Plasma volume status predicts prognosis in patients with acute heart failure syndromes.
Yoshihisa, Akiomi; Abe, Satoshi; Sato, Yu; Watanabe, Shunsuke; Yokokawa, Tetsuro; Miura, Shunsuke; Misaka, Tomofumi; Sato, Takamasa; Suzuki, Satoshi; Oikawa, Masayoshi; Kobayashi, Atsushi; Yamaki, Takayoshi; Kunii, Hiroyuki; Saitoh, Shu-Ichi; Takeishi, Yasuchika
2017-01-01
The intravascular compartment is known as the plasma volume, and the extravascular compartment represents fluid within the interstitial space. Plasma volume expansion is a major symptom of heart failure. The aim of the current study was to investigate the impact of plasma volume status on the prognosis of acute heart failure syndromes. We analyzed 1115 patients with acute heart failure syndromes who were admitted to our hospital. These patients were divided into three groups based on their plasma volume status at admission: first tertile (plasma volume status <41.9%, n = 371), second tertile (41.9%⩽ plasma volume status <49.0%, n = 372), and third tertile (49.0%⩽ plasma volume status, n = 372). Plasma volume status was defined as follows: actual plasma volume = (1 - hematocrit) × [ a + ( b × body weight)] ( a=1530 in males and a=864 in females, b=41.0 in males and b=47.9 in females); ideal plasma volume = c × body weight ( c=39 in males and c=40 in females); and plasma volume status = [(actual plasma volume - ideal plasma volume)/ideal plasma volume] × 100 (%). In the Kaplan-Meier analysis, all-cause mortality, cardiac mortality and cardiac events increased progressively from the first to third tertile ( p <0.001, respectively). In the Cox proportional hazard analysis, after adjusting for potential confounding factors, plasma volume status was an independent predictor of all-cause mortality (hazard ratio 1.429, p < 0.001), cardiac mortality (hazard ratio 1.416, p = 0.001) and cardiac events (hazard ratio 1.207, p = 0.004). Increased congestion is associated with increased morbidity and mortality in heart failure patients. Plasma volume status, which represents intravascular compartment and congestion, can identify poor prognosis in patients with acute heart failure syndromes.
Paulauskas, Felix L.; Bonds, Truman
2016-09-20
A plasma treatment method that includes providing treatment chamber including an intermediate heating volume and an interior treatment volume. The interior treatment volume contains an electrode assembly for generating a plasma and the intermediate heating volume heats the interior treatment volume. A work piece is traversed through the treatment chamber. A process gas is introduced to the interior treatment volume of the treatment chamber. A plasma is formed with the electrode assembly from the process gas, wherein a reactive species of the plasma is accelerated towards the fiber tow by flow vortices produced in the interior treatment volume by the electrode assembly.
Low Plasma Volume in Normotensive Formerly Preeclamptic Women Predisposes to Hypertension.
Scholten, Ralph R; Lotgering, Fred K; Hopman, Maria T; Van Dijk, Arie; Van de Vlugt, Maureen; Janssen, Mirian C H; Spaanderman, Marc E A
2015-11-01
Formerly preeclamptic women are at risk for cardiovascular disease. Low plasma volume may reflect latent hypertension and potentially links preeclampsia with chronic cardiovascular disease. We hypothesized that low plasma volume in normotensive formerly preeclamptic women predisposes to hypertension. We longitudinally studied n=104 formerly preeclamptic women in whom plasma volume was measured 3 to 30 months after the preeclamptic pregnancy. Cardiovascular variables were assessed at 2 points in time (3-30 months postpartum and 2-5 years thereafter). Study population was divided into low plasma volume (≤1373 mL/m(2)) and normal plasma volume (>1373 mL/m(2)). Primary end point was hypertension at the second visit: defined as ≥140 mm Hg systolic or ≥90 mm Hg diastolic. Secondary outcome of this study was change in traditional cardiovascular risk profile between visits. Variables correlating univariately with change in blood pressure between visits were introduced in regression analysis. Eighteen of 104 (17%) formerly preeclamptic women who were normotensive at first visit had hypertension at second evaluation 2 to 5 years later. Hypertension developed more often in women with low plasma volume (10/35 [29%]) than in women with normal plasma volume (8/69 [12%]; odds ratio, 3.2; 95% confidence interval, 1.4-8.6). After adjustments, relationship between plasma volume status and subsequent hypertension persisted (adjusted odds ratio, 3.0; 95% confidence interval, 1.1-8.5). Mean arterial pressure at second visit correlated inverse linearly with plasma volume (r=-0.49; P<0.01). Initially normotensive formerly preeclamptic women have 17% chance to develop hypertension within 5 years. Women with low plasma volume have higher chance to develop hypertension than women with normal plasma volume. Clinically, follow-up of blood pressure seems warranted in women with history of preeclampsia, even when initially normotensive. © 2015 American Heart Association, Inc.
Influence of plasma volume expansion with saline on the plasma levels of an ouabain-like factor
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rauch, A.L.; Morris, M.; Buckalew, V.M. Jr.
1986-03-05
Plasma volume expansion with saline activates the cardiopulmonary baroreflex and causes the release of natriuretic factors(s). One putative natriuretic factor has ouabain-like activity (OLA). To examine the relationship between this factor and plasma volume expansion, the OLA of plasma was examined in rats that were volume expanded with 0.9% saline at a rate of 150..mu..l/min/100 g of rat for 15, 30, 60 and 120 minutes. Plasma OLA was quantitated with a radioreceptor assay utilizing /sup 3/H-ouabain and erythrocytes ghosts. The OLA and hematocrit of control rats were 18.2 +/- 2.93 pmoles of OLA/ml of plasma and 43.7 +/- 0.65. Aftermore » plasma volume expansion for 15 and 30 minutes, plasma OLA was not significantly altered (27.1 +/- 6.64 and 15.3 +/- 2.80, respectively). However, the hematocrit was reduced 13.9% (37.6 +/- 1.34, p < 0.05) and 33.6% (29.0 +/- 1.92, p < 0.01) for 15 and 30 minutes of volume expansion, respectively. After 60 minutes of volume expansion the hematocrit began to recover (33.7 +/- 2.16) although it was still significantly depressed (p < 0.01). At this time point the OLA was increased 248% to 63.4 +/- 22.7 pmoles of OLA/ml of plasma (p < 0.01). At 120 minutes of volume expansion the hematocrit was 38.3 +/- 1.24 and the OLA returned to control values (13.4 +/- 5.17). This data indicates that volume expansion causes an increase in plasma OLA and this increase in activity may contribute to the recovery of hematocrit that is seen with continued volume expansion.« less
Haller, M; Brechtelsbauer, H; Akbulut, C; Fett, W; Briegel, J; Finsterer, U
1995-04-01
To evaluate potential changes in the ratio of whole-body/large-vessel hematocrit (f-cell ratio) during isovolemic hemodilution and to compare the volume effects of 2 different plasma exchange solutions (hydroxyethyl starch 200,000/0.62 6% and human albumin 5%). Prospective, randomized, controlled trial. Operating theater in a university hospital. 24 gynecological patients scheduled for elective surgery. Isovolemic hemodilution was performed using 2 different plasma exchange solutions. Plasma volume was determined using dye dilution technique before and after hemodilution. The volume of withdrawn blood was measured from the change in weight of the blood bags taking into account the specific gravity of blood. The volume of administered plasma exchange solutions exceeded the amount of withdrawn blood by 80 +/- 47 ml (p < 0.001). Plasma volume was 3,067 +/- 327 ml before and 3,517 +/- 458 ml after hemodilution. Using red cell volumes calculated from measured plasma volumes and peripheral hematocrit, a deficit of 249 +/- 133 ml (p < 0.0001) in red cells after hemodilution appeared with the measured withdrawn red cell volumes taken into account. This finding can be explained by a change in the f-cell ratio during isovolemic hemodilution. The volume effect of the exchange solutions was 1.05 for hydroxyethyl starch and 0.95 for albumin. The results demonstrate that a change in the f-cell ratio occurs during isovolemic hemodilution. The estimation of red cell volume or plasma volume changes by using either the hematocrit or plasma or red cell volume determinations together with the hematocrit may lead to erroneous results.
Effect of leg exercise training on vascular volumes during 30 days of 6 deg head-down bed rest
NASA Technical Reports Server (NTRS)
Greenleaf, J. E.; Vernikos, J.; Wade, C. E.; Barnes, P. R.
1992-01-01
In order to investigate the effects of leg exercise training on vascular volumes during 30 d of 6-deg head-down bed rest, plasma and red cell volumes, body density, and water balance were measured in 19 men confined to bed rest (BR). One group had no exercise training (NOE), another near-maximal variable-intensity isotonic exercise (ITE) for 60 min/d, and the third near-maximal intermittent isokinetic exercise (IKE) for 60 min/d. Mean energy costs for the NOE, IKE, and ITE regimens were determined. Body densities within groups and mean urine volumes between groups were unchanged during BR. Changes in red cell volume followed changes in plasma volume. There was close coupling between resting plasma volume and plasma protein and osmotic content. It is argued that the ITE training protocol is better than the IKE protocol for maintaining plasma volume during prolonged exposure to BR.
Miller, Kevin C; Mack, Gary; Knight, Kenneth L
2009-01-01
Health care professionals advocate that athletes who are susceptible to exercise-associated muscle cramps (EAMCs) should moderately increase their fluid and electrolyte intake by drinking sport drinks. Some clinicians have also claimed drinking small volumes of pickle juice effectively relieves acute EAMCs, often alleviating them within 35 seconds. Others fear ingesting pickle juice will enhance dehydration-induced hypertonicity, thereby prolonging dehydration. To determine if ingesting small quantities of pickle juice, a carbohydrate-electrolyte (CHO-e) drink, or water increases plasma electrolytes or other selected plasma variables. Crossover study. Exercise physiology laboratory. Nine euhydrated, healthy men (age = 25 +/- 2 years, height = 179.4 +/- 7.2 cm, mass = 86.3 +/- 15.9 kg) completed the study. Resting blood samples were collected preingestion (-0.5 minutes); immediately postingestion (0 minutes); and at 1, 5, 10, 15, 20, 25, 30, 45, and 60 minutes postingestion of 1 mL/kg body mass of pickle juice, CHO-e drink, or tap water. Plasma sodium concentration, plasma magnesium concentration, plasma calcium concentration, plasma potassium concentration, plasma osmolality, and changes in plasma volume were analyzed. Urine specific gravity, osmolality, and volume were also measured to characterize hydration status. Mean fluid intake was 86.3 +/- 16.7 mL. Plasma sodium concentration, plasma magnesium concentration, plasma calcium concentration, plasma osmolality, and plasma volume did not change during the 60 minutes after ingestion of each fluid (P >or= .05). Water ingestion slightly decreased plasma potassium concentration at 60 minutes (0.21 +/- 0.14 mg/dL [0.21 +/- 0.14 mmol/L]; P
Refaai, Majed A.; Goldstein, Joshua N.; Lee, Martin L.; Durn, Billie L.; Milling, Truman J.; Sarode, Ravi
2015-01-01
BACKGROUND Plasma is commonly used for vitamin K antagonist (VKA) reversal, but observational studies suggest that it is associated with transfusion‐related adverse reactions (e.g., volume overload). However, this issue has not previously been addressed in a randomized controlled trial (RCT). STUDY DESIGN AND METHODS Factors associated with volume overload were examined using data from two Phase IIIb RCTs comparing plasma with four‐factor prothrombin complex concentrate (4F‐PCC, Beriplex/Kcentra, CSL Behring) for urgent VKA reversal. VKA‐treated patients with major bleeding (NCT00708435) or requiring an urgent surgical or invasive procedure (NCT00803101) were randomly assigned (1:1) to receive either plasma or 4F‐PCC, concomitant with vitamin K. Adverse events (AEs) and serious AEs were prospectively captured up to Day 10 and 45, respectively. Volume overload predictors were evaluated on a univariate and multivariate basis. RESULTS A total of 388 patients (4F‐PCC, n = 191; plasma, n = 197) were enrolled. Volume overload occurred in 34 (9%) patients (4F‐PCC, n = 9; plasma, n = 25). In univariate analyses, use of plasma (vs. 4F‐PCC), use of nonstudy plasma and/or platelets, race, history of congestive heart failure (CHF), and history of renal disease were associated with volume overload. In multivariate analyses, use of plasma (vs. 4F‐PCC), history of CHF, and history of renal disease were independent volume overload predictors. In an additional analysis restricted to volume overload events recorded up to Day 7, only use of plasma (vs. 4F‐PCC) was an independent volume overload predictor. CONCLUSIONS After adjusting for other potential risk factors, plasma use was independently associated with a greater risk of volume overload than 4F‐PCC in patients requiring urgent VKA reversal. PMID:26135740
The effect of chronic erythrocytic polycythemia and high altitude upon plasma and blood volumes.
NASA Technical Reports Server (NTRS)
Burton, R. R.; Smith, A. H.
1972-01-01
Comparison of two kinds of physiological chronic erythrocytic polycythemias in order to differentiate the specific effect of erythrocytic polycythemia from the general effects of high altitude upon the plasma volume. The two kinds were produced hormonally in female chickens, at sea level, or by protracted high-altitude exposures. It appears that the vascular system of the body may account for an increase in red blood cell mass either by reduction in plasma volume, or by no change in plasma volume, resulting in differential changes in total blood volumes.
Polidori, David; Rowley, Clarence
2014-07-22
The indocyanine green dilution method is one of the methods available to estimate plasma volume, although some researchers have questioned the accuracy of this method. We developed a new, physiologically based mathematical model of indocyanine green kinetics that more accurately represents indocyanine green kinetics during the first few minutes postinjection than what is assumed when using the traditional mono-exponential back-extrapolation method. The mathematical model is used to develop an optimal back-extrapolation method for estimating plasma volume based on simulated indocyanine green kinetics obtained from the physiological model. Results from a clinical study using the indocyanine green dilution method in 36 subjects with type 2 diabetes indicate that the estimated plasma volumes are considerably lower when using the traditional back-extrapolation method than when using the proposed back-extrapolation method (mean (standard deviation) plasma volume = 26.8 (5.4) mL/kg for the traditional method vs 35.1 (7.0) mL/kg for the proposed method). The results obtained using the proposed method are more consistent with previously reported plasma volume values. Based on the more physiological representation of indocyanine green kinetics and greater consistency with previously reported plasma volume values, the new back-extrapolation method is proposed for use when estimating plasma volume using the indocyanine green dilution method.
Miller, Kevin C.; Mack, Gary; Knight, Kenneth L.
2009-01-01
Abstract Context: Health care professionals advocate that athletes who are susceptible to exercise-associated muscle cramps (EAMCs) should moderately increase their fluid and electrolyte intake by drinking sport drinks. Some clinicians have also claimed drinking small volumes of pickle juice effectively relieves acute EAMCs, often alleviating them within 35 seconds. Others fear ingesting pickle juice will enhance dehydration-induced hypertonicity, thereby prolonging dehydration. Objective: To determine if ingesting small quantities of pickle juice, a carbohydrate-electrolyte (CHO-e) drink, or water increases plasma electrolytes or other selected plasma variables. Design: Crossover study. Setting: Exercise physiology laboratory. Patients or Other Participants: Nine euhydrated, healthy men (age = 25 ± 2 years, height = 179.4 ± 7.2 cm, mass = 86.3 ± 15.9 kg) completed the study. Intervention(s): Resting blood samples were collected preingestion (−0.5 minutes); immediately postingestion (0 minutes); and at 1, 5, 10, 15, 20, 25, 30, 45, and 60 minutes postingestion of 1 mL/kg body mass of pickle juice, CHO-e drink, or tap water. Main Outcome Measure(s): Plasma sodium concentration, plasma magnesium concentration, plasma calcium concentration, plasma potassium concentration, plasma osmolality, and changes in plasma volume were analyzed. Urine specific gravity, osmolality, and volume were also measured to characterize hydration status. Results: Mean fluid intake was 86.3 ± 16.7 mL. Plasma sodium concentration, plasma magnesium concentration, plasma calcium concentration, plasma osmolality, and plasma volume did not change during the 60 minutes after ingestion of each fluid (P ≥ .05). Water ingestion slightly decreased plasma potassium concentration at 60 minutes (0.21 ± 0.14 mg/dL [0.21 ± 0.14 mmol/L]; P ≤ .05). Conclusions: At these volumes, ingestion of pickle juice and CHO-e drink did not cause substantial changes in plasma electrolyte concentrations, plasma osmolality, or plasma volume in rested, euhydrated men. Concern that ingesting these volumes of pickle juice might exacerbate an athlete's risk of dehydration-induced hypertonicity may be unwarranted. If EAMCs are caused by large electrolyte loss due to sweating, these volumes of pickle juice or CHO-e drink are unlikely to restore any deficit incurred by exercise. PMID:19771282
2014-01-01
Background The indocyanine green dilution method is one of the methods available to estimate plasma volume, although some researchers have questioned the accuracy of this method. Methods We developed a new, physiologically based mathematical model of indocyanine green kinetics that more accurately represents indocyanine green kinetics during the first few minutes postinjection than what is assumed when using the traditional mono-exponential back-extrapolation method. The mathematical model is used to develop an optimal back-extrapolation method for estimating plasma volume based on simulated indocyanine green kinetics obtained from the physiological model. Results Results from a clinical study using the indocyanine green dilution method in 36 subjects with type 2 diabetes indicate that the estimated plasma volumes are considerably lower when using the traditional back-extrapolation method than when using the proposed back-extrapolation method (mean (standard deviation) plasma volume = 26.8 (5.4) mL/kg for the traditional method vs 35.1 (7.0) mL/kg for the proposed method). The results obtained using the proposed method are more consistent with previously reported plasma volume values. Conclusions Based on the more physiological representation of indocyanine green kinetics and greater consistency with previously reported plasma volume values, the new back-extrapolation method is proposed for use when estimating plasma volume using the indocyanine green dilution method. PMID:25052018
Fibrinogen Reduction During Selective Plasma Exchange due to Membrane Fouling.
Ohkubo, Atsushi; Okado, Tomokazu; Miyamoto, Satoko; Hashimoto, Yurie; Komori, Shigeto; Yamamoto, Motoki; Maeda, Takuma; Itagaki, Ayako; Yamamoto, Hiroko; Seshima, Hiroshi; Kurashima, Naoki; Iimori, Soichiro; Naito, Shotaro; Sohara, Eisei; Uchida, Shinichi; Rai, Tatemitsu
2017-06-01
Fibrinogen is substantially reduced by most plasmapheresis modalities but retained in selective plasma exchange using Evacure EC-4A10 (EC-4A). Although EC-4A's fibrinogen sieving coefficient is 0, a session of selective plasma exchange reduced fibrinogen by approximately 19%. Here, we investigated sieving coefficient in five patients. When the mean processed plasma volume was 1.15 × plasma volume, the mean reduction of fibrinogen during selective plasma exchange was approximately 15%. Fibrinogen sieving coefficient was 0 when the processed plasma volume was 1.0 L, increasing to 0.07 when the processed plasma volume was 3.0 L, with a mean of 0.03 during selective plasma exchange. When fibrinogen sieving coefficient was 0, selective plasma exchange reduced fibrinogen by approximately 10%. Scanning electron microscopy images revealed internal fouling of EC-4A's hollow fiber membrane by substances such as fibrinogen fibrils. Thus, fibrinogen reduction by selective plasma exchange may be predominantly caused by membrane fouling rather than filtration. © 2017 International Society for Apheresis, Japanese Society for Apheresis, and Japanese Society for Dialysis Therapy.
Effect Of Leg Exercise On Vascular Volumes During Bed Rest
NASA Technical Reports Server (NTRS)
Greenleaf, J. E.; Vernikos, J.; Wade, C. E.; Barnes, P. R.
1993-01-01
Report describes experiments on effects of no-exercise regimen and of two leg-exercise regimens on volumes of plasma, volumes of red blood cells, densities of bodies, and water balances of 19 men (32 to 42 years old) confined to minus 6 degrees-head-down bed rest for 30 days. Purpose of study to determine whether either or both exercise regimens maintain plasma volume and to relate levels of hypovolemia to body fluid balances. Results showed during bed rest, plasma volume maintained in isotomic group but not in other two groups, and no significant differences in body densities, body weights, or water balances among three groups. Concludes isotonic-exercise regimen better than isokinetic-exercise regimen for maintaining plasma volume during prolonged exposure to bed rest.
The use of biomarkers to describe plasma-, red cell-, and blood volume from a simple blood test.
Lobigs, Louisa Margit; Sottas, Pierre-Edouard; Bourdon, Pitre Collier; Nikolovski, Zoran; El-Gingo, Mohamed; Varamenti, Evdokia; Peeling, Peter; Dawson, Brian; Schumacher, Yorck Olaf
2017-01-01
Plasma volume and red cell mass are key health markers used to monitor numerous disease states, such as heart failure, kidney disease, or sepsis. Nevertheless, there is currently no practically applicable method to easily measure absolute plasma or red cell volumes in a clinical setting. Here, a novel marker for plasma volume and red cell mass was developed through analysis of the observed variability caused by plasma volume shifts in common biochemical measures, selected based on their propensity to present with low variations over time. Once a month for 6 months, serum and whole blood samples were collected from 33 active males. Concurrently, the CO-rebreathing method was applied to determine target levels of hemoglobin mass (HbM) and blood volumes. The variability of 18 common chemistry markers and 27 Full Blood Count variables was investigated and matched to the observed plasma volume variation. After the removal of between-subject variations using a Bayesian model, multivariate analysis identified two sets of 8 and 15 biomarkers explaining 68% and 69% of plasma volume variance, respectively. The final multiparametric model contains a weighting function to allow for isolated abnormalities in single biomarkers. This proof-of-concept investigation describes a novel approach to estimate absolute vascular volumes, with a simple blood test. Despite the physiological instability of critically ill patients, it is hypothesized the model, with its multiparametric approach and weighting function, maintains the capacity to describe vascular volumes. This model has potential to transform volume management in clinical settings. Am. J. Hematol. 92:62-67, 2017. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.
Low current plasmatron fuel converter having enlarged volume discharges
Rabinovich, Alexander; Alexeev, Nikolai; Bromberg, Leslie; Cohn, Daniel R.; Samokhin, Andrei
2005-04-19
A novel apparatus and method is disclosed for a plasmatron fuel converter (""plasmatron"") that efficiently uses electrical energy to produce hydrogen rich gas. The volume and shape of the plasma discharge is controlled by a fluid flow established in a plasma discharge volume. A plasmatron according to this invention produces a substantially large effective plasma discharge volume allowing for substantially greater volumetric efficiency in the initiation of chemical reactions within a volume of bulk fluid reactant flowing through the plasmatron.
Low current plasmatron fuel converter having enlarged volume discharges
Rabinovich, Alexander [Swampscott, MA; Alexeev, Nikolai [Moscow, RU; Bromberg, Leslie [Sharon, MA; Cohn, Daniel R [Chestnut Hill, MA; Samokhin, Andrei [Moscow, RU
2009-10-06
A novel apparatus and method is disclosed for a plasmatron fuel converter ("plasmatron") that efficiently uses electrical energy to produce hydrogen rich gas. The volume and shape of the plasma discharge is controlled by a fluid flow established in a plasma discharge volume. A plasmatron according to this invention produces a substantially large effective plasma discharge volume allowing for substantially greater volumetric efficiency in the initiation of chemical reactions within a volume of bulk fluid reactant flowing through the plasmatron.
Exercise training hypotension - Implications for plasma volume, renin, and vasopressin
NASA Technical Reports Server (NTRS)
Greenleaf, J. E.; Sciaraffa, D.; Shvartz, E.; Keil, L. C.; Brock, P. J.
1981-01-01
The relation of changes in plasma volume, plasma renin activity and arginine vasopressin to changes in resting blood pressure during exercise training is investigated. Resting supine, sitting, and standing systolic and fifth-phase diastolic blood pressures were measured in ten men before and after an eight-day training period on a cycle ergometer in either a hot (39.8 C) or cool (23.8 C) environment, and compared with plasma volume, renin and vasopressin levels, heart rates, maximal oxygen uptakes, rectal temperatures and sweat rates. Following acclimatization, resting supine and sitting diastolic pressures are observed to decrease by 6 and 9 mm Hg, respectively, while no significant changes are found in the diastolic pressures of the control group or the systolic pressures of either group. Resting plasma volume is found to increase by 12.2% in the controls and by 17.6% after acclimatization following the exercise training. Results suggest that the resting hypotension produced is not attributable to changes in resting plasma volume, renin or vasopressin, although heat acclimatization, which leads to large decreases in plasma volume and increases in vasopressin and renin activity, may be useful in the treatment of hypertension.
Clinical Aspects of the Control of Plasma Volume at Microgravity and During Return to One Gravity
NASA Technical Reports Server (NTRS)
Convertino, Victor A.
1995-01-01
Plasma volume is reduced by 10%-20% within 24 to 48 h of exposure to simulated or actual microgravity. The clinical importance of microgravity-induced hypovolemia is manifested by its relationship with orthostatic intolerance and reduced VO2max after return to one gravity (1G). Since there is no evidence to suggest plasma volume reduction during microgravity is associated with thirst or renal dysfunctions, a diuresis induced by an immediate blood volume shift to the central circulation appears responsible for microgravity-induced hypovolemia. Since most astronauts choose to restrict their fluid intake before a space mission, absence of increased urine output during actual spaceflight may be explained by low central venous pressure (CVP) which accompanies dehydration. Compelling evidence suggests that prolonged reduction in CVP during exposure to microgravity reflects a 'resetting' to a lower operating point which acts to limit plasma volume expansion during attempts to increase fluid intake. In groudbase and spaceflight experiments, successful restoration and maintenance of plasma volume prior to returning to an upright posture may depend upon development of treatments that can return CVP to its baseline 10 operating point. Fluid-loading and LBNP have not proved completely effective in restoring plasma volume, suggesting that they may not provide the stimulus to elevate the CVP operating point. On the other, exercise, which can chronically increase CVP, has been effective in expanding plasma volume when combined with adequate dietary intake of fluid and electrolytes. The success of designing experiments to understand the physiological mechanisms of and development of effective countermeasures for the control of plasma volume in microgravity and during return to one gravity will depend upon testing that can be conducted under standardized controlled baseline condi
Red cell volume with changes in plasma osmolarity during maximal exercise.
NASA Technical Reports Server (NTRS)
Van Beaumont, W.
1973-01-01
The volume of the red cell in vivo was measured during acute changes in plasma osmolarity evoked through short (6 to 8 min) maximal exercise in six male volunteer subjects. Simultaneous measurements of mean corpuscular red cell volume (MCV), hematocrit, blood hemoglobin, mean corpuscular hemoglobin concentration (MCHC), and plasma osmolarity showed that there was no change in the MCV or MCHC with a concomitant rise of nearly 6% in plasma osmolarity. Apparently, in vivo, the volume of the red cell in exercising healthy human subjects does not change measurably, in spite of significant changes in osmotic pressure of the surrounding medium. Consequently, it is not justified to correct postexercise hematocrit measurements for changes in plasma osmolarity.
The Role of Blood Osmolality and Volume in Regulating Vasopressin Secretion in the Rat
Dunn, Fredrick L.; Brennan, Thomas J.; Nelson, Averial E.; Robertson, Gary L.
1973-01-01
A sensitive and specific radioimmunoassay for plasma arginine vasopressin (AVP) has been used to study the effects of blood osmolality and volume in regulating AVP secretion in unanesthetized rats. Under basal conditions, plasma AVP and osmolality were relatively constant, averaging 2.3±0.9 (SD) pg/ml and 294±1.4 mosmol/kg, respectively. Fluid restriction, which increased osmolality and decreased volume, resulted in a progressive rise in plasma AVP to about 10 times basal levels after 96 h. A 2-3-fold increase in plasma AVP occurred as early as 12 h, when osmolality and volume had each changed by less than 2%. Intraperitoneal injections of hypertonic saline, which had no effect on blood volume, also produced a rise in plasma AVP that was linearly correlated with the rise in osmolality (r > 0.9) and quantitatively similar to that found during fluid restriction (plasma AVP increased 2-4-fold with each 1% increase in osmolality). Intraperitoneal injection of polyethylene glycol, which decreased blood volume without altering osmolality, also increased plasma AVP but this response followed an exponential pattern and did not become significant until volume had decreased by 8% or more. At these levels of hypovolemia, the osmoregulatory system continued to function but showed a lower threshold and increase sensitivity to osmotic stimulation. We conclude that AVP secretion is regulated principally by blood osmolality but that the responsiveness of this mechanism may be significantly altered by modest changes in blood volume. PMID:4750450
Plasma volume, osmolality, vasopressin, and renin activity during graded exercise in man
NASA Technical Reports Server (NTRS)
Convertino, V. A.; Keil, L. C.; Bernauer, E. M.; Greenleaf, J. E.
1981-01-01
The influence of work intensity on plasma volume, osmolality, vasopressin and renin activity and the interrelationships between these responses are investigated. Plasma volume, renin activity and osmotic, sodium and arginine vasopressin concentrations were measured in venous blood samples taken from 15 healthy male subjects before and after six minutes of bicycle ergometer exercise at 100, 175 and 225 W. Plasma volume is found to decrease significantly with increasing work intensity, while increases in Na(+) concentration, osmolality and vasopressin are only observed to be significant when the work intensity exceeds 40% maximal aerobic capacity and plasma resin activity increased linearly at all work levels. In addition, significant correlations are observed between plasma volume and osmolality and sodium changes, and between vasopressin and osmolality and sodium content changes. Data thus support the hypotheses that (1) vasopressin may be the primary controlling endocrine for fluid and electrolyte levels following exercise; (2) an exercise intensity greater than 40% maximal aerobic capacity is required to stimulate vasopressin release through changes in plasma osmolality; and (3) the stimulation of the renin-angiotensin system is a more general stress response.
Plasma clots gelled by different amounts of calcium for stem cell delivery.
Gessmann, Jan; Seybold, Dominik; Peter, Elvira; Schildhauer, Thomas Armin; Köller, Manfred
2013-01-01
Freshly prepared autologous plasma clots may serve as a carrier matrix for expanded multipotent mesenchymal stromal cells (MSCs) or bone marrow cells. By varying the calcium concentration, plasma clots with different properties can be produced. The purpose of this in vitro study was to determine the optimal calcium concentrations for the clotting process, intra-clot cell viability, and clot lysis. Different plasma clots were prepared by adding an equal volume of RPMI1640 (with or without MSCs) to citrate plasma (either containing platelets or platelet-free). Clotting was initiated by the addition of CaCl(2) (10 g/100 ml H(2)O, 10 % solution). The final concentration of CaCl(2) ranged from 1 to 10 % by volume of plasma. Viability and distribution of the MSCs were analysed by calcein-AM/propidium iodide staining. MSC-embedded plasma clots were dissolved with trypsin (0.25 %), and recovered cells were further incubated for 1 week under cell culture conditions. The viability of MSCs embedded in clots formed by the addition of 1-8 % by volume CaCl2 was not affected by incubation of up to 1 week. In contrast, clots produced by higher volumes of CaCl(2) solutions (9-10 % by volume of plasma) showed decreased numbers of viable cells. Intra-clot cell proliferation was highest in clots produced by addition of 5 % CaCl(2) by plasma volume. Osteocalcin release was not influenced in platelet-free plasma but decreased in platelet-containing plasma. Morphological analysis of stained recovered MSCs revealed that lysis of the plasma clot did not affect cell morphology or subsequent spontaneous proliferation. Clot formation and clot stability can be controlled by changing the concentration of CaCl(2) added to plasma. The addition of 5 % CaCl(2) produced a plasma clot with optimal results for stem cell delivery.
Effect of leg exercise training on vascular volumes during 30 days of 6 degrees head-down bed rest
NASA Technical Reports Server (NTRS)
Greenleaf, J. E.; Vernikos, J.; Wade, C. E.; Barnes, P. R.
1992-01-01
Plasma and red cell volumes, body density, and water balance were measured in 19 men (32-42 yr) confined to bed rest (BR). One group (n = 5) had no exercise training (NOE), another near-maximal variable-intensity isotonic exercise for 60 min/day (ITE; n = 7), and the third near-maximal intermittent isokinetic exercise for 60 min/day (IKE; n = 7). Caloric intake was 2,678-2,840 kcal/day; mean body weight (n = 19) decreased by 0.58 +/- 0.35 (SE) kg during BR due to a negative fluid balance (diuresis) on day 1. Mean energy costs for the NOE, and IKE, and ITE regimens were 83 (3.6 +/- 0.2 ml O2.min-1.kg-1), 214 (8.9 +/- 0.5 ml.min-1.kg-1), and 446 kcal/h (18.8 +/- 1.6 ml.min-1.kg-1), respectively. Body densities within groups and mean urine volumes (1,752-1,846 ml/day) between groups were unchanged during BR. Resting changes in plasma volume (ml/kg) after BR were -1.5 +/- 2.3% (NS) in ITE, -14.7 +/- 2.8% (P less than 0.05) in NOE, and -16.8 +/- 2.9% (P less than 0.05) in IKE, and mean water balances during BR were +295, -106, and +169 ml/24 h, respectively. Changes in red cell volume followed changes in plasma volume. The significant chronic decreases in plasma volume in the IKE and NOE groups and its maintenance in the ITE group could not be accounted for by water balance or by responses of the plasma osmotic, protein, vasopressin, or aldosterone concentrations or plasma renin activity. There was close coupling between resting plasma volume and plasma protein and osmotic content.(ABSTRACT TRUNCATED AT 250 WORDS).
Effect of hydration on plasma volume and endocrine responses to water immersion
NASA Technical Reports Server (NTRS)
Harrison, M. H.; Keil, L. C.; Wade, C. A.; Silver, J. E.; Geelen, G.
1986-01-01
The effect of hydration status on early endocrine responses and on osmotic and intravascular volume changes during immersion was determined in humans undergoing successive periods of dehydration, immersion, rehydration, and immersion. Immersion caused an isotonic expansion of plasma volume, as well as suppression of plasma renin activity and aldosterone, which all occurred independently of hydration status. On the other hand, the concentration of plasma vasopressin (PVP) was found to decrease during dehydrated immersion, but not during rehydrated immersion. It is concluded that plasma tonicity is not a factor influencing PVP suppression during water immersion.
Measurement of Human Blood and Plasma Volumes
NASA Technical Reports Server (NTRS)
Greenleaf, J. E.; Szalkay, H. G. H.
1987-01-01
Report reviews techniques for measuring blood-plasma volume in humans. Common technique of using radioactive iodine isotope to label plasma albumin involves unwarranted risks from low-level radiation. Report emphasizes techniques using Evans-blue-dye (T-1824) labeling of albumin, hematocrit or hemoglobin/hematocrit measurements, or blood densitometry. In Evans-blue-dye technique, plasma volume determined from decrease in dye concentration occurring after small amount of dye solution injected into circulatory system. Subjection of Evans blue dye to test for carcinogenicity gave negative results.
Clinical aspects of the control of plasma volume at microgravity and during return to one gravity
NASA Technical Reports Server (NTRS)
Convertino, V. A.
1996-01-01
Plasma volume is reduced by 10-20% within 24-48 h of exposure to simulated or actual microgravity. The clinical importance of microgravity induced hypovolemia is manifested by its relationship with orthostatic intolerance and reduced maximal oxygen uptake (VO2max) after return to one gravity (1G). Since there is no evidence to suggest that plasma volume reduction during microgravity is associated with thirst or renal dysfunctions, a diuresis induced by an immediate blood volume shift to the central circulation appears responsible for microgravity-induced hypovolemia. Since most astronauts choose to restrict their fluid intake before a space mission, absence of increased urine output during actual space flight may be explained by low central venous pressure (CVP) which accompanies dehydration. Compelling evidence suggests that prolonged reduction in CVP during exposure to microgravity reflects a "resetting" to a lower operating point, which acts to limit plasma volume expansion during attempts to increase fluid intake. In ground based and space flight experiments, successful restoration and maintenance of plasma volume prior to returning to an upright posture may depend upon development of treatments that can return CVP to its baseline IG operating point. Fluid-loading and lower body negative pressure (LBNP) have not proved completely effective in restoring plasma volume, suggesting that they may not provide the stimulus to elevate the CVP operating point. On the other hand, exercise, which can chronically increase CVP, has been effective in expanding plasma volume when combined with adequate dietary intake of fluid and electrolytes. The success of designing experiments to understand the physiological mechanisms of and development of effective counter measures for the control of plasma volume in microgravity and during return to IG will depend upon testing that can be conducted under standardized controlled baseline conditions during both ground-based and space flight investigations.
NASA Technical Reports Server (NTRS)
Convertino, V. A.
1998-01-01
To test the hypothesis that the magnitude of reduction in plasma volume and work capacity following exposure to simulated microgravity is dependent on the initial level of aerobic fitness, peak oxygen uptake (VO2peak) was measured in a group of physically fit subjects and compared with VO2peak in a group of relatively unfit subjects before and after 10 days of continuous 6 degrees head-down tilt (HDT). Ten fit subjects (40 +/- 2 year) with mean +/- SE VO2peak = 48.9 +/- 1.7 mL kg-1 min-1 were matched for age, height, and lean body weight with 10 unfit subjects (VO2peak = 37.7 +/- 1.6 mL kg-1 min-1). Before and after HDT, plasma, blood, and red cell volumes and body composition were measured and all subjects underwent a graded supine cycle ergometer test to determine VO2peak period needed. Reduced VO2peak in fit subjects (-16.2%) was greater than that of unfit subjects (-6.1%). Similarly, reductions in plasma (-18.3%) and blood volumes (-16.0%) in fit subjects were larger than those of unfit subjects (blood volume = -5.6%; plasma volume = -6.6%). Reduced plasma volume was associated with greater negative body fluid balance during the initial 24 h of HDT in the fit group (912 +/- 154 mL) compared with unfit subjects (453 +/- 200 mL). The percentage change for VO2peak correlated with percentage change in plasma volume (r = +0.79). Following exposure to simulated microgravity, fit subjects demonstrated larger reductions in VO2peak than unfit subjects which was associated with larger reductions in plasma and blood volume. These data suggest that the magnitude of physical deconditioning induced by exposure to microgravity without intervention of countermeasures was influenced by the initial fitness of the subjects.
Bagrov, A Y; Fedorova, O V; Dmitrieva, R I; French, A W; Anderson, D E
1996-02-01
This study investigated effects of acute plasma volume expansion on plasma levels and urinary output of two endogenous Na,K-ATPase inhibitors, marinobufagenin-like and ouabain-like immunoreactive substances. Plasma volume was expanded for 3 h via intravenous saline infusion in three groups of anesthetized dogs--nontreated (n = 5); pretreated with rabbit antidigoxin (n = 5); and pretreated with rabbit antimouse (control) antibody (n = 4). Plasma marinobufagenin-like immunoreactivity increased to 11.87 +/- 3.16 nmol.l-1 (vs. 0.30 +/- 0.16 nmol.l-1) within 10 min of volume expansion, in parallel with a 15% increase in LVdP/dt, then decreased to 2.21 +/- 0.59 nmol.l-1, and in 90 min increased to 11.8 +/- 2.8 nmol.l-1, in parallel with the maximal natriuretic response. Plasma concentrations of ouabain-like immunoreactive material were increased after 90 min of saline infusion (0.019 +/- 0.004 nmol.l-1 vs. 0.139 +/- 0.056 nmol.l-1). Pretreatment of the animals with antidigoxin antibody blocked the positive inotropic and reduced natriuretic response to volume expansion, and decreased the urinary release of marinobufagenin-like, but not ouabain-like, material. These results show the presence of marinobufagenin-like immunoreactive substance in dog plasma and suggest that mammalian EDLF may have a bufodienolide nature. Endogenous marinobufagenin-like immunoreactive substance, which is likely to cross-react with antidigoxin antibody, is involved in the natriuretic and positive inotropic responses to plasma volume expansion.
Gingerich, W.H.; Pityer, R.A.; Rach, J.J.
1987-01-01
1. Total blood volume and relative blood volumes in selected tissues were determined in non-anesthetized, confined rainbow trout by using 51Cr-labelled trout erythrocytes as a vascular space marker.2. Mean total blood volume was estimated to be 4.09 ± 0.55 ml/100 g, or about 75% of that estimated with the commonly used plasma space marker Evans blue dye.3. Relative tissue blood volumes were greatest in highly perfused tissues such as kidney, gills, brain and liver and least in mosaic muscle.4. Estimates of tissue vascular spaces, made using radiolabelled erythrocytes, were only 25–50% of those based on plasma space markers.5. The consistently smaller vascular volumes obtained with labelled erythrocytes could be explained by assuming that commonly used plasma space markers diffuse from the vascular compartment.
Concerning neutral flux shielding in the U-3M torsatron
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dreval, N. B., E-mail: mdreval@kipt.kharkov.ua
2015-03-15
The volume of the torsatron U-3M vacuum chamber is about 70 m{sup 3}, whereas the plasma volume is about 0.3 m{sup 3}. The large buffer volume of the chamber serves as a source of a substantial neutral flux into the U-3M plasma. A fraction of this flux falls onto the torsatron helical coils located in front of the plasma, due to which the dynamics of neutral influx into the plasma modifies. The shielding of the molecular flux from the buffer volume into the plasma is estimated using numerical calculations. Only about 10% of the incident flux reaches the plasma volume.more » Estimates show that about 20% of atoms escape beyond the helical coils without colliding with them. Under these conditions, the helical coils substantially affect the neutral flux. A discharge regime with a hot low-density plasma produced by a frame antenna is considered. The spatial distribution of the molecular density produced in this regime by the molecular flux from the chamber buffer volume after it has passed between the helical coils is calculated. The contributions of the fluxes emerging from the side and inner surfaces of the helical coils are considered. The calculations show that the shape of the spatial distribution of the molecular density differs substantially from the shape of the magnetic surfaces.« less
Hormonal and electrolyte responses to acute isohemic volume expansion in unanesthetized rats
NASA Technical Reports Server (NTRS)
Chenault, V. M.; Morris, M.; Lynch, C. D.; Maultsby, S. J.; Hutchins, P. M.
1993-01-01
This study was undertaken to explore the time course of the metabolic response to isohemic blood volume expansion (30%) in normotensive, unanesthetized Sprague-Dawley rats. Whole blood, drawn from a femoral artery catheter of conscious donor rats, was infused into the jugular vein of recipient rats. Blood samples were drawn from a carotid artery of recipient rats at time points beginning immediately post-volume expansion (IPVE) up through 5 days post-volume expansion (PVE). To characterize the attendant compensatory mechanisms, the plasma concentrations of electrolytes and fluid regulatory hormones were determined. Hematocrit began to raise IPVE and was significantly elevated above control IPVE 20, 30, 40, 60, and 90 min, and 2, 4, 6, 8, 12, and 24 hr PVE. Consistent with our current understanding of the hormonal response to excess volume, atrial natriuretic factor was significantly increased above the prevolume expansion (control) values 0-30 min PVE. Surprisingly, plasma aldosterone levels were significantly increased above control at 20 and 30 min and 6 hr PVE, whereas plasma renin activity was significantly decreased 30-40 min PVE. Plasma sodium was not changed from control values except for a significant increase at 6 hr post-volume expansion. Plasma potassium, osmolality, and arginine vasopressin levels were not altered by the volume expansion. These studies delineate the physiologic time scheme operative in the regulation of fluid volume during acute ischemic volume expansion.
Post-traumatic changes in, and effect of colloid osmotic pressure on the distribution of body water.
Böck, J C; Barker, B C; Clinton, A G; Wilson, M B; Lewis, F R
1989-09-01
The aim of this study was to define the post-traumatic changes in body fluid compartments and to evaluate the effect of plasma colloid osmotic pressure (COP) on the partitioning of body fluid between these compartments. Forty-two measurements of plasma volume (green dye), extracellular volume (bromine), and total body water (deuterium) were done in ten traumatized patients (mean Injury Severity Score, ISS, = 34) and 23 similar control studies were done in eight healthy volunteers who were in stable fluid balance. Interstitial volume, intracellular volume, and blood volume were calculated from measured fluid spaces and hematocrit; COP was directly measured. Studies in volunteers on consecutive days indicated good reproducibility, with coefficients of variation equal to 3.5% for COP, 6.3% for plasma volume, 4.5% for extracellular volume, and 4.9% for total body water. COP values extended over the entire range seen clinically, from 10 to 30 mmHg. Interstitial volume was increased by 55% in patients, but intracellular volume was decreased by 10%. We conclude (1) that posttraumatic peripheral edema resulting from hemodilution is located in the interstitial compartment, with no intracellular space expansion; and (2) that interstitial volume, but not intracellular volume, is closely related to plasma COP.
Nguyen, T B; Cron, G O; Mercier, J F; Foottit, C; Torres, C H; Chakraborty, S; Woulfe, J; Jansen, G H; Caudrelier, J M; Sinclair, J; Hogan, M J; Thornhill, R E; Cameron, I G
2015-01-01
The prognostic value of dynamic contrast-enhanced MR imaging-derived plasma volume obtained in tumor and the contrast transfer coefficient has not been well-established in patients with gliomas. We determined whether plasma volume and contrast transfer coefficient in tumor correlated with survival in patients with gliomas in addition to other factors such as age, type of surgery, preoperative Karnofsky score, contrast enhancement, and histopathologic grade. This prospective study included 46 patients with a new pathologically confirmed diagnosis of glioma. The contrast transfer coefficient and plasma volume obtained in tumor maps were calculated directly from the signal-intensity curve without T1 measurements, and values were obtained from multiple small ROIs placed within tumors. Survival curve analysis was performed by dichotomizing patients into groups of high and low contrast transfer coefficient and plasma volume. Univariate analysis was performed by using dynamic contrast-enhanced parameters and clinical factors. Factors that were significant on univariate analysis were entered into multivariate analysis. For all patients with gliomas, survival was worse for groups of patients with high contrast transfer coefficient and plasma volume obtained in tumor (P < .05). In subgroups of high- and low-grade gliomas, survival was worse for groups of patients with high contrast transfer coefficient and plasma volume obtained in tumor (P < .05). Univariate analysis showed that factors associated with lower survival were age older than 50 years, low Karnofsky score, biopsy-only versus resection, marked contrast enhancement versus no/mild enhancement, high contrast transfer coefficient, and high plasma volume obtained in tumor (P < .05). In multivariate analysis, a low Karnofsky score, biopsy versus resection in combination with marked contrast enhancement, and a high contrast transfer coefficient were associated with lower survival rates (P < .05). In patients with glioma, those with a high contrast transfer coefficient have lower survival than those with low parameters. © 2015 by American Journal of Neuroradiology.
Atmospheric Gaseous Plasma with Large Dimensions
NASA Astrophysics Data System (ADS)
Korenev, Sergey
2012-10-01
The forming of atmospheric plasma with large dimensions using electrical discharge typically uses the Dielectric Barrier Discharge (DBD). The study of atmospheric DBD was shown some problems related to homogeneous volume plasma. The volume of this plasma determines by cross section and gas gap between electrode and dielectric. The using of electron beam for volume ionization of air molecules by CW relativistic electron beams was shown the high efficiency of this process [1, 2]. The main advantage of this approach consists in the ionization of gas molecules by electrons in longitudinal direction determines by their kinetic energy. A novel method for forming of atmospheric homogeneous plasma with large volume dimensions using ionization of gas molecules by pulsed non-relativistic electron beams is presented in the paper. The results of computer modeling for delivered doses of electron beams in gases and ionization are discussed. The structure of experimental bench with plasma diagnostics is considered. The preliminary results of forming atmospheric plasma with ionization gas molecules by pulsed nanosecond non-relativistic electron beam are given. The analysis of potential applications for atmospheric volume plasma is presented. Reference: [1] S. Korenev. ``The ionization of air by scanning relativistic high power CW electron beam,'' 2002 IEEE International Conference on Plasma Science. May 2002, Alberta, Canada. [2] S. Korenev, I. Korenev. ``The propagation of high power CW scanning electron beam in air.'' BEAMS 2002: 14th International Conference on High-Power Particle Beams, Albuquerque, New Mexico (USA), June 2002, AIP Conference Proceedings Vol. 650(1), pp. 373-376. December 17.
21 CFR 606.122 - Instruction circular.
Code of Federal Regulations, 2010 CFR
2010-04-01
... instruction circular shall contain: (1) Instructions to administer a suitable plasma volume expander if Red... circular shall contain: (1) The approximate volume of plasma from which a sample unit of Platelets is... entering the container. (m) For Plasma, the instruction circular shall contain: (1) A warning against...
21 CFR 606.122 - Instruction circular.
Code of Federal Regulations, 2011 CFR
2011-04-01
... instruction circular shall contain: (1) Instructions to administer a suitable plasma volume expander if Red... circular shall contain: (1) The approximate volume of plasma from which a sample unit of Platelets is... entering the container. (m) For Plasma, the instruction circular shall contain: (1) A warning against...
Coupling of RF antennas to large volume helicon plasma
NASA Astrophysics Data System (ADS)
Chang, Lei; Hu, Xinyue; Gao, Lei; Chen, Wei; Wu, Xianming; Sun, Xinfeng; Hu, Ning; Huang, Chongxiang
2018-04-01
Large volume helicon plasma sources are of particular interest for large scale semiconductor processing, high power plasma propulsion and recently plasma-material interaction under fusion conditions. This work is devoted to studying the coupling of four typical RF antennas to helicon plasma with infinite length and diameter of 0.5 m, and exploring its frequency dependence in the range of 13.56-70 MHz for coupling optimization. It is found that loop antenna is more efficient than half helix, Boswell and Nagoya III antennas for power absorption; radially parabolic density profile overwhelms Gaussian density profile in terms of antenna coupling for low-density plasma, but the superiority reverses for high-density plasma. Increasing the driving frequency results in power absorption more near plasma edge, but the overall power absorption increases with frequency. Perpendicular stream plots of wave magnetic field, wave electric field and perturbed current are also presented. This work can serve as an important reference for the experimental design of large volume helicon plasma source with high RF power.
NASA Astrophysics Data System (ADS)
Dent, Paul; Deng, Bin; Goodisman, Jerry; Peterson, Charles M.; Narsipur, Sriram; Chaiken, J.
2016-04-01
A new device incorporating a new algorithm and measurement process allows simultaneous noninvasive in vivo monitoring of intravascular plasma volume and red blood cell volume. The purely optical technique involves probing fingertip skin with near infrared laser light and collecting the wavelength shifted light, that is, the inelastic emission (IE) which includes the unresolved Raman and fluorescence, and the un-shifted emission, that is, the elastic emission (EE) which includes both the Rayleigh and Mie scattered light. Our excitation and detection geometry is designed so that from these two simultaneous measurements we can calculate two parameters within the single scattering regime using radiation transfer theory, the intravascular plasma volume fraction and the red blood cell volume fraction. Previously calibrated against a gold standard FDA approved device, 2 hour monitoring sessions on three separate occasions over a three week span for a specific, motionless, and mostly sleeping individual produced 3 records containing a total of 5706 paired measurements of hematocrit and plasma volume. The average over the three runs, relative to the initial plasma volume taken as 100%, of the plasma volume±1σ was 97.56+/-0.55 or 0.56%.For the same three runs, the average relative hematocrit (Hct), referenced to an assumed initial value of 28.35 was 29.37+/-0.12 or stable to +/-0.4%.We observe local deterministic circulation effects apparently associated with the pressure applied by the finger probe as well as longer timescale behavior due to normal ebb and flow of internal fluids due to posture changes and tilt table induced gravity gradients.
Choice of the replacement fluid during large volume plasma-exchange.
Nydegger, U E
1983-01-01
The replacement fluid used during therapeutic large volume plasma-exchange can be seen as an important factor influencing the result of such treatment. The choice includes fluids such as electrolyte solutions, gelatin, hydroxyethyl-starch, albumin and fresh frozen plasma. By evaluating the pathophysiology of the underlying disease, it is possible to choose between merely replacing the removed volume by non-protein fluids or rather to introduce plasma protein components into the patient's circulation by substituting with purified or enriched proteins such as albumin, clotting factors, antithrombin III or fresh frozen plasma. This paper analyzes the rationale for the choice of the appropriate replacement fluid taking into account pathophysiologic, pharmacologic and logistic criteria.
Volume of Plasma Expansion and Functional Outcomes in Stroke.
Miller, Joseph B; Lewandowski, Christopher; Wira, Charles R; Taylor, Andrew; Burmeister, Charlotte; Welch, Robert
2017-04-01
Plasma expansion in acute ischemic stroke has potential to improve cerebral perfusion, but the long-term effects on functional outcome are mixed in prior trials. The goal of this study was to evaluate how the magnitude of plasma expansion affects neurological recovery in acute stroke. This was a secondary analysis of data from the Albumin in Acute Stroke Part 2 trial investigating the relationship between the magnitude of overall intravenous volume infusion (crystalloid and colloid) to clinical outcome. The data were inclusive of 841 patients with a mean age of 64 years and a median National Institutes of Health Stroke Scale (NIHSS) of 11. In a multivariable-adjusted logistic regression model, this analysis tested the volume of plasma expansion over the first 48 h of hospitalization as a predictor of favorable outcome, defined as either a modified Rankin Scale score of 0 or 1 or a NIHSS score of 0 or 1 at 90 days. This model included all study patients, irrespective of albumin or isotonic saline treatment. Patients that received higher volumes of plasma expansion more frequently had large vessel ischemic stroke and higher NIHSS scores. The multivariable-adjusted model revealed that there was decreased odds of a favorable outcome for every 250 ml additional volume plasma expansion over the first 48 h (OR 0.91, 95 % CI, 0.88-0.94). The present study demonstrates an association between greater volume of plasma expansion and worse neurological recovery.
A model for plasma volume changes during short duration spaceflight
NASA Technical Reports Server (NTRS)
Davis, John E.
1989-01-01
It is well established that plasma volume decreases during spaceflight and simulated weightlessness (bedrest). The decrement in plasma volume is thought to contribute to the orthostatic intolerance that has been observed in some crew members following spaceflight. To date, no studies have evaluated the effectiveness of fluid countermeasures of varying osmolality in the restoration of plasma volume and orthostatic tolerance in a controlled study. The overall objectives of this project were to: (1) provide a model that would rapidly and safely produce a fluid loss comparable to that which occurs during short duration spaceflight; and (2) design a study that would determine the optimal drink solution to restore orthostatic tolerance and describe the mechanism(s) whereby orthostatic tolerance is restored. In summary, Lasix can be used as a way of simulating the plasma volume changes that occur during short duration spaceflight. The total loss of plasma is comparable to spaceflight. Lasix is fast acting, and has relatively few side effects. The present design for evaluating the optimal fluid countermeasures will have important implications in restoring orthostatic tolerance and function in the latter stages of spaceflight when it is essential for safe operation of the spacecraft.
Gingerich, W.H.; Pityer, R.A.
1989-01-01
Total, packed cell and, plasma volume estimates were made for the whole body and selected tissues of rainbow trout by the simultaneous injection of radiolabelled trout erythrocyte (51Cr-RBC) and radioiodinated bovine serum albumin (125I-BSA) tracers. Blood volumes were estimated with both markers separately by the tracer-hematocrit method and as the combination of the 51Cr-RBC packed cell and 125I-BSA plasma volumes. Mean whole body blood volume was significantly less when calculated from the 51Cr-RBC tracer data (3.52±0.78 ml/100 g; ±SD) than when calculated with the 125I-BSA tracer (5.06±0.86 ml/100 g) or as the sum of the two volumes combined (4.49±0.60 ml/100 g). The whole body hematocrit (28±5%), estimated as the quotient of the 51Cr-RBC volume divided by the sum of the 125I-BSA and the 51Cr-RBC volumes, also was significantly less than the dorsal aortic microhematocrit (36±4%). Estimates of total blood volumes in most tissues were significantly smaller when calculated from the51Cr-RBC data than when calculated by the other two methods. Tissue blood volumes were greatest in highly vascularized and well perfused tissues and least in poorly vascularized tissues. The relative degree of vascularization among tissues generally remained the same regardless of whether the red cell or the plasma tracer was used to calculated blood volume. It is not clear whether the expanded plasma volume is the result of the distribution of erythrocyte-poor blood into the secondary circulation or the result of extravascular exchange of plasma proteins.
Prostate-specific antigen lowering effect of metabolic syndrome is influenced by prostate volume.
Choi, Woo Suk; Heo, Nam Ju; Paick, Jae-Seung; Son, Hwancheol
2016-04-01
To investigate the influence of metabolic syndrome on prostate-specific antigen levels by considering prostate volume and plasma volume. We retrospectively analyzed 4111 men who underwent routine check-ups including prostate-specific antigen and transrectal ultrasonography. The definition of metabolic syndrome was based on the modified Adult Treatment Panel III criteria. Prostate-specific antigen mass density (prostate-specific antigen × plasma volume / prostate volume) was calculated for adjusting plasma volume and prostate volume. We compared prostate-specific antigen and prostate-specific antigen mass density levels of participants with metabolic syndrome (metabolic syndrome group, n = 1242) and without metabolic syndrome (non-prostate-specific antigen metabolic syndrome group, n = 2869). To evaluate the impact of metabolic syndrome on prostate-specific antigen, linear regression analysis for the natural logarithm of prostate-specific antigen was used. Patients in the metabolic syndrome group had significantly older age (P < 0.001), larger prostate volume (P < 0.001), higher plasma volume (P < 0.001) and lower mean serum prostate-specific antigen (non-metabolic syndrome group vs metabolic syndrome group; 1.22 ± 0.91 vs 1.15 ± 0.76 ng/mL, P = 0.006). Prostate-specific antigen mass density in the metabolic syndrome group was still significantly lower than that in the metabolic syndrome group (0.124 ± 0.084 vs 0.115 ± 0.071 μg/mL, P = 0.001). After adjusting for age, prostate volume and plasma volume using linear regression model, the presence of metabolic syndrome was a significant independent factor for lower prostate-specific antigen (prostate-specific antigen decrease by 4.1%, P = 0.046). Prostate-specific antigen levels in patients with metabolic syndrome seem to be lower, and this finding might be affected by the prostate volume. © 2016 The Japanese Urological Association.
Whole body and tissue blood volumes of two strains of rainbow trout (Oncorhynchus mykiss)
Gingerich, W.H.; Pityer, R.A.; Rach, J.J.
1990-01-01
1. Estimates of apparent packed cell, plasma and total blood volumes for the whole body and for 13 selected tissues were compared between Kamloops and Wytheville strains of rainbow trout (Oncorhynchus mykiss) by the simultaneous injection of two vascular tracers, radiolabeled trout erythrocytes (51Cr-RBC) and radioiodated bovine serum albumin (125I-BSA).2. Whole body total blood volume, plasma volume and packed cell volume were slightly, but not significantly greater in the Wytheville trout, whereas, the apparent plasma volumes and total blood volumes in 4 of 13 tissues were significantly greater in the Kamloops strain.3. Differences were most pronounced in highly perfused organs, such as the liver and kidney and in organs of digestion such as the stomach and intestines.4. Differences in blood volumes between the two strains may be related to the greater permeability of the vascular membranes in the Kamloops strain fish.
Destruction of newly released red blood cells in space flight
NASA Technical Reports Server (NTRS)
Alfrey, C. P.; Udden, M. M.; Huntoon, C. L.; Driscoll, T.
1996-01-01
Space flight results in a rapid change in total blood volume, plasma volume, and red blood cell mass because the space to contain blood is decreased. The plasma volume and total blood volume decreases during the first hours in space and remain at a decreased level for the remainder of the flight. During the first several hours following return to earth, plasma volume and total blood volume increase to preflight levels. During the first few days in space recently produced red blood cells disappear from the blood resulting in a decrease in red blood cell mass of 10-15%. Red cells 12 d old or older survive normally and production of new cells continues at near preflight levels. After the first few days in space, the red cell mass is stable at the decreased level. Following return to earth the hemoglobin and red blood cell mass concentrations decrease reflecting the increase in plasma volume. The erythropoietin levels increase responding to "postflight anemia"; red cell production increases, and the red cell mass is restored to preflight levels after several weeks.
21 CFR 606.122 - Instruction circular.
Code of Federal Regulations, 2012 CFR
2012-04-01
...: (1) Instructions to administer a suitable plasma volume expander if Red Blood Cells are substituted... approximate volume of plasma from which a sample unit of Platelets is prepared. (2) Instructions to begin administration as soon as possible, but not more than 4 hours after entering the container. (m) For Plasma, the...
Plasma volume methodology: Evans blue, hemoglobin-hematocrit, and mass density transformations
NASA Technical Reports Server (NTRS)
Greenleaf, J. E.; Hinghofer-Szalkay, H.
1985-01-01
Methods for measuring absolute levels and changes in plasma volume are presented along with derivations of pertinent equations. Reduction in variability of the Evans blue dye dilution technique using chromatographic column purification suggests that the day-to-day variability in the plasma volume in humans is less than + or - 20 m1. Mass density determination using the mechanical-oscillator technique provides a method for measuring vascular fluid shifts continuously for assessing the density of the filtrate, and for quantifying movements of protein across microvascular walls. Equations for the calculation of volume and density of shifted fluid are presented.
NASA Technical Reports Server (NTRS)
Davis, John E.
1989-01-01
Current operational procedures for shuttle crewmembers include the ingestion of a fluid countermeasure approximately 2 hours before reentry into the earth's gravitational field. The ingestion of the fluid countermeasure is thought to restore plasma volume and improve orthostatic responses upon reentry. The present countermeasure consists of ingesting salt tablets and water to achieve an isotonic solution. It has yet to be determined whether this is the optimal drink to restore orthostatic tolerance. It is also not known whether the drink solution is effective in increasing plasma volume. The purpose here is to evaluate the effectiveness of drink solutions of different osmolarity on restoring plasma volume and orthostatic responses. A hypertonic drink solution was more effective in restoring plasma volume after dehydration than an isotonic solution. However, there were no differences in their effects on an orthostatic challenge. These data suggest that the plasma volume differences produced in this study were not sufficient to produce differences in the cardiovascular responses to an orthostatic challenge, or there are other changes that occur during space flight that are more important in determining orthostatic intolerance.
Albumin infusion in humans does not model exercise induced hypervolaemia after 24 hours
NASA Technical Reports Server (NTRS)
Haskell, A.; Gillen, C. M.; Mack, G. W.; Nadel, E. R.
1998-01-01
We rapidly infused 234 +/- 3 mL of 5% human serum albumin in eight men while measuring haematocrit, haemoglobin concentration, plasma volume (PV), albumin concentration, total protein concentration, osmolality, sodium concentration, renin activity, aldosterone concentration, and atrial natriuretic peptide concentration to test the hypotheses that plasma volume expansion and plasma albumin content expansion will not persist for 24 h. Plasma volume and albumin content were expanded for the first 6 h after infusion (44.3 +/- 1.9-47.2 +/- 2.0 mL kg-1 and 1.9 +/- 0.1-2.1 +/- 0.1 g kg-1 at pre-infusion and 1 h, respectively, P < 0.05), but by 24 h plasma volume and albumin content decreased significantly from 1 h post-infusion and were not different from pre-infusion (44.8 +/- 1.9 mL kg-1 and 1.9 +/- 0.1 g kg-1, respectively). Plasma aldosterone concentration showed a significant effect of time over the 24 h after infusion (P < 0.05), and showed a trend to decrease at 2 h after infusion (167.6 +/- 32.5(-1) 06.2 +/- 13.4 pg mL-1, P = 0.07). These data demonstrate that a 6.8% expansion of plasma volume and 10.5% expansion of plasma albumin content by infusion does not remain in the vascular space for 24 h and suggest a redistribution occurs between the intravascular space and interstitial fluid space.
Is there resetting of central venous pressure in microgravity?
NASA Technical Reports Server (NTRS)
Convertino, V. A.; Ludwig, D. A.; Elliott, J. J.; Wade, C. E.
2001-01-01
In the early phase of the Space Shuttle program, NASA flight surgeons implemented a fluid-loading countermeasure in which astronauts were instructed to ingest eight 1-g salt tablets with 960 ml of water approximately 2 hours prior to reentry from space. This fluid loading regimen was intended to enhance orthostatic tolerance by replacing circulating plasma volume reduced during the space mission. Unfortunately, fluid loading failed to replace plasma volume in groundbased experiments and has proven minimally effective as a countermeasure against post-spaceflight orthostatic intolerance. In addition to the reduction of plasma volume, central venous pressure (CVP) is reduced during exposure to actual and groundbased analogs of microgravity. In the present study, we hypothesized that the reduction in CVP due to exposure to microgravity represents a resetting of the CVP operating point to a lower threshold. A lower CVP 'setpoint' might explain the failure of fluid loading to restore plasma volume. In order to test this hypothesis, we conducted an investigation in which we administered an acute volume load (stimulus) and measured responses in CVP, plasma volume and renal functions. If our hypothesis is true, we would expect the elevation in CVP induced by saline infusion to return to its pre-infusion levels in both HDT and upright control conditions despite lower vascular volume during HDT. In contrast to previous experiments, our approach is novel in that it provides information on alterations in CVP and vascular volume during HDT that are necessary for interpretation of the proposed CVP operating point resetting hypothesis.
Moderator's view: High-volume plasma exchange: pro, con and consensus.
Kaplan, Andre A
2017-09-01
I have been asked to comment on the pro and con opinions regarding high-volume plasma exchange. The authors of both positions have provided cogent arguments and a reasonable approach to choosing the exchange volume for any given therapeutic plasma exchange. The major issue of relevance in this discussion is the nature of the toxins targeted for removal. These parameters include molecular weight, the apparent volume of distribution, the degree of protein binding, the biologic and chemical half-life, and the severity and rapidity of its toxicity. © The Author 2017. Published by Oxford University Press on behalf of ERA-EDTA. All rights reserved.
NASA Astrophysics Data System (ADS)
Henault, M.; Wattieaux, G.; Lecas, T.; Renouard, J. P.; Boufendi, L.
2016-02-01
Nanoparticles growing or injected in a low pressure cold plasma generated by a radiofrequency capacitively coupled capacitive discharge induce strong modifications in the electrical parameters of both plasma and discharge. In this paper, a non-intrusive method, based on the measurement of the plasma impedance, is used to determine the volume averaged electron density and effective coupled power to the plasma bulk. Good agreements are found when the results are compared to those given by other well-known and established methods.
Plasma volume during stress in man - Osmolality and red cell volume
NASA Technical Reports Server (NTRS)
Greenleaf, J. E.; Convertino, V. A.; Mangseth, G. R.
1979-01-01
The purpose was (1) to test the hypothesis that in man there is a range of plasma osmolality within which the red cell volume (RCV) and mean corpuscular volume (MCV) remain essentially constant and (2) to determine the upper limit of this range. During a variety of stresses - submaximal and maximal exercise, heat and altitude exposure, +Gz acceleration, and tilting - changes in plasma osmolality between -1 and +13 mosmol/kg resulted in essentially no change in the regression of percent change in plasma volume (PV) calculated from a change in hematocrit (Hct) on that calculated from a change in Hct + hemoglobin (Hb), i.e., the RCV and MCV were constant. Factors that do not influence RCV are the level of metabolism, heat exposure at rest, and short-term orthostasis (heat-to-foot acceleration). Factors that may influence RCV are exposure to high altitude and long-term orthostasis (head-up tilting). Factors that definitely influence RCV are prior dehydration and extended periods of stress. Thus, either the Hct or the Hct + Hb equations can be used to calculate percent changes in PV under short-term periods of stress when the change in plasma osmolality is less than 13 mosmol/kg.
Capillary plasma jet: A low volume plasma source for life science applications
NASA Astrophysics Data System (ADS)
Topala, I.; Nagatsu, M.
2015-02-01
In this letter, we present results from multispectroscopic analysis of protein films, after exposure to a peculiar plasma source, i.e., the capillary plasma jet. This plasma source is able to generate very small pulsed plasma volumes, in kilohertz range, with characteristic dimensions smaller than 1 mm. This leads to specific microscale generation and transport of all plasma species. Plasma diagnosis was realized using general electrical and optical methods. Depending on power level and exposure duration, this miniature plasma jet can induce controllable modifications to soft matter targets. Detailed discussions on protein film oxidation and chemical etching are supported by results from absorption, X-ray photoelectron spectroscopy, and microscopy techniques. Further exploitation of principles presented here may consolidate research interests involving plasmas in biotechnologies and plasma medicine, especially in patterning technologies, modified biomolecule arrays, and local chemical functionalization.
Patterson, M J; Stocks, J M; Taylor, N A S
2014-04-01
This experiment was designed to test the hypothesis that the plasma volume is not selectively defended during exercise- and heat-induced dehydration following humid-heat acclimation. Eight physically active males were heat acclimated (39.8 °C, relative humidity 59.2%) using 17 days of controlled hyperthermia (core temperature: 38.5 °C). Inter-compartmental fluid losses and movements were tracked (radioisotopes and Evans blue dye) during progressive dehydration (cycling) in these same conditions and also during a resting recovery without fluid replacement (28 °C), before (day 1), during (day 8) and after heat acclimation (day 22). On days 8 and 22, there were significant increases in total body water, interstitial fluid and plasma volume (P < 0.05), but the intracellular compartments did not change (P > 0.05). The baseline plasma volume remained expanded throughout: 43.4 [±2.6 (day 1)], 49.1 [±2.4 (day 8); P < 0.05] and 48.9 mL kg(-1) [±3.0 (day 22); P < 0.05]. During progressive dehydration, plasma reductions of 9.0% (±0.9: day 1), 12.4% (±1.6: day 8) and 13.6% (±1.2: day 22) were observed, with day 8 and 22 losses significantly exceeding day 1 (P < 0.05). During recovery, plasma volume restoration commenced, with the intracellular fluid contribution becoming more pronounced as acclimation progressed. It is concluded that the plasma volume was not defended more vigorously following humid-heat acclimation. Indeed, a greater fluid loss may well underlie the mechanisms for enhancing plasma volume recovery when heat acclimation is induced using the controlled-hyperthermia technique. © 2013 Scandinavian Physiological Society. Published by John Wiley & Sons Ltd.
The effect of vitamin C on plasma volume in the early stage of sepsis in the rat.
Bark, Björn P; Grände, Per-Olof
2014-12-01
Previous experimental studies have shown that vitamin C has several beneficial effects in sepsis and burns, such as decreased tissue oedema, improved endothelial barrier function and decreased transcapillary leakage of plasma markers. It has still not been investigated, though, if vitamin C has any impact specifically on plasma volume. The present study aims at testing the hypothesis that vitamin C decreases plasma volume loss in sepsis. Anaesthetized male adult Sprague-Dawley rats were used in this prospective randomized study. All experiments were carried out at a university hospital laboratory. Sepsis was induced by caecal ligation and incision. After 3 h, vitamin C was given either as a bolus dose (66 mg/kg) followed by a continuous infusion (33 mg/kg/h) (n = 9), or as a single bolus dose (200 mg/kg) (n = 9). A sham group (n = 9) underwent the same surgical procedure, but no vitamin C was given. Plasma volume was measured ((125)I-dilution technique) at baseline, at 3 h after end of initiation of sepsis and at the end of the experiment 3 h later. Arterial blood samples for analyses of electrolytes, blood gases, haematocrit and lactate were taken at the same time points. There were no significant differences in plasma volumes or the physiological parameters analysed between any of the three groups at any time point. There was a significantly larger urine production in the single bolus dose group (200 mg/kg) compared to the sham group. Vitamin C treatment did not decrease the loss of plasma volume in the septic rat. The diuretic effect of vitamin C was in accordance with previous studies.
Plasma properties in electron-bombardment ion thrusters
NASA Technical Reports Server (NTRS)
Matossian, J. N.; Beattie, J. R.
1987-01-01
The paper describes a technique for computing volume-averaged plasma properties within electron-bombardment ion thrusters, using spatially varying Langmuir-probe measurements. Average values of the electron densities are defined by integrating the spatially varying Maxwellian and primary electron densities over the ionization volume, and then dividing by the volume. Plasma properties obtained in the 30-cm-diameter J-series and ring-cusp thrusters are analyzed by the volume-averaging technique. The superior performance exhibited by the ring-cusp thruster is correlated with a higher average Maxwellian electron temperature. The ring-cusp thruster maintains the same fraction of primary electrons as does the J-series thruster, but at a much lower ion production cost. The volume-averaged predictions for both thrusters are compared with those of a detailed thruster performance model.
Plasma volume and renal function during and after ultramarathon running.
Irving, R A; Noakes, T D; Burger, S C; Myburgh, K H; Querido, D; van Zyl Smit, R
1990-10-01
Plasma volume (PV) and renal function were studied in eight subjects for 3 d prior to and 6 d after a 56 km footrace. Immediately following the race, PV, creatinine clearance, and urine flow were unchanged from pre-race values. Over the subsequent 3 d, PV increased due initially to a 17 g influx of serum albumin and an associated increase in plasma sodium content, which persisted throughout the study period. A reduction in urine sodium secretion occurred during the race day. Creatinine clearance increased after the race and remained elevated for 48 h. Increases serum enzyme activities, C-reactive protein concentration, serum uric acid content, and plasma creatinine concentration and production suggest muscle damage. We suggested the following. First, the persistent post-exercise plasma volume expansion is initiated by an influx of albumin into the intravascular space with an associated increase in plasma sodium content. A decrease in urine sodium excretion during the race day would contribute to the latter. Second, the interpretation of post-race changes in serum constituents must take account of changes in plasma volume. Third, there is an increase in creatinine clearance, indicating an increase in glomerular filtration rate, after both standard and ultramarathon running. This may be caused by the products of muscle cell damage although the physiologic mechanism for this is unclear.
Kim, Ana; Fagan, Anne M; Goate, Alison M; Benzinger, Tammie LS; Morris, John C; Head, Denise
2015-01-01
Brain-derived neurotrophic factor (BDNF) has been shown to be important for neuronal survival and synaptic plasticity in the hippocampus in non-human animals. The Val66Met polymorphism in the BDNF gene, involving a valine (Val) to methionine (Met) substitution at codon 66, has been associated with lower BDNF secretion in vitro. However, there have been mixed results regarding associations between either circulating BDNF or the BDNF Val66Met polymorphism with hippocampal volume and memory in humans. The current study examined the association of BDNF genotype and plasma BDNF with hippocampal volume and memory in two large independent cohorts of middle-aged and older adults (both cognitively normal and early-stage dementia). Sample sizes ranged from 123 to 649. Measures of the BDNF genotype, plasma BDNF, MRI-based hippocampal volume and memory performance were obtained from the Knight Alzheimer Disease Research Center (ADRC) and the Alzheimer’s Disease Neuroimaging Initiative (ADNI). There were no significant differences between BDNF Met+ and Met- groups on either hippocampal volume or memory in either cohort. In addition, plasma BDNF was not significantly associated with either hippocampal volume or memory in either cohort. Neither age, cognitive status nor gender moderated any of the relationships. Overall, current findings suggest that BDNF genotype and plasma BDNF may not be robust predictors for variance in hippocampal volume and memory in middle age and older adult cohorts. PMID:25784293
Relation of blood volume and blood pressure in orthostatic intolerance
NASA Technical Reports Server (NTRS)
Jacob, G.; Biaggioni, I.; Mosqueda-Garcia, R.; Robertson, R. M.; Robertson, D.
1998-01-01
A complex but crucial relationship exists between blood volume and blood pressure in human subjects; it has been recognized that in essential hypertension, renovascular hypertension, and pheochromocytoma, the relationship between plasma volume and diastolic blood pressure is an inverse one. This phenomenon has not been studied in individuals with low normal and reduced blood pressures. Orthostatic intolerance is a commonly encountered abnormality in blood pressure regulation often associated with tachycardia in the standing position. Most of these patients have varying degrees of reduced blood volume. We tested the hypothesis that the relationship previously found between plasma volume and diastolic blood pressure in pressor states would also hold in orthostatic intolerance. We studied 16 patients with a history of symptomatic orthostatic intolerance associated with an elevation in plasma norepinephrine in the upright posture and hypovolemia in 9 patients and normovolemia in 7 patients. Our studies demonstrate an inverse relationship between plasma volume and diastolic blood pressure in patients with orthostatic intolerance. This finding also holds for the change in diastolic blood pressure in response to upright posture. In this relationship, patients with orthostatic intolerance with high plasma norepinephrine resemble those with essential hypertension, renovascular hypertension, and pheochromocytoma. We conclude that in a variety of conditions at both ends of the blood pressure spectrum, the seemingly paradoxical association of hypovolemia and diastolic blood pressure is preserved.
West, Crystal; Zhang, Zheng; Ecker, Geoffrey; Masilamani, Shyama M E
2010-11-01
Pregnancy-mediated sodium (Na) retention is required to provide an increase in plasma volume for the growing fetus. The mechanisms responsible for this Na retention are not clear. We first used a targeted proteomics approach and found that there were no changes in the protein abundance compared with virgin rats of the β or γ ENaC, type 3 Na(+)/H(+) exchanger (NHE3), bumetanide-sensitive cotransporter (NKCC2), or NaCl cotransporter (NCC) in mid- or late pregnancy. In contrast, we observed marked increases in the abundance of the α-ENaC subunit. The plasma volume increased progressively during pregnancy with the greatest plasma volume being evident in late pregnancy. ENaC inhibition abolished the difference in plasma volume status between virgin and pregnant rats. To determine the in vivo activity of ENaC, we conducted in vivo studies of rats in late pregnancy (days 18-20) and virgin rats to measure the natriuretic response to ENaC blockade (with benzamil). The in vivo activity of ENaC (U(Na)V postbenzamil-U(Na)V postvehicle) was markedly increased in late pregnancy, and this difference was abolished by pretreatment with the mineralocorticoid receptor antagonist, eplerenone. These findings demonstrate that the increased α-ENaC subunit of pregnancy is associated with an mineralocorticoid-dependent increase in ENaC activity. Further, we show that ENaC activity is a major contributor of plasma volume status in late pregnancy. These changes are likely to contribute to the renal sodium retention and plasma volume expansion required for an optimal pregnancy.
Smith, A M J; Bonato, M; Dzama, K; Malecki, I A; Cloete, S W P
2018-06-01
Successful assisted reproduction techniques, with specific focus on in vitro semen storage for artificial insemination, are dependent on certain key elements which includes the biochemical profiling of semen. The objective of this study was to complete an ostrich seminal plasma (SP) evaluation by inductively coupled plasma mass spectrometry (ICP-MS) among seven males at different daily intervals (day 1, 3, 7, 11, 15, 19, 21, 23, 25, 26, 27, 28) for a period of 28 days during spring (August to September) for mineral profiling. The effect of collection day and male on sperm concentration, semen volume and seminal plasma volume, was explored as well as the relationships amongst these specific sperm traits and SP minerals. Variation amongst SP mineral concentrations, accounted for by the fixed effects of sperm concentration, semen volume, seminal plasma volume, collection day and male, ranged from 18% to 77%. Male had the largest effect on variation in SP minerals, namely: phosphorus (P), potassium (K), calcium (Ca), sodium (Na), boron (B), iron (Fe), cobalt (Co), nickel (Ni), copper (Cu), molybdenum (Mo), barium (Ba), arsenic (As) and selenium (Se). Sperm concentration instigated fluctuations of P, magnesium (Mg), B, zinc (Zn), Fe, aluminium (Al), Se, manganese (Mn) and lead (Pb). Semen volume had an effect on Na, K, B, Pb and Ba while seminal plasma volume only influenced variation in Na. There were fluctuations among collection days of specific micro minerals, Ni and Mo, with initial Ni concentrations being relatively greater and Mo at lesser concentrations. Semen volume, seminal plasma volume and sperm concentration varied amongst males. Sperm concentrations during the initial collection days, 1 and 3, were less than that for days 7 to 28. Significant variation of SP minerals and sperm characteristics among ejaculates and males suggest an association of these specific elements with sperm function and are, therefore, considered to be of potential importance to success of assisted reproduction technology for the ostrich. The relationship amongst sperm concentration and collection day confirms the need to conduct an initial period of collection to stabilise a greater sperm concentration to optimise sperm numbers for artificial insemination purposes. Copyright © 2018 Elsevier B.V. All rights reserved.
Dietary sodium and plasma volume levels with exercise.
Luetkemeier, M J; Coles, M G; Askew, E W
1997-05-01
Sodium is the major cation of the extracellular fluid and has a potent influence on fluid movement. Sodium has been likened to a sponge that draws fluids into the extracellular space, including the plasma volume, to equalize gradients in concentration. Conventional wisdom suggests limiting dietary intake of Na+ to decrease risk of hypertension. However, there are some extreme occupational or exercise-related conditions where sweat losses are great and Na+ losses may exceed normal dietary intake. This can occur acutely such as in an ultra-endurance event or chronically as in hard manual work in the hear. In such cases, additional Na+ in the form of a higher Na+ diet or adding Na+ to beverages used for fluid replacement may be warranted. A higher Na+ diet also appears to accelerate the cardiovascular and thermoregulatory adaptations that accompany heat acclimation or short term exercise training. Saline ingestion before exercise causes an expansion of plasma volume at rest and throughout the subsequent exercise bout. This expansion of plasma volume alters cardiovascular and thermoregulatory responses to exercise in ways that may lead to beneficial changes in endurance exercise performance. Plasma volume expansion also occurs with saline infusion during exercise, but exercise performance advantages have yet to be reported. The purpose of this article is to review the literature concerning dietary sodium and its influence on fluid balance, plasma volume and thermoregulation during exercise. It contains 2 major sections. First, we will discuss manipulations in daily Na+ intake initiated before or throughout an exercise regime. Second, we will examine studies where an acute Na+ load was administered immediately before or during an exercise trial. The dependent variables that we will discuss pertain to: (i) body water compartments, i.e. plasma volume; (ii) thermoregulatory variables, i.e. core temperature and sweat rate; (iii) cardiovascular variables, i.e. heart rate and stroke volume; and (iv) performance, i.e. time trial performance and time to exhaustion. Particular attention will be given to the route by which Na+ was administered, the environmental conditions, the level of acclimation of the participants and specifics relating to Na+ administration such as the osmolality of the Na(+)-containing beverage.
NASA Technical Reports Server (NTRS)
Tucker, Bryan J.; Mendonca, Margarida M.
1995-01-01
Transition from a normal gravitational environment to that of microgravity eventually results in decreased plasma and blood volumes, increasing with duration of exposure to microgravity. This loss of vascular fluid is presumably due to negative fluid and electrolyte balance and most likely contributes to the orthostatic intolerance associated with the return to gravity. The decrease in plasma volume is presumed to be a reflection of a concurrent decrease in extracellular fluid volume with maintenance of normal plasma-interstitial fluid balance. In addition, the specific alterations in renal function contributing to these changes in fluid and electrolyte homeostasis are potentially responding to neuro-humoral signals that are not consistent with systemic fluid volume status. We have previously demonstrated an early increase in both glomerular filtration rate and extracellular fluid volume and that this decreases towards control values by 7 days of simulated microgravity. However, longer duration studies relating these changes to plasma volume alterations and the response to return to orthostasis have not been fully addressed. Male Wistar rats were chronically cannulated, submitted to 30 days heat-down tilt (HDT) and followed for 7 days after return to orthostasis from HDT. Measurements of renal function and extracellular and blood volumes were performed in the awake rat.
Body Fluid Regulation and Hemopoiesis in Space Flight
NASA Technical Reports Server (NTRS)
1997-01-01
In this session, Session JA2, the discussion focuses on the following topics: Bodymass and Fluid Distribution During Longterm Spaceflight with and without Countermeasures; Plasma Volume, Extracellular Fluid Volume, and Regulatory Hormones During Long-Term Space Flight; Effect of Microgravity and its Ground-Based Models on Fluid Volumes and Hemocirculatory Volumes; Seventeen Weeks of Horizontal Bed Rest, Lower Body Negative Pressure Testing, and the Associated Plasma Volume Response; Evaporative Waterloss in Space Theoretical and Experimental Studies; Erythropoietin Under Real and Simulated Micro-G Conditions in Humans; and Vertebral Bone Marrow Changes Following Space Flight.
Fludrocortisone does not prevent orthostatic hypotension in astronauts after spaceflight.
Shi, Shang-Jin; South, Donna A; Meck, Janice V
2004-03-01
During stand/tilt tests after spaceflight, 20% of astronauts experience orthostatic hypotension and presyncope. Spaceflight-induced hypovolemia is a contributing factor. Fludrocortisone, a synthetic mineralocorticoid, has been shown to increase plasma volume and orthostatic tolerance in Earth-bound patients. The efficacy of fludrocortisone as a treatment for postflight hypovolemia and orthostatic hypotension in astronauts has not been studied. Our purpose was to test the hypothesis that astronauts who ingest fludrocortisone prior to landing would have less loss of plasma volume and greater orthostatic tolerance than astronauts who do not ingest fludrocortisone. There were 25 male astronauts who were randomized into 2 groups: placebo (n = 18) and fludrocortisone (n = 7), and participated in stand tests 10 d before launch and 2-4 h after landing. Subjects took either 0.3 mg fludrocortisone or placebo orally 7 h prior to landing. Supine plasma and red cell volumes, supine and standing HR, arterial pressure, aortic outflow, and plasma norepinephrine and epinephrine were measured. On landing day, 2 of 18 in the placebo group and 1 of 7 in the fludrocortisone group became presyncopal (chi2 = 0.015, p = 0.90). Plasma volumes were significantly decreased after flight in the placebo group, but not in the fludrocortisone group. During postflight stand tests, standing plasma norepinephrine was significantly less in the fludrocortisone group compared with the placebo group. Treatment with a single dose of fludrocortisone results in protection of plasma volume but no protection of orthostatic tolerance. Fludrocortisone is not recommended as a countermeasure for spaceflight-induced orthostatic intolerance.
Intravascular volume in cirrhosis. Reassessment using improved methodology
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rector, W.G. Jr.; Ibarra, F.
1988-04-01
Previous studies of blood volume (BV) in cirrhosis have either not adjusted BV properly for body size; determined plasma volume from the dilution of labeled albumin 10-20 min postinjection, when some extravascular redistribution has already occurred; and/or not used the correct whole body-peripheral hematocrit ratio (0.82) in calculating whole BV from plasma volume and the peripheral hematocrit. We measured BV with attention to these considerations in 19 patients with cirrhosis and reexamined the determinants of vascular volume and the relationship between vascular volume and sodium retention. BV was calculated as plasma volume (determined from extrapolated plasma activity of intravenously injectedmore » (/sup 131/I)+albumin at time 0) divided by (peripheral hematocrit X 0.82). The result was expressed per kilogram dry body weight, determined by subtracting the mass of ascites (measured by isotope dilution; 1 liter = 1 kg) from the actual body weight of nonedematous patients. Measured and expressed in this way, BV correlated strongly with esophageal variceal size (r = 0.87, P less than 0.05), although not with net portal, right atrial, inferior vena caval, or arterial pressure, and was significantly greater in patients with sodium retention as compared to patients without sodium retention. The principal modifier of vascular volume in cirrhosis is vascular capacity, which is probably mainly determined by the extent of the portasystemic collateral circulation. Increased vascular volume in patients with sodium retention as compared to patients without sodium retention supports the overflow theory of ascites formation.« less
Fernández, Purificación; Fernández, Ana M; Bermejo, Ana M; Lorenzo, Rosa A; Carro, Antonia M
2013-04-01
The performance of microwave-assisted extraction and HPLC with photodiode array detection method for determination of six analgesic and anti-inflammatory drugs from plasma and urine, is described, optimized, and validated. Several parameters affecting the extraction technique were optimized using experimental designs. A four-factor (temperature, phosphate buffer pH 4.0 volume, extraction solvent volume, and time) hybrid experimental design was used for extraction optimization in plasma, and three-factor (temperature, extraction solvent volume, and time) Doehlert design was chosen to extraction optimization in urine. The use of desirability functions revealed the optimal extraction conditions as follows: 67°C, 4 mL phosphate buffer pH 4.0, 12 mL of ethyl acetate and 9 min, for plasma and the same volume of buffer and ethyl acetate, 115°C and 4 min for urine. Limits of detection ranged from 4 to 45 ng/mL in plasma and from 8 to 85 ng/mL in urine. The reproducibility evaluated at two concentration levels was less than 6.5% for both specimens. The recoveries were from 89 to 99% for plasma and from 83 to 99% for urine. The proposed method was successfully applied in plasma and urine samples obtained from analgesic users. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
1987-09-01
capillaries (4), blood volumes calculated from plasma volume measures must correct for label that has left the system between the time of the injected dose...Splenic sequestration and contraction are mediated by the autonomic nervous system and blood-borne agents (10). Sympathetic nerve fibers from the truncus...sympathlcus and parasympathetic neurons of the nervus vagus (cranial nerve X) innervate the celiac plexus (8, 11). A subdivision of the celiac plexus
Endocrine considerations in the red-cell-mass and plasma volume changes of the Skylab 2 and 3 crews
NASA Technical Reports Server (NTRS)
Johnson, P. C.; Leach, C. S.; Driscoll, T.
1975-01-01
The effect of unknown endocrine changes on blood volume of crewmembers was investigated. The results are presented in tabular form. The fact that some of the changes were in the wrong direction suggests that changes in endocrine function were not the primary cause of the decreases in the plasma volume and red cell mass.
Numerical Analysis of Plasma Transport in Tandem Volume Magnetic Multicusp Ion Sources
1992-03-01
the results of the model are qualitatively correct. Boltzmann Equation, Ion Sources, Plasma Simulation, Electron Temperature, Plasma Density, Ion Temperature, Hydrogen Ions, Magnetic Filters, Hydrogen Plasma Chemistry .
Gernand, Alison D; Christian, Parul; Schulze, Kerry J; Shaikh, Saijuddin; Labrique, Alain B; Shamim, Abu Ahmed; West, Keith P
2012-06-01
Plasma volume expansion has been associated with fetal growth. Our objective was to examine the associations between maternal nutritional status in early pregnancy and extracellular water (ECW), total body water (TBW), and percentage plasma volume change across pregnancy. In a subsample of 377 pregnant women participating in a cluster-randomized trial of micronutrient supplementation, hemoglobin, hematocrit, and multi-frequency bioelectrical impedance were measured at ~10, 20, and 32 wk of gestation. In early pregnancy, women were short (mean ± SD, 148.9 ± 5.3 cm) and thin (19.5 ± 2.5 kg/m(2)). In mixed-effects multiple regression models, a 1-unit higher BMI at ~10 wk was associated with higher ECW and TBW (0.27 and 0.66 kg per kg/m(2), respectively; P < 0.01) at ~10, ~20, and ~32 wk. Height was also positively associated with ECW and TBW at each time point. Early pregnancy BMI was negatively associated with gains in ECW and TBW (-0.06 and -0.14 kg per kg/m(2), respectively; P < 0.01) from 10 to 20 wk, but not with 20- to 32-wk gains after accounting for weight gain. BMI was positively associated with percentage changes in plasma volume from 20 to 32 wk (0.57% per kg/m(2); P < 0.05). Height was not associated with changes in body water or plasma volume. Women with low BMI and height in early pregnancy have lower ECW and TBW in early, mid, and late pregnancy and lower late pregnancy plasma volume expansion, potentially increasing risk of fetal growth restriction.
Cantero, Jose L; Iglesias, Juan E; Van Leemput, Koen; Atienza, Mercedes
2016-09-01
Evidence suggests a link between the presence of subjective memory complaints (SMC) and lower volume of the hippocampus, one of the first regions to show neuropathological lesions in Alzheimer's disease. However, it remains unknown whether this pattern of hippocampal atrophy is regionally specific and whether SMC are also paralleled by changes in peripheral levels of amyloid-beta (Aβ). The volume of hippocampal subregions and plasma Aβ levels were cross-sectionally compared between elderly individuals with (SMC(+); N = 47) and without SMC (SMC(-); N = 48). Significant volume differences in hippocampal subregions were further correlated with plasma Aβ levels and with objective memory performance. Individuals with SMC exhibited significantly higher Aβ1-42 concentrations and lower volumes of CA1, CA4, dentate gyrus, and molecular layer compared with SMC(-) participants. Regression analyses further showed significant associations between lower volume of the dentate gyrus and both poorer memory performance and higher plasma Aβ1-42 levels in SMC(+) participants. The presence of SMC, lower volumes of specific hippocampal regions, and higher plasma Aβ1-42 levels could be conditions associated with aging vulnerability. If such associations are confirmed in longitudinal studies, the combination may be markers recommending clinical follow-up in nondemented older adults. © The Author 2016. Published by Oxford University Press on behalf of The Gerontological Society of America. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Changes in renal function and fluid and electrolyte regulation in space flight
NASA Technical Reports Server (NTRS)
Leach, C. S.
1992-01-01
The cephalad fluid redistribution resulting from weightlessness has a number of physiologic consequences. Plasma volume is reduced soon after weightlessness is reached, and red blood cell mass reduction follows. Plasma atrial natriuretic peptide, which inhibits aldosterone secretion, was elevated during space flight while plasma aldosterone was below preflight levels. Serum sodium was also reduced and potassium was elevated. Antidiuretic hormone (ADH) was markedly elevated at almost all measurement times in the first eight days of flight, but plasma volume did not return to preflight levels.
Hypervolemia and plasma vasopressin response during water immersion in men
NASA Technical Reports Server (NTRS)
Greenleaf, J. E.; Morse, J. T.; Barnes, P. R.; Silver, J.; Keil, L. C.
1983-01-01
Immersion studies were performed on seven mildly dehydrated male subjects to examine the effect of suppression of plasma vasopressin (PVP) on diuresis in water immersion. The water was kept at close to 34.5 C and the subjects remained in the water for 4 hr after sitting for 2 hr. Na and K levels in the serum and urine were analyzed, as were osmolality, red blood cell count, renin activity, total protein, albumin amounts, hematocrit, and hemoglobin. Plasma volume was monitored from samples drawn at specified intervals during immersion. The plasma volume increased significantly 30 min after immersion, but no PVP was observed. The dehydration induced elevated serum osmotic concentrations. It is concluded that the hydration condition before immersion and the volume of fluid intake during immersion affects the hemodilution during immersion.
A High-Efficiency Superhydrophobic Plasma Separator
Liu, Changchun; Liao, Shih-Chuan; Song, Jinzhao; Mauk, Michael G.; Li, Xuanwen; Wu, Gaoxiang; Ge, Dengteng; Greenberg, Robert M.; Yang, Shu; Bau, Haim H.
2016-01-01
To meet stringent limit-of-detection specifications for low abundance target molecules, a relatively large volume of plasma is needed for many blood-based clinical diagnostics. Conventional centrifugation methods for plasma separation are not suitable for on-site testing or bedside diagnostics. Here, we report a simple, yet high-efficiency, clamshell-style, superhydrophobic plasma separator that is capable of separating a relatively large volume of plasma from several hundred microliters of whole blood (finger-prick blood volume). The plasma separator consists of a superhydrophobic top cover with a separation membrane and a superhydrophobic bottom substrate. Unlike previously reported membrane-based plasma separators, the separation membrane in our device is positioned at the top of the sandwiched whole blood film to increase the membrane separation capacity and plasma yield. In addition, the device’s superhydrophobic characteristics (i) facilitates the formation of well-defined, contracted, thin blood film with a high contact angle; (ii) minimizes biomolecular adhesion to surfaces; (iii) increases blood clotting time; and (iv) reduces blood cell hemolysis. The device demonstrated a “blood in-plasma out” capability, consistently extracting 65±21.5 μL of plasma from 200 μL of whole blood in less than 10 min without electrical power. The device was used to separate plasma from Schistosoma mansoni genomic DNA-spiked whole blood with a recovery efficiency of > 84.5 ± 25.8 %. The S. mansoni genomic DNA in the separated plasma was successfully tested on our custom-made microfluidic chip by using loop mediated isothermal amplification (LAMP) method. PMID:26732765
Thermonuclear inverse magnetic pumping power cycle for stellarator reactor
Ho, Darwin D.; Kulsrud, Russell M.
1991-01-01
The plasma column in a stellarator is compressed and expanded alternatively in minor radius. First a plasma in thermal balance is compressed adiabatically. The volume of the compressed plasma is maintained until the plasma reaches a new thermal equilibrium. The plasma is then expanded to its original volume. As a result of the way a stellarator works, the plasma pressure during compression is less than the corresponding pressure during expansion. Therefore, negative work is done on the plasma over a complete cycle. This work manifests itself as a back-voltage in the toroidal field coils. Direct electrical energy is obtained from this voltage. Alternatively, after the compression step, the plasma can be expanded at constant pressure. The cycle can be made self-sustaining by operating a system of two stellarator reactors in tandem. Part of the energy derived from the expansion phase of a first stellarator reactor is used to compress the plasma in a second stellarator reactor.
Elevated central venous pressure: A consequence of exercise training-induced hypervolemia
NASA Technical Reports Server (NTRS)
Convertino, Victor A.; Mack, Gary W.; Nadel, Ethan R.
1990-01-01
Resting plasma volumes, and arterial and central venous pressures (CVP) were measured in 16 men before and after exercise training to determine if training-induced hypervolemia could be explained by a change in total vascular capacitance. In addition, resting levels of plasma vasopressin (AVP), atrial natriuretic peptide (ANP), aldosterone (ALD), and norepinephrine (NE) were measured before and after training. The same measurements of vacular volume, pressures, and plasma hormones were measured in 8 subjects who did not undergo exercise and acted as controls. The exercise training program consisted of 10 weeks of controlled cycle exercise for 30 min/d, 4 d/wk at 75 to 80 percent of maximal oxygen uptake (VO2max). A training effect was verified by a 20 percent increase in VO2max, a resting bradycardia, and a 370 ml (9 percent) increase in blood volume. Mean arterial blood pressure was unaltered by exercise training, but resting CVP increased. The percent change in blood volume from before to after training was linearly related to the percent change in CVP. As a consequence of elevations in both blood volume and CVP, the volume-to-pressure ratio was essentially unchanged following exercise training. Plasma AVP, ANP, ALD, and NE were unaltered. Results indicate that elevated CVP is a consequence of training-induced hypervolemia without alteration in total effective venous capacitance. This may represent a resetting of the pressure-volume stimulus-response relation for regulation of blood volume.
Passino, Claudio; Maria Sironi, Anna; Favilli, Brunella; Poletti, Roberta; Prontera, Concetta; Ripoli, Andrea; Lombardi, Massimo; Emdin, Michele
2005-09-15
Atrial and brain natriuretic peptides (ANP and BNP) plasma concentration increases and holds a prognostic significance in patients with left ventricular dysfunction. We assessed the hypothesis that right ventricular (RV) overload might significantly contribute to plasma elevation of cardiac natriuretic hormones in patients with heart failure. Forty-one patients with cardiomyopathy and depressed left ventricular (LV) function (ejection fraction, EF, <40%), underwent cardiac magnetic resonance imaging (MRI) and resting plasma determination of ANP and BNP. Nineteen healthy subjects were also studied as control group. Ventricular volumes and function were assessed by MRI. In the group of patients, LVEF was 22.6+/-1.2% (controls: 61.2+/-1.3%, P<0.001, mean+/-S.E.M.), while RVEF was 48.2+/-2.5% (controls: 66.7+/-1.6%, P<0.001); LV and RV end diastolic/systolic volumes, corrected by body surface area, were 143+/-7/114+/-7 ml/m2 (controls 70+/-3/27+/-2 ml/m2, both P<0.001) and 66+/-3/37+/-4 ml/m2 (controls: 63+/-4/21+/-2 ml/m2, P<0.01 only for end-systolic volume). BNP plasma value was on average 324+/-39 pg/ml (range: 23-1280, controls 10+/-2 pg/ml), ANP value was 144+/-17 pg/ml (range: 26-534, controls 15+/-1 pg/ml). BNP positively correlated with either end-diastolic or end-systolic RV volume in patients, less with LV systolic, and not with LV diastolic volume. Moreover, a significant negative correlation was observed between BNP and either LVEF or RVEF. Conversely, ANP showed a significant correlation only with end-systolic RV volume and with both RVEF and LVEF. When multivariate stepwise linear regression analysis was applied LVEF resulted the only independent predictor for ANP plasma values (R=0.591, P<0.001), while LVEF and RV end-diastolic volume for BNP (R=0.881, P<0.001, and R=0.881, P=0.035, respectively). Right heart overload contributes independently to plasma elevation of natriuretic peptides. RV involvement, which is known to independently worsen prognosis in patients with cardiomyopathy, might contribute to their established prognostic power, inducing compensatory secretion of plasma cardiac natriuretic hormones.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schneider, K.W.; Becker, G.
1962-09-12
Blood volume was determined by the Evans blue and the Cr/sup 51/ methods in 40 normals and 17 cases of polycythemia. In normals there was good agreement of the results of both methods, however, in polycythemia differences were observed. With the Crsl-method the erythrocyte volume was found to be lower than with the Evans blue technique although the difference was not significant. When the active circulating blood volume is determined, the introduction of a correction factor for the so-called body hematocrit is not necessary. lt is possible that the difference between venous hematocrit and the quotient Evans blueplasma volume/Cr/sup 51/more » erythrocyte volume is caused by an increase of the error due to the trapped plasma. In case with increased hematocrit values the plasma volume should be determined by Evans blue and the erythrocyte volume by Cr/ sup 51/. In polycythemia the mean values were lower the those previously estimated by Seyderheim and Lampe. In the untreated state of polycythemia the mean plasma volume is reduced; in 80% of the cases a reduction was found initially. With successful treatment the plasma volume increased. Treatment consisted of injection of 0.08-0.09 mC P/sup 32/ per kg body wt, which was repeated three months later if necessary. Half the patients required only one such dose for remission; only one required three doses. Improvement in plasma volume showed no correlation with the size of the spleen or the presence of hypertension. The venous pressure was normal in all cases. Circulation time was variable but showed a tendency to become shorter following treatment with P/sup 32/. Renal function studies are discussed. Creatinine-clearance and phenolsulfonphthalein (PSP) excretion were often reduced, and albuminuria, hematuria, and azotemia were present. With clinical improvement after P/sup 32/ treatment these symptoms are reversible except for the reduced PSP excretion. (BBB)« less
Production of large resonant plasma volumes in microwave electron cyclotron resonance ion sources
Alton, Gerald D.
1998-01-01
Microwave injection methods for enhancing the performance of existing electron cyclotron resonance (ECR) ion sources. The methods are based on the use of high-power diverse frequency microwaves, including variable-frequency, multiple-discrete-frequency, and broadband microwaves. The methods effect large resonant "volume" ECR regions in the ion sources. The creation of these large ECR plasma volumes permits coupling of more microwave power into the plasma, resulting in the heating of a much larger electron population to higher energies, the effect of which is to produce higher charge state distributions and much higher intensities within a particular charge state than possible in present ECR ion sources.
Hara, Shuuji; Uchiyama, Masanobu; Yoshinari, Masami; Matsumoto, Taichi; Jimi, Shiro; Togawa, Atsushi; Takata, Tohru; Takamatsu, Yasushi
2015-09-01
Linezolid is an antimicrobial agent for the treatment of multiresistant Gram-positive infections. A practical high-performance liquid chromatography method was developed for the determination of linezolid in human plasma and saliva. Linezolid and an internal standard (o-ethoxybenzamide) were extracted from plasma and saliva with ethyl acetate and analyzed on a Capcell Pak C18 MG column with UV detection at 254 nm. The calibration curve was linear through the range 0.5-50 µg/mL using a 200 μL sample volume. The intra- and interday precisions were all <6.44% for plasma and 5.60% for saliva. The accuracies ranged from 98.8 to 110% for both matrices. The mean recoveries of linezolid were 80.8% for plasma and 79.0% for saliva. This method was used to determine the plasma and saliva concentrations of linezolid in healthy volunteers who were orally administered a 600 mg dose of linezolid. Our liquid-liquid extraction procedure is easy and requires a small volume of plasma or saliva (200 μL). This small volume can be advantageous in clinical pharmacokinetic studies, especially if children participate. Copyright © 2015 John Wiley & Sons, Ltd.
Finazzi, Stefano; Garbero, Elena; Trussardi, Giampietro; Bertolini, Guido
2017-05-01
Coupled plasma filtration and adsorption (CPFA) is an extracorporeal blood purification technique proposed for the treatment of septic-shock. By removing pro- and anti-inflammatory mediators from plasma, CPFA is supposed to have a therapeutic effect on the abnormal inflammatory response seen in this condition. Recently, blood predilution with citrate solution has been adopted to prevent clotting in the CPFA circuit-one of the main problems of the technique. Taking into account the patient's hematocrit, we worked out a formula for the volume of plasma effectively treated by CPFA after predilution. Neglecting this effect, as is commonly done, introduces significant distortions in the estimation of the volume, possibly causing under-treatment. The distortion is stronger when the hematocrit and the predilution fraction are large and weaker when both values shrink. By correctly indicating the daily dose of plasma adsorption received by patients, this formula is essential for assessing the therapeutic efficacy of CPFA and, subsequently, establishing its optimal doses. © 2017 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
Lee, Yonghun; Kim, Dong-Min; Li, Zhenglin; Kim, Dong-Eun; Kim, Sung-Jin
2018-03-13
We demonstrate a microfiltration chip that separates blood plasma by using water-head-driven pulsatile pressures rather than any external equipment and use it for on-chip amplification of nucleic acids. The chip generates pulsatile pressures to significantly reduce filter clogging without hemolysis, and consists of an oscillator, a plasma-extraction pump, and filter units. The oscillator autonomously converts constant water-head pressure to pulsatile pressure, and the pump uses the pulsatile pressure to extract plasma through the filter. Because the pulsatile pressure can periodically clear blood cells from the filter surface, filter clogging can be effectively reduced. In this way, we achieve plasma extraction with 100% purity and 90% plasma recovery at 15% hematocrit. During a 10 min period, the volume of plasma extracted was 43 μL out of a 243 μL extraction volume at 15% hematocrit. We also studied the influence of the pore size and diameter of the filter, blood loading volume, oscillation period, and hematocrit level on the filtration performance. To demonstrate the utility of our chip for point-of-care testing (POCT) applications, we successfully implemented on-chip amplification of a nucleic acid (miDNA21) in plasma filtered from blood. We expect our chip to be useful not only for POCT applications but also for other bench-top analysis tools using blood plasma.
Interaction of nanosecond ultraviolet laser pulses with reactive dusty plasma
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wetering, F. M. J. H. van de; Oosterbeek, W.; Beckers, J.
2016-05-23
Even though UV laser pulses that irradiate a gas discharge are small compared to the plasma volume (≲3%) and plasma-on time (≲6 × 10{sup −6}%), they are found to dramatically change the discharge characteristics on a global scale. The reactive argon–acetylene plasma allows the growth of nanoparticles with diameters up to 1 μm, which are formed inside the discharge volume due to spontaneous polymerization reactions. It is found that the laser pulses predominantly accelerate and enhance the coagulation phase and are able to suppress the formation of a dust void.
Järvelä, K; Koskinen, M; Kaukinen, S; Kööbi, T
2001-04-01
To compare the effects of hypertonic (7.5%) saline (HS), normal (0.9%) saline (NS), and 6% hydroxyethyl starch (HES) on extracellular fluid volumes in the early postoperative period after cardiopulmonary bypass. A prospective, randomized, double-blind study. University teaching hospital. Forty-eight patients scheduled for elective coronary artery bypass graft surgery. Patients were randomly allocated to receive 4 mL/kg of HS, NS, or HES during 30 minutes when volume loading was needed during the postoperative rewarming period in the intensive care unit. Plasma volume was measured using a dilution of iodine-125-labeled human serum albumin. Extracellular water and cardiac output were measured by whole-body impedance cardiography. Plasma volume had increased by 19 +/- 7% in the HS group and by 10 +/- 3% in the NS group (p = 0.001) at the end of the study fluid infusion. After 1-hour follow-up time, the plasma volume increase was greatest (23 +/- 8%) in the group receiving HES (p < 0.001). The increase of extracellular water was greater than the infused volume in the HS and HES groups at the end of the infusion. One-hour diuresis after the study infusion was greater in the HS group (536 +/- 280 mL) than in the NS (267 +/- 154 mL, p = 0.006) and HES groups (311 +/- 238 mL, p = 0.025). The effect of HS on plasma volume was short-lasting, but it stimulated excretion of excess body fluid accumulated during cardiopulmonary bypass and cardiac surgery. HS may be used in situations in which excess free water administration is to be avoided but the intravascular volume needs correction. Copyright 2001 by W.B. Saunders Company
Production of large resonant plasma volumes in microwave electron cyclotron resonance ion sources
Alton, G.D.
1998-11-24
Microwave injection methods are disclosed for enhancing the performance of existing electron cyclotron resonance (ECR) ion sources. The methods are based on the use of high-power diverse frequency microwaves, including variable-frequency, multiple-discrete-frequency, and broadband microwaves. The methods effect large resonant ``volume`` ECR regions in the ion sources. The creation of these large ECR plasma volumes permits coupling of more microwave power into the plasma, resulting in the heating of a much larger electron population to higher energies, the effect of which is to produce higher charge state distributions and much higher intensities within a particular charge state than possible in present ECR ion sources. 5 figs.
Hemodynamic and ADH responses to central blood volume shifts in cardiac-denervated humans
NASA Technical Reports Server (NTRS)
Convertino, V. A.; Thompson, C. A.; Benjamin, B. A.; Keil, L. C.; Savin, W. M.; Gordon, E. P.; Haskell, W. L.; Schroeder, J. S.; Sandler, H.
1990-01-01
Hemodynamic responses and antidiuretic hormone (ADH) were measured during body position changes designed to induce blood volume shifts in ten cardiac transplant recipients to assess the contribution of cardiac and vascular volume receptors in the control of ADH secretion. Each subject underwent 15 min of a control period in the seated posture, then assumed a lying posture for 30 min at 6 deg head down tilt (HDT) followed by 20 min of seated recovery. Venous blood samples and cardiac dimensions (echocardiography) were taken at 0 and 15 min before HDT, 5, 15, and 30 min of HDT, and 5, 15, and 30 min of seated recovery. Blood samples were analyzed for hematocrit, plasma osmolality, plasma renin activity (PRA), and ADH. Resting plasma volume (PV) was measured by Evans blue dye and percent changes in PV during posture changes were calculated from changes in hematocrit. Heart rate (HR) and blood pressure (BP) were recorded every 2 min. Results indicate that cardiac volume receptors are not the only mechanism for the control of ADH release during acute blood volume shifts in man.
Mathijssen, Natascha C J; Masereeuw, Rosalinde; Holme, Pal Andre; van Kraaij, Marian G J; Laros-van Gorkom, Britta A P; Peyvandi, Flora; van Heerde, Waander L
2013-08-01
Prophylaxis with plasma-derived or recombinant activated factor VII is beneficial in severe factor VII deficiency. To understand why prophylactic treatment with both products is efficacious, we conducted a pharmacokinetic study. Ten factor VII deficient patients were treated with either recombinant activated (20 μg/kg) or plasma-derived (25 IU/kg) factor VII in a cross-over design. Pharmacokinetic parameters were analyzed through activated factor VII activity, factor VII clotting activity, and factor VII antigen levels on depicted time points. Factor VII activity half-lifes, determined by non-compartmental and one-compartmental analysis (results in brackets), were shorter for recombinant activated (1.4h; 0.7h) than for plasma-derived factor VII (6.8h; 3.2h); both recombinant activated (5.1h; 2.1h and plasma-derived factor VII (5.8h; 3.2h) resulted in longer half-lives of factor VII antigen. Activated factor VII half-lives (based on activated factor VII activity levels) were significantly higher compared to factor VII clotting activity (1.6h; 0.9h). Volumes of distribution were significantly higher for activated factor VII (236 ml/kg; 175 ml/kg, measured by activated factor VII) as compared to plasma-derived factor VII (206 ml/kg; 64 ml/kg, measured by factor FVII activity), suggesting a plasma- and extracellular fluid distribution for recombinant activated factor VII. Recombinant activated factor VII showed significantly shorter half-lifes than plasma-derived factor VII. Volumes of distribution were significantly higher for treatment with recombinant activated factor VII. The longer half-life for plasma-derived factor VII, compared to recombinant activated factor VII, and the increased volume of distribution for recombinant activated factor VII, compared to plasma-derived factor VII may further elucidate the beneficial effect of prophylactic treatment of both products. Copyright © 2013 Elsevier Ltd. All rights reserved.
Membrane-based, sedimentation-assisted plasma separator for point-of-care applications.
Liu, Changchun; Mauk, Michael; Gross, Robert; Bushman, Frederic D; Edelstein, Paul H; Collman, Ronald G; Bau, Haim H
2013-11-05
Often, high-sensitivity, point-of-care (POC) clinical tests, such as HIV viral load, require large volumes of plasma. Although centrifuges are ubiquitously used in clinical laboratories to separate plasma from whole blood, centrifugation is generally inappropriate for on-site testing. Suitable alternatives are not readily available to separate the relatively large volumes of plasma from milliliters of blood that may be needed to meet stringent limit-of-detection specifications for low-abundance target molecules. We report on a simple-to-use, low-cost, pump-free, membrane-based, sedimentation-assisted plasma separator capable of separating a relatively large volume of plasma from undiluted whole blood within minutes. This plasma separator consists of an asymmetric, porous, polysulfone membrane housed in a disposable chamber. The separation process takes advantage of both gravitational sedimentation of blood cells and size exclusion-based filtration. The plasma separator demonstrated a "blood in-plasma out" capability, consistently extracting 275 ± 33.5 μL of plasma from 1.8 mL of undiluted whole blood within less than 7 min. The device was used to separate plasma laden with HIV viruses from HIV virus-spiked whole blood with recovery efficiencies of 95.5% ± 3.5%, 88.0% ± 9.5%, and 81.5% ± 12.1% for viral loads of 35,000, 3500, and 350 copies/mL, respectively. The separation process is self-terminating to prevent excessive hemolysis. The HIV-laden plasma was then injected into our custom-made microfluidic chip for nucleic acid testing and was successfully subjected to reverse-transcriptase loop-mediated isothermal amplification (RT-LAMP), demonstrating that the plasma is sufficiently pure to support high-efficiency nucleic acid amplification.
Membrane-based, sedimentation-assisted plasma separator for point-of-care applications
Liu, Changchun; Mauk, Michael; Gross, Robert; Bushman, Frederic D.; Edelstein, Paul H.; Collman, Ronald G.; Bau, Haim H.
2014-01-01
Often, high sensitivity, point of care, clinical tests, such as HIV viral load, require large volumes of plasma. Although centrifuges are ubiquitously used in clinical laboratories to separate plasma from whole blood, centrifugation is generally inappropriate for on-site testing. Suitable alternatives are not readily available to separate the relatively large volumes of plasma from milliliters of blood that may be needed to meet stringent limit-of-detection specifications for low abundance target molecules. We report on a simple to use, low-cost, pump-free, membrane-based, sedimentation-assisted plasma separator capable of separating a relatively large volume of plasma from undiluted whole blood within minutes. This plasma separator consists of an asymmetric, porous, polysulfone membrane housed in a disposable chamber. The separation process takes advantage of both gravitational sedimentation of blood cells and size exclusion-based filtration. The plasma separator demonstrated a “blood in-plasma out” capability, consistently extracting 275 ±33.5 μL of plasma from 1.8 mL of undiluted whole blood in less than 7 min. The device was used to separate plasma laden with HIV viruses from HIV virus-spiked whole blood with recovery efficiencies of 95.5% ± 3.5%, 88.0% ± 9.5%, and 81.5% ± 12.1% for viral loads of 35,000, 3,500 and 350 copies/mL, respectively. The separation process is self-terminating to prevent excessive hemolysis. The HIV-laden plasma was then injected into our custom-made microfluidic chip for nucleic acid Testing And Was Successfully Subjected To Reverse Transcriptase Loop mediated isothermal amplification (RT-LAMP), demonstrating that the plasma is sufficiently pure to support high efficiency nucleic acid amplification. PMID:24099566
NASA Technical Reports Server (NTRS)
Convertino, V. A.; Benjamin, B. A.; Keil, L. C.; Sandler, H.
1984-01-01
Hemodynamic responses and antidiuretic hormone (ADH) were measured during body position changes, designed to induce central blood volume shifts in ten cardiac and one heart-lung transplant recipients, to assess the contribution of cardiac volume receptors in the control of ADH release during the initial acute phase of exposure to weightlessness. Each subject underwent 15 min of a sitting-control period (C) followed by 30 min of 6 deg headdown tilt (T) and 30 min of resumed sitting (S). Venous blood samples and cardiac dimensions were taken at 0 and 15 min of C; 5, 15, and 30 min of T; and 5, 15, and 30 min of S. Blood samples were analyzed for hematocrit, plasma osmolality, plasma renin activity (PRA), and ADH. Heart rate and blood pressure were recorded every two min. Plasma osmolality was not altered by posture changes. Mean left ventricular end-diastolic volume increased (P less than 0.05) from 90 ml in C to 106 ml in T and returned to 87 ml in S. Plasma ADH was reduced by 20 percent (P less than 0.05) with T, and returned to control levels with S. These responses were similar in six normal cardiac-innervated control subjects. These data may suggest that cardiac volume receptors are not the primary mechanism for the control of ADH release during acute central volume shifts in man.
More, Amar S; Mishra, Jay S; Hankins, Gary D; Kumar, Sathish
2016-08-01
Plasma testosterone levels are elevated in pregnant women with preeclampsia and polycystic ovaries; their offspring are at increased risk for hypertension during adult life. We tested the hypothesis that prenatal testosterone exposure induces dysregulation of the renin-angiotensin-aldosterone system, which is known to play an important role in water and electrolyte balance and blood pressure regulation. Female rats (6 mo old) prenatally exposed to testosterone were examined for adrenal expression of steroidogenic genes, telemetric blood pressure, blood volume and Na(+) and K(+) levels, plasma aldosterone, angiotensin II and vasopressin levels, and vascular responses to angiotensin II and arg(8)-vasopressin. The levels of Cyp11b2 (aldosterone synthase), but not the other adrenal steroidogenic genes, were decreased in testosterone females. Accordingly, plasma aldosterone levels were lower in testosterone females. Plasma volume and serum and urine Na(+) and K(+) levels were not significantly different between control and testosterone females; however, prenatal testosterone exposure significantly increased plasma vasopressin and angiotensin II levels and arterial pressure in adult females. In testosterone females, mesenteric artery contractile responses to angiotensin II were significantly greater, while contractile responses to vasopressin were unaffected. Angiotensin II type-1 receptor expression was increased, while angiotensin II type-2 receptor was decreased in testosterone arteries. These results suggest that prenatal testosterone exposure downregulates adrenal Cyp11b2 expression, leading to decreased plasma aldosterone levels. Elevated angiotensin II and vasopressin levels along with enhanced vascular responsiveness to angiotensin II may serve as an underlying mechanism to maintain plasma volume and Na(+) and K(+) levels and mediate hypertension in adult testosterone females. © 2016 by the Society for the Study of Reproduction, Inc.
Voss, Sven Christian; Robinson, Neil; Alsayrafi, Mohammed; Bourdon, Pitre C; Schumacher, Yorck Olaf; Saugy, Martial; Giraud, Sylvain
2014-06-01
The major objective of this study was to investigate the effects of several days of intense exercise on the growth hormone marker approach to detect doping with human growth hormone (hGH). In addition we investigated the effect of changes in plasma volume on the test. Fifteen male athletes performed a simulated nine-day cycling stage race. Blood samples were collected twice daily over a period of 15 days (stage race + three days before and after). Plasma volumes were estimated by the optimized CO Rebreathing method. IGF-1 and P-III-NP were analyzed by Siemens Immulite and Cisbio Assays, respectively. All measured GH 2000 scores were far below the published decision limits for an adverse analytical finding. The period of exercise did not increase the GH-scores; however the accompanying effect of the increase in Plasma Volume yielded in essentially lower GH-scores. We could demonstrate that a period of heavy, long-term exercise with changes in plasma volume does not interfere with the decision limits for an adverse analytical finding. Copyright © 2014 John Wiley & Sons, Ltd.
Gravitational force and the cardiovascular system
NASA Technical Reports Server (NTRS)
Pendergast, D. R.; Olszowka, A. J.; Rokitka, M. A.; Farhi, L. E.
1991-01-01
Ground-based simulation studies have been conducted to clarify the problems of the cardiovascular adaptation to alterations in gravitational force. Simulated microgravity experiments resulted in increases in cardiac stretch, urine flow, and sodium excretion, which were accompanied by lower plasma renin, aldosterone, and ADH. There appears to be a decrease in plasma volume as well as in sympathetic tone after 2-3 days of 0 Gz. Complete adjustment to 0 Gz is found within 8 h without a decrease in plasma volume, when subjects are allowed to dehydrate mildly.
Inter-conversion of Work and Heat With Plasma Electric Fields
NASA Astrophysics Data System (ADS)
Avinash, K.
2010-11-01
Thermodynamics of a model system where a group of cold charged particles locally confined in a volume VP within a warm plasma of temperature T and fixed volume V (VP<
Plasma 8-iso-Prostaglandin F2α concentrations and outcomes after acute intracerebral hemorrhage.
Du, Quan; Yu, Wen-Hua; Dong, Xiao-Qiao; Yang, Ding-Bo; Shen, Yong-Feng; Wang, Hao; Jiang, Li; Du, Yuan-Feng; Zhang, Zu-Yong; Zhu, Qiang; Che, Zhi-Hao; Liu, Qun-Jie
2014-11-01
Higher plasma 8-iso-Prostaglandin F2α concentrations have been associated with poor outcome of severe traumatic brain injury. We further investigated the relationships between plasma 8-iso-Prostaglandin F2α concentrations and clinical outcomes in patients with acute intracerebral hemorrhage. Plasma 8-iso-Prostaglandin F2α concentrations of 128 consecutive patients and 128 sex- and gender-matched healthy subjects were measured by enzyme-linked immunosorbent assay. We assessed their relationships with disease severity and clinical outcomes including 1-week mortality, 6-month mortality and unfavorable outcome (modified Rankin Scale score>2). Plasma 8-iso-Prostaglandin F2α concentrations were substantially higher in patients than in healthy controls. Plasma 8-iso-Prostaglandin F2α concentrations were positively associated with National Institutes of Health Stroke Scale (NIHSS) scores and hematoma volume using a multivariate linear regression. It emerged as an independent predictor for clinical outcomes of patients using a forward stepwise logistic regression. ROC curves identified the predictive values of plasma 8-iso-Prostaglandin F2α concentrations, and found its predictive value was similar to NIHSS scores and hematoma volumes. However, it just numerically added the predictive values of NIHSS score and hematoma volume. Increased plasma 8-iso-Prostaglandin F2α concentrations are associated with disease severity and clinical outcome after acute intracerebral hemorrhage. Copyright © 2014 Elsevier B.V. All rights reserved.
[Transfusion supply optimization in multiple-discipline surgical hospital].
Solov'eva, I N; Trekova, N A; Krapivkin, I A
2016-01-01
To define optimal variant of transfusion supply of hospital by blood components and to decrease donor blood expense via application of blood preserving technologies. Donor blood components expense, volume of hemotransfusions and their proportion for the period 2012-2014 were analyzed. Number of recipients of packed red cells, fresh-frozen plasma and packed platelets reduced 18.5%, 25% and 80% respectively. Need for donor plasma decreased 35%. Expense of autologous plasma in cardiac surgery was 76% of overall volume. Preoperative plasma sampling is introduced in patients with aortic aneurysm. Number of cardiac interventions performed without donor blood is increased 7-31% depending on its complexity.
Adhesive blood microsampling systems for steroid measurement via LC-MS/MS in the rat.
Heussner, Kirsten; Rauh, Manfred; Cordasic, Nada; Menendez-Castro, Carlos; Huebner, Hanna; Ruebner, Matthias; Schmidt, Marius; Hartner, Andrea; Rascher, Wolfgang; Fahlbusch, Fabian B
2017-04-01
Liquid Chromatography Tandem Mass Spectrometry (LC-MS/MS) allows for the direct analysis of multiple hormones in a single probe with minimal sample volume. Rodent-based animal studies strongly rely on microsampling, such as the dry blood spot (DBS) method. However, DBS suffers the drawback of hematocrit-dependence (non-volumetric). Hence, novel volumetric microsampling techniques were introduced recently, allowing sampling of fixed accurate volumes. We compared these methods for steroid analysis in the rat to improve inter-system comparability. We analyzed steroid levels in blood using the absorptive microsampling devices Whatman® 903 Protein Saver Cards, Noviplex™ Plasma Prep Cards and the Mitra™ Microsampling device and compared the obtained results to the respective EDTA plasma levels. Quantitative steroid analysis was performed via LC-MS/MS. For the determination of the plasma volume factor for each steroid, their levels in pooled blood samples from each human adults and rats (18weeks) were compared and the transferability of these factors was evaluated in a new set of juvenile (21days) and adult (18weeks) rats. Hematocrit was determined concomitantly. Using these approaches, we were unable to apply one single volume factor for each steroid. Instead, plasma volume factors had to be adjusted for the recovery rate of each steroid and device individually. The tested microsampling systems did not allow the use of one single volume factor for adult and juvenile rats based on an unexpectedly strong hematocrit-dependency and other steroid specific (pre-analytic) factors. Our study provides correction factors for LC-MS/MS steroid analysis of volumetric and non-volumetric microsampling systems in comparison to plasma. It argues for thorough analysis of chromatographic effects before the use of novel volumetric systems for steroid analysis. Copyright © 2017 Elsevier Inc. All rights reserved.
Plasma density injection and flow during coaxial helicity injection in a tokamak
NASA Astrophysics Data System (ADS)
Hooper, E. B.
2018-02-01
Whole device, resistive MHD simulations of spheromaks and tokamaks have used a large diffusion coefficient that maintains a nearly constant density throughout the device. In the present work, helicity and plasma are coinjected into a low-density plasma in a tokamak with a small diffusion coefficient. As in previous simulations [Hooper et al., Phys. Plasmas 20, 092510 (2013)], a flux bubble is formed, which expands to fill the tokamak volume. The injected plasma is non-uniform inside the bubble. The flow pattern is analyzed; when the simulation is not axisymmetric, an n = 1 mode on the surface of the bubble generates leakage of plasma into the low-density volume. Closed flux is generated following injection, as in experiments and previous simulations. The result provides a more detailed physics analysis of the injection, including density non-uniformities in the plasma that may affect its use as a startup plasma [Raman et al., Phys. Rev. Lett. 97, 175002 (2006)].
Tokamak experimental power reactor conceptual design. Volume II
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1976-08-01
Volume II contains the following appendices: (1) summary of EPR design parameters, (2) impurity control, (3) plasma computational models, (4) structural support system, (5) materials considerations for the primary energy conversion system, (6) magnetics, (7) neutronics penetration analysis, (8) first wall stress analysis, (9) enrichment of isotopes of hydrogen by cryogenic distillation, and (10) noncircular plasma considerations. (MOW)
Ye, Min; Nagar, Swati; Korzekwa, Ken
2015-01-01
Predicting the pharmacokinetics of highly protein-bound drugs is difficult. Also, since historical plasma protein binding data was often collected using unbuffered plasma, the resulting inaccurate binding data could contribute to incorrect predictions. This study uses a generic physiologically based pharmacokinetic (PBPK) model to predict human plasma concentration-time profiles for 22 highly protein-bound drugs. Tissue distribution was estimated from in vitro drug lipophilicity data, plasma protein binding, and blood: plasma ratio. Clearance was predicted with a well-stirred liver model. Underestimated hepatic clearance for acidic and neutral compounds was corrected by an empirical scaling factor. Predicted values (pharmacokinetic parameters, plasma concentration-time profile) were compared with observed data to evaluate model accuracy. Of the 22 drugs, less than a 2-fold error was obtained for terminal elimination half-life (t1/2, 100% of drugs), peak plasma concentration (Cmax, 100%), area under the plasma concentration-time curve (AUC0–t, 95.4%), clearance (CLh, 95.4%), mean retention time (MRT, 95.4%), and steady state volume (Vss, 90.9%). The impact of fup errors on CLh and Vss prediction was evaluated. Errors in fup resulted in proportional errors in clearance prediction for low-clearance compounds, and in Vss prediction for high-volume neutral drugs. For high-volume basic drugs, errors in fup did not propagate to errors in Vss prediction. This is due to the cancellation of errors in the calculations for tissue partitioning of basic drugs. Overall, plasma profiles were well simulated with the present PBPK model. PMID:26531057
Overview of HIT-SI Results and Plans
NASA Astrophysics Data System (ADS)
Ennis, D. A.; Akcay, C.; Hansen, C. J.; Hicks, N. K.; Hossack, A. C.; Jarboe, T. R.; Marklin, G. J.; Nelson, B. A.; Victor, B. S.
2011-10-01
Experiments in the Helicity Injected Torus-Steady Inductive (HIT-SI) device have achieved record spheromak current amplification during operations in deuterium plasmas. HIT-SI investigates steady inductive helicity injection with the aim of forming and sustaining a high-beta equilibrium in a spheromak geometry using two semi-toroidal injectors. Recent operations in deuterium plasmas have produced toroidal plasma currents greater than 50 kA, with current amplifications (Itor / Iinj) > 3 , and poloidal flux amplifications (ψpol /ψinj) > 10 . High performance deuterium discharges are achieved by initially conditioning the plasma-facing alumina surface of the HIT-SI confinement volume with helium plasmas. During subsequent deuterium operation the alumina surface strongly pumps deuterium, thereby limiting the density in the confinement volume. Additional measurements during high current deuterium discharges demonstrate reduced current and electron density fluctuations, impurity O III ion temperatures up to 50 eV and a toroidal current persistence for 0.6 ms after the injectors are shut off. Progress and plans for the HIT-SI3 configuration, with three injectors mounted on the same side of the confinement volume, will also be presented. Work supported by USDoE and ARRA.
Automated processing of whole blood samples into microliter aliquots of plasma.
Burtis, C A; Johnson, W W; Walker, W A
1988-01-01
A rotor that accepts and automatically processes a bulk aliquot of a single blood sample into multiple aliquots of plasma has been designed and built. The rotor consists of a central processing unit, which includes a disk containing eight precision-bore capillaries. By varying the internal diameters of the capillaries, aliquot volumes ranging 1 to 10 mul can be prepared. In practice, an unmeasured volume of blood is placed in a centre well, and, as the rotor begins to spin, is moved radially into a central annular ring where it is distributed into a series of processing chambers. The rotor is then spun at 3000 rpm for 10 min. When the centrifugal field is removed by slowly decreasing the rotor speed, an aliquot of plasma is withdrawn by capillary action into each of the capillary tubes. The disk containing the eight measured aliquots of plasma is subsequently removed and placed in a modifed rotor for conventional centrifugal analysis. Initial evaluation of the new rotor indicates that it is capable of producing discrete, microliter volumes of plasma with a degree of accuracy and precision approaching that of mechanical pipettes.
Role of atrial natriuretic peptide in systemic responses to acute isotonic volume expansion
NASA Technical Reports Server (NTRS)
Watenpaugh, Donald E.; Yancy, Clyde W.; Buckey, Jay C.; Lane, Lynda D.; Hargens, Alan R.; Blomqvist, C. G.
1992-01-01
A hypothesis is proposed that a temporal relationship exists between increases in cardiac filling pressure and plasma artrial natriuretic peptide (ANP) concentration and also between ANP elevation and vasodilation, fluid movement from plasma to interstitium, and increased urine volume (UV). To test the hypothesis, 30 ml/kg isotonic saline were infused in supine male subjects over 24 min and responses were monitored for 3 h postinfusion. Results show that at end infusion, mean arterial pressure (RAP), heart rate and plasma volume exhibited peak increases of 146, 23, and 27 percent, respectively. Mean plasma ANP and UV peaked (45 and 390 percent, respectively) at 30 min postinfusion. Most cardiovascular variables had returned toward control levels by 1 h postinfusion, and net reabsorption of extravascular fluid ensued. It is concluded that since ANP was not significantly increased until 30 min postinfusion, factors other than ANP initiate responses to intravascular fluid loading. These factors include increased vascular pressures, baroreceptor-mediated vasolidation, and hemodilution of plasma proteins. ANP is suggested to mediate, in part, the renal response to saline infusion.
Tanaka, Hiroyuki; Takano, Kazuhiko; Iijima, Hiroaki; Kubo, Hajime; Maruyama, Nobuko; Hashimoto, Toshio; Arakawa, Kenji; Togo, Masanori; Inagaki, Nobuya; Kaku, Kohei
2017-02-01
Sodium glucose co-transporter 2 (SGLT2) inhibitors exhibit diuretic activity, which is a possible mechanism underlying the cardiovascular benefit of these inhibitors. However, the osmotic diuresis-induced increase in urine volume, and the risk of dehydration have been of concern with SGLT2 inhibitor treatment. This study aimed to investigate the mechanism underlying SGLT2 inhibitor canagliflozin-induced diuresis in Japanese type 2 diabetes mellitus (T2DM) patients. Thirteen T2DM patients received a daily oral dose of 100 mg canagliflozin before breakfast for 6 days. Blood and urine samples were collected at predetermined time points. The primary endpoint was evaluation of correlations between changes from baseline in urine volume and factors that are known to affect urine volume and between actual urine volume and these factors. Canagliflozin transiently increased urine volume and urinary sodium excretion on Day 1 with a return to baseline levels thereafter. Canagliflozin administration increased urinary glucose excretion, which was sustained during repeated-dose administration. Plasma atrial natriuretic peptide (ANP) and N-terminal pro-b-type natriuretic peptide (NT-proBNP) levels decreased, while plasma renin activity increased. On Day 1 of treatment, changes in sodium and potassium excretion were closely correlated with changes in urine output. A post hoc multiple regression analysis showed changes in sodium excretion and water intake as factors that affected urine volume change at Day 1. Furthermore, relative to that at baseline, canagliflozin decreased blood glucose throughout the day and increased plasma total GLP-1 after breakfast. Canagliflozin induced transient sodium excretion and did not induce water intake at Day 1; hence, natriuresis rather than glucose-induced osmotic diuresis may be a major factor involved in the canagliflozin-induced transient increase in urine output. In addition, canagliflozin decreased plasma ANP and NT-proBNP levels and increased plasma renin activity, which may be a compensatory mechanism for sodium retention, leading to subsequent urine output recovery. UMIN000019462. Mitsubishi Tanabe Pharma Corporation.
( sup 99m Tc)diphosphonate uptake and hemodynamics in arthritis of the immature dog knee
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hansen, E.S.; Soballe, K.; Henriksen, T.B.
1991-03-01
The relationship between (99mTc)diphosphonate uptake and bone hemodynamics was studied in canine carrageenan-induced juvenile chronic arthritis. Blood flow was determined with microspheres, plasma and red cell volumes were measured by labeled fibrinogen and red cells, and the microvascular volume and mean transit time of blood were calculated. Normal femoral epiphyses had lower central and higher subchondral blood flow and diphosphonate uptake values. Epiphyseal vascular volume was uniform, resulting in a greater transit time of blood centrally. In arthritis, blood flow and diphosphonate uptake were increased subchondrally and unaffected centrally, while epiphyseal vascular volume was increased throughout, leading to prolonged transitmore » time centrally. The normal metaphyses had low blood flow and diphosphonate uptake values in cancellous bone and very high values in growth plates, but a large vascular volume throughout. The mean transit time therefore was low in growth plates and high in adjacent cancellous bone. Arthritis caused decreased blood flow and diphosphonate uptake in growth plates but increased vascular volume and transit time of blood. Diphosphonate uptake correlated positively with blood flow and plasma volume and negatively with red cell volume in a nonlinear fashion. Thus, changes in diphosphonate uptake and microvascular hemodynamics occur in both epiphyseal and metaphyseal bone in chronic synovitis of the immature knee. The (99mTc)diphosphonate bone scan seems to reflect blood flow, plasma volume, and red cell volume of bone.« less
Tailoring nanocrystalline diamond film properties
Gruen, Dieter M [Downers Grove, IL; McCauley, Thomas G [Somerville, MA; Zhou, Dan [Orlando, FL; Krauss, Alan R [Naperville, IL
2003-07-15
A method for controlling the crystallite size and growth rate of plasma-deposited diamond films. A plasma is established at a pressure in excess of about 55 Torr with controlled concentrations of hydrogen up to about 98% by volume, of unsubstituted hydrocarbons up to about 3% by volume and an inert gas of one or more of the noble gases and nitrogen up to about 98% by volume. The volume ratio of inert gas to hydrogen is preferably maintained at greater than about 4, to deposit a diamond film on a suitable substrate. The diamond film is deposited with a predetermined crystallite size and at a predetermined growth rate.
NASA Astrophysics Data System (ADS)
Cole, Jonathan; Zhang, Yao; Liu, Tianqi; Liu, Chang-jun; Mohan Sankaran, R.
2017-08-01
Scale-up of non-thermal atmospheric-pressure plasma reactors for the synthesis of nanoparticles by homogeneous nucleation is challenging because the active volume is typically reduced to facilitate gas breakdown, enhance discharge stability, and limit particle size and agglomeration, but thus limits throughput. Here, we introduce a dielectric barrier discharge reactor consisting of a coaxial electrode geometry for nanoparticle production that enables a simple scale-up strategy whereby increasing the outer and inner electrode diameters, the plasma volume is increased approximately linearly, while maintaining a sufficiently small electrode gap to maintain the electric field strength. We show with two test reactors that for a given residence time, the nanoparticle production rate increases linearly with volume over a range of precursor concentrations, while having minimal effect on the shape of the particle size distribution. However, our study also reveals that increasing the total gas flow rate in a smaller volume reactor leads to an enhancement of precursor conversion and a comparable production rate to a larger volume reactor. These results suggest that scale-up requires better understanding of the influence of reactor geometry on particle growth dynamics and may not always be a simple function of reactor volume.
Observation of a Relaxed Plasma State in a Quasi-Infinite Cylinder
NASA Astrophysics Data System (ADS)
Gray, T.; Brown, M. R.; Dandurand, D.
2013-02-01
A helical relaxed plasma state is observed in a long cylindrical volume. The cylinder is long enough so that the predicted minimum energy state is a close approximation to the infinite cylinder solution. The plasma is injected at v≥50km/s by a coaxial magnetized plasma gun located at one end of the cylindrical volume. The relaxed state is rapidly attained in 1-2 axial Alfvén times after initiation of the plasma. Magnetic data are favorably compared with an analytical model. Magnetic data exhibit broadband fluctuations of the measured axial modes during the formation period. The broadband activity rapidly decays as the energy condenses into the lowest energy mode, which is in agreement with the minimum energy eigenstate of ∇×B=λB.
Observation of a relaxed plasma state in a quasi-infinite cylinder.
Gray, T; Brown, M R; Dandurand, D
2013-02-22
A helical relaxed plasma state is observed in a long cylindrical volume. The cylinder is long enough so that the predicted minimum energy state is a close approximation to the infinite cylinder solution. The plasma is injected at v ≥ 50 km/s by a coaxial magnetized plasma gun located at one end of the cylindrical volume. The relaxed state is rapidly attained in 1-2 axial Alfvén times after initiation of the plasma. Magnetic data are favorably compared with an analytical model. Magnetic data exhibit broadband fluctuations of the measured axial modes during the formation period. The broadband activity rapidly decays as the energy condenses into the lowest energy mode, which is in agreement with the minimum energy eigenstate of [Symbol: see text] × B = λB.
Blood Volume: Its Adaptation to Endurance Training
NASA Technical Reports Server (NTRS)
Convertino, Victor A.
1991-01-01
Expansion of blood volume (hypervolemia) has been well documented in both cross-sectional and longitudinal studies as a consequence of endurance exercise training. Plasma volume expansion can account for nearly all of the exercise-induced hypervolemia up to 2-4 wk; after this time expansion may be distributed equally between plasma and red cell volumes. The exercise stimulus for hypervolemia has both thermal and nonthermal components that increase total circulating plasma levels of electrolytes and proteins. Although protein and fluid shifts from the extravascular to intravascular space may provide a mechanism for rapid hypervolemia immediately after exercise, evidence supports the notion that chronic hypervolemia associated with exercise training represents a net expansion of total body water and solutes. This net increase of body fluids with exercise training is associated with increased water intake and decreased urine volume output. The mechanism of reduced urine output appears to be increased renal tubular reabsorption of sodium through a more sensitive aldosterone action in man. Exercise training-induced hypervolemia appears to be universal among most animal species, although the mechanisms may be quite different. The hypervolemia may provide advantages of greater body fluid for heat dissipation and thermoregulatory stability as well as larger vascular volume and filling pressure for greater cardiac stroke volume and lower heart rates during exercise.
A new multi-line cusp magnetic field plasma device (MPD) with variable magnetic field
NASA Astrophysics Data System (ADS)
Patel, A. D.; Sharma, M.; Ramasubramanian, N.; Ganesh, R.; Chattopadhyay, P. K.
2018-04-01
A new multi-line cusp magnetic field plasma device consisting of electromagnets with core material has been constructed with a capability to experimentally control the relative volume fractions of magnetized to unmagnetized plasma volume as well as accurate control on the gradient length scales of mean density and temperature profiles. Argon plasma has been produced using a hot tungsten cathode over a wide range of pressures 5 × 10-5 -1 × 10-3 mbar, achieving plasma densities ranging from 109 to 1011 cm-3 and the electron temperature in the range 1-8 eV. The radial profiles of plasma parameters measured along the non-cusp region (in between two consecutive magnets) show a finite region with uniform and quiescent plasma, where the magnetic field is very low such that the ions are unmagnetized. Beyond that region, both plasma species are magnetized and the profiles show gradients both in temperature and density. The electrostatic fluctuation measured using a Langmuir probe radially along the non-cusp region shows less than 1% (δIisat/Iisat < 1%). The plasma thus produced will be used to study new and hitherto unexplored physics parameter space relevant to both laboratory multi-scale plasmas and astrophysical plasmas.
NASA Technical Reports Server (NTRS)
Greenleaf, J. E.; Hinghofer-Szalkay, H.; Roessler, A.; Farrell, P. A.; Loomis, J. L.; Fedele, M. J.; West, J.; Cowell, S. A.; Bowley, Susan M. (Technical Monitor)
2000-01-01
Dissociation between beverage sodium [Na(+)] and osmotic [Osm] concentrations for increasing plasma volume (PV, hypervolemia) appears to refute the high theoretical correlation between plasma [pNa(+)] and [pOsm].
Fluid shifts and endocrine responses during chair rest and water immersion in man
NASA Technical Reports Server (NTRS)
Greenleaf, J. E.; Shvartz, E.; Kravik, S.; Keil, L. C.
1980-01-01
The effects of external water pressure on intercompartmental fluid volume shifts and endocrine responses in man are investigated. Extracellular fluid volumes and plasma and urine electrolyte and endocrine responses of four male subjects were measured during eight hours of head-out water immersion and 16 hours of recovery bed rest and compared to responses obtained during eight hours of chair rest and 16 hours of bed rest without external hydrostatic pressure obtained in the same subjects five months later. Immersion is found to result in a substantial diuresis with respect to chair rest, accounted for by decreases in extracellular volume. A negative water balance during immersion and a positive water balance during chair rest were observed to be accompanied by a shift of extracellular volume to the intracellular compartment, as well as the suppression of plasma arginine vasopressin and renin activities in both regimes. The vasopressin and renin activity decreases are attributed to the increased central blood volume, and half of the plasma loss in immersed subjects is attributed to the effects of external water pressure.
Indocyanine green: A test of hepatic function and a measure of plasma volume in the duck
Patton, J.F.
1978-01-01
1. The exponential removal of ICG from the plasma by the mallard duck liver made possible the measurement of fractional dye clearance (K), plasma volume (PV) and plasma clearance (PC).2. Values obtained for K (14.9%/min), PV (39.2 ml/kg) and PC (5.8 ml/min per kg) agreed with those obtained by other techniques used in a number of species.3. Sex did not affect the removal of ICG by the liver. However, increases in K, PV and PC were noted in hen mallards in laying condition.4. The data should prove useful as baseline values for physiological and pathological studies on the avian liver
21 CFR 864.5950 - Blood volume measuring device.
Code of Federal Regulations, 2011 CFR
2011-04-01
... § 864.5950 Blood volume measuring device. (a) Identification. A blood volume measuring device is a manual, semiautomated, or automated system that is used to calculate the red cell mass, plasma volume... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Blood volume measuring device. 864.5950 Section...
21 CFR 864.5950 - Blood volume measuring device.
Code of Federal Regulations, 2010 CFR
2010-04-01
... § 864.5950 Blood volume measuring device. (a) Identification. A blood volume measuring device is a manual, semiautomated, or automated system that is used to calculate the red cell mass, plasma volume... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Blood volume measuring device. 864.5950 Section...
21 CFR 864.5950 - Blood volume measuring device.
Code of Federal Regulations, 2014 CFR
2014-04-01
... § 864.5950 Blood volume measuring device. (a) Identification. A blood volume measuring device is a manual, semiautomated, or automated system that is used to calculate the red cell mass, plasma volume... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Blood volume measuring device. 864.5950 Section...
21 CFR 864.5950 - Blood volume measuring device.
Code of Federal Regulations, 2013 CFR
2013-04-01
... § 864.5950 Blood volume measuring device. (a) Identification. A blood volume measuring device is a manual, semiautomated, or automated system that is used to calculate the red cell mass, plasma volume... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Blood volume measuring device. 864.5950 Section...
21 CFR 864.5950 - Blood volume measuring device.
Code of Federal Regulations, 2012 CFR
2012-04-01
... § 864.5950 Blood volume measuring device. (a) Identification. A blood volume measuring device is a manual, semiautomated, or automated system that is used to calculate the red cell mass, plasma volume... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Blood volume measuring device. 864.5950 Section...
Allen, Scott; Miller, Kevin C; Albrecht, Jay; Garden-Robinson, Julie; Blodgett-Salafia, Elizabeth
2013-01-01
Adding sodium (Na(+)) to drinks improves rehydration and ad libitum fluid consumption. Clinicians (∼25%) use pickle juice (PJ) to treat cramping. Scientists warn against PJ ingestion, fearing it will cause rapid plasma volume restoration and thereby decrease thirst and delay rehydration. Advice about drinking PJ has been developed but never tested. To determine if drinking small volumes of PJ, hypertonic saline (HS), or deionized water (DIW) affects ad libitum DIW ingestion, plasma variables, or perceptual indicators. Crossover study. Laboratory. Fifteen, euhydrated (urine specific gravity ≤ 1.01) men (age = 22 ± 2 years, height = 178 ± 6 cm, mass = 82.9 ± 8.4 kg). Participants completed 3 testing days (≥ 72 hours between days). After a 30-minute rest, a blood sample was collected. Participants completed 60 minutes of hard exercise (temperature = 36 ± 2°C, relative humidity = 16 ± 1%). Postexercise, they rested for 30 minutes; had a blood sample collected; rated thirst, fullness, and nausea; and ingested 83 ± 8 mL of PJ, HS, or DIW. They rated drink palatability (100-mm visual analog scale) and were allowed to drink DIW ad libitum for 60 minutes. Blood samples and thirst, fullness, and nausea ratings (100-mm visual analog scales) were collected at 15, 30, 45, and 60 minutes posttreatment drink ingestion. Ad libitum DIW volume, percentage change in plasma volume, plasma osmolality (OSMp,) plasma sodium concentration ([Na(+)]p), and thirst, fullness, nausea, and palatability ratings. Participants consumed more DIW ad libitum after HS (708.03 ± 371.03 mL) than after DIW (532.99 ± 337.14 mL, P < .05). Ad libitum DIW ingested after PJ (700.35 ± 366.15 mL) was similar to that after HS and DIW (P > .05). Plasma sodium concentration, OSMp, percentage change in plasma volume, thirst, fullness, and nausea did not differ among treatment drinks over time (P > .05). Deionized water (73 ± 14 mm) was more palatable than HS (17 ± 13 mm) or PJ (26 ± 16 mm, P < .05). The rationale behind advice about drinking PJ is questionable. Participants drank more, not less, after PJ ingestion, and plasma variables and perceptual indicators were similar after PJ and DIW ingestion. Pickle juice did not inhibit short-term rehydration.
A faster running speed is associated with a greater body weight loss in 100-km ultra-marathoners.
Knechtle, Beat; Knechtle, Patrizia; Wirth, Andrea; Alexander Rüst, Christoph; Rosemann, Thomas
2012-01-01
In 219 recreational male runners, we investigated changes in body mass, total body water, haematocrit, plasma sodium concentration ([Na(+)]), and urine specific gravity as well as fluid intake during a 100-km ultra-marathon. The athletes lost 1.9 kg (s = 1.4) of body mass, equal to 2.5% (s = 1.8) of body mass (P < 0.001), 0.7 kg (s = 1.0) of predicted skeletal muscle mass (P < 0.001), 0.2 kg (s = 1.3) of predicted fat mass (P < 0.05), and 0.9 L (s = 1.6) of predicted total body water (P < 0.001). Haematocrit decreased (P < 0.001), urine specific gravity (P < 0.001), plasma volume (P < 0.05), and plasma [Na(+)] (P < 0.05) all increased. Change in body mass was related to running speed (r = -0.16, P < 0.05), change in plasma volume was associated with change in plasma [Na(+)] (r = -0.28, P < 0.0001), and change in body mass was related to both change in plasma [Na(+)] (r = -0.36) and change in plasma volume (r = 0.31) (P < 0.0001). The athletes consumed 0.65 L (s = 0.27) fluid per hour. Fluid intake was related to both running speed (r = 0.42, P < 0.0001) and change in body mass (r = 0.23, P = 0.0006), but not post-race plasma [Na(+)] or change in plasma [Na(+)] (P > 0.05). In conclusion, faster runners lost more body mass, runners lost more body mass when they drank less fluid, and faster runners drank more fluid than slower runners.
Plasma flame for mass purification of contaminated air with chemical and biological warfare agents
NASA Astrophysics Data System (ADS)
Uhm, Han S.; Shin, Dong H.; Hong, Yong C.
2006-09-01
An elimination of airborne simulated chemical and biological warfare agents was carried out by making use of a plasma flame made of atmospheric plasma and a fuel-burning flame, which can purify the interior air of a large volume in isolated spaces such as buildings, public transportation systems, and military vehicles. The plasma flame generator consists of a microwave plasma torch connected in series to a fuel injector and a reaction chamber. For example, a reaction chamber, with the dimensions of a 22cm diameter and 30cm length, purifies an airflow rate of 5000lpm contaminated with toluene (the simulated chemical agent) and soot from a diesel engine (the simulated aerosol for biological agents). Large volumes of purification by the plasma flame will free mankind from the threat of airborne warfare agents. The plasma flame may also effectively purify air that is contaminated with volatile organic compounds, in addition to eliminating soot from diesel engines as an environmental application.
Sheath and bulk expansion induced by RF bias in atmospheric pressure microwave plasma
NASA Astrophysics Data System (ADS)
Lee, Jimo; Nam, Woojin; Lee, Jae Koo; Yun, Gunsu
2017-10-01
A large axial volume expansion of microwave-driven plasma at atmospheric pressure is achieved by applying a low power radio frequency (RF) bias at an axial location well isolated from the original plasma bulk. The evolution of the plasma plume visualized by high speed ICCD imaging suggest that the free electrons drifting toward the bias electrode cause the prodigious expansion of the sheath, creating a stable plasma stream channel between the microwave and the RF electrodes. For argon plasma in ambient air, enhanced emissions of OH and N2 spectral lines are measured in the extended plume region, supporting the acceleration of electrons and subsequent generation of radical species. The coupling of RF bias with microwave provides an efficient way of enlarging the plasma volume and enhancing the production of radicals. Work supported by the National Research Foundation of Korea under BK21+ program and Grant No. 2015R1D1A1A01061556 (Ministry of Education).
Farinas, J; Verkman, A S
1996-12-01
The development of strategies to measure plasma membrane osmotic water permeability (Pf) in epithelial cells has been motivated by the identification of a family of molecular water channels. A general approach utilizing interferometry to measure cell shape and volume was developed and applied to measure Pf in cell layers. The method is based on the cell volume dependence of optical path length (OPL) for a light beam passing through the cell. The small changes in OPL were measured by interferometry. A mathematical model was developed to relate the interference signal to cell volume changes for cells of arbitrary shape and size. To validate the model, a Mach-Zehnder interference microscope was used to image OPL in an Madin Darby Canine Kidney (MDCK) cell layer and to reconstruct the three-dimensional cell shape (OPL resolution < lambda/25). As predicted by the model, a doubling of cell volume resulted in a change in OPL that was proportional to the difference in refractive indices between water and the extracellular medium. The time course of relative cell volume in response to an osmotic gradient was computed from serial interference images. To measure cell volume without microscopy and image analysis, a Mach-Zehnder interferometer was constructed in which one of two interfering laser beams passed through a flow chamber containing the cell layer. The interference signal in response to an osmotic gradient was analyzed to quantify the time course of relative cell volume. The calculated MDCK cell plasma membrane Pf of 6.1 x 10(-4) cm/s at 24 degrees C agreed with that obtained by interference microscopy and by a total internal reflection fluorescence method. Interferometry was also applied to measure the apical plasma membrane water permeability of intact toad urinary bladder; Pf increased fivefold after forskolin stimulation to 0.04 cm/s at 23 degrees C. These results establish and validate the application of interferometry to quantify cell volume and osmotic water permeability in cell layers.
NASA Technical Reports Server (NTRS)
Convertino, V. A.; Engelke, K. A.; Ludwig, D. A.; Doerr, D. F.
1996-01-01
Seven healthy men performed maximal exercise 24 h before the end of 16 days exposure to 6 degrees head-down tilt (HDT) to test the hypothesis that such an exercise technique could restore plasma volume (PV) at the end of a simulated space mission. Exercise consisted of supine cycling with graded work rates increasing by 16 W/min to volitional fatigue and required an average of 16 min. The experimental protocol was a standard cross-over design in which the order of treatment (exercise or control) was counterbalanced across all seven subjects. PV, fluid intake (ad libitum), urine output, renal function, and hormones associated with fluid homeostasis were measured before HDT, 24 h before the end of HDT just prior to exercise, and at the end of HDT 24 h after exercise. HDT reduced PV by 16% in both control and exercise conditions. Maximal exercise completely restored plasma volume within 24 h to 3.9 +/- 3.2% of pre-HDT levels despite continued HDT. Compared with control, exercise induced a 660-ml larger positive fluid balance because of greater fluid intake and reduced urine volume during the 24 h after exercise. These results suggest that one bout of maximal leg exercise before return from 16 days of spaceflight may be completely effective in stimulating thirst and restoring plasma volume to preflight levels.
Hemopoiesis in the pig-tailed monkey Macaca nemestrina during chronic altitude exposure.
NASA Technical Reports Server (NTRS)
Buderer, M. C.; Pace, N.
1972-01-01
Study of monkeys for 180 days at 3800 m altitude to examine their hemopoietic response. Plasma volume was found to be reduced while red cell volume increased steadily for four to five months. Reduction in mean corpuscular hemoglobin content was observed from day 30 to day 120 at altitude. Total plasma protein concentration was unchanged at altitude, but marked reduction in the albumin/globulin ratio occurred. Total circulating plasma protein and albumin were reduced in amount, whereas nonalbumin protein was unchanged. These results imply loss of albumin coupled with a corresponding loss of water from the blood and maintenance of normal plasma osmotic pressure. The body/venous hematocrit ratio was found to be reduced at altitude, possibly as a consequence of the expanded capillary volume of the body. The hemopoietic responses of the pig-tailed monkey at altitude require at least several months for completion, and closely resemble those seen in man; thus, the monkey can serve well for long-term studies of high-altitude acclimatization.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Prakash, Ram; Vyas, Gheesa Lal; Jain, Jalaj
In this paper, the development of large volume double ring Penning plasma discharge source for efficient light emissions is reported. The developed Penning discharge source consists of two cylindrical end cathodes of stainless steel having radius 6 cm and a gap 5.5 cm between them, which are fitted in the top and bottom flanges of the vacuum chamber. Two stainless steel anode rings with thickness 0.4 cm and inner diameters 6.45 cm having separation 2 cm are kept at the discharge centre. Neodymium (Nd{sub 2}Fe{sub 14}B) permanent magnets are physically inserted behind the cathodes for producing nearly uniform magnetic fieldmore » of {approx}0.1 T at the center. Experiments and simulations have been performed for single and double anode ring configurations using helium gas discharge, which infer that double ring configuration gives better light emissions in the large volume Penning plasma discharge arrangement. The optical emission spectroscopy measurements are used to complement the observations. The spectral line-ratio technique is utilized to determine the electron plasma density. The estimated electron plasma density in double ring plasma configuration is {approx}2 Multiplication-Sign 10{sup 11} cm{sup -3}, which is around one order of magnitude larger than that of single ring arrangement.« less
Prakash, Ram; Vyas, Gheesa Lal; Jain, Jalaj; Prajapati, Jitendra; Pal, Udit Narayan; Chowdhuri, Malay Bikas; Manchanda, Ranjana
2012-12-01
In this paper, the development of large volume double ring Penning plasma discharge source for efficient light emissions is reported. The developed Penning discharge source consists of two cylindrical end cathodes of stainless steel having radius 6 cm and a gap 5.5 cm between them, which are fitted in the top and bottom flanges of the vacuum chamber. Two stainless steel anode rings with thickness 0.4 cm and inner diameters 6.45 cm having separation 2 cm are kept at the discharge centre. Neodymium (Nd(2)Fe(14)B) permanent magnets are physically inserted behind the cathodes for producing nearly uniform magnetic field of ~0.1 T at the center. Experiments and simulations have been performed for single and double anode ring configurations using helium gas discharge, which infer that double ring configuration gives better light emissions in the large volume Penning plasma discharge arrangement. The optical emission spectroscopy measurements are used to complement the observations. The spectral line-ratio technique is utilized to determine the electron plasma density. The estimated electron plasma density in double ring plasma configuration is ~2 × 10(11) cm(-3), which is around one order of magnitude larger than that of single ring arrangement.
NASA Astrophysics Data System (ADS)
Vogelaere, P.; Brasseur, M.; Quirion, A.; Leclercq, R.; Laurencelle, L.; Bekaert, S.
1990-03-01
The affect of negative thermal stress on hematological variables at rest, and during submaximal (sub ex) and maximal exercise (max ex) were observed for young males who volunteered in two experimental sessions, performed in cold (0°C) and in normal room temperature (20°C). At rest, hematological variables such as RBC and derivates Hb and Hct were significantly increased ( P<0.05) during cold stress exposure, while plasma volume decreased. The findings of this study suggest that the major factor inducing hypovolemia during low thermal stress can be imputed to local plasma water-shift mechanisms and especially to a transient shift of plasma water from intrato extravascular compartments. Rest values for WBC and platelets (Pla) were also slightly increased during cold stress exposure. However this increase can partly be related to hemoconcentration but also to the cold induced hyperventilation activating the lung circulation. Maximal exhaustive exercise induced, in both experimental temperatures, significant ( P<0.05) increments of RBC, Hb, Hct, and WBC while plasma volume decreased. However, Pla increase was less marked. On the other hand, cold stress raised slightly the observed variations of the different hematological variables. Submaximal exercise induced a similar, though non-significant, pattern for the different hematological variables in both experimental conditions. Observed plasma volume (Δ PV%) reduction appears during exercise. However cold stress induced resting plasma volume variations that are transferred at every exercise level. Neither exercise nor cold inducement significantly modified the hematological indices (MCH, MCV, MCHC). In conclusion hematological variables are affected by cold stress exposure, even when subjects perform a physical activity.
Mengoli, Carlo; Springer, Jan; Bretagne, Stéphane; Cuenca-Estrella, Manuel; Klingspor, Lena; Lagrou, Katrien; Melchers, Willem J. G.; Morton, C. Oliver; Barnes, Rosemary A.; Donnelly, J. Peter; White, P. Lewis
2015-01-01
The use of serum or plasma for Aspergillus PCR testing facilitates automated and standardized technology. Recommendations for serum testing are available, and while serum and plasma are regularly considered interchangeable for use in fungal diagnostics, differences in galactomannan enzyme immunoassay (GM-EIA) performance have been reported and are attributed to clot formation. Therefore, it is important to assess plasma PCR testing to determine if previous recommendations for serum are applicable and also to compare analytical performance with that of serum PCR. Molecular methods testing serum and plasma were compared through multicenter distribution of quality control panels, with additional studies to investigate the effect of clot formation and blood fractionation on DNA availability. Analytical sensitivity and time to positivity (TTP) were compared, and a regression analysis was performed to identify variables that enhanced plasma PCR performance. When testing plasma, sample volume, preextraction-to-postextraction volume ratio, PCR volume, duplicate testing, and the use of an internal control for PCR were positively associated with performance. When whole-blood samples were spiked and then fractionated, the analytical sensitivity and TTP were superior when testing plasma. Centrifugation had no effect on DNA availability, whereas the presence of clot material significantly lowered the concentration (P = 0.028). Technically, there are no major differences in the molecular processing of serum and plasma, but the formation of clot material potentially reduces available DNA in serum. During disease, Aspergillus DNA burdens in blood are often at the limits of PCR performance. Using plasma might improve performance while maintaining the methodological simplicity of serum testing. PMID:26085614
Ye, Min; Nagar, Swati; Korzekwa, Ken
2016-04-01
Predicting the pharmacokinetics of highly protein-bound drugs is difficult. Also, since historical plasma protein binding data were often collected using unbuffered plasma, the resulting inaccurate binding data could contribute to incorrect predictions. This study uses a generic physiologically based pharmacokinetic (PBPK) model to predict human plasma concentration-time profiles for 22 highly protein-bound drugs. Tissue distribution was estimated from in vitro drug lipophilicity data, plasma protein binding and the blood: plasma ratio. Clearance was predicted with a well-stirred liver model. Underestimated hepatic clearance for acidic and neutral compounds was corrected by an empirical scaling factor. Predicted values (pharmacokinetic parameters, plasma concentration-time profile) were compared with observed data to evaluate the model accuracy. Of the 22 drugs, less than a 2-fold error was obtained for the terminal elimination half-life (t1/2 , 100% of drugs), peak plasma concentration (Cmax , 100%), area under the plasma concentration-time curve (AUC0-t , 95.4%), clearance (CLh , 95.4%), mean residence time (MRT, 95.4%) and steady state volume (Vss , 90.9%). The impact of fup errors on CLh and Vss prediction was evaluated. Errors in fup resulted in proportional errors in clearance prediction for low-clearance compounds, and in Vss prediction for high-volume neutral drugs. For high-volume basic drugs, errors in fup did not propagate to errors in Vss prediction. This is due to the cancellation of errors in the calculations for tissue partitioning of basic drugs. Overall, plasma profiles were well simulated with the present PBPK model. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.
Loeffler, Juergen; Mengoli, Carlo; Springer, Jan; Bretagne, Stéphane; Cuenca-Estrella, Manuel; Klingspor, Lena; Lagrou, Katrien; Melchers, Willem J G; Morton, C Oliver; Barnes, Rosemary A; Donnelly, J Peter; White, P Lewis
2015-09-01
The use of serum or plasma for Aspergillus PCR testing facilitates automated and standardized technology. Recommendations for serum testing are available, and while serum and plasma are regularly considered interchangeable for use in fungal diagnostics, differences in galactomannan enzyme immunoassay (GM-EIA) performance have been reported and are attributed to clot formation. Therefore, it is important to assess plasma PCR testing to determine if previous recommendations for serum are applicable and also to compare analytical performance with that of serum PCR. Molecular methods testing serum and plasma were compared through multicenter distribution of quality control panels, with additional studies to investigate the effect of clot formation and blood fractionation on DNA availability. Analytical sensitivity and time to positivity (TTP) were compared, and a regression analysis was performed to identify variables that enhanced plasma PCR performance. When testing plasma, sample volume, preextraction-to-postextraction volume ratio, PCR volume, duplicate testing, and the use of an internal control for PCR were positively associated with performance. When whole-blood samples were spiked and then fractionated, the analytical sensitivity and TTP were superior when testing plasma. Centrifugation had no effect on DNA availability, whereas the presence of clot material significantly lowered the concentration (P = 0.028). Technically, there are no major differences in the molecular processing of serum and plasma, but the formation of clot material potentially reduces available DNA in serum. During disease, Aspergillus DNA burdens in blood are often at the limits of PCR performance. Using plasma might improve performance while maintaining the methodological simplicity of serum testing. Copyright © 2015 Loeffler et al.
Inappropriate Vasopressin Secretion (SIADH) in Burned Patients
1983-03-01
cular route, can promote the secretion of AVP in animals effective arterial volume relative to increased metabolic (24, 28, 29). Plasma renin activity...caloric intake (estimated resting metabolic (ileus or obtundation) were considered separately (Figs. rate, +25%) was begun in the first week. Morphine...further suggest adequate effective volume. for AVP secretion is set at a lower than normal plasma Whether the hypermetabolic state and increased O de
Physiological Responses to Acute Exercise-Heat Stress
1988-01-01
muscle contraction and to dissipate the associated heat release. In hot environments, the core to skin temperature gradient is reduced to skin blood flow needs to be relatively high (compared to cooler environments) to achieve heat transfer sufficient for thermal balance. In addition, sweat secretion can result in a reduced plasma (by dehydration) and thus blood volume. Both high skin blood flow and reduced plasma volume can reduce
Rapid Weight Loss and the Body Fluid Balance and Hemoglobin Mass of Elite Amateur Boxers
Reljic, Dejan; Hässler, Eike; Jost, Joachim; Friedmann-Bette, Birgit
2013-01-01
Context Dehydration is assumed to be a major adverse effect associated with rapid loss of body mass for competing in a lower weight class in combat sports. However, the effects of such weight cutting on body fluid balance in a real-life setting are unknown. Objective To examine the effects of 5% or greater loss of body mass within a few days before competition on body water, blood volume, and plasma volume in elite amateur boxers. Design Case-control study. Setting Sports medicine laboratory. Patients or Other Participants Seventeen male boxers (age = 19.2 ± 2.9 years, height = 175.1 ± 7.0 cm, mass = 65.6 ± 9.2 kg) were assigned to the weight-loss group (WLG; n = 10) or the control group (CON; n = 7). Intervention(s) The WLG reduced body mass by restricting fluid and food and inducing excessive sweat loss by adhering to individual methods. The CON participated in their usual precompetition training. Main Outcome Measure(s) During an ordinary training period (t-1), 2 days before competition (t-2), and 1 week after competition (t-3), we performed bioelectrical impedance measurements; calculated total body water, intracellular water, and extracellular water; and estimated total hemoglobin mass (tHbmass), blood volume, and plasma volume by the CO-rebreathing method. Results In the WLG, the loss of body mass (5.6% ± 1.7%) led to decreases in total body water (6.0% ± 0.9%), extracellular water (12.4% ± 7.6%), tHbmass (5.3% ± 3.8%), blood volume (7.6% ± 2.1%; P < .001), and plasma volume (8.6% ± 3.9%). The intracellular water did not change (P > .05). At t-3, total body water, extracellular water, and plasma volume had returned to near baseline values, but tHbmass and blood volume still were less than baseline values (P < .05). In CON, we found no changes (P > .05). Conclusions In a real-life setting, the loss of approximately 6% body mass within 5 days induced hypohydration, which became evident by the decreases in body water and plasma volume. The reduction in tHbmass was a surprising observation that needs further investigation. PMID:23672332
Atmospheric and Space Sciences: Ionospheres and Plasma Environments
NASA Astrophysics Data System (ADS)
Yiǧit, Erdal
2018-01-01
The SpringerBriefs on Atmospheric and Space Sciences in two volumes presents a concise and interdisciplinary introduction to the basic theory, observation & modeling of atmospheric and ionospheric coupling processes on Earth. The goal is to contribute toward bridging the gap between meteorology, aeronomy, and planetary science. In addition recent progress in several related research topics, such atmospheric wave coupling and variability, is discussed. Volume 1 will focus on the atmosphere, while Volume 2 will present the ionospheres and the plasma environments. Volume 2 is aimed primarily at (research) students and young researchers that would like to gain quick insight into the basics of space sciences and current research. In combination with the first volume, it also is a useful tool for professors who would like to develop a course in atmospheric and space physics.
Le Melledo, Jean Michel; Perez-Parada, Jorge; Morrow, Jarret; Bellavance, Francois; Lara, Nathalie; Jahandar, Farideh; Granger, Robert; Tait, Glendon; McManus, Karen
2011-01-01
Panic disorder has been associated with both an increased risk of coronary events as well as an increased risk of stroke. Hemoconcentration, with both a decrease in plasma volume and an increase in plasma viscosity, is a possible contributor to the risk of acute ischemic events. Our objectives were to demonstrate the process of hemoconcentration in response to induced panic symptoms and to assess the effect of pretreatment with ethinyl estradiol on panic-induced hemoconcentration. Fifteen male patients with panic disorder and 10 male healthy volunteers were included in a double-blind cross-over placebo-controlled design consisting of two injections of pentagastrin following randomized pretreatment with placebo and ethinyl estradiol. Plasma levels of hematocrit and hemoglobin were assessed at baseline and post-injections, and used to calculate an indirect estimation of the change in plasma volume. Pentagastrin-induced panic symptoms were associated with a mean decrease in plasma volume of 4.8% in the placebo pretreatment condition. Pretreatment with ethinyl estradiol attenuated this effect. The acute hemoconcentration observed in relation to pentagastrin-induced panic symptoms may be relevant to the increased risk of stroke and acute coronary events found in patients with panic disorder.
Bourquin, Vincent; Ponte, Belén; Hirschel, Bernard; Pugin, Jérôme; Martin, Pierre-Yves; Saudan, Patrick
2011-01-01
Background. Leptospirosis is a spirochetal zoonosis with complex clinical features including renal and liver failure. Case report. We report the case of a Swiss fisherman presenting with leptospirosis. After initial improvement, refractory septic shock and severe liver and kidney failure developed. The expected mortality was estimated at 90% with clinical scores. The patient underwent plasma exchanges and high-volume hemofiltration (HVHF) with complete recovery of hepatic and kidney functions. Discussion. Plasma exchanges and HVHF may confer survival benefit on patients with severe leptospirosis, refractory septic shock, and multiple-organ failure.
Leypoldt, John K; Akonur, Alp; Agar, Baris U; Culleton, Bruce F
2012-10-01
The kinetics of plasma phosphorus concentrations during hemodialysis (HD) are complex and cannot be described by conventional one- or two-compartment kinetic models. It has recently been shown by others that the physiologic (or apparent distribution) volume for phosphorus (Vr-P) increases with increasing treatment time and shows a large variation among patients treated by thrice weekly and daily HD. Here, we describe the dependence of Vr-P on treatment time and predialysis plasma phosphorus concentration as predicted by a novel pseudo one-compartment model. The kinetics of plasma phosphorus during conventional and six times per week daily HD were simulated as a function of treatment time per session for various dialyzer phosphate clearances and patient-specific phosphorus mobilization clearances (K(M)). Vr-P normalized to extracellular volume from these simulations were reported and compared with previously published empirical findings. Simulated results were relatively independent of dialyzer phosphate clearance and treatment frequency. In contrast, Vr-P was strongly dependent on treatment time per session; the increase in Vr-P with treatment time was larger for higher values of K(M). Vr-P was inversely dependent on predialysis plasma phosphorus concentration. There was significant variation among predicted Vr-P values, depending largely on the value of K(M). We conclude that a pseudo one-compartment model can describe the empirical dependence of the physiologic volume of phosphorus on treatment time and predialysis plasma phosphorus concentration. Further, the variation in physiologic volume of phosphorus among HD patients is largely due to differences in patient-specific phosphorus mobilization clearance. © 2012 The Authors. Hemodialysis International © 2012 International Society for Hemodialysis.
Mechanism of Thirst Attenuation During Head-Out Water Immersion in Men
NASA Technical Reports Server (NTRS)
Wada, F.; Sagawa, S.; Miki, K.; Nagaya, K.; Nakamitsu, S.; Shiraki, K.; Greenleaf, J. E.
1994-01-01
The purpose was to determine whether extracellular volume or osmolality was the major contributing factor for reduction of thirst in air and head-out water immersion in hypohydrated subjects. Eight males (19 - 25 yr) were subjected to thermoneutral immersion and thermoneutral air under two hydration conditions without further drinking: euhydration in water (Eu-H2O) and euhydration in air, and hypohydration in water (Hypo-H2O) and hypohydration in air (3.7% wt loss after exercise in heat). The increased thirst sensation with Hypo-H2O decreased (P less than 0.05) within 10 min of immersion and continued thereafter. Mean plasma osmolality (288 +/- 1 mosmol/kg H2O) and sodium (140 +/- 1 meq/1) remained elevated, and plasma volume increased by 4.2 +/- 1.0% (P less than 0.05) throughout Hypo-H2O. A sustained increase (P less than 0.05) in stroke volume accompanied the prompt and sustained decrease in plasma renin activity and sustained increase (P less than 0.05) in plasma atrial natriuretic peptide during Eu-H2O and Hypo-H2O. Plasma vasopressin decreased from 5.3 +/- 0.7 to 2.9 +/- 0.5 pg/ml (P less than 0.05) during Hypo-H2O but was unchanged in Eu-H2O. These findings suggest a sustained stimulation of the atrial baroreceptors and reduction of a dipsogenic stimulus without major alterations of extracellular osmolality in Hypo-H2O. Thus it appears that vascular volume induced stimuli of cardiopulmonary baroreceptors play a more important role than extracellular osmolality in reducing thirst sensations during immersion in hypohydrated subjects. Thus the purpose for this study was to determine the relative importance of volume and osmotic stimuli, and associated hormonal interaction, for attenuation of thirst during immersion.
Damén, T; Reinsfelt, B; Redfors, B; Nygren, A
2016-05-01
Induction of general anaesthesia has been shown to cause haemodilution and an increase in plasma volume. The aim of this study was to evaluate whether prevention of hypotension during anaesthesia induction could avoid haemodilution. Twenty-four cardiac surgery patients, 66 ± 10 years, were randomised to receive either norepinephrine in a dose needed to maintain mean arterial blood pressure (MAP) at pre-anaesthesia levels after induction or to a control group that received vasopressor if MAP decreased below 60 mmHg. No fluids were infused. Changes in plasma volume were calculated with standard formula: 100 × (Hct(pre)/Hct(post) - 1)/(1 - Hct(pre)). Arterial blood gas was analysed every 10 minutes and non-invasive continuous haemoglobin (SpHb) was continuously measured. Pre-anaesthesia MAP was 98 ± 7 mmHg. Ten minutes after anaesthesia induction, the haematocrit decreased by 5.0 ± 2.5% in the control group compared with 1.2 ± 1.4% in the intervention group, which corresponds to increases in plasma volume by 310 ml and 85 ml respectively. MAP decreased to 69 ± 15 mmHg compared to 92 ± 10 mmHg in the intervention group. The difference maintained throughout the 70 min intervention period. The change in haemoglobin level measured by blood gas analysis could not be detected by SpHb measurement. The mean bias between the SpHb and blood gas haemoglobin was 15 g/l. During anaesthesia induction, haematocrit decreases and plasma volume increases early and parallel to a decrease in blood pressure. This autotransfusion is blunted when blood pressure is maintained at pre-induction levels with norepinephrine. © 2016 The Acta Anaesthesiologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.
Very Large Area/Volume Microwave ECR Plasma and Ion Source
NASA Technical Reports Server (NTRS)
Foster, John E. (Inventor); Patterson, Michael J. (Inventor)
2009-01-01
The present invention is an apparatus and method for producing very large area and large volume plasmas. The invention utilizes electron cyclotron resonances in conjunction with permanent magnets to produce dense, uniform plasmas for long life ion thruster applications or for plasma processing applications such as etching, deposition, ion milling and ion implantation. The large area source is at least five times larger than the 12-inch wafers being processed to date. Its rectangular shape makes it easier to accommodate to materials processing than sources that are circular in shape. The source itself represents the largest ECR ion source built to date. It is electrodeless and does not utilize electromagnets to generate the ECR magnetic circuit, nor does it make use of windows.
A new multi-line cusp magnetic field plasma device (MPD) with variable magnetic field.
Patel, A D; Sharma, M; Ramasubramanian, N; Ganesh, R; Chattopadhyay, P K
2018-04-01
A new multi-line cusp magnetic field plasma device consisting of electromagnets with core material has been constructed with a capability to experimentally control the relative volume fractions of magnetized to unmagnetized plasma volume as well as accurate control on the gradient length scales of mean density and temperature profiles. Argon plasma has been produced using a hot tungsten cathode over a wide range of pressures 5 × 10 -5 -1 × 10 -3 mbar, achieving plasma densities ranging from 10 9 to 10 11 cm -3 and the electron temperature in the range 1-8 eV. The radial profiles of plasma parameters measured along the non-cusp region (in between two consecutive magnets) show a finite region with uniform and quiescent plasma, where the magnetic field is very low such that the ions are unmagnetized. Beyond that region, both plasma species are magnetized and the profiles show gradients both in temperature and density. The electrostatic fluctuation measured using a Langmuir probe radially along the non-cusp region shows less than 1% (δI isat /I isat < 1%). The plasma thus produced will be used to study new and hitherto unexplored physics parameter space relevant to both laboratory multi-scale plasmas and astrophysical plasmas.
Vascular Uptake of Six Rehydration Drinks at Rest and Exercise
NASA Technical Reports Server (NTRS)
Greenleaf, J. E.; Geelen, G.; Jackson, C. G. R.; Saumet, J.-L.; Juhos, L. T.; Keil, L. C.; Fegan-Meyer, D.; Dearborn, A.; Hinghofer-Szalkay, H.; Whittam, J. H.
1996-01-01
A report presents data on the effectiveness of each of six rehydration fluids in restoring total body water and plasma volume in human subjects during rest and exercise. One of the six fluids was water sweetened with aspartame: the others were water containing various amounts of sodium chloride and/or sodium citrate, plus various amounts of aspartame and/or other carbohydrates. In one experiment, five men who had previously dehydrated themselves for 24 hours drank one of the rehydration fluids, then sat for 70 minutes. Pretest plasma volumes were measured and changes in plasma volumes were calculated. This procedure was repeated at weekly intervals until all six rehydration fluids had been tested. Another similar experiment involved four men who exercised on a cycle ergometer for 70 minutes in the supine position after drinking the fluids.
NASA Astrophysics Data System (ADS)
Soloshenko, I. A.; Tsiolko, V. V.; Pogulay, S. S.; Terent'yeva, A. G.; Bazhenov, V. Yu; Shchedrin, A. I.; Ryabtsev, A. V.; Kuzmichev, A. I.
2007-02-01
In this paper the results of theoretical and experimental studies of the component content of active particles formed in a plasma-chemical reactor composed of a multiple-cell generator of active particles, based on volume barrier discharge, and a working chamber are presented. For calculation of the content of uncharged plasma components an approach is proposed which is based on averaging of the power introduced over the entire volume. Advantages of such an approach lie in an absence of fitting parameters, such as the dimensions of microdischarges, their surface density and rate of breakdown. The calculation and the experiment were accomplished with the use of dry air (20% relative humidity) as the plasma generating medium. Concentrations of O3, HNO3, HNO2, N2 O5 and NO3 were measured experimentally in the discharge volume and working chamber for the residence time of particles on a discharge of 0.3 s and more and discharge specific power of 1.5 W cm-3. It has been determined that the best agreement between the calculation and the experiment occurs at calculated gas medium temperatures in the discharge plasma of about 400-425 K, which correspond to the experimentally measured rotational temperature of nitrogen. In most cases the calculated concentrations of O3, HNO3, HNO2, N2O5 and NO3 for the barrier discharge and the working chamber are in fairly good agreement with the respective measured values.
de Haas, S; Ghossein-Doha, C; van Kuijk, S M J; van Drongelen, J; Spaanderman, M E A
2017-02-01
To describe the physiological pattern of gestational plasma volume adjustments in normal singleton pregnancy and compare this with the pattern in pregnancies complicated by pregnancy-induced hypertension, pre-eclampsia or fetal growth restriction. We performed a meta-analysis of the current literature on plasma volume adjustments during physiological and complicated pregnancies. Literature was retrieved from PubMed (NCBI) and EMBASE (Ovid) databases. Included studies reported both reference plasma volume measurements (non-pregnant, prepregnancy or postpartum) and measurements obtained during predetermined gestational ages. Mean differences bet ween the reference and pregnancy plasma volume measurements were calculated for predefined intervals of gestational age using a random-effects model described by DerSimonian and Laird. Thirty studies were included in the meta-analysis with publication dates ranging from 1934 to 2007. Plasma volume increased in the first weeks of pregnancy, with the steepest increase occurring during the second trimester. Plasma volume continued to increase in the third trimester with a pooled maximum increase of 1.13 L (95% CI, 1.07-1.19 L), an increase of 45.6% (95% CI, 43.0-48.1%) in physiological pregnancies compared with the reference value. The plasma volume expansion in gestational hypertensive and growth-restricted pregnancies was 0.80 L (95% CI, 0.59-1.02 L), an increase of 32.3% (95% CI, 23.6-41.1%) in the third trimester, a smaller increase than in physiological pregnancies (P < 0.0001). During physiological pregnancy, plasma volume increases by, on average, more than 1 L as compared with non-pregnant conditions. In pregnancies complicated by pregnancy-induced hypertension, pre-eclampsia or fetal growth restriction, plasma volume increase in the third trimester is 13.3% lower than in normal pregnancy. Copyright © 2016 ISUOG. Published by John Wiley & Sons Ltd. Adaptación fisiológica del volumen del plasma materno durante el embarazo: una revisi\\xF3n sistemática y metaanálisis RESUMEN OBJETIVO: Describir el patrón fisiológico de los cambios en el volumen del plasma gestacional en embarazos normales con feto único y compararlo con el patrón en los embarazos complicados por hipertensión gestacional, preeclampsia o restricción del crecimiento fetal. MÉTODOS: Se realizó un metaanálisis de la literatura actual sobre los cambios en el volumen de plasma durante embarazos complicados y fisiológicos. La literatura se obtuvo de las bases de datos PubMed (NCBI) y EMBASE (Ovid). Los estudios incluidos mencionaban tanto mediciones de referencia del volumen plasmático (no embarazada, antes del embarazo o después del parto) como mediciones tomadas a edades gestacionales predeterminadas. Se calcularon las medias de las diferencias entre las mediciones de referencia y las del embarazo para el volumen plasmático a intervalos predefinidos de la edad gestacional, utilizando un modelo de efectos aleatorios descrito por DerSimonian y Laird. En el metaanálisis se incluyeron treinta estudios con fechas de publicación entre 1934 y 2007. El volumen plasmático aumentó en las primeras semanas de embarazo y el mayor incremento se produjo durante el segundo trimestre. El volumen de plasma continuó aumentando en el tercer trimestre con un aumento combinado máximo de 1,13L (IC 95%, 1,7-1,19 L), lo que supone un aumento del 45,6% (IC 95%, 43,0-48,1%) en embarazos fisiológicas en comparación con el valor de referencia. El aumento del volumen plasmático en los embarazos con hipertensión y con crecimiento intrauterino restringido fue de 0,80L (IC 95%, 0,59-1,02 L), lo que supone un aumento del 32,3% (IC 95%, 23,6-41,1%) en el tercer trimestre, y un incremento menor que en los embarazos fisiológicos (P <0,0001). Durante el embarazo fisiológico el volumen de plasma aumenta, en promedio, más de 1L, en comparación con el de las no embarazadas. En los embarazos complicados por hipertensión gestacional, preeclampsia o restricción del crecimiento fetal, el aumento del volumen plasmático en el tercer trimestre es un 13,3% menor que en el embarazo normal. :meta : ,、。 : meta。PubMed(NCBI)EMBASE(Ovid)。(、)。DerSimonianLaird,。 : Meta30,19342007。,。,1.13 L(95% CI,1.07~1.19 L),,45.6%(95% CI,43.0%~48.1%)。0.80 L(95%CI,0.59~1.02 L),32.3%(95% CI,23.6%~41.1%),(P<0.0001)。 : ,,1 L。、,13.3%。. Copyright © 2016 ISUOG. Published by John Wiley & Sons Ltd.
Continuous monitoring of blood volume changes in humans
NASA Technical Reports Server (NTRS)
Hinghofer-Szalkay, H.; Greenleaf, J. E.
1987-01-01
Use of on-line high-precision mass densitometry for the continuous monitoring of blood volume changes in humans was demonstrated by recording short-term blood volume alterations produced by changes in body position. The mass density of antecubital venous blood was measured continuously for 80 min per session with 0.1 g/l precision at a flow rate of 1.5 ml/min. Additional discrete plasma density and hematocrit measurements gave linear relations between all possible combinations of blood density, plasma density, and hematocrit. Transient filtration phenomena were revealed that are not amenable to discontinuous measurements.
NASA Astrophysics Data System (ADS)
Erofeev, M. V.; Shulepov, M. A.; Ivanov, Yu. F.; Oskomov, K. V.; Tarasenko, V. F.
2016-03-01
Effect of volume discharge plasma initiated by an avalanche electron beam on the composition, structure, and properties of the surface steel layer is investigated. Voltage pulses with incident wave amplitude up to 30 kV, full width at half maximum of about 4 ns, and wave front of about 2.5 ns were applied to the gap with an inhomogeneous electric field. Changes indicating the hardening effect of the volume discharge initiated by an avalanche electron beam are revealed in St3-grade steel specimens treated by the discharge of this type.
1993-09-14
follicular phase of their menstrual cycle as defined as 1 to 11 days post menses . Experimental Protocol Each subject was screened by telephone to...studies exist regarding possible gender differences in plasma volume changes during acute psychological stress. Menstrual cycle effects on physiologic...the different phases of the menstrual cycle (Strauss, Schultheiss, & Cohen, 1983; Carroll , ’I\\lrner I Lee I & Stephenson, 1984). Conflicting
Physical-chemical characterization of the textile dye Azo Ab52 degradation by corona plasma
NASA Astrophysics Data System (ADS)
Gómez, A.; Torres-Arenas, A. J.; Vergara-Sánchez, J.; Torres, C.; Reyes, P. G.; Martínez, H.; Saldarriaga-Noreña, Hugo
2017-10-01
This work characterizes the degradation of the textile dye azo Acid Black 52 by measuring several physical and chemical parameters. A corona plasma was created at atmospheric pressure and applied on the liquid-air interface of water samples containing the dye. 1.0 mM of ferrous sulfate (FeSO4) was added to 1.0 mM dye solution, for a total volume of 250 mL. For each treatment, a number of parameters were quantified. These were voltage, current, temperature, loss of volume, pH, electrical conductivity, concentration, optical mission spectra, chemical oxygen demand (COD), total organic carbon (TOC), and the removal ratio. Because of the increase in the sample temperature, the volume lost by evaporation was explored. The results show that the efficiency of the dye degradation by plasma is a function of treatment time. Moreover, the reactive concentration of FeSO4 and the exposition time of the plasma were varied at a constant volume, leading to the determination of the concentrations and optimal times. Considering the degradation and removal parameters, at the maximum treated time of 80 min, it found that COD was of 96.36%, TOC of 93.93%, and the removal ratio of 97.47%.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Soltanmoradi, Elmira; Shokri, Babak, E-mail: b-shokri@sbu.ac.ir; Laser and Plasma Research Institute, Shahid Beheshti University, G. C., Evin, Tehran 19839-63113
Gigahertz electromagnetic wave scattering from an inhomogeneous collisional plasma layer with bell-like and Epstein electron density distributions is studied by the Green's function volume integral equation method to find the reflectance, transmittance, and absorbance coefficients of this inhomogeneous plasma. Also, the effects of the frequency of the electromagnetic wave, plasma parameters, such as collision frequency, electron density, and plasma thickness, and the effects of the profile of the electron density on the electromagnetic wave scattering from this plasma slab are investigated. According to the results, when the electron density, collision frequency, and plasma thickness are increased, collisional absorbance is enhanced,more » and as a result, the absorbance bandwidth of plasma is broadened. Moreover, this broadening is more evident for plasma with bell-like electron density profile. Also, the bandwidth of the frequency and the range of pressure in which plasma behaves as a good reflector are determined in this article. According to the results, the bandwidth of the frequency is decreased for thicker plasma with bell-like profile, while it does not vary for a different plasma thickness with Epstein profile. Moreover, the range of the pressure is decreased for bell-like profile in comparison with Epstein profile. Furthermore, due to the sharp inhomogeneity of the Epstein profile, the coefficients of plasma that are uniform for plasma with bell-like profile are changed for plasma with Epstein profile, and some perturbations are seen.« less
Møller, J; Jørgensen, J O; Møller, N; Hansen, K W; Pedersen, E B; Christiansen, J S
1991-04-01
Sodium retention and symptoms and signs of fluid retention are commonly recorded during GH administration in both GH-deficient patients and normal subjects. Most reports have however, been casuistic or uncontrolled. In a randomized double blind placebo-controlled cross-over study we therefore examined the effect of 14-day GH administration (12 IU sc at 2000 h) on plasma volume, extracellular volume (ECV), atrial natriuretic peptide (ANP), arginine vasopressin, and the renin angiotensin system in eight healthy adult men. A significant GH induced increase in serum insulin growth factor I was observed. GH caused a significant increase in ECV (L): 20.45 +/- 0.45 (GH), 19.53 +/- 0.48 (placebo) (P less than 0.01), whereas plasma volume (L) remained unchanged 3.92 +/- 0.16 (GH), 4.02 +/- 0.13 (placebo). A significant decrease in plasma ANP (pmol/L) after GH administration was observed: 2.28 +/- 0.54 (GH), 3.16 +/- 0.53 (placebo) P less than 0.01. Plasma aldosterone (pmol/L): 129 +/- 14 (GH), 89 +/- 17 (placebo), P = 0.08, and plasma angiotensin II (pmol/L) levels: 18 +/- 12 (GH), 14 +/- 7 (placebo), P = 0.21, were not significantly elevated. No changes in plasma arginine vasopressin occurred (1.86 +/- 0.05 pmol/L vs. 1.90 +/- 0.05, P = 0.33). Serum sodium and blood pressure remained unaffected. Moderate complaints, which could be ascribed to water retention, were recorded in four subjects [periorbital edema (n = 3), acral paraesthesia (n = 2) and light articular pain (n = 1)]. The symptoms were most pronounced after 2-3 days of treatment and diminished at the end of the period. In summary, 14 days of high dose GH administration caused a significant increase in ECV and a significant suppression of ANP.
Analyzing near infrared scattering from human skin to monitor changes in hematocrit
NASA Astrophysics Data System (ADS)
Chaiken, Joseph; Deng, Bin; Goodisman, Jerry; Shaheen, George; Bussjager, R. J.
2012-01-01
The leading preventable cause of death, world-wide, civilian or military, for all people between the ages of 18-45 is undetected internal hemorrhage. Autonomic compensation mechanisms mask changes such as e.g. hematocrit fluctuations that could give early warning if only they could be monitored continuously with reasonable degrees of precision and relative accuracy. Probing tissue with near infrared radiation (NIR) simultaneously produces remitted fluorescence and Raman scattering (IE) plus Rayleigh/Mie light scattering (EE) that noninvasively give chemical and physical information about the materials and objects within. We model tissue as a three-phase system: plasma and red blood cell (RBC) phases that are mobile and a static tissue phase. In vivo, any volume of tissue naturally experiences spatial and temporal fluctuations of blood plasma and RBC content. Plasma and RBC fractions may be discriminated from each other on the basis of their physical, chemical and optical properties. Thus IE and EE from NIR probing yield information about these fractions. Assuming there is no void volume in viable tissue, or that void volume is constant, changes in plasma and RBC volume fractions may be calculated from simultaneous measurements of the two observables, EE and IE. In a previously published analysis we showed the underlying phenomenology but did not provide an algorithm for calculating volume fractions from experimental data. Here we present a simple analysis that allows continuous monitoring of fluid fraction and hematocrit (Hct) changes by measuring IE and EE, and apply it to some experimental in vivo measurements.
Ion and electron sheath characteristics in a low density and low temperature plasma
NASA Astrophysics Data System (ADS)
Borgohain, Binita; Bailung, H.
2017-11-01
Ion and electron sheath characteristics in a low electron temperature (Te ˜ 0.25-0.40 eV) and density (ne ˜ 106-107 cm-3) plasma are described. The plasma is produced in the experimental volume through diffusion from a hot cathode discharge plasma source by using a magnetic filter. The electron energy distribution function in the experimental plasma volume is measured to be a narrow Maxwellian distribution indicating the absence of primary and energetic electrons which are decoupled in the source side by the cusp magnetic field near the filter. An emissive probe is used to measure the sheath potential profiles in front of a metal plate biased negative and positive with respect to the plasma potential. For a positive plate bias, the electron density decreases considerably and the electron sheath expands with a longer presheath region compared to the ion sheath. The sheath potential structures are found to follow the Debye sheath model.
Neonatal Plasma Transfusion: An Evidence-Based Review.
Keir, Amy K; Stanworth, Simon J
2016-10-01
Several clinical scenarios for plasma transfusion are repeatedly identified in audits, including treatment of bleeding in association with laboratory evidence of coagulopathy, correction of disseminated intravascular coagulation, prevention of intraventricular hemorrhage, management of critically ill neonates (eg, during sepsis or as a volume expander), or correction of markers of prolonged coagulation in the absence of bleeding. The findings of at least one national audit of transfusion practice indicated that almost half of plasma transfusions are given to neonates with abnormal coagulation values with no evidence of active bleeding, despite the limited evidence base to support the effectiveness of this practice. Plasma transfusions to neonates should be considered in the clinical context of bleeding (eg, vitamin K dependent), disseminated intravascular coagulation, and very rare inherited deficiencies of coagulation factors. There seems to be no role for prophylactic plasma to prevent intraventricular hemorrhage or for use as a volume expander. Copyright © 2016 Elsevier Inc. All rights reserved.
Hemodynamics, renal function, plasma renin, and aldosterone in man after 5 to 14 days of bedrest
NASA Technical Reports Server (NTRS)
Melada, G. A.; Goldman, R. H.; Luetscher, J. A.; Zager, P. G.
1975-01-01
Continuous bedrest for 5 to 14 days had no significant effect on resting heart rate, blood pressure, or cardiac output in six normal men. Head-up tilt induced greater tachycardia in 5 of 6 patients after bed rest than in the control period. Propranolol diminished both tachycardia and the incidence of hypotension and faintness in upright posture. Plasma volume fell, extracellular fluid volume increased, and plasma renin activity was significantly elevated following bedrest. Unusually large increases in plasma renin followed head-up tilt or administration of isoproterenol during bedrest and after resuming normal activity. During bedrest, plasma aldosterone was often increased in the early morning. It is concluded that after bedrest, upright posture evokes strong beta-adrenergic activity as well as exaggerated metabolic and circulatory responses which can be reduced or abolished by the beta-adrenergic blocker, propranolol.
Two dimensional radial gas flows in atmospheric pressure plasma-enhanced chemical vapor deposition
NASA Astrophysics Data System (ADS)
Kim, Gwihyun; Park, Seran; Shin, Hyunsu; Song, Seungho; Oh, Hoon-Jung; Ko, Dae Hong; Choi, Jung-Il; Baik, Seung Jae
2017-12-01
Atmospheric pressure (AP) operation of plasma-enhanced chemical vapor deposition (PECVD) is one of promising concepts for high quality and low cost processing. Atmospheric plasma discharge requires narrow gap configuration, which causes an inherent feature of AP PECVD. Two dimensional radial gas flows in AP PECVD induces radial variation of mass-transport and that of substrate temperature. The opposite trend of these variations would be the key consideration in the development of uniform deposition process. Another inherent feature of AP PECVD is confined plasma discharge, from which volume power density concept is derived as a key parameter for the control of deposition rate. We investigated deposition rate as a function of volume power density, gas flux, source gas partial pressure, hydrogen partial pressure, plasma source frequency, and substrate temperature; and derived a design guideline of deposition tool and process development in terms of deposition rate and uniformity.
NASA Astrophysics Data System (ADS)
Soltanmoradi, Elmira; Shokri, Babak
2017-05-01
In this article, the electromagnetic wave scattering from plasma columns with inhomogeneous electron density distribution is studied by the Green's function volume integral equation method. Due to the ready production of such plasmas in the laboratories and their practical application in various technological fields, this study tries to find the effects of plasma parameters such as the electron density, radius, and pressure on the scattering cross-section of a plasma column. Moreover, the incident wave frequency influence of the scattering pattern is demonstrated. Furthermore, the scattering cross-section of a plasma column with an inhomogeneous collision frequency profile is calculated and the effect of this inhomogeneity is discussed first in this article. These results are especially used to determine the appropriate conditions for radar cross-section reduction purposes. It is shown that the radar cross-section of a plasma column reduces more for a larger collision frequency, for a relatively lower plasma frequency, and also for a smaller radius. Furthermore, it is found that the effect of the electron density on the scattering cross-section is more obvious in comparison with the effect of other plasma parameters. Also, the plasma column with homogenous collision frequency can be used as a better shielding in contrast to its inhomogeneous counterpart.
Nanoparticle formation in a low pressure argon/aniline RF plasma
NASA Astrophysics Data System (ADS)
Pattyn, C.; Kovacevic, E.; Hussain, S.; Dias, A.; Lecas, T.; Berndt, J.
2018-01-01
The formation of nanoparticles in low temperature plasmas is of high importance for different fields: from astrophysics to microelectronics. The plasma based synthesis of nanoparticles is a complex multi-scale process that involves a great variety of different species and comprises timescales ranging from milliseconds to several minutes. This contribution focuses on the synthesis of nanoparticles in a low temperature, low pressure capacitively coupled plasma containing mixtures of argon and aniline. Aniline is commonly used for the production of polyaniline, a material that belongs to the family of conductive polymers, which has attracted increasing interest in the last few years due to the large number of potential applications. The nanoparticles which are formed in the plasma volume and levitate there due to the collection of negative charges are investigated in this contribution by means of in-situ FTIR spectroscopy. In addition, the plasma is analyzed by means of plasma (ion) mass spectroscopy. The experiments reveal the possibility to synthesize nanoparticles both in continuous wave and in pulsed discharges. The formation of particles in the plasma volume can be suppressed by pulsing the plasma in a specific frequency range. The in-situ FTIR analysis also reveals the influence of the argon plasma on the characteristics of the nanoparticles.
Walker, Wade T.; Callan, Robert J.; Hill, Ashley E.; Tisher, Kelly B.
2014-01-01
This study evaluated the effects of administering oral powder electrolytes on packed cell volume (PCV), plasma chemistry parameters, and incidence of colic in horses participating on a 6-day 162-km trail ride in which water was not offered ad libitum. Twenty-three horses received grain with powder electrolytes daily while 19 control horses received grain only. Horses were ridden approximately 32 km a day at a walk or trot. Packed cell volume and plasma chemistry parameters were analyzed daily. Episodes of colic were diagnosed and treated by a veterinarian unaware of treatment group allocation. Blood parameters and incidence of colic were compared between treatment groups. Electrolyte administration did not alter PCV or plasma chemistry parameters compared to controls. The incidence of colic was significantly higher in treated horses (P = 0.05). Oral powder electrolytes did not enhance hydration status or electrolyte homeostasis and may be associated with colic in horses participating on long distance trail rides similar to this model. PMID:25082992
Walker, Wade T; Callan, Robert J; Hill, Ashley E; Tisher, Kelly B
2014-08-01
This study evaluated the effects of administering oral powder electrolytes on packed cell volume (PCV), plasma chemistry parameters, and incidence of colic in horses participating on a 6-day 162-km trail ride in which water was not offered ad libitum. Twenty-three horses received grain with powder electrolytes daily while 19 control horses received grain only. Horses were ridden approximately 32 km a day at a walk or trot. Packed cell volume and plasma chemistry parameters were analyzed daily. Episodes of colic were diagnosed and treated by a veterinarian unaware of treatment group allocation. Blood parameters and incidence of colic were compared between treatment groups. Electrolyte administration did not alter PCV or plasma chemistry parameters compared to controls. The incidence of colic was significantly higher in treated horses (P = 0.05). Oral powder electrolytes did not enhance hydration status or electrolyte homeostasis and may be associated with colic in horses participating on long distance trail rides similar to this model.
Computational studies for a multiple-frequency electron cyclotron resonance ion source (abstract)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Alton, G.D.
1996-03-01
The number density of electrons, the energy (electron temperature), and energy distribution are three of the fundamental properties which govern the performance of electron cyclotron resonance (ECR) ion sources in terms of their capability to produce high charge state ions. The maximum electron energy is affected by several processes including the ability of the plasma to absorb power. In principle, the performances of an ECR ion source can be realized by increasing the physical size of the ECR zone in relation to the total plasma volume. The ECR zones can be increased either in the spatial or frequency domains inmore » any ECR ion source based on B-minimum plasma confinement principles. The former technique requires the design of a carefully tailored magnetic field geometry so that the central region of the plasma volume is a large, uniformly distributed plasma volume which surrounds the axis of symmetry, as proposed in Ref. . Present art forms of the ECR source utilize single frequency microwave power supplies to maintain the plasma discharge; because the magnetic field distribution continually changes in this source design, the ECR zones are relegated to thin {open_quote}{open_quote}surfaces{close_quote}{close_quote} which surround the axis of symmetry. As a consequence of the small ECR zone in relation to the total plasma volume, the probability for stochastic heating of the electrons is quite low, thereby compromising the source performance. This handicap can be overcome by use of broadband, multiple frequency microwave power as evidenced by the enhanced performances of the CAPRICE and AECR ion sources when two frequency microwave power was utilized. We have used particle-in-cell codes to simulate the magnetic field distributions in these sources and to demonstrate the advantages of using multiple, discrete frequencies over single frequencies to power conventional ECR ion sources. (Abstract Truncated)« less
Simultaneous Determination of Fluid Shifts during Thermal Stress in a Small Animal Model,
1985-09-01
extracellular fluid voitmie (BCF) was measured using a single injection c- inulin , technique, and plasma voilme (PV) was determined by ca.rdio--yreen dye...using tritiated water, extracell1ular fluid volume (ECF) was measured using a single injection C- inulin technique, and plasma volume (PV) was...space. However, inulin (10) has several advantages over the aforementioned because it Is not metabolized, stored, or incorporated by cells or
Plasma Volume during Heat Stress and Exercise in Women,
1986-11-01
in the osmoregulation of vasopressin during the luteal phase may not be adequate to explain the lower plasma volume that was observed in this study...P.H., B.A. Spruce, 3. Burd (1985) Osmoregulation of vasopressin secretion during the menstrual cycle. -In: Schrier, R.W. (ed) Vasopressin, Raven... osmoregulation of arginine vasopressin during the human menstrual cycle. Clin Endocrinol 22: 37-42 23. Stephenson LA, Kolka MA, Gonzalez RR (1984) Circadian and
Effect of Increased Plasma Osmolality on Cold-Induced Thirst Attenuation
2008-08-01
Xuid intake. Oropharyngeal and gastric stim- uli, as well as blood volume and plasma osmolality (Posm) are important factors modifying thirst (Greenleaf...reported to result in an increase in the osmotic thresh- old for the stimulation of thirst due to an increase in central blood volume (Sobocinska and...model 5877, Abbott Hospital, Inc., Chicago, IL, USA) was inserted into the catheter port for acquisition of subsequent blood samples. The catheter
Farinas, J; Verkman, A S
1996-01-01
The development of strategies to measure plasma membrane osmotic water permeability (Pf) in epithelial cells has been motivated by the identification of a family of molecular water channels. A general approach utilizing interferometry to measure cell shape and volume was developed and applied to measure Pf in cell layers. The method is based on the cell volume dependence of optical path length (OPL) for a light beam passing through the cell. The small changes in OPL were measured by interferometry. A mathematical model was developed to relate the interference signal to cell volume changes for cells of arbitrary shape and size. To validate the model, a Mach-Zehnder interference microscope was used to image OPL in an Madin Darby Canine Kidney (MDCK) cell layer and to reconstruct the three-dimensional cell shape (OPL resolution < lambda/25). As predicted by the model, a doubling of cell volume resulted in a change in OPL that was proportional to the difference in refractive indices between water and the extracellular medium. The time course of relative cell volume in response to an osmotic gradient was computed from serial interference images. To measure cell volume without microscopy and image analysis, a Mach-Zehnder interferometer was constructed in which one of two interfering laser beams passed through a flow chamber containing the cell layer. The interference signal in response to an osmotic gradient was analyzed to quantify the time course of relative cell volume. The calculated MDCK cell plasma membrane Pf of 6.1 x 10(-4) cm/s at 24 degrees C agreed with that obtained by interference microscopy and by a total internal reflection fluorescence method. Interferometry was also applied to measure the apical plasma membrane water permeability of intact toad urinary bladder; Pf increased fivefold after forskolin stimulation to 0.04 cm/s at 23 degrees C. These results establish and validate the application of interferometry to quantify cell volume and osmotic water permeability in cell layers. Images FIGURE 1 FIGURE 2 FIGURE 3 FIGURE 4 FIGURE 6 PMID:8968620
Large-Volume Resonant Microwave Discharge for Plasma Cleaning of a CEBAF 5-Cell SRF Cavity
DOE Office of Scientific and Technical Information (OSTI.GOV)
J. Mammosser, S. Ahmed, K. Macha, J. Upadhyay, M. Nikoli, S. Popovi, L. Vuakovi
2012-07-01
We report the preliminary results on plasma generation in a 5-cell CEBAF superconducting radio-frequency (SRF) cavity for the application of cavity interior surface cleaning. CEBAF currently has {approx}300 of these five cell cavities installed in the Jefferson Lab accelerator which are mostly limited by cavity surface contamination. The development of an in-situ cavity surface cleaning method utilizing a resonant microwave discharge could lead to significant CEBAF accelerator performance improvement. This microwave discharge is currently being used for the development of a set of plasma cleaning procedures targeted to the removal of various organic, metal and metal oxide impurities. These contaminantsmore » are responsible for the increase of surface resistance and the reduction of RF performance in installed cavities. The CEBAF five cell cavity volume is {approx} 0.5 m2, which places the discharge in the category of large-volume plasmas. CEBAF cavity has a cylindrical symmetry, but its elliptical shape and transversal power coupling makes it an unusual plasma application, which requires special consideration of microwave breakdown. Our preliminary study includes microwave breakdown and optical spectroscopy, which was used to define the operating pressure range and the rate of removal of organic impurities.« less
Code of Federal Regulations, 2010 CFR
2010-04-01
... STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Source Plasma § 640.72 Records. (a) In addition to the... § 640.74(b)(2) are being met for Source Plasma intended for manufacture into injectable products. (2... volume or weight of plasma withdrawn from a donor need not be kept on the individual donor record...
Code of Federal Regulations, 2012 CFR
2012-04-01
... STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Source Plasma § 640.72 Records. (a) In addition to the... § 640.74(b)(2) are being met for Source Plasma intended for manufacture into injectable products. (2... volume or weight of plasma withdrawn from a donor need not be kept on the individual donor record...
Code of Federal Regulations, 2011 CFR
2011-04-01
... STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Source Plasma § 640.72 Records. (a) In addition to the... § 640.74(b)(2) are being met for Source Plasma intended for manufacture into injectable products. (2... volume or weight of plasma withdrawn from a donor need not be kept on the individual donor record...
Code of Federal Regulations, 2013 CFR
2013-04-01
... STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Source Plasma § 640.72 Records. (a) In addition to the... § 640.74(b)(2) are being met for Source Plasma intended for manufacture into injectable products. (2... volume or weight of plasma withdrawn from a donor need not be kept on the individual donor record...
Code of Federal Regulations, 2014 CFR
2014-04-01
... STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Source Plasma § 640.72 Records. (a) In addition to the... § 640.74(b)(2) are being met for Source Plasma intended for manufacture into injectable products. (2... volume or weight of plasma withdrawn from a donor need not be kept on the individual donor record...
Therapeutic plasma exchange: a paired comparison of Fresenius AS104 vs. COBE Spectra.
Burgstaler, E A; Pineda, A A
2001-01-01
For therapeutic plasma exchange (TPE), continuous flow separators are known to be efficient as exemplified by Fresenius AS104 and COBE Spectra. The AS104 uses an interface monitoring system in the centrifuge during TPE, whereas Spectra uses computer algorithms to establish the plasma-cell interface. To determine the plasma collection efficiency (PLCE), anticoagulant (AC) volumes used, and platelets (PLT) lost of the AS104 and the Spectra, we performed a prospective paired comparison of 20 TPE (each machine). The study included 17 patients, 1.3 plasma volume exchanges (without AC), equal inlet rates, and AC ratio of 13:1. Processing times did not include reinfuse mode. Platelet loss was determined by sampling the collection bags. Inlet rates were between 60-110 ml/min. Diagnosis included peripheral neuropathies, TTP and cryoglobulinemia. The AS104 had significantly (P<0.0001) lower average whole blood processed (F:6,601 vs. S:8,584 ml), AC volume (F:532 vs. S:719 ml), and processing time (F:80 vs. S:102 minutes) than Spectra. The AS104 had significantly (P<0.0001) higher average plasma flow rates (F:53 vs. S:44 ml/minute), plasma collection efficiency (F:90 vs. S:69%), and platelet loss (F:2.0 vs. S:0.14 x 10(11) plt) than Spectra. Platelet loss correlated with inlet flow rate with the AS104 but not with the Spectra. The AS104 has a significantly higher collection efficiency than Spectra allowing it to remove the same amount of plasma in significantly less time, by processing significantly less blood, using significantly less AC, but removing significantly more platelets than Spectra. Copyright 2001 Wiley-Liss, Inc.
Mechanism of thirst attenuation during head-out water immersion in men
NASA Technical Reports Server (NTRS)
Wada, F.; Sagawa, S.; Miki, K.; Nagaya, K.; Nakamitsu, S.; Shiraki, K.; Greenleaf, J. E.
1995-01-01
The purpose was to determine whether extracellular volume or osmolality was the major contributing factor for reduction of thirst in air and head-out water immersion in hypohydrated subjects. Eight males (19-25 yr) were subjected to thermoneutral immersion and thermoneutral air under two hydration conditions without further drinking: euhydration in water (Eu-H2O) and euhydration in air, and hypohydration in water (Hypo-H2O) and hypohydration in air (3.7% wt loss after exercise in heat). The increased thirst sensation with Hypo-H2O decreased (P < 0.05) within 10 min of immersion and continued thereafter. Mean plasma osmolality (288 +/- 1 mosmol/kgH2O) and sodium (140 +/- 1 meq/l) remained elevated, and plasma volume increased by 4.2 +/- 1.0% (P < 0.05) throughout Hypo-H2O. A sustained increase (P < 0.05) in stroke volume accompanied the prompt and sustained decrease in plasma renin activity and sustained increase (P < 0.05) in plasma atrial natriuretic peptide during Eu-H2O and Hypo-H2O. Plasma vasopressin decreased from 5.3 +/- 0.7 to 2.9 +/- 0.5 pg/ml (P < 0.05) during Hypo-H2O but was unchanged in Eu-H2O. These findings suggest a sustained stimulation of the atrial baroreceptors and reduction of a dipsogenic stimulus without major alterations of extracellular osmolality in Hypo-H2O. Thus it appears that vascular volume-induced stimuli of cardiopulmonary baroreceptors play a more important role than extracellular osmolality in reducing thirst sensations during immersion in hypohydrated subjects.
Mayer, R B; Ebner, T; Yaman, C; Hartl, J; Sir, A; Krain, V; Oppelt, P; Shebl, O
2015-02-01
To investigate the effect of intracervical and intravaginal application of seminal plasma on the endometrium, as assessed by endometrial/subendometrial vascularization and endometrial volume between the day of oocyte retrieval and the day of embryo transfer in an in-vitro fertilization/intracytoplasmic sperm injection (IVF/ICSI) cycle. This was a double-blind, placebo-controlled, randomized study including patients undergoing a first or second IVF/ICSI cycle. Homologous seminal plasma or placebo (sodium chloride) was injected into the cervix and posterior vaginal fornix just after follicle aspiration. Three-dimensional power Doppler examination was performed 30 min before oocyte retrieval and 30 min before embryo transfer. Main outcome measures were changes in vascularization flow index (VFI), flow index (FI) and vascularization index (VI) of the endometrium/subendometrium using VOCAL™ (Virtual Organ Computer-aided AnaLysis) and endometrial volume. One hundred patients agreed to participate in the study. Twenty-three patients were excluded, mainly as a result of canceled embryo transfer. Data were analyzed from 40 patients receiving seminal plasma and 37 receiving placebo. No significant differences between the two groups were seen in VFI, FI or VI of the endometrium or subendometrium or in endometrial volume on the day of oocyte pick-up and on the day of embryo transfer. Neither endometrial/subendometrial vascularization parameters nor endometrial volume seem to be affected by the application of seminal plasma in patients undergoing their first or second IVF/ICSI cycle. Copyright © 2014 ISUOG. Published by John Wiley & Sons Ltd.
The pathogenesis of hypertension: black-white differences.
Blaustein, M P; Grim, C E
1991-01-01
In summary, for reasons that are not clear, some persons seem to be extremely good at retaining sodium on a high-sodium diet or poor at excreting sodium on a high-sodium intake. This is more frequent in Western hemisphere blacks than in whites in the West or in blacks in Africa. These geographic/ethnic differences in sodium handling ability may be related to environmental factors or, more likely, to inherited differences in the ability to conserve sodium based on the evolutionary principle of survival fo the fittest for the ability to conserve sodium. The frequency of this salt-conserving (thrifty) genotype in Western hemisphere blacks may have been further increased as a consequence of severe selection pressures for survival based on the ability to conserve sodium during the slavery period of history in the West. One characteristic of the blood pressure control systems of Western hemisphere blacks is suppression of plasma renin activity without suppression of aldosterone production. In addition there is greater nephrosclerosis in blacks than whites and a more rapid decline in creatinine clearance with age. When more sodium is ingested than the kidneys are able to handle (excrete), there is a (transient) slight positive sodium balance; as a result sodium, chloride, and water are retained, resulting in an expansion of plasma volume (Fig. 7-3). The initial physiologic responses include (increased) secretion of atrial natriuretic peptides and the digitalis-like substance (natriuretic hormone), and inhibition of vasopressin and aldosterone secretion. The net effect is directly enhanced natriuresis and diuresis, and a reduction in plasma volume, with no significant effect on blood pressure. However, if there is a continuing tendency to sodium retention and volume expansion, the capacity of the aforementioned mechanisms to control plasma volume will be exceeded; then, the chronically elevated level of the digitalis-like substance will inhibit the sodium pumps in the arterial and venous smooth muscle cells and in the sympathetic neurons. The increased venous tone will help to reduce plasma volume directly by reducing central venous volume. Arterial tone will be increased by direct action of the digitalis-like substance on the arterial smooth muscle and, indirectly, via the hormone's action on the sympathetic neurons. Initially, of course, blood pressure will be maintained in the normal range (but will be labile) because of the compensating cardiovascular reflexes. Once the capacity of these reflexes to control blood pressure is exceeded, however, the blood pressure will begin to rise; this will induce a pressure natriuresis to help restore plasma volume to normal.(ABSTRACT TRUNCATED AT 400 WORDS)
Mehr, Chelsea R; Gupta, Rajan; von Recklinghausen, Friedrich M; Szczepiorkowski, Zbigniew M; Dunbar, Nancy M
2013-06-01
Transfusion of plasma and red blood cell (RBC) units in a balanced ratio approximating 1:1 has been shown in retrospective studies to be associated with improved outcomes for trauma patients. Our low-volume rural trauma center uses a trauma-activated transfusion algorithm. Plasma is thawed upon activation to avoid wastage. However, the time required for plasma thawing has made achievement of a 1:1 ratio early in resuscitation challenging. In this study, the time required for plasma thawing is characterized, and a potential solution is proposed. A retrospective chart study of 38 moderately and massively transfused (≥6 U in the first 24 hours) trauma patients admitted from January 2008 to March 2012 was performed. We evaluated the time required to dispense plasma and the number of RBCs dispensed before plasma in these patients. The average time between the dispense of RBCs and plasma was 26 minutes (median, 28; range, 0-48 minutes). The average number of RBCs dispensed before plasma was 8 U (median, 7 U; range, 0-24 U). Nearly one third of massively transfused patients had 10 RBCs or greater dispensed before plasma was available. There exists the potential for delayed plasma availability owing to time required for thawing, which may compromise the ability to provide balanced plasma to RBC transfusion to trauma patients. Maintenance of a thawed Group AB plasma inventory may not be operationally feasible for rural centers with low trauma volumes. Use of a thawed Group A plasma inventory is a potential alternative to ensure rapid plasma availability. Therapeutic study, level V.
United States Air Force Summer Research Program -- 1993. Volume 7. Armstrong Laboratory
1993-12-01
formulation, absorption, plasma binding affinity, biomembrane barriers, and relative extraction by the specific organ of the body concerned with...simultaneously administered or a drug may "interact" with itself. The concomitant administration of phenobarbital and warfarin results in lower plasma ... plasma protein which binds to basic lipophilic drugs including propranolol, meperidine, quinidine, and chlorpromazine. If a variation in the plasma
Bed-rest studies: Fluid and electrolyte responses
NASA Technical Reports Server (NTRS)
Greenleaf, J. E.
1983-01-01
Confinement in the horizontal position for 2 to 3 weeks results in a chronic decrease in plasma volume, increased interstitial fluid volume, and unchanged or slightly increased extracellular fluid volume. Concentrations of blood electrolytes, glucose, and nitrogenous constituents remain within normal limits of variability when maintenance levels of isometric or isotonic exercise are performed for 1 hr/day. Hematocrit and plasma osmolality can be elevated significantly throughout bed rest (BR). Significant diuresis occurs on the first day, and increases in urine Na and Ca continue throughout BR, although voluntary fluid intake is unchanged. Urine Na and K are evaluated during the second week of BR in spite of stabilization of PV and extracellular volume. The initial diuresis probably arises from the extracellular fluid while subsequent urine loss above control levels must come from the intracellular fluid. Preservation of the extracellular volume takes precedance over maintenance of the intracellular fluid volume. The functioning of a natriuretic factor (hormone) to account for the continued increased loss of Na in the urine is suggested.
1992-05-06
Robert Valeri, Linda E. Pivacek, Hiliary Siebens, and Mark D. Altschule ». PERFORMING ORGANIZATION NAME AND AOORESS Naval Blood Research Laboratory...Gibson JG, Peacock WC, Seligman AM, Sack T: Circulating red cell volume measured simultaneously by the radioactive iron and dye methods. J Clin
Code of Federal Regulations, 2010 CFR
2010-04-01
... one unit of blood and resuspended in an appropriate volume of original plasma, as prescribed in § 640.24(d). (b) Source. The source material for Platelets is plasma which may be obtained by whole blood...
Code of Federal Regulations, 2012 CFR
2012-04-01
... one unit of blood and resuspended in an appropriate volume of original plasma, as prescribed in § 640.24(d). (b) Source. The source material for Platelets is plasma which may be obtained by whole blood...
Code of Federal Regulations, 2011 CFR
2011-04-01
... one unit of blood and resuspended in an appropriate volume of original plasma, as prescribed in § 640.24(d). (b) Source. The source material for Platelets is plasma which may be obtained by whole blood...
Code of Federal Regulations, 2013 CFR
2013-04-01
... one unit of blood and resuspended in an appropriate volume of original plasma, as prescribed in § 640.24(d). (b) Source. The source material for Platelets is plasma which may be obtained by whole blood...
Code of Federal Regulations, 2014 CFR
2014-04-01
... one unit of blood and resuspended in an appropriate volume of original plasma, as prescribed in § 640.24(d). (b) Source. The source material for Platelets is plasma which may be obtained by whole blood...
Cabo, Rona; Kozik, Karolina; Milanowski, Maciej; Hernes, Sigrunn; Slettan, Audun; Haugen, Margaretha; Ye, Shu; Blomhoff, Rune; Mansoor, M Azam
2014-06-10
Low concentration of plasma pyridoxal-5-phosphate (PLP) is associated with hyperhomocysteinemia and inflammation. Most methods for the measurement of plasma PLP require large specimen volume and involve the use of toxic reagents. We have developed a HPLC method for the measurement of PLP and 4-pyridoxic acid (4-PA) in plasma, which requires small specimen volume. The samples are prepared without adding any toxic reagents. Furthermore, we have examined whether intake of vitamin B6 affects the concentration of plasma PLP and 4-PA. The coefficient of variation of the method was 6% and the recovery of the added vitamin in plasma was about 100%. The concentrations of plasma PLP and 4-PA in 168 healthy subjects were 40.6 (8.4-165.0) nmol/L, median and (range) and 17.5 (3.7-114.79) nmol/L, median and (range) respectively. In the multiple regression analyses, the concentration of plasma PLP was associated with the concentration of plasma 4-PA (p<0.0001), BMI, (p=0.02) and sex, (p=0.0008). The concentration of plasma 4-PA was associated with plasma PLP (p<0.0001), serum folate (p=0.004), smoking (p=0.03) and vitamin B6 intake (p=0.01). The present method is suitable for large clinical studies for the measurement of plasma PLP and 4-PA. Our findings demonstrate that plasma 4-PA, BMI and sex are the major determinants of plasma PLP in healthy individuals. Copyright © 2014 Elsevier B.V. All rights reserved.
2007-02-28
of magnitude in size. Also unlike corona -like devices such as the plasma needle , which generates 2-3 mm long plasma at the tip of a sharp wire...Distribution Unlimited Table of Contents Abstract AC System with Water Electrode Current voltage characteristics Plasma diagnostics results Experimental setup...Laroussi, PI. 4 AC SYSTEM WITH WATER ELECTRODE Recently, non-equilibrium atmospheric pressure plasmas have been used in a variety of material processing
Immunoglobulin G levels during collection of large volume plasma for fractionation.
Burkhardt, Thomas; Rothe, Remo; Moog, Rainer
2017-06-01
There is a need of comprehensive work dealing with the quality of plasma for fractionation with respect to the IgG content as today most plasma derivates are used to treat patients with immunodeficiencies and autoimmune disorders. Therefore, a prospective study was carried out to analyse IgG levels before plasmapheresis and every 200ml collected plasma. Fifty-four experienced plasmapheresis donors were recruited for subsequent 850ml plasmapheresis using the Aurora Plasmapheresis System. Donorś peripheral blood counts were analysed before and after plasmapheresis using an electronic counter. Total protein, IgG and citrate were measured turbidometrically before, during and after apheresis as well as in the plasma product. Furthermore, platelets, red and white blood cells were analysed as parameters of product quality. An average of 2751±247ml blood was processed in 47±6min. The collected plasma volume was 850±1mL and citrate consumption was 177±15mL. A continuous drop of donors' IgG level was observed during plasmapheresis. The drop was 13% of the IgG baseline value at 800mL collected plasma. Total protein, IgG and cell counts of the plasma product met current guidelines of plasma for fractionation. Donors' IgG levels during apheresis showed a steady decrease without compromising the quality of plasma product. Copyright © 2017 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Wimmer, C.; Schiesko, L.; Fantz, U.
2016-02-01
BATMAN (Bavarian Test Machine for Negative ions) is a test facility equipped with a 1/8 scale H- source for the ITER heating neutral beam injection. Several diagnostics in the boundary layer close to the plasma grid (first grid of the accelerator system) followed the transition from volume to surface dominated H- production starting with a Cs-free, cleaned source and subsequent evaporation of caesium, while the source has been operated at ITER relevant pressure of 0.3 Pa: Langmuir probes are used to determine the plasma potential, optical emission spectroscopy is used to follow the caesiation process, and cavity ring-down spectroscopy allows for the measurement of the H- density. The influence on the plasma during the transition from an electron-ion plasma towards an ion-ion plasma, in which negative hydrogen ions become the dominant negatively charged particle species, is seen in a strong increase of the H- density combined with a reduction of the plasma potential. A clear correlation of the extracted current densities (jH-, je) exists with the Cs emission.
Wimmer, C; Schiesko, L; Fantz, U
2016-02-01
BATMAN (Bavarian Test Machine for Negative ions) is a test facility equipped with a 18 scale H(-) source for the ITER heating neutral beam injection. Several diagnostics in the boundary layer close to the plasma grid (first grid of the accelerator system) followed the transition from volume to surface dominated H(-) production starting with a Cs-free, cleaned source and subsequent evaporation of caesium, while the source has been operated at ITER relevant pressure of 0.3 Pa: Langmuir probes are used to determine the plasma potential, optical emission spectroscopy is used to follow the caesiation process, and cavity ring-down spectroscopy allows for the measurement of the H(-) density. The influence on the plasma during the transition from an electron-ion plasma towards an ion-ion plasma, in which negative hydrogen ions become the dominant negatively charged particle species, is seen in a strong increase of the H(-) density combined with a reduction of the plasma potential. A clear correlation of the extracted current densities (j(H(-)), j(e)) exists with the Cs emission.
The relationship between uric acid and potassium in normal subjects.
Kennedy, A C; Boddy, K; King, P C; Brennan, J; Anderson, J A; Buchanan, W W
1978-01-01
The serum uric acid concentration in normal healthy subjects has been studied in relation to sex, height, weight, lean body mass measured from total body potassium and predicted from the Hume-Weyers formula (1971), total body potassium, plasma potassium and urea, and packed cell volume. The strongest correlation was found with sex, but height, weight, total body potassium, lean body mass (measured and predicted) also correlated significantly with serum uric acid concentration. However, when the sex variable was removed, the other factors lost their significant correlation. Finally, total red blood cell and plasma volumes were predicted (Hume and Goldberg, 1964) and from these an estimate of total plasma uric acid, total plasma potassium, and total red blood cell potassium obtained. Measured total body potassium was found to correlate well with total plasma potassium and total red blood cell potassium independent of sex. Total plasma uric acid correlated well with measured total body potassium when both sexes were considered and when separated into male and female groups the males retained a significant correlation as did the female group. PMID:686865
Opoku-Okrah, Clement; Sam, Daniel Kwasi; Nkum, Bernard; Dogbe, Elliot Eli; Antwi-Boateng, Lilian; Sackey, Benedict; Gyamfi, Daniel; Danquah, Kwabena Owusu
2016-01-01
Introduction Sports anaemia is a physiological activity that occurs amongst footballers and may be due to poor diet, over-training, as well as an increase in plasma volume in endurance training activities. High plasma volume leads to changes in haematological parameters that may impact on endurance of footballers. The objective of the study was to determine the correlation between haematological and an-thropometric indices and their role in sports anaemia in a tropical setting. Methods Venous blood was taken into EDTA for 12 soccer players of KNUST soccer team before training and after training for the first (W1) and fifth (W5) weeks of training sessions. Complete blood count analysis was done for each blood sample and anthropometric parameters such as height, weight, body mass index, body fat percent and lean body mass were also measured. Cross-tabulations with mean and standard deviation or median and range were computed. Paired t-test & and Mann-Whitney test for parametric and non-parametric data computations were carried out and a p-value ≤ 0.05 was taken to rep-resent significant difference between data groups. Results There was significant reduction in haemoglobin (p = 0.003), haematocrit (p = 0.002), mean cell volume (MCV) (p = 0.034) and red blood cell (RBC) count (p = 0.011) as a result of a significant expansion of plasma volume (p= 0.006). Neutrophil, lymphocyte and eosinophil counts were reduced significantly (p= 0.043, 0.001 and 0.007, respectively) after the training at W5. Lean body mass (LBM) inversely correlated with haemoglobin (r = -0.787, p = 0.002) and haematocrit (r = -0.588, p = 0.044). Body fat percentage (BFP) also negatively correlated with lymphocyte count (r = -0.700, p = 0.011). Furthermore, there was a positive correlation between body mass index (BMI) and plasma volume change after the training programme (r = 0.689, p = 0.013). Conclusion The results suggest that sports anaemia was induced by an increase in plasma volume that resulted in changes in haematological parameters. PMID:27583089
Opoku-Okrah, Clement; Sam, Daniel Kwasi; Nkum, Bernard; Dogbe, Elliot Eli; Antwi-Boateng, Lilian; Sackey, Benedict; Gyamfi, Daniel; Danquah, Kwabena Owusu
2016-01-01
Sports anaemia is a physiological activity that occurs amongst footballers and may be due to poor diet, over-training, as well as an increase in plasma volume in endurance training activities. High plasma volume leads to changes in haematological parameters that may impact on endurance of footballers. The objective of the study was to determine the correlation between haematological and an-thropometric indices and their role in sports anaemia in a tropical setting. Venous blood was taken into EDTA for 12 soccer players of KNUST soccer team before training and after training for the first (W1) and fifth (W5) weeks of training sessions. Complete blood count analysis was done for each blood sample and anthropometric parameters such as height, weight, body mass index, body fat percent and lean body mass were also measured. Cross-tabulations with mean and standard deviation or median and range were computed. Paired t-test & and Mann-Whitney test for parametric and non-parametric data computations were carried out and a p-value ≤ 0.05 was taken to rep-resent significant difference between data groups. There was significant reduction in haemoglobin (p = 0.003), haematocrit (p = 0.002), mean cell volume (MCV) (p = 0.034) and red blood cell (RBC) count (p = 0.011) as a result of a significant expansion of plasma volume (p= 0.006). Neutrophil, lymphocyte and eosinophil counts were reduced significantly (p= 0.043, 0.001 and 0.007, respectively) after the training at W5. Lean body mass (LBM) inversely correlated with haemoglobin (r = -0.787, p = 0.002) and haematocrit (r = -0.588, p = 0.044). Body fat percentage (BFP) also negatively correlated with lymphocyte count (r = -0.700, p = 0.011). Furthermore, there was a positive correlation between body mass index (BMI) and plasma volume change after the training programme (r = 0.689, p = 0.013). The results suggest that sports anaemia was induced by an increase in plasma volume that resulted in changes in haematological parameters.
A review of direct experimental measurements of detachment
Boedo, J.; McLean, A. G.; Rudakov, D. L.; ...
2018-02-22
Detached divertor plasmas feature strong radial and parallel gradients of density, temperature, electric fields and flow over the divertor volume and therefore, sampling the divertor plasma directly provides crucial knowledge to the interpretation and modeling efforts. Here, we review the contribution of diagnostics that directly sample the plasma to the advancement of knowledge of the physics of detachment and detached divertors, such as the characteristics of the various regimes, discovery and quantification of drifts and identification of convection of heat and particles. We focus on wall probes, scanning probes, retarding field analyzers and Thomson Scattering (TS) in the divertor regionmore » and also include the contribution of measurements away from the divertor that provide insight on how divertor detachment affects core, edge or pedestal conditions. Wall probes are critical as they can be installed in closed volumes of difficult access to other diagnostics and measure plasma parameters at the divertor structures, which define the plasma boundary conditions and where detachment effects are more likely to be strongest.« less
A review of direct experimental measurements of detachment
DOE Office of Scientific and Technical Information (OSTI.GOV)
Boedo, J.; McLean, A. G.; Rudakov, D. L.
Detached divertor plasmas feature strong radial and parallel gradients of density, temperature, electric fields and flow over the divertor volume and therefore, sampling the divertor plasma directly provides crucial knowledge to the interpretation and modeling efforts. Here, we review the contribution of diagnostics that directly sample the plasma to the advancement of knowledge of the physics of detachment and detached divertors, such as the characteristics of the various regimes, discovery and quantification of drifts and identification of convection of heat and particles. We focus on wall probes, scanning probes, retarding field analyzers and Thomson Scattering (TS) in the divertor regionmore » and also include the contribution of measurements away from the divertor that provide insight on how divertor detachment affects core, edge or pedestal conditions. Wall probes are critical as they can be installed in closed volumes of difficult access to other diagnostics and measure plasma parameters at the divertor structures, which define the plasma boundary conditions and where detachment effects are more likely to be strongest.« less
Incorporation of an Energy Equation into a Pulsed Inductive Thruster Performance Model
NASA Technical Reports Server (NTRS)
Polzin, Kurt A.; Reneau, Jarred P.; Sankaran, Kameshwaran
2011-01-01
A model for pulsed inductive plasma acceleration containing an energy equation to account for the various sources and sinks in such devices is presented. The model consists of a set of circuit equations coupled to an equation of motion and energy equation for the plasma. The latter two equations are obtained for the plasma current sheet by treating it as a one-element finite volume, integrating the equations over that volume, and then matching known terms or quantities already calculated in the model to the resulting current sheet-averaged terms in the equations. Calculations showing the time-evolution of the various sources and sinks in the system are presented to demonstrate the efficacy of the model, with two separate resistivity models employed to show an example of how the plasma transport properties can affect the calculation. While neither resistivity model is fully accurate, the demonstration shows that it is possible within this modeling framework to time-accurately update various plasma parameters.
Plasma /Na+/, /Ca++/, and volume shifts and thermoregulation during exercise in man
NASA Technical Reports Server (NTRS)
Greenleaf, J. E.; Convertino, V. A.; Stremel, R. W.; Bernauer, E. M.; Adams, W. C.; Vignau, S. R.; Brock, P. J.
1977-01-01
Graded-exercise experiments are conducted on six trained male runners (19-23 yr) subjected to ergometer exercise in a program consisting of 30-min resting control period, 60 min of rest or exercise at work loads that resulted in a maximal oxygen uptake equivalent to 6% (resting), 23%, 43%, and 62% of maximal oxygen uptake, followed by 30 min of recovery. The parameters measured and discussed are rectal temperature (T-re), skin temperatures at different spots, maximal oxygen uptake, plasma volume (PV), and various plasma electrolyte and protein concentrations. The objectives are to determine whether the increased T-re during progressively greater work loads are related to plasma sodium ion and calcium ion concentrations, as well as to evaluate the influence of PV shifts on the electrolyte and osmotic concentrations. The results suggest that the shift (loss) in PV accounts for the increases in the plasma constituent concentrations that result in significant correlations with T-re.
A review of direct experimental measurements of detachment
NASA Astrophysics Data System (ADS)
Boedo, J.; McLean, A. G.; Rudakov, D. L.; Watkins, J. G.
2018-04-01
Detached divertor plasmas feature strong radial and parallel gradients of density, temperature, electric fields and flow over the divertor volume and therefore, sampling the divertor plasma directly provides crucial knowledge to the interpretation and modeling efforts. We review the contribution of diagnostics that directly sample the plasma to the advancement of knowledge of the physics of detachment and detached divertors, such as the characteristics of the various regimes, discovery and quantification of drifts and identification of convection of heat and particles. We focus on wall probes, scanning probes, retarding field analyzers and Thomson scattering in the divertor region and also include the contribution of measurements away from the divertor that provide insight on how divertor detachment affects core, edge or pedestal conditions. Wall probes are critical as they can be installed in closed volumes of difficult access to other diagnostics and measure plasma parameters at the divertor structures, which define the plasma boundary conditions and where detachment effects are more likely to be strongest.
NASA Astrophysics Data System (ADS)
Parali, Levent; Kurbanov, Mirza A.; Bayramov, Azad A.; Tatardar, Farida N.; Sultanakhmedova, Ramazanova I.; Xanlar, Huseynova Gulnara
2015-11-01
High-density polymer composites with semiconductor or dielectric fillers such as aluminum nitride (AIN), aluminum oxide (Al2O3), titanium carbide (TiC), titanium nitride (TiN), boron nitride (BN), silicon nitride (Si3N4), and titanium carbonitride (TiCN) were prepared by the hot pressing method. Each powder phase of the composites was exposed to an electric discharge plasma process before composite formation. The effects of the electric discharge plasma process and the filler content (volume fraction) on the thermal conductivity, volt-ampere characteristics, thermally stimulated depolarization current, as well as electrical and mechanical strength were investigated. The results of the study indicate that, with increasing filler volume fraction, the thermal conductivity of the samples also increased. Furthermore, the thermal conductivity, and electrophysical and mechanical properties of the high-density polyethylene + 70% BN composite modified using the electric discharge plasma showed improvement when compared with that without electric discharge plasma treatment.
Connolly, Luke J; Nordsborg, Nikolai B; Nyberg, Michael; Weihe, Pál; Krustrup, Peter; Mohr, Magni
2016-10-01
We tested the hypothesis that low-volume high-intensity swimming has a larger impact on insulin sensitivity and glucose control than high-volume low-intensity swimming in inactive premenopausal women with mild hypertension. Sixty-two untrained premenopausal women were randomised to an inactive control (n = 20; CON), a high-intensity low-volume (n = 21; HIT) or a low-intensity high-volume (n = 21; LIT) training group. During the 15-week intervention period, HIT performed 3 weekly 6-10 × 30-s all-out swimming intervals (average heart rate (HR) = 86 ± 3 % HRmax) interspersed by 2-min recovery periods and LIT swam continuously for 1 h at low intensity (average HR = 73 ± 3 % HRmax). Fasting blood samples were taken and an oral glucose tolerance test (OGTT) was conducted pre- and post-intervention. After HIT, resting plasma [insulin] was lowered (17 ± 34 %; P < 0.05) but remained similar after LIT and CON. Following HIT, 60-min OGTT plasma [insulin] and [glucose] was lowered (24 ± 30 % and 10 ± 16 %; P < 0.05) but remained similar after LIT and CON. Total area under the curve for plasma [glucose] was lower (P < 0.05) after HIT than LIT (660 ± 141 vs. 860 ± 325 mmol min L(-1)). Insulin sensitivity (HOMA-IR) had increased (P < 0.05) by 22 ± 34 % after HIT, with no significant change after LIT or CON, respectively. Plasma soluble intracellular cell adhesion molecule 1 was lowered (P < 0.05) by 4 ± 8 and 3 ± 9 % after HIT and CON, respectively, while plasma soluble vascular cell adhesion molecule 1 had decreased (P < 0.05) by 8 ± 23 % after HIT only. These findings suggest that low-volume high-intensity intermittent swimming is an effective and time-efficient training strategy for improving insulin sensitivity, glucose control and biomarkers of vascular function in inactive, middle-aged mildly hypertensive women.
Noninductively Driven Tokamak Plasmas at Near-Unity Toroidal Beta
Schlossberg, David J.; Bodner, Grant M.; Bongard, Michael W.; ...
2017-07-01
Access to and characterization of sustained, toroidally confined plasmas with a very high plasma-to-magnetic pressure ratio (β t), low internal inductance, high elongation, and nonsolenoidal current drive is a central goal of present tokamak plasma research. Stable access to this desirable parameter space is demonstrated in plasmas with ultralow aspect ratio and high elongation. Local helicity injection provides nonsolenoidal sustainment, low internal inductance, and ion heating. Equilibrium analyses indicate β t up to ~100% with a minimum |B| well spanning up to ~50% of the plasma volume.
Noninductively Driven Tokamak Plasmas at Near-Unity Toroidal Beta.
Schlossberg, D J; Bodner, G M; Bongard, M W; Burke, M G; Fonck, R J; Perry, J M; Reusch, J A
2017-07-21
Access to and characterization of sustained, toroidally confined plasmas with a very high plasma-to-magnetic pressure ratio (β_{t}), low internal inductance, high elongation, and nonsolenoidal current drive is a central goal of present tokamak plasma research. Stable access to this desirable parameter space is demonstrated in plasmas with ultralow aspect ratio and high elongation. Local helicity injection provides nonsolenoidal sustainment, low internal inductance, and ion heating. Equilibrium analyses indicate β_{t} up to ∼100% with a minimum |B| well spanning up to ∼50% of the plasma volume.
Impact of ABO-Identical vs ABO-Compatible Nonidentical Plasma Transfusion in Trauma Patients
2010-09-01
and B patients in turn could receive AB donor plasma. Few studies have examined the im- pact of compatible nonidentical plasma transfusion . In platelet ... transfusion ,19 the administration of compatible nonidenti- cal platelets to patients undergoing coro- nary artery bypass grafting or valve re...significantly different (in boldface) and for the volume of packed red blood cells, plasma, platelets , cryoprecipitate, and factor VIIa transfused . cBecause
APPARATUS FOR MINIMIZING ENERGY LOSSES FROM MAGNETICALLY CONFINED VOLUMES OF HOT PLASMA
Post, R.F.
1961-10-01
An apparatus is described for controlling electron temperature in plasma confined in a Pyrotron magnetic containment field. Basically the device comprises means for directing low temperature electrons to the plasma in controlled quantities to maintain a predetermined optimum equilibrium electron temperature whereat minimum losses of plasma ions due to ambipolar effects and energy damping of the ions due to dynamical friction with the electrons occur. (AEC)
Annular vortex merging processes in non-neutral electron plasmas
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kaga, Chikato, E-mail: d146073@hiroshima-u.ac.jp; Ito, Kiyokazu; Higaki, Hiroyuki
2015-06-29
Non-neutral electron plasmas in a uniform magnetic field are investigated experimentally as a two dimensional (2D) fluid. Previously, it was reported that 2D phase space volume increases during a vortex merging process with viscosity. However, the measurement was restricted to a plasma with a high density. Here, an alternative method is introduced to evaluate a similar process for a plasma with a low density.
NASA Astrophysics Data System (ADS)
Jiang, Weiman; Tang, Jie; Wang, Yishan; Zhao, Wei; Duan, Yixiang
2014-09-01
A direct-current-driven plasma jet is developed by applying a longitudinal electric field on the flowing argon at ambient air. This plasma shows a torch shape with its cross-section increased from the anode to the cathode. Comparison with its counterparts indicates that the gas flow plays a key role in variation of the plasma structure and contributes much to enlarging the plasma volume. It is also found that the circular hollow metal base promotes generation of plasma with a high-power volume density in a limited space. The optical emission spectroscopy (OES) diagnosis indicates that the plasma comprises many reactive species, such as OH, O, excited N2, and Ar metastables. Examination of the rotational and vibrational temperature indicates that the plasma is under nonequilibrium condition and the excited species OH(A 2Σ+), O(5P), and N2(C 3Πu) are partly generated by energy transfer from argon metastables. The spatially resolved OES of plasma reveals that the negative glow, Faraday dark space, and positive column are distributed across the gas gap. The absence of the anode glow is attributed to the fact that many electrons in the vicinity of the anode follow ions into the positive column due to the ambipolar diffusion in the flowing gas.
Molecular Diagnostics of Fusion and Laboratory Plasmas
NASA Astrophysics Data System (ADS)
Fantz, U.
2005-05-01
The presence of molecules in the cold scrape-off layer of fusion experiments and industrial plasmas requires an understanding of the molecular dynamics in these low temperature plasmas. Suitable diagnostic methods can provide an insight in molecular processes in the plasma volume as well as for plasma surface interactions. A very simple but powerful technique is the molecular emission spectroscopy. Spectra are obtained easily, whereas interpretation might be very complex and relies on the availability of atomic and molecular data. Examples are given for hydrogen plasmas and plasmas with hydrocarbons which both are of importance in industrial applications as well as in fusion experiments.
Significant increase in salivary substance p level after a single oral dose of cevimeline in humans.
Suzuki, Yosuke; Itoh, Hiroki; Amada, Kohei; Yamamura, Ryota; Sato, Yuhki; Takeyama, Masaharu
2013-01-01
Cevimeline is a novel muscarinic acetylcholine receptor agonist currently being developed as a therapeutic agent for xerostomia. We examined the effects of cevimeline on salivary and plasma levels of substance-P- (SP-), calcitonin-gene-related-peptide- (CGRP-), and vasoactive-intestinal-polypeptide- (VIP-) like immunoreactive substances (ISs) in humans. An open-labeled crossover study was conducted on seven healthy volunteers. Saliva volume was measured, and saliva and venous blood samples were collected before and 30-240 min after a single oral dose of cevimeline or placebo. Salivary and plasma levels of SP-, CGRP-, and VIP-IS were measured using a highly sensitive enzyme immunoassay. A single oral dose of cevimeline resulted in significant increases in salivary but not plasma SP-IS level compared to placebo. Cevimeline administration did not alter the salivary or plasma levels of CGRP-IS or VIP-IS compared to placebo. Significant increases in salivary volume were observed after cevimeline administration compared to placebo. A significant correlation was observed between the total release of SP-IS and that of salivary volume. These findings suggest an association of SP with the enhancement of salivary secretion by cevimeline.
Significant Increase in Salivary Substance P Level after a Single Oral Dose of Cevimeline in Humans
Suzuki, Yosuke; Itoh, Hiroki; Amada, Kohei; Yamamura, Ryota; Sato, Yuhki; Takeyama, Masaharu
2013-01-01
Cevimeline is a novel muscarinic acetylcholine receptor agonist currently being developed as a therapeutic agent for xerostomia. We examined the effects of cevimeline on salivary and plasma levels of substance-P- (SP-), calcitonin-gene-related-peptide- (CGRP-), and vasoactive-intestinal-polypeptide- (VIP-) like immunoreactive substances (ISs) in humans. An open-labeled crossover study was conducted on seven healthy volunteers. Saliva volume was measured, and saliva and venous blood samples were collected before and 30–240 min after a single oral dose of cevimeline or placebo. Salivary and plasma levels of SP-, CGRP-, and VIP-IS were measured using a highly sensitive enzyme immunoassay. A single oral dose of cevimeline resulted in significant increases in salivary but not plasma SP-IS level compared to placebo. Cevimeline administration did not alter the salivary or plasma levels of CGRP-IS or VIP-IS compared to placebo. Significant increases in salivary volume were observed after cevimeline administration compared to placebo. A significant correlation was observed between the total release of SP-IS and that of salivary volume. These findings suggest an association of SP with the enhancement of salivary secretion by cevimeline. PMID:23589717
Saito, Koichi; Ohmura, Atsuko; Takekuma, Mikiko; Sasano, Ryoichi; Matsuki, Yasuhiko; Nakazawa, Hiroyuki
2007-06-01
A newly developed large-volume injection (LVI) technique that employs a unique stomach-shaped inlet liner (SSIL) inside of a programmable temperature vaporizer was used for the determination of trace amounts of dioxins in human milk and plasma. The initial temperature and the initial dwelling time of the inlet and the kind of solvent used were found to be critical in determining the analytical sensitivity of dioxins due to the loss of these relatively volatile compounds during solvent vaporization. Human milk and plasma were purified and fractionated by pre-packed multi-layered silica-gel chromatography and activated carbon silica-gel column chromatography. A 20-microL aliquot of the fraction collected from the chromatography with toluene was directly applied to the LVI system in high-resolution gas chromatography/high-resolution mass spectrometry. Excellent correlation (r > 0.97) between the values obtained by the LVI method using the SSIL device and those by the conventional regular-volume splitless injection method was obtained for PCDDs, PCDFs and non-ortho PCBs in human milk and plasma samples.
The mechanism of the increase in glomerular filtration rate in the twelve-day pregnant rat.
Baylis, C
1980-01-01
1. Whole kidney and micropuncture techniques were employed to investigate the determinants of glomerular ultrafiltration in virgin and 12-day pregnant rats. 2. A significant increase in whole kidney glomerular filtration rate (g.f.r.) and superficial cortical single nephron g.f.r. was noted in pregnant rats compared to virgins. 3. Increases in whole kidney and glomerular plasma flow rate also occurred in pregnancy which were in proportion to the increase in rate of filtration. No differences were noted in the hydrostatic and oncotic pressures which influence formation of glomerular ultrafiltrate in the superficial nephron population. 4. Reduction in arterial haematocrit and no change in mean red cell volume indicate that a plasma volume expansion has occurred by day 12 of pregnancy in the rat. 5. It is concluded that the increased g.f.r. seen in 12-day pregnant rats is exclusively the result of an increase in renal plasma flow rate (r.p.f.) since the other determinants of glomerular ultrafiltration are unaffected by pregnancy. The plasma volume expansion which also occurs must be, at least in part, responsible for the increase in r.p.f. PMID:7441561
Investigations of microwave plasmas - Applications in electrothermal thruster systems
NASA Technical Reports Server (NTRS)
Haraburda, Scott S.; Hawley, Martin C.
1989-01-01
Experimental studies which have been conducted to develop understanding of plasma processes used for spacecraft propulsion are reviewed. The techniques discussed are calorimetry and volume measurements using the TM 011 and TM 012 modes in the microwave cavity system. The use of plasmas in electrical propulsion and microwave induction is reviewed. Plasma containment, microwave power production, energy distribution, and the pressure and flow dependence of the energy distribution are addressed. The plasma dimensions and their dependence on pressure, flow, and power are considered.
Investigations of microwave plasmas - Applications in electrothermal thruster systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Haraburda, S.S.; Hawley, M.C.
1989-01-01
Experimental studies which have been conducted to develop understanding of plasma processes used for spacecraft propulsion are reviewed. The techniques discussed are calorimetry and volume measurements using the TM 011 and TM 012 modes in the microwave cavity system. The use of plasmas in electrical propulsion and microwave induction is reviewed. Plasma containment, microwave power production, energy distribution, and the pressure and flow dependence of the energy distribution are addressed. The plasma dimensions and their dependence on pressure, flow, and power are considered. 10 refs.
Montero, D; Rauber, S; Goetze, J P; Lundby, C
2016-10-01
Erythropoiesis is a tightly controlled biological event, but its regulation under non-hypoxic conditions, however, remains unresolved. We examined whether acute changes in central venous blood pressure (CVP) elicited by whole-body tilting affect erythropoietin (EPO) concentration according to volume-regulating hormones. Plasma EPO, angiotensin II (ANGII), aldosterone, pro-atrial natriuretic peptide (proANP) and copeptin concentrations were measured at supine rest and up to 3 h during 30° head-up (HUT) and head-down tilt (HDT) in ten healthy male volunteers. Plasma albumin concentration was used to correct for changes in plasma volume and CVP was estimated through the internal jugular vein (IJV) aspect ratio with ultrasonography. From supine rest, the IJV aspect ratio was decreased and increased throughout HUT and HDT respectively. Plasma EPO concentration increased during HUT (13%; P = 0.001, P for linear component = 0.017), independent of changes in albumin concentration. Moreover, ANGII and copeptin concentrations increased during HUT, while proANP decreased. The increase in EPO concentration during HUT disappeared when adjusted for changes in copeptin. During HDT, EPO, ANGII and copeptin concentrations remained unaffected while proANP increased. In regression analyses, EPO was positively associated with copeptin (β = 0.55; 95% CI = 0.18, 0.93; P = 0.004) irrespective of changes in other hormones and albumin concentration. Reduction in CVP prompts an increase in plasma EPO concentration independent of hemoconcentration and hence suggests CVP per se as an acute regulator of EPO synthesis. This effect may be explained by changes in volume-regulating hormones. © 2016 Scandinavian Physiological Society. Published by John Wiley & Sons Ltd.
NASA Technical Reports Server (NTRS)
Convertino, V. A.; Sather, T. M.
2000-01-01
The purpose of this investigation was to test the hypothesis that peripheral vasoconstriction and orthostatic tolerance are associated with increased circulating plasma concentrations of noradrenaline, vasopressin and renin-angiotensin. Sixteen men were categorized as having high (HT, n=9) or low (LT, n=7) tolerance to lower body negative pressure (LBNP) based on whether the endpoint of their pre-syncopal-limited LBNP (peak LBNP) exposure exceeded -60 mmHg. The two groups were matched for age, height, weight, leg volume, blood volume and maximal oxygen uptake, as well as baseline blood volume and plasma concentrations of vasoactive hormones. Peak LBNP induced similar reductions in mean arterial pressure in both groups. The reduction in leg arterial pulse volume (measured by impedance rheography), an index of peripheral vascular constriction, from baseline to peak LBNP was greater (P<0.05) in the HT group (-0.041 +/- 0.005 ml 100 ml-1) compared to the reduction in the LT group (-0. 025 +/- 0.003 ml 100 ml-1). Greater peak LBNP in the HT group was associated with higher (P<0.05) average elevations in plasma concentrations of vasopressin (pVP, Delta=+7.2 +/- 2.0 pg ml-1) and plasma renin-angiotensin (PRA, Delta=+2.9 +/- 1.3 ng Ang II ml-1 h-1) compared to average elevations of pVP (+2.2 +/- 1.0 pg ml-1) and PRA (+0.1 +/- 0.1 ng Ang II ml-1 h-1) in the LT group. Plasma noradrenaline concentrations were increased (P<0.05) from baseline to peak LBNP in both HT and LT groups, with no statistically distinguishable difference between groups. These data suggest that the renin-angiotensin and vasopressin systems may contribute to sustaining arterial pressure and orthostatic tolerance by their vasoconstrictive actions.
Paracetamol plasma and cerebrospinal fluid pharmacokinetics in children
Anderson, B J; Holford, N H G; Woollard, G A; Chan, P L S
1998-01-01
Aims Paracetamol has a central action for both antipyresis and analgesia. Maximum temperature decrease and peak analgesia are reported at 1–2 h after peak plasma paracetamol concentration. We wished to determine the relationship between plasma and cerebrospinal fluid (CSF) pharmacokinetics in children. Methods Concentration-time profiles in plasma and CSF after nasogastric paracetamol 40 mg kg−1 were measured in nine children who had indwelling ventricular drains. Estimation of population pharmacokinetic parameters was made using both a standard two-stage population approach (MKMODEL) and a nonlinear mixed effect model (NONMEM). Results were standardized to a 70 kg person using an allometric power model. Results Both approaches gave similar estimates. NONMEM parameter estimates were clearance 10.2 l h−1 (CV 47%), volume of distribution 67.1 l (CV 58%) and absorption rate constant 0.77 h−1 (CV 49%). Cerebrospinal fluid concentrations lagged behind those of plasma. The equilibration half time was 0.72 h (CV 117%). The CSF/plasma partition coefficient was 1.18 (CV 8%). Conclusions Higher concentrations in the CSF probably reflect the lower free water volume of plasma. The CSF equilibration half time suggests that CSF kinetics approximate more closely to the effect compartment than plasma, but further time is required for paracetamol to exert its effects. Effect site concentrations equilibrate slowly with plasma. Paracetamol should be given 1–2 h before anticipated pain or fever in children. PMID:9764964
Determination of plasma volume in anaesthetized piglets using the carbon monoxide (CO) method.
Heltne, J K; Farstad, M; Lund, T; Koller, M E; Matre, K; Rynning, S E; Husby, P
2002-07-01
Based on measurements of the circulating red blood cell volume (V(RBC)) in seven anaesthetized piglets using carbon monoxide (CO) as a label, plasma volume (PV) was calculated for each animal. The increase in carboxyhaemoglobin (COHb) concentration following administration of a known amount of CO into a closed circuit re-breathing system was determined by diode-array spectrophotometry. Simultaneously measured haematocrit (HCT) and haemoglobin (Hb) values were used for PV calculation. The PV values were compared with simultaneously measured PVs determined using the Evans blue technique. Mean values (SD) for PV were 1708.6 (287.3)ml and 1738.7 (412.4)ml with the CO method and the Evans blue technique, respectively. Comparison of PVs determined with the two techniques demonstrated good correlation (r = 0.995). The mean difference between PV measurements was -29.9 ml and the limits of agreement (mean difference +/-2SD) were -289.1 ml and 229.3 ml. In conclusion, the CO method can be applied easily under general anaesthesia and controlled ventilation with a simple administration system. The agreement between the compared methods was satisfactory. Plasma volume determined with the CO method is safe, accurate and has no signs of major side effects.
Inductively coupled Cl2/Ar plasma: Experimental investigation and modeling
NASA Astrophysics Data System (ADS)
Efremov, A. M.; Kim, Dong-Pyo; Kim, Chang-Il
2003-07-01
Electrophysical and kinetic characteristics of Cl2/Ar plasma were investigated to understand the influence of the addition of Ar on the volume densities and fluxes of active particles, both neutral and charged. Our analysis combined both experimental methods and plasma modeling. It was found that addition of Ar to Cl2 leads to deformation of the electron energy distribution function and an increase of the electron mean energy due to the ``transparency'' effect. Direct electron impact dissociation of Cl2 molecules represents the main source of chlorine atoms in the plasma volume. The contributions of stepwise dissociation and ionization involving Ar metastable atoms were found to be negligible. Addition of Ar to Cl2 causes the decrease of both electron and ion densities due to a decrease in the total ionization rate and the acceleration of heterogeneous decay of charged particles.
Deep anisotropic ICP plasma etching designed for high-volume MEMS manufacturing
NASA Astrophysics Data System (ADS)
Yu, Keven; Feldbaum, Michael; Pandhumsoporn, Tam; Gadgil, Prashant
1999-08-01
ICP plasma etching is gaining widespread acceptance as an enabling micromachining technology for advanced MEMS fabrication. Whereas this technology has shown a capability of delivering multiple novel applications for R and D, its acceptance by industry for high volume production has been limited. This acceptance into production will only occur when the plasma etching equipment with this technology offers the device performance, throughput, reliability, and uptime criteria required by a production facility. The design of the plasma etcher using this technology and the process capability it consequently delivers, has significant implications in making this a reality. Alcatel has been supplying such a technology to this MEMS industry for over 5 years and in the interim has evolved its product and process to make this technology production worthy. Alcatel's next generation etcher, the Alcatel 601E, offers multiple advantages to MEMS manufacturers in realizing their production goals.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Du, Yinchang, E-mail: ycdu@mail.ustc.edu.cn; Max-Planck Institute for Extraterrestrial Physics, D-85748 Garching; Li, Yangfang
In this paper, we propose a method to get more homogeneous plasma in the geometrically asymmetric capacitive coupled plasma (CCP) discharge. The dielectric barrier discharge (DBD) is used for the auxiliary discharge system to improve the homogeneity of the geometrically asymmetric CCP discharge. The single Langmuir probe measurement shows that the DBD can increase the electron density in the low density volume, where the DBD electrodes are mounted, when the pressure is higher than 5 Pa. By this manner, we are able to improve the homogeneity of the plasma production and increase the overall density in the target volume. At last,more » the finite element simulation results show that the DC bias, applied to the DBD electrodes, can increase the homogeneity of the electron density in the CCP discharge. The simulation results show a good agreement with the experiment results.« less
NASA Technical Reports Server (NTRS)
Grisaffe, Salvatore J.; Caves, Robert M.
1964-01-01
An investigation was undertaken to determine the feasibility of depositing integrally bonded plasma-sprayed tungsten coatings onto 80-volume-percent tungsten - 20-volume-percent uranium dioxide composites. These composites were face clad with thin tungsten foil to inhibit uranium dioxide loss at elevated temperatures, but loss at the unclad edges was still significant. By preheating the composite substrates to approximately 3700 degrees F in a nitrogen environment, metallurgically bonded tungsten coatings could be obtained directly by plasma spraying. Furthermore, even though these coatings were thin and somewhat porous, they greatly inhibited the loss of uranium dioxide. For example, a specimen that was face clad but had no edge cladding lost 5.8 percent uranium dioxide after 2 hours at 4750 dgrees F in flowing hydrogen. A similar specimen with plasma-spray-coated edges, however, lost only 0.75 percent uranium dioxide under the same testing conditions.
Atmospheric-pressure glow plasma synthesis of plasmonic and photoluminescent zinc oxide nanocrystals
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bilik, N., E-mail: bilik006@umn.edu, E-mail: kortshagen@umn.edu; Greenberg, B. L.; Yang, J.
In this paper, we present a large-volume (non-micro) atmospheric pressure glow plasma capable of rapid, large-scale zinc oxide nanocrystal synthesis and deposition (up to 400 μg/min), whereas in the majority of the literature, nanoparticles are synthesized using micro-scale or filamentary plasmas. The reactor is an RF dielectric barrier discharge with a non-uniform gap spacing. This design encourages pre-ionization during the plasma breakdown, making the discharge uniform over a large volume. The produced zinc oxide nanocrystals typically have diameters ranging from 4 to 15 nm and exhibit photoluminescence at ≈550 nm and localized surface plasmon resonance at ≈1900 cm{sup −1} due to oxygen vacancies. Themore » particle size can be tuned to a degree by varying the gas temperature and the precursor mixing ratio.« less
Patel, Vipulkumar; Celec, Peter; Grunt, Magdalena; Schwarzenbach, Heidi; Jenneckens, Ingo; Hillebrand, Timo
2016-01-01
Circulating cell-free DNA (ccfDNA) is a promising diagnostic tool and its size fractionation is of interest. However, kits for isolation of ccfDNA available on the market are designed for small volumes hence processing large sample volumes is laborious. We have tested a new method that enables enrichment of ccfDNA from large volumes of plasma and subsequently allows size-fractionation of isolated ccfDNA into two fractions with individually established cut-off levels of ccfDNA length. This method allows isolation of low-abundant DNA as well as separation of long and short DNA molecules. This procedure may be important e.g., in prenatal diagnostics and cancer research that have been already confirmed by our primary experiments. Here, we report the results of selective separation of 200- and 500-bp long synthetic DNA fragments spiked in plasma samples. Furthermore, we size-fractionated ccfDNA from the plasma of pregnant women and verified the prevalence of fetal ccfDNA in all fractions.
[Measurement of maternal plasma volume during pregnancy].
Uzan, S; Beaufils, M; Uzan, M; Donsimoni, R; Mareck, A; Salat-Baroux, J; Sureau, C
1988-02-01
An increased maternal plasma volume (PV) is a characteristic phenomenon of normal pregnancy, which may be related to a physiological decrease of peripheral resistances. The authors have studied the plasma volume of 1,105 patients distributed as follows: normal (387), permanently hypertensive patients (84), hypertensive patients during pregnancy (390), patients with apparently isolated RCIU (154) or with a pathological past-history during previous pregnancies (90). It appears that the PV is a sign of a severe HBP, and presents a rather early and good predictive value regarding the weight of the fetus and some complications such as severe UCIU and fetal death in utero. In case of pathological past events or pre-existing hypertension, the PV enables to differentiate rather well patients who will be prone to a complicated pregnancy. In view of these results, utilization and interpretation criteria of this parameter during pregnancies with hypertension or pregnancies in which there is a suspicion or a risk of intra-uterine growth delay, are defined.
Collective phenomena in volume and surface barrier discharges
NASA Astrophysics Data System (ADS)
Kogelschatz, U.
2010-11-01
Barrier discharges are increasingly used as a cost-effective configuration to produce non-equilibrium plasmas at atmospheric pressure. This way, copious amounts of electrons, ions, free radicals and excited species can be generated without significant heating of the background gas. In most applications the barrier is made of dielectric material. Major applications utilizing mainly dielectric barriers include ozone generation, surface cleaning and modification, polymer and textile treatment, sterilization, pollution control, CO2 lasers, excimer lamps, plasma display panels (flat TV screens). More recent research efforts are devoted to biomedical applications and to plasma actuators for flow control. Sinusoidal feeding voltages at various frequencies as well as pulsed excitation schemes are used. Volume as well as surface barrier discharges can exist in the form of filamentary, regularly patterned or diffuse, laterally homogeneous discharges. The physical effects leading to collective phenomena in volume and surface barrier discharges are discussed in detail. Special attention is paid to self-organization of current filaments and pattern formation. Major similarities of the two types of barrier discharges are elaborated.
Detection of IDH1 mutation in the plasma of patients with glioma.
Boisselier, Blandine; Gállego Pérez-Larraya, Jaime; Rossetto, Marta; Labussière, Marianne; Ciccarino, Pietro; Marie, Yannick; Delattre, Jean-Yves; Sanson, Marc
2012-10-16
The IDH1(R132H) mutation is both a strong prognostic predictor and a diagnostic hallmark of gliomas and therefore has major clinical relevance. Here, we developed a new technique to detect the IDH1(R132H) mutation in the plasma of patients with glioma. Small-size DNA (150-250 base pairs) was extracted from the plasma of 31 controls and 80 patients with glioma with known IDH1(R132H) status and correlated with MRI data. The IDH1(R132H) mutation was detected by a combination of coamplification at lower denaturation temperature and digital PCR. The small size DNA concentration was 1.2 ng/mL (range 0.1-6.6) in controls vs 1.2 ng/mL (range 0.1-50.3) in patients with glioma (p = not significant) and 0.9 ng/mL (0.0-3.0) in low-grade gliomas vs 1.5 ng/mL in high-grade gliomas (p < 0.01). The small size DNA concentration correlated with enhancing tumor volume (1.6 ng/mL [0.4-24.9] when <10 cm(3) and 14.0 ng/mL [0.6-50.3] when ≥10 cm(3)). The IDH1(R132H) mutation was detected in 15 out of 25 plasma DNA mixtures (60%) from patients with mutated tumors and in none of the 14 patients with a nonmutated tumor. The sensitivity increased with enhancing tumor volume (3/9 in nonenhancing tumors, 6/10 for enhancing volume <10 cm(3), and 6/6 for enhancing volume ≥10 cm(3)). With a specificity of 100% and a sensitivity related to the tumor volume and contrast enhancement, IDH1(R132H) identification has a valuable diagnostic accuracy in patients not amenable to biopsy.
Plasma Reforming of Liquid Hydrocarbon Fuels in Non-Thermal Plasma-Liquid Systems
2010-04-30
microporous liquid which has a very large ratio of the plasma-liquid contact surface to the plasma volume. As is known the ultrasonic (US) cavitation is a very...effective method for creating micropores in liquid [17]. Therefore, the DGCLW with additional US pumping is also very interesting for research and...electrodes. Another PLS reactor was prepared with the DGCLW working with the air flow in the liquid under the induced microporous
NASA Technical Reports Server (NTRS)
Ertl, Andrew Carl
1994-01-01
The hypothesized fluid shifts and resultant responses that occur during spaceflight are simulated by six-degree head down tilt (HDT) and water immersion (WI). The purpose of this study was to compare exercise thermoregulation before and after physiologic mechanisms reduce plasma volume (PV) in response to 24-hr HDT (HDT24). A secondary study utilized WI to reproduce the PV reduction of HDT24. Seven males were studied in two conditions: during 70 minutes of supine cycling ergometry at 58 percent of peak oxygen consumption following 1-hr HDT (HDT1) and HDT24; and up to 6 hr WI at 34.5 C. Plasma volume was reduced by 10.4 percent in HDT24 when compared to HDT1. Pre-exercise rectal temperature, T(sub re), was an average 0.22 C higher after HDT24. Rectal temperature increased during exercise with no interaction between time and treatment. The reduced PV and elevated pre-exercise T(sub re) had offsetting effects on thermoregulatory mechanisms, suggesting no alteration in the response at a given T(sub re). Plasma volume was reduced by 4.3 +/- 2.3 percent and 1.1 +/- 1.8 percent following HDT24 and WI, respectively, compared to upright chair rest. Although the reductions in PV were not significantly different, great intra-individual variability was evident. The ability to reproduce PV changes consistently with HDT and WI is limited by this variability.
Nguyen, T B; Cron, G O; Bezzina, K; Perdrizet, K; Torres, C H; Chakraborty, S; Woulfe, J; Jansen, G H; Thornhill, R E; Zanette, B; Cameron, I G
2016-12-01
Tumor CBV is a prognostic and predictive marker for patients with gliomas. Tumor CBV can be measured noninvasively with different MR imaging techniques; however, it is not clear which of these techniques most closely reflects histologically-measured tumor CBV. Our aim was to investigate the correlations between dynamic contrast-enhanced and DSC-MR imaging parameters and immunohistochemistry in patients with gliomas. Forty-three patients with a new diagnosis of glioma underwent a preoperative MR imaging examination with dynamic contrast-enhanced and DSC sequences. Unnormalized and normalized cerebral blood volume was obtained from DSC MR imaging. Two sets of plasma volume and volume transfer constant maps were obtained from dynamic contrast-enhanced MR imaging. Plasma volume obtained from the phase-derived vascular input function and bookend T1 mapping (Vp_Φ) and volume transfer constant obtained from phase-derived vascular input function and bookend T1 mapping (K trans _Φ) were determined. Plasma volume obtained from magnitude-derived vascular input function (Vp_SI) and volume transfer constant obtained from magnitude-derived vascular input function (K trans _SI) were acquired, without T1 mapping. Using CD34 staining, we measured microvessel density and microvessel area within 3 representative areas of the resected tumor specimen. The Mann-Whitney U test was used to test for differences according to grade and degree of enhancement. The Spearman correlation was performed to determine the relationship between dynamic contrast-enhanced and DSC parameters and histopathologic measurements. Microvessel area, microvessel density, dynamic contrast-enhanced, and DSC-MR imaging parameters varied according to the grade and degree of enhancement (P < .05). A strong correlation was found between microvessel area and Vp_Φ and between microvessel area and unnormalized blood volume (r s ≥ 0.61). A moderate correlation was found between microvessel area and normalized blood volume, microvessel area and Vp_SI, microvessel area and K trans _Φ, microvessel area and K trans _SI, microvessel density and Vp_Φ, microvessel density and unnormalized blood volume, and microvessel density and normalized blood volume (0.44 ≤ r s ≤ 0.57). A weaker correlation was found between microvessel density and K trans _Φ and between microvessel density and K trans _SI (r s ≤ 0.41). With dynamic contrast-enhanced MR imaging, use of a phase-derived vascular input function and bookend T1 mapping improves the correlation between immunohistochemistry and plasma volume, but not between immunohistochemistry and the volume transfer constant. With DSC-MR imaging, normalization of tumor CBV could decrease the correlation with microvessel area. © 2016 by American Journal of Neuroradiology.
NASA Astrophysics Data System (ADS)
Xie, Jingjin; Chen, Qiang; Suresh, Poornima; Roy, Subrata; White, James F.; Mazzeo, Aaron D.
2017-05-01
This work describes disposable plasma generators made from metallized paper. The fabricated plasma generators with layered and patterned sheets of paper provide a simple and flexible format for dielectric barrier discharge to create atmospheric plasma without an applied vacuum. The porosity of paper allows gas to permeate its bulk volume and fuel plasma, while plasma-induced forced convection cools the substrate. When electrically driven with oscillating peak-to-peak potentials of ±1 to ±10 kV, the paper-based devices produced both volume and surface plasmas capable of killing microbes. The plasma sanitizers deactivated greater than 99% of Saccharomyces cerevisiae and greater than 99.9% of Escherichia coli cells with 30 s of noncontact treatment. Characterization of plasma generated from the sanitizers revealed a detectable level of UV-C (1.9 nWṡcm-2ṡnm-1), modest surface temperature (60 °C with 60 s of activation), and a high level of ozone (13 ppm with 60 s of activation). These results deliver insights into the mechanisms and suitability of paper-based substrates for active antimicrobial sanitization with scalable, flexible sheets. In addition, this work shows how paper-based generators are conformable to curved surfaces, appropriate for kirigami-like “stretchy” structures, compatible with user interfaces, and suitable for sanitization of microbes aerosolized onto a surface. In general, these disposable plasma generators represent progress toward biodegradable devices based on flexible renewable materials, which may impact the future design of protective garments, skin-like sensors for robots or prosthetics, and user interfaces in contaminated environments.
Paper-based plasma sanitizers.
Xie, Jingjin; Chen, Qiang; Suresh, Poornima; Roy, Subrata; White, James F; Mazzeo, Aaron D
2017-05-16
This work describes disposable plasma generators made from metallized paper. The fabricated plasma generators with layered and patterned sheets of paper provide a simple and flexible format for dielectric barrier discharge to create atmospheric plasma without an applied vacuum. The porosity of paper allows gas to permeate its bulk volume and fuel plasma, while plasma-induced forced convection cools the substrate. When electrically driven with oscillating peak-to-peak potentials of ±1 to ±10 kV, the paper-based devices produced both volume and surface plasmas capable of killing microbes. The plasma sanitizers deactivated greater than 99% of Saccharomyces cerevisiae and greater than 99.9% of Escherichia coli cells with 30 s of noncontact treatment. Characterization of plasma generated from the sanitizers revealed a detectable level of UV-C (1.9 nW⋅cm -2 ⋅nm -1 ), modest surface temperature (60 °C with 60 s of activation), and a high level of ozone (13 ppm with 60 s of activation). These results deliver insights into the mechanisms and suitability of paper-based substrates for active antimicrobial sanitization with scalable, flexible sheets. In addition, this work shows how paper-based generators are conformable to curved surfaces, appropriate for kirigami-like "stretchy" structures, compatible with user interfaces, and suitable for sanitization of microbes aerosolized onto a surface. In general, these disposable plasma generators represent progress toward biodegradable devices based on flexible renewable materials, which may impact the future design of protective garments, skin-like sensors for robots or prosthetics, and user interfaces in contaminated environments.
Blood volume and orthostatic responses of men and women to a 13-day bedrest
NASA Technical Reports Server (NTRS)
Fortney, S.; Driscoll, T.; Steinmann, L.; Alfrey, C.
1992-01-01
Changes in blood volume during space flight are thought to contribute to decrements in postflight orthostatic function. The purpose of this study was to determine whether gender affects red cell mass and plasma volume during a short exposure to simulated microgravity, and whether gender differences in orthostatic tolerance ensure. Methods: Ten men (31.5 plus or minus 5.2 years, STD) and eleven normally menstruating women (33.3) plus or minus 6.0 STD) underwent 13 days of 6 degree head-down bedrest. Plasma volume (Iodine 125 labeled human serum albumin) and red cell mass (Carbon 51 labeled red blood cells) were measured before bedrest and on bedrest day 13. On the same days, orthostatic tolerance (OT) was determined as the maximal pressure during a presyncopalimited lower body negative pressure test. Results: Plasma volume (PV) and red cell mass (RCM) decreased in both groups with a greater PV decrease (P less than 0.05) in men (6.3 plus or minus 0.7 ml/kg) than in women (4.1 plus or minus 0.6 ml/kg). Decreases in red cell mass were similar (1.7 plus or minus 0.2 ml/kg in men and 1.7 plus or minus 0.2 ml/kg in women). OT was similar for men and women before bedrest (minus 78 plus or minus 6 mmHg in men versus minus 70 plus or minus 4 mmHg in women) and decreased by a similar degree (by an average of 11 mmHg in both groups) after bedrest. The changes in OT did not correlate with changes in plasma volume during bedrest (r(exp 2) = 0.002). Conclusion: Thus, although female hormones may protect PV during bedrest, they do no appear to offer an advantage in terms of loss of orthostatic function.
NASA Technical Reports Server (NTRS)
French, R. A.; Cohen, B. A.; Miller, J. S.
2014-01-01
The Potassium-Argon Laser Experiment( KArLE), is composed of two main instruments: a spectrometer as part of the Laser-Induced Breakdown Spectroscopy (LIBS) method and a Mass Spectrometer (MS). The LIBS laser ablates a sample and creates a plasma cloud, generating a pit in the sample. The LIBS plasma is measured for K abundance in weight percent and the released gas is measured using the MS, which calculates Ar abundance in mols. To relate the K and Ar measurements, total mass of the ablated sample is needed but can be difficult to directly measure. Instead, density and volume are used to calculate mass, where density is calculated based on the elemental composition of the rock (from the emission spectrum) and volume is determined by pit morphology. This study aims to reduce the uncertainty for KArLE by analyzing pit volume relationships in several analog materials and comparing methods of pit volume measurements and their associated uncertainties.
Bed-rest studies - Fluid and electrolyte responses
NASA Technical Reports Server (NTRS)
Greenleaf, J. E.
1983-01-01
Confinement in the horizontal position for 2 to 3 weeks results in a chronic decrease in plasma volume, increased interstitial fluid volume, and unchanged or slightly increased extracellular fluid volume. Concentrations of blood electrolytes, glucose, and nitrogenous constituents remain within normal limits of variability when maintenance levels of isometric or isotonic exercise are performed for 1 hr/day. Hematocrit and plasma osmolality can be elevated significantly throughout bed rest (BR). Significant diuresis occurs on the first day, and increases in urine Na and Ca continue throughout BR, although voluntary fluid intake is unchanged. Urine Na and K are evaluated during the second week of BR in spite of stabilization of PV and extracellular volume. The initial diuresis probably arises from extracellular fluid while subsequent urine loss above control levels must come from the intracellular fluid. Preservation of the extracellular volume takes precedance over maintenance of the intracellular fluid volume. The functioning of a natriuretic factor (hormone) to account for the continued increased loss of Na in the urine is suggested. Previously announced in STAR as N83-24160
How to Ignite an Atmospheric Pressure Microwave Plasma Torch without Any Additional Igniters
Leins, Martina; Gaiser, Sandra; Schulz, Andreas; Walker, Matthias; Schumacher, Uwe; Hirth, Thomas
2015-01-01
This movie shows how an atmospheric pressure plasma torch can be ignited by microwave power with no additional igniters. After ignition of the plasma, a stable and continuous operation of the plasma is possible and the plasma torch can be used for many different applications. On one hand, the hot (3,600 K gas temperature) plasma can be used for chemical processes and on the other hand the cold afterglow (temperatures down to almost RT) can be applied for surface processes. For example chemical syntheses are interesting volume processes. Here the microwave plasma torch can be used for the decomposition of waste gases which are harmful and contribute to the global warming but are needed as etching gases in growing industry sectors like the semiconductor branch. Another application is the dissociation of CO2. Surplus electrical energy from renewable energy sources can be used to dissociate CO2 to CO and O2. The CO can be further processed to gaseous or liquid higher hydrocarbons thereby providing chemical storage of the energy, synthetic fuels or platform chemicals for the chemical industry. Applications of the afterglow of the plasma torch are the treatment of surfaces to increase the adhesion of lacquer, glue or paint, and the sterilization or decontamination of different kind of surfaces. The movie will explain how to ignite the plasma solely by microwave power without any additional igniters, e.g., electric sparks. The microwave plasma torch is based on a combination of two resonators — a coaxial one which provides the ignition of the plasma and a cylindrical one which guarantees a continuous and stable operation of the plasma after ignition. The plasma can be operated in a long microwave transparent tube for volume processes or shaped by orifices for surface treatment purposes. PMID:25938699
Method of high-precision microsampled blood and plasma mass densitometry
NASA Technical Reports Server (NTRS)
Hinghofer-Szalkay, H.
1986-01-01
The reliability of the mechanical oscillator technique for blood and plasma density measurements on samples of volumes less than 0.1 ml is examined, and a precision of 0.001 g/l is found if plasma-isodensic heparin solution and siliconized densitometers are employed. Sources of measurement errors in the density determinations include storage of plasma samples, inhomogeneity of blood samples, and density reading before adequate temperature equilibration. In tests of plasma sample storage, the best reproducibility was obtained with samples kept at 4 C. Linear correlations were found between plasma density and plasma protein concentration, blood density and blood hemoglobin concentration, and erythrocyte density and MCHC.
Turbulence, selective decay, and merging in the SSX plasma wind tunnel
NASA Astrophysics Data System (ADS)
Gray, Tim; Brown, Michael; Flanagan, Ken; Werth, Alexandra; Lukin, V.
2012-10-01
A helical, relaxed plasma state has been observed in a long cylindrical volume. The cylinder has dimensions L = 1 m and R = 0.08 m. The cylinder is long enough so that the predicted minimum energy state is a close approximation to the infinite cylinder solution. The plasma is injected at v >=50 km/s by a coaxial magnetized plasma gun located at one end of the cylindrical volume. Typical plasma parameters are Ti= 25 eV, ne>=10^15 cm-3, and B = 0.25 T. The relaxed state is rapidly attained in 1--2 axial Alfv'en times after initiation of the plasma. Magnetic data is favorably compared with an analytical model. Magnetic data exhibits broadband fluctuations of the measured axial modes during the formation period. The broadband activity rapidly decays as the energy condenses into the lowest energy mode, which is in agreement to the minimum energy eigenstate of ∇xB = λB. While the global structure roughly corresponds to the minimum energy eigenstate for the wind tunnel geometry, the plasma is high beta (β= 0.5) and does not have a flat λ profile. Merging of two plasmoids in this configuration results in noticeably more dynamic activity compared to a single plasmoid. These episodes of activity exhibit s
Changes in plasma thrombospondin-1 concentrations following acute intracerebral hemorrhage.
Dong, Xiao-Qiao; Yu, Wen-Hua; Zhu, Qiang; Cheng, Zhen-Yu; Chen, Yi-Hua; Lin, Xiao-Feng; Ten, Xian-Lin; Tang, Xiao-Bing; Chen, Juan
2015-10-23
Angiogenesis is a fundamental process for brain development and repair. Thrombospondin-1 is the first identified endogenous angiogenesis inhibitor. Its expression in rat brain is upregulated after intracerebral hemorrhage (ICH). We determined whether plasma thrombospondin-1 concentrations are associated with injury severity and prognosis in ICH patients. This observational, prospective study recruited 110 patients and 110 age- and gender-matched healthy controls. Blood samples were collected from the patients at admission and from the healthy controls at study entry to measure plasma thrombospondin-1 concentrations. The endpoints included 1-week mortality, 6-month mortality, 6-month overall survival and 6-month unfavorable outcome (modified Rankin Scale score >2). Plasma thrombospondin-1 concentrations were markedly higher in patients than in healthy controls. Thrombospondin-1 was an independent predictive factor for all endpoints and plasma thrombospondin-1 concentrations were highly associated with injury severity reflected by hematoma volume and National Institutes of Health Stroke Scale score. Under receiver operating characteristic curves, plasma thrombospondin-1 concentrations had similar predictive values compared with hematoma volume and National Institutes of Health Stroke Scale score. Increased plasma thrombospondin-1 concentrations following ICH are independently associated with injury severity and short-term and long-term clinical outcomes. Copyright © 2015 Elsevier B.V. All rights reserved.
Blair, D; Rumack, B H
1977-01-01
We describe a capillary-sampling method for serum or plasma acetaminophen by cation-exchange chromatography. As little as 1.5 mul of plasma or serum and an equal volume of the internal standard (N-butyryl-p-aminophenol) were run, with a precision of +/- 5% between duplicates. Acetaminophen and the internal standard chromatographed in 32 and 50 min, respectively, distinct from intrinsic plasma peaks and peaks caused by other medications.
Broadus, Arthur E.; Kaminsky, Neil I.; Hardman, Joel G.; Sutherland, Earl W.; Liddle, Grant W.
1970-01-01
Kinetic parameters and the renal clearances of plasma adenosine 3′,5′-monophosphate (cyclic AMP) and guanosine 3′,5′-monophosphate (cyclic GMP) were evaluated in normal subjects using tritium-labeled cyclic nucleotides. Each tracer was administered both by single, rapid intravenous injection and by constant intravenous infusion, and the specific activities of the cyclic nucleotides in plasma and urine were determined. Both cyclic AMP and cyclic GMP were cleared from plasma by glomerular filtration. The kidney was found to add a variable quantity of endogenous cyclic AMP to the tubular urine, amounting to an average of approximately one-third of the total level of cyclic AMP excreted. Plasma was the source of virtually all of the cyclic GMP excreted. Plasma levels of the cyclic nucleotides appeared to be in dynamic steady state. The apparent volumes of distribution of both nucleotides exceeded extracellular fluid volume, averaging 27 and 38% of body weight for cyclic AMP and cyclic GMP, respectively. Plasma production rates ranged from 9 to 17 nmoles/min for cyclic AMP and from 7 to 13 nmoles/min for cyclic GMP. Plasma clearance rates averaged 668 ml/min for cyclic AMP and 855 ml/min for cyclic GMP. Approximately 85% of the elimination of the cyclic nucleotides from the circulation was due to extrarenal clearance. PMID:5480849
Heat Acclimation and Water-Immersion Deconditioning: Responses to Exercise
NASA Technical Reports Server (NTRS)
Shvartz, E.; Bhattacharya, A.; Sperinde, S. J.; Brock, P. J.; Sciaraffa, D.; Haines, R. F.; Greenleaf, J. E.
1977-01-01
Simulated subgravity conditions, such as bed rest and water immersion, cause a decrease in a acceleration tolerance (3, 4), tilt tolerance (3, 9, 10), work capacity (5, 7), and plasma volume (1, 8-10). Moderate exercise training performed during bed rest (4) and prior to water immersion (5) provides some protection against the adverse effects of deconditioning, but the relationship between exercise and changes due to deconditioning remains unclear. Heat acclimation increases plasma and interstitial volumes, total body water, stroke volume (11), and tilt tolerance (6) and may, therefore, be a more efficient method of ameliorating deconditioning than physical training alone. The present study was undertaken to determine the effects of heat acclimation and moderate physical training, performed in cool conditions, on water-immersion deconditioning.
NASA Astrophysics Data System (ADS)
Grigoryev, D. V.; Voitsekhovskii, A. V.; Lozovoy, K. A.; Tarasenko, V. F.; Shulepov, M. A.
2015-11-01
In this paper the influence of the plasma volume discharge of nanosecond duration formed in a non-uniform electric field at atmospheric pressure on samples of epitaxial films HgCdTe (MCT) films are discussed. The experimental data show that the action of pulses of nanosecond volume discharge in air at atmospheric pressure leads to changes in the electrophysical properties of MCT epitaxial films due to formation of a near-surface high- conductivity layer of the n-type conduction. The preliminary results show that it is possible to use such actions in the development of technologies for the controlled change of the properties of MCT.
Interplanetary medium data book, supplement 4, 1985-1988
NASA Technical Reports Server (NTRS)
King, Joseph H.
1989-01-01
An extension is presented of the series of Interplanetary Medium Data Books and supplements which have been issued by the National Space Science Data Center since 1977. This volume contains solar wind magnetic field (IMF) and plasma data from the IMP 8 spacecraft for 1985 to 1988, and 1985 IMF data from the Czechoslovakian Soviet Prognoz 10 spacecraft. The normalization of the MIT plasma density and temperature, which has been discussed at length in previous volumes, is implemented as before, using the same normalization constants for 1985 to 1988 data as for the earlier data.
Hematology and immunology studies - The second manned Skylab mission
NASA Technical Reports Server (NTRS)
Kimzey, S. L.; Johnson, P. C.; Ritzman, S. E.; Mengel, C. E.
1976-01-01
The hematologic and immunologic functions of the Skylab 3 astronauts were monitored during the preflight, inflight, and postflight phases of the mission. Plasma protein profiles showed high consistency in all phases. A transient suppression of lymphocyte responsiveness was observed postflight. A reduction in the circulating blood volume due to drops in both the plasma volume and red cell mass was found. The loss of red cell mass is most likely a suppressed erythrypoiesis. The functional integrity of the circulating red cells did not appear to be compromised in the course of flight.
TECHNOLOGY EVALUATION REPORT: RETECH'S PLASMA CENTRIFUGAL FURNACE - VOLUME I
A demonstration of the Retech, Inc. Plasma Centrifugal Furnace (PCF) was conducted under the Superfund Innovative Technology Evaluation (SITE) Program at the Department of Energy's (DOE's) Component Development and Integration Facility in Butte, Montana. The furnace uses heat gen...
Body composition changes in men and women after 2-3 weeks of bed rest
NASA Technical Reports Server (NTRS)
Pace, N.; Kodama, A. M.; Grunbaum, B. W.; Rahlmann, D. F.; Price, D. C.; Newsom, B. D.
1976-01-01
Several parameters of body composition were measured in eight men before and after 14 days of continuous recumbency, and in eight women before and after 17 days of recumbency. The parameters measured included body weight, body water, body potassium, plasma volume, and plasma protein concentrations. From these, values were derived for body fat content, lean body mass, body mass, and circulating plasma proteins. In general, the men and women responded similarly to continuous recumbency. Characteristically, there was significant reduction of plasma volume and body potassium in both groups. The women showed a significant reduction in circulating plasma protein, entirely in the albumin fraction; a similar change was observed in the men. The women, but not the men, showed a significant increase in circulating fibrinogen. Both men and women lost body cell mass, while body fat content remained the same or tended to increase slightly. It is expected that similar changes would occur in weightlessness. It is further concluded that women should tolerate the weightlessness of space flight physiologically as well as men.
Inhibition of plasma vasopressin after drinking in dehydrated humans
NASA Technical Reports Server (NTRS)
Geelen, G.; Keil, L. C.; Kravik, S. E.; Wade, C. E.; Thrasher, T. N.; Barnes, P. R.; Pyka, G.; Nesvig, C.; Greenleaf, J. E.
1984-01-01
The effects of nonosmotic and nonvolumetric factors on vasopressin secretion in dehydrated humans has been investigated experimentally, before and after drinking. The subjects of the experiment were five adult men and three adult women weighing 69-77 kg. In order to determine the influence of nonosmotic and nonvolumetric factors on vasopressin secretion, measurements were obtained of the following blood hematological indices: serum Na(+) content; serum K(+) content; osmolality; and hemoglobin. Measurements of hematocrit, plasma arginine vasopressin (AVP), aldosterone, and renin activity were also obtained. It is found that dehydration increased mean serum Na(+) content, osmolality,and AVP. No significant changes were observed in renin activity, hemoglobin, hematocrit, or plasma volume, while plasma aldosterone increased from 11.1 ng/dl after dehydration to 15.6 ng/dl between 30 and 60 min after drinking. A rapid fall of AVP content following rehydration occurred in the absence of changes in the primary regulators of AVP osmolality and plasma volume, with no change in blood pressure. On the basis of the experimental results, it is suggested that oropharyngeal factors may be the mechanism, for the observed decrease in AVP following rehydration.
Atrial natriuretic factor increases vascular permeability
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lockette, W.; Brennaman, B.
An increase in central blood volume in microgravity may result in increased plasma levels of atrial natriuretic factor (ANF). Since elevations in plasma ANF are found in clinical syndromes associated with edema, and since space motion sickness induced by microgravity is associated with an increase in central blood volume and facial edema, we determined whether ANF increases capillary permeability to plasma protein. Conscious, bilaterally nephrectomized male rats were infused with either saline, ANF + saline, or hexamethonium + saline over 2 h following bolus injections of 125I-albumin and 14C-dextran of similar molecular size. Blood pressure was monitored and serial determinationsmore » of hematocrits were made. Animals infused with 1.0 micrograms.kg-1.min-1 ANF had significantly higher hematocrits than animals infused with saline vehicle. Infusion of ANF increased the extravasation of 125I-albumin, but not 14C-dextran from the intravascular compartment. ANF also induced a depressor response in rats, but the change in blood pressure did not account for changes in capillary permeability to albumin; similar depressor responses induced by hexamethonium were not accompanied by increased extravasation of albumin from the intravascular compartment. ANF may decrease plasma volume by increasing permeability to albumin, and this effect of ANF may account for some of the signs and symptoms of space motion sickness.« less
Effect of training on blood volume and plasma hormone concentrations in the elderly
NASA Technical Reports Server (NTRS)
Carroll, J. F.; Convertino, V. A.; Wood, C. E.; Graves, J. E.; Lowenthal, D. T.; Pollock, M. L.
1995-01-01
The purpose of this investigation was to determine the effects of 6 months of endurance training on resting plasma (PV) and blood volume (BV), and resting hormone and electrolyte concentrations in the elderly. Thirty-eight elderly men and women (ages 60-82 yr) were assigned to endurance exercise training (N = 29) or to control (N = 9) groups. Resting plasma levels of adrenocorticotropic hormone, vasopressin, aldosterone, norepinephrine, epinephrine, sodium, potassium, and protein were measured at the start (T1) and end (T2) of 26 wk of training. PV measurement was performed using the Evan's blue dye technique. Endurance training consisted of uphill treadmill walking or stairclimbing exercise 3 times.wk-1, 30-45 min.d-1, at 75-84% of maximal heart rate reserve. The exercise group increased VO2max by 11.2% (P < or = 0.05) and increased resting PV and BV by 11.2% and 12.7% (P < or = 0.05), respectively. Hormone and electrolyte levels in the exercise group remained unchanged; all variables were unchanged in the control group. These results are similar to findings in younger individuals. Because plasma hormone concentrations were maintained despite a chronically elevated BV, endurance training in healthy, elderly subjects may be associated with a resetting of volume receptors.
1986-04-01
Adams, R., Venna, P., Jackson, A., and Miller, R. TITLE: Plasma pharmacokinetics of intravenously administered atropine in normal human subjects Journal...atropine by i.v. route and inhalation. Measurements of respiratory airway resistance, N2 closing volume, maximal expiratory flow volume, pressure volume...maximum flow -static recoil and esophageal elasticity were compared to non-atropinized values. FINDINGS: "I.V. administration produced a marked
DOE Office of Scientific and Technical Information (OSTI.GOV)
Burger, T.; Keszthelyi, B.; Peer, J.
1962-02-25
Ten patients suffering from polycythemia vera were divided into three groups for evaluation purposes. The first group (2 patients) consisted of the mildest cases in which the hematocrit values were 55% or less. The second group (2 patients) had a hematocrit values of 55% or higher, and the red cell and plasma voiumes were higher than normal. The third group consisted of the severest cases with hematocrit values of 70 to 80%, red cell counts of 6 to 8 million/ mm/sup 3, and red cell and plasma volumes two to four times normai. Blood volumes were determined with /sup 32/Pmore » or /sup 51/Cr. The patients showed clinical improvement after the first treatment with /sup 32/P and hematologic examination indicated that the red cell count dropped, while hemogiobin value, white cell count, thrombocyte count, and hematocrit decreased. After the second / sup 32/P treatment the blood volume did not decrease appreciably, but plasma volume increased, leading to improvement of the patient's condition. Venesection may still be used as a therapeutic means when an immediate reduction of the blood volume is desired. This can be achieved by /sup 32/P therapy only after severai treatments. The /sup 32/P dose varied with the severity of the illness from one treatment of five mC /sup 32/P in the patients with hematocrits of 55% to two doses of 4.2 mC in those with values of 58%, and three mC /sup 32/P in another patient with a hematocrit of 82%. (BBB)« less
Vertically stabilized elongated cross-section tokamak
Sheffield, George V.
1977-01-01
This invention provides a vertically stabilized, non-circular (minor) cross-section, toroidal plasma column characterized by an external separatrix. To this end, a specific poloidal coil means is added outside a toroidal plasma column containing an endless plasma current in a tokamak to produce a rectangular cross-section plasma column along the equilibrium axis of the plasma column. By elongating the spacing between the poloidal coil means the plasma cross-section is vertically elongated, while maintaining vertical stability, efficiently to increase the poloidal flux in linear proportion to the plasma cross-section height to achieve a much greater plasma volume than could be achieved with the heretofore known round cross-section plasma columns. Also, vertical stability is enhanced over an elliptical cross-section plasma column, and poloidal magnetic divertors are achieved.
Effects of water immersion on plasma catecholamines in normal humans
NASA Technical Reports Server (NTRS)
Epstein, M.; Johnson, G.; Denunzio, A. G.
1983-01-01
An investigation was conducted in order to determine whether water immersion to the neck (NI) alters plasma catecholamines in normal humans. Eight normal subjects were studied during a seated control study (C) and during 4 hr of NI, and the levels of norepinephrine (NE) and epinephrine (E) as determined by radioenzymatic assay were measured hourly. Results show that despite the induction of a marked natriuresis and diuresis indicating significant central hypervolemia, NI failed to alter plasma NE or E levels compared with those of either C or the corresponding prestudy 1.5 hr. In addition, the diuresis and natriuresis was found to vary independently of NE. These results indicate that the response of the sympathetic nervous system to acute volume alteration may differ from the reported response to chronic volume expansion.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ghoos, K., E-mail: kristel.ghoos@kuleuven.be; Dekeyser, W.; Samaey, G.
2016-10-01
The plasma and neutral transport in the plasma edge of a nuclear fusion reactor is usually simulated using coupled finite volume (FV)/Monte Carlo (MC) codes. However, under conditions of future reactors like ITER and DEMO, convergence issues become apparent. This paper examines the convergence behaviour and the numerical error contributions with a simplified FV/MC model for three coupling techniques: Correlated Sampling, Random Noise and Robbins Monro. Also, practical procedures to estimate the errors in complex codes are proposed. Moreover, first results with more complex models show that an order of magnitude speedup can be achieved without any loss in accuracymore » by making use of averaging in the Random Noise coupling technique.« less
Noyes, Pamela D.; Lema, Sean C.; Roberts, Simon C.; Cooper, Ellen M.
2014-01-01
Thyroid hormones are critical regulators of normal development and physiological functioning in all vertebrates. Radioimmunoassay (RIA) approaches have been the method of choice for measuring circulating levels of thyroid hormones in vertebrates. While sensitive, RIA-based approaches only allow for a single analyte measurement per assay, can lack concordance across platforms and laboratories, and can be prone to analytical interferences especially when used with fish plasma. Ongoing advances in liquid chromatography tandem mass spectrometry (LC/MS/MS) have led to substantial decreases in detection limits for thyroid hormones and other biomolecules in complex matrices, including human plasma. Despite these advances, current analytical approaches do not allow for the measurement of native thyroid hormone in teleost fish plasma by mass spectrometry and continue to rely on immunoassay. In this study, we developed a new method that allows for the rapid extraction and simultaneous measurement of total T4 (TT4) and total T3 (TT3) in low volumes (50 μL) of fish plasma by LC/MS/MS. Methods were optimized initially in plasma from rainbow trout (Oncorhynchus mykiss) and applied to plasma from other teleost fishes, including fathead minnows (Pimephales promelas), mummichogs (Fundulus heteroclitus), sockeye salmon (Oncorhynchus nerka), and coho salmon (Oncorhynchus kisutch). Validation of method performance with T4- and T3-spiked rainbow trout plasma at 2 and 4 ng/mL produced mean recoveries ranging from 82 to 95 % and 97 to 105 %, respectively. Recovery of 13C12-T4 internal standard in plasma extractions was: 99±1.8 % in rainbow trout, 85±11 % in fathead minnow, 73±5.0 % in mummichog, 73±1.7 % in sockeye salmon, and 80±8.4 % in coho salmon. While absolute levels of thyroid hormones measured in identical plasma samples by LC/MS/MS and RIA varied depending on the assay used, T4/T3 ratios were generally consistent across both techniques. Less variability was measured among samples subjected to LC/MS/MS suggesting a more precise estimate of thyroid hormone homeostasis in the species targeted. Overall, a sensitive and reproducible method was established that takes advantage of LC/MS/MS techniques to rapidly measure TT4 and TT3 with negligible interferences in low volumes of plasma across a variety of teleost fishes. PMID:24343452
Sixteen-Day Bedrest Significantly Increases Plasma Colloid Osmotic Pressure
NASA Technical Reports Server (NTRS)
Hargens, Alan R.; Hsieh, S. T.; Murthy, G.; Ballard, R. E.; Convertino, V. A.; Wade, Charles E. (Technical Monitor)
1994-01-01
Upon exposure to microgravity, astronauts lose up to 10% of their total plasma volume, which may contribute to orthostatic intolerance after space flight. Because plasma colloid osmotic pressure (COP) is a primary factor maintaining plasma volume, our objective was to measure time course changes in COP during microgravity simulated by 6 deg. head-down tilt (HDT). Seven healthy male subjects (30-55 years of age) were placed in HDT for 16 days. For the purpose of another study, three of the seven subjects were chosen to exercise on a cycle ergometer on day 16. Blood samples were drawn immediately before bedrest on day 14 of bedrest, 18-24 hours following exercise while all subjects were still in HDT and 1 hour following bedrest termination. Plasma COP was measured in all 20 microliter EDTA-treated samples using an osmometer fitted with a PM 30 membrane. Data were analyzed with paired and unpaired t-tests. Plasma COP on day 14 of bedrest (29.9 +/- 0.69 mmHg) was significantly higher (p less than 0.005) than the control, pre-bedrest value (23.1 +/- 0.76 mmHg). At one hour of upright recovery after HDT, plasma COP remained significantly elevated (exercise: 26.9 +/- 0.87 mmHg; no exercise: 26.3 +/- 0.85 mmHg). Additionally, exercise had no significant effect on plasma COP 18-24 hours following exercise (exercise: 27.8 +/- 1.09 mmHg; no exercise: 27.1 +/- 0.78 mmHg). Our results demonstrate that plasma COP increases significantly with microgravity simulated by HDT. However, preliminary results indicate exercise during HDT does not significantly affect plasma COP.
Xie, Jingjin; Chen, Qiang; Suresh, Poornima; Roy, Subrata; White, James F.
2017-01-01
This work describes disposable plasma generators made from metallized paper. The fabricated plasma generators with layered and patterned sheets of paper provide a simple and flexible format for dielectric barrier discharge to create atmospheric plasma without an applied vacuum. The porosity of paper allows gas to permeate its bulk volume and fuel plasma, while plasma-induced forced convection cools the substrate. When electrically driven with oscillating peak-to-peak potentials of ±1 to ±10 kV, the paper-based devices produced both volume and surface plasmas capable of killing microbes. The plasma sanitizers deactivated greater than 99% of Saccharomyces cerevisiae and greater than 99.9% of Escherichia coli cells with 30 s of noncontact treatment. Characterization of plasma generated from the sanitizers revealed a detectable level of UV-C (1.9 nW⋅cm−2⋅nm−1), modest surface temperature (60 °C with 60 s of activation), and a high level of ozone (13 ppm with 60 s of activation). These results deliver insights into the mechanisms and suitability of paper-based substrates for active antimicrobial sanitization with scalable, flexible sheets. In addition, this work shows how paper-based generators are conformable to curved surfaces, appropriate for kirigami-like “stretchy” structures, compatible with user interfaces, and suitable for sanitization of microbes aerosolized onto a surface. In general, these disposable plasma generators represent progress toward biodegradable devices based on flexible renewable materials, which may impact the future design of protective garments, skin-like sensors for robots or prosthetics, and user interfaces in contaminated environments. PMID:28461476
Venous and autonomic function in formerly pre-eclamptic women and BMI-matched controls.
Heidema, Wieteke M; van Drongelen, Joris; Spaanderman, Marc E A; Scholten, Ralph R
2018-03-25
Pre-pregnancy reduced plasma volume increases the risk on subsequent pre-eclamptic pregnancy. Reduced plasma volume is thought to reflect venous reserve capacity, especially when venous vasculature is constricted and sympathetic tone is elevated. As obesity might affect these variables and also relates to pre-eclampsia, increased body weight may underlie these observations. We hypothesized that the relationship between reduced venous reserve and preeclampsia is independent of body mass index (BMI). We compared the non-pregnant venous reserve capacity in 30 formerly pre-eclamptic women, equally divided in 3 BMI-classes (BMI 19.5-24.9, BMI 25-29.9, BMI ≥30) to 30 controls. Cases and controls were matched for BMI, age and parity. The venous reserve capacity was quantified by assessing plasma volume and venous compliance. The autonomic nervous system regulating the venous capacitance was evaluated with heart rate variability analysis in resting supine position and during positive head-up tilt (HUT). Formerly pre-eclamptic women had in supine position lower plasma volume than controls (1339 ± 79 vs 1547 ± 139 ml/m 2 (p<0.001)), lower venous compliance (0.04 ± 0.02 vs 0.07 ± 0.02 ml/dl/mmHg (p<0.001)), higher sympathetic tone (1.9 ± 0.1 vs 1.2 ± 0.7 mmHg 2 (p=0.002)) and lower baroreceptor sensitivity (8.7 ± 3.8 vs 19.0 ± 1.7 ms/mmHg (p<0.001)). During HUT, women with a history of preeclampsia have less modulatory capacity over venous compliance and baroreceptor sensitivity, while heart rate and sympathetic tone remain consistently higher. Women with a history of pre-eclampsia have, compared to BMI-matched controls, reduced venous reserve capacity. This is reflected by lower plasma volume and venous compliance, the autonomic balance is shifted towards sympathetic dominance and lower baroreceptor sensitivity. This suggests that not BMI, but underlying reduced venous reserve relates to pre-eclampsia. This article is protected by copyright. All rights reserved.
Hypervolemia from Drinking Hyperhydration Solutions at Rest and Exercise
NASA Technical Reports Server (NTRS)
Greenleaf, John E.; Looft-Wilson, Robin; Jackson, Catherine G. R.; Geelen, Ghislaine; Barnes, Paul R.; Jensen, Christopher D.; Whittam, James H.
1995-01-01
The mechanism of muscular fatigue from physical work and exercise (high metabolism) is not clear, but involves disturbances of muscle surface membrane excitation-contraction coupling from changes in sarcoplasmic reticulum Ca2+ release, cell H+ and Pi responses, and carbohydrate metabolism. Fatigue in people at rest (low metabolism) involves both psychological and physiological factors, probably in different proportions. One common factor appears to be the level and distribution of water and electrolytes within muscle cells and other vascular, interstitial, body fluid compartments. The vascular fluid volume, composed of plasma and red blood cells, is a primary regulatory factor for cardiovascular function; reduction of vascular volume (hypovolemia) and total body water (hypohydration) adversely affect exercise performance. Plasma volume and plasma ionic-osmotic constituent concentrations are also regulatory factors for body thermoregulation, which is often compromised from exercise induced hypovolemia and hypohydration. Rehydration of dehydrated people on earth is relatively easy with appropriate food (osmols), fluid, and a restful environment. But ad libitum drinking under stressful conditions; e.g., heat, exercise, or prior dehydration, results in involuntary dehydration defined as the delay in full fluid replacement (euhydration) during and following loss of body fluid. Astronauts, with their reduced total body water are euhydrated while in weightlessness, but become "dehydrated" during reentry and landing. Thus, people subjected to acute or chronic stress are probably somewhat "dehydrated" as well as fatigued. Many rehydration drinks are more concentrated (hypertonic-hyperosmotic) with respect to the normal plasma osmolality of 285 mOsm/kg H2O and more of the drink osmols are contributed by carbohydrates than by ionized substances. There have been few studies on the efficacy of various drink formulations for increasing body fluid compartment volumes, especially plasma volume, in rested hydrated subjects. Recent findings from our laboratory have indicated that drinks containing greater concentrations of ionized substances (Performance 1 and AstroAde) up to 157 mEq/L Na+ induced greater levels of hypervolemia in resting, moderately dehydrated men, and were also better than water for attenuating the characteristic hypovolemia during supine, submaximal, leg ergometer exercise.
2000-03-24
Element Method for Designing Plasma Reactors" Leo Kempel, Paul Rummel, Tim Grotjohn and John Amrhein ............................................ 28...34Finite Element Method for Designing Plasma Reactors" Leo Kempel, Paul Rummel, Tim Grotjohn and John Amrhein...548 "lime-Domain Simulation of Electromagnetic Wave Propagation in a Magnetized Plasma" J. Paul , C. Christopoulos, and
NASA Technical Reports Server (NTRS)
Sawka, Michael N.; Convertino, Victor A.; Eichner, E. Randy; Schnieder, Suzanne M.; Young, Andrew J.
2000-01-01
This paper reviews the influence of several perturbations (physical exercise, heat stress, terrestrial altitude, microgravity, and trauma/sickness) on adaptations of blood volume (BV), erythrocyte volume (EV), and plasma volume (PV). Exercise training can induced BV expansion; PV expansion usually occurs immediately, but EV expansion takes weeks. EV and PV expansion contribute to aerobic power improvements associated with exercise training. Repeated heat exposure induces PV expansion but does not alter EV. PV expansion does not improve thermoregulation, but EV expansion improves thermoregulation during exercise in the heat. Dehydration decreases PV (and increases plasma tonicity) which elevates heat strain and reduces exercise performance. High altitude exposure causes rapid (hours) plasma loss. During initial weeks at altitude, EV is unaffected, but a gradual expansion occurs with extended acclimatization. BV adjustments contribute, but are not key, to altitude acclimatization. Microgravity decreases PV and EV which contribute to orthostatic intolerance and decreased exercise capacity in astronauts. PV decreases may result from lower set points for total body water and central venous pressure, which EV decrease bay result form increased erythrocyte destruction. Trauma, renal disease, and chronic diseases cause anemia from hemorrhage and immune activation, which suppressions erythropoiesis. The re-establishment of EV is associated with healing, improved life quality, and exercise capabilities for these injured/sick persons.
Methadone adverse reaction presenting with large increase in plasma methadone binding: a case series
2011-01-01
Introduction The use of methadone as an analgesic is on the increase, but it is widely recognized that the goal of predictable and reproducible dosing is confounded by considerable variability in methadone pharmacokinetics, and unpredictable side effects that include sedation, respiratory depression and cardiac arrhythmias. The mechanisms underlying these unpredictable effects are frequently unclear. Here, to the best of our knowledge we present the first report of an association between accidental methadone overexposure and increased plasma protein binding, a new potential mechanism for drug interactions with methadone. Case presentation We describe here the cases of two patients who experienced markedly different responses to the same dose of methadone during co-administration of letrozole. Both patients were post-menopausal Caucasian women who were among healthy volunteers participating in a clinical trial. Under the trial protocol both patients received 6 mg of intravenous methadone before and then after taking letrozole for seven days. One woman (aged 59) experienced symptoms consistent with opiate overexposure after the second dose of methadone that were reversed by naloxone, while the other (aged 49) did not. To understand the etiology of this event, we measured methadone pharmacokinetics in both patients. In our affected patient only, a fourfold to eightfold increase in methadone plasma concentrations after letrozole treatment was observed. Detailed pharmacokinetic analysis indicated no change in metabolism or renal elimination in our patient, but the percentage of unbound methadone in the plasma decreased 3.7-fold. As a result, the volume of distribution of methadone decreased approximately fourfold. The increased plasma binding in our affected patient was consistent with observed increases in plasma protein concentrations. Conclusions The marked increase in the total plasma methadone concentration observed in our patient, and the enhanced pharmacodynamic effect, appear primarily due to a reduced volume of distribution. The extent of plasma methadone binding may help to explain the unpredictability of its pharmacokinetics. Changes in volume of distribution due to plasma binding may represent important causes of clinically meaningful drug interactions. PMID:21985665
Pagano, M B; Metcalf, R A; Hess, J R; Reyes, J; Perkins, J D; Montenovo, M I
2018-04-01
During massive transfusion, the volume ratio of administered plasma (PL Vol) to red blood cell (RBC Vol) appears to be associated with reduced blood utilization and improved survival. The aim of this study was to evaluate the optimal component ratio in the setting of liver transplantation. This is a retrospective chart review of patients who underwent liver transplantation and received at least 500 ml of red blood cells from January 2013 through December 2015. Kernel smoothing analysis determined the proper component ratios to evaluate were a ≥0·85:1 ratio (high) to a ≤0·85:1 ratio (low). Two groups, plasma volume to RBC volume (PL Vol/RBC Vol) and plasma contained in the platelet units added to the plasma calculation [PL + PLT (platelet)] Vol/RBC Vol, were used to evaluate the component ratios. A total of 188 patients were included in the analysis. In the PL Vol/RBC Vol evaluation, a low ratio revealed that 1238 ml (977-1653 ml) (P < 0·0001) and 1178 ml (747-1178) (P < 0·0001) of RBC were used in excess compared to the high ratio, in the univariable and multivariable analysis, respectively. In the PL +PLT Vol/RBC Vol evaluation, a low ratio used 734 ml (193-1275) (P = 0·008) and 886 ml (431-1340) (P < 0·0001) of RBC in excess when compared to high ratio in the univariable and multivariable analysis, respectively. In patients undergoing liver transplantation, the transfusion of plasma to RBC ratio ≥0·85 was associated with decreased need of RBC transfusions. © 2018 International Society of Blood Transfusion.
PREFACE: 26th Summer School and International Symposium on the Physics of Ionized Gases (SPIG 2012)
NASA Astrophysics Data System (ADS)
Kuraica, Milorad; Mijatovic, Zoran
2012-11-01
This volume of Journal of Physics: Conference Series contains the general invited lectures, topical invited lectures and progress reports presented at the 26th Summer School and International Symposium on the Physics of Ionized Gases - SPIG 2012. The conference was held in Zrenjanin, Serbia, from 27-31 August. The SPIG conference has a 52 year long tradition. The structure of the papers in this volume cover the following sections: atomic collision processes, particle and laser beam interactions with solids, low temperature plasmas and general plasmas. As these four topics often overlap and merge in numerous fundamental studies and, more importantly applications, SPIG in general serves as a venue for exchanging ideas in the related fields. We hope that this volume will be an important source of information about progress in plasma physics and will be useful, first of all, for students, but also for plasma physics scientists. The Editors would like to thank the invited speakers for their participation at SPIG 2012 and for their efforts writing contributions for this volume. We also express our gratitude to the members of Scientific and Organizing committees for their efforts in organizing this SPIG. Especially we would like to thank the Ministry of Education, Science and Technological Development of Republic of Serbia, Provincial Secretariat for Science and Techonological Development, Province of Vojvodina, Institute Français de Serbie and Biser Zrenjanin for financial support as well as the European Physical Society (EPS) for supporting the award for the best poster of a young scientist and American Elements, USA. Milorad Kuraica Zoran Mijatovic October 2012 Editors
1985-01-01
Duck red cells exhibit specific volume-sensitive ion transport processes that are inhibited by furosemide, but not by ouabain. Swelling cells in a hypotonic synthetic medium activates a chloride- dependent, but sodium-independent, potassium transport. Shrinking cells in a hypertonic synthetic medium stimulates an electrically neutral co- transport of [Na + K + 2 Cl] with an associated 1:1 K/K (or K/Rb) exchange. These shrinkage-induced modes can also be activated in both hypo- and hypertonic solutions by beta-adrenergic catecholamines (e.g., norepinephrine). Freshly drawn cells spontaneously shrink approximately 4-5% when removed from the influence of endogenous plasma catecholamines, either by incubation in a catecholamine-free, plasma- like synthetic medium, or in plasma to which a beta-receptor blocking dose of propranolol has been added. This spontaneous shrinkage resembles the response of hypotonically swollen cells in that it is due to a net loss of KCl with no change in cell sodium. Norepinephrine abolishes the net potassium transport seen in both fresh and hypotonically swollen cells. Moreover, cells swollen in diluted plasma, at physiological pH and extracellular potassium, show no net loss of KCl and water ("volume-regulatory decrease") unless propranolol is added. Examination of the individual cation fluxes in the presence of catecholamines demonstrates that activation of [Na + K + 2Cl] co- transport with its associated K/Rb exchange prevents, or overrides, swelling-induced [K + Cl] co-transport. These results, therefore, cast doubt on whether the swelling-induced [K + Cl] system can serve a volume-regulatory function under in vivo conditions. PMID:3998706
Baker, W.R.
1961-08-22
A device is described for establishing and maintaining a high-energy, rotational plasma for use as a fast discharge capacitor. A disc-shaped, current- conducting plasma is formed in an axinl magnetic field and a crossed electric field, thereby creating rotational kinetic enengy in the plasma. Such energy stored in the rotation of the plasma disc is substantial and is convertible tc electrical energy by generator action in an output line electrically coupled to the plasma volume. Means are then provided for discharging the electrical energy into an external circuit coupled to the output line to produce a very large pulse having an extremely rapid rise time in the waveform thereof. (AE C)
Quantification of Dynamic 11C-Phenytoin PET Studies.
Mansor, Syahir; Boellaard, Ronald; Froklage, Femke E; Bakker, Esther D M; Yaqub, Maqsood; Voskuyl, Rob A; Schwarte, Lothar A; Verbeek, Joost; Windhorst, Albert D; Lammertsma, Adriaan
2015-09-01
The overexpression of P-glycoprotein (Pgp) is thought to be an important mechanism of pharmacoresistance in epilepsy. Recently, (11)C-phenytoin has been evaluated preclinically as a tracer for Pgp. The aim of the present study was to assess the optimal plasma kinetic model for quantification of (11)C-phenytoin studies in humans. Dynamic (11)C-phenytoin PET scans of 6 healthy volunteers with arterial sampling were acquired twice on the same day and analyzed using single- and 2-tissue-compartment models with and without a blood volume parameter. Global and regional test-retest (TRT) variability was determined for both plasma to tissue rate constant (K1) and volume of distribution (VT). According to the Akaike information criterion, the reversible single-tissue-compartment model with blood volume parameter was the preferred plasma input model. Mean TRT variability ranged from 1.5% to 16.9% for K1 and from 0.5% to 5.8% for VT. Larger volumes of interest showed better repeatabilities than smaller regions. A 45-min scan provided essentially the same K1 and VT values as a 60-min scan. A reversible single-tissue-compartment model with blood volume seems to be a good candidate model for quantification of dynamic (11)C-phenytoin studies. Scan duration may be reduced to 45 min without notable loss of accuracy and precision of both K1 and VT, although this still needs to be confirmed under pathologic conditions. © 2015 by the Society of Nuclear Medicine and Molecular Imaging, Inc.
Fluid-electrolyte shifts and thermoregulation - Rest and work in heat with head cooling
NASA Technical Reports Server (NTRS)
Greenleaf, J. E.; Van Beaumont, W.; Brock, P. J.; Montgomery, L. D.; Morse, J. T.; Shvartz, E.; Kravik, S.
1980-01-01
The effects of head cooling on thermoregulation and associated plasma fluid and electrolyte shifts during rest and submaximal exercise in the heat are investigated. Thermoregulatory responses and plasma volume were measured in four male subjects fitted with liquid-cooled neoprene headgear during 60 min of rest, 60 min of ergometer exercise at 45% maximal oxygen uptake and 30 min of recovery in the supine position at 40.1 C and 40% relative humidity. It is found that, compared to control responses, head cooling decreased thigh sweating and increased mean skin temperature at rest and attenuated increases in thigh sweating, heart rate, rectal temperature and ventilation during exercise. During recovery, cooling is observed to facilitate decreases in sweat rate, heart rate, rectal temperature and forearm blood flow and enhance the increase in average temperature. Cooling had no effect on plasma protein, osmotic or electrolyte shifts, and decreased plasma volume losses. The findings indicate the effectiveness of moderate head cooling for the improvement of human performance during exercise in heat.
Study of negative ion transport phenomena in a plasma source
NASA Astrophysics Data System (ADS)
Riz, D.; Paméla, J.
1996-07-01
NIETZSCHE (Negative Ions Extraction and Transport ZSimulation Code for HydrogEn species) is a negative ion (NI) transport code developed at Cadarache. This code calculates NI trajectories using a 3D Monte-Carlo technique, taking into account the main destruction processes, as well as elastic collisions (H-/H+) and charge exchanges (H-/H0). It determines the extraction probability of a NI created at a given position. According to the simulations, we have seen that in the case of volume production, only NI produced close to the plasma grid (PG) can be extracted. Concerning the surface production, we have studied how NI produced on the PG and accelerated by the plasma sheath backward into the source could be extracted. We demonstrate that elastic collisions and charge exchanges play an important role, which in some conditions dominates the magnetic filter effect, which acts as a magnetic mirror. NI transport in various conditions will be discussed: volume/surface production, high/low plasmas density, tent filter/transverse filter.
Plasma diagnostics package. Volume 2: Spacelab 2 section. Part B: Thesis projects
NASA Technical Reports Server (NTRS)
Pickett, Jolene S. (Compiler); Frank, L. A. (Compiler); Kurth, W. S. (Compiler)
1988-01-01
This volume (2), which consists of two parts (A and B), of the Plasma Diagnostics Package (PDP) Final Science Report contains a summary of all of the data reduction and scientific analyses which were performed using PDP data obtained on STS-51F as a part of the Spacelab 2 (SL-2) payload. This work was performed during the period of launch, July 29, 1985, through June 30, 1988. During this period the primary data reduction effort consisted of processing summary plots of the data received by 12 of the 14 instruments located on the PDP and submitting these data to the National Space Science Data Center (NSSDC). Three Master's and three Ph.D. theses were written using PDP instrumentation data. These theses are listed in Volume 2, Part B.
Metabolic changes observed in astronauts
NASA Technical Reports Server (NTRS)
Leach, Carolyn S.; Cintron, N. M.; Krauhs, J. M.
1991-01-01
Results of medical experiments with astronauts reveal rapid loss of volume (2 l) from the legs and a transient early increase in left ventricular volume index. These findings indicate that, during space flight, fluid is redistributed from the legs toward the head. In about 2 days, total body water decreases 2 to 3 percent. Increased levels of plasma renin activity and antidiuretic hormone while blood sodium and plasma volume are reduced suggest that space flight-associated factors are influencing the regulatory systems. In addition to fluid and electrolyte loss, Skylab astronauts lost an estimated 0.3 kg of protein. Endocrine factors, including increased cortisol and thyroxine and decreased insulin, are favorable for protein catabolism. The body appears to adapt to weightlessness at some physiologic cost. Readaptation to earth's gravity at landing becomes another physiologic challenge.
Mechanisms of lower body negative pressure-induced syncope
NASA Astrophysics Data System (ADS)
Davrath, Linda Ruble
Although extensively investigated, the mechanisms of post-spaceflight orthostatic intolerance have not been elucidated. The working hypothesis was that a markedly reduced left ventricular end-systolic volume (LVESV) would be achieved during progressive, presyncopal-limited LBNP and would cause bradycardia and a fall in blood pressure, thus triggering syncope. Eight healthy men, age 25.1 ± 1.3 years, volunteered for the study. Subjects were exposed to graded levels of LBNP on two separate occasions. Changes in left ventricular end-diastolic volume and LVESV were measured, using two-dimensional echocardiography, at each stage of LBNP from rest to presyncope. Plasma venous blood samples were withdrawn at the end of each stage of the LBNP protocol for the measurement of plasma venous catecholamines and plasma renin activity (PRA). Catecholamines were analyzed by HPLC with electro-chemical detection, and PRA was determined by radioimmunoassay. All subjects reached presyncope during the LBNP. LVESV decreased by 28% at presyncope with no evidence of ventricular cavity obliteration. Norepinephrine (NE) increased by 44% from rest to presyncope, but no epinephrine surge was detected (35% increase from rest to presyncope). These data indicate that it is possible to initiate syncope with only a 28% decrease in LVESV, and that sympatho-inhibition and bradycardia are not required elements for syncope to occur. To investigate the effect of moderate sodium restriction on cardiovascular hemodynamics and orthostatic tolerance, presyncopal LBNP testing was performed. Urinary sodium excretion was significantly higher on the normal-sodium diet when compared with the sodium-restricted diet, but urinary potassium was not different. Cumulative stress index (655 ± 460 on normal-sodium diet vs. 639 ± 388 on sodium-restricted diet) scores were not different. Cardiac volumes, blood pressure and total peripheral resistance were not different at any stage of the LBNP between the diets, nor were plasma catecholamine levels. Heart rate was significantly higher at presyncope on the sodium-restricted diet. Plasma renin activity was significantly higher during sodium restriction at rest, and during all stages of LBNP. Moderate dietary sodium restriction was not accompanied by apparent plasma volume reduction (hematocrit, body weight change), and did not appear to be detrimental to orthostatic function.
NASA Technical Reports Server (NTRS)
1976-01-01
Results of studies performed on the magnetospheric and plasma portion of the AMPS are presented. Magnetospheric and plasma in space experiments and instruments are described along with packaging (palletization) concepts. The described magnetospheric and plasma experiments were considered as separate entities. Instrumentation ospheric and plasma experiments were considered as separate entities. Instrumentation requirements and operations were formulated to provide sufficient data for unambiguous interpretation of results without relying upon other experiments of the series. Where ground observations are specified, an assumption was made that large-scale additions or modifications to existing facilities were not required.
PULSION® HP: Tunable, High Productivity Plasma Doping
NASA Astrophysics Data System (ADS)
Felch, S. B.; Torregrosa, F.; Etienne, H.; Spiegel, Y.; Roux, L.; Turnbaugh, D.
2011-01-01
Plasma doping has been explored for many implant applications for over two decades and is now being used in semiconductor manufacturing for two applications: DRAM polysilicon counter-doping and contact doping. The PULSION HP is a new plasma doping tool developed by Ion Beam Services for high-volume production that enables customer control of the dominant mechanism—deposition, implant, or etch. The key features of this tool are a proprietary, remote RF plasma source that enables a high density plasma with low chamber pressure, resulting in a wide process space, and special chamber and wafer electrode designs that optimize doping uniformity.
Drive electrostatic plasma oscillations in a closed electron drift accelerator
DOE Office of Scientific and Technical Information (OSTI.GOV)
Morozov, A.I.; Nevrovskii, V.A.; Smirnov, V.A.
1973-09-01
The present work describes and experimental investigation of the perturbations created in the plasma of a closed electron drift accelerator (CEDA) by a time-varying potential applied to an electrode in the plasma. In particular, the driven electrostatic oscillations are in phase over the entire volume of the channel and the attenuation of the signal amplitude is sensitive to the direction of the electron flux in the accelerator. Certain aspects of the propagation of the harmonic signals and pulses in the plasma are established. A substantial drop in signal amplitude occurs between the electrode and the plasma. (auth)
Guignier, C; Benamara, A; Oriol, P; Coppo, P; Mariat, C; Garraud, O
2018-02-01
A retrospective - single center - survey compared tolerance of individual donor therapeutic plasma in a series of 88 patients principally presenting with thrombotic microangiopathy; all patients underwent therapeutic plasma exchange (TPE) performed with more than 90% of either of two types of plasma preparations. One plasma type used in TPE was prepared with pathogen reduction by amotosalen addition and UVA illumination, and the other one was non-manipulated (quarantine plasma). Both types of plasma were single donor. Occurrences of adverse reactions were equally low in either arm (amotosalen: 9 in 4689 bags of ∼200mL [0.019] versus quarantine: 2 in 828 bags [0.024]), confirming the safe use of amotosalen inactivated therapeutic plasma for TPE. Copyright © 2017 Elsevier Masson SAS. All rights reserved.
Hydration and blood volume effects on human thermoregulation in the heat: Space applications
NASA Technical Reports Server (NTRS)
Sawka, Michael N.; Gonzalez, Richard R.; Pandolf, Kent B.
1994-01-01
Astronauts exposed to prolonged weightlessness will experience deconditioning, dehydration, and hypovolemia which all adversely affect thermoregulation. These thermoregulatory problems can be minimized by several countermeasures that manipulate body water and vascular volumes. USARIEM scientists have extensively studied dehydration effects and several possible countermeasures including hyperhydration, plasma and erythrocyte volume expansion. This paper reviews USARIEM research into these areas.
NASA Technical Reports Server (NTRS)
Greenleaf, J. E.; Lee, P. L.; Ellis, S.; Selzer, R. H.; Ortendahl, D. A.
1994-01-01
Magnetic resonance imaging (MRI) was used to compare the effect of two modes of lower-extremity exercise training on the mass (volume) of posterior leg group (PLG) muscles (soleus, flexor hallucis longus, tibialis posterior, lateral and medial gastrocnemius, and flexor digitorum longus) on 19 men (ages 32-42 years) subjected to intense dynamic-isotonic (ITE, cycle ergometer, number of subjects (N) = 7), isokinetic (IKE, torque egrometer, N = 7), and no exercise (NOE, N = 5) training for 60 min/day during head-down bed rest (HDBR). Total volume of the PLG muscles decreased (p less than 0.05) similarly: ITE = 4.3 +/- SE 1.6%, IKE = 7.7 +/- 1.6%, and NOE = 6.3 +/- 0.8%; combined volume (N = 19) loss was 6.1 +/- 0.9%. Ranges of volume changes were 2.6% to -9.0% (ITE), -2.1% to -14.9% (IKE), and -3.4% to -8/1% (NOE). Correlation coefficients (r) of muscle volume versus thickness measured with ultrasonography were: ITE r + 0.79 (p less than 0.05), IKE r = 0.27 (not significant (NS)), and NOE r = 0.63 (NS). Leg-muscle volume and thickness were highly correlated (r = 0.79) when plasma volume was maintained during HDBR with ITE. Thus, neither intensive lower extremity ITE nor IKE training influence the normal non-exercised posterior leg muscle atrophy during HDBR. The relationship of muscle volume and thickness may depend on the mode of exercise training associated with the maintenance of plasma volume.
Gavra, Paul; Nguyen, Anne Q-N; Theoret, Yves; Litalien, Catherine; Denault, André Y; Varin, France
2014-10-01
Milrinone administered through inhalation is an emerging method aimed at specifically reducing pulmonary hypertension without affecting systemic pressures. Its administration has been shown to be useful both in patients undergoing cardiac surgery and for persistent pulmonary hypertension of the newborn. These populations are prone to receive many concomitant medications and/or blood sampling may require a low volume quantification method. To address these issues in view of pharmacokinetic studies, this article aims to develop and validate a specific and sensitive analytical assay using high performance liquid chromatography (HPLC) and tandem mass spectrometry (MS/MS) detection for the quantification of milrinone plasma concentrations after inhalation in patients undergoing cardiac surgery. Plasma samples (50 μL) were extracted using ethyl acetate. Milrinone was separated on a C18 analytical column at 50°C. The mobile phase consisted of methanol and 10 mM ammonium acetate (45:55 vol/vol). The electrospray was operated in the negative ionization mode and monitored the following mass transitions: m/z 212.1 → 140.0 at 36 eV for milrinone and m/z 252.1 → 156.1 at 32 eV for olprinone. Calibration curves followed a quadratic regression in the concentration range of 0.3125-640 ng/mL. The lower limit of quantification is 0.3125 ng/mL and is based on a low plasma volume of 50 μL. Mean drug recovery and accuracy were ≥72.3% and 96.0%, respectively. Intraday and interday precision coefficient of variation (%) was ≤7.4% and ≤11.5%, respectively. The specificity allowed milrinone quantification in the multidrug administration conditions of cardiopulmonary bypass. This validated micromethod proved to be highly sensitive and specific while using a low volume of plasma. Its low volume and its lower limit of quantification indicate that this approach is suitable for further characterization of milrinone pharmacokinetics in both adults (inhalation) and neonates.
1963-06-01
RESISTANCE COATINGS "FOR GRAPHITE TECHNICAL DOCUMENTARY REPORT NO. WADD TR 61-72, Volume XXXIV ELECT" June 1963 D-I’C a AUý 0 219940 -14 0u c 94Air Force... coating on\\ Ex.: C (substrate’) + SiC1 R. SiC + graphite, + 4HCI (gas) oo flush Z000C 2 277I I I Deposition of coatings by plasma spraying also has...materials to withstand high tem- peratures has led to the investigation of the plasma torch as a means for 3 depositing protective coatings
Isaacs, P E; Ladas, S; Forgacs, I C; Dowling, R H; Ellam, S V; Adrian, T E; Bloom, S R
1987-05-01
In a double-blind, crossover study of the effect of ingested medium-chain triglyceride (MCT) and long-chain triglyceride (LCT) in six normal subjects, the gallbladder did not contract after ingestion of MCT but instead had significantly increased in volume at 2 hr after the meal. Plasma cholecystokinin (CCK) increased after the MCT meal, but gastrin, motilin, pancreatic polypeptide (PP), and GIP were unaffected. The long-chain triglyceride meal evoked a brisk and sustained gallbladder contraction, higher levels of CCK, and a significant increase in plasma PP and GIP levels.
Transparency of an instantaneously created electron-positron-photon plasma
NASA Astrophysics Data System (ADS)
Bégué, D.; Vereshchagin, G. V.
2014-03-01
The problem of the expansion of a relativistic plasma generated when a large amount of energy is released in a small volume has been considered by many authors. We use the analytical solution of Bisnovatyi-Kogan and Murzina for the spherically symmetric relativistic expansion. The light curves and the spectra from transparency of an electron-positron-photon plasma are obtained. We compare our results with the work of Goodman.
2016-11-01
a few nanoseconds. The challenge remains to diagnose plasmas via the free electron density in this short window of time and often in a small volume ...Free Electron Density in Laser-Produced Plasmas by Anthony R Valenzuela Approved for public release; distribution is...US Army Research Laboratory Shack-Hartmann Electron Densitometer (SHED): An Optical System for Diagnosing Free Electron Density in Laser
An enhanced tokamak startup model
NASA Astrophysics Data System (ADS)
Goswami, Rajiv; Artaud, Jean-François
2017-01-01
The startup of tokamaks has been examined in the past in varying degree of detail. This phase typically involves the burnthrough of impurities and the subsequent rampup of plasma current. A zero-dimensional (0D) model is most widely used where the time evolution of volume averaged quantities determines the detailed balance between the input and loss of particle and power. But, being a 0D setup, these studies do not take into consideration the co-evolution of plasma size and shape, and instead assume an unchanging minor and major radius. However, it is known that the plasma position and its minor radius can change appreciably as the plasma evolves in time to fill in the entire available volume. In this paper, an enhanced model for the tokamak startup is introduced, which for the first time takes into account the evolution of plasma geometry during this brief but highly dynamic period by including realistic one-dimensional (1D) effects within the broad 0D framework. In addition the effect of runaway electrons (REs) has also been incorporated. The paper demonstrates that the inclusion of plasma cross section evolution in conjunction with REs plays an important role in the formation and development of tokamak startup. The model is benchmarked against experimental results from ADITYA tokamak.
Verdecchia, Nicole M; Wisniewski, Mary Kay; Waters, Jonathan H; Triulzi, Darrell J; Alarcon, Louis H; Yazer, Mark H
2016-09-01
To analyze changes in red blood cell (RBC), platelet (PLT), and plasma transfusion volumes 9 years after the implementation of a multifaceted patient blood management (PBM) program across multiple hospitals. Between fiscal years 2007 and 2015, the annual transfusion volumes for seven hospitals in a regional healthcare system were analyzed by hospital, and between 2014 and 2015, by four service lines including emergency department, intensive care unit (ICU), medical/surgical ward, and operating room at each hospital. The number of units of RBCs administered to transfused recipients on the wards and in ICUs was also enumerated. For these seven hospitals combined, there was a 29.9% reduction in the number of RBCs transfused between 2007 and 2015, a 24.8% reduction in plasma units, and a 25.7% reduction in PLT units. The two largest hospitals saw some of the largest reductions in RBC transfusions (40.1, 25.1%), and plasma transfusions (26.1, 33.8%), and one of those hospitals had a 49.5% reduction in PLT transfusions. Smaller-sized hospitals also had reductions in transfusion volumes, while some volumes increased at hospitals when new or expanded clinical services were introduced. The number of RBC units per transfused recipient was generally between 1.5 and 2 units on the wards and slightly higher in the ICUs. Although the overall volume of transfusions has generally decreased at each hospital site over time, the appropriateness of the administered transfusions cannot be evaluated by these data. The system-wide implementation of a PBM program has reduced transfusion volumes.
Boertien, Wendy E; Meijer, Esther; Li, Jie; Bost, James E; Struck, Joachim; Flessner, Michael F; Gansevoort, Ron T; Torres, Vicente E
2013-03-01
Experimental studies indicate that arginine vasopressin (AVP) may have deleterious effects in the pathogenesis of autosomal dominant polycystic kidney disease (ADPKD). However, the significance of AVP in human ADPKD is unclear. Longitudinal observational study with 8.5 (IQR, 7.7-9.0) years' follow-up (CRISP [Consortium for Radiologic Imaging Studies of Polycystic Kidney Disease]). 241 patients with ADPKD with creatinine clearance >70 mL/min. Plasma copeptin concentration, a surrogate marker for AVP. Change in measured glomerular filtration rate (mGFR, assessed by iothalamate clearance) and total kidney volume (measured by magnetic resonance imaging). Baseline copeptin level, plasma and urinary osmolality, and measurements of total kidney volume and mGFR during follow-up. In these patients (median age, 34 [IQR, 25-40] years; 38% men; median mGFR, 94 [IQR, 79-145] mL/min/1.73 m(2); median total kidney volume, 859 [IQR, 577-1,299] mL), median copeptin level was 2.9 (IQR, 1.8-5.1) pmol/L. Copeptin was not associated with plasma osmolality (P = 0.3), the physiologic stimulus for AVP release, but was associated significantly with change in total kidney volume during follow-up (P < 0.001). This association remained significant after adjusting for sex, age, cardiovascular risk factors, and diuretic use (P = 0.03). Copeptin level was associated borderline significantly with change in mGFR after adjusting for these variables (P = 0.09). No standardization of hydration status at time of copeptin measurement. These data show that in ADPKD, copeptin level, as a marker for AVP, is not correlated with plasma osmolality. Most importantly, high copeptin levels are associated independently with disease progression in early ADPKD. This is in line with experimental studies that indicate a disease-promoting role for AVP. Copyright © 2013 National Kidney Foundation, Inc. All rights reserved.
Sources of error in determinations of carnitine and acylcarnitine in plasma.
Fishlock, R C; Bieber, L L; Snoswell, A M
1984-02-01
Radioactive and nonradioactive L-carnitine and acyl-L-carnitine were used to evaluate the washing procedures used during the determination of free, total, short-chain, and long-chain acylcarnitine in human and sheep plasma. The volume of fluid trapped by the protein precipitated by perchloric acid is approximately 24% of the total fluid volume and thus contains 24% of free carnitine and short-chain acylcarnitine. Washing twice with distilled water removes about 25% of the long-chain acylcarnitine along with the trapped free carnitine and short-chain acylcarnitines. Washing the pellet twice with a 60 g/L solution of perchloric acid completely removes the trapped free carnitine and short-chain acylcarnitine but does not remove the bound long-chain acylcarnitines. Thus washing with perchloric acid is essential for accurate measurement of long-chain acylcarnitines in plasma samples.
Electro-mechanical probe positioning system for large volume plasma device
NASA Astrophysics Data System (ADS)
Sanyasi, A. K.; Sugandhi, R.; Srivastava, P. K.; Srivastav, Prabhakar; Awasthi, L. M.
2018-05-01
An automated electro-mechanical system for the positioning of plasma diagnostics has been designed and implemented in a Large Volume Plasma Device (LVPD). The system consists of 12 electro-mechanical assemblies, which are orchestrated using the Modbus communication protocol on 4-wire RS485 communications to meet the experimental requirements. Each assembly has a lead screw-based mechanical structure, Wilson feed-through-based vacuum interface, bipolar stepper motor, micro-controller-based stepper drive, and optical encoder for online positioning correction of probes. The novelty of the system lies in the orchestration of multiple drives on a single interface, fabrication and installation of the system for a large experimental device like the LVPD, in-house developed software, and adopted architectural practices. The paper discusses the design, description of hardware and software interfaces, and performance results in LVPD.
Three-dimensional imaging of the ultracold plasma formed in a supersonic molecular beam
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schulz-Weiling, Markus; Grant, Edward
Double-resonant excitation of nitric oxide in a seeded supersonic molecular beam forms a state-selected Rydberg gas that evolves to form an ultracold plasma. This plasma travels with the propagation of the molecular beam in z over a variable distance as great as 600 mm to strike an imaging detector, which records the charge distribution in the dimensions, x and y. The ω{sub 1} + ω{sub 2} laser crossed molecular beam excitation geometry convolutes the axial Gaussian distribution of NO in the molecular beam with the Gaussian intensity distribution of the perpendicularly aligned laser beam to create an ellipsoidal volume of Rydbergmore » gas. Detected images describe the evolution of this initial density as a function of selected Rydberg gas initial principal quantum number, n{sub 0}, ω{sub 1} laser pulse energy (linearly related to Rydberg gas density, ρ{sub 0}) and flight time. Low-density Rydberg gases of lower principal quantum number produce uniformly expanding, ellipsoidal charge-density distributions. Increase either of n{sub 0} or ρ{sub 0} breaks the ellipsoidal symmetry of plasma expansion. The volume bifurcates to form repelling plasma volumes. The velocity of separation depends on n{sub 0} and ρ{sub 0} in a way that scales uniformly with ρ{sub e}, the density of electrons formed in the core of the Rydberg gas by prompt Penning ionization. Conditions under which this electron gas drives expansion in the long axis dimension of the ellipsoid favours the formation of counter-propagating shock waves.« less
Quantification of air plasma chemistry for surface disinfection
NASA Astrophysics Data System (ADS)
Pavlovich, Matthew J.; Clark, Douglas S.; Graves, David B.
2014-12-01
Atmospheric-pressure air plasmas, created by a variety of discharges, are promising sources of reactive species for the emerging field of plasma biotechnology because of their convenience and ability to operate at ambient conditions. One biological application of ambient-air plasma is microbial disinfection, and the ability of air plasmas to decontaminate both solid surfaces and liquid volumes has been thoroughly established in the literature. However, the mechanism of disinfection and which reactive species most strongly correlate with antimicrobial effects are still not well understood. We describe quantitative gas-phase measurements of plasma chemistry via infrared spectroscopy in confined volumes, focusing on air plasma generated via surface micro-discharge (SMD). Previously, it has been shown that gaseous chemistry is highly sensitive to operating conditions, and the measurements we describe here extend those findings. We quantify the gaseous concentrations of ozone (O3) and nitrogen oxides (NO and NO2, or NOx) throughout the established ‘regimes’ for SMD air plasma chemistry: the low-power, ozone-dominated mode; the high-power, nitrogen oxides-dominated mode; and the intermediate, unstable transition region. The results presented here are in good agreement with previously published experimental studies of aqueous chemistry and parameterized models of gaseous chemistry. The principal finding of the present study is the correlation of bacterial inactivation on dry surfaces with gaseous chemistry across these time and power regimes. Bacterial decontamination is most effective in ‘NOx mode’ and less effective in ‘ozone mode’, with the weakest antibacterial effects in the transition region. Our results underscore the dynamic nature of air plasma chemistry and the importance of careful chemical characterization of plasma devices intended for biological applications.
Atmospheric Pressure Glow Discharge for Point-of-Use Water Treatment
NASA Astrophysics Data System (ADS)
Lindsay, Alexander; Byrns, Brandon; Shannon, Steven; Knappe, Detlef
2012-10-01
Treatment of biological and chemical contaminants is an area of growing global interest where atmospheric pressure plasmas can make a significant contribution. Addressing key challenges of volume processing and operational cost, a large volume 162 MHz coaxial air-plasma source has been developed.footnotetextByrns (2012) J. Phys. D: Appl. Phys. 45 (2012) 195204 Because of VHF ballasting effects, the electric discharge is maintained at a steady glow, allowing formation of critical non-equilibrium chemistry. High densities, ne = 10^11-10^12, have been recorded. The atmospheric nature of the device permits straightforward and efficient treatment of water samples. [H^+] concentrations in 150 milliliter tap water samples have been shown to increase by 10^5 after five minutes of discharge exposure. Recent literature has demonstrated that increasing acidity is strongly correlated with a solution's ability to deactivate microbial contaminants.footnotetextTraylor (2011) J. Phys. D: Appl. Phys. 44 (2011) 472001 The work presented here will explore the impact of treatment gas, system configuration, and power density on water disinfection and PFC abatement. An array of plasma diagnostics, including OES and electrical measurements, are combined with post-process water analysis, including GC-MS and QT analysis of coliform and E.coli bacteria. Development of volume processing atmospheric plasma disinfection methods offers promise for point-of-use treatments in developing areas of the world, potentially supplementing or replacing supply and weather-dependent disinfection methods.
3D magnetospheric parallel hybrid multi-grid method applied to planet–plasma interactions
DOE Office of Scientific and Technical Information (OSTI.GOV)
Leclercq, L., E-mail: ludivine.leclercq@latmos.ipsl.fr; Modolo, R., E-mail: ronan.modolo@latmos.ipsl.fr; Leblanc, F.
2016-03-15
We present a new method to exploit multiple refinement levels within a 3D parallel hybrid model, developed to study planet–plasma interactions. This model is based on the hybrid formalism: ions are kinetically treated whereas electrons are considered as a inertia-less fluid. Generally, ions are represented by numerical particles whose size equals the volume of the cells. Particles that leave a coarse grid subsequently entering a refined region are split into particles whose volume corresponds to the volume of the refined cells. The number of refined particles created from a coarse particle depends on the grid refinement rate. In order tomore » conserve velocity distribution functions and to avoid calculations of average velocities, particles are not coalesced. Moreover, to ensure the constancy of particles' shape function sizes, the hybrid method is adapted to allow refined particles to move within a coarse region. Another innovation of this approach is the method developed to compute grid moments at interfaces between two refinement levels. Indeed, the hybrid method is adapted to accurately account for the special grid structure at the interfaces, avoiding any overlapping grid considerations. Some fundamental test runs were performed to validate our approach (e.g. quiet plasma flow, Alfven wave propagation). Lastly, we also show a planetary application of the model, simulating the interaction between Jupiter's moon Ganymede and the Jovian plasma.« less
Renal effects of carprofen and etodolac in euvolemic and volume-depleted dogs.
Surdyk, Kathryn K; Sloan, Dawn L; Brown, Scott A
2012-09-01
To determine the effects of carprofen and etodolac on renal function in euvolemic dogs and dogs with extracellular fluid volume depletion induced via administration of furosemide. 12 female Beagles. Dogs received a placebo, furosemide, carprofen, etodolac, furosemide and carprofen, and furosemide and etodolac. The order in which dogs received treatments was determined via a randomization procedure. Values of urine specific gravity, various plasma biochemical variables, glomerular filtration rate (GFR [urinary clearance of creatinine]), and renal plasma flow (urinary clearance of para-aminohippuric acid) were determined before and after 8 days of drug administration. A washout time of approximately 12 days was allowed between treatment periods. Administration of furosemide, furosemide and carprofen, and furosemide and etodolac caused changes in urine specific gravity and values of plasma biochemical variables. Administration of carprofen or etodolac alone did not have a significant effect on renal plasma flow or GFR. Concurrent administration of furosemide and carprofen or furosemide and etodolac caused a significant decrease in GFR. After 12-day washout periods, mean values of GFR were similar to values before drug administration for all treatments. Results indicated GFR decreased after 8 days of concurrent administration of furosemide and carprofen or furosemide and etodolac to dogs. Administration of preferential cyclooxygenase-2 inhibitors to dogs with extracellular fluid volume depletion or to dogs treated with diuretics may transiently impair renal function.
Demers, D R; Chen, X; Schoch, P M; Fimognari, P J
2010-10-01
Operation of a heavy ion beam probe (HIBP) on a reversed field pinch is unique from other toroidal applications because the magnetic field is more temporal and largely produced by plasma current. Improved confinement, produced through the transient application of a poloidal electric field which leads to a reduction of dynamo activity, exhibits gradual changes in equilibrium plasma quantities. A consequence of this is sweeping of the HIBP trajectories by the dynamic magnetic field, resulting in motion of the sample volume. In addition, the plasma potential evolves with the magnetic equilibrium. Measurement of the potential as a function of time is thus a combination of temporal changes of the equilibrium and motion of the sample volume. A frequent additional complication is a nonideal balance of ion current on the detectors resulting from changes in the beam trajectory (magnetic field) and energy (plasma potential). This necessitates use of data selection criteria. Nevertheless, the HIBP on the Madison Symmetric Torus has acquired measurements as a function of time throughout improved confinement. A technique developed to infer the potential in the improved confinement reversed field pinch from HIBP data in light of the time varying plasma equilibrium will be discussed.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vera, D.R.; Woodle, E.S.; Stadalnik, R.C.
1989-09-01
Kinetic sensitivity is the ability of a physiochemical parameter to alter the time-activity curve of a radiotracer. The kinetic sensitivity of liver and blood time-activity data resulting from a single bolus injection of ({sup 99m}Tc)galactosyl-neoglycoalbumin (( Tc)NGA) into healthy pigs was examined. Three parameters, hepatic plasma flow scaled as flow per plasma volume, ligand-receptor affinity, and total receptor concentration, were tested using (Tc)NGA injections of various molar doses and affinities. Simultaneous measurements of plasma volume (iodine-125 human serum albumin dilution), and hepatic plasma flow (indocyanine green extraction) were performed during 12 (Tc)NGA studies. Paired data sets demonstrated differences (P(chi v2)more » less than 0.01) in liver and blood time-activity curves in response to changes in each of the tested parameters. We conclude that the (Tc)NGA radiopharmacokinetic system is therefore sensitive to hepatic plasma flow, ligand-receptor affinity, and receptor concentration. In vivo demonstration of kinetic sensitivity permits delineation of the physiologic parameters that determine the biodistribution of a radiopharmaceutical. This delineation is a prerequisite to a valid analytic assessment of receptor biochemistry via kinetic modeling.« less
Surface Dielectric Barrier Discharge Jet for Skin Disinfection
NASA Astrophysics Data System (ADS)
Creyghton, Yves; Meijer, Rogier; Verweij, Paul; van der Zanden, Frank; Leenders, Paul
A consortium consisting of the research institute TNO, the medical university and hospital St Radboud and two industrial enterprises is working on a non-thermal plasma treatment method for hand disinfection. The group is seeking for cooperation, in particular in the field of validation methods and potential standardization for plasma based disinfection procedures. The present paper describes technical progress in plasma source development together with initial microbiological data. Particular properties of the sheet shaped plasma volume are the possibility of treating large irregular surfaces in a short period of time, effective plasma produced species transfer to the surface together with high controllability of the nature of plasma species by means of temperature conditioning.
NASA Astrophysics Data System (ADS)
Voitenko, D. A.; Ananyev, S. S.; Astapenko, G. I.; Basilaia, A. D.; Markolia, A. I.; Mitrofanov, K. N.; Myalton, V. V.; Timoshenko, A. P.; Kharrasov, A. M.; Krauz, V. I.
2017-12-01
Results are presented from experimental studies of the plasma flows generated in the KPF-4 Phoenix Mather-type plasma focus device (Sukhum Physical Technical Institute). In order to study how the formation and dynamics of the plasma flow depend on the initial distribution of the working gas, a system of pulsed gas puffing into the discharge volume was developed. The system allows one to create profiled gas distributions, including those with a reduced gas density in the region of plasma flow propagation. Results of measurements of the magnetic field, flow profile, and flow deceleration dynamics at different initial distributions of the gas pressure are presented.
Takei, Y
2000-04-01
The origin of life took place in the ancient sea where the ionic concentration is thought to have been somewhat lower than that of the present day seas. This may partly explain why most vertebrate species have plasma ionic concentrations roughly one-third of seawater. Exceptions are primitive marine cyclostomes whose plasma is almost identical to seawater, and marine cartilaginous fishes that accumulate urea in plasma to increase osmolarity to a seawater level. The mechanisms for regulation of water and electrolyte balance should have evolved from these animals into those of more advanced ones in which plasma ions are regulated to one-third of seawater irrespective of the habitat. Although most extant terrestrial and aquatic animals maintain similar plasma osmolarity and ionic concentrations, the mechanisms of regulation differ greatly among different groups of animals according to their habitat. An outstanding difference is that while plasma Na(+) concentration is a primary factor of regulation in terrestrial mammals and birds, blood volume is most strictly regulated in aquatic teleost fishes. Consistently, while an increase in plasma osmolarity (cellular dehydration) is a major dipsogenic stimulus for birds and mammals, hypovolemia (extracellular dehydration) is a much stronger stimulus for elicitation of drinking in teleost fishes. Furthermore, fish cells in culture are tolerant to changes in environmental osmolarity compared with mammalian cells, further suggesting a secondary role of plasma osmolarity as a target of regulation in fishes. A secondary role of blood volume for body fluid regulation in birds is further assessed by the fact that volume receptors for thirst, salt gland secretion, and vasotocin secretion are localized in the extravascular, interstitial space in some species of birds. All terrestrial animals including mammals have derived from the fishes in phylogeny, during which the mechanisms for body fluid regulation underwent adaptive evolution in the course of transition from aquatic to terrestrial life. Therefore, much can be learned from comparative studies of body fluid regulation that reveals the diversity and uniformity of the mechanisms. In this review, important comparative studies that may contribute to an understanding of body fluid regulation throughout vertebrate species will be summarized.
Measuring the equations of state in a relaxed magnetohydrodynamic plasma.
Kaur, M; Barbano, L J; Suen-Lewis, E M; Shrock, J E; Light, A D; Brown, M R; Schaffner, D A
2018-01-01
We report measurements of the equations of state of a fully relaxed magnetohydrodynamic (MHD) laboratory plasma. Parcels of magnetized plasma, called Taylor states, are formed in a coaxial magnetized plasma gun, and are allowed to relax and drift into a closed flux conserving volume. Density, ion temperature, and magnetic field are measured as a function of time as the Taylor states compress and heat. The theoretically predicted MHD and double adiabatic equations of state are compared to experimental measurements. We find that the MHD equation of state is inconsistent with our data.
Measuring the equations of state in a relaxed magnetohydrodynamic plasma
NASA Astrophysics Data System (ADS)
Kaur, M.; Barbano, L. J.; Suen-Lewis, E. M.; Shrock, J. E.; Light, A. D.; Brown, M. R.; Schaffner, D. A.
2018-01-01
We report measurements of the equations of state of a fully relaxed magnetohydrodynamic (MHD) laboratory plasma. Parcels of magnetized plasma, called Taylor states, are formed in a coaxial magnetized plasma gun, and are allowed to relax and drift into a closed flux conserving volume. Density, ion temperature, and magnetic field are measured as a function of time as the Taylor states compress and heat. The theoretically predicted MHD and double adiabatic equations of state are compared to experimental measurements. We find that the MHD equation of state is inconsistent with our data.
Renal function in juvenile rats subjected to prenatal malnutrition and chronic salt overload.
Magalhães, João Carlos G; da Silveira, Alex B; Mota, Diogenes L; Paixão, Ana Durce O
2006-05-01
Dietary sodium may contribute to hypertension and to cardiovascular and renal disease if a primary deficiency of the kidney to excrete sodium exists. In order to investigate whether chronic 1% NaCl in the drinking water changes blood pressure and renal haemodynamics in juvenile Wistar rats subjected to prenatal malnutrition, an evaluation of plasma volume, oxidative stress in the kidney, proteinuria and renal haemodynamics was carried out. Malnutrition was induced by a multideficient diet. Mean arterial pressure, renal blood flow and glomerular filtration rate (GFR) were measured using a blood pressure transducer, a flow probe and inulin clearance, respectively. Plasma volume and oxidative stress were measured by means of the Evans Blue method and by monitoring thiobarbituric acid reactive substances (TBARS) in the kidneys, respectively. Urinary protein was measured by precipitation with 3% sulphosalicylic acid. It was observed that prenatally malnourished rats presented higher values of plasma volume (26%, P < 0.05), kidney TBARS (43%, P < 0.01) and blood pressure (10%, P < 0.01) when compared with the control group. However, they showed no change in renal haemodynamics or proteinuria. Neither prenatally malnourished nor control rats treated with sodium overload presented plasma volume or blood pressure values different from their respective control groups, but both groups presented elevated proteinuria (P < 0.01). The prenatally malnourished group treated with sodium overload presented higher values of kidney TBARS, GFR and filtration fraction (58, 87 and 72% higher, respectively, P < 0.01) than its respective control group. In summary, sodium overload did not exacerbate the hypertension in juvenile prenatally malnourished rats, but induced renal haemodynamic adjustments compatible with the development of renal disease.
Glycerol-induced hyperhydration
NASA Technical Reports Server (NTRS)
Riedesel, Marvin L.; Lyons, Timothy P.; Mcnamara, M. Colleen
1991-01-01
Maintenance of euhydration is essential for maximum work performance. Environments which induce hypohydration reduce plasma volume and cardiovascular performance progressively declines as does work capacity. Hyperhydration prior to exposure to dehydrating environments appears to be a potential countermeasure to the debilitating effects of hypohydration. The extravascular fluid space, being the largest fluid compartment in the body, is the most logical space by which significant hyperhydration can be accomplished. Volume and osmotic receptors in the vascular space result in physiological responses which counteract hyperhydration. Our hypothesis is that glycerol-induced hyperhydration (GIH) can accomplish extravascular fluid expansion because of the high solubility of glycerol in lipid and aqueous media. A hypertonic solution of glycerol is rapidly absorbed from the gastrointestinal tract, results in mild increases in plasma osmolality and is distributed to 65 percent of the body mass. A large volume of water ingested within minutes after glycerol intake results in increased total body water because of the osmotic action and distribution of glycerol. The resulting expanded extravascular fluid space can act as a reservoir to maintain plasma volume during exposure to dehydrating environments. The fluid shifts associated with exposure to microgravity result in increased urine production and is another example of an environment which induces hypohydration. Our goal is to demonstrate that GIH will facilitate maintenance of euhydration and cardiovascular performance during space flight and upon return to a 1 g environment.
Metrics for comparing plasma mass filters
NASA Astrophysics Data System (ADS)
Fetterman, Abraham J.; Fisch, Nathaniel J.
2011-10-01
High-throughput mass separation of nuclear waste may be useful for optimal storage, disposal, or environmental remediation. The most dangerous part of nuclear waste is the fission product, which produces most of the heat and medium-term radiation. Plasmas are well-suited to separating nuclear waste because they can separate many different species in a single step. A number of plasma devices have been designed for such mass separation, but there has been no standardized comparison between these devices. We define a standard metric, the separative power per unit volume, and derive it for three different plasma mass filters: the plasma centrifuge, Ohkawa filter, and the magnetic centrifugal mass filter.
Electromagnetic radiation from beam-plasma instabilities
NASA Technical Reports Server (NTRS)
Stenzel, R. L.; Whelan, D. A.
1982-01-01
The mechanism by which unstable electrostatic waves of an electron-beam plasma system are converted into observed electromagnetic waves is of great current interest in space plasma physics. Electromagnetic radiation arises from both natural beam-plasma systems, e.g., type III solar bursts and kilometric radiation, and from man-made electron beams injected from rockets and spacecraft. In the present investigation the diagnostic difficulties encountered in space plasmas are overcome by using a large laboratory plasma. A finite diameter (d approximately equal to 0.8 cm) electron beam is injected into a uniform quiescent magnetized afterglow plasma of dimensions large compared with electromagnetic wavelength. Electrostatic waves grow, saturate and decay within the uniform central region of the plasma volume so that linear mode conversion on density gradients can be excluded as a possible generation mechanism for electromagnetic waves.
Changes in body fluid compartments on re-induction to high altitude and effect of diuretics
NASA Astrophysics Data System (ADS)
Singh, M. V.; Rawal, S. B.; Tyagi, A. K.; Bhagat, Maj J. K.; Parshad, R.; Divekar, H. M.
1988-03-01
Studies were carried out in 29 healthy young adults in the Indian Army stationed in the plains and posted at an elevation of 3500 m for more than 6 months. After exposure to a low elevation in Delhi (260 m) for 3 weeks they were reinduced to a height of 3500 m. The subjects were divided into three groups, each of which was treated with either placebo or acetazolamide or spironolactone. The drug treatment was started immediately after their landing at high altitude and continued for 2 days only. Total body water, extracellular fluid, intracellular fluid, plasma volume, blood pH, PaO2, PaCO2 and blood viscosity were determined on exposure at Delhi and on re-induction to high altitude. Plasma volume was increased after the descent from high altitude and remained high for up to 21 day's study. This increased plasma volume may have some significance in the pathogenesis of pulmonary oedema. Total body water and intracellular fluid content were increased at 260 m elevation, while extracellular fluid decreased. On re-induction there was a decrease in total body water with no change in the extracellular fluid content.
Effect of carbohydrate composition on fluid balance, gastric emptying, and exercise performance.
Cole, K J; Grandjean, P W; Sobszak, R J; Mitchell, J B
1993-12-01
This study examined the effects of serial feedings of different carbohydrate (CHO) solutions on plasma volume, gastric emptying (GE), and performance during prolonged cycling exercise. Solutions containing 6 g% glucose-sucrose (CHO-6GS), 8.3 g% high fructose corn syrup (CHO-8HF), 6.3 g% high fructose corn syrup + 2 g% glucose polymer (CHO-8HP), and a water placebo (WP) were compared. Ten trained male cyclists performed four cycling trials consisting of 105 min at 70% VO2max followed by a 15-min all-out, self-paced performance ride. Every 15 min the men consumed one of the four test solutions. Blood samples were taken before, during, and after exercise to determine blood glucose and plasma volume changes. There were no significant differences in performance, GE, or plasma volume changes between trials. Blood glucose was significantly elevated at the 105-min time-point in all CHO trials when compared to WP. The CHO-8HF and CHO-8HP drinks resulted in a significantly higher delivery of CHO to the intestine. Higher rates of CHO oxidation during the steady-state ride were observed only with the CHO-6GS drink.
González Montoro, Ayelén; Bigliani, Gonzalo; Valdez Taubas, Javier
2017-11-15
Endocytosis is crucial for all cells as it allows them to incorporate material from the extracellular space and control the availability of transmembrane proteins at the plasma membrane. In yeast, endocytosis followed by recycling to the plasma membrane results in a polarised distribution of membrane proteins by a kinetic mechanism. Here, we report that increasing the volume of residues that constitute the exoplasmic half of the transmembrane domain (TMD) in the yeast SNARE Sso1, a type II membrane protein, results in its polarised distribution at the plasma membrane. Expression of this chimera in strains affected in either endocytosis or recycling revealed that this polarisation is achieved by endocytic cycling. A bioinformatics search of the Saccharomyces cerevisiae proteome identified several proteins with high-volume exoplasmic hemi-TMDs. Our experiments indicate that TMDs from these proteins can confer a polarised distribution to the Sso1 cytoplasmic domain, indicating that the shape of the TMD can act as a novel endocytosis and polarity signal in yeast . Additionally, a high-volume exoplasmic hemi-TMD can act as an endocytosis signal in a mammalian cell line. © 2017. Published by The Company of Biologists Ltd.
Effect of sauna bathing and beer ingestion on plasma concentrations of purine bases.
Yamamoto, Tetsuya; Moriwaki, Yuji; Ka, Tuneyoshi; Takahashi, Sumio; Tsutsumi, Zenta; Cheng, Jidong; Inokuchi, Taku; Yamamoto, Asako; Hada, Toshikazu
2004-06-01
To determine whether sauna bathing alone or in combination with beer ingestion increases the plasma concentration of uric acid, 5 healthy subjects were tested. Urine and plasma measurements were performed before and after each took a sauna bath, ingested beer, and ingested beer just after taking a sauna bath, with a 2-week interval between each activity. Sauna bathing alone increased the plasma concentrations of uric acid and oxypurines (hypoxanthine and xanthine), and decreased the urinary and fractional excretion of uric acid, while beer ingestion alone increased the plasma concentrations and urinary excretion of uric acid and oxypurines. A combination of both increased the plasma concentration of uric acid and oxypurines, and decreased the urinary and fractional excretion of uric acid, with an increase in the urinary excretion of oxypurines. The increase in plasma concentration of uric acid with the combination protocol was not synergistic as compared to the sum of the increases by each alone. Body weight, urine volume, and the urinary excretion of sodium and chloride via dehydration were decreased following sauna bathing alone. These results suggest that sauna bathing had a relationship with enhanced purine degradation and a decrease in the urinary excretion of uric acid, leading to an increase in the plasma concentration of uric acid. Further, we concluded that extracellular volume loss may affect the common renal transport pathway of uric acid and xanthine. Therefore, it is recommended that patients with gout refrain from drinking alcoholic beverages, including beer, after taking a sauna bath, since the increase in plasma concentration of uric acid following the combination of sauna bathing and beer ingestion was additive.
Ferreira-Gonzalez, A; Yanovich, S; Langley, M R; Weymouth, L A; Wilkinson, D S; Garrett, C T
2000-01-01
Accurate and rapid diagnosis of CMV disease in immunocompromised individuals remains a challenge. Quantitative polymerase chain reaction (QPCR) methods for detection of CMV in peripheral blood mononuclear cells (PBMC) have improved the positive and negative predictive value of PCR for diagnosis of CMV disease. However, detection of CMV in plasma has demonstrated a lower negative predictive value for plasma as compared with PBMC. To enhance the sensitivity of the QPCR assay for plasma specimens, plasma samples were centrifuged before nucleic-acid extraction and the extracted DNA resolubilized in reduced volume. Optimization of the nucleic-acid extraction focused on decreasing or eliminating the presence of inhibitors in the pelleted plasma. Quantitation was achieved by co-amplifying an internal quantitative standard (IS) with the same primer sequences as CMV. PCR products were detected by hybridization in a 96-well microtiter plate coated with a CMV or IS specific probe. The precision of the QPCR assay for samples prepared from untreated and from pelleted plasma was then assessed. The coefficient of variation for both types of samples was almost identical and the magnitude of the coefficient of variations was reduced by a factor of ten if the data were log transformed. Linearity of the QPCR assay extended over a 3.3-log range for both types of samples but the range of linearity for pelleted plasma was 20 to 40,000 viral copies/ml (vc/ml) in contrast to 300 to 400,000 vc/ml for plasma. Thus, centrifugation of plasma before nucleic-acid extraction and resuspension of extracted CMV DNA in reduced volume enhanced the analytical sensitivity approximately tenfold over the dynamic range of the assay. Copyright 2000 Wiley-Liss, Inc.
Plasma Amyloid-β Levels, Cerebral Small Vessel Disease, and Cognition: The Rotterdam Study.
Hilal, Saima; Akoudad, Saloua; van Duijn, Cornelia M; Niessen, Wiro J; Verbeek, Marcel M; Vanderstichele, Hugo; Stoops, Erik; Ikram, M Arfan; Vernooij, Meike W
2017-01-01
Plasma amyloid-β (Aβ) levels are increasingly studied as a potential, accessible marker of cognitive impairment and dementia. The most common plasma Aβ isoforms, i.e., Aβ1-40 and Aβ1-42 have been linked with risk of Alzheimer's disease. However, it remains under-explored whether plasma Aβ levels including novel Aβ1-38 relate to vascular brain disease and cognition in a preclinical-phase of dementiaObjective:To examine the association of plasma Aβ levels (i.e., Aβ1-38, Aβ1-40, and Aβ1-42) with markers of cerebral small vessel disease (SVD) and cognition in a large population-based setting. We analyzed plasma Aβ1 levels in 1201 subjects from two independent cohorts of the Rotterdam Study. Markers of SVD [lacunes, white matter hyperintensity (WMH) volume] were assessed on brain MRI (1.5T). Cognition was assessed by a detailed neuropsychological battery. In each cohort, the association of Aβ levels with SVD and cognition was performed using regression models. Estimates were then pooled across cohorts using inverse variance meta-analysis with fixed effects. Higher levels of plasma Aβ1-38, Aβ1-40, Aβ1-42, and Aβ1-40/ Aβ1-42 ratio were associated with increasing lacunar and microbleeds counts. Moreover, higher levels of Aβ1-40 and Aβ1-40/ Aβ1-42 were significantly associated with larger WMH volumes. With regard to cognition, a higher level of Aβ1-38 Aβ1-40 and Aβ1-40/ Aβ1-42 was related to worse performance on cognitive test specifically in memory domain. Higher plasma levels of Aβ levels are associated with subclinical markers of vascular disease and poorer memory. Plasma Aβ levels thus mark the presence of vascular brain pathology.
Effect of standing on neurohumoral responses and plasma volume in healthy subjects
NASA Technical Reports Server (NTRS)
Jacob, G.; Ertl, A. C.; Shannon, J. R.; Furlan, R.; Robertson, R. M.; Robertson, D.
1998-01-01
Upright posture leads to rapid pooling of blood in the lower extremities and shifts plasma fluid into surrounding tissues. This results in a decrease in plasma volume (PV) and in hemoconcentration. There has been no integrative evaluation of concomitant neurohumoral and PV shifts with upright posture in normal subjects. We studied 10 healthy subjects after 3 days of stable Na+ and K+ intake. PV was assessed by the Evans blue dye method and by changes in hematocrit. Norepinephrine (NE), NE spillover, epinephrine (Epi), vasopressin, plasma renin activity, aldosterone, osmolarity, and kidney response expressed by urine osmolality and by Na+ and K+ excretion of the subjects in the supine and standing postures were all measured. We found that PV fell by 13% (375 +/- 35 ml plasma) over approximately 14 min, after which time it remained relatively stable. There was a concomitant decrease in systolic blood pressure and an increase in heart rate that peaked at the time of maximal decrease in PV. Plasma Epi and NE increased rapidly to this point. Epi approached baseline by 20 min of standing. NE spillover increased 80% and clearance decreased 30% with 30 min of standing. The increase in plasma renin activity correlated with an increase in aldosterone. Vasopressin increased progressively, but there was no change in plasma osmolarity. The kidney response showed a significant decrease in Na+ and an increase in K+ excretion with upright posture. We conclude that a cascade of neurohumoral events occurs with upright posture, some of which particularly coincide with the decrease in PV. Plasma Epi levels may contribute to the increment in heart rate with maintained upright posture.
Hemodynamic and neurohormonal responses to extreme orthostatic stress in physically fit young adults
NASA Astrophysics Data System (ADS)
Grasser, E. K.; Goswami, N.; Rössler, A.; Vrecko, K.; Hinghofer-Szalkay, H.
2009-04-01
Blood pressure stability may be jeopardized in astronauts experiencing orthostatic stress. There is disagreement about cardiovascular and endocrine stress responses that emerge when a critical (presyncopal) state is reached. We studied hemodynamic and neurohormonal changes as induced by an orthostatic stress paradigm (head-up tilt combined with lower body negative pressure) that leads to a syncopal endpoint. From supine control to presyncope, heart rate increased by 78% and thoracic impedance by 12%. There was a 49% fall in stroke volume index, 19% in mean arterial blood pressure, 14% in total peripheral resistance index and 11% in plasma volume. Plasma norepinephrine rose by 107, epinephrine by 491, plasma renin activity by 167, and cortisol by 25%. Hemodynamic and hormonal changes of clearly different magnitude emerge in presyncope as compared to supine rest. Additional studies are warranted to reveal the exact time course of orthostatic changes up to syncopal levels.
A 5 kA pulsed power supply for inductive and plasma loads in large volume plasma device.
Srivastava, P K; Singh, S K; Sanyasi, A K; Awasthi, L M; Mattoo, S K
2016-07-01
This paper describes 5 kA, 12 ms pulsed power supply for inductive load of Electron Energy Filter (EEF) in large volume plasma device. The power supply is based upon the principle of rapid sourcing of energy from the capacitor bank (2.8 F/200 V) by using a static switch, comprising of ten Insulated Gate Bipolar Transistors (IGBTs). A suitable mechanism is developed to ensure equal sharing of current and uniform power distribution during the operation of these IGBTs. Safe commutation of power to the EEF is ensured by the proper optimization of its components and by the introduction of over voltage protection (>6 kV) using an indigenously designed snubber circuit. Various time sequences relevant to different actions of power supply, viz., pulse width control and repetition rate, are realized through optically isolated computer controlled interface.
A 5 kA pulsed power supply for inductive and plasma loads in large volume plasma device
DOE Office of Scientific and Technical Information (OSTI.GOV)
Srivastava, P. K., E-mail: pkumar@ipr.res.in; Singh, S. K.; Sanyasi, A. K.
This paper describes 5 kA, 12 ms pulsed power supply for inductive load of Electron Energy Filter (EEF) in large volume plasma device. The power supply is based upon the principle of rapid sourcing of energy from the capacitor bank (2.8 F/200 V) by using a static switch, comprising of ten Insulated Gate Bipolar Transistors (IGBTs). A suitable mechanism is developed to ensure equal sharing of current and uniform power distribution during the operation of these IGBTs. Safe commutation of power to the EEF is ensured by the proper optimization of its components and by the introduction of over voltagemore » protection (>6 kV) using an indigenously designed snubber circuit. Various time sequences relevant to different actions of power supply, viz., pulse width control and repetition rate, are realized through optically isolated computer controlled interface.« less
Isochoric Heating of Solid-Density Matter with an Ultrafast Proton Beam
DOE Office of Scientific and Technical Information (OSTI.GOV)
Key, M H; Mackinnon, A J; Patel, P K
A new technique is described for the isochoric heating (i.e., heating at constant volume) of matter to high energy-density plasma states (>10{sup 5} J/g) on a picosecond timescale (10{sup -12} sec). An intense, collimated, ultrashort-pulse beam of protons--generated by a high-intensity laser pulse--is used to isochorically heat a solid density material to a temperature of several eV. The duration of heating is shorter than the timescale for significant hydrodynamic expansion to occur, hence the material is heated to a solid density warm dense plasma state. Using spherically-shaped laser targets a focused proton beam is produced and used to heat amore » smaller volume to over 20 eV. The technique described of ultrafast proton heating provides a unique method for creating isochorically heated high-energy density plasma states.« less
NASA Astrophysics Data System (ADS)
Mishra, Rinku; Dey, M.
2018-04-01
An analytical model is developed that explains the propagation of a high frequency electrostatic surface wave along the interface of a plasma system where semi-infinite electron-ion plasma is interfaced with semi-infinite dusty plasma. The model emphasizes that the source of such high frequency waves is inherent in the presence of ion acoustic and dust ion acoustic/dust acoustic volume waves in electron-ion plasma and dusty plasma region. Wave dispersion relation is obtained for two distinct cases and the role of plasma parameters on wave dispersion is analyzed in short and long wavelength limits. The normalized surface wave frequency is seen to grow linearly for lower wave number but becomes constant for higher wave numbers in both the cases. It is observed that the normalized frequency depends on ion plasma frequencies when dust oscillation frequency is neglected.
Application of nonlocal plasma technology for controlling plasma conductivity
NASA Astrophysics Data System (ADS)
Yuan, Chengxun; Demidov, V. I.; Kudryavtsev, A. A.; Kurlyandskaya, I. P.; Rudakova, T. V.; Zhou, Z. X.
2017-10-01
A promising approach for better control of the plasma parameters involves the exploitation of peculiarities of plasmas with a nonlocal electron energy distribution. Nonlocal plasma technology (NLP-technology) is based on the effect of energetic electrons in the plasma volume. In this work, an experimental study of influence of the chemo-ionization processes on non-stationary plasma conductivity has been conducted. Due to energetic, supra-thermal electrons, which appear in the chemo-ionization reactions, the highly non-equilibrium and time dependent nonlocal electron energy distribution function is formed. In such a plasma thermal electrons always have positive conductivity (mobility), while supra-thermal, energetic electrons may have negative conductivity in heavy (argon, krypton and xenon) noble gases dependently on conditions. Experiments demonstrate that this effect may lead to the non-monotonic temporal behavior of plasma conductivity and may potentially create the negative electron mobility.
Amend, D.F.; Smith, L.
1975-01-01
Infectious hematopoietic necrosis (IHN) is a rhabdoviral disease of rainbow trout (Salmo gairdneri). Trout were injected with IHNV, and various hematological and biochemical measurements of clinically ill fish were compared to uninfected controls. Infected fish had reduced corpuscular counts, hemoglobin, and packed cell volume, but normal mean corpuscular volume, mean corpuscular hemoglobin, and mean corpuscular hemoglobin concentration. The percentage of immature erythrocytes was increased, but the percentage of leukocytes was unchanged. Differential leukocyte counts showed a significant decrease in neutrophils, increase in lymphocytes, but no change in monocytes. Unidentifiable necrobiotic cells were prevelant in blood smears and hematopoietic tissue imprints. Plasma bicarbonate, chloride, calcium, phosphorus, bilirubin, and osmolality were significantly reduced, but plasma glucose and anterior kidney ascorbate were unchanged. Plasma pH increased and the alpha fractions of the serum proteins were altered. No change was found in plasma enzymes, except that a LDH isozyme was significantly increased. The alkali reserve was diminished and alterations in acid-base and fluid balance occurred. Death probably resulted from a severe electrolyte and fluid imbalance caused by renal failure.
Destruction of inorganic municipal solid waste incinerator fly ash in a DC arc plasma furnace.
Zhao, Peng; Ni, Guohua; Jiang, Yiman; Chen, Longwei; Chen, Mingzhou; Meng, Yuedong
2010-09-15
Due to the toxicity of dioxins, furans and heavy metals, there is a growing environmental concern on municipal solid waste incinerator (MSWI) fly ash in China. The purpose of this study is directed towards the volume-reduction of fly ash without any additive by thermal plasma and recycling of vitrified slag. This process uses extremely high-temperature in an oxygen-starved environment to completely decompose complex waste into very simple molecules. For developing the proper plasma processes to treat MSWI fly ash, a new crucible-type plasma furnace was built. The melting process metamorphosed fly ash to granulated slag that was less than 1/3 of the volume of the fly ash, and about 64% of the weight of the fly ash. The safety of the vitrified slag was tested. The properties of the slag were affected by the differences in the cooling methods. Water-cooled and composite-cooled slag showed more excellent resistance against the leaching of heavy metals and can be utilized as building material without toxicity problems. Copyright 2010 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Cao, Zhitao; Jiang, Lan; Wang, Sumei; Wang, Mengmeng; Liu, Lei; Yang, Fan; Lu, Yongfeng
2018-03-01
Femtosecond laser pulse train induced breakdown of fused silica was studied by investigating its plasma emission and the ablated crater morphology. It was demonstrated that the electron dynamics in the ablated fused silica play a dominant role in the emission intensity of induced plasma and the volume of material removal, corresponding to the evolution of free-electron, self-trapped excitons, and the phase change of the fused silica left over by the first pulse. For a fluence of 11 J/cm2, the maximum plasma intensity of double-pulse irradiation at an interpulse delay of 120 ps was about 35 times stronger than that of a single-pulse, while the ablated crater was reduced by 27% in volume. The ionization of slow plume component generated by the first pulse was found to be the main reason for the extremely high intensity enhancement for an interpulse delay of over 10 ps. The results serve as a route to simultaneously increase the spatial resolution and plasma intensity in laser-induced breakdown spectroscopy of dielectrics.
Wang, Hanghang; Muehlbauer, Michael J.; O’Neal, Sara K.; Newgard, Christopher B.; Hauser, Elizabeth R.; Shah, Svati H.
2017-01-01
The field of metabolomics as applied to human disease and health is rapidly expanding. In recent efforts of metabolomics research, greater emphasis has been placed on quality control and method validation. In this study, we report an experience with quality control and a practical application of method validation. Specifically, we sought to identify and modify steps in gas chromatography-mass spectrometry (GC-MS)-based, non-targeted metabolomic profiling of human plasma that could influence metabolite identification and quantification. Our experimental design included two studies: (1) a limiting-dilution study, which investigated the effects of dilution on analyte identification and quantification; and (2) a concentration-specific study, which compared the optimal plasma extract volume established in the first study with the volume used in the current institutional protocol. We confirmed that contaminants, concentration, repeatability and intermediate precision are major factors influencing metabolite identification and quantification. In addition, we established methods for improved metabolite identification and quantification, which were summarized to provide recommendations for experimental design of GC-MS-based non-targeted profiling of human plasma. PMID:28841195
Optimal Design of Magnetic ComponentsinPlasma Cutting Power Supply
NASA Astrophysics Data System (ADS)
Jiang, J. F.; Zhu, B. R.; Zhao, W. N.; Yang, X. J.; Tang, H. J.
2017-10-01
Phase-shifted transformer and DC reactor are usually needed in chopper plasma cutting power supply. Because of high power rate, the loss of magnetic components may reach to several kilowatts, which seriously affects the conversion efficiency. Therefore, it is necessary to research and design low loss magnetic components by means of efficient magnetic materials and optimal design methods. The main task in this paper is to compare the core loss of different magnetic material, to analyze the influence of transformer structure, winding arrangement and wire structure on the characteristics of magnetic component. Then another task is to select suitable magnetic material, structure and wire in order to reduce the loss and volume of magnetic components. Based on the above outcome, the optimization design process of transformer and dc reactor are proposed in chopper plasma cutting power supply with a lot of solutions. These solutions are analyzed and compared before the determination of the optimal solution in order to reduce the volume and power loss of the two magnetic components and improve the conversion efficiency of plasma cutting power supply.
Study of negative ion transport phenomena in a plasma source
DOE Office of Scientific and Technical Information (OSTI.GOV)
Riz, D.; Pamela, J.
1996-07-01
NIETZSCHE (Negative Ions Extraction and Transport ZSimulation Code for HydrogEn species) is a negative ion (NI) transport code developed at Cadarache. This code calculates NI trajectories using a 3D Monte-Carlo technique, taking into account the main destruction processes, as well as elastic collisions (H{sup {minus}}/H{sup +}) and charge exchanges (H{sup {minus}}/H{sup 0}). It determines the extraction probability of a NI created at a given position. According to the simulations, we have seen that in the case of volume production, only NI produced close to the plasma grid (PG) can be extracted. Concerning the surface production, we have studied how NImore » produced on the PG and accelerated by the plasma sheath backward into the source could be extracted. We demonstrate that elastic collisions and charge exchanges play an important role, which in some conditions dominates the magnetic filter effect, which acts as a magnetic mirror. NI transport in various conditions will be discussed: volume/surface production, high/low plasmas density, tent filter/transverse filter. {copyright} {ital 1996 American Institute of Physics.}« less
Real-time monitoring and control of the plasma hearth process
DOE Office of Scientific and Technical Information (OSTI.GOV)
Power, M.A.; Carney, K.P.; Peters, G.G.
1996-05-01
A distributed monitoring and control system is proposed for a plasma hearth, which will be used to decompose hazardous organic materials, encapsulate actinide waste in an obsidian-like slag, and reduce storage volume of actinide waste. The plasma hearth will be installed at ANL-West with the assistance of SAIC. Real-time monitoring of the off-gas system is accomplished using a Sun Workstation and embedded PCs. LabWindows/CVI software serves as the graphical user interface.
Electrical Conductivity of Dense Al, Ti, Fe, Ni, Cu, Mo, Ta, and W Plasmas
2011-06-01
for all but tantalum and titanium shows a minimum at approximately 0.01 times solid density, followed by an increase as the density decreases further...internal energy and specific volume. Conductivity is observed to fall as the plasma expands for fixed internal energy, and for all but tantalum and...plasmas formed from elemental metal wires heated rapidly in a water bath by the electric current from discharge of a charged capacitor . Electrical
Synthesis of Silane and Silicon in a Non-equilibrium Plasma Jet
NASA Technical Reports Server (NTRS)
Calcote, H. F.
1978-01-01
The original objective of this program was to determine the feasibility of high volume, low-cost production of high purity silane or solar cell grade silicon using a non equilibrium plasma jet. The emphasis was changed near the end of the program to determine the feasibility of preparing photovoltaic amorphous silicon films directly using this method. The non equilibrium plasma jet should be further evaluated as a technique for producing high efficiency photovoltaic amorphous silicon films.
A Van der Waals-like theory of plasma double layers
NASA Technical Reports Server (NTRS)
Katz, Ira; Davis, V. A.
1989-01-01
A theory describing plasma double layers in terms of multiple roots of the charge density expression is presented. The theory presented uses the fact that equilibrium plasmas shield small potential perturbations linearly; for high potentials, the shielding decreases. The approach is analogous to Van der Waals' theory of simple fluids in which inclusion of approximate expressions for both excluded volume and long range attractive forces sufficiently describes the first-order liquid-gas phase transition.
Phan, Jenny-Ann; Landau, Anne M; Jakobsen, Steen; Wong, Dean F; Gjedde, Albert
2017-11-22
We describe a novel method of kinetic analysis of radioligand binding to neuroreceptors in brain in vivo, here applied to noradrenaline receptors in rat brain. The method uses positron emission tomography (PET) of [ 11 C]yohimbine binding in brain to quantify the density and affinity of α 2 adrenoceptors under condition of changing radioligand binding to plasma proteins. We obtained dynamic PET recordings from brain of Spraque Dawley rats at baseline, followed by pharmacological challenge with unlabeled yohimbine (0.3 mg/kg). The challenge with unlabeled ligand failed to diminish radioligand accumulation in brain tissue, due to the blocking of radioligand binding to plasma proteins that elevated the free fractions of the radioligand in plasma. We devised a method that graphically resolved the masking of unlabeled ligand binding by the increase of radioligand free fractions in plasma. The Extended Inhibition Plot introduced here yielded an estimate of the volume of distribution of non-displaceable ligand in brain tissue that increased with the increase of the free fraction of the radioligand in plasma. The resulting binding potentials of the radioligand declined by 50-60% in the presence of unlabeled ligand. The kinetic unmasking of inhibited binding reflected in the increase of the reference volume of distribution yielded estimates of receptor saturation consistent with the binding of unlabeled ligand.
Thimister, P W; Hopman, W P; Sloots, C E; Rosenbusch, G; Tangerman, A; Willems, H L; Lamers, C B; Jansen, J B
1994-12-01
Bombesin-stimulated plasma cholecystokinin levels decrease after an initial increase despite continuous infusion of bombesin. The aim of this study was to determine if a feedback mechanism, mediated by bile salts or proteolytic enzymes, is responsible for this decline. Bombesin (1.0 ng.kg-1.min-1) was infused into volunteers for 180 minutes on separate occasions. Cholestyramine, colestipol, camostate, or saline were perfused intraduodenally during the second hour of the tests. Cholestyramine was also administered without infusion of bombesin. Colestipol and cholestyramine, dependent on their bile salt-binding capacity, markedly enhanced (P < 0.05) bombesin-stimulated plasma cholecystokinin from 2.1 +/- 0.5 pmol/L to 6.4 +/- 2.2 pmol/L and 12.1 +/- 3.3 pmol/L (P < 0.05 vs. colestipol), respectively, and further decreased gallbladder volume (P < 0.05) from 9.4 +/- 1.6 mL to 2.0 +/- 0.4 mL and 2.2 +/- 0.5 mL, respectively. The protease inhibitor camostate had no effect. Bile salt precipitation also enhanced plasma pancreatic polypeptide responses (P < 0.01) but did not alter gastrin responses. Plasma cholecystokinin responses to cholestyramine without bombesin infusion varied considerably, but increments were highly correlated to decreases in gallbladder volume (r = 0.91; P < 0.005). Bile salt sequestration but not protease inactivation enhances plasma cholecystokinin and gallbladder responses to bombesin infusion in humans.
Controlling plasma distributions as driving forces for ion migration during fs laser writing
NASA Astrophysics Data System (ADS)
Teddy Fernandez, Toney; Siegel, Jan; Hoyo, Jesus; Sotillo, Belen; Fernandez, Paloma; Solis, Javier
2015-04-01
The properties of structures written inside dielectrics with high repetition rate femtosecond lasers are known to depend strongly on the complex interplay of a large number of writing parameters. Recently, ion migration within the laser-excited volume has been identified as a powerful mechanism for changing the local element distribution and producing efficient optical waveguides. In this work it is shown that the transient plasma distribution induced during laser irradiation is a reliable monitor for predicting the final refractive index distribution of the waveguide caused by ion migration. By performing in situ plasma emission microscopy during the writing process inside a La-phosphate glass it is found that the long axis of the plasma distribution determines the axis of ion migration, being responsible for the local refractive index increase. This observation is also valid when strong positive or negative spherical aberration is induced, greatly deforming the focal volume and inverting the index profile. Even subtle changes in the writing conditions, such as an inversion of the writing direction (quill writing effect), show up in the form of a modified plasma distribution, which manifests as a modified index distribution. Finally, it is shown that the superior control over the waveguide properties employing the slit shaping technique is caused by the more confined plasma distribution produced. The underlying reasons for this unexpected result are discussed in terms of non-linear propagation and heat accumulation.
Kussman, Barry D; Zurakowski, David; Sullivan, Lorna; McGowan, Francis X; Davis, Peter J; Laussen, Peter C
2005-06-01
The purpose of the study was to measure changes in plasma fentanyl concentrations during infant cardiac surgery using a bypass circuit with low priming volume and to examine the relation of plasma fentanyl concentration and temperature to Bispectral Index (BIS) as an index of conscious level during infant cardiac surgery. Prospective cohort study. Tertiary care, academic children's hospital. Fifteen neonates and infants undergoing cardiac surgery with hypothermic cardiopulmonary bypass (CPB). Patients were anesthetized with fentanyl, receiving a 30 microg/kg bolus for induction immediately followed by continuous infusion of 0.3 microg/kg/min until skin closure. Intraoperative data and total plasma fentanyl concentration were measured at preinduction; 30 minutes postinduction; sternotomy; aortic cannulation; at 4, 30, and 60 minutes on CPB; and at 1 and 30 minutes off CPB. At the onset of CPB, fentanyl declined from 15 +/- 6 to 11 +/- 5 ng/mL (p < 0.01), increasing to 16 +/- 5 ng/mL (p < 0.01) at 30 minutes on CPB and maintaining a similar level until 30 minutes off CPB. BIS decreased from 88 +/- 20 to 42 +/- 11 (p = 0.02) with induction, declined further during cooling to 9 +/- 11 at the nadir temperature ( p < 0.001), and increased during rewarming to 29 +/- 9 at 1 minute (p < 0.001) and 35 +/- 10 at 30 minutes off CPB ( p < 0.01). Because of wide individual variation in BIS, there was no significant correlation between fentanyl and BIS and temperature. There was minimal variability in the plasma fentanyl concentration using a low-volume bypass circuit and constant infusion of fentanyl during surgery. There appears to be minimal utility for using BIS during infant cardiac surgery with no relationship between fentanyl concentration, temperature, and BIS established.
James, R J; Irons, D W; Holmes, C; Charlton, A L; Drewett, R F; Baylis, P H
1995-09-01
There have been anecdotal reports of increased maternal thirst during breast feeding, but the physiological mechanisms remain obscure. We have assessed and quantified the stimulation of maternal thirst during breast feeding (suckling), and correlated the changes with plasma oxytocin and vasopressin levels. A within subject design was used with each subject acting as her own control. Each subject participated in a suckling period and a control non-suckling period the order of which was counterbalanced. Ten healthy breastfeeding women ranging from 28 to 52 days post partum. Thirst (assessed by a visual analogue scale), plasma vasopressin, plasma oxytocin (pOT), plasma osmolality and haematocrit, blood pressure, volume of milk transferred to baby, volume of water drunk immediately following each experimental period. Thirst increased significantly more over a suckling period than over a comparable control period (P = 0.013). The peak level of thirst correlated with the volume of water consumed to satiety following the suckling period (r = 0.7, P = 0.024). As expected, pOT levels rose significantly in response to suckling (P < 0.001). Six women demonstrated a close relation between thirst and oxytocin response during the suckling period. Despite significant changes in thirst during suckling there was no increase in plasma vasopressin or in osmoregulatory parameters. This study confirms that suckling is a potent stimulus to thirst in the mother, and is not associated with vasopressin release or dependent on any measurable alterations in osmoregulation. What actually stimulates thirst during breast feeding remains unknown, but there are two potential explanations for these observations: (1) suckling sends nerve impulses to the paraventricular and supraoptic nuclei in the hypothalamus which may have afferents within the central nervous system which stimulates a thirst response simultaneous with oxytocin release; (ii) a learned anticipation of thirst may be occurring in a situation associated with expectant fluid loss to preserve homeostasis.
A scalable, micropore, platelet rich plasma separation device.
Dickson, Mary Nora; Amar, Levy; Hill, Michael; Schwartz, Joseph; Leonard, Edward F
2012-12-01
We have designed a novel, low energy platelet-rich-plasma (PRP) separator capable of producing 50 mL of PRP in 30 min, intended for military and emergency applications. Blood flows over a 3 mm length of sieve at high rates of shear. A plasma-platelet filtrate passes through the sieve's pores while erythrocytes remain. The filtrate is flowed over a second 3 mm length of smaller-pored sieve that withdraws plasma. Bulk blood volume is maintained by returning platelet-free plasma to the erythrocyte pool, enabling a nearly complete multi-pass platelet extraction. The total percentage of platelets extracted is:θ(T)=1-exp (-V(f)(T)Φ(P)/V) where V is the original plasma volume, V ( f )(T) is the total filtered volume, and ϕ ( P ) is platelet passage ratio (filtrate concentration/bulk average concentration) taken to be constant. Maximum θ(T) occurs at maximum V ( f )(T)× ϕ ( P ) Test microsieves, 3 mm long × 3 mm wide, were used. ϕ ( P ) values measured at various filtrate flow rates (20-100 uL/min) and utilizing various filter pore sizes (1.2-3.5 μm), was as high as 150 %. Maximum V ( f )(T)× ϕ ( P ) was achieved utilizing the 3.5 um filters at the highest flow rate, 100 uL/min. Erythrocyte leakages were always below 2,000/uL, far below the allowable limit stipulated by the American Association of Blood Banking. These data imply that a 13.7 cm(2) filter area is sufficient to achieve the target separation of 50 mL of platelet concentrate in 30 min. The filtration cartridge would consist of multiple microporous strips of 3 mm width arranged in parallel so that each element would see the conditions used in the prototype experiments presented here. Other microfiltration schemes suggest no method of scaling to practical levels.
Passenger fluid volumes measured before and after a prolonged commercial jet flight.
NASA Technical Reports Server (NTRS)
Johnson, P. C.; Carpentier, W. R.; Driscoll, T. B.; Lapinta, C. K.; Rummel, J. A.; Sawin, C. F.
1972-01-01
Interstitial and intracellular fluid volumes were calculated from measured plasma volume, extracellular volume and total body water of six subjects before and after a 24-hour commercial overseas flight. No change occurred in these spaces or in peripheral hematocrit or total serum protein concentration. The subjective feeling of dehydration and the actual swelling of the lower extremities characteristically found among passengers at the end of a long trip of this type seems to represent a shift in body fluids to the dependent portions of the body rather than water retention or a decrease in the intravascular water volume.
Electrostatic plasma lens for focusing negatively charged particle beams.
Goncharov, A A; Dobrovolskiy, A M; Dunets, S M; Litovko, I V; Gushenets, V I; Oks, E M
2012-02-01
We describe the current status of ongoing research and development of the electrostatic plasma lens for focusing and manipulating intense negatively charged particle beams, electrons, and negative ions. The physical principle of this kind of plasma lens is based on magnetic isolation electrons providing creation of a dynamical positive space charge cloud in shortly restricted volume propagating beam. Here, the new results of experimental investigations and computer simulations of wide-aperture, intense electron beam focusing by plasma lens with positive space charge cloud produced due to the cylindrical anode layer accelerator creating a positive ion stream towards an axis system is presented.
The effect of thiopental sodium, methoxyflurane and halothane on the acid-base status in sheep.
Edjtehadi, M; Howard, B R
1978-01-01
Experiments have been carried out on 20 adult fat-tailed ewes to determine the effects of thiopental sodium, methoxyflurane and halothane on acid-base status of the saliva loss during prolonged surgical anaesthesia. The rate of loss of base in saliva depends on the volume of saliva produced, which fell sharply at the onset of anesthesia with the volatile anaesthesia. Plasma pH and plasma pvCO2 excess were both increased by the volatile anaesthetics but fell sharply during thiopental anaesthesia. Plasma pH and plasma PvCO2 showed no consistent relationship. PMID:688076
NASA Astrophysics Data System (ADS)
Baksht, E. Kh; Lomaev, Mikhail I.; Rybka, D. V.; Tarasenko, Viktor F.
2006-06-01
The emission properties of a volume nanosecond discharge plasma produced in xenon, krypton and argon at high pressures in a discharge gap with a cathode having a small radius of curvature are studied. Spectra in the range 120-850 nm and amplitude—time characteristics of xenon emission at different regimes and excitation techniques are recorded and analysed. It is shown that upon excitation of the volume discharge initiated by a beam of avalanche electrons, at least 90% of the energy in the spectral range 120-850 nm is emitted by xenon dimers. For xenon at a pressure of 1.2 atm, ~45 mJ of the spontaneous emission energy was obtained in the full solid angle in a pulse with the full width at half-maximum ~130 ns.
Himber, J; Bühler, E; Moll, D; Moser, U K
1995-01-01
A rapid method is described for the isolation of small volumes of plasma low density lipoprotein (LDL) free of plasma protein contaminants using the TL-100 Tabletop Ultracentrifuge (Beckman). The isolation of LDL was achieved by a 25 min discontinuous gradient density centrifugation between the density range of 1.006 and 1.21 g/ml, recovery of LDL by tube slicing followed by a 90 min flotation step (d = 1.12 g/ml). The purity of LDL and apolipoprotein B100 (apo B100) were monitored by agarose electrophoresis, sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE), radial immunodiffusion and micropreparative fast protein liquid chromatography (FPLC). The ability of LDL oxidation was assessed by following absorbance at 234 nm after addition of copper ions. The functional integrity of the isolated LDL was checked by clearance kinetics after injection of [125I]-labelled LDL in estrogen-treated rats. The additional purification step led to LDL fractions free of protein contamination and left apo B100, alpha-tocopherol and beta-carotene intact. The LDL prepared in this way was free of albumin, as evident from analytic tests and from its enhanced oxidative modification by copper ions. Used for analytical purposes, this method allows LDL preparations from plasma volumes up to 570 microliters. This method is also convenient for metabolic studies in small animals, especially those relating to the determination of kinetic parameters of LDL in which LDL-apo B100 has to be specifically radiolabelled.
Increased renal tubular sodium reabsorption during exercise-induced hypervolemia in humans
NASA Technical Reports Server (NTRS)
Nagashima, K.; Wu, J.; Kavouras, S. A.; Mack, G. W.
2001-01-01
We tested the hypothesis that renal tubular Na(+) reabsorption increased during the first 24 h of exercise-induced plasma volume expansion. Renal function was assessed 1 day after no-exercise control (C) or intermittent cycle ergometer exercise (Ex, 85% of peak O(2) uptake) for 2 h before and 3 h after saline loading (12.5 ml/kg over 30 min) in seven subjects. Ex reduced renal blood flow (p-aminohippurate clearance) compared with C (0.83 +/- 0.12 vs. 1.49 +/- 0.24 l/min, P < 0.05) but did not influence glomerular filtration rates (97 +/- 10 ml/min, inulin clearance). Fractional tubular reabsorption of Na(+) in the proximal tubules was higher in Ex than in C (P < 0.05). Saline loading decreased fractional tubular reabsorption of Na(+) from 99.1 +/- 0.1 to 98.7 +/- 0.1% (P < 0.05) in C but not in Ex (99.3 +/- 0.1 to 99.4 +/- 0.1%). Saline loading reduced plasma renin activity and plasma arginine vasopressin levels in C and Ex, although the magnitude of decrease was greater in C (P < 0.05). These results indicate that, during the acute phase of exercise-induced plasma volume expansion, increased tubular Na(+) reabsorption is directed primarily to the proximal tubules and is associated with a decrease in renal blood flow. In addition, saline infusion caused a smaller reduction in fluid-regulating hormones in Ex. The attenuated volume-regulatory response acts to preserve distal tubular Na(+) reabsorption during saline infusion 24 h after exercise.
Equations of state and diagrams of two-dimensional liquid dusty plasmas
NASA Astrophysics Data System (ADS)
Feng, Yan; Lin, Wei; Li, Wei; Wang, Qiaoling
2016-09-01
Recently, the pressure of two-dimensional (2D) Yukawa liquids has been calculated from the simulations of isochores [Feng et al., J. Phys. D: Appl. Phys. 49, 235203 (2016)], which is applicable to 2D dusty plasmas. Thus, the equation of state for 2D strongly coupled liquid dusty plasmas is obtained. Isobars and isotherms of 2D liquid dusty plasmas are derived from this equation of state. For 2D liquid dusty plasmas, the surface corresponding to this equation of state has also been obtained in the 3D space of the pressure, the temperature, and the screening parameter which is related to the volume in the equilibrium state.
Apparatus and method for carbon fiber surface treatment
Paulauskas, Felix L; Sherman, Daniel M
2014-06-03
An apparatus and method for enhancing the surface energy and/or surface chemistry of carbon fibers involves exposing the fibers to direct or indirect contact with atmospheric pressure plasma generated using a background gas containing at least some oxygen or other reactive species. The fiber may be exposed directly to the plasma, provided that the plasma is nonfilamentary, or the fiber may be exposed indirectly through contact with gases exhausting from a plasma discharge maintained in a separate volume. In either case, the process is carried out at or near atmospheric pressure, thereby eliminating the need for vacuum equipment. The process may be further modified by moistening the fibers with selected oxygen-containing liquids before exposure to the plasma.
Apparatus and method for carbon fiber surface treatment
Paulauskas, Felix L [Knoxville, TN; Sherman, Daniel M [Knoxville, TN
2012-07-24
An apparatus and method for enhancing the surface energy and/or surface chemistry of carbon fibers involves exposing the fibers to direct or indirect contact with atmospheric pressure plasma generated using a background gas containing at least some oxygen or other reactive species. The fiber may be exposed directly to the plasma, provided that the plasma is nonfilamentary, or the fiber may be exposed indirectly through contact with gases exhausting from a plasma discharge maintained in a separate volume. In either case, the process is carried out at or near atmospheric pressure, thereby eliminating the need for vacuum equipment. The process may be further modified by moistening the fibers with selected oxygen-containing liquids before exposure to the plasma.
Physicochemical mechanisms of plasma-liquid interactions within plasma channels in liquid
NASA Astrophysics Data System (ADS)
Franclemont, Joshua; Fan, Xiangru; Mededovic Thagard, Selma
2015-10-01
The goal of this study is to advance the fundamental understanding of the physical and chemical mechanisms by which excited radical species produced by electrical plasmas directly in water, OH radicals especially, induce chemical changes in aqueous organic compounds and to exploit this for the development and optimization of drinking and wastewater plasma-based treatment systems. To achieve this goal, this study measured and correlated the production rate of hydrogen peroxide (H2O2) with physicochemical properties of 11 organic compounds. The observed individual correlations between the investigated physicochemical properties and the resulting H2O2 concentrations were used to develop an equation that would allow predicting the measured H2O2 concentration from physicochemical properties of a compound. Results reveal that the production rate of H2O2 directly depends on the surface tension of the solution and compounds’ bulk liquid concentration, hydrophobicity (K ow value), and molecular volume. Other properties such as vapor pressure, Henry’s constant, enthalpy of vaporization, ionization energy, electron affinity, and molecular dipole moment do not affect the H2O2 chemistry. K ow value and surface tension of the solution determine the compound’s concentration at the plasma interface. Once at the interface, the molecular volume determines the rate at which the molecule will react with OH radicals.
Bohnert, Sara; Vair, Cory; Mikler, John
2010-05-15
A rapid and small volume assay to quantify HI-6 in plasma was developed to further the development and licensing of an intravenous formulation of HI-6. The objective of this method was to develop a sensitive and rapid assay that clearly resolved HI-6 and an internal standard in saline and plasma matrices. A fully validated method using ion-pair HPLC and 2-PAM as the internal standard fulfilled these requirements. Small plasma samples of 35 microL were extracted using acidification, filtration and neutralization. Linearity was shown for over 4 microg/mL to 1mg/mL with accuracy and precision within 6% relative error at the lower limit of detection. This method was utilized in the pharmacokinetic analysis HI-6 dichloride (2Cl) and HI-6 dimethane sulfonate (DMS) in anaesthetized guinea pigs and domestic swine following an intravenous bolus administration. From the resultant pharmacokinetic parameters a target plasma concentration of 100 microM was established and maintained in guinea pigs receiving an intravenous infusion. This validated method allows for the analysis of low volume samples, increased sample numbers and is applicable to the determination of pharmacokinetic profiles and parameters. Copyright (c) 2010. Published by Elsevier B.V.
Bédard, Sophie; Sicotte, Benoit; St-Louis, Jean; Brochu, Michèle
2005-02-01
We previously reported that sodium restriction during pregnancy reduces plasma volume expansion and promotes intra-uterine growth restriction (IUGR) in rats while it activates the renin-angiotensin-aldosterone system (RAAS). In the present study, we proceeded to determine whether expression of the two angiotensin II (ANGII) receptor subtypes (AT(1) and AT(2)) change in relation to maternal water-electrolyte homeostasis and fetal growth. To this end, pregnant (gestation day 15) and non-pregnant Sprague-Dawley rats were randomly assigned to two groups fed either normal, or Na(+)-restricted diets for 7 days. At the end of the treatment period, plasma aldosterone and renin activity as well as plasma and urine electrolytes were measured. Determinations for AT(1) and AT(2) mRNA and protein were made by RNase protection assay and photoaffinity labelling, respectively, using a number of tissues implicated in volume regulation and fetal growth. In non-pregnant rats, Na(+) restriction decreases Na(+) excretion without altering plasma volume, plasma Na(+) concentration or the expression of AT(1) and AT(2) mRNA or protein in the tissues examined. In normally fed pregnant rats when compared to non-pregnant controls, AT(1) mRNA increases in the hypothalamus as well as pituitary and declines in uterine arteries, while AT(1) protein decreases in the kidney and AT(2) mRNA declines in the adrenal cortex. In pregnant rats, Na(+) restriction induces a decrease in plasma Na(+), an increase in plasma urea, as well as a decline in renal urea and creatinine clearance rates. Protein levels for both AT(1) and AT(2) in the pituitary and AT(2) mRNA in the adrenal cortex are lower in the Na(+)-restricted pregnant group when compared to normally fed pregnant animals. Na(+) restriction also induces a decrease in AT(1) protein in the placenta. In conclusion, these results suggest that pregnancy may increase sensitivity to Na(+) depletion by the tissue-specific modulation of ANGII receptors. Finally, these receptors may be implicated in the IUGR response to low Na(+).
Hall Current Plasma Source Having a Center-Mounted or a Surface-Mounted Cathode
NASA Technical Reports Server (NTRS)
Martinez, Rafael A. (Inventor); Moritz, Jr., Joel A. (Inventor); Williams, John D. (Inventor); Farnell, Casey C. (Inventor)
2018-01-01
A miniature Hall current plasma source apparatus having magnetic shielding of the walls from ionized plasma, an integrated discharge channel and gas distributor, an instant-start hollow cathode mounted to the plasma source, and an externally mounted keeper, is described. The apparatus offers advantages over other Hall current plasma sources having similar power levels, including: lower mass, longer lifetime, lower part count including fewer power supplies, and the ability to be continuously adjustable to lower average power levels using pulsed operation and adjustment of the pulse duty cycle. The Hall current plasma source can provide propulsion for small spacecraft that either do not have sufficient power to accommodate a propulsion system or do not have available volume to incorporate the larger propulsion systems currently available. The present low-power Hall current plasma source can be used to provide energetic ions to assist the deposition of thin films in plasma processing applications.
Physics through the 1990s: Plasmas and fluids
NASA Technical Reports Server (NTRS)
1986-01-01
The volume contains recommendations for programs in, and government support of, plasma and fluid physics. Four broad areas are covered: the physics of fluids, general plasma physics, fusion, and space and astrophysical plasmas. In the first section, the accomplishments of fluid physics and a detailed review of its sub-fields, such as combustion, non-Newtonian fluids, turbulence, aerodynamics, and geophysical fluid dynamics, are described. The general plasma physics section deals with the wide scope of the theoretical concepts involved in plasma research, and with the machines; intense beam systems, collective and laser-driven accelerators, and the associated diagnostics. The section on the fusion plasma research program examines confinement and heating systems, such as Tokamaks, magnetic mirrors, and inertial-confinement systems, and several others. Finally, theory and experiment in space and astrophysical plasma research is detailed, ranging from the laboratory to the solar system and beyond. A glossary is included.
NASA Astrophysics Data System (ADS)
Watanabe, Takayuki; Kaneko, Toshio; Sekine, Makoto; Tanaka, Yasunori
2013-06-01
The 11th Asia-Pacific Conference on Plasma Science and Technology (APCPST-11) was held in Kyoto, Japan on 2-5 October 2012 with the 25th Symposium on Plasma Science for Materials (SPSM-25). SPSM has been held annually since 1988 under the sponsorship of The 153rd Committee on Plasma Materials Science, Japan Society for the Promotion of Science (JSPS). This symposium is one of the major activities of the Committee, which is organized by researchers in academia and industry for the purpose of advancing intersectional scientific information exchange and discussion of science and technology of plasma materials processing. APCPST and SPSM are jointly held biennially to survey the current status of low temperature and thermal plasma physics and chemistry for industrial applications. The whole area of plasma processing was covered from fundamentals to applications. Previous meetings were held in China, Japan, Korea, and Australia, attended by scientists from the Asia-Pacific and other countries. The joint conference was organized in plenary lectures, invited, contributed oral presentations and poster sessions. At this meeting, we had 386 participants from 10 countries and 398 presentations, including 26 invited presentations. This year, we arranged special topical sessions that covered green innovation, life innovation, and technical reports from industry. This conference seeks to bring the plasma community together and to create a forum for discussing the latest developments and issues, the challenges ahead in the field of plasma research and applications among engineers and scientists in Asia, the Pacific Rim, as well as Europe. This volume presents 44 papers that were selected via a strict peer-review process from full papers submitted for the proceedings of the conference. The topics range from the basic physics and chemistry of plasma processing to a broad variety of materials processing and environmental applications. This volume offers an overview of recent advances in thermal and non-equilibrium plasmas as well as on more new and innovative developments in the field of life innovation, green innovation and a technical report session. The editors hope that this volume will be useful and helpful for deepening our understanding of science and technology of plasma materials processing and also for stimulating further development of the plasma technology. Finally, we would like to thank the conference chairmen, the members of the organizing committee, the advisory committee, the executive committee, the program committee, the publication committee, organizing secretariat and financial support from The 153rd Committee on Plasma Materials Science, JSPS. Sponsors and Supporting Organization: The 153rd Committee on Plasma Materials Science, Japan Society for the Promotion of Science Organizing Committee Chairperson: Osamu Tsuji, SAMCO Corporation, Japan Advisory Committee Chairperson: Akihisa Matsuda, Osaka University, Japan Executive Committee Chairperson: Masaru Hori, Nagoya University, Japan Program Committee Chairperson: Takamasa Ishigaki, Hosei University, Japan Publication Committee Chairperson: Takayuki Watanabe, Kyushu University Editors of APCPST-11 and SPMS-25 Professor Takayuki Watanabe, Kyushu University, Japan Professor Toshio Kaneko, Tohoku University, Japan Professor Makoto Sekine, Nagoya University, Japan Professor Yasunori Tanaka, Kanazawa University, Japan
Endocrine concomitants of sweating and sweat depression.
Candas, V; Brandenberger, G; Lutz-Bucher, B; Follenius, M; Libert, J P
1984-01-01
The effect of humid heat (Ta = 43 degrees C, Pa = 32 Torr) on sweat rate, plasma renin activity and plasma levels of aldosterone and antidiuretic hormone (ADH) was studied in four male subjects before and after repeated heat exposures. Over-sweating and sweat drippage followed by hidromeiosis were observed in three subjects during initial heat exposure. With repeated humid heat exposures increased sweat rates were accompanied by a more intense sweat depression (hidromeiosis) in all four subjects. In our conditions, no changes in plasma levels of aldosterone and ADH or plasma renin activity were observed with hidromeiosis. Plasma renin activity was slightly depressed by repeated exposures, whereas plasma volumes were enhanced, with no significant changes in plasma Na or K. The results suggest that neither ADH nor the components of the renin-angiotensin aldosterone system are involved in the hidromeiotic phenomenon.
Performance of the BATMAN RF source with a large racetrack shaped driver
NASA Astrophysics Data System (ADS)
Kraus, W.; Schiesko, L.; Wimmer, C.; Fantz, U.; Heinemann, B.
2017-08-01
In the negative ion sources in neutral beam injection systems (NBI) of future fusion reactors the plasma is generated in up to eight cylindrical RF sources ("drivers") from which it expands into the main volume. For these large sources, in particular those used in the future DEMO NBI, a high RF efficiency and operational reliability is required. To achieve this it could be favorable to substitute each pair of drivers by one larger one. To investigate this option the cylindrical driver of the BATMAN source at IPP Garching has been replaced by a large source with a racetrack shaped base area and tested using the same extraction system. The main differences are a five times larger source volume and another position of the Cs oven which is mounted onto the driver`s back plate and not onto the expansion volume. The conditioning characteristics and the plasma symmetry in front of the plasma grid were very similar. The extracted H- current densities jex are comparable to that achieved with the small driver at the same power. Because no saturation of jex occurred at 0.6 Pa at high power and the source allows high power operation, a maximum value 45.1 mA/cm2 at 103 kW has been reached. Sputtered Cu from the walls of the expansion volume affected the performance at low pressure, particularly in deuterium. The experiments will be therefore continued with Mo coating of all inner walls.
NASA Technical Reports Server (NTRS)
Baisch, F.; Beck, L.; Blomqvist, G.; Wolfram, G.; Drescher, J.; Rome, J. L.; Drummer, C.
2000-01-01
BACKGROUND: It is well known that space travel cause post-flight orthostatic hypotension and it was assumed that autonomic cardiovascular control deteriorates in space. Lower body negative pressure (LBNP) was used to assess autonomic function of the cardiovascular system. METHODS: LBNP tests were performed on six crew-members before and on the first days post-flight in a series of three space missions. Additionally, two of the subjects performed LBNP tests in-flight. LBNP mimics fluid distribution of upright posture in a gravity independent way. It causes an artificial sequestration of blood, reduces preload, and filtrates plasma into the lower part of the body. Fluid distribution was assessed by bioelectrical impedance and anthropometric measurements. RESULTS: Heart rate, blood pressure, and total peripheral resistance increased significantly during LBNP experiments in-flight. The decrease in stroke volume, the increased pooling of blood, and the increased filtration of plasma into the lower limbs during LBNP indicated that a plasma volume reduction and a deficit of the interstitial volume of lower limbs rather than a change in cardiovascular control was responsible for the in-flight response. Post-flight LBNP showed no signs of cardiovascular deterioration. The still more pronounced haemodynamic changes during LBNP reflected the expected behaviour of cardiovascular control faced with less intravascular volume. In-flight, the status of an intra-and extravascular fluid deficit increases sympathetic activity, the release of vasoactive substances and consequently blood pressure. Post-flight, blood pressure decreases significantly below pre-flight values after restoration of volume deficits. CONCLUSION: We conclude that the cardiovascular changes in-flight are a consequence of a fluid deficit rather than a consequence of changes in autonomic signal processing.
Human Physiology in an Aquatic Environment.
Pendergast, David R; Moon, Richard E; Krasney, John J; Held, Heather E; Zamparo, Paola
2015-09-20
Water covers over 70% of the earth, has varying depths and temperatures and contains much of the earth's resources. Head-out water immersion (HOWI) or submersion at various depths (diving) in water of thermoneutral (TN) temperature elicits profound cardiorespiratory, endocrine, and renal responses. The translocation of blood into the thorax and elevation of plasma volume by autotransfusion of fluid from cells to the vascular compartment lead to increased cardiac stroke volume and output and there is a hyperperfusion of some tissues. Pulmonary artery and capillary hydrostatic pressures increase causing a decline in vital capacity with the potential for pulmonary edema. Atrial stretch and increased arterial pressure cause reflex autonomic responses which result in endocrine changes that return plasma volume and arterial pressure to preimmersion levels. Plasma volume is regulated via a reflex diuresis and natriuresis. Hydrostatic pressure also leads to elastic loading of the chest, increasing work of breathing, energy cost, and thus blood flow to respiratory muscles. Decreases in water temperature in HOWI do not affect the cardiac output compared to TN; however, they influence heart rate and the distribution of muscle and fat blood flow. The reduced muscle blood flow results in a reduced maximal oxygen consumption. The properties of water determine the mechanical load and the physiological responses during exercise in water (e.g. swimming and water based activities). Increased hydrostatic pressure caused by submersion does not affect stroke volume; however, progressive bradycardia decreases cardiac output. During submersion, compressed gas must be breathed which introduces the potential for oxygen toxicity, narcosis due to nitrogen, and tissue and vascular gas bubbles during decompression and after may cause pain in joints and the nervous system. Copyright © 2015 John Wiley & Sons, Inc.
Exercise Thermoregulation in Men after One and 24-hours of 6 Degree Head-Down Tilt
NASA Technical Reports Server (NTRS)
Ertl, A. C.; Dearborn, A. S.; Weldhofer, A. R.; Bernauer, E. M.; Greenleaf, J. E.
1998-01-01
Exercise thermoregulation exercise is dependent on heat loss by increased skin blood flow (convective and conductive heat loss) and through enhanced sweating (evaporative heat loss). Reduction of plasma volume (PV), increased plasma osmolality, physical deconditioning, and duration of exposure to simulated and actual microgravity reduces the ability to thermoregulate during exercise.
Finite-volume scheme for anisotropic diffusion
DOE Office of Scientific and Technical Information (OSTI.GOV)
Es, Bram van, E-mail: bramiozo@gmail.com; FOM Institute DIFFER, Dutch Institute for Fundamental Energy Research, The Netherlands"1; Koren, Barry
In this paper, we apply a special finite-volume scheme, limited to smooth temperature distributions and Cartesian grids, to test the importance of connectivity of the finite volumes. The area of application is nuclear fusion plasma with field line aligned temperature gradients and extreme anisotropy. We apply the scheme to the anisotropic heat-conduction equation, and compare its results with those of existing finite-volume schemes for anisotropic diffusion. Also, we introduce a general model adaptation of the steady diffusion equation for extremely anisotropic diffusion problems with closed field lines.
Fluid and electrolyte shifts in women during +Gz acceleration after 15 days' bed rest
NASA Technical Reports Server (NTRS)
Greenleaf, J. E.; Stinnett, H. O.; Davis, G. L.; Kollias, J.; Bernauer, E. M.
1977-01-01
Experiments were conducted on twelve women aged 23-34 yr - a bed rest (BR) group of eight subjects and an ambulatory (AMB) group of four subjects - to determine the effect of bed rest on shifts in plasma volume, electrolytes, and erythrocyte volume during +Gz acceleration on a centrifuge. The BR group underwent the +Gz acceleration during a two-week ambulatory control period, after 15 days of a 17-day BR period, and on the third day of ambulatory recovery. The AMB group underwent the same experimental procedures, but continued their normal daily routine during the BR period without additional prescribed physical exercise. Major conclusions are that (1) the higher the mean control tolerance, the greater the tolerance decline after BR; (2) relative confinement and reduced activity contribute as much to reduction in tolerance as does the horizontal body position during BR; (3) BR deconditioning has no effect on the erythrocyte volume during +3.0 Gz; and (4) about one-half the loss in tolerance after BR can be attributed to plasma volume and electrolyte shifts.
Determining blood and plasma volumes using bioelectrical response spectroscopy
NASA Technical Reports Server (NTRS)
Siconolfi, S. F.; Nusynowitz, M. L.; Suire, S. S.; Moore, A. D. Jr; Leig, J.
1996-01-01
We hypothesized that an electric field (inductance) produced by charged blood components passing through the many branches of arteries and veins could assess total blood volume (TBV) or plasma volume (PV). Individual (N = 29) electrical circuits (inductors, two resistors, and a capacitor) were determined from bioelectrical response spectroscopy (BERS) using a Hewlett Packard 4284A Precision LCR Meter. Inductance, capacitance, and resistance from the circuits of 19 subjects modeled TBV (sum of PV and computed red cell volume) and PV (based on 125I-albumin). Each model (N = 10, cross validation group) had good validity based on 1) mean differences (-2.3 to 1.5%) between the methods that were not significant and less than the propagated errors (+/- 5.2% for TBV and PV), 2) high correlations (r > 0.92) with low SEE (< 7.7%) between dilution and BERS assessments, and 3) Bland-Altman pairwise comparisons that indicated "clinical equivalency" between the methods. Given the limitation of this study (10 validity subjects), we concluded that BERS models accurately assessed TBV and PV. Further evaluations of the models' validities are needed before they are used in clinical or research settings.
Whole body immersion and hydromineral homeostasis: effect of water temperature.
Jimenez, Chantal; Regnard, Jacques; Robinet, Claude; Mourot, Laurent; Gomez-Merino, Danielle; Chennaoui, Mounir; Jammes, Yves; Dumoulin, Gilles; Desruelle, Anne-Virginie; Melin, Bruno
2010-01-01
This experiment was designed to assess the effects of prolonged whole body immersion (WBI) in thermoneutral and cold conditions on plasma volume and hydromineral homeostasis.10 navy "combat swimmers" performed three static 6-h immersions at 34 degrees C (T34), 18 degrees C (T18) and 10 degrees C (T10). Rectal temperature, plasma volume (PV) changes, plasma proteins, plasma and urine ions, plasma osmolality, renin, aldosterone and antidiuretic hormone (ADH) were measured. Results show that compared to pre-immersion levels, PV decreased throughout WBI sessions, the changes being markedly accentuated in cold conditions. At the end of WBI, maximal PV variations were -6.9% at T34, -14.3% at T18, and -16.3% at T10. Plasma osmolality did not change during and after T34 immersion, while hyperosmolality was present at the end of T18 immersion and began after only 1 h of T10 immersion. In the three temperature conditions, significant losses of water (1.6-1.7 l) and salt (6-8 g) occurred and were associated with similar increases in osmolar and free water clearances. Furthermore, T18 and T10 immersions increased the glomerular filtration rate. There was little or no change in plasma renin and ADH, while the plasma level of aldosterone decreased equally in the three temperature conditions. In conclusion, our data indicate that cold water hastened PV changes induced by immersion, and increased the glomerular filtration rate, causing larger accumulated water losses. The iso-osmotic hypovolemia may impede the resumption of baseline fluid balance. Results are very similar to those repeatedly described by various authors during head-out water immersion.
Effect of dietary sodium on fluid/electrolyte regulation during bed rest
NASA Technical Reports Server (NTRS)
Williams, W. Jon; Schneider, Suzanne M.; Gretebeck, Randall J.; Lane, Helen W.; Stuart, Charles A.; Whitson, Peggy A.
2003-01-01
BACKGROUND: A negative fluid balance during bed rest (BR) is accompanied by decreased plasma volume (PV) which contributes to cardiovascular deconditioning. HYPOTHESIS: We hypothesized that increasing dietary sodium while controlling fluid intake would increase plasma osmolality (POSM), stimulate fluid conserving hormones, and reduce fluid/electrolyte (F/E) losses during BR; conversely, decreasing dietary sodium would decrease POSM, suppress fluid conserving hormones, and increase F/E losses. METHODS: We controlled fluid intake (30 ml x kg(-1) x d(-1)) in 17 men who consumed either a 4.0 +/- 0.06 g x d(-1) (174 mmol x d(-1)) (CONT; n = 6), 1.0 +/- 0.02 g x d(-1) (43 mmol x d(-1)) (LS; n = 6), or 10.0 +/- 0.04 g x d(-1) (430 mmol x d(-1)) (HS; n = 5) sodium diet before, during, and after 21 d of 6 degrees head-down BR. PV, total body water, urine volume and osmolality, POSM, and F/E controlling hormone concentrations were measured. RESULTS: In HS subjects, plasma renin activity (-92%), plasma/urinary aldosterone (-59%; -64%), and PV (-15.0%; 6.0 ml x kg(-1); p < 0.05) decreased while plasma atrial natriuretic peptide (+34%) and urine antidiuretic hormone (+24%) increased during BR (p < 0.05) compared with CONT. In LS, plasma renin activity (+166%), plasma aldosterone (+167%), plasma antidiuretic hormone (+19%), and urinary aldosterone (+335%) increased with no change in PV compared with CONT (p < 0.05). Total body water did not change in any of the subjects. CONCLUSIONS: Contrary to our hypothesis, increasing dietary sodium while controlling fluid intake during BR resulted in a greater loss of PV compared with the CONT subjects. Reducing dietary sodium while controlling fluid intake did not alter the PV response during BR compared with CONT subjects.
Hypovolemia in syncope and orthostatic intolerance role of the renin-angiotensin system
NASA Technical Reports Server (NTRS)
Jacob, G.; Robertson, D.; Mosqueda-Garcia, R.; Ertl, A. C.; Robertson, R. M.; Biaggioni, I.
1997-01-01
PURPOSE: Orthostatic intolerance is the cause of significant disability in otherwise normal patients. Orthostatic tachycardia is usually the dominant hemodynamic abnormality, but symptoms may include dizziness, visual changes, discomfort in the head or neck, poor concentration, fatigue, palpitations, tremulousness, anxiety and, in some cases, syncope. It is the most common disorder of blood pressure regulation after essential hypertension. There is a predilection for younger rather than older adults and for women more than men. Its cause is unknown; partial sympathetic denervation or hypovolemia has been proposed. METHODS AND MATERIALS: We tested the hypothesis that reduced plasma renin activity, perhaps from defects in sympathetic innervation of the kidney, could underlie a hypovolemia, giving rise to these clinical symptoms. Sixteen patients (14 female, 2 male) ranging in age from 16 to 44 years were studied. Patients were enrolled in the study if they had orthostatic intolerance, together with a raised upright plasma norepinephrine (> or = 600 pg/mL). Patients underwent a battery of autonomic tests and biochemical determinations. RESULTS: There was a strong positive correlation between the blood volume and plasma renin activity (r = 0.84, P = 0.001). The tachycardic response to upright posture correlated with the severity of the hypovolemia. There was also a correlation between the plasma renin activity measured in these patients and their concomitant plasma aldosterone level. CONCLUSIONS: Hypovolemia occurs commonly in orthostatic intolerance. It is accompanied by an inappropriately low level of plasma renin activity. The degree of abnormality of blood volume correlates closely with the degree of abnormality in plasma renin activity. Taken together, these observations suggest that reduced plasma renin activity may be an important pathophysiologic component of the syndrome of orthostatic intolerance.
New detection system and signal processing for the tokamak ISTTOK heavy ion beam diagnostic.
Henriques, R B; Nedzelskiy, I S; Malaquias, A; Fernandes, H
2012-10-01
The tokamak ISTTOK havy ion beam diagnostic (HIBD) operates with a multiple cell array detector (MCAD) that allows for the plasma density and the plasma density fluctuations measurements simultaneously at different sampling volumes across the plasma. To improve the capability of the plasma density fluctuations investigations, a new detection system and new signal conditioning amplifier have been designed and tested. The improvements in MCAD design are presented which allow for nearly complete suppression of the spurious plasma background signal by applying a biasing potential onto special electrodes incorporated into MCAD. The new low cost and small size transimpedance amplifiers are described with the parameters of 400 kHz, 10(7) V/A, 0.4 nA of RMS noise, adequate for the plasma density fluctuations measurements.
NASA Astrophysics Data System (ADS)
Kudryavtsev, A. A.; Serditov, K. Yu.
2012-07-01
This study presents 2D simulations of the two-chamber inductively coupled plasma source where power is supplied in the small discharge chamber and extends by electron thermal conductivity mechanism to the big diffusion chamber. Depending on pressure, two main scenarios of plasma density and its spatial distribution behavior were identified. One case is characterized by the localization of plasma in the small driver chamber where power is deposed. Another case describes when the diffusion chamber becomes the main source of plasma with maximum of the electron density. The differences in spatial distribution are caused by local or non-local behavior of electron energy transport in the discharge volume due to different characteristic scale of heat transfer with electronic conductivity.
Cotton, Bryan A; Podbielski, Jeanette; Camp, Elizabeth; Welch, Timothy; del Junco, Deborah; Bai, Yu; Hobbs, Rhonda; Scroggins, Jamie; Hartwell, Beth; Kozar, Rosemary A; Wade, Charles E; Holcomb, John B
2013-10-01
To determine whether resuscitation of severely injured patients with modified whole blood (mWB) resulted in fewer overall transfusions compared with component (COMP) therapy. For decades, whole blood (WB) was the primary product for resuscitating patients in hemorrhagic shock. After dramatic advances in blood banking in the 1970s, blood donor centers began supplying hospitals with individual components [red blood cell (RBC), plasma, platelets] and removed WB as an available product. However, no studies of efficacy or hemostatic potential in trauma patients were performed before doing so. Single-center, randomized trial of severely injured patients predicted to large transfusion volume. Pregnant patients, prisoners, those younger than 18 years or with more than 20% total body surface area burns (TBSA) burns were excluded. Patients were randomized to mWB (1 U mWB) or COMP therapy (1 U RBC+ 1 U plasma) immediately on arrival. Each group also received 1 U platelets (apheresis or prepooled random donor) for every 6 U of mWB or 6 U of RBC + 6 U plasma. The study was performed under the Exception From Informed Consent (Food and Drug Administration 21 code of federal regulations [CFR] 50.24). Primary outcome was 24-hour transfusion volumes. A total of 107 patients were randomized (55 mWB, 52 COMP therapy) over 14 months. There were no differences in demographics, arrival vitals or laboratory values, injury severity, or mechanism. Transfusions were similar between groups (intent-to-treat analysis). However, when excluding patients with severe brain injury (sensitivity analysis), WB group received less 24-hour RBC (median 3 vs 6, P = 0.02), plasma (4 vs 6, P = 0.02), platelets (0 vs 3, P = 0.09), and total products (11 vs 16, P = 0.02). Compared with COMP therapy, WB did not reduce transfusion volumes in severely injured patients predicted to receive massive transfusion. However, in the sensitivity analysis (patients without severe brain injuries), use of mWB significantly reduced transfusion volumes, achieving the prespecified endpoint of this initial pilot study.
NASA'S Standard Measures During Bed Rest: Adaptations in the Cardiovascular System
NASA Technical Reports Server (NTRS)
Lee, Stuart M. C.; Feiveson, Alan H.; Martin, David S.; Cromwell, Roni L.; Platts, Steven H.; Stenger, Michael B.
2016-01-01
Bed rest is a well-accepted analog of space flight that has been used extensively to investigate physiological adaptations in a larger number of subjects in a shorter amount of time than can be studied with space flight and without the confounding effects associated with normal mission operations. However, comparison across studies of different bed rest durations, between sexes, and between various countermeasure protocols have been hampered by dissimilarities in bed rest conditions, measurement protocols, and testing schedules. To address these concerns, NASA instituted standard bed rest conditions and standard measures for all physiological disciplines participating in studies conducted at the Flight Analogs Research Unit (FARU) at the University of Texas-Medical Branch. Investigators for individual studies employed their own targeted study protocols to address specific hypothesis-driven questions, but standard measures tests were conducted within these studies on a non-interference basis to maximize data availability while reducing the need to implement multiple bed rest studies to understand the effects of a specific countermeasure. When possible, bed rest standard measures protocols were similar to tests nominally used for medically-required measures or research protocols conducted before and after Space Shuttle and International Space Station missions. Specifically, bed rest standard measures for the cardiovascular system implemented before, during, and after bed rest at the FARU included plasma volume (carbon monoxide rebreathing), cardiac mass and function (2D, 3D and Doppler echocardiography), and orthostatic tolerance testing (15- or 30-minutes of 80 degree head-up tilt). Results to-date indicate that when countermeasures are not employed, plasma volume decreases and the incidence of presyncope during head-up tilt is more frequent even after short-duration bed rest while reductions in cardiac function and mass are progressive as bed rest duration increases. Additionally, while plasma volume loss can be corrected and cardiac mass can be prevented with properly applied countermeasures, orthostatic tolerance is more difficult to protect when supine exercise is the only countermeasure. Similar results have been observed after space flight. Plasma volume, cardiac chamber volume, and orthostatic tolerance recover relatively quickly with resumption of ambulation and normal activity levels after bed rest but restoration of cardiac mass is prolonged.
Tantalum Etching with an Atmospheric Pressure Plasma Jet
NASA Astrophysics Data System (ADS)
Teslow, Hilary; Herrmann, Hans; Rosocha, Louis
2002-10-01
The APPJ is a non-thermal, atmospheric-pressure, glow discharge. A feedgas, composed of an inert carrier gas (e.g., He) and small concentrations of additives (e.g., O2, or CF4), flows between closely spaced electrodes powered at 13.56 MHz rf in a coaxial or parallel plate arrangement. The plasma has Te ˜ 2 eV and ne ˜ 10^11 cm-3. Electrons are not in thermal equilibrium with ions and neutrals: the electrons are ``hot", while the overall gas temperature is quite ``cold", typically 50-300 C. In the plasma, the gas is excited, dissociated or ionized by energetic electron impact. As the gas exits the discharge volume, ions and electrons are rapidly lost by recombination, leaving metastables (e.g. O2*, He*) and radicals (e.g. O, F, OF, O2F, CFO). These reactive species are then directed onto a surface to be processed. The APPJ has been developed for decontaminating nuclear, chemical, and biological agents. Atomic fluorine, and possibly other reactive species, can be used to convert actinides (e.g., U and Pu), into volatile fluorides (e.g., UF6, PuF6) that can be trapped, resulting in significant volume reduction of radioactive waste. In this talk, we will present results on using Ta as a surrogate for Pu in He/O2/CF4 etching plasmas. Results of experimental measurements of Ta etch rates for various gas mixtures and plasma jet standoff distance will be compared with plasma chemistry modeling of the concentrations of several active species produced in the plasma.
Mechanisms responsible for decreased glomerular filtration in hibernation and hypothermia
NASA Technical Reports Server (NTRS)
Tempel, G. E.; Musacchia, X. J.; Jones, S. B.
1977-01-01
Measurements of blood pressure, heart rate, red blood cell and plasma volumes, and relative distribution of cardiac output were made on hibernating and hypothermic adult male and female golden hamsters weighing 120-140 g to study the mechanisms underlying the elimination or marked depression of renal function in hibernation and hypothermia. The results suggest that the elimination or marked depression in renal function reported in hibernation and hypothermia may partly be explained by alterations in cardiovascular system function. Renal perfusion pressure which decreases nearly 60% in both hibernation and hypothermia and a decrease in plasma volume of roughly 35% in the hypothermic animal might both be expected to markedly alter glomerular function.
1991-12-01
results were to be generated in a form suitable for use in the Physiologically Based Pharmacokinetic Models. The literature was searched from 1979 to...body Blood flow % Cardiac 02 consumption wt(kg) weight (ml/min) output (ml/min/organ) Brain 1.4 2.0 775 15 46 Heart 0.3 0.43 175 3.3 23 Kidneys 0.3 0.43...Plasma Flow 500-800 ml/min(calculated per 24 hours) Volume, Blood 49-75m1\\kg body wt.Male 56-75m1/kg body wt.Female 2 500-400m1 /m2 Plasma 31-55m1/kg
Plasma Structure and Behavior of Miniature Ring-Cusp Discharges
NASA Astrophysics Data System (ADS)
Mao, Hann-Shin
Miniature ring-cusp ion thrusters provide a unique blend of high efficiencies and millinewton level thrust for future spacecraft. These thrusters are attractive as a primary propulsion for small satellites that require a high delta V, and as a secondary propulsion for larger spacecraft that require precision formation flying, disturbance rejection, or attitude control. To ensure desirable performance throughout the life of such missions, an advancement in the understanding of the plasma structure and behavior of miniature ring-cusp discharges is required. A research model was fabricated to provide a simplified experimental test bed for the analysis of the plasma discharge chamber of a miniature ion thruster. The plasma source allowed for spatially resolved measurements with a Langmuir probe along a meridian plane. Probe measurements yielded plasma density, electron temperature, and plasma potential data. The magnetic field strength was varied along with the discharge current to determine the plasma behavior under various conditions. The structure of the plasma properties were found to be independent of the discharge power under the proper scaling. It was concluded that weaker magnetic fields can improve the overall performance for ion thruster operation. To further analyze the experimental measurements, a framework was developed based on the magnetic field. A flux aligned coordinate system was developed to decouple the perpendicular and parallel plasma motion with respect to the magnetic field. This was done using the stream function and magnetic scalar potential. Magnetic formulae provided intuition on the field profiles dependence on magnet dimensions. The flux aligned coordinate system showed that the plasma was isopycnic along constant stream function values. This was used to develop an empirical relation suitable for estimating the spatial behavior and to determine the plasma volume and loss areas. The plasma geometry estimates were applied to a control volume analysis on the plasma electrons. Balancing the plasma electron generation and loss yielded nominal values used in miniature ion thrusters. This result was ultimately used to develop a design tool for miniature discharges. This tool was used to perform a parametric evaluation on the magnet field configuration of the research mode. By understanding the plasma behavior, significant improvements over the baseline configuration were obtained with relatively minor changes, thus revealing the importance of plasma structure on the performance of miniature ring-cusp discharges.
Mondal, Mohan; Baruah, Kishore Kumar; Prakash, B S
2016-01-01
Mithun (Bos frontalis) is a semi-wild rare ruminant species. A simple sensitive enzymeimmunoassay suitable for assaying FSH in the blood plasma of mithun is not available which thereby limits our ability to understand this species reproductive processes. Therefore, the aim of this article was to develop a simple and sensitive enzymeimmunoassay (EIA) for estimation of FSH in mithun plasma and apply the assay to understand the estrous cycle and superovulatory process in this species. To accomplish this goal, biotinylated FSH was bridged between streptavidin-peroxidase and immobilized antiserum in a competitive assay. Forty microlitre mithun plasma was used directly in the EIA. The FSH standards were prepared in hormone free plasma and ranged from 5-1280 pg/well/40 μL. The sensitivity of EIA was 5 pg/well FSH, which corresponds to 0.125 ng/mL plasma and the 50% relative binding sensitivity was 90 pg/well/40 μL. Although the shape of the standard curve was not influenced by different plasma volumes viz. 40 and 80 μL, a slight drop in the OD450 was observed with the increasing volume of plasma. Parallelism tests conducted between the endogenous mithun FSH and bovine FSH standards showed good homology between them. Plasma FSH estimated using the developed EIA and commercially available FSH EIA kit in the same samples were correlated (r = 0.98) and showed linearity. Both the Intra- and inter-assay CV were below 6%. Recovery of known concentrations of added FSH showed linearity (r = 0.99). The developed EIA was further validated biologically by estimating FSH in cyclic cows for the entire estrous cycle, in mithun heifers administered with GnRH analogues and in mithun cows during superovulatory treatment with FSH. In conclusion, the EIA developed for FSH determination in mithun blood plasma is simple and highly sensitive for estimation of mithun FSH in all physiological conditions.
Simple, miniaturized blood plasma extraction method.
Kim, Jin-Hee; Woenker, Timothy; Adamec, Jiri; Regnier, Fred E
2013-12-03
A rapid plasma extraction technology that collects a 2.5 μL aliquot of plasma within three minutes from a finger-stick derived drop of blood was evaluated. The utility of the plasma extraction cards used was that a paper collection disc bearing plasma was produced that could be air-dried in fifteen minutes and placed in a mailing envelop for transport to an analytical laboratory. This circumvents the need for venipuncture and blood collection in specialized vials by a phlebotomist along with centrifugation and refrigerated storage. Plasma extraction was achieved by applying a blood drop to a membrane stack through which plasma was drawn by capillary action. During the course of plasma migration to a collection disc at the bottom of the membrane stack blood cells were removed by a combination of adsorption and filtration. After the collection disc filled with an aliquot of plasma the upper membranes were stripped from the collection card and the collection disc was air-dried. Intercard differences in the volume of plasma collected varied approximately 1% while volume variations of less than 2% were seen with hematocrit levels ranging from 20% to 71%. Dried samples bearing metabolites and proteins were then extracted from the disc and analyzed. 25-Hydroxy vitamin D was quantified by LC-MS/MS analysis following derivatization with a secosteroid signal enhancing tag that imparted a permanent positive charge to the vitamin and reduced the limit of quantification (LOQ) to 1 pg of collected vitamin on the disc; comparable to values observed with liquid-liquid extraction (LLE) of a venipuncture sample. A similar study using conventional proteomics methods and spectral counting for quantification was conducted with yeast enolase added to serum as an internal standard. The LOQ with extracted serum samples for enolase was 1 μM, linear from 1 to 40 μM, the highest concentration examined. In all respects protein quantification with extracted serum samples was comparable to that observed with serum samples obtained by venipuncture.
Adeosun, Olukayode Isaac; Olaniyi, Kehinde S; Amusa, Oluwatobi A; Jimoh, Gbemisola Z; Oniyide, Adesola A
2017-01-01
Cola nitida (Kolanut) is conventionally used in tropical Africa for the treatment of all kinds of ailments such as migraine, morning sickness, metabolic disorders etc. However, this study was designed to investigate the diuretic, natriuretic and kaliuretic activities of methanolic extract of Cola nitida (MECN) in male Wistar rats. Adult male Wistar rats were randomly allotted into control (25 ml/kg b.w .), furosemide (20 mg/kg b.w ; standard), MECN 1 (100 mg/kg), MECN 2 (200 mg/kg), MECN 3 (300 mg/kg), MECN 4 (400 mg/kg), MECN 5 (500 mg/kg), MECN 6 (600 mg/kg) groups with n=6. The extract was prepared as previously described and the treatment lasted for 14 days. Urine volume and diuretic indices were estimated. Urine electrolytes, plasma electrolytes, plasma/renal AST/ALT, plasma creatinine and urea were assayed using flame photometry and standard colorimetric method respectively.Administration of different doses of C. nitida significantly altered body weight gain and water intake but not food intake compared with control group. There were significant increases in urine volume and urine electrolytes (Na + , K + and Cl - ), a decrease in plasma/renal ALT and AST activities, a decrease in plasma creatinine and urea concentration and no alteration in plasma electrolytes when compared with control and furosemide-treated groups. Our study suggests that MECN elicits diuretic, natriuretic, and kaliuretic activities without causing electrolyte impairment, hepatotoxicity and nephrotoxicity. These effects are dose-dependent.
Adeosun, Olukayode Isaac; Olaniyi, Kehinde S; Amusa, Oluwatobi A; Jimoh, Gbemisola Z; Oniyide, Adesola A
2017-01-01
Cola nitida (Kolanut) is conventionally used in tropical Africa for the treatment of all kinds of ailments such as migraine, morning sickness, metabolic disorders etc. However, this study was designed to investigate the diuretic, natriuretic and kaliuretic activities of methanolic extract of Cola nitida (MECN) in male Wistar rats. Adult male Wistar rats were randomly allotted into control (25 ml/kg b.w.), furosemide (20 mg/kg b.w; standard), MECN1 (100 mg/kg), MECN2 (200 mg/kg), MECN3 (300 mg/kg), MECN4 (400 mg/kg), MECN5 (500 mg/kg), MECN6 (600 mg/kg) groups with n=6. The extract was prepared as previously described and the treatment lasted for 14 days. Urine volume and diuretic indices were estimated. Urine electrolytes, plasma electrolytes, plasma/renal AST/ALT, plasma creatinine and urea were assayed using flame photometry and standard colorimetric method respectively.Administration of different doses of C. nitida significantly altered body weight gain and water intake but not food intake compared with control group. There were significant increases in urine volume and urine electrolytes (Na+, K+ and Cl-), a decrease in plasma/renal ALT and AST activities, a decrease in plasma creatinine and urea concentration and no alteration in plasma electrolytes when compared with control and furosemide-treated groups. Our study suggests that MECN elicits diuretic, natriuretic, and kaliuretic activities without causing electrolyte impairment, hepatotoxicity and nephrotoxicity. These effects are dose-dependent. PMID:29348800
Design, simulation and construction of the Taban tokamak
NASA Astrophysics Data System (ADS)
H, R. MIRZAEI; R, AMROLLAHI
2018-04-01
This paper describes the design and construction of the Taban tokamak, which is located in Amirkabir University of Technology, Tehran, Iran. The Taban tokamak was designed for plasma investigation. The design, simulation and construction of essential parts of the Taban tokamak such as the toroidal field (TF) system, ohmic heating (OH) system and equilibrium field system and their power supplies are presented. For the Taban tokamak, the toroidal magnetic coil was designed to produce a maximum field of 0.7 T at R = 0.45 m. The power supply of the TF was a 130 kJ, 0–10 kV capacitor bank. Ripples of toroidal magnetic field at the plasma edge and plasma center are 0.2% and 0.014%, respectively. For the OH system with 3 kA current, the stray field in the plasma region is less than 40 G over 80% of the plasma volume. The power supply of the OH system consists of two stages, as follows. The fast bank stage is a 120 μF, 0–5 kV capacitor that produces 2.5 kA in 400 μs and the slow bank stage is 93 mF, 600 V that can produce a maximum of 3 kA. The equilibrium system can produce uniform magnetic field at plasma volume. This system’s power supply, like the OH system, consists of two stages, so that the fast bank stage is 500 μF, 800 V and the slow bank stage is 110 mF, 200 V.
Changes in plasma volume and baroreflex function following resistance exercise
NASA Technical Reports Server (NTRS)
Ploutz, L. L.; Tatro, D. L.; Dudley, G. A.; Convertino, V. A.
1993-01-01
The dynamics of change in plasma volume (PV) and baroreflex responses have been reported over 24 h immediately following maximal cycle exercise. The purpose of this study was to determine if PV and baroreflex showed similar changes for 24 h after resistance exercise. Eight men were studied on 2 test days, 1 week apart. On 1 day, per cent change (% delta) in PV was estimated at 0,3, and 6 h after resistance exercise using haematocrit and haemoglobin. Baseline PV was measured 24 h after exercise using Evans blue dye. The carotid baroreceptor-cardiac reflex response was measured before, and 3, 6, 9, 12, and 24 h post-exercise. Each subject performed six sets of the bench press and leg press with 10 repetitions per set with a load that induced failure within each set. On a control day, the protocol was used without exercise. Plasma volume did not change during the control day. There was a 20% decrease in PV immediately post-exercise; the recovery of the PV was rapid and complete within 3 h. PV was 20% greater 24 h post-exercise than on the control day. There were no differences in any of the baroreflex measurements. Therefore, it is suggested that PV shifts may occur without altering baroreflex sensitivity.
A collimated neutron detector for RFP plasmas in MST
DOE Office of Scientific and Technical Information (OSTI.GOV)
Capecchi, W. J., E-mail: capecchi@wisc.edu; Anderson, J. K.; Bonofiglo, P. J.
The neutron emissivity profile in the Madison Symmetric Torus is being reconstructed through the use of a collimated neutron detector. A scintillator-photomultiplier tube (PMT) system is employed to detect the fusion neutrons with the plasma viewing volume defined by a 55 cm deep, 5 cm diameter aperture. Effective detection of neutrons from the viewing volume is achieved through neutron moderation using 1300 lbs of high density polyethylene shielding, which modeling predicts attenuates the penetrating flux by a factor of 10{sup 4} or more. A broad spectrum of gamma radiation is also present due to the unconfined fusion proton bombardment ofmore » the thick aluminum vacuum vessel. A 15 cm cylindrical liquid scintillator of 3.8 cm diameter is used to further increase directional sensitivity. A fast (5 ns rise time) preamplifier and digitization at 500 MHz prevent pulse pile-up even at high count rates (∼10{sup 4}/s). The entire neutron camera system is situated on an adjustable inclining base which provides the differing plasma viewing volumes necessary for reconstruction of the neutron emissivity profile. This profile, directly related to the fast-ion population, allows for an investigation of the critical fast-ion pressure gradient required to destabilize a neutral beam driven Alfvénic mode which has been shown to transport fast ions.« less
NASA Technical Reports Server (NTRS)
Wright, K. H., Jr.; Stone, N. H.; Samir, U.
1983-01-01
In this review attention is called to basic phenomena and physical processes involved in the expansion of a plasma into a vacuum, or the expansion of a plasma into a more tenuous plasma, in particular the fact that upon the expansion, ions are accelerated and reach energies well above their thermal energy. Also, in the process of the expansion a rarefaction wave propagates into the ambient plasma, an ion front moves into the expansion volume, and discontinuities in plasma parameters occur. The physical processes which cause the above phenomena are discussed, and their possible application is suggested for the case of the distribution of ions and electrons (hence plasma potential and electric fields) in the wake region behind artificial and natural obstacles moving supersonically in a rarefied space plasma. To illustrate this, some in situ results are reexamined. Directions for future work in this area via the utilization of the Space Shuttle and laboratory work are also mentioned.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kourtzanidis, Konstantinos, E-mail: kkourt@utexas.edu; Pederson, Dylan M.; Raja, Laxminarayan L.
2016-05-28
We propose and study numerically a tunable and reconfigurable metamaterial based on coupled split-ring resonators (SRRs) and plasma discharges. The metamaterial couples the magnetic-electric response of the SRR structure with the electric response of a controllable plasma slab discharge that occupies a volume of the metamaterial. Because the electric response of a plasma depends on its constitutive parameters (electron density and collision frequency), the plasma-based metamaterial is tunable and active. Using three-dimensional numerical simulations, we analyze the coupled plasma-SRR metamaterial in terms of transmittance, performing parametric studies on the effects of electron density, collisional frequency, and the position of themore » plasma slab with respect to the SRR array. We find that the resonance frequency can be controlled by the plasma position or the plasma-to-collision frequency ratio, while transmittance is highly dependent on the latter.« less
PREFACE: 12th High-Tech Plasma Processes Conference (HTPP-12)
NASA Astrophysics Data System (ADS)
Gleizes, Alain; Ghedini, Emanuele; Gherardi, Matteo; Sanibondi, Paolo; Dilecce, Giorgio
2012-12-01
The High-Tech Plasma Processes - 12th European Plasma Conference (HTPP-12) was held in Bologna (Italy) on 24-29 June 2012. The conference series started in 1990 as a thermal plasma conference and gradually expanded to include other topic fields as well. Now the High-Tech Plasma Processes - European Plasma Conference (HTPP) is a bi-annual international conference based in Europe with topics encompassing the whole area of plasma processing science. The aim of the conference is to bring different scientific communities together, facilitate the contacts between science, technology and industry and provide a platform for the exploration of both fundamental topics and new applications of plasmas. Thanks to the efforts of the conference chairman, Professor Vittorio Colombo and of the co-chair, Professor Piero Favia, a well balanced participation from both the communities of thermal and nonthermal plasma researchers was achieved; this resulted in just about 196 attendees from 39 countries, with 8 plenary and 15 invited talks, plus 50 oral and 140 poster contributions. This volume of Journal of Physics: Conference Series gathers papers from regular contributions of HTPP-12; each contribution submitted for publication has been peer reviewed and the Editors are very grateful to the referees for their careful support in improving the original manuscripts. In the end, 39 manuscripts were accepted for publication, covering different topics of plasma processing science: from plasma fundamentals and modelling to source design and process diagnostics, from nanomaterial synthesis to surface modification, from waste treatment to plasma applications in a liquid environment. It is an honour to present this volume of Journal of Physics: Conference Series and we deeply thank the authors for their enthusiastic and high-grade contribution. Finally, we would like to thank the conference chairmen, the members of the steering committee, the international scientific committee, the local organizing committee, the organizing secretariat and the financial support from the conference sponsors that allowed the success of HTPP-12. The Editors of the HTPP 12 Proceedings Professor Alain Gleizes (head of the ISC) Dr Emanuele Ghedini Dr Matteo Gherardi Dr Paolo Sanibondi Dr Giorgio Dilecce Bologna, 30 October 2012
Compact Plasma Accelerator for Micropropulsion Applications
NASA Technical Reports Server (NTRS)
Foster, John E.
2001-01-01
There is a need for a low power, light-weight (compact), high specific impulse electric propulsion device to satisfy mission requirements for microsatellite (1 to 20 kg) class missions. Satisfying these requirements entails addressing the general problem of generating a sufficiently dense plasma within a relatively small volume and then accelerating it. In the work presented here, the feasibility of utilizing a magnetic cusp to generate a dense plasma over small length scales of order 1 mm is investigated. This approach could potentially mitigate scaling issues associated with conventional ion thruster plasma containment schemes. Plume and discharge characteristics were documented using a Faraday probe and a retarding potential analyzer.
Rapid recipe formulation for plasma etching of new materials
NASA Astrophysics Data System (ADS)
Chopra, Meghali; Zhang, Zizhuo; Ekerdt, John; Bonnecaze, Roger T.
2016-03-01
A fast and inexpensive scheme for etch rate prediction using flexible continuum models and Bayesian statistics is demonstrated. Bulk etch rates of MgO are predicted using a steady-state model with volume-averaged plasma parameters and classical Langmuir surface kinetics. Plasma particle and surface kinetics are modeled within a global plasma framework using single component Metropolis Hastings methods and limited data. The accuracy of these predictions is evaluated with synthetic and experimental etch rate data for magnesium oxide in an ICP-RIE system. This approach is compared and superior to factorial models generated from JMP, a software package frequently employed for recipe creation and optimization.
Hull, D.E.
1982-07-02
An induction plasma tube having a segmented, fluid-cooled internal radiation shield is disclosed. The individual segments are thick in cross-section such that the shield occupies a substantial fraction of the internal volume of the plasma enclosure, resulting in improved performance and higher sustainable plasma temperatures. The individual segments of the shield are preferably cooled by means of a counterflow fluid cooling system wherein each segment includes a central bore and a fluid supply tube extending into the bore. The counterflow cooling system results in improved cooling of the individual segments and also permits use of relatively larger shield segments which permit improved electromagnetic coupling between the induction coil and a plasma located inside the shield. Four embodiments of the invention, each having particular advantages, are disclosed.
Hull, Donald E.
1984-01-01
An induction plasma tube having a segmented, fluid-cooled internal radiation shield is disclosed. The individual segments are thick in cross-section such that the shield occupies a substantial fraction of the internal volume of the plasma enclosure, resulting in improved performance and higher sustainable plasma temperatures. The individual segments of the shield are preferably cooled by means of a counterflow fluid cooling system wherein each segment includes a central bore and a fluid supply tube extending into the bore. The counterflow cooling system results in improved cooling of the individual segments and also permits use of relatively larger shield segments which permit improved electromagnetic coupling between the induction coil and a plasma located inside the shield. Four embodiments of the invention, each having particular advantages, are disclosed.
Study of Inactivation Factors in Low Temperature Surface-wave Plasma Sterilization
NASA Astrophysics Data System (ADS)
Singh, Mrityunjai Kumar; Xu, Lei; Ogino, Akihisa; Nagatsu, Masaaki
In this study we investigated the low temperature surface-wave plasma sterilization of directly and indirectly exposed Geobacillus stearothermophilus spores with a large-volume microwave plasma device. The air-simulated gas mixture was used to produce the plasma. The water vapor addition to the gas mixture improved the sterilization efficiency significantly. The effect of ultraviolet photons produced along with plasma to inactivate the spores was studied using a separate chamber, which was evacuated to less than one mTorr and was observed that spores were sterilized within 60 min. The scanning electron microscopy images revealed no significant changes in the actual size of the spores with that of untreated spores despite the survival curve shown that the spores were inactivated.
Investigation on Plasma Jet Flow Phenomena During DC Air Arc Motion in Bridge-Type Contacts
NASA Astrophysics Data System (ADS)
Zhai, Guofu; Bo, Kai; Chen, Mo; Zhou, Xue; Qiao, Xinlei
2016-05-01
Arc plasma jet flow in the air was investigated under a bridge-type contacts in a DC 270 V resistive circuit. We characterized the arc plasma jet flow appearance at different currents by using high-speed photography, and two polished contacts were used to search for the relationship between roughness and plasma jet flow. Then, to make the nature of arc plasma jet flow phenomena clear, a simplified model based on magnetohydrodynamic (MHD) theory was established and calculated. The simulated DC arc plasma was presented with the temperature distribution and the current density distribution. Furthermore, the calculated arc flow velocity field showed that the circular vortex was an embodiment of the arc plasma jet flow progress. The combined action of volume force and contact surface was the main reason of the arc jet flow. supported by National Natural Science Foundation of China (Nos. 51307030, 51277038)
High-Gain High-Field Fusion Plasma
Li, Ge
2015-01-01
A Faraday wheel (FW)—an electric generator of constant electrical polarity that produces huge currents—could be implemented in an existing tokamak to study high-gain high-field (HGHF) fusion plasma, such as the Experimental Advanced Superconducting Tokamak (EAST). HGHF plasma can be realized in EAST by updating its pulsed-power system to compress plasma in two steps by induction fields; high gains of the Lawson trinity parameter and fusion power are both predicted by formulating the HGHF plasma. Both gain rates are faster than the decrease rate of the plasma volume. The formulation is checked by earlier ATC tests. Good agreement between theory and tests indicates that scaling to over 10 T at EAST may be possible by two-step compressions with a compression ratio of the minor radius of up to 3. These results point to a quick new path of fusion plasma study, i.e., simulating the Sun by EAST. PMID:26507314
Extreme plasma states in laser-governed vacuum breakdown.
Efimenko, Evgeny S; Bashinov, Aleksei V; Bastrakov, Sergei I; Gonoskov, Arkady A; Muraviev, Alexander A; Meyerov, Iosif B; Kim, Arkady V; Sergeev, Alexander M
2018-02-05
Triggering vacuum breakdown at laser facility is expected to provide rapid electron-positron pair production for studies in laboratory astrophysics and fundamental physics. However, the density of the produced plasma may cease to increase at a relativistic critical density, when the plasma becomes opaque. Here, we identify the opportunity of breaking this limit using optimal beam configuration of petawatt-class lasers. Tightly focused laser fields allow generating plasma in a small focal volume much less than λ 3 and creating extreme plasma states in terms of density and produced currents. These states can be regarded to be a new object of nonlinear plasma physics. Using 3D QED-PIC simulations we demonstrate a possibility of reaching densities over 10 25 cm -3 , which is an order of magnitude higher than expected earlier. Controlling the process via initial target parameters provides an opportunity to reach the discovered plasma states at the upcoming laser facilities.
Fully Implict Magneto-hydrodynamics Simulations of Coaxial Plasma Accelerators
Subramaniam, Vivek; Raja, Laxminarayan L.
2017-01-05
The resistive Magneto-Hydrodynamic (MHD) model describes the behavior of a strongly ionized plasma in the presence of external electric and magnetic fields. We developed a fully implicit MHD simulation tool to solve the resistive MHD governing equations in the context of a cell-centered finite-volume scheme. The primary objective of this study is to use the fully-implicit algorithm to obtain insights into the plasma acceleration and jet formation processes in Coaxial Plasma accelerators; electromagnetic acceleration devices that utilize self-induced magnetic fields to accelerate thermal plasmas to large velocities. We also carry out plasma-surface simulations in order to study the impact interactionsmore » when these high velocity plasma jets impinge on target material surfaces. Scaling studies are carried out to establish some basic functional relationships between the target-stagnation conditions and the current discharged between the coaxial electrodes.« less
Production of dense plasmas in a hypocycloidal pinch apparatus
NASA Technical Reports Server (NTRS)
Lee, J. H.; Mcfarland, D. R.; Hohl, F.
1977-01-01
A high-power pinch apparatus consisting of disk electrodes was developed, and diagnostic measurements to study its mechanism of dense plasma production have been made. The collapse fronts of the current sheets are well organized, and dense plasma foci are produced on the axis with radial stability in excess of 5 microsec. A plasma density greater than 10 to the 18th power per cu cm is determined with Stark broadening and CO2 laser absorption. Essentially complete absorption of a high-energy CO2 laser beam has been observed. A plasma temperature of approximately 1 keV is measured with differential transmission of soft X-rays through thin foils. The advantages of this apparatus over the coaxial plasma focus are improvements in (1) plasma volume, (2) stability, (3) containment time, (4) access to additional heating by laser or electron beams, and (5) the possibility of scaling up to a multiple array for high-power operation.
Dense plasma focus production in a hypocycloidal pinch
NASA Technical Reports Server (NTRS)
Lee, J. H.; Mcfarland, D. R.; Hohl, F.
1975-01-01
A type of high-power pinch apparatus consisting of disk electrodes was developed, and diagnostic measurements to study its mechanism of dense plasma production were made. The collapse fronts of the current sheets are well organized, and dense plasma focuses are produced on the axis with radial stability in excess of 5 microns. A plasma density greater than 10 to the 18th power/cubic cm was determined with Stark broadening and CO2 laser absorption. A plasma temperature of approximately 1 keV was measured with differential transmission of soft X-rays through thin foils. Essentially complete absorption of a high-energy CO2 laser beam was observed. The advantages of this apparatus over the coaxial plasma focus are in (1) the plasma volume, (2) the stability, (3) the containment time, (4) the easy access to additional heating by laser or electron beams, and (5) the possibility of scaling up to a multiple array for high-power operation.
Medical Aspects of Harsh Environments. Volume 2
2002-01-01
Fulco CS, Trad LA, Forte VA, Cymerman A. Altitude acclimatization attenuates plasma ammonia accumulation during submaximal exercise. J Appl Physiol...107 and decreased ammonia accumulation66 and dependence on muscle glyco- gen.109 These hypoxia-produced changes in oxygen delivery and metabolic profile...Young PM, Rock PB, Fulco CS, Trad LA, Forte VA Jr, Cymerman A. Altitude acclimatization attenuates plasma ammonia accumulation during submaximal
Proceedings of Symposium on Energy Engineering in the 21st Century (SEE 2000). Volume One
2000-01-13
18, pp. 81-90 (1978). 9. G. Venuti and P. Valentin , High Temp. High Pressure, 11, pp. 301-310 (1979). 10. A.B. Murphy, Plasma Chemistry and Plasma...Galloway and Mudawar [7] for forced convection boiling in a narrow channel. (3) Based on the experiments by Tong et al. [8], and Carvalho and Bergles
ERIC Educational Resources Information Center
Scanlan, Aaron T.; Richter-Stretton, Gina L.; Madueno, Maria C.; Borges, Nattai R.; Fenning, Andrew S.
2017-01-01
Measurement of plasma osmolality (P[subscript osm]) remains popular for assessing hydration status in exercise science. However, a controlled reliability assessment of micro-osmometry using small sample volumes to measure Posm remains to be performed. This study aimed to examine the reliability of a cryoscopic micro-osmometer requiring 15-µL…
Ferrokinetics in Patients on CAPD: Influence of CAPD on the Anemia of Uremia*
Lee, Hi Bahl; Koh, Seong Won; Park, Hee Sook
1986-01-01
Ferrokinetic studies were performed with 59Fe-citrate to evaluate erythropoietic activity in CAPD patients and to investigate the mechanism(s) by which the hematocrit increases in CAPD patients. Plasma iron disappearance rate (PID), plasma iron turnover rate (PIT), red cell iron utilization (RCIU), red cell iron turnover rate (RCIT) and marrow transit time (MTT) were all “normal” in uremic patients not yet on dialysis (Hct 23.8±3.4%), CAPD patients with persistently low hematocrit (Hct 24.9±1.8%) and CAPD patients with improved hematocrit (Hct 32.4±3.1%). Compared to these uremic patients, patients with iron deficiency anemia and normal renal function (Hct 28.0±5.1 %) had significantly faster PID and MTT and significantly higher RCIU and RCIT. Plasma volume was significantly reduced (to normal level) in CAPD patients with improved hematocrits. The results of this study suggest that erythropoietic activity is inadequate for the degree of anemia in CAPD patients as well as uremic patients not on dialysis and further suggest that the hematocrit increases in CAPD as a result of decreased plasma volume. PMID:15759377
Elevated central venous pressure: a consequence of exercise training-induced hypervolemia?
NASA Technical Reports Server (NTRS)
Convertino, V. A.; Mack, G. W.; Nadel, E. R.
1991-01-01
Resting blood volumes and arterial and central venous pressures (CVP) were measured in 14 men before and after exercise training to determine whether training-induced hypervolemia is accompanied by a change in total vascular capacitance. In addition, resting levels of plasma arginine vasopressin (AVP), atrial natriuretic peptide (ANP), aldosterone (Ald), and norepinephrine (NE) were measured. The same measurements were conducted in seven subjects who did not undergo exercise and acted as controls. Exercise training consisted of 10 wk of controlled cycle exercise for 30 min/day, 4 days/wk at 75-80% of maximal O2 uptake (VO2max). A training effect was verified by a 20% increase in VO2max, a resting bradycardia, and a 9% increase in blood volume. Mean arterial blood pressure was unaltered by exercise training, but resting CVP increased by 16% (P less than 0.05). The percent change in blood volume from before to after training was linearly related to the percent change in CVP (r = 0.903, P less than 0.05). As a consequence of elevations in both blood volume and CVP, the volume-to-pressure ratio was unchanged after exercise training. Plasma AVP, ANP, Ald, and NE were unaltered. Our results indicate that elevated CVP is a consequence of training-induced hypervolemia without alteration in total effective venous capacitance.
3D Analysis of Porosity in a Ceramic Coating Using X-ray Microscopy
NASA Astrophysics Data System (ADS)
Klement, Uta; Ekberg, Johanna; Kelly, Stephen T.
2017-02-01
Suspension plasma spraying (SPS) is a new, innovative plasma spray technique using a feedstock consisting of fine powder particles suspended in a liquid. Using SPS, ceramic coatings with columnar microstructures have been produced which are used as topcoats in thermal barrier coatings. The microstructure contains a wide pore size range consisting of inter-columnar spacings, micro-pores and nano-pores. Hence, determination of total porosity and pore size distribution is a challenge. Here, x-ray microscopy (XRM) has been applied for describing the complex pore space of the coatings because of its capability to image the (local) porosity within the coating in 3D at a resolution down to 50 nm. The possibility to quantitatively segment the analyzed volume allows analysis of both open and closed porosity. For an yttria-stabilized zirconia coating with feathery microstructure, both open and closed porosity were determined and it could be revealed that 11% of the pore volumes (1.4% of the total volume) are closed pores. The analyzed volume was reconstructed to illustrate the distribution of open and closed pores in 3D. Moreover, pore widths and pore volumes were determined. The results on the complex pore space obtained by XRM are discussed in connection with other porosimetry techniques.
High-voltage electrode optimization towards uniform surface treatment by a pulsed volume discharge
NASA Astrophysics Data System (ADS)
Ponomarev, A. V.; Pedos, M. S.; Scherbinin, S. V.; Mamontov, Y. I.; Ponomarev, S. V.
2015-11-01
In this study, the shape and material of the high-voltage electrode of an atmospheric pressure plasma generation system were optimised. The research was performed with the goal of achieving maximum uniformity of plasma treatment of the surface of the low-voltage electrode with a diameter of 100 mm. In order to generate low-temperature plasma with the volume of roughly 1 cubic decimetre, a pulsed volume discharge was used initiated with a corona discharge. The uniformity of the plasma in the region of the low-voltage electrode was assessed using a system for measuring the distribution of discharge current density. The system's low-voltage electrode - collector - was a disc of 100 mm in diameter, the conducting surface of which was divided into 64 radially located segments of equal surface area. The current at each segment was registered by a high-speed measuring system controlled by an ARM™-based 32-bit microcontroller. To facilitate the interpretation of results obtained, a computer program was developed to visualise the results. The program provides a 3D image of the current density distribution on the surface of the low-voltage electrode. Based on the results obtained an optimum shape for a high-voltage electrode was determined. Uniformity of the distribution of discharge current density in relation to distance between electrodes was studied. It was proven that the level of non-uniformity of current density distribution depends on the size of the gap between electrodes. Experiments indicated that it is advantageous to use graphite felt VGN-6 (Russian abbreviation) as the material of the high-voltage electrode's emitting surface.
Liu, Rui; Hu, Xiao-Hang; Wang, Shu-Ming; Guo, Si-Jia; Li, Zong-Yu; Bai, Xiao-Dong; Zhou, Fang-Qiang; Hu, Sen
2016-06-01
To investigate whether pyruvate-enriched oral rehydration solution (Pyr-ORS), compared with citrate-enriched ORS (Cit-ORS), improves hemodynamics and organ function by alleviating vasopermeability and plasma volume loss during intra-gastric fluid rehydration in dogs with severe burn. Forty dogs subjected to severe burn were randomly divided into four groups (n=10): two oral rehydrated groups with Pyr-ORS and Cit-ORS (group PR and group CR), respectively, according to the Parkland formula during the first 24h after burns. Other two groups were the intravenous (IV) resuscitation (group VR) with lactated Ringer's solution with the same dosage and no fluid rehydration (group NR). During the next 24h, all groups received the same IV infusion. The hemodynamics, plasma volume, vasopermeability and water contents and function of various organs were determined. Plasma levels of vascular endothelial growth factor (VEGF) and platelet activating factor (PAF) were detected by ELISA. Hemodynamics parameters were significantly improved in group PR superior to group CR after burns. Levels of VEGF and PAF were significantly lower in group PR than in group CR. Organ function parameters were also greatly preserved in group PR, relative to groups CR and NR. Lactic acidosis was fully corrected and survival increased in group PR (50.0%), compared to group CR (20.0%). Pyr-ORS was more effective than Cit-ORS in improving hemodynamics, visceral blood perfusion and organ function by alleviating vasopermeability-induced visceral edema and plasma volume loss in dogs with severe burn. Copyright © 2016 Elsevier Ltd and ISBI. All rights reserved.
Collective Phenomena In Volume And Surface Barrier Discharges
NASA Astrophysics Data System (ADS)
Kogelschatz, U.
2010-07-01
Barrier discharges are increasingly used as a cost-effective means to produce non-equilibrium plasmas at atmospheric pressure. This way, copious amounts of electrons, ions, free radicals and excited species can be generated without appreciable gas heating. In most applications the barrier is made of dielectric material. In laboratory experiments also the use of resistive, ferroelectric and semiconducting materials has been investigated, also porous ceramic layers and dielectric barriers with controlled surface conductivity. Major applications utilizing mainly dielectric barriers include ozone generation, surface cleaning and modification, polymer and textile treatment, sterilization, pollution control, CO2 lasers, excimer lamps, plasma display panels (flat TV screens). More recent research efforts are also devoted to biomedical applications and to plasma actuators for flow control. Sinu- soidal feeding voltages at various frequencies as well as pulsed excitation schemes are used. Volume as well as surface barrier discharges can exist in the form of filamentary, regularly patterned or laterally homogeneous discharges. Reviews of the subject and the older literature on barrier discharges were published by Kogelschatz (2002, 2003), by Wagner et al. (2003) and by Fridman et al. (2005). A detailed discussion of various properties of barrier discharges can also be found in the recent book "Non-Equilibrium Air Plasmas at Atmospheric Pressure" by Becker et al. (2005). The physical effects leading to collective phenomena in volume and surface barrier discharges will be discussed in detail. Special attention will be given to self-organization of current filaments. Main similarities and differences of the two types of barrier discharges will be elaborated.
Howards, Stuart S.; Davis, Bernard B.; Knox, Franklyn G.; Wright, Fred S.; Berliner, Robert W.
1968-01-01
The effect of infusions of hyperoncotic solutions on fractional sodium reabsorption by the proximal tubule of the dog was studied by the recollection micropuncture method. Tubule fluid to plasma inulin concentration ratios were measured for identified proximal tubule segments before and after infusion of 25% albumin or dextran solutions. Results were compared with changes in fractional reabsorption during saline diuresis. Plasma volume increased 66% ± SE 5.8 after infusion of albumin solution and 94% ± SE 8.2 after infusion of dextran solution. Fractional sodium reabosorption by the proximal tubule was depressed after infusion of both of these hyperoncotic solutions. Nevertheless, changes in sodium excretion after infusion of albumin and dextran were small. In contrast, after infusions of isotonic sodium chloride solution, which increased plasma volume 61% ± SE 5.8, a decrease in fractional reabsorption of 50.7% ± SE 7.2 was associated with large changes in sodium excretion. PMID:5658588
Interplanetary medium data book, supplement 5, 1988-1993
NASA Technical Reports Server (NTRS)
King, Joseph H.; Papitashvili, Natalia E.
1994-01-01
This publication represents an extension of the series of Interplanetary Medium Data Books and supplements that have been issued by the National Space Science Data Center since 1977. This volume contains solar wind magnetic field and plasma data from the IMP 8 spacecraft for 1988 through the end of 1993. The normalization of the MIT plasma density and temperature, which has been discussed at length in previous volumes, is implemented as before, using the same normalization constants for 1988-1993 data as for the earlier data. Owing to a combination of non-continuity of IMP 8 telemetry acquisition and IMP's being out of the solar wind for about 40 percent of its orbit, the annual solar wind coverage for 1988-1993 is 40 plus or minus 5 percent. The plots and listings of this supplement are in essentially the same format as in previous supplements. Days for which neither IMF nor plasma data were available for any hours are omitted from the listings.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gao, Ruilin; Yuan, Chengxun, E-mail: yuancx@hit.edu.cn, E-mail: zhouzx@hit.edu.cn; Jia, Jieshu
The interaction between microwave and large area plasma is crucially important for space communication. Gas pressure, input power, and plasma volume are critical to both the microwave electromagnetic wave phase shift and electron density. This paper presents a novel type of large coaxial gridded hollow cathode plasma having a 50 cm diameter and a 40 cm thickness. Microwave characteristics are studied using a microwave measurement system that includes two broadband antennae in the range from 2 GHz to 18 GHz. The phase shift under varying gas pressure and input power is shown. In addition, the electron density n{sub e}, whichmore » varies from 1.2 × 10{sup 16} m{sup −3} to 8.7 × 10{sup 16} m{sup −3} under different discharge conditions, is diagnosed by the microwave system. The measured results accord well with those acquired by Langmuir Probe measurement and show that the microwave properties in the large volume hollow cathode discharge significantly depend on the input power and gas pressure.« less
Filters for cathodic arc plasmas
Anders, Andre; MacGill, Robert A.; Bilek, Marcela M. M.; Brown, Ian G.
2002-01-01
Cathodic arc plasmas are contaminated with macroparticles. A variety of magnetic plasma filters has been used with various success in removing the macroparticles from the plasma. An open-architecture, bent solenoid filter, with additional field coils at the filter entrance and exit, improves macroparticle filtering. In particular, a double-bent filter that is twisted out of plane forms a very compact and efficient filter. The coil turns further have a flat cross-section to promote macroparticle reflection out of the filter volume. An output conditioning system formed of an expander coil, a straightener coil, and a homogenizer, may be used with the magnetic filter for expanding the filtered plasma beam to cover a larger area of the target. A cathodic arc plasma deposition system using this filter can be used for the deposition of ultrathin amorphous hard carbon (a-C) films for the magnetic storage industry.
Ground-based plasma contractor characterization
NASA Technical Reports Server (NTRS)
Patterson, Michael J.; Aadland, Randall S.
1987-01-01
Presented are recent NASA Lewis Research Center (LeRC) plasma contractor experimental results, as well as a description of the plasma contractor test facility. The operation of a 24 cm diameter plasma source with hollow cathode was investigated in the lighted-mode regime of electron current collection from 0.1 to 7.0 A. These results are compared to those obtained with a 12 cm plasma source. Full two-dimensional plasma potential profiles were constructed from emissive probe traces of the contractor plume. The experimentally measured dimensions of the plume sheaths were then compared to those theoretically predicted using a model of a spherical double sheath. Results are consistent for currents up to approximately 1.0 A. For currents above 1.0 A, substantial deviations from theory occur. These deviations are due to sheath asphericity, and possibly volume ionization in the double-sheath region.
Effects of head-down tilt on fluid and electrolyte balance
NASA Technical Reports Server (NTRS)
Volicer, L.; Jean-Charles, R.; Chobanian, A. V.
1976-01-01
The metabolic effects of -5 deg tilt were studied in eight normal individuals. Exposure to tilt for 24 hr increased sodium excretion and decreased plasma volume. Plasma renin activity and plasma aldosterone levels were not significantly different from supine values during the first 6 hr of tilting, but were increased significantly at the end of the 24-hr tilt period. Creatinine clearance and potassium balance were not affected by the tilt. These findings indicate that head-down tilt induces a sodium diuresis and stimulation of the renin-angiotensin-aldosterone system.
Lynn, Alan G; Gilmore, Mark
2014-11-01
Magnetized Liner Inertial Fusion (MagLIF) experiments, where a metal liner is imploded to compress a magnetized seed plasma may generate peak magnetic fields ∼10(4) T (100 Megagauss) over small volumes (∼10(-10)m(3)) at high plasma densities (∼10(28)m(-3)) on 100 ns time scales. Such conditions are extremely challenging to diagnose. We discuss the possibility of, and issues involved in, using polarimetry techniques at x-ray wavelengths to measure magnetic fields under these extreme conditions.
Apparatus and method for electrical insulation in plasma discharge systems
Rhodes, Mark A [Redwood City, CA; Fochs, Scott N [Livermore, CA
2003-08-12
An apparatus and method to contain plasma at optimal fill capacity of a metallic container is disclosed. The invention includes the utilization of anodized layers forming the internal surfaces of the container volume. Bias resistors are calibrated to provide constant current at variable voltage conditions. By choosing the appropriate values of the bias resistors, the voltages of the metallic container relative to the voltage of an anode are adjusted to achieve optimal plasma fill while minimizing the chance of reaching the breakdown voltage of the anodized layer.
Liquid chromatographic determination of florfenicol in the plasma of multiple species of fish
Vue, C.; Schmidt, L.J.; Stehly, G.R.; Gingerich, W.H.
2002-01-01
A simple method was developed for determining florfenicol concentration in a small volume (250 mul) of plasma from five phylogenetically diverse species of freshwater fish. Florfenicol was isolated from the plasma matrix through C-18 solid-phase extraction and quantified by reversed-phase high-performance liquid chromatography with UV detection. The accuracy (84-104%), precision (%RSDless than or equal to8), and sensitivity (quantitation limit <30 ng/ml) of the method indicate its usefulness for conducting pharmacokinetic studies on a variety of freshwater fish. Published by Elsevier Science B.V.
Theoretical Modeling of the Interior Ballistics of the Electrothermal Gun
1993-07-01
latter one 19 Table 2.1 Parameters Used for Nominal Data Base (after Oberle [2]). Chamber Volume 97.108 cm 3 Projectile Travel 145 cm Bore Diameter 14...at the time when the plasma supply is completed. When this occurs in the case of instantaneous mixing one has the projectile travel reduced by... Travel 400.0 cm Bore Diameter 4.0 cm Projectile Hass 160 g Plasma Energy 2000000 J Plasma Mass 0.0 g Working Fluid 420 g of H20 Density I g/cm. Bulk
Simulation of Self-consistent Radio Wave Artificial Ionospheric Turbulence Pumping and Damping
NASA Astrophysics Data System (ADS)
Kochetov, Andrey
The numerical simulations of the action of self-consistent incident powerful electromagnetic wave absorption arising in the regions of artificial plasma turbulence excitation at formation, saturation and relaxation stages of turbulent structures (Kochetov, A.V., Mironov, V.A., Te-rina, G.I., Bubukina V. N, Physica D, Nonlinear phenomena, 2001, 152-153, 723) to reflection index dynamics are carried out. The nonlinear Schrüdinger equation in inhomogeneous plasma layer with incident electromagnetic wave pumping and backscattered radiation damping (Ko-chetov, et al, Adv. Space Res., 2002, 29, 1369 and 2006, 38, 2490) is extended with the imagi-nary part of plasma dielectric constant (volume damping), which is should be taken into account in strong electromagnetic field plasma regions and results the energy transformation from elec-tromagnetic waves to plasma ones at resonance interaction (D.V. Shapiro, V.I. Shevchenko, in Handbook of Plasma Physics 2, eds. A.A Galeev, R.N. Sudan. Elsevier, Amsterdam, 1984). The volume damping reproduces the basic energy transformation peculiarities: hard excitation, nonlinearity, hysteresis (A.V. Kochetov, E. Mjoelhus, Proc. of IV Intern. Workshop "SMP", Ed. A.G. Litvak, Vol.2, N. Novgorod, 2000, 491). Computer modeling demonstrates that the amplitude and period of reflection index oscillations at the formation stage slowly depend on damping parameters of turbulent plasma regions. The transformation from complicated: quasi-periodic and chaotic dynamics, to quasi-stationary regimes is shown at the saturation stage. Transient processes time becomes longer if the incident wave amplitude and nonlinear plasma response increase, but damping decreases. It is obtained that the calculated reflection and absorption index dynamics at the beginning of the saturation stage agrees qualitatively to the experimental results for ionosphere plasma modification study (Thide B., E.N. Sergeev, S.M. Grach, et. al., Phys. Rev. Lett., 2005, 95, 255002). The work was supported in part by RFBR grant 09-02-01150-a.
Radioimmunoassay for pyridostigmine
DOE Office of Scientific and Technical Information (OSTI.GOV)
Meyer, H.G.; Lukey, B.J.; Gepp, R.T.
1988-01-01
Pyridostigmine is a cholinergic drug used for the treatment of myasthenia gravis and for antagonizing the effects of non-depolarizing muscle relaxants. In addition, military organizations in several countries have an active interest in pyridostigmine as a pretreatment compound for nerve agent poisoning. Anti-pyridostigmine antibodies were produced in rabbits using a pyridostigmine analog conjugated to keyhole limpet hemocyanin. These antibodies were used for development of a radioimmunoassay that has a linear standard curve (r2=0.986) ranging from 0.5 to 10.0 ng/ml of pyridostigmine bromide in a 0.1-ml plasma sample. This assay measures pyridostigmine in plasma with better sensitivity and much greater through-putmore » than do current state-of-the-art high-performance liquid chromatography techniques. In addition, only small volumes (100ml) of the plasma samples are required. Plasma levels of pyridostigmine were determined in the rat after intramuscular administration (0.056mg/kg) of pyridostigmine bromide. Estimates of the various pharmacokinetic parameters were calculated using the computer program NONLIN84. The results were as follows: apparent volume of distribution = 1.97 1/kg, absorption rate constant = 0.277 min-1, elimination rate constant = 0.0273 min-1, area under the curve = 1010 ng x min/ml, absorption rate half-life = 2.41 min, elimination rate half-life = 24.8 min, maximal plasma concentration (Cmax) = 21.3 ng/ml and time to Cmax = 9.02 min.« less
Catecholaminergic effects of prolonged head-down bed rest
NASA Technical Reports Server (NTRS)
Goldstein, D. S.; Vernikos, J.; Holmes, C.; Convertino, V. A.
1995-01-01
Prolonged head-down bed rest (HDBR) provides a model for examining responses to chronic weightlessness in humans. Eight healthy volunteers underwent HDBR for 2 wk. Antecubital venous blood was sampled for plasma levels of catechols [norepinephrine (NE), epinephrine, dopamine, dihydroxyphenylalanine, dihydroxyphenylglycol, and dihydroxyphenylacetic acid] after supine rest on a control (C) day and after 4 h and 7 and 14 days of HDBR. Urine was collected after 2 h of supine rest during day C, 2 h before HDBR, and during the intervals 1-4, 4-24, 144-168 (day 7), and 312-336 h (day 14) of HDBR. All subjects had decreased plasma and blood volumes (mean 16%), atriopeptin levels (31%), and peripheral venous pressure (26%) after HDBR. NE excretion on day 14 of HDBR was decreased by 35% from that on day C, without further trends as HDBR continued, whereas plasma levels were only variably and nonsignificantly decreased. Excretion rates of dihydroxyphenylglycol and dihydroxyphenylalanine decreased slightly during HDBR; excretion rates of epinephrine, dopamine, and dihydroxyphenylacetic acid and plasma levels of catechols were unchanged. The results suggest that HDBR produces sustained inhibition of sympathoneural release, turnover, and synthesis of NE without affecting adrenomedullary secretion or renal dopamine production. Concurrent hypovolemia probably interferes with detection of sympathoinhibition by plasma levels of NE and other catechols in this setting. Sympathoinhibition, despite decreased blood volume, may help to explain orthostatic intolerance in astronauts returning from spaceflights.
Weiner, Myron F; de la Plata, Carlos Marquez; Fields, B A Julie; Womack, Kyle B; Rosenberg, Roger N; Gong, Yun-Hua; Qu, Bao-Xi; Diaz-Arrastia, Ramon; Hynan, Linda S
2009-02-01
We obtained brain MRIs, plasma homocysteine levels and apolipoprotein E genotyping for 11 American Indian Alzheimer disease (AD) subjects and 10 Indian controls. We calculated white matter hyperintensity volume (WMHV), whole brain volume (WBV), and ratio of white matter hyperintensity volume to whole brain volume (WMHV/WBV). There were no significant differences between AD subjects and controls in gender, history of hypertension, diabetes, or history of high cholesterol, but hypertension and diabetes were more common among AD subjects. There was no difference between AD and control groups in age (range for all subjects was 61-89 years), % Indian heritage, waist size or body mass index. Median Indian heritage was 50% or greater in both groups. Range of education was 5-13 years in the AD group and 12-16 years in controls. Median plasma homocysteine concentration was higher in AD subjects (11 micromol/L vs. 9.8 micromol/L), but did not achieve statistical significance. Significantly more AD subjects had apolipoprotein Eepsilon4 alleles than did controls (63% vs.10%). Neuroimaging findings were not significantly different between the 2 groups, but AD subjects had greater WMHV (median 15.64 vs. 5.52 cc) and greater WMHV/WBV ratio (median 1.63 vs. 0.65 %) and a far greater range of WMHV. In combined AD subjects and controls, WBV correlated with BMI and age. WMHV and WMHV/WBV correlated inversely with MMSE scores (p = 0.001, 0.002, respectively). In addition, WMHV correlated positively with % Indian heritage (p = 0.047).
Haslene-Hox, Hanne; Oveland, Eystein; Woie, Kathrine; Salvesen, Helga B; Tenstad, Olav; Wiig, Helge
2015-01-01
Elements of the extracellular matrix (ECM), notably collagen and glucosaminoglycans, will restrict part of the space available for soluble macromolecules simply because the molecules cannot occupy the same space. This phenomenon may influence macromolecular drug uptake. To study the influence of steric and charge effects of the ECM on the distribution volumes of macromolecules in human healthy and malignant gynecologic tissues we used as probes 15 abundant plasma proteins quantified by high-resolution mass spectrometry. The available distribution volume (VA) of albumin was increased in ovarian carcinoma compared with healthy ovarian tissue. Furthermore, VA of plasma proteins between 40 and 190 kDa decreased with size for endometrial carcinoma and healthy ovarian tissue, but was independent of molecular weight for the ovarian carcinomas. An effect of charge on distribution volume was only found in healthy ovaries, which had lower hydration and high collagen content, indicating that a condensed interstitium increases the influence of negative charges. A number of earlier suggested biomarker candidates were detected in increased amounts in malignant tissue, e.g., stathmin and spindlin-1, showing that interstitial fluid, even when unfractionated, can be a valuable source for tissue-specific proteins. We demonstrate that the distribution of abundant plasma proteins in the interstitium can be elucidated by mass spectrometry methods and depends markedly on hydration and ECM structure. Our data can be used in modeling of drug uptake, and give indications on ECM components to be targeted to increase the uptake of macromolecular substances. Copyright © 2015 the American Physiological Society.
NASA Astrophysics Data System (ADS)
Reece Roth, J.
2004-11-01
The majority of industrial plasma processing with glow discharges has been conducted at pressures below 10 torr. This tends to limit applications to high value workpieces as a result of the high capital cost of vacuum systems and the production constraints of batch processing. It has long been recognized that glow discharge plasmas would play a much larger industrial role if they could be generated at one atmosphere. The One Atmosphere Uniform Glow Discharge Plasma (OAUGDP), developed at the University of Tennessee's Plasma Sciences Laboratory, is a non-thermal RF plasma operating on displacement currents with the time-resolved characteristics of a classical low pressure DC normal glow discharge. As a glow discharge, the OAUGDP operates with maximum electrical efficiency at the Stoletow point, where the energy input per ion-electron pair is a minimum [1, 2]. Several interdisciplinary teams have investigated potential applications of the OAUGDP. These teams included collaborators from the UTK Textiles and Nonwovens Development Center (TANDEC), and the Departments of Electrical and Computer Engineering, Microbiology, and Food Science and Technology, as well as the NASA Langley Research Center. The potential applications of the OAUGDP have all been at one atmosphere and room temperature, using air as the working gas. These applications include sterilizing medical and dental equipment; sterilizable air filters to deal with the "sick building syndrome"; removal of soot from Diesel engine exhaust; subsonic plasma aerodynamic effects, including flow re-attachment to airfoils and boundary layer modification; electrohydrodynamic (EDH) flow control of working gases; increasing the surface energy of materials; improving the adhesion of paints and electroplated layers: improving the wettability and wickability of fabrics; stripping of photoresist; and plasma deposition and directional etching of potential microelectronic relevance. [1] J. R. Roth, Industrial Plasma Engineering: Volume I, Principles. Institute of Physics Publishing, Bristol and Philadelphia 1995, ISBN 0-7503-0318-2. [2] Roth, J. R. Industrial Plasma Engineering: Volume II Applications to Nonthermal Plasma Processing Institute of Physics Publishing, Bristol and Philadelphia. 2001, ISBN 0-7503-0545-2.
Comparison of hormone and electrolyte circadian rhythms in male and female humans
NASA Technical Reports Server (NTRS)
Vernikos-Danellis, J.; Winget, C. M.; Goodwin, A. E.; Reilly, T.
1977-01-01
Circadian rhythm characteristics in healthy male and female humans were studied at 4-hour intervals for urine volume, cortisol, 5-hydroxyindoleacetic acid (5-HIAA), Na, K, Na/K ratios in the urine, as well as plasma cortisol. While plasma and urinary cortisol rhythms were very similar in both sexes, the described rhythms in urine volume, electrolyte, and 5-HIAA excretion differ for the two sexes. The results suggest that sex differences exist in the circadian patterns of important hormone and metabolic functions and that the internal synchrony of circadian rhythms differs for the two sexes. The results seem to indicate that the rhythmical secretion of cortisol does not account for the pattern of Na and K excretion.
Apparatus for the plasma destruction of hazardous gases
Kang, M.
1995-02-07
A plasma cell for destroying hazardous gases is described. An electric-discharge cell having an electrically conducting electrode onto which an alternating high-voltage waveform is impressed and a dielectric barrier adjacent thereto, together forming a high-voltage electrode, generates self-terminating discharges throughout a volume formed between this electrode and a grounded conducting liquid electrode. The gas to be transformed is passed through this volume. The liquid may be flowed, generating thereby a renewable surface. Moreover, since hydrochloric and hydrofluoric acids may be formed from destruction of various chlorofluorocarbons in the presence of water, a conducting liquid may be selected which will neutralize these corrosive compounds. The gases exiting the discharge region may be further scrubbed if additional purification is required. 4 figs.
Apparatus for the plasma destruction of hazardous gases
Kang, Michael
1995-01-01
A plasma cell for destroying hazardous gases. An electric-discharge cell having an electrically conducting electrode onto which an alternating high-voltage waveform is impressed and a dielectric barrier adjacent thereto, together forming a high-voltage electrode, generates self-terminating discharges throughout a volume formed between this electrode and a grounded conducting liquid electrode. The gas to be transformed is passed through this volume. The liquid may be flowed, generating thereby a renewable surface. Moreover, since hydrochloric and hydrofluoric acids may be formed from destruction of various chlorofluorocarbons in the presence of water, a conducting liquid may be selected which will neutralize these corrosive compounds. The gases exiting the discharge region may be further scrubbed if additional purification is required.
Perrotta, Alberto; Fuentes-Hernandez, Canek; Khan, Talha M.; ...
2016-12-02
Plasma-assisted atomic layer deposition (ALD) is used for the deposition of environmental barriers directly onto organic photovoltaic devices (OPVs) at near room temperature (30 °C). To study the effect of the ALD process on the organic materials forming the device, the precursor diffusion and intermixing at the interface during the growth of different plasma- assisted ALD inorganic barriers (i.e. Al2O3 and TiO2) onto the organic photoactive layer (P3HT:ICBA) was investigated. Depth profile x-ray photoelectron spectroscopy was used to analyze the composition of the organic/inorganic interface to investigate the infiltration of the plasma-assisted ALD precursors into the photoactive layer as amore » function of the precursor dimension, the process temperature, and organic layer morphology. The free volume in the photoactive layer accessible to the ALD precursor was characterized by means of ellipsometric porosimetry (EP) and spectroscopic ellipsometry as a function of temperature. The organic layer is shown to exhibit free volume broadening at high temperatures, increasing the infiltration depth of the ALD precursor into the photoactive layer. Furthermore, based on previous investigations, the intrinsic permeation properties of the inorganic layers deposited by plasma-assisted ALD were predicted from the nano-porosity content as measured by EP and found to be in the 10-6 gm-2 d-1 range. Insight from our studies was used to design and fabricate multilayer barriers synthesized at near-room temperature by plasma-assisted ALD in combination with plasma-enhanced CVD onto organic photovoltaic (OPVs) devices. Encapsulated OPVs displayed shelf-lifetimes up to 1400 h at ambient conditions.« less
NASA Astrophysics Data System (ADS)
Shi, Shukai; Wang, Xin; Chen, Weimin; Chen, Minzhi; Zhou, Xiaoyan
2018-05-01
The as-prepared lignin-based activated carbon (LAC) was post-treated by urea and radio-frequency cold plasma separately. The obtained results demonstrated that the BET surface and total volumes of the LAC and plasma-treated LACs were greater than the urea-modified sample. The analysis of surface elemental composition showed that the nitrogen content of urea-modified LAC and nitrogen plasma-treated LAC are 3.79% and 2.62% higher than that of original LAC respectively, while the oxygen content of air plasma-treated LAC is 10.23% higher than that of original LAC. The Fe(III) ions adsorbed studies with pseudo-second order kinetic model revealed that urea-modified LAC had faster chemisorption rates while air plasma-treated LAC had larger adsorption capacity within 3 h. Moreover, the adsorption capacity and chemisorption rates of LAC post-treated by nitrogen plasma are inferior to the air plasma-treated LAC.
NASA Technical Reports Server (NTRS)
Wang, Zuwei; Vaksman, Zalman; Putcha, Lakshmi
2008-01-01
Intranasal scopolamine is a choice drug for the treatment of motion sickness during space flight because of its quick onset of action, short half-life and favorable sideeffects profile. The dose administered usually ranges between 0.1 and 0.4 mg. Such small doses make it difficult to detect concentrations of scopolamine in biological fluids using existing sensitive LC/MS/MS method, especially when the biological sample volumes are limited. To measure scopolamine in human plasma to facilitate pharmacokinetic evaluation of the drug, we developed a sensitive LC/MS/MS method using 96 well micro elution plates for solid phase extraction (SPE) of scopolamine in human plasma. Human plasma (100-250 micro L) were loaded onto Waters Oasis HLB 96 well micro elution plate and eluted with 50 L of organic solvent without evaporation and reconstitution. HPLC separation of the eluted sample was performed using an Agilent Zorbax SB-CN column (50 x 2.1 mm) at a flow rate of 0.2 mL/min for 3 minutes. The mobile phase for separation was 80:20 (v/v) methanol: ammonium acetate (30 mM) in water. Concentrations of scopolamine were determined using a Micromass Quattro Micro(TM) mass spectrometer with electrospray ionization (ESI). ESI mass spectra were acquired in positive ion mode with multiple reaction monitoring for the determination of scopolamine m/z = 304.2 right arrow 138.1 and internal standard hyoscyamine m/z = 290.2 right arrow 124.1. The method is rapid, reproducible, specific and has the following parameters: scopolamine and the IS are eluted at about 1.1 and 1.7 min respectively. The linear range is 25-10000 pg/mL for scopolamine in human plasma with correlation coefficients greater than 0.99 and CV less than 0.5%. The intra-day and inter-day CVs are less than 15% for quality control samples with concentrations of 75,300, and 750 pg/mL of scopolamine in human plasma. SPE using 96 well micro elution plates allows rapid sample preparation and enhanced sensitivity for the LC/MS/MS determination of scopolamine in a small volume of biological samples. The new method is also cost effective since it uses a small volume of organic solvents compared to the methods using SPE cartridges or regular 96 well SPE plates. This method can be successfully used for bioavailability and pharmacokinetic evaluations of scopolamine, especially when volumes of biological samples are limited. Further investigation to use automated SPE system with 96 well micro elution plates is planned.
LLE Review Quarterly Report (October - December 2007). Volume 113
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zuegel, Jonathan D.
2007-12-01
This volume of the LLE Review, covering October–December 2007, features “High-Intensity Laser–Plasma Interactions in the Refluxing Limit,” by P. M. Nilson, W. Theobald, J. Myatt, C. Stoeckl, M. Storm, O. V. Gotchev, J. D. Zuegel, R. Betti, D. D. Meyerhofer, and T. C. Sangster. In this article (p. 1), the authors report on target experiments using the Multi-Terawatt (MTW) Laser Facility to study isochoric heating of solid-density targets by fast electrons produced from intense, short-pulse laser irradiation. Electron refluxing occurs due to target-sheath field effects and contains most of the fast electrons within the target volume. This efficiently heats themore » solid-density plasma through collisions. X-ray spectroscopic measurements of absolute K α (x-radiation) photon yields and variations of the K β/K α b emission ratio both indicate that laser energy couples to fast electrons with a conversion efficiency of approximately 20%. Bulk electron temperatures of at least 200 eV are inferred for the smallest mass targets.« less
Changes in plasma volume during bed rest - Effects of menstrual cycle and estrogen administration
NASA Technical Reports Server (NTRS)
Fortney, S. M.; Beckett, W. S.; Carpenter, A. J.; Davis, J.; Drew, H.
1988-01-01
The effect of increased blood estrogen concentration, caused either during normal menstrual cycles or by exogenous administration of premarin, on the bed-rest (BR) induced decrease in plasma volume (PV) was investigated. In women who underwent duplicate 11-day BR without estrogen supplementation, the PV was found to decrease significantly, during the first 5 days of BR, to a lower level at which it remained for the rest of the BR period. In women who began BR in the periovulatory stage of the menstrual cycle, the loss of PV was delayed, while women who began BR during other stages of the cycle exhibited the usual trend of the PV decrease during the BR. In women who underwent a single 12-day BR period while taking premarin (1.25 mg/day), PV was found to decrease during the first 4-5 days of BR, but then returned toward the pre-BR level during the remainder of the BR, indicating that estrogens have a role in stabilizing body fluid volume.
NASA Astrophysics Data System (ADS)
Sinha, Bikash; Pal, Santanu; Raha, Sibaji
Quark-Gluon Plasma (QGP) is a state of matter predicted by the theory of strong interactions - Quantum Chromodynamics (QCD). The area of QGP lies at the interface of particle physics, field theory, nuclear physics and many-body theory, statistical physics, cosmology and astrophysics. In its brief history (about a decade), QGP has seen a rapid convergence of ideas from these previously diverging disciplines. This volume includes the lectures delivered by eminent specialists to students without prior experience in QGP. Each course thus starts from the basics and takes the students by steps to the current problems. The chapters are self-contained and pedagogic in style. The book may therefore serve as an introduction for advanced graduate students intending to enter this field or for physicists working in other areas. Experts in QGP may also find this volume a handy reference. Specific examples, used to elucidate how theoretical predictions and experimentally accessible quantities may not always correspond to one another, make this book ideal for self-study for beginners. This feature will also make the volume thought-provoking for QGP practitioners.
23RD International Conference on Phenomena in Ionized Gases, Volume 3
1998-12-01
discharges, and high pressure glows; arcs; high frequency discharges; ionospheric magnetospheric, and astrophysical plasmas; plasma diagnostic methods ...kf) in pulse reflectometry. Second, it different frequencies , and an Abel inversion is gives a quantitative model of the behaviour of the wave... design V method in the case of narrow mutual pitch of surface electrodes for high concentration ozone generation. 2. Experimental setup 20 The electrode
Miller, Wayne L
2017-01-01
Volume overload and fluid congestion remain primary clinical challenges in the assessment and management of patients with chronic heart failure (HF). The pathophysiology of volume regulation is complex, and the simple concept of passive intravascular fluid accumulation is not adequate. The dynamics of interstitial and intravascular fluid compartment interactions and fluid redistribution from venous splanchnic beds to the central pulmonary circulation need to be taken into account in strategies of volume management. Clinical bedside evaluations and right heart hemodynamic assessments can alert of changes in volume status, but only the quantitative measurement of total blood volume can help identify the heterogeneity in plasma volume and red blood cell mass that are features of volume overload in chronic HF. The quantitative assessment of intravascular volume is an effective tool to help guide individualized, appropriate therapy. Not all volume overload is the same, and the measurement of intravascular volume identifies heterogeneity to guide tailored therapy.
Body water compartments during bed rest: Evaluation of analytical methods
NASA Technical Reports Server (NTRS)
Young, H. L.; Juhos, L.; Castle, B. L.; Yusken, J.; Greenleaf, J. E.
1973-01-01
Nine healthy young men were studied to determine the reproducibility and interchangeability of the use of radio-iodinated human serum albumin and Evans Blue dye for estimating plasma volume, sodium bromide for extracellular fluid volume, and deuterium oxide for total body water volume. All subjects were tested in a semibasal condition and allowed to rest for at least 30 min. after arriving at the laboratory. The results indicate that there was uniform distribution of I131 and Evans Blue dye 10 min. after injection and of NaBr and D2O 3 hours after oral ingestion; the buildup of residual tracer did not interfere appreciably with the measurement of either or Evans Blue spaces when they are administered at equal intervals, and the buildup of background tracer after ingestion of NaBr and D2O once per week for three consecutive weeks did not affect the accuracy of the measurement. It was found that I131 and Evans Blue may be used interchangeably for estimating plasma volume; for estimating bromide and D2O spaces, one 3-hour equilibrium blood sample gives results similar to the extrapolation of multiple samples.
NASA Technical Reports Server (NTRS)
Waters, Wendy W.; Ziegler, Michael G.; Meck, Janice V.
2001-01-01
About 20% of astronauts suffer post-spaceflight presyncope, but the underlying etiology remains elusive. We studied responses to standing in 36 astronauts before and after spaceflight (5- 16 days). Individuals were separated into presyncopal women, presyncopal men, and non-presyncopal men based on their ability to stand for 10 min postflight. Preflight, presyncopal women and presyncopal men had low vascular resistance, with the women having the lowest. Postflight, women experienced significantly higher rates of presyncope (P<0.01) and significantly greater losses of plasma volume than the men (P<0.05). Both presyncopal women and men had lower standing arterial pressure (P<=0.001) and vascular resistance (P<0.05), smaller increases in norepinephrine (P<=0.058) and greater increases in epinephrine (P<=0.058) than nonpresyncopal men. Both presyncopal groups had a strong dependence (P<=0.05) on plasma volume to maintain standing stroke volume. These findings suggest that postflight presyncope is ascribed to a combination of inherently low resistance responses, a strong dependence on volume status, and spaceflight-induced hypoadrenergic responses. In contrast, high vascular resistance and spaceflight-induced hyperadrenergic responses prevent presyncope.
NASA Technical Reports Server (NTRS)
Waters, Wendy W.; Ziegler, Michael G.; Meck, Janice V.
2002-01-01
About 20% of astronauts suffer postspaceflight presyncope. We studied pre- to postflight (5- to 16-day missions) cardiovascular responses to standing in 35 astronauts to determine differences between 1) men and women and 2) presyncopal and nonpresyncopal groups. The groups were presyncopal women, presyncopal men, and nonpresyncopal men based on their ability to stand for 10 min postflight. Preflight, women and presyncopal men had low vascular resistance, with the women having the lowest. Postflight, women experienced higher rates of presyncope (100 vs. 20%; P = 0.001) and greater losses of plasma volume (20 vs. 7%; P < 0.05) than men. Also, presyncopal subjects had lower standing mean arterial pressure (P < or = 0.001) and vascular resistance (P < 0.05), smaller increases in norepinephrine (P < or = 0.058) and greater increases in epinephrine (P < or = 0.058) than nonpresyncopal subjects. Presyncopal subjects had a strong dependence on plasma volume to maintain standing stroke volume. These findings suggest that postflight presyncope is greatest in women, and this can be ascribed to a combination of inherently low-resistance responses, a strong dependence on volume status, and relative hypoadrenergic responses. Conversely, high vascular resistance and postflight hyperadrenergic responses prevent presyncope.
Cheng, Chen; Liu, Xin-wei; Du, Fei-fei; Li, Mei-juan; Xu, Fang; Wang, Feng-qing; Liu, Yang; Li, Chuan; Sun, Yan
2013-01-01
Aim: Both Borneolum (Chinese name Bingpian; dextrorotatory borneol) and Borneolum syntheticum (synthetic Bingpian; a mixture of optically inactive borneol and isoborneol) have been used for medicinal purposes in Chinese traditional medicine. The aim of this study was to develop a sensitive assay for measuring volatile ingredients borneol, isoborneol, and their metabolite camphor in pharmacokinetic study of Bingpian. Methods: Rat plasma samples were prepared using liquid-liquid microextraction: 70 μL of plasma sample (containing 125 nmol/L naphthalene as the internal standard) was extracted with 35 μL of n-hexane. The resulting n-hexane extract (20 μL) was introduced into a gas chromatography/mass spectrometry system using programmable temperature vaporizing-based large-volume injection. The assay was validated to demonstrate its reliability for the intended use. Using this assay, pharmacokinetic studies of Bingpian, synthetic Bingpian, and Fufang-Danshen tablets (containing synthetic Bingpian) were conducted in rats. Results: The extraction efficiency for the analytes and the internal standard from plasma was almost constant with decrease in n-hexane-to-plasma volume ratio, thus enabling a small volume of extracting solvent to be used for sample preparation, and enhancing the assay sensitivity. The lower quantification limit for measuring borneol, isoborneol, and camphor in plasma was 0.98 nmol/L, which was 33–330 times more sensitive than those reported earlier for Bingpian and synthetic Bingpian. The applicability of the miniaturized liquid-liquid extraction technique could be extended to measure other volatile and nonvolatile medicinal compounds in biomatrices, which can be predicted according to the analytes' octanol/water distribution coefficient (logD) and acid dissociation constant (pKa). Conclusion: This assay is sensitive, accurate and free of matrix effects, and can be applied to pharmacokinetic studies of Bingpian, synthetic Bingpian, and Bingpian-containing herbal products. PMID:23974515
Kimura, Yuichi; Seki, Chie; Hashizume, Nobuya; Yamada, Takashi; Wakizaka, Hidekatsu; Nishimoto, Takahiro; Hatano, Kentaro; Kitamura, Keishi; Toyama, Hiroshi; Kanno, Iwao
2013-11-21
This study aimed to develop a new system, named CD-Well, for mouse PET dynamic study. CD-Well allows the determination of time-activity curves (TACs) for arterial whole blood and plasma using 2-3 µL of blood per sample; the minute sample size is ideal for studies in small animals. The system has the following merits: (1) measures volume and radioactivity of whole blood and plasma separately; (2) allows measurements at 10 s intervals to capture initial rapid changes in the TAC; and (3) is compact and easy to handle, minimizes blood loss from sampling, and delay and dispersion of the TAC. CD-Well has 36 U-shaped channels. A drop of blood is sampled into the opening of the channel and stored there. After serial sampling is completed, CD-Well is centrifuged and scanned using a flatbed scanner to define the regions of plasma and blood cells. The length measured is converted to volume because the channels have a precise and uniform cross section. Then, CD-Well is exposed to an imaging plate to measure radioactivity. Finally, radioactivity concentrations are computed. We evaluated the performance of CD-Well in in vitro measurement and in vivo (18)F-fluorodeoxyglucose and [(11)C]2-carbomethoxy-3β-(4-fluorophenyl) tropane studies. In in vitro evaluation, per cent differences (mean±SE) from manual measurement were 4.4±3.6% for whole blood and 4.0±3.5% for plasma across the typical range of radioactivity measured in mouse dynamic study. In in vivo studies, reasonable TACs were obtained. The peaks were captured well, and the time courses coincided well with the TAC derived from PET imaging of the heart chamber. The total blood loss was less than 200 µL, which had no physiological effect on the mice. CD-Well demonstrates satisfactory performance, and is useful for mouse PET dynamic study.
Li, Jingxia; Mu, Shuangfeng; Mu, Lixiang; Zhang, Xiaohui; Pang, Ranran; Gao, Shegan
2015-01-01
To examine the relationship between cytokine levels of transforming growth factor-beta-1 (TGF-β1), interleukin-1 beta (IL-1β), and angiotensin-converting enzyme (ACE) in the plasma of esophageal carcinoma patients and radiation-induced pneumonitis (RP). Sixty-three patients with esophageal carcinoma were treated with three-dimensional conformal radiotherapy (RT) using the Elekta Precise treatment planning system with a prescribed dose of 50-70 Gy. Dose-volume histograms were collected from three-dimensional conformal RT to determine the volume percentage of the lung received V5, V10, V20, and the normal tissue complication probability. RP was diagnosed based on computed tomography imaging, respiratory symptoms, and signs. The severity of radiation-induced lung toxicity was determined using the Lent-Soma scale defined by the Radiation Therapy Oncology Group. Plasma samples obtained before RT, during RT (at 40 Gy), and at 1 day, 1 month, and 3 months after RT were assayed for TGF-β1, IL-1β, and ACE levels by enzyme-linked immunosorbent assay. From the 63 patients, 17 (27%) developed RP, and 13 (21%) had RP of grade I and four (6%) had grade II or higher. We found plasma TGF-β1 levels were elevated in the patients that had RP when compared with the other 46 patients who did not have RP. The plasma IL-1β levels were not changed. The ACE levels were significantly lower in the 17 patients with RP compared to the 46 patients without RP throughout the RT. As expected, RP is associated with a higher dose of irradiation (>60 Gy); no other factors, including dose-volume histogram, age, sex, smoking status, location of tumor, and methods of treatment, are associated with RP. Elevated plasma TGF-β1 levels can be used as a marker for RP.
Electron density measurements in STPX plasmas
NASA Astrophysics Data System (ADS)
Clark, Jerry; Williams, R.; Titus, J. B.; Mezonlin, E. D.; Akpovo, C.; Thomas, E.
2017-10-01
Diagnostics have been installed to measure the electron density of Spheromak Turbulent Physics Experiment (STPX) plasmas at Florida A. & M. University. An insertable probe, provided by Auburn University, consisting of a combination of a triple-tipped Langmuir probe and a radial array consisting of three ion saturation current / floating potential rings has been installed to measure instantaneous plasma density, temperature and plasma potential. As the ramp-up of the experimental program commences, initial electron density measurements from the triple-probe show that the electron density is on the order of 1019 particles/m3. For a passive measurement, a CO2 interferometer system has been designed and installed for measuring line-averaged densities and to corroborate the Langmuir measurements. We describe the design, calibration, and performance of these diagnostic systems on large volume STPX plasmas.
Experimental observation of electron-temperature-gradient turbulence in a laboratory plasma.
Mattoo, S K; Singh, S K; Awasthi, L M; Singh, R; Kaw, P K
2012-06-22
We report the observation of electron-temperature-gradient (ETG) driven turbulence in the laboratory plasma of a large volume plasma device. The removal of unutilized primary ionizing and nonthermal electrons from uniform density plasma and the imposition and control of the gradient in the electron temperature (T[Symbol: see text] T(e)) are all achieved by placing a large (2 m diameter) magnetic electron energy filter in the middle of the device. In the dressed plasma, the observed ETG turbulence in the lower hybrid range of frequencies ν = (1-80 kHz) is characterized by a broadband with a power law. The mean wave number k perpendicular ρ(e) = (0.1-0.2) satisfies the condition k perpendicular ρ(e) ≤ 1, where ρ(e) is the electron Larmor radius.
Porcelain-coated antenna for radio-frequency driven plasma source
Leung, Ka-Ngo; Wells, Russell P.; Craven, Glen E.
1996-01-01
A new porcelain-enamel coated antenna creates a clean plasma for volume or surface-conversion ion sources. The porcelain-enamel coating is hard, electrically insulating, long lasting, non fragile, and resistant to puncture by high energy ions in the plasma. Plasma and ion production using the porcelain enamel coated antenna is uncontaminated with filament or extraneous metal ion because the porcelain does not evaporate and is not sputtered into the plasma during operation. Ion beams produced using the new porcelain-enamel coated antenna are useful in ion implantation, high energy accelerators, negative, positive, or neutral beam applications, fusion, and treatment of chemical or radioactive waste for disposal. For ion implantation, the appropriate species ion beam generated with the inventive antenna will penetrate large or small, irregularly shaped conducting objects with a narrow implantation profile.
Variable frequency matching to a radiofrequency source immersed in vacuum
NASA Astrophysics Data System (ADS)
Charles, C.; Boswell, R. W.; Bish, A.
2013-09-01
A low-weight (0.12 kg) low-volume fixed ceramic capacitor impedance matching system is developed for frequency agile tuning of a radiofrequency (rf) Helicon plasma thruster. Three fixed groups of capacitors are directly mounted onto a two loop rf antenna with the thruster immersed in a vacuum chamber. Optimum plasma tuning at the resonance frequency is demonstrated via measurements of the load impedance, power transfer efficiency and plasma density versus driving frequency in the 12.882-14.238 MHz range. The resonance frequency with the plasma on is higher than the resonance frequency in vacuum. The minimum rf power necessary for ignition decreases when the ignition frequency is shifted downwards from the resonance frequency. This development has direct applications in space qualification and space use of rf plasma thrusters.
Dresser, George K; Kim, Richard B; Bailey, David G
2005-03-01
The purpose of this study was to elucidate the potential clinical relevance and mechanism(s) of action of 2 different volumes of grapefruit juice on the reduction of bioavailability of fexofenadine, a substrate of organic anion transporting polypeptides. Grapefruit juice or water at normal (300 mL) or high (1200 mL) volume was ingested concomitantly with 120 mg fexofenadine by 12 healthy volunteers in a randomized 4-way crossover study, and fexofenadine pharmacokinetics were determined over a period of 8 hours. The 300-mL volume of grapefruit juice decreased the mean area under the plasma drug concentration-time curve (AUC) and the peak plasma drug concentration of fexofenadine to 58% (P < .001) and 53% (P < .001), respectively, of those with the corresponding volume of water, and 1200 mL grapefruit juice reduced these parameters to 36% ( P < .001) and 33% ( P < .001), respectively, of those with the corresponding volume of water. The 300-mL volume of grapefruit juice diminished the AUC of fexofenadine variably among individuals. This decline correlated with baseline AUC of fexofenadine with water at equivalent volume (r(2) = 0.97, P < .0001). The 1200-mL volume of grapefruit juice decreased the AUC of fexofenadine more than the 300-mL volume of grapefruit juice compared with the corresponding volume of water in each subject by a constant amount. Grapefruit juice, 300 mL and 1200 mL, reduced the coefficient of variation of the AUC of fexofenadine by 2-fold compared with that with a matching volume of water. Grapefruit juice at a commonly consumed volume diminished the oral bioavailability of fexofenadine sufficiently to be pertinent clinically, likely by direct inhibition of uptake by intestinal organic anion transporting polypeptide A (OATP-A; new nomenclature, OATP1A2). A much higher volume caused an additional modest effect, possibly from reduced intestinal concentration and transit time of fexofenadine. This food-drug interaction appears to be novel and may be relevant to other fruit juices and drugs.
PREFACE: 13th High-Tech Plasma Processes Conference (HTPP-2014)
NASA Astrophysics Data System (ADS)
2014-11-01
The High-Tech Plasma Processes - 13th European Plasma Conference (HTPP-2014) was held in Toulouse (France) on 22-27 June 2014. The conference series started in 1990 as a thermal plasma conference and has gradually expanded to include other related topics. Now the High-Tech Plasma Processes - European Plasma Conference (HTPP) is an international conference organised in Europe every two years with topics encompassing the whole field of plasma processing science. The aim of the conference is to bring different scientific communities together, to facilitate contacts between science, technology and industry and to provide a platform for the exploration of both the fundamental topics and new applications of plasmas. For this edition of HTPP, as was the case for the last, we have acheived a well balanced participation from the communities of both thermal and non-thermal plasma researchers. 142 people from 17 countries attended the conference with the total number of contributions being 155, consisting of 8 plenary and 8 invited talks plus 51 oral and 88 poster contributions. We have received numerous papers corresponding to the contributions of HTPP-2014 that have been submitted for publication in this volume of Journal of Physics: Conference Series. Each submitted contribution has been peer reviewed (60 referees with at least two reviewing each paper) and the Editors are very grateful to the referees for their careful support in improving the original manuscripts. In total, 52 manuscripts have been accepted for publication covering a range of topics of plasma processing science from plasma fundamentals to process applications through to experiments, diagnostics and modelling. We have grouped the papers into the following 5 topics: - Arc-Materials Interaction and Metallurgy - Plasma Torches and Spraying - Synthesis of Powders and Nanomaterials - Deposition and Surface Treatment - Non-Equilibrium Plasmas We deeply thank the authors for their enthusiastic and high-grade contributions and we are convinced that this volume of Journal of Physics: Conference Series will be interesting for our community. Finally, we would like to thank the conference chairmen, the members of the steering committee, the international scientific committee, the local organizing committee, the organizing secretariat and the financial support from the conference sponsors that allowed the success of HTPP-2014. The Editors of the HTPP-2014 Proceedings Dr Alain Gleizes, chairman of HTPP-2014 Prof. Jochen Schein, head of the ISC Prof. Philippe Teulet Toulouse, 14th October 2014
Johnson, L; Kwok, M; Marks, D C
2015-02-01
The ErySep system represents an alternative to centrifuge-based whole blood (WB) separation, using gravity and filtration through hollow-fibres (0·2 µm pore size) to produce red blood cell (RBC) and plasma components. The aim of this study was to characterise the quality of ErySep RBC and plasma units compared with standard products from WB held overnight. Two ABO-compatible WB units (n = 24) were pooled and split to produce matched products. One of the WB units was separated into components using the ErySep system (ErySep; n = 12), whereas the other units were separated by centrifugation (control; n = 12). RBC units were stored at 2-6 °C and assessed for in vitro quality over 42 days of storage. Plasma was frozen at -30 °C and tested upon thawing. Processing WB with the ErySep system took longer than controls. The ErySep RBC units were of an appropriate volume (307 ± 17 mL) and contained sufficient Hb (50 ± 2 g unit(-1) ). ErySep RBC components contained more microparticles relative to controls at expiry. The plasma volume, total protein, coagulation factor activity (fibrinogen, FV, FVIII) and number of microparticles was lower in the ErySep units compared with controls. Following overnight hold of WB, the ErySep system was capable of producing RBC components that met specifications. However, the ErySep plasma components did not meet quality specifications. © 2015 British Blood Transfusion Society.
Chandrashekar, Devaraj V; Suresh, Ponnayyan S; Kumar, Rajnish; Bhamidipati, Ravi Kanth; Mullangi, Ramesh; Richter, Wolfgang; Srinivas, Nuggehally R
2017-09-01
A highly sensitive, specific and rapid LC-ESI-MS/MS method has been developed and validated for the simultaneous quantification of bendamustine (BM) and γ-hydroxybendamustine (HBM) in small volume (20 µL) mice and dog plasma using phenacetin as an internal standard (IS) as per regulatory guidelines. Both the analytes and IS were extracted from mice and dog plasma using a liquid-liquid extraction method. Chromatography was achieved on Atlantis dC 18 column using an isocratic mobile phase (0.2% formic acid:acetonitrile, 25:75) at a flow rate of 0.40 mL/min. The total chromatographic run time was 3.0 min and the elution of BM, HBM and IS occurred at ~1.2, 1.2 and 2.0 min, respectively. A linear response function was established 0.11-518 ng/mL for both the analytes in mice and dog plasma. The intra- and inter-day accuracy and precisions were in the range of 3.46-12.9 and 3.63-8.23%; 1.15-9.00 and 7.86-9.49% for BM and HBM, respectively in mice plasma and 2.15-6.49 and 1.73-13.1%; 4.35-13.9 and 4.33-10.5% for BM and HBM, respectively in dog plasma. This novel method has been applied to a pharmacokinetic study in mice and dogs. © Georg Thieme Verlag KG Stuttgart · New York.
Li, Yu-hong; Lou, Xian-feng; Bao, Fang-ping
2006-01-01
Objective: To investigate the dynamics of vascular volume and the plasma dilution of lactated Ringer’s solution in patients during the induction of general and epidural anesthesia. Methods: The hemodilution of i.v. infusion of 1000 ml of lactated Ringer’s solution over 60 min was studied in patients undergoing general (n=31) and epidural (n=22) anesthesia. Heart rate, arterial blood pressure and hemoglobin (Hb) concentration were measured every 5 min during the study. Surgery was not started until the study period had been completed. Results: General anesthesia caused the greater decrease of mean arterial blood pressure (MAP) (mean 15% versus 9%; P<0.01) and thereby followed by a more pronounced plasma dilution, blood volume expansion (VE) and blood volume expansion efficiency (VEE). A strong linear correlation between hemodilution and the reduction in MAP (r=−0.50; P<0.01) was found. At the end of infusion, patients undergoing general anesthesia retained 47% (SD 19%) of the infused fluid in the circulation, while epidural anesthesia retained 29% (SD 13%) (P<0.001). Correspondingly, a fewer urine output (mean 89 ml versus 156 ml; P<0.05) and extravascular expansion (454 ml versus 551 ml; P<0.05) were found during general anesthesia. Conclusion: We concluded that the induction of general anesthesia caused more hemodilution, volume expansion and volume expansion efficiency than epidural anesthesia, which was triggered only by the lower MAP. PMID:16909476
Programmable calculator software for computation of the plasma binding of ligands.
Conner, D P; Rocci, M L; Larijani, G E
1986-01-01
The computation of the extent of plasma binding of a ligand to plasma constituents using radiolabeled ligand and equilibrium dialysis is complex and tedious. A computer program for the HP-41C Handheld Computer Series (Hewlett-Packard) was developed to perform these calculations. The first segment of the program constructs a standard curve for quench correction of post-dialysis plasma and buffer samples, using either external standard ratio (ESR) or sample channels ratio (SCR) techniques. The remainder of the program uses the counts per minute, SCR or ESR, and post-dialysis volume of paired plasma and buffer samples generated from the dialysis procedure to compute the extent of binding after correction for background radiation, counting efficiency, and intradialytic shifts of fluid between plasma and buffer compartments during dialysis. This program greatly simplifies the analysis of equilibrium dialysis data and has been employed in the analysis of dexamethasone binding in normal and uremic sera.
Progress on the Development of the hPIC Particle-in-Cell Code
NASA Astrophysics Data System (ADS)
Dart, Cameron; Hayes, Alyssa; Khaziev, Rinat; Marcinko, Stephen; Curreli, Davide; Laboratory of Computational Plasma Physics Team
2017-10-01
Advancements were made in the development of the kinetic-kinetic electrostatic Particle-in-Cell code, hPIC, designed for large-scale simulation of the Plasma-Material Interface. hPIC achieved a weak scaling efficiency of 87% using the Algebraic Multigrid Solver BoomerAMG from the PETSc library on more than 64,000 cores of the Blue Waters supercomputer at the University of Illinois at Urbana-Champaign. The code successfully simulates two-stream instability and a volume of plasma over several square centimeters of surface extending out to the presheath in kinetic-kinetic mode. Results from a parametric study of the plasma sheath in strongly magnetized conditions will be presented, as well as a detailed analysis of the plasma sheath structure at grazing magnetic angles. The distribution function and its moments will be reported for plasma species in the simulation domain and at the material surface for plasma sheath simulations. Membership Pending.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Huang Hui; Tan, O.K.; Lee, Y.C.
2005-10-17
SnO{sub 2} thin films were deposited by radio-frequency inductively coupled plasma-enhanced chemical vapor deposition. Postplasma treatments were used to modify the microstructure of the as-deposited SnO{sub 2} thin films. Uniform nanorods with dimension of null-set 7x100 nm were observed in the plasma-treated films. After plasma treatments, the optimal operating temperature of the plasma-treated SnO{sub 2} thin films decreased by 80 deg. C, while the gas sensitivity increased eightfold. The enhanced gas sensing properties of the plasma-treated SnO{sub 2} thin film were believed to result from the large surface-to-volume ratio of the nanorods' tiny grain size in the scale comparable tomore » the space-charge length and its unique microstructure of SnO{sub 2} nanorods rooted in SnO{sub 2} thin films.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stamate, E.; Draghici, M.
2012-04-15
A large area plasma source based on 12 multi-dipolar ECR plasma cells arranged in a 3 x 4 matrix configuration was built and optimized for silicon etching by negative ions. The density ratio of negative ions to electrons has exceeded 300 in Ar/SF{sub 6} gas mixture when a magnetic filter was used to reduce the electron temperature to about 1.2 eV. Mass spectrometry and electrostatic probe were used for plasma diagnostics. The new source is free of density jumps and instabilities and shows a very good stability for plasma potential, and the dominant negative ion species is F{sup -}. Themore » magnetic field in plasma volume is negligible and there is no contamination by filaments. The etching rate by negative ions measured in Ar/SF{sub 6}/O{sub 2} mixtures was almost similar with that by positive ions reaching 700 nm/min.« less
NASA Astrophysics Data System (ADS)
Sigeneger, F.; Becker, M. M.; Foest, R.; Loffhagen, D.
2016-09-01
The gas flow and plasma in a miniaturized non-thermal atmospheric pressure plasma jet for plasma enhanced chemical vapour deposition has been investigated by means of hydrodynamic modelling. The investigation focuses on the interplay between the plasma generation in the active zone where the power is supplied by an rf voltage to the filaments, the transport of active plasma particles due to the gas flow into the effluent, their reactions with the thin film precursor molecules and the transport of precursor fragments towards the substrate. The main features of the spatially two-dimensional model used are given. The results of the numerical modelling show that most active particles of the argon plasma are mainly confined within the active volume in the outer capillary of the plasma jet, with the exception of molecular argon ions which are transported remarkably into the effluent together with slow electrons. A simplified model of the precursor kinetics yields radial profiles of precursor fragment fluxes onto the substrate, which agree qualitatively with the measured profiles of thin films obtained by static film deposition experiments.
Paintsil, Elijah; Binka, Mawuena; Patel, Amisha; Lindenbach, Brett D; Heimer, Robert
2014-04-15
Healthcare workers may come into contact with fomites that contain infectious hepatitis C virus (HCV) during preparation of plasma or following placement or removal of venous lines. Similarly, injection drugs users may come into contact with fomites. Hypothesizing that prolonged viability of HCV in fomites may contribute significantly to incidence, we determined the longevity of virus infectivity and the effectiveness of antiseptics. We determined the volume of drops misplaced during transfer of serum or plasma. Aliquots equivalent to the maximum drop volume of plasma spiked with the 2a HCV reporter virus were loaded into 24-well plates. Plates were stored uncovered at 3 temperatures: 4°C, 22°C, and 37°C for up to 6 weeks before viral infectivity was determined in a microculture assay. The mean volume of an accidental drop was 29 µL (min-max of 20-33 µL). At storage temperatures 4°C and 22°C, we recovered viable HCV from the low-titer spots for up to 6 weeks of storage. The rank order of HCV virucidal activity of commonly used antiseptics was bleach (1:10) > cavicide (1:10) > ethanol (70%). The hypothesis of potential transmission from fomites was supported by the experimental results. The anti-HCV activity of commercial antiseptics varied.
Paintsil, Elijah; Binka, Mawuena; Patel, Amisha; Lindenbach, Brett D.; Heimer, Robert
2014-01-01
Background. Healthcare workers may come into contact with fomites that contain infectious hepatitis C virus (HCV) during preparation of plasma or following placement or removal of venous lines. Similarly, injection drugs users may come into contact with fomites. Hypothesizing that prolonged viability of HCV in fomites may contribute significantly to incidence, we determined the longevity of virus infectivity and the effectiveness of antiseptics. Methods. We determined the volume of drops misplaced during transfer of serum or plasma. Aliquots equivalent to the maximum drop volume of plasma spiked with the 2a HCV reporter virus were loaded into 24-well plates. Plates were stored uncovered at 3 temperatures: 4°C, 22°C, and 37°C for up to 6 weeks before viral infectivity was determined in a microculture assay. Results. The mean volume of an accidental drop was 29 µL (min–max of 20–33 µL). At storage temperatures 4°C and 22°C, we recovered viable HCV from the low-titer spots for up to 6 weeks of storage. The rank order of HCV virucidal activity of commonly used antiseptics was bleach (1:10) > cavicide (1:10) > ethanol (70%). Conclusions. The hypothesis of potential transmission from fomites was supported by the experimental results. The anti-HCV activity of commercial antiseptics varied. PMID:24273176
Asadi, Mohammad; Dadfarnia, Shayessteh; Haji Shabani, Ali Mohammad; Abbasi, Bijan
2015-07-01
A novel and simple method based on solidified floating organic drop microextraction followed by high-performance liquid chromatography with ultraviolet detection has been developed for simultaneous preconcentration and determination of phenobarbital, lamotrigine, and phenytoin in human plasma and urine samples. Factors affecting microextraction efficiency such as the type and volume of the extraction solvent, sample pH, extraction time, stirring rate, extraction temperature, ionic strength, and sample volume were optimized. Under the optimum conditions (i.e. extraction solvent, 1-undecanol (40 μL); sample pH, 8.0; temperature, 25°C; stirring rate, 500 rpm; sample volume, 7 mL; potassium chloride concentration, 5% and extraction time, 50 min), the limits of detection for phenobarbital, lamotrigine, and phenytoin were 1.0, 0.1, and 0.3 μg/L, respectively. Also, the calibration curves for phenobarbital, lamotrigine, and phenytoin were linear in the concentration range of 2.0-300.0, 0.3-200.0, and 1.0-200.0 μg/L, respectively. The relative standard deviations for six replicate extractions and determinations of phenobarbital, lamotrigine, and phenytoin at 50 μg/L level were less than 4.6%. The method was successfully applied to determine phenobarbital, lamotrigine, and phenytoin in plasma and urine samples. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
The impact of BMI on sperm parameters and the metabolite changes of seminal plasma concomitantly.
Guo, Dan; Wu, Wei; Tang, Qiuqin; Qiao, Shanlei; Chen, Yiqiu; Chen, Minjian; Teng, Mengying; Lu, Chuncheng; Ding, Hongjuan; Xia, Yankai; Hu, Lingqing; Chen, Daozhen; Sha, Jiahao; Wang, Xinru
2017-07-25
The development of male infertility increased rapidly worldwide, which coinciding with the epidemic of obesity. However, the impact of weight abnormalities on sperm quality is still contestable. To assess the correlation between BMI and sperm parameters, we searched relevant articles in PubMed, Embase, Web of science, and Wanfang database published until June 2015 without language restriction. Otherwise, we also recruited some participants who attended fertility clinic as well as some general populations in this report. We performed a systematic review and meta-analysis about BMI and sperm parameters containing total sperm count, concentration, semen volume and sperm motility (overall and progressive). Metabolomic analysis of seminal plasma was performed to explore the mechanism from a new perspective. This study found standardized weighted mean differences (SMD) in sperm parameters (total sperm count, sperm concentration, and semen volume) of abnormal weight groups decreased to different degree compared to normal weight. Dose-response analysis found SMD of sperm count, sperm concentration and semen volume respectively fell 2.4%, 1.3% and 2.0% compared with normal weight for every 5-unit increase in BMI. Metabolomic analysis of seminal plasma showed that spermidine and spermine were likely to play a vital role in the spermatogenesis progress. This systematic review with meta-analysis has confirmed there was a relationship between BMI and sperm quality, suggesting obesity may be a detrimental factor of male infertility.
Hyung, Seok-Won; Piehowski, Paul D; Moore, Ronald J; Orton, Daniel J; Schepmoes, Athena A; Clauss, Therese R; Chu, Rosalie K; Fillmore, Thomas L; Brewer, Heather; Liu, Tao; Zhao, Rui; Smith, Richard D
2014-11-01
Removal of highly abundant proteins in plasma is often carried out using immunoaffinity depletion to extend the dynamic range of measurements to lower abundance species. While commercial depletion columns are available for this purpose, they generally are not applicable to limited sample quantities (<20 μL) due to low yields stemming from losses caused by nonspecific binding to the column matrix and concentration of large eluent volumes. Additionally, the cost of the depletion media can be prohibitive for larger-scale studies. Modern LC-MS instrumentation provides the sensitivity necessary to scale-down depletion methods with minimal sacrifice to proteome coverage, which makes smaller volume depletion columns desirable for maximizing sample recovery when samples are limited, as well as for reducing the expense of large-scale studies. We characterized the performance of a 346 μL column volume microscale depletion system, using four different flow rates to determine the most effective depletion conditions for ∼6-μL injections of human plasma proteins and then evaluated depletion reproducibility at the optimum flow rate condition. Depletion of plasma using a commercial 10-mL depletion column served as the control. Results showed depletion efficiency of the microscale column increased as flow rate decreased, and that our microdepletion was reproducible. In an initial application, a 600-μL sample of human cerebrospinal fluid (CSF) pooled from multiple sclerosis patients was depleted and then analyzed using reversed phase liquid chromatography-mass spectrometry to demonstrate the utility of the system for this important biofluid where sample quantities are more commonly limited.
Mine, Madisa; Nkoane, Tapologo; Sebetso, Gaseene; Sakyi, Bright; Makhaola, Kgomotso; Gaolathe, Tendani
2013-12-01
The sample requirement of 1 mL for the Roche COBAS AmpliPrep/COBAS TaqMan HIV-1 test, version 2.0 (CAP CTM HIV v2.0) limits its utility in measuring plasma HIV-1 RNA levels for small volume samples from children infected with HIV-1. Viral load monitoring is the standard of care for HIV-1-infected patients on antiretroviral therapy in Botswana. The study aimed to validate the dilution of small volume samples with phosphate buffered saline (1× PBS) when quantifying HIV-1 RNA in patient plasma. HIV RNA concentrations were determined in undiluted and diluted pairs of samples comprising panels of quality assessment standards (n=52) as well as patient samples (n=325). There was strong correlation (R(2)) of 0.98 and 0.95 within the dynamic range of the CAP CTM HIV v2.0 test between undiluted and diluted samples from quality assessment standards and patients, respectively. The difference between viral load measurements of diluted and undiluted pairs of quality assessment standards and patient samples using the Altman-Bland test showed that the 95% limits of agreement were between -0.40 Log 10 and 0.49 Log 10. This difference was within the 0.5 Log 10 which is generally considered as normal assay variation of plasma RNA levels. Dilution of samples with 1× PBS produced comparable viral load measurements to undiluted samples. Copyright © 2013 Elsevier B.V. All rights reserved.
Effects of discharge parameters on the micro-hollow cathode sustained glow discharge
NASA Astrophysics Data System (ADS)
Shoujie, HE; Peng, WANG; Jing, HA; Baoming, ZHANG; Zhao, ZHANG; Qing, LI
2018-05-01
The effects of parameters such as pressure, first anode radius, and the cavity diameter on the micro-hollow cathode sustained glow discharge are investigated by using a two-dimensional self-consistent fluid model in pure argon. The results indicate that the three parameters influence the discharge in the regions inside and outside of the cavity. Under a fixed voltage on each electrode, a larger volume of high density plasma can be produced in the region between the first and the second anodes by selecting the appropriate pressure, the higher first anode, and the appropriate cavity diameter. As the pressure increases, the electron density inside the hollow cathode, the high density plasma volume between the first anode and second anodes, and the radial electric field in the cathode cavity initially increase and subsequently decrease. As the cavity diameter increases, the high-density plasma volume between the first and second anodes initially increases and subsequently decreases; whereas the electron density inside the hollow cathode decreases. As the first anode radius increases, the electron density increases both inside and outside of the cavity. Moreover, the increase of the electron density is more obvious in the microcathode sustained region than in the micro cavity region. The results reveal that the discharge inside the cavity interacts with that outside the cavity. The strong hollow cathode effect and the high-density plasma inside the cavity favor the formation of a sustained discharge between the first anode and the second anodes. Results also show that the radial boundary conditions exert a considerably weaker influence on the discharge except for a little change in the region close to the radial boundary.
Nadar, Sunil; Blann, Andrew D; Lip, Gregory Y H
2004-01-01
Platelet abnormalities have been described in hypertension, especially in the presence of target organ damage. Our aim was to study the differences in morphology and indices of platelet activation in treatment-naive patients with essential hypertension as compared to normotensive controls and secondly, to study the effects of amlodipine-based antihypertensive therapy on these indices. We recruited 42 previously untreated, newly diagnosed hypertensive patients (25 men; mean age 53 years) for the cross-sectional study, where data were compared with those from 30 normotensive controls (20 men; mean age 57 years). Of the 42 untreated hypertensive patients who were recruited, 27 patients successfully completed, the six-month treatment phase with amlodipine-based antihypertensive therapy. Platelet morphology (volume and mass) was quantified, and plasma markers of platelet activation (betaTG and sPsel) measured in citrated plasma. The mass of P-selectin in each platelet (pPsel) was determined by lysing a fixed number of platelets and then determining the levels of P-selectin in the lysate. Hypertensive patients had significantly higher platelet volume (P = 0.01) and mass (P = 0.003), plasma betaTG and sPsel, and pPsel levels (all P < 0.001) compared to the controls. After a mean treatment time of 6 months, there was a decrease in platelet volume (P < 0.001) and mass (P = 0.02), with lower pPsel, sPsel and BTG levels (all P < 0.001) compared to the untreated state. Treatment of uncomplicated essential hypertension using amlodipine-based anti-hypertensive therapy results in a reversal of the platelet morphology abnormalities and indices of platelet activation. This may contribute to a reduction in thrombosis-related complications seen in those whose blood pressure lowering is effective.
Simon, T-P; Schuerholz, T; Haugvik, S P; Forberger, C; Burmeister, M-A; Marx, G
2013-01-01
There is evidence that suggests that early fluid resuscitation is beneficial in the treatment of sepsis. We previously demonstrated that hydroxyethyl starch (HES) 130/0.42 attenuated capillary leakage better than HES 200/0.5. Using a similar porcine fecal sepsis model, we tested the effects of two new synthetic high molecular weight (700 kDa) hydroxyethyl starches with the same molar substitution of 0.42 but with a different C2/C6 ratio compared to 6% HES 130/0.42 on plasma volume (PV), systemic and tissue oxygenation. This was a prospective, randomized, controlled animal study. Twenty-five anesthetized and mechanically ventilated pigs (28.4±2.3 kg) were observed over 8 h. Septic shock was induced with fecal peritonitis. Animals were randomized for volume-replacement therapy with HES 700/0.42 C2/C6/2.5:1 (N.=5), HES 700/0.42 C2/C6/6:1 (N.=5), HES 130/0.42 C2/C6/5:1 (N.=5) or Ringer’s Solution (RS, N.=5), and compared to non-septic controls receiving RS (N.=5). The albumin escape rate (AER) was calculated and plasma volume was determined at the end of the study. Tissue Oxygen Saturation was measured with the InSpectra™ Device (InSpectra Tissue Spectrometer, Hutchinson Technology Inc., Hutchinson, MN, USA). The AER increased in all groups compared to control. All colloids (HES 700/6:1 68±15; HES 130 67±4; HES 700/2.5:1 71±12; P<0.05) but not RS (44±7) stabilized PV (mL/kg BW) after eight hours of sepsis. Systemic oxygenation was significantly lower in the RS group (44±17%; P<0.05) compared to all other groups at study end (P<0.05). In this porcine fecal peritonitis model, the high molecular weight artificial colloids HES 700/2.5:1 and HES 700/6:1 were not more effective in maintaining plasma volume and systemic and tissue oxygenation than HES 130. In comparison to crystalloid RS, all HES solutions were more effective at maintaining plasma volume, mean arterial pressure (MAP), and systemic and tissue oxygenation.
Pressure balance inconsistency exhibited in a statistical model of magnetospheric plasma
NASA Astrophysics Data System (ADS)
Garner, T. W.; Wolf, R. A.; Spiro, R. W.; Thomsen, M. F.; Korth, H.
2003-08-01
While quantitative theories of plasma flow from the magnetotail to the inner magnetosphere typically assume adiabatic convection, it has long been understood that these convection models tend to overestimate the plasma pressure in the inner magnetosphere. This phenomenon is called the pressure crisis or the pressure balance inconsistency. In order to analyze it in a new and more detailed manner we utilize an empirical model of the proton and electron distribution functions in the near-Earth plasma sheet (-50 RE < X < -10 RE), which uses the [1989] magnetic field model and a plasma sheet representation based upon several previously published statistical studies. We compare our results to a statistically derived particle distribution function at geosynchronous orbit. In this analysis the particle distribution function is characterized by the isotropic energy invariant λ = EV2/3, where E is the particle's kinetic energy and V is the magnetic flux tube volume. The energy invariant is conserved in guiding center drift under the assumption of strong, elastic pitch angle scattering. If, in addition, loss is negligible, the phase space density f(λ) is also conserved along the same path. The statistical model indicates that f(λ, ?) is approximately independent of X for X ≤ -35 RE but decreases with increasing X for X ≥ -35 RE. The tailward gradient of f(λ, ?) might be attributed to gradient/curvature drift for large isotropic energy invariants but not for small invariants. The tailward gradient of the distribution function indicates a violation of the adiabatic drift condition in the plasma sheet. It also confirms the existence of a "number crisis" in addition to the pressure crisis. In addition, plasma sheet pressure gradients, when crossed with the gradient of flux tube volume computed from the [1989] magnetic field model, indicate Region 1 currents on the dawn and dusk sides of the outer plasma sheet.
Self-driven filter-based blood plasma separator microfluidic chip for point-of-care testing.
Madadi, Hojjat; Casals-Terré, Jasmina; Mohammadi, Mahdi
2015-05-22
There is currently a growing need for lab-on-a-chip devices for use in clinical analysis and diagnostics, especially in the area of patient care. The first step in most blood assays is plasma extraction from whole blood. This paper presents a novel, self-driven blood plasma separation microfluidic chip, which can extract more than 0.1 μl plasma from a single droplet of undiluted fresh human blood (~5 μl). This volume of blood plasma is extracted from whole blood with high purity (more than 98%) in a reasonable time frame (3 to 5 min), and without the need for any external force. This would be the first step towards the realization of a single-use, self-blood test that does not require any external force or power source to deliver and analyze a fresh whole-blood sample, in contrast to the existing time-consuming conventional blood analysis. The prototypes are manufactured in polydimethylsiloxane that has been modified with a strong nonionic surfactant (Silwet L-77) to achieve hydrophilic behavior. The main advantage of this microfluidic chip design is the clogging delay in the filtration area, which results in an increased amount of extracted plasma (0.1 μl). Moreover, the plasma can be collected in one or more 10 μm-deep channels to facilitate the detection and readout of multiple blood assays. This high volume of extracted plasma is achieved thanks to a novel design that combines maximum pumping efficiency without disturbing the red blood cells' trajectory through the use of different hydrodynamic principles, such as a constriction effect and a symmetrical filtration mode. To demonstrate the microfluidic chip's functionality, we designed and fabricated a novel hybrid microdevice that exhibits the benefits of both microfluidics and lateral flow immunochromatographic tests. The performance of the presented hybrid microdevice is validated using rapid detection of thyroid stimulating hormone within a single droplet of whole blood.
NASA Astrophysics Data System (ADS)
2010-12-01
A scientific session of the Physical Sciences Division, Russian Academy of Sciences (RAS), was held on 26 May 2010 at the conference hall of the Lebedev Physical Institute, RAS. The session was devoted to the 85th birthday of S I Syrovatskii. The program announced on the web page of the RAS Physical Sciences Division (www.gpad.ac.ru) contained the following reports: (1) Zelenyi L M (Space Research Institute, RAS, Moscow) "Current sheets and reconnection in the geomagnetic tail"; (2) Frank A G (Prokhorov General Physics Institute, RAS, Moscow) "Dynamics of current sheets as the cause of flare events in magnetized plasmas"; (3) Kuznetsov V D (Pushkov Institute of Terrestrial Magnetism, the Ionosphere, and Radio Wave Propagation, RAS, Troitsk, Moscow region) "Space research on the Sun"; (4) Somov B V (Shternberg Astronomical Institute, Lomonosov Moscow State University, Moscow) "Strong shock waves and extreme plasma states"; (5) Zybin K P (Lebedev Physical Institute, RAS, Moscow) "Structure functions for developed turbulence"; (6) Ptuskin V S (Pushkov Institute of Terrestrial Magnetism, the Ionosphere, and Radio Wave Propagation, RAS, Troitsk, Moscow region) "The origin of cosmic rays." Papers based on reports 1-4 and 6 are published in what follows. • Metastability of current sheets, L M Zelenyi, A V Artemyev, Kh V Malova, A A Petrukovich, R Nakamura Physics-Uspekhi, 2010, Volume 53, Number 9, Pages 933-941 • Dynamics of current sheets underlying flare-type events in magnetized plasmas, A G Frank Physics-Uspekhi, 2010, Volume 53, Number 9, Pages 941-947 • Space research of the Sun, V D Kuznetsov Physics-Uspekhi, 2010, Volume 53, Number 9, Pages 947-954 • Magnetic reconnection in solar flares, B V Somov Physics-Uspekhi, 2010, Volume 53, Number 9, Pages 954-958 • The origin of cosmic rays, V S Ptuskin Physics-Uspekhi, 2010, Volume 53, Number 9, Pages 958-961
NASA Technical Reports Server (NTRS)
Greenleaf, John E.
1998-01-01
After growth during adolesence, total body water decreases progressively with aging from 65% of body weight to about 53% of body weight in the 70th decade; a majority of the loss occurs from the extracellular volume, from 42% to about 25%, respectively. Cellular volume also reaches equilibrium in the 70th decade at about 25% of body weight. Various stresses such as exercise, heat and attitude exposure, ad prior dehydration attenuate voluntary fluid intake (involuntary dehydration). Voluntary fluid intake appears to decrease with aging (involuntary dehydration in this sense aging can be considered as a stress. Kidney function and muscle mass (80% water) decrease somewhat with aging, and voluntary fluid intake (thirst) is also attenuated. Thirst is stimulated by increasing osmolality (hypernatremia) of the extracellular fluid and by decreased extracellular volume (mainly plasma volume) which act to increase intracellular fluid volume osmolality to activiate drinking. The latter decreases fluid compartment osmolality which ' It terminates drinking. However, this drinking mechanism seems to be attenuated with aging such that increasing plasma osmolality no longer stimulates fluid intake appropriately. Hypernatremia in the elderly has been associated all too frequently with greater incidence of bacterial infection and increased mortality. Involuntary dehydration can be overcome in young men by acclimation to an intermittent exercise-in-heat training program. Perhaps exercise training in the elderly would also increase voluntary fluid intake and increase muscle mass to enhance retention of water.
Drug effects on orthostatic intolerance induced by bedrest
NASA Technical Reports Server (NTRS)
Vernikos, J.; Dallman, M. F.; Van Loon, G.; Keil, L. C.
1991-01-01
Effective and practical preventive procedures for postflight orthostatic intolerance are highly desirable. The current practice of attempts to expand plasma volume by ingestion of salt and fluids before reentry has proven benefits. This study evaluated alternative options using fludrocortisone (F) to expand plasma volume (PV), dextroamphetamine (Dex) to enhance norepinephrine (NE) release, and atropine (A) to reduce the effects of vagal stimulation. Seven subjects with proven post-bedrest orthostatic intolerance returned for a 7-day 6-deg head-down bedrest study. F (0.2 mg) was given at 8:00 AM and 8:00 PM the day before and 8:00 AM the day the subjects got out of bed (2 hours before standing). PV was measured before and 1 hour after the last dose of F. Dex (5 mg) and A (0.8 mg) were then taken orally 1 hour before the stand test. F expanded PV by 16 percent and caused sodium retention. Four of the 7 subjects stood for 1 hour post-bedrest and heart rate, plasma NE and plasma renin responses to standing were greatly enhanced and sustained. Although there was a narrowing of pulse pressure, the ability to overcome orthostatic intolerance with these countermeasures was largely due to vasoconstriction and sustained high heart rate.
The disposition and behavioral effects of methadone in Greyhounds.
KuKanich, Butch; Borum, Stacy L
2008-05-01
To determine the behavioral effects and pharmacokinetics of methadone in healthy Greyhounds. Prospective experimental study. Three male and three female healthy Greyhounds. Methadone hydrochloride, 0.5 mg kg(-1) IV (equivalent to 0.45 mg kg(-1) methadone base), was administered as an IV bolus. Trained observers subjectively assessed the behavioral effects of methadone. Blood samples were obtained at predetermined time points and plasma methadone concentrations were measured by liquid chromatography with tandem mass spectrometry. Pharmacokinetic variables were estimated with computer software. Methadone was well tolerated by the dogs with panting and defecation observed as adverse effects. Mild sedation was present, but no vomiting, excitement, or dysphoria was observed. The elimination half-life, volume of distribution, and plasma clearance were 1.53 +/- 0.18 hours, 7.79 +/- 1.87 L kg(-1), and 56.04 +/- 9.36 mL minute(-1) kg(-1), respectively. Methadone was well tolerated by Greyhounds. The volume of distribution was larger than expected, with resultant lower plasma concentrations than expected. Higher doses may need to be administered to Greyhounds in comparison with non-Greyhound dogs in order to achieve similar plasma drug concentrations. A dosage of 1-1.5 mg kg(-1) every 3-4 hours is suggested for future studies of analgesic efficacy of methadone in Greyhounds.
NASA Astrophysics Data System (ADS)
Piao, Linfeng; Park, Hyungmin; Jo, Chris
2016-11-01
We present a theoretical model of the recovery rate of platelet and white blood cell in the process of centrifugal separation of platelet-rich plasma (PRP). For the practically used conditions in the field, the separation process is modeled as a one-dimensional particle sedimentation; a quasi-linear partial differential equation is derived based on the kinematic-wave theory. This is solved to determine the interface positions between supernatant-suspension and suspension-sediment, used to estimate the recovery rate of the plasma. While correcting the Brown's hypothesis (1989) claiming that the platelet recovery is linearly proportional to that of plasma, we propose a new correlation model for prediction of the platelet recovery, which is a function of the volume of whole blood, centrifugal acceleration and time. For a range of practical parameters, such as hematocrit, volume of whole blood and centrifugation (time and acceleration), the predicted recovery rate shows a good agreement with available clinical data. We propose that this model is further used to optimize the preparation method of PRP that satisfies the customized case. Supported by a Grant (MPSS-CG-2016-02) through the Disaster and Safety Management Institute funded by Ministry of Public Safety and Security of Korean government.
Zelmat, Mohamed Sofiane
2015-01-01
Direct and indirect ion selective electrodes (ISEs) are two methods commonly used in biochemistry laboratories in order to measure the electrolytes such as sodium. In the clinical practice, it's the sodium concentration in plasma water -measured by direct ISE- which is important to consider as it is responsible of water movements between the liquid compartments. Knowing the difference between the two methods is important because there are situations leading to conflicting results between direct and indirect ISE, especially with sodium and inappropriate therapeutic decisions could be taken if the clinician is not aware of this difference. The increase and the decrease in plasma water volume are the situations that distort the results of the indirect ISE because this method, after a dilution step, does not take into account the real percentage of plasma water of the patient in the determination of the concentrations (leading for sodium to pseudohyponatremia, pseudonormonatremia or pseudohypernatremia). In the direct ISE, the sample is not diluted and the results are correct even if the volume of plasma water is modified. This article specifies the differences between the two techniques through a case of Waldenström's macroglobulinemia and proposes a course of action to follow for both of the biologist and the clinician.
INCREASED BLOOD VOLUME IN POLYCYTHEMIA VERA AND THE EFFECT ON IT OF TREATMENT WITH P$sup 3$$sup 2$
DOE Office of Scientific and Technical Information (OSTI.GOV)
Burger, T.; Keszthelyi, B.; Peer, J.
1961-01-01
The effect of this treatment was studied in 3 patients with polycythemia vera having hematocrits of 70-80% and red cell counts of 6-8 x 10/sup 6/. Plasma volume was also elevated and the red cell volume was decreased to 80-5 mu m/sup 3/ from a normal mean of 87. After a single injection of 3-10 mc inorganic P/sup 32/O/sub 4/, subjective symptoms improved as well as the hematologic values. Hematocrit, hemoglobin, and counts of erythrocytes, leukocytes, and thrombocytes fell. Blood volume and viscosity also declined. (H.H.D.)
High Throughput Plasma Water Treatment
NASA Astrophysics Data System (ADS)
Mujovic, Selman; Foster, John
2016-10-01
The troublesome emergence of new classes of micro-pollutants, such as pharmaceuticals and endocrine disruptors, poses challenges for conventional water treatment systems. In an effort to address these contaminants and to support water reuse in drought stricken regions, new technologies must be introduced. The interaction of water with plasma rapidly mineralizes organics by inducing advanced oxidation in addition to other chemical, physical and radiative processes. The primary barrier to the implementation of plasma-based water treatment is process volume scale up. In this work, we investigate a potentially scalable, high throughput plasma water reactor that utilizes a packed bed dielectric barrier-like geometry to maximize the plasma-water interface. Here, the water serves as the dielectric medium. High-speed imaging and emission spectroscopy are used to characterize the reactor discharges. Changes in methylene blue concentration and basic water parameters are mapped as a function of plasma treatment time. Experimental results are compared to electrostatic and plasma chemistry computations, which will provide insight into the reactor's operation so that efficiency can be assessed. Supported by NSF (CBET 1336375).
Laboratory development and testing of spacecraft diagnostics
NASA Astrophysics Data System (ADS)
Amatucci, William; Tejero, Erik; Blackwell, Dave; Walker, Dave; Gatling, George; Enloe, Lon; Gillman, Eric
2017-10-01
The Naval Research Laboratory's Space Chamber experiment is a large-scale laboratory device dedicated to the creation of large-volume plasmas with parameters scaled to realistic space plasmas. Such devices make valuable contributions to the investigation of space plasma phenomena under controlled, reproducible conditions, allowing for the validation of theoretical models being applied to space data. However, in addition to investigations such as plasma wave and instability studies, such devices can also make valuable contributions to the development and testing of space plasma diagnostics. One example is the plasma impedance probe developed at NRL. Originally developed as a laboratory diagnostic, the sensor has now been flown on a sounding rocket, is included on a CubeSat experiment, and will be included on the DoD Space Test Program's STP-H6 experiment on the International Space Station. In this talk, we will describe how the laboratory simulation of space plasmas made this development path possible. Work sponsored by the US Naval Research Laboratory Base Program.
Using Electrolyte Free Water Balance to Rationalize and Treat Dysnatremias.
Shah, Sanjeev R; Bhave, Gautam
2018-01-01
Dysnatremias or abnormalities in plasma [Na + ] are often termed disorders of water balance, an unclear physiologic concept often confused with changes in total fluid balance. However, most clinicians clearly recognize that hypertonic or hypotonic gains or losses alter plasma [Na + ], while isotonic changes do not modify plasma [Na + ]. This concept can be conceptualized as the electrolyte free water balance (EFWB), which defines the non-isotonic components of inputs and outputs to determine their effect on plasma [Na + ]. EFWB is mathematically proportional to the rate of change in plasma [Na + ] (dP Na /dt) and, therefore, is actively regulated to zero so that plasma [Na + ] remains stable at its homeostatic set point. Dysnatremias are, therefore, disorders of EFWB and the relationship between EFWB and dP Na /dt provides a rationale for therapeutic strategies incorporating mass and volume balance. Herein, we leverage dP Na /dt as a desired rate of correction of plasma [Na + ] to define a stepwise approach for the treatment of dysnatremias.
Using Electrolyte Free Water Balance to Rationalize and Treat Dysnatremias
Shah, Sanjeev R.; Bhave, Gautam
2018-01-01
Dysnatremias or abnormalities in plasma [Na+] are often termed disorders of water balance, an unclear physiologic concept often confused with changes in total fluid balance. However, most clinicians clearly recognize that hypertonic or hypotonic gains or losses alter plasma [Na+], while isotonic changes do not modify plasma [Na+]. This concept can be conceptualized as the electrolyte free water balance (EFWB), which defines the non-isotonic components of inputs and outputs to determine their effect on plasma [Na+]. EFWB is mathematically proportional to the rate of change in plasma [Na+] (dPNa/dt) and, therefore, is actively regulated to zero so that plasma [Na+] remains stable at its homeostatic set point. Dysnatremias are, therefore, disorders of EFWB and the relationship between EFWB and dPNa/dt provides a rationale for therapeutic strategies incorporating mass and volume balance. Herein, we leverage dPNa/dt as a desired rate of correction of plasma [Na+] to define a stepwise approach for the treatment of dysnatremias. PMID:29740578
Status and operation of the Linac4 ion source prototypes
NASA Astrophysics Data System (ADS)
Lettry, J.; Aguglia, D.; Andersson, P.; Bertolo, S.; Butterworth, A.; Coutron, Y.; Dallocchio, A.; Chaudet, E.; Gil-Flores, J.; Guida, R.; Hansen, J.; Hatayama, A.; Koszar, I.; Mahner, E.; Mastrostefano, C.; Mathot, S.; Mattei, S.; Midttun, Ø.; Moyret, P.; Nisbet, D.; Nishida, K.; O'Neil, M.; Ohta, M.; Paoluzzi, M.; Pasquino, C.; Pereira, H.; Rochez, J.; Sanchez Alvarez, J.; Sanchez Arias, J.; Scrivens, R.; Shibata, T.; Steyaert, D.; Thaus, N.; Yamamoto, T.
2014-02-01
CERN's Linac4 45 kV H- ion sources prototypes are installed at a dedicated ion source test stand and in the Linac4 tunnel. The operation of the pulsed hydrogen injection, RF sustained plasma, and pulsed high voltages are described. The first experimental results of two prototypes relying on 2 MHz RF-plasma heating are presented. The plasma is ignited via capacitive coupling, and sustained by inductive coupling. The light emitted from the plasma is collected by viewports pointing to the plasma chamber wall in the middle of the RF solenoid and to the plasma chamber axis. Preliminary measurements of optical emission spectroscopy and photometry of the plasma have been performed. The design of a cesiated ion source is presented. The volume source has produced a 45 keV H- beam of 16-22 mA which has successfully been used for the commissioning of the Low Energy Beam Transport (LEBT), Radio Frequency Quadrupole (RFQ) accelerator, and chopper of Linac4.
1987-08-01
B.- and Soutas. Dpmptrio; I 13a. TYPE OF REPORT 13b. TIME COVERED 114. DATE OF REPORT (Year, Month, Day) S. PAGE COUNT Final FROM84/8/20 TO 86/2/16...cages and placed in sampling boxes. At this moment a first 0.2 mL sample of blood was withdrawn. At 0 time (20 min later) another 0.2 mL sample of blood...concentration data scatter diagram (exposure group) ............. . . . . . . . . . . . . . . . 18 10. Mean plasma ACTH concentrations versus time ....... 19
Periodical plasma structures controlled by external magnetic field
NASA Astrophysics Data System (ADS)
Schweigert, I. V.; Keidar, M.
2017-06-01
The characteristics of two-dimensional periodical structures in a magnetized plasma are studied using kinetic simulations. Ridges (i.e. spikes in electron and ion density) are formed and became more pronounced with an increase of magnetic field incidence angle in the plasma volume in the cylindrical chamber. These ridges are shifted relative to each other, which results in the formation of a two-dimensional double-layer structure. Depending on Larmor radius and Debye length up to 19 potential steps appear across the oblique magnetic field. The electrical current gathered into the channels is associated with the electron and ion density ridges.
Characterization of injected aluminum oxide nanoparticle clouds in an rf discharge
NASA Astrophysics Data System (ADS)
Krüger, Harald; Killer, Carsten; Schütt, Stefan; Melzer, André
2018-02-01
An experimental setup to deagglomerate and insert nanoparticles into a radio frequency discharge has been developed to confine defined aluminum oxide nanoparticles in a dusty plasma. For the confined particle clouds we have measured the spatially resolved in situ size and density distributions. Implementing the whole plasma chamber into the sample volume of an FTIR spectrometer the infrared spectrum of the confined aluminum oxide nanoparticles has been obtained. We have investigated the dependency of the absorbance of the nanoparticles in terms of plasma power, pressure and cloud shape. The particles’ infrared phonon resonance has been identified.
Effect of physical training in cool and hot environments on +Gz acceleration tolerance in women
NASA Technical Reports Server (NTRS)
Brock, P. J.; Sciaraffa, D.; Greenleaf, J. E.
1982-01-01
Acceleration tolerance, plasma volume, and maximal oxygen uptake were measured in 15 healthy women before and after submaximal isotonic exercise training periods in cool and hot environments. The women were divided on the basis of age, maximal oxygen uptake, and +Gz tolerance into three groups: a group that exercised in heat (40.6 C), a group that exercised at a lower temperature (18.7 C), and a sedentary control group that functioned in the cool environment. There was no significant change in the +Gz tolerance in any group after training, and terminal heart rates were similar within each group. It is concluded that induction of moderate acclimation responses without increases in sweat rate or resting plasma volume has no influence on +Gz acceleration tolerance in women.
Advanced electric propulsion research - 1990
NASA Technical Reports Server (NTRS)
Monheiser, Jeffery M.; Wilbur, Paul J.
1991-01-01
An experimental study of impingement current collection on the accelerator grid of an ion thruster is presented. The equipment, instruments, and procedures being used to conduct the study are discussed. The contribution to this current due to charge-exchange ions produced close to the grid is determined using a volume-integration procedure and measured ion beam current design, computed neutral atom density and measured beam plasma potential data. This current, which is expected to be almost equal to that measured directly, is found to be an order of magnitude less. The impingement current determined by integrating the current density of ambient ions in the beam plasma close to the grid is found to agree with the directly measured impingement current. Possible reasons for the disagreement between the directly measured and volume integrated impingement currents are discussed.
NASA Astrophysics Data System (ADS)
Ruohoniemi, J. M.; Baker, J. B.; Greenwald, R. A.; Clausen, L. B.; Shepherd, S. G.; Bristow, W. A.; Talaat, E. R.; Barnes, R. J.
2010-12-01
Within the past year the first pair of SuperDARN radars funded under the NSF MSI program has become operational at a site near Hays, Kansas. The fields of view of the co-located radars are oriented to provide common-volume observations with two existing radars in Virginia (Wallops, Blackstone) and two MSI radars under construction in Oregon (Christmas Valley). The emerging mid-latitude radar chain will complement the existing SuperDARN coverage at polar cap and auroral latitudes within North America. The mid-latitude radars observe the expansion of auroral effects during disturbed periods, subauroral polarization streams, and small-scale ionospheric irregularities on the nightside that open a window on the plasma drifts and electric fields of the quiet-time subauroral ionosphere. They also measure neutral winds at mesospheric heights and the propagation of ionospheric disturbances due to the passage of atmospheric gravity waves. The new radar capabilities provide unprecedented views of ITM processes in the subauroral ionosphere with applications to studies of ionospheric electric fields, ion-neutral coupling, atmospheric tides and planetary waves, ionospheric plasma structuring and plasma instability. In this talk we describe the new capabilities and the potential for providing large-scale context for related ITM measurements over North America. We present the first high-resolution two-dimensional maps of ionospheric plasma convection at mid-latitudes as generated from common-volume observations with the Hays and Blackstone radars.
Effect of prolonged bed rest on lung volume in normal individuals
NASA Technical Reports Server (NTRS)
Beckett, W. S.; Vroman, N. B.; Nigro, D.; Thompson-Gorman, S.; Wilkerson, J. E.
1986-01-01
The effect of prolonged bed rest on the lung function was studied by measuring forced vital capacity (FVC) and total lung capacity (TLC) in normal subjects before, during, and after 11- to 12-day rest periods. It was found that both FVC and TLC increased during bed rest (compared with the ambulatory controls), while residual volume and functional residual capacity of the respiratory system did not change. It is concluded that the increase in TLC by prolonged bed rest is not dependent on alterations in plasma volume.
Schimpf, Karen J.; Meek, Claudia C.; Leff, Richard D.; Phelps, Dale L.; Schmitz, Daniel J.; Cordle, Christopher T.
2015-01-01
Inositol is a six-carbon sugar alcohol and is one of nine biologically significant isomers of hexahydroxycyclohexane. Myo-inositol is the primary biologically active form and is present in higher concentrations in the fetus and newborn than in adults. It is currently being examined for the prevention of retinopathy of prematurity in newborn preterm infants. A robust method for quantifying myo-inositol (MI), D-chiro-inositol (DCI) and 1,5-anhydro-D-sorbitol (ADS) in very small-volume (25 μL) urine, blood serum and/or plasma samples was developed. Using a multiple-column, multiple mobile phase liquid chromatographic system with electrochemical detection, the method was validated with respect to (a) selectivity, (b) accuracy/recovery, (c) precision/reproducibility, (d) sensitivity, (e) stability and (f) ruggedness. The standard curve was linear and ranged from 0.5 to 30 mg/L for each of the three analytes. Above-mentioned performance measures were within acceptable limits described in the Food and Drug Administration’s Guidance for Industry: Bioanalytical Method Validation. The method was validated using blood serum and plasma collected using four common anticoagulants, and also by quantifying the accuracy and sensitivity of MI measured in simulated urine samples recovered from preterm infant diaper systems. The method performs satisfactorily measuring the three most common inositol isomers on 25 μL clinical samples of serum, plasma milk, and/or urine. Similar performance is seen testing larger volume samples of infant formulas and infant formula ingredients. MI, ADS and DCI may be accurately tested in urine samples collected from five different preterm infant diapers if the urine volume is greater than 2–5 mL. PMID:26010453
Tajima, Yoshitaka; Suzuki, Eiji; Saito, Jun; Murase, Hiroshi; Horikawa, Yukio; Takeda, Jun
2015-01-01
Blood flow in lower extremity arteries is frequently impaired in diabetic patients even though they have a normal ankle-brachial index (ABI 1.0-1.4). Risk factors contributing to this lower extremity arterial disease have not been fully elucidated. We enrolled 52 type 2 diabetic patients with normal ABI and 30 age-matched nondiabetic subjects consecutively admitted to our hospital. Plasma B-type natriuretic peptide (BNP) concentrations were measured. Distensibility in ascending thoracic and abdominal aortas as well as total flow volume and resistive index at popliteal artery were evaluated by gated magnetic resonance imaging. An automatic device was used to measure ABI and brachial-ankle pulse-wave velocity (baPWV). Diabetic patients showed lower distensibility in ascending thoracic aorta (p<0.001) and total flow volume (p<0.001) and higher baPWV (p<0.001) and resistive index (p=0.005) and similar BNP and distensibility in abdominal aorta compared to nondiabetic subjects. Simple linear regression analyses revealed that distensibility in ascending thoracic (p=0.019) and abdominal (p=0.030) aortas positively as well as baPWV (p=0.020), resistive index (p<0.001) and BNP (p<0.001) negatively correlated with total flow volume. Stepwise multiple regression analysis demonstrated that increased BNP and resistive index were independent risk factors for total flow volume in diabetic patients (r(2)=0.639, p<0.001). These results indicate that increased plasma BNP levels and peripheral vascular resistance, but not decreased aortic distensibility, associate with impaired blood flow in lower extremity arteries in diabetic patients.
Cullen, Tom; Thomas, Andrew W; Webb, Richard; Hughes, Michael G
2016-08-01
Acute increases in interleukin (IL)-6 following prolonged exercise are associated with the induction of a transient anti-inflammatory state (e.g., increases in IL-10) that is partly responsible for the health benefits of regular exercise. The purposes of this study were to investigate the IL-6-related inflammatory response to high-intensity interval exercise (HIIE) and to determine the impact of exercise intensity and volume on this response. Ten participants (5 males and 5 females) completed 3 exercise bouts of contrasting intensity and volume (LOW, MOD, and HIGH). The HIGH protocol was based upon standard HIIE protocols, while the MOD and LOW protocols were designed to enable a comparison of exercise intensity and volume with a fixed duration. Inflammatory cytokine concentrations were measured in plasma (IL-6, IL-10) and also determined the level of gene expression (IL-6, IL-10, and IL-4R) in peripheral blood. The plasma IL-6 response to exercise (reported as fold changes) was significantly greater in HIGH (2.70 ± 1.51) than LOW (1.40 ± 0.32) (P = 0.04) and was also positively correlated to the mean exercise oxygen uptake (r = 0.54, P < 0.01). However, there was no change in anti-inflammatory IL-10 or IL-4R responses in plasma or at the level of gene expression. HIIE caused a significant increase in IL-6 and was greater than that seen in low-intensity exercise of the same duration. The increases in IL-6 were relatively small in magnitude, and appear to have been insufficient to induce the acute systemic anti-inflammatory effects, which are evident following longer duration exercise.
Porcelain-coated antenna for radio-frequency driven plasma source
Leung, K.N.; Wells, R.P.; Craven, G.E.
1996-12-24
A new porcelain-enamel coated antenna creates a clean plasma for volume or surface-conversion ion sources. The porcelain-enamel coating is hard, electrically insulating, long lasting, non fragile, and resistant to puncture by high energy ions in the plasma. Plasma and ion production using the porcelain enamel coated antenna is uncontaminated with filament or extraneous metal ions because the porcelain does not evaporate and is not sputtered into the plasma during operation. Ion beams produced using the new porcelain-enamel coated antenna are useful in ion implantation, high energy accelerators, negative, positive, or neutral beam applications, fusion, and treatment of chemical or radioactive waste for disposal. For ion implantation, the appropriate species ion beam generated with the inventive antenna will penetrate large or small, irregularly shaped conducting objects with a narrow implantation profile. 8 figs.
Plasma MRI Experiments at UW-Madison
NASA Astrophysics Data System (ADS)
Flanagan, K.; Clark, M.; Desangles, V.; Siller, R.; Wallace, J.; Weisberg, D.; Forest, C. B.
2015-11-01
Experiments for driving Keplerian-like flow profiles on both the Plasma Couette Experiment Upgrade (PCX-U) and the Wisconsin Plasma Astrophysics Laboratory (WiPAL) user facility are described. Instead of driving flow at the boundaries, as is typical in many liquid metal Couette experiments, a global drive is implemented. A large radial current is drawn across a small axial field generating torque across the whole profile. This global electrically driven flow is capable of producing profiles similar to Keplerian flow. PCX-U has been purposely constructed for MRI experiments, while similar experiments on the WiPAL device show the versatility of the user facility and provide a larger plasma volume. Numerical calculations show the predicted parameter spaces for exciting the MRI in these plasmas and the equilibrium flow profiles expected. In both devices, relevant MRI parameters appear to be within reach of typical operating characteristics.
Analysis of the plasma-wall interaction in the Heliotron E device
NASA Astrophysics Data System (ADS)
Motojima, O.; Mizuuchi, T.; Besshou, S.; Iiyoshi, A.; Uo, K.; Yamashina, T.; Mohri, M.; Satake, T.; Hashiba, M.; Amemiya, S.; Miwa, H.
1984-12-01
The plasma-wall interaction (PWI) of the currentless plasmas with temperature To, Tio ≤ 1.1 keV, density N¯e = (2-10)× 1013/cm3, and volume-averaged beta value of β$¯≤ 2% was investigated. We have observed that PWI took place mainly where the divertor field line intersected the chamber wall (called divertor traces). Boundary plasmas were measured with electrostatic probes, which showed the presence of the divertor region with the parameters in the range of Ned = 1010-1011/cm3 and Ted = 10-50 eV. Surface analysis techniques (ESCA, AES, and RBS) were applied to analyze the surface probes (Si, graphite and stainless steel) and the test pieces (SiC, TiC, and stainless steel), which were irradiated by plasmas for short and long times respectively.
Plasma convection and ion beam generation in the plasma sheet boundary layer
NASA Technical Reports Server (NTRS)
Moghaddam-Taaheri, E.; Goertz, C. K.; Smith, R. A.
1991-01-01
Because of the dawn-dusk electric field E(dd), plasma in the magnetotail convects from the lobe toward the central plasma sheet (CPS). In the absence of space or velocity diffusion due to plasma turbulence, convection would yield a steady state distribution function f = V exp (-2/3) g(v exp 2 V exp 2/3), where V is the flux tube volume. Starting with such a distribution function and a plasma beta which varies from beta greater than 1 in the CPS to beta much smaller than 1 in the lobe, the evolution of the ion distribution function was studied considering the combined effects of ion diffusion by kinetic Alfven waves (KAW) in the ULF frequency range (1-10 mHz) and convection due to E(dd) x B drift in the plasma sheet boundary layer (PSBL) and outer central plasma sheet (OCPS). The results show that, during the early stages after launching the KAWs, a beamlike ion distribution forms in the PSBL and at the same time the plasma density and temperature decrease in the OCPS. Following this stage, ions in the beams convect toward the CPS resulting in an increase of the plasma temperature in the OCPS.
Atrial natriuretic factor increases vascular permeability
NASA Technical Reports Server (NTRS)
Lockette, Warren; Brennaman, Bruce
1990-01-01
An increase in central blood volume in microgravity may result in increased plasma levels of atrial natriuretic factor (ANF). In this study, it was determined whether ANF increases capillary permeability to plasma protein. Conscious, bilaterally nephrectomized male rats were infused with either saline, ANF + saline, or hexamethonium + saline over 2 h following bolus injections of (I-125)-albumin and (C-14)-dextran of similar molecular size. Blood pressure was monitored, and serial determinations of hematocrits were made. Animals infused with 1.0 microg/kg per min ANF had significantly higher hematocrits than animals infused with saline vehicle. Infusion of ANF increased the extravasation of (I-125)-albumin, but not (C-14)-dextran from the intravascular compartment. ANF also induced a depressor response in rats, but the change in blood pressure did not account for changes in capillary permeability to albumin; similar depressor responses induced by hexamethonium were not accompanied by increased extravasation of albumin from the intravascular compartment. ANF may decrease plasma volume by increasing permeability to albumin, and this effect of ANF may account for some of the signs and symptoms of space motion sickness.
Planned Experiments on the Princeton Advanced Test Stand
NASA Astrophysics Data System (ADS)
Stepanov, A.; Gilson, E. P.; Grisham, L.; Kaganovich, I.; Davidson, R. C.
2010-11-01
The Princeton Advanced Test Stand (PATS) device is an experimental facility based on the STS-100 high voltage test stand transferred from LBNL. It consists of a multicusp RF ion source, a pulsed extraction system capable of forming high-perveance 100keV ion beams, and a large six-foot-long vacuum with convenient access for beam diagnostics. This results in a flexible system for studying high perveance ion beams relevant to NDCX-I/II, including experiments on beam neutralization by ferroelectric plasma sources (FEPS) being developed at PPPL. Research on PATS will concern the basic physics of beam-plasma interactions, such as the effects of volume neutralization on beam emittance, as well as optimizing technology of the FEPS. PATS combines the advantage of an ion beam source and a large-volume plasma source in a chamber with ample access for diagnostics, resulting in a robust setup for investigating and improving relevant aspects of neutralized drift. There are also plans for running the ion source with strongly electro-negative gases such as chlorine, making it possible to extract positive or negative ion beams.
Laser Irradiated Foam Targets: Absorption and Radiative Properties
NASA Astrophysics Data System (ADS)
Salvadori, Martina; Luigi Andreoli, Pier; Cipriani, Mattia; Consoli, Fabrizio; Cristofari, Giuseppe; De Angelis, Riccardo; di Giorgio, Giorgio; Giulietti, Danilo; Ingenito, Francesco; Gus'kov, Sergey Yu.; Rupasov, Alexander A.
2018-01-01
An experimental campaign to characterize the laser radiation absorption of foam targets and the subsequent emission of radiation from the produced plasma was carried out in the ABC facility of the ENEA Research Center in Frascati (Rome). Different targets have been used: plastic in solid or foam state and aluminum targets. The activated different diagnostics allowed to evaluate the plasma temperature, the density distribution, the fast particle spectrum and the yield of the X-Ray radiation emitted by the plasma for the different targets. These results confirm the foam homogenization action on laser-plasma interaction, mainly attributable to the volume absorption of the laser radiation propagating in such structured materials. These results were compared with simulation absorption models of the laser propagating into a foam target.
Smith, D R; Mazzucato, E; Lee, W; Park, H K; Domier, C W; Luhmann, N C
2008-12-01
A collective scattering system has been installed on the National Spherical Torus Experiment (NSTX) to measure electron gyroscale fluctuations in NSTX plasmas. The system measures fluctuations with k( perpendicular)rho(e) less, similar0.6 and k( perpendicular) less, similar20 cm(-1). Up to five distinct wavenumbers are measured simultaneously, and the large toroidal curvature of NSTX plasmas provides enhanced spatial localization. Steerable optics can position the scattering volume throughout the plasma from the magnetic axis to the outboard edge. Initial measurements indicate rich turbulent dynamics on the electron gyroscale. The system will be a valuable tool for investigating the connection between electron temperature gradient turbulence and electron thermal transport in NSTX plasmas.
NASA Technical Reports Server (NTRS)
Knapp, Charles F.; Evans, Joyce M.
1996-01-01
A major focus of our program has been to develop a sensitive noninvasive procedure to quantify early weightlessness-induced changes in cardiovascular function or potential dysfunction. Forty studies of healthy young volunteers (10 men and 10 women, each studied twice) were conducted to determine changes in the sympatho-vagal balance of autonomic control of cardiovascular regulation during graded headward and footward blood volume shifts. Changes in sympatho-vagal balance were classified by changes in the mean levels and spectral content of cardiovascular variables and verified by changes in circulating levels of catecholamines and pancreatic polypeptide. Possible shifts in intra/extravascular fluid were assessed from changes in hematocrit and plasma mass density while changes in the stimulus to regulate plasma volume were determined from Plasma Renin Activity (PRA). Autonomic blockade was used to unmask the relative contribution of sympathetic and parasympathetic efferent influences in response to 10 min each of 0, 20 and 40 mmHg Lower Body Negative Pressure (LBNP) and 15 and 30 mmHg Positive Pressure (LBPP). The combination of muscarinic blockade with graded LBNP and LBPP was used to evoke graded increases and decreases in sympathetic activity without parasympathetic contributions. The combination of beta blockade with graded LBNP and LBPP was used to produce graded increases and decreases in parasympathetic activity without beta sympathetic contributions. Finally, a combination of both beta and muscarinic blockades with LBNP and LBPP was used to determine the contribution from other, primarily alpha adrenergic, sources. Mean values, spectral analyses and time frequency analysis of R-R interval (HR), Arterial Pressure (AP), peripheral blood flow (RF), Stroke Volume (SV) and peripheral resistance (TPR) were performed for all phases of the study. Skin blood Flow (SF) was also measured in other studies and similarly analyzed. Spectra were examined for changes in three frequency regions (low 0.006 - 0.005 Hz (LF), mid 0.05 - 0.15 Hz (W), and high 0.15 - 0.45 Hz (EF)). The primary objective of the study was to indicate which changes in the mean values and/or spectra of cardiovascular variables consistently correlated with changes in sympatho-vagal balance in response to headward and footward fluid shifts. A secondaey objective was to quantify the vascular and extravascular fluid shifts evoked by LBNP and LBPP. The principal hypothesis being tested was that headward fluid shifts would evoke an increase in parasympathetic activity and footward fluid shifts would evoke an increase in sympathetic activity both of which would be detected by spectral analysis and verified by circulating hormones. Hematocrit (HCT), plasma mass density and plasma renin activity increased with muscarinic blockade and with LBNP, a response indicative of a plasma shift to extravascular spaces. Beta blockade alone or after muscarinic blockade had no effect on HCT or plasma mass density. With respect to intravascular fluid volume distribution, LBNP and LBPP produced sufficient upper body vascular fluid shifts to evoke appropriate autonomic regulatory responses.
Bacteria-killing ability of fresh blood plasma compared to frozen blood plasma
Jacobs, Anne C.; Fair, Jeanne Marie
2015-10-09
In recent years, the bacteria-killing assay (BKA) has become a popular technique among ecoimmunologists. New variations of that assay allow researchers to use smaller volumes of blood, an important consideration for those working on small-bodied animals. However, this version of the assay requires access to a lab with a nanodrop spectrophotometer, something that may not be available in the field. One possible solution is to freeze plasma for transport; however, this assumes that frozen plasma samples will give comparable results to fresh ones. Here, we tested this assumption using plasma samples from three species of birds: chickens (Gallus gallus), ash-throatedmore » flycatchers (Myiarchus cinerascens), and western bluebirds (Sialia mexicana). Chicken plasma samples lost most or all of their bacterial killing ability after freezing. This did not happen in flycatchers and bluebirds; however, frozen plasma did not produce results comparable to those obtained using fresh plasma. Finally, we caution researchers using the BKA to use fresh samples whenever possible, and to validate the use of frozen samples on a species-by-species basis.« less
Transition Region Emission and the Energy Input to Thermal Plasma in Solar Flares
NASA Technical Reports Server (NTRS)
Holman, Gordon D.; Holman, Gordon D.; Dennis, Brian R.; Haga, Leah; Raymond, John C.; Panasyuk, Alexander
2005-01-01
Understanding the energetics of solar flares depends on obtaining reliable determinations of the energy input to flare plasma. X-ray observations of the thermal bremsstrahlung from hot flare plasma provide temperatures and emission measures which, along with estimates of the plasma volume, allow the energy content of this hot plasma to be computed. However, if thermal energy losses are significant or if significant energy goes directly into cooler plasma, this is only a lower limit on the total energy injected into thermal plasma during the flare. We use SOHO UVCS observations of O VI flare emission scattered by coronal O VI ions to deduce the flare emission at transition region temperatures between 100,000 K and 1 MK for the 2002 July 23 and other flares. We find that the radiated energy at these temperatures significantly increases the deduced energy input to the thermal plasma, but by an amount that is less than the uncertainty in the computed energies. Comparisons of computed thermal and nonthermal electron energies deduced from RHESSI, GOES, and UVCS are shown.
Bacteria-killing ability of fresh blood plasma compared to frozen blood plasma.
Jacobs, Anne C; Fair, Jeanne M
2016-01-01
In recent years, the bacteria-killing assay (BKA) has become a popular technique among ecoimmunologists. New variations of that assay allow researchers to use smaller volumes of blood, an important consideration for those working on small-bodied animals. However, this version of the assay requires access to a lab with a nanodrop spectrophotometer, something that may not be available in the field. One possible solution is to freeze plasma for transport; however, this assumes that frozen plasma samples will give comparable results to fresh ones. We tested this assumption using plasma samples from three species of birds: chickens (Gallus gallus), ash-throated flycatchers (Myiarchus cinerascens), and western bluebirds (Sialia mexicana). Chicken plasma samples lost most or all of their bacterial killing ability after freezing. This did not happen in flycatchers and bluebirds; however, frozen plasma did not produce results comparable to those obtained using fresh plasma. We caution researchers using the BKA to use fresh samples whenever possible, and to validate the use of frozen samples on a species-by-species basis. Copyright © 2015 Elsevier Inc. All rights reserved.
Large area atmospheric-pressure plasma jet
Selwyn, Gary S.; Henins, Ivars; Babayan, Steve E.; Hicks, Robert F.
2001-01-01
Large area atmospheric-pressure plasma jet. A plasma discharge that can be operated at atmospheric pressure and near room temperature using 13.56 MHz rf power is described. Unlike plasma torches, the discharge produces a gas-phase effluent no hotter than 250.degree. C. at an applied power of about 300 W, and shows distinct non-thermal characteristics. In the simplest design, two planar, parallel electrodes are employed to generate a plasma in the volume therebetween. A "jet" of long-lived metastable and reactive species that are capable of rapidly cleaning or etching metals and other materials is generated which extends up to 8 in. beyond the open end of the electrodes. Films and coatings may also be removed by these species. Arcing is prevented in the apparatus by using gas mixtures containing He, which limits ionization, by using high flow velocities, and by properly spacing the rf-powered electrode. Because of the atmospheric pressure operation, there is a negligible density of ions surviving for a sufficiently long distance beyond the active plasma discharge to bombard a workpiece, unlike the situation for low-pressure plasma sources and conventional plasma processing methods.
Bacteria-killing ability of fresh blood plasma compared to frozen blood plasma
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jacobs, Anne C.; Fair, Jeanne Marie
In recent years, the bacteria-killing assay (BKA) has become a popular technique among ecoimmunologists. New variations of that assay allow researchers to use smaller volumes of blood, an important consideration for those working on small-bodied animals. However, this version of the assay requires access to a lab with a nanodrop spectrophotometer, something that may not be available in the field. One possible solution is to freeze plasma for transport; however, this assumes that frozen plasma samples will give comparable results to fresh ones. Here, we tested this assumption using plasma samples from three species of birds: chickens (Gallus gallus), ash-throatedmore » flycatchers (Myiarchus cinerascens), and western bluebirds (Sialia mexicana). Chicken plasma samples lost most or all of their bacterial killing ability after freezing. This did not happen in flycatchers and bluebirds; however, frozen plasma did not produce results comparable to those obtained using fresh plasma. Finally, we caution researchers using the BKA to use fresh samples whenever possible, and to validate the use of frozen samples on a species-by-species basis.« less
NASA Astrophysics Data System (ADS)
Kaur, M.; Barbano, L. J.; Suen-Lewis, E. M.; Shrock, J. E.; Light, A. D.; Schaffner, D. A.; Brown, M. B.; Woodruff, S.; Meyer, T.
2018-02-01
We have explored the thermodynamics of compressed magnetized plasmas in laboratory experiments and we call these studies `magnetothermodynamics'. The experiments are carried out in the Swarthmore Spheromak eXperiment device. In this device, a magnetized plasma source is located at one end and at the other end, a closed conducting can is installed. We generate parcels of magnetized plasma and observe their compression against the end wall of the conducting cylinder. The plasma parameters such as plasma density, temperature and magnetic field are measured during compression using HeNe laser interferometry, ion Doppler spectroscopy and a linear probe array, respectively. To identify the instances of ion heating during compression, a PV diagram is constructed using measured density, temperature and a proxy for the volume of the magnetized plasma. Different equations of state are analysed to evaluate the adiabatic nature of the compressed plasma. A three-dimensional resistive magnetohydrodynamic code (NIMROD) is employed to simulate the twisted Taylor states and shows stagnation against the end wall of the closed conducting can. The simulation results are consistent to what we observe in our experiments.
Farimani Sanoee, Marzieh; Neghab, Nosrat; Rabiee, Soghra; Amiri, Iraj
2011-01-01
Background: It is well known that there is a close relationship between elevated androgen plasma levels and the ultrasound findings of stromal hypertrophy in polycystic ovary syndrome (PCOS). The objective of this study was to investigate the effects metformin on the hyperandrogenism and ovarian volume in PCOS. Methods: The study is an unrandomized clinical trial with before–after design. Twenty eight patients with infertility (male or female factor) meeting the Rotterdam ESHRE/ASRM criteria for PCOS were studied during the 2008-2009. The anthropometric characteristics of the patients, mean bilateral ovarian volume, and morphology by trans vaginal sonography as well as the plasma levels of leutinizing hormone, follicle stimulating hormone, estradiol, testosterone, 17-α-hydroxyprogesterone, and dehydroepianderosterone sulfate were obtained before and after treatment with metformin (500 mg three times a day) for three months. Paired t, Pearson's Correlation Coefficient, or Partial Correlation test was used to analyze the findings. Results: The patients had a mean age of 25.67 years. A significant reduction in mean ovarian volume (11.70±4.31 ml vs 8.27±3.71 ml P=0.001), body mass index (BMI, 28.11±4.55 kg/m2 vs 26.84±4.55 kg/m2 P=0.000) and serum androgen levels was seen after three months of treatment with metformin. There was positive correlations between the ovarian volume and serum testosterone level (r=0.589, P=0.001) or BMI (r=0.663, P=0.000). Conclusion: Metformin therapy may lead to a reduction in ovarian volume. It is likely that the reduction of ovarian volume reflect a decrease in the mass of androgen producing tissues. Trial Registration Number: IRCT138903244176N1 PMID:23358726
[Characteristic of sample banks isolated from EDTA-blood by sedimentation method].
Chen, Zhi-bin; Lin, Qin; Ma, Chang-hua; Liu, Kai-ning; Meng, Huan-xin
2014-02-18
To assess the characteristics of establishing the different sample banks of plasma, leukocytes and DNA by sedimentation method of isolating from ethylene diamine tetraacetic acid(EDTA)-blood and to clarify the sedimentation method of leukocyte isolation and plasma volume by comparative data and recommended procedures for applicability. In the study, 29 EDTA-bloods were obtained, the total amounts of leukocytes and the percentage of neutrophile granulocytes, and lymphocytes in the EDTA-blood detected as a control group and then assigned equally into 4 EP tubes with 1 mL EDTA-blood per tube as 4 test groups, then the 4 tubes were placed with the EDTA-blood at room temperature and the plasma layers were isolated at 0.5, 1, 2 and 3 h, receptively. The total amount of leukocytes and the percentage of neutrophile granulocytes, and lymphocytes were detected by automated hematology analyzer at the clinical laboratory. The volume of the plasma was also measured at the same time. The plasma volume at 0.5 h [(241.72 ± 101.52)μL] was substantially lower than those at 1 h[(317.24 ± 97.50)μL], at 2 h[(371.03 ± 91.66)μL], and at 3 h [(408.97 ± 97.43)μL] , P < 0.05. The plasma volume at 1 h was substantially lower than those at 2 h and 3 h (P < 0.05). The total amount of leukocytes in the plasma layer at 0.5 h (2.50 × 10(6) ± 1.48 × 10(6)) group was substantially higher than the amount of 2 or 3 h groups respectively (1.47 × 10(6) ± 7.19 × 105,1.21 × 10(6) ± 7.41 × 105), P < 0.05. Significant difference was not found between 0.5 h group and 1 h group (2.29 × 10(6)± 1.17 × 10(6)), P > 0.05. The total amount of leukocytes in the plasma layer in 1 h group was substantially higher than that in 2 h and 3 h groups (P < 0.05). There was no significant difference between 3 h group and 2 h group (P > 0.05). The total amount of leukocytes in the plasma layer of the 4 test groups was substantially lower than that in the control group (P < 0.05). The percentage of neutrophile granulocytes (54.14% ± 11.65%) in the plasma layer in 0.5 h group was substantially higher than those in 1 h, 2 h and 3 h groups (46.66% ± 12.70%,39.17% ± 12.33%,43.25% ± 14.54%), P < 0.05, respectively, which was the substantially lower than that in the control group (60.53% ± 8.46%), P < 0.05. The average value of the percentage of neutrophile granulocytes in the plasma layer in 1 h group was substantially higher than that in 2 h group (P < 0.05). There was no significant different between 3 h group and both 1 h, 2 h groups (P > 0.05). The mean percentage of lymphocytes in the plasma layer in 0.5 h group (35.09% ± 10.84%) was substantially lower than those in the plasma layer in 1 h, 2 h and 3 h groups, respectively ( 41.48% ± 12.20%, 47.96% ± 12.27%, 45.50% ± 13.71%), which was significant higher than that in the control group(30.98% ± 7.33%), P < 0.05. The average value of the percentage of lymphocytes in the plasma layer in 1 h group was substantially higher than those in the control group and 0.5 h group, but was substantially lower than those in 2 h and 3 h groups (P < 0.05). The average value of percentage of lymphocytes in the plasma layer in 2 h group was substantially higher than those in the control group, 0.5 h and 1 h groups (P < 0.05). There was no significant difference between 2 h and 3 h groups (P > 0.05). The best period of time in obtaining leukocytes is 0.5-1 h sedimentation of EDTA-blood. Both the plasma layer and leukocytes can be separated and obtained at the same time from the same sample by the sedimentation method of EDTA-blood. The sedimentation of EDTA-blood has the least interference of both chemical and physical factors, as well as a ready operation, which can establish the plasma, leukocytes and DNA sample banks for various aspects of research.
NASA Astrophysics Data System (ADS)
Lazic, V.; Laserna, J. J.; Jovicevic, S.
2013-04-01
Influence of time delay between two laser pulses on the LIBS (laser induced breakdown spectroscopy) signal inside liquids was investigated and the results are compared with data from literature. Plasma was produced by laser ablation (LA) of aluminum inside water and its emission after the second laser pulse was characterized by spectrally and time resolved detection. Light propagation through the vapor bubble formed by the first laser pulse was studied by measurements of beam scattering and transmission. Optical absorption by the evolving bubble is not significant, but its growth is accompanied by lowering of its refraction index nb with respect to surrounding liquid; this effect increases defocusing both of the incident beam and of the out-coming plasma radiation. Collection efficiency of the secondary plasma emission rapidly degrades with the cavity growth, but close to its full expansion the LIBS signal partially recovers through Snell's reflections at the liquid-vapor interface, which produce a bright spot close to the bubble center. Such a light redistribution allows detecting of the emission from external plasma volume, otherwise deflected out of the collection system. Except for strong line transitions from the main sample constituents, self-absorbed inside the high-pressure cavity, we observed the highest LIBS signal when sending the second pulse well before the bubble is fully expanded. Transitions of the pressure wave through the focal volume, formed by the first laser pulse and reflected from the cell's walls and sample back-plane, enhances the LIBS signal importantly. The measured lifetime of the secondary plasma rapidly decreases with the bubble expansion. Here, we also discuss the optimization of the optical collection system and some analytical aspects of double-pulse (DP) LIBS inside liquids.
The appearance and propagation of filaments in the private flux region in Mega Amp Spherical Tokamak
DOE Office of Scientific and Technical Information (OSTI.GOV)
Harrison, J. R.; Fishpool, G. M.; Thornton, A. J.
2015-09-15
The transport of particles via intermittent filamentary structures in the private flux region (PFR) of plasmas in the MAST tokamak has been investigated using a fast framing camera recording visible light emission from the volume of the lower divertor, as well as Langmuir probes and IR thermography monitoring particle and power fluxes to plasma-facing surfaces in the divertor. The visible camera data suggest that, in the divertor volume, fluctuations in light emission above the X-point are strongest in the scrape-off layer (SOL). Conversely, in the region below the X-point, it is found that these fluctuations are strongest in the PFRmore » of the inner divertor leg. Detailed analysis of the appearance of these filaments in the camera data suggests that they are approximately circular, around 1–2 cm in diameter, but appear more elongated near the divertor target. The most probable toroidal quasi-mode number is between 2 and 3. These filaments eject plasma deeper into the private flux region, sometimes by the production of secondary filaments, moving at a speed of 0.5–1.0 km/s. Probe measurements at the inner divertor target suggest that the fluctuations in the particle flux to the inner target are strongest in the private flux region, and that the amplitude and distribution of these fluctuations are insensitive to the electron density of the core plasma, auxiliary heating and whether the plasma is single-null or double-null. It is found that the e-folding width of the time-average particle flux in the PFR decreases with increasing plasma current, but the fluctuations appear to be unaffected. At the outer divertor target, the fluctuations in particle and power fluxes are strongest in the SOL.« less
Carmo, Ana Paula Barbosa do; Borborema, Manoella; Ribeiro, Stephan; De-Oliveira, Ana Cecilia Xavier; Paumgartten, Francisco Jose Roma; Moreira, Davyson de Lima
2017-01-01
Primaquine (PQ) diphosphate is an 8-aminoquinoline antimalarial drug with unique therapeutic properties. It is the only drug that prevents relapses of Plasmodium vivax or Plasmodium ovale infections. In this study, a fast, sensitive, cost-effective, and robust method for the extraction and high-performance liquid chromatography with diode array ultraviolet detection (HPLC-DAD-UV ) analysis of PQ in the blood plasma was developed and validated. After plasma protein precipitation, PQ was obtained by liquid-liquid extraction and analyzed by HPLC-DAD-UV with a modified-silica cyanopropyl column (250mm × 4.6mm i.d. × 5μm) as the stationary phase and a mixture of acetonitrile and 10mM ammonium acetate buffer (pH = 3.80) (45:55) as the mobile phase. The flow rate was 1.0mL·min-1, the oven temperature was 50OC, and absorbance was measured at 264nm. The method was validated for linearity, intra-day and inter-day precision, accuracy, recovery, and robustness. The detection (LOD) and quantification (LOQ) limits were 1.0 and 3.5ng·mL-1, respectively. The method was used to analyze the plasma of female DBA-2 mice treated with 20mg.kg-1 (oral) PQ diphosphate. By combining a simple, low-cost extraction procedure with a sensitive, precise, accurate, and robust method, it was possible to analyze PQ in small volumes of plasma. The new method presents lower LOD and LOQ limits and requires a shorter analysis time and smaller plasma volumes than those of previously reported HPLC methods with DAD-UV detection. The new validated method is suitable for kinetic studies of PQ in small rodents, including mouse models for the study of malaria.