Sample records for plasma samples obtained

  1. Systematic Evaluation of the Use of Human Plasma and Serum for Mass-Spectrometry-Based Shotgun Proteomics.

    PubMed

    Lan, Jiayi; Núñez Galindo, Antonio; Doecke, James; Fowler, Christopher; Martins, Ralph N; Rainey-Smith, Stephanie R; Cominetti, Ornella; Dayon, Loïc

    2018-04-06

    Over the last two decades, EDTA-plasma has been used as the preferred sample matrix for human blood proteomic profiling. Serum has also been employed widely. Only a few studies have assessed the difference and relevance of the proteome profiles obtained from plasma samples, such as EDTA-plasma or lithium-heparin-plasma, and serum. A more complete evaluation of the use of EDTA-plasma, heparin-plasma, and serum would greatly expand the comprehensiveness of shotgun proteomics of blood samples. In this study, we evaluated the use of heparin-plasma with respect to EDTA-plasma and serum to profile blood proteomes using a scalable automated proteomic pipeline (ASAP 2 ). The use of plasma and serum for mass-spectrometry-based shotgun proteomics was first tested with commercial pooled samples. The proteome coverage consistency and the quantitative performance were compared. Furthermore, protein measurements in EDTA-plasma and heparin-plasma samples were comparatively studied using matched sample pairs from 20 individuals from the Australian Imaging, Biomarkers and Lifestyle (AIBL) Study. We identified 442 proteins in common between EDTA-plasma and heparin-plasma samples. Overall agreement of the relative protein quantification between the sample pairs demonstrated that shotgun proteomics using workflows such as the ASAP 2 is suitable in analyzing heparin-plasma and that such sample type may be considered in large-scale clinical research studies. Moreover, the partial proteome coverage overlaps (e.g., ∼70%) showed that measures from heparin-plasma could be complementary to those obtained from EDTA-plasma.

  2. Avian plasma chemistry analysis using diluted samples.

    PubMed

    Waldoch, Jennifer; Wack, Raymund; Christopher, Mary

    2009-12-01

    Clinical chemistry tests are essential for the diagnosis and monitoring of disease in birds. The small volume of blood that can be obtained from many avian species limits the use of routine in-house chemistry analyzers. The aim of this study was to examine the accuracy and precision of avian plasma chemistry values obtained by use of a benchtop analyzer in samples diluted with sterile water, as compared with undiluted samples. Whole blood samples were collected from 13 clinically healthy thick-billed parrots (Rhynchopsitta pachyrhyncha). The samples were placed in lithium heparin tubes and centrifuged and the plasma decanted. One aliquot was analyzed immediately using a VetScan benchtop analyzer with an avian-reptile-specific rotor that included 12 analytes. The remainder of the plasma was divided into two aliquots and stored at -80 degrees C until analysis. One of these aliquots was diluted 1:1, 1:1.5, 1:2, and 1:2.5 with sterile water to give final dilutions of 1:2, 1:2.5, 1:3, and 1:3.5, respectively. The other aliquot was pooled with the 12 other samples to create a plasma pool. The undiluted plasma pool and two final dilutions (1:2 and 1:3) of the pooled plasma were analyzed in replicate (n = 20) to determine intra- and interassay imprecision. Each dilution was analyzed using the avian-reptile rotor and the results multiplied by the appropriate dilution factor to obtain the final result. Significant differences were observed in clinical chemistry results obtained from diluted plasma samples for all analytes except aspartate aminotransferase, creatine kinase, and glucose. Uric acid concentration was not significantly different at dilutions of up to 1:3. Bile acids, globulins, and sodium concentrations were below the limit of detection in all diluted samples and were not statistically analyzed. Based on these results, dilution with sterile water is not recommended for biochemical analysis of avian plasma using the VetScan benchtop analyzer.

  3. Method of high-precision microsampled blood and plasma mass densitometry

    NASA Technical Reports Server (NTRS)

    Hinghofer-Szalkay, H.

    1986-01-01

    The reliability of the mechanical oscillator technique for blood and plasma density measurements on samples of volumes less than 0.1 ml is examined, and a precision of 0.001 g/l is found if plasma-isodensic heparin solution and siliconized densitometers are employed. Sources of measurement errors in the density determinations include storage of plasma samples, inhomogeneity of blood samples, and density reading before adequate temperature equilibration. In tests of plasma sample storage, the best reproducibility was obtained with samples kept at 4 C. Linear correlations were found between plasma density and plasma protein concentration, blood density and blood hemoglobin concentration, and erythrocyte density and MCHC.

  4. Plasma and Serum Metabolite Association Networks: Comparability within and between Studies Using NMR and MS Profiling.

    PubMed

    Suarez-Diez, Maria; Adam, Jonathan; Adamski, Jerzy; Chasapi, Styliani A; Luchinat, Claudio; Peters, Annette; Prehn, Cornelia; Santucci, Claudio; Spyridonidis, Alexandros; Spyroulias, Georgios A; Tenori, Leonardo; Wang-Sattler, Rui; Saccenti, Edoardo

    2017-07-07

    Blood is one of the most used biofluids in metabolomics studies, and the serum and plasma fractions are routinely used as a proxy for blood itself. Here we investigated the association networks of an array of 29 metabolites identified and quantified via NMR in the plasma and serum samples of two cohorts of ∼1000 healthy blood donors each. A second study of 377 individuals was used to extract plasma and serum samples from the same individual on which a set of 122 metabolites were detected and quantified using FIA-MS/MS. Four different inference algorithms (ARANCE, CLR, CORR, and PCLRC) were used to obtain consensus networks. The plasma and serum networks obtained from different studies showed different topological properties with the serum network being more connected than the plasma network. On a global level, metabolite association networks from plasma and serum fractions obtained from the same blood sample of healthy people show similar topologies, and at a local level, some differences arise like in the case of amino acids.

  5. Plasma and Serum Metabolite Association Networks: Comparability within and between Studies Using NMR and MS Profiling

    PubMed Central

    2017-01-01

    Blood is one of the most used biofluids in metabolomics studies, and the serum and plasma fractions are routinely used as a proxy for blood itself. Here we investigated the association networks of an array of 29 metabolites identified and quantified via NMR in the plasma and serum samples of two cohorts of ∼1000 healthy blood donors each. A second study of 377 individuals was used to extract plasma and serum samples from the same individual on which a set of 122 metabolites were detected and quantified using FIA–MS/MS. Four different inference algorithms (ARANCE, CLR, CORR, and PCLRC) were used to obtain consensus networks. The plasma and serum networks obtained from different studies showed different topological properties with the serum network being more connected than the plasma network. On a global level, metabolite association networks from plasma and serum fractions obtained from the same blood sample of healthy people show similar topologies, and at a local level, some differences arise like in the case of amino acids. PMID:28517934

  6. Use of vitamin B12 in joint lavage for determination of dilution factors of canine synovial fluid.

    PubMed

    de Bruin, Tanya; de Rooster, Hilde; van Bree, Henri; Cox, Eric

    2005-11-01

    To test a modified saline (0.9% NaCl) solution joint washing (lavage) technique that includes the use of vitamin B12 as an internal marker for the evaluation of synovial fluid dilution in lavage samples from canine joints. 9 plasma samples obtained from blood samples of 9 healthy dogs and 9 synovial fluid samples aspirated from stifle joints of 9 cadaveric dogs. Photometric absorbances of 25% vitamin B12 solution, canine synovial fluid, and canine plasma were measured in a spectrophotometer to establish an optimal wavelength for analysis. Canine synovial fluid and plasma samples were mixed with the 25% vitamin B12 solution to obtain 1%, 3%, 5%, 10%, 20%, and 50% solutions of synovial fluid or plasma. Diluted synovial fluid and plasma samples were used to simulate joint lavage samples and to examine the possible interference of these substances (synovial fluid or plasma) with the absorbance of the 25% vitamin B12 solution in photometric analysis. The optimal wavelength was found to be at 550 nm. Canine synovial fluid and plasma samples did not interfere with the absorbance measurements of the 25% vitamin B12 solution up to a 50% dilution of plasma or synovial fluid. The modified saline solution joint lavage method with the use of a 25% vitamin B12 solution as an internal standard provides an accurate and reliable technique for the evaluation of synovial fluid dilution in lavage samples from canine joints.

  7. Liquid chromatography tandem-mass spectrometry (LC-MS/MS) and dried blood spot sampling applied to pharmacokinetics studies in animals: Correlation of classic and block design.

    PubMed

    Baldo, Matías N; Angeli, Emmanuel; Gareis, Natalia C; Hunzicker, Gabriel A; Murguía, Marcelo C; Ortega, Hugo H; Hein, Gustavo J

    2018-04-01

    A relative bioavailability study (RBA) of two phenytoin (PHT) formulations was conducted in rabbits, in order to compare the results obtained from different matrices (plasma and blood from dried blood spot (DBS) sampling) and different experimental designs (classic and block). The method was developed by liquid chromatography tandem-mass spectrometry (LC-MS/MS) in plasma and blood samples. The different sample preparation techniques, plasma protein precipitation and DBS, were validated according to international requirements. The analytical method was validated with ranges 0.20-50.80 and 0.12-20.32 µg ml -1 , r > 0.999 for plasma and blood, respectively. Accuracy and precision were within acceptance criteria for bioanalytical assay validation (< 15 for bias and CV% and < 20 for limit of quantification (LOQ)). PHT showed long-term stability, both for plasma and blood, and under refrigerated and room temperature conditions. Haematocrit values were measured during the validation process and RBA study. Finally, the pharmacokinetic parameters (C max , T max and AUC 0-t ) obtained from the RBA study were tested. Results were highly comparable for matrices and experimental designs. A matrix correlation higher than 0.975 and a ratio of (PHT blood) = 1.158 (PHT plasma) were obtained. The results obtained herein show that the use of classic experimental design and DBS sampling for animal pharmacokinetic studies should be encouraged as they could help to prevent the use of a large number of animals and also animal euthanasia. Finally, the combination of DBS sampling with LC-MS/MS technology showed to be an excellent tool not only for therapeutic drug monitoring but also for RBA studies.

  8. Salivary caffeine concentrations are comparable to plasma concentrations in preterm infants receiving extended caffeine therapy

    PubMed Central

    Liu, Xiaoxi; Rhein, Lawrence M.; Darnall, Robert A.; Corwin, Michael J.; McEntire, Betty L.; Ward, Robert M.; James, Laura P.; Sherwin, Catherine M. T.; Heeren, Timothy C.; Hunt, Carl E.

    2016-01-01

    Aims Caffeine concentrations in preterm infants are usually measured in the blood. However, salivary assays may provide a valid and practical alternative. The present study explored the validity and clinical utility of salivary caffeine concentrations as an alternative to blood concentrations and developed a novel plasma/salivary caffeine distribution model. Methods Paired salivary and plasma samples were obtained in 29 infants. Salivary samples were obtained using a commercially available salivary collection system. Caffeine concentrations in the saliva and plasma were determined using high‐performance liquid chromatography. A population pharmacokinetic (PK) model was developed using NONMEM 7.3. Results The mean (± standard deviation) gestational age (GA) at birth and birth weight were 27.9 ± 2.1 weeks and 1171.6 ± 384.9 g, respectively. Paired samples were obtained at a mean postmenstrual age (PMA) of 35.5 ± 1.1 weeks. The range of plasma caffeine concentrations was 9.5–54.1 μg ml−1, with a mean difference (95% confidence interval) between plasma and salivary concentrations of −0.18 μg ml−1 (−1.90, 1.54). Salivary and plasma caffeine concentrations were strongly correlated (Pearson's correlation coefficient = 0.87, P < 0.001). Caffeine PK in plasma and saliva was simultaneously described by a three‐compartment recirculation model. Current body weight, birth weight, GA, PMA and postnatal age were not significantly correlated with any PK parameter. Conclusions Salivary sampling provides an easy, non‐invasive method for measuring caffeine concentrations. Salivary concentrations correlate highly with plasma concentrations. Caffeine PK in saliva and plasma are well described by a three‐compartment recirculation model. PMID:27145974

  9. Measurement of tritium with plastic scintillator surface improvement with plasma treatment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yoshihara, Y.; Furuta, E.; Ohyama, R.I.

    2015-03-15

    Tritium is usually measured by using a liquid scintillation counter. However, liquid scintillator used for measurement will become radioactive waste fluid. To solve this issue, we have developed a method of measuring tritium samples with plasma-treated plastic scintillator (PS)sheets (Plasma method). The radioactive sample is held between 2 PS sheets and the whole is enclosed in a a low-potassium glass vial. With the Plasma method of 2-min plasma treatment, we have obtained measurement efficiency of 48 ± 2 % for 2 min measurement of tritium except for tritiated water. The plasma treatment makes the PS surface rough and hydrophilic whichmore » contributes to improve the contact between tritium and PS. On the other hand, it needed almost 6 hours to obtain constant measurement efficiency. The reason was that the dry-up handling in the vial needed longer time to vaporize H{sub 2}O molecules than in the air. We tried putting silica gel beads into vials to remove H{sub 2}O molecules from PS sheet surface quickly. The silica gel beads worked well and we got constant measurement efficiency within 1-3 hours. Also, we tried using other kinds of PS treated with plasma to obtain higher measurement efficiencies of tritium samples.« less

  10. Opioid Concentrations in Oral Fluid and Plasma in Cancer Patients With Pain.

    PubMed

    Heiskanen, Tarja; Langel, Kaarina; Gunnar, Teemu; Lillsunde, Pirjo; Kalso, Eija A

    2015-10-01

    Measuring opioid concentrations in pain treatment is warranted in situations where optimal opioid analgesia is difficult to reach. To assess the usefulness of oral fluid (OFL) as an alternative to plasma in opioid concentration monitoring in cancer patients on chronic opioid therapy. We collected OFL and plasma samples from 64 cancer patients on controlled-release (CR) oral morphine, CR oral oxycodone, or transdermal (TD) fentanyl for pain. Samples were obtained on up to five separate days. A total of 213 OFL and plasma samples were evaluable. All patients had detectable amounts of the CR or TD opioid in both plasma and OFL samples. The plasma concentrations of oxycodone and fentanyl (determination coefficient R(2) = 0.628 and 0.700, respectively), but not morphine (R(2) = 0.292), were moderately well correlated to the daily opioid doses. In contrast to morphine and fentanyl (mean OFL/plasma ratio 2.0 and 3.0, respectively), the OFL oxycodone concentrations were significantly higher than the respective plasma concentrations (mean OFL/plasma ratio 14.9). An active transporter could explain the much higher OFL vs. plasma concentrations of oxycodone compared with morphine and fentanyl. OFL analysis is well suited for detecting the studied opioids. For morphine and fentanyl, an approximation of the plasma opioid concentrations is obtainable, whereas for oxycodone, the OFL/plasma concentration relationship is too variable for reliable approximation results. Copyright © 2015 American Academy of Hospice and Palliative Medicine. Published by Elsevier Inc. All rights reserved.

  11. Sensitivity and Specificity of an Operon Immunochromatographic Test in Serum and Whole-Blood Samples for the Diagnosis of Trypanosoma cruzi Infection in Spain, an Area of Nonendemicity

    PubMed Central

    Flores-Chavez, María; Cruz, Israel; Nieto, Javier; Gárate, Teresa; Navarro, Miriam; Pérez-Ayala, Ana; López-Vélez, Rogelio

    2012-01-01

    Trypanosoma cruzi infection is an imported parasitic disease in Spain, and the majority of infected individuals are in the chronic phase of the disease. This study evaluated the sensitivity and specificity of the Operon immunochromatographic test (ICT-Operon; Simple Stick Chagas and Simple Chagas WB [whole blood]; Operon S.A., Spain) for different biological samples. Well-characterized serum samples were obtained from chagasic patients (n = 63), nonchagasic individuals (n = 95), visceral leishmaniasis patients (n = 38), and malaria patients (n = 55). Noncharacterized specimens were obtained from Latin American immigrants and individuals at risk with a clinical and/or epidemiological background: these specimens were recovered serum or plasma samples (n = 450), whole peripheral blood (n = 94), and capillary blood (n = 282). The concordance of the results by enzyme-linked immunosorbent assay and indirect immunofluorescence test was considered to be the “gold standard” for diagnosis. Serum and plasma samples were analyzed by Stick Chagas, and whole blood was analyzed by Simple Chagas WB. The sensitivity and specificity of the ICT-Operon in well-characterized samples were 100% and 97.9%, respectively. No cross-reactivity was found with samples obtained from visceral leishmaniasis patients. In contrast, a false-positive result was obtained in 27.3% of samples from malaria patients. The sensitivities of the rapid test in noncharacterized serum or plasma, peripheral blood, and capillary blood samples were 100%, 92.1%, and 86.4%, respectively, while the specificities were 91.6%, 93.6%, and 95% in each case. ICT-Operon showed variable sensitivity, depending on the kind of sample, performing better when serum or plasma samples were used. It could therefore be used for serological screening combined with any other conventional test. PMID:22761296

  12. Developing New Epidemiologic Tools for Investigating Breast Cancer Risk

    DTIC Science & Technology

    1997-09-01

    EGF and TGF- a levels to each other and to plasma levels of estradiol and progesterone. Breast fluid and plasma samples were obtained two to four...relationships between EGF and TGF- a levels or between either GF level and menstrual cycle phase or plasma hormone concentrations. However, in random...and TGF- a levels were related to the menstrual cycle phase, to plasma estradiol or progesterone levels, or to each other. By repeat sampling of

  13. An Example of Genetically Distinct HIV Type 1 Variants in Cerebrospinal Fluid and Plasma During Suppressive Therapy

    PubMed Central

    Dahl, Viktor; Gisslen, Magnus; Hagberg, Lars; Peterson, Julia; Shao, Wei; Spudich, Serena; Price, Richard W.; Palmer, Sarah

    2014-01-01

    We sequenced the genome of human immunodeficiency virus type 1 (HIV-1) recovered from 70 cerebrospinal fluid (CSF) specimens and 29 plasma samples and corresponding samples obtained before treatment initiation from 17 subjects receiving suppressive therapy. More CSF sequences than plasma sequences were hypermutants. We determined CSF sequences and plasma sequences in specimens obtained from 2 subjects after treatment initiation. In one subject, we found genetically distinct CSF and plasma sequences, indicating that they came from HIV-1 from 2 different compartments, one potentially the central nervous system, during suppressive therapy. In addition, there was little evidence of viral evolution in the CSF during therapy, suggesting that continuous virus replication is not the major cause of viral persistence in the central nervous system. PMID:24338353

  14. An example of genetically distinct HIV type 1 variants in cerebrospinal fluid and plasma during suppressive therapy.

    PubMed

    Dahl, Viktor; Gisslen, Magnus; Hagberg, Lars; Peterson, Julia; Shao, Wei; Spudich, Serena; Price, Richard W; Palmer, Sarah

    2014-05-15

    We sequenced the genome of human immunodeficiency virus type 1 (HIV-1) recovered from 70 cerebrospinal fluid (CSF) specimens and 29 plasma samples and corresponding samples obtained before treatment initiation from 17 subjects receiving suppressive therapy. More CSF sequences than plasma sequences were hypermutants. We determined CSF sequences and plasma sequences in specimens obtained from 2 subjects after treatment initiation. In one subject, we found genetically distinct CSF and plasma sequences, indicating that they came from HIV-1 from 2 different compartments, one potentially the central nervous system, during suppressive therapy. In addition, there was little evidence of viral evolution in the CSF during therapy, suggesting that continuous virus replication is not the major cause of viral persistence in the central nervous system.

  15. Pulsed, atmospheric pressure plasma source for emission spectrometry

    DOEpatents

    Duan, Yixiang; Jin, Zhe; Su, Yongxuan

    2004-05-11

    A low-power, plasma source-based, portable molecular light emission generator/detector employing an atmospheric pressure pulsed-plasma for molecular fragmentation and excitation is described. The average power required for the operation of the plasma is between 0.02 W and 5 W. The features of the optical emission spectra obtained with the pulsed plasma source are significantly different from those obtained with direct current (dc) discharge higher power; for example, strong CH emission at 431.2 nm which is only weakly observed with dc plasma sources was observed, and the intense CN emission observed at 383-388 nm using dc plasma sources was weak in most cases. Strong CN emission was only observed using the present apparatus when compounds containing nitrogen, such as aniline were employed as samples. The present apparatus detects dimethylsulfoxide at 200 ppb using helium as the plasma gas by observing the emission band of the CH radical. When coupled with a gas chromatograph for separating components present in a sample to be analyzed, the present invention provides an apparatus for detecting the arrival of a particular component in the sample at the end of the chromatographic column and the identity thereof.

  16. Lack of reliability of nanotechnology in the of free plasma DNA in samples of patients with prostate cancer

    PubMed Central

    2013-01-01

    Background Several studies seek biological markers that give diagnostic and degree of tumor development. The aim of this study was to validate the determination of plasma DNA using nanotechnology (Nanovue™-NV) in samples of 80 patients with prostate cancer. Methods Blood samples of 80 patients of the Urology Ambulatory of Faculdade de Medicina do ABC with prostate cancer confirmed by anatomical-pathology criteria were analyzed. DNA extraction was performed using a GFX TM kit (Amersham Pharmacia Biotech, Inc, USA) following the adapted protocol. Plasma was subjected to centrifugation. Results There was a big difference between the first and the second value obtained by NanoVue Only two samples had no differences between duplicates. Maximum difference between duplicates was 38 μg/mL. Average variation between 51 samples was 10.29 μg/mL, although 21 samples had differences above this average. No correlation was observed between pDNA obtained by traditional spectrophotometry and by nanotechnology. Conclusion Determination of plasma DNA by nanotechnology was not reproducible. PMID:23311763

  17. Interlaboratory trial for the measurement of total cobalt in equine urine and plasma by ICP-MS.

    PubMed

    Popot, Marie-Agnes; Ho, Emmie N M; Stojiljkovic, Natali; Bagilet, Florian; Remy, Pierre; Maciejewski, Pascal; Loup, Benoit; Chan, George H M; Hargrave, Sabine; Arthur, Rick M; Russo, Charlie; White, James; Hincks, Pamela; Pearce, Clive; Ganio, George; Zahra, Paul; Batty, David; Jarrett, Mark; Brooks, Lydia; Prescott, Lise-Anne; Bailly-Chouriberry, Ludovic; Bonnaire, Yves; Wan, Terence S M

    2017-09-01

    Cobalt is an essential mineral micronutrient and is regularly present in equine nutritional and feed supplements. Therefore, cobalt is naturally present at low concentrations in biological samples. The administration of cobalt chloride is considered to be blood doping and is thus prohibited. To control the misuse of cobalt, it was mandatory to establish an international threshold for cobalt in plasma and/or in urine. To achieve this goal, an international collaboration, consisting of an interlaboratory comparison between 5 laboratories for the urine study and 8 laboratories for the plasma study, has been undertaken. Quantification of cobalt in the biological samples was performed by inductively coupled plasma-mass spectrometry (ICP-MS). Ring tests were based on the analysis of 5 urine samples supplemented at concentrations ranging from 5 up to 500 ng/mL and 5 plasma samples spiked at concentrations ranging from 0.5 up to 25 ng/mL. The results obtained from the different laboratories were collected, compiled, and compared to assess the reproducibility and robustness of cobalt quantification measurements. The statistical approach for the ring test for total cobalt in urine was based on the determination of percentage deviations from the calculated means, while robust statistics based on the calculated median were applied to the ring test for total cobalt in plasma. The inter-laboratory comparisons in urine and in plasma were successful so that 97.6% of the urine samples and 97.5% of the plasma samples gave satisfactory results. Threshold values for cobalt in plasma and urine were established from data only obtained by laboratories involved in the ring test. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.

  18. A comparison of serum and plasma cytokine values using a multiplexed assay in cats.

    PubMed

    Gruen, Margaret E; Messenger, Kristen M; Thomson, Andrea E; Griffith, Emily H; Paradise, Hayley; Vaden, Shelly; Lascelles, B D X

    2016-12-01

    Degenerative joint disease (DJD) is highly prevalent in cats, and pain contributes to morbidity. In humans, alterations of cytokine concentrations have been associated with joint deterioration and pain. Similar changes have not been investigated in cats. Cytokine concentrations can be measured using multiplex technology with small samples of serum or plasma, however, serum and plasma are not interchangeable for most bioassays. Correlations for cytokine concentrations between serum and plasma have not been evaluated in cats. To evaluate the levels of detection and agreement between serum and plasma samples in cats. Paired serum and plasma samples obtained from 38 cats. Blood was collected into anti-coagulant free and EDTA Vacutainer ® tubes, serum or plasma extracted, and samples frozen at -80°C until testing. Duplicate samples were tested using a 19-plex feline cytokine/chemokine magnetic bead panel. Agreement between serum and plasma for many analytes was high, however correlation coefficients ranged from -0.01 to 0.97. Results from >50% of samples were below the lower limit of quantification for both serum and plasma for nine analytes, and for an additional three analytes for plasma only. While serum and plasma agreement was generally good, detection was improved using serum samples. Copyright © 2016 Elsevier B.V. All rights reserved.

  19. Plasma-surface modification vs air oxidation on carbon obtained from peach stone: Textural and chemical changes and the efficiency as adsorbents

    NASA Astrophysics Data System (ADS)

    De Velasco Maldonado, Paola S.; Hernández-Montoya, Virginia; Montes-Morán, Miguel A.

    2016-10-01

    Carbons were prepared from peach stones (Prunus persica) using different carbonization temperatures (600, 800 and 1000 °C). A selected sample was modified by oxidation using conventional oxidation techniques (thermal treatment in air atmosphere) and with cold oxygen plasma oxidation, under different conditions. Samples were characterized using elemental analysis, FT-IR spectroscopy, nitrogen adsorption isotherms at -196 °C, SEM/EDX analysis, potentiometric titration and XPS analysis. Carbons with and without oxidation were employed in the adsorption of Pb2+ in aqueous solution. Results obtained indicated that the materials with high contents of acidic oxygen groups were more efficient in the removal of Pb2+, values as high as approx. 40 mg g-1 being obtained for the best performing carbon. Textural properties of the original, un-oxidized carbon were significantly altered only after oxidation under air atmosphere at 450 °C. On the other hand, the samples oxidized with plasma show little changes in the textural parameters and a slight increase in the specific surface was observed for the sample treated at high RF power (100 W). Additionally, a significant increment of the oxygen content was observed for the plasma oxidized samples, as measured by XPS.

  20. Desizing of Starch Containing Cotton Fabrics Using Near Atmospheric Pressure, Cold DC Plasma Treatment

    NASA Astrophysics Data System (ADS)

    Prasath, A.; Sivaram, S. S.; Vijay Anand, V. D.; Dhandapani, Saravanan

    2013-03-01

    An attempt has been made to desize the starch containing grey cotton fabrics using the DC plasma with oxygen as the gaseous medium. Process conditions of the plasma reactor were optimized in terms of distance between the plates (3.2 cm), applied voltage (600 V) and applied pressure (0.01 bar) to obtain maximum desizing efficiency. No discolouration was observed in the hot water extracts of the desized sample in presence of iodine though relatively higher solvent extractable impurities (4.53 %) were observed in the plasma desized samples compared to acid desized samples (3.38 %). Also, significant weight loss, improvements in plasma desized samples were observed than that of grey fabrics in terms of drop absorbency.

  1. The use of frozen plasma samples in thromboelastometry.

    PubMed

    Schoergenhofer, Christian; Buchtele, Nina; Schwameis, Michael; Bartko, Johann; Jilma, Bernd; Jilma-Stohlawetz, Petra

    2017-11-01

    Thromboelastometry is increasingly used in the clinical and scientific setting. The use of frozen plasma samples may be useful in overcoming certain limitations such as local and timely availability. Whole blood (WB) samples of 20 healthy volunteers were obtained, and plasma was generated. NATEM (n = 20), EXTEM (n = 20) and INTEM (n = 8) analyses were performed in WB, fresh plasma and frozen and thawed plasma. Dabigatran (500, 1000 ng/ml), rivaroxaban (100, 200 ng/ml) or alteplase (333 ng/ml) were added ex vivo to WB, and thromboelastometry was performed in WB and in frozen and thawed plasma samples. Clot formation time, mean clot firmness and the area under the curve were significantly altered in plasma compared to WB. In INTEM and EXTEM analysis, clotting time (CT) was comparable between WB (100%) and fresh (INTEM 114% and EXTEM 93%, ratio of the means) and frozen plasma samples (85 and 99%), whereas in NATEM analysis, the CT increased in fresh (193%) and frozen plasma samples (130%). Dabigatran dose-dependently increased the CT approximately 5- and 9-fold in WB and even more pronounced 10- and 26-fold in plasma. Accordingly, rivaroxaban dose-dependently increased the CT 2- and 2.7-fold in WB, and 3.5- and 4-fold in plasma samples. Hyperfibrinolysis was achieved by addition of alteplase in all WB samples and was reproducible in plasma samples. In conclusion, thromboelastometry, especially INTEM and EXTEM analyses, is possible using frozen and stored plasma samples with comparable results to the corresponding whole blood samples.

  2. Comparison of biochemical values in serum and plasma, fresh and frozen plasma, and hemolyzed samples from orange-winged Amazon parrots (Amazona amazonica).

    PubMed

    Hawkins, Michelle G; Kass, Philip H; Zinkl, Joseph G; Tell, Lisa A

    2006-06-01

    To the authors' knowledge, on the basis of sample type, storage condition, or hemolysis, differences in serum and plasma biochemical values have not been evaluated in orange-winged Amazon parrots (Amazona amazonica). The purpose of this study was to compare values for biochemical analytes in serum vs plasma, fresh vs frozen plasma, and nonhemolyzed vs hemolyzed samples in orange-winged Amazon parrots. We also compared differences in serum and plasma yield from whole-blood aliquots. Fifteen biochemical analytes were evaluated in paired serum and plasma, fresh and frozen plasma, nonhemolyzed and hemolyzed serum and plasma samples from orange-winged Amazon parrots (n = 10) using a wet reagent analyzer. Hemolysis was assessed qualitatively (visually) and quantitatively (hemoglobin [Hgb] measured spectrophotometrically). Serum and plasma yields from 500-microl whole-blood aliquots were determined from centrifuged samples. Analyte values significantly differed among sample groups, but were still within published reference intervals, with the exception of increases in potassium concentration in markedly hemolyzed serum and plasma samples. Clinically important changes in hemolyzed serum and plasma samples included increases in potassium, phosphorus, and albumin concentrations and lactate dehydrogenase activity. The degree of hemolysis assigned qualitatively did not correlate with quantitative Hgb concentration. A significantly greater yield of plasma (288 +/- 13 microL) than serum (241 +/- 44 microL) was obtained. Significant differences may occur in different sample types, however, only changes in potassium, phosphorus, albumin, and lactate dehydrogenase values in hemolyzed samples were considered clinically relevant. Lack of agreement between qualitative and quantitative Hgb concentration indicates the unreliability of visual estimation. Based on higher sample yield, and lack of clinically relevant differences from serum, plasma is a better sample choice for clinical chemistry analysis in birds.

  3. Development of alternative plasma sources for cavity ring-down measurements of mercury.

    PubMed

    Duan, Yixiang; Wang, Chuji; Scherrer, Susan T; Winstead, Christopher B

    2005-08-01

    We have been exploring innovative technologies for elemental and hyperfine structure measurements using cavity ring-down spectroscopy (CRDS) combined with various plasma sources. A laboratory CRDS system utilizing a tunable dye laser is employed in this work to demonstrate the feasibility of the technology. An in-house fabricated sampling system is used to generate aerosols from solution samples and introduce the aerosols into the plasma source. The ring-down signals are monitored using a photomultiplier tube and recorded using a digital oscilloscope interfaced to a computer. Several microwave plasma discharge devices are tested for mercury CRDS measurement. Various discharge tubes have been designed and tested to reduce background interference and increase the sample path length while still controlling turbulence generated from the plasma gas flow. Significant background reduction has been achieved with the implementation of the newly designed tube-shaped plasma devices, which has resulted in a detection limit of 0.4 ng/mL for mercury with the plasma source CRDS. The calibration curves obtained in this work readily show that linearity over 2 orders of magnitude can be obtained with plasma-CRDS for mercury detection. In this work, the hyperfine structure of mercury at the experimental plasma temperatures is clearly identified. We expect that plasma source cavity ring-down spectroscopy will provide enhanced capabilities for elemental and isotopic measurements.

  4. FT-IR spectroscopy and multivariate analysis as an auxiliary tool for diagnosis of mental disorders: Bipolar and schizophrenia cases

    NASA Astrophysics Data System (ADS)

    Ogruc Ildiz, G.; Arslan, M.; Unsalan, O.; Araujo-Andrade, C.; Kurt, E.; Karatepe, H. T.; Yilmaz, A.; Yalcinkaya, O. B.; Herken, H.

    2016-01-01

    In this study, a methodology based on Fourier-transform infrared spectroscopy and principal component analysis and partial least square methods is proposed for the analysis of blood plasma samples in order to identify spectral changes correlated with some biomarkers associated with schizophrenia and bipolarity. Our main goal was to use the spectral information for the calibration of statistical models to discriminate and classify blood plasma samples belonging to bipolar and schizophrenic patients. IR spectra of 30 samples of blood plasma obtained from each, bipolar and schizophrenic patients and healthy control group were collected. The results obtained from principal component analysis (PCA) show a clear discrimination between the bipolar (BP), schizophrenic (SZ) and control group' (CG) blood samples that also give possibility to identify three main regions that show the major differences correlated with both mental disorders (biomarkers). Furthermore, a model for the classification of the blood samples was calibrated using partial least square discriminant analysis (PLS-DA), allowing the correct classification of BP, SZ and CG samples. The results obtained applying this methodology suggest that it can be used as a complimentary diagnostic tool for the detection and discrimination of these mental diseases.

  5. Biomarkers for lymphoma

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zangar, Richard C.; Varnum, Susan M.

    A biomarker, method, test kit, and diagnostic system for detecting the presence of lymphoma in a person are disclosed. The lymphoma may be Hodgkin's lymphoma or non-Hodgkin's lymphoma. The person may be a high-risk subject. In one embodiment, a plasma sample from a person is obtained. The level of at least one protein listed in Table S3 in the plasma sample is measured. The level of at least one protein in the plasma sample is compared with the level in a normal or healthy subject. The lymphoma is diagnosed based upon the level of the at least one protein inmore » the plasma sample in comparison to the normal or healthy level.« less

  6. Dielectrophoretic isolation and detection of cancer-related circulating cell-free DNA biomarkers from blood and plasma

    PubMed Central

    Sonnenberg, Avery; Marciniak, Jennifer Y.; Skowronski, Elaine A.; Manouchehri, Sareh; Rassenti, Laura; Ghia, Emanuela M.; Widhopf, George F.; Kipps, Thomas J.; Heller, Michael J.

    2014-01-01

    Conventional methods for the isolation of cancer-related circulating cell-free (ccf) DNA from patient blood (plasma) are time consuming and laborious. A DEP approach utilizing a microarray device now allows rapid isolation of ccf-DNA directly from a small volume of unprocessed blood. In this study, the DEP device is used to compare the ccf-DNA isolated directly from whole blood and plasma from 11 chronic lymphocytic leukemia (CLL) patients and one normal individual. Ccf-DNA from both blood and plasma samples was separated into DEP high-field regions, after which cells (blood), proteins, and other biomolecules were removed by a fluidic wash. The concentrated ccf-DNA was detected on-chip by fluorescence, and then eluted for PCR and DNA sequencing. The complete process from blood to PCR required less than 10 min; an additional 15 min was required to obtain plasma from whole blood. Ccf-DNA from the equivalent of 5 µL of CLL blood and 5 µL of plasma was amplified by PCR using Ig heavy-chain variable (IGHV) specific primers to identify the unique IGHV gene expressed by the leukemic B-cell clone. The PCR and DNA sequencing results obtained by DEP from all 11 CLL blood samples and from 8 of the 11 CLL plasma samples were exactly comparable to the DNA sequencing results obtained from genomic DNA isolated from CLL patient leukemic B cells (gold standard). PMID:24723219

  7. Dielectrophoretic isolation and detection of cancer-related circulating cell-free DNA biomarkers from blood and plasma.

    PubMed

    Sonnenberg, Avery; Marciniak, Jennifer Y; Skowronski, Elaine A; Manouchehri, Sareh; Rassenti, Laura; Ghia, Emanuela M; Widhopf, George F; Kipps, Thomas J; Heller, Michael J

    2014-07-01

    Conventional methods for the isolation of cancer-related circulating cell-free (ccf) DNA from patient blood (plasma) are time consuming and laborious. A DEP approach utilizing a microarray device now allows rapid isolation of ccf-DNA directly from a small volume of unprocessed blood. In this study, the DEP device is used to compare the ccf-DNA isolated directly from whole blood and plasma from 11 chronic lymphocytic leukemia (CLL) patients and one normal individual. Ccf-DNA from both blood and plasma samples was separated into DEP high-field regions, after which cells (blood), proteins, and other biomolecules were removed by a fluidic wash. The concentrated ccf-DNA was detected on-chip by fluorescence, and then eluted for PCR and DNA sequencing. The complete process from blood to PCR required less than 10 min; an additional 15 min was required to obtain plasma from whole blood. Ccf-DNA from the equivalent of 5 μL of CLL blood and 5 μL of plasma was amplified by PCR using Ig heavy-chain variable (IGHV) specific primers to identify the unique IGHV gene expressed by the leukemic B-cell clone. The PCR and DNA sequencing results obtained by DEP from all 11 CLL blood samples and from 8 of the 11 CLL plasma samples were exactly comparable to the DNA sequencing results obtained from genomic DNA isolated from CLL patient leukemic B cells (gold standard). © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. Bacteria-killing ability of fresh blood plasma compared to frozen blood plasma

    DOE PAGES

    Jacobs, Anne C.; Fair, Jeanne Marie

    2015-10-09

    In recent years, the bacteria-killing assay (BKA) has become a popular technique among ecoimmunologists. New variations of that assay allow researchers to use smaller volumes of blood, an important consideration for those working on small-bodied animals. However, this version of the assay requires access to a lab with a nanodrop spectrophotometer, something that may not be available in the field. One possible solution is to freeze plasma for transport; however, this assumes that frozen plasma samples will give comparable results to fresh ones. Here, we tested this assumption using plasma samples from three species of birds: chickens (Gallus gallus), ash-throatedmore » flycatchers (Myiarchus cinerascens), and western bluebirds (Sialia mexicana). Chicken plasma samples lost most or all of their bacterial killing ability after freezing. This did not happen in flycatchers and bluebirds; however, frozen plasma did not produce results comparable to those obtained using fresh plasma. Finally, we caution researchers using the BKA to use fresh samples whenever possible, and to validate the use of frozen samples on a species-by-species basis.« less

  9. Bacteria-killing ability of fresh blood plasma compared to frozen blood plasma.

    PubMed

    Jacobs, Anne C; Fair, Jeanne M

    2016-01-01

    In recent years, the bacteria-killing assay (BKA) has become a popular technique among ecoimmunologists. New variations of that assay allow researchers to use smaller volumes of blood, an important consideration for those working on small-bodied animals. However, this version of the assay requires access to a lab with a nanodrop spectrophotometer, something that may not be available in the field. One possible solution is to freeze plasma for transport; however, this assumes that frozen plasma samples will give comparable results to fresh ones. We tested this assumption using plasma samples from three species of birds: chickens (Gallus gallus), ash-throated flycatchers (Myiarchus cinerascens), and western bluebirds (Sialia mexicana). Chicken plasma samples lost most or all of their bacterial killing ability after freezing. This did not happen in flycatchers and bluebirds; however, frozen plasma did not produce results comparable to those obtained using fresh plasma. We caution researchers using the BKA to use fresh samples whenever possible, and to validate the use of frozen samples on a species-by-species basis. Copyright © 2015 Elsevier Inc. All rights reserved.

  10. Bacteria-killing ability of fresh blood plasma compared to frozen blood plasma

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jacobs, Anne C.; Fair, Jeanne Marie

    In recent years, the bacteria-killing assay (BKA) has become a popular technique among ecoimmunologists. New variations of that assay allow researchers to use smaller volumes of blood, an important consideration for those working on small-bodied animals. However, this version of the assay requires access to a lab with a nanodrop spectrophotometer, something that may not be available in the field. One possible solution is to freeze plasma for transport; however, this assumes that frozen plasma samples will give comparable results to fresh ones. Here, we tested this assumption using plasma samples from three species of birds: chickens (Gallus gallus), ash-throatedmore » flycatchers (Myiarchus cinerascens), and western bluebirds (Sialia mexicana). Chicken plasma samples lost most or all of their bacterial killing ability after freezing. This did not happen in flycatchers and bluebirds; however, frozen plasma did not produce results comparable to those obtained using fresh plasma. Finally, we caution researchers using the BKA to use fresh samples whenever possible, and to validate the use of frozen samples on a species-by-species basis.« less

  11. Porous Silicon Antibody Microarrays for Quantitative Analysis: Measurement of Free and Total PSA in Clinical Plasma Samples

    PubMed Central

    Tojo, Axel; Malm, Johan; Marko-Varga, György; Lilja, Hans; Laurell, Thomas

    2014-01-01

    The antibody microarrays have become widespread, but their use for quantitative analyses in clinical samples has not yet been established. We investigated an immunoassay based on nanoporous silicon antibody microarrays for quantification of total prostate-specific-antigen (PSA) in 80 clinical plasma samples, and provide quantitative data from a duplex microarray assay that simultaneously quantifies free and total PSA in plasma. To further develop the assay the porous silicon chips was placed into a standard 96-well microtiter plate for higher throughput analysis. The samples analyzed by this quantitative microarray were 80 plasma samples obtained from men undergoing clinical PSA testing (dynamic range: 0.14-44ng/ml, LOD: 0.14ng/ml). The second dataset, measuring free PSA (dynamic range: 0.40-74.9ng/ml, LOD: 0.47ng/ml) and total PSA (dynamic range: 0.87-295ng/ml, LOD: 0.76ng/ml), was also obtained from the clinical routine. The reference for the quantification was a commercially available assay, the ProStatus PSA Free/Total DELFIA. In an analysis of 80 plasma samples the microarray platform performs well across the range of total PSA levels. This assay might have the potential to substitute for the large-scale microtiter plate format in diagnostic applications. The duplex assay paves the way for a future quantitative multiplex assay, which analyses several prostate cancer biomarkers simultaneously. PMID:22921878

  12. A 43-year-old woman with unexplained elevation of hCG.

    PubMed

    Johnson, Lisa M; Gniadek, Thomas J; Cohn, Claudia S; Bachowski, Gary; Karger, Amy B

    2018-05-01

    This case report investigates an unusual hCG result in a woman who is not pregnant. A 43-year-old woman was admitted for recurrence of thrombotic thrombocytopenic purpura (TTP) and therapeutic plasma exchange (TPE) was initiated. Prior to transitioning the patient from TPE to immunosuppressive therapy, a serum qualitative hCG test was performed and was positive. Several etiologies for elevated hCG were considered and investigated, including heterophile antibody interference, endogenous hCG from pituitary or malignancy, and exogenous hCG. Retrospective measurement of hCG levels in remnant samples, including a sample obtained prior to TPE initiation, demonstrated that the hCG elevation occurred with plasma administration for TPE. Further investigation with the American Red Cross confirmed that a plasma donor was unknowingly pregnant and in the latter half of the first trimester at the time of donation, when hCG levels peak. In plasma recipients with unexplained hCG elevation, passive transfer of hCG from plasma should be considered in the differential diagnosis. Retrospective measurement of hCG in remnant samples obtained prior to plasma exchange can assist in confirming the source. Copyright © 2018 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  13. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ctibor, Pavel; Kotlan, Jiri, E-mail: kotlan@ipp.cas.cz; Department of Electrotechnology, Faculty of Electrical Engineering, Czech Technical University in Prague, Technicka 2, Prague 6

    Highlights: • Calcium titanate was sprayed by two different plasma spray systems. • Significant improvement of dielectric properties after annealing was observed. • Calcium titanate self-supporting parts can be fabricated by plasma spraying. - Abstract: This paper studies calcium titanate (CaTiO{sub 3}) dielectrics prepared by plasma spray technology. A water stabilized plasma gun (WSP) as well as a widely used gas stabilized plasma gun (GSP) were employed in this study to deposit three sample sets at different spray conditions. Prepared specimens were annealed in air at atmospheric pressure for 2 h at various temperatures from 530 to 1170 °C. X-raymore » diffraction (XRD), Raman spectroscopy and porosity measurements were used for sample characterization. Dielectric spectroscopy was applied to obtain relative permittivity, conductivity and loss factor frequency dependence. Band gap energy was estimated from reflectance measurements. The work is focused on the explanation of changes in microstructure and properties of a plasma sprayed deposit after thermal annealing. Obtained results show significant improvement of dielectric properties after thermal annealing.« less

  14. Long-term in vitro reactivity for HLA antibodies and comparison of detection using serum vs. plasma

    PubMed Central

    Norris, Philip J.; Lee, Jar-How; Carrick, Danielle M.; Gottschall, Jerome L.; Lebedeva, Mila; de Castro, B.R.; Kleinman, Steven H.; Busch, Michael P.

    2010-01-01

    BACKGROUND HLA antibodies are a possible cause of transfusion-related acute lung injury (TRALI), and fluorescent bead assays are often used for antibody detection. Serum is the manufacturer’s recommended sample, but plasma may be easier to obtain for studies of HLA antibody prevalence and TRALI case investigations. STUDY DESIGN AND METHODS Specimens were obtained from 44 multiparous females positive for HLA antibodies by lymphocytotoxicity testing at least 13 years prior, and from 1,000 contemporary blood donors. Screening tests were performed using a Luminex-based assay. In addition to comparing results obtained with paired plasma and serum samples, the effects of storage at 4 °C for one week and of multiple freeze-thaw cycles were evaluated. RESULTS Of 42 evaluable subjects with HLA antibodies documented >13 years earlier, only 1 showed loss of detectable antibodies, with 39 (93%) positive in the screening assay for class I and 24 (57%) positive in the screening assay for HLA class II antibodies. In 968 evaluable contemporary donors, 291 screened positive for HLA class I and 206 for HLA class II antibodies using a low assay cut-off. Screening test concordance using paired plasma and serum samples was high, particularly for subjects with higher level antibodies. Refrigeration of samples for one week did not significantly affect assay results, while repeated freeze-thaw cycles caused a decrement in signal level. CONCLUSION Serum and plasma samples gave concordant results in the majority of cases, particularly for specimens with higher-level antibodies. High-level HLA antibodies were present in most individuals for over 13 years. PMID:18980615

  15. Intrapulmonary concentration of enrofloxacin in healthy calves

    PubMed Central

    OTOMARU, Konosuke; HIRATA, Masaya; IKEDO, Tomonobu; HORINOUCHI, Chie; NOGUCHI, Michiko; ISHIKAWA, Shingo; NAGATA, Shun-ichi; HOBO, Seiji

    2015-01-01

    To determine the intrapulmonary concentration of enrofloxacin (ERFX) in calves, plasma, bronchoalveolar lavage fluid (BALF) and alveolar cells samples were obtained from clinically healthy calves. Four clinically healthy calves were administered a single dose of ERFX (5 mg/kg) by subcutaneous injection. Samples of plasma were obtained for each subjects at 0 (before administration), 1 and 2 hr after administration of ERFX. Samples of BALF were obtained from each subject at 0, 1 and 2 hr after administration of ERFX. This examination was conducted two times, one week apart. The mean EFRX concentrations in plasma at 1 and 2 hr after administration were l.23 and 1.29 µg/ml, respectively. The mean EFRX concentrations in pulmonary epithelial lining fluid (ELF) at 1 and 2 hr after administration 8.53 µg/ml and 9.42 µg/ml, respectively. The mean ERFX concentrations of alveolar cells in BALF at 1 and 2 hr after administration were 4.04 µg/ml and 5.19 µg/ml, respectively. These results suggest that the ERFX concentrations in ELF and alveolar cells concentrations in BALF at 1 and 2 hr after administration were higher than the plasma concentrations. PMID:26668174

  16. Stability of hemostatic proteins in canine fresh-frozen plasma thawed with a modified commercial microwave warmer or warm water bath.

    PubMed

    Pashmakova, Medora B; Barr, James W; Bishop, Micah A

    2015-05-01

    To compare stability of hemostatic proteins in canine fresh-frozen plasma (FFP) thawed with a modified commercial microwave warmer (MCM) or warm water bath (37°C; WWB) or at room temperature (22°C). Fresh-frozen plasma obtained from 8 canine donors of a commercial blood bank. A commercial microwave warmer was modified with a thermocouple to measure surface temperature of bags containing plasma. The MCM and a WWB were each used to concurrently thaw a 60-mL bag of plasma obtained from the same donor. Two 3-mL control aliquots of FFP from each donor were thawed to room temperature without use of a heating device. Concentrations of hemostatic proteins, albumin, and D-dimers; prothrombin time (PT); and activated partial thromboplastin time (aPTT) were determined for all samples. Significant decreases in concentrations of factors II, IX, X, XI, fibrinogen, von Willebrand factor, antithrombin, protein C, and albumin and significant increases in PT and aPTT were detected for plasma thawed with the MCM, compared with results for samples thawed with the WWB. Concentrations of factors VII, VIII, and XII were not significantly different between plasma thawed with the MCM and WWB. Concentrations of D-dimers were above the reference range for all thawed samples regardless of thawing method. No significant differences in factor concentrations were detected between control and WWB-thawed samples. Significant differences in hemostatic protein concentrations and coagulation times were detected for plasma thawed with an MCM but not between control and WWB-thawed samples. Clinical importance of these changes should be investigated.

  17. Integrated analytical approach in veal calves administered the anabolic androgenic steroids boldenone and boldione: urine and plasma kinetic profile and changes in plasma protein expression.

    PubMed

    Draisci, Rosa; Montesissa, Clara; Santamaria, Barbara; D'Ambrosio, Chiara; Ferretti, Giovanni; Merlanti, Roberta; Ferranti, Carolina; De Liguoro, Marco; Cartoni, Claudia; Pistarino, Erika; Ferrara, Lino; Tiso, Micaela; Scaloni, Andrea; Cosulich, M Elisabetta

    2007-09-01

    Surveillance of illegal use of steroids hormones in cattle breeding is a key issue to preserve human health. To this purpose, an integrated approach has been developed for the analysis of plasma and urine from calves treated orally with a single dose of a combination of the androgenic steroids boldenone and boldione. A quantitative estimation of steroid hormones was obtained by LC-APCI-Q-MS/MS analysis of plasma and urine samples obtained at various times up to 36 and 24 h after treatment, respectively. These experiments demonstrated that boldione was never found, while boldenone alpha- and beta-epimers were detected in plasma and urine only within 2 and 24 h after drug administration, respectively. Parallel proteomic analysis of plasma samples was obtained by combined 2-DE, MALDI-TOF-MS and muLC-ESI-IT-MS/MS procedures. A specific protein, poorly represented in normal plasma samples collected before treatment, was found upregulated even 36 h after hormone treatment. Extensive mass mapping experiments proved this component as an N-terminal truncated form of apolipoprotein A1 (ApoA1), a protein involved in cholesterol transport. The expression profile of ApoA1 analysed by Western blot analysis confirmed a significant and time dependent increase of this ApoA1 fragment. Then, provided that further experiments performed with a growth-promoting schedule will confirm these preliminary findings, truncated ApoA1 may be proposed as a candidate biomarker for steroid boldenone and possibly other anabolic androgens misuse in cattle veal calves, when no traces of hormones are detectable in plasma or urine.

  18. An integrated bioanalytical method development and validation approach: case studies.

    PubMed

    Xue, Y-J; Melo, Brian; Vallejo, Martha; Zhao, Yuwen; Tang, Lina; Chen, Yuan-Shek; Keller, Karin M

    2012-10-01

    We proposed an integrated bioanalytical method development and validation approach: (1) method screening based on analyte's physicochemical properties and metabolism information to determine the most appropriate extraction/analysis conditions; (2) preliminary stability evaluation using both quality control and incurred samples to establish sample collection, storage and processing conditions; (3) mock validation to examine method accuracy and precision and incurred sample reproducibility; and (4) method validation to confirm the results obtained during method development. This integrated approach was applied to the determination of compound I in rat plasma and compound II in rat and dog plasma. The effectiveness of the approach was demonstrated by the superior quality of three method validations: (1) a zero run failure rate; (2) >93% of quality control results within 10% of nominal values; and (3) 99% incurred sample within 9.2% of the original values. In addition, rat and dog plasma methods for compound II were successfully applied to analyze more than 900 plasma samples obtained from Investigational New Drug (IND) toxicology studies in rats and dogs with near perfect results: (1) a zero run failure rate; (2) excellent accuracy and precision for standards and quality controls; and (3) 98% incurred samples within 15% of the original values. Copyright © 2011 John Wiley & Sons, Ltd.

  19. Ion Beam And Plasma Jet Generated By A 3 kJ Plasma Focus

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lim, L. K.; Ngoi, S. K.; Yap, S. L.

    The plasma focus device is well known as a copious source of X-ray, neutrons, ion and electron beams. In this work, the characteristics of energetic ion beam emission in a 3 kJ Mather-type plasma focus is studied. The plasma focus system is operated at low pressure with argon as the working gas. The objective of the project is to obtain the argon ion beam and the plasma jet. The ion beam and plasma jet are used for material processing. In order to investigate the effect of the ion beam and plasma jet, crystalline silicon substrates are placed above the anode.more » Samples obtained after irradiation with the plasma focus discharge are analyzed by using the Scanning electron microscopy (SEM) and Energy Dispersive X-ray spectroscopy (EDX).« less

  20. A system of equations to approximate the pharmacokinetic parameters of lacosamide at steady state from one plasma sample.

    PubMed

    Cawello, Willi; Schäfer, Carina

    2014-08-01

    Frequent plasma sampling to monitor pharmacokinetic (PK) profile of antiepileptic drugs (AEDs), is invasive, costly and time consuming. For drugs with a well-defined PK profile, such as AED lacosamide, equations can accurately approximate PK parameters from one steady-state plasma sample. Equations were derived to approximate steady-state peak and trough lacosamide plasma concentrations (Cpeak,ss and Ctrough,ss, respectively) and area under concentration-time curve during dosing interval (AUCτ,ss) from one plasma sample. Lacosamide (ka: ∼2 h(-1); ke: ∼0.05 h(-1), corresponding to half-life of 13 h) was calculated to reach Cpeak,ss after ∼1 h (tmax,ss). Equations were validated by comparing approximations to reference PK parameters obtained from single plasma samples drawn 3-12h following lacosamide administration, using data from double-blind, placebo-controlled, parallel-group PK study. Values of relative bias (accuracy) between -15% and +15%, and root mean square error (RMSE) values≤15% (precision) were considered acceptable for validation. Thirty-five healthy subjects (12 young males; 11 elderly males, 12 elderly females) received lacosamide 100mg/day for 4.5 days. Equation-derived PK values were compared to reference mean Cpeak,ss, Ctrough,ss and AUCτ,ss values. Equation-derived PK data had a precision of 6.2% and accuracy of -8.0%, 2.9%, and -0.11%, respectively. Equation-derived versus reference PK values for individual samples obtained 3-12h after lacosamide administration showed correlation (R2) range of 0.88-0.97 for AUCτ,ss. Correlation range for Cpeak,ss and Ctrough,ss was 0.65-0.87. Error analyses for individual sample comparisons were independent of time. Derived equations approximated lacosamide Cpeak,ss, Ctrough,ss and AUCτ,ss using one steady-state plasma sample within validation range. Approximated PK parameters were within accepted validation criteria when compared to reference PK values. Copyright © 2014 Elsevier B.V. All rights reserved.

  1. Comparison of Performance Characteristics of Aspergillus PCR in Testing a Range of Blood-Based Samples in Accordance with International Methodological Recommendations.

    PubMed

    Springer, Jan; White, P Lewis; Hamilton, Shanna; Michel, Denise; Barnes, Rosemary A; Einsele, Hermann; Löffler, Juergen

    2016-03-01

    Standardized methodologies for the molecular detection of invasive aspergillosis (IA) have been established by the European Aspergillus PCR Initiative for the testing of whole blood, serum, and plasma. While some comparison of the performance of Aspergillus PCR when testing these different sample types has been performed, no single study has evaluated all three using the recommended protocols. Standardized Aspergillus PCR was performed on 423 whole-blood pellets (WBP), 583 plasma samples, and 419 serum samples obtained from hematology patients according to the recommendations. This analysis formed a bicenter retrospective anonymous case-control study, with diagnosis according to the revised European Organization for Research and Treatment of Cancer/Invasive Fungal Infections Cooperative Group and National Institute of Allergy and Infectious Diseases Mycoses Study Group (EORTC/MSG) consensus definitions (11 probable cases and 36 controls). Values for clinical performance using individual and combined samples were calculated. For all samples, PCR positivity was significantly associated with cases of IA (for plasma, P = 0.0019; for serum, P = 0.0049; and for WBP, P = 0.0089). Plasma PCR generated the highest sensitivity (91%); the sensitivities for serum and WBP PCR were 80% and 55%, respectively. The highest specificity was achieved when testing WBP (96%), which was significantly superior to the specificities achieved when testing serum (69%, P = 0.0238) and plasma (53%, P = 0.0002). No cases were PCR negative in all specimen types, and no controls were PCR positive in all specimens. This study confirms that Aspergillus PCR testing of plasma provides robust performance while utilizing commercial automated DNA extraction processes. Combining PCR testing of different blood fractions allows IA to be both confidently diagnosed and excluded. A requirement for multiple PCR-positive plasma samples provides similar diagnostic utility and is technically less demanding. Time to diagnosis may be enhanced by testing multiple contemporaneously obtained sample types. Copyright © 2016, American Society for Microbiology. All Rights Reserved.

  2. Improvement in the performance of external quality assessment in Korean HIV clinical laboratories using unrecalcified human plasma.

    PubMed

    Wang, Jin-Sook; Kee, Mee-Kyung; Choi, Byeong-Sun; Kim, Chan-Wha; Kim, Hyon-Suk; Kim, Sung Soon

    2012-01-01

    The external quality assessment schemes (EQAS) organizer provides a suitable program to monitor and improve the quality of human immunodeficiency virus (HIV) testing laboratories with EQAS panels prepared under various conditions. The aim of the current study was to investigate the effects of human plasma samples on the EQAS results of HIV obtained from hospital-based clinical laboratories. From 2007 to 2009, HIV EQAS panels consisted of four to six samples that consisted of undiluted positive and negative samples and were provided to laboratories twice per year. Up until the first half EQAS in 2008, EQAS panel materials were obtained by converting acid citrate dextrose treated plasma to serum via chemical treatment with CaCl2. Beginning with the second EQAS in 2008, all materials were prepared without the defibrination process. Approximately 300 HIV clinical laboratories participated in this program. The overall performance of clinical laboratories was shown to be improved when using unrecalcified plasma panels compared with recalcified panels. Significant differences were observed in EIA analyses of plasma for both positive (p<0.001) and negative (p<0.001) samples between the recalcified and unrecalcified groups. Our finding suggested that defibrination status of EQAS panels might affect the results of anti-HIV EQAS of Korean HIV testing laboratories.

  3. Plasma assisted facile synthesis of vanadium oxide (V3O7) nanostructured thin films

    NASA Astrophysics Data System (ADS)

    Singh, Megha; Saini, Sujit K.; Kumar, Prabhat; Sharma, Rabindar K.; Reddy, G. B.

    2018-05-01

    Vanadium oxides nanostructured thin films are synthesized using plasma assisted sublimation process. The effect of temperatures on growth of V2O5 and V3O7 thin films is studied. Scanning electron micrographs shows different morphologies are obtained at different temperatures i.e. at 450 °C nano cubes-like structures are obtained, whereas at 550 °C and 650 °C nanorods are obtained. Sample deposited at 450 °C is entirely composed of V2O5 and sample at higher temperatures are composed of mixed phase of vanadium oxides i.e. V2O5 and V3O7. As temperature increased, so the content of V3O7 in the sample is increased as confirmed by XRD and Raman analyses.

  4. Simple equation for calculation of plasma clearance for evaluation of renal function without urine collection in rats.

    PubMed

    Liu, Xiang; Peng, Dejun; Tian, Hao; Lu, Chengyu

    2017-01-01

    To develop an equation for the evaluation of renal function in rats using three dilutions of plasma samples and to validate this method by comparison with a reference method. The investigation was conducted in Sprague-Dawley (SD) rats after delivery of three doses of iohexol, with blood samples collected before and after dosage using a quantitative blood collection method. Plasma iohexol concentrations were detected by high performance liquid chromatography (HPLC). The extraction recovery of iohexol from plasma was >97.30% and the calibration curve was linear (r 2  = 0.9997) over iohexol concentrations ranging from 10 to 1000 µg/mL. The method had an RE of <9.310 and intra- and inter-day RSD of <5.137% and <3.693%, respectively. The plasma clearance values obtained from the equation correlated closely (r = 0.763) with those obtained using the reference method. The relatively correlation in the results obtained using the method under investigation and the reference method indicate that this new equation can be used for preliminary assessment of renal function in rats. © 2016 Asian Pacific Society of Nephrology.

  5. The method of synthesizing of superhydrophobic surfaces by PECVD

    NASA Astrophysics Data System (ADS)

    Orazbayev, Sagi; Gabdullin, Maratbek; Ramazanov, Tlekkabul; Dosbolayev, Merlan; Zhunisbekov, Askar; Omirbekov, Dulat; Otarbay, Zhuldyz

    2018-03-01

    The aim of this work was to obtain superhydrophobic surfaces in a plasma medium. The experiment was carried out using the PECVD method in two different modes: constant and pulsing. The surface roughness was obtained by applying nanoparticles synthesized in plasma in a mixture of argon and methane. The resulting particles were deposited on the surface of silicon and glass materials. The contact angle increased linearly depending on the number of cycles, until it reached 160° at 150-160th cycles, after that the increase in cycles does not affect the contact angle, since the saturation process is in progress. Also the effect of the working gas composition on the hydrophobicity of the surface was studied. At low concentrations of methane (1%) only particles are synthesized in the working gas, and hydrophobicity is unstable, with an increase in methane concentration (7%) nanofilms are synthesized from nanoclusters, and surface hydrophobicity is relatively stable. In addition, a pulsing plasma mode was used to obtain superhydrophobic surfaces. The hydrophobicity of the sample showed that the strength of the nanofilm was stable in comparison with the sample obtained in the first mode, but the contact angle was lower. The obtained samples were examined using SEM, SPM, optical analysis, and their contact angles were determined.

  6. Influence of tube type, storage time, and temperature on the total and free concentration of valproic acid.

    PubMed

    Tarasidis, C G; Garnett, W R; Kline, B J; Pellock, J M

    1986-01-01

    The influence of storage conditions on the total and free concentration of valproic acid (VPA) was studied in six normal male subjects who ingested 750 mg of VPA (3 X 250 mg Depakene capsules; Abbott Laboratories). Blood samples were collected in various types of Vacutainer tubes (red top, no additives; green top, sodium heparin; blue top, sodium citrate; and purple top, EDTA) 2 h post administration of VPA. Either these samples were centrifuged immediately or stored for various periods of time at room temperature or refrigerated, or the supernate was frozen prior to analysis. Free VPA samples were obtained utilizing the Amicon ultrafiltration system. All VPA samples were analyzed by gas-liquid chromatography. Total VPA concentrations obtained from plasma collected with sodium citrate were lower (p less than 0.05) than either serum or plasma collected with other anticoagulants. There were no differences (p greater than 0.05) in total or free VPA concentrations between samples collected in serum or in plasma collected with heparin or EDTA. Storing samples for 96 h at room temperature did not alter the total VPA concentrations but was found to increase the free fraction of VPA (p less than 0.05). The refrigeration or freezing of the supernate from the blood samples for 7 days did not alter (p greater than 0.05) the total or the free fraction of VPA. The results of this study demonstrate that total and/or free VPA may be collected from either serum or plasma, provided sodium citrate is not used to collect plasma.(ABSTRACT TRUNCATED AT 250 WORDS)

  7. Ammonia concentrations in canine whole blood, EDTA-anticoagulated whole blood, and plasma measured by use of a point-of-care ammonia meter.

    PubMed

    Odunayo, Adesola; Tobias, Karen M; Okafor, Chika C; Flatland, Bente

    2017-11-01

    OBJECTIVE To investigate the use of canine whole blood (WB) for measurement of ammonia concentration by use of a point-of-care ammonia meter and to compare results of measuring ammonia concentrations in WB, EDTA-anticoagulated WB, and plasma. ANIMALS 40 client-owned dogs. PROCEDURES A blood sample (2 mL) was obtained from each dog. One drop of WB was immediately applied to a test strip for evaluation with an ammonia meter. The remainder of the blood sample was placed in an EDTA-containing tube, and 1 drop of EDTA-anticoagulated WB was applied to a test strip. The remaining EDTA-anticoagulated WB sample was centrifuged, and the plasma was harvested and placed on ice. One drop of plasma was applied to a test strip; the remainder of the plasma sample was transported on ice and used for ammonia measurement with a reference laboratory instrument. All samples were tested within 1 hour after sample collection. Results were evaluated to detect significant differences in ammonia concentration. RESULTS Ammonia concentrations did not differ significantly between WB and EDTA-anticoagulated WB and between plasma samples measured with the meter and reference laboratory instrument. However, median ammonia concentration was significantly higher in plasma than in WB or EDTA-anti-coagulated WB. CONCLUSIONS AND CLINICAL RELEVANCE Anticoagulant-free WB was a valid sample for measurement by use of the ammonia meter. Plasma samples had higher ammonia concentrations than did WB samples. Results for each sample type should be interpreted by use of specimen- and method-specific reference intervals.

  8. Digital PCR analysis of plasma cell-free DNA for non-invasive detection of drug resistance mechanisms in EGFR mutant NSCLC: Correlation with paired tumor samples

    PubMed Central

    Ishii, Hidenobu; Azuma, Koichi; Sakai, Kazuko; Kawahara, Akihiko; Yamada, Kazuhiko; Tokito, Takaaki; Okamoto, Isamu; Nishio, Kazuto; Hoshino, Tomoaki

    2015-01-01

    As the development of resistance to epidermal growth factor receptor (EGFR) tyrosine kinase inhibitors (TKIs) has become an issue of concern, identification of the mechanisms responsible has become an urgent priority. However, for research purposes, it is not easy to obtain tumor samples from patients with EGFR mutation-positive non-small-cell lung cancer (NSCLC) that has relapsed after treatment with EGFR-TKIs. Here, using digital PCR assay as an alternative and noninvasive method, we examined plasma and tumor samples from patients with relapsed NSCLC to establish the inter-relationships existing among T790M mutation, activating EGFR mutations, HER2 amplification, and MET amplification. Paired samples of tumor and blood were obtained from a total of 18 patients with NSCLC after they had developed resistance to EGFR-TKI treatment, and the mechanisms of resistance were analyzed by digital PCR. Digital PCR analysis of T790M mutation in plasma had a sensitivity of 81.8% and specificity of 85.7%, the overall concordance between plasma and tissue samples being 83.3%. MET gene copy number gain in tumor DNA was observed by digital PCR in three patients, of whom one exhibited positivity for MET amplification by FISH, whereas no patient demonstrated MET and HER2 copy number gain in plasma DNA. Digital PCR analysis of plasma is feasible and accurate for detection of T790M mutation in NSCLC that becomes resistant to treatment with EGFR-TKIs. PMID:26334838

  9. Plasma/muscle ratios of sulfadimethoxine residues in channel catfish (Ictalurus punctatus).

    PubMed

    Walker, C C; Thune, R L; Barker, S A

    1995-08-01

    Channel catfish (n = 84) maintained at a water temperature of 27 degrees C were used in a feeding study to determine the plasma to muscle concentration ratios of sulfadimethoxine (SDM) and 4-N-acetylsulfadimethoxine residues. Sulfadimethoxine medicated feed was provided free choice at 42 mg SDM/kg body weight once daily for 5 days and the plasma and muscle concentrations of SDM were determined at selected withdrawal times (6, 12, 24, 48, 72, and 96 hours) following the last dose. Considerable variation in total SDM tissue concentration among fish within a sampling period was observed. For fish (n = 12) at six hours post-dose, total SDM concentrations ranged from 1.4-24.8 micrograms/mL and 0.6-12.6 micrograms/g, with mean total SDM concentrations of 9.1 micrograms/mL and 5.3 micrograms/g for plasma and muscle, respectively. However, a mean plasma:muscle concentration ratio of 1.8:1 +/- 0.3:1 was obtained over all concentrations and sampling periods. The plasma:muscle 95% t distribution interval for individual fish was 1.2:1 to 2.4:1. A correlation coefficient of 0.967 was obtained for the relationship between plasma and muscle total SDM concentration among individual fish (n = 25). Results of this study indicate that plasma total SDM concentration may be used to identify samples containing violative SDM muscle residue. No fish contained total SDM muscle residues greater than the FDA tolerance (0.1 microgram/g) by 48 hours following the final dose.

  10. Quantitative determination of total cesium in highly active liquid waste by using liquid electrode plasma optical emission spectrometry.

    PubMed

    Do, Van-Khoai; Yamamoto, Masahiko; Taguchi, Shigeo; Takamura, Yuzuru; Surugaya, Naoki; Kuno, Takehiko

    2018-06-01

    A sensitive analytical method for determination of total cesium (Cs) in highly active liquid waste (HALW) by using modified liquid electrode plasma optical emission spectrometry (LEP-OES) is developed in this study. The instrument is modified to measure radioactive samples in a glove box. The effects of important factors, including pulsed voltage sequence and nitric acid concentration, on the emission of Cs are investigated. The limit of detection (LOD) and limit of quantification (LOQ) are 0.005 mg/L and 0.02 mg/L, respectively. The achieved LOD is one order lower than that of recently developed spectroscopic methods using liquid discharge plasma. The developed method is validated by subjecting a simulated HALW sample to inductively coupled plasma mass spectrometry (ICP-MS). The recoveries obtained from a spike-and-recovery test are 96-102%, implying good accuracy. The method is successfully applied to the quantification of Cs in a real HALW sample at the Tokai reprocessing plant in Japan. Apart from dilution and filtration of the HALW sample, no other pre-treatment process is required. The results agree well with the values obtained using gamma spectrometry. The developed method offers a reliable technique for rapid analysis of total Cs in HALW samples. Copyright © 2018 Elsevier B.V. All rights reserved.

  11. High voltage solar array experiments

    NASA Technical Reports Server (NTRS)

    Kennerud, K. L.

    1974-01-01

    The interaction between the components of a high voltage solar array and a simulated space plasma is studied to obtain data for the design of a high voltage solar array capable of 15kW at 2 to 16kV. Testing was conducted in a vacuum chamber 1.5-m long by 1.5-m diameter having a plasma source which simulated the plasma conditions existing in earth orbit between 400 nautical miles and synchronous altitude. Test samples included solar array segments pinholes in insulation covering high voltage electrodes, and plain dielectric samples. Quantitative data are presented in the areas of plasma power losses, plasma and high voltage induced damage, and dielectric properties. Limitations of the investigation are described.

  12. Fluorination of vertically aligned carbon nanotubes: from CF4 plasma chemistry to surface functionalization.

    PubMed

    Struzzi, Claudia; Scardamaglia, Mattia; Colomer, Jean-François; Verdini, Alberto; Floreano, Luca; Snyders, Rony; Bittencourt, Carla

    2017-01-01

    The surface chemistry of plasma fluorinated vertically aligned carbon nanotubes (vCNT) is correlated to the CF 4 plasma chemical composition. The results obtained via FTIR and mass spectrometry are combined with the XPS and Raman analysis of the sample surface showing the dependence on different plasma parameters (power, time and distance from the plasma region) on the resulting fluorination. Photoemission and absorption spectroscopies are used to investigate the evolution of the electronic properties as a function of the fluorine content at the vCNT surface. The samples suffer a limited ageing effect, with a small loss of fluorine functionalities after two weeks in ambient conditions.

  13. Fluorination of vertically aligned carbon nanotubes: from CF4 plasma chemistry to surface functionalization

    PubMed Central

    Scardamaglia, Mattia; Colomer, Jean-François; Verdini, Alberto; Floreano, Luca; Snyders, Rony; Bittencourt, Carla

    2017-01-01

    The surface chemistry of plasma fluorinated vertically aligned carbon nanotubes (vCNT) is correlated to the CF4 plasma chemical composition. The results obtained via FTIR and mass spectrometry are combined with the XPS and Raman analysis of the sample surface showing the dependence on different plasma parameters (power, time and distance from the plasma region) on the resulting fluorination. Photoemission and absorption spectroscopies are used to investigate the evolution of the electronic properties as a function of the fluorine content at the vCNT surface. The samples suffer a limited ageing effect, with a small loss of fluorine functionalities after two weeks in ambient conditions. PMID:28904833

  14. Ballistic piston fissioning plasma experiment.

    NASA Technical Reports Server (NTRS)

    Miller, B. E.; Schneider, R. T.; Thom, K.; Lalos, G. T.

    1971-01-01

    The production of fissioning uranium plasma samples such that the fission fragment stopping distance is less than the dimensions of the plasma is approached by using a ballistic piston device for the compression of uranium hexafluoride. The experimental apparatus is described. At room temperature the gun can be loaded up to 100 torr UF6 partial pressure, but at compression a thousand fold increase of pressure can be obtained at a particle density on the order of 10 to the 19th power per cu cm. Limited spectral studies of UF6 were performed while obtaining the pressure-volume data. The results obtained and their implications are discussed.

  15. Influence of storage conditions on in vitro stability of atrial natriuretic peptide and of anesthesia on plasma atrial natriuretic peptide concentration in cats.

    PubMed

    Heishima, Yasuhiro; Hori, Yasutomo; Chikazawa, Seishiro; Kanai, Kazutaka; Hoshi, Fumio; Itoh, Naoyuki

    2016-08-01

    OBJECTIVE To investigate the in vitro stability of atrial natriuretic peptide (ANP) in plasma samples under various storage conditions and the influence of anesthesia on plasma ANP concentration in cats. ANIMALS 1 cat with congestive heart failure and 5 healthy adult mixed-breed cats. PROCEDURES A plasma sample from the cat with heart failure was serially diluted, and dilutional parallelism of ANP concentration was evaluated. Plasma samples containing aprotinin or serum samples from the 5 healthy cats were kept at room temperature (27°C) for ≤ 12 hours. Plasma samples from the same healthy cats were stored at -70°, -20°, or 4°C for ≤ 14 days. Plasma samples were obtained from the healthy cats before and during isoflurane anesthesia. Plasma ANP concentrations were measured at a commercial laboratory by use of a human ANP chemiluminescence assay. RESULTS Intra- and interassay coefficients of variation were 1.5% and 2.5%, respectively, and dilutional parallelism was established. Although ANP concentration decreased by 82.4 ± 13.6% (mean ± SD) after sample storage for 12 hours at room temperature, this decrease was prevented by aprotinin. Plasma ANP concentrations were stable for 7 days at -20°C and for 14 days at -70°C. However, concentrations decreased markedly to 57.6 ± 6.9% at -20°C and to 18.0 ± 3.0% at 4°C after 14 days. Plasma ANP concentration decreased significantly in cats during anesthesia and was correlated with blood pressure. CONCLUSIONS AND CLINICAL RELEVANCE Results suggested that aprotinin should be added routinely in preparation of plasma samples from cats for measurement of ANP concentration, and those samples, if stored, should be frozen immediately at ≤ -20°C. General anesthesia or systemic blood pressure may affect plasma ANP concentration in cats.

  16. A needle extraction utilizing a molecularly imprinted-sol-gel xerogel for on-line microextraction of the lung cancer biomarker bilirubin from plasma and urine samples.

    PubMed

    Moein, Mohammad Mahdi; Jabbar, Dunia; Colmsjö, Anders; Abdel-Rehim, Mohamed

    2014-10-31

    In the present work, a needle trap utilizing a molecularly imprinted sol-gel xerogel was prepared for the on-line microextraction of bilirubin from plasma and urine samples. Each prepared needle could be used for approximately one hundred extractions before it was discarded. Imprinted and non-imprinted sol-gel xerogel were applied for the extraction of bilirubin from plasma and urine samples. The produced molecularly imprinted sol-gel xerogel polymer showed high binding capacity and fast adsorption/desorption kinetics for bilirubin in plasma and urine samples. The adsorption capacity of molecularly imprinted sol-gel xerogel polymer was approximately 60% higher than that of non-imprinted polymer. The effect of the conditioning, washing and elution solvents, pH, extraction time, adsorption capacity and imprinting factor were investigated. The limit of detection and the lower limit of quantification were set to 1.6 and 5nmolL(-1), respectively using plasma or urine samples. The standard calibration curves were obtained within the concentration range of 5-1000nmolL(-1) in both plasma and urine samples. The coefficients of determination values (R(2)) were ≥0.998 for all runs. The extraction recovery was approximately 80% for BR in the human plasma and urine samples. Copyright © 2014 Elsevier B.V. All rights reserved.

  17. The effect of surface nanocrystallization on plasma nitriding behaviour of AISI 4140 steel

    NASA Astrophysics Data System (ADS)

    Li, Yang; Wang, Liang; Zhang, Dandan; Shen, Lie

    2010-11-01

    A plastic deformation surface layer with nanocrystalline grains was produced on AISI 4140 steel by means of surface mechanical attrition treatment (SMAT). Plasma nitriding of SMAT and un-SMAT AISI 4140 steel was carried out by a low-frequency pulse excited plasma unit. A series of nitriding experiments has been conducted at temperatures ranging from 380 to 500 °C for 8 h in an NH 3 gas. The samples were characterized using X-ray diffraction, scanning electron microscopy, optical microscopy and Vickers microhardness tester. The results showed that a much thicker compound layer with higher hardness was obtained for the SMAT samples when compared with un-SMAT samples after nitriding at the low temperature. In particular, plasma nitriding SMAT AISI 4140 steel at 380 °C for 8 h can produced a compound layer of 2.5 μm thickness with very high hardness on the surface, which is similar to un-SMAT samples were plasma nitrided at approximately 430 °C within the same time.

  18. Organochlorine pesticides in plasma of migrating peregrine falcons at Padre Island, Texas, Spring 1978-80 vs. Spring 1984

    USGS Publications Warehouse

    Henny, C.J.; Riddle, K.E.; Hulse, C.S.

    1985-01-01

    A spring concentration of migrating Peregrine Falcons (Falco peregrinus) was first discovered at Padre Island, Texas, in April 1978. The birds were first captured and blood-sampled for monitoring residue burdens and trends in the late 1970' s. Only 29 Peregrines were sampled in 1978 and 1979, but 111 were sampled in 1980. The initial investigation showed that DDE in the plasma of spring migrants returning from Latin America for the first time declined significantly during the study (through 1980). In the spring of 1984, 48 Peregrines were captured at Padre Island with blood samples again collected. This report will compare plasma residue data from the earlier study with residues obtained in 1984.

  19. Using atmospheric pressure plasma treatment for treating grey cotton fabric.

    PubMed

    Kan, Chi-Wai; Lam, Chui-Fung; Chan, Chee-Kooi; Ng, Sun-Pui

    2014-02-15

    Conventional wet treatment, desizing, scouring and bleaching, for grey cotton fabric involves the use of high water, chemical and energy consumption which may not be considered as a clean process. This study aims to investigate the efficiency of the atmospheric pressure plasma (APP) treatment on treating grey cotton fabric when compared with the conventional wet treatment. Grey cotton fabrics were treated with different combinations of plasma parameters with helium and oxygen gases and also through conventional desizing, scouring and bleaching processes in order to obtain comparable results. The results obtained from wicking and water drop tests showed that wettability of grey cotton fabrics was greatly improved after plasma treatment and yielded better results than conventional desizing and scouring. The weight reduction of plasma treated grey cotton fabrics revealed that plasma treatment can help remove sizing materials and impurities. Chemical and morphological changes in plasma treated samples were analysed by FTIR and SEM, respectively. Finally, dyeability of the plasma treated and conventional wet treated grey cotton fabrics was compared and the results showed that similar dyeing results were obtained. This can prove that plasma treatment would be another choice for treating grey cotton fabrics. Copyright © 2013 Elsevier Ltd. All rights reserved.

  20. Association between the miRNA signatures in plasma and bronchoalveolar fluid in respiratory pathologies.

    PubMed

    Molina-Pinelo, Sonia; Suárez, Rocío; Pastor, María Dolores; Nogal, Ana; Márquez-Martín, Eduardo; Martín-Juan, José; Carnero, Amancio; Paz-Ares, Luis

    2012-01-01

    The identification of new less invasive biomarkers is necessary to improve the detection and prognostic outcome of respiratory pathological processes. The measurement of miRNA expression through less invasive techniques such as plasma and serum have been suggested to analysis of several lung malignancies including lung cancer. These studies are assuming a common deregulated miRNA expression both in blood and lung tissue. The present study aimed to obtain miRNA representative signatures both in plasma and bronchoalveolar cell fraction that could serve as biomarker in respiratory diseases. Ten patients were evaluated to assess the expression levels of 381 miRNAs. We found that around 50% miRNAs were no detected in both plasma and bronchoalveolar cell fraction and only 20% of miRNAs showed similar expression in both samples. These results show a lack of association of miRNA signatures between plasma and bronchoalveolar cytology in the same patient. The profiles are not comparable; however, there is a similarity in the relative expression in a very small subset of miRNAs (miR-17, miR-19b, miR-195 and miR-20b) between both biological samples in all patients. This finding supports that the miRNAs profiles obtained from different biological samples have to be carefully validated to link with respiratory diseases.

  1. Phenolic and microbial-targeted metabolomics to discovering and evaluating wine intake biomarkers in human urine and plasma.

    PubMed

    Urpi-Sarda, Mireia; Boto-Ordóñez, María; Queipo-Ortuño, María Isabel; Tulipani, Sara; Corella, Dolores; Estruch, Ramon; Tinahones, Francisco J; Andres-Lacueva, Cristina

    2015-09-01

    The discovery of biomarkers of intake in nutritional epidemiological studies is essential in establishing an association between dietary intake (considering their bioavailability) and diet-related risk factors for diseases. The aim is to study urine and plasma phenolic and microbial profile by targeted metabolomics approach in a wine intervention clinical trial for discovering and evaluating food intake biomarkers. High-risk male volunteers (n = 36) were included in a randomized, crossover intervention clinical trial. After a washout period, subjects received red wine or gin, or dealcoholized red wine over four weeks. Fasting plasma and 24-h urine were collected at baseline and after each intervention period. A targeted metabolomic analysis of 70 host and microbial phenolic metabolites was performed using ultra performance liquid chromatography-tandem mass spectrometer (UPLC-MS/MS). Metabolites were subjected to stepwise logistic regression to establish prediction models and received operation curves were performed to evaluate biomarkers. Prediction models based mainly on gallic acid metabolites, obtained sensitivity, specificity and area under the curve (AUC) for the training and validation sets of between 91 and 98% for urine and between 74 and 91% for plasma. Resveratrol, ethylgallate and gallic acid metabolite groups in urine samples also resulted in being good predictors of wine intake (AUC>87%). However, lower values for metabolites were obtained in plasma samples. The highest correlations between fasting plasma and urine were obtained for the prediction model score (r = 0.6, P<0.001), followed by gallic acid metabolites (r = 0.5-0.6, P<0.001). This study provides new insights into the discovery of food biomarkers in different biological samples. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  2. Endothelial Inflammatory Transcriptional Responses Induced by Plasma Following Inhalation of Diesel Emissions

    PubMed Central

    Schisler, Jonathan C.; Ronnebaum, Sarah M.; Madden, Michael; Channell, Meghan M.; Campen, Matthew J.; Willis, Monte S.

    2016-01-01

    Background Air pollution, especially emissions derived from traffic sources, is associated with adverse cardiovascular outcomes. However, it remains unclear how inhaled factors drive extrapulmonary pathology. Objectives Previously, we found that canonical inflammatory response transcripts were elevated in cultured endothelial cells treated with plasma obtained after exposure compared with pre-exposure samples or filtered air (sham) exposures. While the findings confirmed the presence of bioactive factor(s) in the plasma after diesel inhalation, we wanted to better examine the complete genomic response to investigate 1) major responsive transcripts and 2) collected response pathways and ontogeny that may help to refine this method and inform the pathogenesis. Methods We assayed endothelial RNA with gene expression microarrays, examining the responses of cultured endothelial cells to plasma obtained from 6 healthy human subjects exposed to 100 μg/m3 diesel exhaust or filtered air for 2 h on separate occasions. In addition to pre-exposure baseline samples, we investigated samples obtained immediately-post and 24h-post exposure. Results Microarray analysis of the coronary artery endothelial cells challenged with plasma identified 855 probes that changed over time following diesel exhaust exposure. Over-representation analysis identified inflammatory cytokine pathways were upregulated both at the 2 and 24 h condition. Novel pathways related to FOX transcription factors and secreted extracellular factors were also identified in the microarray analysis. Conclusions These outcomes are consistent with our recent findings that plasma contains bioactive and inflammatory factors following pollutant inhalation. The specific study design implicates a novel pathway related to inflammatory blood borne components that may drive the extrapulmonary toxicity of ambient air pollutants. PMID:25942053

  3. Development of a Dual Plasma Desorption/Ionization System for the Noncontact and Highly Sensitive Analysis of Surface Adhesive Compounds

    PubMed Central

    Aida, Mari; Iwai, Takahiro; Okamoto, Yuki; Kohno, Satoshi; Kakegawa, Ken; Miyahara, Hidekazu; Seto, Yasuo; Okino, Akitoshi

    2017-01-01

    We developed a dual plasma desorption/ionization system using two plasmas for the semi-invasive analysis of compounds on heat-sensitive substrates such as skin. The first plasma was used for the desorption of the surface compounds, whereas the second was used for the ionization of the desorbed compounds. Using the two plasmas, each process can be optimized individually. A successful analysis of phenyl salicylate and 2-isopropylpyridine was achieved using the developed system. Furthermore, we showed that it was possible to detect the mass signals derived from a sample even at a distance 50 times greater than the distance from the position at which the samples were detached. In addition, to increase the intensity of the mass signal, 0%–0.02% (v/v) of hydrogen gas was added to the base gas generated in the ionizing plasma. We found that by optimizing the gas flow rate through the addition of a small amount of hydrogen gas, it was possible to obtain the intensity of the mass signal that was 45–824 times greater than that obtained without the addition of hydrogen gas. PMID:29234573

  4. Determination of amantadine in biological fluids using simultaneous derivatization and dispersive liquid-liquid microextraction followed by gas chromatography-flame ionization detection.

    PubMed

    Farajzadeh, Mir Ali; Nouri, Nina; Alizadeh Nabil, Ali Akbar

    2013-12-01

    A one-step derivatization and microextraction technique for the determination of amantadine in the human plasma and urine samples is presented. An appropriate mixture of methanol (disperser solvent), 1,2-dibromoethane (extraction solvent), and butylchloroformate (derivatization agent) is rapidly injected into samples. After centrifuging, the sedimented phase is analyzed by gas chromatography-flame ionization detection (GC-FID). The kind of extraction and disperser solvents and their volumes, amount of derivatization agent and reaction/extraction time which are effective in derivatization/dispersive liquid-liquid microextraction (DLLME) procedure are optimized. Under the optimal conditions, the enrichment factor (EF) of the target analyte was obtained to be 408 and 420, and limit of detection (LOD) 4.2 and 2.7ngmL(-1), in plasma and urine respectively. The linear range is 14-5000 and 8.7-5000ng/mL for plasma and urine, respectively (squared correlation coefficient≥0.990). The relative recoveries obtained for the spiked plasma and urine samples are between 72% and 93%. Moreover, the inter- and intra-day precisions are acceptable at all spiked concentrations (relative standard deviation <7%). Finally the method was successfully applied to determine amantadine in biological samples. Copyright © 2013 Elsevier B.V. All rights reserved.

  5. Gunshot residue (GSR) analysis by single particle inductively coupled plasma mass spectrometry (spICP-MS).

    PubMed

    Heringer, Rodrigo D; Ranville, James F

    2018-05-25

    Single particle inductively coupled plasma mass spectrometry (spICP-MS) was investigated as a screening-level technique for the analysis and characterization of inorganic gunshot residue (IGSR) nanoparticles. spICP-MS works with undigested samples whereby nanoparticles (NPs) in a suspension are individually atomized and ionized as they reach the plasma, each resulting in a pulse of analyte ions that can be quantified. The method is rapid, and signals from hundreds of NPs can be collected in 1-2min per sample. The technique is quantitative for NP mass and number concentration when only one element (single element mode) is measured using a quadrupole MS. Likewise, a qualitative elemental fingerprint can be obtained for individual NPs when peak-hopping between two elements (dual element mode). For this proof of concept study, each shooter's hand was sampled with ultrapure water or swab to obtain NPs suspensions. Measurements of antimony, barium, and lead were performed using both analysis modes. With no sample preparation and fully automated sample introduction, it is possible to analyze more than 100 samples in a day. Results show that this technique opens a new perspective for future research on GSR sample identification and characterization and can complement SEM/EDX analysis. Copyright © 2018 Elsevier B.V. All rights reserved.

  6. System of Mueller-Jones matrix polarizing mapping of blood plasma films in breast pathology

    NASA Astrophysics Data System (ADS)

    Zabolotna, Natalia I.; Radchenko, Kostiantyn O.; Tarnovskiy, Mykola H.

    2017-08-01

    The combined method of Jones-Mueller matrix mapping and blood plasma films analysis based on the system that proposed in this paper. Based on the obtained data about the structure and state of blood plasma samples the diagnostic conclusions can be make about the state of breast cancer patients ("normal" or "pathology"). Then, by using the statistical analysis obtain statistical and correlational moments for every coordinate distributions; these indicators are served as diagnostic criterias. The final step is to comparing results and choosing the most effective diagnostic indicators. The paper presents the results of Mueller-Jones matrix mapping of optically thin (attenuation coefficient ,τ≤0,1) blood plasma layers.

  7. The characterization of exosome from blood plasma of patients with colorectal cancer

    NASA Astrophysics Data System (ADS)

    Yunusova, N. V.; Tamkovich, S. N.; Stakheeva, M. N.; Afanas'ev, S. G.; Frolova, A. Y.; Kondakova, I. V.

    2016-08-01

    Exosomes are extracellular membrane structures involved in many physiological and pathological processes including cancerogenesis and metastasis. The clarification of the criteria for exosome isolating and identifying is the purpose of this study. Exosome samples from the plasma of patients with colorectal cancer and healthy donors were examined using transmission electron microscopy and flow cytometry in accordance with the minimum requirements of "International Society for Extracellular Vesicles". The choice of the method for isolation of exosomes from the blood plasma by ultrafiltration and ultracentrifugation allowed obtaining highly purified samples of exosomes, in which all the structural components were clearly seen. The results obtained with flow cytometry suggest that exosomes of blood plasma from patients with colorectal cancer can be produced by epithelial cells. Moreover, cells produce different types of exosomes, which correspond to different mechanisms in sorting macromolecules in the membrane of multivesicular bodies. Determination of significant differences in the expression of specific exosomal proteins from colorectal cancer patients compared to healthy donors suggests a high diagnostic potential significance of circulating exosomes.

  8. Bragg x-ray optics for imaging spectroscopy of plasma microsources.

    PubMed

    Pikuz, T A; Ya Faenov, A; Pikuz, S A; Romanova, V M; Shelkovenko, T A

    1995-01-01

    Bragg x-ray optics based on crystals with transmission and reflection properties bent on cylindrical or spherical surfaces are discussed. Applications of such optics for obtaining one- and two-dimensional monochromatic images of different plasma sources in the wide spectral range 1-20 Å are described. Samples of spectra obtained with spectral resolution of up to λ/Δλ ~ 10,000 and spatial resolution of up to 18 μm are presented.

  9. A random sampling approach for robust estimation of tissue-to-plasma ratio from extremely sparse data.

    PubMed

    Chu, Hui-May; Ette, Ene I

    2005-09-02

    his study was performed to develop a new nonparametric approach for the estimation of robust tissue-to-plasma ratio from extremely sparsely sampled paired data (ie, one sample each from plasma and tissue per subject). Tissue-to-plasma ratio was estimated from paired/unpaired experimental data using independent time points approach, area under the curve (AUC) values calculated with the naïve data averaging approach, and AUC values calculated using sampling based approaches (eg, the pseudoprofile-based bootstrap [PpbB] approach and the random sampling approach [our proposed approach]). The random sampling approach involves the use of a 2-phase algorithm. The convergence of the sampling/resampling approaches was investigated, as well as the robustness of the estimates produced by different approaches. To evaluate the latter, new data sets were generated by introducing outlier(s) into the real data set. One to 2 concentration values were inflated by 10% to 40% from their original values to produce the outliers. Tissue-to-plasma ratios computed using the independent time points approach varied between 0 and 50 across time points. The ratio obtained from AUC values acquired using the naive data averaging approach was not associated with any measure of uncertainty or variability. Calculating the ratio without regard to pairing yielded poorer estimates. The random sampling and pseudoprofile-based bootstrap approaches yielded tissue-to-plasma ratios with uncertainty and variability. However, the random sampling approach, because of the 2-phase nature of its algorithm, yielded more robust estimates and required fewer replications. Therefore, a 2-phase random sampling approach is proposed for the robust estimation of tissue-to-plasma ratio from extremely sparsely sampled data.

  10. Method validation and determinations of levofloxacin, metronidazole and sulfamethoxazole in an aqueous pharmaceutical, urine and blood plasma samples using quantitative nuclear magnetic resonance spectrometry.

    PubMed

    Salem, Alaa A; Mossa, Hussein A

    2012-01-15

    Selective, rapid and accurate quantitative proton nuclear magnetic resonance (qHNMR) method for the determination of levofloxacin, metronidazole benzoate and sulfamethoxazole in aqueous solutions was developed and validated. The method was successfully applied to the determinations of the drugs and their admixtures in pharmaceutical, urine and plasma samples. Maleic acid and sodium malate were used as internal standards. Effect of temperature on spectral measurements was evaluated. Linear dynamic ranges of 0.50-68.00, 0.13-11.30 and 0.24-21.00 mg per 0.60 mL solution were obtained for levofloxacin, metronidazole benzoate and sulfamethoxazole, respectively. Average recovery % in the range of 96.00-104.20 ± (0.17-2.91) was obtained for drugs in pure, pharmaceutical, plasma and urine samples. Inter and intra-day analyses gave average recoveries % in the ranges 96.10-98.40 ± (1.68-2.81) and 96.00-104.20 ± (0.17-2.91), respectively. Instrumental detection limits ≤0.03 mg per 0.6 mL were obtained for the three drugs. Developed method has demonstrated high performance characteristics for analyzing investigated drugs and their admixtures. Student t-test at 95% confidence level revealed insignificant bias between the real and measured contents of investigated drugs in pure, pharmaceutical, urine and plasma samples and its admixtures. Application of the statistical F-test revealed insignificant differences in precisions between the developed method and arbitrary selected reference methods. Copyright © 2011 Elsevier B.V. All rights reserved.

  11. Estimation of reference intervals from small samples: an example using canine plasma creatinine.

    PubMed

    Geffré, A; Braun, J P; Trumel, C; Concordet, D

    2009-12-01

    According to international recommendations, reference intervals should be determined from at least 120 reference individuals, which often are impossible to achieve in veterinary clinical pathology, especially for wild animals. When only a small number of reference subjects is available, the possible bias cannot be known and the normality of the distribution cannot be evaluated. A comparison of reference intervals estimated by different methods could be helpful. The purpose of this study was to compare reference limits determined from a large set of canine plasma creatinine reference values, and large subsets of this data, with estimates obtained from small samples selected randomly. Twenty sets each of 120 and 27 samples were randomly selected from a set of 1439 plasma creatinine results obtained from healthy dogs in another study. Reference intervals for the whole sample and for the large samples were determined by a nonparametric method. The estimated reference limits for the small samples were minimum and maximum, mean +/- 2 SD of native and Box-Cox-transformed values, 2.5th and 97.5th percentiles by a robust method on native and Box-Cox-transformed values, and estimates from diagrams of cumulative distribution functions. The whole sample had a heavily skewed distribution, which approached Gaussian after Box-Cox transformation. The reference limits estimated from small samples were highly variable. The closest estimates to the 1439-result reference interval for 27-result subsamples were obtained by both parametric and robust methods after Box-Cox transformation but were grossly erroneous in some cases. For small samples, it is recommended that all values be reported graphically in a dot plot or histogram and that estimates of the reference limits be compared using different methods.

  12. The Use of Dried Blood Spots for Pharmacokinetic Monitoring of Vemurafenib Treatment in Melanoma Patients.

    PubMed

    Nijenhuis, Cynthia M; Huitema, Alwin D R; Marchetti, Serena; Blank, Christian; Haanen, John B A G; van Thienen, Johannes V; Rosing, Hilde; Schellens, Jan H M; Beijnen, Jos H

    2016-10-01

    Pharmacokinetic monitoring is increasingly becoming an important part of clinical care of tyrosine kinase inhibitor treatment. Vemurafenib is an oral tyrosine kinase inhibitor that inhibits mutated serine/threonine protein kinase B-Raf (BRAF) and is approved for the treatment of adult patients with BRAF V600 mutation-positive unresectable or metastatic melanoma. The aim of this study was to establish the relationship between dried blood spot (DBS) and plasma concentrations of vemurafenib to enable the use of DBS sampling, which is a minimally invasive form of sample collection. In total, 43 paired plasma and DBS samples (in duplicate) were obtained from 8 melanoma patients on vemurafenib therapy and were analyzed using high-performance liquid chromatography-tandem mass spectrometry. Plasma concentrations were predicted from the DBS concentrations using 2 methods: (1) individual hematocrit correction and blood cell-to-plasma partitioning and (2) the calculated slope explaining the relationship between DBS and plasma concentrations (without individual hematocrit correction). Vemurafenib DBS concentrations and plasma concentrations showed a strong correlation (r = 0.964), and the relationship could be described by ([vemurafenib]plasma = [vemurafenib]DBS /0.64). The predicted plasma concentrations were within ±20% of the analyzed plasma concentrations in 97% and 100% of the samples for the methods with and without hematocrit correction, respectively. In conclusion, DBS concentrations and plasma concentrations of vemurafenib are highly correlated. Plasma concentrations can be predicted from DBS concentration using the blood cell-to-plasma partition and the average hematocrit value of this cohort (0.40 L/L). DBS sampling for pharmacokinetic monitoring of vemurafenib treatment can be used in clinical practice. © 2016, The American College of Clinical Pharmacology.

  13. Protocol for obtaining platelet-rich plasma (PRP), platelet-poor plasma (PPP), and thrombin for autologous use.

    PubMed

    Franco, Diogo; Franco, Talita; Schettino, Angélica Maria; Filho, João Medeiros Tavares; Vendramin, Fabiel Spani

    2012-10-01

    Plasma has been widely studied and used in many different situations to speed up healing with better tissue adherence and hemostasis. Research projects are now attempting to isolate platelet-rich plasma (PRP) and platelet-poor plasma (PPP), making better use of their properties, particularly during operations and for wounds that are slow to heal. In view of the wide diversity of industrial machines and extraction protocols, together with the variety of industrially produced biologic glues, this article suggests an option for obtaining PRP, PPP, and human thrombin for autologous use. A way of obtaining PRP, PPP, and thrombin is reproduced through a protocol defined and established by the authors. Autologous thrombin and plasma were obtained through the collection and successive centrifugation of ten whole blood samples, until the desired hemocomponents were isolated, followed by quantitative and qualitative analyses of the elements obtained. The mean platelet concentration obtained was 6.03 × 10(8) platelets/ml, with a mean thrombin concentration of 33.54 nM, both values compatible with reports in the literature when different protocols are applied. The protocol described is a good option for the preparation and application of PRP, PPP, and autologous thrombin, particularly as they can be obtained simultaneously, eliminating the possibilities of viral contamination and allergic reactions. Moreover, the cost of this procedure is low, it is easy to perform, and replicable. This journal requires that authors assign a level of evidence to each article.

  14. Tissue-type plasminogen activator-induced fibrinolysis is enhanced in patients with breast, lung, pancreas and colon cancer.

    PubMed

    Nielsen, Vance G; Matika, Ryan W; Ley, Michele L B; Waer, Amy L; Gharagozloo, Farid; Kim, Samuel; Nfonsam, Valentine N; Ong, Evan S; Jie, Tun; Warneke, James A; Steinbrenner, Evangelina B

    2014-04-01

    Although cancer-mediated changes in hemostatic proteins unquestionably promote hypercoagulation, the effects of neoplasia on fibrinolysis in the circulation are less well defined. The goals of the present investigation were to determine if plasma obtained from patients with breast, lung, pancreas and colon cancer was less or more susceptible to lysis by tissue-type plasminogen activator (tPA) compared to plasma obtained from normal individuals. Archived plasma obtained from patients with breast (n = 18), colon/pancreas (n = 27) or lung (n = 19) was compared to normal individual plasma (n = 30) using a thrombelastographic assay that assessed fibrinolytic vulnerability to exogenously added tPA. Plasma samples were activated with tissue factor/celite, had tPA added, and had data collected until clot lysis occurred. Additional, similar samples had potato carboxypeptidase inhibitor added to assess the role played by thrombin-activatable fibrinolysis inhibitor in cancer-modulated fibrinolysis. Rather than inflicting a hypofibrinolytic state, the three groups of cancers demonstrated increased vulnerability to tPA (e.g. decreased time to lysis, increased speed of lysis, decreased clot lysis time). However, hypercoagulation manifested as increased speed of clot formation and strength compensated for enhanced fibrinolytic vulnerability, resulting in a clot residence time that was not different from normal individual thrombi. In sum, enhanced hypercoagulability associated with cancer was in part diminished by enhanced fibrinolytic vulnerability to tPA.

  15. Multiplex picodroplet digital PCR to detect KRAS mutations in circulating DNA from the plasma of colorectal cancer patients.

    PubMed

    Taly, Valerie; Pekin, Deniz; Benhaim, Leonor; Kotsopoulos, Steve K; Le Corre, Delphine; Li, Xinyu; Atochin, Ivan; Link, Darren R; Griffiths, Andrew D; Pallier, Karine; Blons, Hélène; Bouché, Olivier; Landi, Bruno; Hutchison, J Brian; Laurent-Puig, Pierre

    2013-12-01

    Multiplex digital PCR (dPCR) enables noninvasive and sensitive detection of circulating tumor DNA with performance unachievable by current molecular-detection approaches. Furthermore, picodroplet dPCR facilitates simultaneous screening for multiple mutations from the same sample. We investigated the utility of multiplex dPCR to screen for the 7 most common mutations in codons 12 and 13 of the KRAS (Kirsten rat sarcoma viral oncogene homolog) oncogene from plasma samples of patients with metastatic colorectal cancer. Fifty plasma samples were tested from patients for whom the primary tumor biopsy tissue DNA had been characterized by quantitative PCR. Tumor characterization revealed that 19 patient tumors had KRAS mutations. Multiplex dPCR analysis of the plasma DNA prepared from these samples identified 14 samples that matched the mutation identified in the tumor, 1 sample contained a different KRAS mutation, and 4 samples had no detectable mutation. Among the tumor samples that were wild type for KRAS, 2 KRAS mutations were identified in the corresponding plasma samples. Duplex dPCR (i.e., wild-type and single-mutation assay) was also used to analyze plasma samples from patients with KRAS-mutated tumors and 5 samples expected to contain the BRAF (v-raf murine sarcoma viral oncogene homolog B) V600E mutation. The results for the duplex analysis matched those for the multiplex analysis for KRAS-mutated samples and, owing to its higher sensitivity, enabled detection of 2 additional samples with low levels of KRAS-mutated DNA. All 5 samples with BRAF mutations were detected. This work demonstrates the clinical utility of multiplex dPCR to screen for multiple mutations simultaneously with a sensitivity sufficient to detect mutations in circulating DNA obtained by noninvasive blood collection.

  16. Silica nanoparticles produced by DC arc plasma from a solid raw materials

    NASA Astrophysics Data System (ADS)

    Kosmachev, P. V.; Vlasov, V. A.; Skripnikova, N. K.

    2017-05-01

    Plasma synthesis of SiO2 nanoparticles in experimental atmospheric pressure plasma reactor on the basis of DC arc plasma generator was presented in this paper. Solid high-silica raw materials such as diatomite from Kamyshlovskoye deposit in Russia, quartzite from Chupinskoye deposit in Russia and milled window glass were used. The obtained nanoparticles were characterized based on their morphology, chemical composition and size distribution. Scanning electron microscopy, laser diffractometry, nitrogen absorption (Brunauer-Emmett-Teller method), X-ray photoelectron spectroscopy and energy-dispersive X-ray spectroscopy were used to characterize the synthesized products. The obtained silica nanoparticles are agglomerated, have spherical shape and primary diameters between 10-300 nm. All samples of synthesized nanopowders were compared with commercial nanopowders.

  17. Automation of preparation of nonmetallic samples for analysis by atomic absorption and inductively coupled plasma spectrometry

    NASA Technical Reports Server (NTRS)

    Wittmann, A.; Willay, G.

    1986-01-01

    For a rapid preparation of solutions intended for analysis by inductively coupled plasma emission spectrometry or atomic absorption spectrometry, an automatic device called Plasmasol was developed. This apparatus used the property of nonwettability of glassy C to fuse the sample in an appropriate flux. The sample-flux mixture is placed in a composite crucible, then heated at high temperature, swirled until full dissolution is achieved, and then poured into a water-filled beaker. After acid addition, dissolution of the melt, and filling to the mark, the solution is ready for analysis. The analytical results obtained, either for oxide samples or for prereduced iron ores show that the solutions prepared with this device are undistinguished from those obtained by manual dissolutions done by acid digestion or by high temperature fusion. Preparation reproducibility and analytical tests illustrate the performance of Plasmasol.

  18. Association between the miRNA Signatures in Plasma and Bronchoalveolar Fluid in Respiratory Pathologies

    PubMed Central

    Molina-Pinelo, Sonia; Suárez, Rocío; Pastor, María Dolores; Nogal, Ana; Márquez-Martín, Eduardo; Martín-Juan, José; Carnero, Amancio; Paz-Ares, Luis

    2012-01-01

    The identification of new less invasive biomarkers is necessary to improve the detection and prognostic outcome of respiratory pathological processes. The measurement of miRNA expression through less invasive techniques such as plasma and serum have been suggested to analysis of several lung malignancies including lung cancer. These studies are assuming a common deregulated miRNA expression both in blood and lung tissue. The present study aimed to obtain miRNA representative signatures both in plasma and bronchoalveolar cell fraction that could serve as biomarker in respiratory diseases. Ten patients were evaluated to assess the expression levels of 381 miRNAs. We found that around 50% miRNAs were no detected in both plasma and bronchoalveolar cell fraction and only 20% of miRNAs showed similar expression in both samples. These results show a lack of association of miRNA signatures between plasma and bronchoalveolar cytology in the same patient. The profiles are not comparable; however, there is a similarity in the relative expression in a very small subset of miRNAs (miR-17, miR-19b, miR-195 and miR-20b) between both biological samples in all patients. This finding supports that the miRNAs profiles obtained from different biological samples have to be carefully validated to link with respiratory diseases. PMID:22430188

  19. Simultaneous determination of atorvastatin and valsartan in human plasma by solid-based disperser liquid-liquid microextraction followed by high-performance liquid chromatography-diode array detection.

    PubMed

    Farajzadeh, Mir Ali; Khorram, Parisa; Pazhohan, Azar

    2016-04-01

    A simple, sensitive, and efficient method has been developed for simultaneous estimation of valsartan and atorvastatin in human plasma by combination of solid-based dispersive liquid-liquid microextraction and high performance liquid chromatography-diode array detection. In the proposed method, 1,2-dibromoethane (extraction solvent) is added on a sugar cube (as a solid disperser) and it is introduced into plasma sample containing the analytes. After manual shaking and centrifugation, the resultant sedimented phase is subjected to back extraction into a small volume of sodium hydrogen carbonate solution using air-assisted liquid-liquid microextraction. Then the cloudy solution is centrifuged and the obtained aqueous phase is transferred into a microtube and analyzed by the separation system. Under the optimal conditions, extraction recoveries are obtained in the range of 81-90%. Calibration curves plotted in drug-free plasma sample are linear in the ranges of 5-5000μgL(-1) for valsartan and 10-5000μgL(-1) for atorvastatin with the coefficients of determination higher than 0.997. Limits of detection and quantification of the studied analytes in plasma sample are 0.30-2.6 and 1.0-8.2μgL(-1), respectively. Intra-day (n=6) and inter-days (n=4) precisions of the method are satisfactory with relative standard deviations less than 7.4% (at three levels of 10, 500, and 2000μgL(-1), each analyte). These data suggest that the method can be successfully applied to determine trace amounts of valsartan and atorvastatin in human plasma samples. Copyright © 2016 Elsevier B.V. All rights reserved.

  20. International normalized ratio (INR) testing in Europe: between-laboratory comparability of test results obtained by Quick and Owren reagents.

    PubMed

    Meijer, Piet; Kynde, Karin; van den Besselaar, Antonius M H P; Van Blerk, Marjan; Woods, Timothy A L

    2018-04-12

    This study was designed to obtain an overview of the analytical quality of the prothrombin time, reported as international normalized ratio (INR) and to assess the variation of INR results between European laboratories, the difference between Quick-type and Owren-type methods and the effect of using local INR calibration or not. In addition, we assessed the variation in INR results obtained for a single donation in comparison with a pool of several plasmas. A set of four different lyophilized plasma samples were distributed via national EQA organizations to participating laboratories for INR measurement. Between-laboratory variation was lower in the Owren group than in the Quick group (on average: 6.7% vs. 8.1%, respectively). Differences in the mean INR value between the Owren and Quick group were relatively small (<0.20 INR). Between-laboratory variation was lower after local INR calibration (CV: 6.7% vs. 8.6%). For laboratories performing local calibration, the between-laboratory variation was quite similar for the Owren and Quick group (on average: 6.5% and 6.7%, respectively). Clinically significant differences in INR results (difference in INR>0.5) were observed between different reagents. No systematic significant differences in the between-laboratory variation for a single-plasma sample and a pooled plasma sample were observed. The comparability for laboratories using local calibration of their thromboplastin reagent is better than for laboratories not performing local calibration. Implementing local calibration is strongly recommended for the measurement of INR.

  1. Uric acid is a main electron donor to peroxidases in human blood plasma.

    PubMed

    Padiglia, Alessandra; Medda, Rosaria; Longu, Silvia; Pedersen, Jens Z; Floris, Giovanni

    2002-11-01

    Peroxidases are widely distributed and have been isolated from many higher-order plants, animal tissues, yeast and microorganisms. During measurements of peroxidase activities in samples of human plasma, we noticed the presence of a compound in the plasma which was interfering with the peroxidase assay. In this paper we describe the purification and characterization of this factor, which was identified as uric acid. The procedure used to purify uric acid from plasma involved ultra-filtration of the plasma, heat denaturation, DEAE-cellulose chromatography, and high performance liquid chromatography. The lyophilized powder was tested for homogeneity using an HPLC apparatus and capillary electrophoresis. Genuine uric acid samples were used for comparison. The compound obtained by the above-reported purification procedure was identified as uric acid by spectrophotometric analysis through comparison with genuine uric acid samples. Spectrophotometric measurements indicated that uric acid was degraded by HRP in the presence of H2O2. The experimental procedures described above allowed us to isolate and identify uric acid as the component in human plasma that acts as a true substrate for peroxidases.

  2. Bioanalysis works in the IAA AMS facility: Comparison of AMS analytical method with LSC method in human mass balance study

    NASA Astrophysics Data System (ADS)

    Miyaoka, Teiji; Isono, Yoshimi; Setani, Kaoru; Sakai, Kumiko; Yamada, Ichimaro; Sato, Yoshiaki; Gunji, Shinobu; Matsui, Takao

    2007-06-01

    Institute of Accelerator Analysis Ltd. (IAA) is the first Contract Research Organization in Japan providing Accelerator Mass Spectrometry (AMS) analysis services for carbon dating and bioanalysis works. The 3 MV AMS machines are maintained by validated analysis methods using multiple control compounds. It is confirmed that these AMS systems have reliabilities and sensitivities enough for each objective. The graphitization of samples for bioanalysis is prepared by our own purification lines including the measurement of total carbon content in the sample automatically. In this paper, we present the use of AMS analysis in human mass balance and metabolism profiling studies with IAA 3 MV AMS, comparing results obtained from the same samples with liquid scintillation counting (LSC). Human samples such as plasma, urine and feces were obtained from four healthy volunteers orally administered a 14C-labeled drug Y-700, a novel xanthine oxidase inhibitor, of which radioactivity was about 3 MBq (85 μCi). For AMS measurement, these samples were diluted 100-10,000-fold with pure-water or blank samples. The results indicated that AMS method had a good correlation with LSC method (e.g. plasma: r = 0.998, urine: r = 0.997, feces: r = 0.997), and that the drug recovery in the excreta exceeded 92%. The metabolite profiles of plasma, urine and feces obtained with HPLC-AMS corresponded to radio-HPLC results measured at much higher radioactivity level. These results revealed that AMS analysis at IAA is useful to measure 14C-concentration in bioanalysis studies at very low radioactivity level.

  3. Relationship Between Ebola Virus Real-Time Quantitative Polymerase Chain Reaction-Based Threshold Cycle Value and Virus Isolation From Human Plasma.

    PubMed

    Spengler, Jessica R; McElroy, Anita K; Harmon, Jessica R; Ströher, Ute; Nichol, Stuart T; Spiropoulou, Christina F

    2015-10-01

    We performed a longitudinal analysis of plasma samples obtained from 4 patients with Ebola virus (EBOV) disease (EVD) to determine the relationship between the real-time quantitative reverse transcriptase polymerase chain reaction (qRT-PCR)-based threshold cycle (Ct) value and the presence of infectious EBOV. EBOV was not isolated from plasma samples with a Ct value of >35.5 or >12 days after onset of symptoms. EBOV was not isolated from plasma samples in which anti-EBOV nucleoprotein immunoglobulin G was detected. These data demonstrate the utility of interpreting qRT-PCR results in the context of the course of EBOV infection and associated serological responses for patient-management decisions. Published by Oxford University Press on behalf of the Infectious Diseases Society of America 2015. This work is written by (a) US Government employee(s) and is in the public domain in the US.

  4. Measurement of Clozapine, Norclozapine, and Amisulpride in Plasma and in Oral Fluid Obtained Using 2 Different Sampling Systems.

    PubMed

    Fisher, Danielle S; Beyer, Chad; van Schalkwyk, Gerrit; Seedat, Soraya; Flanagan, Robert J

    2017-04-01

    There is a poor correlation between total concentrations of proton-accepting compounds (most basic drugs) in unstimulated oral fluid and in plasma. The aim of this study was to compare clozapine, norclozapine, and amisulpride concentrations in plasma and in oral fluid collected using commercially available collection devices [Thermo Fisher Scientific Oral-Eze and Greiner Bio-One (GBO)]. Oral-Eze and GBO samples and plasma were collected in that order from patients prescribed clozapine. Analyte concentrations were measured by liquid chromatography-tandem mass spectrometry. There were 112 participants [96 men, aged (median, range) 47 (21-65) years and 16 women, aged 44 (21-65) years]: 74 participants provided 2 sets of samples and 7 provided 3 sets (overall 2 GBO samples not collected). Twenty-three patients were co-prescribed amisulpride, of whom 17 provided 2 sets of samples and 1 provided 3 sets. The median (range) oral fluid within the GBO samples was 52 (13%-86%). Nonadherence to clozapine was identified in all 3 samples in one instance. After correction for oral fluid content, analyte concentrations in the GBO and Oral-Eze samples were poorly correlated with plasma clozapine and norclozapine (R = 0.57-0.63) and plasma amisulpride (R = 0.65-0.72). Analyte concentrations in the 2 sets of oral fluid samples were likewise poorly correlated (R = 0.68-0.84). Mean (SD) plasma clozapine and norclozapine were 0.60 (0.46) and 0.25 (0.21) mg/L, respectively. Mean clozapine and norclozapine concentrations in the 2 sets of oral fluid samples were similar to those in plasma (0.9-1.8 times higher), that is, approximately 2- to 3-fold higher than those in unstimulated oral fluid. The mean (±SD) amisulpride concentrations (microgram per liter) in plasma (446 ± 297) and in the Oral-Eze samples (501 ± 461) were comparable and much higher than those in the GBO samples (233 ± 318). Oral fluid collected using either the GBO system or the Oral-Eze system cannot be used for quantitative clozapine and/or amisulpride therapeutic drug monitoring.

  5. Clinical Validation of Therapeutic Drug Monitoring of Imipenem in Spent Effluent in Critically Ill Patients Receiving Continuous Renal Replacement Therapy: A Pilot Study.

    PubMed

    Wen, Aiping; Li, Zhe; Yu, Junxian; Li, Ren; Cheng, Sheng; Duan, Meili; Bai, Jing

    2016-01-01

    The primary objective of this pilot study was to investigate whether the therapeutic drug monitoring of imipenem could be performed with spent effluent instead of blood sampling collected from critically ill patients under continuous renal replacement therapy. A prospective open-label study was conducted in a real clinical setting. Both blood and effluent samples were collected pairwise before imipenem administration and 0.5, 1, 1.5, 2, 3, 4, 6, and 8 h after imipenem administration. Plasma and effluent imipenem concentrations were determined by reversed-phase high-performance liquid chromatography with ultraviolet detection. Pharmacokinetic and pharmacodynamic parameters of blood and effluent samples were calculated. Eighty-three paired plasma and effluent samples were obtained from 10 patients. The Pearson correlation coefficient of the imipenem concentrations in plasma and effluent was 0.950 (P<0.0001). The average plasma-to-effluent imipenem concentration ratio was 1.044 (95% confidence interval, 0.975 to 1.114) with Bland-Altman analysis. No statistically significant difference was found in the pharmacokinetic and pharmacodynamic parameters tested in paired plasma and effluent samples with Wilcoxon test. Spent effluent of continuous renal replacement therapy could be used for therapeutic drug monitoring of imipenem instead of blood sampling in critically ill patients.

  6. Combined surface hardening and laser patterning approach for functionalising stainless steel surfaces

    NASA Astrophysics Data System (ADS)

    Garcia-Giron, A.; Romano, J. M.; Liang, Y.; Dashtbozorg, B.; Dong, H.; Penchev, P.; Dimov, S. S.

    2018-05-01

    The paper reports a laser patterning method for producing surfaces with dual scale topographies on ferritic stainless steel plates that are hardened by low temperature plasma surface alloying. Nitrogen and carbon based gasses were used in the alloying process to obtain surface layers with an increased hardness from 172 HV to 1001 HV and 305 HV, respectively. Then, a nanosecond infrared laser was used to pattern the plasma treated surfaces and thus to obtain super-hydrophobicity, by creating cell- or channel-like surface structures. The combined surface hardening and laser patterning approach allowed super-hydrophobic surfaces to be produced on both nitrided and carburised stainless steel plates with effective contact angles higher than 150°. The hardened layers on nitrided samples had cracks and was delaminated after the laser patterning while on plasma carburised samples remained intact. The results showed that by applying the proposed combined approach it is possible to retain the higher hardness of the nitrided stainless steel plates and at the same time to functionalise them to obtain super-hydrophobic properties.

  7. Preparation and Application of an Innovative Thrombocyte/Leukocyte-Enriched Plasma to Promote Tissue Repair in Chelonians

    PubMed Central

    Di Ianni, Francesco; Merli, Elisa; Burtini, Francesca; Conti, Virna; Pelizzone, Igor; Di Lecce, Rosanna; Parmigiani, Enrico; Squassino, Gian Paolo; Del Bue, Maurizio; Lucarelli, Enrico; Ramoni, Roberto; Grolli, Stefano

    2015-01-01

    Platelet concentrates are widely used in mammalian regenerative medicine to improve tissue healing. Chelonians (Testudines) would benefit from the application of thrombocyte preparations to regenerate damaged tissues, since traumatic injuries are leading causes of morbidity and mortality for both wild-living and domesticated animals. The aim of this study was to establish a protocol that optimized the recovery of the thrombocytes from blood samples and to show the efficacy of thrombocyte-enriched plasma in chelonians. Peripheral blood samples were obtained from Testudo spp. (n = 12) and Trachemys scripta elegans (n = 10). Blood cells were fractionated by sodium diatrizoate-sodium polysucrose density gradient using a two-step centrifugation protocol. Thrombocytes and leukocytes were isolated and resuspended to obtain thrombocyte-leucocyte rich plasma (TLRP). The mean recovery of leukocytes and thrombocytes was 48.9% (±4.0 SEM, n = 22) of the whole blood cell content. No statistically significant difference was observed between blood samples collected from different turtle species. The ability of TLRP to form a gel was evaluated by adding variable concentrations of calcium gluconate at room temperature and at 37°C. A reliable and consistent clotting of the TLRP was obtained in glass tubes and dishes by adding 5-20% v/v of a 100 mg/ml solution of calcium gluconate. Furthermore, in order to test the clinical efficacy of TLRP, a preliminary evaluation was performed on four turtles (Testudo spp.) with traumatic injuries. In all the four animals, a successful clinical outcome was observed. The results demonstrated that a thrombocyte-enriched plasma, comparable to mammalian platelet rich plasma, can be prepared from chelonian blood samples. Furthermore, although the low number of cases presented does not allow definitive conclusions from a clinical point of view, their outcome suggests that TLRP application could be further investigated to improve the healing process of both soft and hard tissue injuries in chelonians. PMID:25901960

  8. Evaluation of the rapid plasma reagin "teardrop" card test for screening of syphilis in field conditions.

    PubMed

    Van Dyck, E; Van de Velden, L; Ndoye, I; Piot, P; Meheus, A

    1993-01-01

    The availability of simple diagnostic methods may contribute to more efficient control of sexually transmitted diseases (STDs) in developing countries. For the detection of syphilis, a simple rapid plasma reagin (RPR) "teardrop" assay for finger-prick blood samples was developed in 1962. The reliability of this test is compared with RPR, Treponema pallidum hemagglutination assay (TPHA), and fluorescent treponemal antibody absorption (FTA-Abs) assays performed on venous blood samples. To evaluate the potential usefulness of the finger-stick RPR teardrop assay for diagnosis of syphilis in settings with poor medical resources. Pregnant women evaluated at two health centers in Pikine, Senegal were tested for STDs. The RPR teardrop assay was performed on plasma from blood samples obtained by finger prick, and standard RPR, TPHA, and FTA-Abs procedures were performed on serum obtained by vein puncture. The sensitivity and specificity of the finger-prick RPR teardrop assay were 69.7% and 96.5%, respectively, and its reactivity was correlated with RPR serum antibody titer. The finger-prick RPR teardrop assay is not a reliable alternative to the classic serum RPR test.

  9. Three-phase double-arc plasma for spectrochemical analysis of environmental samples.

    PubMed

    Mohamed, M M; Ghatass, Z F; Shalaby, E A; Kotb, M M; El-Raey, M

    2000-12-01

    A new instrument, which uses a three-phase current to support a double-arc argon plasma torch for evaporation, atomization and excitation of solid or powder samples, is described. The sampling arc is ignited between the first and second electrode while the excitation arc is ignited between the second and third electrode. Aerosol generated from the sample (first electrode) is swept by argon gas, through a hole in the second electrode (carbon tubing electrode), into the excitation plasma. A tangential stream of argon gas is introduced through an inlet orifice as a coolant gas for the second electrode. This gas stream forces the excitation arc discharge to rotate reproducibly around the electrode surface. Discharge rotation increases the stability of the excitation plasma. Spectroscopic measurements are made directly in the current-carrying region of the excitation arc. An evaluation of each parameter influencing the device performance was performed. Analytical calibration curves were obtained for Fe, Al, K, and Pb. Finally, the present technique was applied for the analysis of environmental samples. The present method appears to have significant, low cost analytical utility for environmental measurements.

  10. Plasma-induced graft-polymerization of polyethylene glycol acrylate on polypropylene substrates

    NASA Astrophysics Data System (ADS)

    Zanini, S.; Orlandi, M.; Colombo, C.; Grimoldi, E.; Riccardi, C.

    2009-08-01

    A detailed study of argon plasma-induced graft-polymerization of polyethylene glycol acrylate (PEGA) on polypropylene (PP) substrates (membranes and films) is presented. The process consists of four steps: (a) plasma pre-activation of the PP substrates; (b) immersion in a PEGA solution; (c) argon plasma-induced graft-polymerization; (d) washing and drying of the samples. Influence of the solution and plasma parameters on the process efficiency evaluated in terms of amount of grafted polymer, coverage uniformity and substrates wettability, are investigated. The plasma-induced graft-polymerization of PEGA is then followed by sample weighting, water droplet adsorption time and contact angle measurements, attenuated total reflection infrared spectroscopy (ATR-IR), X-ray photoelectron spectroscopy (XPS) and atomic force microscopy (AFM) analyses. The stability of the obtained thin films was evaluated in water and in phosphate buffer saline (PBS) at 37 °C. Results clearly indicates that plasma-induced graft-polymerization of PEGA is a practical methodology for anti-fouling surface modification of materials.

  11. Effect of the conditions of isolation on the physicochemical properties of human serum albumin in the norm and with pathology

    NASA Astrophysics Data System (ADS)

    Ivanov, A. I.; Zhbankov, R. G.; Korolenko, E. A.; Korolik, E. V.; Meleshchenko, L. A.; Sarnatskaya, V. V.; Nikolaev, V. G.; Nikolaichik, V. V.; Yushko, L. A.

    1997-01-01

    Differential scanning calorimetry and IR spectrosocopy were used to investigate the effect of the procedure of isolation of human serum albumin on its physicochemical characteristics. It is shown that fractionation of blood plasma with ethylene glycol followed by ion exchange chromatography can be used to obtain albumin of normal donors that is similar to the albumin in the nonfractionated plasma according to melting thermograms. Endotherms of human serum albumin samples that were obtained by affinity chromatography and preparative electrophoresis are bimodal, unlike the monophasic for albumin obtained by polyethylene glycol precipitation. These changes result from a higher content of nonetherified fatty acids in the albumin samples obtained by affinity chromatography and from modification of the secondary protein structure in the samples obtained by electrophoresis. Analysis of melting thermograms of serum albumin from patients with uremia, chronic hepatitis, and peritonitis shows that fractionation of blood with polyethylene glycol preserves the thermodynamic characteristics of the various pathological serum albumins to the greatest extent. The present results demonstrate the advantage of polyethylene glycol fractionation for isolation of native preparations of normal and “pathological” human serum albumin.

  12. The characterization of exosome from blood plasma of patients with colorectal cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yunusova, N. V., E-mail: Bochkarevanv@oncology.tomsk.ru; Siberian State Medical University, Moskovsky Trakt 2, Tomsk, 634050; Tamkovich, S. N., E-mail: s.tamk@niboch.nsc.ru

    Exosomes are extracellular membrane structures involved in many physiological and pathological processes including cancerogenesis and metastasis. The clarification of the criteria for exosome isolating and identifying is the purpose of this study. Exosome samples from the plasma of patients with colorectal cancer and healthy donors were examined using transmission electron microscopy and flow cytometry in accordance with the minimum requirements of “International Society for Extracellular Vesicles”. The choice of the method for isolation of exosomes from the blood plasma by ultrafiltration and ultracentrifugation allowed obtaining highly purified samples of exosomes, in which all the structural components were clearly seen. Themore » results obtained with flow cytometry suggest that exosomes of blood plasma from patients with colorectal cancer can be produced by epithelial cells. Moreover, cells produce different types of exosomes, which correspond to different mechanisms in sorting macromolecules in the membrane of multivesicular bodies. Determination of significant differences in the expression of specific exosomal proteins from colorectal cancer patients compared to healthy donors suggests a high diagnostic potential significance of circulating exosomes.« less

  13. Determination of major elements by wavelength-dispersive X-ray fluorescence spectrometry and trace elements by inductively coupled plasma mass spectrometry in igneous rocks from the same fused sample (110 mg)

    NASA Astrophysics Data System (ADS)

    Amosova, Alena A.; Panteeva, Svetlana V.; Chubarov, Victor M.; Finkelshtein, Alexandr L.

    2016-08-01

    The fusion technique is proposed for simultaneous determination of 35 elements from the same sample. Only 110 mg of rock sample was used to obtain fused glasses for quantitative determination of 10 major elements by wavelength dispersive X-ray fluorescence analysis, 16 rare earth elements and some other trace elements by inductively coupled plasma mass spectrometry analysis. Fusion was performed with 1.1 g of lithium metaborate and LiBr solution as the releasing agent in platinum crucible in electric furnace at 1100 °C. The certified reference materials of ultramafic, mafic, intermediate and felsic igneous rocks have been applied to obtain the calibration curves for rock-forming oxides (Na2O, MgO, Al2O3, SiO2, P2O5, K2O, CaO, TiO2, MnO, Fe2O3) and some trace elements (Ba, Sr, Zr) determination by X-ray fluorescence analysis. The repeatability does not exceed the allowable standard deviation for a wide range of concentrations. In the most cases the relative standard deviation was less than 5%. Obtained glasses were utilized for the further determination of rare earth (La, Ce, Pr, Nd, Sm, Eu, Gd, Tb, Dy, Ho, Er, Tm, Yb, Lu) and some other (Ba, Sr, Zr, Rb, Cs, Y, Nb, Hf, Ta, Th and U) trace elements by inductively coupled plasma mass spectrometry analysis with the same certified reference materials employed. The results could mostly be accepted as satisfactory. The proposed procedure essentially reduces the expenses in comparison with separate sample preparation for inductively coupled plasma mass spectrometry and X-ray fluorescence analysis.

  14. Spectrochemical analysis of powdered biological samples using transversely excited atmospheric carbon dioxide laser plasma excitation

    NASA Astrophysics Data System (ADS)

    Zivkovic, Sanja; Momcilovic, Milos; Staicu, Angela; Mutic, Jelena; Trtica, Milan; Savovic, Jelena

    2017-02-01

    The aim of this study was to develop a simple laser induced breakdown spectroscopy (LIBS) method for quantitative elemental analysis of powdered biological materials based on laboratory prepared calibration samples. The analysis was done using ungated single pulse LIBS in ambient air at atmospheric pressure. Transversely-Excited Atmospheric pressure (TEA) CO2 laser was used as an energy source for plasma generation on samples. The material used for the analysis was a blue-green alga Spirulina, widely used in food and pharmaceutical industries and also in a few biotechnological applications. To demonstrate the analytical potential of this particular LIBS system the obtained spectra were compared to the spectra obtained using a commercial LIBS system based on pulsed Nd:YAG laser. A single sample of known concentration was used to estimate detection limits for Ba, Ca, Fe, Mg, Mn, Si and Sr and compare detection power of these two LIBS systems. TEA CO2 laser based LIBS was also applied for quantitative analysis of the elements in powder Spirulina samples. Analytical curves for Ba, Fe, Mg, Mn and Sr were constructed using laboratory produced matrix-matched calibration samples. Inductively coupled plasma optical emission spectroscopy (ICP-OES) was used as the reference technique for elemental quantification, and reasonably well agreement between ICP and LIBS data was obtained. Results confirm that, in respect to its sensitivity and precision, TEA CO2 laser based LIBS can be successfully applied for quantitative analysis of macro and micro-elements in algal samples. The fact that nearly all classes of materials can be prepared as powders implies that the proposed method could be easily extended to a quantitative analysis of different kinds of materials, organic, biological or inorganic.

  15. Preparation of a bonelike apatite-polymer fiber composite using a simple biomimetic process.

    PubMed

    Yokoyama, Yoshiro; Oyane, Ayako; Ito, Atsuo

    2008-08-01

    A bonelike apatite-polymer fiber composite may be useful as an implant material to replace bone, the enthesis of a tendon, and the joint part of a ligament. We treated an ethylene-vinyl alcohol copolymer (EVOH) plate and knitted EVOH fibers with an oxygen plasma to produce oxygen-containing functional groups on their surfaces. The plasma-treated samples were alternately dipped in alcoholic calcium and phosphate ion solutions three times to deposit apatite precursors onto their surfaces. The surface-modified samples formed a dense and uniform bonelike surface apatite layer after immersion for 24 h in a simulated body fluid with ion concentrations approximately equal to those of human blood plasma. The adhesive strength between the apatite layer and the sample's surface increased with increasing power density of the oxygen plasma. The apatite-EVOH fiber composite obtained by our process has similarities to natural bone in that apatite crystals are deposited on organic polymer fibers. The resulting composite would possess osteoconductivity due to the apatite phase. With proper polymer selection and optimized synthesis techniques, a composite could be made that would have bonelike mechanical properties. Hence, the present surface modification and coating process would be a promising route to obtain new implant materials with bonelike mechanical properties and osteoconductivity. (c) 2007 Wiley Periodicals, Inc.

  16. Comparative Evaluation of Three Nucleic Acid-Based Assays for BK Virus Quantification

    PubMed Central

    Descamps, Veronique; Martin, Elodie; Morel, Virginie; François, Catherine; Helle, François; Duverlie, Gilles; Castelain, Sandrine

    2015-01-01

    With the growing importance of BK virus (BKV), effective and efficient screening for BKV replication in plasma and urine samples is very important for monitoring renal transplant and hematopoietic stem cell transplant recipients, who are at increased risk of BKV-associated diseases. However, recent assays proposed by many manufacturers have not been tested, and the available tests have not been standardized. The aim of the present study was to evaluate and compare the performances of three commercially available kits, R-gene, GeneProof, and RealStar, on plasma and urine specimens from patients infected with various genotypes and to determine the correlations with the results from a reference laboratory. A qualitatively excellent global agreement (96.8%) was obtained. RealStar PCR tended to give a higher sensitivity, especially for subtype Ib1 samples. Comparison of 30 plasma samples and 53 urine samples showed a good agreement between the three assays, with Spearman's Rho correlation coefficient values falling between 0.92 and 0.98 (P < 0.001). Moreover, a perfect correlation was obtained for comparison of the assay performances with the AcroMetrix BKV panel (P < 0.001 for all comparisons). According to Bland-Altman analysis, more than 95% (240/249 comparisons) of sample comparisons were situated in the range of the mean ± 2 standard deviations (SD). The greatest variability between assays was observed for 10.2% of subtype Ib2 samples, with differences of >1 log10 copies/ml. In conclusion, this study demonstrated the reliable and comparable performances of the R-gene, GeneProof, and RealStar real-time PCR systems for quantification of BKV in urine and plasma samples. All three real-time PCR assays are appropriate for screening of BKV replication in patients. PMID:26424842

  17. Using the developed cross-flow filtration chip for collecting blood plasma under high flow rate condition and applying the immunoglobulin E detection

    NASA Astrophysics Data System (ADS)

    Yeh, Chia-Hsien; Hung, Chia-Wei; Wu, Chun-Han; Lin, Yu-Cheng

    2014-09-01

    This paper presents a cross-flow filtration chip for separating blood cells (white blood cells, red blood cells, and platelets) and obtaining blood plasma from human blood. Our strategy is to flow the sample solution in parallel to the membrane, which can generate a parallel shear stress to remove the clogging microparticles on the membrane, so the pure sample solution is obtained in the reservoir. The cross-flow filtration chip includes a cross-flow layer, a Ni-Pd alloy micro-porous membrane, and a reservoir layer. The three layers are packaged in a polymethylmethacrylate (PMMA) frame to create the cross-flow filtration chip. Various dilutions of the blood sample (original, 2 × , 3 × , 5 × , and 10×), pore sizes with different diameters (1 µm, 2 µm, 4 µm, 7 µm, and 10 µm), and different flow rates (1 mL/min, 3 mL/min, 5 mL/min, 7 mL/min, and 10 mL/min) are tested to determine their effects on filtration percentage. The best filtration percentage is 96.2% when the dilution of the blood sample is 10 × , the diameter of pore size of a Ni-Pd alloy micro-porous membrane is 2 µm, and the flow rate is 10 mL/min. Finally, for the clinical tests of the immunoglobulin E (IgE) concentration, the cross-flow filtration chip is used to filter the blood of the allergy patients to obtain the blood plasma. This filtered blood plasma is compared with that obtained using the conventional centrifugation based on the enzyme-linked immunosorbent assay. The results reveal that these two blood separation methods have similar detection trends. The proposed filtration chip has the advantages of low cost, short filtration time, and easy operation and thus can be applied to the separation of microparticles, cells, bacteria, and blood.

  18. Assay of free captopril in human plasma as monobromobimane derivative, using RPLC/(+)ESI/MS/MS: validation aspects and bioequivalence evaluation.

    PubMed

    Medvedovici, Andrei; Albu, Florin; Sora, Iuliana Daniela; Udrescu, Stefan; Galaon, Toma; David, Victor

    2009-10-01

    A sensitive method for determination of free captopril as monobromobimane derivative in plasma samples is discussed. The internal standard (IS) was 5-methoxy-1H-benzimidazole-2-thiol. Derivatization with monobromobimane immediately after blood collection and plasma preparation prevents oxidation of captopril to the corresponding disulfide compound and enhances the ionization yield. Consequently, derivatization enhances sample stability and detection sensitivity. Addition of the internal standard was made immediately after plasma preparation. The internal standard was also derivatized by monobromobimane, as it contains a thiol functional group. Preparation of plasma samples containing captopril and IS derivatives was based upon protein precipitation through addition of acetonitrile, in a volumetric ratio 1:2. The reversed-phase liquid chromatographic separation was achieved on a rapid resolution cartridge Zorbax SB-C(18), monitored through positive electrospray ionization and tandem MS detection using the multiple-reaction monitoring mode. Transitions were 408-362 amu for the captopril derivative and 371-260 amu for the internal standard derivative. The kinetics of captopril oxidation to the corresponding disulfide compound in plasma matrix was also studied using the proposed method. A linear log-log calibration was obtained over the concentration interval 2.5-750 ng/mL. A low limit of quantitation in the 2.5 ng/mL range was obtained. The analytical method was fully validated and successfully applied in a three-way, three-period, single-dose (50 mg), block-randomized bioequivalence study for two pharmaceutical formulations (captopril LPH 25 and 50 mg) against the comparator Capoten 50 mg. Copyright (c) 2009 John Wiley & Sons, Ltd.

  19. The role of the habenula-interpeduncular pathway in modulating levels of circulating adrenal hormones.

    PubMed

    Murray, M; Murphy, C A; Ross, L L; Haun, F

    1994-01-01

    The fasciculus retroflexus (FR) is the major pathway by which the medial and lateral habenular nuclei project to the interpeduncular nucleus (IPN) and ventral tegmentum. Recent work has suggested that the habenula-interpeduncular system may be involved in the regulation of states of arousal. Bilateral FR lesions have been shown to disrupt chronically, and habenula transplants have been shown to restore normal sleep patterns in rats [J. NeuroscL, 12 (1992) 3282-3290]. In this study, we examined whether FR lesions and habenula cell transplants would also modify chronically the circulating plasma levels of the stress-related hormones, norepinephrine (NE), epinephrine (EPI) and corticosterone. When plasma samples were obtained via retro-orbital eye-bleed during anesthesia, animals with FR lesions had significantly increased levels of plasma NE, EPI and corticosterone 2-3 months postoperatively compared to unoperated controls. Transplants of embryonic habenula cells placed near the denervated IPN in FR-lesioned animals restored levels of NE and EPI to normal, but did not attenuate elevated corticosterone levels. When plasma samples were obtained in conscious animals via indwelling arterial cannulae, FR-lesioned rats likewise exhibited increased basal levels of corticosterone but plasma levels of catecholamines were similar to those of unoperated controls. Differences in our results obtained using the two methods of blood sampling may be explained by the effects of anesthesia and stress associated with the eye-bleed method. Thus, the effect of FR lesions in increasing plasma levels of catecholamines may not reflect a difference in basal hormone levels, but a heightened sympathetic adrenomedullary response to stress. While these results indicate that the integrity of the habenular efferent pathway is important in modulating circulating levels of hormones associated with the stress response, two separate mechanisms appear to control its interactions with sympathetic-adrenal medullary and adrenocortical pathways.

  20. Measured oscillator strengths in singly ionized molybdenum

    NASA Astrophysics Data System (ADS)

    Mayo-García, R.; Aragón, C.; Aguilera, J. A.; Ortiz, M.

    2015-11-01

    In this article, 112 oscillator strengths from Mo II have been measured, 79 of which for the first time. The radiative parameters have been obtained by laser-induced breakdown spectroscopy (LIBS). The plasma is produced from a fused glass sample prepared from molybdenum oxide with a Mo atomic concentration of 0.1%. The plasma evolved in air at atmospheric pressure, and measurements were carried out with the following plasma parameters: an electron density of (2.5+/- 0.1)\\cdot {10}17 cm-3 and an electron temperature of 14,400+/- 200 K. In these conditions, a local thermodynamic equilibrium environment and an optically thin plasma were confirmed for the measurements. The relative intensities were placed on an absolute scale by combining branching fractions with the measured lifetimes and by comparing well-known lines using the plasma temperature. Comparisons were made to previously obtained experimental and theoretical values wherever possible.

  1. Quantitative analysis of titanium concentration using calibration-free laser-induced breakdown spectroscopy (LIBS)

    NASA Astrophysics Data System (ADS)

    Zaitun; Prasetyo, S.; Suliyanti, M. M.; Isnaeni; Herbani, Y.

    2018-03-01

    Laser-induced breakdown spectroscopy (LIBS) can be used for quantitative and qualitative analysis. Calibration-free LIBS (CF-LIBS) is a method to quantitatively analyze concentration of elements in a sample in local thermodynamic equilibrium conditions without using available matrix-matched calibration. In this study, we apply CF-LIBS for quantitative analysis of Ti in TiO2 sample. TiO2 powder sample was mixed with polyvinyl alcohol and formed into pellets. An Nd:YAG pulsed laser at a wavelength of 1064 nm was focused onto the sample to generate plasma. The spectrum of plasma was recorded using spectrophotometer then compared to NIST spectral line to determine energy levels and other parameters. The value of plasma temperature obtained using Boltzmann plot is 8127.29 K and electron density from calculation is 2.49×1016 cm-3. Finally, the concentration of Ti in TiO2 sample from this study is 97% that is in proximity with the sample certificate.

  2. Single clay sheets inside electrospun polymer nanofibers

    NASA Astrophysics Data System (ADS)

    Sun, Zhaohui

    2005-03-01

    Nanofibers were prepared from polymer solution with clay sheets by electrospinning. Plasma etching, as a well controlled process, was used to supply electrically excited gas molecules from a glow discharge. To reveal the structure and arrangement of clay layers in the polymer matrix, plasma etching was used to remove the polymer by controlled gasification to expose the clay sheets due to the difference in reactivity. The shape, flexibility, and orientation of clay sheets were studied by transmission and scanning electron microscopy. Additional quantitative information on size distribution and degree of exfoliation of clay sheets were obtained by analyzing electron micrograph of sample after plasma etching. Samples in various forms including fiber, film and bulk, were thinned by plasma etching. Morphology and dispersion of inorganic fillers were studied by electron microscopy.

  3. Lack of Association between Human Plasma Oxytocin and Interpersonal Trust in a Prisoner’s Dilemma Paradigm

    PubMed Central

    Christensen, James C.; Shiyanov, Pavel A.; Estepp, Justin R.; Schlager, John J.

    2014-01-01

    Expanding interest in oxytocin, particularly the role of endogenous oxytocin in human social behavior, has created a pressing need for replication of results and verification of assay methods. In this study, we sought to replicate and extend previous results correlating plasma oxytocin with trust and trustworthy behavior. As a necessary first step, the two most commonly used commercial assays were compared in human plasma via the addition of a known quantity of exogenous oxytocin, with and without sample extraction. Plasma sample extraction was found to be critical in obtaining repeatable concentrations of oxytocin. In the subsequent trust experiment, twelve samples in duplicate, from each of 82 participants, were collected over approximately six hours during the performance of a Prisoner’s Dilemma task paradigm that stressed human interpersonal trust. We found no significant relationship between plasma oxytocin concentrations and trusting or trustworthy behavior. In light of these findings, previous published work that used oxytocin immunoassays without sample extraction should be reexamined and future research exploring links between endogenous human oxytocin and trust or social behavior should proceed with careful consideration of methods and appropriate biofluids for analysis. PMID:25549255

  4. Micro-NRA and micro-3HIXE with 3He microbeam on samples exposed in ASDEX Upgrade and Pilot-PSI machines

    NASA Astrophysics Data System (ADS)

    Kelemen, Mitja; Založnik, Anže; Vavpetič, Primož; Pečovnik, Matic; Pelicon, Primož; Hakola, Antti; Lahtinen, Aki; Karhunen, Juuso; Piip, Kaarel; Paris, Peeter; Laan, Matti; Krieger, Karl; Oberkofler, Martin; van der Meiden, Hennie; Markelj, Sabina

    2017-08-01

    Micro nuclear reaction analysis (micro-NRA) exploiting the nuclear reaction D(3He,p)4He was used for post-mortem analyses of special marker samples, exposed to deuterium plasma inside ASDEX Upgrade (AUG) tokamak and to the deuterium plasma jet in the Pilot-PSI linear plasma gun. Lateral concentration profiles of deuterium and erosion/deposition profiles of the marker materials were obtained by a combination of micro-NRA and particle induced X-ray emission by 3He beam (3HIXE). In the case of AUG samples, where 25 nm thick W marker layers had been deposited on unpolished and polished graphite substrates, the effect of surface roughness on local erosion and deposition was also investigated. The lateral distribution of W concentration showed that erosion is much more distinct in the case of polished samples and the resulting surface shows a ;leopard; skin pattern of W accumulated on carbon aggregates left on the surface from polishing. The Pilot-PSI samples indicated preferential accumulation of deuterium a few mm off from the centre of the region affected by the plasma beam. This is connected with the largest surface modifications while the thick deposited layers at the centre do not favour deuterium retention per se. The results were cross correlated with those obtained using laser-induced breakdown spectroscopy (LIBS). With its quantitative abilities, micro-NRA provided essential calibration data for in situ LIBS operation, as well as for complementary post mortem Secondary Ion Mass Spectroscopy (SIMS).

  5. Comparison of two blood sampling techniques for the determination of coagulation parameters in the horse: Jugular venipuncture and indwelling intravenous catheter.

    PubMed

    Mackenzie, C J; McGowan, C M; Pinchbeck, G; Carslake, H B

    2018-05-01

    Evaluation of coagulation status is an important component of critical care. Ongoing monitoring of coagulation status in hospitalised horses has previously been via serial venipuncture due to concerns that sampling directly from the intravenous catheter (IVC) may alter the accuracy of the results. Adverse effects such as patient anxiety and trauma to the sampled vessel could be avoided by the use of an indwelling IVC for repeat blood sampling. To compare coagulation parameters from blood obtained by jugular venipuncture with IVC sampling in critically ill horses. Prospective observational study. A single set of paired blood samples were obtained from horses (n = 55) admitted to an intensive care unit by direct jugular venipuncture and, following removal of a presample, via an indwelling IVC. The following coagulation parameters were measured on venipuncture and IVC samples: whole blood prothrombin time (PT), fresh plasma PT and activated partial thromboplastin time (aPTT) and stored plasma antithrombin activity (AT) and fibrinogen concentration. D-dimer concentration was also measured in some horses (n = 22). Comparison of venipuncture and IVC results was performed using Lin's concordance correlation coefficient. Agreement between paired results was assessed using Bland Altman analysis. Correlation was substantial and agreement was good between sample methods for all parameters except AT and D-dimers. Each coagulation parameter was tested using only one assay. Sampling was limited to a convenience sample and timing of sample collection was not standardised in relation to when the catheter was flushed with heparinised saline. With the exception of AT and D-dimers, coagulation parameters measured on blood samples obtained via an IVC have clinically equivalent values to those obtained by jugular venipuncture. © 2017 EVJ Ltd.

  6. Pharmacokinetic Evaluation of Oral Levofloxacin in Human Immunodeficiency Virus-Infected Subjects Receiving Concomitant Antiretroviral Therapy

    PubMed Central

    Villani, P.; Viale, P.; Signorini, L.; Cadeo, B.; Marchetti, F.; Villani, A.; Fiocchi, C.; Regazzi, M. B.; Carosi, G.

    2001-01-01

    The purpose of this study was to evaluate the pharmacokinetics (PK) profile of oral levofloxacin in human immunodeficiency virus-positive patients in steady-state treatment with nelfinavir (NFV) or with efavirenz (EFV) and to determine the effects of levofloxacin on the PK parameters of these two antiretroviral agents. For levofloxacin, plasma samples were obtained at steady state during a 24-h dosing interval. Plasma NFV and EFV concentrations were evaluated before and after 4 days of levofloxacin treatment. Levofloxacin PK do not seem affected by NFV and EFV. There was no significant difference between NFV and EFV plasma levels obtained with and without levofloxacin. PMID:11408245

  7. Uncertainty Measurement for Trace Element Analysis of Uranium and Plutonium Samples by Inductively Coupled Plasma-Atomic Emission Spectrometry (ICP-AES) and Inductively Coupled Plasma-Mass Spectrometry (ICP-MS)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gallimore, David L.

    2012-06-13

    The measurement uncertainty estimatino associated with trace element analysis of impurities in U and Pu was evaluated using the Guide to the Expression of Uncertainty Measurement (GUM). I this evalution the uncertainty sources were identified and standard uncertainties for the components were categorized as either Type A or B. The combined standard uncertainty was calculated and a coverage factor k = 2 was applied to obtain the expanded uncertainty, U. The ICP-AES and ICP-MS methods used were deveoped for the multi-element analysis of U and Pu samples. A typical analytical run consists of standards, process blanks, samples, matrix spiked samples,more » post digestion spiked samples and independent calibration verification standards. The uncertainty estimation was performed on U and Pu samples that have been analyzed previously as part of the U and Pu Sample Exchange Programs. Control chart results and data from the U and Pu metal exchange programs were combined with the GUM into a concentration dependent estimate of the expanded uncertainty. Comparison of trace element uncertainties obtained using this model was compared to those obtained for trace element results as part of the Exchange programs. This process was completed for all trace elements that were determined to be above the detection limit for the U and Pu samples.« less

  8. Human papillomavirus DNA detection in plasma and cervical samples of women with a recent history of low grade or precancerous cervical dysplasia

    PubMed Central

    Sina, Federica; Piana, Andrea; Sotgiu, Giovanni; Dell’Anna, Tiziana; Musumeci, Rosario

    2017-01-01

    Circulating HPV DNA has been previously described in women with advanced stages of cervical cancer and has been suggested to be a prognostic marker of disease recurrences and metastases. Only a few studies have reported the presence of HPV DNA in bloodstream of patients with low grade or precancerous cervical lesions. This study aimed to define if HPV DNA could be detected in plasma samples of 120 women referred for a recent history of cervical dysplasia who presented with lesions ranging from High Squamous Intraepithelial Lesion (H-SIL) to regressed normal cytology. HPV DNA detection was carried out in both plasma and cervical samples using type-specific real-time quantitative PCR assays identifying oncogenic HPV 16, 18, 31, 33, 45, 51 and 52. Overall, 34.2% (41/120) of plasma samples were shown to be positive for HPV DNA detection; HPV 45 (46.3%), HPV-51 (29.6%), and HPV 16 (18.5%) were the most frequently identified genotypes. The rate of HPV detection in paired cervical and plasma samples increased with advancing disease stage, ranging from 15.4% in women with regressed lesions to 38.9% in women with HSIL; HPV 16 resulted the most common genotype identified in women found to be HPV DNA positive in both cervical and plasma samples. Moreover, HPV 16 showed the highest median viral load value in both cervical and plasma samples, with 48,313 copies/104 cells and 1,099 copies/ml, respectively. Results obtained in this study confirm that HPV DNA can be detected and quantified in plasma samples of women with asymptomatic cervical infection. Further knowledge on HPV dissemination through the blood stream of women with cervical lesions would be very important in better understanding the natural history of HPV infection as well as its potential role in other distant tumors. PMID:29182627

  9. Determination of 90Sr / 238U ratio by double isotope dilution inductively coupled plasma mass spectrometer with multiple collection in spent nuclear fuel samples with in situ 90Sr / 90Zr separation in a collision-reaction cell

    NASA Astrophysics Data System (ADS)

    Isnard, H.; Aubert, M.; Blanchet, P.; Brennetot, R.; Chartier, F.; Geertsen, V.; Manuguerra, F.

    2006-02-01

    Strontium-90 is one of the most important fission products generated in nuclear industry. In the research field concerning nuclear waste disposal in deep geological environment, it is necessary to quantify accurately and precisely its concentration (or the 90Sr / 238U atomic ratio) in irradiated fuels. To obtain accurate analysis of radioactive 90Sr, mass spectrometry associated with isotope dilution is the most appropriated method. But, in nuclear fuel samples the interference with 90Zr must be previously eliminated. An inductively coupled plasma mass spectrometer with multiple collection, equipped with an hexapole collision cell, has been used to eliminate the 90Sr / 90Zr interference by addition of oxygen in the collision cell as a reactant gas. Zr + ions are converted into ZrO +, whereas Sr + ions are not reactive. A mixed solution, prepared from a solution of enriched 84Sr and a solution of enriched 235U was then used to quantify the 90Sr / 238U ratio in spent fuel sample solutions using the double isotope dilution method. This paper shows the results, the reproducibility and the uncertainties that can be obtained with this method to quantify the 90Sr / 238U atomic ratio in an UOX (uranium oxide) and a MOX (mixed oxide) spent fuel samples using the collision cell of an inductively coupled plasma mass spectrometer with multiple collection to perform the 90Sr / 90Zr separation. A comparison with the results obtained by inductively coupled plasma mass spectrometer with multiple collection after a chemical separation of strontium from zirconium using a Sr spec resin (Eichrom) has been performed. Finally, to validate the analytical procedure developed, measurements of the same samples have been performed by thermal ionization mass spectrometry, used as an independent technique, after chemical separation of Sr.

  10. Drug use in pregnant women-a pilot study of the coherence between reported use of drugs and presence of drugs in plasma.

    PubMed

    Wolgast, Emelie; Josefsson, Ann; Josefsson, Martin; Lilliecreutz, Caroline; Reis, Margareta

    2018-04-01

    In Sweden, information on drug use during pregnancy is obtained through an interview and recorded in a standardized medical record at every visit to the antenatal care clinic throughout the pregnancy. Antenatal, delivery, and neonatal records constitute the basis for the Swedish Medical Birth Register (MBR). The purpose of this exploratory study was to investigate the reliability of reported drug use by simultaneous screening for drug substances in the blood stream of the pregnant woman and thereby validate self-reported data in the MBR. Plasma samples from 200 women were obtained at gestational weeks 10-12 and 25 and screened for drugs by using ultra-high performance liquid chromatography with time of flight mass spectrometry (UHPLC-TOF-MS). The results from the analysis were then compared to medical records. At the first sampling occasion, the drugs found by screening had been reported by 86% of the women and on the second sampling, 85.5%. Missed reported information was clearly associated with drugs for occasional use. The most common drugs in plasma taken in early and mid-pregnancy were meclizine and paracetamol. Two types of continuously used drugs, selective serotonin reuptake inhibitors and propranolol, were used. All women using them reported it and the drug screening revealed a 100% coherence. This study shows good coherence between reported drug intake and the drugs found in plasma samples, which in turn positively validates the MBR.

  11. IMPROVED DERIVATION OF INPUT FUNCTION IN DYNAMIC MOUSE [18F]FDG PET USING BLADDER RADIOACTIVITY KINETICS

    PubMed Central

    Wong, Koon-Pong; Zhang, Xiaoli; Huang, Sung-Cheng

    2013-01-01

    Purpose Accurate determination of the plasma input function (IF) is essential for absolute quantification of physiological parameters in positron emission tomography (PET). However, it requires an invasive and tedious procedure of arterial blood sampling that is challenging in mice because of the limited blood volume. In this study, a hybrid modeling approach is proposed to estimate the plasma IF of 2-deoxy-2-[18F]fluoro-D-glucose ([18F]FDG) in mice using accumulated radioactivity in urinary bladder together with a single late-time blood sample measurement. Methods Dynamic PET scans were performed on nine isoflurane-anesthetized male C57BL/6 mice after a bolus injection of [18F]FDG at the lateral caudal vein. During a 60- or 90-min scan, serial blood samples were taken from the femoral artery. Image data were reconstructed using filtered backprojection with CT-based attenuation correction. Total accumulated radioactivity in the urinary bladder was fitted to a renal compartmental model with the last blood sample and a 1-exponential function that described the [18F]FDG clearance in blood. Multiple late-time blood sample estimates were calculated by the blood [18F]FDG clearance equation. A sum of 4-exponentials was assumed for the plasma IF that served as a forcing function to all tissues. The estimated plasma IF was obtained by simultaneously fitting the [18F]FDG model to the time-activity curves (TACs) of liver and muscle and the forcing function to early (0–1 min) left-ventricle data (corrected for delay, dispersion, partial-volume effects and erythrocytes uptake) and the late-time blood estimates. Using only the blood sample acquired at the end of the study to estimate the IF and the use of liver TAC as an alternative IF were also investigated. Results The area under the plasma TACs calculated for all studies using the hybrid approach was not significantly different from that using all blood samples. [18F]FDG uptake constants in brain, myocardium, skeletal muscle and liver computed by the Patlak analysis using estimated and measured plasma TACs were in excellent agreement (slope ~ 1; R2 > 0.938). The IF estimated using only the last blood sample acquired at the end of the study and the use of liver TAC as plasma IF provided less reliable results. Conclusions The estimated plasma IFs obtained with the hybrid model agreed well with those derived from arterial blood sampling. Importantly, the proposed method obviates the need of arterial catheterization, making it possible to perform repeated dynamic [18F]FDG PET studies on the same animal. Liver TAC is unsuitable as an input function for absolute quantification of [18F]FDG PET data. PMID:23322346

  12. Spark plasma sintering synthesis of Ni1-xZnxFe2O4 ferrites: Mössbauer and catalytic study

    NASA Astrophysics Data System (ADS)

    Velinov, Nikolay; Manova, Elina; Tsoncheva, Tanya; Estournès, Claude; Paneva, Daniela; Tenchev, Krassimir; Petkova, Vilma; Koleva, Kremena; Kunev, Boris; Mitov, Ivan

    2012-08-01

    Nickel-zinc ferrite nanoparticles, Ni1-xZnxFe2O4 (x = 0, 0.2, 0.5, 0.8, 1.0) were prepared by combination of chemical precipitation and spark plasma sintering (SPS) techniques and conventional thermal treatment of the obtained precursors. The phase composition and structural properties of the obtained materials were investigated by X-ray diffraction and Mössbauer spectroscopy and their catalytic activity in methanol decomposition was tested. A strong effect of reaction medium leading to the transformation of ferrites to a complex mixture of different iron containing phases was detected. A tendency of formation of Fe-carbide was found for the samples synthesized by SPS, while predominantly iron-nickel alloys ware registered in TS obtained samples. The catalytic activity and selectivity in methanol decomposition to CO and methane depended on the current phase composition of the obtained ferrites, which was formed by the influence of the reaction medium.

  13. Plasma endotoxin activity in kangaroos with oral necrobacillosis (lumpy jaw disease) using an automated handheld testing system

    PubMed Central

    SOTOHIRA, Yukari; SUZUKI, Kazuyuki; SASAKI, Haruka; SANO, Tadashi; TSUCHIYA, Masakazu; SUZUKI, Yohko; SHIMAMORI, Toshio; TSUKANO, Kenji; SATO, Ayano; YOKOTA, Hiroshi; ASAKAWA, Mitsuhiko

    2016-01-01

    The aim of the present study was to evaluate the reliability and effectiveness of directly determining endotoxin activity in plasma samples from kangaroos with lumpy jaw disease (LJD, n=15) and healthy controls (n=12). Prior to the present study, the ability of the commercially available automated handheld portable test system (PTSTM) to detect endotoxin activity in kangaroo plasma was compared with that of the traditional LAL-kinetic turbidimetric (KT) assay. Plasma samples, which were obtained from endotoxin-challenged cattle, were diluted 1:20 in endotoxin-free water and heated to 80°C for 10 min. The performance of the PTSTM was not significantly different from that of the traditional LAL-based assay. The data obtained using PTSTM correlated with those using KT (r2=0.963, P<0.001). These findings indicated that the PTSTM is applicable as a simplified system to assess endotoxin activity in macropods. In the present study, we demonstrated the diagnostic value of plasma endotoxin activity in kangaroos with systemic inflammation caused by oral necrobacillosis and identified plasma endotoxin activity as a sensitive marker of systemic inflammation in kangaroos with LJD. Based on ROC curves, we proposed a diagnostic cut-off point for endotoxin activity of >0.22 EU/ml for the identification of LJD. Our results indicate that the assessment of plasma endotoxin activity is a promising diagnostic tool for determining the outcome of LJD in captive macropods. PMID:26902804

  14. Plasma endotoxin activity in kangaroos with oral necrobacillosis (lumpy jaw disease) using an automated handheld testing system.

    PubMed

    Sotohira, Yukari; Suzuki, Kazuyuki; Sasaki, Haruka; Sano, Tadashi; Tsuchiya, Masakazu; Suzuki, Yohko; Shimamori, Toshio; Tsukano, Kenji; Sato, Ayano; Yokota, Hiroshi; Asakawa, Mitsuhiko

    2016-07-01

    The aim of the present study was to evaluate the reliability and effectiveness of directly determining endotoxin activity in plasma samples from kangaroos with lumpy jaw disease (LJD, n=15) and healthy controls (n=12). Prior to the present study, the ability of the commercially available automated handheld portable test system (PTS(TM)) to detect endotoxin activity in kangaroo plasma was compared with that of the traditional LAL-kinetic turbidimetric (KT) assay. Plasma samples, which were obtained from endotoxin-challenged cattle, were diluted 1:20 in endotoxin-free water and heated to 80°C for 10 min. The performance of the PTS(TM) was not significantly different from that of the traditional LAL-based assay. The data obtained using PTS(TM) correlated with those using KT (r(2)=0.963, P<0.001). These findings indicated that the PTS(TM) is applicable as a simplified system to assess endotoxin activity in macropods. In the present study, we demonstrated the diagnostic value of plasma endotoxin activity in kangaroos with systemic inflammation caused by oral necrobacillosis and identified plasma endotoxin activity as a sensitive marker of systemic inflammation in kangaroos with LJD. Based on ROC curves, we proposed a diagnostic cut-off point for endotoxin activity of >0.22 EU/ml for the identification of LJD. Our results indicate that the assessment of plasma endotoxin activity is a promising diagnostic tool for determining the outcome of LJD in captive macropods.

  15. Study of the wear resistance of ion-plasma coatings based on titanium and aluminum and obtained by magnetron sputtering

    NASA Astrophysics Data System (ADS)

    Kachalin, G. V.; Mednikov, A. F.; Tkhabisimov, A. B.; Sidorov, S. V.

    2017-05-01

    The paper presents the results of metallographic researches and erosion tests of ion-plasma coatings (based on titanium, aluminum and their nitrides), which were formed on samples of 12Kh13 and EI961 blade steels. Erosion tests and studies of characteristics of obtained by magnetron sputtering coatings were carried out by using a set of research equipment UNU “Erosion-M” NRU “MPEI”. It was found that the formed Ti/Al-TiN/AlN coatings increase the duration of blade steels erosion wear incubation period by at least in 1.5 times and have a layered structure with thicknesses of nitride layers 1.3-1.6 μm and intermediate metallic layers 0.3-0.5 μm, with a total thickness of coatings of 10-14 μm for 12Kh13steel samples and 19-21 μm for EI961 steel samples.

  16. Comparison of EML 105 and advantage analysers measuring capillary versus venous whole blood glucose in neonates.

    PubMed

    McNamara, P J; Sharief, N

    2001-09-01

    Near-patient blood glucose monitoring is an essential component of neonatal intensive care but the analysers currently used are unreliable and inaccurate. The aim of this study was to compare a new glucose electrode-based analyser (EML 105) and a non-wipe reflectance photometry method (Advantage) as opposed to a recognized laboratory reference method (Hexokinase). We also investigated the effect of sample route and haematocrit on the accuracy of the glucose readings obtained by each method of analysis. Whole blood glucose concentrations ranging from 0 to 3.5 mmol/l were carefully prepared in a laboratory setting and blood samples from each respective solution were then measured by EML 105 and Advantage analysers. The results obtained were then compared with the corresponding plasma glucose reading obtained by the Hexokinase method, using linear regression analysis. An in vivo study was subsequently performed on 103 neonates, over a 1-y period, using capillary and venous whole blood samples. Whole blood glucose concentration was estimated from each sample using both analysers and compared with the corresponding plasma glucose concentration estimated by the Hexokinase method. Venous blood was centrifuged and haematocrit was estimated using standardized curves. The effect of haematocrit on the agreement between whole blood and plasma glucose was investigated, estimating the degree of correlation on a scatterplot of the results and linear regression analysis. Both the EML 105 and Hexokinase methods were highly accurate, in vitro, with small proportional biases of 2% and 5%, respectively. However, in vivo, both study analysers overestimated neonatal plasma glucose, ranging from at best 0.45 mmol/l (EML 105 venous) to 0.69 mmol/l (EML capillary). There was no significant difference in the agreement of capillary (GD = 0.12, 95% CI, [-0.32,0.08], p = 0.2) or venous samples (GD = 0.05, 95% CI. [0.09, 0.19], p = 0.49) with plasma glucose when analysed by either study method (GD = glucose difference between study analyser and reference method) However, the venous samples analysed by EML 105 estimated plasma glucose significantly better than capillary samples using the same method of analysis (GD = 0.24, 95% CI. [0.09,0.38], p < 0.01). The relationship between haematocrit and the resultant glucose differences was non-linear with correlation coefficients of r = -0.057 (EML 105 capillary), r = 0.145 (EML 105 venous), r = -0.127 (Advantage capillary) and r = -0.275 (Advantage venous). There was no significant difference in the effect of haematocrit on the performance of EML 105 versus Advantage, regardless of the sample route. Both EML 105 and Advantage overestimated plasma glucose, with no significant difference in the performance of either analyser, regardless of the route of analysis. Agreement with plasma glucose was better for venous samples but this was only statistically significant when EML 105 capillary and venous results were compared. Haematocrit is not a significant confounding factor towards the performance of either EML 105 or Advantage in neonates, regardless of the route of sampling. The margin of overestimation of blood glucose prohibits the recommendation of both EML 105 and Advantage for routine neonatal glucose screening. The consequences include failure accurately to diagnose hypoglycaemia and delays in the instigation of therapeutic measures, both of which may potentially result in an adverse, long-term, neurodevelopmental outcome.

  17. Evaluation of Penicillium digitatum sterilization using non-equilibrium atmospheric pressure plasma by terahertz time-domain spectroscopy

    NASA Astrophysics Data System (ADS)

    Hiraoka, Takehiro; Ebizuka, Noboru; Takeda, Keigo; Ohta, Takayuki; Kondo, Hiroki; Ishikawa, Kenji; Kawase, Kodo; Ito, Masafumi; Sekine, Makoto; Hori, Masaru

    2011-10-01

    Recently, the plasma sterilization has attracted much attention as a new sterilization technique that takes the place of spraying agricultural chemicals. The conventional methods for sterilization evaluation, was demanded to culture the samples for several days after plasma treatment. Then, we focused on Terahertz time-domain spectroscopy (THz-TDS). At the THz region, vibrational modes of biological molecules and fingerprint spectra of biologically-relevant molecules were also observed. In this study, our purpose was measurement of the fingerprint spectrum of the Penicillium digitatum (PD) spore and establishment of sterilization method by THz-TDS. The sample was 40mg/ml PD spore suspensions which dropped on cover glass. The atmospheric pressure plasma generated under the conditions which Ar gas flow was 3slm, and alternating voltage of 6kV was applied. The samples were exposed the plasma from 10mm distance for 10 minutes. We could obtain the fingerprint spectrum of the PD spore from 0.5 to 0.9THz. This result indicated the possibility of in-situ evaluation for PD sterilization using THz-TDS.

  18. Effect of storage duration on cytokine stability in human serum and plasma.

    PubMed

    Vincent, Fabien B; Nim, Hieu T; Lee, Jacinta P W; Morand, Eric F; Harris, James

    2018-06-14

    Quantification of analytes such as cytokines in serum samples is intrinsic to translational research in immune diseases. Optimising pre-analytical conditions is critical for ensuring study quality, including evaluation of cytokine stability. We aimed to evaluate the effect on cytokine stability of storage duration prior to freezing of serum, and compare to plasma samples obtained from patients with systemic lupus erythematosus (SLE). Protein stability was analysed by simultaneously quantifying 18 analytes using a custom multi-analyte profile in SLE patient serum and plasma samples that had been prospectively stored at 4 °C for pre-determined periods between 0 and 30 days, prior to freezing. Six analytes were excluded from analysis, because most tested samples were above or below the limit of detection. Amongst the 12 analysed proteins, 11 did not show significant signal degradation. Significant signal degradation was observed from the fourth day of storage for a single analyte, CCL19. Proteins levels were more stable in unseparated serum compared to plasma for most analytes, with the exception of IL-37 which appears slightly more stable in plasma. Based on this, a maximum 3 days of storage at 4 °C for unseparated serum samples is recommended for biobanked samples intended for cytokine analysis in studies of human immune disease. Copyright © 2018 Elsevier Ltd. All rights reserved.

  19. Clinical Validation of Therapeutic Drug Monitoring of Imipenem in Spent Effluent in Critically Ill Patients Receiving Continuous Renal Replacement Therapy: A Pilot Study

    PubMed Central

    Wen, Aiping; Li, Zhe; Yu, Junxian; Li, Ren; Cheng, Sheng; Duan, Meili; Bai, Jing

    2016-01-01

    Objectives The primary objective of this pilot study was to investigate whether the therapeutic drug monitoring of imipenem could be performed with spent effluent instead of blood sampling collected from critically ill patients under continuous renal replacement therapy. Methods A prospective open-label study was conducted in a real clinical setting. Both blood and effluent samples were collected pairwise before imipenem administration and 0.5, 1, 1.5, 2, 3, 4, 6, and 8 h after imipenem administration. Plasma and effluent imipenem concentrations were determined by reversed-phase high-performance liquid chromatography with ultraviolet detection. Pharmacokinetic and pharmacodynamic parameters of blood and effluent samples were calculated. Results Eighty-three paired plasma and effluent samples were obtained from 10 patients. The Pearson correlation coefficient of the imipenem concentrations in plasma and effluent was 0.950 (P<0.0001). The average plasma-to-effluent imipenem concentration ratio was 1.044 (95% confidence interval, 0.975 to 1.114) with Bland-Altman analysis. No statistically significant difference was found in the pharmacokinetic and pharmacodynamic parameters tested in paired plasma and effluent samples with Wilcoxon test. Conclusion Spent effluent of continuous renal replacement therapy could be used for therapeutic drug monitoring of imipenem instead of blood sampling in critically ill patients. PMID:27093294

  20. A simple competitive RT-PCR assay for quantitation of HIV-1 subtype B and non-B RNA in plasma.

    PubMed

    Hamatake, Makiko; Nishizawa, Masako; Yamamoto, Naoki; Kato, Shingo; Sugiura, Wataru

    2007-06-01

    An easy, inexpensive competitive RT-PCR assay for HIV-1 RNA quantitation was constructed. A 138-bp sequence in the HIV-1 gag p24 region was selected as the target and co-amplified with competitor RNA containing an internal 44-bp deletion. Quantitation of serial dilutions of control RNA samples prepared from the LAI isolate demonstrated a good linearity (R(2)=0.991) within the range between 10 and 250 copies/sample. The detection limit of the assay was determined to be 3.8 copies/sample by Probit analysis and corresponded to 110 copies/ml in plasma. The intra-assay CV value was 9.1%, and the inter-assay value was 25.9%. Both were comparable to those obtained with commercially available HIV-1 RNA quantitation kits. The correlation efficient for the results obtained in 47 plasma samples from HIV-1-infected individuals (subtype A in 1, subtype B in 25, subtype C in 4, subtype F in 1, and CRF01 AE in 16) with the competitive RT-PCR and Cobas Amplicor HIV-1 Monitor test v1.5 was 0.956 for subtype B and 0.947 for subtype non-B. The assay devised is a good alternative for monitoring antiretroviral therapy in resource-poor countries.

  1. An environmentally-friendly, highly efficient, gas pressure-assisted sample introduction system for ICP-MS and its application to detection of cadmium and lead in human plasma.

    PubMed

    Cao, Yupin; Deng, Biyang; Yan, Lizhen; Huang, Hongli

    2017-05-15

    An environmentally friendly and highly efficient gas pressure-assisted sample introduction system (GPASIS) was developed for inductively-coupled plasma mass spectrometry. A GPASIS consisting of a gas-pressure control device, a customized nebulizer, and a custom-made spray chamber was fabricated. The advantages of this GPASIS derive from its high nebulization efficiencies, small sample volume requirements, low memory effects, good precision, and zero waste emission. A GPASIS can continuously, and stably, nebulize 10% NaCl solution for more than an hour without clogging. Sensitivity, detection limits, precision, long-term stability, double charge and oxide ion levels, nebulization efficiencies, and matrix effects of the sample introduction system were evaluated. Experimental results indicated that the performance of this GPASIS, was equivalent to, or better than, those obtained by conventional sample introduction systems. This GPASIS was successfully used to determine Cd and Pb by ICP-MS in human plasma. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. Production of organic compounds in plasmas - A comparison among electric sparks, laser-induced plasmas, and UV light

    NASA Technical Reports Server (NTRS)

    Scattergood, Thomas W.; Mckay, Christopher P.; Borucki, William J.; Giver, Lawrence P.; Van Ghyseghem, Hilde

    1989-01-01

    In order to ascertain the features of organic compound-production in planetary atmospheres under the effects of plasmas and shocks, various mixtures of N2, CH4, and H2 modeling the atmosphere of Titan were subjected to discrete sparks, laser-induced plasmas, and UV radiation. The experimental results obtained suggest that UV photolysis from the plasma is an important organic compound synthesis process, as confirmed by the photolysis of gas samples that were exposed to the light but not to the shock waves emitted by the sparks. The thermodynamic equilibrium theory is therefore incomplete in the absence of photolysis.

  3. Errors in calculated oncotic pressure of dog plasma.

    PubMed

    Gabel, J C; Scott, R L; Adair, T H; Drake, R E; Traber, D L

    1980-12-01

    Several equations to calculate plasma oncotic pressure (pi) from the total protein concentration (C) have been previously described. These equations were derived empirically from samples with a wide range of C obtained by diluting or concentrating normal plasma samples. To test these equations over a range of naturally occurring C, we measured C and pi of plasma samples from 40 dogs. C ranged from 5.3 to 8.7 g/dl and averaged 6.5 +/- 0.1 (mean +/- SE) and pi averaged 17.9 +/- 0.3 mmHg. The regression equation was pi = 78.14 + 1.67 C (r = 0.74). pi increased with C much less than predicted with the commonly used equations. The albumin-to-globulin concentration ratios (A/G), determined in 27 of the dogs, decreased with increasing C (A/G = 1.56-0.128 C, r = 0.62). The lower A/G at the higher C's could cause the lower than predicted increase in pi with C, because the equations were developed from data in which A/G was constant.

  4. Study of the effects of E × B fields as mechanism to carbon-nitrogen plasma immersion ion implantation on stainless steel samples

    NASA Astrophysics Data System (ADS)

    Pillaca, E. J. D. M.; Ueda, M.; Oliveira, R. M.; Pichon, L.

    2014-08-01

    Effects of E × B fields as mechanism to carbon-nitrogen plasma immersion ion implantation (PIII) have been investigated. This magnetic configuration when used in PIII allows obtaining high nitrogen plasma density close to the ion implantation region. Consequently, high ions dose on the target is possible to be achieved compared with standard PIII. In this scenario, nitrogen and carbon ions were implanted simultaneously on stainless steel, as measured by GDOES and detected by X-ray diffraction. Carbon-tape disposed on the sample-holder was sputtered by intense bombardment of nitrogen ions, being the source of carbon atoms in this experiment. The implantation of both N and C caused changes on sample morphology and improvement of the tribological properties of the stainless steel.

  5. Notes on the plasma resonance peak employed to determine doping in SiC

    DOE PAGES

    Engelbrecht, J. A. A.; van Rooyen, I. J.; Henry, A.; ...

    2015-07-23

    In this study, the doping level of a semiconductor material can be determined using the plasma resonance frequency to obtain the carrier concentration associated with doping. This paper provides an overview of the procedure for the three most common polytypes of SiC. Results for 3C-SiC are presented and discussed. In phosphorus doped samples analysed, it is submitted that the 2nd plasma resonance cannot be detected due to high values of the free carrier damping constant γ.

  6. Charge-exchange plasma generated by an ion thruster

    NASA Technical Reports Server (NTRS)

    Kaufman, H. R.

    1977-01-01

    The charge exchange plasma generated by an ion thruster was investigated experimentally using both 5 cm and 15 cm thrusters. Results are shown for wide ranges of radial distance from the thruster and angle from the beam direction. Considerations of test environment, as well as distance from the thruster, indicate that a valid simulation of a thruster on a spacecraft was obtained. A calculation procedure and a sample calculation of charge exchange plasma density and saturation electron current density are included.

  7. Determination of oxycodone and its major metabolites noroxycodone and oxymorphone by ultra-high-performance liquid chromatography tandem mass spectrometry in plasma and urine: application to real cases.

    PubMed

    Pantano, Flaminia; Brauneis, Stefano; Forneris, Alexandre; Pacifici, Roberta; Marinelli, Enrico; Kyriakou, Chrystalla; Pichini, Simona; Busardò, Francesco Paolo

    2017-08-28

    Oxycodone is a narcotic drug widely used to alleviate moderate and severe acute and chronic pain. Variability in analgesic efficacy could be explained by inter-subject variations in plasma concentrations of parent drug and its active metabolite, oxymorphone. To evaluate patient compliance and to set up therapeutic drug monitoring (TDM), an ultra-high-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) assay was developed and validated for the parent drug and its major metabolites noroxycodone and oxymorphone. Extraction of analytes from plasma and urine samples was obtained by simple liquid-liquid extraction. The chromatographic separation was achieved with a reversed phase column using a linear gradient elution with two solvents: acetic acid 1% in water and methanol. The separated analytes were detected with a triple quadrupole mass spectrometer operated in multiple reaction monitoring (MRM) mode via positive electrospray ionization (ESI). Separation of analytes was obtained in less than 5 min. Linear calibration curves for all the analytes under investigation in urine and plasma samples showed determination coefficients (r2) equal or higher than 0.990. Mean absolute analytical recoveries were always above 86%. Intra- and inter-assay precision (measured as coefficient of variation, CV%) and accuracy (measured as % error) values were always better than 13%. Limit of detection at 0.06 and 0.15 ng/mL and limit of quantification at 0.2 and 0.5 ng/mL for plasma and urine samples, respectively, were adequate for the purpose of the present study. Rapid extraction, identification and quantification of oxycodone and its metabolites both in urine and plasma by UHPLC-MS/MS assay was tested for its feasibility in clinical samples and provided excellent results for rapid and effective drug testing in patients under oxycodone treatment.

  8. Assay for the simultaneous determination of guanidinoacetic acid, creatinine and creatine in plasma and urine by capillary electrophoresis UV-detection.

    PubMed

    Zinellu, Angelo; Sotgia, Salvatore; Zinellu, Elisabetta; Chessa, Roberto; Deiana, Luca; Carru, Ciriaco

    2006-03-01

    Guanidinoacetic acid (GAA) measurement has recently become of great interest for the diagnosis of creatine (Cn) metabolism disorders, and research calls for rapid and inexpensive methods for its detection in plasma and urine in order to assess a large number of patients. We propose a new assay for the measurement of GAA by a simple CZE UV-detection without previous sample derivatization. Plasma samples were filtered by Microcon-10 microconcentrators and directly injected into the capillary, while for urine specimens a simple water dilution before injection was needed. A baseline separation was obtained in less than 8 min using a 60.2 cm x 75 microm uncoated silica capillary, 75 mmol/L Tris-phosphate buffer pH 2.25 at 15 degrees C. The performance of the developed method was assessed by measuring plasma creatinine and Cn in 32 normal subjects and comparing the data obtained by the new method with those found with the previous CE assay. Our new method seems to be an inexpensive, fast and specific tool to assess a large number of patients both in clinical and in research laboratories.

  9. Potentiometric detection in UPLC as an easy alternative to determine cocaine in biological samples.

    PubMed

    Daems, Devin; van Nuijs, Alexander L N; Covaci, Adrian; Hamidi-Asl, Ezat; Van Camp, Guy; Nagels, Luc J

    2015-07-01

    The analytical methods which are often used for the determination of cocaine in complex biological matrices are a prescreening immunoassay and confirmation by chromatography combined with mass spectrometry. We suggest an ultra-high-pressure liquid chromatography combined with a potentiometric detector, as a fast and practical method to detect and quantify cocaine in biological samples. An adsorption/desorption model was used to investigate the usefulness of the potentiometric detector to determine cocaine in complex matrices. Detection limits of 6.3 ng mL(-1) were obtained in plasma and urine, which is below the maximum residue limit (MRL) of 25 ng mL(-1). A set of seven plasma samples and 10 urine samples were classified identically by both methods as exceeding the MRL or being inferior to it. The results obtained with the UPLC/potentiometric detection method were compared with the results obtained with the UPLC/MS method for samples spiked with varying cocaine concentrations. The intraclass correlation coefficient was 0.997 for serum (n =7) and 0.977 for urine (n =8). As liquid chromatography is an established technique, and as potentiometry is very simple and cost-effective in terms of equipment, we believe that this method is potentially easy, inexpensive, fast and reliable. Copyright © 2014 John Wiley & Sons, Ltd.

  10. Determination of arsenic in traditional Chinese medicine by microwave digestion with flow injection-inductively coupled plasma mass spectrometry (FI-ICP-MS).

    PubMed

    Ong, E S; Yong, Y L; Woo, S O

    1999-01-01

    A simple, rapid, and sensitive method with high sample throughput was developed for determining arsenic in traditional Chinese medicine (TCM) in the form of uncoated tablets, sugar-coated tablets, black pills, capsules, powders, and syrups. The method involves microwave digestion with flow injection-inductively coupled plasma mass spectrometry (FI-ICP-MS). Method precision was 2.7-10.1% (relative standard deviation, n = 6) for different concentrations of arsenic in different TCM samples analyzed by different analysts on different days. Method accuracy was checked with a certified reference material (sea lettuce, Ulva lactuca, BCR CRM 279) for external calibration and by spiking arsenic standard into different TCMs. Recoveries of 89-92% were obtained for the certified reference material and higher than 95% for spiked TCMs. Matrix interference was insignificant for samples analyzed by the method of standard addition. Hence, no correction equation was used in the analysis of arsenic in the samples studied. Sample preparation using microwave digestion gave results that were very similar to those obtained by conventional wet acid digestion using nitric acid.

  11. Blood Substrate Collection and Handling Procedures under Pseudo-Field Conditions: Evaluation of Suitability for Inflammatory Biomarker Measurement.

    PubMed

    Sugden, Karen; Danese, Andrea; Shalev, Idan; Williams, Benjamin S; Caspi, Avshalom

    2015-01-01

    Routine incorporation of blood-based biomarker measurements in population studies has been hampered by challenges in obtaining samples suitable for biomarker assessment outside of laboratory settings. Here, we assessed the suitability of venous blood left unprocessed for 4, 24, or 48 hours post-collection at either room temperature or 4°C for quantification of two biomarkers, Interleukin-6 (IL-6) and C-reactive protein (CRP). Blood samples were collected in both K2EDTA tubes and a dedicated plasma-preservation tube, P100. Dried blood spot (DBS) samples from the same subjects were also collected in order to compare delayed-processing plasma performance against a popular alternative collection method. We found that K2EDTA mean plasma concentrations of both IL-6 and CRP were not significantly different from concentrations in plasma processed immediately; this was observed for tubes stored up to 48 hours pre-processing at either temperature. Concentrations of IL-6 measured in P100 tubes showed significant time-dependent increases when stored at room temperature; otherwise, levels of IL-6 and CRP were similar to those found in samples processed immediately. Levels of CRP in DBS were correlated with plasma CRP levels, even when pre-processed blood was stored for up to 48 hours. These data indicate that plasma is suitable for IL-6 and CRP estimation under data collection conditions that involve processing delays.

  12. Method and system of Jones-matrix mapping of blood plasma films with "fuzzy" analysis in differentiation of breast pathology changes

    NASA Astrophysics Data System (ADS)

    Zabolotna, Natalia I.; Radchenko, Kostiantyn O.; Karas, Oleksandr V.

    2018-01-01

    A fibroadenoma diagnosing of breast using statistical analysis (determination and analysis of statistical moments of the 1st-4th order) of the obtained polarization images of Jones matrix imaginary elements of the optically thin (attenuation coefficient τ <= 0,1 ) blood plasma films with further intellectual differentiation based on the method of "fuzzy" logic and discriminant analysis were proposed. The accuracy of the intellectual differentiation of blood plasma samples to the "norm" and "fibroadenoma" of breast was 82.7% by the method of linear discriminant analysis, and by the "fuzzy" logic method is 95.3%. The obtained results allow to confirm the potentially high level of reliability of the method of differentiation by "fuzzy" analysis.

  13. Simple, miniaturized blood plasma extraction method.

    PubMed

    Kim, Jin-Hee; Woenker, Timothy; Adamec, Jiri; Regnier, Fred E

    2013-12-03

    A rapid plasma extraction technology that collects a 2.5 μL aliquot of plasma within three minutes from a finger-stick derived drop of blood was evaluated. The utility of the plasma extraction cards used was that a paper collection disc bearing plasma was produced that could be air-dried in fifteen minutes and placed in a mailing envelop for transport to an analytical laboratory. This circumvents the need for venipuncture and blood collection in specialized vials by a phlebotomist along with centrifugation and refrigerated storage. Plasma extraction was achieved by applying a blood drop to a membrane stack through which plasma was drawn by capillary action. During the course of plasma migration to a collection disc at the bottom of the membrane stack blood cells were removed by a combination of adsorption and filtration. After the collection disc filled with an aliquot of plasma the upper membranes were stripped from the collection card and the collection disc was air-dried. Intercard differences in the volume of plasma collected varied approximately 1% while volume variations of less than 2% were seen with hematocrit levels ranging from 20% to 71%. Dried samples bearing metabolites and proteins were then extracted from the disc and analyzed. 25-Hydroxy vitamin D was quantified by LC-MS/MS analysis following derivatization with a secosteroid signal enhancing tag that imparted a permanent positive charge to the vitamin and reduced the limit of quantification (LOQ) to 1 pg of collected vitamin on the disc; comparable to values observed with liquid-liquid extraction (LLE) of a venipuncture sample. A similar study using conventional proteomics methods and spectral counting for quantification was conducted with yeast enolase added to serum as an internal standard. The LOQ with extracted serum samples for enolase was 1 μM, linear from 1 to 40 μM, the highest concentration examined. In all respects protein quantification with extracted serum samples was comparable to that observed with serum samples obtained by venipuncture.

  14. A validated UPLC-MS/MS method for the analysis of linezolid and a novel oxazolidinone derivative (PH027) in plasma and its application to tissue distribution study in rabbits.

    PubMed

    Hedaya, Mohsen A; Thomas, Vidhya; Abdel-Hamid, Mohamed E; Kehinde, Elijah O; Phillips, Oludotun A

    2017-01-01

    Linezolid is the first approved oxazolidinone antibacterial agent, whereas PH027 is a novel compound of the same class that exhibits good in vitro antibacterial activity. The objective of this study was to develop an UPLC-MS/MS assay for the analysis of linezolid and PH027 in plasma and to apply the method for comparative pharmacokinetic and tissue distribution studies of both compounds. Plasma samples and calibrators were extracted with diethyl ether after addition of the internal standard solution. After evaporation of the ether layer, the residue was reconstituted in mobile phase and injected into UPLC-MS/MS. The mobile phase consisted of 2mM ammonium acetate buffer solution and acetonitrile (70:30) at a flow rate of 0.2ml/min. Separation was achieved using UPLC BEH C 18 column, and quantitative determination of the analytes was performed using multiple-reaction monitoring (MRM) scanning mode. The method was validated by analyzing quality control tissue homogenate samples, and was applied to analyze tissue homogenate samples obtained following IV injections of linezolid and PH027 in rabbits. The developed UPLC-MS/MS method was linear in the concentration range of 50-5000ng/ml. Validation of the method proved that the method's precision, selectivity and stability were all within the acceptable limits. Linezolid and PH027 concentrations were accurately determined in the quality control tissue homogenate samples, and analysis of samples obtained following IV administration of the two compounds showed that the tissue to plasma concentration ratio of PH027 was higher than that of linezolid probably due to its higher lipophilicity. The developed UPLC-MS/MS method for the analysis of linezolid and PH027 in rabbit's plasma can accurately determine the concentrations of these compounds in different tissues. Copyright © 2016 Elsevier B.V. All rights reserved.

  15. Exposure of infants to budesonide through breast milk of asthmatic mothers.

    PubMed

    Fält, Anette; Bengtsson, Thomas; Kennedy, Britt-Marie; Gyllenberg, Ann; Lindberg, Bengt; Thorsson, Lars; Stråndgarden, Kerstin

    2007-10-01

    Maintenance treatment with inhaled corticosteroids is often required for asthmatic nursing women. Data on the transfer of inhaled corticosteroids from plasma to breast milk and the subsequent exposure of the breast-feeding infant has been unavailable. We sought to assess budesonide concentrations in milk and plasma of asthmatic nursing women receiving maintenance treatment with the Pulmicort Turbuhaler and estimate the exposure of their breast-fed infants. Milk and plasma samples were collected up to 8 hours after dosing from 8 mothers receiving budesonide maintenance treatment (200 or 400 microg twice daily). Pharmacokinetic parameters were calculated from budesonide milk and plasma concentrations. Infant exposure was estimated based on average milk budesonide concentrations. A single blood sample was obtained from 5 infants close to expected infant maximum concentration. Budesonide concentrations in milk reflected those in maternal plasma, supporting passive diffusion of budesonide between plasma and milk, and was always lower than that in plasma. The mean milk/plasma ratio was 0.46. The estimated daily infant dose was 0.3% of the daily maternal dose for both dose levels, and the average plasma concentration in infants was estimated to be 1/600th of the concentrations observed in maternal plasma, assuming complete infant oral bioavailability. Budesonide concentrations in infant plasma samples were all less than the limit of quantification. Maintenance treatment with inhaled budesonide (200 or 400 microg twice daily) in asthmatic nursing women results in negligible systemic exposure to budesonide in breast-fed infants. These data support continued use of inhaled budesonide during breast-feeding.

  16. Selected problems with boron determination in water treatment processes. Part I: comparison of the reference methods for ICP-MS and ICP-OES determinations.

    PubMed

    Kmiecik, Ewa; Tomaszewska, Barbara; Wątor, Katarzyna; Bodzek, Michał

    2016-06-01

    The aim of the study was to compare the two reference methods for the determination of boron in water samples and further assess the impact of the method of preparation of samples for analysis on the results obtained. Samples were collected during different desalination processes, ultrafiltration and the double reverse osmosis system, connected in series. From each point, samples were prepared in four different ways: the first was filtered (through a membrane filter of 0.45 μm) and acidified (using 1 mL ultrapure nitric acid for each 100 mL of samples) (FA), the second was unfiltered and not acidified (UFNA), the third was filtered but not acidified (FNA), and finally, the fourth was unfiltered but acidified (UFA). All samples were analysed using two analytical methods: inductively coupled plasma mass spectrometry (ICP-MS) and inductively coupled plasma optical emission spectrometry (ICP-OES). The results obtained were compared and correlated, and the differences between them were studied. The results show that there are statistically significant differences between the concentrations obtained using the ICP-MS and ICP-OES techniques regardless of the methods of sampling preparation (sample filtration and preservation). Finally, both the ICP-MS and ICP-OES methods can be used for determination of the boron concentration in water. The differences in the boron concentrations obtained using these two methods can be caused by several high-level concentrations in selected whole-water digestates and some matrix effects. Higher concentrations of iron (from 1 to 20 mg/L) than chromium (0.02-1 mg/L) in the samples analysed can influence boron determination. When iron concentrations are high, we can observe the emission spectrum as a double joined and overlapping peak.

  17. Plasma circulating tumor DNA as an alternative to metastatic biopsies for mutational analysis in breast cancer.

    PubMed

    Rothé, F; Laes, J-F; Lambrechts, D; Smeets, D; Vincent, D; Maetens, M; Fumagalli, D; Michiels, S; Drisis, S; Moerman, C; Detiffe, J-P; Larsimont, D; Awada, A; Piccart, M; Sotiriou, C; Ignatiadis, M

    2014-10-01

    Molecular screening programs use next-generation sequencing (NGS) of cancer gene panels to analyze metastatic biopsies. We interrogated whether plasma could be used as an alternative to metastatic biopsies. The Ion AmpliSeq™ Cancer Hotspot Panel v2 (Ion Torrent), covering 2800 COSMIC mutations from 50 cancer genes was used to analyze 69 tumor (primary/metastases) and 31 plasma samples from 17 metastatic breast cancer patients. The targeted coverage for tumor DNA was ×1000 and for plasma cell-free DNA ×25 000. Whole blood normal DNA was used to exclude germline variants. The Illumina technology was used to confirm observed mutations. Evaluable NGS results were obtained for 60 tumor and 31 plasma samples from 17 patients. When tumor samples were analyzed, 12 of 17 (71%, 95% confidence interval (CI) 44% to 90%) patients had ≥1 mutation (median 1 mutation per patient, range 0-2 mutations) in either p53, PIK3CA, PTEN, AKT1 or IDH2 gene. When plasma samples were analyzed, 12 of 17 (71%, 95% CI: 44-90%) patients had ≥1 mutation (median 1 mutation per patient, range 0-2 mutations) in either p53, PIK3CA, PTEN, AKT1, IDH2 and SMAD4. All mutations were confirmed. When we focused on tumor and plasma samples collected at the same time-point, we observed that, in four patients, no mutation was identified in either tumor or plasma; in nine patients, the same mutations was identified in tumor and plasma; in two patients, a mutation was identified in tumor but not in plasma; in two patients, a mutation was identified in plasma but not in tumor. Thus, in 13 of 17 (76%, 95% CI 50% to 93%) patients, tumor and plasma provided concordant results whereas in 4 of 17 (24%, 95% CI 7% to 50%) patients, the results were discordant, providing complementary information. Plasma can be prospectively tested as an alternative to metastatic biopsies in molecular screening programs. © The Author 2014. Published by Oxford University Press on behalf of the European Society for Medical Oncology. All rights reserved. For permissions, please email: journals.permissions@oup.com.

  18. Tumor and Plasma Met Levels in Non-Metastatic Prostate Cancer.

    PubMed

    Kaye, Deborah R; Pinto, Peter A; Cecchi, Fabiola; Reilly, Joseph; Semerjian, Alice; Rabe, Daniel C; Gupta, Gopal; Choyke, Peter L; Bottaro, Donald P

    2016-01-01

    To measure Met protein content in prostate biopsies guided by fused magnetic resonance and ultrasound imaging, and to measure soluble Met (sMet) protein concentration in plasma samples from patients presenting evidence of prostate cancer. 345 patients had plasma samples drawn prior to image-guided biopsy of the prostate. Of these, 32% had benign biopsies. Of the 236 that were positive for prostate adenocarcinoma (PCa), 132 treated by total prostatectomy had Gleason scores of 6 (17%), 7, (55%), 8 (16%), or 9-10 (12%). 23% had evidence of local invasion. Plasma samples were also obtained from 80 healthy volunteers. Tissue Met and plasma sMet were measured by two-site immunoassay; values were compared among clinically defined groups using non-parametric statistical tests to determine significant differences or correlations. PCa tumor Met correlated significantly with plasma sMet, but median values were similar among benign and malignant groups. Median plasma sMet values were also similar among those groups, although both medians were significantly above normal. Median Met content in primary PCa tumors and sMet concentrations were independent of Gleason score, final pathologic stage and age. Plasma sMet is not predictive of PCa or its severity in patients with organ-confined or locally invasive disease. Quantitative analysis of Met protein content and activation state in PCa tumor biopsy samples was highly feasible and may have value in follow-up to genomic and/or transcriptomic-based screens that show evidence of oncogenically relevant MET gene features that occur at relatively low frequency in non-metastatic PCa.

  19. Subtype-independent near full-length HIV-1 genome sequencing and assembly to be used in large molecular epidemiological studies and clinical management.

    PubMed

    Grossmann, Sebastian; Nowak, Piotr; Neogi, Ujjwal

    2015-01-01

    HIV-1 near full-length genome (HIV-NFLG) sequencing from plasma is an attractive multidimensional tool to apply in large-scale population-based molecular epidemiological studies. It also enables genotypic resistance testing (GRT) for all drug target sites allowing effective intervention strategies for control and prevention in high-risk population groups. Thus, the main objective of this study was to develop a simplified subtype-independent, cost- and labour-efficient HIV-NFLG protocol that can be used in clinical management as well as in molecular epidemiological studies. Plasma samples (n=30) were obtained from HIV-1B (n=10), HIV-1C (n=10), CRF01_AE (n=5) and CRF01_AG (n=5) infected individuals with minimum viral load >1120 copies/ml. The amplification was performed with two large amplicons of 5.5 kb and 3.7 kb, sequenced with 17 primers to obtain HIV-NFLG. GRT was validated against ViroSeq™ HIV-1 Genotyping System. After excluding four plasma samples with low-quality RNA, a total of 26 samples were attempted. Among them, NFLG was obtained from 24 (92%) samples with the lowest viral load being 3000 copies/ml. High (>99%) concordance was observed between HIV-NFLG and ViroSeq™ when determining the drug resistance mutations (DRMs). The N384I connection mutation was additionally detected by NFLG in two samples. Our high efficiency subtype-independent HIV-NFLG is a simple and promising approach to be used in large-scale molecular epidemiological studies. It will facilitate the understanding of the HIV-1 pandemic population dynamics and outline effective intervention strategies. Furthermore, it can potentially be applicable in clinical management of drug resistance by evaluating DRMs against all available antiretrovirals in a single assay.

  20. Plasma lactate concentrations in free-ranging moose (Alces alces) immobilized with etorphine.

    PubMed

    Haga, Henning A; Wenger, Sandra; Hvarnes, Silje; Os, Oystein; Rolandsen, Christer M; Solberg, Erling J

    2009-11-01

    To investigate plasma lactate concentrations of etorphine-immobilized moose in relation to environmental, temporal and physiological parameters. Prospective clinical study. Fourteen female and five male moose (Alces alces), estimated age range 1-7 years. The moose were darted from a helicopter with 7.5 mg etorphine per animal using projectile syringes and a dart gun. Once immobilized, the moose were approached, a venous blood sample was obtained and vital signs including pulse oximetry were recorded. Diprenorphine was administered to reverse the effects of etorphine. Timing of events, ambient temperature and snow depth were recorded. Blood samples were cooled and centrifuged before plasma was harvested and frozen. The plasma was thawed later and lactate analysed. Data were analysed using descriptive statistics and regression analysis. All animals recovered uneventfully and were alive 12 weeks after immobilization. Mean +/- SD plasma lactate was found to be 9.2 +/- 2.1 mmol L(-1). Plasma lactate concentrations were related positively to snow depth and negatively to time from induction of immobilization to blood sampling. The model that best described the variability in plasma lactate concentrations used induction time (time from firing the dart to the moose being immobilized). The second best model included induction time and snow depth. Plasma lactate concentrations in these etorphine-immobilized moose were in the range reported for other immobilized wild ruminants. Decreasing induction time, which may be related to a more profound etorphine effect, and increasing snow depth possibly may increase plasma lactate concentrations in etorphine-immobilized moose.

  1. The potential influence of CO2, as an agent for euthanasia, on the pharmacokinetics of basic compounds in rodents.

    PubMed

    Angus, Derek W; Baker, James A; Mason, Rona; Martin, Iain J

    2008-02-01

    Rodent tissue distribution and pharmacokinetic studies were performed on basic compounds Org A and Org B in support of central nervous system drug discovery programs. A consistent observation from these studies was that drug concentrations in plasma obtained by cardiac puncture after CO(2) euthanasia were markedly higher compared with those from other sampling methods (serial sampling, isoflurane anesthesia, or cervical dislocation). Further investigations demonstrated that CO(2) euthanasia led to a reduction in blood pH in both rats and mice, which was not observed with the other sampling methods. The use of CO(2) euthanasia resulted in a decrease in the brain/plasma ratio of Org B, largely as a result of increased plasma concentrations. The pharmacokinetics of a basic drug, raloxifene, in rat were also influenced by sampling technique. CO(2) euthanasia before sampling, resulted in a 2- to 3-fold increase in the area under the drug concentration-time curve, a decrease in plasma clearance, and a decrease in the steady-state volume of distribution compared with isoflurane anesthesia. It is proposed that a decrease in the pH of blood relative to that of other tissues, as a consequence of CO(2) exposure, results in a redistribution of basic compounds out of the tissues, leading to higher concentrations in plasma.

  2. Carbon atom and cluster sputtering under low-energy noble gas plasma bombardment

    NASA Astrophysics Data System (ADS)

    Oyarzabal, E.; Doerner, R. P.; Shimada, M.; Tynan, G. R.

    2008-08-01

    Exit-angle resolved carbon atom and cluster (C2 and C3) sputtering yields are measured during different noble gas (Xe, Kr, Ar, Ne, and He) ion bombardments from a plasma, for low incident energies (75-225 eV). A quadrupole mass spectrometer (QMS) is used to detect the fraction of sputtered neutrals that is ionized in the plasma and to obtain the angular distribution by changing the angle between the target normal and the QMS aperture. A one-dimensional Monte Carlo code is used to simulate the interaction of the plasma and the sputtered particles in the region between the sample and the QMS. The effective elastic scattering cross sections of C, C2, and C3 with the different bombarding gas neutrals are obtained by varying the distance between the sample and the QMS and by performing a best fit of the simulation results to the experimental results. The total sputtering yield (C+C2+C3) for each bombarding gas is obtained from weight-loss measurements and the sputtering yield for C, C2, and C3 is then calculated from the integration of the measured angular distribution, taking into account the scattering and ionization of the sputtered particles between the sample and the QMS. We observe undercosine angular distributions of the sputtered atoms and clusters for all the studied bombarding gases and a clear decrease of the atom to cluster (C2 and C3) sputtering ratio as the incident ion mass increases, changing from a carbon atom preferential erosion for the lower incident ion masses (He, Ne, and Ar) to a cluster preferential erosion for the higher incident ion masses (Kr and Xe).

  3. EFFECTS OF LASER RADIATION ON MATTER. LASER PLASMA: Spectral and temporal characteristics of a laser plasma

    NASA Astrophysics Data System (ADS)

    Lipchak, A. I.; Solomonov, V. I.; Tel'nov, V. A.; Osipov, V. V.

    1995-04-01

    An experimental investigation was made of the spectral and temporal characteristics of a laser plasma formed by the interaction of a CO2 laser pulse with a target in atmospheric air. The results obtained indicate that the main role in the process of filling the excited states in a laser plasma is played by a recombination cascade and that both atoms and molecules of the atmospheric gases are excited. The result also show that a laser plasma can be used in spectroscopic analysis of multicomponent samples. The solution of the thermophysical problem of heating of a target by laser radiation supports the existing ideas on the process of formation of a plasma near the target surface in air.

  4. Expansion of an ultracold Rydberg plasma

    NASA Astrophysics Data System (ADS)

    Forest, Gabriel T.; Li, Yin; Ward, Edwin D.; Goodsell, Anne L.; Tate, Duncan A.

    2018-04-01

    We report a systematic experimental and numerical study of the expansion of ultracold Rydberg plasmas. Specifically, we have measured the asymptotic expansion velocities, v0, of ultracold neutral plasmas (UNPs) which evolve from cold, dense samples of Rydberg rubidium atoms using ion time-of-flight spectroscopy. From this, we have obtained values for the effective initial plasma electron temperature, Te ,0=mionv02/kB (where mion is the Rb+ ion mass), as a function of the original Rydberg atom density and binding energy, Eb ,i. We have also simulated numerically the interaction of UNPs with a large reservoir of Rydberg atoms to obtain data to compare with our experimental results. We find that for Rydberg atom densities in the range 107-109 cm-3, for states with principal quantum number n >40 , Te ,0 is insensitive to the initial ionization mechanism which seeds the plasma. In addition, the quantity kBTe ,0 is strongly correlated with the fraction of atoms which ionize, and is in the range 0.6 ×| Eb ,i|≲ kBTe ,0≲2.5 ×|Eb ,i| . On the other hand, plasmas from Rydberg samples with n ≲40 evolve with no significant additional ionization of the remaining atoms once a threshold number of ions has been established. The dominant interaction between the plasma electrons and the Rydberg atoms is one in which the atoms are deexcited, a heating process for electrons that competes with adiabatic cooling to establish an equilibrium where Te ,0 is determined by their Coulomb coupling parameter, Γe˜0.01 .

  5. Electrothermal vaporization of mineral acid solutions in inductively coupled plasma mass spectrometry: comparison with sample nebulization

    NASA Astrophysics Data System (ADS)

    Mora, Juan; Gras, Luis; van Veen, Eric H.; de Loos-Vollebregt, Margaretha T. C.

    1999-06-01

    The analytical behaviour of an electrothermal vaporization (ETV) device for the introduction of mineral acid solutions in inductively coupled plasma mass spectrometry (ICP-MS) was evaluated. Water, nitric acid, hydrochloric acid, perchloric acid and sulphuric acid in concentrations within the 0.05-1.0 mol l-1 range were studied. For all the acids tested, increasing the acid concentration increases the ion signal and deteriorates the precision. The magnitude of the signal enhancement depends on the analyte and on the acid considered. Acid solutions give rise to ion signals that are between 2 and 10 times higher than those with water. Among the acids tested, sulphuric acid provides the highest signals. The addition of palladium reduces matrix effects due to the acids and increases the signal in ETV ICP-MS. In comparison with conventional sample nebulization (CS), the ETV sample introduction system provides higher sensitivities (between 2 and 20 times higher) at the same acid concentration. The magnitude of this improvement is similar to that obtained with a microwave desolvation system (MWDS). The ETV sample introduction system gives rise to the lowest background signals from matrix-induced species. Due to this fact, the limits of detection (LODs) obtained for the isotopes affected by any interference are lower for ETV sample introduction than those obtained with the CS and the MWDS. For the isotopes that do not suffer from matrix-induced spectral interferences, the ETV gives rise to LODs higher than those obtained with the CS. For these isotopes the lowest LODs are obtained with MWDS.

  6. Plasma pentosidine levels measured by a newly developed method using ELISA in patients with chronic renal failure.

    PubMed

    Sanaka, Tsutomu; Funaki, Takenori; Tanaka, Toshihisa; Hoshi, Sayako; Niwayama, Jyun; Taitoh, Takashi; Nishimura, Hideki; Higuchi, Chieko

    2002-05-01

    The plasma pentosidine levels in patients with renal disease were measured by a simple method which was established for plasma and urinary pentosidine determinations. The method, which can be completed within a few hours, involves pretreating plasma with proteolytic enzyme (pronase) and measuring the concentration of pentosidine in the sample by ELISA using antipentosidine antibodies. The prepared antibodies showed no cross-reaction with the raw materials for pentosidine synthesis or with compounds having similar structures. SDS-PAGE indicated that the antibodies had a high purity. The reaction of the antibodies and keyhole limpet hemocyanin-pentosidine in the competitive ELISA system was inhibited by free pentosidine. Excellent standard curves for pentosidine determination were obtained. In actual measurements of clinical samples from patients, a good correlation (r = 0.9356) was obtained between the values measured by ELISA and HPLC. The plasma pentosidine level in patients with renal disease correlated significantly with plasma creatinine, urea nitrogen, beta2-microglobulin, and creatinine clearance, indicating its usefulness in evaluating the severity of renal disease. A significant elevation in plasma pentosidine levels was observed in mild renal dysfunction, whereas no significant increases in creatinine and urea nitrogen levels were detected, suggesting that the plasma pentosidine level is useful in the early diagnosis of beginning renal failure. In patients with chronic renal failure, no difference in plasma pentosidine levels was observed between diabetic nephropathy and chronic glomerulonephritis, while a significant correlation was observed with phosphatidylcholine hydroperoxide, suggesting the possibility that the plasma pentosidine level reflects injury due to oxidation. From these results, the quantitative measurement method developed by us is judged to be a superior innovation for measuring pentosidine in body fluids. The plasma pentosidine level may be useful for the early diagnosis of mild renal failure and to estimate the degree of the severity of renal diseases. Copyright 2002 S. Karger AG, Basel

  7. Alcohol: Friend or Foe? Alcoholic Beverage Hormesis for Cataract and Atherosclerosis is Related to Plasma Antioxidant Activity

    PubMed Central

    Prickett, Claire D.; Lister, E.; Collins, Michelle; Trevithick-Sutton, C. C.; Hirst, M.; Vinson, J. A.; Noble, E.; Trevithick, J. R.

    2004-01-01

    Objectives: To correlate the oxidative state of postabsorptive blood plasma after consumption of one or three drinks of different beverages with known J-shaped epidemiological risk curves. Design, interventions, and main outcome measures: Red wine, lager beer, stout (alcoholic and alcohol-free), with antioxidant activity, and an aqueous solution of alcohol were compared for the plasma antioxidant or pro-oxidant activity in human volunteers following consumption of one or three typical drinks containing equivalent amounts of alcohol (except for an alcohol-free stout used as a control for stout). Results: One drink of red wine, lager beer, or stout (5% alcohol v/v, and alcohol-free) significantly increased the average antioxidant activity in plasma samples obtained from volunteers averaged over 240 min. Three drinks of red wine, lager beer, or stout (5% alcohol v/v, and alcohol-free) significantly increased the average pro-oxidant activity in plasma samples obtained from volunteers averaged over 360 min. For a solution of alcohol, three drinks resulted in pro-oxidant plasma on average, whereas while one drink did not significantly affect the plasma oxidative status. A preliminary experiment in which two volunteers showed a significantly increased time to metabolize ethanol after ingestion resulted in elevated antioxidant activity in plasma for lager beer and red wine. Conclusions: One drink of red wine, beer, or stout provided equivalent increases in plasma antioxidant activity. Three drinks of red wine, beer, or stout provided equivalent increases in plasma pro-oxidant activity. This may explain, at least in part, the decreased risk of cataract and atherosclerosis from daily consumption of one drink of different types of alcoholic beverages as well as the increased risk from daily consumption of three drinks of alcoholic beverages. The plasma pro-oxidant activity appears to be due to ethanol metabolism, whereas the antioxidant activity may be due to the absorption of polyphenols in the beverages. PMID:19330151

  8. Effects of anesthesia and blood sampling techniques on plasma metabolites and corticosterone in the rat.

    PubMed

    Arnold, Myrtha; Langhans, Wolfgang

    2010-04-19

    Blood is routinely sampled from laboratory animals in biomedical research, and many of the commonly applied sampling techniques require anesthesia. Acute effects of many sampling and anesthesia procedures may confound the results, but those effects are incompletely characterized. We here compare the effects of four common anesthesia procedures (inhalation anesthesia with ether (EA) or isoflurane (IA) and intraperitoneal injection anesthesia with xylazin/ketamine (XKA) or medetomidine/midazolam/fentanyl (MMFA)) on plasma concentrations of glucose, lactate, non-esterified fatty acids (NEFAs), and corticosterone in blood obtained from a previously implanted jugular vein (JV) catheter with the effect of JV blood sampling from non-anesthetized, freely-moving rats (JV-NA). Also, we included in the comparison two other blood sampling procedures usually performed without anesthesia (NA), i.e., puncture of the saphenic vein (SV) and tail incision (TI). Whereas the control procedure (JV-NA) did not significantly affect any of the target parameters, plasma glucose increased from 14 (JV-IA) to 44 (JV-MMFA) % (all Ps=0.05 when compared with the control procedure) in all blood samples collected in anesthesia and was 12 and 14% lower (both Ps<0.05) in SV-NA and TI-NA samples, respectively. Plasma lactate increased from 74 (JV-IA) to 226% (SV-NA) (all Ps<0.05) with all sampling and anesthesia procedures except for JV-XKA and JV-MMF. Plasma NEFAs increased to 52% (P<0.05) with the TI-NA procedure and appeared to decrease with the JV-IA and JV-MMFA procedures (both Ps>0.05). Finally, only the JV-EA and the JV-MMFA procedures increased plasma corticosterone (+525 and +353%, respectively, both Ps< 0.05). The JV-IA and JV-XKA procedures appeared to increase it as well, but these differences did not reach statistical significance. Thus, anesthesia and blood sampling procedures can have profound acute effects on plasma metabolite and hormone concentrations. This must be considered for the design and interpretation of blood sampling experiments in laboratory animals. (c) 2010. Published by Elsevier Inc.

  9. Application of GC/MS-based metabonomic profiling in studying the lipid-regulating effects of Ginkgo biloba extract on diet-induced hyperlipidemia in rats

    PubMed Central

    Zhang, Qi; Wang, Guang-ji; A, Ji-ye; Wu, Di; Zhu, Ling-ling; Ma, Bo; Du, Yu

    2009-01-01

    Aim: To evaluate the lipid-regulating effects of extract from Ginkgo biloba leaves (EGB) using pharmacological methods and metabonomic profiling in a rat model of diet-induced hyperlipidemia. Methods: EGB was orally administered at a dose level of 40 mg/kg in both the EGB-prevention and -treatment groups. All rat samples obtained were examined for known and potential biomarkers and enzyme activity using commercial assay kits and GC/MS-based metabonomic profiling coupled with principal component analysis (PCA). Results: The data obtained from the assay kits indicated that EGB reduced total cholesterol and low density lipoprotein cholesterol levels and increased high density lipoprotein cholesterol levels in rat plasma obtained from both the EGB-prevention and –treatment groups compared with those of the diet-induced hyperlipidemia group. EGB also increased the activities of lipoprotein lipase and hepatic lipase and excretion of fecal bile acid in rats from the EGB-prevention and–treatment groups. Using GC/MS-based metabonomic analysis, more than 40 endogenous metabolites were identified in rat plasma. PCA of rat plasma samples obtained using GC/MS produced a distinctive separation of the four treatment groups and sampling points within each group. Metabolic changes during hyperlipidemia formation and improvement resulting from EGB treatment were definitively monitored with PCA score plots. Furthermore, elevated levels of sorbitol, tyrosine, glutamine and glucose, and decreased levels of citric acid, galactose, palmitic acid, arachidonic acid, acetic acid, cholesterol, butyrate, creatinine, linoleate, ornithine and proline, were observed in the plasma of rats treated with EGB. Conclusion: EGB exerts multi-directional lipid-lowering effects on the rat metabonome, including limitation of the absorption of cholesterol, inactivation of HMGCoA and favorable regulation of profiles of essential polyunsaturated fatty acid (EFA). Further experiments are warranted to explore the mechanisms of action underlying the lipid-regulating effects of EGB against hyperlipidemia. PMID:19960012

  10. Application of GC/MS-based metabonomic profiling in studying the lipid-regulating effects of Ginkgo biloba extract on diet-induced hyperlipidemia in rats.

    PubMed

    Zhang, Qi; Wang, Guang-ji; A, Ji-ye; Wu, Di; Zhu, Ling-ling; Ma, Bo; Du, Yu

    2009-12-01

    To evaluate the lipid-regulating effects of extract from Ginkgo biloba leaves (EGB) using pharmacological methods and metabonomic profiling in a rat model of diet-induced hyperlipidemia. EGB was orally administered at a dose level of 40 mg/kg in both the EGB-prevention and -treatment groups. All rat samples obtained were examined for known and potential biomarkers and enzyme activity using commercial assay kits and GC/MS-based metabonomic profiling coupled with principal component analysis (PCA). The data obtained from the assay kits indicated that EGB reduced total cholesterol and low density lipoprotein cholesterol levels and increased high density lipoprotein cholesterol levels in rat plasma obtained from both the EGB-prevention and -treatment groups compared with those of the diet-induced hyperlipidemia group. EGB also increased the activities of lipoprotein lipase and hepatic lipase and excretion of fecal bile acid in rats from the EGB-prevention and-treatment groups. Using GC/MS-based metabonomic analysis, more than 40 endogenous metabolites were identified in rat plasma. PCA of rat plasma samples obtained using GC/MS produced a distinctive separation of the four treatment groups and sampling points within each group. Metabolic changes during hyperlipidemia formation and improvement resulting from EGB treatment were definitively monitored with PCA score plots. Furthermore, elevated levels of sorbitol, tyrosine, glutamine and glucose, and decreased levels of citric acid, galactose, palmitic acid, arachidonic acid, acetic acid, cholesterol, butyrate, creatinine, linoleate, ornithine and proline, were observed in the plasma of rats treated with EGB. EGB exerts multi-directional lipid-lowering effects on the rat metabonome, including limitation of the absorption of cholesterol, inactivation of HMGCoA and favorable regulation of profiles of essential polyunsaturated fatty acid (EFA). Further experiments are warranted to explore the mechanisms of action underlying the lipid-regulating effects of EGB against hyperlipidemia.

  11. Plasma-based determination of inorganic contaminants in waste of electric and electronic equipment after microwave-induced combustion

    NASA Astrophysics Data System (ADS)

    Mello, Paola A.; Diehl, Lisarb O.; Oliveira, Jussiane S. S.; Muller, Edson I.; Mesko, Marcia F.; Flores, Erico M. M.

    2015-03-01

    A systematic study was performed for the determination of inorganic contaminants in polymeric waste from electrical and electronic equipment (EEE) for achieving an efficient digestion to minimize interferences in determination using plasma-based techniques. The determination of As, Br, Cd, Co, Cr, Cu, Ni, Pb, Sb, and Zn by inductively coupled plasma mass spectrometry (ICP-MS) and also by inductively coupled plasma optical emission spectrometry (ICP OES) was carried out after digestion using microwave-induced combustion (MIC). Arsenic and Hg were determined by flow-injection chemical vapor generation inductively coupled plasma mass spectrometry (FI-CVG-ICP-MS). Dynamic reaction cell inductively coupled plasma mass spectrometry (DRC-ICP-MS) with ammonia was also used for Cr determination. The suitability of MIC for digestion of sample masses up to 400 mg was demonstrated using microcrystalline cellulose as aid for combustion of polymers from waste of EEEs that usually contain flame retardants that impair the combustion. The composition and concentration of acid solutions (HNO3 or HNO3 plus HCl) were evaluated for metals and metalloids and NH4OH solutions were investigated for Br absorption. Accuracy was evaluated by comparison of results with those obtained using high pressure microwave-assisted wet digestion (HP-MAWD) and also by the analysis of certified reference material (CRM) of polymer (EC680k-low-density polyethylene). Bromine determination was only feasible using digestion by MIC once losses were observed when HP-MAWD was used. Lower limits of detection were obtained for all analytes using MIC (from 0.005 μg g- 1 for Co by ICP-MS up to 3.120 μg g-1 for Sb by ICP OES) in comparison to HP-MAWD due to the higher sample mass that can be digested (400 mg) and the use of diluted absorbing solutions. The combination of HNO3 and HCl for digestion showed to be crucial for quantitative recovery of some elements, as Cr and Sb. In addition, suitable agreement of Cr to CRM value was only obtained by mixing NH4Cl to samples before combustion. No statistical difference (95% confidence level) was observed between the results obtained for As, Cd, Co, Cr, Cu, Hg, Ni, Pb, Sb, and Zn by MIC and HP-MAWD methods. Agreement with certified values was better than 96% using MIC for all inorganic contaminants. Particularly for Br, MIC was the method of choice for digestion due to the possibility of using diluted alkaline solutions for analyte absorption. Based on the obtained results, MIC can be considered as a suitable method for digestion of polymers from waste of EEEs for further plasma based determination of inorganic contaminants.

  12. Spectral characteristics of plasma sheet ion and electron populations during undisturbed geomagnetic conditions

    NASA Technical Reports Server (NTRS)

    Christon, S. P.; Williams, D. J.; Mitchell, D. G.; Frank, L. A.; Huang, C. Y.

    1989-01-01

    The spectral characteristics of plasma-sheet ion and electron populations during periods of low geomagnetic activity were determined from the analysis of 127 one-hour average samples of central plasma sheet ions and electrons. Particle data from the ISEE-1 low-energy proton and electron differential energy analyzer and medium-energy particle instrument were combined to obtain differential energy spectra in the plasma sheet at geocentric radial distances above 12 earth radii. The relationships between the ion and electron spectral shapes and between the spectral shapes and the geomagnetic activity index were statistically investigated. It was found that the presence of interplanetary particle fluxes does not affect the plasma sheet particle spectral shape.

  13. Pericardial fluid is suitable as an alternative specimen for the measurement of β-hydroxybutyrate within 96 h after death.

    PubMed

    Mizutani, Tatsushi; Yoshimoto, Takashi; Ishii, Akira

    2018-05-21

    We examined postmortem β-hydroxybutyrate (BHB) levels in the body fluids obtained from 253 forensic autopsy cases whose causes of death were determined. Postmortem changes of BHB levels according to postmortem intervals (PMI) in various body fluids (plasma, urine, vitreous humor, and pericardial fluids) were investigated to determine appropriate alternative specimens as plasma samples. Our study has indicated the following points: 1) the BHB levels in plasma specimens from three sampling sites showed no significant differences, 2) postmortem changes of BHB levels in plasma and pericardial fluids could be negligible within 96 h PMI, while urine and vitreous humor BHB levels showed postmortem changes, and 3) pericardial fluid would thus be most suitable as an alternative to plasma in postmortem BHB level. We have also proposed that BHB levels could be applicable for the diagnosis of metabolic disorders in forensic autopsy. Copyright © 2018 Elsevier B.V. All rights reserved.

  14. Work function measurements during plasma exposition at conditions relevant in negative ion sources for the ITER neutral beam injection.

    PubMed

    Gutser, R; Wimmer, C; Fantz, U

    2011-02-01

    Cesium seeded sources for surface generated negative hydrogen ions are major components of neutral beam injection systems in future large-scale fusion experiments such as ITER. The stability and delivered current density depend highly on the work function during vacuum and plasma phases of the ion source. One of the most important quantities that affect the source performance is the work function. A modified photocurrent method was developed to measure the temporal behavior of the work function during and after cesium evaporation. The investigation of cesium exposed Mo and MoLa samples under ITER negative hydrogen ion based neutral beam injection relevant surface and plasma conditions showed the influence of impurities which result in a fast degradation when the plasma exposure or the cesium flux onto the sample is stopped. A minimum work function close to that of bulk cesium was obtained under the influence of the plasma exposition, while a significantly higher work function was observed under ITER-like vacuum conditions.

  15. Correlation of virus load in plasma and lymph node tissue in human immunodeficiency virus infection. INCAS Study Group. Italy, Netherlands, Canada, Australia, and (United) States.

    PubMed

    Harris, M; Patenaude, P; Cooperberg, P; Filipenko, D; Thorne, A; Raboud, J; Rae, S; Dailey, P; Chernoff, D; Todd, J; Conway, B; Montaner, J S

    1997-11-01

    The impact of long-term changes in plasma viremia, produced by effective combination antiretroviral therapy, on human immunodeficiency virus (HIV) burden within tissue reservoirs is unknown. Fifteen patients who had received at least 1 year of therapy with two or three drug combinations of zidovudine, didanosine, and nevirapine had suitable samples of lymph node tissue obtained by ultrasound-guided core needle biopsy. HIV RNA was extracted from homogenized tissue samples and quantitated using a modified branched DNA assay. Results were correlated with antiretroviral treatment effect on the basis of plasma virus load measurements over the preceding 12-18 months. A statistically significant negative correlation was observed between magnitude of treatment effect on plasma viremia and lymph node virus load. These data suggest that combinations of antiretroviral drugs that produce sustained suppression of plasma HIV RNA may also be able to reduce the virus burden in lymphoid tissues.

  16. Determination of selected fatty acids in dried sweat spot using gas chromatography with flame ionization detection.

    PubMed

    Kanďár, Roman; Drábková, Petra; Andrlová, Lenka; Kostelník, Adam; Čegan, Alexander

    2016-11-01

    A method is described for the determination of fatty acids in dried sweat spot and plasma samples using gas chromatography with flame ionization detection. Plasma and dried sweat spot samples were obtained from a group of blood donors. The sweat was collected from each volunteer during exercise. Sweat was spotted onto collection paper containing butylated hydroxytoluene. Fatty acids were derivatized with acetyl chloride in methanol to form methyl esters of fatty acids. The fatty acids in dried sweat spot samples treated with butylated hydroxytoluene and stored at -20°C were stable for 3 months. Our results indicate that sweat contains, among fatty acids with short chain, also fatty acids with long chain and unsaturated fatty acids. Linear relationships between percentage content of selected fatty acids in dried sweat spot and plasma were observed. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. Plasma cortisol levels and reactivation of latent Epstein-Barr virus in response to examination stress.

    PubMed

    Glaser, R; Pearl, D K; Kiecolt-Glaser, J K; Malarkey, W B

    1994-01-01

    In this study, we explored the possibility that glucocorticoid hormones, known to increase under stress, might be one component of the mechanism involved in induction of latent Epstein Barr virus (EBV). We obtained blood samples from 45 male medical students during examinations and approximately 3-4 weeks before the examinations (baseline) and measured antibody titers to EBV and plasma cortisol levels. We found reproducible changes in EBV, virus capsid antigen (VCA) antibody titers, with higher antibody titers observed in the examination blood samples consistent with the reactivation of latent virus. However, we found no evidence that day and night plasma cortisol values across the sampling points changed significantly from baseline to examinations. Therefore, academic stress did not elevate cortisol levels, but increases in EBV VCA antibody titers were still observed. The data suggest in these subjects that other neuropeptides or hormones were involved in the induction of latent EBV.

  18. Ex vivo spontaneous generation of 19-norandrostenedione and nandrolone detected in equine plasma and urine.

    PubMed

    Guan, Fuyu; Uboh, Cornelius E; Soma, Lawrence R; You, Youwen; Li, Xiaoqing; McDonnell, Sue

    2012-01-01

    19-Norandrostenedione (NAED) and nandrolone are anabolic-androgenic steroids (AASs). Nandrolone was regarded solely as a synthetic AAS until the 1980s when trace concentrations of apparently endogenous nandrolone were detected in urine samples obtained from intact male horses (stallions). Since then, its endogenous origin has been reported in boars and bulls; endogenous NAED and nandrolone have been identified in plasma and urine samples collected from stallions. More recently, however, it was suggested that NAED and nandrolone detected in urine samples from stallions are primarily artifacts due to the analytical procedure. The present study was undertaken to determine whether NAED and nandrolone detected in plasma and urine samples collected from stallions are truly endogenous or artifacts from sample processing. To answer this question, fresh plasma and urine samples from ≥8 stallions were analyzed for the two AASs, soon after collection, by liquid chromatography hyphenated to tandem mass spectrometry (LC-MS/MS). NAED and nandrolone were not detected in fresh plasma samples but detected in the same samples post storage. Concentrations of both AASs increased with storage time, and the increases were greater at a higher storage temperature (37°C versus 4°C, and ambient temperature versus 4°C). Although NAED was detected in some fresh stallion urine samples, its concentration (<407 pg/mL) was far lower (<0.4%) than that in the same samples post storage (at ambient temperature for 15 days). Nandrolone was not detected in most of fresh urine samples but detected in the same samples post storage. Based on these results, it is concluded that all NAED and nandrolone detected in stored plasma samples of stallions and most of them in the stored urine samples are not from endogenous origins but spontaneously generated during sample storage, most likely from spontaneous decarboxylation of androstenedione-19-oic acid and testosterone-19-oic acid. To our knowledge, it is the first time that all NAED and nandrolone detected in plasma of stallions and most of them detected in the urine have been shown to be spontaneously generated in vitro during sample storage. This finding would have significant implications with regard to the regulation of the two steroids in horse racing. Copyright © 2011 Elsevier Ltd. All rights reserved.

  19. Quantification of 11C-Laniquidar Kinetics in the Brain.

    PubMed

    Froklage, Femke E; Boellaard, Ronald; Bakker, Esther; Hendrikse, N Harry; Reijneveld, Jaap C; Schuit, Robert C; Windhorst, Albert D; Schober, Patrick; van Berckel, Bart N M; Lammertsma, Adriaan A; Postnov, Andrey

    2015-11-01

    Overexpression of the multidrug efflux transport P-glycoprotein may play an important role in pharmacoresistance. (11)C-laniquidar is a newly developed tracer of P-glycoprotein expression. The aim of this study was to develop a pharmacokinetic model for quantification of (11)C-laniquidar uptake and to assess its test-retest variability. Two (test-retest) dynamic (11)C-laniquidar PET scans were obtained in 8 healthy subjects. Plasma input functions were obtained using online arterial blood sampling with metabolite corrections derived from manual samples. Coregistered T1 MR images were used for region-of-interest definition. Time-activity curves were analyzed using various plasma input compartmental models. (11)C-laniquidar was metabolized rapidly, with a parent plasma fraction of 50% at 10 min after tracer injection. In addition, the first-pass extraction of (11)C-laniquidar was low. (11)C-laniquidar time-activity curves were best fitted to an irreversible single-tissue compartment (1T1K) model using conventional models. Nevertheless, significantly better fits were obtained using 2 parallel single-tissue compartments, one for parent tracer and the other for labeled metabolites (dual-input model). Robust K1 results were also obtained by fitting the first 5 min of PET data to the 1T1K model, at least when 60-min plasma input data were used. For both models, the test-retest variability of (11)C-laniquidar rate constant for transfer from arterial plasma to tissue (K1) was approximately 19%. The accurate quantification of (11)C-laniquidar kinetics in the brain is hampered by its fast metabolism and the likelihood that labeled metabolites enter the brain. Best fits for the entire 60 min of data were obtained using a dual-input model, accounting for uptake of (11)C-laniquidar and its labeled metabolites. Alternatively, K1 could be obtained from a 5-min scan using a standard 1T1K model. In both cases, the test-retest variability of K1 was approximately 19%. © 2015 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  20. Lactoferrin-Immobilized Surfaces onto Functionalized PLA Assisted by the Gamma-Rays and Nitrogen Plasma to Create Materials with Multifunctional Properties.

    PubMed

    Stoleru, Elena; Zaharescu, Traian; Hitruc, Elena Gabriela; Vesel, Alenka; Ioanid, Emil G; Coroaba, Adina; Safrany, Agnes; Pricope, Gina; Lungu, Maria; Schick, Christoph; Vasile, Cornelia

    2016-11-23

    Both cold nitrogen radiofrequency plasma and gamma irradiation have been applied to activate and functionalize the polylactic acid (PLA) surface and the subsequent lactoferrin immobilization. Modified films were comparatively characterized with respect to the procedure of activation and also with unmodified sample by water contact angle measurements, mass loss, X-ray photoelectron spectroscopy (XPS), attenuated total reflectance-Fourier transform infrared spectroscopy (ATR-FTIR), atomic force microscopy (AFM), and chemiluminescence measurements. All modified samples exhibit enhanced surface properties mainly those concerning biocompatibility, antimicrobial, and antioxidant properties, and furthermore, they are biodegradable and environmentally friendly. Lactoferrin deposited layer by covalent coupling using carbodiimide chemistry showed a good stability. It was found that the lactoferrin-modified PLA materials present significantly increased oxidative stability. Gamma-irradiated samples and lactoferrin-functionalized samples show higher antioxidant, antimicrobial, and cell proliferation activity than plasma-activated and lactoferrin-functionalized ones. The multifunctional materials thus obtained could find application as biomaterials or as bioactive packaging films.

  1. Carbonylated plasma proteins as potential biomarkers of obesity induced type 2 diabetes mellitus.

    PubMed

    Bollineni, Ravi Chand; Fedorova, Maria; Blüher, Matthias; Hoffmann, Ralf

    2014-11-07

    Protein carbonylation is a common nonenzymatic oxidative post-translational modification, which is often considered as biomarker of oxidative stress. Recent evidence links protein carbonylation also to obesity and type 2 diabetes mellitus (T2DM), though the protein targets of carbonylation in human plasma have not been identified. In this study, we profiled carbonylated proteins in plasma samples obtained from lean individuals and obese patients with or without T2DM. The plasma samples were digested with trypsin, carbonyl groups were derivatized with O-(biotinylcarbazoylmethyl)hydroxylamine, enriched by avidin affinity chromatography, and analyzed by RPC-MS/MS. Signals of potentially modified peptides were targeted in a second LC-MS/MS analysis to retrieve the peptide sequence and the modified residues. A total of 158 unique carbonylated proteins were identified, of which 52 were detected in plasma samples of all three groups. Interestingly, 36 carbonylated proteins were detected only in obese patients with T2DM, whereas 18 were detected in both nondiabetic groups. The carbonylated proteins originated mostly from liver, plasma, platelet, and endothelium. Functionally, they were mainly involved in cell adhesion, signaling, angiogenesis, and cytoskeletal remodeling. Among the identified carbonylated proteins were several candidates, such as VEGFR-2, MMP-1, argin, MKK4, and compliment C5, already connected before to diabetes, obesity and metabolic diseases.

  2. Breast-milk shedding of drug-resistant HIV-1 subtype C in women exposed to single-dose nevirapine.

    PubMed

    Lee, Esther J; Kantor, Rami; Zijenah, Lynn; Sheldon, Wayne; Emel, Lynda; Mateta, Patrick; Johnston, Elizabeth; Wells, Jennifer; Shetty, Avinash K; Coovadia, Hoosen; Maldonado, Yvonne; Jones, Samuel Adeniyi; Mofenson, Lynne M; Contag, Christopher H; Bassett, Mary; Katzenstein, David A

    2005-10-01

    Single-dose nevirapine reduces intrapartum human immunodeficiency virus 1 type (HIV-1) transmission but may also select for nonnucleoside reverse-transcriptase inhibitor (NNRTI) resistance in breast milk (BM) and plasma. Among 32 Zimbabwean women, median 8-week postpartum plasma and BM HIV-1 RNA levels were 4.57 and 2.13 log(10) copies/mL, respectively. BM samples from women with laboratory-diagnosed mastitis (defined as elevated BM Na(+) levels) were 5.4-fold more likely to have HIV-1 RNA levels above the median. BM RT sequences were not obtained for 12 women with BM HIV-1 RNA levels below the lower limit of detection of the assay used. In 20 paired BM and plasma samples, 65% of BM and 50% of plasma RT sequences had NNRTI-resistance mutations, with divergent mutation patterns.

  3. Quantitative analysis of [Dmt(1)]DALDA in ovine plasma by capillary liquid chromatography-nanospray ion-trap mass spectrometry.

    PubMed

    Wan, Haibao; Umstot, Edward S; Szeto, Hazel H; Schiller, Peter W; Desiderio, Dominic M

    2004-04-15

    The synthetic opioid peptide analog Dmt-D-Arg-Phe-Lys-NH(2) ([Dmt(1)]DALDA; [Dmt= 2',6'-dimethyltyrosine) is a highly potent and selective mu opioid-receptor agonist. A very sensitive and robust capillary liquid chromatography/nanospray ion-trap (IT) mass spectrometry method has been developed to quantify [Dmt(1)]DALDA in ovine plasma, using deuterated [Dmt(1)]DALDA as the internal standard. The standard MS/MS spectra of d(0)- and d(5)-[Dmt(1)]DALDA were obtained, and the collision energy was experimentally optimized to 25%. The product ion [ M + 2H-NH(3)](2+) (m/z 312.2) was used to identify and to quantify the synthetic opioid peptide analog in ovine plasma samples. The MS/MS detection sensitivity for [Dmt(1)]DALDA was 625 amol. A calibration curve was constructed, and quantitative analysis was performed on a series of ovine plasma samples.

  4. Effect of Rapid Thermal Annealing on the Electrical Characteristics of ZnO Thin-Film Transistors

    NASA Astrophysics Data System (ADS)

    Remashan, Kariyadan; Hwang, Dae-Kue; Park, Seong-Ju; Jang, Jae-Hyung

    2008-04-01

    Thin-film transistors (TFTs) with a bottom-gate configuration were fabricated with an RF magnetron sputtered undoped zinc oxide (ZnO) channel layer and plasma-enhanced chemical vapor deposition (PECVD) grown silicon nitride as a gate dielectric. Postfabrication rapid thermal annealing (RTA) and subsequent nitrous oxide (N2O) plasma treatment were employed to improve the performance of ZnO TFTs in terms of on-current and on/off current ratio. The RTA treatment increases the on-current of the TFT significantly, but it also increases its off-current. The off-current of 2×10-8 A and on/off current ratio of 3×103 obtained after the RTA treatment were improved to 10-10 A and 105, respectively, by the subsequent N2O plasma treatment. The better device performance can be attributed to the reduction of oxygen vacancies at the top region of the channel due to oxygen incorporation from the N2O plasma. X-ray photoelectron spectroscopy (XPS) analysis of the TFT samples showed that the RTA-treated ZnO surface has more oxygen vacancies than as-deposited samples, which results in the increased drain current. The XPS study also showed that the subsequent N2O plasma treatment reduces oxygen vacancies only at the surface of ZnO so that the better off-current and on/off current ratio can be obtained.

  5. Plasma and white adipose tissue lipid composition in marmots.

    PubMed

    Florant, G L; Nuttle, L C; Mullinex, D E; Rintoul, D A

    1990-05-01

    White adipose tissue biopsies and plasma samples were obtained from hibernating yellow-bellied marmots (Marmota flaviventris) maintained in the laboratory. In addition, biopsies and plasma samples were obtained from normothermic animals in the field and laboratory. Measurement of plasma free fatty acid (FA) levels indicated that winter laboratory animals exhibited increased lipolysis. Additionally, analysis of white adipose tissue triacylglycerol revealed that the FA composition of the storage fat in animals maintained on the standard laboratory diet is remarkably simple and uniform between different adipose depots in the same animal. Three FAs (palmitic, oleic, and linoleic acids) made up greater than 95% of the total. Triene (alpha-linolenate) was found in newly captured animals, but the percentage of this FA decreased rapidly when the animals were maintained on the standard laboratory diet. Throughout the hibernation season (October to April), white adipose tissue-saturated FA percentage decreased, monoene percentage remained constant, and diene percentage increased. Analysis of plasma FA composition suggested that these animals tended to metabolize saturated FAs from stored lipid during hibernation and that dienes were mobilized briefly after the last arousal from hibernation in spring. From these observations, we hypothesize that marmots preferentially metabolize saturated fats during the hibernation period and that essential FAs of the omega 6 series tend to be metabolized more slowly than other FAs. These characteristics suggest that marmots are a valuable animal model in which to study lipid metabolism.

  6. Quantitative determination of galantamine in human plasma by sensitive liquid chromatography-tandem mass spectrometry using loratadine as an internal standard.

    PubMed

    Nirogi, Ramakrishna V S; Kandikere, Vishwottam N; Mudigonda, Koteshwara; Maurya, Santosh

    2007-02-01

    A simple, rapid, sensitive, and selective liquid chromatography-tandem mass spectrometry method is developed and validated for the quantitation of galantamine, an acetylcholinesterase inhibitor in human plasma, using a commercially available compound, loratadine, as the internal standard. Following liquid-liquid extraction, the analytes are separated using an isocratic mobile phase on a reverse-phase C18 column and analyzed by mass spectrometry in the multiple reaction monitoring mode using the respective (M+H)+ ions, m/z 288 to 213 for galantamine and m/z 383 and 337 for the internal standard. The assay exhibit a linear dynamic range of 0.5-100 ng/mL for galantamine in human plasma. The lower limit of quantitation is 0.5 ng/mL, with a relative standard deviation of less than 8%. Acceptable precision and accuracy are obtained for concentrations over the standard curve range. A run time of 2.5 min for each sample makes it possible to analyze more than 400 human plasma samples per day. The validated method is successfully used to analyze human plasma samples for application in pharmacokinetic, bioavailability, or bioequivalence studies.

  7. Analytical and clinical performance of the Hologic Aptima HCV Quant Dx Assay for the quantification of HCV RNA in plasma samples.

    PubMed

    Schønning, Kristian; Pedersen, Martin Schou; Johansen, Kim; Landt, Bodil; Nielsen, Lone Gilmor; Weis, Nina; Westh, Henrik

    2017-10-01

    Chronic hepatitis C virus (HCV) infection can be effectively treated with directly acting antiviral (DAA) therapy. Measurement of HCV RNA is used to evaluate patient compliance and virological response during and after treatment. To compare the analytical performance of the Aptima HCV Quant Dx Assay (Aptima) and the COBAS Ampliprep/COBAS TaqMan HCV Test v2.0 (CAPCTMv2) for the quantification of HCV RNA in plasma samples, and compare the clinical utility of the two tests in patients undergoing treatment with DAA therapy. Analytical performance was evaluated on two sets of plasma samples: 125 genotyped samples and 172 samples referred for quantification of HCV RNA. Furthermore, performance was evaluated using dilutions series of four samples containing HCV genotype 1a, 2b, 3a, and 4a, respectively. Clinical utility was evaluated on 118 plasma samples obtained from 13 patients undergoing treatment with DAAs. Deming regression of results from 187 plasma samples with HCV RNA >2 Log IU/mL indicated that the Aptima assay quantified higher than the CAPCTMv2 test for HCV RNA >4.9 Log IU/mL. The linearity of the Aptima assay was excellent across dilution series of four HCV genotypes (slope of the regression line: 1.00-1.02). The Aptima assay detected significantly more replicates below targeted 2 Log IU/mL than the CAPCTMv2 test, and yielded clearly interpretable results when used to analyze samples from patients treated with DAAs. The analytical performance of the Aptima assay makes it well suited for monitoring patients with chronic HCV infection undergoing antiviral treatment. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Calibration approach for extremely variable laser induced plasmas and a strategy to reduce the matrix effect in general

    NASA Astrophysics Data System (ADS)

    Lazic, V.; De Ninno, A.

    2017-11-01

    The laser induced plasma spectroscopy was applied on particles attached on substrate represented by a silica wafer covered with a thin oil film. The substrate itself weakly interacts with a ns Nd:YAG laser (1064 nm) while presence of particles strongly enhances the plasma emission, here detected by a compact spectrometer array. Variations of the sample mass from one laser spot to another exceed one order of magnitude, as estimated by on-line photography and the initial image calibration for different sample loadings. Consequently, the spectral lines from particles show extreme intensity fluctuations from one sampling point to another, between the detection threshold and the detector's saturation in some cases. In such conditions the common calibration approach based on the averaged spectra, also when considering ratios of the element lines i.e. concentrations, produces errors too large for measuring the sample compositions. On the other hand, intensities of an analytical and the reference line from single shot spectra are linearly correlated. The corresponding slope depends on the concentration ratio and it is weakly sensitive to fluctuations of the plasma temperature inside the data set. A use of the slopes for constructing the calibration graphs significantly reduces the error bars but it does not eliminate the point scattering caused by the matrix effect, which is also responsible for large differences in the average plasma temperatures among the samples. Well aligned calibration points were obtained after identifying the couples of transitions less sensitive to variations of the plasma temperature, and this was achieved by simple theoretical simulations. Such selection of the analytical lines minimizes the matrix effect, and together with the chosen calibration approach, allows to measure the relative element concentrations even in highly unstable laser induced plasmas.

  9. Uranium plasma emission at gas-core reaction conditions

    NASA Technical Reports Server (NTRS)

    Williams, M. D.; Jalufka, N. W.; Hohl, F.; Lee, J. H.

    1976-01-01

    The results of uranium plasma emission produced by two methods are reported. For the first method a ruby laser was focused on the surface of a pure U-238 sample to create a plasma plume with a peak plasma density of about 10 to the 20th power/cu cm and a temperature of about 38,600 K. The absolute intensity of the emitted radiation, covering the range from 300 to 7000 A was measured. For the second method, the uranium plasma was produced in a 20 kilovolt, 25 kilojoule plasma-focus device. The 2.5 MeV neutrons from the D-D reaction in the plasma focus are moderated by polyethylene and induce fissions in the U-235. Spectra of both uranium plasmas were obtained over the range from 30 to 9000 A. Because of the low fission yield the energy input due to fissions is very small compared to the total energy in the plasma.

  10. Ultra-high performance liquid chromatographic determination of levofloxacin in human plasma and prostate tissue with use of experimental design optimization procedures.

    PubMed

    Szerkus, O; Jacyna, J; Wiczling, P; Gibas, A; Sieczkowski, M; Siluk, D; Matuszewski, M; Kaliszan, R; Markuszewski, M J

    2016-09-01

    Fluoroquinolones are considered as gold standard for the prevention of bacterial infections after transrectal ultrasound guided prostate biopsy. However, recent studies reported that fluoroquinolone- resistant bacterial strains are responsible for gradually increasing number of infections after transrectal prostate biopsy. In daily clinical practice, antibacterial efficacy is evaluated only in vitro, by measuring the reaction of bacteria with an antimicrobial agent in culture media (i.e. calculation of minimal inhibitory concentration). Such approach, however, has no relation to the treated tissue characteristics and might be highly misleading. Thus, the objective of this study was to develop, with the use of Design of Experiments approach, a reliable, specific and sensitive ultra-high performance liquid chromatography- diode array detection method for the quantitative analysis of levofloxacin in plasma and prostate tissue samples obtained from patients undergoing prostate biopsy. Moreover, correlation study between concentrations observed in plasma samples vs prostatic tissue samples was performed, resulting in better understanding, evaluation and optimization of the fluoroquinolone-based antimicrobial prophylaxis during transrectal ultrasound guided prostate biopsy. Box-Behnken design was employed to optimize chromatographic conditions of the isocratic elution program in order to obtain desirable retention time, peak symmetry and resolution of levofloxacine and ciprofloxacine (internal standard) peaks. Fractional Factorial design 2(4-1) with four center points was used for screening of significant factors affecting levofloxacin extraction from the prostatic tissue. Due to the limited number of tissue samples the prostatic sample preparation procedure was further optimized using Central Composite design. Design of Experiments approach was also utilized for evaluation of parameter robustness. The method was found linear over the range of 0.030-10μg/mL for human plasma and 0.300-30μg/g for human prostate tissue samples. The intra-day and inter-day variability for levofloxacine from both plasma and prostate samples were less than 10%, with accuracies between 93 and 108% of the nominal values. The limit of detection and the limit of quantification for human plasma were 0.01μg/mL and 0.03μg/mL, respectively. For the prostate tissue, the limit of detection and the limit of quantification were 0.1μg/g and 0.3μg/g, respectively. The average recoveries of levofloxacin were in the range from 99 to 106%. Also, the method fulfills requirements of robustness what was determined and proved by Design of Experiments. The developed method was successfully applied to examine prostate tissue and plasma samples from 140 hospitalized patients enrolled into the clinical study, 12h after oral administration of LVF at a dose of 500mg. The mean (±SD) LVF concentration in prostate was 6.22±3.52μg/g and in plasma 2.54±1.14μg/mL. Due to simplicity of the method and relative small amount of sample needed for the assay, the method can be applied in clinical practice for monitoring of LVF concentrations in plasma and prostate gland. Copyright © 2016 Elsevier B.V. All rights reserved.

  11. Increasing Wear Resistance of Titanium Alloys by Anode Plasma Electrolytic Saturation with Interstitial Elements

    NASA Astrophysics Data System (ADS)

    Belkin, P. N.; Kusmanov, S. A.; Dyakov, I. G.; Silkin, S. A.; Smirnov, A. A.

    2017-05-01

    In our previous studies, we have shown that anode plasma electrolytic saturation of titanium alloys with nitrogen and carbon can improve their tribological properties. Obtained structure containing oxide layer and solid solution of diffused element in titanium promotes the enhancement of running-in ability and the decrease in the wear rate in some special cases. In this paper, further investigations are reported regarding the tribological properties of alpha- and beta-titanium alloys in wear test against hardened steel (50 HRC) disk using pin-on-disk geometry and balls of Al2O3 (6.25 mm in diameter) or bearing steel (9.6 mm in diameter) with ball-on-plate one and normal load from 5 to 209 N. Reproducible results were obtained under testing samples treated by means of the plasma electrolytic nitriding (PEN) with the mechanical removal of the oxide layer. Friction coefficient of nitrided samples is 0.5-0.9 which is somewhat higher than that for untreated one (0.48-0.75) during dry sliding against Al2O3 ball. An increase in the sliding speed results in the polishing of nitrided samples and reduction of their wear rate by 60 times. This result is obtained for 5 min at 850 °C using PEN in electrolyte containing 5 wt.% ammonia and 10 wt.% ammonium chloride followed by quenching in solution. Optical microscope was employed to assist in the evaluation of the wear behavior. Sizes of wear tracks were measured by profilometer TR200.

  12. Plasma choline and betaine and their relation to plasma homocysteine in normal pregnancy.

    PubMed

    Velzing-Aarts, Francien V; Holm, Pål I; Fokkema, M Rebecca; van der Dijs, Fey P; Ueland, Per M; Muskiet, Frits A

    2005-06-01

    Plasma concentrations of total homocysteine (tHcy) decrease during pregnancy. This reduction has been investigated in relation to folate status, but no study has addressed the possible role of betaine and its precursor choline. We investigated the courses of plasma choline and betaine during normal human pregnancy and their relations to plasma tHcy. Blood samples were obtained monthly; the initial samples were taken at gestational week (GW) 9, and the last samples were taken approximately 3 mo postpartum. The study population comprised 50 women of West African descent. Most of the subjects took folic acid irregularly. Plasma choline (geometric x; 95% reference interval) increased continuously during pregnancy, from 6.6 (4.5, 9.7) micromol/L at GW 9 to 10.8 (7.4, 15.6) micromol/L at GW 36. Plasma betaine decreased in the first half of pregnancy, from 16.3 (8.6, 30.8) micromol/L at GW 9 to 10.3 (6.6, 16.2) micromol/L at GW 20 and remained constant thereafter. We confirmed a reduction in plasma tHcy, and the lowest concentration was found in the second trimester. From GW 16 onward, an inverse relation between plasma tHcy and betaine was observed. Multiple regression analysis showed that plasma betaine was a strong predictor of plasma tHcy from GW 20 onward. The steady increase in choline throughout gestation may ensure choline availability for placental transfer with subsequent use by the growing fetus. Betaine becomes a strong predictor of tHcy during the course of pregnancy. Both of these findings emphasize the importance of choline and betaine status during normal human pregnancy.

  13. A sensitive LC-MS/MS method for the simultaneous determination of amoxicillin and ambroxol in human plasma with segmental monitoring.

    PubMed

    Dong, Xin; Ding, Li; Cao, Xiaomei; Jiang, Liyuan; Zhong, Shuisheng

    2013-04-01

    Amoxicillin (AMO) degrades in plasma at room temperature and readily undergoes hydrolysis by the plasma amidase. In this paper, a novel, rapid and sensitive LC-MS/MS method operated in segmental and multiple reaction monitoring has been developed for the simultaneous determination of amoxicillin and ambroxol in human plasma. The degradation of amoxicillin in plasma was well prevented by immediate addition of 20 μL glacial acetic acid to 200 μL aliquot of freshly collected plasma samples before storage at -80°C. The sensitivity of the method was improved with segmental monitoring of the analytes, and lower limits of quantitation of 0.5 ng/mL for ambroxol and 5 ng/mL for amoxicillin were obtained. The sensitivity of our method was five times better than those of the existing methods. Furthermore, the mass response saturation problem with amoxicillin was avoided by diluting the deproteinized plasma samples with water before injection into the LC-MS/MS system. The method was successfully employed in a pharmacokinetic study of the compound amoxicillin and ambroxol hydrochloride tablets. Copyright © 2012 John Wiley & Sons, Ltd.

  14. Impression of plasma voltage on growth of α-V2O5 nanostructured thin films

    NASA Astrophysics Data System (ADS)

    Sharma, Rabindar Kumar; Kumar, Prabhat; Reddy, G. B.

    2015-06-01

    In this communication, we synthesized vanadium pentoxide (α-V2O5) nanostructured thin films (NSTs) accompanied with nanoflakes/ nanoplates on the Ni-coated glass substrates employing plasma assisted sublimation process (PASP) as a function of plasma voltage (Vp). The effect of plasma voltage on structural, morphological, compositional, and vibrational properties have been studied systematically. The structural analysis divulged that all films deposited at different Vp have pure orthorhombic phase, no impurity phase is detected under resolution limit of XRD and XPS. The morphological studies of samples is carried out by SEM, revealed that features as well as alignment of V2O5 NSTs is greatly monitored by Vp and the film possessing the best features is obtained at 2500volt. In addition, XPS results reveal that V5+ oxidation state is the most prominent state in sample V2, which represents better stoichiometric nature of film. The vibrational study of all samples is performed by FTIR and strongly support the XRD observations. All the results are in consonance with each other.

  15. Interactions between ecology, demography, capture stress, and profiles of corticosterone and glucose in a free-living population of Australian freshwater crocodiles.

    PubMed

    Jessop, Tim S; Tucker, Anton D; Limpus, Colin J; Whittier, Joan M

    2003-06-01

    In this study we examined three aspects pertaining to adrenocortical responsiveness in free-ranging Australian freshwater crocodiles (Crocodylus johnstoni). First, we examined the ability of freshwater crocodiles to produce corticosterone in response to a typical capture-stress protocol. A second objective addressed the relationship between capture stress, plasma glucose and corticosterone. Next we examined if variation in basal and capture-stress-induced levels of plasma corticosterone was linked to ecological or demographic factors for individuals in this free-ranging population. Blood samples obtained on three field trips were taken from a cross-sectional sample of the population. Crocodiles were bled once during four time categories at 0, 0.5, 6, and 10h post-capture. Plasma corticosterone increased significantly with time post-capture. Plasma glucose also significantly increased with duration of capture-stress and exhibited a positive and significant relationship with plasma corticosterone. Significant variation in basal or stress induced levels of corticosterone in crocodiles was not associated with any ecological or demographic factors including sex, age class or the year of capture that the crocodiles were sampled from. However, three immature males had basal levels of plasma corticosterone greater than 2 standard deviations above the mean. While crocodiles exhibited a pronounced adrenocortical and hyperglycaemic response to capture stress, limited variation in adrenocortical responsiveness due to ecological and demographic factors was not evident. This feature could arise in part because this population was sampled during a period of environmental benigness.

  16. Optical Emission Studies of Copper Plasma Induced Using Infrared Transversely Excited Atmospheric (IR TEA) Carbon Dioxide Laser Pulses.

    PubMed

    Momcilovic, Milos; Kuzmanovic, Miroslav; Rankovic, Dragan; Ciganovic, Jovan; Stoiljkovic, Milovan; Savovic, Jelena; Trtica, Milan

    2015-04-01

    Spatially resolved, time-integrated optical emission spectroscopy was applied for investigation of copper plasma produced by a nanosecond infrared (IR) transversely excited atmospheric (TEA) CO2 laser, operating at 10.6 μm. The effect of surrounding air pressure, in the pressure range 0.1 to 1013 mbar, on plasma formation and its characteristics was investigated. A linear dependence of intensity threshold for plasma formation on logarithm of air pressure was found. Lowering of the air pressure reduces the extent of gas breakdown, enabling better laser-target coupling and thus increases ablation. Optimum air pressure for target plasma formation was 0.1 mbar. Under that pressure, the induced plasma consisted of two clearly distinguished and spatially separated regions. The maximum intensity of emission, with sharp and well-resolved spectral lines and negligibly low background emission, was obtained from a plasma zone 8 mm from the target surface. The estimated excitation temperature in this zone was around 7000 K. The favorable signal to background ratio obtained in this plasma region indicates possible analytical application of TEA CO2 laser produced copper plasma. Detection limits of trace elements present in the Cu sample were on the order of 10 ppm (parts per million). Time-resolved measurements of spatially selected plasma zones were used to find a correlation between the observed spatial position and time delay.

  17. The influence of seafloor hydrothermal activity on major and trace elements of the sediments from the South Mid-Atlantic Ridge

    NASA Astrophysics Data System (ADS)

    Huang, Xin; Chen, Shuai; Zeng, Zhigang; Pu, Xiaoqiang; Hou, Qinghua

    2017-10-01

    Sediment samples obtained from the South Mid-Atlantic Ridge were analyzed for the major and trace elements by inductively coupled plasma atomic emission spectroscopy and inductively coupled plasma mass spectrometry. Results revealed that the contents of elements (e.g., Fe, Mn, Cu, Zn, V, Co) were high in samples 22V-TVG10 and 26V-TVG05 from the sites near the hydrothermal areas, and low in sample 22V-TVG14, which was collected far from the hydrothermal areas. The contents of Ca, Sr and Ba in the samples showed opposite trends. A positive correlation between the concentrations of metallic elements (Cu, Zn, Co, Ni, Pb, V) and Fe in the samples were observed. These results are consistent with chemical evolution of the dispersing hydrothermal plume.

  18. Plasma fluctuation in estradiol-17β and bone resorption markers around parturition in dairy cows

    PubMed Central

    DEVKOTA, Bhuminad; TAKAHASHI, Masahiro; SATO, Saori; SASAKI, Kouya; UEKI, Atsushi; OSAWA, Takeshi; TAKAHASHI, Masahiro; YAMAGISHI, Norio

    2015-01-01

    Blood samples were obtained sequentially from 10 dairy cows around the time of parturition to assess plasma fluctuations in estradiol-17β (E2) levels in association with those of several bone resorption markers. Plasma E2 concentration increased sharply a few days prepartum and decreased quickly after parturition. In terms of bone resorption markers, the plasma level of tartrate-resistant acid phosphatase isoform 5b (TRAP5b) rose significantly, commencing 1 week prepartum, and was maintained at this level to a few days postpartum. The plasma concentration of carboxyterminal collagen cross-links of type-I collagen (CTx) increased significantly after parturition. These observations suggest that osteoclast-mediated bone resorption was activated after parturition when plasma E2 concentrations decreased. PMID:25755022

  19. Plasma fluctuation in estradiol-17β and bone resorption markers around parturition in dairy cows.

    PubMed

    Devkota, Bhuminad; Takahashi, Masahiro; Sato, Saori; Sasaki, Kouya; Ueki, Atsushi; Osawa, Takeshi; Takahashi, Masahiro; Yamagishi, Norio

    2015-07-01

    Blood samples were obtained sequentially from 10 dairy cows around the time of parturition to assess plasma fluctuations in estradiol-17β (E2) levels in association with those of several bone resorption markers. Plasma E2 concentration increased sharply a few days prepartum and decreased quickly after parturition. In terms of bone resorption markers, the plasma level of tartrate-resistant acid phosphatase isoform 5b (TRAP5b) rose significantly, commencing 1 week prepartum, and was maintained at this level to a few days postpartum. The plasma concentration of carboxyterminal collagen cross-links of type-I collagen (CTx) increased significantly after parturition. These observations suggest that osteoclast-mediated bone resorption was activated after parturition when plasma E2 concentrations decreased.

  20. Plasma Discharge with Different Electrode Diameters for Reducing Methylene Blue Concentration

    NASA Astrophysics Data System (ADS)

    Rasyidah, H.; Kusumandari; Saraswati, T. E.; Anwar, M.

    2018-03-01

    Recently, plasma technology has gained attention since it overcomes the shortcomings of water treatment. This research studies the effect of electrode diameter of plasma discharge reactors on the concentration reduction of methylene blue as an organic solution. The plasma discharge reactor was built from a pair of stainless needle electrodes connected with high-AC voltage. The electrodes were placed approximately 2 mm above the solution and stirred at 5.5 rpm. The diameters of the electrodes were 2, 3.2 and 4 mm. The times for plasma treatment were set at 2, 4, 6, 8 and 10 min. Absorbance, temperature and pH of the solution were measured to know the effects of electrode diameter of the plasma reactor. Absorbance and pH significantly decreased after plasma treatment. The best of the absorbance reduction were obtained when the sample was treated under plasma discharge using the smallest diameter electrodes for 8-10 min.

  1. Laser induced breakdown spectroscopy (LIBS) as a rapid tool for material analysis

    NASA Astrophysics Data System (ADS)

    Hussain, T.; Gondal, M. A.

    2013-06-01

    Laser induced breakdown spectroscopy (LIBS) is a novel technique for elemental analysis based on laser-generated plasma. In this technique, laser pulses are applied for ablation of the sample, resulting in the vaporization and ionization of sample in hot plasma which is finally analyzed by the spectrometer. The elements are identified by their unique spectral signatures. LIBS system was developed for elemental analysis of solid and liquid samples. The developed system was applied for qualitative as well as quantitative measurement of elemental concentration present in iron slag and open pit ore samples. The plasma was generated by focusing a pulsed Nd:YAG laser at 1064 nm on test samples to study the capabilities of LIBS as a rapid tool for material analysis. The concentrations of various elements of environmental significance such as cadmium, calcium, magnesium, chromium, manganese, titanium, barium, phosphorus, copper, iron, zinc etc., in these samples were determined. Optimal experimental conditions were evaluated for improving the sensitivity of developed LIBS system through parametric dependence study. The laser-induced breakdown spectroscopy (LIBS) results were compared with the results obtained using standard analytical technique such as inductively couple plasma emission spectroscopy (ICP). Limit of detection (LOD) of our LIBS system were also estimated for the above mentioned elements. This study demonstrates that LIBS could be highly appropriate for rapid online analysis of iron slag and open pit waste.

  2. Development of a laser ablation-hollow cathode glow discharge emission source and the application to the analysis of steel samples.

    PubMed

    Naeem, Tariq M; Matsuta, Hideyuki; Wagatsuma, Kazuaki

    2004-12-01

    A novel atomic emission spectrometry comprising laser ablation as a sampling source and hollow cathode plasma for the excitation of ablated sample atoms is proposed. In this arrangement, a conventional Grimm-type discharge lamp is employed, but the polarity of the power supply is reversed so that the cylindrical hollow tube acts as a cathode and the glow discharge plasma is produced within this tube. A laser is irradiated to introduce sample atoms into the discharge plasma. Ablated atoms are excited by collisions with electrons and gas species, and emit characteristic radiation upon de-excitation. The experiments were conducted only in an atmosphere of helium gas so as to avoid a rapid erosion of the cathode hollow tube. Phase-sensitive detection with a lock-in amplifier was utilized to reject the continuous background emission of the plasma gas and emissions of sputtered atoms from the tube material. The unique feature of this technique is that the sampling and excitation processes can be controlled independently. The proposed technique was employed for the determination of Cr, Mn, and Ni in low-alloyed steel samples. The obtained concentrations are in good agreement with the reported values. The relative standard deviation (RSD), a measure of the analytical precision, was estimated to be 2-9% for Cr, 3-4% for Mn, and 4-11% for Ni determination.

  3. Degradation resistance of 3Y-TZP ceramics sintered using spark plasma sintering

    NASA Astrophysics Data System (ADS)

    Chintapalli, R.; Marro, F. G.; Valle, J. A.; Yan, H.; Reece, M. J.; Anglada, M.

    2009-09-01

    Commercially available tetragonal zirconia powder doped with 3 mol% of yttria has been sintered using spark plasma sintering (SPS) and has been investigated for its resistance to hydrothermal degradation. Samples were sintered at 1100, 1150, 1175 and 1600 °C at constant pressure of 100 MPa and soaking for 5 minutes, and the grain sizes obtained were 65, 90, 120 and 800 nm, respectively. Samples sintered conventionally with a grain size of 300 nm were also compared with samples sintered using SPS. Finely polished samples were subjected to artificial degradation at 131 °C for 60 hours in vapour in auto clave under a pressure of 2 bars. The XRD studies show no phase transformation in samples with low density and small grain size (<200 nm), but significant phase transformation is seen in dense samples with larger grain size (>300 nm). Results are discussed in terms of present theories of hydrothermal degradation.

  4. Green and Fast Laser Fusion Technique for Bulk Silicate Rock Analysis by Laser Ablation-Inductively Coupled Plasma Mass Spectrometry.

    PubMed

    Zhang, Chenxi; Hu, Zhaochu; Zhang, Wen; Liu, Yongsheng; Zong, Keqing; Li, Ming; Chen, Haihong; Hu, Shenghong

    2016-10-18

    Sample preparation of whole-rock powders is the major limitation for their accurate and precise elemental analysis by laser ablation inductively-coupled plasma mass spectrometry (ICPMS). In this study, a green, efficient, and simplified fusion technique using a high energy infrared laser was developed for major and trace elemental analysis. Fusion takes only tens of milliseconds for each sample. Compared to the pressed pellet sample preparation, the analytical precision of the developed laser fusion technique is higher by an order of magnitude for most elements in granodiorite GSP-2. Analytical results obtained for five USGS reference materials (ranging from mafic to intermediate to felsic) using the laser fusion technique generally agree with recommended values with discrepancies of less than 10% for most elements. However, high losses (20-70%) of highly volatile elements (Zn and Pb) and the transition metal Cu are observed. The achieved precision is within 5% for major elements and within 15% for most trace elements. Direct laser fusion of rock powders is a green and notably simple method to obtain homogeneous samples, which will significantly accelerate the application of laser ablation ICPMS for whole-rock sample analysis.

  5. Pavlovian autoshaping procedures increase plasma corticosterone levels in rats.

    PubMed

    Tomie, Arthur; Silberman, Yuval; Williams, Kayon; Pohorecky, Larissa A

    2002-06-01

    Pavlovian autoshaping conditioned responses (CRs) are complex sequences of conditioned stimulus (CS)-directed skeletal-motor responses that are elicited by CS objects predictive of food unconditioned stimulus (US). Autoshaping CRs are observed under conditions known to be conducive to elevations in plasma corticosterone levels, as, for example, in response to the eating of food as well as in response to signals predictive of food. Two experiments investigated the relationships between Pavlovian autoshaping procedures, the performance of Pavlovian autoshaping CRs, and plasma corticosterone levels in male Long-Evans rats. In Experiment 1, rats in the CS-US paired group (n=30) were given 20 daily sessions of Pavlovian autoshaping training wherein the insertion of a retractable lever CS was followed by the response-independent presentation of the food US. Tail blood samples obtained after the 20th autoshaping session revealed higher plasma corticosterone levels in the CS-US paired group than in the CS-US random control group (n=10). In Experiment 2, rats (n=35) were assessed for basal plasma corticosterone levels 2 weeks prior to autoshaping training. Plasma samples obtained immediately following the first autoshaping session, and prior to the acquisition of lever-press autoshaping CR performance, revealed higher plasma corticosterone levels in the CS-US paired group (n=24) relative to basal levels. This effect was not observed in the CS-US random control group (n=11). Data suggest that corticosterone release is a physiological endocrine Pavlovian CR induced by lever CS-food US pairings during Pavlovian autoshaping procedures, rather than a by-product of autoshaping CR performance. Implications of the link between autoshaping procedures and corticosterone release are discussed.

  6. Post-column infusion study of the 'dosing vehicle effect' in the liquid chromatography/tandem mass spectrometric analysis of discovery pharmacokinetic samples.

    PubMed

    Shou, Wilson Z; Naidong, Weng

    2003-01-01

    It has become increasingly popular in drug development to conduct discovery pharmacokinetic (PK) studies in order to evaluate important PK parameters of new chemical entities (NCEs) early in the discovery process. In these studies, dosing vehicles are typically employed in high concentrations to dissolve the test compounds in dose formulations. This can pose significant problems for the liquid chromatography/tandem mass spectrometric (LC/MS/MS) analysis of incurred samples due to potential signal suppression of the analytes caused by the vehicles. In this paper, model test compounds in rat plasma were analyzed using a generic fast gradient LC/MS/MS method. Commonly used dosing vehicles, including poly(ethylene glycol) 400 (PEG 400), polysorbate 80 (Tween 80), hydroxypropyl beta-cyclodextrin, and N,N-dimethylacetamide, were fortified into rat plasma at 5 mg/mL before extraction. Their effects on the sample analysis results were evaluated by the method of post-column infusion. Results thus obtained indicated that polymeric vehicles such as PEG 400 and Tween 80 caused significant suppression (> 50%, compared with results obtained from plasma samples free from vehicles) to certain analytes, when minimum sample cleanup was used and the analytes happened to co-elute with the vehicles. Effective means to minimize this 'dosing vehicle effect' included better chromatographic separations, better sample cleanup, and alternative ionization methods. Finally, a real-world example is given to illustrate the suppression problem posed by high levels of PEG 400 in sample analysis, and to discuss steps taken in overcoming the problem. A simple but effective means of identifying a 'dosing vehicle effect' is also proposed. Copyright 2003 John Wiley & Sons, Ltd.

  7. Comparison of extraction methods for quantifying vitamin E from animal tissues.

    PubMed

    Xu, Zhimin

    2008-12-01

    Four extraction methods: (1) solvent (SOL), (2) ultrasound assisted solvent (UA), (3) saponification and solvent (SP), and (4) saponification and ultrasound assisted solvent (SP-UA), were used in sample preparation for quantifying vitamin E (tocopherols) in chicken liver and plasma samples. The extraction yields of SOL, UA, SP, and SP-UA methods obtained by adding delta-tocopherol as internal reference were 95%, 104%, 65%, and 62% for liver and 98%, 103%, 97%, and 94% for plasma, respectively. The methods with saponification significantly affected the stabilities of tocopherols in liver samples. The measured values of alpha- and gamma-tocopherols using the solvent only extraction (SOL) method were much lower than that using any of the other extraction methods. This indicated that less of the tocopherols in those samples were in a form that could be extracted directly by solvent. The measured value of alpha-tocopherol in the liver sample using the ultrasound assisted solvent (UA) method was 1.5-2.5 times of that obtained from the saponification and solvent (SP) method. The differences in measured values of tocopherols in the plasma samples by using the two methods were not significant. However, the measured value of the saponification and ultrasound assisted solvent (SP-UA) method was lower than either the saponification and solvent (SP) or the ultrasound assisted solvent (UA) method. Also, the reproducibility of the ultrasound assisted solvent (UA) method was greater than any of the saponification methods. Compared with the traditional saponification method, the ultrasound assisted solvent method could effectively extract tocopherols from sample matrix without any chemical degradation reactions, especially for complex animal tissue such as liver.

  8. Plasma clot formation and clot lysis to compare effects of different anticoagulation treatments on hemostasis in patients with atrial fibrillation.

    PubMed

    Königsbrügge, Oliver; Weigel, Günter; Quehenberger, Peter; Pabinger, Ingrid; Ay, Cihan

    2018-02-07

    The effect of direct oral anticoagulants (DOACs) on turbidimetric measurements of plasma clot formation and susceptibility to fibrinolysis may facilitate a comparison between different classes of anticoagulants in plasma samples. We obtained 424 citrate plasma samples from 226 atrial fibrillation patients on anticoagulation and 24 samples without anticoagulation serving as controls. As comparators, we measured the international normalized ratio (INR) for phenprocoumon samples (N = 166), anti-Xa for low molecular weight heparin (LMWH) samples (N = 42), and DOAC levels with mass spectrometry (dabigatran N = 40, rivaroxaban N = 110, apixaban N = 42). Plasma clot formation and lysis were recorded continuously on a photometer after addition of an activation mix (tissue factor 2 pmol/l and tissue plasminogen activator 333 ng/ml). We used linear regression and ANCOVA for correlation analysis. Clot formation lag phase was prolonged in the presence of anticoagulants in a concentration-dependent manner for DOACs (dabigatran Spearman r = 0.74; rivaroxaban r = 0.78; apixaban r = 0.72, all p < 0.0001), INR dependent for phenprocoumon (r = 0.59, p < 0.0001), anti-Xa level dependent in LMWH samples (r = 0.90, p < 0.0001). Maximum rate of clot formation and peak clot turbidity were reduced in the presence of anticoagulants, but correlated only moderately with the comparator measures of anticoagulation. The clot lysis time was inversely correlated with DOAC concentrations in the presence of recombinant thrombomodulin. A direct ex vivo comparison between the effects of different classes of anticoagulants is possible with turbidimetric measurement of plasma clot formation and lysis. Anticoagulation inhibited clot formation in a plasma concentration manner for DOACs, INR dependent for phenprocoumon, and anti-Xa dependent for LMWH. Susceptibility to fibrinolysis increased with increasing DOAC concentrations.

  9. Age-specific discrimination of blood plasma samples of healthy and ovarian cancer prone mice using laser-induced breakdown spectroscopy

    NASA Astrophysics Data System (ADS)

    Melikechi, Noureddine; Markushin, Yuri; Connolly, Denise C.; Lasue, Jeremie; Ewusi-Annan, Ebo; Makrogiannis, Sokratis

    2016-09-01

    Epithelial ovarian cancer (EOC) mortality rates are strongly correlated with the stage at which it is diagnosed. Detection of EOC prior to its dissemination from the site of origin is known to significantly improve the patient outcome. However, there are currently no effective methods for early detection of the most common and lethal subtype of EOC. We sought to determine whether laser-induced breakdown spectroscopy (LIBS) and classification techniques such as linear discriminant analysis (LDA) and random forest (RF) could classify and differentiate blood plasma specimens from transgenic mice with ovarian carcinoma and wild type control mice. Herein we report results using this approach to distinguish blood plasma samples obtained from serially bled (at 8, 12, and 16 weeks) tumor-bearing TgMISIIR-TAg transgenic and wild type cancer-free littermate control mice. We have calculated the age-specific accuracy of classification using 18,000 laser-induced breakdown spectra of the blood plasma samples from tumor-bearing mice and wild type controls. When the analysis is performed in the spectral range 250 nm to 680 nm using LDA, these are 76.7 (± 2.6)%, 71.2 (± 1.3)%, and 73.1 (± 1.4)%, for the 8, 12 and 16 weeks. When the RF classifier is used, we obtain values of 78.5 (± 2.3)%, 76.9 (± 2.1)% and 75.4 (± 2.0)% in the spectral range of 250 nm to 680 nm, and 81.0 (± 1.8)%, 80.4 (± 2.1)% and 79.6 (± 3.5)% in 220 nm to 850 nm. In addition, we report, the positive and negative predictive values of the classification of the two classes of blood plasma samples. The approach used in this study is rapid, requires only 5 μL of blood plasma, and is based on the use of unsupervised and widely accepted multivariate analysis algorithms. These findings suggest that LIBS and multivariate analysis may be a novel approach for detecting EOC.

  10. Plasma Levels of Nitrite and Nitrate in Early and Recent Classes of Fish

    PubMed Central

    Williams, Donna A; Flood, Mary H; Lewis, Debra A; Miller, Virginia M; Krause, William J

    2008-01-01

    The stable metabolite of nitric oxide in plasma is NOx, the sum of nitrite plus nitrate. Measures of plasma NOx may provide information about the nitric oxide tonus of the entire endothelium including capillary microvessels. Although data are available for mammalian species, plasma NOx measurements in early vertebrate species are scarce. The purpose of this study was to test the hypothesis that plasma NOx would be similar to the NOx in the water environment for fish in early classes (Agnatha and Chondrichthye) and would exceed water NOx levels in the known nitrite-sensitive fish (Osteichthye). Plasma samples were obtained from 18 species of adult fish (n = 167) and from their housing or natural water environment. NOx was measured by using chemiluminescence. Plasma NOx was detected in all species and ranged from 0.5 nmol/ml (skate) to 453.9 nmol/ml (shortnose gar). Average plasma NOx was significantly higher in sea lamprey than in Atlantic hagfish whereas that of little skate was 3-fold lower than in spiny dogfish shark. Plasma NOx differed significantly among early bony fish (paddlefish, pallid sturgeon, gar) yet was similar among modern bony fish, with the exception of rainbow trout. Plasma NOx reflected water NOx in only 2 species (hagfish and shark), and levels did not coincide with nitrite sensitivity. This study provides an expanded comparative view of plasma NOx levels across 3 groups of early fish. The data obtained suggest a nitric oxide system in early and modern fish. PMID:19004368

  11. Stable isotope dilution analysis of hydrologic samples by inductively coupled plasma mass spectrometry

    USGS Publications Warehouse

    Garbarino, John R.; Taylor, Howard E.

    1987-01-01

    Inductively coupled plasma mass spectrometry is employed in the determination of Ni, Cu, Sr, Cd, Ba, Ti, and Pb in nonsaline, natural water samples by stable isotope dilution analysis. Hydrologic samples were directly analyzed without any unusual pretreatment. Interference effects related to overlapping isobars, formation of metal oxide and multiply charged ions, and matrix composition were identified and suitable methods of correction evaluated. A comparability study snowed that single-element isotope dilution analysis was only marginally better than sequential multielement isotope dilution analysis. Accuracy and precision of the single-element method were determined on the basis of results obtained for standard reference materials. The instrumental technique was shown to be ideally suited for programs associated with certification of standard reference materials.

  12. Blood Substrate Collection and Handling Procedures under Pseudo-Field Conditions: Evaluation of Suitability for Inflammatory Biomarker Measurement

    PubMed Central

    Danese, Andrea; Shalev, Idan; Williams, Benjamin S.; Caspi, Avshalom

    2015-01-01

    Routine incorporation of blood-based biomarker measurements in population studies has been hampered by challenges in obtaining samples suitable for biomarker assessment outside of laboratory settings. Here, we assessed the suitability of venous blood left unprocessed for four, 24 or 48 hours post-collection at either room temperature or 4°C for quantification of two biomarkers, Interleukin-6 (IL-6) and C-Reactive Protein (CRP). Blood samples were collected in both K2EDTA tubes and a dedicated plasma-preservation tube, P100. Dried Blood Spot (DBS) samples from the same subjects were also collected in order to compare delayed-processing plasma performance against a popular alternative collection method. K2EDTA mean plasma concentrations of both IL-6 and CRP were not significantly different from concentrations in plasma processed immediately; this was observed for tubes stored up to 48 hours pre-processing at either temperature. Concentrations of IL-6 measured in P100 tubes showed significant time-dependent increases when stored at room temperature; otherwise, levels of IL-6 and CRP were similar to those processed immediately. Levels of CRP in DBS were correlated with plasma CRP levels, even when pre-processed blood was stored for up to 48 hours. These data indicate that plasma is suitable for IL-6 and CRP estimation under data-collection conditions that involve processing delays. PMID:26652682

  13. Evaluating the effect of sample type on American alligator ( Alligator mississippiensis) analyte values in a point-of-care blood analyser

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hamilton, Matthew T.; Finger, John W.; Winzeler, Megan E.

    The assessment of wildlife health has been enhanced by the ability of point-of-care (POC) blood analysers to provide biochemical analyses of non-domesticated animals in the field. However, environmental limitations (e.g. temperature, atmospheric humidity and rain) and lack of reference values may inhibit researchers from using such a device with certain wildlife species. Evaluating the use of alternative sample types, such as plasma, in a POC device may afford researchers the opportunity to delay sample analysis and the ability to use banked samples. In this study, we examined fresh whole blood, fresh plasma and frozen plasma (sample type) pH, partial pressuremore » of carbon dioxide (PCO 2), bicarbonate (HCO 3₋), total carbon dioxide (TCO 2), base excess (BE), partial pressure of oxygen (PO 2), oxygen saturation (sO 2) and lactate concentrations in 23 juvenile American alligators (Alligator mississippiensis) using an i-STAT CG4+ cartridge. Our results indicate that sample type had no effect on lactate concentration values (F 2,65 = 0.37, P = 0.963), suggesting that the i-STAT analyser can be used reliably to quantify lactate concentrations in fresh and frozen plasma samples. In contrast, the other seven blood parameters measured by the CG4+ cartridge were significantly affected by sample type. In conclusion, we were able to collect blood samples from all alligators within 2 min of capture to establish preliminary reference ranges for juvenile alligators based on values obtained using fresh whole blood.« less

  14. Evaluating the effect of sample type on American alligator (Alligator mississippiensis) analyte values in a point-of-care blood analyser

    PubMed Central

    Hamilton, Matthew T.; Finger, John W.; Winzeler, Megan E.; Tuberville, Tracey D.

    2016-01-01

    The assessment of wildlife health has been enhanced by the ability of point-of-care (POC) blood analysers to provide biochemical analyses of non-domesticated animals in the field. However, environmental limitations (e.g. temperature, atmospheric humidity and rain) and lack of reference values may inhibit researchers from using such a device with certain wildlife species. Evaluating the use of alternative sample types, such as plasma, in a POC device may afford researchers the opportunity to delay sample analysis and the ability to use banked samples. In this study, we examined fresh whole blood, fresh plasma and frozen plasma (sample type) pH, partial pressure of carbon dioxide (PCO2), bicarbonate (HCO3−), total carbon dioxide (TCO2), base excess (BE), partial pressure of oxygen (PO2), oxygen saturation (sO2) and lactate concentrations in 23 juvenile American alligators (Alligator mississippiensis) using an i-STAT CG4+ cartridge. Our results indicate that sample type had no effect on lactate concentration values (F2,65 = 0.37, P = 0.963), suggesting that the i-STAT analyser can be used reliably to quantify lactate concentrations in fresh and frozen plasma samples. In contrast, the other seven blood parameters measured by the CG4+ cartridge were significantly affected by sample type. Lastly, we were able to collect blood samples from all alligators within 2 min of capture to establish preliminary reference ranges for juvenile alligators based on values obtained using fresh whole blood. PMID:27382469

  15. Evaluating the effect of sample type on American alligator ( Alligator mississippiensis) analyte values in a point-of-care blood analyser

    DOE PAGES

    Hamilton, Matthew T.; Finger, John W.; Winzeler, Megan E.; ...

    2016-01-01

    The assessment of wildlife health has been enhanced by the ability of point-of-care (POC) blood analysers to provide biochemical analyses of non-domesticated animals in the field. However, environmental limitations (e.g. temperature, atmospheric humidity and rain) and lack of reference values may inhibit researchers from using such a device with certain wildlife species. Evaluating the use of alternative sample types, such as plasma, in a POC device may afford researchers the opportunity to delay sample analysis and the ability to use banked samples. In this study, we examined fresh whole blood, fresh plasma and frozen plasma (sample type) pH, partial pressuremore » of carbon dioxide (PCO 2), bicarbonate (HCO 3₋), total carbon dioxide (TCO 2), base excess (BE), partial pressure of oxygen (PO 2), oxygen saturation (sO 2) and lactate concentrations in 23 juvenile American alligators (Alligator mississippiensis) using an i-STAT CG4+ cartridge. Our results indicate that sample type had no effect on lactate concentration values (F 2,65 = 0.37, P = 0.963), suggesting that the i-STAT analyser can be used reliably to quantify lactate concentrations in fresh and frozen plasma samples. In contrast, the other seven blood parameters measured by the CG4+ cartridge were significantly affected by sample type. In conclusion, we were able to collect blood samples from all alligators within 2 min of capture to establish preliminary reference ranges for juvenile alligators based on values obtained using fresh whole blood.« less

  16. Cloud-point extraction is compatible with liquid chromatography coupled to electrospray ionization mass spectrometry for the determination of antazoline in human plasma.

    PubMed

    Giebułtowicz, Joanna; Kojro, Grzegorz; Piotrowski, Roman; Kułakowski, Piotr; Wroczyński, Piotr

    2016-09-05

    Cloud-point extraction (CPE) is attracting increasing interest in a number of analytical fields, including bioanalysis, as it provides a simple, safe and environmentally-friendly sample preparation technique. However, there are only few reports on the application of this extraction technique in liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI-MS/MS) analysis. In this study, CPE was used for the isolation of antazoline from human plasma. To date, only one method of antazoline isolation from plasma exists-liquid-liquid extraction (LLE). The aim of this study was to prove the compatibility of CPE and LC-ESI-MS/MS and the applicability of CPE to the determination of antazoline in spiked human plasma and clinical samples. Antazoline was isolated from human plasma using Triton X-114 as a surfactant. Xylometazoline was used as an internal standard. NaOH concentration, temperature and Triton X-114 concentration were optimized. The absolute matrix effect was carefully investigated. All validation experiments met international acceptance criteria and no significant relative matrix effect was observed. The compatibility of CPE and LC-ESI-MS/MS was confirmed using clinical plasma samples. The determination of antazoline concentration in human plasma in the range 10-2500ngmL(-1) by the CPE method led to results which are equivalent to those obtained by the widely used liquid-liquid extraction method. Copyright © 2016 Elsevier B.V. All rights reserved.

  17. MRM validation of targeted nonglycosylated peptides from N-glycoprotein biomarkers using direct trypsin digestion of undepleted human plasma.

    PubMed

    Lee, Ju Yeon; Kim, Jin Young; Cheon, Mi Hee; Park, Gun Wook; Ahn, Yeong Hee; Moon, Myeong Hee; Yoo, Jong Shin

    2014-02-26

    A rapid, simple, and reproducible MRM-based validation method for serological glycoprotein biomarkers in clinical use was developed by targeting the nonglycosylated tryptic peptides adjacent to N-glycosylation sites. Since changes in protein glycosylation are known to be associated with a variety of diseases, glycoproteins have been major targets in biomarker discovery. We previously found that nonglycosylated tryptic peptides adjacent to N-glycosylation sites differed in concentration between normal and hepatocellular carcinoma (HCC) plasma due to differences in steric hindrance of the glycan moiety in N-glycoproteins to tryptic digestion (Lee et al., 2011). To increase the feasibility and applicability of clinical validation of biomarker candidates (nonglycosylated tryptic peptides), we developed a method to effectively monitor nonglycosylated tryptic peptides from a large number of plasma samples and to reduce the total analysis time with maximizing the effect of steric hindrance by the glycans during digestion of glycoproteins. The AUC values of targeted nonglycosylated tryptic peptides were excellent (0.955 for GQYCYELDEK, 0.880 for FEDGVLDPDYPR and 0.907 for TEDTIFLR), indicating that these could be effective biomarkers for hepatocellular carcinoma. This method provides the necessary throughput required to validate glycoprotein biomarkers, as well as quantitative accuracy for human plasma analysis, and should be amenable to clinical use. Difficulties in verifying and validating putative protein biomarkers are often caused by complex sample preparation procedures required to determine their concentrations in a large number of plasma samples. To solve the difficulties, we developed MRM-based protein biomarker assays that greatly reduce complex, time-consuming, and less reproducible sample pretreatment steps in plasma for clinical implementation. First, we used undepleted human plasma samples without any enrichment procedures. Using nanoLC/MS/MS, we targeted nonglycosylated tryptic peptides adjacent to N-linked glycosylation sites in N-linked glycoprotein biomarkers, which could be detected in human plasma samples without depleting highly abundant proteins. Second, human plasma proteins were digested with trypsin without reduction and alkylation procedures to minimize sample preparation. Third, trypsin digestion times were shortened so as to obtain reproducible results with maximization of the steric hindrance effect of the glycans during enzyme digestion. Finally, this rapid and simple sample preparation method was applied to validate targeted nonglycosylated tryptic peptides as liver cancer biomarker candidates for diagnosis in 40 normal and 41 hepatocellular carcinoma (HCC) human plasma samples. This strategy provided the necessary throughput required to monitor protein biomarkers, as well as quantitative accuracy in human plasma analysis. From biomarker discovery to clinical implementation, our method will provide a biomarker study platform that is suitable for clinical deployment, and can be applied to high-throughput approaches. Copyright © 2014 Elsevier B.V. All rights reserved.

  18. Quantitative Method for Analysis of Hydrocodone, Hydromorphone and Norhydrocodone in Human Plasma by Liquid Chromatography-tandem Mass Spectrometry

    DTIC Science & Technology

    2013-03-01

    ratio ranges obtained for the six standards. Twelve samples were analyzed to demonstrate the efficiency of the extraction procedure. Drug and internal...frozen (−70 ◦C). Refrigerated samples were tested after 2 months of storage ; frozen samples were tested for up to 1 year from stor- age date. The...freeze–thaw stability was evaluated by analyzing three subject samples with known drug concentrations and two quality control samples at concentrations

  19. Million Degree Plasmas in Extreme Ultraviolet (EUV) Astrophysics. White Paper in Response to Astro2010 Science Call

    DTIC Science & Technology

    2010-01-01

    photometry , timing measurements of suitable cadence, and advanced theory are the keys to understanding the physics of million degree plasmas in...Disentangling these components requires time - and phase- resolved spectroscopic observations of a sample that spans a range of mass accretion rates...many narrow lines, or a continuum with strong, broad absorption features. Key Objective: Obtaining time - and phase- resolved high-resolution EUV

  20. Development and validation of a new method to simultaneously quantify triazoles in plasma spotted on dry sample spot devices and analysed by HPLC-MS.

    PubMed

    Baietto, Lorena; D'Avolio, Antonio; Marra, Cristina; Simiele, Marco; Cusato, Jessica; Pace, Simone; Ariaudo, Alessandra; De Rosa, Francesco Giuseppe; Di Perri, Giovanni

    2012-11-01

    Therapeutic drug monitoring (TDM) of triazoles is widely used in clinical practice to optimize therapy. TDM is limited by technical problems and cost considerations, such as sample storage and dry-ice shipping. We aimed to develop and validate a new method to analyse itraconazole, posaconazole and voriconazole in plasma spotted on dry sample spot devices (DSSDs) and to quantify them by an HPLC system. Extraction from DSSDs was done using n-hexane/ethyl acetate and ammonia solution. Samples were analysed using HPLC with mass spectrometry (HPLC-MS). Accuracy and precision were assayed by inter- and intra-day validation. The stability of triazoles in plasma spotted on DSSDs was investigated at room temperature for 1 month. The method was compared with a validated standard HPLC method for quantification of triazoles in human plasma. Mean inter- and intra-day accuracy and precision were <15% for all compounds. Triazoles were stable for 2 weeks at room temperature. The method was linear (r(2) > 0.999) in the range 0.031-8 mg/L for itraconazole and posaconazole, and 0.058-15 mg/L for voriconazole. High sensitivity was observed; limits of detection were 0.008, 0.004 and 0.007 mg/L for itraconazole, posaconazole and voriconazole, respectively. A high degree of correlation (r(2) > 0.94) was obtained between the DSSD method and the standard method of analysis. The method that we developed and validated to quantify triazoles in human plasma spotted on DSSDs is accurate and precise. It overcomes problems related to plasma sample storage and shipment, allowing TDM to be performed in a cheaper and safer manner.

  1. Effects of female bovine plasma collected at different days of the estrous cycle on epididymal spermatozoa motility.

    PubMed

    Nait Mouloud, M; Ouennoughi, F; Yaiche, L; Kaidi, R; Iguer-Ouada, M

    2017-03-15

    The aim of this study was to assess the effects of female bovine plasma collected at different days of the reproductive cycle on epididymal spermatozoa motility and to test hypothesis that the subpopulations pattern of motile spermatozoa is affected by this treatment. Blood plasma samples were collected from five Holstein Friesian cows at different stages of the estrous cycle (days 0, 5, 10, 12 and 18), one pregnant cow and one adult bull and were diluted 1:9 (V/V) with normal saline. Female charcoal-treated plasma, Bull plasma and saline were used as controls. Semen samples were obtained from cauda epididymidis through retrograde flushing and diluted in saline to approximately 60 × 106 sperm/ml. The extended semen was diluted 1:2 (V/V) with tested media and motility was evaluated at 15 min and then every hour for 6 h using a computer-assisted semen analysis. Multivariate clustering procedure was applied to identify and quantify specific subpopulations within the semen samples. The statistical analysis clustered all the motile spermatozoa into three separate subpopulations with defined patterns of movement: Subpopulation 1 poorly motile and non-progressive spermatozoa (39.3%), subpopulation 2 including the fastest and the most vigorous spermatozoa (46.4%) and subpopulation 3 represented by slow, non-vigorous but linear spermatozoa (14.3%). Initially, sperm samples supplemented with female, male or female charcoal-treated plasma stimulated equally total motility and spermatozoa belonging to subpopulation 2 regardless of the estrous cycle stage. After 1-h incubation, the motility of these both categories of spermatozoa (total motile and those assigned to subpopulation 2) is enhanced and maintained more in day 12, 18 and pregnant cow plasma than in female plasma from earlier stage of the estrous cycle (day 0, 5 and 10), male plasma and female-charcoal treated plasma. In conclusion, the overall results showed that female plasma stimulated significantly sperm motility, especially at the late stage of the estrous cycle. Additionally, to the diverse compounds contained in blood plasma, progesterone may play a key role in such motility activation. Copyright © 2016 Elsevier Inc. All rights reserved.

  2. Insight into hydrogenation of graphene: Effect of hydrogen plasma chemistry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Felten, A.; Nittler, L.; Pireaux, J.-J.

    2014-11-03

    Plasma hydrogenation of graphene has been proposed as a tool to modify the properties of graphene. However, hydrogen plasma is a complex system and controlled hydrogenation of graphene suffers from a lack of understanding of the plasma chemistry. Here, we correlate the modifications induced on monolayer graphene studied by Raman spectroscopy with the hydrogen ions energy distributions obtained by mass spectrometry. We measure the energy distribution of H{sup +}, H{sub 2}{sup +}, and H{sub 3}{sup +} ions for different plasma conditions showing that their energy strongly depends on the sample position, pressure, and plasma power and can reach values asmore » high as 45 eV. Based on these measurements, we speculate that under specific plasma parameters, protons should possess enough energy to penetrate the graphene sheet. Therefore, a graphene membrane could become, under certain conditions, transparent to both protons and electrons.« less

  3. Increased germination and growth rates of pea and Zucchini seed by FSG plasma

    NASA Astrophysics Data System (ADS)

    Khatami, Shohreh; Ahmadinia, Arash

    2018-04-01

    Recently, cold atmospheric plasma (CAP) with the unique bio-disinfection features is used in various fields of industry, medicine, and agriculture. The main objectives of this work were to design FSG plasma (a semi-automatic device) and investigate the effect of the cold plasma in the enhancement of the Pea and Zucchini seed germination. Plasma irradiation time was studied to obtain a proper condition for the germination enhancement of seeds. The growth rate was calculated by measuring length of root and stem and dry weight of plants treated by plasma. To investigate drought resistance of plants, all treated and untreated samples were kept in darkness without water for 48 h. From the experimental results, it could be confirmed both drought resistance and germination of seedlings increased after plasma was applied to seeds at 30 s, while seeds treated whiten 60 s showed a decrease in both germination rate and seedling growth.

  4. Validation of a simple HPLC-UV method for rifampicin determination in plasma: Application to the study of rifampicin arteriovenous concentration gradient.

    PubMed

    Goutal, Sébastien; Auvity, Sylvain; Legrand, Tiphaine; Hauquier, Fanny; Cisternino, Salvatore; Chapy, Hélène; Saba, Wadad; Tournier, Nicolas

    2016-05-10

    In clinical practice, rifampicin exposure is estimated from its concentration in venous blood samples. In this study, we hypothesized that differences in rifampicin concentration may exist between arterial and venous plasma. An HPLC-UV method for determining rifampicin concentration in plasma using rifapentine as an internal standard was validated. The method, which requires a simple protein precipitation procedure as sample preparation, was performed to compare venous and arterial plasma kinetics after a single therapeutic dose of rifampicin (8.6 mg/kg i.v, infused over 30 min) in baboons (n=3). The method was linear from 0.1 to 40 μg mL(-1) and all validation parameters fulfilled the international requirements. In baboons, rifampicin concentration in arterial plasma was higher than in venous plasma. Arterial Cmax was 2.1±0.2 fold higher than venous Cmax. The area under the curve (AUC) from 0 to 120 min was ∼80% higher in arterial plasma, indicating a significant arteriovenous concentration gradient in early rifampicin pharmacokinetics. Arterial and venous plasma concentrations obtained 6h after rifampicin injection were not different. An important arteriovenous equilibration delay for rifampicin pharmacokinetics is reported. Determination in venous plasma concentrations may considerably underestimate rifampicin exposure to organs during the distribution phase. Copyright © 2016 Elsevier B.V. All rights reserved.

  5. Dependence of nanomechanical modification of polymers on plasma-induced cross-linking

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tajima, S.; Komvopoulos, K.

    2007-01-01

    The nanomechanical properties of low-density polyethylene (LDPE) modified by inductively coupled, radio-frequency Ar plasma were investigated by surface force microscopy. The polymer surface was modified under plasma conditions of different ion energy fluences and radiation intensities obtained by varying the sample distance from the plasma power source. Nanoindentation results of the surface stiffness versus maximum penetration depth did not reveal discernible differences between untreated and plasma-treated LDPE, presumably due to the small thickness of the modified surface layer that resulted in a substrate effect. On the contrary, nanoscratching experiments demonstrated a significant increase in the surface shear resistance of plasma-modifiedmore » LDPE due to chain cross-linking. These experiments revealed an enhancement of cross-linking with increasing ion energy fluence and radiation intensity, and a tip size effect on the friction force and dominant friction mechanisms (adhesion, plowing, and microcutting). In addition, LDPE samples with a LiF crystal shield were exposed to identical plasma conditions to determine the role of vacuum ultraviolet (VUV) and ultraviolet (UV) radiation in the cross-linking process. The cross-linked layer of plasma-treated LDPE exhibited much higher shear strength than that of VUV/UV-treated LDPE. Plasma-induced surface modification of the nanomechanical properties of LDPE is interpreted in the context of molecular models of the untreated and cross-linked polymer surfaces derived from experimental findings.« less

  6. Fatty acid methyl esters are detectable in the plasma and their presence correlates with liver dysfunction.

    PubMed

    Aleryani, Samir Lutf; Cluette-Brown, Joanne E; Khan, Zia A; Hasaba, Hasan; Lopez de Heredia, Luis; Laposata, Michael

    2005-09-01

    Methanol is a component of certain alcoholic beverages and is also an endogenously formed product. On this basis, we have proposed that methanol may promote synthesis of fatty acid methyl esters (FAMEs) in the same way that ethanol promotes fatty acid ethyl ester (FAEE) synthesis. We tested the hypothesis that FAMEs appear in the blood after ethanol intake. Patient plasma samples obtained from our laboratory (n=78) were grouped according to blood ethanol concentrations (intoxicated, blood ethanol >800 mg/l) and non-intoxicated. These samples were further subdivided into groups based on whether the patient had normal or abnormal liver function tests (abnormal, defined as > or =1 abnormality of plasma alanine and aspartate aminotransferase, albumin, total bilirubin, and alkaline phosphatase). A separate set of plasma samples were also divided into normal and abnormal groups based on pancreatic function tests (amylase and lipase). There were no patients with detectable ethanol in this group. Patients with abnormalities in pancreatic function tests were included upon recognition of endogenously produced FAMEs by patients with liver function test abnormalities. FAMEs were extracted from plasma and individual species of FAMEs quantified by gas chromatography-mass spectrometry (GC/MS). Increased concentrations of FAME were found in patient samples with evidence of liver dysfunction, regardless of whether or not they were intoxicated (n=21, p=0.01). No significant differences in plasma FAME concentrations were found between patients with normal (n=15) versus abnormal pancreatic function tests (n=22, p=0.72). The presence of FAMEs in human plasma may be related to the existence of liver disease, and not to blood ethanol concentrations or pancreatic dysfunction. The metabolic pathways associated with FAME production in patients with impaired liver function remain to be identified.

  7. Detection of EGFR Variants in Plasma: A Multilaboratory Comparison of the cobas EGFR Mutation Test v2 in Europe.

    PubMed

    Keppens, Cleo; Palma, John F; Das, Partha M; Scudder, Sidney; Wen, Wei; Normanno, Nicola; Van Krieken, J Han; Sacco, Alessandra; Fenizia, Francesca; de Castro, David Gonzalez; Hönigschnabl, Selma; Kern, Izidor; Lopez-Rios, Fernando; Lozano, Maria D; Marchetti, Antonio; Halfon, Philippe; Schuuring, Ed; Setinek, Ulrike; Sorensen, Boe; Taniere, Phillipe; Tiemann, Markus; Vosmikova, Hana; Dequeker, Elisabeth M C

    2018-04-25

    Molecular testing of EGFR is required to predict the response likelihood to targeted therapy in non-small-cell lung cancer. Analysis of circulating tumor DNA in plasma may complement limitations of tumor tissue. This study evaluated the interlaboratory performance and reproducibility of the cobas EGFR Mutation Test v2 to detect EGFR variants in plasma. Fourteen laboratories received two identical panels of 27 single-blinded plasma samples. Samples were wild-type or spiked with plasmid DNA to contain seven common EGFR variants at six predefined concentrations from 50 to 5000 copies per mL. The circulating tumor DNA was extracted by the cobas cfDNA Sample Preparation kit, followed by duplicate analysis with the EGFRv2 kit (Roche Molecular Systems, Pleasanton, CA). Lowest sensitivities were obtained for the c.2156G>C p.(Gly719Ala) and c.2573T>G p.(Leu858Arg) variants for the lowest target copies. For all other variants, sensitivities varied between 96.3% and 100.0%. Specificities were all 98.8% to 100.0%. Coefficients of variation indicated good intra and interlaboratory repeatability and reproducibility, but increased for decreasing concentrations. Prediction models revealed a significant correlation for all variants between the pre-defined copy number and the observed semiquantitative index values which reflects the samples' plasma mutation load. This study demonstrates an overall robust performance of the EGFRv2 kit in plasma. Prediction models may be applied to estimate the plasma mutation load for diagnostic or research purposes. Copyright © 2018 American Society for Investigative Pathology and the Association for Molecular Pathology. Published by Elsevier Inc. All rights reserved.

  8. Structural and magnetic properties of spark plasma sintered Co-Mg-Zn substituted Ba-Sr hexagonal ferrite magnets

    NASA Astrophysics Data System (ADS)

    Harikrishnan, V.; Vizhi, R. Ezhil; Rajan Babu, D.; Saravanan, P.

    2018-02-01

    The effect of conventional and spark plasma sintering processes on the structural and magnetic properties of Ba0.5Sr0.5Fe12-2xCox(MgZn)x/2O19 (x = 0.2, 0.4 and 0.6) was investigated in this study. XRD patterns of both conventionally sintered (CS) and spark plasma sintered (SPS) samples with x = 0.2 and 0.4 showed the crystallization of Ba0.5Sr0.5Fe12O19-phase with space group of P63/mmc. However, in the case of SPS sample with x = 0.4, a secondary peak of α-Fe2O3 was observed. SEM analysis on the SPS samples revealed dense morphology with low porosity; while the CS samples showed the presence of aggregated particles with spherical shapes. Maximum values of saturation magnetization, MS (58 emu/g) and coercivity, HC (3.5 kOe) were obtained for the CS samples with x = 0.4; while their SPS counterparts revealed increased MS (65 emu/g) and HC (3.9 kOe) values. The observed magnetization reversal behaviour for both sintering conditions were not smooth in the case of x = 0.2, which indicated the existence of two-phase behavior. The temperature dependent magnetization studies for x = 0.2 and 0.4 were performed in order to analyze the variation in Curie temperature against Co-Mg-Zn substitution and the obtained results are discussed on the basis of crystallization of hexaferrite-phase.

  9. Characterization of injected aluminum oxide nanoparticle clouds in an rf discharge

    NASA Astrophysics Data System (ADS)

    Krüger, Harald; Killer, Carsten; Schütt, Stefan; Melzer, André

    2018-02-01

    An experimental setup to deagglomerate and insert nanoparticles into a radio frequency discharge has been developed to confine defined aluminum oxide nanoparticles in a dusty plasma. For the confined particle clouds we have measured the spatially resolved in situ size and density distributions. Implementing the whole plasma chamber into the sample volume of an FTIR spectrometer the infrared spectrum of the confined aluminum oxide nanoparticles has been obtained. We have investigated the dependency of the absorbance of the nanoparticles in terms of plasma power, pressure and cloud shape. The particles’ infrared phonon resonance has been identified.

  10. Fluorescence spectra of blood plasma treated with ultraviolet irradiation in vivo

    NASA Astrophysics Data System (ADS)

    Zalesskaya, G. A.; Maslova, T. O.

    2010-09-01

    We have studied the fluorescence spectra of blood plasma from patients with acute coronary syndrome, and also the effect of therapeutic doses of in vivo ultraviolet blood irradiation (UBI) on the spectra. We have established that the maxima in the fluorescence spectra of the original plasma samples, obtained from unirradiated blood, are located in the wavelength interval 330-340 nm, characteristic for the fluorescence of tryptophan residues. In extracorporeal UBI ( λ = 254 nm), we observed changes in the shape and also both a blue and a red shift in the maxima of the fluorescence spectra, differing in magnitude for blood plasma samples from different patients in the test group. We show that UBI-initiated changes in the fluorescence spectra of the plasma depend on the original pathological disturbances of metabolite levels, and also on the change in the oxygen-transport function of the blood and the acid-base balance, affecting the oxidative stability of the plasma. We have concluded that UV irradiation, activating buffer systems in the blood, has an effect on the universal and specific interactions of the tryptophan residue with the amino acid residues and water surrounding it.

  11. Bioequivalence and Pharmacokinetic Evaluation Study of Acetaminophen vs. Acetaminophen Plus Caffeine Tablets in Healthy Mexican Volunteers.

    PubMed

    Guzmán, Nora Angélica Núñez; Molina, Daniel Ruiz; Núñez, Benigno Figueroa; Soto-Sosa, Juan Carlos; Abarca, Jorge Eduardo Herrera

    2016-12-01

    The aim of this clinical trial was to establish the bioequivalence of two tablets containing acetaminophen 650 mg (reference) and acetaminophen 650 mg plus caffeine 65 mg (test), administered orally, in fasting conditions in healthy Mexican volunteers. Blood samples were taken from 21 male and five female individuals, during a 24-h period, to characterize the pharmacokinetic profile of acetaminophen. Plasma samples were quantified by ultra-performance liquid chromatography, tandem mass spectrometry. Pharmacokinetic metrics (maximum plasma concentration, area under the curve from time zero to the last sampling time, and area under the curve from time zero to infinity) were used to determine the 90 % confidence interval of the test/reference coefficient. The geometric mean values for maximum plasma concentration obtained for the reference and test products were 9.46 ± 34.21 and 9.72 ± 32.38 µg/mL, respectively, whereas for the area under the curve from time zero to the last sampling time the values obtained were 34.93 ± 32.58 and 35.89 ± 31.03 µg h/mL for the reference and test formulations, respectively. The 90 % confidence intervals were within the acceptance range (80-125 %). The test product was bioequivalent to the reference product. A faster absorption was seen in the test formulation in the Mexican population.

  12. Direct detection of fibrinogen in human plasma using electric-double-layer gated AlGaN/GaN high electron mobility transistors

    NASA Astrophysics Data System (ADS)

    Regmi, Abiral; Sarangadharan, Indu; Chen, Yen-Wen; Hsu, Chen-Pin; Lee, Geng-Yen; Chyi, Jen-Inn; Shiesh, Shu-Chu; Lee, Gwo-Bin; Wang, Yu-Lin

    2017-08-01

    Fibrinogen found in blood plasma is an important protein biomarker for potentially fatal diseases such as cardiovascular diseases. This study focuses on the development of an assay to detect plasmatic fibrinogen using electrical double layer gated AlGaN/GaN high electron mobility transistor biosensors without complex sample pre-treatment methods used in the traditional assays. The test results in buffer solution and clinical plasma samples show high sensitivity, specificity, and dynamic range. The sensor exhibits an ultra-low detection limit of 0.5 g/l and a detection range of 0.5-4.5 g/l in 1× PBS with 1% BSA. The concentration dependent sensor signal in human serum samples demonstrates the specificity to fibrinogen in a highly dense matrix of background proteins. The sensor does not require complicated automation, and quantitative results are obtained in 5 min with <5 μl sample volume. This sensing technique is ideal for speedy blood based diagnostics such as POC (point of care) tests, homecare tests, or personalized healthcare.

  13. Vitamins D and A can be successfully measured by LC-MS/MS in cord blood diluted plasma.

    PubMed

    Albarhani, Ali A; Collier, Fiona; Greaves, Ronda F; Ponsonby, Anne-Louise; Allen, Katrina J; Vuillermin, Peter J; Roche, Peter; Clarke, Michael W

    2015-11-01

    In widely used protocols for the collection and isolation of cord blood mononuclear cells, investigators are left with substantial volumes of diluted plasma which could be used for other measurements. The aim of this study was to ascertain the validity of umbilical cord blood (UCB) diluted plasma samples for vitamin D, A and E analysis compared to UCB serum samples. Twenty UCB matched samples of diluted plasma and serum were collected. The samples were analysed by two liquid chromatography-tandem mass spectrometry (LC-MS/MS) methods on two separate occasions. The results of 25(OH)D3 obtained by the two laboratories demonstrated close agreement with a mean difference of 0.14nmol/L [95% confidence interval (95% CI), -6.8 to 7.1]. Both methods demonstrate close agreement for 25(OH)D3 in UCB serum versus diluted UCB plasma; mean difference 2.2nmol/L [95% CI, -9.5 to 13.9] and 4.1nmol/L [95% CI, -14.5 to 6.1] for the results from Lab A and Lab B, respectively. Vitamin A was quantified by Lab A in UCB serum and diluted UCB plasma; mean difference 0.07μmol/L [95% CI, -0.41 to 0.28]. Results of 25(OH)D3 epimer and vitamin E in the diluted UCB plasma were below the limit of quantification, and could not be compared with UCB serum. Diluted UCB plasma can be used for the quantification of retinol and 25(OH)D3 by LC-MS/MS. By contrast, quantification of 25(OH)D3 epimer and vitamin E in diluted UCB plasma is not supported by this study due to limitations in analytical sensitivity. Copyright © 2015 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  14. Disposition of enrofloxacin and its metabolite ciprofloxacin after intramuscular injection in juvenile Burmese pythons (Python molurus bivittatus).

    PubMed

    Young, L A; Schumacher, J; Papich, M G; Jacobson, E R

    1997-03-01

    Eleven juvenile Burmese pythons (Python molurus bivittatus) weighing 0.75-1.75 kg were randomly divided into two groups. Blood samples were obtained through surgically placed anterior carotid artery cannulas. Six pythons received a single i.m. injection of enrofloxacin at 5 mg/kg. Blood samples were obtained at 0.5, 1, 3, 6, 12, 24, 48, 72, and 96 hr postinjection. A mean (+/- SD) maximal plasma concentration of 1.66 (+/- 0.42) micrograms/ml was measured at 5.75 hr postinjection. The harmonic mean half-life was calculated to be 6.37 hr. The second group of five snakes received enrofloxacin at 5 mg/kg i.m. s.i.d. for 5 days. Blood was collected immediately before each injection and at 6 hr after each injection. Over the 5-day period, there was a stepwise increase in mean trough plasma concentrations of enrofloxacin. Clinically effective peak plasma enrofloxacin concentrations were attained after the first injection but did not significantly increase during the sampling period. Pharmacokinetic data were assessed against minimum inhibitory concentrations of enrofloxacin for Pseudomonas ssp. isolates in snakes obtained from historical data at the Veterinary Medical Teaching Hospital, University of Florida. Enrofloxacin should be administered at 10 mg/kg i.m. every 48 hr when treating Pseudomonas ssp. infections in juvenile Burmese pythons. Treatment of infections of more enrofloxacin-sensitive gram-negative bacteria could be achieved with the administration of an initial i.m. dose of 10 mg/kg followed by 5 mg/kg every 48 hr.

  15. Accuracy of the HumaSensplus point-of-care uric acid meter using capillary blood obtained by fingertip puncture.

    PubMed

    Fabre, Stéphanie; Clerson, Pierre; Launay, Jean-Marie; Gautier, Jean-François; Vidal-Trecan, Tiphaine; Riveline, Jean-Pierre; Platt, Adam; Abrahamsson, Anna; Miner, Jeffrey N; Hughes, Glen; Richette, Pascal; Bardin, Thomas

    2018-05-02

    The uric acid (UA) level in patients with gout is a key factor in disease management and is typically measured in the laboratory using plasma samples obtained after venous puncture. This study aimed to assess the reliability of immediate UA measurement with capillary blood samples obtained by fingertip puncture with the HumaSens plus point-of-care meter. UA levels were measured using both the HumaSens plus meter in the clinic and the routine plasma UA method in the biochemistry laboratory of 238 consenting diabetic patients. HumaSens plus capillary and routine plasma UA measurements were compared by linear regression, Bland-Altman plots, intraclass correlation coefficient (ICC), and Lin's concordance coefficient. Values outside the dynamic range of the meter, low (LO) or high (HI), were analyzed separately. The best capillary UA thresholds for detecting hyperuricemia were determined by receiver operating characteristic (ROC) curves. The impact of potential confounding factors (demographic and biological parameters/treatments) was assessed. Capillary and routine plasma UA levels were compared to reference plasma UA measurements by liquid chromatography-mass spectrometry (LC-MS) for a subgroup of 67 patients. In total, 205 patients had capillary and routine plasma UA measurements available. ICC was 0.90 (95% confidence interval (CI) 0.87-0.92), Lin's coefficient was 0.91 (0.88-0.93), and the Bland-Altman plot showed good agreement over all tested values. Overall, 17 patients showed values outside the dynamic range. LO values were concordant with plasma values, but HI values were considered uninterpretable. Capillary UA thresholds of 299 and 340 μmol/l gave the best results for detecting hyperuricemia (corresponding to routine plasma UA thresholds of 300 and 360 μmol/l, respectively). No significant confounding factor was found among those tested, except for hematocrit; however, this had a negligible influence on the assay reliability. When capillary and routine plasma results were discordant, comparison with LC-MS measurements showed that plasma measurements had better concordance: capillary UA, ICC 0.84 (95% CI 0.75-0.90), Lin's coefficient 0.84 (0.77-0.91); plasma UA, ICC 0.96 (0.94-0.98), Lin's coefficient 0.96 (0.94-0.98). UA measurements with the HumaSens plus meter were reasonably comparable with those of the laboratory assay. The meter is easy to use and may be useful in the clinic and in epidemiologic studies.

  16. Three-phase molecularly imprinted sol-gel based hollow fiber liquid-phase microextraction combined with liquid chromatography-tandem mass spectrometry for enrichment and selective determination of a tentative lung cancer biomarker.

    PubMed

    Moein, Mohammad Mahdi; Javanbakht, Mehran; Karimi, Mohammad; Akbari-Adergani, Behrouz; Abdel-Rehim, Mohamed

    2015-07-15

    In the present study, the modification of a polysulfone hollow fiber membrane with in situ molecularly imprinted sol-gel process (as a novel and one-step method) was prepared and investigated. 3-(propylmethacrylate)trimethoxysilane (3PMTMOS) as an inorganic precursor was used for preparation of molecularly imprinted sol-gel. The modified molecularly imprinted sol-gel hollow fiber membrane (MSHM) was used for the liquid-phase microextraction (LPME) of hippuric acid (HA) in human plasma and urine samples. MSHM as a selective, robust, and durable tool was used for at least 50 extractions without significant decrease in the extraction efficiency. The non-molecularly imprinted sol-gel hollow fiber membrane (NSHM) as blank hollow fiber membrane was prepared by the same process, only without HA. To achieve the best condition, influential parameters on the extraction efficiency were thoroughly investigated. The capability of this robust, green, and simple method for extraction of HA was successfully accomplished with LC/MS/MS. The limits of detection (LOD) and quantification (LOQ) in human plasma and urine samples were 0.3 and 1.0nmolL(-1), respectively. The standard calibration curves were obtained within the concentration range 1-2000nmolL(-1) for HA in human plasma and urine. The coefficients of determination (r(2)) were ≥0.998. The obtained data exhibited recoveries were higher than 89% for the extraction of HA in human plasma and urine samples. Copyright © 2015 Elsevier B.V. All rights reserved.

  17. Glycosaminoglycan and transforming growth factor beta1 changes in human plasma and urine during the menstrual cycle, in vitro fertilization treatment, and pregnancy.

    PubMed

    De Muro, Pierina; Capobianco, Giampiero; Formato, Marilena; Lepedda, Antonio Junior; Cherchi, Gian Mario; Gordini, Laila; Dessole, Salvatore

    2009-07-01

    To evaluate transforming growth factor beta1 (TGF-beta1) and glycosaminoglycans (GAG) changes in human plasma and urine during the menstrual cycle, IVF-ET, and pregnancy. Prospective clinical study. University hospital. Thirteen women with apparently normal menstrual cycle (group 1); 18 women undergoing IVF-ET (group 2); and 14 low-risk pregnant women (group 3). We assayed plasma and urine concentrations of TGF-beta1, urine content, and distribution of GAG. Blood and urine samples were collected during days 2 to 3, 12 to 13, and 23 to 24 in group 1; in group 2, samples were obtained at menstrual phase, oocyte pick-up day, and 15 days after ET; in group 3, samples were obtained during gestational weeks 10-12, 22-24, and 30-32 and 1 month after delivery. Changes in TGF-beta1 and GAG content. The mean value of total urinary trypsin inhibitor/chondroitin sulfate (UTI/CS) showed a distinct peak at day 12 of the menstrual cycle in the fertile women in whom we monitored the ovulatory period. In the IVF-ET group, GAG distribution and TGF-beta1 levels showed significant differences during the cycle. We observed increased levels of plasma TGF-beta1 15 days after ET. A significant increase of total UTI/CS value with increasing gestation was detected. Transforming growth factor beta1 and GAG levels could represent an additional tool to monitor reproductive events and could be useful, noninvasive markers of ovulation and ongoing pregnancy.

  18. MicroRNA-6826 and -6875 in plasma are valuable non‑invasive biomarkers that predict the efficacy of vaccine treatment against metastatic colorectal cancer.

    PubMed

    Kijima, Taiki; Hazama, Shoichi; Tsunedomi, Ryouichi; Tanaka, Hironori; Takenouchi, Hiroko; Kanekiyo, Shinsuke; Inoue, Yuka; Nakashima, Masao; Iida, Michihisa; Sakamoto, Kazuhiko; Suzuki, Nobuaki; Takeda, Shigeru; Ueno, Tomio; Yamamoto, Shigeru; Yoshino, Shigefumi; Okuno, Kiyotaka; Nagano, Hiroaki

    2017-01-01

    Various vaccine treatments against metastatic colorectal cancer have been developed and applied. However, to improve the efficacy of immunotherapy, biomarkers that can predict the effects are needed. It has been reported that various microRNAs (miRNAs) in peripheral blood may be useful as non-invasive biomarkers. In this study, miRNAs influencing the efficacy of vaccine treatment were screened for in a microarray analysis of 13 plasma samples that were obtained from patients prior to vaccine treatment. To validate the screening results, real-time RT-PCR was performed using 93 plasma samples obtained from patients prior to vaccine treatment. Four candidate miRNAs were selected according to the results of the comprehensive analysis of miRNA expression, which were ranked using the Fisher criterion and the absolute value of the log2 ratio in the screening analysis. The validation analysis showed that in the HLA-A*2402‑matched patient group (vaccine-treated group), patients with a high expression of plasma miR-6826 had a poorer prognosis than those with a low expression (P=0.048). In contrast, in the HLA-A*2402-unmatched patient group (control group), there was no difference between the patients with high or low plasma miR-6826 expression (P=0.168). Similar results were obtained in the analysis of miR-6875 (P=0.029 and P=0.754, respectively). Moreover, multivariate analysis of the Cox regression model indicated that the expression of miR-6826 was the most significant predictor for overall survival (P=0.003, hazard ratio, 3.670). In conclusion, plasma miR-6826 and miR-6875 may be predictive biomarkers for a poor response to vaccine treatment. Although further clarification is needed regarding the functions of miR-6826 and miR-6875 and their relationship to immune‑related molecules, plasma miR-6826 and miR-6875 may be useful negative biomarkers for predicting the efficacy of vaccine treatment.

  19. Fluconazole penetration in cerebral parenchyma in humans at steady state.

    PubMed Central

    Thaler, F; Bernard, B; Tod, M; Jedynak, C P; Petitjean, O; Derome, P; Loirat, P

    1995-01-01

    We studied fluconazole penetration in the brain in five patients who had a deep cerebral tumor whose removal required the excision of healthy brain tissue. Plasma and brain samples were simultaneously obtained after oral ingestion of 400 mg of fluconazole daily for 4 days (90% of steady state). Fluconazole penetration in healthy cerebral parenchyma was determined. Plasma and brain samples were assayed by high-pressure liquid chromatography. Concentrations in plasma and brain tissue were 13.5 +/- 5.5 micrograms/ml and 17.6 +/- 6.6 micrograms/g, respectively. The average ratio of concentrations in the brain and plasma (four patients) was 1.33 (range, 0.70 to 2.39). Despite the lack of data concerning the penetration of fluconazole in brain abscesses, these results should permit the use of a daily dose of 400 mg of fluconazole in prospective clinical studies that evaluate the effectiveness of this drug in the treatment of brain abscesses due to susceptible species of fungi. PMID:7625804

  20. Comparison of some effects of modification of a polylactide surface layer by chemical, plasma, and laser methods

    NASA Astrophysics Data System (ADS)

    Moraczewski, Krzysztof; Rytlewski, Piotr; Malinowski, Rafał; Żenkiewicz, Marian

    2015-08-01

    The article presents the results of studies and comparison of selected properties of the modified PLA surface layer. The modification was carried out with three methods. In the chemical method, a 0.25 M solution of sodium hydroxide in water and ethanol was utilized. In the plasma method, a 50 W generator was used, which produced plasma in the air atmosphere under reduced pressure. In the laser method, a pulsed ArF excimer laser with fluency of 60 mJ/cm2 was applied. Polylactide samples were examined by using the following techniques: scanning electron microscopy (SEM), atomic force microscopy (AFM), goniometry and X-ray photoelectron spectroscopy (XPS). Images of surfaces of the modified samples were recorded, contact angles were measured, and surface free energy was calculated. Qualitative and quantitative analyses of chemical composition of the PLA surface layer were performed as well. Based on the survey it was found that the best modification results are obtained using the plasma method.

  1. Low gas flow inductively coupled plasma optical emission spectrometry for the analysis of food samples after microwave digestion.

    PubMed

    Nowak, Sascha; Gesell, Monika; Holtkamp, Michael; Scheffer, Andy; Sperling, Michael; Karst, Uwe; Buscher, Wolfgang

    2014-11-01

    In this work, the recently introduced low flow inductively coupled plasma optical emission spectrometry (ICP-OES) with a total argon consumption below 0.7 L/min is applied for the first time to the field of food analysis. One goal is the investigation of the performance of this low flow plasma compared to a conventional ICP-OES system when non-aqueous samples with a certain matrix are introduced into the system. For this purpose, arsenic is determined in three different kinds of fish samples. In addition several nutrients (K, Na, Mg, Ca) and trace metals (Co, Cu, Mn, Cd, Pb, Zn, Fe, and Ni) are determined in honey samples (acacia) after microwave digestion. The precision of the measurements is characterized by relative standard deviations (RSD) and compared to the corresponding precision values achieved using the conventional Fassel-type torch of the ICP. To prove the accuracy of the low flow ICP-OES method, the obtained data from honey samples are validated by a conventional ICP-OES. For the measurements concerning arsenic in fish, the low flow ICP-OES values are validated by conventional Fassel-type ICP-OES. Furthermore, a certified reference material was investigated with the low gas flow setup. Limits of detection (LOD), according to the 3σ criterion, were determined to be in the low microgram per liter range for all analytes. Recovery rates in the range of 96-106% were observed for the determined trace metal elements. It was proven that the low gas flow ICP-OES leads to results that are comparable with those obtained with the Fassel-type torch for the analysis of food samples. Copyright © 2014 Elsevier B.V. All rights reserved.

  2. Fe3O4@p-Naphtholbenzein as a novel nano-sorbent for highly effective removal and recovery of Berberine: Response surface methodology for optimization of ultrasound assisted dispersive magnetic solid phase extraction.

    PubMed

    Aghaie, Ali B G; Hadjmohammadi, Mohammad Reza

    2016-08-15

    A hydrophobic surface modified iron oxide magnetic nano-sorbent was successfully synthesized, characterized and utilized for highly effective removal and recovery of Berberine (Brb) by Ultrasound Assisted Dispersive Magnetic Solid Phase Extraction (UADM-SPE). Fabrication of p-Naphtholbenzein-coated magnetic nanoparticles (PNB-MNPs) was certified by characteristic analyses such as: Fourier transform infrared spectroscopy (FT-IR), X-ray Diffraction (XRD), thermogravimetric analysis (TGA), vibrating sample magnetometer (VSM), scanning electron microscopy (SEM), and transmission electron microscopy (TEM). The characterized PNB-MNPs were utilized to develop a UADM-SPE method for Brb, a well-known isoquinoline alkaloid with a highlighted chemical skeleton for designing selective and powerful bioactive molecules. Affecting parameters on the extraction of Brb were optimized through an orthogonal rotatable central composite design (CCD). The optimum condition is obtained when the variables are set to: pH=4, amount of MNPs=20mg, sample volume=30ml, sonication time=1min at room temperature, and desorbing solvent=500µL of methanol. Under the mentioned condition, an extraction recovery of 98.2%, with relative standard deviation of 3.7%, was obtained via five replicated measurements on a 0.1mgL(-1) Brb standard solution. Finally, the method was successfully applied for determination of Brb in human plasma and urine samples. Regarding the method calibration graphs in plasma and urine matrices, spiked in the range of 0.01-200.00µgL(-1), pre-concentration factors of 134 and 122, method detection limit (MDL) of 0.17 and 0.19µgL(-1), and lower limit of quantification of 0.57 and 0.63µgL(-1) were obtained for plasma and urine samples, respectively. The method exhibits good potentials to be a fast, efficient and reliable method for determination of Brb in human biological samples. Copyright © 2016 Elsevier B.V. All rights reserved.

  3. On quasi-thermal fluctuations near the plasma frequency in the outer plasmasphere: A case study

    NASA Technical Reports Server (NTRS)

    Lund, E. J.; Labelle, J.; Treumann, R. A.

    1994-01-01

    We present a derivation of the quasi-thermal electrostatic fluctuation power spectrum in a mult-Maxwellian plasma and show sample calculated spectra. We then apply this theory, which has been successfully applied in oter regions of space, to spectra from two Active Magnetospheric Particle Tracer Explorer/Ion Release Module (AMPTER IRM) passes through the duskside plasmasphere. WE show that the plasma line that is often seen in this region is usually quasi-thermal in origin. We obtain a refined estimate of the plasma frequency and infer a cold electron temperature which is consistent within a factor of 2 with both models and previous meausurements by other techniques, but closer investigation reveals that details of the plasma line cannot be explained with the ususal two isotropic Maxwellian model.

  4. Circulating DNA: a potential marker of sickle cell crisis.

    PubMed

    Vasavda, Nisha; Ulug, Pinar; Kondaveeti, Sheila; Ramasamy, Karthik; Sugai, Taku; Cheung, Gordon; Rees, David C; Awogbade, Moji; Bannister, Sybil; Cunningham, Juliette; Menzel, Stephan; Thein, Swee Lay

    2007-10-01

    Free circulating DNA is present in the plasma of healthy subjects, and is elevated in conditions characterized by increased cell death, such as cancer and physical trauma. Analysis of circulating DNA in plasma could provide a useful biomarker in sickle cell disease (SCD) in view of the increased cell turnover through chronic ongoing haemolysis, recurrent vaso-occlusion and inflammation. Plasma DNA was determined by real-time quantitative polymerase chain reaction (PCR) amplification of the beta-globin gene (HBB) in 154 patients with SCD [105 haemoglobin (Hb)SS, 46 HbSC and three HbS/beta(0) thalassaemia] and 53 ethnically matched controls. Blood samples were obtained from all patients in steady state; 21 of the 154 patients were also sampled during admission to hospital for acute pain. Median concentration of circulating plasma DNA in acute pain was more than 10-fold that in steady state and in controls - 10070 vs. 841 and 10070 vs. 933 genome equivalents/ml respectively (P < 0.0001, in both cases). During steady state, patients had plasma DNA levels similar to controls. Plasma DNA levels in SCD correlated with C-reactive protein levels (P < 0.005) and total white cell counts (P < 0.05) in steady state. The study shows that plasma DNA concentration may have potential as a biomarker in sickle cell patients.

  5. Improved Butanol-Methanol (BUME) Method by Replacing Acetic Acid for Lipid Extraction of Biological Samples.

    PubMed

    Cruz, Mutya; Wang, Miao; Frisch-Daiello, Jessica; Han, Xianlin

    2016-07-01

    Extraction of lipids from biological samples is a critical step in lipidomics, especially for shotgun lipidomics where lipid extracts are directly infused into a mass spectrometer. The butanol-methanol (BUME) extraction method was originally developed to extract lipids from plasma samples with 1 % acetic acid. Considering some lipids are sensitive to acidic environments, we modified this protocol by replacing acetic acid with lithium chloride solution and extended the modified extraction to tissue samples. Although no significant reduction of plasmalogen levels in the acidic BUME extracts of rat heart samples was found, the modified method was established to extract various tissue samples, including rat liver, heart, and plasma. Essentially identical profiles of the majority of lipid classes were obtained from the extracts of the modified BUME and traditional Bligh-Dyer methods. However, it was found that neither the original, nor the modified BUME method was suitable for 4-hydroxyalkenal species measurement in biological samples.

  6. Improved Butanol-Methanol (BUME) Method by Replacing Acetic Acid for Lipid Extraction of Biological Samples

    PubMed Central

    Cruz, Mutya; Wang, Miao; Frisch-Daiello, Jessica; Han, Xianlin

    2016-01-01

    Extraction of lipids from biological samples is a critical step in lipidomics, especially for shotgun lipidomics where lipid extracts are directly infused into a mass spectrometer. The butanol-methanol (BUME) extraction method was originally developed to extract lipids from plasma samples with 1% acetic acid. Considering some lipids are sensitive to acidic environments, we modified this protocol by replacing acetic acid with lithium chloride solution and extended the modified extraction to tissue samples. Although no significant reduction of plasmalogen levels in the acidic BUME extracts of rat heart samples was found, the modified method was established to extract various tissue samples, including rat liver, heart, and plasma. Essentially identical profiles of the majority of lipid classes were obtained from the extracts of the modified BUME and traditional Bligh-Dyer methods. However, it was found that neither the original, nor the modified BUME method was suitable for 4-hydroxyalkenal species measurement in biological samples. PMID:27245345

  7. Enfuvirtide cerebrospinal fluid (CSF) pharmacokinetics and potential use in defining CSF HIV-1 origin.

    PubMed

    Price, Richard W; Parham, Robin; Kroll, Jing Lu; Wring, Stephen A; Baker, Brian; Sailstad, Jeff; Hoh, Rebecca; Liegler, Teri; Spudich, Serena; Kuritzkes, Daniel R; Deeks, Steven G

    2008-01-01

    Enfuvirtide is a potent inhibitor of systemic HIV-1 replication, but its penetration into the human central nervous system (CNS) has not been analysed. Here, we define cerebrospinal fluid (CSF) enfuvirtide pharmacokinetics and present a case illustrating the use of enfuvirtide as a probe to trace the origins of CSF HIV-1 quasispecies. Enfuvirtide CSF pharmacokinetics were assessed in 18 CSF and plasma sample pairs from four HIV-1-infected individuals. Enfuvirtide levels were measured by liquid chromatography tandem mass spectrometry using known standards and controls that included spiked CSF samples from untreated, HIV-negative individuals. A segment of the gp41 coding region encompassing the heptad repeat HR-1 and HR-2 domains was amplified from selected CSF and plasma samples and independent clones sequenced to assess resistance-associated mutations. CSF and plasma samples obtained between 2 and 20 h after enfuvirtide injection showed plasma concentrations similar to previous reports (mean 3.687 SD +/- 1.828 mg/ml) with prolonged decay. By contrast, enfuvirtide in all CSF samples was below the assay detection limit of 0.025 mg/ml. In one individual, who developed a transient increase in CSF HIV-1 RNA, seven of seven CSF and plasma clones had identical enfuvirtide resistance-associated V38A mutations, suggesting that the CSF quasispecies derived from that of blood. Enfuvirtide penetration into CSF is negligible; thus, in clinical settings, where direct CNS drug exposure is crucial, this drug Is not likely to directly contribute to the local therapeutic effect. Enfuvirtide can be used as a tool to dissect the origin of the CNS virus.

  8. Bone marrow uptake of 99mTc-MIBI in patients with multiple myeloma.

    PubMed

    Fonti, R; Del Vecchio, S; Zannetti, A; De Renzo, A; Di Gennaro, F; Catalano, L; Califano, C; Pace, L; Rotoli, B; Salvatore, M

    2001-02-01

    In a previous study, we showed the ability of technetium-99m methoxyisobutylisonitrile (99mTc-MIBI) scan to identify active disease in patients with multiple myeloma (Eur J Nucl Med 1998; 25: 714-720). In particular, a semiquantitative score of the extension and intensity of bone marrow uptake was derived and correlated with both the clinical status of the disease and plasma cell bone marrow infiltration. In order to estimate quantitatively 99mTc-MIBI bone marrow uptake and to verify the intracellular localization of the tracer, bone marrow samples obtained from 24 multiple myeloma patients, three patients with monoclonal gammopathy of undetermined significance (MGUS) and two healthy donors were studied for in vitro uptake. After centrifugation over Ficoll-Hypaque gradient, cell suspensions were incubated with 99mTc-MIBI and the uptake was expressed as the percentage of radioactivity specifically retained within the cells. The cellular localization of the tracer was assessed by micro-autoradiography. Twenty-two out of 27 patients underwent 99mTc-MIBI scan within a week of bone marrow sampling. Whole-body images were obtained 10 min after intravenous injection of 555 MBq of the tracer; the extension and intensity of 99mTc-MIBI uptake were graded using the semiquantitative score. A statistically significant correlation was found between in vitro uptake of 99mTc-MIBI and both plasma cell infiltration (Pearson's coefficient of correlation r=0.69, P<0.0001) and in vivo score (Spearman rank correlation coefficient r=0.60, P<0.01). No specific tracer uptake was found in bone marrow samples obtained from the two healthy donors. Micro-autoradiography showed localization of 99mTc-MIBI inside the plasma cells infiltrating the bone marrow. Therefore, our findings show that the degree of tracer uptake both in vitro and in vivo is related to the percentage of infiltrating plasma cells which accumulate the tracer in their inner compartments.

  9. beta-hydroxy-beta-methylbutyrate (HMB) kinetics and the influence of glucose ingestion in humans.

    PubMed

    Vukovich, Matthew D.; Slater, Gary; Macchi, Martina B.; Turner, Michael J.; Fallon, Keiren; Boston, Tanya; Rathmacher, John

    2001-11-01

    The dietary supplement, beta-hydroxy-beta-methylbutyrate (HMB), has been shown to decrease muscle proteolysis during the stress of exercise and disease. The aim of this investigation was to determine the time course kinetics of HMB and to determine whether oral glucose ingestion alters the kinetics. In Study 1, eight males (32 +/- 10 yrs) participated in two randomize trials: 1) oral ingestion of 1g of HMB with water in capsule form (HMB), and 2) placebo. Blood samples were obtained prior to ingestion of treatment and at 30, 60, 90, 120, 150, and 180 min for the measurement of plasma HMB. Additional blood samples were obtained at 6, 9, and 12 hr. Urine was collected prior to ingestion and at 3, 6, 9, and 12 h for the measurement of urinary HMB. In Study 2, eight males (25 +/- 6 yrs) followed the same study design and testing procedure as for Study 1. Treatments were 1) modified glucose tolerance test (75 g glucose) (GLU), 2) oral ingestion of 3 g of HMB with water (HMB), and 3) ingestion of 3 g of HMB with 75 g of glucose (HMB+GLU). Blood samples were analyzed for insulin, glucose, and HMB. Additional blood samples were obtained at 24h and 36h for the measurement of HMB. Additional urine samples were collected at 24h and 36h. In Study 1, plasma HMB peaked at 120 nmol/ml at 2.0 +/- 0.4 hr in HMB trial. Half-life was 2.37 +/- 0.1 hr. Following the consumption of 1g of HMB, approximately 14% of the HMB consumed accumulated in the urine. In Study 2, plasma glucose and insulin levels were significantly greater in GLU and HMB+GLU treated subjects compared to HMB treated subject at minutes 30, 60 and 90. Plasma HMB peaked at 487.9 +/- 19.0 nmol/ml at 1.0 +/- 0.1 hr in the HMB treated subjects and at 352.1 +/- 15.3 nmol/ml at 1.94 +/- 0.2 hr when subjects consumed HMB+GLU. The time to reach peak was different (P <0.001) between HMB and HMB+GLU. The plasma HMB half-life was less (P = 0.08) 2.38 +/- 0.1 hr in HMB trial compared to 2.69 +/- 0.2 hr in HMB+GLU trial. Area under the plasma HMB curve during the first 3 hr was less (P = 0.002) in the HMB+GLU trial compared to the HMB trial. From 3 h through 36 h the area under the HMB curve tended to be less (P = 0.106) for the HMB+GLU compared to the HMB alone. HMB accumulation in the urine as well as the area under the curve were similar with both HMB (94875.8 +/- 15159.5 nmol/36 hrs) and HMB+GLU (80678.2 +/- 3863.1 nmol/36 hrs). The percentage of the HMB dose that accumulates in the urine was 27% for HMB+GLU and 29% for HMB alone. In conclusion, HMB plasma levels peak within 60 to 120 min depending on the amount of HMB consumed and whether glucose is consumed with HMB. The plasma half-life is approximately 2.5 hr. Plasma HMB reaches baseline levels at approximately 9 hr following ingestion. However, 70 to 85% of the ingested oral HMB is retained in the body for further metabolism.

  10. The influence of storage time and temperature on the measurement of serum, plasma and urine osmolality.

    PubMed

    Bezuidenhout, Karla; Rensburg, Megan A; Hudson, Careen L; Essack, Younus; Davids, M Razeen

    2016-07-01

    Many clinical laboratories require that specimens for serum and urine osmolality determination be processed within 3 h of sampling or need to arrive at the laboratory on ice. This protocol is based on the World Health Organization report on sample storage and stability, but the recommendation lacks good supporting data. We studied the effect of storage temperature and time on osmolality measurements. Blood and urine samples were obtained from 16 patients and 25 healthy volunteers. Baseline serum, plasma and urine osmolality measurements were performed within 30 min. Measurements were then made at 3, 6, 12, 24 and 36 h on samples stored at 4-8℃ and room temperature. We compared baseline values with subsequent measurements and used difference plots to illustrate changes in osmolality. At 4-8℃, serum and plasma osmolality were stable for up to 36 h. At room temperature, serum and plasma osmolality were very stable for up to 12 h. At 24 and 36 h, changes from baseline osmolality were statistically significant and exceeded the total allowable error of 1.5% but not the reference change value of 4.1%. Urine osmolality was extremely stable at room temperature with a mean change of less than 1 mosmol/kg at 36 h. Serum and plasma samples can be stored at room temperature for up to 36 h before measuring osmolality. Cooling samples to 4-8℃ may be useful when delays in measurement beyond 12 h are anticipated. Urine osmolality is extremely stable for up to 36 h at room temperature. © The Author(s) 2015.

  11. A reliable and rapid tool for plasma quantification of 18 psychotropic drugs by ESI tandem mass spectrometry.

    PubMed

    Vecchione, Gennaro; Casetta, Bruno; Chiapparino, Antonella; Bertolino, Alessandro; Tomaiuolo, Michela; Cappucci, Filomena; Gatta, Raffaella; Margaglione, Maurizio; Grandone, Elvira

    2012-01-01

    A simple liquid chromatographic tandem mass spectrometry (LC-MS/MS) method has been developed for simultaneous analysis of 17 basic and one acid psychotropic drugs in human plasma. The method relies on a protein precipitation step for sample preparation and offers high sensitivity, wide linearity without interferences from endogenous matrix components. Chromatography was run on a reversed-phase column with an acetonitrile-H₂O mixture. The quantification of target compounds was performed in multiple reaction monitoring (MRM) and by switching the ionization polarity within the analytical run. A further sensitivity increase was obtained by implementing the functionality "scheduled multiple reaction monitoring" (sMRM) offered by the recent version of the software package managing the instrument. The overall injection interval was less than 5.5 min. Regression coefficients of the calibration curves and limits of quantification (LOQ) showed a good coverage of over-therapeutic, therapeutic and sub-therapeutic ranges. Recovery rates, measured as percentage of recovery of spiked plasma samples, were ≥ 94%. Precision and accuracy data have been satisfactory for a therapeutic drug monitoring (TDM) service as for managing plasma samples from patients receiving psycho-pharmacological treatment. Copyright © 2012 Elsevier B.V. All rights reserved.

  12. Impression of plasma voltage on growth of α-V{sub 2}O{sub 5} nanostructured thin films

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sharma, Rabindar Kumar, E-mail: rkrksharma6@gmail.com; Kumar, Prabhat; Reddy, G. B.

    2015-06-24

    In this communication, we synthesized vanadium pentoxide (α-V{sub 2}O{sub 5}) nanostructured thin films (NST{sub s}) accompanied with nanoflakes/ nanoplates on the Ni-coated glass substrates employing plasma assisted sublimation process (PASP) as a function of plasma voltage (V{sub p}). The effect of plasma voltage on structural, morphological, compositional, and vibrational properties have been studied systematically. The structural analysis divulged that all films deposited at different V{sub p} have pure orthorhombic phase, no impurity phase is detected under resolution limit of XRD and XPS. The morphological studies of samples is carried out by SEM, revealed that features as well as alignment ofmore » V{sub 2}O{sub 5} NST{sub s} is greatly monitored by V{sub p} and the film possessing the best features is obtained at 2500volt. In addition, XPS results reveal that V{sup 5+} oxidation state is the most prominent state in sample V{sub 2}, which represents better stoichiometric nature of film. The vibrational study of all samples is performed by FTIR and strongly support the XRD observations. All the results are in consonance with each other.« less

  13. Biological application of laser induced breakdown spectroscopy technique for determination of trace elements in hair.

    PubMed

    Emara, Elshaimaa M; Imam, Hisham; Hassan, Mouyed A; Elnaby, Salah H

    2013-12-15

    Analysis of trace elements in mammalian hair has the potential to reveal retrospective information about an individual's nutritional status and exposure. As trace elements are incorporated into the hair during the growth process, longitudinal segments of the hair may reflect the body burden during growth. Using LIBS technique, Na, K, Ca, Mg, Si, Fe, Pb and Zn were detected in a single strand of horse hair. The results obtained through LIBS technique on hair samples were compared with the traditional technique (AAS) on digested acidified solution of the same samples. The effects of the experimental parameters on the emission lines were studied and the local thermodynamic equilibrium (LTE) in produced plasma was investigated. The transient plasma condition was verified at specific time region (1500-2000 ns) in the plasma evolution corresponding to its dynamic expanding characteristic. The relative mass concentrations of Fe and Zn were calculated by setting the concentration of C as the calibration. The information obtained from the trace elements' spectra of horse hair in this study substantiates the potential of hair as a biomarker. © 2013 Elsevier B.V. All rights reserved.

  14. Impact energy and retained dose uniformity in enhanced glow discharge plasma immersion ion implantation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lu, Q. Y.; Fu, Ricky K. Y.; Chu, Paul K.

    2009-08-10

    The implantation energy and retained dose uniformity in enhanced glow discharge plasma immersion ion implantation (EGD-PIII) is investigated numerically and experimentally. Depth profiles obtained from different samples processed by EGD-PIII and traditional PIII are compared. The retained doses under different pulse widths are calculated by integrating the area under the depth profiles. Our results indicate that the improvement in the impact energy and retained dose uniformity by this technique is remarkable.

  15. Alpha-spectrometry and fractal analysis of surface micro-images for characterisation of porous materials used in manufacture of targets for laser plasma experiments

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Aushev, A A; Barinov, S P; Vasin, M G

    2015-06-30

    We present the results of employing the alpha-spectrometry method to determine the characteristics of porous materials used in targets for laser plasma experiments. It is shown that the energy spectrum of alpha-particles, after their passage through porous samples, allows one to determine the distribution of their path length in the foam skeleton. We describe the procedure of deriving such a distribution, excluding both the distribution broadening due to statistical nature of the alpha-particle interaction with an atomic structure (straggling) and hardware effects. The fractal analysis of micro-images is applied to the same porous surface samples that have been studied bymore » alpha-spectrometry. The fractal dimension and size distribution of the number of the foam skeleton grains are obtained. Using the data obtained, a distribution of the total foam skeleton thickness along a chosen direction is constructed. It roughly coincides with the path length distribution of alpha-particles within a range of larger path lengths. It is concluded that the combined use of the alpha-spectrometry method and fractal analysis of images will make it possible to determine the size distribution of foam skeleton grains (or pores). The results can be used as initial data in theoretical studies on propagation of the laser and X-ray radiation in specific porous samples. (laser plasma)« less

  16. Total plasma proANP increases with atrial dilatation in horses.

    PubMed

    Van Der Vekens, N; Hunter, I; Timm, A; Decloedt, A; De Clercq, D; Deprez, P; Goetze, J P; van Loon, G

    2015-12-19

    Equine atrial natriuretic peptide (ANP) plasma concentrations are correlated with left atrial size. However, species-specific assays are lacking and the results from human assays are poorly reproducible. A new methodology called processing independent analysis (PIA) that measures the total proANP product in plasma has proven to be successful in human medicine, but has never been used in horses. The aims were to establish an equine proANP reference interval by measurement of the total proANP product using PIA and to examine the proANP concentrations in horses with atrial dilatation. Sample stability was studied by comparison of storage at -80°C and -20°C. Plasma samples were obtained from 23 healthy horses, 12 horses with moderate or severe valvular regurgitation without atrial dilatation and 42 horses with valvular regurgitation and atrial dilatation. The proANP concentration was significantly (P<0.001) higher in horses with atrial dilatation (761.4 (442.1-1859.1) pmol/l) than in healthy horses (491.6 (429.5-765.9) pmol/l; P<0.001) or horses with cardiac disease but without atrial dilatation (544.4 (457.0-677.6) pmol/l). A cut-off value (573.8 pmol/l) for detection of atrial dilatation was calculated. Sample storage at -80°C did not differ from sample storage at -20°C. The measurement of total proANP in plasma detects atrial dilatation in horses and may be useful for clinical evaluation in equine medicine. British Veterinary Association.

  17. The Neutral Gas Desorption and Breakdown on a Metal-Dielectric Junction Immersed in a Plasma

    NASA Technical Reports Server (NTRS)

    Vayner, Boris; Galofaro, Joel; Ferguson, Dale; Lyons, Valerie J. (Technical Monitor)

    2002-01-01

    New results are presented of an experimental study and theoretical analysis of arcing on metal-dielectric junctions immersed in a low-density plasma. Two samples of conventional solar arrays have been used to investigate the effects of arcing within a wide range of neutral gas pressures, ion currents, and electron number densities. All data (except video) were obtained in digital form that allowed us to study the correlation between external parameters (plasma density, additional capacitance, bias voltage, etc) and arc characteristics (arc rate, arc current pulse width and amplitude, gas species partial pressures, intensities of spectral lines, and so on). Arc sites were determined by employing a video-camera, and it is shown that the most probable sites for arc inception are trip le-junctions, even though some arcs were initiated in gaps between cells. The effect of surface conditioning (decrease of arc rate due to outgassing) was clearly demonstrated. Moreover, a considerable increase in arc rate due to absorption of molecules from atmospheric air has been confirmed. The analysis of optical spectra (240-800 nm) reveals intense narrow atomic lines (Ag, H) and wide molecular bands (OH, CH, SiH, SiN) that confirm a complicated mechanism of arc plasma generation. The rate of plasma contamination due to arcing was measured by employing a mass-spectrometer. These measurements provided quite reliable data for the development of a theoretical model of plasma contamination, In conclusion, the arc threshold was increased to above 350 V (from 190 V) by keeping a sample in vacuum (20 micronTorr) for seven days. The results obtained are important for the understanding of the arc inception mechanism, which is absolutely essential for progress toward the design of high voltage solar arrays for space applications.

  18. Macrophage Migration Inhibitory Factor for the Early Prediction of Infarct Size

    PubMed Central

    Chan, William; White, David A.; Wang, Xin‐Yu; Bai, Ru‐Feng; Liu, Yang; Yu, Hai‐Yi; Zhang, You‐Yi; Fan, Fenling; Schneider, Hans G.; Duffy, Stephen J.; Taylor, Andrew J.; Du, Xiao‐Jun; Gao, Wei; Gao, Xiao‐Ming; Dart, Anthony M.

    2013-01-01

    Background Early diagnosis and knowledge of infarct size is critical for the management of acute myocardial infarction (MI). We evaluated whether early elevated plasma level of macrophage migration inhibitory factor (MIF) is useful for these purposes in patients with ST‐elevation MI (STEMI). Methods and Results We first studied MIF level in plasma and the myocardium in mice and determined infarct size. MI for 15 or 60 minutes resulted in 2.5‐fold increase over control values in plasma MIF levels while MIF content in the ischemic myocardium reduced by 50% and plasma MIF levels correlated with myocardium‐at‐risk and infarct size at both time‐points (P<0.01). In patients with STEMI, we obtained admission plasma samples and measured MIF, conventional troponins (TnI, TnT), high sensitive TnI (hsTnI), creatine kinase (CK), CK‐MB, and myoglobin. Infarct size was assessed by cardiac magnetic resonance (CMR) imaging. Patients with chronic stable angina and healthy volunteers were studied as controls. Of 374 STEMI patients, 68% had elevated admission MIF levels above the highest value in healthy controls (>41.6 ng/mL), a proportion similar to hsTnI (75%) and TnI (50%), but greater than other biomarkers studied (20% to 31%, all P<0.05 versus MIF). Only admission MIF levels correlated with CMR‐derived infarct size, ventricular volumes and ejection fraction (n=42, r=0.46 to 0.77, all P<0.01) at 3 day and 3 months post‐MI. Conclusion Plasma MIF levels are elevated in a high proportion of STEMI patients at the first obtainable sample and these levels are predictive of final infarct size and the extent of cardiac remodeling. PMID:24096574

  19. Toxicokinetics of perfluorooctane sulfonate in rainbow trout (Oncorhynchus mykiss)

    EPA Science Inventory

    Rainbow trout (Oncorhynchus mykiss) confined to respirometer-metabolism chambers were dosed with perfluorooctane sulfonate (PFOS) by intra-arterial injection and sampled to obtain concentration time-course data for plasma, and either urine or expired water. The data were then an...

  20. A comparative study of thermochemical and cold plasma treatment on lignin-based activated carbon for adsorbing Fe(III)

    NASA Astrophysics Data System (ADS)

    Shi, Shukai; Wang, Xin; Chen, Weimin; Chen, Minzhi; Zhou, Xiaoyan

    2018-05-01

    The as-prepared lignin-based activated carbon (LAC) was post-treated by urea and radio-frequency cold plasma separately. The obtained results demonstrated that the BET surface and total volumes of the LAC and plasma-treated LACs were greater than the urea-modified sample. The analysis of surface elemental composition showed that the nitrogen content of urea-modified LAC and nitrogen plasma-treated LAC are 3.79% and 2.62% higher than that of original LAC respectively, while the oxygen content of air plasma-treated LAC is 10.23% higher than that of original LAC. The Fe(III) ions adsorbed studies with pseudo-second order kinetic model revealed that urea-modified LAC had faster chemisorption rates while air plasma-treated LAC had larger adsorption capacity within 3 h. Moreover, the adsorption capacity and chemisorption rates of LAC post-treated by nitrogen plasma are inferior to the air plasma-treated LAC.

  1. Development of a gas-cylinder-free plasma desorption/ionization system for on-site detection of chemical warfare agents.

    PubMed

    Iwai, Takahiro; Kakegawa, Ken; Aida, Mari; Nagashima, Hisayuki; Nagoya, Tomoki; Kanamori-Kataoka, Mieko; Miyahara, Hidekazu; Seto, Yasuo; Okino, Akitoshi

    2015-06-02

    A gas-cylinder-free plasma desorption/ionization system was developed to realize a mobile on-site analytical device for detection of chemical warfare agents (CWAs). In this system, the plasma source was directly connected to the inlet of a mass spectrometer. The plasma can be generated with ambient air, which is drawn into the discharge region by negative pressure in the mass spectrometer. High-power density pulsed plasma of 100 kW could be generated by using a microhollow cathode and a laboratory-built high-intensity pulsed power supply (pulse width: 10-20 μs; repetition frequency: 50 Hz). CWAs were desorbed and protonated in the enclosed space adjacent to the plasma source. Protonated sample molecules were introduced to the mass spectrometer by airflow through the discharge region. To evaluate the analytical performance of this device, helium and air plasma were directly irradiated to CWAs in the gas-cylinder-free plasma desorption/ionization system and the protonated molecules were analyzed by using an ion-trap mass spectrometer. A blister agent (nitrogen mustard 3) and nerve gases [cyclohexylsarin (GF), tabun (GA), and O-ethyl S-2-N,N-diisopropylaminoethyl methylphosphonothiolate (VX)] in solution in n-hexane were applied to the Teflon rod and used as test samples, after solvent evaporation. As a result, protonated molecules of CWAs were successfully observed as the characteristic ion peaks at m/z 204, 181, 163, and 268, respectively. In air plasma, the limits of detection were estimated to be 22, 20, 4.8, and 1.0 pmol, respectively, which were lower than those obtained with helium plasma. To achieve quantitative analysis, calibration curves were made by using CWA stimulant dipinacolyl methylphosphonate as an internal standard; straight correlation lines (R(2) = 0.9998) of the peak intensity ratios (target per internal standard) were obtained. Remarkably, GA and GF gave protonated dimer ions, and the ratios of the protonated dimer ions to the protonated monomers increased with the amount of GA and GF applied.

  2. Validation of the determination of the B isotopic composition in Roman glasses with laser ablation multi-collector inductively coupled plasma-mass spectrometry

    NASA Astrophysics Data System (ADS)

    Devulder, Veerle; Gerdes, Axel; Vanhaecke, Frank; Degryse, Patrick

    2015-03-01

    The applicability of laser ablation multi-collector inductively coupled plasma-mass spectrometry (LA-MC-ICP-MS) for the determination of the B isotopic composition in Roman glasses was investigated. The δ11B values thus obtained provide information on the natron flux used during the glass-making process. The glass samples used for this purpose were previously characterized using pneumatic nebulization (PN) MC-ICP-MS. Unfortunately, this method is time-consuming and labor-intensive and consumes some 100 mg of sample, which is a rather high amount for ancient materials. Therefore, the use of the less invasive and faster LA-MC-ICP-MS approach was explored. In this work, the results for 29 Roman glasses and 4 home-made glasses obtained using both techniques were compared to assess the suitability of LA-MC-ICP-MS in this context. The results are in excellent agreement within experimental uncertainty. No difference in overall mass discrimination was observed between the Roman glasses, NIST SRM 610 reference glass and B6 obsidian. The expanded uncertainty of the LA-MC-ICP-MS approach was estimated to be < 2‰, which is similar to that obtained upon sample digestion and PN-MC-ICP-MS measurement.

  3. Quantification of 18F-fluorocholine kinetics in patients with prostate cancer.

    PubMed

    Verwer, Eline E; Oprea-Lager, Daniela E; van den Eertwegh, Alfons J M; van Moorselaar, Reindert J A; Windhorst, Albert D; Schwarte, Lothar A; Hendrikse, N Harry; Schuit, Robert C; Hoekstra, Otto S; Lammertsma, Adriaan A; Boellaard, Ronald

    2015-03-01

    Choline kinase is upregulated in prostate cancer, resulting in increased (18)F-fluoromethylcholine uptake. This study used pharmacokinetic modeling to validate the use of simplified methods for quantification of (18)F-fluoromethylcholine uptake in a routine clinical setting. Forty-minute dynamic PET/CT scans were acquired after injection of 204 ± 9 MBq of (18)F-fluoromethylcholine, from 8 patients with histologically proven metastasized prostate cancer. Plasma input functions were obtained using continuous arterial blood-sampling as well as using image-derived methods. Manual arterial blood samples were used for calibration and correction for plasma-to-blood ratio and metabolites. Time-activity curves were derived from volumes of interest in all visually detectable lymph node metastases. (18)F-fluoromethylcholine kinetics were studied by nonlinear regression fitting of several single- and 2-tissue plasma input models to the time-activity curves. Model selection was based on the Akaike information criterion and measures of robustness. In addition, the performance of several simplified methods, such as standardized uptake value (SUV), was assessed. Best fits were obtained using an irreversible compartment model with blood volume parameter. Parent fractions were 0.12 ± 0.4 after 20 min, necessitating individual metabolite corrections. Correspondence between venous and arterial parent fractions was low as determined by the intraclass correlation coefficient (0.61). Results for image-derived input functions that were obtained from volumes of interest in blood-pool structures distant from tissues of high (18)F-fluoromethylcholine uptake yielded good correlation to those for the blood-sampling input functions (R(2) = 0.83). SUV showed poor correlation to parameters derived from full quantitative kinetic analysis (R(2) < 0.34). In contrast, lesion activity concentration normalized to the integral of the blood activity concentration over time (SUVAUC) showed good correlation (R(2) = 0.92 for metabolite-corrected plasma; 0.65 for whole-blood activity concentrations). SUV cannot be used to quantify (18)F-fluoromethylcholine uptake. A clinical compromise could be SUVAUC derived from 2 consecutive static PET scans, one centered on a large blood-pool structure during 0-30 min after injection to obtain the blood activity concentrations and the other a whole-body scan at 30 min after injection to obtain lymph node activity concentrations. © 2015 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  4. MAC reduction of isoflurane by sufentanil.

    PubMed

    Brunner, M D; Braithwaite, P; Jhaveri, R; McEwan, A I; Goodman, D K; Smith, L R; Glass, P S

    1994-01-01

    We have shown previously that a plasma fentanyl concentration of 1.67 ng ml-1 reduced the MAC of isoflurane by 50%. By comparing equal degrees of MAC reduction by sufentanil, we may determine the potency ratio of these opioids. Seventy-six patients were allocated randomly to receive predetermined infusions of sufentanil, and end-tidal concentrations of isoflurane in oxygen. Blood samples were obtained 10 min after the start of the infusion, and just before and after skin incision. Any purposeful movement by the patient was recorded. The MAC reduction of isoflurane produced by sufentanil was obtained using a logistic regression model. A sufentanil plasma concentration of 0.145 ng ml-1 (95% confidence limits 0.04, 0.26 ng ml-1) resulted in a 50% reduction in the MAC of isoflurane. At a plasma concentration greater than 0.5 ng ml-1, sufentanil exhibited a ceiling effect.

  5. Monitoring disease progression with plasma creatinine in amyotrophic lateral sclerosis clinical trials

    PubMed Central

    van Eijk, Ruben P A; Eijkemans, Marinus J C; Ferguson, Toby A; Nikolakopoulos, Stavros; Veldink, Jan H; van den Berg, Leonard H

    2018-01-01

    Objectives Plasma creatinine is a predictor of survival in amyotrophic lateral sclerosis (ALS). It remains, however, to be established whether it can monitor disease progression and serve as surrogate endpoint in clinical trials. Methods We used clinical trial data from three cohorts of clinical trial participants in the LITRA, EMPOWER and PROACT studies. Longitudinal associations between functional decline, muscle strength and survival with plasma creatinine were assessed. Results were translated to trial design in terms of sample size and power. Results A total of 13 564 measurements were obtained for 1241 patients. The variability between patients in rate of decline was lower in plasma creatinine than in ALS functional rating scale–Revised (ALSFRS-R; p<0.001). The average rate of decline was faster in the ALSFRS-R, with less between-patient variability at baseline (p<0.001). Plasma creatinine had strong longitudinal correlations with the ALSFRS-R (0.43 (0.39–0.46), p<0.001), muscle strength (0.55 (0.51–0.58), p<0.001) and overall mortality (HR 0.88 (0.86–0.91, p<0.001)). Using plasma creatinine as outcome could reduce the sample size in trials by 21.5% at 18 months. For trials up to 10 months, the ALSFRS-R required a lower sample size. Conclusions Plasma creatinine is an inexpensive and easily accessible biomarker that exhibits less variability between patients with ALS over time and is predictive for the patient’s functional status, muscle strength and mortality risk. Plasma creatinine may, therefore, increase the power to detect treatment effects and could be incorporated in future ALS clinical trials as potential surrogate outcome. PMID:29084868

  6. Human herpesvirus infections of the central nervous system: laboratory diagnosis based on DNA detection by nested PCR in plasma and cerebrospinal fluid samples.

    PubMed

    Rimério, Carla Aparecida Tavares; De Oliveira, Renato Souza; de Almeida Bonatelli, Murilo Queiroz; Nucci, Anamarli; Costa, Sandra Cecília Botelho; Bonon, Sandra Helena Alves

    2015-04-01

    Infections of the central nervous systems (CNS) present a diagnostic problem for which an accurate laboratory diagnosis is essential. Invasive practices, such as cerebral biopsy, have been replaced by obtaining a polymerase chain reaction (PCR) diagnosis using cerebral spinal fluid (CSF) as a reference method. Tests on DNA extracted from plasma are noninvasive, thus avoiding all of the collateral effects and patient risks associated with CSF collection. This study aimed to determine whether plasma can replace CSF in nested PCR analysis for the detection of CNS human herpesvirus (HHV) diseases by analysing the proportion of patients whose CSF nested PCR results were positive for CNS HHV who also had the same organism identified by plasma nested PCR. In this study, CSF DNA was used as the "gold standard," and nested PCR was performed on both types of samples. Fifty-two patients with symptoms of nervous system infection were submitted to CSF and blood collection. For the eight HHV, one positive DNA result-in plasma and/or CSF nested PCR-was considered an active HHV infection, whereas the occurrence of two or more HHVs in the same sample was considered a coinfection. HHV infections were positively detected in 27/52 (51.9%) of the CSF and in 32/52 (61.5%) of the plasma, difference not significant, thus nested PCR can be performed on plasma instead of CSF. In conclusion, this findings suggest that plasma as a useful material for the diagnosis of cases where there is any difficulty to perform a CSF puncture. © 2015 Wiley Periodicals, Inc.

  7. Sensitive and rapid liquid chromatography/tandem mass spectrometric assay for the quantification of piperaquine in human plasma.

    PubMed

    Singhal, Puran; Gaur, Ashwani; Gautam, Anirudh; Varshney, Brijesh; Paliwal, Jyoti; Batra, Vijay

    2007-11-01

    A simple, sensitive and rapid liquid chromatography/tandem mass spectrometric (LC-MS/MS) method was developed and validated for quantification of piperaquine, an antimalarial drug, in human plasma using its structural analogue, piperazine bis chloroquinoline as internal standard (IS). The method involved a simple protein precipitation with methanol followed by rapid isocratic elution of analytes with 10mM ammonium acetate buffer/methanol/formic acid/ammonia solution (25/75/0.2/0.15, v/v) on Chromolith SpeedROD RP-18e reversed phase chromatographic column and quantification by mass spectrometry in the multiple reaction monitoring mode (MRM). The precursor to product ion transitions of m/z 535.3-->288.2 and m/z 409.1-->205.2 were used to measure the analyte and the IS, respectively. The assay exhibited a linear dynamic range of 1.0-250.2 ng/mL for piperaquine in plasma. The limit of detection (LOD) and lower limit of quantification (LLOQ) in plasma were 0.2 and 1.0 ng/mL, respectively. Acceptable precision and accuracy (+/-20% deviation for LLOQ standard and +/-15% deviation for other standards from the respective nominal concentration) were obtained for concentrations over the standard curve ranges. A run time of 2.5 min for a sample made it possible to achieve a throughput of more than 400 plasma samples analyzed per day. The validated method was successfully applied to analyze human plasma samples from phase-1 clinical studies. The mean pharmacokinetic parameters of piperaquine following 1000 mg oral dose: observed maximum plasma concentration (Cmax), time to maximum plasma concentration (Tmax) and elimination half-life (T1/2) were 46.1 ng/mL, 3.8h and 13 days, respectively.

  8. Improved microwave shielding behavior of carbon nanotube-coated PET fabric using plasma technology

    NASA Astrophysics Data System (ADS)

    Haji, Aminoddin; Semnani Rahbar, Ruhollah; Mousavi Shoushtari, Ahmad

    2014-08-01

    Four different procedures were conducted to load amine functionalized multiwall carbon nanotube (NH2-MWCNT) onto poly (ethylene terephthalate) (PET) fabric surface to obtain a microwave shielding sample. Plasma treated fabric which was subsequently coated with NH2-MWCNT in the presence of acrylic acid was chosen as the best sample. Surface changes in the PET fabrics were investigated by X-ray photoelectron spectroscopy (XPS) and scanning electron microscopy (SEM). Wide-angle X-ray diffraction was used to study the crystalline structure of the PET fabric. The microwave shielding performance of the PET fabrics in term of reflection loss was determined using a network analyzer at X-band (8.2-12.4 GHz). The XPS results revealed that the carbon atomic percentage decreased while the oxygen atomic percentage increased when the fabric was plasma treated and coated with NH2-MWCNT. The SEM images showed that the NH2-MWCNTs were homogenously dispersed and individually separated in the surface of fabric. Moreover, the structural studies showed that the crystalline region of the fabrics was not affected by NH2-MWCNT and plasma treatment. The best microwave absorbing properties were obtained from the plasma treated fabric which was then coated with 10% NH2-MWCNT in the presence of acrylic acid. It showed a minimum reflection loss of ∼-18.2 dB about 11 GHz. Proper attachments of NH2-MWCNT on the PET fabric surface was explained in the suggested mechanism in which hydrogen bonding and amide linkage are responsible for the achievement of microwave shielding properties with high durability.

  9. Qualitative and quantitative spectro-chemical analysis of dates using UV-pulsed laser induced breakdown spectroscopy and inductively coupled plasma mass spectrometry.

    PubMed

    Mehder, A O; Habibullah, Y B; Gondal, M A; Baig, Umair

    2016-08-01

    Laser Induced Breakdown Spectroscopy (LIBS) is demonstrated for the spectral analysis of nutritional and toxic elements present in several varieties of date fruit samples available in the Saudi Arabia market. The method analyzes the optical emission of a test sample when subjected to pulsed laser ablation. In this demonstration, our primary focus is on calcium (Ca) and magnesium (Mg), as nutritional elements, and on chromium (Cr), as a toxic element. The local thermodynamic equilibrium (LTE) condition was confirmed prior to the elemental characterization of date samples to ensure accuracy of the LIBS analysis. This was achieved by measuring parameters associated with the plasma, such as the electron temperature and the electron number density. These plasma parameters aid interpretation of processes such as ionization, dissociation, and excitation occurring in the plasma plume formed by ablating the date palm sample. The minimum detection limit was established from calibration curves that involved plotting the LIBS signal intensity as a function of standard date samples with known concentrations. The concentration of Ca and Mg detected in different varieties of date samples was between 187 and 515 and 35-196mgL(-1) respectively, while Cr concentration measured between 1.72 and 7.76mgL(-1). In order to optimize our LIBS system, we have studied how the LIBS signal intensity depends on the incident laser energy and the delay time. In order to validate our LIBS analysis results, standard techniques such as inductively coupled plasma mass spectrometry (ICP-MS) were also applied on an identical (duplicate) date samples as those used for the LIBS analysis. The LIBS results exhibit remarkable agreement with those obtained from the ICP-MS analysis. In addition, the finger print wavelengths of other elements present in date samples were also identified and are reported here, which has not been previously reported, to the best of our knowledge. Copyright © 2016 Elsevier B.V. All rights reserved.

  10. A simple high performance liquid chromatography method for determination of rebamipide in rat urine.

    PubMed

    Cooper, Dustin L; Harirforoosh, Sam

    2014-01-01

    Rebamipide is a mucoprotective agent commonly used to prevent nonsteriodal anti-inflammatory drug-induced gastrointenstinal side effects [1]. Human plasma and urine analysis of rebamipide utilizing high performance liquid chromatography (HPLC) have been reported [2]. Recently, we reported on the plasma levels of rebamipide in presense or absence of celecoxib or diclofenac in rats [3] using a modified HPLC method of detection developed by Jeoung et al. [4]. To tailor the method towards use in urinary rebamipide extraction and analysis, the following modifications were made:•To compensate for high concentrations of rebamipide found in urine, a new rebamipide stock solution was prepared with a final concentration of 50,000 ng/mL.•Rat urine calibration standards were obtained within the range of 50-1000 ng/mL and 1000-50,000 ng/mL.•Plasma samples were replaced with urine samples.

  11. Tungsten nitride coatings obtained by HiPIMS as plasma facing materials for fusion applications

    NASA Astrophysics Data System (ADS)

    Tiron, Vasile; Velicu, Ioana-Laura; Porosnicu, Corneliu; Burducea, Ion; Dinca, Paul; Malinský, Petr

    2017-09-01

    In this work, tungsten nitride coatings with nitrogen content in the range of 19-50 at% were prepared by reactive multi-pulse high power impulse magnetron sputtering as a function of the argon and nitrogen mixture and further exposed to a deuterium plasma jet. The elemental composition, morphological properties and physical structure of the samples were investigated by Rutherford backscattering spectrometry, atomic force microscopy and X-ray diffraction. Deuterium implantation was performed using a deuterium plasma jet and its retention in nitrogen containing tungsten films was investigated using thermal desorption spectrometry. Deuterium retention and release behaviour strongly depend on the nitrogen content in the coatings and the films microstructure. All nitride coatings have a polycrystalline structure and retain a lower deuterium level than the pure tungsten sample. Nitrogen content in the films acts as a diffusion barrier for deuterium and leads to a higher desorption temperature, therefore to a higher binding energy.

  12. Arc Inception Mechanism on a Solar Array Immersed in a Low-Density Plasma

    NASA Technical Reports Server (NTRS)

    Vayner, B.; Galofaro, J.; Ferguson, D.

    2001-01-01

    In this report, results are presented of an experimental and theoretical study of arc phenomena and snapover for two samples of solar arrays immersed in argon plasma. The effects of arcing and snapover are investigated. I-V curves are measured, and arc and snapover inception voltages and arc rates are determined within the wide range of plasma parameters. A considerable increase in arc rate due to absorption of molecules from atmospheric air has been confirmed. It is shown that increasing gas pressure causes increasing ion current collection and, consequently, arc rate even though the effect of conditioning also takes place. Arc sites have been determined by employing a video-camera. It is confirmed that keeping sample under high vacuum for a long time results in shifting arc threshold voltage well below -300 V. The results obtained seem to be important for the understanding of arc inception mechanism.

  13. Plasma immersion ion implantation for reducing metal ion release

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Diaz, C.; Garcia, J. A.; Maendl, S.

    Plasma immersion ion implantation of Nitrogen and Oxygen on CoCrMo alloys was carried out to improve the tribological and corrosion behaviors of these biomedical alloys. In order to optimize the implantation results we were carried experiments at different temperatures. Tribocorrosion tests in bovine serum were used to measure Co, Cr and Mo releasing by using Inductively Coupled Plasma Mass Spectrometry analysis after tests. Also, X-ray Diffraction analysis were employed in order to explain any obtained difference in wear rate and corrosion tests. Wear tests reveals important decreases in rate of more than one order of magnitude for the best treatment.more » Moreover decreases in metal release were found for all the implanted samples, preserving the same corrosion resistance of the unimplanted samples. Finally this paper gathers an analysis, in terms of implantation parameters and achieved properties for industrial implementation of these treatments.« less

  14. Modification of semiconductor materials with the use of plasma produced by low intensity repetitive laser pulses

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wolowski, J.; Rosinski, M.; Badziak, J.

    2008-03-19

    This work reports experiments concerning specific application of laser-produced plasma at IPPLM in Warsaw. A repetitive pulse laser system of parameters: energy up to 0.8 J in a 3.5 ns-pulse, wavelength of 1.06 {mu}m, repetition rate of up to 10 Hz, has been employed in these investigations. The characterisation of laser-produced plasma was performed with the use of 'time-of-flight' ion diagnostics simultaneously with other diagnostic methods. The results of laser-matter interaction were obtained in dependence on laser pulse parameters, illumination geometry and target material. The modified SiO{sub 2} layers and sample surface properties were characterised with the use of differentmore » methods at the Middle-East Technological University in Ankara and at the Warsaw University of technology. The production of the Ge nanocrystallites has been demonstrated for annealed samples prepared in different experimental conditions.« less

  15. Nanoparticle-Enhanced Laser Induced Breakdown Spectroscopy for the noninvasive analysis of transparent samples and gemstones.

    PubMed

    Koral, C; Dell'Aglio, M; Gaudiuso, R; Alrifai, R; Torelli, M; De Giacomo, A

    2018-05-15

    In this paper, Nanoparticle-Enhanced Laser Induced Breakdown Spectroscopy is applied to transparent samples and gemstones with the aim to overcome the laser induced damage on the sample. We propose to deposit a layer of AuNPs on the sample surface by drying a colloidal solution before ablating the sample with a 532 nm pulsed laser beam. This procedure ensures that the most significant fraction of the beam, being in resonance with the AuNP surface plasmon, is mainly absorbed by the NP layer, which in turn results the breakdown to be induced on NPs rather than on the sample itself. The fast explosion of the NPs and the plasma induction allow the ablation and the transfer in the plasma phase of the portion of sample surface where the NPs were placed. The employed AuNPs are prepared in milliQ water without the use of any chemical stabilizers by Pulsed Laser Ablation in Liquids (PLAL), in order to obtain a strict control of composition and impurities, and to limit possible spectral interferences (except from Au emission lines). Therefore with this technique it is possible to obtain, together with the emission signal of Au (coming from atomized NPs), the emission spectrum of the sample, by limiting or avoiding the direct interaction of the laser pulse with the sample itself. This approach is extremely useful for the elemental analysis by laser ablation of high refractive index samples, where the laser pulse on an untreated surface can otherwise penetrate inside the sample, generate breakdown events below the superficial layer, and consequently cause cracks and other damage. The results obtained with NELIBS on high refractive index samples like glasses, tourmaline, aquamarine and ruby are very promising, and demonstrate the potentiality of this approach for precious gemstones analysis. Copyright © 2018 Elsevier B.V. All rights reserved.

  16. Traumatic Hemothorax Blood Contains Elevated Levels of Microparticles that are Prothrombotic but Inhibit Platelet Aggregation.

    PubMed

    Mitchell, Thomas A; Herzig, Maryanne C; Fedyk, Chriselda G; Salhanick, Marc A; Henderson, Aaron T; Parida, Bijaya K; Prat, Nicolas J; Dent, Daniel L; Schwacha, Martin G; Cap, Andrew P

    2017-06-01

    Autotransfusion of shed blood from traumatic hemothorax is an attractive option for resuscitation of trauma patients in austere environments. However, previous analyses revealed that shed hemothorax (HX) blood is defibrinated, thrombocytopenic, and contains elevated levels of D-dimer. Mixing studies with normal pooled plasma demonstrated hypercoagulability, evoking concern for potentiation of acute traumatic coagulopathy. We hypothesized that induction of coagulopathic changes by shed HX blood may be due to increases in cellular microparticles (MP) and that these may also affect recipient platelet function. Shed HX blood was obtained from 17 adult trauma patients under an Institutional Review Board approved prospective observational protocol. Blood samples were collected every hour up to 4 h after thoracostomy tube placement. The corresponding plasma was isolated and frozen for analysis. The effects of shed HX frozen plasma (HFP) and isolated HX microparticles (HMP) on coagulation and platelet function were assessed through mixing studies with platelet-rich plasma at various dilutions followed by analysis with thromboelastometry (ROTEM), platelet aggregometry (Multiplate), enzyme-linked immunosorbent assays, and flow cytometry. Furthermore, HFP was assessed for von Willebrand factor antigen levels and multimer content, and plasma-free hemoglobin. ROTEM analysis demonstrated that diluted HFP and isolated HMP samples decreased clotting time, clotting formation time, and increased α angle, irrespective of sample concentrations, when compared with diluted control plasma. Isolated HMP inhibited platelet aggregation in response to adenosine diphosphate, arachidonic acid, and collagen. HFP contained elevated levels of fibrin-degradation products and tissue factor compared with control fresh frozen plasma samples. MP concentrations in HFP were significantly increased and enriched in events positive for phosphatidylserine, tissue factor, CD235, CD45, CD41a, and CD14. von Willebrand factor (vWF) multimer analysis revealed significant loss of high molecular weight multimers in HFP samples. Plasma-free hemoglobin levels were 8-fold higher in HFP compared with fresh frozen plasma. HFP induces plasma hypercoagulability that is likely related to increased tissue factor and phosphatidylserine expression originating from cell-derived MP. In contrast, platelet dysfunction is induced by HMP, potentially aggravated by depletion of high molecular weight multimers of vWF. Thus, autologous transfusion of shed traumatic hemothorax blood may induce a range of undesirable effects in patients with acute traumatic coagulopathy.

  17. Preliminary Results from the Flight of the Solar Array Module Plasma Interactions Experiment (SAMPIE)

    NASA Technical Reports Server (NTRS)

    Ferguson, Dale C.; Hillard, G. Barry

    1994-01-01

    SAMPIE, the Solar Array Module Plasma Interactions Experiment, flew in the Space Shuttle Columbia payload bay as part of the OAST-2 mission on STS-62, March, 1994. SAMPIE biased samples of solar arrays and space power materials to varying potentials with respect to the surrounding space plasma, and recorded the plasma currents collected and the arcs which occurred, along with a set of plasma diagnostics data. A large set of high quality data was obtained on the behavior of solar arrays and space power materials in the space environment. This paper is the first report on the data SAMPIE telemetered to the ground during the mission. It will be seen that the flight data promise to help determine arcing thresholds, snapover potentials and floating potentials for arrays and spacecraft in LEO.

  18. Microwave digestion preparation and ICP determination of boron in human plasma

    NASA Technical Reports Server (NTRS)

    Ferrando, A. A.; Green, N. R.; Barnes, K. W.; Woodward, B.

    1993-01-01

    A microwave digestion procedure, followed by Inductively Coupled Argon Plasma Spectroscopy, is described for the determination of boron (B) in human plasma. The National Institute of Standards and Technology (NIST) currently does not certify the concentration of B in any substance. The NIST citrus leaves 1572 (CL) Standard Reference Material (SRM) and wheat flour 1567a (WF) were chosen to determine the efficacy of digestion. CL and WF values compare favorably to those obtained from an open-vessel, wet digestion followed by ICP, and by neutron activation and mass spectrometric measurements. Plasma samples were oxidized by doubled-distilled ultrapure HNO3 in 120 mL PFA Teflon vessels. An MDS-81D microwave digestion procedure allows for rapid and relatively precise determination of B in human plasma, while limiting handling hazards and sources of contamination.

  19. Fourth-generation plasma immersion ion implantation and deposition facility for hybrid surface modification layer fabrication.

    PubMed

    Wang, Langping; Huang, Lei; Xie, Zhiwen; Wang, Xiaofeng; Tang, Baoyin

    2008-02-01

    The fourth-generation plasma immersion ion implantation and deposition (PIIID) facility for hybrid and batch treatment was built in our laboratory recently. Comparing with our previous PIIID facilities, several novel designs are utilized. Two multicathode pulsed cathodic arc plasma sources are fixed on the chamber wall symmetrically, which can increase the steady working time from 6 h (the single cathode source in our previous facilities) to about 18 h. Meanwhile, the inner diameter of the pulsed cathodic arc plasma source is increased from the previous 80 to 209 mm, thus, large area metal plasma can be obtained by the source. Instead of the simple sample holder in our previous facility, a complex revolution-rotation sample holder composed of 24 shafts, which can rotate around its axis and adjust its position through revolving around the center axis of the vacuum chamber, is fixed in the center of the vacuum chamber. In addition, one magnetron sputtering source is set on the chamber wall instead of the top cover in the previous facility. Because of the above characteristic, the PIIID hybrid process involving ion implantation, vacuum arc, and magnetron sputtering deposition can be acquired without breaking vacuum. In addition, the PIIID batch treatment of cylinderlike components can be finished by installing these components on the rotating shafts on the sample holder.

  20. Plasma and muscle cortisol measurements as indicators of meat quality and stress in pigs.

    PubMed

    Shaw, F D; Trout, G R; McPhee, C P

    1995-01-01

    Post-slaughter blood samples and muscle samples were collected from pigs slaughtered at the completion of a live-animal performance trial. There were two lines of pigs in which the halothane allele (n) was segregating. The lines were a lean line selected for rapid lean growth and an unselected fat line. There were homozygous normal (NN), homozygous halothane positive (nn) and heterozygous (Nn) genotypes in both lnes. Cortisol was measured in the plasma of the blood samples and in muscle juice obtained by high-speed centrifugation. Meat quality was assessed using pH, colour, fibre-optic probe, drip loss and cure yield measurements. Plasma cortisol concentrations in the fat line were significantly (P < 0·05) greater than thosein the lean line but concentrations did not differ significantly for the three halothane genotypes. Carcasses classified as dark, firm and dry (DFD) had significantly (P < 0·05) greater muscle cortisol concentrations than those classified as normal. Plasma and muscle cortisol concentrations of carcases classified as pale, soft and exudative (PSE) did not differ significantly from those classified as normal. Correlations between muscle cortisol and meat quality attributes were generally highly significant (r = 0·31 to r = 0·51, P < 0·001) There was a highly significant correlation (r = 0·73, P < 0·0001) between plasma and muscle cortisol concentrations.

  1. On the universality of power laws for tokamak plasma predictions

    NASA Astrophysics Data System (ADS)

    Garcia, J.; Cambon, D.; Contributors, JET

    2018-02-01

    Significant deviations from well established power laws for the thermal energy confinement time, obtained from extensive databases analysis as the IPB98(y,2), have been recently reported in dedicated power scans. In order to illuminate the adequacy, validity and universality of power laws as tools for predicting plasma performance, a simplified analysis has been carried out in the framework of a minimal modeling for heat transport which is, however, able to account for the interplay between turbulence and collinear effects with the input power known to play a role in experiments with significant deviations from such power laws. Whereas at low powers, the usual scaling laws are recovered with little influence of other plasma parameters, resulting in a robust power low exponent, at high power it is shown how the exponents obtained are extremely sensitive to the heating deposition, the q-profile or even the sampling or the number of points considered due to highly non-linear behavior of the heat transport. In particular circumstances, even a minimum of the thermal energy confinement time with the input power can be obtained, which means that the approach of the energy confinement time as a power law might be intrinsically invalid. Therefore plasma predictions with a power law approximation with a constant exponent obtained from a regression of a broad range of powers and other plasma parameters which can non-linearly affect and suppress heat transport, can lead to misleading results suggesting that this approach should be taken cautiously and its results continuously compared with modeling which can properly capture the underline physics, as gyrokinetic simulations.

  2. Histamine quantification in human plasma using high resolution accurate mass LC-MS technology.

    PubMed

    Laurichesse, Mathieu; Gicquel, Thomas; Moreau, Caroline; Tribut, Olivier; Tarte, Karin; Morel, Isabelle; Bendavid, Claude; Amé-Thomas, Patricia

    2016-01-01

    Histamine (HA) is a small amine playing an important role in anaphylactic reactions. In order to identify and quantify HA in plasma matrix, different methods have been developed but present several disadvantages. Here, we developed an alternative method using liquid chromatography coupled with an ultra-high resolution and accurate mass instrument, Q Exactive™ (Thermo Fisher) (LCHRMS). The method includes a protein precipitation of plasma samples spiked with HA-d4 as internal standard (IS). LC separation was performed on a C18 Accucore column (100∗2.1mm, 2.6μm) using a mobile phase containing nonafluoropentanoic acid (3nM) and acetonitrile with 0.1% (v/v) formic acid on gradient mode. Separation of analytes was obtained within 10min. Analysis was performed from full scan mode and targeted MS2 mode using a 5ppm mass window. Ion transitions monitored for targeted MS2 mode were 112.0869>95.0607m/z for HA and 116.1120>99.0855m/z for HA-d4. Calibration curves were obtained by adding standard calibration dilution at 1 to 180nM in TrisBSA. Elution of HA and IS occurred at 4.1min. The method was validated over a range of concentrations from 1nM to 100nM. The intra- and inter-run precisions were <15% for quality controls. Human plasma samples from 30 patients were analyzed by LCHRMS, and the results were highly correlated with those obtained using the gold standard radioimmunoassay (RIA) method. Overall, we demonstrate here that LCHRMS is a sensitive method for histamine quantification in biological human plasmas, suitable for routine use in medical laboratories. In addition, LCHRMS is less time-consuming than RIA, avoids the use of radioactivity, and could then be considered as an alternative quantitative method. Copyright © 2015 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  3. Manual versus automated blood sampling: impact of repeated blood sampling on stress parameters and behavior in male NMRI mice

    PubMed Central

    Kalliokoski, Otto; Sørensen, Dorte B; Hau, Jann; Abelson, Klas S P

    2014-01-01

    Facial vein (cheek blood) and caudal vein (tail blood) phlebotomy are two commonly used techniques for obtaining blood samples from laboratory mice, while automated blood sampling through a permanent catheter is a relatively new technique in mice. The present study compared physiological parameters, glucocorticoid dynamics as well as the behavior of mice sampled repeatedly for 24 h by cheek blood, tail blood or automated blood sampling from the carotid artery. Mice subjected to cheek blood sampling lost significantly more body weight, had elevated levels of plasma corticosterone, excreted more fecal corticosterone metabolites, and expressed more anxious behavior than did the mice of the other groups. Plasma corticosterone levels of mice subjected to tail blood sampling were also elevated, although less significantly. Mice subjected to automated blood sampling were less affected with regard to the parameters measured, and expressed less anxious behavior. We conclude that repeated blood sampling by automated blood sampling and from the tail vein is less stressful than cheek blood sampling. The choice between automated blood sampling and tail blood sampling should be based on the study requirements, the resources of the laboratory and skills of the staff. PMID:24958546

  4. Capillary flow-driven microfluidic device with wettability gradient and sedimentation effects for blood plasma separation.

    PubMed

    Maria, M Sneha; Rakesh, P E; Chandra, T S; Sen, A K

    2017-03-03

    We report a capillary flow-driven microfluidic device for blood-plasma separation that comprises a cylindrical well between a pair of bottom and top channels. Exposure of the well to oxygen-plasma creates wettability gradient on its inner surface with its ends hydrophilic and middle portion hydrophobic. Due to capillary action, sample blood self-infuses into bottom channel and rises up the well. Separation of plasma occurs at the hydrophobic patch due to formation of a 'self-built-in filter' and sedimentation. Capillary velocity is predicted using a model and validated using experimental data. Sedimentation of RBCs is explained using modified Steinour's model and correlation between settling velocity and liquid concentration is found. Variation of contact angle on inner surface of the well is characterized and effects of well diameter and height and dilution ratio on plasma separation rate are investigated. With a well of 1.0 mm diameter and 4.0 mm height, 2.0 μl of plasma was obtained (from <10 μl whole blood) in 15 min with a purification efficiency of 99.9%. Detection of glucose was demonstrated with the plasma obtained. Wetting property of channels was maintained by storing in DI water under vacuum and performance of the device was found to be unaffected over three weeks.

  5. Capillary flow-driven microfluidic device with wettability gradient and sedimentation effects for blood plasma separation

    PubMed Central

    Maria, M. Sneha; Rakesh, P. E.; Chandra, T. S.; Sen, A. K.

    2017-01-01

    We report a capillary flow-driven microfluidic device for blood-plasma separation that comprises a cylindrical well between a pair of bottom and top channels. Exposure of the well to oxygen-plasma creates wettability gradient on its inner surface with its ends hydrophilic and middle portion hydrophobic. Due to capillary action, sample blood self-infuses into bottom channel and rises up the well. Separation of plasma occurs at the hydrophobic patch due to formation of a ‘self-built-in filter’ and sedimentation. Capillary velocity is predicted using a model and validated using experimental data. Sedimentation of RBCs is explained using modified Steinour’s model and correlation between settling velocity and liquid concentration is found. Variation of contact angle on inner surface of the well is characterized and effects of well diameter and height and dilution ratio on plasma separation rate are investigated. With a well of 1.0 mm diameter and 4.0 mm height, 2.0 μl of plasma was obtained (from <10 μl whole blood) in 15 min with a purification efficiency of 99.9%. Detection of glucose was demonstrated with the plasma obtained. Wetting property of channels was maintained by storing in DI water under vacuum and performance of the device was found to be unaffected over three weeks. PMID:28256564

  6. Accuracy of recommended sampling and assay methods for the determination of plasma-free and urinary fractionated metanephrines in the diagnosis of pheochromocytoma and paraganglioma: a systematic review.

    PubMed

    Därr, Roland; Kuhn, Matthias; Bode, Christoph; Bornstein, Stefan R; Pacak, Karel; Lenders, Jacques W M; Eisenhofer, Graeme

    2017-06-01

    To determine the accuracy of biochemical tests for the diagnosis of pheochromocytoma and paraganglioma. A search of the PubMed database was conducted for English-language articles published between October 1958 and December 2016 on the biochemical diagnosis of pheochromocytoma and paraganglioma using immunoassay methods or high-performance liquid chromatography with coulometric/electrochemical or tandem mass spectrometric detection for measurement of fractionated metanephrines in 24-h urine collections or plasma-free metanephrines obtained under seated or supine blood sampling conditions. Application of the Standards for Reporting of Diagnostic Studies Accuracy Group criteria yielded 23 suitable articles. Summary receiver operating characteristic analysis revealed sensitivities/specificities of 94/93% and 91/93% for measurement of plasma-free metanephrines and urinary fractionated metanephrines using high-performance liquid chromatography or immunoassay methods, respectively. Partial areas under the curve were 0.947 vs. 0.911. Irrespective of the analytical method, sensitivity was significantly higher for supine compared with seated sampling, 95 vs. 89% (p < 0.02), while specificity was significantly higher for supine sampling compared with 24-h urine, 95 vs. 90% (p < 0.03). Partial areas under the curve were 0.942, 0.913, and 0.932 for supine sampling, seated sampling, and urine. Test accuracy increased linearly from 90 to 93% for 24-h urine at prevalence rates of 0.0-1.0, decreased linearly from 94 to 89% for seated sampling and was constant at 95% for supine conditions. Current tests for the biochemical diagnosis of pheochromocytoma and paraganglioma show excellent diagnostic accuracy. Supine sampling conditions and measurement of plasma-free metanephrines using high-performance liquid chromatography with coulometric/electrochemical or tandem mass spectrometric detection provides the highest accuracy at all prevalence rates.

  7. Heparin removal by ecteola-cellulose pre-treatment enables the use of plasma samples for accurate measurement of anti-Yellow fever virus neutralizing antibodies.

    PubMed

    Campi-Azevedo, Ana Carolina; Peruhype-Magalhães, Vanessa; Coelho-Dos-Reis, Jordana Grazziela; Costa-Pereira, Christiane; Yamamura, Anna Yoshida; Lima, Sheila Maria Barbosa de; Simões, Marisol; Campos, Fernanda Magalhães Freire; de Castro Zacche Tonini, Aline; Lemos, Elenice Moreira; Brum, Ricardo Cristiano; de Noronha, Tatiana Guimarães; Freire, Marcos Silva; Maia, Maria de Lourdes Sousa; Camacho, Luiz Antônio Bastos; Rios, Maria; Chancey, Caren; Romano, Alessandro; Domingues, Carla Magda; Teixeira-Carvalho, Andréa; Martins-Filho, Olindo Assis

    2017-09-01

    Technological innovations in vaccinology have recently contributed to bring about novel insights for the vaccine-induced immune response. While the current protocols that use peripheral blood samples may provide abundant data, a range of distinct components of whole blood samples are required and the different anticoagulant systems employed may impair some properties of the biological sample and interfere with functional assays. Although the interference of heparin in functional assays for viral neutralizing antibodies such as the functional plaque-reduction neutralization test (PRNT), considered the gold-standard method to assess and monitor the protective immunity induced by the Yellow fever virus (YFV) vaccine, has been well characterized, the development of pre-analytical treatments is still required for the establishment of optimized protocols. The present study intended to optimize and evaluate the performance of pre-analytical treatment of heparin-collected blood samples with ecteola-cellulose (ECT) to provide accurate measurement of anti-YFV neutralizing antibodies, by PRNT. The study was designed in three steps, including: I. Problem statement; II. Pre-analytical steps; III. Analytical steps. Data confirmed the interference of heparin on PRNT reactivity in a dose-responsive fashion. Distinct sets of conditions for ECT pre-treatment were tested to optimize the heparin removal. The optimized protocol was pre-validated to determine the effectiveness of heparin plasma:ECT treatment to restore the PRNT titers as compared to serum samples. The validation and comparative performance was carried out by using a large range of serum vs heparin plasma:ECT 1:2 paired samples obtained from unvaccinated and 17DD-YFV primary vaccinated subjects. Altogether, the findings support the use of heparin plasma:ECT samples for accurate measurement of anti-YFV neutralizing antibodies. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Drug monitoring of quinine in men with nonsevere falciparum malaria: study in the Amazon region of Brazil.

    PubMed

    Vieira, J L; Midio, A F

    2001-12-01

    Quinine sulfate has been the drug of choice for the treatment of the ever-increasing number of cases of falciparum malaria in tropical countries. Because of the spectrum of adverse effects produced by the drug in the so-called cinchona syndrome, the variation in its pharmacokinetics during the episodes of falciparum malaria, and the different therapeutic regimens proposed in different countries, the authors monitored quinine plasma concentrations in daily samples of 20 men of the Amazon region in Brazil with nonsevere falciparum malaria who were administered 1 g quinine sulfate every 12 hours for 7 days. Three blood samples were collected from each patient each day: two immediately before administration of the drug (7 am and 7 pm) and one at 11 am. A total of 440 samples were analyzed by a validated method developed in the authors' laboratories using the high-performance liquid chromatographic technique. The overall quinine plasma levels obtained varied from 1.52 to 16.89 microg/mL. From the second day of treatment, overall levels varied from 2.33 to 14.29 microg/mL; the peak concentrations showed values from 4.22 to 16.89 microg/mL, showing the efficacy of the therapeutic regimen used. Adverse effects (signs and symptoms of cinchonism) were observed in all patients. However, no cases of hypoglycemia were detected. Intrapatient comparisons of the obtained quinine plasma concentrations were statistically significant. The quinine dose may be reduced on day 4 of treatment when asexual parasitemia is absent. This way, no resistance to the drug is observed, cinchonism can be minimized, and good adherence to the regimen is obtained.

  9. LC-MS/MS quantification of next-generation biotherapeutics: a case study for an IgE binding Nanobody in cynomolgus monkey plasma.

    PubMed

    Sandra, Koen; Mortier, Kjell; Jorge, Lucie; Perez, Luis C; Sandra, Pat; Priem, Sofie; Poelmans, Sofie; Bouche, Marie-Paule

    2014-05-01

    Nanobodies(®) are therapeutic proteins derived from the smallest functional fragments of heavy chain-only antibodies. The development and validation of an LC-MS/MS-based method for the quantification of an IgE binding Nanobody in cynomolgus monkey plasma is presented. Nanobody quantification was performed making use of a proteotypic tryptic peptide chromatographically enriched prior to LC-MS/MS analysis. The validated LLOQ at 36 ng/ml was measured with an intra- and inter-assay precision and accuracy <20%. The required sensitivity could be obtained based on the selectivity of 2D LC combined with MS/MS. No analyte specific tools for affinity purification were used. Plasma samples originating from a PK/PD study were analyzed and compared with the results obtained with a traditional ligand-binding assay. Excellent correlations between the two techniques were obtained, and similar PK parameters were estimated. A 2D LC-MS/MS method was successfully developed and validated for the quantification of a next generation biotherapeutic.

  10. A new restricted access molecularly imprinted polymer capped with albumin for direct extraction of drugs from biological matrices: the case of chlorpromazine in human plasma.

    PubMed

    de Oliveira Isac Moraes, Gabriel; da Silva, Larissa Meirelles Rodrigues; dos Santos-Neto, Alvaro José; Florenzano, Fábio Herbst; Figueiredo, Eduardo Costa

    2013-09-01

    A new restricted access molecularly imprinted polymer coated with bovine serum albumin (RAMIP-BSA) was developed, characterized, and used for direct analysis of chlorpromazine in human plasma samples. The RAMIP-BSA was synthesized using chlorpromazine, methacrylic acid, and ethylene glycol dimethacrylate as template, functional monomer, and cross-linker, respectively. Glycerol dimethacrylate and hydroxy methyl methacrylate were used to promote a hydrophilic surface (high density of hydroxyl groups). Afterward, the polymer was coated with BSA using glutaraldehyde as cross-linker, resulting in a protein chemical shield around it. The material was able to eliminate ca. 99% of protein when a 44-mg mL(-1) BSA aqueous solution was passed through it. The RAMIP-BSA was packed in a column and used for direct analysis of chlorpromazine in human plasma samples in an online column switching high-performance liquid chromatography system. The analytical calibration curve was prepared in a pool of human plasma samples with chlorpromazine concentrations ranging from 30 to 350 μg L(-1). The correlation coefficient obtained was 0.995 and the limit of quantification was 30 μg L(-1). Intra-day and inter-day precision and accuracy presented variation coefficients and relative errors lower than 15% and within -15 and 15%, respectively. The sample throughput was 3 h(-1) (sample preparation and chromatographic analysis steps) and the same RAMIP-BSA column was efficiently used for about 90 cycles.

  11. Automated determination of polyamines by high-performance liquid chromatography with simple sample preparation.

    PubMed

    van Eijk, H M; Rooyakkers, D R; Deutz, N E

    1996-04-12

    Recently, a new fully endcapped reversed-phase packing material, Inertsil, was introduced, especially suitable for the determination of basic compounds. We used this packing material to separate ophthaldialdehyde (OPA) derivatives of amino acid derivatives completely from the OPA derivatives of spermine (SPM), spermidine (SPD), putrescine (PUT) and cadaverine (CAD). The obtained separation made the commonly used off-line extraction procedure redundant and thus an on-line sample clean-up was introduced. This enabled automation of the procedure resulting in a better reproducibility and a more efficient use of equipment. Furthermore, no studies are required to determine the extraction recovery. The present method has a cycle time of 30 min. A linear response for each polyamine was found up to 250 pmol, with an R2 ranging from 0.9981 (SPM) to 0.9998 (CAD). The limit of detection, calculated at a signal-to-noise ratio of 3, was 0.1 pmol, corresponding to a plasma concentration of 0.1 mumol/l. The coefficient of variation (C.V.) for the peak area was below 3% and for retention times below 0.5% (n = 15). In order to evaluate the applicability of the method, three different types of sample were chromatographed, e.g. urine (obtained from healthy human volunteers), pig plasma and sulfosalicylic acid homogenates of pig intestine biopsies. Tissue homogenates and urine-specimen could easily be quantitated, while plasma concentrations were just above the limit of detection, resulting in a plasma C.V. ranging from 4.8% (SPM) to 13.6% (SPD) and a tissue C.V. ranging from 2.1% (SPM) to 8.5% (CAD), The urinary C.V.s were not determined. In conclusion, the present method provides an easy way to measure polyamine concentrations for most applications.

  12. Cigarette smoke induces methylation of the tumor suppressor gene NISCH

    PubMed Central

    Ostrow, Kimberly Laskie; Michalidi, Christina; Guerrero-Preston, Rafael; Hoque, Mohammad O.; Greenberg, Alissa; Rom, William; Sidransky, David

    2013-01-01

    We have previously identified a putative tumor suppressor gene, NISCH, whose promoter is methylated in lung tumor tissue as well as in plasma obtained from lung cancer patients. NISCH was observed to be more frequently methylated in smoker lung cancer patients than in non-smoker lung cancer patients. Here, we investigated the effect of tobacco smoke exposure on methylation of the NISCH gene. We tested methylation of NISCH after oral keratinocytes were exposed to mainstream and side stream cigarette smoke extract in culture. Methylation of the promoter region of the NISCH gene was also evaluated in plasma obtained from lifetime non-smokers and light smokers (< 20 pack/year), with and without lung tumors, and heavy smokers (20+ pack/year) without disease. Promoter methylation of NISCH was tested by quantitative fluorogenic real-time PCR in all samples. Promoter methylation of NISCH occurred after exposure to mainstream tobacco smoke as well as to side stream tobacco smoke in normal oral keratinocyte cell lines. NISCH methylation was also detected in 68% of high-risk, heavy smokers without detectable tumors. Interestingly, in light smokers, NISCH methylation was present in 69% of patients with lung cancer and absent in those without disease. Our pilot study indicates that tobacco smoke induces methylation changes in the NISCH gene promoter before any detectable cancer. Methylation of the NISCH gene was also found in lung cancer patients’ plasma samples. After confirming these findings in longitudinally collected plasma samples from high-risk populations (such as heavy smokers), examining patients for hypermethylation of the NISCH gene may aid in identifying those who should undergo additional screening for lung cancer. PMID:23503203

  13. Dense plasma formation on the surface of a ferroelectric induced by a driving pulse with a fast fall time

    NASA Astrophysics Data System (ADS)

    Chirko, K.; Krasik, Ya. E.; Sayapin, A.; Felsteiner, J.; Bernshtam, V.

    2003-08-01

    Experimental results are presented of dense plasma formation on the surface of a BaTi-based ferroelectric sample during the fall time of a driving pulse. A negative or positive driving pulse (⩽14 kV), with a slow rise time (˜450 ns) and a fast fall time (40-200 ns), was applied to the rear electrode of the ferroelectric. It was found by different electrical, optical, and spectroscopic diagnostics that this method allows one to form a plasma with a larger density (˜3×1013 cm-3) as compared with that formed by a driving pulse with a fast rise time (⩽4×1012 cm-3). It was shown that the shorter the fall time of the driving pulse the more intense plasma formation occurs. The most uniform and dense plasma formation occurs with a positive driving pulse. In addition, it was found that the shorter the fall time of the positive driving pulse the larger are the current amplitude, the energy, and the divergence of the emitted electrons. The obtained results are discussed in terms of the surface plasma formation and the compensation process of the polarization surface charge of the ferroelectric sample.

  14. Assays for hydrophilic and lipophilic antioxidant capacity (oxygen radical absorbance capacity (ORAC(FL))) of plasma and other biological and food samples.

    PubMed

    Prior, Ronald L; Hoang, Ha; Gu, Liwei; Wu, Xianli; Bacchiocca, Mara; Howard, Luke; Hampsch-Woodill, Maureen; Huang, Dejian; Ou, Boxin; Jacob, Robert

    2003-05-21

    Methods are described for the extraction and analysis of hydrophilic and lipophilic antioxidants, using modifications of the oxygen radical absorbing capacity (ORAC(FL)) procedure. These methods provide, for the first time, the ability to obtain a measure of "total antioxidant capacity" in the protein free plasma, using the same peroxyl radical generator for both lipophilic and hydrophilic antioxidants. Separation of the lipophilic and hydrophilic antioxidant fractions from plasma was accomplished by extracting with hexane after adding water and ethanol to the plasma (hexane/plasma/ethanol/water, 4:1:2:1, v/v). Lipophilic and hydrophilic antioxidants were efficiently partitioned between hexane and aqueous solvents. Conditions for controlling temperature effects and decreasing assay variability using fluorescein as the fluorescent probe were validated in different laboratories. Incubation (37 degrees C for at least 30 min) of the buffer to which AAPH was dissolved was critical in decreasing assay variability. Lipophilic antioxidants represented 33.1 +/- 1.5 and 38.2 +/- 1.9% of the total antioxidant capacity of the protein free plasma in two independent studies of 6 and 10 subjects, respectively. Methods are described for application of the assay techniques to other types of biological and food samples.

  15. A Novel and Rapid Method to Determine Doxycycline in Human Plasma by Liquid Chromatography Tandem Mass Spectrometry

    PubMed Central

    Krishna, A. Chaitanya; Sathiyaraj, M.; Saravanan, R. S.; Chelladurai, R.; Vignesh, R.

    2012-01-01

    A simple, rapid, specific and sensitive liquid chromatography tandem mass spectrometric method has been developed and validated for the determination of doxycycline from the human plasma. Doxycycline is extracted from human plasma by solid phase extraction. Demeclocycline was used as an internal standard. Detection was performed at transitions of 444.800→428.200 for doxycycline and 464.700→448.100 for demeclocycline using mass spectrometry. Chromatographic separation of analyte and internal standard were carried out using a reverse phase C18, column at 0.500 ml/min flow. The assay of doxycycline is linear over the range of 0.055-7.612 μg/ml, with a precision <14.83%, regression coefficient (r2)=0.9961 and the limit of quantification in plasma for doxycycline was 0.055 μg/ml. Mean extraction recovery obtained was 95.55%. Samples are stable at room temperature for 6 h, processed samples were stable at least for 30.20 h and also stable at three freeze-thaw cycles. The method has been used to perform pharmacokinetic and bioequivalence studies in human plasma. PMID:23798780

  16. Plasma concentrations of carbohydrates and sugar alcohols in term newborns after milk feeding.

    PubMed

    Brown, Laura D; Cavalli, Claudio; Harwood, Jeri E F; Casadei, Annachiara; Teng, Cecilia C; Traggiai, Cristina; Serra, Giovanni; Bevilacqua, Giulio; Battaglia, Frederick C

    2008-08-01

    Nonglucose carbohydrates such as galactose, mannose, and inositol play a clinically important role in fetal and neonatal nutrition, though little is known about their metabolism in the neonate. The aim of this study was to determine whether postprandial changes in plasma carbohydrate and sugar alcohol concentrations are affected by clinical variables such as postnatal age (PNA), milk type, feeding volume, or feeding duration in term newborns. Neonates (n = 26) taking intermittent enteral feedings were enrolled. Blood samples were obtained at baseline (immediately before the start of a feeding) and at 2-3 subsequent time points up to 110 min. Postprandial rise was only observed for plasma glucose concentrations [Glu] and plasma galactose concentrations [Gal] and clinical variables did not predict this change. Despite equimolar delivery in milk, the median of [Glu] rise minus [Gal] rise from baseline to second postprandial plasma sample was 674 microM (-38, 3333 microM; p < 0.0001), reflecting efficient hepatic first-pass metabolism of galactose. A significant PNA effect on [Gal] was observed such that for each day PNA there was an 18% decrease in [Gal] (p = 0.03). [Gal] are a function of PNA, suggesting maintenance of a significant ductus venosus shunt in term infants.

  17. Comparative studies of liquid metals for an alternative divertor target in a fusion reactor

    NASA Astrophysics Data System (ADS)

    Tabarés, F. L.; Oyarzabal, E.; Tafalla, D.; Martin-Rojo, A. B.; Pastor, I.; Ochando, M. A.; Medina, F.; Zurro, B.; McCarthy, K. J.; the TJ-II Team

    2017-12-01

    Two liquid metals (LM), Li and LiSn (20:80 at), presently considered as alternative materials for the divertor target of a fusion reactor, have been exposed to the plasma in a capillary porous system (CPS) arrangement in TJ-II. A negligible perturbation of the plasma has been recorded in both cases, even when stellarator plasmas are particularly sensitive to high Z elements due to the tendency to central impurity accumulation. The surface temperature of the LM CPS samples (made of a tungsten mesh impregnated in SnLi or Li) has been measured during the plasma pulse with ms resolution by pyrometry and the thermal balance during heating and cooling has been used to obtain the thermal parameters of the SnLi and Li CPS arrangements. Temperatures as high as 1150 K during TJ-II plasma exposure were observed for the LiSn solid case. Strong changes in the thermal conductivity of the alloy were recorded in the cooling phase at temperatures close to the nominal melting point. The deduced values for the thermal conductivity of the LiSn alloy/CPS sample were significantly lower than those predicted from their individual components.

  18. Quantitation of N-ethyl-3,4-methylenedioxyamphetamine and its major metabolites in human plasma by high-performance liquid chromatography and fluorescence detection.

    PubMed

    Brunnenberg, M; Lindenblatt, H; Gouzoulis-Mayfrank, E; Kovar, K A

    1998-11-20

    A HPLC method has been developed for the analogue of Ecstasy MDE and its major metabolites N-ethyl-4-hydroxy-3-methoxyamphetamine (HME) and 3,4-methylenedioxyamphetamine (MDA) in human plasma. In the course of our investigations we found that the methylenedioxyamphetamines and HME exhibit fluorescence at 322 nm. Therefore the detection could be carried out with a fluorescence (FL) detector. Solid-phase extraction was used for sample preparation and yielded high recovery rates greater than 95%. The limit of quantitation for MDE and its metabolites in the extracts was between 1.5 and 8.9 ng/ml and the method standard deviations were less than 5%. This sensitive, rapid and reliable analytical method has been used successfully in the quantitation of the substances in plasma samples obtained from 14 volunteers in two clinical studies after p.o. administration of 100 to 140 mg MDE*HCI. The maximum plasma concentrations were 235-465 ng/ml (MDE), 67-673 ng/ml (HME) and 7-33 ng/ml (MDA), respectively. Pharmacokinetic parameters have been investigated using the plasma concentration curves.

  19. Vitamin B6 in plasma and cerebrospinal fluid of children.

    PubMed

    Albersen, Monique; Bosma, Marjolein; Jans, Judith J M; Hofstede, Floris C; van Hasselt, Peter M; de Sain-van der Velden, Monique G M; Visser, Gepke; Verhoeven-Duif, Nanda M

    2015-01-01

    Over the past years, the essential role of vitamin B6 in brain development and functioning has been recognized and genetic metabolic disorders resulting in functional vitamin B6 deficiency have been identified. However, data on B6 vitamers in children are scarce. B6 vitamer concentrations in simultaneously sampled plasma and cerebrospinal fluid (CSF) of 70 children with intellectual disability were determined by ultra performance liquid chromatography-tandem mass spectrometry. For ethical reasons, CSF samples could not be obtained from healthy children. The influence of sex, age, epilepsy and treatment with anti-epileptic drugs, were investigated. The B6 vitamer composition of plasma (pyridoxal phosphate (PLP) > pyridoxic acid > pyridoxal (PL)) differed from that of CSF (PL > PLP > pyridoxic acid > pyridoxamine). Strong correlations were found for B6 vitamers in and between plasma and CSF. Treatment with anti-epileptic drugs resulted in decreased concentrations of PL and PLP in CSF. We provide concentrations of all B6 vitamers in plasma and CSF of children with intellectual disability (±epilepsy), which can be used in the investigation of known and novel disorders associated with vitamin B6 metabolism as well as in monitoring of the biochemical effects of treatment with vitamin B6.

  20. Pre-treatment plasma proteomic markers associated with survival in oesophageal cancer

    PubMed Central

    Kelly, P; Paulin, F; Lamont, D; Baker, L; Clearly, S; Exon, D; Thompson, A

    2012-01-01

    Background: The incidence of oesophageal adenocarcinoma is increasing worldwide but survival remains poor. Neoadjuvant chemotherapy can improve survival, but prognostic and predictive biomarkers are required. This study built upon preclinical approaches to identify prognostic plasma proteomic markers in oesophageal cancer. Methods: Plasma samples collected before and during the treatment of oesophageal cancer and non-cancer controls were analysed by surface-enhanced laser desorption/ionisation time-of-flight (SELDI-TOF) mass spectroscopy (MS). Protein peaks were identified by MS in tryptic digests of purified fractions. Associations between peak intensities obtained in the spectra and clinical endpoints (survival, disease-free survival) were tested by univariate (Fisher's exact test) and multivariate analysis (binary logistic regression). Results: Plasma protein peaks were identified that differed significantly (P<0.05, ANOVA) between the oesophageal cancer and control groups at baseline. Three peaks, confirmed as apolipoprotein A-I, serum amyloid A and transthyretin, in baseline (pre-treatment) samples were associated by univariate and multivariate analysis with disease-free survival and overall survival. Conclusion: Plasma proteins can be detected prior to treatment for oesophageal cancer that are associated with outcome and merit testing as prognostic and predictive markers of response to guide chemotherapy in oesophageal cancer. PMID:22294182

  1. Pre-treatment plasma proteomic markers associated with survival in oesophageal cancer.

    PubMed

    Kelly, P; Paulin, F; Lamont, D; Baker, L; Clearly, S; Exon, D; Thompson, A

    2012-02-28

    The incidence of oesophageal adenocarcinoma is increasing worldwide but survival remains poor. Neoadjuvant chemotherapy can improve survival, but prognostic and predictive biomarkers are required. This study built upon preclinical approaches to identify prognostic plasma proteomic markers in oesophageal cancer. Plasma samples collected before and during the treatment of oesophageal cancer and non-cancer controls were analysed by surface-enhanced laser desorption/ionisation time-of-flight (SELDI-TOF) mass spectroscopy (MS). Protein peaks were identified by MS in tryptic digests of purified fractions. Associations between peak intensities obtained in the spectra and clinical endpoints (survival, disease-free survival) were tested by univariate (Fisher's exact test) and multivariate analysis (binary logistic regression). Plasma protein peaks were identified that differed significantly (P<0.05, ANOVA) between the oesophageal cancer and control groups at baseline. Three peaks, confirmed as apolipoprotein A-I, serum amyloid A and transthyretin, in baseline (pre-treatment) samples were associated by univariate and multivariate analysis with disease-free survival and overall survival. Plasma proteins can be detected prior to treatment for oesophageal cancer that are associated with outcome and merit testing as prognostic and predictive markers of response to guide chemotherapy in oesophageal cancer.

  2. Ground-based instruments of the PWING project to investigate dynamics of the inner magnetosphere at subauroral latitudes as a part of the ERG-ground coordinated observation network

    NASA Astrophysics Data System (ADS)

    Shiokawa, Kazuo; Katoh, Yasuo; Hamaguchi, Yoshiyuki; Yamamoto, Yuka; Adachi, Takumi; Ozaki, Mitsunori; Oyama, Shin-Ichiro; Nosé, Masahito; Nagatsuma, Tsutomu; Tanaka, Yoshimasa; Otsuka, Yuichi; Miyoshi, Yoshizumi; Kataoka, Ryuho; Takagi, Yuki; Takeshita, Yuhei; Shinbori, Atsuki; Kurita, Satoshi; Hori, Tomoaki; Nishitani, Nozomu; Shinohara, Iku; Tsuchiya, Fuminori; Obana, Yuki; Suzuki, Shin; Takahashi, Naoko; Seki, Kanako; Kadokura, Akira; Hosokawa, Keisuke; Ogawa, Yasunobu; Connors, Martin; Michael Ruohoniemi, J.; Engebretson, Mark; Turunen, Esa; Ulich, Thomas; Manninen, Jyrki; Raita, Tero; Kero, Antti; Oksanen, Arto; Back, Marko; Kauristie, Kirsti; Mattanen, Jyrki; Baishev, Dmitry; Kurkin, Vladimir; Oinats, Alexey; Pashinin, Alexander; Vasilyev, Roman; Rakhmatulin, Ravil; Bristow, William; Karjala, Marty

    2017-11-01

    The plasmas (electrons and ions) in the inner magnetosphere have wide energy ranges from electron volts to mega-electron volts (MeV). These plasmas rotate around the Earth longitudinally due to the gradient and curvature of the geomagnetic field and by the co-rotation motion with timescales from several tens of hours to less than 10 min. They interact with plasma waves at frequencies of mHz to kHz mainly in the equatorial plane of the magnetosphere, obtain energies up to MeV, and are lost into the ionosphere. In order to provide the global distribution and quantitative evaluation of the dynamical variation of these plasmas and waves in the inner magnetosphere, the PWING project (study of dynamical variation of particles and waves in the inner magnetosphere using ground-based network observations, http://www.isee.nagoya-u.ac.jp/dimr/PWING/) has been carried out since April 2016. This paper describes the stations and instrumentation of the PWING project. We operate all-sky airglow/aurora imagers, 64-Hz sampling induction magnetometers, 40-kHz sampling loop antennas, and 64-Hz sampling riometers at eight stations at subauroral latitudes ( 60° geomagnetic latitude) in the northern hemisphere, as well as 100-Hz sampling EMCCD cameras at three stations. These stations are distributed longitudinally in Canada, Iceland, Finland, Russia, and Alaska to obtain the longitudinal distribution of plasmas and waves in the inner magnetosphere. This PWING longitudinal network has been developed as a part of the ERG (Arase)-ground coordinated observation network. The ERG (Arase) satellite was launched on December 20, 2016, and has been in full operation since March 2017. We will combine these ground network observations with the ERG (Arase) satellite and global modeling studies. These comprehensive datasets will contribute to the investigation of dynamical variation of particles and waves in the inner magnetosphere, which is one of the most important research topics in recent space physics, and the outcome of our research will improve safe and secure use of geospace around the Earth.[Figure not available: see fulltext.

  3. Motion of W and He atoms during formation of W fuzz

    NASA Astrophysics Data System (ADS)

    Doerner, R. P.; Nishijima, D.; Krasheninnikov, S. I.; Schwarz-Selinger, T.; Zach, M.

    2018-06-01

    Measurements are conducted to identify the motion of tungsten and helium atoms during the formation of tungsten fuzz. In a first series of experiments the mobility of helium within the growing fuzz was measured by adding 3He to the different stages of plasma exposure under conditions that promoted tungsten fuzz growth. Ion beam analysis was used to quantify the amount of 3He remaining in the samples following the plasma exposure. The results indicate that the retention of helium in bubbles within tungsten is a dynamic process with direct implantation rather than diffusion into the bubbles, best describing the motion of the helium atoms. In the second experiment, an isotopically enriched layer of tungsten (~92.99% 182W) is deposited on the surface of a bulk tungsten sample with the natural abundance of the isotopes. This sample is then exposed to helium plasma at the conditions necessary to support the formation of tungsten ‘fuzz’. Depth profiles of the concentration of each of the tungsten isotopes are obtained using secondary ion mass spectrometry (SIMS) before and after the plasma exposure. The depth profiles clearly show mixing of tungsten atoms from the bulk sample toward the surface of the fuzz. This supports a physical picture of the dynamic behavior of helium bubbles which, also, causes an enhanced mixing of tungsten atoms.

  4. Limitations of salivary and blood cortisol determinations in pigs.

    PubMed

    Blackshaw, J K; Blackshaw, A W

    1989-01-01

    Blood and saliva samples were taken from groups of pigs maintained in intensive conditions. Multiple samples were taken from two unrestrained pregnant sows fitted with jugular cannulae. Single samples were taken from groups (mixed gilts and entire males; 70-90 kg) which were lightly exercised (7) or restrained (12). The rate of salivary secretion was low and collection of adequate samples took 5 min; in a number of pigs no saliva could be obtained. In order to stimulate salivary secretion, pigs (70-80 kg) were injected with pilocarpine nitrate (25 mg, subcutaneous) which produced a copious flow of saliva persisting for at least 15 min. Resting sows had higher mean levels of cortisol in plasma, ultrafiltrate and saliva than the other groups, which did not differ from each other. Within the pilocarpine group, males had a higher ultrafiltrate level of cortisol than females. In most instances salivary cortisol was significantly greater than ultrafiltrate cortisol. Ultrafiltrate and plasma cortisol were highly correlated (r = 0.883) but this correlation was low in the presence of pilocarpine (r = 0.260). Salivary cortisol was poorly correlated with either plasma (r = 0.167) or ultrafiltrate cortisol (r = 0.278) and the correlation with plasma was even lower following the administration of pilocarpine (r = 0.086). It was concluded that salivary estimates of cortisol in the pig were not usefully correlated with levels of ultrafiltrate (free) cortisol.

  5. Motion of W and He atoms during formation of W fuzz

    DOE PAGES

    Doerner, R. P.; Nishijima, D.; Krasheninnikov, S. I.; ...

    2018-04-11

    Measurements are conducted to identify the motion of tungsten and helium atoms during the formation of tungsten fuzz. In a first series of experiments the mobility of helium within the growing fuzz was measured by adding 3He to the different stages of plasma exposure under conditions that promoted tungsten fuzz growth. Ion beam analysis was used to quantify the amount of 3He remaining in the samples following the plasma exposure. The results indicate that the retention of helium in bubbles within tungsten is a dynamic process with direct implantation rather than diffusion into the bubbles, best describing the motion ofmore » the helium atoms. In the second experiment, an isotopically enriched layer of tungsten (~92.99% 182W) is deposited on the surface of a bulk tungsten sample with the natural abundance of the isotopes. This sample is then exposed to helium plasma at the conditions necessary to support the formation of tungsten 'fuzz'. Depth profiles of the concentration of each of the tungsten isotopes are obtained using secondary ion mass spectrometry (SIMS) before and after the plasma exposure. The depth profiles clearly show mixing of tungsten atoms from the bulk sample toward the surface of the fuzz. Lastly, this supports a physical picture of the dynamic behavior of helium bubbles which, also, causes an enhanced mixing of tungsten atoms.« less

  6. Fully automated, internally controlled quantification of hepatitis B Virus DNA by real-time PCR by use of the MagNA Pure LC and LightCycler instruments.

    PubMed

    Leb, Victoria; Stöcher, Markus; Valentine-Thon, Elizabeth; Hölzl, Gabriele; Kessler, Harald; Stekel, Herbert; Berg, Jörg

    2004-02-01

    We report on the development of a fully automated real-time PCR assay for the quantitative detection of hepatitis B virus (HBV) DNA in plasma with EDTA (EDTA plasma). The MagNA Pure LC instrument was used for automated DNA purification and automated preparation of PCR mixtures. Real-time PCR was performed on the LightCycler instrument. An internal amplification control was devised as a PCR competitor and was introduced into the assay at the stage of DNA purification to permit monitoring for sample adequacy. The detection limit of the assay was found to be 200 HBV DNA copies/ml, with a linear dynamic range of 8 orders of magnitude. When samples from the European Union Quality Control Concerted Action HBV Proficiency Panel 1999 were examined, the results were found to be in acceptable agreement with the HBV DNA concentrations of the panel members. In a clinical laboratory evaluation of 123 EDTA plasma samples, a significant correlation was found with the results obtained by the Roche HBV Monitor test on the Cobas Amplicor analyzer within the dynamic range of that system. In conclusion, the newly developed assay has a markedly reduced hands-on time, permits monitoring for sample adequacy, and is suitable for the quantitative detection of HBV DNA in plasma in a routine clinical laboratory.

  7. Biomaterial compounds and bioactivity of horseshoe crab Carsinoscorpius rotundicauda biomass harvested from the Madura Strait

    NASA Astrophysics Data System (ADS)

    Asih, Eka Nurrahema Ning; Kawaroe, Mujizat; Bengen, Dietriech G.

    2018-03-01

    Carsinoscorpius rotundicauda or horseshoe crab biomass has great potential in pharmaceutical aspects, one of them as an antibacterial substance. Information related to the benefits of Carsinoscorpius rotundicauda biomass such as meat and blood is essential because in fact, this species is considered a pest by fishermen, a low market value and has no legal protection in Indonesia. The purpose of this study was to determine the content of biomaterial compounds of meat and bioactivity of Carsinoscorpius rotundicauda plasma on bacterial inhibition from three different stations harvested from the waters in Madura Strait. The observation of the utilization of the potential from horseshoe crab biomass ie meat and plasma was performed by measuring the content of biomaterial compound in horseshoe crab meat by HPLC method and zone of inhibition test for gram-positive and gram-negative bacteria in horseshoe crab plasma. Analysis of the relationship between the two parameters used the Principal Component Analysis. The highest content of biomaterial compounds of monoterpenoid and zoosterol is found in horseshoe crab from Bangkalan waters, namely monoterpenoid (18.33 ppm) and zoosterol (22.67 ppm), while the smallest compound content obtained in horseshoe crab from Probolinggo waters, namely monoterpenoid (13.67) ppm and zoosterol (17.33 ppm). The bioactivity of Dark Blue Plasma (BDP) and Light Blue Plasma (LBP) samples of horseshoe crab obtained around the Madura Strait has the ability to inhibit gram-positive bacteria higher than gram-negative bacteria. The total average of DBP plasma inhibitory power on Staphylococcus aureus was 10.00 mm and 10.07 mm on Bacillus, while that in LBP sample, Staphylococcus aureus was 9.11 mm and Bacillus was 9.67 mm. The high biomaterial compound content of horseshoe crab is in line with the ability of horseshoe crab plasma to inhibit Bacillus and Staphylococcus aureus.

  8. Enfuvirtide Cerebrospinal Fluid (CSF) Pharmacokinetics and Potential Use in Defining CSF HIV-1 Origin

    PubMed Central

    Price, Richard W; Parham, Robin; Lu, Jing; Wring, Stephen A.; Baker, Brian; Sailstad, Jeff; Hoh, Rebecca; Liegler, Teri; Spudich, Serena; Kuritzkes, Daniel R; Deeks, Steven G

    2009-01-01

    Background Enfuvirtide is a potent inhibitor of systemic HIV-1 replication, but its penetration into the human central nervous system (CNS) has not been analyzed. Here, we define cerebrospinal fluid (CSF) enfuvirtide pharmacokinetics and present a case illustrating the use of enfuvirtide as a probe to trace the origins of CSF HIV-1 quasispecies. Methods Enfuvirtide CSF PK was assessed in 18 CSF and plasma sample pairs from 4 HIV-1-infected subjects. Enfuvirtide levels were measured by liquid chromatography tandem mass spectrometry using known standards and controls that including spiked CSF samples from untreated, HIV-negative subjects. A segment of the gp41-coding region encompassing the heptad repeat (HR)-1 and HR-2 domains was amplified from selected CSF and plasma samples, and independent clones sequenced to assess resistance-associated mutations. Results CSF and plasma samples obtained between 2 and 20 hrs after enfuvirtide injection showed plasma concentrations similar to previous reports (mean 3.687 +/−1.828 µg/ml SD) with prolonged decay. By contrast, enfuvirtide in all CSF samples was below the assay detection limit of 0.025 µg/ml. In one subject, who developed a transient increase in CSF HIV-1 RNA, 7 of 7 CSF and plasma clones had identical enfuvirtide resistance-associated V38A mutation, suggesting that the CSF quasispecies derived from that of blood. Conclusions Enfuvirtide CSF penetration into CSF is negligible, and thus in clinical settings where direct CNS drug exposure is critical, this drug will likely not directly contribute to the local therapeutic effect. Enfuvirtide can be used as a tool to dissect the origin of the CNS virus. PMID:18572749

  9. Low plasma selenium concentration is associated with elevated risk to neoplastic polyps of the colon

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Clark, L.C.; Hixson, L.G.; Sampliner, R.E.

    1991-03-11

    A cross-sectional study was conducted to examine the relationship of selenium (Se) status and polyps incidence in a sequential series of 100 patients undergoing outpatient colonoscopies at the Tucson VA Hospital. Se was measured in plasma samples by electrothermal atomic absorption spectrophotometry with Zeeman background correction using a reduced palladium matrix modified. The activities of the Se-dependent enzyme glutathione peroxidase (SeGSHpx) were measured using H{sub 2}O{sub 2} as substrate in all plasma samples and in colonic mucosal biopsies obtained from some patients. The mean plasma Se concentration of patients without polyps was 134 ng/ml. Mean plasma Se levels of patientsmore » with only diminutive or large polyps were 127 ng/ml and 125 ng/ml; while patients with polyps of both sizes had a mean plasma Se level of 121 ng/ml. Patients with no reported history of cancer, neoplastic polyps or prior colonoscopy, showed an inverse association of plasma Se level and risk of benign colonic neoplasms. The age-adjusted odds ratio for neoplastic polyps was 3.8 for patients with plasma Se levels below vs. above the median value. This association was stronger for patients under 68 yrs of age than for older patients. Activities of SeGSHpx in plasma or colonic mucosa were not related to plasma Se level; however, smokers showed greater SeGSHpx activities than non-smokers. This study is the first to detect an association of Se status and risk to neoplastic polyps of the colon.« less

  10. Pharmacokinetics of long-acting nalbuphine decanoate after intramuscular administration to Hispaniolan Amazon parrots (Amazona ventralis).

    PubMed

    Sanchez-Migallon Guzman, David; KuKanich, Butch; Heath, Timothy D; Krugner-Higby, Lisa A; Barker, Steven A; Brown, Carolyn S; Paul-Murphy, Joanne R

    2013-02-01

    To evaluate the pharmacokinetics of nalbuphine decanoate after IM administration to Hispaniolan Amazon parrots (Amazona ventralis). 9 healthy adult Hispaniolan Amazon parrots of unknown sex. Nalbuphine decanoate (37.5 mg/kg) was administered IM to all birds. Plasma samples were obtained from blood collected before (time 0) and 0.25, 1, 2, 3, 6, 12, 24, 48, and 96 hours after drug administration. Plasma samples were used for measurement of nalbuphine concentrations via liquid chromatography-tandem mass spectrometry. Pharmacokinetic parameters were estimated with computer software. Plasma concentrations of nalbuphine increased rapidly after IM administration, with a mean concentration of 46.1 ng/mL at 0.25 hours after administration. Plasma concentrations of nalbuphine remained > 20 ng/mL for at least 24 hours in all birds. The maximum plasma concentration was 109.4 ng/mL at 2.15 hours. The mean terminal half-life was 20.4 hours. In Hispaniolan Amazon parrots, plasma concentrations of nalbuphine were prolonged after IM administration of nalbuphine decanoate, compared with previously reported results after administration of nalbuphine hydrochloride. Plasma concentrations that could be associated with antinociception were maintained for 24 hours after IM administration of 37.5 mg of nalbuphine decanoate/kg. Safety and analgesic efficacy of nalbuphine treatments in this species require further investigation to determine the potential for clinical use in pain management in psittacine species.

  11. Meat juice: An alternative matrix for assessing animal health by measuring acute phase proteins. Correlations of pig-MAP and haptoglobin concentrations in pig meat juice and plasma.

    PubMed

    Piñeiro, M; Gymnich, S; Knura, S; Piñeiro, C; Petersen, B

    2009-10-01

    Quantification of acute phase proteins (APPs) in blood can be used for monitoring animal health and welfare on farms, and could be also of interest for the detection of diseased animals during the meat inspection process. However serum or plasma is not always available for end-point analysis at slaughter. Meat juice might provide an adequate, alternative matrix that can be easily obtained for post-mortem analysis at abattoirs. The concentrations of pig Major Acute phase Protein (pig-MAP) and haptoglobin, two of the main APPs in pigs, were determined in approximately 300 paired samples of plasma and meat juice from the diaphragm (pars costalis), obtained after freezing and thawing the muscle. APPs concentrations in meat juice were closely correlated to those in plasma (r=0.695 for haptoglobin, r=0.858 for pig-MAP, p<0.001). These results open new possibilities for the assessment of animal health in pig production, with implications for food safety and meat quality.

  12. Measurement of Salivary Cortisone to Assess the Adequacy of Hydrocortisone Replacement.

    PubMed

    Raff, Hershel

    2016-04-01

    This Commentary discusses the study of Debono et al (19) and focuses on the potential use of multiple salivary cortisone measurements to evaluate the adequacy of hydrocortisone replacement therapy. Salivary cortisone, typically measured using liquid chromatography-tandem mass spectrometry, accurately reflects plasma free cortisol because of the expression of 11-β -hydroxysteroid dehydrogenase in the salivary gland. Debono et al showed that multiple, sequential salivary cortisone measurements obtained over a 12-hour period correlated with plasma free cortisol in subjects receiving intravenous or oral hydrocortisone (authentic cortisol). Hopefully, these studies will lead to a simplified protocol with fewer samples for the measurement of salivary cortisone that can reliably assess the adequacy of hydrocortisone replacement in patients with adrenal insufficiency. This protocol has to be cost-effective and be feasible to obtain timed salivary samples accurately at home. It would be a significant advance to be able to monitor hydrocortisone replacement therapy with as few as one or two salivary cortisone measurements.

  13. Kinetic disposition of lorazepam with focus on the glucuronidation capacity, transplacental transfer in parturients and racemization in biological samples.

    PubMed

    Papini, Olga; da Cunha, Sergio Pereira; da Silva Mathes, Angelo do Carmo; Bertucci, Carlo; Moisés, Elaine Christine Dantas; de Barros Duarte, Luciana; de Carvalho Cavalli, Ricardo; Lanchote, Vera Lucia

    2006-02-13

    The present study investigates the kinetic disposition with focus on the racemization, glucuronidation capacity and the transplacental transfer of lorazepam in term parturients during labor. The study was conducted on 10 healthy parturients aged 18-37 years with a gestational age of 36-40.1 weeks, treated with a single oral dose of 2 mg racemic lorazepam 2-9 h before delivery. Maternal venous blood and urine samples were obtained over a 0-48 h interval and the umbilical cord sample was obtained immediately after clamping. Lorazepam enantiomers were determined in plasma and urine samples by LC-MS/MS using a Chiralcel OD-R column. In vitro racemization of lorazepam required the calculation of the pharmacokinetic parameters as isomeric mixtures. The data were fitted to two-compartment model and the pharmacokinetic parameters are reported as means (95% CI): t(1/2a) 3.2h (2.6-3.7 h), K(a) 0.23 h(-1) (0.19-0.28 h(-1)), t(1/2) 10.4h (9.4-11.3h), beta 0.068 h(-1) (0.061-0.075h(-1)), AUC(0-infinity) 175.3(ngh)/ml (145.7-204.8(ngh)/ml), Cl/F 2.6 ml/(minkg) (2.3-2.9 ml/(minkg)), Vd/F178.8l (146.5-211.1l), Fel 0.3% (0.1-0.5%), and Cl(R) 0.010 ml/(minkg) (0.005-0.015 ml/(minkg)). Placental transfer of lorazepam evaluated as the ratio of vein umbilical/maternal vein plasma concentrations, obtained as an isomeric mixture, was 0.73 (0.52-0.94). Pregnancy changes the pharmacokinetics of lorazepam, with an increase in the apparent distribution volume, an increase in apparent oral clearance, and a reduction of elimination half-life. The increase in oral clearance may indicate an increase in glucuronidation capacity, with a possible reduction in the plasma concentrations of drugs depending on glucuronidation capacity as the major metabolic pathway.

  14. Profiling of tryptophan-related plasma indoles in patients with carcinoid tumors by automated, on-line, solid-phase extraction and HPLC with fluorescence detection.

    PubMed

    Kema, I P; Meijer, W G; Meiborg, G; Ooms, B; Willemse, P H; de Vries, E G

    2001-10-01

    Profiling of the plasma indoles tryptophan, 5-hydroxytryptophan (5-HTP), serotonin, and 5-hydroxyindoleacetic acid (5-HIAA) is useful in the diagnosis and follow-up of patients with carcinoid tumors. We describe an automated method for the profiling of these indoles in protein-containing matrices as well as the plasma indole concentrations in healthy controls and patients with carcinoid tumors. Plasma, cerebrospinal fluid, and tissue homogenates were prepurified by automated on-line solid-phase extraction (SPE) in Hysphere Resin SH SPE cartridges containing strong hydrophobic polystyrene resin. Analytes were eluted from the SPE cartridge by column switching. Subsequent separation and detection were performed by reversed-phase HPLC combined with fluorometric detection in a total cycle time of 20 min. We obtained samples from 14 healthy controls and 17 patients with metastasized midgut carcinoid tumors for plasma indole analysis. In the patient group, urinary excretion of 5-HIAA and serotonin was compared with concentrations of plasma indoles. Within- and between-series CVs for indoles in platelet-rich plasma were 0.6-6.2% and 3.7-12%, respectively. Results for platelet-rich plasma serotonin compared favorably with those obtained by single-component analysis. Plasma 5-HIAA, but not 5-HTP was detectable in 8 of 17 patients with carcinoid tumors. In the patient group, platelet-rich plasma total tryptophan correlated negatively with platelet-rich plasma serotonin (P = 0.021; r = -0.56), urinary 5-HIAA (P = 0.003; r = -0.68), and urinary serotonin (P <0.0001; r = -0.80). The present chromatographic approach reduces analytical variation and time needed for analysis and gives more detailed information about metabolic deviations in indole metabolism than do manual, single-component analyses.

  15. Plasma-enhanced synthesis of green flame retardant cellulosic materials

    NASA Astrophysics Data System (ADS)

    Totolin, Vladimir

    The natural fiber-containing fabrics and composites are more environmentally friendly, and are used in transportation (automobiles, aerospace), military applications, construction industries (ceiling paneling, partition boards), consumer products, etc. Therefore, the flammability characteristics of the composites based on polymers and natural fibers play an important role. This dissertation presents the development of plasma assisted - green flame retardant coatings for cellulosic substrates. The overall objective of this work was to generate durable flame retardant treatment on cellulosic materials. In the first approach sodium silicate layers were pre-deposited onto clean cotton substrates and cross linked using low pressure, non-equilibrium oxygen plasma. A statistical design of experiments was used to optimize the plasma parameters. The modified cotton samples were tested for flammability using an automatic 45° angle flammability test chamber. Aging tests were conducted to evaluate the coating resistance during the accelerated laundry technique. The samples revealed a high flame retardant behavior and good thermal stability proved by thermo-gravimetric analysis. In the second approach flame retardant cellulosic materials have been produced using a silicon dioxide (SiO2) network coating. SiO 2 network armor was prepared through hydrolysis and condensation of the precursor tetraethyl orthosilicate (TEOS), prior coating the substrates, and was cross linked on the surface of the substrates using atmospheric pressure plasma (APP) technique. Due to protection effects of the SiO2 network armor, the cellulosic based fibers exhibit enhanced thermal properties and improved flame retardancy. In the third approach, the TEOS/APP treatments were extended to linen fabrics. The thermal analysis showed a higher char content and a strong endothermic process of the treated samples compared with control ones, indicating a good thermal stability. Also, the surface analysis proved the existence of the silica-based coatings on all treated cellulosic substrates after intense ultrasound washes. The results obtained in this work allow us to conclude that silica-based coatings used in conjunction with plasma processes have high potential to obtain green flame retardant cellulosic materials with potential applications in the development of upholstered furniture, clothing and military applications.

  16. CoPt/TiN films nanopatterned by RF plasma etching towards dot-patterned magnetic media

    NASA Astrophysics Data System (ADS)

    Szívós, János; Pothorszky, Szilárd; Soltys, Jan; Serényi, Miklós; An, Hongyu; Gao, Tenghua; Deák, András; Shi, Ji; Sáfrán, György

    2018-03-01

    CoPt thin films as possible candidates for Bit Patterned magnetic Media (BPM) were prepared and investigated by electron microscopy techniques and magnetic measurements. The structure and morphology of the Direct Current (DC) sputtered films with N incorporation were revealed in both as-prepared and annealed state. Nanopatterning of the samples was carried out by means of Radio Frequency (RF) plasma etching through a Langmuir-Blodgett film of silica nanospheres that is a fast and high throughput technique. As a result, the samples with hexagonally arranged 100 nm size separated dots of fct-phase CoPt were obtained. The influence of the order of nanopatterning and anneling on the nanostructure formation was revealed. The magnetic properties of the nanopatterned fct CoPt films were investigated by Vibrating Sample Magnetometer (VSM) and Magnetic Force Microscopy (MFM). The results show that CoPt thin film nanopatterned by means of the RF plasma etching technique is promising candidate to a possible realization of BPM. Furthermore, this technique is versatile and suitable for scaling up to technological and industrial applications.

  17. Dielectric barrier discharge micro-plasma emission spectrometry for the detection of acetone in exhaled breath.

    PubMed

    Yang, Ting; Gao, Dong-Xue; Yu, Yong-Liang; Chen, Ming-Li; Wang, Jian-Hua

    2016-01-01

    Acetone is a predominant volatile organic compound (VOC) in the exhaled breath and a promising biomarker for diabetes and ketoacidosis. A non-thermal micro-plasma generated in a planar dielectric barrier discharge (DBD) is used as a radiation source for the excitation of gaseous acetone followed by its quantification with optical emission spectrometry (OES). Gaseous acetone can be directly sampled, while liquid acetone is evaporated by heated tungsten coil and then introduced into the DBD micro-plasma by a helium carrier flow for performing optical emission and detection at a 519 nm emission line. In the present study, the exhaled breath is collected and transferred into aqueous medium for sampling. With a sampling volume of 7 μL in a micro-drop, a linear range of 40-1600 mg L(-1) is obtained along with a detection limit of 44 ng and a precision of 5.7% RSD. The present system is successfully applied to the determination of breath acetone for both diabetic patients and healthy volunteers. Copyright © 2015 Elsevier B.V. All rights reserved.

  18. Plasma-free homovanillic acid: within- and across-day stability in children and adults with Tourette's syndrome.

    PubMed

    Riddle, M A; Leckman, J F; Anderson, G M; Ort, S I; Hardin, M T; Stevenson, J; Cohen, D J

    1987-06-01

    Within- and across-day stability of plasma-free homovanillic acid (pHVA) was assessed in children and adults with Tourette's syndrome. A diurnal fall in pHVA was observed in 13 of 15 subjects. There was a small but significant (p less than .0001) decrease (8%) in mean morning pHVA levels obtained just 20 minutes apart (8:30 A.M. and 8:50 A.M.). A substantial and significant (p less than .001) mean decrease in pHVA (25%) was observed when samples obtained between 8:00 and 8:30 A.M. were compared with samples obtained at 12:00 noon. Changes in pHVA levels observed during the afternoon (between 12:00 noon and 4:00 P.M.) were small, nondirectional, and nonsignificant. Repeated measurement of morning pHVA in the same individual after 24 or more hours revealed marked increases or decreases in many individuals, suggesting that morning pHVA is not a stable measure. The results of this and previous studies suggest that pHVA obtained at 12:00 noon or later in the day may be a more reliable measure of centrally produced HVA. Further studies are needed regarding the stability of pHVA over time.

  19. Measurement of cardiac troponin I utilizing a point of care analyzer in healthy alpacas.

    PubMed

    Blass, Keith A; Kraus, Marc S; Rishniw, Mark; Mann, Sabine; Mitchell, Lisa M; Divers, Thomas J

    2011-12-01

    Myocardial disease in camelids is poorly characterized. Nutritional (selenium deficiency) and toxic (ionophore toxicity) myocardial disease have been reported in camelids. Diagnosis and management of these and other myocardial diseases might be enhanced by evaluating cardiac troponin I (cTnI) concentrations. No information about cTnI reference intervals in camelids is currently available. (A) To determine cTnI concentrations obtained using a point of care i-STAT(®)1 analyzer (Heska Corporation) in healthy alpacas; (B) to compare alpaca cTnI concentrations between heparinized whole blood and plasma samples and between 2 different storage conditions (4 °C for 24 h or -80 °C for 30 days); (C) to examine assay reproducibility using the i-STAT(®)1. 23 healthy alpacas were evaluated. Blood and plasma samples were analyzed by the i-STAT(®)1 within 1 h of collection. Aliquots of plasma were stored at either 4 °C for 24 h or -80 °C for 30 days, and then analyzed. Assay reproducibility was determined by comparing 2 plasma or whole blood cTnI concentrations measured on the same sample over a 10 min period. Analyzer-specific plasma cTnI concentrations in clinically normal alpacas had a median of <0.02 ng/mL (range: <0.02 ng/mL to 0.07 ng/mL). Plasma and whole blood concentrations showed good agreement. Storage did not affect cTnI concentrations (p > 0.75). Plasma cTnI concentrations had coefficient of repeatability of 0.02 ng/mL. The i-STAT(®)1 can measure cTnI in alpacas on both plasma and whole blood and provides similar values for both samples. Storage at 4 °C for 24 h or -80 °C for 30 days does not affect estimates of plasma cTnI. Evaluation of cTnI might be of value in assessing cardiac disease in this species. Copyright © 2011 Elsevier B.V. All rights reserved.

  20. Plasma concentrations of lipids and lipoproteins in newborn kids and female Baladi goats during late pregnancy and onset of lactation.

    PubMed

    Hussein, S A; Azab, M E

    1998-01-01

    Concentrations of blood lipids and some lipoproteins were investigated in normal female Baladi goats during late pregnancy, parturition and onset of lactation as well as in their newborn kids during the first two weeks of life. A total number of 60 herparinized blood samples was collected from does at 4, 3, 2 and 1 weeks pre-partum, day of parturition and at 1, 2, 3 and 4 weeks postpartum. In addition, blood samples were also collected from their newborn kids during the first two weeks of life (day of birth, 1 and 2 weeks of age). Plasma was separated and analyzed for concentration of total lipid, total cholesterol, triacylglycerols, phospholipids, non esterified fatty acids (NEFA) and some lipoproteins as high density lipoprotein cholesterol (HDL-C) and low density lipoprotein cholesterol (LDL-C). The obtained results revealed that there was a significant decrease in plasma level of total lipids at one week after parturition. Plasma level of triaclyglycerols was significantly higher at 4, 3 and 2 weeks before parturition. This increase became very highly significant at one week before parturition. Meanwhile, plasma phospholipid concentrations showed a significant decrease at 3 weeks before parturition, followed by an significant increase at 2 and 3 weeks after parturition and highly significant increase at 4 weeks after parturition. The concentration of plasma NEFA showed a significant increase at 4 weeks before parturition followed by a very highly significant increase at 2 and 1 week before parturition. On the other hand plasma NEFA was non detected at 2, 3 and 4 weeks post-partum when compared with the value reported at day of parturition. Regarding plasma lipoprotein concentrations the obtained results showed that there was a significant increase in plasma HDL-C level at 2 and 3 weeks after parturition, followed by a very highly significant decrease at the fourth week post-partum. However, plasma LDL-C level showed a significant decrease at 3, 2 and 1 weeks before parturition, followed by a further highly significant decrease at 1 and 2 weeks post-partum. In newborn kids plasma concentrations of total lipids, total cholesterol, phospholipids, HDL-C and LDL-C were very markedly increased at 1 and 2 weeks of age. However, plasma triacylglycerol concentrations showed a highly significant decrease at 1 and 2 weeks of age. The concentration of plasma NEFA showed a very highly significant decrease at 2 weeks of age, whereas, at one week of age plasma NEFA were not detected in comparison with first day of life.

  1. Opacity Measurement and Theoretical Investigation of Hot Silicon Plasma

    NASA Astrophysics Data System (ADS)

    Xiong, Gang; Yang, Jiamin; Zhang, Jiyan; Hu, Zhimin; Zhao, Yang; Qing, Bo; Yang, Guohong; Wei, Minxi; Yi, Rongqing; Song, Tianming; Li, Hang; Yuan, Zheng; Lv, Min; Meng, Xujun; Xu, Yan; Wu, Zeqing; Yan, Jun

    2016-01-01

    We report on opacity measurements of a silicon (Si) plasma at a temperature of (72 ± 5) eV and a density of (6.0 ± 1.2) mg cm-3 in the photon energy range of 1790-1880 eV. A 23 μg cm-2 Si foil tamped by 50 μg cm-2 CH layers on each side was heated to a hot-dense plasma state by X-ray radiation emitted from a D-shaped gold cavity that was irradiated by intense lasers. Absorption lines of 1s - 2p transitions of Si xiii to Si ix ions have been measured using point-projection spectroscopy. The transmission spectrum of the silicon plasma was determined by comparing the light passing through the plasma to the light from the same shot passing by the plasma. The density of the Si plasma was determined experimentally by side-on radiography and the temperature was estimated from the radiation flux data. Radiative hydrodynamic simulations were performed to obtain the temporal evolutions of the density and temperature of the Si plasma. The experimentally obtained transmission spectra of the Si sample plasma have been reproduced using a detailed term account model with the local thermodynamic equilibrium approximation. The energy levels, oscillator strengths and photoionization cross-sections used in the calculation were generated by the flexible atomic code. The experimental transmission spectrum was compared with the theoretical calculation and good agreement was found. The present experimental spectrum and theoretical calculation were also compared with the new opacities available in the Los Alamos OPLIB database.

  2. Ultrasonic technique for measuring porosity of plasma-sprayed alumina coatings

    NASA Astrophysics Data System (ADS)

    Parthasarathi, S.; Tittmann, B. R.; Onesto, E. J.

    1997-12-01

    Porosity is an important factor in plasma-sprayed coatings, especially ceramic coatings. Excessive poros-ity can adversely affect the performance of the coated component in various ways. An ultrasonic nonde-structive measurement technique has been developed to measure porosity in plasma-sprayed alumina coatings. The technique is generic and can be extended to other ceramic coating systems. To test the tech-nique, freestanding alumina coatings with varying levels of porosity were fabricated via plasma spray. Samples with varying porosity, obtained through innovative fabrication techniques, were used to gener-ate a calibration curve. The ultrasonic velocity in the low-frequency range was found to be dependent on the density of freestanding coatings (measured via Archimedian techniques). This dependence is the basis of the development of a technique to measure the density of coatings.

  3. Characterization of a low pressure supersonic plasma jet

    NASA Astrophysics Data System (ADS)

    Caldirola, S.; Barni, R.; Riccardi, C.

    2014-11-01

    Plasma assisted supersonic jet deposition (PA-SJD) is a technique which combines a inductively coupled plasma (ICP) with a supersonic jet for the fabrication of thin films having a desired morphology. A reactive argon-oxygen plasma is employed to dissociate an organic precursor (titanium tetra-isopropoxide for TiO2 thin films) in a first vacuum chamber which is connected through a nozzle to a lower pressure chamber. The pressure difference produces a supersonic jet, seeded with nanoparticles. Along the jet the nucleation and aggregation of nanoparticles can be controlled to obtain nanostructured depositions. We report here the results of an analysis performed with a quadrupole mass spectrometer (QMS) which was used to sample neutrals and ions from the jet at different positions along the centerline of the supersonic expansion.

  4. Novel micro-extraction by packed sorbent procedure for the liquid chromatographic analysis of antiepileptic drugs in human plasma and urine.

    PubMed

    Rani, Susheela; Malik, Ashok K; Singh, Baldev

    2012-02-01

    A method for the simultaneous determination of the antiepileptic drugs, phenobarbital (PHB), phenytoin (PTN), carbamazepine (CBZ), primidone (PRM) and oxcarbazepine (OXC) in human plasma and urine samples by using micro-extraction in a packed syringe as the sample preparation method connected with LC/UV (MEPS/LC/UV) is described. Micro-extraction in a packed syringe (MEPS) is a new miniaturized, solid-phase extraction technique that can be connected online to gas or liquid chromatography without any modifications. In MEPS approximately 1 mg of the solid packing material is inserted into a syringe (100-250 μL) as a plug. Sample preparation takes place on the packed bed. The bed can be coated to provide selective and suitable sampling conditions. The new method is very promising, easy to use, fully automated, inexpensive and quick. The standard curves were obtained within the concentration range 1-500 ng/mL in both plasma and urine samples. The results showed high correlation coefficients (R(2) >0.988) for all of the analytes within the calibration range. The extraction recovery was found to be between 88.56 and 99.38%. The limit of quantification was found to be between 0.132 and 1.956 ng/mL. The precision (RSD) values of quality control samples (QC) had a maximum deviation of 4.9%. A comparison of the detection limits with similar methods indicates high sensitivity of the present method. The method is applied for the analysis of these drugs in real urine and plasma samples of epileptic patients. Copyright © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  5. High Degree of Interlaboratory Reproducibility of Human Immunodeficiency Virus Type 1 Protease and Reverse Transcriptase Sequencing of Plasma Samples from Heavily Treated Patients

    PubMed Central

    Shafer, Robert W.; Hertogs, Kurt; Zolopa, Andrew R.; Warford, Ann; Bloor, Stuart; Betts, Bradley J.; Merigan, Thomas C.; Harrigan, Richard; Larder, Brendon A.

    2001-01-01

    We assessed the reproducibility of human immunodeficiency virus type 1 (HIV-1) reverse transcriptase (RT) and protease sequencing using cryopreserved plasma aliquots obtained from 46 heavily treated HIV-1-infected individuals in two laboratories using dideoxynucleotide sequencing. The rates of complete sequence concordance between the two laboratories were 99.1% for the protease sequence and 99.0% for the RT sequence. Approximately 90% of the discordances were partial, defined as one laboratory detecting a mixture and the second laboratory detecting only one of the mixture's components. Only 0.1% of the nucleotides were completely discordant between the two laboratories, and these were significantly more likely to occur in plasma samples with lower plasma HIV-1 RNA levels. Nucleotide mixtures were detected at approximately 1% of the nucleotide positions, and in every case in which one laboratory detected a mixture, the second laboratory either detected the same mixture or detected one of the mixture's components. The high rate of concordance in detecting mixtures and the fact that most discordances between the two laboratories were partial suggest that most discordances were caused by variation in sampling of the HIV-1 quasispecies by PCR rather than by technical errors in the sequencing process itself. PMID:11283081

  6. Simultaneous quantitation of sphingoid bases by UPLC-ESI-MS/MS with identical 13C-encoded internal standards.

    PubMed

    Mirzaian, M; Wisse, P; Ferraz, M J; Marques, A R A; Gaspar, P; Oussoren, S V; Kytidou, K; Codée, J D C; van der Marel, G; Overkleeft, H S; Aerts, J M

    2017-03-01

    Free sphingoid bases (lysosphingolipids) of primary storage sphingolipids are increased in tissues and plasma of several sphingolipidoses. As shown earlier by us, sphingoid bases can be accurately quantified using UPLC-ESI-MS/MS, particularly in combination with identical 13 C-encoded internal standards. The feasibility of simultaneous quantitation of sphingoid bases in plasma specimens spiked with a mixture of such standards is here described. The sensitivity and linearity of detection is excellent for all examined sphingoid bases (sphingosine, sphinganine, hexosyl-sphingosine (glucosylsphingosine), hexosyl 2 -sphingosine (lactosylsphingosine), hexosyl 3 -sphingosine (globotriaosylsphingosine), phosphorylcholine-sphingosine) in the relevant concentration range and the measurements show very acceptable intra- and inter-assay variation (<10% average). Plasma samples of a series of male and female Gaucher Disease and Fabry Disease patients were analyzed with the multiplex assay. The obtained data compare well to those earlier determined for plasma globotriaosylsphingosine and glucosylsphingosine in GD and FD patients. The same approach can be also applied to measure sphingolipids in the same sample. Following extraction of sphingolipids from the same sample these can be converted to sphingoid bases by microwave exposure and subsequently quantified using 13 C-encoded internal standards. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. Silicon Isotopic Measurements in Desolvated Samples by MC-ICP-MS

    NASA Astrophysics Data System (ADS)

    Cardinal, D.; Alleman, L.; Ziegler, K.; de Jong, J.; Andre, L.

    2002-12-01

    Silicon, the most ubiquitous rock-forming element presents also a key role in biological processes. In particular, its biogeochemical cycle constitutes one of the most challenging issues in recent years due to its close relationship with the carbon cycle in marine environments (Tréguer et al., 1995; Ragueneau et al., 2000). The most recent silicon isotopic investigations on various natural samples have highlighted the great potential of this (palaeo)-proxy for oceanographers (De La Rocha et al., 1997, 1998). Better understanding the silicon isotope fractionation due to various biogeochemical processes can be achieved by facilitating its measurements through MC-ICPMS technique (De La Rocha et al., 2002; Alleman et al., 2002). In this regard we have developed an original method to analyze silicon isotopes under dry plasma conditions. We demonstrate that coupling a Nu Plasma MC-ICP-MS with a Cetac Aridus desolvator allows the rapid acquisition of natural silicon isotope abundances with high sensitivity and accuracy. To adequately correct for the mass fractionation occurring at the interface between the plasma source and the mass spectrometer line, we combine external normalization using Mg as a dopant with standard-sample bracketing using NBS-28 as the reference. With the desolvating nebulization system, the measurement of 28Si and 29Si isotopes is not hampered by significant interferences. δ29Si values are obtained with an accuracy and repeatability better than 0.1 \\permil. The accuracy has been successfully calibrated against the laser fluorination line technique (De La Rocha et al., 1996; Alleman et al., 2002). We could demonstrate that the isotopic fractionation that might occur in the plasma or the desolvator was adequately corrected by combining Mg isotopes and the sample-standard bracketing procedure. Moreover, the preservation of the Si isotopic signatures of the samples is validated by the different chemical sample treatments required by these two techniques. This method presents clear advantages compared to the wet plasma technique described by De La Rocha et al. (2002), also using a Nu Plasma MC-ICP-MS, as being much more sensitive and less time consuming. We report here single δ29Si data obtained within one hour and requiring less than 3μg Si per sample. Preliminary results over a large range of natural samples including diatomite, large diatoms, sponge spicules, phytoliths and water from lakes and seawater will also be presented and briefly discussed. Alleman et al., 2002, Geochim. Cosmochim. Acta, 66:15A, A14, Abstract.\\De La Rocha et al., 1996, Anal. Chem., 68, 3746-3750.\\De La Rocha et al., 1997, Geochim. Cosmochim. Acta, 61, 5051-5056.\\De La Rocha et al., 1998, Nature, 395, 680-683.\\De La Rocha, 2002, Geochem., Geophys., Geosyst., 3(8), 10.1029/2002GC00310.\\Ragueneau et al., 2000, Global Planet. Change, 26, 317-365.\\Tréguer et al., 1995, Science, 268, 375-379.

  8. A rapid ultrasound-assisted dispersive liquid-liquid microextraction followed by ultra-performance liquid chromatography for the simultaneous determination of seven benzodiazepines in human plasma samples.

    PubMed

    Fernández, Purificación; González, Cristina; Pena, M Teresa; Carro, Antonia M; Lorenzo, Rosa A

    2013-03-12

    A simple and efficient ultrasound-assisted dispersive liquid-liquid microextraction (UA-DLLME) method has been developed for the determination of seven benzodiazepines (alprazolam, bromazepam, clonazepam, diazepam, lorazepam, lormetazepam and tetrazepam) in human plasma samples. Chloroform and methanol were used as extractant and disperser solvents, respectively. The influence of several variables (e.g., type and volume of dispersant and extraction solvents, pH, ultrasonic time and ionic strength) was carefully evaluated and optimized, using an asymmetric screening design 3(2)4(2)//16. Analysis of extracts was performed by ultra-performance liquid chromatography coupled with photodiode array detection (UPLC-PDA). Under the optimum conditions, two reversed-phases, Shield RP18 and C18 columns were successfully tested, obtaining good linearity in a range of 0.01-5μgmL(-1), with correlation coefficients r>0.996. Quantification limits ranged between 4.3-13.2ngmL(-1) and 4.0-14.8ngmL(-1), were obtained for C18 and Shield RP18 columns, respectively. The optimized method exhibited a good precision level, with relative standard deviation values lower than 8%. The recoveries studied at two spiked levels, ranged from 71 to 102% for all considered compounds. The proposed method was successfully applied to the analysis of seven benzodiazepines in real human plasma samples. Copyright © 2013 Elsevier B.V. All rights reserved.

  9. Dried blood spot HIV-1 RNA quantification: A useful tool for viral load monitoring among HIV-infected individuals in India

    PubMed Central

    Neogi, Ujjwal; Gupta, Soham; Rodridges, Rashmi; Sahoo, Pravat Nalini; Rao, Shwetha D.; Rewari, Bharat B.; Shastri, Suresh; De Costa, Ayesha; Shet, Anita

    2012-01-01

    Background & objectives: Monitoring of HIV-infected individuals on antiretroviral treatment (ART) ideally requires periodic viral load measurements to ascertain adequate response to treatment. While plasma viral load monitoring is widely available in high-income settings, it is rarely used in resource-limited regions because of high cost and need for sophisticated sample transport. Dried blood spot (DBS) as source specimens for viral load measurement has shown promise as an alternative to plasma specimens and is likely to be a useful tool for Indian settings. The present study was undertaken to investigate the performance of DBS in HIV-1 RNA quantification against the standard plasma viral load assay. Methods: Between April-June 2011, 130 samples were collected from HIV-1-infected (n=125) and non-infected (n=5) individuals in two district clinics in southern India. HIV-1 RNA quantification was performed from DBS and plasma using Abbott m2000rt system after manual RNA extraction. Statistical analysis included correlation, regression and Bland-Altman analysis. Results: The sensitivity of DBS viral load was 97 per cent with viral loads >3.0 log10 copies/ml. Measurable viral load (>3.0 log 10 copies/ml) results obtained for the 74 paired plasma-DBS samples showed positive correlation between both the assays (r=0.96). For clinically acceptable viral load threshold values of >5,000 copies/ml, Bland-Altman plots showed acceptable limits of agreement (−0.21 to +0.8 log10 copies/ml). The mean difference was 0.29 log10 copies/ml. The cost of DBS was $2.67 lower compared to conventional plasma viral load measurement in the setting Interpretation & conclusions: The significant positive correlation with standard plasma-based assay and lower cost of DBS viral load monitoring suggest that DBS sampling can be a feasible and economical means of viral load monitoring in HIV-infected individual in India and in other resource-limited settings globally. PMID:23391790

  10. Onboard software of Plasma Wave Experiment aboard Arase: instrument management and signal processing of Waveform Capture/Onboard Frequency Analyzer

    NASA Astrophysics Data System (ADS)

    Matsuda, Shoya; Kasahara, Yoshiya; Kojima, Hirotsugu; Kasaba, Yasumasa; Yagitani, Satoshi; Ozaki, Mitsunori; Imachi, Tomohiko; Ishisaka, Keigo; Kumamoto, Atsushi; Tsuchiya, Fuminori; Ota, Mamoru; Kurita, Satoshi; Miyoshi, Yoshizumi; Hikishima, Mitsuru; Matsuoka, Ayako; Shinohara, Iku

    2018-05-01

    We developed the onboard processing software for the Plasma Wave Experiment (PWE) onboard the Exploration of energization and Radiation in Geospace, Arase satellite. The PWE instrument has three receivers: Electric Field Detector, Waveform Capture/Onboard Frequency Analyzer (WFC/OFA), and the High-Frequency Analyzer. We designed a pseudo-parallel processing scheme with a time-sharing system and achieved simultaneous signal processing for each receiver. Since electric and magnetic field signals are processed by the different CPUs, we developed a synchronized observation system by using shared packets on the mission network. The OFA continuously measures the power spectra, spectral matrices, and complex spectra. The OFA obtains not only the entire ELF/VLF plasma waves' activity but also the detailed properties (e.g., propagation direction and polarization) of the observed plasma waves. We performed simultaneous observation of electric and magnetic field data and successfully obtained clear wave properties of whistler-mode chorus waves using these data. In order to measure raw waveforms, we developed two modes for the WFC, `chorus burst mode' (65,536 samples/s) and `EMIC burst mode' (1024 samples/s), for the purpose of the measurement of the whistler-mode chorus waves (typically in a frequency range from several hundred Hz to several kHz) and the EMIC waves (typically in a frequency range from a few Hz to several hundred Hz), respectively. We successfully obtained the waveforms of electric and magnetic fields of whistler-mode chorus waves and ion cyclotron mode waves along the Arase's orbit. We also designed the software-type wave-particle interaction analyzer mode. In this mode, we measure electric and magnetic field waveforms continuously and transfer them to the mission data recorder onboard the Arase satellite. We also installed an onboard signal calibration function (onboard SoftWare CALibration; SWCAL). We performed onboard electric circuit diagnostics and antenna impedance measurement of the wire-probe antennas along the orbit. We utilize the results obtained using the SWCAL function when we calibrate the spectra and waveforms obtained by the PWE.[Figure not available: see fulltext.

  11. Chemical vapour deposition growth and Raman characterization of graphene layers and carbon nanotubes

    NASA Astrophysics Data System (ADS)

    Lai, Y.-C.; Rafailov, P. M.; Vlaikova, E.; Marinova, V.; Lin, S. H.; Yu, P.; Yu, S.-C.; Chi, G. C.; Dimitrov, D.; Sveshtarov, P.; Mehandjiev, V.; Gospodinov, M. M.

    2016-02-01

    Single-layer graphene films were grown by chemical vapour deposition (CVD) on Cu foil. The CVD process was complemented by plasma enhancement to grow also vertically aligned multiwalled carbon nanotubes using Ni nanoparticles as catalyst. The obtained samples were characterized by Raman spectroscopy analysis. Nature of defects in the samples and optimal growth conditions leading to achieve high quality of graphene and carbon nanotubes are discussed.

  12. Deuterium depth profile quantification in a ASDEX Upgrade divertor tile using secondary ion mass spectrometry

    NASA Astrophysics Data System (ADS)

    Ghezzi, F.; Caniello, R.; Giubertoni, D.; Bersani, M.; Hakola, A.; Mayer, M.; Rohde, V.; Anderle, M.; ASDEX Upgrade Team

    2014-10-01

    We present the results of a study where secondary ion mass spectrometry (SIMS) has been used to obtain depth profiles of deuterium concentration on plasma facing components of the first wall of the ASDEX Upgrade tokamak. The method uses primary and secondary standards to quantify the amount of deuterium retained. Samples of bulk graphite coated with tungsten or tantalum-doped tungsten are independently profiled with three different SIMS instruments. Their deuterium concentration profiles are compared showing good agreement. In order to assess the validity of the method, the integrated deuterium concentrations in the coatings given by one of the SIMS devices is compared with nuclear reaction analysis (NRA) data. Although in the case of tungsten the agreement between NRA and SIMS is satisfactory, for tantalum-doped tungsten samples the discrepancy is significant because of matrix effect induced by tantalum and differently eroded surface (W + Ta always exposed to plasma, W largely shadowed). A further comparison where the SIMS deuterium concentration is obtained by calibrating the measurements against NRA values is also presented. For the tungsten samples, where no Ta induced matrix effects are present, the two methods are almost equivalent.The results presented show the potential of the method provided that the standards used for the calibration reproduce faithfully the matrix nature of the samples.

  13. Single-step solubilization of milk samples with N,N-dimethylformamide for inductively coupled plasma-mass spectrometry analysis and classification based on their elemental composition.

    PubMed

    Azcarate, Silvana M; Savio, Marianela; Smichowski, Patricia; Martinez, Luis D; Camiña, José M; Gil, Raúl A

    2015-10-01

    A single-step procedure for trace elements analysis of milk samples is presented. Solubilization with small amounts of dymethylformamide (DMF) was assayed prior to inductively coupled plasma mass spectrometry (ICPMS) detection with a high efficiency sample introduction system. All main instrumental conditions were optimized in order to readily introduce the samples without matrix elimination. In order to assess and mitigate matrix effects in the determination of As, Cd, Co, Cu, Eu, Ga, Gd, Ge, Mn, Mo, Nb, Nd, Ni, Pb, Pr, Rb, Sm, S, Sr, Ta, Tb, V, Zn, and Zr, matrix matching calibration with (103)Rh as internal standard (IS) was performed. The obtained limits of detection were between 0.68 (Tb) and 30 (Zn) μg L(-1). For accuracy verification, certified Skim milk powder reference material (BCR 063R) was employed. The developed method was applied to trace elements analysis of commercially available milks. Principal components analysis was used to correlate the content of trace metals with the kind of milk, obtaining a classification according to adults, baby or baby fortified milks. The outcomes highlight a simple and fast approach that could be trustworthy for routine analysis, quality control and traceability of milks. Copyright © 2015 Elsevier B.V. All rights reserved.

  14. Determination of highly protein bound drugs in plasma using high-performance liquid chromatography and column switching, exemplified by the retinoids.

    PubMed

    Wyss, R; Bucheli, F

    1988-12-02

    During method development for the determination of either isotretinoin, tretinoin and their 4-oxo-metabolites, or etretinate, acitretin and 13-cis-acitretin in plasma using high-performance liquid chromatography and column switching, recovery problems arose, when undiluted plasma samples were injected directly onto the precolumn. These recovery problems may be due to the strong binding of the retinoids to different plasma proteins. Measures to overcome this strong protein binding, such as variation of the injection solution composition and the purge mobile phase, were systematically investigated. Best recoveries were obtained by diluting of plasma with 9 mM sodium hydroxide-acetonitrile (8:2, v/v) and protein precipitation with ethanol for the isotretinoin and etretinate series, respectively, in combination with the use of a purge mobile phase containing ammonium acetate and 10-20% acetonitrile. Less effective was the use of a longer precolumn or heating of the precolumn.

  15. Preliminary results from the flight of the Solar Array Module Plasma Interactions Experiment (SAMPIE)

    NASA Technical Reports Server (NTRS)

    Ferguson, Dale C.; Hillard, G. Barry

    1994-01-01

    SAMPIE, the Solar Array Module Plasma Interactions Experiment, flew in the Space Shuttle Columbia payload bay as part of the Office of Aeronautics and Space Technology-2 (OAST-2) mission on STS-62, March, 1994. SAMPIE biased samples of solar arrays and space power materials to varying potentials with respect to the surrounding space plasma, and recorded the plasma currents collected and the arcs which occurred, along with a set of plasma diagnostics data. A large set of high quality data was obtained on the behavior of solar arrays and space power materials in the space environment. This paper is the first report on the data SAMPIE telemetered to the ground during the mission. It will be seen that the flight data promise to help determine arcing thresholds, snapover potentials, and floating potentials for arrays and spacecraft in LEO.

  16. Evaluation of a direct injection nebulizer interface for flow injection analysis and high performance liquid chromatography with inductively coupled plasma-atomic emission spectroscopic detection

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    LaFreniere, K.E.

    A direct injection nebulizer (DIN) was designed, developed and evaluated to determine its potential utilization as an effective interface for flow injection analysis (FIA) and high performance liquid chromatography (HPLC) coupled with inductively coupled plasma-atomic emission spectroscopic detection. The analytical figures of merit for the DIN when used as an interface for FIA-ICP-AES were found to be comparable to or better than those obtained with conventional pneumatic nebulization in terms of limits of detection (LODs), reproducibility, linearity, and interelement effects. In the HPLC mode, the LODDs were found to be comparable to those obtained by continuous-flow sample introduction into themore » ICP, or inferior by up to only a factor of four. Stable plasma operation was maintained for the DIN sample introduction of a variety of pure organic solvents, including acetonitrile, methanol, methyl-isobutylketone, and pyridine. The HPLC-DIN-ICP-AES facility was specifically applied for the speciation of inorganic and organo-metallic species contained in synthetic mixtures, vanilla extracts and a variety of energy-related materials, such as shale oil process water, coal extracts, shale oil, crude oil, and an SRC II. Suggestions for future research are also considered.« less

  17. Direct determination of lead in biological samples by electrothermal vaporization inductively coupled plasma mass spectrometry (ETV-ICP-MS) after furnace-fusion in the sample cuvette-tungsten boat furnace.

    PubMed

    Okamoto, Y

    2000-06-01

    The newly conceived electrothermal vaporization (ETV) system using a tungsten boat furnace (TBF) sample cuvette was designed for the direct analysis of solid samples with detection by inductively coupled plasma mass spectrometry (ICP-MS). Into this small sample cuvette, a solid mixture of the biological samples and diammonium hydrogenphosphate powder as a fusion flux was placed and situated on a TBF. Tetramethylammonium hydroxide solution was added to the mixture. After the on-furnace digestion had been completed, the analyte in the cuvette was vaporized and introduced into the ICP mass spectrometer. The solid samples were analyzed by using a calibration curve prepared from the aqueous standard solutions. The detection limit was estimated to be 5.1 pg of lead, which corresponds to 10.2 ng g(-1) of lead in solid samples when a prepared sample amount of 1.0 mg was applied. The relative standard deviation for 8 replicate measurements obtained with 100 pg of lead was calculated to be 6.5%. The analytical results for various biological samples are described.

  18. Fabrication of Titanium-Niobium-Zirconium-Tantalium Alloy (TNZT) Bioimplant Components with Controllable Porosity by Spark Plasma Sintering

    PubMed Central

    Rechtin, Jack; Torresani, Elisa; Ivanov, Eugene; Olevsky, Eugene

    2018-01-01

    Spark Plasma Sintering (SPS) is used to fabricate Titanium-Niobium-Zirconium-Tantalum alloy (TNZT) powder—based bioimplant components with controllable porosity. The developed densification maps show the effects of final SPS temperature, pressure, holding time, and initial particle size on final sample relative density. Correlations between the final sample density and mechanical properties of the fabricated TNZT components are also investigated and microstructural analysis of the processed material is conducted. A densification model is proposed and used to calculate the TNZT alloy creep activation energy. The obtained experimental data can be utilized for the optimized fabrication of TNZT components with specific microstructural and mechanical properties suitable for biomedical applications. PMID:29364165

  19. Clinical evaluation of plasma insulin and C-peptide levels with 3 different high-flux dialyzers in diabetic patients on hemodialysis.

    PubMed

    Abe, M; Okada, K; Maruyama, T; Inoshita, A; Ikeda, K; Uto, E; Kikuchi, F; Matsumoto, K

    2008-10-01

    Changes in plasma immunoreactive insulin (IRI) and connecting-peptide immunoreactivity (CPR) concentrations during hemodialysis (HD) were evaluated in diabetic HD patients with 3 different high-flux membranes. The removal properties of the membranes were compared. In this prospective controlled study, 15 stable diabetic patients on HD were randomly selected for 6 HD sessions with 3 different membranes: polysulfone (PS), cellulose triacetate (CTA), and polymethylmethacrylate (PMMA). Blood samples were obtained from the blood tubing at the arterial (A) site at the beginning and end of the sixth HD session. At 60 minutes after dialysis initiation, blood samples were obtained from both the A and venous (V) sites of the dialyzer to investigate the clearance and removal properties of the membranes. The plasma IRI and CPR levels decreased significantly at each time point with all 3 membranes. IRI clearance with the PS membrane was significantly higher than that with the CTA and PMMA membranes. No difference was observed in the IRI reduction rate between the 3 membranes. CPR clearance and reduction rate with the PMMA membrane were lower than with the PS and CTA membranes. No significant difference was observed in serum creatinine clearance and reduction rates between the 3 membranes; however, serum urea nitrogen clearance was significantly lower with the PMMA membrane compared with the PS and CTA membranes. A significantly high beta2-microglobulin clearance and reduction rate was achieved in the order PS > CTA > PMMA. Plasma IRI and CPR are cleared by HD; their clearance rates differ with the dialyzer membranes. Plasma IRI clearance with the PS membrane is higher than that with the CTA and PMMA membranes.

  20. Lithium loss in the solid electrolyte interphase: Lithium quantification of aged lithium ion battery graphite electrodes by means of laser ablation inductively coupled plasma mass spectrometry and inductively coupled plasma optical emission spectroscopy

    NASA Astrophysics Data System (ADS)

    Schwieters, Timo; Evertz, Marco; Mense, Maximilian; Winter, Martin; Nowak, Sascha

    2017-07-01

    In this work we present a new method using LA-ICP-MS to quantitatively determine the lithium content in aged graphite electrodes of a lithium ion battery (LIB) by performing total depth profiling. Matrix matched solid external standards are prepared using a solid doping approach to avoid elemental fractionation effects during the measurement. The results are compared and matched to the established ICP-OES technique for bulk quantification after performing a microwave assisted acid digestion. The method is applied to aged graphite electrodes in order to determine the lithium immobilization (= "Li loss") in the solid electrolyte interphase after the first cycle of formation. For this, different samples including a reference sample are created to obtain varying thicknesses of the SEI covering the electrode particles. By applying defined charging voltages, an initial lithiation process is performed to obtain specific graphite intercalation compounds (GICs, with target stoichiometries of LiC30, LiC18, LiC12 and LiC6). Afterwards, the graphite electrode is completely discharged to obtain samples without mobile, thus active lithium in its lattice. Taking the amount of lithium into account which originates from the residues of the LiPF6 (dissolved in the carbon components containing electrolyte), it is possible to subtract the amount of lithium in the SEI.

  1. Calculation of sheath and wake structure about a pillbox-shaped spacecraft in a flowing plasma

    NASA Technical Reports Server (NTRS)

    Parker, L. W.

    1977-01-01

    A computer program was used for studies of the disturbed zones around bodies in flowing plasmas, particularly spacecraft and their associated sheaths and wakes. The program solved a coupled Poisson-Vlasov system of nonlinear partial differential integral equations to obtain distributions of electric potential and ion and electron density about a finite length cylinder in a plasma flow at arbitrary ion Mach numbers. The approach was applicable to a larger range of parameters than other available approaches. In sample calculations, bodies up to 100 Debye lengths in radius were treated, that is, larger than any previously treated realistically. Applications were made to in-situ satellite experiments.

  2. Characteristics of canine platelet-rich plasma prepared with five commercially available systems.

    PubMed

    Franklin, Samuel P; Garner, Bridget C; Cook, James L

    2015-09-01

    To characterize platelet-rich plasma (PRP) products obtained from canine blood by use of a variety of commercially available devices. Blood samples from 15 dogs between 18 months and 9 years of age with no concurrent disease, except for osteoarthritis in some dogs. PRP products were produced from blood obtained from each of the 15 dogs by use of each of 5 commercially available PRP-concentrating systems. Complete blood counts were performed on each whole blood sample and PRP product. The degree of platelet, leukocyte, and erythrocyte concentration or reduction for PRP, compared with results for the whole blood sample, was quantified for each dog and summarized for each concentrating system. The various PRP-concentrating systems differed substantially in the amount of blood processed, method of PRP preparation, amount of PRP produced, and platelet, leukocyte, and erythrocyte concentrations or reductions for PRP relative to results for whole blood. The characteristics of PRP products differed considerably. Investigators evaluating the efficacy of PRPs need to specify the characteristics of the product they are assessing. Clinicians should be aware of the data (or lack of data) supporting use of a particular PRP for a specific medical condition.

  3. Detection of beryllium in digested autopsy tissues by inductively coupled plasma mass spectrometry using a high matrix interface configuration.

    PubMed

    Larivière, Dominic; Tremblay, Mélodie; Durand-Jézéquel, Myriam; Tolmachev, Sergei

    2012-04-01

    This article describes a robust methodology using the combination of instrumental design (high matrix interface-HMI), sample dilution and internal standardization for the quantification of beryllium (Be) in various digested autopsy tissues using inductively coupled plasma mass spectrometry. The applicability of rhodium as a proper internal standard for Be was demonstrated in three types of biological matrices (i.e., femur, hair, lung tissues). Using HMI, it was possible to achieve instrumental detection limits and sensitivity of 0.6 ng L(-1) and 157 cps L ng(-1), respectively. Resilience to high salt matrices of the HMI setup was also highlighted using bone mimicking solution ([Ca(2+)] = 26 to 1,400 mg L(-1)), providing a 14-fold increase in tolerance and a 2.7-fold decrease in method detection limit compared to optimized experimental conditions obtained without the HMI configuration. Precision of the methodology to detect low levels of Be in autopsy samples was demonstrated using hair and blood certified reference materials. Be concentration ranging from 0.015 to 255 μg kg(-1) in autopsy samples obtained from the U.S. Transuranium and Uranium Registries were measured using the methodology presented.

  4. HIV-1 viral load measurement in venous blood and fingerprick blood using Abbott RealTime HIV-1 DBS assay.

    PubMed

    Tang, Ning; Pahalawatta, Vihanga; Frank, Andrea; Bagley, Zowie; Viana, Raquel; Lampinen, John; Leckie, Gregor; Huang, Shihai; Abravaya, Klara; Wallis, Carole L

    2017-07-01

    HIV RNA suppression is a key indicator for monitoring success of antiretroviral therapy. From a logistical perspective, viral load (VL) testing using Dried Blood Spots (DBS) is a promising alternative to plasma based VL testing in resource-limited settings. To evaluate the analytical and clinical performance of the Abbott RealTime HIV-1 assay using a fully automated one-spot DBS sample protocol. Limit of detection (LOD), linearity, lower limit of quantitation (LLQ), upper limit of quantitation (ULQ), and precision were determined using serial dilutions of HIV-1 Virology Quality Assurance stock (VQA Rush University), or HIV-1-containing armored RNA, made in venous blood. To evaluate correlation, bias, and agreement, 497 HIV-1 positive adult clinical samples were collected from Ivory Coast, Uganda and South Africa. For each HIV-1 participant, DBS-fingerprick, DBS-venous and plasma sample results were compared. Correlation and bias values were obtained. The sensitivity and specificity were analyzed at a threshold of 1000 HIV-1 copies/mL generated using the standard plasma protocol. The Abbott HIV-1 DBS protocol had an LOD of 839 copies/mL, a linear range from 500 to 1×10 7 copies/mL, an LLQ of 839 copies/mL, a ULQ of 1×10 7 copies/mL, and an inter-assay SD of ≤0.30 log copies/mL for all tested levels within this range. With clinical samples, the correlation coefficient (r value) was 0.896 between DBS-fingerprick and plasma and 0.901 between DBS-venous and plasma, and the bias was -0.07 log copies/mL between DBS-fingerprick and plasma and -0.02 log copies/mL between DBS-venous and plasma. The sensitivity of DBS-fingerprick and DBS-venous was 93%, while the specificity of both DBS methods was 95%. The results demonstrated that the Abbott RealTime HIV-1 assay with DBS sample protocol is highly sensitive, specific and precise across a wide dynamic range and correlates well with plasma values. The Abbott RealTime HIV-1 assay with DBS sample protocol provides an alternative sample collection and transfer option in resource-limited settings and expands the utility of a viral load test to monitor HIV-1 ART treatment for infected patients. Copyright © 2017 The Author(s). Published by Elsevier B.V. All rights reserved.

  5. Molybdenum and carbon atom and carbon cluster sputtering under low-energy noble gas plasma bombardment

    NASA Astrophysics Data System (ADS)

    Oyarzabal, Eider

    Exit-angle resolved Mo atom sputtering yield under Xe ion bombardment and carbon atom and cluster (C2 and C3) sputtering yields under Xe, Kr, Ar, Ne and He ion bombardment from a plasma are measured for low incident energies (75--225 eV). An energy-resolved quadrupole mass spectrometer (QMS) is used to detect the fraction of un-scattered sputtered neutrals that become ionized in the plasma; the angular distribution is obtained by changing the angle between the target and the QMS aperture. A one-dimensional Monte Carlo code is used to simulate the interaction of the plasma and the sputtered particles between the sample and the QMS. The elastic scattering cross-sections of C, C2 and C3 with the different bombarding gas neutrals is obtained by varying the distance between the sample and the QMS and by performing a best fit of the simulation results to the experimental results. Because the results obtained with the QMS are relative, the Mo atom sputtering results are normalized to the existing data in the literature and the total sputtering yield for carbon (C+C 2+C3) for each bombarding gas is obtained from weight loss measurements. The absolute sputtering yield for C, C2 and C 3 is then calculated from the integration of the measured angular distribution, taking into account the scattering and ionization of the sputtered particles between the sample and the QMS. The angular sputtering distribution for Mo has a maximum at theta=60°, and this maximum becomes less pronounced as the incident ion energy increases. The results of the Monte Carlo TRIDYN code simulation for the angular distribution of Mo atoms sputtered by Xe bombardment are in agreement with the experiments. For carbon sputtering under-cosine angular distributions of the sputtered atoms and clusters for all the studied bombarding gases are also observed. The C, C2 and C3 sputtering yield data shows a clear decrease of the atom to cluster (C/C2 and C/C3) sputtering ratio as the incident ion mass increases, changing from a carbon atom preferential erosion for the lower incident ion masses (He, Ne and Ar) to a cluster preferential erosion for the higher incident ion masses (Kr and Xe).

  6. Determination of the neuropharmacological drug nodakenin in rat plasma and brain tissues by liquid chromatography tandem mass spectrometry: Application to pharmacokinetic studies.

    PubMed

    Song, Yingshi; Yan, Huiyu; Xu, Jingbo; Ma, Hongxi

    2017-09-01

    A rapid and sensitive liquid chromatography tandem mass spectrometry detection using selected reaction monitoring in positive ionization mode was developed and validated for the quantification of nodakenin in rat plasma and brain. Pareruptorin A was used as internal standard. A single step liquid-liquid extraction was used for plasma and brain sample preparation. The method was validated with respect to selectivity, precision, accuracy, linearity, limit of quantification, recovery, matrix effect and stability. Lower limit of quantification of nodakenin was 2.0 ng/mL in plasma and brain tissue homogenates. Linear calibration curves were obtained over concentration ranges of 2.0-1000 ng/mL in plasma and brain tissue homogenates for nodakenin. Intra-day and inter-day precisions (relative standard deviation, RSD) were <15% in both biological media. This assay was successfully applied to plasma and brain pharmacokinetic studies of nodakenin in rats after intravenous administration. Copyright © 2017 John Wiley & Sons, Ltd.

  7. Plasma endotoxin activity in Eastern grey kangaroos (Macropus giganteus) with lumpy jaw disease.

    PubMed

    Sotohira, Yukari; Suzuki, Kazuyuki; Otsuka, Marina; Tsuchiya, Masakazu; Shimamori, Toshio; Nishi, Yasunobu; Tsukano, Kenji; Asakawa, Mitsuhiko

    2017-06-29

    Progressive pyogranulomatous osteomyelitis involving the mandible or maxilla of captive macropods, referred to as "Lumpy jaw disease (LJD)", is one of the most significant causes of illness and death in captive macropods. The aim of the present study was to evaluate the relationship between the severity of LJD and plasma endotoxin activity in kangaroos. Plasma samples obtained from moderate (n=24) and severe LJD (n=12), and healthy kangaroos (n=46), were diluted 1:20 in endotoxin-free water and heated to 80°C for 10 min. Plasma endotoxin activity was measured using the Limulus amebocyte lysate (LAL)-kinetic turbidimetric (KT) assay. Plasma endotoxin activity was higher in kangaroos with severe LJD (0.199 ± 0.157 EU/ml) than in those with moderate LJD (0.051 ± 0.012 EU/ml, P<0.001) and healthy controls (0.057 ± 0.028 EU/ml, P<0.001). Our results suggest that the severity of LJD in captive macropods may be related to the plasma endotoxin activity.

  8. Solid-phase microextraction low temperature plasma mass spectrometry for the direct and rapid analysis of chemical warfare simulants in complex mixtures.

    PubMed

    Dumlao, Morphy C; Jeffress, Laura E; Gooding, J Justin; Donald, William A

    2016-06-21

    Solid-phase microextraction (SPME) is directly integrated with low temperature plasma ionisation mass spectrometry to rapidly detect organophosphate chemical warfare agent simulants and their hydrolysis products in chemical mixtures, including urine. In this sampling and ionization method, the fibre serves: (i) to extract molecules from their native environment, and (ii) as the ionization electrode that is used to desorb and ionize molecules directly from the SPME surface. By use of a custom fabricated SPME fibre consisting of a stainless steel needle coated with a Linde Type A (LTA) zeolitic microporous material and low temperature plasma mass spectrometry, protonated dimethyl methylphosphonate (DMMP), diethyl ethylphosphonate (DEEP) and pinacolyl methylphosphonic acid (PinMPA) can be detected at less than 100 ppb directly in water and urine. Organophosphates were not readily detected by this approach using an uncoated needle in negative control experiments. The use of the LTA coating significantly outperformed the use of a high alumina Zeolite Socony Mobil-5 (ZSM-5) coating of comparable thickness that is significantly less polar than LTA. By conditioning the LTA probe by immersion in an aqueous CuSO4 solution, the ion abundance for protonated DMMP increased by more than 300% compared to that obtained without any conditioning. Sample recovery values were between 96 and 100% for each analyte. The detection of chemical warfare agent analogues and hydrolysis products required less than 2 min per sample. A key advantage of this sampling and ionization method is that analyte ions can be directly and rapidly sampled from chemical mixtures, such as urine and seawater, without sample preparation or chromatography for sensitive detection by mass spectrometry. This ion source should prove beneficial for portable mass spectrometry applications because relatively low detection limits can be obtained without the use of compressed gases, fluid pumps, and lasers. Moreover, the ion source is compact, can be powered with a 10 V battery, and is tolerant of complex mixtures.

  9. Physiological and Pathological Impact of Blood Sampling by Retro-Bulbar Sinus Puncture and Facial Vein Phlebotomy in Laboratory Mice

    PubMed Central

    Holst, Birgitte; Hau, Jann; Rozell, Björn; Abelson, Klas Stig Peter

    2014-01-01

    Retro-bulbar sinus puncture and facial vein phlebotomy are two widely used methods for blood sampling in laboratory mice. However, the animal welfare implications associated with these techniques are currently debated, and the possible physiological and pathological implications of blood sampling using these methods have been sparsely investigated. Therefore, this study was conducted to assess and compare the impacts of blood sampling by retro-bulbar sinus puncture and facial vein phlebotomy. Blood was obtained from either the retro-bulbar sinus or the facial vein from male C57BL/6J mice at two time points, and the samples were analyzed for plasma corticosterone. Body weights were measured at the day of blood sampling and the day after blood sampling, and the food consumption was recorded automatically during the 24 hours post-procedure. At the end of study, cheeks and orbital regions were collected for histopathological analysis to assess the degree of tissue trauma. Mice subjected to facial vein phlebotomy had significantly elevated plasma corticosterone levels at both time points in contrast to mice subjected to retro-bulbar sinus puncture, which did not. Both groups of sampled mice lost weight following blood sampling, but the body weight loss was higher in mice subjected to facial vein phlebotomy. The food consumption was not significantly different between the two groups. At gross necropsy, subcutaneous hematomas were found in both groups and the histopathological analyses revealed extensive tissue trauma after both facial vein phlebotomy and retro-bulbar sinus puncture. This study demonstrates that both blood sampling methods have a considerable impact on the animals' physiological condition, which should be considered whenever blood samples are obtained. PMID:25426941

  10. Plasma-grafting polymerization on carbon fibers and its effect on their composite properties

    NASA Astrophysics Data System (ADS)

    Zhang, Huanxia; Li, Wei

    2015-11-01

    Interfacial adhesion between matrix and fibers plays a crucial role in controlling the performance of composites. Carbon fibers have the major constraint of chemical interness and hence have limited adhesion with the matrix. Surface treatment of fibers is the best solution to this problem. In this work, carbon fibers were activated by plasma and grafting polymerization. The grafting ratio of polymerization was obtained by acid-base titration. The chemical and physical changes induced by the treatments on carbon fiber surface was examined using contact angle measurements, X-ray photoelectron spectroscopy (XPS), and Fourier-transform infrared spectroscopy-attenuated total reflectance (FTIR-ATR) technique. The interfacial adhesion of CF/EP (carbon fiber/epoxy) composites were analyzed by a single fiber composite (SFC) for filament fragmentation test. Experimental results show that the grafting rate was not only the function of the plasma-treat time but also the concentration of the grafting polymerization. The oxygen-containing groups (such as Csbnd O, Cdbnd O, and Osbnd Cdbnd O) and the interfacial shear strength (IFSS) of the plasma-grafting carbon fiber increased more significantly than the carbon fiber without plasma treatment grafted with MAH. This demonstrates that the surfaces of the carbon fiber samples are more active, hydrophilic, and rough after plasma-grafting treatments using a DBD operating in ambient argon mixture with oxygen. With DBD (dielectric barrier discharges) operating in ambient argon mixture with oxygen, the more active, hydrophilic, and rough surface was obtained by the plasma-grafting treatments.

  11. Metabolic Signature of Remote Ischemic Preconditioning Involving a Cocktail of Amino Acids and Biogenic Amines.

    PubMed

    Chao de la Barca, Juan Manuel; Bakhta, Oussama; Kalakech, Hussein; Simard, Gilles; Tamareille, Sophie; Catros, Véronique; Callebert, Jacques; Gadras, Cédric; Tessier, Lydie; Reynier, Pascal; Prunier, Fabrice; Mirebeau-Prunier, Delphine

    2016-09-24

    Remote ischemic preconditioning (RIPC) is an attractive therapeutic procedure for protecting the heart against ischemia/reperfusion injury. Despite evidence of humoral mediators transported through the circulation playing a critical role, their actual identities so far remain unknown. We sought to identify plasmatic RIPC-induced metabolites that may play a role. Rat plasma samples from RIPC and control groups were analyzed using a targeted metabolomic approach aimed at measuring 188 metabolites. Principal component analysis and orthogonal partial least-squares discriminant analysis were used to identify the metabolites that discriminated between groups. Plasma samples from 50 patients subjected to RIPC were secondarily explored to confirm the results obtained in rats. Finally, a combination of the metabolites that were significantly increased in both rat and human plasma was injected prior to myocardial ischemia/reperfusion in rats. In the rat samples, 124 molecules were accurately quantified. Six metabolites (ornithine, glycine, kynurenine, spermine, carnosine, and serotonin) were the most significant variables for marked differentiation between the RIPC and control groups. In human plasma, analysis confirmed ornithine decrease and kynurenine and glycine increase following RIPC. Injection of the glycine and kynurenine alone or in combination replicated the protective effects of RIPC seen in rats. We have hereby reported significant variations in a cocktail of amino acids and biogenic amines after remote ischemic preconditioning in both rat and human plasma. URL: http://www.clinicaltrials.gov. Unique identifier: NCT01390129. © 2016 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley Blackwell.

  12. Novel system using microliter order sample volume for measuring arterial radioactivity concentrations in whole blood and plasma for mouse PET dynamic study.

    PubMed

    Kimura, Yuichi; Seki, Chie; Hashizume, Nobuya; Yamada, Takashi; Wakizaka, Hidekatsu; Nishimoto, Takahiro; Hatano, Kentaro; Kitamura, Keishi; Toyama, Hiroshi; Kanno, Iwao

    2013-11-21

    This study aimed to develop a new system, named CD-Well, for mouse PET dynamic study. CD-Well allows the determination of time-activity curves (TACs) for arterial whole blood and plasma using 2-3 µL of blood per sample; the minute sample size is ideal for studies in small animals. The system has the following merits: (1) measures volume and radioactivity of whole blood and plasma separately; (2) allows measurements at 10 s intervals to capture initial rapid changes in the TAC; and (3) is compact and easy to handle, minimizes blood loss from sampling, and delay and dispersion of the TAC. CD-Well has 36 U-shaped channels. A drop of blood is sampled into the opening of the channel and stored there. After serial sampling is completed, CD-Well is centrifuged and scanned using a flatbed scanner to define the regions of plasma and blood cells. The length measured is converted to volume because the channels have a precise and uniform cross section. Then, CD-Well is exposed to an imaging plate to measure radioactivity. Finally, radioactivity concentrations are computed. We evaluated the performance of CD-Well in in vitro measurement and in vivo (18)F-fluorodeoxyglucose and [(11)C]2-carbomethoxy-3β-(4-fluorophenyl) tropane studies. In in vitro evaluation, per cent differences (mean±SE) from manual measurement were 4.4±3.6% for whole blood and 4.0±3.5% for plasma across the typical range of radioactivity measured in mouse dynamic study. In in vivo studies, reasonable TACs were obtained. The peaks were captured well, and the time courses coincided well with the TAC derived from PET imaging of the heart chamber. The total blood loss was less than 200 µL, which had no physiological effect on the mice. CD-Well demonstrates satisfactory performance, and is useful for mouse PET dynamic study.

  13. Value of Routine Dengue Diagnostic Tests in Urine and Saliva Specimens

    PubMed Central

    Andries, Anne-Claire; Duong, Veasna; Ly, Sowath; Cappelle, Julien; Kim, Kim Srorn; Lorn Try, Patrich; Ros, Sopheaktra; Ong, Sivuth; Huy, Rekol; Horwood, Paul; Flamand, Marie; Sakuntabhai, Anavaj; Tarantola, Arnaud; Buchy, Philippe

    2015-01-01

    Background Dengue laboratory diagnosis is essentially based on detection of the virus, its components or antibodies directed against the virus in blood samples. Blood, however, may be difficult to draw in some patients, especially in children, and sampling during outbreak investigations or epidemiological studies may face logistical challenges or limited compliance to invasive procedures from subjects. The aim of this study was to assess the possibility of using saliva and urine samples instead of blood for dengue diagnosis. Methodology/Principal Findings Serial plasma, urine and saliva samples were collected at several time-points between the day of admission to hospital until three months after the onset of fever in children with confirmed dengue disease. Quantitative RT-PCR, NS1 antigen capture and ELISA serology for anti-DENV antibody (IgG, IgM and IgA) detection were performed in parallel on the three body fluids. RT-PCR and NS1 tests demonstrated an overall sensitivity of 85.4%/63.4%, 41.6%/14.5% and 39%/28.3%, in plasma, urine and saliva specimens, respectively. When urine and saliva samples were collected at the same time-points and tested concurrently, the diagnostic sensitivity of RNA and NS1 detection assays was 69.1% and 34.4%, respectively. IgG/IgA detection assays had an overall sensitivity of 54.4%/37.4%, 38.5%/26.8% and 52.9%/28.6% in plasma, urine and saliva specimens, respectively. IgM were detected in 38.1% and 36% of the plasma and saliva samples but never in urine. Conclusions Although the performances of the different diagnostic methods were not as good in saliva and urine as in plasma specimens, the results obtained by qRT-PCR and by anti-DENV antibody ELISA could well justify the use of these two body fluids to detect dengue infection in situations when the collection of blood specimens is not possible. PMID:26406240

  14. Lassa Fever Immune Plasma.

    DTIC Science & Technology

    1986-05-01

    obtained and 317 forwarded to USAMRIID, with 272 having LNI’s of 0.3 or higher. Testing of febrile patients for evidence of Lassa virus (LV) infection ...at a rehabilitation center near GWH revealed evidence of previous LV infection in 22 of 288 leprosy patients, 4 of 52 family members of these patients...Virus Infections in the Families of Lassa Fever Patients Annex 3. Record of Household Epidemiology Study 49 Annex 4. Means of Obtaining Samples for IFA

  15. One mouse, one pharmacokinetic profile: quantitative whole blood serial sampling for biotherapeutics.

    PubMed

    Joyce, Alison P; Wang, Mengmeng; Lawrence-Henderson, Rosemary; Filliettaz, Cynthia; Leung, Sheldon S; Xu, Xin; O'Hara, Denise M

    2014-07-01

    The purpose of this study was to validate the approach of serial sampling from one mouse through ligand binding assay (LBA) quantification of dosed biotherapeutic in diluted whole blood to derive a pharmacokinetic (PK) profile. This investigation compared PK parameters obtained using serial and composite sampling methods following administration of human IgG monoclonal antibody. The serial sampling technique was established by collecting 10 μL of blood via tail vein at each time point following drug administration. Blood was immediately diluted into buffer followed by analyte quantitation using Gyrolab to derive plasma concentrations. Additional studies were conducted to understand matrix and sampling site effects on drug concentrations. The drug concentration profiles, irrespective of biological matrix, and PK parameters using both sampling methods were not significantly different. There were no sampling site effects on drug concentration measurements except that concentrations were slightly lower in sodium citrated plasma than other matrices. We recommend the application of mouse serial sampling, particularly with limiting drug supply or specialized animal models. Overall the efficiencies gained by serial sampling were 40-80% savings in study cost, animal usage, study length and drug conservation while inter-subject variability across PK parameters was less than 30%.

  16. Spectroscopic measurements of muzzle flash plasma

    NASA Astrophysics Data System (ADS)

    Uglum, J. R.

    1986-11-01

    The experimental apparatus and sample data for the muzzle flash plasma of a laboratory-scale railgun are described. Theoretical predictions for the railgun system configuration used indicated that 24 kJ of energy would be dissipated by the muzzle flash. Spectral data were recorded with a spectrograph sensing through a slit and a PIN diode, the latter to obtain temporal resolution in the data. The tests featured a plastic projectile with an Al foil armature. The measurements identified Cu as the dominant flash material, ablated from the rails in the barrel.

  17. Evaluation of microbial contamination of canine plasma eyedropper bottles following clinical use in canine patients.

    PubMed

    Strauss, Rachel A; Genschel, Ulrike; Allbaugh, Rachel A; Sebbag, Lionel; Ben-Shlomo, Gil

    2018-05-24

    To investigate microbial contamination of canine plasma eye drops when used clinically and to compare the effect of two different eyedropper bottles on contamination rate. Forty-six bottles containing plasma were randomly dispensed for use on 42 dogs with ulcerative keratitis. Of these, 23 were standard eyedropper bottles and 23 were Novelia ® bottles designed to prevent contamination. After use for up to 2 weeks, samples for bacterial culture were obtained from a drop of plasma, the bottle tip, the plasma inside the bottle, and the corneal surface. Fungal culture was performed from a drop of plasma. The overall microbial contamination rate was 17.4% (8/46 bottles); however, only one bottle had growth from the plasma inside the bottle. There was a lower contamination rate of Novelia ® bottles (3/23 = 13.0%) compared to standard bottles (5/23 = 21.7%), but this difference was not statistically significant (P = .57). There were also no significant differences in contamination rate of bottles used greater than 7 days compared to less than or equal to 7 days, or in bottles used greater than 4 times daily compared to 4 times daily or less. Three corneal samples (6.5%) had bacterial growth, but none matched contamination from the bottles. Novelia ® bottles may decrease contamination of plasma eye drops used clinically. However, while microbial contamination of plasma bottles was documented, no clinically relevant complications were observed. This study supports safe use of plasma eye drops for up to 2 weeks when refrigerated and dispensed from either Novelia ® or standard eyedropper bottles. © 2018 American College of Veterinary Ophthalmologists.

  18. Evaluation of a dried blood and plasma collection device, SampleTanker(®), for HIV type 1 drug resistance genotyping in patients receiving antiretroviral therapy.

    PubMed

    Diallo, Karidia; Lehotzky, Erica; Zhang, Jing; Zhou, Zhiyong; de Rivera, Ivette Lorenzana; Murillo, Wendy E; Nkengasong, John; Sabatier, Jennifer; Zhang, Guoqing; Yang, Chunfu

    2014-01-01

    Whatman 903 filter paper is the only filter paper that has been used for HIV drug resistance (HIVDR) genotyping in resource-limited settings. In this study, we evaluated another dried blood specimen collection device, termed SampleTanker(®) (ST), for HIVDR genotyping. Blood specimens from 123 antiretroviral therapy (ART)-experienced patients were used to prepare ST whole blood and ST plasma specimens; they were then stored at ambient temperature for 2 or 4 weeks. The remaining plasma specimens were stored at -80°C and used as frozen plasma controls. Frozen plasma viral load (VL) was determined using the Roche Amplicor HIV-1 Monitor test, v.1.5 and 50 specimens with VL ≥3.00 log10 copies/ml were genotyped using the broadly sensitive genotyping assay. The medium VL for the 50 frozen plasma specimens with VL ≥3.00 log10 was 3.58 log10 copies/ml (IQR: 3.32-4.11) and 96.0% (48/50) of them were genotyped. Comparing to frozen plasma specimens, significantly lower genotyping rates were obtained from ST whole blood (48.98% and 42.85%) and ST plasma specimens (36.0% and 36.0%) stored at ambient temperature for 2 and 4 weeks, respectively (p<0.001). Nucleotide sequence identity and resistance profile analyses between the matched frozen plasma and ST whole blood or ST plasma specimens revealed high nucleotide sequence identities and concordant resistance profiles (98.1% and 99.0%, and 96.6% and 98.9%, respectively). Our results indicate that with the current design, the ST may not be the ideal dried blood specimen collection device for HIVDR monitoring for ART patients in resource-limited settings.

  19. A comparative bear model for immobility-induced osteopenia

    NASA Technical Reports Server (NTRS)

    Milbury, P. E.; Vaughan, M. R.; Farley, S.; Matula, G. J. Jr; Convertino, V. A.; Matson, W. R.

    1998-01-01

    The National Institutes of Health (NIH) and the National Aeronautics and Space Administration (NASA) are seeking solutions to the human problem of osteopenia, or immobility-induced bone loss. Bears, during winter dormancy, appear uniquely exempted from the debilitating effects of immobility osteopenia. NIH and ESA, Inc. are creating a large database of metabolic information on human ambulatory and bedrest plasma samples for comparison with metabolic data obtained from bear plasma samples collected in different seasons. The database generated from NASA's HR113 human bedrest study showed a clear difference between plasma samples of ambulatory and immobile subjects through cluster analysis using compounds determined by high performance liquid chromatography with coulometric electrochemical array detection (HPLC-EC). We collected plasma samples from black bears (Ursus americanus) across 4 seasons and from 3 areas and subjected them to similar analysis, with particular attention to compounds that changed significantly in the NASA human study. We found seasonal differences in 28 known compounds and 33 unknown compounds. A final database contained 40 known and 120 unknown peaks that were reliably assayed in all bear and human samples; these were the primary data set for interspecies comparison. Six unidentified compounds changed significantly but differentially in wintering bears and immobile humans. The data are discussed in light of current theories regarding dormancy, starvation, and anabolic metabolism. Work is in progress by ESA Laboratories on a larger database to confirm these findings prior to a chemical isolation and identification effort. This research could lead to new pharmaceuticals or dietary interventions for the treatment of immobility osteopenia.

  20. The microwave induced plasma with optical emission spectrometry (MIP-OES) in 23 elements determination in geological samples.

    PubMed

    Niedzielski, P; Kozak, L; Wachelka, M; Jakubowski, K; Wybieralska, J

    2015-01-01

    The article presents the optimisation, validation and application of the microwave induced plasma optical emission spectrometry (MIP-OES) dedicated for a routine determination of Ag, Al, B, Ba, Bi, Ca, Cd, Cr, Cu, Fe, Ga, In, K, Li, Mg, Mn, Mo, Na, Ni, Pb, Sr, Tl, Zn, in the geological samples. The three procedures of sample preparation has been proposed: sample digestion with the use of hydrofluoric acid for determination of total concentration of elements, extraction by aqua regia for determination of the quasi-total element concentration and extraction by hydrochloric acid solution to determine contents of the elements in acid leachable fraction. The detection limits were on the level 0.001-0.121 mg L(-1) (from 0.010-0.10 to 1.2-12 mg kg(-1) depend on the samples preparation procedure); the precision: 0.20-1.37%; accuracy 85-115% (for recovery for certified standards materials analysis and parallel analysis by independent analytical techniques: X-ray fluorescence (XRF) and flame absorption spectrometry (FAAS)). The conformity of the results obtained by MIP-OES analytical procedures with the results obtained by XRF and FAAS analysis allows to propose the procedures for studies of elemental composition of the fraction of the geological samples. Additionally, the MIP-OES technique is much less expensive than ICP techniques and much less time-consuming than AAS techniques. Copyright © 2014 Elsevier B.V. All rights reserved.

  1. The Modification of Cellulosic Surface with Fatty Acids via Plasma Mediated Reactions

    NASA Astrophysics Data System (ADS)

    Nada, Ahmed Ali Ahmed

    Much attention has been paid recently to understand the healing process made by the human body, in order to develop new approaches for promoting healing. The wound healing process includes four main phases, namely, hemostatic, inflammatory, proliferation, and remodeling, which take place successively. The human body can provide all the requirements of the healing process in normal wounds, unless there is a kind of deficiency of the skin function or massive fluid losses of vast wounds. Therefore, wound care of non-healing wounds has recently been the growing concern of many applications. The goal of this work is to explore the development of a new cellulose-based wound dressing composite that contain or release wound healing agents attained via dry textile chemical finishing techniques (thermal curing-plasma treatment). The synthesis of different wound healing agents derived from fatty acids and attached chemically to cellulose or even delivered through cyclodextrine modified cellulose are reported in this work. First, free fatty acids, which are obtained from commercial vegetable oils, were identified as wound healing agents. Many of these free acids are known to bind with and deactivate the proteases associated with inflammation at a wound site. Linoleic acid is extracted from commercial products of safflower seed oil while ricinoleic acid is obtained from castor oil. Conjugated linoleic acid was synthesized. Un-conjugated linoleic acid was used to prepare two derivatives namely linoleic azide and allylic ketone of linoleic acid. Different cellulose derivatives such as cellulose peroxide, iododeoxycellulose and cellulose diazonium salt in different degree of substitutions were synthesized in order to facilitate the free radical reaction with the fatty acid derivatives. New modified cellulosic products were synthesized by reacting the cellulosic and the linoleic acid derivatives via thermal or plasma technique and characterized by FT-IR ATR, the wettability test, etc. The cyto-compatiability of the new product was investigated using the cytotoxicity test to identify the cytotoxic potentials of the grafted samples. The highest yield was obtained in the thermal curing (at 140°C, 3 min, and a 20% solution of azide derivative -- 170°C, 3 min, and a 2.5% solution of allylic ketone derivatives) of the iododeoxycellulose fabrics with either linoleic azide or the allylic ketone derivative. Atmospheric plasma machines were used for this study such as NCAPS (dielectric barrier discharge plasma) and APJeT. APJet plasma machine was used in two different modes namely downstream and in-situ. Although, the plasma treatment uses a lower energy to achieve the chemical reactions between the two components, the APJet obtained good results in the in-situ mode (at 800 Watts/cm3 RF power, 45 sec. exposure time) while retaining sufficient tensile strength. In general samples treated with the allylic ketone of linoleic acid treated samples showed higher graft yield than the azide derivative, especially those treated via thermal curing. Moreover, they are more cytologically compatible than the plasma treated samples. In the course of producing a wound healing product that contains or releases fatty acids, allylic beta-CD was synthesized for first time as a textile finishing agent. Per(2, 3, 6- tri-O-allyl)-beta-CD was synthesized and characterized using spectral analysis. Cellulosic derivatives were treated with per(2, 3, 6- tri-O-allyl)-beta-CD via either pad-thermofixation technique or plasma treatment. Thermal treatment showed superior efficiency over plasma techniques to activate the vinyl groups and creating a self-assembled CD network chemically bonded with the cellulose derivatives (at 180°C, 3 min, and a 20 % solution of Per(2, 3, 6- tri- O-allyl)-beta-CD). APJeT machine (in-situ mode) succeeded only to activate cellulose/ allylic CD reaction, but however, it could not offer enough energy to stimulate vinyl-vinyl reactions. Oleic acid with its semi-linear chemical structure tends to include in the CD cavity faster and to higher levels, than the others after 4 hrs at 25°C. At higher temperatures the equilibrium of free and included oleic acid shifts and a remarkable decrease in the total inclusion was observed. However, ricinoleic acid anions showed very poor tendency for inclusion either with high temperature or at long time which may be attributed to its chemical structure, which is too large for the CD cavities. Also, un-conjugated linoleic acid anions showed higher inclusion than the conjugated ones. MMT assay was used to determine the cyto- compatibility for the newly modified samples. Generally speaking, the highest fixation yields the highest cyto-compatibility of the treated samples. Iododeoxycellulose samples in both thermal and plasma curing reported high cyto-compatibility either with allylic ketone or azide derivative of linoleic acid over the other cellulose derivatives. Pure extracted fatty acids or included ones showed high cyto-compatibility towards L929 mouse cell line.

  2. Trace elemental composition of curry by inductively coupled plasma optical emission spectrometry (ICP-OES).

    PubMed

    Gonzálvez, A; Armenta, S; De La Guardia, M

    2008-01-01

    A methodology based on inductively coupled plasma optical emission spectrometry (ICP-OES) after microwave-assisted acid digestion was developed to determine the content of traces elements in curry samples from the Spanish market. The methodology was validated in terms of accuracy by the analysis of citrus and tomato leaf reference materials achieving comparable results with the certified values. The trace metal content of curry samples was compared with data available from previously published reports concerning Indian samples, especially in terms of heavy metal composition, in order to guarantee the quality of the commercially available spices in the European countries. Values found for the analysis of arsenic, lead and cadmium were significantly lower than the maximum limit allowed by European Union statutory limits for heavy metals and lower than those obtained for Indian curry leaves reported by Indian research teams by using neutron activation and γ-ray analysis.

  3. Use of laser ablation-inductively coupled plasma-time of flight-mass spectrometry to identify the elemental composition of vanilla and determine the geographic origin by discriminant function analysis.

    PubMed

    Hondrogiannis, Ellen M; Ehrlinger, Erin; Poplaski, Alyssa; Lisle, Meredith

    2013-11-27

    A total of 11 elements found in 25 vanilla samples from Uganda, Madagascar, Indonesia, and Papua New Guinea were measured by laser ablation-inductively coupled plasma-time-of-flight-mass spectrometry (LA-ICP-TOF-MS) for the purpose of collecting data that could be used to discriminate among the origins. Pellets were prepared of the samples, and elemental concentrations were obtained on the basis of external calibration curves created using five National Institute of Standards and Technology (NIST) standards and one Chinese standard with (13)C internal standardization. These curves were validated using NIST 1573a (tomato leaves) as a check standard. Discriminant analysis was used to successfully classify the vanilla samples by their origin. Our method illustrates the feasibility of using LA-ICP-TOF-MS with an external calibration curve for high-throughput screening of spice screening analysis.

  4. Laser Plasma Soft X-ray Microscope with Wolter Mirrors for Observation of Biological Specimens in Air

    NASA Astrophysics Data System (ADS)

    Hoshino, Masato; Aoki, Sadao

    2006-02-01

    A laser plasma soft X-ray microscope with Wolter mirrors was developed so that specimens could be set in the atmosphere. Silicon nitride membranes 100 nm thick were used as vacuum-tight windows. Using relatively large windows (0.46× 0.46 mm2), an adequate working distance for samples, which was approximately 1.2 mm, was assured. The endurance of the vacuum-tight window was measured briefly. Dry biological cells could be observed with resolution better than 100 nm. A preliminary observation of wet biological cells was carried out using a wet environmental sample holder which was composed of only two sheets of silicon nitride membrane. An X-ray micrograph of wet red blood cells from a chicken was obtained without apparent effects of radiation damage. The properties of a vacuum-tight window and a wet sample holder are discussed.

  5. Validation of a new point-of-care assay for determination of β-carotene concentration in bovine whole blood and plasma.

    PubMed

    Raila, Jens; Enjalbert, Francis; Mothes, Ralf; Hurtienne, Andrea; Schweigert, Florian J

    2012-03-01

    β-Carotene is an important precursor of vitamin A, and is associated with bovine fertility. β-Carotene concentrations in plasma are used to optimize β-carotene supplementation in cattle, but measurement requires specialized equipment to separate plasma and extract and measure β-carotene, either using spectrophotometry or high performance liquid chromatography (HPLC). The objective of this study was to validate a new 2-step point-of-care (POC) assay for measuring β-carotene in whole blood and plasma. β-carotene concentrations in plasma from 166 cows were measured using HPLC and compared with results obtained using a POC assay, the iCheck-iEx-Carotene test kit. Whole blood samples from 23 of these cattle were also evaluated using the POC assay and compared with HPLC-plasma results from the same 23 animals. The POC assay includes an extraction vial (iEx Carotene) and hand-held photometer (iCheck Carotene). Concentrations of β-carotene in plasma measured using the POC assay ranged from 0.40 to 15.84 mg/L (n = 166). No differences were observed between methods for assay of plasma (mean ± SD; n = 166): HPLC-plasma 4.23 ± 2.35 mg/L; POC-plasma 4.49 ± 2.36 mg/L. Similar good agreement was found when plasma analyzed using HPLC was compared with whole blood analyzed using the POC system (n = 23): HPLC-plasma 3.46 ± 2.12 mg/L; POC-whole blood 3.67 ± 2.29 mg/L. Concentrations of β-carotene can be measured in blood and plasma from cattle easily and rapidly using a POC assay, and results are comparable to those obtained by the highly sophisticated HPLC method. Immediate feedback regarding β-carotene deficiency facilitates rapid and appropriate optimization of β-carotene supplementation in feed. © 2012 American Society for Veterinary Clinical Pathology.

  6. Development and Validation of a Sensitive LC-MS/MS Method for the Determination of Fenoterol in Human Plasma and Urine Samples

    PubMed Central

    Sanghvi, M.; Ramamoorthy, A.; Strait, J.; Wainer, I. W.; Moaddel, R.

    2013-01-01

    Due to the lack of sensitivity in current methods for the determination of fenoterol (Fen). A rapid, LC-MS/MS method was developed for the determination of (R,R′)-Fen and (R,R′;S,S′)-Fen in plasma and urine. The method was fully validated and was linear from 50 pg/ml to 2000 pg/ml for plasma and from 2.500 ng/ml to 160 ng/ml for urine with a lower limit of quantitation of 52.8 pg/ml in plasma. The coefficient of variation was <15% for the high QC standards and <10% for the low QC standards in plasma and was <15% for the high and low QC standards in urine. The relative concentrations of (R,R′)-Fen and (S,S′)-Fen were determined using a chirobiotic T chiral stationary phase. The method was used to determine the concentration of (R,R′)-Fen in plasma and urine samples obtained in an oral cross-over study of (R,R′)-Fen and (R,R′;S,S′)-Fen formulations. The results demonstrated a potential pre-systemic enantioselective interaction in which the (S,S′)-Fen reduces the sulfation of the active (R,R′)-Fen. The data suggests that a non-racemic mixture of the Fen enantiomers may provide better bioavailability of the active (R,R′)-Fen for use in the treatment of cardiovascular disease PMID:23872161

  7. Energy metabolism in mobile, wild-sampled sharks inferred by plasma lipids.

    PubMed

    Gallagher, Austin J; Skubel, Rachel A; Pethybridge, Heidi R; Hammerschlag, Neil

    2017-01-01

    Evaluating how predators metabolize energy is increasingly useful for conservation physiology, as it can provide information on their current nutritional condition. However, obtaining metabolic information from mobile marine predators is inherently challenging owing to their relative rarity, cryptic nature and often wide-ranging underwater movements. Here, we investigate aspects of energy metabolism in four free-ranging shark species ( n  = 281; blacktip, bull, nurse, and tiger) by measuring three metabolic parameters [plasma triglycerides (TAG), free fatty acids (FFA) and cholesterol (CHOL)] via non-lethal biopsy sampling. Plasma TAG, FFA and total CHOL concentrations (in millimoles per litre) varied inter-specifically and with season, year, and shark length varied within a species. The TAG were highest in the plasma of less active species (nurse and tiger sharks), whereas FFA were highest among species with relatively high energetic demands (blacktip and bull sharks), and CHOL concentrations were highest in bull sharks. Although temporal patterns in all metabolites were varied among species, there appeared to be peaks in the spring and summer, with ratios of TAG/CHOL (a proxy for condition) in all species displaying a notable peak in summer. These results provide baseline information of energy metabolism in large sharks and are an important step in understanding how the metabolic parameters can be assessed through non-lethal sampling in the future. In particular, this study emphasizes the importance of accounting for intra-specific and temporal variability in sampling designs seeking to monitor the nutritional condition and metabolic responses of shark populations.

  8. Microfluidic point-of-care blood panel based on a novel technique: Reversible electroosmotic flow

    PubMed Central

    Mohammadi, Mahdi; Madadi, Hojjat; Casals-Terré, Jasmina

    2015-01-01

    A wide range of diseases and conditions are monitored or diagnosed from blood plasma, but the ability to analyze a whole blood sample with the requirements for a point-of-care device, such as robustness, user-friendliness, and simple handling, remains unmet. Microfluidics technology offers the possibility not only to work fresh thumb-pricked whole blood but also to maximize the amount of the obtained plasma from the initial sample and therefore the possibility to implement multiple tests in a single cartridge. The microfluidic design presented in this paper is a combination of cross-flow filtration with a reversible electroosmotic flow that prevents clogging at the filter entrance and maximizes the amount of separated plasma. The main advantage of this design is its efficiency, since from a small amount of sample (a single droplet ∼10 μl) almost 10% of this (approx 1 μl) is extracted and collected with high purity (more than 99%) in a reasonable time (5–8 min). To validate the quality and quantity of the separated plasma and to show its potential as a clinical tool, the microfluidic chip has been combined with lateral flow immunochromatography technology to perform a qualitative detection of the thyroid-stimulating hormone and a blood panel for measuring cardiac Troponin and Creatine Kinase MB. The results from the microfluidic system are comparable to previous commercial lateral flow assays that required more sample for implementing fewer tests. PMID:26396660

  9. Changing the surface properties on naval steel as result of non-thermal plasma treatment

    NASA Astrophysics Data System (ADS)

    Hnatiuc, B.; Sabău, A.; Dumitrache, C. L.; Hnatiuc, M.; Crețu, M.; Astanei, D.

    2016-08-01

    The problem of corrosion, related to Biofouling formation, is an issue with very high importance in the maritime domain. According to new rules, the paints and all the technologies for the conditioning of naval materials must fulfil more restrictive environmental conditions. In order to solve this issue, different new clean technologies have been proposed. Among them, the use of non-thermal plasmas produced at atmospheric pressure plays a very important role. This study concerns the opportunity of plasma treatment for preparation or conditioning of naval steel OL36 type. The plasma reactors chosen for the experiments can operate at atmospheric pressure and are easy to use in industrial conditions. They are based on electrical discharges GlidArc and Spark, which already proved their efficiency for the surface activation or even for coatings of the surface. The non-thermal character of the plasma is ensured by a gas flow blown through the electrical discharges. One power supply has been used for reactors that provide a 5 kV voltage and a maximum current of 100 mA. The modifications of the surface properties and composition have been studied by XPS technique (X-ray Photoelectron Spectroscopy). There were taken into consideration 5 samples: 4 of them undergoing a Mini-torch plasma, a Gliding Spark, a GlidArc with dry air and a GlidArc with CO2, respectively the fifth sample which is the untreated witness. Before the plasma treatment, samples of naval steel were processed in order to obtain mechanical gloss. The time of treatment was chosen to 12 minutes. In the spectroscopic analysis, done on a ULVAC-PHI, Inc. PHI 5000 Versa Probe scanning XPS microprobe, a monocromated Al Kα X-ray source with a spot size of 100 μm2 was used to scan each sample while the photoelectrons were collected at a 45-degree take-off angle. Differences were found between atomic concentrations in each individual case, which proves that the active species produced by each type of plasma affects the surface properties of the treated naval steel.

  10. Dispersive liquid-liquid microextraction followed by high-performance liquid chromatography-ultraviolet detection to determination of opium alkaloids in human plasma.

    PubMed

    Ahmadi-Jouibari, Toraj; Fattahi, Nazir; Shamsipur, Mojtaba; Pirsaheb, Meghdad

    2013-11-01

    A novel, simple, rapid and sensitive dispersive liquid-liquid microextraction method based on the solidification of floating organic drop (DLLME-SFO) combined with high-performance liquid chromatography-ultraviolet detection (HPLC-UV) was used to determine opium alkaloids in human plasma. During the extraction procedure, plasma protein was precipitated by using a mixture of zinc sulfate solution and acetonitrile. Some effective parameters on extraction were studied and optimized. Under the optimum conditions (extraction solvent: 30.0 μl 1-undecanol; disperser solvent: 470 μl acetone; pH: 9; salt addition: 1%(w/v) NaCl and extraction time: 0.5 min), calibration curves are linear in the range of 1.5-1000 μgl(-1) and limit of detections (LODs) are in the range of 0.5-5 μgl(-1). The relative standard deviations (RSDs) for 100 μgl(-1) of morphine and codeine, 10.0 μgl(-1) of papaverine and 20.0 μgl(-1) of noscapine in diluted human plasma are in the range of 4.3-7.4% (n=5). Finally, the method was successfully applied in the determination of opium alkaloids in the actual human plasma samples. The relative recoveries of plasma samples spiked with alkaloids are 88-110.5%. The obtained results show that DLLME-SFO combined with HPLC-UV is a fast and simple method for the determination of opium alkaloids in human plasma. Copyright © 2013 Elsevier B.V. All rights reserved.

  11. Comparison of a high temperature torch integrated sample introduction system with a desolvation system for the analysis of microsamples through inductively coupled plasma mass spectrometry

    NASA Astrophysics Data System (ADS)

    Sánchez, Raquel; Cañabate, Águeda; Bresson, Carole; Chartier, Frédéric; Isnard, Hélène; Maestre, Salvador; Nonell, Anthony; Todolí, José-Luis

    2017-03-01

    This work describes for the first time the comparison of the analytical performances obtained with a high temperature torch integrated sample introduction system (hTISIS) against those found with a commercially available desolvation system (APEX) associated with inductively coupled plasma mass spectrometry (ICP-MS). A double pass spray chamber was taken as the reference system. Similar detection limits and sensitivities were obtained in continuous injection mode at low liquid flow rates for the APEX and hTISIS operating at high temperatures. In contrast, in the air-segmented injection mode, the detection limits obtained with hTISIS at high temperatures were up to 12 times lower than those found for the APEX. Regarding memory effects, wash out times were shorter in continuous mode and peaks were narrower in air segmented mode for the hTISIS as compared to the APEX. Non spectral interferences (matrix effects) were studied with 10% nitric acid, 2% methanol, for an ICP multielemental solution and a hydro-organic matrix containing 70% (v/v) acetonitrile in water, 15 mmol L- 1 ammonium acetate and 0.5% formic acid containing lanthanide complexes. In all the cases, matrix effects were less severe for the hTISIS operating at 200 °C and the APEX than for the double pass spray chamber. Finally, two spiked reference materials (sea water and Antartic krill) were analyzed. The hTISIS operating at 200 °C gave the best results compared to those obtained with the APEX and the double pass spray chamber. In conclusion, despite the simplicity of the hTISIS, it provided, at low liquid flow rates, results similar to or better than those obtained with the by other sample introduction systems.

  12. Multiplex picoliter-droplet digital PCR for quantitative assessment of EGFR mutations in circulating cell-free DNA derived from advanced non-small cell lung cancer patients.

    PubMed

    Yu, Qian; Huang, Fei; Zhang, Meilin; Ji, Haiying; Wu, Shenchao; Zhao, Ying; Zhang, Chunyan; Wu, Jiong; Wang, Beili; Pan, Baisheng; Zhang, Xin; Guo, Wei

    2017-08-01

    To explore the possible diagnostic value of liquid biopsy, two multiplex panels using picoliter-droplet digital polymerase chain reaction (ddPCR) were established to quantitatively assess the epidermal growth factor receptor (EGFR) mutations in cell‑free DNA (cfDNA) extracted from the plasma of advanced non‑small cell lung cancer (NSCLC) patients. Plasma samples derived from 22 patients with stage IIIB/IV NSCLC harboring EGFR mutations in matched tumor tissues confirmed by amplification refractory mutation system (ARMS) analysis were subjected to two multiplex ddPCR panels to assess the abundance of tyrosine kinase inhibitor (TKI) ‑sensitive (19DEL, L858R) and TKI‑resistant (T790 M) mutations. Fluctuations in EGFR mutant abundance were monitored by either of the multiplex ddPCR panels for three patients undergoing EGFR‑TKI treatment, with serial plasma sample collections over 2 months. The multiplex ddPCR panels applied to plasma cfDNA from advanced NSCLC patients achieved a total concordance rate of 80% with the EGFR mutation profiles obtained by ARMS from matched biopsy tumor specimens (90% for 19DEL, 95% for L858R, 95% for T790M, respectively) and revealed additional mutant alleles in two subjects. The respective sensitivity and specificity were 90.9 and 88.9% for 19DEL, 87.5 and 100% for L858R, 100 and 93.8% for T790M. The fluctuations of EGFR mutant abundance in serial plasma cfDNA were in accordance with the changes in tumor size as assessed by imaging scans. The authors demonstrated the utility of multiplex ddPCR panels with ultra‑sensitivity for quantitative analysis of EGFR mutations in plasma cfDNA and obtained promising usefulness in EGFR‑TKI decision‑making for advanced NSCLC patients.

  13. Multiplex picoliter-droplet digital PCR for quantitative assessment of EGFR mutations in circulating cell-free DNA derived from advanced non-small cell lung cancer patients

    PubMed Central

    Yu, Qian; Huang, Fei; Zhang, Meilin; Ji, Haiying; Wu, Shenchao; Zhao, Ying; Zhang, Chunyan; Wu, Jiong; Wang, Beili; Pan, Baisheng; Zhang, Xin; Guo, Wei

    2017-01-01

    To explore the possible diagnostic value of liquid biopsy, two multiplex panels using picoliter-droplet digital polymerase chain reaction (ddPCR) were established to quantitatively assess the epidermal growth factor receptor (EGFR) mutations in cell-free DNA (cfDNA) extracted from the plasma of advanced non-small cell lung cancer (NSCLC) patients. Plasma samples derived from 22 patients with stage IIIB/IV NSCLC harboring EGFR mutations in matched tumor tissues confirmed by amplification refractory mutation system (ARMS) analysis were subjected to two multiplex ddPCR panels to assess the abundance of tyrosine kinase inhibitor (TKI) -sensitive (19DEL, L858R) and TKI-resistant (T790 M) mutations. Fluctuations in EGFR mutant abundance were monitored by either of the multiplex ddPCR panels for three patients undergoing EGFR-TKI treatment, with serial plasma sample collections over 2 months. The multiplex ddPCR panels applied to plasma cfDNA from advanced NSCLC patients achieved a total concordance rate of 80% with the EGFR mutation profiles obtained by ARMS from matched biopsy tumor specimens (90% for 19DEL, 95% for L858R, 95% for T790M, respectively) and revealed additional mutant alleles in two subjects. The respective sensitivity and specificity were 90.9 and 88.9% for 19DEL, 87.5 and 100% for L858R, 100 and 93.8% for T790M. The fluctuations of EGFR mutant abundance in serial plasma cfDNA were in accordance with the changes in tumor size as assessed by imaging scans. The authors demonstrated the utility of multiplex ddPCR panels with ultra-sensitivity for quantitative analysis of EGFR mutations in plasma cfDNA and obtained promising usefulness in EGFR-TKI decision-making for advanced NSCLC patients. PMID:29067441

  14. Surface improvement of EPDM rubber by plasma treatment

    NASA Astrophysics Data System (ADS)

    Moraes, J. H.; da Silva Sobrinho, A. S.; Maciel, H. S.; Dutra, J. C. N.; Massi, M.; Mello, S. A. C.; Schreiner, W. H.

    2007-12-01

    The surface of ethylene-propylene-diene monomer (EPDM) rubber was treated in N2/Ar and N2/H2/Ar RF plasmas in order to achieve similar or better adhesion properties than NBR (acrylonitrile-butadiene) rubber, nowadays used as thermal protection of rocket chambers. The surface properties were studied by contact angle measurements and by x-ray photoelectron spectroscopy (XPS). The treated surfaces of the EPDM samples show a significant reduction in the contact angle measurement, indicating an increase in the surface energy. XPS analyses show the incorporation of polar nitrogen- and oxygen-containing groups on the rubber surface. After plasma treatment the presence of oxygen is observed due to surface oxidation which occurs when the samples are exposed to the air. Atomic force microscopy and scanning electron microscopy analyses indicate a decrease in the EPDM rubber surface roughness, promoted by surface etching during the plasma treatment. Strength tests indicate improvement of about 30% and 110% in the adhesion strength for the plasma treated EPDM/polyurethane liner interface and for the EPDM/epoxy adhesive interface, respectively. The adhesion strength of the EPDM/liner is similar to that obtained for the NBR/liner, which indicates that EPDM rubber can safely be used as thermal protection of the solid propellant rocket chamber.

  15. Solute removal capacity of high cut-off membrane plasma separators.

    PubMed

    Ohkubo, Atsushi; Kurashima, Naoki; Nakamura, Ayako; Miyamoto, Satoko; Iimori, Soichiro; Rai, Tatemitsu

    2013-10-01

    In vitro blood filtration was performed by a closed circuit using high cut-off membrane plasma separators, EVACURE EC-2A10 (EC-2A) and EVACURE EC-4A10 (EC-4A). Samples were obtained from sampling sites before the plasma separator, after each plasma separator, and from the ultrafiltrate of each separator. The sieving coefficient (S.C.) of total protein (TP), albumin (Alb), IgG, interleukin-6 (IL-6), interleukin-8 (IL-8), tumor necrosis factor-α (TNF-α), fibrinogen (Fib), antithrombin III (AT-III), and coagulation factor XIII (FXIII) were calculated. The S.C. of each solute using EC-2A and EC-A4 were as follows; TP: 0.25 and 0.56, Alb: 0.32 and 0.73, IgG: 0.16 and 0.50, IL-6:0.73 and 0.95, IL-8:0.85 and 0.82, TNF-α: 1.07 and 0.99, Fib: 0 and 0, FXIII: 0.07 and 0.17, respectively. When compared with the conventional type of membrane plasma separators, EVACURE could efficiently remove cytokines while retaining coagulation factors such as fibrinogen. Moreover, EC-2A prevented protein loss, whereas EC-4A could remove approximately 50% of IgG. © 2013 The Authors. Therapeutic Apheresis and Dialysis © 2013 International Society for Apheresis.

  16. On the improvement of signal repeatability in laser-induced air plasmas

    NASA Astrophysics Data System (ADS)

    Zhang, Shuai; Sheta, Sahar; Hou, Zong-Yu; Wang, Zhe

    2018-04-01

    The relatively low repeatability of laser-induced breakdown spectroscopy (LIBS) severely hinders its wide commercialization. In the present work, we investigate the optimization of LIBS system for repeatability improvement for both signal generation (plasma evolution) and signal collection. Timeintegrated spectra and images were obtained under different laser energies and focal lengths to investigate the optimum configuration for stable plasmas and repeatable signals. Using our experimental setup, the optimum conditions were found to be a laser energy of 250 mJ and a focus length of 100 mm. A stable and homogeneous plasma with the largest hot core area in the optimum condition yielded the most stable LIBS signal. Time-resolved images showed that the rebounding processes through the air plasma evolution caused the relative standard deviation (RSD) to increase with laser energies of > 250 mJ. In addition, the emission collection was improved by using a concave spherical mirror. The line intensities doubled as their RSDs decreased by approximately 25%. When the signal generation and collection were optimized simultaneously, the pulse-to-pulse RSDs were reduced to approximately 3% for O(I), N(I), and H(I) lines, which are better than the RSDs reported for solid samples and showed great potential for LIBS quantitative analysis by gasifying the solid or liquid samples.

  17. Synthesis of antibacterial surfaces by plasma grafting of zinc oxide based nanocomposites onto polypropylene.

    PubMed

    de Rancourt, Yoann; Couturaud, Benoit; Mas, André; Robin, Jean Jacques

    2013-07-15

    Antibacterial polymer surfaces were designed using ZnO nanoparticles as a bactericide. Mineral encapsulated nanoparticles were grafted onto activated polymer surfaces through their shells. Polypropylene (PP) surfaces were treated using an innovative process coupling core-shell technology and plasma grafting, well-known techniques commonly used to obtain active surfaces for biomedical applications. First, ZnO nanoparticles were encapsulated by (co)polymers: poly(acrylic acid) (PAA) or a poly(methyl methacrylate-co-methacrylic acid) copolymer [P(MMA-MA)]. Second, PP substrates were activated using plasma treatment. Finally, plasma-treated surfaces were immersed in solutions containing the encapsulated nanoparticles dispersed in an organic solvent and allowed to graft onto it. The presence of nanoparticles on the substrates was demonstrated using Fourier-Transform Infrared Spectroscopy (FTIR) analysis, Scanning Electron Microspcopy (SEM)/Energy-Dispersive X-ray (EDX), and Atomic Force Microscopy (AFM) studies. Indeed, the ZnO-functionalized substrates exhibited an antibacterial response in Escherichia coli adhesion tests. Moreover, this study revealed that, surprisingly, native ZnO nanoparticles without any previous functionalization could be directly grafted onto polymeric surfaces through plasma activation. The antibacterial activity of the resulting sample was shown to be comparable to that of the other samples. Copyright © 2013 Elsevier Inc. All rights reserved.

  18. Insights into accelerated liposomal release of topotecan in plasma monitored by a non-invasive fluorescence spectroscopic method

    PubMed Central

    Fugit, Kyle D.; Jyoti, Amar; Upreti, Meenakshi; Anderson, Bradley D.

    2014-01-01

    A non-invasive fluorescence method was developed to monitor liposomal release kinetics of the anticancer agent topotecan (TPT) in physiological fluids and subsequently used to explore the cause of accelerated release in plasma. Analyses of fluorescence excitation spectra confirmed that unencapsulated TPT exhibits a red shift in its spectrum as pH is increased. This property was used to monitor TPT release from actively loaded liposomal formulations having a low intravesicular pH. Mathematical release models were developed to extract reliable rate constants for TPT release in aqueous solutions monitored by fluorescence and release kinetics obtained by HPLC. Using the fluorescence method, accelerated TPT release was observed in plasma as previously reported in the literature. Simulations to estimate the intravesicular pH were conducted to demonstrate that accelerated release correlated with alterations in the low intravesicular pH. This was attributed to the presence of ammonia in plasma samples rather than proteins and other plasma components generally believed to alter release kinetics in physiological samples. These findings shed light on the critical role that ammonia may play in contributing to the preclinical/clinical variability and performance seen with actively-loaded liposomal formulations of TPT and other weakly-basic anticancer agents. PMID:25456833

  19. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Swarup, S.; Chatterjea, J.B.; Hosain, P.

    Several Hb. E-thalassemia and a few other cases of hematological interest were subjected to radio-iron tests using tracer doses of only 0.035 plus or minus 0.005 mu c/kg. of bodyweight and gas-flow counter for assaying the radio-activity of the samples. Serum iron and hemoglobin iron concentrations; curves for plasma iron clearance and appearance of radio-iron in red cells, and the plasma iron and the red cell iron turnover rates were obtained by standard methods. The results showed an increased rate of plasma clearance but decreased utilization of iron by erythrocytes in Hb. E-thalassemia disease; plasma iron-clearance pattern was similar tomore » iron deficiency anemia but the red cell radio-iron uptake pattern bore similarity to aplastic anemia. This suggests that ineffective erythropoiesis contributes significantly to the causation of anemia in Hb. E-thalassemia disease. (auth)« less

  20. Modeling of high-Z materials erosion and its suppression in DIII-D

    NASA Astrophysics Data System (ADS)

    Ding, Rui; Guo, H. Y.; Chan, V. S.; Snyder, P. B.; Rudakov, D. L.; Stangeby, P. C.; Elder, J. D.; Tskhakaya, D.; Wampler, W. R.; Kirschner, A.; McLean, A. G.

    2015-11-01

    Erosion of plasma facing components is a key issue for high-power, long pulse operation. The 3D Monte Carlo code ERO has been used to simulate the erosion/redeposition of Mo and W samples exposed to DIII-D divertor plasma using the DiMES. The net erosion rate is significantly reduced due to the high local re-deposition ratio of eroded materials, which is mainly controlled by the electric field and plasma density within the Chodura sheath as indicated by ERO modeling. Similar re-deposition ratios were obtained from the modeling using three sheath models for small inclined magnetic field angle, all being close to the measured value. ERO modeling shows that local CH4 injection can create a carbon coating on the Mo sample to mitigate Mo erosion; the local decrease of electron temperature due to gas injection also suppresses net erosion, consistent with experimental observation. Supported by the US DOE under DE-FC02-04ER54698 and PSI-SciDAC project.

  1. Minimally-invasive Laser Ablation Inductively Coupled Plasma Mass Spectrometry analysis of model ancient copper alloys

    NASA Astrophysics Data System (ADS)

    Walaszek, Damian; Senn, Marianne; Wichser, Adrian; Faller, Markus; Wagner, Barbara; Bulska, Ewa; Ulrich, Andrea

    2014-09-01

    This work describes an evaluation of a strategy for multi-elemental analysis of typical ancient bronzes (copper, lead bronze and tin bronze) by means of laser ablation inductively coupled plasma mass spectrometry (LA-ICPMS).The samples originating from archeological experiments on ancient metal smelting processes using direct reduction in a ‘bloomery’ furnace as well as historical casting techniques were investigated with the use of the previously proposed analytical procedure, including metallurgical observation and preliminary visual estimation of the homogeneity of the samples. The results of LA-ICPMS analysis were compared to the results of bulk composition obtained by X-ray fluorescence spectrometry (XRF) and by inductively coupled plasma mass spectrometry (ICPMS) after acid digestion. These results were coherent for most of the elements confirming the usefulness of the proposed analytical procedure, however the reliability of the quantitative information about the content of the most heterogeneously distributed elements was also discussed in more detail.

  2. Relationship between chronic lead toxicity and plasma neurotransmitters in autistic patients from Saudi Arabia.

    PubMed

    El-Ansary, Afaf K; Bacha, Abir Ben; Ayahdi, Layla Y Al-

    2011-09-01

    This study aims to clarify the relationship between blood Pb(2+) concentration as a ubiquitous environmental pollutant and plasma neurotransmitters as biochemical parameters that reflect brain function in Saudi autistic patients. RBC's lead content together with plasma concentration of gamma aminobutyric acid (GABA), serotonin (5HT) and dopamine (DA) were measured in 25 Saudi autistic patients and compared to 16 age-matching control samples. The obtained data recorded that Saudi autistic patients have a remarkable higher levels of Pb(2+) and significantly elevated levels of GABA, 5HT and DA compared to healthy subjects. ROC analysis revealed satisfactory values of specificity and sensitivity of the measured parameters. This study suggests that postnatal lead toxicity in autistic patients of Saudi Arabia could represent a causative factor in the pathogenesis of autism. Elevated GABA, 5HT and DA were discussed in relation to the chronic lead toxicity recorded in the investigated autistic samples. Copyright © 2011. Published by Elsevier Inc.

  3. Plasma Glucose Levels for Red Drum Sciaenops Ocellatus in a Florida Estuarine Fisheries Reserve

    NASA Technical Reports Server (NTRS)

    Bourtis, Carla M.; Francis-Floyd, Ruth; Boggs, Ashley S P.; Reyier, Eric A.; Stolen, Eric D.; Yanong, Roy P.; Guillette, Louis J., Jr.

    2015-01-01

    Despite the significant value of the southeastern United States' red drum (Sciaenops ocellatus) fishery, there is a lack of clinical blood chemistry data. This was the first study to assess plasma glucose values as an indicator of stress response to evaluate variation and the effect of reproductive activity for wild adult red drum in Florida. Red drum (n=126) were collected from NASA's Kennedy Space Center waters during three reproductive periods in 2011. Samples were obtained from the branchial vessels of the gill arch. Plasma glucose levels were significantly different among reproductive periods, with the highest mean values recorded during the spawning period, September- October (38.23 mg / dL +/- 10.0). The glucose range was 17 - 69 mg / dL. Glucose values were lower during all three periods than previous values recorded for cultured or captive red drum studies. This may indicate that fish from this population were under less stress than other populations previously sampled.

  4. High Precision Isotopic Analysis of Actinide Bearing Materials: Performance of a New Generation of Purpose Built Actinide Multi-Collector ICPMS Instruments

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Eiden, Gregory C.; Duffin, Andrew M.; Liezers, Martin

    2014-11-14

    Recently, a new class of multi-collector inductively coupled plasma mass spectrometers (MC-ICPMS) has been introduced commercially that includes detector arrays purpose built for actinide measurements. These detector arrays significantly enhance the data quality possible for applications encountered in nuclear forensics. Two such instruments are described in this paper, the NeptunePlusTM, developed by Thermo-Fisher (Bremen, Germany), and the NuPlasma2, developed by Nu Instruments (Wrexham, UK). Research results are presented that have been obtained by the authors using the first commercial NeptunePlusTM. This paper also presents performance characteristics and results for traditional liquid introduction, including a means for ultra-trace detection via electrochemicalmore » separation prior to solution nebulization, as well as solid sample introduction with femtosecond-laser ablation. We also discuss the advantages and limitations of the current systems for detection of the transient signals associated with these two methods for introducing sample into the plasma.« less

  5. Second-order Kinetics of DTPA and Plutonium in Rat Plasma

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Miller, Guthrie; Poudel, Deepesh; Klumpp, John Allan

    We report that in 2008, Serandour et al. reported on their in vitro experiment involving rat plasma samples obtained after an intravenous intake of plutonium citrate. Different amounts of DTPA were added to the plasma samples and the percentage of low-molecular-weight plutonium measured. Only when the DTPA dosage was three orders of magnitude greater than the recommended 30 μmol/kg was 100% of the plutonium apparently in the form of chelate. These data were modeled assuming three competing chemical reactions with other molecules that bind with plutonium. Here, time-dependent second-order kinetics of these reactions are calculated, intended eventually to become partmore » of a complete biokinetic model of DTPA action on actinides in laboratory animals or humans. The probability distribution of the ratio of stability constants for the reactants was calculated using Markov Chain Monte Carlo. In conclusion, these calculations substantiate that the inclusion of more reactions is needed in order to be in agreement with known stability constants.« less

  6. Profiling of patterned metal layers by laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS)

    NASA Astrophysics Data System (ADS)

    Bi, Melody; Ruiz, Antonio M.; Gornushkin, Igor; Smith, Ben W.; Winefordner, James D.

    2000-02-01

    Laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) was used for profiling patterned thin metal layers on a polymer/silicon substrate. The parameters of the laser and ICP-MS operating conditions have been studied and optimized for this purpose. A new laser ablation chamber was designed and built to achieve the best spatial resolution. The results of the profiling by LA-ICP-MS were compared to those obtained from a laser ablation optical emission spectrometry (LA-OES) instrument, which measured the emission of the plasma at the sample surface, and thus, eliminated the time delay caused by the sample transport into the ICP-MS system. Emission spectra gave better spatial resolution than mass spectra. However, LA-ICP-MS provided much better sensitivity and was able to profile thin metal layers (on the order of a few nanometers) on the silicon surface. A lateral spatial resolution of 45 μm was achieved.

  7. Second-order Kinetics of DTPA and Plutonium in Rat Plasma

    DOE PAGES

    Miller, Guthrie; Poudel, Deepesh; Klumpp, John Allan; ...

    2017-11-15

    We report that in 2008, Serandour et al. reported on their in vitro experiment involving rat plasma samples obtained after an intravenous intake of plutonium citrate. Different amounts of DTPA were added to the plasma samples and the percentage of low-molecular-weight plutonium measured. Only when the DTPA dosage was three orders of magnitude greater than the recommended 30 μmol/kg was 100% of the plutonium apparently in the form of chelate. These data were modeled assuming three competing chemical reactions with other molecules that bind with plutonium. Here, time-dependent second-order kinetics of these reactions are calculated, intended eventually to become partmore » of a complete biokinetic model of DTPA action on actinides in laboratory animals or humans. The probability distribution of the ratio of stability constants for the reactants was calculated using Markov Chain Monte Carlo. In conclusion, these calculations substantiate that the inclusion of more reactions is needed in order to be in agreement with known stability constants.« less

  8. Application of Plackett-Burman and Doehlert designs for optimization of selenium analysis in plasma with electrothermal atomic absorption spectrometry.

    PubMed

    El Ati-Hellal, Myriam; Hellal, Fayçal; Hedhili, Abderrazek

    2014-10-01

    The aim of this study was the optimization of selenium determination in plasma samples with electrothermal atomic absorption spectrometry using experimental design methodology. 11 variables being able to influence selenium analysis in human blood plasma by electrothermal atomic absorption spectrometry (ETAAS) were evaluated with Plackett-Burman experimental design. These factors were selected from sample preparation, furnace program and chemical modification steps. Both absorbance and background signals were chosen as responses in the screening approach. Doehlert design was used for method optimization. Results showed that only ashing temperature has a statistically significant effect on the selected responses. Optimization with Doehlert design allowed the development of a reliable method for selenium analysis with ETAAS. Samples were diluted 1/10 with 0.05% (v/v) TritonX-100+2.5% (v/v) HNO3 solution. Optimized ashing and atomization temperatures for nickel modifier were 1070°C and 2270°C, respectively. A detection limit of 2.1μgL(-1) Se was obtained. Accuracy of the method was checked by the analysis of selenium in Seronorm™ Trace element quality control serum level 1. The developed procedure was applied for the analysis of total selenium in fifteen plasma samples with standard addition method. Concentrations ranged between 24.4 and 64.6μgL(-1), with a mean of 42.6±4.9μgL(-1). The use of experimental designs allowed the development of a cheap and accurate method for selenium analysis in plasma that could be applied routinely in clinical laboratories. Copyright © 2014 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  9. Development of water-phase derivatization followed by solid-phase microextraction and gas chromatography/mass spectrometry for fast determination of valproic acid in human plasma.

    PubMed

    Deng, Chunhui; Li, Ning; Ji, Jie; Yang, Bei; Duan, Gengli; Zhang, Xiangmin

    2006-01-01

    In this study, a simple, rapid, and sensitive method was developed and validated for the quantification of valproic acid (VPA), an antiepileptic drug, in human plasma, which was based on water-phase derivatization followed by headspace solid-phase microextraction (HS-SPME) and gas chromatography/mass spectrometry (GC/MS). In the proposed method, VPA in plasma was rapidly derivatized with a mixture of isobutyl chloroformate, ethanol and pyridine under mild conditions (room temperature, aqueous medium), and the VPA ethyl ester formed was headspace-extracted and simultaneously concentrated using the SPME technique. Finally, the analyte extracted on SPME fiber was analyzed by GC/MS. The experimental parameters and method validations were studied. The optimal conditions were obtained: PDMS fiber, stirring rate of 1100 rpm, sample temperature of 80 degrees C, extraction time of 20 min, NaCl concentration of 30%. The proposed method had a limit of quantification (0.3 microg/mL), good recovery (89-97%) and precision (RSD value less than 10%). Because the proposed method combined a rapid water-phase derivatization with a fast, simple and solvent-free sample extraction and concentration technique of SPME, the sample preparation time was less than 25 min. This much shortens the whole analysis time of VPA in plasma. The validated method has been successfully used to analyze VPA in human plasma samples for application in pharmacokinetic studies. All these results show that water-phase derivatization followed by HS-SPME and GC/MS is an alternative and powerful method for fast determination of VPA in biological fluids. Copyright 2006 John Wiley & Sons, Ltd.

  10. Plasma disposition and faecal excretion of oxfendazole, fenbendazole and albendazole following oral administration to donkeys.

    PubMed

    Gokbulut, Cengiz; Akar, Ferda; McKellar, Quintin A

    2006-07-01

    Fenbendazole (FBZ), oxfendazole (fenbendazole sulphoxide, FBZSO), and albendazole (ABZ) were administered orally to donkeys at 10mg/kg bodyweight. Blood and faecal samples were collected from 1 to 120 h post-treatment. The plasma and faecal samples were analysed by high performance liquid chromatography (HPLC). The parent molecule and its sulphoxide and sulphone (FBZSO(2)) metabolites did not reach detectable concentrations in any plasma samples following FBZ administration. ABZ was also not detected in any plasma samples, but its sulphoxide and sulphone metabolites were detected, demonstrating that ABZ was completely metabolised by first-pass mechanisms in donkeys. Maximum plasma concentrations (C(max)) of FBZSO (0.49microg/mL) and FBZSO(2) (0.60microg/mL) were detected at (t(max)) 5.67 and 8.00h, respectively, following administration of FBZSO. The area under the curve (AUC) of the sulphone metabolite (10.33microg h/mL) was significantly higher than that of the parent drug FBZSO (5.17microg h/mL). C(max) of albendazole sulphoxide (ABZSO) (0.08g/mL) and albendazole sulphone (ABZSO(2)) (0.04microg/mL) were obtained at 5.71 and 8.00h, respectively, following ABZ administration. The AUC of the sulphoxide metabolite (0.84microg h/mL) of ABZ was significantly higher than that of the sulphone metabolite (0.50microg h/mL). The highest dry-faecal concentrations of parent molecules were detected at 32, 34 and 30h for FBZSO, FBZ and ABZ, respectively. The sulphide metabolite was significantly higher than the parent molecule after FBZSO administration. The parent molecule was predominant in the faecal samples following FBZ administration. After ABZ administration, the parent molecule was significantly metabolised, probably by gastrointestinal microflora, to its sulphoxide metabolite (ABZSO) that showed a similar excretion profile to the parent molecule in the faecal samples. The AUC of the parent FBZ was significantly higher than that of FBZSO and ABZ in faeces. It is concluded that the plasma concentration of FBZSO was significantly higher than that of FBZ and ABZ. Although ABZ is not licensed for use in Equidae, its metabolites presented a greater plasma kinetic profile than FBZ which is licensed for use in horses. A higher metabolic capacity, first-pass effects and lower absorption of benzimidazoles in donkeys decrease bioavailability and efficacy compared to ruminants.

  11. High purity polyimide analysis by solid sampling graphite furnace atomic absorption spectrometry

    NASA Astrophysics Data System (ADS)

    Santos, Rafael F.; Carvalho, Gabriel S.; Duarte, Fabio A.; Bolzan, Rodrigo C.; Flores, Erico M. M.

    2017-03-01

    In this work, Cr, Cu, Mn, Na and Ni were determined in high purity polyimides (99.5%) by solid sampling graphite furnace atomic absorption spectrometry (SS-GFAAS) using Zeeman effect background correction system with variable magnetic field, making possible the simultaneous measurement at high or low sensitivity. The following analytical parameters were evaluated: pyrolysis and atomization temperatures, feasibility of calibration with aqueous solution, linear calibration range, sample mass range and the use of chemical modifier. Calibration with aqueous standard solutions was feasible for all analytes. No under or overestimated results were observed and up to 10 mg sample could be introduced on the platform for the determination of Cr, Cu, Mn, Na and Ni. The relative standard deviation ranged from 3 to 20%. The limits of detection (LODs) achieved using the high sensitivity mode were as low as 7.0, 2.5, 1.7, 17 and 0.12 ng g- 1 for Cr, Cu, Mn, Na and Ni, respectively. No addition of chemical modifier was necessary, except for Mn determination where Pd was required. The accuracy was evaluated by analyte spike and by comparison of the results with those obtained by inductively coupled plasma optical emission spectrometry and inductively coupled plasma mass spectrometry after microwave-assisted digestion in a single reaction chamber system and also by neutron activation analysis. No difference among the results obtained by SS-GFAAS and those obtained by alternative analytical methods using independent techniques. SS-GFAAS method showed some advantages, such as the determination of metallic contaminants in high purity polyimides with practically no sample preparation, very low LODs, calibration with aqueous standards and determination in a wide range of concentration.

  12. In–Depth Characterization of Viral Isolates from Plasma and Cells Compared with Plasma Circulating Quasispecies in Early HIV-1 Infection

    PubMed Central

    Erkizia, Itziar; Pino, Maria; Pou, Christian; Paredes, Roger; Clotet, Bonaventura; Martinez-Picado, Javier; Prado, Julia G.

    2012-01-01

    Background The use of in vitro models to unravel the phenotypic characteristics of circulating viral variants is key to understanding HIV-1 pathogenesis but limited by the availability of primary viral isolates from biological samples. However, overall in vivo genetic variability of HIV-1 within a subject may not be reflected in the viable viral population obtained after isolation. Although several studies have tried to determine whether viral populations expanded in vitro are representative of in vivo findings, the answer remains unclear due to the reduced number of clonal sequences analyzed or samples compared. In order to overcome previous experimental limitations, here we applied Deep Pyrosequencing (DPS) technology in combination with phenotypic experiments to analyze and compare with unprecedented detail the composition of viral isolates and in vivo quasispecies. Methodology/Principal Findings We amplified by DPS HIV-1 genomic regions covering gag, protease, integrase and env-V3 to characterize paired isolates from plasma and peripheral blood mononuclear cells and compare them with total plasma viral RNA in four recently HIV-1 infected subjects. Our study demonstrated the presence of unique haplotypes scattered between sample types with conservation of major variants. In addition, no differences in intra- and inter-population encoded protein variability were found between the different types of isolates or when these were compared to plasma viral RNA within subjects. Additionally, in vitro experiments demonstrated phenotypic similarities in terms of replicative capacity and co-receptor usage between viral isolates and plasma viral RNA. Conclusion This study is the first in-depth comparison and characterization of viral isolates from different sources and plasma circulating quasispecies using DPS in recently HIV-1 infected subjects. Our data supports the use of primary isolates regardless of their plasma or cellular origin to define genetic variability and biological traits of circulating HIV-1 quasispecies. PMID:22393441

  13. Comparison of Cannabinoid Concentrations in Plasma, Oral Fluid and Urine in Occasional Cannabis Smokers After Smoking Cannabis Cigarette.

    PubMed

    Marsot, Amélie; Audebert, Christine; Attolini, Laurence; Lacarelle, Bruno; Micallef, Joelle; Blin, Olivier

    A randomized cross-over, double blind placebo controlled study of smoked cannabis was carried out on occasional cannabis smokers. The objective of this research was to describe the pharmacokinetic parameters of THC and its metabolites in plasma, oral fluid and urine, from samples obtained simultaneously to provide estimations of THC and metabolites concentrations after smoking a cannabis cigarette. Blood, oral fluid and urine samples were collected until up to 72 h after smoking the cannabis cigarette (4% of delta-9-tetrathydrocannabinol (THC)). THC, 11-OH-THC and THC-COOH were analyzed by gas-chromatography-mass spectrometry. Pharmacokinetic parameters were estimated from these data. Eighteen male healthy adults participated in the study. In total, 560 plasma, 288 oral fluid and 448 urine samples were quantified for cannabinoids. Plasma, oral fluid and urine pharmacokinetic parameters were calculated. A wide range of median THC Cmax (1.6-160.0 µg/L and 55.4-123120.0 µg/L in plasma and oral fluid, respectively), 11-OH-THC Cmax (0-11.1 µg/L in plasma) and THC-COOH Cmax (1.0-56.3 µg/L in plasma) was observed. When expressed as a percentage of the total available THC dose, and corrected for molar equivalents, mean percentage of total THC dose excreted was 1.9 +/-2.5 % with range of 0.2-7.5%. This high inter-individual variability was also observed on other calculated pharmacokinetic parameters. Prediction of plasma THC concentration from THC oral fluid concentration or from THC-COOH urinary concentrations is not feasible due to the large variations observed. The results from this study support the assumption that a positive oral fluid THC result or a positive urine fluid result are indicative of a recent cannabis exposure. This article is open to POST-PUBLICATION REVIEW. Registered readers (see "For Readers") may comment by clicking on ABSTRACT on the issue's contents page.

  14. Cerebrospinal fluid and plasma C-reactive protein and aggression in personality-disordered subjects: a pilot study.

    PubMed

    Coccaro, Emil F; Lee, Royce; Coussons-Read, Mary

    2015-02-01

    C-reactive protein (CRP), in the plasma, serves as a marker of systemic inflammation and has been shown to correlate with history of actual aggressive behavior, and as a personality trait of aggressive tendency, in human subjects. This pilot study was conducted to determine if plasma CRP levels are correlated with cerebrospinal fluid levels (CSF CRP) and if CSF CRP also correlates with aggression. If so, this would suggest a role for central inflammatory processes in human aggression. Both plasma and basal lumbar CSF samples were obtained from 17 subjects with DSM-5 personality disorder and assayed for CRP. Plasma and CSF CRP levels were correlated (r = 0.65, p = 0.005) and each correlated with aggression (Plasma: r = 0.53, p = 0.029; CSF: r = 0.84, p < 0.001). When considered simultaneously, CSF CRP, but not plasma CRP, uniquely correlated with aggression. No relationship was seen with other measures of psychopathology. These data suggest a positive relationship between central nervous system CRP and aggression in humans.

  15. Stereospecific analysis of loxoprofen in plasma by chiral column liquid chromatography with a circular dichroism-based detector.

    PubMed

    Kanazawa, Hideko; Tsubayashi, Akane; Nagata, Yoshiko; Matsushima, Yoshikazu; Mori, Chiharu; Kizu, Junko; Higaki, Megumu

    2002-03-01

    The chiral separation of loxoprofen was achieved on a chiral column with UV and circular dichroism (CD) detection. The good resolution of four loxoprofen stereoisomers was obtained. The column used for the chiral separation was Chiralcel OJ column (250 x 4.6 mm) using hexane-2-propanol-trifluoroacetic acid (95:5:0.1), as an eluent. The flow-rate was 1.0 ml/min and the detection was at 225 nm. In addition, CD and UV spectra were obtained by stopped flow scanning. The method allows the determination of the stereoisomers of loxoprofen in human plasma after the administration of therapeutic dose of the racemic drug, thus HPLC with CD detector is useful for the stereospecific determination of loxoprofen products in biological samples.

  16. The pharmacokinetics of intraosseous atropine in hypovolemic swine.

    PubMed

    Yost, Jonathan; Baldwin, Phillip; Bellenger, Sarah; Bradshaw, Freida; Causapin, Edna; Demotica, Richelle; Livingston, Michael; Lee, Cynthia; Gegel, Brian; Burgert, James; Claessens, Adam; Johnson, Don; Loughren, Michael

    2015-01-01

    Compare the pharmacokinetics of atropine administered via the intravenous (IV), intramuscular (IM), and intraosseous (IO) routes in a normovolemic and hypovolemic swine model. Prospective, between subjects, experimental study. Vivarium. Yorkshire-cross swine (N = 36). Atropine was administered via IV, IM, or IO routes to normovolemic and hypovolemic swine. Blood samples were drawn at regular intervals after atropine administration and analyzed for plasma atropine concentration. Pharmacokinetic parameters were obtained from modeling the plasma concentrations. Pharmacokinetic parameters, maximum concentration (Cmax) and time to maximum concentration (Tmax). The IV and IO groups in both the normovolemic and hypovolemic models reached peak plasma concentration immediately and had a very rapid distribution phase with no apparent absorption phase for the IO groups. Peak plasma concentration and time to reach peak concentration were both significantly lower for the IM groups. There was a significant increase in absorption time with IM administration in the hypovolemic model compared to the normovolemic model. The IO route is an effective method of administering atropine and is comparable to the IV route even under conditions of significant hemorrhage. Therapeutic levels of atropine may be delayed and possibly difficult to obtain via IM injection in the presence of hypovolemic shock.

  17. Application of a novel large-volume injection method using a stomach-shaped inlet liner in capillary gas chromatographic trace analysis of dioxins in human milk and plasma.

    PubMed

    Saito, Koichi; Ohmura, Atsuko; Takekuma, Mikiko; Sasano, Ryoichi; Matsuki, Yasuhiko; Nakazawa, Hiroyuki

    2007-06-01

    A newly developed large-volume injection (LVI) technique that employs a unique stomach-shaped inlet liner (SSIL) inside of a programmable temperature vaporizer was used for the determination of trace amounts of dioxins in human milk and plasma. The initial temperature and the initial dwelling time of the inlet and the kind of solvent used were found to be critical in determining the analytical sensitivity of dioxins due to the loss of these relatively volatile compounds during solvent vaporization. Human milk and plasma were purified and fractionated by pre-packed multi-layered silica-gel chromatography and activated carbon silica-gel column chromatography. A 20-microL aliquot of the fraction collected from the chromatography with toluene was directly applied to the LVI system in high-resolution gas chromatography/high-resolution mass spectrometry. Excellent correlation (r > 0.97) between the values obtained by the LVI method using the SSIL device and those by the conventional regular-volume splitless injection method was obtained for PCDDs, PCDFs and non-ortho PCBs in human milk and plasma samples.

  18. Determination of nuvenzepine in human plasma by a sensitive sup 3 Hpirenzepine radioreceptor binding assay

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Caselli, G.; Ferrari, M.P.; Tonon, G.

    1991-02-01

    A sensitive method for the quantitation of small amounts of nuvenzepine, a new M1-selective antimuscarinic drug, in plasma is described. The analytical method involves the use of a radioreceptor binding assay based on {sup 3}Hpirenzepine displacement in rat cerebral cortex homogenates; no previous extraction is required. The method is reliable, with an interassay CV ranging from 5 to 10%, and allows the analysis of greater than 100 samples/experiment. The limit of detection is {approximately} 0.1 ng/assay. Using this method we have determined the plasma levels of nuvenzepine in eight healthy volunteers treated PO with 15 or 25 mg of nuvenzepine.HCl.more » The pharmacokinetic parameters obtained were (for 15 and 25 mg): Cmax, 64 and 131 ng/mL; AUC0-infinity, 851 and 1379 ng.h/mL; t1/2, 8.6 and 7.2 h. These values are in good agreement with those obtained using an HPLC method. Therefore, this radioreceptor binding assay proved to be simple, rapid, and specific for the determination of low levels of nuvenzepine in human plasma.« less

  19. Laser ablation-inductively coupled plasma mass spectrometry for the characterization of pigments in prehistoric rock art.

    PubMed

    Resano, Martin; García-Ruiz, Esperanza; Alloza, Ramiro; Marzo, Maria P; Vandenabeele, Peter; Vanhaecke, Frank

    2007-12-01

    In this work, several red-colored paintings of post-Paleolithic schematic style found in 10 different shelters in the vicinity of the Vero River (Huesca) were sampled and subjected to analysis by means of scanning electron microscopy-energy-dispersive X-ray spectrometry (SEM-EDX), Raman spectroscopy, and laser ablation-inductively coupled plasma mass spectrometry (LA-ICPMS). The goal of this research was to obtain meaningful information on the samples composition, in order to establish differences or similarities among them. The combined use of these techniques proved beneficial, as Raman data permitted structural information on the compounds present (hematite was identified as the main pigment, whereas calcite and gypsum are the main components of the substrate layer, as well as of the accretions that covered the pigments) to be obtained, while the quantitative values obtained by SEM were suitable for the use of Ca as internal reference during LA-ICPMS analysis. However, it was this latter technique that provided the most relevant data for fingerprinting purposes. The potential of this technique for obtaining spatially resolved information allowed the multielement quantitative analysis of the pigment layer, in spite of the presence of superficial accretions. The sensitivity of the technique permitted the determination of more than 40 elements present in a wide concentration range (from microgram per gram to 10% level) with minimum sample consumption (approximately 900 ng for each sample, corresponding to five replicates). Finally, in order to establish significant differences, only those elements showing a high correlation with Fe (As, Co, Mo, Sb, Tl, and Zr, in this case) were selected, as it is expected that these were truly present in the original pigment, while others could have migrated into the pigment layer throughout time. By using this information, it seems feasible to discriminate between various paint pots, as demonstrated for the samples under investigation.

  20. Evaluation of two platelet-rich plasma processing methods and two platelet-activation techniques for use in llamas and alpacas.

    PubMed

    Semevolos, Stacy A; Youngblood, Cori D; Grissom, Stephanie K; Gorman, M Elena; Larson, Maureen K

    2016-11-01

    OBJECTIVE To evaluate 2 processing methods (commercial kit vs conical tube centrifugation) for preparing platelet rich plasma (PRP) for use in llamas and alpacas. SAMPLES Blood samples (30 mL each) aseptically collected from 6 healthy llamas and 6 healthy alpacas. PROCEDURES PRP was prepared from blood samples by use of a commercial kit and by double-step conical tube centrifugation. A CBC was performed for blood and PRP samples. Platelets in PRP samples were activated by means of a freeze-thaw method with or without 23mM CaCl 2 , and concentrations of platelet-derived growth factor-BB and transforming growth factor-β 1 were measured. Values were compared between processing methods and camelid species. RESULTS Blood CBC values for llamas and alpacas were similar. The commercial kit yielded a significantly greater degree of platelet enrichment (mean increase, 8.5 fold vs 2.8 fold) and WBC enrichment (mean increase, 3.7 fold vs 1.9 fold) than did conical tube centrifugation. Llamas had a significantly greater degree of platelet enrichment than alpacas by either processing method. No difference in WBC enrichment was identified between species. Concentrations of both growth factors were significantly greater in PRP samples obtained by use of the commercial kit versus those obtained by conical tube centrifugation. CONCLUSIONS AND CLINICAL RELEVANCE For blood samples from camelids, the commercial kit yielded a PRP product with a higher platelet and WBC concentration than achieved by conical tube centrifugation. Optimal PRP platelet and WBC concentrations for various applications need to be determined for llamas and alpacas.

  1. Cerebrospinal fluid and plasma oxytocin concentrations are positively correlated and negatively predict anxiety in children.

    PubMed

    Carson, D S; Berquist, S W; Trujillo, T H; Garner, J P; Hannah, S L; Hyde, S A; Sumiyoshi, R D; Jackson, L P; Moss, J K; Strehlow, M C; Cheshier, S H; Partap, S; Hardan, A Y; Parker, K J

    2015-09-01

    The neuropeptide oxytocin (OXT) exerts anxiolytic and prosocial effects in the central nervous system of rodents. A number of recent studies have attempted to translate these findings by investigating the relationships between peripheral (e.g., blood, urinary and salivary) OXT concentrations and behavioral functioning in humans. Although peripheral samples are easy to obtain in humans, whether peripheral OXT measures are functionally related to central OXT activity remains unclear. To investigate a possible relationship, we quantified OXT concentrations in concomitantly collected cerebrospinal fluid (CSF) and blood samples from child and adult patients undergoing clinically indicated lumbar punctures or other CSF-related procedures. Anxiety scores were obtained in a subset of child participants whose parents completed psychometric assessments. Findings from this study indicate that plasma OXT concentrations significantly and positively predict CSF OXT concentrations (r=0.56, P=0.0064, N=27). Moreover, both plasma (r=-0.92, P=0.0262, N=10) and CSF (r=-0.91, P=0.0335, N=10) OXT concentrations significantly and negatively predicted trait anxiety scores, consistent with the preclinical literature. Importantly, plasma OXT concentrations significantly and positively (r=0.96, P=0.0115, N=10) predicted CSF OXT concentrations in the subset of child participants who provided behavioral data. This study provides the first empirical support for the use of blood measures of OXT as a surrogate for central OXT activity, validated in the context of behavioral functioning. These preliminary findings also suggest that impaired OXT signaling may be a biomarker of anxiety in humans, and a potential target for therapeutic development in individuals with anxiety disorders.

  2. Evaluation of induction of porcine dermatitis and nephropathy syndrome in gnotobiotic pigs with negative results for porcine circovirus type 2.

    PubMed

    Krakowka, Steven; Hartunian, Catherine; Hamberg, Alexander; Shoup, David; Rings, Michael; Zhang, Yan; Allan, Gordon; Ellis, John A

    2008-12-01

    To determine whether porcine dermatitis and nephropathy syndrome (PDNS) could be experimentally induced in gnotobiotic swine. Plasma samples from 27 sows and 20 conventional weaned piglets were obtained, and 30 gnotobiotic pigs were used in experiments. 3 experiments were conducted. Groups of 3-day-old gnotobiotic pigs were inoculated with pooled plasma samples obtained from healthy feeder pigs in a herd that was in the initial phases of an outbreak of respiratory disease; gross and histologic lesions of PDNS were detected in the inoculated pigs. In a second experiment, 2- and 3-day-old gnotobiotic pigs were inoculated with porcine reproductive respiratory syndrome virus (PRRSV) and with PRRSV-negative tissue homogenate containing genogroup 1 torque teno virus (g1-TTV). Lesions of PDNS were detected. Pigs inoculated with pooled plasma or the combination of tissue-culture-origin PRRSV and g1-TTV tissue homogenate developed systemic hemostatic defects, bilaterally symmetric cutaneous hemorrhages, generalized edema, icterus, bilaterally symmetric renal cortical hemorrhage, dermal vasculitis with hemorrhage, and interstitial pneumonia consistent with a clinical and pathologic diagnosis of PDNS. The PRRSV RNAs and g1-TTV DNAs were detected in plasma; all pigs seroconverted to PRRSV, and all had negative results for porcine circovirus type 2 when tested by use of PCR assays. These data suggested that PDNS is a manifestation of disseminated intravascular coagulation in swine. For the experimental conditions reported here, combined infection with g1-TTV and PRRSV was implicated in the genesis of these lesions.

  3. Influence of time, temperature and coagulation on the measurement of C3, C3 split products and C4.

    PubMed

    Sinosich, M J; Teisner, B; Brandslund, I; Fisher, M; Grudzinskas, J G

    1982-11-26

    Quantitative and qualitative immunoelectrophoretic analyses of circulating C3, C3 split products and C4 were performed in matched EDTA plasma and serum obtained from 5 normal subjects and stored for up to 48 h at room temperature (18 degrees C-22 degrees C) and 4 degrees C. Fluctuations in apparent levels of C3 were greater in serum than plasma stored at room temperature, a fall in levels seen by 24 h being followed by a significant increase. By contrast, levels of C3 did not alter if stored at 4 degrees C. C4 levels in both EDTA plasma and serum remained unchanged for 24 h, a slight decrease being seen at 48 h. Levels of C4 remained constant if samples were stored at 4 degrees C. Crossed immunoelectrophoresis revealed a significant progressive decrease in C3 levels and a simultaneous increase in C3c occurring after 4 h in serum and 8 h in EDTA plasma, stored at room temperature. In studies conducted at 4 degrees C, similar but delayed fluctuations were seen. A progressive and significant increase in C3d levels was seen in both plasma and serum samples stored at room temperature, levels rising to 276% (plasma) and 308% (serum) of levels seen at zero time. At 4 degrees C marginal increases in C3d levels only were observed. These results suggest that in vitro degradation of C3 and C4 are readily facilitated by temperature, time and coagulation, and that conditions of collection and storage of samples must be optimized for the accurate definition of activation of the complement cascade.

  4. Antibody index and specific antibody quotient in horses after intragastric administration of Sarcocystis neurona sporocysts.

    PubMed

    Heskett, Katherine A; Mackay, Robert J

    2008-03-01

    To investigate the use of a specific antibody index (AI) that relates Sarcocystis neurona-specific IgG quotient (Q(SN)) to total IgG quotient (Q(IgG)) for the detection of the anti-S neurona antibody fraction of CNS origin in CSF samples obtained from horses after intragastric administration of S neurona sporocysts. 18 adult horses. 14 horses underwent intragastric inoculation (day 0) with S neurona sporocysts, and 4 horses remained unchallenged; blood and CSF samples were collected on days - 1 and 84. For purposes of another study, some challenged horses received intermittent administration of ponazuril (20 mg/kg, PO). Sarcocystis neurona-specific IgG concentrations in CSF (SN(CSF)) and plasma (SN(plasma)) were measured via a direct ELISA involving merozoite lysate antigen and reported as ELISA units (EUs; arbitrary units based on a nominal titer for undiluted immune plasma of 100,000 EUs/mL). Total IgG concentrations in CSF (IgG(CSF)) and plasma (IgG(plasma)) were quantified via a sandwich ELISA and a radial immunodiffusion assay, respectively; Q(SN), Q(IgG), and AI were calculated. Following sporocyst challenge, mean +/- SEM SN(CSF) and SN(plasma) increased significantly (from 8.8 +/- 1.0 EUs/mL to 270.0 +/- 112.7 EUs/mL and from 1,737 +/- 245 EUs/mL to 43,169 +/- 13,770 EUs/mL, respectively). Challenge did not affect total IgG concentration, Q(SN), Q(IgG), or AI. S neurona-specific IgG detected in CSF samples from sporocyst-challenged horses appeared to be extraneural in origin; thus, this experimental challenge may not reliably result in CNS infection. Calculation of a specific AI may have application to the diagnosis of S neurona-associated myeloencephalitis in horses.

  5. Estimation of Monocrotophos renal elimination half-life in humans.

    PubMed

    Jose, Arun; Selvakumar, Ratnasamy; Peter, John Victor; Karthik, Gunasekaran; Fleming, Denise Helen; Fleming, Jude Joseph

    2015-01-01

    Monocrotophos, implicated in about 1/4th of organophosphate poisonings in our centre, is associated with the highest mortality (24%). Yet data on its pharmacokinetics in humans is limited. We estimated the renal elimination half-life of monocrotophos. Consecutive patients presenting with monocrotophos overdose over a 2-month period who had normal renal function were recruited. Monocrotophos in plasma and urine were quantitated by high-performance liquid chromatography. Urine was obtained from catheterised samples at 0-2, 2-4, 4-6, 6-8, 8-12 and 12-24 h. Plasma specimens were collected at the time of admission, and at the midpoint of the urine sample collections at 1, 3, 5, 7, 10, 15 and 21 h. Renal elimination half-life was calculated from the cumulative amount excreted in the urine. The cohort of 5 male patients, aged 35.8 ± 2.94 years, presented with typical organophosphate (cholinergic) toxidrome following intentional monocrotophos overdose. All patients required mechanical ventilation; one patient died. Plasma data was available from 5 patients and urine data from 3 patients. The median renal elimination half-life was 3.3 (range: 1.9-5.0 h). Plasma monocrotophos values, as natural log, fell in a linear fashion up to around 10 h after admission. After the 10-hour period, there was a secondary rise in values in all the 3 patients in whom sampling was continued after 10 h. A renal elimination half-life of 3.3 h for monocrotophos is consistent with a water-soluble compound which is rapidly cleared from the plasma. The secondary rise in plasma monocrotophos values suggests possible re-distribution. Determining the elimination profile of this compound will help develop better strategies for treatment.

  6. Intestinal microbiota-derived metabolomic blood plasma markers for prior radiation injury.

    PubMed

    Ó Broin, Pilib; Vaitheesvaran, Bhavapriya; Saha, Subhrajit; Hartil, Kirsten; Chen, Emily I; Goldman, Devorah; Fleming, William Harv; Kurland, Irwin J; Guha, Chandan; Golden, Aaron

    2015-02-01

    Assessing whole-body radiation injury and absorbed dose is essential for remediation efforts following accidental or deliberate exposure in medical, industrial, military, or terrorist incidents. We hypothesize that variations in specific metabolite concentrations extracted from blood plasma would correlate with whole-body radiation injury and dose. Groups of C57BL/6 mice (n=12 per group) were exposed to 0, 2, 4, 8, and 10.4 Gy of whole-body gamma radiation. At 24 hours after treatment, all animals were euthanized, and both plasma and liver biopsy samples were obtained, the latter being used to identify a distinct hepatic radiation injury response within plasma. A semiquantitative, untargeted metabolite/lipid profile was developed using gas chromatography-mass spectrometry and liquid chromatography-tandem mass spectrometry, which identified 354 biochemical compounds. A second set of C57BL/6 mice (n=6 per group) were used to assess a subset of identified plasma markers beyond 24 hours. We identified a cohort of 37 biochemical compounds in plasma that yielded the optimal separation of the irradiated sample groups, with the most correlated metabolites associated with pyrimidine (positively correlated) and tryptophan (negatively correlated) metabolism. The latter were predominantly associated with indole compounds, and there was evidence that these were also correlated between liver and plasma. No evidence of saturation as a function of dose was observed, as has been noted for studies involving metabolite analysis of urine. Plasma profiling of specific metabolites related to pyrimidine and tryptophan pathways can be used to differentiate whole-body radiation injury and dose response. As the tryptophan-associated indole compounds have their origin in the intestinal microbiome and subsequently the liver, these metabolites particularly represent an attractive marker for radiation injury within blood plasma. Copyright © 2015 Elsevier Inc. All rights reserved.

  7. Composition of plasma and atheromatous plaque among coronary artery disease subjects consuming coconut oil or sunflower oil as the cooking medium.

    PubMed

    Palazhy, Sabitha; Kamath, Prakash; Rajesh, P C; Vaidyanathan, Kannan; Nair, Shiv K; Vasudevan, D M

    2012-12-01

    Coconut oil, which is rich in medium-chain saturated fatty acids, is the principal cooking medium of the people of Kerala, India. Replacement of saturated fat with polyunsaturated fat is effective in reducing serum cholesterol levels. However, the effect of substituting coconut oil with sunflower oil on the fatty acid composition of plaque has not been thoroughly investigated. We therefore evaluated and compared the fatty acid composition of plasma and plaque among subjects consuming coconut oil or sunflower oil as the cooking medium. Endarterectomy samples and plasma samples were obtained from subjects who underwent coronary artery bypass grafts (n = 71). The subjects were grouped based on the type of oil they were using as their cooking medium (coconut oil or sunflower oil). The fatty acid composition in the plaques and the plasma was determined by HPLC and the data were analyzed statistically. Sunflower oil consumers had elevated concentrations of linoleic acid (p = 0.001) in plasma, while coconut oil users had higher myristic acid levels (p = 0.011) in plasma. Medium-chain fatty acids did not differ significantly between the two groups in the plasma. Medium-chain fatty acids were detected in the plaques in both groups of subjects. In contrast to previous reports, long-chain saturated fatty acids dominated the lipid content of plaque in this population, and the fatty acid composition of plaque was not significantly different between the two groups. No correlation between fatty acids of plasma and plaque was observed in either group. A change in cooking medium, although it altered the plasma fatty acid composition, was not reflected in the plaque composition.

  8. Simultaneous determination of chlorinated organic compounds from environmental samples using gas chromatography coupled with a micro electron capture detector and micro-plasma atomic emission detector

    NASA Astrophysics Data System (ADS)

    Quan, Xie; Chen, Shuo; Platzer, Bernhard; Chen, Jingwen; Gfrerer, Marion

    2002-01-01

    Water and sediment samples were screened simultaneously for the presence of polychlorinated organic compounds using gas chromatography (GC) coupled with an micro electron capture detector (μ-ECD) and a newly developed helium plasma based on a micro-atomic emission detector (μ-AED). The GC column effluent was split 15:85 between two detectors. In this way, two chromatograms, one obtained by μ-ECD and another by μ-AED, were recorded simultaneously. α-, β-hexachlorocyclohexane and p, p'-DDE were detected. RSDs of the monitoring results from the two detection methods were <20% for the three compounds. A detection limit of 8.5 pg and at least 3 orders of magnitude of linear range for μ-AED was observed.

  9. Process Research of Polycrystalline Silicon Material (PROPSM)

    NASA Technical Reports Server (NTRS)

    Culik, J. S.

    1984-01-01

    A passivation process (hydrogenation) that will improve the power generation of solar cells fabricated from presently produced, large grain, cast polycrystalline silicon (Semix), a potentially low cost material are developed. The first objective is to verify the operation of a DC plasma hydrogenation system and to investigate the effect of hydrogen on the electrical performance of a variety of polycrystalline silicon solar cells. The second objective is to parameterize and optimize a hydrogenation process for cast polycrystalline silicon, and will include a process sensitivity analysis. The sample preparation for the first phase is outlined. The hydrogenation system is described, and some early results that were obtained using the hydrogenation system without a plasma are summarized. Light beam induced current (LBIC) measurements of minicell samples, and their correlation to dark current voltage characteristics, are discussed.

  10. Bacterial adhesion on conventional and self-ligating metallic brackets after surface treatment with plasma-polymerized hexamethyldisiloxane.

    PubMed

    Tupinambá, Rogerio Amaral; Claro, Cristiane Aparecida de Assis; Pereira, Cristiane Aparecida; Nobrega, Celestino José Prudente; Claro, Ana Paula Rosifini Alves

    2017-01-01

    Plasma-polymerized film deposition was created to modify metallic orthodontic brackets surface properties in order to inhibit bacterial adhesion. Hexamethyldisiloxane (HMDSO) polymer films were deposited on conventional (n = 10) and self-ligating (n = 10) stainless steel orthodontic brackets using the Plasma-Enhanced Chemical Vapor Deposition (PECVD) radio frequency technique. The samples were divided into two groups according to the kind of bracket and two subgroups after surface treatment. Scanning Electron Microscopy (SEM) analysis was performed to assess the presence of bacterial adhesion over samples surfaces (slot and wings region) and film layer integrity. Surface roughness was assessed by Confocal Interferometry (CI) and surface wettability, by goniometry. For bacterial adhesion analysis, samples were exposed for 72 hours to a Streptococcus mutans solution for biofilm formation. The values obtained for surface roughness were analyzed using the Mann-Whitney test while biofilm adhesion were assessed by Kruskal-Wallis and SNK test. Significant statistical differences (p< 0.05) for surface roughness and bacterial adhesion reduction were observed on conventional brackets after surface treatment and between conventional and self-ligating brackets; no significant statistical differences were observed between self-ligating groups (p> 0.05). Plasma-polymerized film deposition was only effective on reducing surface roughness and bacterial adhesion in conventional brackets. It was also noted that conventional brackets showed lower biofilm adhesion than self-ligating brackets despite the absence of film.

  11. Sensitive determination of three aconitum alkaloids and their metabolites in human plasma by matrix solid-phase dispersion with vortex-assisted dispersive liquid-liquid microextraction and HPLC with diode array detection.

    PubMed

    Wang, Xiaozhong; Li, Xuwen; Li, Lanjie; Li, Min; Liu, Ying; Wu, Qian; Li, Peng; Jin, Yongri

    2016-05-01

    A simple and sensitive method for determination of three aconitum alkaloids and their metabolites in human plasma was developed using matrix solid-phase dispersion combined with vortex-assisted dispersive liquid-liquid microextraction and high-performance liquid chromatography with diode array detection. The plasma sample was directly purified by matrix solid-phase dispersion and the eluate obtained was concentrated and further clarified by vortex-assisted dispersive liquid-liquid microextraction. Some important parameters affecting the extraction efficiency, such as type and amount of dispersing sorbent, type and volume of elution solvent, type and volume of extraction solvent, salt concentration as well as sample solution pH, were investigated in detail. Under optimal conditions, the proposed method has good repeatability and reproducibility with intraday and interday relative standard deviations lower than 5.44 and 5.75%, respectively. The recoveries of the aconitum alkaloids ranged from 73.81 to 101.82%, and the detection limits were achieved within the range of 1.6-2.1 ng/mL. The proposed method offered the advantages of good applicability, sensitivity, simplicity, and feasibility, which makes it suitable for the determination of trace amounts of aconitum alkaloids in human plasma samples. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  12. Serum androgen levels in women who have recurrent miscarriages and their correlation with markers of endometrial function.

    PubMed

    Okon, M A; Laird, S M; Tuckerman, E M; Li, T C

    1998-04-01

    To compare plasma androgen concentrations in women who have recurrent miscarriages and in fertile women, and to correlate the results with concentrations of the endometrial protein PP14 in uterine flushings and plasma from women who have recurrent miscarriages. Retrospective study. Hospital research unit. Women attending a recurrent miscarriage clinic and normal fertile volunteers. Ten of the women with recurrent miscarriages had polycystic ovary disease (PCOD) as assessed by ultrasonography or increased follicular LH levels. Plasma samples were obtained from the women on days LH-7, LH-4, LH+0, and LH+7 or LH+10 of a cycle. An endometrial flushing sample and a biopsy specimen were taken from women with recurrent miscarriages on day LH+7 or LH+10. Androstenedione, testosterone, and sex hormone-binding globulin (SHBG) were measured in the plasma samples. The endometrial protein PP14 was measured in the uterine flushings and in the LH+7 or LH+10 plasma samples from the women with recurrent miscarriages. Testosterone concentrations were higher in the women with recurrent miscarriages both with and without PCOD on days LH-7 and LH-4 of the cycle. Concentrations of androstenedione also were higher in the women with recurrent miscarriages, but without PCOD on day LH-7. Testosterone SHBG ratios were higher in the women with recurrent miscarriages, without PCOD compared with the controls on days LH-7, LH+0, and LH+7. Mean follicular testosterone concentrations were correlated negatively with both uterine (r = -0.47) and plasma (r = -0.49) PP14 levels on day LH+10. Mean luteal phase testosterone SHBG ratios were correlated negatively with uterine PP14 concentrations on day LH+7 of the cycle (r = -0.674). Androgen levels are higher in women who have recurrent miscarriages than in normal fertile controls. These high levels of androgens may have a detrimental effect on endometrial function.

  13. Enhanced retained dose uniformity in NiTi spinal correction rod treated by three-dimensional mesh-assisted nitrogen plasma immersion ion implantation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lu, Q. Y.; Hu, T.; Kwok, Dixon T. K.

    2010-05-15

    Owing to the nonconformal plasma sheath in plasma immersion ion implantation of a rod sample, the retained dose can vary significantly. The authors propose to improve the implant uniformity by introducing a metal mesh. The depth profiles obtained with and without the mesh are compared and the implantation temperature at various locations is evaluated indirectly by differential scanning calorimeter. Our results reveal that by using the metal mesh, the retained dose uniformity along the length is greatly improved and the effects of the implantation temperature on the localized mechanical properties of the implanted NiTi shape memory alloy rod are nearlymore » negligible.« less

  14. Frequent Cross-Resistance to Dapivirine in HIV-1 Subtype C-Infected Individuals after First-Line Antiretroviral Therapy Failure in South Africa.

    PubMed

    Penrose, Kerri J; Wallis, Carole L; Brumme, Chanson J; Hamanishi, Kristen A; Gordon, Kelley C; Viana, Raquel V; Harrigan, P Richard; Mellors, John W; Parikh, Urvi M

    2017-02-01

    A vaginal ring containing dapivirine (DPV) has shown moderate protective efficacy against HIV-1 acquisition, but the activity of DPV against efavirenz (EFV)- and nevirapine (NVP)-resistant viruses that could be transmitted is not well defined. We investigated DPV cross-resistance of subtype C HIV-1 from individuals on failing NVP- or EFV-containing antiretroviral therapy (ART) in South Africa. Plasma samples were obtained from individuals with >10,000 copies of HIV RNA/ml and with HIV-1 containing at least one non-nucleoside reverse transcriptase (NNRTI) mutation. Susceptibility to NVP, EFV, and DPV in TZM-bl cells was determined for recombinant HIV-1 LAI containing bulk-amplified, plasma-derived, full-length reverse transcriptase sequences. Fold change (FC) values were calculated compared with a composite 50% inhibitory concentration (IC 50 ) from 12 recombinant subtype C HIV-1 LAI plasma-derived viruses from treatment-naive individuals in South Africa. A total of 25/100 (25%) samples showed >500-FCs to DPV compared to treatment-naive samples with IC 50 s exceeding the maximum DPV concentration tested (132 ng/ml). A total of 66/100 (66%) samples displayed 3- to 306-FCs, with a median IC 50 of 17.6 ng/ml. Only 9/100 (9%) samples were susceptible to DPV (FC < 3). Mutations L100I and K103N were significantly more frequent in samples with >500-fold resistance to DPV compared to samples with a ≤500-fold resistance. A total of 91% of samples with NNRTI-resistant HIV-1 from individuals on failing first-line ART in South Africa exhibited ≥3-fold cross-resistance to DPV. This level of resistance exceeds expected plasma concentrations, but very high genital tract DPV concentrations from DPV ring use could block viral replication. It is critically important to assess the frequency of transmitted and selected DPV resistance in individuals using the DPV ring. Copyright © 2017 American Society for Microbiology.

  15. Frequent Cross-Resistance to Dapivirine in HIV-1 Subtype C-Infected Individuals after First-Line Antiretroviral Therapy Failure in South Africa

    PubMed Central

    Penrose, Kerri J.; Wallis, Carole L.; Brumme, Chanson J.; Hamanishi, Kristen A.; Gordon, Kelley C.; Viana, Raquel V.; Harrigan, P. Richard; Mellors, John W.

    2016-01-01

    ABSTRACT A vaginal ring containing dapivirine (DPV) has shown moderate protective efficacy against HIV-1 acquisition, but the activity of DPV against efavirenz (EFV)- and nevirapine (NVP)-resistant viruses that could be transmitted is not well defined. We investigated DPV cross-resistance of subtype C HIV-1 from individuals on failing NVP- or EFV-containing antiretroviral therapy (ART) in South Africa. Plasma samples were obtained from individuals with >10,000 copies of HIV RNA/ml and with HIV-1 containing at least one non-nucleoside reverse transcriptase (NNRTI) mutation. Susceptibility to NVP, EFV, and DPV in TZM-bl cells was determined for recombinant HIV-1LAI containing bulk-amplified, plasma-derived, full-length reverse transcriptase sequences. Fold change (FC) values were calculated compared with a composite 50% inhibitory concentration (IC50) from 12 recombinant subtype C HIV-1LAI plasma-derived viruses from treatment-naive individuals in South Africa. A total of 25/100 (25%) samples showed >500-FCs to DPV compared to treatment-naive samples with IC50s exceeding the maximum DPV concentration tested (132 ng/ml). A total of 66/100 (66%) samples displayed 3- to 306-FCs, with a median IC50 of 17.6 ng/ml. Only 9/100 (9%) samples were susceptible to DPV (FC < 3). Mutations L100I and K103N were significantly more frequent in samples with >500-fold resistance to DPV compared to samples with a ≤500-fold resistance. A total of 91% of samples with NNRTI-resistant HIV-1 from individuals on failing first-line ART in South Africa exhibited ≥3-fold cross-resistance to DPV. This level of resistance exceeds expected plasma concentrations, but very high genital tract DPV concentrations from DPV ring use could block viral replication. It is critically important to assess the frequency of transmitted and selected DPV resistance in individuals using the DPV ring. PMID:27895013

  16. Electro membrane extraction of sodium diclofenac as an acidic compound from wastewater, urine, bovine milk, and plasma samples and quantification by high-performance liquid chromatography.

    PubMed

    Davarani, Saied Saeed Hosseiny; Pourahadi, Ahmad; Nojavan, Saeed; Banitaba, Mohammad Hossein; Nasiri-Aghdam, Mahnaz

    2012-04-13

    Electro membrane extraction (EME) as a new microextraction method was applied for extraction of sodium diclofenac (SDF) as an acidic compound from wastewater, urine, bovine milk and plasma samples. Under applied potential of 20 V during the extraction, SDF migrated from a 2.1 mL of sample solution (1mM NaOH), through a supported liquid membrane (SLM), into a 30 μL acceptor solution (10 mM NaOH), exist inside the lumen of the hollow fiber. The negative electrode was placed in the donor solution, and the positive electrode was placed in the acceptor solution. 1-octanol was immobilized in the pores of a porous hollow fiber of polypropylene as SLM. Then the extract was analyzed by means of high-performance liquid chromatography (HPLC) with UV-detection for quantification of SDF. Best results were obtained using a phosphate running electrolyte (10 mM, pH 2.5). The ranges of quantitation for different samples were 8-500 ngmL(-1). Intra- and inter-day RSDs were less than 14.5%. Under the optimized conditions, the preconcentration factors were between 31 and 66 and also the limit of detections (LODs) ranged from 2.7 ng mL(-1) to 5 ng mL(-1) in different samples. This procedure was applied to determine SDF in wastewater, bovine milk, urine and plasma samples (spiked and real samples). Extraction recoveries for different samples were between 44-95% after 5 min of extraction. Copyright © 2012 Elsevier B.V. All rights reserved.

  17. Effects of ketoconazole on the pharmacokinetics and pharmacodynamics of morphine in healthy Greyhounds.

    PubMed

    Kukanich, Butch; Borum, Stacy L

    2008-05-01

    To assess pharmacokinetics and pharmacodynamics of morphine and the effects of ketoconazole on the pharmacokinetics and pharmacodynamics of morphine in healthy Greyhounds. 6 healthy Greyhounds, 3 male and 3 female. Morphine sulfate (0.5 mg/kg. IV) was administered to Greyhounds prior to and after 5 days of ketoconazole (12.7 +/- 0.6 mg/kg, PO) treatment. Plasma samples were obtained from blood samples that were collected at predetermined time points for measurement of morphine and ketoconazole concentrations by mass spectrometry. Pharmacokinetics of morphine were estimated by use of computer software. Pharmacodynamic effects of morphine in Greyhounds were similar to those of other studies in dogs and were similar between treatment groups. Morphine was rapidly eliminated with a half-life of 1.28 hours and a plasma clearance of 32.55 mL/min/kg. The volume of distribution was 3.6 L/kg. No significant differences in the pharmacokinetics of morphine were found after treatment with ketoconazole. Plasma concentrations of ketoconazole were high and persisted longer than expected in Greyhounds. Ketoconazole had no significant effect on morphine pharmacokinetics, and the pharmacodynamics were similar between treatment groups. Plasma concentrations of ketoconazole were higher than expected and persisted longer than expected in Greyhounds.

  18. Determination of flavonoids from Orthosiphon stamineus in plasma using a simple HPLC method with ultraviolet detection.

    PubMed

    Loon, Yit Hong; Wong, Jia Woei; Yap, Siew Ping; Yuen, Kah Hay

    2005-02-25

    A simple liquid chromatographic method was developed for the simultaneous determination of flavonoids from Orthosiphon stamineus Benth, namely sinensitin, eupatorin and 3'-hydroxy-5,6,7,4'-tetramethoxyflavone, in plasma. Prior to analysis, the flavonoids and the internal standard (naproxen) were extracted from plasma samples using a 1:1 mixture of ethyl acetate and chloroform. The detection and quantification limits for the three flavonoids were similar being 3 and 5 ng/ml, respectively. The within-day and between-day accuracy values, expressed as percentage of true values, for the three flavonoids were between 95 and 107%, while the corresponding precision, expressed as coefficients of variation, for the three flavonoids were less than 14%. In addition, the mean recovery values of the extraction procedure for all the flavonoids were between 92 and 114%. The calibration curves were linear over a concentration range of 5-4000 ng/ml. The present method was applied to analyse plasma samples obtained from a pilot study using rats in which the mean absolute oral bioavailability values for sinensitin, eupatorin and 3'-hydroxy-5,6,7,4'-tetramethoxyflavone was 9.4, 1.0 and 1.5%, respectively.

  19. Can Saliva and Plasma Methadone Concentrations Be Used for Enantioselective Pharmacokinetic and Pharmacodynamic Studies in Patients With Advanced Cancer?

    PubMed

    George, Rani; Haywood, Alison; Good, Phillip; Hennig, Stefanie; Khan, Sohil; Norris, Ross; Hardy, Janet

    2017-09-01

    Methadone is a potent analgesic used to treat refractory cancer pain. It is administered as a racemic mixture, with the l-enantiomer being primarily a μ-receptor agonist, whereas the d-enantiomer is an N-methyl-d-aspartate antagonist and inhibits serotonin and norepinephrine reuptake. Dose requirements vary greatly among patients to achieve optimal pain control and to avoid the risk of adverse effects. The relationship between plasma and saliva methadone enantiomer concentrations was investigated to determine if saliva could be a substitute for plasma in pharmacodynamic and pharmacokinetic studies for clinical monitoring and dose optimization of methadone in patients with advanced cancer. Patients with advanced cancer who were prescribed varying doses of oral methadone for pain management were recruited to obtain paired plasma and saliva samples. Pain scores were recorded at the time of sampling. The total and unbound plasma and saliva concentrations of the l- and d-enantiomers of methadone were quantified by using an HPLC-MS/MS method. The relationship between plasma (total and unbound) and saliva concentrations were compared. The saliva-to-plasma concentration ratio was compared versus the dose administered and the time after dosing for both enantiomers. The association of methadone concentrations with reported pain scores was compared by using a Mann-Whitney U test for significance. Fifty patients receiving a mean dose of 11mg/d of methadone provided 151 paired plasma and saliva samples. The median age of the population was 61 years with an interquartile range of 53-71 years with total body weight ranging from 59-88 kg. Median (interquartile) total plasma concentrations for l- and d-methadone were 50.78 ng/mL (30.6-113.0 ng/mL) and 62.0 ng/mL (28.7-116.0 ng/mL), respectively. Median (interquartile range) saliva concentrations for l- and d-methadone were 81.5 ng/mL (28.0-203.2 ng/mL) and 44.2 (16.2-149.7 ng/mL). No relationship could be established between plasma and saliva concentrations for l- and d-methadone (r 2 = 0.35 and 0.25). The saliva-to-plasma concentration analyzed with the methadone dose showed higher saliva concentrations at lower doses. Dose-normalized saliva concentrations followed a similar pattern over time compared with plasma concentrations. No correlation was found between l-methadone plasma, d-methadone plasma, l-methadone saliva, d-methadone saliva concentrations, and pain score. Saliva concentration was not a better predictor of pain control than plasma concentration for dose optimization and monitoring studies of methadone in patients with cancer. Although the saliva-to-plasma ratio of the concentration of methadone enantiomers was stable across the dosing range, due to the variability in individual saliva-to-plasma ratios, saliva sampling may not be a valid substitute in pharmacokinetic studies of methadone in cancer. Copyright © 2017 Elsevier HS Journals, Inc. All rights reserved.

  20. Long-term exposure to electromagnetic radiation from mobile phones and Wi-Fi devices decreases plasma prolactin, progesterone, and estrogen levels but increases uterine oxidative stress in pregnant rats and their offspring.

    PubMed

    Yüksel, Murat; Nazıroğlu, Mustafa; Özkaya, Mehmet Okan

    2016-05-01

    We investigated the effects of mobile phone (900 and 1800 MHz)- and Wi-Fi (2450 MHz)-induced electromagnetic radiation (EMR) exposure on uterine oxidative stress and plasma hormone levels in pregnant rats and their offspring. Thirty-two rats and their forty newborn offspring were divided into the following four groups according to the type of EMR exposure they were subjected to: the control, 900, 1800, and 2450 MHz groups. Each experimental group was exposed to EMR for 60 min/day during the pregnancy and growth periods. The pregnant rats were allowed to stand for four generations (total 52 weeks) before, plasma and uterine samples were obtained. During the 4th, 5th, and 6th weeks of the experiment, plasma and uterine samples were also obtained from the developing rats. Although uterine lipid peroxidation increased in the EMR groups, uterine glutathione peroxidase activity (4th and 5th weeks) and plasma prolactin levels (6th week) in developing rats decreased in these groups. In the maternal rats, the plasma prolactin, estrogen, and progesterone levels decreased in the EMR groups, while the plasma total oxidant status, and body temperatures increased. There were no changes in the levels of reduced glutathione, total antioxidants, or vitamins A, C, and E in the uterine and plasma samples of maternal rats. In conclusion, although EMR exposure decreased the prolactin, estrogen, and progesterone levels in the plasma of maternal rats and their offspring, EMR-induced oxidative stress in the uteri of maternal rats increased during the development of offspring. Mobile phone- and Wi-Fi-induced EMR may be one cause of increased oxidative uterine injury in growing rats and decreased hormone levels in maternal rats. TRPV1 cation channels are the possible molecular pathways responsible for changes in the hormone, oxidative stress, and body temperature levels in the uterus of maternal rats following a year-long exposure to electromagnetic radiation exposure from mobile phones and Wi-Fi devices. It is likely that TRPV1-mediated Ca(2+) entry in the uterus of pregnant rats involves accumulation of oxidative stress and opening of mitochondrial membrane pores that consequently leads to mitochondrial dysfunction, substantial swelling of the mitochondria with rupture of the outer membrane and release of oxidants such as superoxide (O2 (-)) and hydrogen peroxide (H2O2). The superoxide radical is converted to H2O2 by superoxide dismutase (SOD) enzyme. Glutathione peroxidase (GSH-Px) is an important antioxidant enzyme for removing lipid hydroperoxides and hydrogen peroxide and it catalyzes the reduction of H2O2 to water.

  1. Measurement of plasma cell-free DNA concentrations in dogs with sepsis, trauma, and neoplasia.

    PubMed

    Letendre, Jo-Annie; Goggs, Robert

    2017-05-01

    To determine if cell-free DNA (cfDNA) was identifiable in canine plasma, to evaluate 3 techniques for the measurement of plasma cfDNA concentrations in dogs presented to an emergency service, and to compare the plasma cfDNA concentrations of healthy dogs to those with sepsis, trauma, and neoplasia. Retrospective study of banked canine plasma samples collected between May 2014 and December 2014. Dogs presented to the emergency service of a university veterinary teaching hospital. Plasma cfDNA was measured on residual plasma samples obtained from 15 dogs with sepsis, 15 dogs with moderate-severe trauma, 15 dogs diagnosed with a sarcoma. Plasma cfDNA was also measured in 15 healthy dogs. None. Assay linearity, repeatability, and reproducibility were evaluated. Quantification of cfDNA was performed in duplicate on diluted citrated plasma and following DNA purification using 2 fluorescence assays (SYBR-Gold; Quant-iT) and by ultraviolet absorbance spectroscopy. Fluorescence intensities (FIs) were converted to cfDNA concentrations using standard curves. Median FI values and cfDNA concentrations were compared to healthy controls using the Kruskal-Wallis test, with adjustment for multiple comparisons. Alpha was set at 0.05. Both assays had excellent linearity, and acceptable repeatability and reproducibility. Compared to controls, plasma cfDNA concentrations were significantly increased in dogs with sepsis or moderate-severe trauma with both assays (P ≤ 0.003). Dogs with neoplasia had significantly increased cfDNA concentrations with the Quant-iT assay only (P = 0.003). When measurements were performed on purified DNA, only dogs with moderate-severe trauma had significantly increased cfDNA concentrations (P < 0.001; SYBR-Gold assay). cfDNA can be readily identified in canine plasma using 2 fluorescence assays. DNA extraction offers no advantage over direct measurement. Compared to healthy controls, dogs with sepsis or moderate-severe trauma have significantly increased plasma cfDNA concentrations. © Veterinary Emergency and Critical Care Society 2017.

  2. Standardization of a fluconazole bioassay and correlation of results with those obtained by high-pressure liquid chromatography.

    PubMed Central

    Rex, J H; Hanson, L H; Amantea, M A; Stevens, D A; Bennett, J E

    1991-01-01

    An improved bioassay for fluconazole was developed. This assay is sensitive in the clinically relevant range (2 to 40 micrograms/ml) and analyzes plasma, serum, and cerebrospinal fluid specimens; bioassay results correlate with results obtained by high-pressure liquid chromatography (HPLC). Bioassay and HPLC analyses of spiked plasma, serum, and cerebrospinal fluid samples (run as unknowns) gave good agreement with expected values. Analysis of specimens from patients gave equivalent results by both HPLC and bioassay. HPLC had a lower within-run coefficient of variation (less than 2.5% for HPLC versus less than 11% for bioassay) and a lower between-run coefficient of variation (less than 5% versus less than 12% for bioassay) and was more sensitive (lower limit of detection, 0.1 micrograms/ml [versus 2 micrograms/ml for bioassay]). The bioassay is, however, sufficiently accurate and sensitive for clinical specimens, and its relative simplicity, low sample volume requirement, and low equipment cost should make it the technique of choice for analysis of routine clinical specimens. PMID:1854166

  3. Biotechnological traps for the reduction of inflammation due to cardiopulmonary bypass operations.

    PubMed

    Grano, Valentina; Salamino, Franca; Melloni, Edon; Minafra, Roberto; Regola, Eliana; Diano, Nadia; Nicolucci, Carla; Attanasio, Angelina; Nappi, Gianantonio; Cotrufo, Maurizio; Maresca, Lucio; De Santo, Natale Gaspare; Mita, Damiano Gustavo

    2006-07-01

    Cardiopulmonary bypass induces a systemic inflammatory response (SIR), characterized by the activation of cellular and humoral elements, with concomitant release of neutrophil elastase and matrix-metallo proteinases. In the present study, the protease release during extracorporeal circulation in 28 patients undergoing cardiac surgical operations was monitored using casein zymography. A peak in protease activity was found in all patients at the end of cardiopulmonary bypass. Plasma samples of patients were allowed to interact with different traps obtained by immobilizing different protease inhibitors on specific carriers. alpha1-Antitrypsin, Bovine Pancreatic Trypsin Inhibitor, Elastatinal or Leupeptin were used as inhibitors and were covalently immobilized by diazotization or by condensation. A reduction in the proteolytic activity of the plasma samples was observed after interaction with the different traps. The most efficient traps, i.e. the ones displaying greatest power to inhibit protease activity, were those obtained by immobilizing Bovine Pancreatic Trypsin Inhibitor and Leupeptin. The biocompatibility of traps was also tested. Results show that protease activity in blood can be decreased by our protease traps.

  4. Rapid and sensitive determination of tellurium in soil and plant samples by sector-field inductively coupled plasma mass spectrometry.

    PubMed

    Yang, Guosheng; Zheng, Jian; Tagami, Keiko; Uchida, Shigeo

    2013-11-15

    In this work, we report a rapid and highly sensitive analytical method for the determination of tellurium in soil and plant samples using sector field inductively coupled plasma mass spectrometry (SF-ICP-MS). Soil and plant samples were digested using Aqua regia. After appropriate dilution, Te in soil and plant samples was directly analyzed without any separation and preconcentration. This simple sample preparation approach avoided to a maximum extent any contamination and loss of Te prior to the analysis. The developed analytical method was validated by the analysis of soil/sediment and plant reference materials. Satisfactory detection limits of 0.17 ng g(-1) for soil and 0.02 ng g(-1) for plant samples were achieved, which meant that the developed method was applicable to studying the soil-to-plant transfer factor of Te. Our work represents for the first time that data on the soil-to-plant transfer factor of Te were obtained for Japanese samples which can be used for the estimation of internal radiation dose of radioactive tellurium due to the Fukushima Daiichi Nuclear Power Plant accident. Copyright © 2013 Elsevier B.V. All rights reserved.

  5. Statistical inference from multiple iTRAQ experiments without using common reference standards.

    PubMed

    Herbrich, Shelley M; Cole, Robert N; West, Keith P; Schulze, Kerry; Yager, James D; Groopman, John D; Christian, Parul; Wu, Lee; O'Meally, Robert N; May, Damon H; McIntosh, Martin W; Ruczinski, Ingo

    2013-02-01

    Isobaric tags for relative and absolute quantitation (iTRAQ) is a prominent mass spectrometry technology for protein identification and quantification that is capable of analyzing multiple samples in a single experiment. Frequently, iTRAQ experiments are carried out using an aliquot from a pool of all samples, or "masterpool", in one of the channels as a reference sample standard to estimate protein relative abundances in the biological samples and to combine abundance estimates from multiple experiments. In this manuscript, we show that using a masterpool is counterproductive. We obtain more precise estimates of protein relative abundance by using the available biological data instead of the masterpool and do not need to occupy a channel that could otherwise be used for another biological sample. In addition, we introduce a simple statistical method to associate proteomic data from multiple iTRAQ experiments with a numeric response and show that this approach is more powerful than the conventionally employed masterpool-based approach. We illustrate our methods using data from four replicate iTRAQ experiments on aliquots of the same pool of plasma samples and from a 406-sample project designed to identify plasma proteins that covary with nutrient concentrations in chronically undernourished children from South Asia.

  6. Hepatocytes express the antimicrobial peptide HBD-2 after multiple trauma: an experimental study in human and mice.

    PubMed

    Fitschen-Oestern, Stefanie; Weuster, Matthias; Lippross, Sebastian; Behrendt, Peter; Fuchs, Sabine; Pufe, Thomas; Tohidnezhad, Mersedeh; Bayer, Andreas; Seekamp, Andreas; Varoga, Deike; Klüter, Tim

    2017-03-07

    Human-beta defensins (HBD) belong to the family of acute phase peptides and hold a broad antimicrobial spectrum that includes gram-positive and gram-negative bacteria. HBD are up-regulated after severe injuries but the source of posttraumatic HBD expression has not been focused on before. In the current study we analysed the role of liver tissue in expression of HBD after multiple trauma in human and mice. HBD-2 expression has been detected in plasma samples of 32 multiple trauma patients (ISS > 16) over 14 days after trauma by ELISA. To investigate major sources of HBD-2, its expression and regulation in plasma samples, polymorphonuclear neutrophils (PMN) and human tissue samples of liver and skin were analysed by ELISA. As liver samples of trauma patients are hard to obtain we tried to review findings in an established trauma model. Plasma samples and liver samples of 56 male C57BL/6 N-mice with a thorax trauma and a femur fracture were analysed by ELISA, real-time PCR and immunohistochemistry for murine beta defensin 4 (MBD-4) and compared with the expression of control group without trauma. The induction of HBD-2 expression in cultured hepatocytes (Hep G2) was analysed after incubation with IL-6, supernatant of Staphylococcus aureus (SA) and Lipopolysaccharides (LPS). One possible signalling pathway was tested by blocking toll-like receptor 2 (TLR2) in hepatocytes. Compared to healthy control group, plasma of multiple traumatized patients and mice showed significantly higher defensin levels after trauma. Compared to skin cells, which are known for high beta defensin expression, liver tissue showed less HBD-2 expression, but higher HBD-2 expression compared to PMN. Immunhistochemical staining demonstrated upregulated MBD-4 in hepatocytes of traumatised mice. In HepG2 cells HBD-2 expression could be increased by stimulation with IL-6 and SA. Neutralization of HepG2 cells with αTLR2 showed reduced HBD-2 expression after stimulation with SA. Plasma samples of multiple traumatized patients showed high expression of HBD-2, which may protect the severely injured patient from overwhelming bacterial infection. Our data support the hypothesis that liver is one possible source for HBD-2 in plasma while posttraumatic inflammatory response.

  7. On-line determination of Sb(III) and total Sb using baker's yeast immobilized on polyurethane foam and hydride generation inductively coupled plasma optical emission spectrometry

    NASA Astrophysics Data System (ADS)

    Menegário, Amauri A.; Silva, Ariovaldo José; Pozzi, Eloísa; Durrant, Steven F.; Abreu, Cassio H.

    2006-09-01

    The yeast Saccharomyces cerevisiae was immobilized in cubes of polyurethane foam and the ability of this immobilized material to separate Sb(III) and Sb(V) was investigated. A method based on sequential determination of total Sb (after on-line reduction of Sb(V) to Sb(III) with thiourea) and Sb(III) (after on-line solid-liquid phase extraction) by hydride generation inductively coupled plasma optical emission spectrometry is proposed. A flow system assembled with solenoid valves was used to manage all stages of the process. The effects of pH, sample loading and elution flow rates on solid-liquid phase extraction of Sb(III) were evaluated. Also, the parameters related to on-line pre-reduction (reaction coil and flow rates) were optimized. Detection limits of 0.8 and 0.15 μg L - 1 were obtained for total Sb and Sb(III), respectively. The proposed method was applied to the analysis of river water and effluent samples. The results obtained for the determination of total Sb were in agreement with expected values, including the river water Standard Reference Material 1640 certified by the National Institute of Standards and Technology (NIST). Recoveries of Sb(III) and Sb(V) in spiked samples were between 81 ± 19 and 111 ±15% when 120 s of sample loading were used.

  8. Using peripheral blood circulating DNAs to detect CpG global methylation status and genetic mutations in patients with myelodysplastic syndrome

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Iriyama, Chisako; Tomita, Akihiro, E-mail: atomita@med.nagoya-u.ac.jp; Hoshino, Hideaki

    2012-03-23

    Highlights: Black-Right-Pointing-Pointer Circulating DNAs (CDs) can be used to detect genetic/epigenetic abnormalities in MDS. Black-Right-Pointing-Pointer Epigenetic changes can be detected more sensitively when using plasma DNA than PBMNC. Black-Right-Pointing-Pointer Mutation ratio in CDs may reflect the ratio in stem cell population in bone marrow. Black-Right-Pointing-Pointer Using CDs can be a safer alternate strategy compared to bone marrow aspiration. -- Abstract: Myelodysplastic syndrome (MDS) is a hematopoietic stem cell disorder. Several genetic/epigenetic abnormalities are deeply associated with the pathogenesis of MDS. Although bone marrow (BM) aspiration is a common strategy to obtain MDS cells for evaluating their genetic/epigenetic abnormalities, BM aspirationmore » is difficult to perform repeatedly to obtain serial samples because of pain and safety concerns. Here, we report that circulating cell-free DNAs from plasma and serum of patients with MDS can be used to detect genetic/epigenetic abnormalities. The plasma DNA concentration was found to be relatively high in patients with higher blast cell counts in BM, and accumulation of DNA fragments from mono-/di-nucleosomes was confirmed. Using serial peripheral blood (PB) samples from patients treated with hypomethylating agents, global methylation analysis using bisulfite pyrosequencing was performed at the specific CpG sites of the LINE-1 promoter. The results confirmed a decrease of the methylation percentage after treatment with azacitidine (days 3-9) using DNAs from plasma, serum, and PB mono-nuclear cells (PBMNC). Plasma DNA tends to show more rapid change at days 3 and 6 compared with serum DNA and PBMNC. Furthermore, the TET2 gene mutation in DNAs from plasma, serum, and BM cells was quantitated by pyrosequencing analysis. The existence ratio of mutated genes in plasma and serum DNA showed almost equivalent level with that in the CD34+/38- stem cell population in BM. These data suggest that genetic/epigenetic analyses using PB circulating DNA can be a safer and painless alternative to using BM cells.« less

  9. Multiplex KRASG12/G13 mutation testing of unamplified cell-free DNA from the plasma of patients with advanced cancers using droplet digital polymerase chain reaction.

    PubMed

    Janku, F; Huang, H J; Fujii, T; Shelton, D N; Madwani, K; Fu, S; Tsimberidou, A M; Piha-Paul, S A; Wheler, J J; Zinner, R G; Naing, A; Hong, D S; Karp, D D; Cabrilo, G; Kopetz, E S; Subbiah, V; Luthra, R; Kee, B K; Eng, C; Morris, V K; Karlin-Neumann, G A; Meric-Bernstam, F

    2017-03-01

    Cell-free DNA (cfDNA) from plasma offers easily obtainable material for KRAS mutation analysis. Novel, multiplex, and accurate diagnostic systems using small amounts of DNA are needed to further the use of plasma cfDNA testing in personalized therapy. Samples of 16 ng of unamplified plasma cfDNA from 121 patients with diverse progressing advanced cancers were tested with a KRASG12/G13 multiplex assay to detect the seven most common mutations in the hotspot of exon 2 using droplet digital polymerase chain reaction (ddPCR). The results were retrospectively compared to mutation analysis of archival primary or metastatic tumor tissue obtained at different points of clinical care. Eighty-eight patients (73%) had KRASG12/G13 mutations in archival tumor specimens collected on average 18.5 months before plasma analysis, and 78 patients (64%) had KRASG12/G13 mutations in plasma cfDNA samples. The two methods had initial overall agreement in 103 (85%) patients (kappa, 0.66; ddPCR sensitivity, 84%; ddPCR specificity, 88%). Of the 18 discordant cases, 12 (67%) were resolved by increasing the amount of cfDNA, using mutation-specific probes, or re-testing the tumor tissue, yielding overall agreement in 115 patients (95%; kappa 0.87; ddPCR sensitivity, 96%; ddPCR specificity, 94%). The presence of ≥ 6.2% of KRASG12/G13 cfDNA in the wild-type background was associated with shorter survival (P = 0.001). Multiplex detection of KRASG12/G13 mutations in a small amount of unamplified plasma cfDNA using ddPCR has good sensitivity and specificity and good concordance with conventional clinical mutation testing of archival specimens. A higher percentage of mutant KRASG12/G13 in cfDNA corresponded with shorter survival. © The Author 2016. Published by Oxford University Press on behalf of the European Society for Medical Oncology. All rights reserved. For permissions, please email: journals.permissions@oup.com.

  10. Degradation and Stabilization of Peptide Hormones in Human Blood Specimens

    PubMed Central

    Yi, Jizu; Warunek, David; Craft, David

    2015-01-01

    Plasma hormone peptides, including GLP-1, GIP, Glucagon, and OXM, possess multiple physiological roles and potential therapeutic and diagnostic utility as biomarkers in the research of metabolic disorders. These peptides are subject to proteolytic degradation causing preanalytical variations. Stabilization for accurate quantitation of these active peptides in ex vivo blood specimens is essential for drug and biomarker development. We investigated the protease-driven instability of these peptides in conventional serum, plasma, anticoagulated whole blood, as well as whole blood and plasma stabilized with protease inhibitors. The peptide was monitored by both time-course Matrix-Assisted Laser Desorption Ionization Time-to-Flight Mass Spectrometry (MALDI –TOF MS) and Ab-based assay (ELISA or RIA). MS enabled the identification of proteolytic fragments. In non-stabilized blood samples, the results clearly indicated that dipeptidyl peptidase-IV (DPP-IV) removed the N-terminal two amino acid residues from GLP-1, GIP and OXM(1-37) and not-yet identified peptidase(s) cleave(s) the full-length OXM(1-37) and its fragments. DPP-IV also continued to remove two additional N-terminal residues of processed OXM(3–37) to yield OXM(5–37). Importantly, both DPP-IV and other peptidase(s) activities were inhibited efficiently by the protease inhibitors included in the BD P800* tube. There was preservation of GLP-1, GIP, OXM and glucagon in the P800 plasma samples with half-lives > 96, 96, 72, and 45 hours at room temperature (RT), respectively. In the BD P700* plasma samples, the stabilization of GLP-1 was also achieved with half-life > 96 hours at RT. The stabilization of these variable peptides increased their utility in drug and/or biomarker development. While stability results of GLP-1 obtained with Ab-based assay were consistent with those obtained by MS analysis, the Ab-based results of GIP, Glucagon, and OXM did not reflect the time-dependent degradations revealed by MS analysis. Therefore, we recommended characterizing the degradation of the peptide using the MS-based method when investigating the stability of a specific peptide. PMID:26222180

  11. Mechanically induced self-propagating reaction and consequent consolidation for the production of fully dense nanocrystalline Ti{sub 55}C{sub 45} bulk material

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sherif El-Eskandarany, M., E-mail: msherif@kisr.edu.kw; Al-Hazza, Abdulsalam

    2014-11-15

    We employed a high-energy ball mill for the synthesis of nanograined Ti{sub 55}C{sub 45} powders starting from elemental Ti and C powders. The mechanically induced self-propagating reaction that occurred between the reactant materials was monitored via a gas atmosphere gas-temperature-monitoring system. A single phase of NaCl-type TiC was obtained after 5 h of ball milling. To decrease the powder and grain sizes, the material was subjected to further ball milling time. The powders obtained after 200 h of milling possessed spherical-like morphology with average particle and grain sizes of 45 μm and 4.2 nm, respectively. The end-products obtained after 200more » h of ball milling time, were then consolidated into full dense compacts, using hot pressing and spark plasma sintering at 1500 and 34.5 MPa, with heating rates of 20 °C/min and 500 °C/min, respectively. Whereas hot pressing of the powders led to severe grain growth (∼ 436 nm in diameter), the as-spark plasma sintered powders maintained their nanograined characteristics (∼ 28 nm in diameter). The as-synthesized and as-consolidated powders were characterized, using X-ray diffraction, high-resolution electron microscopy, and scanning electron microscopy. The mechanical properties of the consolidated samples obtained via the hot pressing and spark plasma sintering techniques were characterized, using Vickers microhardness and non-destructive testing techniques. The Vickers hardness, Young's modulus, shear modulus and fracture toughness of as-spark plasma sintered samples were 32 GPa, 358 GPa, 151 GPa and 6.4 MPa·m{sup 1/2}, respectively. The effects of the consolidation approach on the grain size and mechanical properties were investigated and are discussed. - Highlights: • Room-temperature synthesizing of NaCl-type TiC • Dependence on the grain size on the ball milling time • Fabrication of equiaxed nanocrystalline grains with a diameter of 4.2 nm • Fabrication of nanocrystalline bulk TiC material by SPS with minimal grain growth • Dependence of improved mechanical properties on the consolidation techniques.« less

  12. Single-sample 99mTc-diethylenetriamine penta-acetate plasma clearance in advanced renal failure by the mean sojourn time approach.

    PubMed

    Gref, Margareta C; Karp, Kjell H

    2009-03-01

    The single-sample Tc-diethylenetriamine penta-acetate (DTPA) clearance method by Christensen and Groth is recommended by the Radionuclides in Nephrourology Committee on Renal Clearance for use in adults with an estimated glomerular filtration rate (GFR) > or = 30 ml/min. The purpose of this study was to test a new Tc-DTPA single-sample low clearance formula for GFR lesser than 30 ml/min. Twenty-one adult patients (29 investigations) were included. Reference clearance was calculated with both Cr-EDTA and Tc-DTPA according to Brøchner-Mortensen with samples drawn between 3 and 24 h. Single-sample clearance was calculated from a 24 h sample using the low clearance formula(Equation is included in full-text article.) C(t) is the activity of the tracer in the plasma sample t minutes after the injection and Q0 is the injected amount. ECV is the extracellular volume in ml defined as the distribution volume of the tracer. ECV is estimated from the body surface area as ECV=8116.6xbody surface area-28.2. The mean difference between reference and Tc-DTPA single-sample clearance was -0.5 ml/min (SD 1.0 ml/min) for Tc-DTPA and -0.8 ml/min (SD 1.2 ml/min) for Cr-EDTA as reference clearance. In adult patients it is possible, even with GFR lesser than 30 ml/min, to get an accurate determination of Tc-DTPA plasma clearance from a single sample using the mean sojourn time approach. The blood sample should be obtained about 24 h after injection of the GFR tracer.

  13. Casingless down-hole for sealing an ablation volume and obtaining a sample for analysis

    DOEpatents

    Noble, Donald T.; Braymen, Steven D.; Anderson, Marvin S.

    1996-10-01

    A casing-less down hole sampling system for acquiring a subsurface sample for analysis using an inductively coupled plasma system is disclosed. The system includes a probe which is pushed into the formation to be analyzed using a hydraulic ram system. The probe includes a detachable tip member which has a soil point mad a barb, with the soil point aiding the penetration of the earth, and the barb causing the tip member to disengage from the probe and remain in the formation when the probe is pulled up. The probe is forced into the formation to be tested, and then pulled up slightly, to disengage the tip member and expose a column of the subsurface formation to be tested. An instrumentation tube mounted in the probe is then extended outward from the probe to longitudinally extend into the exposed column. A balloon seal mounted on the end of the instrumentation tube allows the bottom of the column to be sealed. A source of laser radiation is emitted from the instrumentation tube to ablate a sample from the exposed column. The instrumentation tube can be rotated in the probe to sweep the laser source across the surface of the exposed column. An aerosol transport system carries the ablated sample from the probe to the surface for testing in an inductively coupled plasma system. By testing at various levels in the down-hole as the probe is extracted from the soil, a profile of the subsurface formation may be obtained.

  14. Elemental profiling of Noah's Ark shell (Arca noae, Linnaeus, 1758) by plasma optical spectrometry and chemometric tools.

    PubMed

    Kobelja, Kristina; Nemet, Ivan; Župan, Ivan; Čulin, Jelena; Rončević, Sanda

    2016-12-01

    Determination of metal content in biominerals provides essential information with respect to relations between biomineralization processes and environmental status. Mussels are species that have a great potential as bio-marker species and therefore, they are in the focus of numerous biomineralization and ecological studies. In this study, elemental profile of mussel shell of Noah's Ark (Arca noe, Linnaeus, 1758), which inhabit eastern Adriatic Sea was obtained by determination of seventeen elements content using inductively coupled plasma optical emission spectrometry (ICP-OES). Shell samples were collected from marine protected area and from marine shipping route in eastern Adriatic Sea. The accuracy of applied analytical procedure based on microwave decomposition of shell samples was tested by use of reference materials of limestone and by matrix-matched standards. By aid of chemometric methods, the elemental profile along with variability of elements content of shell was obtained. The impact of different environment on elements content was established by use of multivariate statistical PCA method. Discernment between two groups of samples was manifested. Among results of main, minor and trace elements content, the last one which denoted to Cd, Co, Cu, Pb, and Mn was expressed as principal distinctive feature of shell samples collected from different sampling sites. Elemental profiling of mussel shell Noah's Ark provides novel insight in species status as well as in environmental status on the observed locations. Copyright © 2016 Elsevier GmbH. All rights reserved.

  15. Modified ion exchange separation for tungsten isotopic measurements from kimberlite samples using multi-collector inductively coupled plasma mass spectrometry.

    PubMed

    Sahoo, Yu Vin; Nakai, Shun'ichi; Ali, Arshad

    2006-03-01

    Tungsten isotope composition of a sample of deep-seated rock can record the influence of core-mantle interaction of the parent magma. Samples of kimberlite, which is known as a carrier of diamond, from the deep mantle might exhibit effects of core-mantle interaction. Although tungsten isotope anomaly was reported for kimberlites from South Africa, a subsequent investigation did not verify the anomaly. The magnesium-rich and calcium-rich chemical composition of kimberlite might engender difficulty during chemical separation of tungsten for isotope analyses. This paper presents a simple, one-step anion exchange technique for precise and accurate determination of tungsten isotopes in kimberlites using multi-collector inductively coupled plasma mass spectrometry (MC-ICP-MS). Large quantities of Ca and Mg in kimberlite samples were precipitated and removed with aqueous H(2)SO(4). Highly pure fractions of tungsten for isotopic measurements were obtained following an anion exchange chromatographic procedure involving mixed acids. That procedure enabled efficient removal of high field strength elements (HFSE), such as Hf, Zr and Ti, which are small ions that carry strong charges and develop intense electrostatic fields. The tungsten yields were 85%-95%. Advantages of this system include less time and less use of reagents. Precise and accurate isotopic measurements are possible using fractions of tungsten that are obtained using this method. The accuracy and precision of these measurements were confirmed using various silicate standard rock samples, JB-2, JB-3 and AGV-1.

  16. Parametric study of a fiber-optic laser-induced breakdown spectroscopy probe for analysis of aluminum alloys

    NASA Astrophysics Data System (ADS)

    Rai, Awadhesh K.; Zhang, Hansheng; Yueh, Fang Yu; Singh, Jagdish P.; Weisberg, Arel

    2001-12-01

    In the present work we demonstrate a fiber-optic laser-induced breakdown spectroscopy (FO LIBS) system for delivering laser energy to a sample surface to produce a spark as well as to collect the resulting radiation from the laser-induced spark. In order to improve the signal/background (S/B) ratio, various experimental parameters, such as laser energy, gate delay and width, detector gain, lenses of different focal lengths and sample surface, were tested. In order to provide high reliability and repeatability in the analysis, we also measured plasma parameters, such as electron density and plasma temperature, and determined their influence on the measurement results. The performance of FO LIBS was also compared with that of a LIBS system that does not use a fiber to transmit the laser beam. LIBS spectra with a good S/B were recorded at 2-μs gate delay and width. LIBS spectra of six different Al alloy samples were recorded to obtain calibration data. We were able to obtain linear calibration data for numerous elements (Cr, Zn, Fe, Ni, Mn, Mg and Cu). A linear calibration curve for LIBS intensity ratio vs. concentration ratio reduces the effect of physical variables (i.e. shot-to-shot power fluctuation, sample-to-surface distance, and physical properties of the samples). Our results reveal that this system may be useful in designing a high-temperature LIBS probe for measuring the elemental composition of Al melt.

  17. Plasma magnesium concentration in patients undergoing coronary artery bypass grafting.

    PubMed

    Kotlinska-Hasiec, Edyta; Makara-Studzinska, Marta; Czajkowski, Marek; Rzecki, Ziemowit; Olszewski, Krzysztof; Stadnik, Adam; Pilat, Jacek; Rybojad, Beata; Dabrowski, Wojciech

    2017-05-11

    [b]Introduction[/b]. Magnesium (Mg) plays a crucial role in cell physiology and its deficiency may cause many disorders which often require intensive treatment. The aim of this study was to analyse some factors affecting preoperative plasma Mg concentration in patients undergoing coronary artery bypass grafting (CABG). [b]Materials and method[/b]. Adult patients scheduled for elective CABG with cardio-pulmonary bypass (CPB) under general anaesthesia were studied. Plasma Mg concentration was analysed before surgery in accordance with age, domicile, profession, tobacco smoking and preoperative Mg supplementation. Blood samples were obtained from the radial artery just before the administration of anaesthesia. [b]Results. [/b]150 patients were studied. Mean preoperative plasma Mg concentration was 0.93 ± 0.17 mmol/L; mean concentration in patients - 1.02 ± 0.16; preoperative Mg supplementation was significantly higher than in patients without such supplementation. Moreover, intellectual workers supplemented Mg more frequently and had higher plasma Mg concentration than physical workers. Plasma Mg concentration decreases in elderly patients. Patients living in cities, on average, had the highest plasma Mg concentration. Smokers had significantly lower plasma Mg concentration than non-smokers. [b]Conclusions. [/b]1. Preoperative magnesium supplementation increases its plasma concentration. 2. Intellectual workers frequently supplement magnesium. 3. Smoking cigarettes decreases plasma magnesium concentration.

  18. Liquid chromatography tandem mass spectrometry method for the quantitative analysis of ceritinib in human plasma and its application to pharmacokinetic studies.

    PubMed

    Heudi, Olivier; Vogel, Denise; Lau, Yvonne Y; Picard, Franck; Kretz, Olivier

    2014-11-01

    Ceritinib is a highly selective inhibitor of an important cancer target, anaplastic lymphoma kinase (ALK). Because it is an investigational compound, there is a need to develop a robust and reliable analytical method for its quantitative determination in human plasma. Here, we report the validation of a liquid chromatography tandem mass spectrometry (LC-MS/MS) method for the rapid quantification of ceritinib in human plasma. The method consists of protein precipitation with acetonitrile, and salting-out assisted liquid-liquid extraction (SALLE) using a saturated solution of sodium chloride prior to analysis by LC-MS/MS with electrospray ionization (ESI) technique in positive mode. Samples were eluted at 0.800 mL min(-1) on Ascentis Express® C18 column (50 mm × 2.1 mm, 2.7 μm) with a mobile phase made of 0.1 % formic acid in water (A) and 0.1 % formic acid in acetonitrile (B). The method run time was 3.6 min and the low limit of quantification (LLOQ) was estimated at 1.00 ng mL(-1) when using 0.100 mL of human plasma. The assay was fully validated and the method exhibited sufficient specificity, accuracy, precision, and sensitivity. In addition, recovery data and matrix factor (MF) in normal and in hemolyzed plasmas were assessed, while incurred samples stability (ISS) for ceritinib was demonstrated for at least 21 months at a storage temperature of -65 °C or below. The method was successfully applied to the measurement of ceritinib in clinical samples and the data obtained on incurred samples reanalysis (ISR) showed that our method was reliable and suitable to support the analysis of samples from the clinical studies.

  19. Metal surface nitriding by laser induced plasma

    NASA Astrophysics Data System (ADS)

    Thomann, A. L.; Boulmer-Leborgne, C.; Andreazza-Vignolle, C.; Andreazza, P.; Hermann, J.; Blondiaux, G.

    1996-10-01

    We study a nitriding technique of metals by means of laser induced plasma. The synthesized layers are composed of a nitrogen concentration gradient over several μm depth, and are expected to be useful for tribological applications with no adhesion problem. The nitriding method is tested on the synthesis of titanium nitride which is a well-known compound, obtained at present by many deposition and diffusion techniques. In the method of interest, a laser beam is focused on a titanium target in a nitrogen atmosphere, leading to the creation of a plasma over the metal surface. In order to understand the layer formation, it is necessary to characterize the plasma as well as the surface that it has been in contact with. Progressive nitrogen incorporation in the titanium lattice and TiN synthesis are studied by characterizing samples prepared with increasing laser shot number (100-4000). The role of the laser wavelength is also inspected by comparing layers obtained with two kinds of pulsed lasers: a transversal-excited-atmospheric-pressure-CO2 laser (λ=10.6 μm) and a XeCl excimer laser (λ=308 nm). Simulations of the target temperature rise under laser irradiation are performed, which evidence differences in the initial laser/material interaction (material heated thickness, heating time duration, etc.) depending on the laser features (wavelength and pulse time duration). Results from plasma characterization also point out that the plasma composition and propagation mode depend on the laser wavelength. Correlation of these results with those obtained from layer analyses shows at first the important role played by the plasma in the nitrogen incorporation. Its presence is necessary and allows N2 dissociation and a better energy coupling with the target. Second, it appears that the nitrogen diffusion governs the nitriding process. The study of the metal nitriding efficiency, depending on the laser used, allows us to explain the differences observed in the layer features as purity, thickness, and surface morphology.

  20. [Characteristic of sample banks isolated from EDTA-blood by sedimentation method].

    PubMed

    Chen, Zhi-bin; Lin, Qin; Ma, Chang-hua; Liu, Kai-ning; Meng, Huan-xin

    2014-02-18

    To assess the characteristics of establishing the different sample banks of plasma, leukocytes and DNA by sedimentation method of isolating from ethylene diamine tetraacetic acid(EDTA)-blood and to clarify the sedimentation method of leukocyte isolation and plasma volume by comparative data and recommended procedures for applicability. In the study, 29 EDTA-bloods were obtained, the total amounts of leukocytes and the percentage of neutrophile granulocytes, and lymphocytes in the EDTA-blood detected as a control group and then assigned equally into 4 EP tubes with 1 mL EDTA-blood per tube as 4 test groups, then the 4 tubes were placed with the EDTA-blood at room temperature and the plasma layers were isolated at 0.5, 1, 2 and 3 h, receptively. The total amount of leukocytes and the percentage of neutrophile granulocytes, and lymphocytes were detected by automated hematology analyzer at the clinical laboratory. The volume of the plasma was also measured at the same time. The plasma volume at 0.5 h [(241.72 ± 101.52)μL] was substantially lower than those at 1 h[(317.24 ± 97.50)μL], at 2 h[(371.03 ± 91.66)μL], and at 3 h [(408.97 ± 97.43)μL] , P < 0.05. The plasma volume at 1 h was substantially lower than those at 2 h and 3 h (P < 0.05). The total amount of leukocytes in the plasma layer at 0.5 h (2.50 × 10(6) ± 1.48 × 10(6)) group was substantially higher than the amount of 2 or 3 h groups respectively (1.47 × 10(6) ± 7.19 × 105,1.21 × 10(6) ± 7.41 × 105), P < 0.05. Significant difference was not found between 0.5 h group and 1 h group (2.29 × 10(6)± 1.17 × 10(6)), P > 0.05. The total amount of leukocytes in the plasma layer in 1 h group was substantially higher than that in 2 h and 3 h groups (P < 0.05). There was no significant difference between 3 h group and 2 h group (P > 0.05). The total amount of leukocytes in the plasma layer of the 4 test groups was substantially lower than that in the control group (P < 0.05). The percentage of neutrophile granulocytes (54.14% ± 11.65%) in the plasma layer in 0.5 h group was substantially higher than those in 1 h, 2 h and 3 h groups (46.66% ± 12.70%,39.17% ± 12.33%,43.25% ± 14.54%), P < 0.05, respectively, which was the substantially lower than that in the control group (60.53% ± 8.46%), P < 0.05. The average value of the percentage of neutrophile granulocytes in the plasma layer in 1 h group was substantially higher than that in 2 h group (P < 0.05). There was no significant different between 3 h group and both 1 h, 2 h groups (P > 0.05). The mean percentage of lymphocytes in the plasma layer in 0.5 h group (35.09% ± 10.84%) was substantially lower than those in the plasma layer in 1 h, 2 h and 3 h groups, respectively ( 41.48% ± 12.20%, 47.96% ± 12.27%, 45.50% ± 13.71%), which was significant higher than that in the control group(30.98% ± 7.33%), P < 0.05. The average value of the percentage of lymphocytes in the plasma layer in 1 h group was substantially higher than those in the control group and 0.5 h group, but was substantially lower than those in 2 h and 3 h groups (P < 0.05). The average value of percentage of lymphocytes in the plasma layer in 2 h group was substantially higher than those in the control group, 0.5 h and 1 h groups (P < 0.05). There was no significant difference between 2 h and 3 h groups (P > 0.05). The best period of time in obtaining leukocytes is 0.5-1 h sedimentation of EDTA-blood. Both the plasma layer and leukocytes can be separated and obtained at the same time from the same sample by the sedimentation method of EDTA-blood. The sedimentation of EDTA-blood has the least interference of both chemical and physical factors, as well as a ready operation, which can establish the plasma, leukocytes and DNA sample banks for various aspects of research.

  1. Plasma heating for containerless and microgravity materials processing

    NASA Technical Reports Server (NTRS)

    Leung, Emily W. (Inventor); Man, Kin F. (Inventor)

    1994-01-01

    A method for plasma heating of levitated samples to be used in containerless microgravity processing is disclosed. A sample is levitated by electrostatic, electromagnetic, aerodynamic, or acoustic systems, as is appropriate for the physical properties of the particular sample. The sample is heated by a plasma torch at atmospheric pressure. A ground plate is provided to help direct the plasma towards the sample. In addition, Helmholtz coils are provided to produce a magnetic field that can be used to spiral the plasma around the sample. The plasma heating system is oriented such that it does not interfere with the levitation system.

  2. Reduction of interferences in graphite furnace atomic absorption spectrometry by multiple linear regression modelling

    NASA Astrophysics Data System (ADS)

    Grotti, Marco; Abelmoschi, Maria Luisa; Soggia, Francesco; Tiberiade, Christian; Frache, Roberto

    2000-12-01

    The multivariate effects of Na, K, Mg and Ca as nitrates on the electrothermal atomisation of manganese, cadmium and iron were studied by multiple linear regression modelling. Since the models proved to efficiently predict the effects of the considered matrix elements in a wide range of concentrations, they were applied to correct the interferences occurring in the determination of trace elements in seawater after pre-concentration of the analytes. In order to obtain a statistically significant number of samples, a large volume of the certified seawater reference materials CASS-3 and NASS-3 was treated with Chelex-100 resin; then, the chelating resin was separated from the solution, divided into several sub-samples, each of them was eluted with nitric acid and analysed by electrothermal atomic absorption spectrometry (for trace element determinations) and inductively coupled plasma optical emission spectrometry (for matrix element determinations). To minimise any other systematic error besides that due to matrix effects, accuracy of the pre-concentration step and contamination levels of the procedure were checked by inductively coupled plasma mass spectrometric measurements. Analytical results obtained by applying the multiple linear regression models were compared with those obtained with other calibration methods, such as external calibration using acid-based standards, external calibration using matrix-matched standards and the analyte addition technique. Empirical models proved to efficiently reduce interferences occurring in the analysis of real samples, allowing an improvement of accuracy better than for other calibration methods.

  3. Temporal and spatial dynamics of optical emission from laser ablation of the first wall materials of fusion device

    NASA Astrophysics Data System (ADS)

    Dongye, ZHAO; Cong, LI; Yong, WANG; Zhiwei, WANG; Liang, GAO; Zhenhua, HU; Jing, WU; Guang-Nan, LUO; Hongbin, DING

    2018-01-01

    Laser-induced breakdown spectroscopy (LIBS) has been developed to in situ diagnose the chemical compositions of the first wall in the EAST tokamak. However, the dynamics of optical emission of the key plasma-facing materials, such as tungsten, molybdenum and graphite have not been investigated in a laser produced plasma (LPP) under vacuum. In this work, the temporal and spatial dynamics of optical emission were investigated using the spectrometer with ICCD. Plasma was produced by an Nd:YAG laser (1064 nm) with pulse duration of 6 ns. The results showed that the typical lifetime of LPP is less than 1.4 μs, and the lifetime of ions is shorter than atoms at ˜10-6 mbar. Temporal features of optical emission showed that the optimized delay times for collecting spectra are from 100 to 400 ns which depended on the corresponding species. For spatial distribution, the maximum LIBS spectral intensity in plasma plume is obtained in the region from 1.5 to 3.0 mm above the sample surface. Moreover, the plasma expansion velocity involving the different species in a multicomponent system was measured for obtaining the proper timing (gate delay time and gate width) of the maximum emission intensity and for understanding the plasma expansion mechanism. The order of expansion velocities for various species is {V}{{{C}}+}> {V}{{H}}> {V}{{{Si}}+}> {V}{{Li}}> {V}{{Mo}}> {V}{{W}}. These results could be attributed to the plasma sheath acceleration and mass effect. In addition, an optimum signal-to-background ratio was investigated by varying both delay time and detecting position.

  4. Modeling of Plasma Assisted Combustion

    NASA Astrophysics Data System (ADS)

    Akashi, Haruaki

    2012-10-01

    Recently, many experimental study of plasma-assisted combustion has been done. However, numerous complex reactions in combustion of hydrocarbons are preventing from theoritical study for clarifying inside the plasma-assisted combustion, and the effect of plasma-assist is still not understood. Shinohara and Sasaki [1,2] have reported that the shortening of flame length by irradiating microwave without increase of gas temperature. And they also reported that the same phenomena would occur when applying dielectric barrier discharges to the flame using simple hydrocarbon, methane. It is suggested that these phenomena may result by the electron heating. To clarify this phenomena, electron behavior under microwave and DBD was examined. For the first step of DBD plasma-assisted combustion simulation, electron Monte Carlo simulation in methane, oxygen and argon mixture gas(0.05:0.14:0.81) [2] has been done. Electron swarm parameters are sampled and electron energy distribution function (EEDF)s are also determined. In the combustion, gas temperature is higher(>1700K), so reduced electric field E/N becomes relatively high(>10V/cm/Torr). The electrons are accelerated to around 14 eV. This result agree with the optical emission from argon obtained by the experiment of reference [2]. Dissociation frequency of methane and oxygens are obtained in high. This might be one of the effect of plasma-assist. And it is suggested that the electrons should be high enough to dissociate methane, but plasma is not needed.[4pt] [1] K. Shinohara et al, J. Phys. D:Appl. Phys., 42, 182008 (1-7) (2009).[0pt] [2] K. Sasaki, 64th Annual Gaseous Electronic Conference, 56, 15 CT3.00001(2011).

  5. Rapid measurement of fibrinogen concentration in whole blood using a steel ball coagulometer

    PubMed Central

    Schlimp, Christoph J.; Khadem, Anna; Klotz, Anton; Solomon, Cristina; Hochleitner, Gerald; Ponschab, Martin; Redl, Heinz; Schöchl, Herbert

    2015-01-01

    BACKGROUND Fibrinogen plays a key role in hemostasis and is the first coagulation factor to reach critical levels in bleeding patients. Current European guidelines on the management of traumatic or perioperative bleeding recommend fibrinogen supplementation at specific threshold levels. Whole blood viscoelastic tests provide fast evaluation of fibrin deficits. Fast measurement of plasma fibrinogen concentration is not yet available. We investigated a method to rapidly determine whole blood fibrinogen concentration using standard Clauss assays and a steel ball coagulometer and provide an estimate of the “plasma-equivalent” fibrinogen concentration within minutes by adjustment of the measured whole blood fibrinogen concentration with a quickly measureable hemoglobin-derived hematocrit. METHODS The feasibility of this approach was tested with a Clauss assay using multiple porcine fresh blood samples obtained during in vivo bleeding, hemodilution, and after treatment with hemostatic therapy. Two different Clauss assays were then tested using multiple human volunteers’ blood samples diluted in vitro and supplemented with fibrinogen concentrate. Comparative measurements with fibrin-based thromboelastometry tests were performed. RESULTS Regression and Bland-Altman analyses of derived “plasma-equivalent” fibrinogen and measured plasma fibrinogen concentration was excellent in porcine and human blood samples, especially in the ranges relevant to traumatic or perioperative bleeding. CONCLUSION Fast whole blood fibrinogen measurements could be considered as an alternative to plasma fibrinogen measurement for acute bleeding management in trauma and perioperative care settings. Further studies are needed to prove this concept and determine the turnaround times for its clinical application in emergency departments and operating theaters. PMID:25742256

  6. A simple graphene-based pipette tip solid-phase extraction of malondialdehyde from human plasma and its determination by spectrofluorometry.

    PubMed

    Kaykhaii, Massoud; Yahyavi, Hossain; Hashemi, Mohammad; Khoshroo, Mohammad Reza

    2016-07-01

    Determination of malondialdehyde (MDA) in human blood plasma is important because of its role as a biomarker of lipid peroxidation in biological and medical sciences. In this work, a miniaturized graphene-based pipette tip solid-phase extraction technique was developed for very efficient extraction of MDA as its dithiobarbituric acid (TBA) adduct from human plasma. Two milligrams of graphene as sorbent were placed into a pipette tip and MDA-TBA compound was extracted and preconcentrated by it, after 4 repeated aspirating/dispensing cycles, then the column was eluted with 80 μL of dimethyl sulfoxide by 4 repeated aspirating/dispensing cycles and elusion was measured spectrofluorimetrically. Various effective parameters such as type and volume of eluent solvent, temperature, sample volume, number of cycles of extraction and desorption, derivatization reaction time, and pH of the sample solution were investigated and optimized. Under optimum conditions, a linear calibration curve was obtained in the range of 0.5-90 μg L(-1) (r (2) = 0.991) with a detection limit of 0.3 μg L(-1). The relative standard deviations for 8 replicate measurements of 10 and 40 μg L(-1) of MDA were found to be 4.51 and 3.78 % respectively. The developed protocol was successfully applied to the determination of MDA in a human blood plasma sample. Graphical Abstract A simple graphene-based pipette tip solid-phase extraction of malondialdehyde from human plasma and its determination by spectrofluorometry.

  7. Development and Validation of Limited-Sampling Strategies for Predicting Amoxicillin Pharmacokinetic and Pharmacodynamic Parameters

    PubMed Central

    Suarez-Kurtz, Guilherme; Ribeiro, Frederico Mota; Vicente, Flávio L.; Struchiner, Claudio J.

    2001-01-01

    Amoxicillin plasma concentrations (n = 1,152) obtained from 48 healthy subjects in two bioequivalence studies were used to develop limited-sampling strategy (LSS) models for estimating the area under the concentration-time curve (AUC), the maximum concentration of drug in plasma (Cmax), and the time interval of concentration above MIC susceptibility breakpoints in plasma (T>MIC). Each subject received 500-mg amoxicillin, as reference and test capsules or suspensions, and plasma concentrations were measured by a validated microbiological assay. Linear regression analysis and a “jack-knife” procedure revealed that three-point LSS models accurately estimated (R2, 0.92; precision, <5.8%) the AUC from 0 h to infinity (AUC0-∞) of amoxicillin for the four formulations tested. Validation tests indicated that a three-point LSS model (1, 2, and 5 h) developed for the reference capsule formulation predicts the following accurately (R2, 0.94 to 0.99): (i) the individual AUC0-∞ for the test capsule formulation in the same subjects, (ii) the individual AUC0-∞ for both reference and test suspensions in 24 other subjects, and (iii) the average AUC0-∞ following single oral doses (250 to 1,000 mg) of various amoxicillin formulations in 11 previously published studies. A linear regression equation was derived, using the same sampling time points of the LSS model for the AUC0-∞, but using different coefficients and intercept, for estimating Cmax. Bioequivalence assessments based on LSS-derived AUC0-∞'s and Cmax's provided results similar to those obtained using the original values for these parameters. Finally, two-point LSS models (R2 = 0.86 to 0.95) were developed for T>MICs of 0.25 or 2.0 μg/ml, which are representative of microorganisms susceptible and resistant to amoxicillin. PMID:11600352

  8. Energetics of endurance exercise in young horses determined by nuclear magnetic resonance metabolomics

    PubMed Central

    Luck, Margaux M.; Le Moyec, Laurence; Barrey, Eric; Triba, Mohamed N.; Bouchemal, Nadia; Savarin, Philippe; Robert, Céline

    2015-01-01

    Long-term endurance exercise severely affects metabolism in both human and animal athletes resulting in serious risk of metabolic disorders during or after competition. Young horses (up to 6 years old) can compete in races up to 90 km despite limited scientific knowledge of energetic metabolism responses to long distance exercise in these animals. The hypothesis of this study was that there would be a strong effect of endurance exercise on the metabolomic profiles of young horses and that the energetic metabolism response in young horses would be different from that of more experienced horses. Metabolomic profiling is a powerful method that combines Nuclear Magnetic Resonance (NMR) spectrometry with supervised Orthogonal Projection on Latent Structure (OPLS) statistical analysis. 1H-NMR spectra were obtained from plasma samples drawn from young horses (before and after competition). The spectra obtained before and after the race from the same horse (92 samples) were compared using OPLS. The statistical parameters showed the robustness of the model (R2Y = 0.947, Q2Y = 0.856 and cros-validated ANOVA p < 0.001). For confirmation of the predictive value of the model, a test set of 104 sample spectra were projected by the model, which provided perfect predictions as the area under the receiving-operator curve was 1. The metabolomic profile determined with the OPLS model showed that glycemia after the race was lower than glycemia before the race, despite the involvement of lipid and protein catabolism. An OPLS model was calculated to compare spectra obtained on plasma taken after the race from 6-year-old horses and from experienced horses (cross-validated ANOVA p < 0.001). The comparison of metabolomic profiles in young horses to those from experienced horses showed that experienced horses maintained their glycemia with higher levels of lactate and a decrease of plasma lipids after the race. PMID:26347654

  9. Kinetics and intrapulmonary disposition of tilmicosin after single and repeated oral bolus administrations to rabbits.

    PubMed

    Gallina, G; Lucatello, L; Drigo, I; Cocchi, M; Scandurra, S; Agnoletti, F; Montesissa, C

    2010-06-01

    Tilmicosin (TIM, Pulmotil) was administered to eight rabbits by oral gavage at a dose of 12.5 mg/kg body weight for 2, 5, and 7 days, and its plasma kinetics and intrapulmonary disposition were investigated. TIM concentrations in plasma samples collected after days 1 and 6 of treatment were measured by high-performance liquid chromatography with ultraviolet detection. The pharmacokinetic parameters, obtained by non-compartmental analysis of TIM plasma concentrations, did not show any significant variations between days 1 and 6. From the second day of treatment, TIM concentrations attained in lung tissue and pulmonary alveolar macrophages (PAM) exceeded those in plasma by 7- and 400-fold, respectively, and high levels were maintained in lung tissues during the entire treatment duration. After the first day of withdrawal, a fast decline in TIM levels in both plasma and lung tissue was observed, but in PAM, much higher concentrations were maintained after 3 days of TIM withdrawal.

  10. Canine adiponectin: cDNA structure, mRNA expression in adipose tissues and reduced plasma levels in obesity.

    PubMed

    Ishioka, K; Omachi, A; Sagawa, M; Shibata, H; Honjoh, T; Kimura, K; Saito, M

    2006-04-01

    Adiponectin is a protein synthesized and secreted by adipocytes. Decreased adiponectin is responsible for insulin resistance and atherosclerosis associated with human obesity. We obtained a cDNA clone corresponding to canine adiponectin, whose nucleotide and deduced amino acid sequences were highly identical to those of other species. Adiponectin mRNA was detected in adipose tissues, but not in other tissues, of dogs. When 22 adult beagles were given a high-energy diet for 14 weeks, they became obese, showing heavier body weights, higher plasma leptin concentrations, but lower plasma adiponectin concentrations. The adiponectin concentrations of plasma samples collected from 71 dogs visiting veterinary practices were negatively correlated to plasma leptin concentrations, being lower in obese than non-obese dogs. These results are compatible with those reported in other species, and suggest that adiponectin is an index of adiposity and a target molecule for studies on diseases associated with obesity in dogs.

  11. Enhancement of carbon-steel peel adhesion to rubber blend using atmospheric pressure plasma

    NASA Astrophysics Data System (ADS)

    Kršková, Jana; Skácelová, Dana; Kováčik, Dušan; Ráhel', Jozef; Pret'o, Jozef; Černák, Mirko

    2016-08-01

    The surface of carbon-steel plates was modified by non-equilibrium plasma of diffuse coplanar surface barrier discharge (DCSBD) in order to improve the adhesive properties to the NR (natural rubber) green rubber compound. The effect of different treatment times as well as different input power and frequency of supplied high voltage was investigated. The samples were characterized using contact angle and surface free energy measurement, measurement of adhesive properties, scanning electron microscopy (SEM) and atomic force microscopy (AFM). Surface chemical composition was studied by energy-dispersive X-ray spectroscopy (EDX). Significant increase in wettability was observed even after 2 s of plasma exposure. The surface modification was confirmed also by peel test, where the best results were obtained for 6 s of plasma treatment. In addition the ageing effect was studied to investigate the durability of modification, which is crucial for the industrial applications. Contribution to the topical issue "6th Central European Symposium on Plasma Chemistry (CESPC-6)", edited by Nicolas Gherardi, Ester Marotta and Cristina Paradisi

  12. The measurement of acetanilide in plasma by spectrophotometric and selected ion monitoring methods.

    PubMed

    Baty, J D; Playfer, J; Evans, D A; Lamb, J

    1977-08-01

    Plasma samples from volunteers who had received an oral dose of acetanilide have been analysed by gas chromatography mass spectrometry and ultraviolet absorption techniques. The gas chromatography mass spectrometry method involved extraction of the plasma and analysis of the acetanilide using selected ion monitoring with a deuterated internal standard. In the ultraviolet method the plasma was hydrolysed with acid to convert the acetanilide to aniline, and this compound was diazotized and coupled with N-1-naphthylethylene-diamine. The absorbance of the resulting complex was read at 550 nm. Acetanilide levels in plasma determined by the selected ion monitoring method were significantly lower than those measured by spectrophotometry. Pharmacokinetic data calculated from the results obtained using these two assays are very different and illustrate the need for an accurate and specific method of analysis. The major metabolites of acetanilide are shown not to interfere with these assays and the results suggest the possible presence of a new metabolite of acetanilide.

  13. Ivermectin disposition kinetics after subcutaneous and intramuscular administration of an oil-based formulation to cattle.

    PubMed

    Lifschitz, A; Virkel, G; Pis, A; Imperiale, F; Sanchez, S; Alvarez, L; Kujanek, R; Lanusse, C

    1999-10-01

    Slight differences in formulation may change the plasma kinetics and ecto-endoparasiticide activity of endectocide compounds. This work reports on the disposition kinetics and plasma availability of ivermectin (IVM) after subcutaneous (SC) and intramuscular (IM) administration as an oil-based formulation to cattle. Parasite-free Aberdeen Angus calves (n = 24; 240-280 kg) were divided into three groups (n = 8) and treated (200 microg/kg) with either an IVM oil-based pharmaceutical preparation (IVM-TEST formulation) (Bayer Argentina S.A.) given by subcutaneous (Group A) and intramuscular (Group B) injections or the IVM-CONTROL (non-aqueous formulation) (Ivomec, MSD Agvet) subcutaneously administered (Group C). Blood samples were taken over 35 days post-treatment and the recovered plasma was extracted and analyzed by HPLC using fluorescence detection. IVM was detected in plasma between 12 h and 35 days post-administration of IVM-TEST (SC and IM injections) and IVM-CONTROL formulations. Prolonged IVM absorption half-life (p < 0.05) and delayed peak plasma concentration (p < 0.001) were obtained following the SC administration of the IVM-TEST compared to the IVM-CONTROL formulation. No differences in total plasma availability were observed among treatments. However, the plasma residence time and elimination half-life of IVM were significantly longer after injection of the IVM-TEST formulation. IVM plasma concentrations were above 0.5 ng/ml for 20.6 (CONTROL) and 27.5 days (IVM-TEST SC), respectively (p < 0.05). The modified kinetic behaviour of IVM obtained after the administration of the novel oil-based formulation examined in this trial, compared to the standard preparation, may positively impact on its strategic use in cattle.

  14. Effect of N-acetylcysteine on the accuracy of the prothrombin time assay of plasma coagulation factor II+VII+X activity in subjects infused with the drug. Influence of time and temperature.

    PubMed

    Thorsen, Sixtus; Teisner, Ane; Jensen, Søren Astrup; Philips, Malou; Dalhoff, Kim; Bendtsen, Flemming

    2009-01-01

    The prothrombin time (PT) assay of factor II+VII+X activity is an important predictor of liver damage in paracetamol poisoned patients. It complicates interpretation of results that the antidote, acetylcysteine (NAC) depresses this activity. The aim was to investigate if NAC influences the accuracy of the plasma PT assay. The accuracy of Nycotest PT was studied using plasma added NAC in vitro and plasma from subjects infused with NAC. The latter results were compared with those obtained by analysis of PT by CoaguChek S. Therapeutic NAC concentrations added to plasma in vitro decreased factor II+VII+X activity at 37 degrees C in a time-dependent manner. This effect was quenched at temperatures <24 degrees C. Activity lost at 37 degrees C could partly be recovered by subsequent incubation at 5 or 20 degrees C. Incubation at 37 degrees C prior to assay led to a significant additional depression of factor II+VII+X activity in plasma from subjects infused with NAC during the first 3h of infusion indicating that it contained reactive NAC. The risk that this NAC interfered with the accuracy of the PT assay was considered minimal with samples stored below 24 degrees C. This was supported by similarity of results obtained by analysis of appropriately stored plasma and simultaneously drawn blood by CoaguChek S. Residual reactive NAC does not interfere with the accuracy of the PT assay of plasma stored below 24 degrees C, but NAC-induced loss in activity at 37 degrees C may be partly recovered during subsequent storage below 24 degrees C.

  15. Influence of the pulsed plasma treatment on the corrosion resistance of the low-alloy steel plated by Ni-based alloy

    NASA Astrophysics Data System (ADS)

    Dzhumaev, P.; Yakushin, V.; Kalin, B.; Polsky, V.; Yurlova, M.

    2016-04-01

    This paper presents investigation results of the influence of high temperature pulsed plasma flows (HTPPF) treatment on the corrosion resistance of low-alloy steel 0.2C-Cr-Mn- Ni-Mo cladded by the rapidly quenched nickel-based alloy. A technique that allows obtaining a defect-free clad layer with a good adhesion to the substrate was developed. It is shown that the preliminary treatment of steel samples by nitrogen plasma flows significantly increases their corrosion resistance in the conditions of intergranular corrosion test in a water solution of sulfuric acid. A change of the corrosion mechanism of the clad layer from intergranular to uniform corrosion was observed as a result of sub-microcrystalline structure formation and homogeneous distribution of alloying elements in the plasma treated surface layer thus leading to the significant increase of the corrosion resistance.

  16. Detection of Peptide-based nanoparticles in blood plasma by ELISA.

    PubMed

    Bode, Gerard H; Pickl, Karin E; Sanchez-Purrà, Maria; Albaiges, Berta; Borrós, Salvador; Pötgens, Andy J G; Schmitz, Christoph; Sinner, Frank M; Losen, Mario; Steinbusch, Harry W M; Frank, Hans-Georg; Martinez-Martinez, Pilar

    2015-01-01

    The aim of the current study was to develop a method to detect peptide-linked nanoparticles in blood plasma. A convenient enzyme linked immunosorbent assay (ELISA) was developed for the detection of peptides functionalized with biotin and fluorescein groups. As a proof of principle, polymerized pentafluorophenyl methacrylate nanoparticles linked to biotin-carboxyfluorescein labeled peptides were intravenously injected in Wistar rats. Serial blood plasma samples were analyzed by ELISA and by liquid chromatography mass spectrometry (LC/MS) technology. The ELISA based method for the detection of FITC labeled peptides had a detection limit of 1 ng/mL. We were able to accurately measure peptides bound to pentafluorophenyl methacrylate nanoparticles in blood plasma of rats, and similar results were obtained by LC/MS. We detected FITC-labeled peptides on pentafluorophenyl methacrylate nanoparticles after injection in vivo. This method can be extended to detect nanoparticles with different chemical compositions.

  17. Detection of Peptide-Based Nanoparticles in Blood Plasma by ELISA

    PubMed Central

    Bode, Gerard H.; Pickl, Karin E.; Sanchez-Purrà, Maria; Albaiges, Berta; Borrós, Salvador; Pötgens, Andy J. G.; Schmitz, Christoph; Sinner, Frank M.; Losen, Mario; Steinbusch, Harry W. M.; Frank, Hans-Georg; Martinez-Martinez, Pilar

    2015-01-01

    Aims The aim of the current study was to develop a method to detect peptide-linked nanoparticles in blood plasma. Materials & Methods A convenient enzyme linked immunosorbent assay (ELISA) was developed for the detection of peptides functionalized with biotin and fluorescein groups. As a proof of principle, polymerized pentafluorophenyl methacrylate nanoparticles linked to biotin-carboxyfluorescein labeled peptides were intravenously injected in Wistar rats. Serial blood plasma samples were analyzed by ELISA and by liquid chromatography mass spectrometry (LC/MS) technology. Results The ELISA based method for the detection of FITC labeled peptides had a detection limit of 1 ng/mL. We were able to accurately measure peptides bound to pentafluorophenyl methacrylate nanoparticles in blood plasma of rats, and similar results were obtained by LC/MS. Conclusions We detected FITC-labeled peptides on pentafluorophenyl methacrylate nanoparticles after injection in vivo. This method can be extended to detect nanoparticles with different chemical compositions. PMID:25996618

  18. Dietary and hormonal interrelationships among vegetarian Seventh-Day Adventists and nonvegetarian men.

    PubMed

    Howie, B J; Shultz, T D

    1985-07-01

    The relationship between dietary nutrients and plasma testosterone, 5 alpha-dihydrotestosterone, estradiol-17 beta, luteinizing hormone, and prolactin levels was investigated in 12 Seventh-Day Adventist (SDA) vegetarian (SV), 10 SDA nonvegetarian (SNV), and 8 non-SDA nonvegetarian (NV) men. Fasting blood samples and 3-day dietary intake information were obtained from each subject. The SV subjects consumed significantly more crude and dietary fiber than the SNV and NV subjects, respectively. Plasma levels of testosterone and estradiol-17 beta were significantly lower in the SV than in the omnivores. Additionally, the plasma levels of testosterone and estradiol-17 beta of the combined groups (SV, SNV, and NV) revealed a significant negative relationship with their crude and dietary fiber intakes. These subjects hormonal milieu was related to specific dietary constituents, possibly leading to a decreased plasma concentration of androgen and estrogen in vegetarians. Implications include the possible modification of prostate cancer risk through dietary intervention.

  19. Simulation of SiO2 etching in an inductively coupled CF4 plasma

    NASA Astrophysics Data System (ADS)

    Xu, Qing; Li, Yu-Xing; Li, Xiao-Ning; Wang, Jia-Bin; Yang, Fan; Yang, Yi; Ren, Tian-Ling

    2017-02-01

    Plasma etching technology is an indispensable processing method in the manufacturing process of semiconductor devices. Because of the high fluorine/carbon ratio of CF4, the CF4 gas is often used for etching SiO2. A commercial software ESI-CFD is used to simulate the process of plasma etching with an inductively coupled plasma model. For the simulation part, CFD-ACE is used to simulate the chamber, and CFD-TOPO is used to simulate the surface of the sample. The effects of chamber pressure, bias voltage and ICP power on the reactant particles were investigated, and the etching profiles of SiO2 were obtained. Simulation can be used to predict the effects of reaction conditions on the density, energy and angular distributions of reactant particles, which can play a good role in guiding the etching process.

  20. Complex polarimetric and spectral techniques in diagnostics of blood plasma of patients with ovarian cancer as a preliminary stage molecular genetic screening

    NASA Astrophysics Data System (ADS)

    Grzegorzewski, B.; Peresunko, O. P.; Yermolenko, S. B.

    2018-01-01

    This work is devoted to the substantiation and selection of patients with ovarian cancer (OC) for the purpose of conducting expensive molecular genetic studies on genotyping. As diagnostic methods have been used ultraviolet spectrometry samples of blood plasma in the liquid state, infrared spectroscopy middle range (2,5 - 25 microns) dry residue of plasma polarization and laser diagnostic technique of thin histological sections of biological tissues. Obtained results showed that the use of spectrophotometry in the range of 1000-3000 cm-1 allowed to establish quantitative parameters of the plasma absorption rate of blood of patients in the third group in different ranges, which would allow in the future to conduct an express analysis of the patient's condition (procedure screening) for further molecular-genetic typing on BRCA I and II.

  1. Enhanced high-performance liquid chromatography method for the determination of retinoic acid in plasma. Development, optimization and validation.

    PubMed

    Teglia, Carla M; Gil García, María D; Galera, María Martínez; Goicoechea, Héctor C

    2014-08-01

    When determining endogenous compounds in biological samples, the lack of blank or analyte-free matrix samples involves the use of alternative strategies for calibration and quantitation. This article deals with the development, optimization and validation of a high performance liquid chromatography method for the determination of retinoic acid in plasma, obtaining at the same time information about its isomers, taking into account the basal concentration of these endobiotica. An experimental design was used for the optimization of three variables: mobile phase composition, flow rate and column temperature through a central composite design. Four responses were selected for optimization purposes (area under the peaks, quantity of peaks, analysis time and resolution between the first principal peak and the following one). The optimum conditions resulted in a mobile phase consisting of methanol 83.4% (v/v), acetonitrile 0.6% (v/v) and acid aqueous solution 16.0% (v/v); flow rate of 0.68 mL min(-1) and an column temperature of 37.10 °C. Detection was performed at 350 nm by a diode array detector. The method was validated following a holistic approach that included not only the classical parameters related to method performance but also the robustness and the expected proportion of acceptable results lying inside predefined acceptability intervals, i.e., the uncertainty of measurements. The method validation results indicated a high selectivity and good precision characteristics that were studied at four concentration levels, with RSD less than 5.0% for retinoic acid (less than 7.5% for the LOQ concentration level), in intra and inter-assay precision studies. Linearity was proved for a range from 0.00489 to 15.109 ng mL(-1) of retinoic acid and the recovery, which was studied at four different fortification levels in phuman plasma samples, varied from 99.5% to 106.5% for retinoic acid. The applicability of the method was demonstrated by determining retinoic acid and obtaining information about its isomers in human and frog plasma samples from different origins. Copyright © 2014 Elsevier B.V. All rights reserved.

  2. Data on the influence of cold isostatic pre-compaction on mechanical properties of polycrystalline nickel sintered using Spark Plasma Sintering.

    PubMed

    Dutel, Guy-Daniel; Langlois, Patrick; Tingaud, David; Vrel, Dominique; Dirras, Guy

    2017-04-01

    Data regarding bulk polycrystalline nickel samples obtained by powder metallurgy using Spark Plasma Sintering (SPS) are presented, with a special emphasis on the influence of a cold isostatic pre-compaction on the resulting morphologies and subsequent mechanical properties. Three types of initial powders are used, nanometric powders, micrometric powders and a mixture of the formers. For each type of powder, the SPS cycle has been optimized for the powders without pre-compaction and the same cycle has been used to also sinter pre-compacted powders.

  3. A novel strategy using MASCOT Distiller for analysis of cleavable isotope-coded affinity tag data to quantify protein changes in plasma.

    PubMed

    Leung, Kit-Yi; Lescuyer, Pierre; Campbell, James; Byers, Helen L; Allard, Laure; Sanchez, Jean-Charles; Ward, Malcolm A

    2005-08-01

    A novel strategy consisting of cleavable Isotope-Coded Affinity Tag (cICAT) combined with MASCOT Distiller was evaluated as a tool for the quantification of proteins in "abnormal" patient plasma, prepared by pooling samples from patients with acute stroke. Quantification of all light and heavy cICAT-labelled peptide ion pairs was obtained using MASCOT Distiller combined with a proprietary software. Peptides displaying differences were selected for identification by MS. These preliminary results show the promise of our approach to identify potential biomarkers.

  4. Structure-property and composition-property relationships for poly(ethylene terephthalate) surfaces modified by helium plasma-based ion implantation

    NASA Astrophysics Data System (ADS)

    Tóth, A.; Veres, M.; Kereszturi, K.; Mohai, M.; Bertóti, I.; Szépvölgyi, J.

    2011-10-01

    The surfaces of untreated and helium plasma-based ion implantation (He PBII) treated poly(ethylene terephthalate) (PET) samples were characterised by reflectance colorimetry, contact angle studies and measurements of surface electrical resistance. The results were related to the structural and compositional data obtained by the authors earlier on parallel samples by XPS and Raman spectroscopy. Inverse correlations between lightness and ID/ IG ratio and between chroma and ID/ IG ratio were obtained, suggesting that the PBII-treated PET samples darken and their colourfulness decreases with the increase of the portion of aromatic sp 2 carbon rings in the chemical structure of the modified layer. Direct correlation between water contact angle and the ID/ IG ratio and inverse correlations between surface energy and ID/ IG ratio and between dispersive component of surface energy and ID/ IG ratio were found, reflecting that surface wettability, surface energy and its dispersive component decrease with the formation of surface structure, characterised again by enhanced portion of aromatic sp 2 carbon rings. The surface electrical resistance decreased with the increase of the surface C-content determined by XPS and also with the increase of the surface concentration of conjugated double bonds, reflected by the increase of the π → π* shake-up satellite of the C 1s peak.

  5. Conversion of α-linolenic acid to long-chain omega-3 fatty acid derivatives and alterations of HDL density subfractions and plasma lipids with dietary polyunsaturated fatty acids in Monk parrots (Myiopsitta monachus).

    PubMed

    Petzinger, C; Larner, C; Heatley, J J; Bailey, C A; MacFarlane, R D; Bauer, J E

    2014-04-01

    The effect of α-linolenic acid from a flaxseed (FLX)-enriched diet on plasma lipid and fatty acid metabolism and possible atherosclerosis risk factors was studied in Monk parrots (Myiopsitta monachus). Twenty-four Monk parrots were randomly assigned to diets containing either 10% ground SUNs or 10% ground FLXs. Feed intake was calculated daily. Blood samples, body condition scores and body weights were obtained at -5 weeks, day 0, 7, 14, 28, 42 and 70. Plasma samples were analysed for total cholesterol, free cholesterol, triacylglycerols and lipoproteins. Phospholipid subfraction fatty acid profiles were determined. By day 70, the FLX group had significantly higher plasma phospholipid fatty acids including 18:3n-3 (α-linolenic acid), 20:5n-3 (eicosapentaenoic acid) and 22:6n-3 (docosahexaenoic acid). The sunflower group had significantly higher plasma phospholipid levels of 20:4n-6 (arachidonic acid). By day 70, the high-density lipoprotein (HDL) peak shifted resulting in significantly different HDL peak densities between the two experimental groups (1.097 g/ml FLX group and 1.095 g/ml SUN group, p = 0.028). The plasma fatty acid results indicate that Monk parrots can readily convert α-linolenic acid to the long-chain omega-3 derivatives including docosahexaenoic acid and reduce 20:4n-6 accumulation in plasma phospholipids. The reason for a shift in the HDL peak density is unknown at this time. Journal of Animal Physiology and Animal Nutrition © 2013 Blackwell Verlag GmbH.

  6. Red blood cells for transfusion in patients with sepsis: respective roles of unit age and exposure to recipient plasma.

    PubMed

    Chadebech, Philippe; Bodivit, Gwellaouen; Razazi, Keyvan; de Vassoigne, Christophe; Pellé, Laurence; Burin-des-Roziers, Nicolas; Bocquet, Thibault; Bierling, Philippe; Djoudi, Rachid; Mekontso-Dessap, Armand; Pirenne, France

    2017-08-01

    Red blood cell (RBC) storage in blood banks is not exempt from cellular injury. Alterations not observed on RBCs freshly isolated from units can rapidly appear in circulation. The transfusion of old blood units, even if this is a controversial issue, could therefore have adverse effects on the recipient. We wanted to determine the respective effects of storage duration and recipient plasma on RBCs for transfusion into patients with severe sepsis. Eleven stored RBC units were sampled at various time points, approximately Days 3 to 8 (referred to as fresh RBCs) and Days 38 to 42 (old RBCs) and tested in coincubation experiments with plasma obtained from 13 patients with severe sepsis and 17 healthy donors as controls. RBCs were tested after 24 or 48 hours at 37°C for the detection of senescence markers (phosphatidylserine exposure, calcium influx, and reactive oxygen species detection and decrease in size) with or without exposure to plasma. We confirmed that a 42-day refrigerated storage of RBCs alone (without any incubation in plasma) had no significant effect on RBCs and no senescence marker detected. By contrast, ex vivo exposure to plasma samples altered both fresh and old RBCs, with a much larger effect for old RBCs, regardless of the plasma used (sepsis vs. control). We show that the main factor affecting the senescence of RBCs for transfusion into patients with severe sepsis is the age of the stored units rather than the clinical status of the recipient. © 2017 AABB.

  7. Enantioselective analysis of ibuprofen in human plasma by anionic cyclodextrin-modified electrokinetic chromatography.

    PubMed

    Jabor, Valquíria A P; Lanchote, Vera L; Bonato, Pierina S

    2002-09-01

    This paper reports the development of a rapid method for the enantioselective analysis of the nonsteroidal anti-inflammatory drug ibuprofen in human plasma by capillary electrophoresis employing the anionic cyclodextrin-modified electrokinetic chromatography mode. Sample cleanup was carried out by acidification with HCl followed by liquid-liquid extraction with hexane:isopropanol (99:1 v/v). The complete enantioselective analysis was performed within 10 min, using 100 mmol L(-1) phosphoric acid/triethanolamine buffer, pH 2.6, containing 2.0% w/v sulfated beta-cyclodextrin as chiral selector; fenoprofen, another nonsteroidal anti-inflammatory drug, was used as internal standard. The calibration curves were linear over the concentration range of 0.25-125.0 microg mL(-1) for each enantiomer of ibuprofen. The mean recoveries for ibuprofen enantiomers were up to 85%. The enantiomers studied could be quantified at three different concentrations (0.5, 5.0 and 50.0 microg mL(-1)) with a coefficient of variation and relative error not higher than 15%. The quantitation limit was 0.2 microg mL(-1) for (+)-(S)- and (-)-(R)-ibuprofen using 1 mL of human plasma. The plasma endogenous compounds and other drugs did not interfere with the present assay. The analysis of real plasma samples obtained from a healthy volunteer after administration of 600 mg of racemic ibuprofen showed a maximum plasma level of 29.6 and 39.9 microg mL(-1) of (-)-(R)- and (+)-(S)-ibuprofen, respectively, and the area under plasma concentration-time curve AUC(0-infinity) (+)-(S)/AUC(0-infinity) (-)-(R) ratio was 1.87.

  8. Energy metabolism in mobile, wild-sampled sharks inferred by plasma lipids

    PubMed Central

    Skubel, Rachel A.; Pethybridge, Heidi R.; Hammerschlag, Neil

    2017-01-01

    Abstract Evaluating how predators metabolize energy is increasingly useful for conservation physiology, as it can provide information on their current nutritional condition. However, obtaining metabolic information from mobile marine predators is inherently challenging owing to their relative rarity, cryptic nature and often wide-ranging underwater movements. Here, we investigate aspects of energy metabolism in four free-ranging shark species (n = 281; blacktip, bull, nurse, and tiger) by measuring three metabolic parameters [plasma triglycerides (TAG), free fatty acids (FFA) and cholesterol (CHOL)] via non-lethal biopsy sampling. Plasma TAG, FFA and total CHOL concentrations (in millimoles per litre) varied inter-specifically and with season, year, and shark length varied within a species. The TAG were highest in the plasma of less active species (nurse and tiger sharks), whereas FFA were highest among species with relatively high energetic demands (blacktip and bull sharks), and CHOL concentrations were highest in bull sharks. Although temporal patterns in all metabolites were varied among species, there appeared to be peaks in the spring and summer, with ratios of TAG/CHOL (a proxy for condition) in all species displaying a notable peak in summer. These results provide baseline information of energy metabolism in large sharks and are an important step in understanding how the metabolic parameters can be assessed through non-lethal sampling in the future. In particular, this study emphasizes the importance of accounting for intra-specific and temporal variability in sampling designs seeking to monitor the nutritional condition and metabolic responses of shark populations. PMID:28852506

  9. LC-MS/MS analysis of metformin, saxagliptin and 5-hydroxy saxagliptin in human plasma and its pharmacokinetic study with a fixed-dose formulation in healthy Indian subjects.

    PubMed

    Shah, Priyanka A; Shah, Jaivik V; Sanyal, Mallika; Shrivastav, Pranav S

    2017-03-01

    A specific and rapid liquid chromatography-tandem mass spectrometry method is proposed for the simultaneous determination of metformin (MET), saxagliptin (SAXA) and its active metabolite, 5-hydroxy saxagliptin (5-OH SAXA) in human plasma. Sample preparation was accomplished from 50 μL plasma sample by solid-phase extraction using sodium dodecyl sulfate as an ion-pair reagent. Reversed-phase chromatographic resolution of analytes was possible within 3.5 min on ACE 5CN (150 × 4.6 mm, 5 μm) column using acetonitrile and10.0 mm ammonium formate buffer, pH 5.0 (80:20, v/v) as the mobile phase. Triple quadrupole mass spectrometric detection was performed using electrospray ionization in the positive ionization mode. The calibration curves showed good linearity (r 2  ≥ 0.9992) over the established concentration range with limit of quantification of 1.50, 0.10 and 0.20 ng/mL for MET, SAXA and 5-OH SAXA respectively. The extraction recoveries obtained from spiked plasma samples were highly consistent for MET (75.12-77.84%), SAXA (85.90-87.84%) and 5-OH SAXA (80.32-82.69%) across quality controls. The validated method was successfully applied to a bioequivalence study with a fixed-dose formulation consisting of 5 mg SAXA and 500 mg MET in 18 healthy subjects. The reproducibility of the assay was demonstrated by reanalysis of 87 incurred samples. Copyright © 2016 John Wiley & Sons, Ltd.

  10. Development and validation of a sensitive LC-MS/MS method for the determination of fenoterol in human plasma and urine samples.

    PubMed

    Sanghvi, M; Ramamoorthy, A; Strait, J; Wainer, I W; Moaddel, R

    2013-08-15

    Due to the lack of sensitivity in current methods for the determination of fenoterol (Fen), a rapid LC-MS/MS method was developed for the determination of (R,R')-Fen and (R,R';S,S')-Fen in plasma and urine. The method was fully validated and was linear from 50pg/ml to 2000pg/ml for plasma and from 2.500ng/ml to 160ng/ml for urine with a lower limit of quantitation of 52.8pg/ml in plasma. The coefficient of variation was <15% for the high QC standards and <10% for the low QC standards in plasma and was <15% for the high and low QC standards in urine. The relative concentrations of (R,R')-Fen and (S,S')-Fen were determined using a chirobiotic T chiral stationary phase. The method was used to determine the concentration of (R,R')-Fen in plasma and urine samples obtained in an oral cross-over study of (R,R')-Fen and (R,R';S,S')-Fen formulations. The results demonstrated a potential pre-systemic enantioselective interaction in which the (S,S')-Fen reduces the sulfation of the active (R,R')-Fen. The data suggest that a non-racemic mixture of the Fen enantiomers may provide better bioavailability of the active (R,R')-Fen for use in the treatment of cardiovascular disease. Published by Elsevier B.V.

  11. Development of a label-free immunosensor system for detecting plasma cortisol levels in fish.

    PubMed

    Wu, Haiyun; Ohnuki, Hitoshi; Hibi, Kyoko; Ren, Huifeng; Endo, Hideaki

    2016-02-01

    Fishes display a wide variation in their physiological responses to stress, which is clearly evident in the plasma corticosteroid changes, chiefly cortisol levels in fish. In the present study, we describe a novel label-free immunosensor for detecting plasma cortisol levels. The method is based on immunologic reactions and amperometric measurement using cyclic voltammetry. For the immobilization of the antibody on the surface of sensing electrode, we used a self-assembled monolayer of thiol-containing compounds. Using this electrode, we detect the CV signal change caused by the generation of antigen-antibody complex. The immunosensor showed a response to cortisol levels, and the anodic peak value linearly decreased with a correlation coefficient of 0.990 in diluted plasma. The specificity of the label-free immunosensor system was investigated using other steroid hormones, such as 17α, 20β-dihydroxy-4-pregnen-3-one, progesterone, estriol, estradiol, and testosterone. The specific detection of cortisol was suggested by a minimal change from -0.32 to 0.51 μA in the anodic peak value of the other steroid hormones. The sensor system was used to determine the plasma cortisol levels in Nile tilapia (Oreochromis niloticus), and the results were compared with those of the same samples determined using the conventional method (ELISA). A good correlation was obtained between values determined using both methods (correlation coefficient 0.993). These findings suggest that the proposed label-free immunosensor could be useful for rapid and convenient analysis of cortisol levels in fish plasma samples.

  12. Evaluation of single-nucleotide polymorphisms as internal controls in prenatal diagnosis of fetal blood groups.

    PubMed

    Doescher, Andrea; Petershofen, Eduard K; Wagner, Franz F; Schunter, Markus; Müller, Thomas H

    2013-02-01

    Determination of fetal blood groups in maternal plasma samples critically depends on adequate amplification of fetal DNA. We evaluated the routine inclusion of 52 single-nucleotide polymorphisms (SNPs) as internal reference in our polymerase chain reaction (PCR) settings to obtain a positive internal control for fetal DNA. DNA from 223 plasma samples of pregnant women was screened for RHD Exons 3, 4, 5, and 7 in a multiplex PCR including 52 SNPs divided into four primer pools. Amplicons were analyzed by single-base extension and the GeneScan method in a genetic analyzer. Results of D screening were compared to standard RHD genotyping of amniotic fluid or real-time PCR of fetal DNA from maternal plasma. The vast majority of all samples (97.8%) demonstrated differences in maternal and fetal SNP patterns when tested with four primer pools. These differences were not observed in less than 2.2% of the samples most probably due to an extraction failure for adequate amounts of fetal DNA. Comparison of the fetal genotypes with independent results did not reveal a single false-negative case among samples (n = 42) with positive internal control and negative fetal RHD typing. Coamplification of 52 SNPs with RHD-specific sequences for fetal blood group determination introduces a valid positive control for the amplification of fetal DNA to avoid false-negative results. This new approach does not require a paternal blood sample. It may also be applicable to other assays for fetal genotyping in maternal blood samples. © 2012 American Association of Blood Banks.

  13. Formation of Nanocones on Highly Oriented Pyrolytic Graphite by Oxygen Plasma

    PubMed Central

    Vesel, Alenka; Eleršič, Kristina; Modic, Martina; Junkar, Ita; Mozetič, Miran

    2014-01-01

    Improvement in hemocompatibility of highly oriented pyrolytic graphite (HOPG) by formation of nanostructured surface by oxygen plasma treatment is reported. We have showed that by appropriate fine tuning of plasma and discharge parameters we are able to create nanostructured surface which is densely covered with nanocones. The size of the nanocones strongly depended on treatment time. The optimal results in terms of material hemocompatibility were obtained after treatment with oxygen plasma for 15 s, when both the nanotopography and wettability were the most favorable, since marked reduction in adhesion and activation of platelets was observed on this surface. At prolonged treatment times, the rich surface topography was lost and thus also its antithrombogenic properties. Chemical composition of the surface was always more or less the same, regardless of its morphology and height of the nanocones. Namely, on all plasma treated samples, only a few atomic percent of oxygen was found, meaning that plasma caused mostly etching, leading to changes in the surface morphology. This indicates that the main preventing mechanism against platelets adhesion was the right surface morphology. PMID:28788553

  14. Characterization of Mullite-Zirconia Composite Processed by Non-Transferred and Transferred Arc Plasma

    NASA Astrophysics Data System (ADS)

    Yugeswaran, S.; Selvarajan, V.; Lusvarghi, L.; I. Y. Tok, A.; D. Siva Rama, Krishna

    2009-04-01

    The arc plasma melting technique is a simple method to synthesize high temperature reaction composites. In this study, mullite-zirconia composite was synthesized by transferred and non-transferred arc plasma melting, and the results were compared. A mixture of alumina and zircon powders with a mole ratio of 3: 2 were ball milled for four hours and melted for two minutes in the transferred and non-transferred mode of plasma arcs. Argon and air were used as plasma forming gases. The phase and microstructural formation of melted samples were investigated by X-ray diffraction (XRD) and scanning electron microscope (SEM). The microstructure of the composites was found to be affected by the mode of melting. In transferred arc melting, zirconia flowers with uniform lines along with mullite whiskers were obtained. In the case of non-transferred arc plasma melting, mullite whiskers along with star shape zirconia were formed. Differential thermal analysis (DTA) of the synthesized mullite-zirconia composites provided a deeper understanding of the mechanisms of mullite formation during the two different processes.

  15. Plasma endotoxin activity in Eastern grey kangaroos (Macropus giganteus) with lumpy jaw disease

    PubMed Central

    SOTOHIRA, Yukari; SUZUKI, Kazuyuki; OTSUKA, Marina; TSUCHIYA, Masakazu; SHIMAMORI, Toshio; NISHI, Yasunobu; TSUKANO, Kenji; ASAKAWA, Mitsuhiko

    2017-01-01

    Progressive pyogranulomatous osteomyelitis involving the mandible or maxilla of captive macropods, referred to as “Lumpy jaw disease (LJD)”, is one of the most significant causes of illness and death in captive macropods. The aim of the present study was to evaluate the relationship between the severity of LJD and plasma endotoxin activity in kangaroos. Plasma samples obtained from moderate (n=24) and severe LJD (n=12), and healthy kangaroos (n=46), were diluted 1:20 in endotoxin-free water and heated to 80°C for 10 min. Plasma endotoxin activity was measured using the Limulus amebocyte lysate (LAL)-kinetic turbidimetric (KT) assay. Plasma endotoxin activity was higher in kangaroos with severe LJD (0.199 ± 0.157 EU/ml) than in those with moderate LJD (0.051 ± 0.012 EU/ml, P<0.001) and healthy controls (0.057 ± 0.028 EU/ml, P<0.001). Our results suggest that the severity of LJD in captive macropods may be related to the plasma endotoxin activity. PMID:28484148

  16. Sequential chemical extraction for a phosphogypsum environmental impact evaluation

    NASA Astrophysics Data System (ADS)

    Gennari, R. F.; Garcia, I.; Medina, N. H.; Silveira, M. A. G.

    2013-05-01

    Phosphogypsum (PG) is gypsum generated during phosphoric acid production. PG is stocked in large stacks or accumulated in lakes; it contains heavy metals and naturally occurring radioactive elements. The metal contamination may affect the functionality, sustainability and biodiversity of ecosystems. In this work, PG samples were analyzed by Plasma Spectrometry. Total metal content and in the extractable fraction of chemical elements were determined. For K, Ni, Zn, Cr, Cd, Ba, Pb and U, the results obtained are lower than those obtained in a Idaho plant are including and also lower than those found in the soil, indicating this PG sample analyzed probably will not cause any additional metal neither natural radiation contamination.

  17. Protein catabolism and high lipid metabolism associated with long-distance exercise are revealed by plasma NMR metabolomics in endurance horses.

    PubMed

    Le Moyec, Laurence; Robert, Céline; Triba, Mohamed N; Billat, Véronique L; Mata, Xavier; Schibler, Laurent; Barrey, Eric

    2014-01-01

    During long distance endurance races, horses undergo high physiological and metabolic stresses. The adaptation processes involve the modulation of the energetic pathways in order to meet the energy demand. The aims were to evaluate the effects of long endurance exercise on the plasma metabolomic profiles and to investigate the relationships with the individual horse performances. The metabolomic profiles of the horses were analyzed using the non-dedicated methodology, NMR spectroscopy and statistical multivariate analysis. The advantage of this method is to investigate several metabolomic pathways at the same time in a single sample. The plasmas were obtained before exercise (BE) and post exercise (PE) from 69 horses competing in three endurance races at national level (130-160 km). Biochemical assays were also performed on the samples taken at PE. The proton NMR spectra were compared using the supervised orthogonal projection on latent structure method according to several factors. Among these factors, the race location was not significant whereas the effect of the race exercise (sample BE vs PE of same horse) was highly discriminating. This result was confirmed by the projection of unpaired samples (only BE or PE sample of different horses). The metabolomic profiles proved that protein, energetic and lipid metabolisms as well as glycoproteins content are highly affected by the long endurance exercise. The BE samples from finisher horses could be discriminated according to the racing speed based on their metabolomic lipid content. The PE samples could be discriminated according to the horse ranking position at the end of the race with lactate as unique correlated metabolite. As a conclusion, the metabolomic profiles of plasmas taken before and after the race provided a better understanding of the high energy demand and protein catabolism pathway that could expose the horses to metabolic disorders.

  18. Diagnosing the plasma nonuniformity in an iron opacity experiment by spatially resolved Al 1s-2p absorption spectroscopy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang Xiaoding; Research Center of Laser Fusion, P. O. Box 919-986, Mianyang 621900; Zhang Jiyan

    Generating a well-characterized hot-dense sample is of great importance to high quality opacity measurements. In this paper, we report on an experimental investigation of the plasma nonuniformity in a radiatively heated iron opacity sample by spatially resolved Al 1s-2p absorption spectroscopy. The iron sample was tamped by plastic at both sides and was heated by thermal x-ray radiation generated in a gold Hohlraum, and an Al layer attached to it was used as a tracer for temperature diagnosis. Spatially resolved 1s-2p transition absorption spectra of the Al tracer were measured by the technique of point-projection-spectroscopy, and temperatures in the samplemore » were obtained by comparing the measured spectra with detailed-term-accounting model calculations, with the density of the sample deduced using a combination of side-on radiography and radiative hydrodynamic simulation. The results showed the existence of axial temperature nonuniformity in the sample, and these temperature variations have been used to explain the shift of iron 2p-3d transition absorption feature along the axial direction of the Hohlraum used to heat the sample successfully.« less

  19. Longitudinal change in plasma total homocysteine during pregnancy and postpartum in Brazilian women and its relation with folate status and other factors.

    PubMed

    Glorimar, R; Pereira, S E A; Trugo, N M F

    2004-03-01

    Fasting plasma total homocysteine (tHcy) concentration was determined in a cohort of pregnant Brazilian women (n = 46) supplemented with folic acid from the second trimester of pregnancy. Blood samples were obtained in the first and third trimesters from all women, and 30-40 days postpartum from seventeen women. Plasma tHcy decreased during pregnancy from 10.3 to 8.7 micromol/L, and was 11.6 micromol/L in the postpartum. Plasma and erythrocyte folate increased, consistent with use of the folate supplement, but decreased slightly in the postpartum, whereas the opposite occurred for plasma vitamin B12. tHcy was inversely correlated with plasma and erythrocyte folate in the third trimester (r = -0.585 and -0.460, respectively). This relationship occurred despite the fact that all women had attained what could be considered adequate levels of folate indices. Furthermore, the change (third trimester minus first trimester levels) of tHcy was inversely correlated (p < 0.01) with the changes in plasma (r = -0.573) and erythrocyte folate (r = -0.525). tHcy had no correlation in any of the periods tested with plasma vitamin B12, plasma albumin, hematocrit, hemoglobin, iron indices, dietary intakes of folate, vitamins B12 and B6, and levels of folate supplement.

  20. Polarized Raman spectroscopic characterization of normal and oral cancer blood plasma

    NASA Astrophysics Data System (ADS)

    Pachaiappan, Rekha; Prakasarao, Aruna; Singaravelu, Ganesan

    2017-02-01

    In India oral cancer ranks the top due to the habitual usage of tobacco in its various forms and remains the major burden. Hence priority is given for early diagnosis as it is the better solution for cure or to improve the survival rate. For the past three decades, optical spectroscopic techniques have shown its capacity in the discrimination of normal and malignant samples. Many research works have conventional Raman in the effective detection of cancer using the variations in bond vibrations of the molecules. However in addition polarized Raman provides the orientation and symmetry of biomolecules. If so can polarized Raman be the better choice than the conventional Raman in the detection of cancer? The present study aimed to found the answer for the above query. The conventional and polarized Raman spectra were acquired for the same set of blood plasma samples of normal subjects and oral malignant (OSCC) patients. Thus, obtained Raman spectral data were compared using linear discriminant analysis coupled with artificial neural network (LDA-ANN). The depolarization ratio of biomolecules such as antioxidant, amino acid, protein and nucleic acid bases present in blood plasma was proven to be the best attributes in the categorization of the groups. The polarized Raman results were promising in discriminating oral cancer blood plasma from that of normal blood plasma with improved efficiency. The results will be discussed in detail.

  1. IL8 and IL16 levels indicate serum and plasma quality.

    PubMed

    Kofanova, Olga; Henry, Estelle; Quesada, Rocio Aguilar; Bulla, Alexandre; Linares, Hector Navarro; Lescuyer, Pierre; Shea, Kathi; Stone, Mars; Tybring, Gunnel; Bellora, Camille; Betsou, Fay

    2018-02-09

    Longer pre-centrifugation times alter the quality of serum and plasma samples. Markers for such delays in sample processing and hence for the sample quality, have been identified. Twenty cytokines in serum, EDTA plasma and citrate plasma samples were screened for changes in concentration induced by extended blood pre-centrifugation delays at room temperature. The two cytokines that showed the largest changes were further validated for their "diagnostic performance" in identifying serum or plasma samples with extended pre-centrifugation times. In this study, using R&D Systems ELISA kits, EDTA plasma samples and serum samples with a pre-centrifugation delay longer than 24 h had an IL16 concentration higher than 313 pg/mL, and an IL8 concentration higher than 125 pg/mL, respectively. EDTA plasma samples with a pre-centrifugation delay longer than 48 h had an IL16 concentration higher than 897 pg/mL, citrate plasma samples had an IL8 concentration higher than 21.5 pg/mL and serum samples had an IL8 concentration higher than 528 pg/mL. These robust and accurate tools, based on simple and commercially available ELISA assays can greatly facilitate qualification of serum and plasma legacy collections with undocumented pre-analytics.

  2. Isolation of herpesvirus and Newcastle disease virus from White Storks (Ciconia ciconia) maintained at four rehabilitation centres in northern Germany during 1983 to 2001 and failure to detect antibodies against avian influenza A viruses of subtypes H5 and H7 in these birds.

    PubMed

    Kaleta, Erhard F; Kummerfeld, Norbert

    2012-01-01

    Herpesvirus isolations from peripheral white blood cells of 253 White Storks (Ciconia ciconia) were obtained during a long-term study (1983 to 2001). The storks lived for a few months to 20 years at four rehabilitation centres. Isolates were obtained from 83 of 253 storks. This herpesvirus is indigenous for storks and unrelated to any other avian herpesvirus. Significantly more herpesvirus isolates were obtained during spring than in autumn samplings. The intervals between the first and last virus isolation ranged from 1 to 15 years. Herpesvirus isolates were simultaneously obtained from white blood cells and from pharyngeal swabs of four of 34 storks but not from cloacal swabs. Neutralizing antibodies to stork herpesvirus were detected in 178 of 191 examined blood plasma samples. Neutralizing antibodies against stork herpesvirus did not correlate with herpesvirus viraemia. The results further substantiate the persistence of herpesvirus in White Storks and underline the previously unrecorded long periods of virus and antibody presence. Virulent avian paramyxovirus type 1 (APMV-1; Newcastle disease virus) was isolated from white blood cells during 1992 and 1993 from four healthy migrating storks, and possessed virulence markers on the cleavage site of the H and F genes. These properties resemble the NE type of APMV-1. Haemagglutination inhibition antibodies against APMV-1 were detected in 16 of 191 blood plasma samples. Avian influenza A virus was not isolated and antibodies against subtypes H5 and H7 were not detected.

  3. Pre-analytical effects of blood sampling and handling in quantitative immunoassays for rheumatoid arthritis.

    PubMed

    Zhao, Xiaoyan; Qureshi, Ferhan; Eastman, P Scott; Manning, William C; Alexander, Claire; Robinson, William H; Hesterberg, Lyndal K

    2012-04-30

    Variability in pre-analytical blood sampling and handling can significantly impact results obtained in quantitative immunoassays. Understanding the impact of these variables is critical for accurate quantification and validation of biomarker measurements. Particularly, in the design and execution of large clinical trials, even small differences in sample processing and handling can have dramatic effects in analytical reliability, results interpretation, trial management and outcome. The effects of two common blood sampling methods (serum vs. plasma) and two widely-used serum handling methods (on the clot with ambient temperature shipping, "traditional", vs. centrifuged with cold chain shipping, "protocol") on protein and autoantibody concentrations were examined. Matched serum and plasma samples were collected from 32 rheumatoid arthritis (RA) patients representing a wide range of disease activity status. Additionally, a set of matched serum samples with two sample handling methods was collected. One tube was processed per manufacturer's instructions and shipped overnight on cold packs (protocol). The matched tube, without prior centrifugation, was simultaneously shipped overnight at ambient temperatures (traditional). Upon delivery, the traditional tube was centrifuged. All samples were subsequently aliquoted and frozen prior to analysis of protein and autoantibody biomarkers. Median correlation between paired serum and plasma across all autoantibody assays was 0.99 (0.98-1.00) with a median % difference of -3.3 (-7.5 to 6.0). In contrast, observed protein biomarker concentrations were significantly affected by sample types, with median correlation of 0.99 (0.33-1.00) and a median % difference of -10 (-55 to 23). When the two serum collection/handling methods were compared, the median correlation between paired samples for autoantibodies was 0.99 (0.91-1.00) with a median difference of 4%. In contrast, significant increases were observed in protein biomarker concentrations among certain biomarkers in samples processed with the 'traditional' method. Autoantibody quantification appears robust to both sample type (plasma vs. serum) and pre-analytical sample collection/handling methods (protocol vs. traditional). In contrast, for non-antibody protein biomarker concentrations, sample type had a significant impact; plasma samples generally exhibit decreased protein biomarker concentrations relative to serum. Similarly, sample handling significantly impacted the variability of protein biomarker concentrations. When biomarker concentrations are combined algorithmically into a single test score such as a multi-biomarker disease activity test for rheumatoid arthritis (MBDA), changes in protein biomarker concentrations may result in a bias of the score. These results illustrate the importance of characterizing pre-analytical methodology, sample type, sample processing and handling procedures for clinical testing in order to ensure test accuracy. Copyright © 2012 Elsevier B.V. All rights reserved.

  4. The effects of residual platelets in plasma on plasminogen activator inhibitor-1 and plasminogen activator inhibitor-1-related assays.

    PubMed

    Pieters, Marlien; Barnard, Sunelle A; Loots, Du Toit; Rijken, Dingeman C

    2017-01-01

    Due to controversial evidence in the literature pertaining to the activity of plasminogen activator inhibitor-1 in platelets, we examined the effects of residual platelets present in plasma (a potential pre-analytical variable) on various plasminogen activator inhibitor-1 and plasminogen activator inhibitor-1-related assays. Blood samples were collected from 151 individuals and centrifuged at 352 and 1500 g to obtain plasma with varying numbers of platelet. In a follow-up study, blood samples were collected from an additional 23 individuals, from whom platelet-poor (2000 g), platelet-containing (352 g) and platelet-rich plasma (200 g) were prepared and analysed as fresh-frozen and after five defrost-refreeze cycles (to determine the contribution of in vitro platelet degradation). Plasminogen activator inhibitor-1 activity, plasminogen activator inhibitor-1 antigen, tissue plasminogen activator/plasminogen activator inhibitor-1 complex, plasma clot lysis time, β-thromboglobulin and plasma platelet count were analysed. Platelet α-granule release (plasma β-thromboglobulin) showed a significant association with plasminogen activator inhibitor-1 antigen levels but weak associations with plasminogen activator inhibitor-1 activity and a functional marker of fibrinolysis, clot lysis time. Upon dividing the study population into quartiles based on β-thromboglobulin levels, plasminogen activator inhibitor-1 antigen increased significantly across the quartiles while plasminogen activator inhibitor-1 activity and clot lysis time tended to increase in the 4th quartile only. In the follow-up study, plasma plasminogen activator inhibitor-1 antigen was also significantly influenced by platelet count in a concentration-dependent manner. Plasma plasminogen activator inhibitor-1 antigen levels increased further after complete platelet degradation. Residual platelets in plasma significantly influence plasma plasminogen activator inhibitor-1 antigen levels mainly through release of latent plasminogen activator inhibitor-1 with limited effects on plasminogen activator inhibitor-1 activity, tissue plasminogen activator/plasminogen activator inhibitor-1 complex or plasma clot lysis time. Platelets may however also have functional effects on plasma fibrinolytic potential in the presence of high platelet counts, such as in platelet-rich plasma.

  5. Hydrodynamic description of an unmagnetized plasma with multiple ion species. II. Two and three ion species plasmas

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Simakov, Andrei N., E-mail: simakov@lanl.gov; Molvig, Kim

    2016-03-15

    Paper I [A. N. Simakov and K. Molvig, Phys. Plasmas 23, 032115 (2016)] obtained a fluid description for an unmagnetized collisional plasma with multiple ion species. To evaluate collisional plasma transport fluxes, required for such a description, two linear systems of equations need to be solved to obtain corresponding transport coefficients. In general, this should be done numerically. Herein, the general formalism is used to obtain analytical expressions for such fluxes for several specific cases of interest: a deuterium-tritium plasma; a plasma containing two ion species with strongly disparate masses, which agrees with previously obtained results; and a three ionmore » species plasma made of deuterium, tritium, and gold. These results can be used for understanding the behavior of the aforementioned plasmas, or for verifying a code implementation of the general multi-ion formalism.« less

  6. Determination of atenolol in human plasma using ionic-liquid-based ultrasound-assisted in situ solvent formation microextraction followed by high-performance liquid chromatography.

    PubMed

    Zeeb, Mohsen; Farahani, Hadi; Papan, Mohammad Kazem

    2016-06-01

    An efficient analytical method called ionic-liquid-based ultrasound-assisted in situ solvent formation microextraction followed by high-performance liquid chromatography was developed for the determination of atenolol in human plasma. A hydrophobic ionic liquid (1-butyl-3-methylimidazolium hexafluorophosphate) was formed by the addition of a hydrophilic ionic liquid (1-butyl-3-methylimidazolium tetrafluoroborate) to a sample solution containing an ion-pairing agent during microextraction. The analyte was extracted into the ionic liquid phase while the microextraction solvent was dispersed throughout the sample by utilizing ultrasound. The sample was then centrifuged, and the extracting phase retracted into the microsyringe and injected to liquid chromatography. After optimization, the calibration curve showed linearity in the range of 2-750 ng/mL with the regression coefficient corresponding to 0.998. The limits of detection (S/N = 3) and quantification (S/N = 10) were 0.5 and 2 ng/mL, respectively. A reasonable relative recovery range of 90-96.7% and satisfactory intra-assay (4.8-5.1%, n = 6) and interassay (5.0-5.6%, n = 9) precision along with a substantial sample clean-up demonstrated good performance of the procedure. It was applied for the determination of atenolol in human plasma after oral administration and some pharmacokinetic data were obtained. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. Noninvasive Measurement of Steroid Hormones in Zebrafish Holding-Water

    PubMed Central

    Félix, Ana S.; Faustino, Ana I.; Cabral, Eduarda M.

    2013-01-01

    Abstract Zebrafish (Danio rerio) has recently emerged as a new animal model in neuroendocrinology and behavior (e.g., stress physiology and ecotoxicology studies). In these areas, the concentrations of steroid hormones in the blood are often used to study the endocrinological status of individuals. However, due to the small body size of zebrafish, blood sampling is difficult to perform and the amount of plasma obtained per sample for assaying hormones is very small (ca. 1–5 μL), and therefore most studies have been using whole-body hormone concentrations, which implies sacrificing the individuals and hampers sequential sampling of the same individual. Here a noninvasive method to assay steroid hormones from zebrafish holding-water, based on the fact that steroids are released into the fish holding-water through the gills by passive diffusion, is validated. Cortisol and the androgen 11-ketotestosterone (KT) were measured in water samples and compared to plasma levels in the same individuals. Cortisol released to holding-water correlates positively with plasma concentrations, but there was a lack of correlation between KT water and circulating levels. However, KT levels showed a highly significant sex difference that can be used to noninvasively sex individuals. An ACTH challenge test demonstrated that an induced increase in circulating cortisol concentration can be reliably detected in holding-water levels, hence attesting the responsiveness of holding-water levels to fluctuations in circulating levels. PMID:23445429

  8. Circulating microRNAs as Biomarkers for Detection of Autologous Blood Transfusion

    PubMed Central

    Leuenberger, Nicolas; Schumacher, Yorck Olaf; Pradervand, Sylvain; Sander, Thomas; Saugy, Martial; Pottgiesser, Torben

    2013-01-01

    MicroRNAs (miRNAs) are small non-coding RNAs that regulate various biological processes. Cell-free miRNAs measured in blood plasma have emerged as specific and sensitive markers of physiological processes and disease. In this study, we investigated whether circulating miRNAs can serve as biomarkers for the detection of autologous blood transfusion, a major doping technique that is still undetectable. Plasma miRNA levels were analyzed using high-throughput quantitative real-time PCR. Plasma samples were obtained before and at several time points after autologous blood transfusion (blood bag storage time 42 days) in 10 healthy subjects and 10 controls without transfusion. Other serum markers of erythropoiesis were determined in the same samples. Our results revealed a distinct change in the pattern of circulating miRNAs. Ten miRNAs were upregulated in transfusion samples compared with control samples. Among these, miR-30b, miR-30c, and miR-26b increased significantly and showed a 3.9-, 4.0-, and 3.0-fold change, respectively. The origin of these miRNAs was related to pulmonary and liver tissues. Erythropoietin (EPO) concentration decreased after blood reinfusion. A combination of miRNAs and EPO measurement in a mathematical model enhanced the efficiency of autologous transfusion detection through miRNA analysis. Therefore, our results lay the foundation for the development of miRNAs as novel blood-based biomarkers to detect autologous transfusion. PMID:23840438

  9. The search for active Europa plumes in Galileo plasma particle detector data: the E12 flyby

    NASA Astrophysics Data System (ADS)

    Huybrighs, H.; Roussos, E.; Krupp, N.; Fraenz, M.; Futaana, Y.; Barabash, S. V.; Glassmeier, K. H.

    2017-12-01

    Hubble Space Telescope observations of Europa's auroral emissions and transits in front of Jupiter suggest that recurring water vapour plumes originating from Europa's surface might exist. If conclusively proven, the discovery of these plumes would be significant, because Europa's potentially habitable ocean could be studied remotely by taking in-situ samples of these plumes from a flyby mission. The first opportunity to collect in-situ evidence of the plumes will not arise before the early 2030's when ESA's JUICE mission or NASA's Europa Clipper are set to arrive. However, it may be possible that NASA's Galileo mission has already encountered the plumes when it was active in the Jupiter system from 1995 to 2003. It has been suggested that the high plasma densities and anomalous magnetic fields measured during one of the Galileo flybys of Europa (flyby E12) could be connected to plume activity. In the context of the search for Europa plume signatures in Galileo particle data we present an overview of the in-situ plasma particle data obtained by the Galileo spacecraft during the E12 flyby. Focus is in particular on the data obtained with the plasma particle instruments PLS (low energy ions and electrons) and EPD (high energy ions and electrons). We search for signs of an extended exosphere/ionosphere that could be consistent with ongoing plume activity. The PLS data obtained during the E12 flyby show an extended interaction region between Europa and the plasma from Jupiter's magnetosphere, hinting at the existence of an extended ionosphere and exosphere. Furthermore we show how the EPD data are analyzed and modelled in order to evaluate whether a series of energetic ion depletions can be attributed to losses on the moon's surface or its neutral exosphere.

  10. THE NEUROPHARMACOKINETICS OF TEMOZOLOMIDE IN PATIENTS WITH RESECTABLE BRAIN TUMORS: POTENTIAL IMPLICATIONS FOR THE CURRENT APPROACH TO CHEMORADIATION

    PubMed Central

    Portnow, Jana; Badie, Behnam; Chen, Mike; Liu, An; Blanchard, Suzette; Synold, Timothy W.

    2010-01-01

    Purpose Intracerebral microdialysis (ICMD) is an accepted methodology for monitoring changes in neurochemistry from acute brain injury. The goal of this pilot study was to determine the feasibility of using ICMD to examine the neuropharmacokinetics (nPK) of temozolomide (TMZ) in brain interstitium (BI) following oral administration. Experimental Design Patients with primary or metastatic brain tumors had a microdialysis catheter placed in peritumoral brain tissue at the time of surgical debulking. CT scan confirmed the catheter location. Patients received a single oral dose of TMZ (150 mg/m2) on the first post-operative day, serial plasma and ICMD samples were collected over 24 hrs, and TMZ concentrations were determined by tandem mass spectrometry. Results Nine patients were enrolled. Dialysate and plasma samples were successfully collected from 7 of the 9 patients. The mean TMZ area-under-the-concentration-time-curve (AUC) in plasma and BI were 17.1 and 2.7 μg/ml × hr, with an average BI/plasma AUC ratio of 17.8%. The mean peak TMZ concentration in brain was 0.6 ± 0.3 μg/ml, and the mean time to reach peak level in brain was 2.0 ± 0.8 hrs. Conclusions The use of ICMD to measure the nPK of systemically administered chemotherapy is safe and feasible. Concentrations of TMZ in BI obtained by ICMD are consistent with published data obtained in a pre-clinical ICMD model, as well as from clinical studies of cerebrospinal fluid. However, the delayed time required to achieve maximum TMZ concentrations in brain suggests that current chemoradiation regimens may be improved by administering TMZ 2-3 hours before radiation. PMID:19861433

  11. The neuropharmacokinetics of temozolomide in patients with resectable brain tumors: potential implications for the current approach to chemoradiation.

    PubMed

    Portnow, Jana; Badie, Behnam; Chen, Mike; Liu, An; Blanchard, Suzette; Synold, Timothy W

    2009-11-15

    Intracerebral microdialysis (ICMD) is an accepted method for monitoring changes in neurochemistry from acute brain injury. The goal of this pilot study was to determine the feasibility of using ICMD to examine the neuropharmacokinetics of temozolomide in brain interstitium following oral administration. Patients with primary or metastatic brain tumors had a microdialysis catheter placed in peritumoral brain tissue at the time of surgical debulking. Computerized tomography scan confirmed the catheter location. Patients received a single oral dose of temozolomide (150 mg/m2) on the first postoperative day, serial plasma and ICMD samples were collected over 24 hours, and temozolomide concentrations were determined by tandem mass spectrometry. Nine patients were enrolled. Dialysate and plasma samples were successfully collected from seven of the nine patients. The mean temozolomide areas under the concentration-time curve (AUC) in plasma and brain interstitium were 17.1 and 2.7 microg/mL x hour, with an average brain interstitium/plasma AUC ratio of 17.8%. The mean peak temozolomide concentration in the brain was 0.6 +/- 0.3 microg/mL, and the mean time to reach peak level in brain was 2.0 +/- 0.8 hours. The use of ICMD to measure the neuropharmacokinetics of systemically administered chemotherapy is safe and feasible. Concentrations of temozolomide in brain interstitium obtained by ICMD are consistent with published data obtained in a preclinical ICMD model, as well as from clinical studies of cerebrospinal fluid. However, the delayed time required to achieve maximum temozolomide concentrations in brain suggests that current chemoradiation regimens may be improved by administering temozolomide 2 to 3 hours before radiation.

  12. Determination of Rare Earth Elements in Geological Samples Using Laser-Induced Breakdown Spectroscopy (LIBS).

    PubMed

    Bhatt, Chet R; Jain, Jinesh C; Goueguel, Christian L; McIntyre, Dustin L; Singh, Jagdish P

    2018-01-01

    Laser-induced breakdown spectroscopy (LIBS) was used to detect rare earth elements (REEs) in natural geological samples. Low and high intensity emission lines of Ce, La, Nd, Y, Pr, Sm, Eu, Gd, and Dy were identified in the spectra recorded from the samples to claim the presence of these REEs. Multivariate analysis was executed by developing partial least squares regression (PLS-R) models for the quantification of Ce, La, and Nd. Analysis of unknown samples indicated that the prediction results of these samples were found comparable to those obtained by inductively coupled plasma mass spectrometry analysis. Data support that LIBS has potential to quantify REEs in geological minerals/ores.

  13. Investigation of some process parameters using microwave plasma technology for the treatment of radioactive waste

    NASA Astrophysics Data System (ADS)

    Trnovcevic, J.; Schneider, F.; Scherer, U. W.

    2017-02-01

    The production of nuclear energy and the application of other nuclear technologies produce large volumes of low- and intermediate-level radioactive wastes. To investigate a novel means of treating such wastes, plasma is investigated for its efficacy. Plasma treatment promises to simultaneously treat all waste types without any previous sorting or pre-treatment. Microwave-driven plasma torches have the advantage of high-energy efficiency and low-electrode wear. In small-scale experiments, several design variations of an open plasma oven were assembled in order to investigate constraints caused by the materials and oven geometry. The experimental set-up was modified several times in order to test the design characteristics and the variation of plasma-specific proprieties related to the radioactive waste treatment and in order to find a suitable solution with the minimum complexity that allows a representative reproducibility of the results obtained. A plasma torch controlled by a 2.45 GHz microwave signal of up to 200 W was used, employing air as the primary plasma gas with a flow rate of ∼2 L/min. Different organic and inorganic materials in different shapes and sizes were treated besides a standardized mixture resembling mixed wastes from nuclear plants. The results prove that the chosen microwave plasma torch is suitable for a combined combustion and melting of organic and in-organic materials. Investigation of the specimen size to be treated is influential in this process: the power is still too low to melt larger samples, but the temperature is sufficient to treat all kinds of material. When glass particles are added, materials melt together to form an amorphous substance, proving the possibility to vitrify material with this plasma torch. By optimization of the oven configuration, the time needed to combust 25 g of standard sample was reduced by ∼50%. Typical energy efficiencies were found in the range of 8-20% for melting of metal chipping, and ∼90% for melting of zinc powder.

  14. A blood-based screening tool for Alzheimer's disease that spans serum and plasma: findings from TARC and ADNI.

    PubMed

    O'Bryant, Sid E; Xiao, Guanghua; Barber, Robert; Huebinger, Ryan; Wilhelmsen, Kirk; Edwards, Melissa; Graff-Radford, Neill; Doody, Rachelle; Diaz-Arrastia, Ramon

    2011-01-01

    There is no rapid and cost effective tool that can be implemented as a front-line screening tool for Alzheimer's disease (AD) at the population level. To generate and cross-validate a blood-based screener for AD that yields acceptable accuracy across both serum and plasma. Analysis of serum biomarker proteins were conducted on 197 Alzheimer's disease (AD) participants and 199 control participants from the Texas Alzheimer's Research Consortium (TARC) with further analysis conducted on plasma proteins from 112 AD and 52 control participants from the Alzheimer's Disease Neuroimaging Initiative (ADNI). The full algorithm was derived from a biomarker risk score, clinical lab (glucose, triglycerides, total cholesterol, homocysteine), and demographic (age, gender, education, APOE*E4 status) data. Alzheimer's disease. 11 proteins met our criteria and were utilized for the biomarker risk score. The random forest (RF) biomarker risk score from the TARC serum samples (training set) yielded adequate accuracy in the ADNI plasma sample (training set) (AUC = 0.70, sensitivity (SN) = 0.54 and specificity (SP) = 0.78), which was below that obtained from ADNI cerebral spinal fluid (CSF) analyses (t-tau/Aβ ratio AUC = 0.92). However, the full algorithm yielded excellent accuracy (AUC = 0.88, SN = 0.75, and SP = 0.91). The likelihood ratio of having AD based on a positive test finding (LR+) = 7.03 (SE = 1.17; 95% CI = 4.49-14.47), the likelihood ratio of not having AD based on the algorithm (LR-) = 3.55 (SE = 1.15; 2.22-5.71), and the odds ratio of AD were calculated in the ADNI cohort (OR) = 28.70 (1.55; 95% CI = 11.86-69.47). It is possible to create a blood-based screening algorithm that works across both serum and plasma that provides a comparable screening accuracy to that obtained from CSF analyses.

  15. Effect of maternal diabetes on female offspring

    PubMed Central

    Martins, Juliana de Oliveira; Panício, Maurício Isaac; Dantas, Marcos Paulo Suehiro; Gomes, Guiomar Nascimento

    2014-01-01

    Objective To evaluate the effect of maternal diabetes on the blood pressure and kidney function of female offspring, as well as if such changes exacerbate during pregnancy. Methods Diabetes mellitus was induced in female rats with the administration of streptozotocin in a single dose, one week before mating. During pregnancy, blood pressure was measured through plethysmography. On the 20th day of pregnancy, the animals were placed for 24 hours in metabolic cages to obtain urine samples. After the animals were removed from the cages, blood samples were withdrawn. One month after pregnancy, new blood and urine sample were collected. Kidney function was evaluated through proteinuria, plasma urea, plasma creatinine, creatinine excretion rate, urinary flow, and creatinine clearance. Results The female offspring from diabetic mothers showed an increase in blood pressure, and a decrease in glomerular filtration rate in relation to the control group. Conclusion Hyperglycemia during pregnancy was capable of causing an increase in blood pressure and kidney dysfunction in the female offspring. PMID:25628190

  16. Tree ring wood analysis after hydrogen peroxide pressure decomposition with inductively coupled plasma atomic emission spectrometry and electrothermal vaporization

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Matusiewicz, H.; Barnes, R.M.

    1985-02-01

    A method utilizing pressure decomposition to minimize sample pretreatment is described for the inductively coupled plasma atomic emission spectrometric analysis of red spruce and sugar maple. Cores collected from trees growing on Camels Hump Mountain, Vermont, were divided into decade increments in order to monitor the temporal changes in concentrations of 21 elements. Dried wood samples were decomposed in a bomb made of Teflon with 50% hydrogen peroxide heated in an oven at 125/sup 0/C for 4 h. The digestion permitted use of aqueous standards and minimized any potential matrix effects. The element concentrations were obtained sequentially by electrothermal vaporizationmore » ICP-AES using 5 ..mu..L sample aliquots. The method precision varied between 3 and 12%. Elements forming oxyanions (Al, As, Fe, Ge, Mn, Si, V) were found at elevated concentrations during the most recent three decades, while other metal (e.g., Mg, Zn) concentrations were unchanged or decreased. 45 references, 6 tables, 1 figure.« less

  17. Pulmonary disposition and pharmacokinetics of minocycline in adult horses.

    PubMed

    Echeverria, Kate O; Lascola, Kara M; Giguère, Steeve; Foreman, Jonathan H; Austin, Scott A

    2017-11-01

    OBJECTIVE To determine pharmacokinetics and pulmonary disposition of minocycline in horses after IV and intragastric administration. ANIMALS 7 healthy adult horses. PROCEDURES For experiment 1 of the study, minocycline was administered IV (2.2 mg/kg) or intragastrically (4 mg/kg) to 6 horses by use of a randomized crossover design. Plasma samples were obtained before and 16 times within 36 hours after minocycline administration. Bronchoalveolar lavage (BAL) was performed 4 times within 24 hours after minocycline administration for collection of pulmonary epithelial lining fluid (PELF) and BAL cells. For experiment 2, minocycline was administered intragastrically (4 mg/kg, q 12 h, for 5 doses) to 6 horses. Plasma samples were obtained before and 20 times within 96 hours after minocycline administration. A BAL was performed 6 times within 72 hours after minocycline administration for collection of PELF samples and BAL cells. RESULTS Mean bioavailability of minocycline was 48% (range, 35% to 75%). At steady state, mean ± SD maximum concentration (Cmax) of minocycline in plasma was 2.3 ± 1.3 μg/mL, and terminal half-life was 11.8 ± 0.5 hours. Median time to Cmax (Tmax) was 1.3 hours (interquartile range [IQR], 1.0 to 1.5 hours). The Cmax and Tmax of minocycline in the PELF were 10.5 ± 12.8 μg/mL and 9.0 hours (IQR, 5.5 to 12.0 hours), respectively. The Cmax and Tmax for BAL cells were 0.24 ± 0.1 μg/mL and 6.0 hours (IQR, 0 to 6.0 hours), respectively. CONCLUSIONS AND CLINICAL RELEVANCE Minocycline was distributed into the PELF and BAL cells of adult horses.

  18. Multivariate classification of edible salts: Simultaneous Laser-Induced Breakdown Spectroscopy and Laser-Ablation Inductively Coupled Plasma Mass Spectrometry Analysis

    NASA Astrophysics Data System (ADS)

    Lee, Yonghoon; Nam, Sang-Ho; Ham, Kyung-Sik; Gonzalez, Jhanis; Oropeza, Dayana; Quarles, Derrick; Yoo, Jonghyun; Russo, Richard E.

    2016-04-01

    Laser-Induced Breakdown Spectroscopy (LIBS) and Laser-Ablation Inductively Coupled Plasma Mass Spectrometry (LA-ICP-MS), both based on laser ablation sampling, can be employed simultaneously to obtain different chemical fingerprints from a sample. We demonstrated that this analysis approach can provide complementary information for improved classification of edible salts. LIBS could detect several of the minor metallic elements along with Na and Cl, while LA-ICP-MS spectra were used to measure non-metallic and trace heavy metal elements. Principal component analysis using LIBS and LA-ICP-MS spectra showed that their major spectral variations classified the sample salts in different ways. Three classification models were developed by using partial least squares-discriminant analysis based on the LIBS, LA-ICP-MS, and their fused data. From the cross-validation performances and confusion matrices of these models, the minor metallic elements (Mg, Ca, and K) detected by LIBS and the non-metallic (I) and trace heavy metal (Ba, W, and Pb) elements detected by LA-ICP-MS provided complementary chemical information to distinguish particular salt samples.

  19. Preconcentration and determination of rare-earth elements in iron-rich water samples by extraction chromatography and plasma source mass spectrometry (ICP-MS).

    PubMed

    Hernández González, Carolina; Cabezas, Alberto J Quejido; Díaz, Marta Fernández

    2005-11-15

    A 100-fold preconcentration procedure based on rare-earth elements (REEs) separation from water samples with an extraction chromatographic column has been developed. The separation of REEs from matrix elements (mainly Fe, alkaline and alkaline-earth elements) in water samples was performed loading the samples, previously acidified to pH 2.0 with HNO(3), in a 2ml column preconditioned with 20ml 0.01M HNO(3). Subsequently, REEs were quantitatively eluted with 20ml 7M HNO(3). This solution was evaporated to dryness and the final residue was dissolved in 10ml 2% HNO(3) containing 1mugl(-1) of cesium used as internal standard. The solution was directly analysed by inductively coupled plasma mass spectrometry (ICP-MS), using ultrasonic nebulization, obtaining quantification limits ranging from 0.05 to 0.10 ngl(-1). The proposed method has been applied to granitic waters running through fracture fillings coated by iron and manganese oxy-hydroxides in the area of the Ratones (Cáceres, Spain) old uranium mine.

  20. Micro-scale flow system for on-line multielement preconcentration from saliva digests and determination by inductively coupled plasma optical emission spectrometry

    NASA Astrophysics Data System (ADS)

    Menegário, Amauri A.; Fernanda Giné, Maria

    2001-10-01

    A micro-scale flow system is proposed for on-line preconcentration of Cd, Cu, Mn, Ni and Pb in saliva samples and their determination by inductively coupled plasma optical emission spectrometry (ICP-OES). A small column containing 8 μl of AG50W-X8 resin was inserted into the flow system, assembled with capillary tubes and connected to a micro-concentric nebulizer. The elution of the analytes was performed with 3 mol l -1 HCl at a flow rate of 82 μl min -1. The ICP-OES signal acquisition program permits measurements for 5 s in the concentrated portion of the transient elution peaks. A sample volume of 1 ml was required to obtain enrichment factors of 46, 23, 17, 18 and 44 for Cd, Cu, Mn, Ni and Pb, respectively. The relative standard deviations for a 50-μg l -1 multi-analyte solution were ≤6.5%. The recoveries for Cd, Cu, Mn, Ni and Pb in digested human saliva samples were between 86 and 111%. The sample throughput was 24 h -1.

  1. Optimization of the SPME parameters and its online coupling with HPLC for the analysis of tricyclic antidepressants in plasma samples.

    PubMed

    Alves, Claudete; Fernandes, Christian; Dos Santos Neto, Alvaro José; Rodrigues, José Carlos; Costa Queiroz, Maria Eugênia; Lanças, Fernando Mauro

    2006-07-01

    Solid-phase microextraction (SPME)-liquid chromatography (LC) is used to analyze tricyclic antidepressant drugs desipramine, imipramine, nortriptyline, amitriptyline, and clomipramine (internal standard) in plasma samples. Extraction conditions are optimized using a 2(3) factorial design plus a central point to evaluate the influence of the time, temperature, and matrix pH. A Polydimethylsiloxane-divinylbenzene (60-mum film thickness) fiber is selected after the assessment of different types of coating. The chromatographic separation is realized using a C(18) column (150 x 4.6 mm, 5-microm particles), ammonium acetate buffer (0.05 mol/L, pH 5.50)-acetonitrile (55:45 v/v) with 0.1% of triethylamine as mobile phase and UV-vis detection at 214 nm. Among the factorial design conditions evaluated, the best results are obtained at a pH 11.0, temperature of 30 degrees C, and extraction time of 45 min. The proposed method, using a lab-made SPME-LC interface, allowed the determination of tricyclic antidepressants in in plasma at therapeutic concentration levels.

  2. Electrochemical approach for acute myocardial infarction diagnosis based on direct antibodies-free analysis of human blood plasma.

    PubMed

    Suprun, Elena V; Saveliev, Anatoly A; Evtugyn, Gennady A; Lisitsa, Alexander V; Bulko, Tatiana V; Shumyantseva, Victoria V; Archakov, Alexander I

    2012-03-15

    A novel direct antibodies-free electrochemical approach for acute myocardial infarction (AMI) diagnosis has been developed. For this purpose, a combination of the electrochemical assay of plasma samples with chemometrics was proposed. Screen printed carbon electrodes modified with didodecyldimethylammonium bromide were used for plasma charactrerization by cyclic (CV) and square wave voltammetry and square wave (SWV) voltammetry. It was shown that the cathodic peak in voltammograms at about -250 mV vs. Ag/AgCl can be associated with AMI. In parallel tests, cardiac myoglobin and troponin I, the AMI biomarkers, were determined in each sample by RAMP immunoassay. The applicability of the electrochemical testing for AMI diagnostics was confirmed by statistical methods: generalized linear model (GLM), linear discriminant analysis (LDA) and quadratic discriminant analysis (QDA), artificial neural net (multi-layer perception, MLP), and support vector machine (SVM), all of which were created to obtain the "True-False" distribution prediction where "True" and "False" are, respectively, positive and negative decision about an illness event. Copyright © 2011 Elsevier B.V. All rights reserved.

  3. Bacterial adhesion on conventional and self-ligating metallic brackets after surface treatment with plasma-polymerized hexamethyldisiloxane

    PubMed Central

    Tupinambá, Rogerio Amaral; Claro, Cristiane Aparecida de Assis; Pereira, Cristiane Aparecida; Nobrega, Celestino José Prudente; Claro, Ana Paula Rosifini Alves

    2017-01-01

    ABSTRACT Introduction: Plasma-polymerized film deposition was created to modify metallic orthodontic brackets surface properties in order to inhibit bacterial adhesion. Methods: Hexamethyldisiloxane (HMDSO) polymer films were deposited on conventional (n = 10) and self-ligating (n = 10) stainless steel orthodontic brackets using the Plasma-Enhanced Chemical Vapor Deposition (PECVD) radio frequency technique. The samples were divided into two groups according to the kind of bracket and two subgroups after surface treatment. Scanning Electron Microscopy (SEM) analysis was performed to assess the presence of bacterial adhesion over samples surfaces (slot and wings region) and film layer integrity. Surface roughness was assessed by Confocal Interferometry (CI) and surface wettability, by goniometry. For bacterial adhesion analysis, samples were exposed for 72 hours to a Streptococcus mutans solution for biofilm formation. The values obtained for surface roughness were analyzed using the Mann-Whitney test while biofilm adhesion were assessed by Kruskal-Wallis and SNK test. Results: Significant statistical differences (p< 0.05) for surface roughness and bacterial adhesion reduction were observed on conventional brackets after surface treatment and between conventional and self-ligating brackets; no significant statistical differences were observed between self-ligating groups (p> 0.05). Conclusion: Plasma-polymerized film deposition was only effective on reducing surface roughness and bacterial adhesion in conventional brackets. It was also noted that conventional brackets showed lower biofilm adhesion than self-ligating brackets despite the absence of film. PMID:28902253

  4. Use of refractometry for determination of psittacine plasma protein concentration.

    PubMed

    Cray, Carolyn; Rodriguez, Marilyn; Arheart, Kristopher L

    2008-12-01

    Previous studies have demonstrated both poor and good correlation of total protein concentrations in various avian species using refractometry and biuret methodologies. The purpose of the current study was to compare these 2 techniques of total protein determination using plasma samples from several psittacine species and to determine the effect of cholesterol and other solutes on refractometry results. Total protein concentration in heparinized plasma samples without visible lipemia was analyzed by refractometry and an automated biuret method on a dry reagent analyzer (Ortho 250). Cholesterol, glucose, and uric acid concentrations were measured using the same analyzer. Results were compared using Deming regression analysis, Bland-Altman bias plots, and Spearman's rank correlation. Correlation coefficients (r) for total protein results by refractometry and biuret methods were 0.49 in African grey parrots (n=28), 0.77 in Amazon parrots (20), 0.57 in cockatiels (20), 0.73 in cockatoos (36), 0.86 in conures (20), and 0.93 in macaws (38) (P< or =.01). Cholesterol concentration, but not glucose or uric acid concentrations, was significantly correlated with total protein concentration obtained by refractometry in Amazon parrots, conures, and macaws (n=25 each, P<.05), and trended towards significance in African grey parrots and cockatoos (P=.06). Refractometry can be used to accurately measure total protein concentration in nonlipemic plasma samples from some psittacine species. Method and species-specific reference intervals should be used in the interpretation of total protein values.

  5. An automated method for the analysis of phenolic acids in plasma based on ion-pairing micro-extraction coupled on-line to gas chromatography/mass spectrometry with in-liner derivatisation.

    PubMed

    Peters, Sonja; Kaal, Erwin; Horsting, Iwan; Janssen, Hans-Gerd

    2012-02-24

    A new method is presented for the analysis of phenolic acids in plasma based on ion-pairing 'Micro-extraction in packed sorbent' (MEPS) coupled on-line to in-liner derivatisation-gas chromatography-mass spectrometry (GC-MS). The ion-pairing reagent served a dual purpose. It was used both to improve extraction yields of the more polar analytes and as the methyl donor in the automated in-liner derivatisation method. In this way, a fully automated procedure for the extraction, derivatisation and injection of a wide range of phenolic acids in plasma samples has been obtained. An extensive optimisation of the extraction and derivatisation procedure has been performed. The entire method showed excellent repeatabilities of under 10% and linearities of 0.99 or better for all phenolic acids. The limits of detection of the optimised method for the majority of phenolic acids were 10ng/mL or lower with three phenolic acids having less-favourable detection limits of around 100 ng/mL. Finally, the newly developed method has been applied in a human intervention trial in which the bioavailability of polyphenols from wine and tea was studied. Forty plasma samples could be analysed within 24h in a fully automated method including sample extraction, derivatisation and gas chromatographic analysis. Copyright © 2011 Elsevier B.V. All rights reserved.

  6. Determination of free and total (free plus protein-bound) melatonin in plasma and cerebrospinal fluid by high-performance liquid chromatography with fluorescence detection.

    PubMed

    Rizzo, Vittoria; Porta, Camillo; Moroni, Mauro; Scoglio, Enrico; Moratti, Remigio

    2002-07-05

    A simple, sensitive and accurate method for the estimation of free and total (free plus protein-bound) melatonin (MLT) in human plasma and cerebrospinal fluid (CSF) is described. Via Chem-Elut cartridges, free and total MLT (the latter obtained after a deproteinization step) were quantified in dichloromethane-extracted samples and analyzed in one chromatographic run by high-performance liquid chromatography (HPLC) with fluorimetric detection. The column used was an Extrasil ODS-2 (3 microm, 150 x 4.6 mm I.D.), while the mobile phase consisted of 75 mM sodium acetate-acetonitrile (72:28, v/v) (pH 5.0). Repeatability and reproducibility of the method were 3.24 and 9.4%, respectively. The recovery of melatonin from plasma and CSF was 99.9+/-4.0% for non-deproteinized samples and 93.2+/-4.8% for deproteinized samples. The detection limit of the assay was 0.5 pg/ml. In human plasma, the mean+/-SD concentrations in the darkness period were 23.18+/-7.44 pg/ml for free melatonin and 82.5+/-36.48 pg/ml for total melatonin, while the lowest concentrations detected during daytime were 2.23+/-2.22 and 7.40+/-5.68 pg/ml, respectively. Detection of MLT in CSF was 5.01+/-2.31 and 28.55+/-6.95 pg/ml for the free and total fraction, respectively.

  7. Tin speciation in the femtogram range in open ocean seawater by gas chromatography/inductively coupled plasma mass spectrometry using a shield torch at normal plasma conditions.

    PubMed

    Tao, H; Rajendran, R B; Quetel, C R; Nakazato, T; Tominaga, M; Miyazaki, A

    1999-10-01

    A sensitive method for the determination of ultratrace organotin species in seawater is described. The merits and demerits of derivatization methods using Grignard reagent or sodium tetraethylborate (NaBEt4) were evaluated in terms of derivatization efficiency, applicability to the programmed temperature vaporization (PTV) method, and procedural blanks. The sensitivity of the gas chromatography/inductively coupled plasma mass spectrometry (GC/ICPMS) was improved by more than 100-fold by operating the shield torch at normal plasma conditions, compared with that obtained without using it. The absolute detection limit as tin reached subfemtogram (fg) levels. Furthermore, the detection limit in terms of relative concentration was improved 100-fold by using the PTV method, which enabled the injection of a large sample volume of as much as 100 microL without loss of analyte. When the organotin species in seawater were extracted into hexane with a preconcentration factor of 1000 after ethylation with NaBEt4 and a 100 microL aliquot of the extract was injected into the GC, the instrumental detection limit in relative concentration reached 0.01 pg/L in original seawater. Sources of contamination of organotin species during the sample preparation were examined, and a purification method of NaBEt4 was developed. Finally, the method was successfully applied to open ocean seawater samples containing organotin species at the level of 1-100 pg/L.

  8. Introduction of a rapid, simple radioimmunoassay and quality control scheme for thyroxine.

    PubMed Central

    Nye, L; Hassan, M; Willmott, E; Landon, J

    1976-01-01

    A simple radioimmunoassay has been developed for service purposes to determine serum total thyroxine levels. Only three additions are required, of standard or sample, labelled thyroxine and antibody in polyethylene glycol. After 2 hours' incubation at room temperature the antibody-bound and free fractions are separated by centrifugation. Serum total thyroxine levels were measured in 195 euthyroid subjects and it was established that normal values lay within the range 57 to 155 nmol/1. Serial blood samples taken over a 24-hour period, from 11 subjects, indicated that there was no circadian rhythm so that samples for total thyroxine assay can be taken at any time of the day. Similar results were obtained using serum or plasma. Satisfactory results were obtained for three quality control sera when measured by seven different laboratories using this method. PMID:932232

  9. Detection of hepatitis B virus infection markers in dried plasma spots among patients in Congo-Brazzaville.

    PubMed

    Alidjinou, Enagnon Kazali; Moukassa, Donatien; Sané, Famara; Twagirimana Nyenyeli, Séraphin; Akoko, Estina Chandrelle; Mountou, Michèle Valy; Bocket, Laurence; Ibara, Jean-Rosaire; Hober, Didier

    2014-03-01

    The detection of hepatitis B virus (HBV) infection markers by using dried plasma spots from 32 patients living in Congo has been assessed. Considering frozen plasma samples as gold standard, the sensitivity and specificity of HBV serologic markers detection in dried plasma eluted from filter paper were 100%. The sensitivity and the specificity of HBV DNA detection reached 96% and 100%, respectively, with plasma samples dried on filter paper compared to standard samples. Dried plasma samples can represent an alternative to conventional sampling for HBV detection and management of the infection in developing countries. Copyright © 2014 Elsevier Inc. All rights reserved.

  10. Microwave-assisted wet digestion with H2O2 at high temperature and pressure using single reaction chamber for elemental determination in milk powder by ICP-OES and ICP-MS.

    PubMed

    Muller, Edson I; Souza, Juliana P; Muller, Cristiano C; Muller, Aline L H; Mello, Paola A; Bizzi, Cezar A

    2016-08-15

    In this work a green digestion method which only used H2O2 as an oxidant and high temperature and pressure in the single reaction chamber system (SRC-UltraWave™) was applied for subsequent elemental determination by inductively coupled plasma-based techniques. Milk powder was chosen to demonstrate the feasibility and advantages of the proposed method. Samples masses up to 500mg were efficiently digested, and the determination of Ca, Fe, K, Mg and Na was performed by inductively coupled plasma optical emission spectrometry (ICP-OES), while trace elements (B, Ba, Cd, Cu, Mn, Mo, Pb, Sr and Zn) were determined by inductively coupled plasma mass spectrometry (ICP-MS). Residual carbon (RC) lower than 918mgL(-1) of C was obtained for digests which contributed to minimizing interferences in determination by ICP-OES and ICP-MS. Accuracy was evaluated using certified reference materials NIST 1549 (non-fat milk powder certified reference material) and NIST 8435 (whole milk powder reference material). The results obtained by the proposed method were in agreement with the certified reference values (t-test, 95% confidence level). In addition, no significant difference was observed between results obtained by the proposed method and conventional wet digestion using concentrated HNO3. As digestion was performed without using any kind of acid, the characteristics of final digests were in agreement with green chemistry principles when compared to digests obtained using conventional wet digestion method with concentrated HNO3. Additionally, H2O2 digests were more suitable for subsequent analysis by ICP-based techniques due to of water being the main product of organic matrix oxidation. The proposed method was suitable for quality control of major components and trace elements present in milk powder in consonance with green sample preparation. Copyright © 2016 Elsevier B.V. All rights reserved.

  11. Anti-glucagon-like peptide-1 immunoreactivity in samples of blood and ileum obtained from neonatal and adult alpacas.

    PubMed

    Smith, Courtney C; Cebra, Christopher K; Heidel, Jerry R; Stang, Bernadette V

    2013-11-01

    To compare numbers of L cells in intestinal samples and blood concentrations of glucagon-like peptide (GLP)-1 between neonatal and mature alpacas. Intestinal samples from carcasses of 4 suckling crias and 4 postweaning alpacas for immunohistochemical analysis and blood samples from 32 suckling crias and 19 healthy adult alpacas for an ELISA. Immunohistochemical staining was conducted in accordance with Oregon State University Veterinary Diagnostic Laboratory standard procedures with a rabbit polyclonal anti-GLP-1 primary antibody. Stained cells with staining results in ileal tissue were counted in 20 fields by 2 investigators, and the mean value was calculated. For quantification of GLP-1 concentrations, blood samples were collected into tubes containing a dipeptidyl peptidase-4 inhibitor. Plasma samples were tested in duplicate with a commercial GLP-1 ELISA validated for use in alpacas. Counts of stained cells (mean ± SD, 50 ± 18 cells) and plasma GLP-1 concentrations (median, 0.086 ng/mL; interquartile range, 0.061 to 0.144 ng/mL) were higher for suckling alpacas than for postsuckling alpacas (stained cells, 26 ± 4 cells; plasma GLP-1 concentration, median, 0.034 ng/mL; interquartile range, 0.015 to 0.048 ng/mL). Older alpacas had lower numbers of L cells in intestinal tissues and lower blood concentrations of GLP-1 than those in neonates. These findings suggested that there may be a decrease in the contribution of GLP-1 to insulin production in adult alpacas, compared with the contribution in neonates.

  12. Differential stability of therapeutic peptides with different proteolytic cleavage sites in blood, plasma and serum.

    PubMed

    Böttger, Roland; Hoffmann, Ralf; Knappe, Daniel

    2017-01-01

    Proteolytic degradation of peptide-based drugs is often considered as major weakness limiting systemic therapeutic applications. Therefore, huge efforts are typically devoted to stabilize sequences against proteases present in serum or plasma, obtained as supernatants after complete blood coagulation or centrifugation of blood supplemented with anticoagulants, respectively. Plasma and serum are reproducibly obtained from animals and humans allowing consistent for clinical analyses and research applications. However, the spectrum of active or activated proteases appears to vary depending on the activation of proteases and cofactors during coagulation (serum) or inhibition of such enzymes by anticoagulants (plasma), such as EDTA (metallo- and Ca2+-dependent proteases) and heparin (e.g. thrombin, factor Xa). Here, we studied the presumed effects on peptide degradation by taking blood via cardiac puncture of CD-1 mice using a syringe containing a peptide solution. Due to absence of coagulation activators (e.g. glass surfaces and damaged cells), visible blood clotting was prevented allowing to study peptide degradation for one hour. The remaining peptide was quantified and the degradation products were identified using mass spectrometry. When the degradation rates (half-life times) were compared to serum derived freshly from the same animal and commercial serum and plasma samples, peptides of three different families showed indeed considerably different stabilities. Generally, peptides were faster degraded in serum than in plasma, but surprisingly all peptides were more stable in fresh blood and the order of degradation rates among the peptides varied among the six different incubation experiments. This indicates, that proteolytic degradation of peptide-based therapeutics may often be misleading stimulating efforts to stabilize peptides at degradation sites relevant only in vitro, i.e., for serum or plasma stability assays, but of lower importance in vivo.

  13. Partial microwave-assisted wet digestion of animal tissue using a baby-bottle sterilizer for analyte determination by inductively coupled plasma optical emission spectrometry

    NASA Astrophysics Data System (ADS)

    Matos, Wladiana O.; Menezes, Eveline A.; Gonzalez, Mário H.; Costa, Letícia M.; Trevizan, Lilian C.; Nogueira, Ana Rita A.

    2009-06-01

    A procedure for partial digestion of bovine tissue is proposed using polytetrafluoroethylene (PTFE) micro-vessels inside a baby-bottle sterilizer under microwave radiation for multi-element determination by inductively coupled plasma optical emission spectrometry (ICP OES). Samples were directly weighed in laboratory-made polytetrafluoroethylene vessels. Nitric acid and hydrogen peroxide were added to the uncovered vessels, which were positioned inside the baby-bottle sterilizer, containing 500 mL of water. The hydrogen peroxide volume was fixed at 100 µL. The system was placed in a domestic microwave oven and partial digestion was carried out for the determination of Ca, Cu, Fe, Mg, Mn and Zn by inductively coupled plasma optical emission spectrometry. The single-vessel approach was used in the entire procedure, to minimize contamination in trace analysis. Better recoveries and lower residual carbon content (RCC) levels were obtained under the conditions established through a 2 4-1 fractional factorial design: 650 W microwave power, 7 min digestion time, 50 µL nitric acid and 50 mg sample mass. The digestion efficiency was ascertained according to the residual carbon content determined by inductively coupled plasma optical emission spectrometry. The accuracy of the proposed procedure was checked against two certified reference materials.

  14. Development and full validation of an UPLC-MS/MS method for the quantification of the plant-derived alkaloid indirubin in rat plasma.

    PubMed

    Jähne, Evelyn A; Sampath, Chethan; Butterweck, Veronika; Hamburger, Matthias; Oufir, Mouhssin

    2016-09-05

    An UPLC-MS/MS method for the quantification of indirubin in lithium heparinized rat plasma was developed and validated according to current international guidelines. Indirubin was extracted from rat plasma by using Waters Ostro™ pass-through sample preparation plates. The method was validated with a LLOQ of 5.00ng/mL and an ULOQ of 500ng/mL. The calibration curve was fitted by least-square quadratic regression, and a weighting factor of 1/X was applied. Recoveries of indirubin and I.S. were consistent and ≥75.5%. Stability studies demonstrated that indirubin was stable in lithium heparinized rat plasma for at least 3 freeze/thaw cycles, for 3h at RT, for 96h in the autosampler at 10°C, and for 84days when stored below -65°C. Preliminary pharmacokinetic (PK) data were obtained from Sprague Dawley rats after intravenous administration of indirubin (2mg/kg b.w.) and blood sampling up to 12h after injection. PK parameters were determined by non-compartmental analysis. Indirubin had a half-life (t1/2) of 35min, and a relatively high clearance (CL) of 2.71L/h/kg. Copyright © 2016 Elsevier B.V. All rights reserved.

  15. Development of SPME-LC-MS method for screening of eight beta-blockers and bronchodilators in plasma and urine samples.

    PubMed

    Goryński, Krzysztof; Kiedrowicz, Alicja; Bojko, Barbara

    2016-08-05

    The current work describes the development and validation of a simple, efficient, and fast method using solid phase microextraction coupled to liquid chromatography-tandem mass spectrometry (SPME-LC-MS/MS) for the concomitant measurement of eight beta-blockers and bronchodilators in plasma and urine. The presented assay enables quantitative determination of acebutolol, atenolol, fenoterol, nadolol, pindolol, procaterol, sotalol, and timolol. In this work, samples were prepared on a high-throughput platform using the 96-well plate format of the thin film solid phase microextraction (TFME) system, and a biocompatible extraction phase made of hydrophilic-lipophilic balance particles. Analytes were separated on a pentafluorophenyl column (100mm×2.1mm, 3μm) by gradient elution using an UPLC Nexera coupled with an LCMS-8060 mass spectrometer. The mobile phase consisted of water-acetonitrile (0.1% formic acid) at a flow rate of 0.4mLmin(-1). The linearity of the method was checked within therapeutic blood-plasma concentrations, and shown to adequately reflect typically expected concentrations of future study samples. Post-extraction addition experiments showed that the matrix effect ranged in plasma from 98% for procaterol to 115% for nadolol, and in urine, from 85% for nadolol and pindolol to 119% for atenolol. The method was successfully validated using Food and Drug Administration (FDA) guidelines, and met all acceptance criteria for bioanalytical assays at five concentration levels for all selected drugs. The final protocol can be successfully applied for monitoring concentrations of the selected drugs in both plasma and urine matrices obtained from patients or athletes. Copyright © 2016 Elsevier B.V. All rights reserved.

  16. Adhesive blood microsampling systems for steroid measurement via LC-MS/MS in the rat.

    PubMed

    Heussner, Kirsten; Rauh, Manfred; Cordasic, Nada; Menendez-Castro, Carlos; Huebner, Hanna; Ruebner, Matthias; Schmidt, Marius; Hartner, Andrea; Rascher, Wolfgang; Fahlbusch, Fabian B

    2017-04-01

    Liquid Chromatography Tandem Mass Spectrometry (LC-MS/MS) allows for the direct analysis of multiple hormones in a single probe with minimal sample volume. Rodent-based animal studies strongly rely on microsampling, such as the dry blood spot (DBS) method. However, DBS suffers the drawback of hematocrit-dependence (non-volumetric). Hence, novel volumetric microsampling techniques were introduced recently, allowing sampling of fixed accurate volumes. We compared these methods for steroid analysis in the rat to improve inter-system comparability. We analyzed steroid levels in blood using the absorptive microsampling devices Whatman® 903 Protein Saver Cards, Noviplex™ Plasma Prep Cards and the Mitra™ Microsampling device and compared the obtained results to the respective EDTA plasma levels. Quantitative steroid analysis was performed via LC-MS/MS. For the determination of the plasma volume factor for each steroid, their levels in pooled blood samples from each human adults and rats (18weeks) were compared and the transferability of these factors was evaluated in a new set of juvenile (21days) and adult (18weeks) rats. Hematocrit was determined concomitantly. Using these approaches, we were unable to apply one single volume factor for each steroid. Instead, plasma volume factors had to be adjusted for the recovery rate of each steroid and device individually. The tested microsampling systems did not allow the use of one single volume factor for adult and juvenile rats based on an unexpectedly strong hematocrit-dependency and other steroid specific (pre-analytic) factors. Our study provides correction factors for LC-MS/MS steroid analysis of volumetric and non-volumetric microsampling systems in comparison to plasma. It argues for thorough analysis of chromatographic effects before the use of novel volumetric systems for steroid analysis. Copyright © 2017 Elsevier Inc. All rights reserved.

  17. Surface Texturing-Plasma Nitriding Duplex Treatment for Improving Tribological Performance of AISI 316 Stainless Steel

    PubMed Central

    Lin, Naiming; Liu, Qiang; Zou, Jiaojuan; Guo, Junwen; Li, Dali; Yuan, Shuo; Ma, Yong; Wang, Zhenxia; Wang, Zhihua; Tang, Bin

    2016-01-01

    Surface texturing-plasma nitriding duplex treatment was conducted on AISI 316 stainless steel to improve its tribological performance. Tribological behaviors of ground 316 substrates, plasma-nitrided 316 (PN-316), surface-textured 316 (ST-316), and duplex-treated 316 (DT-316) in air and under grease lubrication were investigated using a pin-on-disc rotary tribometer against counterparts of high carbon chromium bearing steel GCr15 and silicon nitride Si3N4 balls. The variations in friction coefficient, mass loss, and worn trace morphology of the tested samples were systemically investigated and analyzed. The results showed that a textured surface was formed on 316 after electrochemical processing in a 15 wt % NaCl solution. Grooves and dimples were found on the textured surface. As plasma nitriding was conducted on a 316 substrate and ST-316, continuous and uniform nitriding layers were successfully fabricated on the surfaces of the 316 substrate and ST-316. Both of the obtained nitriding layers presented thickness values of more than 30 μm. The nitriding layers were composed of iron nitrides and chromium nitride. The 316 substrate and ST-316 received improved surface hardness after plasma nitriding. When the tribological tests were carried out under dry sliding and grease lubrication conditions, the tested samples showed different tribological behaviors. As expected, the DT-316 samples revealed the most promising tribological properties, reflected by the lowest mass loss and worn morphologies. The DT-316 received the slightest damage, and its excellent tribological performance was attributed to the following aspects: firstly, the nitriding layer had high surface hardness; secondly, the surface texture was able to capture wear debris, store up grease, and then provide continuous lubrication. PMID:28773996

  18. Quantification of drugs in plasma without primary reference standards by liquid chromatography-chemiluminescence nitrogen detection: application to tramadol metabolite ratios.

    PubMed

    Ojanperä, Suvi; Rasanen, Ilpo; Sistonen, Johanna; Pelander, Anna; Vuori, Erkki; Ojanperä, Ilkka

    2007-08-01

    Lack of availability of reference standards for drug metabolites, newly released drugs, and illicit drugs hinders the analysis of these substances in biologic samples. To counter this problem, an approach is presented here for quantitative drug analysis in plasma without primary reference standards by liquid chromatography-chemiluminescence nitrogen detection (LC-CLND). To demonstrate the feasibility of the method, metabolic ratios of the opioid drug tramadol were determined in the setting of a pharmacogenetic study. Four volunteers were given a single 100-mg oral dose of tramadol, and a blood sample was collected from each subject 1 hour later. Tramadol, O-desmethyltramadol, and nortramadol were determined in plasma by LC-CLND without reference standards and by a gas chromatography-mass spectrometry reference method. In contrast to previous CLND studies lacking an extraction step, a liquid-liquid extraction system was created for 5-mL plasma samples using n-butyl chloride-isopropyl alcohol (98 + 2) at pH 10. Extraction recovery estimation was based on model compounds chosen according to their similar physicochemical characteristics (retention time, pKa, logD). Instrument calibration was performed with a single secondary standard (caffeine) using the equimolar response of the detector to nitrogen. The mean differences between the results of the LC-CLND and gas chromatography-mass spectrometry methods for tramadol, O-desmethyltramadol, and nortramadol were 8%, 32%, and 19%, respectively. The sensitivity of LC-CLND was sufficient for therapeutic concentrations of tramadol and metabolites. A good correlation was obtained between genotype, expressed by the number of functional genes, and the plasma metabolite ratios. This experiment suggests that a recovery-corrected LC-CLND analysis produces sufficiently accurate results to be useful in a clinical context, particularly in instances in which reference standards are not readily accessible.

  19. Haematology and plasma chemistry of the red top ice blue mbuna cichlid (Metriaclima greshakei).

    PubMed

    Snellgrove, Donna L; Alexander, Lucille G

    2011-10-01

    Clinical haematology and blood plasma chemistry can be used as a valuable tool to provide substantial diagnostic information for fish. A wide range of parameters can be used to assess nutritional status, digestive function, disease identification, routine metabolic levels, general physiological status and even the assessment and management of wild fish populations. However to evaluate such data accurately, baseline reference intervals for each measurable parameter must be established for the species of fish in question. Baseline data for ornamental fish species are limited, as research is more commonly conducted using commercially cultured fish. Blood samples were collected from sixteen red top ice blue cichlids (Metriaclima greshakei), an ornamental freshwater fish, to describe a range of haematology and plasma chemistry parameters. Since this cichlid is fairly large in comparison with most tropical ornamental fish, two independent blood samples were taken to assess a large range of parameters. No significant differences were noted between sample periods for any parameter. Values obtained for a large number of parameters were similar to those established for other closely related fish species such as tilapia (Oreochromis spp.). In addition to reporting the first set of blood values for M. Greshakei, to our knowledge, this study highlights the possibility of using previously established data for cultured cichlid species in studies with ornamental cichlid fish.

  20. Casingless down-hole for sealing an ablation volume and obtaining a sample for analysis

    DOEpatents

    Noble, D.T.; Braymen, S.D.; Anderson, M.S.

    1996-10-01

    A casing-less down hole sampling system for acquiring a subsurface sample for analysis using an inductively coupled plasma system is disclosed. The system includes a probe which is pushed into the formation to be analyzed using a hydraulic ram system. The probe includes a detachable tip member which has a soil point and a barb, with the soil point aiding the penetration of the earth, and the barb causing the tip member to disengage from the probe and remain in the formation when the probe is pulled up. The probe is forced into the formation to be tested, and then pulled up slightly, to disengage the tip member and expose a column of the subsurface formation to be tested. An instrumentation tube mounted in the probe is then extended outward from the probe to longitudinally extend into the exposed column. A balloon seal mounted on the end of the instrumentation tube allows the bottom of the column to be sealed. A source of laser radiation is emitted from the instrumentation tube to ablate a sample from the exposed column. The instrumentation tube can be rotated in the probe to sweep the laser source across the surface of the exposed column. An aerosol transport system carries the ablated sample from the probe to the surface for testing in an inductively coupled plasma system. By testing at various levels in the down-hole as the probe is extracted from the soil, a profile of the subsurface formation may be obtained. 9 figs.

Top