine to enhance mass spectrometric detection: application in quantitative analysis of houttuynin in human plasma.

    PubMed

    Duan, Xiaotao; Zhong, Dafang; Chen, Xiaoyan

    2008-06-01

    Houttuynin (decanoyl acetaldehyde), a beta-dicarbonyl compound, is the major antibacterial constituent in the volatile oil of Houttuynina cordata Thunb. In the present work, detection of houttuynin in human plasma based on the chemical derivatization with 2,4-dinitrophenylhydrazine (DNPH) coupled with liquid chromatography/tandem mass spectrometry was described. The primary reaction products between the beta-dicarbonyl compound and DNPH in aqueous phase were identified as heterocyclic structures, of which the mass spectrometric ionization and fragmentation behavior were characterized with the aid of high-resolution multistage mass spectral analysis. For quantification, houttuynin and internal standard (IS, benzophenone) in plasma were firstly converted to their DNPH derivatives without sample purification, then extracted from human plasma with n-hexane and detected by liquid chromatography tandem mass spectrometry performed in selected reaction monitoring (SRM) mode. This method allowed for a lower limit of quantification (LLOQ) of 1.0 ng/ml using 100-microl plasma. The validation results showed high accuracy (%bias < 2.1) and precision (%CV < 7.2) at broad linear dynamic range (1.0-5000 ng/ml). The simple and quantitative derivatization coupled with tandem mass spectrometric analysis facilitates a sensitive and robust method for the determination of plasma houttuynin in pharmacokinetic studies.

  20. Arbitrary electron acoustic waves in degenerate dense plasmas

    NASA Astrophysics Data System (ADS)

    Rahman, Ata-ur; Mushtaq, A.; Qamar, A.; Neelam, S.

    2017-05-01

    A theoretical investigation is carried out of the nonlinear dynamics of electron-acoustic waves in a collisionless and unmagnetized plasma whose constituents are non-degenerate cold electrons, ultra-relativistic degenerate electrons, and stationary ions. A dispersion relation is derived for linear EAWs. An energy integral equation involving the Sagdeev potential is derived, and basic properties of the large amplitude solitary structures are investigated in such a degenerate dense plasma. It is shown that only negative large amplitude EA solitary waves can exist in such a plasma system. The present analysis may be important to understand the collective interactions in degenerate dense plasmas, occurring in dense astrophysical environments as well as in laser-solid density plasma interaction experiments.

  1. The relationship among dental status, nutrient intake, and nutritional status in older people.

    PubMed

    Sheiham, A; Steele, J G; Marcenes, W; Lowe, C; Finch, S; Bates, C J; Prentice, A; Walls, A W

    2001-02-01

    Dental health status may influence nutrition. The objective of this part of the National Diet and Nutrition Survey was to assess if there is a relationship between dental status in people 65 years and older and intake of certain nutrients and any link between dental status and blood-derived values of key nutrients. Random national samples of independently living subjects and those living in institutions had dental examinations, interviews, four-day food diaries, and blood and urine analyzed. In the sample living independently, intakes of most nutrients were lower in edentate than dentate subjects. Intake of non-starch polysaccharides, protein, calcium, non-heme iron, niacin, and vitamin C was significantly lower in edentate subjects. People with 21 or more teeth consumed more of most nutrients, particularly of non-starch polysaccharide. This relationship in intake was not apparent in the hematological analysis. Plasma ascorbate and plasma retinol were the only analytes significantly associated with dental status.

  2. A generic standard additions based method to determine endogenous analyte concentrations by immunoassays to overcome complex biological matrix interference.

    PubMed

    Pang, Susan; Cowen, Simon

    2017-12-13

    We describe a novel generic method to derive the unknown endogenous concentrations of analyte within complex biological matrices (e.g. serum or plasma) based upon the relationship between the immunoassay signal response of a biological test sample spiked with known analyte concentrations and the log transformed estimated total concentration. If the estimated total analyte concentration is correct, a portion of the sigmoid on a log-log plot is very close to linear, allowing the unknown endogenous concentration to be estimated using a numerical method. This approach obviates conventional relative quantification using an internal standard curve and need for calibrant diluent, and takes into account the individual matrix interference on the immunoassay by spiking the test sample itself. This technique is based on standard additions for chemical analytes. Unknown endogenous analyte concentrations within even 2-fold diluted human plasma may be determined reliably using as few as four reaction wells.

  3. Plasma heating for containerless and microgravity materials processing

    NASA Technical Reports Server (NTRS)

    Leung, Emily W. (Inventor); Man, Kin F. (Inventor)

    1994-01-01

    A method for plasma heating of levitated samples to be used in containerless microgravity processing is disclosed. A sample is levitated by electrostatic, electromagnetic, aerodynamic, or acoustic systems, as is appropriate for the physical properties of the particular sample. The sample is heated by a plasma torch at atmospheric pressure. A ground plate is provided to help direct the plasma towards the sample. In addition, Helmholtz coils are provided to produce a magnetic field that can be used to spiral the plasma around the sample. The plasma heating system is oriented such that it does not interfere with the levitation system.

  4. Analysis of human plasma lipids by using comprehensive two-dimensional gas chromatography with dual detection and with the support of high-resolution time-of-flight mass spectrometry for structural elucidation.

    PubMed

    Salivo, Simona; Beccaria, Marco; Sullini, Giuseppe; Tranchida, Peter Q; Dugo, Paola; Mondello, Luigi

    2015-01-01

    The main focus of the present research is the analysis of the unsaponifiable lipid fraction of human plasma by using data derived from comprehensive two-dimensional gas chromatography with dual quadrupole mass spectrometry and flame ionization detection. This approach enabled us to attain both mass spectral information and analyte percentage data. Furthermore, gas chromatography coupled with high-resolution time-of-flight mass spectrometry was used to increase the reliability of identification of several unsaponifiable lipid constituents. The synergism between both the high-resolution gas chromatography and mass spectrometry processes enabled us to attain a more in-depth knowledge of the unsaponifiable fraction of human plasma. Additionally, information was attained on the fatty acid and triacylglycerol composition of the plasma samples, subjected to investigation by using comprehensive two-dimensional gas chromatography with dual quadrupole mass spectrometry and flame ionization detection and high-performance liquid chromatography with atmospheric pressure chemical ionization quadrupole mass spectrometry, respectively. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  5. Method for determining the concentration of atomic species in gases and solids

    DOEpatents

    Loge, Gary W.

    1998-01-01

    Method for determining the concentration of atomic species in gases and solids. Measurement of at least two emission intensities from a species in a sample that is excited by incident laser radiation. Which generates a plasma therein after a sufficient time period has elapsed and during a second time period, permits an instantaneous temperature to be established within the sample. The concentration of the atomic species to be determined is then derived from the known emission intensity of a predetermined concentration of that species in the sample at the measured temperature, a quantity which is measured prior to the determination of the unknown concentration, and the actual measured emission from the unknown species, or by this latter emission and the emission intensity of a species having known concentration within the sample such as nitrogen for gaseous air samples.

  6. Plasma processing conditions substantially influence circulating microRNA biomarker levels.

    PubMed

    Cheng, Heather H; Yi, Hye Son; Kim, Yeonju; Kroh, Evan M; Chien, Jason W; Eaton, Keith D; Goodman, Marc T; Tait, Jonathan F; Tewari, Muneesh; Pritchard, Colin C

    2013-01-01

    Circulating, cell-free microRNAs (miRNAs) are promising candidate biomarkers, but optimal conditions for processing blood specimens for miRNA measurement remain to be established. Our previous work showed that the majority of plasma miRNAs are likely blood cell-derived. In the course of profiling lung cancer cases versus healthy controls, we observed a broad increase in circulating miRNA levels in cases compared to controls and that higher miRNA expression correlated with higher platelet and particle counts. We therefore hypothesized that the quantity of residual platelets and microparticles remaining after plasma processing might impact miRNA measurements. To systematically investigate this, we subjected matched plasma from healthy individuals to stepwise processing with differential centrifugation and 0.22 µm filtration and performed miRNA profiling. We found a major effect on circulating miRNAs, with the majority (72%) of detectable miRNAs substantially affected by processing alone. Specifically, 10% of miRNAs showed 4-30x variation, 46% showed 30-1,000x variation, and 15% showed >1,000x variation in expression solely from processing. This was predominantly due to platelet contamination, which persisted despite using standard laboratory protocols. Importantly, we show that platelet contamination in archived samples could largely be eliminated by additional centrifugation, even in frozen samples stored for six years. To minimize confounding effects in microRNA biomarker studies, additional steps to limit platelet contamination for circulating miRNA biomarker studies are necessary. We provide specific practical recommendations to help minimize confounding variation attributable to plasma processing and platelet contamination.

  7. Integrity of the Plasma Magnetic Nozzle

    NASA Technical Reports Server (NTRS)

    Gerwin, Richard A.

    2009-01-01

    This report examines the physics governing certain aspects of plasma propellant flow through a magnetic nozzle, specifically the integrity of the interface between the plasma and the nozzle s magnetic field. The injection of 100s of eV plasma into a magnetic flux nozzle that converts thermal energy into directed thrust is fundamental to enabling 10 000s of seconds specific impulse and 10s of kW/kg specific power piloted interplanetary propulsion. An expression for the initial thickness of the interface is derived and found to be approx.10(exp -2) m. An algorithm is reviewed and applied to compare classical resistivity to gradient-driven microturbulent (anomalous) resistivity, in terms of the spatial rate and time integral of resistive interface broadening, which can then be related to the geometry of the nozzle. An algorithm characterizing plasma temperature, density, and velocity dependencies is derived and found to be comparable to classical resistivity at local plasma temperatures of approx. 200 eV. Macroscopic flute-mode instabilities in regions of "adverse magnetic curvature" are discussed; a growth rate formula is derived and found to be one to two e-foldings of the most unstable Rayleigh-Taylor (RT) mode. After establishing the necessity of incorporating the Hall effect into Ohm s law (allowing full Hall current to flow and concomitant plasma rotation), a critical nozzle length expression is derived in which the interface thickness is limited to about 1 ion gyroradius.

  8. Assay of anti-HBs antibodies using a recombinant antigen and latex particle counting: comparison with five commercial tests.

    PubMed

    Galanti, L M; Cornu, C; Masson, P L; Robert, A R; Becheanu, D; Lamy, M E; Cambiaso, C L

    1991-05-01

    An assay of anti-HBs antibodies based on agglutination of latex particles coated with recombinant HBs-antigen was compared with Abbott radioimmunoassay (Abbott-RIA), which uses a human plasma-derived antigen. The population examined consisted of 76 Abbott-RIA anti-HBs-negative prevaccinated subjects and 1044 serum samples anti-HBs found positive by Abbott-RIA, including 283 samples of subjects vaccinated either with a human plasma-derived vaccine (group A; n = 180) or with a recombinant vaccine (group B; n = 103). Correlation coefficients between the two techniques were respectively r = 0.89 for the whole population (n = 1044), r = 0.98 in group A and r = 0.74 in group B. Anti-HBs titres were higher with latex than with RIA in group B as shown by the regression slopes: latex = 508 + 1.11 RIA in group A and latex = -1138 + 3.97 RIA in group B, suggesting that some vaccinated subjects from group B produced antibodies against epitopes proper to the recombinant antigen. In the prevaccinated population and in group A, the latex results were compared with those of radioimmunoassays (Abbott, Sorin) and enzyme immunoassays (Behring, Roche, Pasteur). Only the Roche-EIA detected anti-HBs in the prevaccinated subjects. The correlation between the various immunoassays was r greater than 0.96 only for values higher than 100 IU/l.

  9. Absolute quantitation of low abundance plasma APL1β peptides at sub-fmol/mL Level by SRM/MRM without immunoaffinity enrichment.

    PubMed

    Sano, Shozo; Tagami, Shinji; Hashimoto, Yuuki; Yoshizawa-Kumagaye, Kumiko; Tsunemi, Masahiko; Okochi, Masayasu; Tomonaga, Takeshi

    2014-02-07

    Selected/multiple reaction monitoring (SRM/MRM) has been widely used for the quantification of specific proteins/peptides, although it is still challenging to quantitate low abundant proteins/peptides in complex samples such as plasma/serum. To overcome this problem, enrichment of target proteins/peptides is needed, such as immunoprecipitation; however, this is labor-intense and generation of antibodies is highly expensive. In this study, we attempted to quantify plasma low abundant APLP1-derived Aβ-like peptides (APL1β), a surrogate marker for Alzheimer's disease, by SRM/MRM using stable isotope-labeled reference peptides without immunoaffinity enrichment. A combination of Cibacron Blue dye mediated albumin removal and acetonitrile extraction followed by C18-strong cation exchange multi-StageTip purification was used to deplete plasma proteins and unnecessary peptides. Optimal and validated precursor ions to fragment ion transitions of APL1β were developed on a triple quadruple mass spectrometer, and the nanoliquid chromatography gradient for peptide separation was optimized to minimize the biological interference of plasma. Using the stable isotope-labeled (SI) peptide as an internal control, absolute concentrations of plasma APL1β peptide could be quantified as several hundred amol/mL. To our knowledge, this is the lowest detection level of endogenous plasma peptide quantified by SRM/MRM.

  10. Creation of hydrophilic nitric oxide releasing polymers via plasma surface modification.

    PubMed

    Pegalajar-Jurado, A; Joslin, J M; Hawker, M J; Reynolds, M M; Fisher, E R

    2014-08-13

    Herein, we describe the surface modification of an S-nitrosated polymer derivative via H2O plasma treatment, resulting in polymer coatings that maintained their nitric oxide (NO) releasing capabilities, but exhibited dramatic changes in surface wettability. The poly(lactic-co-glycolic acid)-based hydrophobic polymer was nitrosated to achieve a material capable of releasing the therapeutic agent NO. The NO-loaded films were subjected to low-temperature H2O plasma treatments, where the treatment power (20-50 W) and time (1-5 min) were varied. The plasma treated polymer films were superhydrophilic (water droplet spread completely in <100 ms), yet retained 90% of their initial S-nitrosothiol content. Under thermal conditions, NO release profiles were identical to controls. Under buffer soak conditions, the NO release profile was slightly lowered for the plasma-treated materials; however, they still result in physiologically relevant NO fluxes. XPS, SEM-EDS, and ATR-IR characterization suggests the plasma treatment resulted in polymer rearrangement and implantation of hydroxyl and carbonyl functional groups. Plasma treated samples maintained both hydrophilic surface properties and NO release profiles after storage at -18 °C for at least 10 days, demonstrating the surface modification and NO release capabilities are stable over time. The ability to tune polymer surface properties while maintaining bulk properties and NO release properties, and the stability of those properties under refrigerated conditions, represents a unique approach toward creating enhanced therapeutic biopolymers.

  11. Effects of positive results for Mycobacterium avium subsp paratuberculosis as determined by microbial culture of feces or antibody ELISA on results of caudal fold tuberculin test and interferon-gamma assay for tuberculosis in cattle.

    PubMed

    Dunn, John R; Kaneene, John B; Grooms, Daniel L; Bolin, Steven R; Bolin, Carole A; Bruning-Fann, Colleen S

    2005-02-01

    To determine whether cattle testing positive for Mycobacterium avium subsp paratuberculosis as determined by microbial culture of feces or antibody ELISA were more likely to have false-positive responses on the caudal fold tuberculin (CFT) test or interferon-gamma (IFN-gamma) assay for Mycobacterium bovis than cattle testing negative for M paratuberculosis. 1043 cattle from 10 herds in Michigan. Feces and blood samples for plasma were collected from cattle > or =24 months old on the day the CFT test was read. Fecal samples were submitted for microbial culture for M paratuberculosis. Plasma samples were tested for antibody against M paratuberculosis, and IFN-gamma after stimulation with purified protein derivative tuberculin from M bovis or M avium. Of 1043 cattle, 180 (17.3%) had positive CFT test results (suspects) and 8 (0.8%) had positive IFN-gamma assay results after stimulation with purified protein derivative tuberculin from M bovis. Forty-five (4.3%) and 115 (11.0%) cattle tested positive for M paratuberculosis as determined by microbial culture of feces and antibody ELISA, respectively. Cattle with positive responses for M paratuberculosis appeared to have an increased likelihood of false-positive results on the CFT test, although this association was not significant. No significant association was detected among cattle testing positive for M paratuberculosis as determined by microbial culture of feces and antibody ELISA and positive CFT test and IFN-gamma assay results for M bovis.

  12. Ion composition and temperature in the topside ionosphere.

    NASA Technical Reports Server (NTRS)

    Brace, L. H.; Dunham, G. S.; Mayr, H. G.

    1967-01-01

    Particle and energy continuity equations derived and solved by computer method ion composition and plasma temperature measured by Explorer XXII PARTICLE and energy continuity equations derived and solved by computer method for ion composition and plasma temperature measured by Explorer XXII

  13. Method of high-precision microsampled blood and plasma mass densitometry

    NASA Technical Reports Server (NTRS)

    Hinghofer-Szalkay, H.

    1986-01-01

    The reliability of the mechanical oscillator technique for blood and plasma density measurements on samples of volumes less than 0.1 ml is examined, and a precision of 0.001 g/l is found if plasma-isodensic heparin solution and siliconized densitometers are employed. Sources of measurement errors in the density determinations include storage of plasma samples, inhomogeneity of blood samples, and density reading before adequate temperature equilibration. In tests of plasma sample storage, the best reproducibility was obtained with samples kept at 4 C. Linear correlations were found between plasma density and plasma protein concentration, blood density and blood hemoglobin concentration, and erythrocyte density and MCHC.

  14. Tunable polarization plasma channel undulator for narrow bandwidth photon emission

    DOE PAGES

    Rykovanov, S. G.; Wang, J. W.; Kharin, V. Yu.; ...

    2016-09-09

    The theory of a plasma undulator excited by a short intense laser pulse in a parabolic plasma channel is presented. The undulator fields are generated either by the laser pulse incident off-axis and/or under the angle with respect to the channel axis. Linear plasma theory is used to derive the wakefield structure. It is shown that the electrons injected into the plasma wakefields experience betatron motion and undulator oscillations. Optimal electron beam injection conditions are derived for minimizing the amplitude of the betatron motion, producing narrow-bandwidth undulator radiation. Polarization control is readily achieved by varying the laser pulse injection conditions.

  15. Comparison of proteomic profiles of serum, plasma, and modified media supplements used for cell culture and expansion

    PubMed Central

    Ayache, Saleh; Panelli, Monica C; Byrne, Karen M; Slezak, Stefanie; Leitman, Susan F; Marincola, Francesco M; Stroncek, David F

    2006-01-01

    Background The culture and expansion of human cells for clinical use requires the presence of human serum or plasma in culture media. Although these supplements have been extensively characterized in their chemical composition, only recently it has been possible to provide by high throughput protein analysis, a comprehensive profile of the soluble factors contributing to cell survival. This study analyzed and compared the presence of 100 proteins including chemokines, cytokines and soluble factors in six different types of media supplements: serum, plasma, recalcified plasma, heat inactivated serum, heat inactivated plasma and heat inactivated recalcified plasma. Methods Serum, plasma, recalcified plasma, and heat inactivated supplements were prepared from ten healthy subjects. The levels of 100 soluble factors were measured in each sample using a multiplexed ELISA assay and compared by Eisen hierarchical clustering analysis. Results A comparison of serum and plasma levels of soluble factors found that 2 were greater in plasma but 18 factors were greater in serum including 11 chemokines. The levels of only four factors differed between recalcified plasma and plasma. Heat inactivation had the greatest effect on soluble factors. Supervised Eisen hierarchical clustering indicated that the differences between heat inactivated supplements and those that were not were greater than the differences within these two groups. The levels of 36 factors differed between heat inactivated plasma and plasma. Thirty one of these factors had a lower concentration in heat inactivated plasma including 12 chemokines, 4 growth factors, 4 matrix metalloproteases, and 3 adhesion molecules. Heat inactivated decalcified plasma is often used in place of heat inactivated serum and the levels of 19 soluble factors differed between these two supplements. Conclusion Our report provides a comprehensive protein profile of serum, plasma recalcified plasma, and heat inactivated supplements. This profile represents a qualitative and quantitative database that can aid in the selection of the appropriate blood derived supplement for human cell cultures with special requirements. PMID:17020621

  16. An application of mass spectrometry for quality control of biologicals: Highly sensitive profiling of plasma residuals in human plasma-derived immunoglobulin.

    PubMed

    Limonier, Franck; Van Steendam, Katleen; Waeterloos, Geneviève; Brusselmans, Koen; Sneyers, Myriam; Deforce, Dieter

    2017-01-30

    Thromboembolic events (TEE) associated to trace amounts of plasmatic activated coagulation factor XI (FXIa) in administrated immunoglobulin (Ig) have recently raised concerns and hence there is a need for highly sensitive profiling of residual plasma source proteins. This study aims to consider LC-ESI-QTOF data-dependent acquisition in combination with sample fractionation for this purpose. Sample fractionation proved mandatory to enable identification of plasma residuals. Two approaches were compared: Ig depletion with protein G - protein A affinity chromatography and low-abundant protein enrichment with a combinatorial peptide ligand library (ProteoMiner™, Bio-Rad). The latter allowed a higher number of identifications. Highly sensitive detection of prothrombotic FXIa was assessed with confident identification of a 1ng/mg spike. Moreover, different residuals compositions were profiled for various commercial Ig products. Using a quantitative label free analysis, a TEE-positive Ig batch was distinguished from other regular Ig products, with increased levels of FXIa but also other unique proteins. This could have prevented the recently observed TEE problems with Ig. The method is a convenient tool to better characterize Ig products after any plasma pool or manufacture process change, gaining insights in the product quality profile without any prior information required. This study characterized residual plasma proteins in Ig products, using bottom-up LC-MS/MS with conventional data-dependent acquisition, preceded by sample fractionation. Without any prior information or target-specific development, >30 proteins were identified in a commercial Ig product. Quality control relevance was demonstrated with the identification of FXIa spiked at 1ng/mg in Ig, which is below the minimal thrombotic dose of 3ng/mg observed in an in vivo model. Relative label-free quantitation highlighted significant differences in normalized abundances of residual proteins between Ig products. A TEE-positive batch was distinguished by unique profile of residual proteins, including FXIa but also various blood stream-regulator proteins (fibrinogen, angiotensinogen, antithrombin-III, complement component C8, …). Those results emphasize that MS screening is a relevant first-line test to prevent any undesired concentration of plasma impurities after a plasma pool or manufacturing process change. Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.

  17. Quantitative determination of fenoterol and fenoterol derivatives in rat plasma using on-line immunoextraction and liquid chromatography/mass spectrometry.

    PubMed

    Kim, Hee Seung; Siluk, Danuta; Wainer, Irving W

    2009-04-17

    An on-line immunoextraction and liquid chromatography/mass spectrometry (LC/MS) method was developed and validated for the determination of R,R'-fenoterol, R,R'-methoxyfenoterol and R,S'-naphthylfenoterol in rat plasma. Sample preparation involved immunoextraction of analytes using an antibody raised against R,R'- and R,S'-aminofenoterol that was immobilized onto chromatographic support. LC was performed on a Waters hydrophilic interaction chromatography (HILIC) column (150 mm x 2.1mm), using an isocratic mobile phase of methanol:ammonium acetate (10mM, pH 6.8) (90:10, v/v) at a flow rate of 0.2 ml/min. The MS was operated in the single ion monitoring mode (m/z 304.2 for R,R'-fenoterol, m/z 318.1 for R,R'-methoxyfenoterol, and m/z 339.2 for R,S'-naphthylfenoterol). Optimization of analytes desorption process from the immunoextraction column was performed by factorial analysis and the sample calibration curves were made with spiked rat plasma samples containing 0.5-100 ng/ml of drugs. The cross-selectivity studies of the antibody were determined and the results suggested high selectivities toward R,R'-fenoterol, R,R'-methoxyfenoterol and R,S'-naphthylfenoterol. The accuracy of assay was more than 96% while intra- and inter-day precision of assay were less than 12.4%. Stability studies (2h benchtop, freeze/thaw, and autosampler stability) were conducted and the analytes were stable through out studies. The validated method was used to determine the plasma concentration-time profiles of drugs after oral administration to rats of R,R'-fenoterol, R,R'-methoxyfenoterol and R,S'-naphthylfenoterol.

  18. Quantitative determination of fenoterol and fenoterol derivatives in rat plasma using on-line immunoextraction and liquid chromatography/mass spectrometry

    PubMed Central

    Kim, Hee Seung; Siluk, Danuta; Wainer, Irving W.

    2008-01-01

    An on-line immunoextraction and liquid chromatography/mass spectrometry (LC/MS) method was developed and validated for the determination of R,R′-fenoterol, R,R′-methoxyfenoterol and R,S′-naphthylfenoterol in rat plasma. Sample preparation involved immunoextraction of analytes using an antibody raised against R,R′- and R,S′-aminofenoterol that was immobilized onto chromatographic support. LC was performed on a Waters hydrophilic interaction chromatography (HILIC) column (150 mm × 2.1 mm), using an isocratic mobile phase of methanol:ammonium acetate (10 mM, pH 6.8) (90:10, v/v) at a flow rate of 0.2 ml/min. The MS was operated in the single ion monitoring mode (m/z 304.2 for R,R′-fenoterol, m/z 318.1 for R,R′-methoxyfenoterol, and m/z 339.2 for R,S′-naphthylfenoterol). Optimization of analytes desorption process from the immunoextraction column was performed by factorial analysis and the sample calibration curves were made with spiked rat plasma samples containing 0.5−100 ng/ml of drugs. The cross-selectivity studies of the antibody were determined and the results suggested high selectivities toward R,R′-fenoterol, R,R′-methoxyfenoterol and R,S′-naphthylfenoterol. The accuracy of assay was more than 96% while intra- and inter-day precision of assay were less than 12.4%. Stability studies (2 h benchtop, freeze/thaw, and autosampler stability) were conducted and the analytes were stable through out studies. The validated method was used to determine the plasma concentration–time profiles of drugs after oral administration to rats of R,R′-fenoterol, R,R′-methoxyfenoterol and R,S′-naphthylfenoterol. PMID:18778830

  19. Increased interleukin-11 levels in thoracic aorta and plasma from patients with acute thoracic aortic dissection.

    PubMed

    Xu, Yao; Ye, Jing; Wang, Menglong; Wang, Yuan; Ji, Qingwei; Huang, Ying; Zeng, Tao; Wang, Zhen; Ye, Di; Jiang, Huimin; Liu, Jianfang; Lin, Yingzhong; Wan, Jun

    2018-06-01

    Interleukin (IL) 11 is closely related to tumor and hematological system diseases. Recent studies have demonstrated that IL-11 also participates in cardiovascular diseases, including ischemia-reperfusion mediated heart injury and acute myocardial infarction. This study aimed to investigate whether IL-11 is involved in acute thoracic aortic dissection (TAD). Aortic tissue samples from normal donors and acute TAD patients were collected, and the expression of IL-11 in all aortic tissue was analyzed. In addition, blood samples from patients with chest pain were collected and divided into a non-AD (NAD) group and a TAD group according to the results of computed tomography angiography of the thoracic aorta. The plasma IL-11, IL-17 and interferon (IFN) γ in all blood samples were measured. Compared with aortic tissue of normal controls, IL-11 was significantly increased in aortic tissue of acute TAD patients, especially in the torn section. The IL-11 was derived from aorta macrophages in TAD. In addition, the plasma IL-11, IL-17 and IFN-γ were significantly higher in acute TAD patients than in NAD patients, and the correlation analysis showed that IL-11 levels were positively correlated with levels of IFN-γ, IL-17, glucose, systolic blood pressure, diastolic blood pressure, white blood cells, C-reactive proteins and D-dimers. Binary logistic regression analyses showed that elevated IL11 in patients who may have diagnostic value of TAD, but less that D-dimer. IL-11 was increased in thoracic aorta and plasma of TAD patients and may be a promising biomarker for diagnosis in patients with TAD. Copyright © 2018. Published by Elsevier B.V.

  20. IL8 and IL16 levels indicate serum and plasma quality.

    PubMed

    Kofanova, Olga; Henry, Estelle; Quesada, Rocio Aguilar; Bulla, Alexandre; Linares, Hector Navarro; Lescuyer, Pierre; Shea, Kathi; Stone, Mars; Tybring, Gunnel; Bellora, Camille; Betsou, Fay

    2018-02-09

    Longer pre-centrifugation times alter the quality of serum and plasma samples. Markers for such delays in sample processing and hence for the sample quality, have been identified. Twenty cytokines in serum, EDTA plasma and citrate plasma samples were screened for changes in concentration induced by extended blood pre-centrifugation delays at room temperature. The two cytokines that showed the largest changes were further validated for their "diagnostic performance" in identifying serum or plasma samples with extended pre-centrifugation times. In this study, using R&D Systems ELISA kits, EDTA plasma samples and serum samples with a pre-centrifugation delay longer than 24 h had an IL16 concentration higher than 313 pg/mL, and an IL8 concentration higher than 125 pg/mL, respectively. EDTA plasma samples with a pre-centrifugation delay longer than 48 h had an IL16 concentration higher than 897 pg/mL, citrate plasma samples had an IL8 concentration higher than 21.5 pg/mL and serum samples had an IL8 concentration higher than 528 pg/mL. These robust and accurate tools, based on simple and commercially available ELISA assays can greatly facilitate qualification of serum and plasma legacy collections with undocumented pre-analytics.

  1. Public expenditure for plasma-derived and recombinant medicinal products in Italy.

    PubMed

    Lanzoni, Monica; Candura, Fabio; Calizzani, Gabriele; Biffoli, Claudia; Grazzini, Giuliano

    2013-09-01

    In Italy, the supply of plasma-derived medicinal products funded by the National Health Service can be through public healthcare facilities, accredited pharmacies or toll fractionation agreements between Regions and the manufacturer. Pharmaceutical public expenditure includes the supply related to the first two channels and costs can significantly vary because of channel-specific price reductions. This paper describes 2011 public expenditure for plasma-derived medicinal products purchased on the market, as well as the cost analysis per active substance. Analysis of the usage of plasma-derived medicinal products and of the related expenditure in public facilities has been carried out using medicinal product traceability data. The analysis related to the accredited pharmacies channel has been carried out using quantities for every medicinal package recorded by Pharmacy Associations and applying reference prices in force on March 1(st), 2012 as well as discounts for the accredited pharmaceutical expenditure imposed by law. At national and regional level, total and total per capita expenditures on plasma-derived medicinal products by market channel and funded by the National Health Service are shown. Analysis was conducted considering the active substances in three groups: substances included in toll fractionation agreements, recombinant coagulation factors, and other substances not included in toll fractionation agreements. In 2011, the national expenditure estimate for plasma-derived and recombinant medicinal product acquisition on the market was about € 535 million. The purchased volumes and mean purchased prices per unit of each substance have a significant influence on the observed regional variability of the pharmaceutical public expenditure. A strategy of regional comparison aimed at both sharing a national range of reference for purchase prices and evaluating modalities for centralised purchasing is desirable.

  2. Autoxidation products of both carbohydrates and lipids are increased in uremic plasma: is there oxidative stress in uremia?

    PubMed

    Miyata, T; Fu, M X; Kurokawa, K; van Ypersele de Strihou, C; Thorpe, S R; Baynes, J W

    1998-10-01

    Advanced glycation end products (AGEs), formed by non-enzymatic glycation and oxidation (glycoxidation) reactions, have been implicated in the pathogenesis of several diseases, including normoglycemic uremia. AGE research in uremia has focused on the accumulation of carbohydrate-derived adducts generated by the Maillard reaction. Recent studies, however, have demonstrated that one AGE, the glycoxidation product carboxymethyllysine (CML), could be derived not only from carbohydrates but also from oxidation of polyunsaturated fatty acids in vitro, raising the possibility that both carbohydrate and lipid autoxidation might be increased in uremia. To address this hypothesis, we applied gas chromatography-mass spectrometry and high performance liquid chromatography to measure protein adducts formed in uremic plasma by reactions between carbonyl compounds and protein amino groups: pentosidine derived from carbohydrate-derived carbonyls, malondialdehyde (MDA)-lysine derived from lipid-derived carbonyls, and CML originating possibly from both sources. All three adducts were elevated in uremic plasma. Plasma CML levels were mainly (>95%) albumin bound. Their levels were not correlated with fructoselysine levels and were similar in diabetic and non-diabetic patients on hemodialysis, indicating that their increase was not driven by glucose. Pentosidine and MDA-lysine were also increased in plasma to the same extent in diabetic and non-diabetic hemodialysis patients. Statistical analysis indicated that plasma levels of CML correlated weakly (P < 0.05) with those of pentosidine and MDA-lysine, but that pentosidine and MDA-lysine varied independently (P > 0.5). These data suggest that the increased levels of AGEs in blood, and probably in tissues, reported in uremia implicate a broad derangement in non-enzymatic biochemistry involving alterations in autoxidation of both carbohydrates and lipids.

  3. Plasma exosome microRNAs are indicative of breast cancer.

    PubMed

    Hannafon, Bethany N; Trigoso, Yvonne D; Calloway, Cameron L; Zhao, Y Daniel; Lum, David H; Welm, Alana L; Zhao, Zhizhuang J; Blick, Kenneth E; Dooley, William C; Ding, W Q

    2016-09-08

    microRNAs are promising candidate breast cancer biomarkers due to their cancer-specific expression profiles. However, efforts to develop circulating breast cancer biomarkers are challenged by the heterogeneity of microRNAs in the blood. To overcome this challenge, we aimed to develop a molecular profile of microRNAs specifically secreted from breast cancer cells. Our first step towards this direction relates to capturing and analyzing the contents of exosomes, which are small secretory vesicles that selectively encapsulate microRNAs indicative of their cell of origin. To our knowledge, circulating exosome microRNAs have not been well-evaluated as biomarkers for breast cancer diagnosis or monitoring. Exosomes were collected from the conditioned media of human breast cancer cell lines, mouse plasma of patient-derived orthotopic xenograft models (PDX), and human plasma samples. Exosomes were verified by electron microscopy, nanoparticle tracking analysis, and western blot. Cellular and exosome microRNAs from breast cancer cell lines were profiled by next-generation small RNA sequencing. Plasma exosome microRNA expression was analyzed by qRT-PCR analysis. Small RNA sequencing and qRT-PCR analysis showed that several microRNAs are selectively encapsulated or highly enriched in breast cancer exosomes. Importantly, the selectively enriched exosome microRNA, human miR-1246, was detected at significantly higher levels in exosomes isolated from PDX mouse plasma, indicating that tumor exosome microRNAs are released into the circulation and can serve as plasma biomarkers for breast cancer. This observation was extended to human plasma samples where miR-1246 and miR-21 were detected at significantly higher levels in the plasma exosomes of 16 patients with breast cancer as compared to the plasma exosomes of healthy control subjects. Receiver operating characteristic curve analysis indicated that the combination of plasma exosome miR-1246 and miR-21 is a better indicator of breast cancer than their individual levels. Our results demonstrate that certain microRNA species, such as miR-21 and miR-1246, are selectively enriched in human breast cancer exosomes and significantly elevated in the plasma of patients with breast cancer. These findings indicate a potential new strategy to selectively analyze plasma breast cancer microRNAs indicative of the presence of breast cancer.

  4. TaqMan 5′-Nuclease Human Immunodeficiency Virus Type 1 PCR Assay with Phage-Packaged Competitive Internal Control for High-Throughput Blood Donor Screening

    PubMed Central

    Drosten, C.; Seifried, E.; Roth, W. K.

    2001-01-01

    Screening of blood donors for human immunodeficiency virus type 1 (HIV-1) infection by PCR permits the earlier diagnosis of HIV-1 infection compared with that by serologic assays. We have established a high-throughput reverse transcription (RT)-PCR assay based on 5′-nuclease PCR. By in-tube detection of HIV-1 RNA with a fluorogenic probe, the 5′-nuclease PCR technology (TaqMan PCR) eliminates the risk of carryover contamination, a major problem in PCR testing. We outline the development and evaluation of the PCR assay from a technical point of view. A one-step RT-PCR that targets the gag genes of all known HIV-1 group M isolates was developed. An internal control RNA detectable with a heterologous 5′-nuclease probe was derived from the viral target cDNA and was packaged into MS2 coliphages (Armored RNA). Because the RNA was protected against digestion with RNase, it could be spiked into patient plasma to control the complete sample preparation and amplification process. The assay detected 831 HIV-1 type B genome equivalents per ml of native plasma (95% confidence interval [CI], 759 to 936 HIV-1 B genome equivalents per ml) with a ≥95% probability of a positive result, as determined by probit regression analysis. A detection limit of 1,195 genome equivalents per ml of (individual) donor plasma (95% CI, 1,014 to 1,470 genome equivalents per ml of plasma pooled from individuals) was achieved when 96 samples were pooled and enriched by centrifugation. Up to 4,000 plasma samples per PCR run were tested in a 3-month trial period. Although data from the present pilot feasibility study will have to be complemented by a large clinical validation study, the assay is a promising approach to the high-throughput screening of blood donors and is the first noncommercial test for high-throughput screening for HIV-1. PMID:11724836

  5. Determination of glycated albumin using boronic acid-derived agarose beads on paper-based devices.

    PubMed

    Ko, Euna; Tran, Van-Khue; Geng, Yanfang; Kim, Min Ki; Jin, Ga Hyun; Son, Seong Eun; Hur, Won; Seong, Gi Hun

    2018-01-01

    Self-monitoring of glycated albumin (GA), a useful glycemic marker, is an established method for preventing diabetes complications. Here, the paper-based lateral flow assay devices were developed for the sensitive detection of GA and the total human serum albumin (tHSA) in self-monitoring diabetes patients. Boronic acid-derived agarose beads were packed into a hole on a lateral flow channel. These well-coordinated agarose beads were used to capture GA through specific cis-diol interactions and to enhance the colorimetric signals by concentrating the target molecules. The devices exhibited large dynamic ranges (from 10  μ g/ml to 10 mg/ml for GA and from 10 mg/ml to 50 mg/ml for tHSA) and low detection limits (7.1  μ g/ml for GA and 4.7 mg/ml for tHSA), which cover the range of GA concentration in healthy plasma, which is 0.21-1.65 mg/ml (0.6%-3%). In determining the unknown GA concentrations in two commercial human plasma samples, the relative percentage difference between the values found by a standard ELISA kit and those found by our developed devices was 2.62% and 8.80%, which are within an acceptable range. The measurements of GA and tHSA were completed within 20 min for the total sample-to-answer diagnosis, fulfilling the demand for rapid analysis. Furthermore, the recovery values ranged from 99.4% to 110% in device accuracy tests. These results indicate that the developed paper-based device with boronic acid-derived agarose beads is a promising platform for GA and tHSA detection as applied to self-monitoring systems.

  6. Immunoassays for scarce tumour-antigens in exosomes: detection of the human NKG2D-Ligand, MICA, in tetraspanin-containing nanovesicles from melanoma.

    PubMed

    López-Cobo, Sheila; Campos-Silva, Carmen; Moyano, Amanda; Oliveira-Rodríguez, Myriam; Paschen, Annette; Yáñez-Mó, María; Blanco-López, María Carmen; Valés-Gómez, Mar

    2018-05-02

    Tumour-derived exosomes can be released to serum and provide information on the features of the malignancy, however, in order to perform systematic studies in biological samples, faster diagnostic techniques are needed, especially for detection of low abundance proteins. Most human cancer cells are positive for at least one ligand for the activating immune receptor NKG2D and the presence in plasma of NKG2D-ligands can be associated with prognosis. Using MICA as example of a tumour-derived antigen, endogenously expressed in metastatic melanoma and recruited to exosomes, we have developed two immunocapture-based assays for detection of different epitopes in nanovesicles. Although both techniques, enzyme-linked immunosorbent assay (ELISA) and Lateral flow immunoassays (LFIA) have the same theoretical basis, that is, using capture and detection antibodies for a colorimetric read-out, analysis of exosome-bound proteins poses methodological problems that do not occur when these techniques are used for detection of soluble molecules, due to the presence of multiple epitopes on the vesicle. Here we demonstrate that, in ELISA, the signal obtained was directly proportional to the amount of epitopes per exosome. In LFIA, the amount of detection antibody immobilized in Au-nanoparticles needs to be low for efficient detection, otherwise steric hindrance results in lower signal. We describe the conditions for detection of MICA in exosomes and prove, for the first time using both techniques, the co-existence in one vesicle of exosomal markers (the tetraspanins CD9, CD63 and CD81) and an endogenously expressed tumour-derived antigen. The study also reveals that scarce proteins can be used as targets for detection antibody in LFIA with a better result than very abundant proteins and that the conditions can be optimized for detection of the protein in plasma. These results open the possibility of analyzing biological samples for the presence of tumour-derived exosomes using high throughput techniques.

  7. Preparation and Immunoaffinity Depletion of Fresh Frozen Tissue Homogenates for Mass Spectrometry-Based Proteomics in the Context of Drug Target/Biomarker Discovery.

    PubMed

    Prieto, DaRue A; Chan, King C; Johann, Donald J; Ye, Xiaoying; Whitely, Gordon; Blonder, Josip

    2017-01-01

    The discovery of novel drug targets and biomarkers via mass spectrometry (MS)-based proteomic analysis of clinical specimens has proven to be challenging. The wide dynamic range of protein concentration in clinical specimens and the high background/noise originating from highly abundant proteins in tissue homogenates and serum/plasma encompass two major analytical obstacles. Immunoaffinity depletion of highly abundant blood-derived proteins from serum/plasma is a well-established approach adopted by numerous researchers; however, the utilization of this technique for immunodepletion of tissue homogenates obtained from fresh frozen clinical specimens is lacking. We first developed immunoaffinity depletion of highly abundant blood-derived proteins from tissue homogenates, using renal cell carcinoma as a model disease, and followed this study by applying it to different tissue types. Tissue homogenate immunoaffinity depletion of highly abundant proteins may be equally important as is the recognized need for depletion of serum/plasma, enabling more sensitive MS-based discovery of novel drug targets, and/or clinical biomarkers from complex clinical samples. Provided is a detailed protocol designed to guide the researcher through the preparation and immunoaffinity depletion of fresh frozen tissue homogenates for two-dimensional liquid chromatography, tandem mass spectrometry (2D-LC-MS/MS)-based molecular profiling of tissue specimens in the context of drug target and/or biomarker discovery.

  8. Differential effects of EPA versus DHA on postprandial vascular function and the plasma oxylipin profile in men.

    PubMed

    McManus, Seán; Tejera, Noemi; Awwad, Khader; Vauzour, David; Rigby, Neil; Fleming, Ingrid; Cassidy, Aedin; Minihane, Anne Marie

    2016-09-01

    Our objective was to investigate the impact of EPA versus DHA on arterial stiffness and reactivity and underlying mechanisms (with a focus on plasma oxylipins) in the postprandial state. In a three-arm crossover acute test meal trial, men (n = 26, 35-55 years) at increased CVD risk received a high-fat (42.4 g) test meal providing 4.16 g of EPA or DHA or control oil in random order. At 0 h and 4 h, blood samples were collected to quantify plasma fatty acids, long chain n-3 PUFA-derived oxylipins, nitrite and hydrogen sulfide, and serum lipids and glucose. Vascular function was assessed using blood pressure, reactive hyperemia index, pulse wave velocity, and augmentation index (AIx). The DHA-rich oil significantly reduced AIx by 13% (P = 0.047) with the decrease following EPA-rich oil intervention not reaching statistical significance. Both interventions increased EPA- and DHA-derived oxylipins in the acute postprandial state, with an (1.3-fold) increase in 19,20-dihydroxydocosapentaenoic acid evident after DHA intervention (P < 0.001). In conclusion, a single dose of DHA significantly improved postprandial arterial stiffness as assessed by AIx, which if sustained would be associated with a significant decrease in CVD risk. The observed increases in oxylipins provide a mechanistic insight into the AIx effect. Copyright © 2016 by the American Society for Biochemistry and Molecular Biology, Inc.

  9. Metabolomic Fingerprinting in Various Body Fluids of a Diet-Controlled Clinical Smoking Cessation Study Using a Validated GC-TOF-MS Metabolomics Platform.

    PubMed

    Goettel, Michael; Niessner, Reinhard; Mueller, Daniel; Scherer, Max; Scherer, Gerhard; Pluym, Nikola

    2017-10-06

    Untargeted GC-TOF-MS analysis proved to be a suitable analytical platform to determine alterations in the metabolic profile. Several metabolic pathways were found to be altered in a first clinical study comparing smokers against nonsmokers. Subsequently, we conducted a clinical diet-controlled study to investigate alterations in the metabolic profile during the course of 3 months of smoking cessation. Sixty male subjects were included in the study, and plasma, saliva, and urine samples were collected during four 24 h stationary visits: at baseline, while still smoking, after 1 week, after 1 month, and after 3 months of cessation. Additionally, subjects were monitored for their compliance by measurements of CO in exhaled breath and salivary cotinine throughout the study. GC-TOF-MS fingerprinting was applied to plasma, saliva, and urine samples derived from 39 compliant subjects. In total, 52 metabolites were found to be significantly altered including 26 in plasma, 20 in saliva, and 12 in urine, respectively. In agreement with a previous study comparing smokers and nonsmokers, the fatty acid and amino acid metabolism showed significant alterations upon 3 months of smoking cessation. Thus these results may indicate a partial recovery of metabolic pathway perturbations, even after a relatively short period of smoking cessation.

  10. Longitudinal Analysis of Cerebrospinal Fluid and Plasma HIV-1 Envelope Sequences Isolated From a Single Donor with HIV Asymptomatic Neurocognitive Impairment.

    PubMed

    Vázquez-Santiago, Fabián; García, Yashira; Rivera-Román, Ivelisse; Noel, Richard J; Wojna, Valerie; Meléndez, Loyda M; Rivera-Amill, Vanessa

    Combined antiretroviral treatment (cART) has changed the clinical presentation of HIV-associated neurocognitive disorders (HAND) to that of the milder forms of the disease. Asymptomatic neurocognitive impairment (ANI) is now more prevalent and is associated with increased morbidity and mortality risk in HIV-1-infected people. HIV-1 envelope ( env ) genetic heterogeneity has been detected within the central nervous system (CNS) of individuals with ANI. Changes within env determine co-receptor use, cellular tropism, and neuropathogenesis. We hypothesize that compartmental changes are associated with HIV-1 env C2V4 during ANI and sought to analyze paired HIV-1 env sequences from plasma and cerebrospinal fluid (CSF) of a female subject undergoing long-term cART. Paired plasma and CSF samples were collected at 12-month intervals and HIV-1 env C2V4 was cloned and sequenced. Phylogenetic analysis of paired samples consistently showed genetic variants unique to the CSF. Phenotypic prediction showed CCR5 (R5) variants for all CSF-derived sequences and showed minor X4 variants (or dual-tropic) in the plasma at later time points. Viral compartmentalization was evident throughout the study, suggesting that the occurrence of distinctive env strains may contribute to the neuropathogenesis of HAND. Our study provides new insights about the genetic characteristics within the C2V4 of HIV-1 env that persist after long-term cART and during the course of persistent ANI.

  11. Durable engraftment of genetically modified FVIII-secreting autologous bone marrow stromal cells in the intramedullary microenvironment.

    PubMed

    Lee, Sze Sing; Sivalingam, Jaichandran; Nirmal, Ajit J; Ng, Wai Har; Kee, Irene; Song, In Chin; Kiong, Chin Yong; Gales, Kristoffer A; Chua, Frederic; Pena, Edgar M; Ogden, Bryan E; Kon, Oi Lian

    2018-04-23

    Genetically modified FVIII-expressing autologous bone marrow-derived mesenchymal stromal cells (BMSCs) could cure haemophilia A. However, culture-expanded BMSCs engraft poorly in extramedullary sites. Here, we compared the intramedullary cavity, skeletal muscle, subcutaneous tissue and systemic circulation as tissue microenvironments that could support durable engraftment of FVIII-secreting BMSC in vivo. A zinc finger nuclease integrated human FVIII transgene into PPP1R12C (intron 1) of culture-expanded primary canine BMSCs. FVIII-secretory capacity of implanted BMSCs in each dog was expressed as an individualized therapy index (number of viable BMSCs implanted × FVIII activity secreted/million BMSCs/24 hours). Plasma samples before and after implantation were assayed for transgenic FVIII protein using an anti-human FVIII antibody having negligible cross-reactivity with canine FVIII. Plasma transgenic FVIII persisted for at least 48 weeks after implantation in the intramedullary cavity. Transgenic FVIII protein levels were low after intramuscular implantation and undetectable after both intravenous infusion and subcutaneous implantation. All plasma samples were negative for anti-human FVIII antibodies. Plasma concentrations and durability of transgenic FVIII secretion showed no correlation with the therapy index. Thus, the implantation site microenvironment is crucial. The intramedullary microenvironment, but not extramedullary tissues, supported durable engraftment of genetically modified autologous FVIII-secreting BMSCs. © 2018 National Cancer Centre of Singapore Pte Ltd. Journal of Cellular and Molecular Medicine published by John Wiley & Sons Ltd and Foundation for Cellular and Molecular Medicine.

  12. A comparison of serum and plasma cytokine values using a multiplexed assay in cats.

    PubMed

    Gruen, Margaret E; Messenger, Kristen M; Thomson, Andrea E; Griffith, Emily H; Paradise, Hayley; Vaden, Shelly; Lascelles, B D X

    2016-12-01

    Degenerative joint disease (DJD) is highly prevalent in cats, and pain contributes to morbidity. In humans, alterations of cytokine concentrations have been associated with joint deterioration and pain. Similar changes have not been investigated in cats. Cytokine concentrations can be measured using multiplex technology with small samples of serum or plasma, however, serum and plasma are not interchangeable for most bioassays. Correlations for cytokine concentrations between serum and plasma have not been evaluated in cats. To evaluate the levels of detection and agreement between serum and plasma samples in cats. Paired serum and plasma samples obtained from 38 cats. Blood was collected into anti-coagulant free and EDTA Vacutainer ® tubes, serum or plasma extracted, and samples frozen at -80°C until testing. Duplicate samples were tested using a 19-plex feline cytokine/chemokine magnetic bead panel. Agreement between serum and plasma for many analytes was high, however correlation coefficients ranged from -0.01 to 0.97. Results from >50% of samples were below the lower limit of quantification for both serum and plasma for nine analytes, and for an additional three analytes for plasma only. While serum and plasma agreement was generally good, detection was improved using serum samples. Copyright © 2016 Elsevier B.V. All rights reserved.

  13. Development and validation of a high throughput assay for the quantification of multiple green tea-derived catechins in human plasma.

    PubMed

    Mawson, Deborah H; Jeffrey, Keon L; Teale, Philip; Grace, Philip B

    2018-06-19

    A rapid, accurate and robust method for the determination of catechin (C), epicatechin (EC), gallocatechin (GC), epigallocatechin (EGC), catechin gallate (Cg), epicatechin gallate (ECg), gallocatechin gallate (GCg) and epigallocatechin gallate (EGCg) concentrations in human plasma has been developed. The method utilises protein precipitation following enzyme hydrolysis, with chromatographic separation and detection using reversed-phase liquid chromatography - tandem mass spectrometry (LC-MS/MS). Traditional issues such as lengthy chromatographic run times, sample and extract stability, and lack of suitable internal standards have been addressed. The method has been evaluated using a comprehensive validation procedure, confirming linearity over appropriate concentration ranges, and inter/intra batch precision and accuracies within suitable thresholds (precisions within 13.8% and accuracies within 12.4%). Recoveries of analytes were found to be consistent between different matrix samples, compensated for using suitable internal markers and within the performance of the instrumentation used. Similarly, chromatographic interferences have been corrected using the internal markers selected. Stability of all analytes in matrix is demonstrated over 32 days and throughout extraction conditions. This method is suitable for high throughput sample analysis studies. This article is protected by copyright. All rights reserved.

  14. The Study of Al0.29Ga0.71N-BASED Schottky Photodiodes Grown on Silicon by Plasma-Assisted Molecular Beam Epitaxy

    NASA Astrophysics Data System (ADS)

    Mohd Yusoff, M. Z.; Hassan, Z.; Chin, C. W.; Hassan, H. Abu; Abdullah, M. J.; Mohammad, N. N.; Ahmad, M. A.; Yusof, Y.

    2013-05-01

    In this paper, the growth and characterization of epitaxial Al0.29Ga0.71N grown on Si(111) by RF-plasma assisted molecular beam epitaxy (MBE) are described. The Al mole fraction was derived from the HR-XRD symmetric rocking curve (RC) ω/2θ scans of (0002) plane as x = 0.29. PL spectrum of sample has shown sharp and intense band edge emission of GaN without the existence of yellow emission band, showing that it is comparable in crystal quality of the sample when compared with previous reports. From the Raman measurement of as-grown Al0.29Ga0.71N layer on GaN/AlN/Si sample. We found that the dominant E2 (high) phonon mode of GaN appears at 572.7 cm-1. The E2 (high) mode of AlN appears at 656.7 cm-1 and deviates from the standard value of 655 cm-1 for unstrained AlN. Finally, AlGaN Schottky photodiode have been fabricated and analyzed by mean of electrical characterization, using current-voltage (I-V) measurement to evaluate the performance of this device.

  15. Analysis of 4-methylthioamphetamine in clinical specimens.

    PubMed

    Elliott, S P

    2001-07-01

    There has been much publicity, particularly in Europe, regarding a new phenylethylamine-based compound called 4-methylthioamphetamine (4-MTA), also known as para-methylthioamphetamine (p-MTA), MTA or 'Flatliner'. Chemically, 4-MTA is an amphetamine derivative and is a potent, non-neurotoxic serotonin-releasing agent and reversible inhibitor of rat monoamine oxidase-A. Its effects, therefore, appear different from those of amphetamine. Analysis of various plasma and urine specimens in three clinical cases implicating 'Ecstasy' ingestion revealed the presence of 4-MTA. Presumed metabolites were also detected, with one compound identified as being 4-MTA sulphoxide. The concentrations of 4-MTA measured in the plasma ranged from 0.131 mg/L to 0.760 mg/L. In one patient the 4-MTA concentration was determined in a series of plasma samples and this allowed a presumptive half-life of approximately 7 h to be estimated. This paper describes the first reported data regarding possible pharmacokinetics of 4-MTA in humans and presents the first reported non-fatal instances of 4-MTA intoxication in the UK.

  16. Quantitation of silibinin, a putative cancer chemopreventive agent derived from milk thistle (Silybum marianum), in human plasma by high-performance liquid chromatography and identification of possible metabolites.

    PubMed

    Hoh, Carmen S L; Boocock, David J; Marczylo, Timothy H; Brown, V A; Cai, Hong; Steward, William P; Berry, David P; Gescher, Andreas J

    2007-04-04

    Silibinin has recently received attention as a potential cancer chemopreventive agent because of its antiproliferative and anticarcinogenic effects. A simple and specific reversed-phase high-performance liquid chromatography method was developed and validated for the quantitation of silibinin in human plasma. Sample preparation involved simple protein precipitation, and separation was achieved on a Waters Atlantis C18 column with flow rate of 1.0 mL/min at 40 degrees C and UV detection at 290 nm. Silibinin was detected as two peaks corresponding to trans-diastereoisomers. The peak area was linear over the investigated concentration range (0-5000 ng/mL). The limits of detection were 2 and 1 ng/mL for the two diastereoisomers (d1 and d2), with a recovery of 53-58%. This method was utilized to detect silibinin in plasma of colorectal patients after 7 days of treatment with silipide (silibinin formulated with phosphatidyl choline).

  17. Measurement of fetal fraction in cell-free DNA from maternal plasma using a panel of insertion/deletion polymorphisms.

    PubMed

    Barrett, Angela N; Xiong, Li; Tan, Tuan Z; Advani, Henna V; Hua, Rui; Laureano-Asibal, Cecille; Soong, Richie; Biswas, Arijit; Nagarajan, Niranjan; Choolani, Mahesh

    2017-01-01

    Cell-free DNA from maternal plasma can be used for non-invasive prenatal testing for aneuploidies and single gene disorders, and also has applications as a biomarker for monitoring high-risk pregnancies, such as those at risk of pre-eclampsia. On average, the fractional cell-free fetal DNA concentration in plasma is approximately 15%, but can vary from less than 4% to greater than 30%. Although quantification of cell-free fetal DNA is straightforward in the case of a male fetus, there is no universal fetal marker; in a female fetus measurement is more challenging. We have developed a panel of multiplexed insertion/deletion polymorphisms that can measure fetal fraction in all pregnancies in a simple, targeted sequencing reaction. A multiplex panel of primers was designed for 35 indels plus a ZFX/ZFY amplicon. cfDNA was extracted from plasma from 157 pregnant women, and maternal genomic DNA was extracted for 20 of these samples for panel validation. Sixty-one samples from pregnancies with a male fetus were subjected to whole genome sequencing on the Ion Proton sequencing platform, and fetal fraction derived from Y chromosome counts was compared to fetal fraction measured using the indel panel. A total of 157 cell-free DNA samples were sequenced using the indel panel, and informativity was assessed, along with the proportion of fetal DNA. Using gDNA we optimised the indel panel, removing amplicons giving rise to PCR bias. Good correlation was found between fetal fraction using indels and using whole genome sequencing of the Y chromosome (Spearmans r = 0.69). A median of 12 indels were informative per sample. The indel panel was informative in 157/157 cases (mean fetal fraction 14.4% (±0.58%)). Using our targeted next generation sequencing panel we can readily assess the fetal DNA percentage in male and female pregnancies.

  18. Measurement of fetal fraction in cell-free DNA from maternal plasma using a panel of insertion/deletion polymorphisms

    PubMed Central

    Xiong, Li; Tan, Tuan Z.; Advani, Henna V.; Hua, Rui; Laureano-Asibal, Cecille; Soong, Richie; Biswas, Arijit; Nagarajan, Niranjan; Choolani, Mahesh

    2017-01-01

    Objective Cell-free DNA from maternal plasma can be used for non-invasive prenatal testing for aneuploidies and single gene disorders, and also has applications as a biomarker for monitoring high-risk pregnancies, such as those at risk of pre-eclampsia. On average, the fractional cell-free fetal DNA concentration in plasma is approximately 15%, but can vary from less than 4% to greater than 30%. Although quantification of cell-free fetal DNA is straightforward in the case of a male fetus, there is no universal fetal marker; in a female fetus measurement is more challenging. We have developed a panel of multiplexed insertion/deletion polymorphisms that can measure fetal fraction in all pregnancies in a simple, targeted sequencing reaction. Methods A multiplex panel of primers was designed for 35 indels plus a ZFX/ZFY amplicon. cfDNA was extracted from plasma from 157 pregnant women, and maternal genomic DNA was extracted for 20 of these samples for panel validation. Sixty-one samples from pregnancies with a male fetus were subjected to whole genome sequencing on the Ion Proton sequencing platform, and fetal fraction derived from Y chromosome counts was compared to fetal fraction measured using the indel panel. A total of 157 cell-free DNA samples were sequenced using the indel panel, and informativity was assessed, along with the proportion of fetal DNA. Results Using gDNA we optimised the indel panel, removing amplicons giving rise to PCR bias. Good correlation was found between fetal fraction using indels and using whole genome sequencing of the Y chromosome (Spearmans r = 0.69). A median of 12 indels were informative per sample. The indel panel was informative in 157/157 cases (mean fetal fraction 14.4% (±0.58%)). Conclusions Using our targeted next generation sequencing panel we can readily assess the fetal DNA percentage in male and female pregnancies. PMID:29084245

  19. Survey of thermal plasma ions in Saturn's magnetosphere utilizing a forward model

    NASA Astrophysics Data System (ADS)

    Wilson, R. J.; Bagenal, F.; Persoon, A. M.

    2017-07-01

    The Cassini Plasma Spectrometer instrument gathered thermal ion data at Saturn from 2004 to 2012, predominantly observing water group ions and protons. Plasma parameters, with uncertainties, for those two ion species are derived using a forward model of anisotropic convected Maxwellians moving at a shared velocity. The resulting data set is filtered by various selection criteria to produce a survey of plasma parameters derived within 10° of the equator at radial distances of 5.5 to 30 RS (1 RS = Saturn's radius). The previous 2008 work used a simpler method and had just 150 records over 5 orbits; this comprehensive survey has 9736 records over all 9 years. We present the results of this survey and compare them with a previous survey derived from numerical moments, highlighting the differences between the reported densities and temperatures from the two methods. Radial profiles of the plasma parameters in the inner and middle magnetospheres out to ≈22RS are stable year by year, but variable at distances larger than 23 RS near the magnetopause. New results include proton densities increasing in the near magnetopause region, suggestive of plasma mixing; evidence for the global electric field in Saturn's inner magnetosphere extends out to ≈15RS; no evidence for supercorotating plasma nor the middle magnetosphere "plasma cam" feature is present; the thermal plasma β is found to exceed unity at equatorial distances greater than 15 RS.

  20. Pharmacokinetics of table and Port red wine anthocyanins: a crossover trial in healthy men.

    PubMed

    Fernandes, I; Marques, C; Évora, A; Cruz, L; de Freitas, V; Calhau, C; Faria, A; Mateus, N

    2017-05-24

    This study was designed to evaluate the pharmacokinetics of Port and table red wine anthocyanins in healthy men. Volunteers were recruited to drink 250 mL of a table red wine (221 mg of anthocyanins) and 150 mL of young Port red wine (49 mg of anthocyanins). Venous blood was collected from participants at 0, 15, 30, 60 and 120 min after wine ingestion. Urine samples were collected at baseline and at 120 min. Anthocyanins and anthocyanin metabolites in plasma and urine samples were quantified by HPLC-DAD and tentatively identified by LC-MS. Red wine anthocyanins were detected in their intact forms in both plasma and urine samples, but the glucuronylated metabolites of peonidin and malvidin (PnGlucr and MvGlucr) were the two main derivatives detected after both red wine consumptions. For the first time, and supported by the synthesis of Mv3Glucr, the main pathway followed by Mv3glc after absorption was described and involves anthocyanidin conjugation with glucuronic acid after glucose removal. Despite the lower total content of anthocyanins ingested when volunteers drank Port wine, no differences were observed in the plasma C max of MvGlucr and PnGlucr after table and Port red wine consumption. The relative bioavailability of anthocyanins in Port wine was 96.58 ± 5.74%, compared to the anthocyanins present in red wine. In conclusion, both Port and table red wines are good sources of bioavailable anthocyanins.

  1. High Resolution Mass Spectrometric Analysis of Secoiridoids and Metabolites as Biomarkers of Acute Olive Oil Intake-An Approach to Study Interindividual Variability in Humans.

    PubMed

    Silva, Sandra; Garcia-Aloy, Mar; Figueira, Maria Eduardo; Combet, Emilie; Mullen, William; Bronze, Maria Rosário

    2018-01-01

    Phenolic compounds are minor components of extra virgin olive oil (EVOO). Secoiridoids are the major components contributing to the phenolic content of EVOO. Information is lacking regarding their potential as biomarkers for EVOO intake. Healthy volunteers (n = 9) ingested 50 mL of EVOO in a single dose containing 322 mg kg -1 total phenolic content (caffeic acid equivalents) and 6 mg 20 g -1 hydroxytyrosol and its derivatives. Plasma is collected before (0 h) and at 0.5, 1, 2, 4, and 6 h after ingestion. Urine samples are collected prior to ingestion (0 h) and at 0-4, 4-8, 8-15, and 15-24 h. Samples are analyzed by UPLC coupled with an Exactive Orbitrap MS. Partial least squares discriminant analysis with orthogonal signal correction is applied to screen for metabolites that allow sample discrimination. Plasma biomarkers and urine biomarkers are selected although individual variability is observed among volunteers. Results are in accordance with in vitro experiments performed (in vitro digestion and hepatic microsomal activity assays). Plasma (elenolic acid + H 2 ; p-HPEA-EA + H 2 + glucuronide) and urinary (3,4-DHPEA-EA, 3,4-DHPEA-EA + H 2 +glucuronide, methyl 3,4-DHPEA-EA + H 2 +glucuronide) secoiridoid compounds are selected as biomarkers to monitor EVOO intake showing good predictive ability according to multivariate analysis. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  2. Detection of hepatitis B virus infection markers in dried plasma spots among patients in Congo-Brazzaville.

    PubMed

    Alidjinou, Enagnon Kazali; Moukassa, Donatien; Sané, Famara; Twagirimana Nyenyeli, Séraphin; Akoko, Estina Chandrelle; Mountou, Michèle Valy; Bocket, Laurence; Ibara, Jean-Rosaire; Hober, Didier

    2014-03-01

    The detection of hepatitis B virus (HBV) infection markers by using dried plasma spots from 32 patients living in Congo has been assessed. Considering frozen plasma samples as gold standard, the sensitivity and specificity of HBV serologic markers detection in dried plasma eluted from filter paper were 100%. The sensitivity and the specificity of HBV DNA detection reached 96% and 100%, respectively, with plasma samples dried on filter paper compared to standard samples. Dried plasma samples can represent an alternative to conventional sampling for HBV detection and management of the infection in developing countries. Copyright © 2014 Elsevier Inc. All rights reserved.

  3. Method for determining the concentration of atomic species in gases and solids

    DOEpatents

    Loge, G.W.

    1998-02-03

    Method is described for determining the concentration of atomic species in gases and solids. The method involves measurement of at least two emission intensities from a species in a sample that is excited by incident laser radiation. This generates a plasma therein after a sufficient time period has elapsed and during a second time period, permits an instantaneous temperature to be established within the sample. The concentration of the atomic species to be determined is then derived from the known emission intensity of a predetermined concentration of that species in the sample at the measured temperature, a quantity which is measured prior to the determination of the unknown concentration, and the actual measured emission from the unknown species, or by this latter emission and the emission intensity of a species having known concentration within the sample such as nitrogen for gaseous air samples. 4 figs.

  4. Activation Energy of Tantalum-Tungsten Oxide Thermite Reaction

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cervantes, O; Kuntz, J; Gash, A

    2010-02-25

    The activation energy of a high melting temperature sol-gel (SG) derived tantalum-tungsten oxide thermite composite was determined using the Kissinger isoconversion method. The SG derived powder was consolidated using the High Pressure Spark Plasma Sintering (HPSPS) technique to 300 and 400 C to produce pellets with dimensions of 5 mm diameter by 1.5 mm height. A custom built ignition setup was developed to measure ignition temperatures at high heating rates (500-2000 C {center_dot} min{sup -1}). Such heating rates were required in order to ignite the thermite composite. Unlike the 400 C samples, results show that the samples consolidated to 300more » C undergo an abrupt change in temperature response prior to ignition. This change in temperature response has been attributed to the crystallization of the amorphous WO{sub 3} in the SG derived Ta-WO{sub 3} thermite composite and not to a pre-ignition reaction between the constituents. Ignition temperatures for the Ta-WO{sub 3} thermite ranged from approximately 465-670 C. The activation energy of the SG derived Ta-WO{sup 3} thermite composite consolidated to 300 and 400 C were determined to be 37.787 {+-} 1.58 kJ {center_dot} mol{sup -1} and 57.381 {+-} 2.26 kJ {center_dot} mol{sup -1}, respectively.« less

  5. Components in Plasma-Derived Factor VIII, But Not in Recombinant Factor VIII Downregulate Anti-Inflammatory Surface Marker CD163 in Human Macrophages through Release of CXCL4 (Platelet Factor 4).

    PubMed

    Bertling, Anne; Brodde, Martin F; Visser, Mayken; Treffon, Janina; Fennen, Michelle; Fender, Anke C; Kelsch, Reinhard; Kehrel, Beate E

    2017-09-01

    Hemarthrosis, or bleeding into the joints, is a hallmark of hemophilia. Heme triggers oxidative stress, inflammation, and destruction of cartilage and bone. The haptoglobin-CD163-heme oxygenase-1 (HO-1) pathway circumvents heme toxicity through enzymatic degradation of heme and transcription of antioxidant genes. Plasma-derived factor concentrates contain many proteins that might impact on cellular pathways in joints, blood, and vessels. Activation of platelets from healthy volunteers was assessed by flow cytometry analysis of fibrinogen binding and CD62P expression. Platelet CXCL4 release was measured by ELISA. Human peripheral blood mononuclear cells were exposed to CXCL4 or platelet supernatants (untreated or pre-stimulated with factor VIII (FVIII) products) during their differentiation to macrophages and analyzed for CD163 expression. Some macrophage cultures were additionally incubated with autologous hemoglobin for 18 h for analysis of HO-1 expression. Platelet CXCL4 release was increased by all 8 tested plasma-derived FVIII products but not the 3 recombinant products. Macrophages exposed to supernatant from platelets treated with some plasma-derived FVIII products downregulated CD163 surface expression and failed to upregulate the athero- and joint protective enzyme HO-1 in response to hemoglobin. Plasma-derived FVIII products might promote bleeding-induced joint injury via generation of macrophages that are unable to counteract redox stress.

  6. Multiple vitellogenins and product yolk proteins in European sea bass (Dicentrarchus labrax): Molecular characterization, quantification in plasma, liver and ovary, and maturational proteolysis.

    PubMed

    Yilmaz, Ozlem; Prat, Francisco; Ibáñez, A Jose; Köksoy, Sadi; Amano, Haruna; Sullivan, Craig V

    2016-01-01

    Three complete vitellogenin (Vtg) polypeptides of European sea bass (Dicentrarchus labrax), an acanthomorph teleost spawning pelagic eggs in seawater, were deduced from cDNA and identified as VtgAa, VtgAb and VtgC based on current Vtg nomenclature and phylogeny. Label free quantitative mass spectrometry verified the presence of the three sea bass Vtgs or their product yolk proteins (YPs) in liver, plasma and ovary of postvitellogenic females. As evidenced by normalized spectral counts, VtgAb-derived protein was 2- to 5-fold more abundant, depending on sample type, than for VtgAa, while VtgC-derived protein was less abundant, albeit only 3-fold lower than for VtgAb in the ovary. Western blotting with Vtg type-specific antisera raised against corresponding gray mullet (Mugil cephalus) lipovitellins (Lvs) detected all three types of sea bass Vtg in the blood plasma of gravid females and/or estrogenized males and showed that all three forms of sea bass Lv undergo limited partial degradation during oocyte maturation. The comparatively high levels of VtgC-derived YPs in fully-grown oocytes and the maturational proteolysis of all three types of Lv differ from what has been reported for other teleosts spawning pelagic eggs in seawater but are similar to recent findings for two species of North American Moronidae, the striped bass (Morone saxatilis) and white perch (Morone americana), which spawn pelagic and demersal eggs, respectively in fresh water. Together with the high Vtg sequence homologies and virtually identical structural features of each type of Vtg between species, these findings indicate that the moronid multiple Vtg systems do not substantially vary with reproductive environment. Copyright © 2015 Elsevier Inc. All rights reserved.

  7. Defining Surrogate Endpoints for Clinical Trials in Severe Falciparum Malaria

    PubMed Central

    Plewes, Katherine; Maude, Richard J.; Hanson, Josh; Herdman, M. Trent; Leopold, Stije J.; Ngernseng, Thatsanun; Charunwatthana, Prakaykaew; Phu, Nguyen Hoan; Ghose, Aniruddha; Hasan, M. Mahtab Uddin; Fanello, Caterina I.; Faiz, Md Abul; Hien, Tran Tinh; Day, Nicholas P. J.; White, Nicholas J.; Dondorp, Arjen M.

    2017-01-01

    Background Clinical trials in severe falciparum malaria require a large sample size to detect clinically meaningful differences in mortality. This means few interventions can be evaluated at any time. Using a validated surrogate endpoint for mortality would provide a useful alternative allowing a smaller sample size. Here we evaluate changes in coma score and plasma lactate as surrogate endpoints for mortality in severe falciparum malaria. Methods Three datasets of clinical studies in severe malaria were re-evaluated: studies from Chittagong, Bangladesh (adults), the African ‘AQUAMAT’ trial comparing artesunate and quinine (children), and the Vietnamese ‘AQ’ study (adults) comparing artemether with quinine. The absolute change, relative change, slope of the normalization over time, and time to normalization were derived from sequential measurements of plasma lactate and coma score, and validated for their use as surrogate endpoint, including the proportion of treatment effect on mortality explained (PTE) by these surrogate measures. Results Improvements in lactate concentration or coma scores over the first 24 hours of admission, were strongly prognostic for survival in all datasets. In hyperlactataemic patients in the AQ study (n = 173), lower mortality with artemether compared to quinine closely correlated with faster reduction in plasma lactate concentration, with a high PTE of the relative change in plasma lactate at 8 and 12 hours of 0.81 and 0.75, respectively. In paediatric patients enrolled in the ‘AQUAMAT’ study with cerebral malaria (n = 785), mortality was lower with artesunate compared to quinine, but this was not associated with faster coma recovery. Conclusions The relative changes in plasma lactate concentration assessed at 8 or 12 hours after admission are valid surrogate endpoints for severe malaria studies on antimalarial drugs or adjuvant treatments aiming at improving the microcirculation. Measures of coma recovery are not valid surrogate endpoints for mortality. PMID:28052109

  8. Defining Surrogate Endpoints for Clinical Trials in Severe Falciparum Malaria.

    PubMed

    Jeeyapant, Atthanee; Kingston, Hugh W; Plewes, Katherine; Maude, Richard J; Hanson, Josh; Herdman, M Trent; Leopold, Stije J; Ngernseng, Thatsanun; Charunwatthana, Prakaykaew; Phu, Nguyen Hoan; Ghose, Aniruddha; Hasan, M Mahtab Uddin; Fanello, Caterina I; Faiz, Md Abul; Hien, Tran Tinh; Day, Nicholas P J; White, Nicholas J; Dondorp, Arjen M

    2017-01-01

    Clinical trials in severe falciparum malaria require a large sample size to detect clinically meaningful differences in mortality. This means few interventions can be evaluated at any time. Using a validated surrogate endpoint for mortality would provide a useful alternative allowing a smaller sample size. Here we evaluate changes in coma score and plasma lactate as surrogate endpoints for mortality in severe falciparum malaria. Three datasets of clinical studies in severe malaria were re-evaluated: studies from Chittagong, Bangladesh (adults), the African 'AQUAMAT' trial comparing artesunate and quinine (children), and the Vietnamese 'AQ' study (adults) comparing artemether with quinine. The absolute change, relative change, slope of the normalization over time, and time to normalization were derived from sequential measurements of plasma lactate and coma score, and validated for their use as surrogate endpoint, including the proportion of treatment effect on mortality explained (PTE) by these surrogate measures. Improvements in lactate concentration or coma scores over the first 24 hours of admission, were strongly prognostic for survival in all datasets. In hyperlactataemic patients in the AQ study (n = 173), lower mortality with artemether compared to quinine closely correlated with faster reduction in plasma lactate concentration, with a high PTE of the relative change in plasma lactate at 8 and 12 hours of 0.81 and 0.75, respectively. In paediatric patients enrolled in the 'AQUAMAT' study with cerebral malaria (n = 785), mortality was lower with artesunate compared to quinine, but this was not associated with faster coma recovery. The relative changes in plasma lactate concentration assessed at 8 or 12 hours after admission are valid surrogate endpoints for severe malaria studies on antimalarial drugs or adjuvant treatments aiming at improving the microcirculation. Measures of coma recovery are not valid surrogate endpoints for mortality.

  9. The Plasma Environment at Mercury

    NASA Technical Reports Server (NTRS)

    Raines, James M.; Gershman, Daniel J.; Zurbuchen, Thomas H.; Gloeckler, George; Slavin, James A.; Anderson, Brian J.; Korth, Haje; Krimigis, Stamatios M.; Killen, Rosemary M.; Sarantos, Menalos; hide

    2011-01-01

    Mercury is the least explored terrestrial planet, and the one subjected to the highest flux of solar radiation in the heliosphere. Its highly dynamic, miniature magnetosphere contains ions from the exosphere and solar wind, and at times may allow solar wind ions to directly impact the planet's surface. Together these features create a plasma environment that shares many features with, but is nonetheless very different from, that of Earth. The first in situ measurements of plasma ions in the Mercury space environment were made only recently, by the Fast Imaging Plasma Spectrometer (FIPS) during the MESSENGER spacecraft's three flybys of the planet in 2008-2009 as the probe was en route to insertion into orbit about Mercury earlier this year. Here. we present analysis of flyby and early orbital mission data with novel techniques that address the particular challenges inherent in these measurements. First. spacecraft structures and sensor orientation limit the FIPS field of view and allow only partial sampling of velocity distribution functions. We use a software model of FIPS sampling in velocity space to explore these effects and recover bulk parameters under certain assumptions. Second, the low densities found in the Mercury magnetosphere result in a relatively low signal-to-noise ratio for many ions. To address this issue, we apply a kernel density spread function to guide removal of background counts according to a background-signature probability map. We then assign individual counts to particular ion species with a time-of-flight forward model, taking into account energy losses in the carbon foil and other physical behavior of ions within the instrument. Using these methods, we have derived bulk plasma properties and heavy ion composition and evaluated them in the context of the Mercury magnetosphere.

  10. Study of dust in the vicinity of Dione using the Voyager 1 plasma wave instrument

    NASA Technical Reports Server (NTRS)

    Tsintikidis, D.; Kurth, W. S.; Gurnett, D. A.; Barbosa, D. D.

    1995-01-01

    The flyby of Voyager 1 at Saturn yielded the detection of a large variety of plasma waves, for example, chorus, hiss, and electron cyclotron harmonics. Just before the outbound equator crossing, the Voyager 1 plasma wave instrument detected a strong, well-defined low-frequency enhancement in signal levels. Initially, it was thought that this enhancement was due to plasma waves, but more recently it was suggested that dust impacts might be at least partial contributors. In this report we present evidence that dust impacts are partly responsible for the low-frequency enhancement. A new method of analysis which relies mainly on the 16-channel spectrum analyzer has been used to derive the dust impact rate. The available wideband waveform observations (which have been used previously to study dust impacts) were useful for calibrating the impact rate from the spectrum analyzer data. The mass and hence size of the dust particles were also obtained by analyzing the response of the plasma wave spectrum and analyzer. The results show that the region sampled by Voyager 1 is populated by dust particles that have rms masses of up to a few times 10(exp -11) g and sizes of up to a few microns. The dust particle number density is of the order of 10(exp -3)/cu m. The optical depth of the region sampled by the spacecraft is approximately 10(exp -6). The particle population is centered at 2470 (+/- 150) km south of the equatorial plane and has a north-south FWHM (full-width, half-maximum) thickness of 4130 (+/- 450) km. The dust may be part of the E ring or a localized ringlet assoicated with Dione.

  11. Clinical application of noradrenaline spillover methodology: delineation of regional human sympathetic nervous responses.

    PubMed

    Esler, M

    1993-11-01

    The proportionality which in general exists between rates of sympathetic nerve firing and the overflow of noradrenaline into the venous drainage of an organ provides the experimental justification for the use of measurements of noradrenaline in plasma as a biochemical measure of sympathetic nervous function. Static measurements of noradrenaline plasma concentration have several limitations. One is the confounding influence of noradrenaline plasma clearance on plasma concentration. Other drawbacks include the distortion arising from antecubital venous sampling (this represents but one venous drainage, that of the forearm), and the inability to detect regional differentiation of sympathetic responses. Clinical regional noradrenaline spillover measurements, performed with infusions of radiolabelled noradrenaline and sampling from centrally placed catheters, and derived from regional isotope dilution, overcome these deficiencies. The strength of the methodology is that sympathetic nervous function may be studied in the internal organs not accessible to nerve recording with microneurography. Examples of the regionalization of human sympathetic responses disclosed include the preferential activation of the cardiac sympathetic outflow with mental stress, cigarette smoking, aerobic exercise, cardiac failure, coronary insufficiency, essential hypertension and in ventricular arrhythmias, and the preferential stimulation or inhibition of the renal sympathetic nerves with low salt diets and mental stress, and with exercise training, respectively. By application of the same principles, regional release of the sympathetic cotransmitters neuropeptide Y and adrenaline can be studied in humans. Cotransmitter release, however, is detected only with some difficulty. In restricted circumstances we find evidence of regional cotransmitter release to plasma, such as the release of neuropeptide Y from the heart at the very high rates of sympathetic nerve firing occurring with aerobic exercise, and cardiac adrenaline release also with exercise and after loading of the neuronal adrenaline pool by intravenous infusion of adrenaline.

  12. Determination of plasma concentrations of levofloxacin by high performance liquid chromatography for use at a multidrug-resistant tuberculosis hospital in Tanzania

    PubMed Central

    Mpagama, Stellah; Kisonga, Riziki; Lekule, Isaack; Liu, Jie; Heysell, Scott

    2017-01-01

    Therapeutic drug monitoring may improve multidrug-resistant tuberculosis (MDR-TB) treatment outcomes. Levofloxacin demonstrates significant individual pharmacokinetic variability. Thus, we sought to develop and validate a high-performance liquid chromatography (HPLC) method with ultraviolet (UV) detection for levofloxacin in patients on MDR-TB treatment. The HPLC-UV method is based on a solid phase extraction (SPE) and a direct injection into the HPLC system. The limit of quantification was 0.25 μg/mL, and the assay was linear over the concentration range of 0.25—15 μg/mL (y = 0.5668x—0.0603, R2 = 0.9992) for the determination of levofloxacin in plasma. The HPLC-UV methodology achieved excellent accuracy and reproducibility along a clinically meaningful range. The intra-assay RSD% of low, medium, and high quality control samples (QC) were 1.93, 2.44, and 1.90, respectively, while the inter-assay RSD% were 3.74, 5.65, and 3.30, respectively. The mean recovery was 96.84%. This method was then utilized to measure levofloxacin concentrations from patients’ plasma samples from a retrospective cohort of consecutive enrolled subjects treated for MDR-TB at the national TB hospital in Tanzania during 5/3/2013–8/31/2015. Plasma was collected at 2 hours after levofloxacin administration, the time of estimated peak concentration (eCmax) treatment. Forty-one MDR-TB patients had plasma available and 39 had traceable programmatic outcomes. Only 13 (32%) patients had any plasma concentration that reached the lower range of the expected literature derived Cmax with the median eCmax being 5.86 (3.33–9.08 μg/ml). Using Classification and Regression Tree analysis, an eCmax ≥7.55 μg/mL was identified as the threshold which best predicted cure. Analyzing this CART derived threshold on treatment outcome, the time to sputum culture conversion was 38.3 ± 22.7 days vs. 47.8 ± 26.5 days (p = 0.27) and a greater proportion were cured, in 10 out of 15 (66.7%) vs. 6 out of 18 (33.3%) (p = 0.06) respectively. Furthermore, one patient with an eCmax/minimum inhibitory concentration (MIC) of only 1.13 acquired extensively drug resistant (XDR)-TB while undergoing treatment. The individual variability of levofloxacin concentrations in MDR-TB patients from Tanzania supports further study of the application of onsite therapeutic drug monitoring and MIC testing. PMID:28141813

  13. Determination of plasma concentrations of levofloxacin by high performance liquid chromatography for use at a multidrug-resistant tuberculosis hospital in Tanzania.

    PubMed

    Ebers, Andrew; Stroup, Suzanne; Mpagama, Stellah; Kisonga, Riziki; Lekule, Isaack; Liu, Jie; Heysell, Scott

    2017-01-01

    Therapeutic drug monitoring may improve multidrug-resistant tuberculosis (MDR-TB) treatment outcomes. Levofloxacin demonstrates significant individual pharmacokinetic variability. Thus, we sought to develop and validate a high-performance liquid chromatography (HPLC) method with ultraviolet (UV) detection for levofloxacin in patients on MDR-TB treatment. The HPLC-UV method is based on a solid phase extraction (SPE) and a direct injection into the HPLC system. The limit of quantification was 0.25 μg/mL, and the assay was linear over the concentration range of 0.25-15 μg/mL (y = 0.5668x-0.0603, R2 = 0.9992) for the determination of levofloxacin in plasma. The HPLC-UV methodology achieved excellent accuracy and reproducibility along a clinically meaningful range. The intra-assay RSD% of low, medium, and high quality control samples (QC) were 1.93, 2.44, and 1.90, respectively, while the inter-assay RSD% were 3.74, 5.65, and 3.30, respectively. The mean recovery was 96.84%. This method was then utilized to measure levofloxacin concentrations from patients' plasma samples from a retrospective cohort of consecutive enrolled subjects treated for MDR-TB at the national TB hospital in Tanzania during 5/3/2013-8/31/2015. Plasma was collected at 2 hours after levofloxacin administration, the time of estimated peak concentration (eCmax) treatment. Forty-one MDR-TB patients had plasma available and 39 had traceable programmatic outcomes. Only 13 (32%) patients had any plasma concentration that reached the lower range of the expected literature derived Cmax with the median eCmax being 5.86 (3.33-9.08 μg/ml). Using Classification and Regression Tree analysis, an eCmax ≥7.55 μg/mL was identified as the threshold which best predicted cure. Analyzing this CART derived threshold on treatment outcome, the time to sputum culture conversion was 38.3 ± 22.7 days vs. 47.8 ± 26.5 days (p = 0.27) and a greater proportion were cured, in 10 out of 15 (66.7%) vs. 6 out of 18 (33.3%) (p = 0.06) respectively. Furthermore, one patient with an eCmax/minimum inhibitory concentration (MIC) of only 1.13 acquired extensively drug resistant (XDR)-TB while undergoing treatment. The individual variability of levofloxacin concentrations in MDR-TB patients from Tanzania supports further study of the application of onsite therapeutic drug monitoring and MIC testing.

  14. Cracks and nanodroplets produced on tungsten surface samples by dense plasma jets

    NASA Astrophysics Data System (ADS)

    Ticoş, C. M.; Galaţanu, M.; Galaţanu, A.; Luculescu, C.; Scurtu, A.; Udrea, N.; Ticoş, D.; Dumitru, M.

    2018-03-01

    Small samples of 12.5 mm in diameter made from pure tungsten were exposed to a dense plasma jet produced by a coaxial plasma gun operated at 2 kJ. The surface of the samples was analyzed using a scanning electron microscope (SEM) before and after applying consecutive plasma shots. Cracks and craters were produced in the surface due to surface tensions during plasma heating. Nanodroplets and micron size droplets could be observed on the samples surface. An energy-dispersive spectroscopy (EDS) analysis revealed that the composition of these droplets coincided with that of the gun electrode material. Four types of samples were prepared by spark plasma sintering from powders with the average particle size ranging from 70 nanometers up to 80 μm. The plasma power load to the sample surface was estimated to be ≈4.7 MJ m-2 s-1/2 per shot. The electron temperature and density in the plasma jet had peak values 17 eV and 1.6 × 1022 m-3, respectively.

  15. Performance of plasma trigonelline as a marker of coffee consumption in an epidemiologic setting.

    PubMed

    Midttun, Øivind; Ulvik, Arve; Nygård, Ottar; Ueland, Per M

    2018-05-15

    Coffee is a widely consumed beverage, and studies suggest that drinking coffee has beneficial health effects. The phytohormone trigonelline is present in large amounts in coffee beans, and circulating concentrations of trigonelline have been shown to be positively related to dietary intake of coffee and to increase significantly after the consumption of a bolus dose of coffee. We cross-sectionally investigated the utility of plasma trigonelline as a marker of coffee consumption in an epidemiologic setting. We secondarily investigated if coffee intake is related to plasma concentrations of vitamin B-3 (niacin) forms. In a Norwegian cohort of 3503 participants, we combined questionnaire data on the number of cups of coffee consumed per day with plasma trigonelline to evaluate trigonelline as a marker of coffee intake. The suitability of plasma trigonelline to discriminate those not consuming from those consuming coffee was investigated by receiver operating characteristic (ROC) analysis. Plasma collected at 2 time points 1 y apart was used to determine the within-person reproducibility of trigonelline. We found that plasma trigonelline concentrations increased strongly with increasing amounts of coffee consumed. ROC analysis showed that trigonelline had an area under the curve of 0.92 (95% CI: 0.90, 0.94) for distinguishing coffee abstainers from coffee drinkers. Plasma trigonelline had a good within-person reproducibility (0.66; 95% CI: 0.64, 0.68) for samples collected 1 y apart. The amount of coffee consumed was not associated with plasma concentrations of the niacin vitamers nicotinamide and N1-methylnicotinamide. Plasma trigonelline performs well as a marker of coffee intake. Data used in this study were derived from the clinical trial registered at www.clinicaltrials.gov as NCT00354081.

  16. Sterilization of Turmeric by Atmospheric Pressure Dielectric Barrier Discharge Plasma

    NASA Astrophysics Data System (ADS)

    Setareh, Salarieh; Davoud, Dorranian

    2013-11-01

    In this study atmospheric pressure dielectric barrier discharge (DBD) plasma has been employed for sterilizing dry turmeric powders. A 6 kV, 6 kHz frequency generator was used to generate plasma with Ar, Ar/O2, He, and He/O2 gases between the 5 mm gap of two quartz covered electrodes. The complete sterilization time of samples due to plasma treatment was measured. The most important contaminant of turmeric is bacillus subtilis. The results show that the shortest sterilization time of 15 min is achieved by exposing the samples to Ar/O2 plasma. Survival curves of samples are exponential functions of time and the addition of oxygen to plasma leads to a significant increase of the absolute value of time constant of the curves. Magnitudes of protein and DNA in treated samples were increased to a similar value for all samples. Taste, color, and solubility of samples were not changed after the plasma treatment.

  17. Sexually-Transmitted/Founder HIV-1 Cannot Be Directly Predicted from Plasma or PBMC-Derived Viral Quasispecies in the Transmitting Partner

    PubMed Central

    Frange, Pierre; Meyer, Laurence; Jung, Matthieu; Goujard, Cecile; Zucman, David; Abel, Sylvie; Hochedez, Patrick; Gousset, Marine; Gascuel, Olivier; Rouzioux, Christine; Chaix, Marie-Laure

    2013-01-01

    Objective Characterization of HIV-1 sequences in newly infected individuals is important for elucidating the mechanisms of viral sexual transmission. We report the identification of transmitted/founder viruses in eight pairs of HIV-1 sexually-infected patients enrolled at the time of primary infection (“recipients”) and their transmitting partners (“donors”). Methods Using a single genome-amplification approach, we compared quasispecies in donors and recipients on the basis of 316 and 376 C2V5 env sequences amplified from plasma viral RNA and PBMC-associated DNA, respectively. Results Both DNA and RNA sequences indicated very homogeneous viral populations in all recipients, suggesting transmission of a single variant, even in cases of recent sexually transmitted infections (STIs) in donors (n = 2) or recipients (n = 3). In all pairs, the transmitted/founder virus was derived from an infrequent variant population within the blood of the donor. The donor variant sequences most closely related to the recipient sequences were found in plasma samples in 3/8 cases and/or in PBMC samples in 6/8 cases. Although donors were exclusively (n = 4) or predominantly (n = 4) infected by CCR5-tropic (R5) strains, two recipients were infected with highly homogeneous CXCR4/dual-mixed-tropic (X4/DM) viral populations, identified in both DNA and RNA. The proportion of X4/DM quasispecies in donors was higher in cases of X4/DM than R5 HIV transmission (16.7–22.0% versus 0–2.6%), suggesting that X4/DM transmission may be associated with a threshold population of X4/DM circulating quasispecies in donors. Conclusions These suggest that a severe genetic bottleneck occurs during subtype B HIV-1 heterosexual and homosexual transmission. Sexually-transmitted/founder virus cannot be directly predicted by analysis of the donor’s quasispecies in plasma and/or PBMC. Additional studies are required to fully understand the traits that confer the capacity to transmit and establish infection, and determine the role of concomitant STIs in mitigating the genetic bottleneck in mucosal HIV transmission. PMID:23874894

  18. Simultaneous quantification of preactivated ifosfamide derivatives and of 4-hydroxyifosfamide by high performance liquid chromatography-tandem mass spectrometry in mouse plasma and its application to a pharmacokinetic study.

    PubMed

    Deroussent, Alain; Skarbek, Charles; Maury, Adeline; Chapuis, Hubert; Daudigeos-Dubus, Estelle; Le Dret, Ludivine; Durand, Sylvère; Couvreur, Patrick; Desmaële, Didier; Paci, Angelo

    2015-06-15

    The antitumor drug, ifosfamide (IFO), requires activation by cytochrome P450 (CYP) to form the active metabolite, 4-hydroxyisfosfamide (4-OHIFO), leading to toxic by-products at high dose. In order to overcome these drawbacks, preactivated ifosfamide derivatives (RXIFO) were designed to release 4-OHIFO without CYP involvement. A high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) method was developed for the simultaneous quantification of 4-OHIFO, IFO and four derivatives RXIFO in mouse plasma using multiple reaction monitoring. Because of its instability in plasma, 4-OHIFO was immediately converted to the semi-carbazone derivative, 4-OHIFO-SCZ. For the six analytes, the calibration curves were linear from 20 to 5000ng/mL in 50μL plasma and the lower limit of quantitation was determined at 20ng/mL with accuracies within ±10% of nominal and precisions less than 12%. Their recoveries ranged from 62 to 96% by using liquid-liquid extraction. With an improved assay sensitivity compared to analogues, the derivative 4-OHIFO-SCZ was stable in plasma at 4°C for 24h and at -20°C for three months. For all compounds, the assay was validated with accuracies within ±13% and precisions less than 15%. This method was applied to a comparative pharmacokinetic study of 4-OHIFO from IFO and three derivatives RXIFO in mice. This active metabolite was produced by some of the novel conjugates with good pharmacokinetic properties. Copyright © 2015 Elsevier B.V. All rights reserved.

  19. Plasma oscillations in spherical Gaussian shaped ultracold neutral plasma

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chen, Tianxing; Lu, Ronghua, E-mail: lurh@siom.ac.cn; Guo, Li

    2016-04-15

    The collective plasma oscillations are investigated in ultracold neutral plasma with a non-uniform density profile. Instead of the plane configuration widely used, we derive the plasma oscillation equations with spherically symmetric distribution and Gaussian density profile. The damping of radial oscillation is found. The Tonks–Dattner resonances of the ultracold neutral plasma with an applied RF field are also calculated.

  20. Kinetics, Longevity, and Cross-Reactivity of Antineuraminidase Antibody after Natural Infection with Influenza A Viruses.

    PubMed

    Changsom, Don; Jiang, Li; Lerdsamran, Hatairat; Iamsirithaworn, Sopon; Kitphati, Rungrueng; Pooruk, Phisanu; Auewarakul, Prasert; Puthavathana, Pilaipan

    2017-12-01

    The kinetics, longevity, and breadth of antibodies to influenza virus neuraminidase (NA) in archival, sequential serum/plasma samples from influenza A virus (IAV) H5N1 infection survivors and from patients infected with the 2009 pandemic IAV (H1N1) virus were determined using an enzyme-linked lectin-based assay. The reverse-genetics-derived H4N1 viruses harboring a hemagglutinin (HA) segment from A/duck/Shan Tou/461/2000 (H4N9) and an NA segment derived from either IAV H5N1 clade 1, IAV H5N1 clade 2.3.4, the 2009 pandemic IAV (H1N1) (H1N1pdm), or A/Puerto Rico/8/1934 (H1N1) virus were used as the test antigens. These serum/plasma samples were also investigated by microneutralization (MN) and/or hemagglutination inhibition (HI) assays. Neuraminidase-inhibiting (NI) antibodies against N1 NA of both homologous and heterologous viruses were observed in H5N1 survivors and H1N1pdm patients. H5N1 survivors who were never exposed to H1N1pdm virus developed NI antibodies to H1N1pdm NA. Seroconversion of NI antibodies was observed in 65% of the H1N1pdm patients at day 7 after disease onset, but an increase in titer was not observed in serum samples obtained late in infection. On the other hand, an increase in seroconversion rate with the HI assay was observed in the follow-up series of sera obtained on days 7, 14, 28, and 90 after infection. The study also showed that NI antibodies are broadly reactive, while MN and HI antibodies are more strain specific. Copyright © 2017 American Society for Microbiology.

  1. What can be learned in the snake antivenom field from the developments in human plasma derived products?

    PubMed

    Burnouf, Thierry

    2018-05-01

    Human plasma-derived medicinal products and snake antivenom immunoglobulins are unique and complex therapeutic protein products. Human plasma products are obtained by fractionating large pools of plasma collected from blood plasma donors. They comprise a wide range of protein products, including polyvalent and hyperimmune immunoglobulins, coagulation factors, albumin, and various protease inhibitors that are transfused to patients affected by congenital or acquired protein deficiencies, immunological disorders, or metabolic diseases. Snake antivenoms are manufactured from pools of plasma collected from animals, typically horses, which have been immunized against snake venoms. Transfusing antivenoms is the cornerstone therapy to treat patients affected by snakebite envenoming. Over the last thirty years, much technical and regulatory evolution has been implemented to ensure that this class of biologicals meets modern quality requirements. The purpose of this review is to compare the main developments that took place in plasma production, protein fractionation, pathogen safety, quality control, preclinical and clinical studies, and regulations of these products. We also analyze whether both fields have been influencing and cross-fertilizing each other technically and in regulatory aspects to reach modern safety and efficacy standards at global levels, and how experience in the human plasma fractionation industry can further impact the manufacture of snake antivenom and that of other animal-derived antisera. Copyright © 2018 Elsevier Ltd. All rights reserved.

  2. Modeling of negative ion extraction from a magnetized plasma source: Derivation of scaling laws and description of the origins of aberrations in the ion beam

    NASA Astrophysics Data System (ADS)

    Fubiani, G.; Garrigues, L.; Boeuf, J. P.

    2018-02-01

    We model the extraction of negative ions from a high brightness high power magnetized negative ion source. The model is a Particle-In-Cell (PIC) algorithm with Monte-Carlo Collisions. The negative ions are generated only on the plasma grid surface (which separates the plasma from the electrostatic accelerator downstream). The scope of this work is to derive scaling laws for the negative ion beam properties versus the extraction voltage (potential of the first grid of the accelerator) and plasma density and investigate the origins of aberrations on the ion beam. We show that a given value of the negative ion beam perveance correlates rather well with the beam profile on the extraction grid independent of the simulated plasma density. Furthermore, the extracted beam current may be scaled to any value of the plasma density. The scaling factor must be derived numerically but the overall gain of computational cost compared to performing a PIC simulation at the real plasma density is significant. Aberrations appear for a meniscus curvature radius of the order of the radius of the grid aperture. These aberrations cannot be cancelled out by switching to a chamfered grid aperture (as in the case of positive ions).

  3. Kinetic equations for cylindrically symmetric plasmas including atomic coherence and Coulomb potential effects

    NASA Astrophysics Data System (ADS)

    Csanak, G.; Fontes, C. J.; Kilcrease, D. P.; Hakel, P.; Inal, M. K.

    2017-05-01

    The rate equations used to model plasma kinetics and spectroscopy are typically obtained from intuitive considerations. A few years ago, the authors (Csanak et al 2011 J. Phys. B: At. Mol. Opt. Phys. 44 215701) have shown that the population-alignment collisional-radiative (CR) model and the magnetic sublevel to magnetic sublevel rate-equation scheme can be obtained from the Fano-Ben-Reuven quantum impact approximation (QIA). Here we provide a formal derivation of the rate-equation schemes for modeling hydrogenic plasmas and highly charged ionic plasmas with cylindrical symmetry using the QIA under certain approximations. In the case of hydrogenic plasmas the ‘accidental degeneracy’ (if present) leads to some coherences among the excited states of the atom (or ion) that have to be taken into account when constructing the rate equations. In the case of highly charged plasmas the Coulomb potential can be taken into account (as suggested originally by Baranger) in defining the ‘bath particles’, which leads to a derivation of the kinetic equations where no singularity occurs. For the case of spherically symmetric plasmas, this method also provides a derivation of the standard CR equations that have been implemented in many codes to successfully model the kinetics and spectra of highly charged ions.

  4. Individualized correction of insulin measurement in hemolyzed serum samples.

    PubMed

    Wu, Zhi-Qi; Lu, Ju; Chen, Huanhuan; Chen, Wensen; Xu, Hua-Guo

    2017-06-01

    Insulin measurement plays a key role in the investigation of patients with hypoglycemia, subtype classification of diabetes mellitus, insulin resistance, and impaired beta cell function. However, even slight hemolysis can negatively affect insulin measurement due to RBC insulin-degrading enzyme (IDE). Here, we derived and validated an individualized correction equation in an attempt to eliminate the effects of hemolysis on insulin measurement. The effects of hemolysis on insulin measurement were studied by adding lysed self-RBCs to serum. A correction equation was derived, accounting for both percentage and exposure time of hemolysis. The performance of this individualized correction was evaluated in intentionally hemolyzed samples. Insulin concentration decreased with increasing percentage and exposure time of hemolysis. Based on the effects of hemolysis on insulin measurement of 17 donors (baseline insulin concentrations ranged from 156 to 2119 pmol/L), the individualized hemolysis correction equation was derived: INS corr  = INS meas /(0.705lgHb plasma /Hb serum  - 0.001Time - 0.612). This equation can revert insulin concentrations of the intentionally hemolyzed samples to values that were statistically not different from the corresponding insulin baseline concentrations (p = 0.1564). Hemolysis could lead to a negative interference on insulin measurement; by individualized hemolysis correction equation for insulin measurement, we can correct and report reliable serum insulin results for a wide range of degrees of sample hemolysis. This correction would increase diagnostic accuracy, reduce inappropriate therapeutic decisions, and improve patient satisfaction with care.

  5. Relativistically correct DD and DT neutron spectra

    NASA Astrophysics Data System (ADS)

    Appelbe, B.; Chittenden, J.

    2014-06-01

    We use relativistic kinematics to derive an expression for the energy spectrum of neutrons produced by fusion reactions in deuterium and deuterium-tritium thermal plasmas. The derivation does not require approximations and the obtained expression gives the exact shape of the spectrum. It is shown that the high-energy tail of the neutron spectrum is highly sensitive to the plasma temperature. Simple expressions for the plasma temperature as a function of the neutron spectrum full width at half maximum (FWHM) are given.

  6. Effects of Six-Week Ginkgo biloba Supplementation on Aerobic Performance, Blood Pro/Antioxidant Balance, and Serum Brain-Derived Neurotrophic Factor in Physically Active Men.

    PubMed

    Sadowska-Krępa, Ewa; Kłapcińska, Barbara; Pokora, Ilona; Domaszewski, Przemysław; Kempa, Katarzyna; Podgórski, Tomasz

    2017-07-26

    Extracts of Ginkgo biloba leaves, a natural source of flavonoids and polyphenolic compounds, are commonly used as therapeutic agents for the improvement of both cognitive and physiological performance. The present study was aimed to test the effects of a six-week supplementation with 160 mg/day of a standardized extract of Ginkgo biloba or a matching placebo on aerobic performance, blood antioxidant capacity, and brain-derived neurotrophic factor (BDNF) level in healthy, physically active young men, randomly allocated to two groups ( n = 9 each). At baseline, as well as on the day following the treatment, the participants performed an incremental cycling test for the assessment of maximal oxygen uptake. Venous blood samples taken at rest, then immediately post-test and following 1 h of recovery, were analyzed for activities of antioxidant enzymes and plasma concentrations of non-enzymatic antioxidants, total phenolics, uric acid, lipid peroxidation products, ferric reducing ability of plasma (FRAP), and serum brain-derived neurotrophic factor (BDNF). Our results show that six weeks' supplementation with Ginkgo biloba extract in physically active young men may provide some marginal improvements in their endurance performance expressed as VO₂max and blood antioxidant capacity, as evidenced by specific biomarkers, and elicit somewhat better neuroprotection through increased exercise-induced production of BDNF.

  7. Inner Magnetospheric Electric Fields Derived from IMAGE EUV

    NASA Technical Reports Server (NTRS)

    Gallagher, D. L.; Adrian, M. L.

    2007-01-01

    The local and global patterns of plasmaspheric plasma transport reflect the influence of electric fields imposed by all sources in the inner magnetosphere. Image sequences of thermal plasma G:istribution obtained from the IMAGE Mission Extreme Ultraviolet Imager can be used to derive plasma motions and, using a magnetic field model, the corresponding electric fields. These motions and fields directly reflect the dynamic coupling of injected plasmasheet plasma and the ionosphere, in addition to solar wind and atmospheric drivers. What is being learned about the morphology of inner magnetospheric electric fields during storm and quite conditions from this new empirical tool will be presented and discussed.

  8. Effect of polarization force on the Jeans instability in collisional dusty plasmas

    NASA Astrophysics Data System (ADS)

    A, ABBASI; M, R. RASHIDIAN VAZIRI

    2018-03-01

    The Jeans instability in collisional dusty plasmas has been analytically investigated by considering the polarization force effect. Instabilities due to dust-neutral and ion-neutral drags can occur in electrostatic waves of collisional dusty plasmas with self-gravitating particles. In this study, the effect of gravitational force on heavy dust particles is considered in tandem with both the polarization and electrostatic forces. The theoretical framework has been developed and the dispersion relation and instability growth rate have been derived, assuming the plane wave approximation. The derived instability growth rate shows that, in collisional dusty plasmas, the Jeans instability strongly depends on the magnitude of the polarization force.

  9. A new method for measuring oxidative stress in claudicants during strenuous exercise using free radical derivatives of antipyrine as indicators: a pilot study.

    PubMed

    Coolen, Stefan A J; Wijnen, Marc H W A; Reijenga, Jetse C; Vader, Huib L; Roumen, Rudi M H; Huf, Fred A

    2002-01-01

    Patients with intermittent claudication disease suffer from temporary lack of oxygen in the legs, caused by narrowing of arteries, resulting in ischemia and followed by reperfusion. The degree of oxidative stress present in 16 patients during strenuous exercise was determined using several indicators. Two derivatives of an exogenous marker, antipyrine (AP), (ie, p-hydroxyantipyrine, p-APOH, and o-hydroxyantipyrine, o-APOH), were assayed in plasma using HPLC-tandem-MS. Plasma malondialdehyde (assayed as thiobarbituric acid reactive species, TBARS) was also determined. The branchial/ankle blood pressure index (b-a index) was used to assess the severity of intermittent claudication disease, and plasma lactate concentration was also measured as an indicator of the ischemic situation. Plasma TBARS level did not change significantly after exercise. During the ischemic situation as well as during reperfusion, both free radical derivatives of antipyrine increased significantly in plasma (p < 0.01). Because p-APOH is also formed enzymatically in humans, the plasma ratio of o-APOH to AP appeared to be the most specific marker for oxidative stress in patients with intermittent claudication.

  10. Plasma surface cleaning in a microwave plasma source

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tsai, C.C.; Nelson, W.D.; Haselton, H.H.

    1994-03-01

    A microwave electron cyclotron resonance (ECR) plasma source has been operated to produce reactive plasmas of oxygen and its mixture with argon. Aluminum samples (0.95 cm by 1.9 cm) were coated with thin films (<20 {mu}m in thickness) of Shell Vitrea oil and cleaned by using such reactive plasmas. The plasma cleaning was done in discharge conditions of microwave power up to 1300 W, radio frequency power up to 200 W, biased potential up to 400 V, gas pressures up to 5 mtorr, and operating time up to 35 min. The surface texture of the postcleaned samples has been examinedmore » visually. Mass loss of the samples after plasma cleaning was measured to estimate cleaning rates. Measured clean rates of low-pressure (0.5-mtorr) argon/oxygen plasmas were as high as 2.7 {mu}m/min. X-ray photoelectron spectroscopy (XPS) was used to determine cleanliness of the sample surfaces after plasma cleaning. The XPS study on polished samples confirmed the effectiveness of plasma cleaning in achieving atomic level of surface cleanliness. In this technical memorandum plasma properties, cleaning phenomena, and significant results are reported and discussed.« less

  11. Experimentally Determined Plasma Parameters in a 30 cm Ion Engine

    NASA Technical Reports Server (NTRS)

    Sengupta, Anita; Goebel, Dan; Fitzgerald, Dennis; Owens, Al; Tynan, George; Dorner, Russ

    2004-01-01

    Single planar Langmuir probes and fiber optic probes are used to concurrently measure the plasma properties and neutral density variation in a 30cm diameter ion engine discharge chamber, from the immediate vicinity of the keeper to the near grid plasma region. The fiber optic probe consists of a collimated optical fiber recessed into a double bore ceramic tube fitted with a stainless steel light-limiting window. The optical fiber probe is used to measure the emission intensity of excited neutral xenon for a small volume of plasma, at various radial and axial locations. The single Langmuir probes, are used to generate current-voltage characteristics at a total of 140 spatial locations inside the discharge chamber. Assuming a maxwellian distribution for the electron population, the Langmuir probe traces provide spatially resolved measurements of plasma potential, electron temperature, and plasma density. Data reduction for the NSTAR TH8 and TH15 throttle points indicates an electron temperature range of 1 to 7.9 eV and an electron density range of 4e10 to le13 cm(sup -3), throughout the discharge chamber, consistent with the results in the literature. Plasma potential estimates, computed from the first derivative of the probe characteristic, indicate potential from 0.5V to 11V above the discharge voltage along the thruster centerline. These values are believed to be excessively high due to the sampling of the primary electron population along the thruster centerline. Relative neutral density profiles are also obtained with a fiber optic probe sampling photon flux from the 823.1 nm excited to ground state transition. Plasma parameter measurements and neutral density profiles will be presented as a function of probe location and engine discharge conditions. A discussion of the measured electron energy distribution function will also be presented, with regards to variation from pure maxwellian. It has been found that there is a distinct primary population found along the thruster centerline, which causes estimates of electron temperature, electron density, and plasma potential, to err on the high side, due this energetic population. Computation of the energy distribution fimction of the plasma clearly indicates the presence of primaries, whose presence become less obvious with radial distance from the main discharge plume.

  12. Stability of Atmospheric-Pressure Plasma Induced Changes on Polycarbonate Surfaces

    NASA Technical Reports Server (NTRS)

    Sharma, Rajesh; Holcomb, Edward; Trigwell, Steve

    2006-01-01

    Polycarbonate films are subjected to plasma treatment in a number of applications such as improving adhesion between polycarbonate and silicon alloy in protective and optical coatings. The changes in surface chemistry due to plasma treatment have tendency to revert back. Thus stability of the plasma induced changes on polymer surfaces over desired time period is very important. The objective of this study was to examine the effect of ageing on atmospheric pressure helium-plasma treated polycarbonate (PC) sample as a function of treatment time. The ageing effects were studied over a period of 10 days. The samples were plasma treated for 0.5, 2, 5 and 10 minutes. Contact angle measurements were made to study surface energy changes. Modification of surface chemical structure was examined using, X-ray Photoelectron Spectroscopy (XPS). Contact angle measurements on untreated and plasma treated surfaces were made immediately, 24, 48, 72 and 96 hrs after treatment. Contact angle decreased from 93 deg for untreated sample to 30 deg for sample plasma treated for 10 minutes. After 10 days the contact angles for the 10 minute plasma treated sample increased to 67 deg, but it never reverted back to that of untreated surface. Similarly the O/C ratio increased from 0.136 for untreated sample to 0.321 for 10 minute plasma treated sample indication increase in surface energy.

  13. Proteomic Characterization of Dermal Interstitial Fluid Extracted Using a Novel Microneedle-Assisted Technique.

    PubMed

    Tran, Bao Quoc; Miller, Philip R; Taylor, Robert M; Boyd, Gabrielle; Mach, Phillip M; Rosenzweig, C Nicole; Baca, Justin T; Polsky, Ronen; Glaros, Trevor

    2018-01-05

    As wearable fitness devices have gained commercial acceptance, interest in real-time monitoring of an individual's physiological status using noninvasive techniques has grown. Microneedles have been proposed as a minimally invasive technique for sampling the dermal interstitial fluid (ISF) for clinical monitoring and diagnosis, but little is known about its composition. In this study, a novel microneedle array was used to collect dermal ISF from three healthy human donors and compared with matching serum and plasma samples. Using a shotgun quantitative proteomic approach, 407 proteins were quantified with at least one unique peptide, and of those, 135 proteins were differently expressed at least 2-fold. Collectively, these proteins tended to originate from the cytoplasm, membrane bound vesicles, and extracellular vesicular exosomes. Proteomic analysis confirmed previously published work that indicates that ISF is highly similar to both plasma and serum. In this study, less than one percent of proteins were uniquely identified in ISF. Taken together, ISF could serve as a minimally invasive alternative for blood-derived fluids with potential for real-time monitoring applications.

  14. Analysis of nutrition-relevant trace elements in human blood and serum by means of total reflection X-ray fluorescence (TXRF) spectroscopy

    NASA Astrophysics Data System (ADS)

    Stosnach, Hagen; Mages, Margarete

    2009-04-01

    In clinical service laboratories, one of the most common analytical tasks with regard to inorganic traces is the determination of the nutrition-relevant elements Fe, Cu, Zn, and Se. Because of the high numbers of samples and the commercial character of these analyses, a time-consuming sample preparation must be avoided. In this presentation, the results of total reflection X-ray fluorescence measurements with a low-power system and different sample preparation procedures are compared with those derived from analysis with common methods like Atomic Absorption Spectroscopy (AAS) and Inductively Coupled Plasma Mass Spectroscopy (ICP-MS). The results of these investigations indicate that the optimal total reflection X-ray fluorescence analysis of the nutrition-relevant elements Fe, Cu, Zn, and Se can be performed by preparing whole blood and serum samples after dilution with ultrapure water and transferring 10 μl of internally standardized sample to an unsiliconized quartz glass sample carrier with subsequent drying in a laboratory oven. Suitable measurement time was found to be 600 s. The enhanced sample preparation by means of microwave or open digestion, in parts combined with cold plasma ashing, led to an improvement of detection limits by a factor of 2 for serum samples while for whole blood samples an improvement was only observed for samples prepared by means of microwave digestion. As the matrix elements P, S, Cl, and for whole blood Fe have a major influence on the detection limits, most probably a further enhancement of analytical quality requires the removal of the organic matrix. However, for the routine analysis of the nutrition-relevant elements, the dilution preparation was found to be sufficient.

  15. In vitro control of human bone marrow stromal cells for bone tissue engineering.

    PubMed

    Anselme, Karine; Broux, Odile; Noel, Benoit; Bouxin, Bertrand; Bascoulergue, Gerard; Dudermel, Anne-France; Bianchi, Fabien; Jeanfils, Joseph; Hardouin, Pierre

    2002-12-01

    For the clinical application of cultured human mesenchymal stem cells (MSCs), cells must have minimal contact with fetal calf serum (FCS) because it might be a potential vector for contamination by adventitious agents. The use of human plasma and serum for clinical applications also continues to give rise to considerable concerns with respect to the transmission of known and unknown human infectious agents. With the objective of clinical applications of cultured human MSCs, we tested the ability of autologous plasma, AB human serum, FCS, and artificial serum substitutes containing animal-derived proteins (Ultroser G) or vegetable-derived proteins (Prolifix S6) to permit their growth and differentiation in vitro. To conserve as much autologous plasma as possible, we attempted to mix it at decreasing concentrations with the serum substitute containing vegetable-derived mitogenic factors. Under control conditions, by day 10 all the fibroblast colony-forming units (CFU-Fs) were alkaline phosphatase (ALP) positive. However, their number and size were highly variable among donors. Better CFU-F formation was obtained with Ultroser G, and with human AB serum and autologous plasma mixed at, respectively, 5 and 1% with Prolifix S6. The effects of these mixtures on CFU-F formation demonstrate synergy, with the human serum or plasma supplying the factors that favor differentiation of MSCs while Prolifix S6 supplies the mitogenic factors. Finally, we demonstrated the possibility of controlling human MSC growth and differentiation in vitro. Notably, by means of a minimal quantity of human serum or human plasma mixed with a new serum substitute containing vegetable-derived proteins, we displayed growth and differentiation of human MSCs comparable to that obtained with FCS or serum substitutes containing animal-derived proteins. These results will have crucial significance for future applications of cultured human MSCs in bone tissue engineering.

  16. Pharmacokinetics of taurolidine following repeated intravenous infusions measured by HPLC-ESI-MS/MS of the derivatives taurultame and taurinamide in glioblastoma patients.

    PubMed

    Stendel, Ruediger; Scheurer, Louis; Schlatterer, Kathrin; Stalder, Urs; Pfirrmann, Rolf W; Fiss, Ingo; Möhler, Hanns; Bigler, Laurent

    2007-01-01

    Taurolidine is known to have antimicrobial activity. Furthermore, at lower concentrations, it has been found to exert a selective antineoplastic effect in vitro and in vivo. The aim of this study was to investigate the pharmacokinetics of taurolidine in vivo following repeated intravenous infusion in a schedule used for the treatment of glioblastoma. As a prerequisite, the pharmacokinetics of taurolidine in human blood plasma and whole blood in vitro was investigated. The pharmacokinetics of taurolidine and its derivatives taurultame and taurinamide were investigated in human blood plasma and in whole blood in vitro using blood from a healthy male volunteer. During repeated intravenous infusion therapy with taurolidine, plasma samples were taken every hour for a period of 13 hours per day in seven patients (three male, four female; mean age 48.4 +/- 12.8 years, range 27-66 years) with a glioblastoma. Following dansyl derivatisation, the concentrations of taurultame and taurinamide were determined using a new method based on high-performance liquid chromatography (HPLC) online coupled to electrospray ionisation tandem mass spectrometry (ESI-MS/MS) in the multiple reaction monitoring mode. Under the experimental conditions used, taurolidine could not be determined directly and was back-calculated from the taurultame and taurinamide values. The new HPLC-ESI-MS/MS method demonstrated high accuracy and reproducibility. In vitro plasma concentrations of taurultame and taurinamide remained constant over the incubation period. In whole blood in vitro, a time-dependent formation of taurinamide was observed. At the start of the incubation, the taurultame-taurinamide ratio (TTR) was 0.95 at an initial taurolidine concentration of 50 microg/mL, and 1.69 at 100 microg/mL. The concentration of taurultame decreased at the same rate as the taurinamide concentration increased, showing logarithmic kinetics. The calculated taurolidine concentration remained largely constant over the 6-hour incubation period. During repeated infusions in patients, calculated plasma concentrations of taurolidine showed a strong increase after the start of each infusion and continued to increase until the end of infusion, followed by a rapid decline. The TTR was found to fluctuate between 0.1 and 0.3, depending on the relation to the previous or next infusion period. The volume of distribution was markedly higher for taurolidine, taurultame and taurinamide than the plasma volume. Taurolidine displayed a stable pattern of derivatives in plasma in vitro, whereas in whole blood, a time- and concentration-dependent conversion was apparent. In patients, the calculated average taurolidine plasma concentration, achieved with the repeated infusion regimen, was in the antineoplastic-effective concentration range. The tissue concentrations of taurolidine and taurultame are expected to be higher than the plasma concentrations, taking into account the calculated volumes of distribution. Repeated infusion of taurolidine is the therapeutically adequate mode of administration for the indication of glioblastoma.

  17. Components in Plasma-Derived Factor VIII, But Not in Recombinant Factor VIII Downregulate Anti-Inflammatory Surface Marker CD163 in Human Macrophages through Release of CXCL4 (Platelet Factor 4)

    PubMed Central

    Bertling, Anne; Brodde, Martin F.; Visser, Mayken; Treffon, Janina; Fennen, Michelle; Fender, Anke C.; Kelsch, Reinhard; Kehrel, Beate E.

    2017-01-01

    Background Hemarthrosis, or bleeding into the joints, is a hallmark of hemophilia. Heme triggers oxidative stress, inflammation, and destruction of cartilage and bone. The haptoglobin-CD163-heme oxygenase-1 (HO-1) pathway circumvents heme toxicity through enzymatic degradation of heme and transcription of antioxidant genes. Plasma-derived factor concentrates contain many proteins that might impact on cellular pathways in joints, blood, and vessels. Methods Activation of platelets from healthy volunteers was assessed by flow cytometry analysis of fibrinogen binding and CD62P expression. Platelet CXCL4 release was measured by ELISA. Human peripheral blood mononuclear cells were exposed to CXCL4 or platelet supernatants (untreated or pre-stimulated with factor VIII (FVIII) products) during their differentiation to macrophages and analyzed for CD163 expression. Some macrophage cultures were additionally incubated with autologous hemoglobin for 18 h for analysis of HO-1 expression. Results Platelet CXCL4 release was increased by all 8 tested plasma-derived FVIII products but not the 3 recombinant products. Macrophages exposed to supernatant from platelets treated with some plasma-derived FVIII products downregulated CD163 surface expression and failed to upregulate the athero- and joint protective enzyme HO-1 in response to hemoglobin. Conclusion Plasma-derived FVIII products might promote bleeding-induced joint injury via generation of macrophages that are unable to counteract redox stress. PMID:29070980

  18. Creation of fluorocarbon barriers on surfaces of starch-based products through cold plasma treatment

    NASA Astrophysics Data System (ADS)

    Han, Yousoo

    Two kinds of starch foam trays (starch and aspen-starch foam trays) were produced using a lab model baking machine. Surfaces of the trays were treated with CF4 and SF6 plasma to create fluorine-rich layers on the surfaces, which might show strong water resistance. The plasma parameters, such like RF power, gas pressure and reaction time, were varied to evaluate the effects of each parameter on fluorination of surfaces. The atomic concentrations of fluorine, oxygen and carbon on samples' surfaces were earned from ESCA (electron spectroscopy for chemical analysis) and contact angles of sample surfaces were measured for hydrophobicity. For water resistance of plasma treated surfaces, liquid water uptake and water vapor uptake test were performed. Also, equilibrium moisture contents of unmodified and plasma treated samples were measured to evaluate biodegradability of plasma treated samples. Fluorine-rich barriers were created on sample surfaces treated with CF 4 and SF6 plasma. The fluorine atomic concentrations of treated sample surfaces were ranged from 34.4% to 64.4% (CF4 treatment) and 43.6% to 57.9% (SF6 treatment). It was found at both plasma gases that plasma parameters affected total fluorine concentration and carbon-peak shapes in ESCA surveys, which imply different distributions of mono- or multi-fluoro carbon's contents. In various reaction times, it was found that total fluorine contents were decreased after a critical point as the reaction time was prolonged, which may imply that a dominant mechanism has been changed from deposition or functionalization to etching. Oxygen atomic concentration was decreased at sample surfaces treated by both plasmas. In the case of SF6 plasma, it was proved that the removal of oxygen surely occurred because there was no addition of sulfur species. Plasma treated sample surfaces had high contact angles with distilled water up to 150° and the high values of angles have been kept constant up to for 15 minutes. Fluorine-rich barriers created by plasma showed lower water liquid and vapor permeability than untreated surfaces did. Plasma treated samples had similar moisture contents with untreated samples at all relative humidity tested. AFM and SEM images were taken for sample surfaces' morphology and topography.

  19. Microparticles variability in fresh frozen plasma: preparation protocol and storage time effects

    PubMed Central

    Kriebardis, Anastasios G.; Antonelou, Marianna H.; Georgatzakou, Hara T.; Tzounakas, Vassilis L.; Stamoulis, Konstantinos E.; Papassideri, Issidora S.

    2016-01-01

    Background Extracellular vesicles or microparticles exhibiting procoagulant and thrombogenic activity may contribute to the haemostatic potential of fresh frozen plasma. Materials and methods Fresh frozen plasma was prepared from platelet-rich plasma at 20 °C (Group-1 donors) or directly from whole blood at 4 °C (Group-2 donors). Each unit was aseptically divided into three parts, stored frozen for specific periods of time, and analysed by flow cytometry for procoagulant activity immediately after thaw or following post-thaw storage for 24 h at 4 °C. Donors’ haematologic, biochemical and life-style profiles as well as circulating microparticles were analysed in parallel. Results Circulating microparticles exhibited a considerable interdonor but not intergroup variation. Fresh frozen plasma units were enriched in microparticles compared to plasma in vivo. Duration of storage significantly affected platelet- and red cell-derived microparticles. Fresh frozen plasma prepared directly from whole blood contained more residual platelets and more platelet-derived microparticles compared to fresh frozen plasma prepared from platelet-rich plasma. Consequently, there was a statistically significant difference in total, platelet- and red cell-derived microparticles between the two preparation protocols over storage time in the freezer. Preservation of the thawed units for 24 h at 4 °C did not significantly alter microparticle accumulation. Microparticle accumulation and anti-oxidant capacity of fresh frozen plasma was positively or negatively correlated, respectively, with the level of circulating microparticles in individual donors. Discussion The preparation protocol and the duration of storage in the freezer, independently and in combination, influenced the accumulation of microparticles in fresh frozen plasma units. In contrast, storage of thawed units for 24 h at 4 °C had no significant effect on the concentration of microparticles. PMID:27136430

  20. Microparticles variability in fresh frozen plasma: preparation protocol and storage time effects.

    PubMed

    Kriebardis, Anastasios G; Antonelou, Marianna H; Georgatzakou, Hara T; Tzounakas, Vassilis L; Stamoulis, Konstantinos E; Papassideri, Issidora S

    2016-05-01

    Extracellular vesicles or microparticles exhibiting procoagulant and thrombogenic activity may contribute to the haemostatic potential of fresh frozen plasma. Fresh frozen plasma was prepared from platelet-rich plasma at 20 °C (Group-1 donors) or directly from whole blood at 4 °C (Group-2 donors). Each unit was aseptically divided into three parts, stored frozen for specific periods of time, and analysed by flow cytometry for procoagulant activity immediately after thaw or following post-thaw storage for 24 h at 4 °C. Donors' haematologic, biochemical and life-style profiles as well as circulating microparticles were analysed in parallel. Circulating microparticles exhibited a considerable interdonor but not intergroup variation. Fresh frozen plasma units were enriched in microparticles compared to plasma in vivo. Duration of storage significantly affected platelet- and red cell-derived microparticles. Fresh frozen plasma prepared directly from whole blood contained more residual platelets and more platelet-derived microparticles compared to fresh frozen plasma prepared from platelet-rich plasma. Consequently, there was a statistically significant difference in total, platelet- and red cell-derived microparticles between the two preparation protocols over storage time in the freezer. Preservation of the thawed units for 24 h at 4 °C did not significantly alter microparticle accumulation. Microparticle accumulation and anti-oxidant capacity of fresh frozen plasma was positively or negatively correlated, respectively, with the level of circulating microparticles in individual donors. The preparation protocol and the duration of storage in the freezer, independently and in combination, influenced the accumulation of microparticles in fresh frozen plasma units. In contrast, storage of thawed units for 24 h at 4 °C had no significant effect on the concentration of microparticles.

  1. Metabolism, distribution and elimination of lisdexamfetamine dimesylate: open-label, single-centre, phase I study in healthy adult volunteers.

    PubMed

    Krishnan, Suma M; Pennick, Michael; Stark, Jeffrey G

    2008-01-01

    Attention-deficit/hyperactivity disorder (ADHD) in children often persists into adulthood and is potentially associated with significant social and occupational impairments. It is important to understand the effects of pharmacological treatments of ADHD in adults. This study aimed to assess the absorption, metabolism and elimination of lisdexamfetamine dimesylate in normal, healthy adult subjects following a single oral dose. A secondary objective was to assess the safety and tolerability of treatment. In an open-label, single-centre study, six healthy adult volunteers aged 22-52 years received a single oral 70 mg dose of (14)C-radiolabelled lisdexamfetamine dimesylate in solution following a 10-hour fast. Blood samples drawn pre-dose and at time points up to 120 hours post-dose were used for plasma pharmacokinetic analysis of the active d-amphetamine and the intact parent compound lisdexamfetamine dimesylate. Recovery of radioactivity was determined by liquid scintillation counting of blood samples (whole blood and plasma), urine samples and faecal samples collected pre-dose and at designated time points up to 120 hours post-dose. Urine samples were also analysed for the presence of amphetamine-derived metabolites. Safety was assessed by adverse event reporting, changes in physical findings, vital sign measurements, ECG measurements, and clinical laboratory test results. For intact lisdexamfetamine dimesylate, the median time to reach maximum plasma drug concentration (t(max)) was 1.00 hour, and the mean maximum plasma drug concentration (C(max)) was 58.2 +/- 28.1 ng/mL. Intact lisdexamfetamine dimesylate exhibited modest systemic exposure (area under the drug concentration-time curve from time 0 to infinity [AUC(infinity)] 67.04 +/- 18.94 ng . h/mL), and rapid elimination (mean apparent terminal elimination half-life [t((1/2)beta)] 0.47 hours). For d-amphetamine, the median t(max) was 3.00 hours, and the mean C(max) was 80.3 +/- 11.8 ng/mL. The AUC(infinity) of d-amphetamine was 1342 +/- 216.9 ng . h/mL, and elimination occurred as a first-order process. The t((1/2)beta) of d-amphetamine was 10.39 hours. Peaks consistent with amphetamine and hippuric acid were identified in urine samples by high-performance liquid chromatography radioactive profiling. Relative to dose administered, 41.5% was recovered in urine as d-amphetamine, 24.8% as hippuric acid and 2.2% as intact lisdexamfetamine dimesylate. Less than 0.3% of the administered dose was recovered in the faeces. During the 0- to 48-hour urine samples, no unexpected adverse events or clinically significant laboratory, ECG or physical examination findings related to the study medication were observed. Following a single 70 mg oral dose, lisdexamfetamine dimesylate was quickly absorbed, extensively metabolized to d-amphetamine and its derivatives, and rapidly eliminated. Systemic exposure to d-amphetamine was approximately 20-fold higher than systemic exposure to intact lisdexamfetamine dimesylate in healthy adults. Lisdexamfetamine dimesylate, administered as a single 70 mg dose, was generally well tolerated in this study.

  2. Research methods of plasma stream interaction with heat-resistant materials

    NASA Astrophysics Data System (ADS)

    Tyuftyaev, A. S.; Gadzhiev, M. Kh; Sargsyan, M. A.; Chinnov, V. F.; Demirov, N. A.; Kavyrshin, D. I.; Ageev, A. G.; Khromov, M. A.

    2016-11-01

    An experimental automated system was designed and constructed for studying the parameters and characteristics of non-stationary interacting system high-enthalpy-plasma stream-investigated sample: enthalpy of plasma in the incident stream; speed and temperature of plasma stream; temperature of electrons and heavy particles, ionic composition and their spatial distribution; heat flux incident on the sample (kW/cm2); surface temperature of the sample; ablation of the sample material, and others. Measurements of achievable plasma heat flux levels are carried out by calorimetry of plasma streams incident on the surface of multisection copper calorimeter. Determination of acceleration characteristics for profiled plasma torch nozzle, as well as the gas flow rate is produced by measuring the total pressure using the Pitot tube. Video visualization of interacting system is carried out using synchronized high-speed cameras. Micropyrometry of the selected zone on the sample surface is carried out by high-speed, three-wavelength pyrometer. To measure the rate of mass loss of the sample, in addition to the weighing method of evaluation the methods of laser knife and two-position stereoscopy are used. Plasma and sample emission characteristics are performed with two separate spectrometers.

  3. The potential of tumor-derived exosomes for noninvasive cancer monitoring

    PubMed Central

    Whiteside, Theresa L.

    2016-01-01

    Tumor-derived exosomes (TEXs) are emerging as a new type of cancer biomarker. TEXs are membrane-bound, virus-size vesicles of endocytic origin present in all body fluids of cancer patients. Based on the expanding albeit incomplete knowledge of their biogenesis, secretion by tumor cells and cancer cell-specific molecular and genetic contents, TEXs are viewed as promising, clinically-relevant surrogates of cancer progression and response to therapy. Preliminary proteomic, genetic and functional profiling of tumor cell-derived or cancer plasma-derived exosomes confirms their unique characteristics. Alterations in protein or nucleic acid profiles of exosomes in plasma of cancer patients responding to therapies appear to correlate with clinical endpoints. However, methods for TEX isolation and separation from the bulk of human plasma-derived exosomes are not yet established and their role as biomarkers remains to be confirmed. Further development and validation of TEXs as noninvasive, liquid equivalents of tumor biopsies are necessary to move this effort forward. PMID:26289602

  4. The potential of tumor-derived exosomes for noninvasive cancer monitoring.

    PubMed

    Whiteside, Theresa L

    2015-01-01

    Tumor-derived exosomes (TEX) are emerging as a new type of cancer biomarker. TEX are membrane-bound, virus-size vesicles of endocytic origin present in all body fluids of cancer patients. Based on the expanding albeit incomplete knowledge of their biogenesis, secretion by tumor cells and cancer cell-specific molecular and genetic contents, TEX are viewed as promising, clinically-relevant surrogates of cancer progression and response to therapy. Preliminary proteomic, genetic and functional profiling of tumor cell-derived or cancer plasma-derived exosomes confirms their unique characteristics. Alterations in protein or nucleic acid profiles of exosomes in plasma of cancer patients responding to therapies appear to correlate with clinical endpoints. However, methods for TEX isolation and separation from the bulk of human plasma-derived exosomes are not yet established and their role as biomarkers remains to be confirmed. Further development and validation of TEX as noninvasive, liquid equivalents of tumor biopsies are necessary to move this effort forward.

  5. Colloid osmotic pressure and extravasation of plasma proteins following infusion of Ringer's acetate and hydroxyethyl starch 130/0.4.

    PubMed

    Zdolsek, J H; Bergek, C; Lindahl, T L; Hahn, R G

    2015-11-01

    During fluid infusion therapy, plasma proteins are diluted and leak from the intravascular space, which alters the colloid osmotic pressure (COP) and potentially affects coagulation. We hypothesised that acetated Ringer's and starch solution, alone or in combination, influence these mechanisms differently. On different occasions, 10 male volunteers were infused with 20 ml/kg acetated Ringer's and 10 ml/kg 6% hyroxyethyl starch 130/0.4 (Voluven(®) ) alone or in combination (first with starch solution followed by Ringer's solution). Blood samples were collected every 30-min for measurements of COP, blood haemoglobin, platelets, and plasma concentrations of albumin, immunoglobulins (IgG and IgM), coagulation factor VII (FVII), fibrinogen, cystatin C, activated partial thromboplastin time (APTT) and prothrombin international normalised ratio (PT-INR). Changes were compared with the haemoglobin-derived plasma dilution. The COP increased by 8.4% (SD 3) with starch and decreased by 26.2% (7.9) with Ringer's. These infusions diluted the plasma by 23.4% (5.3) and 18.7% (4.9) respectively. The COP changes in the combined experiment followed the same pattern as the individual infusions. Albumin and IgG changes in excess of the plasma dilution were very subtle. The intravascular contents of the IgM and platelets decreased, whereas FVII, fibrinogen and cystatin C increased. PT-INR increased by 1/3 of the plasma dilution, whereas changes in APTT did not correlate with the plasma dilution. The starch increased COP and only minor capillary leak occurred in healthy volunteers. The fluid-induced plasma dilution correlated with mild impairment of the extrinsic coagulation pathway but not of the intrinsic pathway. © 2015 The Acta Anaesthesiologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  6. Serum samples can be substituted by plasma samples for the diagnosis of paratuberculosis.

    PubMed

    Goodridge, Amador; Correa, Ricardo; Castro, Paul; Escobar, Cecilia; de Waard, Jacobus H

    2013-10-01

    Employing plasma samples rather than serum samples for serological paratuberculosis diagnosis is practical, especially when bovine TB is assessed in the same cattle herd with the gamma interferon bovine avian (IFN-γ BA) test. We demonstrate that antibody titers in serum and plasma samples, utilizing the PARACHECK(®) ELISA kit, are highly comparable (Cohen's kappa test, k=0.955). We conclude that serum can be replaced with plasma in this commercially available antibody detection assay resulting in working hour savings for sampling and blood sample work-up and cost reductions for materials and sample storage. Copyright © 2013 Elsevier B.V. All rights reserved.

  7. Influence of storage conditions on in vitro stability of atrial natriuretic peptide and of anesthesia on plasma atrial natriuretic peptide concentration in cats.

    PubMed

    Heishima, Yasuhiro; Hori, Yasutomo; Chikazawa, Seishiro; Kanai, Kazutaka; Hoshi, Fumio; Itoh, Naoyuki

    2016-08-01

    OBJECTIVE To investigate the in vitro stability of atrial natriuretic peptide (ANP) in plasma samples under various storage conditions and the influence of anesthesia on plasma ANP concentration in cats. ANIMALS 1 cat with congestive heart failure and 5 healthy adult mixed-breed cats. PROCEDURES A plasma sample from the cat with heart failure was serially diluted, and dilutional parallelism of ANP concentration was evaluated. Plasma samples containing aprotinin or serum samples from the 5 healthy cats were kept at room temperature (27°C) for ≤ 12 hours. Plasma samples from the same healthy cats were stored at -70°, -20°, or 4°C for ≤ 14 days. Plasma samples were obtained from the healthy cats before and during isoflurane anesthesia. Plasma ANP concentrations were measured at a commercial laboratory by use of a human ANP chemiluminescence assay. RESULTS Intra- and interassay coefficients of variation were 1.5% and 2.5%, respectively, and dilutional parallelism was established. Although ANP concentration decreased by 82.4 ± 13.6% (mean ± SD) after sample storage for 12 hours at room temperature, this decrease was prevented by aprotinin. Plasma ANP concentrations were stable for 7 days at -20°C and for 14 days at -70°C. However, concentrations decreased markedly to 57.6 ± 6.9% at -20°C and to 18.0 ± 3.0% at 4°C after 14 days. Plasma ANP concentration decreased significantly in cats during anesthesia and was correlated with blood pressure. CONCLUSIONS AND CLINICAL RELEVANCE Results suggested that aprotinin should be added routinely in preparation of plasma samples from cats for measurement of ANP concentration, and those samples, if stored, should be frozen immediately at ≤ -20°C. General anesthesia or systemic blood pressure may affect plasma ANP concentration in cats.

  8. The presence of seminal plasma, especially derived from stallion semen, helps preserve chilled Asian elephant (Elephas maximus) sperm motility.

    PubMed

    Pinyopummin, A; Mahasawangkul, S; Kornkaewrat, K; Rattanapirom, S; Leartsang, W; Kitkha, S

    2017-08-01

    The effects of seminal plasma (SP), derived from autologous, homologous and heterologous species (stallion, boar and dog) on chilled Asian elephant sperm quality, were determined. Semen was collected from eight males and samples with ≥30% motile spermatozoa were used in the study. Semen was diluted with Tris-glucose-egg yolk extender, supplemented with different SP types and preserved at 4°C for 48 hr. Experiment 1 (n = 31), showed that the presence of SP (autologous) helped to preserve sperm quality in terms of sperm motility and acrosome integrity (p < .05). Homologous SP did not result in better sperm quality than autologous SP. Heterologous SP from stallion provided higher sperm motility and velocities compared to autologous SP (p < .05). Experiment 2 (n = 14) determined the effect of different SP from four stallions. All stallion SP gave higher (p < .05) results for motile spermatozoa and sperm velocities than autologous SP. In conclusion, the presence of SP helps preserve Asian elephant sperm quality and stallion SP supports the motility of Asian elephant spermatozoa during cold storage. © 2016 Blackwell Verlag GmbH.

  9. Inductively Coupled Plasma Optical Emission Spectrometry for Rare Earth Elements Analysis

    NASA Astrophysics Data System (ADS)

    He, Man; Hu, Bin; Chen, Beibei; Jiang, Zucheng

    2017-01-01

    Inductively coupled plasma optical emission spectrometry (ICP-OES) merits multielements capability, high sensitivity, good reproducibility, low matrix effect and wide dynamic linear range for rare earth elements (REEs) analysis. But the spectral interference in trace REEs analysis by ICP-OES is a serious problem due to the complicated emission spectra of REEs, which demands some correction technology including interference factor method, derivative spectrum, Kalman filtering algorithm and partial least-squares (PLS) method. Matrix-matching calibration, internal standard, correction factor and sample dilution are usually employed to overcome or decrease the matrix effect. Coupled with various sample introduction techniques, the analytical performance of ICP-OES for REEs analysis would be improved. Compared with conventional pneumatic nebulization (PN), acid effect and matrix effect are decreased to some extent in flow injection ICP-OES, with higher tolerable matrix concentration and better reproducibility. By using electrothermal vaporization as sample introduction system, direct analysis of solid samples by ICP-OES is achieved and the vaporization behavior of refractory REEs with high boiling point, which can easily form involatile carbides in the graphite tube, could be improved by using chemical modifier, such as polytetrafluoroethylene and 1-phenyl-3-methyl-4-benzoyl-5-pyrazone. Laser ablation-ICP-OES is suitable for the analysis of both conductive and nonconductive solid samples, with the absolute detection limit of ng-pg level and extremely low sample consumption (0.2 % of that in conventional PN introduction). ICP-OES has been extensively employed for trace REEs analysis in high-purity materials, and environmental and biological samples.

  10. Evaluation of two platelet-rich plasma processing methods and two platelet-activation techniques for use in llamas and alpacas.

    PubMed

    Semevolos, Stacy A; Youngblood, Cori D; Grissom, Stephanie K; Gorman, M Elena; Larson, Maureen K

    2016-11-01

    OBJECTIVE To evaluate 2 processing methods (commercial kit vs conical tube centrifugation) for preparing platelet rich plasma (PRP) for use in llamas and alpacas. SAMPLES Blood samples (30 mL each) aseptically collected from 6 healthy llamas and 6 healthy alpacas. PROCEDURES PRP was prepared from blood samples by use of a commercial kit and by double-step conical tube centrifugation. A CBC was performed for blood and PRP samples. Platelets in PRP samples were activated by means of a freeze-thaw method with or without 23mM CaCl 2 , and concentrations of platelet-derived growth factor-BB and transforming growth factor-β 1 were measured. Values were compared between processing methods and camelid species. RESULTS Blood CBC values for llamas and alpacas were similar. The commercial kit yielded a significantly greater degree of platelet enrichment (mean increase, 8.5 fold vs 2.8 fold) and WBC enrichment (mean increase, 3.7 fold vs 1.9 fold) than did conical tube centrifugation. Llamas had a significantly greater degree of platelet enrichment than alpacas by either processing method. No difference in WBC enrichment was identified between species. Concentrations of both growth factors were significantly greater in PRP samples obtained by use of the commercial kit versus those obtained by conical tube centrifugation. CONCLUSIONS AND CLINICAL RELEVANCE For blood samples from camelids, the commercial kit yielded a PRP product with a higher platelet and WBC concentration than achieved by conical tube centrifugation. Optimal PRP platelet and WBC concentrations for various applications need to be determined for llamas and alpacas.

  11. Three-dimensional structure and cytokine distribution of platelet-rich fibrin.

    PubMed

    Bai, Meng-Yi; Wang, Ching-Wei; Wang, Jyun-Yi; Lin, Ming-Fang; Chan, Wing P

    2017-02-01

    Previous reports have revealed that several cytokines (including platelet-derived growth factor-BB, transforming growth factors-β1 and insulin-like growth factor-1) can enhance the rate of bone formation and synthesis of extracellular matrix in orthopaedics or periodontology. This study aimed to determine the concentration of cytokines within platelet-rich fibrin microstructures and investigate whether there are differences in the different portions of platelet-rich fibrin, which has implications for proper clinical use of platelet-rich fibrin gel. Whole blood was obtained from six New Zealand rabbits (male, 7 to 39 weeks old, weight 2.7-4 kg); it was then centrifuged for preparation of platelet-rich fibrin gels and harvest of plasma. The resultant platelet-rich fibrin gels were used for cytokine determination, histological analyses and scanning electron microscopy. All plasmas obtained were subject to the same cytokine determination assays for the purpose of comparison. Cytokines platelet-derived growth factor-BB and transforming growth factor-β1 formed concentration gradients from high at the red blood cell end of the platelet-rich fibrin gel (p=1.88×10-5) to low at the plasma end (p=0.19). Insulin-like growth factor-1 concentrations were similar at the red blood cell and plasma ends. The porosities of the platelet-rich fibrin samples taken in sequence from the red blood cell end to the plasma end were 6.5% ± 4.9%, 24.8% ± 7.5%, 30.3% ± 8.5%, 41.4% ± 12.3%, and 40.3% ± 11.7%, respectively, showing a gradual decrease in the compactness of the platelet-rich fibrin network. Cytokine concentrations are positively associated with platelet-rich fibrin microstructure and portion in a rabbit model. As platelet-rich fibrin is the main entity currently used in regenerative medicine, assessing cytokine concentration and the most valuable portion of PRF gels is essential and recommended to all physicians.

  12. Longitudinal Analysis of Cerebrospinal Fluid and Plasma HIV-1 Envelope Sequences Isolated From a Single Donor with HIV Asymptomatic Neurocognitive Impairment

    PubMed Central

    Vázquez-Santiago, Fabián; García, Yashira; Rivera-Román, Ivelisse; Noel, Richard J.; Wojna, Valerie; Meléndez, Loyda M.; Rivera-Amill, Vanessa

    2015-01-01

    Objective Combined antiretroviral treatment (cART) has changed the clinical presentation of HIV-associated neurocognitive disorders (HAND) to that of the milder forms of the disease. Asymptomatic neurocognitive impairment (ANI) is now more prevalent and is associated with increased morbidity and mortality risk in HIV-1–infected people. HIV-1 envelope (env) genetic heterogeneity has been detected within the central nervous system (CNS) of individuals with ANI. Changes within env determine co-receptor use, cellular tropism, and neuropathogenesis. We hypothesize that compartmental changes are associated with HIV-1 env C2V4 during ANI and sought to analyze paired HIV-1 env sequences from plasma and cerebrospinal fluid (CSF) of a female subject undergoing long-term cART. Methods Paired plasma and CSF samples were collected at 12-month intervals and HIV-1 env C2V4 was cloned and sequenced. Results Phylogenetic analysis of paired samples consistently showed genetic variants unique to the CSF. Phenotypic prediction showed CCR5 (R5) variants for all CSF-derived sequences and showed minor X4 variants (or dual-tropic) in the plasma at later time points. Viral compartmentalization was evident throughout the study, suggesting that the occurrence of distinctive env strains may contribute to the neuropathogenesis of HAND. Conclusions Our study provides new insights about the genetic characteristics within the C2V4 of HIV-1 env that persist after long-term cART and during the course of persistent ANI. PMID:26167513

  13. Vitamin B2, vitamin B12 and total homocysteine status in children and their associations with dietary intake of B-vitamins from different food groups: the Healthy Growth Study.

    PubMed

    Manios, Yannis; Moschonis, George; Dekkers, Renske; Mavrogianni, Christina; Grammatikaki, Eva; van den Heuvel, Ellen

    2017-02-01

    To examine the associations between the dietary intakes of certain B-vitamins from different food sources with the relevant plasma status indices in children. A representative subsample of 600 children aged 9-13 years from the Healthy Growth Study was selected. Dietary intakes of vitamins B 2 , B 12 , B 6 and folate derived from different food sources were estimated. Plasma levels of vitamin B 2 (or riboflavin), methylmalonic acid (MMA) and total homocysteine (tHcy) were also measured. Plasma concentrations of vitamin B 2 below 3 μg/L were found in 22.8 % of the children. Children in the lower quartile of dietary vitamin B 2 intake were found to have the lowest plasma vitamin B 2 levels compared to children in the upper three quartiles (5.06 ± 7.63 vs. 6.48 ± 7.88, 6.34 ± 7.63 and 6.05 ± 4.94 μg/L respectively; P = 0.003). Regarding vitamin B 12 children in the lower quartile of dietary intake had higher mean plasma tHcy levels compared to children in the upper two quartiles, respectively (6.00 ± 1.79 vs. 5.41 ± 1.43 and 5.46 ± 1.64 μmol/L; P = 0.012). Positive linear associations were observed between plasma vitamin B 2 levels and dietary vitamin B 2 derived from milk and fruits (β = 0.133; P = 0.001 and β = 0.086; P = 0.037). Additionally, nonlinear associations were also observed between plasma vitamin B 2 levels and vitamin B 2 derived from red meat, as well as between tHcy levels and vitamins B 12 and B 6 derived from milk; vitamins B 12 , B 6 and folate derived from cereal products and folate derived from fruits. A considerably high prevalence of poor plasma vitamin B 2 status was observed in children. The intake of milk, fruits and cereals was associated with more favorable tHcy levels, while the intake of milk and fruits with more favorable plasma B2 levels. However, these findings need to be further confirmed from controlled dietary intervention studies examining the modulation of biomarkers of B-vitamins.

  14. Chemical Analysis of Suspected Unrecorded Alcoholic Beverages from the States of São Paulo and Minas Gerais, Brazil

    PubMed Central

    Soares Neto, Julino Assunção Rodrigues

    2015-01-01

    Our study analyzed 152 samples of alcoholic beverages collected from the states of São Paulo and Minas Gerais, Brazil, using gas chromatography with flame ionization detection (GC-FID) and mass spectrometry (GC-MS), Fourier transform infrared spectroscopy (FT-IR), and inductively coupled plasma atomic emission spectrometry (ICP-AES). The methanol content varied from 20 to 180 ppm in 28 samples, and the limit of the accepted level of 200 ppm was exceeded in only one sample. High content of cyanide derivatives and ethyl carbamate, above the accepted level of 150 ppb, was observed in 109 samples. Carbonyl compounds were also observed in 111 samples, showing hydroxy 2-propanone, 4-methyl-4-hepten-3-one, furfural, and 2-hydroxyethylcarbamate as main constituents. Copper was found at concentrations above 5 ppm in 26 samples; the maximum value observed was 28 ppm. This work evaluated the human health risk associated with the poor quality of suspected unrecorded alcohols beverages. PMID:26495155

  15. Finite temperature static charge screening in quantum plasmas

    NASA Astrophysics Data System (ADS)

    Eliasson, B.; Akbari-Moghanjoughi, M.

    2016-07-01

    The shielding potential around a test charge is calculated, using the linearized quantum hydrodynamic formulation with the statistical pressure and Bohm potential derived from finite temperature kinetic theory, and the temperature effects on the force between ions is assessed. The derived screening potential covers the full range of electron degeneracy in the equation of state of the plasma electrons. An attractive force between shielded ions in an arbitrary degenerate plasma exists below a critical temperature and density. The effect of the temperature on the screening potential profile qualitatively describes the ion-ion bound interaction strength and length variations. This may be used to investigate physical properties of plasmas and in molecular-dynamics simulations of fermion plasma. It is further shown that the Bohm potential including the kinetic corrections has a profound effect on the Thomson scattering cross section in quantum plasmas with arbitrary degeneracy.

  16. Development and Validation of a High Pressure Liquid Chromatography-UV Method for the Determination of Treosulfan and Its Epoxy Metabolites in Human Plasma and Its Application in Pharmacokinetic Studies.

    PubMed

    Koyyalamudi, Sundar R; Kuzhiumparambil, Unnikrishnan; Nath, Christa E; Byrne, Jennifer A; Fraser, Christopher J; O'Brien, Tracey A; Earl, John W; Shaw, Peter J

    2016-03-01

    Treosulfan (l-threitol-1,4-di-methanesulfonate) is a prodrug of a bifunctional alkylating agent that is being used increasingly in pediatric bone marrow transplantation regimens. The activation pathway is a complex reaction, which consists of two consecutive reactions leading to epoxybutane derivatives which are responsible for DNA alkylation. A simple, sensitive high performance liquid chromatography method for the determination of the sum of treosulfan and its epoxy metabolites by UV detection after derivatization with sodium diethyldithiocarbamate in human plasma was developed and validated. Plasma samples containing treosulfan and epoxy metabolites were converted into thiocarbamate derivative with 10% sodium diethyldithiocarbamate. Dinitrobiphenyl was used as an internal standard. The analysis was carried out using a reversed phase C18 column with a mobile phase consisting of methanol-water (65:35, v/v) at a flow rate of 1 mL/min. The eluent was monitored at 254 nm. The standard calibration curve was established between 2.5 and 50 µg/mL, with a correlation coefficient of 0.9987. Intra- and interday precision and accuracy of the method was <8% and met the analytical criteria. Pharmacokinetic parameters were determined in six children who received intravenous treosulfan (dose range 12-24 g/m(2)) in combination with fludarabine prior to blood or marrow transplantation. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  17. Multiplex Preamplification of Serum DNA to Facilitate Reliable Detection of Extremely Rare Cancer Mutations in Circulating DNA by Digital PCR.

    PubMed

    Jackson, Jennifer B; Choi, Daniel S; Luketich, James D; Pennathur, Arjun; Ståhlberg, Anders; Godfrey, Tony E

    2016-03-01

    Tumor-specific mutations can be identified in circulating, cell-free DNA in plasma or serum and may serve as a clinically relevant alternative to biopsy. Detection of tumor-specific mutations in the plasma, however, is technically challenging. First, mutant allele fractions are typically low in a large background of wild-type circulating, cell-free DNA. Second, the amount of circulating, cell-free DNA acquired from plasma is also low. Even when using digital PCR (dPCR), rare mutation detection is challenging because there is not enough circulating, cell-free DNA to run technical replicates and assay or instrument noise does not easily allow for mutation detection <0.1%. This study was undertaken to improve on the robustness of dPCR for mutation detection. A multiplexed, preamplification step using a high-fidelity polymerase before dPCR was developed to increase total DNA and the number of targets and technical replicates that can be assayed from a single sample. We were able to detect multiple cancer-relevant mutations within tumor-derived samples down to 0.01%. Importantly, the signal/noise ratio was improved for all preamplified targets, allowing for easier discrimination of low-abundance mutations against false-positive signal. Furthermore, we used this protocol on clinical samples to detect known, tumor-specific mutations in patient sera. This study provides a protocol for robust, sensitive detection of circulating tumor DNA for future clinical applications. Copyright © 2016 American Society for Investigative Pathology and the Association for Molecular Pathology. Published by Elsevier Inc. All rights reserved.

  18. Human biomonitoring of aluminium after a single, controlled manual metal arc inert gas welding process of an aluminium-containing worksheet in nonwelders.

    PubMed

    Bertram, Jens; Brand, Peter; Hartmann, Laura; Schettgen, Thomas; Kossack, Veronika; Lenz, Klaus; Purrio, Ellwyn; Reisgen, Uwe; Kraus, Thomas

    2015-10-01

    Several existing field studies evaluate aluminium welding works but no thoroughly controlled exposure scenario for welding fume has been described yet. This study provides information about the uptake and elimination of aluminium from welding fumes under controlled conditions. In the Aachen Workplace Simulation Laboratory, we are able to generate welding fumes of a defined particle mass concentration. We exposed 12, until then occupationally unexposed participants with aluminium-containing welding fumes of a metal inert gas (MIG) welding process of a total dust mass concentration of 2.5 mg/m(3) for 6 h. Room air filter samples were collected, and the aluminium concentration in air derived. Urine and plasma samples were collected directly before and after the 6-h lasting exposure, as well as after 1 and 7 days. Human biomonitoring methods were used to determine the aluminium content of the samples with high-resolution continuum source atomic absorption spectrometry. Urinary aluminium concentrations showed significant changes after exposure compared to preexposure levels (mean t(1) (0 h) 13.5 µg/L; mean t(2) (6 h) 23.5 µg/L). Plasma results showed the same pattern but pre-post comparison did not reach significance. We were able to detect a significant increase of the internal aluminium burden of a single MIG aluminium welding process in urine, while plasma failed significance. Biphasic elimination kinetic can be observed. The German BAT of 60 µg/g creatinine was not exceeded, and urinary aluminium returned nearly to baseline concentrations after 7 days.

  19. Development and validation of an LC-MS/MS method for the toxicokinetic study of deoxynivalenol and its acetylated derivatives in chicken and pig plasma.

    PubMed

    Broekaert, N; Devreese, M; De Mil, T; Fraeyman, S; De Baere, S; De Saeger, S; De Backer, P; Croubels, S

    2014-11-15

    This study aims to develop an LC-MS/MS method allowing the determination of 3-acetyl-deoxynivalenol, 15-acetyl-deoxynivalenol, deoxynivalenol and its main in vivo metabolite, deepoxy-deoxynivalenol, in broiler chickens and pigs. These species have a high exposure to these toxins, given their mainly cereal based diet. Several sample cleanup strategies were tested and further optimized by means of fractional factorial designs. A simple and straightforward sample preparation method was developed consisting out of a deproteinisation step with acetonitrile, followed by evaporation of the supernatant and reconstitution in water. The method was single laboratory validated according to European guidelines and found to be applicable for the intended purpose, with a linear response up to 200ngml(-1) and limits of quantification of 0.1-2ngml(-1). As a proof of concept, biological samples from a broiler chicken that received either deoxynivalenol, 3- or 15-acetyl-deoxynivalenol were analyzed. Preliminary results indicate nearly complete hydrolysis of 3-acetyl-deoxynivalenol to deoxynivalenol; and to a lesser extent of 15-acetyl-deoxynivalenol to deoxynivalenol. No deepoxy-deoxynivalenol was detected in any of the plasma samples. The method will be applied to study full toxicokinetic properties of deoxynivalenol, 3-acetyl-deoxynivalenol and 15-acetyl-deoxynivalenol in broiler chickens and pigs. Copyright © 2014 Elsevier B.V. All rights reserved.

  20. Plasma glial cell line-derived neurotrophic factor in patients with major depressive disorder: a preliminary study.

    PubMed

    Lee, Bun-Hee; Hong, Jin-Pyo; Hwang, Jung-A; Na, Kyoung-Sae; Kim, Won-Joong; Trigo, Jose; Kim, Yong-Ku

    2016-02-01

    Some clinical studies have reported reduced peripheral glial cell line-derived neurotrophic factor (GDNF) level in elderly patients with major depressive disorder (MDD). We verified whether a reduction in plasma GDNF level was associated with MDD. Plasma GDNF level was measured in 23 healthy control subjects and 23 MDD patients before and after 6 weeks of treatment. Plasma GDNF level in MDD patients at baseline did not differ from that in healthy controls. Plasma GDNF in MDD patients did not differ significantly from baseline to the end of treatment. GDNF level was significantly lower in recurrent-episode MDD patients than in first-episode patients before and after treatment. Our findings revealed significantly lower plasma GDNF level in recurrent-episode MDD patients, although plasma GDNF levels in MDD patients and healthy controls did not differ significantly. The discrepancy between our study and previous studies might arise from differences in the recurrence of depression or the ages of the MDD patients.

  1. Development of biomonitoring equivalents for barium in urine and plasma for interpreting human biomonitoring data.

    PubMed

    Poddalgoda, Devika; Macey, Kristin; Assad, Henry; Krishnan, Kannan

    2017-06-01

    The objectives of the present work were: (1) to assemble population-level biomonitoring data to identify the concentrations of urinary and plasma barium across the general population; and (2) to derive biomonitoring equivalents (BEs) for barium in urine and plasma in order to facilitate the interpretation of barium concentrations in the biological matrices. In population level biomonitoring studies, barium has been measured in urine in the U.S. (NHANES study), but no such data on plasma barium levels were identified. The BE values for plasma and urine were derived from U.S. EPA's reference dose (RfD) of 0.2 mg/kg bw/d, based on a lower confidence limit on the benchmark dose (BMDL 05 ) of 63 mg/kg bw/d. The plasma BE (9 μg Ba/L) was derived by regression analysis of the near-steady-state plasma concentrations associated with the administered doses in animals exposed to barium chloride dihydrate in drinking water for 2-years in a NTP study. Using a human urinary excretion fraction of 0.023, a BE for urinary barium (0.19 mg/L or 0.25 mg/g creatinine) was derived for US EPA's RfD. The median and the 95 th percentile barium urine concentrations of the general population in U.S. are below the BE determined in this study, indicating that the population exposure to inorganic barium is expected to be below the exposure guidance value of 0.2 mg/kg bw/d. Copyright © 2017 The Author(s). Published by Elsevier Inc. All rights reserved.

  2. Comparative performance of high-density oligonucleotide sequencing and dideoxynucleotide sequencing of HIV type 1 pol from clinical samples.

    PubMed

    Günthard, H F; Wong, J K; Ignacio, C C; Havlir, D V; Richman, D D

    1998-07-01

    The performance of the high-density oligonucleotide array methodology (GeneChip) in detecting drug resistance mutations in HIV-1 pol was compared with that of automated dideoxynucleotide sequencing (ABI) of clinical samples, viral stocks, and plasmid-derived NL4-3 clones. Sequences from 29 clinical samples (plasma RNA, n = 17; lymph node RNA, n = 5; lymph node DNA, n = 7) from 12 patients, from 6 viral stock RNA samples, and from 13 NL4-3 clones were generated by both methods. Editing was done independently by a different investigator for each method before comparing the sequences. In addition, NL4-3 wild type (WT) and mutants were mixed in varying concentrations and sequenced by both methods. Overall, a concordance of 99.1% was found for a total of 30,865 bases compared. The comparison of clinical samples (plasma RNA and lymph node RNA and DNA) showed a slightly lower match of base calls, 98.8% for 19,831 nucleotides compared (protease region, 99.5%, n = 8272; RT region, 98.3%, n = 11,316), than for viral stocks and NL4-3 clones (protease region, 99.8%; RT region, 99.5%). Artificial mixing experiments showed a bias toward calling wild-type bases by GeneChip. Discordant base calls are most likely due to differential detection of mixtures. The concordance between GeneChip and ABI was high and appeared dependent on the nature of the templates (directly amplified versus cloned) and the complexity of mixes.

  3. Ammonia concentrations in canine whole blood, EDTA-anticoagulated whole blood, and plasma measured by use of a point-of-care ammonia meter.

    PubMed

    Odunayo, Adesola; Tobias, Karen M; Okafor, Chika C; Flatland, Bente

    2017-11-01

    OBJECTIVE To investigate the use of canine whole blood (WB) for measurement of ammonia concentration by use of a point-of-care ammonia meter and to compare results of measuring ammonia concentrations in WB, EDTA-anticoagulated WB, and plasma. ANIMALS 40 client-owned dogs. PROCEDURES A blood sample (2 mL) was obtained from each dog. One drop of WB was immediately applied to a test strip for evaluation with an ammonia meter. The remainder of the blood sample was placed in an EDTA-containing tube, and 1 drop of EDTA-anticoagulated WB was applied to a test strip. The remaining EDTA-anticoagulated WB sample was centrifuged, and the plasma was harvested and placed on ice. One drop of plasma was applied to a test strip; the remainder of the plasma sample was transported on ice and used for ammonia measurement with a reference laboratory instrument. All samples were tested within 1 hour after sample collection. Results were evaluated to detect significant differences in ammonia concentration. RESULTS Ammonia concentrations did not differ significantly between WB and EDTA-anticoagulated WB and between plasma samples measured with the meter and reference laboratory instrument. However, median ammonia concentration was significantly higher in plasma than in WB or EDTA-anti-coagulated WB. CONCLUSIONS AND CLINICAL RELEVANCE Anticoagulant-free WB was a valid sample for measurement by use of the ammonia meter. Plasma samples had higher ammonia concentrations than did WB samples. Results for each sample type should be interpreted by use of specimen- and method-specific reference intervals.

  4. The importance of sample collection when using single cytokine levels and systemic cytokine profiles as biomarkers--a comparative study of serum versus plasma samples.

    PubMed

    Tvedt, Tor Henrik Anderson; Rye, Kristin Paulsen; Reikvam, Håkon; Brenner, Annette K; Bruserud, Øystein

    2015-03-01

    Cytokines, soluble adhesion molecules and metalloproteinases can be detected in human serum or plasma samples. Such systemic levels are widely used as biomarkers in epidemiological and clinical studies. We prepared serum samples and three types of plasma samples (EDTA, heparin, citric acid) from 20 healthy individuals. The levels of 31 cytokines, four soluble adhesion molecules and eight matrix metalloproteinases were analyzed by Luminex technology. Most mediators showed detectable levels in both plasma and serum. Several mediators that can be released by platelets showed increased serum levels, especially CCL5 and CD40L, but for the other mediators the serum levels did not correlate with peripheral blood platelet counts and for these last mediators serum and plasma levels often showed strong correlations. The use of bivalirudin for anticoagulation significantly increased and citric acid combined with platelet inhibitors (ticagrelor, acetylsalicylic acid plus prostaglandin E2) did not alter plasma levels of platelet-store mediators compared with citric acid alone. The impact of sample preparation differed between mediators; for many mediators strong correlations were seen between serum and plasma levels even when absolute levels differed. Soluble adhesion molecule levels showed only minor differences between samples. Unsupervised hierarchical clustering suggested that the effect of sampling/preparation was strongest for serum and heparin plasma samples. Careful standardization of sample preparation is usually necessary when analyzing systemic mediator levels, and differences caused by sample preparation should be considered as a possible explanation if studies show conflicting results. Copyright © 2015 Elsevier B.V. All rights reserved.

  5. Measuring factor IX activity of nonacog beta pegol with commercially available one-stage clotting and chromogenic assay kits: a two-center study.

    PubMed

    Bowyer, A E; Hillarp, A; Ezban, M; Persson, P; Kitchen, S

    2016-07-01

    Essentials Validated assays are required to precisely measure factor IX (FIX) activity in FIX products. N9-GP and two other FIX products were assessed in various coagulation assay systems at two sites. Large variations in FIX activity measurements were observed for N9-GP using some assays. One-stage and chromogenic assays accurately measuring FIX activity for N9-GP were identified. Background Measurement of factor IX activity (FIX:C) with activated partial thromboplastin time-based one-stage clotting assays is associated with a large degree of interlaboratory variation in samples containing glycoPEGylated recombinant FIX (rFIX), i.e. nonacog beta pegol (N9-GP). Validation and qualification of specific assays and conditions are necessary for the accurate assessment of FIX:C in samples containing N9-GP. Objectives To assess the accuracy of various one-stage clotting and chromogenic assays for measuring FIX:C in samples containing N9-GP as compared with samples containing rFIX or plasma-derived FIX (pdFIX) across two laboratory sites. Methods FIX:C, in severe hemophilia B plasma spiked with a range of concentrations (from very low, i.e. 0.03 IU mL(-1) , to high, i.e. 0.90 IU mL(-1) ) of N9-GP, rFIX (BeneFIX), and pdFIX (Mononine), was determined at two laboratory sites with 10 commercially available one-stage clotting assays and two chromogenic FIX:C assays. Assays were performed with a plasma calibrator and different analyzers. Results A high degree of variation in FIX:C measurement was observed for one-stage clotting assays for N9-GP as compared with rFIX or pdFIX. Acceptable N9-GP recovery was observed in the low-concentration to high-concentration samples tested with one-stage clotting assays using SynthAFax or DG Synth, or with chromogenic FIX:C assays. Similar patterns of FIX:C measurement were observed at both laboratory sites, with minor differences probably being attributable to the use of different analyzers. Conclusions These results suggest that, of the reagents tested, FIX:C in N9-GP-containing plasma samples can be most accurately measured with one-stage clotting assays using SynthAFax or DG Synth, or with chromogenic FIX:C assays. © 2016 International Society on Thrombosis and Haemostasis.

  6. Canonical Descriptions of High Intensity Laser-Plasma Interaction

    NASA Astrophysics Data System (ADS)

    Le Cornu, B. J.

    The problem of laser-plasma interaction has been studied extensively in the context of inertial confinement fusion (ICF). These studies have focussed on effects like the nonlinear force, self-focusing, Rayleigh- Taylor instabilities, stimulated Brillouin scattering and stimulated Raman scattering observed in ICF schemes. However, there remains a large discrepancy between theory and experiment in the context of nuclear fusion schemes. Several authors have attempted to gain greater understanding of the physics involved by the application of standard or 'canonical' methods used in Lagrangian and Hamiltonian mechanics to the problem of plasma physics. This thesis presents a new canonical description of laser-plasma interaction based on the Podolsky Lagrangian. Finite self-energy of charged particles, incroporation of high-frequency effects and an ability to quantise are the main advantages of this new model. The nature of the Podolsky constant is also analysed in the context of plasma physics, specifically in terms of the plasma dispersion relation. A new gauge invariant expression of the energy-momentum tensor for any gauge invariant Lagrangian dependent on second order derivatives is derived for the first time. Finally, the transient and nontransient expressions of the nonlinear ponderomotive force in laser-plasma interaction are discussed and shown to be closely approximated by a canonical derivation of the electromagnetic Lagrangian, a fact that seems to have been missed in the literature.

  7. Amyloid-β efflux from the CNS into the plasma

    PubMed Central

    Roberts, Kaleigh Filisa; Elbert, Donald L.; Kasten, Tom P.; Patterson, Bruce W.; Sigurdson, Wendy C.; Connors, Rose E.; Ovod, Vitaliy; Munsell, Ling Y.; Mawuenyega, Kwasi G.; Miller-Thomas, Michelle M.; Moran, Christopher J.; Cross, Dewitte T.; Derdeyn, Colin P.; Bateman, Randall J.

    2015-01-01

    Objective The aim of this study was to measure the flux of amyloid-β (Aβ) across the human cerebral capillary bed in order to determine if transport into the blood is a significant mechanism of clearance for Aβ produced in the central nervous system (CNS). Methods Time-matched blood samples were simultaneously collected from a cerebral vein (including the sigmoid sinus, inferior petrosal sinus, and the internal jugular vein), femoral vein, and radial artery of patients undergoing Inferior Petrosal Sinus Sampling (IPSS). For each plasma sample, Aβ concentration was assessed by three assays and the venous to arterial Aβ concentration ratios were determined. Results Aβ concentration was increased by ~7.5% in venous blood leaving the CNS capillary bed compared to arterial blood, indicating efflux from the CNS into the peripheral blood (p < 0.0001). There was no difference in peripheral venous Aβ concentration compared to arterial blood concentration. Interpretation Our results are consistent with clearance of CNS-derived Aβ into the venous blood supply with no increase from a peripheral capillary bed. Modeling these results suggests that direct transport of Aβ across the blood-brain barrier accounts for ~25% of Aβ clearance, and reabsorption of cerebrospinal fluid Aβ accounts for ~25% of the total CNS Aβ clearance in humans. PMID:25205593

  8. Radioimmunoassay of a new angiotensin-converting enzyme inhibitor (perindopril) in human plasma and urine: Advantages of coupling anion-exchange column chromatography with radioimmunoassay

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Doucet, L.; De Veyrac, B.; Delaage, M.

    1990-08-01

    Perindopril (P) is a prodrug whose active metabolite perindoprilat (PT) is an antihypertensive agent which acts by inhibition of angiotensin-converting enzyme (ACE). Anti-PT antiserum was produced in a rabbit immunized against PT that was covalently linked to bovine serum albumin. The radioligand is an iodinated ({sup 125}I) derivative of PT-glycyltyrosinamide. Both the drug (PT) and the prodrug (P) are assayed in the same sample; PT is assayed as is and P is assayed after quantitative alkaline hydrolysis into PT. Certain data obtained from such assays suggest the occurrence in plasma and urine of a third immunoreactive component. A chromatographic fractionationmore » of samples allowed us to isolate a new immunoreactive metabolite which was further identified as a glucuronide of PT (PT-G). Therefore, the whole assay was carried out as follows: biological samples were fractionated by stepwise chromatography on a anion-exchange resin (the first fraction contained P, the second contained PT, and the third contained PT-G); and RIA was performed on fractions 2 and 3 as is, and on fraction 1 after alkaline hydrolysis. Performances and assessments of this method are presented together with an example of a pharmacokinetic profile.« less

  9. Determination of hydroxyurea in human plasma by HPLC-UV using derivatization with xanthydrol.

    PubMed

    Legrand, Tiphaine; Rakotoson, Marie-Georgine; Galactéros, Frédéric; Bartolucci, Pablo; Hulin, Anne

    2017-10-01

    A simple and rapid high performance liquid chromatography (HPLC) method using ultraviolet (UV) detection was developed to determine hydroxyurea (HU) concentration in plasma sample after derivatization with xanthydrol. Two hundred microliters samples were spiked with methylurea (MeU) as internal standard and proteins were precipitated by adding methanol. Derivatization of HU and MeU was immediately performed by adding 0.02M xanthydrol and 1.5M HCl in order to obtain xanthyl-derivatives of HU and MeU that can be further separated using HPLC and quantified using UV detection at 240nm. Separation was achieved using a C18 column with a mobile phase composed of 20mM ammonium acetate and acetonitrile in gradient elution mode at a flow rate of 1mL/min. The total analysis time did not exceed 18min. The method was found linear from 5 to 400μM and all validation parameters fulfilled the international requirements. Between- and within-run accuracy error ranged from -4.7% to 3.2% and precision was lower than 12.8%. This simple method requires small volume samples and can be easily implemented in most clinical laboratories to develop pharmacokinetics studies of HU and to promote its therapeutic monitoring. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Amino Acid Derivatives as Palmitoylethanolamide Prodrugs: Synthesis, In Vitro Metabolism and In Vivo Plasma Profile in Rats

    PubMed Central

    Vacondio, Federica; Bassi, Michele; Silva, Claudia; Castelli, Riccardo; Carmi, Caterina; Scalvini, Laura; Lodola, Alessio; Vivo, Valentina; Flammini, Lisa; Barocelli, Elisabetta; Mor, Marco; Rivara, Silvia

    2015-01-01

    Palmitoylethanolamide (PEA) has antinflammatory and antinociceptive properties widely exploited in veterinary and human medicine, despite its poor pharmacokinetics. Looking for prodrugs that could progressively release PEA to maintain effective plasma concentrations, we prepared carbonates, esters and carbamates at the hydroxyl group of PEA. Chemical stability (pH 7.4) and stability in rat plasma and liver homogenate were evaluated by in vitro assays. Carbonates and carbamates resulted too labile and too resistant in plasma, respectively. Ester derivatives, prepared by conjugating PEA with various amino acids, allowed to modulate the kinetics of PEA release in plasma and stability in liver homogenate. L-Val-PEA, with suitable PEA release in plasma, and D-Val-PEA, with high resistance to hepatic degradation, were orally administered to rats and plasma levels of prodrugs and PEA were measured at different time points. Both prodrugs showed significant release of PEA, but provided lower plasma concentrations than those obtained with equimolar doses of PEA. Amino-acid esters of PEA are a promising class to develop prodrugs, even if they need further chemical optimization. PMID:26053855

  11. Use of vitamin B12 in joint lavage for determination of dilution factors of canine synovial fluid.

    PubMed

    de Bruin, Tanya; de Rooster, Hilde; van Bree, Henri; Cox, Eric

    2005-11-01

    To test a modified saline (0.9% NaCl) solution joint washing (lavage) technique that includes the use of vitamin B12 as an internal marker for the evaluation of synovial fluid dilution in lavage samples from canine joints. 9 plasma samples obtained from blood samples of 9 healthy dogs and 9 synovial fluid samples aspirated from stifle joints of 9 cadaveric dogs. Photometric absorbances of 25% vitamin B12 solution, canine synovial fluid, and canine plasma were measured in a spectrophotometer to establish an optimal wavelength for analysis. Canine synovial fluid and plasma samples were mixed with the 25% vitamin B12 solution to obtain 1%, 3%, 5%, 10%, 20%, and 50% solutions of synovial fluid or plasma. Diluted synovial fluid and plasma samples were used to simulate joint lavage samples and to examine the possible interference of these substances (synovial fluid or plasma) with the absorbance of the 25% vitamin B12 solution in photometric analysis. The optimal wavelength was found to be at 550 nm. Canine synovial fluid and plasma samples did not interfere with the absorbance measurements of the 25% vitamin B12 solution up to a 50% dilution of plasma or synovial fluid. The modified saline solution joint lavage method with the use of a 25% vitamin B12 solution as an internal standard provides an accurate and reliable technique for the evaluation of synovial fluid dilution in lavage samples from canine joints.

  12. Identification in Rat Plasma and Urine by Linear Trap Quadrupole-Orbitrap Mass Spectrometry of the Metabolites of Maslinic Acid, a Triterpene from Olives.

    PubMed

    Sánchez-González, Marta; Lozano-Mena, Glòria; Parra, Andrés; Juan, M Emília; Planas, Joana M

    2015-02-04

    Maslinic acid is a natural pentacyclic triterpenoid widely distributed in edible and medicinal plants with health-promoting activities. The identification and quantification of its metabolites is a requirement for a better understanding of the biological effects of this triterpene. Therefore, maslinic acid was orally administered to Sprague-Dawley rats at a dose of 50 mg/kg of body weight. Blood and urine were withdrawn at 45 min. Samples were extracted with ethyl acetate prior to liquid chromatography-atmospheric pressure chemical ionization-linear trap quadrupole-Orbitrap (LC-APCI-LTQ-Orbitrap) analysis. Screening of plasma yielded four monohydroxylated derivatives (M1-M4), one monohydroxylated and dehydrogenated metabolite (M5), and two dihydroxylated and dehydrogenated compounds (M6 and M7). In urine, M1, M4, M5, and M6 were detected. Quantification by LC-APCI-mass spectrometry (MS) revealed maslinic acid as the prevalent compound in both plasma (81.8%) and urine (73.9%), which indicates that metabolism is low and mainly attributable to phase I reactions.

  13. LC-MS/MS quantification of next-generation biotherapeutics: a case study for an IgE binding Nanobody in cynomolgus monkey plasma.

    PubMed

    Sandra, Koen; Mortier, Kjell; Jorge, Lucie; Perez, Luis C; Sandra, Pat; Priem, Sofie; Poelmans, Sofie; Bouche, Marie-Paule

    2014-05-01

    Nanobodies(®) are therapeutic proteins derived from the smallest functional fragments of heavy chain-only antibodies. The development and validation of an LC-MS/MS-based method for the quantification of an IgE binding Nanobody in cynomolgus monkey plasma is presented. Nanobody quantification was performed making use of a proteotypic tryptic peptide chromatographically enriched prior to LC-MS/MS analysis. The validated LLOQ at 36 ng/ml was measured with an intra- and inter-assay precision and accuracy <20%. The required sensitivity could be obtained based on the selectivity of 2D LC combined with MS/MS. No analyte specific tools for affinity purification were used. Plasma samples originating from a PK/PD study were analyzed and compared with the results obtained with a traditional ligand-binding assay. Excellent correlations between the two techniques were obtained, and similar PK parameters were estimated. A 2D LC-MS/MS method was successfully developed and validated for the quantification of a next generation biotherapeutic.

  14. Urinary and plasma purine derivatives in fed and fasted llamas (Lama glama and L. guanacoe).

    PubMed

    Bakker, M L; Chen, X B; Kyle, D J; Orskov, E R; Bourke, D A

    1996-02-01

    The changes in urinary and plasma purine derivatives in response to fasting and level of feeding in llamas were examines. In one experiment, four llamas were gradually deprived of feed within 3 days and then fasted for 6 days. Daily urinary excretion of purine derivatives decreased with feed intake and leveled on the last 3 days of fasting at 177 +/- 26 mumol/kg W0.75. Allantoin and uric acid comprised 71% and 15% of total purine derivatives, respectively, in both fed and fasted states, but hypoxanthine plus xanthine increased from 9% to 36%. Plasma concentration of allantoin declined with feed intake reduction, but those of uric acid (217 mumol/l) and hypoxanthine plus xanthine (27 mumol/l) remained relatively unchanged. Concentration of uric acid was higher than that of allantoin, probably due to a high reabsorption of uric acid in renal tubules, which was measured as over 90%. In a second experiment, the four llamas were fed at 860 and 1740 g dry matter/d in a crossover design. Urinary total purine derivatives excretion responded to feed intake (10.4 vs 14.4 mmol/d), although the observed differences did not reach significance. Compared with some ruminant species, it appears that the llama resembles sheep regarding the magnitude of urinary purine derivatives excretion but is unique in maintaining a high concentration of uric acid in plasma, which could be part of the llama's adaptation to their environment.

  15. On plasma convection in Saturn's magnetosphere

    NASA Astrophysics Data System (ADS)

    Livi, Roberto

    We use CAPS plasma data to derive particle characteristics within Saturn's inner magnetosphere. Our approach is to first develop a forward-modeling program to derive 1-dimensional (1D) isotropic plasma characteristics in Saturn's inner, equatorial magnetosphere using a novel correction for the spacecraft potential and penetrating background radiation. The advantage of this fitting routine is the simultaneous modeling of plasma data and systematic errors when operating on large data sets, which greatly reduces the computation time and accurately quantifies instrument noise. The data set consists of particle measurements from the Electron Spectrometer (ELS) and the Ion Mass Spectrometer (IMS), which are part of the Cassini Plasma Spectrometer (CAPS) instrument suite onboard the Cassini spacecraft. The data is limited to peak ion flux measurements within +/-10° magnetic latitude and 3-15 geocentric equatorial radial distance (RS). Systematic errors such as spacecraft charging and penetrating background radiation are parametrized individually in the modeling and are automatically addressed during the fitting procedure. The resulting values are in turn used as cross-calibration between IMS and ELS, where we show a significant improvement in magnetospheric electron densities and minor changes in the ion characteristics due to the error adjustments. Preliminary results show ion and electron densities in close agreement, consistent with charge neutrality throughout Saturn's inner magnetosphere and confirming the spacecraft potential to be a common influence on IMS and ELS. Comparison of derived plasma parameters with results from previous studies using CAPS data and the Radio And Plasma Wave Science (RPWS) investigation yields good agreement. Using the derived plasma characteristics we focus on the radial transport of hot electrons. We present evidence of loss-free adiabatic transport of equatorially mirroring electrons (100 eV - 10 keV) in Saturn's magnetosphere between 10-19 RS and from July 1st, 2004 to . Hot electron densities peak near 9 RS and decrease radially at a rate of 1/r3, which suggests a source in the inner magnetosphere. We also observe a decrease in electron energy at a rate of 1/r3 due to the conservation of the first adiabatic invariant, consistent with radial transport through a magnetic dipole. Data from the magnetic field instrument is used to derive the magnetic moment of hot electrons which shows a constant value of 103.4 kgm2s-2 nT-1 +/-10 between 10-19 RS, indicating a loss-free adiabatic transport with minor fluctuations. Plasma transport at Saturn can occur through flux tube interchange instabilities within the magnetosphere, where cold dense plasma is transported radially outward while hot tenuous plasma from the outer magnetosphere moves radially inward. Gradient-curvature drifts cause these hot electrons leave the injection and superimpose on the ambient cold plasma, consequently forcing it to move radially outward. This implies flux-tube interchange to be the main source for hot electrons. Hot electrons are part of the plasma analysis for which CAPS was designed, while the MIMI-LEMMS instrument measures higher energy electrons. Taking into account the penetrating background radiation, we are able to derive information for these energetic particles using our plasma instruments. We present CAPS-IMS background measurements derived from plasma data and show strong correlation with high energy particle data from MIMI-LEMMS. IMS background is generated via two main processes: 1) Collisions between the instrument walls and ambient energetic particles, which cause X-rays to trigger count signals in the instrument optics, and 2) backscatter of energetic particles in the electrostatic analyzer. We quantify these effects and use the results to identify Saturn's radiation belt peaks and nadirs, and magnetospheric regions of depleted particle fluxes, or microsignatures, which are formed through interactions with moons and ring systems. Using methods described in [119] we analyze a moon microsignatures during the outbound phase of Saturn orbit insertion (2004-183) and inside the orbit of Mimas, a region of intense radiation. Using the physical characteristics and radial locations of Atlas, Prometheus, and Pandora we derive the radial diffusion coefficient to be less than 1 x10-9 and particle energies to be below 1 MeV.

  16. Bacteria-killing ability of fresh blood plasma compared to frozen blood plasma

    DOE PAGES

    Jacobs, Anne C.; Fair, Jeanne Marie

    2015-10-09

    In recent years, the bacteria-killing assay (BKA) has become a popular technique among ecoimmunologists. New variations of that assay allow researchers to use smaller volumes of blood, an important consideration for those working on small-bodied animals. However, this version of the assay requires access to a lab with a nanodrop spectrophotometer, something that may not be available in the field. One possible solution is to freeze plasma for transport; however, this assumes that frozen plasma samples will give comparable results to fresh ones. Here, we tested this assumption using plasma samples from three species of birds: chickens (Gallus gallus), ash-throatedmore » flycatchers (Myiarchus cinerascens), and western bluebirds (Sialia mexicana). Chicken plasma samples lost most or all of their bacterial killing ability after freezing. This did not happen in flycatchers and bluebirds; however, frozen plasma did not produce results comparable to those obtained using fresh plasma. Finally, we caution researchers using the BKA to use fresh samples whenever possible, and to validate the use of frozen samples on a species-by-species basis.« less

  17. Spatial-temporal diagnostics of the system of a plasma stream interacting with a surface of heat resistant material

    NASA Astrophysics Data System (ADS)

    Chinnov, V. F.; Sargsyan, M. A.; Gadzhiev, M. Kh; Khromov, M. A.; Kavyrshin, D. I.; Chistolinov, A. V.

    2018-01-01

    In an automated measuring complex using optical and spectral methods the spatial and temporal changes in the parameters and composition of nitrogen plasma jet were investigated. The plasma jet was flowing out of the nozzle of the plasma torch with 10-12 kK temperature and acting on the sample of MPG-6 graphite. Due to the heating of the sample to the temperatures of 2.5-3 kK the influence of the sublimating material of the sample on the plasma composition and temperature in the near-surface region of the sample was investigated. An original method based on the analysis of movement of optical inhomogeneities in the plasma flow was used to estimate the plasma jet velocity in the region where it interacts with the sample. The combined analysis of the results of two-positioning video recordings opens up the possibility of determining spatial-temporal distributions of the plasma jet velocities, in medium and high pressure environments, in the ranges from few to thousands of m/s and 3-15 kK temperatures.

  18. Bacteria-killing ability of fresh blood plasma compared to frozen blood plasma.

    PubMed

    Jacobs, Anne C; Fair, Jeanne M

    2016-01-01

    In recent years, the bacteria-killing assay (BKA) has become a popular technique among ecoimmunologists. New variations of that assay allow researchers to use smaller volumes of blood, an important consideration for those working on small-bodied animals. However, this version of the assay requires access to a lab with a nanodrop spectrophotometer, something that may not be available in the field. One possible solution is to freeze plasma for transport; however, this assumes that frozen plasma samples will give comparable results to fresh ones. We tested this assumption using plasma samples from three species of birds: chickens (Gallus gallus), ash-throated flycatchers (Myiarchus cinerascens), and western bluebirds (Sialia mexicana). Chicken plasma samples lost most or all of their bacterial killing ability after freezing. This did not happen in flycatchers and bluebirds; however, frozen plasma did not produce results comparable to those obtained using fresh plasma. We caution researchers using the BKA to use fresh samples whenever possible, and to validate the use of frozen samples on a species-by-species basis. Copyright © 2015 Elsevier Inc. All rights reserved.

  19. Bacteria-killing ability of fresh blood plasma compared to frozen blood plasma

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jacobs, Anne C.; Fair, Jeanne Marie

    In recent years, the bacteria-killing assay (BKA) has become a popular technique among ecoimmunologists. New variations of that assay allow researchers to use smaller volumes of blood, an important consideration for those working on small-bodied animals. However, this version of the assay requires access to a lab with a nanodrop spectrophotometer, something that may not be available in the field. One possible solution is to freeze plasma for transport; however, this assumes that frozen plasma samples will give comparable results to fresh ones. Here, we tested this assumption using plasma samples from three species of birds: chickens (Gallus gallus), ash-throatedmore » flycatchers (Myiarchus cinerascens), and western bluebirds (Sialia mexicana). Chicken plasma samples lost most or all of their bacterial killing ability after freezing. This did not happen in flycatchers and bluebirds; however, frozen plasma did not produce results comparable to those obtained using fresh plasma. Finally, we caution researchers using the BKA to use fresh samples whenever possible, and to validate the use of frozen samples on a species-by-species basis.« less

  20. Cinnamon extract regulates plasma levels of adipose-derived factors and expression of multiple genes related to carbohydrate metabolism and lipogenesis in adipose tissue of fructose-fed rats

    USDA-ARS?s Scientific Manuscript database

    We reported previously that a dietary cinnamon extract (CE) improves systemic insulin sensitivity and dyslipidemia by enhancing insulin signaling. In the present study, we examined the effects of CE on several biomarkers including plasma levels of adipose-derived adipokines, and the potential molec...

  1. Combination of plasma HA and circulating M2-like monocytes may serve as a diagnostic marker for breast cancer.

    PubMed

    Zhang, Boke; Cao, Manlin; He, Yiqing; Liu, Yiwen; Zhang, Guoliang; Yang, Cuixia; Du, Yan; Xu, Jing; Hu, Jiajie; Gao, Feng

    2017-01-01

    Background: Breast cancer (BC)-derived hyaluronan (HA) can induce the formation of M2-like tumor-associated macrophages (TAMs) in tumor context. However, little is known about the correlation between circulating M2-like monocytes and plasma HA in BC patients. This study focused on evaluating the relationship between circulating M2-like monocytes and plasma HA, and further appraised the diagnostic value of them in BC. Methods: The expression of M2-like TAMs and HA was determined in pathological tissues by immunohistochemistry. Flow cytometry was used to detect the levels of circulating CD14 + CD204 + M2-like monocytes in 81 BC patients, 45 patients with breast benign diseases, and 46 healthy subjects. The levels of HA, CEA, and CA15-3 were measured in plasma samples using chemiluminescence method. Results: M2-like TAMs and HA expressions were elevated in BC tissues compared with benign tissues. In correspondence, the frequency of circulating CD14 + CD204 + M2-like monocytes and the plasma HA levels were significantly higher in patients with BC than those in control groups. Importantly, there was a positive correlation between circulating M2-like monocytes and the plasma HA (Spearman r = 0.404, p < 0.001). Area under receiver operating characteristic curve (ROC) for the combination of circulating M2-like monocytes and HA was 0.899 (95% CI: 0.853-0.946), which was higher than the panel of CEA and CA15-3. Conclusions: The frequency of circulating CD14 + CD204 + M2-like monocytes was positively correlated to plasma HA levels. The combination of circulating CD14 + CD204 + M2-like monocytes and plasma HA could provide considerable diagnostic value in BC.

  2. In vitro storage characteristics of platelet concentrates suspended in 70% SSP+(TM) additive solution versus plasma over a 14-day storage period.

    PubMed

    Saunders, C; Rowe, G; Wilkins, K; Holme, S; Collins, P

    2011-08-01

    The non-paired two-arm study compared the in vitro storage characteristics of platelets suspended as concentrates in either 100% plasma or a mixture of additive solution (SSP+™, MacoPharma, Mouveaux, France) and autologous plasma in a 70:30 ratio over a 14-day storage period. The buffy coat-derived pooled platelet concentrates were sampled on days 1, 2, 3, 6, 8, 10 and 14 and tests performed to determine platelet morphology, function, metabolism, activation and apoptosis-like activity. Swirling remained strong (score=3) in SSP+™, whilst scores of 1 and 0 were noted for plasma units by end of storage. In contrast to units in plasma, pH levels remained above seven in SSP+™ units, increasing after day 10. Percent positive expression of CD62P was similar in both groups on day 1 (median of 54% and 56% for plasma (n=13) and SSP+™ (n=12), respectively), with SSP+™ units showing a more moderate increase in activation after day 10. A progressive decrease in mitochondrial membrane potential was evident in both groups from day 1, whilst annexin V binding was relatively stable from days 1 to 3, with median values remaining below 6%. Subsequent to this, the percentage of platelets binding annexin V increased to approximately 30% by day 14. Platelets suspended in a medium of 70:30 SSP+™ to plasma ratio performed at least as well as platelets in 100% autologous plasma for up to 10 days of storage. Further, results are suggestive of an apoptosis-like process being involved in the platelet storage lesion. © 2011 The Author(s). Vox Sanguinis © 2011 International Society of Blood Transfusion.

  3. Nicotine Metabolite Ratio (3-hydroxycotinine/cotinine) in Plasma and Urine by Different Analytical Methods and Laboratories: Implications for Clinical Implementation

    PubMed Central

    Tanner, Julie-Anne; Novalen, Maria; Jatlow, Peter; Huestis, Marilyn A.; Murphy, Sharon E.; Kaprio, Jaakko; Kankaanpää, Aino; Galanti, Laurence; Stefan, Cristiana; George, Tony P.; Benowitz, Neal L.; Lerman, Caryn; Tyndale, Rachel F.

    2015-01-01

    Background The highly genetically variable enzyme CYP2A6 metabolizes nicotine to cotinine (COT) and COT to trans-3′-hydroxycotinine (3HC). The nicotine metabolite ratio (NMR, 3HC/COT) is commonly used as a biomarker of CYP2A6 enzymatic activity, rate of nicotine metabolism, and total nicotine clearance; NMR is associated with numerous smoking phenotypes, including smoking cessation. Our objective was to investigate the impact of different measurement methods, at different sites, on plasma and urinary NMR measures from ad libitum smokers. Methods Plasma (n=35) and urine (n=35) samples were sent to eight different laboratories, which employed similar and different methods of COT and 3HC measurements to derive the NMR. We used Bland-Altman analysis to assess agreement, and Pearson correlations to evaluate associations, between NMR measured by different methods. Results Measures of plasma NMR were in strong agreement between methods according to Bland-Altman analysis (ratios 0.82–1.16) and were highly correlated (all Pearson r>0.96, P<0.0001). Measures of urinary NMR were in relatively weaker agreement (ratios 0.62–1.71) and less strongly correlated (Pearson r values of 0.66–0.98, P<0.0001) between different methods. Plasma and urinary COT and 3HC concentrations, while weaker than NMR, also showed good agreement in plasma, which was better than in urine, as was observed for NMR. Conclusions Plasma is a very reliable biological source for the determination of NMR, robust to differences in these analytical protocols or assessment site. Impact Together this indicates a reduced need for differential interpretation of plasma NMR results based on the approach used, allowing for direct comparison of different studies. PMID:26014804

  4. Preclinical examination of clofarabine in pediatric ependymoma: intratumoral concentrations insufficient to warrant further study.

    PubMed

    Patel, Yogesh T; Jacus, Megan O; Boulos, Nidal; Dapper, Jason D; Davis, Abigail D; Vuppala, Pradeep K; Freeman, Burgess B; Mohankumar, Kumarasamypet M; Throm, Stacy L; Gilbertson, Richard J; Stewart, Clinton F

    2015-05-01

    Clofarabine, a deoxyadenosine analog, was an active anticancer drug in our in vitro high-throughput screening against mouse ependymoma neurospheres. To characterize the clofarabine disposition in mice for further preclinical efficacy studies, we evaluated the plasma and central nervous system disposition in a mouse model of ependymoma. A plasma pharmacokinetic study of clofarabine (45 mg/kg, IP) was performed in CD1 nude mice bearing ependymoma to obtain initial plasma pharmacokinetic parameters. These estimates were used to derive D-optimal plasma sampling time points for cerebral microdialysis studies. A simulation of clofarabine pharmacokinetics in mice and pediatric patients suggested that a dosage of 30 mg/kg IP in mice would give exposures comparable to that in children at a dosage of 148 mg/m(2). Cerebral microdialysis was performed to study the tumor extracellular fluid (ECF) disposition of clofarabine (30 mg/kg, IP) in the ependymoma cortical allografts. Plasma and tumor ECF concentration-time data were analyzed using a nonlinear mixed effects modeling approach. The median unbound fraction of clofarabine in mouse plasma was 0.79. The unbound tumor to plasma partition coefficient (K pt,uu: ratio of tumor to plasma AUCu,0-inf) of clofarabine was 0.12 ± 0.05. The model-predicted mean tumor ECF clofarabine concentrations were below the in vitro 1-h IC50 (407 ng/mL) for ependymoma neurospheres. Thus, our results show the clofarabine exposure reached in the tumor ECF was below that associated with an antitumor effect in our in vitro washout study. Therefore, clofarabine was de-prioritized as an agent to treat ependymoma, and further preclinical studies were not pursued.

  5. Preclinical examination of clofarabine in pediatric ependymoma: Intratumoral concentrations insufficient to warrant further study

    PubMed Central

    Patel, Yogesh T.; Jacus, Megan O.; Boulos, Nidal; Dapper, Jason D.; Davis, Abigail D.; Vuppala, Pradeep K.; Freeman, Burgess B.; Mohankumar, Kumarasamypet M.; Throm, Stacy L.; Gilbertson, Richard J.; Stewart, Clinton F.

    2015-01-01

    Clofarabine, a deoxyadenosine analog, was an active anticancer drug in our in vitro high-throughput screening against mouse ependymoma neurospheres. To characterize the clofarabine disposition in mice for further preclinical efficacy studies, we evaluated the plasma and central nervous system (CNS) disposition in a mouse model of ependymoma. A plasma pharmacokinetic study of clofarabine (45 mg/kg, IP) was performed in CD1 nude mice bearing ependymoma to obtain initial plasma pharmacokinetic parameters. These estimates were used to derive D-optimal plasma sampling time-points for cerebral microdialysis studies. A simulation of clofarabine pharmacokinetics in mice and pediatric patients suggested that a dosage of 30 mg/kg, IP in mice would give exposures comparable to that in children at a dosage of 148 mg/m2. Cerebral microdialysis was performed to study the tumor extracellular fluid (ECF) disposition of clofarabine (30 mg/kg, IP) in the ependymoma cortical allografts. Plasma and tumor ECF concentration-time data were analyzed using a nonlinear mixed effects modeling approach. The median unbound fraction of clofarabine in mouse plasma was 0.79. The unbound tumor to plasma partition coefficient (Kpt,uu: ratio of tumor to plasma AUCu,0-inf) of clofarabine was 0.12±0.05. The model predicted mean tumor ECF clofarabine concentrations were below the in vitro 1-hr IC50 (407 ng/mL) for ependymoma neurospheres. Thus, our results show the clofarabine exposure reached in the tumor ECF was below that associated with an antitumor effect in our in vitro washout study. Therefore, clofarabine was de-prioritized as an agent to treat ependymoma, and further preclinical studies were not pursued. PMID:25724157

  6. The Phospholipid Linoleoylglycerophosphocholine as a Biomarker of Directly Measured Insulin Resistance

    PubMed Central

    Pérez-Matos, Maria Camila; Morales-Álvarez, Martha Catalina; Toloza, Freddy Jean Karlo; Ricardo-Silgado, Maria Laura; Mantilla-Rivas, Jose Oscar; Pinzón-Cortes, Jairo Arturo; Perez-Mayorga, Maritza; Jiménez, Elizabeth; Guevara, Edwin

    2017-01-01

    Background Plasma concentrations of some lysophospholipids correlate with metabolic alterations in humans, but their potential as biomarkers of insulin resistance (IR) is insufficiently known. We aimed to explore the association between plasma linoleoylglycerophosphocholine (LGPC) and objective measures of IR in adults with different metabolic profiles. Methods We studied 62 men and women, ages 30 to 69 years, (29% normal weight, 59% overweight, 12% obese). Participants underwent a 5-point oral glucose tolerance test (5p-OGTT) from which we calculated multiple indices of IR and insulin secretion. Fifteen participants additionally underwent a hyperinsulinemic-euglycemic clamp for estimation of insulin-stimulated glucose disposal. Plasma LGPC was determined using high performance liquid chromatography/time-of-flight mass spectrometry. Plasma LGPC was compared across quartiles defined by the IR indices. Results Mean LGPC was 15.4±7.6 ng/mL in women and 14.1±7.3 ng/mL in men. LGPC did not correlate with body mass in-dex, percent body fat, waist circumference, blood pressure, glycosylated hemoglobin, log-triglycerides, or high density lipoprotein cholesterol. Plasma LGPC concentrations was not systematically associated with any of the studied 5p-OGTT-derived IR indices. However, LGPC exhibited a significant negative correlation with glucose disposal in the clamp (Spearman r=−0.56, P=0.029). Despite not being diabetic, participants with higher plasma LGPC exhibited significantly higher post-challenge plasma glucose excursions in the 5p-OGTT (P trend=0.021 for the increase in glucose area under the curve across quartiles of plasma LGPC). Conclusion In our sample of Latino adults without known diabetes, LGPC showed potential as a biomarker of IR and impaired glucose metabolism. PMID:29199411

  7. Penetration and screening of perpendicularly launched electromagnetic waves through bounded supercritical plasma confined in multicusp magnetic field

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dey, Indranuj; Bhattacharjee, Sudeep

    2011-02-15

    The question of electromagnetic wave penetration and screening by a bounded supercritical ({omega}{sub p}>{omega} with {omega}{sub p} and {omega} being the electron-plasma and wave frequencies, respectively) plasma confined in a minimum B multicusp field, for waves launched in the k perpendicular B{sub o} mode, is addressed through experiments and numerical simulations. The scale length of radial plasma nonuniformity (|n{sub e}/({partial_derivative}n{sub e}/{partial_derivative}r)|) and magnetostatic field (B{sub o}) inhomogeneity (|B{sub o}/({partial_derivative}B{sub o}/{partial_derivative}r)|) are much smaller than the free space ({lambda}{sub o}) and guided wavelengths ({lambda}{sub g}). Contrary to predictions of plane wave dispersion theory and the Clemow-Mullaly-Allis (CMA) diagram, for a boundedmore » plasma a finite propagation occurs through the central plasma regions where {alpha}{sub p}{sup 2}={omega}{sub p}{sup 2}/{omega}{sup 2}{>=}1 and {beta}{sub c}{sup 2}={omega}{sub ce}{sup 2}/{omega}{sup 2}<<1({approx}10{sup -4}), with {omega}{sub ce} being the electron cyclotron frequency. Wave screening, as predicted by the plane wave model, does not remain valid due to phase mixing and superposition of reflected waves from the conducting boundary, leading to the formation of electromagnetic standing wave modes. The waves are found to satisfy a modified upper hybrid resonance (UHR) relation in the minimum B field and are damped at the local electron cyclotron resonance (ECR) location.« less

  8. Ameliorating effects of Mango (Mangifera indica L.) fruit on plasma ethanol level in a mouse model assessed with 1H-NMR based metabolic profiling

    PubMed Central

    Kim, So-Hyun; K. Cho, Somi; Min, Tae-Sun; Kim, Yujin; Yang, Seung-Ok; Kim, Hee-Su; Hyun, Sun-Hee; Kim, Hana; Kim, Young-Suk; Choi, Hyung-Kyoon

    2011-01-01

    The ameliorating effects of Mango (Mangifera indica L.) flesh and peel samples on plasma ethanol level were investigated using a mouse model. Mango fruit samples remarkably decreased mouse plasma ethanol levels and increased the activities of alcohol dehydrogenase and acetaldehyde dehydrogenase. The 1H-NMR-based metabolomic technique was employed to investigate the differences in metabolic profiles of mango fruits, and mouse plasma samples fed with mango fruit samples. The partial least squares-discriminate analysis of 1H-NMR spectral data of mouse plasma demonstrated that there were clear separations among plasma samples from mice fed with buffer, mango flesh and peel. A loading plot demonstrated that metabolites from mango fruit, such as fructose and aspartate, might stimulate alcohol degradation enzymes. This study suggests that mango flesh and peel could be used as resources for functional foods intended to decrease plasma ethanol level after ethanol uptake. PMID:21562641

  9. Thermal Degradation of Small Molecules: A Global Metabolomic Investigation.

    PubMed

    Fang, Mingliang; Ivanisevic, Julijana; Benton, H Paul; Johnson, Caroline H; Patti, Gary J; Hoang, Linh T; Uritboonthai, Winnie; Kurczy, Michael E; Siuzdak, Gary

    2015-11-03

    Thermal processes are widely used in small molecule chemical analysis and metabolomics for derivatization, vaporization, chromatography, and ionization, especially in gas chromatography mass spectrometry (GC/MS). In this study the effect of heating was examined on a set of 64 small molecule standards and, separately, on human plasma metabolite extracts. The samples, either derivatized or underivatized, were heated at three different temperatures (60, 100, and 250 °C) at different exposure times (30 s, 60 s, and 300 s). All the samples were analyzed by liquid chromatography coupled to electrospray ionization mass spectrometry (LC/MS) and the data processed by XCMS Online ( xcmsonline.scripps.edu ). The results showed that heating at an elevated temperature of 100 °C had an appreciable effect on both the underivatized and derivatized molecules, and heating at 250 °C created substantial changes in the profile. For example, over 40% of the molecular peaks were altered in the plasma metabolite analysis after heating (250 °C, 300s) with a significant formation of degradation and transformation products. The analysis of 64 small molecule standards validated the temperature-induced changes observed on the plasma metabolites, where most of the small molecules degraded at elevated temperatures even after minimal exposure times (30 s). For example, tri- and diorganophosphates (e.g., adenosine triphosphate and adenosine diphosphate) were readily degraded into a mono-organophosphate (e.g., adenosine monophosphate) during heating. Nucleosides and nucleotides (e.g., inosine and inosine monophosphate) were also found to be transformed into purine derivatives (e.g., hypoxanthine). A newly formed transformation product, oleoyl ethyl amide, was identified in both the underivatized and derivatized forms of the plasma extracts and small molecule standard mixture, and was likely generated from oleic acid. Overall these analyses show that small molecules and metabolites undergo significant time-sensitive alterations when exposed to elevated temperatures, especially those conditions that mimic sample preparation and analysis in GC/MS experiments.

  10. Bone marrow uptake of 99mTc-MIBI in patients with multiple myeloma.

    PubMed

    Fonti, R; Del Vecchio, S; Zannetti, A; De Renzo, A; Di Gennaro, F; Catalano, L; Califano, C; Pace, L; Rotoli, B; Salvatore, M

    2001-02-01

    In a previous study, we showed the ability of technetium-99m methoxyisobutylisonitrile (99mTc-MIBI) scan to identify active disease in patients with multiple myeloma (Eur J Nucl Med 1998; 25: 714-720). In particular, a semiquantitative score of the extension and intensity of bone marrow uptake was derived and correlated with both the clinical status of the disease and plasma cell bone marrow infiltration. In order to estimate quantitatively 99mTc-MIBI bone marrow uptake and to verify the intracellular localization of the tracer, bone marrow samples obtained from 24 multiple myeloma patients, three patients with monoclonal gammopathy of undetermined significance (MGUS) and two healthy donors were studied for in vitro uptake. After centrifugation over Ficoll-Hypaque gradient, cell suspensions were incubated with 99mTc-MIBI and the uptake was expressed as the percentage of radioactivity specifically retained within the cells. The cellular localization of the tracer was assessed by micro-autoradiography. Twenty-two out of 27 patients underwent 99mTc-MIBI scan within a week of bone marrow sampling. Whole-body images were obtained 10 min after intravenous injection of 555 MBq of the tracer; the extension and intensity of 99mTc-MIBI uptake were graded using the semiquantitative score. A statistically significant correlation was found between in vitro uptake of 99mTc-MIBI and both plasma cell infiltration (Pearson's coefficient of correlation r=0.69, P<0.0001) and in vivo score (Spearman rank correlation coefficient r=0.60, P<0.01). No specific tracer uptake was found in bone marrow samples obtained from the two healthy donors. Micro-autoradiography showed localization of 99mTc-MIBI inside the plasma cells infiltrating the bone marrow. Therefore, our findings show that the degree of tracer uptake both in vitro and in vivo is related to the percentage of infiltrating plasma cells which accumulate the tracer in their inner compartments.

  11. Exclusive photorelease of signalling lipids at the plasma membrane.

    PubMed

    Nadler, André; Yushchenko, Dmytro A; Müller, Rainer; Stein, Frank; Feng, Suihan; Mulle, Christophe; Carta, Mario; Schultz, Carsten

    2015-12-21

    Photoactivation of caged biomolecules has become a powerful approach to study cellular signalling events. Here we report a method for anchoring and uncaging biomolecules exclusively at the outer leaflet of the plasma membrane by employing a photocleavable, sulfonated coumarin derivative. The novel caging group allows quantifying the reaction progress and efficiency of uncaging reactions in a live-cell microscopy setup, thereby greatly improving the control of uncaging experiments. We synthesized arachidonic acid derivatives bearing the new negatively charged or a neutral, membrane-permeant coumarin caging group to locally induce signalling either at the plasma membrane or on internal membranes in β-cells and brain slices derived from C57B1/6 mice. Uncaging at the plasma membrane triggers a strong enhancement of calcium oscillations in β-cells and a pronounced potentiation of synaptic transmission while uncaging inside cells blocks calcium oscillations in β-cells and causes a more transient effect on neuronal transmission, respectively. The precise subcellular site of arachidonic acid release is therefore crucial for signalling outcome in two independent systems.

  12. Data Analysis of the Floating Potential Measurement Unit aboard the International Space Station

    NASA Technical Reports Server (NTRS)

    Barjatya, Aroh; Swenson, Charles M.; Thompson, Donald C.; Wright, Kenneth H., Jr.

    2009-01-01

    We present data from the Floating Potential Measurement Unit (FPMU), that is deployed on the starboard (S1) truss of the International Space Station. The FPMU is a suite of instruments capable of redundant measurements of various plasma parameters. The instrument suite consists of: a Floating Potential Probe, a Wide-sweeping spherical Langmuir probe, a Narrow-sweeping cylindrical Langmuir Probe, and a Plasma Impedance Probe. This paper gives a brief overview of the instrumentation and the received data quality, and then presents the algorithm used to reduce I-V curves to plasma parameters. Several hours of data is presented from August 5th, 2006 and March 3rd, 2007. The FPMU derived plasma density and temperatures are compared with the International Reference Ionosphere (IRI) and USU-Global Assimilation of Ionospheric Measurement (USU-GAIM) models. Our results show that the derived in-situ density matches the USU-GAIM model better than the IRI, and the derived in-situ temperatures are comparable to the average temperatures given by the IRI.

  13. Chemistry Testing on Plasma Versus Serum Samples in Dialysis Patients: Clinical and Quality Improvement Implications.

    PubMed

    Carey, Roger Neill; Jani, Chinu; Johnson, Curtis; Pearce, Jim; Hui-Ng, Patricia; Lacson, Eduardo

    2016-09-07

    Plasma samples collected in tubes containing separator gels have replaced serum samples for most chemistry tests in many hospital and commercial laboratories. Use of plasma samples for blood tests in the dialysis population eliminates delays in sample processing while waiting for clotting to complete, laboratory technical issues associated with fibrin formation, repeat sample collection, and patient care issues caused by delay of results because of incompletely clotted specimens. Additionally, a larger volume of plasma is produced than serum for the same amount of blood collected. Plasma samples are also acceptable for most chemical tests involved in the care of patients with ESRD. This information becomes very important when United States regulatory requirements for ESRD inadvertently limit the type of sample that can be used for government reporting, quality assessment, and value-based payment initiatives. In this narrative, we summarize the renal community experience and how the subsequent resolution of the acceptability of phosphorus levels measured from serum and plasma samples may have significant implications in the country's continued development of a value-based Medicare ESRD Quality Incentive Program. Copyright © 2016 by the American Society of Nephrology.

  14. Synthesis and Characterization of Novel Compound Clusters

    DTIC Science & Technology

    1997-08-26

    also be intrinsically stable, they cannot be formed by this plasma chemistry presumably because the metals are less reactive. Plasma chemistry reactions...samples without the presence of hydrogen. Vaporization of these composite samples produces the metal carbide clusters in many cases where plasma chemistry does...antimony or bismuth cannot be produced by the hydrocarbon plasma chemistry method, but they are produced readily from composite sample (metal film on

  15. Platelet-rich plasma derived growth factors contribute to stem cell differentiation in musculoskeletal regeneration

    NASA Astrophysics Data System (ADS)

    Qian, Yun; Han, Qixin; Chen, Wei; Song, Jialin; Zhao, Xiaotian; Ouyang, Yuanming; Yuan, Weien; Fan, Cunyi

    2017-10-01

    Stem cell treatment and platelet-rich plasma (PRP) therapy are two significant issues in regenerative medicine. Stem cells such as bone marrow mesenchymal stem cells, adipose-derived stem cells and periodontal ligament stem cells can be successfully applied in the field of tissue regeneration. PRP, a natural product isolated from whole blood, can secrete multiple growth factors (GFs) for regulating physiological activities. These GFs can stimulate proliferation and differentiation of different stem cells in injury models. Therefore, combination of both agents receives wide expectations in regenerative medicine, especially in bone, cartilage and tendon repair. In this review, we thoroughly discussed the interaction and underlying mechanisms of platelet-rich plasma derived growth factors with stem cells, and assessed their functions in cell differentiation for musculoskeletal regeneration.

  16. A computer model for the recombination zone of a microwave-plasma electrothermal rocket

    NASA Technical Reports Server (NTRS)

    Filpus, John W.; Hawley, Martin C.

    1987-01-01

    As part of a study of the microwave-plasma electrothermal rocket, a computer model of the flow regime below the plasma has been developed. A second-order model, including axial dispersion of energy and material and boundary conditions at infinite length, was developed to partially reproduce the absence of mass-flow rate dependence that was seen in experimental temperature profiles. To solve the equations of the model, a search technique was developed to find the initial derivatives. On integrating with a trial set of initial derivatives, the values and their derivatives were checked to judge whether the values were likely to attain values outside the practical regime, and hence, the boundary conditions at infinity were likely to be violated. Results are presented and directions for further development are suggested.

  17. Effects of embryo size at transfer (whole versus demi) and early pregnancy progesterone supplementation on embryo growth and pregnancy-specific protein bovine concentrations in recipient dairy heifers.

    PubMed

    Lopes-da-Costa, L; Chagas e Silva, J; Deloche, M C; Jeanguyot, N; Humblot, P; Horta, A E M

    2011-08-01

    The objectives of this study were to evaluate embryonic size and survival, plasma progesterone (P4) and pregnancy-specific protein bovine (PSPB) concentrations in early pregnancies (n = 99) following the transfer of one whole (n = 66) or one demi (n = 33) embryo to recipient virgin dairy heifers. The experiment was designed to evaluate the fixed effects of embryo size at transfer (whole or demi embryo) on Day 7 of the estrous cycle (Day 0 = estrus) and P4 supplementation between Days 7 to 19 through an intravaginal device (yes or no) on plasma P4 and PSPB concentrations and on embryo measurements. Plasma P4 concentrations were measured by RIA on Days 0, 7, 14, 19, 21, 25, 35, 42, 49, 56 and 63 of pregnancy and, PSPB concentrations were measured by ELISA on Days 7, 21, 25, 35, 42, 49, 56 and 63. The presence of an embryonic vesicle was detected on Day 25, embryonic/fetal movements and heartbeat were evaluated on Days 42 and 63 and embryo measurements [crown-rump length (CRL) and width at mid body] were obtained on Day 42 through ultrasonography. In non-supplemented pregnancies, Day 42 whole embryos had higher (P < 0.05) CRL and width than demi embryos, but the difference averaged only 1 to 2 mm. In P4 supplemented pregnancies, whole and demi embryos attained a similar size on Day 42 of pregnancy. Embryo size at transfer, early exogenous P4 supplementation and their interactions had no effects (P > 0.05) on plasma P4 concentrations. However, the post-hoc LSD evaluation showed that plasma P4 concentrations on Day 25 were higher (P < 0.001) in whole than in demi embryo derived pregnancies and, that exogenous P4 supplementation increased (P < 0.05) plasma P4 concentrations on Day 19 of pregnancy. The plasma PSPB detection rate on Days 7 to 63 of pregnancy was similar in pregnancies resulting from the transfer of whole and demi embryos. From a total of 93 recipients remaining pregnant until Day 63, plasma PSPB was constantly undetectable on Day 7, was detected in 4% of Day 21 samples, 41% of Day 25, 95% of Day 35, 96% of Day 42, 99% of Day 49 and in 100% of samples of Days 56 and 63. Concentrations of PSPB increased (P < 0.05) from Days 21 to 42 and from Days 56 to 63, with a plateau between Days 42 to 56. Demi embryo pregnancies had higher (P < 0.05) plasma PSPB concentrations on Days 35 and 42 than whole embryo pregnancies. Progesterone supplementation had a positive effect (P < 0.01) on PSPB concentrations from Days 35 to 63. Concentrations of PSPB were similar in non-supplemented whole and demi embryo pregnancies from Days 7 to Day 63. In contrast, in supplemented recipients, demi embryo pregnancies had higher (P < 0.05) PSPB concentrations on Days 25 to 42 than whole embryo pregnancies. No significant correlation was found between P4 and PSPB concentrations or between the concentrations of these hormones and embryonic measurements on Day 42. In conclusion, demi embryos experienced a compensatory growth until Day 42 of pregnancy, attaining a similar size to that of whole embryos and originating conceptuses producing similar plasma PSPB concentrations to those of whole embryo derived conceptuses. Embryonic growth and conceptus secretion of PSPB were positively stimulated by early pregnancy exogenous P4 treatment. Copyright © 2011 Elsevier Inc. All rights reserved.

  18. Novel Parvovirus and Related Variant in Human Plasma

    PubMed Central

    Fryer, Jacqueline F.; Kapoor, Amit; Minor, Philip D.; Delwart, Eric

    2006-01-01

    We report a novel parvovirus (PARV4) and related variants in pooled human plasma used in the manufacture of plasma-derived medical products. Viral DNA was detected by using highly selective polymerase chain reaction assays; 5% of pools tested positive, and amounts of DNA ranged from <500 copies/mL to >106 copies/mL plasma. PMID:16494735

  19. Non-invasive prenatal diagnosis.

    PubMed

    Meaney, Cathy; Norbury, Gail

    2011-01-01

    The discovery of cell-free fetal DNA in the maternal plasma of pregnant women has facilitated the development of non-invasive prenatal diagnosis (NIPD). This has been successfully implemented in diagnostic laboratories for Rhesus typing and fetal sex determination for X-linked disorders and congenital adrenal hyperplasia (CAH) from 7 weeks gestation. Using real-time PCR, fluorescently labelled target gene specific probes can identify and quantify low copy number fetal-specific sequences in a high background of maternal DNA in the cell-free DNA extracted from maternal plasma.NIPD to detect specific fetal mutations in single gene disorders, currently by standard PCR techniques, can only be undertaken for paternally derived or de novo mutations because of the background maternal DNA. For routine use, this testing is limited by the large amounts of cell-free maternal DNA in the sample, the lack of universal fetal markers, and appropriate reference materials.

  20. Effects of loading modes on densification efficiency of spark plasma sintering: sample study of zirconium carbide consolidation

    NASA Astrophysics Data System (ADS)

    Wei, Xialu; Maximenko, Andrey L.; Back, Christina; Izhvanov, Oleg; Olevsky, Eugene A.

    2017-07-01

    Theoretical studies on the densification kinetics of the new spark plasma sinter-forging (SPS-forging) consolidation technique and of the regular SPS have been carried out based on the continuum theory of sintering. Both modelling and verifying experimental results indicate that the loading modes play important roles in the densification efficiency of SPS of porous ZrC specimens. Compared to regular SPS, SPS-forging is shown to be able to enhance the densification more significantly during later sintering stages. The derived analytical constitutive equations are utilised to evaluate the high-temperature creep parameters of ZrC under SPS conditions. SPS-forging and regular SPS setups are combined to form a new SPS hybrid loading mode with the purpose of reducing shape irregularity in the SPS-forged specimens. Loading control is imposed to secure the geometry as well as the densification of ZrC specimens during hybrid SPS process.

  1. A validated method for the quantification of fosfomycin on dried plasma spots by HPLC-MS/MS: application to a pilot pharmacokinetic study in humans.

    PubMed

    Parker, Suzanne L; Lipman, Jeffrey; Dimopoulos, George; Roberts, Jason A; Wallis, Steven C

    2015-11-10

    Quantification of fosfomycin in the plasma samples of patients is the basis of clinical pharmacokinetic studies from which evidence based dosing regimens can be devised to maximise antibiotic effectiveness against a pathogen. We have developed and validated a LC-MS/MS method to quantify fosfomycin using dried plasma spot sampling. Following HILIC chromatography, fosfomycin and ethylphosphonic acid, used as internal standard, were measured using negative-ion multiple reaction monitoring. The method was linear over the calibration range of 5-2000mg/L of fosfomycin. Intra-day assay results for dried plasma spot quality control samples at 15.6, 79.9 and 1581mg/L of fosfomycin had precision of ±4.2, 8.2, and 2.0%, respectively, and accuracy of +3.9, -0.1, and -1.2%, respectively. Recovery of fosfomycin from dried plasma spots was calculated as 83.6% and the dried plasma spot samples were found to be stable stored at room temperature for three months and when stored for four hours at 50°C. A Bland-Altman plot comparing DPS to plasma sampling found a negative bias of 16.6%, with all but one sample within the mean limits of agreement (-2.6 to 30.6%). Dried plasma spot sampling provides a useful tool for pharmacokinetic research of fosfomycin. Copyright © 2015 Elsevier B.V. All rights reserved.

  2. Plasma Modes

    NASA Astrophysics Data System (ADS)

    Dubin, D. H. E.

    This chapter explores several aspects of the linear electrostatic normal modes of oscillation for a single-species non-neutral plasma in a Penning trap. Linearized fluid equations of motion are developed, assuming the plasma is cold but collisionless, which allow derivation of the cold plasma dielectric tensor and the electrostatic wave equation. Upper hybrid and magnetized plasma waves in an infinite uniform plasma are described. The effect of the plasma surface in a bounded plasma system is considered, and the properties of surface plasma waves are characterized. The normal modes of a cylindrical plasma column are discussed, and finally, modes of spheroidal plasmas, and finite temperature effects on the modes, are briefly described.

  3. Stable and unstable roots of ion temperature gradient driven mode using curvature modified plasma dispersion functions

    NASA Astrophysics Data System (ADS)

    Gültekin, Ö.; Gürcan, Ö. D.

    2018-02-01

    Basic, local kinetic theory of ion temperature gradient driven (ITG) mode, with adiabatic electrons is reconsidered. Standard unstable, purely oscillating as well as damped solutions of the local dispersion relation are obtained using a bracketing technique that uses the argument principle. This method requires computing the plasma dielectric function and its derivatives, which are implemented here using modified plasma dispersion functions with curvature and their derivatives, and allows bracketing/following the zeros of the plasma dielectric function which corresponds to different roots of the ITG dispersion relation. We provide an open source implementation of the derivatives of modified plasma dispersion functions with curvature, which are used in this formulation. Studying the local ITG dispersion, we find that near the threshold of instability the unstable branch is rather asymmetric with oscillating solutions towards lower wave numbers (i.e. drift waves), and damped solutions toward higher wave numbers. This suggests a process akin to inverse cascade by coupling to the oscillating branch towards lower wave numbers may play a role in the nonlinear evolution of the ITG, near the instability threshold. Also, using the algorithm, the linear wave diffusion is estimated for the marginally stable ITG mode.

  4. Comparison of serum, EDTA plasma and P100 plasma for luminex-based biomarker multiplex assays in patients with chronic obstructive pulmonary disease in the SPIROMICS study.

    PubMed

    O'Neal, Wanda K; Anderson, Wayne; Basta, Patricia V; Carretta, Elizabeth E; Doerschuk, Claire M; Barr, R Graham; Bleecker, Eugene R; Christenson, Stephanie A; Curtis, Jeffrey L; Han, Meilan K; Hansel, Nadia N; Kanner, Richard E; Kleerup, Eric C; Martinez, Fernando J; Miller, Bruce E; Peters, Stephen P; Rennard, Stephen I; Scholand, Mary Beth; Tal-Singer, Ruth; Woodruff, Prescott G; Couper, David J; Davis, Sonia M

    2014-01-08

    As a part of the longitudinal Chronic Obstructive Pulmonary Disease (COPD) study, Subpopulations and Intermediate Outcome Measures in COPD study (SPIROMICS), blood samples are being collected from 3200 subjects with the goal of identifying blood biomarkers for sub-phenotyping patients and predicting disease progression. To determine the most reliable sample type for measuring specific blood analytes in the cohort, a pilot study was performed from a subset of 24 subjects comparing serum, Ethylenediaminetetraacetic acid (EDTA) plasma, and EDTA plasma with proteinase inhibitors (P100). 105 analytes, chosen for potential relevance to COPD, arranged in 12 multiplex and one simplex platform (Myriad-RBM) were evaluated in duplicate from the three sample types from 24 subjects. The reliability coefficient and the coefficient of variation (CV) were calculated. The performance of each analyte and mean analyte levels were evaluated across sample types. 20% of analytes were not consistently detectable in any sample type. Higher reliability and/or smaller CV were determined for 12 analytes in EDTA plasma compared to serum, and for 11 analytes in serum compared to EDTA plasma. While reliability measures were similar for EDTA plasma and P100 plasma for a majority of analytes, CV was modestly increased in P100 plasma for eight analytes. Each analyte within a multiplex produced independent measurement characteristics, complicating selection of sample type for individual multiplexes. There were notable detectability and measurability differences between serum and plasma. Multiplexing may not be ideal if large reliability differences exist across analytes measured within the multiplex, especially if values differ based on sample type. For some analytes, the large CV should be considered during experimental design, and the use of duplicate and/or triplicate samples may be necessary. These results should prove useful for studies evaluating selection of samples for evaluation of potential blood biomarkers.

  5. Comparison of serum, EDTA plasma and P100 plasma for luminex-based biomarker multiplex assays in patients with chronic obstructive pulmonary disease in the SPIROMICS study

    PubMed Central

    2014-01-01

    Background As a part of the longitudinal Chronic Obstructive Pulmonary Disease (COPD) study, Subpopulations and Intermediate Outcome Measures in COPD study (SPIROMICS), blood samples are being collected from 3200 subjects with the goal of identifying blood biomarkers for sub-phenotyping patients and predicting disease progression. To determine the most reliable sample type for measuring specific blood analytes in the cohort, a pilot study was performed from a subset of 24 subjects comparing serum, Ethylenediaminetetraacetic acid (EDTA) plasma, and EDTA plasma with proteinase inhibitors (P100™). Methods 105 analytes, chosen for potential relevance to COPD, arranged in 12 multiplex and one simplex platform (Myriad-RBM) were evaluated in duplicate from the three sample types from 24 subjects. The reliability coefficient and the coefficient of variation (CV) were calculated. The performance of each analyte and mean analyte levels were evaluated across sample types. Results 20% of analytes were not consistently detectable in any sample type. Higher reliability and/or smaller CV were determined for 12 analytes in EDTA plasma compared to serum, and for 11 analytes in serum compared to EDTA plasma. While reliability measures were similar for EDTA plasma and P100 plasma for a majority of analytes, CV was modestly increased in P100 plasma for eight analytes. Each analyte within a multiplex produced independent measurement characteristics, complicating selection of sample type for individual multiplexes. Conclusions There were notable detectability and measurability differences between serum and plasma. Multiplexing may not be ideal if large reliability differences exist across analytes measured within the multiplex, especially if values differ based on sample type. For some analytes, the large CV should be considered during experimental design, and the use of duplicate and/or triplicate samples may be necessary. These results should prove useful for studies evaluating selection of samples for evaluation of potential blood biomarkers. PMID:24397870

  6. Mixed-mode ion exchange-based integrated proteomics technology for fast and deep plasma proteome profiling.

    PubMed

    Xue, Lu; Lin, Lin; Zhou, Wenbin; Chen, Wendong; Tang, Jun; Sun, Xiujie; Huang, Peiwu; Tian, Ruijun

    2018-06-09

    Plasma proteome profiling by LC-MS based proteomics has drawn great attention recently for biomarker discovery from blood liquid biopsy. Due to standard multi-step sample preparation could potentially cause plasma protein degradation and analysis variation, integrated proteomics sample preparation technologies became promising solution towards this end. Here, we developed a fully integrated proteomics sample preparation technology for both fast and deep plasma proteome profiling under its native pH. All the sample preparation steps, including protein digestion and two-dimensional fractionation by both mixed-mode ion exchange and high-pH reversed phase mechanism were integrated into one spintip device for the first time. The mixed-mode ion exchange beads design achieved the sample loading at neutral pH and protein digestion within 30 min. Potential sample loss and protein degradation by pH changing could be voided. 1 μL of plasma sample with depletion of high abundant proteins was processed by the developed technology with 12 equally distributed fractions and analyzed with 12 h of LC-MS gradient time, resulting in the identification of 862 proteins. The combination of the Mixed-mode-SISPROT and data-independent MS method achieved fast plasma proteome profiling in 2 h with high identification overlap and quantification precision for a proof-of-concept study of plasma samples from 5 healthy donors. We expect that the Mixed-mode-SISPROT become a generally applicable sample preparation technology for clinical oriented plasma proteome profiling. Copyright © 2018 Elsevier B.V. All rights reserved.

  7. Thermometry of the system “heat-resistant sample - incident plasma stream”

    NASA Astrophysics Data System (ADS)

    Sargsyan, M. A.; Chinnov, V. F.; Kavyrshin, D. I.; Gadzhiev, M. Kh; Khromov, M. A.; Chistolinov, A. V.; Senchenko, V. N.

    2017-11-01

    To study the interacting system “heat-resistant sample - an incident plasma stream” a setup of synchronized measurement equipment was developed and tested that recorded the main parameters of such interaction. Heat resistance tests were carried out on the samples of MPG-6 grade isotropic graphite, and samples of pyrolytic graphite that were subjected to a long (60 … 100 s) exposure to nitrogen, argon and air plasma streams at atmospheric pressure. As plasma generators a series of plasma torches with a vortex stabilization of the stream and an expanding anode channels was used. The temperature and composition of the plasma in the jet and near the sample were determined using two AvaSpec2048 and AvaSpec3648 scanning optical spectrometers and the MS5402i spectrograph with the Andor matrix at its outlet. The surface temperature of the sample was determined in real time using three independent ways: two pyrometric systems - a high-speed micro-pyrometer FMP1001 and a two-position visualization of the heated sample by high-speed Motion Pro X3 and VS-FAST cameras, and the spectral analysis of the wide-range thermal radiation of the samples. The main method for determining the rate of material loss during the action of a plasma jet on it was to analyze a two-position synchronous visualization of the “jet-sample” system. When a crater was formed on the surface of the sample under the “dagger” effect of a plasma jet, a video recording system of the crater zone was used, backlit using the “laser knife” method.

  8. Identification of HIV-1 genitourinary tract compartmentalization by analyzing the env gene sequences in urine.

    PubMed

    Blasi, Maria; Carpenter, J Harris; Balakumaran, Bala; Cara, Andrea; Gao, Feng; Klotman, Mary E

    2015-08-24

    HIV-1 persists indefinitely in memory CD4 T cells and other long-lived cellular reservoirs despite antiretroviral therapy. Our group had previously demonstrated that HIV-1 can establish a productive infection in renal epithelial cells and that the kidney represents a separate compartment for HIV-1 replication. Here, to better understand the viruses in this unique site, we genetically characterized and compared the viruses in blood and urine specimens from 24 HIV-1 infected patients with detectable viremia. Blood and urine samples were obtained from 35 HIV-1 positive patients. Single-genome amplification was performed on HIV-1 env RNA and DNA isolated from urine supernatants and urine-derived cell pellets, respectively, as well as from plasma and peripheral blood mononuclear cell from the same individuals. Neighbor-joining trees were constructed under the Kimura 2-parameter model. We amplified and sequenced the full-length HIV-1 envelope (env) gene from 12 of the 24 individuals, indicating that 50% of the viremic HIV-1-positive patients had viral RNA in their urine. Phylogenetic analysis of the env sequences from four individuals with more than 15 urine-derived env sequences showed that the majority of the sequences from urine formed distinct cluster(s) independent of those peripheral blood mononuclear cell and plasma-derived sequences, consistent with viral compartmentalization in the urine. Our results suggest the presence of a distinct HIV compartment in the genitourinary tract.

  9. Identification of HIV-1 Genitourinary Tract Compartmentalization by Analyzing the env Gene Sequences in Urine

    PubMed Central

    BLASI, Maria; CARPENTER, J. Harris; BALAKUMARAN, Bala; CARA, Andrea; GAO, Feng; KLOTMAN, Mary E.

    2015-01-01

    Objective HIV-1 persists indefinitely in memory CD4+ T cells and other long-lived cellular reservoirs despite antiretroviral therapy (ART). Our group had previously demonstrated that HIV-1 can establish a productive infection in renal epithelial cells and that the kidney represents a separate compartment for HIV-1 replication. Here, to better understand the viruses in this unique site, we genetically characterized and compared the viruses in blood and urine specimens from twenty-four HIV-1 infected subjects with detectable viremia. Design and Methods Blood and urine samples were obtained from 35 HIV-1 positive subjects. Single-genome amplification was performed on HIV-1 env RNA and DNA isolated from urine supernatants and urine derived cell pellets respectively, as well as from plasma and PBMC from the same individuals. Neighbor-joining trees were constructed under the Kimura 2-parameter mode. Results We amplified and sequenced the full-length HIV-1 envelope (env) gene from twelve of the twenty-four individuals, indicating that fifty percent (50%) of the viremic HIV-1 positive patients had viral RNA in their urine. Phylogenetic analysis of the env sequences from four subjects with more than fifteen urine-derived env sequences showed that the majority of the sequences from urine formed distinct cluster(s) independent of those PBMC and plasma-derived sequences, consistent with viral compartmentalization in the urine. Conclusions Our results suggest the presence of a distinct HIV compartment in the genitourinary tract. PMID:26372275

  10. Branched-chain amino acids as biomarkers in diabetes.

    PubMed

    Giesbertz, Pieter; Daniel, Hannelore

    2016-01-01

    Numerous human studies have consistently demonstrated that concentrations of branched-chain amino acids (BCAAs) in plasma and urine are associated with insulin resistance and have the quality to predict diabetes development. However, it is not known how altered BCAA levels link to insulin action and diabetes. This review addresses some recent findings in BCAA metabolism and discusses their role as reporter molecules of insulin sensitivity and diabetes and their possible contribution to disease progression. Changes in plasma and urine levels result mainly from altered metabolism in tissues and recent studies have thus focused on organ-specific changes in BCAA handling using animal models and human tissue samples. A decreased mitochondrial oxidation has been demonstrated in peripheral tissues and that was shown to be associated with an increased inflammatory tone and changes in adipokine levels (adiponectin and leptin). These changes appear already before insulin resistance is established. Key findings demonstrating the discordance between changes in BCAA and insulin resistance are derived from studies using insulin sensitizers and from data collected in patients undergoing Roux-en-Y bypass bariatric surgery. Intermediates derived from BCAA breakdown rather than BCAA itself were recently proposed to contribute to the development of insulin resistance and studies now explore the biomarker qualities of these metabolites. Understanding the mechanisms and putative causalities in the alterations in BCAA levels as found in obesity, metabolic syndrome and diabetes is crucial for any intervention options but also for the use of BCAA and derivatives as biomarkers in clinical routine.

  11. Early cognitive impairment along with decreased stress-induced BDNF in male and female patients with newly diagnosed multiple sclerosis.

    PubMed

    Prokopova, Barbora; Hlavacova, Natasa; Vlcek, Miroslav; Penesova, Adela; Grunnerova, Lucia; Garafova, Alexandra; Turcani, Peter; Kollar, Branislav; Jezova, Daniela

    2017-01-15

    The aim of this study was to evaluate neuroendocrine activation during stress in patients with recently diagnosed multiple sclerosis before starting the immunomodulatory therapy (EDSS score≤2.0). We verified the hypothesis that certain cognitive and affective dysfunction is present already at this early stage of the disease. The sample consisted of 38 subjects, which involved patients who were recently diagnosed multiple sclerosis and age- and sex-matched healthy volunteers. Stroop test served as mental stress model enabling measurement of cognitive performance. Present results showed increased state anxiety, depression scores and poorer performance in the Stroop test in the group of patients compared to healthy subjects. The cognitive dysfunction was particularly evident in male patients with simultaneously decreased concentrations of the brain-derived neurotrophic factor (BDNF) in plasma. The patients at this stage of the disease have not yet developed the hyperactivity of the hypothalamic-pituitary-adrenocortical axis. They showed normal levels of plasma copeptin and reduced aldosterone response to mental stress test in women only. Concentrations of plasma copeptin were higher in men compared to women. Very early stages of multiple sclerosis are accompanied by disturbances in psychological well-being, mild cognitive dysfunction and decreased plasma concentrations of BDNF, particularly in male patients. Copyright © 2016. Published by Elsevier B.V.

  12. Theory of Thomson scattering in inhomogeneous plasmas

    NASA Astrophysics Data System (ADS)

    Belyi, V. V.

    2018-05-01

    A self-consistent kinetic theory of Thomson scattering of an electromagnetic field by a nonuniform plasma is derived. We show that not only the imaginary part, but also the time and space derivatives of the real part of the dielectric susceptibility determine the amplitude and the width of the Thomson scattering spectral lines. As a result of inhomogeneity, these properties become asymmetric with respect to inversion of the sign of the frequency. Our theory provides a method of a remote probing and measurement of electron density gradients in plasma; this is based on the demonstrated asymmetry of the Thomson scattering lines.

  13. Acceleration of Ions and Electrons by Wave-Particle Interactions

    DTIC Science & Technology

    1984-03-31

    of cyclotron radiation from high-temperature plasmas including collective effects have been derived and discussed in two recent articles by Freund...however, will be presented in separate articles . In summary, the spontaneous cyclotron emissivity has been calcu- lated using the complete...diation from high-temperature plasmas including collective effects are derived and discussed in two recent articles by Freund and Wu’ and Audenaerde

  14. Swarm Utilisation Analysis: LEO satellite observations for the ESA's SSA Space Weather network

    NASA Astrophysics Data System (ADS)

    Kervalishvili, Guram; Stolle, Claudia; Rauberg, Jan; Olsen, Nils; Vennerstrøm, Susanne; Gullikstad Johnsen, Magnar; Hall, Chris

    2017-04-01

    ESA's (European Space Agency) constellation mission Swarm was successfully launched on 22 November 2013. The three satellites achieved their final constellation on 17 April 2014 and since then Swarm-A and Swarm-C orbiting the Earth at about 470 km (flying side-by-side) and Swarm-B at about 520 km altitude. Each of Swarm satellite carries instruments with high precision to measure magnetic and electric fields, neutral and plasma densities, and TEC (Total Electron Content) for which a dual frequency GPS receiver is used. SUA (Swarm Utilisation Analysis) is a project of the ESA's SSA (Space Situational Awareness) SWE (Space Weather) program. Within this framework GFZ (German Research Centre for Geosciences, Potsdam, Germany) and DTU (National Space Institute, Kongens Lyngby, Denmark) have developed two new Swarm products ROT (Rate Of change of TEC) and PEJ (Location and intensity level of Polar Electrojets), respectively. ROT is derived as the first time derivative from the Swarm measurements of TEC at 1 Hz sampling. ROT is highly relevant for users in navigation and communications: strong plasma gradients cause GPS signal degradation or even loss of GPS signal. Also, ROT is a relevant space weather asset irrespective of geomagnetic activity, e.g., high amplitude values of ROT occur during all geomagnetic conditions. PEJ is derived from the Swarm measurements of the magnetic field strength at 1 Hz sampling. PEJ has a high-level importance for power grid companies since the polar electrojet is a major cause for ground-induced currents. ROT and PEJ together with five existing Swarm products TEC, electron density, IBI (Ionospheric Bubble Index), FAC (Field-Aligned Current), and vector magnetic field build the SUA service prototype. This prototype will be integrated into ESA's SSA Space Weather network as a federated service and will be available soon from ESA's SSA SWE Ionospheric Weather and Geomagnetic Conditions Expert Service Centres (ESCs).

  15. Salient features of solitary waves in dusty plasma under the influence of Coriolis force

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Das, G. C.; Nag, Apratim; Department of Physics, G. C. College, Silchar-788004

    The main interest is to study the nonlinear acoustic wave in rotating dusty plasma augmented through the derivation of a modified Sagdeev potential equation. Small rotation causes the interaction of Coriolis force in the dynamical system, and leads to the complexity in the derivation of the nonlinear wave equation. As a result, the finding of solitary wave propagation in dusty plasma ought to be of merit. However, the nonlinear wave equation has been successfully solved by the use of the hyperbolic method. Main emphasis has been given to the changes on the evolution and propagation of soliton, and the variationmore » caused by the dusty plasma constituents as well as by the Coriolis force have been highlighted. Some interesting nonlinear wave behavior has been found which can be elaborately studied for the interest of laboratory and space plasmas. Further, to support the theoretical investigations, numeric plasma parameters have been taken for finding the inherent features of solitons.« less

  16. A macroscopic plasma Lagrangian and its application to wave interactions and resonances

    NASA Technical Reports Server (NTRS)

    Peng, Y. K. M.

    1974-01-01

    The derivation of a macroscopic plasma Lagrangian is considered, along with its application to the description of nonlinear three-wave interaction in a homogeneous plasma and linear resonance oscillations in a inhomogeneous plasma. One approach to obtain the Lagrangian is via the inverse problem of the calculus of variations for arbitrary first and second order quasilinear partial differential systems. Necessary and sufficient conditions for the given equations to be Euler-Lagrange equations of a Lagrangian are obtained. These conditions are then used to determine the transformations that convert some classes of non-Euler-Lagrange equations to Euler-Lagrange equation form. The Lagrangians for a linear resistive transmission line and a linear warm collisional plasma are derived as examples. Using energy considerations, the correct macroscopic plasma Lagrangian is shown to differ from the velocity-integrated low Lagrangian by a macroscopic potential energy that equals twice the particle thermal kinetic energy plus the energy lost by heat conduction.

  17. Co-gasification of bituminous coal and hydrochar derived from municipal solid waste: Reactivity and synergy.

    PubMed

    Wei, Juntao; Guo, Qinghua; He, Qing; Ding, Lu; Yoshikawa, Kunio; Yu, Guangsuo

    2017-09-01

    In this work, the influences of gasification temperature and blended ratio on co-gasification reactivity and synergy of Shenfu bituminous coal (SF) and municipal solid waste-derived hydrochar (HTC) were investigated using TGA. Additionally, active alkaline and alkaline earth metal (AAEM) transformation during co-gasification was quantitatively analyzed by inductively coupled plasma optical emission spectrometer for correlating synergy on co-gasification reactivity. The results showed that higher char gasification reactivity existed at higher HTC char proportion and gasification temperature, and the main synergy behaviour on co-gasification reactivity was performed as synergistic effect. Enhanced synergistic effect at lower temperature was mainly resulted from more obviously inhibiting the primary AAEM (i.e. active Ca) transformation, and weak synergistic effect still existed at higher temperature since more active K with prominent catalysis was retained. Furthermore, more active HTC-derived AAEM remaining in SF sample during co-gasification would lead to enhanced synergistic effect as HTC char proportion increased. Copyright © 2017 Elsevier Ltd. All rights reserved.

  18. Paritaprevir and Ritonavir Liver Concentrations in Rats as Assessed by Different Liver Sampling Techniques

    PubMed Central

    Venuto, Charles S.; Markatou, Marianthi; Woolwine-Cunningham, Yvonne; Furlage, Rosemary; Ocque, Andrew J.; DiFrancesco, Robin; Dumas, Emily O.; Wallace, Paul K.; Morse, Gene D.

    2017-01-01

    ABSTRACT The liver is crucial to pharmacology, yet substantial knowledge gaps exist in the understanding of its basic pharmacologic processes. An improved understanding for humans requires reliable and reproducible liver sampling methods. We compared liver concentrations of paritaprevir and ritonavir in rats by using samples collected by fine-needle aspiration (FNA), core needle biopsy (CNB), and surgical resection. Thirteen Sprague-Dawley rats were evaluated, nine of which received paritaprevir/ritonavir at 30/20 mg/kg of body weight by oral gavage daily for 4 or 5 days. Drug concentrations were measured using liquid chromatography-tandem mass spectrometry on samples collected via FNA (21G needle) with 1, 3, or 5 passes (FNA1, FNA3, and FNA5); via CNB (16G needle); and via surgical resection. Drug concentrations in plasma were also assessed. Analyses included noncompartmental pharmacokinetic analysis and use of Bland-Altman techniques. All liver tissue samples had higher paritaprevir and ritonavir concentrations than those in plasma. Resected samples, considered the benchmark measure, resulted in estimations of the highest values for the pharmacokinetic parameters of exposure (maximum concentration of drug in serum [Cmax] and area under the concentration-time curve from 0 to 24 h [AUC0–24]) for paritaprevir and ritonavir. Bland-Altman analyses showed that the best agreement occurred between tissue resection and CNB, with 15% bias, followed by FNA3 and FNA5, with 18% bias, and FNA1 and FNA3, with a 22% bias for paritaprevir. Paritaprevir and ritonavir are highly concentrated in rat liver. Further research is needed to validate FNA sampling for humans, with the possible derivation and application of correction factors for drug concentration measurements. PMID:28264852

  19. Paritaprevir and Ritonavir Liver Concentrations in Rats as Assessed by Different Liver Sampling Techniques.

    PubMed

    Venuto, Charles S; Markatou, Marianthi; Woolwine-Cunningham, Yvonne; Furlage, Rosemary; Ocque, Andrew J; DiFrancesco, Robin; Dumas, Emily O; Wallace, Paul K; Morse, Gene D; Talal, Andrew H

    2017-05-01

    The liver is crucial to pharmacology, yet substantial knowledge gaps exist in the understanding of its basic pharmacologic processes. An improved understanding for humans requires reliable and reproducible liver sampling methods. We compared liver concentrations of paritaprevir and ritonavir in rats by using samples collected by fine-needle aspiration (FNA), core needle biopsy (CNB), and surgical resection. Thirteen Sprague-Dawley rats were evaluated, nine of which received paritaprevir/ritonavir at 30/20 mg/kg of body weight by oral gavage daily for 4 or 5 days. Drug concentrations were measured using liquid chromatography-tandem mass spectrometry on samples collected via FNA (21G needle) with 1, 3, or 5 passes (FNA 1 , FNA 3 , and FNA 5 ); via CNB (16G needle); and via surgical resection. Drug concentrations in plasma were also assessed. Analyses included noncompartmental pharmacokinetic analysis and use of Bland-Altman techniques. All liver tissue samples had higher paritaprevir and ritonavir concentrations than those in plasma. Resected samples, considered the benchmark measure, resulted in estimations of the highest values for the pharmacokinetic parameters of exposure (maximum concentration of drug in serum [ C max ] and area under the concentration-time curve from 0 to 24 h [AUC 0-24 ]) for paritaprevir and ritonavir. Bland-Altman analyses showed that the best agreement occurred between tissue resection and CNB, with 15% bias, followed by FNA 3 and FNA 5 , with 18% bias, and FNA 1 and FNA 3 , with a 22% bias for paritaprevir. Paritaprevir and ritonavir are highly concentrated in rat liver. Further research is needed to validate FNA sampling for humans, with the possible derivation and application of correction factors for drug concentration measurements. Copyright © 2017 American Society for Microbiology.

  20. Electron density and electron temperature measurement in a bi-Maxwellian electron distribution using a derivative method of Langmuir probes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Choi, Ikjin; Chung, ChinWook; Youn Moon, Se

    2013-08-15

    In plasma diagnostics with a single Langmuir probe, the electron temperature T{sub e} is usually obtained from the slope of the logarithm of the electron current or from the electron energy probability functions of current (I)-voltage (V) curve. Recently, Chen [F. F. Chen, Phys. Plasmas 8, 3029 (2001)] suggested a derivative analysis method to obtain T{sub e} by the ratio between the probe current and the derivative of the probe current at a plasma potential where the ion current becomes zero. Based on this method, electron temperatures and electron densities were measured and compared with those from the electron energymore » distribution function (EEDF) measurement in Maxwellian and bi-Maxwellian electron distribution conditions. In a bi-Maxwellian electron distribution, we found the electron temperature T{sub e} obtained from the method is always lower than the effective temperatures T{sub eff} derived from EEDFs. The theoretical analysis for this is presented.« less

  1. High-performance liquid chromatographic determination of the beta2-selective adrenergic agonist fenoterol in human plasma after fluorescence derivatization.

    PubMed

    Kramer, S; Blaschke, G

    2001-02-10

    A sensitive high-performance liquid chromatographic method has been developed for the determination of the beta2-selective adrenergic agonist fenoterol in human plasma. To improve the sensitivity of the method, fenoterol was derivatized with N-(chloroformyl)-carbazole prior to HPLC analysis yielding highly fluorescent derivatives. The assay involves protein precipitation with acetonitrile, liquid-liquid-extraction of fenoterol from plasma with isobutanol under alkaline conditions followed by derivatization with N-(chloroformyl)-carbazole. Reversed-phase liquid chromatographic determination of the fenoterol derivative was performed using a column-switching system consisting of a LiChrospher 100 RP 18 and a LiChrospher RP-Select B column with acetonitrile, methanol and water as mobile phase. The limit of quantitation in human plasma was 376 pg fenoterol/ml. The method was successfully applied for the assay of fenoterol in patient plasma.

  2. Angular distributions of plasma edge velocity and integrated intensity: Update on specific impulse for Ablative Laser Propulsion

    NASA Astrophysics Data System (ADS)

    Lin, Jun; Pakhomov, Andrew V.

    2005-04-01

    This work concludes our discussion of the image processing technique developed earlier for determination of specific impulse (Isp) for Ablative Laser Propulsion (ALP). The plasma plumes are recorded with a time-resolved intensified charge-coupled device (ICCD) camera. The plasma was formed in vacuum (˜ 3×10-3 Torr) by focusing output pulses of a laser system (100-ps pulsewidth at 532 nm wavelength and ˜35 mJ energy) on surfaces of C (graphite), Al, Si, Fe, Cu, Zn, Sn, and Pb elements. Angular profiles for integrated intensity and plasma expansion velocity were determined for the tested elements. Such profiles were used further for assessment of specific impulse. Specific impulses derived from angular distributions of plasma expansion velocity and integral intensity appeared in excellent agreement with the data derived earlier from force measurements.

  3. Nuclear Fusion Within Extremely Dense Plasma Enhanced by Quantum Particle Waves

    NASA Astrophysics Data System (ADS)

    Miao, Feng; Zheng, Xianjun; Deng, Baiquan

    2015-05-01

    Quantum effects play an enhancement role in p-p chain reactions occurring within stars. Such an enhancement is quantified by a wave penetration factor that is proportional to the density of the participating fuel particles. This leads to an innovative theory for dense plasma, and its result shows good agreement with independent data derived from the solar energy output. An analysis of the first Z-pinch machine in mankind's history exhibiting neutron emission leads to a derived deuterium plasma beam density greater than that of water, with plasma velocities exceeding 10000 km/s. Fusion power could be achieved by the intersection of four such pinched plasma beams with powerful head-on collisions in their common focal region due to the beam and target enhanced reaction. supported by the Fund for the Construction of Graduate Degree of China (No. 2014XWD-S0805)

  4. Two dimensional radial gas flows in atmospheric pressure plasma-enhanced chemical vapor deposition

    NASA Astrophysics Data System (ADS)

    Kim, Gwihyun; Park, Seran; Shin, Hyunsu; Song, Seungho; Oh, Hoon-Jung; Ko, Dae Hong; Choi, Jung-Il; Baik, Seung Jae

    2017-12-01

    Atmospheric pressure (AP) operation of plasma-enhanced chemical vapor deposition (PECVD) is one of promising concepts for high quality and low cost processing. Atmospheric plasma discharge requires narrow gap configuration, which causes an inherent feature of AP PECVD. Two dimensional radial gas flows in AP PECVD induces radial variation of mass-transport and that of substrate temperature. The opposite trend of these variations would be the key consideration in the development of uniform deposition process. Another inherent feature of AP PECVD is confined plasma discharge, from which volume power density concept is derived as a key parameter for the control of deposition rate. We investigated deposition rate as a function of volume power density, gas flux, source gas partial pressure, hydrogen partial pressure, plasma source frequency, and substrate temperature; and derived a design guideline of deposition tool and process development in terms of deposition rate and uniformity.

  5. Plasma density limits for hole boring by intense laser pulses.

    PubMed

    Iwata, Natsumi; Kojima, Sadaoki; Sentoku, Yasuhiko; Hata, Masayasu; Mima, Kunioki

    2018-02-12

    High-power lasers in the relativistic intensity regime with multi-picosecond pulse durations are available in many laboratories around the world. Laser pulses at these intensities reach giga-bar level radiation pressures, which can push the plasma critical surface where laser light is reflected. This process is referred to as the laser hole boring (HB), which is critical for plasma heating, hence essential for laser-based applications. Here we derive the limit density for HB, which is the maximum plasma density the laser can reach, as a function of laser intensity. The time scale for when the laser pulse reaches the limit density is also derived. These theories are confirmed by a series of particle-in-cell simulations. After reaching the limit density, the plasma starts to blowout back toward the laser, and is accompanied by copious superthermal electrons; therefore, the electron energy can be determined by varying the laser pulse length.

  6. 21 CFR 26.4 - Product coverage.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... subpart. (b) Human blood, human plasma, human tissues and organs, and veterinary immunologicals (under 9... the scope of this subpart. Human plasma derivatives (such as immunoglobulins and albumin...

  7. 21 CFR 26.4 - Product coverage.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... subpart. (b) Human blood, human plasma, human tissues and organs, and veterinary immunologicals (under 9... the scope of this subpart. Human plasma derivatives (such as immunoglobulins and albumin...

  8. Random and independent sampling of endogenous tryptic peptides from normal human EDTA plasma by liquid chromatography micro electrospray ionization and tandem mass spectrometry.

    PubMed

    Dufresne, Jaimie; Florentinus-Mefailoski, Angelique; Ajambo, Juliet; Ferwa, Ammara; Bowden, Peter; Marshall, John

    2017-01-01

    Normal human EDTA plasma samples were collected on ice, processed ice cold, and stored in a freezer at - 80 °C prior to experiments. Plasma test samples from the - 80 °C freezer were thawed on ice or intentionally warmed to room temperature. Protein content was measured by CBBR binding and the release of alcohol soluble amines by the Cd ninhydrin assay. Plasma peptides released over time were collected over C18 for random and independent sampling by liquid chromatography micro electrospray ionization and tandem mass spectrometry (LC-ESI-MS/MS) and correlated with X!TANDEM. Fully tryptic peptides by X!TANDEM returned a similar set of proteins, but was more computationally efficient, than "no enzyme" correlations. Plasma samples maintained on ice, or ice with a cocktail of protease inhibitors, showed lower background amounts of plasma peptides compared to samples incubated at room temperature. Regression analysis indicated that warming plasma to room temperature, versus ice cold, resulted in a ~ twofold increase in the frequency of peptide identification over hours-days of incubation at room temperature. The type I error rate of the protein identification from the X!TANDEM algorithm combined was estimated to be low compared to a null model of computer generated random MS/MS spectra. The peptides of human plasma were identified and quantified with low error rates by random and independent sampling that revealed 1000s of peptides from hundreds of human plasma proteins from endogenous tryptic peptides.

  9. BDNF Val66Met polymorphism and plasma levels in Chinese Han population with obsessive-compulsive disorder and generalized anxiety disorder.

    PubMed

    Wang, Yuan; Zhang, Haiyin; Li, Ying; Wang, Zhen; Fan, Qing; Yu, Shunying; Lin, Zhiguang; Xiao, Zeping

    2015-11-01

    Anxiety disorders are a category of mental disorders characterized by feelings of anxiety and fear, which include generalized anxiety disorder (GAD). Obsessive-Compulsive Disorder (OCD) used to be categorized as anxiety disorder in DSM-IV. However OCD was no longer included in anxiety disorders and came into its own category titled as Obsessive-Compulsive and Related Disorders (OCRD) in DSM-5. It will be interesting to explore is there any different biological characteristics between OCD and anxiety disorders. Brain-derived neurotrophic factor (BDNF) was a potential candidate gene in both OCD and GAD. The results of genetic association studies between BDNF and OCD have been inconsistent. BDNF plasma/serum levels in OCD have been found lower than those in healthy controls. However the heritable reason of the lowered BDNF levels was not well elucidated. The amount of studies about BDNF and GAD were relatively small. The aims of this study were to determine whether single nucleotide polymorphism Val66Met of BDNF was associated with OCD and GAD, to examine BDNF plasma levels in OCD and GAD, and to explore whether Val66Met variation influences BDNF plasma levels. We genotyped Val66Met variation in 148 OCD patients, 108 GAD patients and 99 healthy controls. Within the same sample, BDNF plasma levels were determined in 113 OCD patients, 102 GAD patients and 63 healthy controls. Val66Met variation was not associated with OCD or GAD. BDNF plasma levels in OCD and GAD patients were significant lower than those in healthy controls. Val66Met variation had no influence on BDNF plasma levels. No difference was found between OCD and GAD. Results do not change no matter taking OCD and GAD as one group or separated two. First, the sample size for genotyping was relatively small, which leaded to a low statistical power of the genetic part in this study. Second, we genotyped just one SNP in BDNF gene. Third, parts of the participants did not be assayed for BDNF plasma levels. Our findings support the hypothesis that BDNF is involved in the pathophysiology of mental disorders, not only OCD but also GAD. OCD and GAD patients both show lower BDNF plasma levels compared to healthy controls. The BDNF plasma levels are not associated with Val66Met variation. Copyright © 2015 Elsevier B.V. All rights reserved.

  10. Long-term effectiveness of plasma-derived hepatitis B vaccine 22-28 years after immunization in a hepatitis B virus endemic rural area: is an adult booster dose needed?

    PubMed

    Li, H; Li, G J; Chen, Q Y; Fang, Z L; Wang, X Y; Tan, C; Yang, Q L; Wang, F Z; Wang, F; Zhang, S; Bi, S L; Shen, L P

    2017-04-01

    Longan County is considered a highly endemic area for hepatitis B virus (HBV). The plasma-derived vaccine has been used in newborns in this area since 1987. A cross-sectional survey was conducted to evaluate the long-term effectiveness of this vaccine. In total, 1634 participants born during 1987-1993 and who had received a series of plasma-derived HB vaccinations at ages 0, 1, and 6 months were enrolled. Serological HBV markers were detected and compared with previous survey data. Overall the prevalence of hepatitis B surface antigen (HBsAg) in all participants was 3·79%; 3·47% of subjects who had received the first dose within 24 h were HBsAg positive, and 8·41% of subjects who had received a delayed first dose were also HBsAg positive. There were 1527 subjects identified who had received the first dose within 24 h and whose HBsAg and anti-HBc prevalence increased yearly after immunization, while the anti-HBs-positive rate and vaccine effectiveness declined. The geometric mean concentration of antibody in the anti-HB-positive participants was 55·13 mIU/ml and this declined after immunization. Fewer than 2·0% of participants had anti-HB levels ⩾1000 mIU/ml. The data show that the protective efficacy of the plasma-derived vaccinations declined and administration of HB vaccine within 24 h of birth was very important. To reduce the risk of HBV infection in this highly endemic area, a booster dose might be necessary if anti-HBs levels fall below 10 mIU/ml after age 18 years. Furthermore, studies on the immune memory induced by plasma-derived HB vaccine are needed.

  11. Expanded Stem Cells, Stromal-Vascular Fraction, and Platelet-Rich Plasma Enriched Fat: Comparing Results of Different Facial Rejuvenation Approaches in a Clinical Trial

    PubMed Central

    Rigotti, Gino; Charles-de-Sá, Luiz; Gontijo-de-Amorim, Natale Ferreira; Takiya, Christina Maeda; Amable, Paola Romina; Borojevic, Radovan; Benati, Donatella; Bernardi, Paolo; Sbarbati, Andrea

    2016-01-01

    Background In a previous study, the authors demonstrated that treatment with expanded adipose-derived stem cells or stromal vascular fraction (SVF)-enriched fat modify the pattern of the dermis in human beings, representing a skin rejuvenation effect. Considering that expanded stem cells require a cell factor, the authors wanted to assess similar results by replacing them with platelet-rich plasma (PRP), which is easier to obtain and for which an empirical regenerative effect has been already described. Objectives To determine if PRP injection could replace the cutaneous regenerative effect of adipose-derived stem cells. Methods This study was performed in 13 patients who were candidates for facelift. The patients underwent sampling of fat by liposuction from the abdomen and submitted to one of three protocols: injection of SVF-enriched fat or expanded adipose-derived stem cells or fat plus PRP in the preauricular areas. Fragments of skin were removed before and 3 months after treatment and analyzed by optical and electron microscopy. Results The use of fat plus PRP led to the presence of more pronounced inflammatory infiltrates and a greater vascular reactivity, increasing in vascular permeability and a certain reactivity of the nervous component. The addition of PRP did not improve the regenerative effect. Conclusion The use of PRP did not have significant advantages in skin rejuvenation over the use of expanded adipose-derived stem cells or SVF-enriched fat. The effect of increased vascular reactivity may be useful in pathological situations in which an intense angiogenesis is desirable, such as tissular ischemia. Level of Evidence: 4 Therapeutic PMID:26879294

  12. Strongly magnetized classical plasma models

    NASA Technical Reports Server (NTRS)

    Montgomery, D. C.

    1972-01-01

    The class of plasma processes for which the so-called Vlasov approximation is inadequate is investigated. Results from the equilibrium statistical mechanics of two-dimensional plasmas are derived. These results are independent of the presence of an external dc magnetic field. The nonequilibrium statistical mechanics of the electrostatic guiding-center plasma, a two-dimensional plasma model, is discussed. This model is then generalized to three dimensions. The guiding-center model is relaxed to include finite Larmor radius effects for a two-dimensional plasma.

  13. A liquid chromatography/tandem mass spectrometry assay for the analysis of atomoxetine in human plasma and in vitro cellular samples

    PubMed Central

    Appel, David I.; Brinda, Bryan; Markowitz, John S.; Newcorn, Jeffrey H.; Zhu, Hao-Jie

    2012-01-01

    A simple, rapid and sensitive method for quantification of atomoxetine by liquid chromatography- tandem mass spectrometry (LC-MS/MS) was developed. This assay represents the first LC-MS/MS quantification method for atomoxetine utilizing electrospray ionization. Deuterated atomoxetine (d3-atomoxetine) was adopted as the internal standard. Direct protein precipitation was utilized for sample preparation. This method was validated for both human plasma and in vitro cellular samples. The lower limit of quantification was 3 ng/ml and 10 nM for human plasma and cellular samples, respectively. The calibration curves were linear within the ranges of 3 ng/ml to 900 ng/ml and 10 nM to 10 μM for human plasma and cellular samples, respectively (r2 > 0.999). The intra- and inter-day assay accuracy and precision were evaluated using quality control samples at 3 different concentrations in both human plasma and cellular lysate. Sample run stability, assay selectivity, matrix effect, and recovery were also successfully demonstrated. The present assay is superior to previously published LC-MS and LC-MS/MS methods in terms of sensitivity or the simplicity of sample preparation. This assay is applicable to the analysis of atomoxetine in both human plasma and in vitro cellular samples. PMID:22275222

  14. Evaluation of optimized bronchoalveolar lavage sampling designs for characterization of pulmonary drug distribution.

    PubMed

    Clewe, Oskar; Karlsson, Mats O; Simonsson, Ulrika S H

    2015-12-01

    Bronchoalveolar lavage (BAL) is a pulmonary sampling technique for characterization of drug concentrations in epithelial lining fluid and alveolar cells. Two hypothetical drugs with different pulmonary distribution rates (fast and slow) were considered. An optimized BAL sampling design was generated assuming no previous information regarding the pulmonary distribution (rate and extent) and with a maximum of two samples per subject. Simulations were performed to evaluate the impact of the number of samples per subject (1 or 2) and the sample size on the relative bias and relative root mean square error of the parameter estimates (rate and extent of pulmonary distribution). The optimized BAL sampling design depends on a characterized plasma concentration time profile, a population plasma pharmacokinetic model, the limit of quantification (LOQ) of the BAL method and involves only two BAL sample time points, one early and one late. The early sample should be taken as early as possible, where concentrations in the BAL fluid ≥ LOQ. The second sample should be taken at a time point in the declining part of the plasma curve, where the plasma concentration is equivalent to the plasma concentration in the early sample. Using a previously described general pulmonary distribution model linked to a plasma population pharmacokinetic model, simulated data using the final BAL sampling design enabled characterization of both the rate and extent of pulmonary distribution. The optimized BAL sampling design enables characterization of both the rate and extent of the pulmonary distribution for both fast and slowly equilibrating drugs.

  15. Small RNA profiling of low biomass samples: identification and removal of contaminants.

    PubMed

    Heintz-Buschart, Anna; Yusuf, Dilmurat; Kaysen, Anne; Etheridge, Alton; Fritz, Joëlle V; May, Patrick; de Beaufort, Carine; Upadhyaya, Bimal B; Ghosal, Anubrata; Galas, David J; Wilmes, Paul

    2018-05-14

    Sequencing-based analyses of low-biomass samples are known to be prone to misinterpretation due to the potential presence of contaminating molecules derived from laboratory reagents and environments. DNA contamination has been previously reported, yet contamination with RNA is usually considered to be very unlikely due to its inherent instability. Small RNAs (sRNAs) identified in tissues and bodily fluids, such as blood plasma, have implications for physiology and pathology, and therefore the potential to act as disease biomarkers. Thus, the possibility for RNA contaminants demands careful evaluation. Herein, we report on the presence of small RNA (sRNA) contaminants in widely used microRNA extraction kits and propose an approach for their depletion. We sequenced sRNAs extracted from human plasma samples and detected important levels of non-human (exogenous) sequences whose source could be traced to the microRNA extraction columns through a careful qPCR-based analysis of several laboratory reagents. Furthermore, we also detected the presence of artefactual sequences related to these contaminants in a range of published datasets, thereby arguing in particular for a re-evaluation of reports suggesting the presence of exogenous RNAs of microbial and dietary origin in blood plasma. To avoid artefacts in future experiments, we also devise several protocols for the removal of contaminant RNAs, define minimal amounts of starting material for artefact-free analyses, and confirm the reduction of contaminant levels for identification of bona fide sequences using 'ultra-clean' extraction kits. This is the first report on the presence of RNA molecules as contaminants in RNA extraction kits. The described protocols should be applied in the future to avoid confounding sRNA studies.

  16. Determination of 18 beta-glycyrrhetinic acid in biological fluids from humans and rats by solid-phase extraction and high-performance liquid chromatography.

    PubMed

    Hasler, F; Krapf, R; Brenneisen, R; Bourquin, D; Krähenbühl, S

    1993-10-22

    Methods have been developed and characterized allowing rapid isolation and quantification of 18 beta-glycyrrhetinic acid (GRA) in biological fluids from both humans and rats. Sample preparation includes extraction with urea-methanol for plasma samples, and solid-phase extraction (SPE) for urine and bile samples. Hydrolysis of GRA glucuronides in urine and bile was performed by treatment with beta-glucuronidase. MGRA, the 3-O-methyl derivative of GRA was synthesized as an internal standard resistant to hydrolysis. High-performance liquid chromatography (HPLC) was performed with an isocratic system using methanol-water-acetic acid (83:16.8:0.2, v/v/v) as solvent on a Lichrocart RP-18 column at 30 degrees C with ultraviolet detection. The methods allowed base line separation of GRA and MGRA from all biological fluids tested, with a detection limit of 0.15 mg/l. Validation of the methods included determination of recovery, accuracy and precision in plasma, bile and urine from humans and rats. The methods were further evaluated by investigating the pharmacokinetics of GRA in normal rats and in rats with a bile fistula. Following an intravenous dose of 10 mg/kg, the plasma concentration-time curve of GRA could be fitted to a one compartment model both in control and bile fistula rats. The elimination half life averaged 15.0 +/- 2.2 versus 16.8 +/- 2.4 min in control and bile fistula rats (difference not significant). Within 90 min following administration of GRA, urinary elimination of GRA and GRA glucuronides was less than 1% in both groups whereas biliary elimination averaged 51.3 +/- 3.1%. The results show that the methods developed allow pharmacokinetic studies of GRA in humans and rats.

  17. Ion-pressure equations derived from measurements in space.

    PubMed

    Stasiewicz, K

    2005-07-01

    Cluster measurements at the bow shock, the magnetosheath, and the magnetospheric boundary layer are used to derive ion-pressure equations for hot anisotropic plasmas. It is demonstrated that both perpendicular and parallel ion pressures are well approximated by polybaric expressions is proportional to N(gamma)B(kappa), where N is the plasma density, B is the magnetic field, gamma is in the range 0.5 to 2, and kappa is between -2 and 0. The parameters derived from observations are distinctively different from those predicted by double-adiabatic theory and are shown to hold for pressure variations over 4 orders of magnitude and for a range of plasma beta (ratio of kinetic/magnetic pressures) between 10(-4) and 10. The results are relevant for simulations and theories of astrophysical, solar, interplanetary, and magnetospheric processes based on MHD equations.

  18. Adiabatic bulk modulus of elasticity for 2D liquid dusty plasmas

    NASA Astrophysics Data System (ADS)

    Feng, Yan; Huang, Dong; Li, Wei

    2018-05-01

    From the recently obtained equation of state (EOS) for two-dimensional (2D) liquid dusty plasmas, their various physical quantities have been derived analytically, such as the specific heat CV, the Grüneisen parameter, the bulk modulus of elasticity, and the isothermal compressibility. Here, the coefficient of volumetric thermal expansion αV and the relative pressure coefficient αP of 2D liquid dusty plasmas are derived from their EOS. Using the obtained CV, αV, and αP, the analytical expression of their heat capacity under constant-pressure conditions CP is obtained. Thus, the heat capacity ratio, expressed as CP/CV , is analytically achieved. Then the adiabatic bulk modulus of elasticity is derived, so that the adiabatic sound speeds are obtained. These obtained results are compared with previous findings using a different approach.

  19. Plasma-derived exosomes contribute to inflammation via the TLR9-NF-κB pathway in chronic heart failure patients.

    PubMed

    Ye, Wei; Tang, Xiaojun; Yang, Zhengquan; Liu, Chu; Zhang, Xin; Jin, Jing; Lyu, Jianxin

    2017-07-01

    Exosomes are small vesicles that contain proteins, DNA and RNA, and play an important role in inflammation; however, the underlying mechanism remains unclear. In the present study, we found increased plasma-derived exosomes in chronic heart failure patients compared with healthy controls. Further, our data demonstrated that plasma-derived exosomes carried mtDNA, and triggered an inflammatory response via the TLR9-NF-κB pathway, as well, the inflammatory effect was closely related to exosomal mtDNA copy number. However, the effect could be blocked by chloroquine (CQ), a TLR9 inhibitor. These findings reveal a new mechanism of exosome-induced inflammation, and provide a new perspective for intervention and treatment of inflammation-related diseases, such as chronic heart failure. Copyright © 2017 Elsevier Ltd. All rights reserved.

  20. Measurement of Clozapine, Norclozapine, and Amisulpride in Plasma and in Oral Fluid Obtained Using 2 Different Sampling Systems.

    PubMed

    Fisher, Danielle S; Beyer, Chad; van Schalkwyk, Gerrit; Seedat, Soraya; Flanagan, Robert J

    2017-04-01

    There is a poor correlation between total concentrations of proton-accepting compounds (most basic drugs) in unstimulated oral fluid and in plasma. The aim of this study was to compare clozapine, norclozapine, and amisulpride concentrations in plasma and in oral fluid collected using commercially available collection devices [Thermo Fisher Scientific Oral-Eze and Greiner Bio-One (GBO)]. Oral-Eze and GBO samples and plasma were collected in that order from patients prescribed clozapine. Analyte concentrations were measured by liquid chromatography-tandem mass spectrometry. There were 112 participants [96 men, aged (median, range) 47 (21-65) years and 16 women, aged 44 (21-65) years]: 74 participants provided 2 sets of samples and 7 provided 3 sets (overall 2 GBO samples not collected). Twenty-three patients were co-prescribed amisulpride, of whom 17 provided 2 sets of samples and 1 provided 3 sets. The median (range) oral fluid within the GBO samples was 52 (13%-86%). Nonadherence to clozapine was identified in all 3 samples in one instance. After correction for oral fluid content, analyte concentrations in the GBO and Oral-Eze samples were poorly correlated with plasma clozapine and norclozapine (R = 0.57-0.63) and plasma amisulpride (R = 0.65-0.72). Analyte concentrations in the 2 sets of oral fluid samples were likewise poorly correlated (R = 0.68-0.84). Mean (SD) plasma clozapine and norclozapine were 0.60 (0.46) and 0.25 (0.21) mg/L, respectively. Mean clozapine and norclozapine concentrations in the 2 sets of oral fluid samples were similar to those in plasma (0.9-1.8 times higher), that is, approximately 2- to 3-fold higher than those in unstimulated oral fluid. The mean (±SD) amisulpride concentrations (microgram per liter) in plasma (446 ± 297) and in the Oral-Eze samples (501 ± 461) were comparable and much higher than those in the GBO samples (233 ± 318). Oral fluid collected using either the GBO system or the Oral-Eze system cannot be used for quantitative clozapine and/or amisulpride therapeutic drug monitoring.

  1. Recombinant DNA derived monomeric insulin analogue: comparison with soluble human insulin in normal subjects.

    PubMed

    Vora, J P; Owens, D R; Dolben, J; Atiea, J A; Dean, J D; Kang, S; Burch, A; Brange, J

    1988-11-12

    To compare the rate of absorption from subcutaneous tissue and the resulting hypoglycaemic effect of iodine-125 labelled soluble human insulin and a monomeric insulin analogue derived by recombinant DNA technology. Single blind randomised comparison of equimolar doses of 125I labelled soluble human insulin and insulin analogue. Study in normal people at a diabetes research unit and a university department of medical physics. Seven healthy male volunteers aged 20-39 not receiving any other drugs. After an overnight fast and a basal period of one hour two doses (0.05 and 0.1 U/kg) of 125I labelled soluble human insulin and insulin analogue were injected subcutaneously into the anterior abdominal wall on four separate days. To find a fast acting insulin for meal related requirements in insulin dependent diabetics. MEASUREMENTS and main results--Residual radioactivity at the injection site was measured continuously for the first two hours after injection of the 125I labelled preparations and thereafter for five minutes simultaneously with blood sampling. Frequent venous blood samples were obtained over six hours for determination of plasma immunoreactive insulin, insulin analogue, glucose, and glucagon values. Time to 50% of initial radioactivity at the injection site for the insulin analogue compared with soluble insulin was 61 v 135 minutes (p less than 0.05) with 0.05 U/kg and 67 v 145 minutes (p less than 0.001) with 0.1 U/kg. Concentrations in plasma increased faster after the insulin analogue compared with soluble insulin, resulting in higher plasma concentrations between 10 and 150 minutes (0.001 less than p less than 0.05) after 0.05 U/kg and between 40 and 360 minutes (0.001 less than p less than 0.05) after 0.1 U/kg. The hypoglycaemic response to insulin analogue was a plasma glucose nadir at 60 minutes with both doses compared with 90 and 120 minutes with soluble insulin at 0.5 and 0.1 U/kg respectively. The response of glucagon substantiated the earlier and more dramatic hypoglycaemic effect with the insulin analogue. The much faster absorption from subcutaneous tissue of the disubstituted monomeric insulin analogue compared with soluble insulin suggests that the analogue may be a potential candidate for rapid insulin delivery after subcutaneous bolus injection.

  2. Recombinant DNA derived monomeric insulin analogue: comparison with soluble human insulin in normal subjects.

    PubMed Central

    Vora, J. P.; Owens, D. R.; Dolben, J.; Atiea, J. A.; Dean, J. D.; Kang, S.; Burch, A.; Brange, J.

    1988-01-01

    OBJECTIVE--To compare the rate of absorption from subcutaneous tissue and the resulting hypoglycaemic effect of iodine-125 labelled soluble human insulin and a monomeric insulin analogue derived by recombinant DNA technology. DESIGN--Single blind randomised comparison of equimolar doses of 125I labelled soluble human insulin and insulin analogue. SETTING--Study in normal people at a diabetes research unit and a university department of medical physics. SUBJECTS--Seven healthy male volunteers aged 20-39 not receiving any other drugs. INTERVENTIONS--After an overnight fast and a basal period of one hour two doses (0.05 and 0.1 U/kg) of 125I labelled soluble human insulin and insulin analogue were injected subcutaneously into the anterior abdominal wall on four separate days. END POINT--To find a fast acting insulin for meal related requirements in insulin dependent diabetics. MEASUREMENTS and main results--Residual radioactivity at the injection site was measured continuously for the first two hours after injection of the 125I labelled preparations and thereafter for five minutes simultaneously with blood sampling. Frequent venous blood samples were obtained over six hours for determination of plasma immunoreactive insulin, insulin analogue, glucose, and glucagon values. Time to 50% of initial radioactivity at the injection site for the insulin analogue compared with soluble insulin was 61 v 135 minutes (p less than 0.05) with 0.05 U/kg and 67 v 145 minutes (p less than 0.001) with 0.1 U/kg. Concentrations in plasma increased faster after the insulin analogue compared with soluble insulin, resulting in higher plasma concentrations between 10 and 150 minutes (0.001 less than p less than 0.05) after 0.05 U/kg and between 40 and 360 minutes (0.001 less than p less than 0.05) after 0.1 U/kg. The hypoglycaemic response to insulin analogue was a plasma glucose nadir at 60 minutes with both doses compared with 90 and 120 minutes with soluble insulin at 0.5 and 0.1 U/kg respectively. The response of glucagon substantiated the earlier and more dramatic hypoglycaemic effect with the insulin analogue. CONCLUSIONS--The much faster absorption from subcutaneous tissue of the disubstituted monomeric insulin analogue compared with soluble insulin suggests that the analogue may be a potential candidate for rapid insulin delivery after subcutaneous bolus injection. PMID:3145064

  3. Maternal serum pregnancy-associated plasma protein A and fetal nuchal translucency thickness for the prediction of fetal trisomies in early pregnancy.

    PubMed

    Brizot, M L; Snijders, R J; Bersinger, N A; Kuhn, P; Nicolaides, K H

    1994-12-01

    To determine if the risk for fetal trisomies during the first trimester of pregnancy can be derived by combining data from maternal serum pregnancy-associated plasma protein A (PAPP-A) and fetal nuchal translucency thickness. Pregnancy-associated plasma protein A was measured in samples from 87 singleton pregnancies with fetal chromosomal abnormalities (45 trisomy 21, 19 trisomy 18, eight trisomy 13, 11 sex chromosome aneuploidies, four triploidies) and 348 chromosomally normal controls at 10-13 weeks' gestation. Likelihood ratios for trisomies 21, 18, and 13 in relation to PAPP-A, in multiples of the normal median (MoM) for crown-rump length, were derived from the overlapping gaussian frequency distribution curves for normal and abnormal pregnancies. In the chromosomally normal group, maternal serum PAPP-A correlated significantly with fetal crown-rump length (r = 0.421, P < .0001). In the chromosomally abnormal group, the median PAPP-A was significantly lower than in the normal controls. The respective median values expressed in MoM for trisomies 21, 18, and 13 and other aneuploidies were 0.5 MoM (90% confidence interval [CI] 0.09-1.67, z = 6.0, P < .001), 0.17 MoM (90% CI 0.06-1.45, z = 6.6, P < .001), 0.25 MoM (90% CI 0.10-0.62, z = 4.5, P < .001), and 0.72 MoM (90% CI 0.09-2.48, z = 2.2, P < .05), respectively. There was no significant linear association between PAPP-A and fetal nuchal translucency thickness in either the chromosomally normal (r = -0.01, P = .89) or abnormal groups (r = -0.19, P = .08). The risks for fetal trisomies at 10-13 weeks' gestation can be derived by combining data on maternal age, maternal serum PAPP-A, and fetal nuchal translucency thickness.

  4. Freezer anthropology: new uses for old blood.

    PubMed Central

    Merriwether, D A

    1999-01-01

    Archived blood fractions (plasma, settled red cells, white cells) have proved to be a rich and valuable source of DNA for human genetic studies. Large numbers of such samples were collected between 1960 and the present for protein and blood group studies, many of which are languishing in freezers or have already been discarded. More are discarded each year because the usefulness of these samples is not widely understood. Data from DNA derived from 10-35-year-old blood samples have been used to address the peopling of the New World and of the Pacific. Mitochondrial DNA haplotypes from studies using this source DNA support a single wave of migration into the New World (or a single source population for the New World), and that Mongolia was the likely source of the founding population. Data from Melanesia have shown that Polynesians are recent immigrants into the Pacific and did not arise from Melanesia. PMID:10091252

  5. Simultaneous Time-concentration Analysis of Soman and VX Adducts to Butyrylcholinesterase and Albumin by LC-MS-MS.

    PubMed

    Lee, Jin Young; Kim, Changhwan; Lee, Yong Han

    2018-06-01

    A sensitive method for the purification and determination of two protein adducts, organophosphorus (OP)-BChE and OP-albumin adducts, in a single sample using a simultaneous sample preparation method was developed and validated using liquid chromatography-tandem mass spectrometry. First, we isolated O-ethyl S-2-diisopropylaminoethyl methyl phosphonothiolate (VX) and O-pinacolyl methylphosphonofluoridate (soman, GD)-BChE adducts using an immunomagnetic separation (IMS) method and the HiTrap™ Blue affinity column was subsequently used to isolate and purify VX and GD-albumin adducts from the plasma of rhesus monkeys exposed to nerve agents. Additionally, we examined the time-concentration profiles of two biomarkers, VX and GD-nonapeptides and VX and GD-tyrosines, derived from OP-BChE and OP-albumin adducts up to 8 weeks after exposure. Based on the results, we determined that VX and GD-tyrosine is more suitable than VX and GD-nonapeptide as a biomarker owing to its longevity. This integrated approach is expected to be applicable for the quantification of other OP-BChE and OP-albumin adducts in human plasma, thus serving as a potential generic assay for exposure to nerve agents.

  6. Impact of Delayed Whole Blood Processing Time on Plasma Levels of miR-1 and miR-423-5p up to 24 Hours.

    PubMed

    Borges, Danielle Pazzotti; Cunha-Neto, Edecio; Bocchi, Edimar A; Rigaud, Vagner Oliveira Carvalho

    2018-03-21

    Circulating cell-free miRNAs hold great promise as a new class of biomarkers due to their high stability in body fluids and association with disease stages. However, even using sensitive and specific methods, technical challenges are associated with miRNA analysis in body fluids. A major source of variation in plasma and serum is the potential cell-derived miRNA contamination from hemolysis. To evaluate the effect of the delayed whole blood processing time on the concentrations of miR-1 and -423-5p. Ten blood samples were incubated for 0, 3 and 24 hours at room temperature prior processing into plasma. For each time point, hemolysis was assessed in plasma by UV spectrophotometry at 414nm wavelength (λ414). Circulating levels of miR-1 and -423-5p were measured by RT-qPCR; miR-23a and -451 were also analyzed as controls. A significant hemolysis was observed only after 24h (λ414 0.3±0.02, p<0.001). However, only small changes in miR-1 and -423-5p levels were observed up to 24h of storage at room temperature (Ct 31.5±0.5 to 31.8±0.6for miR-1, p=0.989; and 29.01±0.3 to 29.04±0.3, p=0.614 for -423-5p). No correlation was observed between hemolysis and levels of miR-1 and -423-5p. Our data indicate the storage of whole blood samples at room temperature for up to 24h prior their processing into plasma does not appear to have a significant impact on miR-1 and -423-5p concentrations. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  7. A Study of Saturn's E-Ring Particles Using the Voyager 1 Plasma Wave Instrument

    NASA Technical Reports Server (NTRS)

    Tsintikidis, D.; Kurth, W. S.; Gurnett, D. A.; Barbosa, D. D.

    1993-01-01

    The flyby of Voyager 1 at Saturn resulted in the detection of a large variety of plasma waves, e.g., chorus, hiss, and electron cyclotron harmonics. Just before the outbound equator crossing, at about 6.1 R(sub s), the Voyager 1 plasma wave instrument detected a strong, well-defined low-frequency enhancement. Initially it was suggested that plasma waves might be responsible for the spectral feature but more recently dust was suggested as at least a partial contributor to the enhancement. In this report we present evidence which supports the conclusion that dust contributes to the low-frequency enhancement. A new method has been used to derive the dust impact rate. The method relies mainly on the 16-channel spectrum analyzer data. The few wide band waveform observations available (which have been used to study dust impacts during the Voyager 2 ring plane crossing) were useful for calibrating the impact rate from the spectrum analyzer data. The mass and, hence, the size of the dust particles were also obtained by analyzing the response of the plasma wave spectrum analyzer. The results show that the region sampled by Voyager 1 is populated by dust particles that have rms masses of up to few times 10(exp -11) g and sizes of up to a few microns. The dust particle number density is on the order of 10(exp -3) m(exp 3). The optical depth of the region sampled by the spacecraft is 1.04 x 10(exp -6). The particle population is centered about 2500 km south of the equatorial plane and has a north-south thickness of about 4000 km. Possible sources of these particles are the moons Enceladus and Tethys whose orbits lie within the E-ring radial extent. These results are in reasonable agreement with photometric studies and numerical simulations.

  8. A blood-based screening tool for Alzheimer's disease that spans serum and plasma: findings from TARC and ADNI.

    PubMed

    O'Bryant, Sid E; Xiao, Guanghua; Barber, Robert; Huebinger, Ryan; Wilhelmsen, Kirk; Edwards, Melissa; Graff-Radford, Neill; Doody, Rachelle; Diaz-Arrastia, Ramon

    2011-01-01

    There is no rapid and cost effective tool that can be implemented as a front-line screening tool for Alzheimer's disease (AD) at the population level. To generate and cross-validate a blood-based screener for AD that yields acceptable accuracy across both serum and plasma. Analysis of serum biomarker proteins were conducted on 197 Alzheimer's disease (AD) participants and 199 control participants from the Texas Alzheimer's Research Consortium (TARC) with further analysis conducted on plasma proteins from 112 AD and 52 control participants from the Alzheimer's Disease Neuroimaging Initiative (ADNI). The full algorithm was derived from a biomarker risk score, clinical lab (glucose, triglycerides, total cholesterol, homocysteine), and demographic (age, gender, education, APOE*E4 status) data. Alzheimer's disease. 11 proteins met our criteria and were utilized for the biomarker risk score. The random forest (RF) biomarker risk score from the TARC serum samples (training set) yielded adequate accuracy in the ADNI plasma sample (training set) (AUC = 0.70, sensitivity (SN) = 0.54 and specificity (SP) = 0.78), which was below that obtained from ADNI cerebral spinal fluid (CSF) analyses (t-tau/Aβ ratio AUC = 0.92). However, the full algorithm yielded excellent accuracy (AUC = 0.88, SN = 0.75, and SP = 0.91). The likelihood ratio of having AD based on a positive test finding (LR+) = 7.03 (SE = 1.17; 95% CI = 4.49-14.47), the likelihood ratio of not having AD based on the algorithm (LR-) = 3.55 (SE = 1.15; 2.22-5.71), and the odds ratio of AD were calculated in the ADNI cohort (OR) = 28.70 (1.55; 95% CI = 11.86-69.47). It is possible to create a blood-based screening algorithm that works across both serum and plasma that provides a comparable screening accuracy to that obtained from CSF analyses.

  9. Physical therapy intervention (PTI) increases plasma brain-derived neurotrophic factor (BDNF) levels in non-frail and pre-frail elderly women.

    PubMed

    Coelho, F M; Pereira, D S; Lustosa, L P; Silva, J P; Dias, J M D; Dias, R C D; Queiroz, B Z; Teixeira, A L; Teixeira, M M; Pereira, L S M

    2012-01-01

    Biomarkers are important factors in the identification of the frail elderly (higher risk of developing disease) and in assessing the impact of PTI. On the other hand, BDNF has been related to neuroprotection in a series of central nervous system diseases in older age. The levels of BDNF in groups of elderly women classified according to Fried phenotype (non-frail and pre-frail) were compared. We assessed the impact of a PTI on BDNF levels. A convenience sample of 48 elderly women was randomly selected. The PTI group was composed by 20 elderly women selected from this group. Plasma neurotrophic factors, such as BDNF, glial-derived neutrophic factor (GDNF), and nerve growth factor (NGF) were measured by enzyme-linked immunosorbent assay (ELISA). Timed-up-and-go (TUG) test, hand-grip and work/body weight were evaluated before and after the intervention. Plasma concentrations of BDNF were significantly higher in non-frail in comparison to pre-frail elderly women. After the PTI, higher levels of BDNF were found in elderly women (before 351±68 pg/ml and after 593±79 pg/ml; p<0.001). Both groups had an increase in BDNF levels after the PTI. The low levels of BDNF in pre-frail elderly women suggest that this neurotrophic factor may be a key pathophysiological mediator in the syndrome of frailty. The fact that PTI increased BDNF levels in both groups suggests that it may be possible to modify this phenotype. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  10. Experimental breakdown of selected anodized aluminum samples in dilute plasmas

    NASA Technical Reports Server (NTRS)

    Grier, Norman T.; Domitz, Stanley

    1992-01-01

    Anodized aluminum samples representative of Space Station Freedom structural material were tested for electrical breakdown under space plasma conditions. In space, this potential arises across the insulating anodized coating when the spacecraft structure is driven to a negative bias relative to the external plasma potential due to plasma-surface interaction phenomena. For anodized materials used in the tests, it was found that breakdown voltage varied from 100 to 2000 volts depending on the sample. The current in the arcs depended on the sample, the capacitor, and the voltage. The level of the arc currents varied from 60 to 1000 amperes. The plasma number density varied from 3 x 10 exp 6 to 10 exp 3 ions per cc. The time between arcs increased as the number density was lowered. Corona testing of anodized samples revealed that samples with higher corona inception voltage had higher arcing inception voltages. From this it is concluded that corona testing may provide a method of screening the samples.

  11. Salivary levels of phosphorus and urea as indices of their plasma levels in nephropathic patients.

    PubMed

    Bilancio, Giancarlo; Cavallo, Pierpaolo; Lombardi, Cinzia; Guarino, Ermanno; Cozza, Vincenzo; Giordano, Francesco; Palladino, Giuseppe; Cirillo, Massimo

    2018-03-30

    Phosphorus and urea are measurable in saliva. Measurements of saliva phosphorus (S-Pho) and saliva urea (S-Urea) could be useful because of low invasivity. Data are limited to saliva tests methodology and to correlations between plasma and saliva compositions. S-Pho and S-Urea were investigated focusing on blind duplicates, differences between collection sites, differences between collection times, freezing-thawing effects, and plasma-saliva correlations. Tests were performed using fresh saliva collected by synthetic swap early morning after overnight fast (standard). Methodology was investigated in fifteen healthy volunteers. Plasma-saliva correlations were investigated in thirty nephropathic outpatients. S-Pho and S-Urea in all measurements ranged above detection limits (0.3 mmol/L). In healthy volunteers, S-Pho and S-Urea were similar in duplicates (results for S-Pho and S-Urea: % difference between samples ≤ 4.85%; R between samples ≥ .976, P < .001), in samples from different mouth sites (≤4.24%; R ≥ .887, P < .001), and in samples of different days (≤5.61%; R ≥ .606, P < .01) but, compared to standard, were substantially lower in after-breakfast samples (-28.0% and -21.3%; R ≥ .786, P < .001) and slightly lower in frozen-thawed samples (-12.4% and -5.92%; R ≥ .742, P < .001). In nephropathic patients, S-Pho was higher than but correlated with plasma phosphorus (saliva/plasma ratio 4.80; R = .686, P < .001), whereas S-Urea and plasma urea were similar and correlated with each other (saliva/plasma ratio 0.96; R = .944, P < .001). Post-dialysis changes in S-Pho and S-Urea paralleled post-dialysis changes in plasma phosphorus and urea. S-Pho and S-Urea reflect plasma phosphorus and plasma urea. Early morning fasting fresh samples are advisable because collection time and freezing-thawing affect saliva tests. © 2018 Wiley Periodicals, Inc.

  12. Plasma surface cleaning using microwave plasmas

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tsai, C.C.; Haselton, H.H.; Nelson, W.D.

    1993-11-01

    In a microwave electron cyclotron resonance (ECR) plasma source, reactive plasmas of oxygen and its mixture with argon are used for plasma-cleaning experiments. Aluminum test samples (0.95 {times} 1.9 cm) were coated with thin films ({le} 20 {mu}m in thickness) of Shell Vitrea oil and cleaned by using such reactive plasmas. The plasma cleaning was done in various discharge conditions with fixed microwave power, rf power, biased potential, gas pressures (0.5 and 5 mtorr), and operating time up to 35 min. The status of plasma cleaning has been monitored by using mass spectroscopy. Mass loss of the samples after plasmamore » cleaning was measured to estimate cleaning rates. Measured clean rates of low pressure (0.5 mtorr) argon/oxygen plasmas were as high as 2.7 {mu}/min. X-ray photoelectron spectroscopy was used to determine cleanliness of the sample surfaces and confirm the effectiveness of plasma cleaning in achieving atomic levels of surface cleanliness. In this paper, significant results are reported and discussed.« less

  13. Evaluation of dried blood spot as an alternative sample collection method for hepatitis C virus RNA quantitation and genotyping using a commercial system.

    PubMed

    Mahajan, Supriya; Choudhary, Manish Chandra; Kumar, Guresh; Gupta, Ekta

    2018-06-01

    Dried blood spot (DBS) is a minimally invasive sampling method suitable for sample collection, storage and transportation in resource limited areas. Aim of this study was to compare the diagnostic utility of DBS with plasma sample for HCV RNA quantitation and genotyping using commercial systems. Plasma and DBS card spotted samples were collected from 95 HCV seropositive patients. Both types of samples were subjected to HCV RNA by real-time PCR (Abbott m2000rt, USA). Genotyping was performed using Abbott HCV genotype II kit (Abbott diagnostics, USA) in samples with viral load > 3 log 10  IU/ml. In both plasma and DBS, 14 (14.7%) samples were negative and 81 (85.3%) were positive for HCV RNA. Median viral load in plasma (3.78; range 0-7.43) log 10  IU/ml was comparable to DBS (3.93; range 0-7.24) log 10  IU/ml. DBS demonstrated sensitivity and specificity of 97.5 and 85.7% respectively, with positive predictive value (PPV) of 97.5% and negative predictive value (NPV) of 85.7%. DBS showed good correlation (r 2  = 0.866) and agreement (93.5%) with plasma. Genotyping in 20 patients showed 100% concordance between DBS and plasma samples. DBS showed good sensitivity and specificity as a sampling method for HCV RNA quantitation and genotyping.

  14. Differential stability of therapeutic peptides with different proteolytic cleavage sites in blood, plasma and serum.

    PubMed

    Böttger, Roland; Hoffmann, Ralf; Knappe, Daniel

    2017-01-01

    Proteolytic degradation of peptide-based drugs is often considered as major weakness limiting systemic therapeutic applications. Therefore, huge efforts are typically devoted to stabilize sequences against proteases present in serum or plasma, obtained as supernatants after complete blood coagulation or centrifugation of blood supplemented with anticoagulants, respectively. Plasma and serum are reproducibly obtained from animals and humans allowing consistent for clinical analyses and research applications. However, the spectrum of active or activated proteases appears to vary depending on the activation of proteases and cofactors during coagulation (serum) or inhibition of such enzymes by anticoagulants (plasma), such as EDTA (metallo- and Ca2+-dependent proteases) and heparin (e.g. thrombin, factor Xa). Here, we studied the presumed effects on peptide degradation by taking blood via cardiac puncture of CD-1 mice using a syringe containing a peptide solution. Due to absence of coagulation activators (e.g. glass surfaces and damaged cells), visible blood clotting was prevented allowing to study peptide degradation for one hour. The remaining peptide was quantified and the degradation products were identified using mass spectrometry. When the degradation rates (half-life times) were compared to serum derived freshly from the same animal and commercial serum and plasma samples, peptides of three different families showed indeed considerably different stabilities. Generally, peptides were faster degraded in serum than in plasma, but surprisingly all peptides were more stable in fresh blood and the order of degradation rates among the peptides varied among the six different incubation experiments. This indicates, that proteolytic degradation of peptide-based therapeutics may often be misleading stimulating efforts to stabilize peptides at degradation sites relevant only in vitro, i.e., for serum or plasma stability assays, but of lower importance in vivo.

  15. Analysis of concentration and (13)C enrichment of D-galactose in human plasma.

    PubMed

    Schadewaldt, P; Hammen, H W; Loganathan, K; Bodner-Leidecker, A; Wendel, U

    2000-05-01

    A stable-isotope dilution method for the sensitive determination of D-galactose in human plasma was established. D-[(13)C]Galactose was added to plasma, and the concentration was measured after D-glucose was removed from the plasma by treatment with D-glucose oxidase and the sample was purified by ion-exchange chromatography. For gas chromatographic-mass spectrometric analysis, aldononitrile pentaacetate derivatives were prepared. Monitoring of the [MH-60](+) ion intensities at m/z 328, 329, and 334 in the positive chemical ionization mode allowed the assessment of 1-(12)C-, 1-(13)C-, and U-(13)C(6)-labeled D-galactose, respectively. The D-galactose concentration was quantified on the basis of the (13)C-labeled internal standard. The method was linear (range examined, 0.1-5 micromol/L) and of good repeatability in the low and high concentration ranges (within- and between-run CVs <15%). The limit of quantification for plasma D-galactose was <0.02 micromol/L. Measurements in plasma of postabsorptive subjects yielded D-galactose concentrations (mean +/- SD) of 0.12 +/- 0.03 (n = 16), 0.11 +/- 0.04 (n = 15), 1.44 +/- 0.54 (n = 10), and 0.17 +/- 0.07 (n = 5) micromol/L in healthy adults, diabetic patients, patients with classical galactosemia, and obligate heterozygous parents thereof, respectively. These data were considerably lower (3- to 18-fold) than the values of a conventional enzymatic assay. The procedure was also applied successfully in a stable-isotope turnover study to evaluate endogenous D-galactose formation. The present findings establish that detection of D-galactose from endogenous sources is feasible in human plasma and show that erroneously high results may be obtained by enzymatic methods.

  16. Fasting Plasma Glucose, Self-Appraised Diet Quality and Depressive Symptoms: A US-Representative Cross-Sectional Study.

    PubMed

    Hoare, Erin; Dash, Sarah R; Varsamis, Pia; Jennings, Garry L; Kingwell, Bronwyn A

    2017-12-07

    Depression and type 2 diabetes (T2D) contribute significantly to global burden of disease and often co-occur. Underpinning type 2 diabetes is poor glycaemic control and glucose is also an obligatory substrate for brain metabolism, with potential implications for cognition, motivation and mood. This research aimed to examine the relationships between fasting plasma glucose and depressive symptoms in a large, population representative sample of US adults, controlling for other demographic and lifestyle behavioural risk factors. Using the 2013-2014 National Health and Nutrition Examination Survey (NHANES) data, this study first investigated the relationship between fasting plasma glucose and mental disorders at a population-level, accounting for demographic, health behavioural and weight-related factors known to co-occur with both type 2 diabetes and mental disorders. Depressive symptoms were derived from the 9-item Patient Health Questionnaire. Fasting plasma glucose was obtained through medical examination and demographic (age, household income, sex) and health characteristics (perceived diet quality, daily time sedentary) were self-reported. Body mass index was calculated from objectively measured height and weight. In the univariate model, higher fasting plasma glucose was associated with greater depressive symptoms among females ( b = 0.24, 95% CI = 0.05, 0.43, p < 0.05), but not males. In the final fully adjusted model, the relationship between fasting plasma glucose and depressive symptoms was non-significant for both males and females. Of all independent variables, self-appraised diet quality was strongly and significantly associated with depressive symptoms and this remained significant when individuals with diabetes were excluded. Although diet quality was self-reported based on individuals' perceptions, these findings are consistent with a role for poor diet in the relationship between fasting plasma glucose and depressive symptoms.

  17. Ion Streaming Instabilities in Pair Ion Plasma and Localized Structure with Non-Thermal Electrons

    NASA Astrophysics Data System (ADS)

    Nasir Khattak, M.; Mushtaq, A.; Qamar, A.

    2015-12-01

    Pair ion plasma with a fraction of non-thermal electrons is considered. We investigate the effects of the streaming motion of ions on linear and nonlinear properties of unmagnetized, collisionless plasma by using the fluid model. A dispersion relation is derived, and the growth rate of streaming instabilities with effect of streaming motion of ions and non-thermal electrons is calculated. A qausi-potential approach is adopted to study the characteristics of ion acoustic solitons. An energy integral equation involving Sagdeev potential is derived during this process. The presence of the streaming term in the energy integral equation affects the structure of the solitary waves significantly along with non-thermal electrons. Possible application of the work to the space and laboratory plasmas are highlighted.

  18. Equalizer technology followed by DIGE-based proteomics for detection of cellular proteins in artificial peritoneal dialysis effluents.

    PubMed

    Lichtenauer, Anton Michael; Herzog, Rebecca; Tarantino, Silvia; Aufricht, Christoph; Kratochwill, Klaus

    2014-05-01

    Peritoneal dialysis effluent (PDE) represents a rich pool of potential biomarkers for monitoring disease and therapy. Until now, proteomic studies have been hindered by the plasma-like composition of the PDE. Beads covered with a peptide library are a promising approach to remove high abundant proteins and concentrate the sample in one step. In this study, a novel approach for proteomic biomarker identification in PDEs consisting of a depletion and concentration step followed by 2D gel based protein quantification was established. To prove this experimental concept a model system of artificial PDEs was established by spiking unused peritoneal dialysis (PD) fluids with cellular proteins reflecting control conditions or cell stress. Using this procedure, we were able to reduce the amount of high abundant plasma proteins and concentrate low abundant proteins while preserving changes in abundance of proteins with cellular origin. The alterations in abundance of the investigated marker for cell stress, the heat shock proteins, showed similar abundance profiles in the artificial PDE as in pure cell culture samples. Our results demonstrate the efficacy of this system in detecting subtle changes in cellular protein expression triggered by unphysiological stress stimuli typical in PD, which could serve as biomarkers. Further studies using patients' PDE will be necessary to prove the concept in clinical PD and to assess whether this technique is also informative regarding enriching low abundant plasma derived protein biomarker in the PDE. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  19. miR-22-5p revealed as a potential biomarker involved in the acute phase of myocardial infarction via profiling of circulating microRNAs.

    PubMed

    Maciejak, Agata; Kiliszek, Marek; Opolski, Grzegorz; Segiet, Agnieszka; Matlak, Krzysztof; Dobrzycki, Slawomir; Tulacz, Dorota; Sygitowicz, Grazyna; Burzynska, Beata; Gora, Monika

    2016-09-01

    Acute myocardial infarction (AMI) is a life-threatening episode of coronary artery disease. Recently, circulating myocardial-derived microRNAs (miRNAs) have been reported as potential biomarkers of infarction. The present study aimed to identify differentially expressed miRNAs in patients with ST-segment elevation myocardial infarction that could be potentially dysregulated in response to early myocardial damage. miRNA expression profile analysis was performed using the Serum/Plasma Focus miRNA Polymerase Chain Reaction (PCR) panel of Exiqon A/S (Vedbaek, Denmark) on plasma samples of patients on the first day of AMI (admission) and on samples from the identical patients collected six months following AMI. Selected miRNAs were validated by reverse transcription‑quantitative PCR (RT‑qPCR) using independent patients with AMI and a control group of patients with a stable coronary artery disease. Thirty‑two species of plasma miRNA were differentially expressed (P<0.05) on admission compared with six months following AMI. Subsequent validation in an independent patient group confirmed that miR‑133b and miR‑22‑5p were significantly up‑regulated in the serum of patients with AMI. The receiver operating characteristic (ROC) curve analysis demonstrated a diagnostic utility for miR-22-5p, which has not previously been reported to be associated with AMI. Among the selected miRNAs, miR‑22‑5p represents a novel promising biomarker for the diagnosis of AMI.

  20. 21 CFR 640.100 - Immune Globulin (Human).

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... (Human). The product is defined as a sterile solution containing antibodies derived from human plasma. (b) Source material. The source material of Immune Globulin (Human) shall be plasma recovered from Whole Blood prepared as prescribed in §§ 640.1 through 640.5, or Source Plasma prepared as prescribed in...

  1. 21 CFR 640.100 - Immune Globulin (Human).

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... (Human). The product is defined as a sterile solution containing antibodies derived from human plasma. (b) Source material. The source material of Immune Globulin (Human) shall be plasma recovered from Whole Blood prepared as prescribed in §§ 640.1 through 640.5, or Source Plasma prepared as prescribed in...

  2. 21 CFR 640.100 - Immune Globulin (Human).

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... (Human). The product is defined as a sterile solution containing antibodies derived from human plasma. (b) Source material. The source material of Immune Globulin (Human) shall be plasma recovered from Whole Blood prepared as prescribed in §§ 640.1 through 640.5, or Source Plasma prepared as prescribed in...

  3. 21 CFR 640.100 - Immune Globulin (Human).

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... (Human). The product is defined as a sterile solution containing antibodies derived from human plasma. (b) Source material. The source material of Immune Globulin (Human) shall be plasma recovered from Whole Blood prepared as prescribed in §§ 640.1 through 640.5, or Source Plasma prepared as prescribed in...

  4. 21 CFR 640.100 - Immune Globulin (Human).

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... (Human). The product is defined as a sterile solution containing antibodies derived from human plasma. (b) Source material. The source material of Immune Globulin (Human) shall be plasma recovered from Whole Blood prepared as prescribed in §§ 640.1 through 640.5, or Source Plasma prepared as prescribed in...

  5. Optical and structural properties of plasma-treated Cordyceps bassiana spores as studied by circular dichroism, absorption, and fluorescence spectroscopy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lee, Geon Joon, E-mail: gjlee@kw.ac.kr; Sim, Geon Bo; Choi, Eun Ha

    To understand the killing mechanism of fungal spores by plasma treatment, the optical, structural, and biological properties of the insect pathogenic fungus Cordyceps bassiana spores were studied. A nonthermal atmospheric-pressure plasma jet (APPJ) was used to treat the spores in aqueous solution. Optical emission spectra of the APPJ acquired in air indicated emission peaks corresponding to hydroxyl radicals and atomic oxygen. When the APPJ entered the aqueous solution, additional reactive species were derived from the interaction of plasma radicals with the aqueous solution. Fluorescence and absorption spectroscopy confirmed the generation of hydroxyl radicals and hydrogen peroxide in the plasma-activated watermore » (PAW). Spore counting showed that plasma treatment significantly reduced spore viability. Absorption spectroscopy, circular dichroism (CD) spectroscopy, and agarose gel electrophoresis of the DNA extracted from plasma-treated spores showed a reduction in spore DNA content. The magnitude of the dip in the CD spectrum was lower in the plasma-treated spores than in the control, indicating that plasma treatment causes structural modifications and/or damage to cellular components. Tryptophan fluorescence intensity was lower in the plasma-treated spores than in the control, suggesting that plasma treatment modified cell wall proteins. Changes in spore viability and DNA content were attributed to structural modification of the cell wall by reactive species coming from the APPJ and the PAW. Our results provided evidence that the plasma radicals and the derived reactive species play critical roles in fungal spore inactivation.« less

  6. Optical and structural properties of plasma-treated Cordyceps bassiana spores as studied by circular dichroism, absorption, and fluorescence spectroscopy

    NASA Astrophysics Data System (ADS)

    Lee, Geon Joon; Sim, Geon Bo; Choi, Eun Ha; Kwon, Young-Wan; Kim, Jun Young; Jang, Siun; Kim, Seong Hwan

    2015-01-01

    To understand the killing mechanism of fungal spores by plasma treatment, the optical, structural, and biological properties of the insect pathogenic fungus Cordyceps bassiana spores were studied. A nonthermal atmospheric-pressure plasma jet (APPJ) was used to treat the spores in aqueous solution. Optical emission spectra of the APPJ acquired in air indicated emission peaks corresponding to hydroxyl radicals and atomic oxygen. When the APPJ entered the aqueous solution, additional reactive species were derived from the interaction of plasma radicals with the aqueous solution. Fluorescence and absorption spectroscopy confirmed the generation of hydroxyl radicals and hydrogen peroxide in the plasma-activated water (PAW). Spore counting showed that plasma treatment significantly reduced spore viability. Absorption spectroscopy, circular dichroism (CD) spectroscopy, and agarose gel electrophoresis of the DNA extracted from plasma-treated spores showed a reduction in spore DNA content. The magnitude of the dip in the CD spectrum was lower in the plasma-treated spores than in the control, indicating that plasma treatment causes structural modifications and/or damage to cellular components. Tryptophan fluorescence intensity was lower in the plasma-treated spores than in the control, suggesting that plasma treatment modified cell wall proteins. Changes in spore viability and DNA content were attributed to structural modification of the cell wall by reactive species coming from the APPJ and the PAW. Our results provided evidence that the plasma radicals and the derived reactive species play critical roles in fungal spore inactivation.

  7. Desizing of Starch Containing Cotton Fabrics Using Near Atmospheric Pressure, Cold DC Plasma Treatment

    NASA Astrophysics Data System (ADS)

    Prasath, A.; Sivaram, S. S.; Vijay Anand, V. D.; Dhandapani, Saravanan

    2013-03-01

    An attempt has been made to desize the starch containing grey cotton fabrics using the DC plasma with oxygen as the gaseous medium. Process conditions of the plasma reactor were optimized in terms of distance between the plates (3.2 cm), applied voltage (600 V) and applied pressure (0.01 bar) to obtain maximum desizing efficiency. No discolouration was observed in the hot water extracts of the desized sample in presence of iodine though relatively higher solvent extractable impurities (4.53 %) were observed in the plasma desized samples compared to acid desized samples (3.38 %). Also, significant weight loss, improvements in plasma desized samples were observed than that of grey fabrics in terms of drop absorbency.

  8. Determination of benzocaine in rainbow trout plasma

    USGS Publications Warehouse

    Bernardy, Jeffery A.; Coleman, K.S.; Stehly, G.R.; Gingerich, William H.

    1996-01-01

    A liquid chromatographic method is described for analysis of benzocaine (BZ), a proposed fish anesthetic, in rainbow trout plasma, Mean recoveries of BZ from plasma samples fortified at 44-10 100 ng/mL were 96-100%. The method detection limit is 10 ng/mL, and the limit of quantitation is 37 ng/mL. Acetylation of BZ occurs in whole blood after storage at room temperature (i.e., 21 degrees C) for 10 min. However, no acetylation of BZ was detected in plasma samples held at room temperature for 4 h, Mean method precision for plasma samples with incurred BZ residue is similar to that for fortified samples in the same concentration range (relative standard deviations of 0.9 and 1.2%, respectively).

  9. Endothelial- and Platelet-Derived Microparticles Are Generated During Liver Resection in Humans.

    PubMed

    Banz, Yara; Item, Gian-Marco; Vogt, Andreas; Rieben, Robert; Candinas, Daniel; Beldi, Guido

    2016-01-01

    Cell-derived plasma microparticles (<1.5 μm) originating from various cell types have the potential to regulate thrombogenesis and inflammatory responses. The aim of this study was to test the hypothesis that microparticles generated during hepatic surgery co-regulate postoperative procoagulant and proinflammatory events. In 30 patients undergoing liver resection, plasma microparticles were isolated, quantitated, and characterized as endothelial (CD31+, CD41-), platelet (CD41+), or leukocyte (CD11b+) origin by flow cytometry and their procoagulant and proinflammatory activity was measured by immunoassays. During liver resection, the total numbers of microparticles increased with significantly more Annexin V-positive, endothelial and platelet-derived microparticles following extended hepatectomy compared to standard and minor liver resections. After liver resection, microparticle tissue factor and procoagulant activity increased along with overall coagulation as assessed by thrombelastography. Levels of leukocyte-derived microparticles specifically increased in patients with systemic inflammation as assessed by C-reactive protein but are independent of the extent of liver resection. Endothelial and platelet-derived microparticles are specifically elevated during liver resection, accompanied by increased procoagulant activity. Leukocyte-derived microparticles are a potential marker for systemic inflammation. Plasma microparticles may represent a specific response to surgical stress and may be an important mediator of postoperative coagulation and inflammation.

  10. A random sampling approach for robust estimation of tissue-to-plasma ratio from extremely sparse data.

    PubMed

    Chu, Hui-May; Ette, Ene I

    2005-09-02

    his study was performed to develop a new nonparametric approach for the estimation of robust tissue-to-plasma ratio from extremely sparsely sampled paired data (ie, one sample each from plasma and tissue per subject). Tissue-to-plasma ratio was estimated from paired/unpaired experimental data using independent time points approach, area under the curve (AUC) values calculated with the naïve data averaging approach, and AUC values calculated using sampling based approaches (eg, the pseudoprofile-based bootstrap [PpbB] approach and the random sampling approach [our proposed approach]). The random sampling approach involves the use of a 2-phase algorithm. The convergence of the sampling/resampling approaches was investigated, as well as the robustness of the estimates produced by different approaches. To evaluate the latter, new data sets were generated by introducing outlier(s) into the real data set. One to 2 concentration values were inflated by 10% to 40% from their original values to produce the outliers. Tissue-to-plasma ratios computed using the independent time points approach varied between 0 and 50 across time points. The ratio obtained from AUC values acquired using the naive data averaging approach was not associated with any measure of uncertainty or variability. Calculating the ratio without regard to pairing yielded poorer estimates. The random sampling and pseudoprofile-based bootstrap approaches yielded tissue-to-plasma ratios with uncertainty and variability. However, the random sampling approach, because of the 2-phase nature of its algorithm, yielded more robust estimates and required fewer replications. Therefore, a 2-phase random sampling approach is proposed for the robust estimation of tissue-to-plasma ratio from extremely sparsely sampled data.

  11. Neuronal pentraxin 1: A synaptic-derived plasma biomarker in Alzheimer's disease.

    PubMed

    Ma, Qiu-Lan; Teng, Edmond; Zuo, Xiaohong; Jones, Mychica; Teter, Bruce; Zhao, Evan Y; Zhu, Cansheng; Bilousova, Tina; Gylys, Karen H; Apostolova, Liana G; LaDu, Mary Jo; Hossain, Mir Ahamed; Frautschy, Sally A; Cole, Gregory M

    2018-06-01

    Synaptic neurodegeneration is thought to be an early event initiated by soluble β-amyloid (Aβ) aggregates that closely correlates with cognitive decline in Alzheimer disease (AD). Apolipoprotein ε4 (APOE4) is the most common genetic risk factor for both familial AD (FAD) and sporadic AD; it accelerates Aβ aggregation and selectively impairs glutamate receptor function and synaptic plasticity. However, its molecular mechanisms remain elusive and these synaptic deficits are difficult to monitor. AD- and APOE4-dependent plasma biomarkers have been proposed, but synapse-related plasma biomarkers are lacking. We evaluated neuronal pentraxin 1 (NP1), a potential CNS-derived plasma biomarker of excitatory synaptic pathology. NP1 is preferentially expressed in brain and involved in glutamate receptor internalization. NP1 is secreted presynaptically induced by Aβ oligomers, and implicated in excitatory synaptic and mitochondrial deficits. Levels of NP1 and its fragments were increased in a correlated fashion in both brain and plasma of 7-8 month-old E4FAD mice relative to E3FAD mice. NP1 was also found in exosome preparations and reduced by dietary DHA supplementation. Plasma NP1 was higher in E4FAD+ (APOE4 +/+ /FAD +/- ) relative to E4FAD- (non-carrier; APOE4 +/+ /FAD -/- ) mice, suggesting NP1 is modulated by Aβ expression. Finally, relative to normal elderly, plasma NP1 was also elevated in patients with mild cognitive impairment (MCI) and elevated further in the subset who progressed to early-stage AD. In those patients, there was a trend towards increased NP1 levels in APOE4 carriers relative to non-carriers. These findings indicate that NP1 may represent a potential synapse-derived plasma biomarker relevant to early alterations in excitatory synapses in MCI and early-stage AD. Copyright © 2018. Published by Elsevier Inc.

  12. Hydrodynamic and kinetic models for spin-1/2 electron-positron quantum plasmas: Annihilation interaction, helicity conservation, and wave dispersion in magnetized plasmas

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Andreev, Pavel A., E-mail: andreevpa@physics.msu.ru

    2015-06-15

    We discuss the complete theory of spin-1/2 electron-positron quantum plasmas, when electrons and positrons move with velocities mach smaller than the speed of light. We derive a set of two fluid quantum hydrodynamic equations consisting of the continuity, Euler, spin (magnetic moment) evolution equations for each species. We explicitly include the Coulomb, spin-spin, Darwin and annihilation interactions. The annihilation interaction is the main topic of the paper. We consider the contribution of the annihilation interaction in the quantum hydrodynamic equations and in the spectrum of waves in magnetized electron-positron plasmas. We consider the propagation of waves parallel and perpendicular tomore » an external magnetic field. We also consider the oblique propagation of longitudinal waves. We derive the set of quantum kinetic equations for electron-positron plasmas with the Darwin and annihilation interactions. We apply the kinetic theory to the linear wave behavior in absence of external fields. We calculate the contribution of the Darwin and annihilation interactions in the Landau damping of the Langmuir waves. We should mention that the annihilation interaction does not change number of particles in the system. It does not related to annihilation itself, but it exists as a result of interaction of an electron-positron pair via conversion of the pair into virtual photon. A pair of the non-linear Schrodinger equations for the electron-positron plasmas including the Darwin and annihilation interactions is derived. Existence of the conserving helicity in electron-positron quantum plasmas of spinning particles with the Darwin and annihilation interactions is demonstrated. We show that the annihilation interaction plays an important role in the quantum electron-positron plasmas giving the contribution of the same magnitude as the spin-spin interaction.« less

  13. BINARY CORRELATIONS IN IONIZED GASES

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Balescu, R.; Taylor, H.S.

    1961-01-01

    An equation of evolution for the binary distribution function in a classical homogeneous, nonequilibrium plasma was derived. It is shown that the asymptotic (long-time) solution of this equation is the Debye distribution, thus providing a rigorous dynamical derivation of the equilibrium distribution. This proof is free from the fundamental conceptual difficulties of conventional equilibrium derivations. Out of equilibrium, a closed formula was obtained for the long living correlations, in terms of the momentum distribution function. These results should form an appropriate starting point for a rigorous theory of transport phenomena in plasmas, including the effect of molecular correlations. (auth)

  14. Label-free quantitative proteomic analysis of human plasma-derived microvesicles to find protein signatures of abdominal aortic aneurysms.

    PubMed

    Martinez-Pinna, Roxana; Gonzalez de Peredo, Anne; Monsarrat, Bernard; Burlet-Schiltz, Odile; Martin-Ventura, Jose Luis

    2014-08-01

    To find potential biomarkers of abdominal aortic aneurysms (AAA), we performed a differential proteomic study based on human plasma-derived microvesicles. Exosomes and microparticles isolated from plasma of AAA patients and control subjects (n = 10 each group) were analyzed by a label-free quantitative MS-based strategy. Homemade and publicly available software packages have been used for MS data analysis. The application of two kinds of bioinformatic tools allowed us to find differential protein profiles from AAA patients. Some of these proteins found by the two analysis methods belong to main pathological mechanisms of AAA such as oxidative stress, immune-inflammation, and thrombosis. Data analysis from label-free MS-based experiments requires the use of sophisticated bioinformatic approaches to perform quantitative studies from complex protein mixtures. The application of two of these bioinformatic tools provided us a preliminary list of differential proteins found in plasma-derived microvesicles not previously associated to AAA, which could help us to understand the pathological mechanisms related to this disease. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  15. Effect of strenuous physical exercise on circulating cell-derived microparticles.

    PubMed

    Chaar, Vicky; Romana, Marc; Tripette, Julien; Broquere, Cédric; Huisse, Marie-Geneviève; Hue, Olivier; Hardy-Dessources, Marie-Dominique; Connes, Philippe

    2011-01-01

    Strenuous exercise is associated with an inflammatory response involving the activation of several types of blood cells. In order to document the specific activation of these cell types, we studied the effect of three maximal exercise tests conducted to exhaustion on the quantitative and qualitative pattern of circulating cell-derived microparticles and inflammatory molecules in healthy subjects. This study mainly indicated that the plasma concentration of microparticles from platelets and polymorphonuclear neutrophils (PMN) was increased immediately after the strenuous exercise. In addition, the increase in plasma concentration of microparticles from PMN and platelets was still observed after 2 hours of recovery. A similar pattern was observed for the IL-6 plasma level. In contrast, no change was observed for either soluble selectins or plasma concentration of microparticles from red blood cells, monocytes and endothelial cells. In agreement, sVCAM-1 and sICAM-1 levels were not changed by the exercise. We conclude that a strenuous exercise is accompanied by platelet- and PMN-derived microparticle production that probably reflects the activation of these two cell types.

  16. A randomised cross-over pharmacokinetic bioavailability study of synthetic versus kiwifruit-derived vitamin C.

    PubMed

    Carr, Anitra C; Bozonet, Stephanie M; Vissers, Margreet C M

    2013-11-11

    Kiwifruit are a rich source of vitamin C and also contain numerous phytochemicals, such as flavonoids, which may influence the bioavailability of kiwifruit-derived vitamin C. The aim of this study was to compare the relative bioavailability of synthetic versus kiwifruit-derived vitamin C using a randomised cross-over pharmacokinetic study design. Nine non-smoking males (aged 18-35 years) received either a chewable tablet (200 mg vitamin C) or the equivalent dose from gold kiwifruit (Actinidia chinensis var. Sungold). Fasting blood and urine were collected half hourly to hourly over the eight hours following intervention. The ascorbate content of the plasma and urine was determined using HPLC with electrochemical detection. Plasma ascorbate levels increased from 0.5 h after the intervention (P = 0.008). No significant differences in the plasma time-concentration curves were observed between the two interventions (P = 0.645). An estimate of the total increase in plasma ascorbate indicated complete uptake of the ingested vitamin C tablet and kiwifruit-derived vitamin C. There was an increase in urinary ascorbate excretion, relative to urinary creatinine, from two hours post intervention (P < 0.001). There was also a significant difference between the two interventions, with enhanced ascorbate excretion observed in the kiwifruit group (P = 0.016). Urinary excretion was calculated as ~40% and ~50% of the ingested dose from the vitamin C tablet and kiwifruit arms, respectively. Overall, our pharmacokinetic study has shown comparable relative bioavailability of kiwifruit-derived vitamin C and synthetic vitamin C.

  17. A needle extraction utilizing a molecularly imprinted-sol-gel xerogel for on-line microextraction of the lung cancer biomarker bilirubin from plasma and urine samples.

    PubMed

    Moein, Mohammad Mahdi; Jabbar, Dunia; Colmsjö, Anders; Abdel-Rehim, Mohamed

    2014-10-31

    In the present work, a needle trap utilizing a molecularly imprinted sol-gel xerogel was prepared for the on-line microextraction of bilirubin from plasma and urine samples. Each prepared needle could be used for approximately one hundred extractions before it was discarded. Imprinted and non-imprinted sol-gel xerogel were applied for the extraction of bilirubin from plasma and urine samples. The produced molecularly imprinted sol-gel xerogel polymer showed high binding capacity and fast adsorption/desorption kinetics for bilirubin in plasma and urine samples. The adsorption capacity of molecularly imprinted sol-gel xerogel polymer was approximately 60% higher than that of non-imprinted polymer. The effect of the conditioning, washing and elution solvents, pH, extraction time, adsorption capacity and imprinting factor were investigated. The limit of detection and the lower limit of quantification were set to 1.6 and 5nmolL(-1), respectively using plasma or urine samples. The standard calibration curves were obtained within the concentration range of 5-1000nmolL(-1) in both plasma and urine samples. The coefficients of determination values (R(2)) were ≥0.998 for all runs. The extraction recovery was approximately 80% for BR in the human plasma and urine samples. Copyright © 2014 Elsevier B.V. All rights reserved.

  18. von Kármán-Howarth equation for three-dimensional two-fluid plasmas.

    PubMed

    Andrés, N; Mininni, P D; Dmitruk, P; Gómez, D O

    2016-06-01

    We derive the von Kármán-Howarth equation for a full three-dimensional incompressible two-fluid plasma. In the long-time limit and for very large Reynolds numbers we obtain the equivalent of the hydrodynamic "four-fifths" law. This exact law predicts the scaling of the third-order two-point correlation functions, and puts a strong constraint on the plasma turbulent dynamics. Finally, we derive a simple expression for the 4/5 law in terms of third-order structure functions, which is appropriate for comparison with in situ measurements in the solar wind at different spatial ranges.

  19. Stopping power: Effect of the projectile deceleration

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kompaneets, Roman, E-mail: kompaneets@mpe.mpg.de; Ivlev, Alexei V.; Morfill, Gregor E.

    2014-11-15

    The stopping force is the force exerted on the projectile by its wake. Since the wake does not instantly adjust to the projectile velocity, the stopping force should be affected by the projectile deceleration caused by the stopping force itself. We address this effect by deriving the corresponding correction to the stopping force in the cold plasma approximation. By using the derived expression, we estimate that if the projectile is an ion passing through an electron-proton plasma, the correction is small when the stopping force is due to the plasma electrons, but can be significant when the stopping force ismore » due to the protons.« less

  20. Current collection in an anisotropic plasma

    NASA Technical Reports Server (NTRS)

    Li, Wei-Wei

    1990-01-01

    A general method is given to derive the current-potential relations in anisotropic plasmas. Orbit limit current is assumed. The collector is a conductive sphere or an infinite cylinder. Any distribution which is an arbitrary function of the velocity vector can be considered as a superposition of many mono-energetic beams whose current-potential relations are known. The results for two typical pitch angle distributions are derived and discussed in detail. The general properties of the current potential relations are very similar to that of a Maxwellian plasma except for an effective temperature which varies with the angle between the magnetic field and the charging surface. The conclusions are meaningful to generalized geometries.

  1. Electrostatic and electromagnetic gyroharmonic emissions due to energetic electrons in magnetospheric plasma

    NASA Technical Reports Server (NTRS)

    Curtis, S. A.; Wu, C. S.

    1979-01-01

    The paper derives the growth rates and growth lengths of the electrostatic emission for spatially homogeneous and inhomogeneous energetic electrons, and numerically evaluates the growth rate and growth length spectra for several parameter sets representative of magnetospheric plasmas. In addition, the growth rates are derived for the case of electromagnetic emission modeled by the ordinary mode. The numerical results of the electromagnetic and electrostatic cases are compared with observations made by satellites in the earth's magnetosphere. It is concluded that the electrostatic gyroharmonic excitation is possible without the cold composition of plasma which is often postulated in the existing literature.

  2. The effects of RF plasma ashing on zinc orthotitanate/potassium silicate thermal control coatings

    NASA Technical Reports Server (NTRS)

    Dever, Joyce A.; Bruckner, Eric J.

    1992-01-01

    Samples of YB-71, a white thermal control coating composed of zinc orthotitanate pigment in a potassium silicate binder, were exposed in air plasma and in oxygen plasma to determine optical property and surface chemistry changes. Results show that YB-71 undergoes a significant reflectance decrease upon exposure to the simulated LEO atomic oxygen environment provided by an air plasma asher. YB-71 samples exposed to the same effective fluence in oxygen plasma, or in a UV screening Faraday cage in air or oxygen, do not undergo as severe reflectance decreases as the samples exposed in the air plasma asher environment. The UV and VUV radiation present in the plasma ashers affects the YB-71 degradation. It is noted that, when using plasma ashers to determine LEO degradation, it is necessary to take into account the sensitivity of the material to the synergistic effects of atomic oxygen and accelerated UV radiation.

  3. Closed inductively coupled plasma cell

    DOEpatents

    Manning, Thomas J.; Palmer, Byron A.; Hof, Douglas E.

    1990-01-01

    A closed inductively coupled plasma cell generates a relatively high power, low noise plasma for use in spectroscopic studies. A variety of gases can be selected to form the plasma to minimize spectroscopic interference and to provide a electron density and temperature range for the sample to be analyzed. Grounded conductors are placed at the tube ends and axially displaced from the inductive coil, whereby the resulting electromagnetic field acts to elongate the plasma in the tube. Sample materials can be injected in the plasma to be excited for spectroscopy.

  4. Comparison of serum and plasma measurements of Müllerian inhibiting substance.

    PubMed

    Merhi, Zaher O; Messerlian, Geralyn M; Minkoff, Howard; Eklund, Elizabeth E; Macura, Jerzy; Feldman, Joseph; Rodriguez, Carlos; Seifer, David B

    2008-06-01

    The authors sought to determine whether measurement of plasma Müllerian inhibiting substance (MIS) is a suitable substitute for measurement of serum MIS. Eighteen samples of serum and plasma were examined that were drawn simultaneously. Levels of MIS were measured with an ELISA kit, and plasma levels were studied in parallel to serum samples. A 98.5% correlation was found between serum and plasma MIS values.

  5. Cortisol in saliva and plasma of cattle after ACTH administration and milking.

    PubMed

    Negrão, J A; Porcionato, M A; de Passillé, A M; Rushen, J

    2004-06-01

    Interest in the measurement of salivary cortisol has increased recently because saliva can be easily collected before and after an imposed stress. This study evaluated the relationship between plasma and salivary concentrations of cortisol following ACTH administration in calves (experiment 1) and machine milking of adult cows (experiment 2). A catheter was inserted into the jugular vein of all animals 72 h before the beginning of experiments. Blood and saliva samples were collected before and after ACTH administration (0.6 IU/kg BW) in calves or before and after machine milking of cows. Using a cotton swab, each saliva sample was taken immediately following the blood sample. In general, cortisol profiles were similar in plasma and saliva and correlated in both experiments; however, plasma concentrations were significantly higher than salivary concentrations. In addition, the differences between cortisol concentrations measured in saliva and plasma within each experiment varied substantially between animals and samples. Furthermore, in experiment 2, nearly 10% of salivary samples were below limits of detection. The sharp peaks in cortisol after ACTH administration in both the plasma and saliva were reflected adrenal stimulation. In addition, increases in cortisol in response to milking in both the plasma and saliva suggest that salivary sampling is a reliable option when studying cortisol responses to normal physiological events.

  6. Capillary whole blood testing by a new portable monitor. Comparison with standard determination of the international normalized ratio.

    PubMed

    de Miguel, Dunia; Burgaleta, Carmen; Reyes, Eduardo; Pascual, Teresa

    2003-07-01

    We evaluated a new portable monitor (AvoSure PT PRO, Menarini Diagnostics, Firenze, Italy) developed to test the prothrombin time in capillary blood and plasma by comparing it with the standard laboratory determination. We studied 62 patients receiving acenocoumarol therapy. The international normalized ratio (INR) in capillary blood was analyzed by 2 methods: AvoSure PT PRO and Thrombotrack Nycomed Analyzer (Axis-Shield, Dundee, Scotland). Parallel studies were performed in plasma samples by a reference method using the Behring Coagulation Timer (Behring Diagnostics, Marburg, Germany). Plasma samples also were tested with the AvoSure PT PRO. Correlation was good for INR values for capillary blood and plasma samples by AvoSure PT PRO and our reference method (R2 = 0.8596) and for capillary blood samples tested by the AvoSure PT PRO and Thrombotrack Nycomed Analyzer (R2 = 0.8875). The correlation for INR in capillary blood and plasma samples by AvoSure PT PRO was 0.6939 (P < .0004). Capillary blood determinations are rapid and effective for monitoring oral anticoagulation therapy and have a high correlation to plasma determinations. AvoSure PT PRO is accurate for controlling INR in plasma and capillary blood samples, may be used in outpatient clinics, and has advantages over previous portable monitors.

  7. Comparison of plasma and tissue samples in epidermal growth factor receptor mutation by ARMS in advanced non-small cell lung cancer.

    PubMed

    Ma, MeiLi; Shi, ChunLei; Qian, JiaLin; Teng, JiaJun; Zhong, Hua; Han, BaoHui

    2016-10-10

    The aim of this study was to assess the effectiveness and accuracy of blood-based circulating-free tumor DNA on testing epidermal growth factor receptor (EGFR) gene mutations. In total, 219 non-small cell lung cancer patients in stages III-IV were enrolled into this study. All patients had tissue samples and matched plasma DNA samples. EGFR gene mutations were detected by the Amplification Refractory Mutation System (ARMS). We compared the mutations in tumor tissue samples with matched plasma samples and determined the correlation between EGFR mutation status and clinical pathologic characteristics. The overall concordance rate of EGFR mutation status between the 219 matched plasma and tissue samples was 82% (179/219). The sensitivity and specificity for the ARMS EGFR mutation test in the plasma compared with tumor tissue were 60% (54/90) and 97% (125/129), respectively. The positive predictive value was 93% (54/58) and the negative predictive value was 78% (125/161). The median overall survival was longer for those with EGFR mutations than for those without EGFR mutations both in tissue samples (23.98 vs. 12.16months; P<0.001) and in plasma (19.96 vs. 13.63months; P=0.009). For the 68 patients treated with EGFR- tyrosine kinase inhibitors (TKIs), the median progression-free survival (PFS) was significantly prolonged in the EGFR mutant group compared to the non-mutation group in tumor tissue samples (12.26months vs. 2.40months, P<0.001). In plasma samples, the PFS of the mutant group was longer than that of the non-mutant group. However, there was no significant difference between the two groups (10.88months vs. 9.89months, P=0.411). The detection of EGFR mutations in plasma using ARMS is relatively sensitive and highly specific. However, EGFR mutation status tested by ARMS in plasma cannot replace a tumor tissue biopsy. Positive EGFR mutation results detected in plasma are fairly reliable, but negative results are hampered by a high rate of false negatives. Copyright © 2016. Published by Elsevier B.V.

  8. Lack of an association of BDNF Val66Met polymorphism and plasma BDNF with hippocampal volume and memory

    PubMed Central

    Kim, Ana; Fagan, Anne M; Goate, Alison M; Benzinger, Tammie LS; Morris, John C; Head, Denise

    2015-01-01

    Brain-derived neurotrophic factor (BDNF) has been shown to be important for neuronal survival and synaptic plasticity in the hippocampus in non-human animals. The Val66Met polymorphism in the BDNF gene, involving a valine (Val) to methionine (Met) substitution at codon 66, has been associated with lower BDNF secretion in vitro. However, there have been mixed results regarding associations between either circulating BDNF or the BDNF Val66Met polymorphism with hippocampal volume and memory in humans. The current study examined the association of BDNF genotype and plasma BDNF with hippocampal volume and memory in two large independent cohorts of middle-aged and older adults (both cognitively normal and early-stage dementia). Sample sizes ranged from 123 to 649. Measures of the BDNF genotype, plasma BDNF, MRI-based hippocampal volume and memory performance were obtained from the Knight Alzheimer Disease Research Center (ADRC) and the Alzheimer’s Disease Neuroimaging Initiative (ADNI). There were no significant differences between BDNF Met+ and Met- groups on either hippocampal volume or memory in either cohort. In addition, plasma BDNF was not significantly associated with either hippocampal volume or memory in either cohort. Neither age, cognitive status nor gender moderated any of the relationships. Overall, current findings suggest that BDNF genotype and plasma BDNF may not be robust predictors for variance in hippocampal volume and memory in middle age and older adult cohorts. PMID:25784293

  9. Polyphenols from Berries of Aronia melanocarpa Reduce the Plasma Lipid Peroxidation Induced by Ziprasidone

    PubMed Central

    Dietrich-Muszalska, Anna; Kopka, Justyna

    2014-01-01

    Background. Oxidative stress in schizophrenia may be caused partially by the treatment of patients with antipsychotics. The aim of the study was to establish the effects of polyphenol compounds derived from berries of Aronia melanocarpa (Aronox) on the plasma lipid peroxidation induced by ziprasidone in vitro. Methods. Lipid peroxidation was measured by the level of thiobarbituric acid reactive species (TBARS). The samples of plasma from healthy subjects were incubated with ziprasidone (40 ng/ml; 139 ng/ml; and 250 ng/ml) alone and with Aronox (5 ug/ml; 50 ug/ml). Results. We observed a statistically significant increase of TBARS level after incubation of plasma with ziprasidone (40 ng/ml; 139 ng/ml; and 250 ng/ml) (after 24 h incubation: P = 7.0 × 10−4, P = 1.6 × 10−3, and P = 2.7 × 10−3, resp.) and Aronox lipid peroxidation caused by ziprasidone was significantly reduced. After 24-hour incubation of plasma with ziprasidone (40 ng/ml; 139 ng/ml; and 250 ng/ml) in the presence of 50 ug/ml Aronox, the level of TBARS was significantly decreased: P = 6.5 × 10−8, P = 7.0 × 10−6, and P = 3.0 × 10−5, respectively. Conclusion. Aronox causes a distinct reduction of lipid peroxidation induced by ziprasidone. PMID:25061527

  10. Highly sensitive spectrofluorimetric determination of lomefloxacin in spiked human plasma, urine and pharmaceutical preparations.

    PubMed

    Ulu, Sevgi Tatar

    2009-09-01

    A sensitive, simple and selective spectrofluorimetric method was developed for the determination of lomefloxacin in biological fluids and pharmaceutical preparations. The method is based on the reaction between the drug and 4-chloro-7-nitrobenzodioxazole in borate buffer of pH 8.5 to yield a highly fluorescent derivative that is measured at 533 nm after excitation at 433 nm. The calibration curves were linear over the concentration ranges of 12.5-625, 15-1500 and 20-2000 ng/mL for plasma, urine and standard solution, respectively. The limits of detection were 4.0 ng/mL in plasma, 5.0 ng/mL in urine and 7.0 ng/mL in standard solution. The intra-assay accuracy and precision in plasma ranged from 0.032 to 2.40% and 0.23 to 0.36%, respectively, while inter-assay accuracy and precision ranged from 0.45 to 2.10% and 0.25 to 0.38%, respectively. The intra-assay accuracy and precision estimated on spiked samples in urine ranged from 1.27 to 4.20% and 0.12 to 0.24%, respectively, while inter-assay accuracy and precision ranged from 1.60 to 4.00% and 0.14 to 0.25%, respectively. The mean recovery of lomefloxacin from plasma and urine was 98.34 and 98.43%, respectively. The method was successfully applied to the determination of lomefloxacin in pharmaceuticals and biological fluids.

  11. The Use of Dried Blood Spots for Pharmacokinetic Monitoring of Vemurafenib Treatment in Melanoma Patients.

    PubMed

    Nijenhuis, Cynthia M; Huitema, Alwin D R; Marchetti, Serena; Blank, Christian; Haanen, John B A G; van Thienen, Johannes V; Rosing, Hilde; Schellens, Jan H M; Beijnen, Jos H

    2016-10-01

    Pharmacokinetic monitoring is increasingly becoming an important part of clinical care of tyrosine kinase inhibitor treatment. Vemurafenib is an oral tyrosine kinase inhibitor that inhibits mutated serine/threonine protein kinase B-Raf (BRAF) and is approved for the treatment of adult patients with BRAF V600 mutation-positive unresectable or metastatic melanoma. The aim of this study was to establish the relationship between dried blood spot (DBS) and plasma concentrations of vemurafenib to enable the use of DBS sampling, which is a minimally invasive form of sample collection. In total, 43 paired plasma and DBS samples (in duplicate) were obtained from 8 melanoma patients on vemurafenib therapy and were analyzed using high-performance liquid chromatography-tandem mass spectrometry. Plasma concentrations were predicted from the DBS concentrations using 2 methods: (1) individual hematocrit correction and blood cell-to-plasma partitioning and (2) the calculated slope explaining the relationship between DBS and plasma concentrations (without individual hematocrit correction). Vemurafenib DBS concentrations and plasma concentrations showed a strong correlation (r = 0.964), and the relationship could be described by ([vemurafenib]plasma = [vemurafenib]DBS /0.64). The predicted plasma concentrations were within ±20% of the analyzed plasma concentrations in 97% and 100% of the samples for the methods with and without hematocrit correction, respectively. In conclusion, DBS concentrations and plasma concentrations of vemurafenib are highly correlated. Plasma concentrations can be predicted from DBS concentration using the blood cell-to-plasma partition and the average hematocrit value of this cohort (0.40 L/L). DBS sampling for pharmacokinetic monitoring of vemurafenib treatment can be used in clinical practice. © 2016, The American College of Clinical Pharmacology.

  12. Sweat Facilitated Amino Acid Losses in Male Athletes during Exercise at 32-34°C.

    PubMed

    Dunstan, R Hugh; Sparkes, Diane L; Dascombe, Benjamin J; Macdonald, Margaret M; Evans, Craig A; Stevens, Christopher J; Crompton, Marcus J; Gottfries, Johan; Franks, Jesse; Murphy, Grace; Wood, Ryan; Roberts, Timothy K

    2016-01-01

    Sweat contains amino acids and electrolytes derived from plasma and athletes can lose 1-2L of sweat per hour during exercise. Sweat may also contain contributions of amino acids as well as urea, sodium and potassium from the natural moisturizing factors (NMF) produced in the stratum corneum. In preliminary experiments, one participant was tested on three separate occasions to compare sweat composition with surface water washings from the same area of skin to assess contributions from NMF. Two participants performed a 40 minute self-paced cycle session with sweat collected from cleansed skin at regular intervals to assess the contributions to the sweat load from NMF over the period of exercise. The main study investigated sweat amino acid composition collected from nineteen male athletes following standardised endurance exercise regimes at 32-34°C and 20-30% RH. Plasma was also collected from ten of the athletes to compare sweat and plasma composition of amino acids. The amino acid profiles of the skin washings were similar to the sweat, suggesting that the NMF could contribute certain amino acids into sweat. Since the sweat collected from athletes contained some amino acid contributions from the skin, this fluid was subsequently referred to as "faux" sweat. Samples taken over 40 minutes of exercise showed that these contributions diminished over time and were minimal at 35 minutes. In the main study, the faux sweat samples collected from the athletes with minimal NMF contributions, were characterised by relatively high levels of serine, histidine, ornithine, glycine and alanine compared with the corresponding levels measured in the plasma. Aspartic acid was detected in faux sweat but not in the plasma. Glutamine and proline were lower in the faux sweat than plasma in all the athletes. Three phenotypic groups of athletes were defined based on faux sweat volumes and composition profiles of amino acids with varying relative abundances of histidine, serine, glycine and ornithine. It was concluded that for some individuals, faux sweat resulting from exercise at 32-34°C and 20-30% RH posed a potentially significant source of amino acid loss.

  13. Sweat Facilitated Amino Acid Losses in Male Athletes during Exercise at 32-34°C

    PubMed Central

    Dunstan, R. Hugh; Sparkes, Diane L.; Dascombe, Benjamin J.; Macdonald, Margaret M.; Evans, Craig A.; Stevens, Christopher J.; Crompton, Marcus J.; Gottfries, Johan; Franks, Jesse; Murphy, Grace; Wood, Ryan; Roberts, Timothy K.

    2016-01-01

    Sweat contains amino acids and electrolytes derived from plasma and athletes can lose 1-2L of sweat per hour during exercise. Sweat may also contain contributions of amino acids as well as urea, sodium and potassium from the natural moisturizing factors (NMF) produced in the stratum corneum. In preliminary experiments, one participant was tested on three separate occasions to compare sweat composition with surface water washings from the same area of skin to assess contributions from NMF. Two participants performed a 40 minute self-paced cycle session with sweat collected from cleansed skin at regular intervals to assess the contributions to the sweat load from NMF over the period of exercise. The main study investigated sweat amino acid composition collected from nineteen male athletes following standardised endurance exercise regimes at 32–34°C and 20–30% RH. Plasma was also collected from ten of the athletes to compare sweat and plasma composition of amino acids. The amino acid profiles of the skin washings were similar to the sweat, suggesting that the NMF could contribute certain amino acids into sweat. Since the sweat collected from athletes contained some amino acid contributions from the skin, this fluid was subsequently referred to as “faux” sweat. Samples taken over 40 minutes of exercise showed that these contributions diminished over time and were minimal at 35 minutes. In the main study, the faux sweat samples collected from the athletes with minimal NMF contributions, were characterised by relatively high levels of serine, histidine, ornithine, glycine and alanine compared with the corresponding levels measured in the plasma. Aspartic acid was detected in faux sweat but not in the plasma. Glutamine and proline were lower in the faux sweat than plasma in all the athletes. Three phenotypic groups of athletes were defined based on faux sweat volumes and composition profiles of amino acids with varying relative abundances of histidine, serine, glycine and ornithine. It was concluded that for some individuals, faux sweat resulting from exercise at 32–34°C and 20–30% RH posed a potentially significant source of amino acid loss. PMID:27936120

  14. Plasma discharge elemental detector for a mass spectrometer

    NASA Astrophysics Data System (ADS)

    Heppner, R. A.

    1983-06-01

    A material to be analyzed is injected into a mirowave-induced plasma discharge unit, in which the material is carried with a flow of buffer gas through an intense microwave energy field which produces a plasma discharge in the buffer gas. As the material exits from the plasma discharge, the material is sampled and conveyed along a capillary transfer tube to a mass spectrometer where it is analyzed. The plasma discharge causes dissociation of complex organic molecules into simpler molecules which return to the neutral ground state before they are analyzed in the mass spectrometer. The buffer gas is supplied to one end portion of the discharge tube and is withdrawn from the other end portion by a vacuum pump which maintains a subatmospheric pressure in the discharge tube. The sample material is injected by a capillary injection tube into the buffer gas flow as it enters the plasma discharge zone. The dissociated materials are sampled by an axial sampling tube having an entrance where the buffer gas exits from the plasma discharge zone. The sample material may be supplied by a gas chromatography having a capillary effluent line connected to the capillary injection tube, so that the effluent material is injected into the microwave induced plasma discharge. The microwave field is produced by a cavity resonator through which the discharge tube passes.

  15. Pharmacokinetics of lopinavir/ritonavir and efavirenz in food insecure HIV-infected pregnant and breastfeeding women in Tororo, Uganda

    PubMed Central

    Bartelink, Imke H.; Savic, Rada M.; Mwesigwa, Julia; Achan, Jane; Clark, Tamara; Plenty, Albert; Charlebois, Edwin; Kamya, Moses; Young, Sera L.; Gandhi, Monica; Havlir, Diane; Cohan, Deborah; Aweeka, Francesca

    2013-01-01

    Pregnancy and food insecurity may impact antiretroviral (ART) pharmacokinetics (PK), adherence and response. We sought to quantify and characterize the PK of lopinavir/ritonavir (LPV/r) and efavirenz (EFV) by pregnancy and nutritional status among HIV-infected women in Tororo, Uganda. In 2011, 62/225 ante-partum/post-partum single dried blood spot samples DBS and 43 post-partum hair samples for LPV/r were derived from 116 women, 51/194 ante-/post-partum DBS and 53 post-partum hair samples for EFV from 105 women. 80% of Ugandan participants were severely food insecure, 26% lost weight ante-partum, and median BMI post-partum was only 20.2 kg/m2. Rich PK-data of normally nourished (pregnant) women and healthy Ugandans established prior information. Overall, drug exposure was reduced (LPV −33%, EFV −15%, ritonavir −17%) compared to well-nourished controls [p < 0.001], attributable to decreased bioavailability. Pregnancy increased LPV/r clearance 68% [p < 0.001], whereas EFV clearance remained unchanged. Hair concentrations correlated with plasma-exposure [p < 0.001], explaining 29% PK-variability. In conclusion, pregnancy and food insecurity were associated with lower ART exposures in this cohort of predominantly underweight women, compared to well-nourished women. Much variability in plasma-exposure was quantified using hair concentrations. Addressing malnutrition as well as ART-PK in this setting should be a priority. PMID:24038035

  16. Flow-Induced Dispersion Analysis for Probing Anti-dsDNA Antibody Binding Heterogeneity in Systemic Lupus Erythematosus Patients: Toward a New Approach for Diagnosis and Patient Stratification.

    PubMed

    Poulsen, Nicklas N; Pedersen, Morten E; Østergaard, Jesper; Petersen, Nickolaj J; Nielsen, Christoffer T; Heegaard, Niels H H; Jensen, Henrik

    2016-09-20

    Detection of immune responses is important in the diagnosis of many diseases. For example, the detection of circulating autoantibodies against double-stranded DNA (dsDNA) is used in the diagnosis of Systemic Lupus Erythematosus (SLE). It is, however, difficult to reach satisfactory sensitivity, specificity, and accuracy with established assays. Also, existing methodologies for quantification of autoantibodies are challenging to transfer to a point-of-care setting. Here we present the use of flow-induced dispersion analysis (FIDA) for rapid (minutes) measurement of autoantibodies against dsDNA. The assay is based on Taylor dispersion analysis (TDA) and is fully automated with the use of standard capillary electrophoresis (CE) based equipment employing fluorescence detection. It is robust toward matrix effects as demonstrated by the direct analysis of samples composed of up to 85% plasma derived from human blood samples, and it allows for flexible exchange of the DNA sequences used to probe for the autoantibodies. Plasma samples from SLE positive patients were analyzed using the new FIDA methodology as well as by standard indirect immunofluorescence and solid-phase immunoassays. Interestingly, the patient antibodies bound DNA sequences with different affinities, suggesting pronounced heterogeneity among autoantibodies produced in SLE. The FIDA based methodology is a new approach for autoantibody detection and holds promise for being used for patient stratification and monitoring of disease activity.

  17. The investigation of Al0.29Ga0.71N/GaN/AlN and AlN/GaN/AlN thin films grown on Si (111) by RF plasma-assisted MBE

    NASA Astrophysics Data System (ADS)

    Yusoff, Mohd Zaki Mohd; Mahyuddin, Azzafeerah; Hassan, Zainuriah; Hassan, Haslan Abu; Abdullah, Mat Johar

    2012-06-01

    Recently, gallium nitride (GaN) and its related compounds involving Al and In have attracted much attention because of their potential to be used as high-efficiency UV light emitting devices, and as high frequency and high power electronic devices. Consequently, the growth and physics of GaN-based materials have attracted remarkable scientific attention. In this work, the growth and characterization of epitaxial Al0.29Ga0.71N and AlN layers grown on Si (111) by RF-plasma assisted molecular beam epitaxy (MBE) are described. The Al mole fraction was derived from the HR-XRD symmetric rocking curve (RC) ω/2θ scans of (0002) plane as x = 0.29. For AlN/GaN/AlN sample, the maximum Raman intensity at 521.53 cm-1 is attributed to crystalline silicon. It was found that the allowed Raman optical phonon mode of GaN, the E1 (high) is clearly visible, which is located at 570.74 cm-1. Photoluminscence (PL) spectrums of both samples have shown sharp and intense band edge emission of GaN without the existence of yellow emission band, showing good crystal quality of the samples have been successfully grown on Si substrate.

  18. Activated partial thromboplastin time derivative curves: helpful diagnostic tool in mixing test interpretation.

    PubMed

    Esmedere Eren, Sevim; Karakukcu, Cigdem; Ciraci, Mehmet Z; Ustundag, Yasemin; Karakukcu, Musa

    2018-06-01

    : The mixing test is used to evaluate whether prolonged activated partial thromboplastin time (APTT) is due to an inhibitor or a factor deficiency. The coagulation reaction is demonstrated with APTT derivative curves on the ACL TOP series. We aimed to determine the utility of APTT derivative curves in the mixing test process. The plasma of a patient was mixed with normal plasma in a 1 : 1 ratio and APTT assay was performed with SynthASil reagent. We observed roughness, biphasic and shoulder patterns in derivative curves during the mixing test. An extended laboratory investigation revealed a positive lupus anticoagulant, low factors XI and IX activities. Along with mixing test cut-off limits, we recommend analysing changes in APTT derivative curves to minimize erroneous interpretations of the mixing test. Derivative curves display either a normalizing pattern in factor deficiencies or an atypical pattern in the presence of lupus anticoagulant.

  19. [Proliferation and osteogenic differentiation of mesenchymal stem cells in hydrogels of human blood plasma].

    PubMed

    Linero, Itali M; Doncel, Adriana; Chaparro, Orlando

    2014-01-01

    The use of mesenchymal stem cells in clinical practice has increased considerably in the last decade because they play a supporting role in the processes of tissue repair and regeneration, becoming the main tool of cell therapy for the treatment of diseases functionally affecting bone and cartilage tissue . To evaluate in vitro the proliferative and osteogenic differentiation ability of mesenchymal stem cells derived from human adipose tissue in a blood plasma hydrogel. Mesenchymal stem cells were obtained from human adipose tissue explants and characterized by flow cytometry. Their multipotentiality was demonstrated by their ability to differentiate to adipogenic and osteogenic lineages. Cell proliferation and osteogenic differentiation ability of the cells cultured in blood plasma hydrogels were also evaluated. Mesenchymal stem cells derived from human adipose tissue growing in human blood plasma hydrogels showed a pattern of proliferation similar to that of the cells cultured in monolayer and also maintained their ability to differentiate to osteogenic lineage. Human blood plasma hydrogels are a suitable support for proliferation and osteogenic differentiation of mesenchymal stem cells derived from human adipose tissue and provides a substrate that is autologous, biocompatible, reabsorbable, easy to use, potentially injectable and economic, which could be used as a successful strategy for the management and clinical application of cell therapy in regenerative medicine.

  20. Laser pulse propagation in inhomogeneous magnetoplasma channels and wakefield acceleration

    NASA Astrophysics Data System (ADS)

    Sharma, B. S.; Jain, Archana; Jaiman, N. K.; Gupta, D. N.; Jang, D. G.; Suk, H.; Kulagin, V. V.

    2014-02-01

    Wakefield excitation in a preformed inhomogeneous parabolic plasma channel by an intense relativistic (≃1019 W/cm2) circularly polarized Gaussian laser pulse is investigated analytically and numerically in the presence of an external longitudinal magnetic field. A three dimensional envelope equation for the evolution of the laser pulse is derived, which includes the effect of the nonparaxial and applied external magnetic field. A relation for the channel radius with the laser spot size is derived and examines numerically to see the external magnetic field effect. It is observed that the channel radius depends on the applied external magnetic field. An analytical expression for the wakefield is derived and validated with the help of a two dimensional particle in cell (2D PIC) simulation code. It is shown that the electromagnetic nature of the wakes in an inhomogeneous plasma channel makes their excitation nonlocal, which results in change of fields with time and external magnetic field due to phase mixing of the plasma oscillations with spatially varying frequencies. The magnetic field effect on perturbation of the plasma density and decreasing length is also analyzed numerically. In addition, it has been shown that the electron energy gain in the inhomogeneous parabolic magnetoplasma channel can be increased significantly compared with the homogeneous plasma channel.

  1. Laboratory diagnosis of gestational diabetes: An in silico investigation into the effects of pre-analytical processing on the diagnostic sensitivity and specificity of the oral glucose tolerance test.

    PubMed

    Mansell, Erin; Lunt, Helen; Docherty, Paul

    2017-06-01

    Delayed separation of red cells from plasma causes pre analytical glucose loss, which in turn results in an under-diagnosis of GDM (gestational diabetes) based on the OGTT (oral glucose tolerance test). In silico investigations may help laboratory decision making, when exploring pragmatic improvements to sample processing. Late pregnancy 0, 1 and 2h 75g OGTT values were obtained from two distinct populations of pregnant women: 1. Values derived from the HAPO (Hyperglycemia and Adverse Pregnancy Outcome) Study and 2. New Zealand women identified as at higher risk of GDM by their caregivers, undergoing OGTT during routine antenatal care. In both populations studied, in silico modelling focussed on the effects of pre-analytical delays in plasma separation, when using fluoride collection tubes. Using a model that 'batched' samples from the three OGTT collection times, diagnostic sensitivity was estimated as follows: 66.1% for HAPO research population and 48.4% for the 1305 women receiving routine antenatal care. If samples were not batched, but processed shortly after each blood sample was collected, then sensitivity increased to 81%. Exploration of a range of clinical and laboratory scenarios using in silico modelling, showed that delaying the processing of pregnancy OGTT samples, using batched sample collection into fluoride tubes, causes unacceptable loss of GDM diagnostic sensitivity across two distinct population groups. This modelling approach will hopefully provide information that helps with final decision making around improved laboratory processing techniques. Copyright © 2017 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  2. Maternal and neonatal evaluation of derivated reactive oxygen metabolites (d-ROMs) and biological antioxidant potential in the horse.

    PubMed

    Sgorbini, M; Bonelli, F; Marmorini, P; Biagi, G; Corazza, M; Pasquini, A

    2015-01-01

    The aim of the present work was to evaluate derivated reactive oxygen metabolites (d-ROMs) and biological antioxidant potential (BAP) in mares and foals to study perinatal oxidative status. A total of 60 animals were included in the present study. Maternal and foal venous blood samples were collected immediately after delivery along with a sample drawn from one of the umbilical arteries, and plasma samples were evaluated for lactatemia, d-ROMs, and BAP. The t test for unpaired data was applied between mares versus umbilical artery blood versus foals, both for d-ROMs and BAP. The Pearson test with two-tailed P value and a confidence interval of 95% was performed between d-ROMs and BAP and between d-ROMs and lactatemia, both for mares and foals. Finally, the t test for unpaired data was performed between fillies and colts. The t test showed differences between mares versus their own foals versus umbilical artery blood but not foals versus. umbilical artery blood, both for d-ROMs and BAP. A positive correlation was found both in mares and foals between BAP and d-ROMs and in mares between lactatemia and d-ROM. No differences in gender were found in BAP concentration. Our data are in line to previous studies performed in women and cattle.

  3. Air plasma effect on dental disinfection

    NASA Astrophysics Data System (ADS)

    Duarte, S.; Kuo, S. P.; Murata, R. M.; Chen, C. Y.; Saxena, D.; Huang, K. J.; Popovic, S.

    2011-07-01

    A nonthermal low temperature air plasma jet is characterized and applied to study the plasma effects on oral pathogens and biofilms. Experiments were performed on samples of six defined microorganisms' cultures, including those of gram-positive bacteria and fungi, and on a cultivating biofilm sample of Streptococcus mutans UA159. The results show that the plasma jet creates a zone of microbial growth inhibition in each treated sample; the zone increases with the plasma treatment time and expands beyond the entire region directly exposed to the plasma jet. With 30s plasma treatment twice daily during 5 days of biofilm cultivation, its formation was inhibited. The viability of S. mutans cells in the treated biofilms dropped to below the measurable level and the killed bacterial cells concentrated to local regions as manifested by the fluorescence microscopy via the environmental scanning electron microscope. The emission spectroscopy of the jet indicates that its plasma effluent carries an abundance of reactive atomic oxygen, providing catalyst for the observed plasma effect.

  4. Air plasma effect on dental disinfection

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Duarte, S.; Murata, R. M.; Saxena, D.

    2011-07-15

    A nonthermal low temperature air plasma jet is characterized and applied to study the plasma effects on oral pathogens and biofilms. Experiments were performed on samples of six defined microorganisms' cultures, including those of gram-positive bacteria and fungi, and on a cultivating biofilm sample of Streptococcus mutans UA159. The results show that the plasma jet creates a zone of microbial growth inhibition in each treated sample; the zone increases with the plasma treatment time and expands beyond the entire region directly exposed to the plasma jet. With 30s plasma treatment twice daily during 5 days of biofilm cultivation, its formationmore » was inhibited. The viability of S. mutans cells in the treated biofilms dropped to below the measurable level and the killed bacterial cells concentrated to local regions as manifested by the fluorescence microscopy via the environmental scanning electron microscope. The emission spectroscopy of the jet indicates that its plasma effluent carries an abundance of reactive atomic oxygen, providing catalyst for the observed plasma effect.« less

  5. A new (2+1) dimensional integrable evolution equation for an ion acoustic wave in a magnetized plasma

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mukherjee, Abhik, E-mail: abhik.mukherjee@saha.ac.in; Janaki, M. S., E-mail: ms.janaki@saha.ac.in; Kundu, Anjan, E-mail: anjan.kundu@saha.ac.in

    2015-07-15

    A new, completely integrable, two dimensional evolution equation is derived for an ion acoustic wave propagating in a magnetized, collisionless plasma. The equation is a multidimensional generalization of a modulated wavepacket with weak transverse propagation, which has resemblance to nonlinear Schrödinger (NLS) equation and has a connection to Kadomtsev-Petviashvili equation through a constraint relation. Higher soliton solutions of the equation are derived through Hirota bilinearization procedure, and an exact lump solution is calculated exhibiting 2D structure. Some mathematical properties demonstrating the completely integrable nature of this equation are described. Modulational instability using nonlinear frequency correction is derived, and the correspondingmore » growth rate is calculated, which shows the directional asymmetry of the system. The discovery of this novel (2+1) dimensional integrable NLS type equation for a magnetized plasma should pave a new direction of research in the field.« less

  6. Resistive magnetohydrodynamics with toroidal rotation in toroidal plasmas

    NASA Astrophysics Data System (ADS)

    Cao, Jintao; Cai, Huishan

    2018-01-01

    Toroidal rotation has always existed in tokamak plasmas, and its Mach number can reach unity during neutral beam injection. Toroidal rotation can affect plasma equilibrium and magnetohydrodynamic instabilities significantly. Based on linearized equations including the toroidal rotation effect, the toroidal model derived by Glasser et al. [Phys. Fluids 18, 875 (1975)] is extended to include this effect, and a set of resistive equations including the toroidal rotation effect in the axi-symmetry toroidal geometry is derived. Based on these derived equations, the effect of toroidal rotation on tearing modes is considered, and the growth rate of tearing modes is obtained analytically. It is shown that the effect of toroidal rotation on tearing modes depends on both the direction of toroidal rotation flow and the sign of toroidal rotation flow shear. When they have the same sign, they play a role in stabilizing tearing modes, while when they have opposite signs, they have a destabilizing effect on tearing modes.

  7. Pro-resolving lipid mediator Resolvin D1 serves as a marker of lung disease in cystic fibrosis.

    PubMed

    Eickmeier, Olaf; Fussbroich, Daniela; Mueller, Klaus; Serve, Friederike; Smaczny, Christina; Zielen, Stefan; Schubert, Ralf

    2017-01-01

    Cystic fibrosis (CF) is an autosomal recessive genetic disorder that affects multiple organs, including the lungs, pancreas, liver and intestine. Mutations in the cystic fibrosis transmembrane conductance regulator (CFTR) locus lead to defective proteins and reduced Cl- secretion and Na+ hyperabsorption in the affected organs. In addition, patients suffering from CF display chronic inflammation that contributes to the pathogenesis of CF. Recent work suggests that CF patients have a reduced capacity to biosynthesize specialized pro-resolving lipid mediators (SPMs), which contributes to the development and duration of the unwanted inflammation. Alterations in the metabolism of arachidonic acid (AA) and docosahexaenoic acid (DHA) to specialized pro-resolving mediators (SPMs), like lipoxins (LXs), maresins (MaRs), protectins (PDs) and resolvins (Rvs), may play a major role on clinical impact of airway inflammation in CF. In this study, our aims were to detect and quantitate Resolvin D1 (RvD1) in sputum and plasma from patients with CF and compare levels of RvD1 with biomarkers of inflammation and lung function. We studied 27 CF patients aged 6 to 55 years (median 16 years) in a prospective approach. DHA can be found in the plasma of our CF patients in the milligram range and is decreased in comparison to a healthy control group. The DHA-derived pro-resolving mediator Resolvin D1 (RvD1) was also present in the plasma (286.4 ± 50 pg/ mL, mean ± SEM) and sputum (30.0 ± 2.6 pg/ mL, mean ± SEM) samples from our patients with CF and showed a positive correlation with sputum inflammatory markers. The plasma concentrations of RvD1 were ten times higher than sputum concentrations. Interestingly, sputum RvD1/ IL-8 levels showed a positive correlation with FEV1 (rs = 0.3962, p< 0.05). SPMs, like RvD1, are well known to down-regulate inflammatory pathways. Our study shows that the bioactive lipid mediator RvD1, derived from DHA, was present in sputum and plasma of CF patients and may serve as a representative peripheral biomarker of the lung resolution program for CF patients.

  8. Opioid Concentrations in Oral Fluid and Plasma in Cancer Patients With Pain.

    PubMed

    Heiskanen, Tarja; Langel, Kaarina; Gunnar, Teemu; Lillsunde, Pirjo; Kalso, Eija A

    2015-10-01

    Measuring opioid concentrations in pain treatment is warranted in situations where optimal opioid analgesia is difficult to reach. To assess the usefulness of oral fluid (OFL) as an alternative to plasma in opioid concentration monitoring in cancer patients on chronic opioid therapy. We collected OFL and plasma samples from 64 cancer patients on controlled-release (CR) oral morphine, CR oral oxycodone, or transdermal (TD) fentanyl for pain. Samples were obtained on up to five separate days. A total of 213 OFL and plasma samples were evaluable. All patients had detectable amounts of the CR or TD opioid in both plasma and OFL samples. The plasma concentrations of oxycodone and fentanyl (determination coefficient R(2) = 0.628 and 0.700, respectively), but not morphine (R(2) = 0.292), were moderately well correlated to the daily opioid doses. In contrast to morphine and fentanyl (mean OFL/plasma ratio 2.0 and 3.0, respectively), the OFL oxycodone concentrations were significantly higher than the respective plasma concentrations (mean OFL/plasma ratio 14.9). An active transporter could explain the much higher OFL vs. plasma concentrations of oxycodone compared with morphine and fentanyl. OFL analysis is well suited for detecting the studied opioids. For morphine and fentanyl, an approximation of the plasma opioid concentrations is obtainable, whereas for oxycodone, the OFL/plasma concentration relationship is too variable for reliable approximation results. Copyright © 2015 American Academy of Hospice and Palliative Medicine. Published by Elsevier Inc. All rights reserved.

  9. Thrust and efficiency model for electron-driven magnetic nozzles

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Little, Justin M.; Choueiri, Edgar Y.

    2013-10-15

    A performance model is presented for magnetic nozzle plasmas driven by electron thermal expansion to investigate how the thrust coefficient and beam divergence efficiency scale with the incoming plasma flow and magnetic field geometry. Using a transformation from cylindrical to magnetic coordinates, an approximate analytical solution is derived to the axisymmetric two-fluid equations for a collisionless plasma flow along an applied magnetic field. This solution yields an expression for the half-width at half-maximum of the plasma density profile in the far-downstream region, from which simple scaling relations for the thrust coefficient and beam divergence efficiency are derived. It is foundmore » that the beam divergence efficiency is most sensitive to the density profile of the flow into the nozzle throat, with the highest efficiencies occurring for plasmas concentrated along the nozzle axis. Increasing the expansion ratio of the magnetic field leads to efficiency improvements that are more pronounced for incoming plasmas that are not concentrated along the axis. This implies that the additional magnet required to increase the expansion ratio may be worth the added complexity for plasma sources that exhibit poor confinement.« less

  10. 21 CFR 640.80 - Albumin (Human).

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... a sterile solution of the albumin derived from human plasma. (b) Source material. The source material of Albumin (Human) shall be plasma recovered from Whole Blood prepared as prescribed in §§ 640.1 through 640.5, or Source Plasma prepared as prescribed in §§ 640.60 through 640.76. (c) Additives in...

  11. 21 CFR 640.80 - Albumin (Human).

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... a sterile solution of the albumin derived from human plasma. (b) Source material. The source material of Albumin (Human) shall be plasma recovered from Whole Blood prepared as prescribed in §§ 640.1 through 640.5, or Source Plasma prepared as prescribed in §§ 640.60 through 640.76. (c) Additives in...

  12. 21 CFR 640.80 - Albumin (Human).

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... a sterile solution of the albumin derived from human plasma. (b) Source material. The source material of Albumin (Human) shall be plasma recovered from Whole Blood prepared as prescribed in §§ 640.1 through 640.5, or Source Plasma prepared as prescribed in §§ 640.60 through 640.76. (c) Additives in...

  13. 21 CFR 640.80 - Albumin (Human).

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... a sterile solution of the albumin derived from human plasma. (b) Source material. The source material of Albumin (Human) shall be plasma recovered from Whole Blood prepared as prescribed in §§ 640.1 through 640.5, or Source Plasma prepared as prescribed in §§ 640.60 through 640.76. (c) Additives in...

  14. 21 CFR 640.80 - Albumin (Human).

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... a sterile solution of the albumin derived from human plasma. (b) Source material. The source material of Albumin (Human) shall be plasma recovered from Whole Blood prepared as prescribed in §§ 640.1 through 640.5, or Source Plasma prepared as prescribed in §§ 640.60 through 640.76. (c) Additives in...

  15. Selective binding to transthyretin and tetramer stabilization in serum from patients with familial amyloidotic polyneuropathy by an iodinated diflunisal derivative

    PubMed Central

    2004-01-01

    In familial amyloidotic polyneuropathy, TTR (transthyretin) variants are deposited as amyloid fibrils. It is thought that this process involves TTR tetramer dissociation, which leads to partially unfolded monomers that aggregate and polymerize into amyloid fibrils. This process can be counteracted by stabilization of the tetramer. Several small compounds, such as diclofenac, diflunisal and flufenamic acid, have been reported to bind to TTR in vitro, in the T4 (thyroxine) binding channel that runs through the TTR tetramer, and consequently are considered to stabilize TTR. However, if these agents bind plasma proteins other than TTR, decreased drug availability will occur, compromising their use as therapeutic agents for TTR amyloidosis. In the present work, we compared the action of these compounds and of new derivatives designed to increase both selectivity of binding to TTR and inhibitory potency in relation to TTR amyloid fibril formation. We found two diflunisal derivatives that, in contrast with diclofenac, flufenamic acid and diflunisal, displaced T4 from TTR in plasma preferentially over binding to albumin and thyroxine binding globulin. The same diflunisal derivatives also had a stabilizing effect on TTR tetramers in plasma, as studied by isoelectric focusing of whole plasma under semi-denaturing conditions. In addition, by transmission electron microscopy, we demonstrated that, in contrast with other proposed TTR stabilizers (namely diclofenac, flufenamic acid and diflunisal), one of the diflunisal derivatives tested efficiently inhibited TTR aggregation. Taken together, our ex vivo and in vitro studies present evidence for the selectivity and efficiency of novel diflunisal derivates as TTR stabilizers and as inhibitors of fibril formation. PMID:15080795

  16. Intestinal ABCA1 directly contributes to HDL biogenesis in vivo

    PubMed Central

    Brunham, Liam R.; Kruit, Janine K.; Iqbal, Jahangir; Fievet, Catherine; Timmins, Jenelle M.; Pape, Terry D.; Coburn, Bryan A.; Bissada, Nagat; Staels, Bart; Groen, Albert K.; Hussain, M. Mahmood; Parks, John S.; Kuipers, Folkert; Hayden, Michael R.

    2006-01-01

    Plasma HDL cholesterol levels are inversely related to risk for atherosclerosis. The ATP-binding cassette, subfamily A, member 1 (ABCA1) mediates the rate-controlling step in HDL particle formation, the assembly of free cholesterol and phospholipids with apoA-I. ABCA1 is expressed in many tissues; however, the physiological functions of ABCA1 in specific tissues and organs are still elusive. The liver is known to be the major source of plasma HDL, but it is likely that there are other important sites of HDL biogenesis. To assess the contribution of intestinal ABCA1 to plasma HDL levels in vivo, we generated mice that specifically lack ABCA1 in the intestine. Our results indicate that approximately 30% of the steady-state plasma HDL pool is contributed by intestinal ABCA1 in mice. In addition, our data suggest that HDL derived from intestinal ABCA1 is secreted directly into the circulation and that HDL in lymph is predominantly derived from the plasma compartment. These data establish a critical role for intestinal ABCA1 in plasma HDL biogenesis in vivo. PMID:16543947

  17. Myeloperoxidase-derived 2-chlorofatty acids contribute to human sepsis mortality via acute respiratory distress syndrome.

    PubMed

    Meyer, Nuala J; Reilly, John P; Feng, Rui; Christie, Jason D; Hazen, Stanley L; Albert, Carolyn J; Franke, Jacob D; Hartman, Celine L; McHowat, Jane; Ford, David A

    2017-12-07

    Sepsis-associated acute respiratory distress syndrome (ARDS) is characterized by neutrophilic inflammation and poor survival. Since neutrophil myeloperoxidase (MPO) activity leads to increased plasma 2-chlorofatty acid (2-ClFA) levels, we hypothesized that plasma concentrations of 2-ClFAs would associate with ARDS and mortality in subjects with sepsis. In sequential consenting patients with sepsis, free 2-ClFA levels were significantly associated with ARDS, and with 30-day mortality, for each log increase in free 2-chlorostearic acid. Plasma MPO was not associated with either ARDS or 30-day mortality but was correlated with 2-ClFA levels. Addition of plasma 2-ClFA levels to the APACHE III score improved prediction for ARDS. Plasma 2-ClFA levels correlated with plasma levels of angiopoietin-2, E selectin, and soluble thrombomodulin. Endothelial cells treated with 2-ClFA responded with increased adhesion molecule surface expression, increased angiopoietin-2 release, and dose-dependent endothelial permeability. Our results suggest that 2-ClFAs derived from neutrophil MPO-catalyzed oxidation contribute to pulmonary endothelial injury and have prognostic utility in sepsis-associated ARDS.

  18. Magnetosonic cnoidal waves and solitons in a magnetized dusty plasma

    NASA Astrophysics Data System (ADS)

    Kaur, Nimardeep; Singh, Manpreet; Saini, N. S.

    2018-04-01

    An investigation of magnetosonic nonlinear periodic (cnoidal) waves is presented in a magnetized electron-ion-dust ( e -i -d ) plasma having cold dust fluid with inertialess warm ions and electrons. The reductive perturbation method is employed to derive the Korteweg-de Vries equation. The dispersion relation for magnetosonic cnoidal waves is determined in the linear limit. The magnetosonic cnoidal wave solution is derived using the Sagdeev pseudopotential approach under the specific boundary conditions. There is the formation of only positive potential magnetosonic cnoidal waves and solitary structures in the high plasma-β limit. The effects of various plasma parameters, viz., plasma beta (β), σ (temperature ratio of electrons to ions), and μd (ratio of the number density of dust to electrons) on the characteristics of magnetosonic cnoidal waves are also studied numerically. The findings of the present investigation may be helpful in describing the characteristics of various nonlinear excitations in Earth's magnetosphere, solar wind, Saturn's magnetosphere, and space/astrophysical environments, where many space observations by various satellites confirm the existence of dust grains, highly energetic electrons, and high plasma-β.

  19. Protective effects of coffee-derived compounds on lipopolysaccharide/D-galactosamine induced acute liver injury in rats.

    PubMed

    Akashi, Iwao; Kagami, Keisuke; Hirano, Toshihiko; Oka, Kitaro

    2009-04-01

    The protective effects of coffee-derived compounds on lipopolysaccharide/D-galactosamine (LPS/D-GalN) induced acute liver injury in rats were investigated. Wistar rats were orally administered saline (control) or one of the test compounds (caffeine, chlorogenic acid, trigonelline, nicotinic acid or eight pyrazinoic acids) at a dose of 100 mg/kg, respectively. This was followed by intraperitoneal injection with LPS (100 mug/kg)/D-GalN (250 mg/kg) 1 h after administration of the test compounds. Blood samples were collected up to 12 h after LPS/D-GalN injection, followed by determination of plasma aspartate aminotransferase, alanine aminotransferase, tumour necrosis factor alpha (TNF-alpha) and interleukin 10 (IL-10) levels. Plasma aspartate aminotransferase and alanine aminotransferase levels were significantly increased after LPS/D-GalN-treatment, but were suppressed by pretreatment with caffeine (n = 5), nicotinic acid, non-substituted pyrazinoic acid or 5-methylpyrazinoic acid (n = 6, respectively) 12 h after LPS/D-GalN-treatment (P < 0.01, respectively). Moreover, the animals pretreated with these test compounds showed significantly higher survival rates (83-100%) compared with the control (23%). Only pretreatment with caffeine significantly suppressed the LPS/D-GalN induced elevation of plasma TNF-alpha levels 1 and 2 h after LPS/D-GalN-treatment (P < 0.01, respectively). Pretreatment with caffeine, nicotinic acid or non-substituted pyrazinoic acid activated the LPS/D-GalN induced elevation of plasma IL-10 levels at 1 and 2 h, although there were no statistically significant differences in IL-10 levels between control and nicotinic acid or non-substituted pyrazinoic acid treated rats. The results suggest that caffeine, nicotinic acid, non-substituted pyrazinoic acid and 5-methylpyrazinoic acid can protect against LPS/D-GalN induced acute liver injury, which may be mediated by the reduction of TNF-alpha production and/or increasing IL-10 production.

  20. Avian plasma chemistry analysis using diluted samples.

    PubMed

    Waldoch, Jennifer; Wack, Raymund; Christopher, Mary

    2009-12-01

    Clinical chemistry tests are essential for the diagnosis and monitoring of disease in birds. The small volume of blood that can be obtained from many avian species limits the use of routine in-house chemistry analyzers. The aim of this study was to examine the accuracy and precision of avian plasma chemistry values obtained by use of a benchtop analyzer in samples diluted with sterile water, as compared with undiluted samples. Whole blood samples were collected from 13 clinically healthy thick-billed parrots (Rhynchopsitta pachyrhyncha). The samples were placed in lithium heparin tubes and centrifuged and the plasma decanted. One aliquot was analyzed immediately using a VetScan benchtop analyzer with an avian-reptile-specific rotor that included 12 analytes. The remainder of the plasma was divided into two aliquots and stored at -80 degrees C until analysis. One of these aliquots was diluted 1:1, 1:1.5, 1:2, and 1:2.5 with sterile water to give final dilutions of 1:2, 1:2.5, 1:3, and 1:3.5, respectively. The other aliquot was pooled with the 12 other samples to create a plasma pool. The undiluted plasma pool and two final dilutions (1:2 and 1:3) of the pooled plasma were analyzed in replicate (n = 20) to determine intra- and interassay imprecision. Each dilution was analyzed using the avian-reptile rotor and the results multiplied by the appropriate dilution factor to obtain the final result. Significant differences were observed in clinical chemistry results obtained from diluted plasma samples for all analytes except aspartate aminotransferase, creatine kinase, and glucose. Uric acid concentration was not significantly different at dilutions of up to 1:3. Bile acids, globulins, and sodium concentrations were below the limit of detection in all diluted samples and were not statistically analyzed. Based on these results, dilution with sterile water is not recommended for biochemical analysis of avian plasma using the VetScan benchtop analyzer.

Top